WorldWideScience

Sample records for ha emitter count

  1. CalCOFI Larvae Counts, Scientific Names GO to HA

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for larvae captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  2. On the standardization of positron emitters by 4πγ counting

    International Nuclear Information System (INIS)

    Garcia-Torano, Eduardo; Peyres, Virginia; Roteta, Miguel

    2007-01-01

    This paper focuses on the application of the method known as ''4πγ counting'' to the standardization of positron emitters. Measurements and Monte Carlo simulations have been used to determine the optimal conditions of application. Two positron emitters ( 22 Na and 18 F) have been standardized, and the results are compared to those obtained by other methods. A good agreement has been found

  3. Few remarks on the absolute counting of {beta} emitters using 4 {pi} counter; Quelques remarques sur la mesure absolue des emetteurs {beta} au compteur 4 {pi}

    Energy Technology Data Exchange (ETDEWEB)

    Grinberg, B; Le Gallic, Y [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    This study looks to determinate the optimum experimental conditions which allow the best accuracy possible for the absolute counting of {beta} emitters when using a 4 {pi} counter. The study has been done with a 4 {pi} counter using source supports of 30 {mu}m thickness. The associated electronic circuit includes: high-voltage, a 1000 scale and a dead time preafier of 4x10{sup -4} {mu}s. In addition, a coincidence preamplifier - with 1 {mu}s resolution time - was added which permits to count the coincidence between the measuring channels. It compares the measurement accuracy and the absorption correction needed for different source supports including polymers thin films with and without metal coating. (M.P.)

  4. Emittance preservation

    Energy Technology Data Exchange (ETDEWEB)

    Kain, V; Arduini, G; Goddard, B; Holzer, B J; Jowett, J M; Meddahi, M; Mertens, T; Roncarolo, F; Schaumann, M; Versteegen, R; Wenninger, J [European Organization for Nuclear Research, Geneva (Switzerland)

    2012-07-01

    Emittance measurements during the LHC proton run 2011 indicated a blow-up of 20 % to 30 % from LHC injection to collisions. This presentation will show the emittance preservation throughout the different parts of the LHC cycle and discuss the current limitations on emittance determination. An overview of emittance preservation through the injector complex as function of bunch intensity will also be given. Possible sources for the observed blow-up and required tests in 2012 will be presented. Possible improvements of emittance diagnostics and analysis tools for 2012 will be shown.

  5. Nanodiamond Emitters of Single Photons

    Directory of Open Access Journals (Sweden)

    Vlasov I.I.

    2015-01-01

    Full Text Available Luminescence properties of single color centers were studied in nanodiamonds of different origin. It was found that single photon emitters could be realized even in molecularsized diamond (less than 2 nm capable of housing stable luminescent center “silicon-vacancy.” First results on incorporation of single-photon emitters based on luminescent nanodiamonds in plasmonic nanoantennas to enhance the photon count rate and directionality, diminish the fluorescence decay time, and provide polarization selectivity are presented.

  6. Assessment of beta-emitter radionuclides in biological samples using liquid scintillation counting. Application to the study of internal doses in molecular and cellular biology techniques

    International Nuclear Information System (INIS)

    Sierra, I.; Delgado, A.; Navarro, T.; Macias, M. T.

    2007-01-01

    The radioisotopic techniques used in Molecular and Cellular Biology involve external and internal irradiation risk. It is necessary to control the possible internal contamination associated to the development of these techniques. The internal contamination risk can be due to physical and chemical properties of the labelled compounds, aerosols generated during the performance technique. The aim of this work was to estimate the possible intake of specific beta emitters during the technique development and to propose the required criterions to perform Individual Monitoring. The most representative radioisotopic techniques were selected attending their potential risk of internal contamination. Techniques were analysed applying IAEA methodology according to the used activity in each technique. It was necessary to identify the worker groups that would require individual monitoring on the base of their specific risk. Different measurement procedures were applied to study the possible intake in group risk and more than 160 persons were measured by in vitro bioassay. (Author) 96 refs

  7. Beta emitter radionuclides (90Sr contamination in animal feed: validation and application of a radiochemical method by ultra low level liquid scintillation counting

    Directory of Open Access Journals (Sweden)

    Marco Iammarino

    2015-02-01

    Full Text Available 90Sr is considered as a dangerous contaminant of agri-food supply chains due to its chemical affinity with Calcium, which makes its absorption in bones easy. 90Sr accumulation in raw materials and then in final products is particularly significant in relationship to its ability to transfer into animal source products. The radionuclides transfer (137Cs and 90Sr from environment to forages and then to products of animal origin (milk, cow and pork meats was studied and evaluated in different studies, which were carried out in contaminated areas, from Chernobyl disaster until today. In the present work, the development and validation of a radiochemical method for the detection of 90Sr in different types of animal feed, and the application of this technique for routinely control activities, are presented. Liquid scintillation counting was the employed analytical technique, since it is able to determine very low activity concentrations of 90Sr (<0.01 Bq kg–1. All samples analysed showed a 90Sr contamination much higher than method detection limit (0.008 Bq kg–1. In particular, the highest mean activity concentration was registered in hay samples (2.93 Bq kg–1, followed by silage samples (2.07 Bq kg–1 and animal feeds (0.77 Bq kg–1. In fact, all samples were characterized by 90Sr activity concentrations much lower than reference limits. This notwithstanding, the necessity to monitor these levels was confirmed, especially considering that 90Sr is a possible carcinogen for human.

  8. Asymmetrical field emitter

    Science.gov (United States)

    Fleming, J.G.; Smith, B.K.

    1995-10-10

    A method is disclosed for providing a field emitter with an asymmetrical emitter structure having a very sharp tip in close proximity to its gate. One preferred embodiment of the present invention includes an asymmetrical emitter and a gate. The emitter having a tip and a side is coupled to a substrate. The gate is connected to a step in the substrate. The step has a top surface and a side wall that is substantially parallel to the side of the emitter. The tip of the emitter is in close proximity to the gate. The emitter is at an emitter potential, and the gate is at a gate potential such that with the two potentials at appropriate values, electrons are emitted from the emitter. In one embodiment, the gate is separated from the emitter by an oxide layer, and the emitter is etched anisotropically to form its tip and its asymmetrical structure. 17 figs.

  9. HA-Coated Implant

    DEFF Research Database (Denmark)

    Daugaard, Henrik; Søballe, Kjeld; Bechtold, Joan E

    2014-01-01

    of improving the fixation of implants. Of these, hydroxyapatite (HA) is the most widely used and most extensively investigated. HA is highly osseoconductive, and the positive effect is well documented in both basic and long-term clinical research [1–6]. This chapter describes experimental and clinical studies...

  10. Increased platelet count and reticulated platelets in recently symptomatic versus asymptomatic carotid artery stenosis and in cerebral microembolic signal-negative patient subgroups: results from the HaEmostasis In carotid STenosis (HEIST) study.

    Science.gov (United States)

    Murphy, S J X; Lim, S T; Kinsella, J A; Murphy, D; Enright, H M; McCabe, Dominick J H

    2018-02-23

    The pathophysiological mechanisms responsible for the disparity in stroke risk between asymptomatic and symptomatic carotid stenosis patients are not fully understood. The functionally important reticulated platelet fraction and reticulocytes could play a role. We performed a prospective, multi-centre, observational analytical study comparing full blood count parameters and platelet production/turnover/activation markers in patients with asymptomatic versus recently symptomatic moderate (≥ 50-69%) or severe (≥ 70-99%) carotid stenosis. Data from 34 asymptomatic patients were compared with 43 symptomatic patients in the 'early phase' (≤ 4 weeks) and 37 of these patients in the 'late phase' (≥ 3 months) after TIA/ischaemic stroke. Reticulated platelets were quantified by whole blood flow cytometry and reticulated platelets and red cell reticulocytes by 'automated assays' (Sysmex XE-2100™). Bilateral simultaneous transcranial Doppler ultrasound monitoring classified patients as micro-embolic signal (MES)+ve or MES-ve. Mean platelet count was higher in early (216 × 10 9 /L; P = 0.04) and late symptomatic (219 × 10 9 /L; P = 0.044) than asymptomatic patients (194 × 10 9 /L). Mean platelet volume was higher in early symptomatic than asymptomatic patients (10.8 vs. 10.45 fl; P = 0.045). Automated assays revealed higher % reticulated platelet fractions in early (5.78%; P < 0.001) and late symptomatic (5.11%; P = 0.01) than asymptomatic patients (3.48%). Red cell reticulocyte counts were lower in early (0.92%; P = 0.035) and late symptomatic (0.93%; P = 0.036) than asymptomatic patients (1.07%). The automated % reticulated platelet fraction was also higher in early symptomatic than asymptomatic MES-ve patients (5.7 vs. 3.55%; P = 0.001). The combination of increased platelet counts and a shift towards production of an increased population of larger, young, reticulated platelets could contribute to a higher risk of first or recurrent

  11. Cancer from internal emitters

    International Nuclear Information System (INIS)

    Boecker, B.B.; Griffith, W.C. Jr.

    1995-01-01

    Irradiation from internal emitters, or internally deposited radionuclides, is an important component of radiation exposures encountered in the workplace, home, or general environment. Long-term studies of human populations exposed to various internal emitters by different routes of exposure are producing critical information for the protection of workers and members of the general public. The purpose of this report is to examine recent developments and discuss their potential importance for understanding lifetime cancer risks from internal emitters. The major populations of persons being studied for lifetime health effects from internally deposited radionuclides are well known: Lung cancer in underground miners who inhaled Rn progeny, liver cancer from persons injected with the Th-containing radiographic contrast medium Thorotrast, bone cancer from occupational or medical intakes of 226 Ra or medical injections of 224 Ra, and thyroid cancer from exposures to iodine radionuclides in the environment or for medical purposes

  12. Low emittance photoinjectors

    International Nuclear Information System (INIS)

    Ferrario, Massimo

    2001-01-01

    Photon colliders require high charge polarized electron beams with very low normalized emittances, possibly lower than the actual damping rings design goals. Recent analytical and numerical efforts in understanding beam dynamics in RF photoinjectors have raised again the question as to whether the performances of an RF electron gun based injector could be competitive with respect to a damping ring. As a matter of discussion we report in this paper the most recent results concerning low emittance photoinjector designs: the production of polarized electron beams by DC and/or RF guns is illustrated together with space charge compensation techniques and thermal emittance effects. New ideas concerning multi-gun injection system and generation of flat beams by RF gun are also discussed

  13. Interlaboratory comparison of techniques for measuring lung burdens of low-energy X-ray emitters. Part of a coordinated programme on the calibration of burdens of inhaled plutonium by external counting

    International Nuclear Information System (INIS)

    Newton, D.; Fry, F.A.; Taylor, B.T.; Eagle, M.C.; Sharma, R.C.

    1978-02-01

    An interlaboratory exercise has been conducted to assess techniques of detection and calibration in the direct measurement of lung contamination with plutonium and other nuclides emitting only low-energy X-rays. Three volunteers, of small, intermediate and large physique, inhaled an aerosol incorporating Pd-103, a 20-keV X-ray emitter, and visited 13 other laboratories in the UK, Europe and North America. Participants in the exercise were asked to estimate each subject's lung content, using their procedures for assessing burdens of plutonium, and their estimates were compared with values derived independently from measurements of Cr-51, also incorporated in the inhaled particles, by gamma-ray spectrometry. Laboratories' calibration procedures were in most cases based on elaborate thorax phantoms, and these generally led to underestimates of the subjects' contents, in some instances by a factor of three or more; only one such laboratory produced estimates in satisfactory agreement with the independently-known values. The ''phoswich'' detectors, employed by most participants, appeared to be more sensitive than gas counters. If a standard configuration were required, offering the highest sensitivity in most situations, the choice would be a pair of 12-cm diameter phoswich detectors viewing the left and right anterior surfaces of the upper thorax. No improvement in sensitivity would result from increasing the size, although larger units may offer other advantages

  14. FACET Emittance Growth

    Energy Technology Data Exchange (ETDEWEB)

    Frederico, J; Hogan, M.J.; Nosochkov, Y.; Litos, M.D.; Raubenheimer, T.; /SLAC

    2011-04-05

    FACET, the Facility for Advanced Accelerator and Experimental Tests, is a new facility being constructed in sector 20 of the SLAC linac primarily to study beam driven plasma wakefield acceleration. The FACET beamline consists of a chicane and final focus system to compress the 23 GeV, 3.2 nC electron bunches to {approx}20 {micro}m long and {approx}10 {micro}m wide. Simulations of the FACET beamline indicate the short-duration and large, 1.5% rms energy spread beams may suffer a factor of four emittance growth from a combination of chromaticity, incoherent synchrotron radiation (ISR), and coherent synchrotron radiation (CSR). Emittance growth is directly correlated to head erosion in plasma wakefield acceleration and is a limiting factor in single stage performance. Studies of the geometric, CSR, and ISR components are presented. Numerical calculation of the rms emittance can be overwhelmed by long tails in the simulated phase space distributions; more useful definitions of emittance are given. A complete simulation of the beamline is presented as well, which agrees with design specifications.

  15. FACET Emittance Growth

    International Nuclear Information System (INIS)

    Frederico, Joel

    2011-01-01

    FACET, the Facility for Advanced Accelerator and Experimental Tests, is a new facility being constructed in sector 20 of the SLAC linac primarily to study beam driven plasma wakefield acceleration. The FACET beamline consists of a chicane and final focus system to compress the 23 GeV, 3.2 nC electron bunches to ∼20 (micro)m long and ∼10 (micro)m wide. Simulations of the FACET beamline indicate the short-duration and large, 1.5% rms energy spread beams may suffer a factor of four emittance growth from a combination of chromaticity, incoherent synchrotron radiation (ISR), and coherent synchrotron radiation (CSR). Emittance growth is directly correlated to head erosion in plasma wakefield acceleration and is a limiting factor in single stage performance. Studies of the geometric, CSR, and ISR components are presented. Numerical calculation of the rms emittance can be overwhelmed by long tails in the simulated phase space distributions; more useful definitions of emittance are given. A complete simulation of the beamline is presented as well, which agrees with design specifications.

  16. Mishima jo ha kyu

    Directory of Open Access Journals (Sweden)

    Matteo Casari

    2012-01-01

    Full Text Available Abstract – IT La grandezza artistica di Mishima si è espressa attraverso una eterogenea gamma di linguaggi tra i quali il teatro – nella drammaturgia ma anche nella saggistica, regia, recitazione e direzione di compagnia – ha avuto un ruolo di primo piano. Al pari di un uomo di scena Mishima inaugura, a partire dagli anni ’50, un processo di attenzione al proprio corpo come possibile, anzi necessario, veicolo di estrinsecazione etico-estetica tanto da poter istituire l’equazione corpo-teatro quale snodo profondo del suo processo creativo. Il corpo sognato e ottenuto da Mishima attraverso l’addestramento nel kendo, in altre arti marziali e nel body building si conformava ad un ideale estetico di matrice greco-classica assai lontano dal corpo teatrale nipponico. Il corpo come luogo di elaborazione e strumento di espressione autentica da realizzare con impegno, però, lo legano profondamente alle esperienze nascenti – tra gli anni ’50 e ’60 – delle avanguardie teatrali giapponesi. La metafora teatrale è spesso usata nella lettura critica del Mishima uomo e artista con accezione deteriore: un personaggio che dà spettacolo di sé con ripetute provocazioni tra le quali il suicidio del 25 novembre 1970 non sarebbe che l’esempio ultimo e più estremo. La costruzione di sé come personaggio, invece, sembrerebbe corrispondere ad una ben più profonda e meditata necessità di comporre la propria vita in una sapiente messa in scena di classica perfezione: i principi della scansione ritmico formale del jo ha kyu, pilastro teorico del teatro no codificato da Zeami tra XIV e XV secolo, offrono un valido modello di riferimento. Abstract – EN Mishima’s artistic greatness has been expressed through a diverse range of languages among wich theater – in dramaturgy as well as in written essays, as a director, performer and in company direction – played a central role. As a true front-man, Mishima – starting from the 50’s

  17. Low-emittance Storage Rings

    CERN Document Server

    Wolski, Andrzej

    2014-01-01

    The effects of synchrotron radiation on particle motion in storage rings are discussed. In the absence of radiation, particle motion is symplectic, and the beam emittances are conserved. The inclusion of radiation effects in a classical approximation leads to emittance damping: expressions for the damping times are derived. Then, it is shown that quantum radiation effects lead to excitation of the beam emittances. General expressions for the equilibrium longitudinal and horizontal (natural) emittances are derived. The impact of lattice design on the natural emittance is discussed, with particular attention to the special cases of FODO-, achromat- and theoretical-minimum-emittance-style lattices. Finally, the effects of betatron coupling and vertical dispersion (generated by magnet alignment and lattice tuning errors) on the vertical emittance are considered.

  18. Rare Earth Garnet Selective Emitter

    Science.gov (United States)

    Lowe, Roland A.; Chubb, Donald L.; Farmer, Serene C.; Good, Brian S.

    1994-01-01

    Thin film Ho-YAG and Er-YAG emitters with a platinum substrate exhibit high spectral emittance in the emission band (epsilon(sub lambda) approx. = 0.75, sup 4)|(sub 15/2) - (sup 4)|(sub 13/2),for Er-YAG and epsilon(sub lambda) approx. = 0.65, (sup 5)|(sub 7) - (sup 5)|(sub 8) for Ho-YAG) at 1500 K. In addition, low out-of-band spectral emittance, epsilon(sub lambda) less than 0.2, suggest these materials would be excellent candidates for high efficiency selective emitters in thermophotovoltaic (TPV) systems operating at moderate temperatures (1200-1500 K). Spectral emittance measurements of the thin films were made (1.2 less than lambda less than 3.0 microns) and compared to the theoretical emittances calculated using measured values of the spectral extinction coefficient. In this paper we present the results for a new class of rare earth ion selective emitters. These emitters are thin sections (less than 1 mm) of yttrium aluminum garnet (YAG) single crystal with a rare earth substitutional impurity. Selective emitters in the near IR are of special interest for thermophotovoltaic (TPV) energy conversion. The most promising solid selective emitters for use in a TPV system are rare earth oxides. Early spectral emittance work on rare earth oxides showed strong emission bands in the infrared (0.9 - 3 microns). However, the emittance outside the emission band was also significant and the efficiency of these emitters was low. Recent improvements in efficiency have been made with emitters fabricated from fine (5 - 10 microns) rare earth oxide fibers similar to the Welsbach mantle used in gas lanterns. However, the rare earth garnet emitters are more rugged than the mantle type emitters. A thin film selective emitter on a low emissivity substrate such as gold, platinum etc., is rugged and easily adapted to a wide variety of thermal sources. The garnet structure and its many subgroups have been successfully used as hosts for rare earth ions, introduced as substitutional

  19. Spherical proton emitters

    International Nuclear Information System (INIS)

    Berg, S.; Semmes, P.B.; Nazarewicz, W.

    1997-01-01

    Various theoretical approaches to proton emission from spherical nuclei are investigated, and it is found that all the methods employed give very similar results. The calculated decay widths are found to be qualitatively insensitive to the parameters of the proton-nucleus potential, i.e., changing the potential parameters over a fairly large range typically changes the decay width by no more than a factor of ∼3. Proton half-lives of observed heavy proton emitters are, in general, well reproduced by spherical calculations with the spectroscopic factors calculated in the independent quasiparticle approximation. The quantitative agreement with experimental data obtained in our study requires that the parameters of the proton-nucleus potential be chosen carefully. It also suggests that deformed proton emitters will provide invaluable spectroscopic information on the angular momentum decomposition of single-proton orbitals in deformed nuclei. copyright 1997 The American Physical Society

  20. Dosimetry of internal emitters

    International Nuclear Information System (INIS)

    Anon.

    1982-01-01

    The Dosimetry of Internal Emitter Program endeavors to refine the correlation between radiation dose and observed biological effects. The program is presently engaged in the development of studies that will demonstrate the applicability of microdosimetry models developed under the Microdosimetry of Internal Sources Program. The program also provides guidance and assistance to Pacific Northwest Laboratory's Biology Department in the dosimetric analysis of internally deposited radionuclides. This report deals with alpha particle dosimetry plutonium 239 inhalation, and in vitro studies of chromosomal observations

  1. Nonintercepting emittance monitor

    International Nuclear Information System (INIS)

    Miller, R.H.; Clendenin, J.E.; James, M.B.; Sheppard, J.C.

    1983-08-01

    A nonintercepting emittance monitor is a helpful device for measuring and improving particle beams in accelerators and storage rings as it allows continuous monitoring of the beam's distribution in phase space, and perhaps closed loop computer control of the distributions. Stripline position monitors are being investigated for use as nonintercepting emittance monitors for a beam focused by a FODO array in the first 100 meters of our linear accelerator. The technique described here uses the signal from the four stripline probes of a single position monitor to measure the quadrupole mode of the wall current in the beam pipe. This current is a function of the quadrupole moment of the beam, sigma 2 /sub x/ - sigma 2 /sub y/. In general, six independent measurements of the quadrupole moment are necessary to determine the beam emittance. This technique is dependent on the characteristically large variations of sigma 2 /sub x/ - sigma 2 /sub y/ in a FODO array. It will not work in a focusing system where the beam is round at each focusing element

  2. Analysis of low energy beta-emitters

    International Nuclear Information System (INIS)

    Murphy, D.L.

