WorldWideScience

Sample records for hand flexor tendon

  1. Efficacy of Low Level Laser Therapy After Hand Flexor Tendon Repair

    Science.gov (United States)

    Ayad, K. E.; El Gohary, H. M.; Abd Elrahman, M.; Abd El Mejeed, S. F.; Bekheet, A. B.

    2009-09-01

    Flexor tendon injury is a common problem requiring suturing repair followed by early postoperative mobilization. Muscle atrophy, joint stiffness, osteoarthritis, infection, skin necrosis, ulceration of joint cartilage and tendocutaneous adhesion are familiar complications produced by prolonged immobilization of surgically repaired tendon ruptures. The purpose of this study was to clarify the importance of low level laser therapy after hand flexor tendon repair in zone II. Thirty patients aging between 20 and 40 years were divided into two groups. Patients in group A (n = 15) received a conventional therapeutic exercise program while patients in group B (n = 15) received low level laser therapy combined with the same therapeutic exercise program. The results showed a statistically significant increase in total active motion of the proximal and distal interphalangeal joints as well as maximum hand grip strength at three weeks and three months postoperative, but improvement was more significant in group B. It was concluded that the combination of low level laser therapy and early therapeutic exercises was more effective than therapeutic exercises alone in improving total active motion of proximal and distal interphalangeal joints and hand grip strength after hand flexor tendon repair.

  2. Flexor Tendon Injuries

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is ... Hand Therapist? Media Find a Hand Surgeon Home Anatomy ... fields From * To * DESCRIPTION The muscles that bend (flex) the fingers are called flexor ...

  3. IFSSH Flexor Tendon Committee report 2014: from the IFSSH Flexor Tendon Committee (Chairman: Jin Bo Tang).

    Science.gov (United States)

    Tang, Jin Bo; Chang, James; Elliot, David; Lalonde, Donald H; Sandow, Michael; Vögelin, Esther

    2014-01-01

    Hand surgeons continue to search for the best surgical flexor tendon repair and treatment of the tendon sheaths and pulleys, and they are attempting to establish postoperative regimens that fit diverse clinical needs. It is the purpose of this report to present the current views, methods, and suggestions of six senior hand surgeons from six different countries - all experienced in tendon repair and reconstruction. Although certainly there is common ground, the report presents provocative views and approaches. The report reflects an update in the views of the committee. We hope that it is helpful to surgeons and therapists in treating flexor tendon injuries.

  4. [Flexor tendon repair: a short story].

    Science.gov (United States)

    Moutet, F; Corcella, D; Forli, A; Mesquida, V

    2014-12-01

    This short story of flexor tendon repair aims to illustrate hesitations and wanderings of this surgery. Obviously tendon repair was very early considered, but it developed and diffused rather lately. It became a routine practice only in 20th century. This was due on the one hand, in Occident, to the Galen's dogmatic interdiction, on the other hand, to the repair difficulties of this paradoxical structure. Actually tendon is made of fibroblasts and collagen (sticky substances), and then its only goal is to move. According to this necessity, whatever the used techniques are, gliding is the final purpose. Technical evolutions are illustrated by historical contributions to flexor tendon surgery of several "giants" of hand surgery. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  5. Bilateral spontaneous rupture of flexor digitorum profundus tendons.

    LENUS (Irish Health Repository)

    O'Sullivan, S T

    2012-02-03

    Spontaneous tendon rupture is an unusual condition usually associated with underlying disease processes such as rheumatoid arthritis, chronic renal failure or bony abnormalities of the hand. We report a case of spontaneous, non-concurrent bilateral rupture of flexor profundus tendons in an otherwise healthy individual. Treatment was successful and consisted of a two-stage reconstruction of the ruptured tendon.

  6. Flexor tendon lacerations in zone V.

    Science.gov (United States)

    Stefanich, R J; Putnam, M D; Peimer, C A; Sherwin, F S

    1992-03-01

    Twenty-three patients with zone V flexor tendon lacerations rehabilitated by the Kleinert protocol were studied at an average of 46 months after trauma. Hand function was subjectively normal in only eight. Of fourteen patients who were employed at the time of injury, eight returned to their original occupations. Eight others were working at other jobs, and we considered six more capable of employment. Only one had a poor functional result that precluded occupational use of the hand. Pinch/grip strengths recovered to 85%/79% of the uninvolved side. Independent flexor digitorum superficialis/flexor digitorum profundus action was present in only seven patients. Sixteen regained full digital flexion. Extension loss averaged 25% at the wrist and 10% in each digit. As assessed by static two-point discrimination, sensibility was poor after associated median and ulnar nerve transections; this did not preclude good objective functional results. Complications included two tendon ruptures, proximal interphalangeal hyperextension in the presence of an unrepaired flexor digitorum superficialis, and limited motion in two patients after poor compliance in therapy. Tenolysis was needed in 4 of the 23. We now use a modified Duran technique for noncompliant patients and in those who are unable to extend their PIP joints because of weak intrinsic muscles.

  7. Acute flexor tendon injury following midshaft radius and ulna fractures in a paediatric patient

    Directory of Open Access Journals (Sweden)

    James Williams

    2018-06-01

    Full Text Available Delayed rupture of the extensor and flexor tendons are recognised complications of distal radius fractures. However, acute flexor tendon rupture in the context of forearm fractures is rare. A twelve-year-old female sustained midshaft fractures of the radius and ulna. Intra-operatively the flexor pollicis longus (FPL was found to be stripped from its musculotendinous junction at the level of the fracture fragment. The ruptured tendon was repaired using a modified Krackow technique at the time of fracture fixation. The repair was protected in plaster of Paris prior to referral to the paediatric hand clinic. The patient made a full recovery. Flexor tendon injury is a rare but potentially devastating consequence of acute forearm fractures. High energy trauma, significant volar angulation of the fracture fragment and clinical signs of flexor tendon injury should raise suspicion of this injury. A high index of suspicion in conjunction with repeat clinical examination of flexor tendon function should be performed before opting for closed management or intramedullary nailing in paediatric patients. Keywords: Acute, Flexor, Tendon, Fracture, Radius, Paediatric

  8. Step Cut Lengthening: A Technique for Treatment of Flexor Pollicis Longus Tendon Rupture.

    Science.gov (United States)

    Chong, Chew-Wei; Chen, Shih-Heng

    2018-04-01

    Reconstruction of a tendon defect is a challenging task in hand surgery. Delayed repair of a ruptured flexor pollicis longus (FPL) tendon is often associated with tendon defect. Primary repair of the tendon is often not possible, particularly after debridement of the unhealthy segment of the tendon. As such, various surgical treatments have been described in the literature, including single-stage tendon grafting, 2-stage tendon grafting, flexor digitorum superficialis tendon transfer from ring finger, and interphalangeal joint arthrodesis. We describe step cut lengthening of FPL tendon for the reconstruction of FPL rupture. This is a single-stage reconstruction without the need for tendon grafting or tendon transfer. To our knowledge, no such technique has been previously described.

  9. Nickel-titanium wire in circumferential suture of a flexor tendon repair: a comparison to polypropylene.

    Science.gov (United States)

    Karjalainen, T; He, M; Chong, A K S; Lim, A Y T; Ryhanen, J

    2010-07-01

    Nickel-titanium (NiTi) has been proposed as an alternative material for flexor tendon core suture. To our knowledge, its suitability as a circumferential suture of flexor tendon repair has not been investigated before. The purpose of this ex vivo study was to investigate the biomechanical properties of NiTi circumferential repairs and to compare them with commonly used polypropylene. Forty porcine flexor tendons were cut and repaired by simple running or interlocking mattress technique using 100 microm NiTi wire or 6-0 polypropylene. The NiTi circumferential repairs showed superior stiffness, gap resistance, and load to failure when compared to polypropylene repairs with both techniques. Nickel-titanium wire seems to be a potential material for circumferential repair of flexor tendons. Copyright 2010 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  10. MRI in flexor tendon rupture after collagenase injection

    International Nuclear Information System (INIS)

    Khurana, Shruti; Wadhwa, Vibhor; Chhabra, Avneesh; Amirlak, Bardia

    2017-01-01

    Flexor tendon rupture is an unusual complication following collagenase injection to relieve contractures. These patients require a close follow-up and in the event of tendon rupture, a decision has to be made whether to repair the tendon or manage the complication conservatively. The authors report the utility of MRI in the prognostication and management of a patient with Dupuytren's contracture, who underwent collagenase injection and subsequently developed flexor digitorum profundus tendon rupture. (orig.)

  11. MRI in flexor tendon rupture after collagenase injection

    Energy Technology Data Exchange (ETDEWEB)

    Khurana, Shruti [Lady Hardinge Medical College, New Delhi (India); Wadhwa, Vibhor [University of Arkansas for Medical Sciences, Little Rock, AR (United States); Chhabra, Avneesh [UT Southwestern Medical Center, Dallas, TX (United States); Johns Hopkins University, Baltimore, MD (United States); Amirlak, Bardia [UT Southwestern Medical Center, Dallas, TX (United States)

    2017-02-15

    Flexor tendon rupture is an unusual complication following collagenase injection to relieve contractures. These patients require a close follow-up and in the event of tendon rupture, a decision has to be made whether to repair the tendon or manage the complication conservatively. The authors report the utility of MRI in the prognostication and management of a patient with Dupuytren's contracture, who underwent collagenase injection and subsequently developed flexor digitorum profundus tendon rupture. (orig.)

  12. [The history of flexor tendon surgery].

    Science.gov (United States)

    Chamay, A

    1997-01-01

    Flexor tendon injuries were already treated in antiquity by Hippocrates, Galien and Avicenne. Since the Renaissance, other surgeons have attempted to repair flexor tendon injuries, but without success due to problems related to unsuitable materials and ignorance of the basic rules of asepsis and the absence of antiseptics until the second half of the 19th century. The first successful flexor tendon grafts in man were performed by K. Biesalski in 1910, E. Lexer in 1912 and L. Mayer in 1916. These three authors published their series of grafts and described in detail the anatomical, physiological and technical principles to be respected. St. Bunnell, in 1918, developed various pull-out direct suture procedures, but faced with the problems of adhesions, he abandoned this technique and proposed not to repair flexors in the digital tunnels but to graft them. He defined the famous zone which he called No man's land, which subsequently became Claude Verdan's zone II, in 1959. In 1960, C. Verdan published his first series of sutures maintained by 2 pins in zone II with comparable results to those obtained after grafting. In 1967, H. Kleinert, with his mobile suture, became the leader of direct tendon repair in zone II. 2-stage grafts were introduced in 1965 under the impetus of J. Hunter, who revised and popularized the studies conducted by A. Bassett and R.E. Caroll in 1950.

  13. Effects of Non-Steroidal Anti-Inflammatory Drugs onFlexor Tendon Rehabilitation after Repair

    Directory of Open Access Journals (Sweden)

    Alireza Rouhani

    2013-09-01

    Full Text Available   Background: Peritendinous adhesions after repairing an injury to the digital flexor tendons are a major problem in hand surgery. Non-steroidal anti-inflammatory drug therapy may affect tendon healing and the development of peritendinous adhesions. The aim of this study was to evaluate ibuprofen effect in patients function after flexor tendon surgical repair.   Method: Thirty-five patients, who had sharp-edge lacerations of hand-zone II requiring flexor tendons repair, participated in this randomized double-blind clinical trial study. The patients were randomly classified into two parallel and matched groups (21 patients in the intervention group and 14 patients in the control group. The groups were matched considering age, gender, and laceration size. The control group received a placebo with the same appearance and dosage. In the intervention group, ibuprofen was prescribed at a high dosage (2400 mg/day. The range of motion improvement rate of the involved fingers and the patients’ performance after their follow-up period were compared. Results: There was a statistically significant difference between the two groups for range of motion of the involved finger joints (P=0.03. According to the DASH score, there was a statistically significant difference between the final performance of the patients, such that it was 11±2.4 and 18.4±6.3 in the intervention and control groups, respectively (P=0.01. There was not any case of re-tear or need to re-operate in the intervention and control groups. Conclusion: Our findings reveal that ibuprofen with an anti-inflammatory dose was effective in improving the range of motion of the involved fingers joints after flexor tendon injury.

  14. Effects of Non-Steroidal Anti-Inflammatory Drugs onFlexor Tendon Rehabilitation after Repair

    Directory of Open Access Journals (Sweden)

    Alireza Rouhani

    2013-09-01

    Full Text Available Background: Peritendinous adhesions after repairing an injury to the digital flexor tendons are a major problem in hand surgery. Non-steroidal anti-inflammatory drug therapy may affect tendon healing and the development of peritendinous adhesions. The aim of this study was to evaluate ibuprofen effect in patients function after flexor tendon surgical repair.   Method: Thirty-five patients, who had sharp-edge lacerations of hand-zone II requiring flexor tendons repair, participated in this randomized double-blind clinical trial study. The patients were randomly classified into two parallel and matched groups (21 patients in the intervention group and 14 patients in the control group. The groups were matched considering age, gender, and laceration size. The control group received a placebo with the same appearance and dosage. In the intervention group, ibuprofen was prescribed at a high dosage (2400 mg/day. The range of motion improvement rate of the involved fingers and the patients’ performance after their follow-up period were compared. Results: There was a statistically significant difference between the two groups for range of motion of the involved finger joints (P=0.03. According to the DASH score, there was a statistically significant difference between the final performance of the patients, such that it was 11±2.4 and 18.4±6.3 in the intervention and control groups, respectively (P=0.01. There was not any case of re-tear or need to re-operate in the intervention and control groups. Conclusion: Our findings reveal that ibuprofen with an anti-inflammatory dose was effective in improving the range of motion of the involved fingers joints after flexor tendon injury.

  15. Cerebral consequences of dynamic immobilisation after primary digital flexor tendon repair

    NARCIS (Netherlands)

    Stenekes, M W; Coert, J H; Nicolai, J-P A; Mulder, Th; Geertzen, J H B; Paans, A M; de Jong, BM

    2010-01-01

    Current treatment protocols for flexor tendon injuries of the hand generally result in an acceptable function, which can be quantified by objective parameters such as range of motion. The latter does not always match the patients' subjective experiences of persisting dysfunction. This raises the

  16. Evaluation of the equine digital flexor tendon sheath using diagnostic ultrasound and contrast radiography

    International Nuclear Information System (INIS)

    Redding, W.R.

    1994-01-01

    This study was designed to evaluate the normal anatomy of the digital flexor tendon sheath using contrast radiography and diagnostic ultrasound. Iodinated contrast medium was injected into eight cadaver limbs and the limbs immediately frozen. Lateromedial and dorsopalmar/plantar radiographs were made. These limps were then cut transversely and proximal to distal radiographs of each slab were made. This cross sectional contrast methodology allowed the visualization of the relative size and shape of the superficial and deep digital flexor tendons as well as the potential space taken by effusions of the digital flexor tendon sheath. The second part of the study used twelve live animals with normal digital flexor tendon sheaths. Ultrasonographic measurement of the structures of the digital flexor tendon sheath at each level were compiled. This documented the ability of diagnostic ultrasound to image: 1) the superficial and deep digital flexor tendons, 2) the proximal and distal ring of the manica flexoria, 3) the straight and oblique sesamoidean ligaments, and 4) the mesotendinous attachments to the superficial and deep flexor tendons. Iodinated contrast medium was then injected into the digital flexor tendon sheath and the ultrasonography repeated. These images were compared with those obtained from contrast radiography and prosections of twenty normal limbs. The iodinated contrast medium enhanced sonographic imaging of the structures of the digital tendon sheath, particularly the abaxial borders of the superficial digital flexor tendon branches and the mesotendinous attachments to the superficial and deep digital flexor tendons

  17. Initial experience with visualizing hand and foot tendons by dual-energy computed tomography.

    Science.gov (United States)

    Deng, Kai; Sun, Cong; Liu, Cheng; Ma, Rui

    2009-01-01

    To assess the feasibility of visualizing hand and foot tendons by dual-energy computed tomography (CT). Twenty patients who suffered from hand or feet pains were scanned on dual-source CT (Definition, Forchheim, Germany) with dual-energy mode at tube voltages of 140 and 80 kV and a corresponding ratio of 1:4 between tube currents. The reconstructed images were postprocessed by volume rendering techniques (VRT) and multiplanar reconstruction (MPR). All of the suspected lesions were confirmed by surgery or follow-up studies. Twelve patients (total of 24 hands and feet, respectively) were found to be normal and the other eight patients (total of nine hands and feet, respectively) were found abnormal. Dual-energy techniques are very useful in visualizing tendons of the hands and feet, such as flexor pollicis longus tendon, flexor digitorum superficialis/profundus tendon, Achilles tendon, extensor hallucis longus tendon, and extensor digitorum longus tendon, etc. It can depict the whole shape of the tendons and their fixation points clearly. Peroneus longus tendon in the sole of the foot was not displayed very well. The distal ends of metacarpophalangeal joints with extensor digitoium tendon and extensor pollicis longus tendon were poorly shown. The lesions of tendons such as the circuitry, thickening, and adherence were also shown clearly. Dual-energy CT offers a new method to visualize tendons of the hand and foot. It could clearly display both anatomical structures and pathologic changes of hand and foot tendons.

  18. The prevalence of tenosynovitis of the interosseous tendons of the hand in patients with rheumatoid arthritis

    International Nuclear Information System (INIS)

    Rowbotham, Emma L.; Freeston, Jane E.; Emery, Paul; Grainger, Andrew J.

    2016-01-01

    The aim of this study was to establish the prevalence of tenosynovitis affecting the interosseous tendons of the hand in a rheumatoid arthritis (RA) population and to assess for association with metacarpophalangeal (MCP) joint synovitis, flexor tendon tenosynovitis or ulnar drift. Forty-four patients with RA underwent hand MRI along with 20 normal controls. Coronal 3D T1 VIBE sequences pre- and post-contrast were performed and reconstructed. The presence of interosseous tendon tenosynovitis was recorded alongside MCP joint synovitis, flexor tendon tenosynovitis and ulnar drift. Twenty-one (47.7 %) patients with RA showed interosseous tendon tenosynovitis. Fifty-two (14.8 %) interosseous tendons showed tenosynovitis amongst the RA patients. Interosseous tendon tenosynovitis was more commonly seen in association with adjacent MCP joint synovitis (p < 0.001), but nine MCP joints (5.1 %) showed adjacent interosseous tenosynovitis in the absence of joint synovitis. Interosseous tendon tenosynovitis was more frequently seen in fingers which also showed flexor tendon tenosynovitis (p < 0.001) and in patients with ulnar drift of the fingers (p = 0.01). Tenosynovitis of the hand interosseous tendons was found in 47.7 % of patients with RA. In the majority of cases this was adjacent to MCP joint synovitis; however, interosseous tendon tenosynovitis was also seen in isolation. (orig.)

  19. The prevalence of tenosynovitis of the interosseous tendons of the hand in patients with rheumatoid arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Rowbotham, Emma L. [Leeds Teaching Hospitals NHS Trust, Musculoskeletal Radiology Department, Leeds (United Kingdom); Freeston, Jane E. [Department of Rheumatology, Leeds Teaching Hospitals NHS Trust, Leeds (United Kingdom); Emery, Paul [University of Leeds, Arthritis Research UK, Leeds Musculoskeletal Biomedical Research Unit, LTHT Leeds Institute of Rheumatic Musculoskeletal Medicine, Leeds (United Kingdom); Grainger, Andrew J. [Leeds Teaching Hospitals NHS Trust, Musculoskeletal Radiology Department, Leeds (United Kingdom); Chapel Allerton Hospital, NIHR Leeds Musculoskeletal Biomedical Research Unit, Leeds (United Kingdom)

    2016-02-15

    The aim of this study was to establish the prevalence of tenosynovitis affecting the interosseous tendons of the hand in a rheumatoid arthritis (RA) population and to assess for association with metacarpophalangeal (MCP) joint synovitis, flexor tendon tenosynovitis or ulnar drift. Forty-four patients with RA underwent hand MRI along with 20 normal controls. Coronal 3D T1 VIBE sequences pre- and post-contrast were performed and reconstructed. The presence of interosseous tendon tenosynovitis was recorded alongside MCP joint synovitis, flexor tendon tenosynovitis and ulnar drift. Twenty-one (47.7 %) patients with RA showed interosseous tendon tenosynovitis. Fifty-two (14.8 %) interosseous tendons showed tenosynovitis amongst the RA patients. Interosseous tendon tenosynovitis was more commonly seen in association with adjacent MCP joint synovitis (p < 0.001), but nine MCP joints (5.1 %) showed adjacent interosseous tenosynovitis in the absence of joint synovitis. Interosseous tendon tenosynovitis was more frequently seen in fingers which also showed flexor tendon tenosynovitis (p < 0.001) and in patients with ulnar drift of the fingers (p = 0.01). Tenosynovitis of the hand interosseous tendons was found in 47.7 % of patients with RA. In the majority of cases this was adjacent to MCP joint synovitis; however, interosseous tendon tenosynovitis was also seen in isolation. (orig.)

  20. Extrusion of bone anchor suture following flexor digitorum profundus tendon avulsion injury repair.

    LENUS (Irish Health Repository)

    Tiong, William H C

    2011-09-01

    Flexor digitorum profundus (FDP) zone I tendon avulsion injury is traditionally repaired with a pullout suture technique. More recently, bone anchor sutures have been used as a viable alternative and have largely replaced areas in hand surgery where pullout suture technique was once required. To date, there have been very few complications reported related to bone anchor suture use in FDP tendon reattachment to the bone. We report a very unusual case of extrusion of bone anchor through the nailbed, 6 years after zone I FDP tendon avulsion injury repair and a brief review of literature.

  1. Neglected ruptured flexor carpi ulnaris tendon mimics a soft tissue tumor in the wrist.

    Science.gov (United States)

    Rau, Chi-Lun; Yen, Tze-Hsun; Wu, Lien-Chen; Huang, Yi-You; Jaw, Fu-Shan; Liou, Tsan-Hon

    2014-04-01

    A wrist mass is rarely caused by a ruptured tendon in the forearm. The common pathologies are ganglia, tendon tenosynovitis, and giant cell tumors of tendon sheaths. Less common causes are nerve sheath tumors, vascular lesions, or an accessory muscle belly. The authors investigated a case of neglected ruptured flexor carpi ulnaris tendon that mimics a mass in the wrist. To the authors' knowledge, this is the first case report in relevant literature. During investigation, the high-resolution musculoskeletal ultrasound suggested a soft tissue tumor or a ruptured flexor carpi ulnaris tendon. The magnetic resonance imaging scan indicated an accessory flexor carpi ulnaris muscle belly. The diagnosis of ruptured flexor carpi ulnaris tendon was confirmed by surgical exploration. This case indicates that ultrasound may be better suited than magnetic resonance imaging in evaluating a wrist mass for its accuracy, availability, and portability.

  2. [Reconstruction of chronic Achilles tendon rupture with flexor hallucis longus tendon harvested using a minimally invasive technique].

    Science.gov (United States)

    Miao, Xudong; Wu, Yongping; Tao, Huimin; Yang, Disheng

    2011-07-01

    To evaluate the effectiveness of flexor hallucis longus tendon harvested using a minimally invasive technique in reconstruction of chronic Achilles tendon rupture. Between July 2006 and December 2009, 22 patients (22 feet) with chronic Achilles tendon rupture were treated, including 16 males and 6 females with a median age of 48 years (range, 28-65 years). The disease duration was 27-1,025 days (median, 51 days). Twenty-one patients had hooflike movement's history and 1 patient had no obvious inducement. The result of Thompson test was positive in 22 cases. The score was 53.04 +/- 6.75 according to American Orthopedic Foot and Ankle Society (AOFAS) ankle and hindfoot score system. MRI indicated that the gap of the chronic Achilles tendon rupture was 4.2-8.0 cm. A 3 cm-long incision was made vertically in the plantar aspect of the midfoot and a 1 cm-long transverse incision was made in a plantar flexor crease at the base of the great toe to harvest flexor hallucis longus tendon. The flexor hallucis longus tendon was 10.5-13.5 cm longer from tuber calcanei to the end of the Achilles tendon, and then the tendon was fixed to the tuber calcanei using interface screws or anchor nail after they were woven to form reflexed 3-bundle and sutured. Wound healed by first intention in all patients and no early complication occurred. Twenty-two patients were followed up 12-42 months (mean, 16.7 months). At 12 months after operation, The AOFAS ankle and hindfoot score was 92.98 +/- 5.72, showing significant difference when compared with that before operation (t= -40.903, P=0.000). The results were excellent in 18 cases, good in 2 cases, and fair in 2 cases with an excellent and good rate of 90.9%. No sural nerve injury, posterior tibial nerve injury, plantar painful scar, medial plantar nerve injury, and lateral plantar nerve injury occurred. Chronic Achilles tendon rupture reconstruction with flexor hallucis longus tendon harvested using a minimally invasive technique offers a

  3. Comprehensive evaluation of finger flexor tendon entheseal soft tissue and bone changes by ultrasound can differentiate psoriatic arthritis and rheumatoid arthritis.

    Science.gov (United States)

    Tinazzi, Ilaria; McGonagle, Dennis; Zabotti, Alen; Chessa, Donatella; Marchetta, Antonio; Macchioni, Pierluigi

    2018-02-28

    To determine whether a detailed sonographic evaluation of the hand flexor tendon compartment could help differentiate between psoriatic arthritis (PsA) and rheumatoid arthritis (RA). Thirty-seven patients with PsA, 47 with RA and 10 healthy controls (HC) had flexor tendon (FT) compartment imaging of the dominant hand 2nd to 4th tendons using grey scale (GS) and power Doppler (PD) ultrasound (US) with evaluation for tenosynovitis, peri-tendinous lesions, soft tissue oedema and bony changes at FT insertions. 24/37 PsA and 19/47 RA cases had morning stiffness and 19/37 PsA and 10/47 RA had swollen and/or tender fingers. Tenosynovitis was more common in PsA (25/37) despite higher DAS28 scores in RA (25/37 versus 10/45; pthe insertional site was significantly more common in PsA (p=0.001). Considering a total inflammatory score per patient summing up the three modifications of the flexor tendon (tenosynovitis, peri-tendinous oedema and insertional enthesophytes) the difference between PsA and RA remained statistically significant (pthe growing body of literature that high resolution US of the hand FT compartment may help differentiate between RA and PsA, which needs assessment in the diagnostic setting.

  4. Effects of Smoking on Hand Tendon Repair: Scientific Study & Literature Review

    OpenAIRE

    Samona J; Samona S; Gilin M; Carwile D; Persons S; AG Dass

    2017-01-01

    Purpose: The clinical effect of smoking on after tendon repair in smokers vs non-smokers was investigated, via exploring effects on flexor and tendon repair, and incidence of wound complications. Methods: Retrospective review of patients treated by 1 orthopedic surgeon, fellowship trained in hand surgery, and 3 occupational therapists working together in 1 physical therapy institution. 56 patients (20 smokers and 36 non-smokers) with acute traumatic tendon lacerations, fixed via direct (end-t...

  5. Magnetic resonance imaging appearance of the flexor carpi radialis tendon after harvest in ligamentous reconstruction tendon interposition arthroplasty

    International Nuclear Information System (INIS)

    Beall, Douglas P.; Fish, Jon R.; Ritchie, Eric R.; Tran, Hoang N.; Ingari, John V.; Campbell, Scot E.; Grayson, David E.; Sanders, Timothy G.; Mundis, Gregory; Lehman, Thomas P.

    2006-01-01

    To determine whether the post-harvest magnetic resonance (MR) imaging appearance of flexor carpi radialis (FCR) tendons, harvested during ligamentous reconstruction tendon interposition (LRTI) of the thumb carpometacarpal (CMC) joint arthroplasty, is consistent with tendon regeneration. Operative reports and patient medical records for all patients undergoing LRTI arthroplasty between 1995 and 2003 at our institution were reviewed. MR images of the patients' forearms and wrists were obtained and interpreted by two musculoskeletal radiologists. Using the flexor carpi ulnaris (FCU) tendon as an internal standard, the extent of FCR tendon regeneration was expressed as a percentage by dividing the volume of regenerated FCR tendon by the volume of the FCU tendon. Fourteen patients who had the full thickness of the FCR tendon harvested and who were available for MR imaging were identified and included in the study. At least partial regeneration of the FCR tendon occurred in 11 of the 14 patients (79%). Of these, 2 patients (14%), demonstrated complete, or nearly complete regeneration. Partial regeneration of the FCR tendon was seen in 9 of the 14 patients (64%). In 3 patients (21%), there was no appreciable regeneration of the FCR tendon. Among patients who underwent full-thickness harvest of the FCR tendon for LRTI arthroplasty of the first CMC joint, the follow-up MR imaging appearance of the flexor carpi radialis tendon was consistent with tendon regeneration in 79% of those examined. (orig.)

  6. Anatomical Study of the Neurovascular in Flexor Hallucis Longus Tendon Transfers.

    Science.gov (United States)

    Mao, Haijiao; Dong, Wenwei; Shi, Zengyuan; Yin, Weigang; Xu, Dachuan; Wapner, Keith L

    2017-10-27

    The transfer of the flexor hallucis longus tendon or flexor digitorum longus tendon is frequently used for the treatment of posterior tibial tendon insufficiency or chronic Achilles tendinopathy. According to several anatomical studies, harvesting the flexor hallucis longus (FHL) tendon may cause nerve injury. Sixty-eight embalmed feet were dissected and anatomically classified to define the relationship between Henry's knot and the plantar nerves. Two different configurations were identified. In Pattern 1, which was observed in 64 specimens (94.1%), the distance between the medial plantar nerve and Henry's knot was 5.96 mm (range, 3.34 to 7.84, SD = 1.12). In Pattern 2, which was observed in 4 specimens (5.9%), there was no distance between the medial plantar nerve (MPN) and Henry's knot. No statistically significant difference was observed according to gender or side (p > 0.05). A retraction was performed to harvest the FHL through the posteromedial hindfoot incision using a single minimally invasive technique, and the medial and lateral plantar nerve lesions were scrupulously assessed. In conclusion, medial and lateral plantar nerve injuries did not occur more frequently, even after performing a single minimally invasive incision to harvest the FHL tendon, due to the large distance between the FHL tendon and the medial and lateral plantar nerves.

  7. In Vitro Comparison of Two Barbed Suture Configurations for Flexor Tendon Repair.

    Science.gov (United States)

    Engel, Jamie L; Gabra, Joseph N; Esterle, Andrew R; Lanzinger, William D; Elias, John J

    2017-12-01

    Purpose  The current study compares the strength of a previously studied technique for flexor tendon repair with barbed sutures to an experimental approach that aligns all the barbs to oppose distraction. Methods  Twelve flexor tendons from cadaveric specimens were mechanically tested following repair of simulated zone II tendon injuries. Two repair techniques utilizing barbed sutures were studied: the Marrero-Amadeo four-core barbed suture approach and the experimental configuration with all barbs on four cores opposing distraction. Maximum applied load at failure, that is, ultimate load, and 2-mm gap force were compared between the two repair techniques, both as raw values and after normalization to cross-sectional area of the intact tendon. Statistical testing was performed using t -tests and Mann-Whitney U -tests, where appropriate, with a significance level of 0.05. Results  The ultimate loads, raw (58.2 N) and normalized (4.8 N/mm 2 ), were significantly larger for the Marrero-Amadeo repair than the proposed experimental approach (35.6 N and 2.7 N/mm 2 ; p  barbs to oppose distraction does not improve strength of the repaired tendon. The Marrero-Amadeo technique was found to have superior strength for use in traumatic zone II flexor tendon injuries.

  8. The prevalence of tenosynovitis of the interosseous tendons of the hand in patients with rheumatoid arthritis.

    OpenAIRE

    Rowbotham, EL; Freeston, JE; Emery, P; Grainger, AJ

    2015-01-01

    AIM: The aim of this study was to establish the prevalence of tenosynovitis affecting the interosseous tendons of the hand in a rheumatoid arthritis (RA) population and to assess for association with metacarpophalangeal (MCP) joint synovitis, flexor tendon tenosynovitis or ulnar drift. METHODS: Forty-four patients with RA underwent hand MRI along with 20 normal controls. Coronal 3D T1 VIBE sequences pre- and post-contrast were performed and reconstructed. The presence of interosseous tendon t...

  9. The Fine Wire Technique for Flexor Tenolysis

    Science.gov (United States)

    Baltodano, Pablo A.; Weinberg, Maxene H.; Whipple, Lauren A.; Gemmiti, Amanda L.; Whipple, Richard E.

    2017-01-01

    Background: Flexor tenolysis surgery for flexor digitorum profundus and superficialis adhesions is a common procedure performed by hand surgeons. Releasing these adhered tendons can greatly improve hand function and improve quality of life. Recent evidence, however, has shown that the outcomes of tenolysis surgeries are often suboptimal and can result in relapsing adhesions or even tendon ruptures. Methods: This article describes a new technique with potential for reduced complication rates: The Fine Wire Technique for Flexor Tenolysis (FWT). Results: Following FWT, the patient detailed in this article had an excellent recovery of function and no complications: including tendon rupture, infection, hematomas, or any other complications. She reported a major improvement from her preoperative functionality and continues to have this level of success. The wire’s thinness allows for a swift tenolysis. Conclusions: The FWT is a new option available to the hand surgeon associated with good functional results. The wire is readily available to the clinician and is also inexpensive. PMID:29263961

  10. The Fine Wire Technique for Flexor Tenolysis.

    Science.gov (United States)

    Rosenblum, Matthew K; Baltodano, Pablo A; Weinberg, Maxene H; Whipple, Lauren A; Gemmiti, Amanda L; Whipple, Richard E

    2017-11-01

    Flexor tenolysis surgery for flexor digitorum profundus and superficialis adhesions is a common procedure performed by hand surgeons. Releasing these adhered tendons can greatly improve hand function and improve quality of life. Recent evidence, however, has shown that the outcomes of tenolysis surgeries are often suboptimal and can result in relapsing adhesions or even tendon ruptures. This article describes a new technique with potential for reduced complication rates: The Fine Wire Technique for Flexor Tenolysis (FWT). Following FWT, the patient detailed in this article had an excellent recovery of function and no complications: including tendon rupture, infection, hematomas, or any other complications. She reported a major improvement from her preoperative functionality and continues to have this level of success. The wire's thinness allows for a swift tenolysis. The FWT is a new option available to the hand surgeon associated with good functional results. The wire is readily available to the clinician and is also inexpensive.

  11. Effect of eccentric training on the plantar flexor muscle-tendon tissue properties.

    Science.gov (United States)

    Mahieu, Nele Nathalie; McNair, Peter; Cools, Ann; D'Haen, Caroline; Vandermeulen, Katrien; Witvrouw, Erik

    2008-01-01

    It has been shown that eccentric training can be effective in the rehabilitation of patients with Achilles tendonopathy. The mechanism behind these results is not clear. However, there is evidence that tendons are able to respond to repeated forces by altering their structure and composition, and, thus, their mechanical properties change. In this regard, the objective of the present study was to investigate whether eccentric training affects the mechanical properties of the plantar flexor's muscle-tendon tissue properties. Seventy-four healthy subjects were randomized into two groups: an eccentric training group and a control group. The eccentric training group performed a 6-wk eccentric training program for the calf muscles. Before and after this period, all subjects were evaluated for dorsiflexion range of motion using universal goniometry, passive resistive torque of the plantar flexors, and stiffness of the Achilles tendon. Passive resistive torque was measured during ankle dorsiflexion on an isokinetic dynamometer. Stiffness of the Achilles tendon was assessed using a dynamometer, in combination with ultrasonography. The results of the study reveal that the dorsiflexion range of motion was significantly increased only in the eccentric training group. The eccentric heel drop program also resulted in a significant decrease of the passive resistive torque of the plantar flexors (from 16.423 +/- 0.827 to 12.651 +/- 0.617 N.m). The stiffness of the Achilles tendon did not change significantly as a result of training. These findings provide evidence that an eccentric training program results in changes to some of the mechanical properties of the plantar flexor muscles. These changes were thought to be associated with modifications to structure rather than to stretch tolerance.

  12. Giant cell tumor of the tendon sheath of the hand - magnetic resonance image and orthopaedic treatment

    International Nuclear Information System (INIS)

    Kirova, G.; Monovska, T.; Jablanski, V.; Alexieva, K.; Velev, M.

    2009-01-01

    Giant cell tumour of the tendon sheath (GCT-TS), also known as localized nodular tenosynovitis, is a benign neoplasm that occurs dominantly on the digits. These tumours most commonly occur in patients aged 30-50 years and are associated with degenerative joint disease. GCT-TS usually arises from the synovium of tendon sheets, affecting interfalangeal joints of the hand, feet, ankle and knees. Magnetic Resonance Imaging is able to depict characteristic signal intensities and can accurately assess the tumor size and degree of extent around the phalanx. We present a case of a 36 years-old male patient with GCT-TS in the flexor tendon of his left second finger, diagnosed with Magnetic Resonance imaging. The mass was excised widely with preservation of the flexor tendon without recurrence. (authors)

  13. Ganglion of the Flexor Tendon Sheath at the A2 Pulley - Case Report

    Directory of Open Access Journals (Sweden)

    P Gunaseelan

    2015-03-01

    Full Text Available There are few reported cases of flexor tendon sheath ganglion arising from the A2 pulley. We report a case of a flexor tendon sheath ganglion in a 17-year old female who presented with pain, triggering and a swelling at the base of her right ring finger. During the excision biopsy, a ganglion measuring 0.5×0.8×0.4 cm in size was removed from the A2 pulley area.

  14. Serial superficial digital flexor tendon biopsies for diagnosing and monitoring collagenase-induced tendonitis in horses

    Directory of Open Access Journals (Sweden)

    José C. de Lacerda Neto

    2013-06-01

    Full Text Available The purpose of this investigation was to demonstrate the feasibility of a biopsy technique by performing serial evaluations of tissue samples of the forelimb superficial digital flexor tendon (SDFT in healthy horses and in horses subjected to superficial digital flexor tendonitis induction. Eight adult horses were evaluated in two different phases (P, control (P1 and tendonitis-induced (P2. At P1, the horses were subjected to five SDFT biopsies of the left forelimb, with 24 hours (h of interval. Clinical and ultrasonographic (US examinations were performed immediately before the tendonitis induction, 24 and 48 h after the procedure. The biopsied tendon tissues were analyzed through histology. P2 evaluations were carried out three months later, when the same horses were subjected to tendonitis induction by injection of bacterial collagenase into the right forelimb SDFT. P2 clinical and US evaluations, and SDFT biopsies were performed before, and after injury induction at the following time intervals: after 24, 48, 72 and 96 h, and after 15, 30, 60, 90, 120 and 150 days. The biopsy technique has proven to be easy and quick to perform and yielded good tendon samples for histological evaluation. At P1 the horses did not show signs of localised inflammation, pain or lameness, neither SDFT US alterations after biopsies, showing that the biopsy procedure per se did not risk tendon integrity. Therefore, this procedure is feasible for routine tendon histological evaluations. The P2 findings demonstrate a relation between the US and histology evaluations concerning induced tendonitis evolution. However, the clinical signs of tendonitis poorly reflected the microscopic tissue condition, indicating that clinical presentation is not a reliable parameter for monitoring injury development. The presented method of biopsying SDFT tissue in horses enables the serial collection of material for histological analysis causing no clinical signs and tendon damage seen

  15. A technique for introducing looped sutures in flexor tendon repair

    Directory of Open Access Journals (Sweden)

    Kamath B

    2006-01-01

    Full Text Available Stronger flexor tendon repairs facilitate early active motion therapy protocols. Core sutures using looped suture material provide 1 ½ to twice the strength of Kessler′s technique (with four strand and six strand Tsuge technique respectively. The technique is well-described and uses preformed looped sutures (supramid. This is not available in many countries and we describe a technique whereby looped sutures can be introduced in flexor tendon repair by the use of 23 G hypodermic needle and conventional 4.0 or 5.0 sutures. This is an alternative when the custom made preformed sutures are not available. This can be practiced in zone 3 to zone 5 repairs. Technical difficulties limit its use in zone 2 repairs.

  16. Digital flexor tendon contracture treated by tenectomy: different clinical presentations in three cats

    Directory of Open Access Journals (Sweden)

    Quentin Cabon

    2015-07-01

    Full Text Available Case series summary Three cats, Siamese or Siamese cross, were presented with a chronic thoracic limb weightbearing lameness. Previous anti-inflammatory administrations were unable to improve lameness consistently in the three cats. Two of the three cats had undergone onychectomy several years before presentation. A permanent flexion of the proximal interphalangeal joint of one or more digits, associated with a difficult and painful extension of the proximal interphalangeal joint, was noticed during orthopedic examination. A digital flexor tendon contracture was suspected and confirmed with radiographic examination. Surgical exploration was then performed. For all cats, treatment consisted of a tenectomy or tenotomy of the superficial and deep digital flexor tendons in order to release the contracture. The three cats responded well to the surgical treatment and became sound around 2–4 weeks after surgery. Relevance and novel information Digital flexor tendon contracture is rarely reported as a cause of lameness in cats. It should be considered in a differential diagnosis of feline lameness whenever onychectomy has been performed in the past. The precise etiology that explains this tendon contracture is unknown, but trauma or breed predisposition could represent potential causes.

  17. Presence of a long accessory flexor tendon of the toes in surgical treatment for tendinopathy of the insertion of the calcaneal tendon: case report

    Directory of Open Access Journals (Sweden)

    Nelson Pelozo Gomes Júnior

    2016-02-01

    Full Text Available ABSTRACT The presence of accessory tendons in the foot and ankle needs to be recognized, given that depending on their location, they may cause disorders relating either to pain processes or to handling of the surgical findings. We describe the presence of an accessory flexor tendon of the toes, seen in surgical exposure for transferring the long flexor tendon of the hallux to the calcaneus, due to the presence of a disorder of tendinopathy of the insertion of the calcaneal tendon in association with Haglund's syndrome.

  18. The role of ultrasound in the management of flexor tendon injuries.

    Science.gov (United States)

    Jeyapalan, K; Bisson, M A; Dias, J J; Griffin, Y; Bhatt, R

    2008-08-01

    The use of ultrasound scanning to establish tendon pathologies was assessed retrospectively in 17 patients in 18 digits. The ultrasound scan demonstrated four patterns: (1) normal intact tendons in four, (2) ruptured tendons in three, (3) tendons in continuity but attenuated in five and (4) tendons in continuity but thickened with fibrosis and decreased movement representing adhesions in five patients. Surgery was undertaken in only three cases, confirming the ultrasound diagnosis in two. Surgery was offered to all three patients with ruptures but was declined by two. Ultrasound imaging helped to avoid surgery in 14 cases by excluding flexor tendon re-ruptures. This allowed on-going mobilisation, leading to recovery of function.

  19. Ultrasonographic Evaluation of Zone II Partial Flexor Tendon Lacerations of the Fingers: A Cadaveric Study.

    Science.gov (United States)

    Kazmers, Nikolas H; Gordon, Joshua A; Buterbaugh, Kristen L; Bozentka, David J; Steinberg, David R; Khoury, Viviane

    2018-04-01

    Accurate assessment of zone II partial flexor tendon lacerations in the finger is clinically important. Surgical repair is recommended for lacerations of greater than 50% to 60%. Our goal was to evaluate ultrasonographic test characteristics and accuracy in identifying partial flexor tendon lacerations in a cadaveric model. From fresh-frozen above-elbow human cadaveric specimens, 32 flexor digitorum profundus tendons were randomly selected to remain intact or receive low- or high-grade lacerations involving 10% to 40% and 60% to 90% of the radioulnar width within Verdan Zone II, respectively. Static and dynamic ultrasonography using a linear array 14-MHz transducer was performed by a blinded musculoskeletal radiologist. Sensitivities, specificities, and other standard test performance metrics were calculated. Actual and measured percentages of tendon laceration were compared by the paired t test. After randomization, 24 tendons were lacerated (12 low- and 12 high-grade), whereas 8 remained intact. The sensitivity and specificity in detecting the presence versus absence of a partial laceration were 0.54 and 0.75, respectively, with positive and negative likelihood ratio values of 2.17 and 0.61. For low-grade lacerations, the sensitivity and specificity were 0.25 and 0.85, compared to 0.83 and 0.85 for high-grade lacerations. Ultrasonography underestimated the percentage of tendon involvement by a mean of 18.1% for the study population as a whole (95% confidence interval, 9.0% to 27.2%; P partial flexor digitorum profundus lacerations in a cadaveric model. © 2017 by the American Institute of Ultrasound in Medicine.

  20. Clinical Results of Flexor Tendon Repair in Zone II Using a six Strand Double Loop Technique.

    Science.gov (United States)

    Savvidou, Christiana; Tsai, Tsu-Min

    2015-06-01

    The purpose of this study is to report the clinical results after repair of flexor tendon zone II injuries utilizing a 6-strand double-loop technique and early post-operative active rehabilitation. We retrospectively reviewed 22 patients involving 51 cases with zone II flexor tendon repair using a six strand double loop technique from September 1996 to December 2012. Most common mechanism of injuries was sharp lacerations (86.5 %). Tendon injuries occurred equally in manual and non-manual workers and were work-related in 33 % of the cases. The Strickland score for active range of motion (ROM) postoperatively was excellent and good in the majority of the cases (81 %). The rupture rate was 1.9 %. The six strand double loop technique for Zone II flexor tendon repair leads to good and excellent motion in the majority of patients and low re- rupture rate. It is clinically effective and allows for early postoperative active rehabilitation.

  1. The range of excursion of flexor tendons in Zone V: a comparison of active vs passive flexion mobilisation regimes.

    LENUS (Irish Health Repository)

    Panchal, J

    1997-10-01

    A number of early postoperative mobilisation regimes have been developed in an attempt to increase tendon excursion and gliding and thereby reduce formation of adhesions following repair of flexor tendons. Early active flexion mobilisation regimes are becoming more popular, and have replaced early passive flexion regimes in many centres. The aim of the present study was: (a) to determine the range of excursion of flexor tendons in Zone V, and (b) to compare the excursion ranges between active (Belfast) and passive (modified Duran) flexion mobilisation regimes postoperatively. This was done (a) in two cadavers, and (b) in two patients intraoperatively, and postoperatively at 10 days, 3 weeks and 6 weeks. With passive flexion, the mean tendon excursion in Zone V in cadavers was 1 mm for flexor digitorum superficialis (FDS), flexor digitorum profundus (FDP) and flexor pollicis longus (FPL) tendons respectively. With simulated active flexion, the mean tendon excursion was 14 mm, 10 mm and 11 mm respectively. The mean tendon excursion in clinical cases intraoperatively following passive flexion was 2 mm for FDS, FDP and FPL respectively; following simulated active flexion it was 10 mm, 11 mm and 11 mm for FDS, FDP and FPL respectively. On the tenth day following repair, the mean excursions of FDS, FDP and FPL were 1 mm, 4 mm and 4 mm on passive flexion as compared to 3 mm, 10 mm and 12 mm on active flexion respectively. Three weeks postoperatively, the mean excursions of FDS, FDP and FPL tendons were 1 mm, 2 mm and 1 mm on passive flexion as compared to 5 mm, 15 mm on active flexion respectively. Six weeks postoperatively, the mean excursions of FDS, FDP and FPL tendons were 9 mm, 7 mm and 4 mm on passive flexion as compared to 12 mm, 33 mm and 20 mm on active flexion respectively. These results demonstrate an increased excursion of repaired flexor tendons in Zone V following an active flexion mobilisation regime as compared to a passive flexion mobilisation regime.

  2. Four-Strand Core Suture Improves Flexor Tendon Repair Compared to Two-Strand Technique in a Rabbit Model

    Directory of Open Access Journals (Sweden)

    Alice Wichelhaus

    2016-01-01

    Full Text Available Introduction. This study was designed to investigate the influence of the amount of suture material on the formation of peritendinous adhesions of intrasynovial flexor tendon repairs. Materials and Methods. In 14 rabbits, the flexor tendons of the third and the fourth digit of the right hind leg were cut and repaired using a 2- or 4-strand core suture technique. The repaired tendons were harvested after three and eight weeks. The range of motion of the affected toes was measured and the tendons were processed histologically. The distance between the transected tendon ends, the changes in the peritendinous space, and cellular and extracellular inflammatory reaction were quantified by different staining. Results. A 4-strand core suture resulted in significantly less gap formation. The 2-strand core suture showed a tendency to less adhesion formation. Doubling of the intratendinous suture material was accompanied by an initial increase in leukocyte infiltration and showed a greater amount of formation of myofibroblasts. From the third to the eighth week after flexor tendon repair, both the cellular and the extracellular inflammation decreased significantly. Conclusion. A 4-strand core suture repair leads to a significantly better tendon healing process with less diastasis between the sutured tendon ends despite initially pronounced inflammatory response.

  3. Systemic EP4 Inhibition Increases Adhesion Formation in a Murine Model of Flexor Tendon Repair.

    Directory of Open Access Journals (Sweden)

    Michael B Geary

    Full Text Available Flexor tendon injuries are a common clinical problem, and repairs are frequently complicated by post-operative adhesions forming between the tendon and surrounding soft tissue. Prostaglandin E2 and the EP4 receptor have been implicated in this process following tendon injury; thus, we hypothesized that inhibiting EP4 after tendon injury would attenuate adhesion formation. A model of flexor tendon laceration and repair was utilized in C57BL/6J female mice to evaluate the effects of EP4 inhibition on adhesion formation and matrix deposition during flexor tendon repair. Systemic EP4 antagonist or vehicle control was given by intraperitoneal injection during the late proliferative phase of healing, and outcomes were analyzed for range of motion, biomechanics, histology, and genetic changes. Repairs treated with an EP4 antagonist demonstrated significant decreases in range of motion with increased resistance to gliding within the first three weeks after injury, suggesting greater adhesion formation. Histologic analysis of the repair site revealed a more robust granulation zone in the EP4 antagonist treated repairs, with early polarization for type III collagen by picrosirius red staining, findings consistent with functional outcomes. RT-PCR analysis demonstrated accelerated peaks in F4/80 and type III collagen (Col3a1 expression in the antagonist group, along with decreases in type I collagen (Col1a1. Mmp9 expression was significantly increased after discontinuing the antagonist, consistent with its role in mediating adhesion formation. Mmp2, which contributes to repair site remodeling, increases steadily between 10 and 28 days post-repair in the EP4 antagonist group, consistent with the increased matrix and granulation zones requiring remodeling in these repairs. These findings suggest that systemic EP4 antagonism leads to increased adhesion formation and matrix deposition during flexor tendon healing. Counter to our hypothesis that EP4 antagonism

  4. A new barbed device for repair of flexor tendons.

    LENUS (Irish Health Repository)

    Hirpara, K M

    2012-02-01

    We split 100 porcine flexor tendons into five groups of 20 tendons for repair. Three groups were repaired using the Pennington modified Kessler technique, the cruciate or the Savage technique, one using one new device per tendon and the other with two new devices per tendon. Half of the tendons received supplemental circumferential Silfverskiold type B cross-stitch. The repairs were loaded to failure and a record made of their bulk, the force required to produce a 3 mm gap, the maximum force applied before failure and the stiffness. When only one device was used repairs were equivalent to the Pennington modified Kessler for all parameters except the force to produce a 3 mm gap when supplemented with a circumferential repair, which was equivalent to the cruciate. When two devices were used the repair strength was equivalent to the cruciate repair, and when the two-device repair was supplemented with a circumferential suture the force to produce a 3 mm gap was equivalent to that of the Savage six-strand technique.

  5. Pyogenic Flexor Tenosynovitis in an Infant

    Directory of Open Access Journals (Sweden)

    James I. Gragg

    2017-03-01

    Full Text Available Pyogenic flexor tenosynovitis is a rare, though well known infectious process of the flexor tendon sheath of the hand. This condition is generally diagnosed in adults by the observance of the four Kanavel signs. Application of the Kanavel signs to diagnosis in the pediatric population, however, is of unknown utility. We present the case of a 13-month-old male with pyogenic flexor tenosynovitis who presented with all four of the Kanavel signs.

  6. Comparing Biomechanical Properties, Repair Times, and Value of Common Core Flexor Tendon Repairs.

    Science.gov (United States)

    Chauhan, Aakash; Schimoler, Patrick; Miller, Mark C; Kharlamov, Alexander; Merrell, Gregory A; Palmer, Bradley A

    2018-05-01

    The aim of the study was to compare biomechanical strength, repair times, and repair values for zone II core flexor tendon repairs. A total of 75 fresh-frozen human cadaveric flexor tendons were harvested from the index through small finger and randomized into one of 5 repair groups: 4-stranded cross-stitch cruciate (4-0 polyester and 4-0 braided suture), 4-stranded double Pennington (2-0 knotless barbed suture), 4-stranded Pennington (4-0 double-stranded braided suture), and 6-stranded modified Lim-Tsai (4-0 looped braided suture). Repairs were measured in situ and their repair times were measured. Tendons were linearly loaded to failure and multiple biomechanical values were measured. The repair value was calculated based on operating room costs, repair times, and suture costs. Analysis of variance (ANOVA) and Tukey post hoc statistical analysis were used to compare repair data. The braided cruciate was the strongest repair ( P > .05) but the slowest ( P > .05), and the 4-stranded Pennington using double-stranded suture was the fastest ( P > .05) to perform. The total repair value was the highest for braided cruciate ( P > .05) compared with all other repairs. Barbed suture did not outperform any repairs in any categories. The braided cruciate was the strongest of the tested flexor tendon repairs. The 2-mm gapping and maximum load to failure for this repair approached similar historical strength of other 6- and 8-stranded repairs. In this study, suture cost was negligible in the overall repair cost and should be not a determining factor in choosing a repair.

  7. Evidence Supporting Intralesional Stem Cell Therapy to Improve Equine Flexor Tendon Healing

    Directory of Open Access Journals (Sweden)

    Sushmitha Durgam

    2017-01-01

    Full Text Available Clinical bottom lineCurrent experimental evidence suggests that intralesional stem cell administration improves the histological characteristics and matrix organisation of healing equine superficial digital flexor tendons (SDFT; however, the clinical relevance of these findings are not clear. Current case-based evidence suggests that cell-based therapies improve the quality of tendon healing and reduce the recurrence rates of SDFT injuries but the lack of any randomised, controlled prospective studies with function-based outcomes is still concerning, given the widespread advocacy for and use of ‘stem cell’ therapies for the treatment of equine tendon injuries. 

  8. Gross and histological evaluation of early lesions of navicular bone and deep digital flexor tendon in horses

    Directory of Open Access Journals (Sweden)

    Komosa Marcin

    2014-03-01

    Full Text Available The study aimed at evaluation of pathological lesions on flexor surface of navicular bone and deep digital flexor tendon in horses graded in standard X-ray examination as 2 (fair. The evaluation was performed on fifteen horses (6-9 years of age. Analysis procedure involved examining navicular bones on X-ray pictures, post-slaughter preparation of navicular bones from the hoof capsule, macroscopic evaluation of fibrocartilage on flexor surface, and analysis of histologic preparations. In horses with navicular bones graded as 2, early pathological changes have already developed, even if such horses were not lame. The pathological changes included fibrillation and disruption of deep digital flexor tendon surface, loss of fibrocartillage in sagittal ridge area of navicular bone, thinning of subchondral bone on its flexor surface, and fibromyxoid changes in chondroid matrix. In terms of clinical relevance, more studies are needed to understand the sequence of changes in a better way.

  9. Lateral luxation of the superficial digital flexor tendon from the calcaneal tuber in two horses

    International Nuclear Information System (INIS)

    Meagher, D.M.; Aldrete, A.V.

    1989-01-01

    Lateral luxation of the superficial digital flexor tendon from the calcaneal tuber occurs in horses as a result of tearing or rupture of the medial retinaculum of the tendon. This report describes the repair of this condition in 2 Thoroughbred race horses, using a surgical technique in which 2 cancellous bone screws were placed in the calcaneus lateral to the tendon, along with suturing the medial retinaculum

  10. Freeze-dried allograft-mediated gene or protein delivery of growth and differentiation factor 5 reduces reconstructed murine flexor tendon adhesions

    DEFF Research Database (Denmark)

    Svensson, Sys Hasslund; Dadali, Tulin; Ulrich-Vinther, Michael

    2014-01-01

    reverse transcription polymerase chain reaction (RT-PCR), enzyme-linked immunosorbent assay (ELISA), and in vivo bioluminescent imaging. We then reconstructed flexor digitorum longus (FDL) tendons of the mouse hindlimb with allografts loaded with low and high doses of recombinant GDF-5 protein and r......Advances in allograft processing have opened new horizons for clinical adaptation of flexor tendon allografts as delivery scaffolds for antifibrotic therapeutics. Recombinant adeno-associated-virus (rAAV) gene delivery of the growth and differentiation factor 5 (GDF-5) has been previously...... associated with antifibrotic effects in a mouse model of flexor tendoplasty. In this study, we compared the effects of loading freeze-dried allografts with different doses of GDF-5 protein or rAAV-Gdf5 on flexor tendon healing and adhesions. We first optimized the protein and viral loading parameters using...

  11. Cyclic Testing of the 6-Strand Tang and Modified Lim-Tsai Flexor Tendon Repair Techniques.

    Science.gov (United States)

    Kang, Gavrielle Hui-Ying; Wong, Yoke-Rung; Lim, Rebecca Qian-Ru; Loke, Austin Mun-Kitt; Tay, Shian-Chao

    2018-03-01

    In this study, we compared the Tang repair technique with the 6-strand modified Lim-Tsai repair technique under cyclic testing conditions. Twenty fresh-frozen porcine flexor tendons were randomized into 2 groups for repair with either the modified Lim-Tsai or the Tang technique using Supramid 4-0 core sutures and Ethilon 6-0 epitendinous running suture. The repaired tendons were subjected to 2 stage cyclic loading. The survival rate and gap formation at the repair site were recorded. Tendons repaired by the Tang technique achieved an 80% survival rate. None of the modified Lim-Tsai repairs survived. The mean gap formed at the end of 1000 cycles was 1.09 mm in the Tang repairs compared with 4.15 mm in the modified Lim-Tsai repairs. The Tang repair is biomechanically stronger than the modified Lim-Tsai repair under cyclic loading. The Tang repair technique may exhibit a higher tolerance for active mobilization after surgery with less propensity for gap formation. Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  12. Accessory muscle of the flexor digitorum superficialis and its clinical implications

    Directory of Open Access Journals (Sweden)

    Edie Benedito Caetano

    Full Text Available ABSTRACT Anatomical variations of the flexor digitorum superficialis (FDS muscle and tendon unit are frequently reported by anatomists and clinicians. Anatomical muscle variations of the FDS and its tendons may include variations of muscle belly, presence of accessory or duplicate tendons, abnormal tendon connections, and absence of muscle or tendon components. Such variations may or may not have clinical implications. This report presents a case not described previously: a unilateral accessory muscle of the flexor digitorum superficialis which was connected by a thick tendon to the flexor digitorum superficialis muscle; it was directed proximally to the insertion of the medial epicondyle of the humerus, next to the superficialis head of the pronator teres muscle. The belly of the accessory muscle was positioned anterior to the median and anterior interosseous nerve. This anatomical variation is known as type V in the classification of Elliot et al. The knowledge of these anatomical variations helps hand surgeons interpret the clinical examination, particularly in the evaluation of patients who have suffered tendon injuries or show sign s of possible peripheral nerve entrapment.

  13. Effect of wrist and interphalangeal thumb movement on zone T2 flexor pollicis longus tendon tension in a human cadaver model.

    Science.gov (United States)

    Rappaport, Patricia O; Thoreson, Andrew R; Yang, Tai-Hua; Reisdorf, Ramona L; Rappaport, Stephen M; An, Kai-Nan; Amadio, Peter C

    2015-01-01

    Therapy after flexor pollicis longus (FPL) repair typically mimics finger flexor management, but this ignores anatomic and biomechanical features unique to the FPL. We measured FPL tendon tension in zone T2 to identify biomechanically appropriate exercises for mobilizing the FPL. Eight human cadaver hands were studied to identify motions that generated enough force to achieve FPL movement without exceeding hypothetical suture strength. With the carpometacarpal and metacarpophalangeal joints blocked, appropriate forces were produced for both passive interphalangeal (IP) motion with 30° wrist extension and simulated active IP flexion from 0° to 35° with the wrist in the neutral position. This work provides a biomechanical basis for safely and effectively mobilizing the zone T2 FPL tendon. Our cadaver study suggests that it is safe and effective to perform early passive and active exercise to an isolated IP joint. NA. Copyright © 2015 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  14. Flexor tendon repair with a knotless, bidirectional barbed suture: an in vivo biomechanical analysis.

    Science.gov (United States)

    Maddox, Grady E; Ludwig, Jonathan; Craig, Eric R; Woods, David; Joiner, Aaron; Chaudhari, Nilesh; Killingsworth, Cheryl; Siegal, Gene P; Eberhardt, Alan; Ponce, Brent

    2015-05-01

    To compare and analyze biomechanical properties and histological characteristics of flexor tendons either repaired by a 4-strand modified Kessler technique or using barbed suture with a knotless repair technique in an in vivo model. A total of 25 chickens underwent surgical transection of the flexor digitorum profundus tendon followed by either a 4-strand Kessler repair or a knotless repair with barbed suture. Chickens were randomly assigned to 1 of 3 groups with various postoperative times to death. Harvested tendons were subjected to biomechanical testing or histologic analysis. Harvested tendons revealed failures in 25% of knotless repairs (8 of 32) and 8% of 4-strand Kessler repairs (2 of 24). Biomechanical testing revealed no significant difference in tensile strength between 4-strand Kessler and barbed repairs; however, this lack of difference may be attributed to lower statistical power. We noted a trend toward a gradual decrease in strength over time for barbed repairs, whereas we noticed the opposite for the 4-strand Kessler repairs. Mode of failure during testing differed between repair types. The barbed repairs tended toward suture breakage as opposed to 4-strand Kessler repairs, which demonstrated suture pullout. Histological analysis identified no difference in the degree of inflammation or fibrosis; however, there was a vigorous foreign body reaction around the 4-strand Kessler repair and no such response around the barbed repairs. In this model, knotless barbed repairs trended toward higher in vivo failure rates and biomechanical inferiority under physiologic conditions, with each repair technique differing in mode of failure and respective histologic reaction. We are unable to recommend the use of knotless barbed repair over the 4-strand modified Kessler technique. For the repair techniques tested, surgeons should prefer standard Kessler repairs over the described knotless technique with barbed suture. Copyright © 2015 American Society for Surgery

  15. Nickel-titanium wire as a flexor tendon suture material: an ex vivo study.

    Science.gov (United States)

    Karjalainen, T; Göransson, H; Viinikainen, A; Jämsä, T; Ryhänen, J

    2010-07-01

    Nickel-titanium shape memory alloy (NiTi) is a new suture material that is easy to handle, is strong, and biocompatible. The purpose of this study was to evaluate the material properties and biomechanical behaviour of 150 microm and 200 microm NiTi wires in flexor tendon repair. Braided polyester (4-0 Ethibond) was used as control. Fifty fresh-frozen porcine flexor tendons were repaired using the Pennington modification of the Kessler repair or a double Kessler technique. NiTi wires were stiffer and reached higher tensile strength compared to braided polyester suture. Repairs with 200 microm NiTi wire had a higher yield force, ultimate force and better resistance to gapping than 4-0 braided polyester repairs. Repairs made with 200 microm NiTi wire achieved higher stiffness and ultimate force than repairs made with 150 microm NiTi wire.

  16. Tuberculous flexor tenosynovitis of the hand

    OpenAIRE

    Mohamed Ali Sbai; Sofien Benzarti; Monia Boussen; Riadh Maalla

    2015-01-01

    Tuberculosis is a major public health problem in developing countries. Flexor tenosynovitis of the fingers constitutes an exceptional tuberculosis localization (Gabl et al., 1997; Senda et al., 2011) [1],[2]. Unusual presentations, such as tuberculous tenosynovitis, often go undetected and are associated with a diagnostic and therapeutic delay, especially when bacteriological research proves to be negative. Here, we report a case of tuberculous flexor tenosynovitis of the hand.

  17. An age-related study of morphology and cross-link composition of collagen fibrils in the digital flexor tendons of young thoroughbred horses.

    Science.gov (United States)

    Patterson-Kane, J C; Parry, D A; Birch, H L; Goodship, A E; Firth, E C

    1997-01-01

    The superficial digital flexor tendon is the most commonly injured tendon in the racing Thoroughbred. Despite the clinical significance of this structure, only limited data exist regarding normal age-related morphology of the tensile units, the collagen fibrils. The age at which these collagen fibrils become mature in composition and structure may be of importance. Consequently, the association of age and collagen fibril crosslink composition, diameter distribution and crimp morphology in the superficial and deep digital flexor tendons of Thoroughbreds up to and including three years of age has been studied. Replacement of immature crosslinks, peaking of the collagen fibril mass-average diameter and collagen fibril index, and stabilization of collagen crimp morphology changes supported the hypothesis that both digital flexor tendons become mature in structure by two years of age.

  18. Using of Tendinous Plasty in Treatment of Patients with Flexor Tendons of 2–5 Fingers Injury in “Critical” Zone

    Directory of Open Access Journals (Sweden)

    S.I. Kireev

    2009-06-01

    Full Text Available Injury of both superficial and deep tendons of fingers flexors needs to carry out tendinous plasty with excision of distal part of superficial flexor muscle tendon. Use of length measuring method for tendinous transplant allows us to avoid the flexion contracture in future and appearance of functional insufficiency of flexion during postoperative period and rehabilitation of patient.

  19. The use of a cognitive task analysis-based multimedia program to teach surgical decision making in flexor tendon repair.

    Science.gov (United States)

    Luker, Kali R; Sullivan, Maura E; Peyre, Sarah E; Sherman, Randy; Grunwald, Tiffany

    2008-01-01

    The aim of this study was to compare the surgical knowledge of residents before and after receiving a cognitive task analysis-based multimedia teaching module. Ten plastic surgery residents were evaluated performing flexor tendon repair on 3 occasions. Traditional learning occurred between the first and second trial and served as the control. A teaching module was introduced as an intervention between the second and third trial using cognitive task analysis to illustrate decision-making skills. All residents showed improvement in their decision-making ability when performing flexor tendon repair after each surgical procedure. The group improved through traditional methods as well as exposure to our talk-aloud protocol (P > .01). After being trained using the cognitive task analysis curriculum the group displayed a statistically significant knowledge expansion (P multimedia surgical curriculum instruction achieved greater command of problem solving and are better equipped to make correct decisions in flexor tendon repair.

  20. Flexor tendon repair: a comparative study between a knotless barbed suture repair and a traditional four-strand monofilament suture repair.

    LENUS (Irish Health Repository)

    Joyce, C W

    2014-01-01

    We compared the tensile strength of a novel knotless barbed suture method with a traditional four-strand Adelaide technique for flexor tendon repairs. Forty fresh porcine flexor tendons were transected and randomly assigned to one of the repair groups before repair. Biomechanical testing demonstrated that the tensile strengths between both tendon groups were very similar. However, less force was required to create a 2 mm gap in the four-strand repair method compared with the knotless barbed technique. There was a significant reduction in the cross-sectional area in the barbed suture group after repair compared with the Adelaide group. This would create better gliding within the pulley system in vivo and could decrease gapping and tendon rupture.

  1. Amputation of finger by horse bite with complete avulsion of both flexor tendons.

    Science.gov (United States)

    Koren, Lior; Stahl, Shalom; Rovitsky, Alexey; Peled, Eli

    2011-08-08

    Amputation of fingers with tendon avulsion occurs through a traction injury, and most occur through a ring avulsion mechanism. Usually the flexor digitorum profundus is torn out with the amputated finger. Replantation usually is recommended only when the amputation is distal to the flexor digitorum superficialis insertion. Animal bites are relatively common, with a decreasing order of frequency of dogs, cats, and humans. Horse bites are relatively infrequent but are associated with crush injuries and tissue loss when they occur. This article describes a 23-year-old man with amputation of his middle finger at the level of the proximal phalanx after being bitten by a horse. The amputated stump was avulsed with the middle finger flexor digitorum profundus and flexor digitorum superficialis torn from the muscle-tendon junction from approximately the middle of the forearm. The patient had no other injuries, and he was able to move his other 4 fingers with only mild pain. As the amputated digit was not suitable for replantation, the wound was irrigated and debrided. The edges of the phalanx were trimmed, and the edges of the wound were sutured. Tetanus toxoid and rabies vaccine were administered, along with intravenous amoxicillin and clavulanic acid. The patient was discharged from the hospital 2 days later, with no sign of infection of the wound or compartment syndrome of the forearm. This case demonstrates the weakest point in the myotendinous junction and emphasizes the importance of a careful physical examination in patients with a traumatic amputation. Copyright 2011, SLACK Incorporated.

  2. The effect of a collagen-elastin matrix on adhesion formation after flexor tendon repair in a rabbit model.

    Science.gov (United States)

    Wichelhaus, Dagmar Alice; Beyersdoerfer, Sascha Tobias; Gierer, Philip; Vollmar, Brigitte; Mittlmeier, Th

    2016-07-01

    The outcome of flexor tendon surgery is negatively affected by the formation of adhesions which can occur during the healing of the tendon repair. In this experimental study, we sought to prevent adhesion formation by wrapping a collagen-elastin scaffold around the repaired tendon segment. In 28 rabbit hind legs, the flexor tendons of the third and fourth digits were cut and then repaired using a two-strand suture technique on the fourth digit and a four-strand technique on the third digit. Rabbits were randomly assigned to study and control groups. In the control group, the operation ended by closing the tendon sheath and the skin. In the study group, a collagen-elastin scaffold was wrapped around the repaired tendon segment in both digits. After 3 and 8 weeks, the tendons were harvested and processed histologically. The range of motion of the digits and the gap formation between the repaired tendon ends were measured. The formation of adhesions, infiltration of leucocytes and extracellular inflammatory response were quantified. At the time of tendon harvesting, all joints of the operated toes showed free range of motion. Four-strand core sutures lead to significantly less diastasis between the repaired tendon ends than two-strand core suture repairs. The collagen-elastin scaffold leads to greater gapping after 3 weeks compared to the controls treated without the matrix. Within the tendons treated with the collagen-elastin matrix, a significant boost of cellular and extracellular inflammation could be stated after 3 weeks which was reflected by a higher level of CAE positive cells and more formation of myofibroblasts in the αSMA stain in the study group. The inflammatory response subsided gradually and significantly until the late stage of the study. Both the cellular and extracellular inflammatory response was emphasized with the amount of material used for the repair. The use of a collagen-elastin matrix cannot be advised for the prevention of adhesion

  3. MRI findings in Kirner deformity: normal insertion of the flexor digitorum profundus tendon without soft-tissue enhancement

    International Nuclear Information System (INIS)

    Lee, Jaejoon; Ahn, Joong Kyong; Koh, Eun-Mi; Cha, Hoon-Suk; Choi, Sang-Hee

    2010-01-01

    Kirner deformity is characterized by volar and radial incurvature of the distal phalanx of the 5th finger. A proposed causative mechanism includes abnormal distal insertion of the flexor digitorum profundus tendon along the volar surface of the distal phalanx of the 5th finger. A chronic inflammatory process or altered vascularisation of the soft tissues has also been suggested as the underlying causative mechanism based on MRI findings. We present a teenage boy with Kirner deformity, along with supplementary imaging of his father who also has the deformity, to illustrate MRI findings that dispute the above hypotheses. MRI in both son and father show normal insertion of the deep flexor tendon and no signs of inflammation. (orig.)

  4. Vascular abnormalities of the distal deep digital flexor tendon in 8 draught horses identified on histological examination.

    Science.gov (United States)

    Crişan, Melania Ioana; Damian, Aurel; Gal, Adrian; Miclăuş, Viorel; Cernea, Cristina L; Denoix, Jean-Marie

    2013-08-01

    The purpose of this study was to provide a detailed description of the vascular changes in the distal part of deep digital flexor tendon (DDFT). Eight isolated forelimbs were collected from 8 horses with DDF tendinopathy diagnosed post-mortem by ultrasound and gross anatomopathological examination. The samples were fixed in 10% neutral buffered formalin, softened in 4% phenol and dehydrated with ethylic alcohol. Goldner's Trichrome staining method was used. The histopathological examination revealed vascular proliferation associated with structural disorders of blood vessels. Angiogenesis, fibroplasia and consecutive hypertrophy of the vascular wall with or without vascular occlusion were the most common findings. Other histopathological findings were: endothelial cell edema, progressive metaplasia from squamous to cubic cells, vascular wall hyalinization, endothelial cells apoptosis/necrosis and endothelial desquamation. These results demonstrated damage of the distal deep digital flexor tendon vasculature which may progressively alter the structural integrity of the tendon and contribute to degenerative lesions. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Enhanced MR imaging of tenosynovitis of hand and wrist in inflammatory arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Tehranzadeh, J.; Ashilyan, O.; Anavim, A.; Tramma, S. [Univ. of California, Orange (United States). Dept. of Radiological Sciences

    2006-11-15

    The purpose of this study is to describe the appearance of tenosynovitis in various tendon groups in the wrist and hand and to compare MR enhanced and non-enhanced imaging evaluation of tenosynovitis of hand and wrist in inflammatory arthritis. We reviewed 72 MRI studies of hands and wrists, including coronal, axial and sagittal images in 30 consecutive patients with inflammatory arthritis and tenosynovitis. We compared the degree of synovitis on T2-weighted vs contrast-enhanced T1-weighted images, using a predetermined scale. We also measured the extent of tenosynovitis in three dimensions. The tendons were assigned to volar, dorsal, ulnar and radial groups in the wrist and to extensor, flexor and thumb groups in the hand. Degree of tenosynovitis (graded 0-3), cross-sectional area and volume of the inflamed synovium in various tendon groups were then compared by statistical analysis. Review of the medical records revealed the following diagnoses in our patient population: rheumatoid arthritis (n=16), unspecified inflammatory polyarthritis (n=9), psoriatic arthritis (n=2), CREST syndrome (n=1), systemic lupus erythematosus (n=1), paraneoplastic syndrome with arthritis (n=1). The average T2 brightness scores and post-gadolinium enhancement scores were 1.0 and 1.7 respectively (P<0.001) in the wrist studies. The average T2 brightness scores and post-gadolinium enhancement scores were 0.7 and 1.4, respectively (P<0.001) in the hand studies. The average sensitivity of T2-weighted imaging for detection of tenosynovitis was 40% in the hand and 67% in the wrist tendons, when contrast-enhanced images were used as a reference. Carpal tunnel flexor tendons were the most frequently affected tendons of the wrist. The most frequently affected tendons of the hand were second and third flexor tendons. The hand flexors demonstrated higher degrees of enhancement and larger volumes of the inflamed tenosynovium than did the hand extensors and tendons of the thumb.

  6. Enhanced MR imaging of tenosynovitis of hand and wrist in inflammatory arthritis

    International Nuclear Information System (INIS)

    Tehranzadeh, J.; Ashilyan, O.; Anavim, A.; Tramma, S.

    2006-01-01

    The purpose of this study is to describe the appearance of tenosynovitis in various tendon groups in the wrist and hand and to compare MR enhanced and non-enhanced imaging evaluation of tenosynovitis of hand and wrist in inflammatory arthritis. We reviewed 72 MRI studies of hands and wrists, including coronal, axial and sagittal images in 30 consecutive patients with inflammatory arthritis and tenosynovitis. We compared the degree of synovitis on T2-weighted vs contrast-enhanced T1-weighted images, using a predetermined scale. We also measured the extent of tenosynovitis in three dimensions. The tendons were assigned to volar, dorsal, ulnar and radial groups in the wrist and to extensor, flexor and thumb groups in the hand. Degree of tenosynovitis (graded 0-3), cross-sectional area and volume of the inflamed synovium in various tendon groups were then compared by statistical analysis. Review of the medical records revealed the following diagnoses in our patient population: rheumatoid arthritis (n=16), unspecified inflammatory polyarthritis (n=9), psoriatic arthritis (n=2), CREST syndrome (n=1), systemic lupus erythematosus (n=1), paraneoplastic syndrome with arthritis (n=1). The average T2 brightness scores and post-gadolinium enhancement scores were 1.0 and 1.7 respectively (P<0.001) in the wrist studies. The average T2 brightness scores and post-gadolinium enhancement scores were 0.7 and 1.4, respectively (P<0.001) in the hand studies. The average sensitivity of T2-weighted imaging for detection of tenosynovitis was 40% in the hand and 67% in the wrist tendons, when contrast-enhanced images were used as a reference. Carpal tunnel flexor tendons were the most frequently affected tendons of the wrist. The most frequently affected tendons of the hand were second and third flexor tendons. The hand flexors demonstrated higher degrees of enhancement and larger volumes of the inflamed tenosynovium than did the hand extensors and tendons of the thumb

  7. Flexor digitorum profundus tendon anatomy in the forearm

    Directory of Open Access Journals (Sweden)

    Teoman Dogan

    2012-04-01

    Methods: We used 11 forearms belonging to cadavers and fixed with formaldehyde. The forearms numbered 1, 2, 8, 9, 10, 11 were the left and right arms of the same cadavers. Those numbered 3, 4, 5, 6, 7 belonged to different cadavers. Dissections were made by using the atraumatic surgical technique. The tendons were studied to identify the structure and number of the fibers forming them. Results: The presence of a large common tendon was found in 10 of the 11 forearms. In 4 of these, the common tendon included the tendons of all four fingers. While the common tendon included 3 fingers in four forearms, it only included tendons belonging to 2 fingers in two forearms. It was not possible in one forearm to separate the common tendon into its fibers. In another forearm, tendons belonging to each digit were separate and independent starting at the muscle-tendon junction to the attachment points. Conclusion: The majority of the cadaver forearms used in the study displayed a single large FDP tendon in the zone between the muscle-tendon joint to the carpal tunnel entry prior to being distributed into each index. This anatomical feature should be considered in choosing materials and surgical technique for Zone V FDP tendon injuries, as well as in planning the rehabilitation process. [Hand Microsurg 2012; 1(1.000: 25-29

  8. Mobilidade articular dos dedos não lesados pós-reparo em lesão dos tendões flexores da mão Joint range of motion of uninjured fingers after repairs to flexor tendon injuries of the hand

    Directory of Open Access Journals (Sweden)

    RB Rabelo

    2007-10-01

    Full Text Available OBJETIVO: Verificar a amplitude de movimento (ADM em mãos que sofreram reparo tendinoso dos músculos flexores superficial e profundo dos dedos, comparando os dados de cada dedo na mão lesada e entre mãos lesadas e não lesadas. MÉTODOS: Foi realizada a goniometria ativa em 15 pacientes e 120 dedos, 60 dedos de mãos lesadas e 60 de mãos controle não lesadas. Os sujeitos foram avaliados no momento da retirada da tala gessada, tendo sido realizada a movimentação precoce pelo método de Duran modificado. A partir dos dados goniométricos, foram registrados os valores do índice TAM (Total Active Motion dos dedos nas mãos lesadas e controle. Para análise dos dados, foi acessada a fórmula de índices funcionais proposta pela American Society for Surgery of the Hand (ASSH e para cálculo estatístico, foi escolhido o Modelo de Efeitos Mistos. RESULTADOS: A fórmula da ASSH para os dedos lesados mostrou que 18,33% tiveram a classificação do movimento "bom", 18,33%, "regular" e 63,34%, "pobre". Foram comparadas as médias das medidas em graus de todos os dedos entre si dentro de cada grupo, controle ou lesado, e as médias das medidas entre os grupos, encontrando-se um p-valor significante apenas entre os grupos controle e lesado. Não houve diferença estatística entre o TAM de cada dedo na mão lesada. CONCLUSÃO: Independente de quantos dedos tenham sofrido lesão tendinosa em uma mão, os dedos não lesados também terão suas ADMs ativas diminuídas no período logo após a retirada da imobilização.OBJECTIVE: To assess the range of motion (ROM in hands that underwent tendon repair in the flexor digitorum superficialis and flexor digitorum profundus muscles of the fingers, comparing the data between the fingers on the injured hand, and between the injured and uninjured hands. METHOD: Active goniometry was performed on 15 patients, making a total of 120 fingers (60 on injured hands and 60 on noninjured control hands. The patients

  9. Exercise-related alterations in crimp morphology in the central regions of superficial digital flexor tendons from young thoroughbreds: a controlled study.

