WorldWideScience

Sample records for hand vein recognition

  1. Personal authentication through dorsal hand vein patterns

    Science.gov (United States)

    Hsu, Chih-Bin; Hao, Shu-Sheng; Lee, Jen-Chun

    2011-08-01

    Biometric identification is an emerging technology that can solve security problems in our networked society. A reliable and robust personal verification approach using dorsal hand vein patterns is proposed in this paper. The characteristic of the approach needs less computational and memory requirements and has a higher recognition accuracy. In our work, the near-infrared charge-coupled device (CCD) camera is adopted as an input device for capturing dorsal hand vein images, it has the advantages of the low-cost and noncontact imaging. In the proposed approach, two finger-peaks are automatically selected as the datum points to define the region of interest (ROI) in the dorsal hand vein images. The modified two-directional two-dimensional principal component analysis, which performs an alternate two-dimensional PCA (2DPCA) in the column direction of images in the 2DPCA subspace, is proposed to exploit the correlation of vein features inside the ROI between images. The major advantage of the proposed method is that it requires fewer coefficients for efficient dorsal hand vein image representation and recognition. The experimental results on our large dorsal hand vein database show that the presented schema achieves promising performance (false reject rate: 0.97% and false acceptance rate: 0.05%) and is feasible for dorsal hand vein recognition.

  2. Finger vein recognition with personalized feature selection.

    Science.gov (United States)

    Xi, Xiaoming; Yang, Gongping; Yin, Yilong; Meng, Xianjing

    2013-08-22

    Finger veins are a promising biometric pattern for personalized identification in terms of their advantages over existing biometrics. Based on the spatial pyramid representation and the combination of more effective information such as gray, texture and shape, this paper proposes a simple but powerful feature, called Pyramid Histograms of Gray, Texture and Orientation Gradients (PHGTOG). For a finger vein image, PHGTOG can reflect the global spatial layout and local details of gray, texture and shape. To further improve the recognition performance and reduce the computational complexity, we select a personalized subset of features from PHGTOG for each subject by using the sparse weight vector, which is trained by using LASSO and called PFS-PHGTOG. We conduct extensive experiments to demonstrate the promise of the PHGTOG and PFS-PHGTOG, experimental results on our databases show that PHGTOG outperforms the other existing features. Moreover, PFS-PHGTOG can further boost the performance in comparison with PHGTOG.

  3. Finger Vein Recognition with Personalized Feature Selection

    Directory of Open Access Journals (Sweden)

    Xianjing Meng

    2013-08-01

    Full Text Available Finger veins are a promising biometric pattern for personalized identification in terms of their advantages over existing biometrics. Based on the spatial pyramid representation and the combination of more effective information such as gray, texture and shape, this paper proposes a simple but powerful feature, called Pyramid Histograms of Gray, Texture and Orientation Gradients (PHGTOG. For a finger vein image, PHGTOG can reflect the global spatial layout and local details of gray, texture and shape. To further improve the recognition performance and reduce the computational complexity, we select a personalized subset of features from PHGTOG for each subject by using the sparse weight vector, which is trained by using LASSO and called PFS-PHGTOG. We conduct extensive experiments to demonstrate the promise of the PHGTOG and PFS-PHGTOG, experimental results on our databases show that PHGTOG outperforms the other existing features. Moreover, PFS-PHGTOG can further boost the performance in comparison with PHGTOG.

  4. SIFT Based Vein Recognition Models: Analysis and Improvement

    Directory of Open Access Journals (Sweden)

    Guoqing Wang

    2017-01-01

    Full Text Available Scale-Invariant Feature Transform (SIFT is being investigated more and more to realize a less-constrained hand vein recognition system. Contrast enhancement (CE, compensating for deficient dynamic range aspects, is a must for SIFT based framework to improve the performance. However, evidence of negative influence on SIFT matching brought by CE is analysed by our experiments. We bring evidence that the number of extracted keypoints resulting by gradient based detectors increases greatly with different CE methods, while on the other hand the matching result of extracted invariant descriptors is negatively influenced in terms of Precision-Recall (PR and Equal Error Rate (EER. Rigorous experiments with state-of-the-art and other CE adopted in published SIFT based hand vein recognition system demonstrate the influence. What is more, an improved SIFT model by importing the kernel of RootSIFT and Mirror Match Strategy into a unified framework is proposed to make use of the positive keypoints change and make up for the negative influence brought by CE.

  5. Image Quality Enhancement Using the Direction and Thickness of Vein Lines for Finger-Vein Recognition

    OpenAIRE

    Park, Young Ho; Park, Kang Ryoung

    2012-01-01

    On the basis of the increased emphasis placed on the protection of privacy, biometric recognition systems using physical or behavioural characteristics such as fingerprints, facial characteristics, iris and finger‐vein patterns or the voice have been introduced in applications including door access control, personal certification, Internet banking and ATM machines. Among these, finger‐vein recognition is advantageous in that it involves the use of inexpensive and small devices that are diffic...

  6. Image Quality Enhancement Using the Direction and Thickness of Vein Lines for Finger-Vein Recognition

    Directory of Open Access Journals (Sweden)

    Young Ho Park

    2012-10-01

    Full Text Available On the basis of the increased emphasis placed on the protection of privacy, biometric recognition systems using physical or behavioural characteristics such as fingerprints, facial characteristics, iris and finger-vein patterns or the voice have been introduced in applications including door access control, personal certification, Internet banking and ATM machines. Among these, finger-vein recognition is advantageous in that it involves the use of inexpensive and small devices that are difficult to counterfeit. In general, finger-vein recognition systems capture images by using near infrared (NIR illumination in conjunction with a camera. However, such systems can face operational difficulties, since the scattering of light from the skin can make capturing a clear image difficult. To solve this problem, we proposed new image quality enhancement method that measures the direction and thickness of vein lines. This effort represents novel research in four respects. First, since vein lines are detected in input images based on eight directional profiles of a grey image instead of binarized images, the detection error owing to the non-uniform illumination of the finger area can be reduced. Second, our method adaptively determines a Gabor filter for the optimal direction and width on the basis of the estimated direction and thickness of a detected vein line. Third, by applying this optimized Gabor filter, a clear vein image can be obtained. Finally, the further processing of the morphological operation is applied in the Gabor filtered image and the resulting image is combined with the original one, through which finger-vein image of a higher quality is obtained. Experimental results from application of our proposed image enhancement method show that the equal error rate (EER of finger-vein recognition decreases to approximately 0.4% in the case of a local binary pattern-based recognition and to approximately 0.3% in the case of a wavelet transform

  7. Spoof Detection for Finger-Vein Recognition System Using NIR Camera

    Directory of Open Access Journals (Sweden)

    Dat Tien Nguyen

    2017-10-01

    Full Text Available Finger-vein recognition, a new and advanced biometrics recognition method, is attracting the attention of researchers because of its advantages such as high recognition performance and lesser likelihood of theft and inaccuracies occurring on account of skin condition defects. However, as reported by previous researchers, it is possible to attack a finger-vein recognition system by using presentation attack (fake finger-vein images. As a result, spoof detection, named as presentation attack detection (PAD, is necessary in such recognition systems. Previous attempts to establish PAD methods primarily focused on designing feature extractors by hand (handcrafted feature extractor based on the observations of the researchers about the difference between real (live and presentation attack finger-vein images. Therefore, the detection performance was limited. Recently, the deep learning framework has been successfully applied in computer vision and delivered superior results compared to traditional handcrafted methods on various computer vision applications such as image-based face recognition, gender recognition and image classification. In this paper, we propose a PAD method for near-infrared (NIR camera-based finger-vein recognition system using convolutional neural network (CNN to enhance the detection ability of previous handcrafted methods. Using the CNN method, we can derive a more suitable feature extractor for PAD than the other handcrafted methods using a training procedure. We further process the extracted image features to enhance the presentation attack finger-vein image detection ability of the CNN method using principal component analysis method (PCA for dimensionality reduction of feature space and support vector machine (SVM for classification. Through extensive experimental results, we confirm that our proposed method is adequate for presentation attack finger-vein image detection and it can deliver superior detection results compared

  8. Spoof Detection for Finger-Vein Recognition System Using NIR Camera.

    Science.gov (United States)

    Nguyen, Dat Tien; Yoon, Hyo Sik; Pham, Tuyen Danh; Park, Kang Ryoung

    2017-10-01

    Finger-vein recognition, a new and advanced biometrics recognition method, is attracting the attention of researchers because of its advantages such as high recognition performance and lesser likelihood of theft and inaccuracies occurring on account of skin condition defects. However, as reported by previous researchers, it is possible to attack a finger-vein recognition system by using presentation attack (fake) finger-vein images. As a result, spoof detection, named as presentation attack detection (PAD), is necessary in such recognition systems. Previous attempts to establish PAD methods primarily focused on designing feature extractors by hand (handcrafted feature extractor) based on the observations of the researchers about the difference between real (live) and presentation attack finger-vein images. Therefore, the detection performance was limited. Recently, the deep learning framework has been successfully applied in computer vision and delivered superior results compared to traditional handcrafted methods on various computer vision applications such as image-based face recognition, gender recognition and image classification. In this paper, we propose a PAD method for near-infrared (NIR) camera-based finger-vein recognition system using convolutional neural network (CNN) to enhance the detection ability of previous handcrafted methods. Using the CNN method, we can derive a more suitable feature extractor for PAD than the other handcrafted methods using a training procedure. We further process the extracted image features to enhance the presentation attack finger-vein image detection ability of the CNN method using principal component analysis method (PCA) for dimensionality reduction of feature space and support vector machine (SVM) for classification. Through extensive experimental results, we confirm that our proposed method is adequate for presentation attack finger-vein image detection and it can deliver superior detection results compared to CNN

  9. Biometric identification using infrared dorsum hand vein images

    Directory of Open Access Journals (Sweden)

    Óscar Fernando Motato Toro

    2009-01-01

    Full Text Available The evident need for improving access and safety controls has orientated the development of new personal identification systems towards using biometric, physiological and behavioral features guaranteeing increasing greater levels of performance. Motivated by this trend, the development and implementation of a computational tool for recording and validating people’s identity using dorsum hand vein images is presented here. A low-cost hardware module for acquiring infrared images was thus designed; it consisted of a conventional video-camera, optical lenses, controlled infrared illumination sources and a frame grabber. The accompanying software module was concerned with visualizing and capturing images, selecting regions of interest, pattern seg-mentation in the region and extracting, describing and classifying these features. An artificial neuron network approach was im-plemented for pattern recognition, resulting in it proving the biometric indicator to be sufficiently discriminating, and a corre-lation-based approach using a 100 image database for static characterisation, determined the system’s maximum efficiency to be 95.72% at a threshold equal to 65. False acceptance rate (FAR was 8.57% and false rejection rate (FRR was 0% at this threshold.

  10. Finger Vein Recognition Based on Local Directional Code

    Science.gov (United States)

    Meng, Xianjing; Yang, Gongping; Yin, Yilong; Xiao, Rongyang

    2012-01-01

    Finger vein patterns are considered as one of the most promising biometric authentication methods for its security and convenience. Most of the current available finger vein recognition methods utilize features from a segmented blood vessel network. As an improperly segmented network may degrade the recognition accuracy, binary pattern based methods are proposed, such as Local Binary Pattern (LBP), Local Derivative Pattern (LDP) and Local Line Binary Pattern (LLBP). However, the rich directional information hidden in the finger vein pattern has not been fully exploited by the existing local patterns. Inspired by the Webber Local Descriptor (WLD), this paper represents a new direction based local descriptor called Local Directional Code (LDC) and applies it to finger vein recognition. In LDC, the local gradient orientation information is coded as an octonary decimal number. Experimental results show that the proposed method using LDC achieves better performance than methods using LLBP. PMID:23202194

  11. Finger Vein Recognition Based on Local Directional Code

    Directory of Open Access Journals (Sweden)

    Rongyang Xiao

    2012-11-01

    Full Text Available Finger vein patterns are considered as one of the most promising biometric authentication methods for its security and convenience. Most of the current available finger vein recognition methods utilize features from a segmented blood vessel network. As an improperly segmented network may degrade the recognition accuracy, binary pattern based methods are proposed, such as Local Binary Pattern (LBP, Local Derivative Pattern (LDP and Local Line Binary Pattern (LLBP. However, the rich directional information hidden in the finger vein pattern has not been fully exploited by the existing local patterns. Inspired by the Webber Local Descriptor (WLD, this paper represents a new direction based local descriptor called Local Directional Code (LDC and applies it to finger vein recognition. In LDC, the local gradient orientation information is coded as an octonary decimal number. Experimental results show that the proposed method using LDC achieves better performance than methods using LLBP.

  12. Contact-free palm-vein recognition based on local invariant features.

    Directory of Open Access Journals (Sweden)

    Wenxiong Kang

    Full Text Available Contact-free palm-vein recognition is one of the most challenging and promising areas in hand biometrics. In view of the existing problems in contact-free palm-vein imaging, including projection transformation, uneven illumination and difficulty in extracting exact ROIs, this paper presents a novel recognition approach for contact-free palm-vein recognition that performs feature extraction and matching on all vein textures distributed over the palm surface, including finger veins and palm veins, to minimize the loss of feature information. First, a hierarchical enhancement algorithm, which combines a DOG filter and histogram equalization, is adopted to alleviate uneven illumination and to highlight vein textures. Second, RootSIFT, a more stable local invariant feature extraction method in comparison to SIFT, is adopted to overcome the projection transformation in contact-free mode. Subsequently, a novel hierarchical mismatching removal algorithm based on neighborhood searching and LBP histograms is adopted to improve the accuracy of feature matching. Finally, we rigorously evaluated the proposed approach using two different databases and obtained 0.996% and 3.112% Equal Error Rates (EERs, respectively, which demonstrate the effectiveness of the proposed approach.

  13. Contact-free palm-vein recognition based on local invariant features.

    Science.gov (United States)

    Kang, Wenxiong; Liu, Yang; Wu, Qiuxia; Yue, Xishun

    2014-01-01

    Contact-free palm-vein recognition is one of the most challenging and promising areas in hand biometrics. In view of the existing problems in contact-free palm-vein imaging, including projection transformation, uneven illumination and difficulty in extracting exact ROIs, this paper presents a novel recognition approach for contact-free palm-vein recognition that performs feature extraction and matching on all vein textures distributed over the palm surface, including finger veins and palm veins, to minimize the loss of feature information. First, a hierarchical enhancement algorithm, which combines a DOG filter and histogram equalization, is adopted to alleviate uneven illumination and to highlight vein textures. Second, RootSIFT, a more stable local invariant feature extraction method in comparison to SIFT, is adopted to overcome the projection transformation in contact-free mode. Subsequently, a novel hierarchical mismatching removal algorithm based on neighborhood searching and LBP histograms is adopted to improve the accuracy of feature matching. Finally, we rigorously evaluated the proposed approach using two different databases and obtained 0.996% and 3.112% Equal Error Rates (EERs), respectively, which demonstrate the effectiveness of the proposed approach.

  14. Finger Vein Recognition Based on Personalized Weight Maps

    Science.gov (United States)

    Yang, Gongping; Xiao, Rongyang; Yin, Yilong; Yang, Lu

    2013-01-01

    Finger vein recognition is a promising biometric recognition technology, which verifies identities via the vein patterns in the fingers. Binary pattern based methods were thoroughly studied in order to cope with the difficulties of extracting the blood vessel network. However, current binary pattern based finger vein matching methods treat every bit of feature codes derived from different image of various individuals as equally important and assign the same weight value to them. In this paper, we propose a finger vein recognition method based on personalized weight maps (PWMs). The different bits have different weight values according to their stabilities in a certain number of training samples from an individual. Firstly we present the concept of PWM, and then propose the finger vein recognition framework, which mainly consists of preprocessing, feature extraction, and matching. Finally, we design extensive experiments to evaluate the effectiveness of our proposal. Experimental results show that PWM achieves not only better performance, but also high robustness and reliability. In addition, PWM can be used as a general framework for binary pattern based recognition. PMID:24025556

  15. Finger Vein Recognition Based on Personalized Weight Maps

    Directory of Open Access Journals (Sweden)

    Lu Yang

    2013-09-01

    Full Text Available Finger vein recognition is a promising biometric recognition technology, which verifies identities via the vein patterns in the fingers. Binary pattern based methods were thoroughly studied in order to cope with the difficulties of extracting the blood vessel network. However, current binary pattern based finger vein matching methods treat every bit of feature codes derived from different image of various individuals as equally important and assign the same weight value to them. In this paper, we propose a finger vein recognition method based on personalized weight maps (PWMs. The different bits have different weight values according to their stabilities in a certain number of training samples from an individual. Firstly we present the concept of PWM, and then propose the finger vein recognition framework, which mainly consists of preprocessing, feature extraction, and matching. Finally, we design extensive experiments to evaluate the effectiveness of our proposal. Experimental results show that PWM achieves not only better performance, but also high robustness and reliability. In addition, PWM can be used as a general framework for binary pattern based recognition.

  16. Finger Vein Recognition Based on a Personalized Best Bit Map

    Science.gov (United States)

    Yang, Gongping; Xi, Xiaoming; Yin, Yilong

    2012-01-01

    Finger vein patterns have recently been recognized as an effective biometric identifier. In this paper, we propose a finger vein recognition method based on a personalized best bit map (PBBM). Our method is rooted in a local binary pattern based method and then inclined to use the best bits only for matching. We first present the concept of PBBM and the generating algorithm. Then we propose the finger vein recognition framework, which consists of preprocessing, feature extraction, and matching. Finally, we design extensive experiments to evaluate the effectiveness of our proposal. Experimental results show that PBBM achieves not only better performance, but also high robustness and reliability. In addition, PBBM can be used as a general framework for binary pattern based recognition. PMID:22438735

  17. Finger vein recognition based on convolutional neural network

    Directory of Open Access Journals (Sweden)

    Meng Gesi

    2017-01-01

    Full Text Available Biometric Authentication Technology has been widely used in this information age. As one of the most important technology of authentication, finger vein recognition attracts our attention because of its high security, reliable accuracy and excellent performance. However, the current finger vein recognition system is difficult to be applied widely because its complicated image pre-processing and not representative feature vectors. To solve this problem, a finger vein recognition method based on the convolution neural network (CNN is proposed in the paper. The image samples are directly input into the CNN model to extract its feature vector so that we can make authentication by comparing the Euclidean distance between these vectors. Finally, the Deep Learning Framework Caffe is adopted to verify this method. The result shows that there are great improvements in both speed and accuracy rate compared to the previous research. And the model has nice robustness in illumination and rotation.

  18. Palm vein recognition based on directional empirical mode decomposition

    Science.gov (United States)

    Lee, Jen-Chun; Chang, Chien-Ping; Chen, Wei-Kuei

    2014-04-01

    Directional empirical mode decomposition (DEMD) has recently been proposed to make empirical mode decomposition suitable for the processing of texture analysis. Using DEMD, samples are decomposed into a series of images, referred to as two-dimensional intrinsic mode functions (2-D IMFs), from finer to large scale. A DEMD-based 2 linear discriminant analysis (LDA) for palm vein recognition is proposed. The proposed method progresses through three steps: (i) a set of 2-D IMF features of various scale and orientation are extracted using DEMD, (ii) the 2LDA method is then applied to reduce the dimensionality of the feature space in both the row and column directions, and (iii) the nearest neighbor classifier is used for classification. We also propose two strategies for using the set of 2-D IMF features: ensemble DEMD vein representation (EDVR) and multichannel DEMD vein representation (MDVR). In experiments using palm vein databases, the proposed MDVR-based 2LDA method achieved recognition accuracy of 99.73%, thereby demonstrating its feasibility for palm vein recognition.

  19. Hand Gesture Recognition with Leap Motion

    OpenAIRE

    Du, Youchen; Liu, Shenglan; Feng, Lin; Chen, Menghui; Wu, Jie

    2017-01-01

    The recent introduction of depth cameras like Leap Motion Controller allows researchers to exploit the depth information to recognize hand gesture more robustly. This paper proposes a novel hand gesture recognition system with Leap Motion Controller. A series of features are extracted from Leap Motion tracking data, we feed these features along with HOG feature extracted from sensor images into a multi-class SVM classifier to recognize performed gesture, dimension reduction and feature weight...

  20. Finger Vein Recognition Using Local Line Binary Pattern

    Directory of Open Access Journals (Sweden)

    Bakhtiar Affendi Rosdi

    2011-11-01

    Full Text Available In this paper, a personal verification method using finger vein is presented. Finger vein can be considered more secured compared to other hands based biometric traits such as fingerprint and palm print because the features are inside the human body. In the proposed method, a new texture descriptor called local line binary pattern (LLBP is utilized as feature extraction technique. The neighbourhood shape in LLBP is a straight line, unlike in local binary pattern (LBP which is a square shape. Experimental results show that the proposed method using LLBP has better performance than the previous methods using LBP and local derivative pattern (LDP.

  1. Finger vein recognition using local line binary pattern.

    Science.gov (United States)

    Rosdi, Bakhtiar Affendi; Shing, Chai Wuh; Suandi, Shahrel Azmin

    2011-01-01

    In this paper, a personal verification method using finger vein is presented. Finger vein can be considered more secured compared to other hands based biometric traits such as fingerprint and palm print because the features are inside the human body. In the proposed method, a new texture descriptor called local line binary pattern (LLBP) is utilized as feature extraction technique. The neighbourhood shape in LLBP is a straight line, unlike in local binary pattern (LBP) which is a square shape. Experimental results show that the proposed method using LLBP has better performance than the previous methods using LBP and local derivative pattern (LDP).

  2. Finger Vein Recognition Using Local Line Binary Pattern

    Science.gov (United States)

    Rosdi, Bakhtiar Affendi; Shing, Chai Wuh; Suandi, Shahrel Azmin

    2011-01-01

    In this paper, a personal verification method using finger vein is presented. Finger vein can be considered more secured compared to other hands based biometric traits such as fingerprint and palm print because the features are inside the human body. In the proposed method, a new texture descriptor called local line binary pattern (LLBP) is utilized as feature extraction technique. The neighbourhood shape in LLBP is a straight line, unlike in local binary pattern (LBP) which is a square shape. Experimental results show that the proposed method using LLBP has better performance than the previous methods using LBP and local derivative pattern (LDP). PMID:22247670

  3. Hand Gesture Recognition Using Ultrasonic Waves

    KAUST Repository

    AlSharif, Mohammed Hussain

    2016-04-01

    Gesturing is a natural way of communication between people and is used in our everyday conversations. Hand gesture recognition systems are used in many applications in a wide variety of fields, such as mobile phone applications, smart TVs, video gaming, etc. With the advances in human-computer interaction technology, gesture recognition is becoming an active research area. There are two types of devices to detect gestures; contact based devices and contactless devices. Using ultrasonic waves for determining gestures is one of the ways that is employed in contactless devices. Hand gesture recognition utilizing ultrasonic waves will be the focus of this thesis work. This thesis presents a new method for detecting and classifying a predefined set of hand gestures using a single ultrasonic transmitter and a single ultrasonic receiver. This method uses a linear frequency modulated ultrasonic signal. The ultrasonic signal is designed to meet the project requirements such as the update rate, the range of detection, etc. Also, it needs to overcome hardware limitations such as the limited output power, transmitter, and receiver bandwidth, etc. The method can be adapted to other hardware setups. Gestures are identified based on two main features; range estimation of the moving hand and received signal strength (RSS). These two factors are estimated using two simple methods; channel impulse response (CIR) and cross correlation (CC) of the reflected ultrasonic signal from the gesturing hand. A customized simple hardware setup was used to classify a set of hand gestures with high accuracy. The detection and classification were done using methods of low computational cost. This makes the proposed method to have a great potential for the implementation in many devices including laptops and mobile phones. The predefined set of gestures can be used for many control applications.

  4. Research and implementation of finger-vein recognition algorithm

    Science.gov (United States)

    Pang, Zengyao; Yang, Jie; Chen, Yilei; Liu, Yin

    2017-06-01

    In finger vein image preprocessing, finger angle correction and ROI extraction are important parts of the system. In this paper, we propose an angle correction algorithm based on the centroid of the vein image, and extract the ROI region according to the bidirectional gray projection method. Inspired by the fact that features in those vein areas have similar appearance as valleys, a novel method was proposed to extract center and width of palm vein based on multi-directional gradients, which is easy-computing, quick and stable. On this basis, an encoding method was designed to determine the gray value distribution of texture image. This algorithm could effectively overcome the edge of the texture extraction error. Finally, the system was equipped with higher robustness and recognition accuracy by utilizing fuzzy threshold determination and global gray value matching algorithm. Experimental results on pairs of matched palm images show that, the proposed method has a EER with 3.21% extracts features at the speed of 27ms per image. It can be concluded that the proposed algorithm has obvious advantages in grain extraction efficiency, matching accuracy and algorithm efficiency.

  5. Towards NIRS-based hand movement recognition.

    Science.gov (United States)

    Paleari, Marco; Luciani, Riccardo; Ariano, Paolo

    2017-07-01

    This work reports on preliminary results about on hand movement recognition with Near InfraRed Spectroscopy (NIRS) and surface ElectroMyoGraphy (sEMG). Either basing on physical contact (touchscreens, data-gloves, etc.), vision techniques (Microsoft Kinect, Sony PlayStation Move, etc.), or other modalities, hand movement recognition is a pervasive function in today environment and it is at the base of many gaming, social, and medical applications. Albeit, in recent years, the use of muscle information extracted by sEMG has spread out from the medical applications to contaminate the consumer world, this technique still falls short when dealing with movements of the hand. We tested NIRS as a technique to get another point of view on the muscle phenomena and proved that, within a specific movements selection, NIRS can be used to recognize movements and return information regarding muscles at different depths. Furthermore, we propose here three different multimodal movement recognition approaches and compare their performances.

  6. Hand veins feature extraction using DT-CNNS

    Science.gov (United States)

    Malki, Suleyman; Spaanenburg, Lambert

    2007-05-01

    As the identification process is based on the unique patterns of the users, biometrics technologies are expected to provide highly secure authentication systems. The existing systems using fingerprints or retina patterns are, however, very vulnerable. One's fingerprints are accessible as soon as the person touches a surface, while a high resolution camera easily captures the retina pattern. Thus, both patterns can easily be "stolen" and forged. Beside, technical considerations decrease the usability for these methods. Due to the direct contact with the finger, the sensor gets dirty, which decreases the authentication success ratio. Aligning the eye with a camera to capture the retina pattern gives uncomfortable feeling. On the other hand, vein patterns of either a palm of the hand or a single finger offer stable, unique and repeatable biometrics features. A fingerprint-based identification system using Cellular Neural Networks has already been proposed by Gao. His system covers all stages of a typical fingerprint verification procedure from Image Preprocessing to Feature Matching. This paper performs a critical review of the individual algorithmic steps. Notably, the operation of False Feature Elimination is applied only once instead of 3 times. Furthermore, the number of iterations is limited to 1 for all used templates. Hence, the computational need of the feedback contribution is removed. Consequently the computational effort is drastically reduced without a notable chance in quality. This allows a full integration of the detection mechanism. The system is prototyped on a Xilinx Virtex II Pro P30 FPGA.

  7. Finger vein recognition based on the hyperinformation feature

    Science.gov (United States)

    Xi, Xiaoming; Yang, Gongping; Yin, Yilong; Yang, Lu

    2014-01-01

    The finger vein is a promising biometric pattern for personal identification due to its advantages over other existing biometrics. In finger vein recognition, feature extraction is a critical step, and many feature extraction methods have been proposed to extract the gray, texture, or shape of the finger vein. We treat them as low-level features and present a high-level feature extraction framework. Under this framework, base attribute is first defined to represent the characteristics of a certain subcategory of a subject. Then, for an image, the correlation coefficient is used for constructing the high-level feature, which reflects the correlation between this image and all base attributes. Since the high-level feature can reveal characteristics of more subcategories and contain more discriminative information, we call it hyperinformation feature (HIF). Compared with low-level features, which only represent the characteristics of one subcategory, HIF is more powerful and robust. In order to demonstrate the potential of the proposed framework, we provide a case study to extract HIF. We conduct comprehensive experiments to show the generality of the proposed framework and the efficiency of HIF on our databases, respectively. Experimental results show that HIF significantly outperforms the low-level features.

  8. Near-infrared image formation and processing for the extraction of hand veins

    Science.gov (United States)

    Bouzida, Nabila; Hakim Bendada, Abdel; Maldague, Xavier P.

    2010-10-01

    The main objective of this work is to extract the hand vein network using a non-invasive technique in the near-infrared region (NIR). The visualization of the veins is based on a relevant feature of the blood in relation with certain wavelengths of the electromagnetic spectrum. In the present paper, we first introduce the image formation in the NIR spectral band. Then, the acquisition system will be presented as well as the method used for the image processing in order to extract the vein signature. Extractions of this pattern on the finger, on the wrist and on the dorsal hand are achieved after exposing the hand to an optical stimulation by reflection or transmission of light. We present meaningful results of the extracted vein pattern demonstrating the utility of the method for a clinical application like the diagnosis of vein disease, of primitive varicose vein and also for applications in vein biometrics.

  9. Convolutional Neural Network-Based Finger-Vein Recognition Using NIR Image Sensors.

    Science.gov (United States)

    Hong, Hyung Gil; Lee, Min Beom; Park, Kang Ryoung

    2017-06-06

    Conventional finger-vein recognition systems perform recognition based on the finger-vein lines extracted from the input images or image enhancement, and texture feature extraction from the finger-vein images. In these cases, however, the inaccurate detection of finger-vein lines lowers the recognition accuracy. In the case of texture feature extraction, the developer must experimentally decide on a form of the optimal filter for extraction considering the characteristics of the image database. To address this problem, this research proposes a finger-vein recognition method that is robust to various database types and environmental changes based on the convolutional neural network (CNN). In the experiments using the two finger-vein databases constructed in this research and the SDUMLA-HMT finger-vein database, which is an open database, the method proposed in this research showed a better performance compared to the conventional methods.

  10. Intensity Variation Normalization for Finger Vein Recognition Using Guided Filter Based Singe Scale Retinex.

    Science.gov (United States)

    Xie, Shan Juan; Lu, Yu; Yoon, Sook; Yang, Jucheng; Park, Dong Sun

    2015-07-14

    Finger vein recognition has been considered one of the most promising biometrics for personal authentication. However, the capacities and percentages of finger tissues (e.g., bone, muscle, ligament, water, fat, etc.) vary person by person. This usually causes poor quality of finger vein images, therefore degrading the performance of finger vein recognition systems (FVRSs). In this paper, the intrinsic factors of finger tissue causing poor quality of finger vein images are analyzed, and an intensity variation (IV) normalization method using guided filter based single scale retinex (GFSSR) is proposed for finger vein image enhancement. The experimental results on two public datasets demonstrate the effectiveness of the proposed method in enhancing the image quality and finger vein recognition accuracy.

  11. Intensity Variation Normalization for Finger Vein Recognition Using Guided Filter Based Singe Scale Retinex

    Directory of Open Access Journals (Sweden)

    Shan Juan Xie

    2015-07-01

    Full Text Available Finger vein recognition has been considered one of the most promising biometrics for personal authentication. However, the capacities and percentages of finger tissues (e.g., bone, muscle, ligament, water, fat, etc. vary person by person. This usually causes poor quality of finger vein images, therefore degrading the performance of finger vein recognition systems (FVRSs. In this paper, the intrinsic factors of finger tissue causing poor quality of finger vein images are analyzed, and an intensity variation (IV normalization method using guided filter based single scale retinex (GFSSR is proposed for finger vein image enhancement. The experimental results on two public datasets demonstrate the effectiveness of the proposed method in enhancing the image quality and finger vein recognition accuracy.

  12. Hand gesture recognition by analysis of codons

    Science.gov (United States)

    Ramachandra, Poornima; Shrikhande, Neelima

    2007-09-01

    The problem of recognizing gestures from images using computers can be approached by closely understanding how the human brain tackles it. A full fledged gesture recognition system will substitute mouse and keyboards completely. Humans can recognize most gestures by looking at the characteristic external shape or the silhouette of the fingers. Many previous techniques to recognize gestures dealt with motion and geometric features of hands. In this thesis gestures are recognized by the Codon-list pattern extracted from the object contour. All edges of an image are described in terms of sequence of Codons. The Codons are defined in terms of the relationship between maxima, minima and zeros of curvature encountered as one traverses the boundary of the object. We have concentrated on a catalog of 24 gesture images from the American Sign Language alphabet (Letter J and Z are ignored as they are represented using motion) [2]. The query image given as an input to the system is analyzed and tested against the Codon-lists, which are shape descriptors for external parts of a hand gesture. We have used the Weighted Frequency Indexing Transform (WFIT) approach which is used in DNA sequence matching for matching the Codon-lists. The matching algorithm consists of two steps: 1) the query sequences are converted to short sequences and are assigned weights and, 2) all the sequences of query gestures are pruned into match and mismatch subsequences by the frequency indexing tree based on the weights of the subsequences. The Codon sequences with the most weight are used to determine the most precise match. Once a match is found, the identified gesture and corresponding interpretation are shown as output.

  13. Hand Gesture Recognition Using Ultrasonic Waves

    KAUST Repository

    AlSharif, Mohammed Hussain

    2016-01-01

    estimation of the moving hand and received signal strength (RSS). These two factors are estimated using two simple methods; channel impulse response (CIR) and cross correlation (CC) of the reflected ultrasonic signal from the gesturing hand. A customized

  14. Finger tips detection for two handed gesture recognition

    Science.gov (United States)

    Bhuyan, M. K.; Kar, Mithun Kumar; Neog, Debanga Raj

    2011-10-01

    In this paper, a novel algorithm is proposed for fingertips detection in view of two-handed static hand pose recognition. In our method, finger tips of both hands are detected after detecting hand regions by skin color-based segmentation. At first, the face is removed in the image by using Haar classifier and subsequently, the regions corresponding to the gesturing hands are isolated by a region labeling technique. Next, the key geometric features characterizing gesturing hands are extracted for two hands. Finally, for all possible/allowable finger movements, a probabilistic model is developed for pose recognition. Proposed method can be employed in a variety of applications like sign language recognition and human-robot-interactions etc.

  15. Hand-Geometry Recognition Based on Contour Parameters

    NARCIS (Netherlands)

    Veldhuis, Raymond N.J.; Bazen, A.M.; Booij, W.D.T.; Hendrikse, A.J.; Jain, A.K.; Ratha, N.K.

    This paper demonstrates the feasibility of a new method of hand-geometry recognition based on parameters derived from the contour of the hand. The contour is completely determined by the black-and-white image of the hand and can be derived from it by means of simple image-processing techniques. It

  16. Nonintrusive Finger-Vein Recognition System Using NIR Image Sensor and Accuracy Analyses According to Various Factors

    Directory of Open Access Journals (Sweden)

    Tuyen Danh Pham

    2015-07-01

    Full Text Available Biometrics is a technology that enables an individual person to be identified based on human physiological and behavioral characteristics. Among biometrics technologies, face recognition has been widely used because of its advantages in terms of convenience and non-contact operation. However, its performance is affected by factors such as variation in the illumination, facial expression, and head pose. Therefore, fingerprint and iris recognitions are preferred alternatives. However, the performance of the former can be adversely affected by the skin condition, including scarring and dryness. In addition, the latter has the disadvantages of high cost, large system size, and inconvenience to the user, who has to align their eyes with the iris camera. In an attempt to overcome these problems, finger-vein recognition has been vigorously researched, but an analysis of its accuracies according to various factors has not received much attention. Therefore, we propose a nonintrusive finger-vein recognition system using a near infrared (NIR image sensor and analyze its accuracies considering various factors. The experimental results obtained with three databases showed that our system can be operated in real applications with high accuracy; and the dissimilarity of the finger-veins of different people is larger than that of the finger types and hands.

  17. Nonintrusive Finger-Vein Recognition System Using NIR Image Sensor and Accuracy Analyses According to Various Factors.

    Science.gov (United States)

    Pham, Tuyen Danh; Park, Young Ho; Nguyen, Dat Tien; Kwon, Seung Yong; Park, Kang Ryoung

    2015-07-13

    Biometrics is a technology that enables an individual person to be identified based on human physiological and behavioral characteristics. Among biometrics technologies, face recognition has been widely used because of its advantages in terms of convenience and non-contact operation. However, its performance is affected by factors such as variation in the illumination, facial expression, and head pose. Therefore, fingerprint and iris recognitions are preferred alternatives. However, the performance of the former can be adversely affected by the skin condition, including scarring and dryness. In addition, the latter has the disadvantages of high cost, large system size, and inconvenience to the user, who has to align their eyes with the iris camera. In an attempt to overcome these problems, finger-vein recognition has been vigorously researched, but an analysis of its accuracies according to various factors has not received much attention. Therefore, we propose a nonintrusive finger-vein recognition system using a near infrared (NIR) image sensor and analyze its accuracies considering various factors. The experimental results obtained with three databases showed that our system can be operated in real applications with high accuracy; and the dissimilarity of the finger-veins of different people is larger than that of the finger types and hands.

  18. Parametric Primitives for Hand Gesture Recognition

    DEFF Research Database (Denmark)

    Baby, Sanmohan; Krüger, Volker

    2009-01-01

    Imitation learning is considered to be an effective way of teaching humanoid robots and action recognition is the key step to imitation learning. In this paper  an online algorithm to recognize parametric actions with object context is presented. Objects are key instruments in understanding...

  19. Real-Time Hand Posture Recognition Using a Range Camera

    Science.gov (United States)

    Lahamy, Herve

    The basic goal of human computer interaction is to improve the interaction between users and computers by making computers more usable and receptive to the user's needs. Within this context, the use of hand postures in replacement of traditional devices such as keyboards, mice and joysticks is being explored by many researchers. The goal is to interpret human postures via mathematical algorithms. Hand posture recognition has gained popularity in recent years, and could become the future tool for humans to interact with computers or virtual environments. An exhaustive description of the frequently used methods available in literature for hand posture recognition is provided. It focuses on the different types of sensors and data used, the segmentation and tracking methods, the features used to represent the hand postures as well as the classifiers considered in the recognition process. Those methods are usually presented as highly robust with a recognition rate close to 100%. However, a couple of critical points necessary for a successful real-time hand posture recognition system require major improvement. Those points include the features used to represent the hand segment, the number of postures simultaneously recognizable, the invariance of the features with respect to rotation, translation and scale and also the behavior of the classifiers against non-perfect hand segments for example segments including part of the arm or missing part of the palm. A 3D time-of-flight camera named SR4000 has been chosen to develop a new methodology because of its capability to provide in real-time and at high frame rate 3D information on the scene imaged. This sensor has been described and evaluated for its capability for capturing in real-time a moving hand. A new recognition method that uses the 3D information provided by the range camera to recognize hand postures has been proposed. The different steps of this methodology including the segmentation, the tracking, the hand

  20. LOCAL LINE BINARY PATTERN FOR FEATURE EXTRACTION ON PALM VEIN RECOGNITION

    Directory of Open Access Journals (Sweden)

    Jayanti Yusmah Sari

    2015-08-01

    Full Text Available In recent years, palm vein recognition has been studied to overcome problems in conventional systems in biometrics technology (finger print, face, and iris. Those problems in biometrics includes convenience and performance. However, due to the clarity of the palm vein image, the veins could not be segmented properly. To overcome this problem, we propose a palm vein recognition system using Local Line Binary Pattern (LLBP method that can extract robust features from the palm vein images that has unclear veins. LLBP is an advanced method of Local Binary Pattern (LBP, a texture descriptor based on the gray level comparison of a neighborhood of pixels. There are four major steps in this paper, Region of Interest (ROI detection, image preprocessing, features extraction using LLBP method, and matching using Fuzzy k-NN classifier. The proposed method was applied on the CASIA Multi-Spectral Image Database. Experimental results showed that the proposed method using LLBP has a good performance with recognition accuracy of 97.3%. In the future, experiments will be conducted to observe which parameter that could affect processing time and recognition accuracy of LLBP is needed

  1. An Efficient Solution for Hand Gesture Recognition from Video Sequence

    Directory of Open Access Journals (Sweden)

    PRODAN, R.-C.

    2012-08-01

    Full Text Available The paper describes a system of hand gesture recognition by image processing for human robot interaction. The recognition and interpretation of the hand postures acquired through a video camera allow the control of the robotic arm activity: motion - translation and rotation in 3D - and tightening/releasing the clamp. A gesture dictionary was defined and heuristic algorithms for recognition were developed and tested. The system can be used for academic and industrial purposes, especially for those activities where the movements of the robotic arm were not previously scheduled, for training the robot easier than using a remote control. Besides the gesture dictionary, the novelty of the paper consists in a new technique for detecting the relative positions of the fingers in order to recognize the various hand postures, and in the achievement of a robust system for controlling robots by postures of the hands.

  2. Finger-vein and fingerprint recognition based on a feature-level fusion method

    Science.gov (United States)

    Yang, Jinfeng; Hong, Bofeng

    2013-07-01

    Multimodal biometrics based on the finger identification is a hot topic in recent years. In this paper, a novel fingerprint-vein based biometric method is proposed to improve the reliability and accuracy of the finger recognition system. First, the second order steerable filters are used here to enhance and extract the minutiae features of the fingerprint (FP) and finger-vein (FV). Second, the texture features of fingerprint and finger-vein are extracted by a bank of Gabor filter. Third, a new triangle-region fusion method is proposed to integrate all the fingerprint and finger-vein features in feature-level. Thus, the fusion features contain both the finger texture-information and the minutiae triangular geometry structure. Finally, experimental results performed on the self-constructed finger-vein and fingerprint databases are shown that the proposed method is reliable and precise in personal identification.

  3. Electromyographic Grasp Recognition for a Five Fingered Robotic Hand

    Directory of Open Access Journals (Sweden)

    Nayan M. Kakoty

    2012-09-01

    Full Text Available This paper presents classification of grasp types based on surface electromyographic signals. Classification is through radial basis function kernel support vector machine using sum of wavelet decomposition coefficients of the EMG signals. In a study involving six subjects, we achieved an average recognition rate of 86%. The electromyographic grasp recognition together with a 8-bit microcontroller has been employed to control a fivefingered robotic hand to emulate six grasp types used during 70% daily living activities.

  4. Hand Biometric Recognition Based on Fused Hand Geometry and Vascular Patterns

    Science.gov (United States)

    Park, GiTae; Kim, Soowon

    2013-01-01

    A hand biometric authentication method based on measurements of the user's hand geometry and vascular pattern is proposed. To acquire the hand geometry, the thickness of the side view of the hand, the K-curvature with a hand-shaped chain code, the lengths and angles of the finger valleys, and the lengths and profiles of the fingers were used, and for the vascular pattern, the direction-based vascular-pattern extraction method was used, and thus, a new multimodal biometric approach is proposed. The proposed multimodal biometric system uses only one image to extract the feature points. This system can be configured for low-cost devices. Our multimodal biometric-approach hand-geometry (the side view of the hand and the back of hand) and vascular-pattern recognition method performs at the score level. The results of our study showed that the equal error rate of the proposed system was 0.06%. PMID:23449119

  5. Hand biometric recognition based on fused hand geometry and vascular patterns.

    Science.gov (United States)

    Park, GiTae; Kim, Soowon

    2013-02-28

    A hand biometric authentication method based on measurements of the user's hand geometry and vascular pattern is proposed. To acquire the hand geometry, the thickness of the side view of the hand, the K-curvature with a hand-shaped chain code, the lengths and angles of the finger valleys, and the lengths and profiles of the fingers were used, and for the vascular pattern, the direction-based vascular-pattern extraction method was used, and thus, a new multimodal biometric approach is proposed. The proposed multimodal biometric system uses only one image to extract the feature points. This system can be configured for low-cost devices. Our multimodal biometric-approach hand-geometry (the side view of the hand and the back of hand) and vascular-pattern recognition method performs at the score level. The results of our study showed that the equal error rate of the proposed system was 0.06%.

  6. Hand Vein Images Enhancement Based on Local Gray-level Information Histogram

    Directory of Open Access Journals (Sweden)

    Jun Wang

    2015-06-01

    Full Text Available Based on the Histogram equalization theory, this paper presents a novel concept of histogram to realize the contrast enhancement of hand vein images, avoiding the lost of topological vein structure or importing the fake vein information. Firstly, we propose the concept of gray-level information histogram, the fundamental characteristic of which is that the amplitudes of the components can objectively reflect the contribution of the gray levels and information to the representation of image information. Then, we propose the histogram equalization method that is composed of an automatic histogram separation module and an intensity transformation module, and the histogram separation module is a combination of the proposed prompt multiple threshold procedure and an optimum peak signal-to-noise (PSNR calculation to separate the histogram into small-scale detail, the use of the intensity transformation module can enhance the vein images with vein topological structure and gray information preservation for each generated sub-histogram. Experimental results show that the proposed method can achieve extremely good contrast enhancement effect.

  7. Finger Vein Recognition Using Optimal Partitioning Uniform Rotation Invariant LBP Descriptor

    Directory of Open Access Journals (Sweden)

    Bang Chao Liu

    2016-01-01

    Full Text Available As a promising biometric system, finger vein identification has been studied widely and many relevant researches have been proposed. However, it is hard to extract a satisfied finger vein pattern due to the various vein thickness, illumination, low contrast region, and noise existing. And most of the feature extraction algorithms rely on high-quality finger vein database and take a long time for a large dimensional feature vector. In this paper, we proposed two block selection methods which are based on the estimate of the amount of information in each block and the contribution of block location by looking at recognition rate of each block position to reduce feature extraction time and matching time. The specific approach is to find out some local finger vein areas with low-quality and noise, which will be useless for feature description. Local binary pattern (LBP descriptors are proposed to extract the finger vein pattern feature. Two finger vein databases are taken to test our algorithm performance. Experimental results show that proposed block selection algorithms can reduce the feature vector dimensionality in a large extent.

  8. Hand Gesture Recognition Using Modified 1$ and Background Subtraction Algorithms

    Directory of Open Access Journals (Sweden)

    Hazem Khaled

    2015-01-01

    Full Text Available Computers and computerized machines have tremendously penetrated all aspects of our lives. This raises the importance of Human-Computer Interface (HCI. The common HCI techniques still rely on simple devices such as keyboard, mice, and joysticks, which are not enough to convoy the latest technology. Hand gesture has become one of the most important attractive alternatives to existing traditional HCI techniques. This paper proposes a new hand gesture detection system for Human-Computer Interaction using real-time video streaming. This is achieved by removing the background using average background algorithm and the 1$ algorithm for hand’s template matching. Then every hand gesture is translated to commands that can be used to control robot movements. The simulation results show that the proposed algorithm can achieve high detection rate and small recognition time under different light changes, scales, rotation, and background.

  9. A natural approach to convey numerical digits using hand activity recognition based on hand shape features

    Science.gov (United States)

    Chidananda, H.; Reddy, T. Hanumantha

    2017-06-01

    This paper presents a natural representation of numerical digit(s) using hand activity analysis based on number of fingers out stretched for each numerical digit in sequence extracted from a video. The analysis is based on determining a set of six features from a hand image. The most important features used from each frame in a video are the first fingertip from top, palm-line, palm-center, valley points between the fingers exists above the palm-line. Using this work user can convey any number of numerical digits using right or left or both the hands naturally in a video. Each numerical digit ranges from 0 to9. Hands (right/left/both) used to convey digits can be recognized accurately using the valley points and with this recognition whether the user is a right / left handed person in practice can be analyzed. In this work, first the hand(s) and face parts are detected by using YCbCr color space and face part is removed by using ellipse based method. Then, the hand(s) are analyzed to recognize the activity that represents a series of numerical digits in a video. This work uses pixel continuity algorithm using 2D coordinate geometry system and does not use regular use of calculus, contours, convex hull and datasets.

  10. Accurate palm vein recognition based on wavelet scattering and spectral regression kernel discriminant analysis

    Science.gov (United States)

    Elnasir, Selma; Shamsuddin, Siti Mariyam; Farokhi, Sajad

    2015-01-01

    Palm vein recognition (PVR) is a promising new biometric that has been applied successfully as a method of access control by many organizations, which has even further potential in the field of forensics. The palm vein pattern has highly discriminative features that are difficult to forge because of its subcutaneous position in the palm. Despite considerable progress and a few practical issues, providing accurate palm vein readings has remained an unsolved issue in biometrics. We propose a robust and more accurate PVR method based on the combination of wavelet scattering (WS) with spectral regression kernel discriminant analysis (SRKDA). As the dimension of WS generated features is quite large, SRKDA is required to reduce the extracted features to enhance the discrimination. The results based on two public databases-PolyU Hyper Spectral Palmprint public database and PolyU Multi Spectral Palmprint-show the high performance of the proposed scheme in comparison with state-of-the-art methods. The proposed approach scored a 99.44% identification rate and a 99.90% verification rate [equal error rate (EER)=0.1%] for the hyperspectral database and a 99.97% identification rate and a 99.98% verification rate (EER=0.019%) for the multispectral database.

  11. Computational intelligence in multi-feature visual pattern recognition hand posture and face recognition using biologically inspired approaches

    CERN Document Server

    Pisharady, Pramod Kumar; Poh, Loh Ai

    2014-01-01

    This book presents a collection of computational intelligence algorithms that addresses issues in visual pattern recognition such as high computational complexity, abundance of pattern features, sensitivity to size and shape variations and poor performance against complex backgrounds. The book has 3 parts. Part 1 describes various research issues in the field with a survey of the related literature. Part 2 presents computational intelligence based algorithms for feature selection and classification. The algorithms are discriminative and fast. The main application area considered is hand posture recognition. The book also discusses utility of these algorithms in other visual as well as non-visual pattern recognition tasks including face recognition, general object recognition and cancer / tumor classification. Part 3 presents biologically inspired algorithms for feature extraction. The visual cortex model based features discussed have invariance with respect to appearance and size of the hand, and provide good...

  12. "Like the palm of my hands": Motor imagery enhances implicit and explicit visual recognition of one's own hands.

    Science.gov (United States)

    Conson, Massimiliano; Volpicella, Francesco; De Bellis, Francesco; Orefice, Agnese; Trojano, Luigi

    2017-10-01

    A key point in motor imagery literature is that judging hands in palm view recruits sensory-motor information to a higher extent than judging hands in back view, due to the greater biomechanical complexity implied in rotating hands depicted from palm than from back. We took advantage from this solid evidence to test the nature of a phenomenon known as self-advantage, i.e. the advantage in implicitly recognizing self vs. others' hand images. The self-advantage has been actually found when implicitly but not explicitly judging self-hands, likely due to dissociation between implicit and explicit body representations. However, such a finding might be related to the extent to which motor imagery is recruited during implicit and explicit processing of hand images. We tested this hypothesis in two behavioural experiments. In Experiment 1, right-handed participants judged laterality of either self or others' hands, whereas in Experiment 2, an explicit recognition of one's own hands was required. Crucially, in both experiments participants were randomly presented with hand images viewed from back or from palm. The main result of both experiments was the self-advantage when participants judged hands from palm view. This novel finding demonstrate that increasing the "motor imagery load" during processing of self vs. others' hands can elicit a self-advantage in explicit recognition tasks as well. Future studies testing the possible dissociation between implicit and explicit visual body representations should take into account the modulatory effect of motor imagery load on self-hand processing. Copyright © 2017. Published by Elsevier B.V.

  13. NUI framework based on real-time head pose estimation and hand gesture recognition

    Directory of Open Access Journals (Sweden)

    Kim Hyunduk

    2016-01-01

    Full Text Available The natural user interface (NUI is used for the natural motion interface without using device or tool such as mice, keyboards, pens and markers. In this paper, we develop natural user interface framework based on two recognition module. First module is real-time head pose estimation module using random forests and second module is hand gesture recognition module, named Hand gesture Key Emulation Toolkit (HandGKET. Using the head pose estimation module, we can know where the user is looking and what the user’s focus of attention is. Moreover, using the hand gesture recognition module, we can also control the computer using the user’s hand gesture without mouse and keyboard. In proposed framework, the user’s head direction and hand gesture are mapped into mouse and keyboard event, respectively.

  14. An Approach for Pattern Recognition of EEG Applied in Prosthetic Hand Drive

    Directory of Open Access Journals (Sweden)

    Xiao-Dong Zhang

    2011-12-01

    Full Text Available For controlling the prosthetic hand by only electroencephalogram (EEG, it has become the hot spot in robotics research to set up a direct communication and control channel between human brain and prosthetic hand. In this paper, the EEG signal is analyzed based on multi-complicated hand activities. And then, two methods of EEG pattern recognition are investigated, a neural prosthesis hand system driven by BCI is set up, which can complete four kinds of actions (arm’s free state, arm movement, hand crawl, hand open. Through several times of off-line and on-line experiments, the result shows that the neural prosthesis hand system driven by BCI is reasonable and feasible, the C-support vector classifiers-based method is better than BP neural network on the EEG pattern recognition for multi-complicated hand activities.

  15. Gender-related Changes in Dorsal Hand and Foot Vein Function Following 60 Days of Head Down Bed Rest

    Science.gov (United States)

    Westby, Christian M.; Phillips, Tiffany; Stenger, Michael B.; Platts, Steven H.

