WorldWideScience

Sample records for ha iso sokudo

  1. Inversion of Love wave phase velocity using smoothness-constrained least-squares technique; Heikatsuka seiyakutsuki saisho jijoho ni yoru love ha iso sokudo no inversion

    Energy Technology Data Exchange (ETDEWEB)

    Kawamura, S [Nippon Geophysical Prospecting Co. Ltd., Tokyo (Japan)

    1996-10-01

    Smoothness-constrained least-squares technique with ABIC minimization was applied to the inversion of phase velocity of surface waves during geophysical exploration, to confirm its usefulness. Since this study aimed mainly at the applicability of the technique, Love wave was used which is easier to treat theoretically than Rayleigh wave. Stable successive approximation solutions could be obtained by the repeated improvement of velocity model of S-wave, and an objective model with high reliability could be determined. While, for the inversion with simple minimization of the residuals squares sum, stable solutions could be obtained by the repeated improvement, but the judgment of convergence was very hard due to the smoothness-constraint, which might make the obtained model in a state of over-fitting. In this study, Love wave was used to examine the applicability of the smoothness-constrained least-squares technique with ABIC minimization. Applicability of this to Rayleigh wave will be investigated. 8 refs.

  2. On-site processing systems for determination of the phase velocity of Rayleigh waves in microtremors using the spatial autocorrelation method; Kukan jiko sokanho wo mochiita bidochu no Rayleigh ha iso sokudo no genba kettei system

    Energy Technology Data Exchange (ETDEWEB)

    Matsuoka, T; Umezawa, N [Saitama Institute of Environmental Pollution, Saitama (Japan)

    1996-05-01

    To render the spatial autocorrelation (SAC) method easier to use, a system has been constructed that can be used with ease on the site for the calculation of phase velocities. This system can perform two observation methods of the same frequency characteristics, that is, the simultaneous multi-point observation and one-point independent observation. The pickup is a velocity type seismograph of a natural period of 1 second that has been so electrically adjusted as to work on an apparent natural period of 7 seconds. Among the frequency characteristics, those related to phase are regarded as important because the SAC method is based on the measurement of coherence between two points. The analysis software runs on a waveform processing software DADiSP/WIN designed for personal computers. To know the operability of this system on the site and to accumulate records using the SAC method, observations were made at the depth of 100-500m at 6 locations in Saitama Prefecture where the underground structure was known thanks to prior PS logging. As the result, a dispersion curve was obtained by use of an array of appropriate dimensions at every location agreeing with the underground structure. 9 refs., 10 figs.

  3. Experiment for estimating phase velocity and power fraction of Love wave from three component microtremor array observation in Morioka area; Moriokashiiki deno bido no sanseibun array kansoku ni yoru love ha no iso sokudo oyobi power hi suitei no kokoromi

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, H; Yakuwa, A; Saito, T [Iwate University, Iwate (Japan). Faculty of Engineering

    1997-10-22

    Three component microtremor array observations were carried out in two locations in the city of Morioka for an attempt of estimating phase velocity and power fraction of Love wave by applying the expanded three component spatial self-correlation method. The microtremors were observed by using a seismograph with a natural period of one second. The arrays were so arranged as to form an equilateral triangle consisted of seven points. The maximum radii were 100 m, 50 m, 25 m and 12.5 m for vertical movements, and 100 m and 30 m for horizontal movements at the Iwate University, and 80 m, 40 m, 20 m and 10 m for vertical movements and 90 m for horizontal movements at the Morioka Technical Highschool. The analysis has used three sections, each with relatively steady state of about 40 seconds as selected from records of observations for about 30 minutes. The result of the discussions revealed that it is possible to derive phase velocity of not only Rayleigh waves but also Love waves by applying the expanded spatial self-correlation method to the observation record. Thus, estimation of underground structures with higher accuracy has become possible by using simultaneously the Rayleigh waves and Love waves. 3 refs., 11 figs., 2 tabs.

  4. ISO 9000

    International Nuclear Information System (INIS)

    Graham, J.F.

    1992-01-01

    The European Community has adopted the Single European Act. The act states that in order to do business in Europe after 1992, a supplied is expected to be ISO 9000 registered. This paper reports on ISO 9000, which is a systematic approach to implementing a quality system. It is not in the category of technical or product standards, but a standard relating to management of quality in that sector of a company seeking registration. If a company is already systematically practicing quality improvement, these efforts will be applicable to the ISO 9000 certification process. A company will need to refine and update procedures and develop a quality manual. An internal auditing and a corrective action system will also have to be established. The latter addresses audit results, customer complaints, quality system problems, and internal quality improvement suggestions

  5. ISO 14001

    DEFF Research Database (Denmark)

    Jørgensen, Tine Herreborg

    2004-01-01

    The aim of this paper is to discuss a number of issues related to ISO 14001, the international standard for environmental management systems (EMS). The standard is a process standard that leaves room for interpretation at company level as well as among lead auditors from certifying bodies...

  6. ISO27001 / ISO27002 a pocket guide

    CERN Document Server

    Calder, Alan

    2013-01-01

    Information is one of your organisation's most important resources. Keeping it secure is therefore vital to your business. This handy pocket guide is an essential overview of two key information security standards that cover the formal requirements (ISO27001:2013) for creating an Information Security Management System (ISMS), and the best-practice recommendations (ISO27002:2013) for those responsible for initiating, implementing or maintaining it.

  7. HA-Coated Implant

    DEFF Research Database (Denmark)

    Daugaard, Henrik; Søballe, Kjeld; Bechtold, Joan E

    2014-01-01

    of improving the fixation of implants. Of these, hydroxyapatite (HA) is the most widely used and most extensively investigated. HA is highly osseoconductive, and the positive effect is well documented in both basic and long-term clinical research [1–6]. This chapter describes experimental and clinical studies...

  8. ISO radiation sterilization standards

    International Nuclear Information System (INIS)

    Lambert, Byron J.; Hansen, Joyce M.

    1998-01-01

    This presentation provides an overview of the current status of the ISO radiation sterilization standards. The ISO standards are voluntary standards which detail both the validation and routine control of the sterilization process. ISO 11137 was approved in 1994 and published in 1995. When reviewing the standard you will note that less than 20% of the standard is devoted to requirements and the remainder is guidance on how to comply with the requirements. Future standards developments in radiation sterilization are being focused on providing additional guidance. The guidance that is currently provided in informative annexes of ISO 11137 includes: device/packaging materials, dose setting methods, and dosimeters and dose measurement, currently, there are four Technical Reports being developed to provide additional guidance: 1. AAMI Draft TIR, 'Radiation Sterilization Material Qualification' 2. ISO TR 13409-1996, 'Sterilization of health care products - Radiation sterilization - Substantiation of 25 kGy as a sterilization dose for small or infrequent production batches' 3. ISO Draft TR, 'Sterilization of health care products - Radiation sterilization Selection of a sterilization dose for a single production batch' 4. ISO Draft TR, 'Sterilization of health care products - Radiation sterilization-Product Families, Plans for Sampling and Frequency of Dose Audits'

  9. ISO radiation protection standards

    International Nuclear Information System (INIS)

    Becker, K.; West, N.

    1981-01-01

    After a brief description of the International Organization for Standardization (ISO) and its Technical Committee (TC) 85 ''Nuclear Energy'', the work of its Sub-Committee (SC) 2 ''Radiation Protection'' is described in some detail. Several international standards on subjects closely related to radiation protection have already been published, for example ISO-361 (Basic radiation protection symbol), ISO-1757 (Photographic dosimeters), ISO-1758 and 1759 (Direct and indirect-reading pocket exposure meters), ISO-2889 (Sampling of airborne radioactive materials), ISO-4037 (X and gamma reference radiations for calibration) and ISO-4071 (Testing of exposure meters and dosimeters). TC 85/SC 2 has currently eight active Working Groups (WG) dealing with 14 standards projects, mostly in advanced stages, in such fields as neutron and beta reference radiations, and X and gamma radiations of high and low dose-rates and high energies for calibration purposes, reference radiations for surface contamination apparatus, ejection systems for gamma radiography apparatus, industrial and laboratory irradiators, lead shielding units, protective clothing, thermoluminescence dosemeters, radioelement gauges, and surface contamination and decontamination. (author)

  10. Mishima jo ha kyu

    Directory of Open Access Journals (Sweden)

    Matteo Casari

    2012-01-01

    Full Text Available Abstract – IT La grandezza artistica di Mishima si è espressa attraverso una eterogenea gamma di linguaggi tra i quali il teatro – nella drammaturgia ma anche nella saggistica, regia, recitazione e direzione di compagnia – ha avuto un ruolo di primo piano. Al pari di un uomo di scena Mishima inaugura, a partire dagli anni ’50, un processo di attenzione al proprio corpo come possibile, anzi necessario, veicolo di estrinsecazione etico-estetica tanto da poter istituire l’equazione corpo-teatro quale snodo profondo del suo processo creativo. Il corpo sognato e ottenuto da Mishima attraverso l’addestramento nel kendo, in altre arti marziali e nel body building si conformava ad un ideale estetico di matrice greco-classica assai lontano dal corpo teatrale nipponico. Il corpo come luogo di elaborazione e strumento di espressione autentica da realizzare con impegno, però, lo legano profondamente alle esperienze nascenti – tra gli anni ’50 e ’60 – delle avanguardie teatrali giapponesi. La metafora teatrale è spesso usata nella lettura critica del Mishima uomo e artista con accezione deteriore: un personaggio che dà spettacolo di sé con ripetute provocazioni tra le quali il suicidio del 25 novembre 1970 non sarebbe che l’esempio ultimo e più estremo. La costruzione di sé come personaggio, invece, sembrerebbe corrispondere ad una ben più profonda e meditata necessità di comporre la propria vita in una sapiente messa in scena di classica perfezione: i principi della scansione ritmico formale del jo ha kyu, pilastro teorico del teatro no codificato da Zeami tra XIV e XV secolo, offrono un valido modello di riferimento. Abstract – EN Mishima’s artistic greatness has been expressed through a diverse range of languages among wich theater – in dramaturgy as well as in written essays, as a director, performer and in company direction – played a central role. As a true front-man, Mishima – starting from the 50’s

  11. Control: the effects of ISO

    NARCIS (Netherlands)

    Laura Ilzarbe; PhD Everard van Kemenade; Maria-Jezus Alvarez

    2007-01-01

    De effecten van ISO-certificering zoals gerapporteerd in wetenschappelijk onderzoek. Met speciale aandacht voor de resultaten in het onderwijs. ISO 9000:2000 doet het nadrukkelijk beter dan haar vorige versies.

  12. Accreditation - ISO/IEC 17025

    Science.gov (United States)

    Kaus, Rüdiger

    This chapter gives the background on the accreditation of testing and calibration laboratories according to ISO/IEC 17025 and sets out the requirements of this international standard. ISO 15189 describes similar requirements especially tailored for medical laboratories. Because of these similarities ISO 15189 is not separately mentioned throughout this lecture.

  13. ISO CD 14492

    DEFF Research Database (Denmark)

    Martins, Bo; Kossentini, F.; Arps, R.

    1998-01-01

    This Recommendation | International Standard, informally called JBIG2, defines a coding method for bilevel images, that is, images consisting of a single rectangular bit plane, with each pixel taking on one of just two possible colors. Itis being drafted by the Joint Bi-level Image Experts Group ...... (JBIG), a "Collaborative team" that reports both to ISO/IEC JTC1/SC29/WG1 and to ITU-T/SG8....

  14. USGIN ISO metadata profile

    Science.gov (United States)

    Richard, S. M.

    2011-12-01

    The USGIN project has drafted and is using a specification for use of ISO 19115/19/39 metadata, recommendations for simple metadata content, and a proposal for a URI scheme to identify resources using resolvable http URI's(see http://lab.usgin.org/usgin-profiles). The principal target use case is a catalog in which resources can be registered and described by data providers for discovery by users. We are currently using the ESRI Geoportal (Open Source), with configuration files for the USGIN profile. The metadata offered by the catalog must provide sufficient content to guide search engines to locate requested resources, to describe the resource content, provenance, and quality so users can determine if the resource will serve for intended usage, and finally to enable human users and sofware clients to obtain or access the resource. In order to achieve an operational federated catalog system, provisions in the ISO specification must be restricted and usage clarified to reduce the heterogeneity of 'standard' metadata and service implementations such that a single client can search against different catalogs, and the metadata returned by catalogs can be parsed reliably to locate required information. Usage of the complex ISO 19139 XML schema allows for a great deal of structured metadata content, but the heterogenity in approaches to content encoding has hampered development of sophisticated client software that can take advantage of the rich metadata; the lack of such clients in turn reduces motivation for metadata producers to produce content-rich metadata. If the only significant use of the detailed, structured metadata is to format into text for people to read, then the detailed information could be put in free text elements and be just as useful. In order for complex metadata encoding and content to be useful, there must be clear and unambiguous conventions on the encoding that are utilized by the community that wishes to take advantage of advanced metadata

  15. ISO 9000 Quality Management System

    Science.gov (United States)

    Hadjicostas, Evsevios

    The ISO 9000 series describes a quality management system applicable to any organization. In this chapter we present the requirements of the standard in a way that is as close as possible to the needs of analytical laboratories. The sequence of the requirements follows that in the ISO 9001:2008 standard. In addition, the guidelines for performance improvement set out in the ISO 9004 are reviewed. Both standards should be used as a reference as well as the basis for further elaboration.

  16. ISO 14000 : environmental management systems

    International Nuclear Information System (INIS)

    Boutin, C.; Emard, C.; Lalonde, G.; Levesque, A.; Robitaille, R.; Rollin, A.L.; Thibeault, I.

    1996-01-01

    This book is addressed to the managers, professionals, and government agents which wish to know the philosophy of the step as well as the stages to be followed for the establishment of a system of environmental management in conformity with the standards of the series ISO 14000. This work locates ISO 14000 in the historical context of its development by describing the bonds with other standards in place of which those of the series ISO 9000. This book answers questions that arise regarding a companies step toward accreditation to ISO 14000

  17. Probable maximum flood on the Ha Ha River

    International Nuclear Information System (INIS)

    Damov, D.; Masse, B.

    1997-01-01

    Results of a probable maximum flood (PMF) study conducted for various locations along the Ha Ha river, a tributary of the Saguenay River, were discussed. The study was undertaken for use in the design and construction of new hydraulic structures for water supply for a pulp and paper facility, following the Saguenay Flood in July 1996. Many different flood scenarios were considered, including combinations of snow-melt with rainfall. Using computer simulations, it was shown that the largest flood flows were generated by summer-fall PMF. 5 refs., 12 figs

  18. The international ISOE programme. ISOE European technical centre activities

    International Nuclear Information System (INIS)

    Ascenzo, L. d'; Crouail, P.; Levy, F.; Livolsi, P.; Schieber, C.; Lefaure, C.

    1996-01-01

    The CEPN has been involved from the beginning in the NEA Information System on Occupational Exposure (ISOE). As ISOE European Technical Centre, the CEPN is responsible for the collection and distribution of European data to the various ISOE partners, the collection of data from the other regional technical centres, and the custodianship of the full ISOE data base. This full data base is updated annually and distributed to all the European participating utilities and to other Regional Technical Centres. The European data are also sent to the European Commission (EC) as a contribution to their own occupational exposure data base. In addition to these activities, the CEPN has developed two computer programmes under Windows to facilitate the management of ISOE data bases. The first software, called ASPIC, allows participating utilities to electronically complete NEA1 and NEA3 questionnaires, as well as to consult the NEA3 data base using key words search routine. This software is available in six different languages. The second programme is a relational data base for the performance of statistical analyses using data from NEA1. The CEPN also contributes significantly to the efficient flow of information through the ISOE Network. This includes participation in the preparation and distribution of the ISOE Annual Report (which presents and analyses NEAI data), ISOE Information Sheets (providing short synthesis using NEA1 and NEA3 data), and Technical Reports. Participating Authorities and Utilities have each made information requests to the CEPN concerning dosimetric data, radiation protection experiences, policies and practices. Some examples of these requests, and of the types of data provided, will be presented. (author)

  19. NDT technical assessment for ISO 17025 and ISO 17020 certification

    International Nuclear Information System (INIS)

    Mohamad Pauzi Ismail

    2011-01-01

    ISO 17025 is an international standard that states the requirement criteria for testing and calibration laboratory, while ISO 17020 is for inspection body. Standard Malaysia is the accreditation body for both standards. The author involved in the technical assessment for both standards both in Nuclear Malaysia and outside. The experience in performing NDT assessment activity is explained and discussed. The comparison between both standards is also discussed. (author)

  20. ISO 9001 quality management systems

    CERN Document Server

    Natarajan, Dhanasekharan

    2017-01-01

    This book explains the requirements of ISO 9001 for establishing quality management system (QMS) for an organization. The requirements are illustrated with examples from industries for understanding the requirements and preparing the documents of QMS with high clarity. Methods of integrating ISO 9001 requirements with enterprise resource planning (ERP) software are presented. The software integrated approach enables process owners to focus on their core tasks of achieving the planned outputs of processes and the software generates quality records automatically.

  1. Integrated management system: The integration of ISO 9001, ISO 14001, OHSAS 18001 and ISO 31000

    Science.gov (United States)

    Muzaimi, Hafizzudin; Chew, Boon Cheong; Hamid, Syaiful Rizal

    2017-03-01

    The implementation of integrated management system (IMS) for better quality management has become a preference for many organizations. This can be seen as many organizations used the combination of quality ISO 9001, an environment ISO 14001 and occupational health and safety management system OHSAS 18001 as a core for the IMS that largely implemented. Besides, the linked between quality management with risk management system need to be identified as the management system that enhance the effectiveness of IMS. Therefore, the risk management system ISO 31000 also presented as a part of integration. In nowadays competitive environment, the increasing pressure and needs from customer or stakeholders make it compulsory for the organization to propose the new system and standards. This paper presents and discusses about the benefit of integration, the management system components that can be converged and the implementation approach. A series of interview was conducted through in-depth interviews with 8 experts in this field, while data collected were analyzed qualitatively. The results consist of 16 factors of IMS implementation that have been identified and the use of PDCA approach for an effective implementation of IMS. As a conclusion, the paper proposes the integration of four management systems (ISO 9001, ISO 14001, OHSAS 18001 and ISO 31000) and on how the IMS can be used to structure the process of management for quality management towards sustainability practices in the organization.

  2. Tinjauan Kritis Terhadap Implementasi Iso 9000

    OpenAIRE

    Purnama, Nursya’bani

    2005-01-01

    ISO 9000 telah diterima secara luas sebagai acuan sistem manajemen kualitas dan penjaminan kualitas. Perusahaan-Perusahaan yang memperoleh sertifikasi ISO dari tahun ke ke tahun mengalami pertumbu¬han yang pesat. Dengan implementasi dan memperoleh sertifikasi ISO 9000, banyak Perusahaan di dunia mem¬peroleh peningkatan kinerja. Meskipun demikian, implementasi ISO 9000 juga dihadapkan pada sejumlah ham¬batan. Implementasi ISO 9000 seringkali dikaitkan dengan Total Quality Management (TQM). Ban...

  3. [ISO 15189 medical laboratory accreditation].

    Science.gov (United States)

    Aoyagi, Tsutomu

    2004-10-01

    This International Standard, based upon ISO/IEC 17025 and ISO 9001, provides requirements for competence and quality that are particular to medical laboratories. While this International Standard is intended for use throughout the currently recognized disciplines of medical laboratory services, those working in other services and disciplines will also find it useful and appropriate. In addition, bodies engaged in the recognition of the competence of medical laboratories will be able to use this International Standard as the basis for their activities. The Japan Accreditation Board for Conformity Assessment (AB) and the Japanese Committee for Clinical Laboratory Standards (CCLS) are jointly developing the program of accreditation of medical laboratories. ISO 15189 requirements consist of two parts, one is management requirements and the other is technical requirements. The former includes the requirements of all parts of ISO 9001, moreover it includes the requirement of conformity assessment body, for example, impartiality and independence from any other party. The latter includes the requirements of laboratory competence (e.g. personnel, facility, instrument, and examination methods), moreover it requires that laboratories shall participate proficiency testing(s) and laboratories' examination results shall have traceability of measurements and implement uncertainty of measurement. Implementation of ISO 15189 will result in a significant improvement in medical laboratories management system and their technical competence. The accreditation of medical laboratory will improve medical laboratory service and be useful for patients.

  4. Environmental Management System ISO 14001

    CERN Document Server

    Haider, Syed

    2010-01-01

    This is a must-have tool for any company in the process of adopting and incorporating the ISO 14001:2004 requirements, this book and accompanying CD-ROM provides the latest updates and amendments and translates the ISO language into actionable strategy. Offering administrative solutions to managers of all sorts, it includes practical examples of policies with objectives, targets, and action plans applicable to any process related industry or an ordinary organization. With template formats and hands-on flow charts to describe step-by-step system development, documentation, and implementation ph

  5. Food service compliance with ISO 14001 and ISO 22000

    Directory of Open Access Journals (Sweden)

    Laura Lyra Santos

    2012-06-01

    Full Text Available OBJECTIVE: The objective of this study was to assess food service environmental and food safety management systems according to two checklists based on ABNT ISO 22000 and 14001. METHODS: This exploratory and descriptive study investigated a-la-carte food services of the Federal District, Brazil. Two checklists were developed to investigate ISO 14001 and 22000 compliance. A total of 37 food services were selected from the list of the Brazilian Association of Bars and Restaurants by simple random sampling. Checklist results were analyzed according to ANVISA resolution nº 275/2002. RESULTS: Only five food services employed dietitians to supervise meal production. These establishments achieved the highest ISO compliance. However, no establishment had more than 50% ISO 14001 or 22000 compliance. Restaurants showed little concern for the environment and disobeyed waste disposal laws by not separating recyclables from non-recyclables. CONCLUSION: The study food services do not have safe meal production systems, evidenced by non-conformity with the reference standards. Additionally, they do not attempt to reduce the environmental impact of their wastes. Food services supervised by dietitians are better prepared to produce safe foods.

  6. Information security risk management for ISO27001/ISO27002

    CERN Document Server

    Calder, A; Watkins, S

    2010-01-01

    Drawing on international best practice, including ISO/IEC 27005, NIST SP800-30 and BS7799-3, the book explains in practical detail how to carry out an information security risk assessment. It covers key topics, such as risk scales, threats and vulnerabilities, selection of controls, and roles and responsibilities, and includes advice on choosing risk assessment software.

  7. Age, colors and ISO standards

    NARCIS (Netherlands)

    Nes, van F.L.; Eschbach, R; Marcu, G.G.; Tominaga, S.; Rizzi, A.

    2010-01-01

    Age influences all bodily functions, also vision. Therefore, the effects of age on vision should be mirrored in ergonomic requirements laid down in display standards such as ISO 9241-300/307, 'Electronic visual display requirements'. However, this is only true to a limited extent - just as is the

  8. ISO 14001: time for improvements?

    DEFF Research Database (Denmark)

    Jørgensen, Tine Herreborg

    2007-01-01

    The aim of this paper is to discuss a number of issues related to ISO 14001:2004, the international standard for Environmental Management Systems (EMS) with the purpose of improving the next edition in order to recognise and reflect new recognitions in approaches to pollution prevention. A case...

  9. Convenient method for estimating underground s-wave velocity structure utilizing horizontal and vertical components microtremor spectral ratio; Bido no suiheido/jogedo supekutoru hi wo riyoshita kan`i chika s ha sokudo kozo suiteiho

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, H; Yoshioka, M; Saito, T [Iwate University, Iwate (Japan). Faculty of Engineering

    1996-05-01

    Studies were conducted about the method of estimating the underground S-wave velocity structure by inversion making use of the horizontal/vertical motion spectral ratio of microtremors. For this purpose, a dynamo-electric velocity type seismograph was used, capable of processing the east-west, north-south, and vertical components integratedly. For the purpose of sampling the Rayleigh wave spectral ratio, one out of all the azimuths was chosen, whose horizontal motion had a high Fourier frequency component coherency with the vertical motions. For the estimation of the underground S-wave velocity structure, parameters (P-wave velocity, S-wave velocity, density, and layer thickness) were determined from the minimum residual sum of squares involving the observed microtremor spectral ratio and the theoretical value calculated by use of a model structure. The known boring data was utilized for the study of the S-wave velocity in the top layer, and it was determined using an S-wave velocity estimation formula for the Morioka area constructed using the N-value, depth, and geological classification. It was found that the optimum S-wave velocity structure even below the top layer well reflects the S-wave velocity obtained by the estimation formula. 5 refs., 6 figs.

  10. Non-contact evaluation of mechanical properties of electroplated wear resistant Ni-P layer from the velocity dispersion of laser SAW; Laser reiki Rayleigh ha no sokudo bunsan wo mochiita taimamo Ni-P mekkiso tokusei no hisesshoku hyoka

    Energy Technology Data Exchange (ETDEWEB)

    Morikawa, Y.; Cho, H.; Takemoto, M. [Aoyama Gakuin University, Tokyo (Japan). Faculty of Science and Engineering; Nakayama, T. [Kobe Steel Ltd., Kobe (Japan)

    1996-11-01

    We developed a new laser surface acoustic wave (SAW) system and applied this to estimate the mechanical properties of the wear-resistant Ni-P layer electroplated on a stainless steel. The velocity dispersions of Rayleigh wave of the as -plated and heat-treated Ni-P layer were obtained by the one point time domain signal processing. The Ni-P layers with excellent wear resistance produced by the heated treatment higher than 725K were found to show higher Rayleigh velocities than that of the substrate steel, while the Ni-P layer with poor wear resistance showed lower velocities. Young`s moduli of the Ni-P layer, estimated so as the computed velocity dispersion agreed with the measured one, increased with the increase of wear resistance. 10 refs., 9 figs., 2 tabs.

  11. Effect of pore water pressure on P-wave velocity in water-filled sands with partial air saturation; Fukanzen howa jotai no suna shiryo wo denpasuru P ha sokudo ni oyobosu kangeki suiatsu no eikyo

    Energy Technology Data Exchange (ETDEWEB)

    Kanema, T [Chishitsu-Keisoku Co. Ltd., Tokyo (Japan)

    1997-10-22

    With an objective to elucidate change in velocity of elastic waves in association with water pressure increase in a sand bed below the groundwater level in a shallow portion of the ground, a measurement experiment was carried out on P-wave velocity in sand samples with partial air saturation. The experiment has used fine sand having an equivalent coefficient of 2.40, a soil particle density of 2.68 g/cm {sup 3} or 60%, and a grain size of 0.36 mm. Inside the water-filled sand sample, two accelerometers were embedded 20 cm apart from each other as vibration receivers. An electromagnetic hammer for P-wave was used as the vibration source. In the experiment, measurement was carried out on the P-wave velocity in association with increase in pore water pressure by applying water pressure afresh to the water-filled sample. As a result of the experiment, the following matters were disclosed: the P-wave velocity increases as the pore water pressure was increased, and a phenomenon was recognized that the dominant frequency changes into high frequency; the degree of increase in the P-wave velocity varies depending on initial saturation of the sample; and bubbles in the pore fluid have their volume decreased due to compression resulted from increased pore water pressure and dissolution of air into the pore water. 6 refs., 11 figs.

  12. Application Security in the ISO27001 Environment

    CERN Document Server

    Vinod, Vasudevan; Firosh, Ummer

    2008-01-01

    Application Security in the ISO27001 Environment demonstrates how to secure software applications within a best practice ISO/IEC 27001 environment and supports implementation of the PCI DSS Payment Application Security Standard.

  13. New ISO standard - personnel photographic film dosemeters

    International Nuclear Information System (INIS)

    Brabec, D.

    1980-01-01

    The ISO Standard 1757 ''Personnel Photographic Film Dosemeters'', issued in June 1980, is briefly described. UVVVR's own dosemeter developed for use in the national film dosimetry service in Czechoslovakia is evaluated in relation to this ISO Standard. (author)

  14. The international ISOE programme. ISOE IAEA technical centre activities

    International Nuclear Information System (INIS)

    Gustafsson, M.

    1996-01-01

    The objective of the sub-programme on Occupational Radiation Protection in the International Atomic Energy Agency, IAEA, is to promote a harmonized approach to optimizing occupational radiation protection by developing guidelines for controlling radiation doses in the workplace and on current occupational radiation protection techniques. A significant part of this programme is the provision of assistance to developing member states to bring their radiation safety infrastructure to an appropriate level for the usage of radiation in the state. In consistence with these objectives the IAEA has been involved with the ISOE programme from its inception and has contributed actively to its growth. In 1993 an arrangement was agreed between the IAEA and the Nuclear Energy Agency, NEA, by which the IAEA co-sponsors ISOE inviting those IAEA member states which are not members of the NEA to participate cost-free in the programme. (author)

  15. ISO specifications and unclear energy quality certification

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Tae Hun

    2011-12-15

    This book indicates necessity of quality management and change of company environment, basic conception of quality management and thinking way, role of each class for quality management, necessity and purpose of introduction of ISO9000 family, authentication process and construct method of ISO9000 family, authentication effect of ISO9000 family, present condition of ISO9000 family, standard of quality certification and quality management and explanation of 2001 requirement of KSA9000.

  16. ISO specifications and unclear energy quality certification

    International Nuclear Information System (INIS)

    Lee, Tae Hun

    2011-12-01

    This book indicates necessity of quality management and change of company environment, basic conception of quality management and thinking way, role of each class for quality management, necessity and purpose of introduction of ISO9000 family, authentication process and construct method of ISO9000 family, authentication effect of ISO9000 family, present condition of ISO9000 family, standard of quality certification and quality management and explanation of 2001 requirement of KSA9000.

  17. The European Large Area ISO Survey

    DEFF Research Database (Denmark)

    Oliver, S.; Rowan-Robinson, M.; Alexander, D.M.

    2000-01-01

    We describe the European Large Area ISO Survey (ELAIS). ELAIS was the largest single Open Time project conducted by ISO, mapping an area of 12 deg(2) at 15 mu m with ISOCAM and at 90 mu m with ISOPHOT. Secondary surveys in other ISO bands were undertaken by the ELAIS team within the fields of the...

  18. ISO27001 in a Windows Environment

    CERN Document Server

    Honan, Brian

    2010-01-01

    Ideal for project managers, IT and security staff, this book plugs the gap in current guidance literature for ISO27001. ISO27001, the information security management standard (ISMS), is providing a significant challenge for many organisations. One of the key areas of confusion is the relationship between the ISO27001 ISMS project manager and those responsible for implementing the technical controls.

  19. Certification of ISO 9001: SSDL experiences

    International Nuclear Information System (INIS)

    Noriah Mod Ali

    2005-01-01

    Efforts given to maintain the quality management based on the ISO 9000 requirement able to improved the existing system, strengthen the customer confidence and to satisfied the worker needs. It gives direct impact on the harmonization of the Radiation Protection Program in the country. SSDL experiences towards obtaining the the ISO 9002/ISO 9001 certification and its maintenance are discussed in details. (Author)

  20. ISO standardization in nuclear technology

    Energy Technology Data Exchange (ETDEWEB)

    Brabec, D [Ustav pro Vyzkum, Vyrobu a Vyuziti Radioisotopu, Prague (Czechoslovakia); Cermak, O [Urad pro Normalizaci a Mereni, Prague (Czechoslovakia)

    1984-10-01

    The activity is described of the technical commission ISO/TC 85 which is currently divided into 4 subcommissions (SC) and 24 working groups. SC 1 ''Terminology, definitions, units, abbreviations'' has one working group. The most important document of this SC is ISO 921-1972 (Dictionary of nuclear technology). SC 2 ''Radiation protection'' has 9 working groups and has processed standards in dosimetry. SC 3 ''Technology of power reactors'' has 6 working groups and its work is related to IAEA activities within the NUSS program. SC 4 ''Technology of nuclear fuels'' has 8 working groups. SC 4 has compiled the basic standards for sealed sources and methods of testing their tightness. The results of the work of this group have been reflected into the standardization work of CMEA. A list is given of published international standards within TC 85.

  1. Explanation and practice on ISO 9000

    International Nuclear Information System (INIS)

    Kwon, Dong Myeong

    2001-01-01

    This book reveals introduction on revision of ISO 9000:2000 with full account and contents of revision and change method change into ISO 9001:2000, the basic principle on ISO 9000:2000 and improvement and aim, definition on explanation, method for detail term, demand for ISO/KS A 9001:2000, quality management system development and transition way, standardization for quality management, manual of quality and making procedure and guide, case of quality manual and procedure and guide and ISO 9001:2000 / KS A 9001:2001 an English-Korean translation.

  2. Range of wavelengths possible to estimate phase velocities of surface waves in microtremors; Bido tansaho ni okeru suitei kanona bidochu no hyomenha iso sokudo no hacho han`i

    Energy Technology Data Exchange (ETDEWEB)

    Miyakoshi, K; Okada, H; Ling, S [Hokkaido University, Sapporo (Japan)

    1996-05-01

    To specify the maximum wavelength of the phase velocities that can be estimated by the spatial autocorrelation (SPAC) method or F-K method in microtremor exploration, investigations were conducted using numerical simulation. In view of feasibility, an equilateral triangle array was employed, the maximum radius of the array having 7 observation points being 0.10km. The dispersion curve of the Rayleigh wave basic mode was calculated from an underground structure model. White noise was used as the incident wave, and, in case the waves came in from multiple directions, a different phase spectrum was assigned to each direction. In searching for the maximum wave length of phase velocities that could be estimated, a limit was imposed upon estimation, and it was prescribed that the wavelength be the limit if the difference between the theoretical value and estimated phase velocity was 5% or higher. As the result, it was found that it is possible to estimate the phase velocity when the wavelength is up to approximately 10 times longer than the array maximum radius in the SPAC method, and up to approximately 5 times longer in case of the F-K method. 10 refs., 5 figs., 1 tab.

  3. ISO standardization in nuclear technology

    Energy Technology Data Exchange (ETDEWEB)

    Brabec, D. (Ustav pro Vyzkum, Vyrobu a Vyuziti Radioisotopu, Prague (Czechoslovakia)); Cermak, O. (Urad pro Normalizaci a Mereni, Prague (Czechoslovakia))

    1984-10-01

    The activity is described of the technical commission ISO/TC 85 which is currently divided into 4 subcommissions (SC) and 24 working groups. SC 1 ''Terminology, definitions, units, abbreviations'' has one working group. The most important document of this SC is ISO 921-1972 (Dictionary of nuclear technology). SC 2 ''Radiation protection'' has 9 working groups and has processed standards in dosimetry. SC 3 ''Technology of power reactors'' has 6 working groups and its work is related to IAEA activities within the NUSS program. SC 4 ''Technology of nuclear fuels'' has 8 working groups. SC 4 has compiled the basic standards for sealed sources and methods of testing their tightness. The results of the work of this group have been reflected into the standardization work of CMEA. A list is given of published international standards within TC 85.

  4. ISO standards on the evaluation of contamination

    International Nuclear Information System (INIS)

    Swinth, K.L.; Tamberg, T.A.

    1993-01-01

    The International Organization for Standardization (ISO) develops radiation calibration standards through Subcommittee 2 (titled ''Radiation Protection'') of Technical Committee 85 (ISO/TC85/SC2). The subcommittee has also developed standards providing guidance on the performance of measurements. ISO/TC85/SC2 consists of international technical experts who represent their countries through the international consensus process in providing guidance in several radiation protection areas. The purpose of this paper is to summarize ISO's is guidance provided in the area of contamination measurements

  5. International Organization for Standardization (ISO) 15189.

    Science.gov (United States)

    Schneider, Frank; Maurer, Caroline; Friedberg, Richard C

    2017-09-01

    The College of American Pathologists (CAP) offers a suite of laboratory accreditation programs, including one specific to accreditation to the international organization for standardization (ISO) 15189 standard for quality management specific to medical laboratories. CAP leaders offer an overview of ISO 15189 including its components, internal audits, occurrence management, document control, and risk management. The authors provide a comparison of its own ISO 15189 program, CAP 15189, to the CAP Laboratory Accreditation Program. The authors conclude with why laboratories should use ISO 15189. © The Korean Society for Laboratory Medicine.

  6. IsoBank workshop held at IsoEcol10 - University of Tokyo 2016

    OpenAIRE

    Hayden, Brian

    2016-01-01

    IsoBank is a repository for stable isotope values and relevant metadata. These slides were presented at a workshop held during IsoEcol10 to refine and design the IsoBank for the needs of a diverse group of researchers.

  7. Laser treatment of plasma sprayed HA coatings

    NARCIS (Netherlands)

    Khor, KA; Vreeling, A; Dong, ZL; Cheang, P

    1999-01-01

    Laser treatment was conducted on plasma sprayed hydroxyapatite (HA) coatings using a Nd-YAG pulse laser. Various laser parameters were investigated. The results showed that the HA surface melted when an energy level of greater than or equal to 2 J and a spot size of 2 mm was employed during

  8. ha õhtu seltskonnalaud / Kaire Nurk

    Index Scriptorium Estoniae

    Nurk, Kaire, 1960-

    2005-01-01

    ha õhtusöömaaja teemast kunstis. Saksa kunstiajaloolase Horst Schwebeli poolt Leonardo da Vinci "Püha õhtusöömaaja" XX sajandi "töötlustes" välja toodud poliitilise agitatsiooni ja ühisest probleemist haaratud seltskonna kujutiste suunast. Laua kujutisest kunstis

  9. Implementation and Impact of ISO 9001

    NARCIS (Netherlands)

    B. Manders (Basak)

    2015-01-01

    markdownabstract__Abstract __ The ISO 9001 quality management standard has been implemented by more than one million organizations in 187 countries since its introduction in 1987. A newer version of ISO 9001 is planned to be introduced in 2015. Even though it is widely used by organizations to

  10. ISO Science Legacy A Compact Review of ISO Major Achievements

    CERN Document Server

    Cesarsky, Catherine J

    2006-01-01

    Stars are born and die in clouds of gas and dust, opaque to most types of radiation, but transparent in the infrared. Requiring complex detectors, space missions and cooled telescopes, infrared astronomy is the last branch of this discipline to come of age. After a very successful sky survey performed in the eighties by the IRAS satellite, the Infrared Space Observatory, in the nineties, brought spectacular advances in the understanding of the processes giving rise to powerful infrared emission by a great variety of celestial sources. Outstanding results have been obtained on the bright comet Hale-Bopp, and in particular of its water spectrum, as well as on the formation, chemistry and dynamics of planetary objects in the solar system. Ideas on the early stages of stellar formation and on the stellar initial mass function have been clarified. ISO is the first facility in space able to provide a systematic diagnosis of the physical phenomena and the chemistry in the close environment of pre-main sequence stars...

  11. Peningkatan Mutu Proses Perguruan Tinggi Melalui Sistem Mutu Iso 9000

    Directory of Open Access Journals (Sweden)

    Th. Widia Soerjaningsih

    2004-09-01

    Full Text Available Article was made to answer these several questions;  what is acreditation and the application in the college; what is ISO 9000 quality system; why is ISO 9000 needed by the college; how ISO 9000 can support the achievement of the defined quality level; how ISO  9000 guarantee the achievement of BAN target including quality, efficiency, and relevance; what is the difference between BAN Acreditation and ISO 9000 Certification; ISO 9000 Consultant: why it is necessary, how to choose it, the line of the contract; ISO 9000 Assessor and the achieve certification: SGS and etc.; and ISO 9000 Certification Proccess Cost Aspect.   

  12. ISO 9001 2000 : the quality management process

    CERN Document Server

    Tricker, Ray

    2006-01-01

    With the publication of ISO 9001:2000, there is now a single quality management ?requirements? standard that is applicable to all organisations, products and services. ISO 9001:2000 is the only standard that can be used for the certification of a QMS and its generic requirements can be used by any organisation.ISO 9001:2000 applies to all types or organisations. It is the quality standard which specifies the requirements of quality management systems for use where organisations need to demonstrate their capability to provide products and services which meet both customer needs and relevant reg

  13. ISO science - observations of dusty discs.

    Science.gov (United States)

    Heske, A.

    1992-12-01

    ISO, the Infrared Space Observatory, will be an infrared observing facility in space. Via submission of observing proposals, use of this facility will be open to the astronomical community. The scientific payload consists of two spectrometers, a camera and a photo-polarimeter. Following an overview of the ISO mission, this paper describes the highlights of the Central Programme - proposals which are being prepared by the instrument groups, the mission scientists and the astronomers of the ISO Science Operations Team - with special emphasis on the proposals concerned with dusty discs.

  14. ISO 14001 ENVIRONMENTAL MANAGEMENT SYSTEMS FOR GOVERNMENT

    Science.gov (United States)

    This presentation provides an overview of the document, ISO 14001 - A Tool for Supporting Government Environmental Programs and Policies, recently published by USEPA/s Office of Research and Development. It is an informational document, explaining the backjground and development ...

  15. ISO developments in the United States

    International Nuclear Information System (INIS)

    Hogan, William W.

    1998-01-01

    An important feature of the restructuring process in the United States is the creation of independent system operators (ISOs) to coordinate dispatch and access to transmission grids. A number of ISOs have been proposed and are summarized here. Perhaps the greatest challenge is the pricing of transmission to give proper economic signals to market participants, and the locational pricing scheme now operating in the PJM system offers the best hope for efficient pricing. (author)

  16. Morphological Effects of HA on the Cell Compatibility of Electrospun HA/PLGA Composite Nanofiber Scaffolds

    Directory of Open Access Journals (Sweden)

    Adnan Haider

    2014-01-01

    Full Text Available Tissue engineering is faced with an uphill challenge to design a platform with appropriate topography and suitable surface chemistry, which could encourage desired cellular activities and guide bone tissue regeneration. To develop such scaffolds, composite nanofiber scaffolds of nHA and sHA with PLGA were fabricated using electrospinning technique. nHA was synthesized using precipitation method, whereas sHA was purchased. The nHA and sHA were suspended in PLGA solution separately and electrospun at optimized electrospinning parameters. The composite nanofiber scaffolds were characterized by FE-SEM, EDX analysis, TEM, XRD analysis, FTIR, and X-ray photoelectron. The potential of the HA/PLGA composite nanofiber as bone scaffolds in terms of their bioactivity and biocompatibility was assessed by culturing the osteoblastic cells onto the composite nanofiber scaffolds. The results from in vitro studies revealed that the nHA/PLGA composite nanofiber scaffolds showed higher cellular adhesion, proliferation, and enhanced osteogenesis performance, along with increased Ca+2 ions release compared to the sHA/PLGA composite nanofiber scaffolds and pristine PLGA nanofiber scaffold. The results show that the structural dependent property of HA might affect its potential as bone scaffold and implantable materials in regenerative medicine and clinical tissue engineering.

  17. Application of forking genetic algorithm to the estimation of an S-wave-velocity structure from Rayleigh-wave dispersion data. With special reference to an exploration method using microtremors; Rayleigh ha no bunsan data kara S ha sokudo kozo wo suiteisuru inversion mondai eno kotaigun tansaku bunkigata identeki algorithm no tekiyo. Bido tansaho ni kanrenshite

    Energy Technology Data Exchange (ETDEWEB)

    Cho, I; Nakanishi, I [Kyoto University, Kyoto (Japan); Ling, S [Nihon Nessui Corp., Tokyo (Japan); Okada, H [Hokkaido University, Sapporo (Japan)

    1997-10-22

    Discussions were given on a genetic algorithm as a means to solve simultaneously the problems related to stability of solution and dependence on an initial model in estimating subsurface structures using the microtremor exploration method. In the study, a forking genetic algorithm (fGA) to explore solid substance groups was applied to the optimizing simulations for a velocity structure model to discuss whether the algorithm can be used practically. The simulation No. 1 was performed by making the number of layers four for both of the given velocity structure and the optimizing model. On the other hand, the simulation No. 2 was executed by making the number of layers for the given velocity structure greater than that for the optimizing model. As a result, it was verified that wide range exploration may be possible for the velocity structure model, and that a large number of candidates for the velocity structure model may be proposed. In either case, the exploration capability of the fGA exceeded that of the standard simple genetic algorithm. 8 refs., 4 figs., 2 tabs.

  18. Sterilisation effect study on granular hydroxyapatite (HA)

    International Nuclear Information System (INIS)

    Saidu, M.F.; Mashita, M.; Khadijah, K.; Fazan, F.; Khalid, K.A.

    2004-01-01

    Hydroxyapatite (HA) is a calcium phosphate bio ceramic that has been shown by many authors to be biocompatible with bioactive properties. It is widely accepted as the best synthetic material available for surgical use as a bone graft substitute. HA granules produced by Amerce-SIRIM from local materials underwent 5 types of sterilisation techniques with different ageing periods. Samples were tested for chemical and phase composition and microbial contamination before and after being sterilised. From the microbiological tests done, none of the unsterilised positive control yielded a positive culture. Results from X-Ray diffraction studies found that all the sterilisation techniques did not chemically degrade or structurally change the HA granules significantly. (Author)

  19. Aplikace ISO norem v oblasti vývoje softwaru

    OpenAIRE

    Ullrich, Jan

    2007-01-01

    Thesis evaluates ISO standars used for software developement and their relationship to methodologies. It also describes processes according to international standard ISO/IEC 12207 and quality management systems according to ISO 9000. It evaluates also mothodlogy RUP and agile methodollogies. The goal of the thesis to tailor processes related to ISO 9001 to be compliant to the ISO/IEC 12207 in a small company.

  20. IS ISO 9000 CERTIFICATION LOSING ITS CREDIBILITY?

    Directory of Open Access Journals (Sweden)

    P.R. Ramesh

    2013-03-01

    Full Text Available ISO certification was a great hope for many stakeholders in India for making the country strong in terms of quality practices. It was a blessing in disguise when in early nineties; buyers were imposing conditions that you should be ISO compliant to do business with them. ISO was a great system to bring in improvements in the way an organization functions. But unfortunately some have adopted a short cut approach in getting the certification done. It is only just before the audit team comes for re-inspection that firms start removing dust from the quality manual files so that they can pretend that that they follow those systems. But a real commitment to adhering to these systems is missing. The paper describes such scenario existing in some quarters in India and warns against such practices for the overall good of the system.

  1. Implications of ISO 9000 for personnel dosimetry

    International Nuclear Information System (INIS)

    Yoder, R.C.

    1995-01-01

    Landauer, Inc. has gained approval to provide personnel dosimetry services in several countries. Each experiene reflects the different concerns adopted by national approval agencies. None have adopted ISO 9000 registration as evidence of a suitable quality system of management. Instead, each organization has prepared its own set of requirements with no provisions for recognizing the results of performance tests or audits conducted by other approval organizations. As ISO 9000 has become a communication symbol for commercial organizations dealing with each other, it has not been similarly viewed by radiation regulation bodies. A key reason arises from a tradition to regulate bodies. A key reason arises from a tradition to regulate, not promote, international trade, not encourage innovation, nor foster economic competition. A second reason is the inability to separate the technical requirements from quality assurance. ISO 9000 may become useful once the national technical organizations learn to trust those of other countries

  2. Tietoturvallisuusauditointi ISO 27000-viitekehyksessä

    OpenAIRE

    Luoma, Ilmari

    2015-01-01

    Tiedon olemassaolo eri olomuodoissa muodostaa vaikeasti hallittavan uhkakentän, jonka käsittelyyn kansainvälisesti hyväksytty ISO 27000 -standardi on hyvä väline. Työn tarkoitus on perehtyä ISO/IEC 27000 -standardisarjaan, soveltaa standardin vaatimuksia laatimalla tietoturvallisuuden auditointiaineisto ja -menetelmä, sekä toteuttaa tietoturvallisuusauditointi käytännössä. Työssä esitellään tietoturvallisuuden kytkeytyminen yritysturvallisuuteen, tietoturvallisuuden osa-alueittainen ...

  3. Sifting through the ISO 9000 maze

    International Nuclear Information System (INIS)

    Abraham, K.S.

    1993-01-01

    Various forces in the global upstream market are more frequently pressuring equipment and services firms to be certified according to the latest international standards in order to do business. However, understanding and completing the registration process can appear confusing and intimidating at first glance. This paper reviews the ISO's 9000 series of generic standards that provide quality assurance requirements and management guidance. It describes its applicability to the oil and gas industry which often found itself cut out of international markets because they were not recognized as registered ISO participants. It then describes the registration process, evaluation process, and time tables involved. It also describes the difference performance standards of the 9000 series

  4. Internal Audit Status For ISO 9001 And ISO/ IEC 17025 In Malaysian Nuclear Agency

    International Nuclear Information System (INIS)

    Fazila Said; Nurul Huda Mudri; Nik Arlina Ali

    2012-01-01

    The development of MS ISO 9001 and MS ISO/ IEC 17025 in Malaysian Nuclear Agency is the basic step to enhance and improve the Quality Management System (QMS) for processes and laboratories that involve customers and suppliers in delivering products and services. The effectiveness of QMS is monitored by Research and Innovation Management Centre (RIMC) to ensure that all activities related to audit such as Internal Audit are well organized and implemented as documented in quality manual and procedure. This paper will discuss the status of internal audit for processes that implement MS ISO 9001 and laboratories that accredited with MS/ ISO IEC 17025 in year 2008, 2009 and 2010. The total of non-conformance (nc) and opportunity for improvement (ofi) for processes and laboratories and their numbers as per clause in MS ISO 9001 and MS ISO/ IEC 17025 are the indicators that reflects the effectiveness of QMS. Then, the total effectiveness of QMS for MS 9001 and MS ISO/ IEC 17025 is also determined via the number of conformance clause versus non-conformance clause for those three years. (author)

  5. ISO certification pays off in quality improvement

    International Nuclear Information System (INIS)

    Vermeer, F.J.G.

    1992-01-01

    This paper reports that by obtaining and maintaining International Standards Organization (ISO) 9001 certification, a company can improve its quality control system, cut waste, and motivate its employees. In so doing it improves its competitive position in both international and domestic markets. The success of a number of countries (notably Japan) in the world markets has focused the attention of the industrialized countries on improving quality levels and striving for a unified, worldwide quality standard. This has been particularly true in Europe; with several countries competing in a single market, a common quality standard has been a highly desirable goal for decades. One of the first multinational quality standards evolved in the European Community, which is estimated to become a single market with a gross national product of $4.5 trillion by 1992. As a consequence, in 1987 the International Standards Organization created ISO 9000, a single standard to ensure uniform quality in products and services offered with this growing market. U.S. petroleum and natural gas companies must recognize and implement the ISO 9000 standards or possibly lose international markets. If the present worldwide trend towards ISO 9000 continues (and there is no reason to believe that it will not), the standards will be just as important in the domestic market

  6. API and ISO standards can be combined

    International Nuclear Information System (INIS)

    Weightman, R.T.; Warnack, M.F.

    1992-01-01

    This paper reports that oil field equipment and product manufacturers can maintain a competitive advantage and minimize costs by integrating American Petroleum Institute (API) licensing programs with International Standards Organization (ISO) 9001 standards under one quality system. A combined quality system approach can position a company for quality system certification under ISO 9001 while maintaining API specifications. Furthermore, only one quality system manual is needed for API licensing and ISO certification, avoiding duplication of effort. The benefits of a documented quality program include the flowing: Job descriptions and personnel qualification requirements are documented; The improved documentation allows direct tracing of specific production activities; Laboratory test methods and calibration of test equipment follow accepted standards for more reliable and reproducible test data; Quality control becomes proactive, not reactive, through internal process controls previously not implemented; Employee attitudes improve through appreciation for the overall goals of the company; Ambiguous quality issues, such as documenting special customer requirements, are easily resolved; and The company image improves with customers, particularly for those that require API Specification Q1 or ISO 9001 compliance or those having their own quality performance standards

  7. ISO sertifikaat aitab otsustada / Toomas Udu

    Index Scriptorium Estoniae

    Udu, Toomas

    2005-01-01

    Ilmunud ka: Delovõje Vedomosti : Transport i logistika 25. mai lk. 8. Teenuse kvaliteedi näitajad logistikafirmas ISO standardi alusel. Vt. samas: Eestis kasutatakse kolme kvaliteedistandardit; Kuidas mõjutada kvaliteeti läbi juhtimissüsteemi

  8. New ISO standards for hearing protectors (A)

    DEFF Research Database (Denmark)

    Poulsen, Torben

    2000-01-01

    Working Group 17 under ISO/TC43/SC1 deals with measurement of hearing protector attenuation. WG17 is presently involved in revision of the present 4869-1 standard (especially sound field requirements and reproducibility estimations) and formulation of a new standard where inexperienced hearing...

  9. Interpretation of MS ISO/ IEC 17020

    International Nuclear Information System (INIS)

    Mohamad Pauzi Ismail

    2012-01-01

    MS ISO/ IEC 17020 is an international standard which adopted by Malaysian Standard states the requirement criteria for inspection bodies. The author involved in the NDT technical assessment to several NDT companies in Malaysia. The experience in performing NDT assessment activity is explained and discussed. (author)

  10. Effect of humic acid (HA) on sulfonamide sorption by biochars

    International Nuclear Information System (INIS)

    Lian, Fei; Sun, Binbin; Chen, Xi; Zhu, Lingyan; Liu, Zhongqi; Xing, Baoshan

    2015-01-01

    Effect of quantity and fractionation of loaded humic acid (HA) on biochar sorption for sulfonamides was investigated. The HA was applied in two different modes, i.e. pre-coating and co-introduction with sorbate. In pre-coating mode, the polar fractions of HA tended to interact with low-temperature biochars via H-bonding, while the hydrophobic fractions were likely to be adsorbed by high-temperature biochars through hydrophobic and π-π interactions, leading to different composition and structure of the HA adlayers. The influences of HA fractionation on biochar sorption for sulfonamides varied significantly, depending on the nature of interaction between HA fraction and sorbate. Meanwhile, co-introduction of HA with sulfonamides revealed that the effect of HA on sulfonamide sorption was also dependent on HA concentration. These findings suggest that the amount and fractionation of adsorbed HA are tailored by the surface properties of underlying biochars, which differently affect the sorption for organic contaminants. - Highlights: • Effect of quantity and fractionation of coated HA on sorption of sulfonamides by BC was studied. • Fractionation of coated HA is tailored by surface properties of BC. • Roles of HA in BC sorption depend on interaction between HA adlayer and sorbate. • Roles of HA in sulfonamide sorption by BC also depend on HA aqueous concentration. - The quantity and fractionation of adsorbed HA play a major role in sulfonamide sorption by biochars

  11. Influencia de la corrupción en la implantación de la ISO 9001

    OpenAIRE

    Olga Rodriguez Arnaldo; Angel R. Martinez Lorente

    2014-01-01

    En las últimas dos décadas, el número de empresas certificadas por ISO 9001 ha ido creciendo constantemente llegando a finales de 2011 a más de 1,1 millones en todo el mundo (ISO, 2012). Sin embargo, la distribución de certificados entre los países no coincide con el peso que cada uno tiene en la economía global. Este artículo comienza con una breve revisión de la literatura sobre las razones por las que las empresas implantan un sistema de gestión que se ajusta a la norma ISO 9001. Esta revi...

  12. Significance of ISO 9000 Quality Management System for ...

    African Journals Online (AJOL)

    Significance of ISO 9000 Quality Management System for Performance ... of ISO 9000 Quality Management System implementation for performance improvement. ... to find out the relationship between certification and process variability.

  13. ISO's analysis of Comet Hale-Bopp

    Science.gov (United States)

    1997-03-01

    The European Space Agency's Infrared Space Observatory ISO inspected Comet Hall-Bopp during the spring and autumn of 1996. The need to keep ISO's telescope extremely cold restricts the spacecraft's pointing in relation to the Sun and the Earth and it ruled out observations at other times. The analyses of the 1996 observations are not yet complete, but already they give new insight into the nature of comets. Comet Hale-Bopp is believed to be a large comet with a nucleus up to 40 kilometres wide. It was discovered in July 1995 by two American astronomers working independently, Alan Hale and Thomas Bopp. At that time, the comet was a billion kilometres away from the Sun, but 200 times brighter than Halley's Comet was, when at a comparable distance. Comet Hale-Bopp will make its closest approach to the Earth on 22 March, and its closest approach to the Sun (perihelion) on 1 April 1997. Some scientific results from ISO The discovery of Comet Hale-Bopp occurred before ISO's launch in November 1995. When first observed by ISO in March and April 1996, the comet was still 700 million kilometres from the Sun, and almost as far from the Earth and ISO. With its privileged view of infrared wavebands inaccessible from the Earth's surface, ISO's photometer ISOPHOT discovered that carbon dioxide was an important constituent of the comet's emissions of vapour.ISOPHOT measured the temperature of the dust cloud around Comet Hale-Bopp. In March 1996, when the comet was still more than 700 million kilometres from the Sun, the dust cloud was at minus 120 degrees C. When ISOPHOT made similar observations in October 1996, the comet was 420 million kilometres from the Sun, and the dust cloud had warmed to about minus 50 degrees C. Intensive observations of Comet Hale-Bopp were also made by ISO's Short-Wave Spectrometer SWS, the Long-Wave Spectrometer LWS, and the ISOPHOT spectrometer PHOT-S. Results are due for publication at the end of March. They will give details about the composition

  14. ISO Results Presented at International Astronomical Union

    Science.gov (United States)

    1997-08-01

    Some of the work being presented is collected in the attached ESA Information Note N 25-97, ISO illuminates our cosmic ancestry. A set of six colour images illustrating various aspects have also been released and are available at http://www.estec.esa.nl/spdwww/iso1808.htm or in hard copy from ESA Public Relations Paris (fax:+33.1.5369.7690). These pictures cover: 1. Distant but powerful infrared galaxies 2. A scan across the milky way 3. Helix nebula: the shroud of a dead star 4. Supernova remnant Cassiopeia A 5. Trifid nebula: a dusty birthplace of stars 6. Precursors of stars and planets The International Astronomical Union provides a forum where astronomers from all over the world can develop astronomy in all its aspects through international co-operation. General Assemblies are held every three years. It is expected that over 1600 astronomers will attend this year's meeting, which is being held in Kyoto, Japan from 18-30 August. Further information on the meeting can be found at: www.tenmon.or.jp/iau97/ . ISO illuminates our cosmic ancestry The European Space Agency's Infrared Space Observatory, ISO, is unmatched in its ability to explore and analyse many of the universal processes that made our existence possible. We are children of the stars. Every atom in our bodies was created in cosmic space and delivered to the Sun's vicinity in time for the Earth's formation, during a ceaseless cycle of birth, death and rebirth among the stars. The most creative places in the sky are cool and dusty, and opaque even to the Hubble Space Telescope. Infrared rays penetrating the dust reveal to ISO hidden objects, and the atoms and molecules of cosmic chemistry. "ISO is reading Nature's recipe book," says Roger Bonnet, ESA's director of science. "As the world's only telescope capable of observing the Universe over a wide range of infrared wavelengths, ISO plays an indispensable part in astronomical discoveries that help to explain how we came to exist." This Information Note

  15. Characterization of New PEEK/HA Composites with 3D HA Network Fabricated by Extrusion Freeforming

    Directory of Open Access Journals (Sweden)

    Mohammad Vaezi

    2016-05-01

    Full Text Available Addition of bioactive materials such as calcium phosphates or Bioglass, and incorporation of porosity into polyetheretherketone (PEEK has been identified as an effective approach to improve bone-implant interfaces and osseointegration of PEEK-based devices. In this paper, a novel production technique based on the extrusion freeforming method is proposed that yields a bioactive PEEK/hydroxyapatite (PEEK/HA composite with a unique configuration in which the bioactive phase (i.e., HA distribution is computer-controlled within a PEEK matrix. The 100% interconnectivity of the HA network in the biocomposite confers an advantage over alternative forms of other microstructural configurations. Moreover, the technique can be employed to produce porous PEEK structures with controlled pore size and distribution, facilitating greater cellular infiltration and biological integration of PEEK composites within patient tissue. The results of unconfined, uniaxial compressive tests on these new PEEK/HA biocomposites with 40% HA under both static and cyclic mode were promising, showing the composites possess yield and compressive strength within the range of human cortical bone suitable for load bearing applications. In addition, preliminary evidence supporting initial biological safety of the new technique developed is demonstrated in this paper. Sufficient cell attachment, sustained viability in contact with the sample over a seven-day period, evidence of cell bridging and matrix deposition all confirmed excellent biocompatibility.

  16. Characterization of New PEEK/HA Composites with 3D HA Network Fabricated by Extrusion Freeforming.

    Science.gov (United States)

    Vaezi, Mohammad; Black, Cameron; Gibbs, David M R; Oreffo, Richard O C; Brady, Mark; Moshrefi-Torbati, Mohamed; Yang, Shoufeng

    2016-05-26

    Addition of bioactive materials such as calcium phosphates or Bioglass, and incorporation of porosity into polyetheretherketone (PEEK) has been identified as an effective approach to improve bone-implant interfaces and osseointegration of PEEK-based devices. In this paper, a novel production technique based on the extrusion freeforming method is proposed that yields a bioactive PEEK/hydroxyapatite (PEEK/HA) composite with a unique configuration in which the bioactive phase (i.e., HA) distribution is computer-controlled within a PEEK matrix. The 100% interconnectivity of the HA network in the biocomposite confers an advantage over alternative forms of other microstructural configurations. Moreover, the technique can be employed to produce porous PEEK structures with controlled pore size and distribution, facilitating greater cellular infiltration and biological integration of PEEK composites within patient tissue. The results of unconfined, uniaxial compressive tests on these new PEEK/HA biocomposites with 40% HA under both static and cyclic mode were promising, showing the composites possess yield and compressive strength within the range of human cortical bone suitable for load bearing applications. In addition, preliminary evidence supporting initial biological safety of the new technique developed is demonstrated in this paper. Sufficient cell attachment, sustained viability in contact with the sample over a seven-day period, evidence of cell bridging and matrix deposition all confirmed excellent biocompatibility.

  17. An introduction to information security and ISO27001:2013

    CERN Document Server

    Watkins, Steve

    2013-01-01

    Up to date with the latest version of the Standard (ISO27001:2013), An Introduction to information security and ISO27001:2013 is the perfect solution for anyone wanting an accurate, fast, easy-to-read primer on information security from an acknowledged expert on ISO27001.

  18. The Relationship between the Training Function and ISO-9000 Registration.

    Science.gov (United States)

    Maxwell, Randy C.; Jost, Karen L.