    Science.gov (United States)

    Patterson-Kane, J C; Wilson, A M; Firth, E C; Parry, D A; Goodship, A E

    1998-01-01

    Injury to the core of the mid-metacarpal region of the superficial digital flexor tendon in Thoroughbred racehorses is a very frequent but poorly understood condition. It has been suggested that subclinical changes induced by galloping exercise weaken the collagen in this region of the tendon, predisposing it to rupture. The longitudinally arranged collagen fibrils in tendon follow a planar waveform, termed the crimp. Fibril bundles with a smaller crimp angle fail at a lower level of strain than those with a larger crimp angle. This study tested the hypothesis that a specific 18 month exercise programme would result in significant reduction of collagen fibril crimp angle and period length in the core region of the superficial digital flexor tendon of young Thoroughbreds (21 +/- 1 months), compared to the normal change in these parameters with age. Central region crimp angle and length were significantly lower in exercised horses than in control horses (P < 0.05). The crimp angle was significantly lower in this central region than in the peripheral region of the tendon in 4 of the 5 exercised horses, as was the crimp length in 3 of the 4 horses. The crimp angle in the peripheral region was significantly greater in exercised horses than in the controls (P < 0.05), which may indicate functional adaptation due to differing mechanical environment between the 2 tendon regions. The results of this study supported previous evidence that galloping exercise modifies normal age-related changes in crimp morphology in the core of the superficial digital flexor tendon. Such changes are indicative of microtrauma and would be detrimental to tendon strength.

  10. Silicone infusion tubing instead of Hunter rods for two-stage zone 2 flexor tendon reconstruction in a resource-limited surgical environment.

    Science.gov (United States)

    Kibadi, K; Moutet, F

    2017-10-01

    The authors describe their experience using silicone infusion tubing in place of Hunter rods for two-stage zone 2 flexor tendon reconstruction in a resource-limited surgical environment. This case report features a 47-year-old, right-handed man who had no active PIP and DIP joint flexion in four fingers of the right hand 5 months after an injury. During the first repair stage, the A2 and A4 pulleys were reconstructed using an extensor retinaculum graft. An infusion tube was inserted instead of Hunter rods. During the second stage, formation of a digital neo-canal around the infusion tubing was observed. The infusion tubing was removed and replaced with a palmaris longus tendon graft according to the conventional technique. Physiotherapy and rehabilitation followed surgery. At 6 months, very significant progress had been made with complete recovery of PIP and DIP flexion in the four fingers. Copyright © 2017 SFCM. Published by Elsevier Masson SAS. All rights reserved.

  11. Validation of color Doppler sonography for evaluating relative displacement between the flexor tendon and subsynovial connective tissue.

    Science.gov (United States)

    Tat, Jimmy; Kociolek, Aaron M; Keir, Peter J

    2015-04-01

    A common pathologic finding in carpal tunnel syndrome is fibrosis and thickening of the subsynovial connective tissue. This finding suggests an etiology of excessive shear forces, with relative longitudinal displacement between the flexor tendon and adjacent subsynovial connective tissue. The purpose of this study was to validate color Doppler sonography for measurement of tendon displacement over time. Eight unmatched fresh frozen cadaver arms were used to evaluate color Doppler sonography for measurement of tendon displacement. The middle flexor digitorum superficialis tendon was moved through a physiologic excursion of 20 mm at 3 different tendon velocities (50, 100, and 150 mm/s). We found that color Doppler sonography provided accurate measurement of tendon displacement, with absolute errors of -0.05 mm (50 mm/s), -1.24 mm (100 mm/s), and -2.36 mm (150 mm/s) on average throughout the tendon excursion range. Evaluating relative displacement between the tendon and subsynovial connective tissue during finger flexion-extension movements also offered insight into the gliding mechanism of the subsynovial connective tissue. During flexion, we observed a curvilinear increase in relative displacement, with greater differential motion at the end range of displacement, likely due to the sequential stretch of the fibrils between successive layers of the subsynovial connective tissue. In extension, there was a linear return in relative displacement, suggesting a different unloading mechanism characterized by uniform relaxation of fibrils. We demonstrated the validity of color Doppler displacement for use in the evaluation of relative motion. Color Doppler sonography is useful in our understanding of the behavior of the subsynovial connective tissue during tendon excursion, which may elucidate the role of finger motion in the etiology of shear injury. © 2015 by the American Institute of Ultrasound in Medicine.

  12. Intraoperative extracorporeal autogenous irradiated tendon grafts for functional limb salvage surgery of soft tissue sarcomas of the wrist and hand.

    Science.gov (United States)

    Omori, Shinsuke; Hamada, Kenichiro; Outani, Hidetatsu; Oshima, Kazuya; Joyama, Susumu; Tomita, Yasuhiko; Naka, Norifumi; Araki, Nobuhito; Yoshikawa, Hideki

    2015-05-12

    In patients with soft tissue sarcoma of the wrist and hand, limb salvage operation is extremely challenging for surgeons in attempting a complete tumor resection with negative surgical margins. In this study, we report four patients with soft tissue sarcoma of the wrist and hand treated by limb salvage operation with intraoperative extracorporeal autogenous irradiated tendon grafts. The patients were all male, and the mean age at the time of surgery was 45 years. Histological diagnoses included clear cell sarcoma in two patients, synovial sarcoma in one, and angiosarcoma in one. All four patients had high grade tumors, wherein three had American Joint Committee on Cancer (AJCC) stage III disease and one with AJCC stage IV disease. The tumors were resected en bloc with involved tendons. The tendons were isolated from the resected tissues, irradiated ex vivo, and re-implanted into the host tendons. In one patient, the bone was resected additionally because of tumor invasion to the bone. Hand function was evaluated using Musculoskeletal Tumor Society (MSTS) rating system. Of the four patients, three died of distant metastatic disease. The remaining patient lives and remains disease-free. The mean follow-up period was 33 months. One patient had local recurrence outside the irradiated graft at 20 months after surgery. The functional rating was 22. Lower scores were seen in patients with reconstruction of flexor tendons than extensor tendons. Limb salvage operation with intraoperative extracorporeal autogenous irradiated tendon grafts is an acceptable method in selected patients with soft tissue sarcoma of the wrist and hand.

  13. Bundles of spider silk, braided into sutures, resist basic cyclic tests: potential use for flexor tendon repair.

    Directory of Open Access Journals (Sweden)

    Kathleen Hennecke

    Full Text Available Repair success for injuries to the flexor tendon in the hand is often limited by the in vivo behaviour of the suture used for repair. Common problems associated with the choice of suture material include increased risk of infection, foreign body reactions, and inappropriate mechanical responses, particularly decreases in mechanical properties over time. Improved suture materials are therefore needed. As high-performance materials with excellent tensile strength, spider silk fibres are an extremely promising candidate for use in surgical sutures. However, the mechanical behaviour of sutures comprised of individual silk fibres braided together has not been thoroughly investigated. In the present study, we characterise the maximum tensile strength, stress, strain, elastic modulus, and fatigue response of silk sutures produced using different braiding methods to investigate the influence of braiding on the tensile properties of the sutures. The mechanical properties of conventional surgical sutures are also characterised to assess whether silk offers any advantages over conventional suture materials. The results demonstrate that braiding single spider silk fibres together produces strong sutures with excellent fatigue behaviour; the braided silk sutures exhibited tensile strengths comparable to those of conventional sutures and no loss of strength over 1000 fatigue cycles. In addition, the braiding technique had a significant influence on the tensile properties of the braided silk sutures. These results suggest that braided spider silk could be suitable for use as sutures in flexor tendon repair, providing similar tensile behaviour and improved fatigue properties compared with conventional suture materials.

  14. A barbed suture repair for flexor tendons: a novel technique with no exposed barbs.

    Science.gov (United States)

    Joyce, Cormac W; Sugrue, Conor; Chan, Jeffrey C; Delgado, Luis; Zeugolis, Dimitrios; Carroll, Seam M; Kelly, Jack L

    2014-10-01

    Barbed suture technology has shown promise in flexor tendon repairs, as there is an even distribution of load and the need for a knot is eliminated. We propose that a quick and simple, novel, barbed technique without any exposed barbs on the tendon surface has comparable strength and a smaller cross-sectional area at the repair site than traditional methods of repair. Forty porcine flexor tendons were randomized to polybutester 4-strand barbed repair or to 4-strand Adelaide monofilament repair. The cross-sectional area was measured before and after repair. Biomechanical testing was carried out and 2-mm gap formation force, ultimate strength of repair, and method of failure were recorded. The mean ultimate strength of the barbed repairs was 54.51 ± 17.9 while that of the Adelaide repairs was 53.17 ± 16.35. The mean 2-mm gap formation force for the barbed group was 44.71 ± 17.86 whereas that of the Adelaide group was 20.25 ± 4.99. The postrepair percentage change in cross-sectional area at the repair site for the Adelaide group and barbed group was 12.0 ± 2.3 and 4.6 ± 2.8, respectively. We demonstrated that a 4-strand knotless, barbed method attained comparable strength to that of the traditional Adelaide repair technique. The barbed method had a significantly reduced cross-sectional area at the repair site compared with the Adelaide group. The 2-mm gap formation force was less in the barbed group than the Adelaide group. Barbed repairs show promise for tendon repairs; this simple method warrants further study in an animal model.

  15. A Biomechanical Simulation of the Effect of the Extrinsic Flexor Muscles on Finger Joint Flexion

    Science.gov (United States)

    2001-10-25

    vol. 44, pp. 493-504, 1997. [8] A.B. Leger and T.E. Milner, “The effect of eccentric exercise on intrinsic and reflex stiffness in the human hand...line of action of the tendons and the effective moment arms. After a certain point, the FDP tendon became slack, while the FDS tendon remained...link chain with three revolute joints and four links was created to model the index finger. The tendons from the extrinsic flexor muscles were

  16. The influence of exercise during growth on ultrasonographic parameters of the superficial digital flexor tendon of young Thoroughbred horses.

    Science.gov (United States)

    Moffat, P A; Firth, E C; Rogers, C W; Smith, R K W; Barneveld, A; Goodship, A E; Kawcak, C E; McIlwraith, C W; van Weeren, P R

    2008-03-01

    Conditioning by early training may influence the composition of certain musculoskeletal tissues, but very few data exist on its effect during growth on tendon structure and function. To investigate whether conditioning exercise in young foals would lead to any ultrasonographically detectable damage to the superficial digital flexor tendon or an increase in cross-sectional area (CSA). Thirty-three Thoroughbred foals reared at pasture were allocated to 2 groups: control (PASTEX) allowed exercise freely at pasture; and CONDEX, also at pasture, began conditioning exercise from mean age 21 days over 1030 m on a purpose-built oval grass track, for 5 days/week until mean age 18 months. Foals were observed daily, and underwent orthopaedic examination monthly. Ultrasonographic images of the superficial digital flexor tendon (SDFT) at the mid-metacarpal level of both forelimbs were obtained in all foals at ages 5, 8, 12, 15 and 18 months. CSA was validated (r(2) = 0.89) by determining CSA from digital photographs of the transected SDFT surface from 12 of the horses necropsied at age 17.1 months. here was no clinical or ultrasonographic evidence of tendonopathy in either group and the greatest increase in mean CSA in both groups occurred between age 5 and 8 months. Across all age categories, there was no significant difference in mean CSA between the left and right limbs, or colts and fillies; there was a trend towards a larger CSA in the CONDEX group (P = 0.058). There was no conclusive evidence for a structural adaptive hypertrophy of the SDFT, probably because the regimen was insufficiently rigorous or because spontaneous pasture exercise may induce maximal development of energy storing tendons. A moderate amount of early conditioning exercise against a background of constant exercise at pasture is not harmful to the development of the flexor tendons.

  17. Tendon 'turnover lengthening' technique.

    Science.gov (United States)

    Cerovac, S; Miranda, B H

    2013-11-01

    Tendon defect reconstruction is amongst the most technically challenging areas in hand surgery. Tendon substance deficiency reconstruction techniques include lengthening, grafting, two-stage reconstruction and tendon transfers, however each is associated with unique challenges over and above direct repair. We describe a novel 'turnover lengthening' technique for hand tendons that has successfully been applied to the repair of several cases, including a case of attritional flexor and traumatic extensor tendon rupture in two presented patients where primary tenorrhaphy was not possible. In both cases a good post-operative outcome was achieved, as the patients were happy having returned back to normal activities of daily living such that they were discharged 12 weeks post-operatively. Our technique avoids the additional morbidity and complications associated with grafting, transfers and two stage reconstructions. It is quick, simple and reproducible for defects not exceeding 3-4 cm, provides a means of immediate one stage reconstruction, no secondary donor site morbidity and does not compromise salvage by tendon transfer and/or two-stage reconstruction in cases of failure. To our knowledge no such technique has been previously been described to reconstruct such hand tendon defects. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  18. Congenital dislocation of the deep digital flexor tendon associated with hypoplasia of the sustentaculum tali in a Thoroughbred colt

    International Nuclear Information System (INIS)

    Lepage, O.M.; Leveille, R.; Breton, L.; Marcoux, M.

    1995-01-01

    An 11-month-old Thoroughbred colt was presented with a hard swelling at the proximal third of the right 4th metatarsal bone. A medial dislocation of the deep digital flexor tendon (flexor digitorum profundus) was also observed on the same leg. On the plantaroproximal-plantarodistal projection of the calcaneus, there was flattening and shortening of the sustentaculum tali. The smooth bony proliferation at the proximal third of the right 4th metatarus was compatible with a chronic splint bone fracture. This report describes a medial deep digital flexor dislocation associated with hypoplasia of the sustentaculum tali

  19. Flexor pollicis longus repair in a patient with Linburg-Comstock anomaly: A case report

    Directory of Open Access Journals (Sweden)

    Mehmet Unal

    2016-08-01

    Results: At the end of the rehabilitation program, the thumb recovered full range of motion, and physical examination revealed synchronous flexion movement (synkinesis of the thumb and index finger. Conclusion: Flexor pollicis longus tendon lacerations are common in the clinical practice of hand surgeons. Making a separate proximal wrist incision is a very useful technique to reach a proximal tendon stump. Otherwise, aggressive maneuvers may cause additional damage to the tendons involved and result in unpredicted outcomes. The attempts to retrieve the tendon at the injury site resulted in failure and gave a tethering sensation to the surgeon who recalled the Linburg-Comstock anomaly. [Hand Microsurg 2016; 5(2.000: 88-91

  20. Stress examination of flexor tendon pulley rupture in the crimp grip position: a 1.5-Tesla MRI cadaver study

    Energy Technology Data Exchange (ETDEWEB)

    Bayer, Thomas; Janka, Rolf [University of Erlangen-Nuremberg, Department of Radiology, Erlangen (Germany); Fries, Simon [Cantonal Hospital Lucerne, Orthopaedic Department, Wolhusen (Switzerland); Schweizer, Andreas [University of Zurich, Department of Orthopaedics, Balgrist, Zurich (Switzerland); Schoeffl, Isabelle [Klinikum Bamberg, Department of Pediatrics, Bamberg (Germany); Bongartz, Georg [University Basel, Department of Radiology, Basel (Switzerland)

    2015-01-15

    The objectives of this study were the evaluation of flexor tendon pulley rupture of the fingers in the crimp grip position using magnetic resonance imaging (MRI) and the comparison of the results with MRI in the neutral position in a cadaver study. MRI in the crimp grip position and in the neutral position was performed in 21 cadaver fingers with artificially created flexor tendon pulley tears (combined pulley rupture, n = 14; single pulley rupture, n = 7). Measurement of the distance between the tendon and bone was performed. Images were evaluated by two readers, first independently and in cases of discrepancy in consensus. Sensitivity and specificity for detecting combined pulley ruptures were calculated. Tendon bone distances were significantly higher in the crimp grip position than in the neutral position. Sensitivity and specificity for detecting combined pulley rupture were 92.86 % and 100 % respectively in the crimp grip position and 78.57 % and 85.71 % respectively in the neutral position. Kappa values for interobserver reliability were 0.87 in the crimp grip position and 0.59 in the neutral position. MRI examination in the crimp grip position results in higher tendon bone distances by subjecting the pulleys to a higher strain, which facilitates image evaluation with higher interobserver reliability, higher sensitivity, and higher specificity for combined pulley rupture compared with examination in the neutral position. (orig.)

  1. Flexor hallucis longus tendon rupture in RA-patients is associated with MTP 1 damage and pes planus

    NARCIS (Netherlands)

    Baan, H.; Baan, Henriette; Drossaers-Bakker, K.W.; Dubbeldam, Rosemary; Dubbeldam, Rosemary; Buurke, Jaap J.; Nene, A.V.; van de Laar, Mart A F J

    2007-01-01

    Background: To assess the prevalence of and relation between rupture or tenosynovitis of the Flexor Hallucis Longus (FHL) tendon and range of motion, deformities and joint damage of the forefoot in RA patients with foot complaints. Methods: Thirty RA patients with painful feet were analysed, their

  2. Determining flexor-tendon repair techniques via soft computing

    Science.gov (United States)

    Johnson, M.; Firoozbakhsh, K.; Moniem, M.; Jamshidi, M.

    2001-01-01

    An SC-based multi-objective decision-making method for determining the optimal flexor-tendon repair technique from experimental and clinical survey data, and with variable circumstances, was presented. Results were compared with those from the Taguchi method. Using the Taguchi method results in the need to perform ad-hoc decisions when the outcomes for individual objectives are contradictory to a particular preference or circumstance, whereas the SC-based multi-objective technique provides a rigorous straightforward computational process in which changing preferences and importance of differing objectives are easily accommodated. Also, adding more objectives is straightforward and easily accomplished. The use of fuzzy-set representations of information categories provides insight into their performance throughout the range of their universe of discourse. The ability of the technique to provide a "best" medical decision given a particular physician, hospital, patient, situation, and other criteria was also demonstrated.

  3. BIOMECHANICS AND HISTOLOGICAL ANALYSIS IN RABBIT FLEXOR TENDONS REPAIRED USING THREE SUTURE TECHNIQUES (FOUR AND SIX STRANDS) WITH EARLY ACTIVE MOBILIZATION.

    Science.gov (United States)

    Severo, Antônio Lourenço; Arenhart, Rodrigo; Silveira, Daniela; Ávila, Aluísio Otávio Vargas; Berral, Francisco José; Lemos, Marcelo Barreto; Piluski, Paulo César Faiad; Lech, Osvandré Luís Canfield; Fukushima, Walter Yoshinori

    2012-01-01

    Analyzing suture time, biomechanics (deformity between the stumps) and the histology of three groups of tendinous surgical repair: Brazil-2 (4-strands) which the end knot (core) is located outside the tendon, Indiana (4-strands) and Tsai (6-strands) with sutures technique which the end knot (core) is inner of the tendon, associated with early active mobilization. The right calcaneal tendons (plantar flexor of the hind paw) of 36 rabbits of the New Zealand breed (Oryctolagus cuniculus) were used in the analysis. This sample presents similar size to human flexor tendon that has approximately 4.5 mm (varying from 2mm). The selected sample showed the same mass (2.5 to 3kg) and were male or female adults (from 8 ½ months). For the flexor tendons of the hind paws, sterile and driven techniques were used in accordance to the Committee on Animal Research and Ethics (CETEA) of the University of the State of Santa Catarina (UDESC), municipality of Lages, in Brazil (protocol # 1.33.09). In the biomechanical analysis (deformity) carried out between tendinous stumps, there was no statistically significant difference (p>0.01). There was no statistical difference in relation to surgical time in all three suture techniques with a mean of 6.0 minutes for Tsai (6- strands), 5.7 minutes for Indiana (4-strands) and 5.6 minutes for Brazil (4-strands) (p>0.01). With the early active mobility, there was qualitative and quantitative evidence of thickening of collagen in 38.9% on the 15(th) day and in 66.7% on the 30(th) day, making the biological tissue stronger and more resistant (p=0.095). This study demonstrated that there was no histological difference between the results achieved with an inside or outside end knot with respect to the repaired tendon and the number of strands did not affect healing, vascularization or sliding of the tendon in the osteofibrous tunnel, which are associated with early active mobility, with the repair techniques applied.

  4. BIOMECHANICS AND HISTOLOGICAL ANALYSIS IN RABBIT FLEXOR TENDONS REPAIRED USING THREE SUTURE TECHNIQUES (FOUR AND SIX STRANDS) WITH EARLY ACTIVE MOBILIZATION

    Science.gov (United States)

    Severo, Antônio Lourenço; Arenhart, Rodrigo; Silveira, Daniela; Ávila, Aluísio Otávio Vargas; Berral, Francisco José; Lemos, Marcelo Barreto; Piluski, Paulo César Faiad; Lech, Osvandré Luís Canfield; Fukushima, Walter Yoshinori

    2015-01-01

    Objective: Analyzing suture time, biomechanics (deformity between the stumps) and the histology of three groups of tendinous surgical repair: Brazil-2 (4-strands) which the end knot (core) is located outside the tendon, Indiana (4-strands) and Tsai (6-strands) with sutures technique which the end knot (core) is inner of the tendon, associated with early active mobilization. Methods: The right calcaneal tendons (plantar flexor of the hind paw) of 36 rabbits of the New Zealand breed (Oryctolagus cuniculus) were used in the analysis. This sample presents similar size to human flexor tendon that has approximately 4.5 mm (varying from 2mm). The selected sample showed the same mass (2.5 to 3kg) and were male or female adults (from 8 ½ months). For the flexor tendons of the hind paws, sterile and driven techniques were used in accordance to the Committee on Animal Research and Ethics (CETEA) of the University of the State of Santa Catarina (UDESC), municipality of Lages, in Brazil (protocol # 1.33.09). Results: In the biomechanical analysis (deformity) carried out between tendinous stumps, there was no statistically significant difference (p>0.01). There was no statistical difference in relation to surgical time in all three suture techniques with a mean of 6.0 minutes for Tsai (6- strands), 5.7 minutes for Indiana (4-strands) and 5.6 minutes for Brazil (4-strands) (p>0.01). With the early active mobility, there was qualitative and quantitative evidence of thickening of collagen in 38.9% on the 15th day and in 66.7% on the 30th day, making the biological tissue stronger and more resistant (p=0.095). Conclusion: This study demonstrated that there was no histological difference between the results achieved with an inside or outside end knot with respect to the repaired tendon and the number of strands did not affect healing, vascularization or sliding of the tendon in the osteofibrous tunnel, which are associated with early active mobility, with the repair techniques

  5. From collagen to tenocyte : How the equine superficial digital flexor tendon responds to physiologic challenges and physical therapy

    NARCIS (Netherlands)

    Lin, Yi-Lo

    2005-01-01

    Introduction Injuries to the equine superficial digital flexor tendon (SDFT) play a prominent role in the orthopaedic disorders and form an important threat to both the equine athletic potential and welfare. Therefore this thesis aims at in-depth understanding the development of ECM composition in

  6. One-stage treatment of delayed 'jersey finger' by Z-step lengthening of the flexor digitorum profundus tendon at the wrist.

    Science.gov (United States)

    Sawaya, Elias T; Choughri, Hussein; Pelissier, Philippe

    2012-02-01

    The authors report the case of a 19-year-old female with delayed presentation of a type II 'jersey finger' of the fourth dominant digit. A surgical approach was performed, revealing a retracted flexor digitorum profundus tendon within a still patent sheath. The resulting loss of tendon length overruled any possibility of direct reinsertion of the tendon. A lengthening "Z-step" tendinoplasty was then performed on the tendon at the wrist, thus enabling reinsertion at the base of the distal phalanx. The patient then underwent conventional splinting and physiotherapy. Total Active Motion was measured at 220° with a 6-month follow-up. Even though there is no clear consensus concerning management of such cases, different techniques have been described, such as one- or two-stage grafting, or tenotomy at the musculotendinous junction. Lengthening tendinoplasties have been applied by certain authors but only to the flexor pollicis longus tendon. To our knowledge, this is the only reported case of lengthening Z-step applied to a long digit for the repair of type II 'jersey finger' lesions. The satisfactory functional and cosmetic outcome encourages us to consider this one-stage technique in other select cases, in order to gather more formal evidence. Copyright © 2011 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  7. Flexor zone 5 cut injuries: emergency management and outcome

    International Nuclear Information System (INIS)

    Raza, M.S.

    2014-01-01

    To determine the outcome and devise a protocol for emergency management of cut injuries in Flexor Zone 5 of hands. Study Design: Descriptive study. Place and Duration of Study: Department of Plastic Surgery and Burn Unit, Mayo Hospital, KEMU, Lahore, Pakistan, from January 2009 to March 2013. Methodology: All patients above 12 years of age with single sharp cut injuries in Flexor Zone 5, with no skeletal injuries, presenting within 12 hours in emergency were included with follow-up of 6 months, with active range of motion evaluated by Strickland's adjusted formula. Power of opponens pollicis and adductor muscles was evaluated from P0-4. Nerve repair results were evaluated serially by advancing Tinnel's sign, electrophysiological studies and sensory perception scored from S0-4 compared to the normal opposite upper limb. Results: The study group comprised of 31 patients (M : F = 2.4 : 1). Average age was 27 years ranging from 17 - 53 years. In 25 (80%) cases, injury was accidental, in 3 (10%) homicidal and in 3 (10%) injury was suicidal. Four most commonly involved structures included Flexor carpi ulnaris, ulnar artery, ulnar nerve and Flexor digitorum superficialis. Median nerve and radial artery were involved in 10 cases each, while ulnar artery and ulnar nerve were involved in 14 cases each. Longtendons were involved in most cases with greater involvement of medial tendons. None of the patients required re-exploration for ischaemia of distal limb while doppler showed 22 out of 24 vascular anastomosis remained patent. Recovery of long-tendons was good and recovery after nerve repair was comparable in both median and ulnar nerves. Conclusion: Early and technically proper evaluation, exploration and repair of Zone 5 Flexor tendon injuries results in good functional and technical outcome. (author)

  8. Influence of the position of the foot on MRI signal in the deep digital flexor tendon and collateral ligaments of the distal interphalangeal joint in the standing horse.

    Science.gov (United States)

    Spriet, M; Zwingenberger, A

    2009-05-01

    Hyperintense signal is sometimes observed in ligaments and tendons of the equine foot on standing magnetic resonance examination without associated changes in size and shape. In such cases, the presence of a true lesion or an artifact should be considered. A change in position of a ligament or tendon relative to the magnetic field can induce increased signal intensity due to the magic angle effect. To assess if positional rotation of the foot in the solar plane could be responsible for artifactual changes in signal intensity in the collateral ligaments of the distal interphalangeal joint and in the deep digital flexor tendon. Six isolated equine feet were imaged with a standing equine magnetic resonance system in 9 different positions with different degrees of rotation in the solar plane. Rotation of the limb induced a linear hyperintense signal on all feet at the palmar aspect of one of the lobes of the deep digital flexor tendon and at the dorsal aspect of the other lobe. Changes in signal intensity in the collateral ligaments of the distal interphalangeal joint occurred with rotation of the limb only in those feet where mediolateral hoof imbalance was present. The position and conformation of the foot influence the signal intensity in the deep digital flexor tendon and in the collateral ligaments of the distal interphalangeal joint. The significance of increased signal intensity in the deep digital flexor tendon and in the collateral ligaments of the distal interphalangeal joint should be interpreted with regard to the position and the conformation of the foot.

  9. A repeated carpal tunnel syndrome due to tophaceous gout in flexor tendon

    Science.gov (United States)

    Lu, Hui; Chen, Qiang; Shen, Hui

    2017-01-01

    Abstract Rationale: Gouty tophi is a rare cause of CTS. We first report a unique case of repeated CTS with gouty tophi in flexor tendon. In the previous literature, the symptoms cases of CTS were gradually increased. Patient concerns: We report a 44-year-old male porter presented with mass on his left distal forearm combined a repeated carpal tunnel syndrome for 5 years. He felt numbness in fingers and his left palmar. The CTS symptoms had been eased through rest and dugs medication. It recurred twice. Diagnoses: Monosodium urate crystal deposits were found in surgery. Histologic findings confirmed the diagnosis of gout. Interventions: We removed partial of gouty tophus and retained the integrity of the tendon. Outcomes: Two years after the surgery, the patient had not experienced any symptom recurrence. Lessons: Early diagnosis and control of gout are necessary to avoid irreversible complications. The surgery combined with decreasing trioxypurine treatment can improve the treatment outcome of gouty tophus. PMID:28248892

  10. Composition and structure of porcine digital flexor tendon-bone insertion tissues.

    Science.gov (United States)

    Chandrasekaran, Sandhya; Pankow, Mark; Peters, Kara; Huang, Hsiao-Ying Shadow

    2017-11-01

    Tendon-bone insertion is a functionally graded tissue, transitioning from 200 MPa tensile modulus at the tendon end to 20 GPa tensile modulus at the bone, across just a few hundred micrometers. In this study, we examine the porcine digital flexor tendon insertion tissue to provide a quantitative description of its collagen orientation and mineral concentration by using Fast Fourier Transform (FFT) based image analysis and mass spectrometry, respectively. Histological results revealed uniformity in global collagen orientation at all depths, indicative of mechanical anisotropy, although at mid-depth, the highest fiber density, least amount of dispersion, and least cellular circularity were evident. Collagen orientation distribution obtained through 2D FFT of histological imaging data from fluorescent microscopy agreed with past measurements based on polarized light microscopy. Results revealed global fiber orientation across the tendon-bone insertion to be preserved along direction of physiologic tension. Gradation in the fiber distribution orientation index across the insertion was reflective of a decrease in anisotropy from the tendon to the bone. We provided elemental maps across the fibrocartilage for its organic and inorganic constituents through time-of-flight secondary ion mass spectrometry (TOF-SIMS). The apatite intensity distribution from the tendon to bone was shown to follow a linear trend, supporting past results based on Raman microprobe analysis. The merit of this study lies in the image-based simplified approach to fiber distribution quantification and in the high spatial resolution of the compositional analysis. In conjunction with the mechanical properties of the insertion tissue, fiber, and mineral distribution results for the insertion from this may potentially be incorporated into the development of a structural constitutive approach toward computational modeling. Characterizing the properties of the native insertion tissue would provide the

  11. Hand assessment with the E-Cone in rheumatoid arthritis and hand osteoarthritis

    NARCIS (Netherlands)

    van Merendonk, N.; van Alebeek, V.; Spreeuwers, Lieuwe Jan; Spreeuwers, D.; Kroon, P.J.; Roorda, L.; Dekker, J.; Hoeksma, A.F.

    2013-01-01

    Background: Rheumatoid arthritis (RA) is a systemic inflammatory, progressive disease resulting in deformities of the hand. Besides synovitis, tenosynovitis of the extrinsic flexor tendons is one of the initial features of RA, leading to friction and consequently to an imbalanced coordination of the

  12. Nonoperative, dynamic treatment of acute achilles tendon rupture

    DEFF Research Database (Denmark)

    Barfod, Kristoffer Weisskirchner; Bencke, Jesper; Lauridsen, Hanne Bloch

    2015-01-01

    Acute Achilles tendon rupture alters the biomechanical properties of the plantar flexor muscle-tendon complex that can affect functional performance and the risk of repeat injury. The purpose of the present study was to compare the biomechanical properties of the plantar flexor muscle-tendon comp......Acute Achilles tendon rupture alters the biomechanical properties of the plantar flexor muscle-tendon complex that can affect functional performance and the risk of repeat injury. The purpose of the present study was to compare the biomechanical properties of the plantar flexor muscle...... in the terminal part of dorsiflexion was found in the non-weightbearing group. The altered stiffness and strength in the affected limb could affect the coordination of gait and running....

  13. Does strand configuration and number of purchase points affect the biomechanical behavior of a tendon repair? A biomechanical evaluation using different kessler methods of flexor tendon repair.

    Science.gov (United States)

    Dogramaci, Yunus; Kalaci, Aydiner; Sevinç, Teoman Toni; Esen, Erdinc; Komurcu, Mahmut; Yanat, Ahmet Nedim

    2008-09-01

    This study compares the mechanical properties of modified Kessler and double-modified Kessler flexor tendon repair techniques and evaluates simple modifications on both methods. Forty fresh sheep flexor tendons were divided equally into four groups. A transverse sharp cut was done in the middle of each tendon and then repaired with modified Kessler technique, modified Kessler with additional purchase point in the midpoint of each longitudinal strand, double-modified Kessler technique, or a combination of outer Kessler and inner cruciate configuration based on double-modified Kessler technique. The tendons were tested in a tensile testing machine to assess the mechanical performance of the repairs. Outcome measures included gap formation and ultimate forces. The gap strengths of the double-modified Kessler technique (30.85 N, SD 1.90) and double-modified Kessler technique with inner cruciate configuration (33.60 N, SD 4.64) were statistically significantly greater than that of the two-strand modified Kessler (22.56 N, SD 3.44) and modified Kessler with additional purchase configuration (21.75 N, SD 4.03; Tukey honestly significant difference test, P purchase point in modified Kessler repair or changing the inner strand configuration in double-modified Kessler repair. The results of this study show that the number of strands across the repair site together with the number of locking loops clearly affects the strength of the repair; meanwhile, the longitudinal strand orientation and number of purchase points in a single loop did not affect its strength.

  14. Chiasma crurale: intersection of the tibialis posterior and flexor digitorum longus tendons above the ankle. Magnetic resonance imaging-anatomic correlation in cadavers

    Energy Technology Data Exchange (ETDEWEB)

    Buck, Florian M. [VA San Diego Medical Center, Department of Radiology, San Diego, CA (United States); Institut fuer Diagnostische Radiologie, Zurich (Switzerland); Gheno, Ramon; Nico, Marcelo A.C.; Trudell, Debra J.; Resnick, Donald [VA San Diego Medical Center, Department of Radiology, San Diego, CA (United States); Haghighi, Parviz [VA San Diego Medical Center, Department of Pathology, San Diego, CA (United States)

    2010-06-15

    To determine the precise anatomy and magnetic resonance (MR) imaging appearance of the chiasma crurale in cadavers, paying special attention to degenerative changes Twelve fresh human ankles were harvested from 11 nonembalmed cadavers (mean age at death 77 years) and used according to institutional guidelines. MR imaging and MR tenography were used to investigate the anatomy of the chiasma crurale using proton density-weighted sequences. The gross anatomy of the chiasma crurale was evaluated and compared to the MR imaging findings. Histology was used to elucidate further the structure of the chiasma crurale. Above the chiasma, five specimens had a small amount of fat tissue between the tibialis posterior and flexor digitorum longus tendon. In all specimens both tendons had a sheath below the chiasma but not above it. At the central portion of the chiasma there was no soft tissue between the tendons, except in two specimens that showed an anatomic variant consisting of a thick septum connecting the tibial periosteum and the deep transverse fascia of the leg. In MR images, eight specimens showed what were believed to be degenerative changes in the tendons at the level of the chiasma. However, during gross inspection and histologic analysis of the specimens, there was no tendon degeneration visible. At the central portion of the chiasma, there is no tissue between the tibialis posterior and flexor digitorum longus tendons unless there is an anatomic variant. At the chiasma crurale, areas with irregular tendon surfaces are normal findings and are not associated with tendon degeneration (fraying). (orig.)

  15. Evaluating adhesion reduction efficacy of type I/III collagen membrane and collagen-GAG resorbable matrix in primary flexor tendon repair in a chicken model.

    Science.gov (United States)

    Turner, John B; Corazzini, Rubina L; Butler, Timothy J; Garlick, David S; Rinker, Brian D

    2015-09-01

    Reduction of peritendinous adhesions after injury and repair has been the subject of extensive prior investigation. The application of a circumferential barrier at the repair site may limit the quantity of peritendinous adhesions while preserving the tendon's innate ability to heal. The authors compare the effectiveness of a type I/III collagen membrane and a collagen-glycosaminoglycan (GAG) resorbable matrix in reducing tendon adhesions in an experimental chicken model of a "zone II" tendon laceration and repair. In Leghorn chickens, flexor tendons were sharply divided using a scalpel and underwent repair in a standard fashion (54 total repairs). The sites were treated with a type I/III collagen membrane, collagen-GAG resorbable matrix, or saline in a randomized fashion. After 3 weeks, qualitative and semiquantitative histological analysis was performed to evaluate the "extent of peritendinous adhesions" and "nature of tendon healing." The data was evaluated with chi-square analysis and unpaired Student's t test. For both collagen materials, there was a statistically significant improvement in the degree of both extent of peritendinous adhesions and nature of tendon healing relative to the control group. There was no significant difference seen between the two materials. There was one tendon rupture observed in each treatment group. Surgical handling characteristics were subjectively favored for type I/III collagen membrane over the collagen-GAG resorbable matrix. The ideal method of reducing clinically significant tendon adhesions after injury remains elusive. Both materials in this study demonstrate promise in reducing tendon adhesions after flexor tendon repair without impeding tendon healing in this model.

  16. Optimization of human tendon tissue engineering: peracetic acid oxidation for enhanced reseeding of acellularized intrasynovial tendon.

    Science.gov (United States)

    Woon, Colin Y L; Pridgen, Brian C; Kraus, Armin; Bari, Sina; Pham, Hung; Chang, James

    2011-03-01

    Tissue engineering of human flexor tendons combines tendon scaffolds with recipient cells to create complete cell-tendon constructs. Allogenic acellularized human flexor tendon has been shown to be a useful natural scaffold. However, there is difficulty repopulating acellularized tendon with recipient cells, as cell penetration is restricted by a tightly woven tendon matrix. The authors evaluated peracetic acid treatment in optimizing intratendinous cell penetration. Cadaveric human flexor tendons were harvested, acellularized, and divided into experimental groups. These groups were treated with peracetic acid in varying concentrations (2%, 5%, and 10%) and for varying time periods (4 and 20 hours) to determine the optimal treatment protocol. Experimental tendons were analyzed for differences in tendon microarchitecture. Additional specimens were reseeded by incubation in a fibroblast cell suspension at 1 × 10(6) cells/ml. This group was then analyzed for reseeding efficacy. A final group underwent biomechanical studies for strength. The optimal treatment protocol comprising peracetic acid at 5% concentration for 4 hours produced increased scaffold porosity, improving cell penetration and migration. Treated scaffolds did not show reduced collagen or glycosaminoglycan content compared with controls (p = 0.37 and p = 0.65, respectively). Treated scaffolds were cytotoxic to neither attached cells nor the surrounding cell suspension. Treated scaffolds also did not show inferior ultimate tensile stress or elastic modulus compared with controls (p = 0.26 and p = 0.28, respectively). Peracetic acid treatment of acellularized tendon scaffolds increases matrix porosity, leading to greater reseeding. It may prove to be an important step in tissue engineering of human flexor tendon using natural scaffolds.

  17. Essential hand surgery procedures for mastery by graduating plastic surgery residents: a survey of program directors.

    Science.gov (United States)

    Noland, Shelley S; Fischer, Lauren H; Lee, Gordon K; Friedrich, Jeffrey B; Hentz, Vincent R

    2013-12-01

    This study was designed to establish the essential hand surgery procedures that should be mastered by graduating plastic surgery residents. This framework can then be used as a guideline for developing Objective Structured Assessment of Technical Skill to teach technical skills in hand surgery. Ten expert hand surgeons were surveyed regarding the essential hand surgery procedures that should be mastered by graduating plastic surgery residents. The top 10 procedures from this survey were then used to survey all 89 Accreditation Council for Graduate Medical Education-approved plastic surgery program directors. There was a 69 percent response rate to the program director survey (n = 61). The top nine hand surgery procedures included open carpal tunnel release, open A1 pulley release, digital nerve repair with microscope, closed reduction and percutaneous pinning of metacarpal fracture, excision of dorsal or volar ganglion, zone II flexor tendon repair with multistrand technique, incision and drainage of the flexor tendon sheath for flexor tenosynovitis, flexor tendon sheath steroid injection, and open cubital tunnel release. Surgical educators need to develop objective methods to teach and document technical skill. The Objective Structured Assessment of Technical Skill is a valid method for accomplishing this task. There has been no consensus regarding which hand surgery procedures should be mastered by graduating plastic surgery residents. The authors have identified nine procedures that are overwhelmingly supported by plastic surgery program directors. These nine procedures can be used as a guideline for developing Objective Structured Assessment of Technical Skill to teach and document technical skills in hand surgery.

  18. A repeated carpal tunnel syndrome due to tophaceous gout in flexor tendon: A case report.

    Science.gov (United States)

    Lu, Hui; Chen, Qiang; Shen, Hui

    2017-03-01

    Gouty tophi is a rare cause of CTS. We first report a unique case of repeated CTS with gouty tophi in flexor tendon. In the previous literature, the symptoms cases of CTS were gradually increased. We report a 44-year-old male porter presented with mass on his left distal forearm combined a repeated carpal tunnel syndrome for 5 years. He felt numbness in fingers and his left palmar. The CTS symptoms had been eased through rest and dugs medication. It recurred twice. Monosodium urate crystal deposits were found in surgery. Histologic findings confirmed the diagnosis of gout. We removed partial of gouty tophus and retained the integrity of the tendon. Two years after the surgery, the patient had not experienced any symptom recurrence. Early diagnosis and control of gout are necessary to avoid irreversible complications. The surgery combined with decreasing trioxypurine treatment can improve the treatment outcome of gouty tophus.

  19. Effects of training on collagen fibril populations in the suspensory ligament and deep digital flexor tendon of young thoroughbreds.

    Science.gov (United States)

    Patterson-Kane, J C; Firth, E C; Parry, D A; Wilson, A M; Goodship, A E

    1998-01-01

    To determine the effect of a specific galloping exercise regimen on collagen fibril mass-average diameters (MAD) in the deep digital flexor tendon (DDFT) and suspensory ligament (SL) of young Thoroughbreds. 12 Thoroughbred fillies, 21 +/- 1 (mean +/- SD) months old. 6 horses underwent a specific 18-month treadmill training program involving galloping exercise. The remaining 6 horses served as controls, undertaking low-volume walking exercise over the same period. Sections were excised from the midpoint of the DDFT and SL, and small strips were dissected from central and peripheral locations for each structure. Fibril diameters were measured from micrographs of transverse ultrathin sections, using a computerized image analysis program. An MAD value was calculated for the central and peripheral regions of the DDFT and SL for each horse. Values for both regions were compared between exercised and control horses. The MAD did not change significantly with exercise for either the DDFT or the SL. Loading of the DDFT as a result of this exercise regimen was not sufficient to stimulate collagen fibril hypertrophy, in keeping with current data that indicate this tendon, compared with the SL and superficial digital flexor tendon (SDFT), is subjected to low loads. Microtrauma, in terms of reduction in fibril MAD, may have occurred in the SL at a site different from that sampled. Another possibility is that, between the trot and the gallop, loading of the SL does not increase to the same extent as that of the SDFT.

  20. Effects of Volar Tilt, Wrist Extension, and Plate Position on Contact Between Flexor Pollicis Longus Tendon and Volar Plate.

    Science.gov (United States)

    Wurtzel, Caroline N Wolfe; Burns, Geoffrey T; Zhu, Andy F; Ozer, Kagan

    2017-12-01

    Volar plates positioned at, or distal to, the watershed line have been shown to have a higher incidence of attritional rupture of the flexor pollicis longus (FPL). In this study, we aimed to evaluate the effect of wrist extension and volar tilt on the contact between the plate and the FPL tendon in a cadaver model. We hypothesized that, following volar plate application, loss of native volar tilt increases the contact between the FPL and the plate at lower degrees of wrist extension. A volar locking plate was applied on 6 fresh-frozen cadavers. To determine the contact between the plate and the FPL tendon, both structures were wrapped with copper wire and circuit conductivity was monitored throughout wrist motion. A lateral wrist radiograph was obtained at each circuit closure, indicating tendon-plate contact. Baseline measurements were obtained with plate positioned at Soong grades 0, 1, and 2. An extra-articular osteotomy was made and contact was recorded at various volar tilt angles (+5°, 0°, -5°, -10°, -15°, and -20°) in 3 different plate positions. A blinded observer measured the degree of wrist extension on all lateral radiographs. Data were analyzed using linear mixed-effects regression model. Plates placed distal to the watershed line had the most contact throughout wrist range of motion. Significantly, less wrist extension was required for contact in wrists with neutral or dorsal tilt and in distally placed volar plates. Volar tilt, wrist extension, and plate position were 3 independent risk factors determining contact between plate and tendon. Loss of volar tilt, increased wrist extension, and higher Soong grade plate position result in greater contact between wire-wrapped FPL tendon and plate. The FPL/plate contact chart generated in this study may be used to assess the risk of rupture in the clinical setting. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  1. Tenosinovitis flexora piógena de la mano: hallazgos ecográficos Pyogenic flexor tenosynovitis of the hand: sonographic findings

    Directory of Open Access Journals (Sweden)

    A. Rodríguez

    2007-09-01

    Full Text Available Los autores describen los hallazgos ecográficos en tres pacientes con tenosinovitis flexora piógena (TFP de la mano. Los hallazgos patológicos encontrados en el Eco-Doppler Color fueron un halo hipoecogénico peritendinoso y una hipervascularización de la vaina sinovial. La Ecografía es un procedimiento no invasivo que permite diagnosticar de manera eficiente y precoz la TFP y permite además realizar un estadiaje preoperatorio siendo una guía útil para planificar la cirugía en función de la cantidad y localización de la colección purulenta y de la integridad tendinosa.The authours describe the sonographic findings in three cases of pyogenic flexor tenosynovitis of the hand. Hipoechogenic peritendinous area and hipervascularization of the synovial sheath revealed as the pathologic findings. In Color Doppler US Ultrasound is a non-invasive procedure that allows to make an accurate and early diagnosis of pyogenic flexor tenosynovitis, it is an useful guide for planning surgery taking account the amount and localization of the purulence and the integrity of the tendons.

  2. Relevância da ultra-sonografia dos tendões flexores em cavalos Puro Sangue de corrida na adaptação ao treinamento Significance of flexor tendon ultrasonography in training thoroughbred horses

    Directory of Open Access Journals (Sweden)

    Carolina Roxana Greig

    2005-08-01

    Full Text Available Vinte e quatro potros Puro Sangue de Corrida (PSC, com dois anos de idade foram avaliados ultra-sonograficamente, durante o período final da doma e início de treinamento, através da imagem transversal dos tendões flexor digital superficial (TFDS e profundo (TFDP. As avaliações foram realizadas com intervalos de 15 dias. A área transversal (AT, a textura dos ecos e a ecogenicidade dos tendões foram avaliadas nas sete zonas da região metacarpiana através de um programa de mensuração de imagens do próprio aparelho de ultra-sonografia. Durante a doma e treinamento, houve diminuição da AT na zona IA e IIIA (PThe cross-sectional area (CSA of the superficial digital flexor tendon (SDFT and deep digital flexor tendon (DDFT of twenty four thoroughbreds was ultrasonographically evaluated before and during their initial training to determine the effect of exercise on the tendon CSA, texture and echogenicity to characterize the response to training. Ultrasonographic transverse images of the left forelimb were obtained every fifteen days. The SDFT CSA of zones IA and IIIA showed a decrease (P<0.05, f=0.010 e f=0.023 res. during the breaking and training period and an increase (P< 0.05 of zone IIIC (f=0.039. Evaluating just the training period, SDFT CSA results of zones IA, IIIA and IIIC were similar. The DDFT showed no variation during the breaking phase but when the training phase was evaluated there was a decrease (P<0.05 in zones IA (f=0.006 and IIIA (f=0.006. Evaluating both breaking and training periods the DDFT showed a decrease (P<0.05 in zones IA (f=0.027, IIIA (f=0.0001 and IIIB (f=0.0031. Fiber texture and tendon echogenicity showed no significant difference between breaking and last reading during training. This study provides evidence of variation of adaptation among the ultrasonographic zones of both SDFT and DDFT to exercise during training of thoroughbred horses. Ultra-sonography is not the most indicated method to evaluate the

  3. Flexor Digitorum Accessorius Longus: Importance of Posterior Ankle Endoscopy

    Directory of Open Access Journals (Sweden)

    Jorge Pablo Batista

    2015-01-01

    Full Text Available Endoscopy for the posterior region of the ankle through two portals is becoming more widespread for the treatment of a large number of conditions which used to be treated with open surgery years ago. The tendon of the flexor hallucis longus (FHL travels along an osteofibrous tunnel between the posterolateral and posteromedial tubercles of the talus. Chronic inflammation of this tendon may lead to painful stenosing tenosynovitis. The aim of this report is to describe two cases depicting an accessory tendon which is an anatomical variation of the flexor hallucis longus in patients with posterior friction syndrome due to posterior ankle impingement and associated with a posteromedial osteochondral lesion of the talus. The anatomical variation (FDAL described was a finding during an endoscopy of the posterior region of the ankle, and we have spared it by sectioning the superior flexor retinaculum only. The accessory flexor digitorum longus is an anatomical variation and should be taken into account when performing an arthroscopy of the posterior region of the ankle. We recommend this treatment on this type of injury although we admit this does not make a definite conclusion.

  4. Miscellaneous conditions of tendons, tendon sheaths, and ligaments.

    Science.gov (United States)

    Dyson, S J; Dik, K J

    1995-08-01

    The use of diagnostic ultrasonography has greatly enhances our ability to diagnose injuries of tendons and tendon sheaths that were previously either unrecognized or poorly understood. For may of these injuries, there is currently only a small amount of follow-up data. This article considers injuries of the deep digital flexor tendon and its accessory ligament, the carpal tunnel syndrome soft tissue swellings on the dorsal aspect of the carpus, intertubercular (bicipital) bursitis and bicipital tendinitis, injuries of the gastrocnemius tendon, common calcaneal tendinitis, rupture of peroneus (fibularis tertius) and ligaments injuries of the back.

  5. Three-dimensional Doppler ultrasound findings in healthy wrist and finger tendon sheaths

    DEFF Research Database (Denmark)

    Ammitzboll-Danielsen, Mads; Janta, Iustina; Torp-Pedersen, Søren

    2016-01-01

    interpretation of Doppler signals when diagnosing tenosynovitis. Method Forty healthy participants (20 women and 20 men age 23-67 years) without prior history of arthritis, tendon diseases or present pain in their hands were included. Twenty participants had 3D Doppler US of the second and third finger...... participant. No significant difference in feeding vessels was seen between the radial and carpal level in the wrist (p = 0.06) or between the second and third flexor tendon sheath (p = 0.84). Conclusion Doppler findings in or in close proximity to the tendon sheaths were common in wrists and fingers...

  6. Flexor Tenosynovitis Due to Tuberculosis in Hand and Wrist: Is Tenosynovectomy Imperative?

    Science.gov (United States)

    Kabakaş, Fatih; Uğurlar, Meriç; Turan, Derya Bayirli; Yeşiloğlu, Nebil; Mersa, Berkan; Özçelik, İsmail Bülent

    2016-08-01

    The treatment of flexor tenosynovitis in the hand and wrist due to tuberculosis is controversial. Although some authors recommend the antituberculous chemotherapy, the others recommend the surgical treatment. In this article, 12 patients with synovial tuberculosis of the flexor aspect of the hand and the wrist were evaluated with respect to diagnosis and treatment modalities. None of the patients had a history of tuberculosis, concomitant disease, immunosuppressive drug use, drug abuse, and human immunodefficiency virus positivity. A chest x-ray and family screening were performed in all of the cases, none had evidence of tuberculosis in the lung. The biopsy, histopathological examination, acid-fast bacillus staining, and BACTEC tuberculosis culture were performed. Antituberculous chemotherapy was initiated in patients diagnosed with tuberculosis by either histological or microbiological examinations. The patients did not undergo any further surgery after biopsy procedures. The lesions regressed totally in all patients after 3 months of treatment. Carpal tunnel syndrome symptoms and signs recruited at five months of treatment. In patients with flexor tuberculosis tenosynovitis, it is possible to achieve good results by applying only medical therapy after a biopsy, and without the need for further surgery.

  7. Arthroscopic Release of Flexor Hallucis Longus Tendon Sheath in Female Ballet Dancers: Dynamic Pathology, Surgical Technique, and Return to Dancing Performance.

    Science.gov (United States)

    Funasaki, Hiroki; Hayashi, Hiroteru; Sakamoto, Kanako; Tsuruga, Rei; Marumo, Keishi

    2015-12-01

    Stenosing tenosynovitis of the flexor hallucis longus (FHL) tendon is known as a major overuse lesion in female dancers. We describe arthroscopic surgical techniques in relation to the dynamic pathology of the disease. Crepitus and pain on moving the great toe with the ankle in plantar flexion on preoperative examination confirm the diagnosis of FHL stenosing tenosynovitis even if the os trigonum is not evident. The ankle is approached through standard posterolateral and posteromedial portals. A 4.0-mm-diameter 30° arthroscope is used. Soft tissues around the talus are cleared with a motorized shaver and a radiofrequency device. The posterior aspects of the talus, os trigonum, and FHL tendon surrounded by the tendon sheath are visualized. The dynamic pathology of the FHL tendon is well observed on passive motion of the great toe. The prominent bone fragment of the talus is removed and the tendon sheath is cut with a retrograde knife and a motorized shaver from the superior border down to the entrance of the fibro-osseous tunnel. Arthroscopic release of the FHL tendon sheath is a useful and easy method to directly approach the dynamic pathology of FHL tenosynovitis in female ballet dancers.

  8. Flexor Hallucis Longus tendon rupture in RA-patients is associated with MTP 1 damage and pes planus

    Directory of Open Access Journals (Sweden)

    Buurke Jaap J

    2007-11-01

    Full Text Available Abstract Background To assess the prevalence of and relation between rupture or tenosynovitis of the Flexor Hallucis Longus (FHL tendon and range of motion, deformities and joint damage of the forefoot in RA patients with foot complaints. Methods Thirty RA patients with painful feet were analysed, their feet were examined clinically for the presence of pes planus and range of motion (ROM, radiographs were scored looking for the presence of forefoot damage, and ultrasound examination was performed, examining the presence of tenosyovitis or rupture of the FHL at the level of the medial malleolus. The correlation between the presence or absence of the FHL and ROM, forefoot damage and pes planus was calculated. Results In 11/60(18% of the feet, a rupture of the FHL was found. This was associated with a limited motion of the MTP1-joint, measured on the JAM (χ2 = 10.4, p = 0.034, a higher prevalence of pes planus (χ2 = 5.77, p = 0.016 and a higher prevalence of erosions proximal at the MTP-1 joint (χ2 = 12.3, p = 0.016, and joint space narrowing of the MTP1 joint (χ2 = 12.7, p = 0.013. Conclusion Rupture of the flexor hallucis longus tendon in RA-patients is associated with limited range of hallux motion, more erosions and joint space narrowing of the MTP-1-joint, as well as with pes planus.

  9. Effect of laceration and trimming of a tendon on the coefficient of friction along the A2 pulley: an in vitro study on turkey tendon.

    Science.gov (United States)

    Hajipour, L; Gulihar, A; Dias, J

    2010-08-01

    We carried out lacerations of 50%, followed by trimming, in ten turkey flexor tendons in vitro and measured the coefficient of friction at the tendon-pulley interface with loads of 200 g and 400 g and in 10 degrees , 30 degrees, 50 degrees and 70 degrees of flexion. Laceration increased the coefficient of friction from 0.12 for the intact tendon to 0.3 at both the test loads. Trimming the laceration reduced the coefficient of friction to 0.2. An exponential increase in the gliding resistance was found at 50 degrees and 70 degrees of flexion (p = 0.02 and p = 0.003, respectively) following trimming compared to that of the intact tendon. We concluded that trimming partially lacerated flexor tendons will reduce the gliding resistance at the tendon-pulley interface, but will lead to fragmentation and triggering of the tendon at higher degrees of flexion and loading. We recommend that higher degrees of flexion be avoided during early post-operative rehabilitation following trimming of a flexor tendon.

  10. Multiple Tophaceous Gout of Hand with Extensor Tendon Rupture

    Directory of Open Access Journals (Sweden)

    Haruki Tobimatsu

    2017-01-01

    Full Text Available A 45-year-old man presented with painless subcutaneous masses bilaterally on his hands and loss of motion or contracture of the fingers. Initially, drug therapy to reduce the serum uric acid was administered and was expected to reduce the tophi. However, during observation at the clinic, spontaneous rupture of an extensor tendon occurred, and surgical repair of the tendon and resection of the masses were performed. Surgical exploration of the right hand showed hypertrophic white-colored crystal deposits that both surrounded and invaded the extensor digitorum communis of the index finger, which was ruptured. Histopathologic examination of the specimen demonstrated findings consistent with gouty tophi. Tophaceous gout can induce a rupture of tendons during clinical observation, and surgical resection of the tophi might be needed to prevent ruptures.

  11. Giant Cell Tumour of Tendon Sheath Masquerading As Trigger Finger

    Directory of Open Access Journals (Sweden)

    N Rahimawati

    2010-11-01

    Full Text Available We report a case of a 59-year-old female who presented in the general orthopaedic clinic with triggering of her right middle finger. She did not respond to conventional treatment methods; subsequently she underwent surgical open release under local anaesthesia. Five months postoperatively, the patient presented with signs and symptoms of acute flexor tenosynovitis, and was thought to have a postoperative infection. Re-examination by a hand surgeon raised the possibility of a different aetiology. Based on clinical findings and response to initial treatment, giant cell tumour of the flexor tendon sheath was suspected and later confirmed following surgical biopsy. A high index of suspicion and knowledge of the variegated presentations of giant cell tumour in the hand are beneficial in these types of cases.

  12. Incidence and Association of CT Findings of Ankle Tendon Injuries in Patients Presenting With Ankle and Hindfoot Fractures.

    Science.gov (United States)

    Golshani, Ashkahn; Zhu, Liang; Cai, Chunyan; Beckmann, Nicholas M

    2017-02-01

    Tendon injuries are a commonly encountered finding in ankle CT examinations performed for fractures. This study was designed to identify the incidence and associations of tendon injuries in ankle CT examinations performed for fractures. A retrospective review was performed of 410 patients who underwent ankle CT during a 6-year period. Tendon injuries were common, seen in 25% of all ankle CT examinations. Tendon subluxation-dislocation accounted for most of the tendon injuries (77 of 196 total injuries). Pilon fractures carried 2.2 times increased risk of tibialis posterior tendon injury (p = 0.0094). Calcaneus fractures carried 11.86 times increased risk of peroneus brevis tendon and 10.71 times increased risk of peroneus longus tendon injury (p < 0.0001). Calcaneus fractures also carried 5.21 times increased risk of flexor hallucis longus tendon injury (p = 0.0024). Talus fracture was associated with injury to all flexor compartment tendons. Talus fractures carried 3.43 times increased risk of tibialis posterior tendon injury (p < 0.0001), 4.51 times increased risk of flexor digitorum longus tendon injury (p = 0.0005), and 6.97 times increased risk of flexor hallucis longus tendon injury (p < 0.0001). Calcaneal fractures are prone to peroneal tendon injury, and talus fractures are prone to flexor tendon injury. In patients with pilon fractures, it is important to look for tibialis posterior tendon injury, specifically for entrapment. Overall, the most common type of injury is tendon malalignment, so it is imperative to know the normal tendon paths and associated bony landmarks to identify tendon injury.

  13. Biochemical characterisation of navicular hyaline cartilage, navicular fibrocartilage and the deep digital flexor tendon in horses with navicular disease.

    Science.gov (United States)

    Viitanen, M; Bird, J; Smith, R; Tulamo, R-M; May, S A

    2003-10-01

    The study hypothesis was that navicular disease is a process analogous to degenerative joint disease, which leads to changes in navicular fibrocartilage and in deep digital flexor tendon (DDFT) matrix composition and that the process extends to the adjacent distal interphalangeal joint. The objectives were to compare the biochemical composition of the navicular articular and palmar cartilages from 18 horses with navicular disease with 49 horses with no history of front limb lameness, and to compare navicular fibrocartilage with medial meniscus of the stifle and collateral cartilage of the hoof. Cartilage oligomeric matrix protein (COMP), deoxyribonucleic acid (DNA), total glycosaminoglycan (GAG), metalloproteinases MMP-2 and MMP-9 and water content in tissues were measured. Hyaline cartilage had the highest content of COMP and COMP content in hyaline cartilage and tendon was higher in lame horses than in sound horses (phyaline cartilage was higher in lame horses than in sound horses. The MMP-2 amounts were significantly higher in tendons compared to other tissue types. Overall, 79% of the lame horses with lesions had MMP-9 in their tendons and the amount was higher than in sound horses (phyaline and fibrocartilage as well as the DDFT with potential implications for the pathogenesis and management of the condition.

  14. Magnetic resonance imaging of the pulleys of the flexor tendons of the toes at 11.7 T

    Energy Technology Data Exchange (ETDEWEB)

    Tafur, Monica; Iwasaki, Kenyu; Statum, Sheronda; Szeverenyi, Nikolaus M.; Bydder, Graeme M. [University of California, San Diego, School of Medicine, Department of Radiology, San Diego, CA (United States); Chung, Christine B. [Department of Radiology, Veterans Administration San Diego Healthcare System, San Diego, CA (United States); University of California, San Diego, School of Medicine, Department of Radiology, San Diego, CA (United States)

    2015-01-15

    We obtained high-resolution 11.7-T MR images of the pulleys of the flexor tendons in cadaveric toe specimens. A detailed understanding of toe pulley anatomy as seen with MR is likely to be of benefit in recognizing disease and the effects of trauma. Six cadaveric toes were imaged with an 11.7-T small-bore MR imaging system using optimized coils. Two-dimensional dual-echo SE scans were obtained in three planes (40 x 40 x 400-μm{sup 3} voxel size, TE = 7/14 ms, TR = 3,500 ms, fat saturation). Three-dimensional spoiled gradient echo scans were obtained (90-150 μm{sup 3} isotropic voxel size, TE = 6 ms, TR = 25 ms, with and without fat saturation). Specimen orientation was with the long axis of the toe either parallel or perpendicular to B{sub 0}. All the annular (A) pulleys were demonstrated in the great and lesser toes. The A2 pulley in the great and lesser toes and the A4 pulley in the lesser toes were the most substantial pulleys. The A5 pulley, which has not previously been described in the toes, was demonstrated. The cruciform pulleys were also seen and were smaller and thinner. Three tissue layers were seen, and there was evidence of different fiber directions in annular pulleys producing different magic angle effects. Detailed anatomy of the pulley system of the flexor tendons was seen on the 11.7-T MR images showing new features and providing a basis for image interpretation. Similarities and differences between the pulley systems in the toes and the fingers were identified. (orig.)

  15. Investigation of index finger triggering force using a cadaver experiment: Effects of trigger grip span, contact location, and internal tendon force.

    Science.gov (United States)

    Chang, Joonho; Freivalds, Andris; Sharkey, Neil A; Kong, Yong-Ku; Mike Kim, H; Sung, Kiseok; Kim, Dae-Min; Jung, Kihyo

    2017-11-01

    A cadaver study was conducted to investigate the effects of triggering conditions (trigger grip span, contact location, and internal tendon force) on index finger triggering force and the force efficiency of involved tendons. Eight right human cadaveric hands were employed, and a motion simulator was built to secure and control the specimens. Index finger triggering forces were investigated as a function of different internal tendon forces (flexor digitorum profundus + flexor digitorum superficialis = 40, 70, and 100 N), trigger grip spans (40, 50, and 60 mm), and contact locations between the index finger and a trigger. Triggering forces significantly increased when internal tendon forces increased from 40 to 100 N. Also, trigger grip spans and contact locations had significant effects on triggering forces; maximum triggering forces were found at a 50 mm span and the most proximal contact location. The results revealed that only 10-30% of internal tendon forces were converted to their external triggering forces. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Acute Hemorrhagic Flexor Tenosynovitis due to Vincula Injury

    Science.gov (United States)

    Maher, Rory

    2015-01-01

    Summary: A 20-year-old previously well woman presented to the emergency department with classical signs of acute flexor tenosynovitis, 4 hours after a minor puncture wound over the volar aspect of her right middle finger distal interphalangeal joint. Exploration of the flexor sheath in theatre revealed frank blood within the sheath and extension of the puncture wound through the profundus tendon into the short vincula beneath. The blood was irrigated from the sheath, and the patient made a complete recovery by 2 weeks postoperatively. Although rare, irritation and distension of the flexor sheath caused by vincular hemorrhage can be an alternative mechanism for the development of acute flexor tenosynovitis, and as with pyogenic flexor tenosynovitis, prompt surgical treatment can minimize the risk of long-term functional impairment. PMID:26301147

  17. Avaliação do resultado da reconstrução artroscópica do ligamento cruzado anterior do joelho com enxerto dos tendões flexores Evaluation of the results of arthroscopic ACL reconstruction with autogenous flexor tendons

    Directory of Open Access Journals (Sweden)

    Alexandre Almeida

    2010-01-01

    Full Text Available OBJETIVO: Avaliar o resultado da reconstrução do ligamento cruzado anterior (LCA com o autoenxerto dos tendões flexores da coxa. Serão analisados os dados com relação ao sexo, ao índice de massa corporal (IMC e a associação com fratura no membro inferior (MI. MÉTODOS: Foi analisado um grupo de 265 pacientes submetidos à artroscopia do joelho para fins de reconstrução do LCA com enxerto ipsilateral dos tendões flexores da coxa no período de 6 de julho de 2000 a 19 de novembro de 2007. RESULTADOS: 176 pacientes foram avaliados com média de 34,95 ± 18,8 meses (mediana 31 meses (IIQ: 20-48 meses. A avaliação mínima foi aos 12 meses e a máxima aos 87 meses. Obtivemos 138 (78,4% pacientes com resultado excelente, 22 (12,5% com resultado bom, oito (4,5% com resultado regular e oito (4,5% pacientes apresentaram resultado ruim. Não foi considerada significativa a maior incidência de bons e excelentes resultados para o sexo masculino (p = 0,128, para os pacientes com IMC OBJETIVE: To evaluate the results of single band arthroscopic anterior cruciate ligament (ACL reconstruction with flexor tendon autografts. We analyzed data about sex, body mass index (BMI and lower limb fracture associated with the initial trauma. METHODS: Two hundred and sixty-five patients who underwent arthroscopic anterior cruciate ligament (ACL reconstruction with ipsilateral thigh flexor tendon autografts from July 6, 2000, to November 19, 2007, were evaluated. RESULTS: One hundred and seventy-six patients were evaluated at an average follow up time of 34.95 ± 18.8 months (Median 31 months (IIQ: 20 - 48 months. The minimum evaluation time was 12 months and the maximum 87 months. One hundred and thirty-eight (78.4% patients had excellent results, 22 (12.5% patients good, 8 (4.5% patients fair, and 8 (4.5% poor results. No statistical significance was found for the better results for males (p = 0.128, for patients with a BMI < 25 (p = 0.848, or for patients

  18. Stenosing Tenosynovitis of the Flexor Hallucis Longus Tendon Associated with the Plantar Capsular Accessory Ossicle at the Interphalangeal Joint of the Great Toe

    Directory of Open Access Journals (Sweden)

    Song Ho Chang

    2017-01-01

    Full Text Available This report presents a case of stenosing tenosynovitis of the flexor hallucis longus tendon associated with the plantar capsular accessory ossicle at the interphalangeal joint of the great toe, which was confirmed by intraoperative observation and was successfully treated with surgical resection of the ossicle. As the plantar capsular accessory ossicle was not visible radiographically due to the lack of ossification, ultrasonography was helpful for diagnosing this disorder.

  19. A group of patients with Marfan's syndrome, who have finger and toe contractures, displays tendons' alterations upon an ultrasound examination: are these features common among classical Marfan patients?

    Science.gov (United States)

    Melchiorre, Daniela; Pratelli, Elisa; Torricelli, Elena; Sofi, Francesco; Abbate, Rosanna; Matucci-Cerinic, Marco; Gensini, GianFranco; Pepe, Guglielmina

    2016-08-01

    The involvement of the musculoskeletal system with other mild pleiotropic manifestations represents a clinical criterion, called "systemic features," to d iagnose Marfan's syndrome. We aimed to investigate the features of the hands and feet redressable contractures present in a group of Marfan patients. In 13 patients with previously diagnosed Marfan's syndrome, an accurate clinical examination was performed. In particular the characterization of the musculoskeletal system by visual analogic scale to measure muscle pain (VAS) and muscle strength (MRC system) was carried out; the Beighton scale score was used to evaluate the articular hypermobility. Ultrasound examination (US) was performed to detect deep-superficial flexor tendons and extensor tendons of both hands, and the short and long flexor and extensor tendons of the fingers and toes in static and dynamic positions. The ImageJ program was adopted to measure a profile of tendon echo-intensity. A reduction of the thickness of all tendons was detected by US in our patients; the VAS and Beighton scale scores were in normal ranges. The profile of tendon echo-intensity showed different textural details in all Marfan patients. This study provides evidence for other contractures' localization, and for altered findings of the tendons in patients with Marfan syndrome and finger/toe contractures. These changes may be associated with structural modifications in connective tissue.

  20. Concept development of a tendon arm manipulator and anthropomorphic robotic hand

    Science.gov (United States)

    Tolman, C. T.

    1987-01-01

    AMETEK/ORED inhouse research and development efforts leading toward a next-generation robotic manipulator arm and end-effector technology is summarized. Manipulator arm development has been directed toward a multiple-degree-of-freedom, flexible, tendon-driven concept referred to here as a Tendon Arm Manipulator (TAM). End-effector development has been directed toward a three-fingered, dextrous, tendon-driven, anthropomorphic configuration which is referred to as an Anthropomorphic Robotic Hand (ARH). Key technology issues are identified for both concepts.

  1. Microstructural stress relaxation mechanics in functionally different tendons.

    Science.gov (United States)

    Screen, H R C; Toorani, S; Shelton, J C

    2013-01-01

    Tendons experience widely varying loading conditions in vivo. They may be categorised by their function as either positional tendons, which are used for intricate movements and experience lower stress, or as energy storage tendons which act as highly stressed springs during locomotion. Structural and compositional differences between tendons are thought to enable an optimisation of their properties to suit their functional environment. However, little is known about structure-function relationships in tendon. This study adopts porcine flexor and extensor tendon fascicles as examples of high stress and low stress tendons, comparing their mechanical behaviour at the micro-level in order to understand their stress relaxation response. Stress-relaxation was shown to occur predominantly through sliding between collagen fibres. However, in the more highly stressed flexor tendon fascicles, more fibre reorganisation was evident when the tissue was exposed to low strains. By contrast, the low load extensor tendon fascicles appears to have less capacity for fibre reorganisation or shearing than the energy storage tendon, relying more heavily on fibril level relaxation. The extensor fascicles were also unable to sustain loads without rapid and complete stress relaxation. These findings highlight the need to optimise tendon repair solutions for specific tendons, and match tendon properties when using grafts in tendon repairs. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  2. Influence of track surface on the equine superficial digital flexor tendon loading in two horses at high speed trot.

    Science.gov (United States)

    Crevier-Denoix, N; Pourcelot, P; Ravary, B; Robin, D; Falala, S; Uzel, S; Grison, A C; Valette, J P; Denoix, J M; Chateau, H

    2009-03-01

    Although track surfaces are a risk factor of tendon injuries, their effects on tendon loading at high speed are unknown. Using a noninvasive ultrasonic technique, it is now possible to evaluate the forces in the superficial digital flexor tendon (SDFT) in exercise conditions. To compare the effects of an all-weather waxed track (W) vs. a crushed sand track (S), on the SDFT loading in the trotter horse at high speed. Two trotter horses were equipped with the ultrasonic device (1 MHz ultrasonic probe, fixed on the palmar metacarpal area of the right forelimb). For each trial, data acquisition was made at 400 Hz and 10 consecutive strides were analysed. In each session, the 2 track surfaces were tested in a straight line. The speed was imposed at 10 m/s and recorded. The right forelimb was also equipped with a dynamometric horseshoe and skin markers. The horse was filmed with a high-speed camera (600 Hz); all recordings were synchronised. Statistical differences were tested using the GLM procedure (SAS; P < 0.05). Maximal tendon force was significantly lower on W compared with S. In addition to maximal force peaks around mid-stance, earlier peaks were observed, more pronounced on S than on W, at about 13% (horse 2) and 30% (both horses) of the stance phase. Comparison with kinematic data revealed that these early peaks were accompanied by plateaux in the fetlock angle-time chart. For high tendon forces, the tendon maximal loading rate was significantly lower on W than on S. CONCLUSIONS AND POTENTIAL CLINICAL RELEVANCE: The all-weather waxed track appears to induce a lesser and more gradual SDFT loading than crushed sand. The SDFT loading pattern at high speed trot suggests proximal interphalangeal joint movements during limb loading.

  3. Flexor accessorius longus: A rare variation of the deep extrinsic digital flexors of the leg and its phylogenetic significance

    Directory of Open Access Journals (Sweden)

    Jaijesh P

    2006-01-01

    Full Text Available Anomalies of the calf muscles are rare. One such anomalous muscle, known as the Muscle Flexor accessorius longus (also named accessorius ad accessorium, accessorius secondus, accessory flexor digitorum longus or pronator pedis is of morphological significance. When present, this originates in the deep fascia of the tibia or fibula and inserts in the foot either into the flexor digitorum accessorius or into the tendons of the flexor digitorum longus. In this report we present a discussion of the morphological significance and phylogenetic history of one such muscle observed. In this case report we describe an anomalous calf muscle which extends from the popliteal region, runs along the posterior compartment of the leg, reaches the sole and is inserted to the flexor digitorum longus muscle. This kind of muscle variations are considered to be the higher origin of the flexor digitorum accessorius muscle of the sole. Here we discuss the phylogenetic history of this muscle as this muscle variant is present in some primitive mammals, absent in apes and in this particular case appeared as one of the muscles of the flexor compartment of the leg.

  4. Point-of-Care Ultrasound in the Evaluation of Pyogenic Flexor Tenosynovitis.

    Science.gov (United States)

    Cohen, Stephanie G; Beck, Sierra C

    2015-11-01

    A 4-year-old girl presented to the emergency department for evaluation of finger swelling after a dog bite. Point-of-care ultrasound was used to diagnose pyogenic flexor tenosynovitis of the digit after visualizing a fluid collection within the flexor tendon sheath. The patient underwent emergent incision and drainage of the digit with good outcome.

  5. Comparative anatomy of rabbit and human achilles tendons with magnetic resonance and ultrasound imaging.

    Science.gov (United States)

    Doherty, Geoffrey P; Koike, Yoichi; Uhthoff, Hans K; Lecompte, Martin; Trudel, Guy

    2006-02-01

    We sought to describe the comparative anatomy of the Achilles tendon in rabbits and humans by using macroscopic observation, magnetic resonance imaging, and ultrasonography. The calcaneus-Achilles tendon-gastrocnemius-soleus complexes from 18 New Zealand white rabbits underwent ultrasound (US) and magnetic resonance (MR) imaging and gross anatomic sectioning; these results were compared with those from a cadaveric gastrocnemius-soleus-Achilles tendon-calcaneus specimen from a 68-y-old human male. The medial and lateral gastrocnemius muscle tendons merged 5.2 +/- 0.6 mm proximal to the calcaneal insertion macroscopically, at 93% of their course, different from the gastrocnemius human tendons, which merged at 23% of their overall course. The rabbit flexor digitorum superficialis tendon, corresponding to the flexor digitorum longus tendon in human and comparable in size with the gastrocnemius tendons, was located medial and anterior to the medial gastrocnemius tendon proximally and rotated dorsally and laterally to run posterior to the Achilles tendon-calcaneus insertion. In humans, the flexor digitorum longus tendon tracks posteriorly to the medial malleolus. The soleus muscle and tendon are negligible in the rabbit; these particular comparative anatomic features in the rabbit were confirmed on the MR images. Therefore the rabbit Achilles tendon shows distinctive gross anatomical and MR imaging features that must be considered when using the rabbit as a research model, especially for mechanical testing, or when generalizing results from rabbits to humans.

  6. Bilateral Posterior Tibial Tendon and Flexor Digitorum Longus Dislocations.

    Science.gov (United States)

    Padegimas, Eric M; Beck, David M; Pedowitz, David I

    2017-04-01

    The authors present a case of a previously healthy and athletic 17-year-old female who presented with a 3.5-year history of medial left ankle pain after sustaining an inversion injury while playing basketball. Prior to presentation, she had failed prior immobilization and physical therapy for a presumed ankles sprain. Physical examination revealed a dislocated posterior tibial tendon (PTT) that was temporarily reducible, but would spontaneously dislocate immediately after reduction. She had pain and snapping of the PTT with resisted ankle plantar flexion and resisted inversion as well as 4/5 strength in ankle inversion. The diagnosis of dislocated PTT was confirmed on magnetic resonance imaging (MRI). The patient underwent suture anchor repair of the medial retinaculum of the left ankle. At the time of surgery both the PTT and flexor digitorum longus (FDL) were dislocated. Three months postoperatively, the patient represented with PTT dislocation of the right (nonoperative) ankle confirmed by MRI. After failure of immobilization, physical therapy, and oral anti-inflammatory medications, the patient underwent suture anchor repair of the medial retinaculum of the right ankle. At 6 months postoperatively, the patient has 5/5 strength inversion bilaterally, no subluxation of either PTT, and has returned to all activities without limitation. The authors present this unique case of bilateral PTT dislocation and concurrent PTT/FDL dislocation along with review of the literature for PTT dislocation. The authors highlight the common misdaiganosis of this injury and highlight the successful results of surgical intervention. Level V: Case report.

  7. Anatomical feasibility study of flexor hallucis longus transfer in treatment of Achilles tendon and posteromedial portal of ankle arthroscopy.