    2009-01-01

    It is well known that female astronauts are more likely to experience post-flight orthostatic hypotension and presyncope compared to male astronauts. It has been suggested that the disproportionally higher incidence of presyncope (83% of female vs. 20% male crewmembers) may be due to sex-related differences in vascular function between the upper and lower limbs. However, much of this evidence is specific to changes in resistance vessels. Given that more than 70% of the circulating blood volume resides in compliance vessels, it is conceivable that even small changes in venous function may contribute to post-flight orthostatic hypotension. In spite of this, little is currently known regarding the influence of microgravity exposure on venous function between males and females. PURPOSE: To determine the influence of 60 days of HDBR on dorsal foot and hand vein function between healthy males (M) and females (F). METHODS: Using 2-D ultrasound, dorsal hand and foot vein diameter responses to intravenous infusions phenylephrine (PE), acetylcholine (ACh), and nitroglycerine (NTG) were determined in 26 adults; 10 females (age:37 +/- 2 yr ) and 16 males (age:34 +/- 2 yr ). Changes in venous function were calculated as the difference between diameter at baseline and following each venoactive drug. Differences in venous function between limb and sexes across HDBR were determined using mixed-effects linear regression. RESULTS: In response to 60 days of HDBR, the change in venousconstrictor response to PE in the dorsal hand veins was not significantly different between M and F. Interestingly, the change in constrictor response in the dorsal foot veins (compared to pre HDBR) was approximately 30% greater in the F, whereas the constrictor response was approximately 45% less in the M (p=0.026). HDBR had no influence on the change in dilator response to ACh, or NTG between M and F and between vascular beds. CONCLUSION: These results demonstrate that 60 days of HDBR contributes to sex

  16. Hand based visual intent recognition algorithm for wheelchair motion

    CSIR Research Space (South Africa)

    Luhandjula, T

    2010-05-01

    Full Text Available This paper describes an algorithm for a visual human-machine interface that infers a person’s intention from the motion of the hand. Work in progress shows a proof of concept tested on static images. The context for which this solution is intended...

  17. An Analysis of Intrinsic and Extrinsic Hand Muscle EMG for Improved Pattern Recognition Control.

    Science.gov (United States)

    Adewuyi, Adenike A; Hargrove, Levi J; Kuiken, Todd A

    2016-04-01

    Pattern recognition control combined with surface electromyography (EMG) from the extrinsic hand muscles has shown great promise for control of multiple prosthetic functions for transradial amputees. There is, however, a need to adapt this control method when implemented for partial-hand amputees, who possess both a functional wrist and information-rich residual intrinsic hand muscles. We demonstrate that combining EMG data from both intrinsic and extrinsic hand muscles to classify hand grasps and finger motions allows up to 19 classes of hand grasps and individual finger motions to be decoded, with an accuracy of 96% for non-amputees and 85% for partial-hand amputees. We evaluated real-time pattern recognition control of three hand motions in seven different wrist positions. We found that a system trained with both intrinsic and extrinsic muscle EMG data, collected while statically and dynamically varying wrist position increased completion rates from 73% to 96% for partial-hand amputees and from 88% to 100% for non-amputees when compared to a system trained with only extrinsic muscle EMG data collected in a neutral wrist position. Our study shows that incorporating intrinsic muscle EMG data and wrist motion can significantly improve the robustness of pattern recognition control for application to partial-hand prosthetic control.

  18. Body schema and corporeal self-recognition in the alien hand syndrome.

    Science.gov (United States)

    Olgiati, Elena; Maravita, Angelo; Spandri, Viviana; Casati, Roberta; Ferraro, Francesco; Tedesco, Lucia; Agostoni, Elio Clemente; Bolognini, Nadia

    2017-07-01

    The alien hand syndrome (AHS) is a rare neuropsychological disorder characterized by involuntary, yet purposeful, hand movements. Patients with the AHS typically complain about a loss of agency associated with a feeling of estrangement for actions performed by the affected limb. The present study explores the integrity of the body representation in AHS, focusing on 2 main processes: multisensory integration and visual self-recognition of body parts. Three patients affected by AHS following a right-hemisphere stroke, with clinical symptoms akin to the posterior variant of AHS, were tested and their performance was compared with that of 18 age-matched healthy controls. AHS patients and controls underwent 2 experimental tasks: a same-different visual matching task for body postures, which assessed the ability of using your own body schema for encoding others' body postural changes (Experiment 1), and an explicit self-hand recognition task, which assessed the ability to visually recognize your own hands (Experiment 2). As compared to controls, all AHS patients were unable to access a reliable multisensory representation of their alien hand and use it for decoding others' postural changes; however, they could rely on an efficient multisensory representation of their intact (ipsilesional) hand. Two AHS patients also presented with a specific impairment in the visual self-recognition of their alien hand, but normal recognition of their intact hand. This evidence suggests that the AHS following a right-hemisphere stroke may involve a disruption of the multisensory representation of the alien limb; instead, self-hand recognition mechanisms may be spared. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  19. Combining heterogenous features for 3D hand-held object recognition

    Science.gov (United States)

    Lv, Xiong; Wang, Shuang; Li, Xiangyang; Jiang, Shuqiang

    2014-10-01

    Object recognition has wide applications in the area of human-machine interaction and multimedia retrieval. However, due to the problem of visual polysemous and concept polymorphism, it is still a great challenge to obtain reliable recognition result for the 2D images. Recently, with the emergence and easy availability of RGB-D equipment such as Kinect, this challenge could be relieved because the depth channel could bring more information. A very special and important case of object recognition is hand-held object recognition, as hand is a straight and natural way for both human-human interaction and human-machine interaction. In this paper, we study the problem of 3D object recognition by combining heterogenous features with different modalities and extraction techniques. For hand-craft feature, although it reserves the low-level information such as shape and color, it has shown weakness in representing hiconvolutionalgh-level semantic information compared with the automatic learned feature, especially deep feature. Deep feature has shown its great advantages in large scale dataset recognition but is not always robust to rotation or scale variance compared with hand-craft feature. In this paper, we propose a method to combine hand-craft point cloud features and deep learned features in RGB and depth channle. First, hand-held object segmentation is implemented by using depth cues and human skeleton information. Second, we combine the extracted hetegerogenous 3D features in different stages using linear concatenation and multiple kernel learning (MKL). Then a training model is used to recognize 3D handheld objects. Experimental results validate the effectiveness and gerneralization ability of the proposed method.

  20. Localization and Recognition of Dynamic Hand Gestures Based on Hierarchy of Manifold Classifiers

    Science.gov (United States)

    Favorskaya, M.; Nosov, A.; Popov, A.

    2015-05-01

    Generally, the dynamic hand gestures are captured in continuous video sequences, and a gesture recognition system ought to extract the robust features automatically. This task involves the highly challenging spatio-temporal variations of dynamic hand gestures. The proposed method is based on two-level manifold classifiers including the trajectory classifiers in any time instants and the posture classifiers of sub-gestures in selected time instants. The trajectory classifiers contain skin detector, normalized skeleton representation of one or two hands, and motion history representing by motion vectors normalized through predetermined directions (8 and 16 in our case). Each dynamic gesture is separated into a set of sub-gestures in order to predict a trajectory and remove those samples of gestures, which do not satisfy to current trajectory. The posture classifiers involve the normalized skeleton representation of palm and fingers and relative finger positions using fingertips. The min-max criterion is used for trajectory recognition, and the decision tree technique was applied for posture recognition of sub-gestures. For experiments, a dataset "Multi-modal Gesture Recognition Challenge 2013: Dataset and Results" including 393 dynamic hand-gestures was chosen. The proposed method yielded 84-91% recognition accuracy, in average, for restricted set of dynamic gestures.

  1. LOCALIZATION AND RECOGNITION OF DYNAMIC HAND GESTURES BASED ON HIERARCHY OF MANIFOLD CLASSIFIERS

    Directory of Open Access Journals (Sweden)

    M. Favorskaya

    2015-05-01

    Full Text Available Generally, the dynamic hand gestures are captured in continuous video sequences, and a gesture recognition system ought to extract the robust features automatically. This task involves the highly challenging spatio-temporal variations of dynamic hand gestures. The proposed method is based on two-level manifold classifiers including the trajectory classifiers in any time instants and the posture classifiers of sub-gestures in selected time instants. The trajectory classifiers contain skin detector, normalized skeleton representation of one or two hands, and motion history representing by motion vectors normalized through predetermined directions (8 and 16 in our case. Each dynamic gesture is separated into a set of sub-gestures in order to predict a trajectory and remove those samples of gestures, which do not satisfy to current trajectory. The posture classifiers involve the normalized skeleton representation of palm and fingers and relative finger positions using fingertips. The min-max criterion is used for trajectory recognition, and the decision tree technique was applied for posture recognition of sub-gestures. For experiments, a dataset “Multi-modal Gesture Recognition Challenge 2013: Dataset and Results” including 393 dynamic hand-gestures was chosen. The proposed method yielded 84–91% recognition accuracy, in average, for restricted set of dynamic gestures.

  2. A Real-time Face/Hand Tracking Method for Chinese Sign Language Recognition

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    This paper introduces a new Chinese Sign Language recognition (CSLR) system and a method of real-time tracking face and hand applied in the system. In the method, an improved agent algorithm is used to extract the region of face and hand and track them. Kalman filter is introduced to forecast the position and rectangle of search, and self-adapting of target color is designed to counteract the effect of illumination.

  3. LOCALIZATION AND RECOGNITION OF DYNAMIC HAND GESTURES BASED ON HIERARCHY OF MANIFOLD CLASSIFIERS

    OpenAIRE

    M. Favorskaya; A. Nosov; A. Popov

    2015-01-01

    Generally, the dynamic hand gestures are captured in continuous video sequences, and a gesture recognition system ought to extract the robust features automatically. This task involves the highly challenging spatio-temporal variations of dynamic hand gestures. The proposed method is based on two-level manifold classifiers including the trajectory classifiers in any time instants and the posture classifiers of sub-gestures in selected time instants. The trajectory classifiers contain skin dete...

  4. Optimizing pattern recognition-based control for partial-hand prosthesis application.

    Science.gov (United States)

    Earley, Eric J; Adewuyi, Adenike A; Hargrove, Levi J

    2014-01-01

    Partial-hand amputees often retain good residual wrist motion, which is essential for functional activities involving use of the hand. Thus, a crucial design criterion for a myoelectric, partial-hand prosthesis control scheme is that it allows the user to retain residual wrist motion. Pattern recognition (PR) of electromyographic (EMG) signals is a well-studied method of controlling myoelectric prostheses. However, wrist motion degrades a PR system's ability to correctly predict hand-grasp patterns. We studied the effects of (1) window length and number of hand-grasps, (2) static and dynamic wrist motion, and (3) EMG muscle source on the ability of a PR-based control scheme to classify functional hand-grasp patterns. Our results show that training PR classifiers with both extrinsic and intrinsic muscle EMG yields a lower error rate than training with either group by itself (pgrasps available to the classifier significantly decrease classification error (pgrasp.

  5. Effects of Isometric Hand-Grip Muscle Contraction on Young Adults' Free Recall and Recognition Memory

    Science.gov (United States)

    Tomporowski, Phillip D.; Albrecht, Chelesa; Pendleton, Daniel M.

    2017-01-01

    Purpose: The purpose of this study was to determine if physical arousal produced by isometric hand-dynamometer contraction performed during word-list learning affects young adults' free recall or recognition memory. Method: Twenty-four young adults (12 female; M[subscript age] = 22 years) were presented with 4 20-item word lists. Moderate arousal…

  6. Real-Time Control of an Exoskeleton Hand Robot with Myoelectric Pattern Recognition.

    Science.gov (United States)

    Lu, Zhiyuan; Chen, Xiang; Zhang, Xu; Tong, Kay-Yu; Zhou, Ping

    2017-08-01

    Robot-assisted training provides an effective approach to neurological injury rehabilitation. To meet the challenge of hand rehabilitation after neurological injuries, this study presents an advanced myoelectric pattern recognition scheme for real-time intention-driven control of a hand exoskeleton. The developed scheme detects and recognizes user's intention of six different hand motions using four channels of surface electromyography (EMG) signals acquired from the forearm and hand muscles, and then drives the exoskeleton to assist the user accomplish the intended motion. The system was tested with eight neurologically intact subjects and two individuals with spinal cord injury (SCI). The overall control accuracy was [Formula: see text] for the neurologically intact subjects and [Formula: see text] for the SCI subjects. The total lag of the system was approximately 250[Formula: see text]ms including data acquisition, transmission and processing. One SCI subject also participated in training sessions in his second and third visits. Both the control accuracy and efficiency tended to improve. These results show great potential for applying the advanced myoelectric pattern recognition control of the wearable robotic hand system toward improving hand function after neurological injuries.

  7. Using virtual data for training deep model for hand gesture recognition

    Science.gov (United States)

    Nikolaev, E. I.; Dvoryaninov, P. V.; Lensky, Y. Y.; Drozdovsky, N. S.

    2018-05-01

    Deep learning has shown real promise for the classification efficiency for hand gesture recognition problems. In this paper, the authors present experimental results for a deeply-trained model for hand gesture recognition through the use of hand images. The authors have trained two deep convolutional neural networks. The first architecture produces the hand position as a 2D-vector by input hand image. The second one predicts the hand gesture class for the input image. The first proposed architecture produces state of the art results with an accuracy rate of 89% and the second architecture with split input produces accuracy rate of 85.2%. In this paper, the authors also propose using virtual data for training a supervised deep model. Such technique is aimed to avoid using original labelled images in the training process. The interest of this method in data preparation is motivated by the need to overcome one of the main challenges of deep supervised learning: using a copious amount of labelled data during training.

  8. Hand gesture recognition in confined spaces with partial observability and occultation constraints

    Science.gov (United States)

    Shirkhodaie, Amir; Chan, Alex; Hu, Shuowen

    2016-05-01

    Human activity detection and recognition capabilities have broad applications for military and homeland security. These tasks are very complicated, however, especially when multiple persons are performing concurrent activities in confined spaces that impose significant obstruction, occultation, and observability uncertainty. In this paper, our primary contribution is to present a dedicated taxonomy and kinematic ontology that are developed for in-vehicle group human activities (IVGA). Secondly, we describe a set of hand-observable patterns that represents certain IVGA examples. Thirdly, we propose two classifiers for hand gesture recognition and compare their performance individually and jointly. Finally, we present a variant of Hidden Markov Model for Bayesian tracking, recognition, and annotation of hand motions, which enables spatiotemporal inference to human group activity perception and understanding. To validate our approach, synthetic (graphical data from virtual environment) and real physical environment video imagery are employed to verify the performance of these hand gesture classifiers, while measuring their efficiency and effectiveness based on the proposed Hidden Markov Model for tracking and interpreting dynamic spatiotemporal IVGA scenarios.

  9. Hand posture effects on handedness recognition as revealed by the Simon effect

    Directory of Open Access Journals (Sweden)

    Allan P Lameira

    2009-11-01

    Full Text Available We investigated the influence of hand posture in handedness recognition, while varying the spatial correspondence between stimulus and response in a modified Simon task. Drawings of the left and right hands were displayed either in a back or palm view while participants discriminated stimulus handedness by pressing left/right keys with their hands resting either in a prone or supine posture. As a control, subjects performed a regular Simon task using simple geometric shapes as stimuli. Results showed that when hands were in a prone posture, the spatially corresponding trials (i.e., stimulus and response located on the same side were faster than the non-corresponding trials (i.e., stimulus and response on opposite sides. In contrast, for the supine posture, there was no difference between corresponding and non-corresponding trials. The control experiment with the regular Simon task showed that the posture of the responding hand had no influence on performance. When the stimulus is the drawing of a hand, however, the posture of the responding hand affects the spatial correspondence effect because response location is coded based on multiple reference points, including the body of the hand.

  10. An observational study of implicit motor imagery using laterality recognition of the hand after stroke.

    Science.gov (United States)

    Amesz, Sarah; Tessari, Alessia; Ottoboni, Giovanni; Marsden, Jon

    2016-01-01

    To explore the relationship between laterality recognition after stroke and impairments in attention, 3D object rotation and functional ability. Observational cross-sectional study. Acute care teaching hospital. Thirty-two acute and sub-acute people with stroke and 36 healthy, age-matched controls. Laterality recognition, attention and mental rotation of objects. Within the stroke group, the relationship between laterality recognition and functional ability, neglect, hemianopia and dyspraxia were further explored. People with stroke were significantly less accurate (69% vs 80%) and showed delayed reaction times (3.0 vs 1.9 seconds) when determining the laterality of a pictured hand. Deficits either in accuracy or reaction times were seen in 53% of people with stroke. The accuracy of laterality recognition was associated with reduced functional ability (R(2) = 0.21), less accurate mental rotation of objects (R(2) = 0.20) and dyspraxia (p = 0.03). Implicit motor imagery is affected in a significant number of patients after stroke with these deficits related to lesions to the motor networks as well as other deficits seen after stroke. This research provides new insights into how laterality recognition is related to a number of other deficits after stroke, including the mental rotation of 3D objects, attention and dyspraxia. Further research is required to determine if treatment programmes can improve deficits in laterality recognition and impact functional outcomes after stroke.

  11. Shape-based hand recognition approach using the morphological pattern spectrum

    Science.gov (United States)

    Ramirez-Cortes, Juan Manuel; Gomez-Gil, Pilar; Sanchez-Perez, Gabriel; Prieto-Castro, Cesar

    2009-01-01

    We propose the use of the morphological pattern spectrum, or pecstrum, as the base of a biometric shape-based hand recognition system. The system receives an image of the right hand of a subject in an unconstrained pose, which is captured with a commercial flatbed scanner. According to pecstrum property of invariance to translation and rotation, the system does not require the use of pegs for a fixed hand position, which simplifies the image acquisition process. This novel feature-extraction method is tested using a Euclidean distance classifier for identification and verification cases, obtaining 97% correct identification, and an equal error rate (EER) of 0.0285 (2.85%) for the verification mode. The obtained results indicate that the pattern spectrum represents a good feature-extraction alternative for low- and medium-level hand-shape-based biometric applications.

  12. RGBD Video Based Human Hand Trajectory Tracking and Gesture Recognition System

    Directory of Open Access Journals (Sweden)

    Weihua Liu

    2015-01-01

    Full Text Available The task of human hand trajectory tracking and gesture trajectory recognition based on synchronized color and depth video is considered. Toward this end, in the facet of hand tracking, a joint observation model with the hand cues of skin saliency, motion and depth is integrated into particle filter in order to move particles to local peak in the likelihood. The proposed hand tracking method, namely, salient skin, motion, and depth based particle filter (SSMD-PF, is capable of improving the tracking accuracy considerably, in the context of the signer performing the gesture toward the camera device and in front of moving, cluttered backgrounds. In the facet of gesture recognition, a shape-order context descriptor on the basis of shape context is introduced, which can describe the gesture in spatiotemporal domain. The efficient shape-order context descriptor can reveal the shape relationship and embed gesture sequence order information into descriptor. Moreover, the shape-order context leads to a robust score for gesture invariant. Our approach is complemented with experimental results on the settings of the challenging hand-signed digits datasets and American sign language dataset, which corroborate the performance of the novel techniques.

  13. A Prosthetic Hand Body Area Controller Based on Efficient Pattern Recognition Control Strategies.

    Science.gov (United States)

    Benatti, Simone; Milosevic, Bojan; Farella, Elisabetta; Gruppioni, Emanuele; Benini, Luca

    2017-04-15

    Poliarticulated prosthetic hands represent a powerful tool to restore functionality and improve quality of life for upper limb amputees. Such devices offer, on the same wearable node, sensing and actuation capabilities, which are not equally supported by natural interaction and control strategies. The control in state-of-the-art solutions is still performed mainly through complex encoding of gestures in bursts of contractions of the residual forearm muscles, resulting in a non-intuitive Human-Machine Interface (HMI). Recent research efforts explore the use of myoelectric gesture recognition for innovative interaction solutions, however there persists a considerable gap between research evaluation and implementation into successful complete systems. In this paper, we present the design of a wearable prosthetic hand controller, based on intuitive gesture recognition and a custom control strategy. The wearable node directly actuates a poliarticulated hand and wirelessly interacts with a personal gateway (i.e., a smartphone) for the training and personalization of the recognition algorithm. Through the whole system development, we address the challenge of integrating an efficient embedded gesture classifier with a control strategy tailored for an intuitive interaction between the user and the prosthesis. We demonstrate that this combined approach outperforms systems based on mere pattern recognition, since they target the accuracy of a classification algorithm rather than the control of a gesture. The system was fully implemented, tested on healthy and amputee subjects and compared against benchmark repositories. The proposed approach achieves an error rate of 1.6% in the end-to-end real time control of commonly used hand gestures, while complying with the power and performance budget of a low-cost microcontroller.

  14. Viewpoint Integration for Hand-Based Recognition of Social Interactions from a First-Person View.

    Science.gov (United States)

    Bambach, Sven; Crandall, David J; Yu, Chen

    2015-11-01

    Wearable devices are becoming part of everyday life, from first-person cameras (GoPro, Google Glass), to smart watches (Apple Watch), to activity trackers (FitBit). These devices are often equipped with advanced sensors that gather data about the wearer and the environment. These sensors enable new ways of recognizing and analyzing the wearer's everyday personal activities, which could be used for intelligent human-computer interfaces and other applications. We explore one possible application by investigating how egocentric video data collected from head-mounted cameras can be used to recognize social activities between two interacting partners (e.g. playing chess or cards). In particular, we demonstrate that just the positions and poses of hands within the first-person view are highly informative for activity recognition, and present a computer vision approach that detects hands to automatically estimate activities. While hand pose detection is imperfect, we show that combining evidence across first-person views from the two social partners significantly improves activity recognition accuracy. This result highlights how integrating weak but complimentary sources of evidence from social partners engaged in the same task can help to recognize the nature of their interaction.

  15. Portal vein branching order helps in the recognition of anomalous right-sided round ligament: common features and variations in portal vein anatomy.

    Science.gov (United States)

    Yamashita, Rikiya; Yamaoka, Toshihide; Nishitai, Ryuta; Isoda, Hiroyoshi; Taura, Kojiro; Arizono, Shigeki; Furuta, Akihiro; Ohno, Tsuyoshi; Ono, Ayako; Togashi, Kaori

    2017-07-01

    This study aimed to evaluate the common features and variations of portal vein anatomy in right-sided round ligament (RSRL), which can help propose a method to detect and diagnose this anomaly. In this retrospective study of 14 patients with RSRL, the branching order of the portal tree was analyzed, with special focus on the relationship between the dorsal branch of the right anterior segmental portal vein (P A-D ) and the lateral segmental portal vein (P LL ), to determine the common features. The configuration of the portal vein from the main portal trunk to the right umbilical portion (RUP), the inclination of the RUP, and the number and thickness of the ramifications branching from the right anterior segmental portal vein (P A ) were evaluated for variations. In all subjects, the diverging point of the P A-D was constantly distal to that of the P LL . The portal vein configuration was I- and Z-shaped in nine and five subjects, respectively. The RUP was tilted to the right in all subjects. In Z-shaped subjects, the portal trunk between the branching point of the right posterior segmental portal vein and that of the P LL was tilted to the left in one subject and was almost parallel to the vertical plane in four subjects. Multiple ramifications were radially distributed from the P A in eight subjects, whereas one predominant P A-D branched from the P A in six subjects. Based on the diverging points of the P A-D and P LL , we proposed a three-step method for the detection and diagnosis of RSRL.

  16. Impact of body posture on laterality judgement and explicit recognition tasks performed on self and others' hands.

    Science.gov (United States)

    Conson, Massimiliano; Errico, Domenico; Mazzarella, Elisabetta; De Bellis, Francesco; Grossi, Dario; Trojano, Luigi

    2015-04-01

    Judgments on laterality of hand stimuli are faster and more accurate when dealing with one's own than others' hand, i.e. the self-advantage. This advantage seems to be related to activation of a sensorimotor mechanism while implicitly processing one's own hands, but not during explicit one's own hand recognition. Here, we specifically tested the influence of proprioceptive information on the self-hand advantage by manipulating participants' body posture during self and others' hand processing. In Experiment 1, right-handed healthy participants judged laterality of either self or others' hands, whereas in Experiment 2, an explicit recognition of one's own hands was required. In both experiments, the participants performed the task while holding their left or right arm flexed with their hand in direct contact with their chest ("flexed self-touch posture") or with their hand placed on a wooden smooth surface in correspondence with their chest ("flexed proprioceptive-only posture"). In an "extended control posture", both arms were extended and in contact with thighs. In Experiment 1 (hand laterality judgment), we confirmed the self-advantage and demonstrated that it was enhanced when the subjects judged left-hand stimuli at 270° orientation while keeping their left arm in the flexed proprioceptive-only posture. In Experiment 2 (explicit self-hand recognition), instead, we found an advantage for others' hand ("self-disadvantage") independently from posture manipulation. Thus, position-related proprioceptive information from left non-dominant arm can enhance sensorimotor one's own body representation selectively favouring implicit self-hands processing.

  17. Handling movement epenthesis and hand segmentation ambiguities in continuous sign language recognition using nested dynamic programming.

    Science.gov (United States)

    Yang, Ruiduo; Sarkar, Sudeep; Loeding, Barbara

    2010-03-01

    We consider two crucial problems in continuous sign language recognition from unaided video sequences. At the sentence level, we consider the movement epenthesis (me) problem and at the feature level, we consider the problem of hand segmentation and grouping. We construct a framework that can handle both of these problems based on an enhanced, nested version of the dynamic programming approach. To address movement epenthesis, a dynamic programming (DP) process employs a virtual me option that does not need explicit models. We call this the enhanced level building (eLB) algorithm. This formulation also allows the incorporation of grammar models. Nested within this eLB is another DP that handles the problem of selecting among multiple hand candidates. We demonstrate our ideas on four American Sign Language data sets with simple background, with the signer wearing short sleeves, with complex background, and across signers. We compared the performance with Conditional Random Fields (CRF) and Latent Dynamic-CRF-based approaches. The experiments show more than 40 percent improvement over CRF or LDCRF approaches in terms of the frame labeling rate. We show the flexibility of our approach when handling a changing context. We also find a 70 percent improvement in sign recognition rate over the unenhanced DP matching algorithm that does not accommodate the me effect.

  18. Interacting with mobile devices by fusion eye and hand gestures recognition systems based on decision tree approach

    Science.gov (United States)

    Elleuch, Hanene; Wali, Ali; Samet, Anis; Alimi, Adel M.

    2017-03-01

    Two systems of eyes and hand gestures recognition are used to control mobile devices. Based on a real-time video streaming captured from the device's camera, the first system recognizes the motion of user's eyes and the second one detects the static hand gestures. To avoid any confusion between natural and intentional movements we developed a system to fuse the decision coming from eyes and hands gesture recognition systems. The phase of fusion was based on decision tree approach. We conducted a study on 5 volunteers and the results that our system is robust and competitive.

  19. Hand Gesture Modeling and Recognition for Human and Robot Interactive Assembly Using Hidden Markov Models

    Directory of Open Access Journals (Sweden)

    Fei Chen

    2015-04-01

    Full Text Available Gesture recognition is essential for human and robot collaboration. Within an industrial hybrid assembly cell, the performance of such a system significantly affects the safety of human workers. This work presents an approach to recognizing hand gestures accurately during an assembly task while in collaboration with a robot co-worker. We have designed and developed a sensor system for measuring natural human-robot interactions. The position and rotation information of a human worker's hands and fingertips are tracked in 3D space while completing a task. A modified chain-code method is proposed to describe the motion trajectory of the measured hands and fingertips. The Hidden Markov Model (HMM method is adopted to recognize patterns via data streams and identify workers' gesture patterns and assembly intentions. The effectiveness of the proposed system is verified by experimental results. The outcome demonstrates that the proposed system is able to automatically segment the data streams and recognize the gesture patterns thus represented with a reasonable accuracy ratio.

  20. Deep Visual Attributes vs. Hand-Crafted Audio Features on Multidomain Speech Emotion Recognition

    Directory of Open Access Journals (Sweden)

    Michalis Papakostas

    2017-06-01

    Full Text Available Emotion recognition from speech may play a crucial role in many applications related to human–computer interaction or understanding the affective state of users in certain tasks, where other modalities such as video or physiological parameters are unavailable. In general, a human’s emotions may be recognized using several modalities such as analyzing facial expressions, speech, physiological parameters (e.g., electroencephalograms, electrocardiograms etc. However, measuring of these modalities may be difficult, obtrusive or require expensive hardware. In that context, speech may be the best alternative modality in many practical applications. In this work we present an approach that uses a Convolutional Neural Network (CNN functioning as a visual feature extractor and trained using raw speech information. In contrast to traditional machine learning approaches, CNNs are responsible for identifying the important features of the input thus, making the need of hand-crafted feature engineering optional in many tasks. In this paper no extra features are required other than the spectrogram representations and hand-crafted features were only extracted for validation purposes of our method. Moreover, it does not require any linguistic model and is not specific to any particular language. We compare the proposed approach using cross-language datasets and demonstrate that it is able to provide superior results vs. traditional ones that use hand-crafted features.

  1. Universal Robot Hand Equipped with Tactile and Joint Torque Sensors: Development and Experiments on Stiffness Control and Object Recognition

    Directory of Open Access Journals (Sweden)

    Hiroyuki NAKAMOTO

    2007-04-01

    Full Text Available Various humanoid robots have been developed and multifunction robot hands which are able to attach those robots like human hand is needed. But a useful robot hand has not been depeveloped, because there are a lot of problems such as control method of many degrees of freedom and processing method of enormous sensor outputs. Realizing such robot hand, we have developed five-finger robot hand. In this paper, the detailed structure of developed robot hand is described. The robot hand we developed has five fingers of multi-joint that is equipped with joint torque sensors and tactile sensors. We report experimental results of a stiffness control with the developed robot hand. Those results show that it is possible to change the stiffness of joints. Moreover we propose an object recognition method with the tactile sensor. The validity of that method is assured by experimental results.

  2. Kinect-based sign language recognition of static and dynamic hand movements

    Science.gov (United States)

    Dalawis, Rando C.; Olayao, Kenneth Deniel R.; Ramos, Evan Geoffrey I.; Samonte, Mary Jane C.

    2017-02-01

    A different approach of sign language recognition of static and dynamic hand movements was developed in this study using normalized correlation algorithm. The goal of this research was to translate fingerspelling sign language into text using MATLAB and Microsoft Kinect. Digital input image captured by Kinect devices are matched from template samples stored in a database. This Human Computer Interaction (HCI) prototype was developed to help people with communication disability to express their thoughts with ease. Frame segmentation and feature extraction was used to give meaning to the captured images. Sequential and random testing was used to test both static and dynamic fingerspelling gestures. The researchers explained some factors they encountered causing some misclassification of signs.

  3. Finger Angle-Based Hand Gesture Recognition for Smart Infrastructure Using Wearable Wrist-Worn Camera

    Directory of Open Access Journals (Sweden)

    Feiyu Chen

    2018-03-01

    Full Text Available The arising of domestic robots in smart infrastructure has raised demands for intuitive and natural interaction between humans and robots. To address this problem, a wearable wrist-worn camera (WwwCam is proposed in this paper. With the capability of recognizing human hand gestures in real-time, it enables services such as controlling mopping robots, mobile manipulators, or appliances in smart-home scenarios. The recognition is based on finger segmentation and template matching. Distance transformation algorithm is adopted and adapted to robustly segment fingers from the hand. Based on fingers’ angles relative to the wrist, a finger angle prediction algorithm and a template matching metric are proposed. All possible gesture types of the captured image are first predicted, and then evaluated and compared to the template image to achieve the classification. Unlike other template matching methods relying highly on large training set, this scheme possesses high flexibility since it requires only one image as the template, and can classify gestures formed by different combinations of fingers. In the experiment, it successfully recognized ten finger gestures from number zero to nine defined by American Sign Language with an accuracy up to 99.38%. Its performance was further demonstrated by manipulating a robot arm using the implemented algorithms and WwwCam to transport and pile up wooden building blocks.

  4. Sketch Style Recognition, Transfer and Synthesis of Hand-Drawn Sketches

    KAUST Repository

    Shaheen, Sara

    2017-07-19

    Humans have always used sketches to explain the visual world. It is a simple and straight- forward mean to communicate new ideas and designs. Consequently, as in almost every aspect of our modern life, the relatively recent major developments in computer science have highly contributed to enhancing individual sketching experience. The literature of sketch related research has witnessed seminal advancements and a large body of interest- ing work. Following up with this rich literature, this dissertation provides a holistic study on sketches through three proposed novel models including sketch analysis, transfer, and geometric representation. The first part of the dissertation targets sketch authorship recognition and analysis of sketches. It provides answers to the following questions: Are simple strokes unique to the artist or designer who renders them? If so, can this idea be used to identify authorship or to classify artistic drawings? The proposed stroke authorship recognition approach is a novel method that distinguishes the authorship of 2D digitized drawings. This method converts a drawing into a histogram of stroke attributes that is discriminative of authorship. Extensive classification experiments on a large variety of datasets are conducted to validate the ability of the proposed techniques to distinguish unique authorship of artists and designers. The second part of the dissertation is concerned with sketch style transfer from one free- hand drawing to another. The proposed method exploits techniques from multi-disciplinary areas including geometrical modeling and image processing. It consists of two methods of transfer: stroke-style and brush-style transfer. (1) Stroke-style transfer aims to transfer the style of the input sketch at the stroke level to the style encountered in other sketches by other artists. This is done by modifying all the parametric stroke segments in the input, so as to minimize a global stroke-level distance between the input and

  5. The usefulness of contrast material injection at the dorsal vein of the hand in 64-detecter row helical CT coronary angiography

    International Nuclear Information System (INIS)

    Kawano, Youji; Yakabe, Kazuaki; Urata, Jungo; Eto, Miyuki; Yamaguchi, Hiroichiro

    2011-01-01

    In 315 cases of multi detector row CT (MDCT) coronary angiography contrast material were injected at the dorsal vein of the hand. Early 168 cases were used 80 ml of 370 mgI/ml contrast material and later 147 cases were used 350-480 mgI/kg contrast material. In all cases contrast material was injected by 4 ml/sec with post injection of 30-40 ml physiologic saline. The attenuation of RCA No.3 and other coronary arteries or coronary artery bypass graft (CABG) graft was measured. In later cases the usefulness of above 300 HU was 95.2%. In all cases the usefulness was 92.6%. (author)

  6. Ultrasound-guided catheterization of the left subclavian vein without recognition of persistent left superior vena cava

    OpenAIRE

    Park, Sun Young; Yoo, Jae Hwa; Kim, Mun Gyu; Kim, Sang Ho; Park, Byoung-Won; Oh, Hong Chul; Kim, Hojoon

    2017-01-01

    Abstract Rationale: A persistent left superior vena cava (PLSVC) is rare, but the most common thoracic venous anomaly. We report a case of PLSVC unrecognized during left subclavian vein catheterization using real-time ultrasound-guided supraclavicular approach. Patient concerns: A 79-year-old man with history of hypertension presented with traumatic subdural hemorrhage, subarachnoid hemorrhage, and epidural hemorrhage. Before the operation, a central venous catheter (CVC) was placed into the ...

  7. Robotic Hand-Assisted Training for Spinal Cord Injury Driven by Myoelectric Pattern Recognition: A Case Report.

    Science.gov (United States)

    Lu, Zhiyuan; Tong, Kai-Yu; Shin, Henry; Stampas, Argyrios; Zhou, Ping

    2017-10-01

    A 51-year-old man with an incomplete C6 spinal cord injury sustained 26 yrs ago attended twenty 2-hr visits over 10 wks for robot-assisted hand training driven by myoelectric pattern recognition. In each visit, his right hand was assisted to perform motions by an exoskeleton robot, while the robot was triggered by his own motion intentions. The hand robot was designed for this study, which can perform six kinds of motions, including hand closing/opening; thumb, index finger, and middle finger closing/opening; and middle, ring, and little fingers closing/opening. After the training, his grip force increased from 13.5 to 19.6 kg, his pinch force remained the same (5.0 kg), his score of Box and Block test increased from 32 to 39, and his score from the Graded Redefined Assessment of Strength, Sensibility, and Prehension test Part 4.B increased from 22 to 24. He accomplished the tasks in the Graded Redefined Assessment of Strength, Sensibility, and Prehension test Part 4.B 28.8% faster on average. The results demonstrate the feasibility and effectiveness of robot-assisted training driven by myoelectric pattern recognition after spinal cord injury.

  8. Hand pose recognition in First Person Vision through graph spectral analysis

    NARCIS (Netherlands)

    Baydoun, Mohamad; Betancourt, Alejandro; Morerio, Pietro; Marcenaro, Lucio; Rauterberg, Matthias; Regazzoni, Carlo

    2017-01-01

    © 2017 IEEE. With the growing availability of wearable technology, video recording devices have become so intimately tied to individuals, that they are able to record the movements of users' hands, making hand-based applications one the most explored area in First Person Vision (FPV). In particular,

  9. Learning through hand- or typewriting influences visual recognition of new graphic shapes: behavioral and functional imaging evidence.

    Science.gov (United States)

    Longcamp, Marieke; Boucard, Céline; Gilhodes, Jean-Claude; Anton, Jean-Luc; Roth, Muriel; Nazarian, Bruno; Velay, Jean-Luc

    2008-05-01

    Fast and accurate visual recognition of single characters is crucial for efficient reading. We explored the possible contribution of writing memory to character recognition processes. We evaluated the ability of adults to discriminate new characters from their mirror images after being taught how to produce the characters either by traditional pen-and-paper writing or with a computer keyboard. After training, we found stronger and longer lasting (several weeks) facilitation in recognizing the orientation of characters that had been written by hand compared to those typed. Functional magnetic resonance imaging recordings indicated that the response mode during learning is associated with distinct pathways during recognition of graphic shapes. Greater activity related to handwriting learning and normal letter identification was observed in several brain regions known to be involved in the execution, imagery, and observation of actions, in particular, the left Broca's area and bilateral inferior parietal lobules. Taken together, these results provide strong arguments in favor of the view that the specific movements memorized when learning how to write participate in the visual recognition of graphic shapes and letters.

  10. When Passive Feels Active--Delusion-Proneness Alters Self-Recognition in the Moving Rubber Hand Illusion.

    Science.gov (United States)

    Louzolo, Anaïs; Kalckert, Andreas; Petrovic, Predrag

    2015-01-01

    Psychotic patients have problems with bodily self-recognition such as the experience of self-produced actions (sense of agency) and the perception of the body as their own (sense of ownership). While it has been shown that such impairments in psychotic patients can be explained by hypersalient processing of external sensory input it has also been suggested that they lack normal efference copy in voluntary action. However, it is not known how problems with motor predictions like efference copy contribute to impaired sense of agency and ownership in psychosis or psychosis-related states. We used a rubber hand illusion based on finger movements and measured sense of agency and ownership to compute a bodily self-recognition score in delusion-proneness (indexed by Peters' Delusion Inventory - PDI). A group of healthy subjects (n=71) experienced active movements (involving motor predictions) or passive movements (lacking motor predictions). We observed a highly significant correlation between delusion-proneness and self-recognition in the passive conditions, while no such effect was observed in the active conditions. This was seen for both ownership and agency scores. The result suggests that delusion-proneness is associated with hypersalient external input in passive conditions, resulting in an abnormal experience of the illusion. We hypothesize that this effect is not present in the active condition because deficient motor predictions counteract hypersalience in psychosis proneness.

  11. Repeatability of grasp recognition for robotic hand prosthesis control based on sEMG data.

    Science.gov (United States)

    Palermo, Francesca; Cognolato, Matteo; Gijsberts, Arjan; Muller, Henning; Caputo, Barbara; Atzori, Manfredo

    2017-07-01

    Control methods based on sEMG obtained promising results for hand prosthetics. Control system robustness is still often inadequate and does not allow the amputees to perform a large number of movements useful for everyday life. Only few studies analyzed the repeatability of sEMG classification of hand grasps. The main goals of this paper are to explore repeatability in sEMG data and to release a repeatability database with the recorded experiments. The data are recorded from 10 intact subjects repeating 7 grasps 12 times, twice a day for 5 days. The data are publicly available on the Ninapro web page. The analysis for the repeatability is based on the comparison of movement classification accuracy in several data acquisitions and for different subjects. The analysis is performed using mean absolute value and waveform length features and a Random Forest classifier. The accuracy obtained by training and testing on acquisitions at different times is on average 27.03% lower than training and testing on the same acquisition. The results obtained by training and testing on different acquisitions suggest that previous acquisitions can be used to train the classification algorithms. The inter-subject variability is remarkable, suggesting that specific characteristics of the subjects can affect repeatibility and sEMG classification accuracy. In conclusion, the results of this paper can contribute to develop more robust control systems for hand prostheses, while the presented data allows researchers to test repeatability in further analyses.

  12. Dexterous hand gestures recognition based on low-density sEMG signals for upper-limb forearm amputees

    Directory of Open Access Journals (Sweden)

    John Jairo Villarejo Mayor

    2017-08-01

    Full Text Available Abstract Introduction Intuitive prosthesis control is one of the most important challenges in order to reduce the user effort in learning how to use an artificial hand. This work presents the development of a novel method for pattern recognition of sEMG signals able to discriminate, in a very accurate way, dexterous hand and fingers movements using a reduced number of electrodes, which implies more confidence and usability for amputees. Methods The system was evaluated for ten forearm amputees and the results were compared with the performance of able-bodied subjects. Multiple sEMG features based on fractal analysis (detrended fluctuation analysis and Higuchi’s fractal dimension combined with traditional magnitude-based features were analyzed. Genetic algorithms and sequential forward selection were used to select the best set of features. Support vector machine (SVM, K-nearest neighbors (KNN and linear discriminant analysis (LDA were analyzed to classify individual finger flexion, hand gestures and different grasps using four electrodes, performing contractions in a natural way to accomplish these tasks. Statistical significance was computed for all the methods using different set of features, for both groups of subjects (able-bodied and amputees. Results The results showed average accuracy up to 99.2% for able-bodied subjects and 98.94% for amputees using SVM, followed very closely by KNN. However, KNN also produces a good performance, as it has a lower computational complexity, which implies an advantage for real-time applications. Conclusion The results show that the method proposed is promising for accurately controlling dexterous prosthetic hands, providing more functionality and better acceptance for amputees.

  13. A proposal of decontamination robot using 3D hand-eye-dual-cameras solid recognition and accuracy validation

    International Nuclear Information System (INIS)

    Minami, Mamoru; Nishimura, Kenta; Sunami, Yusuke; Yanou, Akira; Yu, Cui; Yamashita, Manabu; Ishiyama, Shintaro

    2015-01-01

    New robotic system that uses three dimensional measurement with solid object recognition —3D-MOS (Three Dimensional Move on Sensing)— based on visual servoing technology was designed and the on-board hand-eye-dual-cameras robot system has been developed to reduce risks of radiation exposure during decontamination processes by filter press machine that solidifies and reduces the volume of irradiation contaminated soil. The feature of 3D-MoS includes; (1) the both hand-eye-dual-cameras take the images of target object near the intersection of both lenses' centerlines, (2) the observation at intersection enables both cameras can see target object almost at the center of both images, (3) then it brings benefits as reducing the effect of lens aberration and improving the detection accuracy of three dimensional position. In this study, accuracy validation test of interdigitation of the robot's hand into filter cloth rod of the filter press —the task is crucial for the robot to remove the contaminated cloth from the filter press machine automatically and for preventing workers from exposing to radiation—, was performed. Then the following results were derived; (1) the 3D-MoS controlled robot could recognize the rod at arbitrary position within designated space, and all of insertion test were carried out successfully and, (2) test results also demonstrated that the proposed control guarantees that interdigitation clearance between the rod and robot hand can be kept within 1.875[mm] with standard deviation being 0.6[mm] or less. (author)

  14. A New Profile Shape Matching Stereovision Algorithm for Real-time Human Pose and Hand Gesture Recognition

    Directory of Open Access Journals (Sweden)

    Dong Zhang

    2014-02-01

    Full Text Available This paper presents a new profile shape matching stereovision algorithm that is designed to extract 3D information in real time. This algorithm obtains 3D information by matching profile intensity shapes of each corresponding row of the stereo image pair. It detects the corresponding matching patterns of the intensity profile rather than the intensity values of individual pixels or pixels in a small neighbourhood. This approach reduces the effect of the intensity and colour variations caused by lighting differences. As with all real-time vision algorithms, there is always a trade-off between accuracy and processing speed. This algorithm achieves a balance between the two to produce accurate results for real-time applications. To demonstrate its performance, the proposed algorithm is tested for human pose and hand gesture recognition to control a smart phone and an entertainment system.

  15. Performance Comparison of Several Pre-Processing Methods in a Hand Gesture Recognition System based on Nearest Neighbor for Different Background Conditions

    Directory of Open Access Journals (Sweden)

    Iwan Setyawan

    2012-12-01

    Full Text Available This paper presents a performance analysis and comparison of several pre-processing methods used in a hand gesture recognition system. The pre-processing methods are based on the combinations of several image processing operations, namely edge detection, low pass filtering, histogram equalization, thresholding and desaturation. The hand gesture recognition system is designed to classify an input image into one of six possible classes. The input images are taken with various background conditions. Our experiments showed that the best result is achieved when the pre-processing method consists of only a desaturation operation, achieving a classification accuracy of up to 83.15%.

  16. Recognition

    DEFF Research Database (Denmark)

    Gimmler, Antje

    2017-01-01

    In this article, I shall examine the cognitive, heuristic and theoretical functions of the concept of recognition. To evaluate both the explanatory power and the limitations of a sociological concept, the theory construction must be analysed and its actual productivity for sociological theory mus...

  17. Sclerotherapy of Varicose Veins and Spider Veins

    Science.gov (United States)

    ... Index A-Z Sclerotherapy of Varicose Veins and Spider Veins Sclerotherapy uses injections from a very fine, ... Sclerotherapy? What is Sclerotherapy of Varicose Veins and Spider Veins? Sclerotherapy is a minimally invasive treatment used ...

  18. Performance Comparison of Several Pre-Processing Methods in a Hand Gesture Recognition System based on Nearest Neighbor for Different Background Conditions

    Directory of Open Access Journals (Sweden)

    Regina Lionnie

    2013-09-01

    Full Text Available This paper presents a performance analysis and comparison of several pre-processing  methods  used  in  a  hand  gesture  recognition  system.  The  preprocessing methods are based on the combinations ofseveral image processing operations,  namely  edge  detection,  low  pass  filtering,  histogram  equalization, thresholding and desaturation. The hand gesture recognition system is designed to classify an input image into one of six possibleclasses. The input images are taken with various background conditions. Our experiments showed that the best result is achieved when the pre-processing method consists of only a desaturation operation, achieving a classification accuracy of up to 83.15%.

  19. Preduodenal portal vein: its surgical significance.

    Science.gov (United States)

    Makey, D A; Bowen, J C

    1978-11-01

    Preduodenal portal vein is a rare anatomical variant which may be one of many anomalies in the neonate with duodenal "atresia." Preduodenal portal vein also may be an occasional finding in an adult undergoing biliary, gastric, or pancreatic surgery. Awareness and recognition of the anomaly are essential for the avoidance of injury during such operations. We report here a symptomless patient whose preduodenal portal vein was discovered at cholecystectomy.

  20. A Vein Map Biometric System

    Directory of Open Access Journals (Sweden)

    Felix Fuentes

    2013-08-01

    Full Text Available There is increasing demand world-wide, from government agencies and the private sector for cutting-edge biometric security technology that is difficult to breach but userfriendly at the same time. Some of the older tools, such as fingerprint, retina and iris scanning, and facial recognition software have all been found to have flaws and often viewed negatively because of many cultural and hygienic issues associated with them. Comparatively, mapping veins as a human barcode, a new technology, has many advantages over older technologies. Specifically, reproducing a three-dimensional model of a human vein system is impossible to replicate. Vein map technology is distinctive because of its state-of-the-art sensors are only able to recognize vein patterns if hemoglobin is actively flowing through the person

  1. Portal vein thrombosis.

    Science.gov (United States)

    Chawla, Yogesh K; Bodh, Vijay

    2015-03-01

    Portal vein thrombosis is an important cause of portal hypertension. PVT occurs in association with cirrhosis or as a result of malignant invasion by hepatocellular carcinoma or even in the absence of associated liver disease. With the current research into its genesis, majority now have an underlying prothrombotic state detectable. Endothelial activation and stagnant portal blood flow also contribute to formation of the thrombus. Acute non-cirrhotic PVT, chronic PVT (EHPVO), and portal vein thrombosis in cirrhosis are the three main variants of portal vein thrombosis with varying etiological factors and variability in presentation and management. Procoagulant state should be actively investigated. Anticoagulation is the mainstay of therapy for acute non-cirrhotic PVT, with supporting evidence for its use in cirrhotic population as well. Chronic PVT (EHPVO) on the other hand requires the management of portal hypertension as such and with role for anticoagulation in the setting of underlying prothrombotic state, however data is awaited in those with no underlying prothrombotic states. TIPS and liver transplant may be feasible even in the setting of PVT however proper selection of candidates and type of surgery is warranted. Thrombolysis and thrombectomy have some role. TARE is a new modality for management of HCC with portal vein invasion.

  2. Varicose vein - noninvasive treatment

    Science.gov (United States)

    ... spider veins. These are small varicose veins. Salt water (saline) or a chemical solution is injected into the varicose vein. The vein will harden and then disappear. Laser treatment can be used on the surface of the skin. Small bursts ...

  3. Varicose vein stripping

    Science.gov (United States)

    ... stripping; Venous reflux - vein stripping; Venous ulcer - veins Patient Instructions Surgical wound care - open Varicose veins - what to ask your doctor Images Circulatory system References American Family Physician. Management of varicose veins. www.aafp.org/afp/2008/ ...

  4. What Are Varicose Veins?

    Science.gov (United States)

    ... Leer en español What Is Varicose (VAR-i-kos) veins are swollen, twisted veins that you can ... TA-ze-uhs), spider veins, varicoceles (VAR-i-ko-seals), and other vein problems. Telangiectasias Telangiectasias are ...

  5. Vein matching using artificial neural network in vein authentication systems

    Science.gov (United States)

    Noori Hoshyar, Azadeh; Sulaiman, Riza

    2011-10-01

    Personal identification technology as security systems is developing rapidly. Traditional authentication modes like key; password; card are not safe enough because they could be stolen or easily forgotten. Biometric as developed technology has been applied to a wide range of systems. According to different researchers, vein biometric is a good candidate among other biometric traits such as fingerprint, hand geometry, voice, DNA and etc for authentication systems. Vein authentication systems can be designed by different methodologies. All the methodologies consist of matching stage which is too important for final verification of the system. Neural Network is an effective methodology for matching and recognizing individuals in authentication systems. Therefore, this paper explains and implements the Neural Network methodology for finger vein authentication system. Neural Network is trained in Matlab to match the vein features of authentication system. The Network simulation shows the quality of matching as 95% which is a good performance for authentication system matching.

  6. Focus on Varicose Veins

    Science.gov (United States)

    ... because the valves of the veins no longer work. Under the pressure of gravity these veins can continue to expand and, in ... and to determine whether the vein valves are work- ing properly or have ... painless. How are varicose veins treated? Varicose veins are always ...

  7. Varicose Veins - Multiple Languages

    Science.gov (United States)

    ... Concerns and Discomforts of Pregnancy: Varicose Veins - English MP3 Concerns and Discomforts of Pregnancy: Varicose Veins - 简体中文 (Chinese, Simplified (Mandarin dialect)) MP3 Concerns and Discomforts of Pregnancy: Varicose Veins - English ...

  8. Spider Vein Removal

    Science.gov (United States)

    Spider veins: How are they removed? I have spider veins on my legs. What options are available ... M.D. Several options are available to remove spider veins — thin red lines or weblike networks of ...

  9. Haar-like Rectangular Features for Biometric Recognition

    DEFF Research Database (Denmark)

    Nasrollahi, Kamal; Moeslund, Thomas B.; Rashidi, Maryam

    2013-01-01

    Developing a reliable, fast, and robust biometric recognition system is still a challenging task. This is because the inputs to these systems can be noisy, occluded, poorly illuminated, rotated, and of very low-resolutions. This paper proposes a probabilistic classifier using Haar-like features......, which mostly have been used for detection, for biometric recognition. The proposed system has been tested for three different biometrics: ear, iris, and hand vein patterns and it is shown that it is robust against most of the mentioned degradations and it outperforms state-of-the-art systems...

  10. Portal Vein Thrombosis

    Directory of Open Access Journals (Sweden)

    Hakan Demirci

    2016-01-01

    Full Text Available Portal vein thrombosis is an important cause of presinusoidal portal hypertension. Portal vein thrombosis commonly occurs in patient with cirrhosis, malignancy and prothrombotic states. Patients with acute portal vein thrombosis have immediate onset. Patients with chronic portal vein thrombosis have developed portal hypertension and cavernous portal transformation. Portal vein thrombosis is diagnosed with doppler ultrasound, computed tomography and magnetic resonance imaging. Therapy with low molecular weight heparin achieves recanalization in more than half of acute cases.

