WorldWideScience

Sample records for hamamatsu s8148 apd

  1. DOI resolution measurement and error analysis with LYSO and APDs

    International Nuclear Information System (INIS)

    Lee, Chae-hun; Cho, Gyuseong

    2008-01-01

    Spatial resolution degradation in PET occurs at the edge of Field Of View (FOV) due to parallax error. To improve spatial resolution at the edge of FOV, Depth-Of-Interaction (DOI) PET has been investigated and several methods for DOI positioning were proposed. In this paper, a DOI-PET detector module using two 8x4 array avalanche photodiodes (APDs) (Hamamatsu, S8550) and a 2 cm long LYSO scintillation crystal was proposed and its DOI characteristics were investigated experimentally. In order to measure DOI positions, signals from two APDs were compared. Energy resolution was obtained from the sum of two APDs' signals and DOI positioning error was calculated. Finally, an optimum DOI step size in a 2 cm long LYSO were suggested to help to design a DOI-PET

  2. Comparison of SensL and Hamamatsu 4×4 channel SiPM arrays in gamma spectrometry with scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Grodzicka-Kobylka, M., E-mail: m.grodzicka@ncbj.gov.pl; Szczesniak, T.; Moszyński, M.

    2017-06-01

    The market of Silicon Photomultipliers (SiPMs) consists of many manufacturers that produce their detectors in different technology. Hamamatsu (Japan) and SensL (Ireland) seems to be the most popular companies that produce large SiPM arrays. The aim of this work is characterization and comparison of 4×4 channel SiPM arrays produced by these two producers. Both of the tested SiPMs are made in through-silicon via (TSV) technology, consist of 16, 3×3 mm avalanche photodiode (APD) cells and have fill factor slightly above 60%. The largest difference is a single APD cell size and hence total number of APD cells (55,424 for Hamamatsu, 76,640 for SensL). In the case of SensL SiPM, its spectral response characteristics is shifted slightly toward shorter wavelengths with maximum at 420 nm (450 nm for Hamamatsu). The presented measurements cover selection of the SiPM optimum operating voltage (in respect to energy resolution), verification of the excess noise factor and check of the linearity characteristics. Moreover, the gamma spectrometry with LSO, BGO and CsI:Tl scintillators together with pulse characteristics for these crystals (rise time and fall time) is reported, as well as temperature dependence. The presented measurements show better performance of the SensL array comparing to the Hamamatsu detector.

  3. APD Properties and Recovery from Radiation Damage

    CERN Document Server

    Baccaro, Stefania; Caruso, S; Cavallari, Francesca; Dafinei, Ioan; Diemoz, Marcella; Emeliantchik, Igor; Festinesi, Armando; Longo, Egidio; Montecchi, Marco; Organtini, Giovanni; Rosi, G

    1997-01-01

    Avalanche photodiodes will be used to detect scintillation light from PWO crystals in the CMS electromagnetic calorimeter. Properties of Hamamatsu APD are reported special attention has been devoted to the study of radiation hardness and room temperature annealing. We found a fast recovery with a time constant of 1.3 days a medium fast recovery with a lifetime of the order of 10 days and indication of a third component with very long time constant of the order of 300 days.

  4. 40 CFR 81.48 - Champlain Valley Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.48 Section 81.48 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.48 Champlain Valley Interstate Air Quality Control Region. The Champlain Valley Interstate Air Quality Control Region (Vermont-New York) has been revised to consist of the...

  5. Study of a pure CsI crystal readout by APD for Belle II end cap ECL upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Y., E-mail: jin@hep.phys.s.u-tokyo.ac.jp [Department of Physics, the University of Tokyo, 7-3-1 Hongo Bunkyo-ku, Tokyo 113-0033 (Japan); Aihara, H. [Department of Physics, the University of Tokyo, 7-3-1 Hongo Bunkyo-ku, Tokyo 113-0033 (Japan); Borshchev, O.V. [Enikolopov Institute of Synthetic Polymeric Materials of the Russian Academy of Sciences, Profsoyuznaya st. 70, Moscow 117393 (Russian Federation); Epifanov, D.A. [Department of Physics, the University of Tokyo, 7-3-1 Hongo Bunkyo-ku, Tokyo 113-0033 (Japan); Ponomarenko, S.A.; Surin, N.M. [Enikolopov Institute of Synthetic Polymeric Materials of the Russian Academy of Sciences, Profsoyuznaya st. 70, Moscow 117393 (Russian Federation)

    2016-07-11

    A scintillation counter consisting of a pure CsI crystal and avalanche photodiodes (Hamamatsu APD S8664-55 and S8664-1010) has been studied for the upgrade of the end cap electromagnetic calorimeter of Belle II detector. An essential increase of the light output was achieved with wavelength shifters based on nanostructured organosilicon luminophores. - Highlights: • A scintillation counter consisting of a pure CsI crystal and avalanche photodiodes has been studied. • The equivalent noise charge and equivalent noise energy of the counter have been measured. • An essential increase of the light output was achieved with wavelength shifters.

  6. Experimental characterization of the 192 channel Clear-PEM frontend ASIC coupled to a multi-pixel APD readout of LYSO:Ce crystals

    International Nuclear Information System (INIS)

    Albuquerque, Edgar; Bexiga, Vasco; Bugalho, Ricardo; Carrico, Bruno; Ferreira, Claudia S.; Ferreira, Miguel; Godinho, Joaquim; Goncalves, Fernando; Leong, Carlos; Lousa, Pedro; Machado, Pedro; Moura, Rui; Neves, Pedro; Ortigao, Catarina; Piedade, Fernando; Pinheiro, Joao F.; Rego, Joel; Rivetti, Angelo; Rodrigues, Pedro; Silva, Jose C.

    2009-01-01

    In the framework of the Clear-PEM project for the construction of a high-resolution scanner for breast cancer imaging, a very compact and dense frontend electronics system has been developed for readout of multi-pixel S8550 Hamamatsu APDs. The frontend electronics are instrumented with a mixed-signal Application-Specific Integrated Circuit (ASIC), which incorporates 192 low-noise charge pre-amplifiers, shapers, analog memory cells and digital control blocks. Pulses are continuously stored in memory cells at clock frequency. Channels above a common threshold voltage are readout for digitization by off-chip free-sampling ADCs. The ASIC has a size of 7.3x9.8mm 2 and was implemented in a AMS 0.35μm CMOS technology. In this paper the experimental characterization of the Clear-PEM frontend ASIC, reading out multi-pixel APDs coupled to LYSO:Ce crystal matrices, is presented. The chips were mounted on a custom test board connected to six APD arrays and to the data acquisition system. Six 32-pixel LYSO:Ce crystal matrices coupled on both sides to APD arrays were readout by two test boards. All 384 channels were operational. The chip power consumption is 660 mW (3.4 mW per channel). A very stable behavior of the chip was observed, with an estimated ENC of 1200-1300e - at APD gain 100. The inter-channel noise dispersion and mean baseline variation is less than 8% and 0.5%, respectively. The spread in the gain between different channels is found to be 1.5%. Energy resolution of 16.5% at 511 keV and 12.8% at 662 keV has been measured. Timing measurements between the two APDs that readout the same crystal is extracted and compared with detailed Monte Carlo simulations. At 511 keV the measured single photon time RMS resolution is 1.30 ns, in very good agreement with the expected value of 1.34 ns.

  7. Commissioning of the new GMOS-N Hamamatsu CCDs

    Science.gov (United States)

    Scharwaechter, Julia; Chiboucas, Kristin; Gimeno, German; Boucher, Luc; White, John; Tapia, Eduardo; Lundquist, Michael; Rippa, Mathew; Labrie, Kathleen; Murowinski, Richard; Lazo, Manuel; Miller, Jennifer

    2017-06-01

    We report on the commissioning of the new Hamamatsu fully-depleted CCDs for GMOS-N, installed in the instrument in February 2017. The Hamamatsu detectors replace the e2v deep depletion devices which had been in operation since 2011. The new GMOS-N detector array is expected to provide improved red sensitivity compared to the e2v devices at wavelengths longer than ~900 nm. The commissioning of the new detector array for GMOS-N marks the final step in upgrading the two GMOS instruments at Gemini North and South with Hamamatsu detectors.

  8. Wavelength shifter strips and G-APD arrays for the read-out of the z-coordinate in axial PET modules

    CERN Document Server

    Braem, André; Joram, C; Rudge, A; Séguinot, Jacques; Weilhammer, P; De Leo, R; Nappi, E; Lustermann, W; Schinzel, D; Johnson, I; Renker, D; Albrecht, S

    2008-01-01

    The measurements presented in this paper are related to the development of a PET camera based on a 3-D axial geometry with excellent 3-D spatial, timing and energy resolution. The detector modules consist of matrices of long axially oriented scintillation crystal bars, which are individually coupled to photodetectors. The axial coordinate is derived from wavelength shifting (WLS) plastic strips orthogonally interleaved between the crystal bars and readout by G-APD arrays. We report on results from measurements with two LYSO crystal bars, read with PMTs, and two WLS strips readout with G-APD devices from Hamamatsu (called MPPC). The WLS strips are positioned orthogonally underneath the LYSO bars. Yields of about 80 photoelectrons from the WLS strips for an energy deposition in the LYSO crystals equivalent to the absorption of 511 keV photons are observed. The axial coordinate in the LYSO bars is reconstructed with a precision of about 1.9 mm (FWHM) using a digital reconstruction method. The resolution of an an...

  9. APD arrays and large-area APDs via a new planar process

    CERN Document Server

    Farrell, R; Vanderpuye, K; Grazioso, R; Myers, R; Entine, G

    2000-01-01

    A fabrication process has been developed which allows the beveled-edge-type of avalanche photodiode (APD) to be made without the need for the artful bevel formation steps. This new process, applicable to both APD arrays and to discrete detectors, greatly simplifies manufacture and should lead to significant cost reduction for such photodetectors. This is achieved through a simple innovation that allows isolation around the device or array pixel to be brought into the plane of the surface of the silicon wafer, hence a planar process. A description of the new process is presented along with performance data for a variety of APD device and array configurations. APD array pixel gains in excess of 10 000 have been measured. Array pixel coincidence timing resolution of less than 5 ns has been demonstrated. An energy resolution of 6% for 662 keV gamma-rays using a CsI(T1) scintillator on a planar processed large-area APD has been recorded. Discrete APDs with active areas up to 13 cm sup 2 have been operated.

  10. Investigation of avalanche photodiodes

    Energy Technology Data Exchange (ETDEWEB)

    Si Mohand, D.; Benhammou, Y.; Depasse, P.; Goyot, M.; Ille, B.; Linard, E.; Martin, F.; Musienko, Y.

    1996-06-01

    Some characteristics and performances of a set of nine Hamamatsu avalanche photodiodes have been investigated. These APDs have equipped a small 3x3 PbWO{sub 4} crystal matrix in X3 beam during the summer of 1995. This note summarizes the main results of this work. An electromagnetic calorimeter with a high resolution is necessary to search for the Higgs if it has a mass between 80 and 160 GeV. A PbWO{sub 4} crystal option has been chosen by the CMS collaboration to achieve this task. The light is collected and converted into an electric charge by an Avalanche Photodiode (APD) followed by a fast preamplifier. The advantage of the APDs is that they are not sensitive to the strong magnetic field when compared to photomultipliers and they are a small nuclear counter effect when compared to PIN diodes. In this study, we have tested nine low capacitance Hamamatsu APDs (S5345) received in spring, 1995 with an area of 0.2 cm{sup 2}. We have measured the capacitance and dark current for each APD. The gain measurements have also been done with gamma sources, continuous and pulsed light. The gain sensitivity versus bias and temperature have also been investigated succinctly. (author). 8 refs., 16 figs., 1 tab.

  11. Investigation of avalanche photodiodes

    International Nuclear Information System (INIS)

    Si Mohand, D.; Benhammou, Y.; Depasse, P.; Goyot, M.; Ille, B.; Linard, E.; Martin, F.; Musienko, Y.

    1996-06-01

    Some characteristics and performances of a set of nine Hamamatsu avalanche photodiodes have been investigated. These APDs have equipped a small 3x3 PbWO 4 crystal matrix in X3 beam during the summer of 1995. This note summarizes the main results of this work. An electromagnetic calorimeter with a high resolution is necessary to search for the Higgs if it has a mass between 80 and 160 GeV. A PbWO 4 crystal option has been chosen by the CMS collaboration to achieve this task. The light is collected and converted into an electric charge by an Avalanche Photodiode (APD) followed by a fast preamplifier. The advantage of the APDs is that they are not sensitive to the strong magnetic field when compared to photomultipliers and they are a small nuclear counter effect when compared to PIN diodes. In this study, we have tested nine low capacitance Hamamatsu APDs (S5345) received in spring, 1995 with an area of 0.2 cm 2 . We have measured the capacitance and dark current for each APD. The gain measurements have also been done with gamma sources, continuous and pulsed light. The gain sensitivity versus bias and temperature have also been investigated succinctly. (author). 8 refs., 16 figs., 1 tab

  12. G-APDs in Cherenkov astronomy: The FACT camera

    International Nuclear Information System (INIS)

    Krähenbühl, T.; Anderhub, H.; Backes, M.; Biland, A.; Boller, A.; Braun, I.; Bretz, T.; Commichau, V.; Djambazov, L.; Dorner, D.; Farnier, C.; Gendotti, A.; Grimm, O.; Gunten, H. von; Hildebrand, D.; Horisberger, U.; Huber, B.; Kim, K.-S.; Köhne, J.-H.; Krumm, B.

    2012-01-01

    Geiger-mode avalanche photodiodes (G-APD, SiPM) are a much discussed alternative to photomultiplier tubes in Cherenkov astronomy. The First G-APD Cherenkov Telescope (FACT) collaboration builds a camera based on a hexagonal array of 1440 G-APDs and has now finalized its construction phase. A light-collecting solid PMMA cone is glued to each G-APD to eliminate dead space between the G-APDs by increasing the active area, and to restrict the light collection angle of the sensor to the reflector area in order to reduce the amount of background light. The processing of the signals is integrated in the camera and includes the digitization using the domino ring sampling chip DRS4.

  13. Testing limits to airflow perturbation device (APD measurements

    Directory of Open Access Journals (Sweden)

    Jamshidi Shaya

    2008-10-01

    Full Text Available Abstract Background The Airflow Perturbation Device (APD is a lightweight, portable device that can be used to measure total respiratory resistance as well as inhalation and exhalation resistances. There is a need to determine limits to the accuracy of APD measurements for different conditions likely to occur: leaks around the mouthpiece, use of an oronasal mask, and the addition of resistance in the respiratory system. Also, there is a need for resistance measurements in patients who are ventilated. Method Ten subjects between the ages of 18 and 35 were tested for each station in the experiment. The first station involved testing the effects of leaks of known sizes on APD measurements. The second station tested the use of an oronasal mask used in conjunction with the APD during nose and mouth breathing. The third station tested the effects of two different resistances added in series with the APD mouthpiece. The fourth station tested the usage of a flexible ventilator tube in conjunction with the APD. Results All leaks reduced APD resistance measurement values. Leaks represented by two 3.2 mm diameter tubes reduced measured resistance by about 10% (4.2 cmH2O·sec/L for control and 3.9 cm H2O·sec/L for the leak. This was not statistically significant. Larger leaks given by 4.8 and 6.4 mm tubes reduced measurements significantly (3.4 and 3.0 cm cmH2O·sec/L, respectively. Mouth resistance measured with a cardboard mouthpiece gave an APD measurement of 4.2 cm H2O·sec/L and mouth resistance measured with an oronasal mask was 4.5 cm H2O·sec/L; the two were not significantly different. Nose resistance measured with the oronasal mask was 7.6 cm H2O·sec/L. Adding airflow resistances of 1.12 and 2.10 cm H2O·sec/L to the breathing circuit between the mouth and APD yielded respiratory resistance values higher than the control by 0.7 and 2.0 cm H2O·sec/L. Although breathing through a 52 cm length of flexible ventilator tubing reduced the APD

  14. Recent measurements on the Hamamatsu 13 in., R8055, PhotoMultiplier Tubes

    International Nuclear Information System (INIS)

    Tsagli, S.; Aggouras, G.; Anassontzis, E.G.; Ball, A.E.; Chinowsky, W.; Fahrun, E.; Grammatikakis, G.; Green, C.; Grieder, P.; Katrivanos, P.; Koske, P.; Ludvig, J.; Markopoulos, E.; Minkowsky, P.; Nygren, D.; Papageorgiou, K.; Przybylski, G.; Resvanis, L.K.; Siotis, I.; Sopher, J.; Staveris, T.; Tsagli, V.; Zhukov, V.A.

    2006-01-01

    The key component of NESTOR, the deep-sea Cherenkov neutrino telescope, built in the Mediterranean, NW of Greece, is the optical module. The NESTOR Optical Module employs a PhotoMultiplier Tube (PMT) in a transparent glass pressure housing. The Hamamatsu PMT R8055-01, 13 in. photomultiplier was selected for NESTOR to replace the old 15'' Hamamatsu PMTs (R2018-03). Extensive tests have been made on the sensitivity, uniformity, time resolution and noise rates of 162 R8055-01 13 in. PMTs

  15. A G-APD based Camera for Imaging Atmospheric Cherenkov Telescopes

    International Nuclear Information System (INIS)

    Anderhub, H.; Backes, M.; Biland, A.; Boller, A.; Braun, I.; Bretz, T.; Commichau, S.; Commichau, V.; Dorner, D.; Gendotti, A.; Grimm, O.; Gunten, H. von; Hildebrand, D.; Horisberger, U.; Koehne, J.-H.; Kraehenbuehl, T.; Kranich, D.; Lorenz, E.; Lustermann, W.; Mannheim, K.

    2011-01-01

    Imaging Atmospheric Cherenkov Telescopes (IACT) for Gamma-ray astronomy are presently using photomultiplier tubes as photo sensors. Geiger-mode avalanche photodiodes (G-APD) promise an improvement in sensitivity and, important for this application, ease of construction, operation and ruggedness. G-APDs have proven many of their features in the laboratory, but a qualified assessment of their performance in an IACT camera is best undertaken with a prototype. This paper describes the design and construction of a full-scale camera based on G-APDs realized within the FACT project (First G-APD Cherenkov Telescope).

  16. A simple model of EG and G reverse reach-through APDs

    CERN Document Server

    Musienko, Y; Swain, J D

    2000-01-01

    A simple model of reverse reach-through APDs is described. APD parameters including the dependence of the electric field and gain on the bias voltage, dependence of gain on wavelength are calculated using the McIntyre approach and an assumed doping profile of the APD.

  17. A simple model of EG and G reverse reach-through APDs

    Energy Technology Data Exchange (ETDEWEB)

    Musienko, Y. E-mail: iouri.moussienko@cern.ch; Reucroft, S.; Swain, J

    2000-03-11

    A simple model of reverse reach-through APDs is described. APD parameters including the dependence of the electric field and gain on the bias voltage, dependence of gain on wavelength are calculated using the McIntyre approach and an assumed doping profile of the APD.

  18. An advanced APD-based spectroscopic radiation monitor. Final Technical Report

    International Nuclear Information System (INIS)

    Mitchell Woodring, PhD; James Christian, PhD

    2007-01-01

    A highly sensitized radiation imager is under development through DOE SBIR contract DE-FG02-99ER 82866. This imager will be extraordinarily useful to the DOE in its decontamination and decommissioning activities. The basis for this advanced, state-of-the-art radiation imager is a new type of photon detector, an avalanche photodiode (APD). Only recently has APD technology advanced to the point where it is useful for applications like the radiation imager. To date, the major drawback in the use of avalanche photodiodes was the inability to use many of them in a single application because of the need for many channels of readout, complicated device holders, and dead space between detectors. RMD has solved this dilemma through the development of compact arrays of APDs. Additionally, the fabrication technique has been refined to the point were the bulk production of large quantities of arrays is now feasible. These new APD arrays have excellent application flexibility. The capability to tailor the detector properties; such as size, sensitivity, pixellation, and pitch make APD arrays excellent candidates for a variety of photosensing schemes previously dominated by photomultiplier tubes (PMT). In fact, at RMD it is currently possible to make APD arrays with 2-mm 2 detectors (pixels) in monolithic square arrays 14 pixels on a side (196 detectors). As proposed in Phase II work, paneling 9 of these arrays (as the basis of a highly sensitive radiation imager) would make a photodetector that was 100 cm 2 in sensitive area. This results in approximately 1800 individual detectors that require data sampling and control. This is an enormous electronics load. To reduce the electronics complexity for the readout scheme of APD arrays (one of the major aspects of the proposed Phase II research) individual detectors (in the array) will be grouped together on common readout lines by rows and columns. This row-column-addressing scheme reduces the readout complexity from 1800 to 90 if 42

  19. Study on APD real time compensation methods of laser Detection system

    Energy Technology Data Exchange (ETDEWEB)

    Feng Ying; Zhang He; Zhang Xiangjin; Liu Kun, E-mail: fy_caimi@163.com [ZNDY of Ministerial Key Laboratory, Nanjing University of Science and Technology, Nanjing 210094 (China)

    2011-02-01

    With the monochromatic and the directional capability of the laser, laser detection system is confidential in anti-jamming. Detection accuracy is improved significantly as the result of laser's good orientation ability. Sensitivity is enhanced as laser's high-brightness characteristic. With the development of laser technology and laser devices, laser detections are developed both in civilian and military areas. In the military field, laser detection system has been widely applied in various types of tactical missiles, the technique is more mature. Because photo detectors receive the backscattering echo signal of target in laser detection system, they are required sensitive enough to weak signal. With APD's salient features of high sensitivity, rapid response speed, high response frequency and low noise equivalent power, etc.; PIN is replaced by APD to improve sensitivity of laser detection system in recent years. The signal magnification is inadequate in laser detection system, the detector output is usually amplified by multistage amplifiers. And then the system noise includes detector noise and latter amplifiers noise. With its high internal gain, APD becomes the primary noise source of receiving system. This point can be attested by analyzing the transfer function of laser detection system receiver. To ensure the system detecting ability, APD noise must be mitigated as low as possible. According to a large number of experiments, the power signal-to-noise (SNR) and the best multiplication factor of APD are mostly affected by background radiation and temperature. In order to make APD operate at state of the best multiplication factor, the optimum bias must be selected due to the actual operating circumstance. Therefore, APD realtime compensation must be adopted. The existing APD compensation includes the constant false alarm rate compensation, the noise compensation and the temperature compensation. The features of these compensations are obtained

  20. A method to stabilize the temperature dependent performance of G-APD arrays

    Energy Technology Data Exchange (ETDEWEB)

    Huh, Yoonsuk [Molecular Imaging Research and Education (MiRe) Laboratory, Department of Electronic Engineering, Sogang University, Seoul (Korea, Republic of); Sungkyunkwan University, School of Medicine, Seoul (Korea, Republic of); Choi, Yong; Ho Jung, Jin; Jung, Jiwoong [Molecular Imaging Research and Education (MiRe) Laboratory, Department of Electronic Engineering, Sogang University, Seoul (Korea, Republic of)

    2015-02-01

    This paper presents a compensation method to stabilize the temperature dependent performance of Geiger-mode Avalanche Photodiode (G-APD) arrays for Positron Emission Tomography (PET). The compensation method is used to identify the bias voltage range that provides stable performance even at different temperatures using the G-APD’s characteristics, and to control the photo-peak variation as a function of temperature using the preamplifier gain within the identified bias voltage range. A pair of G-APD detectors and temperature sensors were located in the temperature chamber and the preamplifiers which can control the gain of the detectors using the digital potentiometer were positioned outside the chamber. The performance of the G-APD detector, especially energy resolution and coincidence timing resolution, was characterized as a function of bias voltage at different temperatures from 20 °C to 40 °C at 5 °C increments; the energy resolution, coincidence timing resolution, and photo-peak position of all channels of G-APD PET detectors before and after the preamplifier gain correction were then measured and compared. The results of this study demonstrated that the optimal bias voltage range providing the good energy and coincidence timing resolution, 12.1±1.2% and 1.30±0.09 ns, respectively, could be identified at the temperature range and the photo-peak variation and the performance at different temperatures could be stabilized by adjusting the preamplifier gain within the identified bias voltage range. We concluded the proposed method to be reliable and useful for the development of the PET system using G-APD arrays.

  1. First characterization of the Hamamatsu R11265 multi-anode photomultiplier tube

    International Nuclear Information System (INIS)

    Calvi, M.; Cassina, L.; Giachero, A.; Gotti, C.; Maino, M.; Matteuzzi, C.; Pessina, G.

    2014-01-01

    The characterization of the new Hamamatsu R11265-103-M64 multi-anode photomultiplier tube is presented. The sample available in our laboratory was tested and in particular the response to single photon was extensively studied. The gain, the anode uniformity and the dark current were measured. The tube behaviour in a longitudinal magnetic field up to 100 G was studied and the gain loss due to the ageing was quantified. The characteristics and performance of the photomultiplier tube make the R11265-103-M64 particularly tailored for an application in high energy physics experiments, such as in the LHCb Ring Imaging Cherenkov (RICH) detector at LHC. - Highlights: • We tested the new Hamamatsu R11265-103-M64 multi-anode photomultiplier tube. • We studied the response to single photon, the gain and the anode uniformity. • The tube behaviour in a longitudinal magnetic field up to 100 G was studied. • The gain loss due to the aging was quantified

  2. Optical Communications With A Geiger Mode APD Array

    Science.gov (United States)

    2016-02-09

    practical performance of a Geiger mode avalanche photodiode ( GM -APD, or Geiger mode APD) array for use in optical com- munications systems. I designed and...signal quality in the first half of the frame. These shorter reset times also did not offer any advantage in the maximum number of counts able to be...pattern was advantageous for the modifications being made in post-processing on the benchmark data. In particular, this allowed post-processing results

  3. Characterization of irradiated APDs for picosecond time measurements

    Science.gov (United States)

    Centis Vignali, M.; Dalal, R.; Gallinaro, M.; Harrop, B.; Jain, G.; Lu, C.; McClish, M.; McDonald, K. T.; Moll, M.; Newcomer, F. M.; Ugobono, S. Otero; White, S.

    2018-01-01

    For their operation at the CERN High Luminosity Large Hadron Collider (HL-LHC), the ATLAS and CMS experiments are planning to implement dedicated systems to measure the time of arrival of minimum ionizing particles with an accuracy of about 30 ps. The timing detectors will be subjected to radiation levels corresponding up to a 1-MeV neutrons fluence (Φeq) of 1015 cm-2 for the goal integrated luminosity of HL-LHC of 3000 fb-1. In this paper, deep-diffused Avalanche Photo Diodes (APDs) produced by Radiation Monitoring Devices are examined as candidate timing detectors for HL-LHC applications. These APDs are operated at 1.8 kV, resulting in a gain of up to 500. The timing performance of the detectors is evaluated using a pulsed laser. The effects of radiation damage on current, signal amplitude, noise, and timing performance of the APDs are evaluated using detectors irradiated with neutrons up to Φeq = 1015 cm-2.

  4. Temperature dependence of APD-based PET scanners

    International Nuclear Information System (INIS)

    Keereman, Vincent; Van Holen, Roel; Vandenberghe, Stefaan; Vanhove, Christian

    2013-01-01

    Purpose: Solid state detectors such as avalanche photodiodes (APDs) are increasingly being used in PET detectors. One of the disadvantages of APDs is the strong decrease of their gain factor with increasing ambient temperature. The light yield of most scintillation crystals also decreases when ambient temperature is increased. Both effects lead to considerable temperature dependence of the performance of APD-based PET scanners. In this paper, the authors propose a model for this dependence and the performance of the LabPET8 APD-based small animal PET scanner is evaluated at different temperatures.Methods: The model proposes that the effect of increasing temperature on the energy histogram of an APD-based PET scanner is a compression of the histogram along the energy axis. The energy histogram of the LabPET system was acquired at 21 °C and 25 °C to verify the validity of this model. Using the proposed model, the effect of temperature on system sensitivity was simulated for different detector temperature coefficients and temperatures. Subsequently, the effect of short term and long term temperature changes on the peak sensitivity of the LabPET system was measured. The axial sensitivity profile was measured at 21 °C and 24 °C following the NEMA NU 4-2008 standard. System spatial resolution was also evaluated. Furthermore, scatter fraction, count losses and random coincidences were evaluated at different temperatures. Image quality was also investigated.Results: As predicted by the model, the photopeak energy at 25 °C is lower than at 21 °C with a shift of approximately 6% per °C. Simulations showed that this results in an approximately linear decrease of sensitivity when temperature is increased from 21 °C to 24 °C and energy thresholds are constant. Experimental evaluation of the peak sensitivity at different temperatures showed a strong linear correlation for short term (2.32 kcps/MBq/°C = 12%/°C, R = −0.95) and long term (1.92 kcps/MBq/°C = 10%/

  5. Epstein–Barr Virus Susceptibility in Activated PI3Kδ Syndrome (APDS Immunodeficiency

    Directory of Open Access Journals (Sweden)

    Jean-Marie Carpier

    2018-01-01

    Full Text Available Activated PI3Kδ Syndrome (APDS is an inherited immune disorder caused by heterozygous, gain-of-function mutations in the genes encoding the phosphoinositide 3-kinase delta (PI3Kδ subunits p110δ or p85δ. This recently described primary immunodeficiency disease (PID is characterized by recurrent sinopulmonary infections, lymphoproliferation, and susceptibility to herpesviruses, with Epstein–Barr virus (EBV infection being most notable. A broad range of PIDs having disparate, molecularly defined genetic etiology can cause susceptibility to EBV, lymphoproliferative disease, and lymphoma. Historically, PID patients with loss-of-function mutations causing defective cell-mediated cytotoxicity or antigen receptor signaling were found to be highly susceptible to pathological EBV infection. By contrast, the gain of function in PI3K signaling observed in APDS patients paradoxically renders these patients susceptible to EBV, though the underlying mechanisms are incompletely understood. At a cellular level, APDS patients exhibit deranged B lymphocyte development and defects in class switch recombination, which generally lead to defective immunoglobulin production. Moreover, APDS patients also demonstrate an abnormal skewing of T cells toward terminal effectors with short telomeres and senescence markers. Here, we review APDS with a particular focus on how the altered lymphocyte biology in these patients may confer EBV susceptibility.

  6. Characterization of the 10-stages R5900 Hamamatsu photomultipliers for the hadronic ATLAS calorimeter

    International Nuclear Information System (INIS)

    Montarou, G.; Bouhemaid, N.; Grenier, Ph.; Crouau, M.; Muanza, G.S.; Poirot, S.; Vazeille, F.; Gil Botella, I.; Hoz, S.G. de la

    1997-01-01

    The measurements carried out, at Clermont on the R5900 Hamamatsu photomultipliers for the ATLAS hadronic calorimeter are summarised. The TILECAL specifications are given. Amplification measurements, dark current measurements, linearity, magnetic sensitivity and the voltage divider optimisation are presented. (K.A.)

  7. Characterisation of the Hamamatsu photomultipliers for the KM3NeT Neutrino Telescope

    NARCIS (Netherlands)

    Aiello, S.; Akrame, S.E.; Amélineau, F.; Anassontzis, E.G.; Andre, M.; Androulakis, G.; Anghinolfi; Anton, G.; Ardid, M.; Aublin, J.; Avgitas, T.; Baars, M.; Bagatelas, C.; Barbarino, G.; Baret, B.; Barrios-Martí, J.; Belias, A.; Berbee, E.; van den Berg, A.; Bertin, V.; Biagi, S.; Biagioni, A.; Biernoth, C.; Bormuth, R.; Boumaaza, J.; Bourret, S.; Bouwhuis, M.; Bozza, C.; Brânzas, H.; Briukhanova, N.; Bruijn, R.; Brunner, J.; Buis, E.; Buompane, R,; Busto, J.; Calvo, D.; Capone, A.; Caramete, L.; Celli, S.; Chabab, M.; Cherubini, S.; Chiarella, V.; Chiarusi, T.; Circella, M.; Cocimano, R.; Coelho, J.A.B.; Coleiro, A.; Molla, M.C.; Coniglione, R.; Coyle, P.; Creusot, A.; Cuttone, G.; D’Onofrio, A.; Dallier, R.; De Sio, C.; Di Palma, I.; Díaz, A.F.; Distefano, C.; Domi, A.; Donà, R.; Donzaud, C.; Dornic, D.; Dörr, M.; Durocher, M.; Eberl, T.; Van Eijk, D.; El Bojaddaini, I.; Elsaesser, D.; Enzenhöfer, A.; Ferrara, G.; Fusco, L.A.; Gal, T.; Garufi, F.; Gauchery, S.; Geißelsöder, S.; Gialanella, L.; Giorgio, E.; Giuliante, A.; Gozzini, S.R.; Gracia-Ruiz, R.; Graf, K.; Grasso, D.; Grégoire, T.; Grella, G.; Hallmann, S.; van Haren, H.; Heid, T.; Heijboer, A.; Hekalo, A.; Hernandez-Rey, J.J.; Hofestädt, J.; Illuminati, G.; James, C.W.; Jongen, M.; Jongewaard, B.; de Jong, M.; de Jong, P.; Kadler, M.; Kalaczynski, P.; Kalekin, O.; Katz, U.F.; Khan Chowdhury, N.R.; Kieft, G.; Kießling, D.; Koffeman, E.N.; Kooijman, P.; Kouchner, A.; Kreter, M.; Kulikovskiy, V.; Lahmann, R.; Le Breton, A.; Leone, F.; Leonora, E.; Levi, G.; Lincetto, M.; Lonardo, A.; Longhitano, F.; Lotze, M.; Loucatos, S.; Maggi, G.; Manczak, J.; Mannheim, K.; Margiotta, A.; Marinelli, A.; Markou, C.; Martin, L.; Martínez-Mora, J.A.; Martini, A.; Marzaioli, F.; Mele, R.; Melis, K.W.; Migliozzi, P.; Migneco, E.; Mijakowski, P.; Mollo, C.M.; Morganti, M.; Moser, M.; Moussa, A.; Muller, R.; Musumeci, M.; Nauta, L.; Navas, S.; Nicolau, C.A.; Nielsen, C.; Organokov, M.; Orlando, A.; Panagopoulos, V.; Papalashvili, G.; Papaleo, R.; Pavalas, G.E.; Pellegrini, G.; Pellegrino, C.; Pérez Romero, J.; Perrin-Terrin, M.; Piattelli, P.; Pikounis, K.; Pisanti, O.; Poirè, C.; Polydefki, G.; Poma, G.E.; Popa, V.; Post, M.; Pradier, T.; Pühlhofer, G.; Pulvirenti, S.; Quinn, L.; Raffaelli, F.; Randazzo, N.; Razzaque, S.; Real, D.; Resvanis, L.; Reubelt, J.; Riccobene, G.; Richer, M.; Rovelli, A.; Salvadori, I.; Samtleben, D.F.E.; Sánchez-Losa, A.; Sanguineti, M.; Santangelo, A.; Sapienza, P.; Schermer, B.; Sciacca, V.; Seneca, J.; Sgura, I.; Shanidze, R.; Sharma, A.; Simeone, F.; Sinopoulou, A.; Spisso, B.; Spurio, M.; Stavropoulos, D.; Steijger, J.; Stellacci, S.M.; Strandberg, B.; Stransky, D.; Stüven, T.; Taiuti, M.; Tatone, F.; Tayalati, Y.; Tenllado, E.; Thakore, T.; Timmer, P.; Trovato, A.; Tsagkli, S.; Tzamariudaki, E.; Tzanetatos, D.; Valieri, C.; Vallage, B.; Van Elewyck, V.; Versari, F.; Viola, S.; Vivolo, D.; Volkert, M.; de Waardt, L.; Wilms, J.; de Wolf, E.; Zaborov, D.; Zornoza, J.D.; Zúñiga, J.

    2018-01-01

    The Hamamatsu R12199-02 3-inch photomultiplier tube is the photodetector chosen for the first phase of the KM3NeT neutrino telescope. About 7000 photomultipliers have been characterised for dark count rate, timing spread and spurious pulses. The quantum efficiency, the gain and the peak-to-valley

  8. Compact and high-sensitivity 100-Gb/s (4 × 25 Gb/s) APD-ROSA with a LAN-WDM PLC demultiplexer.

    Science.gov (United States)

    Yoshimatsu, Toshihide; Nada, Masahiro; Oguma, Manabu; Yokoyama, Haruki; Ohno, Tetsuichiro; Doi, Yoshiyuki; Ogawa, Ikuo; Takahashi, Hiroshi; Yoshida, Eiji

    2012-12-10

    We demonstrate an integrated 100 GbE receiver optical sub-assembly (ROSA) that incorporates a monolithic four-channel avalanche photodiode (APD) array and a planer lightwave circuit (PLC) based LAN-WDM demultiplexer. A record minimum receiver sensitivity of -20 dBm and 50-km error-free SMF transmission without an optical amplifier have been achieved.

  9. Multiple benefits of personal FM system use by children with auditory processing disorder (APD).

    Science.gov (United States)

    Johnston, Kristin N; John, Andrew B; Kreisman, Nicole V; Hall, James W; Crandell, Carl C

    2009-01-01

    Children with auditory processing disorders (APD) were fitted with Phonak EduLink FM devices for home and classroom use. Baseline measures of the children with APD, prior to FM use, documented significantly lower speech-perception scores, evidence of decreased academic performance, and psychosocial problems in comparison to an age- and gender-matched control group. Repeated measures during the school year demonstrated speech-perception improvement in noisy classroom environments as well as significant academic and psychosocial benefits. Compared with the control group, the children with APD showed greater speech-perception advantage with FM technology. Notably, after prolonged FM use, even unaided (no FM device) speech-perception performance was improved in the children with APD, suggesting the possibility of fundamentally enhanced auditory system function.

  10. Scintillation counter with MRS APD light readout

    International Nuclear Information System (INIS)

    Akindinov, A.; Bondarenko, G.; Golovin, V.; Grigoriev, E.; Grishuk, Yu.; Mal'kevich, D.; Martemiyanov, A.; Ryabinin, M.; Smirnitskiy, A.; Voloshin, K.

    2005-01-01

    START, a high-efficiency and low-noise scintillation detector for ionizing particles, was developed for the purpose of creating a high-granular system for triggering cosmic muons. Scintillation light in START is detected by MRS APDs (Avalanche Photo-Diodes with Metal-Resistance-Semiconductor Structure), operated in the Geiger mode, which have 1mm 2 sensitive areas. START is assembled from a 15x15x1cm 3 scintillating plastic plate, two MRS APDs and two pieces of wavelength-shifting optical fiber stacked in circular coils inside the plastic. The front-end electronic card is mounted directly on the detector. Tests with START have confirmed its operational consistency, over 99% efficiency of MIP registration and good homogeneity. START demonstrates a low intrinsic noise of about 10 -2 Hz. If these detectors are to be mass-produced, the cost of a mosaic array of STARTs is estimated at a moderate level of 2-3kUSD/m 2

  11. Detectors for proton counting. Si-APD and scintillation detectors

    International Nuclear Information System (INIS)

    Kishimoto, Shunji

    2008-01-01

    Increased intensity of synchrotron radiation requests users to prepare photon pulse detectors having higher counting rates. As detectors for photon counting, silicon-avalanche photodiode (Si-APD) and scintillation detectors were chosen for the fifth series of detectors. Principle of photon detection by pulse and need of amplification function of the detector were described. Structure and working principle, high counting rate measurement system, bunch of electrons vs. counting rate, application example of NMR time spectroscopy measurement and comments for users were described for the Si-APD detector. Structure of scintillator and photomultiplier tube, characteristics of scintillator and performance of detector were shown for the NaI detector. Future development of photon pulse detectors was discussed. (T. Tanaka)

  12. Characterization of Hamamatsu 64-channel TSV SiPMs

    Science.gov (United States)

    Renschler, Max; Painter, William; Bisconti, Francesca; Haungs, Andreas; Huber, Thomas; Karus, Michael; Schieler, Harald; Weindl, Andreas

    2018-04-01

    The Hamamatsu UV-light enhanced 64-channel SiPM array of the newest generation (S13361-3050AS-08) has been examined for the purpose of being used for the Silicon Elementary Cell Add-on (SiECA) of the EUSO-SPB balloon experiment. At a room temperature of 19 . 5 °C, the average measured breakdown voltage of the array is (51 . 65 ± 0 . 11) V, the average gain is measured to (2 . 10 ± 0 . 07) ṡ 106 and the average photon detection efficiency results to (44 . 58 ± 1 . 80) % at a wavelength of (423 ± 8) nm and a bias voltage of 55 . 2V. The average dark-count rate is (0 . 69 ± 0 . 12) MHz, equivalent to a dark count rate per SiPM area of (57 ± 12) kHz /mm2, and the crosstalk probability is measured to (3 . 96 ± 0 . 64) %. These results confirm the information given by the manufacturer. Measurements performed with the newly installed Single Photon Calibration Stand at KIT (SPOCK) show the improved sensitivity to photons with wavelengths lower than 400 nm compared to the SiPM array S12642-0808PA-50, which was also investigated for comparison. Additional measurements confirm the strong temperature dependence of the SiPM characteristics as given in the data sheet. All the characterized parameters appear to be sufficiently uniform to build up a focal surface of SiPM arrays fulfilling the requirements for a telescope detecting photons in the UV range.

  13. Characterization and modeling of crosstalk and afterpulsing in Hamamatsu silicon photomultipliers

    International Nuclear Information System (INIS)

    Rosado, J.; Hidalgo, S.

    2015-01-01

    The crosstalk and afterpulsing in Hamamatsu silicon photomultipliers, called Multi-Pixel Photon Counters (MPPCs), have been studied in depth. Several components of the correlated noise have been identified according to their different possible causes and their effects on the signal. In particular, we have distinguished between prompt and delayed crosstalk as well as between trap-assisted and hole-induced afterpulsing. The prompt crosstalk has been characterized through the pulse amplitude spectrum measured at dark conditions. The newest MPPC series, which incorporate isolating trenches between pixels, exhibit a very low prompt crosstalk, but a small component remains likely due to secondary photons reflected on the top surface of the device and photon-generated minority carriers diffusing in the silicon substrate.We present a meticulous procedure to characterize the afterpulsing and delayed crosstalk through the amplitude and delay time distributions of secondary pulses. Our results indicate that both noise components are due to minority carriers diffusing in the substrate and that this effect is drastically reduced in the new MPPC series as a consequence of an increase of one order of magnitude in the doping density of the substrate.Finally, we have developed a Monte Carlo simulation to study the different components of the afterpulsing and crosstalk. The simulation results support our interpretation of the experimental data. They also demonstrate that trenches longer than those employed in the Hamamatsu MPPCs would reduce the crosstalk to a much greater extent

  14. Reduction of saliva-promoted adhesion of Streptococcus mutans MT8148 and dental biofilm development by tragacanth gum and yeast-derived phosphomannan.

    Science.gov (United States)

    Shimotoyodome, A; Kobayashi, H; Nakamura, J; Tokimitsu, I; Hase, T; Inoue, T; Matsukubo, T; Takaesu, Y

    2006-01-01

    The aim of this study was to investigate materials which reduce saliva-promoted adhesion of Streptococcus mutans onto enamel surfaces, and their potential in preventing dental biofilm development. The effects of hydroxyapatite (HA) surface pretreatment with hydrophilic polysaccharides on saliva-promoted S. mutans adhesion in vitro and de novo dental biofilm deposition in vivo were examined. Saliva-promoted adhesion of S. mutans MT8148 was significantly reduced by pretreatment of the HA surface with tragacanth gum (TG) and yeast-derived phosphoglycans. Extracellular phosphomannan (PM) from Pichia capsulata NRRL Y-1842 and TG reduced biofilm development on lower incisors in plaque-susceptible rats when administered via drinking water at concentrations of 0.5% and 0.01%, respectively. The inhibitory effect of TG on de novo dental biofilm formation was also demonstrated when administered via mouthwash in humans. It is concluded that TG and yeast-derived PM have the potential for use as anti-adherent agents and are effective in reducing de novo dental biofilm formation.

  15. A Highly Sensitive Multi-Element HgCdTe E-APD Detector for IPDA Lidar Applications

    Science.gov (United States)

    Beck, Jeff; Welch, Terry; Mitra, Pradip; Reiff, Kirk; Sun, Xiaoli; Abshire, James

    2014-01-01

    An HgCdTe electron avalanche photodiode (e-APD) detector has been developed for lidar receivers, one application of which is integrated path differential absorption lidar measurements of such atmospheric trace gases as CO2 and CH4. The HgCdTe APD has a wide, visible to mid-wave-infrared, spectral response, high dynamic range, substantially improved sensitivity, and an expected improvement in operational lifetime. A demonstration sensor-chip assembly consisting of a 4.3 lm cutoff HgCdTe 4 9 4 APD detector array with 80 micrometer pitch pixels and a custom complementary metal-oxide-semiconductor readout integrated circuit was developed. For one typical array the APD gain was 654 at 12 V with corresponding gain normalized dark currents ranging from 1.2 fA to 3.2 fA. The 4 9 4 detector system was characterized at 77 K with a 1.55 micrometer wavelength, 1 microsecond wide, laser pulse. The measured unit gain detector photon conversion efficiency was 91.1%. At 11 V bias the mean measured APD gain at 77 K was 307.8 with sigma/mean uniformity of 1.23%. The average, noise-bandwidth normalized, system noise-equivalent power (NEP) was 1.04 fW/Hz(exp 1/2) with a sigma/mean of 3.8%. The measured, electronics-limited, bandwidth of 6.8 MHz was more than adequate for 1 microsecond pulse detection. The system had an NEP (3 MHz) of 0.4 fW/Hz(exp 1/2) at 12 V APD bias and a linear dynamic range close to 1000. A gain-independent quantum-limited SNR of 80% of full theoretical was indicative of a gain-independent excess noise factor very close to 1.0 and the expected APD mode quantum efficiency.

  16. Study on APD real time compensation methods of laser Detection system

    International Nuclear Information System (INIS)

    Feng Ying; Zhang He; Zhang Xiangjin; Liu Kun

    2011-01-01

    With the monochromatic and the directional capability of the laser, laser detection system is confidential in anti-jamming. Detection accuracy is improved significantly as the result of laser's good orientation ability. Sensitivity is enhanced as laser's high-brightness characteristic. With the development of laser technology and laser devices, laser detections are developed both in civilian and military areas. In the military field, laser detection system has been widely applied in various types of tactical missiles, the technique is more mature. Because photo detectors receive the backscattering echo signal of target in laser detection system, they are required sensitive enough to weak signal. With APD's salient features of high sensitivity, rapid response speed, high response frequency and low noise equivalent power, etc.; PIN is replaced by APD to improve sensitivity of laser detection system in recent years. The signal magnification is inadequate in laser detection system, the detector output is usually amplified by multistage amplifiers. And then the system noise includes detector noise and latter amplifiers noise. With its high internal gain, APD becomes the primary noise source of receiving system. This point can be attested by analyzing the transfer function of laser detection system receiver. To ensure the system detecting ability, APD noise must be mitigated as low as possible. According to a large number of experiments, the power signal-to-noise (SNR) and the best multiplication factor of APD are mostly affected by background radiation and temperature. In order to make APD operate at state of the best multiplication factor, the optimum bias must be selected due to the actual operating circumstance. Therefore, APD realtime compensation must be adopted. The existing APD compensation includes the constant false alarm rate compensation, the noise compensation and the temperature compensation. The features of these compensations are obtained by analyzing

  17. Study on APD real time compensation methods of laser Detection system

    Science.gov (United States)

    Ying, Feng; He, Zhang; Xiangjin, Zhang; Kun, Liu

    2011-02-01

    With the monochromatic and the directional capability of the laser, laser detection system is confidential in anti-jamming. Detection accuracy is improved significantly as the result of laser's good orientation ability. Sensitivity is enhanced as laser's high-brightness characteristic. With the development of laser technology and laser devices, laser detections are developed both in civilian and military areas. In the military field, laser detection system has been widely applied in various types of tactical missiles, the technique is more mature. Because photo detectors receive the backscattering echo signal of target in laser detection system, they are required sensitive enough to weak signal. With APD's salient features of high sensitivity, rapid response speed, high response frequency and low noise equivalent power, etc.; PIN is replaced by APD to improve sensitivity of laser detection system in recent years. The signal magnification is inadequate in laser detection system, the detector output is usually amplified by multistage amplifiers. And then the system noise includes detector noise and latter amplifiers noise. With its high internal gain, APD becomes the primary noise source of receiving system. This point can be attested by analyzing the transfer function of laser detection system receiver. To ensure the system detecting ability, APD noise must be mitigated as low as possible. According to a large number of experiments, the power signal-to-noise (SNR) and the best multiplication factor of APD are mostly affected by background radiation and temperature. In order to make APD operate at state of the best multiplication factor, the optimum bias must be selected due to the actual operating circumstance. Therefore, APD realtime compensation must be adopted. The existing APD compensation includes the constant false alarm rate compensation, the noise compensation and the temperature compensation. The features of these compensations are obtained by analyzing

  18. Design and performance of single photon APD focal plane arrays for 3-D LADAR imaging

    Science.gov (United States)

    Itzler, Mark A.; Entwistle, Mark; Owens, Mark; Patel, Ketan; Jiang, Xudong; Slomkowski, Krystyna; Rangwala, Sabbir; Zalud, Peter F.; Senko, Tom; Tower, John; Ferraro, Joseph

    2010-08-01

    ×We describe the design, fabrication, and performance of focal plane arrays (FPAs) for use in 3-D LADAR imaging applications requiring single photon sensitivity. These 32 × 32 FPAs provide high-efficiency single photon sensitivity for three-dimensional LADAR imaging applications at 1064 nm. Our GmAPD arrays are designed using a planarpassivated avalanche photodiode device platform with buried p-n junctions that has demonstrated excellent performance uniformity, operational stability, and long-term reliability. The core of the FPA is a chip stack formed by hybridizing the GmAPD photodiode array to a custom CMOS read-out integrated circuit (ROIC) and attaching a precision-aligned GaP microlens array (MLA) to the back-illuminated detector array. Each ROIC pixel includes an active quenching circuit governing Geiger-mode operation of the corresponding avalanche photodiode pixel as well as a pseudo-random counter to capture per-pixel time-of-flight timestamps in each frame. The FPA has been designed to operate at frame rates as high as 186 kHz for 2 μs range gates. Effective single photon detection efficiencies as high as 40% (including all optical transmission and MLA losses) are achieved for dark count rates below 20 kHz. For these planar-geometry diffused-junction GmAPDs, isolation trenches are used to reduce crosstalk due to hot carrier luminescence effects during avalanche events, and we present details of the crosstalk performance for different operating conditions. Direct measurement of temporal probability distribution functions due to cumulative timing uncertainties of the GmAPDs and ROIC circuitry has demonstrated a FWHM timing jitter as low as 265 ps (standard deviation is ~100 ps).

  19. FACT-The first Cherenkov telescope using a G-APD camera for TeV gamma-ray astronomy

    International Nuclear Information System (INIS)

    Anderhub, H.; Backes, M.; Biland, A.; Boller, A.; Braun, I.; Bretz, T.; Commichau, S.; Commichau, V.; Domke, M.; Dorner, D.; Gendotti, A.; Grimm, O.; Gunten, H. von; Hildebrand, D.; Horisberger, U.; Koehne, J.-H.; Kraehenbuehl, T.; Kranich, D.; Krumm, B.; Lorenz, E.

    2011-01-01

    Geiger-mode Avalanche Photodiodes (G-APD) bear the potential to significantly improve the sensitivity of Imaging Air Cherenkov Telescopes (IACT). We are currently building the First G-APD Cherenkov Telescope (FACT) by refurbishing an old IACT with a mirror area of 9.5 square meters and are constructing a new, fine-pixelized camera using novel G-APDs. The main goal is to evaluate the performance of a complete system by observing very high energy gamma-rays from the Crab Nebula. This is an important field test to check the feasibility of G-APD-based cameras to replace at some time the PMT-based cameras of planned future IACTs like AGIS and CTA. In this article, we present the basic design of such a camera as well as some important details.

  20. Use of Fall-Risk Inducing Drugs in Patients Using Anti-Parkinson Drugs (APD: A Swedish Register-Based Study.

    Directory of Open Access Journals (Sweden)

    Ylva Haasum

    Full Text Available Many drugs increase the risk of falls in old age. Although persons with Parkinson's disease (PD are at increased risk of experiencing falls and fractures, the use of fall-risk inducing drugs (FRIDs in this population has not previously been investigated. The objective of this study was to investigate the burden of use of FRIDs in older persons treated with anti-Parkinson drugs (APD; used as a proxy for PD, compared to persons without APD.We analyzed individual data on age, sex, type of housing and drug use in 1 346 709 persons aged ≥ 65 years in the Swedish Prescribed Drug Register on the date of 30 September 2008. Main outcome measure was the use of FRIDs.FRIDs were used by 79% of persons with APD and 75% of persons without APD. Persons with APD were more likely to use ≥ 1 FRIDs compared to persons without APD (adjusted OR: 1.09; 95% CI: 1.06-1-12. The association was stronger for concomitant use of ≥ 5 FRIDS (adjusted OR: 1.49; 95% CI: 1.44-1.55.The high use of FRIDs among persons with APD indicates that these patients may be at increased risk of drug-induced falls. Further studies are needed to investigate how these drugs affect the risk of falling in persons with PD.

  1. Development of a 32-channel ASIC for an X-ray APD detector onboard the ISS

    Science.gov (United States)

    Arimoto, Makoto; Harita, Shohei; Sugita, Satoshi; Yatsu, Yoichi; Kawai, Nobuyuki; Ikeda, Hirokazu; Tomida, Hiroshi; Isobe, Naoki; Ueno, Shiro; Mihara, Tatehiro; Serino, Motoko; Kohmura, Takayoshi; Sakamoto, Takanori; Yoshida, Atsumasa; Tsunemi, Hiroshi; Hatori, Satoshi; Kume, Kyo; Hasegawa, Takashi

    2018-02-01

    We report on the design and performance of a mixed-signal application specific integrated circuit (ASIC) dedicated to avalanche photodiodes (APDs) in order to detect hard X-ray emissions in a wide energy band onboard the International Space Station. To realize wide-band detection from 20 keV to 1 MeV, we use Ce:GAGG scintillators, each coupled to an APD, with low-noise front-end electronics capable of achieving a minimum energy detection threshold of 20 keV. The developed ASIC has the ability to read out 32-channel APD signals using 0.35 μm CMOS technology, and an analog amplifier at the input stage is designed to suppress the capacitive noise primarily arising from the large detector capacitance of the APDs. The ASIC achieves a performance of 2099 e- + 1.5 e-/pF at root mean square (RMS) with a wide 300 fC dynamic range. Coupling a reverse-type APD with a Ce:GAGG scintillator, we obtain an energy resolution of 6.7% (FWHM) at 662 keV and a minimum detectable energy of 20 keV at room temperature (20 °C). Furthermore, we examine the radiation tolerance for space applications by using a 90 MeV proton beam, confirming that the ASIC is free of single-event effects and can operate properly without serious degradation in analog and digital processing.

  2. Improved wavelengths for the 1s2s3S1-1s2p3P0,2 transitions in helium-like Si12+

    International Nuclear Information System (INIS)

    Armour, I.A.; Myers, E.G.; Silver, J.D.; Traebert, E.; Oxford Univ.

    1979-01-01

    The wavelengths of the 1s2s 3 S 1 -1s2p 3 P 0 , 2 transitions in He-like Si 12+ have been remaesured to be 87.86 +- 0.01 nm and 81.48 +- 0.01 nm. The use of Rydberg lines for the calibration of fast beam spectra is discussed. (orig.)

  3. Characterization of 1600 Hamamatsu 16-anode photomultipliers for the MINOS Far detector

    International Nuclear Information System (INIS)

    Lang, K.; Day, J.; Eilerts, S.; Fuqua, S.; Guillen, A.; Kordosky, M.; Lang, M.; Liu, J.; Opaska, W.; Proga, M.; Vahle, P.; Winbow, A.; Drake, G.; Thomas, J.; Andreopoulos, C.; Saoulidou, N.; Stamoulis, P.; Tzanakos, G.; Zois, M.; Weber, A.; Michael, D.

    2005-01-01

    We are reporting results of the characterization of over 1600 multi-anode R5900-00-M16 photomultipliers manufactured by Hamamatsu Photonics K.K., and installed in the MINOS Far detector. We have conducted extensive tests of the uniformity of gain and collection efficiency of individual anodes, the cross-talk among all 16 channels, the dark noise, and the linearity of response. In our studies we used a blue light-emitting diode to illuminate phototubes through 1.2 mm diameter optical fibers. In this paper, we present summaries of the main characteristics of the tested photomultipliers

  4. Characterization and quality control of avalanche photodiode arrays for the Clear-PEM detector modules

    International Nuclear Information System (INIS)

    Abreu, Conceicao; Amaral, Pedro; Carrico, Bruno; Ferreira, Miguel; Luyten, Joan; Moura, Rui; Ortigao, Catarina; Rato, Pedro; Varela, Joao

    2007-01-01

    Clear-PEM is a Positron Emission Mammography (PEM) prototype being developed in the framework of the Crystal Clear Collaboration at CERN. This device is a dedicated PET camera for mammography, based on LYSO:Ce scintillator crystals, Avalanche PhotoDiodes (APD) and a fast, low-noise electronics readout system, designed to examine both the breast and the axillary lymph node areas, and aiming at the detection of tumors down to 2 mm in diameter. The prototype has two planar detector heads, each composed of 96 detector modules. The Clear-PEM detector module is composed of a matrix of 32 identical 2x2x20 mm 3 LYSO:Ce crystals read at both ends by Hamamatsu S8550 APD arrays (4x8) for Depth-of-Interaction (DoI) capability. The APD arrays were characterized by the measurement of gain and dark current as a function of bias voltage, under controlled temperature conditions. Two independent setups were used. The full set of 398 APD arrays followed a well-defined quality control (QC) protocol, aiming at the rejection of arrays not complying within defined specifications. From a total of 398 arrays, only 2 (0.5%) were rejected, reassuring the trust in these detectors for prototype assembly and future developments

  5. Ultraviolet Light Curves of Gaia16apd in Superluminous Supernova Models

    Energy Technology Data Exchange (ETDEWEB)

    Tolstov, Alexey; Zhiglo, Andrey; Nomoto, Ken’ichi; Blinnikov, Sergei [Kavli Institute for the Physics and Mathematics of the Universe (WPI), The University of Tokyo Institutes for Advanced Study, The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8583 (Japan); Sorokina, Elena [Sternberg Astronomical Institute, M.V.Lomonosov Moscow State University, 119234 Moscow (Russian Federation); Kozyreva, Alexandra, E-mail: alexey.tolstov@ipmu.jp [The Raymond and Beverly Sackler School of Physics and Astronomy, Tel Aviv University, Tel Aviv 69978 (Israel)

    2017-08-10

    Observations of Gaia16apd revealed extremely luminous ultraviolet emission among superluminous supernovae (SLSNe). Using radiation hydrodynamics simulations, we perform a comparison of UV light curves, color temperatures, and photospheric velocities between the most popular SLSN models: pair-instability supernova, magnetar, and interaction with circumstellar medium. We find that the interaction model is the most promising to explain the extreme UV luminosity of Gaia16apd. The differences in late-time UV emission and in color evolution found between the models can be used to link an observed SLSN event to the most appropriate model. Observations at UV wavelengths can be used to clarify the nature of SLSNe and more attention should be paid to them in future follow-up observations.

  6. A Novel Time-Based Readout Scheme for a Combined PET-CT Detector Using APDs

    CERN Document Server

    Powolny, F; Hillemanns, H; Jarron, P; Lecoq, P; Meyer, T C; Moraes, D

    2008-01-01

    This paper summarizes CERN R&D work done in the framework of the European Commission's FP6 BioCare Project. The objective was to develop a novel "time-based" signal processing technique to read out LSO-APD photodetectors for medical imaging. An important aspect was to employ the technique in a combined scenario for both computer tomography (CT) and positron emission tomography (PET) with effectively no tradeoffs in efficiency and resolution compared to traditional single mode machines. This made the use of low noise and yet very high-speed monolithic front-end electronics essential so as to assure the required timing characteristics together with a high signal-to-noise ratio. Using APDs for photon detection, two chips, traditionally employed for particle physics, could be identified to meet the above criteria. Although both were not optimized for their intended new medical application, excellent performance in conjunction with LSO-APD sensors could be derived. Whereas a measured energy resolution of 16% (...

  7. Electronics for the camera of the First G-APD Cherenkov Telescope (FACT) for ground based gamma-ray astronomy

    International Nuclear Information System (INIS)

    Anderhub, H; Biland, A; Boller, A; Braun, I; Commichau, V; Djambazov, L; Dorner, D; Gendotti, A; Grimm, O; Gunten, H P von; Hildebrand, D; Horisberger, U; Huber, B; Kim, K-S; Krähenbühl, T; Backes, M; Köhne, J-H; Krumm, B; Bretz, T; Farnier, C

    2012-01-01

    Within the FACT project, we construct a new type of camera based on Geiger-mode avalanche photodiodes (G-APDs). Compared to photomultipliers, G-APDs are more robust, need a lower operation voltage and have the potential of higher photon-detection efficiency and lower cost, but were never fully tested in the harsh environments of Cherenkov telescopes. The FACT camera consists of 1440 G-APD pixels and readout channels, based on the DRS4 (Domino Ring Sampler) analog pipeline chip and commercial Ethernet components. Preamplifiers, trigger system, digitization, slow control and power converters are integrated into the camera.

  8. The New APD Based Readout for the Crystal Barrel Calorimeter

    International Nuclear Information System (INIS)

    Urban, M; Honisch, Ch; Steinacher, M

    2015-01-01

    The CBELSA/TAPS experiment at ELSA measures double polarization observables in meson photoproduction off protons and neutrons. To be able to measure purely neutral reactions off polarized neutrons with high efficiency, the main calorimeter has to be integrated into the first level trigger. This requires to exchange the existing PIN photo diode by a new avalanche photo diode (APD) readout. The newly developed readout electronics will provide an energy resolution compatible to the previous set-up and a fast trigger signal down to 10 MeV energy deposit per crystal. After the successful final tests with a 3x3 CsI crystal matrix in Bonn at ELSA and in Mainz at MAMI all front-end electronics were produced in fall 2013. Automated test routines for the front-end electronics were developed and the characterization measurements of all APDs were successfully accomplished in Bonn. The project is supported by the Deutsche Forschungsgemeinschaft (SFB/TR16) and Schweizerischer Nationalfonds

  9. Geiger-mode APD camera system for single-photon 3D LADAR imaging

    Science.gov (United States)

    Entwistle, Mark; Itzler, Mark A.; Chen, Jim; Owens, Mark; Patel, Ketan; Jiang, Xudong; Slomkowski, Krystyna; Rangwala, Sabbir

    2012-06-01

    The unparalleled sensitivity of 3D LADAR imaging sensors based on single photon detection provides substantial benefits for imaging at long stand-off distances and minimizing laser pulse energy requirements. To obtain 3D LADAR images with single photon sensitivity, we have demonstrated focal plane arrays (FPAs) based on InGaAsP Geiger-mode avalanche photodiodes (GmAPDs) optimized for use at either 1.06 μm or 1.55 μm. These state-of-the-art FPAs exhibit excellent pixel-level performance and the capability for 100% pixel yield on a 32 x 32 format. To realize the full potential of these FPAs, we have recently developed an integrated camera system providing turnkey operation based on FPGA control. This system implementation enables the extremely high frame-rate capability of the GmAPD FPA, and frame rates in excess of 250 kHz (for 0.4 μs range gates) can be accommodated using an industry-standard CameraLink interface in full configuration. Real-time data streaming for continuous acquisition of 2 μs range gate point cloud data with 13-bit time-stamp resolution at 186 kHz frame rates has been established using multiple solid-state storage drives. Range gate durations spanning 4 ns to 10 μs provide broad operational flexibility. The camera also provides real-time signal processing in the form of multi-frame gray-scale contrast images and single-frame time-stamp histograms, and automated bias control has been implemented to maintain a constant photon detection efficiency in the presence of ambient temperature changes. A comprehensive graphical user interface has been developed to provide complete camera control using a simple serial command set, and this command set supports highly flexible end-user customization.

  10. Penyusunan Perencanaan Keberlangsungan Bisnis PT PLN (Persero APD Jateng dan DIY dengan ISO 22301 dan Metode OCTAVE

    Directory of Open Access Journals (Sweden)

    Azmi Afifah Zahra

    2017-01-01

    Full Text Available Abstrak— Penelitian dalam tugas akhir ini adalah melakukan penyusunan perencanaan keberlangsungan bisnis teknologi informasi pada PT PLN (Persero APD Jateng dan DIY dengan berbasis risiko sebagai bentuk kesiapan perusahaan dalam menangani risiko dan dampak bisnis yang mengancam perusahaan. PT PLN (Persero APD Jateng dan DIY menggunakan sistem dan layanan TI sebagai daya dukung perusahaan dalam mencapai tujuannya. Penggunaan sistem dan layanan TI tersebut tidak terlepas dari adanya ancaman pada risiko sistem dan layanan TI serta dampak dari proses bisnis yang dijalankan oleh tiap fungsi bisnis perusahaan. Dalam proses penyusunan untuk perencanaan keberlangsungan bisnis akan dibuat terlebih dahulu alur kerja untuk kegiatan pengelolaan keberlangsungan bisnis (Business Continuity Management untuk PT PLN (Persero APD Jateng dan DIY dengan menggunakan acuan ISO 22301: 2012 dan alur kerja yang telah diterapkan oleh perusahaan lain yaitu dari Perusahaan Chubu Electric Power Company Group dan DHS Electricity dengan tetap memberikan prosedur praktis yang dapat disesuaikan oleh PT PLN (Persero APD Jateng dan DIY. Hasil akhir dari penelitian ini adalah berupa rekomendasi penerapan alur kerja dan strategi keberlangsungan bisnis untuk PT PLN (Persero berdasarkan pada risiko aset TI yang menjadi tanggung jawab tim SCADA dan Telekomunikasi.

  11. A high granularity plastic scintillator tile hadronic calorimeter with APD readout for a linear collider detector

    Czech Academy of Sciences Publication Activity Database

    Andreev, V.; Cvach, Jaroslav; Danilov, M.; Devitsin, E.; Dodonov, V.; Eigen, G.; Garutti, E.; Gilitzky, Yu.; Groll, M.; Heuer, R.D.; Janata, Milan; Kacl, Ivan; Korbel, V.; Kozlov, V. Yu; Meyer, H.; Morgunov, V.; Němeček, Stanislav; Pöschl, R.; Polák, Ivo; Raspereza, A.; Reiche, S.; Rusinov, V.; Sefkow, F.; Smirnov, P.; Terkulov, A.; Valkár, Š.; Weichert, Jan; Zálešák, Jaroslav

    2006-01-01

    Roč. 564, - (2006), s. 144-154 ISSN 0168-9002 R&D Projects: GA MŠk(CZ) LC527; GA MŠk(CZ) 1P05LA259; GA ČR(CZ) GA202/05/0653 Institutional research plan: CEZ:AV0Z10100502 Keywords : hadronic calorimeter * plastic scintillator tile * APD readout * linear collider detector Subject RIV: BF - Elementary Particles and High Energy Physics Impact factor: 1.185, year: 2006

  12. Experimental characterization of the Clear-PEM scanner spectrometric performance

    Energy Technology Data Exchange (ETDEWEB)

    Bugalho, R; Carrico, B; Ferreira, C S; Frade, M; Ferreira, M; Moura, R; Ortigao, C; Pinheiro, J F; Rodrigues, P; Rolo, I; Silva, J C; Trindade, A; Varela, J [Laboratorio de Instrumentacao e Fisica Experimental de Particulas (LIP), Av. Elias Garcia 14-1, 1000-149 Lisboa (Portugal)], E-mail: frade@lip.pt

    2009-10-15

    In the framework of the Clear-PEM project for the construction of a high-resolution and high-specificity scanner for breast cancer imaging, a Positron Emission Mammography tomograph has been developed and installed at the Instituto Portugues de Oncologia do Porto hospital. The Clear-PEM scanner is mainly composed by two planar detector heads attached to a robotic arm, trigger/data acquisition electronics system and computing servers. The detector heads hold crystal matrices built from 2 x 2 x 20 mm{sup 3} LYSO:Ce crystals readout by Hamamatsu S8550 APD arrays. The APDs are optically coupled to both ends of the 6144 crystals in order to extract the DOI information for each detected event. Each one of 12288 APD's pixels is read and controlled by Application Specific Integrated Circuits water-cooled by an external cooling unit. The Clear-PEM frontend boards innovative design results in a unprecedented integration of the crystal matrices, APDs and ASICs, making Clear-PEM the PET scanner with the highest number of APD pixels ever integrated so far. In this paper, the scanner's main technical characteristics, calibration strategies and the first spectrometric performance evaluation in a clinical environment are presented. The first commissioning results show 99.7% active channels, which, after calibration, have inter-pixel and absolute gain distributions with dispersions of, respectively, 12.2% and 15.3%, demonstrating that despite the large number of channels, the system is uniform. The mean energy resolution at 511 keV is of 15.9%, with a 8.8% dispersion, and the mean C{sub DOI}{sup -1} is 5.9%/mm, with a 7.8% dispersion. The coincidence time resolution, at 511 keV, for a energy window between 400 and 600 keV, is 5.2 ns FWHM.

  13. A Time-Based Front End Readout System for PET & CT

    CERN Document Server

    Meyer, T C; Anghinolfi, F; Auffray, E; Dosanjh, M; Hillemanns, H; Hoffmann, H -F; Jarron, P; Kaplon, J; Kronberger, M; Lecoq, P; Moraes, D; Trummer, J

    2007-01-01

    In the framework of the European FP6's BioCare project, we develop a novel, time-based, photo-detector readout technique to increase sensitivity and timing precision for molecular imaging in PET and CT. The project aims to employ Avalanche Photo Diode (APD) arrays with state of the art, high speed, front end amplifiers and discrimination circuits developed for the Large Hadron Collider (LHC) physics program at CERN, suitable to detect and process photons in a combined one-unit PET/CT detection head. In the so-called time-based approach our efforts focus on the system's timing performance with sub-nanosecond time-jitter and -walk, and yet also provide information on photon energy without resorting to analog to digital conversion. The bandwidth of the electronic circuitry is compatible with the scintillator's intrinsic light response (e.g. les40ns in LSO) and hence allows high rate CT operation in single-photon counting mode. Based on commercial LSO crystals and Hamamatsu S8550 APD arrays, we show the system pe...

  14. Predictors of Percutaneous Catheter Drainage (PCD) after Abdominal Paracentesis Drainage (APD) in Patients with Moderately Severe or Severe Acute Pancreatitis along with Fluid Collections

    Science.gov (United States)

    Liu, Wei-hui; Wang, Tao; Yan, Hong-tao; Chen, Tao; Xu, Chuan; Ye, Ping; Zhang, Ning; Liu, Zheng-cai; Tang, Li-jun

    2015-01-01

    Aims Although we previously demonstrated abdominal paracentesis drainage (APD) preceding percutaneous catheter drainage (PCD) as the central step for treating patients with moderately severe (MSAP) or severe acute pancreatitis (SAP), the predictors leading to PCD after APD have not been studied. Methods Consecutive patients with MSAP or SAP were recruited between June 2011 and June 2013. As a step-up approach, all patients initially received medical management, later underwent ultrasound-guided APD before PCD, if necessary, followed by endoscopic necrosectomy through the path formed by PCD. APD primarily targeted fluid in the abdominal or pelvic cavities, whereas PCD aimed at (peri)pancreatic fluid. Results Of the 92 enrolled patients, 40 were managed with APD alone and 52 received PCD after APD (14 required necrosectomy after initial PCD). The overall mortality was 6.5%. Univariate analysis showed that among the 20 selected parameters, 13 factors significantly affected PCD intervention after APD. Multivariate analysis revealed that infected (peri)pancreatic collections (P = -0.001), maximum extent of necrosis of more than 30% of the pancreas (P = -0.024), size of the largest necrotic peri(pancreatic) collection (P = -0.007), and reduction of (peri)pancreatic fluid collections by collections, a largest necrotic peri(pancreatic) collection of more than 100 ml, and reduction of (peri)pancreatic fluid collections by <50% after APD could effectively predict the need for PCD in the early course of the disease. PMID:25659143

  15. Characterization of the Hamamatsu 8" R5912-MOD Photomultiplier tube

    Science.gov (United States)

    Kaptanoglu, Tanner

    2018-05-01

    Current and future neutrino and direct detection dark matter experiments hope to take advantage of improving technologies in photon detection. Many of these detectors are large, monolithic optical detectors that use relatively low-cost, large-area, and efficient photomultiplier tubes (PMTs). A candidate PMT for future experiments is a newly developed prototype Hamamatsu PMT, the R5912-MOD. In this paper we describe measurements made of the single photoelectron time and charge response of the R5912-MOD, as well as detail some direct comparisons to similar PMTs. Most of these measurements were performed on three R5912-MOD PMTs operating at gains close to 1 × 107. The transit time spread (σ) and the charge peak-to-valley were measured to be on average 680ps and 4.2 respectively. The results of this paper show the R5912-MOD is an excellent candidate for future experiments in several regards, particularly due to its narrow spread in timing.

  16. FACT - Status and experience from five years of operation of the first G-APD Cherenkov Telescope

    Science.gov (United States)

    Neise, D.; Adam, J.; Ahnen, M. L.; Baack, D.; Balbo, M.; Bergmann, M.; Biland, A.; Blank, M.; Bretz, T.; Brügge, K. A.; Buss, J.; Dmytriiev, A.; Dorner, D.; Einecke, S.; Hempfling, C.; Hildebrand, D.; Hughes, G.; Linhoff, L.; Mannheim, K.; Müller, S.; Neronov, A.; Nöthe, M.; Paravac, A.; Pauss, F.; Rhode, W.; Shukla, A.; Temme, F.; Thaele, J.; Walter, R.

    2017-12-01

    The First G-APD Cherenkov Telescope (FACT) demonstrates the usability of novel Geiger-mode operated Avalanche Photo Diodes (G-APD, often called SiPM) for Imaging Atmospheric Cherenkov Telescopes (IACT). The camera consists of 1440 pixels with dedicated electronics operating at 2 Giga samples per second. It is installed on the refurbished HEGRA telescope with a mirror area of ≈ 9.5m2 on the Canary Island La Palma. FACT is taking data almost every night since the camera was installed in October 2011. It was possible to improve the data taking efficiency to very high values due to the very stable and reliable operation. This also allows to operate FACT remotely without any need for operators on site. Even remote human intervention became less and less frequent over the years, allowing operation to become mostly automatic. FACT is monitoring the long-term behavior of some very-high energy variable extra-galactic sources with unparalleled sampling density as well as testing the behavior of the sensors under severe weather conditions. Due to the long exposure of FACT's G-APDs under strong moonlight conditions it was possible to evaluate the aging effects of G-APDs due to collected charge. No indication of aging was found. No external calibration device is needed to operate FACT since the properties of the sensors themselves allow for a high precision self-calibration of the camera.

  17. New method for evaluating effective recovery time and single photoelectron response in silicon photomultipliers

    Energy Technology Data Exchange (ETDEWEB)

    Grodzicka, Martyna, E-mail: m.grodzicka@ncbj.gov.pl; Szczęśniak, Tomasz; Moszyński, Marek; Szawłowski, Marek; Grodzicki, Krystian

    2015-05-21

    The linearity of a silicon photomultiplier (SiPM) response depends on the number of APD cells and its effective recovery time and it is related to the intensity and duration of the detected light pulses. The aim of this study was to determine the effective recovery time on the basis of the measured SiPM response to light pulses of different durations. A closer analysis of the SiPM response to the light pulses shorter than the effective recovery time of APD cells led to a method for the evaluation of the single photoelectron response of the devices where the single photoelectron peak cannot be clearly measured. This is necessary in the evaluation of the number of fired APD cells (or the number of photoelectrons) in measurements with light pulses of various durations. Measurements were done with SiPMs manufactured by two companies: Hamamatsu and SensL.

  18. Novel method of using 99mTc-APD (pamidronate) to monitor delivery of bisphosphonates to bone without renal burden

    International Nuclear Information System (INIS)

    Kumar, V.; Wong, E.; Kumar, D.; Howman-Giles, R.; Little, D.G.

    2004-01-01

    Purpose: Bisphosphonates (BP) were first used in the 1960's when their ability to bind to bone mineral hydroxyapatite made them a useful tool for studying orthopaedic bone repair processes. From being an experimental agent, now BP have become the treatment of choice for clinical disorders associated with increased bone resorption, such as osteoporosis, myeloma and bone metastasis. While the effectiveness of BP in managing these disorders is commendable, they have certain undesirable side effects. For example, intravenous injection of Pamidronate may be associated with nephrocalcinosis of the kidneys. Therefore there is a need to develop a novel technique to demonstrate the localisation of the compound, which can be visualized within hours of administering into the patients. The Objective of the study is to develop 99mTc-labelled APD (Pamidronate) as a new tool and monitor its biodistribution by gamma imaging modality. This approach has not been reported elsewhere in the literature and has the potential to improve the quality of treatment currently available. Methods: Pamidronate (APD) was labelled with 99mTc-pertechnetate in the presence of Stannous Chloride as the reducing agent. The radiochemical purity (RCP) of the compound was determined by ITLC-SG/Acetone and found to be >99%. Rats were injected with 99mTc-APD intravenously (IV) subcutaneously (SC) and by direct application (Local) on surgically exposed femur. The animals were sacrificed at 2hr or 24hr post-injection and various organs were harvested and counted for radioactivity with a view to establish the biodistribution of 99mTc-APD. Results: 99mTc-APD was injected by three different modes as indicated in the Methods section. Planar and SPECT images were obtained at 2 hr and 24 hr post-injection. Intravenous injection (IV): When 99mTc-APD was administered IV, the labelled compound appeared instantly in the blood pool. The 2 hr and 24 hr images clearly showed that the labelled compound accumulated

  19. Time over threshold based multi-channel LuAG-APD PET detector

    International Nuclear Information System (INIS)

    Shimazoe, Kenji; Orita, Tadashi; Nakamura, Yasuaki; Takahashi, Hiroyuki

    2013-01-01

    To achieve efficient signal processing, several time-based positron emission tomography (PET) systems using a large number of granulated gamma-ray detectors have recently been proposed. In this work described here, a 144-channel Pr:LuAG avalanche photodiode (APD) PET detector that uses time over threshold (ToT) and pulse train methods was designed and fabricated. The detector is composed of 12×12 Pr:LuAG crystals, each of which produces a 2 mm×2 mm×10 mm pixel individually coupled to a 12×12 APD array, which in turn is connected pixel-by-pixel with one channel of a time over threshold based application-specific integrated circuit (ToT-ASIC) that was designed and fabricated using a 0.25 μm 3.3 V Taiwan Semiconductor Company complementary metal oxide semiconductor (TSMC CMOS) process. The ToT outputs are connected through a field-programmable gate array (FPGA) to a data acquisition (DAQ) system. Three front-end ASIC boards—each incorporating a ToT-ASIC chip, threshold control digital-to-analog converters (DACs), and connectors, and dissipating power at about 230 mW per board—are used to read from the 144-channel LuAG-APD detector. All three boards are connected through an FPGA board that is programmed to calibrate the individual thresholds of the ToT circuits to allow digital multiplexing to form an integrated PET module with a measured timing resolution of 4.2 ns. Images transmitted by this PET system can be successfully acquired through collimation masks. As a further implementation of this technology, an animal PET system consisting of eight gamma pixel modules forming a ring is planned

  20. High spatial resolution gamma imaging detector based on a 5 inch diameter R3292 Hamamatsu PSPMT

    International Nuclear Information System (INIS)

    Wojcik, R.; Majewski, S.; Kross, B.; Weisenberger, A.G.; Steinbach, D.

    1998-01-01

    High resolution imaging gamma-ray detectors were developed using Hamamatsu's 5 inch diameter R3292 position sensitive PMT (PSPMT) and a variety of crystal scintillator arrays. Special readout techniques were used to maximize the active imaging area while reducing the number of readout channels. Spatial resolutions approaching 1 mm were obtained in a broad energy range from 20 to 511 keV. Results are also presented of coupling the scintillator arrays to the PMT via imaging light guides consisting of acrylic optical fibers

  1. Complete tests of 2000 Hamamatsu R7525HA phototubes for the CMS-HF Forward Calorimeter

    International Nuclear Information System (INIS)

    Akgun, U.; Ayan, A.S.; Bruecken, P.; Duru, F.; Guelmez, E.; Mestvirishvilli, A.; Miller, M.; Olson, J.; Onel, Y.; Schmidt, I.