    Science.gov (United States)

    Mao, Haijiao; Wang, Linger; Dong, Wenwei; Liu, Zhenxin; Yin, Weigang; Xu, Dachuan; Wapner, Keith L

    2018-04-16

    The aim of this study was to evaluate the occurrence of anatomical variations of the musculotendinous junction of the flexor hallucis longus (FHL) muscle, the relationship between FHL tendon or muscle and the tibial neurovascular bundle at the level of the posterior ankle joint in human cadavers. Seventy embalmed feet from 20 male and 15 female cadavers, the cadavers' mean age was 65.4 (range from 14 to 82) years, were dissected and anatomically classified to observe FHL muscle morphology define the relationship between FHL tendon or muscle and the tibial neurovascular bundle. The distance between the musculotendinous junction and the relationship between FHL tendon or muscle and the tibial neurovascular bundle was determined. Three morphology types of FHL muscle were identified: a long lateral and shorter medial muscle belly, which was observed in 63 specimens (90%); equal length medial and lateral muscle bellies, this variant was only observed in five specimens (7.1%); one lateral and no medial muscle belly, which was observed in two specimens (2.9%). No statistically significant difference was observed according to gender or side (p > 0.05). Two patterns were identified and described between FHL tendon or muscle and the tibial neurovascular bundle. Pattern 1, the distance between the neurovascular bundle and FHL tendon was 3.46 mm (range 2.34-8.84, SD = 2.12) which was observed in 66 specimens (94.3%); Pattern 2, there was no distance which was observed in four specimens (5.7%). Knowing FHL muscle morphology, variations provide new important insights into secure planning and execution of a FHL transfer for Achilles tendon defect as well as for the interpretation of ultrasound and magnetic resonance images. With posterior arthroscopic for the treatment of various ankle pathologies, posteromedial portal may be introduced into the posterior aspect of the ankle without gross injury to the tibial neurovascular structures because of the gap between the

  8. Computer Aided Quantification of Pathological Features for Flexor Tendon Pulleys on Microscopic Images

    Directory of Open Access Journals (Sweden)

    Yung-Chun Liu

    2013-01-01

    Full Text Available Quantifying the pathological features of flexor tendon pulleys is essential for grading the trigger finger since it provides clinicians with objective evidence derived from microscopic images. Although manual grading is time consuming and dependent on the observer experience, there is a lack of image processing methods for automatically extracting pulley pathological features. In this paper, we design and develop a color-based image segmentation system to extract the color and shape features from pulley microscopic images. Two parameters which are the size ratio of abnormal tissue regions and the number ratio of abnormal nuclei are estimated as the pathological progression indices. The automatic quantification results show clear discrimination among different levels of diseased pulley specimens which are prone to misjudgments for human visual inspection. The proposed system provides a reliable and automatic way to obtain pathological parameters instead of manual evaluation which is with intra- and interoperator variability. Experiments with 290 microscopic images from 29 pulley specimens show good correspondence with pathologist expectations. Hence, the proposed system has great potential for assisting clinical experts in routine histopathological examinations.

  9. Comparison of Post Operative Early Active and Passive Mobillization of Flexor Tendon in Zone 2

    Directory of Open Access Journals (Sweden)

    Fereidoun Layeghi

    2003-12-01

    Full Text Available Objective: Despite numerous advances in our understanding of the anatomy, Biomechanics, nutrition and Healing, the result Following Fiewor Tendon repair Shiow relatively high rate of failure the purpost of this study was to compare the result of 50 digits treated by either ‘‘Early active mobilization’’ or ‘‘controlled passive mobilization’’ re gimen in Ivan hand rehabilitation center. Materials & Mathods: Pationt being matched for gende, age, injuries hand, technique of srgery (all with eqitenon first, four strand in two groups. They were assessed 8 week postoperatibg in respect of total active motion, flexion gap and extension lags. Outcome were defined using ‘‘Strickland’’ and ‘’ Buck – Gramko’’ criteria. Results: The result were 80% excellent and good, 20% fair and no poor in early active motion group and in second group 40% excellent and good, 44% fair and 16% poor due to Strickland criteria. In buck-grancko criteria 52% extension and good, 32% fair and 16% were poor. Mean of total active motion was significantly greater in early active motion group (in E.A.M.150/2, in passive group: 116/41. Conclusion: Actively mobilized tendon underwent intrinsic healing without large gap formation. Active motion generated bith tension and motion and offer several advantage over passive motion: improved tendon nutrition, less adhission, higher rate of healing, increased ultimate rang of motion. So early active motion is the best protocle for treating tendons in zons 2 our result is comparable with theory.

  10. Sports Injury-Related Fingers and Thumb Deformity Due to Tendon or Ligament Rupture.

    Science.gov (United States)

    Bai, Rong-Jie; Zhang, Hui-Bo; Zhan, Hui-Li; Qian, Zhan-Hua; Wang, Nai-Li; Liu, Yue; Li, Wen-Ting; Yin, Yu-Ming

    2018-05-05

    Hand injuries are very common in sports, such as skiing and ball sports. One of the major reasons causing hand and finger deformity is due to ligament and tendon injury. The aim of this study was to investigate if the high-resolution 3T magnetic resonance imaging (MRI) can demonstrate the complex anatomy of the fingers and thumb, especially the tendons and ligaments, and provide the accurate diagnosis of clinically important fingers and thumbs deformity due to ligamentous and tendinous injuries during sport activities. Sixteen fresh un-embalmed cadaveric hands were harvested from eight cadavers. A total of 20 healthy volunteers' hands and 44 patients with fingers or thumb deformity due to sports-related injuries were included in this study. All subjects had MR examination with T1-weighted images and proton density-weighted imaging with fat suppression (PD FS) in axial, coronal, and sagittal plane, respectively. Subsequently, all 16 cadaveric hands were sliced into 2-mm thick slab with a band saw (six in coronal plane, six in sagittal plane, and four in axial plane). The correlation of anatomic sections and the MRI characteristics of tendons of fingers and the ulnar collateral ligament (UCL) at the metacarpal phalangeal joint (MCPJ) of thumb between 20 healthy volunteers and 44 patients (confirmed by surgery) were analyzed. The normal ligaments and tendons in 16 cadaveric hands and 20 volunteers' hands showed uniform low-signal intensity on all the sequences of the MRI. Among 44 patients with tendinous and ligamentous injuries in the fingers or thumb, 12 cases with UCL injury at MCPJ of the thumb (Stener lesion = 8 and non-Stener lesion = 4), 6 cases with the central slip injury, 12 cases with terminal tendon injury, and 14 cases with flexor digitorum profundus injury. The ligaments and tendons disruption manifested as increased signal intensity and poor definition, discontinuity, and heterogeneous signal intensity of the involved ligaments and tendons. Sports

  11. Effects of wrist tendon vibration on arm tracking in people poststroke.

    Science.gov (United States)

    Conrad, Megan O; Scheidt, Robert A; Schmit, Brian D

    2011-09-01

    The goal of this study was to evaluate the influence of wrist tendon vibration on a multijoint elbow/shoulder tracking task. We hypothesized that tendon vibration applied at the wrist musculature would improve upper arm tracking performance in chronic stroke survivors through increased, Ia-afferent feedback to the central nervous system (CNS). To test this hypothesis, 10 chronic stroke and 5 neurologically intact subjects grasped the handle of a planar robot as they tracked a target through a horizontal figure-8 pattern. A total of 36 trials were completed by each subject. During the middle trials, 70-Hz tendon vibration was applied at the wrist flexor tendons. Position, velocity, and electromyography data were evaluated to compare the quality of arm movements before, during, and after trials with concurrent vibration. Despite tracking a target that moved at a constant velocity, hand trajectories appeared to be segmented, displaying alternating intervals of acceleration and deceleration. Segments were identifiable in tangential velocity data as single-peaked, bell-shaped speed pulses. When tendon vibration was applied at the wrist musculature, stroke subjects experienced improved tracking performance in that hand path lengths and peak speed variability decreased, whereas movement smoothness increased. These performance improvements were accompanied by decreases in the muscle activity during movement. Possible mechanisms behind improved movement control in response to tendon vibration may include improved sensorimotor integration or improved cortical modulation of spinal reflex activity.

  12. Tendons in the plantar aspect of the foot: MR imaging and anatomic correlation in cadavers

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Rodrigo [University of California San Diego, Radiology, San Diego, CA (United States); Fleury Medical Center, Radiology, Sao Paulo, SP (Brazil); Aguiar, Rodrigo; Trudell, Debra; Resnick, Donald [University of California San Diego, Radiology, San Diego, CA (United States)

    2007-02-15

    The purpose of this anatomic imaging study was to illustrate the normal complex anatomy of tendons of the plantar aspect of the ankle and foot using magnetic resonance (MR) imaging with anatomic correlation in cadavers. Seven fresh cadaveric feet (obtained and used according to institutional guidelines, with informed consent from relatives of the deceased) were studied with intermediate-weighted fast-spin-echo MR imaging. For anatomic analysis, cadaveric specimens were sectioned in 3-mm-thick slices in the coronal and axial planes that approximated the sections acquired at MR imaging. The entire courses of the tendons into the plantar aspect of the foot were analyzed. The tibialis posterior tendon has a complex distal insertion. The insertions in the navicular, second, and third cuneiforms bones were identify in all cases using axial and coronal planes. A tendinous connection between the flexor hallucis longus and the flexor digitorum longus tendons was identified in five of our specimens (71%). The coronal plane provided the best evaluation. The peroneus longus tendon changes its direction at three points then obliquely crosses the sole and inserts in the base of the first metatarsal bone and the plantar aspect of the first cuneiform. MR imaging provides detailed information about the anatomy of tendons in the plantar aspect of the ankle and foot. It allows analysis of their insertions and the intertendinous connection between the flexor hallucis longus and the flexor digitorum longus tendons. (orig.)

  13. [Isokinetic assessment with two years follow-up of anterior cruciate ligament reconstruction with patellar tendon or hamstring tendons].

    Science.gov (United States)

    Condouret, J; Cohn, J; Ferret, J-M; Lemonsu, A; Vasconcelos, W; Dejour, D; Potel, J-F

    2008-12-01

    This retrospective multicentric study was designed to assess the outcome of quadriceps and hamstrings muscles two years after Anterior Cruciate Ligament (ACL) reconstruction and compare muscles recovery depending on the type of graft and individual variables like age, gender, level of sport, but also in terms of discomfort, pain and functional score. The results focused on the subjective and objective IKDC scores, SF36, the existence or not of subjective disorders and their location. The review included isokinetic muscle tests concentric and eccentric extensors/flexors but also internal rotators/external rotators with analysis of mean work and mean power. One hundred and twenty-seven patients were included with an average age 29 years (+/-10). They all had an ACL reconstruction with patellar tendon or hamstring tendon with single or double bundles. In the serie, the average muscles deficit at two years was 10% for the flexors and extensors but with a significant dispersion. Significant differences were not noted in the mean values of all parameters in term of sex or age (over 30 years or not), neither the type of sport, nor of clinical assessment (Class A and B of objective IKDC score), nor the existence of anterior knee pain. There was a relationship between the level of extensor or flexor recovery and the quality of functional results with minimal muscle deficits close to 5% if the IKDC score was over 90 and deficits falling to 15% in the group with IKDC score less than 90. The type of reconstruction (patellar tendon versus hamstrings) had an influence on the muscle deficit. For extensors, the recovery was the same in the two groups, more than 90% at two years and the distribution of these two populations by level of deficit was quite the same. For flexors, residual deficits were significantly higher in the hamstrings group on the three studied parameters whatever the speed and the type of contraction (concentric or eccentric) with an average deficit of 14 to 18

  14. The simple transverse intraosseous phalangeal suture for zone 1 flexor digitorum profundus injuries: case series and review of the literature.

    Science.gov (United States)

    Markeson, Daniel Benjamin; Evgeniou, Evgenios; Choa, Robert; Iyer, Srinivasan

    2013-05-01

    Zone 1 flexor digitorum profundus injury often precludes the use of a simple core suture as a result of a distal remnant that is too short. The aim of this study was to assess the senior author's (S.I.) simple technique for reinsertion of the flexor digitorum profundus tendon. The case series consisted of 12 patients who required a primary flexor digitorum profundus repair in zone 1, with all repairs performed by the senior author. A Bruner incision was extended to the pulp to expose the base of the distal phalanx. A two-strand repair was anchored to the distal phalanx using the author's technique, which involved passing a 3-0 polypropylene suture on a straight needle through a hypodermic needle that had been drilled through the base of the distal phalanx. This provided a stable, intraosseous, internal repair, allowing a standard early active mobilization regimen. Two patients had excellent results and 10 had good results in terms of distal interphalangeal joint range of movement (mean, 57 degrees; range, 51 to 80 degrees) and Quick Disabilities of the Arm, Shoulder and Hand questionnaire scores (mean, 12; range, 0 to 31.8). There were no reported tendon ruptures at the time of writing this article (range, 6 to 37 months after surgery). The authors present a technique for the repair of zone 1 flexor digitorum profundus injuries that is simple, can be performed quickly, is easily learned, and has results that compare favorably with other techniques in the literature. Furthermore, there is limited morbidity to surrounding fingertip structures. Therapeutic, IV.

  15. Effects of smartphone overuse on hand function, pinch strength, and the median nerve.

    Science.gov (United States)

    İnal, Esra Erkol; Demİrcİ, kadİr; Çetİntürk, Azİze; Akgönül, Mehmet; Savaş, Serpİl

    2015-08-01

    In this study we investigated the flexor pollicis longus (FPL) tendon and median nerve in smartphone users by ultrasonography to assess the effects of smartphone addiction on the clinical and functional status of the hands. One hundred two students were divided into 3 groups: non-users, and high or low smartphone users. Smartphone Addiction Scale (SAS) scores and grip and pinch strengths were recorded. Pain in thumb movement and rest and hand function were evaluated on the visual analog scale (VAS) and the Duruöz Hand Index (DHI), respectively. The cross-sectional areas (CSAs) of the median nerve and the FPL tendon were calculated bilaterally using ultrasonography. Significantly higher median nerve CSAs were observed in the dominant hands of the high smartphone users than in the non-dominant hands (PSmartphone overuse enlarges the median nerve, causes pain in the thumb, and decreases pinch strength and hand functions. © 2015 Wiley Periodicals, Inc.

  16. Effects of in vivo applications of peripheral blood-derived mesenchymal stromal cells (PB-MSCs) and platlet-rich plasma (PRP) on experimentally injured deep digital flexor tendons of sheep.

    Science.gov (United States)

    Martinello, Tiziana; Bronzini, Ilaria; Perazzi, Anna; Testoni, Stefania; De Benedictis, Gulia Maria; Negro, Alessandro; Caporale, Giovanni; Mascarello, Francesco; Iacopetti, Ilaria; Patruno, Marco

    2013-02-01

    Tendon injuries, degenerative tendinopathies, and overuse tendinitis are common in races horses. Novel therapies aim to restore tendon functionality by means of cell-based therapy, growth factor delivery, and tissue engineering approaches. This study examined the use of autologous mesenchymal stromal cells derived from peripheral blood (PB-MSCs), platelet-rich plasma (PRP) and a combination of both for ameliorating experimental lesions on deep digital flexor tendons (DDFT) of Bergamasca sheep. In particular, testing the combination of blood-derived MSCs and PRP in an experimental animal model represents one of the few studies exploring a putative synergistic action of these treatments. Effectiveness of treatments was evaluated at 30 and 120 days comparing clinical, ultrasonographic, and histological features together with immunohistochemical expression of collagen types 1 and 3, and cartilage oligomeric matrix protein (COMP). Significant differences were found between treated groups and their corresponding controls (placebo) regarding tendon morphology and extracellular matrix (ECM) composition. However, our results indicate that the combined use of PRP and MSCs did not produce an additive or synergistic regenerative response and highlighted the predominant effect of MSCs on tendon healing, enhanced tissue remodeling and improved structural organization. Copyright © 2012 Orthopaedic Research Society.

  17. Effects of 12-wk eccentric calf muscle training on muscle-tendon glucose uptake and SEMG in patients with chronic Achilles tendon pain

    DEFF Research Database (Denmark)

    Masood, Tahir; Kalliokoski, Kari; Magnusson, S Peter

    2014-01-01

    High-load eccentric exercises have been a key component in the conservative management of chronic Achilles tendinopathy. This study investigated the effects of a 12-wk progressive, home-based eccentric rehabilitation program on ankle plantar flexors' glucose uptake (GU) and myoelectric activity......, while the asymptomatic leg displayed higher uptake for medial gastrocnemius and flexor hallucis longus (P tendon GU than the controls (P effect on the tendon GU. Concerning SEMG, at baseline, soleus showed more relative...... within- or between-group differences. Eccentric rehabilitation was effective in decreasing subjective severity of Achilles tendinopathy. It also resulted in redistribution of relative electrical activity, but not metabolic activity, within the triceps surae muscle....

  18. Effects of 12-wk eccentric calf muscle training on muscle-tendon glucose uptake and SEMG in patients with chronic Achilles tendon pain.

    Science.gov (United States)

    Masood, Tahir; Kalliokoski, Kari; Magnusson, S Peter; Bojsen-Møller, Jens; Finni, Taija

    2014-07-15

    High-load eccentric exercises have been a key component in the conservative management of chronic Achilles tendinopathy. This study investigated the effects of a 12-wk progressive, home-based eccentric rehabilitation program on ankle plantar flexors' glucose uptake (GU) and myoelectric activity and Achilles tendon GU. A longitudinal study design with control (n = 10) and patient (n = 10) groups was used. Surface electromyography (SEMG) from four ankle plantar flexors and GU from the same muscles and the Achilles tendon were measured during submaximal intermittent isometric plantar flexion task. The results indicated that the symptomatic leg was weaker (P eccentric rehabilitation. Additionally, the rehabilitation resulted in greater GU in both soleus (P tendon GU than the controls (P effect on the tendon GU. Concerning SEMG, at baseline, soleus showed more relative activity in the symptomatic leg compared with both the asymptomatic and control legs (P Eccentric rehabilitation was effective in decreasing subjective severity of Achilles tendinopathy. It also resulted in redistribution of relative electrical activity, but not metabolic activity, within the triceps surae muscle. Copyright © 2014 the American Physiological Society.

  19. Knee extension and flexion muscle power after anterior cruciate ligament reconstruction with patellar tendon graft or hamstring tendons graft: a cross-sectional comparison 3 years post surgery

    DEFF Research Database (Denmark)

    Ageberg, Eva; Roos, Harald; Silbernagel, Karin

    2008-01-01

    Hamstring muscles play a major role in knee-joint stabilization after anterior cruciate ligament (ACL) injury. Weakness of the knee extensors after ACL reconstruction with patellar tendon (PT) graft, and in the knee flexors after reconstruction with hamstring tendons (HT) graft has been observed ...

  20. Tendon Transfer Surgery

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is ... Hand Therapist? Media Find a Hand Surgeon Home Anatomy ... DESCRIPTION The tendon is the strong cord at either end of a muscle that is attached to bone. Tendons , combined with ...

  1. Study of recurrent branch of median nerve (Thenar's muscular branch in relation to the flexor retinaculum and median in 64 hands (32 Men

    Directory of Open Access Journals (Sweden)

    Amirsadri R

    1998-07-01

    Full Text Available Variation of recurred branch of median nerve in relation to the median and flexor retinaculum are significant for both hand surgeons and specialists always. In this study, 64 cadaver hands (32 men have been dissected. The median nerve was identified at the proximal edge of the flexor retinaculum, and in order to expose carpal tunnel the ligament was divided, and the above subjects were studied. The results are: 1 The relation of recurrent nerve to the flexor retinaculum was classified into 4 types: A In (53.1% of subjects, this branch arises from the median after the flexor retinaculum. B In (31.3% of subjects, it arises from the median in the carpal tunnel and the moves around the lower edge of flexor retinaculum and enters the thenar region. C In (14.1% of subjects, it arises from the median in the carpal tunnel and pierces the flexor retinaculum. D In (1.56% of subjects it arises, in the carpal tunnel and it divides into two subbranches here. One follows pattern A and the other pattern C. 2 In this step, the relation of the recurrent branch to the median nerve was studied. The results show that inspite of this image even though most often the recurrent branch arises from the lateral side of median, in (68.75% of subjects it arises from it's anterior surface. The MC Nemar test reveals that there is no relation between manifestation of mentioned patterns with right or left hands.

  2. Clinical and morphological evaluation of snake venom derived fibrin glue on the tendon healing in dogs

    Directory of Open Access Journals (Sweden)

    G. C. Ferraro

    2005-12-01

    Full Text Available The aim of this study was to evaluate the effect of snake venom derived fibrin glue on the healing of the deep digital flexor tendon, during three periods. The tendon of the 2nd digit of 30 thoracic limbs of dogs was partially sectioned for glue application. Biopsies were performed 7, 15, and 30 days post surgery for the clinical and morphological study of tendons. Analysis of the results showed that 73.3% of the tendons showed stump retraction and 16.6% moderate to excessive adherence, which affected sliding. There was a significant difference in the number of inflammatory cells among the three studied periods, being the highest on day 15. The morphological analysis revealed a typical tendon healing process with a lower level of inflammation in the acute phase, facilitating the cicatricial maturation phase. Snake venom derived fibrin glue promotes the healing in dog flexor tendon.

  3. Design and Development of Effective Transmission Mechanisms on a Tendon Driven Hand Orthosis for Stroke Patients

    OpenAIRE

    Park, Sangwoo; Weber, Lynne; Bishop, Lauri; Stein, Joel; Ciocarlie, Matei

    2018-01-01

    Tendon-driven hand orthoses have advantages over exoskeletons with respect to wearability and safety because of their low-profile design and ability to fit a range of patients without requiring custom joint alignment. However, no existing study on a wearable tendon-driven hand orthosis for stroke patients presents evidence that such devices can overcome spasticity given repeated use and fatigue, or discusses transmission efficiency. In this study, we propose two designs that provide effective...

  4. Effect of Tendon Vibration on Hemiparetic Arm Stability in Unstable Workspaces.

    Directory of Open Access Journals (Sweden)

    Megan O Conrad

    Full Text Available Sensory stimulation of wrist musculature can enhance stability in the proximal arm and may be a useful therapy aimed at improving arm control post-stroke. Specifically, our prior research indicates tendon vibration can enhance stability during point-to-point arm movements and in tracking tasks. The goal of the present study was to investigate the influence of forearm tendon vibration on endpoint stability, measured at the hand, immediately following forward arm movements in an unstable environment. Both proximal and distal workspaces were tested. Ten hemiparetic stroke subjects and 5 healthy controls made forward arm movements while grasping the handle of a two-joint robotic arm. At the end of each movement, the robot applied destabilizing forces. During some trials, 70 Hz vibration was applied to the forearm flexor muscle tendons. 70 Hz was used as the stimulus frequency as it lies within the range of optimal frequencies that activate the muscle spindles at the highest response rate. Endpoint position, velocity, muscle activity and grip force data were compared before, during and after vibration. Stability at the endpoint was quantified as the magnitude of oscillation about the target position, calculated from the power of the tangential velocity data. Prior to vibration, subjects produced unstable, oscillating hand movements about the target location due to the applied force field. Stability increased during vibration, as evidenced by decreased oscillation in hand tangential velocity.

  5. Frontal plane fractures of the accessory carpal bone and implications for the carpal sheath of the digital flexor tendons.

    Science.gov (United States)

    Minshall, G J; Wright, I M

    2014-09-01

    Accurate radiological and ultrasonographic descriptions of frontal plane fractures of the accessory carpal bone (ACB) are lacking, and implications of these fractures for the carpal sheath and its contents have not previously been reported. Aims were as follows: 1) to describe the location and radiological features of frontal plane fractures of the ACB; 2) to document communication of displaced fractures with the carpal sheath and consequent injury to the deep digital flexor tendon (DDFT); 3) to describe ultrasonographic identification of lesions; and 4) to report tenoscopic evaluation and treatment. Retrospective case series. Analysis of frontal plane fractures of the ACB referred to a single hospital between 2006 and 2012, including review of radiographic, ultrasonographic and tenoscopic images. Nine fractures were identified, of which 8 displaced fractures all communicated with the carpal sheath. Comminuted fragments and/or protruding fracture margins lacerated the lateral margin of the enclosed DDFT. This was identifiable ultrasonographically and confirmed at tenoscopy in 7 cases. Treatment in these horses consisted of removal of torn tendon tissue together with fragmentation and protuberant fracture edges, and 7 of 7 cases returned to work. One horse with a nondisplaced fracture was managed with immobilisation; the fracture healed, and the horse returned to work. One horse with a displaced fracture was retired to stud. Frontal plane fractures of the ACB occur palmar to the groove in its lateral margin for the tendon of insertion of ulnaris lateralis. Comminuted fragments can displace distally within the carpal sheath to a mid-metacarpal level or abaxially to lie extrathecally, lateral to the parent bone. Displaced fractures communicate with the carpal sheath and traumatise the DDFT. © 2013 EVJ Ltd.

  6. FLEXOR TENDON REPAIR IN THE HAND

    African Journals Online (AJOL)

    Method of Repair. Cases. AGE, SEX ... method is at fault and not the dexterity of the operator or his technique. .... Physio- therapy seldom makes stiff fingers work, but it prevents .... or repaired later by direct suture, graft or transplant. No. of.

  7. Kinesthetic perception based on integration of motor imagery and afferent inputs from antagonistic muscles with tendon vibration.

    Science.gov (United States)

    Shibata, E; Kaneko, F

    2013-04-29

    The perceptual integration of afferent inputs from two antagonistic muscles, or the perceptual integration of afferent input and motor imagery are related to the generation of a kinesthetic sensation. However, it has not been clarified how, or indeed whether, a kinesthetic perception would be generated by motor imagery if afferent inputs from two antagonistic muscles were simultaneously induced by tendon vibration. The purpose of this study was to investigate how a kinesthetic perception would be generated by motor imagery during co-vibration of the two antagonistic muscles at the same frequency. Healthy subjects participated in this experiment. Illusory movement was evoked by tendon vibration. Next, the subjects imaged wrist flexion movement simultaneously with tendon vibration. Wrist flexor and extensor muscles were vibrated according to 4 patterns such that the difference between the two vibration frequencies was zero. After each trial, the perceived movement sensations were quantified on the basis of the velocity and direction of the ipsilateral hand-tracking movements. When the difference in frequency applied to the wrist flexor and the extensor was 0Hz, no subjects perceived movements without motor imagery. However, during motor imagery, the flexion velocity of the perceived movement was higher than the flexion velocity without motor imagery. This study clarified that the afferent inputs from the muscle spindle interact with motor imagery, to evoke a kinesthetic perception, even when the difference in frequency applied to the wrist flexor and extensor was 0Hz. Furthermore, the kinesthetic perception resulting from integrations of vibration and motor imagery increased depending on the vibration frequency to the two antagonistic muscles. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  8. MRI of the hand and wrist joint of climbers. Imaging of lesions and overstrain injury. Die MRT von Hand und Handgelenk bei Sportkletterern. Darstellung von Verletzungen und Ueberlastungsfolgen

    Energy Technology Data Exchange (ETDEWEB)

    Heuck, A. (Technische Univ. Muenchen (Germany). Inst. und Poliklinik fuer Strahlentherapie und Radiologische Onkologie); Hochholzer, T.; Keinath, C. (Technische Univ. Muenchen (Germany). Klinik und Poliklinik fuer Sportverletzungen)

    1992-05-01

    The hands and wrists of 20 top-level rock climbers with sports injuries and overstress abnormalities were compared with the hands and wrists of 10 normal volunteers. They were all studied with MR imaging at 1.5 T. The imaging protocol included spin-echo and gradient-echo sequences with 1- to 5-mm-thick contiguous slices in the axial, coronal and/or sagittal planes, depending on the location and nature of the suspected injury. Typical hand and wrist lesions depicted with MRI in climbers consisted of annular ligament tears, lesions of the flexor tendons, tenosynovitis, ganglion cysts, joint effusion and functional carpal tunnel syndrome. The MRI findings on these abnormalities were compared to normal findings and those with ultrasound and plain films. In addition, hypertrophic changes in the muscles, tendons, ligaments, and bones of top-level rock climbers were assessed morphometrically. MRI proved to be the superior imaging modality in the diagnosis of sports injuries and overstress abnormalities of the hand the wrist in rock-climbing athletes. (orig.).

  9. Aging contributes to inflammation in upper extremity tendons and declines in forelimb agility in a rat model of upper extremity overuse.

    Directory of Open Access Journals (Sweden)

    David M Kietrys

    Full Text Available We sought to determine if tendon inflammatory and histopathological responses increase in aged rats compared to young rats performing a voluntary upper extremity repetitive task, and if these changes are associated with motor declines. Ninety-six female Sprague-Dawley rats were used in the rat model of upper extremity overuse: 67 aged and 29 young adult rats. After a training period of 4 weeks, task rats performed a voluntary high repetition low force (HRLF handle-pulling task for 2 hrs/day, 3 days/wk for up to 12 weeks. Upper extremity motor function was assessed, as were inflammatory and histomorphological changes in flexor digitorum and supraspinatus tendons. The percentage of successful reaches improved in young adult HRLF rats, but not in aged HRLF rats. Forelimb agility decreased transiently in young adult HRLF rats, but persistently in aged HRLF rats. HRLF task performance for 12 weeks lead to increased IL-1beta and IL-6 in flexor digitorum tendons of aged HRLF rats, compared to aged normal control (NC as well as young adult HRLF rats. In contrast, TNF-alpha increased more in flexor digitorum tendons of young adult 12-week HRLF rats than in aged HRLF rats. Vascularity and collagen fibril organization were not affected by task performance in flexor digitorum tendons of either age group, although cellularity increased in both. By week 12 of HRLF task performance, vascularity and cellularity increased in the supraspinatus tendons of only aged rats. The increased cellularity was due to increased macrophages and connective tissue growth factor (CTGF-immunoreactive fibroblasts in the peritendon. In conclusion, aged rat tendons were overall more affected by the HRLF task than young adult tendons, particularly supraspinatus tendons. Greater inflammatory changes in aged HRLF rat tendons were observed, increases associated temporally with decreased forelimb agility and lack of improvement in task success.

  10. Extensor Tendon Injuries

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is a Hand Surgeon? What is a Hand Therapist? Media Find a Hand Surgeon Home Anatomy Extensor Tendon Injuries Email to a friend * required ...

  11. Bilateral congenital absence of flexor pollicis longus with thumb hypoplasia and thenar atrophy

    International Nuclear Information System (INIS)

    Chaudhary, Vikas; Sehgal, Harsha; Bano, Shahina; Parmar, Pranjali R; Kumar, Sanjay

    2014-01-01

    Congenital absence of flexor pollicis longus with or without associated anomalies of thenar muscles and thumb is of rare occurrence. Inability to flex the interphalangeal joint of the thumb and absent dorsal wrinkles and flexion creases of the thumb are important clues to the diagnosis. Routine radiography and cross-sectional imaging help to confirm and document the condition. This article presents an extremely rare case of bilateral congenital absence of flexor pollicis longus tendon with thumb hypoplasia and thenar atrophy

  12. The use of ionising radiation for the treatment of injuries to flexor tendons and supporting ligaments in horses

    International Nuclear Information System (INIS)

    Franks, P.W.

    1979-01-01

    A technique was developed using radioactive isotopes as a source of radiation for the treatment of injuries to the superficial and deep flexor tendons and the associated ligaments in the horse. The treatment area was sub-divided so that different dosages could be applied over the limb as necessary. A plaster of Paris impression was taken on the whole area to be treated. In the isotope laboratory a plaster negative was made and loaded with the dose of radioactive isotope. The loaded cast was then strapped to the horse's limb for the calculated time, usually about three days. A total of 42 horses were treated and follow up information was obtained from 28. Twenty-five animals raced again: two relapsed before racing and one was destroyed with navicular disease. Ten of the 42 horses had been treated by firing before irradiation. Five of these returned to racing but the history of four of them was not known. (author)

  13. Sonography of pathological changes in the hand

    Directory of Open Access Journals (Sweden)

    Anna Dębek

    2014-03-01

    Full Text Available Everyday medical practice shows that most common problems within the hand result from overload, injuries and degeneration. Dorsal side pathologies such as de Quervain’s and Wartenberg’s disease, intersection syndrome or degenerative lesions of carpometacarpal joint of the thumb discussed in the paper can be accurately diagnosed and differentiated by means of ultrasound examination. Ultrasound is similarly powerful in detection and grading of traumatic lesions involving extensor tendons and their sagittal bands or the flexor tendons and their pulleys. In the case of carpal tunnel syndrome one can not only visualize the median nerve but also other structures of the tunnel that may cause compression. Similarly ulnar nerve compression within the Guyon’s canal can be well evaluated. In cases of nerve trauma one can precisely define the level, and in cases of nerve discontinuity, the distance between stumps can be measured which is important in surgery planning. Often nerve trauma is a sequelae of tendon reconstruction. In such cases scars and nerve entrapment can be depicted. Tumors within a hand are usually benign, of which the most common are ganglia. On ultrasound examination a connection between a ganglion and its source (usually a joint or sheath can frequently be defined. The relationship of tumors to nerves, tendon sheaths or vessels may suggest their nature. Ultrasound with dynamic tissue assessment is a very valuable adjunct to clinical examination.

  14. Flexor origin slide for contracture of spastic finger flexor muscles: a retrospective study.

    Science.gov (United States)

    Thevenin-Lemoine, Camille; Denormandie, Philippe; Schnitzler, Alexis; Lautridou, Christine; Allieu, Yves; Genêt, François

    2013-03-06

    Contracture of the wrist and extrinsic finger flexor and pronator muscles is a common consequence of central nervous system disorders. The proximal release of the extrinsic flexor and pronator muscles was first described by Page and Scaglietti for a Volkmann contracture. The aim of the present study was to assess the amount of increase in extension and the improvements in global hand function that can be expected following this lengthening procedure in patients with central nervous system disorders. A single-center retrospective review of patients with central nervous system lesions and contractures of the wrist and extrinsic finger flexor and forearm pronator muscles, causing aesthetic, hygienic, or functional impairment, was carried out. The Page-Scaglietti technique was used for all interventions. Before the operation, motor nerve blocks were used to distinguish between spasticity and contractures with surgical intervention only for contractures. The Zancolli and House classifications were used to evaluate improvements. Data from fifty-four hands and fifty patients (thirty-five men and fifteen women) were evaluated. The mean duration of follow-up (and standard deviation) was 26 ± 21 months (range, three to 124 months). The mean gain (and standard deviation) in wrist extension with fingers extended was 67° ± 25° (range, -10° to 110°). Preoperatively, no hands were classified as Zancolli Group 1, whereas twenty-five hands were classified as Zancolli Group 1 at the latest follow-up review. Ten nonfunctional hands (rated as House Group 0 or Group 1) became functional as a supporting hand postoperatively. Zancolli and House classifications increased significantly (p contracture of the intrinsic muscles, which required further intervention. The Page-Scaglietti technique appears to improve range of motion and function in people with wrist and finger contractures due to central nervous system disorders.

  15. Corticospinal excitability changes following prolonged muscle tendon vibration

    NARCIS (Netherlands)

    Steyvers, M.; Levin, O.; Baelen, M.G.M. van; Swinnen, S.P.

    2003-01-01

    The present experiment addressed the time course of corticospinal excitability changes following interventional muscle tendon vibration. Using transcranial magnetic stimulation, motor evoked potentials of the flexor carpi radialis and extensor carpi radialis brevis muscle were recorded for a period

  16. Compact and low-cost humanoid hand powered by nylon artificial muscles.

    Science.gov (United States)

    Wu, Lianjun; Jung de Andrade, Monica; Saharan, Lokesh Kumar; Rome, Richard Steven; Baughman, Ray H; Tadesse, Yonas

    2017-02-03

    This paper focuses on design, fabrication and characterization of a biomimetic, compact, low-cost and lightweight 3D printed humanoid hand (TCP Hand) that is actuated by twisted and coiled polymeric (TCP) artificial muscles. The TCP muscles were recently introduced and provided unprecedented strain, mechanical work, and lifecycle (Haines et al 2014 Science 343 868-72). The five-fingered humanoid hand is under-actuated and has 16 degrees of freedom (DOF) in total (15 for fingers and 1 at the palm). In the under-actuated hand designs, a single actuator provides coupled motions at the phalanges of each finger. Two different designs are presented along with the essential elements consisting of actuators, springs, tendons and guide systems. Experiments were conducted to investigate the performance of the TCP muscles in response to the power input (power magnitude, type of wave form such as pulsed or square wave, and pulse duration) and the resulting actuation stroke and force generation. A kinematic model of the flexor tendons was developed to simulate the flexion motion and compare with experimental results. For fast finger movements, short high-power pulses were employed. Finally, we demonstrated the grasping of various objects using the humanoid TCP hand showing an array of functions similar to a natural hand.

  17. Investigation Of Wrist Flexor/Extensor Muscle Strength Following Arthroscopic Surgical Treatment Of Lateral Epicondylitis

    Directory of Open Access Journals (Sweden)

    Mustafa Onur SERBEST

    2016-03-01

    Full Text Available Objective: Lateral epicondylitis is a common disease of elbow joint. Repetitive wrist activities and activities that requires strength are risk factors. Wrist extensor muscle strength are decreased in patients with lateral epicondylitis. Materials and Methods: Eight patients with a diagnosis of lateral epicondylitis enrolled to study. Wrist flexor and extensor muscle strength of patients who were completed one year after surgery were measured by isokinetic dynamometer. Results: There were no statistically significant differences between the flexor and extensor muscle strength of the patients (p>0.05. Conclusion: In this study, arthroscopic extensor carpi radialis brevis tendon release in lateral epicondylitis has shown no negative effect on flexor and extensor wrist muscle stregth.

  18. MRI of the hand and wrist joint of climbers. Imaging of lesions and overstrain injury

    International Nuclear Information System (INIS)

    Heuck, A.; Hochholzer, T.; Keinath, C.

    1992-01-01

    The hands and wrists of 20 top-level rock climbers with sports injuries and overstress abnormalities were compared with the hands and wrists of 10 normal volunteers. They were all studied with MR imaging at 1.5 T. The imaging protocol included spin-echo and gradient-echo sequences with 1- to 5-mm-thick contiguous slices in the axial, coronal and/or sagittal planes, depending on the location and nature of the suspected injury. Typical hand and wrist lesions depicted with MRI in climbers consisted of annular ligament tears, lesions of the flexor tendons, tenosynovitis, ganglion cysts, joint effusion and functional carpal tunnel syndrome. The MRI findings on these abnormalities were compared to normal findings and those with ultrasound and plain films. In addition, hypertrophic changes in the muscles, tendons, ligaments, and bones of top-level rock climbers were assessed morphometrically. MRI proved to be the superior imaging modality in the diagnosis of sports injuries and overstress abnormalities of the hand the wrist in rock-climbing athletes. (orig.) [de

  19. Correction of severe postburn claw hand.

    Science.gov (United States)

    Davami, Babak; Pourkhameneh, Golnar

    2011-12-01

    Burn scar contractures are perhaps the most frequent and most frustrating sequelae of thermal injuries to the hand. Unfortunately, stiffness occurs in the burned hand quickly. A week of neglect in the burned hand can lead to digital malpositioning and distortion that may be difficult to correct. The dorsal contracture is the most common of all the complications of the burned hand. It is the result of damage to the thin dorsal skin and scant subcutaneous tissue, which offers little protection to the deeper structures. Consequently, these injuries are deep resulting in a spectrum of deformities that has remained the bane of reconstructive surgery. Flap coverage will be required in the event of exposure of joints and tendons with absent paratenons. Multiple different flap types are available to treat complex severe postburn hand contractures. In our center, which is the largest regional burn center in northwest Iran, we have considerable experience in the treatment of thermal hand injuries. Between 2005 and 2010, we treated 53 consecutive patients with 65 severe postburn hand deformities. There were 35 men and 18 women with a mean age of 35±3 years. Flame injury was the inciting traumatic event in each patient. The severity of original injury and inadequate early treatment resulted in all of the fingers developing a severe extension contracture with scarred and adherent extensor tendons and subluxed metacarpophalangeal joints. In 36 cases, the injury was in the patients' dominant hand. We first incised the dorsal aspect of the contracted hands where there was maximum tension, then tenolysed the extensor tendons and released the volar capsules, collateral ligaments, and volar plate in all cases. In 30 cases, we also tenolysed the flexor tendons. We reduced the subluxed metacarpophalangeal joints and fixed them with Kirschner wires in 70 to 90 degrees flexion. Then, we planned and performed axial groin flaps to reconstruct the defects in all of them. In all of these

  20. Two-stage reconstruction with the modified Paneva-Holevich technique.

    LENUS (Irish Health Repository)

    O'Shea, Kieran

    2013-05-01

    Flexor tendon reconstruction poses both a technical challenge to the hand surgeon and a rehabilitative challenge to the patient and therapist. The modified Paneva-Holevich technique, using a pedicled intra-synovial graft, is a safe and reliable means of staged flexor tendon reconstruction, offering a number of theoretical advantages over classic free-tendon grafting techniques. Clinical outcomes are at the least comparable, if not superior, to those achieved following free-tendon techniques with most authors reporting a low requirement for third stage tenolysis.

  1. Salvage Flexor Hallucis Longus Transfer for a Failed Achilles Repair: Endoscopic Technique.

    Science.gov (United States)

    Gonçalves, Sérgio; Caetano, Rubén; Corte-Real, Nuno

    2015-10-01

    Flexor hallucis longus (FHL) transfer is a well-established treatment option in failed Achilles tendon (AT) repair and has been routinely performed as an open procedure. We detail the surgical steps needed to perform an arthroscopic transfer of the FHL for a chronic AT rupture. The FHL tendon is harvested as it enters in its tunnel beneath the sustentaculum tali; a tunnel is then drilled in the calcaneus as near to the AT footprint as possible. By use of a suture-passing device, the free end of the FHL is advanced to the plantar aspect of the foot. After adequate tension is applied to the construct, the tendon is fixed in place with an interference screw in an inside-out fashion. This minimally invasive approach is a safe and valid alternative to classic open procedures with the obvious advantages of preserving the soft-tissue envelope and using a biologically intact tendon.

  2. Estudo comparativo entre as tenólises convencionais e com despertar intraoperatório realizadas na região do túnel osteofibroso flexor das mãos (zona 2 Comparative study between traditional tenolyses and with intraoperative awakening performed on the flexor osteofibrous tunnel region of the hands (zone 2

    Directory of Open Access Journals (Sweden)

    Tiago Guedes da Motta Mattar

    2009-01-01

    Full Text Available OBJETIVO: As tenólises dos tendões flexores na zona 2 são procedimentos difíceis e um verdadeiro desafio na cirurgia da mão. Com o objetivo de comparar os resultados obtidos entre as tenólises com despertar intraoperatório, realizadas sob anestesia locorregional (grupo 1, daqueles obtidos com as tenólises convencionais, realizadas sob anestesia geral ou bloqueio total do plexo braquial (grupo 2, os autores realizam um estudo prospectivo e controlado. MÉTODOS: Foram avaliados 22 pacientes com 39 dedos portadores de lesão de tendão flexor na zona 2 que evoluíram para aderências. Todos os pacientes foram operados após três meses e antes de um ano da sutura tendinosa primária. Todos apresentavam limitação da movimentação ativa sem melhora com a reabilitação. Os grupos 1 e 2 mostraram-se homogêneos em relação à idade dos pacientes, sexo, comprometimento pré-operatório e ausência de lesões ou patologias associadas. Todos os pacientes foram avaliados de acordo com a movimentação ativa (TAMs no período pré-operatório e com seis meses de pós-operatório. RESULTADOS: A análise estatística dos dados obtidos nos grupos 1 e 2 demonstra que as tenólises realizadas pelas duas técnicas proporcionam bons resultados. Ao comparar os resultados da movimentação ativa total após seis meses da tenólise, observa-se que os pacientes do grupo 1, tratados pela técnica do despertar intraoperatório, apresentavam melhores resultados. CONCLUSÕES: As tenólises dos flexores na zona 2 proporcionam bons resultados em termos de ganho de amplitude articular. A técnica de despertar intraoperatório com anestesia locorregional proporciona resultados mais satisfatórios que a técnica convencional.OBJECTIVE: Flexor tendon tenolysis on zone 2 is a difficult and really challenging for hand surgery. With the objective of comparing the results obtained between tenolyses with intraoperative awakening, performed with locoregional anesthesia

  3. Application of a novel Kalman filter based block matching method to ultrasound images for hand tendon displacement estimation.

    Science.gov (United States)

    Lai, Ting-Yu; Chen, Hsiao-I; Shih, Cho-Chiang; Kuo, Li-Chieh; Hsu, Hsiu-Yun; Huang, Chih-Chung

    2016-01-01

    Information about tendon displacement is important for allowing clinicians to not only quantify preoperative tendon injuries but also to identify any adhesive scaring between tendon and adjacent tissue. The Fisher-Tippett (FT) similarity measure has recently been shown to be more accurate than the Laplacian sum of absolute differences (SAD) and Gaussian sum of squared differences (SSD) similarity measures for tracking tendon displacement in ultrasound B-mode images. However, all of these similarity measures can easily be influenced by the quality of the ultrasound image, particularly its signal-to-noise ratio. Ultrasound images of injured hands are unfortunately often of poor quality due to the presence of adhesive scars. The present study investigated a novel Kalman-filter scheme for overcoming this problem. Three state-of-the-art tracking methods (FT, SAD, and SSD) were used to track the displacements of phantom and cadaver tendons, while FT was used to track human tendons. These three tracking methods were combined individually with the proposed Kalman-filter (K1) scheme and another Kalman-filter scheme used in a previous study to optimize the displacement trajectories of the phantom and cadaver tendons. The motion of the human extensor digitorum communis tendon was measured in the present study using the FT-K1 scheme. The experimental results indicated that SSD exhibited better accuracy in the phantom experiments, whereas FT exhibited better performance for tracking real tendon motion in the cadaver experiments. All three tracking methods were influenced by the signal-to-noise ratio of the images. On the other hand, the K1 scheme was able to optimize the tracking trajectory of displacement in all experiments, even from a location with a poor image quality. The human experimental data indicated that the normal tendons were displaced more than the injured tendons, and that the motion ability of the injured tendon was restored after appropriate rehabilitation

  4. [Severe course of a rare non-tuberculous Mycobacteriosis (M. haemophilum) of the hand - case report and strategic comments].

    Science.gov (United States)

    Schumacher, O; Dabernig, J; Nenadic, I; Ingianni, G; Cedidi, C

    2008-10-01

    Mycobacterium haemophilum belongs to the group of atypical mycobacteria and is rarely reported as a cause of upper extremity and hand infections. It is of low virulence. The bacterium seems to be ubiquitous. Sources and mechanism of infection are poorly defined. A 48-year-old female patient was admitted with chronic flexor tendon synovitis of the left palm and distal forearm site. Three debridements were carried out and wound swabs were taken. No proof of bacterial colonisation was found. Histologically a granulomatous infection with Langerhans cells was revealed. Effectively calculated monotherapy with ciprofloxacin was begun. Six weeks postoperatively Mycobacterium haemophilum was cultivated in a colaboration with the National Reference Centre for Mycobacteria in Borstel. Medication was changed to triple therapy with clarithromycin, ethambutol and rifabutin. The patient could carry out her daytime job three months postoperatively. One year after first admission functional impairment needed to be treated by scar excision and radical flexor tendon tendolysis. The palmar defect was resurfaced by using a transmetacarpal DMCA 2 flap at the same time. An almost full range of motion was achieved with intensive hand and physiotherapy after a total treatment period of 15 months. Patients with upper extremity infections caused by atypical Mycobacteria need qualified hand-surgical care. The decision about need and kind of medicamentous treatment is based on germ differentiation and should be made in cooperation with the National Reference Centre for Mycobacteria in Borstel. To shorten the diagnostic gap between first admission and detection of Mycobacteria in hand infections with a non-typical course of disease we suggest a standardised approach.

  5. A comparison of ultrasound and clinical examination in the detection of flexor tenosynovitis in early arthritis

    Directory of Open Access Journals (Sweden)

    Abouqal Redouane

    2011-05-01

    Full Text Available Abstract Background Tenosynovitis is widely accepted to be common in rheumatoid arthritis (RA and postulated to be the first manifestation of RA, but its true prevalence in early disease and in particular the hand has not been firmly established. The aims of this study were first to investigate the frequency and distribution of finger flexor tenosynovitis using ultrasound in early arthritis, second to compare clinical examination with ultrasound (US using the latter as the gold standard. Methods 33 consecutive patients who had who were initially diagnosed with polyarthritis and suspected of polyarthritis and clinical suspicion of inflammatory arthritis of the hands and wrists were assessed during consecutive, routine presentations to the rheumatology outpatient clinic. We scanned a total of 165 finger tendons and subsequent comparisons were made using clinical examination. Results Flexor tenosynovitis was found in 17 patients (51.5% on ultrasound compared with 16 (48.4% of all patients on clinical examination. Most commonly damaged joint involved on US was the second finger followed by the third, fifth, and fourth. Both modalities demonstrated more pathology on the second and third metacarpophalangeal (MCP compared with the fourth and fifth MCP. A joint-by-joint comparison of US and clinical examination demonstrated that although the sensitivity, specificities and positive predictive values of clinical examination were relatively high, negative predictive value of clinical examination was low (0.23. Conclusions Our study suggest that clinical examination can be a valuable tool for detecting flexor disease in view of its high specificity and positive predictive values, but a negative clinical examination does not exclude inflammation and an US should be considered. Further work is recommended to standardize definitions and image acquisition for peritendinous inflammation for ultrasound.

  6. Biomechanical effects of steroid injections used to treat pyogenic flexor tenosynovitis

    Directory of Open Access Journals (Sweden)

    Turvey Blake R

    2012-10-01

    Full Text Available Abstract Background A recent study from our laboratory has demonstrated improved range of motion in the toes of broiler chickens afflicted with pyogenic flexor tenosynovitis when treated with local antibiotic and corticosteroid injections, without surgical drainage. However, the use of corticosteroids as an adjunct treatment raised peer concern, as steroids are thought to have deleterious effects on tendon strength. The purpose of this study was to compare the tensile strength of the aforementioned steroid treated tendons, to a group of tendons administered with the current standard treatment: systemic antibiotics, surgical drainage and no corticosteroids. Methods Twenty-three tendons’ structural and material properties were investigated (fifteen receiving the standard treatment, eight receiving the steroid treatment. The measurements from each group were interpreted via Student’s unpaired t-test and a post-hoc power analysis. Results The steroid treated tendons did demonstrate a trend toward decreased mechanical properties when compared with the standard treatment group, but the results were not statistically significant. Conclusions Treatment of septic tenosynovitis with local corticosteroid and local antibiotic injections resulted in better digital motion, without a significant loss of tendon strength, over a twenty-eight day recovery period.

  7. Tendon shift in hallux valgus: observations at MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Eustace, S. [Department of Radiology, Boston University Medical Center Hospital, 88 East Newton Street, Atrium - 2, Boston, MA 02118 (United States); Williamson, D. [Department of Radiology, Brigham and Womens Hospital, Boston, Massachusetts (United States); Wilson, M. [Department of Orthopedics, Brigham and Womens Hospital, Boston, Massachusetts (United States); O`Byrne, J. [Department of Radiology, Boston University Medical Center Hospital, 88 East Newton Street, Atrium - 2, Boston, MA 02118 (United States); Bussolari, L. [Department of Radiology, Brigham and Womens Hospital, Boston, Massachusetts (United States); Thomas, M. [Department of Radiology, Brigham and Womens Hospital, Boston, Massachusetts (United States); Stephens, M. [Department of Radiology, Boston University Medical Center Hospital, 88 East Newton Street, Atrium - 2, Boston, MA 02118 (United States); Stack, J. [Department of Radiology, Boston University Medical Center Hospital, 88 East Newton Street, Atrium - 2, Boston, MA 02118 (United States); Weissman, B. [Department of Radiology, Brigham and Womens Hospital, Boston, Massachusetts (United States)

    1996-08-01

    Objective. This study was undertaken to demonstrate a shift in tendon alignment at the first metatarsophalangeal joint in patients with hallux valgus by means of magnetic resonance imaging. Design. Ten normal feet and 20 feet with the hallux valgus deformity conforming to conventional clinical and radiographic criteria were prospectively studied using magnetic resonance imaging. Correlation was made between tendon position at the first metatarsophalangeal joint and the severity of the hallux valgus deformity. Results. There is a significant shift in tendon position at the first metatarsophalangeal joint of patients with hallux valgus. The insertion of the abductor hallucis tendon is markedly plantarward and the flexor and extensor tendons bowstring at the first metatarsophalangeal joint compared with patients without the deformity. The severity of the tendon shift correlates with the hallux valgus angle and clinical severity of the hallux valgus deformity in each case. Conclusion. Patients with hallux valgus have a significant tendon shift at the first metatarsophalangeal joint which appears to contribute to development of the deformity. (orig.). With 4 figs., 1 tab.

  8. Tendon shift in hallux valgus: observations at MR imaging

    International Nuclear Information System (INIS)

    Eustace, S.; Williamson, D.; Wilson, M.; O'Byrne, J.; Bussolari, L.; Thomas, M.; Stephens, M.; Stack, J.; Weissman, B.

    1996-01-01

    Objective. This study was undertaken to demonstrate a shift in tendon alignment at the first metatarsophalangeal joint in patients with hallux valgus by means of magnetic resonance imaging. Design. Ten normal feet and 20 feet with the hallux valgus deformity conforming to conventional clinical and radiographic criteria were prospectively studied using magnetic resonance imaging. Correlation was made between tendon position at the first metatarsophalangeal joint and the severity of the hallux valgus deformity. Results. There is a significant shift in tendon position at the first metatarsophalangeal joint of patients with hallux valgus. The insertion of the abductor hallucis tendon is markedly plantarward and the flexor and extensor tendons bowstring at the first metatarsophalangeal joint compared with patients without the deformity. The severity of the tendon shift correlates with the hallux valgus angle and clinical severity of the hallux valgus deformity in each case. Conclusion. Patients with hallux valgus have a significant tendon shift at the first metatarsophalangeal joint which appears to contribute to development of the deformity. (orig.). With 4 figs., 1 tab

  9. Isolated flexor pollicis longus nerve fascicle lesion – a rare differential diagnosis of thumb flexion deficiency

    Directory of Open Access Journals (Sweden)

    Glauser, Eva

    2016-12-01

    Full Text Available A rare differential diagnosis of thumb flexion deficiency is an isolated flexor pollicis longus (FPL nerve fascicle lesion. We present a 42-year-old otherwise healthy female patient who developed a weak thumb-to-index pinch and deficient right thumb flexion following the removal of osteosynthesis plates after a forearm fracture. Clinically,the flexor pollicis longus function was absent, yet index flexion and sensibility were unimpaired. Tendon rupture was excluded using a tenodesis test and the electro-physiological result of isolated interosseus nerve fascicle lesion was confirmed intraoperatively by inspection and electrostimulation. Tendon transfer using the extensor carpi radialis longus reconstruct strong thumb flexion during pinch. In summary, due to its specific location and anatomy, the FPL branch is more prone to isolated neuropathy, e.g. by injections or operations, than to other fascicles of the anterior interosseus nerve. When confronted with sudden and isolated thumb flexion deficiency, specialists should be aware of this rare phenomenon.

  10. INDICATORS OF MAXIMAL FLEXOR FORCE OF LEFT AND RIGHT HAND FOR THE POLICE SELECTION CRITERIA PURPOSES

    Directory of Open Access Journals (Sweden)

    Milivoj Dopsaj

    2006-06-01

    Full Text Available As a part of their professional responsibilities, police officers have authorization, in situation determined by law, to apply physical force or means of force. Due to given professional reasons, selection among the candidates as well as routine physical capability assessments, should have professional-methodological basis and scientific foundation. Muscle groups of particular reference in relationship to estimate general contraction characteristic in regard to force, and at the same time very easy to test are flexor muscles of fingers of the hand (test “hand squeeze”. The aim of this research is to define criterion characteristic for the population to function for selection and estimation of the hand squeeze force among policemen. This research had 723 participants, students of the Police Academy, as representatives of policemen between 19 and 24 years of age. In order to estimate force of hand grip (both right and left hand, we utilized tensiometric method, and standard procedure previously described (1. For the statistical analysis we used basic descriptive analysis, cluster analysis (defining 7 characteristic classes (clusters as a function of population tested –unacceptable, poor, below average, averaged, above average, excellent and superior, and factor analysis (definition of the selection test as a function of selection procedure (10. Our results indicate that averaged hand grip force among the tested population is 61.70±8.97 DaN (Min – Max=43.43-101.41 for left hand, and 65.11±9.34 DaN (Min – Max= 46.54-109.75 for right hand. The values for the force of defined cluster centers of left hand are: Cluster1-7=50.22, 55.76, 61.61, 67.84, 74.71, 84.02 and 97.15 DaN, and right hand are: Cluster1-7=53.40, 60.27, 66.10, 72.20, 79.70, 92.55 and 105.65 DaNFactor analysis results have shown that one factor has been isolated that accounted for 91.10 worthy variance. Regarding the individual variability, for the saturation of the isolated

  11. Comparison of plantar flexor musculotendinous stiffness, geometry, and architecture in male runners with and without a history of tibial stress fracture.

    Science.gov (United States)

    Pamukoff, Derek N; Blackburn, J Troy

    2015-02-01

    Greater lower extremity joint stiffness may be related to the development of tibial stress fractures in runners. Musculotendinous stiffness is the largest contributor to joint stiffness, but it is unclear what factors contribute to musculotendinous stiffness. The purpose of this study was to compare plantar flexor musculotendinous stiffness, architecture, geometry, and Achilles tendon stiffness between male runners with and without a history of tibial stress fracture. Nineteen healthy runners (age = 21 ± 2.7 years; mass = 68.2 ± 9.3 kg; height = 177.3 ± 6.0 cm) and 19 runners with a history of tibial stress fracture (age = 21 ± 2.9 years; mass = 65.3 ± 6.0 kg; height = 177.2 ± 5.2 cm) were recruited from community running groups and the university's varsity and club cross-country teams. Plantar flexor musculotendinous stiffness was estimated from the damped frequency of oscillatory motion about the ankle follow perturbation. Ultrasound imaging was used to measure architecture and geometry of the medial gastrocnemius. Dependent variables were compared between groups via one-way ANOVAs. Previously injured runners had greater plantar flexor musculotendinous stiffness (P < .001), greater Achilles tendon stiffness (P = .004), and lesser Achilles tendon elongation (P = .003) during maximal isometric contraction compared with healthy runners. No differences were found in muscle thickness, pennation angle, or fascicle length.

  12. Hand trauma: A prospective observational study reporting diagnostic concordance in emergency hand trauma which supports centralised service improvements.

    Science.gov (United States)

    Miranda, B H; Spilsbury, Z P; Rosala-Hallas, A; Cerovac, S

    2016-10-01

    Hand injuries are common, contributing up to 30% of accident and emergency (A&E) attendances. The aim of this study was to prospectively analyse the pathological demographics of hand injuries in a level 1 trauma centre with a Hand Trauma Unit and direct A&E links, and compare clinical and intra-operative findings. The null hypothesis was that there would be no differences between clinical and intra-operative findings (100% diagnostic concordance). Data were prospectively collected for referrals during 2012. Referral diagnosis, additional pathologies found on clinical assessment and intra-operative findings were documented on a live database accessible from both the Hand Unit and associated operating theatres. Odds ratios were calculated using SAS. Injuries (1526) were identified in 1308 patients included in the study. Diagnostic concordance between Hand Unit clinical examination and intra-operative findings was 92.5% ± 2.85% (mean ± SEM); this was lower for flexor tendon injuries (56.3%) because a greater number of additional pathologies were found intra-operatively (2.25 ± 0.10). This 'trend' was noted across multiple referral pathologies including phalangeal fractures (1.28 ± 0.02; 82.9%), lacerations (1.33 ± 0.04; 79.1%), extensor tendon injuries (1.30 ± 0.05; 87.8%) and dislocations (1.18 ± 0.05; 87.8%). Odds ratio analysis indicated a relationship between primary referral diagnoses that were more or less likely to be associated with additional injuries (p management of hand trauma. Our findings, coupled with the presented relevant literature reports, lead us to advocate that A&E departments should move towards a system wherein links to specialist hand trauma services are in place; we hereby present useful data for hospitals implementing such services. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

  13. Tendon tissue engineering: Adipose 1 derived stem cell and GDF-5 mediated regeneration using electrospun matrix systems

    Science.gov (United States)

    James, R; Kumbar, S G; Laurencin, C T; Balian, G; Chhabra, A B

    2011-01-01

    Tendon tissue engineering with a biomaterial scaffold that mimics the tendon extracellular matrix (ECM) and is biomechanically suitable when combined with readily available autologous cells may provide successful regeneration of defects in tendon. Current repair strategies using suitable autografts and freeze-dried allografts lead to a slow repair process that is sub-optimal and fails to restore function, particularly in difficult clinical situations such as zone II flexor tendon injuries of the hand. We have investigated the effect of GDF-5 on cell proliferation and gene expression by primary rat adipose-derived stromal cells (ADSCs) that were cultured on poly(DL-lactide-co-glycolide) PLAGA fiber scaffold and compared to PLAGA 2D film scaffold. The electrospun scaffold mimics the collagen fiber bundles present in native tendon tissue, and supports the adhesion and proliferation of multipotent ADSCs. Gene expression of scleraxis, the neotendon marker was upregulated 7 – 8 fold at 1 week with GDF-5 treatment when cultured on 3D electrospun scaffold, and was significantly higher at 2 weeks compared to 2D films with or without GDF-5 treatment. Expression of the genes that encode the major tendon ECM protein, collagen type I, was increased by 4 fold starting at 1 week on treatment with 100ng/mL GDF-5, and at all time points the expression was significantly higher compared to 2D films irrespective of GDF-5 treatment. Thus stimulation with GDF-5 can modulate primary ADSCs on PLAGA fiber scaffold to produce a soft, collagenous musculoskeletal tissue that fulfills the need for tendon regeneration. PMID:21436509

  14. Hand Anatomy

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is ... Hand Therapist? Media Find a Hand Surgeon Home Anatomy Bones Joints Muscles Nerves Vessels Tendons Anatomy The upper extremity is ...

  15. Early sensory re-education of the hand after peripheral nerve repair based on mirror therapy: a randomized controlled trial

    Science.gov (United States)

    Paula, Mayara H.; Barbosa, Rafael I.; Marcolino, Alexandre M.; Elui, Valéria M. C.; Rosén, Birgitta; Fonseca, Marisa C. R.

    2016-01-01

    BACKGROUND: Mirror therapy has been used as an alternative stimulus to feed the somatosensory cortex in an attempt to preserve hand cortical representation with better functional results. OBJECTIVE: To analyze the short-term functional outcome of an early re-education program using mirror therapy compared to a late classic sensory program for hand nerve repair. METHOD: This is a randomized controlled trial. We assessed 20 patients with median and ulnar nerve and flexor tendon repair using the Rosen Score combined with the DASH questionnaire. The early phase group using mirror therapy began on the first postoperative week and lasted 5 months. The control group received classic sensory re-education when the protective sensation threshold was restored. All participants received a patient education booklet and were submitted to the modified Duran protocol for flexor tendon repair. The assessments were performed by the same investigator blinded to the allocated treatment. Mann-Whitney Test and Effect Size using Cohen's d score were used for inter-group comparisons at 3 and 6 months after intervention. RESULTS: The primary outcome (Rosen score) values for the Mirror Therapy group and classic therapy control group after 3 and 6 months were 1.68 (SD=0.5); 1.96 (SD=0.56) and 1.65 (SD=0.52); 1.51 (SD=0.62), respectively. No between-group differences were observed. CONCLUSION: Although some clinical improvement was observed, mirror therapy was not shown to be more effective than late sensory re-education in an intermediate phase of nerve repair in the hand. Replication is needed to confirm these findings. PMID:26786080

  16. Early sensory re-education of the hand after peripheral nerve repair based on mirror therapy: a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Mayara H. Paula

    2016-02-01

    Full Text Available BACKGROUND: Mirror therapy has been used as an alternative stimulus to feed the somatosensory cortex in an attempt to preserve hand cortical representation with better functional results. OBJECTIVE: To analyze the short-term functional outcome of an early re-education program using mirror therapy compared to a late classic sensory program for hand nerve repair. METHOD: This is a randomized controlled trial. We assessed 20 patients with median and ulnar nerve and flexor tendon repair using the Rosen Score combined with the DASH questionnaire. The early phase group using mirror therapy began on the first postoperative week and lasted 5 months. The control group received classic sensory re-education when the protective sensation threshold was restored. All participants received a patient education booklet and were submitted to the modified Duran protocol for flexor tendon repair. The assessments were performed by the same investigator blinded to the allocated treatment. Mann-Whitney Test and Effect Size using Cohen's d score were used for inter-group comparisons at 3 and 6 months after intervention. RESULTS: The primary outcome (Rosen score values for the Mirror Therapy group and classic therapy control group after 3 and 6 months were 1.68 (SD=0.5; 1.96 (SD=0.56 and 1.65 (SD=0.52; 1.51 (SD=0.62, respectively. No between-group differences were observed. CONCLUSION: Although some clinical improvement was observed, mirror therapy was not shown to be more effective than late sensory re-education in an intermediate phase of nerve repair in the hand. Replication is needed to confirm these findings.

  17. The interfascicular matrix enables fascicle sliding and recovery in tendon, and behaves more elastically in energy storing tendons.

    Science.gov (United States)

    Thorpe, Chavaunne T; Godinho, Marta S C; Riley, Graham P; Birch, Helen L; Clegg, Peter D; Screen, Hazel R C

    2015-12-01

    While the predominant function of all tendons is to transfer force from muscle to bone and position the limbs, some tendons additionally function as energy stores, reducing the cost of locomotion. Energy storing tendons experience extremely high strains and need to be able to recoil efficiently for maximum energy storage and return. In the equine forelimb, the energy storing superficial digital flexor tendon (SDFT) has much higher failure strains than the positional common digital extensor tendon (CDET). However, we have previously shown that this is not due to differences in the properties of the SDFT and CDET fascicles (the largest tendon subunits). Instead, there is a greater capacity for interfascicular sliding in the SDFT which facilitates the greater extensions in this particular tendon (Thorpe et al., 2012). In the current study, we exposed fascicles and interfascicular matrix (IFM) from the SDFT and CDET to cyclic loading followed by a test to failure. The results show that IFM mechanical behaviour is not a result of irreversible deformation, but the IFM is able to withstand cyclic loading, and is more elastic in the SDFT than in the CDET. We also assessed the effect of ageing on IFM properties, demonstrating that the IFM is less able to resist repetitive loading as it ages, becoming stiffer with increasing age in the SDFT. These results provide further indications that the IFM is important for efficient function in energy storing tendons, and age-related alterations to the IFM may compromise function and predispose older tendons to injury. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  18. Tendon tissue engineering: adipose-derived stem cell and GDF-5 mediated regeneration using electrospun matrix systems

    International Nuclear Information System (INIS)

    James, R; Kumbar, S G; Laurencin, C T; Balian, G; Chhabra, A B

    2011-01-01

    Tendon tissue engineering with a biomaterial scaffold that mimics the tendon extracellular matrix (ECM) and is biomechanically suitable, and when combined with readily available autologous cells, may provide successful regeneration of defects in tendon. Current repair strategies using suitable autografts and freeze-dried allografts lead to a slow repair process that is sub-optimal and fails to restore function, particularly in difficult clinical situations such as zone II flexor tendon injuries of the hand. We have investigated the effect of GDF-5 on cell proliferation and gene expression by primary rat adipose-derived stem cells (ADSCs) that were cultured on a poly(dl-lactide-co-glycolide) PLAGA fiber scaffold and compared to a PLAGA 2D film scaffold. The electrospun scaffold mimics the collagen fiber bundles present in native tendon tissue, and supports the adhesion and proliferation of multipotent ADSCs. Gene expression of scleraxis, the neotendon marker, was upregulated seven- to eightfold at 1 week with GDF-5 treatment when cultured on a 3D electrospun scaffold, and was significantly higher at 2 weeks compared to 2D films with or without GDF-5 treatment. Expression of the genes that encode the major tendon ECM protein, collagen type I, was increased by fourfold starting at 1 week on treatment with 100 ng mL -1 GDF-5, and at all time points the expression was significantly higher compared to 2D films irrespective of GDF-5 treatment. Thus stimulation with GDF-5 can modulate primary ADSCs on a PLAGA fiber scaffold to produce a soft, collagenous musculoskeletal tissue that fulfills the need for tendon regeneration.

  19. Tendon tissue engineering: adipose-derived stem cell and GDF-5 mediated regeneration using electrospun matrix systems.

    Science.gov (United States)

    James, R; Kumbar, S G; Laurencin, C T; Balian, G; Chhabra, A B

    2011-04-01

    Tendon tissue engineering with a biomaterial scaffold that mimics the tendon extracellular matrix (ECM) and is biomechanically suitable, and when combined with readily available autologous cells, may provide successful regeneration of defects in tendon. Current repair strategies using suitable autografts and freeze-dried allografts lead to a slow repair process that is sub-optimal and fails to restore function, particularly in difficult clinical situations such as zone II flexor tendon injuries of the hand. We have investigated the effect of GDF-5 on cell proliferation and gene expression by primary rat adipose-derived stem cells (ADSCs) that were cultured on a poly(DL-lactide-co-glycolide) PLAGA fiber scaffold and compared to a PLAGA 2D film scaffold. The electrospun scaffold mimics the collagen fiber bundles present in native tendon tissue, and supports the adhesion and proliferation of multipotent ADSCs. Gene expression of scleraxis, the neotendon marker, was upregulated seven- to eightfold at 1 week with GDF-5 treatment when cultured on a 3D electrospun scaffold, and was significantly higher at 2 weeks compared to 2D films with or without GDF-5 treatment. Expression of the genes that encode the major tendon ECM protein, collagen type I, was increased by fourfold starting at 1 week on treatment with 100 ng mL(-1) GDF-5, and at all time points the expression was significantly higher compared to 2D films irrespective of GDF-5 treatment. Thus stimulation with GDF-5 can modulate primary ADSCs on a PLAGA fiber scaffold to produce a soft, collagenous musculoskeletal tissue that fulfills the need for tendon regeneration.

  20. Tendon tissue engineering: adipose-derived stem cell and GDF-5 mediated regeneration using electrospun matrix systems

    Energy Technology Data Exchange (ETDEWEB)

    James, R [Department of Biomedical Engineering, University of Virginia, Charlottesville, VA 22908 (United States); Kumbar, S G; Laurencin, C T [Department of Orthopaedic Surgery, University of Connecticut Health Center, Farmington, CT 06030 (United States); Balian, G; Chhabra, A B, E-mail: ac2h@hscmail.mcc.virginia.edu [Department of Orthopaedic Surgery, University of Virginia, Charlottesville, VA 22908 (United States)

    2011-04-15

    Tendon tissue engineering with a biomaterial scaffold that mimics the tendon extracellular matrix (ECM) and is biomechanically suitable, and when combined with readily available autologous cells, may provide successful regeneration of defects in tendon. Current repair strategies using suitable autografts and freeze-dried allografts lead to a slow repair process that is sub-optimal and fails to restore function, particularly in difficult clinical situations such as zone II flexor tendon injuries of the hand. We have investigated the effect of GDF-5 on cell proliferation and gene expression by primary rat adipose-derived stem cells (ADSCs) that were cultured on a poly(dl-lactide-co-glycolide) PLAGA fiber scaffold and compared to a PLAGA 2D film scaffold. The electrospun scaffold mimics the collagen fiber bundles present in native tendon tissue, and supports the adhesion and proliferation of multipotent ADSCs. Gene expression of scleraxis, the neotendon marker, was upregulated seven- to eightfold at 1 week with GDF-5 treatment when cultured on a 3D electrospun scaffold, and was significantly higher at 2 weeks compared to 2D films with or without GDF-5 treatment. Expression of the genes that encode the major tendon ECM protein, collagen type I, was increased by fourfold starting at 1 week on treatment with 100 ng mL{sup -1} GDF-5, and at all time points the expression was significantly higher compared to 2D films irrespective of GDF-5 treatment. Thus stimulation with GDF-5 can modulate primary ADSCs on a PLAGA fiber scaffold to produce a soft, collagenous musculoskeletal tissue that fulfills the need for tendon regeneration.

  1. Changes in hip joint muscle-tendon lengths with mode of locomotion.

    Science.gov (United States)

    Riley, Patrick O; Franz, Jason; Dicharry, Jay; Kerrigan, D Casey

    2010-02-01

    We have reported that peak hip extension is nearly identical in walking and running, suggesting that anatomical constraints, such as flexor muscle tightness may limit the range of hip extension. To obtain a more mechanistic insight into mobility at the hip and pelvis we examined the lengths of the muscle-tendons units crossing the hip joint. Data defining the three-dimensional kinematics of 26 healthy runners at self-selected walking and running speeds were obtained. These data were used to scale and drive musculoskeletal models using OpenSIM. Muscle-tendon unit (MTU) lengths were calculated for the trailing limb illiacus, rectus femoris, gluteus maximus, and biceps femoris long head and the advancing limb biceps femoris and gluteus maximus. The magnitude and timing of MTU length peaks were each compared between walking and running. The peak length of the right (trailing limb) illiacus MTU, a pure hip flexor, was nearly identical between walking and running, while the maximum length of the rectus femoris MTU, a hip flexor and knee extensor, increased during running. The maximum length of the left (leading limb) biceps femoris was also unchanged between walking and running. Further, the timing of peak illiacus MTU length and peak contralateral biceps femoris MTU length occurred essentially simultaneously during running, at a time during gait when the hamstrings are most vulnerable to stretch injury. This latter finding suggests exploring the role for hip flexor stretching in combination with hamstring stretching to treat and/or prevent running related hamstring injury. Copyright 2009 Elsevier B.V. All rights reserved.

  2. Tendon synovial cells secrete fibronectin in vivo and in vitro

    International Nuclear Information System (INIS)

    Banes, A.J.; Link, G.W.; Bevin, A.G.; Peterson, H.D.; Gillespie, Y.; Bynum, D.; Watts, S.; Dahners, L.

    1988-01-01

    The chemistry and cell biology of the tendon have been largely overlooked due to the emphasis on collagen, the principle structural component of the tendon. The tendon must not only transmit the force of muscle contraction to bone to effect movement, but it must also glide simultaneously over extratendonous tissues. Fibronectin is classified as a cell attachment molecule that induces cell spreading and adhesion to substratum. The external surface of intact avian flexor tendon stained positively with antibody to cellular fibronectin. However, if the surface synovial cells were first removed with collagenase, no positive reaction with antifibronectin antibody was detected. Analysis of immunologically stained frozen sections of tendon also revealed fibronectin at the tendon synovium, but little was associated with cells internal in tendon. The staining pattern with isolated, cultured synovial cells and fibroblasts from the tendon interior substantiated the histological observations. Analysis of polyacrylamide gel profiles of 35 S-methionine-labeled proteins synthesized by synovial cells and internal fibroblasts indicated that fibronectin was synthesized principally by synovial cells. Fibronectin at the tendon surface may play a role in cell attachment to prevent cell removal by the friction of gliding. Alternatively, fibronectin, with its binding sites for hyaluronic acid and collagen, may act as a complex for boundary lubrication

  3. A study of the distribution of color Doppler flows in the superficial digital flexor tendon of young Thoroughbreds during their training periods.

    Science.gov (United States)

    Hatazoe, Takashi; Endo, Yoshiro; Iwamoto, Yohei; Korosue, Kenji; Kuroda, Taisuke; Inoue, Saemi; Murata, Daiki; Hobo, Seiji; Misumi, Kazuhiro

    2015-01-01

    Aim of this study was to evaluate the relationships of exercise and tendon injury with Doppler flows appearing in the superficial digital flexor tendon (SDFT) of young Thoroughbreds during training periods. The forelimb SDFTs of 24 one- to two-year-old Thoroughbreds clinically free of any orthopaedic disorders were evaluated using grey-scale (GS) and color Doppler (CD) images during two training periods between December 2013 to April 2015. Twelve horses per year were examined in December, February, and April in training periods that began in September and ended in April. The SDFT was evaluated in 3 longitudinal images of equal lengths (labelled 1, 2, 3 in order from proximal to distal), and 6 transversal images separated by equal lengths (labelled 1A, 1B, 2A, 2B, 3A and 3B in order from proximal to distal) of the metacarpus using both GS and CD. The running (canter and gallop) distance for 1 month before the date of the ultrasonographic examinations was increased in December, February, and April in both of the two training periods. CD flows defined as rhythmically blinking or pulsatory colored signals were found in 56 of 864 (6.4%) transversal CD images, in 28, 12, 13, and 3 images of 1A, 1B, 2A and 2B, respectively, and in 7, 14, and 35 images captured in December, February, and April, respectively. There were no longitudinal or transversal GS images indicating injury in the SDFTs in either of the two training periods. The increase of CD flows in the proximal regions of the SDFT are possibly related to the increase of the running distance during the training periods of the one- to two-year-old Thoroughbreds. Because no injury was diagnosed in the SDFTs by GS images during the training periods, the increase of CD flows in the proximal parts of SDFT is not necessarily predictive of tendon injury in the near future during the training period of young Thoroughbreds.