  11. An Alternative Myoelectric Pattern Recognition Approach for the Control of Hand Prostheses: A Case Study of Use in Daily Life by a Dysmelia Subject

    Science.gov (United States)

    Ahlberg, Johan; Lendaro, Eva; Hermansson, Liselotte; Håkansson, Bo; Ortiz-Catalan, Max

    2018-01-01

    The functionality of upper limb prostheses can be improved by intuitive control strategies that use bioelectric signals measured at the stump level. One such strategy is the decoding of motor volition via myoelectric pattern recognition (MPR), which has shown promising results in controlled environments and more recently in clinical practice. Moreover, not much has been reported about daily life implementation and real-time accuracy of these decoding algorithms. This paper introduces an alternative approach in which MPR allows intuitive control of four different grips and open/close in a multifunctional prosthetic hand. We conducted a clinical proof-of-concept in activities of daily life by constructing a self-contained, MPR-controlled, transradial prosthetic system provided with a novel user interface meant to log errors during real-time operation. The system was used for five days by a unilateral dysmelia subject whose hand had never developed, and who nevertheless learned to generate patterns of myoelectric activity, reported as intuitive, for multi-functional prosthetic control. The subject was instructed to manually log errors when they occurred via the user interface mounted on the prosthesis. This allowed the collection of information about prosthesis usage and real-time classification accuracy. The assessment of capacity for myoelectric control test was used to compare the proposed approach to the conventional prosthetic control approach, direct control. Regarding the MPR approach, the subject reported a more intuitive control when selecting the different grips, but also a higher uncertainty during proportional continuous movements. This paper represents an alternative to the conventional use of MPR, and this alternative may be particularly suitable for a certain type of amputee patients. Moreover, it represents a further validation of MPR with dysmelia cases. PMID:29637030

  12. Augmented reality based real-time subcutaneous vein imaging system.

    Science.gov (United States)

    Ai, Danni; Yang, Jian; Fan, Jingfan; Zhao, Yitian; Song, Xianzheng; Shen, Jianbing; Shao, Ling; Wang, Yongtian

    2016-07-01

    A novel 3D reconstruction and fast imaging system for subcutaneous veins by augmented reality is presented. The study was performed to reduce the failure rate and time required in intravenous injection by providing augmented vein structures that back-project superimposed veins on the skin surface of the hand. Images of the subcutaneous vein are captured by two industrial cameras with extra reflective near-infrared lights. The veins are then segmented by a multiple-feature clustering method. Vein structures captured by the two cameras are matched and reconstructed based on the epipolar constraint and homographic property. The skin surface is reconstructed by active structured light with spatial encoding values and fusion displayed with the reconstructed vein. The vein and skin surface are both reconstructed in the 3D space. Results show that the structures can be precisely back-projected to the back of the hand for further augmented display and visualization. The overall system performance is evaluated in terms of vein segmentation, accuracy of vein matching, feature points distance error, duration times, accuracy of skin reconstruction, and augmented display. All experiments are validated with sets of real vein data. The imaging and augmented system produces good imaging and augmented reality results with high speed.

  13. Authentication using finger-vein recognition

    OpenAIRE

    2013-01-01

    M.Sc. (Information Technology) Biometrics is a unique method used to identify humans by distinct biological characterises. In recent years biometrics are showing up everywhere from homes, workplaces, schools and banks. This identification method is rapidly replacing existing methods such as passwords since it offers a higher level of security compared to existing methods. Fingerprints are the most common biometric choice. However fingerprint biometrics is showing limitations. Since fingerp...

  14. Bilateral meandering pulmonary veins

    Energy Technology Data Exchange (ETDEWEB)

    Thupili, Chakradhar R.; Udayasankar, Unni [Pediatric Imaging, Imaging Institute Cleveland Clinic, Cleveland, OH (United States); Renapurkar, Rahul [Imaging Institute Cleveland Clinic, Thoracic Imaging, L10, Cleveland, OH (United States)

    2015-06-15

    Meandering pulmonary veins is a rare clinical entity that can be mistaken for more complex congenital syndromes such as hypogenetic lung syndrome. We report imaging findings in a rare incidentally detected case of bilateral meandering pulmonary veins. We briefly discuss the role of imaging in diagnosing this condition, with particular emphasis on contrast-enhanced CT. (orig.)

  15. Deep Vein Thrombosis

    African Journals Online (AJOL)

    OWNER

    Deep Vein Thrombosis: Risk Factors and Prevention in Surgical Patients. Deep Vein ... preventable morbidity and mortality in hospitalized surgical patients. ... the elderly.3,4 It is very rare before the age ... depends on the risk level; therefore an .... but also in the post-operative period. ... is continuing uncertainty regarding.

  16. Compressed sensing approach for wrist vein biometrics.

    Science.gov (United States)

    Lantsov, Aleksey; Ryabko, Maxim; Shchekin, Aleksey

    2018-04-01

    The work describes features of the compressed sensing (CS) approach utilized for development of a wearable system for wrist vein recognition with single-pixel detection; we consider this system useful for biometrics authentication purposes. The CS approach implies use of a spatial light modulation (SLM) which, in our case, can be performed differently-with a liquid crystal display or diffusely scattering medium. We show that compressed sensing combined with above-mentioned means of SLM allows us to avoid using an optical system-a limiting factor for wearable devices. The trade-off between the 2 different SLM approaches regarding issues of practical implementation of CS approach for wrist vein recognition purposes is discussed. A possible solution of a misalignment problem-a typical issue for imaging systems based upon 2D arrays of photodiodes-is also proposed. Proposed design of the wearable device for wrist vein recognition is based upon single-pixel detection. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Preventing Deep Vein Thrombosis

    Science.gov (United States)

    ... Physicians Contact Us My ACOG ACOG Departments Donate Shop Career Connection Home Clinical Guidance & Publications Practice Management ... skin. A clot also can form if blood flow is too slow the lining of a vein ...

  18. Palm-vein classification based on principal orientation features.

    Directory of Open Access Journals (Sweden)

    Yujia Zhou

    Full Text Available Personal recognition using palm-vein patterns has emerged as a promising alternative for human recognition because of its uniqueness, stability, live body identification, flexibility, and difficulty to cheat. With the expanding application of palm-vein pattern recognition, the corresponding growth of the database has resulted in a long response time. To shorten the response time of identification, this paper proposes a simple and useful classification for palm-vein identification based on principal direction features. In the registration process, the Gaussian-Radon transform is adopted to extract the orientation matrix and then compute the principal direction of a palm-vein image based on the orientation matrix. The database can be classified into six bins based on the value of the principal direction. In the identification process, the principal direction of the test sample is first extracted to ascertain the corresponding bin. One-by-one matching with the training samples is then performed in the bin. To improve recognition efficiency while maintaining better recognition accuracy, two neighborhood bins of the corresponding bin are continuously searched to identify the input palm-vein image. Evaluation experiments are conducted on three different databases, namely, PolyU, CASIA, and the database of this study. Experimental results show that the searching range of one test sample in PolyU, CASIA and our database by the proposed method for palm-vein identification can be reduced to 14.29%, 14.50%, and 14.28%, with retrieval accuracy of 96.67%, 96.00%, and 97.71%, respectively. With 10,000 training samples in the database, the execution time of the identification process by the traditional method is 18.56 s, while that by the proposed approach is 3.16 s. The experimental results confirm that the proposed approach is more efficient than the traditional method, especially for a large database.

  19. Pelvic Vein Embolisation in the Management of Varicose Veins

    International Nuclear Information System (INIS)

    Ratnam, Lakshmi A.; Marsh, Petra; Holdstock, Judy M.; Harrison, Charmaine S.; Hussain, Fuad F.; Whiteley, Mark S.; Lopez, Anthony

    2008-01-01

    Pelvic vein incompetence is common in patients with atypical varicose veins, contributing to their recurrence after surgery. Therefore, refluxing pelvic veins should be identified and treated. We present our experience with pelvic vein embolisation in patients presenting with varicose veins. Patients presenting with varicose veins with a duplex-proven contribution from perivulval veins undergo transvaginal duplex sonography (TVUS) to identify refluxing pelvic veins. Those with positive scans undergo embolisation before surgical treatment of their lower limb varicose veins. A total of 218 women (mean age of 46.3 years) were treated. Parity was documented in the first 60 patients, of whom 47 (78.3%) were multiparous, 11 (18.3%) had had one previous pregnancy, and 2 (3.3%) were nulliparous. The left ovarian vein was embolised in 78%, the right internal iliac in 64.7%, the left internal iliac in 56.4%, and the right ovarian vein in 42.2% of patients. At follow-up TVUS, mild reflux only was seen in 16, marked persistent reflux in 6, and new reflux in 3 patients. These 9 women underwent successful repeat embolisation. Two patients experienced pulmonary embolisation of the coils, of whom 1 was asymptomatic and 1 was successfully retrieved; 1 patient had a misplaced coil protruding into the common femoral vein; and 1 patient had perineal thrombophlebitis. The results of our study showed that pelvic venous embolisation by way of a transjugular approach is a safe and effective technique in the treatment of pelvic vein reflux.

  20. Stiff Hands

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is a Hand Surgeon? What is a Hand Therapist? Media Find a Hand Surgeon Home Anatomy Stiff Hands Email to a friend * required fields ...

  1. Hand Infections

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is a Hand Surgeon? What is a Hand Therapist? Media Find a Hand Surgeon Home Anatomy Hand Infections Email to a friend * required fields ...

  2. Postura da mão e imagética motora: um estudo sobre reconhecimento de partes do corpo Hand posture and motor imagery: a body-part recognition study

    Directory of Open Access Journals (Sweden)

    AP Lameira

    2008-10-01

    Full Text Available OBJETIVOS: Assim como a imagética motora, o reconhecimento de partes do corpo aciona representações somatosensoriais específicas. Essas representações são ativadas implicitamente para comparar o corpo com o estímulo. No presente estudo, investigou-se a influência da informação proprioceptiva da postura no reconhecimento de partes do corpo (mãos e propõe-se a utilização dessa tarefa na reabilitação de pacientes neurológicos. MATERIAIS E MÉTODOS: Dez voluntários destros participaram do experimento. A tarefa era reconhecer a lateralidade de figuras da mão apresentada, em várias perspectivas e em vários ângulos de orientação. Para a figura da mão direita, o voluntário pressionava a tecla direita e para a figura da mão esquerda, a tecla esquerda. Os voluntários realizavam duas sessões: uma com as mãos na postura prona e outra com as mãos na postura supina. RESULTADOS: Os tempos de reação manual (TRM eram maiores para as vistas e orientações, nas quais é difícil realizar o movimento real, mostrando que durante a tarefa, existe um acionamento de representações motoras para comparar o corpo com o estímulo. Além disso, existe uma influência da postura do sujeito em vistas e ângulos específicos. CONCLUSÕES: Estes resultados mostram que representações motoras são ativadas para comparar o corpo com o estímulo e que a postura da mão influencia esta ressonância entre estímulo e parte do corpo.OBJECTIVE: Recognition of body parts activates specific somatosensory representations in a way that is similar to motor imagery. These representations are implicitly activated to compare the body with the stimulus. In the present study, we investigate the influence of proprioceptive information relating to body posture on the recognition of body parts (hands. It proposes that this task could be used for rehabilitation of neurological patients. METHODS: Ten right-handed volunteers participated in this experiment. The

  3. The vein collar

    DEFF Research Database (Denmark)

    Lundgren, F; Schroeder, Torben Veith

    2012-01-01

    Randomized studies evaluating the effect of a vein collar at the distal anastomosis of PTFE-grafts show conflicting results. The study of the Joint Vascular Research Group (JVRG) of UK found improved primary patency while the Scandinavian Miller Collar Study (SCAMICOS) found neither any effect...

  4. Deep Vein Thrombosis

    Centers for Disease Control (CDC) Podcasts

    2012-04-05

    This podcast discusses the risk for deep vein thrombosis in long-distance travelers and ways to minimize that risk.  Created: 4/5/2012 by National Center for Emerging and Zoonotic Infectious Diseases (NCEZID).   Date Released: 4/5/2012.

  5. [Deep vein thrombosis prophylaxis.

    Science.gov (United States)

    Sandoval-Chagoya, Gloria Alejandra; Laniado-Laborín, Rafael

    2013-01-01

    Background: despite the proven effectiveness of preventive therapy for deep vein thrombosis, a significant proportion of patients at risk for thromboembolism do not receive prophylaxis during hospitalization. Our objective was to determine the adherence to thrombosis prophylaxis guidelines in a general hospital as a quality control strategy. Methods: a random audit of clinical charts was conducted at the Tijuana General Hospital, Baja California, Mexico, to determine the degree of adherence to deep vein thrombosis prophylaxis guidelines. The instrument used was the Caprini's checklist for thrombosis risk assessment in adult patients. Results: the sample included 300 patient charts; 182 (60.7 %) were surgical patients and 118 were medical patients. Forty six patients (15.3 %) received deep vein thrombosis pharmacologic prophylaxis; 27.1 % of medical patients received deep vein thrombosis prophylaxis versus 8.3 % of surgical patients (p < 0.0001). Conclusions: our results show that adherence to DVT prophylaxis at our hospital is extremely low. Only 15.3 % of our patients at risk received treatment, and even patients with very high risk received treatment in less than 25 % of the cases. We have implemented strategies to increase compliance with clinical guidelines.

  6. A Kinect-Based Sign Language Hand Gesture Recognition System for Hearing- and Speech-Impaired: A Pilot Study of Pakistani Sign Language.

    Science.gov (United States)

    Halim, Zahid; Abbas, Ghulam

    2015-01-01

    Sign language provides hearing and speech impaired individuals with an interface to communicate with other members of the society. Unfortunately, sign language is not understood by most of the common people. For this, a gadget based on image processing and pattern recognition can provide with a vital aid for detecting and translating sign language into a vocal language. This work presents a system for detecting and understanding the sign language gestures by a custom built software tool and later translating the gesture into a vocal language. For the purpose of recognizing a particular gesture, the system employs a Dynamic Time Warping (DTW) algorithm and an off-the-shelf software tool is employed for vocal language generation. Microsoft(®) Kinect is the primary tool used to capture video stream of a user. The proposed method is capable of successfully detecting gestures stored in the dictionary with an accuracy of 91%. The proposed system has the ability to define and add custom made gestures. Based on an experiment in which 10 individuals with impairments used the system to communicate with 5 people with no disability, 87% agreed that the system was useful.

  7. Collateral veins in left renal vein stenosis demonstrated via CT

    Energy Technology Data Exchange (ETDEWEB)

    Lien, H.H.; Lund, G.; Talle, K.

    1983-02-01

    Twelve patients with left renal vein stenosis from tumor compression were studied with CT. All had distended collateral veins in the perirenal space which either formed a radiating or a cobweb pattern or appeared as marked longitudinal veins. Inferior phrenic vein branches were seen in seven patients and were considerably enlarged in two. Other major veins possibly taking part in collateral circulation could not be recognized due to obliteration of fat planes. The renal fascia was thickened in eleven patients, probably due to edema. A close study of the perirenal space with CT may give valuable information about collateral development.

  8. Collateral veins in left renal vein stenosis demonstrated via CT

    International Nuclear Information System (INIS)

    Lien, H.H.; Lund, G.; Talle, K.

    1983-01-01

    Twelve patients with left renal vein stenosis from tumor compression were studied with CT. All had distended collateral veins in the perirenal space which either formed a radiating or a cobweb pattern or appeared as marked longitudinal veins. Inferior phrenic vein branches were seen in seven patients and were considerably enlarged in two. Other major veins possibly taking part in collateral circulation could not be recognized due to obliteration of fat planes. The renal fascia was thickened in eleven patients, probably due to edema. A close study of the perirenal space with CT may give valuable information about collateral development. (orig.)

  9. Concerns and Discomforts of Pregnancy - Varicose Veins

    Science.gov (United States)

    Concerns and Discomforts of Pregnancy - Varicose Veins Varicose veins are enlarged veins you may see on your ... Healthy Roads Media project www. healthyroadsmedia. org English - Concerns and Discomforts of Pregnancy (Varicose Veins) Last reviewed ...

  10. Hand Fractures

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is ... Hand Therapist? Media Find a Hand Surgeon Home Anatomy ... DESCRIPTION The bones of the hand serve as a framework. This framework supports the muscles that make the wrist and fingers move. When ...

  11. Anatomical variation of the main and right portal vein on indirect portogram : correlated with CT and hepatic angiogram

    International Nuclear Information System (INIS)

    Park, Won Kyu; Chang, Jae Chun; Bae, Kyoung Kug; Cho, Jae Ho

    1996-01-01

    To describe variations of the main and right portal veins as visualized by indirect portograms and to examine the surgical implications of these findings. A retrospective review was conducted of 632 indirect portograms of 632 patients in whom third-order branches were visualized. All patients also underwent dynamic CT and AP and oblique hepatic angiography. Variations of the main portal vein were found in 165 patients(26.1%) and involned an immediate trifurcation of the main portal vein in 102 patients(16.1%), early division of the right posterior portal vein in 53(8.4%), simultaneous division into four branches in three (0.5%), five branches in two (0.3%), a replaced P4 originating from the right portal vein in two (0.3%), and an accessory P6 originating from the main portal vein, a replaced P6 originating from the main protal vein, or a replaced left lateral portal vein originating from the right portal vein in one (0.2%), respectively. Of 468 patients who had a common right portal vein, absence of the right posterior portal vein was seen in 26 patients(5.6%) and an accessory subsegmental branch originating from the right portal vein in 17 patients(3.6%). Recognition of such variations of the portal vein assists in the localization and apperciation of the hepatic segmental anatomy, in preoperative evaluations for hepatic resections, and in radiologic interventional procedures through the portal vein

  12. Interposition vein cuffs.

    Science.gov (United States)

    Harris, P; Da Silva, T; How, T

    1996-01-01

    A vein cuff interposed at the distal anastomosis between a prosthetic vascular graft and a recipient infrageniculate artery improves the chances of continued patency of the graft, at least in the short and medium term. The mode of effect appears to be suppression or modification of anastomotic myointimal hyperplasia (MIH). In the event of graft failure the recipient artery and run-off vessels remain free from MIH and their patency is preserved thereby improving the prospects for further vascular reconstruction and limb salvage. The mechanisms by which interposition vein cuffs might modulate MIH are reviewed. Experimental evidence is described to show that the geometry of a cuffed anastomosis promotes a characteristic haemodynamic flow structure with a stable vortex. It is suggested that this vortex exerts greater shear stress upon the wall of the artery than the normal laminar flow observed in conventional anastomoses. High shear stress is known to inhibit MIH.

  13. Accessory hepatic vein: MR imaging

    International Nuclear Information System (INIS)

    Lee, Chang Hee; Rho, Tack Soo; Cha, Sang Hoon; Park, Cheol Min; Cha, In Ho

    1995-01-01

    To evaluate the MR appearance of the accessory hepatic veins. The study included 87 consecutive patients for whom abdominal MR images were obtained. The subjects who had liver lesion or hepatic vascular abnormalities were excluded. Couinaud classified accessory hepatic veins into inferior and middle right hepatic veins. Our major interests were evaluation of the incidence, morphology, and location of the accessory hepatic vein. Inferior right hepatic vein was demonstrated in 43 out of 87 patients (49%). The morphology was linear in 35 patients (80.5%), and V-shaped in 8 patients (19.5%). In 40 patients (93%), the inferior right hepatic vein was located in the posteroinferior aspect of the right lobe. Middle right hepatic vein was demonstrated in 7 out of 87 patients (8%). All were single linear in morphology, combined with the inferior right hepatic vein, and located between the right hepatic vein and inferior right hepatic vein. The accessory hepatic vein was demonstrated in 49% among the Korean adult population, and was located in posteroinferior portion of the liver, in 93%

  14. Plantar vein thrombosis: a rare cause of plantar foot pain

    International Nuclear Information System (INIS)

    Siegal, Daniel S.; Wu, Jim S.; Brennan, Darren D.; Hochman, Mary G.; Challies, Tracy

    2008-01-01

    Plantar vein thrombosis is a rare condition, with only a handful of cases reported in the literature. The cause is unknown; however, the disease has been attributed to prior surgery, trauma, and paraneoplastic conditions. We present a case of a 32-year-old female runner with plantar vein thrombosis diagnosed on contrast-enhanced MRI and confirmed on ultrasound. The symptoms resolved with conservative treatment and evaluation revealed the presence of a prothrombin gene mutation and use of oral contraceptive pills. To our knowledge, this is the first case of plantar vein thrombosis diagnosed initially by MRI. Moreover, this case suggests that plantar vein thrombosis should be considered in patients with hypercoagulable states and plantar foot pain. (orig.)

  15. Plantar vein thrombosis: a rare cause of plantar foot pain

    Energy Technology Data Exchange (ETDEWEB)

    Siegal, Daniel S.; Wu, Jim S.; Brennan, Darren D.; Hochman, Mary G. [Beth Israel Deaconess Medical Center, Department of Radiology, Boston, MA (United States); Challies, Tracy [Beth Israel Deaconess Medical Center, Department of Pathology, Boston, MA (United States)

    2008-03-15

    Plantar vein thrombosis is a rare condition, with only a handful of cases reported in the literature. The cause is unknown; however, the disease has been attributed to prior surgery, trauma, and paraneoplastic conditions. We present a case of a 32-year-old female runner with plantar vein thrombosis diagnosed on contrast-enhanced MRI and confirmed on ultrasound. The symptoms resolved with conservative treatment and evaluation revealed the presence of a prothrombin gene mutation and use of oral contraceptive pills. To our knowledge, this is the first case of plantar vein thrombosis diagnosed initially by MRI. Moreover, this case suggests that plantar vein thrombosis should be considered in patients with hypercoagulable states and plantar foot pain. (orig.)

  16. Vein grafting in fingertip replantations.

    Science.gov (United States)

    Yan, Hede; Jackson, William D; Songcharoen, Somjade; Akdemir, Ovunc; Li, Zhijie; Chen, Xinglong; Jiang, Liangfu; Gao, Weiyang

    2009-01-01

    In this retrospective study, the survival rates of fingertip replantation with and without vein grafting were evaluated along with their postoperative functional and cosmetic results. One hundred twenty-one-fingertip amputations were performed in 103 patients between September 2002 and July 2007. Thirty-four amputated fingertips were replanted without vein grafting, while 87 amputated fingertips were replanted with vein grafting for arterial and/or venous repairs. The overall survival rates of the replantations with and without vein grafting were 90% (78/87) and 85% (29/34), respectively. The survival rates were 88% (36/41) with venous repair, 93% (25/27) with arterial repair, and 89% (17/19) with both. Nineteen patients without vein grafting and 48 patients with vein grafting had a follow-up period of more than one year. Good cosmetic and functional outcomes were observed in both groups of patients. The results show that vein grafting is a reliable technique in fingertip replantations, showing no significant difference (P > 0.05) in survival between those with and without vein grafting. Furthermore, no significant difference (P > 0.05) in survival was found between cases with vein grafts for arterial and/or venous repairs. In fingertip replantations with vein grafting, favorable functional and esthetic results can be achieved without sacrificing replantation survival. (c) 2009 Wiley-Liss, Inc.

  17. Hand Therapy

    Science.gov (United States)

    ... from conditions such as carpal tunnel syndrome and tennis elbow , as well as from chronic problems such as ... Tools Advice from a Certified Hand Therapist on Tennis Elbow Advice from a Certified Hand Therapist: Living with( ...

  18. Hand Anatomy

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is ... Hand Therapist? Media Find a Hand Surgeon Home Anatomy Bones Joints Muscles Nerves Vessels Tendons Anatomy The upper extremity is ...

  19. [Hand osteoarthritis].

    Science.gov (United States)

    Šenolt, Ladislav

    Hand osteoarthritis (OA) is a common chronic disorder causing pain and limitation of mobility of affected joints. The prevalence of hand OA increases with age and more often affects females. Clinical signs obviously do not correlate with radiographic findings - symptomatic hand OA affects approximately 26 % of adult subjects, but radiographic changes can be found in up to two thirds of females and half of males older than 55 years.Disease course differ among individual patients. Hand OA is a heterogeneous disease. Nodal hand OA is the most common subtype affecting interphalangeal joints, thumb base OA affects first carpometacarpal joint. Erosive OA represents a specific subtype of hand OA, which is associated with joint inflammation, more pain, functional limitation and erosive findings on radiographs.Treatment of OA is limited. Analgesics and nonsteroidal anti-inflammatory drugs are the only agents reducing symptoms. New insights into the pathogenesis of disease should contribute to the development of novel effective treatment of hand OA.

  20. Leiomyosarcoma of the renal vein

    Directory of Open Access Journals (Sweden)

    Lemos Gustavo C.

    2003-01-01

    Full Text Available Leiomyosarcoma of the renal vein is a rare tumor of complex diagnosis. We presented a case of renal vein leiomyosarcoma detected in a routine study. The primary treatment was complete surgical removal of the mass. In cases where surgical removal is not possible the prognosis is poor, with high rates of local recurrence and distant spread.

  1. Vein type uranium deposits

    International Nuclear Information System (INIS)

    1986-01-01

    Veins are tabular- or sheet-like masses of minerals occupying or following a fracture or a set of fractures in the enclosing rock. They have been formed later than the country rock and fractures, either by filling of the open spaces or by partial or complete replacement of the adjoining rock or most commonly by both of these processes combined. This volume begins with the occurrences and deposits known from old shield areas and the sedimentary belts surrounding them. They are followed by papers describing the European deposits mostly of Variscan age, and by similar deposits known from China being of Jurassic age. The volume is completed by two papers which do not fit exactly in the given scheme. A separate abstract was prepared for each of the 25 papers in this report

  2. The economics of vein disease.

    Science.gov (United States)

    Sales, Clifford M; Podnos, Joan; Levison, Jonathan

    2007-09-01

    The management of cosmetic vein problems requires a very different approach than that for the majority of most other vascular disorders that occur in a vascular surgery practice. This article focuses on the business aspects of a cosmetic vein practice, with particular attention to the uniqueness of these issues. Managing patient expectations is critical to the success of a cosmetic vein practice. Maneuvering within the insurance can be difficult and frustrating for both the patient and the practice. Practices should use cost accounting principles to evaluate the success of their vein work. Vein surgery--especially if performed within the office--can undergo an accurate break-even analysis to determine its profitability.

  3. Robotic Hand

    Science.gov (United States)

    1993-01-01

    The Omni-Hand was developed by Ross-Hime Designs, Inc. for Marshall Space Flight Center (MSFC) under a Small Business Innovation Research (SBIR) contract. The multiple digit hand has an opposable thumb and a flexible wrist. Electric muscles called Minnacs power wrist joints and the interchangeable digits. Two hands have been delivered to NASA for evaluation for potential use on space missions and the unit is commercially available for applications like hazardous materials handling and manufacturing automation. Previous SBIR contracts resulted in the Omni-Wrist and Omni-Wrist II robotic systems, which are commercially available for spray painting, sealing, ultrasonic testing, as well as other uses.

  4. Varicose Vein Treatment (Endovenous Ablation of Varicose Veins)

    Science.gov (United States)

    ... associated veins. top of page What are the benefits vs. risks? Benefits No surgical incision is needed—only a small ... risk of infection. The chance of infection requiring antibiotic treatment appears to be less than one in ...

  5. Thrombosis of right ovarian vein

    International Nuclear Information System (INIS)

    Forner, J.; Talens, A.; Flores, M.; Mendez, M.

    2001-01-01

    Ovarian vein thrombosis is a rare postpartum complication (0.1%). It can be fatal, since it can lead to sepsis, pulmonary thromboembolisms and inferior vena cava or renal vein thrombosis. Computed tomography and magnetic resonance imaging are the techniques of choice for its diagnosis, while the value of ultrasound is limited due to its low sensitivity and specificity. We report the case of a woman who, during puerperium, developed thrombosis of right ovarian vein that presented clinical, ultrasonographic and computed tomographic features of appendicitis. We describe the radiological sings and stress the fact that this diagnosis should be suspected in puerperal women. (Author) 9 refs

  6. Side-View Face Recognition

    NARCIS (Netherlands)

    Santemiz, P.; Spreeuwers, Lieuwe Jan; Veldhuis, Raymond N.J.; van den Biggelaar, Olivier

    As a widely used biometrics, face recognition has many advantages such as being non-intrusive, natural and passive. On the other hand, in real-life scenarios with uncontrolled environment, pose variation up to side-view positions makes face recognition a challenging work. In this paper we discuss

  7. Pattern recognition

    CERN Document Server

    Theodoridis, Sergios

    2003-01-01

    Pattern recognition is a scientific discipline that is becoming increasingly important in the age of automation and information handling and retrieval. Patter Recognition, 2e covers the entire spectrum of pattern recognition applications, from image analysis to speech recognition and communications. This book presents cutting-edge material on neural networks, - a set of linked microprocessors that can form associations and uses pattern recognition to ""learn"" -and enhances student motivation by approaching pattern recognition from the designer's point of view. A direct result of more than 10

  8. Hand eczema

    DEFF Research Database (Denmark)

    Ibler, K.S.; Jemec, G.B.E.; Flyvholm, M.-A.

    2012-01-01

    Background. Healthcare workers are at increased risk of developing hand eczema. Objectives. To investigate the prevalence and severity of self-reported hand eczema, and to relate the findings to demographic data, occupation, medical speciality, wards, shifts, and working hours. Patients/materials......Background. Healthcare workers are at increased risk of developing hand eczema. Objectives. To investigate the prevalence and severity of self-reported hand eczema, and to relate the findings to demographic data, occupation, medical speciality, wards, shifts, and working hours. Patients...... dermatitis, younger age, male sex (male doctors), and working hours. Eighty nine per cent of subjects reported mild/moderate lesions. Atopic dermatitis was the only factor significantly related to severity. Sick leave was reported by 8% of subjects, and notification to the authorities by 12%. Conclusions...... or severity, but cultural differences between professions with respect to coping with the eczema were significant. Atopic dermatitis was related to increased prevalence and severity, and preventive efforts should be made for healthcare workers with atopic dermatitis....

  9. Hand Osteoblastoma

    Directory of Open Access Journals (Sweden)

    M. Farzan

    2006-06-01

    Full Text Available Background and Aim: Osteoblastoma is one of the rarest primary bone tumors. Although, small bones of the hands and feet are the third most common location for this tumor, the hand involvement is very rare and few case observations were published in the English-language literature. Materials and Methods: In this study, we report five cases of benign osteoblastoma of the hand, 3 in metacarpals and two in phalanxes. The clinical feature is not specific. The severe nocturnal, salicylate-responsive pain is not present in patients with osteoblastoma. The pain is dull, persistent and less localized. The clinical course is usually long and there is often symptoms for months before medical attention are sought. Swelling is a more persistent finding in osteoblastoma of the hand that we found in all of our patients. The radiologic findings are indistinctive, so preoperative diagnosis based on X-ray appearance is difficult. In all of our 5 cases, we fail to consider osteoblastoma as primary diagnosis. Pathologically, osteoblastoma consisting of a well-vascularized connective tissue stroma in which there is active production of osteoid and primitive woven bone. Treatment depends on the stage and localization of the tumor. Curettage and bone grafting is sufficient in stage 1 or stage 2, but in stage 3 wide resection is necessary for prevention of recurrence. Osteosarcoma is the most important differential diagnosis that may lead to inappropriate operation.

  10. Multimodal biometric method that combines veins, prints, and shape of a finger

    Science.gov (United States)

    Kang, Byung Jun; Park, Kang Ryoung; Yoo, Jang-Hee; Kim, Jeong Nyeo

    2011-01-01

    Multimodal biometrics provides high recognition accuracy and population coverage by using various biometric features. A single finger contains finger veins, fingerprints, and finger geometry features; by using multimodal biometrics, information on these multiple features can be simultaneously obtained in a short time and their fusion can outperform the use of a single feature. This paper proposes a new finger recognition method based on the score-level fusion of finger veins, fingerprints, and finger geometry features. This research is novel in the following four ways. First, the performances of the finger-vein and fingerprint recognition are improved by using a method based on a local derivative pattern. Second, the accuracy of the finger geometry recognition is greatly increased by combining a Fourier descriptor with principal component analysis. Third, a fuzzy score normalization method is introduced; its performance is better than the conventional Z-score normalization method. Fourth, finger-vein, fingerprint, and finger geometry recognitions are combined by using three support vector machines and a weighted SUM rule. Experimental results showed that the equal error rate of the proposed method was 0.254%, which was lower than those of the other methods.

  11. Non Audio-Video gesture recognition system

    DEFF Research Database (Denmark)

    Craciunescu, Razvan; Mihovska, Albena Dimitrova; Kyriazakos, Sofoklis

    2016-01-01

    Gesture recognition is a topic in computer science and language technology with the goal of interpreting human gestures via mathematical algorithms. Gestures can originate from any bodily motion or state but commonly originate from the face or hand. Current research focus includes on the emotion...... recognition from the face and hand gesture recognition. Gesture recognition enables humans to communicate with the machine and interact naturally without any mechanical devices. This paper investigates the possibility to use non-audio/video sensors in order to design a low-cost gesture recognition device...

  12. Benign Angiomyolipoma with Renal Vein Invasion: A Case Report

    International Nuclear Information System (INIS)

    Kim, Mi Seon; Park, Soo Youn; Hwang, Seong Su

    2009-01-01

    Angiomyolipomas are the most common type of benign renal tumors and are characterized by a mixture of mature adipose tissue, sheet of smooth muscle, and thick-walled blood vessels of various proportions. Several cases of angiomyolipoma with partial malignant transformation invading the adjacent structure and lymph node have been reported. On the other hand, benign angiomyolipomas invading the adjacent structures has been rarely reported. We report a case of a benign angiomyolipoma with renal vein invasion

  13. Adrenal vein catheterization. Anatomic considerations

    Energy Technology Data Exchange (ETDEWEB)

    El-Sherief, M.A. (Akademiska Sjukhuset, Uppsala (Sweden))

    1982-01-01

    Twenty post-mortem specimens and 93 phlebographies (56 right side, 37 left side) from 44 patients were investigated with respect to the adrenal venous anatomy. At autopsy, the venous orifices displayed in the area of adrenal drainage were injected bilaterally to identify the adrenal vein(s), the surrounding channels and the presence of interconnections. The findings were correlated with those at clinical phlebography, and the different sources of error were elicited. These were mainly found on the right side. Some guidelines are suggested in the hope that these will contribute to eliminate misconceptions.

  14. Verification Image of The Veins on The Back Palm with Modified Local Line Binary Pattern (MLLBP) and Histogram

    Science.gov (United States)

    Prijono, Agus; Darmawan Hangkawidjaja, Aan; Ratnadewi; Saleh Ahmar, Ansari

    2018-01-01

    The verification to person who is used today as a fingerprint, signature, personal identification number (PIN) in the bank system, identity cards, attendance, easily copied and forged. This causes the system not secure and is vulnerable to unauthorized persons to access the system. In this research will be implemented verification system using the image of the blood vessels in the back of the palms as recognition more difficult to imitate because it is located inside the human body so it is safer to use. The blood vessels located at the back of the human hand is unique, even humans twins have a different image of the blood vessels. Besides the image of the blood vessels do not depend on a person’s age, so it can be used for long term, except in the case of an accident, or disease. Because of the unique vein pattern recognition can be used in a person. In this paper, we used a modification method to perform the introduction of a person based on the image of the blood vessel that is using Modified Local Line Binary Pattern (MLLBP). The process of matching blood vessel image feature extraction using Hamming Distance. Test case of verification is done by calculating the percentage of acceptance of the same person. Rejection error occurs if a person was not matched by the system with the data itself. The 10 person with 15 image compared to 5 image vein for each person is resulted 80,67% successful Another test case of the verification is done by verified two image from different person that is forgery, and the verification will be true if the system can rejection the image forgery. The ten different person is not verified and the result is obtained 94%.

  15. Neurological sequelae from brachiocephalic vein stenosis.

    Science.gov (United States)

    Herzig, David W; Stemer, Andrew B; Bell, Randy S; Liu, Ai-Hsi; Armonda, Rocco A; Bank, William O

    2013-05-01

    Stenosis of central veins (brachiocephalic vein [BCV] and superior vena cava) occurs in 30% of hemodialysis patients, rarely producing intracranial pathology. The authors present the first cases of BCV stenosis causing perimesencephalic subarachnoid hemorrhage and myoclonic epilepsy. In the first case, a 73-year-old man on hemodialysis presented with headache and blurry vision, and was admitted with presumed idiopathic intracranial hypertension after negative CT studies and confirmatory lumbar puncture. The patient mildly improved until hospital Day 3, when he experienced a seizure; emergency CT scans showed perimesencephalic subarachnoid hemorrhage. Cerebral angiography failed to find any vascular abnormality, but demonstrated venous congestion. A fistulogram found left BCV occlusion with jugular reflux. The occlusion could not be reopened percutaneously and required open fistula ligation. Postoperatively, symptoms resolved and the patient remained intact at 7-month follow-up. In the second case, a 67-year-old woman on hemodialysis presented with right arm weakness and myoclonic jerks. Admission MRI revealed subcortical edema and a possible dural arteriovenous fistula. Cerebral angiography showed venous engorgement, but no vascular malformation. A fistulogram found left BCV stenosis with jugular reflux, which was immediately reversed with angioplasty and stent placement. Postprocedure the patient was seizure free, and her strength improved. Seven months later the patient presented in myoclonic status epilepticus, and a fistulogram revealed stent occlusion. Angioplasty successfully reopened the stent and she returned to baseline; she was seizure free at 4-month follow-up. Central venous stenosis is common with hemodialysis, but rarely presents with neurological findings. Prompt recognition and endovascular intervention can restore normal venous drainage and resolve symptoms.

  16. Multiscale Convolutional Neural Networks for Hand Detection

    Directory of Open Access Journals (Sweden)

    Shiyang Yan

    2017-01-01

    Full Text Available Unconstrained hand detection in still images plays an important role in many hand-related vision problems, for example, hand tracking, gesture analysis, human action recognition and human-machine interaction, and sign language recognition. Although hand detection has been extensively studied for decades, it is still a challenging task with many problems to be tackled. The contributing factors for this complexity include heavy occlusion, low resolution, varying illumination conditions, different hand gestures, and the complex interactions between hands and objects or other hands. In this paper, we propose a multiscale deep learning model for unconstrained hand detection in still images. Deep learning models, and deep convolutional neural networks (CNNs in particular, have achieved state-of-the-art performances in many vision benchmarks. Developed from the region-based CNN (R-CNN model, we propose a hand detection scheme based on candidate regions generated by a generic region proposal algorithm, followed by multiscale information fusion from the popular VGG16 model. Two benchmark datasets were applied to validate the proposed method, namely, the Oxford Hand Detection Dataset and the VIVA Hand Detection Challenge. We achieved state-of-the-art results on the Oxford Hand Detection Dataset and had satisfactory performance in the VIVA Hand Detection Challenge.

  17. CT findings of portal vein aneurysm

    International Nuclear Information System (INIS)

    Yang, Dal Mo; Chang, Mi Son; Yoon, Myung Hwan; Kim, Hak Soo; Kim, Hyung Sik; Chung, Hyo Sun; Chung, Jin Woo

    1999-01-01

    To describe the CT findings of portal vein aneurysm in eight patients. All patients included in this study (two men and six women) underwent CT examinations between October 1996 and June1998. Of these eight, three were suffering from hepatic disease and portal hypertension. We determined the location, shape, size, and characteristics of the lesions, and the presence or absence of portal vein anomaly. Seven patients had intrahepatic portal vein aneurysm (at the umbilical portion of the left portal vein in five patients, between the transverse and umbilical portion of the left portal vein in one, and at the bifurcation of the anterior and posterior branch of the right portal vein in one), while extrahepatic portal vein aneurysm, at the confluence of the superior mesenteric and splenic vein was found in only one. Lesions were cyst-shaped in seven cases and saccular in one, and showed well-circumscribed, markedly enhanced mass, which communicated with the portal vein and/or gives off major branches. Portal vein anomaly, in which the right anterior segmental portal vein originated from the umbilical portion of the left portal vein, was seen in three patients. In all three, intrahepatic portal vein aneurysm was present at the umbilical portion of the left portal vein, and in one, the umbilical protion of the left portal vein was located to the right of the Cantlic line. CT examination can help reveal portal vein aneurysm by detecting a well-circumscribed, markedly enhanced mass which communicates with the portal vein and/or gives off major branches

  18. Congestive index of portal vein

    International Nuclear Information System (INIS)

    Kim, Won Ho; Kim, H. K.; Lee, S. C.; Han, S. H.; Han, K. H.; Chung, J. B.; Choi, H. J.

    1989-01-01

    In patients with portal hypertension, the blood flow volume is maintained despite decreased blood flow velocity due to enlargement of the vascular cross sectional area. Thus, the 'congestion index' of the portal vein, which is the ratio between the cross sectional area (cm2) and the blood flow velocity (cm/sec) determined by a Doppler ultrasonography, may be a sensitive index by which to assess portal hypertension. We performed Doppler ultrasonography on 24 normal subjects, 14 patients with biopsy proved chronic active hepatitis and 55 patients with liver cirrhosis in order to assess the diagnostic value of the congestion index. The cross sectional area of the portal vein was significantly enlarged and the mean blood flow velocity was significantly reduced in patients with liver cirrhosis compared with controls. However, the blood flow volume was no difference. The congestion index of the portal vein was significantly increased in patients with liver cirrhosis (0.113+0.035) compared with patients with chronic active hepatitis(0.078+0.029) (p<0.001) and controls (0.053+0.016) (p<0.001). The sensitivity, specificity and predictability of the congestion index for detection of patients with the cirrhosis of the liver were 76.4%, 100% and 100% respectively, when the normal range was set at mean+2SD. The results suggest that the congestion index of the portal vein may pla a significant role in diagnosis of portal hypertensive patients

  19. Kinetics of vein graft hyperplasia

    International Nuclear Information System (INIS)

    Zwolak, R.M.; Adams, M.C.; Clowes, A.W.

    1986-01-01

    Human aortocoronary vein grafts fail due to accelerated occlusive disease. The possibility that this is related to cellular hyperplasia was investigated in a rabbit model where kinetics of vein graft thickening, endothelial (EC) repair, and smooth muscle cell (SMC) proliferation were measured from 2 days to 24 weeks after implanting jugular vein segments in the carotid artery. Immediately after graft placement focal EC denudation was observed. These defects were repaired within 1 week and did not recur. By 4 weeks intimal area had increased 30 fold from 0.028 +/- 0.004 to 0.705 +/- 0.021 mm 2 , and a 24 weeks was 0.93 +/- 0.21 mm 2 . This response did not produce a reduction in graft lumen area. EC and SMC thymidine-labeling index were measured by en face and cross-section autoradiography after injection of 3 H-thymidine and perfusion fixation. Despite rapid EC surface repair EC labeling index remained elevated and only returned to normal levels at 12 weeks; SMC labeling was 10 fold greater than baseline even at 24 weeks (0.22% vs 0.02%). SMC mass demonstrated morphometrically increased between 2 and 12 weeks. Intimal thickening in vein grafts is due to SMC proliferation and develops after the EC layer has been restored. In contrast, intimal SMC proliferate in damaged arteries when the EC layer is absent and cease when the EC layer is regenerated

  20. Sliding Window-Based Region of Interest Extraction for Finger Vein Images

    Science.gov (United States)

    Yang, Lu; Yang, Gongping; Yin, Yilong; Xiao, Rongyang

    2013-01-01

    Region of Interest (ROI) extraction is a crucial step in an automatic finger vein recognition system. The aim of ROI extraction is to decide which part of the image is suitable for finger vein feature extraction. This paper proposes a finger vein ROI extraction method which is robust to finger displacement and rotation. First, we determine the middle line of the finger, which will be used to correct the image skew. Then, a sliding window is used to detect the phalangeal joints and further to ascertain the height of ROI. Last, for the corrective image with certain height, we will obtain the ROI by using the internal tangents of finger edges as the left and right boundary. The experimental results show that the proposed method can extract ROI more accurately and effectively compared with other methods, and thus improve the performance of finger vein identification system. Besides, to acquire the high quality finger vein image during the capture process, we propose eight criteria for finger vein capture from different aspects and these criteria should be helpful to some extent for finger vein capture. PMID:23507824

  1. Surgical Access to Jejunal Veins for Local Thrombolysis and Stent Placement in Portal Vein Thrombosis

    International Nuclear Information System (INIS)

    Schellhammer, Frank; Esch, Jan Schulte am; Hammerschlag, Sascha; Knoefel, Wolfram Trudo; Fuerst, Guenter

    2008-01-01

    Portal vein thrombosis is an infrequent entity, which may cause high morbidity and mortality. We report a case of portal vein thrombosis due to benign stenosis following partial pancreatoduodenectomy with segmental replacement of the portal vein by a Gore-tex graft. Using a surgical access to jenunal veins, local thrombolysis, mechanical fragmentation of thrombus, and stent placement were successfully performed.

  2. Preoperative mapping of the saphenous vein

    DEFF Research Database (Denmark)

    Levi-Mazloum, Niels Donald; Sillesen, H; Nielsen, Tina G

    1995-01-01

    A consecutive series of 92 patients had their greater saphenous vein assessed with duplex ultrasound scanning prior to planned infrainguinal bypass procedures. A naturally occurring optimal vein diameter was discovered. It was significantly correlated with higher postoperative ankle-brachial pres......-brachial pressure index (ABI) and lesser early postoperative thrombosis. A significant linear regression was found between the pre and postoperative vein diameter....

  3. Speech Recognition

    Directory of Open Access Journals (Sweden)

    Adrian Morariu

    2009-01-01

    Full Text Available This paper presents a method of speech recognition by pattern recognition techniques. Learning consists in determining the unique characteristics of a word (cepstral coefficients by eliminating those characteristics that are different from one word to another. For learning and recognition, the system will build a dictionary of words by determining the characteristics of each word to be used in the recognition. Determining the characteristics of an audio signal consists in the following steps: noise removal, sampling it, applying Hamming window, switching to frequency domain through Fourier transform, calculating the magnitude spectrum, filtering data, determining cepstral coefficients.

  4. Collateral veins in inferior caval vein occlusion demonstrated via CT

    International Nuclear Information System (INIS)

    Lien, H.H.; Lund, G.

    1983-01-01

    CT-scans of 12 patients with tumour-induced occlusion of the inferior vena cava were studied with regard to collateral veins. A comparison was performed with findings at phlebography in 10 patients and at autopsy in 2. The site and appearance of the main collateral pathway are presented. A close study of vascular structures renders useful information on collateral circulation in occlusion of the inferior vena cava. (orig.)

  5. Recurrence of superficial vein thrombosis in patients with varicose veins.

    Science.gov (United States)

    Karathanos, Christos; Spanos, Konstantinos; Saleptsis, Vassileios; Tsezou, Aspasia; Kyriakou, Despina; Giannoukas, Athanasios D

    2016-08-01

    To investigate which factors other than history of superficial vein thrombosis (SVT) are associated with recurrent spontaneous SVT episodes in patients with varicose veins (VVs). Patients with a history of spontaneous SVT and VVs were followed up for a mean period of 55 months. Demographics, comorbidities, and thrombophilia screening test were analyzed. Patients were grouped according to the clinical-etiology-anatomy-pathophysiology classification. A multiple logistic regression analysis with the forward likelihood ratio method was undertaken. Thirteen patients out of 97 had a recurrence SVT episode during the follow-up period. All those patients were identified to have a thrombophilia defect. Protein C and S, antithrombin, and plasminogen deficiencies were more frequently present in patients without recurrence. Gene mutations were present in 38% in the nonrecurrence group and 77% in the recurrence group. After logistic regression analysis, patients with dislipidemia and mutation in prothrombin G20210A (FII) had an increased risk for recurrence by 5.4-fold and 4.6-fold, respectively. No deep vein thrombosis or pulmonary embolism occurred. Dislipidemia and gene mutations of F II are associated with SVT recurrence in patients with VVs. A selection of patients may benefit from anticoagulation in the short term and from VVs intervention in the long term. © The Author(s) 2015.

  6. Using lock-in infrared thermography for the visualization of the hand vascular tree

    Science.gov (United States)

    Bouzida, Nabila; Bendada, Abdel Hakim; Piau, Jean-Marc; Akhloufi, Moulay; Maldague, Xavier; Raymond, Mathieu

    2008-03-01

    An imaging technique of the hand vein tree is presented in this paper. Using the natural human circulatory system and a controlled armband pressure around the arm, a lock-in thermography technique with an internal excitation is carried out. Since the stimulation frequency is inversely proportional to the inspection depth, the subcutaneous layer requires the use of a very slow frequency. Thus, a sawtooth waveform is preferred to minimize the duration of the pressure applied to the armband during the experiment. A frequency of approximately 0.03 Hz and a pressure range between 100 and 140 mmHg, according to the diastolic and systolic blood pressure, are used as stimulation. Then, dorsal hand amplitude and phase images are obtained with IR_view (Klein, 1999), a tool specifically designed to analyze infrared images. The hand vein structure is thermally mapped by an infrared camera operating in the middle wavelength infrared range (MWIR) at room temperature. Parasitic frequencies are avoided by keeping the hand fixed. The resulting images show a gradient of temperature between surrounding tissues and the back-of-hand veins. The vascular signature segmentation is extracted from the amplitude and phase images by using a Fast Fourier Transform image processing technique. This work could be used for vein localization for perfusion or for the early diagnosis of vein diseases such as primitive varicose and deep vein thrombosis (DVT). A hand vein signature database for identification purposes is also possible.

  7. Improving the Outcome of Vein Grafts: Should Vascular Surgeons Turn Veins into Arteries?

    OpenAIRE

    Isaji, Toshihiko; Hashimoto, Takuya; Yamamoto, Kota; Santana, Jeans M.; Yatsula, Bogdan; Hu, Haidi; Bai, Hualong; Jianming, Guo; Kudze, Tambudzai; Nishibe, Toshiya; Dardik, Alan

    2017-01-01

    Autogenous vein grafts remain the gold standard conduit for arterial bypass, particularly for the treatment of critical limb ischemia. Vein graft adaptation to the arterial environment, i.e., adequate dilation and wall thickening, contributes to the superior performance of vein grafts. However, abnormal venous wall remodeling with excessive neointimal hyperplasia commonly causes vein graft failure. Since the PREVENT trials failed to improve vein graft outcomes, new strategies focus on the ada...

  8. Blood sampling from adrenal gland vein

    International Nuclear Information System (INIS)

    Sun Yong; Ni Caifang

    2009-01-01

    Adrenal gland vein sampling is an interventional method to get the blood samples from the adrenal gland vein. The blood is obtained via a catheter which is selectively inserted in the adrenal gland vein. This technique is mainly used to be diagnostic for primary hyperaldosteronism. A full knowledge of the anatomy and variations of the adrenal gland vein, serious preoperative preparation and skilled catheterization manipulation are necessary for obtaining sufficient blood sample and for reducing the occurrence of complications. Providing the physicians with definite diagnostic evidence and being technically feasible, adrenal gland vein sampling should become one of the routine examinations for clarifying the cause of primary hyperaldosteronism. (authors)

  9. Unusual termination of the right testicular vein | Woldeyes | Anatomy ...

    African Journals Online (AJOL)

    The testicular veins are formed by the veins emerging from the testis and epididymis forming the pampiniform venous plexus. The right testicular vein drains into inferior vena cava and the left testicular vein to the left renal vein. Testicular veins display a great variability with regard to their number, course and sites of ...

  10. The angiographic demonstration of hepatic vein obstruction

    International Nuclear Information System (INIS)

    Zu Maoheng; Xu Hao; Li Guojun; Gu Yuming; Wei Ning; Wang Cheng; Xu Wei

    2004-01-01

    Objective: To evaluate the angiographic feature of hepatic vein obstruction. Methods Forty-five patients (male 23, female 22, age 9-54 years) suffered from hepatic vein obstruction. The inferior vena cavography and the hepatic venography were performed in all cases. Results: IVC was free in 37 patients with hepatic vein obstruction, both IVC and HV were obstructed in 8 patients. The local or long stenosis of IVC was found in 31 inferior vena cavography. The diameter of IVC was normal in 12 patients. The sign of membranous dome was found in hepatic vein orifice in 5 cases and in accessory hepatic vein orifice in 4 cases. Intrahepatic venous collaterals were found in 45 cases. Conclusion: Hepatic vein obstruction can be reproached primarily in inferior vena cavography, the membranous dome is a direct sign of membranous obstruction of HV and AHV in inferior vena cavography. The selected hepatic venography can provide reliable evidence to diagnose hepatic vein obstruction

  11. Vein-type uranium deposits

    International Nuclear Information System (INIS)

    Rich, R.A.; Holland, H.D.; Petersen, U.

    1975-01-01

    A critical review is presented of published data bearing on the mineralogy, paragenesis, geochemistry, and origin of veiw-type uranium deposits. Its aim is to serve as a starting point for new research and as a basis for the development of new exploration strategies. During the formation of both vein and sandstone types of deposits uranium seems to have been dissolved by and transported in rather oxidized solutions, and deposited where these solutions encountered reducing agents such as carbon, sulfides, ferrous minerals and hydrocarbons. Granitic rocks abnormally enriched in uranium have apparently been the most common source for uranium in vein-type deposits. Oxidizing solutions have been derived either from the surface or from depth. Surface solutions saturated with atmospheric oxygen have frequently passed through red bed or clean sandstone conduits on their way to and from uranium source rocks. Deep solutions of non-surface origin have apparently become sufficiently oxidizing by passage through and equilibration with red beds. The common association of clean sandstones or red beds with uranium-rich granites in the vicinity of vein-type uranium deposits is probably not fortuitous, and areas where these rock types are found together are considered particularly favorable targets for uranium exploration

  12. Volume correction in the aging hand: role of dermal fillers

    Directory of Open Access Journals (Sweden)

    Rivkin AZ

    2016-08-01

    Full Text Available Alexander Z Rivkin David Geffen/UCLA School of Medicine Los Angeles, CA, USA Abstract: The hands, just like the face, are highly visible parts of the body. They age at a similar rate and demonstrate comparable changes with time, sun damage, and smoking. Loss of volume in the hands exposes underlying tendons, veins, and bony prominences. Rejuvenation of the hands with dermal fillers is a procedure with high patient satisfaction and relatively low risk for complications. This study will review relevant anatomy, injection technique, clinical safety, and efficacy of dermal filler volumization of the aging hand. Keywords: dermal fillers, hands, volumization, hyaluronic acid, calcium hydroxylapatite

  13. Online handwritten mathematical expression recognition

    Science.gov (United States)

    Büyükbayrak, Hakan; Yanikoglu, Berrin; Erçil, Aytül

    2007-01-01

    We describe a system for recognizing online, handwritten mathematical expressions. The system is designed with a user-interface for writing scientific articles, supporting the recognition of basic mathematical expressions as well as integrals, summations, matrices etc. A feed-forward neural network recognizes symbols which are assumed to be single-stroke and a recursive algorithm parses the expression by combining neural network output and the structure of the expression. Preliminary results show that writer-dependent recognition rates are very high (99.8%) while writer-independent symbol recognition rates are lower (75%). The interface associated with the proposed system integrates the built-in recognition capabilities of the Microsoft's Tablet PC API for recognizing textual input and supports conversion of hand-drawn figures into PNG format. This enables the user to enter text, mathematics and draw figures in a single interface. After recognition, all output is combined into one LATEX code and compiled into a PDF file.