    1979-10-01

    A survey was made of the instruments used for the determination of low energy beta radioactivity. Techniques commonly used are gas flow proportional counting, liquid scintillation counting, solid scintillation counting, and internal ionization chamber counting, solid state detector counting, and radiochemical separation followed by counting using one of the preceeding techniques. The first four techniques were examined and compared with each other. The sensitivities of the techniques were compared on the basis of the detection limits quoted for instruments described in the technical and reviewed literature. The detection limits were then related to the occupational and public individual maximum levels for air and water. Attention is focused primarily on the continuous monitoring of air for 3 H and 85 Kr, a medium energy β-emitter. It is clear that several continuous air monitoring instruments are readily available for measuring low energy β concentrations, even in presence of certain other activity, at occupational levels. However, these instruments do not typically have sensitivities comparable to the public individual levels. Moreover, their capabilities for giving results in real time and for differentiating among the radionuclides actually present is limited

  3. RBC count

    Science.gov (United States)

    ... by kidney disease) RBC destruction ( hemolysis ) due to transfusion, blood vessel injury, or other cause Leukemia Malnutrition Bone ... slight risk any time the skin is broken) Alternative Names Erythrocyte count; Red blood cell count; Anemia - RBC count Images Blood test ...

  4. Monolithic multinozzle emitters for nanoelectrospray mass spectrometry

    Science.gov (United States)

    Wang, Daojing [Daly City, CA; Yang, Peidong [Kensington, CA; Kim, Woong [Seoul, KR; Fan, Rong [Pasadena, CA

    2011-09-20

    Novel and significantly simplified procedures for fabrication of fully integrated nanoelectrospray emitters have been described. For nanofabricated monolithic multinozzle emitters (NM.sup.2 emitters), a bottom up approach using silicon nanowires on a silicon sliver is used. For microfabricated monolithic multinozzle emitters (M.sup.3 emitters), a top down approach using MEMS techniques on silicon wafers is used. The emitters have performance comparable to that of commercially-available silica capillary emitters for nanoelectrospray mass spectrometry.

  5. Low emittance electron storage rings

    Science.gov (United States)

    Levichev, E. B.

    2018-01-01

    Low-emittance electron (positron) beams are essential for synchrotron light sources, linear collider damping rings, and circular Crab Waist colliders. In this review, the principles and methods of emittance minimization are discussed, prospects for developing relativistic electron storage rings with small beam phase volume are assessed, and problems related to emittance minimization are examined together with their possible solutions. The special features and engineering implementation aspects of various facilities are briefly reviewed.

  6. Emittance growth in rf linacs

    International Nuclear Information System (INIS)

    Jameson, R.A.

    1979-01-01

    As the space-charge limit is approached, the current that can be accelerated in an rf linac and the output emittance that can be expected are discussed. The role of the envelope equations to estimate limits is outlined. The results of numerical experiments to explore general properties of emittance growth are given

  7. Beam phase space and emittance

    International Nuclear Information System (INIS)

    Buon, J.

    1990-12-01

    The classical and elementary results for canonical phase space, the Liouville theorem and the beam emittance are reviewed. Then, the importance of phase portraits to obtain a geometrical description of motion is emphasized, with examples in accelerator physics. Finally, a statistical point of view is used to define beam emittance, to study its law of approximate conservation and to treat two particular examples

  8. Counting carbohydrates

    Science.gov (United States)

    Carb counting; Carbohydrate-controlled diet; Diabetic diet; Diabetes-counting carbohydrates ... Many foods contain carbohydrates (carbs), including: Fruit and fruit juice Cereal, bread, pasta, and rice Milk and milk products, soy milk Beans, legumes, ...

  9. Probable maximum flood on the Ha Ha River

    International Nuclear Information System (INIS)

    Damov, D.; Masse, B.

    1997-01-01

    Results of a probable maximum flood (PMF) study conducted for various locations along the Ha Ha river, a tributary of the Saguenay River, were discussed. The study was undertaken for use in the design and construction of new hydraulic structures for water supply for a pulp and paper facility, following the Saguenay Flood in July 1996. Many different flood scenarios were considered, including combinations of snow-melt with rainfall. Using computer simulations, it was shown that the largest flood flows were generated by summer-fall PMF. 5 refs., 12 figs

  10. Electrohydrodynamic emitters of ion beams

    International Nuclear Information System (INIS)

    Dudnikov, V.G.; Shabalin, A.L.

    1990-01-01

    Physical processes determining generation of ion beams with high emission current density in electrohydrodynamic emitters are considered. Electrohydrodynamic effects developing in ion emission features and kinetics of ion interaction in beams with high density are discussed. Factors determining the size of the emission zone, emission stability at high and low currents, cluster generation, increase of energy spread and decrease of brightness are analyzed. Problems on practical provision of stable EHD emitter functioning are considered. 94 refs.; 8 figs.; 1 tab

  11. Diamondoid monolayers as electron emitters

    Science.gov (United States)

    Yang, Wanli [El Cerrito, CA; Fabbri, Jason D [San Francisco, CA; Melosh, Nicholas A [Menlo Park, CA; Hussain, Zahid [Orinda, CA; Shen, Zhi-Xun [Stanford, CA

    2012-04-10

    Provided are electron emitters based upon diamondoid monolayers, preferably self-assembled higher diamondoid monolayers. High intensity electron emission has been demonstrated employing such diamondoid monolayers, particularly when the monolayers are comprised of higher diamondoids. The application of such diamondoid monolayers can alter the band structure of substrates, as well as emit monochromatic electrons, and the high intensity electron emissions can also greatly improve the efficiency of field-effect electron emitters as applied to industrial and commercial applications.

  12. A device for electron gun emittance measurement

    International Nuclear Information System (INIS)

    Aune, B.; Corveller, P.; Jablonka, M.; Joly, J.M.

    1985-05-01

    In order to improve the final emittance of the beam delivered by the ALS electron linac a new gun is going to be installed. To measure its emittance and evaluate the contribution of different factors to emittance growth we have developed an emittance measurement device. We describe the experimental and mathematical procedure we have followed, and give some results of measurements

  13. Counting cormorants

    DEFF Research Database (Denmark)

    Bregnballe, Thomas; Carss, David N; Lorentsen, Svein-Håkon

    2013-01-01

    This chapter focuses on Cormorant population counts for both summer (i.e. breeding) and winter (i.e. migration, winter roosts) seasons. It also explains differences in the data collected from undertaking ‘day’ versus ‘roost’ counts, gives some definitions of the term ‘numbers’, and presents two...

  14. Radiation emitter-detector package

    International Nuclear Information System (INIS)

    O'Brien, J.T.; Limm, A.C.; Nyul, P.; Tassia, V.S. Jr.

    1978-01-01

    Mounted on the metallic base of a radiation emitter-detector is a mounting block is a first projection, and a second projection. A radiation detector is on the first projection and a semiconductor electroluminescent device, i.e., a radiation emitter, is on the second projection such that the plane of the recombination region of the electroluminescent device is perpendicular to the radiation incident surface of the radiation detector. The electroluminescent device has a primary emission and a secondary emission in a direction different from the primary emission. A radiation emitter-detector package as described is ideally suited to those applications wherein the secondary radiation of the electroluminescent device is fed into a feedback circuit regulating the biasing current of the electroluminescent device

  15. Beam phase space and emittance

    International Nuclear Information System (INIS)

    Buon, J.

    1992-02-01

    The classical and elementary results for canonical phase space, the Liouville theorem and the beam emittance are reviewed. Then, the importance of phase portraits to obtain a geometrical description of motion is emphasized, with examples in accelerator physics. Finally, a statistical point of view is used to define beam emittance, to study its law of approximate conservation, with three particular examples, and to introduce a beam envelope-ellipse and the β-function, emphasing the statistical features of its properties. (author) 14 refs.; 11 figs

  16. Combustion powered thermophotovoltaic emitter system

    Energy Technology Data Exchange (ETDEWEB)

    McHenry, R.S. [Naval Academy, Annapolis, MD (United States). Naval Architecture, Ocean and Marine Engineering

    1995-07-01

    The US Naval Academy (USNA) has recently completed an engineering design project for a high temperature thermophotovoltaic (TPV) photon emitter. The final apparatus was to be portable, completely self contained, and was to incorporate cycle efficiency optimization such as exhaust stream recuperation. Through computer modeling and prototype experimentation, a methane fueled emitter system was designed from structural ceramic materials to fulfill the high temperature requirements necessary for high system efficiency. This paper outlines the engineering design process, discusses obstacles and solutions encountered, and presents the final design.

  17. Tower counts

    Science.gov (United States)

    Woody, Carol Ann; Johnson, D.H.; Shrier, Brianna M.; O'Neal, Jennifer S.; Knutzen, John A.; Augerot, Xanthippe; O'Neal, Thomas A.; Pearsons, Todd N.

    2007-01-01

    Counting towers provide an accurate, low-cost, low-maintenance, low-technology, and easily mobilized escapement estimation program compared to other methods (e.g., weirs, hydroacoustics, mark-recapture, and aerial surveys) (Thompson 1962; Siebel 1967; Cousens et al. 1982; Symons and Waldichuk 1984; Anderson 2000; Alaska Department of Fish and Game 2003). Counting tower data has been found to be consistent with that of digital video counts (Edwards 2005). Counting towers do not interfere with natural fish migration patterns, nor are fish handled or stressed; however, their use is generally limited to clear rivers that meet specific site selection criteria. The data provided by counting tower sampling allow fishery managers to determine reproductive population size, estimate total return (escapement + catch) and its uncertainty, evaluate population productivity and trends, set harvest rates, determine spawning escapement goals, and forecast future returns (Alaska Department of Fish and Game 1974-2000 and 1975-2004). The number of spawning fish is determined by subtracting subsistence, sport-caught fish, and prespawn mortality from the total estimated escapement. The methods outlined in this protocol for tower counts can be used to provide reasonable estimates ( plus or minus 6%-10%) of reproductive salmon population size and run timing in clear rivers. 

  18. Low emittance configuration for spear

    International Nuclear Information System (INIS)

    Blumberg, L.N.; Harris, J.; Stege, R.; Cerino, J.; Hettel, R.; Hofmann, A.; Liu, R.Z.; Wiedemann, H.; Winick, H.

    1985-01-01

    The quality of synchrotron radiation beams from SPEAR, in particular the brilliance of undulator radiation, can be improved significantly by reducing the emittance of the stored electron beam. A reduction of the horizontal emittance by a factor of 3.5 to a value of 130 nanometer-radians (nm-r) at 3 GeV has been achieved by using stronger focussing, mainly in the horizontal plane. The low emittance configuration also reduces the dispersion and vertical beta functions in the straight sections, making them more suitable for wigglers. The higher betatron tunes lead to a larger phase advance between the two kickers, which has to be corrected during injection by shunting current from some quadrupoles. The configuration was optimized within SPEAR hardware limitations and tested for dynamic aperture with the tracking program PATRICIA. After implementation of this scheme, beam was successfully injected and accumulated. The measured emittance of the stored beam was in agreement with calculations. Presently the configuration is being made operational

  19. Measuring emittances and sigma matrices

    International Nuclear Information System (INIS)

    Rees, J.; Rivkin, L.

    1984-03-01

    The method used for measuring emittance at the SLAC Linac and the linear collider damping ring is described. The basis of the method is derived using one two-by-two matrix to specify the state of the input beam (sigma matrix) and another to describe the lens-drift transport system (R-matrix)

  20. Shielding in ungated field emitter arrays

    Energy Technology Data Exchange (ETDEWEB)

    Harris, J. R. [U.S. Navy Reserve, Navy Operational Support Center New Orleans, New Orleans, Louisiana 70143 (United States); Jensen, K. L. [Code 6854, Naval Research Laboratory, Washington, D.C. 20375 (United States); Shiffler, D. A. [Directed Energy Directorate, Air Force Research Laboratory, Albuquerque, New Mexico 87117 (United States); Petillo, J. J. [Leidos, Billerica, Massachusetts 01821 (United States)

    2015-05-18

    Cathodes consisting of arrays of high aspect ratio field emitters are of great interest as sources of electron beams for vacuum electronic devices. The desire for high currents and current densities drives the cathode designer towards a denser array, but for ungated emitters, denser arrays also lead to increased shielding, in which the field enhancement factor β of each emitter is reduced due to the presence of the other emitters in the array. To facilitate the study of these arrays, we have developed a method for modeling high aspect ratio emitters using tapered dipole line charges. This method can be used to investigate proximity effects from similar emitters an arbitrary distance away and is much less computationally demanding than competing simulation approaches. Here, we introduce this method and use it to study shielding as a function of array geometry. Emitters with aspect ratios of 10{sup 2}–10{sup 4} are modeled, and the shielding-induced reduction in β is considered as a function of tip-to-tip spacing for emitter pairs and for large arrays with triangular and square unit cells. Shielding is found to be negligible when the emitter spacing is greater than the emitter height for the two-emitter array, or about 2.5 times the emitter height in the large arrays, in agreement with previously published results. Because the onset of shielding occurs at virtually the same emitter spacing in the square and triangular arrays, the triangular array is preferred for its higher emitter density at a given emitter spacing. The primary contribution to shielding in large arrays is found to come from emitters within a distance of three times the unit cell spacing for both square and triangular arrays.

  1. Continuous monitoring for airborne alpha emitters in a dusty environment

    International Nuclear Information System (INIS)

    Seiler, F.A.; Newton, G.J.; Guilmette, R.A.

    1988-01-01

    Disposal of radioactive wastes in underground facilities requires continuous monitoring for airborne radioactive materials, both on the surface and underground. In addition to a natural background of nonradioactive and radioactive aerosols, there may be a sizeable dust contribution from ongoing work such as mining and vehicular traffic. In the monitoring of alpha-emitting radionuclides, these aerosols may lead to self-absorption in the source and a deterioration of the energy spectrum of the detected alpha particles. In this paper, the influence of a realistic background aerosol on the performance of an alpha monitoring system is evaluated theoretically. It is shown that depositing alpha emitters and background aerosol on a surface for counting leads rapidly to a considerable loss of counts, a deterioration of the alpha spectra, an eventual saturation of the count rates, and interference from the natural background of Rn daughters

  2. Alpha particle emitters in medicine

    International Nuclear Information System (INIS)

    Fisher, D.R.

    1989-09-01

    Radiation-induced cancer of bone, liver and lung has been a prominent harmful side-effect of medical applications of alpha emitters. In recent years, however, the potential use of antibodies labeled with alpha emitting radionuclides against cancer has seemed promising because alpha particles are highly effective in cell killing. High dose rates at high LET, effectiveness under hypoxic conditions, and minimal expectancy of repair are additional advantages of alpha emitters over antibodies labeled with beta emitting radionuclides for cancer therapy. Cyclotron-produced astatine-211 ( 211 At) and natural bismuth-212 ( 212 Bi) have been proposed and are under extensive study in the United States and Europe. Radium-223 ( 223 Ra) also has favorable properties as a potential alpha emitting label, including a short-lived daughter chain with four alpha emissions. The radiation dosimetry of internal alpha emitters is complex due to nonuniformly distributed sources, short particle tracks, and high relative specific ionization. The variations in dose at the cellular level may be extreme. Alpha-particle radiation dosimetry, therefore, must involve analysis of statistical energy deposition probabilities for cellular level targets. It must also account fully for nonuniform distributions of sources in tissues, source-target geometries, and particle-track physics. 18 refs., 4 figs

  3. Counting probe

    International Nuclear Information System (INIS)

    Matsumoto, Haruya; Kaya, Nobuyuki; Yuasa, Kazuhiro; Hayashi, Tomoaki

    1976-01-01

    Electron counting method has been devised and experimented for the purpose of measuring electron temperature and density, the most fundamental quantities to represent plasma conditions. Electron counting is a method to count the electrons in plasma directly by equipping a probe with the secondary electron multiplier. It has three advantages of adjustable sensitivity, high sensitivity of the secondary electron multiplier, and directional property. Sensitivity adjustment is performed by changing the size of collecting hole (pin hole) on the incident front of the multiplier. The probe is usable as a direct reading thermometer of electron temperature because it requires to collect very small amount of electrons, thus it doesn't disturb the surrounding plasma, and the narrow sweep width of the probe voltage is enough. Therefore it can measure anisotropy more sensitively than a Langmuir probe, and it can be used for very low density plasma. Though many problems remain on anisotropy, computer simulation has been carried out. Also it is planned to provide a Helmholtz coil in the vacuum chamber to eliminate the effect of earth magnetic field. In practical experiments, the measurement with a Langmuir probe and an emission probe mounted to the movable structure, the comparison with the results obtained in reverse magnetic field by using a Helmholtz coil, and the measurement of ionic sound wave are scheduled. (Wakatsuki, Y.)

  4. Estimation of atomic interaction parameters by photon counting

    DEFF Research Database (Denmark)

    Kiilerich, Alexander Holm; Mølmer, Klaus

    2014-01-01

    Detection of radiation signals is at the heart of precision metrology and sensing. In this article we show how the fluctuations in photon counting signals can be exploited to optimally extract information about the physical parameters that govern the dynamics of the emitter. For a simple two......-level emitter subject to photon counting, we show that the Fisher information and the Cram\\'er- Rao sensitivity bound based on the full detection record can be evaluated from the waiting time distribution in the fluorescence signal which can, in turn, be calculated for both perfect and imperfect detectors...

  5. Counting Possibilia

    Directory of Open Access Journals (Sweden)

    Alfredo Tomasetta

    2010-06-01

    Full Text Available Timothy Williamson supports the thesis that every possible entity necessarily exists and so he needs to explain how a possible son of Wittgenstein’s, for example, exists in our world:he exists as a merely possible object (MPO, a pure locus of potential. Williamson presents a short argument for the existence of MPOs: how many knives can be made by fitting together two blades and two handles? Four: at the most two are concrete objects, the others being merely possible knives and merely possible objects. This paper defends the idea that one can avoid reference and ontological commitment to MPOs. My proposal is that MPOs can be dispensed with by using the notion of rules of knife-making. I first present a solution according to which we count lists of instructions - selected by the rules - describing physical combinations between components. This account, however, has its own difficulties and I eventually suggest that one can find a way out by admitting possible worlds, entities which are more commonly accepted - at least by philosophers - than MPOs. I maintain that, in answering Williamson’s questions, we count classes of physically possible worlds in which the same instance of a general rule is applied.

  6. Emittance control in linear colliders

    International Nuclear Information System (INIS)

    Ruth, R.D.

    1991-01-01

    Before completing a realistic design of a next-generation linear collider, the authors must first learn the lessons taught by the first generation, the SLC. Given that, they must make designs fault tolerant by including correction and compensation in the basic design. They must also try to eliminate these faults by improved alignment and stability of components. When these two efforts cross, they have a realistic design. The techniques of generation and control of emittance reviewed here provide a foundation for a design which can obtain the necessary luminosity in a next-generation linear collider

  7. Emittance Growth in the NLCTA First Chicane

    International Nuclear Information System (INIS)

    Sun, Yipeng

    2011-01-01

    In this paper, the emittance growth in the NLCTA (Next Linear Collider Test Accelerator) first chicane region is evaluated by simulation studies. It is demonstrated that the higher order fields of the chicane dipole magnet and the dipole corrector magnet (which is attached on the quadrupoles) are the main contributions for the emittance growth, especially for the case with a large initial emittance (γε 0 = 5 (micro)m for instance). These simulation results agree with the experimental observations.

  8. Production of alpha emitters for therapy

    International Nuclear Information System (INIS)

    Vucina, J.; Orlic, M.; Lukic, D.

    2006-01-01

    The basis for the introduction of alpha emitters into nuclear medical practice are their radiobiological properties. High LET values and short ranges in biological tissues are advantageous in comparison with nowadays most often used beta emitters, primarily 90 Y and 131 I. Given are the most important criteria for the introduction of a given radionuclide in the routine use. Shown are the procedures for the production of the most important alpha emitters 211 At, 212 Bi and 213 Bi. (author)

  9. Emittance measurements by variable quadrupole method

    International Nuclear Information System (INIS)

    Toprek, D.

    2005-01-01

    The beam emittance is a measure of both the beam size and beam divergence, we cannot directly measure its value. If the beam size is measured at different locations or under different focusing conditions such that different parts of the phase space ellipse will be probed by the beam size monitor, the beam emittance can be determined. An emittance measurement can be performed by different methods. Here we will consider the varying quadrupole setting method.

  10. Minimum emittance in TBA and MBA lattices

    Science.gov (United States)

    Xu, Gang; Peng, Yue-Mei

    2015-03-01

    For reaching a small emittance in a modern light source, triple bend achromats (TBA), theoretical minimum emittance (TME) and even multiple bend achromats (MBA) have been considered. This paper derived the necessary condition for achieving minimum emittance in TBA and MBA theoretically, where the bending angle of inner dipoles has a factor of 31/3 bigger than that of the outer dipoles. Here, we also calculated the conditions attaining the minimum emittance of TBA related to phase advance in some special cases with a pure mathematics method. These results may give some directions on lattice design.

  11. Minimum emittance in TBA and MBA lattices

    International Nuclear Information System (INIS)

    Xu Gang; Peng Yuemei

    2015-01-01

    For reaching a small emittance in a modern light source, triple bend achromats (TBA), theoretical minimum emittance (TME) and even multiple bend achromats (MBA) have been considered. This paper derived the necessary condition for achieving minimum emittance in TBA and MBA theoretically, where the bending angle of inner dipoles has a factor of 3 1/3 bigger than that of the outer dipoles. Here, we also calculated the conditions attaining the minimum emittance of TBA related to phase advance in some special cases with a pure mathematics method. These results may give some directions on lattice design. (authors)

  12. Hybrid emitter all back contact solar cell

    Science.gov (United States)

    Loscutoff, Paul; Rim, Seung

    2016-04-12

    An all back contact solar cell has a hybrid emitter design. The solar cell has a thin dielectric layer formed on a backside surface of a single crystalline silicon substrate. One emitter of the solar cell is made of doped polycrystalline silicon that is formed on the thin dielectric layer. The other emitter of the solar cell is formed in the single crystalline silicon substrate and is made of doped single crystalline silicon. The solar cell includes contact holes that allow metal contacts to connect to corresponding emitters.