    ISO 9000 is one of a series of international standards providing guidelines and governing quality of products and services. The ISO 9000 certification demonstrates the capability of a supplier to control the processes that determine the acceptability of the product or service being supplied. This paper focuses on the training aspects of ISO 9000…

  19. ISO 14000 and the nuclear licensing

    International Nuclear Information System (INIS)

    Martins, Nadia Soido Falcao

    1999-01-01

    As concern grows for maintaining and improving the quality of the environment and protecting human health, all the world is turning its attention to the potential environmental in pact of their industrial activities. One of the most important contribution in that way is the International Standard ISO 14000 series. In the utilization of nuclear energy, right from the inception, the safety of personnel, environment and the population has been the basic consideration. Over the years well established licenses criteria have been proposed to limit and control the environmental impact of the plant operation and emergencies situation. In this paper are discussed some specific requirements for implementation of the environmental management system specified by ISO 14000 compared to the environmental requirements for nuclear licensing. (author)

  20. The ISO9000 standard in electrical research

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez-Ortiz, G.; Davila-Nunez, G.; Gonzalez-Sustaeta, J. [Inst. de Investigaciones Electricas, Cuernavaca (Mexico). Unidad de Sistemas Informaticos

    1999-11-01

    In this article, the main aspects that are considered important upon applying the ISO9000 standard [ISO 94] in a research institution, company, or group, are described. The 20 sections of the standard are discussed emphasizing the concepts and definitions that can be differently interpreted in the process of elaboration of a quality manual for a group devoted to research, than when they are applied in the elaboration of a manual for a factory that produces material goods. The exposed reasoning was used in the elaboration of the quality manual in the Information Systems Unit of the Electrical Research Institute in Mexico, and it is being used in the installation and operation of the quality system.

  1. Incorporating ISO Metadata Using HDF Product Designer

    Science.gov (United States)

    Jelenak, Aleksandar; Kozimor, John; Habermann, Ted

    2016-01-01

    The need to store in HDF5 files increasing amounts of metadata of various complexity is greatly overcoming the capabilities of the Earth science metadata conventions currently in use. Data producers until now did not have much choice but to come up with ad hoc solutions to this challenge. Such solutions, in turn, pose a wide range of issues for data managers, distributors, and, ultimately, data users. The HDF Group is experimenting on a novel approach of using ISO 19115 metadata objects as a catch-all container for all the metadata that cannot be fitted into the current Earth science data conventions. This presentation will showcase how the HDF Product Designer software can be utilized to help data producers include various ISO metadata objects in their products.

  2. Promoting Strong ISO 50001 Outcomes with Supportive National Infrastructure

    Energy Technology Data Exchange (ETDEWEB)

    McKane, Aimee, T.; Siciliano, Graziella; de los Reyes, Pamela

    2015-08-04

    The ISO 50001 standard is a key mechanism for reducing greenhouse gas emissions and improving energy efficiency globally. An increasing number of companies are seeking certification, creating the need for personnel that are competent to conduct ISO 50001 certification audits. The growth of ISO 50001 is expected to accelerate as more companies integrate ISO 50001 into their corporate sustainability strategies and supplier requirements. Robust implementation of ISO 50001 represents an important tool for countries with climate change mitigation goals. Because of its dual focus on continual improvement of an organization’s energy management system (EnMS) and its energy performance improvement, ISO 50001 requires skills of both implementers and certification auditors that are not well-supported by current credentials and training. This paper describes an effort to address skill gaps of certification auditors, a critical factor to ensure that ISO 50001 implementations are robust and result in continued energy performance improvement. A collaboration of governments through the Energy Management Working Group (EMWG), formerly under Global Superior Energy Performance (GSEP), has formed to build workforce capacity for ISO 50001 certification audits. The EMWG is leading the development of an internationally-relevant certification scheme for ISO 50001 Lead Auditor that meets requirements for ISO/IEC 17024 accreditation and ISO 50003 for defining ISO 50001 Lead Auditor competency. Wider availability of competent ISO 50001 Lead Auditors will ultimately increase the impact and market value of ISO 50001 certification and improve consistency of ISO 50001 certification outcomes by establishing a standardized and high level of knowledge and skills globally.

  3. ISO 55000: Creating an asset management system.

    Science.gov (United States)

    Bradley, Chris; Main, Kevin

    2015-02-01

    In the October 2014 issue of HEJ, Keith Hamer, group vice-president, Asset Management & Engineering at Sodexo, and marketing director at Asset Wisdom, Kevin Main, argued that the new ISO 55000 standards present facilities managers with an opportunity to create 'a joined-up, whole lifecycle approach' to managing and delivering value from assets. In this article, Kevin Main and Chris Bradley, who runs various asset management projects, examine the process of creating an asset management system.

  4. Revision of ISO 15859 Aerospace Fluid Standards

    Science.gov (United States)

    Greene, Benjamin; McClure, Mark B.

    2012-01-01

    A detailed review of ISO 15859 "Space Systems - Fluid Characteristics, Sampling and Test Methods" was performed An approach to revising Parts 1-9 and 11-13 was developed and concurred by the NASA Technical Standards Program Office. The approach was to align them with the highest level source documents, and not to program-specific requirements. The updated documents were prepared and presented.

  5. 75 FR 7581 - RTO/ISO Performance Metrics; Notice Requesting Comments on RTO/ISO Performance Metrics

    Science.gov (United States)

    2010-02-22

    ... performance communicate about the benefits of RTOs and, where appropriate, (2) changes that need to be made to... of staff from all the jurisdictional ISOs/RTOs to develop a set of performance metrics that the ISOs/RTOs will use to report annually to the Commission. Commission staff and representatives from the ISOs...

  6. ISO: international standards development for nuclear technology

    International Nuclear Information System (INIS)

    Becker, K.

    1981-01-01

    The importance of internationally recognized standards for nuclear technology and safety is rapidly increasing for technical as well as economical and political reasons such as public acceptance and nuclear technology transfer to developing countries. The need for such standards is also evident because of the large number of nuclear installations sited close to international borders, and the export of nuclear installations from relatively few supplier countries to a large number of user countries. It is the purpose of this report to describe briefly the history, organizational structures and procedures, goals, accomplishments, problems, and future needs of the relevant activities of the International Organization for Standardization (ISO). ISO is composed of the partly governmental, partly non-governmental national standards bodies of 86 countries including China. The work of its Technical Committee (TC) 85 'Nuclear Energy' is mostly concerned with industrial applications, contractual aspects and international communication, for the benefit of both developed and developing countries. It works in close liaison with IAEA, which develops Codes and Guides addressed mainly to the regulatory aspects of nuclear power plants in developing countries. ISO/TC 85 has four sub-committees dealing with: (a) Terminology, Definitions, Units and Symbols (Secretariat USA, four working groups (WGs)); (b) Radiation Protection (Secretariat France, ten WGs); (c) Power Reactor Technology (Secretariat Sweden, nine WGs); (d) Nuclear Fuel Technology (Secretariat F.R. Germany, seven WGs). (author)

  7. The current status of radiopharmacy laboratories in Turkey, conveniences to good radiopharmacy practice (GRP) and quality management systems (ISO)

    International Nuclear Information System (INIS)

    Atak, I.E.

    2004-01-01

    This study ha been conducted in the Radiopharmacy Laboratories of Nuclear Medicine departments of various hospitals and private nuclear medicine laboratories. A total of 35 laboratories from 7 regions of Turkey have been selected by layered sampling method from 131 Radiopharmacy Laboratories located in 30 different cities. During the study, a GRP investigation list with 67 questions and direct communication technique have been used. The aim was determine the current status of the Radiopharmacy Laboratories in general and the administration of radiopharmaceuticals on patients, and good practices in radiopharmacy and conformance with quality assurance systems. In this respect, questions have been asked to determine a) General status, b) Information level of lab workers regarding to the GRP and ISO concepts (i-Status of lab managers, ii- Responsibilities and knowledge of lab workers and iii- regarding to GRP and ISO-9000), c) Conditions of infrastructure, and lab services and its quality, d) Status of organizations. Results showed that only two of the 35 managers of laboratories were radiopharmacists, the rest were Nuclear Medicine specialists. There were less knowledge on GRP than ISO, the labs holding ISO certificate were in minority even though ISO is known concept, radiopharmacist were more knowledgeable in GRP while nuclear medicine specialists were in ISO, the labs with better GRP knowledge have better infrastructure, the GRP knowledge were better in the university and armed forces hospitals while ISO knowledge and certificates were more in private labs and hospitals, the armed forces hospitals better paraphernalia, practically almost all radiopharmaceutical kits were imported goods and there were important problems in quality control

  8. Laadun- ja riskienhallinta johtamisjärjestelmässä ISO 9001:2015 ja ISO 31000:2009 mukaisesti

    OpenAIRE

    Reinvall, Niko; Karhunen, Joonas

    2015-01-01

    Tämän opinnäytetyön tarkoituksena on tarkastella riskienhallinnan ja laadunhallintajärjestelmien suhdetta ISO 9001:2015 ja ISO 31000:2009-standardien viitekehyksessä, tutkimuskysymyksen ollessa ”miten ja miksi integroida ISO 9001 mukaista laadunhallintaa ja ISO 31000 mukaista riskienhallintaa organisaation johtamisjärjestelmään”. Lisäksi työssä tarkastellaan standardien välisiä yhtymäkohtia ja riskienhallinnan merkitystä ISO 9001:2015 mukaisessa laadunhallintajärjestelmässä. Työn tilaaja...

  9. Metrological management evaluation based on ISO10012: an empirical study in ISO-14001-certified Spanish companies

    International Nuclear Information System (INIS)

    Beltran, Jaime; Rivas, Miguel; Munuzuri, Jesus; Gonzalez, Cristina

    2010-01-01

    Environmental management systems based on the ISO 14001 standard rely strongly on metrological measurement and confirmation processes to certify the extent to which organizations monitor and improve their environmental behavior. Nevertheless, the literature lacks in studies that assess the influence of these metrological processes on the performance of environmental management in organizations, even now that the international standard ISO 10012 is already available to establish requisites and guidelines for the development of a metrological management system that is compatible with any other standardized management system. This work seeks to assess that influence through the development of an evaluation model for metrological management, which is then validated through an experimental analysis of the results obtained from the application of an audit process in 11 Spanish companies, all ISO-14001-certified and operating in different industrial sectors. (author)

  10. A graded approach to ISO 9000 implementation for records managers

    Energy Technology Data Exchange (ETDEWEB)

    Pasterczyk, C.E.

    1994-08-01

    ISO 9000 is a series of quality system standards developed by Technical Committee 176 of the International Standards Organization. The series includes three standards, ISO 9001 `Quality systems--Model for quality assurance in design/development, production, installation and serving,` ISO 9002 `Quality systems--Model for quality assurance in production and installation,` ISO 9003 `Quality systems--Model for quality assurance in final inspection and test,` and two guidelines, ISO 9000 `Quality management and quality assurance standards` and ISO 9004 `Quality management and quality system elements--Guidelines.` In companies with quality programs already in place, the structure of the ISO series lends itself to augmenting those policies, procedures, and instructions where problems exist or where the risks of failure are greater. The objectives of this paper are to provide a basic familiarity to ISO 9000 and quality assurance concepts; provide a higher level of familiarity to the records management and document control portions of the ISO 9000 series; and to discuss a graded approach to meeting the intent of ISO 9000.

  11. Lean principles adoption in environmental management system (EMS - ISO 14001

    Directory of Open Access Journals (Sweden)

    Perumal Puvanasvaran

    2012-12-01

    Full Text Available Purpose: The purpose of this study is to examine the characteristic of the lean principles into ISO 14001 and to propose linkage of the lean principles and ISO 14001.Design/methodology/approach: To achieve the objective of the study, literature survey and quantitative research method using questionnaires survey are used.Findings and Originality/value: The findings of this study confirm that ISO 14001 certified company adopted lean production practices.  The study also proves that lean principles have positive and significant relationship with ISO 14001 EMS and the linkage can be made between lean principles and ISO 14001 to achieve Continual Improvement.Research limitations/implications: The small sizes of the sample of the participating companies are the main limitations of this study and this research mainly focuses on the manufacturing environment and services industry.Practical implications: This research show that all ISO 14001 companies do adopt at least one lean production practices and the main findings are lean principles has positive and highly significant relationship with ISO 14001 requirements.  This is because the integration of lean principles into ISO 14001 will serve practical methods for ISO14001 EMS to achieve the continual improvement.Originality/value: This research is amongst the first to study the combined lean principles with ISO 1400.  Based on the current situation, there is no integration within this two management system. 

  12. ISO 639-1 and ISO 639-2: International Standards for Language Codes. ISO 15924: International Standard for Names of Scripts.

    Science.gov (United States)

    Byrum, John D.

    This paper describes two international standards for the representation of the names of languages. The first (ISO 639-1), published in 1988, provides two-letter codes for 136 languages and was produced primarily to meet terminological needs. The second (ISO 639-2) appeared in late 1998 and includes three-letter codes for 460 languages. This list…

  13. Norma ISO 690:2010 [Doctorado. 2015

    OpenAIRE

    Biblioteca Universitaria

    2015-01-01

    Mediante el estudio de este tema aprenderás a gestionar adecuadamente tu bibliografía adquiriendo una serie de competencias que te permitirán: - Actuar de manera responsable, ética y legal en el uso de la información empleada para realizar un trabajo académico. - Identificar el estilo de cita más adecuado para cada disciplina científica. - Identificar correctamente y elaborar las referencias bibliográficas correspondientes a distintos tipos de documentos, de acuerdo con la norma ISO 690:2010....

  14. Norma ISO 690:2010 [Doctorado. 2017

    OpenAIRE

    Biblioteca Universitaria

    2017-01-01

    Mediante el estudio de este tema aprenderás a gestionar adecuadamente tu bibliografía adquiriendo una serie de competencias que te permitirán: - Actuar de manera responsable, ética y legal en el uso de la información empleada para realizar un trabajo académico. - Identificar el estilo de cita más adecuado para cada disciplina científica. - Identificar correctamente y elaborar las referencias bibliográficas correspondientes a distintos tipos de documentos, de acuerdo con la norma ISO 690:2010....

  15. Norma ISO 690:2010 [Doctorado. 2014

    OpenAIRE

    Biblioteca Universitaria

    2014-01-01

    Mediante el estudio de este tema aprenderás a gestionar adecuadamente tu bibliografía adquiriendo una serie de competencias que te permitirán: - Actuar de manera responsable, ética y legal en el uso de la información empleada para realizar un trabajo académico. - Identificar el estilo de cita más adecuado para cada disciplina científica. - Identificar correctamente y elaborar las referencias bibliográficas correspondientes a distintos tipos de documentos, de acuerdo con la norma ISO 690:2010....

  16. Cotation de fabrication avec les normes ISO

    CERN Document Server

    Anselmetti, Bernard

    2010-01-01

    La cotation ISO en production impose de nouvelles méthodologies pour élaborer les documents de maîtrise de la qualité géométrique des produits : les dessins de phase, du brut et d'états intermédiaires pour la conformité des pièces et les fiches de production, de réglage, de contrôle et de surveillance pour la conformité des moyens de production. Une méthode de transfert unidirectionnelle simple permet d'établir des dessins de phase en normes ISO et d'optimiser la répartition des tolérances à isocapabilité. Cette cotation est déclinée en cotation d'état intermédiaire, de production et de réglage. Une méthode tridimensionnelle est proposée pour prendre en compte les effets des défauts angulaires. Une maquette montre les fonctionnalités envisageables pour les futurs outils d'aides au tolérancement de fabrication au sein de la CFAO. De nombreux exercices illustrent les différentes démarches. Ce Manuel de tolérancement est principalement destiné aux préparateurs méthodes et aux c...

  17. Adhesive strength of hydroxyl apatite(HA) coating and biomechanics behavior of HA-coated prosthesis:an experimental study

    OpenAIRE

    Tian-yang ZHANG; Yong-hong DUAN; Shu ZHU; Jin-yu ZHU; Qing-sheng ZHU

    2011-01-01

    Objective To explore the influence of adhesive strength of hydroxyapatite(HA) coating on the post-implantation stability of HA-coated prosthesis.Methods The adhesive strength and biomechanics behavior of HA coating were studied by histopathological observation,material parameters and biomechanical testing,the titanium(Ti)-coated prosthesis was employed as control.Results Scratch test showed that the adhesive strength of HA coating was significantly lower than that of Ti coating(P < 0.01).Hist...

  18. Die bestuur en opleiding van SABS ISO 9000 reeks

    OpenAIRE

    2014-01-01

    With the lifting of sanctions, South African businesses are faced with a new challenge to compete against their international counterparts on the international and domestic markets. Competing on the international markets is dependant on conforming to a recognised quality management system standard such as ISO 9000 (ISO International Standards Organisation). The South African equivalent for this standard is SABS ISO 9000. (SABS - South African Bureau of Standards). It is thus important for Sou...

  19. The new international standard ISO 14001: 2004 environmental management system

    International Nuclear Information System (INIS)

    Oheba, Jamal Basher

    2006-01-01

    ISO 14001 is one standard in the ISO 14000 series of standards developed by International Organization of Standardization (ISO). Since it was published in 19096, it has rapidly become the most important environmental standard in the world. ISO 14001 is an environmental management system (EMS) that can be classified into environmental technologies provides a systematic procedure to all kind of organizations to prevent pollutions, protect environment and to improve their overall environmental performance. This new standard ISO 14001 2004 was published on November 15, 2004. It cancels and replaced the old ISO 14001-1996. Because the important of the previous standard for our local industries, firms, ...etc, this paper presents ISO 14001 concepts, issues, benefits and focuses on the stages of implementation to achieve ISO 14001-2004 certification which includes general requirements environmental policy, planning (objectives, targets ..), implementation and operations, checking and management review ...etc and presents how to apply isotop time saver software to design records, and to save time to implement ISO 14001 2004 and finally a conclusion is provided.(Author)

  20. The dark side of ISO 14001: The symbolic environmental behavior

    Directory of Open Access Journals (Sweden)

    Vera Ferrón Vílchez

    2017-01-01

    Full Text Available Some of the academic research on ISO 14001 has focused on analyzing the benefits of its adoption. However, this international standard has also received some criticism, particularly in respect of the adoption of ISO 14001 when not accompanied by significant improvements in environmental performance. This study analyzes the relationship between the symbolic environmental behavior and the adoption of ISO 14001. In so doing, it uses binary logistic regression to analyze an international sample of 1961 manufacturing facilities that each employs more than 50 people. The results indicate that the higher the symbolic environmental performance of the firm, the greater the probability of adopting ISO 14001.

  1. Risk in Management Systems according to ISO standard

    Directory of Open Access Journals (Sweden)

    P. Królas

    2010-07-01

    Full Text Available The purpose of this article was to present selected management standards in context of risk management. It presents main ISOmanagement standards (ISO 9001, ISO 14001, OHSAS 18001, ISO 27001, BS 25999, ISO 31000 that apply to polish enterprises. In thefirst part of this article there are analyzed management standards regarding quality, environment, occupational health and safety,information security, as well as business continuity management and risk management. The second part of the article discusses the processof dealing with risk based on chosen management standard.

  2. Measuring the Software Product Quality during the Software Development Life-Cycle: An ISO Standards Perspective

    OpenAIRE

    Rafa E. Al-Qutaish

    2009-01-01

    Problem statement: The International Organization for Standardization (ISO) published a set of international standards related to the software engineering, such as ISO 12207 and ISO 9126. However, there is a set of cross-references between the two standards. Approach: The ISO 9126 on software product quality and ISO 12207 on software life cycle processes had been analyzed to invistigate the relationships between them and to make a mapping from the ISO 9126 quality characteristics to the ISO 1...

  3. Twenty new ISO standards on dosimetry for radiation processing

    International Nuclear Information System (INIS)

    Farrar IV, H.

    2000-01-01

    Twenty standards on essentially all aspects of dosimetry for radiation processing were published as new ISO standards in December 1998. The standards are based on 20 standard practices and guides developed over the past 14 years by Subcommittee E10.01 of the American Society for Testing and Materials (ASTM). The transformation to ISO standards using the 'fast track' process under ISO Technical Committee 85 (ISO/TC85) commenced in 1995 and resulted in some overlap of technical information between three of the new standards and the existing ISO Standard 11137 Sterilization of health care products - Requirements for validation and routine control - Radiation sterilization. Although the technical information in these four standards was consistent, compromise wording in the scopes of the three new ISO standards to establish precedence for use were adopted. Two of the new ISO standards are specifically for food irradiation applications, but the majority apply to all forms of gamma, X-ray, and electron beam radiation processing, including dosimetry for sterilization of health care products and the radiation processing of fruit, vegetables, meats, spices, processed foods, plastics, inks, medical wastes, and paper. Most of the standards provide exact procedures for using individual dosimetry systems or for characterizing various types of irradiation facilities, but one covers the selection and calibration of dosimetry systems, and another covers the treatment of uncertainties using the new ISO Type A and Type B evaluations. Unfortunately, nine of the 20 standards just adopted by the ISO are not the most recent versions of these standards and are therefore already out of date. To help solve this problem, efforts are being made to develop procedures to coordinate the ASTM and ISO development and revision processes for these and future ASTM-originating dosimetry standards. In the meantime, an additional four dosimetry standards have recently been published by the ASTM but have

  4. Intermediate species measurement during iso-butanol auto-ignition

    KAUST Repository

    Ji, Weiqi

    2015-10-01

    © 2015 The Combustion Institute.Published by Elsevier Inc. All rights reserved. This work presents the time histories of intermediate species during the auto-ignition of iso-butanol at high pressure and intermediate temperature conditions obtained using a rapid compression machine and recently developed fast sampling system. Iso-butanol ignition delays were acquired for iso-butanol/O2 mixture with an inert/O2 ratio of 7.26, equivalence ratio of 0.4, in the temperature range of 840-950 K and at pressure of 25 bar. Fast sampling and gas chromatography were used to acquire and quantify the intermediate species during the ignition delay of the same mixture at P = 25.3 bar and T = 905 K. The ignition delay times and quantitative measurements of the mole fraction time histories of methane, ethene, propene, iso-butene, iso-butyraldehyde, iso-butanol, and carbon monoxide were compared with predictions from the detailed mechanisms developed by Sarathy et al., Merchant et al., and Cai et al. It is shown that while the Sarathy mechanism well predicts the overall ignition delay time, it overpredicts ethene by a factor of 6-10, underpredicts iso-butene by a factor of 2, and overpredicts iso-butyraldehyde by a factor of 2. Reaction path and sensitivity analyses were carried out to identify the reactions responsible for the observed inadequacy. The rates of iso-butanol hydrogen atom abstraction by OH radical and the beta-scission reactions of hydroxybutyl radicals were updated based on recently published quantum calculation results. Significant improvements were achieved in predicting ignition delay at high pressures (25 and 30 bar) and the species concentrations of ethene and iso-butene. However, the updated mechanism still overpredicts iso-butyraldehyde concentrations. Also, the updated mechanism degrades the prediction in ignition delay at lower pressure (15 bar) compared to the original mechanism developed by Sarathy et al.

  5. Intermediate species measurement during iso-butanol auto-ignition

    KAUST Repository

    Ji, Weiqi; Zhang, Peng; He, Tanjin; Wang, Zhi; Tao, Ling; He, Xin; Law, Chung K.

    2015-01-01

    © 2015 The Combustion Institute.Published by Elsevier Inc. All rights reserved. This work presents the time histories of intermediate species during the auto-ignition of iso-butanol at high pressure and intermediate temperature conditions obtained using a rapid compression machine and recently developed fast sampling system. Iso-butanol ignition delays were acquired for iso-butanol/O2 mixture with an inert/O2 ratio of 7.26, equivalence ratio of 0.4, in the temperature range of 840-950 K and at pressure of 25 bar. Fast sampling and gas chromatography were used to acquire and quantify the intermediate species during the ignition delay of the same mixture at P = 25.3 bar and T = 905 K. The ignition delay times and quantitative measurements of the mole fraction time histories of methane, ethene, propene, iso-butene, iso-butyraldehyde, iso-butanol, and carbon monoxide were compared with predictions from the detailed mechanisms developed by Sarathy et al., Merchant et al., and Cai et al. It is shown that while the Sarathy mechanism well predicts the overall ignition delay time, it overpredicts ethene by a factor of 6-10, underpredicts iso-butene by a factor of 2, and overpredicts iso-butyraldehyde by a factor of 2. Reaction path and sensitivity analyses were carried out to identify the reactions responsible for the observed inadequacy. The rates of iso-butanol hydrogen atom abstraction by OH radical and the beta-scission reactions of hydroxybutyl radicals were updated based on recently published quantum calculation results. Significant improvements were achieved in predicting ignition delay at high pressures (25 and 30 bar) and the species concentrations of ethene and iso-butene. However, the updated mechanism still overpredicts iso-butyraldehyde concentrations. Also, the updated mechanism degrades the prediction in ignition delay at lower pressure (15 bar) compared to the original mechanism developed by Sarathy et al.

  6. Manufacturing Bms/Iso System Review

    Science.gov (United States)

    Gomez, Yazmin

    2004-01-01

    The Quality Management System (QMS) is one that recognizes the need to continuously change and improve an organization s products and services as determined by system feedback, and corresponding management decisions. The purpose of a Quality Management System is to minimize quality variability of an organization's products and services. The optimal Quality Management System balances the need for an organization to maintain flexibility in the products and services it provides with the need for providing the appropriate level of discipline and control over the processes used to provide them. The goal of a Quality Management System is to ensure the quality of the products and services while consistently (through minimizing quality variability) meeting or exceeding customer expectations. The GRC Business Management System (BMS) is the foundation of the Center's ISO 9001:2000 registered quality system. ISO 9001 is a quality system model developed by the International Organization for Standardization. BMS supports and promote the Glenn Research Center Quality Policy and wants to ensure the customer satisfaction while also meeting quality standards. My assignment during this summer is to examine the manufacturing processes used to develop research hardware, which in most cases are one of a kind hardware, made with non conventional equipment and materials. During this process of observation I will make a determination, based on my observations of the hardware development processes the best way to meet customer requirements and at the same time achieve the GRC quality standards. The purpose of my task is to review the manufacturing processes identifying opportunities in which to optimize the efficiency of the processes and establish a plan for implementation and continuous improvement.

  7. [Construction of porous hydroxyapatite (HA) block loaded with cultured chondrocytes].

    Science.gov (United States)

    Yan, M; Dang, G

    1999-07-01

    To construct a kind of bone healing enhancing implant with cultured chondrocytes bound to hydroxyapatite (HA). Chondrocytes were obtained from the costicartilage of rat and were cultured on the porous HA blocks, 3 mm x 3 mm x 4 mm size, for three and seven days. Scanning electron micrograph was taken to show whether the cells grew outside and inside the pore of HA block. The cells cultured on tiny glass sheet for 2 days were used to prove where the cells come from by in situ hybridization technique with alpha1 (II) cDNA probe. Scanning electron micrographs showed that the pores of the HA surface and inside of the blocks are filled with cultured cells, especially the longer cultured block. The cells were chondrocytes confirmed by in situ hybridization. The porous HA can be used as cell cultured substrate and chondrocyte can adhere and proliferate inside the porous HA block.

  8. A Stepwise ISO-Based TQM Implementation Approach Using ISO 9001:2015

    Directory of Open Access Journals (Sweden)

    Chen Chi-kuang

    2016-12-01

    Full Text Available The lack of an implementation roadmap always deters enterprises from choosing Total Quality Management (TQM as its major management approach. This paper proposes a stepwise ISO-based TQM implementation approach which is based on the notion of the new three-dimensional overall business excellence framework developed by Dahlgaard et al. [1]. The proposed approach consists of nine steps comprising three categories: “TQM faith building”, “TQM tools and techniques learning”, and “system development”. The steps in each of the three categories are arranged to span across the proposed nine-step approach. The ISO 9001:2015 standard is used as a case study to demonstrate the proposed approach. The ideas and benefits of the proposed approach are further discussed in relation to this illustration.

  9. Effect of n-HA with different surface-modified on the properties of n-HA/PLGA composite

    Energy Technology Data Exchange (ETDEWEB)

    Jiang Liuyun, E-mail: jlytxg@163.com [Chengdu Institute of Organic Chemistry, Chinese Academy of Sciences, Chengdu 610041 (China); Xiong Chengdong; Chen Dongliang [Chengdu Institute of Organic Chemistry, Chinese Academy of Sciences, Chengdu 610041 (China); Jiang Lixin [Chengdu Institute of Organic Chemistry, Chinese Academy of Sciences, Chengdu 610041 (China); Graduated School of Chinese Academy of Sciences, Beijing 100039 (China); Pang Xiubing [Zhejiang Apeloa Medical Technology Co. Ltd, Jinhua 322118 (China)

    2012-10-15

    Graphical abstract: The bend strength of n-HA/PLGA composite with the unmodified n-HA becomes lower than that of PLGA. However, when n-HA was modified by different methods, the bend strength of g-n-HA/PLGA composites gets a little increase than PLGA, and the g3-n-HA/PLGA shows the highest bend strength at 3% g3-n-HA loading amount in weight, reached 162 MPa, which was 24.4% higher than that of pure PLGA. Highlights: Black-Right-Pointing-Pointer A new surface modification method for n-HA of combining stearic acid with surface-grafting L-lactic was adopted. Black-Right-Pointing-Pointer Three different surface modification methods for n-HA were compared in detail. Black-Right-Pointing-Pointer The new surface modification method was the most ideal method in this study. Black-Right-Pointing-Pointer The g3-n-HA/PLGA composite had the highest bending strength, which would be potential to be used as bone fracture internal fixation materials. - Abstract: Three different surface modification methods for nano-hydroxyapatite (n-HA) of stearic acid, grafted with L-lactide, combining stearic acid and surface-grafting L-lactic were adopted, respectively. The surface modification reaction and the effect of different methods were evaluated by Fourier transformation infrared (FTIR), X-ray photoelectron spectra (XPS), thermal gravimetric analysis (TGA), transmission electron microscopy (TEM). The results showed that n-HA surfaces were all successful modified, and the modification method of combining stearic acid and surface-grafting L-lactic had the greatest grafting amount and the best dispersion among the three modification methods. Then, the n-HA with three different surface modification and unmodified n-HA were introduced into PLGA, respectively, and a serials of n-HA/PLGA composites with 3% n-HA amount in weight were prepared by solution mixing, and the properties of n-HA/PLGA composites were also investigated by electromechanical universal tester and scanning electron

  10. Lessons learned with ISO 14001 at DOE sites

    Energy Technology Data Exchange (ETDEWEB)

    Wilkinson, C. H., LLNL

    1998-03-01

    ISO 14001 is the international standard for environmental management systems (EMS). The standard applies the `plan, do, check, act` management system model to assure that the environmental impacts of operations are fully considered in planning and facility operations. ISO 14001 has grown in popularity in both the public and the private sector and has seen increasing utility within the U.S. Department of Energy (DOE). While there is no final DOE policy or requirement for ISO 14001 EMS implementation, ISO 14001 commands an active presence at many DOE sites. In general, the impetus for ISO 14001 in the DOE complex has been either an initiative by site management contractors to improve performance, or an actual requirement in the new management contracts for the sites. Several DOE sites now are committed to implement EMS`s in conformance with ISO 14001: Brookhaven National Laboratory (BNL), Hanford, Idaho National Engineering and Environmental Laboratory (INEEL), Kansas City Plant, Nevada Test Site, Savannah River Site (SRS), Waste Isolation Pilot Project (WIPP), West Valley. Several other DOE sites are expected to proceed in the near future with an EMS consistent with ISO 14001. However, not all sites are proceeding with an ISO 14001 EMS based on individual site business considerations. This paper describes the status of EMS implementation at these sites and identifies lessons learned that may be of use to other DOE sites.

  11. Revision of the ISO and EN radiation sterilization standards

    DEFF Research Database (Denmark)

    Miller, A.; Hansen, J.

    2002-01-01

    The radiation sterilization standards, ISO 11137 and EN 552, are now being revised under "ISO lead", with the aim of producing only one international standard, although in four parts: (1) requirements. (2) dose-setting methods, (3) dose-substantiation methods and (4) dosimetry. Several aspects...

  12. ISO 9000 Series Certification Over Time: what have we learnt?

    NARCIS (Netherlands)

    A. van der Wiele (Ton); A.M. Brown (Alan)

    2002-01-01

    textabstractThe ISO 9000 experiences of the same sample of organisations over a five year time period is examined in this paper. The responses to a questionnaire sent out at the end of 1999 to companies which had a reasonably long term experience with the ISO 9000 series quality system are analysed.

  13. Evaluating Education Quality in Terms of ISO9000 Standards

    Science.gov (United States)

    Fengchun, Cheng; Vogel, Linda R.; Zhaoyu, Zheng

    2014-01-01

    While nations measure the quality of educational systems by different standards, many nations, such as China, have adopted the ISO9000 quality standards to assess the quality of schools. This article explores the various elements of the the ISO9000 standards and how each element relates to the various groups that are consumers or stakeholders in…

  14. Analysis of ISO 26262 Compliant Techniques for the Automotive Domain

    NARCIS (Netherlands)

    M. S. Kannan; Y. Dajsuren (Yanjindulam); Y. Luo; I. Barosan

    2015-01-01

    htmlabstractThe ISO 26262 standard denes functional safety for automotive E/E systems. Since the publication of the rst edition of this standard in 2011, many dierent safety techniques complying to the ISO 26262 have been developed. However, it is not clear which parts and (sub-) phases of the

  15. Analysis of ISO 26262 compliant techniques for the automotive domain

    NARCIS (Netherlands)

    S., Manoj Kannan; Dajsuren, Y.; Luo, Y.; Barosan, I.; Antkiewicz, M.; Atlee, J.; Dingel, J.; S, R.

    2015-01-01

    The ISO 26262 standard defines functional safety for automotive E/E systems. Since the publication of the first edition of this standard in 2011, many different safety techniques complying to the ISO 26262 have been developed. However, it is not clear which parts and (sub-) phases of the standard

  16. ISO 14001 ENVIRONMENTL MANAGEMENT SYSTEMS IN GOVERNMENT AND INDUSTRY

    Science.gov (United States)

    Two new USEPA documents address environmental management systems (EMS) from the perspectives of government and industry and are offered as tools for understanding the process of the ISO 14000 Standards development and usefulness of an EMS approach. The first document, ISO 14001 -...

  17. Usability evaluation of mobile applications using ISO 9241 and ISO 25062 standards.

    Science.gov (United States)

    Moumane, Karima; Idri, Ali; Abran, Alain

    2016-01-01

    This paper presents an empirical study based on a set of measures to evaluate the usability of mobile applications running on different mobile operating systems, including Android, iOS and Symbian. The aim is to evaluate empirically a framework that we have developed on the use of the Software Quality Standard ISO 9126 in mobile environments, especially the usability characteristic. To do that, 32 users had participated in the experiment and we have used ISO 25062 and ISO 9241 standards for objective measures by working with two widely used mobile applications: Google Apps and Google Maps. The QUIS 7.0 questionnaire have been used to collect measures assessing the users' level of satisfaction when using these two mobile applications. By analyzing the results we highlighted a set of mobile usability issues that are related to the hardware as well as to the software and that need to be taken into account by designers and developers in order to improve the usability of mobile applications.

  18. Standardization of Image Quality Analysis – ISO 19264

    DEFF Research Database (Denmark)

    Wüller, Dietmar; Kejser, Ulla Bøgvad

    2016-01-01

    There are a variety of image quality analysis tools available for the archiving world, which are based on different test charts and analysis algorithms. ISO has formed a working group in 2012 to harmonize these approaches and create a standard way of analyzing the image quality for archiving...... systems. This has resulted in three documents that have been or are going to be published soon. ISO 19262 defines the terms used in the area of image capture to unify the language. ISO 19263 describes the workflow issues and provides detailed information on how the measurements are done. Last...... but not least ISO 19264 describes the measurements in detail and provides aims and tolerance levels for the different aspects. This paper will present the new ISO 19264 technical specification to analyze image quality based on a single capture of a multi-pattern test chart, and discuss the reasoning behind its...

  19. ISO 9001 in a neonatal intensive care unit (NICU).

    Science.gov (United States)

    Vitner, Gad; Nadir, Erez; Feldman, Michael; Yurman, Shmuel

    2011-01-01

    The aim of this paper is to present the process for approving and certifying a neonatal intensive care unit to ISO 9001 standards. The process started with the department head's decision to improve services quality before deciding to achieve ISO 9001 certification. Department processes were mapped and quality management mechanisms were developed. Process control and performance measurements were defined and implemented to monitor the daily work. A service satisfaction review was conducted to get feedback from families. In total, 28 processes and related work instructions were defined. Process yields showed service improvements. Family satisfaction improved. The paper is based on preparing only one neonatal intensive care unit to the ISO 9001 standard. The case study should act as an incentive for hospital managers aiming to improve service quality based on the ISO 9001 standard. ISO 9001 is becoming a recommended tool to improve clinical service quality.

  20. Improving Earth Science Metadata: Modernizing ncISO

    Science.gov (United States)

    O'Brien, K.; Schweitzer, R.; Neufeld, D.; Burger, E. F.; Signell, R. P.; Arms, S. C.; Wilcox, K.

    2016-12-01

    ncISO is a package of tools developed at NOAA's National Center for Environmental Information (NCEI) that facilitates the generation of ISO 19115-2 metadata from NetCDF data sources. The tool currently exists in two iterations: a command line utility and a web-accessible service within the THREDDS Data Server (TDS). Several projects, including NOAA's Unified Access Framework (UAF), depend upon ncISO to generate the ISO-compliant metadata from their data holdings and use the resulting information to populate discovery tools such as NCEI's ESRI Geoportal and NOAA's data.noaa.gov CKAN system. In addition to generating ISO 19115-2 metadata, the tool calculates a rubric score based on how well the dataset follows the Attribute Conventions for Dataset Discovery (ACDD). The result of this rubric calculation, along with information about what has been included and what is missing is displayed in an HTML document generated by the ncISO software package. Recently ncISO has fallen behind in terms of supporting updates to conventions such updates to the ACDD. With the blessing of the original programmer, NOAA's UAF has been working to modernize the ncISO software base. In addition to upgrading ncISO to utilize version1.3 of the ACDD, we have been working with partners at Unidata and IOOS to unify the tool's code base. In essence, we are merging the command line capabilities into the same software that will now be used by the TDS service, allowing easier updates when conventions such as ACDD are updated in the future. In this presentation, we will discuss the work the UAF project has done to support updated conventions within ncISO, as well as describe how the updated tool is helping to improve metadata throughout the earth and ocean sciences.

  1. ISO Spectroscopy of Proto-Planetary Nebulae

    Science.gov (United States)

    Hrivnak, Bruce J.

    2000-01-01

    The goal of this program was to determine the chemical properties of the dust shells around protoplanetary nebulae (PPNs) through a study of their short-wavelength (6-45 micron) infrared spectra. PPNs are evolved stars in transition from the asymptotic giant branch to the planetary nebula stages. Spectral features in the 10 to 20 gm region indicate the chemical nature (oxygen- or carbon-rich), and the strengths of the features relate to the physical properties of the shells. A few bright carbon-rich PPNs have been observed to show PAH features and an unidentified 21 micron emission feature. We used the Infrared Space Observatory (ISO) to observe a sample of IRAS sources that have the expected properties of PPNs and for which we have accurate positions. Some of these have optical counterparts (proposal SWSPPN01) and some do not (SWSPPN02). We had previously observed these from the ground with near-infrared photometry and, for those with visible counterparts, visible photometry and spectroscopy, which we have combined with these new ISO data in the interpretation of the spectra. We have completed a study of the unidentified emission feature at 21 micron in eight sources. We find the shape of the feature to be the same in all of the sources, with no evidence of any substructure. The ratio of the emission peak to continuum ranges from 0.13 to 1.30. We have completed a study of seven PPNs and two other carbon-rich objects for which we had obtained ISO 2-45 micron observations. The unidentified emission features at 21 and 30 micron were detected in six sources, including four new detections of the 30 micron feature. This previously unresolved 30 micron feature was resolved and found to consist of a broad feature peaking at 27.2 micron (the "30 micron" feature) and a narrower feature peaking at 25.5 micron (the "26 micron" feature). This new 26 micron feature is detected in eight sources and is particularly strong in IRAS Z02229+6208 and 16594-4656. The unidentified

  2. Sertifikatõ ISO - mafioznaja struktura so znakom pljuss / Olesja Bõkova

    Index Scriptorium Estoniae

    Bõkova, Olesja

    2005-01-01

    Esimesed ISO sertifikaadid, mille aluseks on briti kvaliteedi standardite süsteem, anti Euroopa Liidus välja 1987. a. ISO sertifikaadid Eestis. Diagramm: Välja antud ISO 9000 sertifikaadid 1994-2004

  3. Võidupüha 8. mail? / Leonti Kährik

    Index Scriptorium Estoniae

    Kährik, Leonti

    2005-01-01

    Eesti peaks väärikalt tähistama võidupüha kui euroopalike demokraatlike väärtuste võitu natsismi ja fašismi üle. Lähtudes 1940. a. juunini Eestis kehtinud vööndiajast, võiks võidupüha tähistada 8. mail

  4. L'ús de la norma de qualitat ISO 9001 a les biblioteques d'institucions d'educació superior = El uso de la norma de calidad ISO 9001 en las bibliotecas de instituciones de educación superior

    OpenAIRE

    Balagué, Núria; ,

    2007-01-01

    La norma ISO 9001 és un dels instruments de gestió que han estat adoptats per les biblioteques durant els darrers anys. En aquest article es presenten els trets principals de les biblioteques d'institucions d'ensenyament superior que han assolit la certificació dels seus sistemes de gestió de la qualitat amb la norma ISO 9001:2000, els motius que les han dut a certificar-se, i els avantatges i les dificultats que els ha comportat aplicar-la. Finalment, s'ofereix una visió prospectiva sobre el...

  5. The stability of iso-α-acids and reduced iso-α-acids in stored blood specimens.

    Science.gov (United States)

    Rodda, Luke N; Gerostamoulos, Dimitri; Drummer, Olaf H

    2014-06-01

    The long-term stability of the iso-α-acids, and three structurally similar but chemically altered iso-α-acids (known as 'reduced iso-α-acids' and consisting of the rho-, tetrahydro- and hexahydro-iso-α-acid groups) were investigated in whole blood. Pools of blank blood spiked with the four beer-specific ingredient congener groups at two different concentration levels were stored at 20°C, 4°C and -20°C; and extracted in duplicate in weeks 1, 3, 5 and 8, using a previously published method. A loss of 15% of the initial concentration was considered to indicate possible instability and losses greater than 30% demonstrated significant losses. The individual analytes within the four iso-α-acid groups were also measured to determine which iso-α-acids were subject to greater degradation and were responsible for the overall group instability. All four iso-α-acid groups showed significant losses after 8 weeks of storage under room temperature conditions in particularly the natural iso-α-acid group where major losses were observed (96% and 85% losses for low and high concentrations, respectively). Some degradation in all iso-α-acid groups were seen at 4°C samples predominantly due to the 'n' analogs of the groups showing an increased instability in blood. The -20°C storage conditions resulted in minimal changes in concentrations of all analytes. Higher than frozen storage temperatures can result in substantial changes on the stability of the iso-α-acid type groups in blood. The aim of this study was to highlight the stabilities of the IAA analytes in order to assist in the interpretation of IAA in stored blood specimens. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  6. Impacto de la certificación ISO 9001 en clínicas de Cali, Colombia

    Directory of Open Access Journals (Sweden)

    Juan Carlos Osorio Gómez

    2015-12-01

    Full Text Available El auge de la certificación ISO 9001 ha hecho que no solo las empresas manufactureras, sino también las organizaciones prestadoras de servicios, entren en estos procesos de certificación. Sin embargo, permanece latente la pregunta sobre si efectivamente la organización obtiene un beneficio real por implementar y certificar su sistema de gestión de la calidad según dicha norma. Por eso se ha desarrollado el presente proyecto de investigación, en el que se ha buscado medir el impacto de la certificación ISO 9001 en las clínicas de la ciudad de Cali, en Colombia, enfocándose principalmente en los aspectos de calidad y competitividad de estas compañías. Para ello, se contactaron las clínicas certificadas en la ciudad y, mediante información directa suministrada por las entidades, se logró determinar el grado de impacto alcanzado por estas en los aspectos mencionados. Es importante destacar que todas las clínicas participantes del proceso han obtenido un impacto positivo en sus indicadores a partir de la certificación. Los indicadores definidos y los instrumentos utilizados para este proyecto pueden ser fácilmente ajustados para el mismo propósito en otros sectores y en cualquier tipo de organizaciones.

  7. Preparation of bioactive porous HA/PCL composite scaffolds

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, J.; Guo, L.Y.; Yang, X.B. [Key Laboratory of Advanced Technologies of Materials (Ministry of Education), School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031 (China); Weng, J. [Key Laboratory of Advanced Technologies of Materials (Ministry of Education), School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031 (China)], E-mail: jweng@swjtu.cn

    2008-12-30

    Porous hydroxyapatite (HA) bioceramic scaffold has been widely attracted the attention to act as a three-dimensional (3D) template for cell adhesion, proliferation, differentiation and thus promoting bone and cartilage regeneration because of its osteoinduction. However, the porous bioceramic scaffold is fragile so that it is not suitable to be applied in clinic for bone repair or replacement. Therefore, it is significant to improve the mechanical property of porous HA bioceramics while the interconnected structure is maintained for tissue ingrowth in vivo. In the present research, a porous composite scaffold composed of HA scaffold and polycaprolactone (PCL) lining was fabricated by the method of polymer impregnating to produce HA scaffold coated with PCL lining. Subsequently, the composite scaffolds were deposited with biomimetic coating for improving the bioactivity. The HA/PCL composite scaffolds with improved mechanical property and bioactivity is expected to be a promising bone substitute in tissue engineering applications.

  8. Preparation of bioactive porous HA/PCL composite scaffolds

    International Nuclear Information System (INIS)

    Zhao, J.; Guo, L.Y.; Yang, X.B.; Weng, J.

    2008-01-01

    Porous hydroxyapatite (HA) bioceramic scaffold has been widely attracted the attention to act as a three-dimensional (3D) template for cell adhesion, proliferation, differentiation and thus promoting bone and cartilage regeneration because of its osteoinduction. However, the porous bioceramic scaffold is fragile so that it is not suitable to be applied in clinic for bone repair or replacement. Therefore, it is significant to improve the mechanical property of porous HA bioceramics while the interconnected structure is maintained for tissue ingrowth in vivo. In the present research, a porous composite scaffold composed of HA scaffold and polycaprolactone (PCL) lining was fabricated by the method of polymer impregnating to produce HA scaffold coated with PCL lining. Subsequently, the composite scaffolds were deposited with biomimetic coating for improving the bioactivity. The HA/PCL composite scaffolds with improved mechanical property and bioactivity is expected to be a promising bone substitute in tissue engineering applications

  9. Electrospun Porous PDLLA Fiber Membrane Coated with nHA

    Directory of Open Access Journals (Sweden)

    Linhui Qiang

    2018-05-01

    Full Text Available Porous poly- D, L-lactic acid (PDLLA electrospinning fiber membrane was prepared, and nano-hydroxyapatite (nHA was adsorbed and wrapped into it during the unique shrinking process of the PDLLA fiber membrane to fabricate the PDLLA/nHA composite membrane scaffold for tissue engineering. Compare with the composite fibers prepared by blend electrospinning, most of nHA particles are observed to distribute on the surface of new type composite fibers, which could significantly improve the water wettability and induce the cellular adherence. FTIR analysis indicated that the PDLLA/nHA composite fibrous membrane was formed by physical adsorption. The combination was probed by scanning electron microscope, thermo-gravimetric, water contact angle and mechanical property analysis. It was proved that the nHA particles’ content and distribution, surface wettability, modulus and tensile strength of PDLLA/nHA composite fibrous membrane were influenced by the concentration of nHA dispersion and pores on the PDLLA fiber surface. The 10.6 wt % PDLLA/nHA composite fibrous membrane exhibits a more balanced tensile strength (3.28 MPa and surface wettability (with a water contact angle of 0° of the composite mats. Scanning electron microscope and confocal laser scanning microscopy images of chondrocyte proliferation further showed that the composite scaffold is non-toxic. The adherence and proliferation of chondrocytes on the 10.6 wt % PDLLA/nHA fibrous membrane was significantly improved, compared with PDLLA mat. The 10.6 wt % PDLLA/nHA composite fibrous membrane has potential application value as scaffold material in tissue engineering.

  10. ADOPTION OF ISO 9001 QUALITY MANAGEMENT STANDARD IN AFRICA

    Directory of Open Access Journals (Sweden)

    Erlantz Allur

    2014-03-01

    Full Text Available This article analyzes the dissemination of ISO 9001, the main global management standards, within Africa. The work refers to the diffusion of ISO 9001 standard in terms of its certification intensity. In this article, the dissemination of ISO 9001 in Africa has been analyzed. The findings reveal that the diffusion of the standard in this continent is not very relevant, what might be seen as an indicator of the process of Africa's trade marginalization in the age of globalization. The general certification intensity of the continet is of 0.18; in other words, the proportion of the contribution of Africa to the global GDP of the world is more than five times superior to the proportion of ISO 9001 certificates located in Africa. By means of the logistic model the dissemination of ISO 9001 is forecasted, and it has been observed that the diffusion of ISO 9001 in Africa is in an 85% of its saturation point. Taking into account this model, it's expected that the dissemination of ISO 9001 will be growing until 2020.

  11. Complexing properties of α-iso-saccharinate: thorium

    International Nuclear Information System (INIS)

    Allard, S.; Ekberg, C.

    2005-01-01

    Full text of publication follows: In the alkaline conditions of the intended Swedish repository for long-lived, low to intermediate level waste, SFL3-5, cellulose based items will degrade with iso-saccharinate being the dominant end-product. Iso-saccharinate is a strong complexing agent for tetravalent actinides, as well as for trivalent lanthanides, and its complexation properties are of interest for the long-term repository assessment. In the presented study, the complexation of 234 Th-α-iso-saccharinate is examined using liquid-liquid- extraction and radioanalytical techniques. An organic phase consisting of 0.1 M acetylacetone in toluene was used with a 1.0 M NaClO 4 aqueous phase kept at pH 8 in a thermostated AKUFVE unit. Since the α-iso-saccharinic system consists of three species - the carboxylic α-iso-saccharinic acid, α-iso-saccharinate and α-D-iso-saccharino-1,4-lactone - care must be taken when choosing the operational pH. Keeping the aqueous phase at pH 8 results in negligible concentrations of all but the α-iso-saccharinate form while at the same time being an excellent pH for the 234 Th-acetylacetone complexation with very limited hydrolysis effect. The α- iso-saccharinate concentration was incrementally increased, and samples of equal volumes were taken from the two phases and analyzed in a liquid scintillation detector once the radioactive equilibrium between 234 Th and 234 Pa had been reached. Two complexation constants were used to fit a distribution equation to the experimental data. (authors)

  12. ISO 26000 – An Integrative Approach of Corporate Social Responsibility

    Directory of Open Access Journals (Sweden)

    Herciu Mihaela

    2016-04-01

    Full Text Available ISO 26000 represents a guidance on corporate social responsibility and it is, at the present time, one of the most important document on CSR in the world. Without being mandatory or regulated, ISO 26000 is focus on seven core subjects that have to be approached synergistic – governance, human right, labor, environment, business practices, consumer, and community – in order to achieve its goal. The present paper intends to present and analyze the seven core subjects of ISO 26000 from tow perspectives: by emphasizing the benefits of implementing the standard into the business strategy and by revealing the correlation between corporate social responsibility and sustainable development.

  13. [ISO 9001:2015 Certification in Quality Management].

    Science.gov (United States)

    Enders, Christian; Lang, Gabriele E; Lang, Gerhard K; Werner, Jens Ulrich

    2017-07-01

    Quality management improves the structures, processes and results of organizations of all kinds. Many practices and clinics have their existing quality management system certified according to ISO 9001, (e.g., to check their own quality management system or to obtain a testimonial against third parties). The latest version ISO 9001:2015 contains some changes, both structurally and in terms of content. These changes can be met with reasonable efforts. An ISO 9001:2015 certification represents a value for your organization, but these advantages are often not directly measurable. Georg Thieme Verlag KG Stuttgart · New York.

  14. Information security in accordance with ISO/IEC 27000

    OpenAIRE

    Košćak , Damjan

    2011-01-01

    The diploma assignment discusses Information Technology Security according to standards ISO/IEC 27001 and ISO/IEC 27002. Diploma consists of two parts. In the first part of the diploma a theoretical bases of information security are presented. The second part presents the introduction of ISO/IEC 27001 security standard in the company »X« in wich I performed a practical training. In the closure my diploma work is upgraded with results of my research work and their analysis as well as wit...

  15. Bahan pemutih gigi dengan sertifikat ADA/ISO (Tooth bleaching material with ADA/ISO certificate

    Directory of Open Access Journals (Sweden)

    Asti Meizarini

    2005-06-01

    Full Text Available Bleaching of teeth for cosmetic reasons is a popular aspect of cosmetic dentistry because patients realize the aesthetical benefits of these products. The dentist as a clinician's practitioner must be knowledgeable of the products and their application techniques. Bleaching materials which are safe and effective are the ADA accepted or manufactured by those which have already haved ISO certificate. Dentist must have enough knowledge about in-office bleaching prescribed for home-use bleaching including their contra indication and side effects, to advise the patients and provide effective bleaching services.

  16. Design and fabrication of carbon fibers with needle-like nano-HA coating to reinforce granular nano-HA composites.

    Science.gov (United States)

    Wang, Xudong; Zhao, Xueni; Zhang, Li; Wang, Wanying; Zhang, Jing; He, Fuzhen; Yang, Jianjun

    2017-08-01

    Carbon fibers (CFs) with needle-like nano-hydroxyapatite (nHA) coating were first used as reinforcing materials named nHA-CFs to improve the mechanical properties of pure HA. A powder mixture containing nHA-CFs and granular nano-HA (gHA) was directly sintered by hot pressing at appropriate sintering pressure and temperature. A three-phase nHA-CFs/gHA composite was designed, fabricated, and used as an artificial bone. Results show that the bending strengths of the nHA-CFs/gHA composite are approximately 41.1% and 59.2% higher than those of CFs/gHA composite and pure HA, respectively. The possible reinforcing mechanism of nHA-CFs in the composite is also proposed at the end. When nHA-CFs are applied for preparation of nHA-CFs/gHA composites, the internal stress on its phase boundary with gHA matrix generated during cooling of sintered is significantly reduced due to the presence of the nHA coatings. It infers that nHA coatings on CFs might act as a bridge to control the forming of interfacial gaps between the gHA matrix and the CFs effectively. Our work provides additional insights into the feasibility of nHA-CFs/gHA composites as load-bearing implant materials in clinical applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Exploration of underground basement structures in Kanto plain using the spatial autocorrelation method. 1. S-wave velocity structure along the line from Hatoyama, Saitama to Noda, Chiba; Kukan jiko sokanho ni yoru Kanto heiya no kiban kozo tansa. 1. Saitamaken Hatoyama machi - Chibaken Nodashi kan no S ha sokudo kozo

    Energy Technology Data Exchange (ETDEWEB)

    Matsuoka, T; Umezawa, N; Shiraishi, H [Saitama Institute of Environmental Pollution, Saitama (Japan)

    1997-05-27

    The Saitama prefectural government has been conducting basement structure exploration using the spatial autocorrelation method by dividing the entire plain area into meshes, for the purpose of improving the accuracy of estimating large-scale seismic damages. This paper reports the result of explorations on meshes in the east-west direction in the central part of Saitama Prefecture. The present exploration was intended on ten meshes in the east-west direction along the north latitude 36-degree line. The number of exploration points is 13 comprising three points on the hilly area bordering on the eastern edge of the Kanto mountainous area and ten points on the plain area. The arrangement constitutes a traverse line with a total distance of about 33 km from the west edge (Hatoyama-machi in Saitama Prefecture) to the east edge (Noda City in Chiba Prefecture). The phase velocities were estimated from the result of the array microtremor observations using the spatial autocorrelation method applied with the FET. The phase velocities were used to estimate underground structures by using an inverse analysis. As a result, detailed two-dimensional S-wave velocity structures were revealed on the traverse line. The velocity cross section expresses change in the basement structures with sufficient resolution, and at the same time the information is judged highly harmonious with existing deep boring data and the result of artificial earthquake exploration. 15 refs., 6 figs.

  18. ITIL and ISO/IEC 20000 a practical handbook

    CERN Document Server

    Hernandez, Alex

    2012-01-01

    The purpose of this publication is to provide your organization with a pragmatic approach to effectively implementing service management, incorporating practices from the ITIL framework and the ISO/IEC 20000 standard.

  19. Standardization by ISO to Ensure the Sustainability of Space Activities

    Science.gov (United States)

    Kato, A.; Lazare, B.; Oltrogge, D.; Stokes, H.

    2013-08-01

    The ISO / Technical Committee 20 / Sub-committee 14 develops debris-related standards and technical reports to mitigate debris and help ensure mission and space sustainability. While UN Guidelines and the IADC Guidelines encourage national governments and agencies to promote debris mitigation design and operation, the ISO standards will help the global space industry promote and sustain its space-related business. In this paper the scope and status of each ISO standard is discussed within an overall framework. A comparison with international guidelines is also provided to demonstrate the level of consistency. Finally, as a case study, the ISO standards are applied to a CubeSat mission, thus demonstrating their usability on a relatively recent and popular class of satellite.

  20. Applicability of ISO 16697 Data to Spacecraft Fire Fighting Strategies

    Science.gov (United States)

    Hirsch, David B.; Beeson, Harold D.

    2012-01-01

    Presentation Agenda: (1) Selected variables affecting oxygen consumption during spacecraft fires, (2) General overview of ISO 16697, (3) Estimated amounts of material consumed during combustion in typical ISS enclosures, (4) Discussion on potential applications.

  1. CNEN, IAEA and ISO normative requirements for measurement management

    International Nuclear Information System (INIS)

    Kibrit, Eduardo

    2009-01-01

    International standard ISO 10012:2003 establishes requirements for measurement management systems, including requirements for measurement processes and measuring equipment. ISO 9001:2008 presents requirements for quality management systems, including requirements for the control of monitoring and measuring equipment. ISO 17025:2005 presents general requirements for the competence of testing and calibration laboratories. In the nuclear field the requirements for measurement management are established by standards published by the International Atomic Energy Agency (IAEA), and in Brazil, by the National Nuclear Energy Commission (CNEN). The present paper presents and discusses the normative requirements for measurement management, considering requirements established by National Nuclear Energy Commission (CNEN), International Atomic Energy Agency (IAEA), and International Organisation for Standardisation (ISO). (author)

  2. [Accreditation of clinical laboratories based on ISO standards].

    Science.gov (United States)

    Kawai, Tadashi

    2004-11-01

    International Organization for Standardization (ISO) have published two international standards (IS) to be used for accreditation of clinical laboratories; ISO/IEC 17025:1999 and ISO 15189:2003. Any laboratory accreditation body must satisfy the requirements stated in ISO/IEC Guide 58. In order to maintain the quality of the laboratory accreditation bodies worldwide, the International Laboratory Accreditation Cooperation (ILAC) has established the mutual recognition arrangement (MRA). In Japan, the International Accreditation Japan (IAJapan) and the Japan Accreditation Board for Conformity Assessment (JAB) are the members of the ILAC/MRA group. In 2003, the Japanese Committee for Clinical Laboratory Standards (JCCLS) and the JAB have established the Development Committee of Clinical Laboratory Accreditation Program (CLAP), in order to establish the CLAP, probably starting in 2005.

  3. ISO 9000. Guidelines to increased costs and reduced product quality

    International Nuclear Information System (INIS)

    Reedy, R.F.

    1994-01-01

    Many US companies are considering being registered to the provisions of ISO 9000, International Standards for Quality Management. One important problem with the document is that ISO 9000 is not focused on control of product quality. The quality assurance rules established in ISO 9000 have been used in the US for more than 25 years with disastrous financial consequences and little, if any, improvement in quality and safety. These rules are so reliant on documentation and strict compliance that ensuring products comply with specifications has become a secondary issues. That is not what was intended, but it is the result. ISO 9000 program can work effectively only when the top executive responsible for engineering or production takes full responsibility for interpretation and implementation of the quality assurance program. 3 refs., 1 tab

  4. ISO and EIGA standards for cryogenic vessels and accessories

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    The EIGA/WG 6’s scope is cryogenic vessels and accessories, including their design, material compatibility, operational requirements and periodical inspection. The specific responsibilities include monitoring international standardization (ISO, CEN) and regulations (UN, TPED, PED...

  5. Experience with ISO quality control in assisted reproductive technology.

    Science.gov (United States)

    Alper, Michael M

    2013-12-01

    Assisted reproductive technology (ART) programs are complex organizations requiring the integration of multiple disciplines. ISO 9001:2008 is a quality management system that is readily adaptable to an ART program. The value that ISO brings to the entire organization includes control of documents, clear delineation of responsibilities of staff members, documentation of the numerous processes and procedures, improvement in tracking and reducing errors, and overall better control of systems. A quality ART program sets quality objectives and monitors their progress. ISO provides a sense of transparency within the organization and clearer understanding of how service is provided to patients. Most importantly, ISO provides the framework to allow for continual improvement. Copyright © 2013 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  6. Isoe - information system on occupational exposure. Ten years of experience

    International Nuclear Information System (INIS)

    2002-01-01

    The information System on Occupational Exposure (ISOE) was created in 1992 to provide a forum for radiation protection experts from both utilities and national regulatory authorities to discuss, promote and co-ordinate international co-operative undertakings in the area of worker protection at nuclear power plants. The ISOE System is jointly managed by the OECD Nuclear Energy Agency (NEA) and the International Atomic Energy Agency (IAEA). This report provides an overview of the experience gained from, and benefits provided by, the ISOE System over the past ten years. Active participation of a large number of utilities in ISOE has contributed to a reduction in occupational exposure at nuclear power plants worldwide. (authors)

  7. Incorporating an ISO 8583-Service into an Unreliable Application

    OpenAIRE

    Funcke, Alexander

    2008-01-01

    If an existing service is to be made available to a broader audience, via for instance the Internet. The implementation of the service may thereby get many new requirements, such as support for a different access method or stricter authorisation and security policies. This thesis discusses the implementation of an ISO 8583 to XML proxy. ISO 8583 is a widely used financial protocol, and was in this project used to communicate with the backing financial server in order to implement a complete w...

  8. A-Ha. Drum'n'bassi supernimi FABIO

    Index Scriptorium Estoniae

    2002-01-01

    7.sept. annab norra menukaim popansambel A-Ha Tallinnas Lauluväljakul kontserdi, kus presenteerib ka oma viimast albumit "Lifelines". 14. sept.tuleb drum'n'bassi spetsialist Fabio Tallinna üritusele Circulation

  9. Adhesive strength of hydroxyl apatite(HA coating and biomechanics behavior of HA-coated prosthesis:an experimental study

    Directory of Open Access Journals (Sweden)

    Tian-yang ZHANG

    2011-05-01

    Full Text Available Objective To explore the influence of adhesive strength of hydroxyapatite(HA coating on the post-implantation stability of HA-coated prosthesis.Methods The adhesive strength and biomechanics behavior of HA coating were studied by histopathological observation,material parameters and biomechanical testing,the titanium(Ti-coated prosthesis was employed as control.Results Scratch test showed that the adhesive strength of HA coating was significantly lower than that of Ti coating(P < 0.01.Histopathological examination and bone morphometry showed that,at the early stage of prosthesis implantation,the bony growth around HA-coated prosthesis was significantly higher than that around Ti-coated prosthesis(P < 0.01,but the ultimate shear strength of HA-coated prosthesis was much lower than that of Ti-coated prosthesis(P < 0.01.After the push-out test with prosthesis,histopathological observation showed that there were accumulations of clump-and strip-like granular residues on the surface of bones that newly grew around the HA-coated prosthesis,and surface energy-dispersive X-ray spectroscopy(EDX analysis also confirmed that the shear stress induced HA decohesion from the substrate of prosthesis.Conclusions Although HA coating showed a satisfactory effect on early bone formation and prosthetic stability,due to the deficiencies of adhesive strength,the early stability of prosthesis may be gradually destroyed by the shear loads of human body and coating degradation.