    2005-01-01

    Approximately 2000 PMTs will be used to detect the Cherenkov light generated in quartz fibers embedded in the CMS-HF Forward Calorimeter. The Hamamatsu R7525HA PMT was chosen for this purpose. We measured the transit time, transit time spread, pulse width, rise time, anode dark current, and relative gain for each tube in the test station at University of Iowa. Life-time, gain versus high voltage, and single photoelectron spectrum measurements were also done on a small sample of PMTs. All the tubes were tested to verify that they conform to the HF requirements

  2. Study and realization of pixelated APD Geiger photodetectors of very high sensitivity for Very High Energy gamma astronomy

    International Nuclear Information System (INIS)

    Jradi, K.

    2010-07-01

    Very High Energy gamma ray astronomy uses till now exclusively as detector the Photomultiplier Tube (PMT) to collect weak light flux of atmospheric showers. But an alternative is now emerging: Avalanche Photodiodes polarized in Geiger mode called 'Geiger-APD'. The PMT is a detector designed in the 70's which presents many advantages but also suffers from several drawbacks: size, weight, cost, sensitivity to magnetic field but especially difficulty to realize its pixelation in matrix. Geiger-APDs are semi-conductor devices made of PN junction integrated in a special technology to detect very low light flux, thanks to the polarization beyond the avalanche voltage. Geiger-APD presents very high photoelectron gain (∼106) strongly dependant on the polarization voltage beyond avalanche. These photodiodes present many advantages with respect to PMT, mainly as concerns miniaturization for applications based on imaging, such as the detection of Cerenkov flashes in gamma ray astronomy. In this thesis, we present the study, the design and the realization of a technological structure, based on Silicon. This structure has shown reliability to detect weak luminous flux with breakdown voltage at 12 V and dark current below 10 pA at breakdown. We also developed several models, physical and electrical, necessary to the technological optimization, as well to the development of control and readout circuits, i.e. the basis of any imaging technology. The work presented here consists in the study, the design and the realization of a matrix of high sensitivity pixels. A project of a Cerenkov telescope based on this innovative technology is also presented. (author)

  3. Sci-Sat AM(1): Imaging-08: Small animal APD PET detector with submillimetric resolution for molecular imaging.

    Science.gov (United States)

    Bérard, P; Bergeron, M; Pepin, C M; Cadorette, J; Tétrault, M-A; Viscogliosi, N; Fontaine, R; Dautet, H; Davies, M; Lecomte, R

    2008-07-01

    Visualization and quantification of biological processes in mice, the preferred animal model in most preclinical studies, require the best possible spatial resolution in positron emission tomography (PET). A new 64-channel avalanche photodiode (APD) detector module was developed to achieve submillimeter spatial resolution for this purpose. The module consists of dual 4 × 8 APD arrays mounted in a custom ceramic holder. Individual APD pixels having an active area of 1.1 × 1.1 mm2 at a 1.2 mm pitch can be fitted to an 8 × 8 LYSO scintillator block designed to accommodate one-to-one coupling. An analog test board with four 16-channel preamplifier ASICs was designed to be interfaced with the existing LabPET digital processing electronics. At a standard APD operating bias, a mean energy resolution of 27.5 ± 0.6% was typically obtained at 511 keV with a relative standard deviation of 13.8% in signal amplitude for the 64 individual pixels. Crosstalk between pixels was found to be well below the typical lower energy threshold used for PET imaging applications. With two modules in coincidence, a global timing resolution of 5.0 ns FWHM was measured. Finally, an intrinsic spatial resolution of 0.8 mm FWHM was measured by sweeping a 22Na point source between two detector arrays. The proposed detector module demonstrates promising characteristics for dedicated mouse PET imaging at submillimiter resolution. © 2008 American Association of Physicists in Medicine.

  4. The HADES-RICH upgrade using Hamamatsu H12700 MAPMTs with DiRICH FEE + Readout

    Science.gov (United States)

    Patel, V.; Traxler, M.

    2018-03-01

    The High Acceptance Di-Electron Spectrometer (HADES) is operational since the year 2000 and uses a hadron blind RICH detector for electron identification. The RICH photon detector is currently replaced by Hamamatsu H12700 MAPMTs with a readout system based on the DiRICH front-end module. The electronic readout chain is being developed as a joint effort of the HADES-, CBM- and PANDA collaborations and will also be used in the photon detectors for the upcoming Compressed Baryonic Matter (CBM) and PANDA experiments at FAIR . This article gives a brief overview on the photomultipliers and their quality assurance test measurements, as well as first measurements of the new DiRICH front-end module in final configurations.

  5. Performance Analysis of OCDMA Based on AND Detection in FTTH Access Network Using PIN & APD Photodiodes

    Science.gov (United States)

    Aldouri, Muthana; Aljunid, S. A.; Ahmad, R. Badlishah; Fadhil, Hilal A.

    2011-06-01

    In order to comprise between PIN photo detector and avalanche photodiodes in a system used double weight (DW) code to be a performance of the optical spectrum CDMA in FTTH network with point-to-multi-point (P2MP) application. The performance of PIN against APD is compared through simulation by using opt system software version 7. In this paper we used two networks designed as follows one used PIN photo detector and the second using APD photo diode, both two system using with and without erbium doped fiber amplifier (EDFA). It is found that APD photo diode in this system is better than PIN photo detector for all simulation results. The conversion used a Mach-Zehnder interferometer (MZI) wavelength converter. Also we are study, the proposing a detection scheme known as AND subtraction detection technique implemented with fiber Bragg Grating (FBG) act as encoder and decoder. This FBG is used to encode and decode the spectral amplitude coding namely double weight (DW) code in Optical Code Division Multiple Access (OCDMA). The performances are characterized through bit error rate (BER) and bit rate (BR) also the received power at various bit rate.

  6. Characterization of the aging and excess noise of a Hamamatsu fine mesh photopentode

    Energy Technology Data Exchange (ETDEWEB)

    Fujimoto, D., E-mail: fujimoto@phas.ubc.ca; Hearty, C., E-mail: hearty@physics.ubc.ca

    2016-07-01

    The excess noise factor and the aging characteristics of 16 Hamamatsu R11283 photopentodes have been tested. These fine-mesh phototubes are to be paired with pure CsI scintillation crystals considered for use in the endcap calorimeter of the Belle II detector. The average excess noise factor was found to be 1.9±0.1±0.4. The electronic noise of a custom preamplifier produced by the University of Montreal was found as a consequence of this measurement and was 1730±33 electrons, in agreement with previous values. On average, the gain×quantum efficiency was reduced to 92±3% of the initial value after passing an average of 7 C through the anode. This corresponds to 70 years of standard Belle II operation.

  7. Detection of Photons Generated in PWO Scintillator Crystals

    CERN Document Server

    Baccaro, Stefania; Cavallari, Francesca; Dafinei, Ioan; Diemoz, Marcella; Festinesi, Armando; Longo, Egidio; Montecchi, Marco; Organtini, Giovanni; Piegari, A

    1998-01-01

    This work deals with the optical characterization of the surface of EG&G and Hamamatsu APD's and performance of an antireflection coating made of Y2O3 and deposited on a PWO test piece. The effectiveness of antireflection treatments of PWO and Si surfaces is evaluated in a simplified and a realistic situation by means of the ratio of "detected to emitted photons". The complex refractive index of the Dow Corning 02-3067 optical grease is also reported.

  8. Current 2-μm dial measurements of atmospheric CO2 and expected results from space using new MCT APDS

    Science.gov (United States)

    Dumas, A.; Gibert, F.; Rothman, J.; Édouart, D.; Le Mounier, F.; Cénac, C.

    2017-11-01

    In the framework of CO2 monitoring in the Atmospheric Boundary Layer (ABL), a ground-based 2-μm Differential Absorption Lidar (DIAL) has been developed at the Laboratoire de Météorologie Dynamique (LMD) in Palaiseau. In order to derive flux information, this system has been set up with coherent detection, which allows to combine CO2 density measurements with wind velocity measurements. On the other hand, new advances in the field of Mercury Cadmium Tellure (MCT) Avalanche Photodiodes (APDs) open the way for high-precision measurements in direct detection ultimately from space. In this study, we first report on state of the art measurements obtained with the current coherent DIAL system before presenting expected results for a similar laser transmitter equipped with MCT APDs. For this latter part, we use a numerical model which relies on APDs performance data provided by the Laboratoire d'Électronique et de Technologie de l'Information (LETI).

  9. Kepatuhan Menggunakan Alat Pelindung Diri (APD Ditinjau dari Pengetahuan dan Perilaku pada Petugas Instalasi Pemeliharaan Sarana Dan Prasarana Rumah Sakit (IPSRS.

    Directory of Open Access Journals (Sweden)

    Rizka Ayu Zahara

    2017-12-01

    Full Text Available Abstrak: Alat Pelindung Diri (APD berfungsi untuk melindungi tubuh terhadap bahaya-bahaya kecelakaan kerja dan mengurangi tingkat keparahan dari kecelakaan kerja yang terjadi. Penelitian ini bertujuan untuk mengetahui korelasi antara pengetahuan dan perilaku petugas Instalasi Pemeliharaan Sarana dan Prasarana Rumah Sakit (IPSRS dengan kepatuhan terhadap penggunaan Alat Pelindung Diri (APD. Desain penelitian ini adalah Cross Sectional. Populasi adalah seluruh petugas IPSRS di RSUD Siti Aisyah Kota Lubuklinggau sebanyak 64 orang. Penelitian dilaksanakan pada bulan Agustus 2017. Analisis data menggunakan uji statistik chi-Square. Hasil penelitian menunjukkan adanya korelasi antara kepatuhan menggunakan Alat Pelindung Diri APD pengetahuan (p value = 0, 001, dan perilaku (p value = 0, 006. Pihak RSUD diharapkan dapat menerapkan Standar Prosedur Operasional (SPO yang lebih tegas, melakukan pelatihan tentang penggunaan APD, dan meningkatkan pengawasan terhadap kepatuhan petugas dalam menggunakan APD. Kata Kunci : Pengetahuan, Perilaku, Kepatuhan Alat Pelindung Diri (APD. ADHERENCE USING PERSONAL PROTECTIVE EQUIPMENT (PPE IN TERMS OF THE KNOWLEDGE AND BEHAVIOR OF OFFICER INSTALLATION MAINTENANCE FACILITIES AND INFRASTRUCTURE HOSPITAL (IPSRS Abstract: Personal Protective Equipment (PPE serves to protect the body against occupational injuries and reduce the severity of work accidents that occur. This study aims to determine the correlation between the knowledge and behavior of the officer of the Installation of Hospital Facilities and Infrastructure Maintenance (IPSRS with the adherence to the use of Personal Protective Equipment (PPE. The design of this study was Cross Sectional. The population is all IPSRS officers in RSUD Siti Aisyah Lubuklinggau City as many as 64 people. The study was conducted in August 2017. The data analysis used chi-square statistical test. The results showed that there was a correlation between adherence using Personal

  10. Simulation of Silicon Photomultiplier Signals

    Science.gov (United States)

    Seifert, Stefan; van Dam, Herman T.; Huizenga, Jan; Vinke, Ruud; Dendooven, Peter; Lohner, Herbert; Schaart, Dennis R.

    2009-12-01

    In a silicon photomultiplier (SiPM), also referred to as multi-pixel photon counter (MPPC), many Geiger-mode avalanche photodiodes (GM-APDs) are connected in parallel so as to combine the photon counting capabilities of each of these so-called microcells into a proportional light sensor. The discharge of a single microcell is relatively well understood and electronic models exist to simulate this process. In this paper we introduce an extended model that is able to simulate the simultaneous discharge of multiple cells. This model is used to predict the SiPM signal in response to fast light pulses as a function of the number of fired cells, taking into account the influence of the input impedance of the SiPM preamplifier. The model predicts that the electronic signal is not proportional to the number of fired cells if the preamplifier input impedance is not zero. This effect becomes more important for SiPMs with lower parasitic capacitance (which otherwise is a favorable property). The model is validated by comparing its predictions to experimental data obtained with two different SiPMs (Hamamatsu S10362-11-25u and Hamamatsu S10362-33-25c) illuminated with ps laser pulses. The experimental results are in good agreement with the model predictions.

  11. Characterization of the Hamamatsu R11265-103-M64 multi-anode photomultiplier tube for the LHCb RICH Upgrade

    CERN Document Server

    Matteuzzi, C; Carniti, P; Cassina, L; Giachero, A; Gotti, C; Khanji, B; Maino, M; Pessina, G

    2014-01-01

    The Hamamatsu R11265-103-M64 MaPMT is the baseline photon sensor to be used for the LHCb RICH Upgrade detector. This choice has been supported by a large number of tests of this device. This note summarizes the measurements performed by the INFN Milano Bicocca group to characterize the photon detector. A description is provided of the unpublished outcomes and particularly of the more recent developments about the aging of the R11265-103-M64 MaPMT and the test of a whole photon detector RICH Elementary Cell.

  12. HgCdTe APD-based linear-mode photon counting components and ladar receivers

    Science.gov (United States)

    Jack, Michael; Wehner, Justin; Edwards, John; Chapman, George; Hall, Donald N. B.; Jacobson, Shane M.

    2011-05-01

    Linear mode photon counting (LMPC) provides significant advantages in comparison with Geiger Mode (GM) Photon Counting including absence of after-pulsing, nanosecond pulse to pulse temporal resolution and robust operation in the present of high density obscurants or variable reflectivity objects. For this reason Raytheon has developed and previously reported on unique linear mode photon counting components and modules based on combining advanced APDs and advanced high gain circuits. By using HgCdTe APDs we enable Poisson number preserving photon counting. A metric of photon counting technology is dark count rate and detection probability. In this paper we report on a performance breakthrough resulting from improvement in design, process and readout operation enabling >10x reduction in dark counts rate to ~10,000 cps and >104x reduction in surface dark current enabling long 10 ms integration times. Our analysis of key dark current contributors suggest that substantial further reduction in DCR to ~ 1/sec or less can be achieved by optimizing wavelength, operating voltage and temperature.

  13. Hamamatsu C11204-01 calibration, test and design of a dedicated LabVIEW interface

    International Nuclear Information System (INIS)

    Nocerino, E.; Barbato, F.C.T.; De Asmundis, R.

    2017-01-01

    In the last 50 years solid state devices have been widely used as radiation detectors (photons, betas, fast electrons and heavy ions) thanks to the advantages they offer with respect to photomultiplier tubes technology. However, despite their benefits (low power consumption, small size, low costs), semiconductors are very sensitive to temperature variations. This means that for those experiments using solid state detectors without any thermal control, the correct operation of the detectors is affected by the environmental condition. To solve this problem Hamamatsu Photonics realized the C11204-01 device: a special voltage supply module for silicon photomultipliers which compensates the overvoltage at different temperatures. In the following work we present the results of the calibration of this device and a test we performed on a silicon photomultiplier, by means of a LabVIEW"T"M interface designed ad hoc for this purpose.

  14. Characterization of the Hamamatsu R11265-103-M64 multi-anode photomultiplier tube

    International Nuclear Information System (INIS)

    Cadamuro, L; Calvi, M; Cassina, L; Giachero, A; Gotti, C; Khanji, B; Maino, M; Matteuzzi, C; Pessina, G

    2014-01-01

    The aim of this paper is to fully characterize the new multi-anode photomultiplier tube R11265-103-M64, produced by Hamamatsu. Its high effective active area (77%), its pixel size, the low dark signal rate and the capability to detect single photon signals make this tube suitable for an application in high energy physics, such as for RICH detectors. Four tubes and two different bias voltage dividers have been tested. The results of a standard characterization of the gain and the anode uniformity, the dark signal rate, the cross-talk and the device behaviour as a function of temperature have been studied. The behaviour of the tube is studied in a longitudinal magnetic field up to 100 Gauss. Shields made of a high permeability material are also investigated. The deterioration of the device performance due to long time operation at intense light exposure is studied. A quantitative analysis of the variation of the gain and the dark signals rate due to the aging is described

  15. Studies on an automated gain stabilisation for the new APD read-out of the crystal barrel calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Pauli, Peter [HISKP Bonn (Germany); Collaboration: CBELSA/TAPS-Collaboration

    2016-07-01

    For the investigation of the nucleon spectrum it is not enough to measure only cross sections because of the large overlap of resonances. To disentangle these resonances, a partial wave analysis is needed. To find unambiguous solutions it is necessary to measure (double) polarisation observables. The CBELSA/TAPS experiment is an important tool to measure these observables in meson photoproduction off nucleons. To achieve a high efficiency in purely neutral reactions it is important to implement the main calorimeter into the first level trigger. To do so it is necessary to replace the current PIN photo diodes with new avalanche photo diodes (APDs). The new read-out is able to provide a timing signal that is fast enough to use it as a trigger while it does not impair the energy resolution of the calorimeter compared to the previous system. A drawback of APDs is their temperature dependency. To provide a stable gain throughout varying running conditions it is vital to monitor the temperature change and correct it if necessary. The poster shows an approach to ensure temperature stability where the temperature is monitored via a temperature sensitive NTC thermistor and the gain is adjusted via changes of the high voltage supply of the APDs. This method proved successful while it is easy to implement in all 1320 CsI(Tl) crystals of the calorimeter.

  16. APD Response Time Measurements for Future TOF-E Systems

    Science.gov (United States)

    Starkey, M. J.; Ogasawara, K.; Dayeh, M. A.; Desai, M. I.

    2017-12-01

    In space physics, the ability to detect ions is crucial to understanding plasma distributions in the solar wind. This usually typically requires the determination of the particle's mass, charge, and total energy. Current ion detection schemes are implemented in three sequential parts; an electrostatic analyzer for energy per charge (E/Q) measurements, a time-of-flight (TOF) for mass per charge (M/Q) measurements, and a solid-state detector (SSD) for total energy (E) measurements. Recent work has suggested the use of avalanche photodiode detectors (APD) for a simultaneous TOF and total energy (TOF-E) measurement system, which would replace traditional SSDs, simplify design, and reduce costs. Although TOF based ion spectrometry typically requires timing resolution of systems.

  17. Modeling of a sensitive time-of-flight flash LiDAR system

    Science.gov (United States)

    Fathipour, V.; Wheaton, S.; Johnson, W. E.; Mohseni, H.

    2016-09-01

    used for monitoring and profiling structures, range, velocity, vibration, and air turbulence. Remote sensing in the IR region has several advantages over the visible region, including higher transmitter energy while maintaining eye-safety requirements. Electron-injection detectors are a new class of detectors with high internal avalanche-free amplification together with an excess-noise-factor of unity. They have a cutoff wavelength of 1700 nm. Furthermore, they have an extremely low jitter. The detector operates in linear-mode and requires only bias voltage of a few volts. This together with the feedback stabilized gain mechanism, makes formation of large-format high pixel density electron-injection FPAs less challenging compared to other detector technologies such as avalanche photodetectors. These characteristics make electron-injection detectors an ideal choice for flash LiDAR application with mm scale resolution at longer ranges. Based on our experimentally measured device characteristics, a detailed theoretical LiDAR model was developed. In this model we compare the performance of the electron-injection detector with commercially available linear-mode InGaAs APD from (Hamamatsu G8931-20) as well as a p-i-n diode (Hamamatsu 11193 p-i-n). Flash LiDAR images obtained by our model, show the electron-injection detector array (of 100 x 100 element) achieves better resolution with higher signal-to-noise compared with both the InGaAs APD and the p-i-n array (of 100 x 100 element).

  18. Digital electronics for 256 anode Hamamatsu H9500 PSPMT arrays in full-volume Compton imagers

    International Nuclear Information System (INIS)

    Harris, J T; Grudberg, P M; Warburton, W K

    2014-01-01

    Ziock et al.'s [1] recent Monte Carlo study of a proposed ''full-volume'' Compton Imaging Camera concluded that simultaneously locating a Compton scatter event's multiple interaction points within a single large scintillator crystal might be possible at 1 mm spatial resolution using a coded aperture mask sandwiched between two light guides and coupled to a position sensitive photomultiplier (PSPMT) to record the output light pattern. The method promises high efficiency at a relatively low cost. They are currently developing a lower resolution prototype using a large cubic scintillator (25.4 cm/side) whose masked face will be tiled with 25 Hamamatsu H9500 PSPMTs (6,400 outputs). XIA has contracted to develop and produce the readout electronics, which present several significant design challenges, including capturing all 6,400 anode outputs individually, with single photon sensitivity, in a compact format that will fit behind the tiled PSPMTs. 10,000 event/sec operation is desired, as is a cost of less than about $50/channel. In our approach, each PSPMT front end integrates the 256 anode signals and 8-1 multiplexes them to 32 differential outputs that are digitized in a PXI card using 4 octal 50 MHz ADCs. The multiplexers run at 8 MHz, sampling each anode at 1 MHz, which becomes the image frame rate. The ADC signals are demultiplexed and digitally filtered to extract the number of photons in each pixel in the full 2-D image. The design has been completed and built and is undergoing evaluation tests at the single PSPMT level

  19. Imaging performance of LabPET APD-based digital PET scanners for pre-clinical research

    International Nuclear Information System (INIS)

    Bergeron, Mélanie; Cadorette, Jules; Beaudoin, Jean-François; Lecomte, Roger; Tétrault, Marc-André; Leroux, Jean-Daniel; Fontaine, Réjean

    2014-01-01

    The LabPET is an avalanche photodiode (APD) based digital PET scanner with quasi-individual detector read-out and highly parallel electronic architecture for high-performance in vivo molecular imaging of small animals. The scanner is based on LYSO and LGSO scintillation crystals (2×2×12/14 mm 3 ), assembled side-by-side in phoswich pairs read out by an APD. High spatial resolution is achieved through the individual and independent read-out of an individual APD detector for recording impinging annihilation photons. The LabPET exists in three versions, LabPET4 (3.75 cm axial length), LabPET8 (7.5 cm axial length) and LabPET12 (11.4 cm axial length). This paper focuses on the systematic characterization of the three LabPET versions using two different energy window settings to implement a high-efficiency mode (250–650 keV) and a high-resolution mode (350–650 keV) in the most suitable operating conditions. Prior to measurements, a global timing alignment of the scanners and optimization of the APD operating bias have been carried out. Characteristics such as spatial resolution, absolute sensitivity, count rate performance and image quality have been thoroughly investigated following the NEMA NU 4-2008 protocol. Phantom and small animal images were acquired to assess the scanners' suitability for the most demanding imaging tasks in preclinical biomedical research. The three systems achieve the same radial FBP spatial resolution at 5 mm from the field-of-view center: 1.65/3.40 mm (FWHM/FWTM) for an energy threshold of 250 keV and 1.51/2.97 mm for an energy threshold of 350 keV. The absolute sensitivity for an energy window of 250–650 keV is 1.4%/2.6%/4.3% for LabPET4/8/12, respectively. The best count rate performance peaking at 362 kcps is achieved by the LabPET12 with an energy window of 250–650 keV and a mouse phantom (2.5 cm diameter) at an activity of 2.4 MBq ml −1 . With the same phantom, the scatter fraction for all scanners is about

  20. Long-term operation of a multi-channel cosmic muon system based on scintillation counters with MRS APD light readout

    CERN Document Server

    Akindinov, A.; Grigoriev, E.; Grishuk, Yu.; Kuleshov, S.; Mal'kevich, D.; Martemiyanov, A.; Nedosekin, A.; Ryabinin, M.; Voloshin, K.

    2009-01-01

    A Cosmic Ray Test Facility (CRTF) is the first large-scale implementation of a scintillation triggering system based on a new scintillation technique known as START. In START, the scintillation light is collected and transported by WLS optical fibers, while light detection is performed by pairs of avalanche photodiodes with the Metal-Resistor-Semiconductor structure operated in the Geiger mode (MRS APD). START delivers 100% efficiency of cosmic muon detection, while its intrinsic noise level is less than 10^{-2} Hz. CRTF, consisting of 160 START channels, has been continuously operated by the ALICE TOF collaboration for more than 25 000 hours, and has demonstrated a high level of stability. Fewer than 10% of MRS APDs had to be replaced during this period.

  1. The roles played by the Canadian General Electric Company's Atomic Power Department in Canada's nuclear power program: work, organization and success in APD, 1955-1995

    International Nuclear Information System (INIS)

    Cantello, G.W.

    2003-01-01

    This thesis explores the roles played by the Canadian General Electric Company's Atomic Power Department (APD) in Canada's distinctive nuclear power program. From the establishment of APD in 1955 until the completion of the KANUPP project in Pakistan in 1972, the company's strategy encompassed the design, manufacture, and commissioning of entire nuclear power projects in Canada and abroad. APD then developed a specialized role in the design and supply of complete nuclear fuel handling systems, nuclear fuel bundles, and service work, that sustained a thriving workplace. Five key factors are identified as the reasons behind the long and successful history of the department: (1) Strong, capable and efficient management from the start, (2) Flexible organizational structure, (3) Extremely competent design group, (4) Excellent manufacturing, test, commissioning and service capabilities, (5) Correctly identifying, at the right time, the best fields in which to specialize. (author)

  2. Systematic study of new types of Hamamatsu MPPCs read out with the NINO ASIC

    CERN Document Server

    Doroud, K; Williams, M C S; Yamamoto, K; Zichichi, A; Zuyeuski, R

    2014-01-01

    Over the last decade there have been commercial TOF-PET scanners constructed using Photo-Multiplier Tubes (PMT) that have achieved View the MathML source~500ps FWHM Coincidence Time Resolution (CTR). A new device known as the Silicon PhotoMultiplier (SiPM) has the potential to overcome some of the limitations of the PMT. Therefore implementing a SiPM based TOF-PET scanner is of high interest. Recently Philips has introduced a TOF-PET scanner that uses digital Silicon PhotoMultipliers (d-SiPMs) which has a CTR of 350 ps. Here we will report on the timing performance of two Hamamatsu 3×3 mm2 analogue-SiPMs read out with the NINO ASIC: this is an ultra-fast amplifier/discriminator with a differential architecture. The differential architecture is very important since the single-ended readout uses the ground as the signal return; as the ground is also the reference level for the discriminators, the result is high crosstalk and degraded time resolution. However differential readout allows the scaling up from a si...

  3. Characterization of new hexagonal large area Geiger Avalanche Photodiodes

    International Nuclear Information System (INIS)

    Boccone, V.; Aguilar, J.A.; Della Volpe, D.; Christov, A.; Montaruli, T.; Rameez, M.; Basili, A.

    2013-06-01

    Photomultipliers (PMTs) are the standard detector for construction of the current generation of imaging Atmospheric Cherenkov Telescopes (IACTs). Despite impressive improvements in QE and reliability in the last years, these devices suffer from the limitation of being unable to operate in the partially illuminated sky (during full or partial moon periods) as the excess light leads to a significant increase in the rate of ageing of the devices themselves and consequently limit the life of the camera. A viable alternative is the large area Geiger-mode avalanche photodiodes (G-APDs also known as Silicon Photomultipliers or SiPMs) that are commercially available from different producers in various types and dimensions. The sufficiency of the maturity of this technology for application to Cherenkov Astronomy has already been demonstrated by the FACT telescope. One of the camera designs under study for the 4 m Davies Cotton Telescope foresees the utilization of a large area G-APDs coupled to non imaging light concentrators. In collaboration with Hamamatsu and deriving from their current technology, we have designed a new hexagonal shaped large area G-APD HEX S12516 which when coupled to a Winston cone of 24 degrees cutting angle allows for a pixel angular resolution of 0.25 degrees for a f/D 1.4 telescope with a diameter of 4 m. The device, available in 2 different cell size configurations (50 μm and 100 μm), is divided into 4 different channels powered in common cathode mode. A temperature sensor was included for a better temperature evaluation in the characterization phase. The first 3 prototypes were fully characterized and the results are compared to the larger area devices commercially available such as the S10985-050C (2x2 array of 3x3 mm 2 G-APDs). The photo-detection efficiency is measured applying the Poisson statistics method using pulsed LED at 7 different wavelengths from 355 to 670 nm and for different bias over-voltages (V ov ). Optical crosstalk and

  4. Radiological manifestations of biphosphonate treatment with APD in a child suffering from osteogenesis imperfecta

    Energy Technology Data Exchange (ETDEWEB)

    Devogelaer, J.P.; Deuxchaisnes, C.N. de; Malghem, J.; Maldague, B.

    1987-07-01

    A 12-year-old female suffering fromosteogenesis imperfecta (OI) was treated with 3-amino-1-hydroxypropylidene-1,1-bisphosphonate (APD) orally, 250 mg daily, for periods of 2 months, alternating with periods of 2 months of abstinence. Total duration of therapy was 1 year. Radiological and clinical improvement was striking. Furthermore, X-rays of the bones showed large, parallel radio-opaque striae, corresponding exactly to the periods of therapy. These were present in all metaphyses.

  5. A prospective, randomized multicenter study comparing APD and CAPD treatment

    DEFF Research Database (Denmark)

    Bro, S; Bjorner, J B; Tofte-Jensen, P

    2000-01-01

    , dialysis-related complications, dialysis-related expenses. RESULTS: The quality-of-life studies showed that significantly more time for work, family, and social activities was available to patients on APD compared to those on CAPD (p ...) treatment with respect to quality of life and clinical outcomes in relation to therapy costs. DESIGN: A prospective, randomized multicenter study. SETTING: Three Danish CAPD units. PATIENTS: Thirty-four adequately dialyzed patients with high or high-average peritoneal transport characteristics were included...... were assessed at baseline and after 6 months by the self-administered short-form SF-36 generic health survey questionnaire supplemented with disease- and treatment-specific questions. Therapy costs were compared by evaluating dialysis-related expenses. MAIN OUTCOME MEASURES: Quality-of-life parameters...

  6. Using Deep Learning for Gamma Ray Source Detection at the First G-APD Cherenkov Telescope (FACT)

    Science.gov (United States)

    Bieker, Jacob

    2018-06-01

    Finding gamma-ray sources is of paramount importance for Imaging Air Cherenkov Telescopes (IACT). This study looks at using deep neural networks on data from the First G-APD Cherenkov Telescope (FACT) as a proof-of-concept of finding gamma-ray sources with deep learning for the upcoming Cherenkov Telescope Array (CTA). In this study, FACT’s individual photon level observation data from the last 5 years was used with convolutional neural networks to determine if one or more sources were present. The neural networks used various architectures to determine which architectures were most successful in finding sources. Neural networks offer a promising method for finding faint and extended gamma-ray sources for IACTs. With further improvement and modifications, they offer a compelling method for source detection for the next generation of IACTs.

  7. Radiation damage of pixelated photon detector by neutron irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Isamu [KEK, 1-1 Oho Tsukuba 305-0801 (Japan)], E-mail: isamu.nakamura@kek.jp

    2009-10-21

    Radiation Damage of Pixelated Photon Detector by neutron irradiation is reported. MPPC, one of PPD or Geiger-mode APD, developed by Hamamatsu Photonics, is planned to be used in many high energy physics experiments. In such experiments radiation damage is a serious issue. A series of neutron irradiation tests is performed at the Reactor YAYOI of the University of Tokyo. MPPCs were irradiated at the reactor up to 10{sup 12}neutron/cm{sup 2}. In this paper, the effect of neutron irradiation on the basic characteristics of PPD including gain, noise rate, photon detection efficiency is presented.

  8. Radiological manifestations of biphosphonate treatment with APD in a child suffering from osteogenesis imperfecta

    International Nuclear Information System (INIS)

    Devogelaer, J.P.; Deuxchaisnes, C.N. de; Malghem, J.; Maldague, B.

    1987-01-01

    A 12-year-old female suffering fromosteogenesis imperfecta (OI) was treated with 3-amino-1-hydroxypropylidene-1,1-bisphosphonate (APD) orally, 250 mg daily, for periods of 2 months, alternating with periods of 2 months of abstinence. Total duration of therapy was 1 year. Radiological and clinical improvement was striking. Furthermore, X-rays of the bones showed large, parallel radio-opaque striae, corresponding exactly to the periods of therapy. These were present in all metaphyses. (orig.)

  9. APD detectors for biological fluorescence spectroscopy

    International Nuclear Information System (INIS)

    Mazeres, S.; Borrel, V.; Magenc, C.; Courrech, J.L.; Bazer-Bachi, R.

    2006-01-01

    Fluorescence spectroscopy is a very convenient and widely used method for studying the molecular background of biological processes [L. Salome, J.L. Cazeil, A. Lopez, J.F. Tocanne, Eur. Biophys. J. 27 (1998) 391-402]. Chromophores are included in the structure under study and a flash of laser light induces fluorescence (Fluorescence Recovery After Photo-bleaching), the decay of which yields information on the polarity, the speed of rotation, and the speed of diffusion as well as on the temporal and spatial evolution of interactions between molecular species. The method can even be used to study living cells [J.F. Tocanne, L. Cezanne, A. Lopez, Prog. Lipid Res. 33 (1994) 203-237, L. Cezanne, A. Lopez, F. Loste, G. Parnaud, O. Saurel, P. Demange, J.F. Tocanne, Biochemistry 38 (1999) 2779-2786]. This is classically performed with a PM-based system. For biological reasons a decrease of the excitation of the cells is highly desirable. Because the fluorescence response then becomes fainter a significant improvement in detector capability would be welcome. We present here results obtained with an Avalanche Photo Diode (APD)-based system. The small sensitive area of detection allows a very significant improvement in signal/noise ratio, improvement in gain, and the opening-up of a new parameter space. With these new detectors we can begin the study of information transmission between cells through morphine receptors. This work involves both electronics engineers and biophysicists, so results and techniques in both fields will be presented here

  10. The Magnetar Model of the Superluminous Supernova GAIA16apd and the Explosion Jet Feedback Mechanism

    International Nuclear Information System (INIS)

    Soker, Noam

    2017-01-01

    Under the assumption that jets explode core collapse supernovae (CCSNe) in a negative jet feedback mechanism (JFM), this paper shows that rapidly rotating neutron stars are likely to be formed when the explosion is very energetic. Under the assumption that an accretion disk or an accretion belt around the just-formed neutron star launch jets and that the accreted gas spins-up the just-formed neutron star, I derive a crude relation between the energy that is stored in the spinning neutron star and the explosion energy. This relation is ( E _N_S_-_s_p_i_n/ E _e_x_p) ≈ E _e_x_p/10"5"2 erg; It shows that within the frame of the JFM explosion model of CCSNe, spinning neutron stars, such as magnetars, might have significant energy in super-energetic explosions. The existence of magnetars, if confirmed, such as in the recent super-energetic supernova GAIA16apd, further supports the call for a paradigm shift from neutrino-driven to jet-driven CCSN mechanisms.

  11. Four channel Cosmic Ray detector based on polymaq

    Science.gov (United States)

    Herrera-Guzman, K. N.; Gutierrez-Sanchez, R. A.; Felix, J.

    2017-01-01

    The Cherenkov radiation has been widely studied in transparent materials, and applied to detect and identify elementary particles. But it has not been widely studied in opaque materials. A four channels radiation detector has been designed, built, characterized, and operated; based on four polymaq (UHMW-PE) bars of 2.54 cm X 5.08 cm X 25.4 cm, which is an opaque material to visible radiation to the human eye. Silicon photo detectors, Hamamatsu, avalanche type (APD) are used to detect the radiation produced by the passage of particles in the detector blocks. The design, construction, characterization, operation, and preliminary results of this cosmic ray detector details are presented.

  12. AX-PET: A novel PET concept with G-APD readout

    CERN Document Server

    Heller, M; Casella, C; Chesi, E; De Leo, R; Dissertori, G; Fanti, V; Gillam, J E; Joram, C; Lustermann, W; Nappi, E; Oliver, J F; Pauss, F; Rafecas, M; Rudge, A; Ruotsalainen, U; Schinzel, D; Schneider, T; Seguinot, J; Solevi, P; Stapnes, S; Tuna, U; Weilhammer, P

    2012-01-01

    The AX-PET collaboration has developed a novel concept for high resolution PET imaging to overcome some of the performance limitations of classical PET cameras, in particular the compromise between spatial resolution and sensitivity introduced by the parallax error. The detector consists of an arrangement of long LYSO scintillating crystals axially oriented around the field of view together with arrays of wave length shifter strips orthogonal to the crystals. This matrix allows a precise 3D measurement of the photon interaction point. This is valid both for photoelectric absorption at 511 key and for Compton scattering down to deposited energies of about 100 keV. Crystals and WLS strips are individually read out using Geiger-mode Avalanche Photo Diodes (G-APDs). The sensitivity of such a detector can be adjusted by changing the number of layers and the resolution is defined by the crystal and strip dimensions. Two AX-PET modules were built and fully characterized in dedicated test set-ups at CERN, with point-...

  13. Pixel readout ASIC for an APD based 2D X-ray hybrid pixel detector with sub-nanosecond resolution

    Energy Technology Data Exchange (ETDEWEB)

    Thil, Ch., E-mail: christophe.thil@ziti.uni-heidelberg.d [Heidelberg University, Institute of Computer Engineering, B6, 26, 68161 Mannheim (Germany); Baron, A.Q.R. [RIKEN SPring-8 Center, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5148 (Japan); Fajardo, P. [ESRF, Polygone Scientifique Louis Neel, 6, rue Jules Horowitz, 38000 Grenoble (France); Fischer, P. [Heidelberg University, Institute of Computer Engineering, B6, 26, 68161 Mannheim (Germany); Graafsma, H. [DESY, Notkestrasse 85, 22607 Hamburg (Germany); Rueffer, R. [ESRF, Polygone Scientifique Louis Neel, 6, rue Jules Horowitz, 38000 Grenoble (France)

    2011-02-01

    The fast response and the short recovery time of avalanche photodiodes (APDs) in linear mode make those devices ideal for direct X-ray detection in applications requiring high time resolution or counting rate. In order to provide position sensitivity, the XNAP project aims at creating a hybrid pixel detector with nanosecond time resolution based on a monolithic APD sensor array with 32 x32 pixels covering about 1 cm{sup 2} active area. The readout is implemented in a pixelated front-end ASIC suited for the readout of such arrays, matched to pixels of 280{mu}mx280{mu}m size. Every single channel features a fast transimpedance amplifier, a discriminator with locally adjustable threshold and two counters with high dynamic range and counting speed able to accumulate X-ray hits with no readout dead time. Additionally, the detector can be operated in list mode by time-stamping every single event with sub-nanosecond resolution. In a first phase of the project, a 4x4 pixel test module is built to validate the conceptual design of the detector. The XNAP project is briefly presented and the performance of the readout ASIC is discussed.

  14. Pixel readout ASIC for an APD based 2D X-ray hybrid pixel detector with sub-nanosecond resolution

    International Nuclear Information System (INIS)

    Thil, Ch.; Baron, A.Q.R.; Fajardo, P.; Fischer, P.; Graafsma, H.; Rueffer, R.

    2011-01-01

    The fast response and the short recovery time of avalanche photodiodes (APDs) in linear mode make those devices ideal for direct X-ray detection in applications requiring high time resolution or counting rate. In order to provide position sensitivity, the XNAP project aims at creating a hybrid pixel detector with nanosecond time resolution based on a monolithic APD sensor array with 32 x32 pixels covering about 1 cm 2 active area. The readout is implemented in a pixelated front-end ASIC suited for the readout of such arrays, matched to pixels of 280μmx280μm size. Every single channel features a fast transimpedance amplifier, a discriminator with locally adjustable threshold and two counters with high dynamic range and counting speed able to accumulate X-ray hits with no readout dead time. Additionally, the detector can be operated in list mode by time-stamping every single event with sub-nanosecond resolution. In a first phase of the project, a 4x4 pixel test module is built to validate the conceptual design of the detector. The XNAP project is briefly presented and the performance of the readout ASIC is discussed.

  15. Time resolution of Burle 85001 micro-channel plate photo-multipliers in comparison with Hamamatsu R2083

    Energy Technology Data Exchange (ETDEWEB)

    V. Baturin; V. Burkert; W. Kim; S. Majewsky; D. Nekrasov; K. Park; V. Popov; E. S. Smith; D. Son; S. S. Stepanyan; C. Zorn

    2005-06-01

    The CLAS detector will require improvements in its particle identification system to take advantage of the higher energies provided by the Jefferson Laboratory accelerator upgrade to 12 GeV. To this end, we have studied the timing characteristics of the micro-channel plate photo-multiplier 85001 from Burle, which can be operated in a high magnetic field environment. For reference and comparison, measurements were also made using the standard PMT R2083 from Hamamatsu using two timing methods. The cosmic ray method, which utilizes three identical scintillating counters 2cm x 3cm x 50cm with PMs at the ends, yields 59.1(0.7)ps. The location method of particles from radiative source with known coordinates has been used to compare timing resolutions of R2083 and Burle-85001. This ''coordinate method'' requires only one counter instrumented with two PMs and it yields 59.5(0.7)ps. For the micro-channel plate photomultiplier from Burle with an external amplification of 10 to the signals, the co ordinate method yields 130(4)ps. This method also makes it possible to estimate the number of primary photo-electrons.

  16. Design and implementation of Gm-APD array readout integrated circuit for infrared 3D imaging

    Science.gov (United States)

    Zheng, Li-xia; Yang, Jun-hao; Liu, Zhao; Dong, Huai-peng; Wu, Jin; Sun, Wei-feng

    2013-09-01

    A single-photon detecting array of readout integrated circuit (ROIC) capable of infrared 3D imaging by photon detection and time-of-flight measurement is presented in this paper. The InGaAs avalanche photon diodes (APD) dynamic biased under Geiger operation mode by gate controlled active quenching circuit (AQC) are used here. The time-of-flight is accurately measured by a high accurate time-to-digital converter (TDC) integrated in the ROIC. For 3D imaging, frame rate controlling technique is utilized to the pixel's detection, so that the APD related to each pixel should be controlled by individual AQC to sense and quench the avalanche current, providing a digital CMOS-compatible voltage pulse. After each first sense, the detector is reset to wait for next frame operation. We employ counters of a two-segmental coarse-fine architecture, where the coarse conversion is achieved by a 10-bit pseudo-random linear feedback shift register (LFSR) in each pixel and a 3-bit fine conversion is realized by a ring delay line shared by all pixels. The reference clock driving the LFSR counter can be generated within the ring delay line Oscillator or provided by an external clock source. The circuit is designed and implemented by CSMC 0.5μm standard CMOS technology and the total chip area is around 2mm×2mm for 8×8 format ROIC with 150μm pixel pitch. The simulation results indicate that the relative time resolution of the proposed ROIC can achieve less than 1ns, and the preliminary test results show that the circuit function is correct.

  17. Performances of a HGCDTE APD based direct detection lidar at 2 μm. Application to dial measurements

    Science.gov (United States)

    Gibert, Fabien; Dumas, Arnaud; Rothman, Johan; Edouart, Dimitri; Cénac, Claire; Pellegrino, Jessica

    2018-04-01

    A lidar receiver with a direct detection chain adapted to a HgCdTe APD based detector with electric cooling is associated to a 2.05 μm Ho :YLF pulsed dual wavelength single mode transmitter to provide the first atmospheric lidar measurements using this technology. Experiments confirm the outstanding sensitivity of the detector and hightligth its huge potential for DIAL measurements of trace gas (CO2 and H2O) in this spectral domain. Performances of coherent vs direct detection at 2.05 μm is assessed.

  18. Performances of a HGCDTE APD based direct detection lidar at 2 μm. Application to dial measurements

    Directory of Open Access Journals (Sweden)

    Gibert Fabien

    2018-01-01

    Full Text Available A lidar receiver with a direct detection chain adapted to a HgCdTe APD based detector with electric cooling is associated to a 2.05 μm Ho :YLF pulsed dual wavelength single mode transmitter to provide the first atmospheric lidar measurements using this technology. Experiments confirm the outstanding sensitivity of the detector and hightligth its huge potential for DIAL measurements of trace gas (CO2 and H2O in this spectral domain. Performances of coherent vs direct detection at 2.05 μm is assessed.

  19. An Ultraviolet Excess in the Superluminous Supernova Gaia16apd Reveals a Powerful Central Engine

    Energy Technology Data Exchange (ETDEWEB)

    Nicholl, M.; Berger, E.; Blanchard, P. K.; Milisavljevic, D.; Challis, P. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, Massachusetts 02138 (United States); Margutti, R. [Center for Interdisciplinary Exploration and Research in Astrophysics (CIERA) and Department of Physics and Astronomy, Northwestern University, Evanston, IL 60208 (United States); Metzger, B. D. [Columbia Astrophysics Laboratory, Columbia University, New York, NY 10027 (United States); Chornock, R., E-mail: matt.nicholl@cfa.harvard.edu [Astrophysical Institute, Department of Physics and Astronomy, 251B Clippinger Lab, Ohio University, Athens, OH 45701 (United States)

    2017-01-20

    Since the discovery of superluminous supernovae (SLSNe) in the last decade, it has been known that these events exhibit bluer spectral energy distributions than other supernova subtypes, with significant output in the ultraviolet. However, the event Gaia16apd seems to outshine even the other SLSNe at rest-frame wavelengths below ∼3000 Å. Yan et al. have recently presented HST UV spectra and attributed the UV flux to low iron-group abundance in the outer ejecta, and hence reduced line blanketing. Here, we present UV and optical light curves over a longer baseline in time, revealing a rapid decline at UV wavelengths despite a typical optical evolution. Combining the published UV spectra with our own optical data, we demonstrate that Gaia16apd has a much hotter continuum than virtually any SLSN at maximum light, but it cools rapidly thereafter and is indistinguishable from the others by ∼10–15 days after peak. Comparing the equivalent widths of UV absorption lines with those of other events, we show that the excess UV continuum is a result of a more powerful central power source, rather than a lack of UV absorption relative to other SLSNe or an additional component from interaction with the surrounding medium. These findings strongly support the central-engine hypothesis for hydrogen-poor SLSNe. An explosion ejecting M {sub ej} = 4.8(0.2/ κ ) M {sub ⊙}, where κ is the opacity in cm{sup 2} g{sup −1}, and forming a magnetar with spin period P = 2 ms, and B = 2 × 10{sup 14} G (lower than other SLSNe with comparable rise times) can consistently explain the light curve evolution and high temperature at peak. The host metallicity, Z = 0.18 Z {sub ⊙}, is comparable to other SLSNe.

  20. Poster - 01: LabPET II Pixelated APD-Based PET Scanner for High-Resolution Preclinical Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lecomte, Roger; Arpin, Louis; Beaudoin, Jean-François; Bergeron, Mélanie; Bouchard, Jonathan; Bouziri, Haithem; Cadorette, Jules; Gaudin, Émilie; Jürgensen, Nadia; Koua, Konin Calliste; Trépanier, Pierre-Yves Lauzier; Leroux, Jean-Daniel; Loignon-Houle, Francis; Njejimana, Larissa; Paillé, Maxime; Paulin, Caroline; Pepin, Catherine; Pratte, Jean-François; Samson, Arnaud; Thibaudeau, Christian [Université de Sherbrooke, Université de Sherbrooke, CIMS/CRCHUS, Université de Sherbrooke, Université de Sherbrooke, Université de Sherbrooke, CIMS/CRCHUS, Université de Sherbrooke, Université de Sherbrooke, 3IT, Université de Sherbrooke, Novalgo Inc., Université de Sherbrooke, Université de Sherbrooke, CIMS/CRCHUS, 3IT, Université de Sherbrooke, Université de Sherbrooke, Université de Sherbrooke, Université de Sherbrooke, 3IT, Université de Sherbrooke (Canada); and others

    2016-08-15

    Purpose: LabPET II is a new generation APD-based PET scanner designed to achieve sub-mm spatial resolution using truly pixelated detectors and highly integrated parallel front-end processing electronics. Methods: The basic element uses a 4×8 array of 1.12×1.12 mm{sup 2} Lu{sub 1.9}Y{sub 0.1}SiO{sub 5}:Ce (LYSO) scintillator pixels with one-to-one coupling to a 4×8 pixelated monolithic APD array mounted on a ceramic carrier. Four detector arrays are mounted on a daughter board carrying two flip-chip, 64-channel, mixed-signal, application-specific integrated circuits (ASIC) on the backside interfacing to two detector arrays each. Fully parallel signal processing was implemented in silico by encoding time and energy information using a dual-threshold Time-over-Threshold (ToT) scheme. The self-contained 128-channel detector module was designed as a generic component for ultra-high resolution PET imaging of small to medium-size animals. Results: Energy and timing performance were optimized by carefully setting ToT thresholds to minimize the noise/slope ratio. ToT spectra clearly show resolved 511 keV photopeak and Compton edge with ToT resolution well below 10%. After correction for nonlinear ToT response, energy resolution is typically 24±2% FWHM. Coincidence time resolution between opposing 128-channel modules is below 4 ns FWHM. Initial imaging results demonstrate that 0.8 mm hot spots of a Derenzo phantom can be resolved. Conclusion: A new generation PET scanner featuring truly pixelated detectors was developed and shown to achieve a spatial resolution approaching the physical limit of PET. Future plans are to integrate a small-bore dedicated mouse version of the scanner within a PET/CT platform.

  1. Performances of a HGCDTE APD Based Detector with Electric Cooling for 2-μm DIAL/IPDA Applications

    Directory of Open Access Journals (Sweden)

    Dumas A.

    2016-01-01

    Full Text Available In this work we report on design and testing of an HgCdTe Avalanche Photodiode (APD detector assembly for lidar applications in the Short Wavelength Infrared Region (SWIR : 1,5 - 2 μm. This detector consists in a set of diodes set in parallel -making a 200 μm large sensitive area- and connected to a custom high gain TransImpedance Amplifier (TIA. A commercial four stages Peltier cooler is used to reach an operating temperature of 185K. Crucial performances for lidar use are investigated : linearity, dynamic range, spatial homogeneity, noise and resistance to intense illumination.

  2. Development of a novel depth of interaction PET detector using highly multiplexed G-APD cross-strip encoding

    Energy Technology Data Exchange (ETDEWEB)

    Kolb, A., E-mail: armin.kolb@med.uni-tuebingen.de; Parl, C.; Liu, C. C.; Pichler, B. J. [Werner Siemens Imaging Center, Department of Preclinical Imaging and Radiopharmacy, Eberhard Karls University, 72076 Tübingen (Germany); Mantlik, F. [Werner Siemens Imaging Center, Department of Preclinical Imaging and Radiopharmacy, Eberhard Karls University, 72076 Tübingen, Germany and Department of Empirical Inference, Max Planck Institute for Intelligent Systems, 72076 Tübingen (Germany); Lorenz, E. [Max Planck Institute for Physics, Föhringer Ring 6, 80805 München (Germany); Renker, D. [Department of Physics, Technische Universität München, 85748 Garching (Germany)

    2014-08-15

    Purpose: The aim of this study was to develop a prototype PET detector module for a combined small animal positron emission tomography and magnetic resonance imaging (PET/MRI) system. The most important factor for small animal imaging applications is the detection sensitivity of the PET camera, which can be optimized by utilizing longer scintillation crystals. At the same time, small animal PET systems must yield a high spatial resolution. The measured object is very close to the PET detector because the bore diameter of a high field animal MR scanner is limited. When used in combination with long scintillation crystals, these small-bore PET systems generate parallax errors that ultimately lead to a decreased spatial resolution. Thus, we developed a depth of interaction (DoI) encoding PET detector module that has a uniform spatial resolution across the whole field of view (FOV), high detection sensitivity, compactness, and insensitivity to magnetic fields. Methods: The approach was based on Geiger mode avalanche photodiode (G-APD) detectors with cross-strip encoding. The number of readout channels was reduced by a factor of 36 for the chosen block elements. Two 12 × 2 G-APD strip arrays (25μm cells) were placed perpendicular on each face of a 12 × 12 lutetium oxyorthosilicate crystal block with a crystal size of 1.55 × 1.55 × 20 mm. The strip arrays were multiplexed into two channels and used to calculate the x, y coordinates for each array and the deposited energy. The DoI was measured in step sizes of 1.8 mm by a collimated {sup 18}F source. The coincident resolved time (CRT) was analyzed at all DoI positions by acquiring the waveform for each event and applying a digital leading edge discriminator. Results: All 144 crystals were well resolved in the crystal flood map. The average full width half maximum (FWHM) energy resolution of the detector was 12.8% ± 1.5% with a FWHM CRT of 1.14 ± 0.02 ns. The average FWHM DoI resolution over 12 crystals was 2.90

  3. A positron emission tomograph based on LSO-APD modules with a sampling ADC read-out system for a students' advanced laboratory course

    International Nuclear Information System (INIS)

    Schneider, Florian R.; Mann, Alexander B.; Technische Univ. Muenchen, Klinikum rechts der Isar; Konorov, Igor; Paul, Stephan; Delso, Gaspar; Ziegler, Sibylle I.

    2012-01-01

    A one-day laboratory course on positron emission tomography (PET) for the education of physics students and PhD students in medical physics has been set up. In the course, the physical background and the principles of a PET scanner are introduced. Course attendees set the system in operation, calibrate it using a 22 Na point source and reconstruct different source geometries filled with 18 F. The PET scanner features an individual channel read-out of 96 lutetium oxyorthosilicate (LSO) scintillator crystals coupled to avalanche photodiodes (APD). The analog data of each APD are digitized by fast sampling analog to digital converters (SADC) and processed within field programmable gate arrays (FPGA) to extract amplitudes and time stamps. All SADCs are continuously sampling with a precise rate of 80 MHz, which is synchronous for the whole system. The data is transmitted via USB to a Linux PC, where further processing and the image reconstruction are performed. The course attendees get an insight into detector techniques, modern read-out electronics, data acquisition and PET image reconstruction. In addition, a short introduction to some common software applications used in particle and high energy physics is part of the course. (orig.)

  4. A positron emission tomograph based on LSO-APD modules with a sampling ADC read-out system for a students' advanced laboratory course

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, Florian R.; Mann, Alexander B. [Technische Univ. Muenchen, Garching (Germany). Physik-Department E18; Technische Univ. Muenchen, Klinikum rechts der Isar (Germany). Nuklearmedizinische Klinik und Poliklinik; Konorov, Igor; Paul, Stephan [Technische Univ. Muenchen, Garching (Germany). Physik-Department E18; Delso, Gaspar; Ziegler, Sibylle I. [Technische Univ. Muenchen, Klinikum rechts der Isar (Germany). Nuklearmedizinische Klinik und Poliklinik

    2012-07-01

    A one-day laboratory course on positron emission tomography (PET) for the education of physics students and PhD students in medical physics has been set up. In the course, the physical background and the principles of a PET scanner are introduced. Course attendees set the system in operation, calibrate it using a {sup 22}Na point source and reconstruct different source geometries filled with {sup 18}F. The PET scanner features an individual channel read-out of 96 lutetium oxyorthosilicate (LSO) scintillator crystals coupled to avalanche photodiodes (APD). The analog data of each APD are digitized by fast sampling analog to digital converters (SADC) and processed within field programmable gate arrays (FPGA) to extract amplitudes and time stamps. All SADCs are continuously sampling with a precise rate of 80 MHz, which is synchronous for the whole system. The data is transmitted via USB to a Linux PC, where further processing and the image reconstruction are performed. The course attendees get an insight into detector techniques, modern read-out electronics, data acquisition and PET image reconstruction. In addition, a short introduction to some common software applications used in particle and high energy physics is part of the course. (orig.)

  5. Systematic study of new types of Hamamatsu MPPCs read out with the NINO ASIC

    Energy Technology Data Exchange (ETDEWEB)

    Doroud, K. [Museo Storico della Fisica e Centro Studi e Ricerche E. Fermi, Roma (Italy); Rodriguez, A. [CERN, Geneva (Switzerland); ICSC World Laboratory, Geneva (Switzerland); Williams, M.C.S., E-mail: crispin.williams@cern.ch [CERN, Geneva (Switzerland); INFN and Dipartimento di Fisica e Astronomia, Università di Bologna (Italy); Yamamoto, K. [Solid State Division, Hamamatsu Photonics K.K., Hamamatsu (Japan); Zichichi, A. [Museo Storico della Fisica e Centro Studi e Ricerche E. Fermi, Roma (Italy); CERN, Geneva (Switzerland); INFN and Dipartimento di Fisica e Astronomia, Università di Bologna (Italy); Zuyeuski, R. [CERN, Geneva (Switzerland); ICSC World Laboratory, Geneva (Switzerland)

    2014-07-01

    Over the last decade there have been commercial TOF-PET scanners constructed using Photo-Multiplier Tubes (PMT) that have achieved ∼500ps FWHM Coincidence Time Resolution (CTR). A new device known as the Silicon PhotoMultiplier (SiPM) has the potential to overcome some of the limitations of the PMT. Therefore implementing a SiPM based TOF-PET scanner is of high interest. Recently Philips has introduced a TOF-PET scanner that uses digital Silicon PhotoMultipliers (d-SiPMs) which has a CTR of 350 ps. Here we will report on the timing performance of two Hamamatsu 3×3 mm{sup 2} analogue-SiPMs read out with the NINO ASIC: this is an ultra-fast amplifier/discriminator with a differential architecture. The differential architecture is very important since the single-ended readout uses the ground as the signal return; as the ground is also the reference level for the discriminators, the result is high crosstalk and degraded time resolution. However differential readout allows the scaling up from a single cell to a multi-cell device with no loss of time resolution; this becomes increasingly important for the highly segmented detectors that are being built today, both for particle and for medical instrumentation. We obtained excellent results for both the Single Photon Time Resolution (SPTR) and for the CTR using a LYSO crystal of 15 mm length. Such a crystal length has sufficient detection efficiency for 511 keV gammas to make an excellent PET device. The results presented here are proof that a TOF-PET detector with a CTR of 175 ps is indeed possible. This is the first step that defines the starting point of our SuperNINO project.

  6. Systematic study of new types of Hamamatsu MPPCs read out with the NINO ASIC

    International Nuclear Information System (INIS)

    Doroud, K.; Rodriguez, A.; Williams, M.C.S.; Yamamoto, K.; Zichichi, A.; Zuyeuski, R.

    2014-01-01

    Over the last decade there have been commercial TOF-PET scanners constructed using Photo-Multiplier Tubes (PMT) that have achieved ∼500ps FWHM Coincidence Time Resolution (CTR). A new device known as the Silicon PhotoMultiplier (SiPM) has the potential to overcome some of the limitations of the PMT. Therefore implementing a SiPM based TOF-PET scanner is of high interest. Recently Philips has introduced a TOF-PET scanner that uses digital Silicon PhotoMultipliers (d-SiPMs) which has a CTR of 350 ps. Here we will report on the timing performance of two Hamamatsu 3×3 mm 2 analogue-SiPMs read out with the NINO ASIC: this is an ultra-fast amplifier/discriminator with a differential architecture. The differential architecture is very important since the single-ended readout uses the ground as the signal return; as the ground is also the reference level for the discriminators, the result is high crosstalk and degraded time resolution. However differential readout allows the scaling up from a single cell to a multi-cell device with no loss of time resolution; this becomes increasingly important for the highly segmented detectors that are being built today, both for particle and for medical instrumentation. We obtained excellent results for both the Single Photon Time Resolution (SPTR) and for the CTR using a LYSO crystal of 15 mm length. Such a crystal length has sufficient detection efficiency for 511 keV gammas to make an excellent PET device. The results presented here are proof that a TOF-PET detector with a CTR of 175 ps is indeed possible. This is the first step that defines the starting point of our SuperNINO project

  7. A positron emission tomograph based on LSO-APD modules with a sampling ADC read-out system for a students' advanced laboratory course.

    Science.gov (United States)

    Schneider, Florian R; Mann, Alexander B; Konorov, Igor; Delso, Gaspar; Paul, Stephan; Ziegler, Sibylle I

    2012-06-01

    A one-day laboratory course on positron emission tomography (PET) for the education of physics students and PhD students in medical physics has been set up. In the course, the physical background and the principles of a PET scanner are introduced. Course attendees set the system in operation, calibrate it using a (22)Na point source and reconstruct different source geometries filled with (18)F. The PET scanner features an individual channel read-out of 96 lutetium oxyorthosilicate (LSO) scintillator crystals coupled to avalanche photodiodes (APD). The analog data of each APD are digitized by fast sampling analog to digital converters (SADC) and processed within field programmable gate arrays (FPGA) to extract amplitudes and time stamps. All SADCs are continuously sampling with a precise rate of 80MHz, which is synchronous for the whole system. The data is transmitted via USB to a Linux PC, where further processing and the image reconstruction are performed. The course attendees get an insight into detector techniques, modern read-out electronics, data acquisition and PET image reconstruction. In addition, a short introduction to some common software applications used in particle and high energy physics is part of the course. Copyright © 2011. Published by Elsevier GmbH.

  8. Synthesis of ent-BE-43547A1 reveals a potent hypoxia-selective anticancer agent and uncovers the biosynthetic origin of the APD-CLD natural products

    Science.gov (United States)

    Villadsen, Nikolaj L.; Jacobsen, Kristian M.; Keiding, Ulrik B.; Weibel, Esben T.; Christiansen, Bjørn; Vosegaard, Thomas; Bjerring, Morten; Jensen, Frank; Johannsen, Mogens; Tørring, Thomas; Poulsen, Thomas B.

    2017-03-01

    Tumour hypoxia is speculated to be a key driver of therapeutic resistance and metastatic dissemination. Consequently, the discovery of new potent agents that selectively target the hypoxic cell population may reveal new and untapped antitumour mechanisms. Here we demonstrate that the BE-43547 subclass of the APD-CLD (amidopentadienoate-containing cyclolipodepsipeptides) natural products possesses highly hypoxia-selective growth-inhibitory activity against pancreatic cancer cells. To enable this discovery, we have developed the first synthesis of the BE-43547-macrocyclic scaffold in 16 steps (longest linear sequence), which also allowed access to the full panel of relative stereoisomers and ultimately to the assignment of stereochemical configuration. Discrepancies between the spectroscopic signatures of the synthetic compounds with that originally reported for the BE-43547 members stimulated us to re-isolate the natural product from a BE-43547-producing microorganism during which we elucidated the biosynthetic gene clusters for the BE-43547 family as well as for all other known APD-CLDs. Our studies underline the exciting possibilities for the further development of the anticancer activities of these natural products.

  9. Seasonal variations of neuromotor development by 14 months of age: Hamamatsu Birth Cohort for mothers and children (HBC Study.

    Directory of Open Access Journals (Sweden)

    Kenji J Tsuchiya

    Full Text Available The present study aimed at investigating whether neuromotor development, from birth to 14 months of age, shows seasonal, cyclic patterns in association with months of birth. Study participants were 742 infants enrolled in the Hamamatsu Birth Cohort (HBC Study and followed-up from birth to the 14th month of age. Gross motor skills were assessed at the ages of 6, 10, and 14 months, using Mullen Scales of Early Learning. The score at each assessment was regressed onto a trigonometric function of months of birth, with an adjustment for potential confounders. Gross motor scores at the 6th and 10th months showed significant 1-year-cycle variations, peaking among March- and April-born infants, and among February-born infants, respectively. Changes in gross motor scores between the 10th and 14th months also showed a cyclic variation, peaking among July- and August-born infants. Due to this complementary effect, gross motor scores at the 14th month did not show seasonality. Neuromotor development showed cyclic seasonality during the first year of life. The effects brought about by month of birth disappeared around 1 year of age, and warmer months seemed to accelerate the neuromotor development.

  10. Joint CARE-ELAN, CARE-HHH-APD, and EUROTEV-WP3 Workshop on Electron Cloud Clearing

    CERN Document Server

    Scandale, Walter; Schulte, D; Zimmermann, F; Electron Cloud Effects and Technological Consequences; ECL2

    2007-01-01

    This report contains the Proceedings of the joint CARE-HHH-APD, CARE-ELAN, and EUROTEV-WP3 Mini-Workshop on 'Electron Cloud Clearing - Electron Cloud and Technical Consequences', "ECL2", held at CERN in Geneva, Switzerland, 1-2 March 2007). The ECL2 workshop explored novel technological remedies against electron-cloud formation in an accelerator beam pipe. A primary motivation for the workshop was the expected harmful electron-cloud effects in the upgraded LHC injectors and in future linear colliders, as well as recent beam observations in operating facilities like ANKA, CESR, KEKB, RHIC, and SPS. The solutions discussed at ECL2 included enamel-based clearing electrodes, slotted vacuum chambers, NEG coating, and grooves. Several of the proposed cures were assessed in terms of their clearing efficiency and the associated beam impedance. The workshop also reviewed new simulation tools like the 3D electron-ion build-up 'Faktor', modeling assumptions, analytical calculations, beam experiments, and laboratory meas...

  11. The Magnetar Model of the Superluminous Supernova GAIA16apd and the Explosion Jet Feedback Mechanism

    Energy Technology Data Exchange (ETDEWEB)

    Soker, Noam, E-mail: soker@physics.technion.ac.il [Department of Physics, Technion—Israel Institute of Technology, Haifa 32000 (Israel)

    2017-04-10

    Under the assumption that jets explode core collapse supernovae (CCSNe) in a negative jet feedback mechanism (JFM), this paper shows that rapidly rotating neutron stars are likely to be formed when the explosion is very energetic. Under the assumption that an accretion disk or an accretion belt around the just-formed neutron star launch jets and that the accreted gas spins-up the just-formed neutron star, I derive a crude relation between the energy that is stored in the spinning neutron star and the explosion energy. This relation is ( E {sub NS-spin}/ E {sub exp}) ≈ E {sub exp}/10{sup 52} erg; It shows that within the frame of the JFM explosion model of CCSNe, spinning neutron stars, such as magnetars, might have significant energy in super-energetic explosions. The existence of magnetars, if confirmed, such as in the recent super-energetic supernova GAIA16apd, further supports the call for a paradigm shift from neutrino-driven to jet-driven CCSN mechanisms.

  12. Time-of-flight resolution of scintillating counters with Burle 85001 microchannel plate photomultipliers in comparison with Hamamatsu R2083

    Energy Technology Data Exchange (ETDEWEB)

    Baturin, V. [Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Burkert, V. [Thomas Jefferson National Accelerator Facility, Newport News, Virginia 23606 (United States); Kim, W. [Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of)]. E-mail: wooyoung@jlab.org; Majewsky, S. [Thomas Jefferson National Accelerator Facility, Newport News, Virginia 23606 (United States); Park, K. [Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Popov, V. [Thomas Jefferson National Accelerator Facility, Newport News, Virginia 23606 (United States); Smith, E.S. [Thomas Jefferson National Accelerator Facility, Newport News, Virginia 23606 (United States); Son, D. [Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Stepanyan, S.S. [Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Zorn, C. [Thomas Jefferson National Accelerator Facility, Newport News, Virginia 23606 (United States)

    2006-06-15

    Improvements in the time resolution of the CEBAF Large Acceptance Spectrometer (CLAS) below {approx}50ps will be required for experiments using the planned upgraded accelerator facility at Jefferson Lab. The improved time resolution will allow particle identification using time-of-flight techniques to be used effectively up to the proposed operating energy of 12GeV. The challenge of achieving this time resolution over a relatively large area is compounded because the photomultipliers (PM) in the CLAS 'time-zero' scintillating counters must operate in very high magnetic fields. Therefore, we have studied the resolution of 'time-zero' prototypes with microchannel plate PMs 85001-501 from Burle. For reference and comparison, measurements were also made using the standard PMs R2083 from Hamamatsu using two timing methods. The cosmic ray method, which utilizes three identical scintillating counters (Bicron BC-408, 2x3x50cm{sup 3}) with PMs at the ends, yields {sigma}{sub R2083}=59.1+/-0.7ps. The location method of particles from a radiative source with known coordinates has been used to compare timing resolutions of R2083 and 85001-501. This method yields {sigma}{sub R2083}=59.5+/-0.7ps and it also provides an estimate of the number of primary photoelectrons. For the microchannel plate PM from Burle the method yields {sigma}{sub 85001}=130+/-4ps due to lower number of primary photoelectrons.

  13. Analysis of surface dark current dependent upon surface passivation in APD based on GaAs

    International Nuclear Information System (INIS)

    Song, Hong Joo; Roh, Cheong Hyun; Lee, Jun Ho; Choi, Hong Goo; Hahn, Cheol-Koo; Kim, Dong Ho; Park, Jung Ho

    2009-01-01

    In this paper, we investigated the dependence of reverse dark current on two types of surface passivation, one of which is polyimide and the other is SiN x , for InAs quantum dots/GaAs separate absorption, charge, multiplication avalanche photodiode (SACM APD). From the experimental results, we found that dark current was dominated by surface current, and not bulk current. It was also noted that SiN x passivation has a surface current that is lower by three to nine times in magnitude than that in polyimide passivation in the whole range of bias. To analyze the difference in dark current due to the passivation types, we propose the theoretical current components. This shows that the dark current of both passivation types is mainly composed of generation–recombination (G–R) and tunneling components, originating from the surface. However, each component has a different magnitude for passivation types, which can be explained by carrier concentration and trap density. The dependence of dark current on temperature shows the different behaviors between passivation types and supports a theoretical description of current components

  14. Consensus on the Definition of Advanced Parkinson’s Disease: A Neurologists-Based Delphi Study (CEPA Study

    Directory of Open Access Journals (Sweden)

    Maria-Rosario Luquin

    2017-01-01

    Full Text Available To date, no consensus exists on the key factors for diagnosing advanced Parkinson disease (APD. To obtain consensus on the definition of APD, we performed a prospective, multicenter, Spanish nationwide, 3-round Delphi study (CEPA study. An ad hoc questionnaire was designed with 33 questions concerning the relevance of several clinical features for APD diagnosis. In the first-round, 240 neurologists of the Spanish Movement Disorders Group participated in the study. The results obtained were incorporated into the questionnaire and both, results and questionnaire, were sent out to and fulfilled by 26 experts in Movement Disorders. Review of results from the second-round led to a classification of symptoms as indicative of “definitive,” “probable,” and “possible” APD. This classification was confirmed by 149 previous participating neurologists in a third-round, where 92% completely or very much agreed with the classification. Definitive symptoms of APD included disability requiring help for the activities of daily living, presence of motor fluctuations with limitations to perform basic activities of daily living without help, severe dysphagia, recurrent falls, and dementia. These results will help neurologists to identify some key factors in APD diagnosis, thus allowing users to categorize the patients for a homogeneous recognition of this condition.

  15. Inhibitory effects of Oenothera biennis (evening primrose) seed extract on Streptococcus mutans and S. mutans-induced dental caries in rats.

    Science.gov (United States)

    Matsumoto-Nakano, M; Nagayama, K; Kitagori, H; Fujita, K; Inagaki, S; Takashima, Y; Tamesada, M; Kawabata, S; Ooshima, T

    2011-01-01

    Oenothera biennis (evening primrose) seed extract (OBSE) is known to contain polyphenols, which may possess antioxidant activities. Polyphenols extracted from several plants are reported to exhibit cariostatic activities by inhibiting mutans streptococcus growth and glucosyltransferase activities. The purpose of the present study was to examine the inhibitory effects of OBSE on the development of dental caries, both in vitro and in vivo. OBSE was investigated for its inhibitory effects on cellular aggregation, hydrophobicity, sucrose-dependent adherence and insoluble glucan synthesis. Furthermore, biofilm formation was examined in the presence of OBSE, using confocal microscopic imaging. An animal experiment was also performed to examine the in vivo effects. OBSE induced a strong aggregation of Streptococcus mutans MT8148 cells, while cell surface hydrophobicity was decreased by approximately 90% at a concentration of 0.25 mg/ml. The sucrose-dependent adherence of the MT8148 cells was also reduced by addition of OBSE, with a reduction rate of 73% seen at a concentration of 1.00 mg/ml. Additionally, confocal microscopic observations revealed the biofilm development phase to be remarkably changed in the presence of OBSE. Furthermore, insoluble glucan synthesis was significantly reduced when OBSE was present at concentrations greater than 0.03 mg/ml. In an animal experiment, the caries scores in rats given OBSE (0.05 mg/ml in drinking water) were significantly lower than those in rats given water without OBSE. Our results indicate that OBSE has inhibitory activity on dental caries. 2011 S. Karger AG, Basel.

  16. Four-layer depth-of-interaction PET detector for high resolution PET using a multi-pixel S8550 avalanche photodiode

    Energy Technology Data Exchange (ETDEWEB)

    Nishikido, Fumihiko, E-mail: funis@nirs.go.j [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Inadama, Naoko [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Oda, Ichiro [Shimadzu Corporation, Nishinokyo Kuwabaracho 1 Nakagyo-ku, Kyoto-shi, Kyoto 604-8511 (Japan); Shibuya, Kengo; Yoshida, Eiji; Yamaya, Taiga [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Kitamura, Keishi [Shimadzu Corporation, Nishinokyo Kuwabaracho 1 Nakagyo-ku, Kyoto-shi, Kyoto 604-8511 (Japan); Murayama, Hideo [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan)

    2010-09-21

    Avalanche photodiodes (APDs) are being used as photodetectors in positron emission tomography (PET) because they have many advantages over photomultipliers (PMTs) typically used in PET detectors. We have developed a PET detector that consists of a multi-pixel APD and a 6x6x4 array of 1.46x1.46 mm{sup 2}x4.5 m LYSO crystals for a small animal PET scanner. The detector can identify four-layer depth of interaction (DOI) with a position-sensitive APD coupled to the backside of a crystal array by just an optimized reflector arrangement. Since scintillation lights are shared among many pixels by the method, weaker signals in APD pixels far from the interacting crystals are affected by noise. To evaluate the performance of the four-layer DOI detector with the APD and the influence of electrical noise on our method, we constructed a prototype DOI detector and tested its performance. We found, except for crystal elements on the edge of the crystal array, all crystal elements could be identified from the 2D position histogram. An energy resolution of 16.9% was obtained for the whole crystal array of the APD detector. The results of noise dependence of detector performances indicated that the DOI detector using the APD could achieve sufficient performance even when using application-specific integrated circuits.

  17. Four-layer depth-of-interaction PET detector for high resolution PET using a multi-pixel S8550 avalanche photodiode

    International Nuclear Information System (INIS)

    Nishikido, Fumihiko; Inadama, Naoko; Oda, Ichiro; Shibuya, Kengo; Yoshida, Eiji; Yamaya, Taiga; Kitamura, Keishi; Murayama, Hideo

    2010-01-01

    Avalanche photodiodes (APDs) are being used as photodetectors in positron emission tomography (PET) because they have many advantages over photomultipliers (PMTs) typically used in PET detectors. We have developed a PET detector that consists of a multi-pixel APD and a 6x6x4 array of 1.46x1.46 mm 2 x4.5 m LYSO crystals for a small animal PET scanner. The detector can identify four-layer depth of interaction (DOI) with a position-sensitive APD coupled to the backside of a crystal array by just an optimized reflector arrangement. Since scintillation lights are shared among many pixels by the method, weaker signals in APD pixels far from the interacting crystals are affected by noise. To evaluate the performance of the four-layer DOI detector with the APD and the influence of electrical noise on our method, we constructed a prototype DOI detector and tested its performance. We found, except for crystal elements on the edge of the crystal array, all crystal elements could be identified from the 2D position histogram. An energy resolution of 16.9% was obtained for the whole crystal array of the APD detector. The results of noise dependence of detector performances indicated that the DOI detector using the APD could achieve sufficient performance even when using application-specific integrated circuits.

  18. Studies on multiplication effect of noises of PPD, and a proposal of a new structure to improve the performance

    Energy Technology Data Exchange (ETDEWEB)

    Oide, H., E-mail: oide@icepp.s.u-tokyo.ac.j [Department of Physics, University of Tokyo, 7-3-1 Hongo Bunkyo, Tokyo 113-0033 (Japan); Murase, T.; Otono, H. [Department of Physics, University of Tokyo, 7-3-1 Hongo Bunkyo, Tokyo 113-0033 (Japan); Yamashita, S. [ICEPP, University of Tokyo, 7-3-1 Hongo Bunkyo, Tokyo 113-0033 (Japan)

    2010-11-01

    Pixelated photon detectors (PPDs) are arrayed APDs operated in Geiger-mode. Multi-pixel photon counter (MPPC) is a PPD produced by Hamamatsu Photonics K.K. We performed measurement of total noise rate, random noise rate, after-pulsing, crosstalk, and relative photon detection efficiency for a 1600 px MPPC. The explosive increase of total noise rate to over-voltage is able to be understood of multiplication effect of after-pulsing and crosstalk. Considering the electric field structure of MPPC (p-on-n type) and Geiger-efficiency as a function of the position of initial pair creation, these characteristics are all able to be understood. One suggestion for p-on-n type PPD from these results is narrowing the depletion layer below the multiplication layer to reduce random noise and after-pulsing. Another proposal is to put additional buffer capacitance parallel to the diode to accomplish higher gain with lower over-voltage simultaneously with lower noise rate.

  19. Studies on multiplication effect of noises of PPD, and a proposal of a new structure to improve the performance

    International Nuclear Information System (INIS)

    Oide, H.; Murase, T.; Otono, H.; Yamashita, S.

    2010-01-01

    Pixelated photon detectors (PPDs) are arrayed APDs operated in Geiger-mode. Multi-pixel photon counter (MPPC) is a PPD produced by Hamamatsu Photonics K.K. We performed measurement of total noise rate, random noise rate, after-pulsing, crosstalk, and relative photon detection efficiency for a 1600 px MPPC. The explosive increase of total noise rate to over-voltage is able to be understood of multiplication effect of after-pulsing and crosstalk. Considering the electric field structure of MPPC (p-on-n type) and Geiger-efficiency as a function of the position of initial pair creation, these characteristics are all able to be understood. One suggestion for p-on-n type PPD from these results is narrowing the depletion layer below the multiplication layer to reduce random noise and after-pulsing. Another proposal is to put additional buffer capacitance parallel to the diode to accomplish higher gain with lower over-voltage simultaneously with lower noise rate.

  20. LASER ABLATION-INDUCTIVELY COUPLED PLASMA-ATOMIC EMISSION SPECTROSCOPY STUDY AT THE 222-S LABORATORY USING HOT-CELL GLOVE BOX PROTOTYPE SYSTEM

    International Nuclear Information System (INIS)

    Seidel, C.M.; Jain, J.; Owens, J.W.

    2009-01-01

    This report describes the installation, testing, and acceptance of the Waste Treatment and Immobilization Plant (WTP) procured laser ablation-inductively coupled plasma-atomic emission spectroscopy (LA-ICP-AES) system for remotely analyzing high-level waste (HLW) samples in a hot cell environment. The work was completed by the Analytical Process Development (APD) group in accordance with Task Order 2005-003; ATS MP 1027, Management Plan for Waste Treatment Plant Project Work Performed by Analytical Technical Services. The APD group at the 222-S Laboratory demonstrated acceptable turnaround time (TAT) and provide sufficient data to assess sensitivity, accuracy, and precision of the LA-ICP-AES method

  1. CME 8148 ONLINE.indd

    African Journals Online (AJOL)

    104, No. 4. It was not a given that I would live. It was not a given that I would walk. It was not ... subsequent odour may cause isolation in the home or workplace. .... alleviating the stress on the family. ... benefit from good schooling, owing to the.

  2. Regulation of Recombination between gtfB/gtfC Genes in Streptococcus mutans by Recombinase A

    Directory of Open Access Journals (Sweden)

    Satoko Inagaki

    2013-01-01

    Full Text Available Streptococcus mutans produces 3 types of glucosyltransferases (GTFs, whose cooperative action is essential for cellular adhesion. The recombinase A (RecA protein is required for homologous recombination. In our previous study, we isolated several strains with a smooth colony morphology and low GTF activity, characteristics speculated to be derived from the GTF fusions. The purpose of the present study was to investigate the mechanism of those fusions. S. mutans strain MT8148 was grown in the presence of recombinant RecA (rRecA protein, after which smooth colonies were isolated. The biological functions and sequences of the gtfB and gtfC genes of this as well as other clinical strains were determined. The sucrose-dependent adherence rates of those strains were reduced as compared to that of MT8148. Determination of the sequences of the gtfB and gtfC genes showed that an approximately 3500 bp region was deleted from the area between them. Furthermore, expression of the recA gene was elevated in those strains as compared to MT8148. These results suggest that RecA has an important role in fusions of gtfB and gtfC genes, leading to alteration of colony morphology and reduction in sucrose-dependent adhesion.