  13. Emittance investigation of RF photo-injector

    CERN Document Server

    Yang Mao Rong; Li Zheng; Li Ming; Xu Zhou

    2002-01-01

    A high-power laser beam illuminates a photocathode surface placed on an end wall of an RF cavity. The emitted electrons are accelerated immediately to a relativistic energy by the strong RF find in the cavity. But space charge effect induces beam emittance growth especially near the cathode where the electrons are still nonrelativistic. The author analyzes the factors which lead the transverse emittance growth and method how to resolve this problem. After introducing solenoidal focusing near the photocathode, the beam emittance growth is suppressed dramatically. The beam emittance is given also after compensation and simulation results. The measurements show these results are coincident

  14. Emittance control in linear colliders

    International Nuclear Information System (INIS)

    Ruth, R.D.

    1991-05-01

    In this paper, we discuss the generation and control of the emittance in a next-generation linear collider. The beams are extracted from a damping ring and compressed in length by the first bunch compressor. They are then accelerated in a preaccelerator linac up to an energy appropriate for injection into a high gradient linac. In many designs this pre-acceleration is followed by another bunch compression to reach a short bunch. After acceleration in the linac, the bunches are finally focused transversely to a small spot. The proposed vertical beam sizes at the interaction point are the order of a few nanometers while the horizontal sizes are about a factor of 100 larger. This cross-sectional area is about a factor of 10 4 smaller than the SLC. However, the main question is: what are the tolerances to achieve such a small size, and how do they compare to present techniques for alignment and stability? These tolerances are very design dependent. Alignment tolerances in the linac can vary from 1 μm to 100 μm depending upon the basic approach. In this paper we discuss techniques of emittance generation and control which move alignment tolerances to the 100 μm range

  15. Coupling single emitters to quantum plasmonic circuits

    DEFF Research Database (Denmark)

    Huck, Alexander; Andersen, Ulrik Lund

    2016-01-01

    In recent years, the controlled coupling of single-photon emitters to propagating surface plasmons has been intensely studied, which is fueled by the prospect of a giant photonic nonlinearity on a nanoscaled platform. In this article, we will review the recent progress on coupling single emitters...

  16. Categorical counting.

    Science.gov (United States)

    Fetterman, J Gregor; Killeen, P Richard

    2010-09-01

    Pigeons pecked on three keys, responses to one of which could be reinforced after a few pecks, to a second key after a somewhat larger number of pecks, and to a third key after the maximum pecking requirement. The values of the pecking requirements and the proportion of trials ending with reinforcement were varied. Transits among the keys were an orderly function of peck number, and showed approximately proportional changes with changes in the pecking requirements, consistent with Weber's law. Standard deviations of the switch points between successive keys increased more slowly within a condition than across conditions. Changes in reinforcement probability produced changes in the location of the psychometric functions that were consistent with models of timing. Analyses of the number of pecks emitted and the duration of the pecking sequences demonstrated that peck number was the primary determinant of choice, but that passage of time also played some role. We capture the basic results with a standard model of counting, which we qualify to account for the secondary experiments. Copyright 2010 Elsevier B.V. All rights reserved.

  17. Emittance measurements of the CLIO electron beam

    Science.gov (United States)

    Chaput, R.; Devanz, G.; Joly, P.; Kergosien, B.; Lesrel, J.

    1997-02-01

    We have designed a setup to measure the transverse emittance at the CLIO accelerator exit, based on the "3 gradients" method. The beam transverse size is measured simply by scanning it with a steering coil across a fixed jaw and recording the transmitted current, at various quadrupole strengths. A code then performs a complete calculation of the emittance using the transfer matrix of the quadrupole instead of the usual classical lens approximation. We have studied the influence of various parameters on the emittance: Magnetic field on the e-gun and the peak current. We have also improved a little the emittance by replacing a mismatched pipe between the buncher and accelerating section to avoid wake-field effects; The resulting improvements of the emittance have led to an increase in the FEL emitted power.

  18. Liquid scintillation: Sample preparation and counting atypical emissions

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    Liquid scintillation sample preparation has the most published information but the least amount of definitive technical direction because the chemical and physical nature of the samples from biological investigations varies widely. This chapter discusses the following related topics: Aqueous Samples; Tissue Solubilizers; Absorption of 14 CO 2 ; Sample Combustion Methods; Heterogeneous Systems; Sample Preparation Problems (colored samples, chemiluminescence, photoluminescence, static electricity); Counting Various Types of Emitters; Counting Atypical Emissions. 2 refs., 2 figs

  19. Positron emitter labeled enzyme inhibitors

    International Nuclear Information System (INIS)

    Fowler, J.S.; MacGregor, R.R.; Wolf, A.P.; Langstrom, B.

    1990-01-01

    This invention involves a new strategy for imagining and mapping enzyme activity in the living human and animal body using positron emitter-labeled suicide enzyme inactivators or inhibitors which become covalently bound to the enzyme as a result of enzymatic catalysis. Two such suicide inactivators for monoamine oxidase have been labeled with carbon-11 and used to map the enzyme subtypes in the living human and animal body using PET. By using positron emission tomography to image the distribution of radioactivity produced by the body penetrating radiation emitted by carbon-11, a map of functionally active monoamine oxidase activity is obtained. Clorgyline and L-deprenyl are suicide enzyme inhibitors and irreversibly inhibit monoamine oxidase. When these inhibitors are labeled with carbon-11 they provide selective probes for monoamine oxidase localization and reactivity in vivo using positron emission tomography

  20. High current plasma electron emitter

    International Nuclear Information System (INIS)

    Fiksel, G.; Almagri, A.F.; Craig, D.

    1995-07-01

    A high current plasma electron emitter based on a miniature plasma source has been developed. The emitting plasma is created by a pulsed high current gas discharge. The electron emission current is 1 kA at 300 V at the pulse duration of 10 ms. The prototype injector described in this paper will be used for a 20 kA electrostatic current injection experiment in the Madison Symmetric Torus (MST) reversed-field pinch. The source will be replicated in order to attain this total current requirement. The source has a simple design and has proven very reliable in operation. A high emission current, small size (3.7 cm in diameter), and low impurity generation make the source suitable for a variety of fusion and technological applications

  1. Assessment of beta-emitter radionuclides in biological samples using liquid scintillation counting. Application to the study of internal doses in molecular and cellular biology techniques; Evaluacion en muestras biologicas de radionucleidos emisores beta mediante espectrometria de centelleo en fase liquida. Aplicaciones al estudio de dosis internas en tecnicas de investigacion de biologia molecular y celular

    Energy Technology Data Exchange (ETDEWEB)

    Sierra, I.; Delgado, A.; Navarro, T.; Macias, M. T.

    2007-07-01

    The radioisotopic techniques used in Molecular and Cellular Biology involve external and internal irradiation risk. It is necessary to control the possible internal contamination associated to the development of these techniques. The internal contamination risk can be due to physical and chemical properties of the labelled compounds, aerosols generated during the performance technique. The aim of this work was to estimate the possible intake of specific beta emitters during the technique development and to propose the required criterions to perform Individual Monitoring. The most representative radioisotopic techniques were selected attending their potential risk of internal contamination. Techniques were analysed applying IAEA methodology according to the used activity in each technique. It was necessary to identify the worker groups that would require individual monitoring on the base of their specific risk. Different measurement procedures were applied to study the possible intake in group risk and more than 160 persons were measured by in vitro bioassay. (Author) 96 refs.

  2. [Corrected count].

    Science.gov (United States)

    1991-11-27

    The data of the 1991 census indicated that the population count of Brazil fell short of a former estimate by 3 million people. The population reached 150 million people with an annual increase of 2%, while projections in the previous decade expected an increase of 2.48% to 153 million people. This reduction indicates more widespread use of family planning (FP) and control of fertility among families of lower social status as more information is being provided to them. However, the Ministry of Health ordered an investigation of foreign family planning organizations because it was suspected that women were forced to undergo tubal ligation during vaccination campaigns. A strange alliance of left wing politicians and the Roman Catholic Church alleges a conspiracy of international FP organizations receiving foreign funds. The FP strategies of Bemfam and Pro-Pater offer women who have little alternative the opportunity to undergo tubal ligation or to receive oral contraceptives to control fertility. The ongoing government program of distributing booklets on FP is feeble and is not backed up by an education campaign. Charges of foreign interference are leveled while the government hypocritically ignores the grave problem of 4 million abortions a year. The population is expected to continue to grow until the year 2040 and then to stabilize at a low growth rate of .4%. In 1980, the number of children per woman was 4.4 whereas the 1991 census figures indicate this has dropped to 3.5. The excess population is associated with poverty and a forsaken caste in the interior. The population actually has decreased in the interior and in cities with 15,000 people. The phenomenon of the drop of fertility associated with rural exodus is contrasted with cities and villages where the population is 20% less than expected.

  3. Laser treatment of plasma sprayed HA coatings

    NARCIS (Netherlands)

    Khor, KA; Vreeling, A; Dong, ZL; Cheang, P

    1999-01-01

    Laser treatment was conducted on plasma sprayed hydroxyapatite (HA) coatings using a Nd-YAG pulse laser. Various laser parameters were investigated. The results showed that the HA surface melted when an energy level of greater than or equal to 2 J and a spot size of 2 mm was employed during

  4. ha õhtu seltskonnalaud / Kaire Nurk

    Index Scriptorium Estoniae

    Nurk, Kaire, 1960-

    2005-01-01

    ha õhtusöömaaja teemast kunstis. Saksa kunstiajaloolase Horst Schwebeli poolt Leonardo da Vinci "Püha õhtusöömaaja" XX sajandi "töötlustes" välja toodud poliitilise agitatsiooni ja ühisest probleemist haaratud seltskonna kujutiste suunast. Laua kujutisest kunstis

  5. Photophysics of GaN single-photon emitters in the visible spectral range

    Science.gov (United States)

    Berhane, Amanuel M.; Jeong, Kwang-Yong; Bradac, Carlo; Walsh, Michael; Englund, Dirk; Toth, Milos; Aharonovich, Igor

    2018-04-01

    In this work, we present a detailed photophysical analysis of recently discovered, optically stable single-photon emitters (SPEs) in gallium nitride (GaN). Temperature-resolved photoluminescence measurements reveal that the emission lines at 4 K are three orders of magnitude broader than the transform-limited width expected from excited-state lifetime measurements. The broadening is ascribed to ultrafast spectral diffusion. The photophysical study on several emitters at room temperature (RT) reveals an average brightness of (427 ±215 )kCounts /s . Finally, polarization measurements from 14 emitters are used to determine visibility as well as dipole orientation of defect systems within the GaN crystal. Our results underpin some of the fundamental properties of SPEs in GaN both at cryogenic and RT, and define the benchmark for future work in GaN-based single-photon technologies.

  6. Cooling mechanical motion via vacuum effect of an ensemble of quantum emitters.

    Science.gov (United States)

    Nie, Wenjie; Chen, Aixi; Lan, Yueheng

    2015-11-30

    We design a hybrid optomechanical setup, in which an ensemble of quantum emitters is coupled with a movable mirror through vacuum interaction. The optical cavity is driven along with the quantum emitters and therefore the coupling between the cavity field and the ensemble determines the dynamics of the coupled system. In particular, we investigated the influence of the vacuum coupling strength on the effective frequency and the effective damping rate of the movable mirror, which shows that the vacuum interaction enhances greatly the effective damping rate. Further, the cooling characteristics of the mechanical resonator is analyzed in detail by counting the effective phonon number in the mirror's motion. It is found that the ground-state cooling of the mechanical motion can be approached in the bad cavity limit when the vacuum coupling is included. The dependence of the cooling of the mechanical motion on the parameters of the cavity and the quantum emitter is investigated in detail numerically.

  7. Beam diagnostics using an emittance measurement device

    International Nuclear Information System (INIS)

    Sarstedt, M.; Becker, R.; Klein, H.; Maaser, A.; Mueller, J.; Thomae, R.; Weber, M.

    1995-01-01

    For beam diagnostics aside from Faraday cups for current measurements and analysing magnets for the determination of beam composition and energy the most important tool is an emittance measurement device. With such a system the distribution of the beam particles in phase-space can be determined. This yields information not only on the position of the particles but also on their angle with respect to the beam axis. There are different kinds of emittance measurement devices using either circular holes or slits for separation of part of the beam. The second method (slit-slit measurement), though important for the determination of the rms-emittance, has the disadvantage of integrating over the y- and y'-coordinate (measurement in xx'-plane assumed). This leads to different emittance diagrams than point-point measurements, since in xx'-plane for each two corresponding points of rr'-plane there exists a connecting line. With regard to beam aberrations this makes xx'-emittances harder to interpret. In this paper the two kinds of emittance diagrams are discussed. Additionally the influence of the slit height on the xx'-emittance is considered. The analytical results are compared to experimental measurements in rr'-, rx'- and xx'-phase-space. (orig.)

  8. Beam emittance measurement from CERN thermionic guns

    International Nuclear Information System (INIS)

    Kester, O.; Rao, R.; Rinolfi, L.

    1992-01-01

    In the LEP Injector Linacs (LIL) a thermionic gun provides electron beams with different peak intensities at an energy of 80 keV. The beam emittances were estimated from the EGUN programme. Since the gun is of triode type, the main contribution to the emittance comes from the grid. The simulation programme does not model the real geometry by assuming a cylindrical symmetry, while the grid does not have such symmetry. A Gun Test Facility (GTF), allowing emittance measurements, based on the 3-gradients-method was installed. The experimental results are presented. (author) 6 refs.; 6 figs

  9. Counting efficiency for liquid scintillator systems with a single multiplier phototube

    International Nuclear Information System (INIS)

    Grau Malonda, A.; Garcia-Torano, E.

    1984-01-01

    In this paper counting efficiency as a function of a free parameter (the figure of merit) has been computed. The results are applicable to liquid scintillator systems with a single multiplier phototube. Tables of counting efficiency for 62 pure beta emitters are given for figures of merit in the range 0.25 to 50. (Author) 16 refs

  10. Internal emitter research and standard setting

    International Nuclear Information System (INIS)

    Stannard, J.N.

    1981-01-01

    The history of the use of data from internal emitter research in the derivation of safety standards is reviewed. At first, observed biological effects were correlated with body burdens or exposure levels. This direct approach is illustrated by detailed accounts of the cases of uranium and plutonium. In the 1950's, when it was decided to provide standards for over 200 isotopes, the direct approach was replaced by a system of calculations. This necessitated changes in internal emitter research programs to provide metabolic data, and the development of models such as Reference Man and the Lung and Gastrointestinal Tract models. The continuing contribution of internal emitter research to standard setting can be seen in the references quoted in the metabolic data section of the new ICRP report (ICRP Publication 30). Present trends suggest a possible return to the direct use of internal emitter effects data for obtaining risk estimates. (U.K.)

  11. Beam emittance measurements on multicusp ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Sarstedt, M.; Lee, Y.; Leung, K.N. [and others

    1995-08-01

    Multicusp ion sources are used for various applications. Presently, the implementation of this type of ion source planned for the development of an ion beam lithography machine, which will be used for the projection of sub-0.2 {mu}m patterns onto a wafer substrate. Since, for this application, a very good beam quality and a small ion energy spread are required, emittance measurements have been performed on a multicusp ion source for various source conditions. It is shown that the installation of proper capacitors between the extraction electrodes is necessary to avoid rf-pickup, which otherwise leads to a distortion of the beam emittance. The influence of the magnetic filter field on the beam emittance has been investigated, and the beam emittance of a dc filament-discharge plasma has also been compared to that of an rf-generated plasma.

  12. Beam emittance measurements on multicusp ion sources

    International Nuclear Information System (INIS)

    Sarstedt, M.; Lee, Y.; Leung, K.N.

    1995-08-01

    Multicusp ion sources are used for various applications. Presently, the implementation of this type of ion source planned for the development of an ion beam lithography machine, which will be used for the projection of sub-0.2 μm patterns onto a wafer substrate. Since, for this application, a very good beam quality and a small ion energy spread are required, emittance measurements have been performed on a multicusp ion source for various source conditions. It is shown that the installation of proper capacitors between the extraction electrodes is necessary to avoid rf-pickup, which otherwise leads to a distortion of the beam emittance. The influence of the magnetic filter field on the beam emittance has been investigated, and the beam emittance of a dc filament-discharge plasma has also been compared to that of an rf-generated plasma

  13. Self-powered detectors with thulium emitter

    International Nuclear Information System (INIS)

    Haller, P.; Klar, E.

    1978-01-01

    In addition to fission chambers, prompt-indicating self-powered (SPN) detectors are used for measuring the neutron flux density in the core of power reactors. Although current SPN detectors with a cobalt emitter give satisfactora results, detectors with other emitter materials have been analyzed and tested. The author describes the properties and decay pattern of the nuclide thulium and presents the results of measurements made while testing thulium detectors. (orig.) [de

  14. Alpha-emitters for medical therapy workshop

    International Nuclear Information System (INIS)

    Feinendegen, L.E.; McClure, J.J.

    1996-01-01

    A workshop on ''Alpha-Emitters for Medical Therapy'' was held May 30-31, 1996 in Denver Colorado to identify research goals and potential clinical needs for applying alpha-particle emitters and to provide DOE with sufficient information for future planning. The workshop was attended by 36 participants representing radiooncology, nuclear medicine, immunotherapy, radiobiology, molecular biology, biochemistry, radiopharmaceutical chemistry, dosimetry, and physics. This report provides a summary of the key points and recommendations arrived at during the conference

  15. Alpha-emitters for medical therapy workshop

    Energy Technology Data Exchange (ETDEWEB)

    Feinendegen, L.E.; McClure, J.J.

    1996-12-31

    A workshop on ``Alpha-Emitters for Medical Therapy`` was held May 30-31, 1996 in Denver Colorado to identify research goals and potential clinical needs for applying alpha-particle emitters and to provide DOE with sufficient information for future planning. The workshop was attended by 36 participants representing radiooncology, nuclear medicine, immunotherapy, radiobiology, molecular biology, biochemistry, radiopharmaceutical chemistry, dosimetry, and physics. This report provides a summary of the key points and recommendations arrived at during the conference.

  16. Multinozzle emitter arrays for ultrahigh-throughput nanoelectrospray mass spectrometry

    Science.gov (United States)

    Wang, Daojing; Mao, Pan; Wang, Hung-Ta; Yang, Peidong

    2017-10-17

    The present invention provides for a structure comprising a plurality of emitters, wherein a first nozzle of a first emitter and a second nozzle of a second emitter emit in two directions that are not or essentially not in the same direction; wherein the walls of the nozzles and the emitters form a monolithic whole. The present invention also provides for a structure comprising an emitter with a sharpened end from which the emitter emits; wherein the emitters forms a monolithic whole. The present invention also provides for a fully integrated separation of proteins and small molecules on a silicon chip before the electrospray mass spectrometry analysis.

  17. Calculation of the detection efficiency in liquid scintillators. I.- Single negatrons emitters; Calculo de la eficiencia de deteccion en liquidos centelleadores. I. Nucleidos que se desintegran por emision simple de negatrones

    Energy Technology Data Exchange (ETDEWEB)

    Grau Malonda, A.; Garcia-torano, E.

    1981-07-01

    Counting efficiency for 62 single beta emitters has been computed from the beta energy distribution, the figure of merit and the ionization quenching. Efficiency v.s. figure of merit is plotted and tabulated. (Author) 16 refs.

  18. Validation the quantification of beta emitters activity in urine by scintillation spectrometry in the liquid phase

    International Nuclear Information System (INIS)

    Sierra, I.; Hernandez, C.; Benito, P.; Lopez, C.

    2013-01-01

    In this paper the methodology used in the validation of the technique for quantifying activity of some beta emitters in urine ( 3 H, 1 4C, 3 5S, 3 2P and 9 0Sr) by scintillation spectrometry Liquid Phase (Liquid Scintillation Counting, LSC) is described in bio elimination Laboratory Service CIEMAT Radiation Dosimetry accredited since last year for carrying out assays measure radiation dose based on ISO forth above. (Author)

  19. Calculation of the detection efficiency in liquid scintillators. II. Single positron emitters

    International Nuclear Information System (INIS)

    Grau Malonda, A.; Garcia Torano, E.

    1982-01-01

    Counting efficiency as a function of the figure of merit for 30 positron emitters has been computed from the positron energy spectrum. Only the efficiency contribution of positrons has been taken into consideration. The contribution of the annihilation photons depending on the volume of the scintillator will be investigated in a near future. Efficiency vs figure of merit is plotted and tabulated. (Author) 19 refs

  20. Measurements of Thermal Emittance for Cesium Telluride Photocathodes at PITZ

    CERN Document Server

    Miltchev, V; Grabosch, H J; Han, J H; Krasilnikov, M; Oppelt, A; Petrosian, B; Staykov, L; Stephan, F

    2005-01-01

    The thermal emittance determines the lower emittance limit and its measurement is of high importance to understand the ultimate injector performance. In this contribution we present results of thermal emittance measurements under rf operation conditions for various Cs2Te cathodes and different accelerating gradients. Measurements of thermal emittance scaling with the cathode laser spot size are presented and analysed. The significance of the Schottky effect in the emittance formation process is discussed.

  1. A low-emittance lattice for SPEAR

    International Nuclear Information System (INIS)

    Safranek, J.; Wiedemann, H.