  14. Admittance Control for Robot Assisted Retinal Vein Micro-Cannulation under Human-Robot Collaborative Mode

    Science.gov (United States)

    Gonenc, Berk; Iordachita, Iulian

    2017-01-01

    Retinal vein occlusion is one of the most common retinovascular diseases. Retinal vein cannulation is a potentially effective treatment method for this condition that currently lies, however, at the limits of human capabilities. In this work, the aim is to use robotic systems and advanced instrumentation to alleviate these challenges, and assist the procedure via a human-robot collaborative mode based on our earlier work on the Steady-Hand Eye Robot and force-sensing instruments. An admittance control method is employed to stabilize the cannula relative to the vein and maintain it inside the lumen during the injection process. A pre-stress strategy is used to prevent the tip of microneedle from getting out of vein in in prolonged infusions, and the performance is verified through simulations. PMID:29607442

  15. Admittance Control for Robot Assisted Retinal Vein Micro-Cannulation under Human-Robot Collaborative Mode.

    Science.gov (United States)

    Zhang, He; Gonenc, Berk; Iordachita, Iulian

    2017-10-01

    Retinal vein occlusion is one of the most common retinovascular diseases. Retinal vein cannulation is a potentially effective treatment method for this condition that currently lies, however, at the limits of human capabilities. In this work, the aim is to use robotic systems and advanced instrumentation to alleviate these challenges, and assist the procedure via a human-robot collaborative mode based on our earlier work on the Steady-Hand Eye Robot and force-sensing instruments. An admittance control method is employed to stabilize the cannula relative to the vein and maintain it inside the lumen during the injection process. A pre-stress strategy is used to prevent the tip of microneedle from getting out of vein in in prolonged infusions, and the performance is verified through simulations.

  16. Design and implementation of a contactless multiple hand feature acquisition system

    Science.gov (United States)

    Zhao, Qiushi; Bu, Wei; Wu, Xiangqian; Zhang, David

    2012-06-01

    In this work, an integrated contactless multiple hand feature acquisition system is designed. The system can capture palmprint, palm vein, and palm dorsal vein images simultaneously. Moreover, the images are captured in a contactless manner, that is, users need not to touch any part of the device when capturing. Palmprint is imaged under visible illumination while palm vein and palm dorsal vein are imaged under near infrared (NIR) illumination. The capturing is controlled by computer and the whole process is less than 1 second, which is sufficient for online biometric systems. Based on this device, this paper also implements a contactless hand-based multimodal biometric system. Palmprint, palm vein, palm dorsal vein, finger vein, and hand geometry features are extracted from the captured images. After similarity measure, the matching scores are fused using weighted sum fusion rule. Experimental results show that although the verification accuracy of each uni-modality is not as high as that of state-of-the-art, the fusion result is superior to most of the existing hand-based biometric systems. This result indicates that the proposed device is competent in the application of contactless multimodal hand-based biometrics.

  17. The umbilical and paraumbilical veins of man.

    Science.gov (United States)

    Martin, B F; Tudor, R G

    1980-03-01

    During its transit through the umbilicus structural changes occur in the thick wall of the extra-abdominal segment of the umbilical vein whereby the components of the intra-abdominal segment acquire an essentially longitudinal direction and become arranged in fibro-elastic and fibro-muscular zones. The vein lumen becomes largely obliterated by asymmetrical proliferation of loose subendothelial conective tissue. The latter forms a new inner zone within which a small segment of the lumen persists in an eccentric position. This residual lumen transmits blood to the portal system from paraumbilical and systemic sources, and is retained in the upper part of the vein, even in old age. A similar process of lumen closure is observed in the ductus venosus. In early childhood the lower third of the vein undergoes breakdown, with fatty infiltration, resulting in its complete division into vascular fibro-elastic strands, and in old age some breakdown occurs in the outermost part of the wall of the upper two thirds. The paraumbilical veins are thick-walled and of similar structure to the umbilical vein. Together they constitute an accessory portal system which is confined between the layers of the falciform ligament and is in communication with the veins of the ventral abdominal wall. The constituents form an ascending series, namely, Burow's veins, the umbilical vein, and Sappey's inferior and superior veins. The main channel of Sappey's inferior veins may be the remnant of the right umbilical vein since it communicates with the right rectus sheath and often communicates directly with the portal system within the right lobe of the liver. The results are of significance in relation to clinical usage of the umbilical vein.

  18. Compartment Syndrome following Open Femoral Fracture with an Isolated Femoral Vein Injury Treated with Acute Repair

    Directory of Open Access Journals (Sweden)

    David Walmsley

    2014-01-01

    Full Text Available Acute compartment syndrome is a surgical emergency and its diagnosis is more difficult in obtunded or insensate patients. We present the case of a 34-year-old woman who sustained a Gustilo-Anderson grade III open midshaft femur fracture with an isolated femoral vein injury treated with direct repair. She developed lower leg compartment syndrome at 48 hours postoperatively, necessitating fasciotomies. She was subsequently found to have a DVT in her femoral vein at the level of the repair and was started on therapeutic anticoagulation. This case highlights the importance of recognition of isolated venous injuries in a trauma setting as a risk factor for developing compartment syndrome.

  19. A systematic review of the etiopathogenesis of Kienböck's disease and a critical appraisal of its recognition as an occupational disease related to hand-arm vibration

    Directory of Open Access Journals (Sweden)

    Stahl Stéphane

    2012-11-01

    Full Text Available Abstract Background We systematically reviewed etiological factors of Kienböck’s disease (osteonecrosis of the lunate discussed in the literature in order to examine the justification for including Kienböck’s disease (KD in the European Listing of Occupational Diseases. Methods We searched the Ovid/Medline and the Cochrane Library for articles discussing the etiology of osteonecrosis of the lunate published since the first description of KD in 1910 and up until July 2012 in English, French or German. Literature was classified by the level of evidence presented, the etiopathological hypothesis discussed, and the author's conclusion about the role of the etiopathological hypothesis. The causal relationship between KD and hand-arm vibration was elucidated by the Bradford Hill criteria. Results A total of 220 references was found. Of the included 152 articles, 140 (92% reached the evidence level IV (case series. The four most frequently discussed factors were negative ulnar variance (n=72; 47%, primary arterial ischemia of the lunate (n=63; 41%, trauma (n=63; 41% and hand-arm vibration (n=53; 35%. The quality of the cohort studies on hand-arm vibration did not permit a meta-analysis to evaluate the strength of an association to KD. Evidence for the lack of consistency, plausibility and coherence of the 4 most frequently discussed etiopathologies was found. No evidence was found to support any of the nine Bradford Hill criteria for a causal relationship between KD and hand-arm vibration. Conclusions A systematic review of 220 articles on the etiopathology of KD and the application of the Bradford Hill criteria does not provide sufficient scientific evidence to confirm or refute a causal relationship between KD and hand-arm vibration. This currently suggests that, KD does not comply with the criteria of the International Labour Organization determining occupational diseases. However, research with a higher level of evidence is required to

  20. Hand Grasping Synergies As Biometrics.

    Science.gov (United States)

    Patel, Vrajeshri; Thukral, Poojita; Burns, Martin K; Florescu, Ionut; Chandramouli, Rajarathnam; Vinjamuri, Ramana

    2017-01-01

    Recently, the need for more secure identity verification systems has driven researchers to explore other sources of biometrics. This includes iris patterns, palm print, hand geometry, facial recognition, and movement patterns (hand motion, gait, and eye movements). Identity verification systems may benefit from the complexity of human movement that integrates multiple levels of control (neural, muscular, and kinematic). Using principal component analysis, we extracted spatiotemporal hand synergies (movement synergies) from an object grasping dataset to explore their use as a potential biometric. These movement synergies are in the form of joint angular velocity profiles of 10 joints. We explored the effect of joint type, digit, number of objects, and grasp type. In its best configuration, movement synergies achieved an equal error rate of 8.19%. While movement synergies can be integrated into an identity verification system with motion capture ability, we also explored a camera-ready version of hand synergies-postural synergies. In this proof of concept system, postural synergies performed well, but only when specific postures were chosen. Based on these results, hand synergies show promise as a potential biometric that can be combined with other hand-based biometrics for improved security.

  1. Hand Grasping Synergies As Biometrics

    Directory of Open Access Journals (Sweden)

    Ramana Vinjamuri

    2017-05-01

    Full Text Available Recently, the need for more secure identity verification systems has driven researchers to explore other sources of biometrics. This includes iris patterns, palm print, hand geometry, facial recognition, and movement patterns (hand motion, gait, and eye movements. Identity verification systems may benefit from the complexity of human movement that integrates multiple levels of control (neural, muscular, and kinematic. Using principal component analysis, we extracted spatiotemporal hand synergies (movement synergies from an object grasping dataset to explore their use as a potential biometric. These movement synergies are in the form of joint angular velocity profiles of 10 joints. We explored the effect of joint type, digit, number of objects, and grasp type. In its best configuration, movement synergies achieved an equal error rate of 8.19%. While movement synergies can be integrated into an identity verification system with motion capture ability, we also explored a camera-ready version of hand synergies—postural synergies. In this proof of concept system, postural synergies performed well, but only when specific postures were chosen. Based on these results, hand synergies show promise as a potential biometric that can be combined with other hand-based biometrics for improved security.

  2. A Morphological Insight of the Femoral Vein

    Directory of Open Access Journals (Sweden)

    Ferreira AH

    2015-10-01

    Full Text Available A total of 13 cadavers (12 men and 1 women of different age group were used for the study with the purpose to determine the prevalence of femoral vein duplication. Lower limb regions (26 sides were carefully dissected as per the standard dissection procedure. Femoral vein (unitruncular was found in 96.15% of specimen. Bitruncular configurations (total bifidity was found in a male cadaver of 75 years of age (3.85%. In the right lower limb, 6.5 cms below the inguinal ligament the femoral vein - lateral ramus received the lateral circumflex femoral vein, and the medial circumflex femoral vein, and the lateral and medial ramii formed a common venous trunk. Knowledge of the truncular venous variations is important to recognize and avoid potential errors in diagnosis of deep venous thrombosis of the femoral vein, in the case of an occluded duplicated trunk.

  3. Normal hepatic vein patterns on ultrasound

    International Nuclear Information System (INIS)

    Kim, Hae Jin; Chae, Yoo Soon; Park, Hea Yeoung; Park, Bok Hwan; Kim, Yang Sook

    1987-01-01

    Understanding of the anatomy of the hepatic vein is important in manipulation for transplantation of the liver, hepatectomy and the treatment of hepatic trauma with avulsion of the hepatic vein. Demonstrated of the inferior right hepatic vein (IRHV) is also important; in some cases of hepatocellular carcinoma, thrombus can be seen in the IRHV; in primary Budd-Chiari syndrome, the IRHV is main draining vein; during hepatectomy, the postero-inferior segment of the right lobe and draining IRHV can be preserved. For some 10 months ultrasound examination was done in a total of 124 patients with normal liver function with special emphasis on the hepatic vein, their branches, and the IRHV, and analysed in terms of branching pattern and relative size of the hepatic vein and the detection rate of the IRHV.

  4. Generating and analyzing synthetic finger vein images

    OpenAIRE

    Hillerström, Fieke; Kumar, Ajay; Veldhuis, Raymond N.J.

    2014-01-01

    Abstract: The finger-vein biometric offers higher degree of security, personal privacy and strong anti-spoofing capabilities than most other biometric modalities employed today. Emerging privacy concerns with the database acquisition and lack of availability of large scale finger-vein database have posed challenges in exploring this technology for large scale applications. This paper details the first such attempt to synthesize finger-vein images and presents analysis of synthesized images fo...

  5. Clean Hands Count

    Medline Plus

    Full Text Available ... has been rented. This feature is not available right now. Please try again later. Published on May ... 34 How The Clean Hands - Safe Hands System Works - Duration: 3:38. Clean Hands-Safe Hands 5, ...

  6. SURVEY OF BIOMETRIC SYSTEMS USING IRIS RECOGNITION

    OpenAIRE

    S.PON SANGEETHA; DR.M.KARNAN

    2014-01-01

    The security plays an important role in any type of organization in today’s life. Iris recognition is one of the leading automatic biometric systems in the area of security which is used to identify the individual person. Biometric systems include fingerprints, facial features, voice recognition, hand geometry, handwriting, the eye retina and the most secured one presented in this paper, the iris recognition. Biometric systems has become very famous in security systems because it is not possi...

  7. Fabrication of subcutaneous veins phantom for vessel visualization system

    Science.gov (United States)

    Cheng, Kai; Narita, Kazuyuki; Morita, Yusuke; Nakamachi, Eiji; Honda, Norihiro; Awazu, Kunio

    2013-09-01

    The technique of subcutaneous veins imaging by using NIR (Near Infrared Radiation) is widely used in medical applications, such as the intravenous injection and the blood sampling. In the previous study, an automatic 3D blood vessel search and automatic blood sampling system was newly developed. In order to validate this NIR imaging system, we adopted the subcutaneous vein in the human arm and its artificial phantom, which imitate the human fat and blood vessel. The human skin and subcutaneous vein is characterized as the uncertainty object, which has the individual specificity, non-accurate depth information, non-steady state and hardly to be fixed in the examination apparatus. On the other hand, the conventional phantom was quite distinct from the human's characteristics, such as the non-multilayer structure, disagreement of optical property. In this study, we develop a multilayer phantom, which is quite similar with human skin, for improvement of NIR detection system evaluation. The phantom consists of three layers, such as the epidermis layer, the dermis layer and the subcutaneous fat layer. In subcutaneous fat layer, we built a blood vessel. We use the intralipid to imitate the optical scattering characteristics of human skin, and the hemoglobin and melanin for the optical absorption characteristics. In this study, we did two subjects. First, we decide the fabrication process of the phantom. Second, we compared newly developed phantoms with human skin by using our NIR detecting system, and confirm the availability of these phantoms.

  8. Blood vessel classification into arteries and veins in retinal images

    Science.gov (United States)

    Kondermann, Claudia; Kondermann, Daniel; Yan, Michelle

    2007-03-01

    The prevalence of diabetes is expected to increase dramatically in coming years; already today it accounts for a major proportion of the health care budget in many countries. Diabetic Retinopathy (DR), a micro vascular complication very often seen in diabetes patients, is the most common cause of visual loss in working age population of developed countries today. Since the possibility of slowing or even stopping the progress of this disease depends on the early detection of DR, an automatic analysis of fundus images would be of great help to the ophthalmologist due to the small size of the symptoms and the large number of patients. An important symptom for DR are abnormally wide veins leading to an unusually low ratio of the average diameter of arteries to veins (AVR). There are also other diseases like high blood pressure or diseases of the pancreas with one symptom being an abnormal AVR value. To determine it, a classification of vessels as arteries or veins is indispensable. As to our knowledge despite the importance there have only been two approaches to vessel classification yet. Therefore we propose an improved method. We compare two feature extraction methods and two classification methods based on support vector machines and neural networks. Given a hand-segmentation of vessels our approach achieves 95.32% correctly classified vessel pixels. This value decreases by 10% on average, if the result of a segmentation algorithm is used as basis for the classification.

  9. Normal distal pulmonary vein anatomy

    Directory of Open Access Journals (Sweden)

    Wiesława Klimek-Piotrowska

    2016-01-01

    Full Text Available Background. It is well known that the pulmonary veins (PVs, especially their myocardial sleeves play a critical role in the initiation and maintenance of atrial fibrillation. Understanding the PV anatomy is crucial for the safety and efficacy of all procedures performed on PVs. The aim of this study was to present normal distal PV anatomy and to create a juxtaposition of all PV ostium variants.Methods. A total of 130 randomly selected autopsied adult human hearts (Caucasian were examined. The number of PVs ostia was evaluated and their diameter was measured. The ostium-to-last-tributary distance and macroscopic presence of myocardial sleeves were also evaluated.Results. Five hundred forty-one PV ostia were identified. Four classical PV ostia patterns (two left and two right PVs were observed in 70.8% of all cases. The most common variant was the classical pattern with additional middle right PV (19.2%, followed by the common ostium for the left superior and the inferior PVs (4.44%. Mean diameters of PV ostia (for the classical pattern were: left superior = 13.8 ± 2.9 mm; left inferior = 13.3 ± 3.4 mm; right superior = 14.3 ± 2.9 mm; right inferior = 13.7 ± 3.3 mm. When present, the additional middle right PV ostium had the smallest PV ostium diameter in the heart (8.2 ± 4.1 mm. The mean ostium-to-last-tributary (closest to the atrium distances were: left superior = 15.1 ± 4.6 mm; left inferior = 13.5 ± 4.0 mm; right superior = 11.8 ± 4.0 mm; right inferior = 11.0 ± 3.7 mm. There were no statistically significant differences between sexes in ostia diameters and ostium-to-last-tributary distances.Conclusion. Only 71% of the cases have four standard pulmonary veins. The middle right pulmonary vein is present in almost 20% of patients. Presented data can provide useful information for the clinicians during interventional procedures or radiologic examinations of PVs.

  10. Large vein injection alleviates rocuronium-induced pain in gynaecologic patients.

    Science.gov (United States)

    Zhang, Xing-Mei; Wang, Qun; Wang, Wei-Si; Wang, Meng

    2017-08-01

    Rocuronium-induced pain upon injection is very common in the clinical setting. Using the antecubital rather than the hand vein can avoid pain due to propofol injection. We aimed to investigate whether the use of the antecubital vein for injection would alleviate rocuronium-induced pain in a similar fashion. Sixty patients (ASA classes I and II) scheduled for gynaecologic laparoscopy were randomised into two groups. Rocuronium (0.6mg/kg) was injected either into the vein on the dorsum of the hand (group D) or a large vein in the antecubital fossa (group A). Pain was assessed and recorded using a four-point scale. Compared with group D, the incidence of pain and severe pain was lower in group A patients. The rate of no pain was also higher in group A patients. The incidence and severity of rocuronium-induced injection pain were significantly alleviated via use of a large vein for rocuronium injection. Copyright © 2016 Société française d'anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.

  11. Interventional treatment of iliac vein compression syndrome

    International Nuclear Information System (INIS)

    Li Xiaoqiang; Zhou Weiming; Nie Zhonglin; Yu Chaowen

    2002-01-01

    Objective: To explore the clinical significance of interventional treatment of iliac vein compression syndrome (IVCS). Methods: Percutaneous transluminal angioplasty (PTA) was performed in 40 cases. Thirty-three cases underwent endovascular stent implantation and 27 cases underwent second-stage left saphenous vein ligation and stripping and the valves of left femoral veins narrowing. Thirty-one cases were followed-up postoperatively and the duration was 6-66 months (mean 28 months). Results: The dilation of iliac veins was successful in 36 cases and there were god efficacy in all patients when they discharged from hospital. Followed-up during post-operation, all the limbs ulcers were cured and varicose veins disappeared. The skin pigmentation disappeared in 17 of 19 cases and markedly relieved in 2 cases. Left lower limb swelling disappeared in 15 of 17 cases and relieved in 2 cases. Conclusion: There is good efficacy in the interventional treatment of left iliac vein lesions, but second-stage procedures should be performed in secondary lesions of saphenous veins and valves of femoral veins

  12. Retinal vein occlusion: pathophysiology and treatment options

    OpenAIRE

    Karia, Niral

    2010-01-01

    Niral KariaDepartment of Ophthalmology, Southend Hospital, Prittlewell Chase, Westcliff on Sea, Essex, United KingdomAbstract: This paper reviews the current thinking about retinal vein occlusion. It gives an overview of its pathophysiology and discusses the evidence behind the various established and emerging treatment paradigms.Keywords: central, hemispheric, branch, retinal vein occlusion, visual loss

  13. Generating and analyzing synthetic finger vein images

    NARCIS (Netherlands)

    Hillerström, Fieke; Kumar, Ajay; Veldhuis, Raymond N.J.

    2014-01-01

    Abstract: The finger-vein biometric offers higher degree of security, personal privacy and strong anti-spoofing capabilities than most other biometric modalities employed today. Emerging privacy concerns with the database acquisition and lack of availability of large scale finger-vein database have

  14. Preoperative mapping of the saphenous vein

    DEFF Research Database (Denmark)

    Levi-Mazloum, Niels Donald; Sillesen, H; Nielsen, Tina G

    1996-01-01

    A series of 124 patients had their greater saphenous vein assessed with duplex ultrasound scanning prior to planned infrainguinal bypass procedures. 33 (27%) bypass procedures thrombosed within the first year. A naturally occurring optimal vein diameter was discovered: 5.0-6.5 mm at mid-thigh lev...

  15. The veining phenomenon in unalloyed plutonium

    International Nuclear Information System (INIS)

    White, J.S.

    1976-01-01

    An investigation has been made of the veining phenomenon in unalloyed plutonium. The surface markings, or veins, which are sometimes seen on α-phase plutonium samples, arise as a result of the β→α transformation. As far as is known, this veining is unrivalled in its scale and form as compared with the solid state surface transformation effects shown by any other metal. The phenomenon has been explained by the application of the Le Chatelier principle to the phase change. In this instance, the large (10%) volume contraction associated with the β→α reaction and the anisotropy of the nonoclinic α-phase structure, account for the fact that the veins are so prominent in plutonium. On the basis of the proposed model, the veins can only form at temperatures where the transformation mechanism is non-martensitic. (Auth.)

  16. Ultrasound assessment of great saphenous vein insufficiency

    Directory of Open Access Journals (Sweden)

    Chander RK

    2015-06-01

    Full Text Available Rajiv K Chander,1 Thomas S Monahan1,2 1Section of Vascular Surgery, Department of Surgery, University of Maryland School of Medicine, 2Department of Surgery, Baltimore Veterans Affairs Medical Center, Baltimore, MD, USA Abstract: Duplex ultrasonography is the ideal modality to assess great saphenous vein insufficiency. Duplex ultrasonography incorporates both gray scale images to delineate anatomy and color-Doppler imaging that visualizes the flow of blood in a structure. Assessment of great saphenous vein requires definition of the anatomy, augmentation of flow, evaluation for both superficial and deep vein thrombosis, and determining the presence of reflux. Currently, evolution in the treatment of reflux also relies on ultrasound for the treatment of the disease. Understanding the utilization of the ultrasound for the diagnosis and treatment of greater saphenous vein reflux is important for practitioners treating reflux disease. Keywords: duplex ultrasonography, small saphenous vein 

  17. Cavernous transformation of the portal vein

    International Nuclear Information System (INIS)

    Lehotska, V.; Dostalova, K.; Durkovsky, A.; Samal, V.

    1995-01-01

    In this contribution, the authors give an account of a rare case of a cavernous transformation of the portal vein that may have originated secondarily in a proliferative hematogenous disease with a polyglobulia and thrombosis in the periferal blood count as well as development of portal hypertension of a prehepatal type. The state of hyper-coagulation in a myeloproliferative disease may have lead to a chronic thrombosis of the portal vein with a subsequent malformation of the portal vein in terms of a cavernous transformation of the portal vein. The case is an interesting one because of the discrepancy between the gravity of the thrombotic complication and slightness of the symptoms in the clinical picture. The authors point out the importance of ultrasonography and computed tomography examination following the intravenous application of a water solution of a contrast medium in a morphologic diagnosing of a rare complication of a chronic thrombotic clot of the portal vein - the cavernous transformation. (authors)

  18. Assessment and management of patients with varicose veins.

    Science.gov (United States)

    Allen, Louise

    Varicose veins are enlarged superficial veins found in the legs. This article explores the anatomy and physiology of the venous system to assist nurses to assess, manage and treat patients with varicose veins.

  19. Speaker Recognition

    DEFF Research Database (Denmark)

    Mølgaard, Lasse Lohilahti; Jørgensen, Kasper Winther

    2005-01-01

    Speaker recognition is basically divided into speaker identification and speaker verification. Verification is the task of automatically determining if a person really is the person he or she claims to be. This technology can be used as a biometric feature for verifying the identity of a person...

  20. Idiopathic Bilateral External Jugular Vein Thrombosis.

    Science.gov (United States)

    Hindi, Zakaria; Fadhel, Ehab

    2015-08-20

    Vein thrombosis is mainly determined by 3 factors, which constitute a triad called Virchow's triad: hypercoagulability, stasis, and endothelial injury. Venous thrombosis commonly occurs in the lower extremities since most of the blood resides there and flows against gravity. The veins of the lower extremities are dependent on intact valves and fully functional leg muscles. However, in case of valvular incompetency or muscular weakness, thrombosis and blood stasis will occur as a result. In contrast, the veins of the neck, specially the jugulars, have distensible walls which allow flexibility during respiration. In addition, the blood directly flows downward towards the heart. Nevertheless, many case reports mentioned the thrombosis of internal jugular veins and external jugular veins with identified risk factors. Jugular vein thrombosis has previously been associated in the literature with a variety of medical conditions, including malignancy. This report is of a case of idiopathic bilateral external jugular vein thrombosis in a 21 year-old male construction worker of Southeast Asian origin with no previous medical history who presented with bilateral facial puffiness of gradual onset over 1 month. Doppler ultrasound and computed tomography were used in the diagnosis. Further work-up showed no evidence of infection or neoplasia. The patient was eventually discharged on warfarin. The patient was assessed after 6 months and his symptoms had resolved completely. Bilateral idiopathic external jugular veins thrombosis is extremely rare and can be an indicator of early malignancy or hidden infection. While previous reports in the literature have associated jugular vein thrombosis with malignancy, the present case shows that external jugular vein thrombosis can also be found in persons without malignancy.

  1. Handwriting Moroccan regions recognition using Tifinagh character

    Directory of Open Access Journals (Sweden)

    B. El Kessab

    2015-09-01

    In this context we propose a data set for handwritten Tifinagh regions composed of 1600 image (100 Image for each region. The dataset can be used in one hand to test the efficiency of the Tifinagh region recognition system in extraction of characteristics significatives and the correct identification of each region in classification phase in the other hand.

  2. Hand Surgery: Anesthesia

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is a Hand Surgeon? What is a Hand Therapist? Media Find a Hand Surgeon Home Anatomy Hand Surgery Anesthesia Email to a friend * required ...

  3. Retro-aortic left renal vein--an anatomic variation description and review of literature.

    Science.gov (United States)

    Suma, H Yekappa; Roopa, Kulkarni

    2011-01-01

    This study reports the presence of a retro-aortic renal vein on the left side draining into the inferior vena cava. This variation was observed during routine dissection in a female cadaver aged about 55 years. This variation is of importance because of its implications in renal transplantation, renal surgery, vascular surgery, uroradiology and gonadal surgeries. The knowledge of such variations can help the clinicians for its recognition and protection.

  4. Duplex sonography of the near-surface leg veins

    International Nuclear Information System (INIS)

    Mendoza, E.

    2007-01-01

    The book contains the following contributions: The ultrasonograph, selection of the ultrasonic transducer, anatomy of the near-surface vein system, physiology of the near-surface vein system, varicose status classification, systematics of the duplex sonography of near-surface leg veins, provocational maneuver for the duplex sonographic varicose diagnostics, exploration of vena saphena parva, perforans veins, side branches, phlebitis, sonography for varicose therapy, postsurgical sonography, deep leg veins, examination of near-surface leg veins for the pathology of the deep vein system, differential diagnostic clarification of leg oedema from the phlebologic-lymphological view, diagnostic side features along the near-surface leg veins

  5. On dynamics of uranium vein mineralization

    International Nuclear Information System (INIS)

    Petrosyan, R.V.

    1981-01-01

    The formation of urnaium vein deposits and the essence of consanguinity of the mineralization and wall metasomatites are considered. The formation of uranium mineralization is analysed from the positions of Korzhinsky D. S. : the formation of metasomatite aureole and associated vein ores take place as a result of the development of one solution flow while the formation of mineral vein associations occurs on the background of contineous filtration of the solution during metasomato is due to a repeated (pulse) half-opening of fractures and their filling with a part of filtrating solution. The analysis of the available information on the example of two different uranium manifestations permits to reveal certain relations both in the character of wall rock alterations and between the metasomatosis and the formation of ore minerals in veins. The conclusion is made that spatial-time correlations of vein formations with wall metasomatites attest that the pulse formation of ores in veinlets occurs on the background and in interrelation with a consecutive precipitation of components in the aureole volume. The analysis of element migration dynamics in wall aureole carried out from the positions of the Korzhinsky hypothesis of the advance wave of acid components that takes into account the interaction of continuous and pulse mechanisms of solution movement permits to avoid contradictions when interpreting the processes of wall rock alterations and vein ore-forming, and permits to make a common scheme of vein ore-genesis [ru

  6. Valsalva and gravitational variability of the internal jugular vein and common femoral vein: Ultrasound assessment

    Energy Technology Data Exchange (ETDEWEB)

    Beddy, P. [Department of Radiology, The Adelaide and Meath Hospital, Tallaght, Dublin 24 (Ireland)]. E-mail: pbeddy@eircom.net; Geoghegan, T. [Department of Radiology, The Adelaide and Meath Hospital, Tallaght, Dublin 24 (Ireland); Ramesh, N. [Department of Radiology, The Adelaide and Meath Hospital, Tallaght, Dublin 24 (Ireland); Buckley, O. [Department of Radiology, The Adelaide and Meath Hospital, Tallaght, Dublin 24 (Ireland); O' Brien, J. [Department of Radiology, The Adelaide and Meath Hospital, Tallaght, Dublin 24 (Ireland); Colville, J. [Department of Radiology, The Adelaide and Meath Hospital, Tallaght, Dublin 24 (Ireland); Torreggiani, W.C. [Department of Radiology, The Adelaide and Meath Hospital, Tallaght, Dublin 24 (Ireland)

    2006-05-15

    Purpose: Central venous cannulation via the common femoral vein is an important starting point for many interventions. The purpose of this study was to determine the optimum conditions for cannulation of the femoral vein and to compare these with the relative changes in the internal jugular vein. Methods: High-resolution 2D ultrasound was utilised to determine variability of the calibre of the femoral and internal jugular veins in 10 healthy subjects. Venous diameter was assessed during the Valsalva manoeuvre and in different degrees of the Trendelenburg position. Results: The Valsalva manoeuvre significantly increased the size of the femoral and internal jugular veins. There was a relatively greater increase in femoral vein diameter when compared with the internal jugular vein of 40 and 29%, respectively. Changes in body inclination (Trendelenburg position) did not significantly alter the luminal diameter of the femoral vein. However, it significantly increased internal jugular vein diameter. Conclusions: Femoral vein cannulation is augmented by the Valsalva manoeuvre but not significantly altered by the gravitational position of the subject.

  7. Anomalous adrenal vein anatomy complicating the evaluation of primary hyperaldosteronism

    Directory of Open Access Journals (Sweden)

    Kaitlin M. Ford, BS

    2018-02-01

    Full Text Available Adrenal vein development in utero occurs concurrently with the development of the inferior vena cava, the renal veins, and the gonadal veins. The embryologic formation of these veins involves communication of various venous systems. Although the left adrenal-renal vein complex is most commonly described as a shared emptying of the left adrenal vein and the left inferior phrenic vein into the left renal vein, there have been reports of numerous anatomic variations of this complex. In this report, we present a case of a rare variant of the left adrenal vein, in which the left adrenal vein empties into the left gonadal vein, which takes an atypical course superolateral to the left kidney.

  8. Human computer interaction using hand gestures

    CERN Document Server

    Premaratne, Prashan

    2014-01-01

    Human computer interaction (HCI) plays a vital role in bridging the 'Digital Divide', bringing people closer to consumer electronics control in the 'lounge'. Keyboards and mouse or remotes do alienate old and new generations alike from control interfaces. Hand Gesture Recognition systems bring hope of connecting people with machines in a natural way. This will lead to consumers being able to use their hands naturally to communicate with any electronic equipment in their 'lounge.' This monograph will include the state of the art hand gesture recognition approaches and how they evolved from their inception. The author would also detail his research in this area for the past 8 years and how the future might turn out to be using HCI. This monograph will serve as a valuable guide for researchers (who would endeavour into) in the world of HCI.

  9. Effect of a venotonic agent on the main arteries and veins during a 5 day HDT

    Science.gov (United States)

    Roumy, Jerome; Herault, Stephane; Tobal, Nathalie; Besnard, Stephane; Arbeille, Philippe

    2001-08-01

    Objective: To evaluate the cardiac, arterial and venous effect of a venotonic drug (Cirkan « Ck å) administrated orally daily to 6 subjects in HDT position during 5 days. These subjects underwent a second 5d HDT without Ck treatment one month later. Pre and post HDT the subjects were submitted to a stand test. Method: The cardiovascular parameters were measured by echography and Doppler. Results and discussion: The Cirkan treatment contributed to reduce the increase in cerebral resistance, and to maintain the lower limb resistance at a higher level than on controls. It reduces the vein section at the extremities (Jugular, femoral) and in the central vein system connected to the right heart (sub hepatics). On the other hand it increases the portal vein section which means that the blood stagnation at the splanchnic level is increased. Despite these arterial and venous significant modifications the clinical and ECG and Blood pressure response to the Stand test was similar in both groups.

  10. Recanalization after acute deep vein thrombosis

    Directory of Open Access Journals (Sweden)

    Gustavo Mucoucah Sampaio Brandao

    2013-12-01

    Full Text Available The process of recanalization of the veins of the lower limbs after an episode of acute deep venous thrombosis is part of the natural evolution of the remodeling of the venous thrombus in patients on anticoagulation with heparin and vitamin K inhibitors. This remodeling involves the complex process of adhesion of thrombus to the wall of the vein, the inflammatory response of the vessel wall leading to organization and subsequent contraction of the thrombus, neovascularization and spontaneous lysis of areas within the thrombus. The occurrence of spontaneous arterial flow in recanalized thrombosed veins has been described as secondary to neovascularization and is characterized by the development of flow patterns characteristic of arteriovenous fistulae that can be identified by color duplex scanning. In this review, we discuss some controversial aspects of the natural history of deep vein thrombosis to provide a better understanding of its course and its impact on venous disease.

  11. Complications of umbilical vein catherisation. Case Report

    International Nuclear Information System (INIS)

    Bothur-Nowacka, J.; Czech-Kowalska, J.; Gruszfeld, D.; Nowakowska-Rysz, M.; Dobrzanska, A.; Kosciesza, A.; Polnik, D.

    2011-01-01

    Umbilical vein catheterization is a relatively easy procedure performed routinely on the neonate intensive care units. It provides a fast central vein access, but some complications have been described in the literature. Case Reports: We presented a case report of a premature infant (34 hbd) with extravasation of the parenteral nutrition and drugs to the liver after umbilical vein catheterization. Fever and increasing biochemical markers of infection were observed. USG revealed a heterogenic, well-limited space of 4 cm in diameter, located in the right lobe of the liver. CT excluded liver abscess. Considering neoplastic process or incorrect location of the catheter of the central vein, we performed liver biopsy. Results: Cytological and biochemical analysis of the aspirated fluid revealed extravasation of parenteral nutrition to the liver.Our case confirms the necessity of controlling a proper location of the central catheter right after its insertion and during hospitalization. (authors)

  12. Osteoarthritis of the Hand

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is a Hand Surgeon? What is a Hand Therapist? Media Find a Hand Surgeon Home Anatomy Osteoarthritis Email to a friend * required fields From * ...

  13. Hands in Systemic Disease

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is ... Hand Therapist? Media Find a Hand Surgeon Home Anatomy ... hands, being composed of many types of tissue, including blood vessels, nerves, skin and skin-related tissues, bones, and muscles/tendons/ligaments, may show changes that reflect a ...

  14. Primary leiomyosarcoma of the innominate vein.

    Science.gov (United States)

    Illuminati, Giulio; Miraldi, Fabio; Mazzesi, Giuseppe; D'urso, Antonio; Ceccanei, Gianluca; Bezzi, Marcello

    2007-01-01

    Primary venous leiomyosarcoma is rare. We report the case of a primary leiomyosarcoma of the left innominate vein, with neoplastic thrombus extending into the left jugular and subclavian veins. The tumor was curatively resected en bloc with anterior mediastinal and laterocervical lymphatics, through a median sternotomy prolonged into left cervicotomy. Primary venous sarcomas may be associated with prolonged survival in individual cases, with curative resection recommended as the standard treatment, in the absence of distant spread.

  15. The umbilical and paraumbilical veins of man.

    OpenAIRE

    Martin, B F; Tudor, R G

    1980-01-01

    During its transit through the umbilicus structural changes occur in the thick wall of the extra-abdominal segment of the umbilical vein whereby the components of the intra-abdominal segment acquire an essentially longitudinal direction and become arranged in fibro-elastic and fibro-muscular zones. The vein lumen becomes largely obliterated by asymmetrical proliferation of loose subendothelial conective tissue. The latter forms a new inner zone within which a small segment of the lumen persis...

  16. Deep vein thrombosis of the leg

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Hee; Rhee, Kwang Woo; Jeon, Suk Chul; Joo, Kyung Bin; Lee, Seung Ro; Seo, Heung Suk; Hahm, Chang Kok [College of Medicine, Hanyang University, Seoul (Korea, Republic of)

    1987-04-15

    Ascending contrast venography is the definitive standard method for the diagnosis of deep vein thrombosis (DVT) of the lower extremities. Authors analysed 22 cases of DVT clinically and radiographically. 1.The patients ranged in age from 15 to 70 yrs and the most prevalent age group was 7th decade (31%). There was an equal distribution of males and females. 2.In 11 cases of 22 cases, variable etiologic factors were recognized, such as abdominal surgery, chronic bedridden state, local trauma on the leg, pregnancy, postpartum, Behcet's syndrome, iliac artery aneurysm, and chronic medication of estrogen. 3.Nineteen cases out of 22 cases showed primary venographic signs of DVT, such as well-defined filling defect in opacified veins and narrowed, irregularly filled venous lumen. In only 3 cases, the diagnosis of DVT was base upon the segmental nonvisualization of deep veins with good opacification of proximal and distal veins and presence of collaterals. 4.Extent of thrombosis: 3 cases were confined to calf vein, 4 cases extended to femoral vein, and 15 cases had involvement above iliac vein. 5.In 17 cases involving relatively long segment of deep veins, propagation pattern of thrombus was evaluated by its radiologic morphology according to the age of thrombus: 9 cases suggested central or antegrade propagation pattern and 8 cases, peripheral or retrograde pattern. 6.None of 22 cases showed clinical evidence of pulmonary embolism. The cause of the rarity of pulmonary embolism in Korean in presumed to be related to the difference in major involving site and propagation pattern of DVT in the leg.

  17. Deep vein thrombosis of the leg

    International Nuclear Information System (INIS)

    Lee, Eun Hee; Rhee, Kwang Woo; Jeon, Suk Chul; Joo, Kyung Bin; Lee, Seung Ro; Seo, Heung Suk; Hahm, Chang Kok

    1987-01-01

    Ascending contrast venography is the definitive standard method for the diagnosis of deep vein thrombosis (DVT) of the lower extremities. Authors analysed 22 cases of DVT clinically and radiographically. 1.The patients ranged in age from 15 to 70 yrs and the most prevalent age group was 7th decade (31%). There was an equal distribution of males and females. 2.In 11 cases of 22 cases, variable etiologic factors were recognized, such as abdominal surgery, chronic bedridden state, local trauma on the leg, pregnancy, postpartum, Behcet's syndrome, iliac artery aneurysm, and chronic medication of estrogen. 3.Nineteen cases out of 22 cases showed primary venographic signs of DVT, such as well-defined filling defect in opacified veins and narrowed, irregularly filled venous lumen. In only 3 cases, the diagnosis of DVT was base upon the segmental nonvisualization of deep veins with good opacification of proximal and distal veins and presence of collaterals. 4.Extent of thrombosis: 3 cases were confined to calf vein, 4 cases extended to femoral vein, and 15 cases had involvement above iliac vein. 5.In 17 cases involving relatively long segment of deep veins, propagation pattern of thrombus was evaluated by its radiologic morphology according to the age of thrombus: 9 cases suggested central or antegrade propagation pattern and 8 cases, peripheral or retrograde pattern. 6.None of 22 cases showed clinical evidence of pulmonary embolism. The cause of the rarity of pulmonary embolism in Korean in presumed to be related to the difference in major involving site and propagation pattern of DVT in the leg

  18. Isolated inferior mesenteric portal hypertension with giant inferior mesenteric vein and anomalous inferior mesenteric vein insertion

    Directory of Open Access Journals (Sweden)

    G Raghavendra Prasad

    2013-01-01

    Full Text Available Extrahepatic portal hypertension is not an uncommon disease in childhood, but isolated inferior mesenteric portal varices and lower gastrointestinal (GI bleed have not been reported till date. A 4-year-old girl presented with lower GI bleed. Surgical exploration revealed extrahepatic portal vein obstruction with giant inferior mesenteric vein and colonic varices. Inferior mesenteric vein was joining the superior mesenteric vein. The child was treated successfully with inferior mesenteric - inferior vena caval anastomosis. The child was relieved of GI bleed during the follow-up.

  19. Denmark: HAND in HAND Policy Questionnaire

    DEFF Research Database (Denmark)

    Laursen, Hilmar Dyrborg; Nielsen, Birgitte Lund

    2018-01-01

    Som del af det internationale EU finansierede projekt Hand in Hand, der fokuserer på de såkaldte SEI-kompetencer (Social, Emotional, Intercultural), er dansk policy i relation til elevernes sociale, emotionelle og interkulturelle læring kortlagt i denne rapport. Der refereres bl.a. til "elevernes...

  20. Veins improve fracture toughness of insect wings.

    Directory of Open Access Journals (Sweden)

    Jan-Henning Dirks

    Full Text Available During the lifetime of a flying insect, its wings are subjected to mechanical forces and deformations for millions of cycles. Defects in the micrometre thin membranes or veins may reduce the insect's flight performance. How do insects prevent crack related material failure in their wings and what role does the characteristic vein pattern play? Fracture toughness is a parameter, which characterises a material's resistance to crack propagation. Our results show that, compared to other body parts, the hind wing membrane of the migratory locust S. gregaria itself is not exceptionally tough (1.04±0.25 MPa√m. However, the cross veins increase the wing's toughness by 50% by acting as barriers to crack propagation. Using fracture mechanics, we show that the morphological spacing of most wing veins matches the critical crack length of the material (1132 µm. This finding directly demonstrates how the biomechanical properties and the morphology of locust wings are functionally correlated in locusts, providing a mechanically 'optimal' solution with high toughness and low weight. The vein pattern found in insect wings thus might inspire the design of more durable and lightweight artificial 'venous' wings for micro-air-vehicles. Using the vein spacing as indicator, our approach might also provide a basis to estimate the wing properties of endangered or extinct insect species.

  1. Transvenous liver biopsy via the femoral vein

    International Nuclear Information System (INIS)

    Khosa, F.; McNulty, J.G.; Hickey, N.; O'Brien, P.; Tobin, A.; Noonan, N.; Ryan, B.; Keeling, P.W.N.; Kelleher, D.P.; McDonald, G.S.A.

    2003-01-01

    AIM: To study the safety, effectiveness and diagnostic value of transvenous forceps biopsy of the liver in 54 patients with coagulopathy, gross ascites or morbid obesity and suspected liver disease in whom percutaneous liver biopsy was contraindicated. MATERIAL AND METHODS: Forceps biopsy of the liver via the femoral vein was attempted in 54 adult patients with advanced liver disease of unknown aetiology who had coagulation disorders (41 cases), gross ascites (11 cases) or morbid obesity (two cases). In each patient two to six biopsies (average four) were taken using a radial jaw forceps inserted via the right or left femoral vein. RESULTS: The procedure was successful in 53 cases. Hepatic vein catheterization failed in one patient. Adequate liver tissue for diagnosis was obtained in 84% of cases. One patient developed delayed haemorrhage at 12 h from a capsular leak that was undetected during the biopsy procedure. This patient required blood transfusions and laparotomy to control bleeding. There were no deaths in the 53 patients studied. Transient minor chest and shoulder pain was encountered during sheath insertion into a hepatic vein in 23 patients. Three patients developed a femoral vein haematoma, which resolved with conservative treatment. CONCLUSION: Transvenous liver biopsy via the femoral vein is another safe, effective, simple alternative technique of biopsy when the percutaneous route is contraindicated

  2. Does correlated color temperature affect the ability of humans to identify veins?

    DEFF Research Database (Denmark)

    Argyraki, Aikaterini; Clemmensen, Line Katrine Harder; Petersen, Paul Michael

    2016-01-01

    In the present study we provide empirical evidence and demonstrate statistically that white illumination settings can affect the human ability to identify veins in the inner hand vasculature. A special light-emitting diode lamp with high color rendering index (CRI 84–95) was developed and the eff......In the present study we provide empirical evidence and demonstrate statistically that white illumination settings can affect the human ability to identify veins in the inner hand vasculature. A special light-emitting diode lamp with high color rendering index (CRI 84–95) was developed...... and the effect of correlated color temperature was evaluated, in the range between 2600 and 5700 K at an illuminance of 40 9 lx on the ability of adult humans to identify veins. It is shown that the ability to identify veins can, on average, be increased up to 24% when white illumination settings that do...... not resemble incandescent light are applied. The illuminance reported together with the effect of white illumination settings on direct visual perception of biosamples are relevant for clinical investigations during the night. © 2015 Optical Society of America...

  3. Induced chorioretinal venous anastomosis in experimental retinal branch vein occlusion.

    OpenAIRE

    McAllister, I L; Yu, D Y; Vijayasekaran, S; Barry, C; Constable, I

    1992-01-01

    Iatrogenic retinal vein to choroidal vein anastomoses were created using laser photocoagulation in six of seven dog eyes in which a partial branch retinal vein occlusion had previously been created photochemically. A similar attempt to create an anastomosis was made in six control eyes in which no branch vein occlusion was present. In the eyes in which a branch retinal vein had been created, a venous chorioretinal anastomosis appeared to be present by 3 to 6 weeks. In three control eyes simil...

  4. The CT appearance of the superior intercostal veins

    International Nuclear Information System (INIS)

    Lund, G.

    1982-01-01

    The CT appearance of the superior intercostal veins is described. The veins are more frequently seen on the right side. The right superior intercostal vein should not be misinterpreted as a paraspinal mass when it is large or bulges into the contour of the right lung. A case of stenosis of the left brachiocephalic vein is shown, where the left superior intercostal vein serves as a collateral. (orig.)

  5. Duplication of the Portal Vein: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Won; Shin, Hyeong Cheol; Jou, Sung Shick; Han, Jong Kyu; Kim, Il Young [Soonchunhyang University Cheonan Hospital, Cheonan (Korea, Republic of)

    2009-12-15

    The duplication of the portal vein is an uncommon congenital anomaly. To date, only four cases have been reported in the medical literature. This anomaly can cause portal hypertension in pediatric patients. In addition, duplication of the portal vein has various patterns of connection with a splenic vein or mesenteric veins, and it can lie anterior or posterior to the duodenum. We report the MDCT findings of an adult patient with duplication of the portal vein that was found incidentally

  6. Gonadal vein tumor thrombosis due to renal cell carcinoma

    Directory of Open Access Journals (Sweden)

    Hamidreza Haghighatkhah

    2015-01-01

    Full Text Available Renal cell carcinoma (RCC had a tendency to extend into the renal vein and inferior vena cava, while extension into the gonadal vein has been rarely reported. Gonadal vein tumor thrombosis appears as an enhancing filling defect within the dilated gonadal vein anterior to the psoas muscle and shows an enhancement pattern identical to that of the original tumor. The possibility of gonadal vein thrombosis should be kept in mind when looking at an imaging study of patients with RCC

  7. Robotic hand project

    OpenAIRE

    Karaçizmeli, Cengiz; Çakır, Gökçe; Tükel, Dilek

    2014-01-01

    In this work, the mechatronic based robotic hand is controlled by the position data taken from the glove which has flex sensors mounted to capture finger bending of the human hand. The angular movement of human hand’s fingers are perceived and processed by a microcontroller, and the robotic hand is controlled by actuating servo motors. It has seen that robotic hand can simulate the movement of the human hand that put on the glove, during tests have done. This robotic hand can be used not only...

  8. Corrosion cast study of the canine hepatic veins.

    Science.gov (United States)

    Uršič, M; Vrecl, M; Fazarinc, G

    2014-11-01

    This study presents a detailed description of the distribution, diameters and drainage patterns of hepatic veins on the basis of the corrosion cast analysis in 18 dogs. We classified the hepatic veins in three main groups: the right hepatic veins of the caudate process and right lateral liver lobe, the middle hepatic veins of the right medial and quadrate lobes and the left hepatic veins of both left liver lobes and the papillary process. The corrosion cast study showed that the number of the veins in the Nomina Anatomica Veterinaria and most anatomical textbooks is underestimated. The number of various-sized hepatic veins of the right liver division ranged from 3 to 5 and included 1 to 4 veins from the caudate process and 2 to 4 veins from the right lateral liver lobe. Generally, in all corrosion casts, one middle-sized vein from the right part of the right medial lobe, which emptied separately in the caudal vena cava, was established. The other vein was a large-sized vein from the remainder of the central division, which frequently joined the common left hepatic vein from the left liver lobes. The common left hepatic vein was the largest of all the aforementioned hepatic veins.

  9. Modulation of pathogen recognition by autophagy

    Directory of Open Access Journals (Sweden)

    Ji Eun eOh

    2012-03-01

    Full Text Available Autophagy is an ancient biological process for maintaining cellular homeostasis by degradation of long-lived cytosolic proteins and organelles. Recent studies demonstrated that autophagy is availed by immune cells to regulate innate immunity. On the one hand, cells exert direct effector function by degrading intracellular pathogens; on the other hand, autophagy modulates pathogen recognition and downstream signaling for innate immune responses. Pathogen recognition via pattern recognition receptors induces autophagy. The function of phagocytic cells is enhanced by recruitment of autophagy-related proteins. Moreover, autophagy acts as a delivery system for viral replication complexes to migrate to the endosomal compartments where virus sensing occurs. In another case, key molecules of the autophagic pathway have been found to negatively regulate immune signaling, thus preventing aberrant activation of cytokine production and consequent immune responses. In this review, we focus on the recent advances in the role of autophagy in pathogen recognition and modulation of innate immune responses.

  10. Umbilical vein draining into the inferior vena cava via the internal iliac vein, bypassing the liver

    International Nuclear Information System (INIS)

    Currarino, G.; Stannard, M.W.; Texas Univ., Dallas, TX; Kolni, H.

    1991-01-01

    This is the third report of an anomalous umbilical vein draining ectopically in a left pelvic vein, probably the left internal iliac, and through the inferior vena cava into the right atrium. The anomaly was encountered in a newborn infant with nonimmune hydrops fetalis, hypertrophic cardiomyopathy, multiorgan failure and possibly Noonan Syndrome. (orig.)

  11. Umbilical vein draining into the inferior vena cava via the internal iliac vein, bypassing the liver

    Energy Technology Data Exchange (ETDEWEB)

    Currarino, G.; Stannard, M.W. (Children' s Medical Center, Dallas, TX (United States). Dept. of Radiology Texas Univ., Dallas, TX (United States). Southwestern Medical Center); Kolni, H. (Methodist Hospital, Dallas, TX (United States). Dept. of Pediatrics)

    1991-05-01

    This is the third report of an anomalous umbilical vein draining ectopically in a left pelvic vein, probably the left internal iliac, and through the inferior vena cava into the right atrium. The anomaly was encountered in a newborn infant with nonimmune hydrops fetalis, hypertrophic cardiomyopathy, multiorgan failure and possibly Noonan Syndrome. (orig.).

  12. Animal Model of Acute Deep Vein Thrombosis

    International Nuclear Information System (INIS)

    Roy, Sumit; Laerum, Frode; Brosstad, Frank; Kvernebo, Knut; Sakariassen, Kjell S.

    1998-01-01

    Purpose: To develop an animal model of acute deep vein thrombosis (DVT). Methods: In part I of the study nine juvenile domestic pigs were used. Each external iliac vein was transluminally occluded with a balloon catheter. Thrombin was infused through a microcatheter in one leg according to one of the following protocols: (1) intraarterial (IA): 1250 U at 25 U/min in the common femoral artery (n= 3); (2) intravenous (IV): 5000 U in the popliteal vein at 500 U/min (n= 3), or at 100 U/min (n= 3). Saline was administered in the opposite leg. After the animals were killed, the mass of thrombus in the iliofemoral veins was measured. The pudendoepiploic (PEV), profunda femoris (PF), and popliteal veins (PV) were examined. Thrombosis in the tributaries of the superficial femoral vein (SFVt) was graded according to a three-point scale (0, +, ++). In part II of the study IV administration was further investigated in nine pigs using the following three regimens with 1000 U at 25 U/min serving as the control: (1) 1000 U at 100 U/min, (2) 250 U at 25 U/min, (3) 250 U at 6.25 U/min. Results: All animals survived. In part I median thrombus mass in the test limbs was 1.40 g as compared with 0.25 g in the controls (p= 0.01). PEV, PFV and PV were thrombosed in all limbs infused with thrombin. IV infusion was more effective in inducing thrombosis in both the parent veins (mass 1.32-1.78 g) and SVFt (++ in 4 of 6 legs), as compared with IA infusion (mass 0.0-1.16 g; SFVt ++ in 1 of 3 legs). In part II thrombus mass in axial veins ranged from 1.23 to 2.86 g, and showed no relationship with the dose of thrombin or the rate of infusion. Tributary thrombosis was less extensive with 250 U at 25 U/min than with the other regimens. Conclusion: Slow distal intravenous thrombin infusion in the hind legs of pigs combined with proximal venous occlusion induces thrombosis in the leg veins that closely resembles clinical DVT in distribution

  13. Clean Hands Count

    Medline Plus

    Full Text Available ... to promote or encourage adherence to CDC hand hygiene recommendations. It is a component of the Clean ... aims to address myths and misperceptions about hand hygiene and empower patients to play a role in ...