  4. Ultrasound of the elbow with emphasis on detailed assessment of ligaments, tendons, and nerves

    International Nuclear Information System (INIS)

    De Maeseneer, Michel; Brigido, Monica Kalume; Antic, Marijana; Lenchik, Leon; Milants, Annemieke; Vereecke, Evie; Jager, Tjeerd; Shahabpour, Maryam

    2015-01-01

    Highlights: •Medial and lateral tendons: the different muscles forming these tendons can be followed up to the insertion. The imaging anatomy is reviewed. •Medial and lateral ligaments: the anatomy is complex and specialized imaging planes and arm positions are necessary for accurate assessment. •Biceps tendon: the anatomy of the distal biceps and lacertus fibrosus are discussed and illustrated with cadaveric correlation. •US imaging of the nerves about the elbow and visualization of the possible compression points is discussed. -- Abstract: The high resolution and dynamic capability of ultrasound make it an excellent tool for assessment of superficial structures. The ligaments, tendons, and nerves about the elbow can be fully evaluated with ultrasound. The medial collateral ligament consists of an anterior and posterior band that can easily be identified. The lateral ligament complex consists of the radial collateral ligament, ulnar insertion of the annular ligament, and lateral ulnar collateral ligament, easily identified with specialized probe positioning. The lateral ulnar collateral ligament can best be seen in the cobra position. On ultrasound medial elbow tendons can be followed nearly up to their common insertion. The pronator teres, flexor carpi radialis, palmaris longus, and flexor digitorum superficialis can be identified. The laterally located brachioradialis and extensor carpi radialis longus insert on the supracondylar ridge. The other lateral tendons can be followed up to their common insertion on the lateral epicondyle. The extensor digitorum, extensor carpi radialis brevis, extensor digiti minimi, and extensor carpi ulnaris can be differentiated. The distal biceps tendon is commonly bifid. For a complete assessment of the distal biceps tendon specialized views are necessary. These include an anterior axial approach, medial and lateral approach, and cobra position. In the cubital tunnel the ulnar nerve is covered by the ligament of Osborne

  5. Ultrasound of the elbow with emphasis on detailed assessment of ligaments, tendons, and nerves

    Energy Technology Data Exchange (ETDEWEB)

    De Maeseneer, Michel, E-mail: Michel.demaeseneer@uzbrussel.be [Department of Radiology, Universitair Ziekenhuis Brussel, Brussels (Belgium); Brigido, Monica Kalume, E-mail: Mbrigido@med.umich.edu [Department of Radiology, University of Michigan, Ann Arbor, MI (United States); Antic, Marijana, E-mail: Misscroa@gmail.com [Department of Radiology, Universitair Ziekenhuis Brussel, Brussels (Belgium); Lenchik, Leon, E-mail: Llenchik@wakehealth.edu [Department of Radiology, Wake Forest University, Winston-Salem, NC (United States); Milants, Annemieke, E-mail: Annemieke.Milants@gmail.com [Department of Radiology, Universitair Ziekenhuis Brussel, Brussels (Belgium); Vereecke, Evie, E-mail: Evie.Vereecke@kuleuven-kulak.be [Department of Anatomy, KULAK, Katholieke Universiteit Leuven, Campus Kortrijk, Kortrijk (Belgium); Jager, Tjeerd [Aalsters Stedelijk Ziekenhuis, Aalst (Belgium); Shahabpour, Maryam, E-mail: Maryam.Shahabpour@uzbrussel.be [Department of Radiology, Universitair Ziekenhuis Brussel, Brussels (Belgium)

    2015-04-15

    Highlights: •Medial and lateral tendons: the different muscles forming these tendons can be followed up to the insertion. The imaging anatomy is reviewed. •Medial and lateral ligaments: the anatomy is complex and specialized imaging planes and arm positions are necessary for accurate assessment. •Biceps tendon: the anatomy of the distal biceps and lacertus fibrosus are discussed and illustrated with cadaveric correlation. •US imaging of the nerves about the elbow and visualization of the possible compression points is discussed. -- Abstract: The high resolution and dynamic capability of ultrasound make it an excellent tool for assessment of superficial structures. The ligaments, tendons, and nerves about the elbow can be fully evaluated with ultrasound. The medial collateral ligament consists of an anterior and posterior band that can easily be identified. The lateral ligament complex consists of the radial collateral ligament, ulnar insertion of the annular ligament, and lateral ulnar collateral ligament, easily identified with specialized probe positioning. The lateral ulnar collateral ligament can best be seen in the cobra position. On ultrasound medial elbow tendons can be followed nearly up to their common insertion. The pronator teres, flexor carpi radialis, palmaris longus, and flexor digitorum superficialis can be identified. The laterally located brachioradialis and extensor carpi radialis longus insert on the supracondylar ridge. The other lateral tendons can be followed up to their common insertion on the lateral epicondyle. The extensor digitorum, extensor carpi radialis brevis, extensor digiti minimi, and extensor carpi ulnaris can be differentiated. The distal biceps tendon is commonly bifid. For a complete assessment of the distal biceps tendon specialized views are necessary. These include an anterior axial approach, medial and lateral approach, and cobra position. In the cubital tunnel the ulnar nerve is covered by the ligament of Osborne

  6. Do not rush to return to sports after trigger finger injection.

    Science.gov (United States)

    Oh, Jeehae; Jo, Leechan; Lee, Jong In

    2015-04-01

    Trigger finger, or digital stenosing tenosynovitis, is a common hand problem. A widely accepted treatment is steroid injection into the flexor tendon sheath. This can cause rupture of the flexor tendon. However, to the best of our knowledge, there is no report on tendon rupture after a single corticosteroid injection. Moreover, there are no guidelines for patients with tendinopathy who want to return to sports after corticosteroid injection. Clinicians who perform local steroid injections for tendinopathy treatment should be aware of the possible dangers of tendon rupture and should confirm that steroids are not administrated into the tendon. Patients should also be warned about returning to sports prematurely and should be encouraged to gradually resume sports after the injection to prevent further damage. Herein, we report an unusual case of flexor digitorum profundus rupture after a single corticosteroid injection in a 57-yr-old male golfer and we also present a review of the literature.

  7. MOLECULAR PATHOBIOLOGICAL AND SCANNING ELECTRON MICROSCOPIC CHANGES IN HORSE TENDON CELLS TREA TED WITH ENROFLOXACIN

    Directory of Open Access Journals (Sweden)

    A. Khan1 and J. Halper

    2003-12-01

    Full Text Available Fluoroquinolone (FQNL antibiotics have been used widely in horses because of their broad-spectrum bactericidal activity and relative safety, however, their use is not without risk. Tendonitis and spontaneous tendon rupture have been reported in people during or following therapy with FQNLs. To evaluate the potential damage of enrofloxacin (ENRO on the equine superficial digital flexor tendon (SOFT, an equine cell culture system as an in vitro model of equine tendon injury and repair was developed. The effects of ENRO on tendon cell cultures established from equine SOFT were studied. The data thus collected demonstrated that ENRO inhibited cell proliferation, induced morphological changes and altered proteoglycan synthesis in equine tendon cell cultures. Interestingly, these effects were more pronounced in juvenile tendon cells as compared to adult horses, It. is hypothesized that morphological changes and inhibition of cell proliferation is a result of impaired production of proteoglycans and other glycoproteins in the extracellular matrix of ENRO-treated tendon cells.

  8. Experimental study of the effects of helium-neon laser radiation on repair of injured tendon

    Science.gov (United States)

    Xu, Yong-Qing; Li, Zhu-Yi; Weng, Long-Jiang; An, Mei; Li, Kai-Yun; Chen, Shao-Rong; Wang, Jian-Xin; Lu, Yu

    1993-03-01

    Despite extensive research into the biology of tendon healing, predictably restoring normal function to a digit after a flexor tendon laceration remains one of the most difficult problems facing the hand surgeon. The challenge of simultaneously achieving tendon healing while minimizing the peritendinous scar formation, which limits tendon gliding, has captured the attention of investigators for many years. It has been said that low-power density helium-neon laser radiation had effects on anti-inflammation, detumescence, progressive wound healing, and reducing intestinal adhesions. This experimental study aims at whether helium-neon laser can reduce injured tendon adhesions and improve functional recovery of the injured tendon. Fifty white Leghorn hens were used. Ten were randomly assigned as a normal control group, the other forty were used in the operation. After anesthetizing them with Amytal, a half of the profundus tendons of the second and third foretoes on both sides of the feet were cut. Postoperatively, the hens moved freely in the cages. One side of the toes operated on were randomly chosen as a treatment group, the other side served as an untreated control group. The injured tendon toes in the treatment group were irradiated for twenty minutes daily with a fiber light needle of helium-neon laser therapeutic apparatus (wavelength, 6328 angstroms) at a constant power density of 12.74 mW/cm2, the first exposure taking place 24 hours after the operation. The longest course of treatment was 3 weeks. The control group was not irradiated. At 3 days, 1, 2, 3, and 5 weeks after surgery, 8 hens were sacrificed and their tendons were examined. The experimental results: (1) active, passive flexion and tendon gliding functional recovery were significantly better in the treatment group (p < 0.01); (2) width and thickness of the tendon at the cut site were significantly smaller in the treatment group (p < 0.01); (3) degrees of tendon adhesions were significantly lighter

  9. Comparison of Transverse Intraosseous Loop Technique and Pull Out Suture for Reinsertion of the Flexor Digitorum Profundus tendon. A Retrospective Study.

    Science.gov (United States)

    Rigó, István Zoltán; Røkkum, Magne

    2013-12-01

    We compared the results of two methods for reinsertion of flexor digitorum profundus tendons retrospectively. In 35 fingers of 29 patients pull-out suture and in 13 fingers of 11 patients transverse intraosseous loop technique was performed with a mean follow-up of 8 and 6 months, respectively. Eleven and nine fingers achieved "excellent" or "good" function according to Strickland and Glogovac at 8 weeks; 20 and ten at the last control in the pull-out and transverse intraosseous loop groups, respectively. The difference at 8 weeks was statistically significant in favour of the transverse intraosseous loop group. Ten patients underwent 12 complications in the pull-out group (four superficial infections; one rerupture, one PIP and one DIP joint contracture, one adhesion, two granulomas, one nail deformity and one carpal tunnel syndrome) and four of them were reoperated (one carpal tunnel release, one teno-arthrolysis and two resections of granuloma). There was no complication and no reoperation in the transverse intraosseous loop group, the difference being statistically significant for the former. In our study the transverse intraosseous loop technique seemed to be a safe alternative with possibly better functional results compared to the pull-out suture.

  10. A Rare Case of Deep Digital Flexor Tendinopathy following Centesis of the Navicular Bursa

    Directory of Open Access Journals (Sweden)

    Tim J. Froydenlund

    2017-10-01

    Full Text Available Navicular bursa (NB centesis is a common diagnostic and therapeutic procedure in equine practice. This case report documents the clinical, diagnostic imaging and histological findings in a horse with a suspected iatrogenic deep digital flexor tendon (DDFT injury following centesis of the NB via a modified distal plantar approach (placement of two needles in a weight bearing position. Although it cannot be proven with absolute certainty, the authors believe that this is the first reported case where NB centesis is the likely cause of a DDFT lesion, and with magnetic resonance imaging performed both pre- and post-centesis. With this potential, though rare, complication of the procedure, alternative tendon sparing injection techniques should be considered prior to NB centesis in certain cases.

  11. Readability of the Most Commonly Accessed Online Patient Education Materials Pertaining to Pathology of the Hand.

    Science.gov (United States)

    Akinleye, Sheriff D; Garofolo-Gonzalez, Garret; Montuori, Michael; Culbertson, Maya Deza; Hashem, Jennifer; Edelstein, David Marc

    2017-08-01

    The American Medical Association (AMA) and National Institutes of Health (NIH) recommend that patient education materials be written at no higher than a sixth-grade reading level. We examined 100 online educational materials for the 10 hand conditions most commonly treated by hand surgeons, as reported by the American Society for Surgery of the Hand. The listed conditions were carpal tunnel syndrome, basal joint arthritis of the thumb, de Quervain syndrome, Dupuytren's contracture, ganglion cysts, hand fractures, trigger finger, extensor tendon injuries, flexor tendon injuries, and mallet finger. Following a Google search for each condition, we analyzed the 10 most visited websites for each disorder utilizing the Flesch-Kincaid formula. The average grade reading level of the 100 websites studied was 9.49 with a reading ease of 53.03 ("fairly difficult high school"). Only 29% of the websites were at or below the national average of an eighth-grade reading level. Carpal tunnel syndrome had the highest average grade reading level at 10.32 (standard deviation: 1.52), whereas hand fractures had the lowest at 8.14 (2.03). Every hand condition in this study had an average readability at or above the ninth-grade reading level. The most frequently accessed materials for common maladies of the hand exceed both the readability limits recommended by the AMA and NIH, and the average reading ability of most US adults. Therefore, the most commonly accessed websites pertaining to hand pathology may not be comprehended by the audience for which it is intended.

  12. Comparison of Early Active Tension and Immobilization Protocols in Rehabilitation of the Hand, Following Zone 5-6 Extensor Tendon Repair

    Directory of Open Access Journals (Sweden)

    Fereidoun Layeghi

    2013-07-01

    Full Text Available Objective: The objective of the study was to assess and compare Early Active Tension and Immobilization Protocols in Rehabilitation of the Hand, Following Zone 5-6 Extensor Tendon Repair. Materials & Methods: From the 21 patients enrolled in a randomized controlled trial study, 18 cases with average age of 32. 43 years completed the protocol. A total of 41 extensor tendons from 27 fingers of the subjects were studied. A surgeon repaired all tendons in zone 5 and/or 6 by an end to end epitenon running technique using prolen 0.3. For rehabilitation, subjects were randomly assigned into two “Immobilization” and “early active tension” group. Edema, metacarpophalangeal flexion, combined flexion and extension of wrist and fingers, total active motion of fingers and metacarpal extensor lag were assessed 6 weeks after surgery. All aforementioned variables and grip strength were reassessed 12 weeks after surgery. Results: Compared to traditional immobilization protocol, early active tension could significantly improve hand edema, metacarpal flexion, combined flexion and extension of wrist and fingers, total active motion of fingers and grip strength (P0.05. Conclusion: Our results demonstrate that in compliant patients, early active tension could be an alternative method for traditional immobilization protocol, after surgical repair of extensor tendon injuries in zone 5 and/or 6.

  13. Single dose of inducible nitric oxide synthase inhibitor induces prolonged inflammatory cell accumulation and fibrosis around injured tendon and synovium

    Directory of Open Access Journals (Sweden)

    Homa Darmani

    2004-01-01

    Full Text Available THE aim of the current study was to investigate the effect of inhibition of nitric oxide (NO production after injury on inflammatory cell accumulation and fibrosis around digital flexor tendon and synovium. A standard crush injury was applied to the flexor tendons of the middle digit of the hindpaw and the overlying muscle and synovium of female Wistar rats. Thirty animals received an intraperitoneal injection of either isotonic saline or N(G-nitro-l-arginine methyl ester (L-NAME; 5 mg/kg immediately following the crush injury, and five animals were then sacrificed at various intervals and the paws processed for histology. Another group of five animals was sacrificed after 3 days for nitrite determinations. The results showed that nitrite production and hence NO synthase activity is doubled at the acute phase of tendon wound healing, and we can prevent this by administering a single dose of L-NAME immediately after injury. The incidence and severity of fibrocellular adhesions between tendon and synovium was much more marked in animals treated with L-NAME. Treatment with L-NAME elicited a chronic inflammatory response characterised by a persistent and extraordinarily severe accumulation of large numbers of inflammatory cells in the subcutaneous tissues, in muscle and in tendon. These findings indicate that in the case of injured tendon and synovium, NO could act to protect the healing tissue from an uncontrolled inflammatory response.

  14. Hands in Systemic Disease

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is ... Hand Therapist? Media Find a Hand Surgeon Home Anatomy ... hands, being composed of many types of tissue, including blood vessels, nerves, skin and skin-related tissues, bones, and muscles/tendons/ligaments, may show changes that reflect a ...

  15. Synergistic co-activation increases the extent of mechanical interaction between rat ankle plantar-flexors

    Directory of Open Access Journals (Sweden)

    Chris Tijs

    2016-09-01

    Full Text Available Force transmission between rat ankle plantar-flexors has been found for physiological muscle lengths and relative positions, but only with all muscles maximally activated. The aims of this study were to assess intermuscular mechanical interactions between ankle plantar-flexors during (i fully passive conditions, (ii excitation of soleus (SO, (iii excitation of lateral gastrocnemius (LG, and (iv during co-activation of SO and LG (SO&LG. We assessed effects of proximal lengthening of LG and plantaris (PL muscles (i.e. simulating knee extension on forces exerted at the distal SO tendon (FSO and on the force difference between the proximal and distal LG+PL tendons (ΔFLG+PL of the rat. LG+PL lengthening increased FSO to a larger extent (p=0.017 during LG excitation (0.0026 N/mm than during fully passive conditions (0.0009 N/mm. Changes in FSO in response to LG+PL lengthening were lower (p=0.002 during SO only excitation (0.0056 N/mm than during SO&LG excitation (0.0101 N/mm. LG+PL lengthening changed ∆FLG+PL to a larger extent (p=0.007 during SO excitation (0.0211 N/mm than during fully passive conditions (0.0157 N/mm. In contrast, changes in ∆FLG+PL in response to LG+PL lengthening during LG excitation (0.0331 N/mm were similar (p=0.161 to that during SO&LG excitation (0.0370 N/mm. In all conditions, changes of FSO were lower than those of ∆FLG+PL. This indicates that muscle forces were transmitted not only between LG+PL and SO, but also between LG+PL and other surrounding structures. In addition, epimuscular myofascial force transmission between rat ankle plantar-flexors was enhanced by muscle activation. However, the magnitude of this interaction was limited.

  16. Elbow, forearm, wrist, and hand injuries among sport rock climbers.

    Science.gov (United States)

    Holtzhausen, L M; Noakes, T D

    1996-07-01

    Sport rock climbing with its repetitive high-torque movements in gaining the ascent of a rock face or wall, often in steep overhanging positions, is associated with a unique distribution and form of upper limb injuries. In this article, we review the biomechanical aspects of sport rock climbing and the types of injuries commonly encountered in the forearm, wrist, and hand regions of elite sport rock climbers. Because elbow, forearm, wrist, and hand injuries predominate, representing 62% of the total injuries encountered, these anatomical areas have been selected for review. The predominant source of data are the published work of Bollen et al. The remaining sources were obtained through electronic search of the Medline and Current Contents Databases (last searched May 1995). German and French articles were included in the search criteria. Only studies dealing with acute soft tissue and overuse injuries amongst sport rock climbers were selected. Data were extracted directly from the sourced articles. The following injuries have been described in detail with regard to their presentation, diagnosis, treatment, and prevention amongst sport rock climbers: medial epicondylitis, brachialis tendonitis, biceps brachii tendonitis, ulnar collateral ligament sprain of the elbow, carpal tunnel syndrome, digital flexor tendon pulley sheath tears, interphalangeal joint effusions, fixed flexion deformities of the interphalangeal joints, and collateral ligament tears of the interphalangeal joints. Many of the injuries are specific to the handhold types used by the rock climber. Accurate diagnosis and effective treatment of these unique injuries will be facilitated by a wider understanding of the biomechanical aspects of rock climbing and an awareness of the patterns and incidence of injuries in this sport.

  17. Extensor and flexor digit synovial sheath, sac and synovial capsule in the distal part of the limbs in buffalos and camels and its relation of surgical interference

    Directory of Open Access Journals (Sweden)

    S. AL-sadi

    2010-01-01

    Full Text Available Sixty one samples of the distal parts of limbs were obtained from different ages of buffalo and camels of both sex to study the synovial structures to determine the suitable sites for injection of surgical interference. The result showed that extensor digit synovial sheath was extend between middle or distal part of metacarpal (metatarsal to the extensor processes and this formed with synovial capsule dorsal pouches which serve in surgical interference. The flexor digit synovial sheath extended to palmar (planter between distal extremity of metacarpal (metatarsal to the middle of second phalanx in buffalo while in camel it extended to the proximal extremity of second phalanx, that sheath was formed with suspensory ligament and sessamoid bone palmar or planter pouches which were serve the surgical interference. Fourth synovial bursa observed situated dorsally between the extensor digit laterals tendon and capsule of fetlock joint, forms site of injection during surgical interference, while the other two synovial bursa were located to palmer (planter between deep flexor tendon and distal sessamoid bone in buffalo while in camel these bursa were located between deep flexor tendon and cartilage of the second phalanx, these bursa were served for surgical interference. The synovial capsule which serve the surgical interference through digit cushion these were shown extended from the claw capsule. The result show that surgical interference was form six pouches in buffalo and eight pouches in camel, which formed by synovial structures and the tissue associated with them.

  18. Transverse plane tendon and median nerve motion in the carpal tunnel: ultrasound comparison of carpal tunnel syndrome patients and healthy volunteers.

    Directory of Open Access Journals (Sweden)

    Margriet H M van Doesburg

    Full Text Available The median nerve and flexor tendons are known to translate transversely in the carpal tunnel. The purpose of this study was to investigate these motions in differential finger motion using ultrasound, and to compare them in healthy people and carpal tunnel syndrome patients.Transverse ultrasounds clips were taken during fist, index finger, middle finger and thumb flexion in 29 healthy normal subjects and 29 CTS patients. Displacement in palmar-dorsal and radial-ulnar direction was calculated using Analyze software. Additionally, the distance between the median nerve and the tendons was calculated.We found a changed motion pattern of the median nerve in middle finger, index finger and thumb motion between normal subjects and CTS patients (p<0.05. Also, we found a changed motion direction in CTS patients of the FDS III tendon in fist and middle finger motion, and of the FDS II and flexor pollicis longus tendon in index finger and thumb motion, respectively (p<0.05. The distance between the median nerve and the FDS II or FPL tendon is significantly greater in patients than in healthy volunteers for index finger and thumb motion, respectively (p<0.05.Our results suggest a changed motion pattern of the median nerve and several tendons in carpal tunnel syndrome patients compared to normal subjects. Such motion patterns may be useful in distinguishing affected from unaffected individuals, and in studies of the pathomechanics of carpal tunnel syndrome.

  19. Muscular responses appear to be associated with existence of kinesthetic perception during combination of tendon co-vibration and motor imagery.

    Science.gov (United States)

    Shibata, Eriko; Kaneko, Fuminari; Katayose, Masaki

    2017-11-01

    The afferent inputs from peripheral sensory receptors and efferent signals from the central nervous system that underlie intentional movement can contribute to kinesthetic perception. Previous studies have revealed that tendon vibration to wrist muscles elicits an excitatory response-known as the antagonist vibratory response-in muscles antagonistic to the vibrated muscles. Therefore, the present study aimed to further investigate the effect of tendon vibration combined with motor imagery on kinesthetic perception and muscular activation. Two vibrators were applied to the tendons of the left flexor carpi radialis and extensor carpi radialis. When the vibration frequency was the same between flexors and extensors, no participant perceived movement and no muscle activity was induced. When participants imagined flexing their wrists during tendon vibration, the velocity of perceptual flexion movement increased. Furthermore, muscle activity of the flexor increased only during motor imagery. These results demonstrate that kinesthetic perception can be induced during the combination of motor imagery and co-vibration, even with no experience of kinesthetic perception from an afferent input with co-vibration at the same frequency. Although motor responses were observed during combined co-vibration and motor imagery, no such motor responses were recorded during either co-vibration alone or motor imagery alone, suggesting that muscular responses during the combined condition are associated with kinesthetic perception. Thus, the present findings indicate that kinesthetic perception is influenced by the interaction between afferent input from muscle spindles and the efferent signals that underlie intentional movement. We propose that the physiological behavior resulting from kinesthetic perception affects the process of modifying agonist muscle activity, which will be investigated in a future study.

  20. Digital flexor musculotendinous contracture in two Devon Rex cats.

    Science.gov (United States)

    Thom, Leonie K; Pool, Roy R; Malik, Richard

    2017-03-01

    Clinical summary: A 13-year-old, spayed Devon Rex with unilateral digital flexor musculotendinous contracture of the forelimb was treated by surgical tenotomy. The condition improved transiently, but recurred rapidly and became bilateral. Histopathologic analysis of necropsy tissues resulted in a morphologic diagnosis of fibromyositis of the antebrachial muscles causing contracture and flexural deformity of the carpi and phalanges of both thoracic limbs. A search for similar cases yielded the clinical notes of a second cat, a 10-year-old, spayed Devon Rex, also with bilateral disease. This second case responded well to surgical tenotomy but tissue biopsies were not obtained to permit microscopic assessment of the underlying pathologic process. Relevance and novel information: Acquired and permanent contracture of the digital flexor muscles and/or tendons of the forelimbs is a rare and poorly described condition of cats. The very limited number of documented cases describing disease affecting one or more digits (but not the carpus) infers a causal link with onychectomy, but reported histopathologic changes have been limited to the tendons. The two cases described in this report suffered contracture of the carpus and all digits bilaterally, one without previous onychectomy and the other 9 years after onychectomy. There were novel histopathologic findings in the muscles of the one case for which biopsy material was available. Information gained from these two cases provides a new perspective for the investigation and treatment of future cases. Specifically, consideration should be given to an underlying immune-mediated myopathic process and a possible genetic predisposition in the Devon Rex breed. Currently, the poorly understood etiopathogenesis hinders our ability to definitively recommend treatment options, which might include corticosteroids and other forms of immunosuppressive therapy.

  1. Procedure-Oriented Torsional Anatomy of the Hand for Spasticity Injection.

    Science.gov (United States)

    John, Joslyn; Cianca, John; Chiou-Tan, Faye; Pandit, Sindhu; Furr-Stimming, Erin; Taber, Katherine H

    To provide musculoskeletal ultrasound (MSKUS) images of hand anatomy in the position of hemiparetic flexion as a reference for spasticity injections. After a stroke, spasticity can result in anatomic distortion of the hand. Spasticity may require treatment with botulinum toxin or phenol injections. Anatomic distortion may decrease the accuracy of injections. Standard anatomic references are of limited utility because they are not in this spastic hemiparetic position. There presently is no anatomic reference in the literature for these spastic postures. This study is part three of a series examining torsional anatomy of the body. Ultrasound (US) images were obtained in a healthy subject. The muscles examined included the lumbricals and the flexor pollicis brevis. A marker dot was placed at each dorsal and palmar anatomic injection site for these muscles. The US probe was placed on these dots to obtain a cross-sectional view. A pair of US images was recorded with and without power Doppler imaging: the first in anatomic neutral and second in hemiparetic spastic positions. In addition, a video recording of the movement of the muscles during this rotation was made at each site. On the palmar view, the lumbricals rotated medially. On dorsal view, the lumbricals can be seen deep to the dorsal interossei muscles, with spastic position, and they become difficult to identify. The flexor pollicis brevis (FPB) muscle contracts with torsion, making abductor pollicis brevis (APB) predominately in view. The anatomic location of the lumbrical muscles makes them difficult to inject even with ultrasound guidance. However, recognizing the nearby digital vasculature allows for improved identification of the musculature for injection purposes. The FPB muscle also can be identified by its adjacent radial artery lateral to the flexor pollicus longus tendon. Normal anatomy of hand can become distorted in spastic hemiparesis. Diagnostic ultrasound is able to discern these anatomic

  2. Radial and ulnar bursae of the wrist: cadaveric investigation of regional anatomy with ultrasonographic-guided tenography and MR imaging

    International Nuclear Information System (INIS)

    Aguiar, R.O.C.; Gasparetto, E.L.; Marchiori, E.; Escuissato, D.L.; Trudell, D.J.; Haghighi, P.; Resnik, D.

    2006-01-01

    To demonstrate the anatomy of the radial and ulnar bursae of the wrist using MR and US images. Ultrasonographic-guided tenography of the tendon sheath of flexor pollicis longus (FPL) and the common tendon sheath of the flexor digitorum of the fifth digit (FD5) of ten cadaveric hands was performed, followed by magnetic resonance imaging and gross anatomic correlation. Patterns of communication were observed between these tendon sheaths and the radial and ulnar bursae of the wrist. The tendon sheath of the FPL communicated with the radial bursa in 100% (10/10) of cases, and the tendon sheath of the FD5 communicated with the ulnar bursa in 80% (8/10). Communication of the radial and ulnar bursae was evident in 100% (10/10), and presented an ''hourglass'' configuration in the longitudinal plane. The ulnar and radial bursae often communicate. The radial bursa communicates with the FPL tendon sheath, and the ulnar bursa may communicate with the FD5 tendon sheath

  3. The role of human ankle plantar flexor muscle-tendon interaction and architecture in maximal vertical jumping examined in vivo.

    Science.gov (United States)

    Farris, Dominic James; Lichtwark, Glen A; Brown, Nicholas A T; Cresswell, Andrew G

    2016-02-01

    Humans utilise elastic tendons of lower limb muscles to store and return energy during walking, running and jumping. Anuran and insect species use skeletal structures and/or dynamics in conjunction with similarly compliant structures to amplify muscle power output during jumping. We sought to examine whether human jumpers use similar mechanisms to aid elastic energy usage in the plantar flexor muscles during maximal vertical jumping. Ten male athletes performed maximal vertical squat jumps. Three-dimensional motion capture and a musculoskeletal model were used to determine lower limb kinematics that were combined with ground reaction force data in an inverse dynamics analysis. B-mode ultrasound imaging of the lateral gastrocnemius (GAS) and soleus (SOL) muscles was used to measure muscle fascicle lengths and pennation angles during jumping. Our results highlighted that both GAS and SOL utilised stretch and recoil of their series elastic elements (SEEs) in a catapult-like fashion, which likely serves to maximise ankle joint power. The resistance of supporting of body weight allowed initial stretch of both GAS and SOL SEEs. A proximal-to-distal sequence of joint moments and decreasing effective mechanical advantage early in the extension phase of the jumping movement were observed. This facilitated a further stretch of the SEE of the biarticular GAS and delayed recoil of the SOL SEE. However, effective mechanical advantage did not increase late in the jump to aid recoil of elastic tissues. © 2016. Published by The Company of Biologists Ltd.

  4. Complications arising from a misdiagnosed giant lipoma of the hand and palm: a case report

    Directory of Open Access Journals (Sweden)

    Pagonis Thomas

    2011-11-01

    Full Text Available Abstract Introduction Lipomas are benign tumors which may appear in almost any human organ. Their diagnosis rate in the hand region is not known. Case Presentation We present the case of a 63-year-old Greek Caucasian woman with a giant lipoma of the hand and palm which was not initially diagnosed. After repeated surgical decompression of the carpal tunnel the patient was referred with persisting symptoms of median and ulnar nerve compression and a prominent mass of her left palm and thenar eminence. Clinical examination, magnetic resonance imaging, nerve conduction study and biopsy, revealed a giant lipoma in the deep palmar space (8.0 × 4.0 × 3.75 cm, which was also infiltrating the carpal tunnel. She had already undergone two operations for carpal tunnel syndrome with no relief of her symptoms and she also ended up with a severed flexor pollicis longus tendon. Definitive treatment was performed by marginal resection of the lipoma and restoration of the flexor pollicis longus with an intercalated graft harvested from the palmaris longus. Thirty months after surgery the patient had a fully functional hand without any neurological deficit. Conclusion Not all lipomas of the wrist and hand are diagnosed. Our report tries to emphasize the hidden danger of lipomas in cases with carpal tunnel symptoms. The need for a high index of suspicion in conjunction with good clinical evaluation and the use of appropriate investigative studies is mandatory in order to avoid unnecessary operations and complications. Marginal excision of these tumors is restorative.

  5. Evaluation of the histological and mechanical features of tendon healing in a rabbit model with the use of second-harmonic-generation imaging and tensile testing.

    Science.gov (United States)

    Hase, E; Sato, K; Yonekura, D; Minamikawa, T; Takahashi, M; Yasui, T

    2016-11-01

    This study aimed to evaluate the histological and mechanical features of tendon healing in a rabbit model with second-harmonic-generation (SHG) imaging and tensile testing. A total of eight male Japanese white rabbits were used for this study. The flexor digitorum tendons in their right leg were sharply transected, and then were repaired by intratendinous stitching. At four weeks post-operatively, the rabbits were killed and the flexor digitorum tendons in both right and left legs were excised and used as specimens for tendon healing (n = 8) and control (n = 8), respectively. Each specimen was examined by SHG imaging, followed by tensile testing, and the results of the two testing modalities were assessed for correlation. While the SHG light intensity of the healing tendon samples was significantly lower than that of the uninjured tendon samples, 2D Fourier transform SHG images showed a clear difference in collagen fibre structure between the uninjured and the healing samples, and among the healing samples. The mean intensity of the SHG image showed a moderate correlation (R 2 = 0.37) with Young's modulus obtained from the tensile testing. Our results indicate that SHG microscopy may be a potential indicator of tendon healing.Cite this article: E. Hase, K. Sato, D. Yonekura, T. Minamikawa, M. Takahashi, T. Yasui. Evaluation of the histological and mechanical features of tendon healing in a rabbit model with the use of second-harmonic-generation imaging and tensile testing. Bone Joint Res 2016;5:577-585. DOI: 10.1302/2046-3758.511.BJR-2016-0162.R1. © 2016 Yasui et al.

  6. Stiff Hands

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is a Hand Surgeon? What is a Hand Therapist? Media Find a Hand Surgeon Home Anatomy Stiff Hands Email to a friend * required fields ...

  7. Hand Infections

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is a Hand Surgeon? What is a Hand Therapist? Media Find a Hand Surgeon Home Anatomy Hand Infections Email to a friend * required fields ...

  8. Acute calcific tendonitis of dorsal interosseous muscles of the hand: uncommon site of a frequent disease

    Directory of Open Access Journals (Sweden)

    D. Schneider

    2017-05-01

    Full Text Available Acute calcific tendinopathy is one of the manifestations of hydroxyapatite crystal deposition disease. While it is more frequent in the shoulder, it has been described in virtually all areas of the body, but rarely in the muscles of the hand. Its etiopathogenesis is not yet fully understood and despite being a fairly frequent condition, it is commonly misdiagnosed. The onset of the disease is usually acute and resolves spontaneously. Acute calcific tendinitis of the interosseous tendons of the hand is an uncommon site of a frequent condition. The clinical presentation is similar to other entities, thus errors in diagnosis frequently occur, resulting in over-treatment or unnecessary tests. We describe a case of acute calcific tendinitis of the interosseous muscles of the hand with a brief review of the current literature with emphasis on diagnostic imaging methods.

  9. Anterior cruciate ligament graft tensioning. Is the maximal sustained one-handed pull technique reproducible?

    Directory of Open Access Journals (Sweden)

    Hirpara Kieran M

    2011-07-01

    Full Text Available Abstract Background Tensioning of anterior cruciate ligament (ACL reconstruction grafts affects the clinical outcome of the procedure. As yet, no consensus has been reached regarding the optimum initial tension in an ACL graft. Most surgeons rely on the maximal sustained one-handed pull technique for graft tension. We aim to determine if this technique is reproducible from patient to patient. Findings We created a device to simulate ACL reconstruction surgery using Ilizarov components and porcine flexor tendons. Six experienced ACL reconstruction surgeons volunteered to tension porcine grafts using the device to see if they could produce a consistent tension. None of the surgeons involved were able to accurately reproduce graft tension over a series of repeat trials. Conclusions We conclude that the maximal sustained one-handed pull technique of ACL graft tensioning is not reproducible from trial to trial. We also conclude that the initial tension placed on an ACL graft varies from surgeon to surgeon.

  10. Anterior cruciate ligament graft tensioning. Is the maximal sustained one-handed pull technique reproducible?

    LENUS (Irish Health Repository)

    O'Neill, Barry J

    2011-07-20

    Abstract Background Tensioning of anterior cruciate ligament (ACL) reconstruction grafts affects the clinical outcome of the procedure. As yet, no consensus has been reached regarding the optimum initial tension in an ACL graft. Most surgeons rely on the maximal sustained one-handed pull technique for graft tension. We aim to determine if this technique is reproducible from patient to patient. Findings We created a device to simulate ACL reconstruction surgery using Ilizarov components and porcine flexor tendons. Six experienced ACL reconstruction surgeons volunteered to tension porcine grafts using the device to see if they could produce a consistent tension. None of the surgeons involved were able to accurately reproduce graft tension over a series of repeat trials. Conclusions We conclude that the maximal sustained one-handed pull technique of ACL graft tensioning is not reproducible from trial to trial. We also conclude that the initial tension placed on an ACL graft varies from surgeon to surgeon.

  11. Rabbit Achilles tendon full transection model - wound healing, adhesion formation and biomechanics at 3, 6 and 12 weeks post-surgery.

    Science.gov (United States)

    Meier Bürgisser, Gabriella; Calcagni, Maurizio; Bachmann, Elias; Fessel, Gion; Snedeker, Jess G; Giovanoli, Pietro; Buschmann, Johanna

    2016-09-15

    After tendon rupture repair, two main problems may occur: re-rupture and adhesion formation. Suitable non-murine animal models are needed to study the healing tendon in terms of biomechanical properties and extent of adhesion formation. In this study 24 New Zealand White rabbits received a full transection of the Achilles tendon 2 cm above the calcaneus, sutured with a 4-strand Becker suture. Post-surgical analysis was performed at 3, 6 and 12 weeks. In the 6-week group, animals received a cast either in a 180 deg stretched position during 6 weeks (adhesion provoking immobilization), or were re-casted with a 150 deg position after 3 weeks (adhesion inhibiting immobilization), while in the other groups (3 and 12 weeks) a 180 deg position cast was applied for 3 weeks. Adhesion extent was analyzed by histology and ultrasound. Histopathological scoring was performed according to a method by Stoll et al. (2011), and the main biomechanical properties were assessed. Histopathological scores increased as a function of time, but did not reach values of healthy tendons after 12 weeks (only around 15 out of 20 points). Adhesion provoking immobilization led to an adhesion extent of 82.7±9.7%, while adhesion inhibiting immobilization led to 31.9±9.8% after 6 weeks. Biomechanical properties increased over time, however, they did not reach full strength nor elastic modulus at 12 weeks post-operation. Furthermore, the rabbit Achilles tendon model can be modulated in terms of adhesion formation to the surrounding tissue. It clearly shows the different healing stages in terms of histopathology and offers a suitable model regarding biomechanics because it exhibits similar biomechanics as the human flexor tendons of the hand. © 2016. Published by The Company of Biologists Ltd.

  12. Rabbit Achilles tendon full transection model – wound healing, adhesion formation and biomechanics at 3, 6 and 12 weeks post-surgery

    Directory of Open Access Journals (Sweden)

    Gabriella Meier Bürgisser

    2016-09-01

    Full Text Available After tendon rupture repair, two main problems may occur: re-rupture and adhesion formation. Suitable non-murine animal models are needed to study the healing tendon in terms of biomechanical properties and extent of adhesion formation. In this study 24 New Zealand White rabbits received a full transection of the Achilles tendon 2 cm above the calcaneus, sutured with a 4-strand Becker suture. Post-surgical analysis was performed at 3, 6 and 12 weeks. In the 6-week group, animals received a cast either in a 180 deg stretched position during 6 weeks (adhesion provoking immobilization, or were re-casted with a 150 deg position after 3 weeks (adhesion inhibiting immobilization, while in the other groups (3 and 12 weeks a 180 deg position cast was applied for 3 weeks. Adhesion extent was analyzed by histology and ultrasound. Histopathological scoring was performed according to a method by Stoll et al. (2011, and the main biomechanical properties were assessed. Histopathological scores increased as a function of time, but did not reach values of healthy tendons after 12 weeks (only around 15 out of 20 points. Adhesion provoking immobilization led to an adhesion extent of 82.7±9.7%, while adhesion inhibiting immobilization led to 31.9±9.8% after 6 weeks. Biomechanical properties increased over time, however, they did not reach full strength nor elastic modulus at 12 weeks post-operation. Furthermore, the rabbit Achilles tendon model can be modulated in terms of adhesion formation to the surrounding tissue. It clearly shows the different healing stages in terms of histopathology and offers a suitable model regarding biomechanics because it exhibits similar biomechanics as the human flexor tendons of the hand.

  13. Rabbit Achilles tendon full transection model – wound healing, adhesion formation and biomechanics at 3, 6 and 12 weeks post-surgery

    Science.gov (United States)

    Meier Bürgisser, Gabriella; Calcagni, Maurizio; Bachmann, Elias; Fessel, Gion; Snedeker, Jess G.; Giovanoli, Pietro

    2016-01-01

    ABSTRACT After tendon rupture repair, two main problems may occur: re-rupture and adhesion formation. Suitable non-murine animal models are needed to study the healing tendon in terms of biomechanical properties and extent of adhesion formation. In this study 24 New Zealand White rabbits received a full transection of the Achilles tendon 2 cm above the calcaneus, sutured with a 4-strand Becker suture. Post-surgical analysis was performed at 3, 6 and 12 weeks. In the 6-week group, animals received a cast either in a 180 deg stretched position during 6 weeks (adhesion provoking immobilization), or were re-casted with a 150 deg position after 3 weeks (adhesion inhibiting immobilization), while in the other groups (3 and 12 weeks) a 180 deg position cast was applied for 3 weeks. Adhesion extent was analyzed by histology and ultrasound. Histopathological scoring was performed according to a method by Stoll et al. (2011), and the main biomechanical properties were assessed. Histopathological scores increased as a function of time, but did not reach values of healthy tendons after 12 weeks (only around 15 out of 20 points). Adhesion provoking immobilization led to an adhesion extent of 82.7±9.7%, while adhesion inhibiting immobilization led to 31.9±9.8% after 6 weeks. Biomechanical properties increased over time, however, they did not reach full strength nor elastic modulus at 12 weeks post-operation. Furthermore, the rabbit Achilles tendon model can be modulated in terms of adhesion formation to the surrounding tissue. It clearly shows the different healing stages in terms of histopathology and offers a suitable model regarding biomechanics because it exhibits similar biomechanics as the human flexor tendons of the hand. PMID:27635037

  14. Hand Surgery: Anesthesia

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is a Hand Surgeon? What is a Hand Therapist? Media Find a Hand Surgeon Home Anatomy Hand Surgery Anesthesia Email to a friend * required ...

  15. Severe Hand Injuries Caused by a Mole Gun

    Directory of Open Access Journals (Sweden)

    Serdar Düzgün

    2017-10-01

    Full Text Available Objective: Injuries by mole guns differ from other firearm injuries primarily because they are close-range, low-energy injuries that are highly contaminated owing to contact with contaminated surfaces and the presence of numerous residual foreign bodies within the wound. The aim of this article is to share our surgical experience regarding the repair of severe hand injuries caused by mole guns. Material and Methods: This retrospective study included 11 patients with hand injuries. Data obtained about the patients, including age, gender, dominant or non-dominant hand, injuries to all vital structures, and reconstructive procedures were assessed, categorized, and recorded. Results: Ten patients had defects in one or several common digital branches of the median nerve in areas ranging from the distal part of the carpal tunnel to the distal palmar crease. All patients had flexor and extensor tendon injuries in all fingers except for the first finger. Reconstruction of soft tissue and skin defects was carried out with an interpolation flap planned from a random-based subpectoral- paraumbilical region in five patients, a SCIA-based groin flap in four patients, a reverse-radial forearm flap in one patient, and an adipofascial flap planned from the forearm in one patient. Conclusion: Mole gun injuries typically include all structures of the hand, and repair procedures involve every anatomic structure of the hand. An early and effective surgical operation followed by prolonged and effective physical therapy protocols is vital for regaining the full spectrum of hand functions.

  16. Functional characterization of detergent-decellularized equine tendon extracellular matrix for tissue engineering applications.

    Directory of Open Access Journals (Sweden)

    Daniel W Youngstrom

    Full Text Available Natural extracellular matrix provides a number of distinct advantages for engineering replacement orthopedic tissue due to its intrinsic functional properties. The goal of this study was to optimize a biologically derived scaffold for tendon tissue engineering using equine flexor digitorum superficialis tendons. We investigated changes in scaffold composition and ultrastructure in response to several mechanical, detergent and enzymatic decellularization protocols using microscopic techniques and a panel of biochemical assays to evaluate total protein, collagen, glycosaminoglycan, and deoxyribonucleic acid content. Biocompatibility was also assessed with static mesenchymal stem cell (MSC culture. Implementation of a combination of freeze/thaw cycles, incubation in 2% sodium dodecyl sulfate (SDS, trypsinization, treatment with DNase-I, and ethanol sterilization produced a non-cytotoxic biomaterial free of appreciable residual cellular debris with no significant modification of biomechanical properties. These decellularized tendon scaffolds (DTS are suitable for complex tissue engineering applications, as they provide a clean slate for cell culture while maintaining native three-dimensional architecture.

  17. Is passive stiffness in human muscles related to the elasticity of tendon structures?

    Science.gov (United States)

    Kubo, K; Kanehisa, H; Fukunaga, T

    2001-08-01

    The purpose of this study was to examine in vivo whether passive stiffness in human muscles was related to the elasticity of tendon structures and to performance during stretch-shortening cycle exercise. Passive torque of plantar flexor muscles was measured during passive stretch from 90 degrees (anatomical position) to 65 degrees of dorsiflexion at a constant velocity of 5 degrees.s-1. The slope of the linear portion of the passive torque-angle curve during stretching was defined as the passive stiffness of the muscle. The elongation of the tendon and aponeurosis of the medial gastrocnemius muscle (MG) was directly measured using ultrasonography during ramp isometric plantar flexion up to the voluntary maximum. The relationship between the estimated muscle force of MG and tendon elongation was fitted to a linear regression, the slope of which was defined as the stiffness of the tendon. In addition, the dynamic torques during maximal voluntary concentric plantar flexion with and without prior eccentric contraction were determined at a constant velocity of 120 degrees.s-1. There were no significant correlations between passive stiffness and either the tendon stiffness (r = 0.19, P > 0.05) or the relative increase in torque with prior eccentric contraction (r = -0.19, P > 0.05). However, tendon stiffness was negatively correlated to the relative increase in torque output (r = -0.42, P tendon structures, and had no favourable effect on the muscle performance during stretch-shortening cycle exercise.

  18. Hand Fractures

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is ... Hand Therapist? Media Find a Hand Surgeon Home Anatomy ... DESCRIPTION The bones of the hand serve as a framework. This framework supports the muscles that make the wrist and fingers move. When ...

  19. Regional molecular and cellular differences in the female rabbit Achilles tendon complex: potential implications for understanding responses to loading.

    Science.gov (United States)

    Huisman, Elise S; Andersson, Gustav; Scott, Alexander; Reno, Carol R; Hart, David A; Thornton, Gail M

    2014-05-01

    The aim of this study was: (i) to analyze the morphology and expression of extracellular matrix genes in six different regions of the Achilles tendon complex of intact normal rabbits; and (ii) to assess the effect of ovariohysterectomy (OVH) on the regional expression of these genes. Female New Zealand White rabbits were separated into two groups: (i) intact normal rabbits (n = 4); and (ii) OVH rabbits (n = 8). For each rabbit, the Achilles tendon complex was dissected into six regions: distal gastrocnemius (DG); distal flexor digitorum superficialis; proximal lateral gastrocnemius (PLG); proximal medial gastrocnemius; proximal flexor digitorum superficialis; and paratenon. For each of the regions, hematoxylin and eosin staining was performed for histological evaluation of intact normal rabbit tissues and mRNA levels for proteoglycans, collagens and genes associated with collagen regulation were assessed by real-time reverse transcription-quantitative polymerase chain reaction for both the intact normal and OVH rabbit tissues. The distal regions displayed a more fibrocartilaginous phenotype. For intact normal rabbits, aggrecan mRNA expression was higher in the distal regions of the Achilles tendon complex compared with the proximal regions. Collagen Type I and matrix metalloproteinase-2 expression levels were increased in the PLG compared to the DG in the intact normal rabbit tissues. The tendons from OVH rabbits had lower gene expressions for the proteoglycans aggrecan, biglycan, decorin and versican compared with the intact normal rabbits, although the regional differences of increased aggrecan expression in distal regions compared with proximal regions persisted. The tensile and compressive forces experienced in the examined regions may be related to the regional differences found in gene expression. The lower mRNA expression of the genes examined in the OVH group confirms a potential effect of systemic estrogen on tendon. © 2014 Anatomical Society.

  20. Muscle response to pneumatic hand tool torque reaction forces.

    Science.gov (United States)

    Radwin, R G; VanBergeijk, E; Armstrong, T J

    1989-06-01

    Surface electromyography was used for studying the effects of torque reaction force acting against the hand, on forearm muscle activity and grip force for five subjects operating right angle, air shut-off nutrunners. Four tools having increasing spindle torque were operated using short and long torque reaction times. Nutrunner spindle torque ranged between 30 Nm and 100 Nm. Short torque reaction time was considered 0.5 s while long torque reaction time was 2 s. Peak horizontal force was the greatest component of the reaction force acting against the hand and accounted for more than 97% of the peak resultant hand force. Peak hand force increased from 89 N for the smallest tool to 202 N for the largest tool. Forearm muscle rms EMG, scaled for grip force, indicated average flexor activity during the Torque-reaction phase was more than four times greater than the Pre-start and Post Shut-off phases, and two times greater than the Run-down phase. Flexor EMG activity during the Torque-reaction phase increased for increasing tool peak spindle torque. Average flexor rms EMG activity, scaled for grip force, during the Torque-reaction phase increased from 372 N for the 30 Nm nutrunner to 449 N for the 100 Nm nutrunner. Flexor rms EMG activity averaged during the Torque-reaction phase and scaled for grip force was 390 N for long torque reaction times and increased to 440 N for short torque reaction times. Flexor rms EMG integrated over the torque reaction phase was 839 Ns for long torque reaction times and decreased to 312 Ns for short torque reaction times. The average latency between tool spindle torque onset and peak initial flexor rms EMG for long torque reaction times was 294 ms which decreased to 161 ms for short torque reaction times. The average latency between peak tool spindle torque, just prior to tool shut-off, and peak final rms EMG for long torque reaction times was 97 ms for flexors and 188 ms for extensors, which decreased for short torque reaction times to 47

  1. Sport-Specific Capacity to Use Elastic Energy in the Patellar and Achilles Tendons of Elite Athletes.

    Science.gov (United States)

    Wiesinger, Hans-Peter; Rieder, Florian; Kösters, Alexander; Müller, Erich; Seynnes, Olivier R

    2017-01-01

    Introduction: During running and jumping activities, elastic energy is utilized to enhance muscle mechanical output and efficiency. However, training-induced variations in tendon spring-like properties remain under-investigated. The present work extends earlier findings on sport-specific profiles of tendon stiffness and cross-sectional area to examine whether years of distinct loading patterns are reflected by tendons' ability to store and return energy. Methods: Ultrasound scans were performed to examine the morphological features of knee extensor and plantar flexor muscle-tendon units in elite ski jumpers, distance runners, water polo players, and sedentary controls. Tendon strain energy and hysteresis were measured with combined motion capture, ultrasonography, and dynamometry. Results: Apart from the fractional muscle-to-tendon cross-sectional area ratio being lower in the knee extensors of ski jumpers (-31%) and runners (-33%) than in water polo players, no difference in the considered muscle-tendon unit morphological features was observed between groups. Similarly, no significant difference in tendon energy storage or energy return was detected between groups. In contrast, hysteresis was lower in the patellar tendon of ski jumpers (-33%) and runners (-30%) compared to controls, with a similar trend for the Achilles tendon (significant interaction effect and large effect sizes η 2 = 0.2). Normalized to body mass, the recovered strain energy of the patellar tendon was ~50% higher in ski jumpers than in water polo players and controls. For the Achilles tendon, recovered strain energy was ~40% higher in ski jumpers and runners than in controls. Discussion: Advantageous mechanical properties related to tendon spring-like function are observed in elite athletes whose sport require effective utilization of elastic energy. However, the mechanisms underpinning the better tendon capacity of some athletes to retain elastic energy could not be ascribed to intrinsic or

  2. Case report

    African Journals Online (AJOL)

    ebutamanya

    2015-11-20

    Nov 20, 2015 ... We report a case of a farmer who has sustained of a severe hand wound due to ... open distal interphalangeal joint dislocation of the 5th finger; flexor tendons were .... biomechanical analysis and clinical application. J Orthop ...

  3. Effects of flunixin meglumine on experimental tendon wound healing: A histopathological and mechanical study in rabbits

    Directory of Open Access Journals (Sweden)

    Mehdi Behfar

    2014-12-01

    Full Text Available Tendons are frequently targets of injury in sports and work. Whether nonsteroidal anti-inflammatory drugs (NSAIDs have beneficial effects on tendon healing is still a matter of debate. This study was conducted to evaluate effects of flunixin meglumine (FM on tendon healing after experimentally induced acute trauma. Twenty eight adult male New Zealand White rabbits were subjected to complete transection of deep digital flexor tendons followed by suture placement. Treatment group received intramuscular injection of FM for three days, and controls received placebo. Subsequently, cast immobilization was continued for two weeks. Animals were sacrificed four weeks after surgery and tissue samples were taken. The histological evaluations revealed improved structural characteristics of neotendon formation including fibrillar linearity, fibrillar continuity and neovascularization in treatment group compared to those of controls (p 0.05. Mechanical evaluation revealed significant increase in load-related material properties including ultimate load, yield load, energy absorption and ultimate stress in treatment group compared to those of control group (p 0.05. The present study showed that intramuscular injection of FM resulted in improved structural and mechanical properties of tendon repairs and it could be an effective treatment for acute tendon injuries like severance and laceration.

  4. Adipose derived stromal vascular fraction improves early tendon healing: an experimental study in rabbits

    Directory of Open Access Journals (Sweden)

    Mehdi Behfar

    2011-11-01

    Full Text Available Tendon never restores the complete biological and mechanical properties after healing. Bone marrow and recently adipose tissue have been used as the sources of mesenchymal stem cells, which have been proven to enhance tendon healing. Stromal vascular fraction (SVF, derived from adipose tissue by an enzymatic digestion, represents an alternative source of multipotent cells, which undergo differentiation into multiple lineages to be used in regenerative medicine. In the present study, we investigated potentials of this source on tendon healing. Twenty rabbits were divided into control and treatment groups. Five rabbits were used as donors of adipose tissue. The injury model was unilateral complete transection through the middle one third of deep digital flexor tendon. Immediately after suture repair, either fresh stromal vascular fraction from enzymatic digestion of adipose tissue or placebo was intratendinously injected into the suture site in treatments and controls, respectively. Cast immobilization was continued for two weeks after surgery. Animals were sacrificed at the third week and tendons underwent histological, immunohistochemical, and mechanical evaluations. By histology, improved fibrillar organization and remodeling of neotendon were observed in treatment group. Immunohistochemistry revealed an insignificant increase in collagen type III and I expression in treatments over controls. Mechanical testing showed significant increase in maximum load and energy absorption in SVF treated tendons. The present study showed that intratendinous injection of uncultured adipose derived stromal vascular fraction improved structural and mechanical properties of repaired tendon and it could be an effective modality for treating tendon laceration.

  5. Computed tomography-guided bupivacaine and corticosteroid injection for the treatment of symptomatic calcification in the great toe tendon

    Directory of Open Access Journals (Sweden)

    Karatoprak O

    2014-04-01

    Full Text Available Omer Karatoprak,1 Sinan Karaca,2 Mehmet Nuri Erdem,3 Ozgur Karaman,2 Azmi Hamzaoglu41Department of Orthopedic Surgery, Kadikoy Florence Nightingale Hospital, Istanbul, Turkey; 2Department of Orthopedic Surgery, Fatih Sultan Mehmet Training and Research Hospital Atasehir, Istanbul, Turkey; 3Department of Orthopedics and Traumatology, Kolan International Hospital Sisli, Istanbul, Turkey; 4Department of Orthopedic Surgery, Istanbul Florence Nightingale Hospital, Istanbul TurkeyBackground: Calcification in the great toe tendon is a rare disorder that is characterized by the deposition of calcium on degenerative collagen fibrils.Case presentations: In this report, we present two cases of calcific tendonitis: one in the adductor hallucis and the other in the flexor hallucis longus tendon. We preferred computed tomography-guided steroid injection in our cases because of pain unresponsive to conservative treatment. Patients were free of symptoms at the follow-up visit, 4 weeks after injection.Conclusion: Calcification of the hallux tendons is a rare disorder. Treatment of tendonitis consists of nonsteroidal anti-inflammatory drugs. Local anesthetic and steroid injection may be considered in cases unresponsive to conservative treatment. Because of the anatomic location of tendons, injection could be difficult. Computed tomography guidance may improve the success rate of injections.Keywords: bupivacaine, calcification, great toe tendons, corticosteroid injection

  6. Proteomic analysis reveals age-related changes in tendon matrix composition, with age- and injury-specific matrix fragmentation.

    Science.gov (United States)

    Peffers, Mandy J; Thorpe, Chavaunne T; Collins, John A; Eong, Robin; Wei, Timothy K J; Screen, Hazel R C; Clegg, Peter D

    2014-09-12

    Energy storing tendons, such as the human Achilles and equine superficial digital flexor tendon (SDFT), are highly prone to injury, the incidence of which increases with aging. The cellular and molecular mechanisms that result in increased injury in aged tendons are not well established but are thought to result in altered matrix turnover. However, little attempt has been made to fully characterize the tendon proteome nor determine how the abundance of specific tendon proteins changes with aging and/or injury. The aim of this study was, therefore, to assess the protein profile of normal SDFTs from young and old horses using label-free relative quantification to identify differentially abundant proteins and peptide fragments between age groups. The protein profile of injured SDFTs from young and old horses was also assessed. The results demonstrate distinct proteomic profiles in young and old tendon, with alterations in the levels of proteins involved in matrix organization and regulation of cell tension. Furthermore, we identified several new peptide fragments (neopeptides) present in aged tendons, suggesting that there are age-specific cleavage patterns within the SDFT. Proteomic profile also differed between young and old injured tendon, with a greater number of neopeptides identified in young injured tendon. This study has increased the knowledge of molecular events associated with tendon aging and injury, suggesting that maintenance and repair of tendon tissue may be reduced in aged individuals and may help to explain why the risk of injury increases with aging. © 2014 by The American Society for Biochemistry and Molecular Biology, Inc.

  7. Clinical follow-up of horses treated with allogeneic equine mesenchymal stem cells derived from umbilical cord blood for different tendon and ligament disorders.

    Science.gov (United States)

    Van Loon, Vic J F; Scheffer, Carmen J W; Genn, Herman J; Hoogendoorn, Arie C; Greve, Jan W

    2014-01-01

    Mesenchymal stem cells (MSCs) offer promise as therapeutic aids in the repair of tendon and ligament disorders in sport horses. Equine allogeneic MSCs derived from umbilical cord blood (eUCB-MSCs) can be obtained in a minimally invasive fashion with successful propagation of MSCs. The objective of this study was to determine the applicability and therapeutic effect of eUCB-MSCs on tendinitis of the superficial digital flexor tendon, desmitis of the suspensory ligament, tendinitis of the deep digital flexor tendon, and desmitis of the inferior check ligament in clinical cases. A retrospective clinical study was performed. At two equine clinics, 52 warmblood horses were treated with cultured eUCB-MSCs between 2009 and 2012. About 2-10 × 10(6) cells per lesion were administered. When a lesion was treated twice, the total amount could run up to 20 × 10(6) cells. Pearson's chi-squared test was used to compare the effect of the injured structure on the success rate, as well as the effect of the age of the horse. Based on repeated examinations, 40 horses (77%) returned to work on the same or a higher level based on information provided by the owner. Neither the injured structure nor the age of the horse had a statistically significant influence on the result. Overall, the results of treatment of some tendon and ligament injuries with eUCB-MSCs in clinical cases are promising.

  8. MR anatomy study of the elbow, with emphasis in ligaments and tendons structure - methodology

    International Nuclear Information System (INIS)

    Vilela, Sonia de Aguiar; Fernandes, Artur da Rocha Correa; Barbieri, Antonio; Turrini, Elisabete; Juliano, Yara

    1999-01-01

    Seventeen MR exams of the elbow joints of fifteen healthy volunteers were obtained on T1 spin-echo sequences in the transversal, coronal and sagital planes. Eight anatomic structures were selected and evaluated by three independent blind readers. The aim of this study was to establish the frequency of visibility as well to determine the best plane to characterize these anatomic structures and also to analyze the interobserver variability. The readers analyzed the exams using the same criteria: degree 0 (structure not visible); degree 1 (structure visible and partially delineated); degree 2 (structure well visible and well delineated). The structure visibility showed variability close related to the degree (1 or 2) chosen by the readers to define the structure visualization and mainly in the transverse plane. The coronal plane was showed to be the ideal to evaluate the collateral ligaments, the common extensor tendon and the com,mon flexor tendon, otherwise the sagital plane was useful to define triceps and braquial tendons. The biceps tendon and annular ligament were well defined in the transverse plane. The usefulness of this study is to establish the ideal planes to evaluate these anatomic structures, and develop faster protocols. (author)

  9. Knee flexor strength recovery following hamstring tendon harvest for anterior cruciate ligament reconstruction: a systematic review

    Directory of Open Access Journals (Sweden)

    Clare Ardern

    2009-07-01

    Full Text Available The hamstring tendons are an increasingly popular graft choice for anterior cruciate ligament reconstruction due to preservation of quadriceps function and the absence of anterior knee pain post-operatively. Two commonly used hamstring grafts are a quadruple strand semitendinosus graft (4ST and a double strand semitendinosus-double strand gracilis graft (2ST-2G. It has been suggested that concurrent harvest of the semitendinsous and gracilis tendons may result in sub-optimal hamstring strength recovery as the gracilis may play a role in reinforcing the semitendinosus particularly in deep knee flexion angles. The objective of this systematic review was to synthesize the findings of available literature and determine whether semitendinosus and gracilis harvest lead to post-operative hamstring strength deficits when compared to semitendinosus harvest alone. Seven studies were identified which compared hamstring strength outcomes between the common hamstring graft types. The methodological quality of each paper was assessed, and where possible effect sizes were calculated to allow comparison of results across studies. No differences were reported between the groups in isokinetic hamstring strength. Deficits in hamstring strength were reported in the 2ST-2G groups when compared to the 4ST groups in isometric strength testing at knee flexion angles ≥70°, and in the standing knee flexion angle. Preliminary evidence exists to support the hypothesis that harvesting the semitendinosus tendon alone is preferable to harvesting in combination with the gracilis tendon for minimizing post-operative hamstring strength deficits at knee flexion angles greater than 70°. However, due to the paucity of research comparing strength outcomes between the common hamstring graft types, further investigation is warranted to fully elucidate the implications for graft harvest.

  10. Effect of exercise on age-related changes in collagen fibril diameter distributions in the common digital extensor tendons of young horses.

    Science.gov (United States)

    Edwards, Lindsey J; Goodship, Allen E; Birch, Helen L; Patterson-Kane, Janet C

    2005-04-01

    To determine whether specific treadmill exercise regimens would accelerate age-related changes in collagen fibril diameter distributions in the common digital extensor tendon (CDET) of the forelimbs of young Thoroughbreds. 24 female Thoroughbreds. Horses were trained for 18 weeks (6 horses; short term) or 18 months (5 horses; long term) on a high-speed treadmill; 2 age-matched control groups (6 horses/group) performed walking exercise only. Horses were (mean +/- SD) 24 +/- 1 months and 39 +/- 1 months old at termination of the short-term and long-term regimens, respectively. Midmetacarpal CDET specimens were obtained and processed for transmission electron microscopy. Diameter and area of at least 1,000 collagen fibrils/specimen were measured by use of computerized image analysis. Mass-average diameter (MAD) of collagen fibrils and collagen fibril index were calculated for each horse. Collagen fibril MAD for the older horses was significantly less than that for the younger horses. Exercise did not significantly affect fibril diameter or distributions in either age group, and collagen fibril index did not differ significantly between groups. Age-related reduction in collagen fibril MAD agreed with findings for other tendons and species. Training did not accelerate age-related change in the CDET in contrast to a reported decrease in collagen fibril MAD in the superficial digital flexor tendon of horses trained long term. Our results support the concept that the functionally distinct nature of the CDET and superficial digital flexor tendon in horses results in fundamentally different responses to high-speed exercise regimens.

  11. Osteoarthritis of the Hand

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is a Hand Surgeon? What is a Hand Therapist? Media Find a Hand Surgeon Home Anatomy Osteoarthritis Email to a friend * required fields From * ...

  12. Tendon sheath fibroma in the thigh.

    Science.gov (United States)

    Moretti, Vincent M; Ashana, Adedayo O; de la Cruz, Michael; Lackman, Richard D

    2012-04-01

    Tendon sheath fibromas are rare, benign soft tissue tumors that are predominantly found in the fingers, hands, and wrists of young adult men. This article describes a tendon sheath fibroma that developed in the thigh of a 70-year-old man, the only known tendon sheath fibroma to form in this location. Similar to tendon sheath fibromas that develop elsewhere, our patient's lesion presented as a painless, slow-growing soft tissue nodule. Physical examination revealed a firm, nontender mass with no other associated signs or symptoms. Although the imaging appearance of tendon sheath fibromas varies, our patient's lesion appeared dark on T1- and bright on T2-weighted magnetic resonance imaging. It was well marginated and enhanced with contrast.Histologically, tendon sheath fibromas are composed of dense fibrocollagenous stromas with scattered spindle-shaped fibroblasts and narrow slit-like vascular spaces. Most tendon sheath fibromas can be successfully removed by marginal excision, although 24% of lesions recur. No lesions have metastasized. Our patient's tendon sheath fibroma was removed by marginal excision, and the patient remained disease free 35 months postoperatively. Despite its rarity, tendon sheath fibroma should be included in the differential diagnosis of a thigh mass on physical examination or imaging, especially if it is painless, nontender, benign appearing, and present in men. Copyright 2012, SLACK Incorporated.

  13. Magnetic resonance imaging findings in patients with medial epicondylitis

    Energy Technology Data Exchange (ETDEWEB)

    Kijowski, Richard; Smet, Arthur A. De [University of Wisconsin Hospital, Department of Radiology, Madison (United States)

    2005-04-01

    To compare the MR imaging findings of 13 patients with clinically diagnosed medial epicondylitis with the MR imaging findings of 26 patients of similar age with no clinical evidence of medial epicondylitis. The study group consisted of 13 patients with clinically diagnosed medial epicondylitis. The control group consisted of 26 patients of similar age with no clinical evidence of medial epicondylitis. The medical records and MR imaging findings of these patients were retrospectively reviewed by two fellowship-trained musculoskeletal radiologists. Eleven of the 13 patients in the study group had thickening and increased signal intensity of the common flexor tendon on both T1-weighted and T2-weighted images. The remaining two patients in the study group had soft tissue edema around a normal-appearing common flexor tendon. Twenty-one of the 26 patients in the control group had a normal-appearing common flexor tendon on MR imaging. Three patients in the control group had a thickened common flexor tendon which was of intermediate signal intensity on T1-weighted images but of uniform low signal intensity on T2-weighted images. Two patients in the control group had a thickened common flexor tendon which was of intermediate signal intensity on both T1-weighted and T2-weighted images. None of the patients in the control group had soft tissue edema around the common flexor tendon. MR imaging findings of patients with clinically diagnosed medial epicondylitis included thickening and increased T1 and T2 signal intensity of the common flexor tendon and soft tissue edema around the common flexor tendon. The presence of intermediate to high T2 signal intensity or high T2 signal intensity within the common flexor tendon and the presence of paratendinous soft tissue edema were the most specific findings of medial epicondylitis on MR imaging. (orig.)

  14. Performance Comparison Between FEDERICA Hand and LARM Hand

    OpenAIRE

    Carbone, Giuseppe; Rossi, Cesare; Savino, Sergio

    2015-01-01

    This paper describes two robotic hands that have been\\ud developed at University Federico II of Naples and at the\\ud University of Cassino. FEDERICA Hand and LARM Hand\\ud are described in terms of design and operational features.\\ud In particular, careful attention is paid to the differences\\ud between the above-mentioned hands in terms of transmission\\ud systems. FEDERICA Hand uses tendons and pulleys\\ud to drive phalanxes, while LARM Hand uses cross four-bar\\ud linkages. Results of experime...

  15. Effects of plyometric and isometric training on muscle and tendon stiffness in vivo.

    Science.gov (United States)

    Kubo, Keitaro; Ishigaki, Tomonobu; Ikebukuro, Toshihiro

    2017-08-01

    The purpose of this study was to compare the effects of plyometric and isometric training on tendon properties during ramp and ballistic contractions and muscle stiffness under passive and active conditions. Eleven subjects completed 12 weeks (3 days/week) of a unilateral training program for the plantar flexors. They performed plyometric training on one side (PLY) and isometric training on the other side (ISO). Active muscle stiffness in the medial gastrocnemius muscle was calculated according to changes in estimated muscle force and fascicle length during fast stretching after submaximal isometric contractions. Passive muscle stiffness was also calculated from estimated passive muscle force and fascicle length during slow passive stretching. Stiffness and hysteresis of tendon structures were measured using ultrasonography during ramp and ballistic contractions. Passive muscle stiffness and tendon hysteresis did not change for PLY or ISO Active muscle stiffness significantly increased for PLY, but not for ISO Tendon stiffness during ramp and ballistic contractions increased significantly for ISO, but not for PLY In addition, tendon elongation values at force production levels beyond 100 N during ballistic contractions increased for PLY These results suggest that plyometric training (but not isometric training) enhances the extensibility of tendon structures during ballistic contractions and active muscle stiffness during fast stretching, and these changes may be related to improved performances during stretch-shortening cycle exercises. © 2017 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.

  16. Tracking of autologous adipose tissue-derived mesenchymal stromal cells with in vivo magnetic resonance imaging and histology after intralesional treatment of artificial equine tendon lesions : A pilot study

    NARCIS (Netherlands)

    Geburek, Florian; Mundle, Kathrin; Conrad, Sabine; Hellige, Maren; Walliser, Ulrich; van Schie, Hans T M; van Weeren, René; Skutella, Thomas; Stadler, Peter M

    2016-01-01

    BACKGROUND: Adipose tissue-derived mesenchymal stromal cells (AT-MSCs) are frequently used to treat equine tendinopathies. Up to now, knowledge about the fate of autologous AT-MSCs after intralesional injection into equine superficial digital flexor tendons (SDFTs) is very limited. The purpose of

  17. Análise biomecânica e histológica de tendões flexores reparados em coelhos usando três técnicas de sutura (quatro e seis passadas com mobilização ativa precoce Biomechanics and histological analysis in rabbit flexor tendons repaired using three suture techniques (four and six strands with early active mobilization

    Directory of Open Access Journals (Sweden)

    Antônio Lourenço Severo

    2012-02-01

    Full Text Available OBJETIVO: Analisar o tempo das suturas, a biomecânica (deformidade entre os cotos tendíneos e a histologia dos três grupos de reparo cirúrgico tendíneo: Brasil-2 (quatro passadas, com técnica de sutura central em que o nó final se encontra fora do tendão; Indiana (quatro passadas; e Tsai (seis passadas, com técnicas de sutura central em que o nó final se encontra no interior do tendão reparado, associados de mobilização ativa precoce. MÉTODOS: O tendão calcâneo direito de 36 coelhos da raça New Zealand foi escolhido para a análise. Este apresenta calibre semelhante ao tendão flexor humano, o qual tem aproximadamente 4,5mm (variando 2mm para mais ou menos. A amostra selecionada apresentava a mesma massa (2,5 a 3kg e eram adultos machos ou fêmeas (a partir de 8½ meses de idade. RESULTADOS: Na análise biomecânica, não houve diferença estatisticamente significativa (p > 0,01. Não houve diferença estatística com relação ao tempo cirúrgico na realização das três técnicas de suturas (p > 0,01. Evidenciou-se, qualitativamente e quantitativamente, com a mobilidade ativa precoce, um espessamento da fibra de colágeno em 38,9% dentro do 15º dia e de 66,7% dentro do período do 30º dia (p = 0,095. CONCLUSÃO: Esta investigação serviu para demonstrar que não houve diferença histológica do nó final da sutura central dentro ou fora do tendão reparado, bem como o número de passadas, no que diz respeito à cicatrização, vascularização ou deformidade do tendão no túnel osteofibroso com as técnicas de reparo aplicadas, associados de mobilização ativa precoce.OBJECTIVE: analyzing suture time, biomechanics (deformity between the stumps and the histology of three groups of tendinous surgical repair: Brazil-2 (4-strands which the end knot (core is located outside the tendon, Indiana (4-strands and Tsai (6-strands with sutures technique which the end knot (core is inner of the tendon, associated with early active

  18. Detailed analysis of contrast-enhanced MRI of hands and wrists in patients with psoriatic arthritis

    International Nuclear Information System (INIS)

    Tehranzadeh, Jamshid; Ashikyan, Oganes; Anavim, Arash; Shin, John

    2008-01-01

    The objective was to perform detailed analysis of the involved soft tissues, tendons, joints, and bones in the hands and wrists of patients with psoriatic arthritis (PsA). We reviewed 23 contrast-enhanced MR imaging studies (13 hands and 10 wrists) in 10 patients with the clinical diagnosis of PsA. We obtained clinical information from medical records and evaluated images for the presence of erosions, bone marrow edema, joint synovitis, tenosynovitis, carpal tunnel, and soft tissue involvement. Two board-certified musculoskeletal radiologists reviewed all images independently. Differences were resolved during a subsequent joint session. The average duration of disease was 71.3 months, ranging from 1 month to 25 years. Eight of the 10 wrists (80%) and 6 of the 13 hands demonstrated bone erosions. Bone marrow abnormalities were shown in 5 of the 10 wrists (50%) and 4 of the 14 hands (31%). Triangular fibrocartilage tears were seen in 6 of the 10 wrists (60%). Wrist and hand joint synovitis were present in all studies (67 wrist joints and 101 hand joints). Wrist soft tissue involvement was detected in 9 of the 10 wrists (90%) and hand soft tissue involvement was present in 12 of the 13 wrists (92%). Findings adjacent to the region of soft tissue involvement included synovitis (4 wrists) and tenosynovitis (3 wrists). Bone marrow edema adjacent to the region of soft tissue involvement was seen in one wrist. Bulge of the flexor retinaculum was seen in 4 of the 10 wrists (40%) and median nerve enhancement was seen in 8 of the 10 wrists (80%). Tenosynovitis was seen in all studies (all 10 of the hands and all 13 of the wrists). The ''rheumatoid'' type of distribution of bony lesions was common in our study. Interobserver agreement for various findings ranged from 83% to 100%. Contrast-enhanced MRI unequivocally demonstrated bone marrow edema, erosions, tendon and soft-tissue disease, and median nerve involvement, with good interobserver reliability in patients with PsA of

  19. Detailed analysis of contrast-enhanced MRI of hands and wrists in patients with psoriatic arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Tehranzadeh, Jamshid [University of California, Department of Radiological Sciences, Irvine (United States); University of California Medical Center, Department of Radiological Sciences R-140, Orange, CA (United States); Ashikyan, Oganes; Anavim, Arash; Shin, John [University of California, Department of Radiological Sciences, Irvine (United States)

    2008-05-15

    The objective was to perform detailed analysis of the involved soft tissues, tendons, joints, and bones in the hands and wrists of patients with psoriatic arthritis (PsA). We reviewed 23 contrast-enhanced MR imaging studies (13 hands and 10 wrists) in 10 patients with the clinical diagnosis of PsA. We obtained clinical information from medical records and evaluated images for the presence of erosions, bone marrow edema, joint synovitis, tenosynovitis, carpal tunnel, and soft tissue involvement. Two board-certified musculoskeletal radiologists reviewed all images independently. Differences were resolved during a subsequent joint session. The average duration of disease was 71.3 months, ranging from 1 month to 25 years. Eight of the 10 wrists (80%) and 6 of the 13 hands demonstrated bone erosions. Bone marrow abnormalities were shown in 5 of the 10 wrists (50%) and 4 of the 14 hands (31%). Triangular fibrocartilage tears were seen in 6 of the 10 wrists (60%). Wrist and hand joint synovitis were present in all studies (67 wrist joints and 101 hand joints). Wrist soft tissue involvement was detected in 9 of the 10 wrists (90%) and hand soft tissue involvement was present in 12 of the 13 wrists (92%). Findings adjacent to the region of soft tissue involvement included synovitis (4 wrists) and tenosynovitis (3 wrists). Bone marrow edema adjacent to the region of soft tissue involvement was seen in one wrist. Bulge of the flexor retinaculum was seen in 4 of the 10 wrists (40%) and median nerve enhancement was seen in 8 of the 10 wrists (80%). Tenosynovitis was seen in all studies (all 10 of the hands and all 13 of the wrists). The 'rheumatoid' type of distribution of bony lesions was common in our study. Interobserver agreement for various findings ranged from 83% to 100%. Contrast-enhanced MRI unequivocally demonstrated bone marrow edema, erosions, tendon and soft-tissue disease, and median nerve involvement, with good interobserver reliability in patients with

  20. Fixation of the Achilles tendon insertion using suture button technology.

    Science.gov (United States)

    Fanter, Nathan J; Davis, Edward W; Baker, Champ L

    2012-09-01

    In the operative treatment of Achilles insertional tendinopathy, no guidelines exist concerning which form of fixation of the Achilles tendon insertion is superior. Transcalcaneal drill pin passage does not place any major plantar structures at risk, and the addition of a Krackow stitch and suture button to the fixation technique provides a significant increase in ultimate load to failure in Achilles tendon insertional repairs. Controlled laboratory study. The Achilles tendon insertions in 6 fresh-frozen cadaveric ankles were detached, and transcalcaneal drill pins were passed. Plantar dissection took place to evaluate the drill pin relationship to the plantar fascia, lateral plantar nerve and artery, flexor digitorum longus tendon, and master knot of Henry. The Achilles tendons were then repaired with a double-row suture anchor construct alone or with a suture button and Krackow stitch added to the double-row suture anchor construct. The repairs were then tested to maximum load to failure at 20 mm/min. The mode of failure was recorded, and the mean maximum load to failure was assessed using the Student t test for distributions with equal variance. Transcalcaneal drill pin passage did not place any selected anatomic structures at risk. The mean maximum load to failure for the suture bridge group was 239.2 N; it was 391.4 N for the group with the suture button (P = .014). The lateral plantar artery was the structure placed at greatest risk from drill pin placement, with a mean distance of 22.7 mm (range, 16.5-29.2 mm) between the pin and artery. In this laboratory study, transcalcaneal drill pin passage appeared to be anatomically safe, and the use of suture button technology with a Krackow stitch for Achilles tendon insertional repair significantly increased repair strength. Achilles tendon insertional repair with suture button fixation and a Krackow stitch may facilitate the earlier institution of postoperative rehabilitation and improve clinical outcomes.

  1. Localized type Volkmann's contracture treated with tendon transfer and tension-reduced early mobilization

    Science.gov (United States)

    Kaji, Yoshio; Nakamura, Osamu; Yamaguchi, Konosuke; Tobiume, Sachiko; Yamamoto, Tetsuji

    2017-01-01

    Abstract Rationale: For localized type Volkmann's contracture, in which degeneration of the flexor digitorum profundus (FDP) muscle to one or two fingers and restriction of finger extension occur, dissection or excision of the affected muscle is usually recommended. However, these surgical procedures need relatively wide exposure of the muscle, because the FDP muscle is in the deep portion of the forearm. Patient concerns: In this report, the case of a 35-year-old woman with localized type Volkmann's contracture is presented. Her left forearm had been compressed with an industrial roller 4 months earlier, and severe flexion contracture of the long finger and mild flexion contracture of the ring finger developed gradually. Diagnoses: localized type Volkmann's contracture. Intervention: Five months after the injury, transection of the FDP tendon to the long finger and transfer of the transected tendon to the FDP tendon to the index finger was performed after adjusting the tonus of these two tendons using a small skin incision. This procedure was followed by a tension-reduced early mobilization technique in which a tension-reduced position of the tendon suture site was maintained by taping the long finger to the volar side of the index finger, and then immediate active range of motion (ROM) exercise was started. Outcomes: Within 9 weeks after surgery, full ROM had been regained. Lessons: Using the treatment procedure presented in this case report, a good clinical result was obtained in a minimally invasive manner. PMID:28072735

  2. 4-corner arthrodesis and proximal row carpectomy: a biomechanical comparison of wrist motion and tendon forces.

    Science.gov (United States)

    Debottis, Daniel P; Werner, Frederick W; Sutton, Levi G; Harley, Brian J

    2013-05-01

    Controversy exists as to whether a proximal row carpectomy (PRC) is a better procedure than scaphoid excision with 4-corner arthrodesis for preserving motion in the painful posttraumatic arthritic wrist. The purpose of this study was to determine how the kinematics and tendon forces of the wrist are altered after PRC and 4-corner arthrodesis. We tested 6 fresh cadaver forearms for the extremes of wrist motion and then used a wrist simulator to move them through 4 cyclic dynamic wrist motions, during which time we continuously recorded the tendon forces. We repeated the extremes of wrist motion measurements and the dynamic motions after scaphoid excision with 4-corner arthrodesis, and then again after PRC. We analyzed extremes of wrist motion and the peak tendon forces required for each dynamic motion using a repeated measures analysis of variance. Wrist extremes of motion significantly decreased after both the PRC and 4-corner arthrodesis compared with the intact wrist. Wrist flexion decreased on average 13° after 4-corner arthrodesis and 12° after PRC. Extension decreased 20° after 4-corner arthrodesis and 12° after PRC. Four-corner arthrodesis significantly decreased wrist ulnar deviation from the intact wrist. Four-corner arthrodesis allowed more radial deviation but less ulnar deviation than the PRC. The average peak tendon force was significantly greater after 4-corner arthrodesis than after PRC for the extensor carpi ulnaris during wrist flexion-extension, circumduction, and dart throw motions. The peak forces were significantly greater after 4-corner arthrodesis than in the intact wrist for the extensor carpi ulnaris during the dart throw motion and for the flexor carpi ulnaris during the circumduction motion. The peak extensor carpi radialis brevis force after PRC was significantly less than in the intact wrist. The measured wrist extremes of motion decreased after both 4-corner arthrodesis and PRC. Larger peak tendon forces were required to achieve

  3. Use of smartphones and portable media devices for quantifying human movement characteristics of gait, tendon reflex response, and Parkinson's disease hand tremor.