  10. Inter ISO Market Coordination by Calculating Border Locational Marginal Prices

    Directory of Open Access Journals (Sweden)

    BABIC, A. B.

    2013-05-01

    Full Text Available In this paper the methodology for solving Locational Marginal Price (LMP differences (inconsistency of LMPs that arise at the boundary buses between separate power markets is proposed. The algorithm developed enables us to obtain consistent LMP values at the boundary buses between interconnected ISOs. A Primal-Dual Interior Point based optimal power flow (OPF is applied, with complete set of power system physical limit constraints, to solve a regional spot market. The OPF is implemented such that producer and consumer behaviors are modeled simultaneously, while the welfare is maximized. In this paper a generalized methodology for multiple ISOs case is proposed and later it is practically applied on two interconnected independent entities. The algorithm for approximation of cost coefficients of generators and dispatchable loads for neighboring ISOs is proposed. The developed algorithm enables participating ISOs to obtain LMPs at the boundary buses with other interconnected ISOs. By controlling interchange of electric power at the scheduled level, regional spot markets are resolved eliminating possible exercise of market power by individual interconnected ISOs. Results of proposed methodology are tested on the IEEE 118-bus power system.

  11. The impact of ISO 14000 on developing world businesses

    International Nuclear Information System (INIS)

    Mohamed, S.T.

    2001-01-01

    ISO 14000 has attracted interest from industry, international organizations and governments around the globe. Policy-makers and industry both appear to be looking to the standards as a key component of a new paradigm for cooperation between regulators and industry. This realization seems to have resulted from a growing awareness that the fragmented, reactive approach to environmental management in the past has not produced optimal results. Businesses are realizing the value of integrating their compliance procedures for each regulation into a broader system. Compliance problems can often be linked to system problems such as inadequate training, lack of responsibility at the right level, inadequate data, and other related causes. An effective Environmental Management System (EMS) eliminates these pitfalls. The evolution of the EMS is being shaped by market forces, ISO 9000, regulatory shifts, public awareness, and cost implications for ISO certifications. The transformation of these management practices is not limited to industrialized countries. In anticipation of the non-tariff trade barriers that could be erected as a result of these standards, many developing countries are seeking avenues of compliance with ISO 14000's requirements. Egypt should be concerned with the implementation of this system, for firms in countries of the European Community (EC) have been given explicit instructions by the three prevalent European standard-setting organizations to ''familiarize'' themselves with the requirements of ISO 14000. This paper will focus primarily on the expected effects of ISO 14001. (author)

  12. Verification the 25-kgy dose using the iso standard iso/tr 13409 for the production of bone grafts

    International Nuclear Information System (INIS)

    Otero, I.; Barrera, L.; Diaz, A.; Napoles, D.; Sanchez, E

    2001-01-01

    The purpose of this work was to verify the 25 Gy dose using the ISO standard ISO/TR 13409 for the production of bone grafts from the Tissue Bank ORTOP of the Complejo Cientifico Ortopedico Internacional Frank Pais. We performed two principal microbiological activities: bioburden estimate, pre-sterilization count plus a compensation for the efficiency of the recovery method, by ISO 11737-1 and test of sterility by ISO 11737-2. The techniques for Bioburden estimation could be direct or indirect. Choice of direct vs. indirect depends on number of contaminating micro-organisms, product configuration, ability to remove microbial contamination, effect of removal method on microbial viability, types and location of micro-organisms, nature of product and culture conditions. For a test of sterility, he product unit or SIP putted direct immersion in educated culture medium and incubate. Keep precaution to minimize level to the false positives is necessary

  13. Osteoblast interaction with laser cladded HA and SiO2-HA coatings on Ti-6Al-4V

    International Nuclear Information System (INIS)

    Yang Yuling; Serpersu, Kaan; He Wei; Paital, Sameer R.; Dahotre, Narendra B.

    2011-01-01

    In order to improve the bioactivity and biocompatibility of titanium endosseous implants, the morphology and composition of the surfaces were modified. Polished Ti-6Al-4V substrates were coated by a laser cladding process with different precursors: 100 wt.% HA and 25 wt.% SiO 2 -HA. X-ray diffraction of the laser processed samples showed the presence of CaTiO 3 , Ca 3 (PO 4 ) 2 , and Ca 2 SiO 4 phases within the coatings. From in vitro studies, it was observed that compared to the unmodified substrate all laser cladded samples presented improved cellular interactions and bioactivity. The samples processed with 25 wt.% SiO 2 -HA precursor showed a significantly higher HA precipitation after immersion in simulated body fluid than 100 wt.% HA precursor and titanium substrates. The in vitro biocompatibility of the laser cladded coatings and titanium substrate was investigated by culturing of mouse MC3T3-E1 pre-osteoblast cell line and analyzing the cell viability, cell proliferation, and cell morphology. A significantly higher cell attachment and proliferation rate were observed for both laser cladded 100 wt.% HA and 25 wt.% SiO 2 -HA samples. Compared to 100 wt.% HA sample, 25 wt.% SiO 2 -HA samples presented a slightly improved cellular interaction due to the addition of SiO 2 . The staining of the actin filaments showed that the laser cladded samples induced a normal cytoskeleton and well-developed focal adhesion contacts. Scanning electron microscopic image of the cell cultured samples revealed better cell attachment and spreading for 25 wt.% SiO 2 -HA and 100 wt.% HA coatings than titanium substrate. These results suggest that the laser cladding process improves the bioactivity and biocompatibility of titanium. The observed biological improvements are mainly due to the coating induced changes in surface chemistry and surface morphology. Highlights: → Laser cladding of Ti alloys with bioceramics creates new phases. → Laser cladded samples with SiO 2 -doped

  14. Osteoblast interaction with laser cladded HA and SiO{sub 2}-HA coatings on Ti-6Al-4V

    Energy Technology Data Exchange (ETDEWEB)

    Yang Yuling [Department of Physics, Northeastern University, Shenyang 110004 (China); Department of Materials Science and Engineering, University of Tennessee, Knoxville, TN 37996 (United States); Serpersu, Kaan [Department of Materials Science and Engineering, University of Tennessee, Knoxville, TN 37996 (United States); He Wei, E-mail: whe5@utk.edu [Department of Materials Science and Engineering, University of Tennessee, Knoxville, TN 37996 (United States); Department of Mechanical, Aerospace and Biomedical Engineering, University of Tennessee, Knoxville, TN 37996 (United States); Paital, Sameer R. [Department of Materials Science and Engineering, University of Tennessee, Knoxville, TN 37996 (United States); Dahotre, Narendra B. [Department of Materials Science and Engineering, University of North Texas, Denton, TX 76207 (United States)

    2011-12-01

    In order to improve the bioactivity and biocompatibility of titanium endosseous implants, the morphology and composition of the surfaces were modified. Polished Ti-6Al-4V substrates were coated by a laser cladding process with different precursors: 100 wt.% HA and 25 wt.% SiO{sub 2}-HA. X-ray diffraction of the laser processed samples showed the presence of CaTiO{sub 3}, Ca{sub 3}(PO{sub 4}){sub 2}, and Ca{sub 2}SiO{sub 4} phases within the coatings. From in vitro studies, it was observed that compared to the unmodified substrate all laser cladded samples presented improved cellular interactions and bioactivity. The samples processed with 25 wt.% SiO{sub 2}-HA precursor showed a significantly higher HA precipitation after immersion in simulated body fluid than 100 wt.% HA precursor and titanium substrates. The in vitro biocompatibility of the laser cladded coatings and titanium substrate was investigated by culturing of mouse MC3T3-E1 pre-osteoblast cell line and analyzing the cell viability, cell proliferation, and cell morphology. A significantly higher cell attachment and proliferation rate were observed for both laser cladded 100 wt.% HA and 25 wt.% SiO{sub 2}-HA samples. Compared to 100 wt.% HA sample, 25 wt.% SiO{sub 2}-HA samples presented a slightly improved cellular interaction due to the addition of SiO{sub 2}. The staining of the actin filaments showed that the laser cladded samples induced a normal cytoskeleton and well-developed focal adhesion contacts. Scanning electron microscopic image of the cell cultured samples revealed better cell attachment and spreading for 25 wt.% SiO{sub 2}-HA and 100 wt.% HA coatings than titanium substrate. These results suggest that the laser cladding process improves the bioactivity and biocompatibility of titanium. The observed biological improvements are mainly due to the coating induced changes in surface chemistry and surface morphology. Highlights: {yields} Laser cladding of Ti alloys with bioceramics creates new

  15. From ISO 9001:2008 to ISO 9001:2015: Significant changes and their impacts to aspiring organizations

    Science.gov (United States)

    Sari, Y.; Wibisono, E.; Wahyudi, R. D.; Lio, Y.

    2017-11-01

    ISO 9001:2015 is the latest version of ISO Quality Management System standard that has been updated recently from ISO 9001:2008. It is necessary for all organizations that have implemented and been certified with ISO 9001:2008 to prepare the transition and upgrade their Quality Management System because the certification will expire by September 2018. This paper attempts to provide knowledge on the significant changes from ISO 9001:2008 to ISO 9001:2015, what new requirements are added, and how they would impact the organizations. An exploratory and applied research was chosen as the research approach and aimed to explore what transition designs are needed to anticipate the changes as well as their impacts. The research applied a methodology of Plan-Do-Check-Action (PDCA) cycle into four organizations and their results were compared and discussed to explain the transition designs. Some qualitative methods such as observation and interview were used to collect the data. By addressing the new requirements, three transition designs that should be prepared are: (i) identifying needs from interested parties, (ii) analyzing internal and external factors of the organizations to formulate relevant strategies and quality objectives, and (iii) registering risks associated to business processes as well as organizational strategies.

  16. Discussion on the compilation of document of iso quality management system for radiation sterilization enterprises

    International Nuclear Information System (INIS)

    Li Chunhong; Ha Yiming; Zhou Hongjie; Feng Zhiguo; Wang Feng

    2006-01-01

    According to the character of cooperation of radiation sterilization, and association with request of ISO9001, ISO13485 and ISO11137, compilation of document in quality manual, procedure document and technological document during certification of ISO quality management system of cooperation of radiation sterilization was discussed. (authors)

  17. 77 FR 11532 - Notice of Attendance at ISO New England and NEPOOL Meetings

    Science.gov (United States)

    2012-02-27

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Notice of Attendance at ISO New England... members of the Commission and Commission staff may attend upcoming ISO New England Inc. (ISO-NE) and New..., the Commission and Commission staff may monitor the various meetings posted on the ISO-NE Web site...

  18. ISO celebrates its prolonged life with a video of Jupiter

    Science.gov (United States)

    1997-07-01

    This is excellent news for astronomers and especially for the multinational teams, with leaders in France, Germany, the Netherlands and the United Kingdom, who spent many years devising the four instruments served by ISO's telescope. The camera ISOCAM, the photometer ISOPHOT, the Short Wavelength Spectrometer and the Long Wavelength Spectrometer span between them an unprecedented range of infrared wavelengths from 2 to 200 microns. The atmosphere of Jupiter is one of the cool and cloudy places attracting ISO's attention, and ESA today releases a video of unprecedented images of Jupiter. The planet changes its appearance drastically as the camera ISOCAM scans a range of 90 different infrared wavelengths. Picture by picture, ISOCAM picks out different features of the atmosphere's composition and behaviour. These and other results from ISO will enable scientists to sharpen their ideas about how Jupiter's weather works. "ISO is giving us a new impression of the giant planets of the Solar System," comments Roger Bonnet, ESA's director of science. "Not just Jupiter, but Saturn, Uranus and Neptune too. By observing the planets across its very wide range of infrared wavelengths, ISO can see features overlooked even by spacecraft visiting the planets. The remarkable movie of Jupiter released today represents only a few per cent of ISO's wavelength range, yet every image tells its own story." More information about the Jupiter video appears later in this Information Note. How ISO's cold telescope beat the calendar The need to keep ISO's telescope and instruments chilled to a very low temperature sets a limit to their useful operating life. ISO was supplied with more than 2000 litres of superfluid helium to cool it. Slow evaporation maintains key parts of the spacecraft at temperatures close to absolute zero, below minus 271 degrees C. The rate of loss of helium was expected to be about 3 litres a day, but the cryogenic system could not be tested in exactly the conditions

  19. CILogon-HA. Higher Assurance Federated Identities for DOE Science

    Energy Technology Data Exchange (ETDEWEB)

    Basney, James [Univ. of Illinois, Urbana-Champaign, IL (United States)

    2015-08-01

    The CILogon-HA project extended the existing open source CILogon service (initially developed with funding from the National Science Foundation) to provide credentials at multiple levels of assurance to users of DOE facilities for collaborative science. CILogon translates mechanism and policy across higher education and grid trust federations, bridging from the InCommon identity federation (which federates university and DOE lab identities) to the Interoperable Global Trust Federation (which defines standards across the Worldwide LHC Computing Grid, the Open Science Grid, and other cyberinfrastructure). The CILogon-HA project expanded the CILogon service to support over 160 identity providers (including 6 DOE facilities) and 3 internationally accredited certification authorities. To provide continuity of operations upon the end of the CILogon-HA project period, project staff transitioned the CILogon service to operation by XSEDE.

  20. Prospects of HA-Based Universal Influenza Vaccine

    Directory of Open Access Journals (Sweden)

    Anwar M. Hashem

    2015-01-01

    Full Text Available Current influenza vaccines afford substantial protection in humans by inducing strain-specific neutralizing antibodies (Abs. Most of these Abs target highly variable immunodominant epitopes in the globular domain of the viral hemagglutinin (HA. Therefore, current vaccines may not be able to induce heterosubtypic immunity against the divergent influenza subtypes. The identification of broadly neutralizing Abs (BnAbs against influenza HA using recent technological advancements in antibody libraries, hybridoma, and isolation of single Ab-secreting plasma cells has increased the interest in developing a universal influenza vaccine as it could provide life-long protection. While these BnAbs can serve as a source for passive immunotherapy, their identification represents an important step towards the design of such a universal vaccine. This review describes the recent advances and approaches used in the development of universal influenza vaccine based on highly conserved HA regions identified by BnAbs.

  1. ISO 50001 for US Commercial Buildings - Current Status and Opportunities

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Jingjing; Sheaffer, Paul

    2017-12-01

    ''ISO 50001: 2011 Energy management systems – Requirements with guidance for use'' is a voluntary International Standard which provides organizations a proven framework to manage energy and continuously improve their energy performance. Implementing ISO 50001 in the commercial building sector has its unique opportunities and challenges in comparison with the industrial sector. The energy footprint of a portfolio of commercial buildings can be just as significant as a large industrial facility in comparison. There are many energy-saving opportunities in commercial buildings that can be addressed without capital investments, and the perceived risks for making energy improvements can be lower than in the industrial sector. In addition, the energy-consuming systems in commercial buildings are limited in types and have many similarities across buildings, which makes it much easier to standardize many ISO 50001 required processes, 5 procedures and documents to simplify implementation. There are also some sector-unique challenges, such as less familiar with ISO systems and the certification process. Another challenge arises from the complexity in some buildings’ ownership, tenancy, and O&M responsibilities. This whitepaper discusses these opportunities and issues in detail. The paper also recommends the characteristics of organizations in the commercial building sector that can benefit the most from adopting the ISO 50001 standard – namely the “suitable market”. Eight segments (education, food sales, retail, inpatient health care, hospitality, office buildings, laboratories and data centers) within the commercial building sector are highlighted.

  2. Gloss uniformity measurement update for ISO/IEC 19751

    Science.gov (United States)

    Ng, Yee S.; Cui, Chengwu; Kuo, Chunghui; Maggard, Eric; Mashtare, Dale; Morris, Peter

    2005-01-01

    To address the standardization issues of perceptually based image quality for printing systems, ISO/IEC JTC1/SC28, the standardization committee for office equipment chartered the W1.1 project with the responsibility of drafting a proposal for an international standard for the evaluation of printed image quality1. An ISO draft Standard2, ISO/WD 19751-1, Office Equipment - Appearance-based image quality standards for printers - Part 1: Overview, Procedure and Common Methods, 2004 describes the overview of this multi-part appearance-based image quality standard. One of the ISO 19751 multi-part Standard"s tasks is to address the appearance-based gloss and gloss uniformity issues (in ISO 19751-2). This paper summarizes the current status and technical progress since the last two updates3, 4. In particular, we will be discussion our attempt to include 75 degree gloss (G75) objective measurement5 in differential gloss and within-page gloss uniformity. The result for a round-robin experiment involving objective measurement of differential gloss using G60 and G75 gloss measurement geometry is described. The results for two perceptual-based round-robin experiments relating to haze effect on the perception of gloss, and gloss artifacts (gloss streaks/bands, gloss graininess/mottle) are discussed.

  3. Establishing an ISO 10001-based promise in inpatients care.

    Science.gov (United States)

    Khan, Mohammad Ashiqur Rahman; Karapetrovic, Stanislav

    2015-01-01

    The purpose of this paper is to explore ISO 10001:2007 in planning, designing and developing a customer satisfaction promise (CSP) intended for inpatients care. Through meetings and interviews with research participants, who included a program manager, unit managers and registered nurses, information about potential promises and their implementation was obtained and analyzed. A number of promises were drafted and one was finally selected to be developed as a CSP. Applying the standard required adaptation and novel interpretation. Additionally, ISO 10002:2004 (Clause 7) was used to design the feedback handling activities. A promise initially chosen for development turned out to be difficult to implement, experience that helped in selecting and developing the final promise. Research participants found the ISO 10001-based method useful and comprehensible. This paper presents a specific health care example of how to adapt a standard's guideline in establishing customer promises. The authors show how a promise can be used in alleviating an existing issue (i.e. communication between carers and patients). The learning can be beneficial in various health care settings. To the knowledge, this paper shows the first example of applying ISO 10001:2007 in a health care case. A few activities suggested by the standard are further detailed, and a new activity is introduced. The integrated use of ISO 10001:2007 and 10002:2004 is presented and how one can be "augmented" by the other is demonstrated.

  4. Effect of Water-Glass Coating on HA and HA-TCP Samples for MSCs Adhesion, Proliferation, and Differentiation

    Directory of Open Access Journals (Sweden)

    Indu Bajpai

    2016-01-01

    Full Text Available Ca-P and silicon based materials have become very popular as bone tissue engineering materials. In this study, water-glass (also known as sodium silicate glass was coated on sintered hydroxyapatite (HA and HA-TCP (TCP stands for tricalcium phosphate samples and subsequently heat-treated at 600°C for 2 hrs. X-rays diffraction showed the presence of β- and α-TCP phases along with HA in the HA-TCP samples. Samples without coating, with water-glass coating, and heat-treated after water-glass coating were used to observe the adhesion and proliferation response of bone marrow derived-mesenchymal stem cells (MSCs. Cell culture was carried out for 4 hrs, 1 day, and 7 days. Interestingly, all samples showed similar response for cell adhesion and proliferation up to 7-day culture but fibronectin, E-cadherin, and osteogenic differentiation related genes (osteocalcin and osteopontin were significantly induced in heat-treated water-glass coated HA-TCP samples. A water-glass coating on Ca-P samples was not found to influence the cell proliferation response significantly but activated some extracellular matrix genes and induced osteogenic differentiation in the MSCs.

  5. ISO 9001 benefits and pitfalls: the path to successful certification.

    Science.gov (United States)

    Krause, M S

    1996-09-01

    The lifeblood of a business is developing and commercializing new products with minimum cost and time and maximum quality. Implementation of a quality management system is often used to achieve these goals, and the ISO 9001 standard for a business quality system is rapidly becoming the model of choice. The existence of an ISO-compliant system is a key to meeting the forthcoming regulatory requirements in the European Union and the US Food and Drug Administrations's proposed good management practices. DuPont has demonstrated leadership in the achievement of ISO registration. I describe the path to these successful registrations along with key lessons from the experience. Elements of success are management commitment, adequate resources, education, communication, total organizational involvement, and auditing of system performance. For the system to flourish and provide benefits to the users, sufficient time must be allocated for the organization to change.

  6. ISO 9001 and ISO 14001: An Integrated Quality Management System for an MTR Facility SAFARI-1 Research Reactor

    International Nuclear Information System (INIS)

    Du Bruyn, J.F.; Piani, C.S.B.

    2005-01-01

    The SAFARI-1 research reactor, owned and operated by the South African Nuclear Energy Corporation (Necsa), initially obtained ISO 9001 accreditation of its Quality, Health, Safety and Environmental (QHSE) management system via international affiliation from the South African Bureau of Standards (SABS) during 1998 and re-certification according to ISO 9001 (2000) in 2003. With ever-increasing demands on nuclear facilities to demonstrate conformance to environmental policies, SAFARI-1 has now developed an Environmental Management System (EMS) that is compliant with ISO 14001 (1996) and is fully integrated with the SAFARI-1 Quality Management System (QMS). The dynamic involvement of SAFARI-1 in commercial applications demanded that any transition of the original QMS to a fully incorporated QHSE system had to be done in a way that would ensure sustained delivery of a safe and reliable service with continuous quality. At the same time, the primary vision of operating a facility under an efficient financial management programme was essential. The criteria established by the original ISO 9001 compliant QMS were appraised against the additional requirements of ISO 14001 and a suitable superstructure derived for generation and implementation of an inclusive EMS. The transitional integration of this system was planned so as to produce a QMS suitable to quality, environmental and other management related issues for application to the unique function of a nuclear research reactor. (author)

  7. ISO 14000: Review and guidelines for the photovoltaic industry

    Energy Technology Data Exchange (ETDEWEB)

    DePhillips, M.P.

    1997-08-01

    The International Organization for Standardization (ISO) has released and is in the process of ratifying a new set of environmental management system standards, ISO 14000. These voluntary international standards will have a significant impact on how companies throughout the international community manage their environmental programs. Initially this impact will result in increased international trade opportunities due to the anticipated customer requirement for suppliers to demonstrate certification. Other potential impacts will benefit both companies engaged in international commerce and companies with a domestic focus. These would include installing a cohesive system to manage environmental matters, participation within a new regulatory paradigm, and adhering to a potentially new set of legal standards. The wide range of potential environmental, commercial, legal and regulatory benefits offered by ISO 14000 offer most companies significant reason to explore the possibilities of implementing an environmental management system. Organizations will be able to anticipate and meet growing environmental expectations and to ensure ongoing compliance with national and international requirements as well as satisfy the growing demands of customers, stakeholders and the interested public. As an emerging industry with significant international ties, the photovoltaic (PV) community will be effected from these standards if they do become globally adopted. In fact some major players in the PV industry have recently received certification to ISO 9000. This again demonstrates a trend within the industry to move toward a uniform system approach to management. This paper will expose interested parties within the PV industry to the details of ISO 14000 and will assist decision makers assess the various possibilities for implementation certification of ISO 14000 for an individual facility.

  8. Progress report on the management of the NEA ISOE system

    Energy Technology Data Exchange (ETDEWEB)

    Lazo, E. [OECD Nuclear Energy Agency, Issy-les-Moulineaux (France)

    1995-03-01

    The Information System on Occupational Exposure (ISOE) was launched by the Organization for Economic Cooperation and Development (OECD), Nuclear Energy Agency (NEA) on 1 January, 1992, to facilitate the communication of dosimetric and ALARA implementation data among nuclear utilities around the world. After two years of operation the System has become a mature interactive network for transfer of data and experience. Currently, 37 utilities from 12 countries, representing 289 power plants, and 12 national regulatory authorities participate in ISOE. Agreements for cooperation also exist between the NEA and the Commission of the European Communities (CEC), and the Paris Center of the WOrld Association of Nuclear Operators (WANO-PC). In addition, the International Atomic Energy Agency (IAEA) is acting as a co-sponsor of ISOE for the participation of non-NEA member countries. Three Regional Technical Centres, Europe, Asia, and Non-NEA member countries, serve to administer the system. The ISOE Network is comprised of three data bases and a communications network at several levels. The three ISOE data bases include the following types of information: NEA1 - annual plant dosimetric information; NEA2 - plant operational characteristics for dose and dose rate reduction; and NEA3 - job specific ALARA practices and experiences. The ISOE communications network has matured greatly during 1992 and 1993. In addition to having access to the above mentioned data bases, participants may now solicit information on new subjects, through the Technical Centres, from all other participants on a real-time basis. Information Sheets on these studies are produced for distribution to all participants. In addition, Topical Reports on areas of interest are produced, and Topical Meetings are held annually.

  9. Progress report on the management of the NEA ISOE system

    International Nuclear Information System (INIS)

    Lazo, E.

    1995-01-01

    The Information System on Occupational Exposure (ISOE) was launched by the Organization for Economic Cooperation and Development (OECD), Nuclear Energy Agency (NEA) on 1 January, 1992, to facilitate the communication of dosimetric and ALARA implementation data among nuclear utilities around the world. After two years of operation the System has become a mature interactive network for transfer of data and experience. Currently, 37 utilities from 12 countries, representing 289 power plants, and 12 national regulatory authorities participate in ISOE. Agreements for cooperation also exist between the NEA and the Commission of the European Communities (CEC), and the Paris Center of the WOrld Association of Nuclear Operators (WANO-PC). In addition, the International Atomic Energy Agency (IAEA) is acting as a co-sponsor of ISOE for the participation of non-NEA member countries. Three Regional Technical Centres, Europe, Asia, and Non-NEA member countries, serve to administer the system. The ISOE Network is comprised of three data bases and a communications network at several levels. The three ISOE data bases include the following types of information: NEA1 - annual plant dosimetric information; NEA2 - plant operational characteristics for dose and dose rate reduction; and NEA3 - job specific ALARA practices and experiences. The ISOE communications network has matured greatly during 1992 and 1993. In addition to having access to the above mentioned data bases, participants may now solicit information on new subjects, through the Technical Centres, from all other participants on a real-time basis. Information Sheets on these studies are produced for distribution to all participants. In addition, Topical Reports on areas of interest are produced, and Topical Meetings are held annually

  10. Improving natural resource management in Viet Nam's Hong Ha ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    2011-07-15

    Jul 15, 2011 ... Improving natural resource management in Viet Nam's Hong Ha commune ... In this work, the research team helped local farmers improve their land ... with a home garden economy, limit forest destruction, diversify crop production, ... low female participation rates in decision making; limited education; rapid ...

  11. Mao & Püha Eliisabet / Jüri Kuuskemaa

    Index Scriptorium Estoniae

    Kuuskemaa, Jüri, 1942-

    2000-01-01

    Kadrioru lossis Väliskunstimuuseumi ekspositsioonis olevast antikvaar August Käbi pärandist pärit maalist. Kunstiteadlase Mai Levini arvates võib maali autoriks olla Rooma kunstnik Tommaso Salini, hüüdnimega Mao. Maali süzee: "Püha Eliisabeti kuulutus". 1 ill

  12. Läkaköha - aktuaalne uurimisteema / Marje Oona

    Index Scriptorium Estoniae

    Oona, Marje, 1963-

    2012-01-01

    TÜ peremeditsiini õppetooli töötajate poolt algatatud uurimistööst, mille eesmärgiks on uurida Bordetella spp. infektsioonide epidemioloogiat, molekulaargeneetikat ja kliinilisi eripärasid ning selgitada läkaköha sagedasema diagnsimise põhjusi Eestis

  13. Managing your library and its quality the ISO 9001 way

    CERN Document Server

    Balagué, Núria

    2011-01-01

    This book, divided into two parts, provides an introduction to the quality management issues and gives a general overview to the use of ISO 9001 in the library environment. The second part presents the main features of ISO 9001:2008 with practical comments and examples on how to implement its clauses in libraries. Whether in the public or in the private sector, libraries can be seen as service organisations: they act in very dynamic environments where users are increasingly demanding new types of services. Thus the adoption of a quality management system helps each library in meeting the needs

  14. U-value measurements on ISO round Robin window

    DEFF Research Database (Denmark)

    Duer, Karsten

    1997-01-01

    9 laboratories in 6 european and 2 north american countries have participated in a round robin U-value test of a standard facade window. The objective of the round robin test was to verify that the ISO/CEN proposals for U-value measurement standard is robust.......9 laboratories in 6 european and 2 north american countries have participated in a round robin U-value test of a standard facade window. The objective of the round robin test was to verify that the ISO/CEN proposals for U-value measurement standard is robust....

  15. Mednarodni standardi - veličine in enote (ISO 31-0 do 31-13): International standards - quantities and units (ISO 31-0 to 31-13):

    OpenAIRE

    Glavič, Peter

    2002-01-01

    In this paper the international standards ISO 31 (Quantities and units) are presented with the following parts: ISO 31-0 (General principles), ISO 31-1 (Space and time), ISO 31-2 (Periodic and related phenomena), ISO 31-3 (Mechanics), ISO 31-4 (Heat), ISO 31-5 (Electricity and magnetism), ISO 31-8 (Physical chemistry and molecular physics), ISO 31-12 (Characteristic numbers)and others. The emphasis is given on the basic principles, which is important for writing of reports, presentations, art...

  16. New water and remote galaxies complete ISO's observations

    Science.gov (United States)

    ISO's operational teams at ESA's ground station at Villafranca near Madrid have been hurrying to provide the world's astronomers with as many observations as possible. They have long anticipated the exhaustion of ISO's vital supply of liquid helium, which cooled the infrared telescope and its instruments to their operating temperatures, close to absolute zero. Two weeks after ISO was put into orbit on 17 November 1995 by an Ariane 44P launcher, the external parts of the cooling system had settled to the operating temperature. The specification required that ISO should then operate for at least 18 months -- implying that operations might have to end in May 1997. Thanks to superb engineering by European industry, which built the spacecraft and its super-cool telescope, ISO has given astronomers almost a year longer than that. During the extra time the count of ISO's observations of cosmic objects has risen from 16,000 to about 26,000. Among the benefits of ISO's longevity has been the chance to examine an important region of the sky, in and around the constellation of Orion. This was not accessible in the nominal mission but has now been observed in two periods. Four inter national teams, supported by national funding agencies, supplied the instruments to analyse the infrared rays received by ISO's telescope. The principal investigators leading the teams are Dietrich Lemke (Heidelberg, Germany) for the versatile photometer ISOPHOT, Catherine Cesarsky (Saclay, France) for the camera ISOCAM, Thijs de Graauw (Groningen, the Netherlands) for the Short Wavelength Spectrometer SWS, and Peter Clegg (London, UK) for the Long Wavelength Spectrometer LWS. Water vapour on Titan A big difference between ISO and the only previous infrared astronomy satellite (IRAS 1983) has been its ability to examine individual objects across a wide range of accurately defined infrared wavelengths. Many spectra showing patterns of intensities at the different wavelengths have enabled astronomers

  17. The ISO 14001 Environmental Management Systems as a Motivation

    African Journals Online (AJOL)

    user1

    Two case studies were selected namely Plant A (a dairy plant) ... ISO 14001 certified and it is making use these indicators for its energy and .... community, public health, skills and education, social justice, workplace safety ..... Plant A holds good relations with its neighbourhood community. ... The plant sponsors its nearby.

  18. X(3872) and Its Iso-Triplet Partners

    OpenAIRE

    Kunihiko, TERASAKI; Yukawa Institute for Theoretical Physics, Kyoto University:Institute for Theoretical Physics, Kanazawa University

    2012-01-01

    Decays of X(3872) and its partners as hidden-charm axial-vector tetra-quark mesons are studied. As the result, it is seen that the iso-triplet partners of X(3872) can be broad, and therefore, higher statistics will be needed to find them.

  19. First Results of ISO-SWS Grating Observations of Jupiter

    NARCIS (Netherlands)

    Encrenaz, Th.; de Graauw, Th.; Schaeidt, S.; Lellouch, E.; Feuchtgruber, H.; Beintema, D. A.; Bezard, B.; Drossart, P.; Griffin, M.; Heras, A.; Kessler, M.; Leech, K.; Morris, A.; Roelfsema, P. R.; Roos-Serote, M.; Salama, A.; Vandenbussche, B.; Valentijn, E. A.; Davies, G. R.; Naylor, D. A.

    1996-01-01

    The spectrum of Jupiter has been recorded on April 12, 1996, between 2.75 and 14.5 mu m, with the grating mode of the Short-Wavelength Spectrometer of ISO (Infrared Space Observatory). The resolving power is 1500 and the sensitivity limit is better than 1 Jy. The corresponding S/N ratio is better

  20. First results of ISO-SWS observations of Jupiter

    NARCIS (Netherlands)

    Encrenaz, T.; de Graauw, T.; Schaeidt, S.; Lellouch, E.; Feuchtgruber, H.; Beintema, D. A.; Bezard, B.; Drossart, P.; Griffin, M.; Heras, A.; Kessler, M.; Leech, K.; Morris, P.; Roelfsema, P. R.; Roos-Serote, M.; Salama, A.; Vandenbussche, B.; Valentijn, E. A.; Davis, G. R.; Naylor, D. A.

    The spectrum of Jupiter has been recorded between 2.75 and 14.5 mu m with the grating mode of the Short-Wavelength Spectrometer (SWS) of ISO. The resolving power is 1500. The main preliminary results of this observation are (1) at 3 mu m, the first spectroscopic signature, probably associated with

  1. The soul of the machine: continual improvement in ISO 14001

    NARCIS (Netherlands)

    Brouwer, M.A.C.; van Koppen, C.S.A.

    2008-01-01

    Continual improvement is a key component of ISO 14001, but in contrast to most other specifications in the standard, it is difficult to assess. Based on interviews with 19 certified companies in the chemical, food, and environmental services sectors, this article explores the dynamics of continual

  2. The soul of the machine: continual improvement in ISO 14001.

    NARCIS (Netherlands)

    Brouwer, M.A.C.; Koppen, van C.S.A.

    2008-01-01

    Continual improvement is a key component of ISO 14001, but in contrast to most other specifications in the standard, it is difficult to assess. Based on interviews with 19 certified companies in the chemical, food, and environmental services sectors, this article explores the dynamics of continual

  3. Covenants with Weak Swords: ISO 14001 and Facilities' Environmental Performance

    Science.gov (United States)

    Potoski, Matthew; Prakash, Aseem

    2005-01-01

    Voluntary environmental programs are codes of progressive environmental conduct that firms pledge to adopt. This paper investigates whether ISO 14001, a voluntary program with a weak sword--a weak monitoring and sanctioning mechanism--can mitigate shirking and improve participants' environmental performance. Sponsored by the International…

  4. [Effects of the ISO 15189 accreditation on Nagoya University Hospital].

    Science.gov (United States)

    Yoshiko, Kenichi

    2012-07-01

    The Department of Clinical Laboratory, Nagoya University Hospital acquired ISO 15189 accreditation in November, 2009. The operation of our Quality Management System (QMS) was first surveyed in October, 2010. In this paper, we reported the activity for the preparation and operation of our QMS and the effects of ISO 15189 accreditation. We investigated the changes in the number and content on nonconformities, incident reports and complaints before and after accreditation as indicators to evaluate the effect of ISO 15189 accreditation. Post accreditation, the number of nonconformities and incident reports decreased, seeming to show an improvement of quality of the laboratory activity; however, the number of complaints increased. We identified the increase of complaints at the phlebotomy station. There had been some problems with blood sampling in the past, but it seemed that staff had a high level of concern regarding these problems at the phlebotomy station and took appropriate measures to resolve the complaints. We confirmed that the ISO 15189 accreditation was instrumental in the improvements of the safety and efficiency on laboratory works. However there was a problem that increase of overtime works to operate the QMS. We deal with development of a laboratory management system using IT recourses to solve the problem.

  5. Information Asymmetries as Trade Barriers: ISO 9000 Increases International Commerce

    Science.gov (United States)

    Potoski, Matthew; Prakash, Aseem

    2009-01-01

    Spatial, cultural, and linguistic barriers create information asymmetries between buyers and sellers that impede international trade. The International Organization for Standardization's ISO 9000 program is designed to reduce these information asymmetries by providing assurance about the product quality of firms that receive its certification.…

  6. Management system - PNS ISO/IEC 17025:2005

    International Nuclear Information System (INIS)

    Baje, Perla F.

    2009-01-01

    Management system is a set of policies, processes and procedures needed for planning and execution in the core business area of the organization. It is a set of policies and objectives to direct and control an organization with regard to quality. ISO 17025:2005 is the administrative and technical systems that govern the operations of the laboratory

  7. The ISO 5-pass authentication in χ-Spaces

    DEFF Research Database (Denmark)

    Cáccamo, Mario J.; Crazzolara, Federico; Milicia, Giuseppe

    2002-01-01

    We implement the ISO 5-pass authentication protocol and study its correctness using the χ-Space framework. χ-Spaces is a novel domain specific programming language designed for developing protocols and in particular security protocols. χ-Spaces programming language is an implementation of SPL...

  8. Physics motivation and concepts for the IsoSpin Laboratory

    International Nuclear Information System (INIS)

    Nitschke, J.M.

    1994-01-01

    In this article the author summarizes the issues which motivated the proposal for the IsoSpin Laboratory. Intense tunable radioactive ion beams can be used for studies in nuclear structure, nuclear reactions, astrophysics, and atomic physics and material science. The author discusses typical instrumentation needs of these experiments, as such a discussion is more limited than the range of experimental studies

  9. IMPLEMENTING AN ISO 10001-BASED PROMISE IN INPATIENTS CARE

    Directory of Open Access Journals (Sweden)

    Mohammad Ashiqur Rahman Khan

    2013-09-01

    Full Text Available This paper presents the implementation of a Customer Satisfaction Promise (CSP that requires nurses to introduce themselves and explain the care plan to the patients of a hospital unit in Canada. The CSP implementation, maintenance and improvement activities were based on ISO 10001:2007. Qualitative and quantitative performance data were collected from nurses, the unit manager and patients, and improvement suggestions were made. During the implementation, nurses introduced themselves 95% of the time and explained the care plan 86% of the time. When interviewed, some nurses stated that the CSP was a good reinforcement of a practice already expected of them, which made patients happy, satisfied and more comfortable. Data from a small sample of patients was not adequate in clearly indicating the CSP's performance or improvement, but was useful in validating the survey and the feedback form. To our knowledge, applications of ISO 10001:2007 in health care have not been studied. Furthermore, this paper may be the first example of the integrated use of ISO 10001 and ISO 10002 in health care.

  10. ISO 9000 and quality standards improvement in the maintenance ...

    African Journals Online (AJOL)

    This study investigated ISO 9000 as a tool for improving quality standards in ... The study used cross-sectional descriptive research design, using quantitative research ... enhance business performance and competiveness of manufacturing firms. ... By Country · List All Titles · Free To Read Titles This Journal is Open Access.

  11. The role of the IEC and ISO in radiological protection

    International Nuclear Information System (INIS)

    White, D.F.

    1976-01-01

    The history, objectives, structures and functions of the International Electrotechnical Commission (IEC) and the International Organisation for Standardisation (ISO) are summarized. The IEC is affiliated to the ISO as its electrical division, but has technical and financial autonomy. Member countries of the EEC may be committed to the adoption of their formal agreements ('Standards') if these become incorporated as Directives. The national standardisation organisations, such as BSI in the U.K., form national committees and are responsible for submitting to the IEC the co-ordinated national viewpoints on particular subjects. The overall links between the technical committees and sub-committees of the ISO, IEC and BSI in the field of radiological protection are tabulated, and the relevant International Standards produced, or in the course of preparation, by the appropriate committees of the ISO and the IEC are listed. The bulk of the effort of the BSI committees is now aimed at the production of acceptable international standards. Compatible national standards then follow. This policy is in contrast to the earlier initial emphasis on national standards, and the improved international collaboration has had two welcome effects. The selection of proposals for standards is more critical, and compatibility with the relevant ICRP and ICRU publications is almost a prerequisite for any international standard. (U.K.)

  12. The hidden networks of knowledge in ISO 14001

    DEFF Research Database (Denmark)

    Jørgensen, Ulrik

    2003-01-01

    The ISO 14001 standard is defined as a management standard based on an assumed existing knowledge base of what is to be considered being environmental problems. In the implementation of the standard is become evident, that its use and impact is entirely dependent of the existence of networks...

  13. ISO19770-1:2012 SAM process guidance

    CERN Document Server

    Canavan, Rory

    2012-01-01

    The pocket guide offers a concise summary of the principles of software asset management as conveyed by ISO 19770-1: 2012, and provides advice and guidance on how to kick-start your own SAM programme - something the Standard alone doesn't offer.

  14. ISO/IEC 38500 the IT governance standard

    CERN Document Server

    Calder, Alan

    2008-01-01

    The emergence of ISO/IEC 38500 - the international standard for the corporate governance of information and communication technology - puts boards around the world in a position from which they can take effective action to apply core governance principles to their information and communication technology.

  15. ISO 9000 and the total quality management models

    OpenAIRE

    Pacios Lozano, Ana Reyes

    1997-01-01

    Establishes the most outstanding differences between the ISO 9000 norms and total quality management as forms or manners of managing quality used in some information services. Compares two models of total quality: European Foundation far Quality Management and Malcolm Baldrige Awards.

  16. An Introduction to Information Security and ISO 27001

    CERN Document Server

    Watkins, Steve G

    2008-01-01

    This new pocket guide will suit both individuals who need an introduction to a topic that they know little about, and also organizations implementing, or considering implementing, some sort of information security management regime, particularly if using ISO/IEC 27001:2005

  17. Boiling Patterns of Iso-asymmetric Nuclear Matter

    International Nuclear Information System (INIS)

    Tõke, Jan

    2013-01-01

    Limits of thermodynamic metastability of self-bound neutron-rich nuclear matter are explored within the framework of microcanonical thermodynamics of interacting Fermi Gas model in Thomas-Fermi approximation. It is found that as the excitation energy per nucleon of the system is increased beyond a certain limiting value, the system loses metastability and becomes unstable with respect to joint fluctuations in excitation energy per nucleon and in isospin per nucleon. As a result, part of the system is forced to boil off in a form of iso-rich non-equilibrated vapors. Left behind in such a process, identifiable with distillation, is a more iso-symmetric metastable residue at a temperature characteristic of its residual isospin content. With a progressing increase in the initial excitation energy per nucleon, more neutron-rich matter is boiled off and a more iso-symmetric residue is left behind with progressively increasing characteristic temperature. Eventually, when all excess neutrons are shed, the system boils uniformly with a further supply of excitation energy, leaving behind a smaller and smaller residue at a characteristic boiling-point temperature of iso-symmetric matter.

  18. Considerations about ISO 14001, and suggestions for the next revision

    DEFF Research Database (Denmark)

    Jørgensen, Tine Herreborg

    2006-01-01

    . The standard is a process standard that leaves room for interpretation at company level as well as among lead auditors from certifying bodies. A case study is presented and shows lack of life cycle thinking in product development. The paper suggests changes of ISO 14001:2004 in order to include a clear product...

  19. ISO 9001:2000--setting the standard for quality management.

    Science.gov (United States)

    Edelstein, M E

    2001-04-01

    How will you approach the next quality management initiative? This article offers an introduction to the ISO 9001:2000 quality management system standards that can be applied to the HIM industry and how these standards can improve your department's policies and procedures.

  20. [ISO 9001-2000 certification for refractive laser treatment].

    Science.gov (United States)

    Lebuisson, D A; Arson, B; Abenhaïm, A; Albou-Ganem, C; Assouline, M; Chong Sit, D; Danan, A; Montefiore, G; Montin, J-F; Nguyen-Khoa, J-L; Pietrini, D; Saragoussi, J-J; Trong, Th; Amar, R

    2005-05-01

    To obtain ISO 9001-2000 certification for laser corneal refractive treatment, never before sought in Europe. The consulting firm Veritas led the certification process with the clinic's staff manager. This ISO norm is dedicated to the implementation of a quality management system. We assessed and optimized all necessary resources, evaluating customer satisfaction using patient and referring-physician surveys. We started quality rounds including surgeons, nurses, and technicians. Based on this preparation, we redefined and explained all processes including staff responsibilities and necessary resources in the quality manual. The procedure lasted 14 months with substantial involvement on the part of the management. Unconditional ISO 9001-2000 certification was granted by the independent audit firm, BVQI, in december 2003 for refractive laser treatment. The 2000 version of the new ISO 9001-2000 seeks to meet the demand for improving health care delivery in this field, most particularly by establishing a clear procedural orientation. Such certification enhances team work, stabilizes methodologies, and reinforces cohesion and self-audit. Patients notice that the center follows a consistent quality policy and are assured that the clinic respects rules and regulations. Certification is an advantageous alternative when accreditation cannot be considered. Our article discusses the steps taken in upper management, quality management, procedural guidance, as well as customer and staff counselling. It also discusses the project's cost/benefit ratio for the organization.

  1. Imaging of Homeostatic, Neoplastic, and Injured Tissues by HA-Based Probes

    Science.gov (United States)

    Veiseh, Mandana; Breadner, Daniel; Ma, Jenny; Akentieva, Natalia; Savani, Rashmin C; Harrison, Rene; Mikilus, David; Collis, Lisa; Gustafson, Stefan; Lee, Ting-Yim; Koropatnick, James; Luyt, Leonard G.; Bissell, Mina J.; Turley, Eva A.

    2013-01-01

    An increase in hyaluronan (HA) synthesis, cellular uptake, and metabolism occurs during the remodeling of tissue microenvironments following injury and during disease processes such as cancer. We hypothesized that multimodality HA-based probes selectively target and detectably accumulate at sites of high HA metabolism, thus providing a flexible imaging strategy for monitoring disease and repair processes. Kinetic analyses confirmed favorable available serum levels of the probe following intravenous (i.v.) or subcutaneous (s.c.) injection. Nuclear (technetium-HA, 99mTc-HA, and iodine-HA, 125I-HA), optical (fluorescent Texas Red-HA, TR-HA), and magnetic resonance (gadolinium-HA, Gd-HA) probes imaged liver (99mTc-HA), breast cancer cells/xenografts (TR-HA, Gd-HA), and vascular injury (125I-HA, TR-HA). Targeting of HA probes to these sites appeared to result from selective HA receptor-dependent localization. Our results suggest that HA-based probes, which do not require polysaccharide backbone modification to achieve favorable half-life and distribution, can detect elevated HA metabolism in homeostatic, injured, and diseased tissues. PMID:22066590

  2. Poredbena analiza Haških i Roterdamskih pravila

    Directory of Open Access Journals (Sweden)

    Vesna Skorupan Wolff

    2010-12-01

    Full Text Available Primjenom komparativne metode uspoređuju se najvažnije konvencijske odredbe i rješenja Roterdamskih pravila s onima sadržanim u Haškim pravilima. Raščlanjuje se većina recentnih odredbi Roterdamskih pravila koje predstavljaju ključne elemente po kojime se ona razlikuju od Haških pravila. U okviru toga ukazuje se na važnost novih pojmova, instituta i osoba koje sudjeluju u prijevoznom poslu. Govori se i o važnim odredbama koje su podudarne jer upravo brojna tradicionalna rješenja koja donose Roterdamska pravila mogu pridonijeti njihovom bržem i lakšem akceptiranju. Roterdamska pravila nastoje na suvremeni način urediti ugovore o prijevozu stvari morem, a pod određenim uvjetima primjenjivat će se i na prijevoze drugim prijevoznim granama. Opsežnost konvencije govori o njezinoj sveobuhvatnosti i velikoj preciznosti u propisivanju gotovo svih pitanja iz područja pravnog uređenja pomorskih prijevoznih ugovora, i više od toga, ona je jedinstven primjer temeljite raščlambe svih obveza i odgovornosti ugovornih stranaka i općenito svih subjekata koji se pojavljuju u prijevoznom poslu. Cilj poredbene analize Haških i Roterdamskih pravila je spoznati što novo donose Roterdamska pravila i procijeniti kako se ona uklapaju u postojeće pravno uređenje prijevoza stvari morem. Istodobno cilj je spoznati koje se odredbe Haških pravila danas izlažu kritici zbog njihove neprilagođenosti suvremenim uvjetima prijevoza i novim i drugačijim odnosima snaga između ugovornih strana u pomorskim prijevoznim ugovorima.

  3. Launching the chaotic realm of iso-fractals: A short remark

    Energy Technology Data Exchange (ETDEWEB)

    O' Schmidt, Nathan [Department of Mathematics, Boise State University, 1910 University Drive, Boise, ID 83725 (United States); Katebi, Reza [Department of Physics, California State University in Fullerton, 800 North State College Boulevard, Fullerton, CA 92831 (United States); Corda, Christian [Institute for Theoretical Physics and Advanced Mathematics Einstein-Galilei (IFM), Via Santa Gonda 14, 59100 Prato (Italy)

    2015-03-10

    In this brief note, we introduce the new, emerging sub-discipline of iso-fractals by highlighting and discussing the preliminary results of recent works. First, we note the abundance of fractal, chaotic, non-linear, and self-similar structures in nature while emphasizing the importance of studying such systems because fractal geometry is the language of chaos. Second, we outline the iso-fractal generalization of the Mandelbrot set to exemplify the newly generated Mandelbrot iso-sets. Third, we present the cutting-edge notion of dynamic iso-spaces and explain how a mathematical space can be iso-topically lifted with iso-unit functions that (continuously or discretely) change; in the discrete case examples, we mention that iteratively generated sequences like Fibonacci’s numbers and (the complex moduli of) Mandelbrot’s numbers can supply a deterministic chain of iso-units to construct an ordered series of (magnified and/or de-magnified) iso-spaces that are locally iso-morphic. Fourth, we consider the initiation of iso-fractals with Inopin’s holographic ring (IHR) topology and fractional statistics for 2D and 3D iso-spaces. In total, the reviewed iso-fractal results are a significant improvement over traditional fractals because the application of Santilli’s iso-mathematics arms us an extra degree of freedom for attacking problems in chaos. Finally, we conclude by proposing some questions and ideas for future research work.

  4. El griot no ha muerto, viva el hip-hop

    Directory of Open Access Journals (Sweden)

    Fco. Javier González García-Mamely

    2015-11-01

    Full Text Available La oratura en África ha jugado un papel vital a lo largo de los milenios como un (único medio de preservar y transmitir la historia, la cultura y el imaginario de cada comunidad. El griot es un claro modelo de las artes orales, pero ha sufrido cambios drásticos en su modo de vida y en los recursos narrativos de los que dispone. Tras el mecenazgo de los grandes reyes y las sucesivas llegadas del islam, el colonialismo y los procesos de modernización y occidentalización, los griots se han tenido que adaptar a nuevos patrones, audiencias y medios de comunicación, convirtiéndose en políticos o en figuras del espectáculo. La aparición del rap y el hip-hop reclamando ser los “modernos griots” ha ocasionado una respuesta crítica y una atracción viral hacia el nuevo fenómeno, sea éste un nuevo género o una reinvención de la oratura del antiguo griot.

  5. Reasons to Adopt ISO 50001 Energy Management System

    Directory of Open Access Journals (Sweden)

    Frederic Marimon

    2017-09-01

    Full Text Available Purpose: The main aim of this paper is to analyze the relationships between the corporate motivations that lead organizations to establish the ISO 50001 Energy Management System (EnMS standard, and the difficulties and benefits derived from its adoption. Design/methodology/approach: Three independent exploratory factor analyses (EFA were conducted in order to identify (i sources of motivation: social requirements, ecology drivers, and competitive advantage; (ii the difficulties of an ISO 50001 adoption: operational difficulties and organizational difficulty; and (iii types of benefits: ecological benefits and operational benefits. In a second step, an exploratory path analysis, performed through Structural Equation Modeling (SEM, was used to analyze the relations among motivation, difficulties, and benefits related to the adoption of the ISO 50001 standard. Findings: Social requirements explain operational difficulties, which in turn impacts on operational benefits. Ecology drivers are directly related to ecological benefits. Organizational difficulties have an inverse relationship with operational and ecological benefits. Operational difficulties are related to operational benefits and ecological benefits. Research limitations/implications: The questionnaire was disseminated to 87 Spanish companies with ISO 50001 certification. Managers and other practitioners such as consultants, auditing companies, and official organizations in charge of developing standards might find useful implications. Originality/value: The standard was published in 2011 by the International Organization for Standardization (ISO. This paper contributes to assessment of the benefits of the standard by collecting information directly from the pioneer organizations that have adopted it, and provides clues on how to implement the standard and improve it in future.

  6. ISO 15189 Accreditation: Navigation Between Quality Management and Patient Safety

    Directory of Open Access Journals (Sweden)

    Plebani Mario

    2017-09-01

    Full Text Available Accreditation is a valuable resource for clinical laboratories and the development of an International Standard for their accreditation represented a milestone on the path towards improved quality and safety in laboratory medicine. The recent revision of the International Standard, ISO 15189, has further strengthened its value not only for improving the quality system of a clinical laboratory but also for better answering the request for competence, focus on customers’ needs and ultimate value of laboratory services. Although in some countries more general standards such as ISO 9001 for quality systems or ISO 17025 for testing laboratories are still used, there is increasing recognition of the value of ISO 15189 as the most appropriate and useful standard for the accreditation of medical laboratories. In fact, only this International Standard recognizes the importance of all steps of the total testing process, namely extra-analytical phases, the need to focus on technical competence in addition to quality systems, and the focus on customers’ needs. However, the number of accredited laboratories largely varies between European countries and also major differences affect the approaches to accreditation promoted by the national bodies. In particular, some national accreditation bodies perpetuate the use of fixed scopes, while the European co-operation for accreditation (EA and the European Federation of Laboratory Medicine (EFLM Working Group promote the use of flexible scopes. Major issues in clinical laboratory accreditation are the verification of examination procedures for imprecision, trueness and diagnostic accuracy and for estimating measurement uncertainty. In addition, quality indicators (QIs are a fundamental requirement of the ISO 15189 International Standard.

  7. CONSECUENCIAS POSITIVAS DE LA IMPLANTACIÓN DE LA CERTIFICACIÓN ISO 14001 EN LAS EMPRESAS GALLEGAS (ESPAÑA.

    Directory of Open Access Journals (Sweden)

    Mª ANTONIA SEIJO-GARCÍA

    2013-01-01

    Full Text Available Este trabajo pretende analizar las consecuencias positivas derivadas de la implantación de la norma ISO 14001 en la comunidad autónoma de Galicia. Nos servimos para ello de una muestra representativa de empresas de la Comunidad Autónoma de Galicia a las que se les ha enviado la encuesta (ver anexo B. La realización de este estudio supone una mejora respecto a otros trabajos similares realizados en la comunidad ya que permiten entender de manera más pormenorizada la situación de la ISO 14001 en Galicia. Entre las consecuencias positivas detectadas destaca la mejora en la gestión medioambiental, lo que repercute en un ahorro económico y contribuye a mejorar la imagen de la empresa.

  8. Analysis of the Air Force ISO 14001 Pilot Study Conducted by DoD

    National Research Council Canada - National Science Library

    Harris, Rodney

    2000-01-01

    The Department of Defense (DoD) conducted an ISO 14001 pilot study with the primary goal of determining how ISO 14001 could help DoD organizations reduce risks, improve compliance with environmental regulations, enhance stewardship...

  9. [Efforts to achieve and effects of acquiring ISO 15189 in Tokushima University Hospital].

    Science.gov (United States)

    Shono, Kazuko; Kishi, Misako; Satou, Mituyo; Nagamine, Yasunori; Doi, Tosio

    2009-12-01

    The medical laboratory of Tokushima University Hospital acquired ISO 15189, an international standard for medical laboratories, on July 6th, 2007, resulting in it achieving the 24th place in Japan and 5th place among national university hospitals. The first surveillance was just performed on October 6th, 2008. Tokushima University Hospital, in which our medical laboratory is included as one section, already succeeded in acquiring ISO 9001, PrivacyMark System, and Quality Health Care ver. 5 before accomplishing ISO 15189. To achieve ISO 15189, we prepared documents based on ISO 9001 without any consultation, resulting in a review of the difference between ISO 9001 and ISO 15189 after the preliminary survey. Although achieving ISO 15189 resulted in an improvement in the reliability of laboratory results and accuracy, leading to the development of our technical skills and awareness, and sharing of knowledge, we consider that the considerable investment of time to prepare the requirements remains to be overcome.

  10. The HaDREB2 transcription factor enhances basal thermotolerance and longevity of seeds through functional interaction with HaHSFA9

    Directory of Open Access Journals (Sweden)

    Carranco Raúl

    2009-06-01

    Full Text Available Abstract Background Transcription factor HaDREB2 was identified in sunflower (Helianthus annuus L. as a drought-responsive element-binding factor 2 (DREB2 with unique properties. HaDREB2 and the sunflower Heat Shock Factor A9 (HaHSFA9 co-activated the Hahsp17.6G1 promoter in sunflower embryos. Both factors could be involved in transcriptional co-activation of additional small heat stress protein (sHSP promoters, and thus contribute to the HaHSFA9-mediated enhancement of longevity and basal thermotolerance of seeds. Results We found that overexpression of HaDREB2 in seeds did not enhance longevity. This was deduced from assays of basal thermotolerance and controlled seed-deterioration, which were performed with transgenic tobacco. Furthermore, the constitutive overexpression of HaDREB2 did not increase thermotolerance in seedlings or result in the accumulation of HSPs at normal growth temperatures. In contrast, when HaDREB2 and HaHSFA9 were conjointly overexpressed in seeds, we observed positive effects on seed longevity, beyond those observed with overexpression of HaHSFA9 alone. Such additional effects are accompanied by a subtle enhancement of the accumulation of subsets of sHSPs belonging to the CI and CII cytosolic classes. Conclusion Our results reveal the functional interdependency of HaDREB2 and HaHSFA9 in seeds. HaDREB2 differs from other previously characterized DREB2 factors in plants in terms of its unique functional interaction with the seed-specific HaHSFA9 factor. No functional interaction between HaDREB2 and HaHSFA9 was observed when both factors were conjointly overexpressed in vegetative tissues. We therefore suggest that additional, seed-specific factors, or protein modifications, could be required for the functional interaction between HaDREB2 and HaHSFA9.

  11. Iso-vector form factors of the delta and nucleon in QCD sum rules

    International Nuclear Information System (INIS)

    Ozpineci, A.

    2012-01-01

    Form factors are important non-perturbative properties of hadrons. They give information about the internal structure of the hadrons. In this work, iso-vector axial-vector and iso-vector tensor form factors of the nucleon and the iso-vector axial-vector Δ→N transition form factor calculations in QCD Sum Rules are presented.

  12. On the composition of ISO 25964 hierarchical relations (BTG, BTP, BTI)

    NARCIS (Netherlands)

    Alexiev, A; Isaac, A.H.J.C.A.; Lindenthal, J

    2015-01-01

    Knowledge organization systems (KOS) can use different types of hierarchical relations: broader generic (BTG), broader partitive (BTP), and broader instantial (BTI). The latest ISO standard on thesauri (ISO 25964) has formalized these relations in a corresponding OWL ontology (De Smedt et al., ISO

  13. Juhtimissüsteemide selgroog. Lean ning ISO - terviklahendused tootmise haldamiseks / Anton Ovsjankin

    Index Scriptorium Estoniae

    Ovsjankin, Anton

    2011-01-01

    Kasvanud on juurutatavate Lean ja ISO süsteemide arv, kuid on kasvanud ka nende juurutamise ja arendamisega seotud ebaõnnestumiste arv. Põhjustest, miks jäävad paljud Leani ja ISO juurutanud ettevõtted ilma lubatud tulemusteta. Leani ja ISO haldamiseks vajalikest teguritest

  14. ISO sertifikaat kuulutab tootja mainet üle maailma / Ain Alvela

    Index Scriptorium Estoniae

    Alvela, Ain, 1967-

    2006-01-01

    Ilmunud ka: Delovõje Vedomosti 12. apr. lk. 24-25. ISO standardi rakendamine tagab toodangu kvaliteedi ja annab firmale usaldusväärsuse. Kommenteerib Ain Noormägi. Vt. samas: ISO 9001; ISO 14 001; Universaalne standard kohandub ettevõtte vajadustega

  15. Antioxidant mechanisms of iso-6-cassine in suppressing seizures induced by pilocarpine

    Directory of Open Access Journals (Sweden)

    Rivelilson Mendes de Freitas

    2011-06-01

    Full Text Available The aim of this study was to evaluate the in vitro antioxidant effects of 12-[(2R,5R,6R-5-hydroxy-6-methylpiperidin-2-yl]dodecan-2-one (iso-6-cassine; ISO and the anticonvulsant effects of ISO on pilocarpine-induced seizures in rats. Wistar rats were treated with 0.9% saline (i.p., control group, pilocarpine (400 mg/kg, i.p., pilocarpine group, and the association of ISO (1.0 mg/kg, i.p. plus pilocarpine (400 mg/kg, i.p., 30 min after administration of ISO (ISO plus pilocarpine group. After the treatments all groups were observed for 1h. The antioxidant effect of ISO on the pilocarpine model was assessed by determining the activity of glutathione peroxidase (GPx, glutathione-S-transferase (GST and catalase (CAT as well as the levels of reactive species (RS and lipid peroxidation (LP. In vitro, ISO (5 μM reduced RS and LP. ISO (1.0 mg/kg and abolished seizures and death induced by pilocarpine in rats. ISO protected against the increase in the RS and LP levels, GST activity as well as the inhibition of GPx activity caused by pilocarpine. In addition, ISO increased the catalase activity in hippocampus of seized rats. In conclusion, the dta suggest that ISO can present anticonvulsant and antioxidant properties in the pilocarpine model of seizures in rats.

  16. 75 FR 5779 - Notice Providing Agenda for Technical Conference on RTO/ISO Responsiveness

    Science.gov (United States)

    2010-02-04

    ... Conference on RTO/ISO Responsiveness January 27, 2010. California Independent System Operator Docket No. ER09.... Southwest Power Pool, Inc Docket Nos. ER09-1050-000, ER09- 1192-000. ISO New England, Inc. and New England.... Agenda--Technical Conference on RTO/ISO Responsiveness February 4, 2010 12:30 Panel 1--Stakeholder...

  17. 75 FR 51996 - Notice of Commission Staff Attendance at Midwest ISO Meetings

    Science.gov (United States)

    2010-08-24

    ... Midwest ISO Meetings August 16, 2010. The Federal Energy Regulatory Commission hereby gives notice that members of the Commission and Commission staff may attend the following Midwest ISO-related meetings...., St. Paul, MN) [cir] September 15 [cir] October 20 [cir] November 17 [cir] December 1 Midwest ISO...

  18. 75 FR 16096 - New England Power Generators Association Inc., Complainant v. ISO New England Inc., Respondent...

    Science.gov (United States)

    2010-03-31

    ...-787-000] New England Power Generators Association Inc., Complainant v. ISO New England Inc., Respondent; ISO New England Inc. and New England Power Pool; Notice of Complaint March 24, 2010. Take notice... Inc. (Complainant) filed a formal complaint against ISO New England Inc. (Respondent) alleging that...