  3. Behaviour of Belle II ARICH Hybrid Avalanche Photo-Detector in magnetic field

    Science.gov (United States)

    Kindo, H.; Adachi, I.; Dolenec, R.; Hataya, K.; Iori, S.; Iwata, S.; Kakuno, H.; Kataura, R.; Kawai, H.; Kobayashi, T.; Konno, T.; Korpar, S.; Kriz˘an, P.; Kumita, T.; Mrvar, M.; Nishida, S.; Ogawa, K.; Ogawa, S.; Pestotnik, R.; Šantelj, L.; Sumiyoshi, T.; Tabata, M.; Yonenaga, M.; Yusa, Y.

    2017-12-01

    The proximity-focusing Aerogel Ring-Imaging Cherenkov detector (ARICH) has been designed to separate kaons from pions in the forward end-cap of the Belle II spectrometer. The detector will be placed in 1.5 T magnetic field and must have immunity to it. In ARICH R&D, we solve the problem with new equipment called Hybrid Avalanche Photo-Detector (HAPD) which developed by Hamamatsu Photonics. Recently the production of about 500 HAPDs was completed. We test HAPDs in magnetic field in KEK. We found some HAPDs have significant amount of dead time, which reaches up to 30% in the worst case. The dead time is caused by very large (more than 10,000 times larger than a single photon signal) and frequent (∼5 Hz) signals, which make electronics paralysed. The huge signals are observed in about 30% of HAPDs. To identify the origin and understand the mechanism, we perform some extra test of HAPDs. We find a strange dependence of the huge signals to the APD bias voltage. If we reduce the bias voltage applied to one of the 4 APDs by 10 V, the frequency of the huge signals is much reduced. On the other hand, if we reduce the voltage of all the 4 HAPDs, huge signals do not decrease, or even increase in some case. We also find the huge signals seems to be related to the vacuum inside HAPD. We present about the observation of the huge signals of HAPDs in the magnetic field, and our strategy to manage it.

  4. CARE-HHH-APD Workshop on Finalizing the Roadmap for the Upgrade of the CERN and GSI Accelerator Complex

    CERN Document Server

    Zimmermann, Frank; BEAM'07; BEAM 2007; Finalizing the Roadmap for the Upgrade of the LHC and GSI Accelerator Complex

    2008-01-01

    This report contains the Proceedings of the CARE-HHH-APD Event BEAM’07, “Finalizing the Roadmap for the Upgrade of the CERN & GSI Accelerator Complex,” which was held at CERN in Geneva, Switzerland, from 1 to 5 October 2007. BEAM’07 was primarily devoted to beam dynamics limitations for the two, or three, alternative baseline scenarios of the LHC luminosity upgrade and to critical design choices for the upgrade of the LHC injector complex at CERN and for the FAIR complex at GSI. It comprised five parts: (1) a Mini-Workshop on LHC+ Beam Performance, (2) a CERN-GSI Meeting on Collective Effects, (3) the Francesco Ruggiero Memorial Symposium, (4) a Mini-Workshop on the LHC Injectors Upgrade, and (5) the BEAM’07 Summaries. Topics addressed in the first mini-workshop of BEAM’07 ranged from the luminosity performance reach of the upgraded LHC in different scenarios, over the generation and stability of the future LHC beams, the turnaround time, beam–beam effects, luminosity levelling methods, and ...

  5. Measurement of the time resolution of small SiPM-based scintillation counters

    Science.gov (United States)

    Kravchenko, E. A.; Porosev, V. V.; Savinov, G. A.

    2017-12-01

    In this research, we evaluated the timing resolution of SiPM-based scintillation detector on a 1-GeV electron beam "extracted" from VEPP-4M. We tested small scintillation crystals of pure CsI, YAP, LYSO, and LFS-3 with HAMAMATSU S10362-33-025C and S13360-3050CS. The CsI scintillator together with HAMAMATSU S13360-3050CS demonstrated the best results. Nevertheless, the achieved time resolution of ~80 ps (RMS) relates mainly to the photodetector itself. It makes the silicon photomultiplier an attractive candidate to replace other devices in applications where sub-nanosecond accuracy is required.

  6. A detector insert based on continuous scintillators for hybrid MR–PET imaging of the human brain

    Energy Technology Data Exchange (ETDEWEB)

    Rato Mendes, P., E-mail: pedro.rato@ciemat.es [CIEMAT, Avenida Complutense 40, 28040 Madrid (Spain); Cuerdo, R.; Sarasola, I.; García de Acilu, P.; Navarrete, J.; Vela, O.; Oller, J.C.; Cela, J.M. [CIEMAT, Avenida Complutense 40, 28040 Madrid (Spain); Núñez, L.; Pastrana, M. [Hospital Universitario Puerta de Hierro Majadahonda, Manuel de Falla 1, 28222 Majadahonda (Spain); Romero, L.; Willmott, C. [CIEMAT, Avenida Complutense 40, 28040 Madrid (Spain)

    2013-02-21

    We are developing a positron emission tomography (PET) insert for existing magnetic resonance (MR) equipment, aiming at hybrid MR–PET imaging. Our detector block design is based on trapezoid-shaped LYSO:Ce monolithic scintillators coupled to magnetically compatible Hamamatsu S8550-02 silicon avalanche photodiode (APD) matrices with a dedicated ASIC front-end readout from GammaMedica-Ideas (Fornebu, Norway). The detectors are position sensitive, capable of determining the incidence point of 511 keV gammas with an intrinsic spatial resolution on the order of 2 mm by means of supervised learning neural-network (NN) algorithms. These algorithms, apart from providing continuous coordinates, are also intrinsically corrected for depth of interaction effects and thus parallax-free. Recently we have implemented an advanced prototype featuring two heads with four detector blocks each and final front-end and readout electronics, improving the spatial resolution of reconstructed point source images down to 1.7 mm full width at half maximum (FWHM). Presently we are carrying out operational tests of components and systems under magnetic fields using a 3 T MR scanner. In this paper we present a description of our project, a summary of the results obtained with laboratory prototypes, and the strategy to build and install the complete system at the nuclear medicine department of a collaborating hospital.

  7. A detector insert based on continuous scintillators for hybrid MR–PET imaging of the human brain

    International Nuclear Information System (INIS)

    Rato Mendes, P.; Cuerdo, R.; Sarasola, I.; García de Acilu, P.; Navarrete, J.; Vela, O.; Oller, J.C.; Cela, J.M.; Núñez, L.; Pastrana, M.; Romero, L.; Willmott, C.

    2013-01-01

    We are developing a positron emission tomography (PET) insert for existing magnetic resonance (MR) equipment, aiming at hybrid MR–PET imaging. Our detector block design is based on trapezoid-shaped LYSO:Ce monolithic scintillators coupled to magnetically compatible Hamamatsu S8550-02 silicon avalanche photodiode (APD) matrices with a dedicated ASIC front-end readout from GammaMedica-Ideas (Fornebu, Norway). The detectors are position sensitive, capable of determining the incidence point of 511 keV gammas with an intrinsic spatial resolution on the order of 2 mm by means of supervised learning neural-network (NN) algorithms. These algorithms, apart from providing continuous coordinates, are also intrinsically corrected for depth of interaction effects and thus parallax-free. Recently we have implemented an advanced prototype featuring two heads with four detector blocks each and final front-end and readout electronics, improving the spatial resolution of reconstructed point source images down to 1.7 mm full width at half maximum (FWHM). Presently we are carrying out operational tests of components and systems under magnetic fields using a 3 T MR scanner. In this paper we present a description of our project, a summary of the results obtained with laboratory prototypes, and the strategy to build and install the complete system at the nuclear medicine department of a collaborating hospital

  8. Low energy γ- γ and e{sup −}- γ PAC measurements using APDs and the probe nuclei {sup 83}Rb({sup 83}Kr) and {sup 83m}Kr({sup 83}Kr)

    Energy Technology Data Exchange (ETDEWEB)

    Arenz, M., E-mail: arenz@hiskp.uni-bonn.de; Vianden, R., E-mail: vianden@hiskp.uni-bonn.de [Universität Bonn, Helmholtz-Institut für Strahlen- und Kernphysik (Germany)

    2016-12-15

    In the field of Perturbed Angular Correlation (PAC) measurements Avalanche Photo Diodes (APD) are rarely used, despite their favourable properties for fast counting purposes at low energies. This work demonstrates their application in combination with a simple and cheap custom build voltage sensitive preamplifier module. Using the PAC nuclei {sup 83}Rb({sup 83}Kr) and {sup 83m}Kr({sup 83}Kr), the time resolution of the set-up is analysed and the feasibility of precise timing measurements is shown.

  9. Author Details

    African Journals Online (AJOL)

    Paul, Fintan. Vol 5, No 1 (2017) - Articles Government expenditure and economic growth nexus: Wagner's law or Keynesian hypothesis for Tanzania? Abstract PDF. ISSN: 1821-8148. AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's · More about AJOL · AJOL's ...

  10. Large area avalanche MRS-photodiodes for nuclear spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Ermalitski, F A; Zalesski, V B

    1996-12-31

    Problems of application of avalanche photodiodes (APD) in readout systems of nuclear spectrometers are considered. APD`s with a large sensitive area of a diameter 1-5 mm and a high multiplication coefficient 200-1000 are created. MPS-photodiodes provide for the energy resolution 80% at temperature 231 K for detecting gamma-quanta with energy 662 keV. 4 refs.

  11. 2.3 Gbit/s underwater wireless optical communications using directly modulated 520 nm laser diode

    KAUST Repository

    Oubei, Hassan M.

    2015-07-30

    We experimentally demonstrate a record high-speed underwater wireless optical communication (UWOC) over 7 m distance using on-off keying non-return-to-zero (OOK-NRZ) modulation scheme. The communication link uses a commercial TO-9 packaged pigtailed 520 nm laser diode (LD) with 1.2 GHz bandwidth as the optical transmitter and an avalanche photodiode (APD) module as the receiver. At 2.3 Gbit/s transmission, the measured bit error rate of the received data is 2.23×10−4, well below the forward error correction (FEC) threshold of 2×10−3 required for error-free operation. The high bandwidth of the LD coupled with high sensitivity APD and optimized operating conditions is the key enabling factor in obtaining high bit rate transmission in our proposed system. To the best of our knowledge, this result presents the highest data rate ever achieved in UWOC systems thus far.

  12. Test of the HAPD light sensor for the Belle II Aerogel RICH

    Science.gov (United States)

    Yusa, Y.; Adachi, I.; Dolenec, R.; Hayata, K.; Iori, S.; Iwata, S.; Kakuno, H.; Kataura, R.; Kawai, H.; Kindo, H.; Kobayashi, T.; Korpar, S.; Krizan, P.; Kumita, T.; Mrvar, M.; Nishida, S.; Ogawa, K.; Pestotnik, R.; Santelj, L.; Sumiyoshi, T.; Tabata, M.; Yonenaga, M.

    2017-12-01

    The Aerogel Ring-Imaging Cherenkov detector (ARICH) is being installed in the endcap region of Belle II spectrometer to identify particles from B meson decays by detecting the Cherenkov ring image from aerogel radiators. To detect single photons, high-sensitive photon detector which has wide effective area (∼70 mm × 70 mm), a Hybrid Avalanche Photo Detector (HAPD), has been developed in a collaboration with Hamamatsu K.K. The HAPD consists of hybrid structure of a vacuum tube and an avalanche photodiode (APD). It can be operated in 1.5 T magnetic field of the spectrometer and withstands the radiation levels expected in the Belle II experiment. There are two steps of electric pulse amplification: acceleration of photo-electron in electric field in the vacuum tube part and electron avalanche in the APD part resulting in total gain of order 105. For the ARICH, we use 420 HAPDs in total. Before installing them, we performed quality assessment studies such as measurements of dark current, noise level, signal-to-noise ratio and two-dimensional scan with laser illumination. We also measured quantum efficiency of the photocathode. During the HAPD performance tests in the magnetic field, we observed very large signal pulses which cause long dead time of the readout electronics in some of the HAPDs. We have carried out a number of studies to understand this phenomenon, and have found a way to mitigate it and suppress the degradation of the ARICH performance. In this report, we will show a summary of the HAPD performance and quality assessment measurements including validation in the magnetic field for all of the HAPDs manufactured for the ARICH in the Belle II.

  13. Author Details

    African Journals Online (AJOL)

    Mutalemwa, DK. Vol 3, No 1 (2015) - Articles Engaging the Tanzanian Diaspora in National Development: What Do We Know and What are the Gaps? Abstract PDF. ISSN: 1821-8148. AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's · More about AJOL · AJOL's ...

  14. Progress in low light-level InAs detectors- towards Geiger-mode detection

    Science.gov (United States)

    Tan, Chee Hing; Ng, Jo Shien; Zhou, Xinxin; David, John; Zhang, Shiyong; Krysa, Andrey

    2017-05-01

    InAs avalanche photodiodes (APDs) can be designed such that only electrons are allowed to initiate impact ionization, leading to the lowest possible excess noise factor. Optimization of wet chemical etching and surface passivation produced mesa APDs with bulk dominated dark current and responsivity that are comparable and higher, respectively, than a commercial InAs detector. Our InAs electron-APDs also show high stability with fluctuation of 0.1% when operated at a gain of 11.2 over 60 s. These InAs APDs can detect very weak signal down to 35 photons per pulse. Fabrication of planar InAs by Be implantation produced planar APDs with bulk dominated dark current. Annealing at 550 °C was necessary to remove implantation damage and to activate Be dopants. Due to minimal diffusion of Be, thick depletion of 8 μm was achieved. Since the avalanche gain increases exponentially with the thickness of avalanche region, our planar APD achieved high gain > 300 at 200 K. Our work suggest that both mesa and planar InAs APDs can exhibit high gain. When combined with a suitable preamplifier, single photon detection using InAs electron-APDs could be achieved.

  15. Acquired perforating dermatosis: a report of 8 cases.

    Science.gov (United States)

    González-Lara, L; Gómez-Bernal, S; Vázquez-López, F; Vivanco-Allende, B

    2014-01-01

    Acquired perforating dermatosis (APD) is an uncommon disease characterized by lesions exhibiting transepidermal elimination of collagen or elastic fibers. APD affects adults and is associated with systemic diseases, mainly diabetes mellitus and renal failure. We present 8 cases of APD. Seven patients had concomitant diabetes mellitus with or without chronic renal failure, and 1 had alcoholic cirrhosis. In the patients with chronic renal failure, the onset of APD coincided with transient worsening of renal function. The mean increase in creatinine concentrations above baseline was 1.14mg/dL. Acute deterioration of renal function may be involved in APD. Further studies are needed to investigate this association. Copyright © 2013 Elsevier España, S.L. y AEDV. All rights reserved.

  16. Avalanche photodiodes for ISABELLE detectors

    International Nuclear Information System (INIS)

    Strand, R.C.

    1979-01-01

    At ISABELLE some requirements for detecting bursts of photons are not met by standard photomultiplier tubes. The characteristics of immunity to magnetic fields, small size (few mm), low power consumption (approx. 100 mW), insensitivity to optical overloads, and wide dynamic range (approx. 60 dB) are achieved with difficulty, if at all, with PMTs. These are characteristics of the solid state avalanche photodiode (APD), the preferred detector for light-wave communications. Successful field tests with APD detectors stimulated the design of standard optical-fiber communication systems to replace wire carriers by the early 1980's. In other characteristics, i.e., counting rate, pulse-height resolution, effective quantum efficiency, detection efficiency, and reliability, bare APDs are equivalent to standard PMTs. APDs with currently available amplifiers cannot resolve single photoelectrons but they could provide reasonable detection efficiencies and pulse-height resolution for packets of approx. > 100 photons. Commercially available APDs can cost up to 100 times as much as PMTs per active area, but they are potentially much cheaper. Six topics are discussed: (1) detectors for light-wave communication and detectors for particles, (2) avalanche photodiodes, (3) commercially available APDs, (4) dynamic response of PMTs and bare APDs, (5) photon counting with cold APDs, and (6) conclusions and recommendations

  17. Ante partum depression and husband’s mental problem increased risk maternity blues

    Directory of Open Access Journals (Sweden)

    R. I. Ismail

    2006-06-01

    Full Text Available Maternity blues disorder (MB is common, and it is usually undiagnosed. This study to identify several risk factors related to MB. Subjects were pregnant women who had antenatal and delivery at the Persahabatan Hospital (RSP Jakarta from 1 November 1999 to 15 August 2001. Consecutive sampling and was followed-up until two-week postpartum. Those who ever had psychiatric disorders (schizophrenia or other psychotic disorders were excluded. MB and ante partum depression (APD detected by using Edinburgh Postnatal Depression Scale (EPDS. Husband’s mental status based on Symptom Check List-90 (SCL-90 respectively. Among 580 subjects, 25% suffering from MB. Compared with those who did not have APD, those who experienced it had more than three-fold increased risk to be MB [adjusted hazard ratio (aHR = 3.57; 95% confidence interval (CI = 2.54;5.03]. Those who had not healthy baby on the first 5 days afterbirth than who had healthy baby had twice increased risk to be MB (aHR = 2.21; 95% CI = 1.34 ; 3.66. Who had husband with problem in mental health had 1.9 increased risk to be MB (aHR = 1.91; 95% CI = 1.36 ; 2.68. Stress during pregnancy had 1.6 increased risk to be MB (aHR = 1.59; 95% CI = 1.14 ; 2.25. To control MB, special attention should be paid to women who had APD history, who had unhealthy baby on 5 first days afterbirth, who had husbands’ mental health problems, and who had stress during pregnancy. (Med J Indones 2006; 15:74-80Keywords: ante partum, maternity blues, depression, mental problem

  18. Studies on multiplication effect of noises of PPDs, and a proposal of a new structure to improve the performance

    International Nuclear Information System (INIS)

    Oide, H.; Murase, T.; Otono, H.; Yamashita, S.

    2010-01-01

    Pixelated Photon Detectors (PPDs) are arrayed APDs operated in Geiger-mode. Multi-Pixel Photon Counter (MPPC) is a PPD produced by Hamamatsu Photonics K.K. Test of dark noise rate of a 1600 pixel MPPC as a function of over-voltage at room temperature indicates that the over-voltage is limited up to a few volts because of explosive increase of noise rate. The over-voltage dependence of random noise rate is nevertheless mostly linear. We confirmed this is due to multiplication effect of noises because of after-pulsing and crosstalk. Over-voltage dependence of random noise and photon detection efficiency are qualitatively different. Considering the electric field structure of MPPC (p-on-n type) and Geiger-efficiency as a function of the position of initial pair creation, these characteristics are possible to be understood. One suggestion for p-on-n type PPD from these results is narrowing the depletion layer below the multiplication layer to reduce random noise and after-pulsing. Another proposal is to put additional buffer capacitance parallel to the diode to accomplish higher gain with lower over-voltage simultaneously with lower noise rate.

  19. Studies on multiplication effect of noises of PPDs, and a proposal of a new structure to improve the performance

    Energy Technology Data Exchange (ETDEWEB)

    Oide, H., E-mail: oide@icepp.s.u-tokyo.ac.j [Department of Physics, University of Tokyo, 7-3-1, Hongo, Bunkyo, Tokyo (Japan); Murase, T.; Otono, H. [Department of Physics, University of Tokyo, 7-3-1, Hongo, Bunkyo, Tokyo (Japan); Yamashita, S. [ICEPP, University of Tokyo, 7-3-1, Hongo, Bunkyo, Tokyo (Japan)

    2010-01-21

    Pixelated Photon Detectors (PPDs) are arrayed APDs operated in Geiger-mode. Multi-Pixel Photon Counter (MPPC) is a PPD produced by Hamamatsu Photonics K.K. Test of dark noise rate of a 1600 pixel MPPC as a function of over-voltage at room temperature indicates that the over-voltage is limited up to a few volts because of explosive increase of noise rate. The over-voltage dependence of random noise rate is nevertheless mostly linear. We confirmed this is due to multiplication effect of noises because of after-pulsing and crosstalk. Over-voltage dependence of random noise and photon detection efficiency are qualitatively different. Considering the electric field structure of MPPC (p-on-n type) and Geiger-efficiency as a function of the position of initial pair creation, these characteristics are possible to be understood. One suggestion for p-on-n type PPD from these results is narrowing the depletion layer below the multiplication layer to reduce random noise and after-pulsing. Another proposal is to put additional buffer capacitance parallel to the diode to accomplish higher gain with lower over-voltage simultaneously with lower noise rate.

  20. Performance and quality control of Clear-PEM detector modules

    International Nuclear Information System (INIS)

    Amaral, Pedro; Carrico, Bruno; Ferreira, Miguel; Moura, Rui; Ortigao, Catarina; Rodrigues, Pedro; Da Silva, Jose C.; Trindade, Andreia; Varela, Joao

    2007-01-01

    Clear-PEM is a dedicated PET scanner for breast and axilla cancer diagnosis, under development within the framework of the Crystal Clear Collaboration at CERN, aiming at the detection of tumors down to 2 mm in diameter. The camera consists of two planar detector heads with active dimensions 16.0x14.5 cm 2 . Each head has 96 Clear-PEM detector modules consisting of 32 LYSO:Ce pixels with dimensions 2x2x20 mm 3 packed in a 4x8 BaSO 4 reflector matrix compressed between two Hamamatsu S8550 APD arrays in a double-readout configuration for Depth-of-Interaction (DoI) determination. The modules are individually measured and characterized before being grouped into Supermodules (comprised of 24 modules). Measured properties include photo-peak position, relative gain dispersion, energy resolution, cross-talk and DoI resolution. Optical inspection of matrices was also performed with the aid of a microscope, to search for pixel misalignments and matrix defects. Modules' performance was thoroughly evaluated with a 511 keV collimated beam to exactly determine DoI resolution. In addition, a fast quality control (QC) procedure using flood irradiations from a 137 Cs source was applied systematically. The overall performance of the 24 detector modules complies with the design goals of the Clear-PEM detector, showing energy resolution around 15%, DoI resolution of about 2 mm and gain dispersion among pixels of 15%

  1. Adaptive Priority-Based Downlink Scheduling for WiMAX Networks

    OpenAIRE

    Wu, Shih-Jung; Huang, Shih-Yi; Huang, Kuo-Feng

    2012-01-01

    Supporting quality of service (QoS) guarantees for diverse multimedia services are the primary concerns for WiMAX (IEEE 802.16) networks. A scheduling scheme that satisfies QoS requirements has become more important for wireless communications. We propose a downlink scheduling scheme called adaptive priority-based downlink scheduling (APDS) for providing QoS guarantees in IEEE 802.16 networks. APDS comprises two major components: priority assignment and resource allocation. Different service-...

  2. Flecainide attenuates rate adaptation of ventricular repolarization in guinea-pig heart

    DEFF Research Database (Denmark)

    Osadchii, Oleg E.

    2016-01-01

    examined flecainide effect on adaptation of the QT interval and ventricular action potential duration (APD) to abrupt reductions of the cardiac cycle length. DESIGN: ECG and ventricular epicardial and endocardial monophasic APD were recorded in isolated, perfused guinea-pig heart preparations upon...... a sustained cardiac acceleration (rapid pacing for 30 s), and following a single perturbation of the cycle length evoked by extrasystolic stimulation. RESULTS: Sustained increase in heart rate was associated with progressive bi-exponential shortening of the QT interval and APD. Flecainide prolonged...

  3. Spatial correlation of action potential duration and diastolic dysfunction in transgenic and drug-induced LQT2 rabbits.

    Science.gov (United States)

    Odening, Katja E; Jung, Bernd A; Lang, Corinna N; Cabrera Lozoya, Rocio; Ziupa, David; Menza, Marius; Relan, Jatin; Franke, Gerlind; Perez Feliz, Stefanie; Koren, Gideon; Zehender, Manfred; Bode, Christoph; Brunner, Michael; Sermesant, Maxime; Föll, Daniela

    2013-10-01

    Enhanced dispersion of action potential duration (APD) is a major contributor to long QT syndrome (LQTS)-related arrhythmias. To investigate spatial correlations of regional heterogeneities in cardiac repolarization and mechanical function in LQTS. Female transgenic LQTS type 2 (LQT2; n = 11) and wild-type littermate control (LMC) rabbits (n = 9 without E4031 and n = 10 with E4031) were subjected to phase contrast magnetic resonance imaging to assess regional myocardial velocities. In the same rabbits' hearts, monophasic APDs were assessed in corresponding segments. In LQT2 and E4031-treated rabbits, APD was longer in all left ventricular segments (P < .01) and APD dispersion was greater than that in LMC rabbits (P < .01). In diastole, peak radial velocities (Vr) were reduced in LQT2 and E4031-treated compared to LMC rabbits in LV base and mid (LQT2: -3.36 ± 0.4 cm/s, P < .01; E4031-treated: -3.24 ± 0.6 cm/s, P < .0001; LMC: -4.42 ± 0.5 cm/s), indicating an impaired diastolic function. Regionally heterogeneous diastolic Vr correlated with APD (LQT2: correlation coefficient [CC] 0.38, P = .01; E4031-treated: CC 0.42, P < .05). Time-to-diastolic peak Vr were prolonged in LQT2 rabbits (LQT2: 196.8 ± 2.9 ms, P < .001; E4031-treated: 199.5 ± 2.2 ms, P < .0001, LMC 183.1 ± 1.5), indicating a prolonged contraction duration. Moreover, in transgenic LQT2 rabbits, diastolic time-to-diastolic peak Vr correlated with APD (CC 0.47, P = .001). In systole, peak Vr were reduced in LQT2 and E4031-treated rabbits (P < .01) but longitudinal velocities or ejection fraction did not differ. Finally, random forest machine learning algorithms enabled a differentiation between LQT2, E4031-treated, and LMC rabbits solely based on "mechanical" magnetic resonance imaging data. The prolongation of APD led to impaired diastolic and systolic function in transgenic and drug-induced LQT2 rabbits. APD correlated with regional diastolic dysfunction, indicating that LQTS is not purely an

  4. Minimal Clinically Important Difference in Parkinson’s Disease as Assessed in Pivotal Trials of Pramipexole Extended Release

    Directory of Open Access Journals (Sweden)

    Robert A. Hauser

    2014-01-01

    Full Text Available Background. The minimal clinically important difference (MCID is the smallest change in an outcome measure that is meaningful for patients. Objectives. To calculate the MCID for Unified Parkinson’s Disease Rating Scale (UPDRS scores in early Parkinson’s disease (EPD and for UPDRS scores and “OFF” time in advanced Parkinson’s disease (APD. Methods. We analyzed data from two pivotal, double-blind, parallel-group trials of pramipexole ER that included pramipexole immediate release (IR as an active comparator. We calculated MCID as the mean change in subjects who received active treatment and rated themselves “a little better” on patient global impression of improvement (PGI-I minus the mean change in subjects who received placebo and rated themselves unchanged. Results. MCIDs in EPD (pramipexole ER, pramipexole IR for UPDRS II were −1.8 and −2.0, for UPDRS III −6.2 and −6.1, and for UPDRS II + III −8.0 and −8.1. MCIDs in APD for UPDRS II were −1.8 and −2.3, for UPDRS III −5.2 and −6.5, and for UPDRS II + III −7.1 and −8.8. MCID for “OFF” time (pramipexole ER, pramipexole IR was −1.0 and −1.3 hours. Conclusions. A range of MCIDs is emerging in the PD literature that provides the basis for power calculations and interpretation of clinical trials.

  5. Laser annealing heals radiation damage in avalanche photodiodes

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Jin Gyu [University of Waterloo, Institute for Quantum Computing, Waterloo, ON (Canada); University of Waterloo, Department of Electrical and Computer Engineering, Waterloo, ON (Canada); Anisimova, Elena; Higgins, Brendon L.; Bourgoin, Jean-Philippe [University of Waterloo, Institute for Quantum Computing, Waterloo, ON (Canada); University of Waterloo, Department of Physics and Astronomy, Waterloo, ON (Canada); Jennewein, Thomas [University of Waterloo, Institute for Quantum Computing, Waterloo, ON (Canada); University of Waterloo, Department of Physics and Astronomy, Waterloo, ON (Canada); Canadian Institute for Advanced Research, Quantum Information Science Program, Toronto, ON (Canada); Makarov, Vadim [University of Waterloo, Institute for Quantum Computing, Waterloo, ON (Canada); University of Waterloo, Department of Electrical and Computer Engineering, Waterloo, ON (Canada); University of Waterloo, Department of Physics and Astronomy, Waterloo, ON (Canada)

    2017-12-15

    Avalanche photodiodes (APDs) are a practical option for space-based quantum communications requiring single-photon detection. However, radiation damage to APDs significantly increases their dark count rates and thus reduces their useful lifetimes in orbit. We show that high-power laser annealing of irradiated APDs of three different models (Excelitas C30902SH, Excelitas SLiK, and Laser Components SAP500S2) heals the radiation damage and several APDs are restored to typical pre-radiation dark count rates. Of nine samples we test, six APDs were thermally annealed in a previous experiment as another solution to mitigate the radiation damage. Laser annealing reduces the dark count rates further in all samples with the maximum dark count rate reduction factor varying between 5.3 and 758 when operating at -80 C. This indicates that laser annealing is a more effective method than thermal annealing. The illumination power to reach these reduction factors ranges from 0.8 to 1.6 W. Other photon detection characteristics, such as photon detection efficiency, timing jitter, and afterpulsing probability, fluctuate but the overall performance of quantum communications should be largely unaffected by these variations. These results herald a promising method to extend the lifetime of a quantum satellite equipped with APDs. (orig.)

  6. SHE LOOKS LIKE US: REPRESENTATION OF IDEALIZED ETHNIC BEAUTY IN MAGAZINE’S IMAGES, LOCAL ADVERTISEMENT FOR MIGRANTS

    Directory of Open Access Journals (Sweden)

    Yumiko YAMAZAKI

    2010-07-01

    Full Text Available This study aims to examine representation of idealized beauty and self-image of Brazilian migrants (descendant of Japanese migrants to Braz il, i.e. ethnic Japanese in Hamamatsu, Japan. Hamamatsu city has the biggest population of Braz ilian migrants community in Japan, thus there's demand for ethnic goods, which are widely available at about 80 ethnic shops in city. Teen magazine is good orientation of appearance and behavior for such migrant-rooted girls, which provides concepts of "ideal beauty" and "ideal looking of self". In this study, we focus on how concept of idealized beauty appears in Brazilian teen magazines which are imported to Japan for migrants and compare with local ads, free paper, magazines, and news paper to analysis the difference between them. Previous studies show Japanese Brazilian migrants have strong identity as a descendant of Japanese migrants because of their oriental appearance and cultural roots, although their preference changes gradually toward more "Brazilian" by being rejected their Japanese identity in Japanese society. It shows also those segregated immigrants tend to over-build their cultural and ethnic identity, which appears often as more "Brazilian-like" appearance (e.g. fashion, hair style. However, our analysis indicates that their appe arance and behavior become not significant culture-of-origin-oriented, even their culture of origin-oriented appearance is also strongly influenced by host country's culture. While Brazilian magazine indicates us concept of ideal Brazilian beauty in Brazil, local advertisement for Brazilian migrants in Hamamatsu city shows us the real representation of these migrants in Japan . From this perspective, the image in local ads etc. may reflects new culture which is mixed both Japanese and Brazilian one.

  7. A case law review of the individuals with disabilities education act for children with hearing loss or auditory processing disorders.

    Science.gov (United States)

    Kreisman, Brian M; John, Andrew B

    2010-01-01

    In 1975, Congress passed the Education for All Handicapped Children Act (Public Law 94-142), and it has been revised and modified several times. At the time of this writing, this law was most recently amended by the Individuals with Disabilities Education Improvement Act (Pub. L. No. 108-446, 118 Stat. 2647, December 3, 2004), which took effect on July 1, 2005. Colloquially the law is still referred to as the Individuals with Disabilities Education Act (IDEA). Children with hearing loss or auditory processing disorder (APD) may qualify for services under IDEA. However, a review of the literature found no review of case law for such children. This article provides a comprehensive review of case law involving the IDEA and children with hearing loss or APD from the U.S. Supreme Court and U.S. courts of appeals. We conducted a systematic review of case law. A LexisNexis search for cases involving IDEA and children with hearing loss or APDs was conducted. For the purpose of the present case review, all appellate decisions (cases accepted by the U.S. courts of appeals or the U.S. Supreme Court) were included if they found that the child had hearing loss or APD, regardless of the reason for the appeal under IDEA. In the instance of multiple cases that involved the same two parties, these cases are summarized together to provide the legal context. Brief explanations of IDEA and the federal judicial process as it pertains to IDEA disputes are presented. Following these explanations, a chronological review of IDEA appellate cases concerning students with hearing loss or APD is provided. The IDEA cases reviewed focus on three main issues: placement of the child, methodology of teaching, and the provision of services. This case law review provides a helpful summary of higher court cases for educational audiologists and parents of children with hearing loss or APDs, as well as educators, individualized education program team members, school administrators, and legal

  8. 76 FR 63659 - Notice Pursuant to the National Cooperative Research and Production Act of 1993; Cooperative...

    Science.gov (United States)

    2011-10-13

    ... venture are: Ford Motor Company, Dearborn, MI; GM Global Technology Operations, Inc., Detroit, MI; Honda...; Suzuki Motor Corporation, Hamamatsu City, Japan; and Toyota, Aichi, Japan. The general area of P3's...

  9. Contribution of glucan-binding protein A to firm and stable biofilm formation by Streptococcus mutans.

    Science.gov (United States)

    Matsumi, Y; Fujita, K; Takashima, Y; Yanagida, K; Morikawa, Y; Matsumoto-Nakano, M

    2015-06-01

    Glucan-binding proteins (Gbps) of Streptococcus mutans, a major pathogen of dental caries, mediate the binding of glucans synthesized from sucrose by the action of glucosyltransferases (GTFs) encoded by gtfB, gtfC, and gtfD. Several stress proteins, including DnaK and GroEL encoded by dnaK and groEL, are related to environmental stress tolerance. The contribution of Gbp expression to biofilm formation was analyzed by focusing on the expression levels of genes encoding GTFs and stress proteins. Biofilm-forming assays were performed using GbpA-, GbpB-, and GbpC-deficient mutant strains and the parental strain MT8148. The expression levels of gtfB, gtfC, gtfD, dnaK, and groEL were evaluated by reverse transcription-quantitative polymerase chain reaction (RT-qPCR). Furthermore, the structure of biofilms formed by these Gbp-deficient mutant strains was observed using confocal laser scanning microscopy (CLSM). Biofilm-forming assay findings demonstrated that the amount formed by the GbpA-deficient mutant strain (AD1) was nearly the same as that by the parental strain, while the GbpB- and GbpC-deficient mutant strains produced lower amounts than MT8148. Furthermore, RT-qPCR assay results showed that the expressions of gtfB, dnaK, and groEL in AD1 were elevated compared with MT8148. CLSM also revealed that the structure of biofilm formed by AD1 was prominently different compared with that formed by the parental strain. These results suggest that a defect in GbpA influences the expression of genes controlling biofilm formation, indicating its importance as a protein for firm and stable biofilm formation. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Airborne measurements of CO2 column concentrations made with a pulsed IPDA lidar using a multiple-wavelength-locked laser and HgCdTe APD detector

    Science.gov (United States)

    Abshire, James B.; Ramanathan, Anand K.; Riris, Haris; Allan, Graham R.; Sun, Xiaoli; Hasselbrack, William E.; Mao, Jianping; Wu, Stewart; Chen, Jeffrey; Numata, Kenji; Kawa, Stephan R.; Yang, Mei Ying Melissa; DiGangi, Joshua

    2018-04-01

    Here we report on measurements made with an improved CO2 Sounder lidar during the ASCENDS 2014 and 2016 airborne campaigns. The changes made to the 2011 version of the lidar included incorporating a rapidly wavelength-tunable, step-locked seed laser in the transmitter, using a much more sensitive HgCdTe APD detector and using an analog digitizer with faster readout time in the receiver. We also improved the lidar's calibration approach and the XCO2 retrieval algorithm. The 2014 and 2016 flights were made over several types of topographic surfaces from 3 to 12 km aircraft altitudes in the continental US. The results are compared to the XCO2 values computed from an airborne in situ sensor during spiral-down maneuvers. The 2014 results show significantly better performance and include measurement of horizontal gradients in XCO2 made over the Midwestern US that agree with chemistry transport models. The results from the 2016 airborne lidar retrievals show precisions of ˜ 0.7 parts per million (ppm) with 1 s averaging over desert surfaces, which is an improvement of about 8 times compared to similar measurements made in 2011. Measurements in 2016 were also made over fresh snow surfaces that have lower surface reflectance at the laser wavelengths. The results from both campaigns showed that the mean values of XCO2 retrieved from the lidar consistently agreed with those based on the in situ sensor to within 1 ppm. The improved precision and accuracy demonstrated in the 2014 and 2016 flights should benefit future airborne science campaigns and advance the technique's readiness for a space-based instrument.

  11. Generalized social anxiety disorder and avoidant personality disorder: structural analysis and treatment outcome.

    Science.gov (United States)

    Huppert, Jonathan D; Strunk, Daniel R; Ledley, Deborah Roth; Davidson, Jonathan R T; Foa, Edna B

    2008-01-01

    There has been considerable controversy about whether generalized social phobia (GSP) and avoidant personality disorder (APD) are redundant diagnostic categories. In light of the ongoing controversy, more data are needed to help determine whether GSP and APD are independent constructs. Data were obtained from 335 people seeking treatment for GSP at a two site clinical trial. Indicators of GSP and APD were obtained along with assessments of demographic factors, level of functioning, and indicators of related psychopathology. Confirmatory factor analyses of indicators of GSP and APD suggested a somewhat better fit for a two-factor solution. Comparisons of GSP patients with and without APD suggested that in addition to having more severe social phobia symptoms, patients with APD were more depressed on a self-report measure and had more functional impairment, thereby suggesting potential utility of the diagnostic category of APD. Furthermore, the presence of APD predicted treatment response, in that patients with APD had more change early in treatment than those without APD. APD and GSP remain highly related constructs, and different aspects of these data support and dispute the utility of the diagnosis of APD in GSP. Possible new directions in conceptualizing APD are discussed. Published 2007 Wiley-Liss, Inc.

  12. Diagnostic accuracy of combined FP-CIT, IBZM, and MIBG scintigraphy in the differential diagnosis of degenerative parkinsonism: a multidimensional statistical approach.

    Science.gov (United States)

    Südmeyer, Martin; Antke, Christina; Zizek, Tanja; Beu, Markus; Nikolaus, Susanne; Wojtecki, Lars; Schnitzler, Alfons; Müller, Hans-Wilhelm

    2011-05-01

    In vivo molecular imaging of pre- and postsynaptic nigrostriatal neuronal degeneration and sympathetic cardiac innervation with SPECT is used to distinguish idiopathic Parkinson disease (PD) from atypical parkinsonian disorder (APD). However, the diagnostic accuracy of these imaging approaches as stand-alone procedures is often unsatisfying. The aim of this study was therefore to evaluate to which extent diagnostic accuracy can be increased by their combined use together with a multidimensional statistical algorithm. The SPECT radiotracers (123)I-(S)-2-hydroxy-3-iodo-6-methoxy-N-[1-ethyl-2-pyrrodinyl)-methyl]benzamide (IBZM), (123)I-N-ω-fluoropropyl-2β-carbomethoxy-3β-(4-iodophenyl)nortropan (FP-CIT), and meta-(123)I-iodobenzylguanidine (MIBG) were used to assess striatal postsynaptic D(2) receptor binding, striatal presynaptic dopamine transporter binding, and myocardial adrenergic innervation, respectively. Thirty-one PD and 17 APD patients were prospectively investigated. PD and APD diagnoses were established using consensus criteria and reevaluated after 37.4 ± 12.4 and 26 ± 11.6 mo in PD and APD, respectively. Test accuracy (TA) for PD-APD differentiation was computed for all logical (Boolean) combinations of imaging modalities by receiver-operating-characteristic analysis--that is, after multidimensional optimization of cutoff values. Analysis showed moderate TA for PD-APD differentiation using each molecular approach alone (IBZM, 79%; MIBG, 73%; and FP-CIT, 73%). For combined use, the highest TA resulted under the assumption that at least 2 of the 3 biologic markers had to be positive for APD using the following cutoff values: 1.46 or less for IBZM, less than 2.10 for FP-CIT, and greater than 1.43 for MIBG. This algorithm distinguished APD from PD with a sensitivity of 94%, specificity of 94% (TA, 94%), positive predictive value of 89%, and negative predictive value of 97%. Results suggest that the multidimensional combination of FP-CIT, IBZM, and MIBG

  13. Molecular Mechanisms of Antipsychotic Drug-Induced Diabetes

    Directory of Open Access Journals (Sweden)

    Jiezhong Chen

    2017-11-01

    Full Text Available Antipsychotic drugs (APDs are widely prescribed to control various mental disorders. As mental disorders are chronic diseases, these drugs are often used over a life-time. However, APDs can cause serious glucometabolic side-effects including type 2 diabetes and hyperglycaemic emergency, leading to medication non-compliance. At present, there is no effective approach to overcome these side-effects. Understanding the mechanisms for APD-induced diabetes should be helpful in prevention and treatment of these side-effects of APDs and thus improve the clinical outcomes of APDs. In this review, the potential mechanisms for APD-induced diabetes are summarized so that novel approaches can be considered to relieve APD-induced diabetes. APD-induced diabetes could be mediated by multiple mechanisms: (1 APDs can inhibit the insulin signaling pathway in the target cells such as muscle cells, hepatocytes and adipocytes to cause insulin resistance; (2 APD-induced obesity can result in high levels of free fatty acids (FFA and inflammation, which can also cause insulin resistance. (3 APDs can cause direct damage to β-cells, leading to dysfunction and apoptosis of β-cells. A recent theory considers that both β-cell damage and insulin resistance are necessary factors for the development of diabetes. In high-fat diet-induced diabetes, the compensatory ability of β-cells is gradually damaged, while APDs cause direct β-cell damage, accounting for the severe form of APD-induced diabetes. Based on these mechanisms, effective prevention of APD-induced diabetes may need an integrated approach to combat various effects of APDs on multiple pathways.

  14. Size, shape and age-related changes of the mandibular condyle during childhood

    Energy Technology Data Exchange (ETDEWEB)

    Karlo, Christoph A. [University Children' s Hospital Zurich, Department of Diagnostic Imaging, Zurich (Switzerland); University Hospital Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland); Stolzmann, Paul [University Hospital Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland); Habernig, Sandra; Kellenberger, Christian J. [University Children' s Hospital Zurich, Department of Diagnostic Imaging, Zurich (Switzerland); Mueller, Lukas [University of Zurich, Clinics for Orthodontics and Paediatric Dentistry, Zurich (Switzerland); Saurenmann, Traudel [University Children' s Hospital Zurich, Department of Rheumatology, Zurich (Switzerland)

    2010-10-15

    To determine age-related differences in the size and shape of the mandibular condyle in children to establish anatomical reference values. A total of 420 mandibular condyles in 210 children (mean age, 7 years) were retrospectively analysed by using computed tomography (CT) imaging. The greatest left-right (LRD) and anterior-posterior (APD) diameters and the anteversion angles (AA) were measured by two readers. An APD/LRD ratio was calculated. The shape of the condyles was graded into three types on sagittal images. Correlations of parameters with the children's age were assessed by using Pearson's correlation analyses. The LRD (mean, 14.1 {+-} 2.4 mm), APD (mean, 7.3 {+-} 1.0 mm) and LRD/APD ratio (mean, 1.9 {+-} 0.3) increased (r{sub LRD} = 0.70, p < 0.01; r{sub APD} = 0.56, p < 0.01; r{sub rat} = 0.28, p < 0.01) while the AA (mean, 27 {+-} 7 ) decreased significantly (r{sub antang} = -0.26, p < 0.001) with age. The condylar shape as determined on sagittal images correlated significantly with age (r = 0.69, p < 0.05). Boys had significantly higher anteversion angles (p < 0.01), greater LRDs (p < 0.05) and greater mean ratios (p < 0.05). The mandibular condyle is subject to significant age-related changes in size and shape during childhood. As the size of the condyles increases with age, the anteversion angles decrease and the shape of the condyle turns from round to oval. (orig.)

  15. Release of non-methane organic compounds during simulated landfilling of aerobically pretreated municipal solid waste.

    Science.gov (United States)

    Zhang, Yuanyuan; Yue, Dongbei; Liu, Jianguo; Lu, Peng; Wang, Ying; Liu, Jing; Nie, Yongfeng

    2012-06-30

    Characteristics of non-methane organic compounds (NMOCs) emissions during the anaerobic decomposition of untreated (APD-0) and four aerobically pretreated (APD-20, APD-39, APD-49, and APD-63) samples of municipal solid waste (MSW) were investigated in laboratory. The cumulative mass of the NMOCs of APD-20, APD-39, APD-49, and APD-63 accounted for 15%, 9%, 16%, and 15% of that of APD-0, respectively. The intensities of the NMOC emissions calculated by dividing the cumulative NMOC emissions by the quantities of organic matter removed (Q(VS)) decreased from 4.1 mg/kg Q(VS) for APD-0 to 0.8-3.4 mg/kg Q(VS) for aerobically pretreated MSW. The lipid and starch contents might have significant impact on the intensity of the NMOC emissions. Alkanes dominated the NMOCs released from the aerobically pretreated MSW, while oxygenated compounds were the chief component of the NMOCs generated from untreated MSW. Aerobic pretreatment of MSW prior to landfilling reduces the organic content of the waste and the intensity of the NMOC emissions, and increases the odor threshold, thereby reducing the environmental impact of landfills. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. 78 FR 8148 - Findings of Research Misconduct

    Science.gov (United States)

    2013-02-05

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Office of the Secretary Findings of Research Misconduct AGENCY: Office of the Secretary, HHS. ACTION: Notice. SUMMARY: Notice is hereby given that the Office of... Philosophy, August 2009; hereafter referred to as the ``Dissertation.'' Doreian, B.W., Fulop, T.G...

  17. Personality functioning in patients with avoidant personality disorder and social phobia.

    Science.gov (United States)

    Eikenaes, Ingeborg; Hummelen, Benjamin; Abrahamsen, Gun; Andrea, Helene; Wilberg, Theresa

    2013-12-01

    Avoidant personality disorder (APD) and social phobia (SP) are closely related, such that they are suggested to represent different severity levels of one social anxiety disorder. This cross-sectional study aimed to compare patients with APD to patients with SP, with particular focus on personality dysfunction. Ninety-one adult patients were examined by diagnostic interviews and self-report measures, including the Index of Self-Esteem and the Severity Indices of Personality Problems. Patients were categorized in three groups; SP without APD (n = 20), APD without SP (n = 15), and APD with SP (n = 56). Compared to patients with SP without APD, patients with APD reported more symptom disorders, psychosocial problems, criteria of personality disorders, and personality dysfunction regarding self-esteem, identity and relational problems. These results indicate that APD involves more severe and broader areas of personality dysfunction than SP, supporting the conceptualization of APD as a personality disorder as proposed for DSM-5.

  18. Antagonismo in vitro de cepas de Trichoderma spp. frente a Sarocladium oryzae (Sawada) W. Gams & D. Hawksworth

    OpenAIRE

    Martínez, Benedicto; Obret, Yalainne; Pérez, Simón; Reyes, Yusimy

    2014-01-01

    Se evaluaron 27 aislamientos de Trichoderma spp. frente a dos de Sarocladium oryzae (Sawada) W. Gams & D. Hawksworth (S. o-2 y S. o-4) utilizando la técnica de cultivo dual, comparando el crecimiento de las colonias de Sarocladium para determinar los modos de acción, en diferentes fases de la interacción. El análisis estadístico de los datos se realizó mediante la prueba T- Student. El 81,48% de los aislamientos de Trichoderma presentó competencia por el sustrato, el 25,93% antibiosis y el 11...

  19. Single-Photon-Sensitive HgCdTe Avalanche Photodiode Detector

    Science.gov (United States)

    Huntington, Andrew

    2013-01-01

    The purpose of this program was to develop single-photon-sensitive short-wavelength infrared (SWIR) and mid-wavelength infrared (MWIR) avalanche photodiode (APD) receivers based on linear-mode HgCdTe APDs, for application by NASA in light detection and ranging (lidar) sensors. Linear-mode photon-counting APDs are desired for lidar because they have a shorter pixel dead time than Geiger APDs, and can detect sequential pulse returns from multiple objects that are closely spaced in range. Linear-mode APDs can also measure photon number, which Geiger APDs cannot, adding an extra dimension to lidar scene data for multi-photon returns. High-gain APDs with low multiplication noise are required for efficient linear-mode detection of single photons because of APD gain statistics -- a low-excess-noise APD will generate detectible current pulses from single photon input at a much higher rate of occurrence than will a noisy APD operated at the same average gain. MWIR and LWIR electron-avalanche HgCdTe APDs have been shown to operate in linear mode at high average avalanche gain (M > 1000) without excess multiplication noise (F = 1), and are therefore very good candidates for linear-mode photon counting. However, detectors fashioned from these narrow-bandgap alloys require aggressive cooling to control thermal dark current. Wider-bandgap SWIR HgCdTe APDs were investigated in this program as a strategy to reduce detector cooling requirements.

  20. The Relationship between Types of Attention and Auditory Processing Skills: Reconsidering Auditory Processing Disorder Diagnosis

    Science.gov (United States)

    Stavrinos, Georgios; Iliadou, Vassiliki-Maria; Edwards, Lindsey; Sirimanna, Tony; Bamiou, Doris-Eva

    2018-01-01

    Measures of attention have been found to correlate with specific auditory processing tests in samples of children suspected of Auditory Processing Disorder (APD), but these relationships have not been adequately investigated. Despite evidence linking auditory attention and deficits/symptoms of APD, measures of attention are not routinely used in APD diagnostic protocols. The aim of the study was to examine the relationship between auditory and visual attention tests and auditory processing tests in children with APD and to assess whether a proposed diagnostic protocol for APD, including measures of attention, could provide useful information for APD management. A pilot study including 27 children, aged 7–11 years, referred for APD assessment was conducted. The validated test of everyday attention for children, with visual and auditory attention tasks, the listening in spatialized noise sentences test, the children's communication checklist questionnaire and tests from a standard APD diagnostic test battery were administered. Pearson's partial correlation analysis examining the relationship between these tests and Cochrane's Q test analysis comparing proportions of diagnosis under each proposed battery were conducted. Divided auditory and divided auditory-visual attention strongly correlated with the dichotic digits test, r = 0.68, p attention battery identified as having Attention Deficits (ADs). The proposed APD battery excluding AD cases did not have a significantly different diagnosis proportion than the standard APD battery. Finally, the newly proposed diagnostic battery, identifying an inattentive subtype of APD, identified five children who would have otherwise been considered not having ADs. The findings show that a subgroup of children with APD demonstrates underlying sustained and divided attention deficits. Attention deficits in children with APD appear to be centred around the auditory modality but further examination of types of attention in both

  1. LASER ABLATION-INDUCTIVELY COUPLED PLASMA-ATOMIC EMISSION SPECTROSCOPY STUDY AT THE 222-S LABORATORY USING HOT-CELL GLOVE BOX PROTOTYPE SYSTEM

    International Nuclear Information System (INIS)

    Lockrem, L.L.; Owens, J.W.; Seidel, C.M.

    2009-01-01

    This report describes the installation, testing and acceptance of the Waste Treatment and Immobilization Plant procured laser ablation-inductively coupled plasma-atomic emission spectroscopy (LA-ICP-AES) system for remotely analyzing high-level waste samples in a hot cell environment. The 2005-003; ATS MP 1027, Management Plan for Waste Treatment Plant Project Work Performed by Analytical Technical Services. The APD group at the 222-S laboratory demonstrated acceptable turnaround time (TAT) and provide sufficient data to assess sensitivity, accuracy, and precision of the LA-ICP-AES method

  2. CMOS integrated avalanche photodiodes and frequency-mixing optical sensor front end for portable NIR spectroscopy instruments.

    Science.gov (United States)

    Yun, Ruida; Sthalekar, Chirag; Joyner, Valencia M

    2011-01-01

    This paper presents the design and measurement results of two avalanche photodiode structures (APDs) and a novel frequency-mixing transimpedance amplifier (TIA), which are key building blocks towards a monolithically integrated optical sensor front end for near-infrared (NIR) spectroscopy applications. Two different APD structures are fabricated in an unmodified 0.18 \\im CMOS process, one with a shallow trench isolation (STI) guard ring and the other with a P-well guard ring. The APDs are characterized in linear mode. The STI bounded APD demonstrates better performance and exhibits 3.78 A/W responsivity at a wavelength of 690 nm and bias voltage of 10.55 V. The frequency-mixing TIA (FM-TIA) employs a T-feedback network incorporating gate-controlled transistors for resistance modulation, enabling the simultaneous down-conversion and amplification of the high frequency modulated photodiode (PD) current. The TIA achieves 92 dS Ω conversion gain with 0.5 V modulating voltage. The measured IIP(3) is 10.6/M. The amplifier together with the 50 Ω output buffer draws 23 mA from a1.8 V power supply.

  3. Triggered lightning return stroke luminosity to 1 km in two optical bands

    Science.gov (United States)

    Carvalho, F. L.; Uman, M. A.; Jordan, D. M.; Wilkes, R.; Kotovsky, D. A.; Hare, B.

    2017-12-01

    Measured luminosity waveforms are presented and analyzed as a function of time and channel height using two types of avalanche photodiodes (APDs) for 19 triggered-lightning return strokes during summer 2016. APD type I had an optical bandwidth from 200 nm to 1,000 nm, with peak response at 600 nm (green light), and APD type II had an optical bandwidth from 400 nm to 1,000 nm with a peak response at 800 nm (red light). Ten channel heights ranging from 0 to 1 km (in 100 m increments) were observed by both types of APDs, 20 total, and measured the luminosity in vertical channel slices of approximately 3 m. For APD type I, the return stroke luminosity waveforms generally decay faster following its singular initial peak (IP) than the waveforms recorded by APD type II. APD type II waveforms often exhibit a second maxima (SM) following the IP. Although the wave shapes recorded by each APD type diverge after the IP, the risetime of the initial luminosity wave front preceding the IP for both types of APDs agrees well. The divergence in the luminosity wave shapes following the IP indicates that APD type II is capable of recording spectral lines that are excited or enhanced after the IP more effectively than APD type I. In addition, the SM/IP ratio increases as a function of channel height, indicating that the spectral range better captured by APD type II is more predominant at the top of the channel than at the bottom. Finally, because APD type II responds better to longer wavelengths than APD type I, and because the SM occurs a few microseconds after the IP (at the channel-bottom), we conjecture that the SM following the IP is a consequence of spectral lines excited during the cooling of the channel, following the initial high-temperature/pressure stage. Our data suggests that the initial optical radiation during the return stroke is dominated by ionized atomic species (e.g. four NII lines between 450 and 600 nm, better captured by APD type I) radiated at higher

  4. The impact of the UK aviation tax on carbon dioxide emissions and visitor numbers

    NARCIS (Netherlands)

    Mayor, K.; Tol, R.S.J.

    2007-01-01

    We use a model of domestic and international tourist numbers and flows to estimate the impact of the recent and proposed changes in the Air Passenger Duty (APD) of the United Kingdom. We look at four different scenarios (abolishing the APD, keeping the 2001 APD level, the 2007 APD and the

  5. Analisis kesesuaian dan daya dukung lingkungan untuk pengembangan wisata bahari di Pulau Bawean Kabupaten Gresik Provinsi Jaya Timur

    Directory of Open Access Journals (Sweden)

    Sukandar Sukandar

    2017-09-01

    Full Text Available Bawean Island has potency as a ecotourism destination in Gresik District, Province of Jaya timur. This island is one of the popular destination for local tourist, and the visitors are increasing over the years; but there was no study on the suitability and carrying capacity of the island for marine ecotourism activities. The purpose of this study was to analysis the suitability and carrying capacity of Bawean Island for marine tourism. The Results of the analysis showed that the area of marine ocotourism in Bawean is Suitable (S1 for marine ecotourism development with a value for leisure travel 88.33%, snorkeling activity was 84.21%; and diving 81.48%. The total value carrying capacity of region was 398 persons/day. Pulau Bawean memiliki potensi sebagai daerah tujuan wisata bahari di kabupaten Gresikproins Jaya timur. Pulau ini telah menjadi tujuan wisata lokal bagi masyarakat Jaya timur dan jumlah kunjungan wisatawan semakin meningkat dari tahun ke tahun. Namu belum ada kajian mengenai kesesuaian dan daya dukung lingkungan di Pulau Bawean sebagai kawsan wisata bahari. Oleh karena itu penelitian ini bertujuan untuk mengkaji kesesuaian dan daya dukung Pulau Bawean sebagai kawasan wisata bahari. Hasil analisis menunjukkan bahwa Pulau Bawean sesuai (S1 untuk dikembangkan sebagai kawasan wisata bahari  dengan nilai untuk wisata rekreasi pantai sebesar 88,33%, wisata snorkeling sebesar 84,21% dan wisata selam sebesar 81,48%. Nilai total daya dukung kawasan sebesar 398 orang/hari.

  6. Post-processing Free Quantum Random Number Generator Based on Avalanche Photodiode Array

    International Nuclear Information System (INIS)

    Li Yang; Liao Sheng-Kai; Liang Fu-Tian; Shen Qi; Liang Hao; Peng Cheng-Zhi

    2016-01-01

    Quantum random number generators adopting single photon detection have been restricted due to the non-negligible dead time of avalanche photodiodes (APDs). We propose a new approach based on an APD array to improve the generation rate of random numbers significantly. This method compares the detectors' responses to consecutive optical pulses and generates the random sequence. We implement a demonstration experiment to show its simplicity, compactness and scalability. The generated numbers are proved to be unbiased, post-processing free, ready to use, and their randomness is verified by using the national institute of standard technology statistical test suite. The random bit generation efficiency is as high as 32.8% and the potential generation rate adopting the 32 × 32 APD array is up to tens of Gbits/s. (paper)

  7. Free-running InGaAs/InP single photon detector with feedback quenching IC

    International Nuclear Information System (INIS)

    Zheng, Fu; Wang, Feilong; Wang, Chao; Sun, Zhibin; Zhai, Guangjie

    2015-01-01

    InGaAs/InP avalanche photodiodes (APD) are usually employed as Geiger-mode single photon detector at near-infrared wavelength between 1.0 μm and 1.7 μm. In order to work in the free-running regime rather than gated regime, we demonstrate a feedback quenching integrated circuit to rapidly quench the avalanche and reset the APD. Because this IC is close to the APD, parasitic capacitance is largely reduced, thus reducing the quench-time, reset-time and also the afterpulsing probability. We investigated the free-running single photon detector's afterpulsing effect, de-trapping time, dark count rate and detection efficiency and also compared with gated regime operation. After corrected for deadtime and afterpulse, we found the free-running detector performance is comparable with gated regime

  8. Harsh-Environment Solid-State Gamma Detector for Down-hole Gas and Oil Exploration

    Energy Technology Data Exchange (ETDEWEB)

    Peter Sandvik; Stanislav Soloviev; Emad Andarawis; Ho-Young Cha; Jim Rose; Kevin Durocher; Robert Lyons; Bob Pieciuk; Jim Williams; David O' Connor

    2007-08-10

    The goal of this program was to develop a revolutionary solid-state gamma-ray detector suitable for use in down-hole gas and oil exploration. This advanced detector would employ wide-bandgap semiconductor technology to extend the gamma sensor's temperature capability up to 200 C as well as extended reliability, which significantly exceeds current designs based on photomultiplier tubes. In Phase II, project tasks were focused on optimization of the final APD design, growing and characterizing the full scintillator crystals of the selected composition, arranging the APD device packaging, developing the needed optical coupling between scintillator and APD, and characterizing the combined elements as a full detector system preparing for commercialization. What follows is a summary report from the second 18-month phase of this program.

  9. Lowering the radioactivity of the photomultiplier tubes for the XENON1T dark matter experiment

    NARCIS (Netherlands)

    Aprile, E.; et al., [Unknown; Alfonsi, M.; Colijn, A.P.; Decowski, M.P.; Tiseni, A.; Tunnell, C.

    2015-01-01

    The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410 has been developed by Hamamatsu for dark matter direct detection experiments using liquid xenon as the target material. We present the results from the joint effort between the XENON collaboration and the Hamamatsu company

  10. Neutron diffraction study of the formation kinetics of ordered antiphase domains in titanium carbohydride TiCxHy

    International Nuclear Information System (INIS)

    Khidirov, I.

    2015-01-01

    The kinetics of formation and growth of ordered antiphase domains (APDs) in titanium carbohydride TiC 0.50 H 0.21 has been investigated by neutron diffraction. A model of ordered APDs is proposed. It is established that the pronounced ordering of interstitial atoms and APDs begin at 450°C. It is shown that the period of ordered APDs (P ≈ 10–12) is independent of the exposure time at a constant temperature. It is found that the temperature of ordered APDs, T OAPD , increases nonlinearly with an increase in the carbon concentration in the range 0.50 ≤ C/Ti ≤ 0.70. The formation temperature of ordered APDs is found to correlate with the concentration dependence of the order–disorder transition temperature and be 0.60 of the order–disorder transition temperature: T APD = 0.60Τ C

  11. β1-Adrenoceptor autoantibodies affect action potential duration and delayed rectifier potassium currents in guinea pigs.

    Science.gov (United States)

    Zhao, Yuhui; Huang, Haixia; Du, Yunhui; Li, Xiao; Lv, Tingting; Zhang, Suli; Wei, Hua; Shang, Jianyu; Liu, Ping; Liu, Huirong

    2015-01-01

    β1-Adrenoceptor autoantibodies (β1-AAs) affect the action potential duration (APD) in cardiomyocytes and are related to ventricular arrhythmias. The delayed rectifier potassium current (I K) plays a crucial role in APD, but the effects of β1-AAs on I K have not been completely illuminated. This work aimed to observe the effects of β1-AAs on I K and APD and further explore the mechanisms of β1-AA-mediated ventricular arrhythmias. β1-AAs were obtained from sera of patients with coronary heart disease (CHD) and nonsustained ventricular tachycardia. With whole-cell patch clamp technique, action potentials and I K were recorded. The results illustrated 0.1 μmol/L β1-AAs shortened APD at 50 % (APD50) and 90 % (APD90) of the repolarization. However, at 0.01 μmol/L, β1-AAs had no effects on either APD90 or APD50 (P > 0.05). At 0.001 μmol/L, β1-AAs significantly prolonged APD90 and APD50. Moreover, β1-AAs (0.001, 0.01, 0.1 μmol/L) dose-dependently increased the rapidly activating delayed rectifier potassium current (I Kr), but similarly decreased the slowly activating delayed rectifier potassium current (I Ks) and increased L-type calcium currents at the different concentrations. Taken together, the IKr increase induced by high β1-AA concentrations is responsible for a significant APD reduction which would contribute to repolarization changes and trigger the malignant ventricular arrhythmias in CHD patients.

  12. Emotional dysfunction in avoidant compared to borderline personality disorder: a study of affect consciousness.

    Science.gov (United States)

    Johansen, Merete Selsbakk; Normann-Eide, Eivind; Normann-Eide, Tone; Wilberg, Theresa

    2013-12-01

    Knowledge of emotional dysfunction in patients with avoidant personality disorder (APD) is much needed. The present study examined affect consciousness (AC) in patients with APD compared to borderline personality disorder (BPD). AC, defined as capacity to perceive, reflect on, tolerate, and express emotional experiences, is assumed to be central to structure-building in personality. The study tested the hypotheses that patients with APD have lower general AC and lower AC for pleasant affects compared to BPD. Fifty-nine patients, 26 with APD and 33 with BPD were rated on several aspects of AC using the specialized AC interview. The structured interview SCID-II was applied for diagnostic evaluations. The APD group had significantly lower levels of global AC and conceptual expressivity compared to the BPD group. Among 11 specific affects the APD group had significantly lower AC for interest and contempt. Emotional dysfunction is an important feature of APD and the findings indicate that psychotherapies for APD patients should focus on emotional experiences, aiming to improve emotional awareness, tolerance, and expressivity. The notion of a general avoidance of positive emotions in APD needs further exploration, including a possible dysfunction in the evolutionary based neuro-affective Seeking system. © 2013 The Scandinavian Psychological Associations.

  13. Neutron diffraction study of the formation kinetics of ordered antiphase domains in titanium carbohydride TiC{sub x}H{sub y}

    Energy Technology Data Exchange (ETDEWEB)

    Khidirov, I., E-mail: khidirov@inp.uz [Uzbekistan Academy of Sciences, Institute of Nuclear Physics (Uzbekistan)

    2015-09-15

    The kinetics of formation and growth of ordered antiphase domains (APDs) in titanium carbohydride TiC{sub 0.50}H{sub 0.21} has been investigated by neutron diffraction. A model of ordered APDs is proposed. It is established that the pronounced ordering of interstitial atoms and APDs begin at 450°C. It is shown that the period of ordered APDs (P ≈ 10–12) is independent of the exposure time at a constant temperature. It is found that the temperature of ordered APDs, T{sub OAPD}, increases nonlinearly with an increase in the carbon concentration in the range 0.50 ≤ C/Ti ≤ 0.70. The formation temperature of ordered APDs is found to correlate with the concentration dependence of the order–disorder transition temperature and be 0.60 of the order–disorder transition temperature: T{sub APD} = 0.60Τ{sub C}.

  14. A Systematic Study to Optimize SiPM Photo-Detectors for Highest Time Resolution in PET

    CERN Document Server

    Gundacker, S.; Frisch, B.; Hillemanns, H.; Jarron, P.; Meyer, T.; Pauwels, K.; Lecoq, P.

    2012-01-01

    We report on a systematic study of time resolution made with three different commercial silicon photomultipliers (SiPMs) (Hamamatsu MPPC S10931-025P, S10931-050P, and S10931-100P) and two LSO scintillating crystals. This study aimed to determine the optimum detector conditions for highest time resolution in a prospective time-of-flight positron emission tomography (TOF-PET) system. Measurements were based on the time over threshold method in a coincidence setup using the ultrafast amplifier-discriminator NINO and a fast oscilloscope. Our tests with the three SiPMs of the same area but of different SPAD sizes and fill factors led to best results with the Hamamatsu type of 50×50×μm2 single-pixel size. For this type of SiPM and under realistic geometrical PET scanner conditions, i.e., with 2×2×10×mm3 LSO crystals, a coincidence time resolution of 220 ±4 ps FWHM could be achieved. The results are interpreted in terms of SiPM photon detection efficiency (PDE), dark noise, and photon yield.

  15. Children's Headache: Drawings in the Diagnostic Work Up.

    Science.gov (United States)

    Mazzotta, Silvia; Pavlidis, Elena; Cordori, Cecilia; Spagnoli, Carlotta; Pini, Luigi Alberto; Pisani, Francesco

    2015-08-01

    This study aims to evaluate the drawings effectiveness in childhood headache assessment. Headache is a common cause of pain in children. Although drawings have been used in childhood to recognize psychological insights and pain perception, they were rarely used for headache characterization. We collected drawings from 67 subjects with cephalalgia during a 22-month timeframe. The clinical diagnosis was made according to the 2nd edition of The International Headache Classification. Drawings were independently categorized as migraine or tension-type headache (TTH) by two child neuropsychiatrists blinded to the clinical data. Cohen kappa for interrater agreement, sensitivity, specificity, and positive predictive value (PPV) were calculated. Subjects were also divided into three age groups to assess the influence of age. Finally, a control group of 90 subjects was collected and K-means cluster analysis was performed. The drawings had a sensitivity of 85.71 and 81.48%, a specificity of 81.48 and 85.71%, and a PPV of 85.71 and 81.48%, for migraine and TTH diagnosis, respectively. Drawings by the older age group showed the highest predictability degree. Finally, by mean of cluster analysis, 59 of the 67 patients were correctly classified, whereas control subjects were similarly distributed between the two clusters. Drawings are a useful instrument for migraine and TTH differential diagnosis. Thus, we suggest their inclusion in childhood headache diagnostic assessment. Georg Thieme Verlag KG Stuttgart · New York.

  16. The Relationship between Aggression and Serum Thyroid Hormone Level in Individuals Diagnosed with Antisocial Personality Disorder.

    Science.gov (United States)

    Evrensel, Alper; Ünsalver, Barış Önen; Özşahin, Aytekin

    2016-06-01

    Aggression is one of the leading clinical characteristics of antisocial personality disorder (APD). Studies aiming to clarify and control the biological basis of aggression are ongoing. Thyroid hormones have been indicated to play a role in the development of aggression. The aim of this study was to examine the level of aggression and serum thyroid hormone in a sample of APD and to make contributions to this field with the current findings. The sample consisted of 96 subjects with a diagnosis of APD and 97 subjects as a control group. Structured Clinical Interview for DSM-IV Axis (SCID) 1 and 2 were used for the diagnosis, and the Buss-Perry Aggression Questionnaire was administered. Based on criminal patterns, the APD group was then divided into two subgroups: "criminal" and "noncriminal" APD groups. The day after the interview, after one night of fasting, blood was collected from the subjects between 7:00 a.m. and 9:00 a.m.. Thyroid function tests and other biochemical analyses related to the confounding variables were also administered. The study group and the control group were compared in terms of their aggression scores and thyroid hormone levels. The mean score of free T3 level in the criminal APD group was found to be significantly higher than that in the noncriminal APD group. APD subjects with higher free T3 levels also had higher aggression scores. In the noncriminal APD group, as serum free T3 and T4 levels increased, there was also an increment in the aggression scores. However, in the criminal APD group, there was no significant correlation between thyroid hormone levels and aggression. The findings of this study indicated that criminal and noncriminal APD groups actually show different properties.

  17. The role of the speech-language pathologist in identifying and treating children with auditory processing disorder.

    Science.gov (United States)

    Richard, Gail J

    2011-07-01

    A summary of issues regarding auditory processing disorder (APD) is presented, including some of the remaining questions and challenges raised by the articles included in the clinical forum. Evolution of APD as a diagnostic entity within audiology and speech-language pathology is reviewed. A summary of treatment efficacy results and issues is provided, as well as the continuing dilemma for speech-language pathologists (SLPs) charged with providing treatment for referred APD clients. The role of the SLP in diagnosing and treating APD remains under discussion, despite lack of efficacy data supporting auditory intervention and questions regarding the clinical relevance and validity of APD.

  18. C-RED One and C-RED2: SWIR high-performance cameras using Saphira e-APD and Snake InGaAs detectors

    Science.gov (United States)

    Gach, Jean-Luc; Feautrier, Philippe; Stadler, Eric; Clop, Fabien; Lemarchand, Stephane; Carmignani, Thomas; Wanwanscappel, Yann; Boutolleau, David

    2018-02-01

    After the development of the OCAM2 EMCCD fast visible camera dedicated to advanced adaptive optics wavefront sensing, First Light Imaging moved to the SWIR fast cameras with the development of the C-RED One and the C-RED 2 cameras. First Light Imaging's C-RED One infrared camera is capable of capturing up to 3500 full frames per second with a subelectron readout noise and very low background. C-RED One is based on the last version of the SAPHIRA detector developed by Leonardo UK. This breakthrough has been made possible thanks to the use of an e-APD infrared focal plane array which is a real disruptive technology in imagery. C-RED One is an autonomous system with an integrated cooling system and a vacuum regeneration system. It operates its sensor with a wide variety of read out techniques and processes video on-board thanks to an FPGA. We will show its performances and expose its main features. In addition to this project, First Light Imaging developed an InGaAs 640x512 fast camera with unprecedented performances in terms of noise, dark and readout speed based on the SNAKE SWIR detector from Sofradir. The camera was called C-RED 2. The C-RED 2 characteristics and performances will be described. The C-RED One project has received funding from the European Union's Horizon 2020 research and innovation program under grant agreement N° 673944. The C-RED 2 development is supported by the "Investments for the future" program and the Provence Alpes Côte d'Azur Region, in the frame of the CPER.

  19. Peritoneal dialysis technique success during the initial 90 days of therapy.

    Science.gov (United States)

    Guest, Steven; Hayes, Andrew C; Story, Kenneth; Davis, Ira D

    2012-01-01

    Comparisons of technique success by peritoneal dialysis (PD) modality have typically excluded the initial 90 days of therapy. We analyzed a database of 51,469 new PD starts from 2004 to 2008 in the United States. The analysis concentrated on the initial 90 days of therapy to determine technique success and the impact of the continuous ambulatory PD (CAPD) and automated PD (APD) modalities. Overall, 13.3% of patients stopped PD within 90 days. Of patients starting directly on APD, 14.3% stopped PD within 90 days. Of patients starting on CAPD, 12.6% stopped PD within 90 days, and 63.4% changed to APD within 90 days. Only 3.3% of the latter patients failed to reach 90 days of therapy. By comparison, technique failure occurred in 28.8% of those initiating with and remaining on CAPD. We conclude that initial training to perform CAPD, with timely transfer to APD within the first 3 months, was associated with the greatest technique success at 90 days. The reasons for that success are unclear, and further research should be directed to determining factors responsible. It is possible that patients trained initially to CAPD but converted to APD have a greater understanding of the total therapy, which improves confidence. Those converted to APD may be more appreciative of the lifestyle benefits of APD, which translates into improved compliance; alternatively, technical factors associated with APD may be responsible. Those technical factors may include improved catheter function in the recumbent position during APD or the reduced infection risk associated with just 2 connect/disconnect procedures in APD compared with 8 in CAPD.

  20. Changes in low-frequency fluctuations in patients with antisocial personality disorder revealed by resting-state functional MRI.

    Directory of Open Access Journals (Sweden)

    Huasheng Liu

    Full Text Available Antisocial Personality Disorder (APD is a personality disorder that is most commonly associated with the legal and criminal justice systems. The study of the brain in APD has important implications in legal contexts and in helping ensure social stability. However, the neural contribution to the high prevalence of APD is still unclear. In this study, we used resting-state functional magnetic resonance imaging (fMRI to investigate the underlying neural mechanisms of APD. Thirty-two healthy individuals and thirty-five patients with APD were recruited. The amplitude of low-frequency fluctuations (ALFF was analyzed for the whole brain of all subjects. Our results showed that APD patients had a significant reduction in the ALFF in the right orbitofrontal cortex, the left temporal pole, the right inferior temporal gyrus, and the left cerebellum posterior lobe compared to normal controls. We observed that the right orbitofrontal cortex had a negative correlation between ALFF values and MMPI psychopathic deviate scores. Alterations in ALFF in these specific brain regions suggest that APD patients may be associated with abnormal activities in the fronto-temporal network. We propose that our results may contribute in a clinical and forensic context to a better understanding of APD.

  1. Brief cognitive therapy for avoidant personality disorder.

    Science.gov (United States)

    Rees, Clare S; Pritchard, Rhian

    2015-03-01

    Avoidant personality disorder (APD) is associated with a high level of impairment in multiple areas of functioning. However, research on the treatment of APD is scarce, and there is an absence of empirically evaluated effective treatment approaches available. This study offers a preliminary investigation of the use of brief cognitive therapy to treat APD. Two individuals, both with a principal diagnosis of APD, but who also possessed a number of comorbidities, participated in 12 weekly sessions. A series of diagnostic symptom severity, global functioning, and self-report measures were completed at pretreatment, posttreatment and at 6-week follow-up. In addition, regular monitoring of each participant's strength of belief in 4 personally identified cognitions associated with APD was completed. Reductions in APD symptoms, associated negative affect, and increases to quality of life were observed for both participants at posttreatment and follow-up phases. Results suggest that brief cognitive therapy may be an effective treatment for APD and that further studies with larger samples are warranted. (PsycINFO Database Record (c) 2015 APA, all rights reserved).

  2. Avoidant personality disorder and its relationship to social phobia.

    Science.gov (United States)

    Reich, James

    2009-02-01

    This review summarizes past and recent findings in the empiric literature and the evolution of the concepts of avoidant personality disorder (APD) and social phobia (SP). APD is an internally consistent dimensional personality pathology that causes dysfunction that appears to be dimensional rather than a sudden jump in impairment after a certain number of criteria have been met. It has state and trait personality components. Evidence indicates that symptoms are at least partially treatable with psychological or pharmacologic interventions. APD and SP have similar symptoms and treatment response and identical genetics. We can conclude from the empiric evidence that no dividing line exists between APD and SP, with APD merely being the more severe form of the disorder. The best conceptualization is that APD is a dimensional personality pathology that in its attenuated form (SP) resembles an anxiety disorder.

  3. R&D Plan for Army Applications of AI/Robotics.

    Science.gov (United States)

    1982-05-01

    Unilever , Philips, Toshiba, and Hamamatsu. Also emerging are companies that are developing artificial intelligence and/or robotics products. U.S...ROBOTICS.. . . . ..... 83 3.1. Introduction. . . . . ...... ... ... ... . .... 83 3.2. Background .. . . . . ...... ... ... . . .... 84 3.3. A Unified...Honeywell Systems and Research Center Hughes Research Laboratories Lockheed Missiles and Space Company Martin Marietta Corporation The Rand Corporation

  4. Auditory Processing Disorders

    Science.gov (United States)

    ... many processes and problems contribute to APD in children. In adults, neurological disorders such as stroke, tumors, degenerative disease (such as multiple sclerosis), and head trauma can contribute to APD. APD in children and adults often is best managed by a ...

  5. Preamplifier development for high count-rate, large dynamic range readout of inorganic scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Keshelashvili, Irakli; Erni, Werner; Steinacher, Michael; Krusche, Bernd; Collaboration: PANDA-Collaboration

    2013-07-01

    Electromagnetic calorimeter are central component of many experiments in nuclear and particle physics. Modern ''trigger less'' detectors run with very high count-rates, require good time and energy resolution, and large dynamic range. In addition photosensors and preamplifiers must work in hostile environments (magnetic fields). Due to later constraints mainly Avalanche Photo Diodes (APD's), Vacuum Photo Triodes (VPT's), and Vacuum Photo Tetrodes (VPTT's) are used. A disadvantage is their low gain which together with other requirements is a challenge for the preamplifier design. Our group has developed special Low Noise / Low Power (LNP) preamplifier for this purpose. They will be used to equip PANDA EMC forward end-cap (dynamic range 15'000, rate 1MHz), where the PWO II crystals and preamplifier have to run in an environment cooled down to -25{sup o}C. Further application is the upgrade of the Crystal Barrel detector at the Bonn ELSA accelerator with APD readout for which special temperature comparison of the APD gain and good time resolution is necessary. Development and all test procedures after the mass production done by our group during past several years in Basel University will be reported.