    Science.gov (United States)

    LeMoyne, Robert; Mastroianni, Timothy

    2015-01-01

    Smartphones and portable media devices are both equipped with sensor components, such as accelerometers. A software application enables these devices to function as a robust wireless accelerometer platform. The recorded accelerometer waveform can be transmitted wireless as an e-mail attachment through connectivity to the Internet. The implication of such devices as a wireless accelerometer platform is the experimental and post-processing locations can be placed anywhere in the world. Gait was quantified by mounting a smartphone or portable media device proximal to the lateral malleolus of the ankle joint. Attributes of the gait cycle were quantified with a considerable accuracy and reliability. The patellar tendon reflex response was quantified by using the device in tandem with a potential energy impact pendulum to evoke the patellar tendon reflex. The acceleration waveform maximum acceleration feature of the reflex response displayed considerable accuracy and reliability. By mounting the smartphone or portable media device to the dorsum of the hand through a glove, Parkinson's disease hand tremor was quantified and contrasted with significance to a non-Parkinson's disease steady hand control. With the methods advocated in this chapter, any aspect of human movement may be quantified through smartphones or portable media devices and post-processed anywhere in the world. These wearable devices are anticipated to substantially impact the biomedical and healthcare industry.

  4. Arthritis of the hand - Rheumatoid

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is a Hand Surgeon? What is a Hand Therapist? Media Find a Hand Surgeon Home Anatomy Rheumatoid Arthritis Email to a friend * required fields ...

  5. Effects of repeated vibratory stimulation of wrist and elbow flexors on hand dexterity, strength, and sensory function in patients with chronic stroke: a pilot study.

    Science.gov (United States)

    Choi, Won-Ho

    2017-04-01

    [Purpose] The aim of this study was to investigate the effects of repeated vibratory stimulation to muscles related to hand functions on dexterity, strength, and sensory function in patients with chronic stroke. [Subjects and Methods] A total of 10 stroke patients with hemiplegia participated in this study. They were divided into two groups: a) Experimental and b) Control, with five randomly selected subjects for each group. The experimental group received vibratory stimulation, while the control group received the traditional physical therapy. Both interventions were performed for 30 minutes each session, three times a week for four weeks. [Results] There was a significant within-group improvement in the box and block test results in both groups for dexterity. Grip strength improved in both groups but the improvement was not statistically significant. [Conclusion] The vibratory stimulation activated the biceps brachii and flexor carpi radialis, which increased dexterity to grasp and lift the box and block from the surface. Therefore, repeated vibratory stimulation to muscles related to hand functions improved hand dexterity equality to the traditional physical therapy in patients with chronic stroke.

  6. THEORETICAL AND EXPERIMENTAL STUDY ON DURABILITY OF THE CALCANEAL TENDON AND THE PATHOMECHANISM OF ITS ATRAUMATIC, SUBCUTANEOUS BREAK

    Directory of Open Access Journals (Sweden)

    K. Skiba

    2011-11-01

    Full Text Available The pathology of the calcaneal tendon (Achilles presents a serious medical and social problem. This tendon is the strongest plantar flexor of the foot that plays a fundamental role in the accomplishment of human gait. Although this role has long been recognized, neither in medical nor in biomechanical literature can one find a clear description of subcutaneous break of the Achilles tendon. Its pathomechanism and the causes have not been fully accounted for. Many authors concentrate mainly on medical and biological aspects of the damage of the Achilles tendon.They often claim that the vasculature of the tendon itself plays a significant role in the pathogenesis, because the blood supply to the tendon changes with human age, decreasing substantially after the age of 30, leading both to regressive changes in the tendon as well as to a reduction of the tendon’s mechanical strength. The refore a comprehensive description and explanation of this phenomenon needs an interdisciplinary approach, taking into account not only the medical and biological aspects, but also the mechanics sensu largo. The aim of the paper is to put forward a complete description of the pathomechanism of the Achilles tendon spontaneous break, within the framework of its mechanics. The conclusions are based upon a kinematical analysis of the knee joint, a trajectory determination of the point of origin of the gastrocnemius from the initial position of 90 degrees bent up to the full knee extension, and an experimental examination of uniaxial stretching of the Achilles tendon.

  7. [Reconstruction of the extensor pollicis longus tendon by transposition of the extensor indicis tendon].

    Science.gov (United States)

    Loos, A; Kalb, K; Van Schoonhoven, J; Landsleitner Dagger, B

    2003-12-01

    Rupture of the extensor pollicis longus-tendon (EPL) is a frequent complication after distal radius fractures. Other traumatic and non-traumatic reasons for this tendon lesion are known, including a theory about a disorder in the blood supply to the tendon itself. We examined 40 patients after reconstruction of the EPL-tendon in a mean follow-up time of 30 months. All patients were clinically examined and a DASH questionnaire was answered by all patients. The method to reconstruct the EPL-tendon was the transposition of the extensor indicis-tendon. After the operations the thumb was put in a splint for four weeks in a "hitch-hiker's-position". 31 ruptures of the tendon (77.5 %) were a result of trauma. In 20 of them (50 %) a distal radius fracture had occurred. Clinical examination included measurements of the movement of the thumb- and index-finger joints, the grip strength and the maximal span of the hand. Significant differences were not found. The isolated extension of the index finger was possible in all patients. But it was reduced in ten cases which represent 25 %. Our results were evaluated by the Geldmacher score to evaluate the reconstruction of the EPL-tendon. 20 % excellent, 65 % good, 12.5 % fair and 2.5 % poor results were reached. The Geldmacher score was used critically. We suggest its modification for the evaluation of thumb abduction. The DASH score reached a functional value of ten points which represents a very good result. In conclusion the extensor indicis-transposition is a safe method to reconstruct the EPL-tendon. Its substantial advantage is taking a healthy muscle as the motor, thereby avoiding the risk of using a degenerated muscle in late tendon reconstruction. A powerful extension of the index finger will be maintained by physical education. Generally, the loss of the extension of the index finger is negligible. It does not disturb the patients. But it has to be discussed with the patient before the operation.

  8. Incidence of tendon entrapment and dislocation with calcaneus and pilon fractures on CT examination

    Energy Technology Data Exchange (ETDEWEB)

    Tresley, Jonathan [Jackson Memorial Hospital, Department of Diagnostic Radiology, Miami, FL (United States); University of Wisconsin-Madison, Department of Radiology, Madison, WI (United States); Subhawong, Ty K.; Singer, Adam D.; Clifford, Paul D. [Jackson Memorial Hospital, Department of Diagnostic Radiology, Miami, FL (United States)

    2016-07-15

    To examine the association between tibial pilon and calcaneal fracture classification and tendon entrapment or dislocation. After institutional review board approval, we retrospectively reviewed consecutive CT scans with calcaneal or pilon fractures from 5 years at a level 1 trauma center. We categorized calcaneal fractures according to the Sanders classification, and pilon fractures according to the Ruedi and Allgower and the Arbeitsgemeinschaft fuer Osteosynthesefragen-Orthopaedic Trauma Association (AO-OTA) classifications. Ankle tendons were assessed for dislocation or entrapment. Fisher's exact test was used for statistical analysis with significance at p < 0.05. A total of 312 fractures (91 pilon only, 193 calcaneal only, and 14 ankles with ipsilateral pilon and calcaneal fractures) were identified in 273 patients. Twenty-two pilon, 42 calcaneal, and nine combination fractures were associated with 99 occurrences of tendon entrapment or superior peroneal retinacular injury. Such findings were associated with multiple fractures (p = 0.002). Multifragmentary pilon fractures were associated with posterior tibial and flexor digitorum longus tendon entrapment (p < 0.0001 and p = 0.0003 for Ruedi/Allgower and AO-OTA, respectively), and multifragmentary Sanders type 3 or 4 calcaneal fractures were associated with superior peroneal retinacular injury (p = 0.0473) compared to simple fracture patterns. Thirty-nine percent of tendon entrapments or retinacular injuries were prospectively identified, 85 % by musculoskeletal radiologists (p < 0.0001). Approximately 25 % of calcaneal and pilon fractures were retrospectively identified to contain posteromedial tendon entrapment or superior peroneal retinacular injury. Radiologists should meticulously search for such injuries, particularly when analyzing multifragmentary and multiple fractures. (orig.)

  9. Incidence of tendon entrapment and dislocation with calcaneus and pilon fractures on CT examination

    International Nuclear Information System (INIS)

    Tresley, Jonathan; Subhawong, Ty K.; Singer, Adam D.; Clifford, Paul D.

    2016-01-01

    To examine the association between tibial pilon and calcaneal fracture classification and tendon entrapment or dislocation. After institutional review board approval, we retrospectively reviewed consecutive CT scans with calcaneal or pilon fractures from 5 years at a level 1 trauma center. We categorized calcaneal fractures according to the Sanders classification, and pilon fractures according to the Ruedi and Allgower and the Arbeitsgemeinschaft fuer Osteosynthesefragen-Orthopaedic Trauma Association (AO-OTA) classifications. Ankle tendons were assessed for dislocation or entrapment. Fisher's exact test was used for statistical analysis with significance at p < 0.05. A total of 312 fractures (91 pilon only, 193 calcaneal only, and 14 ankles with ipsilateral pilon and calcaneal fractures) were identified in 273 patients. Twenty-two pilon, 42 calcaneal, and nine combination fractures were associated with 99 occurrences of tendon entrapment or superior peroneal retinacular injury. Such findings were associated with multiple fractures (p = 0.002). Multifragmentary pilon fractures were associated with posterior tibial and flexor digitorum longus tendon entrapment (p < 0.0001 and p = 0.0003 for Ruedi/Allgower and AO-OTA, respectively), and multifragmentary Sanders type 3 or 4 calcaneal fractures were associated with superior peroneal retinacular injury (p = 0.0473) compared to simple fracture patterns. Thirty-nine percent of tendon entrapments or retinacular injuries were prospectively identified, 85 % by musculoskeletal radiologists (p < 0.0001). Approximately 25 % of calcaneal and pilon fractures were retrospectively identified to contain posteromedial tendon entrapment or superior peroneal retinacular injury. Radiologists should meticulously search for such injuries, particularly when analyzing multifragmentary and multiple fractures. (orig.)

  10. A Barbed Suture Repair For Flexor Tendons: A Novel Technique With No Exposed Barbs

    Directory of Open Access Journals (Sweden)

    Cormac W. Joyce, MB BCh

    2014-10-01

    Conclusions: We demonstrated that a 4-strand knotless, barbed method attained comparable strength to that of the traditional Adelaide repair technique. The barbed method had a significantly reduced cross-sectional area at the repair site compared with the Adelaide group. The 2-mm gap formation force was less in the barbed group than the Adelaide group. Barbed repairs show promise for tendon repairs; this simple method warrants further study in an animal model.

  11. MR imaging of the finger tendons: Normal anatomy and commonly encountered pathology

    International Nuclear Information System (INIS)

    Ragheb, Dina; Stanley, Anthony; Gentili, Amilcare; Hughes, Tudor; Chung, Christine B.

    2005-01-01

    MR imaging has emerged as a powerful tool in the evaluation of soft tissue structures such as the tendons of the hand and finger due to its excellent soft tissue contrast and multiplanar imaging capabilities. In the finger and hand, perhaps more than in any other location in the body, a detailed and intimate understanding of anatomy is crucial for lesion localization, directing clinical management and predicting long-term prognosis. These issues are of paramount importance to both the clinician and imager, both faced with the challenge of the complex anatomy and pathology associated with these delicate structures. The anatomy of the finger including intrinsic and extrinsic muscles, retinacular structures, and tendons will be discussed. The MR imaging features of common lesions of the tendons of the hand and finger will be reviewed

  12. Biomechanical comparison of the four-strand cruciate and Strickland techniques in animal tendons

    Directory of Open Access Journals (Sweden)

    Raquel Bernardelli Iamaguchi

    2013-12-01

    Full Text Available OBJECTIVE: The objective of this study was to compare two four-strand techniques: the traditional Strickland and cruciate techniques. METHODS: Thirty-eight Achilles tendons were removed from 19 rabbits and were assigned to two groups based on suture technique (Group 1, Strickland suture; Group 2, cruciate repair. The sutured tendons were subjected to constant progressive distraction using a universal testing machine (Kratos®. Based on data from the instrument, which were synchronized with the visualized gap at the suture site and at the time of suture rupture, the following data were obtained: maximum load to rupture, maximum deformation or gap, time elapsed until failure, and stiffness. RESULTS: In the statistical analysis, the data were parametric and unpaired, and by Kolmogorov-Smirnov test, the sample distribution was normal. By Student's t-test, there was no significant difference in any of the data: the cruciate repair sutures had slightly better mean stiffness, and the Strickland sutures had longer time-elapsed suture ruptures and higher average maximum deformation. CONCLUSIONS: The cruciate and Strickland techniques for flexor tendon sutures have similar mechanical characteristics in vitro.

  13. Development and validation of the OMERACT rheumatoid arthritis magnetic resonance tenosynovitis scoring system in a multireader exercise

    DEFF Research Database (Denmark)

    Glinatsi, Daniel; Bird, Paul; Gandjbakhch, Frédérique

    2017-01-01

    Objective: To develop and validate a magnetic resonance imaging (MRI) tenosynovitis (TS) score for tendons at the wrist and metacarpophalangeal (MCP) joint levels in patients with rheumatoid arthritis (RA). Methods: Axial T1-weighted precontrast and postcontrast fat-saturated MR image sets...... of the hands of 43 patients with RA initiating rituximab therapy were obtained at baseline and after 14, 26, 38, or 52 weeks. The MR images were scored twice by 4 readers. Nine tendon compartments of the wrist and 4 flexor tendon compartments at the MCP joints were assessed. Tenosynovitis was scored as follows...

  14. Numerical models for prestressing tendons in containment structures

    International Nuclear Information System (INIS)

    Kwak, Hyo-Gyoung; Kim, Jae Hong

    2006-01-01

    Two modified stress-strain relations for bonded and unbonded internal tendons are proposed. The proposed relations can simulate the post-cracking behavior and tension stiffening effect in prestressed concrete containment structures. In the case of the bonded tendon, tensile forces between adjacent cracks are transmitted from a bonded tendon to concrete by bond forces. Therefore, the constitutive law of a bonded tendon stiffened by grout needs to be determined from the bond-slip relationship. On the other hand, a stress increase beyond the effective prestress in an unbonded tendon is not section-dependent but member-dependent. It means that the tendon stress unequivocally represents a uniform distribution along the length when the friction loss is excluded. Thus, using a strain reduction factor, the modified stress-strain curve of an unbonded tendon is derived by successive iterations. In advance, the prediction of cracking behavior and ultimate resisting capacity of prestressed concrete containment structures using the introduced numerical models are succeeded, and the need for the consideration of many influencing factors such as the tension stiffening effect, plastic hinge length and modification of stress-strain relation of tendon is emphasized. Finally, the developed numerical models are applied to prestressed concrete containment structures to verify the efficiency and applicability in simulating the structural behavior with bonded and/or unbonded tendons

  15. Transverse Carpal Ligament and Forearm Fascia Release for the Treatment of Carpal Tunnel Syndrome Change the Entrance Angle of Flexor Tendons to the A1 Pulley: The Relationship between Carpal Tunnel Surgery and Trigger Finger Occurence

    Directory of Open Access Journals (Sweden)

    Nazım Karalezli

    2013-01-01

    Full Text Available Purpose. The appearance of trigger finger after decompression of the carpal tunnel without a preexisting symptom has been reported in a few articles. Although, the cause is not clear yet, the loss of pulley action of the transverse carpal ligament has been accused mostly. In this study, we planned a biomechanical approach to fresh cadavers. Methods. The study was performed on 10 fresh amputees of the arm. The angles were measured with (1 the transverse carpal ligament and the distal forearm fascia intact, (2 only the transverse carpal ligament incised, (3 the distal forearm fascia incised to the point 3 cm proximal from the most proximal part of the transverse carpal ligament in addition to the transverse carpal ligament. The changes between the angles produced at all three conditions were compared to each other. Results. We saw that the entrance angle increased in all of five fingers in an increasing manner from procedure 1 to 3, and it was seen that the maximal increase is detected in the middle finger from procedure 1 to procedure 2 and the minimal increase is detected in little finger. Discussion. Our results support that transverse carpal ligament and forearm fascia release may be a predisposing factor for the development of trigger finger by the effect of changing the enterance angle to the A1 pulley and consequently increase the friction in this anatomic area. Clinical Relevance. This study is a cadaveric study which is directly investigating the effect of a transverse carpal ligament release on the enterance angle of flexor tendons to A1 pulleys in the hand.

  16. Enthesiopathy of the flexor carpi ulnaris at the pisiform: Findings of high-frequency sonography

    Energy Technology Data Exchange (ETDEWEB)

    Wick, Marius C., E-mail: marius.wick@i-med.ac.at [Department of Radiology, Innsbruck Medical University, Anichstrasse 35, A-6020 Innsbruck (Austria); Weiss, Ruediger J., E-mail: rudiger.weiss@karolinska.se [Department of Molecular Medicine and Surgery, Section of Orthopaedics and Sports Medicine, Karolinska University Hospital (Solna), Karolinska Institutet, S-17176 Stockholm (Sweden); Arora, Rohit, E-mail: rohit.arora@uki.at [Department for Trauma Surgery and Sports Medicine, Innsbruck Medical University, Anichstrasse 35, A-6020 Innsbruck (Austria); Gabl, Markus, E-mail: markus.gabl@uki.at [Department for Trauma Surgery and Sports Medicine, Innsbruck Medical University, Anichstrasse 35, A-6020 Innsbruck (Austria); Gruber, Johann, E-mail: johann.gruber@uki.at [Department of Internal Medicine I, Innsbruck Medical University, Anichstrasse 35, A-6020 Innsbruck (Austria); Jaschke, Werner, E-mail: werner.jaschke@i-med.ac.at [Department of Radiology, Innsbruck Medical University, Anichstrasse 35, A-6020 Innsbruck (Austria); Klauser, Andrea S., E-mail: andrea.klauser@i-med.ac.at [Department of Radiology, Innsbruck Medical University, Anichstrasse 35, A-6020 Innsbruck (Austria)

    2011-02-15

    Objectives: Acute or chronic pain at the pisiform may be due to tendinopathy of the flexor carpi ulnaris tendon (FCU) insertion, mechanical overuse, bony fractures, and osteoarthritis of the pisiform-triquetral joint. Enthesiopathy of the FCU at the pisiform might exhibit abnormalities assessable for sonographic characterization. This study aimed to determine the most relevant sonographic features of tendinopathy of the FCU insertion at the pisiform. Materials and methods: We retrospectively analyzed radiological findings of 9 patients admitted for high-frequency sonographic evaluation of a painful pisiform FCU insertion. The FCU insertion was assessed for active enthesiopathy in terms of tendon thickening and hyperemia, peritendinous effusion, peritendinous hyperemia, peritendinous soft tissue thickening, cystic fluid collections, erosive cortical irregularities, and osteoproliferative alterations at the pisiform. Results: Of all patients, 5 had inflammatory rheumatic disorders and the remainder had a painful pisiform FCU insertion related to overuse. While peritendinous effusion, pisiform erosive cortical irregularities, and peritendinous soft tissue thickening at the FCU insertion were exclusively found in rheumatic patients, active enthesiopathy of the FCU tendon, pisiform osteoproliferative alterations, and hyperemia of the peritendinous soft tissue were inconsistent and found in both groups. Cystic fluid collections from the pisiform-triquetral joint were only seen in patients with overuse. Conclusions: In this small case series of patients with pain at the pisiform FCU insertion, we could reveal several typical sonographic features for insertion tendinopathy. Further studies should prove if these sonographic features could impact on the management of patients with pain at the pisiform.

  17. Enthesiopathy of the flexor carpi ulnaris at the pisiform: Findings of high-frequency sonography

    International Nuclear Information System (INIS)

    Wick, Marius C.; Weiss, Ruediger J.; Arora, Rohit; Gabl, Markus; Gruber, Johann; Jaschke, Werner; Klauser, Andrea S.

    2011-01-01

    Objectives: Acute or chronic pain at the pisiform may be due to tendinopathy of the flexor carpi ulnaris tendon (FCU) insertion, mechanical overuse, bony fractures, and osteoarthritis of the pisiform-triquetral joint. Enthesiopathy of the FCU at the pisiform might exhibit abnormalities assessable for sonographic characterization. This study aimed to determine the most relevant sonographic features of tendinopathy of the FCU insertion at the pisiform. Materials and methods: We retrospectively analyzed radiological findings of 9 patients admitted for high-frequency sonographic evaluation of a painful pisiform FCU insertion. The FCU insertion was assessed for active enthesiopathy in terms of tendon thickening and hyperemia, peritendinous effusion, peritendinous hyperemia, peritendinous soft tissue thickening, cystic fluid collections, erosive cortical irregularities, and osteoproliferative alterations at the pisiform. Results: Of all patients, 5 had inflammatory rheumatic disorders and the remainder had a painful pisiform FCU insertion related to overuse. While peritendinous effusion, pisiform erosive cortical irregularities, and peritendinous soft tissue thickening at the FCU insertion were exclusively found in rheumatic patients, active enthesiopathy of the FCU tendon, pisiform osteoproliferative alterations, and hyperemia of the peritendinous soft tissue were inconsistent and found in both groups. Cystic fluid collections from the pisiform-triquetral joint were only seen in patients with overuse. Conclusions: In this small case series of patients with pain at the pisiform FCU insertion, we could reveal several typical sonographic features for insertion tendinopathy. Further studies should prove if these sonographic features could impact on the management of patients with pain at the pisiform.

  18. Flexor pollicis longus tenosynovitis in patients with carpal tunnel syndrome.

    Science.gov (United States)

    Manfield, Laura; Thomas, Mark; Lee, Se Won

    2014-06-01

    Carpal tunnel syndrome is typically diagnosed from history and physical examination then confirmed with electrodiagnosis. Electrodiagnosis provides only limited anatomic information and evaluation of space-occupying lesions. The authors present two cases in which demonstrated flexor pollicis longus tenosynovitis coexistent with carpal tunnel syndrome was diagnosed with ultrasonography. Ultrasonography is an effective modality that enhances the investigation of diseases in the soft tissues of the wrist and the hand. It can be useful in directing specific treatment by increasing diagnostic accuracy.

  19. Accuracy of High-Resolution Ultrasonography in the Detection of Extensor Tendon Lacerations.

    Science.gov (United States)

    Dezfuli, Bobby; Taljanovic, Mihra S; Melville, David M; Krupinski, Elizabeth A; Sheppard, Joseph E

    2016-02-01

    Lacerations to the extensor mechanism are usually diagnosed clinically. Ultrasound (US) has been a growing diagnostic tool for tendon injuries since the 1990s. To date, there has been no publication establishing the accuracy and reliability of US in the evaluation of extensor mechanism lacerations in the hand. The purpose of this study is to determine the accuracy of US to detect extensor tendon injuries in the hand. Sixteen fingers and 4 thumbs in 4 fresh-frozen and thawed cadaveric hands were used. Sixty-eight 0.5-cm transverse skin lacerations were created. Twenty-seven extensor tendons were sharply transected. The remaining skin lacerations were used as sham dissection controls. One US technologist and one fellowship-trained musculoskeletal radiologist performed real-time dynamic US studies in and out of water bath. A second fellowship trained musculoskeletal radiologist subsequently reviewed the static US images. Dynamic and static US interpretation accuracy was assessed using dissection as "truth." All 27 extensor tendon lacerations and controls were identified correctly with dynamic imaging as either injury models that had a transected extensor tendon or sham controls with intact extensor tendons (sensitivity = 100%, specificity = 100%, positive predictive value = 1.0; all significantly greater than chance). Static imaging had a sensitivity of 85%, specificity of 89%, and accuracy of 88% (all significantly greater than chance). The results of the dynamic real time versus static US imaging were clearly different but did not reach statistical significance. Diagnostic US is a very accurate noninvasive study that can identify extensor mechanism injuries. Clinically suspected cases of acute extensor tendon injury scanned by high-frequency US can aid and/or confirm the diagnosis, with dynamic imaging providing added value compared to static. Ultrasonography, to aid in the diagnosis of extensor mechanism lacerations, can be successfully used in a reliable and

  20. Tissue engineering approaches to develop decellularized tendon matrices functionalized with progenitor cells cultured under undifferentiated and tenogenic conditions

    Directory of Open Access Journals (Sweden)

    Daniele D’Arrigo

    2017-11-01

    Full Text Available Tendon ruptures and retractions with an extensive tissue loss represent a major clinical problem and a great challenge in surgical reconstruction. Traditional approaches consist in autologous or allogeneic grafts, which still have some drawbacks. Hence, tissue engineering strategies aimed at developing functionalized tendon grafts. In this context, the use of xenogeneic tissues represents a promising perspective to obtain decellularized tendon grafts. This study is focused on the identification of suitable culture conditions for the generation of reseeded and functional decellularized constructs to be used as tendon grafts. Equine superficial digital flexor tendons were decellularized, reseeded with mesenchymal stem cells (MSCs from bone marrow and statically cultured in two different culture media to maintain undifferentiated cells (U-MSCs or to induce a terminal tenogenic differentiation (T-MSCs for 24 hours, 7 and 14 days. Cell viability, proliferation, morphology as well as matrix deposition and type I and III collagen production were assessed by means of histological, immunohistochemical and semi-quantitative analyses. Results showed that cell viability was not affected by any culture conditions and active proliferation was maintained 14 days after reseeding. However, seeded MSCs were not able to penetrate within the dense matrix of the decellularized tendons. Nevertheless, U-MSCs synthesized a greater amount of extracellular matrix rich in type I collagen compared to T-MSCs. In spite of the inability to deeply colonize the decellularized matrix in vitro, reseeding tendon matrices with U-MSCs could represent a suitable method for the functionalization of biological constructs, considering also any potential chemoattractant capability of the newly deposed extracellular matrix to recruit resident cells. This bioengineering approach can be exploited to produce functionalized tendon constructs for the substitution of large tendon defects.

  1. Structural Integration and Control of Peerless Human-like Prosthetic Hand

    Science.gov (United States)

    Dave, Ankit; Muthu, P.; Karthikraj, V.; Latha, S.

    2018-04-01

    Limb damage can create severe disturbance in movement and operative abilities wherein the prosthetic rehabilitation has the potential to replace function and enhance the quality of life. This paper presents a humanlike prosthetic hand using such unique design concept of hand model using artificial bones, ligaments, and tendons controlled using Arduino. Amongst various platforms available, Arduino is known for its adaptability, adoration and low cost. The design of prosthetic hand has a unique structure with all carpal, metacarpal, and phalanges which are bones of the hand. These bones are attached to each other following the pattern of human hand using the polymeric rubber as a functioning ligament. Furthermore, this structure of finger is driven by tendons attached to all fingers and passes through the ligaments working as pulley resulting in more degrees of freedom. The motor can twitch the tendons to achieve the action of fingers. Thus the servos, controlled by an Arduino, are used to regulate the movement mechanism of the prosthetic hand.

  2. Tendon surveillance requirements - average tendon force

    International Nuclear Information System (INIS)

    Fulton, J.F.

    1982-01-01

    Proposed Rev. 3 to USNRC Reg. Guide 1.35 discusses the need for comparing, for individual tendons, the measured and predicted lift-off forces. Such a comparison is intended to detect any abnormal tendon force loss which might occur. Recognizing that there are uncertainties in the prediction of tendon losses, proposed Guide 1.35.1 has allowed specific tolerances on the fundamental losses. Thus, the lift-off force acceptance criteria for individual tendons appearing in Reg. Guide 1.35, Proposed Rev. 3, is stated relative to a lower bound predicted tendon force, which is obtained using the 'plus' tolerances on the fundamental losses. There is an additional acceptance criterion for the lift-off forces which is not specifically addressed in these two Reg. Guides; however, it is included in a proposed Subsection IWX to ASME Code Section XI. This criterion is based on the overriding requirement that the magnitude of prestress in the containment structure be sufficeint to meet the minimum prestress design requirements. This design requirement can be expressed as an average tendon force for each group of vertical hoop, or dome tendons. For the purpose of comparing the actual tendon forces with the required average tendon force, the lift-off forces measured for a sample of tendons within each group can be averaged to construct the average force for the entire group. However, the individual lift-off forces must be 'corrected' (normalized) prior to obtaining the sample average. This paper derives the correction factor to be used for this purpose. (orig./RW)

  3. Osteomyelitis of the proximal sesamoid bone in a horse - a case report

    International Nuclear Information System (INIS)

    Kofler, J.

    1994-01-01

    Suppurative osteomyelitis of the lateral proximal sesamoid bone and chronic septic tenosynovitis of the digital flexor tendon sheath of the right hind limb was diagnosed in a 8 year old warmblood mare. Three months earlier the horse had received a puncture wound in the plantar fetlock region, penetrating the plantar annular ligament, tendon sheath and intersesamoidian ligament up to the plantaro-axial surface of the lateral sesamoid bone. The clinical, radiographic and ultrasonographic findings are described. The horse showed grade 2 / 4 right hindlimb lameness, marked thickening of the entire digital flexor tendon sheath area as well as the puncture wound in the middle of the annular ligament region. Radiographs revealed a 10 x 12 mm centro-axial, circular translucent lesion and marked bony proliferation on the abaxial and plantar margins of the lateral proximal sesamoid. Adhesions and marked anechoic areas between the plantar septum of the tendon sheath and the superficial flexor tendon, a thickening of the plantar annular ligament and structural alterations of the deep flexor tendon were demonstrated by sonography. Due to these severe findings a very poor prognosis was given and therefore surgery was not recommended. The horse was euthanized 4 months later as a result of further deterioration. Additional clinical, radiographic and sonographic findings as well as post mortem findings are mentioned. Gross pathology showed a fibrino-purulent tenosynovitis of the digital flexor tendon sheath and tendinitis of both flexor tendons, as well as a fistulous lesion of the intersesamoidian ligament over the lateral proximal sesamoid bone. The patho-histologic examination revealed focal suppurative osteomyelitis of the lateral sesamoid bone with necrotic bone tissue in the osteolytic area and accumulated neutrophils and macrophages [de

  4. Open dislocation of the proximal interphalangeal joint of the little finger subsequent to chronic radial collateral ligament injury: a case report of primary ligament reconstruction with a half-slip of the flexor digitorum superficialis: Case Report.

    Science.gov (United States)

    Wada, Kazuma; Hibino, Naohito; Kondo, Kenji; Yoshioka, Shinji; Terai, Tomoya; Henmi, Tatsuhiko; Sairyo, Koichi

    2015-01-01

    Open dislocation of the proximal interphalangeal (PIP) joint is relatively rare. We report a case of a 32-year-old man who had open dislocation of the PIP joint of the little finger while playing American football. He had a history of chronic radial collateral ligament injury. We reconstructed the radial collateral ligament with a half-slip of the flexor digitorum superficialis tendon.

  5. Synovial hemangioma in an adult horse.

    Science.gov (United States)

    Holzhausen, Lars; Nowak, Michael; Junginger, Johannes; Puff, Christina

    2012-03-01

    A 15-year-old gelding presented with a progressive lameness of the left forelimb of 2.5 months duration. Clinically, a dilation of the deep flexor tendon sheath with a firm elastic consistency and a pronounced tenderness was noted. Ultrasonically, a marked swelling of the flexor tendon sheath with an irregular density of the mesotendineum was observed. The white, firm material forming a nodular distension of the flexor tendon sheath with a diameter of approximately 1 cm was excised and sent for histopathological examination. Biopsies of the deep flexor tendon and corresponding tendon sheath were sent for histopathological evaluation. Histologically, the mass consisted of clefts and numerous anastomosing vascular channels extending between the collagen fibers of the deep flexor tendon. These capillary-like spaces were lined by neoplastic cells that were flattened to polygonal and contained few erythrocytes. There was 0 to 1 mitotic figure per 10 high power fields (400×). Immunohistochemically, the neoplastic cells stained positive for vimentin and factor VIII-related antigen. Adjacent to the neoplastic endothelial cells located pericytes expressed α-smooth muscle actin antigen. Based on the histopathological and immunohistochemical features, synovial hemangioma was diagnosed. One year after surgery, the horse has shown no lameness.

  6. Bone and muscular anatomy of the forearm and hand in Tapirus terrestris (Perissodactyla, Tapiridae

    Directory of Open Access Journals (Sweden)

    Saulo Gonçalves Pereira

    2017-05-01

    Full Text Available In Brazil, there are two species of tapirs, the largest land mammals in Brazil, which belong to the order Perissodactyla, as do horses. Our aim was to describe the bone and muscular anatomy of the forearm and hand in T. terrestris and to propose adaptive functions. We used five anatomical specimens donated from a breeder to the Laboratory for Teaching and Research on Wild Animals of the Federal University of Uberlandia after death with no trauma. The bones were analyzed, the muscles dissected, and both described. The bones of the forearm and hand of the tapir are the ulna, radius, Os. metacarpalia, Os. carpi, phalanx and Os. sesamoideum. The muscles are M. extensor carpi radialis, M. ulnaris lateralis; M. flexor carpi radialis; M. extensor radialis communis; M. extensor digitorum longus II, III, IV and V, M. extensor digitorum lateralis; M. extensor digitorum; M. abductor longus; M. flexor digiti superficialis; M. flexor digitalis; M. flexor carpi ulnaris; M. flexor carpi obliquus; and M. interossei and M. lumbricales. Characteristics of bone and muscle structure are adapted to the development of the animal’s niche.

  7. Multi-functional electrospun antibacterial core-shell nanofibrous membranes for prolonged prevention of post-surgical tendon adhesion and inflammation.

    Science.gov (United States)

    Shalumon, K T; Sheu, Chialin; Chen, Chih-Hao; Chen, Shih-Heng; Jose, Gils; Kuo, Chang-Yi; Chen, Jyh-Ping

    2018-05-01

    The possibility of endowing an electrospun anti-adhesive barrier membrane with multi-functionality, such as lubrication, prevention of fibroblast attachment and anti-infection and anti-inflammation properties, is highly desirable for the management of post-surgical tendon adhesion. To this end, we fabricated core-shell nanofibrous membranes (CSNMs) with embedded silver nanoparticles (Ag NPs) in the poly(ethylene glycol) (PEG)/poly(caprolactone) (PCL) shell and hyaluronic acid (HA)/ibuprofen in the core. HA imparted a lubrication effect for smooth tendon gliding and reduced fibroblast attachment, while Ag NPs and ibuprofen functioned as anti-infection and anti-inflammation agents, respectively. CSNMs with a PEG/PCL/Ag shell (PPA) and HA core containing 0% (H/PPA), 10% (HI10/PPA), 30% (HI30/PPA) and 50% (HI50/PPA) ibuprofen were fabricated through co-axial electrospinning and assessed through microscopic, spectroscopic, thermal, mechanical and drug release analyses. Considering nutrient passage through the barrier, the microporous CSNMs exerted the same barrier effect but drastically increased the mass transfer coefficients of bovine serum albumin compared with the commercial anti-adhesive membrane SurgiWrap®. Cell attachment/focal adhesion formation of fibroblasts revealed effective reduction of initial cell attachment on the CSNM surface with minimum cytotoxicity (except HI50/PPA). The anti-bacterial effect against both Gram-negative and Gram-positive bacteria was verified to be due to the Ag NPs in the membranes. In vivo studies using H/PPA and HI30/PPA CSNMs and SurgiWrap® in a rabbit flexor tendon rupture model demonstrated the improved efficacy of HI30/PPA CSNMs in reducing inflammation and tendon adhesion formation based on gross observation, histological analysis and functional assays. We conclude that HI30/PPA CSNMs can act as a multifunctional barrier membrane to prevent peritendinous adhesion after tendon surgery. A multi-functional anti-adhesion barrier

  8. The cross-sectional area of the superficial digital flexor tendon of trained and untrained Thoroughbred racehorses Área transversal do tendão flexor digital superficial de cavalos Puro Sangue Inglês de corrida em treinamento e sem treinamento

    Directory of Open Access Journals (Sweden)

    Ana Guiomar Matos Santiago Reis

    2010-08-01

    Full Text Available Twenty Thoroughbred racehorses were ultrasonographically evaluated to determine the relation between normal values of the cross-sectional area (CSA of the right and left forelimbs superficial digital flexor tendons (SDFT in the metacarpal region for trained and untrained Thoroughbreds racehorses. Ultrasonography revealed that CSA at 26cm distal to the accessory carpal bone is larger than other proximal levels, for either left or right forelimbs. In addition, the CSA at 2, 4, 6, 8, 10, 12 and 14cm distal to the accessory carpal bone of the left forelimb are larger (P0.05 between left and right forelimb for CSA of the SDFT, at any level, for either trained or untrained horses, and there was no significant difference between untrained or trained horses for the CSA of right forelimb. In conclusion, the CSA of the left forelimb SDFT for horses that had been in continuous race training remains larger when they were trained anticlockwise, contrary to horses that had not been training for more than one year.Vinte cavalos da raça Puro Sangue Inglês de corrida foram submetidos a exame ultrassonográfico, com o intuito de determinar a relação entre os valores normais da área do tendão flexor digital superficial (TFDS na região metacarpiana dos membros torácicos direito e esquerdo, em cavalos com e sem treinamento. O exame ultrassonográfico revelou que a área do tendão 26cm distal ao osso acessório do carpo é maior em comparação com as alturas proximais, tanto nos membros torácicos esquerdos, como nos membros torácicos direitos. Além disso, a área do TFDS nas alturas 2, 4, 6, 8, 10, 12 e 14cm, no membro torácico esquerdo, é maior (P0,05 nas áreas do TFDS entre os membros torácicos direito e esquerdo, tanto para os animais em treinamento, como para os animais sem treinamento. Também não foi encontrada diferença significativa em comparação com o membro direito dos cavalos em treinamento e sem treinamento. Conclui-se que os cavalos

  9. Iliopsoas Tendon Reformation after Psoas Tendon Release

    Directory of Open Access Journals (Sweden)

    K. Garala

    2013-01-01

    Full Text Available Internal snapping hip syndrome, or psoas tendonitis, is a recognised cause of nonarthritic hip pain. The majority of patients are treated conservatively; however, occasionally patients require surgical intervention. The two surgical options for iliopsoas tendinopathy are step lengthening of the iliopsoas tendon or releasing the tendon at the lesser trochanter. Although unusual, refractory snapping usually occurs soon after tenotomy. We report a case of a 47-year-old active female with internal snapping and pain following an open psoas tenotomy. Postoperatively she was symptom free for 13 years. An MRI arthrogram revealed reformation of a pseudo iliopsoas tendon reinserting into the lesser trochanter. The pain and snapping resolved after repeat iliopsoas tendon release. Reformation of tendons is an uncommon sequela of tenotomies. However the lack of long-term studies makes it difficult to calculate prevalence rates. Tendon reformation should be included in the differential diagnosis of failed tenotomy procedures after a period of symptom relief.

  10. Applied Joint-Space Torque and Stiffness Control of Tendon-Driven Fingers

    Science.gov (United States)

    Abdallah, Muhammad E.; Platt, Robert, Jr.; Wampler, Charles W.; Hargrave, Brian

    2010-01-01

    Existing tendon-driven fingers have applied force control through independent tension controllers on each tendon, i.e. in the tendon-space. The coupled kinematics of the tendons, however, cause such controllers to exhibit a transient coupling in their response. This problem can be resolved by alternatively framing the controllers in the joint-space of the manipulator. This work presents a joint-space torque control law that demonstrates both a decoupled and significantly faster response than an equivalent tendon-space formulation. The law also demonstrates greater speed and robustness than comparable PI controllers. In addition, a tension distribution algorithm is presented here to allocate forces from the joints to the tendons. It allocates the tensions so that they satisfy both an upper and lower bound, and it does so without requiring linear programming or open-ended iterations. The control law and tension distribution algorithm are implemented on the robotic hand of Robonaut-2.

  11. Irrigación arterial del músculo interóseo y del ligamento accesorio del músculo flexor digital profundo en la mano del caballo Arterial blood supply to the interosseus muscle and accessory ligament of the deep digital flexor tendon in the horse hand

    OpenAIRE

    J. NATALI; R.M. MOINE; M.S. GIGENA; A.M. GALÁN; E. MARTÍN

    1999-01-01

    El objetivo de este trabajo es el estudio del origen y distribución de las ramas arteriales al músculo interóseo y al ligamento accesorio del músculo flexor digital profundo de la mano del caballo. Se disecaron 20 manos a las que les fue inyectada la arteria mediana con látex coloreado. Las ramas arteriales entran al músculo interóseo por la cara dorsal y palmar del cuerpo y por sus bordes medial y lateral. Cada tendón de inserción del músculo interóseo recibió importantes ramas arteriales po...

  12. Achilles tendon injuries in elite athletes: lessons in pathophysiology from their equine counterparts.

    Science.gov (United States)

    Patterson-Kane, Janet C; Rich, Tina

    2014-01-01

    Superficial digital flexor tendon (SDFT) injury in equine athletes is one of the most well-accepted, scientifically supported companion animal models of human disease (i.e., exercise-induced Achilles tendon [AT] injury). The SDFT and AT are functionally and clinically equivalent (and important) energy-storing structures for which no equally appropriate rodent, rabbit, or other analogues exist. Access to equine tissues has facilitated significant advances in knowledge of tendon maturation and aging, determination of specific exercise effects (including early life), and definition of some of the earliest stages of subclinical pathology. Access to human surgical biopsies has provided complementary information on more advanced phases of disease. Importantly, equine SDFT injuries are only a model for acute ruptures in athletes, not the entire spectrum of human tendonopathy (including chronic tendon pain). In both, pathology begins with a potentially prolonged phase of accumulation of (subclinical) microdamage. Recent work has revealed remarkably similar genetic risk factors, including further evidence that tenocyte dysfunction plays an active role. Mice are convenient but not necessarily accurate models for multiple diseases, particularly at the cellular level. Mechanistic studies, including tendon cell responses to combinations of exercise-associated stresses, require a more thorough investigation of cross-species conservation of key stress pathway auditors. Molecular evidence has provided some context for the poor performance of mouse models; equines may provide better systems at this level. The use of horses may be additionally justifiable based on comparable species longevity, lifestyle factors, and selection pressure by similar infectious agents (e.g., herpesviruses) on general cell stress pathway evolution. © The Author 2014. Published by Oxford University Press on behalf of the Institute for Laboratory Animal Research. All rights reserved. For permissions

  13. Incidence and morphology of accessory heads of flexor pollicis longus and flexor digitorum profundus (Gantzer's muscles)

    Science.gov (United States)

    JONES, M.; ABRAHAMS, P. H.; SAÑUDO, J. R.; CAMPILLO, M.

    1997-01-01

    In 1813 Gantzer described 2 accessory muscles in the human forearm which bear his name (Wood, 1868; Macalister, 1875; Testut, 1884; Le Double, 1897). The more frequent of the 2 accessory muscles or ‘accessorius ad pollicem’ was found to arise from the coronoid process of the ulna, coursing distally to attach into the flexor pollicis longus muscle (flexor pollicis longus accessory head, FPLah). The less frequently observed or ‘accessorius ad flexorem profundum digitorum’ was again found to arise from the coronoid process and course to join into the flexor digitorum profundus (flexor digitorum profundus accessory head, FDPah). Since their initial description, they have been examined in further detail by a number of authors (Wood, 1868; Macalister, 1875; Le Double, 1897; Dykes & Anson, 1944; Mangini, 1960; Malhotra et al. 1982; Dellon & McKinnon, 1987; Kida, 1988). These studies, most of them focusing on the FPLah, all show different results of prevalence, origin, insertion, relations and nerve supply. We undertook this study with the aim of providing a more accurate account of the detailed morphology of both accessory muscles because of the above-mentioned inconsistent anatomical descriptions and the lack of information as to important aspects such as vascular supply, morphology (shape and length) and the coexistence of both accessory heads. PMID:9419002

  14. Bone and muscular anatomy of the forearm and hand in Tapirus terrestris (Perissodactyla, Tapiridae

    Directory of Open Access Journals (Sweden)

    Saulo Gonçalves Pereira

    2017-05-01

    Full Text Available http://dx.doi.org/10.5007/2175-7925.2017v30n2p35 In Brazil, there are two species of tapirs, the largest land mammals in Brazil, which belong to the order Perissodactyla, as do horses. Our aim was to describe the bone and muscular anatomy of the forearm and hand in T. terrestris and to propose adaptive functions. We used five anatomical specimens donated from a breeder to the Laboratory for Teaching and Research on Wild Animals of the Federal University of Uberlandia after death with no trauma. The bones were analyzed, the muscles dissected, and both described. The bones of the forearm and hand of the tapir are the ulna, radius, Os. metacarpalia, Os. carpi, phalanx and Os. sesamoideum. The muscles are M. extensor carpi radialis, M. ulnaris lateralis; M. flexor carpi radialis; M. extensor radialis communis; M. extensor digitorum longus II, III, IV and V, M. extensor digitorum lateralis; M. extensor digitorum; M. abductor longus; M. flexor digiti superficialis; M. flexor digitalis; M. flexor carpi ulnaris; M. flexor carpi obliquus; and M. interossei and M. lumbricales. Characteristics of bone and muscle structure are adapted to the development of the animal’s niche.

  15. Risk factors for hand-wrist disorders in repetitive work

    DEFF Research Database (Denmark)

    Thomsen, J. F.; Mikkelsen, S.; Andersen, JH

    2007-01-01

    OBJECTIVES: To identify the risk of hand-wrist disorders related to repetitive movements, use of hand force and wrist position in repetitive monotonous work. METHODS: Using questionnaires and physical examinations, the prevalence and incidence of hand-wrist pain and possible extensor tendonitis...... (wrist pain and palpation tenderness) were determined in 3123 employees in 19 industrial settings. With the use of questionnaires and video recordings of homogenous work tasks number of wrist movements, hand force requirements and wrist position were analysed as risk factors for hand-wrist disorders......, controlling for potential personal and psychosocial confounders. All participants were re-examined three times during a follow-up period of three years. RESULTS: Force but not repetition and position was related to hand-wrist pain and possible tendonitis in the baseline analyses showing an exposure...

  16. Arthroscopic assisted tendon reconstruction for triangular fibrocartilage complex irreparable tears.

    Science.gov (United States)

    Luchetti, R; Atzei, A

    2017-05-01

    We report our 11-year experience of performing arthroscopically assisted triangular fibrocartilage complex reconstruction in the treatment of chronic distal radio-ulnar joint instability resulting from irreparable triangular fibrocartilage complex injuries. Eleven patients were treated. Three skin incisions were made in order to create radial and ulna tunnels for passage of the tendon graft, which is used to reconstruct the dorsal and palmar radio-ulnar ligaments, under fluoroscopic and arthroscopic guidance. At a mean follow-up of 68 months all but one had a stable distal radio-ulnar joint. Pain and grip strength, Mayo wrist score, Disability of the Arm Hand and Shoulder and patient-rated wrist and hand evaluation scores improved. The ranges of forearm rotation remained largely unchanged. Complications included an early tendon graft tear, two late-onset graft ruptures, one ulna styloid fracture during surgery and persistent wrist discomfort during forearm rotation requiring tendon graft revision in one case. An arthroscopic assisted approach for triangular fibrocartilage complex reconstruction appears safe and produces comparable results with the open technique. IV.

  17. [Development of Achilles tendon rupture in skiing].

    Science.gov (United States)

    Suckert, K; Benedetto, K P; Vogel, A

    1983-06-01

    This is an analysis of decline of rupture of the Achilles tendon in skiing while there is a steady increase of skiing injuries. Three groups, equipped with three different types of ski boots were observed once on a plane slope on the other hand on a bump track. The simultaneous size of angle of knee and ankle was measured by telemetry. The high plastic ski boot, which obstructs the ankle forward and lateral is apart from the rise of heel in the boot, the safety binding and the new skiing style the main reason for decline of rupture of the Achilles tendon in skiing.

  18. Macrophage sub-populations and the lipoxin A4 receptor implicate active inflammation during equine tendon repair.

    Directory of Open Access Journals (Sweden)

    Stephanie Georgina Dakin

    Full Text Available Macrophages (Mφ orchestrate inflammatory and reparatory processes in injured connective tissues but their role during different phases of tendon healing is not known. We investigated the contribution of different Mφ subsets in an equine model of naturally occurring tendon injury. Post mortem tissues were harvested from normal (uninjured, sub-acute (3-6 weeks post injury and chronically injured (>3 months post injury superficial digital flexor tendons. To determine if inflammation was present in injured tendons, Mφ sub-populations were quantified based on surface antigen expression of CD172a (pan Mφ, CD14(highCD206(low (pro-inflammatory M1Mφ, and CD206(high (anti-inflammatory M2Mφ to assess potential polarised phenotypes. In addition, the Lipoxin A(4 receptor (FPR2/ALX was used as marker for resolving inflammation. Normal tendons were negative for both Mφ and FPR2/ALX. In contrast, M1Mφ predominated in sub-acute injury, whereas a potential phenotype-switch to M2Mφ polarity was seen in chronic injury. Furthermore, FPR2/ALX expression by tenocytes was significantly upregulated in sub-acute but not chronic injury. Expression of the FPR2/ALX ligand Annexin A1 was also significantly increased in sub-acute and chronic injuries in contrast to low level expression in normal tendons. The combination of reduced FPR2/ALX expression and persistence of the M2Mφ phenotype in chronic injury suggests a potential mechanism for incomplete resolution of inflammation after tendon injury. To investigate the effect of pro-inflammatory mediators on lipoxin A(4 (LXA(4 production and FPR2/ALX expression in vitro, normal tendon explants were stimulated with interleukin-1 beta and prostaglandin E(2. Stimulation with either mediator induced LXA(4 release and maximal upregulation of FPR2/ALX expression after 72 hours. Taken together, our data suggests that although tenocytes are capable of mounting a protective mechanism to counteract inflammatory stimuli, this

  19. A compliant underactuated hand with suction flow for underwater mobile manipulation

    KAUST Repository

    Stuart, Hannah S.

    2014-05-01

    © 2014 IEEE. Fingertip suction is investigated using a compliant, underactuated, tendon-driven hand designed for underwater mobile manipulation. Tendon routing and joint stiffnesses are designed to provide ease of closure while maintaining finger rigidity, allowing the hand to pinch small objects, as well as secure large objects, without diminishing strength. While the hand is designed to grasp a range of objects, the addition of light suction flow to the fingertips is especially effective for small, low-friction (slippery) objects. Numerical simulations confirm that changing suction parameters can increase the object acquisition region, providing guidelines for future versions of the hand.

  20. A compliant underactuated hand with suction flow for underwater mobile manipulation

    KAUST Repository

    Stuart, Hannah S.; Wang, Shiquan; Gardineer, Bayard; Christensen, David L.; Aukes, Daniel M.; Cutkosky, Mark

    2014-01-01

    © 2014 IEEE. Fingertip suction is investigated using a compliant, underactuated, tendon-driven hand designed for underwater mobile manipulation. Tendon routing and joint stiffnesses are designed to provide ease of closure while maintaining finger rigidity, allowing the hand to pinch small objects, as well as secure large objects, without diminishing strength. While the hand is designed to grasp a range of objects, the addition of light suction flow to the fingertips is especially effective for small, low-friction (slippery) objects. Numerical simulations confirm that changing suction parameters can increase the object acquisition region, providing guidelines for future versions of the hand.

  1. Effects of acute static, ballistic, and PNF stretching exercise on the muscle and tendon tissue properties.

    Science.gov (United States)

    Konrad, A; Stafilidis, S; Tilp, M

    2017-10-01

    The purpose of this study was to investigate the influence of a single static, ballistic, or proprioceptive neuromuscular facilitation (PNF) stretching exercise on the various muscle-tendon parameters of the lower leg and to detect possible differences in the effects between the methods. Volunteers (n = 122) were randomly divided into static, ballistic, and PNF stretching groups and a control group. Before and after the 4 × 30 s stretching intervention, we determined the maximum dorsiflexion range of motion (RoM) with the corresponding fascicle length and pennation angle of the gastrocnemius medialis. Passive resistive torque (PRT) and maximum voluntary contraction (MVC) were measured with a dynamometer. Observation of muscle-tendon junction (MTJ) displacement with ultrasound allowed us to determine the length changes in the tendon and muscle, respectively, and hence to calculate stiffness. Although RoM increased (static: +4.3%, ballistic: +4.5%, PNF: +3.5%), PRT (static: -11.4%, ballistic: -11.5%, PNF: -13,7%), muscle stiffness (static: -13.1%, ballistic: -20.3%, PNF: -20.2%), and muscle-tendon stiffness (static: -11.3%, ballistic: -10.5%, PNF: -13.7%) decreased significantly in all the stretching groups. Only in the PNF stretching group, the pennation angle in the stretched position (-4.2%) and plantar flexor MVC (-4.6%) decreased significantly. Multivariate analysis showed no clinically relevant difference between the stretching groups. The increase in RoM and the decrease in PRT and muscle-tendon stiffness could be explained by more compliant muscle tissue following a single static, ballistic, or PNF stretching exercise. © 2017 The Authors Scandinavian Journal of Medicine & Science In Sports Published by John Wiley & Sons Ltd.

  2. Golf Injuries to the Hand, Wrist, or Elbow

    Science.gov (United States)

    ... Therapist? Media Find a Hand Surgeon Home Anatomy Golf Injuries to the Hand, Wrist or Elbow Email ... enjoyment of the game injury free. Types of Golf Injuries Golf injuries can include tendonitis, sprains or ...

  3. Effects of exercise on tenocyte cellularity and tenocyte nuclear morphology in immature and mature equine digital tendons.

    Science.gov (United States)

    Stanley, R L; Goodship, A E; Edwards, B; Firth, E C; Patterson-Kane, J C

    2008-03-01

    The injury-prone, energy-storing equine superficial digital flexor tendon (SDFT) of the mature performance horse has a limited ability to respond to exercise in contrast with the noninjury-prone, anatomically opposing common digital extensor tendon (CDET). Previous studies have indicated low levels of cellular activity in the mature SDFT, but in foal tendons the tenocytes may still have the ability to adapt positively to increased exercise. To measure tenocyte densities and types in histological sections from the SDFT and CDET of horses from controlled long-term, short-term and foal exercise studies. Specimens were collected from mid-metacarpal segments of the CDET and SDFT for each horse and processed for histology; central and peripheral regions of the SDFT cross-section were analysed separately (SDFTc, SDFTp). Tenocyte nuclei were counted in a total area of 1.59 mm(2) for each tendon region in each horse. Each nucleus was classified as type 1 (elongate and thin), type 2 (ovoid and plump) or type 3 (chondrocyte-like); type 1 cells are proposed to be less synthetically active than type 2 cells. No significant differences were noted between exercise and control groups in any of the studies, with the exception of an exercise-related reduction in the proportion of type 1 tenocytes for all tendons combined in the long-term study. There were tendon- and site-specific differences in tenocyte densities and proportions of type 1 and 2 cells in all 3 studies. There was no indication that exercise increased tenocyte density or proportions of the (theoretically) more active type 2 cells in immature horses (short-term and foal studies), perhaps because the training regimens did not achieve certain threshold strain levels. In the foal study these findings can still be interpreted positively as evidence that the training regimen did not induce subclinical damage.

  4. Lengthening osteotomy of the calcaneus and flexor digitorum longus tendon transfer in flexible flatfoot deformity improves talo-1st metatarsal-Index, clinical outcome and pedographic parameter.

    Science.gov (United States)

    Richter, Martinus; Zech, Stefan

    2013-03-01

    Lengthening osteotomy of the calcaneus (LO) and flexor digitorum longus tendon (FDL) transfer to the navicular is one option for the treatment of flexible flatfoot deformity (FD). The aim of the study was to analyse the amount of correction and clinical outcome including pedographic assessment. In a prospective consecutive non-controlled clinical followup study, all patients with FD that were treated with LO and FDL from September 1st 2006 to August 31st, 2009 were included. Assessment was performed before surgery and at 2-year-followup including clinical examination (with staging of posterior tibialis insufficiency) weight bearing radiographs (Talo-1st metatarsal angles (TMT)), pedography (increased midfoot contact area and force) and Visual Analogue Scale Foot and Ankle (VAS FA). 112 feet in 102 patients were analysed (age, 57.6 (13-82), 42% male). In 12 feet (9%) wound healing delay without further surgical measures was registered. All patients achieved full weight bearing during the 7th postoperative week. Until followup, revision surgery was done in 3 patients (fusion calcaneocuboid joint (n=2), correction triple arthrodesis (n=1)). 101 feet (90%) completed 2-year-followup. TMT dorsoplantar/lateral/Index and VAS FA scores were increased, and posterior tibialis insufficiency stage, pedographic midfoot contact area and force percentage were decreased (each pstage of posterior tibialis insufficiency, TMT angles and Index, pedographic midfoot contact area and force percentage, VAS FA) were improved 2 years after LO and FDL transfer to the navicular in FD. The complication rate was low. This method allows safe and predictable correction. Copyright © 2012 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  5. Distal finger replantation.

    Science.gov (United States)

    Scheker, Luis R; Becker, Giles W

    2011-03-01

    Reconstruction of the fingertip distal to the flexor tendon insertion by replantation remains controversial and technically challenging, but the anatomy of the fingertip has been well described and provides help in surgical planning. The open-book surgical technique is described with potential complications and is illustrated with clinical cases. Copyright © 2011 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  6. Presence of Multiple Tendinous Insertions of Palmaris Longus: A ...

    African Journals Online (AJOL)

    Case Details: We report here a unique case of palmaris longus presenting variation distally as its tendon divides to gain multiple attachments with the fascia covering the abductor pollicis brevis, flexor retinaculum and the tendon of flexor carpi ulnaris. In addition, it also continues as palmar aponeurosis as its normal course.

  7. Potential Relationship between Passive Plantar Flexor Stiffness and Running Performance.

    Science.gov (United States)

    Ueno, Hiromasa; Suga, Tadashi; Takao, Kenji; Tanaka, Takahiro; Misaki, Jun; Miyake, Yuto; Nagano, Akinori; Isaka, Tadao

    2018-02-01

    The present study aimed to determine the relationship between passive stiffness of the plantar flexors and running performance in endurance runners. Forty-eight well-trained male endurance runners and 24 untrained male control subjects participated in this study. Plantar flexor stiffness during passive dorsiflexion was calculated from the slope of the linear portion of the torque-angle curve. Of the endurance runners included in the present study, running economy in 28 endurance runners was evaluated by measuring energy cost during three 4-min trials (14, 16, and 18 km/h) of submaximal treadmill running. Passive stiffness of the plantar flexors was significantly higher in endurance runners than in untrained subjects. Moreover, passive plantar flexor stiffness in endurance runners was significantly correlated with a personal best 5000-m race time. Furthermore, passive plantar flexor stiffness in endurance runners was significantly correlated with energy cost during submaximal running at 16 km/h and 18 km/h, and a trend towards such significance was observed at 14 km/h. The present findings suggest that stiffer plantar flexors may help achieve better running performance, with greater running economy, in endurance runners. Therefore, in the clinical setting, passive stiffness of the plantar flexors may be a potential parameter for assessing running performance. © Georg Thieme Verlag KG Stuttgart · New York.

  8. Hip flexor strain -- aftercare

    Science.gov (United States)

    ... flexors. Runners, people who do martial arts, and football, soccer, and hockey players are more likely to ... herein should not be used during any medical emergency or for the diagnosis or treatment of any ...

  9. EMG Analysis and Sagittal Plane Kinematics of the Two-Handed and Single-Handed Kettlebell Swing: A Descriptive Study.

    Science.gov (United States)

    Van Gelder, Leonard H; Hoogenboom, Barbara J; Alonzo, Bryan; Briggs, Dayna; Hatzel, Brian

    2015-11-01

    Kettlebell (KB) swing exercises have been proposed as a possible method to improve hip and spinal motor control as well as improve power, strength, and endurance. To describe electromyographic (EMG) and sagittal plane kinematics during two KB exercises: the two-handed KB swing (THKS) and the single-handed KB swing (SHKS). In addition, the authors sought to investigate whether or not hip flexor length related to the muscular activity or the kinematics of the exercise. Twenty-three healthy college age subjects participated in this study. Demographic information and passive hip flexor length were recorded for each subject. A maximum voluntary isometric contraction (MVIC) of bilateral gluteus maximus (GMAX), gluteus medius (GMED), and biceps femoris (BF) muscles was recorded. EMG activity and sagittal plane video was recorded during both the THKS and SHKS in a randomized order. Normalized muscular activation of the three studied muscles was calculated from EMG data. During both SHKS and THKS, the average percent of peak MVIC for GMAX was 75.02% ± 55.38, GMED 55.47% ± 26.33, and BF 78.95% ± 53.29. Comparisons of the mean time to peak activation (TTP) for each muscle showed that the biceps femoris was the first muscle to activate during the swings. Statistically significant (p < .05), moderately positive correlations (r = .483 and .417) were found between passive hip flexor length and % MVIC for the GMax during the SHKS and THKS, respectively. The THKS and SHKS provide sufficient muscular recruitment for strengthening of all of the muscles explored. This is the first study to show significant correlations between passive hip flexor length and muscular activation of hip extensors, particularly the GMax. Finally, the BF consistently reached peak activity before the GMax and GMed during the SHKS. Level 3.

  10. Spontaneous Extensor Tendon Rupture in the Rheumatoid Wrist: Risk Factors and Preventive Role of Extended Tenosynovectomy.

    Science.gov (United States)

    Hsueh, Jung-Hua; Liu, Wen-Chung; Yang, Kuo-Chung; Hsu, Kuei-Chang; Lin, Cheng-Ta; Chen, Lee-Wei

    2016-03-01

    Spontaneous extensor tendon rupture is often seen in rheumatoid arthritis (RA) patients, but the risk factors are not clearly defined. We therefore collected the data of RA patients with previous extensor tendon rupture and those with tenosynovitis and analyzed the relationship between extended tenosynovectomy and spontaneous extensor tendon rupture. We retrospectively reviewed 17 spontaneous extensor tendon rupture episodes in 15 RA patients and 14 tenosynovitis episodes that required tenosynovectomy in 12 RA patients from 1997 to 2013. Correlations between the incidence of tendon rupture, X-ray findings, and clinical findings in the affected wrists before tendon rupture were analyzed statistically using the test for proportion. The following parameters were significantly correlated with spontaneous extensor tendon rupture: disease duration longer than 8 years, persistent tenosynovitis longer than 1 year duration, and Larsen grade greater than 4 (P = 0.02, 0.03, and 0.01, respectively). Dislocation of the distal end of the ulna, carpal collapse, and the scallop sign on X-ray contributed to a higher spontaneous extensor tendon rupture rate among RA patients (P = 0.01, 0.05, and 0.03, respectively). Extended tenosynovectomy was performed on 14 wrists in 12 RA patients with persistent tenosynovitis longer than 6 months, and Larsen grade did not deteriorate in this group compared with those who did not undergo the surgery. No spontaneous extensor tendon rupture occurred following the surgery. Risk factors of spontaneous extensor tendon rupture included disease duration longer than 8 years, persistent tenosynovitis longer than 1 year, and wrist Larsen grade greater than 4. Dislocation of the distal end of the ulna, carpal collapse, and the scallop sign on X-ray indicated a higher probability of extensor tendon rupture. Rheumatologists should consult with hand surgeons promptly to preserve hand function before tendon rupture. Prophylactic extended tenosynovectomy

  11. Relation between flexor spasms, uninhibited detrusor contractions and anal sphincter activity

    DEFF Research Database (Denmark)

    Pedersen, E; Petersen, T; Schrøder, H D

    1986-01-01

    The time relation between flexor spasms, detrusor contractions and anal sphincter activity was recorded in a consecutive series of 111 patients with hyperreflexic bladder and flexor spasms. In 76 of the patients flexor spasms were preceded by detrusor contractions. The opposite pattern, namely de...

  12. Fibrillar organization in tendons: A pattern revealed by percolation characteristics of the respective geometric network

    Directory of Open Access Journals (Sweden)

    Daniel Andres Dos Santos

    2014-06-01

    Full Text Available Since the tendon is composed by collagen fibrils of various sizes connected between them through molecular cross-links, it sounds logical to model it via a heterogeneous network of fibrils. Using cross sectional images, that network is operatively inferred from the respective Gabriel graph of the fibril mass centers. We focus on network percolation characteristics under an ordered activation of fibrils (progressive recruitment going from the smallest to the largest fibril. Analyses of percolation were carried out on a repository of images of digital flexor tendons obtained from samples of lizards and frogs. Observed percolation thresholds were compared against values derived from hypothetical scenarios of random activation of nodes. Strikingly, we found a significant delay for the occurrence of percolation in actual data. We interpret this finding as the consequence of some non-random packing of fibrillar units into a size-constrained geometric pattern. We erect an ideal geometric model of balanced interspersion of polymorphic units that accounts for the delayed percolating instance. We also address the circumstance of being percolation curves mirrored by the empirical curves of stress-strain obtained from the same studied tendons. By virtue of this isomorphism, we hypothesize that the inflection points of both curves are different quantitative manifestations of a common transitional process during mechanical load transference.

  13. No Telescoping Effect with Dual Tendon Vibration.

    Directory of Open Access Journals (Sweden)

    Valeria Bellan

    Full Text Available The tendon vibration illusion has been extensively used to manipulate the perceived position of one's own body part. However, findings from previous research do not seem conclusive sregarding the perceptual effect of the concurrent stimulation of both agonist and antagonist tendons over one joint. On the basis of recent data, it has been suggested that this paired stimulation generates an inconsistent signal about the limb position, which leads to a perceived shrinkage of the limb. However, this interesting effect has never been replicated. The aim of the present study was to clarify the effect of a simultaneous and equal vibration of the biceps and triceps tendons on the perceived location of the hand. Experiment 1 replicated and extended the previous findings. We compared a dual tendon stimulation condition with single tendon stimulation conditions and with a control condition (no vibration on both 'upward-downward' and 'towards-away from the elbow' planes. Our results show a mislocalisation towards the elbow of the position of the vibrated arm during dual vibration, in line with previous results; however, this did not clarify whether the effect was due to arm representation contraction (i.e., a 'telescoping' effect. Therefore, in Experiment 2 we investigated explicitly and implicitly the perceived arm length during the same conditions. Our results clearly suggest that in all the vibration conditions there was a mislocalisation of the entire arm (including the elbow, but no evidence of a contraction of the perceived arm length.

  14. Monosynaptic Ia projections from intrinsic hand muscles to forearm motoneurones in humans.

    Science.gov (United States)

    Marchand-Pauvert, V; Nicolas, G; Pierrot-Deseilligny, E

    2000-05-15

    Heteronymous Ia excitatory projections from intrinsic hand muscles to human forearm motoneurones (MNs) were investigated. Changes in firing probability of single motor units (MUs) in the flexor carpi radialis (FCR), flexor carpi ulnaris (FCU), flexor digitorum superficialis (FDS), extensor carpi radialis (ECR), extensor carpi ulnaris (ECU) and extensor digitorum communis (EDC) were studied after electrical stimuli were applied to the median and ulnar nerve at wrist level and to the corresponding homonymous nerve at elbow level. Homonymous facilitation, occurring at the same latency as the H reflex, and therefore attributed to monosynaptic Ia EPSPs, was found in all the sampled units. In many MUs an early facilitation was also evoked by heteronymous low-threshold afferents from intrinsic hand muscles. The low threshold (between 0.5 and 0.6 times motor threshold (MT)) and the inability of a pure cutaneous stimulation to reproduce this effect indicate that it is due to stimulation of group I muscle afferents. Evidence for a similar central delay (monosynaptic) in heteronymous as in homonymous pathways was accepted when the difference in latencies of the homonymous and heteronymous peaks did not differ from the estimated supplementary afferent conduction time from wrist to elbow level by more than 0.5 ms (conduction velocity in the fastest Ia afferents between wrist and elbow levels being equal to 69 m s-1). A statistically significant heteronymous monosynaptic Ia excitation from intrinsic hand muscles supplied by both median and ulnar nerves was found in MUs belonging to all forearm motor nuclei tested (although not in ECU MUs after ulnar stimulation). It was, however, more often found in flexors than in extensors, in wrist than in finger muscles and in muscles operating in the radial than in the ulnar side. It is argued that the connections of Ia afferents from intrinsic hand muscles to forearm MNs, which are stronger and more widely distributed than in the cat

  15. The Effect of 5 FU on the Expression of Transforming Growth Factor Beta-1 (Tgf-1 in Cultured Tendon Cells

    Directory of Open Access Journals (Sweden)

    Zeynep Karacor Altuntas

    2014-10-01

    Full Text Available This study investigated the effect of the treatment with 1 min exposures to 5-fluorouracil (5-FU  on the expression of TGF-beta 1 in cultured tendon cells. Fibroblasts cultured from the flexor tendons of dog paws were treated with 3 different doses of 5-FU ( control, 5-15-25 mgr /ml for 1 minute.  After 5-FU exposure  the expression of TGF –beta 1 were tested by real time Reverse Transcriptase-Polymerase Chain Reaction (RT-PCR at 3rd and 7th days. There were no statistically significant differences in the expression levels of the TGF-b1 gene between the control group and all other groups on day 3 and 7 (p>0.05.However, when the percentage changes in the TGF-BETA1 gene expression on days 3–7 were compared, there were statistically significant differences and this was maximally observed with 89% +12 (p<0.05 in the group treated with 25-mg/ml 5-FU.  We conclude that 1min. 5-FU application may be  sufficient to prevent adhesions in tendon healing by limiting the expression of TGF-BETA1. 

  16. Magnetic resonance imaging and ultrasonography in diagnosing arthritis of the hand joints: a comparative study

    International Nuclear Information System (INIS)

    Ciechomska, A.; Bachta, A.; Tlustochowicz, W.; Serafin-Krol, M.; Jakubowski, W.; Andrysiak, R.; Krolicki, L.

    2005-01-01

    Assessment of joint inflammation in clinical practice is based on physical examination. Imaging modalities which allow soft tissues to be visualized may be helpful in making the assessment impartial and to evaluate the severity of inflammation. The aim of the study was to compare magnetic resonance imaging (MRI) and ultrasonography (USG) findings in visualizing joint inflammation of the hand. The study comprised 113 patients with chronic arthritis, of whom 88 patients had rheumatoid arthritis (RA) and 25 arthritis of etiology unconnected with RA. MRI of the hand was performed in 98 patients and USG of the hand in 86 patients. Sixty-four patients underwent both USG and MRI. In the USG examinations a linear, high-frequency transducer of 5-9 MHz and a Color Doppler option (CD-USG) were used. MRI was performed with a 1.5 T unit in the SE sequences T1, T1 with fat saturation, and before and after Gd-DTPA injection. Assessed joints included the wrist joints, etacarpophalangeal joints, and proximal and distal interphalangeal joints (1921 joints in total). Tenosynovitis of the flexors and extensors was also evaluated. MRI showed inflammation in 277 joints (16.6%) of 66 patients. The mean number of inflamed joints found using MRI was 2.8 ± 2.9. US visualized synovitis in a larger number of joints (350, 23.9%) in 63 patients. The mean number of inflamed joints found by USG was 4.1 ± 4.0. Increased blood flow on CD-USG was seen in 202 joints (13.8%) of 72 patients. The difference between RA and non-RA patients as visible on MRI and USG were statistically significant. There were correlations in showing joint inflammation between MRI and USG (τ = 0.64; p < 0.00001) and between CD-USG and MRI (τ = 0.44; p < 0.00001) and concordance in showing flexor tendon sheath inflammation. MRI and USG both show inflammation of the joints. The concordance between the methods in showing joint inflammation depends upon analyzing the features of inflammation. Availability and the

  17. Measurement of fatigue in knee flexor and extensor muscles.

    Science.gov (United States)

    Kawabata, Y; Senda, M; Oka, T; Yagata, Y; Takahara, Y; Nagashima, H; Inoue, H

    2000-04-01

    In order to examine fatigue of the knee flexor and extensor muscles and to investigate the characteristics of muscular fatigue in different sports, a Cybex machine was used to measure muscle fatigue and recovery during isokinetic knee flexion and extension. Eighteen baseball players, 12 soccer players and 13 marathon runners were studied. Each subject was tested in the sitting position and made to perform 50 consecutive right knee bends and stretches at maximum strength. This was done 3 times with an interval of 10 min between each series. The peak torque to body weight ratio and the fatigue rate were determined in each case. In all subjects, the peak torque to body weight ratio was higher for extensors than flexors. Over the 3 trials, the fatigue rate of extensors showed little change, while that of flexors had a tendency to increase. In each subject, knee extensors showed a high fatigue rate but a quick recovery, while knee flexors showed a low fatigue rate but a slow recovery. As the marathon runners had the smallest fatigue rates for both flexors and extensors, we concluded that marathon runners had more stamina than baseball players and soccer players.

  18. Extensor Tendon Instability Due to Sagittal Band Injury in a Martial Arts Athlete: A Case Report.

    Science.gov (United States)

    Kochevar, Andrew; Rayan, Ghazi

    2017-03-01

    A Taekwondo participant sustained a hand injury from punching an opponent that resulted in painful instability of the ring finger extensor digitorum communis tendon due to sagittal band damage. His symptoms resolved after reconstructive surgery on the sagittal band (SB) with stabilization of the extensor tendon over the metacarpophalangeal joint.

  19. Implications of obesity for tendon structure, ultrastructure and biochemistry: a study on Zucker rats.

    Science.gov (United States)

    Biancalana, Adriano; Velloso, Lício Augusto; Taboga, Sebastião Roberto; Gomes, Laurecir

    2012-02-01

    The extracellular matrix consists of collagen, proteoglycans and non-collagen proteins. The incidence of obesity and associated diseases is currently increasing in developed countries. Obesity is considered to be a disease of modern times, and genes predisposing to the disease have been identified in humans and animals. The objective of the present study was to compare the morphological and biochemical aspects of the deep digital flexor tendon of lean (Fa/Fa or Fa/fa) and genetically obese (fa/fa) Zucker rats. Ultrastructural analysis showed the presence of lipid droplets in both groups, whereas disorganized collagen fibril bundles were observed in obese animals. Lean animals presented a larger amount of non-collagen proteins and glycosaminoglycans than obese rats. We propose that the overweight and lesser physical activity in obese animals may have provoked the alterations in the composition and organization of extracellular matrix components but a genetic mechanism cannot be excluded. These alterations might be related to organizational and structural modifications in the collagen bundles that influence the mechanical properties of tendons and the progression to a pathological state. Copyright © 2011 Elsevier Ltd. All rights reserved.

  20. Torque control of underactuated tendon-driven fingers

    Directory of Open Access Journals (Sweden)

    M. E. Abdallah

    2011-02-01

    Full Text Available Given an underactuated tendon-driven finger, the finger posture is underdetermined and can move freely ("flop" in a region of slack tendons. This work shows that such an underactuated finger can be operated in tendon force control (rather than position control with effective performance. The force control eliminates the indeterminate slack while commanding a parameterized space of desired torques. The torque will either push the finger to the joint limits or wrap around an external object with variable torque – behavior that is sufficient for primarily gripping fingers. In addition, introducing asymmetric joint radii to the design allows the finger to command an expanded range of joint torques and to scan an expanded set of external surfaces. This study is motivated by the design and control of the secondary fingers of the NASA-GM R2 humanoid hand.

    This paper was presented at the IFToMM/ASME International Workshop on Underactuated Grasping (UG2010, 19 August 2010, Montréal, Canada.

  1. Contrast-enhanced computed tomographic evaluation of the deep digital flexor tendon in the equine foot compared to macroscopic and histological findings in 23 limbs

    NARCIS (Netherlands)

    van Hamel, S E; Bergman, H J; Puchalski, S M; Groot, M.W.; van Weeren, P R

    2014-01-01

    REASONS FOR PERFORMING THE STUDY: Distal deep digital flexor tendinopathy is an important cause of foot lameness in horses that is difficult to diagnose with radiography and ultrasonography. Magnetic resonance imaging is a well-accepted and validated technique for the identification of deep digital

  2. Tubercular tenosynovitis of extensor tendons of foot--a rare ...

    African Journals Online (AJOL)

    Tuberculosis of soft tissues as a result of spread from adjacent bone or joint is a well recognized entity. However isolated tuberculous pyomyositis, bursitis and tenosynovitis are rare, constituting about 1% of skeletal tuberculosis. Tubercular tenosynovitis commonly involves tendon sheaths of wrist and hand. Cases of ...

  3. The Avocado Hand

    LENUS (Irish Health Repository)

    Rahmani, G

    2017-11-01

    Accidental self-inflicted knife injuries to digits are a common cause of tendon and nerve injury requiring hand surgery. There has been an apparent increase in avocado related hand injuries. Classically, the patients hold the avocado in their non-dominant hand while using a knife to cut\\/peel the fruit with their dominant hand. The mechanism of injury is usually a stabbing injury to the non-dominant hand as the knife slips past the stone, through the soft avocado fruit. Despite their apparent increased incidence, we could not find any cases in the literature which describe the “avocado hand”. We present a case of a 32-year-old woman who sustained a significant hand injury while preparing an avocado. She required exploration and repair of a digital nerve under regional anaesthesia and has since made a full recovery.

  4. FIBRILLINS IN TENDON

    Directory of Open Access Journals (Sweden)

    Betti Giusti

    2016-10-01

    Full Text Available Tendons among connective tissue, mainly collagen, contain also elastic fibres made of fibrillin 1, fibrillin 2 and elastin that are broadly distributed in tendons and represent 1-2% of the dried mass of the tendon. Only in the last years, studies on structure and function of elastic fibres in tendons have been performed. Aim of this review is to revise data on the organization of elastic fibres in tendons, in particular fibrillin structure and function, and on the clinical manifestations associated to alterations of elastic fibres in tendons. Indeed, microfibrils may contribute to tendon mechanics; therefore, their alterations may cause joint hypermobility and contractures which have been found to be clinical features in patients with Marfan syndrome and Beals syndrome. The two diseases are caused by mutations in genes FBN1 and FBN2 encoding fibrillin 1 and fibrillin 2, respectively.

  5. Achilles tendon of wistar rats treated with laser therapy and eccentric exercise

    Directory of Open Access Journals (Sweden)

    Maria Verônica de Souza

    2015-10-01

    as a healthy tendon. On the other hand, it also does not influence negatively the structure and function of the Achilles tendon.

  6. Case report 466: Granulomatous tenosynovitis (left 3rd finger)

    Energy Technology Data Exchange (ETDEWEB)

    Waggenspack, G.A.; Amparo, E.G.

    1988-03-01

    The magnetic resonance features of a digital flexor tendon sheath mass are described in a patient with a painless enlarged digit. MRI provided precise anatomical localization of a caseating granulomatous mass within the flexor tendon sheath space and facilitated definitive surgical treatment, whereas the radiographic findings showed soft tissue swelling of the phalanx but were unable to compartmentalize or characterize the underlying abnormality.