  19. 78 FR 38027 - ISO New England Inc.; Notice of Initiation of Proceeding and Refund Effective Date

    Science.gov (United States)

    2013-06-25

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. EL13-72-000] ISO New England... III.A.15 of Appendix A of ISO New England Inc.'s existing tariff. Dominion Energy Marketing, Inc. and ISO New England Inc., 143 FERC ] 61,233 (2013). The refund effective date in Docket No. EL13-72-000...

  20. 76 FR 4104 - Notice of Commission Staff Attendance at Midwest ISO Meetings

    Science.gov (United States)

    2011-01-24

    ... Midwest ISO Meetings January 13, 2011. The Federal Energy Regulatory Commission hereby gives notice that members of the Commission and Commission staff may attend the following Midwest ISO-related meetings...] September 14 [cir] October 19 [cir] November 16 [cir] December 6 Midwest ISO Informational Forum (3 p.m.-5 p...

  1. 75 FR 3228 - Notice of Commission Staff Attendance at Midwest ISO Meetings

    Science.gov (United States)

    2010-01-20

    ... Midwest ISO Meetings January 12, 2010. The Federal Energy Regulatory Commission hereby gives notice that members of the Commission and Commission staff may attend the following Midwest ISO-related meetings...] November 17 [cir] December 1 Midwest ISO Informational Forum (3 p.m.-5 p.m., ET) [cir] January 19 [cir...

  2. Análisis descriptivo del impacto de Sistemas de Gestión de Calidad (EFQM e ISO en centros de Educación Primaria de la Comunidad Autónoma Gallega

    Directory of Open Access Journals (Sweden)

    Eva María Espiñeira-Bellón

    2016-01-01

    Full Text Available La necesidad de mejora de los centros educativos a través de la implantación de Sistemas de Gestión de Calidad (SGC, es cada vez más frecuente. Los modelos de gestión de calidad más empleados para ello son la familia de normas UNE-­‐EN-­‐ISO 9000 (ISO 9001 y el modelo de excelencia de la European Foundation for Quality Management (EFQM. El impacto de dichas implantaciones, sin embargo, no es tan abordado, por lo que, el objetivo principal de este trabajo es realizar un análisis descriptivo acerca del impacto percibido por equipos docentes y directivos en 24 instituciones educativas gallegas (35 casos de la etapa de Educación Primaria como consecuencia de la implantación de un SGC. Los resultados indican que, si bien el grado de aplicación del Modelo EFQM es bajo en este tipo de centros, parece ser apropiado para ellos. Los resultados generales son más positivos en los centros en los que se ha implantado la Norma ISO. Mediante el análisis de resultados, se ha podido conocer en qué medida el esfuerzo dedicado a la implantación del modelo EFQM o de la norma ISO 9001 en centros educativos de la etapa de primaria produce realmente los objetivos o resultados esperados.

  3. [Quality assurance in oncology: experiences of an ISO certification].

    Science.gov (United States)

    Szentirmay, Zoltán; Cseh, Lujza; Ottó, Szabolcs; Kásler, Miklós

    2002-01-01

    The ISO 9001 quality assurance of the National Institute of Oncology has been achieved successfully. We give an account of the brief history and the structure of the assurance system of the Institute, the process of setting our goals, and also the experience gained from drafting ISO 9001 handbook and flowcharts. Apart from the bureaucratic nature of quality assurance, it is a good opportunity for us to investigate our everyday work, put it into orderly manner and work more reliably. Experience has shown that the introduction of a quality assurance system increases the level of patient care, the documentation helps the Institute or some of its departments, or even individuals prevent law suits, and serves as a sound basis for proposing promotion, salary increases and bonuses, or even honors.

  4. ENVIRONMENTAL RESPONSIBILITY MODEL BASED ON ISO 14000 MANAGEMENT SYSTEMS

    Directory of Open Access Journals (Sweden)

    Catalina SITNIKOV

    2012-01-01

    Full Text Available Worldwide corporations, as well as their stakeholders, are more conscious of the need for environmental management, SR behaviour, and sustainable growth and development. International Standards are becoming more significant for corporations to work towards common environmental management practices. ISO 14001 is the first and the broadest standard intended at a more responsible approach of corporations and the world’s most acknowledged framework for environmental management systems that assists corporations to better manage the effect of their activities on the environment. This article aims to study ISO 14001 implementation and its effects on the environmental responsibility. A model will be built, which covers the environmental management system, the components of organizational culture, being able to influence environmental standards implementation.

  5. Iso-scaling in a microcanonical multifragmentation model

    International Nuclear Information System (INIS)

    Raduta, R.; Raduta, H.

    2003-01-01

    A microcanonical multifragmentation model is used to investigate iso-scaling over a broad range of excitation energies, for several values of freeze-out volume and equilibrated sources with masses between 40 and 200 in both primary and asymptotic stages of the decay. It was found that the values of the slope parameters α and β depend on the size and excitation energy of the source and are affected by the secondary decay of primary fragments. It was evidenced that iso-scaling is affected by finite size effects. The evolution of the differences of neutron and proton chemical potentials corresponding to two equilibrated nuclear sources having the same size and different isospin values with temperature and freeze-out volume is presented. (authors)

  6. Complementing network security to the ISO/IEC 27000 standard

    OpenAIRE

    Alila, Patrick

    2007-01-01

    I syfte att öppna upp nya affärsmöjligheter för informationssäkerhetsföretaget Secure State AB, har detta arbete bedrivits för att komplettera företagets nuvarande standard för informationssäkerhetsarbete med ytterligare nätverkssäkerhet. Krav på slutresultatet var att dokumentet eller standarden skulle kunna komplettera ISO 27000, samt vara kostnadseffektivt. Efter en undersökning av den nämnda standarden konstaterades att enbart ISO 27000 i sig inte är ett fullgott verktyg för nätverkssäker...

  7. Composite repairs qualification according to ISO/TS 24817

    Energy Technology Data Exchange (ETDEWEB)

    Meniconi, Luiz C.M.; Perrut, Valber A. [Petroleo Brasileiro S.A. (PETROBRAS/CENPES), Rio de Janeiro, RJ (Brazil). Centro de Pesquisas

    2009-07-01

    Composite repairs for metallic pipes from three different suppliers were evaluated according to ISO Technical Specification TS 24817. The intended application scenarios are offshore production plants, but the design methodology is also applicable to onshore pipelines and pipework. The evaluation covered all the relevant mechanical properties and established the maximum application temperatures for each repair system. The tests also considered the application of composite repair sleeves to metallic pipes with through thickness defects, by measuring the strain energy release rates of the composite-metal interfaces. The test campaigns aimed to verify the applicability of the recently published ISO document, and to implement it as the routine procedure for composite repairs evaluation within PETROBRAS. The tests also addressed the influence of metallic pipe surface preparation on the final properties of the repair sleeves, especially in relation to the long term behavior of leaking pipes repaired by means of composite materials. (author)

  8. Comparison between ASHRAE and ISO thermal transmittance calculation methods

    DEFF Research Database (Denmark)

    Blanusa, Petar; Goss, William P.; Roth, Hartwig

    2007-01-01

    is proportional to the glazing/frame sightline distance that is also proportional to the total glazing spacer length. An example calculation of the overall heat transfer and thermal transmittance (U-value or U-factor) using the two methods for a thermally broken, aluminum framed slider window is presented....... The fenestration thermal transmittance calculations analyses presented in this paper show that small differences exist between the calculated thermal transmittance values produced by the ISO and ASHRAE methods. The results also show that the overall thermal transmittance difference between the two methodologies...... decreases as the total window area (glazing plus frame) increases. Thus, the resulting difference in thermal transmittance values for the two methods is negligible for larger windows. This paper also shows algebraically that the differences between the ISO and ASHRAE methods turn out to be due to the way...

  9. The development of ISO freight containers as IP-2 packagings

    International Nuclear Information System (INIS)

    Janicki, M.C.; Vaughan, R.A.

    1993-01-01

    Design specifications were developed for ISO freight containers to meet the requirements of the transport regulations in the 1985 Edition of IAEA SS6, and to maximize the technical and commercial benefits offered to consignors by this type of container for the transport and handling of bulk LSA/SCO materials. A range of IP-2 ISO freight containers have been designed and built to these specifications and are in use in the UK. This paper discusses the regulatory considerations which had to be reviewed and interpreted in developing freight containers as Industrial Package Type 2 (IP-2) packagings and the development of performance standards to meet the regulatory requirements. Outline details of the packages developed are indicated together with examples of handling equipment developed to facilitate loading and unloading. (J.P.N.)

  10. Why did ISO 9001:2008 system fail to deliver?

    Science.gov (United States)

    Langford, Melvyn

    2014-02-01

    This article is based on an actual investigation undertaken, and summarises the subsequent report's findings and observations. It has been anonymised for obvious reasons. In May 2013 an analysis was undertaken by a multidisciplinary team that compared an NHS Trust estates department's managerial systems against the NHS national recommendations. The conclusions stated that: 'There was a systemic failure across a large number of topics generating intolerable/substantial risks to the organisation, its staff, and patients; this despite the department's managerial systems being accredited to the International Standard ISO 9001:2008'. The natural question raised when presented with this demonstrable and auditable evidence was: 'Why did the ISO 9001:2008 system fail?'

  11. Quality control with R an ISO standards approach

    CERN Document Server

    Cano, Emilio L; Prieto Corcoba, Mariano

    2015-01-01

    Presenting a practitioner's guide to capabilities and best practices of quality control systems using the R programming language, this volume emphasizes accessibility and ease-of-use through detailed explanations of R code as well as standard statistical methodologies. In the interest of reaching the widest possible audience of quality-control professionals and statisticians, examples throughout are structured to simplify complex equations and data structures, and to demonstrate their applications to quality control processes, such as ISO standards. The volume balances its treatment of key aspects of quality control, statistics, and programming in R, making the text accessible to beginners and expert quality control professionals alike. Several appendices serve as useful references for ISO standards and common tasks performed while applying quality control with R.

  12. Aplicació de normes ISO 9001:2000

    OpenAIRE

    Etminani Moslehi-Tehrani, Houman

    2009-01-01

    Este documento se trata de la implantacion y aplicacion de la norma UNE-EN-ISO 9001:2000 a partir de la politica de la empresa LBS respecto a la calidad, proporcionando elementos para lograr la calidad de los productos y servicios de acuerdo con los requisitos y necesidades del cliente, con el compromiso de asegurar y garantizar permanentemente la calidad de dichos productos y servicios consiguiendo la satisfaccion del cliente. Esta norma define un sistema de gestion de la cali...

  13. ENVIRONMENTAL RESPONSIBILITY MODEL BASED ON ISO 14000 MANAGEMENT SYSTEMS

    OpenAIRE

    Catalina SITNIKOV

    2012-01-01

    Worldwide corporations, as well as their stakeholders, are more conscious of the need for environmental management, SR behaviour, and sustainable growth and development. International Standards are becoming more significant for corporations to work towards common environmental management practices. ISO 14001 is the first and the broadest standard intended at a more responsible approach of corporations and the world’s most acknowledged framework for environmental management systems that assist...

  14. ISO 9000 implementation in a middle-scale Turkish organization

    OpenAIRE

    Uzkan, Ismail Burak

    1996-01-01

    Ankara : The Department of Management and Graduate School of Business Administration of Bilkent Univ., 1996. Thesis (Master's) -- Bilkent University, 1996. Includes bibliographical references leaves 62-63 In organizations of every kind, quality is regarded as a means to an end customer satisfaction in all aspects of a product or service. ISO 9000 Standards aim customer satisfaction in that respect. In this study, a real life case which analyses a middle-scale Turkish firm t...

  15. PROPOSALS FOR THE IMPLEMENTATION AND IMPROVEMENT OF ISO 9001

    OpenAIRE

    Antero Ollila

    2012-01-01

    The ISO 9001 quality management system (QMS) includes a method of continuous improvement put in place in 1994. Through this system, audits and reviews are performed to identify, correct and prevent problems. Although the method of continuous improvement, combined with adherence to annual quality objectives, is an important part of the QMS, only a few business managers and quality professionals seem to acknowledge its significance. Whether the organization uses QMS or other improvement program...

  16. ISOS: A job evaluation system to implement comparable worth

    Directory of Open Access Journals (Sweden)

    Albert Corominas

    2008-01-01

    Full Text Available A fair pay structure is an essential element of the personnel policy of a firm. If the pay structure is perceived as arbitrary by the members of the staff, it becomes a cause of disturbance of the labor relations. Particularly, a pay structure is unfair if it discriminates against women. Job evaluation is a traditional tool used by companies to assist in the process of determining pay structures that can be also useful to detect and combat wage discrimination, since allow determining whether two jobs are of comparable worth or not. Although there are many kinds of systems, authors agree when defining point factor methods as the most appropriate and fair job evaluation systems. However, even being well defined from a technical point of view, most existing systems give discriminatory results regarding to gender. ISOS, a new job evaluation system which is described in this paper, has been designed, with the aim to define a neutral system with regard to gender, based on present jobs characteristics, existing job evaluation systems and job description questionnaires, international experts’ knowledge and a wide body of literature on gender discrimination and its relation with job evaluation. Using ISOS can contribute to detect, combat and eliminate part of the existing wage discrimination in general and, in particular, against women. ISOS includes all aspects of the work so no characteristics are omitted. The system can be applied in any company and to evaluate any job, and offers flexibility to be adapted to the specific characteristics of an organization. ISOS can also be used to detect and combat wage discrimination. Furthermore, characteristics of present jobs, such as cross-training or flexible working time, are also included so the system can be considered innovative in a very traditional field of industrial engineering.

  17. An Utilization Method Cooperating ISO drawings and Bookmarks for NDE

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Hyun-Ju; Cho, Chan-Hee; Lee, Tae-Hun [KHNP Central Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    The inspection of weld parts are performed with various non-destructive test methods such as AUT, VT, PT, ECT, etc. The results have been published in the report booklets. Moreover, huge amount of non-destructive inspection data and reports, which are produced from the '78 Kori 1 to newly constructed power plant, are stored in the management department and DDCC of each power plant. Because the data are not classified, it takes much time to find the corresponding non-destructive test results report of a specific unit of a power plant for a particular year. In addition, it is possibility to make human error because the report is written and submitted after finding manually the non-destructive test results for the concerning weld. When there is a dispute of the results of non-destructive inspection of a particular weld, analyzes the control center, a result of the power plant and the corresponding non-destructive inspection of a particular weld of ISO drawing in many places such as control center, corresponding power plant and CRI was discussed together will be to derive the final conclusion. For discussion, the person in charge of each site, looking for ISO drawings there is a result of the weld, in the past results history report of non-destructive testing for this, by searching the results of the welding site, telephone and E-mail disadvantage of complicated procedures if necessary to the discussion together in -mail is performed I have. In this paper, we describe the contents introduced the ISO drawings and Bookmark function is trying to complement these drawbacks. By applying the present invention utilization, find the ISO drawings manually when querying the results of the non-destructive inspection of past weld, which reduces the time to grasp the content of the non-destructive test results report.

  18. Automotive standard ISO/TS 16949 as a quality determinant

    Directory of Open Access Journals (Sweden)

    Joanna Rosak-Szyrocka

    2016-03-01

    Full Text Available The main aim of this paper is to present the standard ISO/TS 16949. In the modern world of competition, quality is one of the most important factors. Modern organizations should gamble on quality, regardless of the type of business, because it is the basic form of running a business effectively. It is not only a factor of market success, but also an indication of organizational culture.

  19. Di-iso-Butyl Phthalate MATERNAL AND FETAL DATA FROM ...

    Science.gov (United States)

    this file contains the raw data on the effects of in utero administration of di-iso-butyl phthalate on maternal weight gain during dosing and the numbers of fetuses and fetal resorptions. The data have all been previously published, as described on the file metadata sheet. Raw data file from our published studies on DIBP specifically requested (6/14/2016) by NCEA scientists for analysis and inclusion in their assessment of this chemical.

  20. Biomedical potential of chitosan/HA and chitosan/β-1,3-glucan/HA biomaterials as scaffolds for bone regeneration — A comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Przekora, Agata, E-mail: agata.przekora@umlub.pl [Department of Biochemistry and Biotechnology, Medical University of Lublin, Chodzki 1, 20-093 Lublin (Poland); Palka, Krzysztof [Department of Materials Engineering, Lublin University of Technology, Nadbystrzycka 36, 20-618 Lublin (Poland); Ginalska, Grazyna [Department of Biochemistry and Biotechnology, Medical University of Lublin, Chodzki 1, 20-093 Lublin (Poland)

    2016-01-01

    The aim of this work was to compare biomedical potential of chitosan/hydroxyapatite (chit/HA) and novel chitosan/β-1,3-glucan/hydroxyapatite (chit/glu/HA) materials as scaffolds for bone regeneration via characterization of their biocompatibility, porosity, mechanical properties, and water uptake behaviour. Biocompatibility of the scaffolds was assessed in direct-contact with the materials using normal human foetal osteoblast cell line. Cytotoxicity and osteoblast proliferation rate were evaluated. Porosity was assessed using computed microtomography analysis and mechanical properties were determined by compression testing. Obtained results demonstrated that chit/HA scaffold possessed significantly better mechanical properties (compressive strength: 1.23 MPa, Young's modulus: 0.46 MPa) than chit/glu/HA material (compressive strength: 0.26 MPa, Young's modulus: 0.25 MPa). However, addition of bacterial β-1,3-glucan to the chit/HA scaffold improved its flexibility and porosity. Moreover, chit/glu/HA scaffold revealed significantly higher water uptake capability (52.6% after 24 h of soaking) compared to the chit/HA (30.7%) and thus can serve as a very good drug delivery carrier. Chit/glu/HA scaffold was also more favourable to osteoblast survival (near 100% viability after 24-h culture), proliferation, and spreading compared to the chit/HA (63% viability). The chit/glu/HA possesses better biomedical potential than chit/HA scaffold. Nevertheless, poor mechanical properties of the chit/glu/HA limit its application to non-load bearing implantation area. - Highlights: • Chitosan/HA and chit/β-1,3-glucan/HA scaffolds for bone regeneration were compared. • Chit/HA significantly reduced osteoblast viability to 63% compared to chit/glu/HA. • Unlike chit/HA, chit/glu/HA favoured cell adhesion, spreading, and proliferation. • Chit/HA had better compressive strength and Young's modulus than chit/glu/HA. • Chit/glu/HA revealed significantly higher

  1. Thirty years of international nuclear standards in ISO and IEC

    International Nuclear Information System (INIS)

    Becker, K.

    1991-01-01

    Of over 4700 nuclear and radiation protection standards, laws, regulations, recommendations, etc., which have been issued by 52 countries and several governmental international organizations such as IAEA, or non-government organizations such as ICRP, ICRU, ISO and IEC, more than 90% are national, and more than half of those of a non-regulatory nature. Both number and importance of international standards are, however, increasing. The two most important non-governmental international standards organizations are the International Organization for Standardization (ISO), which founded a Technical Committee (TC) 85 'Nuclear Energy' with several Sub-Committees in 1957, and the closely associated International Electrotechnical Commission (IEC) with its TC 45 'Nuclear Instrumentation' formed in 1960. There are over 20 member countries actively participating in the work in each of them, with additional observer countries and liaison to the relevant other international organizations. A brief review is given on some of the experience which has been gained by ISO/TC 85 and IEC/TC 45, and its work program and accomplishments, considering in particular recent developments. It covers nuclear safety and instrumentation, radiation protection, and the nuclear fuel cycle, as well as interface issues including definitions and terminology, interaction of the activities with the work of other national and international bodies, etc. Some problem areas are also briefly discussed. (orig.)

  2. Implementation of ISO 17025 in the Eletronuclear Environmental Monitoring Laboratory

    International Nuclear Information System (INIS)

    Baliza, Ana Rosa; Caetano, Carla de Brito

    2017-01-01

    In order to grant Angra 3 power plant operation license, the Brazilian Institute for the Environment and Renewable Natural Resources (IBAMA), in the IBAMA Installation License 591/2009 condition 2.24, required that Eletronuclear has to obtain the Environmental Monitoring Laboratory accreditation, in accordance with the requirements of NBR ISO / IEC 17025 standard. The accreditation is the formal recognition that a laboratory has a quality assurance system and technical competence to perform specific tests, evaluated according to the criteria based on NBR ISO/IEC 17025 (General requirements for testing and calibration laboratories competence) standard. In Brazil, the General Accreditation Coordination (CGCRE), according to the guidelines already explained by the Brazilian System of Conformity Assessment (INMETRO), does accreditation. The INMETRO is the only official accrediting body in Brazil and internationally recognized by the International Accreditation Forum (IAF). The Environmental Monitoring Laboratory at Eletronuclear is an analytical laboratory of chemical, radiochemical and biological tests, which analyzes several matrices, such as seawater, river water, marine sediment, beach sand, soil, pasture, banana, milk, besides marine sea life, around the Central Almirante Álvaro Alberto power plant station. It is licensed by CNEN, INEA, IBAMA and it follows national and international standards in the performance of the tests as well as in the collection and preparation of samples. This article describes the main steps that the Eletronuclear Environmental Monitoring Laboratory followed to implement ISO 17025. (author)

  3. Implementation of ISO 17025 in the Eletronuclear Environmental Monitoring Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Baliza, Ana Rosa; Caetano, Carla de Brito, E-mail: baliza@eletronuclear.gov.br [Eletrobrás Termonuclear S.A. (ELETRONUCLEAR), Angra dos Reis, RJ (Brazil)

    2017-07-01

    In order to grant Angra 3 power plant operation license, the Brazilian Institute for the Environment and Renewable Natural Resources (IBAMA), in the IBAMA Installation License 591/2009 condition 2.24, required that Eletronuclear has to obtain the Environmental Monitoring Laboratory accreditation, in accordance with the requirements of NBR ISO / IEC 17025 standard. The accreditation is the formal recognition that a laboratory has a quality assurance system and technical competence to perform specific tests, evaluated according to the criteria based on NBR ISO/IEC 17025 (General requirements for testing and calibration laboratories competence) standard. In Brazil, the General Accreditation Coordination (CGCRE), according to the guidelines already explained by the Brazilian System of Conformity Assessment (INMETRO), does accreditation. The INMETRO is the only official accrediting body in Brazil and internationally recognized by the International Accreditation Forum (IAF). The Environmental Monitoring Laboratory at Eletronuclear is an analytical laboratory of chemical, radiochemical and biological tests, which analyzes several matrices, such as seawater, river water, marine sediment, beach sand, soil, pasture, banana, milk, besides marine sea life, around the Central Almirante Álvaro Alberto power plant station. It is licensed by CNEN, INEA, IBAMA and it follows national and international standards in the performance of the tests as well as in the collection and preparation of samples. This article describes the main steps that the Eletronuclear Environmental Monitoring Laboratory followed to implement ISO 17025. (author)

  4. Strategy for infrared photometry of comets with ISO

    Science.gov (United States)

    Solc, M.; Vanysek, V.; Gruen, E.

    1994-07-01

    The launch of the ISO (Infrared Satellite Observatory) by the European Space Agency is scheduled for autumn 1995. Photometry and spectrophotometry observing programs of comets in the wavelength range 2.5-200 microns for the onboard spectrophotometer ISOPHOT is now under final preparation. Technical details for preparing propasals are given. Phenomena in comets to be studied are surface properties of bare cometary nuclei at large heliocentric distances, onset of coma activity, and coma dust and gas emission (in inner solar system). Dust production, dust/gas mass ratio, dust distribution in coma, and their temporal variability are important for understanding the physical processes on nuclei, and spectrophotometry in the range of 2.5-12 microns could provide us with data of the chemical composition of cometary dust. Several active comets expected for the 18-month lifetime of ISO in 1995-1997 were selected for the ISO Central Program according to their orbital and physical parameters: P/Schwassman-Wachmann 1, P/Encke, P/d'Arrest, P/Honda-Mrkos-Pajdusakova, P/Churyumov-Gerasimenko, P/Kopff, P/IRAS, P/Wirtanen, P/Wild 2, P/Grigg-Skjellerup, P/Schwassman-Wachmann 3, P/Machholz, and (2060) Chiron. Four of them match well various constraints put on the observations by the technical arrangement of the satellite and instrument. A simple four-parameter model (size, albedo, rotation, optical thickness)was developed to estimate the temperatures and thermal fluxes of both solid nuclei and dust coma.

  5. ISO training program mixes lectures, hands-on exercises

    International Nuclear Information System (INIS)

    Sakofsky, S.; Vitale, D.

    1994-01-01

    Early in 1990, the Dresser-Rand Co., made the decision to upgrade its purchased material quality program and pursue ISO 9000 registration for all product divisions. A joint quality-purchasing council from all US based divisions met and developed a new strategy that included: developing and maintaining a common external audit schedule eliminating duplicate audits; development of a formal training program for auditors; implementing a rule for all divisions that called for internal and external audits to be conducted by certified auditors; implementing an aggressive internal audit program for each division preparing for ISO 9001 or 9002 registration. Development of a formal training program began with educating and training future instructors. Two people were selected who had previous audit and quality system experience. Both were sent to various seminars on ISO 9000, attended a lead assessor course, passed the examination, and became registered with the Institute of Quality Assurance (IQA) in the United Kingdom. The original course was developed by a consultant along with one future instructor. Course content used traditional auditing methodology, but included many team exercises including an actual factory audit. The paper describes the methods and contents of this training course

  6. Sensorless adaptive optics for isoSTED nanoscopy

    Science.gov (United States)

    Antonello, Jacopo; Hao, Xiang; Allgeyer, Edward S.; Bewersdorf, Joerg; Rittscher, Jens; Booth, Martin J.

    2018-02-01

    The presence of aberrations is a major concern when using fluorescence microscopy to image deep inside tissue. Aberrations due to refractive index mismatch and heterogeneity of the specimen under investigation cause severe reduction in the amount of fluorescence emission that is collected by the microscope. Furthermore, aberrations adversely affect the resolution, leading to loss of fine detail in the acquired images. These phenomena are particularly troublesome for super-resolution microscopy techniques such as isotropic stimulated-emission-depletion microscopy (isoSTED), which relies on accurate control of the shape and co-alignment of multiple excitation and depletion foci to operate as expected and to achieve the super-resolution effect. Aberrations can be suppressed by implementing sensorless adaptive optics techniques, whereby aberration correction is achieved by maximising a certain image quality metric. In confocal microscopy for example, one can employ the total image brightness as an image quality metric. Aberration correction is subsequently achieved by iteratively changing the settings of a wavefront corrector device until the metric is maximised. This simplistic approach has limited applicability to isoSTED microscopy where, due to the complex interplay between the excitation and depletion foci, maximising the total image brightness can lead to introducing aberrations in the depletion foci. In this work we first consider the effects that different aberration modes have on isoSTED microscopes. We then propose an iterative, wavelet-based aberration correction algorithm and evaluate its benefits.

  7. On the new ISO guide on risk management terminology

    International Nuclear Information System (INIS)

    Aven, Terje

    2011-01-01

    A new ISO guide on risk management terminology has recently been issued. The guide provides basic vocabulary for developing a common understanding of risk assessment and risk management concepts and terms among organisations and functions, and across different application areas. It provides the foundation of, for example, the ISO 31000 standard on risk management. The guide strongly influences the risk assessment and risk management field, and its quality is thus of utmost importance. In this paper a critical review of the guide is conducted. We argue that the guide fails in several ways in producing consistent and meaningful definitions of many of the key concepts covered. A main focus is placed on the risk concept, which is defined as the effect of uncertainty on objectives, but also many other definitions are looked into, including probability, vulnerability, hazard, risk identification and risk description. Examples are used to illustrate the problems and show how they can be rectified. Although the focus is on the ISO guide, the discussion is to a large extent general. The overall aim of the paper is to contribute to the further development of the area of risk assessment and risk management by strengthening its conceptual basis.

  8. [ISO 9001 conformity in research, teaching and rehabilitation].

    Science.gov (United States)

    Howorka, K; Kletschka, G; Pumprla, J; Thoma, H

    1998-01-01

    Quality assurance, in particular in the areas of development and production of medical devices, is one of the tasks of biomedical engineering. The interdisciplinary working group "Functional Rehabilitation and Group Education, Vienna" is committed to the development and implementation of group education models on three levels: (1) direct education/instruction of patients with chronic diseases, (2) university research and teaching, and (3) development of technical aids for rehabilitation and the means for disseminating group education models in rehabilitation and therapy. Major aims were, by generating conformity with ISO 9001 standards, to achieve greater transparency and process optimization with very small resources in university (teaching, research, technical aids) and extra-university (rehabilitation) areas. A secondary aim was the establishment of interdisciplinary (clinical and biomedical) cooperation at university level. In all main areas (research, teaching and group education/instruction), ISO 9001-conformity was achieved by our activities on three methodological levels: (1) description and analysis of processes, (2) use of ISO 9001 standards for evaluating internal processes, and (3) optimization measures. The following article contains relevant elements of the quality manual and quality assurance system, and offers a typical example of innovative cooperation between medicine and medical engineering.

  9. Auditoría de seguridad informática ISO 27001 para la empresa de alimentos Italimentos Cía. Ltda.

    OpenAIRE

    Cadme Ruiz, Christian Miguel; Duque Pozo, Diego Fabián

    2011-01-01

    En la empresa de Italimentos existe ciertas vulnerabilidades para acceder a cierta información, para ello se ha realizado una auditoria de seguridad informática basada en un estándar internacional ISO 27001, anexo A, el cual tiene como objetivo la confidencialidad, integridad e integridad de los datos. Para ello se realizaron ciertos capítulos que ayudaron a encontrar falencias en la seguridad de la información. Para lo cual, se describe a la empresa, producción, comercialización, emplea...

  10. Vocational High School Effectiveness Standard ISO 9001: 2008 for Achievement Content Standards, Standard Process and Competency Standards Graduates

    Directory of Open Access Journals (Sweden)

    Yeni Ratih Pratiwi

    2014-06-01

    Full Text Available Efektivitas Sekolah Menengah Kejuruan Berstandar ISO 9001:2008 terhadap Pencapaian Standar Isi, Standar Proses dan Standar Kompetensi Lulusan Abstract: The purpose of this study was to determine differences in the effectiveness of the achievement of the content standards, process standards, and competency standards in vocational already standard ISO 9001: 2008 with CMS that has not been standardized ISO 9001: 2008 both in public schools and private schools. Data collection using the questionnaire enclosed Likert scale models. Analysis of data using one-way ANOVA using SPSS. The results showed: (1 there is no difference in effectiveness between public SMK ISO standard ISO standards with private SMK (P = 0.001; (2 there are differences in the effectiveness of public SMK SMK ISO standards with ISO standards have not (P = 0.000; (3 there are differences in the effectiveness of public SMK ISO standards with private vocational yet ISO standards (P = 0.000; (4 there are differences in the effectiveness of the private vocational school with vocational standard ISO standard ISO country has not (P = 0.015; (5 there are differences in the effectiveness of the private vocational bertandar ISO with private vocational yet standardized ISO (P = 0.000; (6 there was no difference in the effectiveness of public SMK has not been standardized by the ISO standard ISO private SMK yet. Key Words: vocational high school standards ISO 9001: 2008, the standard content, process standards, competency standards Abstrak: Tujuan penelitian ini untuk mengetahui perbedaan efektivitas pencapaian standar isi, standar proses, dan standar kompetensi lulusan pada SMK yang sudah berstandar ISO 9001:2008 dengan SMK yang belum berstandar ISO 9001:2008 baik pada sekolah negeri maupun sekolah swasta. Pengumpulan data menggunakan kuisioner tertutup model skala likert. Analisis data menggunakan ANOVA one way menggunakan program SPSS. Hasil penelitian menunjukkan: (1 ada perbedaan

  11. Bør leger ha reservasjonsrett ved assistert befruktning?

    Directory of Open Access Journals (Sweden)

    Morten Magelssen

    2011-10-01

    Full Text Available Omfanget av helsepersonells reservasjonsrett har nylig vært gjenstand for debatt i Norge. Vi spør om leger bør ha reservasjonsrett ved utførelse og henvisning til assistert befruktning, og drøfter argumenter for og imot ved hjelp av et rammeverk med sju kriterier for vurdering av reservasjon. Reservasjonsrettens grunnleggende dilemma er hvordan to viktige hensyn, henholdsvis pasientens rett til behandling og hensynet til helsepersonellets moralske integritet, best kan ivaretas. Det argumenteres for at leger bør ha rett til å reservere seg mot å utføre, assistere ved og henvise til assistert befruktning generelt hvis begrunnelsen er hensynet til befruktede eggs moralske verdi. Videre finner vi at leger også kan ha en moralsk rett til reservasjon mot å utføre, assistere ved og henvise til assistert befruktning for likekjønnede, men da på nærmere spesifiserte vilkår.Nøkkelord: reservasjonsrett, assistert befruktning, samvittighet, moralsk integritetEnglish summary: Should physicians have the right to conscientiously object to assisted reproduction?The extent of the healthcare worker's right to conscientious objection has recently been debated in Norway. This article asks whether physicians should have a right to conscientious objection to the performance of, and referral for, assisted reproduction, and discusses arguments for and against the same, utilizing a framework of seven criteria for the evaluation of conscientious objection. The fundamental dilemma of conscientious objection is how two important considerations can be reconciled: the patient's right to treatment, and the protection of the healthcare worker's moral integrity. It is argued that physicians should have the right to object to performing, assisting with, and referring for assisted reproduction generally when the objection is grounded in the moral value of the embryo. Furthermore, physicians may also have a moral right to object to performing, assisting with, and

  12. Immunomodulatory Effects of Hemagglutinin- (HA- Modified A20 B-Cell Lymphoma Expanded as a Brain Tumor on Adoptively Transferred HA-Specific CD4+ T Cells

    Directory of Open Access Journals (Sweden)

    Valentin P. Shichkin

    2014-01-01

    Full Text Available Previously, the mouse A20 B-cell lymphoma engineered to express hemagglutinin (HA antigen (A20HA was used as a systemic tumor model. In this work, we used the A20HA cells as a brain tumor. HA-specific CD4+ T cells were transferred intravenously in a tail vein 5 days after A20HA intracranial inoculation and analyzed on days 2, 9, and 16 after the adoptive transfer by different methods. The transferred cells demonstrated state of activation as early as day 2 after the adoptive transfer and most the of viable HA-specific cells became anergic on day 16. Additionally, symptoms of systemic immunosuppression were observed in mice with massive brain tumors at a late stage of the brain tumor progression (days 20–24 after the A20HA inoculation. Despite that, a deal of HA-specific CD4+ T cells kept the functional activity even at the late stage of A20HA tumor growth. The activated HA-specific CD4+ T cells were found also in the brain of brain-tumor-bearing mice. These cells were still responding to reactivation with HA-peptide in vitro. Our data support an idea about sufficient role of both the tumor-specific and -nonspecific mechanisms inducing immunosuppression in cancer patients.

  13. Avoimen lähdekoodin HA-tietokannat

    OpenAIRE

    Vartio, Sami

    2014-01-01

    Insinöörityössä perehdyttiin avoimen lähdekoodin periaatteisiin ja lisenssimalleihin sekä huomioitiin liiketaloudelliset lähtökohdat. Tavoitteena oli tutustua järjestelmän saatavuuteen sekä klusteroinnin periaatteisiin. Järjestelmän saatavuus (HA) on tietojärjestelmien suunnittelussa käytettävä käytäntö, joka pyrkii siihen että järjestelmä on aina käyttäjän käytettävissä. Aluksi käsiteltiin perustietoja sekä teoriaa. Tutkimuksen edetessä paneuduttiin laajemmin yleisimpiin avoimen lähdeko...

  14. Haïti-Quisqueya: une double insularité

    Directory of Open Access Journals (Sweden)

    Jean-Marie THÉODAT

    1998-09-01

    Full Text Available Deux pays se partagent une île coupée par une frontière méridienne de plus de 300 km: Haïti à l'ouest, Quisqueya à l'est. Cette coupure est l'héritage du partage colonial de l'île entre la France et l'Espagne, et le résultat de la dynamique spatiale contrastée des deux nations qui y sont nées et qui ont eu recours à des principes d'encadrement distincts.De là un sentiment de double insularité, chaque pays se comportant vis-à-vis de son voisin comme s'ils étaient situés sur deux îles séparées.

  15. A practical synthesis of long-chain iso-fatty acids (iso-C12–C19 and related natural products

    Directory of Open Access Journals (Sweden)

    Mark B. Richardson

    2013-09-01

    Full Text Available A gram-scale synthesis of terminally-branched iso-fatty acids (iso-C12–C19 was developed commencing with methyl undec-10-enoate (methyl undecylenate (for iso-C12–C14 or the C15 and C16 lactones pentadecanolide (for iso-C15–C17 and hexadecanolide (for iso-C18–C19. Central to the approaches outlined is the two-step construction of the terminal isopropyl group through addition of methylmagnesium bromide to the ester/lactones and selective reduction of the resulting tertiary alcohols. Thus, the C12, C17 and C18 iso-fatty acids were obtained in three steps from commercially-available starting materials, and the remaining C13–C16 and C19 iso-fatty acids were prepared by homologation or recursive dehomologations of these fatty acids or through intercepting appropriate intermediates. Highlighting the synthetic potential of the iso-fatty acids and various intermediates prepared herein, we describe the synthesis of the natural products (S-2,15-dimethylpalmitic acid, (S-2-hydroxy-15-methylpalmitic acid, and 2-oxo-14-methylpentadecane.

  16. Implantació de la UNE-EN ISO 22716 en una planta d'envasats de cosmètics.

    OpenAIRE

    Cantarell Bernadó, Arnau

    2014-01-01

    Aquest projecte consisteix en la implementació de la Norma ISO 22716 de Bones Pràctiques Cosmètiques a la secció d’envasat de la nostra planta de producció. S’ha començat per fer una primera inspecció en cadascuna de les zones que interactuen en el procés d’envasat, i a partir d’aquí s’han fet una sèrie de propostes de millora segons el text original de la Norma. S’ha previst la implementació de totes les mesures correctores proposades, tant a nivell de procés com a nivell d...

  17. Crystal structure of the HA3 subcomponent of Clostridium botulinum type C progenitor toxin.

    Science.gov (United States)

    Nakamura, Toshio; Kotani, Mao; Tonozuka, Takashi; Ide, Azusa; Oguma, Keiji; Nishikawa, Atsushi

    2009-01-30

    The Clostridium botulinum type C 16S progenitor toxin contains a neurotoxin and several nontoxic components, designated nontoxic nonhemagglutinin (HA), HA1 (HA-33), HA2 (HA-17), HA3a (HA-22-23), and HA3b (HA-53). The HA3b subcomponent seems to play an important role cooperatively with HA1 in the internalization of the toxin by gastrointestinal epithelial cells via binding of these subcomponents to specific oligosaccharides. In this study, we investigated the sugar-binding specificity of the HA3b subcomponent using recombinant protein fused to glutathione S-transferase and determined the three-dimensional structure of the HA3a-HA3b complex based on X-ray crystallography. The crystal structure was determined at a resolution of 2.6 A. HA3b contains three domains, domains I to III, and the structure of domain I resembles HA3a. In crystal packing, three HA3a-HA3b molecules are assembled to form a three-leaved propeller-like structure. The three HA3b domain I and three HA3a alternate, forming a trimer of dimers. In a database search, no proteins with high structural homology to any of the domains (Z score >10) were found. Especially, HA3a and HA3b domain I, mainly composed of beta-sheets, reveal a unique fold. In binding assays, HA3b bound sialic acid with high affinity, but did not bind galactose, N-acetylgalactosamine, or N-acetylglucosamine. The electron density of liganded N-acetylneuraminic acid was determined by crystal soaking. In the sugar-complex structure, the N-acetylneuraminic acid-binding site was located in the cleft formed between domains II and III of HA3b. This report provides the first determination of the three-dimensional structure of the HA3a-HA3b complex and its sialic acid binding site. Our results will provide useful information for elucidating the mechanism of assembly of the C16S toxin and for understanding the interactions with oligosaccharides on epithelial cells and internalization of the botulinum toxin complex.

  18. Characterization, Corrosion Resistance, and Cell Response of High-Velocity Flame-Sprayed HA and HA/TiO2 Coatings on 316L SS

    Science.gov (United States)

    Singh, Tejinder Pal; Singh, Harpreet; Singh, Hazoor

    2012-09-01

    The main aim of this study is to evaluate corrosion and biocompatibility behavior of thermal spray hydroxyapatite (HA) and hydroxyapatite/titania bond (HA/TiO2)-coated 316L stainless steel (316L SS). In HA/TiO2 coatings, TiO2 was used as a bond coat between HA top coat and 316L SS substrate. The coatings were characterized by x-ray diffraction and scanning electron microscopy/energy dispersive spectroscopy, and corrosion resistance determined for the uncoated substrate and the two coatings. The biological behavior was investigated by the cell culture studies using osteosarcoma cell line KHOS-NP (R-970-5). The corrosion resistance of the steel was found to increase after the deposition of the HA and HA/TiO2 bond coatings. Both HA, as well as, HA/TiO2 coatings exhibit excellent bond strength of 49 and 47 MPa, respectively. The cell culture studies showed that HA-coated 316L SS specimens appeared more biocompatible than the uncoated and HA/TiO2-coated 316L SS specimens.

  19. Plasma 8-iso-Prostaglandin F2α, a possible prognostic marker in aneurysmal subarachnoid hemorrhage.

    Science.gov (United States)

    Pan, De-Sheng; Yan, Min; Hassan, Muhammad; Fang, Ze-Bin; Chen, Man-Tao

    2017-06-01

    8-iso-Prostaglandin F2α (8-iso-PGF2α) is a potential biomarker of oxidative stress. This study clarified whether plasma 8-iso-PGF2α concentrations were affected and its underlying relevance to prognosis in aneurysmal subarachnoid hemorrhage (aSAH). In this prospective, observational study, a total of 170 controls and 170 aSAH patients were enrolled. Plasma 8-iso-PGF2α concentrations were detected using an ELISA. Severity was assessed by World Federation of Neurological Surgeons (WFNS) scale and modified Fisher grading scale. Clinical outcomes included 6-month mortality and poor outcome referred to as Glasgow outcome scale score of 1-3. As compared to controls, admission plasma 8-iso-PGF2α concentrations were significantly enhanced. Increased concentrations of plasma 8-iso-PGF2α correlated with WFNS scores and modified Fisher scores. 8-iso-PGF2α in plasma was an independent predictor for clinical outcomes. Under ROC curve, the predictive values of 8-iso-PGF2α concentrations resembled those of WFNS scores and modified Fisher scores for clinical outcomes. An elevation in plasma 8-iso-PGF2α concentrations is associated with the severity and poor outcome after aSAH, substantializing 8-iso-PGF2α as a potential prognostic biomarker of aSAH. Copyright © 2017. Published by Elsevier B.V.

  20. Synthesis and Biological Activity of 2',3'-iso-Aryl-abscisic Acid Analogs.

    Science.gov (United States)

    Wan, Chuan; Wang, Mingan; Yang, Dongyan; Han, Xiaoqiang; Che, Chuanliang; Ding, Shanshan; Xiao, Yumei; Qin, Zhaohai

    2017-12-15

    2',3'- iso -Benzoabscisic acid ( iso -PhABA), an excellent selective abscisic acid (ABA) analog, was developed in our previous work. In order to find its more structure-activity information, some structural modifications were completed in this paper, including the substitution of phenyl ring and replacing the ring with heterocycles. Thus, 16 novel analogs of iso -PhABA were synthesized and screened with three bioassays, Arabidopsis and lettuce seed germination and rice seedling elongation. Some of them, i.e., 2',3'- iso -pyridoabscisic acid ( iso -PyABA) and 2',3'- iso -franoabscisic acid ( iso -FrABA), displayed good bioactivities that closed to iso -PhABA and natural (+)-ABA. Some others, for instance, substituted- iso -PhABA, exhibited certain selectivity to different physiological process when compared to iso -PhABA or (+)-ABA. These analogs not only provided new candidates of ABA-like synthetic plant growth regulators (PGRs) for practical application, but also new potential selective agonist/antagonist for probing the specific function of ABA receptors.

  1. Implementation of ISO guide 25 in a medical dosimetry secondary standards calibration laboratory

    International Nuclear Information System (INIS)

    DeWerd, L.A.

    1995-01-01

    Currently, there is a great deal of discussion among industry and government agencies about ISO 9000 accreditation. U.S. manufacturers with ISO 9000 accreditation are regarded more favorably by European countries. The principles behind the ISO 9000 accreditation are based on the Total Quality Management (TQM) principles that are being implemented in many U.S. industries. This paper will deal only with the calibration issue. There is a difference in the areas covered by ISO 9000 and ISO Guide 25 documents. ISO 9000, in particular ISO 9001 - ISO 9003, cover the open-quotes calibrationclose quotes of inspection, measuring and test equipment. This equipment is basically used for open-quotes factory calibrationsclose quotes to determine that equipment is performing within manufacturer specifications. ISO Guide 25 is specifically for open-quotes calibration and testing laboratories,close quotes generally laboratories that have painstaking procedures to reduce uncertainties and establish high accuracy of the transfer of calibration. The experience of the University of Wisconsin Accredited Dosimetry Calibration Laboratory in conforming to ISO Guide 25 will be outlined. The entire laboratory staff must become familiar with the process and an individual with direct authority must become the one to maintain the quality of equipment and calibrations in the role of open-quotes quality-assurance manager.close quotes

  2. Elaboración de la documentación necesaria para la implantación de un sistema de gestión de la calidad ISO 9001:2000 en una empresa de inyección de plásticos

    OpenAIRE

    Fort Viader, Federico

    2008-01-01

    El objetivo del proyecto es la elaboración de la documentación necearia para la implantación de un sistema de gestión de la calidad ISO 9001:2000 en una empresa de inyección de plásticos. Dentro de este proyecto se ha confeccionado: el Manual de Gestión de la Calidad basado en ISO 9001:2000, las Fichas de Proceso y el Manual de Procedimientos. Una vez finalizado el proyecto, se ha conseguido terminar con éxito la elaboración de dicha documentación, con lo que la empresa ha conseguido ...

  3. Re-engineering caused by ISO-9000 certification

    DEFF Research Database (Denmark)

    Hvam, Lars; Nielsen, Anders Paarup; Bjarnø, Ole-Christian

    1997-01-01

    Based on a project performed at a medium-sized producer of medical utensils, reviews some of the problems which the company experienced in connection with the system built up during ISO 9001 certification, and the re-engineering efforts which were performed in order to relieve these problems....... Focuses in particular on a re-structuring of the company’s system for production documentation and its relation to the traceability of their products. This system was radically altered during the project without the traceability requirements being violated or reduced. These changes resulted in a marked...... increase in productivity....

  4. New guideline represents 'processed-oriented' approach for ISO 9000.

    Science.gov (United States)

    2001-02-01

    Hospitals that have been tracking the development of ISO 9000 in the health care industry should pay close attention to a new guideline about to emerge. According to Laura Preole, health care services manager of SGS International Certification Services based in Rutherford, NJ, the new guideline is the latest step in an effort to establish a more 'process-oriented' method of looking at the health care environment from the moment a patient walks into a facility to the moment he or she is discharged.

  5. Arranging ISO 13606 archetypes into a knowledge base.

    Science.gov (United States)

    Kopanitsa, Georgy

    2014-01-01

    To enable the efficient reuse of standard based medical data we propose to develop a higher level information model that will complement the archetype model of ISO 13606. This model will make use of the relationships that are specified in UML to connect medical archetypes into a knowledge base within a repository. UML connectors were analyzed for their ability to be applied in the implementation of a higher level model that will establish relationships between archetypes. An information model was developed using XML Schema notation. The model allows linking different archetypes of one repository into a knowledge base. Presently it supports several relationships and will be advanced in future.

  6. Communication - An Effective Tool for Implementing ISO 14001/EMS

    Energy Technology Data Exchange (ETDEWEB)

    Rachel Damewood; Bowen Huntsman

    2004-04-01

    The Idaho National Engineering and Environmental Laboratory (INEEL) received ISO 14001/EMS certification in June 2002. Communication played an effective role in implementing ISO 14001/EMS at the INEEL. This paper describes communication strategies used during the implementation and certification processes. The INEEL achieved Integrated Safety Management System (ISMS) and Voluntary Protection Program (VPP) Star status in 2001. ISMS implemented a formal process to plan and execute work. VPP facilitated worker involvement by establishing geographic units at various facilities with employee points of contact and management champions. The INEEL Environmental Management System (EMS) was developed to integrate the environmental functional area into its ISMS and VPP. Since the core functions of ISMS, VPP, and EMS are interchangeable, they were easy to integrate. Communication is essential to successfully implement an EMS. (According to ISO 14001 requirements, communication interacts with 12 other elements of the requirements.) We developed communication strategies that integrated ISMS, VPP, and EMS. For example, the ISMS, VPP, and EMS Web sites communicated messages to the work force, such as “VPP emphasizes the people side of doing business, ISMS emphasizes the system side of doing business, and EMS emphasizes the systems to protect the environment; but they all define work, identify and analyze hazards, and mitigate the hazards.” As a result of this integration, the work force supported and implemented the EMS. In addition, the INEEL established a cross-functional communication team to assist with implementing the EMS. The team included members from the Training and Communication organizations, VPP office, Pollution Prevention, Employee and Media Relations, a union representative, facility environmental support, and EMS staff. This crossfunctional team used various communication strategies to promote our EMS to all organization levels and successfully implemented EMS

  7. ncISO Facilitating Metadata and Scientific Data Discovery

    Science.gov (United States)

    Neufeld, D.; Habermann, T.

    2011-12-01

    Increasing the usability and availability climate and oceanographic datasets for environmental research requires improved metadata and tools to rapidly locate and access relevant information for an area of interest. Because of the distributed nature of most environmental geospatial data, a common approach is to use catalog services that support queries on metadata harvested from remote map and data services. A key component to effectively using these catalog services is the availability of high quality metadata associated with the underlying data sets. In this presentation, we examine the use of ncISO, and Geoportal as open source tools that can be used to document and facilitate access to ocean and climate data available from Thematic Realtime Environmental Distributed Data Services (THREDDS) data services. Many atmospheric and oceanographic spatial data sets are stored in the Network Common Data Format (netCDF) and served through the Unidata THREDDS Data Server (TDS). NetCDF and THREDDS are becoming increasingly accepted in both the scientific and geographic research communities as demonstrated by the recent adoption of netCDF as an Open Geospatial Consortium (OGC) standard. One important source for ocean and atmospheric based data sets is NOAA's Unified Access Framework (UAF) which serves over 3000 gridded data sets from across NOAA and NOAA-affiliated partners. Due to the large number of datasets, browsing the data holdings to locate data is impractical. Working with Unidata, we have created a new service for the TDS called "ncISO", which allows automatic generation of ISO 19115-2 metadata from attributes and variables in TDS datasets. The ncISO metadata records can be harvested by catalog services such as ESSI-labs GI-Cat catalog service, and ESRI's Geoportal which supports query through a number of services, including OpenSearch and Catalog Services for the Web (CSW). ESRI's Geoportal Server provides a number of user friendly search capabilities for end users

  8. La Ha de la infancia en Italia. Problemas y perspectiva

    Directory of Open Access Journals (Sweden)

    Enzo CATARSI

    2010-03-01

    Full Text Available RESUMEN: La historiografía italiana de la infancia, como la de otros muchos países europeos, está hoy embarcada en una tarea de desarrollo y profundización que permitirá recuperar los retrasos que la han caracterizado. En efecto, también en Italia la historia de la infancia y su individuación como «objeto» historiografía constituyen una adquisición reciente, lograda con la ayuda de diversas influencias. La primera, estrechamente vinculada a la historia de las mentalidades, representada por la obra de Ph. Aries, «El niño y la vida familiar en el Antiguo Régimen», traducido al italiano en 1968. La segunda es la historia social, orientada al estudio de los diversos aspectos de la vida de una sociedad, y más atenta a sus acontecimientos. La tercera la representa el estructuralismo, especialmente el francés, y en concreto M. Foucault. La particular influencia que, también en el contexto italiano, han alcanzado los trabajos de Ph. Aries y L. DeMause, muy importantes por haber abierto una línea de investigación, aunque con las obligadas diferencias, ha conducido a privilegiar una perspectiva exclusiva de historia de las mentalidades que se muestra muy ambigua y claramente interpretativa en exceso.

  9. Prediction of IOI-HA Scores Using Speech Reception Thresholds and Speech Discrimination Scores in Quiet

    DEFF Research Database (Denmark)

    Brännström, K Jonas; Lantz, Johannes; Nielsen, Lars Holme

    2014-01-01

    ), and speech discrimination scores (SDSs) in quiet or in noise are common assessments made prior to hearing aid (HA) fittings. It is not known whether SRT and SDS in quiet relate to HA outcome measured with the International Outcome Inventory for Hearing Aids (IOI-HA). PURPOSE: The aim of the present study...... COLLECTION AND ANALYSIS: The psychometric properties were evaluated and compared to previous studies using the IOI-HA. The associations and differences between the outcome scores and a number of descriptive variables (age, gender, fitted monaurally/binaurally with HA, first-time/experienced HA users, years...

  10. ISO 9000 IMPLEMENTATION AND PERCEIVED ORGANISATIONAL OUTCOME: THE CASE OF A SERVICE ORGANISATION

    Directory of Open Access Journals (Sweden)

    Jasni Abdul Latif

    2003-01-01

    Full Text Available The study examines the relationship between the perceptions of the employees about ISO 9000 implementation and perceived organisational outcomes. A conceptual framework linking the level of employee influence and involvement, their perception of ISO 9000 and the perceived impact on their work and the organisational outcomes is posited. Data was collected from a random sample of 64 employees of a service organisation. Contrary to expectations, the work impact of ISO 9000 was not correlated with the efficiency and market outcomes of ISO 9000 certification but the employee involvement, influence and perception of ISO 9000 were. The conceptualization of the influence path of ISO 9000 implementation on the organisational outcomes may require rethinking as perception may have a direct effect on the outcomes without the mediation of the impact on work. In short, employees may report benefits or positive outcomes even though no change is reported in their work.

  11. ISO 14000 information platform. Quarterly report, January 1--March 31, 1998

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-09-01

    GETE, through its ISO 14000 Information Platform, globeNet{trademark} (www.iso14000.net), seeks to provide FETC and the US Department of Energy (DOE) with a timely, accurate, and reliable information resource on the issue of environmental management standards. This resource allows FETC to keep track of the latest developments in the ISO 14000 arena, in DOE as well as throughout the federal complex and industry. Utilizing this information, FETC and DOE can make critical decisions on their own use and implementation of the ISO 14000 standards. The information platform also provides FETC with a forum to present information on its activities, such as the DOE ISO 14000 Pilot Projects, and as an information gathering and dissemination resource for its publications. GETE works with an array of national and international contacts and content sources to gather information and provide daily updates on ISO 14000 and related environmental management issues.

  12. IMPLEMENTASI SISTEM MANAJEMEN MUTU BERBASIS ISO 9001:2000 PADA SEKOLAH MENENGAH KEJURUAN

    Directory of Open Access Journals (Sweden)

    Mardi Wiyono

    2012-09-01

    Full Text Available Abstract: The implementation of ISO 9001:2000 quality management system in vocational school. The needs of quality products and services is largerly expanded in various organizations including education. Recently, the vocational schools also realize how important the quality product and service is. For achieving the quality product or service, some organizations implement the concept of ISO 9001:2000 quality management system. In 2006/2007 it is reported that there are some vocational schools have been certified with ISO 9001:2000. ISO 9001 is a serial document consists of Quality Management System Standard which has been refised from its previous standard. ISO 9001:2000 gives a number of prerequisites for organizations having business initialized by design and development, production, installations, and services. The vocational schools which have been certified with ISO 9001:2000, have to be re-accredited after three years of implementation.

  13. Using ISO 25040 standard for evaluating electronic health record systems.

    Science.gov (United States)

    Oliveira, Marília; Novaes, Magdala; Vasconcelos, Alexandre

    2013-01-01

    Quality of electronic health record systems (EHR-S) is one of the key points in the discussion about the safe use of this kind of system. It stimulates creation of technical standards and certifications in order to establish the minimum requirements expected for these systems. [1] In other side, EHR-S suppliers need to invest in evaluation of their products to provide systems according to these requirements. This work presents a proposal of use ISO 25040 standard, which focuses on the evaluation of software products, for define a model of evaluation of EHR-S in relation to Brazilian Certification for Electronic Health Record Systems - SBIS-CFM Certification. Proposal instantiates the process described in ISO 25040 standard using the set of requirements that is scope of the Brazilian certification. As first results, this research has produced an evaluation model and a scale for classify an EHR-S about its compliance level in relation to certification. This work in progress is part for the acquisition of the degree of master in Computer Science at the Federal University of Pernambuco.

  14. Analisis Pelaksanaan Sertifikasi ISO 9001 : 2008 Puskesmas Kalasan Kabupaten Sleman

    Directory of Open Access Journals (Sweden)

    Khamidah Yuliati

    2016-07-01

    Full Text Available The background of the study was the implementation of standardization of health service quality stated in ISO 9001: 2008 in Kalasan Health Center effectively applied on July 9th, 2009. It was hoped that the implementation of standardization of basic health service quality increase the quality of health service and human resources. The data collection was conducted by interview and questionnaire, and the collected data were in the form of primary and secondary data. The number of the research sample was 40 respondents. The data analysis method used was descriptive. The conclusions of the research result and analysis were (1 all employees increase the service quality for all patients in Kalasan Health Center. The curative aspect was emphasized on outpatients, and the stabilization of emergency and referral patients. (2 Acknowledging qualified work achievements by giving the opportunity to have position promotion as procedure assigned. Work satisfaction was from the existing of formation facility or space condition that gave comfort feeling. (3 Work team and colleague feeling needed to be maintained so that priority gap got decreased. The coordination between the employer and the employee is useful to finish the work. (4 The institution gave guarantee on health service quality which was as the hope of the consumer (patient and strengthened the competitiveness. Therefore, the implementation of quality management system based on the concept of ISO 9001:2008 as the effort to strengthen the competitiveness was urgent.

  15. DuPont IsoTherming clean fuel technology

    Energy Technology Data Exchange (ETDEWEB)

    Levinski, E. [E.I. DuPont Co., Wilmington, DE (United States)

    2009-07-01

    This poster described a hydroprocessing technology that DuPont has acquired from Process Dynamics, Inc. The IsoTherming clean fuel technology significantly reduces sulphur in motor fuels. The technology provides petroleum refiners the solution for meeting ultra low sulphur diesel requirements, at much lower costs than conventional technologies. IsoTherming hydroprocessing operates in a kinetically limited mode, with no mass transfer limitation. Hydrogen is delivered to the reactor in the liquid phase as soluble hydrogen, allowing for much higher space velocities than conventional hydrotreating reactors. Treated diesel is recycled back to the inlet of the reactor, generating less heat and more hydrogen into the reactor. The process results in a more isothermal reactor operation that allows for better yields, fewer light ends and greater catalyst life. The technology reduces coking, because the process provides enough hydrogen in the solution when cracking reactions take place. As a result, the process yields longer catalyst life. Other advantages for refiners include lower total investment; reduced equipment delivery lead times; reduced maintenance and operating costs; and configuration flexibility. tabs., figs.

  16. Audit Keamanan SIMAK Berdasarkan ISO 27002 (Studi Kasus: FE UNUD

    Directory of Open Access Journals (Sweden)

    Yulius C. N. Bless

    2016-01-01

    Full Text Available Keamanan sistem informasi merupakan sebuah bagian vital yang menjadi perhatian khusus bagi setiap orang yang aktif menggunakan teknologi internet sebagai alat komunikasi dan informasi. Institusi pendidikan seperti universitas, yang menggunakan sistem informasi sebagai salah satu cara dalam manajemen informasi terkait administrasi pegawai dan mahasiswa, maupun informasi lainnya guna menunjang proses pengambilan keputusan. Sistem Informasi Manajemen Akademik (SIMAK di Fakultas Ekonomi Universitas Udayana berfungsi untuk manajemen data akademik mahasiswa. Informasi yang diolah dalam SIMAK haruslah memenuhi CIA (Confidentiality, Integrity, dan Availability. Audit dilakukan agar dapat diketahui tingkat kematangan sistem informasi saat ini. Standar dalam proses audit SIMAK menggunakan ISO/IEC 27002:2005 dan COBIT 4.1 untuk proses pemetaan dan penyusunan rekomendasi. Tingkat kematangan SIMAK saat ini adalah 3 atau Well Defined. Secara umum, tingkat kematangan ini dimaksudkan bahwa sudah terdapat prosedur yang standar dan telah didefinisikan secara baik, namun pelaksanaannya masih belum dilakukan secara rutin dan terstruktur.   Kata kunci: audit, COBIT 4.1, ISO/IEC 27002:2005, tingkat kematangan.

  17. IMPLEMENTASI MANAJEMEN MUTU ISO 9001: 2000 PADA SMKN 1 KALASAN

    Directory of Open Access Journals (Sweden)

    Jamiatun Jamiatun

    2015-10-01

    Full Text Available Penelitian ini bertujuan untuk mendeskripsikan  implementasi manajemen mutu  ISO 9001: 2000 pada mutu kinerja sekolah yang meliputi komponen input, proses, dan produk serta partisipasi orang tua siswa dalam pelaksanaan program-program sekolah di SMKN 1 Kalasan. Penelitian ini merupakan penelitian studi kasus dengan subjek penelitian  seluruh guru, karyawan, siswa dan orang tua siswa SMKN 1 Kalasan. Sampel dalam penelitian ini adalah guru dan karyawan SMKN 1 Kalasan yang telah mengabdi kurang lebih tiga tahun yang terdiri atas 84 guru dan 29 karyawan, dan orang tua/wali dan siswa yang duduk di kelas XII saat penelitian berlangsung terdiri atas 175 orang tua dan 312 siswa. Teknik analisis data yang digunakan dalam penelitian adalah deskriptif. Data dikumpulkan melalui  kuesioner, wawancara, observasi, dan dokumentasi. Hasil penelitian ini menunjukkan penilaian guru, karyawan, orang tua dan siswa terhadap mutu kinerja komponen input di SMKN 1 Kalasan sangat baik (63,19%, komponen proses sudah baik (50,35%, komponen produk sangat baik (73,61% dan partisipasi orang tua sangat baik (61,14%. Berdasarkan hasil ini, peneliti menyarankan bagi pihak SMKN 1 Kalasan untuk tetap melakukan perbaikan dalam implementasi Sistem Manajemen Mutu ISO 9001: 2000 agar mutu kinerja sekolah dapat ditingkatkan.