    1992-01-01

    The design and implementation of a low emittance lattice for the SPEAR storage ring including measurements of the performance of the lattice are presented (J. Safranek, Ph. D. thesis, Stanford University, 1991). The low emittance lattice is designed to optimize the performance of SPEAR as a synchrotron radiation source while keeping SPEAR hardware changes at a minimum. The horizontal emittance of the electron beam in the low emittance lattice is reduced by a factor of 4 from the previous lattice. This reduces the typical horizontal source size and divergence of the photon beams by a factor of 2 each and increases the photon beam brightness. At 3 GeV the horizontal emittance is 129 π nm rad, which makes the low emittance lattice the lowest emittance, runnning synchroton radiation source in the world in the 1.5 to 4.0 GeV energy range for the emittance scaled to 3 GeV. The measured vertical emittance was reduced to half that typically seen at SPEAR in the past. The brightness of the photon beams was further incrased by reducing β y at the insertion devices to 1.1 m and reducing the energy dispersion at the insertion devices by more than a factor of 2 on average. The horizontal despersion at the rf cavities was reduced by a factor of nearly 4 which gives much less problems with synchrobetatron resonances. The dynamic and physical apertures of the lattice are large, giving long beam lifetimes and easy injection of electrons. The measurements of the linear optics and intensity dependent phenomena gave resonable agreement with the design . The overall performance of the machine was very good. Injection rates of 10 to 20 mA/min and larger were achieved routinely, and 100 mA total current was stored. Repeated ramping of stored beam from the injection energy of 2.3 GeV to the running energy of 3.0 GeV was achieved with very little beam loss. This low emittance configuration is expected to be the operating configuration for SPEAR starting in January 1992. (orig.)

  2. A new crystal whole-body scanner for positron emitters

    International Nuclear Information System (INIS)

    Ostertag, H.; Kuebler, W.; Kubesch, R.; Lorenz, W.J.; Woerner, P.

    1980-01-01

    A multicrystal whole body scanner for positron emitters has been constructed. The annihilation quanta are measured in two opposing detector banks. Each detector bank consists of 64 NaI crystals of 1.5'' diameter x 3'' length. Directly opposing single detectors are in coincidence. The patient moves linearly between the stationary transverse detector banks. The scanning area of the system is 64 x 192 cm 2 . The spatial resolution is 2 cm at a sampling distance of 1 cm. The sensitivity is 6400 counts/s for a pure positron flood source with 1 μCi/cm 2 . The system is controlled by a microcomputer (DEC LSI-11). The scintigrams are shown on a display. Absolute activities can be calculated by mathematical comparison of consecutive emission and transmission scans. The design of the positron scanner and its capacibilities are described. Experimental and initial clinical results are presented. (author)

  3. Performance of gamma spectrometry counting system

    International Nuclear Information System (INIS)

    Yii Mei Wo; Maziah Mahmud

    2007-01-01

    Gamma spectrometry counting system widely used as tool to measure qualitative and quantitative gamma-ray emitters in a sample. Container size, sample to detector distance, sample volume are well known factors that affecting the quality of measurement. However, factor such as the age of the system was not been reported. Therefore, the objective of this study is to find out how the age factor affecting the quality of the measurement. From this study, it is found that when the age of the system increased, the system tends to have higher lower limit of detection and poorer linearity showing that age factor do affecting the quality of measurement. (Author)

  4. Morphological Effects of HA on the Cell Compatibility of Electrospun HA/PLGA Composite Nanofiber Scaffolds

    Directory of Open Access Journals (Sweden)

    Adnan Haider

    2014-01-01

    Full Text Available Tissue engineering is faced with an uphill challenge to design a platform with appropriate topography and suitable surface chemistry, which could encourage desired cellular activities and guide bone tissue regeneration. To develop such scaffolds, composite nanofiber scaffolds of nHA and sHA with PLGA were fabricated using electrospinning technique. nHA was synthesized using precipitation method, whereas sHA was purchased. The nHA and sHA were suspended in PLGA solution separately and electrospun at optimized electrospinning parameters. The composite nanofiber scaffolds were characterized by FE-SEM, EDX analysis, TEM, XRD analysis, FTIR, and X-ray photoelectron. The potential of the HA/PLGA composite nanofiber as bone scaffolds in terms of their bioactivity and biocompatibility was assessed by culturing the osteoblastic cells onto the composite nanofiber scaffolds. The results from in vitro studies revealed that the nHA/PLGA composite nanofiber scaffolds showed higher cellular adhesion, proliferation, and enhanced osteogenesis performance, along with increased Ca+2 ions release compared to the sHA/PLGA composite nanofiber scaffolds and pristine PLGA nanofiber scaffold. The results show that the structural dependent property of HA might affect its potential as bone scaffold and implantable materials in regenerative medicine and clinical tissue engineering.

  5. Sterilisation effect study on granular hydroxyapatite (HA)

    International Nuclear Information System (INIS)

    Saidu, M.F.; Mashita, M.; Khadijah, K.; Fazan, F.; Khalid, K.A.

    2004-01-01

    Hydroxyapatite (HA) is a calcium phosphate bio ceramic that has been shown by many authors to be biocompatible with bioactive properties. It is widely accepted as the best synthetic material available for surgical use as a bone graft substitute. HA granules produced by Amerce-SIRIM from local materials underwent 5 types of sterilisation techniques with different ageing periods. Samples were tested for chemical and phase composition and microbial contamination before and after being sterilised. From the microbiological tests done, none of the unsterilised positive control yielded a positive culture. Results from X-Ray diffraction studies found that all the sterilisation techniques did not chemically degrade or structurally change the HA granules significantly. (Author)

  6. Generalized superradiant assembly for nanophotonic thermal emitters

    Science.gov (United States)

    Mallawaarachchi, Sudaraka; Gunapala, Sarath D.; Stockman, Mark I.; Premaratne, Malin

    2018-03-01

    Superradiance explains the collective enhancement of emission, observed when nanophotonic emitters are arranged within subwavelength proximity and perfect symmetry. Thermal superradiant emitter assemblies with variable photon far-field coupling rates are known to be capable of outperforming their conventional, nonsuperradiant counterparts. However, due to the inability to account for assemblies comprising emitters with various materials and dimensional configurations, existing thermal superradiant models are inadequate and incongruent. In this paper, a generalized thermal superradiant assembly for nanophotonic emitters is developed from first principles. Spectral analysis shows that not only does the proposed model outperform existing models in power delivery, but also portrays unforeseen and startling characteristics during emission. These electromagnetically induced transparency like (EIT-like) and superscattering-like characteristics are reported here for a superradiant assembly, and the effects escalate as the emitters become increasingly disparate. The fact that the EIT-like characteristics are in close agreement with a recent experimental observation involving the superradiant decay of qubits strongly bolsters the validity of the proposed model.

  7. Electron emitter pulsed-type cylindrical IEC

    International Nuclear Information System (INIS)

    Miley, G.H.; Gu, Y.; Stubbers, R.; Zich, R.; Anderl, R.; Hartwell, J.

    1997-01-01

    A cylindrical version of the single grid Inertial Electrostatic Confinement (IEC) device (termed the C-device) has been developed for use as a 2.5-MeV D-D fusion neutron source for neutron activation analysis. The C-device employs a hollow-tube type cathode with similar anodes backed up by ''reflector'' dishes. The resulting discharge differs from a conventional hollow cathode discharge, by creating an explicit ion beam which is ''pinched'' in the cathode region. Resulting fusion reactions generate ∼10 6 neutron/s. A pulsed version is under development for applications requiring higher fluxes. Several pulsing techniques are under study, including an electron emitter (e-emitter) assisted discharge in a thorated tungsten wire emitter located behind a slotted area in the reflector dishes. Pulsing is initiated after establishing a low power steady-state discharge by pulsing the e-emitter current using a capacitor switch type circuit. The resulting electron jet, coupled with the discharge by the biased slot array, creates a strong pulse in the pinched ion beam. The pulse length/repetition rate are controlled by the e-emitter pulse circuit. Typical parameters in present studies are ∼30micros, 10Hz and 1-amp ion current. Corresponding neutron measurements are an In-foil type activation counter for time averaged rates. Results for a wide variety of operating conditions are presented

  8. Diamond-based single-photon emitters

    International Nuclear Information System (INIS)

    Aharonovich, I; Castelletto, S; Simpson, D A; Su, C-H; Greentree, A D; Prawer, S

    2011-01-01

    The exploitation of emerging quantum technologies requires efficient fabrication of key building blocks. Sources of single photons are extremely important across many applications as they can serve as vectors for quantum information-thereby allowing long-range (perhaps even global-scale) quantum states to be made and manipulated for tasks such as quantum communication or distributed quantum computation. At the single-emitter level, quantum sources also afford new possibilities in terms of nanoscopy and bio-marking. Color centers in diamond are prominent candidates to generate and manipulate quantum states of light, as they are a photostable solid-state source of single photons at room temperature. In this review, we discuss the state of the art of diamond-based single-photon emitters and highlight their fabrication methodologies. We present the experimental techniques used to characterize the quantum emitters and discuss their photophysical properties. We outline a number of applications including quantum key distribution, bio-marking and sub-diffraction imaging, where diamond-based single emitters are playing a crucial role. We conclude with a discussion of the main challenges and perspectives for employing diamond emitters in quantum information processing.

  9. BEAM EMITTANCE MEASUREMENT TOOL FOR CEBAF OPERATIONS

    International Nuclear Information System (INIS)

    Chevtsov, Pavel; Tiefenback, Michael

    2008-01-01

    A new software tool was created at Jefferson Lab to measure the emittance of the CEBAF electron beams. The tool consists of device control and data analysis applications. The device control application handles the work of wire scanners and writes their measurement results as well as the information about accelerator settings during these measurements into wire scanner data files. The data analysis application reads these files and calculates the beam emittance on the basis of a wire scanner data processing model. Both applications are computer platform independent but are mostly used on LINUX PCs recently installed in the accelerator control room. The new tool significantly simplifies beam emittance measurement procedures for accelerator operations and contributes to a very high availability of the CEBAF machine for the nuclear physics program at Jefferson Lab.

  10. Solid-state single-photon emitters

    Science.gov (United States)

    Aharonovich, Igor; Englund, Dirk; Toth, Milos

    2016-10-01

    Single-photon emitters play an important role in many leading quantum technologies. There is still no 'ideal' on-demand single-photon emitter, but a plethora of promising material systems have been developed, and several have transitioned from proof-of-concept to engineering efforts with steadily improving performance. Here, we review recent progress in the race towards true single-photon emitters required for a range of quantum information processing applications. We focus on solid-state systems including quantum dots, defects in solids, two-dimensional hosts and carbon nanotubes, as these are well positioned to benefit from recent breakthroughs in nanofabrication and materials growth techniques. We consider the main challenges and key advantages of each platform, with a focus on scalable on-chip integration and fabrication of identical sources on photonic circuits.

  11. MD2065: Emittance exchange with linear coupling

    CERN Document Server

    Carver, Lee Robert; Persson, Tobias Hakan Bjorn; Amorim, David; Levens, Tom; Pesah, Arthur Chalom; CERN. Geneva. ATS Department

    2018-01-01

    In order to better understand the luminosity imbalance between ATLAS and CMS that was observed in 2016, it was proposed to perform a test whereby the horizontal and vertical emittances are exchanged by crossing the tunes in the presence of linear coupling. The luminosity before and after the exchange could be compared to see if the imbalance stems purely from the uneven emittances or if there is an additional mechanism in play. However, due to limited machine availability only tests at injection were able to performed.

  12. Minimum emittance of three-bend achromats

    International Nuclear Information System (INIS)

    Li Xiaoyu; Xu Gang

    2012-01-01

    The calculation of the minimum emittance of three-bend achromats (TBAs) made by Mathematical software can ignore the actual magnets lattice in the matching condition of dispersion function in phase space. The minimum scaling factors of two kinds of widely used TBA lattices are obtained. Then the relationship between the lengths and the radii of the three dipoles in TBA is obtained and so is the minimum scaling factor, when the TBA lattice achieves its minimum emittance. The procedure of analysis and the results can be widely used in achromats lattices, because the calculation is not restricted by the actual lattice. (authors)

  13. Quadrupole Transfer Function for Emittance Measurement

    CERN Document Server

    Cameron, Peter; Jansson, Andreas; Tan, Cheng-Yang

    2008-01-01

    Historically the use of the quadrupole moment measurement has been impeded by the requirement for large dynamic range, as well as measurement sensitivity to beam position. We investigate the use of the transfer function technique [1-3] in combination with the sensitivity and 160dB revolution line rejection of the direct diode detection analog front end [4] to open the possibility of an emittance diagnostic that may be implemented without operational complication, quasi- parasitic to the operation of existing tune measurement systems. Such a diagnostic would be particularly useful as an emittance monitor during acceleration ramp development in machines like RHIC and the LHC.

  14. Studies of emittance growth in the ATF

    International Nuclear Information System (INIS)

    Zimmermann, F.

    1997-03-01

    Several different mechanisms of emittance growth in the Accelerator Test Facility (ATF) at KEK are investigated: the author calculates rise times of the fast beam-ion instability for the damping ring (DR), and discusses the emittance growth caused by coherent synchrotron radiation in the beam-transport line (BT), the effect of quadrupole wake fields in the injector linac, and, finally, a single-bunch head-tail ion effect that can occur in both the DR and the BT. A first attempt to measure the quadrupole wake on the real machine is also reported

  15. Determining random counts in liquid scintillation counting

    International Nuclear Information System (INIS)

    Horrocks, D.L.

    1979-01-01

    During measurements involving coincidence counting techniques, errors can arise due to the detection of chance or random coincidences in the multiple detectors used. A method and the electronic circuits necessary are here described for eliminating this source of error in liquid scintillation detectors used in coincidence counting. (UK)

  16. A low emittance configuration for spear

    International Nuclear Information System (INIS)

    Blumberg, L.N.; Cerino, J.; Harris, J.; Hettel, R.; Hofmann, A.; Liu, R.Z.; Stego, R.; Wiedemann, H.; Winick, H.

    1985-01-01

    The quality of synchrotron radiation beams from SPEAR, in particular the brilliance of undulator radiation, can be improved significantly by reducing the emittance of the stored electron beam. A reduction of the horizontal emittance by a factor of 3.5 to a value of 130 nanometer-radians (nm-r) at 3 GeV has been achieved by using stronger focussing, mainly in the horizontal plane. The low emittance configuration also reduces the dispersion and vertical beta functions in the straight sections, making them more suitable for wigglers. The higher betatron tunes lead to a larger phase advance between the two kickers, which has to be corrected during injection by shunting current from some quadrupoles. The configuration was optimized within SPEAR hardware limitations and tested for dynamic aperture with the tracking program PATRICIA. After implementation of this scheme, beam was successfully injected and accumulated. The measured emittance of the stored beam was in agreement with calculations. Presently the configuration is being made operational

  17. Simple-to-prepare multipoint field emitter

    Science.gov (United States)

    Sominskii, G. G.; Taradaev, E. P.; Tumareva, T. A.; Mishin, M. V.; Kornishin, S. Yu.

    2015-07-01

    We investigate multitip field emitters prepared by electroerosion treatment of the surface of molybdenum samples. Their characteristics are determined for operation with a protecting activated fullerene coating. Our experiments indicate that such cathodes are promising for high-voltage electron devices operating in technical vacuum.

  18. Emittance measuring system on the UNILAC

    International Nuclear Information System (INIS)

    Ehrich, A.; Glatz, J.; Strahl, P.

    A description is given of one of the beam emittance measuring systems designed for the UNILAC at GSI. The measuring system mechanics and the detector system are detailed, and the associated electronics are discussed. Computer programming and data processing and evaluation are described

  19. Emittance growth rates for displaced beams

    International Nuclear Information System (INIS)

    Anderson, O.A.

    1993-05-01

    Emittance growth rates have been previously analyzed for nonuniform beams in linear channels and for initially uniform mismatched beams in nonlinear channels. These studies were for centered beams. Additional emittance growth can arise in cases where the beam is initially displaced. The purpose of this study is to obtain growth rates for displaced beams. This work differs from studies involving random displacement of electrodes. Our analysis assumes instead that the focusing system is perfectly aligned but that the beam is initially displaced with respect to the equilibrium axis. If the focusing force is slightly nonlinear, we find a gradual transfer of the potential energy of beam displacement into kinetic energy associated with emittance growth. We present explicit results for the emittance growth distance as a function of the nonlinearity of the channel. These results will have practical importance for designers of accelerators and transport systems when setting realistic tolerances for initial beam alignment. These tolerances will depend on the nonlinearity and the length of the system

  20. Aluminum oxide film thickness and emittance

    International Nuclear Information System (INIS)

    Thomas, J.K.; Ondrejcin, R.S.

    1991-11-01

    Aluminum reactor components which are not actively cooled could be subjected to high temperatures due to gamma heating after the core coolant level dropped during the ECS phase of a hypothetical LOCA event. Radiative heat transfer is the dominant heat transfer process in this scenario and therefore the emittance of these components is of interest. Of particular interest are the safety rod thimbles and Mark 60B blanket assemblies; for the K Reactor, these components have been exposed to low temperature (< 55 degrees C) moderator for about a year. The average moderator temperature was assumed to be 30 degrees C. The Al oxide film thickness at this temperature, after one year of exposure, is predicted to be 6.4 μm ± 10%; insensitive to exposure time. Dehydration of the film during the gamma heating accident would result in a film thickness of 6.0 μm ± 11%. Total hemispherical emittance is predicted to be 0.69 at 96 degrees C, decreasing to 0.45 at 600 degrees C. Some phenomena which would tend to yield thicker oxide films in the reactor environment relative to those obtained under experimental conditions were neglected and the predicted film thickness values are therefore conservative. The emittance values predicted for a given film thickness are also conservative. The conservativisms inherent in the predicted emittance are particularly relevant for uncertainty analysis of temperatures generated using these values

  1. Low Cost Constant – Head Drip Irrigation Emitter for Climate ...

    African Journals Online (AJOL)

    Low Cost Constant – Head Drip Irrigation Emitter for Climate Change Adaptation in Nigeria: Engineering Design and Calibration. ... The drip system comprises of abarrel, sub-main line, lateral lines, tubes and emitters, it can irrigate140 crop ...

  2. Test results on two thermionic converters with cermet emitters

    International Nuclear Information System (INIS)

    Saunders, M.; Danielson, L.; Huffman, F.

    1983-01-01

    An emitter made of a directionally solidified Mo-Al 2 O 3 , Cr 2 O 3 eutectic was provided by Eindhoven University of Technology in Eindhoven, The Netherlands. Although the high temperature braze cycle used in bonding this electrode to the emitter substrate destroyed its characteristic needle microstructure, the converter gave good performance. Apparently, chemical species evaporated from the emitter onto the collector provided a low collector work function. The resulting low barrier indices suggest that this surface is a promising emitter

  3. Clean Hands Count

    Medline Plus

    Full Text Available ... Like this video? Sign in to make your opinion count. Sign in 131 2 Don't like this video? Sign in to make your opinion count. Sign in 3 Loading... Loading... Transcript The ...

  4. The Big Pumpkin Count.

    Science.gov (United States)

    Coplestone-Loomis, Lenny

    1981-01-01

    Pumpkin seeds are counted after students convert pumpkins to jack-o-lanterns. Among the activities involved, pupils learn to count by 10s, make estimates, and to construct a visual representation of 1,000. (MP)

  5. Preliminary studies for the determination of alpha emitters using the gross alpha coprecipitation methods

    International Nuclear Information System (INIS)

    Suarez-Navarro, J. A.; Pujol, L.; Suarez, J. A.; Pablo, M. A. de

    2003-01-01

    The radiological quality of drinking water in Spain is regulated by Nuclear Security Guideline No, 7.7 (Rev.1) of the Nuclear Security Council (NSC). this guideline establishes the protocol to follow when the radiological level exceeds 0,1 Bq.l''1. When this level is passed, the responsible alpha emitter must be identified; ''210 Po, ''226Ra, ''230Th, ''239Pu, ''224Ra, ''234 U and ''138 U. Activity due to these isotopes is usually determined using alpha spectrometry with semiconductor detectors. This method allows the activity of the alpha emitters to be determined with a good sensitivity. however, it requires long radiochemical isolations and long counting times, so the method is not suitable for rough estimate radiological analysis. In this preliminary work, we present the conditioning of the sample-precipitate that is essential for further radiochemical isolations. (Author) 9 refs

  6. Monte Carlo simulation of the spectral response of beta-particle emitters in LSC systems

    International Nuclear Information System (INIS)

    Ortiz, F.; Los Arcos, J.M.; Grau, A.; Rodriguez, L.

    1992-01-01

    This paper presents a new method to evaluate the counting efficiency and the effective spectra at the output of any dynodic stage, for any pure beta-particle emitter, measured in a liquid scintillation counting system with two photomultipliers working in sum-coincidence mode. The process is carried out by a Monte Carlo simulation procedure that gives the electron distribution, and consequently the counting efficiency, at any dynode, in response to the beta particles emitted, as a function of the figure of merit of the system and the dynodic gains. The spectral outputs for 3 H and 14 C have been computed and compared with experimental data obtained with two sets of quenched radioactive standards of these nuclides. (orig.)

  7. High-Precision Half-life Measurements for the Superallowed β+ Emitter 14O

    Science.gov (United States)

    Laffoley, A. T.; Svensson, C. E.; Andreoiu, C.; Austin, R. A. E.; Ball, G. C.; Blank, B.; Bouzomita, H.; Cross, D. S.; Diaz Varela, A.; Dunlop, R.; Finlay, P.; Garnsworthy, A. B.; Garrett, P. E.; Giovinazzo, J.; Grinyer, G. F.; Hackman, G.; Hadinia, B.; Jamieson, D. S.; Ketelhut, S.; Leach, K. G.; Leslie, J. R.; Tardiff, E. R.; Thomas, J. C.; Unsworth, C.