  6. Superior survival of high transporters treated with automated versus continuous ambulatory peritoneal dialysis.

    Science.gov (United States)

    Johnson, David W; Hawley, Carmel M; McDonald, Stephen P; Brown, Fiona G; Rosman, Johan B; Wiggins, Kathryn J; Bannister, Kym M; Badve, Sunil V

    2010-06-01

    Automated peritoneal dialysis (APD) is widely recommended for the management of high transporters by the International Society of Peritoneal Dialysis (ISPD), although there have been no adequate studies to date comparing the outcomes of APD and continuous ambulatory peritoneal dialysis (CAPD) in this high risk group. The relative impact of APD versus CAPD on patient and technique survival rates was examined by both intention-to-treat (PD modality at Day 90) and 'as-treated' time-varying Cox proportional hazards model analyses in all patients who started PD in Australia or New Zealand between 1 April 1999 and 31 March 2004 and who had baseline peritoneal equilibration tests confirming the presence of high peritoneal transport status. During the study period, 4128 patients commenced PD. Of these, 628 patients were high transporters on PD at Day 90 (486 on APD and 142 on CAPD). Compared to high transporters treated with CAPD, APD-treated high transporters were more likely to be younger and Caucasian, and less likely to be diabetic. On multivariate intention-to-treat analysis, APD treatment was associated with superior survival [adjusted hazard ratio (HR) 0.56, 95% confidence interval (CI) 0.35-0.87] and comparable death-censored technique survival (HR 0.88, 95% CI 0.64-1.21). Superior survival of high transporters treated with APD versus CAPD was also confirmed in supplemental as-treated analysis (HR 0.72, 95% CI 0.54-0.96), matched case-control analysis (HR 0.60, 95% CI 0.36-0.96) and subgroup analysis of high transporters treated entirely with APD versus those treated entirely with CAPD (HR 0.29, 95% CI 0.14-0.60). There were no statistically significant differences in patient survival or death-censored technique survival between APD and CAPD for any other transport group, except for low transporters, who experienced a higher mortality rate on APD compared with CAPD (HR 2.19, 95% CI 1.02-4.70). APD treatment is associated with a significant survival advantage in

  7. Restitution slope is principally determined by steady-state action potential duration.

    Science.gov (United States)

    Shattock, Michael J; Park, Kyung Chan; Yang, Hsiang-Yu; Lee, Angela W C; Niederer, Steven; MacLeod, Kenneth T; Winter, James

    2017-06-01

    The steepness of the action potential duration (APD) restitution curve and local tissue refractoriness are both thought to play important roles in arrhythmogenesis. Despite this, there has been little recognition of the apparent association between steady-state APD and the slope of the restitution curve. The objective of this study was to test the hypothesis that restitution slope is determined by APD and to examine the relationship between restitution slope, refractoriness and susceptibility to VF. Experiments were conducted in isolated hearts and ventricular myocytes from adult guinea pigs and rabbits. Restitution curves were measured under control conditions and following intervention to prolong (clofilium, veratridine, bretylium, low [Ca]e, chronic transverse aortic constriction) or shorten (catecholamines, rapid pacing) ventricular APD. Despite markedly differing mechanisms of action, all interventions that prolonged the action potential led to a steepening of the restitution curve (and vice versa). Normalizing the restitution curve as a % of steady-state APD abolished the difference in restitution curves with all interventions. Effects on restitution were preserved when APD was modulated by current injection in myocytes pre-treated with the calcium chelator BAPTA-AM - to abolish the intracellular calcium transient. The non-linear relation between APD and the rate of repolarization of the action potential is shown to underpin the common influence of APD on the slope of the restitution curve. Susceptibility to VF was found to parallel changes in APD/refractoriness, rather than restitution slope. Steady-state APD is the principal determinant of the slope of the ventricular electrical restitution curve. In the absence of post-repolarization refractoriness, factors that prolong the action potential would be expected to steepen the restitution curve. However, concomitant changes in tissue refractoriness act to reduce susceptibility to sustained VF. Dependence on

  8. Heterologous Expression of Aldehyde Dehydrogenase in Lactococcus lactis for Acetaldehyde Detoxification at Low pH.

    Science.gov (United States)

    Lyu, Yunbin; LaPointe, Gisèle; Zhong, Lei; Lu, Jing; Zhang, Chong; Lu, Zhaoxin

    2018-02-01

    Aldehyde dehydrogenase (E.C. 1.2.1.x) can catalyze detoxification of acetaldehydes. A novel acetaldehyde dehydrogenase (istALDH) from the non-Saccharomyces yeast Issatchenkia terricola strain XJ-2 has been previously characterized. In this work, Lactococcus lactis with the NIsin Controlled Expression (NICE) System was applied to express the aldehyde dehydrogenase gene (istALDH) in order to catalyze oxidation of acetaldehyde at low pH. A recombinant L. lactis NZ3900 was obtained and applied for the detoxification of acetaldehyde as whole-cell biocatalysts. The activity of IstALDH in L. lactis NZ3900 (pNZ8148-istALDH) reached 36.4 U mL -1 when the recombinant cells were induced with 50 ng mL -1 nisin at 20 °C for 2 h. The IstALDH activity of recombinant L. lactis cells showed higher stability at 37 °C and pH 4.0 compared with the crude enzyme. L. lactis NZ3900 (pNZ8148-istALDH) could convert acetaldehyde at pH 2.0 while the crude enzyme could not. Moreover, the resting cells of L. lactis NZ3900 (pNZ8148-istALDH) showed a 2.5-fold higher activity and better stability in catalyzing oxidation of acetaldehyde at pH 2.0 compared with that of Escherichia coli expressing the IstALDH. Taken together, the L. lactis cells expressing recombinant IstALDH are potential whole-cell biocatalysts that can be applied in the detoxification of aldehydes.

  9. Role of the Purkinje-Muscle Junction on the Ventricular Repolarization Heterogeneity in the Healthy and Ischemic Ovine Ventricular Myocardium

    Directory of Open Access Journals (Sweden)

    Marine E. Martinez

    2018-06-01

    Full Text Available Alteration of action potential duration (APD heterogeneity contributes to arrhythmogenesis. Purkinje-muscle junctions (PMJs present differential electrophysiological properties including longer APD. The goal of this study was to determine if Purkinje-related or myocardial focal activation modulates ventricular repolarization differentially in healthy and ischemic myocardium. Simultaneous epicardial (EPI and endocardial (ENDO optical mapping was performed on sheep left ventricular (LV wedges with intact free-running Purkinje network (N = 7. Preparations were paced on either ENDO or EPI surfaces, or the free-running Purkinje fibers (PFs, mimicking normal activation. EPI and ENDO APDs were assessed for each pacing configuration, before and after (7 min of the onset of no-flow ischemia. Experiments were supported by simulations. In control conditions, maximal APD was found at endocardial PMJ sites. We observed a significant transmural APD gradient for PF pacing with PMJ APD = 347 ± 41 ms and EPI APD = 273 ± 36 ms (p < 0.001. A similar transmural gradient was observed when pacing ENDO (49 ± 31 ms; p = 0.005. However, the gradient was reduced when pacing EPI (37 ± 20 ms; p = 0.005. Global dispersion of repolarization was the most pronounced for EPI pacing. In ischemia, both ENDO and EPI APD were reduced (p = 0.005 and the transmural APD gradient (109 ± 55 ms was increased when pacing ENDO compared to control condition or when pacing EPI (p < 0.05. APD maxima remained localized at functional PMJs during ischemia. Local repolarization dispersion was significantly higher at the PMJ than at other sites. The results were consistent with simulations. We found that the activation sequence modulates repolarization heterogeneity in the ischemic sheep LV. PMJs remain active following ischemia and exert significant influence on local repolarization patterns.

  10. Short-term memory and electrical restitution in the canine transmural ventricle

    International Nuclear Information System (INIS)

    Zhang, Hong; Ueyama, Takeshi; Lin, Shien-Fong; Wang, Juan; Wu, Rui-Juan

    2011-01-01

    Cardiac short-term memory is an intrinsic property of paced myocardium that reflects the influence of pacing history. Using an optical mapping method to record membrane voltage and intracellular calcium (Ca 2+ i ), this study investigated the properties and mechanisms of short-term memory in isolated and perfused canine wedge preparations. In addition to the dynamic and S1S2 pacing protocols, a perturbed downsweep pacing protocol was used to get a complete overview of the restitution portrait. Abrupt changes in basic cycle length (BCL) were applied to investigate the accommodation process of action potential duration (APD). The results showed unobvious differences of memory among the epi-, mid- and endo-myocytes, implying an insignificant memory-induced transient heterogeneity in APD across the transmural canine hearts. With the decrease of pacing rate S1, memory gradually elevated and achieved a maximum around 400 ms, and then reduced as S1 decreased further, indicating a non-monotonic relationship between memory and the pacing rate. After suppressing the Ca 2+ i transient with ryanodine (3 µmol l −1 ), the accommodation process of APD to a new BCL significantly abbreviated (τ = 37.41 ± 4.42 stimuli before ryanodine, τ = 15.84 ± 4.74 stimuli after ryanodine, p < 0.01). Therefore, Ca 2+ i cycling was suggested to play an important role in memory during dynamic pacing

  11. Arctigenin, a potential anti-arrhythmic agent, inhibits aconitine-induced arrhythmia by regulating multi-ion channels.

    Science.gov (United States)

    Zhao, Zhenying; Yin, Yongqiang; Wu, Hong; Jiang, Min; Lou, Jianshi; Bai, Gang; Luo, Guo'an

    2013-01-01

    Arctigenin possesses biological activities, but its underlying mechanisms at the cellular and ion channel levels are not completely understood. Therefore, the present study was designed to identify the anti-arrhythmia effect of arctigenin in vivo, as well as its cellular targets and mechanisms. A rat arrhythmia model was established via continuous aconitine infusion, and the onset times of ventricular premature contraction, ventricular tachycardia and death were recorded. The Action Potential Duration (APD), sodium current (I(Na)), L-type calcium current (I(Ca, L)) and transient outward potassium current (I(to)) were measured and analysed using a patch-clamp recording technique in normal rat cardiomyocytes and myocytes of arrhythmia aconitine-induced by. Arctigenin significantly delayed the arrhythmia onset in the aconitine-induced rat model. The 50% and 90% repolarisations (APD50 and APD90) were shortened by 100 µM arctigenin; the arctigenin dose also inhibited the prolongation of APD50 and APD90 caused by 1 µM aconitine. Arctigenin inhibited I(Na) and I(Ca,L) and attenuated the aconitine-increased I(Na) and I(Ca,L) by accelerating the activation process and delaying the inactivation process. Arctigenin enhanced Ito by facilitating the activation process and delaying the inactivation process, and recoverd the decreased Ito induced by aconitine. Arctigenin has displayed anti-arrhythmia effects, both in vivo and in vitro. In the context of electrophysiology, I(Na), I(Ca, L), and I(to) may be multiple targets of arctigenin, leading to its antiarrhythmic effect. © 2013 S. Karger AG, Basel.

  12. The relationship between avoidant personality disorder and social phobia.

    Science.gov (United States)

    Hummelen, Benjamin; Wilberg, Theresa; Pedersen, Geir; Karterud, Sigmund

    2007-01-01

    The main explanatory hypothesis for the distinction between social phobia (SP) and avoidant personality disorder (APD) has been the severity continuum hypothesis, stating that APD only differs from SP in terms of severity of dysfunction and symptomatic distress, that is, social anxiety and depressive symptoms. This study aimed at a comprehensive evaluation of this hypothesis in a large sample (n = 2192) of thoroughly assessed patients, most of whom had a diagnosis of personality disorder. Social phobia was stronger associated with APD than with other personality disorders, and APD was stronger associated with SP than with other symptom disorders. Social phobia-pure patients had a higher level of global functioning and lower levels of general symptom distress and interpersonal problems than APD-pure patients. The 2 groups were similar on domains that pertain to social anxiety and introversion, but APD was associated with a broader array of symptoms and interpersonal problems and was substantially lower on the personality domain of conscientiousness. Avoidant personality disorder was stronger associated with eating disorders, and SP was stronger associated with panic disorder. The APD diagnosis seems to capture a broader constellation of symptoms and personality features pointing toward more severe personality dysfunction. Our findings suggest that the severity continuum hypothesis lacks specificity and exploratory power to account for both similarities and differences between SP and APD.

  13. Comparison of peritonitis rates and patient survival in automated and continuous ambulatory peritoneal dialysis: a 10-year single center experience.

    Science.gov (United States)

    El-Reshaid, Wael; Al-Disawy, Hanan; Nassef, Hossameldeen; Alhelaly, Usama

    2016-09-01

    Peritonitis is a common complication in patients undergoing continuous ambulatory peritoneal dialysis (CAPD) and automated peritoneal dialysis (APD). In this retrospective study, peritonitis rates and patient survival of 180 patients on CAPD and 128 patients on APD were compared in the period from January 2005 to December 2014 at Al-Nafisi Center in Kuwait. All patients had prophylactic topical mupirocin at catheter exit site. Patients on CAPD had twin bag system with Y transfer set. The peritonitis rates were 1 in 29 months in CAPD and 1 in 38 months in APD (p peritonitis free patients over 10-year period in CAPD and APD were 49 and 60%, respectively (p peritonitis was 10.25 ± 3.1 months in CAPD compared to 16.1 ± 4 months in APD (p peritonitis was 13.1 ± 1 and 14 ± 1.4 months respectively (p = 0.3) whereas in peritonitis free patients it was 15 ± 1.4 months in CAPD and 23 ± 3.1 months in APD (p = 0.025). APD had lower incidence rate of peritonitis than CAPD. Patient survival was better in APD than CAPD in peritonitis free patients but was similar in patients who had peritonitis.

  14. Antisocial Personality as a Neurodevelopmental Disorder.

    Science.gov (United States)

    Raine, Adrian

    2018-05-07

    Although antisocial personality disorder (APD) is one of the most researched personality disorders, it is still surprisingly resistant to treatment. This lack of clinical progress may be partly due to the failure to view APD as a neurodevelopmental disorder and to consider early interventions. After first defining what constitutes a neurodevelopmental disorder, this review evaluates the extent to which APD meets neurodevelopmental criteria, covering structural and functional brain imaging, neurocognition, genetics and epigenetics, neurochemistry, and early health risk factors. Prevention and intervention strategies for APD are then outlined, focusing on addressing early biological and health systems, followed by forensic and clinical implications. It is argued both that APD meets criteria for consideration as a neurodevelopmental disorder and that consideration should be given both to the possibility that early onset conduct disorder is neurodevelopmental in nature, and also to the inclusion of psychopathy as a specifier in future Diagnostic and Statistical Manual revisions of APD.

  15. Speed and accuracy of facial expression classification in avoidant personality disorder: a preliminary study.

    Science.gov (United States)

    Rosenthal, M Zachary; Kim, Kwanguk; Herr, Nathaniel R; Smoski, Moria J; Cheavens, Jennifer S; Lynch, Thomas R; Kosson, David S

    2011-10-01

    The aim of this preliminary study was to examine whether individuals with avoidant personality disorder (APD) could be characterized by deficits in the classification of dynamically presented facial emotional expressions. Using a community sample of adults with APD (n = 17) and non-APD controls (n = 16), speed and accuracy of facial emotional expression recognition was investigated in a task that morphs facial expressions from neutral to prototypical expressions (Multi-Morph Facial Affect Recognition Task; Blair, Colledge, Murray, & Mitchell, 2001). Results indicated that individuals with APD were significantly more likely than controls to make errors when classifying fully expressed fear. However, no differences were found between groups in the speed to correctly classify facial emotional expressions. The findings are some of the first to investigate facial emotional processing in a sample of individuals with APD and point to an underlying deficit in processing social cues that may be involved in the maintenance of APD.

  16. Towards on-chip integration of brain imaging photodetectors using standard CMOS process.

    Science.gov (United States)

    Kamrani, Ehsan; Lesage, Frederic; Sawan, Mohamad

    2013-01-01

    The main effects of on-chip integration on the performance and efficiency of silicon avalanche photodiode (SiAPD) and photodetector front-end is addressed in this paper based on the simulation and fabrication experiments. Two different silicon APDs are fabricated separately and also integrated with a transimpedance amplifier (TIA) front-end using standard CMOS technology. SiAPDs are designed in p+/n-well structure with guard rings realized in different shapes. The TIA front-end has been designed using distributed-gain concept combined with resistive-feedback and common-gate topology to reach low-noise and high gain-bandwidth product (GBW) characteristics. The integrated SiAPDs show higher signal-to-noise ratio (SNR), sensitivity and detection efficiency comparing to the separate SiAPDs. The integration does not show a significant effect on the gain and preserves the low power consumption. Using APDs with p-well guard-ring is preferred due to the higher observed efficiency after integration.

  17. Deleting the accessory subunit KChIP2 results in loss of I(to,f) and increased I(K,slow) that maintains normal action potential configuration

    DEFF Research Database (Denmark)

    Thomsen, Morten B; Sosunov, Eugene A; Anyukhovsky, Evgeny P

    2008-01-01

    BACKGROUND: Four voltage-gated potassium currents, I(to,f) (K(V)4.2), I(to,s) (K(V)1.4), I(K,slow) (K(V)1.5+K(V)2.1), and I(SS) (TASK1), govern murine ventricular repolarization. Although the accessory subunit KChIP2 influences I(to,f) expression, in preliminary experiments we found that action...... potential duration (APD) is maintained in KChIP2 knockout mice. OBJECTIVE: We tested the role of KChIP2 in regulating APD and studied the underlying ionic currents. METHODS: We used microelectrode techniques, whole-cell patch clamp studies, and real-time polymerase chain reaction amplification...... to characterize ventricular repolarization and its determinants in wild-type and KChIP2(-/-) mice. RESULTS: Despite comparable baseline action potentials, APD was more markedly prolonged by 4-aminopyridine (4-AP) in KChIP2(-/-) preparations. Peak K(+) current densities were similar in wild-type and KChIP2...

  18. Proof-of-concept and feasibility demonstrations for an avalanche photodiode/photoelastic modulator-based imaging polarimeter

    Data.gov (United States)

    National Aeronautics and Space Administration — Building on the successful heritage of JPL’s Multiangle SpectroPolarimetric Imager (MSPI), we propose infusing HgCdTe avalanche photodiode (APD) array technology...

  19. Teor e qualidade de substâncias húmicas de planossolo sob diferentes sistemas de cultivo

    OpenAIRE

    Rosa,Carla Machado da; Castilhos,Rosa Maria Vargas; Dick,Deborah Pinheiro; Pauletto,Eloy Antonio; Gomes,Algenor da Silva

    2008-01-01

    Este trabalho teve por objetivo avaliar e comparar os teores e as características químicas das substâncias húmicas (SHs) de um Planossolo háplico submetido a diferentes sistemas de cultivos de arroz. Amostras de solo foram coletadas em um experimento de longa duração (19 anos) nas profundidades de 0-0,025, 0,025-0,05, 0,05-0,20m e no topo do horizonte B. Os tratamentos avaliados foram: APC-Sistema de cultivo contínuo de arroz (preparo convencional) e controle de invasoras com herbicida, APD-S...

  20. Electrophysiologic effects of the IK1 inhibitor PA-6 are modulated by extracellular potassium in isolated guinea pig hearts

    DEFF Research Database (Denmark)

    Hoeker, Gregory S; Skarsfeldt, Mark A; Jespersen, Thomas

    2017-01-01

    in Langendorff-perfused guinea pig hearts. PA-6 (200 nm) or vehicle was perfused into ex-vivo guinea pig hearts for 60 min. Hearts were optically mapped with di-4-ANEPPS to quantify CV and APD at 90% repolarization (APD90). Ventricular APD90was significantly prolonged in hearts treated with PA-6 (115 ± 2...... APD90to a lesser degree, but profoundly increased CV Thus, in intact guinea pig hearts, the electrophysiologic effects of the IK1inhibitor, PA-6, are [K+]o-dependent....

  1. Scintillation detector composed by new type of avalanche photodiode and CsI(Tl) crystal

    International Nuclear Information System (INIS)

    He Jingtang; Chen Duanbao; Li Zuhao; Mao Yufang; Dong Xiaoli

    1996-01-01

    Using S5345 type of avalanche photodiode produced by Hamamatsu for the CsI(Tl) crystal readout, the spectrum of γ ray were measured. Energy resolution of 6.8% for 1.27 MeV γ ray from 22 Na source was obtained. The relation between energy resolution and coupling area, dimension of crystal, shaping time and bias were measured

  2. Disease Evolution and Response to Rapamycin in Activated Phosphoinositide 3-Kinase δ Syndrome: The European Society for Immunodeficiencies-Activated Phosphoinositide 3-Kinase δ Syndrome Registry

    Directory of Open Access Journals (Sweden)

    Maria Elena Maccari

    2018-03-01

    Full Text Available Activated phosphoinositide 3-kinase (PI3K δ Syndrome (APDS, caused by autosomal dominant mutations in PIK3CD (APDS1 or PIK3R1 (APDS2, is a heterogeneous primary immunodeficiency. While initial cohort-descriptions summarized the spectrum of clinical and immunological manifestations, questions about long-term disease evolution and response to therapy remain. The prospective European Society for Immunodeficiencies (ESID-APDS registry aims to characterize the disease course, identify outcome predictors, and evaluate treatment responses. So far, 77 patients have been recruited (51 APDS1, 26 APDS2. Analysis of disease evolution in the first 68 patients pinpoints the early occurrence of recurrent respiratory infections followed by chronic lymphoproliferation, gastrointestinal manifestations, and cytopenias. Although most manifestations occur by age 15, adult-onset and asymptomatic courses were documented. Bronchiectasis was observed in 24/40 APDS1 patients who received a CT-scan compared with 4/15 APDS2 patients. By age 20, half of the patients had received at least one immunosuppressant, but 2–3 lines of immunosuppressive therapy were not unusual before age 10. Response to rapamycin was rated by physician visual analog scale as good in 10, moderate in 9, and poor in 7. Lymphoproliferation showed the best response (8 complete, 11 partial, 6 no remission, while bowel inflammation (3 complete, 3 partial, 9 no remission and cytopenia (3 complete, 2 partial, 9 no remission responded less well. Hence, non-lymphoproliferative manifestations should be a key target for novel therapies. This report from the ESID-APDS registry provides comprehensive baseline documentation for a growing cohort that will be followed prospectively to establish prognostic factors and identify patients for treatment studies.

  3. About this Publishing System

    African Journals Online (AJOL)

    This journal uses Open Journal Systems 2.4.3.0, which is open source journal management and publishing software developed, supported, and freely distributed by the Public Knowledge Project under the GNU General Public License. OJS Editorial and Publishing Process. ISSN: 1821-8148. AJOL African Journals Online.

  4. Space Deficits in Parkinson’s Disease Patients: Quantitative or Qualitative Differences from Normal Controls?

    Directory of Open Access Journals (Sweden)

    D. Natsopoulos

    1993-01-01

    Full Text Available Twenty-seven patients with idiopathic Parkinson's disease (PD and the same number of normal controls (NCs were studied on a test battery including five conceptual categories of spatial ability. The two groups of subjects were matched for age, sex, years of education, socioeconomic status and non-verbal (Raven Standard Progressive Matrices intelligence. A multivariate analysis of variance (MANOVA showed that the PD patients performed less efficiently on almost all the tasks. A logistic regression analysis (LRA classified 81.48% of the subjects into the PD group and 92.59% into NC group, indicating that left-right and back-front Euclidean orientation, three dimensional mental rotation and visuospatial immediate recognition memory of mirror image patterns discriminate well between the two groups. Application of a structural model (confirmatory factor analysis demonstrated that both PD patients and the NC group stemmed from a homogeneous population, suggesting that the differences found between the two groups are of a quantitative rather than of a qualitative nature.

  5. Avoidant personality disorder is a separable schizophrenia-spectrum personality disorder even when controlling for the presence of paranoid and schizotypal personality disorders The UCLA family study.

    Science.gov (United States)

    Fogelson, D L; Nuechterlein, K H; Asarnow, R A; Payne, D L; Subotnik, K L; Jacobson, K C; Neale, M C; Kendler, K S

    2007-03-01

    It is unresolved whether avoidant personality disorder (APD) is an independent schizophrenia (Sz)-spectrum personality disorder (PD). Some studies find APD and social anxiety symptoms (Sxs) to be separable dimensions of psychopathology in relatives (Rels) of schizophrenics while other studies find avoidant Sxs to be correlated with schizotypal and paranoid Sxs. Rates of APD among first-degree Rels of Sz probands, attention-deficit/hyperactivity disorder (ADHD) probands, and community control (CC) probands were examined. Further analyses examined rates when controlling for the presence of schizotypal (SPD) and paranoid (PPD) personality disorders, differences in APD Sxs between relative groups, and whether APD in Rels of Szs reflects a near miss for another Sz-spectrum PD. Three hundred sixty-two first-degree Rels of Sz probands, 201 relatives of ADHD probands, and 245 Rels of CC probands were interviewed for the presence of DSM-III-R Axis I and II disorders. Diagnoses, integrating family history, interview information, and medical records, were determined. APD occurred more frequently in Rels of Sz probands compared to CC probands (pavoids social or occupational activities..." and "exaggerates the potential difficulties..." 65% of the Rels of Sz probands who had diagnoses of APD were more than one criterion short of a DSM-III-R diagnosis of either SPD or PPD. This indicates that APD is a separate Sz-spectrum disorder, and not merely a sub-clinical form of SPD or PPD.

  6. ASTEROID POLARIMETRIC DATABASE V6.0

    Data.gov (United States)

    National Aeronautics and Space Administration — The Asteroid Polarimetric Database (APD) is a collection of asteroid polarimetry results compiled by D.F. Lupishko and S.V. Vasiliev of Karazin Kharkiv National...

  7. Global Security | La sécurité globale

    Directory of Open Access Journals (Sweden)

    2012-05-01

    Full Text Available Peacekeeping Operations Expenditure, Humanitarian Assistance and ODA, 1990–2010 (in billion USD constant, 2009Dépenses pour les opérations de maintien de la paix, aide humanitaire et APD, 1990-2010 (en milliards USD constants de 2009Sources: OECD, OECD.Stat Extracts, http://stats.oecd.org/Index.aspx; UN, United Nations Peacekeeping, http://www.un.org/en/peacekeeping; Renner, M., Peacekeeping Expenditures in Current vs. Real Terms 1947–2005, http://www.globalpolicy.org; UN documents A/63/5 (...

  8. Ventricular action potential adaptation to regular exercise: role of β-adrenergic and KATP channel function.

    Science.gov (United States)

    Wang, Xinrui; Fitts, Robert H

    2017-08-01

    Regular exercise training is known to affect the action potential duration (APD) and improve heart function, but involvement of β-adrenergic receptor (β-AR) subtypes and/or the ATP-sensitive K + (K ATP ) channel is unknown. To address this, female and male Sprague-Dawley rats were randomly assigned to voluntary wheel-running or control groups; they were anesthetized after 6-8 wk of training, and myocytes were isolated. Exercise training significantly increased APD of apex and base myocytes at 1 Hz and decreased APD at 10 Hz. Ca 2+ transient durations reflected the changes in APD, while Ca 2+ transient amplitudes were unaffected by wheel running. The nonselective β-AR agonist isoproterenol shortened the myocyte APD, an effect reduced by wheel running. The isoproterenol-induced shortening of APD was largely reversed by the selective β 1 -AR blocker atenolol, but not the β 2 -AR blocker ICI 118,551, providing evidence that wheel running reduced the sensitivity of the β 1 -AR. At 10 Hz, the K ATP channel inhibitor glibenclamide prolonged the myocyte APD more in exercise-trained than control rats, implicating a role for this channel in the exercise-induced APD shortening at 10 Hz. A novel finding of this work was the dual importance of altered β 1 -AR responsiveness and K ATP channel function in the training-induced regulation of APD. Of physiological importance to the beating heart, the reduced response to adrenergic agonists would enhance cardiac contractility at resting rates, where sympathetic drive is low, by prolonging APD and Ca 2+ influx; during exercise, an increase in K ATP channel activity would shorten APD and, thus, protect the heart against Ca 2+ overload or inadequate filling. NEW & NOTEWORTHY Our data demonstrated that regular exercise prolonged the action potential and Ca 2+ transient durations in myocytes isolated from apex and base regions at 1-Hz and shortened both at 10-Hz stimulation. Novel findings were that wheel running shifted the

  9. The use of active personal dosemeters as a personal monitoring device: Comparison with TL dosimetry

    International Nuclear Information System (INIS)

    Boziari, A.; Koukorava, C.; Carinou, E.; Hourdakis, C. J.; Kamenopoulou, V.

    2011-01-01

    The use of active personal dosemeters (APDs) not only as a warning device but also, in some cases, as an official and hence stand-alone dosemeter is rapidly increasing. A comparison in terms of dose, energy and angle dependence, among different types of APD and a routinely used whole-body thermoluminescence dosemeter (TLD) has been performed. Significant differences were found between the TLD readings and mainly some not commonly used APDs. The importance of choosing the best adapted APD according to the radiation field characteristics is pointed out. (authors)

  10. Spectral dependence of the main parameters of ITE silicon avalanche photodiodes

    Science.gov (United States)

    Wegrzecka, Iwona; Grynglas, Maria; Wegrzecki, Maciej

    2001-08-01

    New applications for avalanche photodiodes (APDs) as in systems using visible radiation, have prompted the need for the evaluation of detection properties of ITE APDs in the 400 divided by 700 nm spectral range. The paper presents the method and result of studies on the spectral dependence of the gain, dark and noise currents, sensitivity and excess noise factor of ITE APDs. The studies have shown that ITE APDs optimized for the near IR radiation can be effectively applied in the detection of radiation above the 500 nm wavelength.

  11. Diagnosis and subtypes of adolescent antisocial personality disorder.

    Science.gov (United States)

    Jones, Meredith; Westen, Drew

    2010-04-01

    The present study examined the application of the Antisocial Personality Disorder (APD) diagnosis to adolescents and investigated the possibility of subtypes of APD adolescents. As part of a broader study of adolescent personality in clinically-referred patients, experienced clinicians provided personality data on a randomly selected patient in their care using the SWAP-II-A personality pathology instrument. Three hundred thirteen adolescents met adult DSM-IV diagnostic criteria for APD. To characterize adolescents with the disorder, we aggregated the data to identify the items most descriptive and distinctive of APD adolescents relative to other teenagers in the sample (N = 950). Q-factor analysis identified five personality subtypes: psychopathic-like, socially withdrawn, impulsive-histrionic, emotionally dysregulated, and attentionally dysregulated. The five subtypes differed in predictable ways on a set of external criteria related to global adaptive functioning, childhood family environment, and family history of psychiatric illness. Both the APD diagnosis and the empirically derived APD subtypes provided incremental validity over and above the DSM-IV disruptive behavior disorders in predicting global adaptive functioning, number of arrests, early-onset severe externalizing pathology, and quality of peer relationships. Although preliminary, these results provide support for the use of both APD and personality-based subtyping systems in adolescents.

  12. Predictions of silicon avalanche photodiode detector performance in water vapor differential absorption lidar

    Science.gov (United States)

    Kenimer, R. L.

    1988-01-01

    Performance analyses are presented which establish that over most of the range of signals expected for a down-looking differential absorption lidar (DIAL) operated at 16 km the silicon avalanche photodiode (APD) is the preferred detector for DIAL measurements of atmospheric water vapor in the 730 nm spectral region. The higher quantum efficiency of the APD's, (0.8-0.9) compared to a photomultiplier's (0.04-0.18) more than offsets the higher noise of an APD receiver. In addition to offering lower noise and hence lower random error the APD's excellent linearity and impulse recovery minimize DIAL systematic errors attributable to the detector. Estimates of the effect of detector system parameters on overall random and systematic DIAL errors are presented, and performance predictions are supported by laboratory characterization data for an APD receiver system.

  13. CCD developed for scientific application by Hamamatsu

    CERN Document Server

    Miyaguchi, K; Dezaki, J; Yamamoto, K

    1999-01-01

    We have developed CCDs for scientific applications that feature a low readout noise of less than 5 e-rms and low dark current of 10-25 pA/cm sup 2 at room temperature. CCDs with these characteristics will prove extremely useful in applications such as spectroscopic measurement and dental radiography. In addition, a large-area CCD of 2kx4k pixels and 15 mu m square pixel size has recently been completed for optical use in astronomical observations. Applications to X-ray astronomy require the most challenging device performance in terms of deep depletion, high CTE, and focal plane size, among others. An abuttable X-ray CCD, having 1024x1024 pixels and 24 mu m square pixel size, is to be installed in an international space station (ISS). We are now striving to achieve the lowest usable cooling temperature by means of a built-in TEC with limited power consumption. Details on the development status are described in this report. We would also like to present our future plans for a large active area and deep depleti...

  14. Assessment of children with suspected auditory processing disorder: a factor analysis study.

    Science.gov (United States)

    Ahmmed, Ansar U; Ahmmed, Afsara A; Bath, Julie R; Ferguson, Melanie A; Plack, Christopher J; Moore, David R

    2014-01-01

    To identify the factors that may underlie the deficits in children with listening difficulties, despite normal pure-tone audiograms. These children may have auditory processing disorder (APD), but there is no universally agreed consensus as to what constitutes APD. The authors therefore refer to these children as children with suspected APD (susAPD) and aim to clarify the role of attention, cognition, memory, sensorimotor processing speed, speech, and nonspeech auditory processing in susAPD. It was expected that a factor analysis would show how nonauditory and supramodal factors relate to auditory behavioral measures in such children with susAPD. This would facilitate greater understanding of the nature of listening difficulties, thus further helping with characterizing APD and designing multimodal test batteries to diagnose APD. Factor analysis of outcomes from 110 children (68 male, 42 female; aged 6 to 11 years) with susAPD on a widely used clinical test battery (SCAN-C) and a research test battery (MRC Institute of Hearing Research Multi-center Auditory Processing "IMAP"), that have age-based normative data. The IMAP included backward masking, simultaneous masking, frequency discrimination, nonverbal intelligence, working memory, reading, alerting attention and motor reaction times to auditory and visual stimuli. SCAN-C included monaural low-redundancy speech (auditory closure and speech in noise) and dichotic listening tests (competing words and competing sentences) that assess divided auditory attention and hence executive attention. Three factors were extracted: "general auditory processing," "working memory and executive attention," and "processing speed and alerting attention." Frequency discrimination, backward masking, simultaneous masking, and monaural low-redundancy speech tests represented the "general auditory processing" factor. Dichotic listening and the IMAP cognitive tests (apart from nonverbal intelligence) were represented in the "working

  15. Alarm personal dosemeter

    International Nuclear Information System (INIS)

    Nunomiya, Tomoya; Yamauchi, Hideshi; Shibata, Tetsuo

    2007-01-01

    Fuji Electric advanced the development of the conventional alarm personal dosemeter (APD) by adopting JIS Z 4312 (2002), which reflects IEC61526 (1998), and by improving the radiation performance characteristics, electromagnetic performance characteristics and mechanical performance characteristics of the APD (acquiring a CE marking). This new dosemeter will target overseas market in the future. The APD is a suitable dosemeter for detecting and monitoring radiation exposure to personnel working in the controlled areas of nuclear facilities, such as nuclear power stations. The APD product line includes 'gamma ray', 'gamma ray + beta ray' and 'gamma ray + neutron' models. (author)

  16. Clinical characteristics of self-mutilating behavior in Turkish male subjects with antisocial personality disorder: relationship to psychopathy.

    Science.gov (United States)

    Alpay Ates, M; Algul, Ayhan; Semiz, Umit B; Gecici, Omer; Basoglu, Cengiz; Ebrinc, Servet; Cetin, Mesut

    2011-05-01

    The aims of this study were to determine the characteristics of self-mutilation (SM) and examine the relationship between SM and psychopathy in male subjects with antisocial personality disorder (APD). APD diagnosis was established by the Structured Clinical Interview for DSM-III-R Axis II Disorders. Subjects (N = 116) were assessed using the Psychopathy Checklist-Revised and a semi-structured self-mutilation questionnaire form. In males with APD, the percentages of psychopathy and SM were 48.3% (N =56) and 96.6% (N = 112), respectively. There were positive correlations between severity of psychopathy and severity, number, and frequency of SM. Considerably high rates of SM and psychopathy were found in Turkish males with APD. The features of SM were associated with comorbidity of psychopathy. These results showed the importance of exploring the self-injurious behavior and psychopathy when diagnosed with APD.

  17. White matter abnormalities in young males with antisocial personality disorder Evidence from voxel-based morphometry-diffeomorphic anatomical registration using exponentiated lie algebra analysis

    Institute of Scientific and Technical Information of China (English)

    Daxing Wu; Ying Zhao; Jian Liao; Huifang Yin; Wei Wang

    2011-01-01

    Voxel-based morphometry-diffeomorphic anatomical registration using exponentiated lie algebra analysis was used to investigate the structural characteristics of white matter in young males with antisocial personality disorder (APD) and healthy controls without APD. The results revealed that APD subjects, relative to healthy subjects, exhibited increased white matter volume in the bilateral prefrontal lobe, right insula, precentral gyrus, bilateral superior temporal gyrus, right postcentral gyrus, right inferior parietal lobule, right precuneus, right middle occipital lobe, right parahippocampal gyrus and bilateral cingulate, and decreased volume in the middle temporal cortex and right cerebellum. The white matter volume in the medial frontal gyrus was significantly correlated with antisocial type scores on the Personality Diagnostic Questionnaire in APD subjects. These experimental findings indicate that white matter abnormalities in several brain areas may contribute to antisocial behaviors in APD subjects.

  18. Evaluation of phase sensitive detection method and Si avalanche photodiode for radiation thermometry

    International Nuclear Information System (INIS)

    Hobbs, M J; Tan, C H; Willmott, J R

    2013-01-01

    We report the evaluation of Si avalanche photodiodes (APDs) for use in radiation thermometry as an alternative to Si photodiodes. We compared their performance when operated under phase sensitive detection (PSD), where the signal is modulated, and direct detection (DD) methods. A Si APD was compared with a Si photodiode with reference black body temperatures of 275 to 600°C, in terms of the mean output voltage and signal-to-noise ratio (SNR), measured at different APD gain values. We found that using both PSD and DD methods, the high internal gain of the Si APD achieved a lower minimum detection temperature in order to satisfy a specific minimum output voltage of the detector-preamplifier combination employed. The use of PSD over DD for the Si APD allowed for improved performance of the thermometer, with a lower minimum measurable temperature, as well as improvement in the SNR. For instance we found that at 350°C, the Si APD biased at 150 V using PSD can provide ∼ 88 times enhancement in the system SNR over that of a Si photodiode using DD. A corresponding temperature error of ±0.05°C was achieved using the APD with PSD compared to an error of ±2.75°C measured using the Si photodiode with DD.

  19. Approaches to single photon detection

    International Nuclear Information System (INIS)

    Thew, R.T.; Curtz, N.; Eraerds, P.; Walenta, N.; Gautier, J.-D.; Koller, E.; Zhang, J.; Gisin, N.; Zbinden, H.

    2009-01-01

    We present recent results on our development of single photon detectors, including: gated and free-running InGaAs/InP avalanche photodiodes (APDs); hybrid detection systems based on sum-frequency generation (SFG) and Si APDs-SFG-Si APDs; and SSPDs (superconducting single photon detectors), for telecom wavelengths; as well as SiPM (Silicon photomultiplier) detectors operating in the visible regime.

  20. Performance of the latest MPPCs with reduced dark counts and improved photon detection efficiency

    International Nuclear Information System (INIS)

    Tsujikawa, T.; Funamoto, H.; Kataoka, J.; Fujita, T.; Nishiyama, T.; Kurei, Y.; Sato, K.; Yamamura, K.; Nakamura, S.

    2014-01-01

    We have tested the performance of two types of the latest Multi-Pixel Photon Counters (MPPCs; measuring 3×3 mm 2 in size) developed by Hamamatsu Photonics K.K. The new S12572-050C is a successor to the S10362-33-050C (i.e., conventional 3×3-mm 2 pixel MPPC of 50 μm pitch), comprises 3600 Geiger mode avalanche photodiodes (APDs), and also features high gain (up to 1.25×10 6 ), a low dark count (up to 10 6 cps), and improved photon detection efficiency (PDE) by up to 30%. The S12572-015C is a new type of fine-pitch (15 μm) MPPC featuring a wide dynamic range and fast timing response. This paper first presents the detailed performance of these latest MPPCs as photon counting devices. It then describes our fabrication of a prototype detector consisting of a MPPC optically coupled with a Ce:GAGG scintillator. We obtained average FWHM energy resolutions of 7.3% (15 μm) and 6.7% (new-50 μm), as compared to 6.9% (old-50 μm) for 662-keV gamma rays from the 137 Cs source, as measured at 20 °C. Moreover, the number of fired pixels for 662-keV gamma rays increased by 30% for the new-50 μm (as compared to the old-50 μm). We confirmed that the low energy threshold improved from 10 keV to 4 keV, when using the latest MPPC device (new-50 μm). We also confirmed that the timing resolution of the new MPPC is 50 ps or even better, as compared to 89 ps of the old MPPC. The results thus confirm that these new types of MPPCs are promising for various applications as scintillation detectors. - Highlights: • We tested the performance of the latest MPPC. • We confirmed that the new MPPC is superior to the old MPPC. • We plan to apply the new MPPC for a next-generation PET and a handy Compton camera

  1. Performance of the latest MPPCs with reduced dark counts and improved photon detection efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Tsujikawa, T., E-mail: takayuki-t.w@asagi.waseda.jp [Research Institute for Science and Engineering, Waseda University, 3-4-1, Ohkubo, Shinjuku, Tokyo (Japan); Funamoto, H.; Kataoka, J.; Fujita, T.; Nishiyama, T.; Kurei, Y. [Research Institute for Science and Engineering, Waseda University, 3-4-1, Ohkubo, Shinjuku, Tokyo (Japan); Sato, K.; Yamamura, K.; Nakamura, S. [Solid State Division, Hamamatsu Photonics K. K., 1126-1, Ichino-cho, Hamamatsu, Shizuoka (Japan)

    2014-11-21

    We have tested the performance of two types of the latest Multi-Pixel Photon Counters (MPPCs; measuring 3×3 mm{sup 2} in size) developed by Hamamatsu Photonics K.K. The new S12572-050C is a successor to the S10362-33-050C (i.e., conventional 3×3-mm{sup 2} pixel MPPC of 50 μm pitch), comprises 3600 Geiger mode avalanche photodiodes (APDs), and also features high gain (up to 1.25×10{sup 6}), a low dark count (up to 10{sup 6} cps), and improved photon detection efficiency (PDE) by up to 30%. The S12572-015C is a new type of fine-pitch (15 μm) MPPC featuring a wide dynamic range and fast timing response. This paper first presents the detailed performance of these latest MPPCs as photon counting devices. It then describes our fabrication of a prototype detector consisting of a MPPC optically coupled with a Ce:GAGG scintillator. We obtained average FWHM energy resolutions of 7.3% (15 μm) and 6.7% (new-50 μm), as compared to 6.9% (old-50 μm) for 662-keV gamma rays from the {sup 137}Cs source, as measured at 20 °C. Moreover, the number of fired pixels for 662-keV gamma rays increased by 30% for the new-50 μm (as compared to the old-50 μm). We confirmed that the low energy threshold improved from 10 keV to 4 keV, when using the latest MPPC device (new-50 μm). We also confirmed that the timing resolution of the new MPPC is 50 ps or even better, as compared to 89 ps of the old MPPC. The results thus confirm that these new types of MPPCs are promising for various applications as scintillation detectors. - Highlights: • We tested the performance of the latest MPPC. • We confirmed that the new MPPC is superior to the old MPPC. • We plan to apply the new MPPC for a next-generation PET and a handy Compton camera.

  2. [Short-term sentence memory in children with auditory processing disorders].

    Science.gov (United States)

    Kiese-Himmel, C

    2010-05-01

    To compare sentence repetition performance of different groups of children with Auditory Processing Disorders (APD) and to examine the relationship between age or respectively nonverbal intelligence and sentence recall. Nonverbal intelligence was measured with the COLOURED MATRICES, in addition the children completed a standardized test of SENTENCE REPETITION (SR) which requires to repeat spoken sentences (subtest of the HEIDELBERGER SPRACHENTWICKLUNGSTEST). Three clinical groups (n=49 with monosymptomatic APD; n=29 with APD+developmental language impairment; n=14 with APD+developmental dyslexia); two control groups (n=13 typically developing peers without any clinical developmental disorder; n=10 children with slight reduced nonverbal intelligence). The analysis showed a significant group effect (p=0.0007). The best performance was achieved by the normal controls (T-score 52.9; SD 6.4; Min 42; Max 59) followed by children with monosymptomatic APD (43.2; SD 9.2), children with the co-morbid-conditions APD+developmental dyslexia (43.1; SD 10.3), and APD+developmental language impairment (39.4; SD 9.4). The clinical control group presented the lowest performance, on average (38.6; SD 9.6). Accordingly, language-impaired children and children with slight reductions in intelligence could poorly use their grammatical knowledge for SR. A statistically significant improvement in SR was verified with the increase of age with the exception of children belonging to the small group with lowered intelligence. This group comprised the oldest children. Nonverbal intelligence correlated positively with SR only in children with below average-range intelligence (0.62; p=0.054). The absence of APD, SLI as well as the presence of normal intelligence facilitated the use of phonological information for SR.

  3. Inhibitory neuron and hippocampal circuit dysfunction in an aged mouse model of Alzheimer's disease.

    Directory of Open Access Journals (Sweden)

    Anupam Hazra

    Full Text Available In Alzheimer's disease (AD, a decline in explicit memory is one of the earliest signs of disease and is associated with hippocampal dysfunction. Amyloid protein exerts a disruptive impact on neuronal function, but the specific effects on hippocampal network activity are not well known. In this study, fast voltage-sensitive dye imaging and extracellular and whole-cell electrophysiology were used on entorhinal cortical-hippocampal slice preparations to characterize hippocampal network activity in 12-16 month old female APPswe/PSEN1DeltaE9 (APdE9 mice mice. Aged APdE9 mice exhibited profound disruptions in dentate gyrus circuit activation. High frequency stimulation of the perforant pathway in the dentate gyrus (DG area of APdE9 mouse tissue evoked abnormally large field potential responses corresponding to the wider neural activation maps. Whole-cell patch clamp recordings of the identified inhibitory interneurons in the molecular layer of DG revealed that they fail to reliably fire action potentials. Taken together, abnormal DG excitability and an inhibitory neuron failure to generate action potentials are suggested to be important contributors to the underlying cellular mechanisms of early-stage Alzheimer's disease pathophysiology.

  4. Ultra-small platinum and gold nanoparticles by arc plasma deposition

    International Nuclear Information System (INIS)

    Kim, Sang Hoon; Jeong, Young Eun; Ha, Heonphil; Byun, Ji Young; Kim, Young Dok

    2014-01-01

    Highlights: • Ultra-small (<2 nm) and bigger platinum and gold nanoparticles were produced by arc plasma deposition (APD). • Size and coverage of deposited nanoparticles were easily controlled with APD parameters. • Crystalline structures of deposited nanoparticles emerged only when the particle size was bigger than ∼2 nm. - Abstract: Ultra-small (<2 nm) nanoparticles of platinum and gold were produced by arc plasma deposition (APD) in a systematic way and the deposition behavior was studied. Nanoparticles were deposited on two dimensional amorphous carbon and amorphous titania thin films and characterized by transmission electron microscopy (TEM). Deposition behavior of nanoparticles by APD was studied with discharge voltage (V), discharge condenser capacitance (C), and the number of plasma pulse shots (n) as controllable parameters. The average size of intrinsic nanoparticles generated by APD process was as small as 0.9 nm and deposited nanoparticles began to have crystal structures from the particle size of about 2 nm. V was the most sensitive parameter to control the size and coverage of generated nanoparticles compared to C and n. Size of APD deposited nanoparticles was also influenced by the nature of evaporating materials and substrates

  5. Configurable Electronics with Low Noise and 14-bit Dynamic Range for Photodiode-based Photon Detectors

    CERN Document Server

    Müller, H; Yin, Z; Zhou, D; Cao, X; Li, Q; Liu, Y; Zou, F; Skaali, B; Awes, T C

    2006-01-01

    We describe the principles and measured performance characteristics of custom configurable 32-channel shaper/digitizer Front End Electronics (FEE) cards with 14-bit dynamic range for use with gain-adjustable photon detectors. The electronics has been designed for the PHOS calorimeter of ALICE with avalanche photodiode (APD) readout operated at -25 C ambient temperature and a signal shaping time of $1 {\\mu}s$. The electronics has also been adopted by the EMCal detector of ALICE with the same APD readout, but operated at an ambient temperature of +20 C and with a shaping time of 100ns. The CR-RC2 signal shapers on the FEE cards are implemented in discrete logic on a 10-layer board with two shaper sections for each input channel. The two shaper sections with gain ratio of 16:1 are digitized by 10-bit ADCs and provide an effective dynamic range of 14 bits. Gain adjustment for each individual APD is available through 32 bias voltage control registers of 10-bit range. The fixed gains and shaping times of the pole-z...

  6. Author Details

    African Journals Online (AJOL)

    Neema, Clementia Murembe. Vol 4, No 2 (2016) - Articles Microcredit in Uganda: Fundamental Reform or Just another Neoliberal Policy? Abstract PDF. ISSN: 1821-8148. AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's · More about AJOL · AJOL's Partners · Terms ...

  7. Author Details

    African Journals Online (AJOL)

    Brux, Jacqueline Murray. Vol 4, No 2 (2016) - Articles Microcredit in Uganda: Fundamental Reform or Just another Neoliberal Policy? Abstract PDF. ISSN: 1821-8148. AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's · More about AJOL · AJOL's Partners · Terms and ...

  8. [Effects of dauricine on action potentials and slow inward currents of guinea pig ventricular papillary muscles].

    Science.gov (United States)

    Li, S N; Zhang, K Y

    1992-11-01

    Effects of dauricine (Dau) on the action potentials (AP), the slow action potentials (SAP), and the slow inward currents (Isi) of guinea pig ventricular papillary muscles were observed by means of intracellular microelectrode and single sucrose gap voltage clamp technique. In the early stage, Dau shortened action potential duration 100 (APD100) and effective refractory period (ERP) (ERP/APD ERP, and APD20, significantly decreased action potential amplitude (APA), maximum velocity (Vmax), and overshot (OS) (ERP/APD > 1; P SAP induced by isoprenaline (P < 0.01), and remarkably inhibited Isi (P < 0.01). The results suggested that Dau exerted an inhibitory effect on Na+, Ca2+, and K+ channels.

  9. Discrimination Voltage and Overdrive Bias Dependent Performance Evaluation of Passively Quenched SiC Single-Photon-Counting Avalanche Photodiodes

    International Nuclear Information System (INIS)

    Liu Fei; Yang Sen; Zhou Dong; Lu Hai; Zhang Rong; Zheng You-Dou

    2015-01-01

    In many critical civil and emerging military applications, low-level UV detection, sometimes at single photon level, is highly desired. In this work, a mesa-type 4H-SiC UV avalanche photodiode (APD) is designed and fabricated, which exhibits low leakage current and high avalanche gain. When studied by using a passive quenching circuit, the APD exhibits self-quenching characteristics due to its high differential resistance in the avalanche region. The single photon detection efficiency and dark count rate of the APD are evaluated as functions of discrimination voltage and over-drive voltage. The optimized operation conditions of the single photon counting APD are discussed. (paper)

  10. Amygdala Reactivity and Negative Emotionality: Divergent Correlates of Antisocial Personality and Psychopathy Traits in a Community Sample

    OpenAIRE

    Hyde, Luke W.; Byrd, Amy L.; Votruba-Drzal, Elizabeth; Hariri, Ahmad R.; Manuck, Stephen B.

    2014-01-01

    Previous studies have emphasized that antisocial personality disorder (APD) and psychopathy overlap highly but differ critically in several features, notably negative emotionality (NEM) and possibly amygdala reactivity to social signals of threat and distress. Here we examined whether dimensions of psychopathy and APD correlate differentially with NEM and amygdala reactivity to emotional faces. Testing these relationships among healthy individuals, dimensions of psychopathy and APD were gener...

  11. Is decreased diameter of renal pelvis in prone position an indicator of successful pyeloplasty?

    International Nuclear Information System (INIS)

    Sharma, Gyanendra; Sharma, Anshu; Leung, Vivian Yee-Fong; Chu, Winnie Chiu-Wing

    2016-01-01

    To evaluate patients who had undergone pyeloplasty for pelviureteric junction obstruction, by measuring the anteroposterior diameter (APD) of the renal pelvis in supine and prone positions, and determine whether a decrease in APD in prone position can exclude obstruction in dilated renal system. From January 2012 to December 2013, patients who had undergone pyeloplasty were evaluated by ultrasound in two centers. The difference of APD of the renal pelvis in supine and prone positions was obtained. Correlation was made with the pre- and post-pyeloplasty renal function by radionuclide renogram. There were 42 patients (31 males, 11 females; age range 5 months to 18 years). Residual hydronephrosis was detected in 41 patients of whom 35 patients (85%) showed decrease in APD by >10% in prone position. These patients and the one without hydronephrosis showed either no deterioration or improvement in renal function. Six patients (15%) showed either no change or increase in APD in prone position. Three patients (7.5%) were confirmed to have decrease in renal function indicating obstruction. Three patients (7.5%) showed no deterioration of renal function, but sluggish drainage on radionuclide renogram. Demonstration of decreased APD of renal pelvis in prone position by ultrasound is useful to differentiate obstructed from non-obstructed dilated renal system, and it correctly identified 85% candidates with successful pyeloplasty. In patients with no decrease or increase in APD at prone position, further follow-up is recommended to rule out obstruction

  12. Not Accepted by the Family: "Being Difficult" or "Being Different"?

    Science.gov (United States)

    Komter, Aafke; Voorpostel, Marieke; Pels, Trees

    2011-01-01

    Using data from the Netherlands Kinship Panel Study (NKPS) and combining a quantitative approach and a qualitative approach (N = 8,148 and n = 43, respectively), this study investigates the mechanisms associated with a lack of acceptance by one's family. From the total NKPS sample, 12.1% did not feel (entirely) accepted by their family. The…

  13. Author Details

    African Journals Online (AJOL)

    Kayandabila, Y. Vol 1, No 2 (2013) - Articles Fiscal Policy and Debt Dynamic: Evidence from Tanzania Abstract PDF. ISSN: 1821-8148. AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's · More about AJOL · AJOL's Partners · Terms and Conditions of Use · Contact AJOL ...

  14. Author Details

    African Journals Online (AJOL)

    Miller, Paige. Vol 4, No 2 (2016) - Articles Microcredit in Uganda: Fundamental Reform or Just another Neoliberal Policy? Abstract PDF. ISSN: 1821-8148. AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's · More about AJOL · AJOL's Partners · Terms and Conditions of ...

  15. Author Details

    African Journals Online (AJOL)

    Ngowi, HP. Vol 3, No 1 (2015) - Articles The 2008 Economic Crisis: Implications and Responses in the Banking Sector Abstract PDF. ISSN: 1821-8148. AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's · More about AJOL · AJOL's Partners · Terms and Conditions of ...

  16. Depressive disorders and anti-parkinson drug treatment

    DEFF Research Database (Denmark)

    Brandt-Christensen, M; Lopez, A G; Nilsson, F M

    2007-01-01

    OBJECTIVE: To estimate the rate of treatment with anti-parkinson drugs (APD) among patients with depression. METHOD: In a nationwide case register linkage study, all persons with a main diagnosis of depression during 5 years were identified. A control group of persons with diagnoses of osteoarthr...... that prescription of APD reflects the presence of Parkinson's disease, results support a positive statistical association between depressive disorders and Parkinson's disease.......OBJECTIVE: To estimate the rate of treatment with anti-parkinson drugs (APD) among patients with depression. METHOD: In a nationwide case register linkage study, all persons with a main diagnosis of depression during 5 years were identified. A control group of persons with diagnoses...... of osteoarthritis was included. The subsequent risk of getting treatment with APD was estimated for the two groups. Statistical analyses involved Poisson's regression and competing risk models. RESULTS: A total of 14 991 persons were included. The rate of getting APD was 2.57 (95% CI: 1.46-4.52) times higher...

  17. Investigation of Avalanche Photodiodes and Multipixel Photon Counters as Light Detectors for Cosmic Rays

    Science.gov (United States)

    Vasquez, Jaime; Saavedra, Arthur; Ramos, Roxana; Tavares, Pablo; Wade, Marcus; Fan, Sewan; Haag, Brooke

    2013-04-01

    Through the Research Scholars Institute, students of Hartnell Community College experimented with the application of avalanche photodiodes (APDs) as cosmic ray detectors during the summer of 2012. An APD detector was coupled with a 10 meter long wavelength shifting fiber (WSF) wrapped around a cylindrical plastic scintillator to maximize signal detection. A photomultiplier tube (PMT) was used in conjunction to detect the same scintillation light caused by incoming cosmic rays. Two APD detectors were evaluated to confirm the viability of the setup. In addition, a similar setup was recently utilized to implement multi-pixel photon counters (MPPCs) as readout detectors. Under this configuration, a high gain preamplifier was used to amplify the signals for both the MPPC and APD detectors. We report on our results characterizing the MPPC and discuss its overall performance. Compared to the APD, our findings suggest that the MPPC detector has greater sensitivity in detecting weak light signals, and can be used in place of the PMT for certain counting applications.

  18. Beat-to-beat variability of cardiac action potential duration: underlying mechanism and clinical implications.

    Science.gov (United States)

    Nánási, Péter P; Magyar, János; Varró, András; Ördög, Balázs

    2017-10-01

    Beat-to-beat variability of cardiac action potential duration (short-term variability, SV) is a common feature of various cardiac preparations, including the human heart. Although it is believed to be one of the best arrhythmia predictors, the underlying mechanisms are not fully understood at present. The magnitude of SV is basically determined by the intensity of cell-to-cell coupling in multicellular preparations and by the duration of the action potential (APD). To compensate for the APD-dependent nature of SV, the concept of relative SV (RSV) has been introduced by normalizing the changes of SV to the concomitant changes in APD. RSV is reduced by I Ca , I Kr , and I Ks while increased by I Na , suggesting that ion currents involved in the negative feedback regulation of APD tend to keep RSV at a low level. RSV is also influenced by intracellular calcium concentration and tissue redox potential. The clinical implications of APD variability is discussed in detail.

  19. Menstrual hygiene management among Bangladeshi adolescent schoolgirls and risk factors affecting school absence: results from a cross-sectional survey.

    Science.gov (United States)

    Alam, Mahbub-Ul; Luby, Stephen P; Halder, Amal K; Islam, Khairul; Opel, Aftab; Shoab, Abul K; Ghosh, Probir K; Rahman, Mahbubur; Mahon, Therese; Unicomb, Leanne

    2017-07-09

    Many adolescent girls in low-income and middle-income countries lack appropriate facilities and support in school to manage menstruation. Little research has been conducted on how menstruation affects school absence. This study examines the association of menstrual hygiene management knowledge, facilities and practice with absence from school during menstruation among Bangladeshi schoolgirls. We conducted a nationally representative, cross-sectional study in Bangladeshi schools from March to June 2013 among girls 11 to 17 years old who reached menarche. We sampled 700 schools from 50 urban and 50 rural clusters using a probability proportional to size technique. We interviewed 2332 schoolgirls and conducted spot checks in each school for menstrual hygiene facilities. To assess factors associated with reported school absence, we estimated adjusted prevalence difference (APD) for controlling confounders' effect using generalised estimating equations to account for school-level clustering. Among schoolgirls who reached menarche, 41% (931) reported missing school, an average of 2.8 missed days per menstrual cycle. Students who felt uncomfortable at school during menstruation (99% vs 32%; APD=58%; CI 54 to 63) and who believed menstrual problems interfere with school performance (64% vs 30%; APD=27; CI 20 to 33) were more likely to miss school during menstruation than those who did not. School absence during menstruation was less common among girls attending schools with unlocked toilet for girls (35% vs 43%; APD=-5.4; CI -10 to -1.6). School absence was more common among girls who were forbidden from any activities during menstruation (41% vs 33%; APD=9.1; CI 3.3 to 14). Risk factors for school absence included girl's attitude, misconceptions about menstruation, insufficient and inadequate facilities at school, and family restriction. Enabling girls to manage menstruation at school by providing knowledge and management methods prior to menarche, privacy and a

  20. Masking of the contribution of V protein to sendai virus pathogenesis in an infection model with a highly virulent field isolate

    International Nuclear Information System (INIS)

    Sakaguchi, Takemasa; Kiyotani, Katsuhiro; Watanabe, Hitoshi; Huang Cheng; Fukuhara, Noriko; Fujii, Yutaka; Shimazu, Yukie; Sugahara, Fumihiro; Nagai, Yoshiyuki; Yoshida, Tetsuya

    2003-01-01

    Sendai virus V protein is not essential for virus replication in cultured cells but is essential for efficient virus replication and pathogenesis in mice, indicating that the V protein has a luxury function to facilitate virus propagation in mice. This was discovered in the Z strain, an egg-adapted avirulent laboratory strain. In the present study, we reexamined the function of Sendai virus V protein by generating a V-knockout Sendai virus derived from the Hamamatsu strain, a virulent field isolate, which is an appropriate model for studying the natural course of Sendai virus infection in mice. We unexpectedly found that the V-knockout virus propagated efficiently in mice and was as virulent as the wild-type virus. Switching of the functionally important V unique region demonstrated that this region of the Hamamatsu strain was also functional in a Z strain background. It thus appears that the V protein is nonsense in a field isolate of Sendai virus. However, the V protein was required for virus growth and pathogenesis of the Hamamatsu strain in mice when the virulence of the virus was attenuated by introducing mutations that had been found in an egg-adapted, avirulent virus. The V protein therefore seems to be potentially functional in the highly virulent Hamamatsu strain and to be prominent if virus replication is restricted

  1. Effect of areal power density and relative humidity on corrosion resistant container performance

    International Nuclear Information System (INIS)

    Gansemer, J.D.

    1994-10-01

    The impact of the rewetting process on the performance of waste containers at the Yucca Mountain repository is analyzed. This paper explores the impact of the temperature-humidity relationships on pitting corrosion failure of stainless steel containers for different areal power densities (APDs)in the repository. It compares the likely performance of containers in a repository with a low APD, 55 Kw/acre, and a high APD, 110 kW/acre

  2. Classification of typical and atypical antipsychotic drugs on the basis of dopamine D-1, D-2 and serotonin2 pKi values.

    Science.gov (United States)

    Meltzer, H Y; Matsubara, S; Lee, J C

    1989-10-01

    The pKi values of 13 reference typical and 7 reference atypical antipsychotic drugs (APDs) for rat striatal dopamine D-1 and D-2 receptor binding sites and cortical serotonin (5-HT2) receptor binding sites were determined. The atypical antipsychotics had significantly lower pKi values for the D-2 but not 5-HT2 binding sites. There was a trend for a lower pKi value for the D-1 binding site for the atypical APD. The 5-HT2 and D-1 pKi values were correlated for the typical APD whereas the 5-HT2 and D-2 pKi values were correlated for the atypical APD. A stepwise discriminant function analysis to determine the independent contribution of each pKi value for a given binding site to the classification as a typical or atypical APD entered the D-2 pKi value first, followed by the 5-HT2 pKi value. The D-1 pKi value was not entered. A discriminant function analysis correctly classified 19 of 20 of these compounds plus 14 of 17 additional test compounds as typical or atypical APD for an overall correct classification rate of 89.2%. The major contributors to the discriminant function were the D-2 and 5-HT2 pKi values. A cluster analysis based only on the 5-HT2/D2 ratio grouped 15 of 17 atypical + one typical APD in one cluster and 19 of 20 typical + two atypical APDs in a second cluster, for an overall correct classification rate of 91.9%. When the stepwise discriminant function was repeated for all 37 compounds, only the D-2 and 5-HT2 pKi values were entered into the discriminant function.(ABSTRACT TRUNCATED AT 250 WORDS)

  3. Atrial Heterogeneity Generates Re-entrant Substrate during Atrial Fibrillation and Anti-arrhythmic Drug Action: Mechanistic Insights from Canine Atrial Models

    Science.gov (United States)

    Varela, Marta; Hancox, Jules C.; Aslanidi, Oleg V.

    2016-01-01

    Anti-arrhythmic drug therapy is a frontline treatment for atrial fibrillation (AF), but its success rates are highly variable. This is due to incomplete understanding of the mechanisms of action of specific drugs on the atrial substrate at different stages of AF progression. We aimed to elucidate the role of cellular, tissue and organ level atrial heterogeneities in the generation of a re-entrant substrate during AF progression, and their modulation by the acute action of selected anti-arrhythmic drugs. To explore the complex cell-to-organ mechanisms, a detailed biophysical models of the entire 3D canine atria was developed. The model incorporated atrial geometry and fibre orientation from high-resolution micro-computed tomography, region-specific atrial cell electrophysiology and the effects of progressive AF-induced remodelling. The actions of multi-channel class III anti-arrhythmic agents vernakalant and amiodarone were introduced in the model by inhibiting appropriate ionic channel currents according to experimentally reported concentration-response relationships. AF was initiated by applied ectopic pacing in the pulmonary veins, which led to the generation of localized sustained re-entrant waves (rotors), followed by progressive wave breakdown and rotor multiplication in both atria. The simulated AF scenarios were in agreement with observations in canine models and patients. The 3D atrial simulations revealed that a re-entrant substrate was typically provided by tissue regions of high heterogeneity of action potential duration (APD). Amiodarone increased atrial APD and reduced APD heterogeneity and was more effective in terminating AF than vernakalant, which increased both APD and APD dispersion. In summary, the initiation and sustenance of rotors in AF is linked to atrial APD heterogeneity and APD reduction due to progressive remodelling. Our results suggest that anti-arrhythmic strategies that increase atrial APD without increasing its dispersion are

  4. Dynamic Action Potential Restitution Contributes to Mechanical Restitution in Right Ventricular Myocytes From Pulmonary Hypertensive Rats.

    Science.gov (United States)

    Hardy, Matthew E L; Pervolaraki, Eleftheria; Bernus, Olivier; White, Ed

    2018-01-01

    We investigated the steepened dynamic action potential duration (APD) restitution of rats with pulmonary artery hypertension (PAH) and right ventricular (RV) failure and tested whether the observed APD restitution properties were responsible for negative mechanical restitution in these myocytes. PAH and RV failure were provoked in male Wistar rats by a single injection of monocrotaline (MCT) and compared with saline-injected animals (CON). Action potentials were recorded from isolated RV myocytes at stimulation frequencies between 1 and 9 Hz. Action potential waveforms recorded at 1 Hz were used as voltage clamp profiles (action potential clamp) at stimulation frequencies between 1 and 7 Hz to evoke rate-dependent currents. Voltage clamp profiles mimicking typical CON and MCT APD restitution were applied and cell shortening simultaneously monitored. Compared with CON myocytes, MCT myocytes were hypertrophied; had less polarized diastolic membrane potentials; had action potentials that were triggered by decreased positive current density and shortened by decreased negative current density; APD was longer and APD restitution steeper. APD90 restitution was unchanged by exposure to the late Na + -channel blocker (5 μM) ranolazine or the intracellular Ca 2+ buffer BAPTA. Under AP clamp, stimulation frequency-dependent inward currents were smaller in MCT myocytes and were abolished by BAPTA. In MCT myocytes, increasing stimulation frequency decreased contraction amplitude when depolarization duration was shortened, to mimic APD restitution, but not when depolarization duration was maintained. We present new evidence that the membrane potential of PAH myocytes is less stable than normal myocytes, being more easily perturbed by external currents. These observations can explain increased susceptibility to arrhythmias. We also present novel evidence that negative APD restitution is at least in part responsible for the negative mechanical restitution in PAH myocytes. Thus

  5. Response of CMS avalanche photo-diodes to low energy neutrons

    Science.gov (United States)

    Brown, R. M.; Deiters, K.; Ingram, Q.; Renker, D.

    2012-12-01

    The response of the Avalanche Photo-diodes (APDs) installed in the CMS detector at the LHC to neutrons from 241AmBe and 252Cf sources is reported. Signals in size equivalent to those of up to 106 photo-electrons with the nominal APD gain are observed. Measurements with an APD with the protective epoxy coating removed and with the source placed behind the APD show that there is an important response due to recoil protons from neutron interactions with the hydrogen in the epoxy, in addition to signals from neutron interactions with the silicon of the diode. The effective gain of these signals is much smaller than the diode's nominal gain.

  6. Auditory processing disorders: an update for speech-language pathologists.

    Science.gov (United States)

    DeBonis, David A; Moncrieff, Deborah

    2008-02-01

    Unanswered questions regarding the nature of auditory processing disorders (APDs), how best to identify at-risk students, how best to diagnose and differentiate APDs from other disorders, and concerns about the lack of valid treatments have resulted in ongoing confusion and skepticism about the diagnostic validity of this label. This poses challenges for speech-language pathologists (SLPs) who are working with school-age children and whose scope of practice includes APD screening and intervention. The purpose of this article is to address some of the questions commonly asked by SLPs regarding APDs in school-age children. This article is also intended to serve as a resource for SLPs to be used in deciding what role they will or will not play with respect to APDs in school-age children. The methodology used in this article included a computerized database review of the latest published information on APD, with an emphasis on the work of established researchers and expert panels, including articles from the American Speech-Language-Hearing Association and the American Academy of Audiology. The article concludes with the authors' recommendations for continued research and their views on the appropriate role of the SLP in performing careful screening, making referrals, and supporting intervention.

  7. Sub-millisecond electron density profile measurement at the JET tokamak with the fast lithium beam emission spectroscopy system

    Science.gov (United States)

    Réfy, D. I.; Brix, M.; Gomes, R.; Tál, B.; Zoletnik, S.; Dunai, D.; Kocsis, G.; Kálvin, S.; Szabolics, T.; JET Contributors

    2018-04-01

    Diagnostic alkali atom (e.g., lithium) beams are routinely used to diagnose magnetically confined plasmas, namely, to measure the plasma electron density profile in the edge and the scrape off layer region. A light splitting optics system was installed into the observation system of the lithium beam emission spectroscopy diagnostic at the Joint European Torus (JET) tokamak, which allows simultaneous measurement of the beam light emission with a spectrometer and a fast avalanche photodiode (APD) camera. The spectrometer measurement allows density profile reconstruction with ˜10 ms time resolution, absolute position calculation from the Doppler shift, spectral background subtraction as well as relative intensity calibration of the channels for each discharge. The APD system is capable of measuring light intensities on the microsecond time scale. However ˜100 μs integration is needed to have an acceptable signal to noise ratio due to moderate light levels. Fast modulation of the beam up to 30 kHz is implemented which allows background subtraction on the 100 μs time scale. The measurement covers the 0.9 background subtraction, the relative calibration, and the comprehensive error calculation, runs a Bayesian density reconstruction code, and loads results to the JET database. The paper demonstrates the capability of the APD system by analyzing fast phenomena like pellet injection and edge localized modes.

  8. Amygdala reactivity and negative emotionality: divergent correlates of antisocial personality and psychopathy traits in a community sample.

    Science.gov (United States)

    Hyde, Luke W; Byrd, Amy L; Votruba-Drzal, Elizabeth; Hariri, Ahmad R; Manuck, Stephen B

    2014-02-01

    Previous studies have emphasized that antisocial personality disorder (APD) and psychopathy overlap highly but differ critically in several features, notably negative emotionality (NEM) and possibly amygdala reactivity to social signals of threat and distress. Here we examined whether dimensions of psychopathy and APD correlate differentially with NEM and amygdala reactivity to emotional faces. Testing these relationships among healthy individuals, dimensions of psychopathy and APD were generated by the profile matching technique of Lynam and Widiger (2001), using facet scales of the NEO Personality Inventory-Revised, and amygdala reactivity was measured using a well-established emotional faces task, in a community sample of 103 men and women. Higher psychopathy scores were associated with lower NEM and lower amygdala reactivity, whereas higher APD scores were related to greater NEM and greater amygdala reactivity, but only after overlapping variance in APD and psychopathy was adjusted for in the statistical model. Amygdala reactivity did not mediate the relationship of APD and psychopathy scores to NEM. Supplemental analyses also compared other measures of factors within psychopathy in predicting NEM and amygdala reactivity and found that Factor 2 psychopathy was positively related to NEM and amygdala reactivity across measures of psychopathy. The overall findings replicate seminal observations on NEM in psychopathy by Hicks and Patrick (2006) and extend this work to neuroimaging in a normative population. They also suggest that one critical way in which APD and psychopathy dimensions may differ in their etiology is through their opposing levels of NEM and amygdala reactivity to threat. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  9. Impaired Na⁺-dependent regulation of acetylcholine-activated inward-rectifier K⁺ current modulates action potential rate dependence in patients with chronic atrial fibrillation.

    Science.gov (United States)

    Voigt, Niels; Heijman, Jordi; Trausch, Anne; Mintert-Jancke, Elisa; Pott, Lutz; Ravens, Ursula; Dobrev, Dobromir

    2013-08-01

    Shortened action-potential duration (APD) and blunted APD rate adaptation are hallmarks of chronic atrial fibrillation (cAF). Basal and muscarinic (M)-receptor-activated inward-rectifier K(+) currents (IK1 and IK,ACh, respectively) contribute to regulation of human atrial APD and are subject to cAF-dependent remodeling. Intracellular Na(+) ([Na(+)]i) enhances IK,ACh in experimental models but the effect of [Na(+)]i-dependent regulation of inward-rectifier K(+) currents on APD in human atrial myocytes is currently unknown. Here, we report a [Na(+)]i-dependent inhibition of outward IK1 in atrial myocytes from sinus rhythm (SR) or cAF patients. In contrast, IK,ACh activated by carbachol, a non-selective M-receptor agonist, increased with elevation of [Na(+)]i in SR. This [Na(+)]i-dependent IK,ACh regulation was absent in cAF. Including [Na(+)]i dependence of IK1 and IK,ACh in a recent computational model of the human atrial myocyte revealed that [Na(+)]i accumulation at fast rates inhibits IK1 and blunts physiological APD rate dependence in both groups. [Na(+)]i-dependent IK,ACh augmentation at fast rates increased APD rate dependence in SR, but not in cAF. These results identify impaired Na(+)-sensitivity of IK,ACh as one potential mechanism contributing to the blunted APD rate dependence in patients with cAF. This article is part of a Special Issue entitled "Na(+) Regulation in Cardiac Myocytes". Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.

  10. The Association between Peritoneal Dialysis Modality and Peritonitis

    Science.gov (United States)

    Johnson, David W.; McDonald, Stephen P.; Boudville, Neil; Borlace, Monique; Badve, Sunil V.; Sud, Kamal; Clayton, Philip A.

    2014-01-01

    Background and objectives There is conflicting evidence comparing peritonitis rates among patients treated with continuous ambulatory peritoneal dialysis (CAPD) or automated peritoneal dialysis (APD). This study aims to clarify the relationship between peritoneal dialysis (PD) modality (APD versus CAPD) and the risk of developing PD-associated peritonitis. Design, setting, participants, & measurements This study examined the association between PD modality (APD versus CAPD) and the risks, microbiology, and clinical outcomes of PD-associated peritonitis in 6959 incident Australian PD patients between October 1, 2003, and December 31, 2011, using data from the Australia and New Zealand Dialysis and Transplant Registry. Median follow-up time was 1.9 years. Results Patients receiving APD were younger (60 versus 64 years) and had fewer comorbidities. There was no association between PD modality and time to first peritonitis episode (adjusted hazard ratio [HR] for APD versus CAPD, 0.98; 95% confidence interval [95% CI], 0.91 to 1.07; P=0.71). However, there was a lower hazard of developing Gram-positive peritonitis with APD than CAPD, which reached borderline significance (HR, 0.90; 95% CI, 0.80 to 1.00; P=0.05). No statistically significant difference was found in the risk of hospitalizations (odds ratio, 1.12; 95% CI, 0.93 to 1.35; P=0.22), but there was a nonsignificant higher likelihood of 30-day mortality (odds ratio, 1.33; 95% CI, 0.93 to 1.88; P=0.11) at the time of the first episode of peritonitis for patients receiving APD. For all peritonitis episodes (including subsequent episodes of peritonitis), APD was associated with lower rates of culture-negative peritonitis (incidence rate ratio [IRR], 0.81; 95% CI, 0.69 to 0.94; P=0.002) and higher rates of gram-negative peritonitis (IRR, 1.28; 95% CI, 1.13 to 1.46; P=0.01). Conclusions PD modality was not associated with a higher likelihood of developing peritonitis. However, APD was associated with a borderline

  11. Application of avalanche photodiode for soft X-ray pulse-height analyses in the Ht-7 tokamak

    CERN Document Server

    Shi Yue Jiang; Hu Li Qun; Sun Yan Jun; LiuSheng; Ling Bil

    2002-01-01

    An avalanche photodiode (APD) has been used as soft X-ray energy pulse-height analysis system for the measurement of the electron temperature on the HT-7 tokamak. The experimental results obtained with the APD with its inferior energy resolution show a little difference compared to the conventional high energy-resolution Si (Li) detector. Both numerical analysis and experimental results prove that the APD is good enough for application of the electron temperature measurement in tokamaks.

  12. Pulse oximeter using a gain-modulated avalanche photodiode operated in a pseudo lock-in light detection mode

    Science.gov (United States)

    Miyata, Tsuyoshi; Iwata, Tetsuo; Araki, Tsutomu

    2006-01-01

    We propose a reflection-type pulse oximeter, which employs two pairs of a light-emitting diode (LED) and a gated avalanche photodiode (APD). One LED is a red one with an emission wavelength λ = 635 nm and the other is a near-infrared one with that λ = 945 nm, which are both driven with a pulse mode at a frequency f (=10 kHz). Superposition of a transistor-transistor-logic (TTL) gate pulse on a direct-current (dc) bias, which is set so as not exceeding the breakdown voltage of each APD, makes the APD work in a gain-enhanced operation mode. Each APD is gated at a frequency 2f (=20 kHz) and its output signal is fed into a laboratory-made lock-in amplifier that works in synchronous with the pulse modulation signal of each LED at a frequency f (=10 kHz). A combination of the gated APD and the lock-in like signal detection scheme is useful for the reflection-type pulse oximeter thanks to the capability of detecting a weak signal against a large background (BG) light.

  13. Emergent Start Peritoneal Dialysis for End-Stage Renal Disease: Outcomes and Advantages.

    Science.gov (United States)

    Nayak, K Shivanand; Subhramanyam, Sreepada V; Pavankumar, Navva; Antony, Sinoj; Sarfaraz Khan, M A

    2018-01-01

    Initiating renal replacement therapy in late referred patients with central venous catheter (CVC) hemodialysis (HD) causes serious complications. In urgent start peritoneal dialysis, initiating peritoneal dialysis (PD) within 14 days of catheter insertion still needs HD with CVC. We initiated Emergent start PD (ESPD) with Automated PD (APD) at our center within 48 h from the time of presentation. A prospective, case-controlled, intention-to-treat study with 56 patients was conducted between March 2016 and August 2017. Group A (24 patients) underwent conventional PD 14 days after catheter insertion. Group B (32 patients), underwent ESPD with APD. Exit site leak (ESL), catheter blockage, and peritonitis at 90 days were primary outcomes. Technique survival was secondary outcome. Baseline characteristics were similar with 3 episodes of ESLs (9.4%) in the study group and none in the control group (p = 0.123). Catheter blockage (16.7%-Group A, 25%-Group B) and peritonitis (none vs. 9.4% in study group) were similar in terms of statistical details just as technique survival (95%-Group A, 88.2%-Group B at 90 days). ESPD with APD in the unplanned patient is an appropriate approach. © 2018 S. Karger AG, Basel.

  14. Heart rate variability alters cardiac repolarization and electromechanical dynamics.

    Science.gov (United States)

    Phadumdeo, Vrishti M; Weinberg, Seth H

    2018-04-07

    Heart rate continuously varies due to autonomic regulation, stochasticity in pacemaking, and circadian rhythm, collectively termed heart rate variability (HRV), during normal physiological conditions. Low HRV is clinically associated with an elevated risk of cardiac arrhythmias. Alternans, a beat-to-beat alternation in action potential duration (APD) and/or intracellular calcium (Ca) transient, is a well-known risk factor associated with cardiac arrhythmias that is typically studied under conditions of a constant pacing rate, i.e., the absence of HRV. In this study, we investigate the effects of HRV on the interplay between APD, Ca, and electromechanical properties, employing a nonlinear discrete-time map model that governs APD and intracellular Ca cycling with a stochastic pacing period. We find that HRV can decrease variation in APD and peak Ca at fast pacing rates for which alternans is present. Further, increased HRV typically disrupts the alternating pattern for both APD and peak Ca and weakens the correlation between APD and peak Ca, thus decoupling Ca-mediated instabilities from repolarization alternation. We find that the efficacy of these effects is regulated by the sarcoplasmic reticulum Ca uptake rate. Overall, these results demonstrate that HRV disrupts arrhythmogenic alternans and suggests that HRV may be a significant factor in preventing life-threatening arrhythmias. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Relation between Working Memory Capacity and Auditory Stream Segregation in Children with Auditory Processing Disorder.

    Science.gov (United States)

    Lotfi, Yones; Mehrkian, Saiedeh; Moossavi, Abdollah; Zadeh, Soghrat Faghih; Sadjedi, Hamed

    2016-03-01

    This study assessed the relationship between working memory capacity and auditory stream segregation by using the concurrent minimum audible angle in children with a diagnosed auditory processing disorder (APD). The participants in this cross-sectional, comparative study were 20 typically developing children and 15 children with a diagnosed APD (age, 9-11 years) according to the subtests of multiple-processing auditory assessment. Auditory stream segregation was investigated using the concurrent minimum audible angle. Working memory capacity was evaluated using the non-word repetition and forward and backward digit span tasks. Nonparametric statistics were utilized to compare the between-group differences. The Pearson correlation was employed to measure the degree of association between working memory capacity and the localization tests between the 2 groups. The group with APD had significantly lower scores than did the typically developing subjects in auditory stream segregation and working memory capacity. There were significant negative correlations between working memory capacity and the concurrent minimum audible angle in the most frontal reference location (0° azimuth) and lower negative correlations in the most lateral reference location (60° azimuth) in the children with APD. The study revealed a relationship between working memory capacity and auditory stream segregation in children with APD. The research suggests that lower working memory capacity in children with APD may be the possible cause of the inability to segregate and group incoming information.