  18. ISO, unique explorer of the invisible cool universe

    Science.gov (United States)

    1995-10-01

    As Roger Bonnet, director of ESA's science programme, explains: "The ISO launch will be the culmination of twelve years of intensive effort to build tile mast powerful and precise infrared space telescope to dote, We fully expect astronomers in Europe. and all over the wand, to be rewarded with unprecedented insights into the particularly rich and fertile sources of the universe hidden in the infrared." For the mission looks set to mark a new step forward for astronomy. To date, infrared astronomy has always been hampered by two major difficulties. The first is that infrared radiation is thermal, calorific. This means that any body which is not absolutely cold naturally emits this type of "heat" or "hidden" radiation, Consequently, at the corresponding wavelengths, all telescopes, detectors and the Earth's atmosphere appear to shine spontaneously, Infrared observation is therefore tantamount to attempting to observe the stars in broad daylight using a telescope a million times more luminous than the stars themselves. Moreover, the atmosphere is partly or totally opaque to infrared light. Hence the great attraction of conducting such observations from space, above the Earth's atmospheric layers. using a very low-temperature telescope. The first - and, so far, truly - Satellite actually to have done so is the Infrared Astronomical Satellite (IRAS) - a joint UK/Dutch/US mission - which surveyed and catalogued the sky far ten months in 1983. A corner of the curtain was thus lifted, The scene was set. Now, the task is to observe each character, each object. And here, infrared astronomy is hampered by a second major difficulty: the very detection of light. For while infrared radiation was discovered back in 1800 (in the solar spectrum). infrared-sensitive photoelectric detectors did not materialise until the Second World War, IRAS itself had to make do without the multi-dimensional set-ups that would have allowed it to record true images. It had to build up its images

  19. Interim Report on ISO TC 163 Working Group 3. Annual progress report

    Energy Technology Data Exchange (ETDEWEB)

    Fairey, Philip [Florida Solar Energy Center, Cocoa, FL (United States)

    2009-04-02

    This reports cover the initial year efforts of the International Standards Organization (ISO) to develop international standards for rating the energy performance of buildings. The author of this report is a participant in this effort. This report summarizes the activities of the ISO Working Group charged with development of these standards and makes recommendations to the sponsors for future U.S. involvement in this ISO effort.

  20. A search for PAHs in the ISO spectra of comet Hale-Bopp

    Science.gov (United States)

    Crovisier, J.; Bockelée-Morvan, D.

    2007-12-01

    From a new analysis of a spectrum of comet C/1995 O1 (Hale-Bopp) obtained with the Infrared Space Observatory (ISO), Lisse et al. (2007) claimed the identification of many new dust species. Among them are PAHs, which were not found in our first analysis of the ISO spectra. We present a re-examination of the ISO observations of comet Hale-Bopp, which does not confirm the conclusion of Lisse et al.

  1. [Approval of ISO/IEC 17025 and quality control of laboratory testing].

    Science.gov (United States)

    Yamamoto, Shigeki; Asakura, Hiroshi; Machii, Kenji; Igimi, Shizunobu

    2010-01-01

    First section of Division of Biomedical Food Research, National Institute of Health Sciences (NIHS) was approved by ISO/IEC 17025 as a laboratory having an appropriate laboratory testing technique. NIHS is the first national laboratory approved by ISO/IEC 17025. NIHS has also been accepted the appropriate technique and facility for the BSL3 level pathogens by ISO/IEC 17025. NIHS is necessary to take an external audit almost every year. This approval is renewed every 4 years.

  2. Listen to ISO 9001:2015 for organizational competitiveness: Correlation between change management and improvement

    OpenAIRE

    Fonseca Luis Miguel; Domingues José Pedro

    2017-01-01

    In their quest to achieve superior performance and business results, organizations have extensively adopted models such as ISO 9001 Quality Managements Standards. Research supports that Quality Management System brings significant benefits for organizations competitiveness and success and more than 1 million organizations of all activity sectors worldwide have implemented ISO 9001. In a world of increasingly complexity and interconnection, the revised ISO 9001:2015 International Standard aims...

  3. Enantiomers of HA-966 (3-amino-1-hydroxypyrrolid-2-one) exhibit distinct central nervous system effects: (+)-HA-966 is a selective glycine/N-methyl-D-aspartate receptor antagonist, but (-)-HA-966 is a potent gamma-butyrolactone-like sedative

    International Nuclear Information System (INIS)

    Singh, L.; Donald, A.E.; Foster, A.C.; Hutson, P.H.; Iversen, L.L.; Iversen, S.D.; Kemp, J.A.; Leeson, P.D.; Marshall, G.R.; Oles, R.J.; Priestley, T.; Thorn, L.; Tricklebank, M.D.; Vass, C.A.; Williams, B.J.

    1990-01-01

    The antagonist effect of ±-3-amino-1-hydroxypyrrolid-2-one (HA-966) at the N-methyl-D-aspartate (NMDA) receptor occurs through a selective interaction with the glycine modulatory site within the receptor complex. When the enantiomers of ±-HA-966 were resolved, the (R)-(+)-enantiomer was found to be a selective glycine/NMDA receptor antagonist, a property that accounts for its anticonvulsant activity in vivo. In contrast, the (S)-(-)-enantiomer was only weakly active as an NMDA-receptor antagonist, but nevertheless it possessed a marked sedative and muscle relaxant action in vivo. In radioligand binding experiments, (+)-HA-966 inhibited strychnine-insensitive [ 3 H]glycine binding to rat cerebral cortex synaptic membranes with an IC 50 of 12.5 μM, whereas (-)-HA-966 had an IC 50 value of 339 μM. In mice, (+)-HA-966 antagonized sound and N-methyl-DL-aspartic acid (NMDLA)-induced seizures. The coadministration of D-serine dose-dependently antagonized the anticonvulsant effect of a submaximal dose of (+)-HA-966 against NMDLA-induced seizures. The sedative/ataxic effect of racemic HA-966 was mainly attributable to the (-)-enantiomer. It is suggested that, as in the case of the sedative γ-butyrolactone, disruption of striatal dopaminergic mechanisms may be responsible for this action

  4. ISO 13485: a complete guide to quality management in the medical device industry

    National Research Council Canada - National Science Library

    Abuhav, Itay

    2012-01-01

    .... Written by an experienced industry professional, this practical book provides a complete guide to the ISO 13485 standard certification for medical device manufacturing in terms of quality control...

  5. Global Impact Estimation of ISO 50001 Energy Management System for Industrial and Service Sectors

    Energy Technology Data Exchange (ETDEWEB)

    Aghajanzadeh, Arian [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Therkelsen, Peter L. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Rao, Prakash [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); McKane, Aimee T. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-08-01

    A methodology has been developed to determine the impacts of ISO 50001 Energy Management System (EnMS) at a region or country level. The impacts of ISO 50001 EnMS include energy, CO2 emissions, and cost savings. This internationally recognized and transparent methodology has been embodied in a user friendly Microsoft Excel® based tool called ISO 50001 Impact Estimator Tool (IET 50001). However, the tool inputs are critical in order to get accurate and defensible results. This report is intended to document the data sources used and assumptions made to calculate the global impact of ISO 50001 EnMS.

  6. Occupational exposures at nuclear power plants. Fourteenth annual report of the ISOE programme, 2004

    International Nuclear Information System (INIS)

    2006-01-01

    The ISOE Programme was created by the OECD Nuclear Energy Agency in 1992 to promote and co-ordinate international co-operative undertakings in the area of worker protection at nuclear power plants. The programme provides experts in occupational radiation protection with a forum for communication and exchange of experience. The ISOE databases enable the analysis of occupational exposure data from 478 operating and shutdown commercial nuclear power plants participating in the programme (representing some 90% of the world's total operating commercial reactors). The Fourteenth Annual Report of the ISOE Programme summarises achievements made during 2004 and compares annual occupational exposure data. Principal developments in ISOE participating countries are also described. (author)

  7. ISO-66, a novel inhibitor of macrophage migration, shows efficacy in melanoma and colon cancer models.

    Science.gov (United States)

    Ioannou, Kyriaki; Cheng, Kai Fan; Crichlow, Gregg V; Birmpilis, Anastasios I; Lolis, Elias J; Tsitsilonis, Ourania E; Al-Abed, Yousef

    2014-10-01

    Macrophage migration inhibitory factor (MIF) is a pleiotropic pro-inflammatory cytokine, which possesses a contributing role in cancer progression and metastasis and, thus, is now considered a promising anticancer drug target. Many MIF-inactivating strategies have proven successful in delaying cancer growth. Here, we report on the synthesis of ISO-66, a novel, highly stable, small-molecule MIF inhibitor, an analog of ISO-1 with improved characteristics. The MIF:ISO-66 co-crystal structure demonstrated that ISO-66 ligates the tautomerase active site of MIF, which has previously been shown to play an important role in its biological functions. In vitro, ISO-66 enhanced specific and non-specific anticancer immune responses, whereas prolonged administration of ISO-66 in mice with established syngeneic melanoma or colon cancer was non-toxic and resulted in a significant decrease in tumor burden. Subsequent ex vivo analysis of mouse splenocytes revealed that the observed decrease in tumor growth rates was likely mediated by the selective in vivo expansion of antitumor-reactive effector cells induced by ISO-66. Compared to other MIF-inactivating strategies employed in vivo, the anticancer activity of ISO-66 is demonstrated to be of equal or better efficacy. Our findings suggest that targeting MIF, via highly specific and stable compounds, such as ISO-66, may be effective for cancer treatment and stimulation of anticancer immune responses.

  8. Occupational exposures at nuclear power plants. Eleventh annual report of the Isoe programme, 2001

    International Nuclear Information System (INIS)

    2002-01-01

    The ISOE Programme was created by the OECD Nuclear Energy Agency in 1992 to promote and co-ordinate international co-operative undertakings in the area of worker protection at nuclear power plants. The programme provides experts in occupational radiation protection with a forum for communication and exchange of experience. The ISOE databases enable the analysis of occupational exposure data from the 452 commercial nuclear power plants participating in the programme (representing some 90 per cent of the world's total operating commercial reactors). The Eleventh Annual Report of the ISOE Programme summarises achievements made during 2001 and compares annual occupational exposure data. Principal developments in ISOE participating countries are also described. (author)

  9. The new ISO 6579-1: A real horizontal standard for detection of Salmonella, at last!

    Science.gov (United States)

    Mooijman, Kirsten A

    2018-05-01

    Up to 2016, three international standard methods existed for the detection of Salmonella spp. in food, animal feed and samples from the primary production stage: ISO 6785:2001 for milk and milk products, ISO 6579:2002 for (other) food and animal feed and Annex D of ISO 6579:2007 for samples from the primary production stage. In 2009, an ISO/CEN working group started with the revision of ISO 6579:2002 with two main aims: combining the three aforementioned standards in one document and improving the information in ISO 6579:2002. Additionally it was decided to split ISO 6579 into three parts, where part 1 describes the detection, part 2 the enumeration by mini-MPN (published in 2012) and part 3 the serotyping of Salmonella (published in 2014). This paper describes the experiments and choices made for improving the part on detection of Salmonella (ISO 6579-1). The final voting stage on (draft) ISO 6579-1 was finished by the end of December 2016, with a positive outcome. Finally, a real horizontal standard became available for detection of Salmonella in food, animal feed, environmental samples in the area of food production and food handling and in samples from the primary production stage in 2017. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Energy management systems in the practice. ISO 50001. A guideline for companies and institutions; Energiemanagementsysteme in der Praxis. ISO 50001. Leitfaden fuer Unternehmen und Organisationen

    Energy Technology Data Exchange (ETDEWEB)

    Kohlenborn, Walter; Kabisch, Sibylle; Klein, Johanna; Richter, Ina; Schuermann, Silas

    2012-06-15

    The guideline under consideration is an updated version of the guideline to the regulation EN 16001 and amended to ISO 50001. This contribution supports institutes in the implementation of an energy management system according to ISO 50001. The differences and commonalities to the European environment management system EMAS as well as to the regulation ISO 14001 are described. EMAS certified companies fulfil regularly all conditions of an energy management system. A practised energy management system is an excellent platform for the implementation of EMAS.

  11. Molecular aspects of zygotic embryogenesis in sunflower (Helianthus annuus L.): correlation of positive histone marks with HaWUS expression and putative link HaWUS/HaL1L.

    Science.gov (United States)

    Salvini, Mariangela; Fambrini, Marco; Giorgetti, Lucia; Pugliesi, Claudio

    2016-01-01

    The link HaWUS/ HaL1L , the opposite transcriptional behavior, and the decrease/increase in positive histone marks bond to both genes suggest an inhibitory effect of WUS on HaL1L in sunflower zygotic embryos. In Arabidopsis, a group of transcription factors implicated in the earliest events of embryogenesis is the WUSCHEL-RELATED HOMEOBOX (WOX) protein family including WUSCHEL (WUS) and other 14 WOX protein, some of which contain a conserved WUS-box domain in addition to the homeodomain. WUS transcripts appear very early in embryogenesis, at the 16-cell embryo stage, but gradually become restricted to the center of the developing shoot apical meristem (SAM) primordium and continues to be expressed in cells of the niche/organizing center of SAM and floral meristems to maintain stem cell population. Moreover, WUS has decisive roles in the embryonic program presumably promoting the vegetative-to-embryonic transition and/or maintaining the identity of the embryonic stem cells. However, data on the direct interaction between WUS and key genes for seed development (as LEC1 and L1L) are not collected. The novelty of this report consists in the characterization of Helianthus annuus WUS (HaWUS) gene and in its analysis regarding the pattern of the methylated lysine 4 (K4) of the Histone H3 and of the acetylated histone H3 during the zygotic embryo development. Also, a parallel investigation was performed for HaL1L gene since two copies of the WUS-binding site (WUSATA), previously identified on HaL1L nucleotide sequence, were able to be bound by the HaWUS recombinant protein suggesting a not described effect of HaWUS on HaL1L transcription.

  12. BiBTeX styl pro ČSN ISO 690 a ČSN ISO 690-2

    OpenAIRE

    Pyšný, Radek

    2009-01-01

    Tato práce popisuje průběh vytváření bibliografického stylu pro nástroj BibTeX, pomocí něhož lze v LaTeXu sázet bibliografické citace v souladu s normou ČSN ISO 690. V úvodu práce je proveden rozbor ČSN ISO 690. Následuje popis spolupráce mezi systémem LaTeX a nástrojem BibTeX. Podstatná část práce je věnována popisu struktury souborů, které BibTeX potřebuje pro svou funkci, tj. bibliografická databáze a bibliografický styl. Závěr této práce je věnovaný popisu vlastností vytvořeného bibliogra...

  13. IT内部統制に関する考察 : ISO27001 ISO9001の活用

    OpenAIRE

    赤林, 隆仁; Takahito, AKABAYASHI

    2007-01-01

    日本の上場企業はIT化が進展しており、内部統制においてもIT を前提としたものが要求される。そのための安価で適用し易いフレームワークとして多くの企業で経験のあるISO 27001(情報セキュリティシステム)、ISO 9001(品質システム)を活用できないかを検討した。その結果この2 つを併用するとIT を前提とする内部統制の要求事項を網羅できることが判明した。内部統制を意識して2 つの基準を適用すれば内部統制に係わる費用の削減につながることが推測された。...

  14. AHEAD. Advate in HaEmophilia A outcome Database.

    Science.gov (United States)

    Oldenburg, J; Kurnik, K; Huth-Kühne, A; Zimmermann, R; Abraham, I; Klamroth, R

    2010-11-01

    The clinical picture of haemophilia A patients is often characterised by recurrent bleedings, in particular joint bleeds. Thus far, long-term data on the outcome of haemophilia A patients are scarce as regards the development of target joints, joint replacement, lost days from school or work due to bleedings, and the quality of life, as most previous studies were limited to the aspects of safety and efficacy. The Baxter-initiated AHEAD (Advate in HaEmophilia A outcome Database) study is a multi-centre, prospective, non-interventional observational study of haemophilia A patients. All patients with a residual FVIII activity of £5% who are being treated with ADVATE are eligible. There are no limitations in terms of patient age or treatment regimen. AHEAD is scientifically supported by a renowned interdisciplinary steering board and is intended to yield data on 500 patients in up to 30 haemophilia centres, collected during a period of four years. The large patient population has been chosen in order to ensure a valid database. The objective of the study is to record haemophilia-related arthropathies, which will be defined based on imaging techniques (e. g. MRI, X-ray, ultrasound) and the judgment of the attending physician. In addition, extensive data will be collected on joint replacement surgeries, pseudotumour development, bleeding-related pain, quality of life (age-related questionnaires: Haem-A-QoL, Haemo-QoL, SF10, SF12v2), risk factors (diabetes mellitus, arterial hypertension, nicotine abuse), blood group, gene mutation, physical activity, and on the efficacy and safety of Advate. The patient data will be entered into an electronic CRF system at the centres. Plausibility checks during data entry, regular monitoring visits, and the option of auditing all serve to ensure a high data quality for AHEAD. The first patient was enrolled in the study in early June 2010; recruitment is planned to continue until the end of 2011. The Ethics Committee of the University

  15. ISO 50001 and SEP Faster and Cheaper - Exploring the Enterprise-Wide Approach

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Jingjing [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Rao, Prakash [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Therkelsen, Peter [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sheaffer, Paul [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Scheihing, Paul [USDOE, Washington, DC (United States); Tamm, Yannick [Energetics, Inc. (United States)

    2017-06-01

    ISO 50001 and other management systems (e.g., ISO 9001 and ISO 14001) allow for implementation and certification at the enterprise level. The "Central Office" concept, which allows a small group of employees to manage and facilitate the organization’s energy management system (EnMS) at the enterprise level, was introduced within the ISO 50003 standard to provide guidance to ISO 50001 certification bodies. Four industrial companies have partnered with the United States Department of Energy to pilot the enterprise-wide ISO 50001/SEP concept under the Better Buildings Superior Energy Performance (SEP) Enterprise-wide Accelerator. Each organization developed a Central Office to host their EnMS while implementing ISO 50001/SEP at multiple physically separated sites. The four corporate partners tailored their Central Office implementation model to meet their own specific circumstances and needs. This paper reviews the commonalities, differences, and benefits of each of these enterprise-wide implementation models, including organizational structures, Central Office staff responsibilities, and key strategies. The cost savings and benefits of using the enterprise-wide approach were assessed, including the cost per site compared with that of a conventional, single-site ISO 50001/SEP implementation approach. This paper also discusses the drivers for the cost reductions realized through these enterprise-wide approaches. The four partner companies worked with 30 total sites. On average, these 30 sites improved energy performance by 5% annually over their SEP achievement periods, saved more than $600,000 annually in energy costs and reduced implementation cost for ISO 50001 and SEP by $19,000 and 0.8 Full Time Equivalent × years (FTE-yr) of staff time per site. The results can inform other organizations seeking to implement enterprise-wide ISO 50001/SEP, as well as energy efficiency organizations seeking to promote wider adoption of ISO 50001 implementation.

  16. Inheritance rules for Hierarchical Metadata Based on ISO 19115

    Science.gov (United States)

    Zabala, A.; Masó, J.; Pons, X.

    2012-04-01

    Mainly, ISO19115 has been used to describe metadata for datasets and services. Furthermore, ISO19115 standard (as well as the new draft ISO19115-1) includes a conceptual model that allows to describe metadata at different levels of granularity structured in hierarchical levels, both in aggregated resources such as particularly series, datasets, and also in more disaggregated resources such as types of entities (feature type), types of attributes (attribute type), entities (feature instances) and attributes (attribute instances). In theory, to apply a complete metadata structure to all hierarchical levels of metadata, from the whole series to an individual feature attributes, is possible, but to store all metadata at all levels is completely impractical. An inheritance mechanism is needed to store each metadata and quality information at the optimum hierarchical level and to allow an ease and efficient documentation of metadata in both an Earth observation scenario such as a multi-satellite mission multiband imagery, as well as in a complex vector topographical map that includes several feature types separated in layers (e.g. administrative limits, contour lines, edification polygons, road lines, etc). Moreover, and due to the traditional split of maps in tiles due to map handling at detailed scales or due to the satellite characteristics, each of the previous thematic layers (e.g. 1:5000 roads for a country) or band (Landsat-5 TM cover of the Earth) are tiled on several parts (sheets or scenes respectively). According to hierarchy in ISO 19115, the definition of general metadata can be supplemented by spatially specific metadata that, when required, either inherits or overrides the general case (G.1.3). Annex H of this standard states that only metadata exceptions are defined at lower levels, so it is not necessary to generate the full registry of metadata for each level but to link particular values to the general value that they inherit. Conceptually the metadata

  17. The ISO standards and the cycle client provider

    Directory of Open Access Journals (Sweden)

    María Eugenia Palomeque-Solano

    2017-02-01

    Full Text Available Current managers are facing a relatively new situation: clients are every day more informed, and they have learned to demand better quality, more variety, faster response, and prices according to your expectations. Hence the importance of controlling the behavior of the relation input – product. The conditions in which products and services are marketed change, because of a set of phenomena that characterize the current market. Considerations on issues related to the understanding of the process approach of the family of ISO standards, in contrast to the impact they have on business performance, primarily in Latin America are summarized in this paper. The methodology used has been the document review, analysis, and synthesis via comparison with empirical experiences of the author.

  18. Enhancing quality using ISO 9001:2008 as a vehicle

    International Nuclear Information System (INIS)

    Hemantha Rao, G.V.S.; Rama Rao, B.S.

    2009-01-01

    Effectiveness of any function rests on three engines - technology, systems and people. Characterization and Quality Control of nuclear fuel is no an exception. Systems integrate people and technology. Technology without systems is creative chaos while systems without technology is mindless bureaucracy. People who man should bridge and blend these two proportionately. Systems provide both means and platform for continual improvement of quality. ISO 9001:2008, international standard for Quality Management System based on the eight principles of total quality management has been used as a driver for building and enhancing the quality of fuel fabricated at NFC. This paper brings out how this international standard has been used as a platform to continually upgrade the quality of fuel manufactured at NFC and its performance. Results thus far obtained are also discussed

  19. Business process mapping techniques for ISO 9001 and 14001 certifications

    Energy Technology Data Exchange (ETDEWEB)

    Klement, R.E.; Richardson, G.D.

    1997-11-01

    AlliedSignal Federal Manufacturing and Technologies/Kansas City (FM and T/KC) produces nonnuclear components for nuclear weapons. The company has operated the plant for the US Department of Energy (DOE) since 1949. Throughout the history of the plant, procedures have been written to reflect the nuclear weapons industry best practices, and the facility has built a reputation for producing high quality products. The purpose of this presentation is to demonstrate how Total Quality principles were used at FM and T/KC to document processes for ISO 9001 and 14001 certifications. The information presented to the reader will lead to a better understanding of business administration by aligning procedures to key business processes within a business model; converting functional-based procedures to process-based procedures for total integrated resource management; and assigning ownership, validation, and metrics to procedures/processes, adding value to a company`s profitability.

  20. ISO/TS 16949 system in quality aspect

    Directory of Open Access Journals (Sweden)

    Joanna Rosak-Szyrocka

    2014-12-01

    Full Text Available In the automotive industry the use of modern technology and provision of the highest quality product and related services is the most important element of rivalry between global corporations and motorcycles. In a competitive struggle for the recognition of its brand in the automotive market global organizations continuously raise the requirements for quality management systems, so that the finished product meets all the standards in terms of safety, quality and satisfying the ever-growing needs of customers - present and future drivers and passengers of cars. ISO/TS 16949 quality management system is presented in the paper. A framework for customer specific requirement as well as preventing problems is shown.

  1. IsoStar: A library of information about nonbonded interactions

    Science.gov (United States)

    Bruno, Ian J.; Cole, Jason C.; Lommerse, Jos P. M.; Rowland, R. Scott; Taylor, Robin; Verdonk, Marcel L.

    1997-11-01

    Crystallographic and theoretical (ab initio) data on intermolecular nonbondedinteractions have been gathered together in a computerised library('IsoStar`). The library contains information about the nonbonded contactsformed by some 250 chemical groupings. The data can be displayed visually andused to aid protein-ligand docking or the identification of bioisostericreplacements. Data from the library show that there is great variability inthe geometrical preferences of different types of hydrogen bonds, although ingeneral there is a tendency for H-bonds to form along lone-pair directions.The H-bond acceptor abilities of oxygen and sulphur atoms are highly dependenton intramolecular environments. The nonbonded contacts formed by manyhydrophobic groups show surprisingly strong directional preferences. Manyunusual nonbonded interactions are to be found in the library and are ofpotential value for designing novel biologically active molecules.

  2. A Martian PFS average spectrum: Comparison with ISO SWS

    Science.gov (United States)

    Formisano, V.; Encrenaz, T.; Fonti, S.; Giuranna, M.; Grassi, D.; Hirsh, H.; Khatuntsev, I.; Ignatiev, N.; Lellouch, E.; Maturilli, A.; Moroz, V.; Orleanski, P.; Piccioni, G.; Rataj, M.; Saggin, B.; Zasova, L.

    2005-08-01

    The evaluation of the planetary Fourier spectrometer performance at Mars is presented by comparing an average spectrum with the ISO spectrum published by Lellouch et al. [2000. Planet. Space Sci. 48, 1393.]. First, the average conditions of Mars atmosphere are compared, then the mixing ratios of the major gases are evaluated. Major and minor bands of CO 2 are compared, from the point of view of features characteristics and bands depth. The spectral resolution is also compared using several solar lines. The result indicates that PFS radiance is valid to better than 1% in the wavenumber range 1800-4200 cm -1 for the average spectrum considered (1680 measurements). The PFS monochromatic transfer function generates an overshooting on the left-hand side of strong narrow lines (solar or atmospheric). The spectral resolution of PFS is of the order of 1.3 cm -1 or better. A large number of narrow features to be identified are discovered.

  3. MOLES3: Implementing an ISO standards driven data catalogue

    Directory of Open Access Journals (Sweden)

    Graham A Parton

    2015-02-01

    Full Text Available ISO19156 Observations and Measurements (O&M provides a standardised framework for organising information about the collection of information about the environment.  Here we describe the implementation of a specialisation of O&M for environmental data, the Metadata Objects for Linking Environmental Sciences (MOLES3.MOLES3 provides support for organising information about data, and for user navigation around data holdings. The implementation described here, “CEDA-MOLES”, also supports data management functions for the Centre for Environmental Data Archival, CEDA. The previous iteration of MOLES (MOLES2 saw active use over five years, being replaced by CEDA-MOLES in late 2014. During that period important lessons were learnt both about the information needed, as well as how to design and maintain the necessary information systems. In this paper we review the problems encountered in MOLES2; how and why CEDA-MOLES was developed and engineered; the migration of information holdings from MOLES2 to CEDA-MOLES; and, finally, provide an early assessment of MOLES3 (as implemented in CEDA-MOLES and its limitations.Key drivers for the MOLES3 development included the necessity for improved data provenance, for further structured information to support ISO19115 discovery metadata  export (for EU INSPIRE compliance, and to provide appropriate fixed landing pages for Digital Object Identifiers (DOIs in the presence of evolving datasets. Key lessons learned included the importance of minimising information structure in free text fields, and the necessity to support as much agility in the information infrastructure as possible without compromising on maintainability both by those using the systems internally and externally (e.g. citing in to the information infrastructure, and those responsible for the systems themselves. The migration itself needed to ensure continuity of service and traceability of archived assets.

  4. ISO 14000: Origin, Structure, and Potential Barriers to Implementation.

    Science.gov (United States)

    Casto; Ellisen; Trnovec; Kross; Ginter

    1996-04-01

    The ISO 14000 is likely to become the international standard for environmental management. At present, it is an evolving series of individual voluntary standards and guideline reference documents that provide business management with the structure for managing environmental impacts. These encompass environmental management systems, environmental audits, eco-labeling, environmental performance evaluations, life-cycle assessment, and environmental aspects in product standards. The authors present the rationale for the ISO 14000 and the steps in its evolution so far, as well as its present provisions and their implications and its position with regard to regulatory agencies. Particular attention is paid to the consequences of voluntary disclosure and correction of violations. Hanley & Belfus, Inc. Int J Occup Environ Health 1077-3525 2 2 1996 April/June Perspectives on Rural Environmental Health in Central Europe 125 134 EN Tomas Trnovec Burton C. Kross CIREH-Room 352, International Center, University of Iowa, Iowa City, IA 52242, USA. Emil Ginter Life expectancy is about five to seven years less in Central European countries than in comparable countries in Western Europe. Environmental and occupational health risk factors, along with the socioeconomic and political conditions that have prevailed in this region for the past 40 years, are suspected contributing factors to this condition. The initial impression among observers was that environmental pollution by industry was the primary source of contamination leading to human health effects. Current thinking by the authors recognizes that combinations of personal habits, local environmental emissions (home heating), and occupational risk factors are more likely to be influencing the health of this region, particularly in rural areas. A predictive model for standard mortality rates determined that only three potential risk factors were statistically significant: consumption of alcoholic beverages, consumption of citrus

  5. Management system quality of service radio physics and RR. ISO 9001; Sistema de gestion de la calidad de un servicio de radiofisica y P. R. segun ISO 9001

    Energy Technology Data Exchange (ETDEWEB)

    Gil Agudo, A.; Torres Donaire, J.; Jimenez, J. C.; Carrascosa Fernandez, C.; Arjona Gutierrez, J.

    2011-07-01

    One of the tool increasingly deployed for the optimization of the procedures is the process management system according to a Quality Management. Likewise, for specific areas, such as central services within large institutions such as the General Hospitals of the systems of quality management is the most widely used ISO 9001. We describe in this paper our experience in implementing the system ISO 9001 in our Department of Radio physics and Radiation Protection (SRFPR).

  6. Migración de un SGSI basado en ISO/IEC 27001:2005 a la versión ISO/IEC 27001:2013

    OpenAIRE

    Espol; Rendón Freire, María José

    2015-01-01

    Este proyecto tiene como objetivo identificar los cambios en los requisitos de la norma ISO/IEC 27001:2013 respecto a la versión 2005, para lograr la actualización de un sistema de gestión de seguridad de la información basado en ISO/IEC 27001:2005 acorde a lo establecido en el nuevo estándar. Guayaquil Magíster en Seguridad Informática Aplicada

  7. A formal analysis of ISO/IEEE P11073-20601 standard of medical device communication

    NARCIS (Netherlands)

    Goga, Nicolae; Costache, Stefania; Moldoveanu, Florica

    2009-01-01

    This article presents the formal work done for the ISO/IEEE P11073-20601 Draft Standard for Health informatics - Personal health device communication - Application profile Optimized exchange protocol. ISO/IEEE 11073 family defines standards for device communication between agents (e.g. blood

  8. Exploratory Research of ISO 14001:2015 Transition among Portuguese Organizations

    Directory of Open Access Journals (Sweden)

    Luis Miguel Fonseca

    2018-03-01

    Full Text Available The purpose of this paper is the assessment of the ISO 14001:2015 transition process among Portuguese ISO 14001 certified organizations, including those that successfully have already achieved ISO 14001:2015 certification. A considerable number of the surveyed companies proceeded with the transition to the ISO 14001:2015 by introducing slight adjustments and were supported by external consultants. Nearly all of the respondent companies (97% intend to transition until 15th September 2018. The highest ranked reported benefit is the “integrated approach with other management sub-systems” with a well-consolidated perception from the surveyed companies. This is aligned with the ISO 14001:2015 goal of improving the compatibility of management standards supported on the Annex SL. “Alignment with business strategy”, “improved top management commitment” and “improved internal and external communication” are also perceived to obtain significant benefits from ISO 14001:2015. The statistical tests carried out (Kruskal–Wallis confirmed that the perception of some achieved ISO 14001:2015 certification benefits is dependent on the size of the organization. Concerning the motivations to proceed with certification, results suggest that there is not a particular company profile that is compelled to certify their EMS based on a specific type of motivation (Internal or External. Due to ISO 14001:2015 novelty, these exploratory results should be subjected to additional research confirmation.

  9. 78 FR 32384 - New England Power Generators Association v. ISO New England Inc.; Notice of Complaint

    Science.gov (United States)

    2013-05-30

    ... Power Generators Association v. ISO New England Inc.; Notice of Complaint Take notice that on May 17... New England Power Generators Association (Complainant) filed a formal complaint against ISO New...., Washington, DC 20426. This filing is accessible on-line at http://www.ferc.gov , using the ``eLibrary'' link...

  10. Formation of iso-ursodeoxycholic acid during administration of ursodeoxycholic acid in man

    NARCIS (Netherlands)

    Beuers, U.; Fischer, S.; Spengler, U.; Paumgartner, G.

    1991-01-01

    The appearance of iso-ursodeoxycholic acid (isoUDCA; 3 beta,7 beta-dihydroxy-5 beta-cholan-24-oic acid) in serum of patients with chronic cholestatic liver disease and of healthy subjects during administration of ursodeoxycholic acid (UDCA) is reported. Comparison of the mass spectrum of the newly

  11. The Influence of Academic Culture on Quality Management System ISO 9001 Maintenance within Malaysian Universities

    Science.gov (United States)

    Basir, Siti Arni; Davies, John; Douglas, Jacqueline; Douglas, Alexander

    2017-01-01

    This study investigates the influence of the elements of academic culture on quality management system ISO 9001 maintenance within Malaysian universities. There is a dearth of empirical studies on maintaining ISO 9001, particularly in the higher education context. From the literature review, academic culture was classified according to four…

  12. 77 FR 71585 - Brookfield Energy Marketing LP v. ISO New England Inc.; Notice of Complaint

    Science.gov (United States)

    2012-12-03

    ... Energy Marketing LP v. ISO New England Inc.; Notice of Complaint Take notice that on November 21, 2012...), Brookfield Energy Marketing LP (Complainant) filed a formal complaint against ISO New England Inc... notification when a document is added to a subscribed docket(s). For assistance with any FERC Online service...

  13. Perceptions About The ISO 9000 Quality System Standard Revision And Its Value: The Dutch Experience

    NARCIS (Netherlands)

    A. van der Wiele (Ton); J.D. van Iwaarden (Jos); A.R.T. Williams (Roger); B.G. Dale (Barry)

    2004-01-01

    textabstractThe aim of the research reported in this paper is to assess the relative value of the 2000 version of the ISO 9000 series of quality management system standards in comparison to the 1994 version. 773 organisations in the Netherlands which have all been certified to the ISO 9000 standard

  14. Vergelijking van een tijd besparende analysemethode voor hydroxyproline met ISO 3496-1978

    NARCIS (Netherlands)

    Cazemier, G.; Tuinstra, L.G.M.Th.; Werdmuller, G.A.

    1988-01-01

    De bepaling van hydroxyproline volgens de referentiemethode ISO 3496 is zeer tijdrovend. In een door het Nordisk Metodikkomitti för Livsmedel voorgestelde methode is een aantal wijzigingen ten opzichte van ISO 3496 aangebracht die de analysetijd per monster sterk verkorten. Om na te gaan of deze

  15. A primer on the Petri Net Markup Language and ISO/IEC 15909-2

    DEFF Research Database (Denmark)

    Hillah, L. M.; Kindler, Ekkart; Kordon, F.

    2009-01-01

    Standard, defines a transfer format for high-level nets. The transfer format defined in Part 2 of ISO/IEC 15909 is (or is based on) the \\emph{Petri Net Markup Language} (PNML), which was originally introduced as an interchange format for different kinds of Petri nets. In ISO/IEC 15909-2, however...

  16. Impacts of the ISO 14000 management system on sustainable forest management in South Africa

    CSIR Research Space (South Africa)

    Von Maltitz, Graham P

    2000-01-01

    Full Text Available are all issues that will lead to a unique ISO implementation within the country. ISO 14000 is not a product certification. As such it does not help companies market their products where ‘green labelling’ is becoming the norm. It is probably for this reason...

  17. 21 CFR 184.1165 - n-Butane and iso-butane.

    Science.gov (United States)

    2010-04-01

    ... FOR HUMAN CONSUMPTION (CONTINUED) DIRECT FOOD SUBSTANCES AFFIRMED AS GENERALLY RECOGNIZED AS SAFE Listing of Specific Substances Affirmed as GRAS § 184.1165 n-Butane and iso-butane. (a) n-Butane and iso..., odorless, flammable gases at normal temperatures and pressures. They are easily liquefied under pressure at...

  18. International standard (ISO) of radiation sterilization and issues in the sterilization dose setting

    International Nuclear Information System (INIS)

    Takehisa, Masaaki

    1995-01-01

    The ISO dose setting method 1 uses bioburden and verification by sublethal sterility test. Current devices produced in clean environmental have low bioburden, however, sensitivity of verification test declines at low bioburden. Validation of verification in this region should be further studied. A dose setting using D 10 of bioburden isolates should be reevaluated and included in the ISO. (author)

  19. Iso-α-acids, bitter components of beer, prevent obesity-induced cognitive decline.

    Science.gov (United States)

    Ayabe, Tatsuhiro; Ohya, Rena; Kondo, Keiji; Ano, Yasuhisa

    2018-03-19

    Dementia and cognitive decline have become worldwide public health problems, and it was recently reported that life-style related diseases and obesity are key risk factors in dementia. Iso-α-acids, hop-derived bitter components of beer, have been reported to have various physiological functions via activation of peroxisome proliferator-activated receptor γ. In this report, we demonstrated that daily intake of iso-α-acids suppresses inflammations in the hippocampus and improves cognitive decline induced by high fat diet (HFD). Body weight, epididymal fat weight, and plasma triglyceride levels were increased in HFD-fed mice, and significantly decreased in iso-α-acids supplemented HFD-fed mice. HFD feeding enhances the production of inflammatory cytokines and chemokines, such as TNF-α, which was significantly suppressed by iso-α-acids administration. HFD-induced neuroinflammation caused lipid peroxidation, neuronal loss, and atrophy in hippocampus, and those were not observed in iso-α-acids-treated mice. Furthermore, iso-α-acids intake significantly improved cognitive decline induced by HFD-feeding. Iso-α-acids are food derived components that suppressing both lipid accumulation and brain inflammation, thus iso-α-acids might be beneficial for the risk of dementia increased by obesity and lifestyle-related diseases.

  20. EPA STANDARDS NETWORK FACT SHEET: ISO 14000: INTERNATIONAL ENVIRONMENTAL MANAGEMENT STANDARDS

    Science.gov (United States)

    This flyer provides an overview of the ISO 14000 series of International standards, supplying a brief history, structure of the Technical Committee (TC) 207, structure of the U.S. Technical Advisory Group (TAG) to ISO TC-207, status of the Standards development as of June 1997, w...

  1. ISO 9001 certification for hospitals in Bulgaria: does it help service?

    Science.gov (United States)

    Stoimenova, Assena; Stoilova, Ani; Petrova, Guenka

    2014-03-04

    The aim of our study is to review the published literature on establishment and implementation of ISO 9001 QMS in European hospitals, to study the availability of International Organization for Standardization (ISO) quality management systems (QMS) in Bulgarian hospitals and to outline the main advantages of ISO implementation in the hospitals in Bulgaria. The information on availability of ISO QMS in the hospitals in Bulgaria was gathered via Bulgarian certification register, the registries of various quality associations, websites of hospitals and certification companies presented in Bulgaria. A total number of 312 hospitals in Bulgaria were screened for the availability of QMS certified against the ISO 9001 requirements. The experience of European hospitals that implemented QMS is positive and the used approaches to improve the processes and the demonstrated effects from ISO implementation are analysed by the researchers. Unlike other European Union member states, the establishment of quality management systems in Bulgaria is not compulsory. However, our study revealed that 14.42% of the hospitals in Bulgaria have implemented and have certified quality systems against the requirements of ISO 9001. Our study confirmed that a quality management system using the ISO 9001 standard is useful for the hospitals as it can help to increase the operational efficiencies, to reduce errors, improve patient safety and produce a more preventive approach instead of a reactive environment.

  2. Evaluation of ISO EN 13606 as a result of its implementation in XML.

    Science.gov (United States)

    Austin, Tony; Sun, Shanghua; Hassan, Taher; Kalra, Dipak

    2013-12-01

    The five parts of the ISO EN 13606 standard define a means by which health-care records can be exchanged between computer systems. Starting within the European standardisation process, it has now become internationally ratified in ISO. However, ISO standards do not require that a reference implementation be provided, and in order for ISO EN 13606 to deliver the expected benefits, it must be provided not as a document, but as an operational system that is not vendor specific. This article describes the evolution of an Extensible Markup Language (XML) Schema through three iterations, each of which emphasised one particular approach to delivering an executable equivalent to the printed standard. Developing these operational versions and incorporating feedback from users of these demonstrated where implementation compromises were needed and exposed defects in the standard. These are discussed herein. They may require a future technical revision to ISO EN 13606 to resolve the issues identified.

  3. Development of international standards for surface analysis by ISO technical committee 201 on surface chemical analysis

    International Nuclear Information System (INIS)

    Powell, C.J.

    1999-01-01

    Full text: The International Organization for Standardization (ISO) established Technical Committee 201 on Surface Chemical Analysis in 1991 to develop documentary standards for surface analysis. ISO/TC 201 met first in 1992 and has met annually since. This committee now has eight subcommittees (Terminology, General Procedures, Data Management and Treatment, Depth Profiling, AES, SIMS, XPS, and Glow Discharge Spectroscopy (GDS)) and one working group (Total X-Ray Fluorescence Spectroscopy). Each subcommittee has one or more working groups to develop standards on particular topics. Australia has observer-member status on ISO/TC 201 and on all ISO/TC 201 subcommittees except GDS where it has participator-member status. I will outline the organization of ISO/TC 201 and summarize the standards that have been or are being developed. Copyright (1999) Australian X-ray Analytical Association Inc

  4. Evaluation of ISO EN 13606 as a result of its implementation in XML

    Science.gov (United States)

    Sun, Shanghua; Hassan, Taher; Kalra, Dipak

    2013-01-01

    The five parts of the ISO EN 13606 standard define a means by which health-care records can be exchanged between computer systems. Starting within the European standardisation process, it has now become internationally ratified in ISO. However, ISO standards do not require that a reference implementation be provided, and in order for ISO EN 13606 to deliver the expected benefits, it must be provided not as a document, but as an operational system that is not vendor specific. This article describes the evolution of an Extensible Markup Language (XML) Schema through three iterations, each of which emphasised one particular approach to delivering an executable equivalent to the printed standard. Developing these operational versions and incorporating feedback from users of these demonstrated where implementation compromises were needed and exposed defects in the standard. These are discussed herein. They may require a future technical revision to ISO EN 13606 to resolve the issues identified. PMID:23995217

  5. Implementation of ISO 10110 optics drawing standards for the National Ignition Facility

    International Nuclear Information System (INIS)

    Aikens, D. M.; English, R. E.; Wang, D. Y.

    1999-01-01

    The National Ignition Facility (NIF) project elected to implement ISO 10110 standard for the specifications of NIF optics drawings in 1996. More than 7,000 NIF large optics and 20,000 NIF small optics will be manufactured based on ISO 10110 indications. ISO 10110 standard meets many of the needs of the NIF optics specifications. It allows the optical engineer to quantify and clearly communicate the desired optical specifications. While no single drawing standard specifies all the requirements of high energy laser system, a combination of ISO 10110 standard with detailed notes make it possible to apply international drawing standards to the NIF laser system. This paper will briefly describe LLNL's interpretation and implementation of the ISO 10110 drawing standard, present some examples of NIF optics drawings, and discuss pros and cons of the indications from the perspective of this application. Emphasis will be given to the surface imperfection specifications, known as 5/, for the NIF optics

  6. PENGARUH CSR BERDASAR ISO 26000 TERHADAP NILAI PERUSAHAAN DENGAN KARAKTERSITIK PERUSAHAAN SEBAGAI VARIABEL MODERATING

    Directory of Open Access Journals (Sweden)

    Sri Wahjuni Latifah

    2015-01-01

    Full Text Available Research of the influence of ISO 26000 CSR toward the company’s value as a moderating variable which is done on companies listed in Indonesia Stock Exchange. The Company’s characteristics are measured by firm age, size, leverage and profitability. The data analysis was done by using double linear regression models, the first is to see the effect based on the ISO 26000 CSR and firm characteristics on value, and the second is to see the effect of interaction with the ISO 26000 corporate characteristics. The results of the study showed that there was no influence of ISO 26000, the characteristics of the company toward the value of the company. However, moderated ISO 26000 by firm characteristics affect the value of the company.

  7. Approaches to the ISO/IEC 17025 accreditation for Pu and U accountancy analysis

    International Nuclear Information System (INIS)

    Okazaki, Hiro; Sumi, Mika; Abe, Katsuo; Sato, Mitsuhiro; Kageyama, Tomio

    2013-01-01

    The quality control section of Plutonium Fuel Development Center (PFDC) of Japan Atomic Energy Agency has been analyzing isotopic compositions by Mass Spectrometry as well as content by Isotope Dilution Mass Spectrometry (IDMS) of plutonium and uranium in nuclear materials. Along with establishing and managing the quality assurance system, ensuring the reliability of the analysis data is important. PFDC has been establishing the quality management system with ISO9001. ISO9001 consists of management requirements for quality system of organizations. While ISO/IEC 17025 consists of technical requirements for the competence of testing and calibration laboratories in addition to the management requirements. The quality control section addressed technical improvement to improve further reliability of analysis quality and we have accredited for ISO/IEC 17025 of isotopic compositions and content of plutonium and uranium in nuclear materials in March 2010. In this presentation, we report our approaches to the ISO/IEC 17025 accreditation and operation status. (author)

  8. Implementation of ISO 10110 optics drawing standards for the National Ignition Facility

    Science.gov (United States)

    Wang, David Y.; English, R. Edward, Jr.; Aikens, David M.

    1999-11-01

    The National Ignition Facility (NIF) project elected to implement ISO 10110 standard for the specifications of NIF optics drawings in 1996. More than 7,000 NIF large optics and 20,000 NIF small optics will be manufactured based on ISO 10110 indications. ISO 10110 standard meets many of the needs of the NIF optics specifications. It allows the optical engineer to quantify and clearly communicate the desired optical specifications. While no single drawing standard specifies all the requirements of high energy laser system, a combination of ISO 10110 standard with detailed notes make it possible to apply international drawing standards to the NIF laser system. This paper will briefly describe LLNL's interpretation and implementation of the ISO 10110 drawing standard, present some examples of NIF optics drawings, and discuss pros and cons of the indications from the perspective of this application. Emphasis will be given to the surface imperfection specifications, known as 5/, for the NIF optics.

  9. Application of ISO 9001:2000 in a Nuclear Medicine Department

    International Nuclear Information System (INIS)

    Rayo, J.I.; Serrano, J.; Martin, R.; Corral, C.

    2002-01-01

    Since 1947 ISO has been developing voluntary technical standards over almost all sectors of business, industry, and technology. The ISO 9000 standards were published in 1987, and new versions of the standards saw daylight in 1994 and 2000. The highlights of ISO 9001:2000 are: quality management system, management responsibility, resource management, product realization and measurement, analysis and improvement. Aim: Application of ISO 9001:2000 to a Nuclear Medicine Department for provides the organization with a model to follow, customer focus, people will understand the goals of the organization and are motivated to work for objectives and lower costs and shorter cycle times through effective use of resources. Conclusion: ISO 9001:2000 focuses on continual improvement of business processes that should be a permanent objective of the Nuclear Medicine Department

  10. Occupational exposures at nuclear power plants. Twelfth annual report of the Isoe programme, 2002

    International Nuclear Information System (INIS)

    2004-01-01

    The Information System on Occupational Exposure (ISOE) was created by the OECD Nuclear Energy Agency in 1992 to promote and co-ordinate international co-operative undertakings in the area of worker protection at nuclear power plants. The ISOE Programme provides experts in occupational radiation protection with a forum for communication and exchange of experience. The ISOE databases enable the analysis of occupational exposure data from the 465 commercial nuclear power plants participating in the Programme (representing some 90 per cent of the world's total operating commercial reactors). The Twelfth Annual Report of the ISOE Programme summarises achievements made during 2002 and compares annual occupational exposure data. Principal developments in ISOE participating countries are also described. (author)

  11. Organizational leadership: A study on the affects of certification to International Organization for Standardization (ISO)

    Science.gov (United States)

    Cowart, Jewel S.

    Compliance to requirements of ISO is an important leadership problem for the International Aerospace Quality Group (IAQG) and the Aviation, Space and Defense (AS&D) companies. Furthermore, the IAQG seeks to understand the valuation of ISO/AS9100 requirements (2009), audit practices, management functions, business performance, customer satisfaction, and potential future concepts for the standard to assure quality. Since the release of the AS9100C total certification growth surpassed 1,100,000 organizations in 2010 with ISO 9001 series adoption and implementation governing business operations (ASQ, 2012b; ISO, 2011; Bernardo, Llach, & Marimon, 2011). Historians such as Crosby, Juran, Deming, and others established the foundation for quality assurance. Several researchers explored the issues which complicate overall benefits of ISO certification (Iwaro & Mwasha, 2012; Karthi et al., 2012; Sampaio et al., 2009). This study examined the effects on AS&D industries from ISO compliance to identify the implications (of ever-changing requirements) through an online survey of 15,000 practitioners. The research illuminated how ISO affects AS&D industries with current and future requirements for certification. The data showed that 75% of survey respondents report implementation of the AS9100C requirements still has benefits that outweigh the cost. Findings suggest that AS&D industries perceive significant value in the AS9100C document as part of the overall ISO 9000 series. In general, the comments from the survey can provide insight into the affects of ISO certification. The study concludes by recommending continued research to learn of further impacts from ISO certification within AS&D industries to improve the AS9100 document requirements for quality management systems.

  12. Neuroprotective effects of α-iso-cubebenol on glutamate-induced neurotoxicity.

    Science.gov (United States)

    Park, Sun Young; Choi, Yung Hyun; Park, Geuntae; Choi, Young-Whan

    2015-09-01

    α-Iso-cubebenol is a natural compound isolated from Schisandra chinensis, and is reported to have beneficial bioactivity including anti-inflammatory and anti-tumor activities. Glutamate-induced oxidative neuronal damage has been implicated in a variety of neurodegenerative disorders. Here we investigated the mechanisms of α-iso-cubebenol protection of mouse hippocampus-derived neuronal cells (HT22 cells) from apoptotic cell death induced by the major excitatory neurotransmitter, glutamate. Pretreatment with α-iso-cubebenol markedly attenuated glutamate-induced loss of cell viability and release of lactate dehydrogenase), in a dose-dependent manner. α-Iso-cubebenol significantly reduced glutamate-induced intracellular reactive oxygen species and calcium accumulation. Strikingly, α-iso-cubebenol inhibited glutamate-induced mitochondrial depolarization, which releases apoptosis-inducing factor from mitochondria. α-Iso-cubebenol also suppressed glutamate-induced phosphorylation of extracellular-signal-regulated kinases. Furthermore, α-iso-cubebenol induced CREB phosphorylation and Nrf-2 nuclear accumulation and increased the promoter activity of ARE and CREB in HT22 cells. α-Iso-cubebenol also upregulated the expression of phase-II detoxifying/antioxidant enzymes such as HO-1 and NQO1. Subsequent studies revealed that the inhibitory effects of α-iso-cubebenol on glutamate-induced apoptosis were abolished by small interfering RNA-mediated knockdown of CREB and Nrf-2. These findings suggest that α-iso-cubebenol prevents excitotoxin-induced oxidative damage to neurons by inhibiting apoptotic cell death, and might be a potential preventive or therapeutic agent for neurodegenerative disorders. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Blood and urine 8-iso-PGF2α levels in babies of different gestational ages.

    Science.gov (United States)

    Li, Sitao; Hao, Hu; Zhou, Ping; Gao, Ping Ming; Xiao, Xin

    2014-01-01

    We measured cord blood and urine 8-iso-prostaglandin F2α (8-iso-PGF2α) levels in babies of different gestational ages to determine lipid peroxidation status. Babies at gestational ages of 28-43 weeks were divided into group A (28-32 weeks), group B (33-36 weeks), group C (37-41 weeks), and group D (42-43 weeks). 8-iso-PGF2α in umbilical cord blood (UCB) at birth and urine at 6 hours after birth was and tested by ELISA. UCB and urine 8-iso-PGF2α levels in group C were 130.09 ± 31.73 pg/ml and 27.14 ± 6.73 pg/ml, respectively. UCB 8-iso-PGF2α levels in group A and B were 188.42 ± 59.34 pg/ml and 189.37 ± 68.46 pg/ml, and urine 8-iso-PGF2α were 32.14 ± 7.32 pg/ml and 30.46 ± 8.83 pg/ml, respectively. Blood and urine 8-iso-PGF2α levels in group D (post-term) were 252.01 ± 46.42 pg/ml and 44.00 ± 8.50 pg/ml. For all babies, UCB and urine iso-PGF2α levels were significantly correlated (r = 0.65, P iso-PGF2α levels in normal full-term babies. Urine 8-iso-PGF2α levels may reflect the extent of lipid peroxidation in babies. In pre-term and post-term babies, there was evidence for increased lipid peroxidation.

  14. Adopting ISO 9712:2005 and ISO/IEC 17024:2003 as Philippine national standard for NDT for global competitiveness

    International Nuclear Information System (INIS)

    Banaga, Renato T.; Mateo, Alejandro J.

    2005-01-01

    This paper describes and promotes the adoption of ISO 9712: 2005 edition and the ISO/IEC 17024: 2003 edition by the Philippines to be globally competitive. ISO 9712 is a standard for qualifications and certification of nondestructive testing (NDT) personnel while ISO/IEC 17024 is conformity assessment-general requirements for bodies operating certification of persons. ISO 9712 defies that the effectiveness of an application of nondestructive testing depends on the capabilities and qualifications of personnel performing the NDT test. The Philippines through the national certifying body (NCB) implements the certification of proficiency of NDT personnel in accordance with the Philippine National Standards (PNS-146: 1998) This standard (formerly PNS-146: 1987) was originally based from the draft ISO/TC-135/SC7N35.3 and was later revised to conform to the latest ISO FDIS 9712: 1997 and rename PNS-146: 1998. Now with the issuance of the latest ISO 9712:2005 edition and to keep abreast with the current trends of NDT technology, present time and conditions dictates for us to revise our NDT personnel certification to the latest edition of ISO 9712. The International Atomic Energy Agency (IAEA) supports the establishment of a common NDT standard. The IAEA is promoting af financially supporting the establishment in developing countries of only one NDT standard. The IAEA through the Regional Cooperative Agreement (RCA) has initiated the harmonization of the NDT qualification and certification of personnel in the RCA member states. In October 2001, the IAEA sponsored the Dhaka meeting where the International Committee for Nondestructive Testing (ICNDT), Asia-Pacific Committee (APCNDT) and RCA member states representatives drafted a Mutual Recognition Agreement (MRA) for the Asia-Pacific NDT (APCNDT) personnel certification schemes acording to ISO 9712. Last August 2005, IAEA/RCA sponsored the Colombo meeting for the harmonization of regional NDT applying ISO 9712 and ISO

  15. Hyaluronan (HA) interacting proteins RHAMM and hyaluronidase impact prostate cancer cell behavior and invadopodia formation in 3D HA-based hydrogels.

    Science.gov (United States)

    Gurski, Lisa A; Xu, Xian; Labrada, Lyana N; Nguyen, Ngoc T; Xiao, Longxi; van Golen, Kenneth L; Jia, Xinqiao; Farach-Carson, Mary C

    2012-01-01

    To study the individual functions of hyaluronan interacting proteins in prostate cancer (PCa) motility through connective tissues, we developed a novel three-dimensional (3D) hyaluronic acid (HA) hydrogel assay that provides a flexible, quantifiable, and physiologically relevant alternative to current methods. Invasion in this system reflects the prevalence of HA in connective tissues and its role in the promotion of cancer cell motility and tissue invasion, making the system ideal to study invasion through bone marrow or other HA-rich connective tissues. The bio-compatible cross-linking process we used allows for direct encapsulation of cancer cells within the gel where they adopt a distinct, cluster-like morphology. Metastatic PCa cells in these hydrogels develop fingerlike structures, "invadopodia", consistent with their invasive properties. The number of invadopodia, as well as cluster size, shape, and convergence, can provide a quantifiable measure of invasive potential. Among candidate hyaluronan interacting proteins that could be responsible for the behavior we observed, we found that culture in the HA hydrogel triggers invasive PCa cells to differentially express and localize receptor for hyaluronan mediated motility (RHAMM)/CD168 which, in the absence of CD44, appears to contribute to PCa motility and invasion by interacting with the HA hydrogel components. PCa cell invasion through the HA hydrogel also was found to depend on the activity of hyaluronidases. Studies shown here reveal that while hyaluronidase activity is necessary for invadopodia and inter-connecting cluster formation, activity alone is not sufficient for acquisition of invasiveness to occur. We therefore suggest that development of invasive behavior in 3D HA-based systems requires development of additional cellular features, such as activation of motility associated pathways that regulate formation of invadopodia. Thus, we report development of a 3D system amenable to dissection of

  16. SINERGI ISO 9001:2000 - CMMI PADA INDUSTRI PENGEMBANG PERANGKAT LUNAK

    Directory of Open Access Journals (Sweden)

    Leo Willyanto Santoso

    2005-01-01

    Full Text Available All sectors of society including softwere industry, have a big concern about quality, both of product quality and service quality. The need to manage risk, has a strong relation with quality and increases system complexity. Standarization in determining quality, ISO is a must for all software developer. If we study further, ISO 9001:2000 still has some weakness especially for implementation in software product. This paper presents a comparative analysis of quality approaches to risk management. This paper also provide a general overview of all the risks aspects treated in ISO 9001:2000 standards and CMMI model version 1.1. In this research, we obtain a strategy to implement ISO 9001:2000 and CMMI together when we make a planing to increase software process. Besides it produces analysis how to change position from ISO 9001:2000 to CMMI. In the implementation on software industry PT 'X', obtain get various benefits that has never been obtained before. Abstract in Bahasa Indonesia : Semua hal dalam hidup ini selalu memperhatikan masalah kualitas, baik itu berupa kualitas produk ataupun kualitas layanan. Pada industri perangkat lunak, hal ini tidak dibedakan, kebutuhan untuk menghasilkan produk yang berkualitas akan meningkatkan kekompleksan dari sebuah sistem. Standarisasi dalam penentuan kualitas, ISO sudah menjadi keharusan bagi para pengembang perangkat lunak. Apabila diteliti lebih lanjut, ISO 9001:2000 masih mempunyai banyak kekurangan, khususnya untuk diaplikasikan dalam produk perangkat lunak.Pada penelitian ini, akan dibahas analisis perbandingan dengan melakukan pendekatan kualitas untuk meningkatkan proses perangkat lunak dengan melakukan mapping antara ISO 9001:2000 dengan CMMI. Hal-hal yang dibahas berupa aspek-aspek dari standard ISO dan CMMI versi 1.1. Pada penelitian ini, dapat diperoleh strategi untuk menerapkan ISO 9001:2000 dan CMMI secara sinergi ketika merencanakan untuk melakukan peningkatan proses perangkat lunak. Selain itu

  17. The Technology and Properties of Digital Double Pulse Electrodepositing Ni-HA Composite Coating of Bioceramics

    Institute of Scientific and Technical Information of China (English)

    DONG He-yan; WANG Zhou; SHI Gu-guizhi; FU Chuan-qi; CHEN Wei-rong; JIN Zhong-hong; LI Yan

    2004-01-01

    This article discusses and analyses the technology, the surface image, microstructure and ability of digital double pulse electrodepositing Ni-HA composite coatings of bioceramics made on 1Crl8Ni9Ti substrate by SEM ,XRD and so on. The results shows that ( 1 ) the HA particles exit in substrate uniformly; (2) XRD result shows that there are HA peaks at 78. 023 ° ,43. 246°and 73. 120°differently; (3) The microhardnees of the composite coatings is increased with the rise of content of HA particles, and on the same conditions the microhardnees value is greater than that of common non-pulse electrodepositing Ni-HA composite coatings of bioceramics. (4) The grain size of digital double pulse electrodepositing Ni-HA composite coatings of bioceramics is much thinner than that of common D. C.

  18. Preparation and characterization of bio-composite PEEK/nHA

    Science.gov (United States)

    Jin, Y. S.; Bian, C. C.; Zhang, Z. Q.; Zhao, Y.; Yang, L.

    2017-01-01

    PEEK/nHA composite material, with excellent mechanical property as polyetheretherketone (PEEK) and biological activity as hydroxyapatite (HA), has attracted wide attention of medical experts and materials science experts. The addition of hydroxyapatite was the decisive factor for biological activity in PEEK/nHA composite. In this paper, acicular nanohydroxyapatite was prepared by chemical precipitation method with Ca(NO3)2, (NH4)2HPO4 as raw material; PEEK/nHA composite was prepared by solution blending and vacuum sintering method. The composite was characterized with FT-IR, XRD, DSC, TG and mechanical property test. Results showed that the composite has good thermal stability and compressive property when the mass ratio of PEEK to nHA is 10:3; and high nHA content can improve the biological activity of the composite, which can meet the basic requirements for bone tissue engineering scaffold.

  19. Sustainable development induction in organizations: a convergence analysis of ISO standards management tools' parameters.

    Science.gov (United States)

    Merlin, Fabrício Kurman; Pereira, Vera Lúciaduarte do Valle; Pacheco, Waldemar

    2012-01-01

    Organizations are part of an environment in which they are pressured to meet society's demands and acting in a sustainable way. In an attempt to meet such demands, organizations make use of various management tools, among which, ISO standards are used. Although there are evidences of contributions provided by these standards, it is questionable whether its parameters converge for a possible induction for sustainable development in organizations. This work presents a theoretical study, designed on structuralism world view, descriptive and deductive method, which aims to analyze the convergence of management tools' parameters in ISO standards. In order to support the analysis, a generic framework for possible convergence was developed, based on systems approach, linking five ISO standards (ISO 9001, ISO 14001, OHSAS 18001, ISO 31000 and ISO 26000) with sustainable development and positioning them according to organization levels (strategic, tactical and operational). The structure was designed based on Brundtland report concept. The analysis was performed exploring the generic framework for possible convergence based on Nadler and Tushman model. The results found the standards can contribute to a possible sustainable development induction in organizations, as long as they meet certain minimum conditions related to its strategic alignment.

  20. Shikonin ameliorates isoproterenol (ISO)-induced myocardial damage through suppressing fibrosis, inflammation, apoptosis and ER stress.

    Science.gov (United States)

    Yang, Jun; Wang, Zhao; Chen, Dong-Lin

    2017-09-01

    Shikonin, isolated from the roots of herbal plant Lithospermum erythrorhizon, is a naphthoquinone. It has been reported to exert beneficial anti-inflammatory effects and anti-oxidant properties in various diseases. Isoproterenol (ISO) has been widely used to establish cardiac injury in vivo and in vitro. However, shikonin function in ISO-induced cardiac injury remains uncertain. In our study, we attempted to investigate the efficiency and possible molecular mechanism of shikonin in cardiac injury treatment induced by ISO. In vivo, C57BL6 mice were subcutaneously injected with 5mg/kg ISO to induce heart failure. And mice were given a gavage of shikonin (2 or 4mg/kg/d, for four weeks). Cardiac function, fibrosis indices, inflammation response, apoptosis and endoplasmic reticulum (ER) stress were calculated. Pathological alterations, fibrosis-, inflammation-, apoptosis- and ER stress-related molecules were examined. In ISO-induced cardiac injury, shikonin significantly ameliorated heart function, decreased myocardial fibrosis, suppressed inflammation, attenuated apoptosis and ER stress through impeding collagen accumulation, Toll like receptor 4/nuclear transcription factor κB (TLR4/NF-κB), Caspase-3 and glucose-regulated protein 78 (GRP78) signaling pathways activity, relieving heart failure in vivo. Also, in vitro, shikonin attenuated ISO-induced cardiac muscle cells by reducing fibrosis, inflammation, apoptosis and ER stress. Our findings indicated that shikonin treatment attenuated ISO-induced heart injury, providing an effective therapeutic strategy for heart failure treatment for future. Copyright © 2017. Published by Elsevier Masson SAS.