    2014-03-01

    The half-life of 14O, a superallowed Fermi β+ emitter, has been determined via simultaneous γ and β counting experiments at TRIUMF's Isotope Separator and Accelerator facility. Following the implantation of 14O samples at the center of the 8π spectrometer, a γ counting measurement was performed by detecting the 2313 keV γ-rays emitted from the first excited state of the daughter 14N using 20 high-purity germanium (HPGe) detectors. A simultaneous β counting experiment was performed using a fast plastic scintillator positioned directly behind the implantation site. The results, T½(γ) = 70:632 ± 0:094 s and T½(β) = 70:610 ± 0:030 s, are consistent with one another and, together with eight previous measurements, establish a new average for the 14O half-life of T½ = 70:619 ± 0:011 s with a reduced χ2 of 0.99.

  8. Radiation counting statistics

    Energy Technology Data Exchange (ETDEWEB)

    Suh, M. Y.; Jee, K. Y.; Park, K. K.; Park, Y. J.; Kim, W. H

    1999-08-01

    This report is intended to describe the statistical methods necessary to design and conduct radiation counting experiments and evaluate the data from the experiment. The methods are described for the evaluation of the stability of a counting system and the estimation of the precision of counting data by application of probability distribution models. The methods for the determination of the uncertainty of the results calculated from the number of counts, as well as various statistical methods for the reduction of counting error are also described. (Author). 11 refs., 8 tabs., 8 figs.

  9. Radiation counting statistics

    Energy Technology Data Exchange (ETDEWEB)

    Suh, M. Y.; Jee, K. Y.; Park, K. K. [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-08-01

    This report is intended to describe the statistical methods necessary to design and conduct radiation counting experiments and evaluate the data from the experiments. The methods are described for the evaluation of the stability of a counting system and the estimation of the precision of counting data by application of probability distribution models. The methods for the determination of the uncertainty of the results calculated from the number of counts, as well as various statistical methods for the reduction of counting error are also described. 11 refs., 6 figs., 8 tabs. (Author)

  10. Radiation counting statistics

    International Nuclear Information System (INIS)

    Suh, M. Y.; Jee, K. Y.; Park, K. K.; Park, Y. J.; Kim, W. H.

    1999-08-01

    This report is intended to describe the statistical methods necessary to design and conduct radiation counting experiments and evaluate the data from the experiment. The methods are described for the evaluation of the stability of a counting system and the estimation of the precision of counting data by application of probability distribution models. The methods for the determination of the uncertainty of the results calculated from the number of counts, as well as various statistical methods for the reduction of counting error are also described. (Author). 11 refs., 8 tabs., 8 figs

  11. Effect of humic acid (HA) on sulfonamide sorption by biochars

    International Nuclear Information System (INIS)

    Lian, Fei; Sun, Binbin; Chen, Xi; Zhu, Lingyan; Liu, Zhongqi; Xing, Baoshan

    2015-01-01

    Effect of quantity and fractionation of loaded humic acid (HA) on biochar sorption for sulfonamides was investigated. The HA was applied in two different modes, i.e. pre-coating and co-introduction with sorbate. In pre-coating mode, the polar fractions of HA tended to interact with low-temperature biochars via H-bonding, while the hydrophobic fractions were likely to be adsorbed by high-temperature biochars through hydrophobic and π-π interactions, leading to different composition and structure of the HA adlayers. The influences of HA fractionation on biochar sorption for sulfonamides varied significantly, depending on the nature of interaction between HA fraction and sorbate. Meanwhile, co-introduction of HA with sulfonamides revealed that the effect of HA on sulfonamide sorption was also dependent on HA concentration. These findings suggest that the amount and fractionation of adsorbed HA are tailored by the surface properties of underlying biochars, which differently affect the sorption for organic contaminants. - Highlights: • Effect of quantity and fractionation of coated HA on sorption of sulfonamides by BC was studied. • Fractionation of coated HA is tailored by surface properties of BC. • Roles of HA in BC sorption depend on interaction between HA adlayer and sorbate. • Roles of HA in sulfonamide sorption by BC also depend on HA aqueous concentration. - The quantity and fractionation of adsorbed HA play a major role in sulfonamide sorption by biochars

  12. 2-D emittance equation with acceleration and compression

    International Nuclear Information System (INIS)

    Hahn, K.D.; Smith, L.

    1988-10-01

    Since both acceleration and compression are required for an Inertial Fusion Driver, the understanding of their effect on the beam quality, emittance, is important. This report attempts to generalize the usual emittance formula for the drifting beam to include these effects. The derivation of the 2-D emittance equation is carried out and a comparison with the particle code results is given. The 2-D emittance at a given axial location is reasonable to consider for a long beam, particularly with velocity tilt; transverse emittance averaged over the entire bunch is not a useful quantity. 6 refs., 2 figs., 1 tab

  13. Small horizontal emittance in the TESLA damping ring

    International Nuclear Information System (INIS)

    Decking, W.

    2001-01-01

    The present TESLA damping ring is designed for a normalized horizontal emittance of 8x10 -6 m. γ-γ collisions at the TESLA linear collider will benefit from a further decrease of the horizontal emittance. This paper reviews the processes which limit the horizontal emittance in the damping ring. Preliminary estimates on the smallest horizontal emittance for the present TESLA damping ring design as well as an ultimate limit of the emittance reachable with the TESLA damping ring concept will be given

  14. Development of Emittance Analysis Software for Ion Beam Characterization

    International Nuclear Information System (INIS)

    Padilla, M.J.; Liu, Yuan

    2007-01-01

    Transverse beam emittance is a crucial property of charged particle beams that describes their angular and spatial spread. It is a figure of merit frequently used to determine the quality of ion beams, the compatibility of an ion beam with a given beam transport system, and the ability to suppress neighboring isotopes at on-line mass separator facilities. Generally, a high-quality beam is characterized by a small emittance. In order to determine and improve the quality of ion beams used at the Holifield Radioactive Ion Beam Facility (HRIBF) for nuclear physics and nuclear astrophysics research, the emittances of the ion beams are measured at the off-line Ion Source Test Facilities. In this project, emittance analysis software was developed to perform various data processing tasks for noise reduction, to evaluate root-mean-square emittance, Twiss parameters, and area emittance of different beam fractions. The software also provides 2D and 3D graphical views of the emittance data, beam profiles, emittance contours, and RMS. Noise exclusion is essential for accurate determination of beam emittance values. A Self-Consistent, Unbiased Elliptical Exclusion (SCUBEEx) method is employed. Numerical data analysis techniques such as interpolation and nonlinear fitting are also incorporated into the software. The software will provide a simplified, fast tool for comprehensive emittance analysis. The main functions of the software package have been completed. In preliminary tests with experimental emittance data, the analysis results using the software were shown to be accurate

  15. DEVELOPMENT OF EMITTANCE ANALYSIS SOFTWARE FOR ION BEAM CHARACTERIZATION

    Energy Technology Data Exchange (ETDEWEB)

    Padilla, M. J.; Liu, Y.

    2007-01-01

    Transverse beam emittance is a crucial property of charged particle beams that describes their angular and spatial spread. It is a fi gure of merit frequently used to determine the quality of ion beams, the compatibility of an ion beam with a given beam transport system, and the ability to suppress neighboring isotopes at on-line mass separator facilities. Generally a high quality beam is characterized by a small emittance. In order to determine and improve the quality of ion beams used at the Holifi eld Radioactive Ion beam Facility (HRIBF) for nuclear physics and nuclear astrophysics research, the emittances of the ion beams are measured at the off-line Ion Source Test Facilities. In this project, emittance analysis software was developed to perform various data processing tasks for noise reduction, to evaluate root-mean-square emittance, Twiss parameters, and area emittance of different beam fractions. The software also provides 2D and 3D graphical views of the emittance data, beam profi les, emittance contours, and RMS. Noise exclusion is essential for accurate determination of beam emittance values. A Self-Consistent, Unbiased Elliptical Exclusion (SCUBEEx) method is employed. Numerical data analysis techniques such as interpolation and nonlinear fi tting are also incorporated into the software. The software will provide a simplifi ed, fast tool for comprehensive emittance analysis. The main functions of the software package have been completed. In preliminary tests with experimental emittance data, the analysis results using the software were shown to be accurate.

  16. Ghost signals in Allison emittance scanners

    International Nuclear Information System (INIS)

    Stockli, Martin P.; Leitner, M.; Moehs, D.P.; Keller, R.; Welton, R.F.

    2004-01-01

    For over 20 years, Allison scanners have been used to measure emittances of low-energy ion beams. We show that scanning large trajectory angles produces ghost signals caused by the sampled beamlet impacting on an electric deflection plate. The ghost signal strength is proportional to the amount of beam entering the scanner. Depending on the ions, and their velocity, the ghost signals can have the opposite or the same polarity as the main beam signals. The ghost signals cause significant errors in the emittance estimates because they appear at large trajectory angles. These ghost signals often go undetected because they partly overlap with the real signals, are mostly below the 1% level, and often hide in the noise. A simple deflection plate modification is shown to reduce the ghost signal strength by over 99%

  17. Computing Eigen-Emittances from Tracking Data

    Energy Technology Data Exchange (ETDEWEB)

    Alexahin, Y. [Fermilab

    2014-09-18

    In a strongly nonlinear system the particle distribution in the phase space may develop long tails which contribution to the covariance (sigma) matrix should be suppressed for a correct estimate of the beam emittance. A method is offered based on Gaussian approximation of the original particle distribution in the phase space (Klimontovich distribution) which leads to an equation for the sigma matrix which provides efficient suppression of the tails and cannot be obtained by introducing weights. This equation is easily solved by iterations in the multi-dimensional case. It is also shown how the eigen-emittances and coupled optics functions can be retrieved from the sigma matrix in a strongly coupled system. Finally, the developed algorithm is applied to 6D ionization cooling of muons in HFOFO channel.

  18. Reducing longitudinal emittance growth in RFQ accelerators

    International Nuclear Information System (INIS)

    Koscielniak, S.

    1994-08-01

    Bunching and capture of a monochromatic beam into an rf bucket inevitably lead to substantial emittance growth through the mechanisms of filamentation and non-adiabatic variation of parameters. We describe a three step strategy for minimizing this growth, based on a clear understanding of the non-linear beam dynamics, and apply to acceleration of heavy ions with Z/A = 1/60 (and initial kinetic energy 60 keV/u) in a radio frequency quadrupole (RFQ) operating at 25 MHz. We also describe a scheme, to further reduce the emittance, based upon the use of an external RFQ-type prebuncher before the main accelerator. The external unit permits the bunching voltage to be reduced, to inject into a moving bucket, and to reduce the structure length. (author). 7 refs., 6 figs

  19. Emittance growth in coast in the SPS

    CERN Document Server

    Alekou, A; Bartosik, H; Calaga, R

    2017-01-01

    The CERN SPS will be used as a test-bed for the LHCprototype crab-cavities, which will be installed and testedin the SPS in 2018. As the time available for experimen-tal beam dynamics studies with the crab cavities installedin the machine will be limited, a very good preparation isrequired in advance. One of the main concerns is the in-duced emittance growth, driven by phase jitter in the crabcavities. In this respect, several machine development (MD)studies were performed during the past years to quantifyand characterize the emittance evolution of proton beamsin coast in the SPS. In these proceedings, the experimentalobservations from past years are summarized and the MDstudies from 2016 are presented. Finally, a proposal for anexperimental program for 2017 is discussed.

  20. Mesoscopic quantum emitters coupled to plasmonic nanostructures

    DEFF Research Database (Denmark)

    Andersen, Mads Lykke

    for the spontaneous emission of mesoscopic quantum emitters is developed. The light-matter interaction is in this model modied beyond the dipole expectancy and found to both suppress and enhance the coupling to plasmonic modes in excellent agreement with our measurements. We demonstrate that this mesoscopic effect......This thesis reports research on quantum dots coupled to dielectric and plasmonic nano-structures by way of nano-structure fabrication, optical measurements, and theoretical modeling. To study light-matter interaction, plasmonic gap waveguides with nanometer dimensions as well as samples for studies...... to allow for e- cient plasmon-based single-photon sources. Theoretical studies of coupling and propagation properties of plasmonic waveguides reveal that a high-refractive index of the medium surrounding the emitter, e.g. nGaAs = 3.5, limits the realizability of ecient plasmon-based single-photon sources...

  1. Ghost Signals In Allison Emittance Scanners

    International Nuclear Information System (INIS)

    Stockli, Martin P.; Leitner, M.; Keller, R.; Moehs, D.P.; Welton, R. F.

    2005-01-01

    For over 20 years, Allison scanners have been used to measure emittances of low-energy ion beams. We show that scanning large trajectory angles produces ghost signals caused by the sampled beamlet impacting on an electric deflection plate. The ghost signal strength is proportional to the amount of beam entering the scanner. Depending on the ions, and their velocity, the ghost signals can have the opposite or the same polarity as the main beam signals. The ghost signals cause significant errors in the emittance estimates because they appear at large trajectory angles. These ghost signals often go undetected because they partly overlap with the real signals, are mostly below the 1% level, and often hide in the noise. A simple deflection plate modification is shown to reduce the ghost signal strength by over 99%

  2. Photonic Crystal Emitters for Thermophotovoltaic Energy Conversion

    International Nuclear Information System (INIS)

    Stelmakh, Veronika; Chan, Walker R; Joannopoulos, John D; Celanovic, Ivan; Ghebrebrhan, Michael; Soljacic, Marin

    2015-01-01

    This paper reports the design, fabrication, and characterization of 2D photonic crystal (PhC) thermal emitters for a millimeter-scale hydrocarbon TPV microgenerator as a possible replacement for batteries in portable microelectronics, robotics, etc. In our TPV system, combustion heats a PhC emitter to incandescence and the resulting radiation is converted by a low-bandgap TPV cell. The PhC tailors the photonic density of states to produce spectrally confined thermal emission that matches the bandgap of the TPV cell, enabling high heat-to-electricity conversion efficiency. The work builds on a previously developed fabrication process to produce a square array of cylindrical cavities in a metal substrate. We will present ongoing incremental improvements in the optical and thermo-mechanical properties, the fabrication process, and the system integration, as recently combined with fabrication using novel materials, such as sputtered coatings, to enable a monolithic system. (paper)

  3. Characterization of New PEEK/HA Composites with 3D HA Network Fabricated by Extrusion Freeforming

    Directory of Open Access Journals (Sweden)

    Mohammad Vaezi

    2016-05-01

    Full Text Available Addition of bioactive materials such as calcium phosphates or Bioglass, and incorporation of porosity into polyetheretherketone (PEEK has been identified as an effective approach to improve bone-implant interfaces and osseointegration of PEEK-based devices. In this paper, a novel production technique based on the extrusion freeforming method is proposed that yields a bioactive PEEK/hydroxyapatite (PEEK/HA composite with a unique configuration in which the bioactive phase (i.e., HA distribution is computer-controlled within a PEEK matrix. The 100% interconnectivity of the HA network in the biocomposite confers an advantage over alternative forms of other microstructural configurations. Moreover, the technique can be employed to produce porous PEEK structures with controlled pore size and distribution, facilitating greater cellular infiltration and biological integration of PEEK composites within patient tissue. The results of unconfined, uniaxial compressive tests on these new PEEK/HA biocomposites with 40% HA under both static and cyclic mode were promising, showing the composites possess yield and compressive strength within the range of human cortical bone suitable for load bearing applications. In addition, preliminary evidence supporting initial biological safety of the new technique developed is demonstrated in this paper. Sufficient cell attachment, sustained viability in contact with the sample over a seven-day period, evidence of cell bridging and matrix deposition all confirmed excellent biocompatibility.

  4. Characterization of New PEEK/HA Composites with 3D HA Network Fabricated by Extrusion Freeforming.

    Science.gov (United States)

    Vaezi, Mohammad; Black, Cameron; Gibbs, David M R; Oreffo, Richard O C; Brady, Mark; Moshrefi-Torbati, Mohamed; Yang, Shoufeng

    2016-05-26

    Addition of bioactive materials such as calcium phosphates or Bioglass, and incorporation of porosity into polyetheretherketone (PEEK) has been identified as an effective approach to improve bone-implant interfaces and osseointegration of PEEK-based devices. In this paper, a novel production technique based on the extrusion freeforming method is proposed that yields a bioactive PEEK/hydroxyapatite (PEEK/HA) composite with a unique configuration in which the bioactive phase (i.e., HA) distribution is computer-controlled within a PEEK matrix. The 100% interconnectivity of the HA network in the biocomposite confers an advantage over alternative forms of other microstructural configurations. Moreover, the technique can be employed to produce porous PEEK structures with controlled pore size and distribution, facilitating greater cellular infiltration and biological integration of PEEK composites within patient tissue. The results of unconfined, uniaxial compressive tests on these new PEEK/HA biocomposites with 40% HA under both static and cyclic mode were promising, showing the composites possess yield and compressive strength within the range of human cortical bone suitable for load bearing applications. In addition, preliminary evidence supporting initial biological safety of the new technique developed is demonstrated in this paper. Sufficient cell attachment, sustained viability in contact with the sample over a seven-day period, evidence of cell bridging and matrix deposition all confirmed excellent biocompatibility.

  5. Standardization of Ga-68 by coincidence measurements, liquid scintillation counting and 4πγ counting.

    Science.gov (United States)

    Roteta, Miguel; Peyres, Virginia; Rodríguez Barquero, Leonor; García-Toraño, Eduardo; Arenillas, Pablo; Balpardo, Christian; Rodrígues, Darío; Llovera, Roberto

    2012-09-01

    The radionuclide (68)Ga is one of the few positron emitters that can be prepared in-house without the use of a cyclotron. It disintegrates to the ground state of (68)Zn partially by positron emission (89.1%) with a maximum energy of 1899.1 keV, and partially by electron capture (10.9%). This nuclide has been standardized in the frame of a cooperation project between the Radionuclide Metrology laboratories from CIEMAT (Spain) and CNEA (Argentina). Measurements involved several techniques: 4πβ-γ coincidences, integral gamma counting and Liquid Scintillation Counting using the triple to double coincidence ratio and the CIEMAT/NIST methods. Given the short half-life of the radionuclide assayed, a direct comparison between results from both laboratories was excluded and a comparison of experimental efficiencies of similar NaI detectors was used instead. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. Complementary methods of transverse emittance measurement

    Energy Technology Data Exchange (ETDEWEB)

    Zagel, James; Hu, Martin; Jansson, Andreas; Thurman-Keup, Randy; Yan, Ming-Jen; /Fermilab

    2008-05-01

    Several complementary transverse emittance monitors have been developed and used at the Fermilab accelerator complex. These include Ionization profile Monitors (IPM), Flying Wires, Schottky detectors and a Synchrotron Light Monitor (Synchlite). Mechanical scrapers have also been used for calibration purposes. This paper describes the various measurement devices by examining their basic features, calibration requirements, systematic uncertainties, and applications to collider operation. A comparison of results from different kinds of measurements is also presented.

  7. Modular low-voltage electron emitters

    International Nuclear Information System (INIS)

    Berejka, Anthony J.

    2005-01-01

    Modular, low-voltage electron emitters simplify electron beam (EB) technology for many industrial uses and for research and development. Modular electron emitters are produced in quantity as sealed systems that are evacuated at the factory, eliminating the need for vacuum pumps at the point of use. A plug-out-plug-in method of replacement facilitates servicing. By using an ultra-thin 6-7 μm titanium foil window, solid-state power supplies, an innovative design to extract and spread the beam (enabling systems to be placed adjacent to each other to extend beam width) and touch-screen computer controls, these modular units combine ease of use and electrical transfer efficiency at voltages that can be varied between 80 kV and 150 kV with beam currents up to 40 mA per 25 cm across the beam window. These new devices have been made in three widths: 5 cm, 25 cm, and 40 cm. Details of the beam construction and illustrations of industrial uses will be presented. Traditional uses in the graphic arts and coatings areas have welcomed this modular technology as well as uses for surface sterilization. Being compact and lightweight (∼15 kg/emitter), these modular beams have been configured around complex shapes to achieve three-dimensional surface curing at high production rates

  8. Modular low-voltage electron emitters

    Science.gov (United States)

    Berejka, Anthony J.

    2005-12-01

    Modular, low-voltage electron emitters simplify electron beam (EB) technology for many industrial uses and for research and development. Modular electron emitters are produced in quantity as sealed systems that are evacuated at the factory, eliminating the need for vacuum pumps at the point of use. A plug-out-plug-in method of replacement facilitates servicing. By using an ultra-thin 6-7 μm titanium foil window, solid-state power supplies, an innovative design to extract and spread the beam (enabling systems to be placed adjacent to each other to extend beam width) and touch-screen computer controls, these modular units combine ease of use and electrical transfer efficiency at voltages that can be varied between 80 kV and 150 kV with beam currents up to 40 mA per 25 cm across the beam window. These new devices have been made in three widths: 5 cm, 25 cm, and 40 cm. Details of the beam construction and illustrations of industrial uses will be presented. Traditional uses in the graphic arts and coatings areas have welcomed this modular technology as well as uses for surface sterilization. Being compact and lightweight (∼15 kg/emitter), these modular beams have been configured around complex shapes to achieve three-dimensional surface curing at high production rates.

  9. Modified theoretical minimum emittance lattice for an electron storage ring with extreme-low emittance

    Directory of Open Access Journals (Sweden)

    Yi Jiao

    2011-05-01

    Full Text Available In the continuing efforts to reduce the beam emittance of an electron storage ring composed of theoretical minimum emittance (TME lattice, down to a level of several tens of picometers, nonlinear dynamics grows to be a great challenge to the performance of the storage ring because of the strong sextupoles needed to compensate for its large global natural chomaticities coupled with its small average dispersion function. To help in dealing with the challenge of nonlinear optimization, we propose a novel variation of theoretical minimum emittance (TME lattice, named as “modified-TME” lattice, with minimal emittance about 3 times of the exact theoretical minimum, while with more compact layout, lower phase advance per cell, smaller natural chromaticities, and more relaxed optical functions than that in a TME cell, by using horizontally defocusing quadrupole closer to the dipole or simply combined-function dipole with horizontally defocusing gradient. We present approximate scaling formulas to describe the relationships of the design parameters in a modified-TME cell. The applications of modified-TME lattice in the PEP-X storage ring design are illustrated and the proposed lattice appears a good candidate for synchrotron radiation light source with extremely low emittance.