  16. Degradation and Its Control of Ultraviolet Avalanche Photodiodes Using PEDOT:PSS/ZnSSe Organic-Inorganic Hybrid Structure

    Science.gov (United States)

    Abe, Tomoki; Uchida, Shigeto; Tanaka, Keita; Fujisawa, Takanobu; Kasada, Hirofumi; Ando, Koshi; Akaiwa, Kazuaki; Ichino, Kunio

    2018-05-01

    We investigated device degradation in PEDOT:PSS/ZnSSe organic-inorganic hybrid ultraviolet avalanche photodiodes (UV-APDs). ZnSSe/n-GaAs wafers were grown by molecular beam epitaxy, and PEDOT:PSS window layers were formed by inkjet technique. We observed rapid degradation with APD-mode stress (˜ 30 V) in the N2 (4 N) atmosphere, while we observed no marked change in forward bias current stress and photocurrent stress. In the case of a vacuum condition, we observed no detectable degradation in the dark avalanche current with APD-mode stress. Therefore, the degradation in the PEDOT:PSS/ZnSSe interface under the APD-mode stress was caused by the residual water vapor or oxygen in the N2 atmosphere and could be controlled by vacuum packaging.

  17. New Very Low Noise Multilayer And Graded-Gap Avalanche Photodiodes For The 0.8 To 1 .8 μm Wavelength Region

    Science.gov (United States)

    Capasso, F.; Tsang, W. T.; Williams, G. F.

    1982-12-01

    Recent experimental and theoretical results on a new class of low noise avalanche photo-diodes are reviewed. A large enhancement of the impact ionization rates ratio (a/(3=10) has been demonstrated in AlGaAs/GaAs superlattices and graded band gap detector structures. In addition two novel photodiodes ("staircase" and "channeling" APDs) where only electrons multiply, have been proposed. The staircase APD is the solid state analog of the photo-multiplier with discrete dynodes. It has a low operating voltage (5-20 volts) and a lower excess noise factor, in the ideal case, than that of an ideal conventional APD The channeling APD is instead the solid state analog of a channeltron photomultiplier and has the unique feature of an ultrahigh a/β, ratio (≍∞) compatible with high gain (>100).

  18. Sympathetic Nervous Regulation of Calcium and Action Potential Alternans in the Intact Heart.

    Science.gov (United States)

    Winter, James; Bishop, Martin J; Wilder, Catherine D E; O'Shea, Christopher; Pavlovic, Davor; Shattock, Michael J

    2018-01-01

    Rationale: Arrhythmogenic cardiac alternans are thought to be an important determinant for the initiation of ventricular fibrillation. There is limited information on the effects of sympathetic nerve stimulation (SNS) on alternans in the intact heart and the conclusions of existing studies, focused on investigating electrical alternans, are conflicted. Meanwhile, several lines of evidence implicate instabilities in Ca handling, not electrical restitution, as the primary mechanism underpinning alternans. Despite this, there have been no studies on Ca alternans and SNS in the intact heart. The present study sought to address this, by application of voltage and Ca optical mapping for the simultaneous study of APD and Ca alternans in the intact guinea pig heart during direct SNS. Objective : To determine the effects of SNS on APD and Ca alternans in the intact guinea pig heart and to examine the mechanism(s) by which the effects of SNS are mediated. Methods and Results : Studies utilized simultaneous voltage and Ca optical mapping in isolated guinea pig hearts with intact innervation. Alternans were induced using a rapid dynamic pacing protocol. SNS was associated with rate-independent shortening of action potential duration (APD) and the suppression of APD and Ca alternans, as indicated by a shift in the alternans threshold to faster pacing rates. Qualitatively similar results were observed with exogenous noradrenaline perfusion. In contrast with previous reports, both SNS and noradrenaline acted to flatten the slope of the electrical restitution curve. Pharmacological block of the slow delayed rectifying potassium current (I Ks ), sufficient to abolish I Ks -mediated APD-adaptation, partially reversed the effects of SNS on pacing-induced alternans. Treatment with cyclopiazonic acid, an inhibitor of the sarco(endo)plasmic reticulum ATPase, had opposite effects to that of SNS, acting to increase susceptibility to alternans, and suggesting that accelerated Ca reuptake

  19. Differential effects of thioridazine enantiomers on action potential duration in rabbit papillary muscle

    DEFF Research Database (Denmark)

    Jensen, Ask Schou; Pennisi, Cristian Pablo; Sevcencu, Cristian

    2015-01-01

    with (+)-thioridazine. In this study we for the first time investigate the cardiotoxicity of the isolated thioridazine enantiomers and show their effects on ventricular repolarization. The effects of (+)-thioridazine, (-)-thioridazine, and racemate on the rabbit ventricular action potential duration (APD) were...... investigated in a randomized controlled blinded experiment. Action potentials were measured in papillary muscles isolated from 21 female rabbits, and the drug effect on 90% APD in comparison with control (DeltaDelta-APD90) was evaluated. Increasing concentrations of (+)-thioridazine and the racemate caused...

  20. A prototype high-resolution animal positron tomograph with avalanche photodiode arrays and LSO crystals

    International Nuclear Information System (INIS)

    Ziegler, S.I.; Pichler, B.J.; Rafecas, M.; Schwaiger, M.

    2001-01-01

    To fully utilize positron emission tomography (PET) as a non-invasive tool for tissue characterization, dedicated instrumentation is being developed which is specially suited for imaging mice and rats. Semiconductor detectors, such as avalanche photodiodes (APDs), may offer an alternative to photomultiplier tubes for the readout of scintillation crystals. Since the scintillation characteristics of lutetium oxyorthosilicate (LSO) are well matched to APDs, the combination of LSO and APDs seems favourable, and the goal of this study was to build a positron tomograph with LSO-APD modules to prove the feasibility of such an approach. A prototype PET scanner based on APD readout of small, individual LSO crystals was developed for tracer studies in mice and rats. The tomograph consists of two sectors (86 mm distance), each comprising three LSO-APD modules, which can be rotated for the acquisition of complete projections. In each module, small LSO crystals (3.7 x 3.7 x 12 mm 3 ) are individually coupled to one channel within matrices containing 2 x 8 square APDs (2.6 x 2.6 mm 2 sensitive area per channel). The list-mode data are reconstructed with a penalized weighted least squares algorithm which includes the spatially dependent line spread function of the tomograph. Basic performance parameters were measured with phantoms and first experiments with rats and mice were conducted to introduce this methodology for biomedical imaging. The reconstructed field of view covers 68 mm, which is 80% of the total detector diameter. Image resolution was shown to be 2.4 mm within the whole reconstructed field of view. Using a lower energy threshold of 450 keV, the system sensitivity was 350 Hz/MBq for a line source in air in the centre of the field of view. In a water-filled cylinder of 4.6 cm diameter, the scatter fraction at the centre of the field of view was 16% (450 keV threshold). The count rate was linear up to 700 coincidence counts per second. In vivo studies of anaesthetized

  1. An integrated fluorescence detection system in poly(dimethylsiloxane) for microfluidic applications.

    Science.gov (United States)

    Chabinyc, M L; Chiu, D T; McDonald, J C; Stroock, A D; Christian, J F; Karger, A M; Whitesides, G M

    2001-09-15

    This paper describes a prototype of an integrated fluorescence detection system that uses a microavalanche photodiode (microAPD) as the photodetector for microfluidic devices fabricated in poly(dimethylsiloxane) (PDMS). The prototype device consisted of a reusable detection system and a disposable microfluidic system that was fabricated using rapid prototyping. The first step of the procedure was the fabrication of microfluidic channels in PDMS and the encapsulation of a multimode optical fiber (100-microm core diameter) in the PDMS; the tip of the fiber was placed next to the side wall of one of the channels. The optical fiber was used to couple light into the microchannel for the excitation of fluorescent analytes. The photodetector, a prototype solid-state microAPD array, was embedded in a thick slab (1 cm) of PDMS. A thin (80 microm) colored polycarbonate filter was placed on the top of the embedded microAPD to absorb scattered excitation light before it reached the detector. The microAPD was placed below the microchannel and orthogonal to the axis of the optical fiber. The close proximity (approximately 200 microm) of the microAPD to the microchannel made it unnecessary to incorporate transfer optics; the pixel size of the microAPD (30 microm) matched the dimensions of the channels (50 microm). A blue light-emitting diode was used for fluorescence excitation. The microAPD was operated in Geiger mode to detect the fluorescence. The detection limit of the prototype (approximately 25 nM) was determined by finding the minimum detectable concentration of a solution of fluorescein. The device was used to detect the separation of a mixture of proteins and small molecules by capillary electrophoresis; the separation illustrated the suitability of this integrated fluorescence detection system for bioanalytical applications.

  2. Electrophysiological effects of Chinese medicine Shen song Yang xin (SSYX) on Chinese miniature swine heart and isolated guinea pig ventricular myocytes.

    Science.gov (United States)

    Feng, Li; Gong, Jing; Jin, Zhen-yi; Li, Ning; Sun, Li-ping; Wu, Yi-ling; Pu, Jie-lin

    2009-07-05

    Shen song Yang xin (SSYX) is a compound of Chinese medicine with the effect of increasing heart rate (HR). This study aimed to evaluate its electrophysiological properties at heart and cellular levels. The Chinese miniature swines were randomly assigned to two groups, administered with SSYX or placebo for 4 weeks (n = 8 per group). Cardiac electrophysiological study (EPS) was performed before and after drug administration. The guinea pig ventricular myocytes were enzymatically isolated and whole cell voltage-clamp technique was used to evaluate the effect of SSYX on cardiac action potential (AP). SSYX treatment accelerated the HR from (141.8 +/- 36.0) beats per minute to (163.0 +/- 38.0) beats per minute (P = 0.013) without changing the other parameters in surface electrocardiogram. After blockage of the autonomic nervous system with metoprolol and atropin, SSYX had no effect on intrinsic HR (IHR), but decreased corrected sinus node recovery time (CSNRT) and sinus atrium conducting time (SACT). Intra cardiac EPS showed that SSYX significantly decreased the A-H and A-V intervals as well as shortened the atrial (A), atrioventricular node (AVN) and ventricular (V) effective refractory period (ERP). In isolated guinea pig ventricular myocytes, the most obvious effect of SSYX on action potential was a shortening of the action potential duration (APD) without change in shape of action potential. The shortening rates of APD(30), APD(50) and APD(90) were 19.5%, 17.8% and 15.3%, respectively. The resting potential (Em) and the interval between the end of APD(30) and APD(90) did not significantly change. The present study demonstrates that SSYX increases the HR and enhances the conducting capacity of the heart in the condition of the intact autonomic nervous system. SSYX homogenously decreases the ERP of the heart and shortens the APD of the myocytes, suggesting its antiarrhythmic effect without proarrhythmia.

  3. Arrhythmogenic drugs can amplify spatial heterogeneities in the electrical restitution in perfused guinea-pig heart: An evidence from assessments of monophasic action potential durations and JT intervals.

    Directory of Open Access Journals (Sweden)

    Oleg E Osadchii

    Full Text Available Non-uniform shortening of the action potential duration (APD90 in different myocardial regions upon heart rate acceleration can set abnormal repolarization gradients and promote arrhythmia. This study examined whether spatial heterogeneities in APD90 restitution can be amplified by drugs with clinically proved proarrhythmic potential (dofetilide, quinidine, procainamide, and flecainide and, if so, whether these effects can translate to the appropriate changes of the ECG metrics of ventricular repolarization, such as JT intervals. In isolated, perfused guinea-pig heart preparations, monophasic action potentials and volume-conducted ECG were recorded at progressively increased pacing rates. The APD90 measured at distinct ventricular sites, as well as the JTpeak and JTend values were plotted as a function of preceding diastolic interval, and the maximum slopes of the restitution curves were determined at baseline and upon drug administration. Dofetilide, quinidine, and procainamide reverse rate-dependently prolonged APD90 and steepened the restitution curve, with effects being greater at the endocardium than epicardium, and in the right ventricular (RV vs. the left ventricular (LV chamber. The restitution slope was increased to a greater extent for the JTend vs. the JTpeak interval. In contrast, flecainide reduced the APD90 restitution slope at LV epicardium without producing effect at LV endocardium and RV epicardium, and reduced the JTpeak restitution slope without changing the JTend restitution. Nevertheless, with all agents, these effects translated to the amplified epicardial-to-endocardial and the LV-to-RV non-uniformities in APD90 restitution, paralleled by the increased JTend vs. JTpeak difference in the restitution slope. In summary, these findings suggest that arrhythmic drug profiles are partly attributable to the accentuated regional heterogeneities in APD90 restitution, which can be indirectly determined through ECG assessments of the

  4. Arrhythmogenic drugs can amplify spatial heterogeneities in the electrical restitution in perfused guinea-pig heart: An evidence from assessments of monophasic action potential durations and JT intervals.

    Science.gov (United States)

    Osadchii, Oleg E

    2018-01-01

    Non-uniform shortening of the action potential duration (APD90) in different myocardial regions upon heart rate acceleration can set abnormal repolarization gradients and promote arrhythmia. This study examined whether spatial heterogeneities in APD90 restitution can be amplified by drugs with clinically proved proarrhythmic potential (dofetilide, quinidine, procainamide, and flecainide) and, if so, whether these effects can translate to the appropriate changes of the ECG metrics of ventricular repolarization, such as JT intervals. In isolated, perfused guinea-pig heart preparations, monophasic action potentials and volume-conducted ECG were recorded at progressively increased pacing rates. The APD90 measured at distinct ventricular sites, as well as the JTpeak and JTend values were plotted as a function of preceding diastolic interval, and the maximum slopes of the restitution curves were determined at baseline and upon drug administration. Dofetilide, quinidine, and procainamide reverse rate-dependently prolonged APD90 and steepened the restitution curve, with effects being greater at the endocardium than epicardium, and in the right ventricular (RV) vs. the left ventricular (LV) chamber. The restitution slope was increased to a greater extent for the JTend vs. the JTpeak interval. In contrast, flecainide reduced the APD90 restitution slope at LV epicardium without producing effect at LV endocardium and RV epicardium, and reduced the JTpeak restitution slope without changing the JTend restitution. Nevertheless, with all agents, these effects translated to the amplified epicardial-to-endocardial and the LV-to-RV non-uniformities in APD90 restitution, paralleled by the increased JTend vs. JTpeak difference in the restitution slope. In summary, these findings suggest that arrhythmic drug profiles are partly attributable to the accentuated regional heterogeneities in APD90 restitution, which can be indirectly determined through ECG assessments of the JTend vs. JTpeak

  5. The fear of being laughed at as additional diagnostic criterion in social anxiety disorder and avoidant personality disorder?

    Science.gov (United States)

    Havranek, Michael M; Volkart, Fleur; Bolliger, Bianca; Roos, Sophie; Buschner, Maximilian; Mansour, Ramin; Chmielewski, Thomas; Gaudlitz, Katharina; Hättenschwiler, Josef; Seifritz, Erich; Ruch, Willibald

    2017-01-01

    Social anxiety disorder (SAD) is the most common anxiety disorder and has considerable negative impact on social functioning, quality of life, and career progression of those affected. Gelotophobia (the fear of being laughed at) shares many similarities and has therefore been proposed as a subtype of SAD. This hypothesis has, however, never been tested in a clinical sample. Thus, the relationship between gelotophobia, SAD and avoidant personality disorder (APD) was investigated by examining a sample of 133 participants (64 psychiatric patients and 69 healthy controls matched for age and sex) using the Structured Clinical Interview for the Diagnostic and Statistical Manual of Mental Disorders (4th edition) and an established rating instrument for gelotophobia (GELOPH). As expected, gelotophobia scores and the number of gelotophobic individuals were significantly higher among patients with SAD (n = 22) and APD (n = 12) compared to healthy controls and other psychiatric patients. Furthermore, gelotophobia scores were highest in patients suffering from both SAD and APD. In fact, all patients suffering from both disorders were also suffering from gelotophobia. As explained in the discussion, the observed data did not suggest that gelotophobia is a subtype of SAD. The findings rather imply that the fear of being laughed at is a symptom characteristic for both SAD and APD. Based on that, gelotophobia may prove to be a valuable additional diagnostic criterion for SAD and APD and the present results also contribute to the ongoing debate on the relationship between SAD and APD.

  6. Relation between Working Memory Capacity and Auditory Stream Segregation in Children with Auditory Processing Disorder

    Directory of Open Access Journals (Sweden)

    Yones Lotfi

    2016-03-01

    Full Text Available Background: This study assessed the relationship between working memory capacity and auditory stream segregation by using the concurrent minimum audible angle in children with a diagnosed auditory processing disorder (APD. Methods: The participants in this cross-sectional, comparative study were 20 typically developing children and 15 children with a diagnosed APD (age, 9–11 years according to the subtests of multiple-processing auditory assessment. Auditory stream segregation was investigated using the concurrent minimum audible angle. Working memory capacity was evaluated using the non-word repetition and forward and backward digit span tasks. Nonparametric statistics were utilized to compare the between-group differences. The Pearson correlation was employed to measure the degree of association between working memory capacity and the localization tests between the 2 groups. Results: The group with APD had significantly lower scores than did the typically developing subjects in auditory stream segregation and working memory capacity. There were significant negative correlations between working memory capacity and the concurrent minimum audible angle in the most frontal reference location (0° azimuth and lower negative correlations in the most lateral reference location (60° azimuth in the children with APD. Conclusion: The study revealed a relationship between working memory capacity and auditory stream segregation in children with APD. The research suggests that lower working memory capacity in children with APD may be the possible cause of the inability to segregate and group incoming information.

  7. The fear of being laughed at as additional diagnostic criterion in social anxiety disorder and avoidant personality disorder?

    Directory of Open Access Journals (Sweden)

    Michael M Havranek

    Full Text Available Social anxiety disorder (SAD is the most common anxiety disorder and has considerable negative impact on social functioning, quality of life, and career progression of those affected. Gelotophobia (the fear of being laughed at shares many similarities and has therefore been proposed as a subtype of SAD. This hypothesis has, however, never been tested in a clinical sample. Thus, the relationship between gelotophobia, SAD and avoidant personality disorder (APD was investigated by examining a sample of 133 participants (64 psychiatric patients and 69 healthy controls matched for age and sex using the Structured Clinical Interview for the Diagnostic and Statistical Manual of Mental Disorders (4th edition and an established rating instrument for gelotophobia (GELOPH. As expected, gelotophobia scores and the number of gelotophobic individuals were significantly higher among patients with SAD (n = 22 and APD (n = 12 compared to healthy controls and other psychiatric patients. Furthermore, gelotophobia scores were highest in patients suffering from both SAD and APD. In fact, all patients suffering from both disorders were also suffering from gelotophobia. As explained in the discussion, the observed data did not suggest that gelotophobia is a subtype of SAD. The findings rather imply that the fear of being laughed at is a symptom characteristic for both SAD and APD. Based on that, gelotophobia may prove to be a valuable additional diagnostic criterion for SAD and APD and the present results also contribute to the ongoing debate on the relationship between SAD and APD.

  8. Comparison of relative and actual chest compression depths during cardiac arrest in children, adolescents, and young adults☆

    Science.gov (United States)

    Niles, Dana E.; Nishisaki, Akira; Sutton, Robert M.; Nysæther, Jon; Eilevstjønn, Joar; Leffelman, Jessica; Maltese, Matthew R.; Arbogast, Kristy B.; Abella, Benjamin S.; Helfaer, Mark A.; Berg, Robert A.; Nadkarni, Vinay M.

    2013-01-01

    Aim Cardiopulmonary resuscitation (CPR) guidelines recommend specific chest compression (CC) target depths for children. We quantitatively describe relative anterior–posterior diameter (APD) depth, actual depth, and force of CCs during real CPR events in children. Methods CC depth and force were recorded during real CPR events in children ≥8 years using FDA-approved CC sensor. Patient chest APD was measured at conclusion of each CPR event. CC data was stratified and analyzed according to age (pre-puberty, 8–14 years; post-puberty, 15+ years). Relative (% APD) and actual CC depth, corrected for mattress deflection, were assessed and compared with American Heart Association (AHA) 2005 and 2010 pediatric CPR guidelines. Results 35 events in 32 subjects included 16,158 CCs for data analysis: 16 pre-puberty (CCs = 7484, age 11.9 ± 2 years, APD 164.6 ± 25.1 mm); 19 post-puberty (CCs = 8674, age 18.0 ± 2.7 years, APD 196.5 ± 30.4 mm). After correction for mattress deflection, 92% of CC delivered to pre-puberty were resuscitation teams were frequently <1/3 relative APD and <38 mm actual depth after mattress deflection correction, below pediatric and adult target guidelines. Mean CC actual depth and force were not significantly different in pre-puberty and post-puberty. Additional investigation to determine depth of CCs to optimize hemodynamics and outcomes is needed to inform future CPR guidelines. PMID:22079410

  9. Development of an integrated four-channel fast avalanche-photodiode detector system with nanosecond time resolution

    Science.gov (United States)

    Li, Zhenjie; Li, Qiuju; Chang, Jinfan; Ma, Yichao; Liu, Peng; Wang, Zheng; Hu, Michael Y.; Zhao, Jiyong; Alp, E. E.; Xu, Wei; Tao, Ye; Wu, Chaoqun; Zhou, Yangfan

    2017-10-01

    A four-channel nanosecond time-resolved avalanche-photodiode (APD) detector system is developed at Beijing Synchrotron Radiation. It uses a single module for signal processing and readout. This integrated system provides better reliability and flexibility for custom improvement. The detector system consists of three parts: (i) four APD sensors, (ii) four fast preamplifiers and (iii) a time-digital-converter (TDC) readout electronics. The C30703FH silicon APD chips fabricated by Excelitas are used as the sensors of the detectors. It has an effective light-sensitive area of 10 × 10 mm2 and an absorption layer thickness of 110 μm. A fast preamplifier with a gain of 59 dB and bandwidth of 2 GHz is designed to readout of the weak signal from the C30703FH APD. The TDC is realized by a Spartan-6 field-programmable-gate-array (FPGA) with multiphase method in a resolution of 1ns. The arrival time of all scattering events between two start triggers can be recorded by the TDC. The detector has been used for nuclear resonant scattering study at both Advanced Photon Source and also at Beijing Synchrotron Radiation Facility. For the X-ray energy of 14.4 keV, the time resolution, the full width of half maximum (FWHM) of the detector (APD sensor + fast amplifier) is 0.86 ns, and the whole detector system (APD sensors + fast amplifiers + TDC readout electronics) achieves a time resolution of 1.4 ns.

  10. Differential effects of psychopathy and antisocial personality disorder symptoms on cognitive and fear processing in female offenders.

    Science.gov (United States)

    Anton, Marja E; Baskin-Sommers, Arielle R; Vitale, Jennifer E; Curtin, John J; Newman, Joseph P

    2012-12-01

    Psychopathy and antisocial personality disorder (APD) have long been considered important risk factors for criminal behavior and incarceration. However, little is known about the psychobiological underpinnings that give rise to the disinhibited behavior of female offenders. Using an instructed fear-conditioning paradigm and a sample of incarcerated female offenders, we manipulated attentional focus and cognitive load to characterize and differentiate between the dysfunctional cognitive and affective processes associated with these syndromes. We used fear-potentiated startle (FPS) and event-related potentials as measures of affective and cognitive processing, respectively. After controlling for APD symptoms, psychopathic women displayed greater FPS while attending directly to threat-relevant stimuli and displayed less FPS while performing a demanding task that directed attention to threat-irrelevant information. Conversely, controlling for psychopathy, women with high APD symptoms displayed less overall FPS, especially when instructed to focus on threat-relevant stimuli. However, as the demands on cognitive resources increased, they displayed greater FPS. For both psychopathy and APD, analysis of the event-related potentials qualified these findings and further specified the abnormal cognitive processes associated with these two syndromes. Overall, simultaneous analysis of psychopathy and APD revealed distinct patterns of cognitive processing and fear reactivity.

  11. Geiger mode avalanche photodiodes for microarray systems

    Science.gov (United States)

    Phelan, Don; Jackson, Carl; Redfern, R. Michael; Morrison, Alan P.; Mathewson, Alan

    2002-06-01

    New Geiger Mode Avalanche Photodiodes (GM-APD) have been designed and characterized specifically for use in microarray systems. Critical parameters such as excess reverse bias voltage, hold-off time and optimum operating temperature have been experimentally determined for these photon-counting devices. The photon detection probability, dark count rate and afterpulsing probability have been measured under different operating conditions. An active- quench circuit (AQC) is presented for operating these GM- APDs. This circuit is relatively simple, robust and has such benefits as reducing average power dissipation and afterpulsing. Arrays of these GM-APDs have already been designed and together with AQCs open up the possibility of having a solid-state microarray detector that enables parallel analysis on a single chip. Another advantage of these GM-APDs over current technology is their low voltage CMOS compatibility which could allow for the fabrication of an AQC on the same device. Small are detectors have already been employed in the time-resolved detection of fluorescence from labeled proteins. It is envisaged that operating these new GM-APDs with this active-quench circuit will have numerous applications for the detection of fluorescence in microarray systems.

  12. The impact of thermal loading on repository performance at Yucca Mountain

    International Nuclear Information System (INIS)

    Buscheck, T.A.; Nitao, J.J.

    1992-01-01

    In the unsaturated zone at Yucca Mountain, liquid flow along preferential fracture pathways is the only credible mechanism capable of bringing water to waste packages and transporting radionuclide to the water table. Three categories of features or mechanisms will mitigate the impact of flow along preferential fracture pathways: (1) discontinuity in fracture pathways, (2) liquid-phase dispersion in fracture networks, and (3) fracture-matrix interaction. For repository areal power densities (APDs) that are too low to result in significant boiling or rock dry-out effects, the primary mode of fracture-matrix interaction is matrix imbibition. For high APDs, boiling and enhanced matrix imbibition due to rock dry-out significantly add to the capacity of the unsaturated zone to retard fracture-dominated flow. With the use of V-TOUGH code, hydrothermal flow calculations are made for a range of APDs and spent fuel ages. For APD > 20 kW/acre, repository-heat-generated flow of vapor and liquid in fractures is found to dominate the ambient hydrological system. For high APDs, boiling conditions can persist for 10,000 yr or longer and rock-dry benefits for at least 100,000 yr

  13. Avalanche photodiode based time-of-flight mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Ogasawara, Keiichi, E-mail: kogasawara@swri.edu; Livi, Stefano A.; Desai, Mihir I.; Ebert, Robert W.; McComas, David J.; Walther, Brandon C. [Southwest Research Institute, 6220 Culebra Road, San Antonio, Texas 78238 (United States)

    2015-08-15

    This study reports on the performance of Avalanche Photodiodes (APDs) as a timing detector for ion Time-of-Flight (TOF) mass spectroscopy. We found that the fast signal carrier speed in a reach-through type APD enables an extremely short timescale response with a mass or energy independent <2 ns rise time for <200 keV ions (1−40 AMU) under proper bias voltage operations. When combined with a microchannel plate to detect start electron signals from an ultra-thin carbon foil, the APD comprises a novel TOF system that successfully operates with a <0.8 ns intrinsic timing resolution even using commercial off-the-shelf constant-fraction discriminators. By replacing conventional total-energy detectors in the TOF-Energy system, APDs offer significant power and mass savings or an anti-coincidence background rejection capability in future space instrumentation.

  14. Psychopathy, Antisocial Personality Disorder, and Reconviction in an Australian Sample of Forensic Patients.

    Science.gov (United States)

    Shepherd, Stephane M; Campbell, Rachel E; Ogloff, James R P

    2018-02-01

    This study identified the presence of psychopathy (as measured by the PCL-R/PCL:SV instruments) and antisocial personality disorder (APD) and their relationship with future reconviction in an Australian forensic sample ( N = 136) of patients with a mental disorder. Patients were tracked for over 4 years postrelease to determine associations between a diagnosis of APD/psychopathy and reoffense. Patients with higher psychopathy scores were found to have an increased likelihood of reincarceration, a higher rate of reconviction, and were reconvicted earlier compared with patients with lower psychopathy scores. Patients with APD were more likely to be reconvicted and reincarcerated during the follow-up period than patients without an APD diagnosis. Despite demonstrating associations with general reconviction, the PCL instruments did not exhibit statistically significant relationships with violence. Implications for the clinical identification of personality disordered patients in forensic settings are discussed.

  15. Gender differences in contributions of emotion to psychopathy and antisocial personality disorder.

    Science.gov (United States)

    Rogstad, Jill E; Rogers, Richard

    2008-12-01

    Traditional conceptualizations of psychopathy highlight the importance of affective features as they relate to social deviance; however, little empirical research has actually investigated specific roles of emotion and emotion processing with respect to antisocial conduct. Antisocial personality disorder (APD), prevalent in forensic populations, is commonly associated with psychopathy despite the notable omission of such core affective features in its diagnosis. In this paper, we review the empirical literature on the contribution of emotion to psychopathy and APD, highlighting in particular research on emotion processing and various facets of emotional expression, including empathy and alexithymia. Research findings are discussed on gender differences in emotional functioning and their likely effects on the assessment of psychopathy and APD. Given the known gender differences in the expressions of emotion, the article concludes with recommendations to bridge research for different offender groups, including psychopathy and APD.

  16. Treatment with antidepressants and lithium is associated with increased risk of treatment with antiparkinson drugs: a pharmacoepidemiological study

    DEFF Research Database (Denmark)

    Brandt-Christensen, Anne Mette; Kvist, Tine Kajsa; Nielsen, F.M.

    2006-01-01

    OBJECTIVE: To estimate the risk for persons treated with antidepressants or lithium of subsequent treatment with antiparkinson drugs (APD). METHODS: The Danish national prescription database supplied data on all persons who received antidepressants, lithium, or antidiabetics (first control group......). A second control group was included comprising persons from the general population. Outcome was purchase of APD and the study period was 1995 to 1999. RESULTS: In total, 1 293 789 persons were included. The rate ratio of treatment with APD after treatment with antidepressants was 2.27 (95% CI 2.14 to 2.......42) for men and 1.50 (95% CI 1.43 to 1.58) for women. Figures for lithium were almost identical. CONCLUSION: Persons treated with antidepressants or lithium are at increased risk of subsequently treatment with APD, showing an association between anxiety/affective disorder and Parkinson's disease....

  17. Anti-arrhythmic peptide N-3-(4-hydroxyphenyl)propionyl Pro-Hyp-Gly-Ala-Gly-OH reduces dispersion of action potential duration during ischemia/reperfusion in rabbit hearts

    DEFF Research Database (Denmark)

    Kjølbye, Anne Louise; Petersen, Jørgen Søberg; Holstein-Rathlou, N.-H.

    2002-01-01

    During ischemia, cardiac gap junctions close and neighboring cells uncouple. This leads to slow conduction, increased dispersion of APD90 (duration from action potential beginning to 90% of repolarization), nonuniform anisotropy, and unidirectional conduction block, all of which favor the induction...... of reentry arrhythmias. It has been suggested that anti-arrhythmic peptides increase gap junction conductance during states of reduced coupling. The aim of this study was to test the effect of the anti-arrhythmic peptide N-3-(4-hydroxyphenyl)propionyl Pro-Hyp-Gly-Ala-Gly-OH (HP-5) (10(-10) ) on dispersion...... of epicardial APD90 during both normokalemic and hypokalemic ischemia/reperfusion in isolated perfused rabbit hearts. HP-5 did not affect average APD90, heart rate, left ventricular contractility (LVP dP/dtmax), or mean coronary flow. HP-5 significantly reduced the epicardial APD dispersion during hypokalemic...

  18. HgCdTe Avalanche Photodiode Detectors for Airborne and Spaceborne Lidar at Infrared Wavelengths

    Science.gov (United States)

    Sun, Xiaoli; Abshire, James B.; Beck, Jeffrey D.; Mitra, Pradip; Reiff, Kirk; Yang, Guangning

    2017-01-01

    We report results from characterizing the HgCdTe avalanche photodiode (APD) sensorchip assemblies (SCA) developed for lidar at infrared wavelength using the high density vertically integrated photodiodes (HDVIP) technique. These devices demonstrated high quantum efficiency, typically greater than 90 between 0.8 micrometers and the cut-off wavelength, greater than 600 APD gain, near unity excess noise factor, 6-10 MHz electrical bandwidth and less than 0.5 fW/Hz(exp.1/2) noise equivalent power (NEP). The detectors provide linear analog output with a dynamic range of 2-3 orders of magnitude at a fixed APD gain without averaging, and over 5 orders of magnitude by adjusting the APD and preamplifier gain settings. They have been successfully used in airborne CO2 and CH4 integrated path differential absorption (IPDA) lidar as a precursor for space lidar applications.

  19. Characterisation of Geiger-mode avalanche photodiodes for medical imaging applications

    Energy Technology Data Exchange (ETDEWEB)

    Britvitch, I. [Swiss Federal Institute of Technology, CH-8092 Zurich (Switzerland)]. E-mail: Ilia.britvitch@psi.ch; Johnson, I. [Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation); Renker, D. [Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); Stoykov, A. [Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation); Lorenz, E. [Swiss Federal Institute of Technology, CH-8092 Zurich (Switzerland); Max Planck Institute for Physics, 80805 Munich (Germany)

    2007-02-01

    Recently developed multipixel Geiger-mode avalanche photodiodes (G-APDs) are very promising candidates for the detection of light in medical imaging instruments (e.g. positron emission tomography) as well as in high-energy physics experiments and astrophysical applications. G-APDs are especially well suited for morpho-functional imaging (multimodality PET/CT, SPECT/CT, PET/MRI, SPECT/MRI). G-APDs have many advantages compared to conventional photosensors such as photomultiplier tubes because of their compact size, low-power consumption, high quantum efficiency and insensitivity to magnetic fields. Compared to avalanche photodiodes and PIN diodes, they are advantageous because of their high gain, reduced sensitivity to pick up and the so-called nuclear counter effect and lower noise. We present measurements of the basic G-APD characteristics: photon detection efficiency, gain, inter-cell crosstalk, dynamic range, recovery time and dark count rate.

  20. Characterisation of Geiger-mode avalanche photodiodes for medical imaging applications

    International Nuclear Information System (INIS)

    Britvitch, I.; Johnson, I.; Renker, D.; Stoykov, A.; Lorenz, E.

    2007-01-01

    Recently developed multipixel Geiger-mode avalanche photodiodes (G-APDs) are very promising candidates for the detection of light in medical imaging instruments (e.g. positron emission tomography) as well as in high-energy physics experiments and astrophysical applications. G-APDs are especially well suited for morpho-functional imaging (multimodality PET/CT, SPECT/CT, PET/MRI, SPECT/MRI). G-APDs have many advantages compared to conventional photosensors such as photomultiplier tubes because of their compact size, low-power consumption, high quantum efficiency and insensitivity to magnetic fields. Compared to avalanche photodiodes and PIN diodes, they are advantageous because of their high gain, reduced sensitivity to pick up and the so-called nuclear counter effect and lower noise. We present measurements of the basic G-APD characteristics: photon detection efficiency, gain, inter-cell crosstalk, dynamic range, recovery time and dark count rate

  1. Application of An Avalanche Photodiode in Synchrotron-Based Ultra-fast X-Radiography

    International Nuclear Information System (INIS)

    Cheong, S.-K.; Liu Jinyuan; Wang Jin; Powell, Christopher F.

    2004-01-01

    A possibility of using avalanche photodiode has been investigated while operated in current or continuous wave mode to accommodate high-intensity synchrotron x-ray beams in an ultra-fast x-radiography. To achieve a time resolution of 1 μs or better in a time-resolved x-radiograhic experiment, the entire time-sequence of the APD response to the pulsed synchrotron x-ray beam is recorded with time resolution of 1-2 ns. We have characterized the APD detector in the continuous wave mode to reveal its linearity, signal to noise ratio, and the time response with various circuit configurations. We have demonstrated that signal-to-noise ratio better than 1000 can be achieved, which is limited only by Poisson statistics. These detectors, coupled with finely focused x-rays, have been used to study structure and dynamics of supersonic fuel sprays with 50 μm-spatial resolution and μs-temporal resolution in the region close to an injection nozzle

  2. A novel camera type for very high energy gamma-ray astronomy based on Geiger-mode avalanche photodiodes

    International Nuclear Information System (INIS)

    Anderhub, H; Biland, A; Boller, A; Braun, I; Commichau, S; Commichau, V; Dorner, D; Gendotti, A; Grimm, O; Gunten, H von; Hildebrand, D; Horisberger, U; Kraehenbuehl, T; Kranich, D; Lorenz, E; Lustermann, W; Backes, M; Neise, D; Bretz, T; Mannheim, K

    2009-01-01

    Geiger-mode avalanche photodiodes (G-APD) are promising new sensors for light detection in atmospheric Cherenkov telescopes. In this paper, the design and commissioning of a 36-pixel G-APD prototype camera is presented. The data acquisition is based on the Domino Ring Sampling (DRS2) chip. A sub-nanosecond time resolution has been achieved. Cosmic-ray induced air showers have been recorded using an imaging mirror setup, in a self-triggered mode. This is the first time that such measurements have been carried out with a complete G-APD camera.

  3. Towards sustainable vegetable production around agro-pastoral dams in Northern Benin

    NARCIS (Netherlands)

    Kpéra, G.N.; Segnon, Alcade C.; Saïdou, Aliou; Mensah, Guy A.; Aarts, Noelle; Zijpp, van der Akke J.

    2017-01-01

    Background: Rehabilitation and optimized utilization of agro-pastoral dams (APDs), especially for vegetable production, has been recently promoted to boost agricultural production and ensure food security in Benin. However, little information was available on APDs' agricultural potentials and

  4. Application of a three-microneedle device for the delivery of local anesthetics

    Directory of Open Access Journals (Sweden)

    Ishikawa K

    2015-04-01

    Full Text Available Kayoko Ishikawa,1 Hidekazu Fukamizu,1 Tetsuya Takiguchi,1 Yusuke Ohta,1 Yoshiki Tokura2 1Department of Plastic and Reconstructive Surgery, Hamamatsu University School of Medicine, Hamamatsu, Japan; 2Department of Dermatology, Hamamatsu University School of Medicine, Hamamatsu, Japan Purpose: We investigated the effectiveness of a newly developed device for the delivery of local anesthetics in the treatment of axillary osmidrosis and hyperhidrosis. We developed a device with three fine, stainless steel needles fabricated with a bevel angle facing outside (“three-microneedle device” [TMD] to release a drug broadly and homogeneously into tissue in the horizontal plane. Use of this device could reduce the risk of complications when transcutaneous injections are undertaken.Patients and methods: Sixteen Japanese patients were enrolled. The mean volume of lidocaine hydrochloride per unit area needed to elicit anesthesia when using a TMD was compared with that the volume required when using a conventional 27-gauge needle. The visual analog scale (VAS score of needlestick pain and injection-associated pain was also compared.Results: The mean volume of lidocaine hydrochloride per unit area to elicit anesthesia using the TMD was significantly lower than that the volume required when using the conventional 27-gauge needle. The VAS score of needlestick pain for the TMD was significantly lower than that the VAS score for the 27-gauge needle.Conclusion: These data suggest that the TMD could be useful for the delivery of local anesthetics in terms of clinical efficacy and avoidance of adverse effects. Keywords: three-microneedle device, transcutaneous drug delivery, local anesthesia, lidocaine, pain

  5. Group schema therapy versus group cognitive behavioral therapy for social anxiety disorder with comorbid avoidant personality disorder : Study protocol for a randomized controlled trial

    NARCIS (Netherlands)

    Baljé, A.; Greeven, A.; van Giezen, A.; Korrelboom, C.W.; Arntz, A.; Spinhoven, P.

    2016-01-01

    Background Social anxiety disorder (SAD) with comorbid avoidant personality disorder (APD) has a high prevalence and is associated with serious psychosocial problems and high societal costs. When patients suffer from both SAD and APD, the Dutch multidisciplinary guidelines for personality disorders

  6. Group schema therapy versus group cognitive behavioral therapy for social anxiety disorder with comorbid avoidant personality disorder : Study protocol for a randomized controlled trial

    NARCIS (Netherlands)

    Baljé, A.; Greeven, A.; van Giezen, A.; Korrelboom, K.; Arntz, A.; Spinhoven, P.

    2016-01-01

    BACKGROUND: Social anxiety disorder (SAD) with comorbid avoidant personality disorder (APD) has a high prevalence and is associated with serious psychosocial problems and high societal costs. When patients suffer from both SAD and APD, the Dutch multidisciplinary guidelines for personality disorders

  7. NASA Program Office Technology Investments to Enable Future Missions

    Science.gov (United States)

    Thronson, Harley; Pham, Thai; Ganel, Opher

    2018-01-01

    The Cosmic Origins (COR) and Physics of the Cosmos (PCOS) Program Offices (POs) reside at NASA GSFC and implement priorities for the NASA HQ Astrophysics Division (APD). One major aspect of the POs’ activities is managing our Strategic Astrophysics Technology (SAT) program to mature technologies for future strategic missions. The Programs follow APD guidance on which missions are strategic, currently informed by the NRC’s 2010 Decadal Survey report, as well as APD’s Implementation Plan and the Astrophysics Roadmap.In preparation for the upcoming 2020 Decadal Survey, the APD has established Science and Technology Definition Teams (STDTs) to study four large-mission concepts: the Origins Space Telescope (née, Far-IR Surveyor), Habitable Exoplanet Imaging Mission, Large UV/Optical/IR Surveyor, and Lynx (née, X-ray Surveyor). The STDTs will develop the science case and design reference mission, assess technology development needs, and estimate the cost of their concept. A fifth team, the L3 Study Team (L3ST), was charged to study potential US contributions to ESA’s planned Laser Interferometer Space Antenna (LISA) gravitational-wave observatory.The POs use a rigorous and transparent process to solicit technology gaps from the scientific and technical communities, and prioritize those entries based on strategic alignment, expected impact, cross-cutting applicability, and urgency. For the past two years, the technology-gap assessments of the four STDTs and the L3ST are included in our process. Until a study team submits its final report, community-proposed changes to gaps submitted or adopted by a study team are forwarded to that study team for consideration.We discuss our technology development process, with strategic prioritization informing calls for SAT proposals and informing investment decisions. We also present results of the 2017 technology gap prioritization and showcase our current portfolio of technology development projects. To date, 96 COR and 86

  8. Investigation of Avalanche Photodiodes Radiation Hardness for Baryonic Matter Studies

    Czech Academy of Sciences Publication Activity Database

    Kushpil, Vasilij; Mikhaylov, Vasily; Ladygin, V.; Kugler, Andrej; Kushpil, Svetlana; Svoboda, Ondřej; Tlustý, Pavel

    2016-01-01

    Roč. 13, č. 1 (2016), s. 120-126 ISSN 1547-4771 R&D Projects: GA MŠk LG12007; GA MŠk LG14004; GA MŠk(CZ) LM2011019 Institutional support: RVO:61389005 Keywords : APDs * detectors * neutrons Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders

  9. Acute alteration of cardiac ECG, action potential, I{sub Kr} and the human ether-a-go-go-related gene (hERG) K{sup +} channel by PCB 126 and PCB 77

    Energy Technology Data Exchange (ETDEWEB)

    Park, Mi-Hyeong; Park, Won Sun; Jo, Su-Hyun, E-mail: suhyunjo@kangwon.ac.kr

    2012-07-01

    Polychlorinated biphenyls (PCBs) have been known as serious persistent organic pollutants (POPs), causing developmental delays and motor dysfunction. We have investigated the effects of two PCB congeners, 3,3′,4,4′-tetrachlorobiphenyl (PCB 77) and 3,3′,4,4′,5-pentachlorobiphenyl (PCB 126) on ECG, action potential, and the rapidly activating delayed rectifier K{sup +} current (I{sub Kr}) of guinea pigs' hearts, and hERG K{sup +} current expressed in Xenopus oocytes. PCB 126 shortened the corrected QT interval (QTc) of ECG and decreased the action potential duration at 90% (APD{sub 90}), and 50% of repolarization (APD{sub 50}) (P < 0.05) without changing the action potential duration at 20% (APD{sub 20}). PCB 77 decreased APD{sub 20} (P < 0.05) without affecting QTc, APD{sub 90}, and APD{sub 50}. The PCB 126 increased the I{sub Kr} in guinea-pig ventricular myocytes held at 36 °C and hERG K{sup +} current amplitude at the end of the voltage steps in voltage-dependent mode (P < 0.05); however, PCB 77 did not change the hERG K{sup +} current amplitude. The PCB 77 increased the diastolic Ca{sup 2+} and decreased Ca{sup 2+} transient amplitude (P < 0.05), however PCB 126 did not change. The results suggest that PCB 126 shortened the QTc and decreased the APD{sub 90} possibly by increasing I{sub Kr}, while PCB 77 decreased the APD{sub 20} possibly by other modulation related with intracellular Ca{sup 2+}. The present data indicate that the environmental toxicants, PCBs, can acutely affect cardiac electrophysiology including ECG, action potential, intracellular Ca{sup 2+}, and channel activity, resulting in toxic effects on the cardiac function in view of the possible accumulation of the PCBs in human body. -- Highlights: ► PCBs are known as serious environmental pollutants and developmental disruptors. ► PCB 126 shortened QT interval of ECG and action potential duration. ► PCB 126 increased human ether-a-go-go-related K{sup +} current and I{sub Kr}.

  10. A 500-MHz x-ray counting system with a silicon avalanche photodiode

    International Nuclear Information System (INIS)

    Kishimoto, Shunji

    2009-01-01

    In the present measurements using a Si-APD X-ray detector and a 500-MHz counting system, the maximum output rate of 3.3x10 8 s -1 was achieved for 8-keV X-rays in beamline BL-14A of the Photon Factory. A small Si-APD of 4-pF electric capacity was used as the detector device in order to output a pulse of a width shorter than 2 ns on the baseline. For processing the fast pulses, the discriminator and the scaler having a throughput of >500 MHz, were prepared. Since the acceleration frequency at the PF ring was 500.1 MHz and the empty-bunch spacing was 12/312 bunches per circumference, the expected maximum rate was 4.8x10 8s-1 according to the counting model for a pulsed photon source. The reason why the present system did not reach the expected value was the baseline shift at the amplifier outputs. The rise of +0.2 V was observed at a discriminator output of 3.3x10 8 s -1 , while the pulse height was lower than 0.2 V. The baseline shift was caused by an AC coupling circuit in the amplifier. If a DC coupling circuit can be used for the amplifier, instead of the AC coupling circuit, or an active adjustment to compensate the baseline shift is installed, the counting system will show an ideal response. Although the present system including NIM modules was not so compact, we would like to develop a new fast-counting circuit for a Si-APD array detector of more than 100 channels of small pixels, in near future. (author)

  11. A retrospective cohort study on the association between periapical abscess, advanced periodontal disease, and the national oral health screening program among Korean adults.

    Science.gov (United States)

    Ha, Jung-Eun; Jung, Se-Hwan; Jin, Bo-Hyoung; Lee, Byoung-Jin; Bae, Kwang-Hak

    2013-09-01

    The National Oral Health Screening Program (NOHSP) is a general population-based program in Korea. The objective of this study was to assess the association between participation in the NOHSP and dental visit for periapical abscess (PA) and advanced periodontal disease (APD) among Korean adults. Data were obtained for subjects from the National Health Insurance database. The authors conducted a retrospective cohort study of 9358 randomly selected subjects who were between 40 and 64 years old in 2002. The outcomes of dental visit for PA or APD from the years 2003 to 2007 were compared between the screening and nonscreening groups. The nonscreening group had 19% higher risk of PA and 15% higher risk of APD. This study suggests that the NOHSP may decrease the risk of dental visit because of PA and APD by preventing the progress of lesion to the advanced stage among Korean adults.

  12. A low-noise, wideband, integrated CMOS transimpedance preamplifier for photodiode applications

    International Nuclear Information System (INIS)

    Binkley, D.M.; Paulus, M.J.; Casey, M.E.; Rochelle, J.M.

    1992-01-01

    In this paper, a low-noise, wideband, integrated CMOS transimpedance preamplifier is presented for silicon avalanche photodiode (APD) applications. The preamplifier, fabricated in a standard 2μ CMOS technology, features a transimpedance gain of 45 kΩ, a risetime of 22 ns, a series noise of 1.6nV/Hz 1/2 , and a wideband equivalent input-noise current of 12 nA for a source capacitance of 12 pF. The measured 22 Na timing resolution of 9.2-ns FWHM and energy resolution of 22.4% FWHM for the RCA C30994 BGO/APD detector module coupled to the preamplifier is comparable to the performance reported using charge-sensitive preamplifiers. This illustrates that transimpedance preamplifiers should be considered for APD applications, especially where APD noise current dominates noise from feedback resistors in the 1--kΩ to 50-kΩ range

  13. Qualidade de Vida: comparação entre diálise peritoneal automatizada e hemodiálise Calidad de vida: comparación entre diálisis peritoneal automatizada y hemodiálisis Quality of Life: comparison between patients on automated peritoneal dialysis and patients on hemodialysis

    Directory of Open Access Journals (Sweden)

    Valquiria Greco Arenas

    2009-01-01

    Full Text Available OBJETIVO: Avaliar a Qualidade de Vida relacionada à saúde em pacientes submetidos à Diálise Peritoneal Automatizada (DPA e Hemodiálise em um centro de diálise satélite no Município de São Paulo. MÉTODOS: Este estudo observacional transversal, incluiu 101 pacientes com idade entre 18-75 anos, em terapia há mais de 90 dias e que compreenderam o questionário. RESULTADOS: O grupo em Hemodiálise (n=79 estava em terapia há mais tempo (p=0.001 e tinha albumina sérica maior (pOBJETIVO: Evaluar la Calidad de Vida relacionada a la salud de pacientes sometidos a Diálisis Peritoneal Automatizada (DPA y Hemodiálisis en un centro de diálisis del Municipio de Sao Paulo. MÉTODOS: Este estudio observacional transversal, incluyó a 101 pacientes con edades comprendidas entre los 18 y 75 años, que se encontraban en terapia hace más de 90 días y que comprendieran el cuestionario. RESULTADOS: El grupo en Hemodiálisis (n=79 estaba en terapia hace más de un tiempo (p=0.001 y tenía albúmina sérica mayor (pOBJECTIVE: To evaluate the health-related quality of life in patients from a satellite dialysis center in São Paulo city undergoing Automated Peritoneal Dialysis (APD or Hemodialysis. METHODS: This cross-sectional descriptive study included 101 patients with ages ranging from 18 to 75 years-old, who were in dialysis treatment over 90 days and able to understand the items of the SF-36 questionnaire in Portuguese. RESULTS: The Hemodialysis group (n=79 had been in dialysis treatment longer (p=0.001 and had higher serum albumin level (p<0.001 than the APD group (n=22. The SF-36 scores of the two groups were similar in all dimensions, except for the physical functioning dimension, on which the hemodialysis group had higher scores than the APD group (p=0.03. There were no statistically significant interactions between the SF-36 score and the other variables of the study. CONCLUSION: There were no differences in quality of life between patients on

  14. Hypothermia following antipsychotic drug use

    NARCIS (Netherlands)

    Marum, R.J. van; Wegewijs, M.A.; Loonen, A.J.M.; Beers, E.

    2007-01-01

    Objective: Hypothermia is an adverse drug reaction (ADR) of antipsychotic drug (APD) use. Risk factors for hypothermia in ADP users are unknown. We studied which risk factors for hypothermia can be identified based on case reports. Method: Case reports of hypothermia in APD-users found

  15. Personality functioning in patients with avoidant personality disorder and social phobia

    NARCIS (Netherlands)

    Eikenaes, I.; Hummelen, B.; Abrahamsen, G.; Andrea, H.; Wilberg, T.

    2013-01-01

    Avoidant personality disorder (APD) and social phobia (SP) are closely related, such that they are suggested to represent different severity levels of one social anxiety disorder. This cross-sectional study aimed to compare patients with APD to patients with SP, with particular focus on personality

  16. High precision, low disturbance calibration of the High Voltage system of the CMS Barrel Electromagnetic Calorimeter

    CERN Document Server

    Fasanella, Giuseppe

    2017-01-01

    The CMS Electromagnetic Calorimeter utilizes scintillating lead tungstate crystals, with avalanche photodiodes (APD) as photo-detectors in the barrel part. 1224 HV channels bias groups of 50 APD pairs, each at a voltage of about 380 V. The APD gain dependence on the voltage is 3pct/V. A stability of better than 60 mV is needed to have negligible impact on the calorimeter energy resolution. Until 2015 manual calibrations were performed yearly. A new calibration system was deployed recently, which satisfies the requirement of low disturbance and high precision. The system is discussed in detail and first operational experience is presented.

  17. High precision, low disturbance calibration of the High Voltage system of the CMS Barrel Electromagnetic Calorimeter

    CERN Document Server

    Fasanella, Giuseppe

    2016-01-01

    The CMS Electromagnetic Calorimeter utilizes scintillating lead tungstate crystals, with avalanche photodiodes (APD) as photo-detectors in the barrel part. 1224 HV channels bias groups of 50 APD pairs, each at a voltage of about 380 V. The APD gain dependence on the voltage is 3pct/V. A stability of better than 60 mV is needed to have negligible impact on the calorimeter energy resolution. Until 2015 manual calibrations were performed yearly. A new calibration system was deployed recently, which satisfies the requirement of low disturbance and high precision. The system is discussed in detail and first operational experience is presented.

  18. Performance Analysis of Spectral Amplitude Coding Based OCDMA System with Gain and Splitter Mismatch

    Science.gov (United States)

    Umrani, Fahim A.; Umrani, A. Waheed; Umrani, Naveed A.; Memon, Kehkashan A.; Kalwar, Imtiaz Hussain

    2013-09-01

    This paper presents the practical analysis of the optical code-division multiple-access (O-CDMA) systems based on perfect difference codes. The work carried out use SNR criterion to select the optimal value of avalanche photodiodes (APD) gain and shows how the mismatch in the splitters and gains of the APD used in the transmitters and receivers of network can degrade the BER performance of the system. The investigations also reveal that higher APD gains are not suitable for such systems even at higher powers. The system performance, with consideration of shot noise, thermal noise, bulk and surface leakage currents is also investigated.

  19. Update on Linear Mode Photon Counting with the HgCdTe Linear Mode Avalanche Photodiode

    Science.gov (United States)

    Beck, Jeffrey D.; Kinch, Mike; Sun, Xiaoli

    2014-01-01

    The behavior of the gain-voltage characteristic of the mid-wavelength infrared cutoff HgCdTe linear mode avalanche photodiode (e-APD) is discussed both experimentally and theoretically as a function of the width of the multiplication region. Data are shown that demonstrate a strong dependence of the gain at a given bias voltage on the width of the n- gain region. Geometrical and fundamental theoretical models are examined to explain this behavior. The geometrical model takes into account the gain-dependent optical fill factor of the cylindrical APD. The theoretical model is based on the ballistic ionization model being developed for the HgCdTe APD. It is concluded that the fundamental theoretical explanation is the dominant effect. A model is developed that combines both the geometrical and fundamental effects. The model also takes into account the effect of the varying multiplication width in the low bias region of the gain-voltage curve. It is concluded that the lower than expected gain seen in the first 2 × 8 HgCdTe linear mode photon counting APD arrays, and higher excess noise factor, was very likely due to the larger than typical multiplication region length in the photon counting APD pixel design. The implications of these effects on device photon counting performance are discussed.

  20. Electrophysiological changes of Papillary Muscles in Guinea Pigs with iron deficiency anemia and heart failure

    Directory of Open Access Journals (Sweden)

    Ling Fan1

    2017-04-01

    Full Text Available Objective: To investigate the changes of left ventricular papillary muscle action potentials in guinea pigs with iron deficiency anemia and heart failure. Methods: A total of 20 cases of iron deficiency anemia with heart failure were treated with experimental group and 10 normal guinea pigs as control group. Blood samples were collected to determine hemoglobin content, red blood cell number and whole blood iron index, and the changes of cardiac function and hemodynamics were detected by 6 240 biological signal collection system to determine whether the model was successful or not, Intracellular microelectrode technique was used to determine the action potentials of the papillary muscles in the model group and the control group. the potential amplitudes (APA, overshoot values (APA, maximum depolarization rate (Vmax, 20 % of repolarization, 50 % and 90 % of repolarization (APD20, APD50 and APD90 and the average velocity of repolarization were measured. Compare statistical difference between the model group and the control group. Results: 14 cases of model group survived completely, compared with control group, APD50 and APD90 prolonged, and the average velocity decreased. Conclusions: the action potential repolarization duration in the guinea pig papillary muscle of iron deficiency anemia with heart failure is prolonged, and the average repolarization velocity is slow.

  1. [Effects of synthetic antioxidant ionol on bioelectric activity of cardiomyocytes and arrhythmia in global ischemia and reperfusion of the isolated rat heart].

    Science.gov (United States)

    Belkina, L M; Vovk, V I; Meerson, F Z

    1992-04-01

    Isolated rat hearts were subjected to global ischemia (15 min) and reperfusion (20 min). Transmembrane potentials were recorded on the epicardial surface and contractile force was measured. Ischemia reduced the resting potential, the action potential (AP) amplitude and the AP duration (APD) in control animals. Pretreatment with synthetic antioxidant ionol (BHT, 50 mg/kg, per os) didn't influence the time course of changes in the resting potential and AP amplitude during ischemia, but significantly increased APD. In the pretreated group, 5 min after the aorta clamping, the APD at 50% and 90% levels of repolarization was 36% (p less than 0.05) and 13% (p less than 0.1) higher in comparison to the preischemic level and 10 min after clamping by 27% (p less than 0.1) and 29% (p less than 0.05), respectively. By the end of ischemia in the pretreated group, APD re-decreased almost to basal level, but in control group, it remained decreased. During reperfusion BHT improved the recovery of bioelectrical activity and the contractile function. The BHT 10-fold reduced the malignant arrhythmias duration and 2.5-fold the incidence of ventricular tachycardia and fibrillation during reperfusion. These results indicate that the induced by BHT increase in APD can contribute to the mechanism of BHT antiarrhythmic action.

  2. Differential effects of psychopathy and antisocial personality disorder symptoms on cognitive and fear processing in female offenders

    Science.gov (United States)

    Anton, Marja E.; Vitale, Jennifer E.; Curtin, John J.; Newman, Joseph P.

    2012-01-01

    Psychopathy and antisocial personality disorder (APD) have long been considered important risk factors for criminal behavior and incarceration. However, little is known about the psychobiological underpinnings that give rise to the disinhibited behavior of female offenders. Using an instructed fear-conditioning paradigm and a sample of incarcerated female offenders, we manipulated attentional focus and cognitive load to characterize and differentiate between the dysfunctional cognitive and affective processes associated with these syndromes. We used fear-potentiated startle (FPS) and event-related potentials as measures of affective and cognitive processing, respectively. After controlling for APD symptoms, psychopathic women displayed greater FPS while attending directly to threat-relevant stimuli and displayed less FPS while performing a demanding task that directed attention to threat-irrelevant information. Conversely, controlling for psychopathy, women with high APD symptoms displayed less overall FPS, especially when instructed to focus on threat-relevant stimuli. However, as the demands on cognitive resources increased, they displayed greater FPS. For both psychopathy and APD, analysis of the event-related potentials qualified these findings and further specified the abnormal cognitive processes associated with these two syndromes. Overall, simultaneous analysis of psychopathy and APD revealed distinct patterns of cognitive processing and fear reactivity. PMID:22886692

  3. CT-1-CP-induced ventricular electrical remodeling in mice.

    Science.gov (United States)

    Chen, Shu-fen; Wei, Tao-zhi; Rao, Li-ya; Xu, Ming-guang; Dong, Zhan-ling

    2015-02-01

    The chronic effects of carboxyl-terminal polypeptide of Cardiotrophin-1 (CT-1-CP) on ventricular electrical remodeling were investigated. CT-1-CP, which contains 16 amino acids in sequence of the C-terminal of Cardiotrophin-1, was selected and synthesized, and then administered to Kunming mice (aged 5 weeks) by intraperitoneal injection (500 ng·g⁻¹·day⁻¹) (4 groups, n=10 and female: male=1:1 in each group) for 1, 2, 3 and 4 weeks, respectively. The control group (n=10, female: male=1:1) was injected by physiological saline for 4 weeks. The epicardial monophasic action potential (MAP) was recorded by using a contact-type MAP electrode placed vertically on the left ventricular (LV) epicardium surface, and the electrocardiogram (ECG) signal in lead II was monitored synchronously. ECG intervals (RR, PR, QRS and QT) and the amplitude of MAP (Am), the maximum upstroke velocity (Vmax), as well as action potential durations (APDs) at different repolarization levels (APD30, APD50, APD70, and APD90) of MAP were determined and analyzed in detail. There were no significant differences in RR and P intervals between CT-1-CP-treated groups and control group, but the PR segment and the QRS complex were greater in the former than in the latter (F=2.681 and 5.462 respectively, PCP-treated groups than in control group, the QT dispersion (QTd) of them was greater in the latter than in the former (F=3.090, PCP-treated groups and the prolongation of QT intervals increased gradually along with the time of exposure to CT-1-CP. The QRS complex had no significant change in control group, one-week and three-week CT-1-CP-treated groups, but prolonged significantly in two-week and four-week CT-1-CP-treated groups. Interestingly, the QTd after chest-opening was significantly greater than that before chest-opening in control group (t=5.242, PCP-treated groups. The mean MAP amplitude, Vmax and APD were greater in CT-1-CP-treated groups than those in control group, and became more obvious

  4. Peeling the Onion of Auditory Processing Disorder: A Language/Curricular-Based Perspective

    Science.gov (United States)

    Wallach, Geraldine P.

    2011-01-01

    Purpose: This article addresses auditory processing disorder (APD) from a language-based perspective. The author asks speech-language pathologists to evaluate the functionality (or not) of APD as a diagnostic category for children and adolescents with language-learning and academic difficulties. Suggestions are offered from a…

  5. Evidence-based interventions of dichotic listening training, compensatory strategies and combined therapies in managing pupils with auditory processing disorders.

    Science.gov (United States)

    Osisanya, Ayo; Adewunmi, Abiodun T

    2018-02-01

    The need to develop a measure of managing children with a single profile of auditory processing disorders (APDs), and differentiate between true and artefactual improvements necessitated the study. The study also sought to determine the efficacy of interventions - both single and combined on APD, against no-treatment. A randomised controlled trial of interventions (RCT) was adopted. Participants were randomly allocated to each of the intervention groups or the no intervention group. The 10 weeks intervention included 45 minutes three times a week therapeutic intervention on listening with noise and sound localisation ability in the home and school environments. 80 pupils (7-11 years) with a single profile of APD participated in the study. Treatments were effective on the cocktail party and sound localisation. The best result was realised with the combined therapy (CT), and there was no significant difference in performance in the remaining treatment groups. The intervention groups were beneficial to pupils with APD and should be adopted by clinicians.

  6. Affective instability as a clinical feature of avoidant personality disorder.

    Science.gov (United States)

    Snir, Avigal; Bar-Kalifa, Eran; Berenson, Kathy R; Downey, Geraldine; Rafaeli, Eshkol

    2017-10-01

    The current study's main goal was to examine whether affective instability is elevated among individuals suffering from avoidant personality disorder (APD) by comparing it to the affective instability found among individuals suffering from borderline personality disorder (BPD) as well that found among healthy controls. Adults (N = 152, aged 18-65 years) with BPD, APD, or no psychopathology participated in a 3-week computerized diary study. We examined temporal instability in negative affect using experience-sampling methods. Both within and between days, individuals with APD showed greater affective instability compared to the healthy control individuals, although less affective instability compared to individuals with BPD. The findings are in line with affective instability (or emotional lability) as a key dimension relevant across personality disorders. Additionally, they emphasize the need for research and clinical attention to affective characteristics (alongside the more readily recognized interpersonal characteristics) of APD. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  7. Cognitive control deficits associated with antisocial personality disorder and psychopathy.

    Science.gov (United States)

    Zeier, Joshua D; Baskin-Sommers, Arielle R; Hiatt Racer, Kristina D; Newman, Joseph P

    2012-07-01

    Antisociality has been linked to a variety of executive functioning deficits, including poor cognitive control. Surprisingly, cognitive control deficits are rarely found in psychopathic individuals, despite their notoriously severe and persistent antisocial behavior. In fact, primary (low-anxious) psychopathic individuals display superior performance on cognitive control-type tasks under certain circumstances. To clarify these seemingly contradictory findings, we administered a response competition (i.e., flanker) task to incarcerated offenders, who were assessed for Antisocial Personality Disorder (APD) symptoms and psychopathy. As hypothesized, APD related to poorer accuracy, especially on incongruent trials. Contrary to expectation, however, the same pattern of results was found in psychopathy. Additional analyses indicated that these effects of APD and psychopathy were associated with overlapping variance. The findings suggest that psychopathy and APD symptoms are both associated with deficits in cognitive control, and that this deficit relates to general antisociality as opposed to a specific antisocial syndrome. PsycINFO Database Record (c) 2012 APA, all rights reserved.

  8. An improved design for AlGaN solar-blind avalanche photodiodes with enhanced avalanche ionization

    International Nuclear Information System (INIS)

    Tang Yin; Cai Qing; Chen Dun-Jun; Lu Hai; Zhang Rong; Zheng You-Dou; Yang Lian-Hong; Dong Ke-Xiu

    2017-01-01

    To enhance the avalanche ionization, we designed a new separate absorption and multiplication AlGaN solar-blind avalanche photodiode (APD) by using a high/low-Al-content AlGaN heterostructure as the multiplication region instead of the conventional AlGaN homogeneous layer. The calculated results show that the designed APD with Al 0.3 Ga 0.7 N/Al 0.45 Ga 0.55 N heterostructure multiplication region exhibits a 60% higher gain than the conventional APD and a smaller avalanche breakdown voltage due to the use of the low-Al-content Al 0.3 Ga 0.7 N which has about a six times higher hole ionization coefficient than the high-Al-content Al 0.45 Ga 0.55 N. Meanwhile, the designed APD still remains a good solar-blind characteristic by introducing a quarter-wave AlGaN/AlN distributed Bragg reflectors structure at the bottom of the device. (paper)

  9. Determination of the excess noise of avalanche photodiodes integrated in 0.35-μm CMOS technologies

    Science.gov (United States)

    Jukić, Tomislav; Brandl, Paul; Zimmermann, Horst

    2018-04-01

    The excess noise of avalanche photodiodes (APDs) integrated in a high-voltage (HV) CMOS process and in a pin-photodiode CMOS process, both with 0.35-μm structure sizes, is described. A precise excess noise measurement technique is applied using a laser source, a spectrum analyzer, a voltage source, a current meter, a cheap transimpedance amplifier, and a personal computer with a MATLAB program. In addition, usage for on-wafer measurements is demonstrated. The measurement technique is verified with a low excess noise APD as a reference device with known ratio k = 0.01 of the impact ionization coefficients. The k-factor of an APD developed in HV CMOS is determined more accurately than known before. In addition, it is shown that the excess noise of the pin-photodiode CMOS APD depends on the optical power for avalanche gains above 35 and that modulation doping can suppress this power dependence. Modulation doping, however, increases the excess noise.

  10. The active personnel dosimeter---APFEL enterprises superheated drop detector

    International Nuclear Information System (INIS)

    Ipe, N.E.; Donahue, R.J.; Busick, D.D.

    1991-03-01

    The Active Personnel Dosimeter (APD) provides a digital readout of events caused by neutrons interacting with superheated liquid droplets. The droplets are suspended in a gel held in a replaceable cartridge. Upon neutron interaction, the superheated droplet vaporizes, forming a bubble. The sound produced in this process is recorded by transducers that sense the accompanying pressure pulse. The APD electronically discriminates against spurious noise and vibration. Studies with the production prototype APDs indicate that the detector response is linear up to about 0.40 mSv, with large variations sometimes from predicted values and between cartridges at higher dose equivalents. The response to standard neutron sources (bare 252 Cf, PuBe, PuB, PuF, PuLi) is reported and compared with the expected response. Unirradiated cartridges self-nucleate when heated to temperatures of 46 degrees C. The APD is insensitive to low-energy photons but responds to high-energy photons and electrons. 8 refs., 2 figs., 3 tabs

  11. On the efficiency of photon emission during electrical breakdown in silicon

    International Nuclear Information System (INIS)

    Nepomuk Otte, A.

    2009-01-01

    This paper presents a study of photons that are emitted during electrical breakdown in p-n silicon diodes. The method that was developed for this study uses the optical-crosstalk effect that is observed in Geigermode-APD (G-APD) photon detectors. The outcome of this study is twofold: firstly, mainly photons with energies between 1.15 and 1.4 eV contribute to the optical crosstalk in G-APDs used in this study. This observation is explained by the strong energy dependence of the absorption length of photons in silicon. Secondly, the intensity with which photons with energies between 1.15 and 1.4 eV are emitted during a breakdown is 3x10 -5 photons per charge carrier in the breakdown region. The uncertainty of the intensity is estimated to be a factor of two. For this study a simulation package Siliconphotomultiplier Simulator (SiSi) was developed, which can be used to address various other questions that arise in the application of G-APDs.

  12. Multivariate dependencies between difficult childhood, temperament and antisocial personality disorder in a population of French male prisoners.

    Science.gov (United States)

    Pousset, M; Tremblay, R E; Falissard, B

    2011-06-01

    The aim of this study was to contribute to clarification of the relations between antisocial personality disorder (APD) and its potential risk factors in a population of 560 French male prisoners. Adverse childhood was assessed as a latent variable determined by several traumatic events. APD (MINI), character and temperament (Cloninger's model), WAIS®-III similarities subtest and psychosocial characteristics were assessed by two clinicians. The WAIS®-III subtest accounts for verbal and cognitive performance. We used a structural model to determine the weight of the different pathways between adverse childhood and APD. Study confirmed the major and direct role of adverse childhood (standardized coefficient=0.48). An intermediate effect mediated by character (considered as a global variable) and novelty-seeking was also shown, confirming previous results from the literature. This study emphasizes the role of adverse childhood in APD, suggesting the potential benefit of early intervention in the prevention of antisocial behaviours. Copyright © 2011. Published by Elsevier Masson SAS.

  13. Microelectrode array measurement of potassium ion channel remodeling on the field action potential duration in rapid atrial pacing rabbits model.

    Science.gov (United States)

    Sun, Juan; Yan, Huang; Wugeti, Najina; Guo, Yujun; Zhang, Ling; Ma, Mei; Guo, Xingui; Jiao, Changan; Xu, Wenli; Li, Tianqi

    2015-01-01

    Atrial fibrillation (AF) arises from abnormalities in atrial structure and electrical activity. Microelectrode arrays (MEA) is a real-time, nondestructive measurement of the resting and action potential signal, from myocardial cells, to the peripheral circuit of electrophysiological activity. This study examined the field action potential duration (fAPD) of the right atrial appendage (RAA) by MEA in rapid atrial pacing (RAP) in the right atrium of rabbits. In addition, this study also investigated the effect of potassium ion channel blockers on fAPD. 40 New Zealand white rabbits of either sex were randomly divided into 3 groups: 1) the control, 2) potassium ion channel blocker (TEA, 4-Ap and BaCl2), and 3) amiodarone groups. The hearts were quickly removed and right atrial appendage sectioned (slice thickness 500 μm). Each slice was perfused with Tyrode's solution and continuously stimulated for 30 minutes. Sections from the control group were superfused with Tyrode's solution for 10 minutes, while the blocker groups and amiodarone were both treated with their respective compounds for 10 minutes each. The fAPD of RAA and action field action potential morphology were measured using MEA. In non-pace (control) groups, fAPD was 188.33 ± 18.29 ms after Tyrode's solution superfusion, and 173.91 ± 6.83 ms after RAP. In pace/potassium ion channel groups, TEA and BaCl2 superfusion prolonged atrial field action potential (fAPD) (control vs blocker: 176.67 ± 8.66 ms vs 196.11 ± 10.76 ms, 182.22 ± 12.87 ms vs 191.11 ± 13.09 ms with TEA and BaCl2 superfusion, respectively, P action potential in animal heart slices. After superfusing potassium ion channel blockers, fAPD was prolonged. These results suggest that Ito, IKur and IK1 remodel and mediate RAP-induced atrial electrical remodeling. Amiodarone alter potassium ion channel activity (Ito, IKur, IK1 and IKs), shortening fAPD.

  14. Hypothermia following antipsychotic drug use

    NARCIS (Netherlands)

    van Marum, Rob J.; Wegewijs, Michelle A.; Loonen, Anton J. M.; Beers, Erna

    Objective Hypothermia is an adverse drug reaction (ADR) of antipsychotic drug (APD) use. Risk factors for hypothermia in ADP users are unknown. We studied which risk factors for hypothermia can be identified based on case reports. Methods Case reports of hypothermia in APD-users found in PUBMED or

  15. Comorbidity of Auditory Processing, Language, and Reading Disorders

    Science.gov (United States)

    Sharma, Mridula; Purdy, Suzanne C.; Kelly, Andrea S.

    2009-01-01

    Purpose: The authors assessed comorbidity of auditory processing disorder (APD), language impairment (LI), and reading disorder (RD) in school-age children. Method: Children (N = 68) with suspected APD and nonverbal IQ standard scores of 80 or more were assessed using auditory, language, reading, attention, and memory measures. Auditory processing…

  16. Short-Term Memory and Auditory Processing Disorders: Concurrent Validity and Clinical Diagnostic Markers

    Science.gov (United States)

    Maerlender, Arthur

    2010-01-01

    Auditory processing disorders (APDs) are of interest to educators and clinicians, as they impact school functioning. Little work has been completed to demonstrate how children with APDs perform on clinical tests. In a series of studies, standard clinical (psychometric) tests from the Wechsler Intelligence Scale for Children, Fourth Edition…

  17. Quality of life in automated and continuous ambulatory peritoneal dialysis

    NARCIS (Netherlands)

    Michels, Wieneke M.; van Dijk, Sandra; Verduijn, Marion; le Cessie, Saskia; Boeschoten, Elisabeth W.; Dekker, Friedo W.; Krediet, Raymond T.; Apperloo, A. J.; Bijlsma, J. A.; Boekhout, M.; Boer, W. H.; van der Boog, P. J. M.; Büller, H. R.; van Buren, M.; de Charro, F. Th; Doorenbos, C. J.; van den Dorpel, M. A.; van Es, A.; Fagel, W. J.; Feith, G. W.; de Fijter, C. W. H.; Frenken, L. A. M.; Grave, W.; van Geelen, J. A. C. A.; Gerlag, P. G. G.; Gorgels, J. P. M. C.; Huisman, R. M.; Jager, K. J.; Jie, K.; Koning-Mulder, W. A. H.; Koolen, M. I.; Kremer Hovinga, T. K.; Lavrijssen, A. T. J.; Luik, A. J.; van der Meulen, J.; Parlevliet, K. J.; Raasveld, M. H. M.; van der Sande, F. M.; Schonck, M. J. M.; Schuurmans, M. M. J.; Siegert, C. E. H.; Stegeman, C. A.; Stevens, P.; Thijssen, J. G. P.; Valentijn, R. M.; Vastenburg, G. H.; Verburgh, C. A.; Vincent, H. H.; Vos, P. F.

    2011-01-01

    Despite a lack of strong evidence, automated peritoneal dialysis (APD) is often prescribed on account of an expected better quality of life (QoL) than that expected with continuous ambulatory peritoneal dialysis (CAPD). Our aim was to analyze differences in QoL in patients starting dialysis on APD

  18. The outcome of antenatal ultrasound diagnosed anomalies of the kidney and urinary tract in a large Danish birth cohort

    DEFF Research Database (Denmark)

    Andrés-Jensen, Liv; Jørgensen, Finn Stener; Thorup, Jorgen

    2016-01-01

    cases. The greater the prenatal and postnatal APD, the higher risk of febrile urinary tract infection (fUTI) and surgical intervention, and lower probability of resolution. 25% of the identified patients had fUTI and/or surgery. CONCLUSIONS: We recommend threshold values of APD at least 10 mm...

  19. Relation of size of seminal vesicles on ultrasound to premature ejaculation

    Directory of Open Access Journals (Sweden)

    Zhi-Wei Hong

    2017-01-01

    Full Text Available Myriad biological factors have been proposed to explain premature ejaculation (PE. However, data correlating PE with seminal vesicles (SVs are sparse. The study aimed to evaluate the relationship between the size of SV and PE. The cross-sectional study included 44 outpatients with PE and 44 volunteers without PE, and the size of SV was compared. Self-estimated intravaginal ejaculatory latency time, the Premature Ejaculation Diagnostic Tool (PEDT, the International Index of Erectile Function-15, and the National Institutes of Health-Chronic Prostatitis Symptom Index were used for assessment of symptoms. Compared to the control group, the PE group had significantly higher mean anterior-posterior diameter (APD of SV (P < 0.001. The optimal mean APD of SV cutoff level was 9.25 mm for PE. In the PE group, PEDT was also higher with a mean APD of SV ≥9.25 mm compared with mean APD of SV <9.25 mm. PEDT was significantly correlated with the mean APD of SV (r = 0.326, P = 0.031. The seminal plasma proteins were compared between six PE and six matched control cases by mass spectrometry and it was shown that 102 proteins were at least 1.5-fold up- or down-regulated. Among them, GGT1, LAMC1, and APP were significantly higher in the PE group. These results indicated that men with a larger mean APD of SV might have a higher PEDT score. Transrectal ultrasound of SV should be considered in the evaluation of patients with premature ejaculation. SV might be a potential target for the treatment of patients with PE and ultrasound change in SV.

  20. The relation between working memory capacity and auditory lateralization in children with auditory processing disorders.

    Science.gov (United States)

    Moossavi, Abdollah; Mehrkian, Saiedeh; Lotfi, Yones; Faghihzadeh, Soghrat; sajedi, Hamed

    2014-11-01

    Auditory processing disorder (APD) describes a complex and heterogeneous disorder characterized by poor speech perception, especially in noisy environments. APD may be responsible for a range of sensory processing deficits associated with learning difficulties. There is no general consensus about the nature of APD and how the disorder should be assessed or managed. This study assessed the effect of cognition abilities (working memory capacity) on sound lateralization in children with auditory processing disorders, in order to determine how "auditory cognition" interacts with APD. The participants in this cross-sectional comparative study were 20 typically developing and 17 children with a diagnosed auditory processing disorder (9-11 years old). Sound lateralization abilities investigated using inter-aural time (ITD) differences and inter-aural intensity (IID) differences with two stimuli (high pass and low pass noise) in nine perceived positions. Working memory capacity was evaluated using the non-word repetition, and forward and backward digits span tasks. Linear regression was employed to measure the degree of association between working memory capacity and localization tests between the two groups. Children in the APD group had consistently lower scores than typically developing subjects in lateralization and working memory capacity measures. The results showed working memory capacity had significantly negative correlation with ITD errors especially with high pass noise stimulus but not with IID errors in APD children. The study highlights the impact of working memory capacity on auditory lateralization. The finding of this research indicates that the extent to which working memory influences auditory processing depend on the type of auditory processing and the nature of stimulus/listening situation. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  1. Effect of mental challenge induced by movie clips on action potential duration in normal human subjects independent of heart rate.

    Science.gov (United States)

    Child, Nicholas; Hanson, Ben; Bishop, Martin; Rinaldi, Christopher A; Bostock, Julian; Western, David; Cooklin, Michael; O'Neil, Mark; Wright, Matthew; Razavi, Reza; Gill, Jaswinder; Taggart, Peter

    2014-06-01

    Mental stress and emotion have long been associated with ventricular arrhythmias and sudden death in animal models and humans. The effect of mental challenge on ventricular action potential duration (APD) in conscious healthy humans has not been reported. Activation recovery intervals measured from unipolar electrograms as a surrogate for APD (n=19) were recorded from right and left ventricular endocardium during steady-state pacing, whilst subjects watched an emotionally charged film clip. To assess the possible modulating role of altered respiration on APD, the subjects then repeated the same breathing pattern they had during the stress, but without the movie clip. Hemodynamic parameters (mean, systolic, and diastolic blood pressure, and rate of pressure increase) and respiration rate increased during the stressful part of the film clip (P=0.001). APD decreased during the stressful parts of the film clip, for example, for global right ventricular activation recovery interval at end of film clip 193.8 ms (SD, 14) versus 198.0 ms (SD, 13) during the matched breathing control (end film left ventricle 199.8 ms [SD, 16] versus control 201.6 ms [SD, 15]; P=0.004). Respiration rate increased during the stressful part of the film clip (by 2 breaths per minute) and was well matched in the respective control period without any hemodynamic or activation recovery interval changes. Our results document for the first time direct recordings of the effect of a mental challenge protocol on ventricular APD in conscious humans. The effect of mental challenge on APD was not secondary to emotionally induced altered respiration or heart rate. © 2014 American Heart Association, Inc.