  1. Plasma 8-iso-Prostaglandin F2α concentrations and outcomes after acute intracerebral hemorrhage.

    Science.gov (United States)

    Du, Quan; Yu, Wen-Hua; Dong, Xiao-Qiao; Yang, Ding-Bo; Shen, Yong-Feng; Wang, Hao; Jiang, Li; Du, Yuan-Feng; Zhang, Zu-Yong; Zhu, Qiang; Che, Zhi-Hao; Liu, Qun-Jie

    2014-11-01

    Higher plasma 8-iso-Prostaglandin F2α concentrations have been associated with poor outcome of severe traumatic brain injury. We further investigated the relationships between plasma 8-iso-Prostaglandin F2α concentrations and clinical outcomes in patients with acute intracerebral hemorrhage. Plasma 8-iso-Prostaglandin F2α concentrations of 128 consecutive patients and 128 sex- and gender-matched healthy subjects were measured by enzyme-linked immunosorbent assay. We assessed their relationships with disease severity and clinical outcomes including 1-week mortality, 6-month mortality and unfavorable outcome (modified Rankin Scale score>2). Plasma 8-iso-Prostaglandin F2α concentrations were substantially higher in patients than in healthy controls. Plasma 8-iso-Prostaglandin F2α concentrations were positively associated with National Institutes of Health Stroke Scale (NIHSS) scores and hematoma volume using a multivariate linear regression. It emerged as an independent predictor for clinical outcomes of patients using a forward stepwise logistic regression. ROC curves identified the predictive values of plasma 8-iso-Prostaglandin F2α concentrations, and found its predictive value was similar to NIHSS scores and hematoma volumes. However, it just numerically added the predictive values of NIHSS score and hematoma volume. Increased plasma 8-iso-Prostaglandin F2α concentrations are associated with disease severity and clinical outcome after acute intracerebral hemorrhage. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Mapping ‘hydroscapes’ along the iso- to anisohydric continuum of stomatal regulation of plant water status

    Science.gov (United States)

    Frederick C. Meinzer; David R. Woodruff; Danielle E. Marias; Duncan D. Smith; Katherine A. McCulloh; Ava R. Howard; Alicia L. Magedman; Josep Penuelas

    2016-01-01

    The concept of iso- vs. anisohydry has been used to describe the stringency of stomatal regulation of plant water potential (ψ). However, metrics that accurately and consistently quantify species’ operating ranges along a continuum of iso- to anisohydry have been elusive. Additionally, most approaches to quantifying iso/anisohydry require labour-intensive measurements...

  3. 75 FR 3225 - Notice of Commission Staff Attendance at Organization of MISO States and Midwest ISO Meetings

    Science.gov (United States)

    2010-01-20

    ... Organization of MISO States and Midwest ISO Meetings January 12, 2010. The Federal Energy Regulatory Commission...: Midwest ISO Headquarters, 720 City Center Drive, Carmel, IN 46032. Except as otherwise noted above, the... Operator, Inc. Docket No. ER08-15, Midwest ISO Transmission Owners Docket No. ER08-55, Midwest Independent...

  4. 76 FR 7839 - Notice of Commission and Commission Staff Attendance at ISO/RTO Council and Regional State...

    Science.gov (United States)

    2011-02-11

    ... Staff Attendance at ISO/RTO Council and Regional State Committees Meeting The Federal Energy Regulatory... ISO/RTO Council and Regional State Committees meeting: Saturday, February 12, 2011, 1 p.m.-4 p.m... following proceeding: Docket No. AD10-5-000, RTO/ISO Performance Metrics. For more information, contact...

  5. Degradation behavior and compatibility of micro, nanoHA/chitosan scaffolds with interconnected spherical macropores.

    Science.gov (United States)

    Ruixin, Li; Cheng, Xu; Yingjie, Liu; Hao, Li; Caihong, Shi; Weihua, Su; Weining, An; Yinghai, Yuan; Xiaoli, Qin; Yunqiang, Xu; Xizheng, Zhang; Hui, Li

    2017-10-01

    Hydroxyapatite/Chitosan (HA/CS) composite have significant application in biomedical especially for bone replacement. Inorganic particle shape and size of composite affect the scaffold mechanical property, biological property, and degradation. The aim of this study was to fabricate HA/CS scaffold with good pore connectivity and analyze their biological, degradation properties. Microhydroxyapatite/chitosan (mHA/CS) and nanohydroxyapatite/chitosan (nHA/CS) composite scaffolds with interconnected spherical pore architectures were fabricated. Composite scaffolds structure parameters were analyzed using micro CT. Cell proliferation and morphology were tested and compared between two scaffolds using mouse osteoblastic cell line MC3T3-E1. To research the composite degradation in lysozyme PBS solution, degradation rate and reducing sugar content were tested, and scaffolds morphology were observed by SEM. The results showed that microHA and nanoHA were fabricated by being calcined and synthesis methods, and their infrared spectra are very similar. EDAX composition analysis demonstrated that both of microHA and nanoHA were calcium deficiency HA. Micro-CT results demonstrated the scaffolds had interconnected spherical pores, and the structure parameters were similar. Cell viabilities were significant increased with cultured time, but there were no significant difference between microHA/CS and nanoHA/CS scaffolds. Scaffold structure was gradually destroyed and inorganic composition HA particles are more prominent with degradation time. (1) Inorganic particle shape and size of composite affect the scaffold mechanical property, biological property, and degradation. NanoHA/CS and microHA/CS scaffolds with good pore connectivity were fabricated and their biological, degradation properties were studied in this manuscript. (2) The scaffold with interconnected porosity construct provides the necessary support for cells to proliferate and maintain their differentiated function, and

  6. A study on improving mechanical properties of porous HA tissue engineering scaffolds by hot isostatic pressing

    International Nuclear Information System (INIS)

    Zhao Jing; Xiao Suguang; Lu Xiong; Wang Jianxin; Weng Jie

    2006-01-01

    Various interconnected porous hydroxyapatite (HA) ceramic scaffolds are universally used to induct the tissue growth for bone repair and replacement, and serve to support the adhesion, transfer, proliferation and differentiation of cells. Impregnation of polyurethane sponges with a ceramic slurry is adopted to produce highly porous HA ceramic scaffolds with a 3D interconnected structure. However, high porosity always accompanies a decrease in the strength of the HA ceramic scaffolds. Therefore, it is significant to improve the strength of the HA ceramic scaffolds with highly interconnected porosity so that they are more suitable in clinical applications. In this work, highly porous HA ceramic scaffolds are first produced by the polymer impregnation approach, and subsequently further sintered by hot isostatic pressing (HIP). The phase composition, macro- and micro-porous structure, sintering and mechanical properties of the porous HA scaffolds are investigated by x-ray diffraction (XRD), scanning electron microscopy (SEM), nanoindentation analysis and compressive test. The experimental results show that the nanohardness and compressive strength of HIP-sintered porous HA ceramics are higher than those of commonly sintered HA scaffolds. The HIP technique can effectively improve the sintering property and densification of porous HA ceramic scaffolds, so inducing an increase in the compression strength

  7. Getting the most neutrinos out of IsoDAR

    Energy Technology Data Exchange (ETDEWEB)

    Ciuffoli, Emilio; Zhao, Fengyi; Deliyergiyev, Maksym [CAS, Institute of Modern Physics, Lanzhou (China); Mohammed, Hosam; Evslin, Jarah [CAS, Institute of Modern Physics, Lanzhou (China); University of the Chinese Academy of Sciences, Beijing (China)

    2017-12-15

    Several experimental collaborations worldwide intend to test sterile neutrino models by measuring the disappearance of antineutrinos produced via isotope decay at rest (IsoDAR). The most advanced of these proposals have very similar setups, in which a proton beam strikes a target yielding neutrons which are absorbed by a high isotopic purity {sup 7}Li converter, yielding {sup 8}Li whose resulting decay yields the antineutrinos. In this note, we use FLUKA and GEANT4 simulations to investigate three proposed modifications of this standard proposal. In the first, the {sup 7}Li is replaced with {sup 7}Li compounds including a deuterium moderator. In the second, a gap is placed between the target and the converter to reduce the neutron bounce-back. Finally, we consider cooling the converter with liquid nitrogen. We find that these modifications can increase the antineutrino yield by as much as 50%. The first also substantially reduces the quantity of high purity {sup 7}Li which is needed. (orig.)

  8. ISO Guest Observer Data Analysis and LWS Instrument Team Activities

    Science.gov (United States)

    Smith, Howard

    2001-01-01

    The following is an interim annual report. Dr. Smith is currently on an extended TDY to the Istituto di Fisica dello Spazio Interplanetario (IFSI) at the Consilio Nazionale delle Richerche (CNR) in Rome, Italy, where he has been working on a related NASA grant in support of analysis of Infrared Space Observatory (ISO) data on star formation in Ultra Luminous Infrared Galaxies and our galaxy. Work emphasizes development of metal mesh grids for use in spacecraft, and the design and fabrication of test elements by the Naval Research Laboratory, Washington D.C. Work has progressed well, but slowly, on that program due to the departure of a key engineer. NASA has been advised of the delay, and granted a no-cost extension, whereby SAO has authorized a delay in the final report from NRL. Nevertheless NRL has continued to make progress. Two papers have been submitted to refereed journals related to this program, and a new design for mesh operating in the 20-40 micron region has been developed. Meetings continue through the summer on these items. A new technical scientist has been made a job offer and hopefully will be on board NRL shortly, although most of the present grant work is already completed. A more complete report, with copies of the submitted papers, designs, and other measures of progress, will be submitted to NASA in September when Dr. Smith returns from his current TDY.

  9. ENERGY MANAGEMENT SYSTEMS AND ISO 50001 ACCREDITATION IN SHIPPING

    Directory of Open Access Journals (Sweden)

    BRANISLAV DRAGOVIŠ

    2017-12-01

    Full Text Available The shipping sector is facing new challenges in energy consumption and management. In a recent study conducted by the European Sea Ports Organization (ESPO has shown that energy consumption has risen from 7th place in 2009, to 2nd in 2016, as far as the 10 environmental priorities of European ports. Energy management is seen as the greatest risk for shipping companies, due to the variability existing in the oil and gas markets, in recent decades. Unsuccessful energy management strategies have been shown to have serious consequences for the natural environment, as well as for the companies themselves, which include the enhancement of global warming, and the destruction of a positive corporate image/reputation. Due to this, shipping companies now consider energy as an integral part of their overall strategy and adopt risk management assessments in order to attain the best returns on their investments. The ISO 50001 standard provides a useful tool to companies that are eager to develop and apply an efficient energy strategy consistent with modern Social Corporate Responsibility requirements and aspirations.

  10. Detailed validation in PCDDF analysis. ISO17025 data from Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Kernick Carvalhaes, G.; Azevedo, J.A.; Azevedo, G.; Machado, M.; Brooks, P. [Analytical Solutions, Rio de Janeiro (Brazil)

    2004-09-15

    When we define validation method we can use the ISO standard 8402, in reference to this, 'validation' is the 'confirmation by the examination and supplying of objective evidences that the particular requirements for a specific intended use are fulfilled'. This concept is extremely important to guarantee the quality of results. Validation method is based on the combined use of different validation procedures, but in this selection we have to analyze the cost benefit conditions. We must focus on the critical elements, and these critical factors must be the essential elements for providing good properties and results. If we have a solid validation methodology and a research of the source of uncertainty of our analytical method, we can generate results with confidence and veracity. When analyzing these two considerations, validation method and uncertainty calculations, we found out that there are very few articles and papers about these subjects, and it is even more difficult to find such materials on dioxins and furans. This short paper describes a validation and uncertainty calculation methodology using traditional studies with a few adaptations, yet it shows a new idea of recovery study as a source of uncertainty.

  11. Ignition studies of n-heptane/iso-octane/toluene blends

    KAUST Repository

    Javed, Tamour

    2016-07-09

    Ignition delay times of four ternary blends of n-heptane/iso-octane/toluene, referred to as Toluene Primary Reference Fuels (TPRFs), have been measured in a high-pressure shock tube and in a rapid compression machine. The TPRFs were formulated to match the research octane number (RON) and motor octane number (MON) of two high-octane gasolines and two prospective low-octane naphtha fuels. The experiments were carried out over a wide range of temperatures (650–1250 K), at pressures of 10, 20 and 40 bar, and at equivalence ratios of 0.5 and 1.0. It was observed that the ignition delay times of these TPRFs exhibit negligible octane dependence at high temperatures (T > 1000 K), weak octane dependence at low temperatures (T < 700 K), and strong octane dependence in the negative temperature coefficient (NTC) regime. A detailed chemical kinetic model was used to simulate and interpret the measured data. It was shown that the kinetic model requires general improvements to better predict low-temperature conditions and particularly requires improvements for high sensitivity (high toluene concentration) TPRF blends. These datasets will serve as important benchmark for future gasoline surrogate mechanism development and validation. © 2016 The Combustion Institute

  12. Understanding the LCA and ISO water footprint: A response to ...

    Science.gov (United States)

    Water footprinting has emerged as an important approach to assess water use related effects from consumption of goods and services. Assessment methods are proposed by two different communities, the Water Footprint Network (WFN) and the Life Cycle Assessment (LCA) community. The proposed methods are broadly similar and encompass both the computation of water use and its impacts, but differ in communication of a water footprint result. In this paper, we explain the role and goal of LCA and ISO-compatible water footprinting and resolve the six issues raised by Hoekstra (2016) in “A critique on the water-scarcity weighted water footprint in LCA”. By clarifying the concerns, we identify both the overlapping goals in the WFN and LCA water footprint assessments and discrepancies between them. The main differing perspective between the WFN and LCA-based approach seems to relate to the fact that LCA aims to account for environmental impacts, while the WFN aims to account for water productivity of global fresh water as a limited resource. We conclude that there is potential to use synergies in research for the two approaches and highlight the need for proper declaration of the methods applied. This paper advances efforts to understand ways to accurately capture use of water in life cycle analysis in other contexts. As the paper indicates, there is a discussion about whether quantities of water should be weighted by some local stress factor. This paper attempts to brid

  13. Catalytic cracking of iso-hexene over sapo-34 catalyst

    International Nuclear Information System (INIS)

    Nawaz, Z.; Shu, Q.

    2009-01-01

    The catalytic cracking of model feed compound, iso-hexene (2-methyl-1-pentene) was experimentally studied over 100% pure SAPO-34 zeolite catalyst. The critical focus was given to obtain maximum propylene selectivity. The product distributions were analyzed at temperature between 450-600 degree C. time-on-stream (TOS) from 1 to 5 min. and at WHSV = 7.9 h/sub -1/ The reaction behavior was quantified on both direct and indirect carbenium ion mechanisms owing to catalyst's small pore diameter with respect to 2-methyl-l-pentene kinetic diameter. The propylene yield and selectivity obtained was 41.2% and 43.1% respectively. with higher overall olefins selectivity 90.3%. The small pore size and week surface acid sites of 1000 percent pure SAPO-34 catalyst were found to be suitable for light olefins production and eliminate chances of bimolecular reactions. It was observed that both conversion and selectivity were strongly effected by TOS, as coke precursors become dominant and deactivate catalyst at higher TOS. (author)

  14. Separating Iso-Propanol-Toluene mixture by azeotropic distillation

    Science.gov (United States)

    Iqbal, Asma; Ahmad, Syed Akhlaq

    2018-05-01

    The separation of Iso-Propanol-Toluene azeotropic mixture using Acetone as an entrainer has been simulated on Aspen Plus software package using rigorous methods. Calculations of the vapor-liquid equilibrium for the binary system are done using UNIQUAC-RK model which gives a good agreement with the experimental data reported in literature. The effects of the Reflux ratio (RR), distillate-to-feed molar ratio (D/F), feed stage, solvent feed stage, Total no. of stages and solvent feed temperature on the product purities and recoveries are studied to obtain their optimum values that give the maximum purity and recovery of products. The configuration consists of 20 theoretical stages with an equimolar feed of binary mixture. The desired separation of binary mixture has been achieved at the feed stage and an entrainer feeding stage of 15 and 12 respectively with the reflux ratios of 2.5 and 4.0, and D/F ratio of 0.75 and 0.54 respectively in the two columns. The simulation results thus obtained are useful to setup the optimal column configuration of the azeotropic distillation process.

  15. Securing a control system: experiences from ISO 27001 implementation

    International Nuclear Information System (INIS)

    Vuppala, V.; Vincent, J.; Kusler, J.; Davidson, K.

    2012-01-01

    Recent incidents of breaches, in control systems in specific and information systems in general, have emphasized the importance of security and operational continuity in achieving the quality objectives of an organization, and the safety of its personnel and infrastructure. However, security and disaster recovery are either completely ignored or given a low priority during the design and development of an accelerator control system, the underlying technologies, and the overlaid applications. This leads to an operational facility that is easy to breach, and difficult to recover. Retrofitting security into a control system becomes much more difficult during operations. In this paper we describe our experiences with implementing ISO/IEC 27001 Standard for information security at the Electronics Department of the National Superconducting Cyclotron Laboratory (NSCL) located on the campus of Michigan State University. We describe our risk assessment methodology, the identified risks, the selected controls, their implementation, and our documentation structure. We also report the current status of the project. We conclude with the challenges faced and the lessons learnt. (authors)

  16. [Certification according to ISO 9001--waste of time or necessity?].

    Science.gov (United States)

    Metz-Schimmerl, S; Schima, W; Herold, C J

    2002-05-01

    Quality management (QM) systems are widely established management tools in the industry and business world today. In the health care sector, the need for quality, the implementation of quality management systems and economic orientation of the hospital management are strongly encouraged. Centers of excellence are created to offer special medical services of the highest possible quality. Furthermore, there is a worldwide tendency to establish standards in clinical medical settings, in teaching profession and medical science. These trends make the implementation of a quality management system in health care system highly desirable. The present manuscript reviews the fundamental principles and concepts and the aims of internationally accepted QM systems. It focuses on the ISO-9000 certificates and the European Foundation of Quality Management (EFQM) model. The advantages and disadvantages are discussed. The resources necessary for installation of a QM system and the different phases of implementation are reported. According to the experience of several groups, QM systems can be reliably used in a radiology department and lead to continuous improvement of the quality of services.

  17. Operation of the ISO-DALT system: Seventh edition

    International Nuclear Information System (INIS)

    Tollaksen, S.L.; Anderson, N.L.; Anderson, N.G.

    1984-05-01

    The ISO-DALT system of two-dimensional electrophoresis was developed as a series of modifications of the original technique of O'Farrell. We have written a series of recipes and more detailed laboratory procedures that incorporate refinements and ''tricks of the trade'' as they have developed during our use of the system. The present collection is the seventh version in this series and represents the state of art as of May 1984. The seventh edition has been prepared to incorporate the changes that we have found helpful, as well as to add a few new sections such as silver staining, transfer gels, ACIDOs, and BASOs. Although these directions are specific for our laboratory, we hope that they will be helpful in other laboratories as well. Although some disagreement still exists, we recommend that gel patterns be oriented with acid isoelectric points (pIs) to the left and high sodium dodecyl sulfate (SDS) molecular weights at the top. This results in a system of pI and molecular weight values that run according to the Cartesian convention and facilitates the use of the charge and molecular weight standards described herein. 67 refs., 14 figs

  18. The ISO 50001 Impact Estimator Tool (IET 50001 V1.1.4) - User Guide and Introduction to the ISO 50001 Impacts Methodology

    Energy Technology Data Exchange (ETDEWEB)

    Therkelsen, Peter L. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Rao, Prakash [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Aghajanzadeh, Arian [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); McKane, Aimee T. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-08-01

    ISO 50001-Energy management systems – Requirements with guidance for use, is an internationally developed standard that provides organizations with a flexible framework for implementing an energy management system (EnMS) with the goal of continual energy performance improvement. The ISO 50001 standard was first published in 2011 and has since seen growth in the number of certificates issued around the world, primarily in the industrial (agriculture, manufacturing, and mining) and service (commercial) sectors. Policy makers in many regions and countries are looking to or are already using ISO 50001 as a basis for energy efficiency, carbon reduction, and other energy performance improvement schemes. The Impact Estimator Tool 50001 (IET 50001 Tool) is a computational model developed to assist researchers and policy makers determine the potential impact of ISO 50001 implementation in the industrial and service (commercial) sectors for a given region or country. The IET 50001 Tool is based upon a methodology initially developed by the Lawrence Berkeley National Laboratory that has been improved upon and vetted by a group of international researchers. By using a commonly accepted and transparent methodology, users of the IET 50001 Tool can easily and clearly communicate the potential impact of ISO 50001 for a region or country.

  19. Providing for transmission in times of scarcity: an ISO cannot do it all

    International Nuclear Information System (INIS)

    Allen, E.; Ilic, M.; Younes, Z.

    1999-01-01

    The main purpose of this paper is to point out issues critical for establishing a good transmission strategy in an energy market. First, it is suggested that a transmission strategy must be discussed in the context of a specific market structure. Responsibilities of a transmission system provider differ fundamentally, depending on the type of energy market it is supposed to serve. To show this, a summary of information assumed to be known to an Independent System Operator (ISO) in three energy market structures is given, i.e., (1) a mandatory ISO, (2) an entirely multilateral market and (3) a voluntary ISO. The differences between these three proposals concerning an ISO's responsibility for achieving systemwide efficiency and fair charges for transmission service, particularly at times of scarcity, are analyzed. It is shown that an ISO equipped with the present types of optimization tools for both reliability and efficiency is generally 'blind' to questions of fairness with respect to the individual market participants when providing transmission system support. In order to get around this problem, much more work will have to he done by the technical and regulatory communities. The only tools at an ISO's disposal at present are used for systemwide objectives, such as systemwide reliability. While some of this work is under way, it will take some time to develop the actual ISO tools necessary for implementing the fairness criterion metrics ('standards'), whichever ones the community arrives at. (Developing metrics of fair reliability contributions for the individual market participants is a nonunique process, and it may be very difficult to actually agree upon). Meanwhile, in order to have an ISO actively help energy markets in a fair and efficient way in realistic markets, which are likely to be voluntary ISOs, a system user must become an active part of decision making, indicating how much it wishes to use the system at times of scarcity and at which price. One

  20. Listen to ISO 9001:2015 for organizational competitiveness: Correlation between change management and improvement

    Directory of Open Access Journals (Sweden)

    Fonseca Luis Miguel

    2017-07-01

    Full Text Available In their quest to achieve superior performance and business results, organizations have extensively adopted models such as ISO 9001 Quality Managements Standards. Research supports that Quality Management System brings significant benefits for organizations competitiveness and success and more than 1 million organizations of all activity sectors worldwide have implemented ISO 9001. In a world of increasingly complexity and interconnection, the revised ISO 9001:2015 International Standard aims to ensure that Quality Management Systems are flexible while remaining reliable. The concept of Change Management was introduced in the standard and Improvement can be achieved both in a continual/incremental mode (already present in the ISO 9001:2008 edition and in a breakthrough change/disruptive mode (new in ISO 9001:2015. ISO 9001:2015 is now closer to Business Excellence Models, such as the EFQM, that highlight the need for agility and flexibility for enduring success. To access if organizations that have already implemented ISO 9001:2015 are indeed managing change and achieving improvement, and if there is a relationship between these two variables, a survey was held with IRCA ISO 9001 Registered Auditors on a worldwide basis. Sample normality was confirmed trough Kolmogorov-Smirnov Test and the hypothesis was tested by using Pearson Correlation coefficient. The findings show that the auditee organizations have positively implemented ISO 9001:2015 requirements on change management and improvement. There is also a strong positive correlation between change management and improvement, suggesting that the organizations that properly manage change by planning, designing, implementing, and controlling change in an effective and efficient way, demonstrate a higher level of performance and results improvement. These conclusions have significant implications for the Quality/Organizational Excellence Management Body of Knowledge, requiring a new way of

  1. Laboratory accreditation complying with ISO 25 Guide (IRAM 301): Industrial radiography method

    International Nuclear Information System (INIS)

    Schneebeli, Jorge E.; Zampini, Juan J.; Naucevich, Alfredo

    2000-01-01

    The ISO 25 Guide (IRAM 301) replaced by ISO 17025 is the standard applied for the implementation of a quality system in a test or calibration laboratory. This document is not known as ISO 9000, but it is the proper standard for this kind of laboratory. This document establishes requirements no just for the quality system in general, but on technical competence, that means the laboratory technical aptitude to carry out the tests. The aim of this paper is to comment the criteria used in the Radiographic Laboratory of CEMEC, that have been assessed by the United King dome Accreditation Service (UKAS). (author)

  2. ISO 13485 a complete guide to quality management in the medical device industry

    CERN Document Server

    Abuhav, Itay

    2011-01-01

    Although complex and lengthy, the process of certification for the ISO 13485 can be easily mastered using the simple method outlined in ISO 13485: A Complete Guide to Quality Management in the Medical Device Industry. Written by an experienced industry professional, this practical book provides a complete guide to the ISO 13485 Standard certification for medical device manufacturing. Filled with examples drawn from the author's experience and spanning different sectors and fields of the medical device industry, the book translates the extra ordinary requirements and objectives of the standard

  3. ISO 9001 laatujärjestelmän liittäminen osaksi ISM manuaalia

    OpenAIRE

    Koskinen, Ville

    2016-01-01

    Lopputyön aiheena on Turkulaisen varustamon VG-Shipping Oy toimeksiantona selvittää ISO 9001 standardin vaatimusten mukaisten ohjeistuksien liittäminen yrityksen voimassa olevaan turvallisuusjohtamisjärjestelmään (ISM) ja yhdistetyn manuaalin rakentaminen vastaamaan molempien standardien (ISM koodi ja ISO 9001 standardi) vaatimuksia, siten että varustamon alukset eivät ole ISO 9001 luokiteltuja vaan ainoastaan ISM koodin mukaan auditoituja. Lopullisena toimenpiteenä on hyväksyttää ja audit...

  4. Can the ISO-standards on quality management be useful to libraries and how?

    DEFF Research Database (Denmark)

    Johannsen, Carl Gustav

    1994-01-01

    The aim of this paper is to discuss whether the ISO 9000 concept of quality assurance is useful in a library context or not. First, the basics of the ISO 9000 series are explained. Then, the nature of the concept is discussed and the critical views raised by quality management experts are reviewed...... concluded that the whole discussion on ISO 9000 seems a little futile because the real critical success factor for libraries aiming at Total Quality does not seem to lie in the choice of a specific quality model or guru but more is a question of commitment project on quality assurance in special libraries...

  5. Correlating the content and context of PAS 55 with the ISO 55000 series

    Directory of Open Access Journals (Sweden)

    Van den Honert, A. F.

    2013-08-01

    Full Text Available The ISO 55000 series is soon to supersede PAS 55 as the most recognised international standard for asset management. A correlation of the content and context of PAS 55 with the ISO 55000 series is required to assist organisations with the transition. After analysis of the structures, similarities, differences, and omissions of the two standards, a map was created to correlate the summarised content and context. The map established that, although both sets of standards have a similar structural framework, the ISO 55000 series is a more comprehensive and detailed standard, creating a clearer way to implement an asset management system within an organisation.

  6. Implementation Of ISO 9000 Quality Management System Within The Manufacturing And Service Industry Of Ivory Coast

    Directory of Open Access Journals (Sweden)

    Borget Alfred Anoye

    2015-08-01

    Full Text Available Abstract The objective of this paper was to present the factors that impede the implementation of ISO 9000 QMS within the manufacturing and service Industry of Ivory Coast. It wasnt the intention of the author to provide detailed strategies for the readers to implement ISO 9000. It was an effort to present the relationship if any between the lack of ISO 9000 adoption and the perception of Ivoirians business organization leaders. For that purpose five research questions were associated with this study. The population for this study was all non-ISO certified business organizations in both public and private sector and was physically located in Ivory Coast. The population sample for this study was the 5044 members of the Chambre de Commerce et dIndustrie de Cote dIvoire CCI from which the author utilized the sample size of 60 business organizations randomly selected. This study utilized a survey questionnaire of face to face interview as data collection method. The survey questionnaire contained thirty three 33 questions organized in six parts and was proposed to 60 business organizations leaders. The result showed that business organization leaders in Ivory Coast were aware of the ISO 900 QMS but do not have enough knowledge on the ISO 9000 QMS implementation and certification. This could be due to the poor job done by CODIMORM the local national bureau of standards as a source of information. However it was found that business organization leaders in Ivory Coast intended to pursue and obtain ISO 9000 QMS certification. With respect to perceived benefits they indicated customer satisfaction improvement as the most important benefit that ISO 9000 QMS certification could bring to their general management activities. With respect to perceived improvements they selected quality of productsservices as the most important improvement that ISO 9000 QMS implementation and certification could help to achieve. Overall business organization leaders in Ivory

  7. Step of quality assurance preparation on ISO 9001:2000 toward certification

    International Nuclear Information System (INIS)

    Agustiar

    2007-01-01

    ISO 9001:2000 is the International Standard for the quality management system that stipulate requirement and recommendation provided for design until product. The standard is also regulated the implementation and evaluation from management system point of view the objective to assure organization will meet specified requirement product. To propose ISO 9001:2000 certification, many steps of action should be carried out. There are 5 primary sections of the quality management system requirements of ISO 9001:2000. Quality Management system, Management responsibility, Resource management, Product realization and Measurement, Analysis and improvement, in which all will be begun with training until evaluation (author)

  8. IMPLEMENTASI ISO 9001: 2000 PADA PEMBELAJARAN PRODUKTIF BIDANG KEAHLIAN BANGUNAN DI SEKOLAH MENENGAH KEJURUAN

    Directory of Open Access Journals (Sweden)

    Riban Riban

    2012-08-01

    Full Text Available The implementation of ISO 9001: 2000 in productive learning of building engineering sector in vocational education. The objtective of this study was to uncover the barriers to implementation of ISO 9001:2000 in productive learning. The study was designed using multisite study design. Tecniques of collecting the data were interview, observation to partici­pants, and documentation test. The result of the study are: (1 Implementation of the ISO 9001: 2000 in productive learning of  building engineering sector relates to the implementation of the concept of P-D-C-A in the ISO quality management system; (2 the barriers in implementation of ISO 9001:2000 in pro­ductive learning include low awareness level, inconsistencies, and disobedience; and (3 efforts to overcome the barriers to implementation of ISO 9001:2000 in produc­tive learning involve building the shared commitment, socialization in order to create together awareness, supervising, and doing the preventive action. Implementasi ISO 9001: 2000 pada Pembelajaran Produktif Bidang Keahlian Bangunan di Sekolah Menengah Kejuruan. Penelitian ini bermaksud meng­ungkap lebih mendalam tentang, imple­men­­­tasi, hambatan-hambatan, dan upaya-upaya dalam mengatasi ham­batan penerap­an ISO 9001: 2000 pada pembelajaran produktif. Penelitian ini diran­cang dengan menggunakan rancangan studi multisitus. Teknik pengum­pulan data meliputi wawan­cara, observasi partisipan, dan studi dokumentasi. Temuan penelitian adalah: (1 Penerapan ISO 9001: 2000 pada pem­belajaran pro­duktif teknik bangunan mengacu pada konsep P-D-C-A ke dalam sistem manajemen mutu ISO; (2 hambatan implementasi ISO 9001: 2000 pada pem­bel­ajaran produktif meliputi tingkat kesadaran rendah, inkonsistensi, dan ketidak­taatasasan; dan (3 upaya mengatasi hambatan dalam implementasi ISO 9001: 2000 pada pembelajar­an produk­tif meliputi membangun komitmen bersama, sosialisasi dalam rangka me­num­buhkan kesadaran bersama

  9. Mejoramiento de la calidad docente, utilización de la norma (ISO-10015 en el CETIS 104 IMPROVEMENT OF TEACHING QUALITY, USE TO ISO 10015 NORM IN CETIS 104

    Directory of Open Access Journals (Sweden)

    Fernández Pérez Jorge Alejandro

    2009-04-01

    Full Text Available Resumen: Con la formación docente, se hace referencia a un proceso de desarrollo más que a un programa de estudios o de aprendizaje que se realiza de manera permanente, y que pasa a través de una serie de etapas para adquirir conocimientos y habilidades. Debido a lo anterior, la formación del docente se presenta como una necesidad para el funcionamiento y desarrollo de cualquier organización educativa.Para este estudio se tomaron en cuenta los principios de gestión de la calidad que respaldan la familia de normas ISO (Organización Internacional de Estándares, que por primera vez ha desarrollado una norma sobre la formación y actualización por competencia laboral en el marco de un sistema de calidad, de la cual forma parte la serie ISO/DIS 10015:1999 que enfatiza la importancia de la gestión del recurso humano y la necesidad de una formación adecuada.El enfoque de la presente investigación fue cuantitativo, con la intención de detectar necesidades específicas de formación y actualización del personal docente del Centro de Estudios Tecnológicos Industrial y de Servicios No. 104 (CETis 104, y a partir de ello establecer los métodos y formas de cómo deberá ser proporcionada la formación y actualización.Abstract: With the teaching training, it made a process reference of development more like a study program or learning that to reach of permanent ways, and what happen through of the stage series to obtain knowledge and abilities’. Because of this, the teaching training its show like a need, wherever other case for the function and develop of the any education organization.For this study it takes the quality management principles than support the family rules ISO (International Standard Organization, that for the beginning has a development one rule over the training and actualization for professional abilities in the quality system framework, to give a part of the series ISO/DIS 10015:1999 than a important emphasize of the

  10. Estudio para la implementación de un sistema integrado de gestión basado en las normas ISO 9001:2008 y OHSAS 18001:2007 en una planta de confecciones

    OpenAIRE

    Zambrano Castillo, Carlos Raimundo; Zambrano Castillo, Carlos Raimundo

    2013-01-01

    El presente informe propone la implementación de un sistema integrado de gestión en materia de calidad y seguridad y salud ocupacional, según los requisitos solicitados en las normas ISO 9001:2008 y OHSAS 18001:2007. Para el efecto se ha desarrollado el manual integrado y los procedimientos comunes y específicos, necesarios para el funcionamiento y mantenimiento del sistema integrado, según el resultado del diagnóstico de cumplimiento del sistema actual de la empresa Libertex S.A., con respec...

  11. PYME y cooperativas ante el reto de la RSE: la nueva ISO 26000 (SMEs and cooperatives confront the challenge of CSR: the new ISO 26000

    Directory of Open Access Journals (Sweden)

    Juan Pablo Landa

    2012-05-01

    Full Text Available Corporate Social Responsibility is a central issue in modern business and a main factor of companies strategies for competitiveness in a global economy . The recent approval of ISO26000 shows this general tendency to introduce social and environmental principles in global governance and organizational behaviour in all kinds of firms, organizations and multinational corporations. This paper offers a critical approach to the effects of ISO 26000 in the small and medium companies, and cooperatives, too. This norm is not focussed on the particularities of this kind of companies and shows some problems when implementing it in SME & social economy organizations. The question which comes up is if there is a necessity to adapt the implementation of ISO 26000 to these particular firms: in which cases and to what limits. La Responsabilidad Social Corporativa es una cuestión central en la economía moderna, y un factor fundamental en las estrategias competitivas de las empresas, en el marco de una economía globalizada. La reciente aprobación de la norma ISO 26000 recoge la tendencia general de introducir principios sociales y medioambientales en el gobierno global y en la organización de todo tipo de empresas, organizaciones y corporaciones multinacionales. Este artículo ofrece un acercamiento crítico a los efectos de la norma ISO 26000 en las PYMEs y cooperativas. Esta norma no contempla las particularidades de este tipo de compañías, y muestra algunos problemas al implantarlas en PYMEs y organizaciones de la economía social. Se cuestiona la necesidad de adaptar la implementación de la norma ISO 26000 a este tipo de organizaciones, en qué casos, y con qué limites.DOWNLOAD THIS PAPER FROM SSRN: http://ssrn.com/abstract=2049865

  12. Removal of Uranium in Drinking Water: Brimac Environmental Services, Inc. Brimac HA 216 Adsorptive Media

    Science.gov (United States)

    The Brimac HA 216 Adsorptive Media was tested for uranium (U) removal from a drinking water source (well water) at Grappone Toyota located in Bow, New Hampshire. The HA 216 media is a hydroxyapatite-based material. A pilot unit, consisting of a TIGG Corporation Cansorb® C-5 ste...

  13. Quality control in the waste water treatment: ISO 9000 in an EDAR; Control de calidad en la depuracion de aguas residuales: ISO 9000 en una EDAR

    Energy Technology Data Exchange (ETDEWEB)

    Marcote Lago, J. M.; Laino Lopez, H.; Moreira Vilar, M. T.; Feijoo Costal, G.

    2002-07-01

    The Quality has been converted into an indispensable tool into the managerial world, considering the high degree of competitiveness of products and associated processes, as well as the increase of the needs and requirements of the consumers. In this article the action are analyzed directed to obtain the quality degree, according to the norm ISO 9000, on the stations of waste water treatment (EDAR). for it, there are established the guidelines of planning of the maintenance in an EDAR, which will redound to an improvement of its management as step before the certification of the norm ISO 9000. (Author) 5 refs.

  14. Exploring the Impact of ISO 9001, ISO 14001 and OHSAS 18001 Certification on Financial Performance: The Case of Companies listed on the Bucharest Stock Exchange

    Directory of Open Access Journals (Sweden)

    Mihaela Ionașcu

    2017-02-01

    Full Text Available The purpose of this paper is to investigate the impact of ISO 9001, ISO 14001 and OHSAS 18001 certification on the financial performance of Romanian companies listed on the Bucharest Stock Exchange (BSE. Based on audited financial statements of a population of 67 non-financial companies listed during 2013-2015 and using regression models, this paper shows, for the first time in Romania, that companies listed on BSE, implementing complex management systems (quality – environmental and/or occupational health and safety perform better, and that their performance is directly linked to the complexity of the management systems implemented.

  15. Implementation of ISO 9000 Quality Standard into Adult Education

    Directory of Open Access Journals (Sweden)

    Andrej Sotošek

    2000-12-01

    Full Text Available Competition in the field of adult education in Slovenia has become very tough  in the second half of the 1990s. Therefore, educational institutions are forced to use every advantage over the competitors in the educational market. One of them is the quality system in educational process. Such competitive position setting strategic development objectives is also the strategy of UPI - Ljudska univerza Žalec. Through development objectives, relationships with our partners and customers, as well as on the basis of analysis of the position and connections of Slovenia within the European Union and its involvement in international projects we estimated that we should set up a quality system in our institution involving managerial, organisational and professional function. It is important that the system should be comparable and verifiable according to the European standards. We have chosen the Quality System according to ISO 9000 quality standards as the most suitable model. It offers an institutional framework as well as a good basis for an internal and external verification of the efficiency of the system in real life. It also enables corrections to deviations. However, it lacks a stronger stress on internal self-control and self-evaluation, which is emphasised in the model of quality assurance in education developed by a group of experts to order of Ministry of Education and Sport. Both model s can be combined and are mutually compatible. I am convinced of the great importance of self-evaluation in education. Yet, without an appropriate institutional framework and basic external verification the self-evaluation remains on the interna! and subjective level of judgement within an individual educational institution.

  16. Post-accelerator issues at the IsoSpin Laboratory

    International Nuclear Information System (INIS)

    Chattopadhyay, S.; Nitschke, J.M.

    1994-05-01

    The workshop on ''Post-Accelerator Issues at the Isospin Laboratory'' was held at the Lawrence Berkeley Laboratory from October 27--29, 1993. It was sponsored by the Center for Beam Physics in the Accelerator and Fusion Research Division and the ISL Studies Group in the Nuclear Science Division. About forty scientists from around the world participated vigorously in this two and a half day workshop, (c.f. Agenda, Appendix D). Following various invited review talks from leading practitioners in the field on the first day, the workshop focussed around two working groups: (1) the Ion Source and Separators working group and (2) the Radio Frequency Quadrupoles and Linacs working group. The workshop closed with the two working groups summarizing and outlining the tasks for the future. This report documents the proceedings of the workshop and includes the invited review talks, the two summary talks from the working groups and individual contributions from the participants. It is a complete assemblage of state-of-the-art thinking on ion sources, low-β, low(q/A) accelerating structures, e.g. linacs and RFQS, isobar separators, phase-space matching, cyclotrons, etc., as relevant to radioactive beam facilities and the IsoSpin Laboratory. We regret to say that while the fascinating topic of superconducting low-velocity accelerator structure was covered by Dr. K. Shepard during the workshop, we can only reproduce the copies of the transparencies of his talk in the Appendix, since no written manuscript was available at the time of publication of this report. The individual report have been catologed separately elsewhere

  17. A Cross-Country Empirical Study Towards the Impact of Following ISO Management System Standards on Euro-Area Economic Confidence

    Directory of Open Access Journals (Sweden)

    Ştefan Daniel Armeanu

    2017-02-01

    Full Text Available This study aims to examine the impact of following ISO management system standards on economic sentiment indicator (ESI as proxy of economic agents’ general view concerning economic activity, for 21 European Union member states over 2005-2014. The empirical research comprises ISO standards with reference to management systems towards quality (ISO 9001, ISO 13485, ISO 16949, food safety (ISO 22000, environment (ISO 14001, and information security (ISO 27001. Panel data fixed effects regression models provide support for a positive impact of the quality management systems related to automotive industry, as well as information security management systems, on the ESI. Further, dynamic panel data approach by way of two-step system generalized method of moments emphasizes a positive influence of quality management systems standard for the medical device industry on Euro-area economic confidence, but a negative effect of food safety management systems. Also, ISO 9001, ISO 22000, and ISO 14001 Granger cause ESI.

  18. FROM QUALITY GURUS AND TQM TO ISO 9001:2015: A REVIEW OF SEVERAL QUALITY PATHS

    Directory of Open Access Journals (Sweden)

    Luís Miguel Fonseca

    2015-03-01

    Full Text Available A revision of several paths for the Quality journey is presented: from Quality Gurus and Total Quality Management (TQM models to the ISO 9000 International Standards Series. Since ISO 9001:2008 is now in the revision process to the expected ISO 9001:2015 version, an analysis is made of he proposed changes and the underlying reasons and the impacts foreseen on the more than 1.3 Million certified organizations. This revision should be a step towards TQM and reflect the changes of an increasingly complex, demanding and dynamic environment, while assuring that complying organizations are able to provide conformity products and services that satisfy their customers. Major benefits are expected such as less emphasis on documentation and new/reinforced approaches: consideration of Organizational Context and (relevant Stakeholders, Risk Based thinking and Knowledge Management. Comments and recommendations are presented for organizations wishing to implement or update their Quality Systems accordingly to ISO 9001:2015.

  19. Behavior of the aggregate wind resource in the ISO regions in the United States

    KAUST Repository

    Gunturu, Udaya

    2015-04-01

    The collective behavior of wind farms in seven Independent System Operator (ISO) areas has been studied. The generation duration curves for each ISO show that there is no aggregated power for some fraction of time. Aggregation of wind turbines mitigates intermittency to some extent, but in each ISO there is considerable fraction of time when there is less than 5% capacity. The hourly wind power time series show benefit of aggregation but the high and low wind events are lumped in time, thus indicating that intermittency is synchronized in each region. The timeseries show that there are instances when there is no wind power in most ISOs because of large-scale high pressure systems. An analytical consideration of the collective behavior of aggregated wind turbines shows that the benefit of aggregation saturates beyond a certain number of generating units asymptotically. Also, the benefit of aggregation falls rapidly with temporal correlation between the generating units.

  20. Correspondence of ISO 9001:2008 with IAEA GS-R-3

    International Nuclear Information System (INIS)

    Kibrit, Eduardo

    2009-01-01

    This article identifies, characterises and analyses International Organisation for Standardisation (ISO) and International Atomic Energy Agency (IAEA) normative requirements for the development and implementation of quality management systems in nuclear organisations. The structures of the applicable standards, ISO 9001:2008 and IAEA GS-R-3, are characterised. The differences and similarities of objective, focus, scope, level of application, structure, vocabulary, management system, management responsibility, resource management, process implementation, measurement, assessment and improvement verified in the applicable standards are deeply reviewed. A correspondence of the applicable standards' requirements is presented topic by topic. A correlation of the applicable standards' requirements is made, showing IAEA GS-R-3 topics that have no correlation with ISO 9001:2008 and ISO 9001:2008 topics that have no correlation with IAEA GS-R-3. Conclusive remarks advise the pros and cons of using one of the applicable standards or the other. (author)

  1. Department of Defense Quality Management Systems and ISO 9000:2000

    National Research Council Canada - National Science Library

    Lucius, Tommie

    2002-01-01

    ...) to the Department of Defense (DoD) quality management system (QMS) in procurement. In particular, the researcher will examine the new standard and its utility for DoD procurement, focusing on changes from the previous ISO 9000 series...

  2. LCA for assessing the environmental performance of a company with the environmental management system ISO 14000

    International Nuclear Information System (INIS)

    Rigamonti, L.; Perotto, E.

    2008-01-01

    The environmental management system is an ordered pattern to treat and manage environmental issues and to improve the environmental performance of companies. It is proposed an example of application of LCA to a manufacturing company with ISO 14000. [it

  3. Environmental Management Systems (EMS ISO 14001 Implementation in Construction Industry: A Malaysian Case Study

    Directory of Open Access Journals (Sweden)

    Sumiani Yusoff

    2015-03-01

    Full Text Available This study seeks to explore the crucial part in EMS implementation; i.e. environmental aspects and impacts, Good Environmental Practice to be developed in construction site, as well as the level of awareness or understanding amongst site staffs on ISO 14001 EMS implementation in their organizations. Data were collected via interviews, surveys and site visits. A number of environmental aspects and impacts, and Good Environmental Practices based on ISO 14001:2004 have been identified. The level of understanding of the site staffs on ISO 14001 EMS requirements has been found to be good except for matters concerning Schedule Waste Management. In conclusion, the successful implementation of ISO 14001 EMS mainly depends on staffs‘ understanding.

  4. Department of Defense Quality Management Systems and ISO 9000:2000

    National Research Council Canada - National Science Library

    Lucius, Tommie

    2002-01-01

    The purpose of the research is to examine and evaluate the emergence of the International Organization for Standardization, commonly referred to as ISO, quality standard for the year 2000 as it applies (past and present...

  5. Quality standards: Comparison between IAEA 50-C/SG-Q and ISO 9001:2000

    International Nuclear Information System (INIS)

    2002-01-01

    The International Atomic Energy Agency (IAEA) has the statutory mandate to seek to accelerate and enlarge the contribution of atomic energy to peace, health and prosperity throughout the world. As part of the activities to achieve its objectives, the IAEA is authorized to establish standards of safety for the protection of health and the minimization of danger to life and property. The standards of safety developed by the IAEA are recommendations for use by its Member States in the framework of national regulations for the safe utilization of nuclear energy. Such standards should be considered as nuclear safety regulatory documents. The standards developed by the International Organization for Standardization (ISO) are complementary technical documents emphasizing industrial application and contractual aspects. Regarding the quality assurance topic, the IAEA developed the publication Safety Series No. 50-C/SG-Q, Quality Assurance for Safety in Nuclear Power Plants and other Nuclear Installations, which is mostly used directly or indirectly to establish the nuclear safety requirements at the nuclear utility-regulator interface. The ISO 9001:2000 standard, Quality Management Systems Requirements, is often used to define the quality management system requirements at the utility-supplier interface. The relationship between the IAEA and ISO quality standards is growing in significance owing to their increasing impact upon utilities (owners/operators of nuclear facilities) and their contractors/suppliers. The relationship between the IAEA and ISO standards is considered critical in particular with respect to contractors/suppliers with a small range of nuclear supplies. These contractors-suppliers are not always willing to prepare special quality assurance programmes based on nuclear safety standards. On the other hand, these contractors/suppliers may be qualified on the basis of the ISO quality standard. In any case, for delivering nuclear items and services the

  6. Competence Requirements of ISO/IEC Standards for Information Security Professionals

    Directory of Open Access Journals (Sweden)

    Natalia G. Miloslavskaya

    2017-11-01

    Full Text Available The rapid progress in the filed of information security (IS puts one in a need of periodic revision of professional competencies (formulated in the federal state educational standards –FSESs and working functions (formulated in the professional standards – PSs. Under these conditions, a timely reaction to everything new that emerges or will appear in modern regulatory documents (primarily in standards is extremely important. We make a forecast for the content of the ISO/IEC 27021 and ISO/IEC 19896 standards drafted by the International Organization for Standardization (ISO, which should contain the requirements for the competencies of IS management system professionals and the competence of IS testers and evaluators. Our forecast takes into account the requirements of the ISO/IEC 27000 standard group and the recommendations of the European e-Competence Framework e-CF 3.0.

  7. Behavior of the aggregate wind resource in the ISO regions in the United States

    KAUST Repository

    Gunturu, Udaya; Schlosser, Clemens Adam

    2015-01-01

    The collective behavior of wind farms in seven Independent System Operator (ISO) areas has been studied. The generation duration curves for each ISO show that there is no aggregated power for some fraction of time. Aggregation of wind turbines mitigates intermittency to some extent, but in each ISO there is considerable fraction of time when there is less than 5% capacity. The hourly wind power time series show benefit of aggregation but the high and low wind events are lumped in time, thus indicating that intermittency is synchronized in each region. The timeseries show that there are instances when there is no wind power in most ISOs because of large-scale high pressure systems. An analytical consideration of the collective behavior of aggregated wind turbines shows that the benefit of aggregation saturates beyond a certain number of generating units asymptotically. Also, the benefit of aggregation falls rapidly with temporal correlation between the generating units.

  8. EFFICIENCY OF ISO 9001 IN PORTUGAL: A QUALITATIVE STUDY FROM A HOLISTIC THEORETICAL PERSPECTIVE

    Directory of Open Access Journals (Sweden)

    Alcina Dias

    2013-03-01

    Full Text Available The purpose of this paper is to analy se the efficiency of ISO 9001 from a holistic theoretical approach where the Contingency theory, the Institutional theory and the Resources-Based View are integrated. The study was carried out in companies of different sectors of activity in Portugal, based on a qualitative methodology (interviews. The fact of the interviews having been undertaken under an ISO 9001 structure made it easier for companies to grasp the issues under investigation. An ISO 9001 characterisation was carried out on a theoretical framework approach and findings point out efficiency gains and revealed that the absence of ISO 9001 would work as a competitive disadvantage. The contribution of this research aims to reinforce the state of art as concerns the theoretical scope of analysis of these issues enriched by the case study achievement.

  9. Novel implementation of an ISO standard method for primary vibration calibration by laser interferometry

    CSIR Research Space (South Africa)

    Veldman, CS

    2003-01-01

    Full Text Available -11. The signal processing required for the successful implementation of this method of ISO 16063-11 has been implemented by various metrology institutes using various techniques. For the implementation of these techniques, different hardware and software...

  10. [Quality assurance and certification of a hemodialysis unit according to the ISO-9001-2000 standards].

    Science.gov (United States)

    Arenas, M D; Gil, M T; Egea, J J; Sirvent, A E; Giménez, A

    2003-01-01

    We report the experience of three hemodialysis centers registered with the ISO 9001-2000 standard, regarding the development of a quality measure system and providing an analysis of this system and its advantages and disadvantages.

  11. Manufacturing of microcomponents in a research institute under DIN EN ISO 9001

    Science.gov (United States)

    Maas, Dieter; Karl, Bernhard; Saile, Volker; Schulz, Joachim

    2000-08-01

    The Institute for Microstructure Technology at Forschungszentrum Karlsruhe has implemented a rigorous quality management system and was certified according to the DIN ISO EN 9001 standard in January 2000.

  12. ISO 9000 and 10CFR50, appendix B-one, both, or neither?

    International Nuclear Information System (INIS)

    Nau, D.C.; Hunt, G.L.

    1993-01-01

    The evolution of quality system requirements has led to the development of standards that either have been tailored for use in specific industries (as in the case of 10CFR50, Appendix B) or have been made generic for use in commercial operations (as in the case of the ISO 9000 series of standards). The elements of many quality systems are shared to a large degree, and the requirements of the standards only generally differ in certification, training, and documentation requirements. The proof of conformance to the requirements of 10CFR50, Appendix B, and ISO 9001 is in large part identical. Table I provides an example of the quality elements common between 10CFR50, Appendix B, and ISO 9001. Substantive proof that a supplier's qualification system meets the requirements of 10CFR50, Appendix B, can substantially be used as proof of conformance to ISO 9001

  13. [Quality management according to DIN EN ISO 9001 at a university eye hospital].

    Science.gov (United States)

    Schönherr, U; Händel, A; Naumann, G O

    2001-02-01

    Quality assurance is an integral part of modern microsurgical ophthalmology. Health care laws also mandate overall quality management. In recent years we have standardized the preexisting features of quality management according DIN EN ISO 9001 and have integrated previously missing features. Establishing quality management according to ISO 9001 is possible even at a university eye hospital and department of ophthalmology. Certification according to ISO 9001 specifications was granted in April 1999. The major difficulty was in translating industrial norms to the context of an eye hospital. It was also difficult to overcome skepticism towards quality-assurance measures that lie beyond ophthalmological quality control. It is useful and feasible to establish a quality management system at German university eye hospitals and departments of ophthalmology. Certification according to ISO 9001 is one possibility to make a quality management system transparent and evaluable both inside and outside the hospital.

  14. Corporate environmental policy statements in mainland China: to what extent do they conform to ISO 14000 documentation?

    Science.gov (United States)

    Chung, Shan Shan; Fryxell, Gerald E; Lo, Carlos W H

    2005-04-01

    For decades, industry has been the main source of pollution in China. Determined to make changes, the mainland Chinese authorities have decided to promote mechanisms that incorporate environmental concerns into the internal management of enterprises. This is manifested in the rapid adoption of the ISO14000 standards, including a significant increase in ISO14001 registrations in China. Thus, this study examined the environmental policy statements of 106 certified facilities in mainland China against a strict interpretation of the mandatory requirements of the ISO 14001:1996 standard and the nonmandatory ISO14004 requirements in order to shed some light on the implementation of environmental management systems in an emerging economic giant. It was decided to analyze the environmental policy statement because such a statement is a core element in the ISO system of environmental management of each facility and there are relatively clear and specific requirements on what an environmental policy statement shall include. An analysis of the contents of the environmental policy statements shows that conformance to the relevant requirements of both the mandatory ISO14001 standard and the nonmandatory ISO14004 standard is far from impressive and that the facilities in our sample seldom went beyond the minimum requirements. By using ISO14001 and ISO14004 conformance scores as the dependent variables, we found that conformity to ISO14001 and overall conformance to ISO14000 series can be explained to some extent by the degree of top management commitment, the experience with informal environmental management systems, and the form of ownership of the facilities.

  15. Antigenic properties of a transport-competent influenza HA/HIV Env chimeric protein

    International Nuclear Information System (INIS)

    Ye Ling; Sun Yuliang; Lin Jianguo; Bu Zhigao; Wu Qingyang; Jiang, Shibo; Steinhauer, David A.; Compans, Richard W.; Yang Chinglai

    2006-01-01

    The transmembrane subunit (gp41) of the HIV Env glycoprotein contains conserved neutralizing epitopes which are not well-exposed in wild-type HIV Env proteins. To enhance the exposure of these epitopes, a chimeric protein, HA/gp41, in which the gp41 of HIV-1 89.6 envelope protein was fused to the C-terminus of the HA1 subunit of the influenza HA protein, was constructed. Characterization of protein expression showed that the HA/gp41 chimeric proteins were expressed on cell surfaces and formed trimeric oligomers, as found in the HIV Env as well as influenza HA proteins. In addition, the HA/gp41 chimeric protein expressed on the cell surface can also be cleaved into 2 subunits by trypsin treatment, similar to the influenza HA. Moreover, the HA/gp41 chimeric protein was found to maintain a pre-fusion conformation. Interestingly, the HA/gp41 chimeric proteins on cell surfaces exhibited increased reactivity to monoclonal antibodies against the HIV Env gp41 subunit compared with the HIV-1 envelope protein, including the two broadly neutralizing monoclonal antibodies 2F5 and 4E10. Immunization of mice with a DNA vaccine expressing the HA/gp41 chimeric protein induced antibodies against the HIV gp41 protein and these antibodies exhibit neutralizing activity against infection by an HIV SF162 pseudovirus. These results demonstrate that the construction of such chimeric proteins can provide enhanced exposure of conserved epitopes in the HIV Env gp41 and may represent a novel vaccine design strategy for inducing broadly neutralizing antibodies against HIV

  16. [Nine-Year Experience after ISO 15189 Acquisition, How Successful was It? Focusing on the Results of Interviews and Questionnaires].

    Science.gov (United States)

    Fujimoto, Kazumitsu; Asai, Noriaki; Nakajima, Yoshinaga; Inoue, Kaoru

    2015-11-01

    Our laboratory, for the purpose of Quality Management System (QMS) improvement, acquired ISO 15189:2003 accreditation 9 years ago and completed the renewal to ISO 15189:2012 last year. In this study, we reviewed the efficacy of ISO 15189 based on an analysis of laboratory director's and managers' opinions. We could realize QMS improvement through the proactive implementation of preventive and corrective actions, and also the continuous implementation of education and delivery by means of reviewing the interview records of ISO 15189:2012 renewal with the laboratory director. All answers to the questionnaire obtained from managers with regard to the advantages of ISO 15189 acquisition agreed with the purpose of ISO 15189. From these results, we concluded that ISO 15189 acquisition was successful for QMS improvement. [Review].

  17. Management system quality of service radio physics and RR. ISO 9001

    International Nuclear Information System (INIS)

    Gil Agudo, A.; Torres Donaire, J.; Jimenez, J. C.; Carrascosa Fernandez, C.; Arjona Gutierrez, J.

    2011-01-01

    One of the tool increasingly deployed for the optimization of the procedures is the process management system according to a Quality Management. Likewise, for specific areas, such as central services within large institutions such as the General Hospitals of the systems of quality management is the most widely used ISO 9001. We describe in this paper our experience in implementing the system ISO 9001 in our Department of Radio physics and Radiation Protection (SRFPR).

  18. Impact of Supplier Management Strategies on the Organizational Performance of ISO 9001 Certified Organizations

    OpenAIRE

    Fonseca, Luis Miguel; Lima, Vanda Marlene

    2015-01-01

    Purpose: The purpose of this article is to discuss the impact of Supplier orientation and the resulting Supply Chain Management (SCM) approach, on the organizational performance of ISO 9001 Quality Management Systems certified organizations. Methodology/Approach: Following a literature review, a full structural conceptual model was proposed. An online survey was administered to managers of Portuguese organizations with certified ISO 9001 Quality Management Systems. Descriptive Statistics a...

  19. An iso-erodent map Imo state of Nigeria | Madubuike | International ...

    African Journals Online (AJOL)

    Among inputs/resources often needed for erosion risk assessment of a region is the iso-erodent map of the region. This is a map showing areas of equal erosion potentials in the region. As Imo and Abia states of Nigeria lie in a high erosion region of the country, it was decided in this work to produce an iso-erodent map of ...

  20. Impact of 50% Synthesized Iso-Paraffins (SIP) on F-76 Fuel Coalescence

    Science.gov (United States)

    2013-12-16

    petroleum JP-5 and Synthesized Iso-Paraffins (SIP). SIP fuels are made from direct fermentation of sugar into olefinic hydrocarbons. The olefinic...manufactured scaled down filter/coalescer and separator to simulate the performance of a full-scale filter separator system. This test is designed to predict...5 and Synthesized Iso-Paraffins (SIP). SIP fuels are made from direct fermentation of sugar into olefinic hydrocarbons. The olefinic hydrocarbons

  1. Applying the ISO 9126 Model to the Evaluation of an E-learning System in Iran

    OpenAIRE

    Hossein Pedram; Davood Karimzadegan Moghaddam; Zhaleh Asheghi

    2012-01-01

    One of the models presented in e-learning quality system field is ISO 9126 model, which applied in this research to evaluate e-learning system of Amirkabir University. This model system for evaluation, the six main variables provided that each of these variables by several other indicators was measured. Thus, the model parameters as ISO 9126 and turned the questionnaire survey among samples (120 experts and students of Amirkabir University) and the distribution were completed. Based on the re...

  2. ISO STANDARD IN THE FIELD OF LEARNING SERVICES AND THE PROSPECT OF ITS APPLICATION IN RUSSIA

    Directory of Open Access Journals (Sweden)

    Galina Pankina

    2015-11-01

    Full Text Available The article considers peculiarities and the prospect of the practical implementation of a rather new standard developed by ISO and adopted in Russia. The objective of ISO 29990:2010 is to provide a generic model for quality professional practice and performance, and a common reference for learning service providers and their clients in the design, development and delivery of non-formal education and training.

  3. Pengaruh Sistem Manajemen Iso 9001:2008 Terhadap Pelayanan Kefarmasian Di Puskesmas Kabupaten Sleman

    OpenAIRE

    Aji Wibowo, Much Ilham Novalisa; Munawaroh, Siti; Purnama, Cahya

    2015-01-01

    The vision of health development organized by the district health center is achieving district healthy. The need for improving the quality of health services in health centers contained in the WHO Annual Report 2008 under the title "Primary Health Care, Now More Than Ever". The efforts to improve the quality of services in health centers is ISO 9001:2008 certification at the International level. ISO 9001 certification is expected to improve the quality of pharmacy services at health centers. ...

  4. Perbandingan Tingkat Keberhasilan Terapi Tuberkulosis Pada Puskesmas Yang Sudah Bersertifikat Iso Dan Tidak Di Kabupaten Purbalingga

    OpenAIRE

    Patmiatun, Patmiatun; Hasanmihardja, Moeslich; Utaminingrum, Wahyu

    2011-01-01

    Tuberculosis is a kind of disease caused by Mycobacterium tuberculosis basille. It belongs to the third most of the deadly disease after Cardiovaskuler and Respiration disease, while the first deadly disease comes from infection disease group. The aim of this research is to know the succesfull level of tuberculosis therapy between ISO certified Puskesmas (Puskesmas Padamara) and ISO uncertified puskesmas (Puskesmas Serayu Larangan) by using the succesfull indicator and the comparison of TBC...

  5. Plan de implementación de la ISO/IEC 27001:2013

    OpenAIRE

    Gorriti Aranguren, Iñaki

    2015-01-01

    En el desarrollo del proyecto se analizaron las directrices establecidas en la norma ISO/IEC 27001:2013, que especifica los requisitos necesarios para establecer, implantar, mantener y mejorar un SGSI mediante un proceso de mejora continua. In the development there were analyzed the directives established in the norm ISO/IEC27001:2013, which specifies the necessary requirements to establish, to implement, to support and to improve a SGSI by means of a process of constant improvement. En...