  14. Clean Hands Count

    Medline Plus

    Full Text Available ... intended to promote or encourage adherence to CDC hand hygiene recommendations. It is a component of the Clean ... also aims to address myths and misperceptions about hand hygiene and empower patients to play a role in ...

  15. Clean Hands Count

    Science.gov (United States)

    ... intended to promote or encourage adherence to CDC hand hygiene recommendations. It is a component of the Clean ... also aims to address myths and misperceptions about hand hygiene and empower patients to play a role in ...

  16. Wash Your Hands

    Science.gov (United States)

    ... hand sanitizers might not remove harmful chemicals like pesticides and heavy metals from hands. Be cautious when ... Health Promotion Materials Fact Sheets Podcasts Posters Stickers Videos Web Features Training & Education Our Partners Publications, Data & ...

  17. Management of reticular veins and telangiectases.

    Science.gov (United States)

    Smith, Philip Coleridge

    2015-11-01

    To review the literature related to the management of reticular varices and telangiectases of the lower limbs to provide guidance on the treatment of these veins. Very few randomised clinical trials are available in this field. A European Guideline has been published on the treatment of reticular varices and telangiectases, which is largely based on the opinion of experts. Older accounts written by individual phlebologists contain extensive advice from their own practice, which is valuable in identifying effective methods of sclerotherapy. All accounts indicate that a history should be taken combined with a clinical and ultrasound examination to establish the full extent of the venous disease. Sclerotherapy is commenced by injecting the larger veins first of all, usually the reticular varices. Later in the same session or in subsequent sessions, telangiectases can be treated by direct injection. Following treatment, the application of class 2 compression stockings for a period of up to three weeks is beneficial but not used universally by all phlebologists. Further sessions can follow at intervals of 2-8 weeks in which small residual veins are treated. Resistant veins can be managed by ultrasound-guided injection of underlying perforating veins and varices. Other treatments including RF diathermy and laser ablation of telangiectases have very limited efficacy in this condition. Sclerotherapy, when used with the correct technique, is the most effective method for the management of reticular varices and telangiectases. © The Author(s) 2015.

  18. Hand hygiene strategies

    OpenAIRE

    Yazaji, Eskandar Alex

    2011-01-01

    Hand hygiene is one of the major players in preventing healthcare associated infections. However, healthcare workers compliance with hand hygiene continues to be a challenge. This article will address strategies to help improving hand hygiene compliance. Keywords: hand hygiene; healthcare associated infections; multidisciplinary program; system change; accountability; education; feedback(Published: 18 July 2011)Citation: Journal of Community Hospital Internal Medicine Perspectives 2011, 1: 72...

  19. Ligation of superior mesenteric vein and portal to splenic vein anastomosis after superior mesenteric-portal vein confluence resection during pancreaticoduodenectomy – Case report

    Science.gov (United States)

    Tang, Jianlin; Abbas, Jihad; Hoetzl, Katherine; Allison, David; Osman, Mahamed; Williams, Mallory; Zelenock, Gerald B.

    2014-01-01

    62 year old Caucasian female with pancreatic head mass abutting the superior mesenteric vein (SMV) presented with fine needle aspiration biopsy confirmed diagnosis of ductal adenocarcinoma. CT scan showed near complete obstruction of portal vein and large SMV collateral development. After 3 months of neoadjuvant therapy, her portal vein flow improved significantly, SMV collateral circulation was diminished. Pancreaticoduodenectomy (PD) and superior mesenteric portal vein (SMPV) confluence resection were performed; A saphenous vein interposition graft thrombosed immediately. The splenic vein remnant was distended and adjacent to the stump of the portal vein. Harvesting an internal jugular vein graft required extra time and using a synthetic graft posed a risk of graft thrombosis or infection. As a result, we chose to perform a direct anastomosis of the portal and splenic vein in a desperate situation. The anastomosis decompressed the mesenteric venous system, so we then ligated the SMV. The patient had an uneventful postoperative course, except transient ascites. She redeveloped ascites more than one year later. At that time a PET scan showed bilateral lung and right femur metastatic disease. She expired 15 months after PD. Conclusion The lessons we learned are (1) Before SMPV confluence resection, internal jugular vein graft should be ready for reconstruction. (2) Synthetic graft is an alternative for internal jugular vein graft. (3) Direct portal vein to SMV anastomosis can be achieved by mobilizing liver. (4) It is possible that venous collaterals secondary to SMV tumor obstruction may have allowed this patient's post-operative survival. PMID:25568802

  20. Ligation of superior mesenteric vein and portal to splenic vein anastomosis after superior mesenteric-portal vein confluence resection during pancreaticoduodenectomy - Case report.

    Science.gov (United States)

    Tang, Jianlin; Abbas, Jihad; Hoetzl, Katherine; Allison, David; Osman, Mahamed; Williams, Mallory; Zelenock, Gerald B

    2014-12-01

    62 year old Caucasian female with pancreatic head mass abutting the superior mesenteric vein (SMV) presented with fine needle aspiration biopsy confirmed diagnosis of ductal adenocarcinoma. CT scan showed near complete obstruction of portal vein and large SMV collateral development. After 3 months of neoadjuvant therapy, her portal vein flow improved significantly, SMV collateral circulation was diminished. Pancreaticoduodenectomy (PD) and superior mesenteric portal vein (SMPV) confluence resection were performed; A saphenous vein interposition graft thrombosed immediately. The splenic vein remnant was distended and adjacent to the stump of the portal vein. Harvesting an internal jugular vein graft required extra time and using a synthetic graft posed a risk of graft thrombosis or infection. As a result, we chose to perform a direct anastomosis of the portal and splenic vein in a desperate situation. The anastomosis decompressed the mesenteric venous system, so we then ligated the SMV. The patient had an uneventful postoperative course, except transient ascites. She redeveloped ascites more than one year later. At that time a PET scan showed bilateral lung and right femur metastatic disease. She expired 15 months after PD. The lessons we learned are (1) Before SMPV confluence resection, internal jugular vein graft should be ready for reconstruction. (2) Synthetic graft is an alternative for internal jugular vein graft. (3) Direct portal vein to SMV anastomosis can be achieved by mobilizing liver. (4) It is possible that venous collaterals secondary to SMV tumor obstruction may have allowed this patient's post-operative survival.

  1. About Hand Surgery

    Science.gov (United States)

    ... Find a hand surgeon near you. © 2009 American Society for Surgery of the Hand. Definition developed by ASSH Council. Other Links CME Mission Statement and Disclaimer Policies and Technical Requirements Exhibits and Partners ASSH 822 W. Washington Blvd. ... 2018 by American Society for Surgery of the Hand × Search Tips Tip ...

  2. Guideline Implementation: Hand Hygiene.

    Science.gov (United States)

    Goldberg, Judith L

    2017-02-01

    Performing proper hand hygiene and surgical hand antisepsis is essential to reducing the rates of health care-associated infections, including surgical site infections. The updated AORN "Guideline for hand hygiene" provides guidance on hand hygiene and surgical hand antisepsis, the wearing of fingernail polish and artificial nails, proper skin care to prevent dermatitis, the wearing of jewelry, hand hygiene product selection, and quality assurance and performance improvement considerations. This article focuses on key points of the guideline to help perioperative personnel make informed decisions about hand hygiene and surgical hand antisepsis. The key points address the necessity of keeping fingernails and skin healthy, not wearing jewelry on the hands or wrists in the perioperative area, properly performing hand hygiene and surgical hand antisepsis, and involving patients and visitors in hand hygiene initiatives. Perioperative RNs should review the complete guideline for additional information and for guidance when writing and updating policies and procedures. Copyright © 2017 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  3. Robotic hand and fingers

    Science.gov (United States)

    Salisbury, Curt Michael; Dullea, Kevin J.

    2017-06-06

    Technologies pertaining to a robotic hand are described herein. The robotic hand includes one or more fingers releasably attached to a robotic hand frame. The fingers can abduct and adduct as well as flex and tense. The fingers are releasably attached to the frame by magnets that allow for the fingers to detach from the frame when excess force is applied to the fingers.

  4. Enrollment Time as a Requirement for Biometric Hand Recognition Systems

    OpenAIRE

    Carvalho, João; Sá, Vítor; Tenreiro de Magalhães, Sérgio; Santos, Henrique

    2015-01-01

    Biometric systems are increasingly being used as a means for authentication to provide system security in modern technologies. The performance of a biometric system depends on the accuracy, the processing speed, the template size, and the time necessary for enrollment. While much research has focused on the first three factors, enrollment time has not received as much attention. In this work, we present the findings of our research focused upon studying user’s behavior when enrolling in...

  5. Deep vein thrombosis: a clinical review

    Directory of Open Access Journals (Sweden)

    Kesieme EB

    2011-04-01

    Full Text Available Emeka Kesieme1, Chinenye Kesieme2, Nze Jebbin3, Eshiobo Irekpita1, Andrew Dongo11Department of Surgery, Irrua Specialist Teaching Hospital, Irrua, Nigeria; 2Department of Paediatrics, Irrua Specialist Teaching Hospital, Irrua, Nigeria; 3Department of Surgery, University of Port Harcourt Teaching Hospital, Port-Harcourt, NigeriaBackground: Deep vein thrombosis (DVT is the formation of blood clots (thrombi in the deep veins. It commonly affects the deep leg veins (such as the calf veins, femoral vein, or popliteal vein or the deep veins of the pelvis. It is a potentially dangerous condition that can lead to preventable morbidity and mortality.Aim: To present an update on the causes and management of DVT.Methods: A review of publications obtained from Medline search, medical libraries, and Google.Results: DVT affects 0.1% of persons per year. It is predominantly a disease of the elderly and has a slight male preponderance. The approach to making a diagnosis currently involves an algorithm combining pretest probability, D-dimer testing, and compression ultrasonography. This will guide further investigations if necessary. Prophylaxis is both mechanical and pharmacological. The goals of treatment are to prevent extension of thrombi, pulmonary embolism, recurrence of thrombi, and the development of complications such as pulmonary hypertension and post-thrombotic syndrome.Conclusion: DVT is a potentially dangerous condition with a myriad of risk factors. Prophylaxis is very important and can be mechanical and pharmacological. The mainstay of treatment is anticoagulant therapy. Low-molecular-weight heparin, unfractionated heparin, and vitamin K antagonists have been the treatment of choice. Currently anticoagulants specifically targeting components of the common pathway have been recommended for prophylaxis. These include fondaparinux, a selective indirect factor Xa inhibitor and the new oral selective direct thrombin inhibitors (dabigatran and selective

  6. Epidemiological study on varicose veins in Budapest.

    Science.gov (United States)

    Bihari, I; Tornoci, L; Bihari, P

    2012-03-01

    To analyse the prevalence and risk factors of varicose veins and chronic venous disease in Budapest. Data were collected using a questionnaire, as well as by performing physical and Doppler ultrasound examination of 566 adult inhabitants of Budapest and some neighbouring villages. The prevalence of lower-extremity varicose veins was 57.1% in the study population. Verified risk factors include advancing age, pregnancy, jobs requiring a lot of standing, blue-collar work and excess body weight. Neither female gender nor the use of oral contraceptives or hormone replacement therapy was identified as a contributing factor. Hungarian prevalence data and risk factors seem to be similar to other European countries.

  7. Superficial Vein Thrombophlebitis in a Football Athlete.

    Science.gov (United States)

    Schleich, Kevin T; Smoot, M Kyle

    2016-03-01

    A 22-year-old professional football player presented to a preparticipation physical examination with a 2-week history of left leg discomfort extending from the groin to the knee over the previous 2 weeks. He was found to have superficial vein thrombophlebitis (SVT) of the left great saphenous vein extending from the knee to within approximately 1.6 cm of the saphenofemoral junction. There is paucity in the literature regarding the management of SVT, particularly in actively training athletes. This case addresses the considerations of anticoagulation management for SVT as well as the unique challenge of managing anticoagulation therapy in an athlete that is actively training.

  8. Pattern Recognition

    Directory of Open Access Journals (Sweden)

    Aleš Procházka

    2018-05-01

    Full Text Available Multimodal signal analysis based on sophisticated sensors, efficient communicationsystems and fast parallel processing methods has a rapidly increasing range of multidisciplinaryapplications. The present paper is devoted to pattern recognition, machine learning, and the analysisof sleep stages in the detection of sleep disorders using polysomnography (PSG data, includingelectroencephalography (EEG, breathing (Flow, and electro-oculogram (EOG signals. The proposedmethod is based on the classification of selected features by a neural network system with sigmoidaland softmax transfer functions using Bayesian methods for the evaluation of the probabilities of theseparate classes. The application is devoted to the analysis of the sleep stages of 184 individualswith different diagnoses, using EEG and further PSG signals. Data analysis points to an averageincrease of the length of the Wake stage by 2.7% per 10 years and a decrease of the length of theRapid Eye Movement (REM stages by 0.8% per 10 years. The mean classification accuracy for givensets of records and single EEG and multimodal features is 88.7% ( standard deviation, STD: 2.1 and89.6% (STD:1.9, respectively. The proposed methods enable the use of adaptive learning processesfor the detection and classification of health disorders based on prior specialist experience andman–machine interaction.

  9. An unusual case: right proximal ureteral compression by the ovarian vein and distal ureteral compression by the external iliac vein

    Directory of Open Access Journals (Sweden)

    Halil Ibrahim Serin

    2015-12-01

    Full Text Available A 32-years old woman presented to the emergency room of Bozok University Research Hospital with right renal colic. Multidetector computed tomography (MDCT showed compression of the proximal ureter by the right ovarian vein and compression of the right distal ureter by the right external iliac vein. To the best of our knowledge, right proximal ureteral compression by the ovarian vein together with distal ureteral compression by the external iliac vein have not been reported in the literature. Ovarian vein and external iliac vein compression should be considered in patients presenting to the emergency room with renal colic or low back pain and a dilated collecting system.

  10. Hand hygiene in the intensive care unit.

    Science.gov (United States)

    Tschudin-Sutter, Sarah; Pargger, Hans; Widmer, Andreas F

    2010-08-01

    Healthcare-associated infections affect 1.4 million patients at any time worldwide, as estimated by the World Health Organization. In intensive care units, the burden of healthcare-associated infections is greatly increased, causing additional morbidity and mortality. Multidrug-resistant pathogens are commonly involved in such infections and render effective treatment challenging. Proper hand hygiene is the single most important, simplest, and least expensive means of preventing healthcare-associated infections. In addition, it is equally important to stop transmission of multidrug-resistant pathogens. According to the Centers for Disease Control and Prevention and World Health Organization guidelines on hand hygiene in health care, alcohol-based handrub should be used as the preferred means for routine hand antisepsis. Alcohols have excellent in vitro activity against Gram-positive and Gram-negative bacteria, including multidrug-resistant pathogens, such as methicillin-resistant Staphylococcus aureus and vancomycin-resistant enterococci, Mycobacterium tuberculosis, a variety of fungi, and most viruses. Some pathogens, however, such as Clostridium difficile, Bacillus anthracis, and noroviruses, may require special hand hygiene measures. Failure to provide user friendliness of hand hygiene equipment and shortage of staff are predictors for noncompliance, especially in the intensive care unit setting. Therefore, practical approaches to promote hand hygiene in the intensive care unit include provision of a minimal number of handrub dispensers per bed, monitoring of compliance, and choice of the most attractive product. Lack of knowledge of guidelines for hand hygiene, lack of recognition of hand hygiene opportunities during patient care, and lack of awareness of the risk of cross-transmission of pathogens are barriers to good hand hygiene practices. Multidisciplinary programs to promote increased use of alcoholic handrub lead to an increased compliance of healthcare

  11. Endovascular Radiofrequency Ablation for Varicose Veins

    Science.gov (United States)

    2011-01-01

    Executive Summary Objective The objective of the MAS evidence review was to conduct a systematic review of the available evidence on the safety, effectiveness, durability and cost–effectiveness of endovascular radiofrequency ablation (RFA) for the treatment of primary symptomatic varicose veins. Background The Ontario Health Technology Advisory Committee (OHTAC) met on August 26th, 2010 to review the safety, effectiveness, durability, and cost-effectiveness of RFA for the treatment of primary symptomatic varicose veins based on an evidence-based review by the Medical Advisory Secretariat (MAS). Clinical Condition Varicose veins (VV) are tortuous, twisted, or elongated veins. This can be due to existing (inherited) valve dysfunction or decreased vein elasticity (primary venous reflux) or valve damage from prior thrombotic events (secondary venous reflux). The end result is pooling of blood in the veins, increased venous pressure and subsequent vein enlargement. As a result of high venous pressure, branch vessels balloon out leading to varicosities (varicose veins). Symptoms typically affect the lower extremities and include (but are not limited to): aching, swelling, throbbing, night cramps, restless legs, leg fatigue, itching and burning. Left untreated, venous reflux tends to be progressive, often leading to chronic venous insufficiency (CVI). A number of complications are associated with untreated venous reflux: including superficial thrombophlebitis as well as variceal rupture and haemorrhage. CVI often results in chronic skin changes referred to as stasis dermatitis. Stasis dermatitis is comprised of a spectrum of cutaneous abnormalities including edema, hyperpigmentation, eczema, lipodermatosclerosis and stasis ulceration. Ulceration represents the disease end point for severe CVI. CVI is associated with a reduced quality of life particularly in relation to pain, physical function and mobility. In severe cases, VV with ulcers, QOL has been rated to be as bad

  12. Transcutaneous laser treatment of leg veins

    NARCIS (Netherlands)

    Meesters, Arne A.; Pitassi, Luiza H. U.; Campos, Valeria; Wolkerstorfer, Albert; Dierickx, Christine C.

    2014-01-01

    Leg telangiectasias and reticular veins are a common complaint affecting more than 80% of the population to some extent. To date, the gold standard remains sclerotherapy for most patients. However, there may be some specific situations, where sclerotherapy is contraindicated such as needle phobia,

  13. Puerperal ovarian vein thrombosis: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Won Sik; Jeon, Woo Ki; Han, Chang Yul [Inje College Paik Hospital, Pusan (Korea, Republic of)

    1989-08-15

    Puerperal ovarian vein thrombophlebitis(POVT) is a postpartum complication that requires prompt medical treatment to avoid extension of thrombus with potentially life-threatening complications. The prompt noninvasive diagnosing method is CT that defines the location and the extent about the thrombus. There findings will supply future case to be definitely diagnosed and treated without invasive procedures.

  14. Endovascular vein harvest: systemic carbon dioxide absorption.

    Science.gov (United States)

    Maslow, Andrew M; Schwartz, Carl S; Bert, Arthur; Hurlburt, Peter; Gough, Jeffrey; Stearns, Gary; Singh, Arun K

    2006-06-01

    Endovascular vein harvest (EDVH) requires CO(2) insufflation to expand the subcutaneous space, allowing visualization and dissection of the saphenous vein. The purpose of this study was to assess the extent of CO(2) absorption during EDVH. Prospective observational study. Single tertiary care hospital. Sixty patients (30 EDVH and 30 open-vein harvest) undergoing isolated coronary artery bypass graft surgery. Hemodynamic, procedural, and laboratory data were collected prior to (baseline), during, and at it the conclusion (final) of vein harvesting. Data were also collected during cardiopulmonary bypass (CPB). Data were compared by using t tests, analysis of variance, and correlation statistics when needed. There were significant increases in arterial CO(2) (PaCO(2), 35%) and decreases in pH (1.35%) during EDVH. These were associated with increases in heart rate, mean blood pressure, and cardiac output. Within the EDVH group, greater elevations (>10 mmHg) in PaCO2 were more likely during difficult harvest procedures, and these patients exhibited greater increase in heart rate. Elevated CO(2) persisted during CPB, requiring higher systemic gas flows and greater use of phenylephrine to maintain desired hemodynamics. EDVH was associated with systemic absorption of CO(2). Greater absorption was more likely in difficult procedures and was associated with greater hemodynamic changes requiring medical therapy.

  15. What Are Varicose Veins? (For Kids)

    Science.gov (United States)

    ... Recipes for Kids Kids site Sitio para niños How the Body Works Puberty & Growing Up Staying Healthy Staying Safe Recipes & ... those body parts are farthest from the heart. Gravity pulls blood down into your ... down. So the veins have to work extra hard to get that blood back up ...

  16. The Avocado Hand

    LENUS (Irish Health Repository)

    Rahmani, G

    2017-11-01

    Accidental self-inflicted knife injuries to digits are a common cause of tendon and nerve injury requiring hand surgery. There has been an apparent increase in avocado related hand injuries. Classically, the patients hold the avocado in their non-dominant hand while using a knife to cut\\/peel the fruit with their dominant hand. The mechanism of injury is usually a stabbing injury to the non-dominant hand as the knife slips past the stone, through the soft avocado fruit. Despite their apparent increased incidence, we could not find any cases in the literature which describe the “avocado hand”. We present a case of a 32-year-old woman who sustained a significant hand injury while preparing an avocado. She required exploration and repair of a digital nerve under regional anaesthesia and has since made a full recovery.

  17. Hand eczema classification

    DEFF Research Database (Denmark)

    Diepgen, T L; Andersen, Klaus Ejner; Brandao, F M

    2008-01-01

    of the disease is rarely evidence based, and a classification system for different subdiagnoses of hand eczema is not agreed upon. Randomized controlled trials investigating the treatment of hand eczema are called for. For this, as well as for clinical purposes, a generally accepted classification system...... A classification system for hand eczema is proposed. Conclusions It is suggested that this classification be used in clinical work and in clinical trials....

  18. Varicose Veins: Role of Mechanotransduction of Venous Hypertension

    Science.gov (United States)

    Atta, Hussein M.

    2012-01-01

    Varicose veins affect approximately one-third of the adult population and result in significant psychological, physical, and financial burden. Nevertheless, the molecular pathogenesis of varicose vein formation remains unidentified. Venous hypertension exerted on veins of the lower extremity is considered the principal factor in varicose vein formation. The role of mechanotransduction of the high venous pressure in the pathogenesis of varicose vein formation has not been adequately investigated despite a good progress in understanding the mechanomolecular mechanisms involved in transduction of high blood pressure in the arterial wall. Understanding the nature of the mechanical forces, the mechanosensors and mechanotransducers in the vein wall, and the downstream signaling pathways will provide new molecular targets for the prevention and treatment of varicose veins. This paper summarized the current understanding of mechano-molecular pathways involved in transduction of hemodynamic forces induced by blood pressure and tries to relate this information to setting of venous hypertension in varicose veins. PMID:22489273

  19. Incidental retroaortic left innominate vein in adult patient

    Directory of Open Access Journals (Sweden)

    Alexandre Semionov, MD, PhD

    2017-09-01

    Full Text Available Retro-aortic left innominate vein is a rare vascular abnormality, usually associated with congenital heart disease. Here we report a case of isolated retro-aortic left innominate vein in an adult female.

  20. Coordination of hand shape.

    Science.gov (United States)

    Pesyna, Colin; Pundi, Krishna; Flanders, Martha

    2011-03-09

    The neural control of hand movement involves coordination of the sensory, motor, and memory systems. Recent studies have documented the motor coordinates for hand shape, but less is known about the corresponding patterns of somatosensory activity. To initiate this line of investigation, the present study characterized the sense of hand shape by evaluating the influence of differences in the amount of grasping or twisting force, and differences in forearm orientation. Human subjects were asked to use the left hand to report the perceived shape of the right hand. In the first experiment, six commonly grasped items were arranged on the table in front of the subject: bottle, doorknob, egg, notebook, carton, and pan. With eyes closed, subjects used the right hand to lightly touch, forcefully support, or imagine holding each object, while 15 joint angles were measured in each hand with a pair of wired gloves. The forces introduced by supporting or twisting did not influence the perceptual report of hand shape, but for most objects, the report was distorted in a consistent manner by differences in forearm orientation. Subjects appeared to adjust the intrinsic joint angles of the left hand, as well as the left wrist posture, so as to maintain the imagined object in its proper spatial orientation. In a second experiment, this result was largely replicated with unfamiliar objects. Thus, somatosensory and motor information appear to be coordinated in an object-based, spatial-coordinate system, sensitive to orientation relative to gravitational forces, but invariant to grasp forcefulness.

  1. A biometric authentication model using hand gesture images.

    Science.gov (United States)

    Fong, Simon; Zhuang, Yan; Fister, Iztok; Fister, Iztok

    2013-10-30

    A novel hand biometric authentication method based on measurements of the user's stationary hand gesture of hand sign language is proposed. The measurement of hand gestures could be sequentially acquired by a low-cost video camera. There could possibly be another level of contextual information, associated with these hand signs to be used in biometric authentication. As an analogue, instead of typing a password 'iloveu' in text which is relatively vulnerable over a communication network, a signer can encode a biometric password using a sequence of hand signs, 'i' , 'l' , 'o' , 'v' , 'e' , and 'u'. Subsequently the features from the hand gesture images are extracted which are integrally fuzzy in nature, to be recognized by a classification model for telling if this signer is who he claimed himself to be, by examining over his hand shape and the postures in doing those signs. It is believed that everybody has certain slight but unique behavioral characteristics in sign language, so are the different hand shape compositions. Simple and efficient image processing algorithms are used in hand sign recognition, including intensity profiling, color histogram and dimensionality analysis, coupled with several popular machine learning algorithms. Computer simulation is conducted for investigating the efficacy of this novel biometric authentication model which shows up to 93.75% recognition accuracy.

  2. "CEPHALIC VEIN ANATOMY IN ANTECUBITAL FOSSA DURING THE CONSTRUCTION OF ARTERIOVENOUS FISTULA"

    Directory of Open Access Journals (Sweden)

    S. M. Alamshah

    2004-08-01

    Full Text Available In order to create an effective arteriovenous fistula (AVF in patients with sustained chronic renal failure (CRF, surgeons need to become familiar with various anatomical variations of venous structures in the operating field. Because of variety and different types of cubital venous anatomies, there is more than a 90% possibility of creating suitable AVFs in the cubital fossa , but in the wrist and forearm, due to old injections and thrombophlebitis, there is less chance to do so. Since cephalic vein is the main venous conduit for constructing an AVF in the antecubital region, this study focuses on the various anatomical variations of cephalic vein and its communicating branches. We studied the cubital cephalic anatomy of 103 patients with CRF during construction of an AVF from July 1999 to June 2001. Five types of cephalic vein anatomy were seen: type A (44.66%, type B (30.1%, type C (18.44%, type D (3.88% and type E (2.29% in 39 right and 64 left arms. Seventy-six anastomoses were performed to brachial trunk, 25 to the radial and 2 to the ulnar artery. Eleven cases with progressive swelling after AVF were uneventfully cured by hand elevation. No infection, false aneurysm, venous hypertension or steal syndrome was detected. In order to obtain the best results and select appropriate operative technique for reliable vascular access in CRF, it is necessary to understand the anatomical variety of cephalic vein.

  3. Adventitial cystic disease of the common femoral vein presenting as deep vein thrombosis

    Directory of Open Access Journals (Sweden)

    Young-Kyun Kim

    2016-07-01

    Full Text Available Adventitial cystic disease of the common femoral vein is a rare condition. We herein report the case of a 50-year-old woman who presented with painless swelling in her left lower leg that resembled deep vein thrombosis. She underwent femoral exploration and excision of the cystic wall. The presentation, investigation, treatment, and pathology of this condition are discussed with a literature review.

  4. Vein visualization: patient characteristic factors and efficacy of a new infrared vein finder technology.

    Science.gov (United States)

    Chiao, F B; Resta-Flarer, F; Lesser, J; Ng, J; Ganz, A; Pino-Luey, D; Bennett, H; Perkins, C; Witek, B

    2013-06-01

    We investigated the patient characteristic factors that correlate with identification of i.v. cannulation sites with normal eyesight. We evaluated a new infrared vein finding (VF) technology device in identifying i.v. cannulation sites. Each subject underwent two observations: one using the conventional method (CM) of normal, unassisted eyesight and the other with the infrared VF device, VueTek's Veinsite™ (VF). A power analysis for moderate effect size (β=0.95) required 54 samples for within-subject differences. Patient characteristic profiles were obtained from 384 subjects (768 observations). Our sample population exhibited an overall average of 5.8 [95% confidence interval (CI) 5.4-6.2] veins using CM. As a whole, CM vein visualization were less effective among obese [4.5 (95% CI 3.8-5.3)], African-American [4.6 (95% CI 3.6-5.5 veins)], and Asian [5.1 (95% CI 4.1-6.0)] subjects. Next, the VF technology identified an average of 9.1 (95% CI 8.6-9.5) possible cannulation sites compared with CM [average of 5.8 (95% CI 5.4-6.2)]. Seventy-six obese subjects had an average of 4.5 (95% CI 3.8-5.3) and 8.2 (95% CI 7.4-9.1) veins viewable by CM and VF, respectively. In dark skin subjects, 9.1 (95% CI 8.3-9.9) veins were visible by VF compared with 5.4 (95% CI 4.8-6.0) with CM. African-American or Asian ethnicity, and obesity were associated with decreased vein visibility. The visibility of veins eligible for cannulation increased for all subgroups using a new infrared device.

  5. Observation of the human body thermoregulation and extraction of its vein signature using NIR and MWIR imaging

    Science.gov (United States)

    Bouzida, Nabila; Bendada, Abdelhakim; Maldague, Xavier P.

    2009-05-01

    The article aims first to present a new study on the thermal regulatory response of the human skin surface while exposed to a cold environment. Our work has shown that when a cold stress is applied to the left hand, thermal infrared imaging (MWIR spectral band: 3-5 μm) allows a clear observation of a temperature rise on the right hand. Moreover, a frequency analysis was also carried out upon selected vein pixels of the images monitored during the same cold stress experiment. The objective was to identify the specific frequencies that could be linked to some physiological mechanisms of the human body. This kind of study could be very useful for the characterization of possible thermo-physiological pathologies. Besides thermoregulation, we also present in this article some results on the extraction of the hand vein pattern. Firstly, we show some vein extraction results obtained after image processing of the thermal images recorded in the thermal band (MWIR), then we compare this vein pattern to the signature obtained with a camera operating in the NIR spectral band (0.85-1.7 μm). This method could be used as a complementary means for finger print signatures in biometrics.

  6. Dexamethasone Implant (Ozurdex in a Case with Unilateral Simultaneous Central Retinal Vein and Branch Retinal Artery Occlusion

    Directory of Open Access Journals (Sweden)

    Taylan Ozturk

    2015-02-01

    Full Text Available Simultaneous branch retinal artery and vein occlusion is a rare condition that may cause severe visual loss, and its treatment is often unrewarding. Herein, we report a case with simultaneous central retinal vein and branch retinal artery occlusion; it was successfully treated with a single dexamethasone intravitreal implant. The affected eye attained a visual acuity level of 20/25 from the visual acuity of hand motions at presentation with a residual, but relatively diminished, altitudinal scotoma during a follow-up period of 6 months.

  7. Palliative treatment of TIPS to portal vein tumor thrombosis complicated with portal vein hypertension

    International Nuclear Information System (INIS)

    Jiang Zaibo; Shan Hong; Guan Shouhai; Zhu Kangshun; Huang Mingsheng; Li Zhengran; Guo Tiansheng; Liu Lang

    2002-01-01

    Objective: To evaluate the palliative therapeutic effects of transjugular intrahepatic portosystemic shunt (TIPS) in portal vein tumor thrombosis (PVTT) complicated with portal vein hypertension, and to discuss the technical skills. Methods: There were 14 cases of end-stage hepatocellular carcinoma complicated with PVTT and portal vein hypertension, the average age was 53.6 yr. There were 8 cases with complete occlusion of main portal vein, 6 eases with incomplete thrombosis, and 5 cases combined with portal vein cavernous transformation. One case had simple hemorrhage, 3 eases had intractable ascites, and 10 cases had hemorrhage accompanied by intractable ascites. Results: The procedure of TIPS was successful in 10 cases, the successful rate was about 71%. The mean portal vein pressure was reduced from 37.2 mm Hg to 18.2 mm Hg, with an average reduction of 19.0 mm Hg. After the procedure of TIPS, the ascites decreased, hemorrhage stopped and the clinical symptoms disappeared. The average survival period was 132.3 days. The procedure were failing in 4 cases. Conclusion: TIPS was an effective palliative therapeutic methods to control the hemorrhage and ascites aroused by hepatic carcinoma complicated with PVTT

  8. Recognition of sign language gestures using neural networks

    Directory of Open Access Journals (Sweden)

    Simon Vamplew

    2007-04-01

    Full Text Available This paper describes the structure and performance of the SLARTI sign language recognition system developed at the University of Tasmania. SLARTI uses a modular architecture consisting of multiple feature-recognition neural networks and a nearest-neighbour classifier to recognise Australian sign language (Auslan hand gestures.

  9. Recognition of sign language gestures using neural networks

    OpenAIRE

    Simon Vamplew

    2007-01-01

    This paper describes the structure and performance of the SLARTI sign language recognition system developed at the University of Tasmania. SLARTI uses a modular architecture consisting of multiple feature-recognition neural networks and a nearest-neighbour classifier to recognise Australian sign language (Auslan) hand gestures.

  10. Unconstrained and contactless hand geometry biometrics.

    Science.gov (United States)

    de-Santos-Sierra, Alberto; Sánchez-Ávila, Carmen; Del Pozo, Gonzalo Bailador; Guerra-Casanova, Javier

    2011-01-01

    This paper presents a hand biometric system for contact-less, platform-free scenarios, proposing innovative methods in feature extraction, template creation and template matching. The evaluation of the proposed method considers both the use of three contact-less publicly available hand databases, and the comparison of the performance to two competitive pattern recognition techniques existing in literature: namely support vector machines (SVM) and k-nearest neighbour (k-NN). Results highlight the fact that the proposed method outcomes existing approaches in literature in terms of computational cost, accuracy in human identification, number of extracted features and number of samples for template creation. The proposed method is a suitable solution for human identification in contact-less scenarios based on hand biometrics, providing a feasible solution to devices with limited hardware requirements like mobile devices.

  11. Unconstrained and Contactless Hand Geometry Biometrics

    Directory of Open Access Journals (Sweden)

    Carmen Sánchez-Ávila

    2011-10-01

    Full Text Available This paper presents a hand biometric system for contact-less, platform-free scenarios, proposing innovative methods in feature extraction, template creation and template matching. The evaluation of the proposed method considers both the use of three contact-less publicly available hand databases, and the comparison of the performance to two competitive pattern recognition techniques existing in literature: namely Support Vector Machines (SVM and k-Nearest Neighbour (k-NN. Results highlight the fact that the proposed method outcomes existing approaches in literature in terms of computational cost, accuracy in human identification, number of extracted features and number of samples for template creation. The proposed method is a suitable solution for human identification in contact-less scenarios based on hand biometrics, providing a feasible solution to devices with limited hardware requirements like mobile devices.

  12. Reconstruction of hand contracture by reverse ulnar perforator flap

    Directory of Open Access Journals (Sweden)

    Cengiz Eser

    2016-04-01

    Full Text Available Hand burn scar contractures affect patients in aesthetic and functional aspects. After releasing these scars, the defects should be repaired. The reconstruction methods include primary suturation, Z plasty, skin grafting, local or free flaps, etc. All methods have their own advantages and disadvantages. One of the most useful flaps is the reverse ulnar perforator flap. We performed a two-staged procedure for repairing a post-burn contracture release defect in a 40-year-old male. In the first stage we applied reverse ulnar perforator flap for the hand defect, and ulnar artery and vein repair in the second stage. In conclusion, this two-staged procedure is a non-primary but useful option for hand and finger defects and prevents major vascular structure damage of the forearm. [Hand Microsurg 2016; 5(1.000: 40-43

  13. Clean Hands Count

    Medline Plus

    Full Text Available ... 585 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 413,097 ... 089,212 views 4:50 Hand hygiene FULL music video - Duration: 2:33. AlfredHealthTV 26,032 views ...

  14. Mind the hand

    DEFF Research Database (Denmark)

    Davidsen, Jacob; Christiansen, Ellen Tove

    2014-01-01

    Apart from touching the screen, what is the role of the hands for children collaborating around touchscreens? Based on embodied and multimodal interaction analysis of 8- and 9-year old pairs collaborating around touchscreens, we conclude that children use their hands to constrain and control acce...

  15. Clean Hands Count

    Medline Plus

    Full Text Available ... 024 views 2:58 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 412,404 ... 2,805 views 3:13 Hand hygiene FULL music video - Duration: 2:33. AlfredHealthTV 25,574 views ...

  16. HAND INJURIES IN VOLLEYBALL

    NARCIS (Netherlands)

    BHAIRO, NH; NIJSTEN, MWN; VANDALEN, KC; TENDUIS, HJ

    We studied the long-term sequelae of hand injuries as a result of playing volleyball. In a retrospective study, 226 patients with injuries of the hand who were seen over a 5-year period at our Trauma Department, were investigated. Females accounted for 66 % of all injuries. The mean age was 26

  17. Clean Hands Count

    Medline Plus

    Full Text Available ... 585 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 412,760 ... 536,963 views 1:46 Hand hygiene FULL music video - Duration: 2:33. AlfredHealthTV 25,574 views ...

  18. Clean Hands Count

    Medline Plus

    Full Text Available ... today; no cure tomorrow - Duration: 3:10. World Health Organization 74,478 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 411,292 views 5:46 Hand Washing Technique - ...

  19. Clean Hands Count

    Medline Plus

    Full Text Available ... 029 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 412,404 ... 081,511 views 4:50 Hand hygiene FULL music video - Duration: 2:33. AlfredHealthTV 25,194 views ...

  20. Clean Hands Count

    Medline Plus

    Full Text Available ... today; no cure tomorrow - Duration: 3:10. World Health Organization 75,362 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 412,404 views 5:46 Hand Washing Technique - ...

  1. Clean Hands Count

    Medline Plus

    Full Text Available ... 585 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 413,097 ... 086,746 views 4:50 Hand hygiene FULL music video - Duration: 2:33. AlfredHealthTV 25,802 views ...

  2. Clean Hands Count

    Medline Plus

    Full Text Available ... 453 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 413,702 ... 28,656 views 3:40 Hand hygiene FULL music video - Duration: 2:33. AlfredHealthTV 26,480 views ...

  3. Clean Hands Count

    Medline Plus

    Full Text Available ... 362 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 412,404 ... 219,427 views 1:27 Hand hygiene FULL music video - Duration: 2:33. AlfredHealthTV 25,194 views ...

  4. Clean Hands Count

    Medline Plus

    Full Text Available ... 03. R Mayer 371,490 views 4:03 The psychological trick behind getting people to say yes - Duration: 8:06. PBS NewsHour 606,671 views 8:06 Should You Really Wash Your Hands? - Duration: 4:51. Gross Science 57,828 views 4:51 Healthcare Worker Hand ...

  5. Clean Hands Count

    Medline Plus

    Full Text Available ... 585 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 413,097 ... 28,656 views 3:40 Hand hygiene FULL music video - Duration: 2:33. AlfredHealthTV 26,032 views ...

  6. Clean Hands Count

    Medline Plus

    Full Text Available ... 5 Moments of Hand Hygiene - Duration: 1:53. Salem Health 13,972 views 1:53 Hand Hygiene ... Mode: Off History Help Loading... Loading... Loading... About Press Copyright Creators Advertise Developers +YouTube Terms Privacy Policy & ...

  7. "Puffy hand syndrome".

    Science.gov (United States)

    Chouk, Mickaël; Vidon, Claire; Deveza, Elise; Verhoeven, Frank; Pelletier, Fabien; Prati, Clément; Wendling, Daniel

    2017-01-01

    Intravenous drug addiction is responsible for many complications, especially cutaneous and infectious. There is a syndrome, rarely observed in rheumatology, resulting in "puffy hands": the puffy hand syndrome. We report two cases of this condition from our rheumatologic consultation. Our two patients had intravenous drug addiction. They presented with an edema of the hands, bilateral, painless, no pitting, occurring in one of our patient during heroin intoxication, and in the other 2 years after stopping injections. In our two patients, additional investigations (biological, radiological, ultrasound) were unremarkable, which helped us, in the context, to put the diagnosis of puffy hand syndrome. The pathophysiology, still unclear, is based in part on a lymphatic toxicity of drugs and their excipients. There is no etiological treatment but elastic compression by night has improved edema of the hands in one of our patients. Copyright © 2016 Société française de rhumatologie. Published by Elsevier SAS. All rights reserved.

  8. iHand: an interactive bare-hand-based augmented reality interface on commercial mobile phones

    Science.gov (United States)

    Choi, Junyeong; Park, Jungsik; Park, Hanhoon; Park, Jong-Il

    2013-02-01

    The performance of mobile phones has rapidly improved, and they are emerging as a powerful platform. In many vision-based applications, human hands play a key role in natural interaction. However, relatively little attention has been paid to the interaction between human hands and the mobile phone. Thus, we propose a vision- and hand gesture-based interface in which the user holds a mobile phone in one hand but sees the other hand's palm through a built-in camera. The virtual contents are faithfully rendered on the user's palm through palm pose estimation, and reaction with hand and finger movements is achieved that is recognized by hand shape recognition. Since the proposed interface is based on hand gestures familiar to humans and does not require any additional sensors or markers, the user can freely interact with virtual contents anytime and anywhere without any training. We demonstrate that the proposed interface works at over 15 fps on a commercial mobile phone with a 1.2-GHz dual core processor and 1 GB RAM.

  9. Ligation of superior mesenteric vein and portal to splenic vein anastomosis after superior mesenteric-portal vein confluence resection during pancreaticoduodenectomy – Case report

    Directory of Open Access Journals (Sweden)

    Jianlin Tang

    2014-12-01

    Conclusion: The lessons we learned are (1 Before SMPV confluence resection, internal jugular vein graft should be ready for reconstruction. (2 Synthetic graft is an alternative for internal jugular vein graft. (3 Direct portal vein to SMV anastomosis can be achieved by mobilizing liver. (4 It is possible that venous collaterals secondary to SMV tumor obstruction may have allowed this patient's post-operative survival.

  10. Lower extremity dep vein thrombosis in children

    International Nuclear Information System (INIS)

    Perlmutt, L.; Fellows, K.E.; Harvard Medical School, Boston, MA

    1983-01-01

    Of 113 leg venograms performed in patients of all ages between 1969 and 1982, 68 were in children 16 years old or less. The patients were all studied on a tilt table (method of Rabinov and Paulin) in a head-up, 40-50 0 incline without tourniquets, supporting their weight on the unaffected leg. Among the 68 venograms, 12 (18%) were positive for deep vein thrombosis. The clinical settings for thrombosis in children were post-catheterization (two patients), post surgery (two), tumor/tumor therapy (three), drug abuse (one), and idiopathic (three). There were no long-term clinical sequelae in five patients. Pulmonary infarction occurred in three, and three patients required either long-term anticoagulation or IVC clipping. Clinical diagnosis is no more accurate for the diagnosis of deep vein thrombosis in children than it is in adults. Venography is the best method for making an accurate diagnosis and directing subsequent therapy.(orig.)

  11. Varicose vein therapy and nerve lesions.

    Science.gov (United States)

    Hirsch, Tobias

    2017-03-01

    Treating varicose veins using endovenous thermal techniques - especially laser and radio frequency ablation - has emerged as an effective alternative to open surgery with stripping and high ligation. Even though these methods are very gentle and patient-friendly, they are nevertheless accompanied by risks and side effects. Compared to open surgical therapy, the risk of damage to peripheral and motor nerves is reduced; however, it still exists as a result of heat exposure and tumescent anaesthesia. Non-thermal methods that can be applied without tumescent anaesthesia have been introduced to the market. They pose a considerably lower risk of nerve lesions while proving to be much more effective. This paper investigates data on postoperative nerve damage and paraesthesia using internet research (PubMed). It analyses the current state of knowledge regarding non-thermal treatment methods and takes into account the latest developments in the use of cyanoacrylate to close insufficient saphenous veins.

  12. Thrombosed aneurysm of saphenous vein coronary artery bypass grafting

    Energy Technology Data Exchange (ETDEWEB)

    Queiroz, Rodolfo Mendes; Nastri Filho, Rogerio; Ferez, Marcus Antonio; Costa, Mauro Jose Brandao da; Laguna, Claudio Benedini; Valentin, Marcus Vinicius Nascimento, E-mail: rod_queiroz@hotmail.com [Documenta - Hospital Sao Francisco, Ribeirao Preto, SP (Brazil). Departamento de Radiologia e Diagnostico por Imagem; Hospital Sao Francisco, Ribeirao Preto, SP (Brazil). Centro de Terapia Intensiva

    2017-06-15

    We describe the case of a male patient, aged 76 years, referred for cardiac investigation due to retrosternal chest pain and dyspnea. He had a history of acute myocardial infarction and angioplasties in the last 30 years, including a saphenous vein coronary artery bypass grafting (SVCABG). Echocardiogram showed hypoechoic oval formation near the right ventricle, suggesting a pericardial cyst. Computed angiotomography revealed a predominantly fusiform and thrombosed aneurysmal dilation of the SVCABG to the right coronary artery. SVCABG aneurysms are very rare and potentially fatal. They usually appear in the late postoperative period, and patients are often asymptomatic. On radiography, it is frequently presented as enlargement of the mediastinum, with echocardiography, computed tomography and magnetic resonance imaging being very useful for diagnosis. Coronary angiography is the gold standard to detect these cases. Our report illustrates a rare situation arising late from a relatively common surgery. Due to its severity, proper recognition in the routine assessment of patients with a similar history is essential. (author)

  13. (In)Visible Hand(s)

    OpenAIRE

    Predrag Zima

    2007-01-01

    In this paper, the author discusses the regulatory role of the state and legal norms, in market economy, especially in so-called transition countries. Legal policy, and other questions of the state and free market economy are here closely connected, because the state must ensure with legal norms that economic processes are not interrupted: only the state can establish the legal basis for a market economy. The free market’s invisible hand is acting in questions such as: what is to be produced,...

  14. Finger vein extraction using gradient normalization and principal curvature

    Science.gov (United States)

    Choi, Joon Hwan; Song, Wonseok; Kim, Taejeong; Lee, Seung-Rae; Kim, Hee Chan

    2009-02-01

    Finger vein authentication is a personal identification technology using finger vein images acquired by infrared imaging. It is one of the newest technologies in biometrics. Its main advantage over other biometrics is the low risk of forgery or theft, due to the fact that finger veins are not normally visible to others. Extracting finger vein patterns from infrared images is the most difficult part in finger vein authentication. Uneven illumination, varying tissues and bones, and changes in the physical conditions and the blood flow make the thickness and brightness of the same vein different in each acquisition. Accordingly, extracting finger veins at their accurate positions regardless of their thickness and brightness is necessary for accurate personal identification. For this purpose, we propose a new finger vein extraction method which is composed of gradient normalization, principal curvature calculation, and binarization. As local brightness variation has little effect on the curvature and as gradient normalization makes the curvature fairly uniform at vein pixels, our method effectively extracts finger vein patterns regardless of the vein thickness or brightness. In our experiment, the proposed method showed notable improvement as compared with the existing methods.

  15. Prevention of hand eczema

    DEFF Research Database (Denmark)

    Fisker, Maja H; Ebbehøj, Niels E; Vejlstrup, Søren Grove

    2018-01-01

    Objective Occupational hand eczema has adverse health and socioeconomic impacts for the afflicted individuals and society. Prevention and treatment strategies are needed. This study aimed to assess the effectiveness of an educational intervention on sickness absence, quality of life and severity...... of hand eczema. Methods PREVEX (PreVention of EXema) is an individually randomized, parallel-group superiority trial investigating the pros and cons of one-time, 2-hour, group-based education in skin-protective behavior versus treatment as usual among patients with newly notified occupational hand eczema...

  16. Brucellosis associated with deep vein thrombosis.

    Science.gov (United States)

    Tolaj, Ilir; Mehmeti, Murat; Ramadani, Hamdi; Tolaj, Jasmina; Dedushi, Kreshnike; Fejza, Hajrullah

    2014-11-19

    Over the past 10 years more than 700 cases of brucellosis have been reported in Kosovo, which is heavily oriented towards agriculture and animal husbandry. Here, brucellosis is still endemic and represents an uncontrolled public health problem. Human brucellosis may present with a broad spectrum of clinical manifestations; among them, vascular complications are uncommon. Hereby we describe the case of a 37-year-old male patient with brucellosis complicated by deep vein thrombosis on his left leg.

  17. Angiographic investigation of the male gonadal vein

    International Nuclear Information System (INIS)

    Vajda, J.; Boehm, K.; Horvath, L.; Molnar, Z.

    1980-01-01

    Retrograde angiography of the gonadal vein was carried out in 110 cases. Because of valve-insufficience the left vena spermatica interna filled spontaneously from the vena renalis in the majority (88%) of the cases. In the cases of well functioning valves superselective angiography was carried out. The examination is advised in cases of the following syndromes: varicokele, abdominal tumours, determination of the place of non-palpable testes, Klinefelter syndrome. (L.E.)

  18. Deep vein thrombosis: diagnosis, treatment, and prevention

    Energy Technology Data Exchange (ETDEWEB)

    Stewart, W.P.; Youngswick, F.D.

    Deep vein thrombosis (DVT) is a dangerous complication that may present after elective foot surgery. Because of the frequency with which DVT occurs in the elderly patient, as well as in the podiatric surgical population, the podiatrist should be acquainted with this entity. A review of the diagnosis, treatment, prevention, and the role of podiatry in the management of DVT is discussed in this paper.

  19. Brucellosis associated with deep vein thrombosis

    Directory of Open Access Journals (Sweden)

    Ilir Tolaj

    2014-11-01

    Full Text Available Over the past 10 years more than 700 cases of brucellosis have been reported in Kosovo, which is heavily oriented towards agriculture and animal husbandry. Here, brucellosis is still endemic and represents an uncontrolled public health problem. Human brucellosis may present with a broad spectrum of clinical manifestations; among them, vascular complications are uncommon. Hereby we describe the case of a 37-year-old male patient with brucellosis complicated by deep vein thrombosis on his left leg.

  20. Brucellosis Associated with Deep Vein Thrombosis

    Science.gov (United States)

    Tolaj, Ilir; Mehmeti, Murat; Ramadani, Hamdi; Tolaj, Jasmina; Dedushi, Kreshnike; Fejza, Hajrullah

    2014-01-01

    Over the past 10 years more than 700 cases of brucellosis have been reported in Kosovo, which is heavily oriented towards agriculture and animal husbandry. Here, brucellosis is still endemic and represents an uncontrolled public health problem. Human brucellosis may present with a broad spectrum of clinical manifestations; among them, vascular complications are uncommon. Hereby we describe the case of a 37-year-old male patient with brucellosis complicated by deep vein thrombosis on his left leg. PMID:25568754

  1. Brucellosis Associated with Deep Vein Thrombosis

    OpenAIRE

    Tolaj, Ilir; Mehmeti, Murat; Ramadani, Hamdi; Tolaj, Jasmina; Dedushi, Kreshnike; Fejza, Hajrullah

    2014-01-01

    Over the past 10 years more than 700 cases of brucellosis have been reported in Kosovo, which is heavily oriented towards agriculture and animal husbandry. Here, brucellosis is still endemic and represents an uncontrolled public health problem. Human brucellosis may present with a broad spectrum of clinical manifestations; among them, vascular complications are uncommon. Hereby we describe the case of a 37-year-old male patient with brucellosis complicated by deep vein thrombosis on his left ...

  2. Absent right superior caval vein in situs solitus

    DEFF Research Database (Denmark)

    Lytzen, Rebekka; Sundberg, Karin; Vejlstrup, Niels

    2015-01-01

    Introduction In up to 0.07% of the general population, the right anterior cardinal vein obliterates and the left remains open, creating an absent right superior caval vein and a persistent left superior caval vein. Absent right superior caval vein is associated with additional congenital heart...... disease in about half the patients. We wished to study the consequences of absent right superior caval vein as an incidental finding on prenatal ultrasonic malformation screening. Material and methods This is a retrospective case series study of all foetuses diagnosed with absent right superior caval vein...... no postnatal complications. All children were found to have healthy hearts at follow-up. CONCLUSIONS: In all cases, the findings proved to be a benign condition with no clinical manifestations or complications. Although isolated absent right superior caval vein does not seem to affect the outcome, associated...

  3. Diagnostic imagings and embolotherapy for the superior mesenteric vein-inferior vena cava shunt

    International Nuclear Information System (INIS)

    Morita, Yutaka; Yamada, Masataka; Miyata, Mutsuhiko; Kubo, Kohzo.