  10. Standardization of Ga-68 by coincidence measurements, liquid scintillation counting and 4πγ counting

    International Nuclear Information System (INIS)

    Roteta, Miguel; Peyres, Virginia; Rodríguez Barquero, Leonor; García-Toraño, Eduardo; Arenillas, Pablo; Balpardo, Christian; Rodrígues, Darío; Llovera, Roberto

    2012-01-01

    The radionuclide 68 Ga is one of the few positron emitters that can be prepared in-house without the use of a cyclotron. It disintegrates to the ground state of 68 Zn partially by positron emission (89.1%) with a maximum energy of 1899.1 keV, and partially by electron capture (10.9%). This nuclide has been standardized in the frame of a cooperation project between the Radionuclide Metrology laboratories from CIEMAT (Spain) and CNEA (Argentina). Measurements involved several techniques: 4πβ−γ coincidences, integral gamma counting and Liquid Scintillation Counting using the triple to double coincidence ratio and the CIEMAT/NIST methods. Given the short half-life of the radionuclide assayed, a direct comparison between results from both laboratories was excluded and a comparison of experimental efficiencies of similar NaI detectors was used instead. - Highlights: ► We standardized the positron emitter Ga-68 in a bilateral cooperation. ► We used several techniques, as coincidence, integral gamma and liquid scintillation. ► An efficiency comparison replaced a direct comparison of reference materials.

  11. High brightness fiber laser pump sources based on single emitters and multiple single emitters

    Science.gov (United States)

    Scheller, Torsten; Wagner, Lars; Wolf, Jürgen; Bonati, Guido; Dörfel, Falk; Gabler, Thomas

    2008-02-01

    Driven by the potential of the fiber laser market, the development of high brightness pump sources has been pushed during the last years. The main approaches to reach the targets of this market had been the direct coupling of single emitters (SE) on the one hand and the beam shaping of bars and stacks on the other hand, which often causes higher cost per watt. Meanwhile the power of single emitters with 100μm emitter size for direct coupling increased dramatically, which also pushed a new generation of wide stripe emitters or multi emitters (ME) of up to 1000μm emitter size respectively "minibars" with apertures of 3 to 5mm. The advantage of this emitter type compared to traditional bars is it's scalability to power levels of 40W to 60W combined with a small aperture which gives advantages when coupling into a fiber. We show concepts using this multiple single emitters for fiber coupled systems of 25W up to 40W out of a 100μm fiber NA 0.22 with a reasonable optical efficiency. Taking into account a further efficiency optimization and an increase in power of these devices in the near future, the EUR/W ratio pushed by the fiber laser manufacturer will further decrease. Results will be shown as well for higher power pump sources. Additional state of the art tapered fiber bundles for photonic crystal fibers are used to combine 7 (19) pump sources to output powers of 100W (370W) out of a 130μm (250μm) fiber NA 0.6 with nominal 20W per port. Improving those TFB's in the near future and utilizing 40W per pump leg, an output power of even 750W out of 250μm fiber NA 0.6 will be possible. Combined Counter- and Co-Propagated pumping of the fiber will then lead to the first 1kW fiber laser oscillator.

  12. Coincidence summing corrections for positron emitters in germanium gamma spectrometry

    International Nuclear Information System (INIS)

    Richardson, A.E.; Sallee, W.W.; New Mexico State Univ., Las Cruces

    1990-01-01

    For positron emitters, 511 keV annihilation quanta are in coincidence with other gamma rays in the decay scheme. If the positrons are not localized at the point of decay, annihilation quanta will be produced at a site some distance from the point of emission. The magnitude of the summing coincidence effect will depend upon the position of annihilation. A method for determining the magnitude of the summing effect for a single gamma of energy E in coincidence with the annihilation gammas from non-localized positrons has been developed which makes use of the counting data for the full energy peaks for both the gamma ray (E) and the 511 keV annihilation gammas. With this data and efficiency calibration data one can determine the average total efficiency for the annihilation positions from which 511 keV gammas originate, and thereby obtain the summing correction factor, SCF, for gamma ray (E). Application of the method to a 22 Na NIST standard gave excellent agreement of observed emission rates for the 1275 keV gamma with the NIST value for wide ranging degrees of positron localization having summing correction factors ranging from 1.021 to 1.505. The method was also applied successfully to 58 Co in neutron-irradiated nickel foils. The method shows promise as a check on the accuracy of the efficiency calibration for a particular detector geometry at the 511 keV energy and energies for other gammas associated with positron emission. (orig.)

  13. Discriminator setting and cocktail preparation for analysis of alpha and beta emitters in aqueous solution using liquid scintillation counter

    International Nuclear Information System (INIS)

    Zaini Hamzah; Masitah Alias; Zaharudin Ahmad

    2011-01-01

    Liquid scintillation counting (LSC) is not only being used to measure pure beta emitters, but it can be used to measure both alpha and beta emitters simultaneously. Measurement of alpha and beta emitters in aqueous solution is done using a single sample. For the sample preparation, colorless detergent or emulsifier was used to incorporate the water into an organic based scintillator to produce a clear homogeneous solution, since this is the best form to give the highest count rate and detection efficiency. The instrument also need some attention, where after calibration, the LSC was set for the discriminator level which is suitable for measurement of both alpha and beta radiations. In this study, the focus is on the development of the best scintillation cocktail and establishes the best discriminator setting. From this study the best proportion of scintillation cocktail is 2:4:4 for water, toluene, and Triton-N101 (emulsifier) respectively and the best discriminator setting for alpha and beta counting are 120. (author)

  14. Platelet Count and Plateletcrit

    African Journals Online (AJOL)

    strated that neonates with late onset sepsis (bacteremia after 3 days of age) had a dramatic increase in MPV and. PDW18. We hypothesize that as the MPV and PDW increase and platelet count and PCT decrease in sick children, intui- tively, the ratio of MPV to PCT; MPV to Platelet count,. PDW to PCT, PDW to platelet ...

  15. EcoCount

    Directory of Open Access Journals (Sweden)

    Phillip P. Allen

    2014-05-01

    Full Text Available Techniques that analyze biological remains from sediment sequences for environmental reconstructions are well established and widely used. Yet, identifying, counting, and recording biological evidence such as pollen grains remain a highly skilled, demanding, and time-consuming task. Standard procedure requires the classification and recording of between 300 and 500 pollen grains from each representative sample. Recording the data from a pollen count requires significant effort and focused resources from the palynologist. However, when an adaptation to the recording procedure is utilized, efficiency and time economy improve. We describe EcoCount, which represents a development in environmental data recording procedure. EcoCount is a voice activated fully customizable digital count sheet that allows the investigator to continuously interact with a field of view during the data recording. Continuous viewing allows the palynologist the opportunity to remain engaged with the essential task, identification, for longer, making pollen counting more efficient and economical. EcoCount is a versatile software package that can be used to record a variety of environmental evidence and can be installed onto different computer platforms, making the adoption by users and laboratories simple and inexpensive. The user-friendly format of EcoCount allows any novice to be competent and functional in a very short time.

  16. Clean Hands Count

    Medline Plus

    Full Text Available ... starting stop Loading... Watch Queue Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with ... ads? Get YouTube Red. Working... Not now Try it free Find out why Close Clean Hands Count ...

  17. Counting It Twice.

    Science.gov (United States)

    Schattschneider, Doris

    1991-01-01

    Provided are examples from many domains of mathematics that illustrate the Fubini Principle in its discrete version: the value of a summation over a rectangular array is independent of the order of summation. Included are: counting using partitions as in proof by pictures, combinatorial arguments, indirect counting as in the inclusion-exclusion…

  18. Criteria for emittance compensation in high-brightness photoinjectors

    Directory of Open Access Journals (Sweden)

    Chun-xi Wang

    2007-10-01

    Full Text Available A critical process in high-brightness photoinjectors is emittance compensation, which brings under control the correlated transverse emittance growth due to the linear space-charge force. Although emittance compensation has been used and studied for almost two decades, the exact criteria to achieve emittance compensation is not as clear as it should be. In this paper, a perturbative analysis of slice envelopes and emittance evolution close to any reference envelope is developed, via which space-charge and chromatic effects are investigated. A new criterion for emittance compensation is found, which is complementary to the well-known matching condition for the invariant envelope and agrees very well with simulations.

  19. Quantum efficiency and thermal emittance of metal photocathodes

    Directory of Open Access Journals (Sweden)

    David H. Dowell

    2009-07-01

    Full Text Available Modern electron beams have demonstrated the brilliance needed to drive free electron lasers at x-ray wavelengths with major advances occurring since the invention of the photocathode gun and the realization of emittance compensation. These state-of-the-art electron beams are now becoming limited by the intrinsic thermal emittance of the cathode. In both dc and rf photocathode guns details of the cathode emission physics strongly influence the quantum efficiency and the thermal emittance. Therefore improving cathode performance is essential to increasing the brightness of beams. It is especially important to understand the fundamentals of cathode quantum efficiency and thermal emittance. This paper investigates the relationship between the quantum efficiency and the thermal emittance for metal cathodes using the Fermi-Dirac model for the electron distribution. We use a consistent theory to derive the quantum efficiency and thermal emittance, and compare our results to those of others.

  20. The Quantum Efficiency and Thermal Emittance of Metal Photocathodes

    International Nuclear Information System (INIS)

    Dowell, D.

    2009-01-01

    Modern electron beams have demonstrated the brilliance needed to drive free electron lasers at x-ray wavelengths, with the principle improvements occurring since the invention of the photocathode gun. The state-of-the-art normalized emittance electron beams are now becoming limited by the thermal emittance of the cathode. In both DC and RF photocathode guns, details of the cathode emission physics strongly influence the quantum efficiency and the thermal emittance. Therefore improving cathode performance is essential to increasing the brightness of beams. It is especially important to understand the fundamentals of cathode quantum efficiency and thermal emittance. This paper investigates the relationship between the quantum efficiency and the thermal emittance of metal cathodes using the Fermi-Dirac model for the electron distribution. We derive the thermal emittance and its relationship to the quantum efficiency, and compare our results to those of others

  1. Dielectric optical antenna thermal emitters and metamaterials

    Science.gov (United States)

    Schuller, Jonathan Aaron

    Optical antennas are critical components in nanophotonics research due to their unparalleled ability to concentrate electromagnetic energy into nanoscale volumes. Researchers typically construct such antennas from wavelength-size metallic structures. However, recent research has begun to exploit the scattering resonances of high-permittivity particles to realize all-dielectric optical antennas, emitters, and metamaterials. In this thesis, we experimentally and theoretically characterize the resonant modes of subwavelength rod-shaped dielectric particles and demonstrate their use in negative index metamaterials and novel infrared light emitters. At mid-infrared frequencies, Silicon Carbide (SiC) is an ideal system for studying the behavior of dielectric optical antennas. At frequencies below the TO phonon resonance, SiC behaves like a dielectric with very large refractive index. Using infrared spectroscopy and analytical Mie calculations we show that individual rod-shaped SiC particles exhibit a multitude of resonant modes. Detailed investigations of these SiC optical antennas reveal a wealth of new physics and applications. We discuss the distinct electromagnetic field profile for each mode, and demonstrate that two of the dielectric-type Mie resonances can be combined in a particle array to form a negative index metamaterial. We further show that these particles can serve as "broadcasting" antennas. Using a custom-built thermal emission microscope we collect emissivity spectra from single SiC particles at elevated temperatures, highlighting their use as subwavelength resonant light emitters. Finally, we derive and verify a variety of general analytical results applicable to all cylindrical dielectric antennas.

  2. Dielectric Optical Antenna Emitters and Metamaterials

    Science.gov (United States)

    Schuller, Jon

    2009-03-01

    Optical antennas are critical components in nanophotonics research due to their unparalleled ability to concentrate electromagnetic energy into nanoscale volumes. Researchers typically construct such antennas from wavelength-size metallic structures. However, recent research has begun to exploit the scattering resonances of high-permittivity particles to realize all-dielectric optical antennas, emitters, and metamaterials. In this talk, we experimentally and theoretically characterize the resonant modes of subwavelength rod-shaped dielectric particles and demonstrate their use in negative index metamaterials and novel infrared light emitters. At mid-infrared frequencies, Silicon Carbide (SiC) is an ideal system for studying the behavior of dielectric optical antennas. At frequencies below the TO phonon resonance, SiC behaves like a dielectric with very large refractive index. Using infrared spectroscopy and analytical Mie calculations we show that individual rod-shaped SiC particles exhibit a multitude of resonant modes. Detailed investigations of these SiC optical antennas reveal a wealth of new physics and applications. We discuss the distinct electromagnetic field profile for each mode, and demonstrate that two of the dielectric-type Mie resonances can be combined in a particle array to form a negative index metamaterial [1]. We further show that these particles can serve as ``broadcasting'' antennas. Using a custom-built thermal emission microscope we collect emissivity spectra from single SiC particles at elevated temperatures, highlighting their use as subwavelength resonant light emitters. Finally, we derive and verify a variety of general analytical results applicable to all cylindrical dielectric antennas and discuss extensions of the demonstrated concepts to different materials systems and frequency regimes. [1] J.A. Schuller, et al., Phys. Rev. Lett. 99, 107401 (2007)

  3. New therapeutic agent for radiation synovectomy - preparation of {sup 166}Ho-EDTMP-HA particle

    Energy Technology Data Exchange (ETDEWEB)

    Bai, H.; Jin, X.; Du, J.; Wang, F.; Chen, D.; Fan, H.; Cheng, Z.; Zhang, J. [China Institute of Atomic Energy, Beijing (Switzerland). Isotope Department

    1997-10-01

    In order to prepare new therapeutical agent for radiation synovectomy, Hydroxyapatite (HA) was labelled with {sup 166}Ho by EDTMP that had high affinity to HA particles. Radiolabelling of HA particles was divided into two steps, {sup 166}Ho-EDTMP was prepared first; then mixed with HA particles completely and vibrated for 15 minutes on the micromixer at room temperature, washed 3 times with deionized water. Radiolabelling particle was separated from free {sup 166}Ho via centrifugation to determine its radiolabelling efficiency. {sup 166}Ho-EDTMP-HA and {sup 166}Ho-EDTMP were injected into knee joint of normal rabbits respectively, every group was killed at different time postinjection, took out major organ and collected urine and blood, then weighted and determined their radio counts. HA particles, as a natural component of bone was known to have good compatibility with soft tissue and biodegrade into calcium and phosphate in vivo. It was readily prepared from common chemical and formed into particles of desired size range in a controlled process, it had high stability in vitro and vivo. Radiolabelling of HA particle with {sup 166}Ho by EDTMP was simple to perform and provides an excellent labelling yield that was more than 95% under the optimal labelling condition. The optimal labelling condition at room temperature was pH 6.0-8.0 and vibration time 15 minutes. The absorbed capacity of HA particle was 5 mg Ho/g HA particle and size of radiolabelling particle was at range of 2-5,{mu}m that is suitable for therapy of radiation synovectomy. {sup 166}Ho-EDTMP-HA particle demonstrated high in vitro stability in either normal saline or 1% BSA solution, but instability under extremely acidic condition (pH 1-2). The control studies performed with {sup 166}Ho-EDTMP not bound to HA particle provided information on the distribution of radioactivity that would occur upon leakage of the radiochemical compound from joint. Its short half-life, its extremely low leakage from the

  4. New therapeutic agent for radiation synovectomy - preparation of 166Ho-EDTMP-HA particle

    International Nuclear Information System (INIS)

    Bai, H.; Jin, X.; Du, J.; Wang, F.; Chen, D.; Fan, H.; Cheng, Z.; Zhang, J.

    1997-01-01

    In order to prepare new therapeutical agent for radiation synovectomy, Hydroxyapatite (HA) was labelled with 166 Ho by EDTMP that had high affinity to HA particles. Radiolabelling of HA particles was divided into two steps, 166 Ho-EDTMP was prepared first; then mixed with HA particles completely and vibrated for 15 minutes on the micromixer at room temperature, washed 3 times with deionized water. Radiolabelling particle was separated from free 166 Ho via centrifugation to determine its radiolabelling efficiency. 166 Ho-EDTMP-HA and 166 Ho-EDTMP were injected into knee joint of normal rabbits respectively, every group was killed at different time postinjection, took out major organ and collected urine and blood, then weighted and determined their radio counts. HA particles, as a natural component of bone was known to have good compatibility with soft tissue and biodegrade into calcium and phosphate in vivo. It was readily prepared from common chemical and formed into particles of desired size range in a controlled process, it had high stability in vitro and vivo. Radiolabelling of HA particle with 166 Ho by EDTMP was simple to perform and provides an excellent labelling yield that was more than 95% under the optimal labelling condition. The optimal labelling condition at room temperature was pH 6.0-8.0 and vibration time 15 minutes. The absorbed capacity of HA particle was 5 mg Ho/g HA particle and size of radiolabelling particle was at range of 2-5,μm that is suitable for therapy of radiation synovectomy. 166 Ho-EDTMP-HA particle demonstrated high in vitro stability in either normal saline or 1% BSA solution, but instability under extremely acidic condition (pH 1-2). The control studies performed with 166 Ho-EDTMP not bound to HA particle provided information on the distribution of radioactivity that would occur upon leakage of the radiochemical compound from joint. Its short half-life, its extremely low leakage from the joint and its even distribution throughout

  5. Investigations on cermet electrodes for thermionic emitters

    International Nuclear Information System (INIS)

    Schmidt, D.; Nazare, S.

    1975-01-01

    Unstable Ba 2 CaWO 6 -W with their own supply of Ba, as well as stable UO 2 -Mo-emitter cermets that have to be operated with an external Ba-source, have been prepared by axial hot pressing. The relevant properties of these cermets such as electrical resistivity and thermal expansion are reported and compared with theoretical predictions. The electron emission of these materials is discussed on the basis of the surface films formed. It provides the basis for optimising the behavior of these materials

  6. Multi-channel polarized thermal emitter

    Science.gov (United States)

    Lee, Jae-Hwang; Ho, Kai-Ming; Constant, Kristen P

    2013-07-16

    A multi-channel polarized thermal emitter (PTE) is presented. The multi-channel PTE can emit polarized thermal radiation without using a polarizer at normal emergence. The multi-channel PTE consists of two layers of metallic gratings on a monolithic and homogeneous metallic plate. It can be fabricated by a low-cost soft lithography technique called two-polymer microtransfer molding. The spectral positions of the mid-infrared (MIR) radiation peaks can be tuned by changing the periodicity of the gratings and the spectral separation between peaks are tuned by changing the mutual angle between the orientations of the two gratings.

  7. High efficiency quasi-monochromatic infrared emitter

    Energy Technology Data Exchange (ETDEWEB)

    Brucoli, Giovanni; Besbes, Mondher; Benisty, Henri, E-mail: henri.benisty@institutoptique.fr; Greffet, Jean-Jacques [Laboratoire Charles Fabry, UMR 8501, Institut d’Optique, CNRS, Université Paris-Sud 11, 2, Avenue Augustin Fresnel, 91127 Palaiseau Cedex (France); Bouchon, Patrick; Haïdar, Riad [Office National d’Études et de Recherches Aérospatiales, Chemin de la Hunière, 91761 Palaiseau (France)

    2014-02-24

    Incandescent radiation sources are widely used as mid-infrared emitters owing to the lack of alternative for compact and low cost sources. A drawback of miniature hot systems such as membranes is their low efficiency, e.g., for battery powered systems. For targeted narrow-band applications such as gas spectroscopy, the efficiency is even lower. In this paper, we introduce design rules valid for very generic membranes demonstrating that their energy efficiency for use as incandescent infrared sources can be increased by two orders of magnitude.

  8. Longitudinal emittance measurement at the ATS

    International Nuclear Information System (INIS)

    Cottingame, W.B.; Cortez, J.H.; Higgins, W.W.; Sander, O.R.; Sandoval, D.P.

    1986-01-01

    With increasing brightness, beam diagnostic techniques requiring interception of the beam become impractical. For H - particle beams, solutions for this problem based on the phenomenon of photodissociation are now being investigated at the Los Alamos National Laboratory accelerator test stand (ATS). A laser can be used to selectively neutralize portions of the beam than can be characterized after the charged particles have been swept away. We have used this technique for measuring longitudinal emittance at the output of the ATS radio-frequency quadrupole

  9. Emittance growth from transient coherent synchrotron radiation

    International Nuclear Information System (INIS)

    Bohn, C.L.; Li, R.; Bisognano, J.J.

    1996-01-01

    If the energies of individual particles in a bunch change as the bunch traverses a bending system, even if it is achromatic, betatron oscillations can be excited. Consequently, the transverse emittance of the bunch will grow as it moves downstream. Short bunches may be particularly susceptible to emission of coherent synchrotron radiation which can act back on the particles to change their energies and trajectories. Because a bend spans a well-defined length and angle, the bunch-excited wakefield and its effect back on the bunch are inherently transient. We outline a recently developed theory of this effect and apply it to example bending systems

  10. Tolerances for the vertical emittance in damping rings

    International Nuclear Information System (INIS)

    Raubenheimer, T.O.

    1991-11-01

    Future damping rings for linear colliders will need to have very small vertical emittances. In the limit of low beam current, the vertical emittance is primarily determined by the vertical dispersion and the betatron coupling. In this paper, the contributions to these effects from random misalignments are calculated and tolerances are derived to limit the vertical emittance with a 95% confidence level. 10 refs., 5 figs

  11. Emittance calculations for the Stanford Linear Collider injector

    International Nuclear Information System (INIS)

    Sheppard, J.C.; Clendenin, J.E.; Helm, R.H.; Lee, M.J.; Miller, R.H.; Blocker, C.A.