  6. Motivational factors for the adoption of ISO 9001 standards in Eastern Europe: the case of Bulgaria

    Directory of Open Access Journals (Sweden)

    Svetoslav Georgiev

    2015-05-01

    Full Text Available Purpose: This study analyzes the motivational factors for ISO 9001 certification in Bulgaria from the internal/external motivations perspective, or the so-called dual model.Design/methodology/approach: This study is based on a mixed method research approach, which employed two interviews with experts in the field of quality management at the exploratory stage, and a survey involving 127 companies at the descriptive stage.Findings: This study claims that enhanced company image and competitiveness – an external motivation - is the leading motivational factor for ISO 9001 certification in Bulgaria. At the same time, our primary investigation reveals that Bulgarian firms are not predominantly externally driven, for internal motivations including process improvement and product quality improvement seem to be an important driver for ISO 9001 certification. Last but not least, this research asserts that enhanced company image and competitiveness has a stronger impact on the motivations for ISO 9001 certification than customer and supplier pressure, which is in line with previous research works on developing economy economies such as Bulgaria. Finally, our study indicates a moderate, yet positive correlation between motivations for and benefits of ISO 9001 certification.Social implications: This research work casts some light on the evolution of quality management in Bulgaria since the end of communism, which can serve as an important foundation for the better understanding of quality management in former communist economies in general and Eastern European states in particular.Originality/value: Derived from the acute gap between ISO studies in Western and former communist economies, this research work presents one of the first official, international studies in the field of ISO certification in Bulgaria, and more precisely, a paper describing the motives for ISO 9001 certification among Bulgarian businesses.

  7. The process of implementing an ISO 9001 quality management system in a school of nursing.

    Science.gov (United States)

    Lett, M

    2000-01-01

    This paper documents the process undertaken during the establishment of an ISO 9000 series quality management system by a School of Nursing. Further discussion centres around the reasons why an ISO quality management system was implemented, the lessons learnt during the process and the benefits that accreditation has brought to the School of Nursing. The lessons learnt during the process could be of help to other organisations wishing to achieve a similar accreditation status.

  8. Comparison of Hospital standards with ISO principles and presentation appropriate model of Hospital standard development

    Directory of Open Access Journals (Sweden)

    bahram Delgoshai

    2005-02-01

    Conclusion: Writing method of evaluation items in »B hand out« has significant difference with what is done in ISO audit. Research findings showed that in spite of leaping that »B hand out« developing had in national. There are serious lacks in hospital compelete evaluaton so that consider a hospitals system, means and content beacause of lack of enough experiment in standard development based on ISO principles.

  9. Integration of distributed plant lifecycle data using ISO 15926 and Web services

    International Nuclear Information System (INIS)

    Kim, Byung Chul; Teijgeler, Hans; Mun, Duhwan; Han, Soonhung

    2011-01-01

    Highlights: → The ISO 15926 parts that provide implementation methods are under development. → A prototype of an ISO 15926-based data repository called a facade was implemented. → The prototype facade has the advantages of data interoperability and integration. → These are obtained through the features of ISO 15926 and Web services. - Abstract: Considering the financial, safety, and environmental risks related to industrial installations, it is of paramount importance that all relevant lifecycle information is readily available. Parts of this lifecycle information are stored in a plethora of computer systems, often scattered around the world and in many native formats and languages. These parts can create a complete, holistic set of lifecycle data only when they are integrated together. At present, no software is available that can integrate these parts into one coherent, distributed, and up-to-date set. The ISO 15926 standard has been developed, and in part is still under development, to overcome this problem. In this paper, the authors discuss a prototype of an ISO 15926-based data repository called a facade, and its Web services are implemented for storing the equipment data of a nuclear power plant and servicing the data to interested organizations. This prototype is for a proof-of-concept study regarding the ISO 15926 parts that are currently under development and that are expected to provide implementation methods for the integration of distributed plant systems.

  10. [ISO 15189 accreditation in clinical microbiology laboratory: general concepts and the status in our laboratory].

    Science.gov (United States)

    Akyar, Işin

    2009-10-01

    One important trend in the laboratory profession and quality management is the global convergence of laboratory operations. The goal of an accredited medical laboratory is to continue "offering useful laboratory service for diagnosis and treatment of the patients and also aid to the health of the nation". An accredited clinical laboratory is managed by a quality control system, it is competent technically and the laboratory service meets the needs of all its patients and physicians by taking the responsibility of all the medical tests and therapies. For this purpose, ISO 15189 international standard has been prepared by 2003. ISO 15189 standard is originated from the arrangement of ISO 17025 and ISO 9001:2000 standards. Many countries such as England, Germany, France, Canada and Australia have preferred ISO 15189 as their own laboratory accreditation programme, meeting all the requirements of their medical laboratories. The accreditation performance of a clinical microbiology laboratory is mainly based on five essential points; preanalytical, analytical, postanalytical, quality control programmes (internal, external, interlaboratory) and audits (internal, external). In this review article, general concepts on ISO 15189 accreditation standards for the clinical microbiology laboratories have been summarized and the status of a private laboratory (Acibadem LabMed, Istanbul) in Turkey has been discussed.

  11. Nanotechnology Standardization Activities – Support of U.S. Representation on ISO/TC 229 Nanotechnologies

    Energy Technology Data Exchange (ETDEWEB)

    Benko, Heather [American National Standards Inst. (ANSI), Washington, DC (United States)

    2017-03-14

    In carrying out its responsibilities on behalf of the United States, ANSI provides comprehensive, administrative support and expertise on international protocols and procedures to: (1) the U.S. Technical Advisory Group (TAG) to the International Organization for Standardization’s (ISO) Technical Committee (TC) 229 Nanotechnologies, and (2) the corresponding U.S. TAG Working Groups tasked with formulating U.S. positions on topics relevant to nanotechnology standardization. Additionally, secretariat and procedural support is provided for the ISO/TC 229 WG 3 on health, safety and environment, for which the United States was assigned leadership by the participating national body members of ISO/TC 229. As the official entity that serves as the U.S. representative to ISO, ANSI provides not only expert coordination of U.S. positions and representation at ISO but also strategic direction, advice and procedural expertise to facilitate navigation of international issues to promote U.S. positions for incorporation into the ISO/TC 229 program of work necessary to support U.S. objectives.

  12. PERBANDINGAN IMPLEMENTASI ISO DAN PELUNCURAN ENTERPRISE RESOURCES PLANNING TERHADAP INDEKS KINERJA KEUANGAN

    Directory of Open Access Journals (Sweden)

    Sautma Ronni Basana

    2017-03-01

    Full Text Available Recently, companies implemented projects which applied on companies’ overall system. These recent bestpractices of pursuing companies’ effectiveness and efficiency would be implementation of ISO 9000 and ERP.Previous research showed that these two projects could bring benefits for these companies which implementedit. However, it had not been compared which project would bring more benefits to these companies. Thisresearch observed 35 companies which consisted of 15 companies in food and beverages industry, 9 companiesin pharmaceutical industry, 4 companies in cigarettes industry, 4 companies in cosmetics industry, and 3companies in household appliances industry. The data were taken by observing and recording the valueswhich related to COGS (cost of goods sold, total inventory, net income, gross income, operating income, pretaxincome, cash flow operation, total liabilities, and total asset after ISO and ERP implementation. The resultsshowed that there was no significant difference of the ISO and ERP implementation on the factors of inventoryturnover, and weeks of supply. While the other factors showed significant differences between the implementationof ERP and ISO. Net profit margin, gross profit margin, and operating profit margin showed better resulton ERP launching. On the other hand, pretax margin showed better than ISO 9000 implementation. Overall,ERP implementation showed better results compared with ISO 9000.

  13. Beneficios de la aplicación de normas internacionales ISO en procesos electorales

    Directory of Open Access Journals (Sweden)

    Jeffrey Badí Quinteros Basantes

    2017-01-01

    Full Text Available En este artículo se presentarán los beneficios de la aplicabilidad de las normas internacionales ISO en los procesos electorales, con el fin de poder elevar los niveles de percepción positiva de los ciudadanos. Se verificará la aplicación de normas ISO/TS 17582:2014, Sistemas de Gestión de la Calidad y la norma ISO/IEC 27001:2013, para todas las fases de un proceso electoral. Se expondrán los dominios que forman parte de la norma ISO/TS 17582:2014 , los cuales permiten un proceso de mejoramiento continuo a fin de garantizar la calidad de las metodologías que soportan la organización, administración, gestión, seguimiento y auditorías de un proceso electoral. La norma ISO/IEC 27001:2013 se alinea con la norma ISO9001:2008 para la gestión de seguridad de la información. La aplicación de esta normativa permitirá asegurar la integridad, confidencialidad y disponibilidad de la información durante los procesos electorales.

  14. Framework for establishing records control in hospitals as an ISO 9001 requirement.

    Science.gov (United States)

    Al-Qatawneh, Lina

    2017-02-13

    Purpose The purpose of this paper is to present the process followed to control records in a Jordanian private community hospital as an ISO 9001:2008 standard requirement. Design/methodology/approach Under the hospital quality council's supervision, the quality management and development office staff were responsible for designing, planning and implementing the quality management system (QMS) using the ISO 9001:2008 standard. A policy for records control was established. An action plan for establishing the records control was developed and implemented. On completion, a coding system for records was specified to be used by hospital staff. Finally, an internal audit was performed to verify conformity to the ISO 9001:2008 standard requirements. Findings Successful certification by a neutral body ascertained that the hospital's QMS conformed to the ISO 9001:2008 requirements. A framework was developed that describes the records controlling process, which can be used by staff in any healthcare organization wanting to achieve ISO 9001:2008 accreditation. Originality/value Given the increased interest among healthcare organizations to achieve the ISO 9001 certification, the proposed framework for establishing records control is developed and is expected to be a valuable management tool to improve and sustain healthcare quality.

  15. The Role of ISO 9000 Certification on Waste Management of Leather Industry

    International Nuclear Information System (INIS)

    Susetyo Hario Putero; Dhani Astuti

    2008-01-01

    State of industry in an area could increase economy of this area. On the other hand, industry may be produce the waste. There are many factor influencing the success of industrial waste management. At present, ISO 14000 is known as an international environmental management standard. Practically, several matter required for ISO 14000 are similar with ISO 9000. So, the role of ISO 9000 certification on supporting waste management program of leather industry has been studied. Study has been pursued by comparing the environmental management systems of 2 leather industries in Sitimulyo, Piyungan, Bantul. Staff working way has been observed to know the suitability with working procedures and implementation of safety aspect on daily working. Observation of waste treatment facility and measurement of Chrome concentration also has been done. Samples were analysed using AAS method in Department of Chemistry, Faculty of Mathematics and Natural Science, Gadjah Mada University. Decontamination Factor (DF) was calculated by comparing the Chrome concentrations on outside plant and in waste treatment facility. Commitment of management and orderliness of system as required on ISO 9000 certification could push the industry to well execute waste management program as a part of environmental management system. ISO 9000 certification is convinced to make awareness of industry grow for continually improving their capability, including their capacity of waste treatment facility. (author)

  16. OntoCR: A CEN/ISO-13606 clinical repository based on ontologies.

    Science.gov (United States)

    Lozano-Rubí, Raimundo; Muñoz Carrero, Adolfo; Serrano Balazote, Pablo; Pastor, Xavier

    2016-04-01

    To design a new semantically interoperable clinical repository, based on ontologies, conforming to CEN/ISO 13606 standard. The approach followed is to extend OntoCRF, a framework for the development of clinical repositories based on ontologies. The meta-model of OntoCRF has been extended by incorporating an OWL model integrating CEN/ISO 13606, ISO 21090 and SNOMED CT structure. This approach has demonstrated a complete evaluation cycle involving the creation of the meta-model in OWL format, the creation of a simple test application, and the communication of standardized extracts to another organization. Using a CEN/ISO 13606 based system, an indefinite number of archetypes can be merged (and reused) to build new applications. Our approach, based on the use of ontologies, maintains data storage independent of content specification. With this approach, relational technology can be used for storage, maintaining extensibility capabilities. The present work demonstrates that it is possible to build a native CEN/ISO 13606 repository for the storage of clinical data. We have demonstrated semantic interoperability of clinical information using CEN/ISO 13606 extracts. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Molecular mechanisms behind the antimicrobial activity of hop iso-α-acids in Lactobacillus brevis.

    Science.gov (United States)

    Schurr, Benjamin C; Hahne, Hannes; Kuster, Bernhard; Behr, Jürgen; Vogel, Rudi F

    2015-04-01

    The main bittering component in beer, hop iso-α-acids, have been characterised as weak acids, which act as ionophores impairing microbial cells' function under acidic conditions as present in beer. Besides medium pH, divalent cations play a central role regarding the efficacy of the antimicrobial effect. The iso-α-acids' non-bitter derivatives humulinic acids can be found in isomerised hop extracts and can be generated during hop storage. Therefore, they have been under investigation concerning their influence on beer sensory properties. This study sketches the molecular mechanism behind iso-α-acids' antimicrobial activity in Lactobacillus (L.) brevis regarding their ionophore activity versus the dependence of the inhibitory potential on manganese binding, and suggests humulinic acids as novel tasteless food preservatives. We designed and synthesised chemically modified iso-α-acids to enhance the basic understanding of the molecular mechanism of antimicrobial iso-α-acids. It could be observed that a manganese-binding dependent transmembrane redox reaction (oxidative stress) plays a crucial role in inhibition. Privation of an acidic hydroxyl group neither erased ionophore activity, nor did it entirely abolish antimicrobial activity. Humulinic acids proved to be highly inhibitory, even outperforming iso-α-acids. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. PENGGABUNGAN PENERAPAN SISTEM JAMINAN MUTU ISO 9001:2008 DAN SISTEM HACCP KE DALAM SISTEM MANAJEMEN KEAMANAN PANGAN ISO 22000:2009 (STUDI KASUS DI PT INDOKOM SAMUDRA PERSADA [The Merger of Quality Assurance System ISO 9001:2008 and HACCP system into Food

    Directory of Open Access Journals (Sweden)

    Novri Ilmiawan

    2014-10-01

    Full Text Available The object of this research was to merge the application of HACCP system and ISO 9001:2008 in ISP company into ISO 22000:2009. The  research method used was case study method. The study was conducted on three stages. The first was the arrangement gap analysis conducted by comparing the conditions of the company with ISO 22000:2009 standards. The second was by observing sanitation and pre requisite programs. The third was by observing traceability system. The data in this research were reported descriptively, consisted of ISO 9001:2008 and HACCP application in the company and the gaps of principles in ISO 22000:2009 toward ISO 9001:2008 and HACCP. The result showed that ISP company has applied 12 steps which covered in HACCP system, and also the ISO 9001 system were appropriate with ISO 9001:2008 standards in every clauses. Pre requisite program (GMP and SSOP have been effectively applied. GMP in ISP company is categorized on the first spot (excellent. The eight keys of SSOP have been fulfilled. ISP company has been fulfilling 54 from 57 (94.74% criteria in ISO 22000:2009 standards, yet there still several things needed to be improved, which are the quality manual content  and HACCP table plan and its monitoring. The  traceability system has been applied well in ISP. Keywords : HACCP, ISO 9001, ISO 22000, GMP, SSOP.

  19. SISTEM HACCP KE DALAM SISTEM MANAJEMEN KEAMANAN PANGAN ISO 22000:2009 (STUDI KASUS DI PT INDOKOM SAMUDRA PERSADA [The Merger of Quality Assurance System ISO 9001:2008 and HACCP system into Food Safety Management SystemISO 22000:2009 (Case Study at Indoko

    Directory of Open Access Journals (Sweden)

    Novri Ilmiawan

    2014-12-01

    Full Text Available The object of this research was to merge the application of HACCP system and ISO 9001:2008 in ISP company into ISO 22000:2009. The  research method used was case study method. The study was conducted on three stages. The first was the arrangement gap analysis conducted by comparing the conditions of the company with ISO 22000:2009 standards. The second was by observing sanitation and pre requisite programs. The third was by observing traceability system. The data in this research were reported descriptively, consisted of ISO 9001:2008 and HACCP application in the company and the gaps of principles in ISO 22000:2009 toward ISO 9001:2008 and HACCP. The result showed that ISP company has applied 12 steps which covered in HACCP system, and also the ISO 9001 system were appropriate with ISO 9001:2008 standards in every clauses. Pre requisite program (GMP and SSOP have been effectively applied. GMP in ISP company is categorized on the first spot (excellent. The eight keys of SSOP have been fulfilled. ISP company has been fulfilling 54 from 57 (94.74% criteria in ISO 22000:2009 standards, yet there still several things needed to be improved, which are the quality manual content  and HACCP table plan and its monitoring. The  traceability system has been applied well in ISP .   Key words : HACCP, ISO 9001, ISO 22000, GMP, SSOP.

  20. Definition of a CDI metadata profile and its ISO 19139 based encoding

    Science.gov (United States)

    Boldrini, Enrico; de Korte, Arjen; Santoro, Mattia; Schaap, Dick M. A.; Nativi, Stefano; Manzella, Giuseppe

    2010-05-01

    The Common Data Index (CDI) is the middleware service adopted by SeaDataNet for discovery and query. The primary goal of the EU funded project SeaDataNet is to develop a system which provides transparent access to marine data sets and data products from 36 countries in and around Europe. The European context of SeaDataNet requires that the developed system complies with European Directive INSPIRE. In order to assure the required conformity a GI-cat based solution is proposed. GI-cat is a broker service able to mediate from different metadata sources and publish them through a consistent and unified interface. In this case GI-cat is used as a front end to the SeaDataNet portal publishing the original data, based on CDI v.1 XML schema, through an ISO 19139 application profile catalog interface (OGC CSW AP ISO). The choice of ISO 19139 is supported and driven by INSPIRE Implementing Rules, that have been used as a reference through the whole development process. A mapping from the CDI data model to the ISO 19139 was hence to be implemented in GI-cat and a first draft quickly developed, as both CDI v.1 and ISO 19139 happen to be XML implementations based on the same abstract data model (standard ISO 19115 - metadata about geographic information). This first draft mapping pointed out the CDI metadata model differences with respect to ISO 19115, as it was not possible to accommodate all the information contained in CDI v.1 into ISO 19139. Moreover some modifications were needed in order to reach INSPIRE compliance. The consequent work consisted in the definition of the CDI metadata model as a profile of ISO 19115. This included checking of all the metadata elements present in CDI and their cardinality. A comparison was made with respect to ISO 19115 and possible extensions were individuated. ISO 19139 was then chosen as a natural XML implementation of this new CDI metadata profile. The mapping and the profile definition processes were iteratively refined leading up to a

  1. Development and characterization of poli composites (ether ether ketone)(PEEK)(Hydroxyapatite(HA); Desenvolvimento e caracterizacao de compositos poli (eter-eter-cetona)(PEEK)/Hidroxiapatita(HA)

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, V.P.; Santos, F.S.F.; Sa, M.D. de; Fook, M.V.L., E-mail: valeriap.ferreira@hotmail.com [Universidade Federal de Campina Grande (UFCG), PB (Brazil). Centro de Ciencias e Tecnologia. Programa de Pos-Graduacao em Ciencia e Engenharia de Materiais

    2016-07-01

    The objective of this work was to develop PEEK / HA composites, combining the biological activity of the ceramic phase with the properties of the polymer phase, the materials used in this research were Poly (ether-ether-ketone) (PEEK) and Hydroxyapatite (HA) (50, 60, 70 and 80% m / v HA), this material was subjected to a load of two tons followed by a thermal treatment at 390 ° for a period of 30 minutes. Then they were characterized by FTIR, DRX and MO. In the physical-chemical characterization of FTIR and XRD, it was not possible to identify significant alterations. In the FTIR spectra of the composites, there is no formation of new identifiable chemical bonds. In the composites XRD diffractograms a profile similar to the ceramic phase was observed, with peaks increasing in intensity and narrowing proportional to the increase of the hydroxyapatite concentration in the composites. In optical microscopy it is possible to observe surfaces with heterogeneous morphology, with signs of roughness and in the cross section we observe a heterogeneous aspect, rich in regions with large agglomerates and lighter particles. Considering the processing aspects, the technique proved to be effective for the development of PEEK /HA composites. (author)

  2. Sr-containing hydroxyapatite: morphologies of HA crystals and bioactivity on osteoblast cells

    Energy Technology Data Exchange (ETDEWEB)

    Aina, Valentina [Department of Chemistry, Università degli Studi di Torino, Via P. Giuria 7, 10125 Torino (Italy); Centre of Excellence NIS (Nanostructured Interfaces and Surface) Università degli Studi di Torino (Italy); INSTM (Italian National Consortium for Materials Science and Technology), UdR Università di Torino (Italy); Bergandi, Loredana, E-mail: loredana.bergandi@unito.it [Department of Oncology, Università degli Studi di Torino, Via Santena 5/bis, 10126 Torino (Italy); Lusvardi, Gigliola; Malavasi, Gianluca [Department of Chemical and Geological Sciences, Università di Modena and Reggio Emilia, Via Campi 183, 41125 Modena (Italy); Imrie, Flora E.; Gibson, Iain R. [School of Medical Sciences, Institute of Medical Sciences, University of Aberdeen, Foresterhill, Aberdeen, AB25 2ZD (United Kingdom); Cerrato, Giuseppina [Department of Chemistry, Università degli Studi di Torino, Via P. Giuria 7, 10125 Torino (Italy); Centre of Excellence NIS (Nanostructured Interfaces and Surface) Università degli Studi di Torino (Italy); INSTM (Italian National Consortium for Materials Science and Technology), UdR Università di Torino (Italy); Ghigo, Dario [Department of Oncology, Università degli Studi di Torino, Via Santena 5/bis, 10126 Torino (Italy)

    2013-04-01

    A series of Sr-substituted hydroxyapatites (HA), of general formula Ca{sub (10−x)}Sr{sub x}(PO{sub 4}){sub 6}(OH){sub 2}, where x = 2 and 4, were synthesized by solid state methods and characterized extensively. The reactivity of these materials in cell culture medium was evaluated, and the behavior towards MG-63 osteoblast cells (in terms of cytotoxicity and proliferation assays) was studied. Future in vivo studies will give further insights into the behavior of the materials. A paper by Lagergren et al. (1975), concerning Sr-substituted HA prepared by a solid state method, reports that the presence of Sr in the apatite composition strongly influences the apatite diffraction patterns. Zeglinsky et al. (2012) investigated Sr-substituted HA by ab initio methods and Rietveld analyses and reported changes in the HA unit cell volume and shape due to the Sr addition. To further clarify the role played by the addition of Sr on the physico-chemical properties of these materials we prepared Sr-substituted HA compositions by a solid state method, using different reagents, thermal treatments and a multi-technique approach. Our results indicated that the introduction of Sr at the levels considered here does influence the structure of HA. There is also evidence of a decrease in the crystallinity degree of the materials upon Sr addition. The introduction of increasing amounts of Sr into the HA composition causes a decrease in the specific surface area and an enrichment of Sr-apatite phase at the surface of the samples. Bioactivity tests show that the presence of Sr causes changes in particle size and/or morphology during soaking in MEM solution; on the contrary the morphology of pure HA does not change after 14 days of reaction. The presence of Sr, as Sr-substituted HA and SrCl{sub 2,} in cultures of human MG-63 osteoblasts did not produce any cytotoxic effect. In fact, Sr-substituted HA increased the proliferation of osteoblast cells and enhanced cell differentiation: Sr in

  3. Sr-containing hydroxyapatite: morphologies of HA crystals and bioactivity on osteoblast cells

    International Nuclear Information System (INIS)

    Aina, Valentina; Bergandi, Loredana; Lusvardi, Gigliola; Malavasi, Gianluca; Imrie, Flora E.; Gibson, Iain R.; Cerrato, Giuseppina; Ghigo, Dario

    2013-01-01

    A series of Sr-substituted hydroxyapatites (HA), of general formula Ca (10−x) Sr x (PO 4 ) 6 (OH) 2 , where x = 2 and 4, were synthesized by solid state methods and characterized extensively. The reactivity of these materials in cell culture medium was evaluated, and the behavior towards MG-63 osteoblast cells (in terms of cytotoxicity and proliferation assays) was studied. Future in vivo studies will give further insights into the behavior of the materials. A paper by Lagergren et al. (1975), concerning Sr-substituted HA prepared by a solid state method, reports that the presence of Sr in the apatite composition strongly influences the apatite diffraction patterns. Zeglinsky et al. (2012) investigated Sr-substituted HA by ab initio methods and Rietveld analyses and reported changes in the HA unit cell volume and shape due to the Sr addition. To further clarify the role played by the addition of Sr on the physico-chemical properties of these materials we prepared Sr-substituted HA compositions by a solid state method, using different reagents, thermal treatments and a multi-technique approach. Our results indicated that the introduction of Sr at the levels considered here does influence the structure of HA. There is also evidence of a decrease in the crystallinity degree of the materials upon Sr addition. The introduction of increasing amounts of Sr into the HA composition causes a decrease in the specific surface area and an enrichment of Sr-apatite phase at the surface of the samples. Bioactivity tests show that the presence of Sr causes changes in particle size and/or morphology during soaking in MEM solution; on the contrary the morphology of pure HA does not change after 14 days of reaction. The presence of Sr, as Sr-substituted HA and SrCl 2, in cultures of human MG-63 osteoblasts did not produce any cytotoxic effect. In fact, Sr-substituted HA increased the proliferation of osteoblast cells and enhanced cell differentiation: Sr in HA has a positive effect

  4. Preparation, optimization and property of PVA-HA/PAA composite hydrogel.

    Science.gov (United States)

    Chen, Kai; Liu, Jinlong; Yang, Xuehui; Zhang, Dekun

    2017-09-01

    PVA-HA/PAA composite hydrogel is prepared by freezing-thawing, PEG dehydration and annealing method. Orthogonal design method is used to choose the optimization combination. Results showed that HA and PVA have the maximum effect on water content. PVA and freezing-thawing cycles have the maximum effect on creep resistance and stress relaxation rate of hydrogel. Annealing temperature and freezing-thawing cycles have the maximum effect on compressive elastic modulus of hydrogel. Comparing with the water content and mechanical properties of 16 kinds of combination, PVA-HA/PAA composite hydrogel with freezing-thawing cycles of 3, annealing temperature of 120°C, PVA of 16%, HA of 2%, PAA of 4% has the optimization comprehensive properties. PVA-HA/PAA composite hydrogel has a porous network structure. There are some interactions between PVA, HA and PAA in hydrogel and the properties of hydrogel are strengthened. The annealing treatment improves the crystalline and crosslinking of hydrogel. Therefore, the annealing PVA-HA/PAA composite hydrogel has good thermostability, strength and mechanical properties. It also has good lubrication property and its friction coefficient is relative low. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. 3D bioprinting of methacrylated hyaluronic acid (MeHA) hydrogel with intrinsic osteogenicity.

    Science.gov (United States)

    Poldervaart, Michelle T; Goversen, Birgit; de Ruijter, Mylene; Abbadessa, Anna; Melchels, Ferry P W; Öner, F Cumhur; Dhert, Wouter J A; Vermonden, Tina; Alblas, Jacqueline

    2017-01-01

    In bone regenerative medicine there is a need for suitable bone substitutes. Hydrogels have excellent biocompatible and biodegradable characteristics, but their visco-elastic properties limit their applicability, especially with respect to 3D bioprinting. In this study, we modified the naturally occurring extracellular matrix glycosaminoglycan hyaluronic acid (HA), in order to yield photo-crosslinkable hydrogels with increased mechanical stiffness and long-term stability, and with minimal decrease in cytocompatibility. Application of these tailor-made methacrylated hyaluronic acid (MeHA) gels for bone tissue engineering and 3D bioprinting was the subject of investigation. Visco-elastic properties of MeHA gels, measured by rheology and dynamic mechanical analysis, showed that irradiation of the hydrogels with UV light led to increased storage moduli and elastic moduli, indicating increasing gel rigidity. Subsequently, human bone marrow derived mesenchymal stromal cells (MSCs) were incorporated into MeHA hydrogels, and cell viability remained 64.4% after 21 days of culture. Osteogenic differentiation of MSCs occurred spontaneously in hydrogels with high concentrations of MeHA polymer, in absence of additional osteogenic stimuli. Addition of bone morphogenetic protein-2 (BMP-2) to the culture medium further increased osteogenic differentiation, as evidenced by increased matrix mineralisation. MeHA hydrogels demonstrated to be suitable for 3D bioprinting, and were printed into porous and anatomically shaped scaffolds. Taken together, photosensitive MeHA-based hydrogels fulfilled our criteria for cellular bioprinted bone constructs within a narrow window of concentration.

  6. Changes of serum HA and LN level in patients with pulmonary tuberculosis after therapy

    International Nuclear Information System (INIS)

    Yu Jing Zhang Hongwei; Li Jie

    2007-01-01

    Objective: To study the serum HA and LN level in patients with pulmonary tuberculosis and their response to therapy. Methods: Serum HA and LN levels were measured with RIA in: (1) 42 patients with active pulmonary tuberculosis both before and after 2 months' therapy, (2) 40 patients with non-active pulmonary TB and 330 controls. Results: The serum HA and LN level in patients with active pulmonary tubemulosis were significantly higher than those in controls (P < 0.01 ), while no significant difference could Be found Between the levels in patients with non-active pulmonary tuberculosis and controls. The serum HA and LN level in patients with active pulmonary tuberculosis dropped after therapy, but were still higher than those in controls. Significant correlation could Be found between HA and LN levels (P<0.01). The HA and LN levels were positively correlated with severity of the disease, ESR and CRP contents. Conclusion: The measurement of serum HA and LN is valuable for early diagnosis, monitoring development and assessment of therapeutic effect in patients with pulmonary tubemulosis. (authors)

  7. Human hypervariable sequences in risk assessment: rare Ha-ras alleles in cancer patients

    International Nuclear Information System (INIS)

    Krontiris, T.G.; DiMartino, N.A.; Mitcheson, H.D.; Lonergan, J.A.; Begg, C.; Parkinson, D.R.

    1987-01-01

    A variable tandem repeat (VTR) is responsible for the hyperallelism one kilobase 3' to the human c-Ha-ras-1 (Ha-ras) gene. Thirty-two distinct restriction fragments, comprising 3 allelic classes by frequency of occurrence, have thus far been detected in a sample size of approximately 800 caucasians. Rare Ha-ras alleles, 21 in all, are almost exclusively confined to the genomes of cancer patients. From their data the authors have computed the relative cancer risk associated with possession of a rare Ha-ras allele to be 27. To understand the molecular basis for this phenomenon, they have begun to clone Ha-ras fragments from nontumor DNA of cancer patients. They report here the weak activation, as detected by transfection and transformation of NIH 3T3 mouse cells, of two Ha-ras genes which were obtained from lymphocyte DNA of a melanoma patient. They have mapped the regions that confer this transforming activity to the fragment containing the VTR in one Ha-ras clone and the fragment containing gene coding sequences in the other

  8. 3D bioprinting of methacrylated hyaluronic acid (MeHA hydrogel with intrinsic osteogenicity.

    Directory of Open Access Journals (Sweden)

    Michelle T Poldervaart

    Full Text Available In bone regenerative medicine there is a need for suitable bone substitutes. Hydrogels have excellent biocompatible and biodegradable characteristics, but their visco-elastic properties limit their applicability, especially with respect to 3D bioprinting. In this study, we modified the naturally occurring extracellular matrix glycosaminoglycan hyaluronic acid (HA, in order to yield photo-crosslinkable hydrogels with increased mechanical stiffness and long-term stability, and with minimal decrease in cytocompatibility. Application of these tailor-made methacrylated hyaluronic acid (MeHA gels for bone tissue engineering and 3D bioprinting was the subject of investigation. Visco-elastic properties of MeHA gels, measured by rheology and dynamic mechanical analysis, showed that irradiation of the hydrogels with UV light led to increased storage moduli and elastic moduli, indicating increasing gel rigidity. Subsequently, human bone marrow derived mesenchymal stromal cells (MSCs were incorporated into MeHA hydrogels, and cell viability remained 64.4% after 21 days of culture. Osteogenic differentiation of MSCs occurred spontaneously in hydrogels with high concentrations of MeHA polymer, in absence of additional osteogenic stimuli. Addition of bone morphogenetic protein-2 (BMP-2 to the culture medium further increased osteogenic differentiation, as evidenced by increased matrix mineralisation. MeHA hydrogels demonstrated to be suitable for 3D bioprinting, and were printed into porous and anatomically shaped scaffolds. Taken together, photosensitive MeHA-based hydrogels fulfilled our criteria for cellular bioprinted bone constructs within a narrow window of concentration.

  9. Diagnóstico da integração dos sistemas de gestão ISO 9001, ISO 14001 e OHSAS 18001

    Directory of Open Access Journals (Sweden)

    Samuel Vinícius Bonato

    2015-09-01

    Full Text Available Este artigo apresenta os resultados de uma pesquisa que teve por finalidade o diagnóstico do nível de integração de sistemas de gestão baseados nas normas ISO 9001, ISO 14001 e OHSAS 18001 em empresas do ramo metal-mecânico. Inicialmente foi descrito o método de diagnóstico e posteriormente realizada a sua aplicação em uma empresa já certificada nas três normas, mas que possui dois sistemas de gestão distintos: o Sistema de Gestão da Qualidade (SGQ baseado na norma ISO 9001 e o Sistema de Gestão de Saúde, Segurança e Meio Ambiente (SSM baseado nas normas ISO 14001 e OHSAS 18001. Entre os principais resultados, destaca-se a aceitação favorável do diagnóstico da integração na empresa estudada. Com a realização do diagnóstico, verificou-se que a organização não atende totalmente a integração de nenhum dos requisitos avaliados. Foram sugeridas oportunidades de melhoria para integração dos requisitos normativos comuns, reduzindo custos e recursos para manutenção do sistema de gestão da empresa.

  10. Modelovanje georeferenciranih podataka u katastru nepokretnosti primenom ISO 19100 serije standarda / Spatial data modeling in the real estate cadastre using ISO 19100 series of standards

    Directory of Open Access Journals (Sweden)

    Mirko N. Petrović

    2010-01-01

    Full Text Available Potreba za standardizacijom u oblasti geografskih informacionih sistema odavno postoji. Međunarodne aktivnosti na ovom polju rezultirale su uspostavljanjem ISO 19100 serije standarda, kojima se regulišu različiti aspekti na polju geoinformatike. U članku su opisane mogućnosti primene relevantnih standarda iz serije ISO 19100 u modelovanju georeferenciranih podataka za katastar nepokretnosti. / Introduction Standardization in geo-information technologies contributes to the establishment of efficient information functions, their greater stability and easier transition. Application of international, national and internal standards in the process of developing software products in the field of geo-information technology creates conditions for the development of efficient, low cost, reliable and secure software products. Spatial data modeling basics for real estate cadastre In terms of modeling, the spatial information of real estate cadastre is based on the vector data model which is suitable for modeling objects with a smaller number of properties with emphasis on the position. The vector spatial data model consists of two components: spatial and descriptive. The basis of the spatial one is geometry that contains metric data usually given in coordinates of a reference system. Geometry and Topology uniquely determine the shape, size and position of the object model in space, i.e. they represent its spatial component. Merging the spatial component with the descriptive one results in a completely defined object from the real world. Elements of spatial data quality Spatial data quality can be reviewed through a set of the following elements: origin, positional accuracy, attribute accuracy, completeness, logical consistency, semantic accuracy and the time information. The elements of spatial data quality listed above are provided using ISO 19100 series of standards. Application of ISO19100 series of standards in spatial data modeling for real

  11. Some considerations on the trunk Simulator ISO: experience in manufacturing, use and maintenance; Algumas consideracoes sobre o simulador de tronco da ISO: experiencia em fabricacao, uso e manutencao

    Energy Technology Data Exchange (ETDEWEB)

    Martins, Marcelo M.; Mauricio, Claudia L.P., E-mail: marcelo@ird.gov.br, E-mail: claudia@ird.gov.br [Instituto de Radioprotecao e Dosimetria (lRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2013-07-01

    To standardize the operational quantity H{sub p}(10), ISO defined a water slab phantom. The conversion factors from air kerma to individual dose equivalent, H{sub p}(10), for photon radiation are tabulated in ISO 4037-3, and from neutron fluence 10 H{sub p}(10) in ISO 8529-3. This paper presents some considerations concerning the manufacture, use and maintenance of seven ISO water slab phantoms. The experience of the IRD in manufacturing (in its own Mechanical Workshop) and keeping these phantoms and the main advantages and problems encountered during more than 10 years of heavy use, especially for neutron dosimetry, are fully described. An important consideration regarding the interior of the phantom relates to internal cleanliness and quality of the water used to fill it. Another is about the positioning of multiple monitors on a single simulator, including irradiation angles, and the possibility of using multi pie phantoms for isotropic irradiation fields. Finally, it is presented the problems occurred in some phantoms, such as leaks and how to fix them. The two older phantoms, employed exclusively in neutron irradiation, have visible trails of damage in polymethylmethacrylate (PMMA), converging towards its centre, along its front wall, making it more fragile. This is caused by the interaction of radiation with the PMMA. (author)

  12. Fabrication and evaluation of porous Ti–HA bio-nanomaterial by leaching process

    Directory of Open Access Journals (Sweden)

    A.M. Omran

    2015-05-01

    Full Text Available A porous surface of Ti–HA composite was successfully fabricated by pulsed current activated sintering (PCAS, followed by leaching using diluted H3PO4. The Ti and HA powders were mixed at different contents of the HA, Ti-5, 10, 30 and 40 wt% HA powders. The mixed powders were pressed in a coated graphite die using pulsed current activated sintering (PCAS under pressure of 60 MPa at temperature of 1000 °C for 5 min. The sintered Ti–HA specimens were immersed in the eight kinds of leaching solutions at room temperature for 24 h. The leached specimen’s surfaces were characterized using XRD, SEM, EDX and Rockwell hardness. The XRD patterns after sintering show that many phases were detected at the sintered specimen surfaces such as; Ti2O, CaO, CaTiO3, TixPy in addition to the remaining Ti and HA. Furthermore, the high concentration H3PO4 leaching solution is more efficient than the low concentration. Also the produced porous surfaces of Ti–HA materials containing more than 30% HA have a low relative density and hardness than the commercial Ti–6Al–4V ELI alloy. In a word, the presence of porous surface coated by HA will promote the nucleation of the biological apatite created with the human tissue and increase the bonding between them. So, the produced porous materials are considered so easy for the muscle cells to permeate after transplanted with high coherence.

  13. HVOF-Sprayed Nano TiO2-HA Coatings Exhibiting Enhanced Biocompatibility

    Science.gov (United States)

    Lima, R. S.; Dimitrievska, S.; Bureau, M. N.; Marple, B. R.; Petit, A.; Mwale, F.; Antoniou, J.

    2010-01-01

    Biomedical thermal spray coatings produced via high-velocity oxy-fuel (HVOF) from nanostructured titania (n-TiO2) and 10 wt.% hydroxyapatite (HA) (n-TiO2-10wt.%HA) powders have been engineered as possible future alternatives to HA coatings deposited via air plasma spray (APS). This approach was chosen due to (i) the stability of TiO2 in the human body (i.e., no dissolution) and (ii) bond strength values on Ti-6Al-4V substrates more than two times higher than those of APS HA coatings. To explore the bioperformance of these novel materials and coatings, human mesenchymal stem cells (hMSCs) were cultured from 1 to 21 days on the surface of HVOF-sprayed n-TiO2 and n-TiO2-10 wt.%HA coatings. APS HA coatings and uncoated Ti-6Al-4V substrates were employed as controls. The profiles of the hMSCs were evaluated for (i) cellular proliferation, (ii) biochemical analysis of alkaline phosphatase (ALP) activity, (iii) cytoskeleton organization (fluorescent/confocal microscopy), and (iv) cell/substrate interaction via scanning electron microscopy (SEM). The biochemical analysis indicated that the hMSCs cultured on n-TiO2-10 wt.%HA coatings exhibited superior levels of bioactivity than hMSCs cultured on APS HA and pure n-TiO2 coatings. The cytoskeleton organization demonstrated a higher degree of cellular proliferation on the HVOF-sprayed n-TiO2-10wt.%HA coatings when compared to the control coatings. These results are considered promising for engineering improved performance in the next generation of thermally sprayed biomedical coatings.

  14. Lean-Agile Adaptations in Clinical Laboratory Accredited ISO 15189

    Directory of Open Access Journals (Sweden)

    Carlos Vilaplana Pérez

    2015-12-01

    Full Text Available It’s introduced Lean techniques in a Clinical Laboratory to improve the operability and the efficiency in continuous processes of analysis, failsafe systems, analysis of areas of value pursuit of zero defects and reduction of waste, and it promote continuous improvement in presented difficulties in adapting to the changing needs of the healthcare environment. Whereas it is necessary to incorporate certification and accreditation, note that the adaptability of the clinical laboratory to the changing needs of physicians in obtaining analytical information is reduced. The application of an agile methodology on analytical systems can provide a line of work that allows the incorporation of planning short work cycles on equips quickly with operational autonomy on the basis of demand and respecting the accreditation requirements and flexibility to ensure adequate performance as the intercomparison of results from the different units analytics, analytical quality and turnaround times. Between 2012 and 2014, a process of analysis and improvement was applied to circuits, a 5 s system, transportation of samples, inventory of reactive and samples, motion of personal and samples, reductions of waiting and delays, overproduction, over processing, and defects of results and reports. At last it seems necessary to apply the Agile methodology to adapt to the evolving necessities in time and the different origins of the samples. It’s have used modular systems where the modules of this study are programmed with immunoassay techniques and it has reduced the operative modules depending on the required activity, ensuring the goals of turnaround times, analytic quality, service, health care continuity, and keeping up with the ISO 15189 accreditation requirements. The results of applying the concept of Lean-Agile to a modular system allows us to reduce the associated costs to the seasonal variation of the health care demand and to adapt the system to the changes on

  15. Utilizzo della metodologia di progettazione secondo ISO 9001:2000 per il re-engineering dei ricoveri chirurgici in degenza breve

    Directory of Open Access Journals (Sweden)

    G. Tarassi

    2003-05-01

    Full Text Available

    Obiettivi: migliorare l’assistenza al paziente, riducendo
    il periodo della degenza nella fase immediatamente
    postoperatoria; ridurre l’inappropriatezza di ricoveri in particolare inseriti nella lista del decreto sui LEA; utilizzare con maggior efficienza i posti letto e le risorse infermieristiche; avviare la organizzazione dell’attività per processi all’interno del Sistema qualità ISO 9001:2000.


    Materiali e metodi: la riorganizzazione ha interessato
    tutte le 6 unità operative di area chirurgica (chirurgia generale, chirurgia plastica, urologia, oculistica, ortopedia, ginecologia i servizi di prenotazione ed accettazione ricoveri, l’ambulatorio degli accertamenti preoperatori per un’area polidisciplinare di degenza breve da lunedì a venerdì con patologie chirurgiche con degenza media tra 0 e 4 giorni. Definiti i membri del gruppo di progetto, è
    stato stilato un calendario comprensivo di 2 riesami, 2 verifiche ed 1 validazione, secondo la metodologia ISO. È stato inoltre realizzato uno studio preliminare effettuato in collaborazione con tre ospedali.

    Risultati: risparmio di giornate di degenza a parità di case-mix; risparmio risorse infermieristiche a parità di assistenza; effettuazione DRG chirurgici a rischio di inappropriatezza in Day Surgery o One Day Surgery; verifica di un buon livello di customer satisfation; articolazione di unica segreteria per l’intero processo da prenotazione, accertamenti preoperatori, ricovero, intervento, dimissione, controlli con unico riferimento per il paziente con buon gradimento complessivo; costruzione di percorsi diagnostico-terapeutici
    condivisi tra diverse.

    Conclusioni: il progetto ha permesso di utilizzare in modo più efficiente posti letto e di organizzare per processi l’attività assistenziale con soddisfazione dell’utenza esterna e

  16. Estándares de calidad en los ensayos clínicos: ISO 9001-Buena Práctica Clínica Quality standards in clinical tests. ISO 9001: Good Clinical Practice

    Directory of Open Access Journals (Sweden)

    Sandra Álvarez Guerra

    2005-12-01

    Full Text Available La calidad en los ensayos clínicos conducidos por los centros de investigación por contrato , constituye un factor de suma importancia. En la actualidad estas instituciones usan como estándar de calidad la Buena Práctica Clínica. Sin embargo, su combinación con la Norma ISO 9001:2000, estándar de calidad, internacionalmente utilizado, no se ha generalizado. Para demostrar la factibilidad que el uso conjunto de estas normas brindan a las organizaciones se decidió establecer reflexiones para demostrar cómo se complementan ambos estándares de calidad en la realización de ensayos clínicos. Para esto se revisó bibliografía actualizada en dichos temas. Se valoraron aspectos en común como: clientes, responsabilidad, tratamiento de datos generados, estadística, control de la calidad y documentos esenciales. Por medio de estos aspectos ambas normas tributan a la calidad del ensayo clínico, para una mejor protección al paciente, resultados confiables, satisfacción de los clientes, internos y externos, que garanticen la mejora continua, y establecer planes de contingencia y medidas preventivas. Se concluye que ambas normativas no están en contraposición y pueden ser utilizadas como vía capaz de garantizar excelencia en el servicio brindado.The quality of clinical tests conducted by the research centers on contract is a very important factor. Nowadays, these institutions use Good Clinical Practice as the quality standard. However, the combination of the latter with internationally used ISO 9001:2000 quality standard has not yet been generalized. In order to prove the feasibility that the joint use of these standards offers to organizations, it was decided to reflect on the way both quality standards complement each other in the performance of clinical tests. To this end, updated literature review was made. Common aspects such as clients, responsibility, treatment of data, statistics, quality control and essential documents were

  17. The neuroprotective effects of α-iso-cubebene on dopaminergic cell death: involvement of CREB/Nrf2 signaling.

    Science.gov (United States)

    Park, Sun Young; Son, Beung Gu; Park, Young Hoon; Kim, Cheol-Min; Park, Geuntae; Choi, Young-Whan

    2014-09-01

    As a part of ongoing studies to elucidate pharmacologically active components of Schisandra chinensis, we isolated and studied α-iso-cubebene. The neuroprotective mechanisms of α-iso-cubebene in human neuroblastoma SH-SY5Y cells were investigated. α-Iso-cubebene significantly inhibited cytotoxicity and apoptosis due to 6-hydroxydopamine (6-OHDA)-induced neurotoxicity in dopaminergic SH-SY5Y cells. Pretreatment of cells with α-iso-cubebene reduced intracellular accumulation of ROS and calcium in response to 6-OHDA. The neuroprotective effects of α-iso-cubebene were found to result from protecting the mitochondrial membrane potential. Notably, α-iso-cubebene inhibited the release of apoptosis-inducing factor from the mitochondria into the cytosol and nucleus after 6-OHDA treatment. α-Iso-cubebene also induced the activation of PKA/PKB/CREB/Nrf2 and suppressed 6-OHDA-induced neurotoxicity. α-Iso-cubebene was found to induce phosphorylation of PKA and PKB and activate Nrf2 and CREB signaling pathways in a dose-dependent manner. Additionally, α-iso-cubebene stimulated the expression of the antioxidant response genes NQO1 and HO-1. Finally, α-iso-cubebene-mediated neuroprotective effects were found to be reversible after transfection with CREB and Nrf2 small interfering RNAs.

  18. WHAT IS THE PURPOSE OF ISO 9000 CERTIFICATION? EMPIRICAL EVIDENCE FROM FRENCH MICRO-DATA

    Directory of Open Access Journals (Sweden)

    Sanja Pekovic

    2008-03-01

    Full Text Available The ISO 9000 certification is often associated with quality approach, and activities that are by now widely diffused throughout business. The statistical research shows that quality management practice is one of the most utilized tools because in 1997, more than a third of industrial firms have received the quality certification. Regarded like an investment in a diploma, investment in quality norms can at the same time be a function of improvement of the company's competence and can also make a signal on the market. In our research, we want to understand those two functions of the ISO 9000 certification and to see how they act in the company and on the market. The paper will explore two possible functions of the certification and will analysis the consequences for the firms. The research will use national statistics sources and case research for the empirical investigation to identify the internal characteristics of ISO 9000 adoption. Also, it will use C.O.I database (Organizational Changes and Computerization of 1997 and E.A.E. database (Annual Survey of Industry. In this research, the empirical results show that ISO certification has a part of increase the level of firm's export. Moreover, the firms that have recently adopted the ISO certification invest more in quality than those that have adopted ISO certification more ago. The results show that the firms from same sector of activity "are pushed" to adopt certification. At the end, the results show that, the probability that the firm adopt ISO certification increase with firm's size.

  19. Analysis of the Environmental Management System based on ISO 14001 on the American continent.

    Science.gov (United States)

    Neves, Fábio de Oliveira; Salgado, Eduardo G; Beijo, Luiz A

    2017-09-01

    The American continent is in broad economic and industrial development. Consequently, a more detailed discussion of the impacts generated by such development is needed. Moreover, there is an increase in the number of ISO 14001 certificates issued to this continent. Given the above, no studies were found that bridge the gap to identify the influence of different factors on ISO 14001 in the Americas. Thus, this article has as its main aim to check which economic, environmental and cultural factors have influence on ISO 14001 Certification in the American Continent. The data were collected in the ISO Survey, World Bank, United Nations Development Programme and International Energy Agency. Among the countries of that continent, thirteen were analyzed and only two did not show the economic factors as the influence factor in the multiple regression models fitted with Brazil and the United State. In these models, all presented environmental factors as influencing factors. Only in Brazil the index HDI presented as cultural factor in multiple regression model fitted. The economic factors: Gross Domestic Product and exports of goods and services and environmental: Carbon Dioxide (CO 2 ) and fossil fuel consumption were the most influential in ISO 14001 certification. Venezuela, Uruguay, Colombia and the United States were countries that had factors dependent on each other, featuring the environmental marketing. Briefly, this study brings up several implications: to the academy, with the proposal of new concepts and guidance on the factors that assist in ISO 14001 certification in the American Continent. Additionally, taking into account the industry, the factors serve as efficiency parameters for the implementation of ISO 14001 standard, and for the Government to improve through factors that do not fit in multiple regression models. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Estimating ecosystem iso/anisohydry using microwave satellite data and its applications in ecohydrology

    Science.gov (United States)

    Li, Y.; Guan, K.; Gentine, P.; Konings, A. G.; Bhattacharya, A.; Meinzer, F. C.; Kimball, J. S.; Xu, X.; Anderegg, W.; McDowell, N. G.; Martínez-Vilalta, J.; Long, D. G.; Good, S. P.

    2017-12-01

    The concept of iso/anisohydry describes the degree to which plants regulate their water status, operating from isohydric with strict stomatal closure to anisohydric with greater stomatal conductance under drying conditions. Though some species-level measures of iso/anisohydry exist at limited locations, ecosystem scale information is still largely unavailable. In this study, we use diurnal observations from active (Ku-Band backscatter from QuikSCAT) and passive (X-band Vegetation Optical Depth [VOD] from AMSR-E) microwave satellite data to estimate global ecosystem iso/anisohydry. The two independent estimates from radar backscatter and VOD show good agreement at low and mid-latitudes but diverge at high latitudes. Grasslands, croplands, wetlands, and open shrublands are more anisohydric, whereas evergreen broadleaf and deciduous broadleaf forests are more isohydric. The direct validation with upscaled in-situ species iso/anisohydry estimates indicates that the VOD estimates have much better agreement than the backscatter in terms of their iso/anisohydry metrics. The indirect validation suggests that both estimates are consistent with prior knowledge that vegetation water status of anisohydric ecosystems more closely tracks environmental fluctuations of water availability and demand than their isohydric counterparts. The ecosystem level iso/anisohydry can be applied to reveal new insights into spatio-temporal ecosystem response to droughts. We conducted a case study to demonstrate the potential application of iso/anisohydry. We find that during the 2011 drought in US, over the drought affected region in the southern US, isohydric ecosystems experienced larger decline in productivity (NDVI and GPP) than anisohydric ones. However, during the 2012 drought in central US, both isohydric and anisohydric ecosystems exhibited similar decline in productivity.

  1. Pressure-dependent kinetics of initial reactions in iso-octane pyrolysis.

    Science.gov (United States)

    Ning, HongBo; Gong, ChunMing; Li, ZeRong; Li, XiangYuan

    2015-05-07

    This study focuses on the studies of the main pressure-dependent reaction types of iso-octane (iso-C8H18) pyrolysis, including initial C-C bond fission of iso-octane, isomerization, and β-scission reactions of the alkyl radicals produced by the C-C bond fission of iso-octane. For the C-C bond fission of iso-octane, the minimum energy potentials are calculated at the CASPT2(2e,2o)/6-31+G(d,p)//CAS(2e,2o)/6-31+G(d,p) level of theory. For the isomerization and the β-scission reactions of the alkyl radicals, the optimization of the geometries and the vibrational frequencies of the reactants, transition states, and products are performed at the B3LYP/CBSB7 level, and their single point energies are calculated by using the composite CBS-QB3 method. Variable reaction coordinate transition state theory (VRC-TST) is used for the high-pressure limit rate constant calculation and Rice-Ramsperger-Kassel-Marcus/master equation (RRKM/ME) is used to calculate the pressure-dependent rate constants of these channels with pressure varying from 0.01-100 atm. The rate constants obtained in this work are in good agreement with those available from literatures. We have updated the rate constants and thermodynamic parameters for species involved in these reactions into a current chemical kinetic mechanism and also have improved the concentration profiles of main products such as C3H6 and C4H6 in the shock tube pyrolysis of iso-octane. The results of this study provide insight into the pyrolysis of iso-octane and will be helpful in the future development of branched paraffin kinetic mechanisms.

  2. α-Iso-cubebene exerts neuroprotective effects in amyloid beta stimulated microglia activation.

    Science.gov (United States)

    Park, Sun Young; Park, Se Jin; Park, Nan Jeong; Joo, Woo Hong; Lee, Sang-Joon; Choi, Young-Whan

    2013-10-25

    Schisandra chinensis is commonly used for food and as a traditional remedy for the treatment of neuronal disorders. However, it is unclear which component of S. chinensis is responsible for its neuropharmacological effects. To answer this question, we isolated α-iso-cubebene, a dibenzocyclooctadiene lignin, from S. chinensis and determined if it has any anti-neuroinflammatory and neuroprotective properties against amyloid β-induced neuroinflammation in microglia. Microglia that are stimulated by amyloid β increased their production of pro-inflammatory cytokines and chemokines, prostaglandin E2 (PGE2), nitric oxide (NO) and reactive oxygen species (ROS) and the enzymatic activity of matrix metalloproteinase 9 (MMP-9). We found this was all inhibited by α-iso-cubebene. Consistent with these results, α-iso-cubebene inhibited the expression of inducible nitric oxide synthase (iNOS), cyclooxygenase 2 (COX-2) and MMP-9 in amyloid β-stimulated microglia. Subsequent mechanistic studies revealed that α-iso-cubebene inhibited the phosphorylation and degradation of IκB-α, the phosphorylation and transactivity of NF-κB, and the phosphorylation of MAPK in amyloid β-stimulated microglia. These results suggest that α-iso-cubebene impairs the amyloid β-induced neuroinflammatory response of microglia by inhibiting the NF-κB and MAPK signaling pathways. Importantly, α-iso-cubebene can provide critical neuroprotection for primary cortical neurons against amyloid β-stimulated microglia-mediated neurotoxicity. To the best of our knowledge, this is the first report showing that α-iso-cubebene can provide neuroprotection against, and influence neuroinflammation triggered by, amyloid β activation of microglia. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  3. The Effect of ISO 9001 and the EFQM Model on Improving Hospital Performance: A Systematic Review.

    Science.gov (United States)

    Yousefinezhadi, Taraneh; Mohamadi, Efat; Safari Palangi, Hossein; Akbari Sari, Ali

    2015-12-01

    This study aimed to explore the effect of the International Organization for Standardization (ISO) ISO 9001 standard and the European foundation for quality management (EFQM) model on improving hospital performance. PubMed, Embase and the Cochrane Library databases were searched. In addition, Elsevier and Springer were searched as main publishers in the field of health sciences. We included empirical studies with any design that had used ISO 9001 or the EFQM model to improve the quality of healthcare. Data were collected and tabulated into a data extraction sheet that was specifically designed for this study. The collected data included authors' names, country, year of publication, intervention, improvement aims, setting, length of program, study design, and outcomes. Seven out of the 121 studies that were retrieved met the inclusion criteria. Three studies assessed the EFQM model and four studies assessed the ISO 9001 standard. Use of the EFQM model increased the degree of patient satisfaction and the number of hospital admissions and reduced the average length of stay, the delay on the surgical waiting list, and the number of emergency re-admissions. ISO 9001 also increased the degree of patient satisfaction and patient safety, increased cost-effectiveness, improved the hospital admissions process, and reduced the percentage of unscheduled returns to the hospital. Generally, there is a lack of robust and high quality empirical evidence regarding the effects of ISO 9001 and the EFQM model on the quality care provided by and the performance of hospitals. However, the limited evidence shows that ISO 9001 and the EFQM model might improve hospital performance.

  4. Belgia rahvuspüha puhul kuuleb Eestis kammermuusikat / Maarja Pehk

    Index Scriptorium Estoniae

    Pehk, Maarja

    2007-01-01

    21. juulil on Belgia Kuningriigil rahvuspüha. Suursaadik Pierre Clement Dubuisson tutvustab sel puhul belgia kultuuri kolme kontserdi kaudu. Sel aastal tutvustab saatkond Belgia kultuuri ka koostöös Pimedate Ööde filmifestivaliga

  5. Hi ha un paper per a l'ètica a l'empresa?

    OpenAIRE

    Argandoña Rámiz, Antonio

    2001-01-01

    No hi ha decisions ètiques i decisions no ètiques. Hi ha decisions: l'ètica és, simplement, un component més de cada decisió —i, per tant, molt important. No hi ha directors d'empresa ètics i altres que no ho són: hi ha directors que dirigeixen bé, i directors que dirigeixen malament. Els que dirigeixen bé són ètics. Si no són ètics, estan perdent algun aspecte de la realitat que és necessari per a la seva tasca de dirigir: per tant, dirigeixen malament. Però, a més a més, ser ètic no és tan ...

  6. Metallpitsid Tallinna Püha Johannese hospidali (Jaani seegi) kalmistu haualeidudes / Sari Marjut Rainne

    Index Scriptorium Estoniae

    Rainne, Sari Marjut

    2010-01-01

    Tallinna Püha Johannese hospidali (Jaani seegi) kalmistualal toimunud arheoloogilistelt kaevamistelt leitud metallpitsidest. Ülevaade põhiliselt 18. sajandist pärit peakatete külge kinnitatud pitside materjaliuuringu tulemustest ja konserveerimisest

  7. Microstructure, mechanical properties, and biological response to functionally graded HA coatings

    International Nuclear Information System (INIS)

    Rabiei, Afsaneh; Blalock, Travis; Thomas, Brent; Cuomo, Jerry; Yang, Y.; Ong, Joo

    2007-01-01

    Hydroxyapatite (HA) [Ca 10 (PO 4 ) 6 (OH) 2 ] is the primary mineral content, representing 43% by weight, of bone. Applying a thin layer of HA, to the surface of a metal implant, can promote osseointegration and increase the mechanical stability of the implant. In this study, a biocompatible coating comprising an HA film with functionally graded crystallinity is being deposited on a heated substrate in an Ion Beam Assisted Deposition (IBAD) system. The microstructure of the film was studied using Transmission Electron Microscopy techniques. Finally, initial cell adhesion and cell differentiation on the coating was evaluated using ATCC CRL 1486 human embryonic palatal mesenchymal cell, an osteoblast precursor cell line. The results have shown superior mechanical properties and biological response to the functionally graded HA film

  8. 24 CFR 964.18 - HA role in activities under subparts B & C.

    Science.gov (United States)

    2010-04-01

    ... encourage the formation of joint HA management-resident committees to work on issues and planning. (9) The... elements of their partnership agreement and it shall be updated at least once every three (3) years. (11...

  9. Excellence in clinical laboratories: the standard ISO 15189:2007

    Directory of Open Access Journals (Sweden)

    Antonio Scipioni

    2010-06-01

    Full Text Available I laboratori clinici operano in stretto contatto con i pazienti e collaborano direttamente alla loro cura, in modo corresponsabile con i medici e i reparti ospedalieri. L’importanza della loro attività per la salute pubblica rende obbligatoria l’esplicitazione di alcuni punti finora spesso considerati ovvii. Ai pazienti dev’essere infatti garantito che: - i metodi di analisi utilizzati siano stati preliminarmente valutati, per confermare la loro rispondenza agli obiettivi dell’analisi stessa, verificati, per controllarne l’effettiva efficacia e, se necessario, validati per garantire che siano appropriati allo scopo; - il personale che esegue le analisi sia stato adeguatamente formato e quindi tecnicamente competente; - il laboratorio assicuri un’adeguata consulenza allo staff clinico che richiede le analisi, allo scopo di ottenere una sinergia tra il laboratorio e il clinico che ha in cura il paziente, sia nella fase di prelievo di materiale biologico, sia nella fase di interpretazione dei risultati. Tutto ciò è necessario per dimostrare ai pazienti

  10. New therapeutic agent for radiation synovectomy - preparation of {sup 166}Ho-EDTMP-HA particle

    Energy Technology Data Exchange (ETDEWEB)

    Bai, H.; Jin, X.; Du, J.; Wang, F.; Chen, D.; Fan, H.; Cheng, Z.; Zhang, J. [China Institute of Atomic Energy, Beijing (Switzerland). Isotope Department

    1997-10-01

    In order to prepare new therapeutical agent for radiation synovectomy, Hydroxyapatite (HA) was labelled with {sup 166}Ho by EDTMP that had high affinity to HA particles. Radiolabelling of HA particles was divided into two steps, {sup 166}Ho-EDTMP was prepared first; then mixed with HA particles completely and vibrated for 15 minutes on the micromixer at room temperature, washed 3 times with deionized water. Radiolabelling particle was separated from free {sup 166}Ho via centrifugation to determine its radiolabelling efficiency. {sup 166}Ho-EDTMP-HA and {sup 166}Ho-EDTMP were injected into knee joint of normal rabbits respectively, every group was killed at different time postinjection, took out major organ and collected urine and blood, then weighted and determined their radio counts. HA particles, as a natural component of bone was known to have good compatibility with soft tissue and biodegrade into calcium and phosphate in vivo. It was readily prepared from common chemical and formed into particles of desired size range in a controlled process, it had high stability in vitro and vivo. Radiolabelling of HA particle with {sup 166}Ho by EDTMP was simple to perform and provides an excellent labelling yield that was more than 95% under the optimal labelling condition. The optimal labelling condition at room temperature was pH 6.0-8.0 and vibration time 15 minutes. The absorbed capacity of HA particle was 5 mg Ho/g HA particle and size of radiolabelling particle was at range of 2-5,{mu}m that is suitable for therapy of radiation synovectomy. {sup 166}Ho-EDTMP-HA particle demonstrated high in vitro stability in either normal saline or 1% BSA solution, but instability under extremely acidic condition (pH 1-2). The control studies performed with {sup 166}Ho-EDTMP not bound to HA particle provided information on the distribution of radioactivity that would occur upon leakage of the radiochemical compound from joint. Its short half-life, its extremely low leakage from the

  11. Sequence diversity within the HA-1 gene as detected by melting temperature assay without oligonucleotide probes

    Directory of Open Access Journals (Sweden)

    Mattiuz Pier

    2005-10-01

    Full Text Available Abstract Background The minor histocompatibility antigens (mHags are self-peptides derived from common cellular proteins and presented by MHC class I and II molecules. Disparities in mHags are a potential risk for the development of graft-versus-host disease (GvHD in the recipients of bone marrow from HLA-identical donors. Two alleles have been identified in the mHag HA-1. The correlation between mismatches of the mHag HA-1 and GvHD has been suggested and methods to facilitate large-scale testing were afterwards developed. Methods We used sequence specific primer (SSP PCR and direct sequencing to detect HA-1 gene polymorphisms in a sample of 131 unrelated Italian subjects. We then set up a novel melting temperature (Tm assay that may help identification of HA-1 alleles without oligonucleotide probes. Results We report the frequencies of HA-1 alleles in the Italian population and the presence of an intronic 5 base-pair deletion associated with the immunogeneic allele HA-1H. We also detected novel variable sites with respect to the consensus sequence of HA-1 locus. Even though recombination/gene conversion events are documented, there is considerable linkage disequilibrium in the data. The gametic associations between HA-1R/H alleles and the intronic 5-bp ins/del polymorphism prompted us to try the Tm analysis with SYBR® Green I. We show that the addition of dimethylsulfoxide (DMSO during the assay yields distinct patterns when amplicons from HA-1H homozygotes, HA-1R homozygotes, and heterozygotes are analysed. Conclusion The possibility to use SYBR® Green I to detect Tm differences between allelic variants is attractive but requires great caution. We succeeded in allele discrimination of the HA-1 locus using a relatively short (101 bp amplicon, only in the presence of DMSO. We believe that, at least in certain assets, Tm assays may benefit by the addition of DMSO or other agents affecting DNA strand conformation and stability.