  2. An Acoustic Charge Transport Imager for High Definition Television Applications: Reliability Modeling and Parametric Yield Prediction of GaAs Multiple Quantum Well Avalanche Photodiodes. Degree awarded Oct. 1997

    Science.gov (United States)

    Hunt, W. D.; Brennan, K. F.; Summers, C. J.; Yun, Ilgu

    1994-01-01

    Reliability modeling and parametric yield prediction of GaAs/AlGaAs multiple quantum well (MQW) avalanche photodiodes (APDs), which are of interest as an ultra-low noise image capture mechanism for high definition systems, have been investigated. First, the effect of various doping methods on the reliability of GaAs/AlGaAs multiple quantum well (MQW) avalanche photodiode (APD) structures fabricated by molecular beam epitaxy is investigated. Reliability is examined by accelerated life tests by monitoring dark current and breakdown voltage. Median device lifetime and the activation energy of the degradation mechanism are computed for undoped, doped-barrier, and doped-well APD structures. Lifetimes for each device structure are examined via a statistically designed experiment. Analysis of variance shows that dark-current is affected primarily by device diameter, temperature and stressing time, and breakdown voltage depends on the diameter, stressing time and APD type. It is concluded that the undoped APD has the highest reliability, followed by the doped well and doped barrier devices, respectively. To determine the source of the degradation mechanism for each device structure, failure analysis using the electron-beam induced current method is performed. This analysis reveals some degree of device degradation caused by ionic impurities in the passivation layer, and energy-dispersive spectrometry subsequently verified the presence of ionic sodium as the primary contaminant. However, since all device structures are similarly passivated, sodium contamination alone does not account for the observed variation between the differently doped APDs. This effect is explained by the dopant migration during stressing, which is verified by free carrier concentration measurements using the capacitance-voltage technique.

  3. Impulsive traits and 5-HT2A receptor promoter polymorphism in alcohol dependents: possible association but no influence of personality disorders.

    Science.gov (United States)

    Preuss, U W; Koller, G; Bondy, B; Bahlmann, M; Soyka, M

    2001-01-01

    Impulsive behavior in alcoholics puts them at serious risk of severer course of disease and has been related to the serotonergic neurotransmission dysfunction. The aim of this study is to investigate the association between impulsive aggression in alcohol dependents with regard to the G-1438A polymorphism in the promoter region of the 5-HT2A receptor gene. Furthermore, we investigated the statistical interaction between 5-HT2A alleles, antisocial personality disorder (APD) and impulsive aggression in alcohol dependents. Alcohol dependents were investigated because these personality disorders and impulsive behavior are very frequent in alcohol dependence anf of clinical relevance. One hundred and thirty-five patients of German descent meeting DSM-IV criteria of alcohol dependence were recruited. Blood samples were taken from alcohol dependents to determine 5-HT2A promoter polymorphisms using PCR (polymerase chain reaction) of lymphocyte DNA. Impulsive aggression was assessed using a German version of the Barratt Impulsiveness Scale which was translated and backtranslated. Alcohol dependents were subdivided into low- or high-impulsivity groups using a median split of the Barratt score. APD and borderline personality disorder (BPD) were assessed using the SCID-II interview. The low-impulsivity group was slightly older and showed a later age at alcoholism onset than the highly impulsive group. Alcohol dependents with high impulsive traits showed a significant association with 5-HT2A 1438 A alleles. After excluding alcohol dependents with APD or BPD from the analysis, this association remained significant. Furthermore, no association between APD, BPD and 5-HT2A alleles was noted. Inpatient alcohol dependents showed a significant association between 5-HT2A A alleles and impulsive traits, independent of the presence of APD or BPD. No association was noted between personality disorders and the polymorphism. This is the first report about an association of 5-HT2A promoter

  4. Computational model based approach to analysis ventricular arrhythmias: Effects of dysfunction calcium channels

    Science.gov (United States)

    Gulothungan, G.; Malathi, R.

    2018-04-01

    Disturbed sodium (Na+) and calcium (Ca2+) handling is known to be a major predisposing factor for life-threatening cardiac arrhythmias. Cardiac contractility in ventricular tissue is prominent by Ca2+ channels like voltage dependent Ca2+ channels, sodium-calcium exchanger (Na+-Ca2+x) and sacroplasmicrecticulum (SR) Ca2+ pump and leakage channels. Experimental and clinical possibilities for studying cardiac arrhythmias in human ventricular myocardium are very limited. Therefore, the use of alternative methods such as computer simulations is of great importance. Our aim of this article is to study the impact on action potential (AP) generation and propagation in single ventricular myocyte and ventricular tissue under different dysfunction Ca2+ channels condition. In enhanced activity of Na+-Ca2+x, single myocyte produces AP duration (APD90) and APD50 is significantly smaller (266 ms and 235 ms). Its Na+-Ca2+x current at depolarization is increases 60% from its normal level and repolarization current goes more negative (nonfailing= -0.28 pA/pF and failing= -0.47 pA/pF). Similarly, same enhanced activity of Na+-Ca2+x in 10 mm region of ventricular sheet, raises the plateau potential abruptly, which ultimately affects the diastolic repolarization. Compare with normal ventricular sheet region of 10 mm, 10% of ventricular sheet resting state is reduces and ventricular sheet at time 250 ms is goes to resting state very early. In hypertrophy condition, single myocyte produces APD90 and APD50 is worthy of attention smaller (232 mS and 198 ms). Its sodium-potassium (Na+-K+) pump current is 75% reduces from its control conditions (0.13 pA/pF). Hypertrophy condition, 50% of ventricular sheet is reduces to minimum plateau potential state, that starts the repolarization process very early and reduces the APD. In a single failing SR Ca2+ channels myocyte, recovery of Ca2+ concentration level in SR reduces upto 15% from its control myocytes. At time 290 ms, 70% of ventricular sheet

  5. Differential diagnosis of Parkinsonism using dual phase F 18 FP CIT PET imaging

    Energy Technology Data Exchange (ETDEWEB)

    Jin, So Young; Oh, Min Young; Ok, Seung Jun; Oh, Jung Su; Lee, Sang Ju; Chung, Sun Ju; Lee, Chong Sik; Kim, Jae Seung [Univ. of Ulsan, Seoul (Korea, Republic of)

    2012-03-15

    Dopamine transporter (DAT) imaging can demonstrate presynaptic dopaminergic neuronal loss in Parkinson's disease (PD). However, differentiating atypical parkinsonism (APD) from PD is often difficult. We investigated the usefulness of dual phase F 18 FP CIT positron emission tomography (PET) imaging in the differential diagnosis of parkinsonism. Ninety eight subjects [five normal, seven drug induced parkinsonism (DIP), five essential tremor (ET), 24 PD, 20 multiple system atrophy parkinson type (MSA-P), 13 multiple system atrophy cerebellar type (MSA-C), 13 progressive supranuclear palsy (PSP), and 11 dementia with Lewy bodies(DLB)] underwent F 18 FP CIT PET. PET images were acquired at 5 min (early phase) and 3 h (late phase) after F 18 FP CIT administration (185MBq). Regional uptake pattern of cerebral and cerebellar hemispheres was assessed on early phase images, using visual, quantitative, and statistical parametric mapping (SPM) analyses. Striatal DAT binding was normal in normal, ET, DIP, and MSA C groups, but abnormal in PD, MSA P PSP, and DLB groups. No difference was found in regional uptake on early phase images among normal DAT binding groups, except in the MSA C group. Abnormal DAT binding groups showed different regional uptake pattern on early phase images compared with PD in SPM analysis (FDR<0.05). When discriminating APD from PD, visual interpretation of the early phase image showed high diagnostic sensitivity and specificity (75.4% and 100%, respectively). Regarding the ability to distinguish specific APD, sensitivities were 81% for MSA P, 77% for MSA C, 23% for PSP, and 54.5% for DLB. Dual phase F 18 FP CIT PET imaging is useful in demonstrating striatal DAT loss in neurodegenerative parkinsonism, and also in differentiating APD, particularly MSA, from PD.

  6. Area-preserving diffeomorphisms in gauge theory on a non-commutative plane. A lattice study

    International Nuclear Information System (INIS)

    Bietenholz, W.; Bigarini, A.; INFN, Sezione di Perugia; Humboldt-Universitaet, Berlin; Torrielli, A.

    2007-06-01

    We consider Yang-Mills theory with the U(1) gauge group on a non-commutative plane. Perturbatively it was observed that the invariance of this theory under area-preserving diffeomorphisms (APDs) breaks down to a rigid subgroup SL(2,R). Here we present explicit results for the APD symmetry breaking at finite gauge coupling and finite non-commutativity. They are based on lattice simulations and measurements of Wilson loops with the same area but with a variety of different shapes. Our results confirm the expected loss of invariance under APDs. Moreover, they strongly suggest that non-perturbatively the SL(2,R) symmetry does not persist either. (orig.)

  7. Personality disorders among Danish alcoholics attending outpatient treatment

    DEFF Research Database (Denmark)

    Nordholm, Dorte; Nielsen, Bent

    2007-01-01

    of the Addiction Severity Index. A+PDC had significantly more serious medical problems than A-PD, while the A+PDB group had significantly more employment, drug use and social problems than the A-PD. As for psychiatric status, A-PD had significantly different scores compared with A+PDB and A+PDC. A+PDB were younger...... at the outpatient alcohol clinic at Odense University Hospital, Denmark. It was possible to re-interview 276 (76%) patients 1 year after onset of treatment. Of the 363 patients, 87% were alcohol-dependent (ICD-10) and 34% fulfilled the ICD-10-R criteria for PDs. The basic interviews focused on the seven main areas...

  8. HgCdTe e-avalanche photodiode detector arrays

    Directory of Open Access Journals (Sweden)

    Anand Singh

    2015-08-01

    Full Text Available Initial results on the MWIR e-APD detector arrays with 30 μm pitch fabricated on LPE grown compositionally graded p-HgCdTe epilayers are presented. High dynamic resistance times active area (R0A product 2 × 106 Ω-cm2, low dark current density 4 nA/cm2 and high gain 5500 at -8 V were achieved in the n+-υ-p+ HgCdTe e-APD at 80 K. LPE based HgCdTe e-APD development makes this technology amenable for adoption in the foundries established for the conventional HgCdTe photovoltaic detector arrays without any additional investment.

  9. High precision, low disturbance calibration of the High Voltage system of the CMS Barrel Electromagnetic Calorimeter

    CERN Document Server

    Marzocchi, Badder

    2017-01-01

    The CMS Electromagnetic Calorimeter is made of scintillating lead tungstate crystals, using avalanche photodiodes (APD) as photo-detectors in the barrel part. The high voltage system, consisting of 1224 channels, biases groups of 50 APD pairs, each at a voltage of about 380 V. The APD gain dependence on the voltage is 3pct/V. A stability of better than 60 mV is needed to have negligible impact on the calorimeter energy resolution. Until 2015 manual calibrations were performed yearly. A new calibration system was deployed recently, which satisfies the requirement of low disturbance and high precision. The system is discussed in detail and first operational experience is presented.

  10. Predicting Future Antisocial Personality Disorder in Males from a Clinical Assessment in Childhood

    Science.gov (United States)

    Lahey, Benjamin B.; Loeber, Rolf; Burke, Jeffrey D.; Applegate, Brooks

    2005-01-01

    It is essential to identify childhood predictors of adult antisocial personality disorder (APD) to target early prevention. It has variously been hypothesized that APD is predicted by childhood conduct disorder (CD), attention-deficit/hyperactivity disorder (ADHD), or both disorders. To test these competing hypotheses, the authors used data from a…

  11. Psychological strengths, coping and suicide ideation in the South African Police Services In The North West Province

    Directory of Open Access Journals (Sweden)

    S. Rothmann

    2002-10-01

    Full Text Available Relatively high numbers of suicides occur in the South African Police Services. The objective of this research was to determine the relationship between sense of coherence, generalised self-efficacy, locus of control and coping on the one hand and suicide ideation among police personnel on the other hand. The study population (N = 287 consisted of uniformed police personnel in the North West Province. The results showed that sense of coherence and generalised self-efficacy are related to suicide ideation of police members. A discriminant analysis showed that sense of coherence, coping strategies and medical status correctly classified 81,48% of participants who scored high on suicide ideation. Opsomming ‘n Relatiewe hoë getal selfmoorde kom in die Suid-Afrikaanse Polisiediens voor. Die doelstelling van hierdie navorsing was om die verband tussen koherensiesin, algemene selfdoeltreffendheid, lokus van beheer en coping enersyds en selfmoorddenkbeeldvorming van polisiepersoneel andersyds te bepaal. Die studiepopulasie (N = 287 het bestaan uit polisiepersoneel in die Noordwes-Provinsie. Die resultate het aangetoon dat koherensiesin en algemene selfdoeltreffendheid verband hou met selfmoorddenkbeeldvorming by polisieper-soneel. ‘n Diskriminantontleding het aangetoon dat koherensiesin, coping-strategieë en mediese toestand 81,48% van die deelnemers met hoë tellings ten opsigte van selfmoorddenkbeeldvorming korrek geklassifiseer het.

  12. Cloning and Expression of Plantaricin W Produced by Lactobacillus plantarum U10 Isolate from "Tempoyak" Indonesian Fermented Food as Immunity Protein in Lactococcus lactis.

    Science.gov (United States)

    Lages, Aksar Chair; Mustopa, Apon Zaenal; Sukmarini, Linda; Suharsono

    2015-10-01

    Plantaricins, one of bacteriocin produced by Lactobacillus plantarum, are already known to have activities against several pathogenic bacterium. L. plantarum U10 isolated from "tempoyak," an Indonesian fermented food, produced one kind of plantaricin designated as plantaricin W (plnW). The plnW is suggested as a putative membrane location of protein and has similar conserved motif which is important as immunity to bacteriocin itself. Thus, due to study about this plantaricin, several constructs have been cloned and protein was analyzed in Lactococcus lactis. In this study, plnW gene was successfully cloned into vector NICE system pNZ8148 and created the transformant named L. lactis NZ3900 pNZ8148-WU10. PlnW protein was 25.3 kDa in size. The concentration of expressed protein was significantly increased by 10 ng/mL nisin induction. Furthermore, PlnW exhibited protease activity with value of 2.22 ± 0.05 U/mL and specific activity about 1.65 ± 0.03 U/mg protein with 50 ng/mL nisin induction. Immunity study showed that the PlnW had immunity activity especially against plantaricin and rendered L. lactis recombinant an immunity broadly to other bacteriocins such as pediocin, fermentcin, and acidocin.

  13. The AP diameter of the pelvis: a new criterion for continence in the exstrophy complex?

    International Nuclear Information System (INIS)

    Ait-Ameur, A.; Kalifa, G.; Adamsbaum, C.; Wakim, A.; Dubousset, J.

    2001-01-01

    Reconstructive surgery of bladder exstrophy remains a challenge. By using CT of the pelvis, we suggest a new pre- and post-operative investigative procedure to define the AP diameter (APD) as a predictive criterion for continence in this anomaly. Patients and methods: Three axial CT slices were selected in nine children with exstrophy who had undergone neonatal reconstructive surgery. The three levels selected were the first sacral plate, the mid acetabular plane and the superior pubic spine. We used combined slices to measure: circle APD = distance between the first sacral vertebra and the pubic symphysis. circle Pubic diastasis (PD) circle Three angles defined on the transverse plane of the first sacral vertebra - iliac wing angle, sacropubic angle and acetabular version. In exstrophy, the angles demonstrate opening of the iliac wings and the pubic ramus, and acetabular retroversion compared to controls. Comparisons between controls, continent and incontinent patients reveal that in continent patients, APD increases with growth and seems to be a predictive criterion for continence, independent of diastasis of the pubic symphysis. We believe that CT of the pelvis with measurements of the APD should be performed in all neonates with bladder exstrophy before reconstructive surgery and for better understanding of the malformation. The APD seems to be predictive and may be a major criterion for continence, independent of PD. (orig.)

  14. Paradoxical Effects of Sodium-Calcium Exchanger Inhibition on Torsade de Pointes and Early Afterdepolarization in a Heart Failure Rabbit Model.

    Science.gov (United States)

    Chang, Po-Cheng; Lu, Yu-Ying; Lee, Hui-Ling; Lin, Shien-Fong; Chu, Yen; Wen, Ming-Shien; Chou, Chung-Chuan

    2018-05-03

    Calcium homeostasis plays an important role in development of early afterdepolarizations (EADs) and torsade de pointes (TdP). The role of sodium-calcium exchanger (NCX) inhibition in genesis secondary Ca rise and EADs-TdP is still debated. Dual voltage and intracellular Ca optical mapping were conducted in 6 control and 9 failing rabbit hearts. After baseline electrophysiological and optical mapping studies, E4031 was given to simulate long QT syndrome. ORM-10103 was then administrated to examine the electrophysiological effects on EAD-TdP development. E4031 enhanced secondary Ca rise, EADs development and TdP inducibility in both control and failing hearts. The results showed that ORM-10103 reduced premature ventricular beats (PVBs) but was unable to suppress the inducibility of TdP or EADs. The electrophysiological effects of ORM-10103 included prolongation of action potential duration (APD) and increased APD heterogeneity in failing hearts. ORM10103 had a neutral effect on the amplitude of secondary Cai rise in control and HF groups. In this model, most EADs generated from the long-short APD junction area. In conclusion, highly selective NCX inhibition with ORM-10103 reduced PVB burden but was unable to suppress secondary Ca rise, EADs development nor inducibility of TdP. The possible electrophysiological mechanisms include APD prolongation and increased APD heterogeneity.

  15. PENGARUH MEDIA KOMIK TERHADAP PENGETAHUAN KESEHATAN MATA PADA ANAK

    Directory of Open Access Journals (Sweden)

    Abduh Ridho

    2017-07-01

    Full Text Available Abstract: Influence Of Comic For Children Health Is Knowledge Eye. The prevalence of eye disorders cases is very high, about 13 million cases in children aged 5-15 years. There are several factors caused the eye disorders in children, one of them is lack of knowledge about determining eye disorders prevention behaviour. The purpose of this study was to see the effect of comic media on eye health knowledge in children. The research design used was pre-experimental design with one group pretest-post-test design with 36 samples. The results of this study concluded that comic effect on eye health knowledge on children (p-value = 0,000 <0,05 with mean at pretest 55,00 and mean at posttest 81,48. So the comic effect on the child’s knowledge about eye health disorders. Health education efforts can utilize comic has media as a media of health promotion during school healthcare activities of school children. Abstrak: Pengaruh Media Komik Terhadap Pengetahuan Kesehatan Mata Pada Anak. Prevalensi kasus gangguan mata anak sangat tinggi, sekitar 13 juta kasus pada anak usia 5-15 tahun. Ada beberapa faktor yang melatarbelakangi gangguan mata pada anak, salah satunya yaitu kurangnya pengetahuan mengenai kebiasaan/ perilaku yang dapat mencegah gangguan mata. Tujuan penelitian ini yaitu untuk melihat pengaruh media komik terhadap pengetahuan kesehatan mata pada anak. Desain penelitian yang digunakan adalah pre-experimental design dengan rancangan penelitian one group pre-test and post-test design dengan jumlah sampel sebanyak 36 sampel. Hasil penelitian ini menyimpulkan bahwa komik berpengaruh terhadap pengetahuan kesehatan mata pada anak (p value = 0,000 < 0,05 dengan mean pada saat pre-test 55,00 dan mean saat post-test 81,48. Jadi, komik berpengaruh terhadap pengetahuan anak mengenai gangguan kesehatan mata. Upaya pendidikan kesehatan dapat memanfaatkan media komik sebagai media promosi kesehatan saat kegiatan penjaringan kesehatan anak sekolah.

  16. Characterization and commissioning of the SST-1M camera for the Cherenkov Telescope Array

    Czech Academy of Sciences Publication Activity Database

    Aguilar, J.A.; Bilnik, W.; Blocki, J.; Bogacz, L.; Borkowski, J.; Bulik, T.; Cadoux, F.; Christov, A.; Curylo, M.; della Volpe, D.; Dyrda, M.; Favre, Y.; Frankowski, A.; Grudnik, L.; Grudzinska, M.; Heller, M.; Idzkowski, B.; Jamrozy, M.; Janiak, M.; Kasperek, J.; Lalik, K.; Lyard, E.; Mach, E.; Mandát, Dušan; Marszalek, A.; Medina Miranda, L. D.; Michałowski, J.; Moderski, R.; Montaruli, T.; Neronov, A.; Niemiec, J.; Ostrowski, M.; Pasko, P.; Pech, Miroslav; Porcelli, A.; Prandini, E.; Rajda, P.; Rameez, M.; Schioppa, E.; Schovánek, Petr; Seweryn, K.; Skowron, K.; Sliusar, V.; Sowinski, M.; Stawarz, L.; Stodulska, M.; Stodulski, M.; Toscano, S.; Troyano Pujadas, I.; Walter, R.; Wiecek, M.; Zagdanski, A.; Zietara, K.; Zychowski, P.

    2017-01-01

    Roč. 845, Feb (2017), s. 350-354 ISSN 0168-9002 Institutional support: RVO:68378271 Keywords : SiPM * G-APD * CTA * SST-1 M * Gamma-ray Astronomy * FPGA * PhotoDetection * high-speed electronics * ADC Subject RIV: BF - Elementary Particles and High Energy Physics OBOR OECD: Particles and field physics Impact factor: 1.362, year: 2016

  17. Avoidant Personality Disorder is a Separable Schizophrenia Spectrum Personality Disorder even when Controlling for the Presence of Paranoid and Schizotypal Personality Disorders

    OpenAIRE

    Fogelson, D. L.; Nuechterlein, K. H.; Asarnow, R. A.; Payne, D. L.; Subotnik, K. L.; Jacobson, K. C.; Neale, M. C.; Kendler, K. S.

    2007-01-01

    It is unresolved whether avoidant personality disorder (APD) is an independent schizophrenia (Sz)-spectrum personality disorder (PD). Some studies find APD and social anxiety symptoms (Sxs) to be a separable dimension of psychopathology in relatives (Rels) of schizophrenics while other studies find avoidant Sxs to be correlated with schizotypal and paranoid Sxs.

  18. Development of Antisocial Personality Disorder in Detained Youths: The Predictive Value of Mental Disorders

    Science.gov (United States)

    Washburn, Jason J.; Romero, Erin Gregory; Welty, Leah J.; Abram, Karen M.; Teplin, Linda A.; McClelland, Gary M.; Paskar, Leah D.

    2007-01-01

    Antisocial personality disorder (APD) is a serious public and mental health concern. Understanding how well conduct disorder (CD) and other mental disorders predict the development of APD among youths involved in the juvenile justice system is critical for prevention. The authors used a stratified random sample of 1,112 detained youths to examine…

  19. Modified Therapeutic Community Treatment for Offenders with MICA Disorders: Antisocial Personality Disorder and Treatment Outcomes

    Science.gov (United States)

    McKendrick, Karen; Sullivan, Christopher; Banks, Steven; Sacks, Stanley

    2006-01-01

    Treatment outcomes 1 year after release from prison were compared for two subgroups of male inmates with co-occurring serious mental illness and chemical abuse (MICA) disorders, those with a diagnosis for Antisocial Personality Disorder (APD), and those without a diagnosis of APD. The foundation study had randomly assigned inmates to either…

  20. Short-term action potential memory and electrical restitution: A cellular computational study on the stability of cardiac repolarization under dynamic pacing.

    Directory of Open Access Journals (Sweden)

    Massimiliano Zaniboni

    Full Text Available Electrical restitution (ER is a major determinant of repolarization stability and, under fast pacing rate, it reveals memory properties of the cardiac action potential (AP, whose dynamics have never been fully elucidated, nor their ionic mechanisms. Previous studies have looked at ER mainly in terms of changes in AP duration (APD when the preceding diastolic interval (DI changes and described dynamic conditions where this relationship shows hysteresis which, in turn, has been proposed as a marker of short-term AP memory and repolarization stability. By means of numerical simulations of a non-propagated human ventricular AP, we show here that measuring ER as APD versus the preceding cycle length (CL provides additional information on repolarization dynamics which is not contained in the companion formulation. We focus particularly on fast pacing rate conditions with a beat-to-beat variable CL, where memory properties emerge from APD vs CL and not from APD vs DI and should thus be stored in APD and not in DI. We provide an ion-currents characterization of such conditions under periodic and random CL variability, and show that the memory stored in APD plays a stabilizing role on AP repolarization under pacing rate perturbations. The gating kinetics of L-type calcium current seems to be the main determinant of this safety mechanism. We also show that, at fast pacing rate and under otherwise identical pacing conditions, a periodically beat-to-beat changing CL is more effective than a random one in stabilizing repolarization. In summary, we propose a novel view of short-term AP memory, differentially stored between systole and diastole, which opens a number of methodological and theoretical implications for the understanding of arrhythmia development.

  1. Enhanced basal late sodium current appears to underlie the age-related prolongation of action potential duration in guinea pig ventricular myocytes.

    Science.gov (United States)

    Song, Yejia; Belardinelli, Luiz

    2017-12-14

    Aging hearts have prolonged QT interval and are vulnerable to oxidative stress. Because the QT interval indirectly reflects the action potential duration (APD), we examined the hypotheses that 1) the APD of ventricular myocytes increases with age; 2) the age-related prolongation of APD is due to an enhancement of basal late Na + current (I NaL ); 3) inhibition of I NaL may protect aging hearts from arrhythmogenic effects of hydrogen peroxide (H 2 O 2 ). Experiments were performed on ventricular myocytes isolated from one-month (young) and one-year (old) guinea pigs (GPs). The APD of myocytes from old GPs was significantly longer than that from young GPs and was shortened by the I NaL inhibitors GS967 and tetrodotoxin. The magnitude of I NaL was significantly larger in myocytes from old than from young GPs. The CaMKII inhibitors KN-93 and AIP and the Na V 1.5-channel blocker MTSEA blocked the I NaL . There were no significant differences between myocytes from young and old GPs in L-type Ca 2+ current and the rapidly- and slowly-activating delayed rectifier K + currents, although the inward rectifier K + current was slightly decreased in myocytes from old GPs. H 2 O 2 induced more early afterdepolarizations in myocytes from old than from young GPs. The effect of H 2 O 2 was attenuated by GS967. The results suggest that 1) the APD of myocytes from old GPs is prolonged, 2) a CaMKII-mediated increase in Na V 1.5-channel I NaL is responsible for the prolongation of APD, and 3) Inhibition of I NaL may be beneficial for maintaining electrical stability under oxidative stress in myocytes of old GPs.

  2. New KID dosemeter for measurement of cosmic dosimetry

    International Nuclear Information System (INIS)

    Peksova, D.; Kakona, M.; Krist, P.; Kocur, Z.; Larina, K. V.; Ploc, O.

    2018-01-01

    The KID dosemeter is a small semiconductor low-power detector developed for common use. The current design is special designed after measuring cosmic rays on aircraft decks. The design concept is the same world-class devices Internet of Things (IoT). As a detection element detector were tested three variants a) PIN HAMAMATSU S2744-09 photodiode, b) 9 parallel Vishay photodiodes TEMD5080X01, c) 16 Vishay photodiode TEMD5080X01 again in parallel connection. All variants are silicon PIN photodiode. (authors)

  3. Cryogenic readout for multiple VUV4 Multi-Pixel Photon Counters in liquid xenon

    Science.gov (United States)

    Di Giovanni, A.

    2018-03-01

    This work concerned the preliminary tests and characterization of a cryogenic preamplifier board for an array made of 16 S13370-3050CN (VUV4 family) Multi-Pixel Photon Counters manufactured by Hamamatsu and operated at liquid xenon temperature. The proposed prototype is based on the use of the Analog Devices AD8011 current feedback operational amplifier. The detector allows for single photon detection, making this device a promising choice for the future generation of neutrino and dark matter detectors based on liquid xenon targets.

  4. Extraction of bioactives from Orthosiphon stamineus using microwave and ultrasound-assisted techniques: Process optimization and scale up.

    Science.gov (United States)

    Chan, Chung-Hung; See, Tiam-You; Yusoff, Rozita; Ngoh, Gek-Cheng; Kow, Kien-Woh

    2017-04-15

    This work demonstrated the optimization and scale up of microwave-assisted extraction (MAE) and ultrasonic-assisted extraction (UAE) of bioactive compounds from Orthosiphon stamineus using energy-based parameters such as absorbed power density and absorbed energy density (APD-AED) and response surface methodology (RSM). The intensive optimum conditions of MAE obtained at 80% EtOH, 50mL/g, APD of 0.35W/mL, AED of 250J/mL can be used to determine the optimum conditions of the scale-dependent parameters i.e. microwave power and treatment time at various extraction scales (100-300mL solvent loading). The yields of the up scaled conditions were consistent with less than 8% discrepancy and they were about 91-98% of the Soxhlet extraction yield. By adapting APD-AED method in the case of UAE, the intensive optimum conditions of the extraction, i.e. 70% EtOH, 30mL/g, APD of 0.22W/mL, AED of 450J/mL are able to achieve similar scale up results. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Progress in the use of avalanche photodiodes for readout for calorimeters

    International Nuclear Information System (INIS)

    Fenker, H.; Morgan, K.; Regan, T.

    1991-09-01

    During the past year the Superconducting Super Collider Tracking Group has progressed from acquisition of its first avalanche photodiode (APD) to installation of a 96-channel array of the devices. The work was motivated by the desire to learn how to use APDs as the sensitive elements in a fiber tracking detector, moderated by the presence of limited resources and the absence of activity within groups outside the SSC Laboratory on such a project. We chose, therefore, to team up with an ongoing research effort which intended to evaluate both pre-shower and shower-maximum detectors and various means of sensing the light produced. The pre-shower detector is made of layers of scintillating fibers similar to a fiber tracker. The shower-maximum detector uses optical fibers to transmit the light from scintillating plates to the readout devices. Our contribution has been to develop the APD array for use in this test from concept to operation. Currently, the equipment is installed in Fermilab's MP beamline awaiting delivery to the final 36 APDs and exposure to the beam. 9 refs., 18 figs

  6. High peritoneal transport status is not an independent risk factor for high mortality in patients treated with automated peritoneal dialysis.

    Science.gov (United States)

    Chang, Tae Ik; Park, Jung Tak; Lee, Dong Hyung; Lee, Ju Hyun; Yoo, Tae Hyun; Kim, Beom Seok; Kang, Shin-Wook; Lee, Ho Yung; Choi, Kyu Hun

    2010-09-01

    We undertook this study to elucidate whether baseline peritoneal membrane transport characteristics are associated with high mortality in incident automated peritoneal dialysis (APD) patients. This retrospective study includes 117 patients who started APD at Yonsei University Health System from 1996 to 2008 and had a PET within 3 months of APD initiation. High transporters were significantly older and had a higher incidence of cardiovascular disease. Patient survival for years 1, 3, and 5 were 85%, 64%, and 35% for high transporter and 94%, 81%, and 68% for non-high transporter group (Ptransport status was not a significant predictor for mortality in this population when the other covariates were included. Even though high transport was significantly associated with mortality in the univariate analysis, its role seemed to be influenced by other comorbid conditions. These findings suggest that the proper management of these comorbid conditions, as well as appropriate ultrafiltration by use of APD and/or icodextrin, must be considered as protective strategies to improve survival in peritoneal dialysis patients with high transport.

  7. Large area APDs for low energy X-ray detection in intense magnetic fields

    International Nuclear Information System (INIS)

    Boucher, M.; Huot, O.; Knowles, P.E.; Ludhova, L.; Mulhauser, F.; Schaller, L.A.; Conde, C.A.N.; Santos, J.M.F. dos; Fernandes, L.M.P.; Veloso, J.F.C.A.; Kottmann, F.; Antognini, A.; Pohl, R.; Taqqu, D.

    2003-01-01

    An experiment to measure the energy difference between the 2S-2P atomic levels (Lamb shift) in muonic hydrogen is being prepared at PSI. Since the energy levels of muonic hydrogen are a factor of 186 more energetic than those of hydrogen, according to the ratio of reduced masses, the transitions lie in the soft X-ray region. The experiment needs long-lived muonic hydrogen in the 2S state. This is achieved by stopping a low energy muon beam in a small volume of low pressure hydrogen in a 5 T magnetic field. A pulsed beam from a tunable laser induces the 2S-2P transition and the 1.9 keV X-ray photons resulting from the 2P-1S deexcitation will be detected. Measuring the coincidences between the laser pulse and the X-ray as a function of the laser wavelength allows us to determine the Lamb shift. In this presentation we will discuss the perspectives of using large area avalanche photodiodes for the direct detection of the X-rays. Compared to gaseous detectors, they are more compact and simpler in operation. They are also insensitive to magnetic fields

  8. Large area APDs for low energy X-ray detection in intense magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Boucher, M.; Huot, O.; Knowles, P.E.; Ludhova, L.; Mulhauser, F. E-mail: francoise.mulhauser@unifr.ch; Schaller, L.A.; Conde, C.A.N.; Santos, J.M.F. dos; Fernandes, L.M.P.; Veloso, J.F.C.A.; Kottmann, F.; Antognini, A.; Pohl, R.; Taqqu, D

    2003-06-01

    An experiment to measure the energy difference between the 2S-2P atomic levels (Lamb shift) in muonic hydrogen is being prepared at PSI. Since the energy levels of muonic hydrogen are a factor of 186 more energetic than those of hydrogen, according to the ratio of reduced masses, the transitions lie in the soft X-ray region. The experiment needs long-lived muonic hydrogen in the 2S state. This is achieved by stopping a low energy muon beam in a small volume of low pressure hydrogen in a 5 T magnetic field. A pulsed beam from a tunable laser induces the 2S-2P transition and the 1.9 keV X-ray photons resulting from the 2P-1S deexcitation will be detected. Measuring the coincidences between the laser pulse and the X-ray as a function of the laser wavelength allows us to determine the Lamb shift. In this presentation we will discuss the perspectives of using large area avalanche photodiodes for the direct detection of the X-rays. Compared to gaseous detectors, they are more compact and simpler in operation. They are also insensitive to magnetic fields.

  9. Change of short-term memory effect in acute ischemic ventricular myocardium: a computational study.

    Science.gov (United States)

    Mei, Xi; Wang, Jing; Zhang, Hong; Liu, Zhi-cheng; Zhang, Zhen-xi

    2014-02-01

    The ionic mechanism of change in short-term memory (STM) during acute myocardial ischemia has not been well understood. In this paper, an advanced guinea pig ventricular model developed by Luo and Rudy was used to investigate STM property of ischemic ventricular myocardium. STM response was calculated by testing the time to reach steady-state action potential duration (APD) after an abrupt shortening of basic cycling length (BCL) in the pacing protocol. Electrical restitution curves (RCs), which can simultaneously visualize multiple aspects of APD restitution and STM, were obtained from dynamic and local S1S2 restitution portrait (RP), which consist of a longer interval stimulus (S1) and a shorter interval stimulus (S2). The angle between dynamic RC and local S1S2 RC reflects the amount of STM. Our results indicated that compared with control (normal) condition, time constant of STM response in the ischemic condition decreased significantly. Meanwhile the angle which reflects STM amount is less in ischemic model than that in control model. By tracking the effect of ischemia on intracellular ion concentration and membrane currents, we declared that changes in membrane currents caused by ischemia exert subtle influences on STM; it is only the decline of intracellular calcium concentration that give rise to the most decrement of STM. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  10. A gamma- and X-ray detector for cryogenic, high magnetic field applications

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, R.L., E-mail: roblcoop@indiana.edu [Indiana University, Bloomington, IN 47408 (United States); Alarcon, R. [Arizona State University, Tempe, AZ 85287 (United States); Bales, M.J. [University of Michigan, Ann Arbor, MI 48109 (United States); Bass, C.D. [National Institute of Standards and Technology, Stop 8461, NIST, Gaithersburg, MD 20899 (United States); Beise, E.J. [University of Maryland, College Park, MD 20742 (United States); Breuer, H., E-mail: breuer@enp.umd.edu [University of Maryland, College Park, MD 20742 (United States); Byrne, J. [University of Sussex, Brighton, BN1 9QH (United Kingdom); Chupp, T.E. [University of Michigan, Ann Arbor, MI 48109 (United States); Coakley, K.J. [National Institute of Standards and Technology, Boulder, CO 80305 (United States); Dewey, M.S.; Fu, C. [National Institute of Standards and Technology, Stop 8461, NIST, Gaithersburg, MD 20899 (United States); Gentile, T.R., E-mail: thomas.gentile@nist.gov [National Institute of Standards and Technology, Stop 8461, NIST, Gaithersburg, MD 20899 (United States); Mumm, H.P.; Nico, J.S. [National Institute of Standards and Technology, Stop 8461, NIST, Gaithersburg, MD 20899 (United States); O' Neill, B. [Arizona State University, Tempe, AZ 85287 (United States); Pulliam, K. [Tulane University, New Orleans, LA 70118 (United States); Thompson, A.K. [National Institute of Standards and Technology, Stop 8461, NIST, Gaithersburg, MD 20899 (United States); Wietfeldt, F.E. [Tulane University, New Orleans, LA 70118 (United States)

    2012-11-01

    As part of an experiment to measure the spectrum of photons emitted in beta-decay of the free neutron, we developed and operated a detector consisting of 12 bismuth germanate (BGO) crystals coupled to avalanche photodiodes (APDs). The detector was operated near liquid nitrogen temperature in the bore of a superconducting magnet and registered photons with energies from 5 keV to 1000 keV. To enlarge the detection range, we also directly detected soft X-rays with energies between 0.2 keV and 20 keV with three large area APDs. The construction and operation of the detector are presented, as well as information on operation of APDs at cryogenic temperatures.

  11. [Dialectical behavior therapy approaches with disruptive behavior disorders].

    Science.gov (United States)

    Stadler, Christina; Manetsch, Madleina; Vriends, Noortje

    2016-11-01

    Disruptive behaviour disorders comprise the diagnosis conduct disorder (CD) and in adults the diagnosis antisocial personality disorder (APD). CD is seen as a difficult-to-treat disorder with a high risk for persistent behavioral problems. In addition, CD is seen as the precursor to antisocial personality disorder (Kretschmer et al., 2014). Dialectical behavior therapy (DBT) was originally developed by Marsha Linehan (1991) for the treatment of borderline personality disorder, but because of the core deficits in emotion regulation in disruptive behavior disorders, DBT is also increasingly being recommended for the treatment of CD and APD. This review presents DBT adaptions for the forensic setting and for the treatment of CD/APD. Clinical implications are discussed.

  12. Radiation hardness tests of SiPMs for the JLab Hall D Barrel calorimeter

    International Nuclear Information System (INIS)

    Qiang, Yi; Zorn, Carl; Barbosa, Fernando; Smith, Elton

    2013-01-01

    We report on the measurement of the neutron radiation hardness of silicon photomultipliers (SiPMs) manufactured by Hamamatsu Corporation in Japan and SensL in Ireland. Samples from both companies were irradiated by neutrons created by a 1 GeV electron beam hitting a thin lead target at Jefferson Lab Hall A. More tests regarding the temperature dependence of the neutron radiation damage and self-annealing were performed on Hamamatsu SiPMs using a calibrated Am–Be neutron source from the Jefferson Lab Radiation Control group. As the result of irradiation both dark current and dark rate increase linearly as a function of the 1 MeV equivalent neutron fluence and a temperature dependent self-annealing effect is observed.

  13. Study on the property of the avalanche photodiode as the readout component for scintillation crystals

    International Nuclear Information System (INIS)

    He Jingtang; Chen Duanbao; Zhu Guoyi; Mao Yufang; Dong Xiaoli; Li Zuhao

    1996-01-01

    The new avalanche photodiode (APD) and a CsI(Tl) crystal formed a scintillation detector. The energy spectrum of γ rays was measured by this detector. The measured results were compared with that measured by photomultiplier. Our plan is to use APD as PbWO 4 readout component for forward luminosity electromagnetic calorimeter at τ-C factory

  14. The ticking of the epigenetic clock: antipsychotic drugs in old age

    Directory of Open Access Journals (Sweden)

    Adonis Sfera

    2016-08-01

    Full Text Available AbstractBackground: Exposed to antipsychotic drugs (APDs, older individuals with dementing illness are at risk of cerebrovascular adverse effects (CVAE, including sudden death. Transient microvascular dysfunctions are known to occur in younger persons exposed to APDs, however they seldom progresses to CVAE, suggesting that APDs alone are insufficient for engendering this untoward effect. It is, therefore believed that a preexistent microvascular damage is necessary for CVAE to take place, but the exact nature of this lesion remains unclear.CNS small vessel disease (SVD is a well-known age-related risk factor for strokes, dementia and sudden death, which may constitute the initial CVAE-predisposing pathology. We therefore propose a two strike CVAE paradigm in which SVD represents the first strike, while exposure to APDs, the second. In this model, both strikes must be present for CVAE to take place, and the neuroimaging load of white matter hyperintensities (WMH may be directly proportional with the CVAE risk.To investigate this hypothesis at the molecular level, we focused on a seemingly unrelated phenomenon: both APDs and SVD were found protective against a similar repertoire of cancers and their spread to the brain (1-4. Since microRNA-29 has shown efficacy against the same malignancies, and has been associated with small vessels pathology, we narrowed our search down to this miR, hypothesizing that the APDs mechanism of action includes miR-29 up-regulation, which in turn facilitates the development of SVD. Aim: to assess whether miR-29 can be utilized as a peripheral blood biomarker for SVD and CVAE risk.Method: we conducted a search of experimentally verified miR-29 target genes utilizing the public domain tools miRanda, RNA22 and Weizemann Institute of Science miRNA Analysis. We identified in total 67 experimentally verified target genes for miR-29 family, 18 of which correlate with microvascular integrity, and may be relevant for CVAE

  15. Arctigenin, a Potential Anti-Arrhythmic Agent, Inhibits Aconitine-Induced Arrhythmia by Regulating Multi-Ion Channels

    Directory of Open Access Journals (Sweden)

    Zhenying Zhao

    2013-11-01

    Full Text Available Background/Aims: Arctigenin possesses biological activities, but its underlying mechanisms at the cellular and ion channel levels are not completely understood. Therefore, the present study was designed to identify the anti-arrhythmia effect of arctigenin in vivo, as well as its cellular targets and mechanisms. Methods: A rat arrhythmia model was established via continuous aconitine infusion, and the onset times of ventricular premature contraction, ventricular tachycardia and death were recorded. The Action Potential Duration (APD, sodium current (INa, L-type calcium current (ICa, L and transient outward potassium current (Ito were measured and analysed using a patch-clamp recording technique in normal rat cardiomyocytes and myocytes of arrhythmia aconitine-induced by. Results: Arctigenin significantly delayed the arrhythmia onset in the aconitine-induced rat model. The 50% and 90% repolarisations (APD50 and APD90 were shortened by 100 µM arctigenin; the arctigenin dose also inhibited the prolongation of APD50 and APD90 caused by 1 µM aconitine. Arctigenin inhibited INa and ICa,L and attenuated the aconitine-increased INa and ICa,L by accelerating the activation process and delaying the inactivation process. Arctigenin enhanced Ito by facilitating the activation process and delaying the inactivation process, and recoverd the decreased Ito induced by aconitine. Conclusions: Arctigenin has displayed anti-arrhythmia effects, both in vivo and in vitro. In the context of electrophysiology, INa, ICa, L, and Ito may be multiple targets of arctigenin, leading to its antiarrhythmic effect.

  16. Harsh-Environment Solid-State Gamma Detector for Down-hole Gas and Oil Exploration

    International Nuclear Information System (INIS)

    Peter Sandvik; Stanislav Soloviev; Emad Andarawis; Ho-Young Cha; Jim Rose; Kevin Durocher; Robert Lyons; Bob Pieciuk; Jim Williams; David O'Connor

    2007-01-01

    The goal of this program was to develop a revolutionary solid-state gamma-ray detector suitable for use in down-hole gas and oil exploration. This advanced detector would employ wide-bandgap semiconductor technology to extend the gamma sensor's temperature capability up to 200 C as well as extended reliability, which significantly exceeds current designs based on photomultiplier tubes. In Phase II, project tasks were focused on optimization of the final APD design, growing and characterizing the full scintillator crystals of the selected composition, arranging the APD device packaging, developing the needed optical coupling between scintillator and APD, and characterizing the combined elements as a full detector system preparing for commercialization. What follows is a summary report from the second 18-month phase of this program

  17. X-ray fluorescence hologram data collection with a cooled avalanche photodiode

    CERN Document Server

    Hayashi, K; Matsubara, E I; Kishimoto, S; Mori, T; Tanaka, M

    2002-01-01

    A high counting rate X-ray detector with an appropriate energy resolution is desired for high quality X-ray fluorescence hologram measurements because a holographic pattern is detected as extremely small intensity variations of X-ray fluorescence on a large intensity background. A cooled avalanche photodiode (APD), which has about 10% energy resolution and is designed for a high counting rate, fits the above requirements. Reconstructed atomic images from experimental holograms using the APD system provide us a clear view of the first and second neighbor atoms around an emitter. The present result proved that a combination of this APD system and a synchrotron X-ray source enables us to measure a high quality hologram for a reasonable measurement time.

  18. Best-Practice Criteria for Practical Security of Self-Differencing Avalanche Photodiode Detectors in Quantum Key Distribution

    Science.gov (United States)

    Koehler-Sidki, A.; Dynes, J. F.; Lucamarini, M.; Roberts, G. L.; Sharpe, A. W.; Yuan, Z. L.; Shields, A. J.

    2018-04-01

    Fast-gated avalanche photodiodes (APDs) are the most commonly used single photon detectors for high-bit-rate quantum key distribution (QKD). Their robustness against external attacks is crucial to the overall security of a QKD system, or even an entire QKD network. We investigate the behavior of a gigahertz-gated, self-differencing (In,Ga)As APD under strong illumination, a tactic Eve often uses to bring detectors under her control. Our experiment and modeling reveal that the negative feedback by the photocurrent safeguards the detector from being blinded through reducing its avalanche probability and/or strengthening the capacitive response. Based on this finding, we propose a set of best-practice criteria for designing and operating fast-gated APD detectors to ensure their practical security in QKD.

  19. Relations among symptoms of social phobia subtypes, avoidant personality disorder, panic, and depression.

    Science.gov (United States)

    Carter, Shawn A; Wu, Kevin D

    2010-03-01

    This study's primary goal was to examine relations between symptoms of specific social phobia (SSP), generalized social phobia (GSP), avoidant personality disorder (APD), and panic and depression. Past research has suggested a single social phobia continuum in which SSP displays less symptom severity than GSP or APD. We found SSP symptoms correlated less strongly with depression but more strongly with panic relative to both GSP and APD symptoms. These findings challenge a unidimensional model of social phobia, suggesting a multidimensional model may be more appropriate. These findings also inform current research aimed at classifying mood and anxiety disorders more broadly by identifying that the different factors of fear versus distress appear to underlie different subtypes of social phobia. 2008. Published by Elsevier Ltd.

  20. The front-end electronics and slow control of large area SiPM for the SST-1M camera developed for the CTA experiment

    Czech Academy of Sciences Publication Activity Database

    Aguilar, J.A.; Bilnik, W.; Borkowski, J.; Mandát, Dušan; Pech, Miroslav; Schovánek, Petr

    Roč. 830, Sep (2016), s. 219-232 ISSN 0168-9002 R&D Projects: GA MŠk LM2015046; GA MŠk LE13012; GA MŠk LG14019 Institutional support: RVO:68378271 Keywords : CTA * SiPM * G-APD * preamplifier * front-end * slow-control * compensation Subject RIV: BF - Elementary Particles and High Energy Physics Impact factor: 1.362, year: 2016

  1. Karakteristik Dan Pergerakan Sebaran Penderita DBD Berdasarkan Geographic Information System Sebagai Bagian Sistem Informasi Surveilans di Kecamatan Karawang Barat Kabupaten Karawang Provinsi Jawa Barat

    Directory of Open Access Journals (Sweden)

    Doni Lasut

    2009-06-01

    Full Text Available West Karawang is a part of Karawang District that have high case incidence in three years later. This research uses cross sectional study method was conducted that aimed to gain information of mapping DHF endemic region use GIS (Geographic Information sys-tems as a part of surveillance informatics system 2008. The special goals are to know the spatial aspect of the movement pattern , sociodemographic, larvae index, vector control programs, land systems and precipitation. The results of study are movement pattern of DHF in West Karawang is local, the sociodemographic of sex and marital status there are no special different, group of class age 15 – 44 years old (53,70%, non-formal working (81,48% is the highest. The sociodemographic of education Senior High School (38,89% is the highest too. Almost of The housing type permanent (94,44% is the dominant and the average wide building 50-100 meters (66,67% is the highest. House index larvae is 55,10% and container larvae index is 15,51%. The vector control program of fogging in study area 70,37% is done and PSN program activity (81,48% this fact shown that there are many possibility for breeding place in this district. The Use of GIS helps to handle huge of data easily and much more information can be display clearly.

  2. Diagnostic accuracy of neonatal kidney ultrasound in children having antenatal hydronephrosis without ureter and bladder abnormalities.

    Science.gov (United States)

    Rianthavorn, Pornpimol; Limwattana, Sorawan

    2015-10-01

    To determine the diagnostic accuracy of anteroposterior renal pelvic diameter (APD) measurement and the society for fetal urology (SFU) grading in neonatal ultrasonography (USG) for detecting uropathy in newborns having antenatal isolated hydronephrosis (IH), characterized by hydronephrosis without ureter and bladder abnormalities, and to study time to resolution and factors predicting resolution of insignificant hydronephrosis. Ninety-six healthy newborns (129 kidneys) with IH, who underwent USG at age 7-30 days and voiding cystourethrography (VCUG) in conjunction with diuretic renography (DR) if APD > 10 mm or SFU grade 3-4 in neonatal USG, and at least a 12-month follow-up were divided into significant and insignificant hydronephrosis using the combined data of sequential USG, VCUG, and DR as the reference standard. Areas under the receiver operating characteristic plots (95 % CI) were 0.86 (0.79-0.94) versus 0.81 (0.73-0.89); p = 0.08, and 87.6 versus 79.8 % of cases were correctly classified, for APD ≥ 16 mm versus SFU grade 4, respectively. Ureteropelvic junction obstruction (UPJO) was the most common uropathy diagnosed. Of 85 kidneys with insignificant hydronephrosis, 57 underwent spontaneous resolution. The resolution rates were 24, 40, and 68 % at age 6, 12, and 24 months, respectively. APD was the only independent factor predicting resolution with the hazard ratio of 0.83 (95 % CI 0.74-0.92; p = 0.001). In IH, neonatal USG was a useful diagnostic tool to detect uropathy, mainly UPJO. Further investigation should be recommended when APD ≥ 16 mm or SFU grade 4.

  3. Direct formation of gasoline hydrocarbons from cellulose by hydrothermal conversion with in situ hydrogen

    International Nuclear Information System (INIS)

    Yin, Sudong; Mehrotra, Anil Kumar; Tan, Zhongchao

    2012-01-01

    A new process based on aqueous-phase dehydration/hydrogenation (APD/H) has been developed to directly produce liquid alkanes (C 7–9 ), which are the main components of fossil gasoline, from cellulose in one single batch reactor without the consumption of external hydrogen (H 2 ). In this new process, part of the cellulose is first converted to in situ H 2 by steam reforming (SR) in the steam gas phase mainly; and, in the liquid water phase, cellulose is converted to an alkane precursor, such as 5-(hydroxymethyl)furfural (HMF). In the final reaction step, in situ H 2 reacts with HMF to form liquid alkanes through APD/H. Accordingly, this new process has been named SR(H 2 )-APD/H. Experimental results show that the volumetric ratio of the reactor headspace to the reactor (H/R) and an initial weakly alkaline condition are the two key parameters for SR(H 2 )-APD/H. With proper H/R ratios (e.g., 0.84) and initial weakly alkaline conditions (e.g., pH = 7.5), liquid alkanes are directly formed from the SR(H 2 )-APD/H of cellulose using in situ H 2 instead of external H 2 . In this study, compared with pyrolysis and hydrothermal liquefaction of cellulose at the same temperatures with same retetion time, SR(H 2 )-APD/H greatly increased the liquid alkane yields, by approximately 700 times and 35 times, respectively. Based on this process, direct formation of fossil gasoline from renewable biomass resources without using external H 2 becomes possible. -- Highlights: ► A process of producing gasoline alkanes from cellulose was proposed and studied. ► Alkane precursors and in situ H 2 were formed simultaneously in a single reactor. ► Alkanes subsequently formed by reactions between in situ H 2 and alkane precursors. ► The yields were 700 and 35 times higher than pyrolysis and hydrothermal conversion.

  4. Predictors for the need of surgery in antenatally detected hydronephrosis due to UPJ obstruction--a prospective multivariate analysis.

    Science.gov (United States)

    Arora, S; Yadav, P; Kumar, M; Singh, S Kumar; Sureka, S Kumar; Mittal, V; Ansari, M S

    2015-10-01

    Disagreement exists over the ability of different diagnostic tests to define obstruction, indications and timing of surgery and which patients will benefit from surgical intervention in antenatal hydronephrosis (ANH) due to ureteropelvic junction obstruction (UPJO). We try to find a way to predict which patients of ANH due to UPJO will eventually need surgery during conservative management. Prospective single centre study involving 122 renal units at a referral centre in India. Patients on conservative management were followed using a standard protocol and operated for pre-defined indications defining failure of conservative management. Patients who underwent surgery were compared with the non-operated group in terms of sex, side, baseline grade of hydronephrosis, maximum anterioposterior diameter on first postnatal ultrasound and differential renal function on first renal scan. A total of 109 renal units qualified for conservative management. Of those, 23.9% required operative intervention during follow-up. Median time to failure of conservative management was 37 weeks. The median follow-up of non-operated cases was 54 months. Univariate analysis revealed that society of fetal urology (SFU) grade of hydronephrosis, anteroposterior diameter (APD), cortical thickness (CT), and pre-operative differential renal function (DRF) had a significant association with surgery (P hydronephrosis were not. Receiver operating curve analysis showed that an APD of 24.3 mm could predict the need for surgery, with a sensitivity of 73.1% and a specificity of 88.0%. APD and DRF are the predictive factors for surgery. We stop short of recommending surgery only on the basis of APD. Instead we recommend that efforts be made to improve the specificity of this criterion, or by using APD in perspective with the differential renal function. We can reduce the burden of investigations in those with APD 24 mm can be more comprehensively monitored. Copyright © 2015 Journal of Pediatric Urology

  5. Overexpression of the Large-Conductance, Ca2+-Activated K+ (BK) Channel Shortens Action Potential Duration in HL-1 Cardiomyocytes.

    Science.gov (United States)

    Stimers, Joseph R; Song, Li; Rusch, Nancy J; Rhee, Sung W

    2015-01-01

    Long QT syndrome is characterized by a prolongation of the interval between the Q wave and the T wave on the electrocardiogram. This abnormality reflects a prolongation of the ventricular action potential caused by a number of genetic mutations or a variety of drugs. Since effective treatments are unavailable, we explored the possibility of using cardiac expression of the large-conductance, Ca2+-activated K+ (BK) channel to shorten action potential duration (APD). We hypothesized that expression of the pore-forming α subunit of human BK channels (hBKα) in HL-1 cells would shorten action potential duration in this mouse atrial cell line. Expression of hBKα had minimal effects on expression levels of other ion channels with the exception of a small but significant reduction in Kv11.1. Patch-clamped hBKα expressing HL-1 cells exhibited an outward voltage- and Ca2+-sensitive K+ current, which was inhibited by the BK channel blocker iberiotoxin (100 nM). This BK current phenotype was not detected in untransfected HL-1 cells or in HL-1 null cells sham-transfected with an empty vector. Importantly, APD in hBKα-expressing HL-1 cells averaged 14.3 ± 2.8 ms (n = 10), which represented a 53% reduction in APD compared to HL-1 null cells lacking BKα expression. APD in the latter cells averaged 31.0 ± 5.1 ms (n = 13). The shortened APD in hBKα-expressing cells was restored to normal duration by 100 nM iberiotoxin, suggesting that a repolarizing K+ current attributed to BK channels accounted for action potential shortening. These findings provide initial proof-of-concept that the introduction of hBKα channels into a cardiac cell line can shorten APD, and raise the possibility that gene-based interventions to increase hBKα channels in cardiac cells may hold promise as a therapeutic strategy for long QT syndrome.

  6. THE EVALUATION OF FREQUENCY AND SEASONAL VARIATIONS OF ACID PEPTIC DISEASE: A SEVEN YEARS STUDY

    Directory of Open Access Journals (Sweden)

    Syed Iftikhar Haider

    2016-06-01

    Full Text Available Acid peptic disease (APD is a worldwide health problem. It includes a variety of inflammatory and ulcerative lesions involving esophagus, stomach and duodenum. The disease condition may persist with multiple symptoms, one of them being dyspepsia. The object of the present study was to determine the frequency and seasonal variations of APD in patients presenting with dyspeptic symptoms. This observational study was carried out at the endoscopy unit in Baqai Medical University from December 2003 to December 2010, over a period of seven years. The evolution of APD frequency remained equivocal throughout the study period. However, a decline was noted in the frequency of peptic ulcer disease (PUD especially for gastric and duodenal ulcer cases but a rise during autumn and winter seasons was also noted in duodenal ulcer cases.

  7. An excess noise measurement system for weak responsivity avalanche photodiodes

    Science.gov (United States)

    Qiao, Liang; Dimler, Simon J.; Baharuddin, Aina N. A. P.; Green, James E.; David, John P. R.

    2018-06-01

    A system for measuring, with reduced photocurrent, the excess noise associated with the gain in avalanche photodiodes (APDs), using a transimpedance amplifier front-end and based on phase-sensitive detection is described. The system can reliably measure the excess noise power of devices, even when the un-multiplied photocurrent is low (~10 nA). This is more than one order of magnitude better than previously reported systems and represents a significantly better noise signal to noise ratio. This improvement in performance has been achieved by increasing the value of the feedback resistor and reducing the op-amp bandwidth. The ability to characterise APD performance with such low photocurrents enables the use of low power light sources such as light emitting diode rather than lasers to investigate the APD noise performance.

  8. A lens-coupled scintillation counter in cryogenic environment

    International Nuclear Information System (INIS)

    Stoykov, A; Scheuermann, R; Amato, A; Bartkowiak, M; Konter, J A; Rodriguez, J; Sedlak, K

    2011-01-01

    In this work we present an elegant solution for a scintillation counter to be integrated into a cryogenic system. Its distinguishing feature is the absence of a continuous light guide coupling the scintillation and the photodetector parts, operating at cryogenic and room temperatures respectively. The prototype detector consists of a plastic scintillator with glued-in wavelength-shifting fiber located inside a cryostat, a Geiger-mode Avalanche Photodiode (G-APD) outside the cryostat, and a lens system guiding the scintillation light re-emitted by the fiber to the G-APD through optical windows in the cryostat shields. With a 0.8 mm diameter multiclad fiber and a 1 mm active area G-APD the coupling efficiency of the 'lens light guide' is about 50%. A reliable performance of the detector down to 3 K is demonstrated.

  9. Intercomparison of personal dose equivalent measurements by active personal dosimeters. Final report of a joint IAEA-EURADOS project

    International Nuclear Information System (INIS)

    2007-11-01

    Active personal dosimeters (APD) are widely used in many countries, i.e. in the medical field and as operational dosimeters in nuclear power plants. Their use as legal dosimeters is already established in a few countries, and will increase in the near future. In the majority of countries, APDs have not undergone accreditation programmes or intercomparisons. In 2001, an EURADOS (European Radiation Dosimetry Group) Working Group on harmonization of individual monitoring was formed, funded by the European Commission, in the fifth framework programme, and by the participating institutes. The work addressed four issues; inter alia also an inventory of new developments in individual monitoring with an emphasis on the possibilities and performance of active (electronic) dosimeters for both photon/beta and neutron dosimetry. Within the work on this issue, a catalogue of the most extensively used active personal dosimeters (APDs) suitable for individual monitoring was made. On the basis of the knowledge gained in this activity, the organization of an international intercomparison, which would address APDs, was considered of great value to the dosimetric community. The IAEA in cooperation with EURADOS organized such an intercomparison in which most of the testing criteria as described in two internationally accepted standards (IEC61526 and IEC61283) were used. Additionally, simulated workplace fields were used for testing the APD reactions to pulsed X ray fields and mixed gamma/X ray fields. This is the first time that results of comparisons of such types are published, which is of great importance for APD end users in medical diagnostic and surgery X ray applications. Nine suppliers from six countries in Europe and the USA participated in the intercomparison with 13 different models. One of the models was a special design for extremity dose measurements. Irradiations and readout was done by two accredited calibration laboratories in Belgium and France and the French

  10. A quantitative and efficient approach to select MIRU-VNTR loci based on accumulation of the percentage differences of strains for discriminating divergent Mycobacterium tuberculosis sublineages.

    Science.gov (United States)

    Pan, Xin-Ling; Zhang, Chun-Lei; Nakajima, Chie; Fu, Jin; Shao, Chang-Xia; Zhao, Li-Na; Cui, Jia-Yi; Jiao, Na; Fan, Chang-Long; Suzuki, Yasuhiko; Hattori, Toshio; Li, Di; Ling, Hong

    2017-07-26

    Although several optimal mycobacterial interspersed repetitive units-variable number tandem repeat (MIRU-VNTR) loci have been suggested for genotyping homogenous Mycobacterium tuberculosis, including the Beijing genotype, a more efficient and convenient selection strategy for identifying optimal VNTR loci is needed. Here 281 M. tuberculosis isolates were analyzed. Beijing genotype and non-Beijing genotypes were identified, as well as Beijing sublineages, according to single nucleotide polymorphisms. A total of 22 MIRU-VNTR loci were used for genotyping. To efficiently select optimal MIRU-VNTR loci, we established accumulations of percentage differences (APDs) between the strains among the different genotypes. In addition, we constructed a minimum spanning tree for clustering analysis of the VNTR profiles. Our findings showed that eight MIRU-VNTR loci displayed disparities in h values of ≥0.2 between the Beijing genotype and non-Beijing genotype isolates. To efficiently discriminate Beijing and non-Beijing genotypes, an optimal VNTR set was established by adding loci with APDs ranging from 87.2% to 58.8%, resulting in the construction of a nine-locus set. We also found that QUB11a is a powerful locus for separating ST10s (including ST10, STF and STCH1) and ST22s (including ST22 and ST8) strains, whereas a combination of QUB11a, QUB4156, QUB18, Mtub21 and QUB26 could efficiently discriminate Beijing sublineages. Our findings suggested that two nine-locus sets were not only efficient for distinguishing the Beijing genotype from non-Beijing genotype strains, but were also suitable for sublineage genotyping with different discriminatory powers. These results indicate that APD represents a quantitative and efficient approach for selecting MIRU-VNTR loci to discriminate between divergent M. tuberculosis sublineages.

  11. A quantitative and efficient approach to select MIRU–VNTR loci based on accumulation of the percentage differences of strains for discriminating divergent Mycobacterium tuberculosis sublineages

    Science.gov (United States)

    Pan, Xin-Ling; Zhang, Chun-Lei; Nakajima, Chie; Fu, Jin; Shao, Chang-Xia; Zhao, Li-Na; Cui, Jia-Yi; Jiao, Na; Fan, Chang-Long; Suzuki, Yasuhiko; Hattori, Toshio; Li, Di; Ling, Hong

    2017-01-01

    Although several optimal mycobacterial interspersed repetitive units–variable number tandem repeat (MIRU–VNTR) loci have been suggested for genotyping homogenous Mycobacterium tuberculosis, including the Beijing genotype, a more efficient and convenient selection strategy for identifying optimal VNTR loci is needed. Here 281 M. tuberculosis isolates were analyzed. Beijing genotype and non-Beijing genotypes were identified, as well as Beijing sublineages, according to single nucleotide polymorphisms. A total of 22 MIRU–VNTR loci were used for genotyping. To efficiently select optimal MIRU–VNTR loci, we established accumulations of percentage differences (APDs) between the strains among the different genotypes. In addition, we constructed a minimum spanning tree for clustering analysis of the VNTR profiles. Our findings showed that eight MIRU–VNTR loci displayed disparities in h values of ≥0.2 between the Beijing genotype and non-Beijing genotype isolates. To efficiently discriminate Beijing and non-Beijing genotypes, an optimal VNTR set was established by adding loci with APDs ranging from 87.2% to 58.8%, resulting in the construction of a nine-locus set. We also found that QUB11a is a powerful locus for separating ST10s (including ST10, STF and STCH1) and ST22s (including ST22 and ST8) strains, whereas a combination of QUB11a, QUB4156, QUB18, Mtub21 and QUB26 could efficiently discriminate Beijing sublineages. Our findings suggested that two nine-locus sets were not only efficient for distinguishing the Beijing genotype from non-Beijing genotype strains, but were also suitable for sublineage genotyping with different discriminatory powers. These results indicate that APD represents a quantitative and efficient approach for selecting MIRU–VNTR loci to discriminate between divergent M. tuberculosis sublineages. PMID:28745309

  12. Neutrophil gelatinase-associated lipocalin (NGAL) and matrix metalloproteinases as novel stress markers in children and young adults on chronic dialysis.

    Science.gov (United States)

    Musiał, Kinga; Zwolińska, Danuta

    2011-03-01

    Phenomena related to chronic kidney disease, such as atherosclerosis, aggravate with the introduction of dialysis. Matrix metalloproteinases (MMP) and factors modifying their activity, such as their tissue inhibitors (TIMP) or neutrophil gelatinase-associated lipocalin (NGAL), take part in the matrix turnover and the endothelial damage characteristic for atherogenesis. However, there are no data on the associations between these parameters and other known pro-atherogenic factors, or on the impact of various dialysis modalities on them. The aim of our study was to assess the serum concentrations of NGAL, MMP-7, MMP-9, and TIMP-1, as well as their correlations with human heat shock proteins (Hsp90α, anti-Hsp60), endothelial dysfunction (sE-selectin), and inflammation (hsCRP) in pediatric patients chronically dialyzed. Twenty-two children on automated peritoneal dialysis (APD), 17 patients on hemodialysis (HD) and 24 controls were examined. The serum concentrations of NGAL, MMP-7, MMP-9, TIMP-1, Hsp90α, anti-Hsp60, and sE-selectin were assessed by enzyme-linked immunosorbent assay (ELISA). The median values of NGAL, MMP-7, MMP-9, TIMP-1, and MMP-9/NGAL ratio were significantly elevated in all dialyzed children vs. controls and were higher in HD than in APD. The values of MMP-9/TIMP-1 and MMP-7/TIMP-1 ratios in the HD subjects were lower than those in the APD children. Hsp90α and anti-Hsp60 predicted the values of NGAL, MMPs, and TIMP-1. Additionally, sE-selectin was a predictor of NGAL levels, whereas NGAL predicted the MMP and TIMP-1 concentrations. The increased concentrations of examined parameters indicate the dysfunction of MMP/TIMP/NGAL system in the dialyzed children, more pronounced on hemodialysis. The discrepancies between dialysis modalities and correlations with heat shock proteins (HSPs) suggest that NGAL may be considered a novel stress protein, whereas MMP-7, MMP-9, and TIMP-1 may be regarded as indicators of stress response in the pediatric

  13. Stability or instability in avoidant personality disorder:Mode fluctuations within schema therapy sessions.

    Science.gov (United States)

    Peled, Ofer; Bar-Kalifa, Eran; Rafaeli, Eshkol

    2017-12-01

    Avoidant personality disorder (APD) is among the most prevalent personality disorders, but has received relatively little empirical attention. This study aims to characterize the frequency, intensity, and fluctuation patterns seen in the modes (self-states) of APD clients over the course of schema therapy (ST), a psychotherapy approach developed especially for personality disorders. The newly-developed client mode rating scale (CMRS) was used to code every 5-min segment (n = 645) of 60 ST sessions. Each segment was coded by two independent raters, achieving adequate reliability. The avoidant/detached mode was present in 74% of therapy segments and was the most intense and unstable mode; the vulnerable child mode was present in 58% of segments and was the second most intense and unstable mode; the dysfunctional parent mode was present in 40% of segments, and was the third most intense and unstable mode; the over-compensator, compliant-surrenderer, and healthy adult modes were present in around 33% of segments, but the healthy adult mode was significantly more stable than all others. Although 645 segments were coded, they were drawn from only 15 APD clients with no control group. Further studies are needed to established specificity to APD. This study demonstrates the utility of the mode concept as a lexicon for capturing personality states and their instability. It highlights the use of in-session segment-by-segment ratings to assess client change within psychotherapy. Although DSM5 fails to address instability as a criterion for avoidant personality disorder, the APD clients in the current study were characterized by considerable mode instability. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Sex differences in repolarization and slow delayed rectifier potassium current and their regulation by sympathetic stimulation in rabbits.

    Science.gov (United States)

    Zhu, Yujie; Ai, Xun; Oster, Robert A; Bers, Donald M; Pogwizd, Steven M

    2013-06-01

    Slow delayed rectifier potassium current (IKs) is important in action potential (AP) repolarization and repolarization reserve. We tested the hypothesis that there are sex-specific differences in IKs, AP, and their regulation by β-adrenergic receptors (β-AR's) using whole-cell patch-clamp. AP duration (APD90) was significantly longer in control female (F) than in control male (M) myocytes. Isoproterenol (ISO, 500 nM) shortened APD90 comparably in M and F, and was largely reversed by β1-AR blocker CGP 20712A (CGP, 300 nM). Inhibition of IKs with chromanol 293B (10 μM) resulted in less APD prolongation in F at baseline (3.0 vs 8.9 %, p < 0.05 vs M) and even in the presence of ISO (5.4 vs 20.9 %, p < 0.05). This suggests that much of the ISO-induced APD abbreviation in F is independent of IKs. In F, baseline IKs was 42 % less and was more weakly activated by ISO (19 vs 68 % in M, p < 0.01). ISO enhancement of IKs was comparably attenuated by CGP in M and F. After ovariectomy, IKs in F had greater enhancement by ISO (72 %), now comparable to control M. After orchiectomy, IKs in M was only slightly enhanced by ISO (23 %), comparable to control F. Pretreatment with thapsigargin (to block SR Ca release) had bigger impact on ISO-induced APD shortening in F than that in M (p < 0.01). In conclusion, we found that there are sex differences in IKs, AP, and their regulation by β-AR's that are modulated by sex hormones, suggesting the potential for sex-specific antiarrhythmic therapy.

  15. New Concept of the Biosynthesis of 4-Alkyl-L-proline Precursors of Lincomycin, Hormaomycin and Pyrrolobenzodiazepines: Could a γ-Glutamyltransferase Cleave the C-C Bond?

    Directory of Open Access Journals (Sweden)

    Petra eJiraskova

    2016-03-01

    Full Text Available Structurally different and functionally diverse natural compounds – antitumour agents pyrrolo[1,4]benzodiazepines, bacterial hormone hormaomycin and lincosamide antibiotic lincomycin – share a common building unit, 4-alkyl-L-proline derivative (APD. APDs arise from L-tyrosine through a special biosynthetic pathway. Its generally accepted scheme, however, did not comply with current state of knowledge. Based on gene inactivation experiments and in vitro functional tests with recombinant enzymes, we designed a new APD biosynthetic scheme for the model of lincomycin biosynthesis. In the new scheme at least one characteristic in each of five final biosynthetic steps has been changed: the order of reactions, assignment of enzymes and/or reaction mechanisms. First, we demonstrate that LmbW methylates a different substrate than previously assumed. Second, we propose a unique reaction mechanism for the next step, in which a putative γ-glutamyltransferase LmbA indirectly cleaves off the oxalyl residue by transient attachment of glutamate to LmbW product. This unprecedented mechanism would represent the first example of the C-C bond cleavage catalyzed by a γ-glutamyltransferase, i.e., an enzyme that appears unsuitable for such activity. Finally, the inactivation experiments show that LmbX is an isomerase indicating that it transforms its substrate into a compound suitable for reduction by LmbY, thereby facilitating its subsequent complete conversion to APD 4-propyl-L-proline. Elucidation of the APD biosynthesis has long time resisted mainly due to the apparent absence of relevant C-C bond cleaving enzymatic activity. Our proposal aims to unblock this situation not only for lincomycin biosynthesis, but generally for all above mentioned groups of bioactive natural products with biotechnological potential.

  16. The practices, challenges and recommendations of South African audiologists regarding managing children with auditory processing disorders

    Directory of Open Access Journals (Sweden)

    Claire Fouché-Copley

    2016-06-01

    Full Text Available Audiologists managing children with auditory processing disorders (APD encounter challenges that include conflicting definitions, several classification profiles, problems with differential diagnosis and a lack of standardised guidelines. The heterogeneity of the disorder and its concomitant childhood disorders makes diagnosis difficult. Linguistic and cultural issues are additional challenges faced by South African audiologists. The study aimed to describe the practices, challenges and recommendations of South African audiologists managing children with APD. A quantitative, non-experimental descriptive survey was used to obtain data from 156 audiologists registered with the Health Professions of South Africa. Findings revealed that 67% screened for APD, 42% assessed while 43% provided intervention. A variety of screening and assessment procedures were being administered, with no standard test battery identified. A range of intervention strategies being used are discussed. When the relationship between the number of years of experience and the audiologists’ level of preparedness to practice in the field of APD was compared, a statistically significant difference (p = 0.049 was seen in that participants with more than 10 years of experience were more prepared to practice in this area. Those participants having qualified as speech-language therapists and audiologists were significantly more prepared (p = 0.03 to practice than the audiologists who comprised the sample. Challenges experienced by the participants included the lack of linguistically and culturally appropriate screening and assessment tools and limited normative data. Recommendations included reviewing the undergraduate audiology training programmes, reinstituting the South African APD Taskforce, developing linguistically and culturally appropriate normative data, creating awareness among educators and involving them in the multidisciplinary team. Keywords: Screening; assessment

  17. Cardiac action potential repolarization revisited: early repolarization shows all-or-none behaviour.

    Science.gov (United States)

    Trenor, Beatriz; Cardona, Karen; Saiz, Javier; Noble, Denis; Giles, Wayne

    2017-11-01

    In healthy mammalian hearts the action potential (AP) waveform initiates and modulates each contraction, or heartbeat. As a result, AP height and duration are key physiological variables. In addition, rate-dependent changes in ventricular AP duration (APD), and variations in APD at a fixed heart rate are both reliable biomarkers of electrophysiological stability. Present guidelines for the likelihood that candidate drugs will increase arrhythmias rely on small changes in APD and Q-T intervals as criteria for safety pharmacology decisions. However, both of these measurements correspond to the final repolarization of the AP. Emerging clinical evidence draws attention to the early repolarization phase of the action potential (and the J-wave of the ECG) as an additional important biomarker for arrhythmogenesis. Here we provide a mechanistic background to this early repolarization syndrome by summarizing the evidence that both the initial depolarization and repolarization phases of the cardiac action potential can exhibit distinct time- and voltage-dependent thresholds, and also demonstrating that both can show regenerative all-or-none behaviour. An important consequence of this is that not all of the dynamics of action potential repolarization in human ventricle can be captured by data from single myocytes when these results are expressed as 'repolarization reserve'. For example, the complex pattern of cell-to-cell current flow that is responsible for AP conduction (propagation) within the mammalian myocardium can change APD and the Q-T interval of the electrocardiogram alter APD stability, and modulate responsiveness to pharmacological agents (such as Class III anti-arrhythmic drugs). © 2017 The Authors. The Journal of Physiology © 2017 The Physiological Society.

  18. Self-esteem in patients with borderline and avoidant personality disorders.

    Science.gov (United States)

    Lynum, L I; Wilberg, T; Karterud, S

    2008-10-01

    This study compared self-esteem in patients with avoidant personality disorder (APD) and borderline personality disorder (BPD). Patients diagnosed with one or more personality disorders answered the questionnaire Index of Self Esteem as part of a comprehensive evaluation within the setting of a treatment trial. Our hypotheses were that (1) both patients with APD and patients with BPD would report low levels of self-esteem, (2) patients with APD would report lower self-esteem than patients with BPD. We further expected that (3) patients with higher levels of depression would report lower levels of self-esteem, but that (4) both borderline and avoidant personality pathology would contribute to explained variance in self-esteem beyond what would be accounted for by depression. All of our hypotheses were supported. The results from our study showed a significant difference in self-esteem level between the two personality disorders, patients with APD reporting lower self-esteem than patients with BPD. Subjects with both disorders were measured to have self-esteem levels within the range that presumes clinical problems. Self-esteem represents an important quality of subjective experience of the self, and the study of self-esteem in PDs can offer new and important knowledge of PDs as self-pathology.

  19. Photon-counting monolithic avalanche photodiode arrays for the super collider

    International Nuclear Information System (INIS)

    Ishaque, A.N.; Castleberry, D.E.; Rougeot, H.M.

    1994-01-01

    In fiber tracking, calorimetry, and other high energy and nuclear physics experiments, the need arises to detect an optical signal consisting of a few photons (in some cases a single photoelectron) with a detector insensitive to magnetic fields. Previous attempts to detect a single photoelectron have involved avalanche photodiodes (APDs) operated in the Geiger mode, the visible light photon counter, and a photomultiplier tube with an APD as the anode. In this paper it is demonstrated that silicon APDs, biased below the breakdown voltage, can be used to detect a signal of a few photons with conventional pulse counting circuitry at room temperature. Moderate cooling, it is further argued, could make it possible to detect a single photoelectron. Monolithic arrays of silicon avalanche photodiodes fabricated by Radiation Monitoring Devices, Inc. (RMD) were evaluated for possible use in the Super Collider detector systems. Measurements on 3 element x 3 element (2 mm pitch) APD arrays, using pulse counting circuitry with a charge sensitive amplifier (CSA) and a Gaussian filter, are reported and found to conform to a simple noise model. The model is used to obtain the optimal operating point. Experimental results are described in Section II, modeling results in Section III, and the conclusions are summarized in Section IV

  20. Towards Identify Selective Antibacterial Peptides Based on Abstracts Meaning

    Directory of Open Access Journals (Sweden)

    Liliana I. Barbosa-Santillán

    2016-01-01

    Full Text Available We present an Identify Selective Antibacterial Peptides (ISAP approach based on abstracts meaning. Laboratories and researchers have significantly increased the report of their discoveries related to antibacterial peptides in primary publications. It is important to find antibacterial peptides that have been reported in primary publications because they can produce antibiotics of different generations that attack and destroy the bacteria. Unfortunately, researchers used heterogeneous forms of natural language to describe their discoveries (sometimes without the sequence of the peptides. Thus, we propose that learning the words meaning instead of the antibacterial peptides sequence is possible to identify and predict antibacterial peptides reported in the PubMed engine. The ISAP approach consists of two stages: training and discovering. ISAP founds that the 35% of the abstracts sample had antibacterial peptides and we tested in the updated Antimicrobial Peptide Database 2 (APD2. ISAP predicted that 45% of the abstracts had antibacterial peptides. That is, ISAP found that 810 antibacterial peptides were not classified like that, so they are not reported in APD2. As a result, this new search tool would complement the APD2 with a set of peptides that are candidates to be antibacterial. Finally, 20% of the abstracts were not semantic related to APD2.

  1. Oxidative shift in tissue redox potential increases beat-to-beat variability of action potential duration.

    Science.gov (United States)

    Kistamás, Kornél; Hegyi, Bence; Váczi, Krisztina; Horváth, Balázs; Bányász, Tamás; Magyar, János; Szentandrássy, Norbert; Nánási, Péter P

    2015-07-01

    Profound changes in tissue redox potential occur in the heart under conditions of oxidative stress frequently associated with cardiac arrhythmias. Since beat-to-beat variability (short term variability, SV) of action potential duration (APD) is a good indicator of arrhythmia incidence, the aim of this work was to study the influence of redox changes on SV in isolated canine ventricular cardiomyocytes using a conventional microelectrode technique. The redox potential was shifted toward a reduced state using a reductive cocktail (containing dithiothreitol, glutathione, and ascorbic acid) while oxidative changes were initiated by superfusion with H2O2. Redox effects were evaluated as changes in "relative SV" determined by comparing SV changes with the concomitant APD changes. Exposure of myocytes to the reductive cocktail decreased SV significantly without any detectable effect on APD. Application of H2O2 increased both SV and APD, but the enhancement of SV was the greater, so relative SV increased. Longer exposure to H2O2 resulted in the development of early afterdepolarizations accompanied by tremendously increased SV. Pretreatment with the reductive cocktail prevented both elevation in relative SV and the development of afterdepolarizations. The results suggest that the increased beat-to-beat variability during an oxidative stress contributes to the generation of cardiac arrhythmias.