  7. Active Achilles tendon kinesitherapy accelerates Achilles tendon repair by promoting neurite regeneration.

    Science.gov (United States)

    Jielile, Jiasharete; Aibai, Minawa; Sabirhazi, Gulnur; Shawutali, Nuerai; Tangkejie, Wulanbai; Badelhan, Aynaz; Nuerduola, Yeermike; Satewalede, Turde; Buranbai, Darehan; Hunapia, Beicen; Jialihasi, Ayidaer; Bai, Jingping; Kizaibek, Murat

    2012-12-15

    Active Achilles tendon kinesitherapy facilitates the functional recovery of a ruptured Achilles tendon. However, protein expression during the healing process remains a controversial issue. New Zealand rabbits, aged 14 weeks, underwent tenotomy followed immediately by Achilles tendon microsurgery to repair the Achilles tendon rupture. The tendon was then immobilized or subjected to postoperative early motion treatment (kinesitherapy). Mass spectrography results showed that after 14 days of motion treatment, 18 protein spots were differentially expressed, among which, 12 were up-regulated, consisting of gelsolin isoform b and neurite growth-related protein collapsing response mediator protein 2. Western blot analysis showed that gelsolin isoform b was up-regulated at days 7-21 of motion treatment. These findings suggest that active Achilles tendon kinesitherapy promotes the neurite regeneration of a ruptured Achilles tendon and gelsolin isoform b can be used as a biomarker for Achilles tendon healing after kinesitherapy.

  8. Active Achilles tendon kinesitherapy accelerates Achilles tendon repair by promoting neurite regeneration☆

    Science.gov (United States)

    Jielile, Jiasharete; Aibai, Minawa; Sabirhazi, Gulnur; Shawutali, Nuerai; Tangkejie, Wulanbai; Badelhan, Aynaz; Nuerduola, Yeermike; Satewalede, Turde; Buranbai, Darehan; Hunapia, Beicen; Jialihasi, Ayidaer; Bai, Jingping; Kizaibek, Murat

    2012-01-01

    Active Achilles tendon kinesitherapy facilitates the functional recovery of a ruptured Achilles tendon. However, protein expression during the healing process remains a controversial issue. New Zealand rabbits, aged 14 weeks, underwent tenotomy followed immediately by Achilles tendon microsurgery to repair the Achilles tendon rupture. The tendon was then immobilized or subjected to postoperative early motion treatment (kinesitherapy). Mass spectrography results showed that after 14 days of motion treatment, 18 protein spots were differentially expressed, among which, 12 were up-regulated, consisting of gelsolin isoform b and neurite growth-related protein collapsing response mediator protein 2. Western blot analysis showed that gelsolin isoform b was up-regulated at days 7–21 of motion treatment. These findings suggest that active Achilles tendon kinesitherapy promotes the neurite regeneration of a ruptured Achilles tendon and gelsolin isoform b can be used as a biomarker for Achilles tendon healing after kinesitherapy. PMID:25317130

  9. Palmaris Longus Muscle in the South Indian Population – A Cadaveric Study

    Directory of Open Access Journals (Sweden)

    Lydia S. Quadros

    2017-07-01

    Full Text Available Introduction: Palmaris longus, one of the superficial flexor muscles of the anterior compartment of the forearm is the most variable muscle of the upper limb. Purpose: To note the variations of palmaris longus for tendon grafts. Methods: Forty formalin-fixed upper limb specimens of South Indian population were dissected to note the variations of Palmaris longus muscle. Results: Out of the forty upper limb specimens, two variants of the palmaris longus were noted. In one specimen, a reversed palmaris longus was noted. It had a long tendinous origin with a muscle belly and a short flat tendon at insertion. The tendon inserted partly into the flexor retinaculum and partly into palmar aponeurosis. In another specimen, apart from the normal palmaris longus muscle, an additional smaller muscle was noted. It was the Palmaris profundus. This muscle took origin in the form of a tendon from the middle of the shaft of the radius, continued as a muscle belly and then terminated as a tendon which later inserted into the flexor retinaculum, close to the tendon of palmaris longus muscle. At its insertion, the superficial palmar branch of radial artery hooked it. The anterior interosseous nerve supplied the Palmaris profundus. Conclusion: These variations are worthy to be noted for tendon grafts.

  10. Modulation of hand aperture during reaching in persons with incomplete cervical spinal cord injury.

    Science.gov (United States)

    Stahl, Victoria A; Hayes, Heather B; Buetefisch, Cathrin M; Wolf, Steven L; Trumbower, Randy D

    2015-03-01

    The intact neuromotor system prepares for object grasp by first opening the hand to an aperture that is scaled according to object size and then closing the hand around the object. After cervical spinal cord injury (SCI), hand function is significantly impaired, but the degree to which object-specific hand aperture scaling is affected remains unknown. Here, we hypothesized that persons with incomplete cervical SCI have a reduced maximum hand opening capacity but exhibit novel neuromuscular coordination strategies that permit object-specific hand aperture scaling during reaching. To test this hypothesis, we measured hand kinematics and surface electromyography from seven muscles of the hand and wrist during attempts at maximum hand opening as well as reaching for four balls of different diameters. Our results showed that persons with SCI exhibited significantly reduced maximum hand aperture compared to able-bodied (AB) controls. However, persons with SCI preserved the ability to scale peak hand aperture with ball size during reaching. Persons with SCI also used distinct muscle coordination patterns that included increased co-activity of flexors and extensors at the wrist and hand compared to AB controls. These results suggest that motor planning for aperture modulation is preserved even though execution is limited by constraints on hand opening capacity and altered muscle co-activity. Thus, persons with incomplete cervical SCI may benefit from rehabilitation aimed at increasing hand opening capacity and reducing flexor-extensor co-activity at the wrist and hand.

  11. Case report 466: Granulomatous tenosynovitis (left 3rd finger)

    International Nuclear Information System (INIS)

    Waggenspack, G.A.; Amparo, E.G.

    1988-01-01

    The magnetic resonance features of a digital flexor tendon sheath mass are described in a patient with a painless enlarged digit. MRI provided precise anatomical localization of a caseating granulomatous mass within the flexor tendon sheath space and facilitated definitive surgical treatment, whereas the radiographic findings showed soft tissue swelling of the phalanx but were unable to compartmentalize or characterize the underlying abnormality. (orig.)

  12. Ulnar-sided pain due to extensor carpi ulnaris tendon subluxation: a case report

    Directory of Open Access Journals (Sweden)

    Cift Hakan

    2012-11-01

    Full Text Available Abstract Introduction We present the case of a patient with extensor carpi ulnaris tendon subluxation who was first treated for distal radioulnar joint sprain. Case presentation A 25-year-old Caucasian man was seen at our policlinic one month after he had fallen on his outstretched hand. A diagnosis of extensor carpi ulnaris subluxation was made clinically but we also had the magnetic resonance imaging scan of the patient’s wrist which displayed an increased signal on T2-weighted images consistent with inflammation around the extensor carpi ulnaris tendon. The extensor carpi ulnaris tendon was found to be dislocating during supination and relocating during pronation. The sheath was reconstructed using extensor retinaculum due to attenuation of subsheath. Conclusion There was no recurrent dislocation of the extensor carpi ulnaris tendon of the patient at his last follow up 12 months after the operation.

  13. Towards the design of a prosthetic underactuated hand

    Directory of Open Access Journals (Sweden)

    T. Laliberté

    2010-12-01

    Full Text Available This paper presents recent advances in the design of an underactuated hand for applications in prosthetics. First, the design of the fingers is addressed. Based on previous experiments with prototypes developed in the past, new tendon routings are proposed that lead to a more effective transmission of the forces. A novel elastic tendon routing is also proposed for the passive opening of the hand. A simplified static analysis of the fingers is proposed to support the results. Then, a new kinematic design of the thumb is presented. The thumb is designed to perform out-of-the-plane motions in order to broaden the variety of possible grasps. A mechanism for the implementation of underactuation between the fingers is proposed that alleviates the friction problems encountered in earlier hand designs. Finally, a prototype of the hand is briefly described and typical grasps are shown.

    This paper was presented at the IFToMM/ASME International Workshop on Underactuated Grasping (UG2010, 19 August 2010, Montréal, Canada.

  14. Ulnar-sided wrist pain. II. Clinical imaging and treatment

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Atsuya; Souza, Felipe [Brigham and Women' s Hospital, Department of Radiology, Boston, MA (United States); Vezeridis, Peter S.; Blazar, Philip [Brigham and Women' s Hospital, Department of Orthopaedic Surgery, Boston, MA (United States); Yoshioka, Hiroshi [Brigham and Women' s Hospital, Department of Radiology, Boston, MA (United States); University of California-Irvine, Department of Radiological Sciences, Irvine, CA (United States); UC Irvine Medical Center, Department of Radiological Sciences, Orange, CA (United States)

    2010-09-15

    Pain at the ulnar aspect of the wrist is a diagnostic challenge for hand surgeons and radiologists due to the small and complex anatomical structures involved. In this article, imaging modalities including radiography, arthrography, ultrasound (US), computed tomography (CT), CT arthrography, magnetic resonance (MR) imaging, and MR arthrography are compared with regard to differential diagnosis. Clinical imaging findings are reviewed for a more comprehensive understanding of this disorder. Treatments for the common diseases that cause the ulnar-sided wrist pain including extensor carpi ulnaris (ECU) tendonitis, flexor carpi ulnaris (FCU) tendonitis, pisotriquetral arthritis, triangular fibrocartilage complex (TFCC) lesions, ulnar impaction, lunotriquetral (LT) instability, and distal radioulnar joint (DRUJ) instability are reviewed. (orig.)

  15. Isolated Tuberculous Tenosynovitis of the Anterior Tibial and Extensor Digitorum Longus Tendons

    Directory of Open Access Journals (Sweden)

    Berhan Genç

    2013-01-01

    Full Text Available Musculoskeletal system is involved in 1-5% of extrapulmonary cases of tuberculosis. Tuberculous tenosynovitis is a rare form of musculoskeletal tuberculosis. Tuberculosis of the tendon sheath in the hand has been seen in a few cases. Involvement of the tendons of the leg is less common. Diagnosis is not easy as there are no specific clinical symptoms or signs. A 33-year-old male presented with painful swelling in the distal right lower limb that caused restriction of movement. Imaging studies showed inflammation and infection of the extensor digitorium longus and tibialis anterior tendons. Histopathological studies showed a necrotizing granulomatous inflammation in the synovial tissue. A diagnosis of tuberculosis was made and medical treatment was initiated that proved successful. Patient remained infection-free at 26-month follow-up examination.

  16. Ipsilateral free semitendinosus tendon graft transfer for reconstruction of chronic tears of the Achilles tendon

    Directory of Open Access Journals (Sweden)

    Gougoulias Nikolaos

    2008-07-01

    Full Text Available Abstract Background Many techniques have been developed for the reconstruction of the Achilles tendon in chronic tears. In presence of a large gap (greater than 6 centimetres, tendon augmentation is required. Methods We present our method of minimally invasive semitendinosus reconstruction for the Achilles tendon using one para-midline and one midline incision. Results The first incision is a 5 cm longitudinal incision, made 2 cm proximal and just medial to the palpable end of the residual tendon. The second incision is 3 cm long and is also longitudinal but is 2 cm distal and in the midline to the distal end of the tendon rupture. The distal and proximal Achilles tendon stumps are mobilised. After trying to reduce the gap of the ruptured Achilles tendon, if the gap produced is greater than 6 cm despite maximal plantar flexion of the ankle and traction on the Achilles tendon stumps, the ipsilateral semitendinosus tendon is harvested. The semitendinosus tendon is passed through small incisions in the substance of the proximal stump of the Achilles tendon, and it is sutured to the Achilles tendon. It is then passed beneath the intact skin bridge into the distal incision, and passed from medial to lateral through a transverse tenotomy in the distal stump. With the ankle in maximal plantar flexion, the semitendinosus tendon is sutured to the Achilles tendon at each entry and exit point Conclusion This minimally invasive technique allows reconstruction of the Achilles tendon using the tendon of semitendinosus preserving skin integrity over the site most prone to wound breakdown, and can be especially used to reconstruct the Achilles tendon in the presence of large gap (greater than 6 centimetres.

  17. Unique Role of Occupational Therapy in Rehabilitation of the Hand

    Science.gov (United States)

    ... tendonitis, rheumatoid arthritis and osteoarthritis, and carpal tunnel syndrome also are treated by occupational therapy practitioners specializing in hand rehabilitation. Practitioners who treat ...

  18. Different culture conditions affect the growth of human tendon stem/progenitor cells (TSPCs) within a mixed tendon cells (TCs) population.

    Science.gov (United States)

    Viganò, M; Perucca Orfei, C; Colombini, A; Stanco, D; Randelli, P; Sansone, V; de Girolamo, L

    2017-12-01

    Tendon resident cells (TCs) are a mixed population made of terminally differentiated tenocytes and tendon stem/progenitor cells (TSPCs). Since the enrichment of progenitors proportion could enhance the effectiveness of treatments based on these cell populations, the interest on the effect of culture conditions on the TSPCs is growing. In this study the clonal selection and the culture in presence or absence of basic fibroblast growth factor (bFGF) were used to assess their influences on the stemness properties and phenotype specific features of tendon cells. Cells cultured with the different methods were analyzed in terms of clonogenic and differentiation abilities, stem and tendon specific genes expression and immunophenotype at passage 2 and passage 4. The clonal selection allowed to isolate cells with a higher multi-differentiation potential, but at the same time a lower proliferation rate in comparison to the whole population. Moreover, the clones express a higher amounts of stemness marker OCT4 and tendon specific transcription factor Scleraxis (SCX) mRNA, but a lower level of decorin (DCN). On the other hand, the number of cells obtained by clonal selection was extremely low and most of the clones were unable to reach a high number of passages in cultures. The presence of bFGF influences TCs morphology, enhance their proliferation rate and reduce their clonogenic ability. Interestingly, the expression of CD54, a known mesenchymal stem cell marker, is reduced in presence of bFGF at early passages. Nevertheless, bFGF does not affect the chondrogenic and osteogenic potential of TCs and the expression of tendon specific markers, while it was able to downregulate the OCT4 expression. This study showed that clonal selection enhance progenitors content in TCs populations, but the extremely low number of cells produced with this method could represent an insurmountable obstacle to its application in clinical approaches. We observed that the addition of bFGF to the

  19. Development and Validation of the OMERACT Rheumatoid Arthritis Magnetic Resonance Tenosynovitis Scoring System in a Multireader Exercise.

    Science.gov (United States)

    Glinatsi, Daniel; Bird, Paul; Gandjbakhch, Frédérique; Haavardsholm, Espen A; Peterfy, Charles G; Vital, Edward M; Emery, Paul; Conaghan, Philip G; Østergaard, Mikkel

    2017-11-01

    To develop and validate a magnetic resonance imaging (MRI) tenosynovitis (TS) score for tendons at the wrist and metacarpophalangeal (MCP) joint levels in patients with rheumatoid arthritis (RA). Axial T1-weighted precontrast and postcontrast fat-saturated MR image sets of the hands of 43 patients with RA initiating rituximab therapy were obtained at baseline and after 14, 26, 38, or 52 weeks. The MR images were scored twice by 4 readers. Nine tendon compartments of the wrist and 4 flexor tendon compartments at the MCP joints were assessed. Tenosynovitis was scored as follows: 0: No; 1: The overall PEA/PCA intrareader and interreader agreements for change scores in all tendons were 73.8%/97.6% and 47.9%/85.0%, respectively. Average SRM was moderate for total scores and 60.5% of the patients had a tenosynovitis change score ≥ SDC. The TS score showed high intrareader and interreader agreement for wrist and finger tendons, with moderate responsiveness, and the majority of the patients showed a change above the SDC. This scoring system may be included as a component of the RAMRIS.

  20. Open extensor tendon injuries: an epidemiologic study.

    Science.gov (United States)

    Patillo, Dominic; Rayan, Ghazi M

    2012-01-01

    To report the epidemiology, mechanism, anatomical location, distribution, and severity of open extensor tendon injuries in the digits, hand, and forearm as well as the frequency of associated injuries to surrounding bone and soft tissue. Retrospective chart review was conducted for patients who had operative repair of open digital extensor tendon injuries in all zones within an 11-year period. Data was grouped according to patient characteristics, zone of injury, mechanism of injury, and presence of associated injury. Statistical analysis was used to determine the presence of relevant associations. Eighty-six patients with 125 severed tendons and 105 injured digits were available for chart reviews. Patients were predominantly males (83%) with a mean age of 34.2 years and the dominant extremity was most often injured (60%). The thumb was the most commonly injured (25.7%), followed by middle finger (24.8), whereas small finger was least affected (10.5%). Sharp laceration was the most common mechanism of injury (60%), and most of these occurred at or proximal to the metacarpophalangeal joints. Most saw injuries occurred distal to the metacarpophalangeal joint. Zone V was the most commonly affected in the fingers (27%) while zone VT was the most commonly affected in the thumb (69%). Associated injuries to bone and soft tissue occurred in 46.7% of all injuries with saw and crush/avulsions being predictive of fractures and damage to the underlying joint capsule. The extensor mechanism is anatomically complex, and open injuries to the dorsum of the hand, wrist, and forearm, especially of crushing nature and those inflicted by saws, must be thoroughly evaluated. Associated injuries should be ruled out in order to customize surgical treatment and optimize outcome.

  1. Achilles Tendonitis

    Science.gov (United States)

    ... almost impossible. Achilles tendonitis is a very common running injury. But it can also affect basketball players, dancers, ... Proximal Biceps Tendonitis Safety Tips: Basketball Safety Tips: Running Repetitive Stress Injuries Sports and Exercise Safety Dealing With Sports Injuries ...

  2. Development of a prototype over-actuated biomimetic prosthetic hand.

    Directory of Open Access Journals (Sweden)

    Matthew R Williams

    Full Text Available The loss of a hand can greatly affect quality of life. A prosthetic device that can mimic normal hand function is very important to physical and mental recuperation after hand amputation, but the currently available prosthetics do not fully meet the needs of the amputee community. Most prosthetic hands are not dexterous enough to grasp a variety of shaped objects, and those that are tend to be heavy, leading to discomfort while wearing the device. In order to attempt to better simulate human hand function, a dexterous hand was developed that uses an over-actuated mechanism to form grasp shape using intrinsic joint mounted motors in addition to a finger tendon to produce large flexion force for a tight grip. This novel actuation method allows the hand to use small actuators for grip shape formation, and the tendon to produce high grip strength. The hand was capable of producing fingertip flexion force suitable for most activities of daily living. In addition, it was able to produce a range of grasp shapes with natural, independent finger motion, and appearance similar to that of a human hand. The hand also had a mass distribution more similar to a natural forearm and hand compared to contemporary prosthetics due to the more proximal location of the heavier components of the system. This paper describes the design of the hand and controller, as well as the test results.

  3. Mechanical Properties of Human Patellar Tendon at the Hierarchical levels of Tendon and Fibril

    DEFF Research Database (Denmark)

    Svensson, Rene Brüggebusch; Hansen, Philip; Hassenkam, Tue

    2012-01-01

    Tendons are strong hierarchical structures, but how tensile forces are transmitted between different levels remains incompletely understood. Collagen fibrils are thought to be primary determinants of whole tendon properties, and therefore we hypothesized that the whole human patellar tendon and its...... distinct collagen fibrils would display similar mechanical properties. Human patellar tendons (n=5) were mechanically tested in vivo by ultrasonography. Biopsies were obtained from each tendon and individual collagen fibrils were dissected and tested mechanically by atomic force microscopy. The Young...... that of tendon supports that fibrillar rather than interfibrillar properties govern sub-failure tendon response, making the fibrillar level a meaningful target of intervention. The lower modulus found in vitro suggests a possible adverse effect of removing the tissue from its natural environment. In addition...

  4. Fibroma of the tendon sheath of the long head of the biceps tendon

    International Nuclear Information System (INIS)

    Maeseneer, Michel de; Shahabpour, Maryam; Isacker, Tom van; Lenchik, Leon; Caillie, Marie-Astrid van

    2014-01-01

    Fibroma of the tendon sheath is a benign tumor that is less common than giant cell tumor of the tendon sheath. Both tumors may present as a painless, slowly enlarging mass. Radiological findings may be similar for both tumors. Histologically, fibroma of the tendon sheath lacks the hemosiderin-laden macrophages that are typical for giant cell tumor of the tendon sheath. We report on a 49-year-old woman with fibroma of the tendon sheath of the long head of the biceps tendon. In our case, on MR images, we observed band-like hypointense areas centrally in the tumor, mild patchy contrast enhancement, and most importantly, no decrease of signal intensity on gradient echo images. These characteristics reflected histological findings. (orig.)

  5. Achilles tendon and sports

    International Nuclear Information System (INIS)

    Ulreich, N.; Kainberger, F.; Huber, W.; Nehrer, S.

    2002-01-01

    Because of the rising popularity of recreational sports activities achillodynia is an often associated symptom with running, soccer and athletics. Therefore radiologist are frequently asked to image this tendon. The origin of the damage of the Achilles tendon is explained by numerous hypothesis, mainly a decreased perfusion and a mechanical irritation that lead to degeneration of the tendon. High-resolution technics such as sonography and magnetic resonance imaging show alterations in the structure of the tendon which can be graduated and classified. Manifestations like tendinosis, achillobursitis, rupture and Haglunds disease can summarized as the tendon overuse syndrom. A rupture of a tendon is mostly the result of a degeneration of the collagenfibres. The task of the radiologist is to acquire the intrinsic factors for a potential rupture. (orig.) [de

  6. Periodic modulation of motor-unit activity in extrinsic hand muscles during multidigit grasping.

    Science.gov (United States)

    Johnston, Jamie A; Winges, Sara A; Santello, Marco

    2005-07-01

    We recently examined the extent to which motor units of digit flexor muscles receive common input during multidigit grasping. This task elicited moderate to strong motor-unit synchrony (common input strength, CIS) across muscles (flexor digitorum profundus, FDP, and flexor pollicis longus, FPL) and across FDP muscle compartments, although the strength of this common input was not uniform across digit pairs. To further characterize the neural mechanisms underlying the control of multidigit grasping, we analyzed the relationship between firing of single motor units from these hand muscles in the frequency domain by computing coherence. We report three primary findings. First, in contrast to what has been reported in intrinsic hand muscles, motor units belonging to different muscles and muscle compartments of extrinsic digit flexors exhibited significant coherence in the 0- to 5- and 5- to 10-Hz frequency ranges and much weaker coherence in the higher 10-20 Hz range (maximum 0.0025 and 0.0008, respectively, pooled across all FDP compartment pairs). Second, the strength and incidence of coherence differed considerably across digit pairs. Third, contrary to what has been reported in the literature, across-muscle coherence can be stronger and more prevalent than within-muscle coherence, as FPL-FDP2 (thumb-index digit pair) exhibited the strongest and most prevalent coherence in our data (0.010 and 43% at 3 Hz, respectively). The heterogeneous organization of common input to these muscles and muscle compartments is discussed in relation to the functional role of individual digit pairs in the coordination of multiple digit forces in grasping.

  7. Correlation between toe flexor strength and ankle dorsiflexion ROM during the countermovement jump.

    Science.gov (United States)

    Yun, Sung Joon; Kim, Moon-Hwan; Weon, Jong-Hyuck; Kim, Young; Jung, Sung-Hoon; Kwon, Oh-Yun

    2016-08-01

    [Purpose] This study assessed the relationships between peak toe flexor muscle strength, ankle dorsiflexion range of motion, and countermovement jump height. [Subjects and Methods] Eighteen healthy volunteers participated in the study. Each participant completed tests for peak toe flexor muscle strength, ankle dorsiflexion range of motion, and countermovement jump height. [Results] The results showed (1) a moderate correlation between ankle dorsiflexion range of motion and countermovement jump height and (2) a high correlation between peak first toe flexor muscle strength and countermovement jump height. Peak first toe flexor muscle strength and ankle dorsiflexion range of motion are the main contributors to countermovement jump performance. [Conclusion] These findings indicate that the measurement of peak first toe flexor muscle strength and ankle dorsiflexion range of motion may be useful in clinical practice for improving jump performance in athletes training for sports such as volleyball and basketball.

  8. Effects of implant material and plate design on tendon function and morphology.

    Science.gov (United States)

    Cohen, Mark S; Turner, Thomas M; Urban, Robert M

    2006-04-01

    Titanium implants are an alternative to stainless steel implants for internal fixation after fracture. The advantages of titanium include decreased implant stiffness, increased bio-compatibility, and diminished stress shielding. However, titanium has been implicated in tendon irritation and adhesions when used in the hand and wrist. We evaluated the relationship between extensor tendon morphology and dorsal plating of the distal radius in a canine model using distal radius pi plates made of stainless steel, titanium, and titanium alloy with a modified ramped edge design. We found marked histologic changes in the tendons and surrounding soft tissues including tendon deformation and degeneration (fibrillation, cartilage metaplasia, hypocellularity and hyalinization of blood vessels), peritendonous adhesions and neovascularity in the parenchyma. Only a minimal inflammatory cell infiltrate was identified and was limited to the tenosynovium and/or paratenon. No differences were identified between titanium and stainless steel implants and those with a ramped design. Although all animals lost wrist motion with time, no differences were observed between groups. Our results suggest that pi plate placement on the dorsal surface of the distal radius may lead to extensor tendon irritation and dysfunction. There is no evidence to suggest that this is specifically related to titanium or plate edge design.

  9. The prevalence of the extensor digiti minimi tendon of the hand and its variants in humans: a systematic review and meta-analysis.

    Science.gov (United States)

    Yammine, Kaissar

    2015-01-01

    The extensor digiti minimi (EDM) is frequently used in the case of an abduction deformity of the little finger. It is also considered as a main resource for tendon transfer. However, it shows many variations in the human hand, which include splitting into two or more slips and sending a slip to the fourth finger, named the extensor digiti minimi et quarti (EDMQ). The aim of this systematic review is to perform an evidence synthesis on the prevalence of the EDM and its variants. Twenty-six cadaveric studies met the inclusion criteria with a total of 2247 hands. Meta-analysis results yielded an overall pooled prevalence estimate (PPE) of the EDM of 99.7% and PPEs of 11.5, 77.6, 7 and 0.6% for the single-, double-, triple- and quadruple-slip EDM, respectively. For the single-slip EDM, the frequencies were such that Indians > Middle Eastern > Europeans > Japanese > North Americans. For the double-slip EDM, the frequencies were such that Japanese > North Americans = Europeans > Middle Eastern > Indians. No significance was found with regard to hand side. The true EDMQ prevalence was found to be at 7.3%, whereas its crude prevalence was 8%. This artilce offers reference values on the prevalence of the EDM and its variants, which are thought to be highly relevant to both anatomists and clinicians.

  10. Distal biceps brachii tendon repair: a systematic review of patient outcome determination using modified Coleman methodology score criteria.

    Science.gov (United States)

    Nyland, John; Causey, Brandon; Wera, Jeff; Krupp, Ryan; Tate, David; Gupta, Amit

    2017-07-01

    This systematic literature review evaluated the methodological research design quality of studies that evaluated patient outcomes following distal biceps brachii tendon repair and developed evidence-based recommendations for future patient clinical outcomes research. Following the preferred reporting items for systematic reviews and meta-analyses criteria, and using "biceps brachii", "tendon", "repair" and "outcome assessment" search terms, the CINAHL, Academic Search Premier and MEDLINE databases were searched from January 1960-October 2015. The modified Coleman methodology score (MCMS) served as the primary outcome measure. Descriptive statistical analysis was performed for composite and component MCMS and for patient outcome assessment methodology use frequency. A total of 93 studies were evaluated. Overall MCMS was low (57.1 ± 14). Only 12 (12.9 %) had prospective cohort or randomized controlled trial designs. There was a moderate relationship between publication year and MCMS (r = 0.53, P research study methodological scores improved on average since 2008, generally low MCMS scores, retrospective designs, lack of eccentric elbow flexor or supinator strength testing, and poorly described surgical and rehabilitation descriptions remain commonplace. These findings decrease clinical study validity and generalizability. III.

  11. Dupuytren’s disease digital radius IV right hand and carpal tunnel syndrome on ipsilateral hand

    Directory of Open Access Journals (Sweden)

    Teona Sebe Ioana

    2015-11-01

    , carpal ligament section, external neurolysis of the median nerve, flexor tendon tenolisys. The particularity of this case is the coexistence of two pathologies: Dupuytren’s disease and carpal tunnel syndrome, the decision to solve in the same operator time and the problem of immobilization. Reportation of this case supports previous reports in literature, such as Dupuytren’s disease and carpal tunnel syndrome are observed at the same patient, at the same time or one after another.

  12. Nomenclatural review of long digital forelimb flexors in carnivores.

    Science.gov (United States)

    Spoor, C F; Badoux, D M

    1986-12-01

    A hitherto-unknown atavistic muscle in the dog initiated a review of the literature on the homologies and nomenclature of the forelimb flexors in carnivores and man. A consequence is that we recommend a revision of the nomenclature in the Nomina Anatomica Veterinaria (Ithaca, New York, 1983) so that it is in agreement with the Nomina Anatomica (Wilkins, Baltimore, 1983). This revision mainly consists of the incorporation of the terms M. palmaris longus and Mm. flexores breves manus.

  13. Calcaneal tendon: imaging findings

    International Nuclear Information System (INIS)

    Montandon, Cristiano; Fonseca, Cristiano Rezio; Montandon Junior, Marcelo Eustaquio; Lobo, Leonardo Valadares; Ribeiro, Flavia Aparecida de Souza; Teixeira, Kim-Ir-Sen Santos

    2003-01-01

    We reviewed the radiological and clinical features of 23 patients with calcaneal tendon diseases, who were submitted to ultrasound or magnetic resonance imaging. The objective of this study was to characterize the lesions for a precise diagnosis of calcaneal tendon injuries. A wide range of calcaneal tendon diseases include degenerative lesions, inflammation of the peritendinous tissue such as peritendinitis and bursitis, and rupture. Imaging methods are essential in the diagnosis, treatment and follow-up of calcaneal tendon diseases. (author)

  14. Containment structure tendon investigation

    International Nuclear Information System (INIS)

    Fulton, J.F.; Murray, K.H.

    1983-01-01

    The paper describes an investigation into the possible causes of lower-than-predicted tendon forces which were measured during past tendon surveillances for a concrete containment. The containment is post tensioned by vertical tendons which are anchored into a rock foundation. The tendons were originally stressed in 1969, and lift-off tests were performed on six occasions subsequent to this date over a period of 11 years. The tendon forces measured in these tests were generally lower than predicted, and by 1979 the prestress level in the containment was only marginally above the design requirement. The tendons were retensioned in 1980, and by this time an investigation into the possible causes was underway. Potential causes investigated include the rock anchors and surrounding rock, elastomeric pad creep, wire stresses, thermal effects, stressing equipment and lift-off procedures, and wire stress relaxation. The investigation activities included stress relaxation testing of wires pulled from actual tendons. The stress relaxation test program included wire specimens at several different temperature and initial stress levels and the effect of a varying temperature history on the stress relaxation property of the wires. For purpose of future force predictions of the retensioned tendons, the test program included tests to determine the effect on stress relaxation due to restressing the wires after they had relaxed for 1000 hours and 10,000 hours. (orig./GL)

  15. Highly Unusual Tendon Abnormality: Spontaneous Rupture of the Distal Iliopsoas Tendon

    Directory of Open Access Journals (Sweden)

    Gokcen Coban

    2014-06-01

    Full Text Available Iliopsoas tendon injuries are not common and usually occur due to avulsion of the iliopsoas tendon with detachment of the lesser trochanter, secondary to an athletic injury or trauma. In the absence of a trauma, avulsion of the lesser trochanter in an adult is regarded as a sign of metastatic disease until proven otherwise. Complete iliopsoas tendon tears have thus far only been described in elderly women, and without trauma or an underlying systemic disease, a hormonal basis may be a reason for the gender differences. In this article, we present an 87-year-old woman with spontaneous rupture of the left distal iliopsoas tendon unassociated with fracture of the lesser trochanter and in the absence of a recent trauma history. This elderly patient presented with acute groin pain and normal plain radiographs. Magnetic resonance imaging must be kept in mind as a modality of choice for identifying iliopsoas tendon abnormalities.

  16. [Achilles tendon rupture].

    Science.gov (United States)

    Thermann, H; Hüfner, T; Tscherne, H

    2000-03-01

    The treatment of acute of Achilles tendon rupture experienced a dynamic development in the last ten years. Decisive for this development was the application of MRI and above all the ultrasonography in the diagnostics of the pathological changes and injuries of tendons. The question of rupture morphology as well as different courses of healing could be now evaluated objectively. These advances led consequently to new modalities in treatment concepts and rehabilitation protocols. The decisive input for improvements of the outcome results and particularly the shortening of the rehabilitation period came with introduction of the early functional treatment in contrast to immobilizing plaster treatment. In a prospective randomized study (1987-1989) at the Trauma Dept. of the Hannover Medical School could show no statistical differences comparing functional non-operative with functional operative therapy with a special therapy boot (Variostabil/Adidas). The crucial criteria for therapy selection results from the sonographically measured position of the tendon stumps in plantar flexion (20 degrees). With complete adaptation of the tendons' ends surgical treatment does not achieve better results than non-operative functional treatment in term of tendon healing and functional outcome. Regarding the current therapeutic standards each method has is advantages and disadvantages. Both, the operative and non-operative functional treatment enable a stable tendon healing with a low risk of re-rupture (1-2%). Meanwhile there is consensus for early functional after-treatment of the operated Achilles' tendons. There seems to be a trend towards non-operative functional treatment in cases of adequate sonographical findings, or to minimal invasive surgical techniques.

  17. Structural tendon changes in patients with acromegaly: assessment of Achilles tendon with sonoelastography.

    Science.gov (United States)

    Onal, Eda Demil; Ipek, Ali; Evranos, Berna; Idilman, Ilkay Sedakat; Cakir, Bekir; Ersoy, Reyhan

    2016-03-01

    To describe the sonoelastographic appearance of the Achilles tendon in acromegalic patients and to determine whether the blood concentrations of growth hormone (GH) and insulin-like growth factor (IGF-1) are associated with the various sonographic elasticity types of Achilles tendons. Eighty-four Achilles tendons of 42 acromegaly patients and 84 Achilles tendons of 42 healthy volunteers were assessed with sonoelastography. The tendons were classified into two main types according to the elasticity features: type 1 blue/green (hard tissue) and type 2 yellow/red within green (intermediate-soft tissue). Two subtypes of these types were also defined. According to the definition, the elasticity of the tissue was in a spectrum ranging from hard to soft as the type progressed from 1a to 2b. The mean thickness of Achilles tendons in patients with acromegaly was significantly higher compared with healthy Achilles tendons (5.1+/-0.7 mm vs. 4.4+/-0.5, pacromegaly patients had type 2 sonoelastographic appearance of the Achilles tendon (124/252 third; 49.2% vs. 81/252 third; 32.1%, p=0.0001). Activity status of acromegaly and GH/IGF-I levels were similar in patients with different types of elasticity (p>0.05). Sonoelastography revealed structural changes in the tendinous tissue of patients with acromegaly, but it was not sensitive enough to reflect changes in the serum levels of GH/IGF-1.

  18. Desequilíbrios musculares entre flexores dorsais e plantares do tornozelo após tratamento conservador e acelerado da ruptura do tendão calcâneo Muscle imbalance between ankle dorsiflexors and plantarflexors after conservative and accelerated treatment of Achilles tendon rupture

    Directory of Open Access Journals (Sweden)

    Alexandre Mayer

    2010-06-01

    Full Text Available A ruptura do tendão calcâneo (TC reduz a sobrecarga mecânica dos flexores plantares (FP do tornozelo. Essa alteração muda o equilíbrio natural entre os FP e flexores dorsais (FD do tornozelo. O objetivo do estudo foi avaliar as razões isocinéticas concêntricas convencionais de torque de pacientes submetidos a tratamento cirúrgico de ruptura aguda do TC após dois protocolos diferentes de reabilitação. Após procedimento cirúrgico para reconstrução do TC, a amostra foi dividida de forma intencional em dois grupos: conservador (GC, 11 homens, 41,3±7,9 anos e grupo acelerado (GA, 13 homens, 43,5±13,7 anos. O GC permaneceu com imobilização gessada no tornozelo por seis semanas (tratamento tradicional, enquanto o GA usou uma órtese robofoot em posição neutra e, após duas semanas, iniciou mobilização e apoio precoce do tornozelo, com reabilitação por seis semanas. Após 3 meses de pós-operatório, a razão do torque concêntrico máximo dos FD pelos FP do tornozelo foi avaliada por dinamômetro isocinético. As razões de torque do lado operado se mantiveram superiores às do lado saudável mesmo após 3 meses de pós-operatório (pAchilles tendon rupture reduces ankle plantarflexor (PF muscles mechanical overload. This change in the ankle joint mechanics changes the natural muscle balance between dorsiflexor (DF and PF muscles. The purpose of this study was to assess such imbalance by concentric conventional isokinetic torque ratios of patients who underwent different rehabilitation protocols after surgical repair of the Achilles tendon. After surgery, subjects were assigned to either a conservative or to an accelerated rehabilitation group. The conservative group (11 men, 41.3±7.9 years old remained with a plaster cast for 6 weeks after surgery. The accelerated group (13 men, 43.5±13,7 years old used a"robofoot" cast for 2 weeks and underwent ankle mobilization and early weight bearing for a period of 6 weeks post

  19. MRI of tibialis anterior tendon rupture

    International Nuclear Information System (INIS)

    Gallo, Robert A.; DeMeo, Patrick J.; Kolman, Brett H.; Daffner, Richard H.; Sciulli, Robert L.; Roberts, Catherine C.

    2004-01-01

    Ruptures of the tibialis anterior tendon are rare. We present the clinical histories and MRI findings of three recent male patients with tibialis anterior tendon rupture aged 58-67 years, all of whom presented with pain over the dorsum of the ankle. Two of the three patients presented with complete rupture showing discontinuity of the tendon, thickening of the retracted portion of the tendon, and excess fluid in the tendon sheath. One patient demonstrated a partial tear showing an attenuated tendon with increased surrounding fluid. Although rupture of the tibialis anterior tendon is a rarely reported entity, MRI is a useful modality in the definitive detection and characterization of tibialis anterior tendon ruptures. (orig.)

  20. Histological Changes in the Proximal and Distal Tendon Stumps Following Transection of Achilles Tendon in the Rabbits.

    Science.gov (United States)

    Al-Qattan, Mohammad M; Mawlana, Ola Helmi; Mohammed Ahmed, Raeesa Abdel-Twab; Hawary, Khalid

    2016-05-01

    To determine tendon stump changes following unrepaired Achilles tendon lacerations in an animal model. An experimental study. King Saud University, Riyadh, Saudi Arabia, from October 2013 to January 2014. Arabbit model was developed and studied tendon retraction and histological changes in the proximal and distal stumps following transection of the Achilles tendon. Over a period of 12 weeks, retraction of the distal tendon stump was minimal (2 - 3 mm). In contrast, retraction of the proximal tendon stump peaked to reach 6 mm at 4 weeks post-injury and plateaued to reach 7 - 8 mm at the 12-week interval. Following complete transection of the Achilles tendon, tendon retraction correlated with the density of myofibroblast expression within the tendon stump. Further research is needed to investigate the pathophysiology of these findings.

  1. Novel methods for tendon investigations

    DEFF Research Database (Denmark)

    Kjær, Michael; Langberg, Henning; Bojsen-Møller, J.

    2008-01-01

    Purpose. Tendon structures have been studied for decades, but over the last decade, methodological development and renewed interest for metabolic, circulatory and tissue protein turnover in tendon tissue has resulted in a rising amount of investigations. Method. This paper will detail the various...... modern investigative techniques available to study tendons. Results. There are a variety of investigative methods available to study the correlations between mechanics and biology in tendons. Conclusion. The available methodologies not only allow for potential insight into physiological...... and pathophysiological mechanisms in tendon tissue, but also, to some extent, allow for more elaborate studies of the intact human tendon. Read More: http://informahealthcare.com/doi/full/10.1080/09638280701785403...

  2. Rupture of the long tendon of the biceps brachi muscle. An unusual case related to use of the pneumatic tourniquet.

    Science.gov (United States)

    Logel, R J

    1976-01-01

    Tourniquet paralysis, arterial spasm, aneurysm formation, and the post-ischemic hand syndrome are all complications of penumatic tourniquet use in surgery of the extremities. This is a case report of another complication of tourniquet use, rupture of the long tendon of the biceps brachii muscle. Some underlying pathologic or degenerative condition usually exists before rupture can occur. Both rheumatoid arthritis and local corticosteroid injections into the long tendon of the biceps probably accounted for weakening the tensile strength of the tendon and subsequent rupture in the case described.

  3. A case report of vibration-induced hand comorbidities in a postwoman

    Directory of Open Access Journals (Sweden)

    Violante Francesco S

    2011-02-01

    Full Text Available Abstract Background Prolonged exposure to hand-transmitted vibration is associated with an increased occurrence of symptoms and signs of disorders in the vascular, neurological and osteoarticular systems of the upper limbs. However, the available epidemiological evidence is derived from studies on high vibration levels caused by vibratory tools, whereas little is known about possible upper limb disorders caused by chronic exposure to low vibration levels emitted by fixed sources. Case presentation We present the case of a postwoman who delivered mail for 15 years using a low-powered motorcycle. The woman was in good health until 2002, when she was diagnosed with bilateral Raynaud's phenomenon. In March 2003 a bilateral carpal tunnel syndrome was electromyographically diagnosed; surgical treatment was ineffective. Further examinations in 2005 highlighted the presence of chronic tendonitis (right middle finger flexor. Risk assessment From 1987, for 15 years, our patient rode her motorcycle for 4 h/day, carrying a load of 20-30 kg. For about a quarter of the time she drove over country roads. Using the information collected about the tasks carried out every day by the postwoman and some measurements performed on both handles of the motorcycle, as well as on both iron parts of the handlebars, we reconstructed the woman's previous exposure to hand-arm vibration. 8-hour energy-equivalent frequency weighted acceleration was about 2.4 m/s2. The lifetime dose was 1.5 × 109(m2/s4hd. Conclusions The particular set of comorbidities presented by our patient suggests a common pathophysiological basis for all the diseases. Considering the level of exposure to vibrations and the lack of specific knowledge on the effects of vibration in women, we hypothesize an association between the work exposure and the onset of the diseases.

  4. Histological Changes in the Proximal and Distal Tendon Stumps Following Transection of Achilles Tendon in the Rabbits

    International Nuclear Information System (INIS)

    Al-Qattan, M. M.; Hawary, K.; Mawlana, O. H.; Ahmed, R. A. M.

    2016-01-01

    Objective: To determine tendon stump changes following unrepaired Achilles tendon lacerations in an animal model. Study Design: An experimental study. Place and Duration of Study: King Saud University, Riyadh, Saudi Arabia, from October 2013 to January 2014. Methodology: Arabbit model was developed and studied tendon retraction and histological changes in the proximal and distal stumps following transection of the Achilles tendon. Result: Over a period of 12 weeks, retraction of the distal tendon stump was minimal (2 - 3 mm). In contrast, retraction of the proximal tendon stump peaked to reach 6 mm at 4 weeks post-injury and plateaued to reach 7 - 8 mm at the 12-week interval. Conclusion: Following complete transection of the Achilles tendon, tendon retraction correlated with the density of myofibroblast expression within the tendon stump. Further research is needed to investigate the pathophysiology of these findings. (author)

  5. Sex Hormones and Tendon

    DEFF Research Database (Denmark)

    Hansen, Mette; Kjaer, Michael

    2016-01-01

    The risk of overuse and traumatic tendon and ligament injuries differ between women and men. Part of this gender difference in injury risk is probably explained by sex hormonal differences which are specifically distinct during the sexual maturation in the teenage years and during young adulthood....... The effects of the separate sex hormones are not fully elucidated. However, in women, the presence of estrogen in contrast to very low estrogen levels may be beneficial during regular loading of the tissue or during recovering after an injury, as estrogen can enhance tendon collagen synthesis rate. Yet...... has also been linked to a reduced responsiveness to relaxin. The present chapter will focus on sex difference in tendon injury risk, tendon morphology and tendon collagen turnover, but also on the specific effects of estrogen and androgens....

  6. Measurement of Gender Differences of Gastrocnemius Muscle and Tendon Using Sonomyography during Calf Raises: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Guang-Quan Zhou

    2017-01-01

    Full Text Available Skeletal muscles are essential to the gender-specific characteristics of human movements. Sonomyography, a new signal for quantifying muscle activation, is of great benefit to understand muscle function through monitoring the real-time muscle architectural changes. The purpose of this pilot study was to investigate gender differences in the architectural changes of gastronomies muscle and tendon by using sonomyography during performing two-legged calf raising exercises. A motion analysis system was developed to extract sonomyography from ultrasound images together with kinematic and kinetic measurements. Tiny fascicle length changes among seven male subjects were observed at the initial part of calf raising, whereas the fascicle of seven female subjects shortened immediately. This result suggested that men would generate higher mechanical power output of plantar flexors to regulate their heavier body mass. In addition, the larger regression coefficient between the fascicle length and muscle force for the male subjects implied that higher muscle stiffness for the men was required in demand of maintaining their heavier body economically. The findings from the current study suggested that the body mass might play a factor in the gender difference in structural changes of muscle and tendon during motion. The sonomyography may provide valuable information in the understanding of the gender difference in human movements.

  7. Recovery Kinetics of Knee Flexor and Extensor Strength after a Football Match

    Science.gov (United States)

    Draganidis, Dimitrios; Chatzinikolaou, Athanasios; Avloniti, Alexandra; Barbero-Álvarez, José C.; Mohr, Magni; Malliou, Paraskevi; Gourgoulis, Vassilios; Deli, Chariklia K.; Douroudos, Ioannis I.; Margonis, Konstantinos; Gioftsidou, Asimenia; Fouris, Andreas D.; Jamurtas, Athanasios Z.; Koutedakis, Yiannis; Fatouros, Ioannis G.

    2015-01-01

    We examined the temporal changes of isokinetic strength performance of knee flexor (KF) and extensor (KE) strength after a football match. Players were randomly assigned to a control (N = 14, participated only in measurements and practices) or an experimental group (N = 20, participated also in a football match). Participants trained daily during the two days after the match. Match and training overload was monitored with GPS devices. Venous blood was sampled and muscle damage was assessed pre-match, post-match and at 12h, 36h and 60h post-match. Isometric strength as well as eccentric and concentric peak torque of knee flexors and extensors in both limbs (dominant and non-dominant) were measured on an isokinetic dynamometer at baseline and at 12h, 36h and 60h after the match. Functional (KFecc/KEcon) and conventional (KFcon/KEcon) ratios were then calculated. Only eccentric peak torque of knee flexors declined at 60h after the match in the control group. In the experimental group: a) isometric strength of knee extensors and knee flexors declined (Pfootball-specific conditioning. Our data suggest that recovery kinetics of knee flexor and extensor strength after a football match demonstrate strength, limb and velocity specificity and may depend on match physical overload and players' physical conditioning level. PMID:26043222

  8. Changes in Achilles tendon mechanical properties following eccentric heel drop exercise are specific to the free tendon.

    Science.gov (United States)

    Obst, S J; Newsham-West, R; Barrett, R S

    2016-04-01

    Mechanical loading of the Achilles tendon during isolated eccentric contractions could induce immediate and region-dependent changes in mechanical properties. Three-dimensional ultrasound was used to examine the immediate effect of isolated eccentric exercise on the mechanical properties of the distal (free tendon) and proximal (gastrocnemii) regions of the Achilles tendon. Participants (n = 14) underwent two testing sessions in which tendon measurements were made at rest and during a 30% and 70% isometric plantar flexion contractions immediately before and after either: (a) 3 × 15 eccentric heel drops or (b) 10-min rest. There was a significant time-by-session interaction for free tendon length and strain for all loading conditions (P tendon length and strain at all contraction intensities after eccentric exercise (P tendon for any of the measured parameters. Immediate changes in Achilles tendon mechanical properties were specific to the free tendon and consistent with changes due to mechanical creep. These findings suggest that the mechanical properties of the free tendon may be more vulnerable to change with exercise compared with the gastrocnemii aponeurosis or tendon. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Radiographic anatomy of soft tissue attachments in the equine metacarpophalangeal and proximal phalangeal region

    International Nuclear Information System (INIS)

    Weaver, J.C.B.; Stover, S.M.; O'Brien, T.R.

    1992-01-01

    The sites of bony attachment of the tendons, ligaments, and fibrous portion of the joint capsules of the equine metacarpophalangeal (fetlock) joint region were determined by gross dissection. These sites were transposed to standard radiographic views of the fetlock joint to yield illustrations that can be used as an aid in the diagnosis of soft tissue pathology from radiographs. Evidence of direct attachment of the common digital extensor tendon to the proximal phalanx was not found. Branches of the superficial digital flexor tendon were found to insert only on the middle phalanx. The recently described sites of insertion of the branches of the superficial digital flexor tendon to the proximal phalanx were found to be sites for attachment of the deep axial palmar ligaments of the proximal interphalangeal joint

  10. Effect of strength training on regional hypertrophy of the elbow flexor muscles.

    Science.gov (United States)

    Drummond, Marcos D M; Szmuchrowski, Leszek A; Goulart, Karine N O; Couto, Bruno P

    2016-10-01

    Muscle hypertrophy is the main structural adaptation to strength training. We investigated the chronic effects of strength training on muscle hypertrophy in different regions of the elbow flexor muscles. Eleven untrained men (21.8 ± 1.62 years) underwent magnetic resonance imaging to determine the proximal, medial, distal, and mean cross-sectional areas (CSA) of the elbow flexors. The volunteers completed 12 weeks of strength training. The training protocol consisted of 4 sets of 8-10 maximum repetitions of unilateral elbow flexion. The interval between sets was 120 s. The training frequency was 3 sessions per week. The magnetic resonance images verified the presence of significant and similar hypertrophy in the distal, medial, and proximal portions of the elbow flexor muscles. Muscle hypertrophy may be assessed using only the medial CSA. We should not expect different degrees of hypertrophy among the regions of the elbow flexor muscles. Muscle Nerve 54: 750-755, 2016. © 2016 Wiley Periodicals, Inc.

  11. EFFECT OF UNIPOLAR ACU-STIM ON MUSCLE RE-EDUCATION FOLLOWING TENDON TRANSFER - A CASE STUDY

    Directory of Open Access Journals (Sweden)

    Prof. Srikanth R

    2015-02-01

    Full Text Available Background: Tendon transfer surgery is usually done to improve function, following damage to either major nerve trunks or peripheral nerves. Re-education of the muscle is of utmost importance to gain functional activity.To achieve this, along with re-education exercises, faradic stimulation is usually used. Unipolar Acu-Stim (UAS, is an innovative technique where an acupuncture needle is used to stimulate the transferred tendon with Surged Faradic Currents (SFC. The objective of the study is to identify if the application of SFC using UAS method, is effective to re-educate a transferred muscle. Case Description: The subject was a 24 year old male who had a loss of finger and thumb extension following Posterior Interosseous Nerve (PIN palsy, for which Flexor Carpi Radialis (FCR was transferred to Extensor Digitorum Communis (EDC and Palmaris Longus (PL was transferred to Extensor Pollicis Longus (EPL. Following removal of the POP, UAS with surged faradic current was applied for 4 weeks along with re-education exercises. Prognosis of finger extension was assessed by goniometry and video recordings. Outcome: At the end of 8th week, as observed on goniometry and video recordings, complete finger extension was achieved. Discussion: UAS with SFC, is useful in re-education of a transferred muscle, as desired movement can be achieved with low intensity.

  12. Development of anthropomorphic robotic hand driven by Pneumatic Artificial Muscles for robotic applications

    Science.gov (United States)

    Farag, Mohannad; Zainul Azlan, Norsinnira; Hayyan Alsibai, Mohammed

    2018-04-01

    This paper presents the design and fabrication of a three-fingered anthropomorphic robotic hand. The fingers are driven by tendons and actuated by human muscle-like actuators known as Pneumatic Artificial Muscle (PAM). The proposed design allows the actuators to be mounted outside the hand where each finger can be driven by one PAM actuator and six indirectly interlinked tendons. With this design, the three-fingered hand has a compact size and a lightweight with a mass of 150.25 grams imitating the human being hand in terms of size and weight. The hand also successfully grasped objects with different shapes and weights up to 500 g. Even though the number of PAM actuators equals the number of Degrees of Freedom (DOF), the design guarantees driving of three joints by only one actuator reducing the number of required actuators from 3 to 1. Therefore, this hand is suitable for researches of robotic applications in terms of design, cost and ability to be equipped with several types of sensors.

  13. Sports Injury-Related Fingers and Thumb Deformity Due to Tendon or Ligament Rupture

    Directory of Open Access Journals (Sweden)

    Rong-Jie Bai

    2018-01-01

    Conclusions: Sports injury-related fingers and thumb deformity are relatively common. MRI is an accurate method for evaluation of the anatomy and pathologic conditions of the fingers and thumb. It is a useful tool for accurate diagnosis of the sports-related ligaments and tendons injuries in hand.

  14. Osteocalcin expressing cells from tendon sheaths in mice contribute to tendon repair by activating Hedgehog signaling

    OpenAIRE

    Wang, Yi; Zhang, Xu; Huang, Huihui; Xia, Yin; Yao, YiFei; Mak, Arthur Fuk-Tat; Yung, Patrick Shu-Hang; Chan, Kai-Ming; Wang, Li; Zhang, Chenglin; Huang, Yu; Mak, Kingston King-Lun

    2017-01-01

    Both extrinsic and intrinsic tissues contribute to tendon repair, but the origin and molecular functions of extrinsic tissues in tendon repair are not fully understood. Here we show that tendon sheath cells harbor stem/progenitor cell properties and contribute to tendon repair by activating Hedgehog signaling. We found that Osteocalcin (Bglap) can be used as an adult tendon-sheath-specific marker in mice. Lineage tracing experiments show that Bglap-expressing cells in adult sheath tissues pos...

  15. Bioreactor Design for Tendon/Ligament Engineering

    OpenAIRE

    Wang, Tao; Gardiner, Bruce S.; Lin, Zhen; Rubenson, Jonas; Kirk, Thomas B.; Wang, Allan; Xu, Jiake; Smith, David W.; Lloyd, David G.; Zheng, Ming H.

    2012-01-01

    Tendon and ligament injury is a worldwide health problem, but the treatment options remain limited. Tendon and ligament engineering might provide an alternative tissue source for the surgical replacement of injured tendon. A bioreactor provides a controllable environment enabling the systematic study of specific biological, biochemical, and biomechanical requirements to design and manufacture engineered tendon/ligament tissue. Furthermore, the tendon/ligament bioreactor system can provide a s...

  16. The differential effects of leukocyte-containing and pure platelet-rich plasma (PRP) on tendon stem/progenitor cells - implications of PRP application for the clinical treatment of tendon injuries.

    Science.gov (United States)

    Zhou, Yiqin; Zhang, Jianying; Wu, Haishan; Hogan, MaCalus V; Wang, James H-C

    2015-09-15

    Platelet-rich plasma (PRP) is widely used to treat tendon injuries in clinics. These PRP preparations often contain white blood cells or leukocytes, and the precise cellular effects of leukocyte-rich PRP (L-PRP) on tendons are not well defined. Therefore, in this study, we determined the effects of L-PRP on tendon stem/progenitor cells (TSCs), which play a key role in tendon homeostasis and repair. TSCs isolated from the patellar tendons of rabbits were treated with L-PRP or P-PRP (pure PRP without leukocytes) in vitro, followed by measuring cell proliferation, stem cell marker expression, inflammatory gene expression, and anabolic and catabolic protein expression by using immunostaining, quantitative real-time polymerase chain reaction, Western blot, and enzyme-linked immunosorbent assay, respectively. Cell proliferation was induced by both L-PRP and P-PRP in a dose-dependent manner with maximum proliferation at a 10 % PRP dose. Both PRP treatments also induced differentiation of TSCs into active tenocytes. Nevertheless, the two types of PRP largely differed in several effects exerted on TSCs. L-PRP induced predominantly catabolic and inflammatory changes in differentiated tenocytes; its treatment increased the expression of catabolic marker genes, matrix metalloproteinase-1 (MMP-1), MMP-13, interleukin-1beta (IL-1β), IL-6 and tumor necrosis factor-alpha (TNF-α), and their respective protein expression and prostaglandin E2 (PGE 2) production. In contrast, P-PRP mainly induced anabolic changes; that is, P-PRP increased the gene expression of anabolic genes, alpha-smooth muscle actin (α-SMA), collagen types I and III. These findings indicate that, while both L-PRP and P-PRP appear to be "safe" in inducing TSC differentiation into active tenocytes, L-PRP may be detrimental to the healing of injured tendons because it induces catabolic and inflammatory effects on tendon cells and may prolong the effects in healing tendons. On the other hand, when P-PRP is used to

  17. Small hook thread (Quill) and soft felt internal splint to increase the primary repair strength of lacerated rabbit Achilles tendons: biomechanical analysis and considerations for hand surgery.

    Science.gov (United States)

    Buschmann, Johanna; Müller, Angela; Feldman, Kirill; Tervoort, Theo A; Fessel, Gion; Snedeker, Jess G; Giovanoli, Pietro; Calcagni, Maurizio

    2011-07-01

    For the prevention of re-rupture during early healing phase, the primary repair strength of repaired lacerated tendons in hand surgery should be maximal and the reconstructed diameter minimal. Two new repair methods (small hook thread and internal splint) were assessed for strength and reconstructed diameter characteristics. Achilles tendons of 43 female New Zealand White rabbits were sectioned 2 cm above the calcaneus. Specimens were divided into 7 groups and repaired as follows: Kirchmayr method 2-strand with 4.0 polypropylene thread; Becker method 4-strand; 6-strand; internal splint; Kirchmayr method small hook 2-strand; Becker method small hook 4-strand, non-modified tendon. Load until failure, load until gap formation, gap length, cross-sectional area and failure stress were determined. The small hook 2-strand suture had 1.3 fold higher loads until failure compared to a conventional 2-strand suture, P<0.05. The internal splint had a similar load until failure (22 N (SD 6)) as the conventional 2-strand suture (23 N (SD 4)); around half the load until failure of the conventional 4-strand suture (38 N (SD 9)). Load until gap formation correlated positively with load until failure (y=0.65+3.6; r(2)=0.72). The running suture increased the cross-sectional area at the repair site by a factor of 1.3. Using a small hook thread instead of a 4.0 polypropylene thread significantly increases the primary repair strength with the same number of strands. Internal splints may be an alternative to conventional 2-strand sutures for bridging large gaps. Copyright © 2011 Elsevier Ltd. All rights reserved.

  18. Changes in histoanatomical distribution of types I, III and V collagen promote adaptative remodeling in posterior tibial tendon rupture

    Directory of Open Access Journals (Sweden)

    Érika Satomi

    2008-01-01

    Full Text Available INTRODUCTION: Posterior tibial tendon dysfunction is a common cause of adult flat foot deformity, and its etiology is unknown. PURPOSE: In this study, we characterized the morphologic pattern and distribution of types I, III and V collagen in posterior tibial tendon dysfunction. METHOD: Tendon samples from patients with and without posterior tibial tendon dysfunction were stained by immunofluorescence using antibodies against types I, III and V collagen. RESULTS: Control samples showed that type V deposited near the vessels only, while surgically obtained specimens displayed type V collagen surrounding other types of collagen fibers in thicker adventitial layers. Type III collagen levels were also increased in pathological specimens. On the other hand, amounts of collagen type I, which represents 95% of the total collagen amount in normal tendon, were decreased in pathological specimens. CONCLUSION: Fibrillogenesis in posterior tibial tendon dysfunction is altered due to higher expression of types III and V collagen and a decreased amount of collagen type I, which renders the originating fibrils structurally less resistant to mechanical forces.

  19. Magnetotherapy: The quest for tendon regeneration.

    Science.gov (United States)

    Pesqueira, Tamagno; Costa-Almeida, Raquel; Gomes, Manuela E

    2018-05-09

    Tendons are mechanosensitive tissues that connect and transmit the forces generated by muscles to bones by allowing the conversion of mechanical input into biochemical signals. These physical forces perform the fundamental work of preserving tendon homeostasis assuring body movements. However, overloading causes tissue injuries, which leads us to the field of tendon regeneration. Recently published reviews have broadly shown the use of biomaterials and different strategies to attain tendon regeneration. In this review, our focus is the use of magnetic fields as an alternative therapy, which has demonstrated clinical relevance in tendon medicine because of their ability to modulate cell fate. Yet the underlying cellular and molecular mechanisms still need to be elucidated. While providing a brief outlook about specific signalling pathways and intracellular messengers as framework in play by tendon cells, application of magnetic fields as a subcategory of physical forces is explored, opening up a compelling avenue to enhance tendon regeneration. We outline here useful insights on the effects of magnetic fields both at in vitro and in vivo levels, particularly on the expression of tendon genes and inflammatory cytokines, ultimately involved in tendon regeneration. Subsequently, the potential of using magnetically responsive biomaterials in tendon tissue engineering is highlighted and future directions in magnetotherapy are discussed. © 2018 Wiley Periodicals, Inc.

  20. Ultrasonographic investigation of the Achilles tendon in elite badminton players using color Doppler.

    Science.gov (United States)

    Boesen, Morten Ilum; Boesen, Anders; Koenig, Merete Juhl; Bliddal, Henning; Torp-Pedersen, Soren

    2006-12-01

    The most frequent injuries in badminton players are in the lower extremities, especially in the Achilles tendon. The game of badminton may be related to abnormal intratendinous flow in the Achilles tendon as detected by color Doppler ultrasound. To a certain extent, this blood flow might be physiological, especially when examined after match. Cohort study (prevalence); Level of evidence, 3. Seventy-two elite badminton players were interviewed regarding Achilles tendon pain (achillodynia) in the preceding 3 years. Color Doppler was used to examine the tendons of 64 players before their matches and 46 players after their matches. Intratendinous color Doppler flow was graded from 0 to 4. The Achilles tendon was divided into dominant (eg, right side for right-handed players and vice versa) and nondominant side and classified as midtendon, preinsertional, and calcaneal areas. Of 72 players, 26 had experienced achillodynia in 34 tendons, 18 on the dominant side and 16 on the nondominant side. In 62% of the players with achillodynia, the problems had begun slowly, and the median duration of symptoms was 4 months (range, 0-36 months). Thirty-five percent had ongoing pain in their tendons for a median duration of 12 months (range, 0-12 months). Achillodynia was not associated with the self-reported training load or with sex, age, weight, singles or doubles players, or racket side. Forty-six players were scanned before and after match. At baseline, color Doppler flow was present in the majority of players, and only 7 (16%) players had no color Doppler flow in either tendon. After match, all players had some color Doppler flow in 1 or both tendons. Achillodynia and color Doppler flow were related in the nondominant Achilles tendon (chi-square, P = .008). The grades of Doppler flow also increased significantly after match in the preinsertional area in both the nondominant (P = .0002) and dominant (P = .005) side tendons. A large proportion of the players had experienced

  1. An investigation into the depth of penetration of low level laser therapy through the equine tendon in vivo

    Directory of Open Access Journals (Sweden)

    Ryan Teresa

    2007-05-01

    Full Text Available Abstract Low level laser therapy (LLLT is frequently used in the treatment of wounds, soft tissue injury and in pain management. The exact penetration depth of LLLT in human tissue remains unspecified. Similar uncertainty regarding penetration depth arises in treating animals. This study was designed to test the hypothesis that transmission of LLLT in horses is increased by clipping the hair and/or by cleaning the area to be treated with alcohol, but is unaffected by coat colour. A LLLT probe (810 nm, 500 mW was applied to the medial aspect of the superficial flexor tendon of seventeen equine forelimbs in vivo. A light sensor was applied to the lateral aspect, directly opposite the laser probe to measure the amount of light transmitted. Light transmission was not affected by individual horse, coat colour or leg. However, it was associated with leg condition (F = 4.42, p = 0.0032. Tendons clipped dry and clipped and cleaned with alcohol, were both associated with greater transmission of light than the unprepared state. Use of alcohol without clipping was not associated with an increase in light transmission. These results suggest that, when applying laser to a subcutaneous structure in the horse, the area should be clipped and cleaned beforehand.

  2. [Experience in using xeomin in the treatment of arm and hand spasticity in the early rehabilitation phase of stroke].

    Science.gov (United States)

    Kostenko, E V; Petrova, L V; Ganzhula, P A; Lisenker, L N; Otcheskaia, O V; Khozova, A A; Boĭko, A N

    2012-01-01

    To reduce arm and hand spasticity, 28 patients in the early rehabilitation phase of ischemic hemisphere stroke received injections of the botulinum toxin A preparation xeomin in the content of complex rehabilitation programs. The following muscles: m. biceps brachii, m. flexor digitorum profundus, m. flexor digitorum superficialis, m. flexor carpi ulnaris, m. flexor carpi radialis were injected according to standard scheme. The total dose of drug was 200U in moderate (2-3 scores on the Ashworth scale) and 300U in marked (3-4 scores on the Ashworth scale) spasticity. Efficacy and safety of treatment was assessed at baseline and 2, 4, 8, 12, 16 weeks after injections. Xeomin significantly (parm (due to patient's and caregiver's reports) remained for to 12 weeks. The treatment was most effective in the group of patients with moderate spasticity. The correlation analysis confirmed that the severity of spasticity increased with the disease duration that reduced rehabilitation efficiency. The treatment with xeomin was safe, no serious side-effects were found.

  3. Achilles Tendon's Tear

    OpenAIRE

    F. Shahandeh

    2008-01-01

    Introduction: The achilles and plantaris tendons to-gether makeup the posterior grouptendons of ankle. Their seldom confusion in interpreting MR images of the achilles tendon. The achilles tendon should ap-pear informally straight and black on sagital T1 weighted images and on fluid sensitive images."nCase Presentation: After a heavy sport, a 55 year-old woman cannot walk with right foot."nDiscussion: The classic achilles tendon rupture occurs with forced dorsiflexion of planted foo...

  4. Bioreactor design for tendon/ligament engineering.

    Science.gov (United States)

    Wang, Tao; Gardiner, Bruce S; Lin, Zhen; Rubenson, Jonas; Kirk, Thomas B; Wang, Allan; Xu, Jiake; Smith, David W; Lloyd, David G; Zheng, Ming H

    2013-04-01

    Tendon and ligament injury is a worldwide health problem, but the treatment options remain limited. Tendon and ligament engineering might provide an alternative tissue source for the surgical replacement of injured tendon. A bioreactor provides a controllable environment enabling the systematic study of specific biological, biochemical, and biomechanical requirements to design and manufacture engineered tendon/ligament tissue. Furthermore, the tendon/ligament bioreactor system can provide a suitable culture environment, which mimics the dynamics of the in vivo environment for tendon/ligament maturation. For clinical settings, bioreactors also have the advantages of less-contamination risk, high reproducibility of cell propagation by minimizing manual operation, and a consistent end product. In this review, we identify the key components, design preferences, and criteria that are required for the development of an ideal bioreactor for engineering tendons and ligaments.

  5. Reconstrução do LCA com o uso dos tendões dos músculos flexores mediais do joelho e fixação femoral com o sistema de Rigidifix®: relato preliminar Anterior cruciate ligament reconstruction using double hamstrings tendon graft and the femoral fixation by Rigidifix®: preliminary Study

    Directory of Open Access Journals (Sweden)

    Carlos Alberto Cury Faustino

    2004-12-01

    Full Text Available O autor descreve a técnica de reconstrução do LCA no tratamento das instabilidades anterior do joelho, utilizando os tendões dos músculos flexores mediais do joelho (semitendíneo e grácil, fixados no fêmur pelo sistema de Rigidfix®; e na tíbia, com parafuso de interferência absorvível, através de um estudo preliminar de 54 joelhos operados. Na avaliação final pela escala de Lysholm os pacientes evoluíram de 46 pontos no pré-operatório para 92 pontos no pós-operatório.The author describes the reconstruction technique of the anterior cruciate ligament reconstruction using the hamstrings tendon (semitendinosus and gracilis in the management of anterior instabilities of the knee joint. Rigidfix® system is used to fix the graft on the femur and an absorbable interference screw was used for tibial fixation in a preliminary study in 54 knees. The final evaluation based on Lysholm score showed an improvement from 46 (preoperative to 92 (postoperative.

  6. Evaluation of finger A3 pulley rupture in the crimp grip position - a magnetic resonance imaging cadaver study

    Energy Technology Data Exchange (ETDEWEB)

    Bayer, Thomas; Uder, Michael; Janka, Rolf [University of Erlangen-Nuremberg, Department of Radiology, Erlangen (Germany); Adler, Werner [University of Erlangen-Nuremberg, Department of Biometry and Epidemiology, Erlangen (Germany); Schweizer, Andreas [Balgrist, University of Zurich, Department of Orthopaedics, Zurich (Switzerland); Schoeffl, Isabelle [Klinikum Bamberg, Department of Pediatrics, Bamberg (Germany)

    2015-09-15

    The correct diagnosis of an A3 pulley rupture is challenging for musculoskeletal radiologists. An A3 pulley rupture should in theory influence the shape of the proximal interphalangeal joint volar plate (VP) and the amount of bowstringing at level of the VP during finger flexion. The purpose of this study was to perform MRI with metric analysis of the VP configuration and VP bowstringing in cadaver fingers in the crimp grip position and to determine cut points for A3 pulley rupture. MRI in the crimp grip position was performed in 21 cadaver fingers with artificially created flexor tendon pulley tears (fingers with A3 pulley rupture n = 16, fingers without A3 pulley rupture n = 5). The distances of the translation of the VP relative to the middle phalanx base, the distances between the flexor tendons and the VP body, and the distances between the flexor tendon and bone (TB) were measured. Statistical analysis showed significantly lower VP translation distances and significantly higher VP tendon distances if the A3 pulley was ruptured. A2 TB and A4 TB distances did not differ significantly in specimens with and without A3 pulley rupture. The optimal cut points for A3 pulley rupture were a VP translation distance <2.8 mm and a VP tendon distance >1.4 mm. Reduction of the VP translation distance and augmentation of the VP tendon distance are suitable indirect signs of A3 pulley rupture. (orig.)

  7. Optimal arm posture control and tendon traction forces of a coupled tendon-driven manipulator

    International Nuclear Information System (INIS)

    Ma, Shugen

    1997-01-01

    In this study, the optimum arm posture of a coupled tendon-driven multijoint manipulator arm (or CT Arm) at maximum payload output was derived and the corresponding tendon traction forces were also analyzed, during management of a heavy payload by the manipulator in a gravity environment. The CT Arm is special tendon traction transmission mechanism in which a pair of tendons used to drive a joint is pulled from base actuators via pulleys mounted on the base-side joints. This mechanism enables optimal utilization of the coupled drive function of tendon traction forces and thus enables the lightweight manipulator to exhibit large payload capability. The properties of the CT Arm mechanism are elucidated by the proposed optimal posture control scheme. Computer simulation was also executed to verify the validity of the proposed control scheme. (author)

  8. The Effect of Sodium Hyaluronate on Ligamentation and Biomechanical Property of Tendon in Repair of Achilles Tendon Defect with Polyethylene Terephthalate Artificial Ligament: A Rabbit Tendon Repair Model

    OpenAIRE

    Li, Shengkun; Ma, Kui; Li, Hong; Jiang, Jia; Chen, Shiyi

    2016-01-01

    The Achilles tendon is the most common ruptured tendon of human body. Reconstruction with polyethylene terephthalate (PET) artificial ligament is recommended in some serious cases. Sodium hyaluronate (HA) is beneficial for the healing of tendon injuries. We aimed to determine the effect of sodium hyaluronate in repair of Achilles tendon defect with PET artificial ligament in an animal tendon repair model. Sixteen New Zealand White rabbits were divided into two groups. Eight rabbits repaired w...

  9. The effects of cold immersion and hand protection on grip strength.

    Science.gov (United States)

    Vincent, M J; Tipton, M J

    1988-08-01

    The maximal voluntary grip strength (MVGS) of male volunteers was examined following a series of five intermittent 2 min cold water (5 degrees C) immersions of the unprotected hand or forearm. MVGS changes due to wearing a protective glove were also investigated. The surface electrical activity over the hand flexor muscles was recorded, as was the skin temperature of the hand and forearm. MVGS decreased significantly (p less than 0.01) following hand immersions (16%) and forearm immersion (13%). The majority of these reductions occurred during the first 2-min period of immersion. The effect of wearing a glove after unprotected hand cooling also produced significant (p less than 0.01) MVGS reductions which averaged 14%. These reductions were in addition to those caused by hand cooling. We conclude that both hand and forearm protection are important for the maintenance of hand-grip strength following cold water immersion.

  10. Radiographic/morphologic investigation of a radiolucent crescent within the flexor central eminence of the navicular bone in Thoroughbreds

    International Nuclear Information System (INIS)

    Berry, C.R.; Pool, R.R.; Stover, S.; O'Brien, T.R.; Koblik, P.D.

    1992-01-01

    The source of a previously described radiolucent crescent in the flexor cortex of the distal sesamoid (navicular) bone on the palmaro45 degrees proximal-palmarodistal oblique (Pa45 degrees Pr-PaDio) clinical radiographic projection was investigated in 48 forelimb navicular bones from 24 Thoroughbreds by use of high-detail radiography and x-ray computed tomography (CT). Twenty-five of these bones also were evaluated, using microradiography and histologic examinations. Of these 25 bones, 5 had been labeled in vivo with fluorochrome markers. Tetrachrome-stained 100-microns-thick nondecalcified sections of these 5 bones were examined, using epifluorescence microscopy. A reinforcement line of compacted cancellous bone, parallel and several millimeters deep to the flexor cortex in the region of the flexor central eminence, was visualized by CT in 42 of 48 navicular bones and by microradiography in 23 of 25 navicular bones investigated. Variable degrees of compaction were observed in the cancellous bone between the flexor cortex and the reinforcement line. High-detail skyline radiographic projections and reconstructed CT images indicated a crescent-shaped lucency within the flexor central eminence of the flexor cortex in the bones in which the reinforcement line was identified, but the cancellous bone between the reinforcement line and the flexor cortex had not been compacted. The radiolucent crescent seen in the flexor central eminence of the navicular bone on the Pa45 degrees Pr-PaDiO projection was not caused by the concave defect or synovial fossa of the flexor central eminence overlying the flexor cortex, as was described

  11. High-field MR imaging of the tendons

    International Nuclear Information System (INIS)

    Beltran, J.; Burk, J.M.; Herman, L.J.; Mosure, J.C.

    1987-01-01

    MR imaging was used to investigate normal anatomy and pathologic conditions of the tendons. Tendons of experimental animals, cadaver joints, normal volunteers, and patients with suspected tendon pathology were studied. Tendon anatomy is easily identified because of the hypointensity of the tendons contrasting with the hyperintendensity of the surrounding fat. Pathologic conditions including posttraumatic and postsurgical tendon rupture, peritendinous scarring, tendinitis, and tenosynovitis are well seen with MR imaging. A detailed study of normal and abnormal tendon anatomy of the finger, wrist, shoulder, knee, and ankle is displayed, including MR images, gross specimens, and line drawings

  12. Clinical aspects of tendon healing

    NARCIS (Netherlands)

    J.C.H.M. van der Meulen (Jacques)

    1974-01-01

    textabstractWe know that healing of a tendon wound takes place by an invasion of fibreblasts from the surrounding tissues; the tendon itself has no intrinsic healing capacity. lt was Potenza (1962) who proved that a traumatic suture of the tendons within their sheath is followed by disintegration of

  13. Magnetic resonance imaging of peripheral neuropathy

    International Nuclear Information System (INIS)

    Nishiura, Yasumasa; Hara, Yuki; Yoshii, Yuichi; Kokubu, Yukihiro; Ochiai, Naoyuki; Niitsu, Mamoru

    2008-01-01

    Development of microscopy coil (MC) in MRI has accomplished high resolution imaging to observe small objects like the minute peripheral nerves and this paper describes authors' experience with the coil of peripheral neuropathy. Subjects are 15 hands of 13 female patients with idiopathic carpal tunnel syndrome (mean age, 64.2 y) and 15 hands of 15 control healthy females (52.5 y). Imaging of extending and bending digits is done with Philips 1.5 T MRI machine using 47 mm MC fixed by a sandbag through modes of T1W, T2W and T2W-fast field echo to evaluate the morphology of flexor tendon and median nerve (and its diameters and area), extension of flexor retinaculum, and area of soft carpal tunnel. It is found the MRI is useful in diagnosis of anterior interosseous neuroparalysis by seeing the morphology above and by detecting fascicles with abnormal brightness and diameter in the median nerve. Future improvement of the MRI technology is promising for progress of the diagnosis and evaluation of the pathogenesis of the disease. (R.T.)

  14. A Rare Case of Simultaneous Acute Bilateral Quadriceps Tendon Rupture and Unilateral Achilles Tendon Rupture

    Directory of Open Access Journals (Sweden)

    Wei Yee Leong

    2013-07-01

    Full Text Available Introduction: There have been multiple reported cases of bilateral quadriceps tendon ruptures (QTR in the literature. These injuries frequently associated with delayed diagnosis, which results in delayed surgical treatment. In very unusual cases, bilateral QTRs can be associated with other simultaneous tendon ruptures. Case Report: We present a rare case of bilateral QTR with a simultaneous Achilles Tendon Rupture involving a 31 years old Caucasian man who is a semi-professional body builder taking anabolic steroids. To date bilateral QTR with additional TA rupture has only been reported once in the literature and to our knowledge this is the first reported case of bilateral QTR and simultaneous TA rupture in a young, fit and healthy individual. Conclusion: The diagnosis of bilateral QTR alone can sometimes be challenging and the possibility of even further tendon injuries should be carefully assessed. A delay in diagnosis could result in delay in treatment and potentially worse outcome for the patient. Keywords: Quadriceps tendon rupture; Achilles tendon rupture; Bilateral.

  15. Achilles tendon healing

    International Nuclear Information System (INIS)

    Dillon, E.H.; Pope, C.F.; Barber, V.; Jokl, P.; Lynch, K.