    1983-03-01

    A series of measurements have been performed to determine the emittance of the high intensity, single bunch beam that is to be injected into the Stanford Linear Collider. On-line computer programs were used to control the Linac for the purpose of data acquisition and to fit the data to a model in order to deduce the beam emittance. This paper will describe the method of emittance calculation and present some of the measurement results

  12. Measurement of emittance of metal interface in molten salt

    International Nuclear Information System (INIS)

    Araki, N.; Makino, A.; Nakamura, Y.

    1995-01-01

    A new technique for measuring the total normal emittance of a metal in a semi-transparent liquid has been proposed and this technique has been applied to measure the emittance of stainless steel (SUS304), nickel, and gold in molten potassium nitrate KNO 3 . These emittance data are indispensable to analyzing the radiative heat transfer between a metal and a semitransparent liquid, such as a molten salt

  13. Transverse beam emittance optimization for the injection into BESSY II

    Energy Technology Data Exchange (ETDEWEB)

    Kramer, Felix [Helmholtz Zentrum Berlin, Institut Beschleunigerphysik (Germany); Humboldt-Universitaet zu Berlin, Institut fuer Physik (Germany)

    2016-07-01

    For top up injection into the storage ring BESSY II an average injection efficiency of at least 90% is required. In low alpha mode the injection efficiency does not meet the requirements. Future BESSY II features will include shorter bunches in the storage ring (VSR) and user transparent injection with a non linear kicker. These will raise the demands on the quality of the injected beam even further. This work investigates the development of transverse emittance over the acceleration cycle in the synchrotron and the possibility of transverse emittance exchange by a sequence of skew quadrupoles in the transfer line. Results of emittance measurements and emittance exchange simulations will be given.

  14. Emittance Growth during Bunch Compression in the CTF-II

    Energy Technology Data Exchange (ETDEWEB)

    Raubenheimer, Tor O

    1999-02-26

    Measurements of the beam emittance during bunch compression in the CLIC Test Facility (CTF-II) are described. The measurements were made with different beam charges and different energy correlations versus the bunch compressor settings which were varied from no compression through the point of full compression and to over-compression. Significant increases in the beam emittance were observed with the maximum emittance occurring near the point of full (maximal) compression. Finally, evaluation of possible emittance dilution mechanisms indicate that coherent synchrotron radiation was the most likely cause.

  15. Dosimetry of internal emitters - quo vadis?

    International Nuclear Information System (INIS)

    Reddy, A.R.; Nagaratnam, A.; Jain, S.C.; Gupta, M.M.; Mehta, S.C.

    1999-01-01

    The dosimetry of internally administered radiopharmaceuticals in nuclear medicine procedures using MIRD formalisms and dosimetry in the case of intakes of radionuclides and ICRP methodology for the purpose of radiological protection are well established working practices. It should, however, be remembered that dose or dose coefficients calculated refer to a reference individual, defined in terms of a mathematical phantom established on the basis of certain biokinetic reference parameters. The reference individual represents a typical caucasian adult of West Europe or North American origin. Recently, some attempts have been made to define a Reference Asian and a Reference Indian individual and to assess the effects of anatomical differences and changes in the biokinetics of radiopharmaceuticals and other radionuclides in these different reference individuals on the estimation of dose and dose coefficients in relation to the intake of internal radionuclides. The assessment of doses to the embryo/fetus due to intake of radionuclides by pregnant women, local dose estimates, microdosimetry, radiobiology and radiation protection aspects relating to Auger electron emitters represent other areas of active research in the area of dosimetry of internal emitters. The present review summarises these different aspects of work. (orig.) [de

  16. Barium depletion in hollow cathode emitters

    International Nuclear Information System (INIS)

    Polk, James E.; Mikellides, Ioannis G.; Katz, Ira; Capece, Angela M.

    2016-01-01

    Dispenser hollow cathodes rely on a consumable supply of Ba released by BaO-CaO-Al 2 O 3 source material in the pores of a tungsten matrix to maintain a low work function surface. The examination of cathode emitters from long duration tests shows deposits of tungsten at the downstream end that appear to block the flow of Ba from the interior. In addition, a numerical model of Ba transport in the cathode plasma indicates that the Ba partial pressure in the insert may exceed the equilibrium vapor pressure of the dominant Ba-producing reaction, and it was postulated previously that this would suppress Ba loss in the upstream part of the emitter. New measurements of the Ba depletion depth from a cathode insert operated for 8200 h reveal that Ba loss is confined to a narrow region near the downstream end, confirming this hypothesis. The Ba transport model was modified to predict the depletion depth with time. A comparison of the calculated and measured depletion depths gives excellent qualitative agreement, and quantitative agreement was obtained assuming an insert temperature 70 °C lower than measured beginning-of-life values

  17. Emittance growth of bunched beams in bends

    International Nuclear Information System (INIS)

    Carlsten, B.E.; Raubenheimer, T.O.

    1995-01-01

    Talman [Phys. Rev. Lett. 56, 1429 (1986)] has proposed a novel relativistic effect that occurs when a charged particle beam is bent in the magnetic field from an external dipole. The consequence of this effect is that the space-charge forces from the particles do not exhibit the usual inverse-square energy dependence and some part of them are, in fact, independent of energy. This led to speculation that this effect could introduce significant emittance growth for a bending electron beam. Subsequently, it was shown that this effect's influence on the beam's transverse motion is canceled for a dc beam by a potential depression within the beam (to first order in the beam radius divided by the bend radius). In this paper, we extend the analysis to include short bunch lengths (as compared to the beam pipe dimensions) and find that there is no longer the cancellation for forces both transverse to and in the direction of motion. We provide an estimate for the emittance growth as a function of bend angle, beam radius, and current, and for magnetic compression of an electron bunch

  18. Emittance measurements from the LLUMC proton accelerator

    International Nuclear Information System (INIS)

    Coutrakon, G.; Gillespie, G.H.; Hubbard, J.; Sanders, E.

    2005-01-01

    A new method of calculating beam emittances at the extraction point of a particle accelerator is presented. The technique uses the optimization programs NPSOL and MINOS developed at Stanford University in order to determine the initial values of beam size, divergence and correlation parameters (i.e. beam sigma matrix, σ ij ) that best fit measured beam parameters. These σ ij elements are then used to compute the Twiss parameters α, β, and the phase space area, ε, of the beam at the extraction point. Beam size measurements in X and Y throughout the transport line were input to the optimizer along with the magnetic elements of bends, quads, and drifts. The σ ij parameters were optimized at the accelerator's extraction point by finding the best agreement between these measured beam sizes and those predicted by TRANSPORT. This expands upon a previous study in which a 'trial and error' technique was used instead of the optimizer software, and which yielded similar results. The Particle Beam Optics Laboratory (PBO Lab TM ) program used for this paper integrates particle beam optics and other codes into a single intuitive graphically-based computing environment. This new software provides a seamless interface between the NPSOL and MINOS optimizer and TRANSPORT calculations. The results of these emittance searches are presented here for the eight clinical energies between 70 and 250 MeV currently being used at LLUMC

  19. Narrowband infrared emitters for combat ID

    Science.gov (United States)

    Pralle, Martin U.; Puscasu, Irina; Daly, James; Fallon, Keith; Loges, Peter; Greenwald, Anton; Johnson, Edward

    2007-04-01

    There is a strong desire to create narrowband infrared light sources as personnel beacons for application in infrared Identify Friend or Foe (IFF) systems. This demand has augmented dramatically in recent years with the reports of friendly fire casualties in Afghanistan and Iraq. ICx Photonics' photonic crystal enhanced TM (PCE TM) infrared emitter technology affords the possibility of creating narrowband IR light sources tuned to specific IR wavebands (near 1-2 microns, mid 3-5 microns, and long 8-12 microns) making it the ideal solution for infrared IFF. This technology is based on a metal coated 2D photonic crystal of air holes in a silicon substrate. Upon thermal excitation the photonic crystal modifies the emitted yielding narrowband IR light with center wavelength commensurate with the periodicity of the lattice. We have integrated this technology with microhotplate MEMS devices to yield 15mW IR light sources in the 3-5 micron waveband with wall plug efficiencies in excess of 10%, 2 orders of magnitude more efficient that conventional IR LEDs. We have further extended this technology into the LWIR with a light source that produces 9 mW of 8-12 micron light at an efficiency of 8%. Viewing distances >500 meters were observed with fielded camera technologies, ideal for ground to ground troop identification. When grouped into an emitter panel, the viewing distances were extended to 5 miles, ideal for ground to air identification.

  20. Compact Rare Earth Emitter Hollow Cathode

    Science.gov (United States)

    Watkins, Ronald; Goebel, Dan; Hofer, Richard

    2010-01-01

    A compact, high-current, hollow cathode utilizing a lanthanum hexaboride (LaB6) thermionic electron emitter has been developed for use with high-power Hall thrusters and ion thrusters. LaB6 cathodes are being investigated due to their long life, high current capabilities, and less stringent xenon purity and handling requirements compared to conventional barium oxide (BaO) dispenser cathodes. The new cathode features a much smaller diameter than previously developed versions that permit it to be mounted on axis of a Hall thruster ( internally mounted ), as opposed to the conventional side-mount position external to the outer magnetic circuit ("externally mounted"). The cathode has also been reconfigured to be capable of surviving vibrational loads during launch and is designed to solve the significant heater and materials compatibility problems associated with the use of this emitter material. This has been accomplished in a compact design with the capability of high-emission current (10 to 60 A). The compact, high-current design has a keeper diameter that allows the cathode to be mounted on the centerline of a 6- kW Hall thruster, inside the iron core of the inner electromagnetic coil. Although designed for electric propulsion thrusters in spacecraft station- keeping, orbit transfer, and interplanetary applications, the LaB6 cathodes are applicable to the plasma processing industry in applications such as optical coatings and semiconductor processing where reactive gases are used. Where current electrical propulsion thrusters with BaO emitters have limited life and need extremely clean propellant feed systems at a significant cost, these LaB6 cathodes can run on the crudest-grade xenon propellant available without impact. Moreover, in a laboratory environment, LaB6 cathodes reduce testing costs because they do not require extended conditioning periods under hard vacuum. Alternative rare earth emitters, such as cerium hexaboride (CeB6) can be used in this

  1. Counting efficiency for liquid scintillator systems with a single multiplier phototube; Eficiencia de recuento en espectrometros de centelleo con un solo fotomultiplicador

    Energy Technology Data Exchange (ETDEWEB)

    Grau Malonda, A; Garcia-Torano, E

    1984-07-01

    In this paper counting efficiency as a function of a free parameter (the figure of merit) has been computed. The results are applicable to liquid scintillator systems with a single multiplier phototube. Tables of counting efficiency for 62 pure beta emitters are given for figures of merit in the range 0.25 to 50. (Author) 16 refs.

  2. Clean Hands Count

    Medline Plus

    Full Text Available ... Clean Hands Count Centers for Disease Control and Prevention (CDC) Loading... Unsubscribe from Centers for Disease Control and Prevention (CDC)? Cancel Unsubscribe Working... Subscribe Subscribed Unsubscribe 65K ...

  3. Clean Hands Count

    Medline Plus

    Full Text Available ... Clean Hands Count Centers for Disease Control and Prevention (CDC) Loading... Unsubscribe from Centers for Disease Control and Prevention (CDC)? Cancel Unsubscribe Working... Subscribe Subscribed Unsubscribe 66K ...

  4. Housing Inventory Count

    Data.gov (United States)

    Department of Housing and Urban Development — This report displays the data communities reported to HUD about the nature of their dedicated homeless inventory, referred to as their Housing Inventory Count (HIC)....

  5. Scintillation counting apparatus

    International Nuclear Information System (INIS)

    Noakes, J.E.

    1978-01-01

    Apparatus is described for the accurate measurement of radiation by means of scintillation counters and in particular for the liquid scintillation counting of both soft beta radiation and gamma radiation. Full constructional and operating details are given. (UK)

  6. Allegheny County Traffic Counts

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — Traffic sensors at over 1,200 locations in Allegheny County collect vehicle counts for the Pennsylvania Department of Transportation. Data included in the Health...

  7. Counting Knights and Knaves

    Science.gov (United States)

    Levin,Oscar; Roberts, Gerri M.

    2013-01-01

    To understand better some of the classic knights and knaves puzzles, we count them. Doing so reveals a surprising connection between puzzles and solutions, and highlights some beautiful combinatorial identities.

  8. Clean Hands Count

    Medline Plus

    Full Text Available ... why Close Clean Hands Count Centers for Disease Control and Prevention (CDC) Loading... Unsubscribe from Centers for Disease Control and Prevention (CDC)? Cancel Unsubscribe Working... Subscribe Subscribed ...

  9. Clean Hands Count

    Medline Plus

    Full Text Available ... stop Loading... Watch Queue Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. Working... Not now Try it free Find ...

  10. Adhesive strength of hydroxyl apatite(HA) coating and biomechanics behavior of HA-coated prosthesis:an experimental study

    OpenAIRE

    Tian-yang ZHANG; Yong-hong DUAN; Shu ZHU; Jin-yu ZHU; Qing-sheng ZHU

    2011-01-01

    Objective To explore the influence of adhesive strength of hydroxyapatite(HA) coating on the post-implantation stability of HA-coated prosthesis.Methods The adhesive strength and biomechanics behavior of HA coating were studied by histopathological observation,material parameters and biomechanical testing,the titanium(Ti)-coated prosthesis was employed as control.Results Scratch test showed that the adhesive strength of HA coating was significantly lower than that of Ti coating(P < 0.01).Hist...

  11. The Kruskal Count

    OpenAIRE

    Lagarias, Jeffrey C.; Rains, Eric; Vanderbei, Robert J.

    2001-01-01

    The Kruskal Count is a card trick invented by Martin J. Kruskal in which a magician "guesses" a card selected by a subject according to a certain counting procedure. With high probability the magician can correctly "guess" the card. The success of the trick is based on a mathematical principle related to coupling methods for Markov chains. This paper analyzes in detail two simplified variants of the trick and estimates the probability of success. The model predictions are compared with simula...

  12. Liquid scintillation counting techniques for the determination of some alpha emitting actinides: a review

    International Nuclear Information System (INIS)

    Mirashi, N.N.; Chander, Keshav; Aggarwal, S.K.

    2000-12-01

    The present report is a review of the work on liquid scintillation counting techniques, for the determination of alpha emitting actinides like uranium, plutonium, americium etc; for the last three decades (1970-1999). It covers the progress that has taken place in conventional liquid scintillation counting employing various solvents, scintillators and extractants. There is gradual development in instrumentation from integral counting of alpha emitters to alpha liquid scintillation spectrometry to resolve and identify different alpha emitters. These advancements have led to Pulse Shape Analysis (PSA) and Photon Electron Rejecting Alpha Liquid Scintillation Spectrometry (PERALS) techniques for the determination of the alpha emitters in the presence of beta and gamma activity. These techniques allow the determination of actinides at very low levels which has increased their applications to almost all the fields of chemistry; be it biomedical, environmental, geological or process chemistry of nuclear fuels. The development of biphasic technique using various extractants to separate different elements and counting in presence of one another has been made possible. Inorganic scintillators have been recently developed which have the advantage of eliminating effects of quenching and presence of beta/gamma emitting actinides. This review will serve as a reference to those who want to carry out work in the field of determination of actinides using liquid scintillation counting techniques. (author)

  13. Measurement of radionuclides using ion chromatography and flow-cell scintillation counting with pulse shape discrimination

    International Nuclear Information System (INIS)

    DeVol, T.A.; Fjeld, R.A.

    1995-01-01

    A project has been initiated at Clemson Univ. to develop a HPLC/flow- cell system for analysis of non-gamma emitting radionuclides in environmental samples; an important component is development of a low background flow-cell detector that counts alpha and beta particles separately through pulse shape discrimination. Objective of the work presented here is to provide preliminary results of an evaluation of the following scintillators: CaF 2 :Eu, scintillating glass, and BaF 2 . Slightly acidic aqueous solutions of the alpha emitter 233 U and the beta emitter 45 Ca were used. Detection efficiencies and minimum detectable activities were determined

  14. Movement of Irrigation Water in Soil from a Surface Emitter

    Directory of Open Access Journals (Sweden)

    Ibrahim Abbas Dawood

    2016-09-01

    Full Text Available rickle irrigation is one of the most conservative irrigation techniques since it implies supplying water directly on the soil through emitters. Emitters dissipate energy of water at the end of the trickle irrigation system and provide water at emission points. The area wetted by an emitter depends upon the discharge of emitter, soil texture, initial soil water content, and soil permeability. The objectives of this research were to predict water distribution profiles through different soils for different conditions and quantify the distribution profiles in terms of main characteristics of soil and emitter. The wetting patterns were simulated at the end of each hour for a total time of application of 12 hrs, emitter discharges of 0.5, 0.75, 1, 2, 3, 4, and 5 lph, and five initial volumetric soil water contents. Simulation of water flow from a single surface emitter was carried out by using the numerically-based software Hydrus-2D/3D, Version 2.04. Two approaches were used in developing formulas to predict the domains of the wetted pattern. In order to verify the results obtained by implementing the software Hydrus-2D/3D a field experiment was conducted to measure the wetted diameter and compare measured values with simulated ones. The results of the research showed that the developed formulas to express the wetted diameter and depth in terms of emitter discharge, time of application, and initial soil water content are very general and can be used with very good accuracy.

  15. Coupling of Quantum Emitters in Nanodiamonds to Plasmonic Structures

    DEFF Research Database (Denmark)

    Kumar, Shailesh

    This PhD thesis describes work towards the enhancement and efficient channeling of photons emitted from a single photon emitter. The emitter used is a defect center, the Nitrogen-Vacancy (NV) center, in diamond. The NV-center has many unique properties, such as long coherence time of its electron...

  16. Emittance growth due to dipole ripple and sextupole

    International Nuclear Information System (INIS)

    Shih, H.J.; Ellison, J.A.; Syphers, M.J.; Newberger, B.S.

    1993-05-01

    Ripple in the power supplies for storage ring magnets can have adverse effects on the circulating beams: orbit distortion and emittance growth from dipole ripple, tune modulation and dynamic aperture reduction from quadrupole ripple, etc. In this paper, we study the effects of ripple in the horizontal bending field of the SSC in the presence of nonlinearity, in particular, the growth in beam emittance

  17. Emittance growth due to negative-mass instability above transition

    International Nuclear Information System (INIS)

    Ng, King-Yuen.

    1994-08-01

    Due to space-charge effect, there is a growth of bunch emittance across transition as a result of negative-mass instability. The models of growth at cutoff frequency and growth from high-frequency Schottky noise are reviewed. The difficulties of performing reliable simulations are discussed. An intuitive self-bunching model for estimating emittance growth is presented

  18. Emittance formula for slits and pepper-pot measurement

    International Nuclear Information System (INIS)

    Zhang, M.

    1996-10-01

    In this note, a rigid formula for slits and pepper-pot emittance measurement is derived. The derivation is based on the one- dimensional slit measurement setup. A mathematical generalization of the slit emittance formula to the pepper-pot measurement is discussed

  19. MEV Energy Electrostatic Accelerator Ion Beam Emittance Measurement

    OpenAIRE

    I.G. Ignat’ev; M.I. Zakharets; S.V. Kolinko; D.P. Shulha

    2014-01-01

    The testing equipment was designed, manufactured and tried out permitting measurements of total current, current profile and emittance of an ion beam extracted from the ion beam. MeV energy electrostatic accelerator ion H + beam emittance measurement results are presented.

  20. Measurement of the transverse emittance for the NSC Pelletron

    International Nuclear Information System (INIS)

    Rodriques, G.; Mandal, A.; Chopra, S.; Joshi, R.; Datta, S.K.; Roy, A.

    1998-01-01

    The knowledge of the emittance (transverse and longitudinal) of the NSC pelletron is essential for matching the acceptance of the LINAC which is to be installed to augment the pelletron beam energies. The transverse emittance of NSC pelletron has been measured by employing a focussing element and a down-stream beam profile monitor

  1. Jamming of Quantum Emitters by Active Coated Nanoparticles

    DEFF Research Database (Denmark)

    Arslanagic, Samel; Ziolkowski, Richard W.

    2013-01-01

    to effectively cloak the emitters to a far-field observer is reported and explained through thorough near- and far-field investigations. This property offers an interesting route toward the jamming of quantum emitters/nanoantennas that might be of potential use, for instance, in biological fluorescence assays...

  2. Low emittance lattices for electron storage rings revisited

    International Nuclear Information System (INIS)

    Trbojevic, D.; Courant, E.

    1994-01-01

    Conditions for the lowest possible emittance of the lattice for electron storage rings are obtained by a simplified analytical approach. Examples of electron storage lattices with minimum emittances are presented. A simple graphical presentation in the normalized dispersion space (Floquet's transformation) is used to illustrate the conditions and results

  3. Evaluations of carbon nanotube field emitters for electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Nakahara, Hitoshi, E-mail: nakahara@nagoya-u.jp [Department of Quantum Engineering, Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan); Kusano, Yoshikazu; Kono, Takumi; Saito, Yahachi [Department of Quantum Engineering, Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan)

    2009-11-30

    Brightness of carbon nanotube (CNT) emitters was already reported elsewhere. However, brightness of electron emitter is affected by a virtual source size of the emitter, which strongly depends on electron optical configuration around the emitter. In this work, I-V characteristics and brightness of a CNT emitter are measured under a practical field emission electron gun (e-gun) configuration to investigate availability of CNT for electron microscopy. As a result, it is obtained that an emission area of MWNT is smaller than its tip surface area, and the emission area corresponds to a five-membered-ring with 2nd nearest six-membered-rings on the MWNT cap surface. Reduced brightness of MWNT is measured as at least 2.6x10{sup 9} A/m{sup 2} sr V. It is concluded that even a thick MWNT has enough brightness under a practical e-gun electrode configuration and suitable for electron microscopy.