  2. Self-esteem and other-esteem in college students with borderline and avoidant personality disorder features: An experimental vignette study

    OpenAIRE

    Bowles, David P.; Armitage, Chris J.; Drabble, Jennifer; Meyer, Björn

    2013-01-01

    An experimental study investigated self- and other-esteem responses to either fully supportive or less supportive interpersonal feedback in college students with avoidant and borderline personality disorder features (APD and BPD, respectively). Disturbances in self-esteem and in evaluations of others are central to definitions of both APD and BPD, but the extent to which such interpersonal appraisals are responsive to contextual features, such as evaluative feedback from others, is not yet cl...

  3. Studies of relative gain and timing response of fine-mesh photomultiplier tubes in high magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Sulkosky, V.; Allison, L.; Barber, C.; Cao, T.; Ilieva, Y.; Jin, K.; Kalicy, G.; Park, K.; Ton, N.; Zheng, X.

    2016-08-01

    We investigated the use of Hamamatsu fine-mesh photomultiplier tube assemblies H6152-70 and H6614-70 with regards to their gain and timing resolution in magnetic fields up to 1.9 T. Our results show that the H6614-70 assembly can operate reliably in magnetic fields exceeding 1.5 T, while preserving a reasonable timing resolution even with a gain reduction of a factor of ~100. The reduction of the relative gain of the H6152-70 is similar to the H6614-70's near 1.5 T, but its timing resolution worsens considerably at this high field.

  4. On a Three-Channel Cosmic Ray Detector based on Aluminum Blocks

    Science.gov (United States)

    Arceo, L.; Félix, J.

    2017-10-01

    There are many general purpose cosmic ray detectors based on plastic scintillators and electronic boards from the market. This is a new cosmic ray detector designed on three 2.54 cm × 5.08 cm × 20.32 cm Aluminum blocks in stack arrangement, and three Hamamatsu S12572-100P photodiodes. The photodiode board, the passive electronic board, and the discriminator board are own designed. The electronic signals are stored with a CompactRIO -cRIO- by National Instruments. It is presented the design, the construction, the data acquisition system algorithm, and the preliminary physical results.

  5. Matrix metalloproteinases and soluble Fas/FasL system as novel regulators of apoptosis in children and young adults on chronic dialysis.

    Science.gov (United States)

    Musiał, Kinga; Zwolińska, Danuta

    2011-07-01

    The system of membrane receptor Fas and its ligand FasL compose one of the main pathways triggering apoptosis. However, the role of their soluble forms has not been clarified yet. Although sFasL can be converted from the membrane-bound form by matrix metalloproteinases (MMPs), there are no data on relations between sFas/sFasL, MMPs and their tissue inhibitors (TIMPs) in patients on chronic dialysis--neither children nor adults. The aim of our study was to evaluate serum concentrations of sFas, sFasL, and their potential regulators (MMP-2, MMP-7, MMP-9, TIMP-1, TIMP-2), in children and young adults chronically dialyzed. Twenty-two children on automated peritoneal dialysis (APD), 19 patients on hemodialysis (HD) and 30 controls were examined. Serum concentrations of sFas, sFasL, MMPs and TIMPs were assessed by ELISA. Median values of sFas, sFasL, sFas/sFasL ratio, MMP-2, MMP-7, MMP-9, TIMP-1 and TIMP-2 were significantly elevated in all dialyzed patients vs. controls, the highest values being observed in subjects on HD. A single HD session caused the decrease in values of all parameters to the levels below those seen in children on APD. Regression analysis revealed that MMP-7 and TIMP-1 were the best predictors of sFas and sFasL concentrations. Children and young adults on chronic dialysis are prone to sFas/sFasL system dysfunction, more pronounced in patients on hemodialysis. The correlations between sFas/sFasL and examined enzymes suggest that MMPs and TIMPs take part in the regulation of cell death in the pediatric population on chronic dialysis, triggering both anti- (sFas) and pro-apoptotic (sFasL) mechanisms.

  6. Ultraviolet Communication for Medical Applications

    Science.gov (United States)

    2012-06-01

    plasma discharges every 100 μs. The location of each discharge can be modulated to produce M-ary pulse position modulation (PPM), which encodes...counting compound semiconductor avalanche photodiodes (APD) are not yet commercially available, and no component manufacturer has stated that one is...short optical pulses with either an LED or Plasma-shell source, and receives scattered photons with a photon-counting PMT and data-logs the received

  7. Ballistic V50 Evaluation of TIMET Ti108

    Science.gov (United States)

    2018-02-01

    threat by 1 m/s. Future studies or adjustments to the chemistry of the Ti108 can be conducted to optimize ballistic performance. 15. SUBJECT TERMS...10 Fig. A-2 30-mm APDS overall back of plate .................................................... 10 List of Tables Table 1 Chemistry of Ti108...performance of different titanium alloys. Conventional Ti-6Al-4V is commonly used in aerospace frames and engine components, but has difficulty passing

  8. OGG1, MYH and MTH1 gene variants identified in gastric cancer ...

    Indian Academy of Sciences (India)

    Handayama, Hamamatsu, Shizuoka 431-3192, Japan. 2Department ... 1997; Farinati et al. 1998), induce inflammation in the stomach tissue. A con- ..... 1999; Chen et al. 2003 .... R., Nohmi T. and Yokota J. 2000 Adenine excisional repair func-.

  9. Karakteristik Dan Pergerakan Sebaran Penderita DBD Berdasarkan Geographic Information System Sebagai Bagian Sistem Informasi Surveilans di Kecamatan Karawang Barat Kabupaten Karawang Provinsi Jawa Barat

    Directory of Open Access Journals (Sweden)

    Doni Lasut

    2013-01-01

    Full Text Available Abstract. West Karawang is a part of Karawang District that have high case incidence in three years la ter. This research uses cross sectional study method was conducted that aimed to gain information of map ping DHF endemie region use GIS (Geographic Information sys­tems as a part of surveillance informatics system 2008. The special goals are to know the spatial aspect of the movement pattern , socio-demographic, larvae index, vector control programs, land systems and precipitation. The results of study are movement pattern of DHF in West Karawang is local, the socio-demographic of sex and marital status there are no special different, group of class age 15 - 44 years old (53,70%, non-formal working (81,48% is the h igh est. The socio-demographic of education Senior High School (38,89% is the highest too. Almost of The housing type permanent (94,44% is the dominant and the average wide building 50-100 meters (66,67% is the h igh est. House index larvae is 55,10% and container larvae index is 15,51 %. The vector control program of fogging in study area 70,37% is done and PSN program activity (81,48% this fact shown that there are many possibility for breeding place in this district. The Use of GIS helps to handle huge of data easily and much more information can be display clearly.Key Words : DHF, GIS, PSN, Fogging, Larvae Index

  10. Extended One-Generation Reproductive Toxicity Test in Rats Exposed to 3-Nitro-1,2,4 Triazol-5-One (NTO), October 2013-March 2014

    Science.gov (United States)

    2016-04-01

    Protection and Enhancement . http://www.apd.army.mil/pdffiles/r200_1.pdf. 2007. 3. DA, Regulation 40-5, Preventive Medicine. http://www.apd.army.mil...maturation. Any abnormalities of genital organs, such as persistent vaginal thread, hypospadia or cleft penis , will be noted. Body weight will be...consistency and precision is not greatly enhanced ” (ICH 2005). Examining all pups in each litter in the F1 generation will enhance the ability to detect effects

  11. Characterization of midwave infrared InSb avalanche photodiode

    Energy Technology Data Exchange (ETDEWEB)

    Abautret, J., E-mail: johan.abautret@ies.univ-montp2.fr; Evirgen, A. [Université Montpellier, IES, UMR 5214, F-34095 Montpellier (France); CNRS, IES, UMR 5214, F-34095 Montpellier (France); SOFRADIR, BP 21, 38113 Veurey-Voroize (France); Perez, J. P.; Christol, P. [Université Montpellier, IES, UMR 5214, F-34095 Montpellier (France); CNRS, IES, UMR 5214, F-34095 Montpellier (France); Rothman, J. [CEA-LETI, 17 rue des Martyrs, 38054 Grenoble Cedex 9 (France); Cordat, A. [SOFRADIR, BP 21, 38113 Veurey-Voroize (France)

    2015-06-28

    This paper focuses on the InSb material potential for the elaboration of Avalanche Photodiodes (APD) for high performance infrared imaging applications, both in passive or active mode. The first InSb electron-APD structure was grown by molecular beam epitaxy, processed and electrically characterized. The device performances are at the state of the art for the InSb epi-diode technology, with a dark current density J(−50 mV) = 32 nA/cm{sup 2} at 77 K. Then, a pure electron injection was performed, and an avalanche gain, increasing exponentially, was observed with a gain value near 3 at −4 V at 77 K. The Okuto–Crowell model was used to determine the electron ionization coefficient α(E) in InSb, and the InSb gain behavior is compared with the one of InAs and MCT APDs.

  12. Pro-arrhythmogenic effects of atrial fibrillation-induced electrical remodelling: insights from the three-dimensional virtual human atria.

    Science.gov (United States)

    Colman, Michael A; Aslanidi, Oleg V; Kharche, Sanjay; Boyett, Mark R; Garratt, Clifford; Hancox, Jules C; Zhang, Henggui

    2013-09-01

    Chronic atrial fibrillation (AF) is associated with structural and electrical remodelling in the atria, which are associated with a high recurrence of AF. Through biophysically detailed computer modelling, this study investigated mechanisms by which AF-induced electrical remodelling promotes and perpetuates AF. A family of Courtemanche-Ramirez-Nattel variant models of human atrial cell action potentials (APs), taking into account of intrinsic atrial electrophysiological properties, was modified to incorporate various experimental data sets on AF-induced changes of major ionic channel currents (ICaL, IKur, Ito, IK1, IKs, INaCa) and on intracellular Ca(2+) handling. The single cell models for control and AF-remodelled conditions were incorporated into multicellular three-dimensional (3D) atrial tissue models. Effects of the AF-induced electrical remodelling were quantified as the changes of AP profile, AP duration (APD) and its dispersion across the atria, and the vulnerability of atrial tissue to the initiation of re-entry. The dynamic behaviour of re-entrant excitation waves in the 3D models was characterised. In our simulations, AF-induced electrical remodelling abbreviated atrial APD non-uniformly across the atria; this resulted in relatively short APDs co-existing with marked regional differences in the APD at junctions of the crista terminalis/pectinate muscle, pulmonary veins/left atrium. As a result, the measured tissue vulnerability to re-entry initiation at these tissue junctions was increased. The AF-induced electrical remodelling also stabilized and accelerated re-entrant excitation waves, leading to rapid and sustained re-entry. Under the AF-remodelled condition, re-entrant scroll waves in the 3D model degenerated into persistent and erratic wavelets, leading to fibrillation. In conclusion, realistic 3D atrial tissue models indicate that AF-induced electrical remodelling produces regionally heterogeneous and shortened APD; these respectively facilitate

  13. Glucose absorption in acute peritoneal dialysis.

    Science.gov (United States)

    Podel, J; Hodelin-Wetzel, R; Saha, D C; Burns, G

    2000-04-01

    During acute peritoneal dialysis (APD), it is known that glucose found in the dialysate solution contributes to the provision of significant calories. It has been well documented in continuous ambulatory peritoneal dialysis (CAPD) that glucose absorption occurs. In APD, however, it remains unclear how much glucose absorption actually does occur. Therefore, the purpose of this study was to determine whether it is appropriate to use the formula used to calculate glucose absorption in CAPD (Grodstein et al) among patients undergoing APD. Actual measurements of glucose absorption (Method I) were calculated in 9 patients undergoing APD treatment for >24 hours who were admitted to the intensive care unit. Glucose absorption using the Grodstein et al formula (Method II) was also determined and compared with the results of actual measurements. The data was then further analyzed based on the factors that influence glucose absorption, specifically dwell time and concentration. The mean total amount of glucose absorbed was 43% +/- 15%. However, when dwell time and concentration were further examined, significant differences were noted. Method I showed a cumulative increase over time. Method II showed that absorption was fixed. This suggests that with the variation in dwell time commonly seen in the acute care setting, the use of Method II may not be accurate. In each of the 2 methods, a significant difference in glucose absorption was noted when comparing the use of 1.5% and 4.25% dialysate concentrations. The established formula designed for CAPD should not be used for calculating glucose absorption in patients receiving APD because variation in dwell time and concentration should be taken into account. Because of the time constraints and staffing required to calculate each exchange individually, combined with the results of the study, we recommend the use of the percentage estimate of 40% to 50%.

  14. Differential expression of hERG1 channel isoforms reproduces properties of native I(Kr and modulates cardiac action potential characteristics.

    Directory of Open Access Journals (Sweden)

    Anders Peter Larsen

    Full Text Available BACKGROUND: The repolarizing cardiac rapid delayed rectifier current, I(Kr, is composed of ERG1 channels. It has been suggested that two isoforms of the ERG1 protein, ERG1a and ERG1b, both contribute to I(Kr. Marked heterogeneity in the kinetic properties of native I(Kr has been described. We hypothesized that the heterogeneity of native I(Kr can be reproduced by differential expression of ERG1a and ERG1b isoforms. Furthermore, the functional consequences of differential expression of ERG1 isoforms were explored as a potential mechanism underlying native heterogeneity of action potential duration (APD and restitution. METHODOLOGY/PRINCIPAL FINDINGS: The results show that the heterogeneity of native I(Kr can be reproduced in heterologous expression systems by differential expression of ERG1a and ERG1b isoforms. Characterization of the macroscopic kinetics of ERG1 currents demonstrated that these were dependent on the relative abundance of ERG1a and ERG1b. Furthermore, we used a computational model of the ventricular cardiomyocyte to show that both APD and the slope of the restitution curve may be modulated by varying the relative abundance of ERG1a and ERG1b. As the relative abundance of ERG1b was increased, APD was gradually shortened and the slope of the restitution curve was decreased. CONCLUSIONS/SIGNIFICANCE: Our results show that differential expression of ERG1 isoforms may explain regional heterogeneity of I(Kr kinetics. The data demonstrate that subunit dependent changes in channel kinetics are important for the functional properties of ERG1 currents and hence I(Kr. Importantly, our results suggest that regional differences in the relative abundance of ERG1 isoforms may represent a potential mechanism underlying the heterogeneity of both APD and APD restitution observed in mammalian hearts.

  15. Integrated three-dimensional optical MEMS for chip-based fluorescence detection

    Science.gov (United States)

    Hung, Kuo-Yung; Tseng, Fan-Gang; Khoo, Hwa-Seng

    2009-04-01

    This paper presents a novel fluorescence sensing chip for parallel protein microarray detection in the context of a 3-in-1 protein chip system. This portable microchip consists of a monolithic integration of CMOS-based avalanche photo diodes (APDs) combined with a polymer micro-lens, a set of three-dimensional (3D) inclined mirrors for separating adjacent light signals and a low-noise transformer-free dc-dc boost mini-circuit to power the APDs (ripple below 1.28 mV, 0-5 V input, 142 V and 12 mA output). We fabricated our APDs using the planar CMOS process so as to facilitate the post-CMOS integration of optical MEMS components such as the lenses. The APD arrays were arranged in unique circular patterns appropriate for detecting the specific fluorescently labelled protein spots in our study. The array-type APDs were designed so as to compensate for any alignment error as detected by a positional error signal algorithm. The condenser lens was used as a structure for light collection to enhance the fluorescent signals by about 25%. This element also helped to reduce the light loss due to surface absorption. We fabricated an inclined mirror to separate two adjacent fluorescent signals from different specimens. Excitation using evanescent waves helped reduce the interference of the excitation light source. This approach also reduced the number of required optical lenses and minimized the complexity of the structural design. We achieved detection floors for anti-rabbit IgG and Cy5 fluorescent dye as low as 0.5 ng/µl (~3.268 nM). We argue that the intrinsic nature of point-to-point and batch-detection methods as showcased in our chip offers advantages over the serial-scanning approach used in traditional scanner systems. In addition, our system is low cost and lightweight.

  16. Acid-base profile and predictors of metabolic acidosis in patients undergoing peritoneal dialysis with lactate- and bicarbonate-buffered peritoneal dialysis solutions.

    Science.gov (United States)

    Fourtounas, Costas; Savidaki, Eirini; Roumelioti, Marilena; Dousdampanis, Periklis; Hardalias, Andreas; Kalliakmani, Pantelitsa; Papachristou, Evangelos; Drakopoulos, Anastasios; Goumenos, Dimitrios S; Vlachojannis, Jannis G

    2006-01-01

    Metabolic acidosis correction is one of the goals of renal replacement therapy. Correction of acidosis in peritoneal dialysis (PD) may be affected by PD modalities such as automated PD (APD) or by new solutions containing a combination of bicarbonate and lactate as a buffer [bicarbonate continuous ambulatory PD (CAPD)]. The aim of the present study was to examine the acid-base status of our PD population and to compare the effects of APD, lactate CAPD, and bicarbonate CAPD on serum bicarbonate levels. We studied 35 stable patients undergoing APD (n = 15), lactate-buffered (35 mEq/L) CAPD (n = 14), and bicarbonate/lactate-buffered CAPD (n = 6) for 48.5 +/- 38.1 months. Most of our patients had serum bicarbonate levels in the normal range. In 3 patients (8%), HCO3 was below 22 mEq/L, and in 8 patients (22%; APD = 2, lactate CAPD = 2, bicarbonate CAPD = 4), HCO3 was above 28 mEq/L. We found no statistically significant correlations between HCO3 serum levels and PD prescription, peritoneal membrane characteristics, or intake of calcium carbonate and sevelamer hydrochloride. Patients on bicarbonate CAPD had higher HCO3 serum levels, but this difference disappeared when corrections for duration of dialysis, residual urine volume, and PD adequacy indices were applied. In the studied PD population, adequate correction of metabolic acidosis was achieved, as reflected in serum bicarbonate levels. We observed no difference in serum bicarbonate levels between APD and lactate CAPD patients. The new bicarbonate-buffered PD solutions are more biocompatible and can result in higher serum bicarbonate levels. However, a significant number of PD patients on bicarbonate-buffered solutions may become alkalotic. The clinical significance of these results needs further examination in prospective studies.

  17. Intelligibility of degraded speech and the relationship between symptoms of inattention, hyperactivity/impulsivity and language impairment in children with suspected auditory processing disorder.

    Science.gov (United States)

    Ahmmed, Ansar Uddin

    2017-10-01

    To compare the sensitivity and specificity of Auditory Figure Ground sub-tests of the SCAN-3 battery, using signal to noise ratio (SNR) of +8 dB (AFG+8) and 0 dB (AFG0), in identifying auditory processing disorder (APD). A secondary objective was to evaluate any difference in auditory processing (AP) between children with symptoms of inattention versus combined sub-types of Attention Deficit Hyperactivity Disorder (ADHD). Data from 201 children, aged 6 to 16 years (mean: 10 years 6 months, SD: 2 years 8 months), who were assessed for suspected APD were reviewed retrospectively. The outcomes of the SCAN-3 APD test battery, Swanson Nolan and Pelham-IV parental rating (SNAP-IV) and Children's Communication Checklist-2 (CCC-2) were analysed. AFG0 had a sensitivity of 56.3% and specificity of 100% in identifying children performing poorly in at least two of six SCAN-3 sub-tests or one of the two questionnaires, in contrast to 42.1% and 80% respectively for AFG+8. Impaired AP was mostly associated with symptoms of ADHD and /or language impairment (LI). LI was present in 92.9% of children with ADHD symptoms. Children with symptoms of combined ADHD plus LI performed significantly poorly (p Speech in noise tests using SNR of 0 dB is better than +8 dB in assessing APD. The better FW performance of the inattention ADHD plus LI group can be speculated to be related to known difference in activity in a neural network between different sub-types of ADHD. The findings of the study and existing literature suggest that neural networks connecting the cerebral hemispheres, basal ganglia and cerebellum are involved in APD, ADHD and LI. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. SiPM Gain Stabilization Studies for Adaptive Power Supply

    CERN Document Server

    AUTHOR|(CDS)2074257; Zalieckas, Justas; Cvach, Jaroslav; Kvasnicka, Jiri; Polak, Ivo

    2016-01-01

    We present herein gain stabilization studies of SiPMs using a climate chamber at CERN. We present results for four detectors not tested before, three from Hamamatsu and one from KETEK. Two of the Hamamatsu SiPMs are novel sensors with trenches that reduce cross talk. We use an improved readout system with a digital oscilloscope controlled with a dedicated LabView program. We improved and automized the analysis to deal with large datasets. We have measured the gain-versus-bias-voltage dependence at fixed temperature and gain-versus-temperature dependence at fixed bias voltage to determine the bias voltage dependence on temperature $V(T)$ for stable gain. We show that the gain remains stable to better than $\\pm 0.5\\%$ in the $20^\\circ \\rm C - 30^\\circ C$ temperature range if the bias voltage is properly adjusted with temperature.

  19. Performance evaluation of LaBr3: Ce scintillator

    International Nuclear Information System (INIS)

    Xie Ming; Lin Li; Liu Shihao; Xiao Peng; Xie Qingguo

    2012-01-01

    The cerium doped lanthanum bromide crystal (LaBr 3 : Ce) is a new kind of scintillator with many advantages such as good energy resolution, high light output, short decay time, good proportionality response. These properties make the LaBr 3 : Ce attractive substantial interest to use in the radiation detection. The energy resolution were investigated with Φ25 × 25 mm LaBr 3 : Ce coupled to a Hamamatsu R8900 photomultiplier tube. Energy resolution of 3.6% (FWHM) have been achieved for 511 keV photons ( 18 F source) at room temperature. Decay time constant of 20 ns have been acquired with a Hamamatsu fast-time-response R9800 photomultiplier tube. The results approve the excellent characterizations of LaBr 3 : Ce and imply its enormous potentiality in the radiation detectors of gamma-ray spectroscopy and PET. (authors)

  20. Energy resolution measurements of LaBr3:Ce scintillating crystals with an ultra-high quantum efficiency photomultiplier tube

    International Nuclear Information System (INIS)

    Pani, R.; Cinti, M.N.; Scafe, R.; Pellegrini, R.; Vittorini, F.; Bennati, P.; Ridolfi, S.; Lo Meo, S.; Mattioli, M.; Baldazzi, G.; Pisacane, F.; Navarria, F.; Moschini, G.; Boccaccio, P.; Orsolini Cencelli, V.; Sacco, D.

    2009-01-01

    The performance of the new prototype of high quantum efficiency PMT (43% at 380 nm), Hamamatsu R7600U-200, was studied coupled to a LaBr 3 :Ce crystal with the size of o12.5 mmx12.5 mm. The energy resolution results were compared with ones from two PMTs, Hamamatsu R7600U and R6231MOD, with 22% and 30% quantum efficiency (QE), respectively. Moreover, the photodetectors were equipped with tapered and un-tapered voltage dividers to study the non-linearity effects on pulse height distribution, due to very high peak currents induced in the PMT by the fast and intense light pulse of LaBr 3 :Ce. The results show an energy resolution improvement with UBA PMT of about 20%, in the energy range of 80-662 keV, with respect to the BA one.

  1. Lowering the radioactivity of the photomultiplier tubes for the XENON1T dark matter experiment

    Energy Technology Data Exchange (ETDEWEB)

    Aprile, E.; Contreras, H.; Goetzke, L.W.; Fernandez, A.J.M.; Messina, M.; Plante, G.; Rizzo, A. [Columbia University, Physics Department, New York, NY (United States); Agostini, F. [INFN-Laboratori Nazionali del Gran Sasso (Italy); Gran Sasso Science Institute, L' Aquila (Italy); Bologna Univ., Department of Physics and Astrophysics, Bologna (Italy); INFN, Bologna (Italy); Alfonsi, M. [Nikhef and the University of Amsterdam, Amsterdam (Netherlands); Johannes Gutenberg-Universitaet Mainz, Institut fuer Physik and Exzellenzcluster PRISMA, Mainz (Germany); Arazi, L.; Budnik, R.; Duchovni, E.; Gross, E.; Itay, R.; Landsman, H.; Lellouch, D.; Levinson, L.; Priel, N.; Vitells, O. [Weizmann Institute of Science, Department of Particle Physics and Astrophysics, Rehovot (Israel); Arisaka, K.; Lyashenko, A.; Meng, Y.; Pantic, E.; Teymourian, A.; Wang, H. [University of California, Physics and Astronomy Department, Los Angeles, CA (United States); Arneodo, F.; Di Giovanni, A. [New York University Abu Dhabi, Abu Dhabi (United Arab Emirates); Auger, M.; Barrow, P.; Baudis, L.; Behrens, A.; Galloway, M.; Kessler, G.; Kish, A.; Mayani, D.; Pakarha, P.; Piastra, F. [University of Zurich, Physik-Institut, Zurich (Switzerland); Balan, C.; Cardoso, J.M.R.; Lopes, J.A.M.; Santos, J.M.F. dos [University of Coimbra, Department of Physics, Coimbra (Portugal); Bauermeister, B.; Fattori, S.; Geis, C.; Grignon, C.; Oberlack, U.; Schindler, S. [Johannes Gutenberg-Universitaet Mainz, Institut fuer Physik and Exzellenzcluster PRISMA, Mainz (Germany); Beltrame, P. [Weizmann Institute of Science, Department of Particle Physics and Astrophysics, Rehovot (Israel); University of Edinburgh, Edinburgh (United Kingdom); Brown, A.; Lang, R.F.; Macmullin, S.; Pienaar, J.; Reichard, S.; Reuter, C. [Purdue University, Department of Physics and Astronomy, West Lafayette, IN (United States); Brown, E.; Levy, C. [Rensselaer Polytechnic Institute, Department of Physics, Applied Physics and Astronomy, Troy, NY (United States); Wilhelms-Universitaet Muenster, Institut fuer Kernphysik, Muenster (Germany); Bruenner, S.; Hampel, W.; Kaether, F.; Lindemann, S.; Lindner, M.; Undagoitia, T.M.; Rauch, L.; Schreiner, J.; Simgen, H.; Weber, M. [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); Bruno, G. [INFN-Laboratori Nazionali del Gran Sasso and Gran Sasso Science Institute, L' Aquila (Italy); Wilhelms-Universitaet Muenster, Institut fuer Kernphysik, Muenster (Germany); Buetikofer, L.; Coderre, D.; Schumann, M. [University of Bern, Albert Einstein Center for Fundamental Physics, Bern (Switzerland); Colijn, A.P.; Decowski, M.P.; Tiseni, A.; Tunnell, C. [Nikhef and the University of Amsterdam, Amsterdam (Netherlands); Cussonneau, J.P.; Le Calloch, M.; Masbou, J.; Lavina, L.S.; Thers, D. [Universite de Nantes, Subatech, Ecole des Mines de Nantes, CNRS/In2p3, Nantes (France); Ferella, A.D.; Fulgione, W.; Laubenstein, M. [INFN-Laboratori Nazionali del Gran Sasso and Gran Sasso Science Institute, L' Aquila (Italy); Fieguth, A.; Murra, M.; Rosendahl, S.; Weinheimer, C. [Wilhelms-Universitaet Muenster, Institut fuer Kernphysik, Muenster (Germany); Garbini, M.; Massoli, F.V.; Sartorelli, G.; Selvi, M. [Bologna Univ., Department of Physics and Astrophysics, Bologna (Italy); INFN, Bologna (Italy); Miguez, B.; Molinario, A.; Trinchero, G. [INFN-Torino and Osservatorio Astrofisico di Torino, Turin (Italy); Naganoma, J.; Shagin, P.; Wall, R. [Rice University, Department of Physics and Astronomy, Houston, TX (United States); Orrigo, S.E.A. [University of Coimbra, Department of Physics, Coimbra (Portugal); IFIC, CSIC-Universidad de Valencia, Valencia (Spain); Persiani, R. [Universite de Nantes, Subatech, Ecole des Mines de Nantes, CNRS/In2p3, Nantes (FR); Bologna Univ., Department of Physics and Astrophysics, Bologna (IT); INFN, Bologna (IT); Collaboration: XENON Collaboration

    2015-11-15

    The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410 has been developed by Hamamatsu for dark matter direct detection experiments using liquid xenon as the target material. We present the results from the joint effort between the XENON collaboration and the Hamamatsu company to produce a highly radio-pure photosensor (version R11410-21) for the XENON1T dark matter experiment. After introducing the photosensor and its components, we show the methods and results of the radioactive contamination measurements of the individual materials employed in the photomultiplier production. We then discuss the adopted strategies to reduce the radioactivity of the various PMT versions. Finally, we detail the results from screening 286 tubes with ultra-low background germanium detectors, as well as their implications for the expected electronic and nuclear recoil background of the XENON1T experiment. (orig.)

  2. Hybrid AlGaN-SiC Avalanche Photodiode for Deep-UV Photon Detection

    Science.gov (United States)

    Aslam, Shahid; Herrero, Federico A.; Sigwarth, John; Goldsman, Neil; Akturk, Akin

    2010-01-01

    The proposed device is capable of counting ultraviolet (UV) photons, is compatible for inclusion into space instruments, and has applications as deep- UV detectors for calibration systems, curing systems, and crack detection. The device is based on a Separate Absorption and Charge Multiplication (SACM) structure. It is based on aluminum gallium nitride (AlGaN) absorber on a silicon carbide APD (avalanche photodiode). The AlGaN layer absorbs incident UV photons and injects photogenerated carriers into an underlying SiC APD that is operated in Geiger mode and provides current multiplication via avalanche breakdown. The solid-state detector is capable of sensing 100-to-365-nanometer wavelength radiation at a flux level as low as 6 photons/pixel/s. Advantages include, visible-light blindness, operation in harsh environments (e.g., high temperatures), deep-UV detection response, high gain, and Geiger mode operation at low voltage. Furthermore, the device can also be designed in array formats, e.g., linear arrays or 2D arrays (micropixels inside a superpixel).

  3. Out of the frying pan, into the fire: mixed affective reactions to social proximity in borderline and avoidant personality disorders in daily life.

    Science.gov (United States)

    Gadassi, Reuma; Snir, Avigal; Berenson, Kathy; Downey, Geraldine; Rafaeli, Eshkol

    2014-08-01

    Social proximity typically helps individuals meet their belongingness needs, but several forms of psychopathology, including borderline and avoidant personality disorders (BPD and APD, respectively) are characterized by social difficulties. This experience-sampling study is one of the first to directly investigate the affective reactions of individuals with BPD and APD (compared with healthy controls [HC]) to social proximity in daily life. We examined both person-level and day-level reactions. At the person level, the rate of social proximity across the diary period was associated with diminished feelings of rejection, isolation, shame, and dissociation in the HC group. In contrast, it was not associated with any affective reaction in the BPD group, and was associated with decreased rejection and isolation on the one hand, but also with increased anxiety in the APD group. At the day level, we used multilevel regression to examine affective reactions when in social proximity. The HC group showed a consistent benefit when in social proximity. In contrast, both PD groups exhibited mixed affective reactions to social proximity; specifically, benefits (increased positive affect, decreased rejection, isolation, and dissociation) were interspersed with costs (increased shame for both PD groups; increased anger for BPD; increased anxiety for APD). The mixed reactions found in both PDs may contribute to the disturbed relationships of individuals with these disorders. (c) 2014 APA, all rights reserved.

  4. Association between language development and auditory processing disorders

    Directory of Open Access Journals (Sweden)

    Caroline Nunes Rocha-Muniz

    2014-06-01

    Full Text Available INTRODUCTION: It is crucial to understand the complex processing of acoustic stimuli along the auditory pathway ;comprehension of this complex processing can facilitate our understanding of the processes that underlie normal and altered human communication. AIM: To investigate the performance and lateralization effects on auditory processing assessment in children with specific language impairment (SLI, relating these findings to those obtained in children with auditory processing disorder (APD and typical development (TD. MATERIAL AND METHODS: Prospective study. Seventy-five children, aged 6-12 years, were separated in three groups: 25 children with SLI, 25 children with APD, and 25 children with TD. All went through the following tests: speech-in-noise test, Dichotic Digit test and Pitch Pattern Sequencing test. RESULTS: The effects of lateralization were observed only in the SLI group, with the left ear presenting much lower scores than those presented to the right ear. The inter-group analysis has shown that in all tests children from APD and SLI groups had significantly poorer performance compared to TD group. Moreover, SLI group presented worse results than APD group. CONCLUSION: This study has shown, in children with SLI, an inefficient processing of essential sound components and an effect of lateralization. These findings may indicate that neural processes (required for auditory processing are different between auditory processing and speech disorders.

  5. Mechanoelectric feedback does not contribute to the Frank-Starling relation in the rat and guinea pig heart

    Directory of Open Access Journals (Sweden)

    D Kelly

    2014-12-01

    Full Text Available Mechanoelectric feedback (MEF is the process by which mechanical forces on the myocardium can alter its electrical properties. The effect can be large enough to induce ectopic beats or fibrillation. However, the role of MEF at physiological levels of mechanical stress is not clear. We have investigated alteration in action potential morphology in rat and guinea pig ventricle and in rat atrial tissue at levels of stretch near the plateau of the Frank-Starling curve. Stretch of >100 mm.Hg End Diastolic Left Ventricular Pressure (EDLVP or rapidly applied stretch (EDLVP increased by 25 mm.Hg within 100 ms often triggered ectopic beats in isolated rat and guinea-pig hearts. However, ventricular epicardial monophasic action potentials (MAPs recorded during stretch to EDLVP up to 30 mm. Hg showed no consistent changes in action potential duration (at APD20, APD50 or APD80 in either species. MAP recording detected APD prolongation with very small concentrations of 4-AP (10 μM, confirming the discrimination of the recording technique. In isolated rat atrial strips, no changes in intracellular action potential morphology or membrane potential were seen when stretched to levels producing an optimum increase in contractility. We conclude that alteration in action potential morphology with stretch does not contribute to the Frank-Starling relation in ventricle of rat or guinea-pig isolated heart, or in rat atrial tissue.

  6. Inhibitory control and negative emotional processing in psychopathy and antisocial personality disorder.

    Science.gov (United States)

    Verona, Edelyn; Sprague, Jenessa; Sadeh, Naomi

    2012-05-01

    The field of personality disorders has had a long-standing interest in understanding interactions between emotion and inhibitory control, as well as neurophysiological indices of these processes. More work in particular is needed to clarify differential deficits in offenders with antisocial personality disorder (APD) who differ on psychopathic traits, as APD and psychopathy are considered separate, albeit related, syndromes. Evidence of distinct neurobiological processing in these disorders would have implications for etiology-based personality disorder taxonomies in future psychiatric classification systems. To inform this area of research, we recorded event-related brain potentials during an emotional-linguistic Go/No-Go task to examine modulation of negative emotional processing by inhibitory control in three groups: psychopathy (n = 14), APD (n = 16), and control (n = 15). In control offenders, inhibitory control demands (No-Go vs. Go) modulated frontal-P3 amplitude to negative emotional words, indicating appropriate prioritization of inhibition over emotional processing. In contrast, the psychopathic group showed blunted processing of negative emotional words regardless of inhibitory control demands, consistent with research on emotional deficits in psychopathy. Finally, the APD group demonstrated enhanced processing of negative emotion words in both Go and No-Go trials, suggesting a failure to modulate negative emotional processing when inhibitory control is required. Implications for emotion-cognition interactions and putative etiological processes in these personality disorders are discussed.

  7. Pixel multiplexing technique for real-time three-dimensional-imaging laser detection and ranging system using four linear-mode avalanche photodiodes

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Fan; Wang, Yuanqing, E-mail: yqwang@nju.edu.cn; Li, Fenfang [School of Electronic Science and Engineering, Nanjing University, Nanjing 210046 (China)

    2016-03-15

    The avalanche-photodiode-array (APD-array) laser detection and ranging (LADAR) system has been continually developed owing to its superiority of nonscanning, large field of view, high sensitivity, and high precision. However, how to achieve higher-efficient detection and better integration of the LADAR system for real-time three-dimensional (3D) imaging continues to be a problem. In this study, a novel LADAR system using four linear mode APDs (LmAPDs) is developed for high-efficient detection by adopting a modulation and multiplexing technique. Furthermore, an automatic control system for the array LADAR system is proposed and designed by applying the virtual instrumentation technique. The control system aims to achieve four functions: synchronization of laser emission and rotating platform, multi-channel synchronous data acquisition, real-time Ethernet upper monitoring, and real-time signal processing and 3D visualization. The structure and principle of the complete system are described in the paper. The experimental results demonstrate that the LADAR system is capable of achieving real-time 3D imaging on an omnidirectional rotating platform under the control of the virtual instrumentation system. The automatic imaging LADAR system utilized only 4 LmAPDs to achieve 256-pixel-per-frame detection with by employing 64-bit demodulator. Moreover, the lateral resolution is ∼15 cm and range accuracy is ∼4 cm root-mean-square error at a distance of ∼40 m.

  8. The complete mitochondrial genome of the diamondback moth, Plutella xylostella (Lepidoptera: Plutellidae).

    Science.gov (United States)

    Dai, Li-Shang; Zhu, Bao-Jian; Qian, Cen; Zhang, Cong-Fen; Li, Jun; Wang, Lei; Wei, Guo-Qing; Liu, Chao-Liang

    2016-01-01

    The complete mitochondrial genome (mitogenome) of Plutella xylostella (Lepidoptera: Plutellidae) was determined (GenBank accession No. KM023645). The length of this mitogenome is 16,014 bp with 13 protein-coding genes (PCGs), 2 rRNA genes, 22 tRNA genes and an A + T-rich region. It presents the typical gene organization and order for completely sequenced lepidopteran mitogenomes. The nucleotide composition of the genome is highly A + T biased, accounting for 81.48%, with a slightly positive AT skewness (0.005). All PCGs are initiated by typical ATN codons, except for the gene cox1, which uses CGA as its start codon. Some PCGs harbor TA (nad5) or incomplete termination codon T (cox1, cox2, nad2 and nad4), while others use TAA as their termination codons. The A + T-rich region is located between rrnS and trnM with a length of 888 bp.

  9. Depressive syndromes among female caregivers of schizophrenic patients in prof. dr. m. ildrem mental hospital medan

    Science.gov (United States)

    Handi, A.; Husada, M. S.; Gultom, D. P.

    2018-03-01

    Caring for schizophrenic patients can lead to emotional distress. It remains unclear about the level of depressive syndromes among female caregivers of schizophrenic patients. To determine the level of depression among female caregivers of schizophrenic patients. This is a descriptive study with a cross-sectional approach to describe the level of depression of female caregivers in Prof. dr. M. Ildrem Mental Hospital Medan, using HADS instruments. Most age group of caregivers is from age 51-60 years that is 48.15%, caregiver’s work status mostly not works (62.96%), marital status of caregiver mostly is married (59.26%), kinship with most patients are a biological mother (57.41%). Most patient age group is from age below 30 years (50%), work status of most patients is not working (81.48%), marital status of most caregiver is married (83.33%). Mostly of the depressive syndrome is mild depression (42.59%). Mostly of the depressive syndrome is from mild depression.

  10. Autoimmune progesterone dermatitis: Case report with history of urticaria, petechiae and palpable pinpoint purpura triggered by medical abortion.

    Science.gov (United States)

    Mbonile, Lumuli

    2016-03-17

    Autoimmune progesterone dermatitis (APD) is a rare autoimmune response to raised endogenous progesterone levels that occur during the luteal phase of the menstrual cycle. Cutaneous, mucosal lesions and other systemic manifestations develop cyclically during the luteal phase of the menstrual cycle when progesterone levels are elevated. APD symptoms usually start 3 - 10 days before menstruation and resolve 1 - 2 days after menstruation ceases. A 30-year-old woman presented with urticaria, petechiae and palpable pinpoint purpura lesions of the legs, forearms, neck and buttocks 1 week prior to her menses starting and 2 months after a medical abortion. She was diagnosed with allergic contact dermatitis and topical steroids were prescribed. Her skin conditions did not improve and were associated with her menstrual cycle. We performed an intradermal test using progesterone, which was positive. She was treated with oral contraceptive pills and the symptoms were resolved. This is a typical case of APD triggered by increased sensitivity to endogenous progesterone induced a few months after medical abortion.

  11. BABAR IFR Replacement R and D

    CERN Document Server

    Berry, M

    2003-01-01

    The Instrumented Flux Return (IFR) of the BaBar detector will soon need to be replaced by a more robust muon detection system. Scintillator bars with embedded Wavelength Shifting (WLS) fibers and Limited Streamer Tubes are two replacement technology options. The scintillator bars are tested for attenuation length; and causes for the large width of the Photo Multiplier Tube (PMT) signal are analyzed by Monte Carlo simulation. Cooling techniques for Avalanche Photo Diodes (APD) are investigated. The fairly high attenuation length coupled with the narrow PMT signal make the scintillator a viable option for a muon detecting system. Continuing work will focus on increasing timing resolution using an APD to read the signal from the WLS fibers, and investigating the lifetime of the APD. The ability to read a signal from the LST on external copper strips is tested and signals are found to be clearly distinguishable from noise. The voltage is compared to count rate to find that the optimal operating voltage for the LS...

  12. Assessing Auditory Processing Abilities in Typically Developing School-Aged Children.

    Science.gov (United States)

    McDermott, Erin E; Smart, Jennifer L; Boiano, Julie A; Bragg, Lisa E; Colon, Tiffany N; Hanson, Elizabeth M; Emanuel, Diana C; Kelly, Andrea S

    2016-02-01

    Large discrepancies exist in the literature regarding definition, diagnostic criteria, and appropriate assessment for auditory processing disorder (APD). Therefore, a battery of tests with normative data is needed. The purpose of this study is to collect normative data on a variety of tests for APD on children aged 7-12 yr, and to examine effects of outside factors on test performance. Children aged 7-12 yr with normal hearing, speech and language abilities, cognition, and attention were recruited for participation in this normative data collection. One hundred and forty-seven children were recruited using flyers and word of mouth. Of the participants recruited, 137 children qualified for the study. Participants attended schools located in areas that varied in terms of socioeconomic status, and resided in six different states. Audiological testing included a hearing screening (15 dB HL from 250 to 8000 Hz), word recognition testing, tympanometry, ipsilateral and contralateral reflexes, and transient-evoked otoacoustic emissions. The language, nonverbal IQ, phonological processing, and attention skills of each participant were screened using the Clinical Evaluation of Language Fundamentals-4 Screener, Test of Nonverbal Intelligence, Comprehensive Test of Phonological Processing, and Integrated Visual and Auditory-Continuous Performance Test, respectively. The behavioral APD battery included the following tests: Dichotic Digits Test, Frequency Pattern Test, Duration Pattern Test, Random Gap Detection Test, Compressed and Reverberated Words Test, Auditory Figure Ground (signal-to-noise ratio of +8 and +0), and Listening in Spatialized Noise-Sentences Test. Mean scores and standard deviations of each test were calculated, and analysis of variance tests were used to determine effects of factors such as gender, handedness, and birth history on each test. Normative data tables for the test battery were created for the following age groups: 7- and 8-yr-olds (n = 49), 9

  13. Autoimmune progesterone dermatitis in a patient with endometriosis: case report and review of the literature

    OpenAIRE

    Baptist, Alan P; Baldwin, James L

    2004-01-01

    Abstract Autoimmune progesterone dermatitis (APD) is a condition in which the menstrual cycle is associated with a number of skin findings such as urticaria, eczema, angioedema, and others. In affected women, it occurs 3–10 days prior to the onset of menstrual flow, and resolves 2 days into menses. Women with irregular menses may not have this clear correlation, and therefore may be missed. We present a case of APD in a woman with irregular menses and urticaria/angioedema for over 20 years, w...

  14. FACT — LONGTERM MONITORING OF BRIGHT TeV BLAZARS

    Directory of Open Access Journals (Sweden)

    Katja Meier

    2014-06-01

    Full Text Available The First G-APD Cherenkov Telescope (FACT, located on the Canary Island of La Palma, has been taking data since October 2011. FACT has been optimized for longterm monitoring of bright TeV blazars, to study their variability time scales and flare probability. G-APD photo-sensors allow for observations even under strong moonlight conditions, and the telescope can be operated remotely. The monitoring strategy of FACT is discussed and preliminary results of the flare of Mrk501 in June 2012 are shown.

  15. Vacuum ultra-violet and ultra-violet scintillation light detection by means of silicon photomultipliers at cryogenic temperature

    Energy Technology Data Exchange (ETDEWEB)

    Falcone, A., E-mail: andrea.falcone@pv.infn.it [University of Pavia, via Bassi, 6, 27100 Pavia (Italy); INFN Sezione di Pavia, via Bassi, 6, 27100 Pavia (Italy); Bertoni, R. [INFN Sezione di Milano Bicocca, Piazza della Scienza, 3, 20126 Milano (Italy); Boffelli, F. [University of Pavia, via Bassi, 6, 27100 Pavia (Italy); INFN Sezione di Pavia, via Bassi, 6, 27100 Pavia (Italy); Bonesini, M. [INFN Sezione di Milano Bicocca, Piazza della Scienza, 3, 20126 Milano (Italy); Cervi, T. [University of Pavia, via Bassi, 6, 27100 Pavia (Italy); Menegolli, A. [University of Pavia, via Bassi, 6, 27100 Pavia (Italy); INFN Sezione di Pavia, via Bassi, 6, 27100 Pavia (Italy); Montanari, C.; Prata, M.C.; Rappoldi, A.; Raselli, G.L.; Rossella, M.; Simonetta, M. [INFN Sezione di Pavia, via Bassi, 6, 27100 Pavia (Italy); Spanu, M. [University of Pavia, via Bassi, 6, 27100 Pavia (Italy); Torti, M. [University of Pavia, via Bassi, 6, 27100 Pavia (Italy); INFN Sezione di Pavia, via Bassi, 6, 27100 Pavia (Italy); Zani, A. [INFN Sezione di Pavia, via Bassi, 6, 27100 Pavia (Italy)

    2015-07-01

    We tested the performance of two types of silicon photomultipliers, AdvanSiD ASD-NUV-SiPM3S-P and Hamamatsu 3×3 MM-50 UM VUV2, both at room (300 K) and at liquid nitrogen (77 K) temperature: breakdown voltage, quenching resistance, signal shape, gain and dark counts rate have been studied as function of temperature. The response of the devices to ultra-violet light is also studied. - Highlights: • We tested 2 SiPMs both at room and at cryogenic temperature. • Breakdown voltage, quenching resistance, gain and dark rate were measured. • Efficiency for VUV light detection was measured.

  16. Fabry-Perot interferometry using an image-intensified rotating-mirror streak camera

    International Nuclear Information System (INIS)

    Seitz, W.L.; Stacy, H.L.

    1983-01-01

    A Fabry-Perot velocity interferometer system is described that uses a modified rotating mirror streak camera to recrod the dynamic fringe positions. A Los Alamos Model 72B rotating-mirror streak camera, equipped with a beryllium mirror, was modified to include a high aperture (f/2.5) relay lens and a 40-mm image-intensifier tube such that the image normally formed at the film plane of the streak camera is projected onto the intensifier tube. Fringe records for thin (0.13 mm) flyers driven by a small bridgewire detonator obtained with a Model C1155-01 Hamamatsu and Model 790 Imacon electronic streak cameras are compared with those obtained with the image-intensified rotating-mirror streak camera (I 2 RMC). Resolution comparisons indicate that the I 2 RMC gives better time resolution than either the Hamamatsu or the Imacon for total writing times of a few microseconds or longer

  17. SU-E-I-57: Estimating the Occupational Eye Lens Dose in Interventional Radiology Using Active Personal Dosimeters Worn On the Chest

    Energy Technology Data Exchange (ETDEWEB)

    Omar, A; Marteinsdottir, M; Kadesjo, N; Fransson, A [Dept. of Medical Physics, Karolinska University Hospital, Stockholm (Sweden)

    2015-06-15

    Purpose: To provide a general formalism for determination of occupational eye lens dose based on the response of an active personal dosimeter (APD) worn at chest level above the radiation protection apron. Methods: The formalism consists of three factors: (1) APD conversion factor converting the reading at chest level (APDchest) to the corresponding personal dose equivalent at eye level, (2) Dose conversion factor transferring the measured dose quantity, Hp(10), into a dose quantity relevant for the eye lens dose, (3) Correction factor accounting for differences in exposure of the eye(s) compared to the exposure at chest level (e.g., due to protective lead glasses).The different factors were investigated and evaluated based on phantom and clinical measurements performed in an x-ray angiography suite for interventional cardiology. Results: The eye lens dose can be conservatively estimated by assigning an appropriate numerical value to each factor entering the formalism that in most circumstances overestimates the dose. Doing so, the eye lens dose to the primary operator and assisting staff was estimated in this work as D-eye,primary = 2.0 APDchest and D-eye,assisting = 1.0 APDchest, respectively.The annual eye lens dose to three nurses and one cardiologist was estimated to be 2, 2, 2, and 13 mSv (Hp(0.07)), respectively, using a TLD dosimeter worn at eye level. In comparison, using the formalism and APDchest measurements, the respective doses were 2, 2, 2, and 16 mSv (Hp(3)). Conclusion: The formalism outlined in this work can be used to estimate the occupational eye lens dose from the response of an APD worn on the chest. The formalism is general and could be applied also to other types of dosimeters. However, the numerical value of the different factors may differ from those obtained with the APD’s used in this work due to differences in dosimeter properties.

  18. SU-E-I-57: Estimating the Occupational Eye Lens Dose in Interventional Radiology Using Active Personal Dosimeters Worn On the Chest

    International Nuclear Information System (INIS)

    Omar, A; Marteinsdottir, M; Kadesjo, N; Fransson, A

    2015-01-01

    Purpose: To provide a general formalism for determination of occupational eye lens dose based on the response of an active personal dosimeter (APD) worn at chest level above the radiation protection apron. Methods: The formalism consists of three factors: (1) APD conversion factor converting the reading at chest level (APDchest) to the corresponding personal dose equivalent at eye level, (2) Dose conversion factor transferring the measured dose quantity, Hp(10), into a dose quantity relevant for the eye lens dose, (3) Correction factor accounting for differences in exposure of the eye(s) compared to the exposure at chest level (e.g., due to protective lead glasses).The different factors were investigated and evaluated based on phantom and clinical measurements performed in an x-ray angiography suite for interventional cardiology. Results: The eye lens dose can be conservatively estimated by assigning an appropriate numerical value to each factor entering the formalism that in most circumstances overestimates the dose. Doing so, the eye lens dose to the primary operator and assisting staff was estimated in this work as D-eye,primary = 2.0 APDchest and D-eye,assisting = 1.0 APDchest, respectively.The annual eye lens dose to three nurses and one cardiologist was estimated to be 2, 2, 2, and 13 mSv (Hp(0.07)), respectively, using a TLD dosimeter worn at eye level. In comparison, using the formalism and APDchest measurements, the respective doses were 2, 2, 2, and 16 mSv (Hp(3)). Conclusion: The formalism outlined in this work can be used to estimate the occupational eye lens dose from the response of an APD worn on the chest. The formalism is general and could be applied also to other types of dosimeters. However, the numerical value of the different factors may differ from those obtained with the APD’s used in this work due to differences in dosimeter properties

  19. NEXT-100 Technical Design Report (TDR). Executive summary

    International Nuclear Information System (INIS)

    Álvarez, V; Cárcel, S; Cervera, A; Díaz, J; Ferrario, P; Borges, F I G M; Conde, C A N; Dias, T H V T; Fernandes, L M P; Carmona, J M; Castel, J; Cebrián, S; Dafni, T; Catalá, J M; Esteve, R; Chan, D; Egorov, M; Evtoukhovitch, P; Ferreira, A L; Ferrer-Ribas, E

    2012-01-01

    In this Technical Design Report (TDR) we describe the NEXT-100 detector that will search for neutrinoless double beta decay (ββ0ν) in 136 XE at the Laboratorio Subterráneo de Canfranc (LSC), in Spain. The document formalizes the design presented in our Conceptual Design Report (CDR): an electroluminescence time projection chamber, with separate readout planes for calorimetry and tracking, located, respectively, behind cathode and anode. The detector is designed to hold a maximum of about 150 kg of xenon at 15 bar, or 100 kg at 10 bar. This option builds in the capability to increase the total isotope mass by 50% while keeping the operating pressure at a manageable level. The readout plane performing the energy measurement is composed of Hamamatsu R11410-10 photomultipliers, specially designed for operation in low-background, xenon-based detectors. Each individual PMT will be isolated from the gas by an individual, pressure resistant enclosure and will be coupled to the sensitive volume through a sapphire window. The tracking plane consists in an array of Hamamatsu S10362-11-050P MPPCs used as tracking pixels. They will be arranged in square boards holding 64 sensors (8 × 8) with a 1-cm pitch. The inner walls of the TPC, the sapphire windows and the boards holding the MPPCs will be coated with tetraphenyl butadiene (TPB), a wavelength shifter, to improve the light collection.

  20. NEXT-100 Technical Design Report (TDR). Executive summary

    Science.gov (United States)

    Álvarez, V.; Borges, F. I. G. M.; Cárcel, S.; Carmona, J. M.; Castel, J.; Catalá, J. M.; Cebrián, S.; Cervera, A.; Chan, D.; Conde, C. A. N.; Dafni, T.; Dias, T. H. V. T.; Díaz, J.; Egorov, M.; Esteve, R.; Evtoukhovitch, P.; Fernandes, L. M. P.; Ferrario, P.; Ferreira, A. L.; Ferrer-Ribas, E.; Freitas, E. D. C.; Gehman, V. M.; Gil, A.; Giomataris, I.; Goldschmidt, A.; Gómez, H.; Gómez-Cadenas, J. J.; González, K.; González-Díaz, D.; Gutiérrez, R. M.; Hauptman, J.; Hernando Morata, J. A.; Herrera, D. C.; Herrero, V.; Iguaz, F. J.; Irastorza, I. G.; Kalinnikov, V.; Kiang, D.; Labarga, L.; Liubarsky, I.; Lopes, J. A. M.; Lorca, D.; Losada, M.; Luzón, G.; Marí, A.; Martín-Albo, J.; Martínez, A.; Miller, T.; Moiseenko, A.; Monrabal, F.; Monteiro, C. M. B.; Monzó, J. M.; Mora, F. J.; Moutinho, L. M.; Muñoz Vidal, J.; Natal da Luz, H.; Navarro, G.; Nebot, M.; Nygren, D.; Oliveira, C. A. B.; Palma, R.; Pérez, J.; Pérez Aparicio, J. L.; Renner, J.; Ripoll, L.; Rodríguez, A.; Rodríguez, J.; Santos, F. P.; dos Santos, J. M. F.; Segui, L.; Serra, L.; Shuman, D.; Sofka, C.; Sorel, M.; Toledo, J. F.; Tomás, A.; Torrent, J.; Tsamalaidze, Z.; Vázquez, D.; Velicheva, E.; Veloso, J. F. C. A.; Villar, J. A.; Webb, R. C.; Weber, T.; White, J.; Yahlali, N.

    2012-06-01

    In this Technical Design Report (TDR) we describe the NEXT-100 detector that will search for neutrinoless double beta decay (ββ0ν) in 136XE at the Laboratorio Subterráneo de Canfranc (LSC), in Spain. The document formalizes the design presented in our Conceptual Design Report (CDR): an electroluminescence time projection chamber, with separate readout planes for calorimetry and tracking, located, respectively, behind cathode and anode. The detector is designed to hold a maximum of about 150 kg of xenon at 15 bar, or 100 kg at 10 bar. This option builds in the capability to increase the total isotope mass by 50% while keeping the operating pressure at a manageable level. The readout plane performing the energy measurement is composed of Hamamatsu R11410-10 photomultipliers, specially designed for operation in low-background, xenon-based detectors. Each individual PMT will be isolated from the gas by an individual, pressure resistant enclosure and will be coupled to the sensitive volume through a sapphire window. The tracking plane consists in an array of Hamamatsu S10362-11-050P MPPCs used as tracking pixels. They will be arranged in square boards holding 64 sensors (8 × 8) with a 1-cm pitch. The inner walls of the TPC, the sapphire windows and the boards holding the MPPCs will be coated with tetraphenyl butadiene (TPB), a wavelength shifter, to improve the light collection.

  1. HgCdTe APDS for space applications

    Science.gov (United States)

    Rothman, Johan; de Broniol, Eric; Foubert, Kevin; Mollard, Laurent; Péré-Laperne, Nicolas; Salvetti, Frederic; Kerlain, Alexandre; Reibel, Yann

    2017-11-01

    HgCdTe avalanche photodiode focal plane arrays (FPAs) and single element detectors have been developed for a large scope of photon starved applications. The present communication present the characteristics of our most recent detector developments that opens the horizon for low infrared (IR) photon number detection with high information conservation for imaging, atmospheric lidar and free space telecommunications. In particular, we report on the performance of TEC cooled large area detectors with sensitive diameters ranging from 30- 200 μm, characterised by detector gains of 2- 20 V/μW and noise equivalent input power of 0.1-1 nW for bandwidths ranging from 20 to 400 MHz.

  2. Comparable Bioavailability of two esophago-gastric protective formulations containing pamidronate: a cross-over trial in healthy young adults Biodisponibilidad comparable de dos formulaciones gastroprotectoras que contienen pamidronato: Un estudio cruzado en voluntarios sanos

    Directory of Open Access Journals (Sweden)

    Emilio J.A. Roldan

    2002-08-01

    Full Text Available The net absorbable amount of pamidronate (APD, according to AUC values assessed in blood, in the customary dose interval of 24 hours, was found to be similar in 8 healthy young volunteers, who received single doses of 3 capsules of 100 mg APD (AUC0-24= 510.3 ± 91.5 µg/Lxh-1 and 2 tablets of 150 mg (AUC0-24 = 580.5 ± 117.6 µg/Lxh-1; p= 0.58 in the fasting state. Both formulations present acid-resistant coatings, designed to protect the mucosa of the upper digestive system from contact with insoluble particles of the bisphosphonates. Tmax values were different, and Cmax values presented a wide inter-individual variation, so that both formulations were not strictly bioequivalent. However, these latter factors were of minor clinical importance given the kinetic features of the bisphosphonates. In conclusion, both formulations afforded comparable bioavailability; that is to say that they can provide a sufficient amount of APD within the studied dose interval, so as to cause similar clinical effects.Las cantidades netas absorbidas de pamidronato (APD, de acuerdo con el área bajo la curva de concentraciones sanguíneas, calculadas en el intervalo de dosis habitual de 24 horas, fueron en promedio similares en 8 voluntarios sanos; quienes en ayuno recibieron dosis únicas de 3 cápsulas de 100 mg APD (AUC0-24= 510.3 ± 91.5 µg/Lxh-1 y 2 comprimidos de 150 mg (AUC0-24 = 580.5 ± 117.6 µg/Lxh-1; p= 0.58. Ambas formulaciones presentan cubiertas resistentes al medio ácido, diseñadas para proteger las mucosas del sistema digestivo superior del contacto e irritación proveniente de las partículas insolubles del bisfosfonato. Los valores de Tmax fueron diferentes y los de Cmax presentaron una amplia variación interindi-vidual, por lo que ambas formulaciones no fueron estrictamente bioequivalentes. De todos modos, estas últimas variables son de una importancia clínica menor teniendo en cuenta las características cinéticas especiales de los

  3. Photochemical smog incident on June 30, 1973

    Energy Technology Data Exchange (ETDEWEB)

    Hata, S

    1973-01-01

    The first photochemical smog incident in Shizuoka prefecture (June 30, 1973) started in Hamamatsu and extended 100 km northeast as far as Fujinomiya city. This not only involved an extraordinarily large area, but the type of smog was different from that in Tokyo and Osaka. The victims were all pupils exercising at the time in the playgrounds. In Hamamatsu, 1050 children were involved and complained of eye irritation and pain, throat pain, coughs, and headaches between 2 and 3 pm, but there were no serious effects. The damages to agricultural produce were extensive and 70% of the total rice fields (1656 hectares), and 40 hectares of green scallions were affected. In Shizuoka, 716 children were affected about 5:30 pm, but in Fujinomiya, which is located further northeast, 16 children were affected about 4 pm. The movement of the damages, the locations, the extent of damages, and the direction of the wind, were puzzling in the light of the normal pattern of photochemical smogs, and the pollution sources could not be the coastal industrial area or automobile exhaust gases. Meteorological factors were similar to the usual photochemical smog conditions, but the locations of the cities involved and the wind direction from the sea suggested that the pollution source was the Pacific Ocean. Since the wind above 1000 m was northeast, circulation of industrial pollutants by the sea breeze is a possible explanation. The maximum concentration of oxidants was about 0.2 ppm in all areas except for Hamamatsu, where it was a little over 0.2 ppm.

  4. PERAN-SERTA PEMILIK INDUSTRI TERHADAP PERILAKU PEMAKAIAN ALAT PELINDUNG DIRI PADA PEKERJA PAHAT BATU DI TAMANAGUNG MUNTILAN

    Directory of Open Access Journals (Sweden)

    Nurul Asna

    2016-05-01

    Full Text Available Lingkungan kerja pekerja pahat batu di Desa Tamanagung, Muntilan, memiliki potensi bahaya yang dapat menimbulkan gangguan kesehatan. Potensi bahaya tersebut dapat dicegah melalui pemakaian APD yang benar dan rutin. Namun demikian, dalam praktiknya, sebagian besar pe-kerja di sana tidak terbiasa menggunakannya. Oleh karena itu, peran pemilik sebagai penang-gung-jawab untuk mengingatkan dan menegur pekerja perlu diwujudkan. Tujuan penelitian ini untuk membuktikan bahwa peran-serta pemilik industri dapat meningkatkan pengetahuan, si-kap, dan praktik pekerja dalam pemakaian APD. Jenis penelitian yang dilakukan adalah ekspe-rimen semu dengan desain non-randomized pre-test post-test with control group. Subyek pene-litian adalah pekerja dari sembilan industri pahat batu, yakni 31 pekerja dari 4 industri sebagai kelompok ekperimen dan 32 pekerja dari 5 industri sebagai kelompok kontrol. Hasil penelitian menunjukkan terjadi peningkatan rata-rata nilai pengetahuan, sikap, dan praktik pada kelompok eksperimen, secara berturut-turut sebesar 9,48; 3,42; dan 3,55; dan pada kelompok kontrol, secara berturut-turut sebesar 2,69; 1,44; dan 2,22. Analisis secara non-parametrik dengan uji Mann Whitney pada derajat signifikansi 95 % menyatakan bahwa perbedaan kenaikan tingkat pengetahuan dan sikap atas pemakaian APD oleh pekerja adalah bermakna (nilai-p < 0,05, sementara untuk perbedaan kenaikan tingkat praktik, tidak bermakna (nilai-p = 0,083. Dari ha-sil tersebut dapat disimpulkan bahwa peran-serta pemilik industri berpengaruh terhadap penge-tahuan dan sikap pekerja pahat batu dalam memakai APD.

  5. Novel Photon-Counting Detectors for Free-Space Communication

    Science.gov (United States)

    Krainak, Michael A.; Yang, Guan; Sun, Xiaoli; Lu, Wei; Merritt, Scott; Beck, Jeff

    2016-01-01

    We present performance data for novel photon counting detectors for free space optical communication. NASA GSFC is testing the performance of three novel photon counting detectors 1) a 2x8 mercury cadmium telluride avalanche array made by DRS Inc. 2) a commercial 2880 silicon avalanche photodiode array and 3) a prototype resonant cavity silicon avalanche photodiode array. We will present and compare dark count, photon detection efficiency, wavelength response and communication performance data for these detectors. We discuss system wavelength trades and architectures for optimizing overall communication link sensitivity, data rate and cost performance. The HgCdTe APD array has photon detection efficiencies of greater than 50 were routinely demonstrated across 5 arrays, with one array reaching a maximum PDE of 70. High resolution pixel-surface spot scans were performed and the junction diameters of the diodes were measured. The junction diameter was decreased from 31 m to 25 m resulting in a 2x increase in e-APD gain from 470 on the 2010 array to 1100 on the array delivered to NASA GSFC. Mean single photon SNRs of over 12 were demonstrated at excess noise factors of 1.2-1.3.The commercial silicon APD array has a fast output with rise times of 300ps and pulse widths of 600ps. Received and filtered signals from the entire array are multiplexed onto this single fast output. The prototype resonant cavity silicon APD array is being developed for use at 1 micron wavelength.

  6. A European Perspective on Auditory Processing Disorder-Current Knowledge and Future Research Focus

    Directory of Open Access Journals (Sweden)

    Vasiliki (Vivian Iliadou

    2017-11-01

    Full Text Available Current notions of “hearing impairment,” as reflected in clinical audiological practice, do not acknowledge the needs of individuals who have normal hearing pure tone sensitivity but who experience auditory processing difficulties in everyday life that are indexed by reduced performance in other more sophisticated audiometric tests such as speech audiometry in noise or complex non-speech sound perception. This disorder, defined as “Auditory Processing Disorder” (APD or “Central Auditory Processing Disorder” is classified in the current tenth version of the International Classification of diseases as H93.25 and in the forthcoming beta eleventh version. APDs may have detrimental effects on the affected individual, with low esteem, anxiety, and depression, and symptoms may remain into adulthood. These disorders may interfere with learning per se and with communication, social, emotional, and academic-work aspects of life. The objective of the present paper is to define a baseline European APD consensus formulated by experienced clinicians and researchers in this specific field of human auditory science. A secondary aim is to identify issues that future research needs to address in order to further clarify the nature of APD and thus assist in optimum diagnosis and evidence-based management. This European consensus presents the main symptoms, conditions, and specific medical history elements that should lead to auditory processing evaluation. Consensus on definition of the disorder, optimum diagnostic pathway, and appropriate management are highlighted alongside a perspective on future research focus.

  7. Intercomparison of active personal dosemeters in interventional radiology

    International Nuclear Information System (INIS)

    Clairand, I.; Struelens, L.; Bordy, J. M.; Daures, J.; Debroas, J.; Denozieres, M.; Donadille, L.; Gouriou, J.; Itie, C.; Vaz, P.; D'Errico, F.

    2008-01-01

    The use of active personal dosemeters (APD) in interventional radiology was evaluated by Working Group 9 (Radiation protection dosimetry of medical staff) of the CONRAD project, which is a Coordination Action supported by the European Commission within its sixth Framework Programme. Interventional radiology procedures can be very complex and they can lead to relatively high doses to personnel who stand close to the primary radiation field and are mostly exposed to radiation scattered by the patient. For the adequate dosimetry of the scattered photons, APDs must be able to respond to low-energy [10-100 keV] and pulsed radiation with relatively high instantaneous dose rates. An intercomparison of five APD models deemed suitable for application in interventional radiology was organised in March 2007. The intercomparison used pulsed and continuous radiation beams, at CEA-LIST (Saclay (France)) and IRSN (Fontenay-aux-Roses (France)), respectively. A specific configuration, close to the clinical practice, was considered. The reference dose, in terms of Hp(10), was derived from air kerma measurements and from the measured and calculated energy distributions of the scattered radiation field. Additional Monte Carlo calculations were performed to investigate the energy spectra for different experimental conditions of the intercomparison. The results of this intercomparison are presented in this work and indicate which APDs are able to provide a correct response when used in the specific low-energy spectra and dose rates of pulsed X-rays encountered in interventional radiology. (authors)

  8. Application of avalanche photodiodes for the measurement of actinides by alpha liquid scintillation counting

    International Nuclear Information System (INIS)

    Reboli, A.

    2005-10-01

    Alpha emitters analysis using liquid scintillation spectroscopy is often used when sensitivity and fast samples preparation are the important points. A more extensive use of this technique is until now limited by its poor resolution compared to alpha particle spectroscopy with semiconductor detectors. To improve the resolution and thus promote this method for the measurement of actinides in environment, we have tested silicon avalanche photodiodes (APD) as new detectors for scintillation photons. The set-up consists of a large area avalanche photodiode (16 mm diameter) coupled to a thin vial containing alpha-emitters within a liquid scintillation cocktail. After optimization of several parameters like bias voltage, temperature, counting geometry and composition of the scintillating cocktail, energy resolutions have been found to be better than those obtained with standard photomultiplier tubes (PMT): 5% (200 keV FWHM) for 232 Th and 4.2% (240 keV FWHM) for 236 Pu. Our results show that the improvement is due to less fluctuations associated with light collection since the spatial response of APDs is more uniform than that of PMTs. The expected gain on quantum efficiency (80% for APDs instead of 25% for PMTs) is nullified by a corresponding increase on electronic noise and excess noise factor. Significant better results are foreseen by using green scintillators (450 - 550 nm wavelengths region) with larger Stokes-shift and blue-enhanced APDs which reach their maximum quantum efficiency in this region. (author)

  9. Qualidade do inhame 'Da Costa' em função das épocas de colheita e da adubação orgânica Da Costa yam quality in relation to harvest time and organic fertilization

    Directory of Open Access Journals (Sweden)

    Ademar P. de Oliveira

    2002-03-01

    Full Text Available Foi desenvolvido um trabalho na EMEPA em João Pessoa, entre setembro/98 e junho/99, com o objetivo de quantificar o teor de matéria seca, de amido e de cinzas em rizomas do inhame, cultivar Da Costa, em função das épocas de colheita e da adubação orgânica, em solo Podzólico Vermelho-Amarelo, textura arenosa. Estudaram-se níveis de esterco bovino (5; 10; 15 e 20 t/ha e de esterco de galinha (2,8; 5,6; 8,4 e 11,2 t/ha, duas épocas de colheita (sete e nove meses após o plantio e uma testemunha, sem resíduo orgânico. Os tratamentos foram arranjados como fatorial 2x4x2+1, no delineamento de blocos casualizados, com quatro repetições. O teor de matéria seca nos rizomas aumentou com a maturidade do cará-da-costa, passando de 33% em rizomas colhidos aos sete meses, para 36% em rizoma colhidos aos nove meses. Os teores de matéria seca nos rizomas colhidos aos sete meses decresceram de 35,80% e 34,71%, respectivamente, na ausência de estercos para 30,03% e 29,25%, respectivamente, com as doses de 20 t/ha de esterco bovino e de 11,2 t/ha de esterco de galinha. Na colheita realizada aos sete meses, o teor de amido foi de 26%, elevando-se para 29% na colheita aos noves meses. O teor de amido, na colheita realizada aos nove meses, aumentou com as doses de esterco de galinha, atingindo o máximo de 31,6% com a dose de 4,8 t/ha. O teor de cinzas nos rizomas não foi influenciado pelas épocas de colheita, mas naqueles colhidos aos nove meses, o teor aumentou com as doses de esterco bovino e de galinha, atingindo o máximo de 0,78 e 0,67%, respectivamente, nas doses de 12,8 e 6,7 t/ha.An experiment was carried out in EMEPA, João Pessoa, Brazil between September 98 and June 99 to quantify the dry matter, starch and ash content of yam rhizomes, cv. Da Costa, in relation to harvest time and organic fertilization. The area consisted of a red-yellow podzolic sandy soil. Four levels of cattle manure (5; 10; 15 and 20 t/ha, four levels of chicken

  10. Calibrazione dei fotomoltiplicatori di AMS, esperimento spaziale per la ricerca dell'antimateria

    CERN Document Server

    Alvisi, D

    1998-01-01

    In this thesis is presented the gain measure, qualification and choiceof the 336 Hamamatsu R5900 photomultipliers that are used in theAMS-01 Time of Flight (TOF) system.The special procedures and tecniques to operate the photomultipliers in space are also illustrated. (Italian text)

  11. Small-conductance calcium-activated potassium (SK) channels contribute to action potential repolarization in human atria

    DEFF Research Database (Denmark)

    Skibsbye, Lasse; Poulet, Claire; Diness, Jonas Goldin

    2014-01-01

    (+) currents by ∼15% and prolonged action potential duration (APD), but no effect was observed in myocytes from AF patients. In trabeculae muscle strips from right atrial appendages of SR patients, both compounds increased APD and effective refractory period, and depolarized the resting membrane potential......, while only NS8593 induced these effects in tissue from AF patients. SK channel inhibition did not alter any electrophysiological parameter in human interventricular septum tissue. CONCLUSIONS: SK channels are present in human atria where they participate in repolarization. SK2 and SK3 were down...

  12. Azimuthal spectrum after parametric down-convertion with radial degrees of freedom

    CSIR Research Space (South Africa)

    Zhang, Y

    2014-08-01

    Full Text Available of the OAM spectrum, i.e. the spiral bandwidth.6–10 Hence, a large spiral bandwidth indicates that an OAM entangled quantum state contains more OAM degrees of freedom that can be used to encode quantum information. The Laguerre-Gaussian (LG) modes are OAM... counter (CC). 50/50 beam splitter Laser BBO A B SLM SLM SMF SMF CC APD APD Signal Idler Figure 1. Diagram of the experimental setup used to prepare and measure the OAM entangled photon pairs. 3.2 Modelling the experiment Due to the experimental parameters...

  13. Ablation of polymers by ultraviolet pulsed laser

    International Nuclear Information System (INIS)

    Brezini, A.; Benharrats, N.

    1993-08-01

    The surface modifications of different polymers treated by far UV-Excimer laser (λ = 193mn, 248, 308nm) are analysed by X-Ray Photoelectrons Spectroscopy. The main feature observed depends strongly on the absorption coefficients. For the high absorbing polymers such (PVC, PS, PI,...) the mechanism of the UV-Excimer Laser interaction appears to be governed by an ablative photodecomposition process (APD) with an APD threshold. In the other limit, i.e. low absorbing polymer the interaction leads to a photothermal process. (author). 51 refs, 24 figs, 7 tabs

  14. Single-photon counting in the 1550-nm wavelength region for quantum cryptography

    International Nuclear Information System (INIS)

    Park, Chul-Woo; Park, Jun-Bum; Park, Young-Soo; Lee, Seung-Hun; Shin, Hyun-Jun; Bae, Byung-Seong; Moon, Sung; Han, Sang-Kook

    2006-01-01

    In this paper, we report the measured performance of an InGaAs avalanche photodiode (APD) Module fabricated for single-photon counting. We measured the dark current noise, the after-pulse noise, and the quantum efficiency of the single- photon detector for different temperatures. We then examined our single-photon source and detection system by measuring the coincident probability. From our measurement, we observed that the after-pulse effect of the APD at temperatures below 105 .deg. C caused cascade noise build-up on the succeeding electrical signals.

  15. The signal shape from the LHCb vertex locator prototype detectors

    International Nuclear Information System (INIS)

    Charles, M.

    2003-01-01

    Measurements of the SCT128A ASIC pulse shape, when reading out non-irradiated and irradiated prototype detectors for the LHCb VELO, are presented. The detectors studied were two n-on-n prototype detectors fabricated by Hamamatsu, and a p-on-n prototype detector fabricated by MICRON

  16. Noise Filter Studies for CMS Forward Hadron Calorimeter (HF) Between Old and New PMT's Using Data in 2012

    CERN Document Server

    Dumanoglu, Isa; Gurpinar, Emine; Kunori, Shuichi; Lezki, Samet; Tali, Bayram

    2016-01-01

    During the data taking before 2012 some abnormal events which have higher signals than expected were observed. Most of these were due to muons. When a muon hits the PMT glass window it creates a huge signal. To eliminate this kind of events 24 old HF PMTs (Hamamatsu R7525) in HF Minus at iphi 43 (corresponds to one sector) were replaced with new multi anode PMTs (Hamamatsu multi anode R7600) which have thin glass windows. These new PMTs were installed and tested in H2 test beam area in 2009 [1]. To check whether these new PMTs perform better than the old ones data taken in 2012 were analyzed using various predefined noise filters. Noisy rechits percentage was found to be around 6-7 \\% for the new PMTs while it varies between 29-66 \\% for the old PMTs for various trigger selections and for HFLongShortFilter after an energy cut of 500GeV [2].

  17. Gigahertz-gated InGaAs/InP single-photon detector with detection efficiency exceeding 55% at 1550 nm

    International Nuclear Information System (INIS)

    Comandar, L. C.; Fröhlich, B.; Dynes, J. F.; Sharpe, A. W.; Lucamarini, M.; Yuan, Z. L.; Shields, A. J.; Penty, R. V.

    2015-01-01

    We report on a gated single-photon detector based on InGaAs/InP avalanche photodiodes (APDs) with a single-photon detection efficiency exceeding 55% at 1550 nm. Our detector is gated at 1 GHz and employs the self-differencing technique for gate transient suppression. It can operate nearly dead time free, except for the one clock cycle dead time intrinsic to self-differencing, and we demonstrate a count rate of 500 Mcps. We present a careful analysis of the optimal driving conditions of the APD measured with a dead time free detector characterization setup. It is found that a shortened gate width of 360 ps together with an increased driving signal amplitude and operation at higher temperatures leads to improved performance of the detector. We achieve an afterpulse probability of 7% at 50% detection efficiency with dead time free measurement and a record efficiency for InGaAs/InP APDs of 55% at an afterpulse probability of only 10.2% with a moderate dead time of 10 ns

  18. Front-end electronics for the ALICE calorimeters

    CERN Document Server

    Wang, Ya-Ping; Muller, Hans; Cai, Xu; Zhou, Daicui; Yin, Zhong-Bao; Awes, Terry C.; Wang, Dong

    2010-01-01

    The ALICE calorimeters PHOS and EMCal are based on Avalanche Photo-Diode (APD) photosensors with Charge Sensitive Preamplifiers (CSP) for readout of the scintillating elements. The amplified signals are read out via 32-channel shaper/digitizer front-end electronics (FEE) with 14-bit effective dynamic range. The electronics is based on second order shapers with dual gain for each channel, getting digitized by ALTRO chips. Each APD channel is equipped with an individual 10-bit APD gain adjustment and 2×2 channel clusters generate a 100 ns shaped analog sums output (Fast OR) for the associated Trigger Region Units (TRU). The Fast OR signals are generated by first order shapers with a dynamic range of 12-bit given by the ADC in the TRU cards. Board controller firmware in the FPGA provides local monitoring and configuration of all parameters via the ALICE DCS system. The signal to noise ratio for MIP at 215 MeV is not, vert, similar7 per channel with a noise level of 30 MeV at room temperature for a dynamic range...

  19. CO, Pb++ and SO2 effects on L-type calcium channel and action potential in human atrial myocytes. In silico study

    Directory of Open Access Journals (Sweden)

    Diana C. Pachajoa

    2017-09-01

    Full Text Available Exposure to air pollutants like carbon monoxide (CO, lead (Pb++ and sulfur dioxide (SO2 promotes the occurrence of cardiovascular diseases. Experimental studies have shown that CO, Pb++ and SO2 block L-type calcium channels, reducing the calcium current (ICaL and the action potential duration (APD, which favors the initiation of atrial arrhythmias. The goal is to study the effects of CO, Pb++ and SO2 at different concentrations on ICaL and action potential using computational simulation. For this purpose, models of the effects of the air pollutants on the atrial L-type calcium channel were developed and were incorporated into a mathematical model of a human atrial cell. The results suggest that CO, Pb++ and SO2 block the ICaL current in a fraction that increases along with the concentration, generating an APD shortening. These results are consistent with experimental studies. The combined effect of the three air pollutants produced an APD shortening, which is considered to be a pro-arrhythmic effect.

  20. Simulation and Noise Analysis of Multimedia Transmission in Optical CDMA Computer Networks

    Directory of Open Access Journals (Sweden)

    Nasaruddin Nasaruddin

    2013-09-01

    Full Text Available This paper simulates and analyzes noise of multimedia transmission in a flexible optical code division multiple access (OCDMA computer network with different quality of service (QoS requirements. To achieve multimedia transmission in OCDMA, we have proposed strict variable-weight optical orthogonal codes (VW-OOCs, which can guarantee the smallest correlation value of one by the optimal design. In developing multimedia transmission for computer network, a simulation tool is essential in analyzing the effectiveness of various transmissions of services. In this paper, implementation models are proposed to analyze the multimedia transmission in the representative of OCDMA computer networks by using MATLAB simulink tools. Simulation results of the models are discussed including spectrums outputs of transmitted signals, superimposed signals, received signals, and eye diagrams with and without noise. Using the proposed models, multimedia OCDMA computer network using the strict VW-OOC is practically evaluated. Furthermore, system performance is also evaluated by considering avalanche photodiode (APD noise and thermal noise. The results show that the system performance depends on code weight, received laser power, APD noise, and thermal noise which should be considered as important parameters to design and implement multimedia transmission in OCDMA computer networks.