  12. New therapeutic agent for radiation synovectomy - preparation of 166Ho-EDTMP-HA particle

    International Nuclear Information System (INIS)

    Bai, H.; Jin, X.; Du, J.; Wang, F.; Chen, D.; Fan, H.; Cheng, Z.; Zhang, J.

    1997-01-01

    In order to prepare new therapeutical agent for radiation synovectomy, Hydroxyapatite (HA) was labelled with 166 Ho by EDTMP that had high affinity to HA particles. Radiolabelling of HA particles was divided into two steps, 166 Ho-EDTMP was prepared first; then mixed with HA particles completely and vibrated for 15 minutes on the micromixer at room temperature, washed 3 times with deionized water. Radiolabelling particle was separated from free 166 Ho via centrifugation to determine its radiolabelling efficiency. 166 Ho-EDTMP-HA and 166 Ho-EDTMP were injected into knee joint of normal rabbits respectively, every group was killed at different time postinjection, took out major organ and collected urine and blood, then weighted and determined their radio counts. HA particles, as a natural component of bone was known to have good compatibility with soft tissue and biodegrade into calcium and phosphate in vivo. It was readily prepared from common chemical and formed into particles of desired size range in a controlled process, it had high stability in vitro and vivo. Radiolabelling of HA particle with 166 Ho by EDTMP was simple to perform and provides an excellent labelling yield that was more than 95% under the optimal labelling condition. The optimal labelling condition at room temperature was pH 6.0-8.0 and vibration time 15 minutes. The absorbed capacity of HA particle was 5 mg Ho/g HA particle and size of radiolabelling particle was at range of 2-5,μm that is suitable for therapy of radiation synovectomy. 166 Ho-EDTMP-HA particle demonstrated high in vitro stability in either normal saline or 1% BSA solution, but instability under extremely acidic condition (pH 1-2). The control studies performed with 166 Ho-EDTMP not bound to HA particle provided information on the distribution of radioactivity that would occur upon leakage of the radiochemical compound from joint. Its short half-life, its extremely low leakage from the joint and its even distribution throughout

  13. Evaluation of nanohydroxyapaptite (nano-HA) coated epigallocatechin-3-gallate (EGCG) cross-linked collagen membranes.

    Science.gov (United States)

    Chu, Chenyu; Deng, Jia; Man, Yi; Qu, Yili

    2017-09-01

    Collagen is the main component of extracellular matrix (ECM) with desirable biological activities and low antigenicity. Collagen materials have been widely utilized in guided bone regeneration (GBR) surgery due to its abilities to maintain space for hard tissue growth. However, pure collagen lacks optimal mechanical properties. In our previous study, epigallocatechin-3-gallate (EGCG) cross-linked collagen membranes, with better biological activities and enhanced mechanical properties, may promote osteoblast proliferation, but their effect on osteoblast differentiation is not very significant. Nanohydroxyapatite (nano-HA) is the main component of mineral bone, which possesses exceptional bioactivity properties including good biocompatibility, high osteoconductivity and osteoinductivity, non-immunogenicity and non-inflammatory behavior. Herein, by analyzing the physical and chemical properties as well as the effects on promoting bone regeneration, we have attempted to present a novel EGCG-modified collagen membrane with nano-HA coating, and have found evidence that the novel collagen membrane may promote bone regeneration with a better surface morphology, without destroying collagen backbone. To evaluate the surface morphologies, chemical and mechanical properties of pure collagen membranes, epigallocatechin-3-gallate (EGCG) cross-linked collagen membranes, nano-HA coated collagen membranes, nano-HA coated EGCG-collagen membranes, (ii) to evaluate the bone regeneration promoted by theses membranes. In the present study, collagen membranes were divided into 4 groups: (1) untreated collagen membranes (2) EGCG cross-linked collagen membranes (3) nano-HA modified collagen membranes (4) nano-HA modified EGCG-collagen membranes. Scanning electron microscope (SEM) and Fourier transform infrared spectroscopy (FTIR) were used to evaluate surface morphologies and chemical properties, respectively. Mechanical properties were determined by differential scanning calorimeter (DSC

  14. 3D-printed scaffolds based on PLA/HA nanocomposites for trabecular bone reconstruction

    International Nuclear Information System (INIS)

    Niaza, K V; Senatov, F S; Kaloshkin, S D; Maksimkin, A V; Chukov, D I

    2016-01-01

    In the present work porous PLA scaffolds filled with micro- and nano- HA were studied. Both composites with micro- and nano-HA were obtained by extrusion in the same conditions. Scaffolds were obtained by 3D-printing by fused filament fabrication method. Structure of porous scaffolds was pre-modeled by computer software. Compression and three - point flexural tests were used to study mechanical properties of the scaffolds. (paper)

  15. HA Cells monitoring at the Underground Research Laboratory (URL) in the CMHM (Andra)

    International Nuclear Information System (INIS)

    Gay, Olivier; Allagnat, Dominique; Morel, Jacques; Armand, Gilles

    2010-01-01

    The experimental monitoring program of the HA (High Activity) cells was carried out at the Underground Research Laboratory (URL) in the Meuse Haute Marne department in France (CMHM Andra). Inspections made by video and photographs, section measurements and geo-referenced trajectories, in addition to measurements of convergence, temperature and hygrometry over time, allowed a better analysis of the behaviour of the HA cells after excavation, and subsequently over the long term. (authors)

  16. 3D-printed scaffolds based on PLA/HA nanocomposites for trabecular bone reconstruction

    Science.gov (United States)

    Niaza, K. V.; Senatov, F. S.; Kaloshkin, S. D.; Maksimkin, A. V.; Chukov, D. I.

    2016-08-01

    In the present work porous PLA scaffolds filled with micro- and nano- HA were studied. Both composites with micro- and nano-HA were obtained by extrusion in the same conditions. Scaffolds were obtained by 3D-printing by fused filament fabrication method. Structure of porous scaffolds was pre-modeled by computer software. Compression and three - point flexural tests were used to study mechanical properties of the scaffolds.

  17. Designing, preparing and evaluation of novel HA/Ti composite coating for endodontic dental implant

    Directory of Open Access Journals (Sweden)

    Fathi MH.

    2002-08-01

    Full Text Available Nowadays, application of implants as a new method for replacing extracted teeth have been improved. So, many researches have been performed for improving the characteristics of implants. The aim of this study was to design and produce a desired coating in order to obtaining two goals including; improvement of the corrosion behavior of metallic endodontic implant and the bone osseointegration simultaneously. Stainless steel 316L (SS, cobalt-chromium alloy (Vit and commercial pure titanium (cpTi were chosen as metallic substrates and hydroxyapatite coating (HAC were performed by plasma-spraying (PS process on three different substrates. A novel double layer Hydroxyapatite/Titanium (HA/Ti composite coating composed of a HA top layer and a Ti under layer was prepared using PS and physical vapor deposition (PVD process respectively on SS. Structural characterization techniques including XRD, SEM and EDX were utilized to investigate the microstructure, morpholgy and crystallinity of the coatings. Electrochemical potentiodynamic tests were performed in physiological solutions in order to determine and compare the corrosion behavior of the coated and uncoated specimens behavior as an indication of biocmpatibility. Results indicated that the cpTi possesses the highest and SS the lowest corrosion resistance (highest corrosion current density between uncoated substrates. This trend was independent to the type of physiological environment. The HA coating decreased the corrosion current density of HA coated metallic implants but did not change that trend. HAC acted as a mechanical barrier on the metallic substrate but could not prevent the interaction between metallic substrate and environment completely. The HA/Ti composite coating improved the corrosion behavior of SS. The corrosion current density of HA/Ti coated SS decreased and was exactly similar to single HA coated cpTi in physiological solutions. The results indicated that HA/Ti composite coated SS

  18. Does PEEK/HA Enhance Bone Formation Compared With PEEK in a Sheep Cervical Fusion Model?

    Science.gov (United States)

    Walsh, William R; Pelletier, Matthew H; Bertollo, Nicky; Christou, Chris; Tan, Chris

    2016-11-01

    Polyetheretherketone (PEEK) has a wide range of clinical applications but does not directly bond to bone. Bulk incorporation of osteoconductive materials including hydroxyapatite (HA) into the PEEK matrix is a potential solution to address the formation of a fibrous tissue layer between PEEK and bone and has not been tested. Using in vivo ovine animal models, we asked: (1) Does PEEK-HA improve cortical and cancellous bone ongrowth compared with PEEK? (2) Does PEEK-HA improve bone ongrowth and fusion outcome in a more challenging functional ovine cervical fusion model? The in vivo responses of PEEK-HA Enhanced and PEEK-OPTIMA ® Natural were evaluated for bone ongrowth in the form of dowels implanted in the cancellous and cortical bone of adult sheep and examined at 4 and 12 weeks as well as interbody cervical fusion at 6, 12, and 26 weeks. The bone-implant interface was evaluated with radiographic and histologic endpoints for a qualitative assessment of direct bone contact of an intervening fibrous tissue later. Gamma-irradiated cortical allograft cages were evaluated as well. Incorporating HA into the PEEK matrix resulted in more direct bone apposition as opposed to the fibrous tissue interface with PEEK alone in the bone ongrowth as well as interbody cervical fusions. No adverse reactions were found at the implant-bone interface for either material. Radiography and histology revealed resorption and fracture of the allograft devices in vivo. Incorporating HA into PEEK provides a more favorable environment than PEEK alone for bone ongrowth. Cervical fusion was improved with PEEK-HA compared with PEEK alone as well as allograft bone interbody devices. Improving the bone-implant interface with a PEEK device by incorporating HA may improve interbody fusion results and requires further clinical studies.

  19. A Study of Hybrid Composite Hydroxyapatite (HA-Geopolymers as a Material for Biomedical Application

    Directory of Open Access Journals (Sweden)

    Saleha

    2017-01-01

    Full Text Available The main purpose of this research is to study the physical properties and microstructure characters of hybrid composites HA-geopolymers as a material for biomedical application. Hybrid composite HA–geopolymers were produced through alkaline activation method of metakaolin as a matrix and HA as the filler. HA was synthesized from eggshell particles by using a precipitation method. The addition of HA in metakaolin paste was varied from 0.5%, 1.0%, 1.5%, and 2.0% relative the weight of metakaolin. FTIR was used to examine the absorption bands the composites. X-ray diffraction (XRD was used to study the crystal structure of the starting and the resulting materials. Scanning Electron Microscopy-Energy Dispersive Spectroscopy (SEM-EDS was used to investigate the surface morphology of the composites. The thermal properties of the samples was examined by means of Differential Scanning Calorimetry (DSC. Capacitance measurement was conducted to investigate the bioactive properties of HA. The study results suggest that hybrid composite HA-geopolymers has a potential to be applied as a biomedical such as biosensor material.

  20. Coordination of Retail Demand Response with Midwest ISO Markets

    Energy Technology Data Exchange (ETDEWEB)

    Bharvirkar, Ranjit; Bharvirkar, Ranjit; Goldman, Charles; Heffner, Grayson; Sedano, Richard

    2008-05-27

    The Organization of Midwest ISO States (OMS) launched the Midwest Demand Resource Initiative (MWDRI) in 2007 to identify barriers to deploying demand response (DR) resources in the Midwest Independent System Operator (MISO) region and develop policies to overcome them. The MWDRI stakeholders decided that a useful initial activity would be to develop more detailed information on existing retail DR programs and dynamic pricing tariffs, program rules, and utility operating practices. This additional detail could then be used to assess any"seams issues" affecting coordination and integration of retail DR resources with MISO's wholesale markets. Working with state regulatory agencies, we conducted a detailed survey of existing DR programs, dynamic pricing tariffs, and their features in MISO states. Utilities were asked to provide information on advance notice requirements to customers, operational triggers used to call events (e.g. system emergencies, market conditions, local emergencies), use of these DR resources to meet planning reserves requirements, DR resource availability (e.g., seasonal, annual), participant incentive structures, and monitoring and verification (M&V) protocols. This report describes the results of this comprehensive survey and discusses policy implications for integrating legacy retail DR programs and dynamic pricing tariffs into organized wholesale markets. Survey responses from 37 MISO members and 4 non-members provided information on 141 DR programs and dynamic pricing tariffs with a peak load reduction potential of 4,727 MW of retail DR resource. Major findings of this study area:- About 72percent of available DR is from interruptible rate tariffs offered to large commercial and industrial customers, while direct load control (DLC) programs account for ~;;18percent. Almost 90percent of the DR resources included in this survey are provided by investor-owned utilities. - Approximately, 90percent of the DR resources are available with less than

  1. Towards better GHG emissions savings with use of ISO GHG standards

    International Nuclear Information System (INIS)

    Chan Kook Weng

    2010-01-01

    The 15th Conference of Parties (COP 15) at Copenhagen, Denmark in December 2009 highlighted the need to combat climate change by facing the challenge of committing to reducing our emissions at all three levels with locally appropriate mitigation actions (LAMAs) at the local level to be linked to the nationally appropriate mitigation actions (NAMAs) and then contribute onwards to globally appropriate mitigation actions (GAMAs). The aim is to find solutions for both adaptation and mitigation by ensuring sufficient means are made available to support such efforts. This is because the world in entering a new phase that will be characterised by green growth in business. Thus be it agriculture that uses local knowledge of specific crop and livestock varieties to help in secure food supply, bio-energy, transport, industries, there must be policies to understand ecosystem-based to link people, biodiversity, energy, water and carbon so as to be more resilient and adaptable to the need for a low carbon economy in todays society.Climate change therefore affects organisations in many areas and they include legal compliance, carbon market, corporate social responsibility and sustainable development. Promoting sustainability requires making efficient use of energy, water and natural resources, decrease in waste load through recycling and streamlining the processes leading to everything that decreases their CO 2 and water footprints. Currently there are many GHG schemes and programmes and the issues centres around compatibility, costs and most importantly credibility. Achieving real GHG emissions reduction requires controlled and verified emissions reductions and quantification that are sound and verifiable. Thanks to the development of the ISO suite of standards on GHG and related matters, the use of these harmonised standards has given the assurance that a tonne of carbon is a tonne of carbon be it in Malaysia, Mali or Mongolia.The use of these standards like ISO 14064 Part 1

  2. Crystallization and preliminary X-ray analysis of the HA3 component of Clostridium botulinum type C progenitor toxin

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Toshio; Tonozuka, Takashi; Kotani, Mao; Obata, Kanae [Department of Applied Biological Science, Tokyo University of Agriculture and Technology, 3-5-8 Saiwai-cho, Fuchu-shi, Tokyo 183-8509 (Japan); Oguma, Keiji [Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, 2-5-1 Shikata-cho, Okayama 700-8558 (Japan); Nishikawa, Atsushi, E-mail: nishikaw@cc.tuat.ac.jp [Department of Applied Biological Science, Tokyo University of Agriculture and Technology, 3-5-8 Saiwai-cho, Fuchu-shi, Tokyo 183-8509 (Japan); CREST, Japan Science and Technology Agency (Japan)

    2007-12-01

    HA3, a 70 kDa haemagglutinating protein, is a precursor form of HA3a and HA3b, the subcomponents of Clostridium botulinum type C 16S progenitor toxin. In this report, recombinant HA3 protein was overexpressed in Escherichia coli, purified and crystallized. HA3, a 70 kDa haemagglutinating protein, is a precursor form of HA3a and HA3b, the subcomponents of Clostridium botulinum type C 16S progenitor toxin. In this report, recombinant HA3 protein was overexpressed in Escherichia coli, purified and crystallized. Diffraction data were collected to 2.6 Å resolution and the crystal belonged to the hexagonal space group P6{sub 3}. Matthews coefficient and self-rotation function calculations indicate that there is probably one molecule of HA3 in the asymmetric unit. A search for heavy-atom derivatives has been undertaken.

  3. A Modified ELISA Accurately Measures Secretion of High Molecular Weight Hyaluronan (HA) by Graves' Disease Orbital Cells

    Science.gov (United States)

    Krieger, Christine C.

    2014-01-01

    Excess production of hyaluronan (hyaluronic acid [HA]) in the retro-orbital space is a major component of Graves' ophthalmopathy, and regulation of HA production by orbital cells is a major research area. In most previous studies, HA was measured by ELISAs that used HA-binding proteins for detection and rooster comb HA as standards. We show that the binding efficiency of HA-binding protein in the ELISA is a function of HA polymer size. Using gel electrophoresis, we show that HA secreted from orbital cells is primarily comprised of polymers more than 500 000. We modified a commercially available ELISA by using 1 million molecular weight HA as standard to accurately measure HA of this size. We demonstrated that IL-1β-stimulated HA secretion is at least 2-fold greater than previously reported, and activation of the TSH receptor by an activating antibody M22 from a patient with Graves' disease led to more than 3-fold increase in HA production in both fibroblasts/preadipocytes and adipocytes. These effects were not consistently detected with the commercial ELISA using rooster comb HA as standard and suggest that fibroblasts/preadipocytes may play a more prominent role in HA remodeling in Graves' ophthalmopathy than previously appreciated. PMID:24302624

  4. DIFFERENCES IN MANAGER ASSESSMENTS OF ISO 14000 STANDARD IMPLEMENTATION IN TURKEY

    Directory of Open Access Journals (Sweden)

    Sıtkı Gözlü

    2005-12-01

    Full Text Available This study reports the results of a survey about the improvements achieved as result of ISO 14000 Environmental Management System (EMS standard implementation and the differences of improvements with respect to firm characteristics. A survey has been conducted in order to explain the improvements related to environmental management process and overall firm performance. The survey involved sixty-six enterprises implementing ISO 14000 EMS standard in Turkey. In order to assess improvements obtained from ISO 14000 EMS implementation, statements related to environmental management process and overall firm performance indicators have been prepared. The statements in this study are relevant to previous research. A factor analysis was employed to determine the factors of the variables explaining improvements. Nine factors have been identified related to achieved improvements, such as establishment of pro-active environmental management system, effectiveness in resource utilization, effectiveness of process control, relationships with industry and government, meeting expectations of stakeholders, demonstration of social responsibility, profitability, productivity, and competitiveness. Then, a T- test was conducted to determine the differences of managers’ assessments with respect to certain firm characteristics. The findings have shown that there are differences in the assessments of improvements achieved as a result of ISO 14000 EMS standard implementation with respect to sales volume, foreign-capital possession, and ISO 14000 EMS standard implementation. On the other hand, industrial sector, age of establishment, and export orientation are not statistically significant for the differences in the assessments of improvements.

  5. Specification of Energy Assessment Methodologies to Satisfy ISO 50001 Energy Management Standard

    Science.gov (United States)

    Kanneganti, Harish

    Energy management has become more crucial for industrial sector as a way to lower their cost of production and in reducing their carbon footprint. Environmental regulations also force the industrial sector to increase the efficiency of their energy usage. Hence industrial sector started relying on energy management consultancies for improvements in energy efficiency. With the development of ISO 50001 standard, the entire energy management took a new dimension involving top level management and getting their commitment on energy efficiency. One of the key requirements of ISO 50001 is to demonstrate continual improvement in their (industry) energy efficiency. The major aim of this work is to develop an energy assessment methodology and reporting format to tailor the needs of ISO 50001. The developed methodology integrates the energy reduction aspect of an energy assessment with the requirements of sections 4.4.3 (Energy Review) to 4.4.6 (Objectives, Targets and Action Plans) in ISO 50001 and thus helping the facilities in easy implementation of ISO 50001.

  6. The relevance of the ISO26000 social responsibility issues to the Hong Kong construction industry

    Directory of Open Access Journals (Sweden)

    Lisa Robyn Barnes

    2013-09-01

    Full Text Available CorporateSocial Responsibility (CSR, the responsibility of a corporation for theimpacts of its decisions on society and the environment, originated as a termin the 1950’s (Carroll 1999. However, ISO 26000 (ISO 2010“Guidance on Social Responsibility” published in November 2010, redefines “SocialResponsibility” (“SR” broadly, by reference to SR principles, core subjectsand issues. The Hong Kong Construction Industry (“HKCI” sector is critical to Hong Kong’s economy, accounting for5.6% of the GDP and 9.2% of employment in 1999 (Tang 2001. In 2011, the gross value of constructionwork by main contractors amounted to HK$128.53 billion and contributed HK$65.4 billion (HKGov 2013to the total GDP of HK$1,823.2 billion (3.6% (HKTDC 2013.The aim of this research is toinvestigate which ISO 26000 CSR issues are relevantto HKCI firms. Theprinciple findings are that: the reported level of HKCI CSR activity relativeto the 7 core subject of ISO 26000 is a function of company size; many SME’sconsider that many of the ISO 26000 SR issues are irrelevant to them; but forthe large construction contractors, reputation, legislation and or regulation andcorporate culture are drivers of improvements in CSR in the HKCI.

  7. Evaluation of the Effectiveness of ISO14001 on Hospital Wastes Management Using AHP in Tehran Hospitals

    Directory of Open Access Journals (Sweden)

    Mohammad Noorisepehr

    2014-06-01

    Full Text Available Background: Lack of enough supervision, wrong and partial planning in the part of hospital residuals management cause high volume of production from variety of residuals which controlling them impose high costs to every society. In order to improve hospital wastes management, implementing a system of environmental management like ISO14001 can improve the environmental performance of organization and introduce the ways of solving problems to managers. The main objective of this study was to identify and prioritize the effective factors in the implementation of ISO 14001 and the benefits of its implementation in hospitals of Tehran. Methods: In this study, after the identification of success factors and benefits of ISO 14001 implementation in hospitals of Tehran, the method of analytical hierarchy process is used in order to understand the importance and relative priority of these successful important factors and their benefits. Results: Results show that the most important successful factors, based on the importance, are management commitment, education and training, communications and community relations and documentation and control.  Also, the most important benefits, of ISO 14001 implementation, are cost reduction in waste management, increasing the awareness and commitment of staff, risk management practices improvement and work process and procedures improvement. Conclusion: Findings of the study indicate that which success factors of ISO 14001 requires more attention by managers and are in priority while implementing them.

  8. ISOE: an international occupational exposure database and communications network for dose optimisation

    International Nuclear Information System (INIS)

    Robinson, I.F.; Lazo, E.

    1995-01-01

    The Information System on Occupational Exposure (ISOE) was launched by the Nuclear Energy Agency (NEA) of the Organisation for Economic Co-operation and Development (OECD) on 1 January 1992 to facilitate the communication of dosimetry and ALARA implementation data among nuclear facilities around the world. Members of ISOE include 51 utilities from 17 countries and regulators from 11 countries, with four regional technical centres administering the system and a Steering Group which manages the work. ISOE includes three databases and a communications network at several levels. The three databases NEA1, NEA2 and NEA3 include varying levels of details, with NEA3 being the most detailed giving task and site specific ALARA practices and experiences. Utility membership of ISOE gives full access to the databases whereas regulators have more limited access. This paper reviews the current status of participation, describes the three databases and the communications network. Some dose data showing trends in particular countries are presented as well as dose data relating to operation cycle length and outage length. The advantages of membership are described, and it is concluded that ISOE holds the potential for both dose and cost savings. (author)

  9. Predicting the quantifiable impacts of ISO 50001 on climate change mitigation

    Energy Technology Data Exchange (ETDEWEB)

    McKane, Aimee; Therkelsen, Peter; Scodel, Anna; Rao, Prakash; Aghajanzadeh, Arian; Hirzel, Simon; Zhang, Ruiqin; Prem, Richard; Fossa, Alberto; Lazarevska, Ana M.; Matteini, Marco; Schreck, Bettina; Allard, Fabian; Villegal Alcántar, Noé; Steyn, Karel; Hürdoğan, Ertaç; Björkman, Thomas; O' Sullivan, John

    2017-08-01

    The ISO 50001-Energy management standard provides a continual improvement framework for organizations to reduce their energy consumption, which in the industrial and commercial (service) sectors, accounts for nearly 40% of global greenhouse gas emissions. Reducing this energy consumption will be critical for countries to achieve their national greenhouse gas reduction commitments. Several national policies already support ISO 50001; however, there is no transparent, consistent process to estimate the potential impacts of its implementation. This paper presents the ISO 50001 Impacts Methodology, an internationally-developed methodology to calculate these impacts at a national, regional, or global scale suitable for use by policymakers. The recently-formed ISO 50001 Global Impacts Research Network provides a forum for policymakers to refine and encourage use of the methodology. Using this methodology, a scenario with 50% of projected global industrial and service sector energy consumption under ISO 50001 management by 2030 would generate cumulative primary energy savings of approximately 105 EJ, cost savings of nearly US $700 billion (discounted to 2016 net present value), and 6500 million metric tons (Mt) of avoided CO2 emissions. The avoided annual CO2 emissions in 2030 alone are equivalent to removing 210 million passenger vehicles from the road.

  10. Implementation of ISO 22000 in Romanian Companies: Motivations, Difficulties and Key Benefits

    Directory of Open Access Journals (Sweden)

    Carmen Păunescu

    2018-02-01

    Full Text Available The development of well-designed food safety management systems that take into consideration the potential risks and threats to an organization and their associated impacts to business operations should be a key goal for each organization operating in the food supply chain. This study provides quantitative empirical evidence about the motivations for implementing a food safety management system based on ISO 22000. By employing factor analysis and multiple linear regression, it analyses the benefits that the ISO 22000 certified companies gained through certification, as well as the main constraints that may prevent the adoption of the standard in the food industry. The survey is based on a sample of Romanian companies distributed at all levels of the food chain, but mainly at the production level. While there exist external pressures that lead companies to adopt a food safety management system based on ISO 22000, the motivations that are most relevant in this decision are generally internal in nature. The results of our study identify three major benefits of ISO 22000 certification: food safety improvement and provision of safer products, reduction of illness and other risks arising from food and improvement of consumers’ confidence. Also, it points out three constraints limiting the dissemination and use of ISO 22000: employees’ qualification, costs associated with food safety management system implementation and legal requirements.

  11. An ISO 9001 quality management system in a hospital: bureaucracy or just benefits?

    Science.gov (United States)

    van den Heuvel, Jaap; Koning, Lida; Bogers, Ad J J C; Berg, Marc; van Dijen, Monique E M

    2005-01-01

    To describe how The Red Cross Hospital in Beverwijk, The Netherlands implemented an ISO 9000 quality management system throughout the entire organisation, obtained an ISO 9002:1994 and subsequently an ISO 9001:2000 certificate. First, a global implementation plan was written concerning the process obtaining in each department. Once improved, each process was subjected to a procedure, and specific protocols effected. On completion the Quality Manual was put together. Quality management was completed by implementing an internal audit system involving 50 co-workers. A number of advantages are found from using ISO. The focus on patients has been re-established. All processes are identified and subject to continuous improvement. Performance measurements were introduced and give an integrated picture of results. Measurements subsequently lead to improvement of quality of care and to quality system improvements. The documentation system serves the organization's needs without leading to bureaucracy. Positive effects on patient safety could be demonstrated compared with ten other hospitals. Given the need for adequate quality management tools in health care and the need for demonstrating quality, the positive effects reported in this article show how ISO is expected to become more prevalent in health-care organisations.

  12. KSC Center Director Bridges addresses the audience at an ISO 9001 certification ceremony

    Science.gov (United States)

    1998-01-01

    Center Director Roy Bridges speaks to KSC employees at the ISO certification ceremony held at the Training Auditorium. Bridges was presented an ISO 9001 certificate and plaque awarded to KSC by Det Norske Veritas (DNV), Inc., an international ISO certification organization. ISO 9001 comprises the most detailed, comprehensive set of standard requirements for quality programs established by the International Standards Organization. The presentation followed a successful independent audit by DNV of the KSC Management System in May of this year. The third-party auditors examined about 20 elements of KSC's system, including management responsibility, design control, documentation, test and inspection, and corrective action procedures. DNV found that KSC met or exceeded the stringent quality standards in all areas. KSC will use this certification as a tool to improve an already world- class team. All NASA centers are required by NASA Administrator Daniel S. Goldin to be ISO 9001 registered by September 1999. NASA is the first federal agency to seek the quality certification. Next to Bridges is Heidi Hollingsworth, with the Center for Independent Living, who uses American Sign Language for any hearing-impaired employees in the audience.

  13. KSC Center Director Bridges accepts an ISO 9001 certification plaque from DNV

    Science.gov (United States)

    1998-01-01

    Center Director Roy Bridges (right) displays the 2000th ISO Certificate Plaque he was given by Dalton Lyon (left) of Det Norske Veritas (DNV), Inc., an international ISO certification organization, at a ceremony at KSC. The plaque is a representation of the ISO 9001 certification awarded to KSC by DNV. ISO 9001 comprises the most detailed, comprehensive set of standard requirements for quality programs established by the International Standards Organization. The presentation followed a successful independent audit by DNV of the KSC Management System in May of this year. The third-party auditors examined about 20 elements of KSC's system, including management responsibility, design control, documentation, test and inspection, and corrective action procedures. DNV found that KSC met or exceeded the stringent quality standards in all areas. KSC will use this certification as a tool to improve an already world- class team. All NASA centers are required by NASA Administrator Daniel S. Goldin to be ISO 9001 registered by September 1999. NASA is the first federal agency to seek the quality certification.

  14. KSC Center Director Bridges accepts an ISO 9001 certificate from DNV

    Science.gov (United States)

    1998-01-01

    Center Director Roy Bridges displays the ISO 9001 certificate he was awarded by Det Norske Veritas (DNV), Inc., an international ISO certification organization, at a ceremony at KSC. Dalton Lyon of DNV made the presentation, which included a 2000th ISO Certificate Plaque. ISO 9001 comprises the most detailed, comprehensive set of standard requirements for quality programs established by the International Standards Organization. The presentation followed a successful independent audit by DNV of the KSC Management System in May of this year. The third-party auditors examined about 20 elements of KSC's system, including management responsibility, design control, documentation, test and inspection, and corrective action procedures. DNV found that KSC met or exceeded the stringent quality standards in all areas. KSC will use this certification as a tool to improve an already world-class team. All NASA centers are required by NASA Administrator Daniel S. Goldin to be ISO 9001 registered by September 1999. NASA is the first federal agency to seek the quality certification.

  15. PRAPI: post-transcriptional regulation analysis pipeline for Iso-Seq.

    Science.gov (United States)

    Gao, Yubang; Wang, Huiyuan; Zhang, Hangxiao; Wang, Yongsheng; Chen, Jinfeng; Gu, Lianfeng

    2018-05-01

    The single-molecule real-time (SMRT) isoform sequencing (Iso-Seq) based on Pacific Bioscience (PacBio) platform has received increasing attention for its ability to explore full-length isoforms. Thus, comprehensive tools for Iso-Seq bioinformatics analysis are extremely useful. Here, we present a one-stop solution for Iso-Seq analysis, called PRAPI to analyze alternative transcription initiation (ATI), alternative splicing (AS), alternative cleavage and polyadenylation (APA), natural antisense transcripts (NAT), and circular RNAs (circRNAs) comprehensively. PRAPI is capable of combining Iso-Seq full-length isoforms with short read data, such as RNA-Seq or polyadenylation site sequencing (PAS-seq) for differential expression analysis of NAT, AS, APA and circRNAs. Furthermore, PRAPI can annotate new genes and correct mis-annotated genes when gene annotation is available. Finally, PRAPI generates high-quality vector graphics to visualize and highlight the Iso-Seq results. The Dockerfile of PRAPI is available at http://www.bioinfor.org/tool/PRAPI. lfgu@fafu.edu.cn.

  16. Adsorption and separation of n/iso-pentane on zeolites: A GCMC study.

    Science.gov (United States)

    Fu, Hui; Qin, Hansong; Wang, Yajun; Liu, Yibin; Yang, Chaohe; Shan, Honghong

    2018-03-01

    Separation of branched chain hydrocarbons and straight chain hydrocarbons is very important in the isomerization process. Grand canonical ensemble Monte Carlo simulations were used to investigate the adsorption and separation of iso-pentane and n-pentane in four types of zeolites: MWW, BOG, MFI, and LTA. The computation of the pure components indicates that the adsorption capacity is affected by physical properties of zeolite, like pore size and structures, and isosteric heat. In BOG, MFI and LTA, the amount of adsorption of n-pentane is higher than iso-pentane, while the phenomenon is contrary in MWW. For a given zeolite, a stronger adsorption heat corresponds to a higher loading. In the binary mixture simulations, the separation capacity of n-and iso-pentane increases with the elevated pressure and the increasing iso-pentane composition. The adsorption mechanism and competition process have been examined. Preferential adsorption contributions prevail at low pressure, however, the size effect becomes important with the increasing pressure, and the relatively smaller n-pentane gradually competes successfully in binary adsorption. Among these zeolites, MFI has the best separation performance due to its high shape selectivity. This work helps to better understand the adsorption and separation performance of n- and iso-pentane in different zeolites and explain the relationship between zeolite structures and adsorption performance. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Study on the changes of serum HA and CG levels in several diseases besides liver disorders

    Energy Technology Data Exchange (ETDEWEB)

    Zhiping, Lu; Yunbao, Ma; Xiaoyi, Zhang; Weihua, Lv [Changshu Hospital Attached to Medical College of Yangzhou Univ., Changshu No.2 People' s Hospital, Changshu (China)

    2005-12-15

    Objective: To study the changes of serum hyaluronic acid (HA) and cholyglycine (CG) in several diseases besides liver disorders. Methods: Serum HA and CG levels were measured with RIA in 78 patients with chronic liver diseases (with 70 controls), (84 patients with primary hepatic carcinoma ), 70 pediatric patients with various infections diseases (with 40 controls), 50 pediatric patients with recurrent respiratory infection (RRI, with 30 controls) and 428 pregnant women ( with 60 controls). In addition, RBC C{sub 3}b receptor ratio (RBCC{sub 3} bRR) and RBC immune-complex ratio (RBCICR) (both with yeast rosette method) as well as serum IgG,IgM,IgA,C{sub 3} levels (with immunoturbidity test) were examined in the 50 RRI pediatric patients, ALT levels were examined in the 70 pediatric patients with infectious diseases and SF examined in the 78 patients with chronic liver diseases. Results: The serum CG, HA and SF levels in the three groups of patients with chronic liver diseases ( CPH, CAH, Cirrhosis) were significantly higher than those in the controls (all P<0.01 ) with the exception of HA in CPH patients (P > 0.05). In patients with hepatic carcinoma, the CG and HA levels were positively correlated with the mortality at 4 months (P < 0.05). Among pregnant women, serum levels of HA and CG were significantly higher during the second and third trimesters (P<0.05-0.01) than those in the controls but not so during the first trimester. In the pediatric patients with infectious diseases, CG and HA levels were significantly higher in all these patients (P<0.01) with the only exception of HA in patients with mumps (P>0.05). For ALT, levels only increased in patients with hepatitis and typhoid fever with none in bacillary dysentery and mumps. In pediatric patients with RRI, RBCC{sub 3}bRR (%), CG, C{sub 3}, IgG levels were significantly higher than those in controls (P<0.05 ) with no significant differences in the case of RBCICR (%), HA, IgM and IgA levels (P>0

  18. ISO 14001 y variables económicas, ¿hay alguna relación? Análisis de las empresas certificadas del sector cerámico español

    Directory of Open Access Journals (Sweden)

    Peiró-Signes, A.

    2013-02-01

    Full Text Available The increased in the adoption of formally environmental certified practices through environmental management systems is a provable fact. Its implementation, which has a high cost for the companies, is expected to generate benefits, although the relation between the implementation of ISO 14001 and its influence on the improvement of economic indicators over time has not been documented. This paper analyzes the relation between the implementation of an environmental management system, the ISO 14001, and economic performance in the short, medium and long term for the companies of the Spanish ceramic tile industry. It explores the economic indicators for each of the 66 manufacturing companies which have implemented the aforementioned standard from 1996 until 2009 through a comparison with a control group. Results show that ISO 14001 does not affect the economic results of the studied companies. We have not found significant differences in the operating income values, neither in the increase in revenues in the long term in any of the three analyzed periods, contrary to the expected results.

    Es un hecho constatable el incremento de la adopción de prácticas medioambientales certificadas de manera formal a través de sistemas de gestión medioambiental. De su implantación, que tiene un elevado coste para las empresas, se espera la generación de beneficios, aunque no se ha documentado aún si existe relación entre la implantación de la ISO 14001 y su influencia en la mejora de los indicadores económicos a lo largo del tiempo. En este trabajo se analiza la relación entre la implantación de un sistema de gestión medioambiental, la ISO 14001, y el comportamiento económico en el corto, medio y largo plazo de las empresas del sector cerámico español. Se estudian los indicadores económicos para cada una de las 66 empresas productoras que han implantado la citada norma desde 1996 hasta el año 2009 a través de la comparación con su grupo

  19. Is ISO 14001 a Gateway to More Advanced Voluntary Action? A Case for Green Supply Chain Management

    OpenAIRE

    Arimura, Toshi H.; Darnall, Nicole; Katayama, Hajime

    2009-01-01

    Using Japanese facility-level data, we estimate the effects of ISO 14001 certification on the promotion of more advanced practices, namely green supply chain management (GSCM). Our results show that ISO 14001 promotes GSCM practices, in that facilities with environmental management systems (EMS) certified to ISO 14001 are 40 percent more likely to assess their suppliers’ environmental performance and 50 percent more likely to require that their suppliers undertake specific environmental pract...

  20. The most common nonconformities encountered during the assessments of medical laboratories in Hong Kong using ISO 15189 as accreditation criteria

    OpenAIRE

    Ho, Bella; Ho, Eric

    2012-01-01

    Introduction: ISO 15189 was a new standard published in 2003 for accrediting medical laboratories. We believe that some requirements of the ISO 15189 standard are especially diffi cult to meet for majority of laboratories. The aim of this article was to present the frequency of nonconformities to requirements of the ISO 15189 accreditation standard, encountered during the assessments of medical laboratories in Hong Kong, during 2004 to 2009. Materials and methods: Nonconformities reported ...

  1. Promotion of environmental managements systems (EMAS, ISO 14.000) in the Italian small and medium industries. The applied experiences achieved by ENEA; Promozione dei sistemi di gestione ambientale (EMAS, ISO 14.000) nelle piccole e medie imprese italiane. Le esperienze applicative dell `ENEA

    Energy Technology Data Exchange (ETDEWEB)

    Andriola, Luca; Brunetti, Nicola; Caropreso, Gaetano; Luciani, Roberto [ENEA, Centro Ricerche Casaccia, Rome (Italy). Dipt. Ambiente

    1998-03-01

    EMAS (Environmental Management and Audit Scheme) introduced by the Regulation n. 1836/93, is one of the new tools activated by the European Community to overcome the old `Command and Control` philosophy and adopt an approaching policy in the `Moral suasion` logic. It is based on the sharing out of the responsibility, dialogue and action agreed upon by the concerned parties on the basis of impartial and reliable information. EMAS has voluntary character and presents many analogies with ISO 14.000 international system with which a deeper integration is being attempted for a revision of the Regulation. In the frame of present national and international situation, the report shows the recording path of an EMAS site and the experiences achieved up to now particularly by ENEA. [Italiano] L`EMAS (Environmental Management and Audit Scheme), introdotto con il Rergolamento n. 1836/93, rappresenta uno dei nuovi strumenti che la Comunita` Europea ha attivato per superare la vecchia logica del `Command and Control` (Imponi e Sorveglia) e passare ad una nuova filosofia di approccio nella logica della `Moral suasion` (persuasione morale) per un rapporto basato sulla ripartizione delle responsabilita` attraverso un dialogo e un`azione concertata tra le parti interessate sulla base di un`informazione obiettiva ed affidabile. Lo strumento EMAS ha carattere di volontarieta` e presenta profonde analogie con il sistema internazionale ISO 14.000 con il quale si sta tentando, a livello di revisione del Regolamento EMAS, una integrazione piu` profonda. Nel rapporto vengono illustrati, nel quadro dell`attuale situazione nazionale ed internazionale, il percorso di registrazione di un sito EMAS e le esperienza finora attuare con particolare riferimento a quelle dell`ENEA.

  2. Wear characterization of nano-hydroxyapatite with addition of titanium (HA-Ti)

    Science.gov (United States)

    Rosmamuhamadani, R.; Arawi, A. Z. O.; Talari, M. K.; Mahat, M. M.; Bonnia, N. N.; Sabrina; Yahaya, M.; Sulaiman, S.; Ismail, M. I. S.

    2018-04-01

    Hydroxyapatite (Ca10 (PO4)6(OH)2, HA), is an attractive material of an inorganic compound whose chemical composition and crystallographic structures are similar to the composition of the bone. A natural source such as egg shells is composed of 94 wt. % of calcium carbonate (CaCO3), which can be calcined as calcium oxide (CaO) by the calcinations process. The efficient temperature to produce CaO is 900 °C for 2 hours. The synthesis of nano-HA was done by the mixing the diammonium phosphate (DAP) and calcium hydroxide (Ca(OH)2) and subjected into a microwave for 30 minutes at 1100 W irradiation power. Ball milling process was used for 30 minutes to mix the nano-HA with different compositions of titanium. These were pressed to form pallets by hand hydraulic pump (force=2300 psi). The pallets then were sintered at 1200 °C with the heating rate of 3 °C/min for 2 hours. The pallets were tested by several mechanical testing including hardness, compression strength and wear. From the results, HA-25wt. %Ti composite gave the highest hardness, compression and coefficient of friction for wear test values which were 89.6 Hv, 82.5MPa and 0.76μ respectively. It showed that by adding Ti to nano-HA, the mechanical properties of nano-HA could be enhanced. The microstructure analyses by optical micrograph showed that nano-HA-Ti particles displayed shape likes needle morphology. The particles showed the high tendency to form the agglomerations.

  3. Enhancement of mucosal immune responses by chimeric influenza HA/SHIV virus-like particles

    International Nuclear Information System (INIS)

    Guo Lizheng; Lu Xiaoyan; Kang, S.-M.; Chen Changyi; Compans, Richard W.; Yao Qizhi

    2003-01-01

    To enhance mucosal immune responses using simian/human immunodeficiency virus-like particles (SHIV VLPs), we have produced novel phenotypically mixed chimeric influenza HA/SHIV VLPs and used them to immunize C57BL/6J mice intranasally. Antibody and cytotoxic T-cell (CTL) responses as well as cytokine production in both systemic and mucosal sites were compared after immunization with SHIV VLPs or chimeric HA/SHIV VLPs. By using enzyme-linked immunosorbent assay (ELISA), the levels of serum IgG and mucosal IgA to the HIV envelope protein (Env) were found to be highest in the group immunized with chimeric HA/SHIV VLPs. Furthermore, the highest titer of serum neutralizing antibody against HIV Env was found with the group immunized with chimeric HA/SHIV VLPs. Analysis of the IgG1/IgG2a ratio indicated that a T H 1-oriented immune response resulted from these VLP immunizations. HA/SHIV VLP-immunized mice also showed significantly higher CTL responses than those observed in SHIV VLP-immunized mice. Moreover, a MHC class I restricted T-cell activation ELISPOT assay showed a mixed type of T H 1/T H 2 cytokines in the HA/SHIV VLP-immunized mice, indicating that the chimeric VLPs can enhance both humoral and cellular immune responses to the HIV Env protein at multiple mucosal and systemic sites. The results indicate that incorporation of influenza HA into heterotypic VLPs may be highly effective for targeting vaccines to mucosal surfaces

  4. Preparation and characterization of NiW-nHA composite catalyst for hydrocracking

    Science.gov (United States)

    Zhou, Gang; Hou, Yongzhao; Liu, Lei; Liu, Hongru; Liu, Can; Liu, Jing; Qiao, Huiting; Liu, Wenyong; Fan, Yubo; Shen, Shituan; Rong, Long

    2012-11-01

    The synthesis, characterization and catalytic capability of the NiW-nano-hydroxyapatite (NiW-nHA) composite were investigated in this paper. The NiW-nHA catalyst was prepared by a co-precipitation method. Then Fourier transform infrared (FT-IR) spectroscopy, transmission electron microscopy (TEM), X-ray diffraction (XRD) and energy dispersive spectroscopy (EDX) were used to analyze this material. In addition, the catalytic capacity of the NiW-nHA composite was also examined by FT-IR and gas chromatography (GC). The results of FT-IR analysis indicated that Ni, W and nHA combined closely. TEM observation revealed that this catalyst was needle shaped and the crystal retained a nanometer size. XRD data also suggested that a new phase of CaWO4 appeared and the lattice parameters of nHA changed in this system. nHA was the carrier of metals. The rates of Ni/W-loading were 73.24% and 65.99% according to the EDX data, respectively. Furthermore, the conversion of 91.88% Jatropha oil was achieved at 360 °C and 3 MPa h-1 over NiW-nHA catalyst. The straight chain alkanes ranging from C15 to C18 were the main components in the production. The yield of C15-C18 alkanes was up to 83.56 wt%. The reaction pathway involved hydrocracking of the C&z.dbd;C bonds of these triglycerides from Jatropha oil. This paper developed a novel non-sulfided catalyst to obtain a ``green biofuel'' from vegetable oil.

  5. Sugar-binding sites of the HA1 subcomponent of Clostridium botulinum type C progenitor toxin.

    Science.gov (United States)

    Nakamura, Toshio; Tonozuka, Takashi; Ide, Azusa; Yuzawa, Takayuki; Oguma, Keiji; Nishikawa, Atsushi

    2008-02-22

    Clostridium botulinum type C 16S progenitor toxin contains a hemagglutinin (HA) subcomponent, designated HA1, which appears to play an important role in the effective internalization of the toxin in gastrointestinal epithelial cells and in creating a broad specificity for the oligosaccharide structure that corresponds to various targets. In this study, using the recombinant protein fused to glutathione S-transferase, we investigated the binding specificity of the HA1 subcomponent to sugars and estimated the binding sites of HA1 based on X-ray crystallography and soaking experiments using various sugars. N-Acetylneuraminic acid, N-acetylgalactosamine, and galactose effectively inhibited the binding that occurs between glutathione S-transferase-HA1 and mucins, whereas N-acetylglucosamine and glucose did not inhibit it. The crystal structures of HA1 complex with N-acetylneuraminic acid, N-acetylgalactosamine, and galactose were also determined. There are two sugar-binding sites, sites I and II. Site I corresponds to the electron densities noted for all sugars and is located at the C-terminal beta-trefoil domain, while site II corresponds to the electron densities noted only for galactose. An aromatic amino acid residue, Trp176, at site I has a stacking interaction with the hexose ring of the sugars. On the other hand, there is no aromatic residue at site II; thus, the interaction with galactose seems to be poor. The double mutant W176A at site I and D271F at site II has no avidity for N-acetylneuraminic acid but has avidity for galactose. In this report, the binding specificity of botulinum C16S toxin HA1 to various sugars is demonstrated based on its structural features.

  6. Sintering behavior and property of bioglass modified HA-Al2O3 composite

    Directory of Open Access Journals (Sweden)

    Wang Li-li

    2012-01-01

    Full Text Available The bioglass modified HA-Al2O3 composites were successfully fabricated by mixing HA, synthesized by wet chemical method between precursor materials H3PO4 and Ca(OH2, with 25wt% Al2O3 and different content of bioglass (5%, 25%, 45%, 65wt% respectively, with a mole fraction of 53.9%SiO2, 22.6%Na2O, 21.8%CaO, and 1.7wt%P2O5, sintered in air at various temperatures (750-950°C for 2h. when the content of bioglass is below 45wt% in the composite, HA decomposes completely and transforms to β-TCP. The main phase in this case are β-TCP, Al2O3 and Ca3(AlO32.When the content of bioglass is above 45wt% in the composite, the decomposition of HA to β-TCP is suppressed and the main phases in this case are Al2O3 and HA, DCP□CaHPO4□ and β-TCP, which almost have the same chemical composition, forming ternary-glass phase, and have better bioactive than pure HA. It can also be found that at the certain addition of bioglass, the higher sintered temperature, the bigger volume density and flexural strength of the composite are, but when the sintered temperature reaches 950°C, they decrease. This modified HA-Al2O3 composites by calcium silicate glass have a much lower sintering temperature and decrease the production cost much.

  7. Isothermal Crystallization Kinetics of HDPE/HA Compounds Irradiated with Sterilization Doses of Gamma Rays

    International Nuclear Information System (INIS)

    Albano, C.

    2006-01-01

    The objective of this work was to study the isothermal crystallization of High Density Polyethylene/Hydroxyapatite nanocomposites, with 2 and 5 ppc of HA, irradiated with 25 kGy (sterilization dose) of γ-Ray from a 60 C o source, at a rate of 4.8 kGy/h in air and at room temperature. The selected crystallization temperatures were 118, 117, 116 and 115 degree. The crystallization kinetics was analyzed using the Avrami's model whose parameters were optimized using a non-linear regression technique. Regression results show that the Avrami exponent varies between 1.8 and 1.5, meaning that the spherulitic growth is mainly two dimensional. Values for specific crystallization constant 'k' were found to be higher for HDPE/HA compounds than for pure HDPE, clearly indicating the presence of an HA nucleation effect. It was also observed that values for the specific crystallization constant 'k' decreases with increasing temperatures, being this effect more noticeable for HDPE/HA compounds than for pure HDPE. Regarding to irradiated samples, their 'k' values were found to be lower than those for non irradiated samples, the difference getting more significant with decreasing crystallization temperature. Simulation of experimental data with the Avrami's model show a clear influence of the crystallization temperature, the HA content in the sample and the amount of applied radiation. It was also observed that the Avrami model correlates satisfactorily experimental data for not irradiated samples of pure HDPE and HDPE/HA compounds at the highest crystallization (T c ). However, as the crystallization temperature decreases, the values simulated with the Avrami model increasingly deviate from experimental data, specifically at the highest values of the relative crystallinity. This effect is even stronger on irradiated samples of HDPE and HDPE/HA compounds

  8. Contrasting predictability of summer monsoon rainfall ISOs over the northeastern and western Himalayan region: an application of Hurst exponent

    Science.gov (United States)

    Mukherjee, Sandipan

    2017-09-01

    Due to heterogeneous nonlinear forcing of complex geomorphological features, predictability of monsoon rainfall 10-90-day intra-seasonal oscillations (ISO) over the complex terrain of northeastern and western Himalayan region (NEH and WH) remained poorly quantified. Using 72 and 61 number of station observations of monsoon rainfall ISOs of NEH and WH, respectively, this study attempts to investigate variation in the regional scale predictability of monsoon rainfall ISOs with respect to changing geomorphological features and monsoon rainfall characteristics. In view of the bimodal nonlinear dynamical structure of monsoon rainfall ISO, the fractal dynamical Hurst exponent-based predictability indices are estimated as an indicator of predictability for station observations of NEH and WH, and relationships with elevations, slopes, aspects, and average numbers of occurrences of long (short) spell of active (break) phases are investigated. Results show 10-90-day ISOs are anti-persistent throughout the IHR, although, predictability of 10-90-day ISOs is higher over the NEH region than WH. Predictabilities of ISOs are found to decrease with increasing elevation and slope for both NEH and WH regions. Predictabilities of ISOs over both regions are also found to increase linearly as the number of occurrences of monsoon rainfall ISO phases (active/break) increases.

  9. Analysis of ISO/IEC 17025 for establishment of KOLAS (Korea Laboratory Accreditation Scheme) quality assurance system

    International Nuclear Information System (INIS)

    Nam, Ji Hee

    2000-12-01

    Besides one existent accredited lab, radioactive material chemical analysis lab, five test laboratories and two calibration labs are under plan to acquire the accreditation from KOLAS. But the current Quality Manual was developed according to ISO Guide 25 that was superceded by ISO/IEC 17025. Since it is tailored to the radioactive material chemical analysis lab, a number of requirements of the Manual are not applicable to the labs other than radioactive material chemical analysis lab. Through the analysis of ISO/IEC 17025, a model of quality system was established which is not only consistent with ISO/IEC 17025 but reflective of the KAERI's situation

  10. [Reform of the Law DIN EN ISO 9001:2000. Commentary on the new requirements on quality management systems].

    Science.gov (United States)

    Eckert, H; Böhmer, K

    2000-09-01

    Since January this year the German translation of the third draft to the reform of the DIN EN ISO 9000 is available. The draft reveals an approximation to the models of Business Excellence. Most important changes are a far stronger customer orientation, orientation on the processes and resource management. The norms DIN EN ISO 9002 and 9003 have been removed, ISO 8402 has been integrated in the reformed DIN EN ISO 9000. Apart from that the compatibility with other management systems has been improved. It was the aim of the reform to improve the applicability for all types of business, products and services.

  11. Performance improvement with ISO 9001:2000: a case of PKOC-II project

    Energy Technology Data Exchange (ETDEWEB)

    Behera, U.K.; Prasad, K.S.N. [Singareni Collieries Co. Ltd. (India)

    2006-07-01

    The present study is limited to the study of main step towards ISO 9001:2000 (QMS) development, implementation and improvements of PKOC-II project and the same are discussed. In line with increasing global concern for quality, environmental protection and occupational health and safety, Singareni Collieries Co. Ltd (SCCL) has taken the strategic decision to implement ISO 9001:2000 (QMS), ISO 14001:2004 EMS (environmental management system) and occupational health and safety assessment series 18001:1999 (OHSAS) at the PK OC-II project. This is the first project to implement all three management systems QMS, OHSAS, and EMS, in the Indian coal industry. 25 refs., 12 figs., 2 tabs.

  12. A fully customizable MATLAB Framework for MSA based on ISO 5725 Standard

    International Nuclear Information System (INIS)

    D’Aucelli, Giuseppe Maria; Giaquinto, Nicola; Mannatrizio, Sabino; Savino, Mario

    2017-01-01

    In this paper, a full featured MATLAB framework for Measurement System Analysis, fully compliant with the ISO 5725 Repeatability and Reproducibility (R and R) assessment is presented. While preserving the operations prescribed in the ISO standard, the software presents distinct improvements. First of all, all computations are made using exact closed-form formulae (instead of statistical tables) allowing a consistent analysis without limitations on the number of participating laboratories and measurements, and using custom significance levels of statistical tests. Second, a double threshold decision system for each test step has been implemented, helping the statistician to decide on the elimination of outliers/stragglers. Third, ANOVA analysis has been included. The software therefore, besides producing quickly and efficiently all the graphical and numerical results required in an inter-laboratory experiment, provide guidelines for properly updating the ISO 5725 standard. (paper)

  13. A study of ISO Solenoid Valve with static and dynamic characteristics

    International Nuclear Information System (INIS)

    Jeon, Y. S.; Ju, M. J.; Oh, Y. C.; Kim, D. S.

    2009-01-01

    The technology of ISO Solenoid Valves is now considered as a core technology in the fields of the production line of semi-conductor chips and the ISO fluid chips for medical applications. And ISO Solenoid Valves, which operate by compressed air, are characterized by high speed response, great repeatability and that the pressure on the cross sectional area of poppet is kept constant regardless of the fluctuation of the pressure exerted on the ports. The primary objective of this study is to compare the optimally designed Solenoid Valve with the actually produced one and to design a power saving circuit which can highly improve the efficiency by providing optimal current according to mechanical load.

  14. Iso-acoustic focusing of cells for size-insensitive acousto-mechanical phenotyping.

    Science.gov (United States)

    Augustsson, Per; Karlsen, Jonas T; Su, Hao-Wei; Bruus, Henrik; Voldman, Joel

    2016-05-16

    Mechanical phenotyping of single cells is an emerging tool for cell classification, enabling assessment of effective parameters relating to cells' interior molecular content and structure. Here, we present iso-acoustic focusing, an equilibrium method to analyze the effective acoustic impedance of single cells in continuous flow. While flowing through a microchannel, cells migrate sideways, influenced by an acoustic field, into streams of increasing acoustic impedance, until reaching their cell-type specific point of zero acoustic contrast. We establish an experimental procedure and provide theoretical justifications and models for iso-acoustic focusing. We describe a method for providing a suitable acoustic contrast gradient in a cell-friendly medium, and use acoustic forces to maintain that gradient in the presence of destabilizing forces. Applying this method we demonstrate iso-acoustic focusing of cell lines and leukocytes, showing that acoustic properties provide phenotypic information independent of size.

  15. Iso-acoustic focusing of cells for size-insensitive acousto-mechanical phenotyping

    DEFF Research Database (Denmark)

    Augustsson, Per; Karlsen, Jonas Tobias; Su, Hao-Wei

    2016-01-01

    Mechanical phenotyping of single cells is an emerging tool for cell classification, enabling assessment of effective parameters relating to cells' interior molecular content and structure. Here, we present iso-acoustic focusing, an equilibrium method to analyze the effective acoustic impedance...... of single cells in continuous flow. While flowing through a microchannel, cells migrate sideways, influenced by an acoustic field, into streams of increasing acoustic impedance, until reaching their cell-type specific point of zero acoustic contrast. We establish an experimental procedure and provide...... theoretical justifications and models for iso-acoustic focusing. We describe a method for providing a suitable acoustic contrast gradient in a cell-friendly medium, and use acoustic forces to maintain that gradient in the presence of destabilizing forces. Applying this method we demonstrate iso-acoustic...

  16. Study on the Evolution of the Current ISO Certifications in Romania

    Directory of Open Access Journals (Sweden)

    Teodor Socaciu

    2013-06-01

    Full Text Available To increase the efficiency and effectiveness of processes within an organization, ISO standards can help both large enterprises and small companies (SMEs, both in industrialized and in developing countries offering solutions and bringing considerable advantages in almost all existing fields. ISO certification brings a set of measures in the areas of an organization, be it about quality, environmental safety, food or protection and safety of personnel, this certification brings benefits both in the current processes and more importantly, the future development plans. In this paper, graphs showing the distributions of increasing certification, demonstrate that more and more companies in Romania have realized that, only implementing and certifying ISO standards, they will be successful in domestic and international market in terms of competition, in particular against European companies.

  17. Applying and extending ISO/TC42 digital camera resolution standards to mobile imaging products

    Science.gov (United States)

    Williams, Don; Burns, Peter D.

    2007-01-01

    There are no fundamental differences between today's mobile telephone cameras and consumer digital still cameras that suggest many existing ISO imaging performance standards do not apply. To the extent that they have lenses, color filter arrays, detectors, apertures, image processing, and are hand held, there really are no operational or architectural differences. Despite this, there are currently differences in the levels of imaging performance. These are driven by physical and economic constraints, and image-capture conditions. Several ISO standards for resolution, well established for digital consumer digital cameras, require care when applied to the current generation of cell phone cameras. In particular, accommodation of optical flare, shading non-uniformity and distortion are recommended. We offer proposals for the application of existing ISO imaging resolution performance standards to mobile imaging products, and suggestions for extending performance standards to the characteristic behavior of camera phones.

  18. Design of an Electronic Healthcare Record Server Based on Part 1 of ISO EN 13606

    Directory of Open Access Journals (Sweden)

    Tony Austin

    2011-01-01

    Full Text Available ISO EN 13606 is a newly approved standard at European and ISO levels for the meaningful exchange of clinical information between systems. Although conceived as an inter-operability standard to which existing electronic health record (EHR systems will transform legacy data, the requirements met and architectural approach reflected in this standard also make it a good candidate for the internal architecture of an EHR server. The authors have built such a server for the storage of healthcare records and demonstrated that it is possible to use ISO EN 13606 part 1 as the basis of an internal system architecture. The development of the system and some of the applications of the server are described in this paper. It is the first known operational implementation of the standard as an EHR system.

  19. ISO-9001: An approach to accreditation for an MTR facility: SAFARI-1 research reactor

    International Nuclear Information System (INIS)

    Piani, C.S.B.; Du Bruyn, J.F.B.

    2000-01-01

    The SAFARI-1 Research Reactor obtained ISO-9001 accreditation via the South African Bureau of Standards in September 1998. In view of the commercial applications of the reactor, the value of acquisition of the accreditation was considered against the cost of implementation of the Quality System. The criteria identified in the ISO-9001 standard were appraised and a superstructure derived for management of the generation and implementation of a suitable Quality Management System (QMS) for the fairly unique application of a nuclear research reactor. A Quality Policy was established, which formed the basis of the QMS against which the various requirements and/or standards were identified. In addition, since it was considered advantageous to incorporate the management controls of Conventional and Radiological Safety as well as Plant Maintenance and Environmental Management (ISO 14001), these aspects were included in the QMS. (author)

  20. Enhanced definition and required examples of common datum imposed by ISO standard

    Science.gov (United States)

    Yan, Yiqing; Bohn, Martin

    2017-12-01

    According to the ISO Geometrical Product Specifications (GPS), the establishment and definition of common datum for geometrical components are not fully defined. There are two main limitations of this standard. Firstly: the explications of ISO examples of common datums are not matched with their corresponding definitions, and secondly: a full definition of common datum is missing. This paper suggests a new approach for an enhanced definition and concrete examples of common datum and proposes a holistic methodology for establishment of common datum for each geometrical component. This research is based on the analysis of physical behaviour of geometrical components, orientation constraints and invariance classes of datums. This approach fills the definition gaps of common datum based on ISO GPS, thereby eliminating those deficits. As a result, an improved methodology for a fully functional defined definition of common datum was formulated.