    1994-01-01

    Diagnostic imaging and embolization therapy for the uncommon portal and mesenteric vein-inferior vena cave shunt (PV·SMV-IVC shunt) are reported. As the frequency of clinical symptoms such as hematemesis, melena and confusion caused by gastrointestinal varices, or hepatoencephalopathy was about 40%, it was important for this disease entity to be diagnosed with noninvasive diagnostic images. The careful examination of the area around the right renal vein was able to overcome the low diagnostic rate of 20-40% obtained with US and CT images. In cases of simple PV·SMV-IVC shut without gastrointestinal varices, embolization therapy using steel coils and done by the intravenous approach is easy and noninvasive. On the other hand, in cases of complex PV-SMV-IVC shunt with gastrointestinal varices, dual balloon occluded embolization therapy using a liquid sclerosing agent and done by the intravenous and portal approaches is preferable. (author)

  4. Laser photocoagulation for retinal vein occlusion

    Directory of Open Access Journals (Sweden)

    K. A. Mirzabekova

    2015-03-01

    Full Text Available Retinal vein occlusion (RVO is one of the leading causes of permanent vision loss. In adults, central retinal vein occlusion (CRVO occurs in 1.8% while branch retinal vein occlusion (BRVO occurs in 0.2%. Treatment strategy and disease prognosis are determined by RVO type (ischemic/non-ischemic. Despite numerous studies and many current CRVO and BRVO treatment approaches, the management of these patients is still being debated. Intravitreal injections of steroids (triamcinolone acetate, dexamethasone and vascular endothelial growth factor (VEGF inhibitors (bevacizumab, ranibizumab were shown to be fairly effective. However, it is unclear whether anti-VEGF agents are reasonable in ischemic RVOs. Laser photocoagulation remains the only effective treatment of optic nerve head and/or retinal neovascularization. Laser photocoagulation is also indicated for the treatment of macular edema. Both threshold and sub-threshold photocoagulation may be performed. Photocoagulation performed with argon (514 nm, krypton (647 nm, or diode (810 nm laser for macular edema provides similar results (no significant differences. The treatment may be complex and include medication therapy and/or surgery. Medication therapy includes anti-aggregant agents and antioxidants, i.e., emoxypine which may be used in acute RVO as well as in post-thrombotic retinopathy. 

  5. Laser photocoagulation for retinal vein occlusion

    Directory of Open Access Journals (Sweden)

    K. A. Mirzabekova

    2015-01-01

    Full Text Available Retinal vein occlusion (RVO is one of the leading causes of permanent vision loss. In adults, central retinal vein occlusion (CRVO occurs in 1.8% while branch retinal vein occlusion (BRVO occurs in 0.2%. Treatment strategy and disease prognosis are determined by RVO type (ischemic/non-ischemic. Despite numerous studies and many current CRVO and BRVO treatment approaches, the management of these patients is still being debated. Intravitreal injections of steroids (triamcinolone acetate, dexamethasone and vascular endothelial growth factor (VEGF inhibitors (bevacizumab, ranibizumab were shown to be fairly effective. However, it is unclear whether anti-VEGF agents are reasonable in ischemic RVOs. Laser photocoagulation remains the only effective treatment of optic nerve head and/or retinal neovascularization. Laser photocoagulation is also indicated for the treatment of macular edema. Both threshold and sub-threshold photocoagulation may be performed. Photocoagulation performed with argon (514 nm, krypton (647 nm, or diode (810 nm laser for macular edema provides similar results (no significant differences. The treatment may be complex and include medication therapy and/or surgery. Medication therapy includes anti-aggregant agents and antioxidants, i.e., emoxypine which may be used in acute RVO as well as in post-thrombotic retinopathy. 

  6. Metabolic effects of portal vein sensing.

    Science.gov (United States)

    Mithieux, G

    2014-09-01

    The extrinsic gastrointestinal nerves are crucial in the sensing of nutrients and hormones and its translation in terms of control of food intake. Major macronutrients like glucose and protein are sensed by the extrinsic nerves located in the portal vein walls, which signal to the brain and account for the satiety phenomenon they promote. Glucose is sensed in the portal vein by neurons expressing the glucose receptor SGLT3, which activate the main regions of the brain involved in the control of food intake. Proteins indirectly act on food intake by inducing intestinal gluconeogenesis and its sensing by the portal glucose sensor. The mechanism involves a prior antagonism by peptides of the μ-opioid receptors present in the portal vein nervous system and a reflex arc with the brain inducing intestinal gluconeogenesis. In a comparable manner, short-chain fatty acids produced from soluble fibre act via intestinal gluconeogenesis to exert anti-obesity and anti-diabetic effects. In the case of propionate, the mechanism involves a prior activation of the free fatty acid receptor FFAR3 present in the portal nerves and a reflex arc initiating intestinal gluconeogenesis. © 2014 John Wiley & Sons Ltd.

  7. Patterning of leaf vein networks by convergent auxin transport pathways.

    Science.gov (United States)

    Sawchuk, Megan G; Edgar, Alexander; Scarpella, Enrico

    2013-01-01

    The formation of leaf vein patterns has fascinated biologists for centuries. Transport of the plant signal auxin has long been implicated in vein patterning, but molecular details have remained unclear. Varied evidence suggests a central role for the plasma-membrane (PM)-localized PIN-FORMED1 (PIN1) intercellular auxin transporter of Arabidopsis thaliana in auxin-transport-dependent vein patterning. However, in contrast to the severe vein-pattern defects induced by auxin transport inhibitors, pin1 mutant leaves have only mild vein-pattern defects. These defects have been interpreted as evidence of redundancy between PIN1 and the other four PM-localized PIN proteins in vein patterning, redundancy that underlies many developmental processes. By contrast, we show here that vein patterning in the Arabidopsis leaf is controlled by two distinct and convergent auxin-transport pathways: intercellular auxin transport mediated by PM-localized PIN1 and intracellular auxin transport mediated by the evolutionarily older, endoplasmic-reticulum-localized PIN6, PIN8, and PIN5. PIN6 and PIN8 are expressed, as PIN1 and PIN5, at sites of vein formation. pin6 synthetically enhances pin1 vein-pattern defects, and pin8 quantitatively enhances pin1pin6 vein-pattern defects. Function of PIN6 is necessary, redundantly with that of PIN8, and sufficient to control auxin response levels, PIN1 expression, and vein network formation; and the vein pattern defects induced by ectopic PIN6 expression are mimicked by ectopic PIN8 expression. Finally, vein patterning functions of PIN6 and PIN8 are antagonized by PIN5 function. Our data define a new level of control of vein patterning, one with repercussions on other patterning processes in the plant, and suggest a mechanism to select cell files specialized for vascular function that predates evolution of PM-localized PIN proteins.

  8. Patterning of leaf vein networks by convergent auxin transport pathways.

    Directory of Open Access Journals (Sweden)

    Megan G Sawchuk

    Full Text Available The formation of leaf vein patterns has fascinated biologists for centuries. Transport of the plant signal auxin has long been implicated in vein patterning, but molecular details have remained unclear. Varied evidence suggests a central role for the plasma-membrane (PM-localized PIN-FORMED1 (PIN1 intercellular auxin transporter of Arabidopsis thaliana in auxin-transport-dependent vein patterning. However, in contrast to the severe vein-pattern defects induced by auxin transport inhibitors, pin1 mutant leaves have only mild vein-pattern defects. These defects have been interpreted as evidence of redundancy between PIN1 and the other four PM-localized PIN proteins in vein patterning, redundancy that underlies many developmental processes. By contrast, we show here that vein patterning in the Arabidopsis leaf is controlled by two distinct and convergent auxin-transport pathways: intercellular auxin transport mediated by PM-localized PIN1 and intracellular auxin transport mediated by the evolutionarily older, endoplasmic-reticulum-localized PIN6, PIN8, and PIN5. PIN6 and PIN8 are expressed, as PIN1 and PIN5, at sites of vein formation. pin6 synthetically enhances pin1 vein-pattern defects, and pin8 quantitatively enhances pin1pin6 vein-pattern defects. Function of PIN6 is necessary, redundantly with that of PIN8, and sufficient to control auxin response levels, PIN1 expression, and vein network formation; and the vein pattern defects induced by ectopic PIN6 expression are mimicked by ectopic PIN8 expression. Finally, vein patterning functions of PIN6 and PIN8 are antagonized by PIN5 function. Our data define a new level of control of vein patterning, one with repercussions on other patterning processes in the plant, and suggest a mechanism to select cell files specialized for vascular function that predates evolution of PM-localized PIN proteins.

  9. Comparison between mechanical properties of human saphenous vein and umbilical vein

    Directory of Open Access Journals (Sweden)

    Hamedani Borhan

    2012-08-01

    Full Text Available Abstract Background As a main cause of mortality in developed countries, Coronary Artery Disease (CAD is known as silent killer with a considerable cost to be dedicated for its treatment. Coronary Artery Bypass Graft (CABG is a common remedy for CAD for which different blood vessels are used as a detour. There is a lack of knowledge about mechanical properties of human blood vessels used for CABG, and while these properties have a great impact on long-term patency of a CABG. Thus, studying these properties, especially those of human umbilical veins which have not been considered yet, looks utterly necessary. Methods Umbilical vein, as well as human Saphenous vein, are respectively obtained after cesarean and CABG. First, histological tests were performed to investigate different fiber contents of the samples. Having prepared samples carefully, force-displacement results of samples were rendered to real stress–strain measurements and then a fourth-order polynomial was used to prove the non-linear behavior of these two vessels. Results Results were analyzed in two directions, i.e. circumferentially and longitudinally, which then were compared with each other. The comparison between stiffness and elasticity of these veins showed that Saphenous vein’s stiffness is much higher than that of umbilical vein and also, it is less stretchable. Furthermore, for both vessels, longitudinal stiffness was higher than that of circumferential and in stark contrast, stretch ratio in circumferential direction came much higher than longitudinal orientation. Conclusion Blood pressure is very high in the region of aorta, so there should be a stiff blood vessel in this area and previous investigations showed that stiffer vessels would have a better influence on the flow of bypass. To this end, the current study has made an attempt to compare these two blood vessels’ stiffness, finding that Saphenous vein is stiffer than umbilical vein which is somehow as stiff as

  10. Thermographic visualization of the superficial vein and extravasation using the temperature gradient produced by the injected materials

    Science.gov (United States)

    Nakamura, Katsumasa; Sasaki, Tomonari; Ohga, Saiji; Yoshitake, Tadamasa; Terashima, Kotaro; Asai, Kaori; Matsumoto, Keiji; Shinoto, Makoto; Shioyama, Yoshiyuki; Nishie, Akihoro; Honda, Hiroshi

    2014-11-01

    There are few effective methods to detect or prevent the extravasation of injected materials such as chemotherapeutic agents and radiographic contrast materials. To investigate whether a thermographic camera could visualize the superficial vein and extravasation using the temperature gradient produced by the injected materials, an infrared thermographic camera with a high resolution of 0.04 °C was used. At the room temperature of 26 °C, thermal images and the time course of the temperature changes of a paraffin phantom embedded with rubber tubes (diameter 3.2 mm, wall thickness 0.8 mm) were evaluated after the tubes were filled with water at 15 °C or 25 °C. The rubber tubes were embedded at depths of 0 mm, 1.5 mm, and 3.0 mm from the surface of the phantom. Temperature changes were visualized in the areas of the phantom where the tubes were embedded. In general, changes were more clearly detected when greater temperature differences between the phantom and the water and shallower tube locations were employed. The temperature changes of the surface of a volunteer's arm were also examined after a bolus injection of physiological saline into the dorsal hand vein or the subcutaneous space. The injection of 5 ml room-temperature (26 °C) saline into the dorsal hand vein enabled the visualization of the vein. When 3 ml of room-temperature saline was injected through the vein into the subcutaneous space, extravasation was detected without any visualization of the vein. The subtraction image before and after the injection clearly showed the temperature changes induced by the saline. Thermography may thus be useful as a monitoring system to detect extravasation of the injected materials.

  11. Clean Hands Count

    Medline Plus

    Full Text Available ... myths and misperceptions about hand hygiene and empower patients to play a role in their care by ... Copyright Creators Advertise Developers +YouTube Terms Privacy Policy & Safety Send feedback Test new features Loading... Working... Sign ...

  12. Clean Hands Count

    Medline Plus

    Full Text Available ... Clean Hands Count Centers for Disease Control and Prevention (CDC) Loading... Unsubscribe from Centers for Disease Control and Prevention (CDC)? Cancel Unsubscribe Working... Subscribe Subscribed Unsubscribe 65K ...

  13. Clean Hands Count

    Medline Plus

    Full Text Available ... Clean Hands Count Centers for Disease Control and Prevention (CDC) Loading... Unsubscribe from Centers for Disease Control and Prevention (CDC)? Cancel Unsubscribe Working... Subscribe Subscribed Unsubscribe 66K ...

  14. Tropical Diabetic Hand Syndrome

    African Journals Online (AJOL)

    2015 Annals of Medical and Health Sciences Research | Published by Wolters Kluwer - Medknow. 473. Introduction ... diabetes.[2,3] Tropical diabetic hand syndrome is a terminology .... the importance of seeking medical attention immediately.

  15. Clean Hands Count

    Medline Plus

    Full Text Available ... now. Please try again later. Published on May 5, 2017 This video for healthcare providers is intended ... 36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 413,702 views 5:46 ...

  16. Clean Hands Count

    Medline Plus

    Full Text Available ... reminding healthcare providers to clean their hands. See: https://www.cdc.gov/handhygiene/campa... . Comments on this ... are allowed in accordance with our comment policy: http://www.cdc.gov/SocialMedia/Tools/... This video can ...

  17. Clean Hands Count

    Medline Plus

    Full Text Available ... empower patients to play a role in their care by asking or reminding healthcare providers to clean ... It's in your hands - prevent sepsis in health care' A 5 May 2018 advocacy message from WHO - ...

  18. Clean Hands Count

    Medline Plus

    Full Text Available ... why Close Clean Hands Count Centers for Disease Control and Prevention (CDC) Loading... Unsubscribe from Centers for Disease Control and Prevention (CDC)? Cancel Unsubscribe Working... Subscribe Subscribed ...

  19. Clean Hands Count

    Medline Plus

    Full Text Available ... has been rented. This feature is not available right now. Please try again later. Published on May ... Wash your Hands - it just makes sense. - Duration: 1:36. Seema Marwaha 404,414 views 1:36 ...

  20. Clean Hands Count

    Medline Plus

    Full Text Available ... Washing Video from CDC called "Put Your Hands Together" - Duration: 3:40. Patrick Boshell 27,834 views ... Policy & Safety Send feedback Test new features Loading... Working... Sign in to add this to Watch Later ...

  1. Clean Hands Count

    Medline Plus

    Full Text Available ... Published on May 5, 2017 This video for healthcare providers is intended to promote or encourage adherence ... role in their care by asking or reminding healthcare providers to clean their hands. See: https://www. ...

  2. A double toe-to-hand transfer in a young girl

    International Nuclear Information System (INIS)

    Rahman, M.F.

    2013-01-01

    A 14 years old girl lost all the fingers of her right hand except the thumb in a Toka (fodder chopping machine) 4 months ago. The fingers had been amputated at the level of the metacarpophalangeal joint. A double toe transfer was done using the second and third toes of her right foot to reconstruct the second and third digits of her right hand using microvascular technique. Bones were fixed with K-wires, corresponding tendons and nerves were attached, the dorsalis pedis artery was anastamosed end-to-side to the radial artery and the vein was anastamosed to the cephalic vein. The patient recovered well. K-wires were removed at 6 weeks and physiotherapy was started. After 4 months, the patient was able to use the hand for normal hand function and could make a tripod pinch. (author)

  3. Efficient Interaction Recognition through Positive Action Representation

    Directory of Open Access Journals (Sweden)

    Tao Hu

    2013-01-01

    Full Text Available This paper proposes a novel approach to decompose two-person interaction into a Positive Action and a Negative Action for more efficient behavior recognition. A Positive Action plays the decisive role in a two-person exchange. Thus, interaction recognition can be simplified to Positive Action-based recognition, focusing on an action representation of just one person. Recently, a new depth sensor has become widely available, the Microsoft Kinect camera, which provides RGB-D data with 3D spatial information for quantitative analysis. However, there are few publicly accessible test datasets using this camera, to assess two-person interaction recognition approaches. Therefore, we created a new dataset with six types of complex human interactions (i.e., named K3HI, including kicking, pointing, punching, pushing, exchanging an object, and shaking hands. Three types of features were extracted for each Positive Action: joint, plane, and velocity features. We used continuous Hidden Markov Models (HMMs to evaluate the Positive Action-based interaction recognition method and the traditional two-person interaction recognition approach with our test dataset. Experimental results showed that the proposed recognition technique is more accurate than the traditional method, shortens the sample training time, and therefore achieves comprehensive superiority.

  4. Absence of Middle Hepatic Vein Combined with Retro-Aortic Left Renal Vein: a Very Rare Case Report

    Directory of Open Access Journals (Sweden)

    Sezer Akçer

    2012-06-01

    Full Text Available The hepatic and renal veins drain into the inferior vena cava. The upper group of hepatic veins consists of three veins which extend to the posterior face of the liver to join the inferior cava. The left renal vein passes anterior to the aorta just below the origin of the superior mesenteric artery. We detected a variation in the hepatic and renal veins in a multislice CT angiogram of a nine-year-old male patient in the Radiology Department of Afyon Kocatepe University Medical School. The upper group hepatic veins normally drains into the inferior vena cava as three separate trunks, namely the right, left and middle. In our case, we found that only the right and left hepatic veins existed and the middle hepatic vein was absent. Furthermore, the left renal vein, which normally passes anterior to the abdominal aorta, was retro-aortic. Left renal vein variations are of great importance in planning retroperitoneal surgery and vascular interventions. Knowledge of a patient’s hepatic vein and renovascular anatomy and determining their variations and anomalies are of critical importance to abdominal operations, transplantations and preoperative evaluation of endovascular interventions.

  5. Invariant Face recognition Using Infrared Images

    International Nuclear Information System (INIS)

    Zahran, E.G.

    2012-01-01

    Over the past few decades, face recognition has become a rapidly growing research topic due to the increasing demands in many applications of our daily life such as airport surveillance, personal identification in law enforcement, surveillance systems, information safety, securing financial transactions, and computer security. The objective of this thesis is to develop a face recognition system capable of recognizing persons with a high recognition capability, low processing time, and under different illumination conditions, and different facial expressions. The thesis presents a study for the performance of the face recognition system using two techniques; the Principal Component Analysis (PCA), and the Zernike Moments (ZM). The performance of the recognition system is evaluated according to several aspects including the recognition rate, and the processing time. Face recognition systems that use visual images are sensitive to variations in the lighting conditions and facial expressions. The performance of these systems may be degraded under poor illumination conditions or for subjects of various skin colors. Several solutions have been proposed to overcome these limitations. One of these solutions is to work in the Infrared (IR) spectrum. IR images have been suggested as an alternative source of information for detection and recognition of faces, when there is little or no control over lighting conditions. This arises from the fact that these images are formed due to thermal emissions from skin, which is an intrinsic property because these emissions depend on the distribution of blood vessels under the skin. On the other hand IR face recognition systems still have limitations with temperature variations and recognition of persons wearing eye glasses. In this thesis we will fuse IR images with visible images to enhance the performance of face recognition systems. Images are fused using the wavelet transform. Simulation results show that the fusion of visible and

  6. Face Detection and Recognition

    National Research Council Canada - National Science Library

    Jain, Anil K

    2004-01-01

    This report describes research efforts towards developing algorithms for a robust face recognition system to overcome many of the limitations found in existing two-dimensional facial recognition systems...

  7. Recognizing the Operating Hand and the Hand-Changing Process for User Interface Adjustment on Smartphones.

    Science.gov (United States)

    Guo, Hansong; Huang, He; Huang, Liusheng; Sun, Yu-E

    2016-08-20

    As the size of smartphone touchscreens has become larger and larger in recent years, operability with a single hand is getting worse, especially for female users. We envision that user experience can be significantly improved if smartphones are able to recognize the current operating hand, detect the hand-changing process and then adjust the user interfaces subsequently. In this paper, we proposed, implemented and evaluated two novel systems. The first one leverages the user-generated touchscreen traces to recognize the current operating hand, and the second one utilizes the accelerometer and gyroscope data of all kinds of activities in the user's daily life to detect the hand-changing process. These two systems are based on two supervised classifiers constructed from a series of refined touchscreen trace, accelerometer and gyroscope features. As opposed to existing solutions that all require users to select the current operating hand or confirm the hand-changing process manually, our systems follow much more convenient and practical methods and allow users to change the operating hand frequently without any harm to the user experience. We conduct extensive experiments on Samsung Galaxy S4 smartphones, and the evaluation results demonstrate that our proposed systems can recognize the current operating hand and detect the hand-changing process with 94.1% and 93.9% precision and 94.1% and 93.7% True Positive Rates (TPR) respectively, when deciding with a single touchscreen trace or accelerometer-gyroscope data segment, and the False Positive Rates (FPR) are as low as 2.6% and 0.7% accordingly. These two systems can either work completely independently and achieve pretty high accuracies or work jointly to further improve the recognition accuracy.

  8. Recognizing the Operating Hand and the Hand-Changing Process for User Interface Adjustment on Smartphones

    Directory of Open Access Journals (Sweden)

    Hansong Guo

    2016-08-01

    Full Text Available As the size of smartphone touchscreens has become larger and larger in recent years, operability with a single hand is getting worse, especially for female users. We envision that user experience can be significantly improved if smartphones are able to recognize the current operating hand, detect the hand-changing process and then adjust the user interfaces subsequently. In this paper, we proposed, implemented and evaluated two novel systems. The first one leverages the user-generated touchscreen traces to recognize the current operating hand, and the second one utilizes the accelerometer and gyroscope data of all kinds of activities in the user’s daily life to detect the hand-changing process. These two systems are based on two supervised classifiers constructed from a series of refined touchscreen trace, accelerometer and gyroscope features. As opposed to existing solutions that all require users to select the current operating hand or confirm the hand-changing process manually, our systems follow much more convenient and practical methods and allow users to change the operating hand frequently without any harm to the user experience. We conduct extensive experiments on Samsung Galaxy S4 smartphones, and the evaluation results demonstrate that our proposed systems can recognize the current operating hand and detect the hand-changing process with 94.1% and 93.9% precision and 94.1% and 93.7% True Positive Rates (TPR respectively, when deciding with a single touchscreen trace or accelerometer-gyroscope data segment, and the False Positive Rates (FPR are as low as 2.6% and 0.7% accordingly. These two systems can either work completely independently and achieve pretty high accuracies or work jointly to further improve the recognition accuracy.

  9. Graphical symbol recognition

    OpenAIRE

    K.C. , Santosh; Wendling , Laurent

    2015-01-01

    International audience; The chapter focuses on one of the key issues in document image processing i.e., graphical symbol recognition. Graphical symbol recognition is a sub-field of a larger research domain: pattern recognition. The chapter covers several approaches (i.e., statistical, structural and syntactic) and specially designed symbol recognition techniques inspired by real-world industrial problems. It, in general, contains research problems, state-of-the-art methods that convey basic s...

  10. Quantification of deep medullary veins at 7 T brain MRI

    Energy Technology Data Exchange (ETDEWEB)

    Kuijf, Hugo J.; Viergever, Max A.; Vincken, Koen L. [University Medical Center Utrecht, Image Sciences Institute, Utrecht (Netherlands); Bouvy, Willem H.; Razoux Schultz, Tom B.; Biessels, Geert Jan [University Medical Center Utrecht, Department of Neurology, Brain Center Rudolf Magnus, Utrecht (Netherlands); Zwanenburg, Jaco J.M. [University Medical Center Utrecht, Image Sciences Institute, Utrecht (Netherlands); University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands)

    2016-10-15

    Deep medullary veins support the venous drainage of the brain and may display abnormalities in the context of different cerebrovascular diseases. We present and evaluate a method to automatically detect and quantify deep medullary veins at 7 T. Five participants were scanned twice, to assess the robustness and reproducibility of manual and automated vein detection. Additionally, the method was evaluated on 24 participants to demonstrate its application. Deep medullary veins were assessed within an automatically created region-of-interest around the lateral ventricles, defined such that all veins must intersect it. A combination of vesselness, tubular tracking, and hysteresis thresholding located individual veins, which were quantified by counting and computing (3-D) density maps. Visual assessment was time-consuming (2 h/scan), with an intra-/inter-observer agreement on absolute vein count of ICC = 0.76 and 0.60, respectively. The automated vein detection showed excellent inter-scan reproducibility before (ICC = 0.79) and after (ICC = 0.88) visually censoring false positives. It had a positive predictive value of 71.6 %. Imaging at 7 T allows visualization and quantification of deep medullary veins. The presented method offers fast and reliable automated assessment of deep medullary veins. (orig.)

  11. Hands of early primates.

    Science.gov (United States)

    Boyer, Doug M; Yapuncich, Gabriel S; Chester, Stephen G B; Bloch, Jonathan I; Godinot, Marc

    2013-12-01

    Questions surrounding the origin and early evolution of primates continue to be the subject of debate. Though anatomy of the skull and inferred dietary shifts are often the focus, detailed studies of postcrania and inferred locomotor capabilities can also provide crucial data that advance understanding of transitions in early primate evolution. In particular, the hand skeleton includes characteristics thought to reflect foraging, locomotion, and posture. Here we review what is known about the early evolution of primate hands from a comparative perspective that incorporates data from the fossil record. Additionally, we provide new comparative data and documentation of skeletal morphology for Paleogene plesiadapiforms, notharctines, cercamoniines, adapines, and omomyiforms. Finally, we discuss implications of these data for understanding locomotor transitions during the origin and early evolutionary history of primates. Known plesiadapiform species cannot be differentiated from extant primates based on either intrinsic hand proportions or hand-to-body size proportions. Nonetheless, the presence of claws and a different metacarpophalangeal [corrected] joint form in plesiadapiforms indicate different grasping mechanics. Notharctines and cercamoniines have intrinsic hand proportions with extremely elongated proximal phalanges and digit rays relative to metacarpals, resembling tarsiers and galagos. But their hand-to-body size proportions are typical of many extant primates (unlike those of tarsiers, and possibly Teilhardina, which have extremely large hands). Non-adapine adapiforms and omomyids exhibit additional carpal features suggesting more limited dorsiflexion, greater ulnar deviation, and a more habitually divergent pollex than observed plesiadapiforms. Together, features differentiating adapiforms and omomyiforms from plesiadapiforms indicate increased reliance on vertical prehensile-clinging and grasp-leaping, possibly in combination with predatory behaviors in

  12. Computed tomographic evaluation of the portal vein in the hepatomas

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kee Hyung; Lee, Seung Chul; Bae, Man Gil; Seo, Heung Suk; Kim, Soon Yong; Lee, Min Ho; Kee, Choon Suhk; Park, Kyung Nam [Hanyang University College of Medicine, Seoul (Korea, Republic of)

    1986-10-15

    Computed tomography and pornographic findings of 63 patients with hepatoma, undergone hepatic angiography and superior mesenteric pornography for evaluation of tumor and thrombosis of portal vein and determination of indication of transcatheter arterial embolization for palliative treatment of hepatoma from April, 85 to June, 86 in Hanyang university hospital, were reviewed. The results were as follows: 1. In 36 cases, portal vein thrombosis was detected during photography. Nineteen of 37 cases which revealed localized hepatoma in the right lobe of the liver showed portal vein thrombosis; 9 of 11 cases of the left lobe; 8 of 14 cases which were involved in entire liver revealed thrombosis. One case localized in the caudate lobe showed no evidence of invasion to portal vein. 2. Twenty-four of 34 cases with diffuse infiltrative hepatoma revealed portal vein thrombosis and the incidence of portal vein thrombosis in this type were higher than in the cases of the nodular type. 3. The portal vein thrombosis appeared as filling defects of low density in the lumen of the portal veins in CT and they did not reveal contrast enhancement. 4. CT revealed well the evidence of obstructions in the cases of portal vein thrombosis and the findings were well-corresponded to the findings of the superior mesenteric photography. 5. Five of the cases of the portal vein thrombosis were missed in the CT and the causes were considered as due to partial volume effect of enhanced portal vein with partial occlusion or arterioportal shunts. 6. Six of 13 cases with occlusion of main portal vein showed cavernous transformation and they were noted as multiple small enhanced vascularities around the porta hepatis in the CT. According to the results, we conclude that CT is a useful modality to detect the changes of the portal veins in the patients of the hepatoma.

  13. Computed tomographic evaluation of the portal vein in the hepatomas

    International Nuclear Information System (INIS)

    Lee, Kee Hyung; Lee, Seung Chul; Bae, Man Gil; Seo, Heung Suk; Kim, Soon Yong; Lee, Min Ho; Kee, Choon Suhk; Park, Kyung Nam

    1986-01-01

    Computed tomography and pornographic findings of 63 patients with hepatoma, undergone hepatic angiography and superior mesenteric pornography for evaluation of tumor and thrombosis of portal vein and determination of indication of transcatheter arterial embolization for palliative treatment of hepatoma from April, 85 to June, 86 in Hanyang university hospital, were reviewed. The results were as follows: 1. In 36 cases, portal vein thrombosis was detected during photography. Nineteen of 37 cases which revealed localized hepatoma in the right lobe of the liver showed portal vein thrombosis; 9 of 11 cases of the left lobe; 8 of 14 cases which were involved in entire liver revealed thrombosis. One case localized in the caudate lobe showed no evidence of invasion to portal vein. 2. Twenty-four of 34 cases with diffuse infiltrative hepatoma revealed portal vein thrombosis and the incidence of portal vein thrombosis in this type were higher than in the cases of the nodular type. 3. The portal vein thrombosis appeared as filling defects of low density in the lumen of the portal veins in CT and they did not reveal contrast enhancement. 4. CT revealed well the evidence of obstructions in the cases of portal vein thrombosis and the findings were well-corresponded to the findings of the superior mesenteric photography. 5. Five of the cases of the portal vein thrombosis were missed in the CT and the causes were considered as due to partial volume effect of enhanced portal vein with partial occlusion or arterioportal shunts. 6. Six of 13 cases with occlusion of main portal vein showed cavernous transformation and they were noted as multiple small enhanced vascularities around the porta hepatis in the CT. According to the results, we conclude that CT is a useful modality to detect the changes of the portal veins in the patients of the hepatoma.

  14. Mesenteric vein thrombosis after percitaneous transhepatic portal vein catheterisation for the localisation of an insulinoma

    International Nuclear Information System (INIS)

    Luska, G.; Langer, H.E.; Le Blanc, S.; Medizinische Hochschule Hannover

    1984-01-01

    The authors report on a fatal mesenteric vein thrombosis following an uncomplicated percutaneous transhepatic portal vein catheterisation for the localisation of an insulinoma. Several hours after the procedure the patient developed an acute abdomen. An emergency laparotomy revealed a haemorrhagic infarct of the ileum. The resected specimen showed an acute phlebitis with fresh thrombus. The cause of the phlebothrombosis was thought to be intimal damage from high osmolar contrast medium. There was no evidence of damage due to the catheder, either on the phlebogram or pathologically. (orig.) [de

  15. Hand eczema: An update

    Directory of Open Access Journals (Sweden)

    Chembolli Lakshmi

    2012-01-01

    Full Text Available Eczema, the commonest disorders afflicting the hands, is also the commonest occupational skin disease (OSD. In the dermatology outpatient departments, only the severe cases are diagnosed since patients rarely report with early hand dermatitis. Mild forms are picked up only during occupational screening. Hand eczema (HE can evolve into a chronic condition with persistent disease even after avoiding contact with the incriminated allergen / irritant. The important risk factors for hand eczema are atopy (especially the presence of dermatitis, wet work, and contact allergy. The higher prevalence in women as compared to men in most studies is related to environmental factors and is mainly applicable to younger women in their twenties. Preventive measures play a very important role in therapy as they enable the affected individuals to retain their employment and livelihood. This article reviews established preventive and therapeutic options and newer drugs like alitretinoin in hand eczema with a mention on the etiology and morphology. Identifying the etiological factors is of paramount importance as avoiding or minimizing these factors play an important role in treatment.

  16. Hand Hygiene: When and How

    Science.gov (United States)

    Hand Hygiene When and How August 2009 How to handrub? How to handwash? RUB HANDS FOR HAND HYGIENE! WASH HANDS WHEN VISIBLY SOILED Duration of the ... its use. When? YOUR 5 MOMENTS FOR HAND HYGIENE 1 BEFORETOUCHINGA PATIENT 2 B P ECFLOER R ...

  17. Arabidopsis thaliana Ei-5: Minor Vein Architecture Adjustment Compensates for Low Vein Density in Support of Photosynthesis.

    Science.gov (United States)

    Stewart, Jared J; Polutchko, Stephanie K; Demmig-Adams, Barbara; Adams, William W

    2018-01-01

    An Arabidopsis thaliana accession with naturally low vein density, Eifel-5 (Ei-5), was compared to Columbia-0 (Col-0) with respect to rosette growth, foliar vein architecture, photosynthesis, and transpiration. In addition to having to a lower vein density, Ei-5 grew more slowly, with significantly lower rates of rosette expansion, but had similar capacities for photosynthetic oxygen evolution on a leaf area basis compared to Col-0. The individual foliar minor veins were larger in Ei-5, with a greater number of vascular cells per vein, compared to Col-0. This compensation for low vein density resulted in similar values for the product of vein density × phloem cell number per minor vein in Ei-5 and Col-0, which suggests a similar capacity for foliar sugar export to support similar photosynthetic capacities per unit leaf area. In contrast, the product of vein density × xylem cell number per minor vein was significantly greater in Ei-5 compared to Col-0, and was associated not only with a higher ratio of water-transporting tracheary elements versus sugar-transporting sieve elements but also significantly higher foliar transpiration rates per leaf area in Ei-5. In contrast, previous studies in other systems had reported higher ratios of tracheary to sieve elements and higher transpiration rate to be associated with higher - rather than lower - vein densities. The Ei-5 accession thus further underscores the plasticity of the foliar vasculature by illustrating an example where a higher ratio of tracheary to sieve elements is associated with a lower vein density. Establishment of the Ei-5 accession, with a low vein density but an apparent overcapacity for water flux through the foliar xylem network, may have been facilitated by a higher level of precipitation in its habitat of origin compared to that of the Col-0 accession.

  18. 3D Visual Sensing of the Human Hand for the Remote Operation of a Robotic Hand

    Directory of Open Access Journals (Sweden)

    Pablo Gil

    2014-02-01

    Full Text Available New low cost sensors and open free libraries for 3D image processing are making important advances in robot vision applications possible, such as three-dimensional object recognition, semantic mapping, navigation and localization of robots, human detection and/or gesture recognition for human-machine interaction. In this paper, a novel method for recognizing and tracking the fingers of a human hand is presented. This method is based on point clouds from range images captured by a RGBD sensor. It works in real time and it does not require visual marks, camera calibration or previous knowledge of the environment. Moreover, it works successfully even when multiple objects appear in the scene or when the ambient light is changed. Furthermore, this method was designed to develop a human interface to control domestic or industrial devices, remotely. In this paper, the method was tested by operating a robotic hand. Firstly, the human hand was recognized and the fingers were detected. Secondly, the movement of the fingers was analysed and mapped to be imitated by a robotic hand.

  19. Mineral vein dynamics modeling (FRACS). Phase 1

    Energy Technology Data Exchange (ETDEWEB)

    Urai, J.; Virgo, S.; Arndt, M. [RWTH Aachen (Germany). Geologie-Endogene Dynamik] [and others

    2013-07-15

    The Mineral Vein Dynamics Modeling group ''FRACS'' is a team of 7 research groups from the Universities of Mainz, Aachen, Tuebingen, Karlsruhe, Bayreuth, ETH Zuerich and Glasgow working on an understanding of the dynamic development of fracturing, fluid flow and fracture sealing. World-class field laboratories, especially carbonate sequences from the Oman Mountains are studied and classified. State of the art numerical programs are written, expanded and used to simulate the dynamic interaction of fracturing, flow and resealing and the results are compared with the natural examples. Newest analytical technologies including laser scanning, high resolution X-ray microtomography, fluid inclusion and isotope analysis are performed to understand and compare the results of simulations with natural examples. A new statistical program was developed to classify the natural fracture and vein systems and compare them with dynamic numerical simulations and analytical models. The results of the first project phase are extremely promising. Most of the numerical models have been developed up to the stage where they can be used to simulate the natural examples. The models allow a definition of the first proxies for high fluid pressure and tectonic stresses. It was found out that the Oman Mountains are a complex and very dynamic system that constantly fractures and reseals from the scale of small veins up to the scale of large normal and strike slip faults. The numerical simulations also indicate that the permeability of such systems is not a constant but that the system adjusts to the driving force, for ex-ample high fluid pressure. When the system reseals fast a fluctuating behavior can be observed in the models where the system constantly fractures and reseals, which is in accordance with the observation of the natural laboratory.

  20. Recognition and Toleration

    DEFF Research Database (Denmark)

    Lægaard, Sune

    2010-01-01

    Recognition and toleration are ways of relating to the diversity characteristic of multicultural societies. The article concerns the possible meanings of toleration and recognition, and the conflict that is often claimed to exist between these two approaches to diversity. Different forms...... or interpretations of recognition and toleration are considered, confusing and problematic uses of the terms are noted, and the compatibility of toleration and recognition is discussed. The article argues that there is a range of legitimate and importantly different conceptions of both toleration and recognition...

  1. Insights into the mechanics of en-échelon sigmoidal vein formation using ultra-high resolution photogrammetry and computed tomography

    Science.gov (United States)

    Thiele, Samuel T.; Micklethwaite, Steven; Bourke, Paul; Verrall, Michael; Kovesi, Peter

    2015-08-01

    Two novel techniques, photo based reconstruction (photogrammetry) and computed tomography (CT), are used to investigate the formation of an exceptional array of sigmoidal veins in a hand sample from Cape Liptrap, Southern Victoria, and to provide constraint on models for their development. The accuracies of the photogrammetric models were tested by comparison with a laser scan generated three dimensional (3D) model. The photogrammetric model was found to be accurate to at least 0.25 mm and substantially more detailed than the laser scan. A methodology was developed by which 3D structural measurements could be extracted from the photogrammetric model. This was augmented with the CT model which, through its capacity to elucidate internal structure, was used to constrain the geometry and linkage of structures within the rock volume. The photogrammetric and CT data were then combined with detailed photomicrographs to evaluate the evolution of the sigmoidal veins in the sample. The angle between the sigmoidal vein margins and an inferred shear zone, as well as the orientations of the crystal fibres, were found to imply a rotation of >27°. However coeval pressure solution seams and older veinlets in the rock bridges between the veins were only found to have rotated by ∼10°, an observation not easily explained using existing models for sigmoidal vein formation. A new model is proposed in which a significant component of sigmoidal vein geometry is due to localised dilation caused by slip on the pressure solution seams. The process involves strain partitioning onto pressure solution seams, which leads to exaggeration of sigmoidal vein geometries. If not accounted for, the apparent vein rotation due to slip partitioning introduces errors into calculations of simple shear and volume strain based on sigmoidal arrays of this type. Furthermore, the CT data demonstrated that in 3D the veins are continuous and channel-like, implying a far higher degree of connectivity and

  2. Interferon-induced central retinal vein thrombosis

    International Nuclear Information System (INIS)

    Nazir, L.; Husain, A.; Haroon, W.; Shaikh, M.I.; Mirza, S.A.; Khan, Z.

    2012-01-01

    A middle-aged lady presented with sudden onset of unilateral central retinal vein thrombosis after completing 6 months course of interferon and ribavirin for chronic hepatitis C infection. She had no risk factors and all her thrombophilia workup was normal, however, she was found to be dyslipidemic which may have contributed to atherosclerosis and predispose to thrombosis. Despite anticoagulation, her visual acuity deteriorated. This case illustrates the possibility of unpredictable visual complication of interferon. Frequent eye examination should be undertaken in patients having underlying risk factors like diabetes, hypertension or dyslipidemia undergoing interferon therapy. (author)

  3. Interferon-induced central retinal vein thrombosis

    Energy Technology Data Exchange (ETDEWEB)

    Nazir, L; Husain, A; Haroon, W; Shaikh, M I; Mirza, S A; Khan, Z

    2012-11-15

    A middle-aged lady presented with sudden onset of unilateral central retinal vein thrombosis after completing 6 months course of interferon and ribavirin for chronic hepatitis C infection. She had no risk factors and all her thrombophilia workup was normal, however, she was found to be dyslipidemic which may have contributed to atherosclerosis and predispose to thrombosis. Despite anticoagulation, her visual acuity deteriorated. This case illustrates the possibility of unpredictable visual complication of interferon. Frequent eye examination should be undertaken in patients having underlying risk factors like diabetes, hypertension or dyslipidemia undergoing interferon therapy. (author)

  4. Aneurysmal malformation of the extrahepatic portal vein: a case report

    International Nuclear Information System (INIS)

    Lee, Jeong Min; Kang, Sung Soo; Kim, Chong Soo; Han, Hyeun Young

    1999-01-01

    Aneurysmal malformation of the portal vein is a rare entity. To our knowledge, only scattered reports of portal vein aneurysms appear in the literature in English, and there is no previously published report in Korean. We describe a case exhibiting aneurysmal malformation of the extrahepatic portal vein at the hepatic hilum ; the findings demonstrated by ultrasound, CT and angiography are discussed, a review of previously described cases is included

  5. Left hand tactile agnosia after posterior callosal lesion.

    Science.gov (United States)

    Balsamo, Maddalena; Trojano, Luigi; Giamundo, Arcangelo; Grossi, Dario

    2008-09-01

    We report a patient with a hemorrhagic lesion encroaching upon the posterior third of the corpus callosum but sparing the splenium. She showed marked difficulties in recognizing objects and shapes perceived through her left hand, while she could appreciate elementary sensorial features of items tactually presented to the same hand flawlessly. This picture, corresponding to classical descriptions of unilateral associative tactile agnosia, was associated with finger agnosia of the left hand. This very unusual case report can be interpreted as an instance of disconnection syndrome, and allows a discussion of mechanisms involved in tactile object recognition.

  6. CT of portal vein tumor thrombosis. Usefulness of dynamic CT

    Energy Technology Data Exchange (ETDEWEB)

    Takemoto, Kazumasa; Inoue, Yuichi; Tanaka, Masahiro; Nemoto, Yutaka; Nakamura, Kenji [Osaka City Univ. (Japan). Faculty of Medicine

    1983-08-01

    We evaluated CT findings of portal vein tumor thrombosis in 16 hepatomas by plain, contrast and dynamic CT. Plain and contrast CT findings were an enlargement of the portal vein (81%), intraluminal low density area (63%). Dynamic CT enhanced the diagnostic capability of the tumor thrombus as a relatively low density area because of the marked enhancement of the portal vein. In addition, dynamic CT newly demonstrated hyperdense peripheral ring (35%) and arterio portal shunt (35%). It is advisable to select the scan level to include the portal vein when dynamic CT is performed in the patient of hepatocellular carcinoma.

  7. Radiation Retinopathy Associated with Central Retinal Vein Occlusion

    Institute of Scientific and Technical Information of China (English)

    Yan; Liu; FengWen

    2007-01-01

    Purpose: To report a case of radiation retinopathy associated with central retinal vein occlusion.Methods: The clinical features and fundus fluorescein angiography of this case were analyzed.Results: The patient had been treated with radiotherapy for her nasopharyngeal carcinoma, and presented with sudden visual loss in the left eye. The funduscopic examination and fluorescein angiography showed the features of radiation retinopathy in both eyes, and central retinal vein occlusion in the left eye.Conclusions: Radiation retinopathy can be associated with central retinal vein occlusion in the same eye, and it seems that the endothelial cell loss caused by radiation retinopathy may lead to retinal vein occlusion.

  8. Characterization of a porcine model of chronic superficial varicose veins.

    Science.gov (United States)

    Jones, Gregory T; Grant, Mark W; Thomson, Ian A; Hill, B Geraldine; van Rij, André M

    2009-06-01

    Previous animal models of venous disease, while inducing venous hypertension and valvular insufficiency, do not produce superficial varicose veins. In this study, we aimed to develop and characterize a pig-based model of superficial varicose veins. Right femoral arteriovenous fistulae (AVF) were surgically fashioned in young adult pigs. Animals were examined at postoperative times up to 15 weeks to determine the development of varicose veins and measurement of both blood pressure and flow velocities within the superficial thigh veins. Histology and vascular corrosion casts were used to characterize the resulting structural venous alterations. Porcine pathophysiological features were compared with those of human primary superficial varicose veins. Gross superficial varicosities developed over the ipsilateral medial thigh region after an initial lag period of 1-2 weeks. Veins demonstrated retrograde filling with valvular incompetence, and a moderate, non-pulsatile, venous hypertension, which was altered by changes in posture and Valsalva. Venous blood flow velocities were elevated to 15-30 cm/s in varicose veins. Structurally, pig varicose veins were enlarged, tortuous, had valvular degeneration, and regions of focal medial atrophy with or without overlying intimal thickening. The superficial varicose veins, which developed within this model, have a pathophysiology that is consistent with that observed in humans. The porcine femoral AVF model is proposed as a suitable experimental model to evaluate the pathobiology of superficial venous disease. It may also be suitable for the evaluation of treatment interventions including drug therapy.

  9. [Portal perfusion with right gastroepiploic vein flow in liver transplant].

    Science.gov (United States)

    Mendoza-Sánchez, Federico; Javier-Haro, Francisco; Mendoza-Medina, Diego Federico; González-Ojeda, Alejandro; Cortés-Lares, José Antonio; Fuentes-Orozco, Clotilde

    Liver transplantation in patients with liver cirrhosis, portal vein thrombosis, and cavernous transformation of the portal vein, is a complex procedure with high possibility of liver graft dysfunction. It is performed in 2-19% of all liver transplants, and has a significantly high mortality rate in the post-operative period. Other procedures to maintain portal perfusion have been described, however there are no reports of liver graft perfusion using right gastroepiploic vein. A 20 year-old female diagnosed with cryptogenic cirrhosis, with a Child-Pugh score of 7 points (class "B"), and MELD score of 14 points, with thrombosis and cavernous transformation of the portal vein, severe portal hypertension, splenomegaly, a history of upper gastrointestinal bleeding due to oesophageal varices, and left renal agenesis. The preoperative evaluation for liver transplantation was completed, and the right gastroepiploic vein of 1-cm diameter was observed draining to the infrahepatic inferior vena cava and right suprarenal vein. An orthotopic liver transplantation was performed from a non-living donor (deceased on January 30, 2005) using the Piggy-Back technique. Portal vein perfusion was maintained using the right gastroepiploic vein, and the outcome was satisfactory. The patient was discharged 13 days after surgery. Liver transplantation was performed satisfactorily, obtaining an acceptable outcome. In this case, the portal perfusion had adequate blood flow through the right gastroepiploic vein. Copyright © 2015 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  10. 8 CFR 1292.2 - Organizations qualified for recognition; requests for recognition; withdrawal of recognition...

    Science.gov (United States)

    2010-01-01

    ...; requests for recognition; withdrawal of recognition; accreditation of representatives; roster. 1292.2...; requests for recognition; withdrawal of recognition; accreditation of representatives; roster. (a) Qualifications of organizations. A non-profit religious, charitable, social service, or similar organization...

  11. Clean Hands Count

    Medline Plus

    Full Text Available ... CDC) 97,825 views 5:12 CDC Flu Education Video - Duration: 10:26. Nicole Shelton 213 views ... Infection Control Video - Duration: 20:55. Paramedical Services Education Page 4,735 views 20:55 Hand Washing ...

  12. Hand Eczema: Treatment options

    DEFF Research Database (Denmark)

    Lund, Tamara Theresia; Agner, Tove

    2017-01-01

    Hand eczema is a common disease, it affects young people, is often work-related, and the burden of the disease is significant for the individual as well as for society. Factors to be considered when choosing a treatment strategy are, among others, whether the eczema is acute or chronic, the sever...

  13. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 824 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 409,492 ...

  14. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 786 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 413,702 ...

  15. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 414 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson ...

  16. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 869 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  17. Wash Your Hands

    Centers for Disease Control (CDC) Podcasts

    2010-03-08

    This video shows kids how to properly wash their hands, one of the most important steps we can take to avoid getting sick and spreading germs to others.  Created: 3/8/2010 by Centers for Disease Control and Prevention (CDC).   Date Released: 3/8/2010.

  18. Clean Hands Count

    Medline Plus

    Full Text Available ... no cure tomorrow - Duration: 3:10. World Health Organization 75,585 views 3:10 Wash 'Em - Hand ... soap and water - Duration: 1:27. World Health Organization 224,180 views 1:27 The five moments ...

  19. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 460 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson ...

  20. Clean Hands Count

    Medline Plus

    Full Text Available ... action today; no cure tomorrow - Duration: 3:10. World Health Organization 75,362 views 3:10 Wash ' ... handwash? With soap and water - Duration: 1:27. World Health Organization 219,427 views 1:27 Hand ...

  1. Clean Hands Count

    Medline Plus

    Full Text Available ... action today; no cure tomorrow - Duration: 3:10. World Health Organization 74,478 views 3:10 Wash your Hands - ... handwash? With soap and water - Duration: 1:27. World Health Organization 215,487 views 1:27 Infection Control Video - ...

  2. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 741 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  3. Matching hand radiographs

    NARCIS (Netherlands)

    Kauffman, J.A.; Slump, Cornelis H.; Bernelot Moens, H.J.

    2005-01-01

    Biometric verification and identification methods of medical images can be used to find possible inconsistencies in patient records. Such methods may also be useful for forensic research. In this work we present a method for identifying patients by their hand radiographs. We use active appearance

  4. Clean Hands Count

    Medline Plus

    Full Text Available ... today; no cure tomorrow - Duration: 3:10. World Health Organization 72,885 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 views 5:46 'It's in your ...

  5. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 029 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 411,974 ...

  6. Clean Hands Count

    Medline Plus

    Full Text Available ... no cure tomorrow - Duration: 3:10. World Health Organization 78,256 views 3:10 Wash 'Em - Hand ... message from WHO - Duration: 10:07. World Health Organization 9,045 views 10:07 A very serious ...

  7. Hands-On Calculus

    Science.gov (United States)

    Sutherland, Melissa

    2006-01-01

    In this paper we discuss manipulatives and hands-on investigations for Calculus involving volume, arc length, and surface area to motivate and develop formulae which can then be verified using techniques of integration. Pre-service teachers in calculus courses using these activities experience a classroom in which active learning is encouraged and…

  8. Clean Hands Count

    Medline Plus

    Full Text Available ... action today; no cure tomorrow - Duration: 3:10. World Health Organization 78,256 views 3:10 Wash ... handwash? With soap and water - Duration: 1:27. World Health Organization 230,361 views 1:27 Hand ...

  9. Hands-on Humidity.

    Science.gov (United States)

    Pankiewicz, Philip R.

    1992-01-01

    Presents five hands-on activities that allow students to detect, measure, reduce, and eliminate moisture. Students make a humidity detector and a hygrometer, examine the effects of moisture on different substances, calculate the percent of water in a given food, and examine the absorption potential of different desiccants. (MDH)

  10. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 396 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson ...

  11. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 094 views 1:19 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 411,974 ...

  12. Clean Hands Count

    Medline Plus

    Full Text Available ... starting stop Loading... Watch Queue Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with ... ads? Get YouTube Red. Working... Not now Try it free Find out why Close Clean Hands Count ...

  13. Clean Hands Count

    Medline Plus

    Full Text Available ... today; no cure tomorrow - Duration: 3:10. World Health Organization 69,414 views 3:10 Hand Washing ... Video - Duration: 5:46. Thomas Jefferson University & Jefferson Health 408,436 views 5:46 83 videos Play ...

  14. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 319 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  15. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 585 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 413,097 ...

  16. Clean Hands Count

    Medline Plus

    Full Text Available ... 14. Lake Health 14,415 views 3:14 Safety Demo: The Importance of Hand Washing - Duration: 2: ... Copyright Creators Advertise Developers +YouTube Terms Privacy Policy & Safety Send feedback Test new features Loading... Working... Sign ...

  17. Clean Hands Count

    Medline Plus

    Full Text Available ... action today; no cure tomorrow - Duration: 3:10. World Health Organization 72,319 views 3:10 Wash 'Em - Hand ... handwash? With soap and water - Duration: 1:27. World Health Organization 205,878 views 1:27 Germ Smart - Wash ...

  18. Hands On Earth Science.

    Science.gov (United States)

    Weisgarber, Sherry L.; Van Doren, Lisa; Hackathorn, Merrianne; Hannibal, Joseph T.; Hansgen, Richard

    This publication is a collection of 13 hands-on activities that focus on earth science-related activities and involve students in learning about growing crystals, tectonics, fossils, rock and minerals, modeling Ohio geology, geologic time, determining true north, and constructing scale-models of the Earth-moon system. Each activity contains…

  19. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 384 views 1:19 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson ...

  20. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 285 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  1. Clean Hands Count

    Medline Plus

    Full Text Available ... Gorin 243,451 views 2:57 Hand Hygiene Dance - Duration: 3:15. mohd hafiz 34,146 views ... Language: English Location: United States Restricted Mode: Off History Help Loading... Loading... Loading... About Press Copyright Creators ...

  2. Clean Hands Count

    Medline Plus

    Full Text Available ... YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. Working... Not now Try ... Wash your Hands - it just makes sense. - Duration: 1:36. Seema Marwaha 400,493 views 1:36 ...

  3. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 033 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  4. Clean Hands Count

    Medline Plus

    Full Text Available ... Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson Health 408,436 views 5: ... Prevention (CDC) 97,277 views 5:12 Loading more suggestions... Show more Language: English Location: United States ...

  5. Hands-On Hydrology

    Science.gov (United States)

    Mathews, Catherine E.; Monroe, Louise Nelson

    2004-01-01

    A professional school and university collaboration enables elementary students and their teachers to explore hydrology concepts and realize the beneficial functions of wetlands. Hands-on experiences involve young students in determining water quality at field sites after laying the groundwork with activities related to the hydrologic cycle,…

  6. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 043 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 411,292 ...

  7. Clean Hands Count

    Medline Plus

    Full Text Available ... News 581,131 views 18:49 Just Good Music 24/7 ● Classic Live Radio classics. 1,406 ... 611,013 views 1:46 Hand hygiene FULL music video - Duration: 2:33. AlfredHealthTV 26,798 views ...

  8. Clean Hands Count

    Medline Plus

    Full Text Available ... 52 Hand Sanitizers and Soaps Put to the Test - Duration: 2:26. ABC News 42,006 views ... Developers +YouTube Terms Privacy Policy & Safety Send feedback Test new features Loading... Working... Sign in to add ...