    1990-01-01

    This paper reports on symptomatic Achilles tendon abnormalities (rupture, tendinitis) evaluated with MR imaging during the healing phase after either surgical or conservative treatment. A total of 21 patients were studied. Fifteen of 21 underwent surgery (13 tendon ruptures) and six were managed conservatively (one rupture). MR studies were obtained before treatment in 11, at 3 months in eight, at 6 months in seven, and at 12 months in 12. The 1.5-T spin-echo and gradient-echo images were correlated with clinical results, planter reflex response times, and calf force measurements. Sequential T2 times were obtained from representative levels in the tendons

  16. The Effect of Phospholipids (Surfactant on Adhesion and Biomechanical Properties of Tendon: A Rat Achilles Tendon Repair Model

    Directory of Open Access Journals (Sweden)

    T. Kursat Dabak

    2015-01-01

    Full Text Available Adhesion of the tendon is a major challenge for the orthopedic surgeon during tendon repair. Manipulation of biological environment is one of the concepts to prevent adhesion. Lots of biochemicals have been studied for this purpose. We aimed to determine the effect of phospholipids on adhesion and biomechanical properties of tendon in an animal tendon repair model. Seventy-two Wistar rats were divided into 4 groups. Achilles tendons of rats were cut and repaired. Phospholipids were applied at two different dosages. Tendon adhesion was determined histopathologically and biomechanical test was performed. At macroscopic evaluation of adhesion, there are statistically significant differences between multiple-dose phospholipid injection group and Control group and also hyaluronic acid group and Control group (p0.008. Ultimate strength was highest at hyaluronic acid injection group and lowest at multiple-dose phospholipid injection group. Single-dose phospholipids (surfactant application may have a beneficial effect on the tendon adhesion. Although multiple applications of phospholipids seem the most effective regime to reduce the tendon adhesion among groups, it deteriorated the biomechanical properties of tendon.

  17. MRI findings of achilles tendon rupture

    International Nuclear Information System (INIS)

    Zhang Xuezhe

    2009-01-01

    Objective: To evaluate the MRI findings of achilles tendon rupture. Methods: The MRI data of 7 patients with achilles tendon rupture were retrospectively analysed. All 7 patients were male with the age ranging from 34 to 71 years. Routine MR scanning was performed in axial and sagittal planes, including T 1 WI, T 2 WI and a fat suppression MRI (SPIR). Results: Among 7 patients, complete achilles tendon rupture was seen in 6 cases, partial achilles tendon rupture 1 case. The site of tendon disruption were 2.6-11.0 cm( mean 5.4 cm) proximal to the insertion in the calcaneus. The MRI findings of a partial or complete rupture of the achilles tendon included enlarged and thickened achilles tendon (7 cases), wavy lax achilles tendon (2 cases), discontinuity of some or all of its fibers and intratendinous regions of increased signal intensity (7 cases). In the cases of complete tendon rupture, the size of the tendinous gap varied from 3.0-8.0 mm, which was filled with blood and appeared as edema of increase signal intensity on T 2 WI and SPIR. In all 7 patients, MR scanning showed medium signal intensity (7 cases) on T 1 WI, or medium signal intensity (1 cases), medium-high signal intensity (3 cases ), high signal intensity (3 cases) on T 2 WI, and medium-high signal intensity (2 cases), high signal intensity (5 cases) on fat suppression MRI. The preachilles fat pad showed obscure in 6 cases of complete achilles tendon rupture. Conclusion: MRI is an excellent method for revealing achilles tendon rupture and confirming the diagnosis. (authors)

  18. Can PRP effectively treat injured tendons?

    Science.gov (United States)

    Wang, James H-C

    2014-01-01

    PRP is widely used to treat tendon and other tissue injuries in orthopaedics and sports medicine; however, the efficacy of PRP treatment on injured tendons is highly controversial. In this commentary, I reason that there are many PRP- and patient-related factors that influence the outcomes of PRP treatment on injured tendons. Therefore, more basic science studies are needed to understand the mechanism of PRP on injured tendons. Finally, I suggest that better understanding of the PRP action mechanism will lead to better use of PRP for the effective treatment of tendon injuries in clinics.

  19. Elbow flexor and extensor muscle weakness in lateral epicondylalgia.

    Science.gov (United States)

    Coombes, Brooke K; Bisset, Leanne; Vicenzino, Bill

    2012-05-01

    To evaluate whether deficits of elbow flexor and extensor muscle strength exist in lateral epicondylalgia (LE) in comparison with a healthy control population. Cross-sectional study. 150 participants with unilateral LE were compared with 54 healthy control participants. Maximal isometric elbow flexion and extension strength were measured bilaterally using a purpose-built standing frame such that gripping was avoided. The authors found significant side differences in elbow extensor (-6.54 N, 95% CI -11.43 to -1.65, p=0.008, standardised mean difference (SMD) -0.45) and flexor muscle strength (-11.26 N, 95% CI -19.59 to -2.94, p=0.009, SMD -0.46) between LE and control groups. Within the LE group, only elbow extensor muscle strength deficits between sides was significant (affected-unaffected: -2.94 N, 95% CI -5.44 to -0.44). Small significant deficits of elbow extensor and flexor muscle strength exist in the affected arm of unilateral LE in comparison with healthy controls. Notably, comparing elbow strength between the affected and unaffected sides in unilateral epicondylalgia is likely to underestimate these deficits. Trial Registration Australian New Zealand Clinical Trials Register ACTRN12609000051246.

  20. Intrinsic contractures of the hand.

    Science.gov (United States)

    Paksima, Nader; Besh, Basil R

    2012-02-01

    Contractures of the intrinsic muscles of the fingers disrupt the delicate and complex balance of intrinsic and extrinsic muscles, which allows the hand to be so versatile and functional. The loss of muscle function primarily affects the interphalangeal joints but also may affect etacarpophalangeal joints. The resulting clinical picture is often termed, intrinsic contracture or intrinsic-plus hand. Disruption of the balance between intrinsic and extrinsic muscles has many causes and may be secondary to changes within the intrinsic musculature or the tendon unit. This article reviews diagnosis, etiology, and treatment algorithms in the management of intrinsic contractures of the fingers. Copyright © 2012 Elsevier Inc. All rights reserved.

  1. An Easy Method for Drainage of Fluid in Cases of Continuous Irrigation of the Hand

    Science.gov (United States)

    Makhijani, Sumeet

    2016-01-01

    Summary: Description of a novel method to perform continuous irrigation for flexor tenosynovitis in a way that is comfortable for the patient and convenient for nursing staff by placing the hand in the suction pouch of a lithotomy style drape attached to wall suction. PMID:28293498

  2. The etiology of idiopathic carpal tunnel syndrome. Evaluation from the viewpoint of magnetic resonance imaging

    International Nuclear Information System (INIS)

    Ikeda, Jun

    2003-01-01

    The etiology of idiopathic carpal tunnel syndrome has not been clarified. A cross sectional area of carpal tunnel, flexor tendons, median nerve, and thickness of transverse carpal ligament were evaluated by MRI. Twenty-six patients who were electrophysiologically diagnosed with idiopathic carpal tunnel syndrome were tested by MRI. All patients were females; the mean age was sixty-four years old. The cross sectional area of carpal tunnel, the median nerve area, the area of the flexor tendons and its synovium in carpal tunnel, and thickness of the transverse carpal ligament were calculated. The following are of a seuere type carpal tunnel syndrome: Mean area of the flexor tendons and its synovium in carpal tunnel, 110.5±25.5 mm 2 (control group; 79.3±13.8 mm 2 ); ratio of flexor tendons and its synovium area to carpal tunnel area, 51.6±8.8% (control; 40.5±2.3%); and thickness of the transverse carpal ligament, 3.3±0.4 mm (control; 2.4±0.4 mm). These mean areas in severe carpal tunnel syndrome were significantly greater than those in mild type (p<0.05 or p<0.01). From the viewpoint of this result, it is possible that tenosynovitis is strongly to the etiology of idiopathic carpal tunnel syndrome. In other words, synovium edema causes chronic high pressure environment in carpal tunnel. Moreover, we classified these MRI findings into the following subgroups: enlargement of cross sectional area of flexor tendon and its synovia (n=8; 25.8%), thickened transverse carpal ligament (n=11; 35.5%), and combined type (n=7; 22.6%). This classification by MRI imaging was related to a clinical course and electro-physiologic severity. The present study suggests that to evaluate the cross sectional, area of an MRI image is useful for diagnosis and cure of idiopathic carpal tunnel syndrome. (author)

  3. Measuring Regional Changes in Damaged Tendon

    Science.gov (United States)

    Frisch, Catherine Kayt Vincent

    Mechanical properties of tendon predict tendon health and function, but measuring these properties in vivo is difficult. An ultrasound-based (US) analysis technique called acoustoelastography (AE) uses load-dependent changes in the reflected US signal to estimate tissue stiffness non-invasively. This thesis explores whether AE can provide information about stiffness alteration resulting from tendon tears both ex vivo and in vivo. An ex vivo ovine infraspinatus tendon model suggests that the relative load transmitted by the different tendon layers transmit different fractions of the load and that ultrasound echo intensity change during cyclic loading decreases, becoming less consistent once the tendon is torn. An in vivo human tibialis anterior tendon model using electrically stimulated twitch contractions investigated the feasibility of measuring the effect in vivo. Four of the five subjects showed the expected change and that the muscle contraction times calculated using the average grayscale echo intensity change compared favorably with the times calculated based on the force data. Finally an AE pilot study with patients who had rotator cuff tendon tears found that controlling the applied load and the US view of the system will be crucial to a successful in vivo study.

  4. Dorsal hand coverage with free serratus fascia flap

    DEFF Research Database (Denmark)

    Fotopoulos, Peter; Holmer, Per; Leicht, Pernille

    2003-01-01

    in the flap, leaving the long thoracic nerve intact on the serratus muscle. Coverage of the flap with split-thickness skin graft is done immediately. The free serratus fascia flap is an ideal flap for dorsal hand coverage when the extensor tendons are exposed, especially because of low donor-site morbidity....

  5. Quadriceps Tendon Rupture and Contralateral Patella Tendon Avulsion Post Primary Bilateral Total Knee Arthroplasty: A Case Report

    Directory of Open Access Journals (Sweden)

    Gaurav Sharma

    2016-07-01

    Full Text Available Background: Extensor mechanism failure secondary to knee replacement could be due to tibial tubercle avulsion, Patellar tendon rupture, patellar fracture or quadriceps tendon rupture. An incidence of Patella tendon rupture of 0.17% and Quadriceps tendon rupture of around 0.1% has been reported after Total knee arthroplasty. These are considered a devastating complication that substantially affects the clinical results and are challenging situations to treat with surgery being the mainstay of the treatment. Case Description: We report here an interesting case of a patellar tendon rupture of one knee and Quadriceps tendon rupture of the contralateral knee following simultaneous bilateral knee replacement in a case of inflammatory arthritis patient. End to end repair for Quadriceps tear and augmentation with Autologous Hamstring tendon graft was done for Patella tendon rupture. OUTCOME: Patient was followed up for a period of 1 year and there was no Extension lag with a flexion of 100 degrees in both the knees. DISCUSSION: The key learning points and important aspects of diagnosing these injuries early and the management techniques are described in this unique case of bilateral extensor mechanism disruption following knee replacements.

  6. Assessment of Myoelectric Controller Performance and Kinematic Behavior of a Novel Soft Synergy-Inspired Robotic Hand for Prosthetic Applications.

    Science.gov (United States)

    Fani, Simone; Bianchi, Matteo; Jain, Sonal; Pimenta Neto, José Simões; Boege, Scott; Grioli, Giorgio; Bicchi, Antonio; Santello, Marco

    2016-01-01

    Myoelectric artificial limbs can significantly advance the state of the art in prosthetics, since they can be used to control mechatronic devices through muscular activity in a way that mimics how the subjects used to activate their muscles before limb loss. However, surveys indicate that dissatisfaction with the functionality of terminal devices underlies the widespread abandonment of prostheses. We believe that one key factor to improve acceptability of prosthetic devices is to attain human likeness of prosthesis movements, a goal which is being pursued by research on social and human-robot interactions. Therefore, to reduce early abandonment of terminal devices, we propose that controllers should be designed so as to ensure effective task accomplishment in a natural fashion. In this work, we have analyzed and compared the performance of three types of myoelectric controller algorithms based on surface electromyography to control an underactuated and multi-degrees of freedom prosthetic hand, the SoftHand Pro. The goal of the present study was to identify the myoelectric algorithm that best mimics the native hand movements. As a preliminary step, we first quantified the repeatability of the SoftHand Pro finger movements and identified the electromyographic recording sites for able-bodied individuals with the highest signal-to-noise ratio from two pairs of muscles, i.e., flexor digitorum superficialis/extensor digitorum communis, and flexor carpi radialis/extensor carpi ulnaris. Able-bodied volunteers were then asked to execute reach-to-grasp movements, while electromyography signals were recorded from flexor digitorum superficialis/extensor digitorum communis as this was identified as the muscle pair characterized by high signal-to-noise ratio and intuitive control. Subsequently, we tested three myoelectric controllers that mapped electromyography signals to position of the SoftHand Pro. We found that a differential electromyography-to-position mapping ensured the

  7. Assessment of Myoelectric Controller Performance and Kinematic Behavior of a Novel Soft Synergy-inspired Robotic Hand for Prosthetic Applications

    Directory of Open Access Journals (Sweden)

    Simone Fani

    2016-10-01

    Full Text Available Myoelectric-artificial limbs can significantly advance the state of the art in prosthetics, since they can be used to control mechatronic devices through muscular activity in a way that mimics how the subjects used to activate their muscles before limb loss. However, surveys indicate that dissatisfaction with the functionality of terminal devices underlies the widespread abandonment of prostheses. We believe that one key factor to improve acceptability of prosthetic devices is to attain human-likeness of prosthesis movements, a goal which is being pursued by research on social and human-robot interactions. Therefore, to reduce early abandonment of terminal devices, we propose that controllers should be designed such as to ensure effective task accomplishment in a natural fashion. In this work, we have analyzed and compared the performance of three types of myoelectric controller algorithms based on surface electromyography to control an under-actuated and multi-degrees of freedom prosthetic hand, the SoftHand Pro. The goal of the present study was to identify the myoelectric algorithm that best mimics the native hand movements. As a preliminary step, we first quantified the repeatability of the SoftHand Pro finger movements and identified the electromyographic recording sites for able-bodied individuals with the highest signal-to-noise ratio from two pairs of muscles, i.e. flexor digitorum superficialis/extensor digitorum communis, and flexor carpi radialis/extensor carpi ulnaris. Able-bodied volunteers were then asked to execute reach-to-grasp movements, while electromyography signals were recorded from flexor digitorum superficialis/extensor digitorum communis as this was identified as the muscle pair characterized by high signal-to-noise ratio and intuitive control. Subsequently, we tested three myoelectric controllers that mapped electromyography signals to position of the SoftHand Pro. We found that a differential electromyography

  8. Role of tissue-engineered artificial tendon in healing of a large Achilles tendon defect model in rabbits.

    Science.gov (United States)

    Moshiri, Ali; Oryan, Ahmad; Meimandi-Parizi, Abdolhamid

    2013-09-01

    Treatment of large Achilles tendon defects is technically demanding. Tissue engineering is an option. We constructed a collagen-based artificial tendon, covered it with a polydioxanon (PDS) sheath, and studied the role of this bioimplant on experimental tendon healing in vivo. A 2-cm tendon gap was created in the left Achilles tendon of rabbits (n = 120). The animals were randomly divided into 3 groups: control (no implant), treated with tridimensional-collagen, and treated with tridimensional-collagen-bidimensional-PDS implants. Each group was divided into 2 subgroups of 60 and 120 days postinjury (DPI). Another 50 pilot animals were used to study the host-implant interaction. Physical activity of the animals was scored and ultrasonographic and bioelectrical characteristics of the injured tendons were investigated weekly. After euthanasia, macro, micro, and nano morphologies and biophysical and biomechanical characteristics of the healing tendons were studied. Treatment improved function of the animals, time dependently. At 60 and 120 DPI, the treated tendons showed significantly higher maximum load, yield, stiffness, stress, and modulus of elasticity compared with controls. The collagen implant induced inflammation and absorbed the migrating fibroblasts in the defect area. By its unique architecture, it aligned the fibroblasts and guided their proliferation and collagen deposition along the stress line of the tendon and resulted in improved collagen density, micro-amp, micro-ohm, water uptake, and delivery of the regenerated tissue. The PDS-sheath covering amplified these characteristics. The implants were gradually absorbed and replaced by a new tendon. Minimum amounts of peritendinous adhesion, muscle atrophy, and fibrosis were observed in the treated groups. Some remnants of the implants were preserved and accepted as a part of the new tendon. The implants were cytocompatible, biocompatible, biodegradable, and effective in tendon healing and regeneration. This

  9. Volume correction in the aging hand: role of dermal fillers

    Directory of Open Access Journals (Sweden)

    Rivkin AZ

    2016-08-01

    Full Text Available Alexander Z Rivkin David Geffen/UCLA School of Medicine Los Angeles, CA, USA Abstract: The hands, just like the face, are highly visible parts of the body. They age at a similar rate and demonstrate comparable changes with time, sun damage, and smoking. Loss of volume in the hands exposes underlying tendons, veins, and bony prominences. Rejuvenation of the hands with dermal fillers is a procedure with high patient satisfaction and relatively low risk for complications. This study will review relevant anatomy, injection technique, clinical safety, and efficacy of dermal filler volumization of the aging hand. Keywords: dermal fillers, hands, volumization, hyaluronic acid, calcium hydroxylapatite

  10. Pressure pain and isometric strength of neck flexors are related in chronic tension-type headache.

    Science.gov (United States)

    Castien, Rene; Blankenstein, Annette; De Hertogh, Willem

    2015-01-01

    In patients with chronic tension-type headache (CTTH) changes in pressure pain in the cervical region are associated with peripheral or central sensitization. It is hypothesized that an increase of isometric strength of neck flexors would lead to a decrease of pressure pain in CTTH, as an expression of reduced peripheral or central sensitization In this study we aimed to analyze the correlation between change in isometric strength of the neck flexors and change in pressure pain scores (PPS) in patients with CTTH. Comparative analysis of data from previous study. Primary healthcare center. Data from 145 patients with CTTH who underwent a manual therapy program including isometric strength training of the neck flexors were analyzed at 8 and 26 weeks post-treatment. PPS were measured as a total of pain scores on a numeric rating scale (score 0 to 10) on application of a pressure stimulus of 3kg/cm at 8 cervical- and suboccipital muscles. Isometric strength of the neck flexors was measured in seconds. Correlations were computed between changes in PPS and isometric neck flexor strength. Isometric strength of neck flexors scored significantly different compared to baseline measurement (mean 30.0 seconds, sd:25.2), and increased with a mean difference of 17.33 seconds (95%CI: 20.61 to 14.05) at 8 weeks and 19.18 seconds (95%CI: 23.48 to 14.87) at 26 weeks. Similarly, compared to PPS baseline measurement (31.6 points, sd:18.6), mean difference in PPS was significantly decreased at 8 and 26 weeks: -11.3 points (95%CI: -8.77 to -13.83) and -11.15 points (95%CI: -8.31 to -13.99). There is a negative correlation between changes in PPS and changes in isometric strength of neck flexors which is weak at 8 weeks (r = -0.243, P = 0.004) and moderate at 26 weeks (r = -0.318, P isometric strength of neck flexors in patients with CTTH in short- and long-term.

  11. Are Ultrasonographic Measures of Cervical Flexor Muscles Correlated With Flexion Endurance in Chronic Neck Pain and Asymptomatic Participants?

    Science.gov (United States)

    Ghamkhar, Leila; Kahlaee, Amir Hossein

    2017-12-01

    This study compared the relationship between some clinical factors and the size of neck flexors in participants with or without chronic neck pain. In this case-control study, the correlation between flexor endurance capacity as well as thickness, cross-section area, and shape ratio of longus colli/capitis and sternocleidomastoid muscles were examined in 30 patients with chronic neck pain and 30 asymptomatic participants. The patients showed lower flexor endurance (P = 0.02), smaller thickness (P = 0.03), and cross-section area (P pain. In the control group, flexor endurance was negatively correlated with longus colli shape ratio (r = -0.45, P = 0.01) but positively correlated with longus capitis thickness (r = 0.45, P = 0.01) and cross-section area (r = 0.38, P = 0.03). Neck disability and pain intensity indices were not significantly correlated with either flexor muscles endurance or size. The ultrasonographic measures of the deep neck flexor muscles and the flexor endurance test, being associated with each other, could successfully differentiate patients with chronic neck pain from asymptomatic participants. However, the endurance test scores were not correlated with self-reported disability or pain intensity indices.

  12. Selective recruitment of single motor units in human flexor digitorum superficialis muscle during flexion of individual fingers.

    Science.gov (United States)

    Butler, T J; Kilbreath, S L; Gorman, R B; Gandevia, S C

    2005-08-15

    Flexor digitorum superficialis (FDS) is an extrinsic multi-tendoned muscle which flexes the proximal interphalangeal joints of the four fingers. It comprises four digital components, each with a tendon that inserts onto its corresponding finger. To determine the degree to which these digital components can be selectively recruited by volition, we recorded the activity of a single motor unit in one component via an intramuscular electrode while the subject isometrically flexed each of the remaining fingers, one at a time. The finger on which the unit principally acted was defined as the 'test finger' and that which flexed isometrically was the 'active' finger. Activity in 79 units was recorded. Isometric finger flexion forces of 50% maximum voluntary contraction (MVC) activated less than 50% of single units in components of FDS acting on fingers that were not voluntarily flexed. With two exceptions, the median recruitment threshold for all active-test finger combinations involving the index, middle, ring and little finger test units was between 49 and 60% MVC (60% MVC being the value assigned to those not recruited). The exceptions were flexion of the little finger while recording from ring finger units (median: 40% MVC), and vice versa (median: 2% MVC). For all active-test finger combinations, only 35/181 units were activated when the active finger flexed at less than 20% MVC, and the fingers were adjacent for 28 of these. Functionally, to recruit FDS units during grasping and lifting, relatively heavy objects were required, although systematic variation occurred with the width of the object. In conclusion, FDS components can be selectively activated by volition and this may be especially important for grasping at high forces with one or more fingers.

  13. Case report: accessory head of the deep forearm flexors

    Science.gov (United States)

    JONES, M.; ABRAHAMS, P. H.; SAÑUDO, J. R.

    1997-01-01

    In 1813 Gantzer described 2 accessory muscles in the human forearm which bear his name (Wood, 1868; Macalister, 1875) and these have subsequently been reported with variable attachments (Wood, 1868; Macalister, 1875; Turner, 1879; Schäfer & Thane, 1894; Le Double, 1897; Dykes & Anson, 1944; Mangini, 1960; Malhotra et al. 1982; Kida, 1988; Tountas & Bergman, 1993). The accessory heads of the deep flexors of the forearm (Gantzer's muscles) have been described as 2 different small bellies which insert either into FPL or FDP. There are no previous reports which have mentioned the existence of an accessory muscle which inserts into both of the 2 deep flexors of the forearm as in the case presented here. PMID:9306208

  14. Effects of hand-training in persons with myotonic dystrophy type 1--a randomised controlled cross-over pilot study.

    Science.gov (United States)

    Aldehag, Anna; Jonsson, Hans; Lindblad, Jan; Kottorp, Anders; Ansved, Tor; Kierkegaard, Marie

    2013-10-01

    To investigate the effects of a hand-training programme on grip, pinch and wrist force, manual dexterity and activities of daily living, in adults with myotonic dystrophy type 1 (DM1). In this randomised controlled trial with a crossover design, 35 adults with DM1 were, after stratification for grip force, assigned by lot to two groups. Group A started with 12 weeks of hand training, while group B had no intervention. After a wash-out period of 12 weeks, where none received training, the order was reversed. The Grippit® was used as primary outcome measure and the hand-held Microfet2™ myometer, the Purdue Pegboard, the Canadian Occupational Performance Measure (COPM) and the Assessment of Motor and Process Skills (AMPS) were secondary outcome measures. Assessments were performed before and after training and control periods, i.e. four times altogether. Ten persons dropped out and 13 had acceptable adherence. Intention-to-treat analyses revealed significant intervention effects for isometric wrist flexor force (p = 0.048), and for COPM performance (p = 0.047) and satisfaction (p = 0.027). On an individual level, improvements were in general showed after a training period. The hand-training programme had positive effects on wrist flexor force and self-perception of occupational performance, and of satisfaction with performance. No evident detrimental effects were shown. Myotonic dystrophy type 1 (DM1) is a slowly progressive neuromuscular disease characterised by myotonia and muscle weakness and wasting. People with DM1 are often concerned about their ability to carry out ADL and to participate in, e.g. work, sports and hobbies when they gradually become weaker. This pilot study showed that a hand-training programme improved wrist flexor force and self-perception and satisfaction of occupational performance. Resistance training of hand muscles with a silicon-based putty can be a therapy option for people with DM1 in clinical practise.

  15. The roentgenographic findings of achilles tendon rupture

    Energy Technology Data Exchange (ETDEWEB)

    Seouk, Kang Hyo; Keun, Rho Yong [Shilla General Hospital, Seoul (Korea, Republic of)

    1999-03-01

    To evaluate the diagnostic value of a lateral view of the ankles in Achilles tendon rupture. We performed a retrospective analysis of the roentgenographic findings of 15 patients with surgically proven Achilles tendon rupture. Four groups of 15 patients(normal, ankle sprain, medial lateral malleolar fracture, and calcaneal fracture) were analysed as reference groups. Plain radiographs were reviewed with regard to Kager's triangle, Arner's sign, Toygar's angle, ill defined radiolucent shadow through the Achilles tendon, sharpness of the anterior margin of Achilles tendon, and meniscoid smooth margin of the posterior skin surface of the ankle. Kager's triangle was deformed and disappeared after rupture of the Achilles tendon in nine patients(60%) with operative verification of the rupture, six patients(40%) had a positive Arner's sign, while none had a diminished Toygars angle. In 13 patients(87%) with a ruptured Achilles tendon, the thickness of this was nonuniform compared with the reference group. The anterior margin of the Achilles tendon became serrated and indistinct in 14 patients(93%) in whom this was ruptured. An abnormal ill defined radiolucent shadow through the Achilles tendon was noted in nine patient(60%), and nonparallelism between the anterior margin of the Achilles tendon and posterior skin surface of the ankle was detected in 11 patients(73%). The posterior skin surface of the ankle had a nodular surface margin in 13 patients(87%). A deformed Kager's triangle and Achilles tendon, and an abnormal ill defined radiolucent shadow through the Achilles tendon in a lateral view of the ankles are important findings for the diagnesis of in diagnosing achilles tendon rupture.

  16. The roentgenographic findings of achilles tendon rupture

    International Nuclear Information System (INIS)

    Seouk, Kang Hyo; Keun, Rho Yong

    1999-01-01

    To evaluate the diagnostic value of a lateral view of the ankles in Achilles tendon rupture. We performed a retrospective analysis of the roentgenographic findings of 15 patients with surgically proven Achilles tendon rupture. Four groups of 15 patients(normal, ankle sprain, medial lateral malleolar fracture, and calcaneal fracture) were analysed as reference groups. Plain radiographs were reviewed with regard to Kager's triangle, Arner's sign, Toygar's angle, ill defined radiolucent shadow through the Achilles tendon, sharpness of the anterior margin of Achilles tendon, and meniscoid smooth margin of the posterior skin surface of the ankle. Kager's triangle was deformed and disappeared after rupture of the Achilles tendon in nine patients(60%) with operative verification of the rupture, six patients(40%) had a positive Arner's sign, while none had a diminished Toygars angle. In 13 patients(87%) with a ruptured Achilles tendon, the thickness of this was nonuniform compared with the reference group. The anterior margin of the Achilles tendon became serrated and indistinct in 14 patients(93%) in whom this was ruptured. An abnormal ill defined radiolucent shadow through the Achilles tendon was noted in nine patient(60%), and nonparallelism between the anterior margin of the Achilles tendon and posterior skin surface of the ankle was detected in 11 patients(73%). The posterior skin surface of the ankle had a nodular surface margin in 13 patients(87%). A deformed Kager's triangle and Achilles tendon, and an abnormal ill defined radiolucent shadow through the Achilles tendon in a lateral view of the ankles are important findings for the diagnesis of in diagnosing achilles tendon rupture

  17. The Relative Contribution to Small Finger Abduction of the Ulnar Versus Radial Slip of the EDM: Implications for Tendon Transfers.

    Science.gov (United States)

    Akinleye, Sheriff D; Culbertson, Maya Deza; Cappelleti, Giacomo; Garofolo, Garret; Choueka, Jack

    2017-09-01

    The extensor digiti minimi (EDM) tendon is commonly divided into a radial slip (EDM-R) and an ulnar slip (EDM-U). To our knowledge, the degree to which each EDM slip concomitantly abducts the small finger with active extension has not been formally tested. This study sought to characterize the comparative contributions of finger abduction inherent to each slip of the EDM to observe the sequelae of active small finger extension following transfer of the contralateral slip. Eighteen fresh-frozen cadaveric hands were used in this study. Starting with the hand in resting position, a controlled traction of 10 N was applied to each slip of the EDM tendon. The range of small finger abduction with respect to the fixed ring finger was recorded utilizing infrared reflective markers tracked through the range of motion using a digital video camera. The mean abduction of the small finger when the radial slip of the EDM tendon was tested was 13.33° (95% confidence interval [CI]: 10.10°-16.55°), which was significantly different ( P ≤ .001) than small finger abduction produced by the ulnar slip of the EDM, with a mean of 23.72° (95% CI: 19.40°-28.04°). Given the fact that the ulnar slip of the EDM tendon is shown to be the major contributor of aberrant abduction with active small finger extension, as traction on this slip produces almost twice as much abduction as the radial slip, the EDM-U is the ideal donor graft with respect to tendon transfers of the EDM.

  18. Tendon Force Transmission at the Nanoscale

    DEFF Research Database (Denmark)

    Svensson, René

    2013-01-01

    of connective tissue function that are poorly understood. One such aspect is the microscopic mechanisms of force transmission through tendons over macroscopic distances. Force transmission is at the heart of tendon function, but the large range of scales in the hierarchical structure of tendons has made...... it difficult to tackle. The tendon hierarchy ranges from molecules (2 nm) over fibrils (200 nm), fibers (2 μm) and fascicles (200 μm) to tendons (10 mm), and to derive the mechanisms of force transmission it is necessary to know the mechanical behavior at each hierarchical level. The aim of the present work...... was to elucidate the mechanisms of force transmission in tendons primarily by investigating the mechanical behavior at the hierarchical level of collagen fibrils. To do so we have developed an atomic force microscopy (AFM) method for tensile testing of native collagen fibrils. The thesis contains five papers...

  19. Recurrent Mycobacterium marinum tenosynovitis of the wrist mimicking extraarticular synovial chondromatosis on MR images

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Edward Y.; Rubin, David A. [Department of Radiology, Mallinckrodt Institute of Radiology, St. Louis, MO (United States); Brown, David M. [The Orthopedic Center of St. Louis, St. Louis, MO (United States)

    2004-07-01

    Tenosynovitis caused by atypical mycobacterial infections may produce rice bodies within affected tendon sheaths. We report a case of recurrent M. marinum infection involving the flexor tendons within the carpal tunnel in which the rice bodies were mistaken for synovial chondromatosis on MR images. (orig.)

  20. Recurrent Mycobacterium marinum tenosynovitis of the wrist mimicking extraarticular synovial chondromatosis on MR images

    International Nuclear Information System (INIS)

    Lee, Edward Y.; Rubin, David A.; Brown, David M.

    2004-01-01

    Tenosynovitis caused by atypical mycobacterial infections may produce rice bodies within affected tendon sheaths. We report a case of recurrent M. marinum infection involving the flexor tendons within the carpal tunnel in which the rice bodies were mistaken for synovial chondromatosis on MR images. (orig.)

  1. Unusual case of cleft hand

    Directory of Open Access Journals (Sweden)

    Sahasrabudhe Parag

    2007-01-01

    Full Text Available We present a case of a six-year-old male child with cleft hand deformity involving the dominant right hand. It was a rare case of atypical cleft hand with no missing tissue but cleft extending to metacarpal level and associated hypoplasia of thumb and index finger. As per Manske′s classification of cleft hand our patient belongs to the Class III variety. There was associated malposition of the index finger with absence of first web space and syndactly of thumb and index finger at the metacarpal level. A modified Snow-Littler procedure was planned. The surgical plan involved closure of cleft, release of thumb and index finger syndactly and reconstruction of the first web space. The functional outcome was good considering hypoplasia of the index finger and thumb. Depending upon the function of the thumb tendon transfers can be planned to augment thumb function at a later date along with correction of rotational deformities of the index and middle finger.

  2. Biology and augmentation of tendon-bone insertion repair

    OpenAIRE

    Lui, PPY; Zhang, P; Chan, KM; Qin, L

    2010-01-01

    Abstract Surgical reattachment of tendon and bone such as in rotator cuff repair, patellar-patella tendon repair and anterior cruciate ligament (ACL) reconstruction often fails due to the failure of regeneration of the specialized tissue ("enthesis") which connects tendon to bone. Tendon-to-bone healing taking place between inhomogenous tissues is a slow process compared to healing within homogenous tissue, such as tendon to tendon or bone to bone healing. Therefore special attention must be ...

  3. Effect of single intralesional treatment of surgically induced equine superficial digital flexor tendon core lesions with adipose-derived mesenchymal stromal cells : a controlled experimental trial

    NARCIS (Netherlands)

    Geburek, Florian; Roggel, Florian; van Schie, Hans T M; Beineke, Andreas; Estrada, Roberto; Weber, Kathrin; Hellige, Maren; Rohn, Karl; Jagodzinski, Michael; Welke, Bastian; Hurschler, Christof; Conrad, Sabine; Skutella, Thomas; van de Lest, Chris; van Weeren, René; Stadler, Peter M

    2017-01-01

    BACKGROUND: Adipose tissue is a promising source of mesenchymal stromal cells (MSCs) for the treatment of tendon disease. The goal of this study was to assess the effect of a single intralesional implantation of adipose tissue-derived mesenchymal stromal cells (AT-MSCs) on artificial lesions in

  4. Bone marrow-derived mesenchymal stem cells influence early tendon-healing in a rabbit achilles tendon model.

    Science.gov (United States)

    Chong, Alphonsus K S; Ang, Abel D; Goh, James C H; Hui, James H P; Lim, Aymeric Y T; Lee, Eng Hin; Lim, Beng Hai

    2007-01-01

    A repaired tendon needs to be protected for weeks until it has accrued enough strength to handle physiological loads. Tissue-engineering techniques have shown promise in the treatment of tendon and ligament defects. The present study tested the hypothesis that bone marrow-derived mesenchymal stem cells can accelerate tendon-healing after primary repair of a tendon injury in a rabbit model. Fifty-seven New Zealand White rabbits were used as the experimental animals, and seven others were used as the source of bone marrow-derived mesenchymal stem cells. The injury model was a sharp complete transection through the midsubstance of the Achilles tendon. The transected tendon was immediately repaired with use of a modified Kessler suture and a running epitendinous suture. Both limbs were used, and each side was randomized to receive either bone marrow-derived mesenchymal stem cells in a fibrin carrier or fibrin carrier alone (control). Postoperatively, the rabbits were not immobilized. Specimens were harvested at one, three, six, and twelve weeks for analysis, which included evaluation of gross morphology (sixty-two specimens), cell tracing (twelve specimens), histological assessment (forty specimens), immunohistochemistry studies (thirty specimens), morphometric analysis (forty specimens), and mechanical testing (sixty-two specimens). There were no differences between the two groups with regard to the gross morphology of the tendons. The fibrin had degraded by three weeks. Cell tracing showed that labeled bone marrow-derived mesenchymal stem cells remained viable and present in the intratendinous region for at least six weeks, becoming more diffuse at later time-periods. At three weeks, collagen fibers appeared more organized and there were better morphometric nuclear parameters in the treatment group (p tendon repair can improve histological and biomechanical parameters in the early stages of tendon-healing.

  5. Arthrography of the biceps tendon

    International Nuclear Information System (INIS)

    Ahovuo, J.; Linden, H.; Hovi, I.; Paavolainen, P.; Bjoerkenheim, J.M.

    1988-01-01

    The purpose of this study was to analyse the factors having an influence on the arthrographic imaging of the biceps tendon. The study comprised 174 patients suffering from chronic shoulder pain. They underwent conventional shoulder arthrography with sodium meglumine metrizoate or metrizamide as a contrast medium. In the patients with a full-thickness tear of the rotator cuff, the biceps tendon sheath failed to fill with contrast medium more often than in those with an intact tendinous cuff. Metrizamide filled the biceps tendon sheath more readily than sodium meglumine metrizoate in patients with a full-thickness tear of the ortator cuff. The volume of the contrast medium injected had no influence on the imaging of the biceps tendon. (orig.)

  6. Didatic approach of ultrasonographic examination for evaluation of the carpal joint in horses

    Directory of Open Access Journals (Sweden)

    Maria Cristina Ferrarini Nunes Soares Hage

    2017-11-01

    Full Text Available ABSTRACT: The carpus is a complex articulation, which is often involved in injuries in equine athletes. The objective of this study was to suggest a didactic approach for ultrasonography training for the examination of the carpal joint in horses. Ultrasonograhy examination was performed in a healthy 14-year-old horse. The images were compared with those of a dissected anatomic specimen of the carpal region of a senior horse and with those reported in the literature. Identifiable structures were as follows: (dorsal tendon of the muscle extensor carpi radialis, tendon of the muscle extensor carpi obliquus, tendon of the muscle commom digital extensor, dorsal synovial outpouchings, joint capsule and fat cushion, (lateral tendon of the muscle lateral digital extensor, lateral collateral ligament (deep and superficial components, (medial medial collateral ligament (deep and superficial components and (palmar palmar intercarpal ligament, carpal sheath, carpal tunnel, superficial digital flexor tendon, proximal origin of the deep digital flexor tendon, and palmar carpal ligament. Prior knowledge of the anatomy in combination with the study of anatomical specimens is essential for recognizing musculoskeletal structures during ultrasound examination, contributing to the training and learning processes.

  7. Severity of upper-limb panga injuries and infection rates associated ...

    African Journals Online (AJOL)

    The injuries sustained included 32 flexor tendon injuries, 14 extensor tendon injuries, 9 fractures and 21 peripheral nerve injuries. Results. Of the patients, 17 underwent early primary repair (within 24 h), 19 delayed primary repair, and 13 delayed repair following primary washout. Wounds were assessed postoperatively ...

  8. Grasp Assist Device with Shared Tendon Actuator Assembly

    Science.gov (United States)

    Ihrke, Chris A. (Inventor); Bergelin, Bryan J. (Inventor); Bridgwater, Lyndon (Inventor)

    2015-01-01

    A grasp assist device includes a glove with first and second tendon-driven fingers, a tendon, and a sleeve with a shared tendon actuator assembly. Tendon ends are connected to the respective first and second fingers. The actuator assembly includes a drive assembly having a drive axis and a tendon hook. The tendon hook, which defines an arcuate surface slot, is linearly translatable along the drive axis via the drive assembly, e.g., a servo motor thereof. The flexible tendon is routed through the surface slot such that the surface slot divides the flexible tendon into two portions each terminating in a respective one of the first and second ends. The drive assembly may include a ball screw and nut. An end cap of the actuator assembly may define two channels through which the respective tendon portions pass. The servo motor may be positioned off-axis with respect to the drive axis.

  9. Biology and augmentation of tendon-bone insertion repair

    Directory of Open Access Journals (Sweden)

    Lui PPY

    2010-08-01

    Full Text Available Abstract Surgical reattachment of tendon and bone such as in rotator cuff repair, patellar-patella tendon repair and anterior cruciate ligament (ACL reconstruction often fails due to the failure of regeneration of the specialized tissue ("enthesis" which connects tendon to bone. Tendon-to-bone healing taking place between inhomogenous tissues is a slow process compared to healing within homogenous tissue, such as tendon to tendon or bone to bone healing. Therefore special attention must be paid to augment tendon to bone insertion (TBI healing. Apart from surgical fixation, biological and biophysical interventions have been studied aiming at regeneration of TBI healing complex, especially the regeneration of interpositioned fibrocartilage and new bone at the healing junction. This paper described the biology and the factors influencing TBI healing using patella-patellar tendon (PPT healing and tendon graft to bone tunnel healing in ACL reconstruction as examples. Recent development in the improvement of TBI healing and directions for future studies were also reviewed and discussed.

  10. The Effect of Sodium Hyaluronate on Ligamentation and Biomechanical Property of Tendon in Repair of Achilles Tendon Defect with Polyethylene Terephthalate Artificial Ligament: A Rabbit Tendon Repair Model.

    Science.gov (United States)

    Li, Shengkun; Ma, Kui; Li, Hong; Jiang, Jia; Chen, Shiyi

    2016-01-01

    The Achilles tendon is the most common ruptured tendon of human body. Reconstruction with polyethylene terephthalate (PET) artificial ligament is recommended in some serious cases. Sodium hyaluronate (HA) is beneficial for the healing of tendon injuries. We aimed to determine the effect of sodium hyaluronate in repair of Achilles tendon defect with PET artificial ligament in an animal tendon repair model. Sixteen New Zealand White rabbits were divided into two groups. Eight rabbits repaired with PET were assigned to PET group; the other eight rabbits repaired with PET along with injection of HE were assigned to HA-PET group. All rabbits were sacrificed at 4 and 8 weeks postoperatively for biomechanical and histological examination. The HA-PET group revealed higher biomechanical property compared with the PET group. Histologically, more collagen tissues grew into the HA-PET group compared with PET group. In conclusion, application of sodium hyaluronate can improve the healing of Achilles tendon reconstruction with polyethylene terephthalate artificial ligament.

  11. The Effect of Sodium Hyaluronate on Ligamentation and Biomechanical Property of Tendon in Repair of Achilles Tendon Defect with Polyethylene Terephthalate Artificial Ligament: A Rabbit Tendon Repair Model

    Directory of Open Access Journals (Sweden)

    Shengkun Li

    2016-01-01

    Full Text Available The Achilles tendon is the most common ruptured tendon of human body. Reconstruction with polyethylene terephthalate (PET artificial ligament is recommended in some serious cases. Sodium hyaluronate (HA is beneficial for the healing of tendon injuries. We aimed to determine the effect of sodium hyaluronate in repair of Achilles tendon defect with PET artificial ligament in an animal tendon repair model. Sixteen New Zealand White rabbits were divided into two groups. Eight rabbits repaired with PET were assigned to PET group; the other eight rabbits repaired with PET along with injection of HE were assigned to HA-PET group. All rabbits were sacrificed at 4 and 8 weeks postoperatively for biomechanical and histological examination. The HA-PET group revealed higher biomechanical property compared with the PET group. Histologically, more collagen tissues grew into the HA-PET group compared with PET group. In conclusion, application of sodium hyaluronate can improve the healing of Achilles tendon reconstruction with polyethylene terephthalate artificial ligament.

  12. Thompson Test in Achilles Tendon Rupture

    Directory of Open Access Journals (Sweden)

    Spencer Albertson

    2016-07-01

    Full Text Available HPI: A 26-year old male presented to the emergency department after experiencing the acute onset of left ankle pain while playing basketball. Upon jumping, he felt a “pop” in his left posterior ankle, followed by pain and difficulty ambulating. His exam was notable for a defect at the left Achilles tendon on palpation. The practitioner performed a Thompson test, which was positive (abnormal on the left. Significant Findings: The left Achilles tendon had a defect on palpation, while the right Achilles tendon was intact. When squeezing the right (unaffected calf, the ankle spontaneously plantar flexed, indicating a negative (normal Thompson test. Upon squeeze of the left (affected calf, the ankle did not plantar flex, signifying a positive (abnormal Thompson test. The diagnosis of left Achilles tendon rupture was confirmed intraoperatively one week later. Discussion: The Achilles tendon (also: calcaneal tendon or heel cord is derived from the medial and lateral heads of the gastrocnemius muscle, as well as the soleus muscle. Rupture of the Achilles tendon most commonly occurs in the distal tendon, approximately 2-6 cm from its attachment to the calcaneal tuberosity, in an area of hypovascularity known as the “watershed” or “critical” zone.1-3 The Thompson test (also: Simmonds-Thompson test, described by Simmonds in 1957 and Thompson in 1962, is done while the patient is in the prone position, with feet hanging over the end of a table/gurney, or with the patient kneeling on a stool or chair.4-5 Squeezing the calf of an unaffected limb will cause the ankle to plantar flex, but squeezing the calf of a limb with an Achilles tendon rupture will cause no motion. The sensitivity of the Thompson’s test for the diagnosis of a complete Achilles tendon rupture is 96-100% and the specificity is 93-100%, but data is limited.6-8

  13. Stenosing tenosynovitis

    OpenAIRE

    Vuillemin, V.; Guerini, H.; Bard, H.; Morvan, G.

    2012-01-01

    Tenosynovitis refers to an inflammatory condition involving the synovial sheath of a tendon. Stenosing tenosynovitis is a peculiar entity caused by multiple factors, including local anatomy, mechanical factors, and hormonal factors. The main forms include de Quervain tendinopathy; trigger finger (stenosing tenosynovitis involving the flexor digitorum tendons); stenosing tenosynovitis of the extensor carpi ulnaris, extensor carpi radialis, or extensor comunis tendons; stenosing tenosynovitis o...

  14. Biomechanical and histologic comparison of Achilles tendon ruptures reinforced with intratendinous and peritendinous plantaris tendon grafts in rabbits: an experimental study.

    Science.gov (United States)

    Ilhami, Kuru; Gokhan, Maralcan; Ulukan, Inan; Eray, Bozan M; Levent, Altinel; Ciğdem, Tokyol

    2004-11-01

    We hypothesized that the closer the reinforcing graft was to the repair zone, the more strength the healed tendon would achieved. Therefore, we compared the ruptured rabbit Achilles tendons reinforced with intratendinous and peritendinous plantaris grafts. The experimental study was performed on Achilles tendons of 20 rabbits. First, they were divided into two groups: group I (n=10) underwent intratendinous graft and end-to-end tenorraphy, and group P (n=10) were repaired end-to-end and then reinforced with a peritendinous plantaris graft. An above-knee cast was applied during 6 weeks postoperatively. The two groups were compared to each other biomechanically and histologically. Seven randomly selected rabbits from each group were used for biomechanical evaluation. The remaining six rabbits (three from each group) were used for histologic comparison. Non-operated sides (n=20) served as the control group. The mean maximum load at rupture of the repaired and control groups was 159.9+/-31 N, 83+/-7.5 N, and 207.5+/-35 N for group I, group P, and the control group, respectively. Values between groups were significantly different considering maximum load and absorbed energy to rupture. There was no significant difference between groups I and P in respect to strain. Control group tendons (groups I-C and P-C) had significantly more lengthening capability than operated tendons. Macroscopically, group I tendons were thicker and stiffer than group P tendons. Histologically, differences between the group I and group P specimens revealed that the healing process was faster in tendons augmented intratendinously. In reinforcing Achilles tendon repair, the site of the tendon graft affected the result. When the graft was used intratendinously, the healed tendon was more similar biomechanically to normal tendon and had more graft-tendon orientation histologically than the tendon augmented peritendinously.

  15. Simultaneous bilateral patellar tendon rupture ?

    OpenAIRE

    Moura, Diogo Lino; Marques, Jos? Pedro; Lucas, Francisco Manuel; Fonseca, Fernando Pereira

    2016-01-01

    Bilateral patellar tendon rupture is a rare entity, often associated with systemic diseases and patellar tendinopathy. The authors report a rare case of a 34-year-old man with simultaneous bilateral rupture of the patellar tendon caused by minor trauma. The patient is a retired basketball player with no past complaints of chronic knee pain and a history of steroid use. Surgical management consisted in primary end-to-end tendon repair protected temporarily with cerclage wiring, followed by a s...

  16. TGIF1 Gene Silencing in Tendon-Derived Stem Cells Improves the Tendon-to-Bone Insertion Site Regeneration

    Directory of Open Access Journals (Sweden)

    Liyang Chen

    2015-11-01

    Full Text Available Background/Aims: The slow healing process of tendon-to-bone junctions can be accelerated via implanted tendon-derived stem cells (TDSCs with silenced transforming growth interacting factor 1 (TGIF1 gene. Tendon-to-bone insertion site is the special form of connective tissues derivatives of common connective progenitors, where TGF-β plays bidirectional effects (chondrogenic or fibrogenic through different signaling pathways at different stages. A recent study revealed that TGF-β directly induces the chondrogenic gene Sox9. However, TGIF1 represses the expression of the cartilage master Sox9 gene and changes its expression rate against the fibrogenesis gene Scleraxis (Scx. Methods: TGIF1 siRNA was transduced or TGIF1 was over-expressed in tendon-derived stem cells. Following suprapinatus tendon repair, rats were either treated with transduced TDSCs or nontransduced TDSCs. Histologic examination and Western blot were performed in both groups. Results: In this study, the silencing of TGIF1 significantly upregulated the chondrogenic genes and markers. Similarly, TGIF1 inhibited TDSC differentiation into cartilage via interactions with TGF-β-activated Smad2 and suppressed the phosphorylation of Smad2. The area of fibrocartilage at the tendon-bone interface was significantly increased in the TGIF1 (- group compared with the control and TGIF1-overexpressing groups in the early stages of the animal model. The interface between the tendon and bone showed a increase of new bone and fibrocartilage in the TGIF1 (- group at 4 weeks. Fibrovascular scar tissue was observed in the TGIF1-overexpressing group and the fibrin glue only group. Low levels of fibrocartilage and fibrovascular scar tissue were found in the TDSCs group. Conclusion: Collectively, this study shows that the tendon-derived stem cell modified with TGIF1 gene silencing has promising effects on tendon-to-bone healing which can be further explored as a therapeutic tool in regenerative medicine.

  17. Comparisons of eccentric knee flexor strength and asymmetries across elite, sub-elite and school level cricket players

    Directory of Open Access Journals (Sweden)

    Wade J. Chalker

    2016-02-01

    Full Text Available Background. There has been a continual increase in injury rates in cricket, with hamstring strain injuries (HSIs being the most prominent. Eccentric knee flexor weakness and bilateral asymmetries are major modifiable risk factors for future HSIs. However, there is a lack of data relating to eccentric hamstring strength in cricket at any skill level. The objective of this study was to compare eccentric knee flexor strength and bilateral asymmetries in elite, sub-elite and school level cricket players; and to determine if playing position and limb role influenced these eccentric knee flexor strength indices. Methods. Seventy four male cricket players of three distinct skill levels performed three repetitions of the Nordic hamstring exercise on the experimental device. Strength was assessed as the absolute and relative mean peak force output for both limbs, with bilateral asymmetries. Differences in mean peak force outputs between skill level and playing positions were measured. Results. There were no significant differences between elite, sub-elite and school level athletes for mean peak force and bilateral asymmetries of the knee flexors. There were no significant differences observed between bowler’s and batter’s mean peak force and bilateral asymmetries. There were no significant differences between front and back limb mean peak force outputs. Discussion. Skill level, playing position and limb role appeared to have no significant effect on eccentric knee flexor strength and bilateral asymmetries. Future research should seek to determine whether eccentric knee flexor strength thresholds are predictive of HSIs in cricket and if specific eccentric knee flexor strengthening can reduce these injuries.

  18. FRP tendon anchorage in post-tensioned concrete structures

    DEFF Research Database (Denmark)

    Schmidt, Jacob Wittrup; Täljsten, Björn; Bennitz, Anders

    2008-01-01

    effective Young´s modulus and the high stress capacity in the linear elastic range of the material. The use of external tendons increases the requirements on the anchorage systems. This is in particular important when using un-bonded tendon systems, where the anchorage and deviators are the only force...... transfer points. The demand for high capacity anchorage tendons is fulfilled for steel tendons, but no competitive mechanical anchor has yet been developed for FRP tendon. A new small, reliable and more user friendly anchor has to be developed, before FRP tendons can be utilized with all of its capacity...

  19. MR Imaging and US of the Wrist Tendons.

    Science.gov (United States)

    Plotkin, Benjamin; Sampath, Srihari C; Sampath, Srinath C; Motamedi, Kambiz

    2016-10-01

    The tendons of the wrist are commonly symptomatic. They can be injured, infected, or inflamed. Magnetic resonance imaging and ultrasonography are useful tools for evaluating the wrist. Pathologic conditions of the wrist tendons include de Quervain tenosynovitis, extensor carpi ulnaris tendinopathy, rheumatoid tenosynovitis, infectious synovitis, tendon tears, hydroxyapatite deposition disease, intersection syndrome, tenosynovial giant cell tumor, and fibroma of the tendon sheath. In this article, we review the normal appearance of the wrist tendons, discuss relevant anatomy, and give an overview of common pathologic conditions affecting the wrist tendons. Online supplemental material is available for this article. © RSNA, 2016.

  20. Repair of Achilles tendon defect with autologous ASCs engineered tendon in a rabbit model.

    Science.gov (United States)

    Deng, Dan; Wang, Wenbo; Wang, Bin; Zhang, Peihua; Zhou, Guangdong; Zhang, Wen Jie; Cao, Yilin; Liu, Wei

    2014-10-01

    Adipose derived stem cells (ASCs) are an important cell source for tissue regeneration and have been demonstrated the potential of tenogenic differentiation in vitro. This study explored the feasibility of using ASCs for engineered tendon repair in vivo in a rabbit Achilles tendon model. Total 30 rabbits were involved in this study. A composite tendon scaffold composed of an inner part of polyglycolic acid (PGA) unwoven fibers and an outer part of a net knitted with PGA/PLA (polylactic acid) fibers was used to provide mechanical strength. Autologous ASCs were harvested from nuchal subcutaneous adipose tissues and in vitro expanded. The expanded ASCs were harvested and resuspended in culture medium and evenly seeded onto the scaffold in the experimental group, whereas cell-free scaffolds served as the control group. The constructs of both groups were cultured inside a bioreactor under dynamic stretch for 5 weeks. In each of 30 rabbits, a 2 cm defect was created on right side of Achilles tendon followed by the transplantation of a 3 cm cell-seeded scaffold in the experimental group of 15 rabbits, or by the transplantation of a 3 cm cell-free scaffold in the control group of 15 rabbits. Animals were sacrificed at 12, 21 and 45 weeks post-surgery for gross view, histology, and mechanical analysis. The results showed that short term in vitro culture enabled ASCs to produce matrix on the PGA fibers and the constructs showed tensile strength around 50 MPa in both groups (p > 0.05). With the increase of implantation time, cell-seeded constructs gradually form neo-tendon and became more mature at 45 weeks with histological structure similar to that of native tendon and with the presence of bipolar pattern and D-periodic structure of formed collagen fibrils. Additionally, both collagen fibril diameters and tensile strength increased continuously with significant difference among different time points (p tendon tissue with fibril structure observable only at 45 weeks

  1. Peroneal tendon displacement accompanying intra-articular calcaneal fractures.

    Science.gov (United States)

    Toussaint, Rull James; Lin, Darius; Ehrlichman, Lauren K; Ellington, J Kent; Strasser, Nicholas; Kwon, John Y

    2014-02-19

    Peroneal tendon displacement (subluxation or dislocation) accompanying an intra-articular calcaneal fracture is often undetected and under-treated. The goals of this study were to determine (1) the prevalence of peroneal tendon displacement accompanying intra-articular calcaneal fractures, (2) the association of tendon displacement with fracture classifications, (3) the association of tendon displacement with heel width, and (4) the rate of missed diagnosis of the tendon displacement on radiographs and computed tomography (CT) scans and the resulting treatment rate. A retrospective radiographic review of all calcaneal fractures presenting at three institutions from June 30, 2006, to June 30, 2011, was performed. CT imaging of 421 intra-articular calcaneal fractures involving the posterior facet was available for review. The prevalence of peroneal tendon displacement was noted and its associations with fracture classification and heel width were evaluated. Peroneal tendon displacement was identified in 118 (28.0%) of the 421 calcaneal fracture cases. The presence of tendon displacement was significantly associated with joint-depression fractures compared with tongue-type fractures (p displacement had been identified in the radiology reports. Although sixty-five (55.1%) of the fractures with tendon displacement had been treated with internal fixation, the tendon displacement was treated surgically in only seven (10.8%) of these cases. Analysis of CT images showed a 28% prevalence of peroneal tendon displacement accompanying intra-articular calcaneal fractures. Surgeons and radiologists are encouraged to consider this association.

  2. Effects of plantar-flexor muscle fatigue on the magnitude and regularity of center-of-pressure fluctuations

    NARCIS (Netherlands)

    Roerdink, M.; Hlavackova, P.; Vuillerme, N.

    2011-01-01

    Control of bipedal posture is highly automatized but requires attentional investment, the amount of which varies between participants and with postural constraints, such as plantar-flexor muscle fatigue. Elevated attentional demands for standing with fatigued plantar flexors have been demonstrated

  3. The impact of shoulder abduction loading on EMG-based intention detection of hand opening and closing after stroke.

    Science.gov (United States)

    Lan, Yiyun; Yao, Jun; Dewald, Julius P A

    2011-01-01

    Many stroke patients are subject to limited hand functions in the paretic arm due to a significant loss of Corticospinal Tract (CST) fibers. A possible solution for this problem is to classify surface Electromyography (EMG) signals generated by hand movements and uses that to implement Functional Electrical Stimulation (FES). However, EMG usually presents an abnormal muscle coactivation pattern shown as increased coupling between muscles within and/or across joints after stroke. The resulting Abnormal Muscle Synergies (AMS) could make the classification more difficult in individuals with stroke, especially when attempting to use the hand together with other joints in the paretic arm. Therefore, this study is aimed at identifying the impact of AMS following stroke on EMG pattern recognition between two hand movements. In an effort to achieve this goal, 7 chronic hemiparetic chronic stroke subjects were recruited and asked to perform hand opening and closing movements at their paretic arm while being either fully supported by a virtual table or loaded with 25% of subject's maximum shoulder abduction force. During the execution of motor tasks EMG signals from the wrist flexors and extensors were simultaneously acquired. Our results showed that increased synergy-induced activity at elbow flexors, induced by increasing shoulder abduction loading, deteriorated the performance of EMG pattern recognition for hand opening for those with a weak grasp strength and EMG activity. However, no such impact on hand closing has yet been observed possibly because finger/wrist flexion is facilitated by the shoulder abduction-induced flexion synergy.

  4. Bilateral Tensor Fasciae Suralis Muscles in a Cadaver with Unilateral Accessory Flexor Digitorum Longus Muscle

    Directory of Open Access Journals (Sweden)

    Logan S. W. Bale

    2017-01-01

    Full Text Available Muscle variants are routinely encountered in the dissection laboratory and in clinical practice and therefore anatomists and clinicians need to be aware of their existence. Here we describe two different accessory muscles identified while performing educational dissection of a 51-year-old male cadaver. Tensor fasciae suralis, a rare muscle variant, was identified bilaterally and accessory flexor digitorum longus, a more common muscle variant, was present unilaterally. Tensor fasciae suralis and accessory flexor digitorum longus are clinically relevant muscle variants. To our knowledge, the coexistence of tensor fasciae suralis and accessory flexor digitorum longus in the same individual has not been reported in either cadaveric or imaging studies.

  5. Atypical presentation of GNE myopathy with asymmetric hand weakness

    Science.gov (United States)

    de Dios, John Karl L.; Shrader, Joseph A.; Joe, Galen O.; McClean, Jeffrey C.; Williams, Kayla; Evers, Robert; Malicdan, May Christine V.; Ciccone, Carla; Mankodi, Ami; Huizing, Marjan; McKew, John C.; Bluemke, David A.; Gahl, William A.; Carrillo-Carrasco, Nuria

    2014-01-01

    GNE myopathy is a rare autosomal recessive muscle disease caused by mutations in GNE, the gene encoding the rate-limiting enzyme in sialic acid biosynthesis. GNE myopathy usually manifests in early adulthood with distal myopathy that progresses slowly and symmetrically, first involving distal muscles of the lower extremities, followed by proximal muscles with relative sparing of the quadriceps. Upper extremities are typically affected later in the disease. We report a patient with GNE myopathy who presented with asymmetric hand weakness. He had considerably decreased left grip strength, atrophy of the left anterior forearm and fibro-fatty tissue replacement of left forearm flexor muscles on T1-weighted magnetic resonance imaging. The patient was an endoscopist and thus the asymmetric hand involvement may be associated with left hand overuse in daily repetitive pinching and gripping movements, highlighting the possible impact of environmental factors on the progression of genetic muscle conditions. PMID:25182749

  6. MRI assessment of tenosynovitis in children with juvenile idiopathic arthritis: inter- and intra-observer variability

    International Nuclear Information System (INIS)

    Lambot, Karen; Brunelle, Francis; Boavida, Peter; Damasio, Maria Beatrice; Tanturri de Horatio, Laura; Barbuti, Domenico; Desgranges, Marie; Bader-Meunier, Brigitte; Quartier, Pierre; Malattia, Clara; Bracaglia, Claudia; Ording Mueller, Lil-Sofie; Elie, Caroline; Rosendahl, Karen

    2013-01-01

    There is sparse knowledge about grading tenosynovitis using MRI. The purpose of this study was to assess the reliability of a tenosynovitis MRI scoring system in juvenile idiopathic arthritis. Children with juvenile idiopathic arthritis and wrist involvement were enrolled in two paediatric centres, from October 2006 to January 2010. The extensor (compartments II, IV and VI) and flexor tendons were assessed for the presence of tenosynovitis on T1-weighted postcontrast fat-saturated MR images and were scored from 0 (normal) to 2 (moderate to severe) by two observers independently. Intra- and interobserver agreement was assessed. Ninety children (age range: 5-18.5 years) were included, of whom 34 had tenosynovitis involving extensors and 28 had tenosynovitis involving flexors. A total of 360 tendon areas were analysed, of which 114 had tenosynovitis (86/270 extensors and 28/90 flexors). Intra-reader 1 agreement was excellent for the extensors (k = 0.82-0.91) and for the flexors (k = 0.85); intra-reader 2 agreement was moderate to good for the extensors (k = 0.51-0.72) and good for the flexors (k = 0.64). Inter-reader agreement was good for the extensors (k = 0.69-0.73) and moderate for the flexors (k = 0.49). The proposed MRI scoring system for the assessment of wrist tenosynovitis in juvenile idiopathic arthritis appears feasible with an observer agreement sufficient for clinical use. (orig.)

  7. MRI assessment of tenosynovitis in children with juvenile idiopathic arthritis: inter- and intra-observer variability

    Energy Technology Data Exchange (ETDEWEB)

    Lambot, Karen; Brunelle, Francis [Hopital Necker-Enfants Malades, Department of Paediatric Radiology, Paris (France); Boavida, Peter [Great Ormond Street Hospital, Department of Radiology, London (United Kingdom); Damasio, Maria Beatrice [Ospedale Pediatrico Gaslini, Department of Radiology, Genoa (Italy); Tanturri de Horatio, Laura; Barbuti, Domenico [Ospedale Pediatrico Bambino Gesu, Department of Radiology, Rome (Italy); Desgranges, Marie; Bader-Meunier, Brigitte; Quartier, Pierre [Hopital Necker-Enfants Malades, Department of Paediatric Immunology, Hematology and Rheumatology, APHP French Reference Center ' ' Arthrites juveniles' ' , Paris (France); Malattia, Clara [University of Genoa, Department of Paediatrics, Genoa (Italy); Bracaglia, Claudia [Ospedale Pediatrico Bambino Gesu, Department of Paediatrics, Rome (Italy); Ording Mueller, Lil-Sofie [Great Ormond Street Hospital, Department of Radiology, London (United Kingdom); University Hospital of North Norway, Department of Radiology, Tromsoe (Norway); Elie, Caroline [Paris Descartes University, Department of Biostatistics, Hopital Necker-Enfants Malades, Paris (France); Rosendahl, Karen [Great Ormond Street Hospital, Department of Radiology, London (United Kingdom); Haukeland University Hospital, Department of Radiology, Bergen (Norway)

    2013-07-15

    There is sparse knowledge about grading tenosynovitis using MRI. The purpose of this study was to assess the reliability of a tenosynovitis MRI scoring system in juvenile idiopathic arthritis. Children with juvenile idiopathic arthritis and wrist involvement were enrolled in two paediatric centres, from October 2006 to January 2010. The extensor (compartments II, IV and VI) and flexor tendons were assessed for the presence of tenosynovitis on T1-weighted postcontrast fat-saturated MR images and were scored from 0 (normal) to 2 (moderate to severe) by two observers independently. Intra- and interobserver agreement was assessed. Ninety children (age range: 5-18.5 years) were included, of whom 34 had tenosynovitis involving extensors and 28 had tenosynovitis involving flexors. A total of 360 tendon areas were analysed, of which 114 had tenosynovitis (86/270 extensors and 28/90 flexors). Intra-reader 1 agreement was excellent for the extensors (k = 0.82-0.91) and for the flexors (k = 0.85); intra-reader 2 agreement was moderate to good for the extensors (k = 0.51-0.72) and good for the flexors (k = 0.64). Inter-reader agreement was good for the extensors (k = 0.69-0.73) and moderate for the flexors (k = 0.49). The proposed MRI scoring system for the assessment of wrist tenosynovitis in juvenile idiopathic arthritis appears feasible with an observer agreement sufficient for clinical use. (orig.)

  8. Towards a parameterizable exoskeleton for training of hand function after stroke.

    Science.gov (United States)

    Weiss, Patrick; Heyer, Lars; Munte, Thomas F; Heldmann, Marcus; Schweikard, Achim; Maehle, Erik

    2013-06-01

    This paper describes the mechanical design, actuation and sensing of an exoskeleton for hand function training after stroke. The frame is 3D-printed in one piece including the joints. Apart from saving assembly time, this enables parametrization of the link sizes in order to adapt it to the patient's hand and reduce joint misalignment. The joint angles are determined using Hall effect sensors. They measure the change of the magnetic field of in the joints integrated magnets achieving an average accuracy of 1.25 °. Tendons attached to the finger tips transmit forces from motors. The armature current, which is proportional to the force transmitting tendons is measured using a shunt and controlled by a custom-made current-limiter circuit. Preliminary experiments with a force/torque-sensor showed high linearity and accuracy with a root mean square error of 0.5937 N in comparison to the corresponding forces derived from the motor torque constant.

  9. The 'bridging sign', a MR finding for combined full-thickness tears of the subscapularis tendon and the supraspinatus tendon

    International Nuclear Information System (INIS)

    Jung, Jin Young; Yoon, Young Cheol; Cha, Dong Ik; Yoo, Jae-Chul; Jung, Jee Young

    2013-01-01

    Background: In daily practice, we discovered one of the secondary magnetic resonance (MR) findings of the subscapularis (SSC) tendon tear, the 'bridging sign', which has not been previously described. Purpose: To describe the 'bridging sign' on shoulder MR imaging and its radiological and clinical significance in patients with SSC tendon tear. Material and Methods: Twenty-nine patients who had undergone shoulder arthroscopy and had full-thickness tear of the subscapularis tendon were enrolled. The medical records of the 29 patients were retrospectively reviewed for the duration of shoulder pain, rotator cuff tears, and associated arthroscopic findings: biceps tendon abnormality and superior glenoid labral tear. Then, preoperative shoulder MR images were retrospectively reviewed for the presence or absence of the 'bridging sign' and associated MR findings: periarticular fluid and fatty atrophy of the supraspinatus and subscapularis muscles. The type of rotator cuff tear associated with the 'bridging sign' was assessed and the sensitivity, specificity, and accuracy of the 'bridging sign' for the diagnosis of a certain type of rotator cuff tear were calculated. Associated arthroscopic and MR findings and mean duration of the shoulder pain between the patients with and without the 'bridging sign' were compared. Results: The 'bridging sign' was seen in 17 of 29 patients and corresponded to a complex of the torn and superomedially retracted subscapularis tendon, coracohumeral ligament, and superior glenohumeral ligament, adhered to the anterior margin of the torn supraspinatus (SSP) tendon on arthroscopy. All patients with the 'bridging sign' had combined full-thickness tear (FTT) of the cranial 1/2 portion of the subscapularis tendon and anterior 1/2 portion of the SSP tendon. The sensitivity, specificity, and accuracy of the 'bridging sign' for the diagnosis of combined FTTs of the SSC tendon and anterior portion of the SSP tendon were 81.0%, 100%, and 86

  10. Resistance exercise prevents plantar flexor deconditioning during bed rest

    Science.gov (United States)

    Bamman, M. M.; Hunter, G. R.; Stevens, B. R.; Guilliams, M. E.; Greenisen, M. C.

    1997-01-01

    Because resistance exercise (REX) and unloading induce opposing neuromuscular adaptations, we tested the efficacy of REX against the effects of 14 d of bed rest unloading (BRU) on the plantar flexor muscle group. Sixteen men were randomly assigned to no exercise (NOE, N = 8) or REX (N = 8). REX performed 5 sets x 6-10 repetitions to failure of constant resistance concentric/eccentric plantar flexion every other day during BRU. One-repetition maximum (1RM) strength was tested on the training device. The angle-specific torque-velocity relationship across 5 velocities (0, 0.52, 1.05, 1.75, and 2.97 rad.s-1) and the full range-of-motion power-velocity relationship were assessed on a dynamometer. Torque-position analyses identified strength changes at shortened, neutral, and stretched muscle lengths. Concentric and eccentric contractile work were measured across ten repetitions at 1.05 rad.s-1. Maximal neural activation was measured by surface electromyography (EMG). 1RM decreased 9% in NOE and improved 11% in REX (P joint positions. Concentric (15%) and eccentric (11%) contractile work fell in NOE (P < 0.05) but not in REX. Maximal plantar flexor EMG did not change in either group. In summary, constant resistance concentric/eccentric REX completely prevented plantar flexor performance deconditioning induced by BRU. The reported benefits of REX should prove useful in prescribing exercise for astronauts in microgravity and for patients susceptible to functional decline during bed- or chair-bound hospital stays.

  11. Fetal development of the pulley for muscle insertion tendons: A review and new findings related to the tensor tympani tendon.

    Science.gov (United States)

    Rodríguez-Vázquez, Jose Francisco; Honkura, Yohei; Katori, Yukio; Murakami, Gen; Abe, Hiroshi

    2017-01-01

    The existence of hard tissue pulleys that act to change the direction of a muscle insertion tendon is well known in the human body. These include (1) the trochlea for the extraocular obliquus superior muscle, (2) the pterygoid hamulus for the tensor veli palatini muscle, (3) the deep sulcus on the plantar aspect of the cuboid bone for the peroneus longus tendon, (4) the lesser sciatic notch for the obturator internus muscle, and (5) the bony trochleariformis process for the tensor tympani muscle tendon. In addition, (6) the stapedius muscle tendon shows a lesser or greater angulation at the pyramidal eminence of the temporal bone. Our recent studies have shown that the development of pulleys Nos. 1 and 2 can be explained by a change in the topographical relationship between the pulley and the tendon, that of pulley No. 3 by the rapidly growing calcaneus pushing the tendon, and that of pulley No. 4 by migration of the insertion along the sciatic nerve and gluteus medius tendon. Therefore, in Nos. 1-4, an initially direct tendon curves secondarily and obtains an attachment to the pulley. In case No. 6, the terminal part of the stapedius tendon originates secondarily from the interzone mesenchymal tissue of the incudostapedial joint. In the case of pulley No. 5, we newly demonstrated that its initial phase of development was similar to No. 6, but the tensor tympani tendon achieved a right-angled turn under guidance by a specific fibrous tissue and it migrated along the growing malleus manubrium. Copyright © 2016 Elsevier GmbH. All rights reserved.

  12. Imaging the infrapatellar tendon in the elite athlete

    International Nuclear Information System (INIS)

    Peace, K.A.L.; Lee, J.C.; Healy, J.

    2006-01-01

    Extensor mechanism injuries constitute a major cause of anterior knee pain in the elite athlete. Sonography and magnetic resonance imaging (MRI) are the imaging methods of choice when assessing the infrapatellar tendon. A comprehensive imaging review of infrapatellar tendon normal anatomy, tendinopathy, and partial/full-thickness tendon tears is provided. The value of imaging the infrapatellar tendon in clinical practice, including whether sonography can predict symptoms in asymptomatic athletes, is discussed. Acute avulsion fractures, including periosteal sleeve avulsion, and chronic avulsion injuries, including Sinding-Larsen-Johansson and Osgood-Schlatter syndromes, are shown. Mimics of infrapatellar tendon pathology, including infrapatellar plica injury, patellar tendon-lateral femoral condyle friction syndrome, and Hoffa's syndrome, are illustrated

  13. About tendon tissue regeneration in experimental radiation disease

    Energy Technology Data Exchange (ETDEWEB)

    Popov, D; Trichkova, P

    1976-01-01

    Under the conditions of experimental acute radiation disease the authors study the tendon tissue regeneration after suture of the lateral part of the gastrocnemius muscle tendon. Tendon auto and alloplasty were applied. In four postoperative periods the histological features are described in details as well as the characteristic phenomena observed during the regeneration influenced to a considerable degree by the irradiation. Round cell infiltration, large necrotic zones, erythrocyte infiltrations as well as predominance of non-specific tendon regeneration long after the surgery characterize the recovery period of the traumatically damaged tendon, nevertheless that at the end there is real tendon regeneration even though in a longer period in comparison with the controls (non-irradiated animals).

  14. Spontaneous Achilles tendon rupture in alkaptonuria | Mohammed ...

    African Journals Online (AJOL)

    Spontaneous Achilles tendon ruptures are uncommon. We present a 46-year-old man with spontaneous Achilles tendon rupture due to ochronosis. To our knowledge, this has not been previously reported in Sudan literature. The tendon of the reported patient healed well after debridement and primary repairs.

  15. Plantar tendons of the foot: MR imaging and US.

    Science.gov (United States)

    Donovan, Andrea; Rosenberg, Zehava Sadka; Bencardino, Jenny T; Velez, Zoraida Restrepo; Blonder, David B; Ciavarra, Gina A; Adler, Ronald Steven

    2013-01-01

    Tendon disorders along the plantar aspect of the foot may lead to significant symptoms but are often clinically misdiagnosed. Familiarity with the normal anatomy of the plantar tendons and its appearance at magnetic resonance (MR) imaging and ultrasonography (US) is essential for recognizing plantar tendon disorders. At MR imaging, the course of the plantar tendons is optimally visualized with dedicated imaging of the midfoot and forefoot. This imaging should include short-axis images obtained perpendicular to the long axis of the metatarsal shafts, which allows true cross-sectional evaluation of the plantar tendons. Normal plantar tendons appear as low-signal-intensity structures with all MR sequences. At US, accurate evaluation of the tendons requires that the ultrasound beam be perpendicular to the tendon. The normal tendon appears as a compact linear band of echogenic tissue that contains a fine, mixed hypoechoic and hyperechoic internal fibrillar pattern. Tendon injuries can be grouped into six major categories: tendinosis, peritendinosis, tenosynovitis, entrapment, rupture, and instability (subluxation or dislocation) and can be well assessed with both MR imaging and US. The radiologist plays an important role in the diagnosis of plantar tendon disorders, and recognizing their imaging appearances at MR imaging and US is essential.

  16. Degree of thoracic kyphosis and peak torque of trunk flexors and extensors among healthy women.

    Science.gov (United States)

    Granito, Renata Neves; Aveiro, Mariana Chaves; Rennó, Ana Claudia Muniz; Oishi, Jorge; Driusso, Patricia

    2014-01-01

    The aim of this study was to analyze the effects of aging on the degree of thoracic kyphosis and peak torque of the trunk flexor and extensor muscles among women without a densitometric diagnosis of osteoporosis. Thirty women were selected to make up three groups: young women (n = 10; 24.60 ± 2.27 years of age); adults (n = 10; 43.50 ± 2.88); and elderly women (n = 10; 62.40 ± 2.67). Bone mineral density (BMD), degree of thoracic kyphosis and peak torque of the trunk flexors and extensors were evaluated. Differences between the groups were evaluated using the Kruskal-Wallis ANOVA and Mann-Whitney U tests. Pearson's correlation coefficient was used to assess correlations between the variables. The significance level was taken to be 5% (p ≤ 0.05). The elderly group presented a greater degree of thoracic kyphosis (p = 0.009) and lower peak torque of the trunk flexors and extensors than the young group. The adult group presented lower peak torque of the trunk than the young group. A negative correlation was observed between age and peak torque of the trunk flexors and extensors (p ≤ 0.001), and a positive correlation between age and the degree of thoracic kyphosis (r = 0.58; p ≤ 0.001). The elderly group presented higher values for the eccentric/concentric ratio of the peak torque for flexors (p = 0.03) and extensors (p = 0.02). This study suggests that physiological aging may be associated with a greater degree of thoracic kyphosis and lower muscle strength of the trunk flexors and extensors. Moreover, the elderly women showed a relative capacity for preservation of eccentric strength.

  17. Degree of thoracic kyphosis and peak torque of trunk flexors and extensors among healthy women,

    Directory of Open Access Journals (Sweden)

    Renata Neves Granito

    2014-06-01

    Full Text Available OBJECTIVE: The aim of this study was to analyze the effects of aging on the degree of thoracic kyphosis and peak torque of the trunk flexor and extensor muscles among women without a densitometric diagnosis of osteoporosis.METHODS: Thirty women were selected to make up three groups: young women (n = 10; 24.60 ± 2.27 years of age; adults (n = 10; 43.50 ± 2.88; and elderly women (n= 10; 62.40 ± 2.67. Bone mineral density (BMD, degree of thoracic kyphosis and peak torque of the trunk flexors and extensors were evaluated. Differences between the groups were evaluated using the Kruskal-Wallis ANOVA and Mann-Whitney U tests. Pearson's correlation coefficient was used to assess correlations between the variables. The significance level was taken to be 5% (p < 0.05.RESULTS: The elderly group presented a greater degree of thoracic kyphosis (p = 0.009 and lower peak torque of the trunk flexors and extensors than the young group. The adult group presented lower peak torque of the trunk than the young group. A negative correlation was observed between age and peak torque of the trunk flexors and extensors (p < 0.001, and a positive correlation between age and the degree of thoracic kyphosis (r = 0.58; p < 0.001. The elderly group presented higher values for the eccentric/concentric ratio of the peak torque for flexors (p = 0.03 and extensors (p = 0.02.CONCLUSION: This study suggests that physiological aging may be associated with a greater degree of thoracic kyphosis and lower muscle strength of the trunk flexors and extensors. Moreover, the elderly women showed a relative capacity for preservation of eccentric strength.

  18. Mechanical properties of the human Achilles tendon, in vivo

    DEFF Research Database (Denmark)

    Kongsgaard, M; Nielsen, C H; Hegnsvad, S

    2011-01-01

    Ultrasonography has been widely applied for in vivo measurements of tendon mechanical properties. Assessments of human Achilles tendon mechanical properties have received great interest. Achilles tendon injuries predominantly occur in the tendon region between the Achilles-soleus myotendinous...... junction and Achilles-calcaneus osteotendinous junction i.e. in the free Achilles tendon. However, there has been no adequate ultrasound based method for quantifying the mechanical properties of the free human Achilles tendon. This study aimed to: 1) examine the mechanical properties of the free human...