  1. Simulation and Noise Analysis of Multimedia Transmission in Optical CDMA Computer Networks

    Directory of Open Access Journals (Sweden)

    Nasaruddin

    2009-11-01

    Full Text Available This paper simulates and analyzes noise of multimedia transmission in a flexible optical code division multiple access (OCDMA computer network with different quality of service (QoS requirements. To achieve multimedia transmission in OCDMA, we have proposed strict variable-weight optical orthogonal codes (VW-OOCs, which can guarantee the smallest correlation value of one by the optimal design. In developing multimedia transmission for computer network, a simulation tool is essential in analyzing the effectiveness of various transmissions of services. In this paper, implementation models are proposed to analyze the multimedia transmission in the representative of OCDMA computer networks by using MATLAB simulink tools. Simulation results of the models are discussed including spectrums outputs of transmitted signals, superimposed signals, received signals, and eye diagrams with and without noise. Using the proposed models, multimedia OCDMA computer network using the strict VW-OOC is practically evaluated. Furthermore, system performance is also evaluated by considering avalanche photodiode (APD noise and thermal noise. The results show that the system performance depends on code weight, received laser power, APD noise, and thermal noise which should be considered as important parameters to design and implement multimedia transmission in OCDMA computer networks.

  2. Wideband LTE Power Amplifier with Integrated Novel Analog Pre-Distorter Linearizer for Mobile Wireless Communications

    Science.gov (United States)

    Uthirajoo, Eswaran; Ramiah, Harikrishnan; Kanesan, Jeevan; Reza, Ahmed Wasif

    2014-01-01

    For the first time, a new circuit to extend the linear operation bandwidth of a LTE (Long Term Evolution) power amplifier, while delivering a high efficiency is implemented in less than 1 mm2 chip area. The 950 µm × 900 µm monolithic microwave integrated circuit (MMIC) power amplifier (PA) is fabricated in a 2 µm InGaP/GaAs process. An on-chip analog pre-distorter (APD) is designed to improve the linearity of the PA, up to 20 MHz channel bandwidth. Intended for 1.95 GHz Band 1 LTE application, the PA satisfies adjacent channel leakage ratio (ACLR) and error vector magnitude (EVM) specifications for a wide LTE channel bandwidth of 20 MHz at a linear output power of 28 dBm with corresponding power added efficiency (PAE) of 52.3%. With a respective input and output return loss of 30 dB and 14 dB, the PA’s power gain is measured to be 32.5 dB while exhibiting an unconditional stability characteristic from DC up to 5 GHz. The proposed APD technique serves to be a good solution to improve linearity of a PA without sacrificing other critical performance metrics. PMID:25033049

  3. Using 3.05 MeV resonance for determination of oxygen impurities

    International Nuclear Information System (INIS)

    Burkova, I.E.; Polyanskij, V.N.; Yatis, A.A.

    1983-01-01

    The method of determining oxygen impurities behind thin films using the isolated resonance in the 16 O(α, α) 16 O reaction at E=3.048 MeV with the width GITA approximately 20 keV, is considered. Cross section in resonance is σsUb(R) = 0.95 b apd it increases cross section of Rutherford scattering by the factor of 25. The conclusion is made on the possibility of using 3.048 MeV resonance when investigating Me-Si film structures

  4. Database-Guided Discovery of Potent Peptides to Combat HIV-1 or Superbugs

    Directory of Open Access Journals (Sweden)

    Guangshun Wang

    2013-05-01

    Full Text Available Antimicrobial peptides (AMPs, small host defense proteins, are indispensable for the protection of multicellular organisms such as plants and animals from infection. The number of AMPs discovered per year increased steadily since the 1980s. Over 2,000 natural AMPs from bacteria, protozoa, fungi, plants, and animals have been registered into the antimicrobial peptide database (APD. The majority of these AMPs (>86% possess 11–50 amino acids with a net charge from 0 to +7 and hydrophobic percentages between 31–70%. This article summarizes peptide discovery on the basis of the APD. The major methods are the linguistic model, database screening, de novo design, and template-based design. Using these methods, we identified various potent peptides against human immunodeficiency virus type 1 (HIV-1 or methicillin-resistant Staphylococcus aureus (MRSA. While the stepwise designed anti-HIV peptide is disulfide-linked and rich in arginines, the ab initio designed anti-MRSA peptide is linear and rich in leucines. Thus, there are different requirements for antiviral and antibacterial peptides, which could kill pathogens via different molecular targets. The biased amino acid composition in the database-designed peptides, or natural peptides such as θ-defensins, requires the use of the improved two-dimensional NMR method for structural determination to avoid the publication of misleading structure and dynamics. In the case of human cathelicidin LL-37, structural determination requires 3D NMR techniques. The high-quality structure of LL-37 provides a solid basis for understanding its interactions with membranes of bacteria and other pathogens. In conclusion, the APD database is a comprehensive platform for storing, classifying, searching, predicting, and designing potent peptides against pathogenic bacteria, viruses, fungi, parasites, and cancer cells.

  5. Proarrhythmic remodelling of the right ventricle in a porcine model of repaired tetralogy of Fallot

    Science.gov (United States)

    Benoist, David; Dubes, Virginie; Roubertie, François; Gilbert, Stephen H; Charron, Sabine; Constantin, Marion; Elbes, Delphine; Vieillot, Delphine; Quesson, Bruno; Cochet, Hubert; Haïssaguerre, Michel; Rooryck, Caroline; Bordachar, Pierre; Thambo, Jean-Benoit; Bernus, Olivier

    2017-01-01

    Objective The growing adult population with surgically corrected tetralogy of Fallot (TOF) is at risk of arrhythmias and sudden cardiac death. We sought to investigate the contribution of right ventricular (RV) structural and electrophysiological remodelling to arrhythmia generation in a preclinical animal model of repaired TOF (rTOF). Methods and results Pigs mimicking rTOF underwent cardiac MRI functional characterisation and presented with pulmonary regurgitation, RV hypertrophy, dilatation and dysfunction compared with Sham-operated animals (Sham). Optical mapping of rTOF RV-perfused wedges revealed a significant prolongation of RV activation time with slower conduction velocities and regions of conduction slowing well beyond the surgical scar. A reduced protein expression and lateralisation of Connexin-43 were identified in rTOF RVs. A remodelling of extracellular matrix-related gene expression and an increase in collagen content that correlated with prolonged RV activation time were also found in these animals. RV action potential duration (APD) was prolonged in the epicardial anterior region at early and late repolarisation level, thus contributing to a greater APD heterogeneity and to altered transmural and anteroposterior APD gradients in rTOF RVs. APD remodelling involved changes in Kv4.3 and MiRP1 expression. Spontaneous arrhythmias were more frequent in rTOF wedges and more complex in the anterior than in the posterior RV. Conclusion Significant remodelling of RV conduction and repolarisation properties was found in pigs with rTOF. This remodelling generates a proarrhythmic substrate likely to facilitate re-entries and to contribute to sudden cardiac death in patients with rTOF. PMID:28051771

  6. Development of HgCdTe large format MBE arrays and noise-free high speed MOVPE EAPD arrays for ground based NIR astronomy

    Science.gov (United States)

    Finger, G.; Baker, I.; Downing, M.; Alvarez, D.; Ives, D.; Mehrgan, L.; Meyer, M.; Stegmeier, J.; Weller, H. J.

    2017-11-01

    Large format near infrared HgCdTe 2Kx2K and 4Kx4K MBE arrays have reached a level of maturity which meets most of the specifications required for near infrared (NIR) astronomy. The only remaining problem is the persistence effect which is device specific and not yet fully under control. For ground based multi-object spectroscopy on 40 meter class telescopes larger pixels would be advantageous. For high speed near infrared fringe tracking and wavefront sensing the only way to overcome the CMOS noise barrier is the amplification of the photoelectron signal inside the infrared pixel by means of the avalanche gain. A readout chip for a 320x256 pixel HgCdTe eAPD array will be presented which has 32 parallel video outputs being arranged in such a way that the full multiplex advantage is also available for small sub-windows. In combination with the high APD gain this allows reducing the readout noise to the subelectron level by applying nondestructive readout schemes with subpixel sampling. Arrays grown by MOVPE achieve subelectron readout noise and operate with superb cosmetic quality at high APD gain. Efforts are made to reduce the dark current of those arrays to make this technology also available for large format focal planes of NIR instruments offering noise free detectors for deep exposures. The dark current of the latest MOVPE eAPD arrays is already at a level adequate for noiseless broad and narrow band imaging in scientific instruments.

  7. Comorbid depression, antisocial personality, and substance dependence: Relationship with delay discounting.

    Science.gov (United States)

    Moody, Lara; Franck, Christopher; Bickel, Warren K

    2016-03-01

    Within the field of addiction, as many as four-fifths of individuals in treatment for substance use disorder have co-existing lifetime psychopathology and as high as two-thirds have current psychopathology. Among substance-dependent individuals, excessive delay discounting is pervasive. Despite evidence of excessive discounting across substance use disorders, few studies have investigated the impact of co-occurring psychopathologies and SUD on delay discounting. We compared delay discounting in currently abstaining substance users with (a) SUD (n=166), (b) SUD and managed major depressive disorder (MDD; n=44), (c) SUD and antisocial personality disorder (APD; n=35), (d) SUD and managed MDD and APD (n=22) and (e) no SUD or co-occurring psychopathology (n=60). All groups with SUD discounted future delayed rewards significantly more than healthy controls (p<0.001 in each case, d=0.686, 0.835, 1.098 and 1.650, respective to groups a-d above). Individuals with both APD and SUD and individuals with MDD, APD, and SUD discounted future rewards significantly more than substance users without comorbid psychopathology (p=0.029, d=0.412 and p<0.001, d=0.964, respectively). Overall, individuals with multiple psychopathologies in addition to substance use have exacerbated deficits in discounting of the future, above and beyond that observed in substance use alone. Increased discounting in combined substance and psychopathology profiles suggest a greater chance of treatment failure and therefore may necessitate individualized treatment using adjunctive interventions to achieve better treatment outcomes. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  8. Esperimento AMS: problemi teorici e sperimentali nella ricerca di antimateria in raggi cosmici

    OpenAIRE

    Casadei, D

    1998-01-01

    In this thesis are reported the design and the tests that have been done on the prototype counters of the Time of Flight (TOF) system of the AMS (Alpha Magnetic Spectrometer) experiment. The behaviour of the Hamamatsu R5900 under vacuum test is also shown. (text is in italian)

  9. Esperimento AMS problemi teorici e sperimentali nella ricerca di antimateria in raggi cosmici

    CERN Document Server

    Casadei, D

    1998-01-01

    In this thesis are reported the design and the tests that have been done on the prototype counters of the Time of Flight (TOF) system of the AMS (Alpha Magnetic Spectrometer) experiment. The behaviour of the Hamamatsu R5900 under vacuum test is also shown. (text is in italian)

  10. The silicon microstrip sensors of the ATLAS semiconductor tracker

    Energy Technology Data Exchange (ETDEWEB)

    ATLAS SCT Collaboration; Spieler, Helmuth G.

    2007-04-13

    This paper describes the AC-coupled, single-sided, p-in-n silicon microstrip sensors used in the Semiconductor Tracker (SCT) of the ATLAS experiment at the CERN Large Hadron Collider (LHC). The sensor requirements, specifications and designs are discussed, together with the qualification and quality assurance procedures adopted for their production. The measured sensor performance is presented, both initially and after irradiation to the fluence anticipated after 10 years of LHC operation. The sensors are now successfully assembled within the detecting modules of the SCT, and the SCT tracker is completed and integrated within the ATLAS Inner Detector. Hamamatsu Photonics Ltd. supplied 92.2percent of the 15,392 installed sensors, with the remainder supplied by CiS.

  11. The Silicon Microstrip Sensors of the ATLAS SemiConductor Tracker

    CERN Document Server

    Ahmad, A; Allport, P P; Alonso, J; Andricek, L; Apsimon, R J; Barr, A J; Bates, R L; Beck, G A; Bell, P J; Belymam, A; Benes, J; Berg, C M; Bernabeu, J; Bethke, S; Bingefors, N; Bizzell, J P; Bohm, J; Brenner, R; Brodbeck, T J; Bruckman De Renstrom, P; Buttar, C M; Campbell, D; Carpentieri, C; Carter, A A; Carter, J R; Charlton, D G; Casse, G-L; Chilingarov, A; Cindro, V; Ciocio, A; Civera, J V; Clark, A G; Colijn, A-P; Costa, M J; Dabrowski, W; Danielsen, K M; Dawson, I; Demirkoz, B; Dervan, P; Dolezal, Z; Dorholt, O; Duerdoth, I P; Dwuznik, M; Eckert, S; Ekelöf, T; Eklund, L; Escobar, C; Fasching, D; Feld, L; Ferguson, D P S; Ferrere, D; Fortin, R; Foster, J M; Fox, H; French, R; Fromant, B P; Fujita, K; Fuster, J; Gadomski, S; Gallop, B J; Garcia, C; Garcia-Navarro, J E; Gibson, M D; Gonzalez, S; Gonzalez-Sevilla, S; Goodrick, M J; Gornicki, E; Green, C; Greenall, A; Grigson, C; Grillo, A A; Grosse-Knetter, J; Haber, C; Handa, T; Hara, K; Harper, R S; Hartjes, F G; Hashizaki, T; Hauff, D; Hessey, N P; Hill, J C; Hollins, T I; Holt, S; Horazdovsky, T; Hornung, M; Hovland, K M; Hughes, G; Huse, T; Ikegami, Y; Iwata, Y; Jackson, J N; Jakobs, K; Jared, R C; Johansen, L G; Jones, R W L; Jones, T J; de Jong, P; Joseph, J; Jovanovic, P; Kaplon, J; Kato, Y; Ketterer, C; Kindervaag, I M; Kodys, P; Koffeman, E; Kohriki, T; Kohout, Z; Kondo, T; Koperny, S; van der Kraaij, E; Kral, V; Kramberger, G; Kudlaty, J; Lacasta, C; Limper, M; Linhart, V; Llosa, G; Lozano, M; Ludwig, I; Ludwig, J; Lutz, G; Macpherson, A; McMahon, S J; Macina, D; Magrath, C A; Malecki, P; Mandic, I; Marti-Garcia, S; Matsuo, T; Meinhardt, J; Mellado, B; Mercer, I J; Mikestikova, M; Mikuz, M; Minano, M; Mistry, J; Mitsou, V; Modesto, P; Mohn, B; Molloy, S D; Moorhead, G; Moraes, A; Morgan, D; Morone, M C; Morris, J; Moser, H-G; Moszczynski, A; Muijs, A J M; Nagai, K; Nakamura, Y; Nakano, I; Nicholson, R; Niinikoski, T; Nisius, R; Ohsugi, T; O'Shea, V; Oye, O K; Parzefall, U; Pater, J R; Pernegger, H; Phillips, P W; Posisil, S; Ratoff, P N; Reznicek, P; Richardson, J D; Richter, R H; Robinson, D; Roe, S; Ruggiero, G; Runge, K; Sadrozinski, H F W; Sandaker, H; Schieck, J; Seiden, A; Shinma, S; Siegrist, J; Sloan, T; Smith, N A; Snow, S W; Solar, M; Solberg, A; Sopko, B; Sospedra, L; Spieler, H; Stanecka, E; Stapnes, S; Stastny, J; Stelzer, F; Stradling, A; Stugu, B; Takashima, R; Tanaka, R; Taylor, G; Terada, S; Thompson, R J; Titov, M; Tomeda, Y; Tovey, D R; Turala, M; Turner, P R; Tyndel, M; Ullan, M; Unno, Y; Vickey, T; Vos, M; Wallny, R; Weilhammer, P; Wells, P S; Wilson, J A; Wolter, M; Wormald, M; Wu, S L; Yamashita, T; Zontar, D; Zsenei, A

    2007-01-01

    This paper describes the AC-coupled, single-sided, p-in-n silicon microstrip sensors used in the SemiConductor Tracker (SCT) of the ATLAS experiment at the CERN Large Hadron Collider (LHC). The sensor requirements, specifications and designs are discussed, together with the qualification and quality assurance procedures adopted for their production. The measured sensor performance is presented, both initially and after irradiation to the fluence anticipated after 10 years of LHC operation. The sensors are now successfully assembled within the detecting modules of the SCT, and the SCT tracker is completed and integrated within the ATLAS Inner Detector. Hamamatsu Photonics Ltd supplied 92.2% of the 15,392 installed sensors, with the remainder supplied by CiS.

  12. The silicon microstrip sensors of the ATLAS semiconductor tracker

    International Nuclear Information System (INIS)

    ATLAS SCT Collaboration; Spieler, Helmuth G.

    2007-01-01

    This paper describes the AC-coupled, single-sided, p-in-n silicon microstrip sensors used in the Semiconductor Tracker (SCT) of the ATLAS experiment at the CERN Large Hadron Collider (LHC). The sensor requirements, specifications and designs are discussed, together with the qualification and quality assurance procedures adopted for their production. The measured sensor performance is presented, both initially and after irradiation to the fluence anticipated after 10 years of LHC operation. The sensors are now successfully assembled within the detecting modules of the SCT, and the SCT tracker is completed and integrated within the ATLAS Inner Detector. Hamamatsu Photonics Ltd. supplied 92.2percent of the 15,392 installed sensors, with the remainder supplied by CiS

  13. Performance of various quantum-key-distribution systems using 1.55-μm up-conversion single-photon detectors

    International Nuclear Information System (INIS)

    Diamanti, Eleni; Takesue, Hiroki; Honjo, Toshimori; Inoue, Kyo; Yamamoto, Yoshihisa

    2005-01-01

    We compare the performance of various quantum-key-distribution (QKD) systems using a single-photon detector, which combines frequency up-conversion in a periodically poled lithium niobate waveguide and a silicon avalanche photodiode (APD). The comparison is based on the secure communication rate as a function of distance for three QKD protocols: the Bennett-Brassard 1984, the Bennett-Brassard-Mermin 1992, and the coherent differential-phase-shift keying protocols. We show that the up-conversion detector allows for higher communication rates and longer communication distances than the commonly used InGaAs/InP APD for all three QKD protocols

  14. Photodynamics and Physics behind Tunable Solid-State Lasers

    Science.gov (United States)

    1991-02-28

    complete photodetector assembly for optical lab research. The Hamamatsu HC220 is an economical tool ready to go to work on the bench or in the...was measured imerterometricaliy wrrne mpu ; and output energies were also monitorec. Figure 1 shows a schematic layout of me appa- ratus. A NdrYAG

  15. Characterization of large-area photomultipliers under low magnetic fields: Design and performance of the magnetic shielding for the Double Chooz neutrino experiment

    International Nuclear Information System (INIS)

    Calvo, E.; Cerrada, M.; Fernandez-Bedoya, C.; Gil-Botella, I.; Palomares, C.; Rodriguez, I.; Toral, F.; Verdugo, A.

    2010-01-01

    A precise quantitative measurement of the effect of low magnetic fields in Hamamatsu R7081 photomultipliers has been performed. These large-area photomultipliers will be used in the Double Chooz neutrino experiment. A magnetic shielding has been developed for these photomultipliers. Its design and performance is also reported in this paper.

  16. The construction of the Black dance/African Peoples' dance section in Britain: Issues arising for the conceptualisation of related choreographic and dance practices

    OpenAIRE

    Adewole, Funmi

    2016-01-01

    This chapter will discuss the construction of the Black dance/African Peoples’ Dance sector (APD) in Britain in the 1990s. The debate about the definition of the terms Black dance and African peoples’ dance is shown to be part and parcel of the quest for appropriate infrastructure to sustain the work of black dancers and those using African and Diasporan dance forms and aesthetics in their productions. I argue therefore that a fuller understanding of this field of practice can only be gained ...

  17. Characterization of the dextran-binding domain in the glucan-binding protein C of Streptococcus mutans.

    Science.gov (United States)

    Takashima, Y; Fujita, K; Ardin, A C; Nagayama, K; Nomura, R; Nakano, K; Matsumoto-Nakano, M

    2015-10-01

    Streptococcus mutans produces multiple glucan-binding proteins (Gbps), among which GbpC encoded by the gbpC gene is known to be a cell-surface-associated protein involved in dextran-induced aggregation. The purpose of the present study was to characterize the dextran-binding domain of GbpC using bioinformatics analysis and molecular techniques. Bioinformatics analysis specified five possible regions containing molecular binding sites termed GB1 through GB5. Next, truncated recombinant GbpC (rGbpC) encoding each region was produced using a protein expression vector and five deletion mutant strains were generated, termed CDGB1 through CDGB5 respectively. The dextran-binding rates of truncated rGbpC that included the GB1, GB3, GB4 and GB5 regions in the upstream sequences were higher than that of the construct containing GB2 in the downstream region. In addition, the rates of dextran-binding for strains CDGB4 and CD1, which was entire gbpC deletion mutant, were significantly lower than for the other strains, while those of all other deletion mutants were quite similar to that of the parental strain MT8148. Biofilm structures formed by CDGB4 and CD1 were not as pronounced as that of MT8148, while those formed by other strains had greater density as compared to that of CD1. Our results suggest that the dextran-binding domain may be located in the GB4 region in the interior of the gbpC gene. Bioinformatics analysis is useful for determination of functional domains in many bacterial species. © 2015 The Society for Applied Microbiology.

  18. Evaluation Of Silicon Diodes As IN-SITU Cryogenic Field Emission Detectors For SRF Cavity Development

    International Nuclear Information System (INIS)

    Palczewski, Ari; Geng, Rongli

    2012-01-01

    We performed in-situ cryogenic testing of four silicon diodes as possible candidates for field emission (FE) monitors of superconducting radio frequency (SRF) cavities during qualification testing and in accelerator cryo-modules. We evaluated diodes from 2 companies - from Hamamatsu corporation model S1223-01; and from OSI Optoelectronics models OSD35-LR-A, XUV-50C, and FIL-UV20. The measurements were done by placing the diodes in superfluid liquid helium near the top of a field emitting 9-cell cavity during its vertical test. For each diode, we will discuss their viability as a 2K cryogenic detector for FE mapping of SRF cavities and the directionality of S1223-01 in such environments. We will also present calibration curves between the diodes and JLab's standard radiation detector placed above the Dewar's top plate.

  19. Uso da uréia como suplemento protéico na dieta de doadoras e receptoras de embriões bovinos Urea as a protein supplementation in the diet of bovine embryo donors and recipients

    Directory of Open Access Journals (Sweden)

    Amílcar Gasperin Barreto

    2003-02-01

    Full Text Available Doze doadoras de embriões Bos indicus da raça Nelore foram confinadas recebendo 25 kg de silagem de milho e 2,5 kg de três diferentes suplementos concentrados ao dia. O ingrediente protéico ofertado foi SOJA (S, SOJA+URÉIA (S+U e URÉIA (U. Após período de 20 dias, as doadoras foram superovuladas e seus embriões colhidos e cultivados in vitro até eclosão. Não se observou diferença entre tratamentos com relação ao número total de estruturas colhidas (4,17; 8,42 e 7,00, número de embriões viáveis (2,25; 3,50 e 4,33, de ovócitos (1,42; 3,92 e 1,08 ou de estruturas degeneradas (0,5; 1,0 e 1,83, bem como na taxa de eclosão in vitro (81,48%; 78,57% e 84,62% nos grupos S, S+U e U, respectivamente. As 66 receptoras de embriões foram mantidas em pasto de Braquiaria decumbens com 1,25 kg de suplemento concentrado dividido em três tratamentos semelhantes aos recebidos pelas doadoras. Após 37 dias, embriões foram descongelados e transferidos em grupos S, S+U e U. Não se observaram diferenças na taxa de gestação aos 30 dias (25; 28 e 28,57% e aos 60 dias (16,67; 28 e 25%, nos grupos S, S+U e U, respectivamente. Tendo em vista que não foi observado efeito deletério na qualidade dos embriões, taxa de eclosão e fertilidade das receptoras, pode-se concluir que a uréia se mostrou como uma opção na substituição do farelo de soja em concentrados na suplementação de doadoras e receptoras de embriões.Twelve Bos indicus (Nellore embryo donors were confined receiving 25 kg maize silage and 2.5 kg concentrate supplement per day. The proteic supplements used were SOYA (S, SOYA+UREA (S+U and UREA (U. After 20 day, embryo donors were superovulated and their embryos collected and cultivated in vitro until eclosion. There was no significant statistical difference between the three groups in total number of structures collected (4.17, 8.42 and 7.00, number of viable embryos (2.25, 3.50 and 4.33, oocytes (1.42, 3.92 and 1.08 or

  20. Experimental studies on using silicon photodiode as read-out component of CsI(Tl) crystal

    International Nuclear Information System (INIS)

    He Jingtang; Chen Duanbao; Li Zuhao; Mao Yufang; Dong Xiaoli

    1996-01-01

    Experimental studies on using silicon photodiode as the read-out component of CsI(Tl) crystal are reported. The read-out properties of two different types of silicon photodiode produced by Hamamatsu were measured, including relations between energy resolution and bias, shaping time, sensitive area of photodiode and the dimension of the crystal

  1. The role of a preliminary PGY-3 in general surgery training.

    Science.gov (United States)

    Tarpley, Margaret J; Van Way, Charles; Friedell, Mark; Deveney, Karen; Farley, David; Mellinger, John; Scott, Bradford; Tarpley, John

    2014-01-01

    Even before the preliminary postgraduate year (PGY)-3 was eliminated from surgical residency, it had become increasingly difficult to fill general surgery PGY-4 vacancies. This ongoing need prompted the Association of Program Directors in Surgery (APDS) leadership to form a task force to study the possibility of requesting the restoration of the preliminary PGY-3 to Accreditation Council for Graduate Medical Education-approved general surgery residency programs. The task force conducted a 10-year review of the APDS list serve to ascertain the number of advertised PGY-4 open positions. Following the review of the list serve, the task force sent IRB-approved electronic REDCap surveys to 249 program directors (PDs) in general surgery. The list serve review revealed more than 230 requests for fourth-year residents, a number that most likely underestimates the need, as such, vacancies are not always advertised through the APDS. A total of 119 PDs (~48%) responded. In the last 10 years, these 119 programs needed an average of 2 PGY-4 residents (range: 0-8), filled 1.3 positions (range: 0-7), and left a position unfilled 1.3 times (range: 0-7). Methods for finding PGY-4 residents included making personal contacts with other PDs (52), posting on the APDS Topica List Serve (47), and using the APDS Web site for interested candidates on residency and fellowship job listings (52). Reasons for needing a PGY-4 resident included residents leaving the program (82), extra laboratory years (39), remediation (31), and approved program expansion (21), as well as other issues. Satisfaction scores for the added PGY-4 residents were more negative (43) than positive (30). Problems ranged from lack of preparation to professionalism. When queried as to an optimal number of preliminary residents needed nationally at the PGY-3 level, responses varied from 0 to 50 (34 suggested 10). The survey of PDs supports the need for the reintroduction of a limited number of Accreditation Council for

  2. Correction of differential renal function for asymmetric renal area ratio in unilateral hydronephrosis.

    Science.gov (United States)

    Aktaş, Gul Ege; Sarıkaya, Ali

    2015-11-01

    Children with unilateral hydronephrosis are followed up with anteroposterior pelvic diameter (APD), hydronephrosis grade, mercaptoacetyltriglycine (MAG-3) drainage pattern and differential renal function (DRF). Indeterminate drainage preserved DRF in higher grades of hydronephrosis, in some situations, complicating the decision-making process. Due to an asymmetric renal area ratio, falsely negative DRF estimations can result in missed optimal surgery times. This study was designed to assess whether correcting the DRF estimation according to kidney area could reflect the clinical situation of a hydronephrotic kidney better than a classical DRF calculation, concurrently with the hydronephrosis grade, APD and MAG-3 drainage pattern. We reviewed the MAG-3, dimercaptosuccinic acid (DMSA) scans and ultrasonography (US) of 23 children (6 girls, 17 boys, mean age: 29 ± 50 months) with unilateral hydronephrosis. MAG-3 and DMSA scans were performed within 3 months (mean 25.4 ± 30.7 days). The closest US findings (mean 41.5 ± 28.2 days) were used. DMSA DRF estimations were obtained using the geometric mean method. Secondary calculations were performed to correct the counts (the total counts divided by the number of pixels in ROI) according to kidney area. The renogram patterns of patients were evaluated and separated into subgroups. The visual assessment of DMSA scans was noted and the hydronephrotic kidney was classified in comparison to the normal contralateral kidney's uptake. The correlations of the DRF values of classical and area-corrected methods with MAG-3 renogram patterns, the visual classification of DMSA scan, the hydronephrosis grade and the APD were assessed. DRF estimations of two methods were statistically different (p: 0.001). The categories of 12 hydronephrotic kidneys were changed. There were no correlations between classical DRF estimations and the hydronephrosis grade, APD, visual classification of the DMSA scan and uptake evaluation. The DRF

  3. A magnetic resonance spectroscopy study of antisocial behaviour disorder, psychopathy and violent crime among military conscripts.

    Science.gov (United States)

    Basoglu, Cengiz; Semiz, Umit; Oner, Ozgur; Gunay, Huseyin; Ebrinc, Servet; Cetin, Mesut; Sildiroglu, Onur; Algul, Ayhan; Ates, Alpay; Sonmez, Guner

    2008-04-01

    Prefrontal and/or temporo-limbic abnormalities associated with antisocial personality disorder (APD), high psychopathy scores and violent behaviours can readily be evaluated by neuroimaging methods. In this study, we compared the brain metabolites in adult male military conscripts with APD, high psychopathy scores and serious violent crimes (n = 15) with age- and educational-level-matched healthy controls (n = 15) by means of magnetic resonance spectroscopy. All cases were diagnosed by means of the Diagnostic Statistical Manual-IV APD module of the Structured Clinical Interview for DSM III-R Axis II Disorders (SCID-II) semistructured questionnaire in Turkish. The psychopathy scores were evaluated by means of the Hare Psychopathy Checklist-Revised translated into Turkish (PCL-R). PCL-R is a 20-item, reliable and valid instrument for assessment of psychopathy, both in categorical and dimensional natures. All patients had a total score of 29 (of possible 40) or higher from PCL-R, indicating a high degree of psychopathy. Our results showed no significant differences in ratio of N-acetyl aspartate (NAA), creatine (Cr) and choline-related compounds in the right dorsolateral prefrontal cortex, anterior cingulate cortex (ACC) and amygdala-hippocampus regions of cases compared with controls. ACC NAA/Cr was significantly negatively correlated with both the PCL-R total score and the PCL-R factor I score (interpersonal/affective problems) among the cases. As ACC plays an important role in decision-making and emotional information processing, we postulate that the lower NAA/Cr ratio, suggesting impaired neural integrity, may increase the severity of interpersonal/affective problems of the psychopathy factor in male subjects exhibiting APD, high psychopathy overall scores and violent crimes.

  4. Longitudinal effects of dysfunctional perfectionism and avoidant personality style on postpartum mental disorders: Pathways through antepartum depression and anxiety.

    Science.gov (United States)

    Oddo-Sommerfeld, Silvia; Hain, Sarah; Louwen, Frank; Schermelleh-Engel, Karin

    2016-02-01

    There is first evidence that some personality characteristics raise the risk of postpartum depression (PPD). The present longitudinal study investigates whether dysfunctional perfectionism and avoidant personality style predict PPD, postpartum anxiety (PPA) and bonding impairment (BI) directly or indirectly through antepartum anxiety (APA) and antepartum depression (APD). Pregnant women were recruited in two obstetric departments in Germany. The assessment occurred at two measurement time points: In the third trimester of pregnancy (N=297) and twelve weeks postpartum (N=266). Six questionnaires were administered during pregnancy: perfectionism, personality styles, anxiety, and depression. Postpartum, data on PPA, PPD and BI were collected. We conducted two path analyses in order to examine direct and indirect effects of the two personality characteristics on postpartum disorders. Testing for direct effects of dysfunctional perfectionism and avoidant personality style on PPD, PPA, and BI did not yield significant results. Instead, significant indirect effects were found: PPD, PPA, and BI were influenced indirectly by dysfunctional perfectionism and avoidant personality style via APD and APA. This model explained high portions of the variance of PPD, PPA, and impaired bonding. Each of the two personality characteristics explained a unique part of the outcome measures. The influence on BI was mediated by PPD. APD affected PPD and PPA more strongly than APA. Path models with manifest (observed) variables may lead to measurement errors. Self-rating questionnaires may raise the problem of social desirability. Dysfunctional perfectionism and avoidant personality style are significant risk factors for PPD, PPA, and BI. Screenings of both variables, as well as of APA and APD, which mediated the effect of personality traits on postpartum syndromes, are necessary. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Theory of the development of alternans in the heart during controlled diastolic interval pacing

    Science.gov (United States)

    Otani, Niels F.

    2017-09-01

    The beat-to-beat alternation in action potential durations (APDs) in the heart, called APD alternans, has been linked to the development of serious cardiac rhythm disorders, including ventricular tachycardia and fibrillation. The length of the period between action potentials, called the diastolic interval (DI), is a key dynamical variable in the standard theory of alternans development. Thus, methods that control the DI may be useful in preventing dangerous cardiac rhythms. In this study, we examine the dynamics of alternans during controlled-DI pacing using a series of single-cell and one-dimensional (1D) fiber models of alternans dynamics. We find that a model that combines a so-called memory model with a calcium cycling model can reasonably explain two key experimental results: the possibility of alternans during constant-DI pacing and the phase lag of APDs behind DIs during sinusoidal-DI pacing. We also find that these results can be replicated by incorporating the memory model into an amplitude equation description of a 1D fiber. The 1D fiber result is potentially concerning because it seems to suggest that constant-DI control of alternans can only be effective over only a limited region in space.

  6. A new avalanche photo diode based readout for the crystal barrel calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Urban, Martin [Helmholtz-Institut fuer Strahlen- und Kernphysik, Nussallee 14-16, 53115 Bonn (Germany); Collaboration: CBELSA/TAPS-Collaboration

    2015-07-01

    The CBELSA/TAPS experiment at ELSA has proven successful in the measurement of double polarization observables in meson photoproduction off protons and neutrons. To be able to measure purely neutral reactions on a polarized neutron target with high efficiency, the main calorimeter consisting of 1320 CsI(Tl) crystals has to be integrated into the first level trigger. Key requirement to achieve this goal is an exchange of the existing PIN photo diode by a new avalanche photo diode (APD) readout. The main advantage of the new readout system is that it will provide timing information which allows a fast trigger signal. The energy resolution will remain compatible to the previous system. Besides the development of automated test routines for the front end electronics, the characterization of all APDs was successfully accomplished in Bonn. After tests with a 3 x 3 CsI(Tl) crystal matrix at the tagged photon beam facilities at ELSA and MAMI the first half of the Crystal Barrel was upgraded in 2014. This talk shows the result of the latest test measurements including the gain stabilization of the new APD readout electronics and presents the progress of the ongoing upgrade.

  7. Low-Noise Free-Running High-Rate Photon-Counting for Space Communication and Ranging

    Science.gov (United States)

    Lu, Wei; Krainak, Michael A.; Yang, Guan; Sun, Xiaoli; Merritt, Scott

    2016-01-01

    We present performance data for low-noise free-running high-rate photon counting method for space optical communication and ranging. NASA GSFC is testing the performance of two types of novel photon-counting detectors 1) a 2x8 mercury cadmium telluride (HgCdTe) avalanche array made by DRS Inc., and a 2) a commercial 2880-element silicon avalanche photodiode (APD) array. We successfully measured real-time communication performance using both the 2 detected-photon threshold and logic AND-gate coincidence methods. Use of these methods allows mitigation of dark count, after-pulsing and background noise effects without using other method of Time Gating The HgCdTe APD array routinely demonstrated very high photon detection efficiencies (50) at near infrared wavelength. The commercial silicon APD array exhibited a fast output with rise times of 300 ps and pulse widths of 600 ps. On-chip individually filtered signals from the entire array were multiplexed onto a single fast output. NASA GSFC has tested both detectors for their potential application for space communications and ranging. We developed and compare their performances using both the 2 detected photon threshold and coincidence methods.

  8. Clarifying the Role of Defensive Reactivity Deficits in Psychopathy and Antisocial Personality Using Startle Reflex Methodology

    Science.gov (United States)

    Vaidyanathan, Uma; Hall, Jason R.; Patrick, Christopher J.; Bernat, Edward M.

    2010-01-01

    Prior research has demonstrated deficits in defensive reactivity (indexed by potentiation of the startle blink reflex) in psychopathic individuals. However, the basis of this association remains unclear, as diagnostic criteria for psychopathy encompass two distinct phenotypic components that may reflect differing neurobiological mechanisms – an affective-interpersonal component, and an antisocial deviance component. Likewise, the role of defensive response deficits in antisocial personality disorder (APD), a related but distinct syndrome, remains to be clarified. The current study examined affective priming deficits in relation to factors of psychopathy and symptoms of APD using startle reflex methods in 108 adult male prisoners. Deficits in blink reflex potentiation during aversive picture viewing were found in relation to the affective-interpersonal (Factor 1) component of psychopathy, and to a lesser extent in relation to the antisocial deviance (Factor 2) component of psychopathy and symptoms of APD—but only as a function of their overlap with affective-interpersonal features of psychopathy. These findings provide clear evidence that deficits in defensive reactivity are linked specifically to the affective-interpersonal features of psychopathy, and not the antisocial deviance features represented most strongly in APD. PMID:20973594

  9. Single-photon semiconductor photodiodes for distributed optical fiber sensors: state of the art and perspectives

    Science.gov (United States)

    Ripamonti, Giancarlo; Lacaita, Andrea L.

    1993-03-01

    The extreme sensitivity and time resolution of Geiger-mode avalanche photodiodes (GM- APDs) have already been exploited for optical time domain reflectometry (OTDR). Better than 1 cm spatial resolution in Rayleigh scattering detection was demonstrated. Distributed and quasi-distributed optical fiber sensors can take advantage of the capabilities of GM-APDs. Extensive studies have recently disclosed the main characteristics and limitations of silicon devices, both commercially available and developmental. In this paper we report an analysis of the performance of these detectors. The main characteristics of GM-APDs of interest for distributed optical fiber sensors are briefly reviewed. Command electronics (active quenching) is then introduced. The detector timing performance sets the maximum spatial resolution in experiments employing OTDR techniques. We highlight that the achievable time resolution depends on the physics of the avalanche spreading over the device area. On the basis of these results, trade-off between the important parameters (quantum efficiency, time resolution, background noise, and afterpulsing effects) is considered. Finally, we show first results on Germanium devices, capable of single photon sensitivity at 1.3 and 1.5 micrometers with sub- nanosecond time resolution.

  10. Intrinsic and Antipsychotic Drug-Induced Metabolic Dysfunction in Schizophrenia

    Directory of Open Access Journals (Sweden)

    Zachary Freyberg

    2017-07-01

    Full Text Available For decades, there have been observations demonstrating significant metabolic disturbances in people with schizophrenia including clinically relevant weight gain, hypertension, and disturbances in glucose and lipid homeostasis. Many of these findings pre-date the use of antipsychotic drugs (APDs which on their own are also strongly associated with metabolic side effects. The combination of APD-induced metabolic changes and common adverse environmental factors associated with schizophrenia have made it difficult to determine the specific contributions of each to the overall metabolic picture. Data from drug-naïve patients, both from the pre-APD era and more recently, suggest that there may be an intrinsic metabolic risk associated with schizophrenia. Nevertheless, these findings remain controversial due to significant clinical variability in both psychiatric and metabolic symptoms throughout patients' disease courses. Here, we provide an extensive review of classic and more recent literature describing the metabolic phenotype associated with schizophrenia. We also suggest potential mechanistic links between signaling pathways associated with schizophrenia and metabolic dysfunction. We propose that, beyond its symptomatology in the central nervous system, schizophrenia is also characterized by pathophysiology in other organ systems directly related to metabolic control.

  11. A transimpedance amplifier for excess noise measurements of high junction capacitance avalanche photodiodes

    International Nuclear Information System (INIS)

    Green, James E; David, John P R; Tozer, Richard C

    2012-01-01

    This paper reports a novel and versatile system for measuring excess noise and multiplication in avalanche photodiodes (APDs), using a bipolar junction transistor based transimpedance amplifier front-end and based on phase-sensitive detection, which permits accurate measurement in the presence of a high dark current. The system can reliably measure the excess noise factor of devices with capacitance up to 5 nF. This system has been used to measure thin, large area Si pin APDs and the resulting data are in good agreement with measurements of the same devices obtained from a different noise measurement system which will be reported separately. (paper)

  12. Ultralow noise midwave infrared InAs-GaSb strain layer superlattice avalanche photodiode

    International Nuclear Information System (INIS)

    Mallick, Shubhrangshu; Banerjee, Koushik; Ghosh, Siddhartha; Plis, Elena; Rodriguez, Jean Baptiste; Krishna, Sanjay; Grein, Christoph

    2007-01-01

    Eye-safe midwavelength infrared InAs-GaSb strain layer superlattice p + -n - -n homojunction avalanche photodiodes (APDs) grown by solid source molecular beam epitaxy were fabricated and characterized. Maximum multiplication gain of 1800 was measured at -20 V at 77 K. Excess noise factors between 0.8 and 1.2 were measured up to gain of 300. Gain of 200 was measured at 120 K. Exponential nature of the gain as a function of reverse bias along with low excess noise factor at higher gain confirms single carrier electron-only impact ionization in the avalanche regime. Decrease in the multiplication gain at higher temperatures correlates with standard APD characteristics

  13. Comparative study of new 130mm diameter fast photomultipliers for neutron detectors

    International Nuclear Information System (INIS)

    Moszynski, M.; Costa, G.J.; Guillaume, G.; Heusch, B.; Huck, A.; Mouatassim, S.

    1991-01-01

    The present paper is a summary of the test measurements carried out using new 130 mm diameter fast photomultiplier tubes manufactured by Philips (France), EMI (England) and Hamamatsu (Japan), along with a comparison to the results obtained with the well known XP 2041 Philips model. These tubes will be used in large size neutron detectors

  14. Calibration, testing, commissioning and first data of ALFA at LHC

    CERN Document Server

    Jakobsen, S; The ATLAS collaboration

    2011-01-01

    The ALFA detector system (Absolute Luminosity For ATLAS) aims for measuring the absolute LHC luminosity with high precision by using pp-scattering under small angles. Scintillating fibers tracking detectors are positioned 240 m from LHC interaction point 1 inside Roman Pots at millimeter distance from the LHC beam axis. The detectors consist of layers of 64 scintillating square fibers of 500 µm size in a U-V configuration. The layers are staggered 10 times to improve the spatial resolution to about 30 micrometers. A total of 11680 scintillating fibers are read out on the 8 ALFA detectors through 184 Multi Anode Photomultiplier Tubes, MAPMTs, of type Hamamatsu R7600-00-M64, 64 channels. Each detector has dedicated scintillating trigger tiles read out by 8 mm Hamamatsu Photomultiplier Tubes (R7400P and R9880U-110) via clear fibers. The gain of the MAPMTs differs up to a factor 3 inside a MAPMT and an additional factor 2 between different MAPMTs. For compensation, ALFA has developed a front-end electronic based...

  15. A novel high resolution, high sensitivity SPECT detector for molecular imaging of cardiovascular diseases

    Science.gov (United States)

    Cusanno, F.; Argentieri, A.; Baiocchi, M.; Colilli, S.; Cisbani, E.; De Vincentis, G.; Fratoni, R.; Garibaldi, F.; Giuliani, F.; Gricia, M.; Lucentini, M.; Magliozzi, M. L.; Majewski, S.; Marano, G.; Musico, P.; Musumeci, M.; Santavenere, F.; Torrioli, S.; Tsui, B. M. W.; Vitelli, L.; Wang, Y.

    2010-05-01

    Cardiovascular diseases are the most common cause of death in western countries. Understanding the rupture of vulnerable atherosclerotic plaques and monitoring the effect of innovative therapies of heart failure is of fundamental importance. A flexible, high resolution, high sensitivity detector system for molecular imaging with radionuclides on small animal models has been designed for this aim. A prototype has been built using tungsten pinhole and LaBr3(Ce) scintillator coupled to Hamamatsu Flat Panel PMTs. Compact individual-channel readout has been designed, built and tested. Measurements with phantoms as well as pilot studies on mice have been performed, the results show that the myocardial perfusion in mice can be determined with sufficient precision. The detector will be improved replacing the Hamamatsu Flat Panel with Silicon Photomultipliers (SiPMs) to allow integration of the system with MRI scanners. Application of LaBr3(Ce) scintillator coupled to photosensor with high photon detection efficiency and excellent energy resolution will allow dual-label imaging to monitor simultaneously the cardiac perfusion and the molecular targets under investigation during the heart therapy.

  16. Evaluation of flat panel PMT for gamma ray imaging

    International Nuclear Information System (INIS)

    Pani, R.; Cinti, M.N.; Pellegrini, R.; Trotta, C.; Trotta, G.; Montani, L.; Ridolfi, S.; Garibaldi, F.; Scafe, R.; Belcari, N.; Del Guerra, A.

    2003-01-01

    The first position sensitive PMT, Hamamatsu R2486, developed in 1985, represented a strong technological advance for gamma-ray imaging. Hamamatsu H8500 Flat Panel PMT is the last generation position sensitive PMT: extremely compact with 2 in. active area. Its main features are: minimum peripheral dead zone (1 mm) and height of 12 mm. It was designed to be assembled in array to cover large detection area. It can represent a technical revolution for many applications in the field of gamma-ray imaging as for example nuclear medicine. This tube is based on metal channel dynode for charge multiplication and 8x8 anodes for charge collection and position calculation. In this paper we present a preliminary evaluation of the imaging performances addressed to nuclear medicine application. To this aim we have taken into account two different electronic readouts: resistive chain with Anger Camera principle and multianode readout. Flat panel PMT was coupled to CsI(Tl) and NaI(Tl) scintillation arrays. The results were also compared with the first generation PSPMT

  17. Comparison of the Multi-anode PMTs with the old HF PMTs by Studying the Collision Data

    CERN Document Server

    Oz, Yavuz

    2013-01-01

    The Hadron Forward (HF) calorimeter of the CMS detector improves jet detection and missing transverse energy resolution in the high pseudorapidity range. HF employs photomultiplier tubes (PMT) that measure the Cerenkov light emitted by shower products in quartz fibers. Stray muons that hit a PMT window create high energy events that are difficult to reject. To alleviate this problem, the PMTs installed in the CMS will be replaced with those of better performance. From among various candidate PMTs, quad-anode Hamamatsu R7600U-200-M4 were chosen to replace the single-anode Hamamatsu R7525HA PMTs. The quad-anode PMTs offer the possibility to reject window events at the hardware level; muons hitting the window are localized to a single anode, while real events illuminate all four anodes. In 2011, eight such PMTs were installed in the readout boxes corresponding to the coordinates $i\\phi=67$, $i\\eta=29,30,31,32$, which get very few hits on account of their location. The purpose of this thesis is to compare the res...

  18. Computer Program for Vibration Prediction of Fighter Aircraft Equipments

    Science.gov (United States)

    1977-11-01

    Y,*70q, X, S VJPPF 768 2? c ,l0 -1-qv** o, ~7 Aljl VIPRF 26q OTNT I,(TPL A NE(T),T=I ,),JFLITE,IMOPLT VIPPF 770 F,7 T(1rRp, 2Y, 0FSPITION OARD*/2 0 Y...VTPPF 2261 VIPPF 2262 VTPPF 2267 H-r,< Ww P D "lrgFPTTT O ,l, rAPD WAS RSA VIPRF 2264 17 VTPPF 22E5 1I f =ILT =2(1 1iP(I.WE.IS NnL.An..NF.IIU r

  19. Epitaxial grown InP quantum dots on a GaAs buffer realized on GaP/Si(001) templates

    Energy Technology Data Exchange (ETDEWEB)

    Hartwig, Walter; Wiesner, Michael; Koroknay, Elisabeth; Paul, Matthias; Jetter, Michael; Michler, Peter [Institut fuer Halbleiteroptik und Funktionelle Grenzflaechen und Research Center SCoPE, Universitaet Stuttgart, Allmandring 3, 70569 Stuttgart (Germany)

    2013-07-01

    The increasing necessity of higher computational capacity and security in the information technology requires originally technical solutions, which today's standard microelectronics, as their technical limits are close, can't provide anymore. One way out offers the integration of III-V semiconductor photonics with low-dimensional structures in current CMOS technology, enabling on-chip quantum optical applications, like quantum cryptography or quantum computing. Challenges in the heteroepitaxy of III-V semiconductors and silicon are the mismatches in material properties of the both systems. Defects, like dislocations and anti-phase domains (APDs), inhibit the monolithic integration of III-V semiconductor on Si. We present the growth of a thin GaAs buffer on CMOS-compatible oriented Si(001) by metal-organic vapor-phase epitaxy. To circumvent the forming APDs in the GaAs buffer a GaP on Si template (provided by NAsP{sub III/V} GmbH) was used. The dislocation density was then reduced by integrating several layers of InAs quantum dots in the GaAs buffer to bend the threading misfit dislocations. On top of this structure we grew InP quantum dots embedded in a Al{sub x}Ga{sub 1-x}InP composition and investigated the photoluminescence properties.

  20. Photokeratoconjunctivitis Symptoms among Informal Welding Operators in North Samarinda, Indonesia

    Directory of Open Access Journals (Sweden)

    Iwan Muhamad Ramdan

    2017-08-01

    Sektor informal telah berkontribusi terhadap perekonomian nasional, namun praktik kesehatan dan keselamatan kerja pada sektor ini masih belum memuaskan. Salah satu usaha sektor informal yang banyak dijumpai di Samarinda Utara adalah usaha pengelasan dengan potensi bahaya utama paparan sinar ultraviolet yang dapat menyebabkan photokeratoconjunctivitis. Penelitian ini bertujuan menginvestigasi kejadian photokeratoconjunctivitis dan faktor yang memengaruhinya pada operator las informal di Kelurahan Samarinda Utara. Penelitian cross-sectional telah dilakukan terhadap 40 responden pada bulan Maret sampai November 2016. Pengumpulan data menggunakan UV detector meter, clamp meter, dan kuesioner. Analisis data menggunakan chi-square, Pearson’s correlation product moment, dan multiple linear regression. Lima puluh persen responden mengalami gejala photokeratoconjunctivitis. Alat pelindung diri (APD (p=0,004, durasi paparan UV (0,056, pengetahuan tentang kesehatan, dan keselamatan kerja (K3 (p=0,055 dan jumlah hari kerja (p=0,001 berhubungan signifikan dengan kejadian photokeratoconjunctivitis. Lokasi kerja (p=0,244, tingkat pendidikan (p=0,680, usia (0,167, intensitas radiasi UV (p=0,206, dan kuat arus las (p=0,085 tidak berhubungan dengan gejala photokeratoconjunctivitis. Simpulan, gejala photokeratoconjunctivitis dipengaruhi oleh penggunaan APD, durasi paparan UV, pengetahuan K3, dan jumlah hari kerja. Faktor yang paling dominan memengaruhi gejala photokeratoconjunctivitis adalah durasi paparan UV.

  1. The Actions of Lyophilized Apple Peel on the Electrical Activity and Organization of the Ventricular Syncytium of the Hearts of Diabetic Rats

    Directory of Open Access Journals (Sweden)

    Elideth Martínez-Ladrón de Guevara

    2016-01-01

    Full Text Available This study was designed to examine the effects of lyophilized red delicious apple peel (RDP on the action potentials (APs and the input resistance-threshold current relationship. The experiments were performed on isolated papillary heart muscles from healthy male rats, healthy male rats treated with RDP, diabetic male rats, and diabetic male rats treated with RDP. The preparation was superfused with oxygenated Tyrode’s solution at 37°C. The stimulation and the recording of the APs, the input resistance, and the threshold current were made using conventional electrophysiological methods. The RDP presented no significant effect in normal rats. Equivalent doses in diabetic rats reduced the APD and ARP. The relationship between input resistance and threshold current established an inverse correlation. The results indicate the following: (1 The functional structure of the cardiac ventricular syncytium in healthy rats is heterogeneous, in terms of input resistance and threshold current. Diabetes further accentuates the heterogeneity. (2 As a consequence, conduction block occurs and increases the possibility of reentrant arrhythmias. (3 These modifications in the ventricular syncytium, coupled with the increase in the ARP, are the adequate substrate so that, with diabetes, the heart becomes more arrhythmogenic. (4 RDP decreases the APD, the ARP, and most syncytium irregularity caused by diabetes.

  2. Combined hydrogen and lithium beam emission spectroscopy observation system for Korea Superconducting Tokamak Advanced Research

    Energy Technology Data Exchange (ETDEWEB)

    Lampert, M. [Wigner RCP, Euratom Association-HAS, Budapest (Hungary); BME NTI, Budapest (Hungary); Anda, G.; Réfy, D.; Zoletnik, S. [Wigner RCP, Euratom Association-HAS, Budapest (Hungary); Czopf, A.; Erdei, G. [Department of Atomic Physics, BME IOP, Budapest (Hungary); Guszejnov, D.; Kovácsik, Á.; Pokol, G. I. [BME NTI, Budapest (Hungary); Nam, Y. U. [National Fusion Research Institute, Daejeon (Korea, Republic of)

    2015-07-15

    A novel beam emission spectroscopy observation system was designed, built, and installed onto the Korea Superconducting Tokamak Advanced Research tokamak. The system is designed in a way to be capable of measuring beam emission either from a heating deuterium or from a diagnostic lithium beam. The two beams have somewhat complementary capabilities: edge density profile and turbulence measurement with the lithium beam and two dimensional turbulence measurement with the heating beam. Two detectors can be used in parallel: a CMOS camera provides overview of the scene and lithium beam light intensity distribution at maximum few hundred Hz frame rate, while a 4 × 16 pixel avalanche photo-diode (APD) camera gives 500 kHz bandwidth data from a 4 cm × 16 cm region. The optics use direct imaging through lenses and mirrors from the observation window to the detectors, thus avoid the use of costly and inflexible fiber guides. Remotely controlled mechanisms allow adjustment of the APD camera’s measurement location on a shot-to-shot basis, while temperature stabilized filter holders provide selection of either the Doppler shifted deuterium alpha or lithium resonance line. The capabilities of the system are illustrated by measurements of basic plasma turbulence properties.

  3. Electrical measurements of silicon sensors for the upgrade of the CMS detector; Vermessung von Siliziumsensoren fuer das Upgrade des CMS-Detektors

    Energy Technology Data Exchange (ETDEWEB)

    Stegler, Martin

    2013-05-15

    Because of the upgrade in the LHC (2020-2022), in which the luminosity is increased to above 5.10{sup 34} cm{sup -2}s{sup -1}, in the CMS tracker a much higher radiation exposure than hitherto is to be expected. Therefore radiation-hardened sensors are required. For this reason in the framework of the Hamamatsu-Photonics-KK campaign among others Mpix sensors are studied. Furthermore they are tested concerning their material properties by characterizing befor and after the irradiation. Also the optimal geometry is searched for. This thesis studies two substrate types of the same thickness with two isolating mechanisms. Thereby also the influence of the geometry and different bias structures is regarded in order to draw conclusions on the radiation hardness.

  4. Vermessung von Siliziumsensoren für das Upgrade des CMS-Detektors

    CERN Document Server

    Stegler, Martin; Seibold, Götz

    Aufgrund des Upgrades am LHC (2020-2022), bei dem die Luminosität auf über 5 · 1034 cm − 2 s − 1 erhöht wird, ist am CMS-Tracker eine weit höhere Strahlenbelastung als bisher zu erwarten. Daher werden strahlungshärtere Sensoren benötigt. Aus diesem Grund werden im Rahmen der Hamamatsu-Photonics-KK-Kampagne unter anderem Mpix-Sensoren untersucht. Des Weiteren werden sie auf ihre Materialeigenschaften geprüft, indem sie vor und nach der Bestrahlung charakterisiert werden. Ausserdem wird die optimale Geometrie gesucht. Diese Arbeit untersucht zwei Substrattypen derselben Dicke mit zwei Isolationsmechanismen. Dabei wird auch der Einfluss der Geometrie und unterschiedlicher Biasstrukturen berücksichtigt, um Schlüsse auf die Strahlungshärte zu ziehen.

  5. Size of silicon strip sensor from 6 inch wafer (right) compared to that from a 4 inch wafer (left).

    CERN Multimedia

    Honma, Alan

    1999-01-01

    Silicon strip sensors made from 6 inch wafers will allow for much larger surface area coverage at a reduced cost per unit surface area. A prototype sensor of size 8cm x 11cm made by Hamamatsu from a 6 inch wafer is shown next to a traditional 6cm x 6cm sensor from a 4 inch wafer.

  6. LHCb: High Voltage system for the LHCb calorimeter detectors at CERN

    CERN Multimedia

    Konoplyannikov, A

    2006-01-01

    All calorimeters are equipped with Hamamatsu photo tubes as devices for light to signal conversion. Eight thousand R7899-20 tubes are used for the electromagnetic and hadronic calorimeters and two hundred 64 channels multi-anode R7600 -00-M64 for Scintillator-Pad/Preshower detectors. Similar photo-detectors are widely used in the Molecular Imaging applications.

  7. Differential diagnosis of Parkinsonism using dual phase F 18 FP CIT PET imaging

    International Nuclear Information System (INIS)

    Jin, So Young; Oh, Min Young; Ok, Seung Jun; Oh, Jung Su; Lee, Sang Ju; Chung, Sun Ju; Lee, Chong Sik; Kim, Jae Seung

    2012-01-01

    Dopamine transporter (DAT) imaging can demonstrate presynaptic dopaminergic neuronal loss in Parkinson's disease (PD). However, differentiating atypical parkinsonism (APD) from PD is often difficult. We investigated the usefulness of dual phase F 18 FP CIT positron emission tomography (PET) imaging in the differential diagnosis of parkinsonism. Ninety eight subjects [five normal, seven drug induced parkinsonism (DIP), five essential tremor (ET), 24 PD, 20 multiple system atrophy parkinson type (MSA-P), 13 multiple system atrophy cerebellar type (MSA-C), 13 progressive supranuclear palsy (PSP), and 11 dementia with Lewy bodies(DLB)] underwent F 18 FP CIT PET. PET images were acquired at 5 min (early phase) and 3 h (late phase) after F 18 FP CIT administration (185MBq). Regional uptake pattern of cerebral and cerebellar hemispheres was assessed on early phase images, using visual, quantitative, and statistical parametric mapping (SPM) analyses. Striatal DAT binding was normal in normal, ET, DIP, and MSA C groups, but abnormal in PD, MSA P PSP, and DLB groups. No difference was found in regional uptake on early phase images among normal DAT binding groups, except in the MSA C group. Abnormal DAT binding groups showed different regional uptake pattern on early phase images compared with PD in SPM analysis (FDR<0.05). When discriminating APD from PD, visual interpretation of the early phase image showed high diagnostic sensitivity and specificity (75.4% and 100%, respectively). Regarding the ability to distinguish specific APD, sensitivities were 81% for MSA P, 77% for MSA C, 23% for PSP, and 54.5% for DLB. Dual phase F 18 FP CIT PET imaging is useful in demonstrating striatal DAT loss in neurodegenerative parkinsonism, and also in differentiating APD, particularly MSA, from PD

  8. Serum concentrations of chemokines (CCL-5 and CXCL-12), chemokine receptors (CCR-5 and CXCR-4), and IL-6 in patients with posttraumatic stress disorder and avoidant personality disorder.

    Science.gov (United States)

    Ogłodek, Ewa A; Szota, Anna M; Moś, Danuta M; Araszkiewicz, Aleksander; Szromek, Adam R

    2015-12-01

    Posttraumatic stress disorder (PTSD) can be perceived as a psychoneuroimmunological disorder in which cytokines affecting the neurochemical and neuroendocrine functions of the body play an important role. Among cytokines, chemokines participating in activation of the inflammatory response are considered to be crucial. 220 men and women were enrolled in the study. 180 of them constituted the study group. The studied groups consisted of: 60 patients with a diagnosed avoidant personality disorders (APD), 60 patients with a diagnosed APD and with PTSD and of 60 patients with PTSD but without a APD. There were 30 women and 30 men in each group of 60 subjects. The control group consisted of 40 healthy individuals. The plasma levels of chemokines and their receptors (CCL-5, CXCR-5, CXCL-12 and CXCR-4), as well as IL-6, were assessed by ELISA. There was an increase in the CXCL-12 and CCL-5 levels in women and men with the PTSD versus the control group. Also, increased levels of IL-6 and the receptors CXCR-4, CCR-5 were observed in women and men with PTSD. The levels of CXCL-12 and CCL-5 chemokines, as well as CCR-5 and CXCR4 receptors were higher in women than in men. The results of this study indicate a need for assessment of the CCL-5 and CXCL-12 chemokine levels, as they are likely markers of PTSD. Measurement of the concentrations of chemokines, chemokine receptors and IL-6 in women and men with PTSD along with concomittant APD may be useful for early detection of mental disorders. Copyright © 2015 Institute of Pharmacology, Polish Academy of Sciences. Published by Elsevier Urban & Partner Sp. z o.o. All rights reserved.

  9. Evaluation of the cardiotoxicity of mitragynine and its analogues using human induced pluripotent stem cell-derived cardiomyocytes.

    Directory of Open Access Journals (Sweden)

    Jun Lu

    Full Text Available Mitragynine is a major bioactive compound of Kratom, which is derived from the leave extracts of Mitragyna speciosa Korth or Mitragyna speciosa (M. speciosa, a medicinal plant from South East Asia used legally in many countries as stimulant with opioid-like effects for the treatment of chronic pain and opioid-withdrawal symptoms. Fatal incidents with Mitragynine have been associated with cardiac arrest. In this study, we determined the cardiotoxicity of Mitragynine and other chemical constituents isolated using human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs.The rapid delayed rectifier potassium current (IKr, L-type Ca2+ current (ICa,L and action potential duration (APD were measured by whole cell patch-clamp. The expression of KCNH2 and cytotoxicity was determined by real-time PCR and Caspase activity measurements. After significant IKr suppression by Mitragynine (10 µM was confirmed in hERG-HEK cells, we systematically examined the effects of Mitragynine and other chemical constituents in hiPSC-CMs. Mitragynine, Paynantheine, Speciogynine and Speciociliatine, dosage-dependently (0.1∼100 µM suppressed IKr in hiPSC-CMs by 67%∼84% with IC50 ranged from 0.91 to 2.47 µM. Moreover, Mitragynine (10 µM significantly prolonged APD at 50 and 90% repolarization (APD50 and APD90 (439.0±11.6 vs. 585.2±45.5 ms and 536.0±22.6 vs. 705.9±46.1 ms, respectively and induced arrhythmia, without altering the L-type Ca2+ current. Neither the expression, and intracellular distribution of KCNH2/Kv11.1, nor the Caspase 3 activity were significantly affected by Mitragynine.Our study indicates that Mitragynine and its analogues may potentiate Torsade de Pointes through inhibition of IKr in human cardiomyocytes.

  10. Transverse comparisons between ultrasound and radionuclide parameters in children with presumed antenatally detected pelvi-ureteric junction obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Duong, Hong Phuoc; Janssen, Francoise; Hall, Michelle; Ismaili, Khalid [Universite Libre de Bruxelles (ULB), Department of Pediatric Nephrology, Hopital Universitaire des Enfants Reine Fabiola, Brussels (Belgium); Piepsz, Amy [Hopital Universitaire Saint-Pierre, Department of Radioisotopes, Ghent (Belgium); Khelif, Karim; Collier, Frank [Universite Libre de Bruxelles (ULB), Department of Pediatric Urology, Hopital Universitaire des Enfants Reine Fabiola, Brussel (Belgium); Man, Kathia de [University Hospital Ghent, Department of Nuclear Medicine, Ghent (Belgium); Damry, Nash [Universite Libre de Bruxelles (ULB), Department of Pediatric Radiology, Hopital Universitaire des Enfants Reine Fabiola, Brussel (Belgium)

    2015-05-01

    The main criteria used for deciding on surgery in children with presumed antenatally detected pelviureteric junction obstruction (PPUJO) are the level of hydronephrosis (ultrasonography), the level of differential renal function (DRF) and the quality of renal drainage after a furosemide challenge (renography), the importance of each factor being far from generally agreed. Can we predict, on the basis of ultrasound parameters, the patient in whom radionuclide renography can be avoided? We retrospectively analysed the medical charts of 81 consecutive children with presumed unilateral PPUJO detected antenatally. Ultrasound and renographic studies performed at the same time were compared. Anteroposterior pelvic diameter (APD) and calyceal size were both divided into three levels of dilatation. Parenchymal thickness was considered either normal or significantly decreased. Acquisition of renograms under furosemide stimulation provided quantification of DRF, quality of renal drainage and cortical transit. The percentages of patients with low DRF and poor drainage were significantly higher among those with major hydronephrosis, severe calyceal dilatation or parenchymal thinning. Moreover, impaired cortical transit, which is a major risk factor for functional decline, was seen more frequently among those with very severe calyceal dilatation. However, none of the structural parameters obtained by ultrasound examination was able to predict whether the level of renal function or the quality of drainage was normal or abnormal. Alternatively, an APD <30 mm, a calyceal dilatation of <10 mm and a normal parenchymal thickness were associated with a low probability of decreased renal function or poor renal drainage. In the management strategy of patients with prenatally detected PPUJO, nuclear medicine examinations may be postponed in those with an APD <30 mm, a calyceal dilatation of <10 mm and a normal parenchymal thickness. On the contrary, precise estimation of DRF and renal

  11. Simulation and mechanistic investigation of the arrhythmogenic role of the late sodium current in human heart failure.

    Directory of Open Access Journals (Sweden)

    Beatriz Trenor

    Full Text Available Heart failure constitutes a major public health problem worldwide. The electrophysiological remodeling of failing hearts sets the stage for malignant arrhythmias, in which the role of the late Na(+ current (I(NaL is relevant and is currently under investigation. In this study we examined the role of I(NaL in the electrophysiological phenotype of ventricular myocytes, and its proarrhythmic effects in the failing heart. A model for cellular heart failure was proposed using a modified version of Grandi et al. model for human ventricular action potential that incorporates the formulation of I(NaL. A sensitivity analysis of the model was performed and simulations of the pathological electrical activity of the cell were conducted. The proposed model for the human I(NaL and the electrophysiological remodeling of myocytes from failing hearts accurately reproduce experimental observations. The sensitivity analysis of the modulation of electrophysiological parameters of myocytes from failing hearts due to ion channels remodeling, revealed a role for I(NaL in the prolongation of action potential duration (APD, triangulation of the shape of the AP, and changes in Ca(2+ transient. A mechanistic investigation of intracellular Na(+ accumulation and APD shortening with increasing frequency of stimulation of failing myocytes revealed a role for the Na(+/K(+ pump, the Na(+/Ca(2+ exchanger and I(NaL. The results of the simulations also showed that in failing myocytes, the enhancement of I(NaL increased the reverse rate-dependent APD prolongation and the probability of initiating early afterdepolarizations. The electrophysiological remodeling of failing hearts and especially the enhancement of the I(NaL prolong APD and alter Ca(2+ transient facilitating the development of early afterdepolarizations. An enhanced I(NaL appears to be an important contributor to the electrophysiological phenotype and to the dysregulation of [Ca(2+](i homeostasis of failing myocytes.

  12. Electrophysiological Characteristics of Embryonic Stem Cell-Derived Cardiomyocytes are Cell Line-Dependent

    Directory of Open Access Journals (Sweden)

    Tobias Hannes

    2015-01-01

    Full Text Available Background: Modelling of cardiac development, physiology and pharmacology by differentiation of embryonic stem cells (ESCs requires comparability of cardiac differentiation between different ESC lines. To investigate whether the outcome of cardiac differentiation is consistent between different ESC lines, we compared electrophysiological properties of ESC-derived cardiomyocytes (ESC-CMs of different murine ESC lines. Methods: Two wild-type (D3 and R1 and two transgenic ESC lines (D3/aPIG44 and CGR8/AMPIGX-7 were differentiated under identical culture conditions. The transgenic cell lines expressed enhanced green fluorescent protein (eGFP and puromycin-N-acetyltransferase under control of the cardiac specific α-myosin heavy chain (αMHC promoter. Action potentials (APs were recorded using sharp electrodes and multielectrode arrays in beating clusters of ESC-CMs. Results: Spontaneous AP frequency and AP duration (APD as well as maximal upstroke velocity differed markedly between unpurified CMs of the four ESC lines. APD heterogeneity was negligible in D3/aPIG44, moderate in D3 and R1 and extensive in CGR8/AMPIGX-7. Interspike intervals calculated from long-term recordings showed a high degree of variability within and between recordings in CGR8/AMPIGX-7, but not in D3/aPIG44. Purification of the αMHC+ population by puromycin treatment posed only minor changes to APD in D3/aPIG44, but significantly shortened APD in CGR8/AMPIGX-7. Conclusion: Electrophysiological properties of ESC-CMs are strongly cell line-dependent and can be influenced by purification of cardiomyocytes by antibiotic selection. Thus, conclusions on cardiac development, physiology and pharmacology derived from single stem cell lines have to be interpreted carefully.

  13. Chiral recognition of pinacidil and its 3-pyridyl isomer by canine cardiac and smooth muscle: Antagonism by sulfonylureas

    International Nuclear Information System (INIS)

    Steinberg, M.I.; Wiest, S.A.; Zimmerman, K.M.; Ertel, P.J.; Bemis, K.G.; Robertson, D.W.

    1991-01-01

    Pinacidil, a potassium channel opener (PCO), relaxes vascular smooth muscle by increasing potassium ion membrane conductance, thereby causing membrane hyperpolarization. PCOs also act on cardiac muscle to decrease action potential duration (APD) selectively. To examine the enantiomeric selectivity of pinacidil, the stereoisomers of pinacidil (a 4-pyridylcyanoguanidine) and its 3-pyridyl isomer (LY222675) were synthesized and studied in canine Purkinje fibers and cephalic veins. The (-)-enantiomers of both pinacidil and LY222675 were more potent in relaxing phenylephrine-contracted cephalic veins and decreasing APD than were their corresponding (+)-enantiomers. The EC50 values for (-)-pinacidil and (-)-LY222675 in relaxing cephalic veins were 0.44 and 0.09 microM, respectively. In decreasing APD, the EC50 values were 3.2 microM for (-)-pinacidil and 0.43 microM for (-)-LY222675. The eudismic ratio was greater for the 3-pyridyl isomer than for pinacidil in both cardiac (71 vs. 22) and vascular (53 vs. 17) tissues. (-)-LY222675 and (-)-pinacidil (0.1-30 microM) also increased 86Rb efflux from cephalic veins to a greater extent than did their respective optical antipodes. The antidiabetic sulfonylurea, glyburide (1-30 microM), shifted the vascular concentration-response curve of (-)-pinacidil to the right by a similar extent at each inhibitor concentration. Glipizide also antagonized the response to (-)-pinacidil, but was about 1/10 as potent with a maximal shift occurring at 10 and 30 microM. Glyburide antagonized the vascular relaxant effects of 0.3 microM (-)-LY222675 (EC50, 2.3 microM) and reversed the decrease in APD caused by 3 microM (-)-LY222675 (EC50, 1.9 microM). Nitroprusside did not alter 86Rb efflux, and vascular relaxation induced by sodium nitroprusside was unaffected by sulfonylureas

  14. SWIR HgCdTe avalanche photiode focal plane array performances evaluation

    Science.gov (United States)

    de Borniol, E.; Rothman, J.; Salveti, F.; Feautrier, P.

    2017-11-01

    One of the main challenges of modern astronomical instruments like adaptive optics (AO) systems or fringe trackers is to deal with the very low photons flux detection scenarios. The typical timescale of atmospheric turbulences being in the range of some tens of milliseconds, infrared wavefront sensors for AO systems needs frame rates higher than 1 KHz leading to integration times lower than 1 ms. This integration time associated with a low irradiance results in a few number of integrated photons per frame per pixel. To preserve the information coming from this weak signal, the focal plane array (FPA) has to present a low read out noise, a high quantum efficiency and a low dark current. Up to now, the output noise of high speed near infrared sensors is limited by the silicon read out circuit noise. The use of HgCdTe avalanche photodiodes with high gain at moderate reverse bias and low excess noise seems then a logical way to reduce the impact of the read noise on images signal to noise ratio. These low irradiance passive imaging applications with integration times in the millisecond range needs low photodiode dark current and low background current. These requirements lead to the choice of the photodiode cut off wavelength. The short wave infrared (SWIR) around 3 μm is a good compromise between the gain that can be obtain for a given APD bias and the background and dark current. The CEA LETI HgCdTe APD technology, and a fine analysis of the gain curve characteristic are presented in [1] and won't be detailed here. The response time of the APD is also a key factor for a high frame rate FPA. This parameter has been evaluated in [2] and the results shows cut off frequencies in the GHz range. In this communication we report the performances of a SWIR APD FPA designed and fabricated by CEA LETI and SOFRADIR for astrophysical applications. This development was made in the frame of RAPID, a 4 years R&D project funded by the French FUI (Fond Unique Interministériel). This

  15. TH-C-19A-10: Systematic Evaluation of Photodetectors Performances for Plastic Scintillation Dosimetry

    International Nuclear Information System (INIS)

    Boivin, J; Beaulieu, L; Beddar, S; Guillemette, M

    2014-01-01

    Purpose: To assess and compare the performance of different photodetectors likely to be used in a plastic scintillation detector (PSD). Methods: The PSD consists of a 1 mm diameter, 10 mm long plastic scintillation fiber (BCF-60) which is optically coupled to a clear 10 m long optical fiber of the same diameter. A light-tight plastic sheath covers both fibers and the scintillator end is sealed. The clear fiber end is connected to one of the following six studied photodetectors: two polychromatic cameras (one with an optical lens and one with a fiber optic taper replacing the lens); a monochromatic camera with the same optical lens; a PIN photodiode; an avalanche photodiode (APD); and a photomultiplier tube (PMT). Each PSD is exposed to both low energy beams (120, 180, and 220 kVp) from an orthovoltage unit, and high energy beams (6 MV and 23 MV) from a linear accelerator. Various dose rates are explored to identify the photodetectors operating ranges and accuracy. Results: For all photodetectors, the relative uncertainty remains under 5 % for dose rates over 3 mGy/s. The taper camera collects four times more signal than the optical lens camera, although its standard deviation is higher since it could not be cooled. The PIN, APD and PMT have higher sensitivity, suitable for low dose rate and out-of-field dose monitoring. PMT's relative uncertainty remains under 1 % at the lowest dose rate achievable (50 μGy/s), suggesting optimal use for live dosimetry. Conclusion: A set of 6 photodetectors have been studied over a broad dose rate range at various energies. For dose rate above 3 mGy/s, the PIN diode is the most effective photodetector in term of performance/cost ratio. For lower dose rate, such as those seen in interventional radiology, PMTs are the optimal choice. FQRNT Doctoral Research Scholarship

  16. Studies of avalanche photodiodes for scintillating fibre tracking readout

    International Nuclear Information System (INIS)

    Fenker, H.; Thomas, J.

    1993-01-01

    Avalanche Photodiodes (APDs) operating in ''Geiger Mode'' have been studied in a fibre tracking readout environment. A fast recharge circuit has been developed for high rate data taking, and results obtained from a model fibre tracker in the test beam at Brookhaven National Laboratory are presented. A high rate calibrated light source has been developed using a commercially available laser diode and has been used to measure the efficiency of the devices. The transmission of the light from a 1mm fibre onto a 0.5mm diameter APD surface has been identified as the main problem in the use of these particular devices for scintillating fibre tracking in the Superconducting Supercollider environment. Solutions to this problem are proposed

  17. Study of SiPM as a potential photodetector for scintillator readout

    International Nuclear Information System (INIS)

    Herbert, D.J.; D'Ascenzo, N.; Belcari, N.; Del Guerra, A.; Morsani, F.; Saveliev, V.

    2006-01-01

    The Silicon PhotoMultiplier (SiPM) APD represents an interesting advance in photodetection and could soon be a rival to traditional PMTs in many applications. The SiPM is effectively a densely packed 2D array of Geiger-mode APD microcells, each having individual resistive quenching and multiplexed outputs. In this way the SiPM acts as a linear, high-gain photodetector for moderate photon flux (N photon cells ). The Metal-Resistor-Silicon (MRS) structure SiPM, produced by CPTA Russia, has been characterised and tested for scintillator light detection in medical applications such as PET. We present a summary of measurements of the device's primary operating characteristics and results of the application to scintillator readout

  18. SNR characteristics of 850-nm OEIC receiver with a silicon avalanche photodetector.

    Science.gov (United States)

    Youn, Jin-Sung; Lee, Myung-Jae; Park, Kang-Yeob; Rücker, Holger; Choi, Woo-Young

    2014-01-13

    We investigate signal-to-noise ratio (SNR) characteristics of an 850-nm optoelectronic integrated circuit (OEIC) receiver fabricated with standard 0.25-µm SiGe bipolar complementary metal-oxide-semiconductor (BiCMOS) technology. The OEIC receiver is composed of a Si avalanche photodetector (APD) and BiCMOS analog circuits including a transimpedance amplifier with DC-balanced buffer, a tunable equalizer, a limiting amplifier, and an output buffer with 50-Ω loads. We measure APD SNR characteristics dependence on the reverse bias voltage as well as BiCMOS circuit noise characteristics. From these, we determine the SNR characteristics of the entire OEIC receiver, and finally, the results are verified with bit-error rate measurement.

  19. Self-esteem and other-esteem in college students with borderline and avoidant personality disorder features: An experimental vignette study.

    Science.gov (United States)

    Bowles, David P; Armitage, Chris J; Drabble, Jennifer; Meyer, Björn

    2013-11-01

    An experimental study investigated self-esteem and other-esteem responses to either fully supportive or less supportive interpersonal feedback in college students with avoidant and borderline personality disorder features (APD and BPD respectively). Disturbances in self-esteem and in evaluations of others are central to definitions of both APD and BPD, but the extent to which such interpersonal appraisals are responsive to contextual features, such as evaluative feedback from others, is not yet clear. In theory, we would expect that individuals with pronounced PD features would show more inflexible and more negative self-evaluations and others- evaluations than those without PD features. In this study with 169 undergraduates, APD but not BPD features were associated with other-contingent state self-esteem and other-esteem. A significant interaction indicated that highly avoidant respondents felt particularly negatively about themselves and their close others in situations that conveyed subtle criticism but not in situations signalling unequivocal support. This suggests that their self-esteem and other-esteem, rather than being rigidly negative, are instead highly contingent upon interpersonal feedback. Such context contingency has implications for the trait-like description of diagnostic characteristics within current taxonomies and is in line with contemporary dynamic models of personality structure and process. Copyright © 2013 John Wiley & Sons, Ltd.

  20. Artificial Pancreas Device Systems for the Closed-Loop Control of Type 1 Diabetes

    Science.gov (United States)

    Trevitt, Sara; Simpson, Sue; Wood, Annette

    2015-01-01

    Background: Closed-loop artificial pancreas device (APD) systems are externally worn medical devices that are being developed to enable people with type 1 diabetes to regulate their blood glucose levels in a more automated way. The innovative concept of this emerging technology is that hands-free, continuous, glycemic control can be achieved by using digital communication technology and advanced computer algorithms. Methods: A horizon scanning review of this field was conducted using online sources of intelligence to identify systems in development. The systems were classified into subtypes according to their level of automation, the hormonal and glycemic control approaches used, and their research setting. Results: Eighteen closed-loop APD systems were identified. All were being tested in clinical trials prior to potential commercialization. Six were being studied in the home setting, 5 in outpatient settings, and 7 in inpatient settings. It is estimated that 2 systems may become commercially available in the EU by the end of 2016, 1 during 2017, and 2 more in 2018. Conclusions: There are around 18 closed-loop APD systems progressing through early stages of clinical development. Only a few of these are currently in phase 3 trials and in settings that replicate real life. PMID:26589628