  9. Vein Patch Closure Using Below the Knee Greater Saphenous Vein for Femoral Endarterectomy Procedures is Not Always a Safe Choice

    Directory of Open Access Journals (Sweden)

    M. Berner

    Full Text Available : Background: The complication of vein patch rupture is well described after carotid patch angioplasty; however, there is a paucity of data about the safety of vein patch closure in the setting of femoral endarterectomy. Methods/results: From May 2012 to May 2015, 115 femoral endarterectomies with patch closure were performed. A patch rupture occurred in three cases (2.6% with a mortality rate of 66% (2/3. In all cases the greater saphenous vein below the knee was used as patch material. Discussion/conclusion: Vein patches, particularly from small calibre veins, should be excluded in femoral endarterectomy procedures as they pose a substantial risk of rupture. Keywords: Angioplasty, Patch rupture, Femoral artery, Patch, Great saphenous vein

  10. Suitability of Varicose Veins for Endovenous Treatments

    International Nuclear Information System (INIS)

    Goode, S. D.; Kuhan, G.; Altaf, N.; Simpson, R.; Beech, A.; Richards, T.; MacSweeney, S. T.; Braithwaite, B. D.

    2009-01-01

    The aim of the study was to assess the suitability of radiofrequency ablation (RFA), endovenous laser ablation (EVLA), and foam sclerotherapy (FS) for patients with symptomatic varicose veins (VVs). The study comprised 403 consecutive patients with symptomatic VVs. Data on 577 legs from 403 consecutive patients with symptomatic VVs were collected for the year 2006. Median patient age was 55 years (interquartile range 45-66), and 62% patients were women. A set of criteria based on duplex ultrasonography was used to select patients for each procedure. Great saphenous vein (GSV) reflux was present in 77% (446 of 577) of legs. Overall, 328 (73%) of the legs were suitable for at least one of the endovenous options. Of the 114 legs with recurrent GSV reflux disease, 83 (73%) were suitable to receive endovenous therapy. Patients with increasing age were less likely to be suitable for endovenous therapy (P = 0.03). Seventy-three percent of patients with VVs caused by GSV incompetence are suitable for endovenous therapy.

  11. Percutaneous transhepatic portal vein stenting in a patient with benign non-transplant postoperative portal vein stenosis: A case report

    OpenAIRE

    Madhusudhan, KS; Agrawal, Nikhil; Srivastava, Deep N; Pal, Sujoy; Gupta, Arun K

    2013-01-01

    Extrahepatic portal vein stenosis is caused by a variety of benign and malignant diseases and results in development of symptoms due to portal hypertension. Benign post-surgical adhesions causing portal vein stenosis in non-transplant population is an uncommon etiology of portal hypertension. Endovascular treatment of such patients with angioplasty and stenting is uncommonly reported in literature. We report a case of portal hypertension caused by benign postoperative portal vein fibrosis, su...

  12. Multimodal ultrasonographic assessment of leiomyosarcoma of the femoral vein in a patient misdiagnosed as having deep vein thrombosis

    Science.gov (United States)

    Zhang, Mei; Yan, Feng; Huang, Bin; Wu, Zhoupeng; Wen, Xiaorong

    2017-01-01

    Abstract Rationale: Primary leiomyosarcoma (LMS) of the vein is a rare tumor that arises from the smooth muscle cells of the vessel wall and has an extremely poor prognosis. This tumor can occur in vessels such as the inferior vena cava, great saphenous vein, femoral vein, iliac vein, popliteal vein, and renal vein; the inferior vena cava is the most common site. LMS of the femoral vein can result in edema and pain in the lower extremity; therefore, it is not easy to be differentiated from deep vein thrombosis (DVT). Moreover, virtually no studies have described the ultrasonographic features of LMS of the vein in detail. Patient concerns: We present a case of a 55-year-old woman with LMS of the left femoral vein that was misdiagnosed as having deep vein thrombosis (DVT) on initial ultrasonographic examination. The patient began to experience edema and pain in her left leg seven months previously. She was diagnosed as having DVT on initial ultrasonographic examination, but the DVT treatment that she had received for 7 months failed to improve the status of her left lower limb. Diagnoses: She subsequently underwent re-examination by means of a multimodal ultrasonographic imaging approach (regular B-mode imaging, color Doppler imaging, pulsed-wave Doppler imaging, contrast-enhanced ultrasonography), which confirmed a diagnosis of LMS. Interventions: This patient was treated successfully with surgery. Outcomes: This case demonstrates that use of multiple ultrasonographic imaging techniques can be helpful to diagnose LMS accurately. Detection of vasculature in a dilated vein filled with a heterogeneous hypoechoic substance on ultrasonography is a sign of a tumor. Lessons: The pitfall of misdiagnosing this tumor as DVT is a useful reminder. PMID:29145269

  13. The biometric recognition on contactless multi-spectrum finger images

    Science.gov (United States)

    Kang, Wenxiong; Chen, Xiaopeng; Wu, Qiuxia

    2015-01-01

    This paper presents a novel multimodal biometric system based on contactless multi-spectrum finger images, which aims to deal with the limitations of unimodal biometrics. The chief merits of the system are the richness of the permissible texture and the ease of data access. We constructed a multi-spectrum instrument to simultaneously acquire three different types of biometrics from a finger: contactless fingerprint, finger vein, and knuckleprint. On the basis of the samples with these characteristics, a moderate database was built for the evaluation of our system. Considering the real-time requirements and the respective characteristics of the three biometrics, the block local binary patterns algorithm was used to extract features and match for the fingerprints and finger veins, while the Oriented FAST and Rotated BRIEF algorithm was applied for knuckleprints. Finally, score-level fusion was performed on the matching results from the aforementioned three types of biometrics. The experiments showed that our proposed multimodal biometric recognition system achieves an equal error rate of 0.109%, which is 88.9%, 94.6%, and 89.7% lower than the individual fingerprint, knuckleprint, and finger vein recognitions, respectively. Nevertheless, our proposed system also satisfies the real-time requirements of the applications.

  14. More than two HANDs to tango.

    Science.gov (United States)

    Kolson, Dennis; Buch, Shilpa

    2013-12-01

    Developing a validated tool for the rapid and efficient assessment of cognitive functioning in HIV-infected patients in a typical outpatient clinical setting has been an unmet goal of HIV research since the recognition of the syndrome of HIV-associated dementia (HAD) nearly 20 years ago. In this issue of JNIP Cross et al. report the application of the International HIV Dementia Scale (IHDS) in a U.S.-based urban outpatient clinic to evaluate its utility as a substitute for the more time- and effort-demanding formalized testing criteria known as the Frascati criteria that was developed in 2007 to define the syndrome of HIV-associated neurocognitive disorders (HAND). In this study an unselected cohort of 507 individuals (68 % African American) that were assessed using the IHDS in a cross-sectional study revealed a 41 % prevalence of cognitive impairment (labeled ‘symptomatic HAND’) that was associated with African American race, older age, unemployment, education level, and depression. While the associations between cognitive impairment and older age, education, unemployment status and depression in HIV-infected patients are not surprising, the association with African American ancestry and cognitive impairment in the setting of HIV infection is a novel finding of this study. This commentary discusses several important issues raised by the study, including the pitfalls of assessing cognitive functioning with rapid screening tools, cognitive testing criteria, normative testing control groups, accounting for HAND co-morbidity factors, considerations for clinical trials assessing HAND, and selective population vulnerability to HAND.

  15. Optical Pattern Recognition

    Science.gov (United States)

    Yu, Francis T. S.; Jutamulia, Suganda

    2008-10-01

    Contributors; Preface; 1. Pattern recognition with optics Francis T. S. Yu and Don A. Gregory; 2. Hybrid neural networks for nonlinear pattern recognition Taiwei Lu; 3. Wavelets, optics, and pattern recognition Yao Li and Yunglong Sheng; 4. Applications of the fractional Fourier transform to optical pattern recognition David Mendlovic, Zeev Zalesky and Haldum M. Oxaktas; 5. Optical implementation of mathematical morphology Tien-Hsin Chao; 6. Nonlinear optical correlators with improved discrimination capability for object location and recognition Leonid P. Yaroslavsky; 7. Distortion-invariant quadratic filters Gregory Gheen; 8. Composite filter synthesis as applied to pattern recognition Shizhou Yin and Guowen Lu; 9. Iterative procedures in electro-optical pattern recognition Joseph Shamir; 10. Optoelectronic hybrid system for three-dimensional object pattern recognition Guoguang Mu, Mingzhe Lu and Ying Sun; 11. Applications of photrefractive devices in optical pattern recognition Ziangyang Yang; 12. Optical pattern recognition with microlasers Eung-Gi Paek; 13. Optical properties and applications of bacteriorhodopsin Q. Wang Song and Yu-He Zhang; 14. Liquid-crystal spatial light modulators Aris Tanone and Suganda Jutamulia; 15. Representations of fully complex functions on real-time spatial light modulators Robert W. Cohn and Laurence G. Hassbrook; Index.

  16. Linguistic approach to object recognition by grasping

    Energy Technology Data Exchange (ETDEWEB)

    Marik, V

    1982-01-01

    A method for recognizing both the three-dimensional object shapes and their sizes by grasping them with an antropomorphic five-finger artificial hand is described. The hand is equipped with position sensing elements in the joints of the fingers and with a tactile transducer net on the palm surface. The linguistic method uses formal grammars and languages for the pattern description. The recognition is hierarchically arranged, every level being different from the others by a formal language which has been used. On every level the pattern description is generated and verified from the symmetrical and semantical points of view. The results of the implementation of the recognition of cones, pyramides, spheres, prisms and cylinders are presented and discussed. 8 references.

  17. Diagnostic value of color doppler ultrasonography in detecting stenosis and occlusion of central veins in patients with chronic kidney disease

    Directory of Open Access Journals (Sweden)

    Masoud Pezeshki Rad

    2015-01-01

    Full Text Available Venography is an invasive diagnostic test that uses contrast material that provides a picture of the condition of the veins. But, complications, including adverse effects on the kidney, do occur. On the other hand, with the current technological development, application of ultrasound in the diagnosis of obstructive diseases of the veins is gaining popularity, being non-invasive, easy to perform and cost-effective. The aim of this study was to evaluate the diagnostic value of Doppler sonography in the diagnosis of central vein stenosis. In this descriptive-analytical study, 41 hemodialysis patients who had been referred for 50 upper limb venographies to the radiology department of Imam Reza (AS were included. Patients with chronic kidney disease with a history of catheterization of the vein, jugular or subclavian, and who had established fistulas or synthetic vascular grafts were targeted. Central venous ultrasound was performed on both sides to evaluate stenosis or occlusion. Venography was performed by the radiologist the next day or the day before hemodialysis. Data on demographic characteristics, findings of clinical examination and findings of ultrasound as well as venography were recorded by using the SPSS software, Chi-square test and Spearman correlation, and Kappa agreement was calculated for sensitivity, specificity and predictive values. Twenty-three (56% patients were male subjects and 18 patients (44% were female. Twenty-three (56% patients of the study population were aged 60 years. The overall sensitivity, specificity and positive predictive value and negative predictive value of Doppler sonography in the proximal veins in hemodialysis patients compared with venography were, respectively, 80.9%, 79.3%, 73.9% and 85.1%. Color Doppler sonography, as a non-invasive method, could be a good alternative for venography in the assessment of the upper limb with central vein stenosis and occlusion.

  18. Diagnostic value of color doppler ultrasonography in detecting stenosis and occlusion of central veins in patients with chronic kidney disease.

    Science.gov (United States)

    Rad, Masoud Pezeshki; Kazemzadeh, Gholam Hosain; Ziaee, Masood; Azarkar, Ghodsieh

    2015-03-01

    Venography is an invasive diagnostic test that uses contrast material that provides a picture of the condition of the veins. But, complications, including adverse effects on the kidney, do occur. On the other hand, with the current technological development, application of ultrasound in the diagnosis of obstructive diseases of the veins is gaining popularity, being non-invasive, easy to perform and cost-effective. The aim of this study was to evaluate the diagnostic value of Doppler sonography in the diagnosis of central vein stenosis. In this descriptive-analytical study, 41 hemodialysis patients who had been referred for 50 upper limb venographies to the radiology department of Imam Reza (AS) were included. Patients with chronic kidney disease with a history of catheterization of the vein, jugular or subclavian, and who had established fistulas or synthetic vascular grafts were targeted. Central venous ultrasound was performed on both sides to evaluate stenosis or occlusion. Venography was performed by the radiologist the next day or the day before hemodialysis. Data on demographic characteristics, findings of clinical examination and findings of ultrasound as well as venography were recorded by using the SPSS software, Chi-square test and Spearman correlation, and Kappa agreement was calculated for sensitivity, specificity and predictive values. Twenty-three (56%) patients were male subjects and 18 patients (44%) were female. Twenty-three (56%) patients of the study population were aged 60 years. The overall sensitivity, specificity and positive predictive value and negative predictive value of Doppler sonography in the proximal veins in hemodialysis patients compared with venography were, respectively, 80.9%, 79.3%, 73.9% and 85.1%. Color Doppler sonography, as a non-invasive method, could be a good alternative for venography in the assessment of the upper limb with central vein stenosis and occlusion.

  19. Pattern recognition & machine learning

    CERN Document Server

    Anzai, Y

    1992-01-01

    This is the first text to provide a unified and self-contained introduction to visual pattern recognition and machine learning. It is useful as a general introduction to artifical intelligence and knowledge engineering, and no previous knowledge of pattern recognition or machine learning is necessary. Basic for various pattern recognition and machine learning methods. Translated from Japanese, the book also features chapter exercises, keywords, and summaries.

  20. Compact Dexterous Robotic Hand

    Science.gov (United States)

    Lovchik, Christopher Scott (Inventor); Diftler, Myron A. (Inventor)

    2001-01-01

    A compact robotic hand includes a palm housing, a wrist section, and a forearm section. The palm housing supports a plurality of fingers and one or more movable palm members that cooperate with the fingers to grasp and/or release an object. Each flexible finger comprises a plurality of hingedly connected segments, including a proximal segment pivotally connected to the palm housing. The proximal finger segment includes at least one groove defining first and second cam surfaces for engagement with a cable. A plurality of lead screw assemblies each carried by the palm housing are supplied with power from a flexible shaft rotated by an actuator and output linear motion to a cable move a finger. The cable is secured within a respective groove and enables each finger to move between an opened and closed position. A decoupling assembly pivotally connected to a proximal finger segment enables a cable connected thereto to control movement of an intermediate and distal finger segment independent of movement of the proximal finger segment. The dexterous robotic hand closely resembles the function of a human hand yet is light weight and capable of grasping both heavy and light objects with a high degree of precision.

  1. Arthritis of the hand - Rheumatoid

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is a Hand Surgeon? What is a Hand Therapist? Media Find a Hand Surgeon Home Anatomy Rheumatoid Arthritis Email to a friend * required fields ...

  2. Statistical Pattern Recognition

    CERN Document Server

    Webb, Andrew R

    2011-01-01

    Statistical pattern recognition relates to the use of statistical techniques for analysing data measurements in order to extract information and make justified decisions.  It is a very active area of study and research, which has seen many advances in recent years. Applications such as data mining, web searching, multimedia data retrieval, face recognition, and cursive handwriting recognition, all require robust and efficient pattern recognition techniques. This third edition provides an introduction to statistical pattern theory and techniques, with material drawn from a wide range of fields,

  3. Sciatica caused by a dilated epidural vein: MR findings

    International Nuclear Information System (INIS)

    Demaerel, P.; Petre, C.; Wilms, G.; Plets, C.

    1999-01-01

    We report the MR imaging findings in a 41-year-old woman presenting with sudden low back pain and sciatica. At surgery a dilated epidural vein was found compressing the nerve root. The MR findings may suggest the diagnosis. Magnetic resonance imaging of a dilated epidural vein or varix causing sciatica has not been reported until now. (orig.) (orig.)

  4. Endovascular management for significant iatrogenic portal vein bleeding.

    Science.gov (United States)

    Kim, Jong Woo; Shin, Ji Hoon; Park, Jonathan K; Yoon, Hyun-Ki; Ko, Gi-Young; Gwon, Dong Il; Kim, Jin Hyoung; Sung, Kyu-Bo

    2017-11-01

    Background Despite conservative treatment, hemorrhage from an intrahepatic branch of the portal vein can cause hemodynamic instability requiring urgent intervention. Purpose To retrospectively report the outcomes of hemodynamically significant portal vein bleeding after endovascular management. Material and Methods During a period of 15 years, four patients (2 men, 2 women; median age, 70.5 years) underwent angiography and embolization for iatrogenic portal vein bleeding. Causes of hemorrhage, angiographic findings, endovascular treatment, and complications were reported. Results Portal vein bleeding occurred after percutaneous liver biopsy (n = 2), percutaneous radiofrequency ablation (n = 1), and percutaneous cholecystostomy (n = 1). The median time interval between angiography and percutaneous procedure was 5 h (range, 4-240 h). Common hepatic angiograms including indirect mesenteric portograms showed active portal vein bleeding into the peritoneal cavity with (n = 1) or without (n = 2) an arterioportal (AP) fistula, and portal vein pseudoaneurysm alone with an AP fistula (n = 1). Successful transcatheter arterial embolization (n = 2) or percutaneous transhepatic portal vein embolization (n = 2) was performed. Embolic materials were n-butyl cyanoacrylate alone (n = 2) or in combination with gelatin sponge particles and coils (n = 2). There were no major treatment-related complications or patient mortality within 30 days. Conclusion Patients with symptomatic or life-threatening portal vein bleeding following liver-penetrating procedures can successfully be managed with embolization.

  5. A Modified Technique of Basilic Vein Transposition for Haemodialysis

    International Nuclear Information System (INIS)

    Chaudhary, F. A.; Parvez, Z.

    2014-01-01

    Objective: To modify the technique of basilic vein transposition for vascular accesss for haemodialysis aiming at better maturation rate, longer survival of fistula and lesser complications. Study Design: Case series. Place and Duration of Study: Shaikh Zayed Hospital and Omer Hospital, Lahore, from February 2008 to July 2011. Methodology: Patients referred for basilic vein transposition for haemodialysis vascular access were prospectively enrolled. The surgical technique included small tracking incisions, an extra 3 - 4 cm of vein length harvesting to avoid tension in the vein in its new course, an oval arteriotomy and a smooth curved pathway, away from vein harvesting incision to avoid entrapment of vein in the scar. Maturation rate, fistula survival and other complications were noted. Results: There was no immediate failure in 51 patients. The complications during follow-up period were infection and thrombosis, bleeding and non-development of basilic vein in 2 patients each; and false aneurysm formation in one. Four patients died during follow-up period. The maturation time was 4.9 A +- 1.1 weeks. The early patency rate was 92.2%, same at 6 months and 90.7% at 12 months. Conclusion: Arteriovenous fistula constructed with modified technique of basilic vein transposition is an acceptable and valid option of vascular access for haemodialysis. (author)

  6. A study of images of Projective Angles of pulmonary veins

    Energy Technology Data Exchange (ETDEWEB)

    Wang Jue [Beijing Anzhen Hospital, Beijing (China); Zhaoqi, Zhang [Beijing Anzhen Hospital, Beijing (China)], E-mail: zhaoqi5000@vip.sohu.com; Yu Wei; Miao Cuilian; Yan Zixu; Zhao Yike [Beijing Anzhen Hospital, Beijing (China)

    2009-09-15

    Aims: In images of magnetic resonance and computed tomography (CT) there are visible angles between pulmonary veins and the coronary, transversal or sagittal section of body. In this study these angles are measured and defined as Projective Angles of pulmonary veins. Several possible influential factors and characters of distribution are studied and analyzed for a better understanding of this imaging anatomic character of pulmonary veins. And it could be the anatomic base of adjusting correctly the angle of the central X-ray of the angiography of pulmonary veins undergoing the catheter ablation of atrial fibrillation (AF). Method: Images of contrast enhanced magnetic resonance angiography (CEMRA) and contrast enhanced computer tomography (CECT) of the left atrium and pulmonary veins of 137 health objects and patients with atrial fibrillation (AF) are processed with the technique of post-processing, and Projective Angles to the coronary and transversal sections are measured and analyzed statistically. Result: Project Angles of pulmonary veins are one of real and steady imaging anatomic characteristics of pulmonary veins. The statistical distribution of variables is relatively concentrated, with a fairly good representation of average value. It is possible to improve the angle of the central X-ray according to the average value in the selective angiography of pulmonary veins undergoing the catheter ablation of AF.

  7. The Short Saphenous Vein: A Viable Alternative Conduit for ...

    African Journals Online (AJOL)

    This novel position allowed for two members of the surgical team to operate at the same time, thus ... along the ultrasound-marked vein positions similar to when harvesting the LSV. Once the veins were harvested and ... occlusion compared to LSV grafts utilized in the same procedure,[8] it was brought back to prominence ...

  8. A Tight Spot After Pulmonary Vein Catheter Ablation

    NARCIS (Netherlands)

    Amir, Rabia; Yeh, Lu; Montealegre-Gallegos, Mario; Saraf, Rabya; Matyal, Robina; Mahmood, Feroze

    2016-01-01

    A 52-YEAR-OLD woman with a history of embolic stroke due to paroxysmal atrial fibrillation was referred to the authors’ institution for epicardial surgical pulmonary vein isolation with left atrial appendage resection. The patient had 2 previous failed pulmonary vein catheter ablations. Dense

  9. Dorzolamide increases retinal oxygen tension after branch retinal vein occlusion

    DEFF Research Database (Denmark)

    Noergaard, Michael Hove; Bach-Holm, Daniella; Scherfig, Erik

    2008-01-01

    To study the effect of dorzolamide on the preretinal oxygen tension (RPO(2)) in retinal areas affected by experimental branch retinal vein occlusion (BRVO) in pigs.......To study the effect of dorzolamide on the preretinal oxygen tension (RPO(2)) in retinal areas affected by experimental branch retinal vein occlusion (BRVO) in pigs....

  10. Portal vein thrombosis after splenectomy for beta-thalassemia major

    International Nuclear Information System (INIS)

    Al-Hawsawi, Zakaria M.; Tarawah, Ahmed M.; Hassan, Ruhul Amin A.; Haouimi, Ammar S.

    2004-01-01

    Portal vein thrombosis is a recognized complication after splenectomy for beta-thalassemia major due to the chronic hypercoagulable state which has been recognized to exist in childhood thalassemia and contribute to thromboembolic events. We reporting one patient with beta-thalassemia major developed portal vein thrombosis following splenectomy. (author)

  11. Portal Vein Stenting for Portal Biliopathy with Jaundice

    Energy Technology Data Exchange (ETDEWEB)

    Hyun, Dongho, E-mail: mesentery@naver.com; Park, Kwang Bo, E-mail: kbjh.park@samsung.com [Sungkyunkwan University School of Medicine, Department of Radiology, Samsung Medical Center (Korea, Republic of); Lim, Seong Joo [Konyang University, Department of Radiology, College of Medicine, Konyang University Hospital (Korea, Republic of); Hwang, Jin Ho [Hallym University Sacred Heart Hospital, Department of Radiology (Korea, Republic of); Sinn, Dong Hyun [Sungkyunkwan University School of Medicine, Department of Medicine, Samsung Medical Center (Korea, Republic of)

    2016-04-15

    Portal biliopathy refers to obstruction of the bile duct by dilated peri- or para-ductal collateral channels following the main portal vein occlusion from various causes. Surgical shunt operation or endoscopic treatment has been reported. Herein, we report a case of portal biliopathy that was successfully treated by interventional portal vein recanalization.

  12. On the dragnosis of deep vein thrombosis

    International Nuclear Information System (INIS)

    Olsson, C.-G.

    1979-01-01

    Clinical and laboratory diagnostic methods were studied in 301 consecutive patients with suspected deep vein thrombosis (DVT). Unexpectedly, phlebography (the reference method) was found to cause DVT in estimated 48 % of patients without initial DVT. Using a new type of contrast medium, however, no thrombotic complications were found. - Neither clinical examination nor plethysmography were found to give reliable results. Using a modified technique for radioisotope detection, high sensitivity to DVT was found with the 125 I-fibrinogen uptake test (within 2 days) and a newly developed 99 Tcsup(m)-plasmin test (within one hour). Since both tests showed low specificity, they are reliable as screening tests to exclude DVT, but not as independent diagnostic methods. (author)

  13. Leiomyosarcoma of the great saphenous vein

    Directory of Open Access Journals (Sweden)

    Alexandre Campos Moraes Amato

    2015-06-01

    Full Text Available A 56-year-old male patient presented with a complaint of two painful, hard, palpable nodules in the right lower limb. A Doppler ultrasound scan revealed the presence of nodules, likely to be neoplastic. Computed angiography showed two solid hypervascular nodules in the right great saphenous vein, fed by branches of the posterior tibial artery. Embolization of the nodules using surgical cyanoacrylate was performed, followed by an excisional biopsy. Anatomical pathology and immunohistochemical analysis identified the nodule as a high-grade leiomyosarcoma, characterized by ten mitotic figures per ten high-power fields, necrosis and cell pleomorphism. Immunohistochemical analysis results were positive for caldesmon and desmin labeling. A second surgical procedure was performed to enlarge the free margins.

  14. Portal Vein Embolization: What Do We Know?

    Energy Technology Data Exchange (ETDEWEB)

    Denys, Alban, E-mail: Alban.Denys@chuv.ch [Centre Hospitalo Universitaire Vaudois, Department of Radiology and Interventional Radiology Unit (Switzerland); Prior, John [Centre Hospitalo Universitaire Vaudois, Department of Nuclear Medicine (Switzerland); Bize, Pierre; Duran, Rafael [Centre Hospitalo Universitaire Vaudois, Department of Radiology and Interventional Radiology Unit (Switzerland); Baere, Thierry De [Institut Gustave Roussy, Department of Interventional Radiology (France); Halkic, Nermin; Demartines, Nicolas [Centre Hospitalo Universitaire Vaudois, Department of Visceral Surgery (Switzerland)

    2012-10-15

    Portal vein embolization (PVE) has been developed to increase the size of the future remnant liver (FRL) left in place after major hepatectomy, thus reducing the risk of postoperative liver insufficiency. PVE consist in embolizing preoperatively portal branches of the segments that will be resected. Indication is based on preoperative measurements of the FRL by computed tomography and its ratio with either the theoretical liver volume or by direct measurement of the functional liver volume. After PVE, the volume and function of the FRL increases in 3 to 6 weeks, permitting extensive resections in patients otherwise contraindicated for liver resection. The PVE technique is variable from one center to another; however n-butyl-cyano-acrylate provides an interesting compromise between hypertrophy rate and procedure risk.

  15. Disastrous Portal Vein Embolization Turned into a Successful Intervention

    Energy Technology Data Exchange (ETDEWEB)

    Dobrocky, Tomas, E-mail: tomas.dobrocky@insel.ch [University of Bern, Department of Interventional, Pediatric and Diagnostic Radiology, Inselspital, University Hospital (Switzerland); Kettenbach, Joachim, E-mail: joachim.kettenbach@stpoelten.lknoe.at [Universitätsklinikum St. Pölten-Lilienfeld, Institute of Medical Radiology, Diagnostic, Intervention (Austria); Lopez-Benitez, Ruben, E-mail: Ruben.lopez@insel.ch; Kara, Levent, E-mail: levent.kara@insel.ch [University of Bern, Department of Interventional, Pediatric and Diagnostic Radiology, Inselspital, University Hospital (Switzerland)

    2015-10-15

    Portal vein embolization (PVE) may be performed before hemihepatectomy to increase the volume of future liver remnant (FLR) and to reduce the risk of postoperative liver insufficiency. We report the case of a 71-year-old patient with hilar cholangiocarcinoma undergoing PVE with access from the right portal vein using a mixture of n-butyl-2-cyanoacrylate and ethiodized oil. During the procedure, nontarget embolization of the left portal vein occurred. An aspiration maneuver of the polymerized plug failed; however, the embolus obstructing portal venous flow in the FLR was successfully relocated into the right portal vein while carefully bypassing the plug with a balloon catheter, inflating the balloon, and pulling the plug into the main right portal vein.

  16. Acute paraumbilical vein recanalization: an unusual complication of acute pancreatitis

    Directory of Open Access Journals (Sweden)

    R J Foster

    2015-04-01

    Full Text Available Acute pancreatitis is associated with a number of well-known complications and imaging findings. Spontaneous recanalization of the paraumbilical veins as a consequence of pancreatitis in a patient with an otherwise normal liver is, however, a rare entity. This case report depicts this unusual complication as a consequence of gallstone pancreatitis in a patient with a non-cirrhotic liver and no clinical or radiological evidence of portal hypertension. There was recanalization of the paraumbilical veins followed by thrombosis, which is believed to have propagated in a retrograde fashion into distal branches of the otherwise patent portal vein. A literature search for similar cases such as this has yielded no results. Although rare, clinicians and radiologists alike need to be aware of this finding. This case discussion highlights the embryology and anatomy of the paraumbilical veins, as well as discusses the management of paraumbilical and portal vein thrombosis.

  17. Mineral vein dynamics modelling (FRACS II)

    International Nuclear Information System (INIS)

    Urai, J.; Virgo, S.; Arndt, M.

    2016-08-01

    The Mineral Vein Dynamics Modeling group ''FRACS'' started out as a team of 7 research groups in its first phase and continued with a team of 5 research groups at the Universities of Aachen, Tuebingen, Karlsruhe, Mainz and Glasgow during its second phase ''FRACS 11''. The aim of the group was to develop an advanced understanding of the interplay between fracturing, fluid flow and fracture healing with a special emphasis on the comparison of field data and numerical models. Field areas comprised the Oman mountains in Oman (which where already studied in detail in the first phase), a siliciclastic sequence in the Internal Ligurian Units in Italy (closed to Sestri Levante) and cores of Zechstein carbonates from a Lean Gas reservoir in Northern Germany. Numerical models of fracturing, sealing and interaction with fluid that were developed in phase I where expanded in phase 11. They were used to model small scale fracture healing by crystal growth and the resulting influence on flow, medium scale fracture healing and its influence on successive fracturing and healing, as well as large scale dynamic fluid flow through opening and closing fractures and channels as a function of fluid overpressure. The numerical models were compared with structures in the field and we were able to identify first proxies for mechanical vein-hostrock properties and fluid overpressures versus tectonic stresses. Finally we propose a new classification of stylolites based on numerical models and observations in the Zechstein cores and continued to develop a new stress inversion tool to use stylolites to estimate depth of their formation.

  18. Mineral vein dynamics modelling (FRACS II)

    Energy Technology Data Exchange (ETDEWEB)

    Urai, J.; Virgo, S.; Arndt, M. [RWTH Aachen (Germany); and others

    2016-08-15

    The Mineral Vein Dynamics Modeling group ''FRACS'' started out as a team of 7 research groups in its first phase and continued with a team of 5 research groups at the Universities of Aachen, Tuebingen, Karlsruhe, Mainz and Glasgow during its second phase ''FRACS 11''. The aim of the group was to develop an advanced understanding of the interplay between fracturing, fluid flow and fracture healing with a special emphasis on the comparison of field data and numerical models. Field areas comprised the Oman mountains in Oman (which where already studied in detail in the first phase), a siliciclastic sequence in the Internal Ligurian Units in Italy (closed to Sestri Levante) and cores of Zechstein carbonates from a Lean Gas reservoir in Northern Germany. Numerical models of fracturing, sealing and interaction with fluid that were developed in phase I where expanded in phase 11. They were used to model small scale fracture healing by crystal growth and the resulting influence on flow, medium scale fracture healing and its influence on successive fracturing and healing, as well as large scale dynamic fluid flow through opening and closing fractures and channels as a function of fluid overpressure. The numerical models were compared with structures in the field and we were able to identify first proxies for mechanical vein-hostrock properties and fluid overpressures versus tectonic stresses. Finally we propose a new classification of stylolites based on numerical models and observations in the Zechstein cores and continued to develop a new stress inversion tool to use stylolites to estimate depth of their formation.

  19. Puerperal ovarian vein thrombosis: two case reports.

    Science.gov (United States)

    Angelini, Marta; Barillari, Giovanni; Londero, Ambrogio P; Bertozzi, Serena; Bernardi, Sergio; Petri, Roberto; Driul, Lorenza; Marchesoni, Diego

    2013-02-01

    Ovarian vein thrombosis (OVT) is an uncommon but potentially serious complication in the early postpartum. Two case studies seem to prove the point: Case 1 A 24-year-old woman was transferred to our hospital with the chief complaint of abdominal pain radiating to the right thigh, vomit, diarrhea, and a slight pyrexia (37.6 °C rectal). Five days earlier, she had a spontaneous vaginal delivery after labor induction. The woman appeared slightly distressed because of pain; vital signs were found to be normal and the CRP elevated (129.9 mg/L). Abdominal examination was remarkable for tenderness by palpation in the right lower quadrant with no rebound tenderness or guarding. Pelvic examination was remarkable for mild right adnexal tenderness. Abdominal-pelvic computer tomography with contrast medium revealed a 2.5-cm OVT having extended into the inferior vena cava for 14 cm with a slight peripheral edema. The patient was treated with nadroparin 0.6 cc (5700 IU) bid and warfarin 5 mg since the attainment of the therapeutic INR range. Case 2 A 31-year-old twin-pregnant woman had an emergency cesarean section at 35 gestational weeks because of hypertension complicated by increased liver enzymes, diuresis contraction, and continuous lower back pain bilaterally radiating to the groins. One day after delivery, CT scan that was performed because of onward anemia showed a pelvic, perihepatic, and perisplenic blood effusion, and a 1-cm right OVT extended to the inferior vena cava below renal veins for 28 mm. She underwent exploratory laparotomy and blood transfusion, and because of respiratory insufficiency she was transferred to a second level center with ICU facility, where she was placed under a suprarenal inferior vena cava filter, and AngioJet Rheolytic Thrombectomy for acute pulmonary embolism was performed.

  20. Facial Emotion Recognition Using Context Based Multimodal Approach

    Directory of Open Access Journals (Sweden)

    Priya Metri

    2011-12-01

    Full Text Available Emotions play a crucial role in person to person interaction. In recent years, there has been a growing interest in improving all aspects of interaction between humans and computers. The ability to understand human emotions is desirable for the computer in several applications especially by observing facial expressions. This paper explores a ways of human-computer interaction that enable the computer to be more aware of the user’s emotional expressions we present a approach for the emotion recognition from a facial expression, hand and body posture. Our model uses multimodal emotion recognition system in which we use two different models for facial expression recognition and for hand and body posture recognition and then combining the result of both classifiers using a third classifier which give the resulting emotion . Multimodal system gives more accurate result than a signal or bimodal system

  1. Contralateral Deep Vein Thrombosis after Iliac Vein Stent Placement in Patients with May-Thurner Syndrome.

    Science.gov (United States)

    Le, Trong Binh; Lee, Taeg Ki; Park, Keun-Myoung; Jeon, Yong Sun; Hong, Kee Chun; Cho, Soon Gu

    2018-04-25

    To investigate the incidence and potential causes of contralateral deep vein thrombosis (DVT) after common iliac vein (CIV) stent placement in patients with May-Thurner syndrome (MTS). Data of 111 patients (women: 73%) who had CIV stent implantation for symptomatic MTS at a single center were retrospectively analyzed. Mean patient age was 63.1 ± 15.2 years. Median follow-up was 36 months (range, 1-142 months). Stent location was determined by venogram and classified as extended to the inferior vena cava (IVC), covered the confluence, or confined to the iliac vein. Potential causes of contralateral DVT were presumed based on venographic findings. The relationship between stent location and contralateral DVT was analyzed. Ten patients (9%, men/women: 4/6) exhibited contralateral DVT at a median timing of 40 months (range, 6-98 months). Median age was 69 years (range, 42-85 years). Median follow-up was 73.5 months (range, 20-134 months). Potential causes were venous intimal hyperplasia (VIH) (n = 7), "jailing" (n = 2), and indeterminate (n = 1). All patients with VIH had previous CIV stents overextended to the IVC. Overextension of CIV stent was associated with contralateral DVT (P VIH should be considered a potential cause. Copyright © 2018 SIR. Published by Elsevier Inc. All rights reserved.

  2. Percutaneous closure of patent ductus arteriosus in interrupted inferior caval vein through femoral vein approach

    Directory of Open Access Journals (Sweden)

    Endale Tefera

    2014-01-01

    Full Text Available Percutaneous closure of the patent arterial duct in patients with interrupted inferior caval vein poses a technical challenge. A 12-year-old girl with a patent ductus arteriosus (PDA and interrupted inferior caval vein is described in this report. The diagnosis of interrupted inferior caval vein and azygos continuation was made in the catheterization laboratory. A catheter was advanced and snared in the descending aorta. An exchange wire was advanced through the catheter and snared in the descending aorta. Then, an Amplatzer TorqVue 2 delivery sheath was advanced over the wire from the venous side and again snared in the descending aorta. An Amplatzer duct occluder (ADO size 8/6 was advanced through the sheath while still holding the sheath with a snare. The device was opened. The sheath was then unsnared once the aortic disc was completely out. The sheath and the device were pulled back into the duct and the device was successfully implanted. The device was then released and it attained a stable position. An aortic angiogram was performed which showed complete occlusion.

  3. Percutaneous closure of patent ductus arteriosus in interrupted inferior caval vein through femoral vein approach

    International Nuclear Information System (INIS)

    Tefera, Endale; Bermudez-Cañete, Ramon

    2014-01-01

    Percutaneous closure of the patent arterial duct in patients with interrupted inferior caval vein poses a technical challenge. A 12-year-old girl with a patent ductus arteriosus (PDA) and interrupted inferior caval vein is described in this report. The diagnosis of interrupted inferior caval vein and azygos continuation was made in the catheterization laboratory. A catheter was advanced and snared in the descending aorta. An exchange wire was advanced through the catheter and snared in the descending aorta. Then, an Amplatzer TorqVue 2 delivery sheath was advanced over the wire from the venous side and again snared in the descending aorta. An Amplatzer duct occluder (ADO) size 8/6 was advanced through the sheath while still holding the sheath with a snare. The device was opened. The sheath was then unsnared once the aortic disc was completely out. The sheath and the device were pulled back into the duct and the device was successfully implanted. The device was then released and it attained a stable position. An aortic angiogram was performed which showed complete occlusion

  4. Endovenous mechanochemical ablation of great saphenous vein incompetence using the ClariVein device: a safety study

    NARCIS (Netherlands)

    Eekeren, R. van; Boersma, D.; Elias, S.; Holewijn, S.; Werson, D.A.; Vries, J.P. de; Reijnen, M.M.P.J.

    2011-01-01

    PURPOSE: To evaluate the feasibility and safety of endovenous mechanochemical ablation (MOCA) for the treatment of great saphenous vein (GSV) incompetence. METHODS: The newly developed ClariVein device uses a technique that combines mechanical endothelial damage using a rotating wire with the

  5. Treatment of hepatic encephalopathy by retrograde transcaval coil embolization of an ileal vein-to-right gonadal vein portosystemic shunt

    International Nuclear Information System (INIS)

    Nishie, Akihiro; Yoshimitsu, Kengo; Honda, Hiroshi; Kaneko, Kuniyuki; Kuroiwa, Toshiro; Fukuya, Tatsuro; Irie, Hiroyuki; Ninomiya, Toshiharu; Yoshimitsu, Takahiro; Hirakata, Hideki; Okuda, Seiya; Masuda, Kouji

    1997-01-01

    A 43-year-old non-cirrhotic woman suffered from encephalopathy caused by an extrahepatic portosystemic shunt between the ileal vein and inferior vena cava via the right gonadal vein. Percutaneous transcatheter embolization with stainless steel coils was performed by the retrograde systemic venous approach. Encephalopathy improved dramatically

  6. Performance Comparison Between FEDERICA Hand and LARM Hand

    OpenAIRE

    Carbone, Giuseppe; Rossi, Cesare; Savino, Sergio

    2015-01-01

    This paper describes two robotic hands that have been\\ud developed at University Federico II of Naples and at the\\ud University of Cassino. FEDERICA Hand and LARM Hand\\ud are described in terms of design and operational features.\\ud In particular, careful attention is paid to the differences\\ud between the above-mentioned hands in terms of transmission\\ud systems. FEDERICA Hand uses tendons and pulleys\\ud to drive phalanxes, while LARM Hand uses cross four-bar\\ud linkages. Results of experime...

  7. Recognition of Handwriting from Electromyography

    Science.gov (United States)

    Linderman, Michael; Lebedev, Mikhail A.; Erlichman, Joseph S.

    2009-01-01

    Handwriting – one of the most important developments in human culture – is also a methodological tool in several scientific disciplines, most importantly handwriting recognition methods, graphology and medical diagnostics. Previous studies have relied largely on the analyses of handwritten traces or kinematic analysis of handwriting; whereas electromyographic (EMG) signals associated with handwriting have received little attention. Here we show for the first time, a method in which EMG signals generated by hand and forearm muscles during handwriting activity are reliably translated into both algorithm-generated handwriting traces and font characters using decoding algorithms. Our results demonstrate the feasibility of recreating handwriting solely from EMG signals – the finding that can be utilized in computer peripherals and myoelectric prosthetic devices. Moreover, this approach may provide a rapid and sensitive method for diagnosing a variety of neurogenerative diseases before other symptoms become clear. PMID:19707562

  8. Balloon-occluded retrograde transvenous obliteration of gastric varix draining via the left inferior phrenic vein into the left hepatic vein

    International Nuclear Information System (INIS)

    Ibukuro, Kenji; Mori, Koichi; Tsukiyama, Toshitaka; Inoue, Yoshihiro; Iwamoto, Yukako; Tagawa, Kazumi

    1999-01-01

    We encountered a patient with gastric varix draining not via the usual left suprarenal vein but via the left inferior phrenic vein joining the left hepatic vein. Transfemoral balloon-occluded retrograde transvenous obliteration (BRTO) of the varix was performed under balloon occlusion of the left inferior phrenic vein via the left hepatic vein and retrograde injection of the sclerosing agent (5% of ethanolamine oleate) into the gastric varix. Disappearance of the gastric varix was confirmed on endoscopic examination 2 months later.

  9. Supracardiac total anomalous pulmonary venous connection with a descending vertical vein.

    Science.gov (United States)

    Shah, Sejal; Singh, Mukesh; John, Colin; Maheshwari, Sunita

    2009-10-01

    The commonly used Darling classification for total anomalous pulmonary venous connection (TAPVC) consists of supracardiac, cardiac, infracardiac, and mixed types (Craig et al., Lab Invest 6:44-64, 1967). In supracardiac TAPVC, the common pulmonary vein drains superiorly into the left innominate vein, the superior vena cava, or the azygos vein by way of an ascending vertical vein. We describe a case of supracardiac TAPVC draining into the azygos vein atypically by way of a descending vertical vein.

  10. Second-hand signals

    DEFF Research Database (Denmark)

    Bergenholtz, Carsten

    2014-01-01

    Studies of signaling theory have traditionally focused on the dyadic link between the sender and receiver of the signal. Within a science‐based perspective this framing has led scholars to investigate how patents and publications of firms function as signals. I explore another important type...... used by various agents in their search for and assessment of products and firms. I conclude by arguing how this second‐hand nature of signals goes beyond a simple dyadic focus on senders and receivers of signals, and thus elucidates the more complex interrelations of the various types of agents...

  11. Hand grip strength

    DEFF Research Database (Denmark)

    Frederiksen, Henrik; Gaist, David; Petersen, Hans Christian

    2002-01-01

    in life is a major problem in terms of prevalence, morbidity, functional limitations, and quality of life. It is therefore of interest to find a phenotype reflecting physical functioning which has a relatively high heritability and which can be measured in large samples. Hand grip strength is known......-55%). A powerful design to detect genes associated with a phenotype is obtained using the extreme discordant and concordant sib pairs, of whom 28 and 77 dizygotic twin pairs, respectively, were found in this study. Hence grip strength is a suitable phenotype for identifying genetic variants of importance to mid...

  12. The hand and wrist

    International Nuclear Information System (INIS)

    Wood, M.B.; Berquist, T.H.

    1985-01-01

    Trauma is the most common etiologic factor leading to disability in the hand and wrist. Judicious radiographic evaluation is required for accurate assessment in practically all but the most minor of such injuries. Frequently serial radiographic evaluation is essential for directing the course of treatment and for following the healing process. A meaningful radiographic evaluation requires a comprehensive knowledge of the normal radiographic anatomy, an overview of the spectrum of pathology, and an awareness of the usual mechanisms of injury, appropriate treatment options, and relevant array of complications

  13. Paradigms in object recognition

    International Nuclear Information System (INIS)

    Mutihac, R.; Mutihac, R.C.

    1999-09-01

    A broad range of approaches has been proposed and applied for the complex and rather difficult task of object recognition that involves the determination of object characteristics and object classification into one of many a priori object types. Our paper revises briefly the three main different paradigms in pattern recognition, namely Bayesian statistics, neural networks, and expert systems. (author)

  14. Infant Visual Recognition Memory

    Science.gov (United States)

    Rose, Susan A.; Feldman, Judith F.; Jankowski, Jeffery J.

    2004-01-01

    Visual recognition memory is a robust form of memory that is evident from early infancy, shows pronounced developmental change, and is influenced by many of the same factors that affect adult memory; it is surprisingly resistant to decay and interference. Infant visual recognition memory shows (a) modest reliability, (b) good discriminant…

  15. Recognition and Toleration

    DEFF Research Database (Denmark)

    Lægaard, Sune

    2010-01-01

    Recognition and toleration are ways of relating to the diversity characteristic of multicultural societies. The article concerns the possible meanings of toleration and recognition, and the conflict that is often claimed to exist between these two approaches to diversity. Different forms or inter...

  16. Back to basics: hand hygiene and surgical hand antisepsis.

    Science.gov (United States)

    Spruce, Lisa

    2013-11-01

    Health care-associated infections (HAIs) are a significant issue in the United States and throughout the world, but following proper hand hygiene practices is the most effective and least expensive way to prevent HAIs. Hand hygiene is inexpensive and protects patients and health care personnel alike. The four general types of hand hygiene that should be performed in the perioperative environment are washing hands that are visibly soiled, hand hygiene using alcohol-based products, surgical hand scrubs, and surgical hand scrubs using an alcohol-based surgical hand rub product. Barriers to proper hand hygiene may include not thinking about it, forgetting, skin irritation, a lack of role models, or a lack of a safety culture. One strategy for improving hand hygiene practices is monitoring hand hygiene as part of a quality improvement project, but the most important aspect for perioperative team members is to set an example for other team members by following proper hand hygiene practices and reminding each other to perform hand hygiene. Copyright © 2013 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  17. Challenging ocular image recognition

    Science.gov (United States)

    Pauca, V. Paúl; Forkin, Michael; Xu, Xiao; Plemmons, Robert; Ross, Arun A.

    2011-06-01

    Ocular recognition is a new area of biometric investigation targeted at overcoming the limitations of iris recognition performance in the presence of non-ideal data. There are several advantages for increasing the area beyond the iris, yet there are also key issues that must be addressed such as size of the ocular region, factors affecting performance, and appropriate corpora to study these factors in isolation. In this paper, we explore and identify some of these issues with the goal of better defining parameters for ocular recognition. An empirical study is performed where iris recognition methods are contrasted with texture and point operators on existing iris and face datasets. The experimental results show a dramatic recognition performance gain when additional features are considered in the presence of poor quality iris data, offering strong evidence for extending interest beyond the iris. The experiments also highlight the need for the direct collection of additional ocular imagery.

  18. Dynamic Features for Iris Recognition.

    Science.gov (United States)

    da Costa, R M; Gonzaga, A

    2012-08-01

    The human eye is sensitive to visible light. Increasing illumination on the eye causes the pupil of the eye to contract, while decreasing illumination causes the pupil to dilate. Visible light causes specular reflections inside the iris ring. On the other hand, the human retina is less sensitive to near infra-red (NIR) radiation in the wavelength range from 800 nm to 1400 nm, but iris detail can still be imaged with NIR illumination. In order to measure the dynamic movement of the human pupil and iris while keeping the light-induced reflexes from affecting the quality of the digitalized image, this paper describes a device based on the consensual reflex. This biological phenomenon contracts and dilates the two pupils synchronously when illuminating one of the eyes by visible light. In this paper, we propose to capture images of the pupil of one eye using NIR illumination while illuminating the other eye using a visible-light pulse. This new approach extracts iris features called "dynamic features (DFs)." This innovative methodology proposes the extraction of information about the way the human eye reacts to light, and to use such information for biometric recognition purposes. The results demonstrate that these features are discriminating features, and, even using the Euclidean distance measure, an average accuracy of recognition of 99.1% was obtained. The proposed methodology has the potential to be "fraud-proof," because these DFs can only be extracted from living irises.

  19. Duplex sonography of the near-surface leg veins; Duplexsonographie der oberflaechlichen Beinvenen

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza, E.

    2007-07-01

    The book contains the following contributions: The ultrasonograph, selection of the ultrasonic transducer, anatomy of the near-surface vein system, physiology of the near-surface vein system, varicose status classification, systematics of the duplex sonography of near-surface leg veins, provocational maneuver for the duplex sonographic varicose diagnostics, exploration of vena saphena parva, perforans veins, side branches, phlebitis, sonography for varicose therapy, postsurgical sonography, deep leg veins, examination of near-surface leg veins for the pathology of the deep vein system, differential diagnostic clarification of leg oedema from the phlebologic-lymphological view, diagnostic side features along the near-surface leg veins.

  20. Conventional tomographic hilar anatomy emphasizing the pulmonary veins

    International Nuclear Information System (INIS)

    Genereux, G.P.

    1983-01-01

    The pulmonary hili are a frequent site of interpretive uncertainty because of thir complex anatomy. The right hilar shadow relates primarily to the ascending and descending pulmonary arteries and the right superior pulmonary vein, whereas the left hilar density accrues from the left pulmonary artery, left descending pulmonary artery, and left superior pulmonary vein. The right and left superoir pulmonary veins are intimately associated with and inseparable from the arteries. Knowledge of the course of these veins facilitates their identification on conventional tomograms. The right and left inferior pulmonary veins lie behind the lower hili and contribute only a small increment to the normal hilar density; the horizontal course of these vessels readily distinguishes them from the vertically oriented lower lobe arteries. Prominence of both the right and left superior and inferior veins may cause hilar pseudotumors. Conventional tomograms are most helpful in understanding plain radiographs. A multiview approach in anteroposterior, 55 0 posterior oblique, and lateral projections is recommended for a complete assessment. Computed tomography in transaxial sections adds further understanding of spatial relations in the hili, including the contributions of the pulmonary veins

  1. Non-contact finger vein acquisition system using NIR laser

    Science.gov (United States)

    Kim, Jiman; Kong, Hyoun-Joong; Park, Sangyun; Noh, SeungWoo; Lee, Seung-Rae; Kim, Taejeong; Kim, Hee Chan

    2009-02-01

    Authentication using finger vein pattern has substantial advantage than other biometrics. Because human vein patterns are hidden inside the skin and tissue, it is hard to forge vein structure. But conventional system using NIR LED array has two drawbacks. First, direct contact with LED array raise sanitary problem. Second, because of discreteness of LEDs, non-uniform illumination exists. We propose non-contact finger vein acquisition system using NIR laser and Laser line generator lens. Laser line generator lens makes evenly distributed line laser from focused laser light. Line laser is aimed on the finger longitudinally. NIR camera was used for image acquisition. 200 index finger vein images from 20 candidates are collected. Same finger vein pattern extraction algorithm was used to evaluate two sets of images. Acquired images from proposed non-contact system do not show any non-uniform illumination in contrary with conventional system. Also results of matching are comparable to conventional system. We developed Non-contact finger vein acquisition system. It can prevent potential cross contamination of skin diseases. Also the system can produce uniformly illuminated images unlike conventional system. With the benefit of non-contact, proposed system shows almost equivalent performance compared with conventional system.

  2. Palm Vein Verification Using Multiple Features and Locality Preserving Projections

    Directory of Open Access Journals (Sweden)

    Ali Mohsin Al-juboori

    2014-01-01

    Full Text Available Biometrics is defined as identifying people by their physiological characteristic, such as iris pattern, fingerprint, and face, or by some aspects of their behavior, such as voice, signature, and gesture. Considerable attention has been drawn on these issues during the last several decades. And many biometric systems for commercial applications have been successfully developed. Recently, the vein pattern biometric becomes increasingly attractive for its uniqueness, stability, and noninvasiveness. A vein pattern is the physical distribution structure of the blood vessels underneath a person’s skin. The palm vein pattern is very ganglion and it shows a huge number of vessels. The attitude of the palm vein vessels stays in the same location for the whole life and its pattern is definitely unique. In our work, the matching filter method is proposed for the palm vein image enhancement. New palm vein features extraction methods, global feature extracted based on wavelet coefficients and locality preserving projections (WLPP, and local feature based on local binary pattern variance and locality preserving projections (LBPV_LPP have been proposed. Finally, the nearest neighbour matching method has been proposed that verified the test palm vein images. The experimental result shows that the EER to the proposed method is 0.1378%.

  3. Renal Vein Reconstruction for Harvesting Injury in Kidney Transplantation

    Directory of Open Access Journals (Sweden)

    Birkan Bozkurt

    2014-03-01

    Full Text Available Kidney transplantation is the best treatment choice in the end-stage renal disease. In the renal transplantation, renal vein damage or shortness which occurs during cadaveric or living donor nephrectomy causes technical difficulties for surgeons. The lack of the donors already especially cadaveric, the acquirement of the graft, gets very much importance. In this report, it is aimed to share the clinical experiment by which it seen, how anastomosis can become appropriate by using the renal vein which is damaged in the way that anastomosis cannot be done anyway by using cadaveric vena cava graft. The renal vein brought to length for anostomosis which is repaired by using cadaveric vena cava graft, is anastomosed successfully by becoming an end-to-side of the external iliac vein of the recipient. Vascular anastomoses are applied easily in technique. The time of the warm ischemia was under 2 hours and the kidney was functional in the post-operative period. Renal vein trombosis was not observed. The renal vein damage occured during cadaveric or living donor nephrectomy, can be repaired by some methods. In the kidneys in which vein requirement is done, the success rates are rather high although acute tubular necrosis and delayed function can be seen more.