  19. Home-based hand rehabilitation with a robotic glove in hemiplegic patients after stroke: a pilot feasibility study.

    Science.gov (United States)

    Bernocchi, Palmira; Mulè, Chiara; Vanoglio, Fabio; Taveggia, Giovanni; Luisa, Alberto; Scalvini, Simonetta

    2018-03-01

    To evaluate the feasibility and safety of home rehabilitation of the hand using a robotic glove, and, in addition, its effectiveness, in hemiplegic patients after stroke. In this non-randomized pilot study, 21 hemiplegic stroke patients (Ashworth spasticity index ≤ 3) were prescribed, after in-hospital rehabilitation, a 2-month home-program of intensive hand training using the Gloreha Lite glove that provides computer-controlled passive mobilization of the fingers. Feasibility was measured by: number of patients who completed the home-program, minutes of exercise and number of sessions/patient performed. Safety was assessed by: hand pain with a visual analog scale (VAS), Ashworth spasticity index for finger flexors, opponents of the thumb and wrist flexors, and hand edema (circumference of forearm, wrist and fingers), measured at start (T0) and end (T1) of rehabilitation. Hand motor function (Motricity Index, MI), fine manual dexterity (Nine Hole Peg Test, NHPT) and strength (Grip test) were also measured at T0 and T1. Patients performed, over a mean period 56 (49-63) days, a total of 1699 (1353-2045) min/patient of exercise with Gloreha Lite, 5.1 (4.3-5.8) days/week. Seventeen patients (81%) completed the full program. The mean VAS score of hand pain, Ashworth spasticity index and hand edema did not change significantly at T1 compared to T0. The MI, NHPT and Grip test improved significantly (p = 0.0020, 0.0156 and 0.0024, respectively) compared to baseline. Gloreha Lite is feasible and safe for use in home rehabilitation. The efficacy data show a therapeutic effect which need to be confirmed by a randomized controlled study.

  20. Forearm Flexor Muscles in Children with Cerebral Palsy Are Weak, Thin and Stiff

    Directory of Open Access Journals (Sweden)

    Eva Pontén

    2017-04-01

    Full Text Available Children with cerebral palsy (CP often develop reduced passive range of motion with age. The determining factor underlying this process is believed to be progressive development of contracture in skeletal muscle that likely changes the biomechanics of the joints. Consequently, to identify the underlying mechanisms, we modeled the mechanical characteristics of the forearm flexors acting across the wrist joint. We investigated skeletal muscle strength (Grippit® and passive stiffness and viscosity of the forearm flexors in 15 typically developing (TD children (10 boys/5 girls, mean age 12 years, range 8–18 yrs and nine children with CP Nine children (6 boys/3 girls, mean age 11 ± 3 years (yrs, range 7–15 yrs using the NeuroFlexor® apparatus. The muscle stiffness we estimate and report is the instantaneous mechanical response of the tissue that is independent of reflex activity. Furthermore, we assessed cross-sectional area of the flexor carpi radialis (FCR muscle using ultrasound. Age and body weight did not differ significantly between the two groups. Children with CP had a significantly weaker (−65%, p < 0.01 grip and had smaller cross-sectional area (−43%, p < 0.01 of the FCR muscle. Passive stiffness of the forearm muscles in children with CP was increased 2-fold (p < 0.05 whereas viscosity did not differ significantly between CP and TD children. FCR cross-sectional area correlated to age (R2 = 0.58, p < 0.01, body weight (R2 = 0.92, p < 0.0001 and grip strength (R2 = 0.82, p < 0.0001 in TD children but only to grip strength (R2 = 0.60, p < 0.05 in children with CP. We conclude that children with CP have weaker, thinner, and stiffer forearm flexors as compared to typically developing children.

  1. Variants, pitfalls and asymptomatic findings in wrist and hand imaging

    Energy Technology Data Exchange (ETDEWEB)

    Pfirrmann, Christian W.A. [University Hospital Balgrist, Radiology, University of Zurich Switzerland, Forchstrasse 340, CH-8008 Zurich (Switzerland)]. E-mail: christian@pfirrmann.ch; Zanetti, Marco [University Hospital Balgrist, Radiology, University of Zurich Switzerland, Forchstrasse 340, CH-8008 Zurich (Switzerland)

    2005-12-15

    Anatomic variants of the bones, ligaments, tendons and muscles are frequent findings in imaging of the wrist and hand. Many findings especially changes in the triangular fibrocartilage (TFC) and the interosseous ligaments are asymptomatic, their incidence is increasing with age, and they are frequently found bilaterally. Abnormalities such as increased signal within tendons are common in asymptomatic subjects. They may be explained by normal physiology, anatomical variability, MR artifacts or true abnormalities without clinical importance. Although it is not always possible to differentiate variants and artifacts from clinically relevant findings it is important to know their potential etiology and clinical importance and not to over report them as abnormality requiring additional imaging or treatment.

  2. A Tendon Cell Specific RNAi Screen Reveals Novel Candidates Essential for Muscle Tendon Interaction.

    Directory of Open Access Journals (Sweden)

    Prabhat Tiwari

    Full Text Available Tendons are fibrous connective tissue which connect muscles to the skeletal elements thus acting as passive transmitters of force during locomotion and provide appropriate body posture. Tendon-derived cues, albeit poorly understood, are necessary for proper muscle guidance and attachment during development. In the present study, we used dorsal longitudinal muscles of Drosophila and their tendon attachment sites to unravel the molecular nature of interactions between muscles and tendons. We performed a genetic screen using RNAi-mediated knockdown in tendon cells to find out molecular players involved in the formation and maintenance of myotendinous junction and found 21 candidates out of 2507 RNAi lines screened. Of these, 19 were novel molecules in context of myotendinous system. Integrin-βPS and Talin, picked as candidates in this screen, are known to play important role in the cell-cell interaction and myotendinous junction formation validating our screen. We have found candidates with enzymatic function, transcription activity, cell adhesion, protein folding and intracellular transport function. Tango1, an ER exit protein involved in collagen secretion was identified as a candidate molecule involved in the formation of myotendinous junction. Tango1 knockdown was found to affect development of muscle attachment sites and formation of myotendinous junction. Tango1 was also found to be involved in secretion of Viking (Collagen type IV and BM-40 from hemocytes and fat cells.

  3. Simultaneous bilateral patellar tendon rupture.

    Science.gov (United States)

    Moura, Diogo Lino; Marques, José Pedro; Lucas, Francisco Manuel; Fonseca, Fernando Pereira

    2017-01-01

    Bilateral patellar tendon rupture is a rare entity, often associated with systemic diseases and patellar tendinopathy. The authors report a rare case of a 34-year-old man with simultaneous bilateral rupture of the patellar tendon caused by minor trauma. The patient is a retired basketball player with no past complaints of chronic knee pain and a history of steroid use. Surgical management consisted in primary end-to-end tendon repair protected temporarily with cerclage wiring, followed by a short immobilization period and intensive rehabilitation program. Five months after surgery, the patient was able to fully participate in sport activities.

  4. Rupture of Achilles Tendon : Usefulness of Ultrasonography

    International Nuclear Information System (INIS)

    Kim, Nam Hyeon; Ki, Won Woo; Yoon, Kwon Ha; Kim, Song Mun; Shin, Myeong Jin; Kwon, Soon Tae

    1996-01-01

    To differentiate a complete rupture of Achilles tendon from an incomplete one which is important because its treatment is quite different. And it is necessary to know the exact site of the rupture preoperatively. Fifteen cases of fourteen patients which were diagnosed as Achilles tendon rupture by ultrasonography and surgery were reviewed. We compared sonographic rupture site with surgical findings. Ultrasonographic criteria for differentiation of complete and incomplete rupture was defined as follows : the discreteness, which means the proximal intervening hypoechogenicity to the interface echogenicity of distal margin of ruptured tendon : the slant sign, which represents the interface of ruptured distal margin which was seen over the 3/4 of the thickness of the tendon without intervening low echogeneicity : the invagination sign, which means the echogenic invagination from Kager triangle into posterior aspect of Achilles tendon over the half thickness of the tendon. The sites of complete tendon rupture were exactly corresponded to surgical finding in four cases of ten complete ruptures. And the discrepancy between sonographic and surgical findings in the site of complete rupture was 1.2 ± 0.4 cm in six cases. Three of ten complete ruptures showed the discreteness sign, all of ten showed the slant sign and two of ten showed the invagination sign. It is helpful to differentiate a complete from incomplete rupture of the Achilles tendon and to localize the site of the complete rupture with the ultrasonographic evaluation

  5. Effect of estrogen on tendon collagen synthesis, tendon structural characteristics, and biomechanical properties in postmenopausal women

    DEFF Research Database (Denmark)

    Hansen, Mette; Kongsgaard, Mads; Holm, Lars

    2009-01-01

    and fibril characteristics were determined by MRI and transmission electron microscopy, whereas tendon biomechanical properties were measured during isometric maximal voluntary contraction by ultrasound recording. Tendon FSR was markedly higher in ERT-users (P

  6. Eccentric Knee Flexor Strength and Risk of Hamstring Injuries in Rugby Union: A Prospective Study.

    Science.gov (United States)

    Bourne, Matthew N; Opar, David A; Williams, Morgan D; Shield, Anthony J

    2015-11-01

    Hamstring strain injuries (HSIs) represent the most common cause of lost playing time in rugby union. Eccentric knee flexor weakness and between-limb imbalance in eccentric knee flexor strength are associated with a heightened risk of HSIs in other sports; however, these variables have not been explored in rugby union. To determine if lower levels of eccentric knee flexor strength or greater between-limb imbalance in this parameter during the Nordic hamstring exercise are risk factors for HSIs in rugby union. Cohort study; Level of evidence, 2. This prospective study was conducted over the 2014 Super Rugby and Queensland Rugby Union seasons. In total, 178 rugby union players (mean age, 22.6 ± 3.8 years; mean height, 185.0 ± 6.8 cm; mean weight, 96.5 ± 13.1 kg) had their eccentric knee flexor strength assessed using a custom-made device during the preseason. Reports of previous hamstring, quadriceps, groin, calf, and anterior cruciate ligament injuries were also obtained. The main outcome measure was the prospective occurrence of HSIs. Twenty players suffered at least 1 HSI during the study period. Players with a history of HSIs had a 4.1-fold (95% CI, 1.9-8.9; P = .001) greater risk of subsequent HSIs than players without such a history. Between-limb imbalance in eccentric knee flexor strength of ≥15% and ≥20% increased the risk of HSIs by 2.4-fold (95% CI, 1.1-5.5; P = .033) and 3.4-fold (95% CI, 1.5-7.6; P = .003), respectively. Lower eccentric knee flexor strength and other prior injuries were not associated with an increased risk of future HSIs. Multivariate logistic regression revealed that the risk of reinjuries was augmented in players with strength imbalances. Previous HSIs and between-limb imbalance in eccentric knee flexor strength were associated with an increased risk of future HSIs in rugby union. These results support the rationale for reducing imbalance, particularly in players who have suffered a prior HSI, to mitigate the risk of future

  7. Investigations related to failure of prestressing tendons

    International Nuclear Information System (INIS)

    Boyadjiev, Z.

    1995-01-01

    Kozloduy NPP units 5 and 6 containment cladding shells are prestressed by the use of tendons 450 φ 5, made of high strength wires, class B-II. The prestressing force for each tendon is 10000 kN and the calculated breakdown force - 14000 kN. There are 96 tendons in the cylindrical part of the shell and 36 ones located in the containment dome. They are located in channel forming tubes of inner diameter of 200 mm, made of dense polyethylene. In order to assure biaxial prestressed condition, the prestressing tendons are located on screw shaped lines, both left and right, with declination to the horizon 35 degrees and 15 minutes. Each prestressing tendon initially forms a knee and following the bending at elevation + 10.80 m forms the other knee, in such a way, that its two ends are anchored in one and the same area-in a common or adjacent upper anchor boxes. The prestressing tendons in the containment dome are located in two perpendicular rows. Both ends of each tendon are anchored in a common fixing, the tendon being bent to the opposite side of the dome. During construction and operation of units 5 and 6, it was found, that the design prestressing force of 10000 kN can not be reached with some tendons, due to separate wires ruptures or due to the anchoring screw spent thread. The 1992 preliminary wires tests on a failed tendon found out deformation properties, different from the systematically obtained ones for the initial steel. Taking into consideration this fact, together with the IAEA regional project, concerning WWER-1000 seismic safety and items 4 and 6 of Kozloduy NPP Technical Council decisions of 10 June 1993, brought to delegation to the Research Construction Institute the performance of the technical analysis of the applied system for shell prestressing of containments of of units 5 and 6. The analysis comprises physical-mechanical and rheological properties of the high strength wires, used for containment shell prestressing and the over all technological

  8. Glutaraldehyde cross-linking of tendon mechanical effects at the level of the tendon fascicle and fibril

    DEFF Research Database (Denmark)

    Hansen, Philip; Hassenkam, Tue; Svensson, Rene Bruggebusch

    2009-01-01

    at the tendon fibril level were examined by atomic force microscopy. Peak forces increased from approximately 1379 to approximately 2622 pN while an extended Hertz fit of force-indentation data showed a approximately 24 fold increase in Young's modulus on indentation. The effect of glutaraldehyde cross......Conclusive insight into the microscopic principles that govern the strength of tendon and related connective tissues is lacking and the importance of collagen cross-linking has not been firmly established. The combined application of whole-tissue mechanical testing and atomic force spectroscopy...... allowed for a detailed characterization of the effect of cross-linking in rat-tail tendon. The cross-link inducing agent glutaraldehyde augmented the tensile strength of tendon fascicles. Stress at failure increased from approximately 8 MPa to approximately 39 MPa. The mechanical effects of glutaraldehyde...

  9. THE ROLE OF DETRAINING IN TENDON MECHANOBIOLOGY

    Directory of Open Access Journals (Sweden)

    Antonio eFrizziero

    2016-02-01

    Full Text Available Introduction: Several conditions such as training, aging, estrogen deficiency and drugs could affect the biological and anatomo-physiological characteristics of the tendon. Additionally, recent preclinical and clinical studies examined the effect of detraining on tendon, showing alterations in its structure and morphology and in tenocyte mechanobiology. However, there is a paucity of data examining the impact that cessation of training may have on tendon. In practice, we do not fully understand how tendons respond to a period of training followed by sudden detraining. Therefore, within this review, we summarize the studies where tendon detraining was examined.Materials and methods: A descriptive systematic literature review was conducted by searching three databases (PubMed, Scopus and Web of Knowledge on tendon detraining. Original articles in English from 2000 to 2015 were included. In addition, the search was extended to the reference lists of the selected articles. A public reference manager (www.mendeley.com was used to delete duplicate articles.Results: An initial literature search yielded 134 references (www.pubmed.org: 53; www.scopus.com: 11; www.webofknowledge.com: 70. 15 publications were extracted based on the title for further analysis by two independent reviewers. Abstracts and whole articles were then reviewed to detect if they met inclusion criteria.Conclusions: The revised literature comprised 4 clinical studies and an in vitro and three in vivo reports. Overall, the results showed that tendon structure and properties after detraining are compromised, with an alteration in the tissue structural organization and mechanical properties. Clinical studies usually showed a lesser extent of tendon alterations, probably because preclinical studies permit an in-depth evaluation of tendon modifications, which is hard to perform in human subjects. In conclusion, after a period of sudden detraining (e.g. after an injury, physical activity

  10. Local trauma in human patellar tendon leads to widespread changes in the tendon gene expression

    DEFF Research Database (Denmark)

    Heinemeier, Katja Maria; Lorentzen, Marc P; Kildevang Jensen, Jacob

    2016-01-01

    Low cellular activity and slow tissue turnover in human tendon may prolong resolution of tendinopathy. This may be stimulated by moderate localized traumas such as needle penetrations, but whether this results in a widespread cellular response in tendons is unknown. In an initial hypothesis-gener...

  11. Tendon overuse syndrome: imaging diagnosis

    International Nuclear Information System (INIS)

    Huber, W.; Nehrer, S.; Muellner, T.; Kainberger, F.; Ulreich, N.; Bernhard, C.; Imhof, H.

    2001-01-01

    Injuries of muscles and tendons occur commonly during various sporting activities and in most cases the athletes feel such an accident to be sudden and unavoidable. The rupture of a tendon, however, has to be considered in many cases as the final stage of a long-standing progressive degeneration of collagen fibers. This process con be described as 'tendon overuse syndrome (TOS)'. Diagnostic imaging modalities, especially sonography and MRI, are suitable to detect and analyse the different stages of this syndrome and the degree of morphological abnormalities. The first stage is painful functional derangement, followed by tendovaginitis, peritendinitis, or bursitis. The third stage is tendinosis resulting from biomechanical or ischaemic injury of tendon fibers which may eventually be followed by partial or complete rupture. Regional or individual specifications of these four stages may occur at anatomically predisposing sites, so-called critical zones, or during periods of specific proneness, the vulnerable phases. (author)

  12. Bio-inspired mechanical design of a tendon-driven dexterous prosthetic hand.

    Science.gov (United States)

    Controzzi, Marco; Cipriani, Christian; Jehenne, Beryl; Donati, Marco; Carrozza, Maria Chiara

    2010-01-01

    This paper presents the preliminary design of a new dexterous upper-limb prosthesis provided with a novel anthropomorphic hand, a compact wrist based on bevel gears and a modular forearm able to cover different levels of upper-limb amputations. The hand has 20 DoFs and 11 motors, with a dexterous three fingered subsystem composed by a fully actuated thumb, and an hybrid index and middle fingers to enable dexterous manipulation and enhance grasp performance.

  13. Robot Arm with Tendon Connector Plate and Linear Actuator

    Science.gov (United States)

    Ihrke, Chris A. (Inventor); Diftler, Myron A. (Inventor); Bridgwater, Lyndon (Inventor); Nguyen, Vienny (Inventor); Millerman, Alexander (Inventor)

    2014-01-01

    A robotic system includes a tendon-driven end effector, a linear actuator, a flexible tendon, and a plate assembly. The linear actuator assembly has a servo motor and a drive mechanism, the latter of which translates linearly with respect to a drive axis of the servo motor in response to output torque from the servo motor. The tendon connects to the end effector and drive mechanism. The plate assembly is disposed between the linear actuator assembly and the tendon-driven end effector and includes first and second plates. The first plate has a first side that defines a boss with a center opening. The second plate defines an accurate through-slot having tendon guide channels. The first plate defines a through passage for the tendon between the center opening and a second side of the first plate. A looped end of the flexible tendon is received within the tendon guide channels.

  14. The value of immersion hand radiography in soft tissue changes of musculoskeletal disorders

    International Nuclear Information System (INIS)

    Ngo, C.; Yaghmai, I.

    1988-01-01

    Immersion hand radiographs were performed on 25 patients with various clinical presentations and compared to plain radiographic studies of the hands. The immersion technique is superior in outlining the skin, subcutaneous fat layers, and fat layers between muscle planes. More important, this technique highlights the tendons and soft tissue components of the joint, which are hardly seen on standard hand radiographs. Immersion studies are therefore useful, both in the early diagnosis of erosive arthritis and in the follow-up of the course of the disease. They are recommended as an adjunct to conventional hand radiography in musculoskeletal disorders with soft tissue involvement. (orig.)

  15. Modeling of hand function by mapping the motion of individual muscle voxels with MR imaging velocity tagging

    International Nuclear Information System (INIS)

    Drace, J.; Pele, N.; Herfkens, R.J.

    1990-01-01

    This paper reports on a method to correlate the three-dimensional (3D) motion of the fingers with the complex motion of the intrinsic, flexor, and extensor muscles. A better understanding of hand function is important to the medical, surgical, and rehabilitation treatment of patients with arthritic, neurogenic, and mechanical hand dysfunctions. Static, high-resolution MR volumetric imaging defines the 3D shape of each individual bone in the hands of three subjects and three patients. Single-section velocity-tagging sequences (VIGOR) are performed through the hand and forearm, while the actual 3D motion of the hand is computed from the MR model and readings of fiber-optic goniometers attached to each finger. The accuracy of the velocity tagging is also tested with a motion phantom

  16. Shortened stapedius tendon: a rare cause of conductive hearing loss.

    Science.gov (United States)

    Zawawi, F; Varshney, R; Schloss, M D

    2014-01-01

    Anomalies of the stapedius tendon have been reported to cause conductive hearing loss; in theory, such anomalies limit the movement of the stapes. To demonstrate a rare cause of conductive hearing loss resulting from anomaly of the stapedius tendon and to compare the clinical findings of this patient to other stapedius tendon anomalies reported in the literature. Case report of a single case of shortened stapedius tendon and a review of the English literature on stapedius tendon anomalies. This is a case report of a 15-year-old boy with shortened stapedius tendon causing unilateral hearing loss, accompanied by a review of the literature. Contrary to other reported cases, this patient did not have an ossified tendon, but rather an extremely short tendon. The boy regained normal hearing following excision of the stapedius tendon. A shortened stapedius tendon is a very rare diagnosis, yet it should be considered as a possible cause of conductive hearing loss.

  17. Accuracy of MRI technique in measuring tendon cross-sectional area

    DEFF Research Database (Denmark)

    Couppé, Christian; Svensson, R. B.; Elbrønd (Bibs), Vibeke Sødring

    2014-01-01

    , but the accuracy in relation to actual tendon dimensions has never been investigated. The purpose of this study was to compare tendon CSA measured by MRI with that measured in vitro with the mould casting technique. The knee of a horse was MRI-scanned with 1.5 and 3 tesla, and two examiners measured the patellar...... tendon CSA. Thereafter, the patellar tendon of the horse was completely dissected and embedded in an alginate cast. The CSA of the embedded tendon was measured directly by optical imaging of the cast impression. 1.5 tesla grey tendon CSA and 3 tesla grey tendon CSA were 16.5% and 13.2% lower than...... the mould tendon CSA, respectively. Also, 3 tesla tendon CSA, based on the red-green border on the National Institute of Health (NIH) colour scale, was lower than the mould tendon CSA by 2.8%. The typical error between examiners was below 2% for all the measured CSA. The typical error between examiners...

  18. The blood-tendon barrier: identification and characterisation of a novel tissue barrier in tendon blood vessels

    Directory of Open Access Journals (Sweden)

    C Lehner

    2016-05-01

    Full Text Available Tissue barriers function as “gate keepers” between different compartments (usually blood and tissue and are formed by specialised membrane-associated proteins, localising to the apicolateral plasma membrane domain of epithelial and endothelial cells. By sealing the paracellular space, the free diffusion of solutes and molecules across epithelia and endothelia is impeded. Thereby, tissue barriers contribute to the establishment and maintenance of a distinct internal and external environment, which is crucial during organ development and allows maintenance of an organ-specific homeostatic milieu. So far, various epithelial and endothelial tissue barriers have been described, including the blood-brain barrier, the blood-retina barrier, the blood-testis barrier, the blood-placenta barrier, and the cerebrospinal fluid (CSF-brain barrier, which are vital for physiological function and any disturbance of these barriers can result in severe organ damage or even death. Here, we describe the identification of a novel barrier, located in the vascular bed of tendons, which we term the blood-tendon barrier (BTB. By using immunohistochemistry, transmission electron microscopy, and tracer studies we demonstrate the presence of a functional endothelial barrier within tendons restricting the passage of large blood-borne molecules into the surrounding tendon tissue. We further provide in vitro evidence that the BTB potentially contributes to the creation of a distinct internal tissue environment impacting upon the proliferation and differentiation of tendon-resident cells, effects which might be fundamental for the onset of tendon pathologies.

  19. p38 MAPK signaling in postnatal tendon growth and remodeling.

    Directory of Open Access Journals (Sweden)

    Andrew J Schwartz

    Full Text Available Tendon is a dynamic tissue whose structure and function is influenced by mechanical loading, but little is known about the fundamental mechanisms that regulate tendon growth and remodeling in vivo. Data from cultured tendon fibroblasts indicated that the p38 MAPK pathway plays an important role in tendon fibroblast proliferation and collagen synthesis in vitro. To gain greater insight into the mechanisms of tendon growth, and explore the role of p38 MAPK signaling in this process, we tested the hypotheses that inducing plantaris tendon growth through the ablation of the synergist Achilles tendon would result in rapid expansion of a neotendon matrix surrounding the original tendon, and that treatment with the p38 MAPK inhibitor SB203580 would prevent this growth. Rats were treated with vehicle or SB203580, and subjected to synergist ablation by bilateral tenectomy of the Achilles tendon. Changes in histological and biochemical properties of plantaris tendons were analyzed 3, 7, or 28 days after overload, and comparisons were made to non-overloaded animals. By 28 days after overload, tendon mass had increased by 30% compared to non-overloaded samples, and cross-sectional area (CSA increased by around 50%, with most of the change occurring in the neotendon. The expansion in CSA initially occurred through the synthesis of a hyaluronic acid rich matrix that was progressively replaced with mature collagen. Pericytes were present in areas of active tendon growth, but never in the original tendon ECM. Inhibition of p38 MAPK resulted in a profound decrease in IL6 expression, and had a modest effect on the expression of other ECM and cell proliferation genes, but had a negligible impact on overall tendon growth. The combined results from this study provided novel insights into tendon mechanobiology, and suggest that p38 MAPK signaling does not appear to be necessary for tendon growth in vivo.

  20. Does the Morphology of the Forelimb Flexor Muscles Differ Between Lizards Using Different Habitats?

    Science.gov (United States)

    Lowie, Aurélien; Herrel, Anthony; Abdala, Virginia; Manzano, Adriana S; Fabre, Anne-Claire

    2018-03-01

    Lizards are an interesting group to study how habitat use impacts the morphology of the forelimb because they occupy a great diversity of ecological niches. In this study, we specifically investigated whether habitat use impacts the morphology of the forelimb flexor muscles in lizards. To do so, we performed dissections and quantified the physiological cross sectional area (PCSA), the fiber length, and the mass of four flexor muscles in 21 different species of lizards. Our results show that only the PCSA of the m. flexor carpi radialis is different among lizards with different ecologies (arboreal versus non-arboreal). This difference disappeared, however, when taking phylogeny into account. Arboreal species have a higher m. flexor carpi radialis cross sectional area likely allowing them to flex the wrist more forcefully which may allow them climb and hold on to branches better. In contrast, other muscles are not different between arboreal and non-arboreal species. Further studies focusing on additional anatomical features of the lizard forelimb as well as studies documenting how lizards use the arboreal niche are needed to fully understand how an arboreal life style may constrain limb morphology in lizards. Anat Rec, 301:424-433, 2018. © 2018 Wiley Periodicals, Inc. © 2018 Wiley Periodicals, Inc.

  1. Glutaraldehyde Cross-Linking of TendonMechanical Effects at the Level of the Tendon Fascicle and Fibril

    DEFF Research Database (Denmark)

    Hansen, P.; Svensson, R.B.; Aagaard, P.

    2009-01-01

    were examined by atomic force microscopy. Peak forces increased from 1379 to 2622 pN while an extended Hertz fit of force-indentation data showed a 24 fold increase in Young's modulus on indentation. The effect of glutaraldehyde cross-linking on the tensile properties of a single collagen fibril......Conclusive insight into the microscopic principles that govern the strength of tendon and related connective tissues is lacking and the importance of collagen cross-linking has not been firmly established. The combined application of whole-tissue mechanical testing and atomic force spectroscopy...... allowed for a detailed characterization of the effect of cross-linking in rat-tail tendon. The cross-link inducing agent glutaraldehyde augmented the tensile strength of tendon fascicles. Stress at failure increased from 8 MPa to 39 MPa. The mechanical effects of glutaraldehyde at the tendon fibril level...

  2. Flexion synergy overshadows flexor spasticity during reaching in chronic moderate to severe hemiparetic stroke.

    Science.gov (United States)

    Ellis, Michael D; Schut, Ingrid; Dewald, Julius P A

    2017-07-01

    Pharmaceutical intervention targets arm flexor spasticity with an often-unsuccessful goal of improving function. Flexion synergy is a related motor impairment that may be inadvertently neglected. Here, flexor spasticity and flexion synergy are disentangled to determine their contributions to reaching dysfunction. Twenty-six individuals participated. A robotic device systematically modulated shoulder abduction loading during ballistic reaching. Elbow muscle electromyography data were partitioned into windows delineated by elbow joint velocity allowing for the separation of synergy- and spasticity-related activation. Reaching velocity decreased with abduction loading (psynergy increased with abduction loading (psynergy is the predominant contributor to reaching dysfunction while flexor spasticity appears only relevant during unnaturally occurring passively supported movement. Interventions targeting flexion synergy should be leveraged in future stroke recovery trials. Copyright © 2017 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.

  3. Pathophysiology of overuse tendon injury

    International Nuclear Information System (INIS)

    Kannus, P.; Paavola, M.; Paakkala, T.; Parkkari, J.; Jaervinen, T.; Jaervinen, M.

    2002-01-01

    Overuse tendon injury is one of the most common injuries in sports.The etiology as well as the pathophysilogical mechanisms leading to tendinopathy are of crucial medical importance.At the moment intrinsic and extrinsic factors are assumed as mechanisms of overuse tendon injury. Except for the acute, extrinsic trauma, the chronic overuse tendon injury is a multifactorial process. There are many other factors, such as local hypoxia, less of nutrition, impaired metabolism and local inflammatory that may also contribute to the development of tissue damage.The exact interaction of these factors cannot be explained entirely at the moment.Further studies will be necessary in order to get more information. (orig.) [de

  4. Simultaneous bilateral patellar tendon rupture

    Directory of Open Access Journals (Sweden)

    Diogo Lino Moura

    Full Text Available ABSTRACT Bilateral patellar tendon rupture is a rare entity, often associated with systemic diseases and patellar tendinopathy. The authors report a rare case of a 34-year-old man with simultaneous bilateral rupture of the patellar tendon caused by minor trauma. The patient is a retired basketball player with no past complaints of chronic knee pain and a history of steroid use. Surgical management consisted in primary end-to-end tendon repair protected temporarily with cerclage wiring, followed by a short immobilization period and intensive rehabilitation program. Five months after surgery, the patient was able to fully participate in sport activities.

  5. Rotator cuff tendon connections with the rotator cable.

    Science.gov (United States)

    Rahu, Madis; Kolts, Ivo; Põldoja, Elle; Kask, Kristo

    2017-07-01

    The literature currently contains no descriptions of the rotator cuff tendons, which also describes in relation to the presence and characteristics of the rotator cable (anatomically known as the ligamentum semicirculare humeri). The aim of the current study was to elucidate the detailed anatomy of the rotator cuff tendons in association with the rotator cable. Anatomic dissection was performed on 21 fresh-frozen shoulder specimens with an average age of 68 years. The rotator cuff tendons were dissected from each other and from the glenohumeral joint capsule, and the superior glenohumeral, coracohumeral, coracoglenoidal and semicircular (rotator cable) ligaments were dissected. Dissection was performed layer by layer and from the bursal side to the joint. All ligaments and tendons were dissected in fine detail. The rotator cable was found in all specimens. It was tightly connected to the supraspinatus (SSP) tendon, which was partly covered by the infraspinatus (ISP) tendon. The posterior insertion area of the rotator cable was located in the region between the middle and inferior facets of the greater tubercle of the humerus insertion areas for the teres minor (TM), and ISP tendons were also present and fibres from the SSP extended through the rotator cable to those areas. The connection between the rotator cable and rotator cuff tendons is tight and confirms the suspension bridge theory for rotator cuff tears in most areas between the SSP tendons and rotator cable. In its posterior insertion area, the rotator cable is a connecting structure between the TM, ISP and SSP tendons. These findings might explain why some patients with relatively large rotator cuff tears can maintain seamless shoulder function.

  6. Supraspinatus tendon tears: comparison of US and MR arthrography with surgical correlation

    International Nuclear Information System (INIS)

    Ferrari, Francesco S.; Governi, Simone; Burresi, Francesca; Vigni, Francesco; Stefani, Paolo

    2002-01-01

    The aim of this study was to compare the diagnostic reliability of US with MR arthrography in diagnosing supraspinatus tendon tears. Surgical findings were used as the gold standard in detecting tears. A total of 44 patients were assessed with transverse and longitudinal US scans with respect to the long axis of the rotator cuff tendons and then examined with MR arthrography. This technique involved free-hand injection of contrast medium into the shoulder joint. At surgery 20 incomplete and 24 complete tears were observed. Ultrasound offered good results for the large tears, but its sensitivity decreased proportionally with the size of the tears. Magnetic resonance arthrography correctly diagnosed 43 tears, whereas only one false-negative diagnosis of tendinosis was made for a partial tear on the bursal side. Since it improves the diagnosis of small tears, MR arthrography must be performed on all patients for whom surgical repair is necessary in order to restore normal functions. (orig.)

  7. Supraspinatus tendon tears: comparison of US and MR arthrography with surgical correlation

    Energy Technology Data Exchange (ETDEWEB)

    Ferrari, Francesco S.; Governi, Simone; Burresi, Francesca; Vigni, Francesco; Stefani, Paolo [Department of Radiologic and Orthopaedic-Rehabilitative Sciences, University Hospital Siena (Italy)

    2002-05-01

    The aim of this study was to compare the diagnostic reliability of US with MR arthrography in diagnosing supraspinatus tendon tears. Surgical findings were used as the gold standard in detecting tears. A total of 44 patients were assessed with transverse and longitudinal US scans with respect to the long axis of the rotator cuff tendons and then examined with MR arthrography. This technique involved free-hand injection of contrast medium into the shoulder joint. At surgery 20 incomplete and 24 complete tears were observed. Ultrasound offered good results for the large tears, but its sensitivity decreased proportionally with the size of the tears. Magnetic resonance arthrography correctly diagnosed 43 tears, whereas only one false-negative diagnosis of tendinosis was made for a partial tear on the bursal side. Since it improves the diagnosis of small tears, MR arthrography must be performed on all patients for whom surgical repair is necessary in order to restore normal functions. (orig.)

  8. [Algorithms for treatment of complex hand injuries].

    Science.gov (United States)

    Pillukat, T; Prommersberger, K-J

    2011-07-01

    The primary treatment strongly influences the course and prognosis of hand injuries. Complex injuries which compromise functional recovery are especially challenging. Despite an apparently unlimited number of injury patterns it is possible to develop strategies which facilitate a standardized approach to operative treatment. In this situation algorithms can be important guidelines for a rational approach. The following algorithms have been proven in the treatment of complex injuries of the hand by our own experience. They were modified according to the current literature and refer to prehospital care, emergency room management, basic strategy in general and reconstruction of bone and joints, vessels, nerves, tendons and soft tissue coverage in detail. Algorithms facilitate the treatment of severe hand injuries. Applying simple yes/no decisions complex injury patterns are split into distinct partial problems which can be managed step by step.

  9. Uncovering the cellular and molecular changes in tendon stem/progenitor cells attributed to tendon aging and degeneration.

    Science.gov (United States)

    Kohler, Julia; Popov, Cvetan; Klotz, Barbara; Alberton, Paolo; Prall, Wolf Christian; Haasters, Florian; Müller-Deubert, Sigrid; Ebert, Regina; Klein-Hitpass, Ludger; Jakob, Franz; Schieker, Matthias; Docheva, Denitsa

    2013-12-01

    Although the link between altered stem cell properties and tissue aging has been recognized, the molecular and cellular processes of tendon aging have not been elucidated. As tendons contain stem/progenitor cells (TSPC), we investigated whether the molecular and cellular attributes of TSPC alter during tendon aging and degeneration. Comparing TSPC derived from young/healthy (Y-TSPC) and aged/degenerated human Achilles tendon biopsies (A-TSPC), we observed that A-TSPC exhibit a profound self-renewal and clonogenic deficits, while their multipotency was still retained. Senescence analysis showed a premature entry into senescence of the A-TSPC, a finding accompanied by an upregulation of p16(INK4A). To identify age-related molecular factors, we performed microarray and gene ontology analyses. These analyses revealed an intriguing transcriptomal shift in A-TSPC, where the most differentially expressed probesets encode for genes regulating cell adhesion, migration, and actin cytoskeleton. Time-lapse analysis showed that A-TSPC exhibit decelerated motion and delayed wound closure concomitant to a higher actin stress fiber content and a slower turnover of actin filaments. Lastly, based on the expression analyses of microarray candidates, we suggest that dysregulated cell-matrix interactions and the ROCK kinase pathway might be key players in TSPC aging. Taken together, we propose that during tendon aging and degeneration, the TSPC pool is becoming exhausted in terms of size and functional fitness. Thus, our study provides the first fundamental basis for further exploration into the molecular mechanisms behind tendon aging and degeneration as well as for the selection of novel tendon-specific therapeutical targets. © 2013 The Authors. Aging Cell published by the Anatomical Society and John Wiley & Sons Ltd.

  10. Role of biomechanics in the understanding of normal, injured, and healing ligaments and tendons

    Directory of Open Access Journals (Sweden)

    Jung Ho-Joong

    2009-05-01

    Full Text Available Abstract Ligaments and tendons are soft connective tissues which serve essential roles for biomechanical function of the musculoskeletal system by stabilizing and guiding the motion of diarthrodial joints. Nevertheless, these tissues are frequently injured due to repetition and overuse as well as quick cutting motions that involve acceleration and deceleration. These injuries often upset this balance between mobility and stability of the joint which causes damage to other soft tissues manifested as pain and other morbidity, such as osteoarthritis. The healing of ligament and tendon injuries varies from tissue to tissue. Tendinopathies are ubiquitous and can take up to 12 months for the pain to subside before one could return to normal activity. A ruptured medial collateral ligament (MCL can generally heal spontaneously; however, its remodeling process takes years and its biomechanical properties remain inferior when compared to the normal MCL. It is also known that a midsubstance anterior cruciate ligament (ACL tear has limited healing capability, and reconstruction by soft tissue grafts has been regularly performed to regain knee function. However, long term follow-up studies have revealed that 20–25% of patients experience unsatisfactory results. Thus, a better understanding of the function of ligaments and tendons, together with knowledge on their healing potential, may help investigators to develop novel strategies to accelerate and improve the healing process of ligaments and tendons. With thousands of new papers published in the last ten years that involve biomechanics of ligaments and tendons, there is an increasing appreciation of this subject area. Such attention has positively impacted clinical practice. On the other hand, biomechanical data are complex in nature, and there is a danger of misinterpreting them. Thus, in these review, we will provide the readers with a brief overview of ligaments and tendons and refer them to

  11. Role of biomechanics in the understanding of normal, injured, and healing ligaments and tendons

    Science.gov (United States)

    Jung, Ho-Joong; Fisher, Matthew B; Woo, Savio L-Y

    2009-01-01

    Ligaments and tendons are soft connective tissues which serve essential roles for biomechanical function of the musculoskeletal system by stabilizing and guiding the motion of diarthrodial joints. Nevertheless, these tissues are frequently injured due to repetition and overuse as well as quick cutting motions that involve acceleration and deceleration. These injuries often upset this balance between mobility and stability of the joint which causes damage to other soft tissues manifested as pain and other morbidity, such as osteoarthritis. The healing of ligament and tendon injuries varies from tissue to tissue. Tendinopathies are ubiquitous and can take up to 12 months for the pain to subside before one could return to normal activity. A ruptured medial collateral ligament (MCL) can generally heal spontaneously; however, its remodeling process takes years and its biomechanical properties remain inferior when compared to the normal MCL. It is also known that a midsubstance anterior cruciate ligament (ACL) tear has limited healing capability, and reconstruction by soft tissue grafts has been regularly performed to regain knee function. However, long term follow-up studies have revealed that 20–25% of patients experience unsatisfactory results. Thus, a better understanding of the function of ligaments and tendons, together with knowledge on their healing potential, may help investigators to develop novel strategies to accelerate and improve the healing process of ligaments and tendons. With thousands of new papers published in the last ten years that involve biomechanics of ligaments and tendons, there is an increasing appreciation of this subject area. Such attention has positively impacted clinical practice. On the other hand, biomechanical data are complex in nature, and there is a danger of misinterpreting them. Thus, in these review, we will provide the readers with a brief overview of ligaments and tendons and refer them to appropriate methodologies used to

  12. Variation in the insertion of the palmaris longus tendon

    Science.gov (United States)

    Sunil, Vinutha; Rajanna, Shubha; Gitanjali; Kadaba, Jayanthi

    2015-01-01

    The palmaris longus is harvested as a tendon graft in various surgical procedures. We herein report the variations in the insertion of the palmaris longus tendon. During a routine dissection, a rare variation in the insertion of the palmaris longus tendon was observed. In the left forearm, the palmaris longus tendon bifurcated, while in the right forearm, the palmaris longus tendon trifurcated, giving rise to an accessory muscle, which passed superficial to the ulnar artery and ulnar nerve. The accessory muscle was supplied by a deep branch of the ulnar nerve, and the ulnar artery was observed to be tortuous. During reconstructive surgeries, surgeons should bear in mind the accessory muscle. Also, since the palmaris longus muscle provides a very useful graft in tendon surgery, every surgeon should be aware of the variations in the insertion of the palmaris longus tendon. PMID:25640108

  13. Measurement of stress strain and vibrational properties of tendons

    Science.gov (United States)

    Revel, Gian Marco; Scalise, Alessandro; Scalise, Lorenzo

    2003-08-01

    The authors present a new non-intrusive experimental procedure based on laser techniques for the measurement of mechanical properties of tendons. The procedure is based on the measurement of the first resonance frequency of the tendon by laser Doppler vibrometry during in vitro tensile experiments, with the final aim of establishing a measurement procedure to perform the mechanical characterization of tendons by extracting parameters such as the resonance frequency, also achievable during in vivo investigation. The experimental procedure is reported, taking into account the need to simulate the physiological conditions of the Achilles tendon, and the measurement technique used for the non-invasive determination of tendon cross-sectional area during tensile vibration tests at different load levels is described. The test procedure is based on a tensile machine, which measures longitudinal tendons undergoing controlled load conditions. Cross-sectional area is measured using a new non-contact procedure for the measurement of tendon perimeter (repeatability of 99% and accuracy of 2%). For each loading condition, vibration resonance frequency and damping, cross-sectional area and tensile force are measured, allowing thus a mechanical characterization of the tendon. Tendon stress-strain curves are reported. Stress-strain curves have been correlated to the first vibration resonance frequency and damping of the tendon measured using a single-point laser Doppler vibrometer. Moreover, experimental results have been compared with a theoretical model of a vibrating cord showing discrepancies. In vitro tests are reported, demonstrating the validity of the method for the comparison of different aged rabbit tendons.

  14. Muscle function and fatigability of trunk flexors in males and females.

    Science.gov (United States)

    Deering, Rita E; Senefeld, Jonathon W; Pashibin, Tatyana; Neumann, Donald A; Hunter, Sandra K

    2017-01-01

    Optimal function of the abdominal muscles is necessary for several life functions including lifting and carrying tasks. Sex differences in strength and fatigability are established for many limb muscles and back extensor muscles, but it is unknown if sex differences exist for the abdominal muscles despite their functional importance. Eighteen females (24.3 ± 4.8 years) and 15 males (24.1 ± 6.6 years) performed (1) isometric trunk flexion maximal voluntary contractions (MVCs) in a range of trunk positions to establish a torque-angle curve and (2) submaximal (50% MVC), intermittent isometric contraction (6 s on, 4 s off) until task failure to determine fatigability of the trunk flexor muscles. Dual X-ray absorptiometry quantified body fat and lean mass. Physical activity levels were quantified with a questionnaire. Torque-angle curves, electromyography (EMG), MVC torque, and torque steadiness were compared with repeated measures ANOVA with sex as a between-subjects factor. For the torque-angle curve, MVC torque was reduced as the trunk angle increased toward flexion ( p    0.05). Time-to-task failure for the submaximal fatigability task in upright sitting was similar between males and females (12.4 ± 7 vs 10.5 ± 6 min). Time-to-task failure was positively associated with strength ( r  = 0.473, p  = 0.005) and self-reported physical activity ( r  = 0.456, p  = 0.030). Lean mass in the trunk was positively associated with trunk flexor strength ( r  = 0.378, p  = 0.011) and self-reported physical activity ( r  = 0.486, p  = 0.007). Finally, torque steadiness [coefficient of variation of torque (CV)] during submaximal isometric contractions decreased with contraction intensity and was similar for males and females across all intensities. Unlike many limb muscle groups, males and females had similar fatigability and torque steadiness of the trunk flexor muscles during isometric contractions. Stronger individuals

  15. Large strengthening effect of a hip-flexor training programme

    DEFF Research Database (Denmark)

    Thorborg, Kristian; Bandholm, Thomas Quaade; Zebis, Mette

    2016-01-01

    PURPOSE: To investigate the effect on hip-flexion strength of a 6-week hip-flexor training programme using elastic bands as resistance. We hypothesized that the training group, compared to a control group, would increase their hip-flexion strength more. METHODS: Thirty-three healthy subjects (45 ...

  16. Stem Cell Applications in Tendon Disorders: A Clinical Perspective

    Directory of Open Access Journals (Sweden)

    Mark Young

    2012-01-01

    Full Text Available Tendon injuries are a common cause of morbidity and a significant health burden on society. Tendons are structural tissues connecting muscle to bone and are prone to tearing and tendinopathy, an overuse or degenerative condition that is characterized by failed healing and cellular depletion. Current treatments, for tendon tear are conservative, surgical repair or surgical scaffold reconstruction. Tendinopathy is treated by exercises, injection therapies, shock wave treatments or surgical tendon debridement. However, tendons usually heal with fibrosis and scar tissue, which has suboptimal tensile strength and is prone to reinjury, resulting in lifestyle changes with activity restriction. Preclinical studies show that cell therapies have the potential to regenerate rather than repair tendon tissue, a process termed tenogenesis. A number of different cell lines, with varying degrees of differentiation, have being evaluated including stem cells, tendon derived cells and dermal fibroblasts. Even though cellular therapies offer some potential in treating tendon disorders, there have been few published clinical trials to determine the ideal cell source, the number of cells to administer, or the optimal bioscaffold for clinical use.

  17. Identified ankle extensor and flexor motoneurons display different firing profiles in the neonatal rat

    DEFF Research Database (Denmark)

    Cotel, Florence; Antri, Myriam; Barthe, Jean-Yves

    2009-01-01

    population of flexor motoneurons solely exhibited the type II profile, characterized by a frequency-current (F-I) relationship with a clockwise hysteresis. In contrast, in addition to this type II profile, the other three profiles of repetitive firing (type I, III and IV) were observed in extensor...... postnatal development, a significant part of the population of extensor motoneurons, but not flexors, are able to produce self-sustained discharges known to involve the activation of persistent inward currents....

  18. Percutaneous flexor tenotomy for preventing and treating toe ulcers in people with diabetes mellitus

    DEFF Research Database (Denmark)

    Rasmussen, Anne; Bjerre-Christensen, Ulla; Almdal, Thomas Peter

    2013-01-01

    The purpose was to examine the effectiveness of flexor tenotomy in a modified technique to prevent and heal neuropathic and neuroischaemic pressure ulcers on the tip of the toe in claw- or hammer-toe deformities in people with diabetes.......The purpose was to examine the effectiveness of flexor tenotomy in a modified technique to prevent and heal neuropathic and neuroischaemic pressure ulcers on the tip of the toe in claw- or hammer-toe deformities in people with diabetes....

  19. Region-specific mechanical properties of the human patella tendon

    DEFF Research Database (Denmark)

    Haraldsson, B T; Aagaard, P; Krogsgaard, M

    2004-01-01

    The present study investigated the mechanical properties of tendon fascicles from the anterior and posterior human patellar tendon. Collagen fascicles from the anterior and posterior human patellar tendon in healthy young men (mean +/- SD, 29.0 +/- 4.6 yr, n = 6) were tested in a mechanical rig...... portion of the tendon, indicating region-specific material properties....

  20. Repair of the torn distal biceps tendon by endobutton fixation

    Directory of Open Access Journals (Sweden)

    Ravi K Gupta

    2012-01-01

    Full Text Available Background: A number of techniques have been described to reattach the torn distal biceps tendon to the bicipital tuberosity. We report a retrospective analysis of single incision technique using an endobutton fixation in sports persons. Materials and Methods: The present series include nine torn distal biceps tendons in eight patients, fixed anatomically to the radial tuberosity with an endobutton by using a single incision surgical technique; seven patients had suffered the injuries during contact sports. The passage of the endobutton was facilitated by using a blunt tipped pin in order to avoid injury to the posterior interosseous nerve. The patients were evaluated by Disabilities of the Arm, Shoulder and Hand (DASH score and Mayo elbow score. Results: The average age of the patients was 27.35 years (range 21-42 years. Average follow-up was 41.5 months (range 24-102 months. The final average flexion extension arc was 0°-143°, while the average pronation and supination angles were 77° (range 70°-82° and 81° (range 78°-85°, respectively at the last followup. All the patients had a Disabilities of the Arm, Shoulder and Hand (DASH score of 0 and a Mayo elbow score of 100 each. All the seven active sports persons were able to get back to their respective game. There was no nerve injury or any other complication. Conclusions: The surgical procedure used by us is a simple, safe and reproducible technique giving minimal morbidity and better cosmetic results.

  1. Arthroscopic Removal and Rotator Cuff Repair Without Acromioplasty for the Treatment of Symptomatic Calcifying Tendinitis of the Supraspinatus Tendon.

    Science.gov (United States)

    Ranalletta, Maximiliano; Rossi, Luciano Andrés; Bongiovanni, Santiago Luis; Tanoira, Ignacio; Piuzzi, Nicolas; Maignon, Gastón

    2015-04-01

    Calcified rotator cuff tendinitis is a common cause of chronic shoulder pain that leads to significant pain and functional limitations. Although most patients respond well to conservative treatment, some eventually require surgical treatment. To evaluate the clinical outcome with arthroscopic removal of calcific deposit and rotator cuff repair without acromioplasty for the treatment of calcific tendinitis of the supraspinatus tendon. Case series; Level of evidence, 4. This study retrospectively evaluated 30 consecutive patients with a mean age of 49.2 years. The mean follow-up was 35 months (range, 24-88 months). Pre- and postoperative functional assessment was performed using the Constant score, University of California Los Angeles (UCLA) score, and Quick Disabilities of the Arm, Shoulder, and Hand (DASH). Pain was assessed by visual analog scale (VAS). Radiographs and magnetic resonance imaging (MRI) were performed to evaluate the recurrence of calcifications and the indemnity of the supraspinatus tendon repair. Significant improvement was obtained for pain (mean VAS, 8.7 before surgery to 0.8 after; P rotator cuff repair without acromioplasty can lead to good results in patients with symptomatic calcifying tendonitis of the supraspinatus tendon.

  2. Tendon Interposition and Ligament Reconstruction with ECRL Tendon in the Late Stages of Kienböck’s Disease: A Cadaver Study

    Directory of Open Access Journals (Sweden)

    Nazım Karalezli

    2013-01-01

    Full Text Available Background. The optimal surgical treatment for Kienböck’s disease with stages IIIB and IV remains controversial. A cadaver study was carried out to evaluate the use of coiled extensor carpi radialis longus tendon for tendon interposition and a strip obtained from the same tendon for ligament reconstruction in the late stages of Kienböck’s disease. Methods. Coiled extensor carpi radialis longus tendon was used to fill the cavity of the excised lunate, and a strip obtained from this tendon was sutured onto itself after passing through the scaphoid and the triquetrum acting as a ligament to preserve proximal row integrity. Biomechanical tests were carried out in order to evaluate this new ligamentous reconstruction. Results. It was biomechanically confirmed that the procedure was effective against axial compression and distributed the upcoming mechanical stress to the distal row. Conclusion. Extensor carpi radialis longus tendon has not been used for tendon interposition and ligament reconstruction in the treatment of this disease before. In view of the biomechanical data, the procedure seems to be effective for the stabilization of scaphoid and carpal bones.

  3. Temporal growth factor release from platelet-rich plasma, trehalose lyophilized platelets, and bone marrow aspirate and their effect on tendon and ligament gene expression.

    Science.gov (United States)

    McCarrel, Taralyn; Fortier, Lisa

    2009-08-01

    Platelet-rich plasma (PRP) has generated substantial interest for tendon and ligament regeneration because of the high concentrations of growth factors in platelet alpha-granules. This study compared the temporal release of growth factors from bone marrow aspirate (BMA), PRP, and lyophilized platelet product (PP), and measured their effects on tendon and ligament gene expression. Blood and BMA were collected and processed to yield PRP and plasma. Flexor digitorum superficialis tendon (FDS) and suspensory ligament (SL) explants were cultured in 10% plasma in DMEM (control), BMA, PRP, or PP. TGF-beta1 and PDGF-BB concentrations were determined at 0, 24, and 96 h of culture using ELISA. Quantitative RT-PCR for collagen types I and III (COL1A1, COL3A1), cartilage oligomeric matrix protein (COMP), decorin, and matrix metalloproteinases-3 and 13 (MMP-3, MMP-13) was performed. TGF-beta1 and PDGF-BB concentrations were highest in PRP and PP. Growth factor quantity was unchanged in BMA, increased in PRP, and decreased in PP over 4 days. TGF-beta1 and platelet concentrations were positively correlated. Lyophilized PP and PRP resulted in increased COL1A1:COL3A1 ratio, increased COMP, and decreased MMP-13 expression. BMA resulted in decreased COMP and increased MMP-3 and MMP-13 gene expression. Platelet concentration was positively correlated with COL1A1, ratio of COL1A1:COL3A1, and COMP, and negatively correlated with COL3A1, MMP-13, and MMP-3. White blood cell concentration was positively correlated with COL3A1, MMP3, and MMP13, and negatively correlated with a ratio of COL1A1:COL3A1, COMP, and decorin. These findings support further in vivo investigation of PRP and PP for treatment of tendonitis and desmitis. Copyright 2009 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  4. Nanoparticles for tendon healing and regeneration: literature review.

    Directory of Open Access Journals (Sweden)

    Paolo Domenico Parchi

    2016-08-01

    Full Text Available Tendon injuries are commonly met in the emergency department. Unfortunately, tendon tissue has limited regeneration potential and usually the consequent formation of scar tissue causes inferior mechanical properties Nanoparticles could be used in different way to improve tendon healing and regeneration, ranging from scaffolds manufacturing (increasing the strength and endurance or anti-adhesions, anti-microbial and anti-inflammatory properties to gene therapy. This paper aims to summarize the most relevant studies showing the potential application of nanoparticles for tendon tissue regeneration

  5. Tendon allograft sterilized by peracetic acid/ethanol combined with gamma irradiation.

    Science.gov (United States)

    Zhou, Mo; Zhang, Naili; Liu, Xiaoming; Li, Youchen; Zhang, Yumin; Wang, Xusheng; Li, Baoming; Li, Baoxing

    2014-07-01

    Research and clinical applications have demonstrated that the effects of tendon allografts are comparable to those of autografts when reconstructing injured tendons or ligaments, but allograft safety remains problematic. Sterilisation could eliminate or decrease the possibility of disease transmission, but current methods seldom achieve satisfactory sterilisation without affecting the mechanical properties of the tendon. Peracetic acid-ethanol in combination with low-dose gamma irradiation (PE-R) would inactivate potential deleterious microorganisms without affecting mechanical and biocompatible properties of tendon allograft. Controlled laboratory design. HIV, PPV, PRV and BVDV inactivation was evaluated. After verifying viral inactivation, the treated tendon allografts were characterised by optical microscopy, scanning electron microscopy and tensile testing, and the cytocompatibility was assessed with an MTT assay and by subcutaneous implantation. Effective and efficient inactivation of HIV, PPV, PRV and BVDV was observed. Histological structure and ultrastructure were unchanged in the treated tendon allograft, which also exhibited comparable biomechanical properties and good biocompatibility. The preliminary results confirmed our hypothesis and demonstrated that the PE-R tendon allograft has significant potential as an alternative to ligament/tendon reconstruction. Tendon allografts have been extensively used in ligament reconstruction and tendon repair. However, current sterilisation methods have various shortcomings, so PE-R has been proposed. This study suggests that PE-R tendon allograft has great potential as an alternative for ligament/tendon reconstruction. Sterilisation has been a great concern for tendon allografts. However, most sterilisation methods cannot inactivate viruses and bacteria without impairing the mechanical properties of the tendon allograft. Peracetic acid/ethanol with gamma irradiation can effectively inactivate viruses and bacteria

  6. Mechanical comparative analysis of three different types of sutures in different dimensions tendons: experimental study Análise mecânica comparativa de três tipos de sutura entre tendões de dimensões diferentes: estudo experimental

    Directory of Open Access Journals (Sweden)

    Trajano Sardenberg

    2002-09-01

    Full Text Available The aim of this experimental investigation was study of mechanical profile of three kinds of suture, between tendons with different dimensions. Were utilized 21 mongrel dogs ( 11males, 10 females of wich were obtained the tendon comum flexor and tendon tibial cranial of both pelvic limbs. After the dissection of the tendons, suture was done, seven animal per group. The tendons utilized allways were from the right limb and from the left limb side utilized as control. After the suture, we performed axial traction tests, rate level of 30mm /min, using special jaws. After the test the machine's program informed the values of ultimate load, elongation and strain, and load elongation diagram. The results were submite to statistical study, that showed no difference between the technics utilized. The values of suture groups were smaller than the control, for ultimate load, and higher for elongation and strain.O objetivo da presente investigação experimental foi avaliar o perfil mecânico de três tipos de técnicas de sutura entre tendões de dimensões diferentes. Foram utilizados 21 cães sem raça definida (11machos/10 fêmeas, dos quais foram obtidos os tendões flexor comum dos dedos - t.c. (maior dimensão e tibial cranial - t.cr. (menor dimensão, de ambos os membros pélvicos. Logo após a obtenção das peças foi realizada sutura, segundo cada tipo de técnica, porém sempre com o mesmo número de pontos. Os tendões utilizados para sutura foram sempre do lado direito e o controle do lado esquerdo (t.cr.. Após a sutura, os corpos de prova foram fixados em garras especialmente desenvolvidas e submetidos a ensaio de tração axial à velocidade de 30mm/minuto. Após o ensaio o programa da máquina forneceu os valores da carga máxima ( na ruptura e deformação absoluta (mm e relativa (%, além do diagrama carga-deformação. Os resultados foram submetidos a estudo estatístico pela análise de medidas repetidas no nível de 5% de signific

  7. Reproducibility and clinical utility of tendon palpation to detect patellar tendinopathy in young basketball players. Victorian Institute of Sport tendon study group.

    Science.gov (United States)

    Cook, J L; Khan, K M; Kiss, Z S; Purdam, C R; Griffiths, L

    2001-02-01

    Palpation is an important clinical test for jumper's knee. To (a) test the reproducibility of palpation tenderness, (b) evaluate the sensitivity and specificity of palpation in subjects with clinical symptoms of jumper's knee, and (c) determine whether tenderness to palpation may serve as a useful screening test for patellar tendinopathy. The yardstick for diagnosis of patellar tendinopathy was ultrasonographic abnormality. In 326 junior symptomatic and asymptomatic athletes' tendons, palpation was performed by a single examiner before ultrasonographic examination by a certified ultrasound radiologist. In 58 tendons, palpation was performed twice to test reliability. Tenderness to palpation was scored on a scale from 0 to 3 where 0 represented no pain, and 1, 2, and 3 represented mild, moderate, and severe tenderness respectively. Patellar tendon palpation was a reliable examination for a single examiner (Pearson r = 0.82). In symptomatic tendons, the positive predictive value of palpation was 68%. As a screening examination in asymptomatic subjects, the positive predictive value of tendon palpation was 36-38%. Moderate and severe palpation tenderness were better predictors of ultrasonographic tendon pathology than absent or mild tenderness (ppatellar tendinopathy in a preparticipation examination. In symptomatic tendons, palpation is a moderately sensitive but not specific test. Mild tenderness in the patellar tendons in asymptomatic jumping athletes should be considered normal.

  8. Science to Practice: Quantitative US Elastography Can Be Used to Quantify Mechanical and Histologic Tendon Healing in a Rabbit Model of Achilles Tendon Transection.

    Science.gov (United States)

    Lee, Kenneth S; Martin, Jack; Thelen, Darryl

    2017-05-01

    Compression-based ultrasonographic (US) elastography is associated with time-dependent mechanical and histologic changes of the healing tendon in a transected rabbit model of the Achilles tendon. This finding will lead to continued development of quantitative US, which can be used to objectively assess a diseased or healing tendon. With advances in the method used, clinical translation of tendon elastography may enable clinicians to diagnose tendon damage and track healing, which should improve both treatment and outcome.

  9. Tendon injury and repair - A perspective on the basic mechanisms of tendon disease and future clinical therapy

    NARCIS (Netherlands)

    Snedeker, J.G.; Foolen, J.

    2017-01-01

    Tendon is an intricately organized connective tissue that efficiently transfers muscle force to the bony skeleton. Its structure, function, and physiology reflect the extreme, repetitive mechanical stresses that tendon tissues bear. These mechanical demands also lie beneath high clinical rates of

  10. MRI and gross anatomy of the iliopsoas tendon complex

    International Nuclear Information System (INIS)

    Polster, Joshua M.; Lee, Ho; Klika, Alison; Barsoum, Wael; Drake, Richard; Elgabaly, Mohamed

    2008-01-01

    The objective was to explain the anatomic basis of a longitudinal cleft of increased signal in the iliopsoas tendon seen on hip MR arthrograms. A prospective review of 20 MR hip arthrograms was performed using standard and fat-suppressed T1-weighted images to establish whether or not the cleft was composed of fatty tissue and to define the anatomy of the iliopsoas tendon complex. Three cadaver dissections of the hip region were then performed for anatomic correlation. Fourteen out of 20 MR hip arthrograms demonstrated a longitudinal cleft of increased T1 signal adjacent to the iliopsoas tendon, which suppressed on frequency selective fat-suppressed images, indicating fatty composition. Gross anatomic correlation demonstrated this fatty cleft to represent a fascial plane adjacent to the iliopsoas tendon, in one case separating the iliopsoas tendon medially from a thin intramuscular tendon within the lateral portion of the iliacus muscle. Also noted was a direct muscular insertion of the lateral portion of the iliacus muscle onto the anterior portion of the proximal femoral diaphysis in all 3 cadavers. The anatomy of the iliopsoas tendon complex is more complicated than typically illustrated and includes the iliopsoas tendon itself attaching to the lesser trochanter, the lateral portion of the iliacus muscle attaching directly upon the anterior portion of the proximal femoral diaphysis, and a thin intramuscular tendon within this lateral iliacus muscle that is separated from the iliopsoas tendon by a cleft of fatty fascia that accounts for the MRI findings of a cleft of increased T1 signal. (orig.)

  11. The change in deep cervical flexor activity after training is associated with the degree of pain reduction in patients with chronic neck pain.

    Science.gov (United States)

    Falla, Deborah; O'Leary, Shaun; Farina, Dario; Jull, Gwendolen

    2012-09-01

    Altered activation of the deep cervical flexors (longus colli and longus capitis) has been found in individuals with neck pain disorders but the response to training has been variable. Therefore, this study investigated the relationship between change in deep cervical flexor muscle activity and symptoms in response to specific training. Fourteen women with chronic neck pain undertook a 6-week program of specific training that consisted of a craniocervical flexion exercise performed twice per day (10 to 20 min) for the duration of the trial. The exercise targets the deep flexor muscles of the upper cervical region. At baseline and follow-up, measures were taken of neck pain intensity (visual analogue scale, 0 to 10), perceived disability (Neck Disability Index, 0 to 50) and electromyography (EMG) of the deep cervical flexors (by a nasopharyngeal electrode suctioned over the posterior oropharyngeal wall) during performance of craniocervical flexion. After training, the activation of the deep cervical flexors increased (Pcervical flexor EMG amplitude at baseline (R(2)=0.68; Ppain intensity, change in pain level with training, and change in EMG amplitude for the deep cervical flexors during craniocervical flexion (R(2)=0.34; Pcervical flexor muscles in women with chronic neck pain reduces pain and improves the activation of these muscles, especially in those with the least activation of their deep cervical flexors before training. This finding suggests that the selection of exercise based on a precise assessment of the patients' neuromuscular control and targeted exercise interventions based on this assessment are likely to be the most beneficial to patients with neck pain.

  12. Tarsal tunnel disease and talocalcaneal coalition: MRI features

    Energy Technology Data Exchange (ETDEWEB)

    FitzGerald Alaia, Erin; Rosenberg, Zehava Sadka; Bencardino, Jenny T.; Ciavarra, Gina A.; Petchprapa, Catherine N. [New York University Langone Medical Center, New York, NY (United States); Rossi, Ignacio [New York University Langone Medical Center, New York, NY (United States); Centro de Diagnostico Dr. Enrique Rossi, Buenos Aires (Argentina)

    2016-11-15

    To assess, utilizing MRI, tarsal tunnel disease in patients with talocalcaneal coalitions. To the best of our knowledge, this has only anecdotally been described before. Sixty-seven ankle MRIs with talocalcaneal coalition were retrospectively reviewed for disease of tendons and nerves of the tarsal tunnel. Interobserver variability in diagnosing tendon disease was performed in 30 of the 67 cases. Tarsal tunnel nerves were also evaluated in a control group of 20 consecutive ankle MRIs. Entrapment of the flexor hallucis longus tendon (FHL) by osseous excrescences was seen in 14 of 67 cases (21 %). Attenuation, split tearing, tenosynovitis, or tendinosis of the FHL was present in 26 cases (39 %). Attenuation or tenosynovitis was seen in the flexor digitorum longus tendon (FDL) in 18 cases (27 %). Tenosynovitis or split tearing of the posterior tibial tendon (PT) was present in nine cases (13 %). Interobserver variability ranged from 100 % to slight depending on the tendon and type of disease. Intense increased signal and caliber of the medial plantar nerve (MPN), indicative of neuritis, was seen in 6 of the 67 cases (9 %). Mildly increased T2 signal of the MPN was seen in 15 (22 %) and in 14 (70 %) of the control group. Talocalcaneal coalitions may be associated with tarsal tunnel soft tissue abnormalities affecting, in decreasing order, the FHL, FDL, and PT tendons, as well as the MPN. This information should be provided to the referring physician in order to guide treatment and improve post-surgical outcome. (orig.)

  13. Tarsal tunnel disease and talocalcaneal coalition: MRI features

    International Nuclear Information System (INIS)

    FitzGerald Alaia, Erin; Rosenberg, Zehava Sadka; Bencardino, Jenny T.; Ciavarra, Gina A.; Petchprapa, Catherine N.; Rossi, Ignacio

    2016-01-01

    To assess, utilizing MRI, tarsal tunnel disease in patients with talocalcaneal coalitions. To the best of our knowledge, this has only anecdotally been described before. Sixty-seven ankle MRIs with talocalcaneal coalition were retrospectively reviewed for disease of tendons and nerves of the tarsal tunnel. Interobserver variability in diagnosing tendon disease was performed in 30 of the 67 cases. Tarsal tunnel nerves were also evaluated in a control group of 20 consecutive ankle MRIs. Entrapment of the flexor hallucis longus tendon (FHL) by osseous excrescences was seen in 14 of 67 cases (21 %). Attenuation, split tearing, tenosynovitis, or tendinosis of the FHL was present in 26 cases (39 %). Attenuation or tenosynovitis was seen in the flexor digitorum longus tendon (FDL) in 18 cases (27 %). Tenosynovitis or split tearing of the posterior tibial tendon (PT) was present in nine cases (13 %). Interobserver variability ranged from 100 % to slight depending on the tendon and type of disease. Intense increased signal and caliber of the medial plantar nerve (MPN), indicative of neuritis, was seen in 6 of the 67 cases (9 %). Mildly increased T2 signal of the MPN was seen in 15 (22 %) and in 14 (70 %) of the control group. Talocalcaneal coalitions may be associated with tarsal tunnel soft tissue abnormalities affecting, in decreasing order, the FHL, FDL, and PT tendons, as well as the MPN. This information should be provided to the referring physician in order to guide treatment and improve post-surgical outcome. (orig.)

  14. Increasing platelet concentrations in leukocyte-reduced platelet-rich plasma decrease collagen gene synthesis in tendons.

    Science.gov (United States)

    Boswell, Stacie G; Schnabel, Lauren V; Mohammed, Hussni O; Sundman, Emily A; Minas, Tom; Fortier, Lisa A

    2014-01-01

    Platelet-rich plasma (PRP) is used for the treatment of tendinopathy. There are numerous PRP preparations, and the optimal combination of platelets and leukocytes is not known. Within leukocyte-reduced PRP (lrPRP), there is a plateau effect of platelet concentration, with increasing platelet concentrations being detrimental to extracellular matrix synthesis. Controlled laboratory study. Different formulations of lrPRP with respect to the platelet:leukocyte ratio were generated from venous blood of 8 horses. Explants of the superficial digital flexor tendon were cultured in lrPRP products for 96 hours. Platelet-derived growth factor-BB (PDGF-BB), tumor necrosis factor-α (TNF-α), transforming growth factor-β1 (TGF-β1), and interleukin-1β (IL-1β) concentrations were determined in the media by enzyme-linked immunosorbent assay. Gene expression in tendon tissue for collagen type I and III (COL1A1 and COL3A1, respectively), matrix metalloproteinase-3 and -13 (MMP-3 and MMP-13, respectively), cartilage oligomeric matrix protein (COMP), and IL-1β was determined. Data were divided into 3 groups of lrPRP based on the ratio of platelets:leukocytes and evaluated to determine the effect of platelet concentration. Complete blood counts verified leukocyte reduction and platelet enrichment in all PRP preparations. In the lrPRP preparation, the anabolic growth factors PDGF-BB and TGF-β1 were increased with increasing platelet concentrations, and the catabolic cytokine IL-1β was decreased with increasing platelet concentrations. Increasing the platelet concentration resulted in a significant reduction in COL1A1 and COL3A1 synthesis in tendons. Increasing the platelet concentration within lrPRP preparations results in the delivery of more anabolic growth factors and less proinflammatory cytokines, but the biological effect on tendons is diminished metabolism as indicated by a decrease in the synthesis of both COL1A1 and COL3A1. Together, this information suggests that

  15. The 'bridging sign', a MR finding for combined full-thickness tears of the subscapularis tendon and the supraspinatus tendon

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Jin Young [Dept. of Radiology, Saint Paul' s Hospital, The Catholic Univ. of Korea, Seoul (Korea, Republic of); Yoon, Young Cheol; Cha, Dong Ik [Dept. of Radiology, Samsung Medical Center, Sungkyunkwan Univ, School of Medicine, Seoul (Korea, Republic of)], e-mail: ycyoon@skku.edu; Yoo, Jae-Chul [Dept. of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan Univ. School of Medicine, Seoul (Korea, Republic of); Jung, Jee Young [Dept. of Radiology, School of Medicine, Chung-Ang Univ., Seoul (Korea, Republic of)

    2013-02-15

    Background: In daily practice, we discovered one of the secondary magnetic resonance (MR) findings of the subscapularis (SSC) tendon tear, the 'bridging sign', which has not been previously described. Purpose: To describe the 'bridging sign' on shoulder MR imaging and its radiological and clinical significance in patients with SSC tendon tear. Material and Methods: Twenty-nine patients who had undergone shoulder arthroscopy and had full-thickness tear of the subscapularis tendon were enrolled. The medical records of the 29 patients were retrospectively reviewed for the duration of shoulder pain, rotator cuff tears, and associated arthroscopic findings: biceps tendon abnormality and superior glenoid labral tear. Then, preoperative shoulder MR images were retrospectively reviewed for the presence or absence of the 'bridging sign' and associated MR findings: periarticular fluid and fatty atrophy of the supraspinatus and subscapularis muscles. The type of rotator cuff tear associated with the 'bridging sign' was assessed and the sensitivity, specificity, and accuracy of the 'bridging sign' for the diagnosis of a certain type of rotator cuff tear were calculated. Associated arthroscopic and MR findings and mean duration of the shoulder pain between the patients with and without the 'bridging sign' were compared. Results: The 'bridging sign' was seen in 17 of 29 patients and corresponded to a complex of the torn and superomedially retracted subscapularis tendon, coracohumeral ligament, and superior glenohumeral ligament, adhered to the anterior margin of the torn supraspinatus (SSP) tendon on arthroscopy. All patients with the 'bridging sign' had combined full-thickness tear (FTT) of the cranial 1/2 portion of the subscapularis tendon and anterior 1/2 portion of the SSP tendon. The sensitivity, specificity, and accuracy of the 'bridging sign' for the diagnosis of combined FTTs of

  16. Regional strain variations in the human patellar tendon.

    Science.gov (United States)

    Pearson, Stephen J; Ritchings, Tim; Mohamed, Azlan S A

    2014-07-01

    Characteristics of localized tendon strain in vivo are largely unknown. The present study examines local tendon strain between the deep, middle, and surface structures at the proximal and distal aspects of the patellar tendon during ramped isometric contractions. Male subjects (age 28.0 ± 6.3 yr) were examined for patellar tendon excursion (anterior, midsection, and posterior) during ramped isometric voluntary contractions using real-time B-mode ultrasonography and dynamometry. Regional tendon excursion measurements were compared using an automated pixel tracking method. Strain was determined from the tendon delta length normalized to initial/resting segment length. Strain increased from 10% to 100% of force for all regions. Significantly greater mean strain was seen for the anterior proximal region compared to the posterior and mid layer of the tendon (7.5% ± 1.1% vs 3.7% ± 0.5% vs 5.5% ± 1.0%; P < 0.05). Similarly, the distal posterior region showed greater mean strain compared to the mid and anterior regions (7.9% ± 0.6% vs 5.0% ± 0.6% vs 5.4% ± 0.6%; P < 0.05). Relative changes in strain differences from 50% to 100% of force for the proximal region were greatest for the anterior to midline regions (4.6% ± 0.6% and 5.6% ± 0.6%, respectively) and those for the distal region were also greatest for the anterior to midline regions (4.4% ± 0.2% and 5.3% ± 0.2%, respectively). The largest mean strain for the proximal region was at the anterior layer (7.5% ± 1.1%) and that for the distal tendon region was at the posterior layer (7.9% ± 0.9%). This study shows significant regional differences in strain during ramped isometric contractions for the patellar tendon. Lower proximal strains in the posterior tendon compared to the anterior region may be associated with the suggestion of "stress shielding" as an etiological factor in insertional tendinopathy.

  17. Torque Control of Underactuated Tendon-driven Robotic Fingers

    Science.gov (United States)

    Abdallah, Muhammad E. (Inventor); Ihrke, Chris A. (Inventor); Reiland, Matthew J. (Inventor); Wampler, Charles W. (Inventor); Diftler, Myron A. (Inventor); Platt, Robert (Inventor); Bridgwater, Lyndon (Inventor)

    2013-01-01

    A robotic system includes a robot having a total number of degrees of freedom (DOF) equal to at least n, an underactuated tendon-driven finger driven by n tendons and n DOF, the finger having at least two joints, being characterized by an asymmetrical joint radius in one embodiment. A controller is in communication with the robot, and controls actuation of the tendon-driven finger using force control. Operating the finger with force control on the tendons, rather than position control, eliminates the unconstrained slack-space that would have otherwise existed. The controller may utilize the asymmetrical joint radii to independently command joint torques. A method of controlling the finger includes commanding either independent or parameterized joint torques to the controller to actuate the fingers via force control on the tendons.

  18. DASH (disabilities of the arm, shoulder, and hand) evaluation of QOL for carpal tunnel syndrome

    International Nuclear Information System (INIS)

    Morita, Akimasa; Kawamoto, Masataka; Fujisawa, Kouzou; Tsujii, Masaya; Hirata, Hitoshi

    2006-01-01

    The questionnaire on the disabilities of the arm, shoulder, and hand is a region-specific, self-administered outcome instrument that is developed as a measure of self-rate upper extremity disability and symptoms. Last year, the Japanese version of disabilities of the arm, shoulder and hand (DASH) was cross-culturally adapted. The main purpose of this study is to analyze the relationship between DASH and clinical assessment (findings of MRI and electrodiagnostic parameters). The subjects comprised 41 patients (6 males and 35 females) with carpal tunnel syndrome (CTS), except for cases with other upper extremity disorders. These subjects prospectively completed DASH 1 (disability module), DASH 2 (symptom module), and DASH (disability and symptom module) before the release of the open carpal tunnel. The patients were divided into 3 groups based on the symptom duration (A: shorter than 3 months, B: 4-11 months, C: longer than 12 months). All patients were preoperatively assessed with regard to sensory conduction velocity (SCV) and compound muscle action potential (CMAP). In addition, all patients underwent MRI in order to evaluate the flexor tenosynovial swelling represented by palmar bowing of the flexor retinaculum (PBFR). The relationships were estimated using the Spearman rank score, unpaired t tests, and Bonferroni tests. DASH 2 scores indicated greater responsiveness than DASH 1, which reflected the character of CTS. DASH 1 scores were higher in patients who were affected in their dominant hand than in those whose nondominant hand was affected. The DASH scores decreased significantly in groups A and B, with the exception of C. However, DASH did not show any correlation either with the parameters, age, or MRI assessment. DASH can be used for the research of preoperative outcomes related to CTS. It also has the advantage of being useful in assessing and comparing the outcome for various other hand disorders. (author)

  19. Smart Tendon Actuated Flexible Actuator

    Directory of Open Access Journals (Sweden)

    Md. Masum Billah

    2015-01-01

    Full Text Available We investigate the kinematic feasibility of a tendon-based flexible parallel platform actuator. Much of the research on tendon-driven Stewart platforms is devoted either to the completely restrained positioning mechanism (CRPM or to one particular type of the incompletely restrained positioning mechanism (IRPM where the external force is provided by the gravitational pull on the platform such as in cable-suspended Stewart platforms. An IRPM-based platform is proposed which uses the external force provided by a compliant member. The compliant central column allows the configuration to achieve n DOFs with n tendons. In particular, this investigation focuses on the angular deflection of the upper platform with respect to the lower platform. The application here is aimed at developing a linkable module that can be connected to one another so as to form a “snake robot” of sorts. Since locomotion takes precedence over positioning in this application, a 3-DOF Stewart platform is adopted. For an arbitrary angular displace of the end-effector, the corresponding length of each tendon can be determined through inverse kinematics. Mathematical singularities are investigated using the traditional analytical method of defining the Jacobian.

  20. Tendon Reattachment to Bone in an Ovine Tendon Defect Model of Retraction Using Allogenic and Xenogenic Demineralised Bone Matrix Incorporated with Mesenchymal Stem Cells.

    Directory of Open Access Journals (Sweden)

    Tanujan Thangarajah

    Full Text Available Tendon-bone healing following rotator cuff repairs is mainly impaired by poor tissue quality. Demineralised bone matrix promotes healing of the tendon-bone interface but its role in the treatment of tendon tears with retraction has not been investigated. We hypothesized that cortical demineralised bone matrix used with minimally manipulated mesenchymal stem cells will result in improved function and restoration of the tendon-bone interface with no difference between xenogenic and allogenic scaffolds.In an ovine model, the patellar tendon was detached from the tibial tuberosity and a complete distal tendon transverse defect measuring 1 cm was created. Suture anchors were used to reattach the tendon and xenogenic demineralised bone matrix + minimally manipulated mesenchymal stem cells (n = 5, or allogenic demineralised bone matrix + minimally manipulated mesenchymal stem cells (n = 5 were used to bridge the defect. Graft incorporation into the tendon and its effect on regeneration of the enthesis was assessed using histomorphometry. Force plate analysis was used to assess functional recovery.Compared to the xenograft, the allograft was associated with significantly higher functional weight bearing at 6 (P = 0.047, 9 (P = 0.028, and 12 weeks (P = 0.009. In the allogenic group this was accompanied by greater remodeling of the demineralised bone matrix into tendon-like tissue in the region of the defect (p = 0.015, and a more direct type of enthesis characterized by significantly more fibrocartilage (p = 0.039. No failures of tendon-bone healing were noted in either group.Demineralised bone matrix used with minimally manipulated mesenchymal stem cells promotes healing of the tendon-bone interface in an ovine model of acute tendon retraction, with superior mechanical and histological results associated with use of an allograft.