  4. Applied anatomic study of testicular veins in adult cadavers and in human fetuses

    Directory of Open Access Journals (Sweden)

    Luciano A. Favorito

    2007-04-01

    Full Text Available OBJECTIVES: Analyze the anatomic variations of the testicular veins in human cadavers and fetuses. MATERIALS AND METHODS: One hundred male adult cadavers and 24 fetuses were studied. Four anatomic aspects were considered: 1 Number of testicular veins, 2 The local of vein termination, 3 Type and number of collaterals present and 4 Testicular vein termination angle. RESULTS: Cadavers - Right side - One testicular vein occurred in 85% and 2 veins in 5% of the cases. There were communicating veins with the colon in 21% of the cases. Left side - One testicular vein occurred in 82%, two veins in 15%, three veins in 2% and four veins in 1% of the cases. There were communicating veins with the colon in 31% of the cases. Fetuses - Right side -One testicular vein occurred in all cases. This vein drained to the vena cava in 83.3% of the cases, to the junction of the vena cava with the renal vein in 12.5% and to the renal vein in 4.2%. There were communicating veins with the colon in 25% of the cases. Left side - One testicular vein occurred in 66.6% of the cases, and 2 veins in occurred 33.3%. Communicating veins with the colon were found in 41.6% of the cases. CONCLUSION: The testicular vein presents numeric variations and also variations in its local of termination. In approximately 30% of the cases, there are collaterals that communicate the testicular vein with retroperitoneal veins. These anatomic findings can help understanding the origin of varicocele and its recurrence after surgical interventions.

  5. The study of multi-detector CT on the grouping and measuring of the hepatic veins

    International Nuclear Information System (INIS)

    Wang Xianliang; Dong Guang; Geng Hai; Wang Wengang; Li Linkun; Gao Wei; Wang Rongfang

    2007-01-01

    Objective: To study the three-dimensional topography of the hepatic vein (HV), the inferior vena cava(IVC) and the inferior right hepatic vein(IRHV) in the retrohepatic and pre-IVC tunnel in human beings, and to provide an anatomic reference for liver surgery. Methods: One hundred and ten volunteers underwent CT scanning at 60 to 75 s after injection of contrast medium, and their HV, IVC and IRHV were reconstructed into MPR and 3D-MIP images. The hepatic veins were grouped according to the way by which the hepatic vein enters IVC. The angle between the right hepatic vein and the middle hepatic vein or the trunk of hepatic vein was measured, and the width from right hepatic vein to middle hepatic vein or to the trunk of hepatic vein on IVC was recorded. The frequency of IRHV was observed, and the length of the tunnel was measured. Results: Among the 110 volunteers, there were 6 cases (5.45%) with three hepatic veins respectively entering IVC, 98 cases (89.10%) with right hepatic vein and a common trunk of the middle hepatic vein and the left hepatic vein entering IVC, and 6 cases (5.45%) with left hepatic vein and a common trunk of the right hepatic vein and the middle hepatic vein entering IVC. The mean value of the angles between the right hepatic vein and the middle hepatic vein or the mink of hepatic vein was (55 ± 18) degree. The width from the right hepatic vein to the middle hepatic vein or to the trunk of hepatic vein was (21 ± 7)mm. The IRHV was observed in 30 cases(27.27%). The mean value of the tunnel length was (53 ± 11) mm. Conclusion: The parameters of the retrohepatic and pre-IVC tunnel in human beings can be measured accurately by the imaging of MPR, which can provide an anatomic reference for the liver surgery. (authors)

  6. Hand Matters: Left-Hand Gestures Enhance Metaphor Explanation

    Science.gov (United States)

    Argyriou, Paraskevi; Mohr, Christine; Kita, Sotaro

    2017-01-01

    Research suggests that speech-accompanying gestures influence cognitive processes, but it is not clear whether the gestural benefit is specific to the gesturing hand. Two experiments tested the "(right/left) hand-specificity" hypothesis for self-oriented functions of gestures: gestures with a particular hand enhance cognitive processes…

  7. Patterns recognition of electric brain activity using artificial neural networks

    Science.gov (United States)

    Musatov, V. Yu.; Pchelintseva, S. V.; Runnova, A. E.; Hramov, A. E.

    2017-04-01

    An approach for the recognition of various cognitive processes in the brain activity in the perception of ambiguous images. On the basis of developed theoretical background and the experimental data, we propose a new classification of oscillating patterns in the human EEG by using an artificial neural network approach. After learning of the artificial neural network reliably identified cube recognition processes, for example, left-handed or right-oriented Necker cube with different intensity of their edges, construct an artificial neural network based on Perceptron architecture and demonstrate its effectiveness in the pattern recognition of the EEG in the experimental.

  8. Self-taught axillary vein access without venography for pacemaker implantation: prospective randomized comparison with the cephalic vein access.

    Science.gov (United States)

    Squara, Fabien; Tomi, Julien; Scarlatti, Didier; Theodore, Guillaume; Moceri, Pamela; Ferrari, Emile

    2017-12-01

    Axillary vein access for pacemaker implantation is uncommon in many centres because of the lack of training in this technique. We assessed whether the introduction of the axillary vein technique was safe and efficient as compared with cephalic vein access, in a centre where no operators had any previous experience in axillary vein puncture. Patients undergoing pacemaker implantation were randomized to axillary or cephalic vein access. All three operators had no experience nor training in axillary vein puncture, and self-learned the technique by reading a published review. Axillary vein puncture was fluoroscopy-guided without contrast venography. Cephalic access was performed by dissection of delto-pectoral groove. Venous access success, venous access duration (from skin incision to guidewire or lead in superior vena cava), procedure duration, X-ray exposure, and peri-procedural (1 month) complications were recorded. results We randomized 74 consecutive patients to axillary (n = 37) or cephalic vein access (n = 37). Axillary vein was successfully accessed in 30/37 (81.1%) patients vs. 28/37 (75.7%) of cephalic veins (P = 0.57). Venous access time was shorter in axillary group than in cephalic group [5.7 (4.4-8.3) vs. 12.2 (10.5-14.8) min, P < 0.001], as well as procedure duration [34.8 (30.6-38.4) vs. 42.0 (39.1-46.6) min, P = 0.043]. X-ray exposure and peri-procedural overall complications were comparable in both groups. Axillary puncture was safe and faster than cephalic access even for the five first procedures performed by each operator. Self-taught axillary vein puncture for pacemaker implantation seems immediately safe and faster than cephalic vein access, when performed by electrophysiologists trained to pacemaker implantation but not to axillary vein puncture. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For Permissions, please email: journals.permissions@oup.com.

  9. Deep vein thrombosis as a paraneoplastic syndrome

    Directory of Open Access Journals (Sweden)

    Klačar Marija

    2014-01-01

    Full Text Available Introduction: Several conditions represent the risk factor for deep vein thrombosis (DVT but sometimes it occurs with no apparent reason. DVT usually involve lower extremities. It can be a component of paraneoplastic syndrome, and occasionally it is the first manifestation of malignancy. Case report: Fifty-five years old male reported to his general practitioner with history of painless right leg swelling of three weeks duration. He denied leg trauma or any other hardship. The patient had a long history of hypertension and took his medications irregularly. Family history was positive for cardiovascular diseases but negative for metabolic diseases or malignancies. He was a smoker and physically active. Physical examination revealed right calf swelling without skin discoloration, distention of superficial veins or trophic changes. Pulses of magistral arteries of the leg were symmetrical, Homans' sign was positive on the right leg. The rest of the physical examination was normal, except for the blood pressure. He was referred to vascular surgeon with the clinical diagnosis of femoro- popliteal phlebothrombosis of the right leg. Vascular surgeon performed the Color duplex scan of the lower extremities which confirmed the diagnosis. The patient was treated with low-molecular-weight heparin. The swelling significantly subsided after two weeks of therapy, but then patient fell and fractured left ramus of ischial bone. X-ray examination of pelvis revealed both fracture line and osteoblastic deposits in pelvis and the fracture was pronounced pathological. In order to localize the primary tumor, subsequent tests included chest X-ray, abdominal and pelvic ultrasound and digitorectal examination of prostate were performed. The results of all of the above mentioned examinations were within normal ranges, including routine blood tests. Skeletal scintigraphy revealed multiple secondary deposits in pelvic bones, vertebral column and ribs. Tumor markers' values

  10. On the Feasibility of Interoperable Schemes in Hand Biometrics

    Directory of Open Access Journals (Sweden)

    Miguel A. Ferrer

    2012-02-01

    Full Text Available Personal recognition through hand-based biometrics has attracted the interest of many researchers in the last twenty years. A significant number of proposals based on different procedures and acquisition devices have been published in the literature. However, comparisons between devices and their interoperability have not been thoroughly studied. This paper tries to fill this gap by proposing procedures to improve the interoperability among different hand biometric schemes. The experiments were conducted on a database made up of 8,320 hand images acquired from six different hand biometric schemes, including a flat scanner, webcams at different wavelengths, high quality cameras, and contactless devices. Acquisitions on both sides of the hand were included. Our experiment includes four feature extraction methods which determine the best performance among the different scenarios for two of the most popular hand biometrics: hand shape and palm print. We propose smoothing techniques at the image and feature levels to reduce interdevice variability. Results suggest that comparative hand shape offers better performance in terms of interoperability than palm prints, but palm prints can be more effective when using similar sensors.

  11. On the feasibility of interoperable schemes in hand biometrics.

    Science.gov (United States)

    Morales, Aythami; González, Ester; Ferrer, Miguel A

    2012-01-01

    Personal recognition through hand-based biometrics has attracted the interest of many researchers in the last twenty years. A significant number of proposals based on different procedures and acquisition devices have been published in the literature. However, comparisons between devices and their interoperability have not been thoroughly studied. This paper tries to fill this gap by proposing procedures to improve the interoperability among different hand biometric schemes. The experiments were conducted on a database made up of 8,320 hand images acquired from six different hand biometric schemes, including a flat scanner, webcams at different wavelengths, high quality cameras, and contactless devices. Acquisitions on both sides of the hand were included. Our experiment includes four feature extraction methods which determine the best performance among the different scenarios for two of the most popular hand biometrics: hand shape and palm print. We propose smoothing techniques at the image and feature levels to reduce interdevice variability. Results suggest that comparative hand shape offers better performance in terms of interoperability than palm prints, but palm prints can be more effective when using similar sensors.

  12. On the Feasibility of Interoperable Schemes in Hand Biometrics

    Science.gov (United States)

    Morales, Aythami; González, Ester; Ferrer, Miguel A.

    2012-01-01

    Personal recognition through hand-based biometrics has attracted the interest of many researchers in the last twenty years. A significant number of proposals based on different procedures and acquisition devices have been published in the literature. However, comparisons between devices and their interoperability have not been thoroughly studied. This paper tries to fill this gap by proposing procedures to improve the interoperability among different hand biometric schemes. The experiments were conducted on a database made up of 8,320 hand images acquired from six different hand biometric schemes, including a flat scanner, webcams at different wavelengths, high quality cameras, and contactless devices. Acquisitions on both sides of the hand were included. Our experiment includes four feature extraction methods which determine the best performance among the different scenarios for two of the most popular hand biometrics: hand shape and palm print. We propose smoothing techniques at the image and feature levels to reduce interdevice variability. Results suggest that comparative hand shape offers better performance in terms of interoperability than palm prints, but palm prints can be more effective when using similar sensors. PMID:22438714

  13. CT imaging of collaterals in stenoses of large mediastinal veins

    International Nuclear Information System (INIS)

    Goerich, J.; Flentje, M.; Gueckel, F.; Beyer-Enke, S.A.; Kaick, G. van; Heidelberg Univ.

    1988-01-01

    Scans of angio-computed tomography (CT) of 53 patients suffering from mediastinal space-occupying growths were reviewed: 16 patients showed stenosis of mediastinal veins with demonstration of subcutaneous venous channels, 17 showed an obstruction without collateral pathways and 20 patients had normal mediastinal vessels. Two thirds of the cases with external vein compression were caused by bronchogenic carcinoma. The degree of obstruction in patients showing collateral circulation was between 70 and 100 percent and significantly greater than in patients without collaterals (40%). The most important collaterals bypassing the upper mediastinal veins are discussed. (orig.) [de

  14. Bilateral retinal vein occlusion and rubeosis irides: lessons to learn.

    Science.gov (United States)

    Md Noh, Umi Kalthum; Ahem, Amin; Mustapha, Mushawiahti

    2013-01-01

    Uncontrolled hypertension is well- known to give rise to systemic complications involving multiple central organs. Artherosclerosis leads to damage of the retinal vessels wall, contributing to venous stasis, thrombosis and finally, occlusion. Retinal vein occlusions compromise vision through development of ischaemic maculopathy, macular oedema, and rubeotic glaucoma. Laser photocoagulation remains the definitive treatment for ischaemic vein occlusion with secondary neovascularization. Timely treatment with anti- vascular endothelial growth factor prevents development of rubeotic glaucoma. We hereby report an unusual case of bilateral retinal vein occlusion complicated by rubeosis irides, which was successfully managed to improve vision and prevent rubeotic glaucoma.

  15. Classification of hand eczema

    DEFF Research Database (Denmark)

    Agner, T; Aalto-Korte, K; Andersen, K E

    2015-01-01

    BACKGROUND: Classification of hand eczema (HE) is mandatory in epidemiological and clinical studies, and also important in clinical work. OBJECTIVES: The aim was to test a recently proposed classification system of HE in clinical practice in a prospective multicentre study. METHODS: Patients were...... recruited from nine different tertiary referral centres. All patients underwent examination by specialists in dermatology and were checked using relevant allergy testing. Patients were classified into one of the six diagnostic subgroups of HE: allergic contact dermatitis, irritant contact dermatitis, atopic...... system investigated in the present study was useful, being able to give an appropriate main diagnosis for 89% of HE patients, and for another 7% when using two main diagnoses. The fact that more than half of the patients had one or more additional diagnoses illustrates that HE is a multifactorial disease....

  16. The Hand-Foot Skin Reaction and Quality of Life Questionnaire: An Assessment Tool for Oncology

    OpenAIRE

    Anderson, Roger T.; Keating, Karen N.; Doll, Helen A.; Camacho, Fabian

    2015-01-01

    This study describes the development and validation of a brief, patient self-reported questionnaire (the hand-foot skin reaction and quality of life questionnaire) supporting its suitability for use in clinical research to aid in early recognition of symptoms, to evaluate the effectiveness of agents for hand-foot skin reaction (HFSR) or hand-foot syndrome (HFS) treatment within clinical trials, and to evaluate the impact of these treatments on HFS/R-associated patients’ health-related quality...

  17. Wide Awake Hand Surgery.

    Science.gov (United States)

    Lied, Line; Borchgrevink, Grethe E; Finsen, Vilhjalmur

    2017-09-01

    "Wide awake hand surgery", where surgery is performed in local anaesthesia with adrenaline, without sedation or a tourniquet, has become widespread in some countries. It has a number of potential advantages and we wished to evaluate it among our patients. All 122 patients treated by this method during one year were evaluated by the surgeons and the patients on a numerical scale from 0 (best/least) to 10 (worst/most). Theatre time was compared to that recorded for a year when regional or general anaesthesia had been used. The patients' mean score for the general care they had received was 0.1 (SD 0.6), for pain during lidocaine injection 2.4 (SD 2.2), for pain during surgery 0.9 (SD 1.5), and for other discomfort during surgery 0.5 (SD 1.4). Eight reported that they would want general anaesthesia if they were to be operated again. The surgeons' mean evaluation of bleeding during surgery was 1.6 (SD 1.8), oedema during surgery 0.4 (SD 1.1), general disadvantages with the method 1.0 (SD 1.6) and general advantages 6.5 (SD 4.3). The estimation of advantages was 9.9 (DS 0.5) for tendon suture. 28 patients needed intra-operative additional anaesthesia. The proportion was lower among trained hand surgeons and fell significantly during the study period. Non-surgical theatre time was 46 (SD 15) minutes during the study period and 55 (SD 22) minutes during the regional/general period (p theatre.

  18. Rheumatoid arthritis and hand surgery

    DEFF Research Database (Denmark)

    Peretz, Anne Sofie Rosenborg; Madsen, Ole Rintek; Brogren, Elisabeth

    2017-01-01

    Rheumatoid arthritis results in characteristic deformities of the hand. Medical treatment has undergone a remarkable development. However, not all patients achieve remission or tolerate the treatment. Patients who suffer from deformities and persistent synovitis may be candidates for hand surgery...

  19. Nitroprusside modulates pulmonary vein arrhythmogenic activity

    Directory of Open Access Journals (Sweden)

    Chen Yao-Chang

    2010-03-01

    Full Text Available Abstract Background Pulmonary veins (PVs are the most important sources of ectopic beats with the initiation of paroxysmal atrial fibrillation, or the foci of ectopic atrial tachycardia and focal atrial fibrillation. Elimination of nitric oxide (NO enhances cardiac triggered activity, and NO can decrease PV arrhythmogensis through mechano-electrical feedback. However, it is not clear whether NO may have direct electrophysiological effects on PV cardiomyocytes. This study is aimed to study the effects of nitroprusside (NO donor, on the ionic currents and arrhythmogenic activity of single cardiomyocytes from the PVs. Methods Single PV cardiomyocytes were isolated from the canine PVs. The action potential and ionic currents were investigated in isolated single canine PV cardiomyocytes before and after sodium nitroprusside (80 μM, using the whole-cell patch clamp technique. Results Nitroprusside decreased PV cardiomyocytes spontaneous beating rates from 1.7 ± 0.3 Hz to 0.5 ± 0.4 Hz in 9 cells (P Conclusion Nitroprusside regulates the electrical activity of PV cardiomyocytes, which suggests that NO may play a role in PV arrhythmogenesis.

  20. 8 CFR 292.2 - Organizations qualified for recognition; requests for recognition; withdrawal of recognition...

    Science.gov (United States)

    2010-01-01

    ...; requests for recognition; withdrawal of recognition; accreditation of representatives; roster. 292.2...; withdrawal of recognition; accreditation of representatives; roster. (a) Qualifications of organizations. A non-profit religious, charitable, social service, or similar organization established in the United...

  1. Management of Atopic Hand Dermatitis

    DEFF Research Database (Denmark)

    Halling-Overgaard, Anne-Sofie; Zachariae, Claus; Thyssen, Jacob P

    2017-01-01

    This article provides an overview of clinical aspects of hand eczema in patients with atopic dermatitis. Hand eczema can be a part of atopic dermatitis itself or a comorbidity, for example, as irritant or allergic contact dermatitis. When managing hand eczema, it is important to first categorize...

  2. Hand Washing: Do's and Dont's

    Science.gov (United States)

    ... hands frequently can help limit the transfer of bacteria, viruses and other microbes. Always wash your hands before: Preparing food or eating Treating wounds or caring for a sick person Inserting or removing contact lenses Always wash your hands after: Preparing food Using ...

  3. Hand aperture patterns in prehension.

    Science.gov (United States)

    Bongers, Raoul M; Zaal, Frank T J M; Jeannerod, Marc

    2012-06-01

    Although variations in the standard prehensile pattern can be found in the literature, these alternative patterns have never been studied systematically. This was the goal of the current paper. Ten participants picked up objects with a pincer grip. Objects (3, 5, or 7cm in diameter) were placed at 30, 60, 90, or 120cm from the hands' starting location. Usually the hand was opened gradually to a maximum immediately followed by hand closing, called the standard hand opening pattern. In the alternative opening patterns the hand opening was bumpy, or the hand aperture stayed at a plateau before closing started. Two participants in particular delayed the start of grasping with respect to start of reaching, with the delay time increasing with object distance. For larger object distances and smaller object sizes, the bumpy and plateau hand opening patterns were used more often. We tentatively concluded that the alternative hand opening patterns extended the hand opening phase, to arrive at the appropriate hand aperture at the appropriate time to close the hand for grasping the object. Variations in hand opening patterns deserve attention because this might lead to new insights into the coordination of reaching and grasping. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Gd-DTPA-enhanced MR venography for varicose veins of the calf

    International Nuclear Information System (INIS)

    Kohata, Yoshiko; Naito, Akira; Ito, Katuhide.

    1995-01-01

    2D time-of-flight MR venography (2D TOF MRV) was performed in 16 patients (25 calves) with varicose veins and 2 volunteers (4 calves), and compared with venography. Sequential SPGR (TR/TE/FA=45 ms/7 ms/60deg) transverse images and/or GRASS (TR/TE/FA=100 ms/13 ms/60deg) transverse images were obtained for MRV. Superior presaturation pulse (S-SAT) was placed in 21 calves, and 0.05 mmol/kg Gd-DTPA was used in all calves. Projection MRVs were generated with maximum intensity projection (MIP) reconstruction. Regarding sequence parameter, S-SAT was useful to eliminate signal from artery that would obscure the signal of deep veins. The detectability of deep veins was improved with the use of S-SAT. In the comparison with venography, MRV could more clearly demonstrate varicose veins more than 5 mm in diameter and their drainage veins than venography. But it could not so clearly demonstrate deep veins as venography. It could not detect fine varicose veins less than 5 mm in diameter and connecting veins with valve insufficiency. In the examination of varicose veins, detection of deep veins, large varicose veins and their main drainage veins is clinically important, because diagnosis of patency of deep veins and dilatation of the drainage veins is necessary to choose the treatment, concluding conservative therapy, stripping and sclerotherapy. However, detection of fine varicose veins and connecting veins are not so important because those veins seldom need treatment. MRV was not so suitable for detection of deep veins, but very useful for detection of varicose veins more than 5 mm in diameter and their main drainage veins. In conclusion, MRV is non-invasive and effective method in varicose veins of calf, and it can take the place of venography with the improvement of deep vein detectability. (author)

  5. Recurrence of pulmonary vein conduction and atrial fibrillation after pulmonary vein isolation for atrial fibrillation

    DEFF Research Database (Denmark)

    Nilsson, Brian; Chen, Xu; Pehrson, Steen

    2006-01-01

    BACKGROUND: Both segmental ostial and circumferential extraostial pulmonary vein (PV) isolation have been proven effective in the treatment of atrial fibrillation (AF). However, the recurrence of AF and PV conduction after the 2 ablation strategies has never been compared in a randomized study...... isolation. Extraostial PV isolation was performed by encircling the paired left and right PVs, respectively, guided by an electroanatomic mapping system. RESULTS: A total of 84% of the patients had recurrent AF after the first PV isolation procedure, showing 72% with AF and 12% with organized left atrial...

  6. Percutaneous transhepatic portal vein stenting in a patient with benign non-transplant postoperative portal vein stenosis: A case report

    Directory of Open Access Journals (Sweden)

    KS Madhusudhan

    2013-01-01

    Full Text Available Extrahepatic portal vein stenosis is caused by a variety of benign and malignant diseases and results in development of symptoms due to portal hypertension. Benign post-surgical adhesions causing portal vein stenosis in non-transplant population is an uncommon etiology of portal hypertension. Endovascular treatment of such patients with angioplasty and stenting is uncommonly reported in literature. We report a case of portal hypertension caused by benign postoperative portal vein fibrosis, successfully treated by self-expandable metallic stent.

  7. Unimanual SNARC Effect: Hand Matters.

    Science.gov (United States)

    Riello, Marianna; Rusconi, Elena

    2011-01-01

    A structural representation of the hand embedding information about the identity and relative position of fingers is necessary to counting routines. It may also support associations between numbers and allocentric spatial codes that predictably interact with other known numerical spatial representations, such as the mental number line (MNL). In this study, 48 Western participants whose typical counting routine proceeded from thumb-to-little on both hands performed magnitude and parity binary judgments. Response keys were pressed either with the right index and middle fingers or with the left index and middle fingers in separate blocks. 24 participants responded with either hands in prone posture (i.e., palm down) and 24 participants responded with either hands in supine (i.e., palm up) posture. When hands were in prone posture, the counting direction of the left hand conflicted with the direction of the left-right MNL, whereas the counting direction of the right hand was consistent with it. When hands were in supine posture, the opposite was true. If systematic associations existed between relative number magnitude and an allocentric spatial representation of the finger series within each hand, as predicted on the basis of counting habits, interactions would be expected between hand posture and a unimanual version of the spatial-numerical association of response codes (SNARC) effect. Data revealed that with hands in prone posture a unimanual SNARC effect was present for the right hand, and with hands in supine posture a unimanual SNARC effect was present for the left hand. We propose that a posture-invariant body structural representation of the finger series provides a relevant frame of reference, a within-hand directional vector, that is associated to simple number processing. Such frame of reference can significantly interact with stimulus-response correspondence effects, like the SNARC, that have been typically attributed to the mapping of numbers on a left

  8. Unimanual SNARC Effect: Hand Matters

    Directory of Open Access Journals (Sweden)

    Marianna eRiello

    2011-12-01

    Full Text Available A structural representation of the hand embedding information about the identity and relative position of fingers is necessary to counting routines. It may also support associations between numbers and allocentric spatial codes that predictably interact with other known numerical spatial representations, such as the mental number line. In this study, 48 Western participants whose typical counting routine proceeded from thumb-to-little on both hands performed magnitude and parity binary judgments. Response keys were pressed either with the right index and middle fingers or with the left index and middle fingers in separate blocks. 24 participants responded with either hands in prone posture (i.e. palm down and 24 participants responded with either hands in supine (i.e. palm up posture. When hands were in prone posture, the counting direction of the left hand conflicted with the direction of the left-right mental number line, whereas the counting direction of the right hand was consistent with it. When hands were in supine posture, the opposite was true. If systematic associations existed between relative number magnitude and an allocentric spatial representation of the finger series within each hand, as predicted on the basis of counting habits, interactions would be expected between hand posture and a unimanual version of the Spatial-Numerical Association of Response Codes (SNARC effect. Data revealed that with hands in prone posture a unimanual SNARC effect was present for the right hand, and with hands in supine posture a unimanual SNARC effect was present for the left hand. We propose that a posture-invariant body structural representation of the finger series provides a relevant frame of reference, a within-hand directional vector, that is associated to simple number processing. Such frame of reference can significantly interact with stimulus-response correspondence effects that have been attributed to the mapping of numbers on a mental

  9. Harmonization versus Mutual Recognition

    DEFF Research Database (Denmark)

    Jørgensen, Jan Guldager; Schröder, Philipp

    The present paper examines trade liberalization driven by the coordination of product standards. For oligopolistic firms situated in separate markets that are initially sheltered by national standards, mutual recognition of standards implies entry and reduced profits at home paired with the oppor......The present paper examines trade liberalization driven by the coordination of product standards. For oligopolistic firms situated in separate markets that are initially sheltered by national standards, mutual recognition of standards implies entry and reduced profits at home paired...... countries and three firms, where firms first lobby for the policy coordination regime (harmonization versus mutual recognition), and subsequently, in case of harmonization, the global standard is auctioned among the firms. We discuss welfare effects and conclude with policy implications. In particular......, harmonized standards may fail to harvest the full pro-competitive effects from trade liberalization compared to mutual recognition; moreover, the issue is most pronounced in markets featuring price competition....

  10. CASE Recognition Awards.

    Science.gov (United States)

    Currents, 1985

    1985-01-01

    A total of 294 schools, colleges, and universities received prizes in this year's CASE Recognition program. Awards were given in: public relations programs, student recruitment, marketing, program pulications, news writing, fund raising, radio programming, school periodicals, etc. (MLW)

  11. Forensic speaker recognition

    NARCIS (Netherlands)

    Meuwly, Didier

    2013-01-01

    The aim of forensic speaker recognition is to establish links between individuals and criminal activities, through audio speech recordings. This field is multidisciplinary, combining predominantly phonetics, linguistics, speech signal processing, and forensic statistics. On these bases, expert-based

  12. Ovarian vein thrombosis – a rare but important complication of ...

    African Journals Online (AJOL)

    This case study highlights the clinical importance of ovarian vein thrombosis in the context of pelvic surgery for benign gynaecological conditions and the role of imaging, particularly computed tomography with reformatting, in confirming the diagnosis.

  13. Primary extraskeletal mesenchymal chondrosarcoma arising from the iliac vein

    Directory of Open Access Journals (Sweden)

    Hua Zhang

    2017-10-01

    Full Text Available The iliac vein is an extremely rare site for mesenchymal chondrosarcoma, and patients with primary extraskeletal mesenchymal chondrosarcoma arising from a vein always suffer a very poor prognosis. We report a case of a 45-year-old female who presented with a 5-month history of left leg edema in 2015. Contrast-enhanced computed tomography showed a large mass in the left iliac vein with scattered calcifications. Wide-margin resection was performed, and histopathologic and immunohistochemical analyses confirmed the presence of intraluminal mesenchymal chondrosarcoma with local invasion out of the vein wall. Due to poor patient compliance, postoperative neoadjuvant chemotherapy and radiotherapy were not started, and a bone scan performed 16 weeks postoperatively showed multiple bone metastases. The patient died on the twenty-fourth postoperative week.

  14. Geology of uranium vein-deposits in France

    International Nuclear Information System (INIS)

    Sarcia, J.A.; Carrat, J.; Poughon, A.; Sanselme, H.

    1958-01-01

    This paper gives an outline of the characteristics of the main uranium vein deposits in France; it underlines the structural, petrographic and metallogenic similarities of these deposits. (author) [fr

  15. Central Retinal Vein Occlusion AssociatedWith Sildenafil (Viagra

    Directory of Open Access Journals (Sweden)

    H C Obiudu

    2010-01-01

    Conclusion - Central retinal vein occlusion is a possible adverse effect of sildenafil use. Physicians should be vigilant while prescribing thismedication and avoid its use in patients with elevated intraocular pressure

  16. Stent Recanalization of Chronic Portal Vein Occlusion in a Child

    International Nuclear Information System (INIS)

    Cwikiel, Wojciech; Solvig, Jan; Schroder, Henrik

    2000-01-01

    An 8-year-old boy with a 21/2 year history of portal hypertension and repeated bleedings from esophageal varices, was referred for treatment. The 3.5-cm-long occlusion of the portal vein was passed and the channel created was stabilized with a balloon-expandable stent; a portosystemic stent-shunt was also created. The portosystemic shunt closed spontaneously within 1 month, while the recanalized segment of the portal vein remained open. The pressure gradient between the intrahepatic and extrahepatic portal vein branches dropped from 17 mmHg to 0 mmHg. The pressure in the portal vein dropped from 30 mmHg to 17 mmHg and the bleedings stopped. The next dilation of the stent was performed 12 months later due to an increased pressure gradient; the gastroesophageal varices disappeared completely. Further dilation of the stent was planned after 2, 4, and 6 years

  17. Geology and geochemistry of giant quartz veins from the ...

    Indian Academy of Sciences (India)

    Numerous younger thin quartz veins with somewhat similar orientation cut across the giant quartz .... Angular fragments of quartz are set in ... places along grain boundaries. ... Oxide values are in wt%, and trace element concentrations are.

  18. Management Strategy for Patients With Chronic Subclavian Vein Thrombosis.

    Science.gov (United States)

    Keir, Graham; Marshall, M Blair

    2017-02-01

    We performed a systematic review to determine best practice for the management of patients with chronic or subacute subclavian vein thrombosis. This condition is best managed with surgical excision of the first rib followed by long-term anticoagulation. Interventional techniques aimed at restoring patency are ineffective beyond 2 weeks postthrombosis. Additional therapeutic options should be made based on the severity of symptoms as well as vein status. Patients with milder symptoms are given decompression surgery followed by anticoagulation whereas patients with more severe symptoms are considered for either a jugular vein transposition or saphenous patch based on the vein characteristics. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  19. The Recognition Of Fatigue

    DEFF Research Database (Denmark)

    Elsass, Peter; Jensen, Bodil; Mørup, Rikke

    2007-01-01

    Elsass P., Jensen B., Morup R., Thogersen M.H. (2007). The Recognition Of Fatigue: A qualitative study of life-stories from rehabilitation clients. International Journal of Psychosocial Rehabilitation. 11 (2), 75-87......Elsass P., Jensen B., Morup R., Thogersen M.H. (2007). The Recognition Of Fatigue: A qualitative study of life-stories from rehabilitation clients. International Journal of Psychosocial Rehabilitation. 11 (2), 75-87...

  20. Evaluating music emotion recognition

    DEFF Research Database (Denmark)

    Sturm, Bob L.

    2013-01-01

    A fundamental problem with nearly all work in music genre recognition (MGR)is that evaluation lacks validity with respect to the principal goals of MGR. This problem also occurs in the evaluation of music emotion recognition (MER). Standard approaches to evaluation, though easy to implement, do...... not reliably differentiate between recognizing genre or emotion from music, or by virtue of confounding factors in signals (e.g., equalization). We demonstrate such problems for evaluating an MER system, and conclude with recommendations....

  1. Sciatica caused by a dilated epidural vein: MR findings

    Energy Technology Data Exchange (ETDEWEB)

    Demaerel, P.; Petre, C.; Wilms, G. [Dept. of Radiology, Catholic University of Leuven (Belgium); Plets, C. [Dept. of Neurosurgery, Catholic University of Leuven (Belgium)

    1999-02-01

    We report the MR imaging findings in a 41-year-old woman presenting with sudden low back pain and sciatica. At surgery a dilated epidural vein was found compressing the nerve root. The MR findings may suggest the diagnosis. Magnetic resonance imaging of a dilated epidural vein or varix causing sciatica has not been reported until now. (orig.) (orig.) With 1 fig., 4 refs.

  2. Sheathotomy in complicated cases of branch retinal vein occlusion

    DEFF Research Database (Denmark)

    Crafoord, S.; Karlsson, N.; Cour, M. la

    2008-01-01

    Purpose: To report the clinical experience and results of using a microsurgical technique to decompress the arteriovenous connection in complicated branch retinal vein occlusion (BRVO) combined with haemorrhage, oedema an ischaemia. Methods: We carried out a retrospective, non-randomized, interve......Purpose: To report the clinical experience and results of using a microsurgical technique to decompress the arteriovenous connection in complicated branch retinal vein occlusion (BRVO) combined with haemorrhage, oedema an ischaemia. Methods: We carried out a retrospective, non...

  3. Ultrasonography of the lower extremity veins: Anatomy and basic approach

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Kyu; Ahn, Kyung Sik; Kang, Chang Ho; Cho, Sung Bum [Dept. of Radiology, Korea University Anam Hospital, Korea University College of Medicine, Seoul (Korea, Republic of)

    2017-04-15

    Ultrasonography is an imaging modality widely used to evaluate venous diseases of the lower extremities. It is important to understand the normal venous anatomy of the lower extremities, which has deep, superficial, and perforating venous components, in order to determine the pathophysiology of venous disease. This review provides a basic description of the anatomy of the lower extremity veins and useful techniques for approaching each vein via ultrasonography.

  4. Branch retinal vein occlusion associated with quetiapine fumarate

    Directory of Open Access Journals (Sweden)

    Siang Lim

    2011-08-01

    Full Text Available Abstract Background To report a case of branch retinal vein occlusion in a young adult with bipolar mood disorder treated with quetiapine fumarate. Case Presentation A 29 years old gentleman who was taking quetiapine fumarate for 3 years for bipolar mood disorder, presented with sudden vision loss. He was found to have a superior temporal branch retinal vein occlusion associated with hypercholesterolemia. Conclusion Atypical antipsychotic drugs have metabolic side effects which require regular monitoring and prompt treatment.

  5. An unusual presentation of postpartum ovarian vein thrombosis

    International Nuclear Information System (INIS)

    Hakim, Fayaz A.; Khan, Nadra N.; Qushmaq, Khalid A.; Al-Shami, Sadiq Y.

    2007-01-01

    Ovarian vein thrombosis is a rare but potentially serious complication following childbirth. The majority of patients present during the first week postpartum, with fever and right lower quadrant abdominal pain. We report an unusual case of postpartum ovarian vein thrombosis who presented with fever, low backache, and painful thighs. A high index of suspicion is crucial to diagnose and treat this condition in order to avoid serious consequences. (author)

  6. [Ultrasound examination for lower extremity deep vein thrombosis].

    Science.gov (United States)

    Toyota, Kosaku

    2014-09-01

    Surgery is known to be a major risk factor of vein thrombosis. Progression from lower extremity deep vein thrombosis (DVT) to pulmonary embolism can lead to catastrophic outcome, although the incidence ratio is low. The ability to rule in or rule out DVT is becoming essential for anesthesiologists. Non-invasive technique of ultrasonography is a sensitive and specific tool for the assessment of lower extremity DVT. This article introduces the basics and practical methods of ultrasound examination for lower extremity DVT.

  7. Adult adrenal haemorrhage: an unrecognised complication of renal vein thrombosis

    Energy Technology Data Exchange (ETDEWEB)

    Loke, T.K.L. E-mail: lokekl@ha.org.hk

    2001-07-01

    There are many predisposing factors for neonatal adrenal haemorrhage but the causative factors are different in adults. Several cases of neonatal adrenal haemorrhage have been reported in association with renal vein thrombosis. This complication has not been documented in the adults. The presence of an adrenal mass in the setting of renal vein thrombosis should raise the possibility of adrenal haemorrhage even though this is extremely uncommon in adults.

  8. Congenital vascular malformations: the persistence of marginal and embryonal veins.

    Science.gov (United States)

    Weber, J; Daffinger, N

    2006-05-01

    In about 18% of cases with conginental vascular malformations we find a perspective of an atypical truncular vein, located along the outside of the leg, frequently extended from the dorsal foot up to the bottom. In presence of a normally developed system of the deep collecting veins of the lower limb and within the pelvic outflow we are talking about a persisting marginal vein (MV). Hypoplasia or even aplasia of the main deep veins in contrary defines the persisting embryonal vein (EV). Already in childhood these truncular dysplastic veins tend to develop varicose enlargement, causing severe reflux of a huge volume of blood--even more when being associated with av-fistulas (46%). In consequence a rapidly growing chronic venous insufficiency will guide to additional injuries. We have analysed 97 patients showing a persisting MV (n: 92 ) within a total of 102 legs. A persistent embryonal vein (EV) was seen 10 times within this clientel. The persisting truncular veins, associated with phlebectasias and typical clinical symptoms have been examined in a diagnostic "step-by-step" procedure, mainly phlebographically (ascending leg phlebography and varicography), including direct venous blood pressure measurements (phlebodynamometry) and--if needed--by arteriography, showing av-shunting fistulae in 46% of cases. CT and MRI were consulted for the exact therapy planing (frequently initially offered as a non-invasive, however, inadequate key of diagnostic). Actually now these techniques cannot replace pre-operatively the angiographic imaging techniques. The analysis of clinical, morphologic and functional signs, guiding to a specific therapy-relevant classification of MV's and EV's will be presented. And a specific strategy of surgical repair, interventional treatment of av-fistulas and conservative compressive follow-up treatment attempting palliative recompensation of the diseased venous outflow will be discussed also.

  9. Ultrasonography of the lower extremity veins: Anatomy and basic approach

    International Nuclear Information System (INIS)

    Lee, Dong Kyu; Ahn, Kyung Sik; Kang, Chang Ho; Cho, Sung Bum

    2017-01-01

    Ultrasonography is an imaging modality widely used to evaluate venous diseases of the lower extremities. It is important to understand the normal venous anatomy of the lower extremities, which has deep, superficial, and perforating venous components, in order to determine the pathophysiology of venous disease. This review provides a basic description of the anatomy of the lower extremity veins and useful techniques for approaching each vein via ultrasonography

  10. Arabic sign language recognition based on HOG descriptor

    Science.gov (United States)

    Ben Jmaa, Ahmed; Mahdi, Walid; Ben Jemaa, Yousra; Ben Hamadou, Abdelmajid

    2017-02-01

    We present in this paper a new approach for Arabic sign language (ArSL) alphabet recognition using hand gesture analysis. This analysis consists in extracting a histogram of oriented gradient (HOG) features from a hand image and then using them to generate an SVM Models. Which will be used to recognize the ArSL alphabet in real-time from hand gesture using a Microsoft Kinect camera. Our approach involves three steps: (i) Hand detection and localization using a Microsoft Kinect camera, (ii) hand segmentation and (iii) feature extraction using Arabic alphabet recognition. One each input image first obtained by using a depth sensor, we apply our method based on hand anatomy to segment hand and eliminate all the errors pixels. This approach is invariant to scale, to rotation and to translation of the hand. Some experimental results show the effectiveness of our new approach. Experiment revealed that the proposed ArSL system is able to recognize the ArSL with an accuracy of 90.12%.

  11. Why recognition is rational

    Directory of Open Access Journals (Sweden)

    Clintin P. Davis-Stober

    2010-07-01

    Full Text Available The Recognition Heuristic (Gigerenzer and Goldstein, 1996; Goldstein and Gigerenzer, 2002 makes the counter-intuitive prediction that a decision maker utilizing less information may do as well as, or outperform, an idealized decision maker utilizing more information. We lay a theoretical foundation for the use of single-variable heuristics such as the Recognition Heuristic as an optimal decision strategy within a linear modeling framework. We identify conditions under which over-weighting a single predictor is a mini-max strategy among a class of a priori chosen weights based on decision heuristics with respect to a measure of statistical lack of fit we call ``risk''. These strategies, in turn, outperform standard multiple regression as long as the amount of data available is limited. We also show that, under related conditions, weighting only one variable and ignoring all others produces the same risk as ignoring the single variable and weighting all others. This approach has the advantage of generalizing beyond the original environment of the Recognition Heuristic to situations with more than two choice options, binary or continuous representations of recognition, and to other single variable heuristics. We analyze the structure of data used in some prior recognition tasks and find that it matches the sufficient conditions for optimality in our results. Rather than being a poor or adequate substitute for a compensatory model, the Recognition Heuristic closely approximates an optimal strategy when a decision maker has finite data about the world.

  12. Robotically enhanced rubber hand illusion.

    Science.gov (United States)

    Arata, Jumpei; Hattori, Masashi; Ichikawa, Shohei; Sakaguchi, Masamichi

    2014-01-01

    The rubber hand illusion is a well-known multisensory illusion. In brief, watching a rubber hand being stroked by a paintbrush while one's own unseen hand is synchronously stroked causes the rubber hand to be attributed to one's own body and to "feel like it's my hand." The rubber hand illusion is thought to be triggered by the synchronized tactile stimulation of both the subject's hand and the fake hand. To extend the conventional rubber hand illusion, we introduce robotic technology in the form of a master-slave telemanipulator. The developed one degree-of-freedom master-slave system consists of an exoskeleton master equipped with an optical encoder that is worn on the subject's index finger and a motor-actuated index finger on the rubber hand, which allows the subject to perform unilateral telemanipulation. The moving rubber hand illusion has been studied by several researchers in the past with mechanically connected rigs between the subject's body and the fake limb. The robotic instruments let us investigate the moving rubber hand illusion with less constraints, thus behaving closer to the classic rubber hand illusion. In addition, the temporal delay between the body and the fake limb can be precisely manipulated. The experimental results revealed that the robotic instruments significantly enhance the rubber hand illusion. The time delay is significantly correlated with the effect of the multisensory illusion, and the effect significantly decreased at time delays over 100 ms. These findings can potentially contribute to the investigations of neural mechanisms in the field of neuroscience and of master-slave systems in the field of robotics.

  13. Beta irradiation inhibits neo-intimal formation in vein grafts

    International Nuclear Information System (INIS)

    Lang Xiaoou; Ji Shenquan; Zeng Ke; Li Jun; Liu Bingbing; Ma Wenfeng; Zhang Qiang

    2002-01-01

    Objective: The study was to evaluate the effect of beta irradiation on intimal proliferation response in vein grafts. Methods: An autogenous vein graft model was established in 40 rats by transplanting internal branch of jugular vein to carotid artery by end-to-end anastomosis. The vein was irradiated by 32 P before anastomosis. Four dose schedules were studied: (1) control graft (nonirradiated); (2) irradiated with 8 Gy; (3) 18 Gy; and (4) 36 Gy. The grafted veins were harvested at 2 weeks after the operation. IH (intimal hyperplasia) and SMC (smooth muscle cell) proliferation were histologically and immuno-histochemically observed and analyzed by a computer digitalising system. Results: In 18 Gy and 36 Gy-irradiated grafts compared with the control, there was a significant decrease in the average intimal thickness (P 0.05). Immunohistochemical analysis of PCNA indicated decrease of positive cells in both 18 Gy and 36 Gy groups compared with 8 Gy and the control group (P 0.05) groups, and there was also no significant difference between 8 Gy and the control group (P > 0.05). Conclusion: These preliminary results demonstrate that proper dose of beta irradiation in vein graft inhibits smooth muscle cells proliferation and neo-intimal hyperplasia in rat

  14. CO2-DSA in lower extremity veins: a clinical application

    International Nuclear Information System (INIS)

    Guo Jinhe; Teng Gaojun; Zhu Guangyu; Liu Zhensheng; Li Guozhao; Ding Huijuan; Shen Zhiping; He Shicheng; Deng Gang; Fang Wen

    2005-01-01

    Objective: To explore the feasibility and usefulness of carbon dioxide digital subtraction angiography (CO 2 -DSA) in deep veins of lower extremity via the dorsal is pedis vein. Methods: CO 2 -DSA in lower extremity veins was performed in 15 patients (15 limbs affected, male 9, female 6) by injection of CO 2 via the dorsal is pedis vein. Among them, 8 patients were suspected with deep venous thrombosis (DVT), 6 patients with saphena magna dilation, and 1 patient with a follow-up after thrombolysis due to DVT. Results: Excellent image was obtained in 12 cases, which showed branches of the venous system clearly, as well as the details of DVT. Good image was obtained in 2 cases. Technical failure was encountered in one patient due to inaccessible puncture veins. Mild discomfort (transient pain at the percutaneous site) during the procedure was demonstrated in 11 patients. There was no severe side effects or complications in this series. Conclusion: CO 2 -DSA in lower extremity veins is feasible and safe, the preliminary result is satisfactory. (authors)

  15. Varicography in the preoperative evaluation of primary varicose veins

    International Nuclear Information System (INIS)

    Pinzani, A.; Paoli, G.; Gongolo, A.; Spreafico, G.

    1989-01-01

    Primary varicose veins in the lower limb are usually well evaluated by the surgeon, who avails himself of tornequet tests and Doppler US. However, the operation is often followed by failure or recurrence, or else it requires ugly skin dissection to eradicate an unforeseeably complicated varicose vein. The authors suggest that, whenever the surgeon considers the information obtained with tests and Doppler US inadequate for planning surgery, varicography be performed to get further morphological (and functional) data about the origin of varicose veins, which is of fundamental importance for an accurate surgical planning (crossectomy, stripping, ligation, sclerosis). Out of 100 varicographies consecutively carried out on patients in whom clinical examination was not conclusive, 62% allowed an already planned surgical approach to be changed. The figure rose to 100% in the case of unusual varicose veins. Such a results allowed the needs of both the surgeon (selectivity, effectiveness, radicality) and the patients (narrow scars, absence of relapse) to be respected. Furthermore, it has been pointed out that some vein segments are often only pathological, and they are to be adequately treated, while others can be undamaged, and they are to be preserved for both their function and an eventual by-pass surgery. Varicography is rapidly performed, without complication, and is well accepted by the patients. It is a fundamental help in the preoperative study of primary varicose veins, especially in case of unusual ones, whenever the surgeon is in the slightest diagnostic - and therefore surgical - doubt

  16. Robust finger vein ROI localization based on flexible segmentation.

    Science.gov (United States)

    Lu, Yu; Xie, Shan Juan; Yoon, Sook; Yang, Jucheng; Park, Dong Sun

    2013-10-24

    Finger veins have been proved to be an effective biometric for personal identification in the recent years. However, finger vein images are easily affected by influences such as image translation, orientation, scale, scattering, finger structure, complicated background, uneven illumination, and collection posture. All these factors may contribute to inaccurate region of interest (ROI) definition, and so degrade the performance of finger vein identification system. To improve this problem, in this paper, we propose a finger vein ROI localization method that has high effectiveness and robustness against the above factors. The proposed method consists of a set of steps to localize ROIs accurately, namely segmentation, orientation correction, and ROI detection. Accurate finger region segmentation and correct calculated orientation can support each other to produce higher accuracy in localizing ROIs. Extensive experiments have been performed on the finger vein image database, MMCBNU_6000, to verify the robustness of the proposed method. The proposed method shows the segmentation accuracy of 100%. Furthermore, the average processing time of the proposed method is 22 ms for an acquired image, which satisfies the criterion of a real-time finger vein identification system.

  17. Robust Finger Vein ROI Localization Based on Flexible Segmentation

    Directory of Open Access Journals (Sweden)

    Dong Sun Park

    2013-10-01

    Full Text Available Finger veins have been proved to be an effective biometric for personal identification in the recent years. However, finger vein images are easily affected by influences such as image translation, orientation, scale, scattering, finger structure, complicated background, uneven illumination, and collection posture. All these factors may contribute to inaccurate region of interest (ROI definition, and so degrade the performance of finger vein identification system. To improve this problem, in this paper, we propose a finger vein ROI localization method that has high effectiveness and robustness against the above factors. The proposed method consists of a set of steps to localize ROIs accurately, namely segmentation, orientation correction, and ROI detection. Accurate finger region segmentation and correct calculated orientation can support each other to produce higher accuracy in localizing ROIs. Extensive experiments have been performed on the finger vein image database, MMCBNU_6000, to verify the robustness of the proposed method. The proposed method shows the segmentation accuracy of 100%. Furthermore, the average processing time of the proposed method is 22 ms for an acquired image, which satisfies the criterion of a real-time finger vein identification system.

  18. Robust Finger Vein ROI Localization Based on Flexible Segmentation

    Science.gov (United States)

    Lu, Yu; Xie, Shan Juan; Yoon, Sook; Yang, Jucheng; Park, Dong Sun

    2013-01-01

    Finger veins have been proved to be an effective biometric for personal identification in the recent years. However, finger vein images are easily affected by influences such as image translation, orientation, scale, scattering, finger structure, complicated background, uneven illumination, and collection posture. All these factors may contribute to inaccurate region of interest (ROI) definition, and so degrade the performance of finger vein identification system. To improve this problem, in this paper, we propose a finger vein ROI localization method that has high effectiveness and robustness against the above factors. The proposed method consists of a set of steps to localize ROIs accurately, namely segmentation, orientation correction, and ROI detection. Accurate finger region segmentation and correct calculated orientation can support each other to produce higher accuracy in localizing ROIs. Extensive experiments have been performed on the finger vein image database, MMCBNU_6000, to verify the robustness of the proposed method. The proposed method shows the segmentation accuracy of 100%. Furthermore, the average processing time of the proposed method is 22 ms for an acquired image, which satisfies the criterion of a real-time finger vein identification system. PMID:24284769

  19. [Treatment of nontumoral portal vein thrombosis in cirrhosis].

    Science.gov (United States)

    Bañares, Rafael; Catalina, María-Vega

    2014-07-01

    Portal vein thrombosis in cirrhosis is a relatively common complication associated with the presence of an accompanying prothrombotic phenotype of advanced cirrhosis. The consequences of portal vein thrombosis are relevant because it can be associated with impaired hepatic function, might contraindicate hepatic transplantation and could increase morbidity in the surgical procedure. There is controversy concerning the most effective treatment of portal vein thrombosis, which is based on information that is seldom robust and whose primary objective is to achieve a return to vessel patency. Various studies have suggested that starting anticoagulation therapy early is associated with portal vein repatency more frequently than without treatment and has a low rate of complications. There are no proven data on the type of anticoagulant (low-molecular-weight heparins or dicoumarin agents) and the treatment duration. The implementation of TIPS is technically feasible in thrombosis without cavernous transformation and is associated with portal vein recanalization in a significant proportion of cases. Thrombolytic therapy does not appear to present an adequate balance between efficacy and safety; its use is therefore not supported for this indication. The proper definition of treatment for portal vein thrombosis requires properly designed studies to delimit the efficacy and safety of the various alternatives. Copyright © 2014 Elsevier España, S.L. All rights reserved.

  20. Understanding organic nitrates – a vein hope?

    Science.gov (United States)

    Miller, Mark R; Wadsworth, Roger M

    2009-01-01

    The organic nitrate drugs, such as glyceryl trinitrate (GTN; nitroglycerin), are clinically effective in angina because of their dilator profile in veins and arteries. The exact mechanism of intracellular delivery of nitric oxide (NO), or another NO-containing species, from these compounds is not understood. However, mitochondrial aldehyde dehydrogenase (mtALDH) has recently been identified as an organic nitrate bioactivation enzyme. Nitrate tolerance, the loss of effect of organic nitrates over time, is caused by reduced bioactivation and/or generation of NO-scavenging oxygen-free radicals. In a recent issue of the British Journal of Pharmacology, Wenzl et al. show that guinea-pigs, deficient in ascorbate, also have impaired responsiveness to GTN, but nitrate tolerance was not due to ascorbate deficiency that exhibited divergent changes in mtALDH activity. Thus, the complex function of mtALDH appears to be the key to activation of GTN, the active NO species formed and the induction of tolerance that can limit clinical effectiveness of organic nitrate drugs. British Journal of Pharmacology (2009) 157, 565–567; doi:10.1111/j.1476-5381.2009.00193.x This article is part of a themed section on Endothelium in Pharmacology. For a list of all articles in this section see the end of this paper, or visit: http://www3.interscience.wiley.com/journal/121548564/issueyear?year=2009 The paper by Wenzl et al. is available from http://www3.interscience.wiley.com/cgi-bin/fulltext/122221718/PDFSTART PMID:19630835