  4. Evaluations of carbon nanotube field emitters for electron microscopy

    Science.gov (United States)

    Nakahara, Hitoshi; Kusano, Yoshikazu; Kono, Takumi; Saito, Yahachi

    2009-11-01

    Brightness of carbon nanotube (CNT) emitters was already reported elsewhere. However, brightness of electron emitter is affected by a virtual source size of the emitter, which strongly depends on electron optical configuration around the emitter. In this work, I- V characteristics and brightness of a CNT emitter are measured under a practical field emission electron gun (e-gun) configuration to investigate availability of CNT for electron microscopy. As a result, it is obtained that an emission area of MWNT is smaller than its tip surface area, and the emission area corresponds to a five-membered-ring with 2nd nearest six-membered-rings on the MWNT cap surface. Reduced brightness of MWNT is measured as at least 2.6×109 A/m 2 sr V. It is concluded that even a thick MWNT has enough brightness under a practical e-gun electrode configuration and suitable for electron microscopy.

  5. Emittance compensation of CW DC-gun photoinjector

    International Nuclear Information System (INIS)

    Li Peng; Wu Dai; Xu Zhou; Li Ming; Yang Xingfan

    2011-01-01

    Emittance growth induced by space charge effect is very important, especially for CW DC-gun photoinjector. In this work, the linear space charge force and its effect on electron beam transverse emittance are studied, and the principle and properties of emittance compensation by solenoid are analyzed. The CAEP DC-gun photoinjector with a solenoid is also simulated by code Parmela. Simulated results indicate that the normalized transverse emittance of an 80 pC bunch at the 350 keV DC-gun ex-it is 5.14 mm · mrad. And after compensated by a solenoid, it becomes 1.27 mm · mrad. The emittance of beam is well compensated. (authors)

  6. Internal Auger emitters: effects on spermatogenesis and oogenesis in mice

    International Nuclear Information System (INIS)

    Rao, D.V.; Mylavarapu, V.B.; Sastry, K.S.R.; Howell, R.W.

    1988-01-01

    The in vivo biological effects of Auger emitters are investigated using [A] spermatogenesis in mouse testis, and [B] oogenesis in mouse ovary as experimental models. Spermhead survival and induction of abnormal sperm, following intratesticular administration of radiopharmaceuticals, were the end points in Model A. Of interest in Model B is primary oocyte survival after intraperitoneal injection of the radiochemicals. The effectiveness of the Auger emitter is determined relative to its beta emitting companion or external X-rays in the absence of such an analogue. Results reveal pronounced effects of Auger emitters on all end points, not dependent on mode of administration. The efficacy of the Auger emitter is related intimately to its subcellular distribution, which, is governed by the chemical form of the carrier molecule. Conventional dosimetry is inadequate and biophysically meaningful dosimetric approaches are needed to understand in vivo effects of Auger emitters. (author)

  7. Plasma treatment for producing electron emitters

    Science.gov (United States)

    Coates, Don Mayo; Walter, Kevin Carl

    2001-01-01

    Plasma treatment for producing carbonaceous field emission electron emitters is disclosed. A plasma of ions is generated in a closed chamber and used to surround the exposed surface of a carbonaceous material. A voltage is applied to an electrode that is in contact with the carbonaceous material. This voltage has a negative potential relative to a second electrode in the chamber and serves to accelerate the ions toward the carbonaceous material and provide an ion energy sufficient to etch the exposed surface of the carbonaceous material but not sufficient to result in the implantation of the ions within the carbonaceous material. Preferably, the ions used are those of an inert gas or an inert gas with a small amount of added nitrogen.

  8. International Standardization of Pure Beta Emitters

    International Nuclear Information System (INIS)

    Los Arcos, Jose Maria; Rodriguez, Leonor

    2006-01-01

    The paper describes the traditional methods of standardization of Pure Beta Emitters, their principal characteristics, advantage and drawbacks. It does comparisons between two metrological LSC methods: Triple to double coincidence ratio (TDCR) method and the CIEMAT/NIST method and presents the result obtained with several Key Comparisons serving as practical test of both methods. Both of them represent the siferrit of methods of standardization of pure (and mixed decay) radionuclides. ESIR WG of CCRI(II) is to implement a reference exchange system for the permanent equivalence of β, α and electron capture nuclides, similar to traditional SIR gamma. ESIR project is currently testing a new XAN scintillator and operational tests of the whole system at BIPM are expected by the end of 2006 (test restricted to ESIR NMI members)

  9. Gamma emitters in Hong Kong water

    International Nuclear Information System (INIS)

    Shun-Yin, L.; Chung-Keung, M.; Wai-Kwok, N.; Shiu-Chun, A.

    1990-01-01

    Radioactivity in water originates from natural and artificial sources. The development of a nuclear powerplant near Hong Kong necessitates that attention be given to formulating techniques to assess the possible resultant environmental radioactive contamination. Water samples collected from various sites in Hong Kong in the spring and summer of 1987, representing seawater, river water, reservoir water, drinking water, and underground water were studied through gamma-ray spectral analysis. Only gamma emitters in the U238 and Th232 series and K40 were detected. No fission product was detected with specific activity above 0.1 Bq/kg. The data could be the baseline for future monitoring of the radioactivity released from a nuclear plant being built at a 50-km distance from Hong Kong. The variation of detected specific activities may be due to geological differences and the effect of plants. 1 ref., 3 tabs

  10. Beta-delayed proton emitter $^{113}Xe$

    CERN Document Server

    Hagberg, E; Jonson, B; Jørgensen, B; Kugler, E; Mowinckel, T

    1973-01-01

    The ISOLDE facility at the CERN synchrocyclotron has been used for extending the series of beta -delayed proton emitters in xenon to masses lighter than those previously observed (/sup 115,117/Xe). Owing to the rapid decrease of the yields, experiments with solid-state counters were inconclusive, and instead a new and much more sensitive method based on nuclear emulsions was developed. The mass range 111-114 showed one new activity, /sup 113/Xe, with a half-life of 2.8+or-0.2 sec. From measurements of the track lengths for a total of 1130 protons from /sup 113/Xe it was possible to determine the energy spectrum. The results extend the systematics of beta -strength functions in the light xenon isotopes. (19 refs).

  11. Passivated emitters in silicon solar cells

    International Nuclear Information System (INIS)

    King, R.R.; Gruenbaum, P.E.; Sinton, R.A.; Swanson, R.M.

    1990-01-01

    In high-efficiency silicon solar cells with low metal contact coverage fractions and high bulk lifetimes, cell performance is often dominated by recombination in the oxide-passivated diffusions on the cell surface. Measurements of the emitter saturation current density, J o , of oxide-passivated, boron and phosphorus diffusions are presented, and from these measurements, the dependence of surface recombination velocity on dopant concentration was extracted. The lowest observed values of J o which are stable under UV light are given for both boron- and phosphorus-doped, oxide-passivated diffusions, for both textured and untextured surfaces. Contour plots which incorporate the above data have been applied to two types of backside-contact solar cells with large area (37.5 cm 2 ) and one-sun efficiencies up to 22.7%

  12. Low White Blood Cell Count

    Science.gov (United States)

    Symptoms Low white blood cell count By Mayo Clinic Staff A low white blood cell count (leukopenia) is a decrease ... of white blood cell (neutrophil). The definition of low white blood cell count varies from one medical ...

  13. Radiation dosimetry in radiotherapy with internal emitters

    International Nuclear Information System (INIS)

    Stabin, Michael G.

    1997-01-01

    Full text. Radiation dosimetry radionuclides are currently being labeled to various biological agents used in internal emitter radiotherapy. This talk will review the various technologies and types of radiolabel in current use, with focus on the characterization of the radiation dose to the various important tissues of the body. Methods for obtaining data, developing kinetic models, and calculating radiation doses will be reviewed. Monoclonal antibodies are currently being labeled with both alpha and beta emitting radionuclides in attempts to find effective agents against cancer. Several radionuclides are also being used as bone pain palliation agents. These agents must be studied in clinical trials to determine the biokinetics and radiation dosimetry prior to approval for general use. In such studies, it is important to ensure the collection of the appropriate kinds of data and to collect the data at appropriate time intervals. The uptake and retention of activity in all significant source organs and in excreta be measured periodically (with at least 2 data points phase of uptake or clearance). Then, correct dosimetry methods must be applied - the best available methods for characterizing the radionuclide kinetic and for estimating the dosimetry in the various organs of the body especially the marrow, should be used. Attempts are also under way to develop methods for estimating true patient-specific dosimetry. Cellular and animal studies are also. Valuable in evaluating the efficacy of the agents in shrinking or eliminating tumors; some results from such studies will also be discussed. The estimation of radiation doses to patients in therapy with internal emitters involves several complex phases of analysis. Careful attention to detail and the use of the best available methods are essential to the protection of the patient and a successful outcome

  14. Theory and measurements of emittance preservation in plasma wakefield acceleration

    Energy Technology Data Exchange (ETDEWEB)

    Frederico, Joel

    2016-12-01

    In this dissertation, we examine the preservation and measurement of emittance in the plasma wakefield acceleration blowout regime. Plasma wakefield acceleration (PWFA) is a revolutionary approach to accelerating charged particles that has been demonstrated to have the potential for gradients orders of magnitude greater than traditional approaches. The application of PWFA to the design of a linear collider will make new high energy physics research possible, but the design parameters must first be shown to be competitive with traditional methods. Emittance preservation is necessary in the design of a linear collider in order to maximize luminosity. We examine the conditions necessary for circular symmetry in the PWFA blowout regime, and demonstrate that current proposals meet these bounds. We also present an application of beam lamentation which describes the process of beam parameter and emittance matching. We show that the emittance growth saturates as a consequence of energy spread in the beam. The initial beam parameters determine the amount of emittance growth, while the contribution of energy spread is negligible. We also present a model for ion motion in the presence of a beam that is much more dense than the plasma. By combining the model of ion motion and emittance growth, we find the emittance growth due to ion motion is minimal in the case of marginal ion motion. In addition, we present a simulation that validates the ion motion model, which is under further development to examine emittance growth of both marginal and pronounced ion motion. Finally, we present a proof-of-concept of an emittance measurement which may enable the analysis of emittance preservation in future PWFA experiments.

  15. Comparison between arc drops in ignited thermionic converters with and without ion reflections at the emitter

    International Nuclear Information System (INIS)

    Lundgren, L.

    1985-01-01

    The output performance of two thermionic energy converters is compared. One converter has a normal emitter, working with zero field at the emitter which is close to the optimum working point, and the other has a low work function emitter and ion reflection at the emitter. A simple model of the plasma and the sheaths shows that a converter working with a low work function emitter and ion reflections gives a worse performance than a similar converter with a normal emitter

  16. Cooperative spontaneous emission of nano-emitters with inter-emitter coupling in a leaky microcavity

    International Nuclear Information System (INIS)

    Hong, Suc-Kyoung; Nam, Seog Woo; Yang, Hyung Jin

    2015-01-01

    We study the spontaneous emission from a few two-level nano-emitters placed in a leaky microcavity with Lorentzian spectral density near a critically damped regime. Collective features of the spontaneous emission are investigated by numerical analysis of the excitation dynamics when initially one nano-emitter is totally excited but we do not know which one. The results show that there are three decay rates in the excitation dynamics, two for simple exponential decays and one for damped oscillatory decay. The excitation dynamics is found to critically depend on the regime of the system. It is shown that the spontaneous emission is enhanced or suppressed depending on whether the system is in the underdamped or overdamped regime, respectively. On the other hand, the cooperative spontaneous emission is suppressed in the underdamped while it is enhanced in the overdamped regime. Furthermore, the effect of the direct inter-emitter coupling on the breaking of the cooperativeness of the spontaneous emission is shown as well. (paper)

  17. Alpha scintillation radon counting

    International Nuclear Information System (INIS)

    Lucas, H.F. Jr.

    1977-01-01

    Radon counting chambers which utilize the alpha-scintillation properties of silver activated zinc sulfide are simple to construct, have a high efficiency, and, with proper design, may be relatively insensitive to variations in the pressure or purity of the counter filling. Chambers which were constructed from glass, metal, or plastic in a wide variety of shapes and sizes were evaluated for the accuracy and the precision of the radon counting. The principles affecting the alpha-scintillation radon counting chamber design and an analytic system suitable for a large scale study of the 222 Rn and 226 Ra content of either air or other environmental samples are described. Particular note is taken of those factors which affect the accuracy and the precision of the method for monitoring radioactivity around uranium mines

  18. Principles of correlation counting

    International Nuclear Information System (INIS)

    Mueller, J.W.

    1975-01-01

    A review is given of the various applications which have been made of correlation techniques in the field of nuclear physics, in particular for absolute counting. Whereas in most cases the usual coincidence method will be preferable for its simplicity, correlation counting may be the only possible approach in such cases where the two radiations of the cascade cannot be well separated or when there is a longliving intermediate state. The measurement of half-lives and of count rates of spurious pulses is also briefly discussed. The various experimental situations lead to different ways the correlation method is best applied (covariance technique with one or with two detectors, application of correlation functions, etc.). Formulae are given for some simple model cases, neglecting dead-time corrections

  19. Interpretation of galaxy counts

    International Nuclear Information System (INIS)

    Tinsely, B.M.

    1980-01-01

    New models are presented for the interpretation of recent counts of galaxies to 24th magnitude, and predictions are shown to 28th magnitude for future comparison with data from the Space Telescope. The results supersede earlier, more schematic models by the author. Tyson and Jarvis found in their counts a ''local'' density enhancement at 17th magnitude, on comparison with the earlier models; the excess is no longer significant when a more realistic mixture of galaxy colors is used. Bruzual and Kron's conclusion that Kron's counts show evidence for evolution at faint magnitudes is confirmed, and it is predicted that some 23d magnitude galaxies have redshifts greater than unity. These may include spheroidal systems, elliptical galaxies, and the bulges of early-type spirals and S0's, seen during their primeval rapid star formation

  20. [Construction of porous hydroxyapatite (HA) block loaded with cultured chondrocytes].

    Science.gov (United States)

    Yan, M; Dang, G

    1999-07-01

    To construct a kind of bone healing enhancing implant with cultured chondrocytes bound to hydroxyapatite (HA). Chondrocytes were obtained from the costicartilage of rat and were cultured on the porous HA blocks, 3 mm x 3 mm x 4 mm size, for three and seven days. Scanning electron micrograph was taken to show whether the cells grew outside and inside the pore of HA block. The cells cultured on tiny glass sheet for 2 days were used to prove where the cells come from by in situ hybridization technique with alpha1 (II) cDNA probe. Scanning electron micrographs showed that the pores of the HA surface and inside of the blocks are filled with cultured cells, especially the longer cultured block. The cells were chondrocytes confirmed by in situ hybridization. The porous HA can be used as cell cultured substrate and chondrocyte can adhere and proliferate inside the porous HA block.

  1. Effect of n-HA with different surface-modified on the properties of n-HA/PLGA composite

    Energy Technology Data Exchange (ETDEWEB)

    Jiang Liuyun, E-mail: jlytxg@163.com [Chengdu Institute of Organic Chemistry, Chinese Academy of Sciences, Chengdu 610041 (China); Xiong Chengdong; Chen Dongliang [Chengdu Institute of Organic Chemistry, Chinese Academy of Sciences, Chengdu 610041 (China); Jiang Lixin [Chengdu Institute of Organic Chemistry, Chinese Academy of Sciences, Chengdu 610041 (China); Graduated School of Chinese Academy of Sciences, Beijing 100039 (China); Pang Xiubing [Zhejiang Apeloa Medical Technology Co. Ltd, Jinhua 322118 (China)

    2012-10-15

    Graphical abstract: The bend strength of n-HA/PLGA composite with the unmodified n-HA becomes lower than that of PLGA. However, when n-HA was modified by different methods, the bend strength of g-n-HA/PLGA composites gets a little increase than PLGA, and the g3-n-HA/PLGA shows the highest bend strength at 3% g3-n-HA loading amount in weight, reached 162 MPa, which was 24.4% higher than that of pure PLGA. Highlights: Black-Right-Pointing-Pointer A new surface modification method for n-HA of combining stearic acid with surface-grafting L-lactic was adopted. Black-Right-Pointing-Pointer Three different surface modification methods for n-HA were compared in detail. Black-Right-Pointing-Pointer The new surface modification method was the most ideal method in this study. Black-Right-Pointing-Pointer The g3-n-HA/PLGA composite had the highest bending strength, which would be potential to be used as bone fracture internal fixation materials. - Abstract: Three different surface modification methods for nano-hydroxyapatite (n-HA) of stearic acid, grafted with L-lactide, combining stearic acid and surface-grafting L-lactic were adopted, respectively. The surface modification reaction and the effect of different methods were evaluated by Fourier transformation infrared (FTIR), X-ray photoelectron spectra (XPS), thermal gravimetric analysis (TGA), transmission electron microscopy (TEM). The results showed that n-HA surfaces were all successful modified, and the modification method of combining stearic acid and surface-grafting L-lactic had the greatest grafting amount and the best dispersion among the three modification methods. Then, the n-HA with three different surface modification and unmodified n-HA were introduced into PLGA, respectively, and a serials of n-HA/PLGA composites with 3% n-HA amount in weight were prepared by solution mixing, and the properties of n-HA/PLGA composites were also investigated by electromechanical universal tester and scanning electron

  2. Computerized radioautographic grain counting

    International Nuclear Information System (INIS)

    McKanna, J.A.; Casagrande, V.A.

    1985-01-01

    In recent years, radiolabeling techniques have become fundamental assays in physiology and biochemistry experiments. They also have assumed increasingly important roles in morphologic studies. Characteristically, radioautographic analysis of structure has been qualitative rather than quantitative, however, microcomputers have opened the door to several methods for quantifying grain counts and density. The overall goal of this chapter is to describe grain counting using the Bioquant, an image analysis package based originally on the Apple II+, and now available for several popular microcomputers. The authors discuss their image analysis procedures by applying them to a study of development in the central nervous system

  3. Rainflow counting revisited

    Energy Technology Data Exchange (ETDEWEB)

    Soeker, H [Deutsches Windenergie-Institut (Germany)

    1996-09-01

    As state of the art method the rainflow counting technique is presently applied everywhere in fatigue analysis. However, the author feels that the potential of the technique is not fully recognized in wind energy industries as it is used, most of the times, as a mere data reduction technique disregarding some of the inherent information of the rainflow counting results. The ideas described in the following aim at exploitation of this information and making it available for use in the design and verification process. (au)

  4. Recovering the triple coincidence of non-pure positron emitters in preclinical PET

    Science.gov (United States)

    Lin, Hsin-Hon; Chuang, Keh-Shih; Chen, Szu-Yu; Jan, Meei-Ling

    2016-03-01

    Non-pure positron emitters, with their long half-lives, allow for the tracing of slow biochemical processes which cannot be adequately examined by the commonly used short-lived positron emitters. Most of these isotopes emit high-energy cascade gamma rays in addition to positron decay that can be detected and create a triple coincidence with annihilation photons. Triple coincidence is discarded in most scanners, however, the majority of the triple coincidence contains true photon pairs that can be recovered. In this study, we propose a strategy for recovering triple coincidence events to raise the sensitivity of PET imaging for non-pure positron emitters. To identify the true line of response (LOR) from a triple coincidence, a framework utilizing geometrical, energy and temporal information is proposed. The geometrical criterion is based on the assumption that the LOR with the largest radial offset among the three sub pairs of triple coincidences is least likely to be a true LOR. Then, a confidence time window is used to test the valid LOR among those within triple coincidence. Finally, a likelihood ratio discriminant rule based on the energy probability density distribution of cascade and annihilation gammas is established to identify the true LOR. An Inveon preclinical PET scanner was modeled with GATE (GEANT4 application for tomographic emission) Monte Carlo software. We evaluated the performance of the proposed method in terms of identification fraction, noise equivalent count rates (NECR), and image quality on various phantoms. With the inclusion of triple coincidence events using the proposed method, the NECR was found to increase from 11% to 26% and 19% to 29% for I-124 and Br-76, respectively, when 7.4-185 MBq of activity was used. Compared to the reconstructed images using double coincidence, this technique increased the SNR by 5.1-7.3% for I-124 and 9.3-10.3% for Br-76 within the activity range of 9.25-74 MBq, without compromising the spatial resolution or

  5. Emittance variations in current-amplifying ion induction linacs

    International Nuclear Information System (INIS)

    Fessenden, T.J.

    1991-01-01

    Since 1985 the Heavy Ion Fusion Accelerator Research program at the Lawrence Berkeley Laboratory has been studying current amplification and emittance variations in MBE-4, a four-cesium-beam induction linac. This experiment models much of the accelerator physics of the electrostatically focused section of a fusion driver. Four space-charge dominated Cs + beams, initially about one meter in length at currents of 5-10 mA, are focused by electrostatic quadrupoles and accelerated in parallel from approximately 200 keV up to one MeV by 24 accelerating gaps. Final currents of 20-40 mA per beam are typical. Recent experiments with extremely low emittance beams (var-epsilon n =0.03 mm-mRad) have investigated variations of transverse and longitudinal normalized emittance for drifting and accelerating beams. These very strongly tune-depressed beams (σ 0 =72 degree, σ∼6 degree) are difficult to match to the accelerator so as to avoid emittance growth during acceleration. During transport strong emittance fluctuations are observed in good qualitative agreement with simulations. Warmer beams with less tune depression exhibit little to no emittance growth, show smaller emittance fluctuations, and are much easier to match. A summary of findings from the MBE-4 studies is presented

  6. Emittance variations in current-amplifying ion induction linacs

    International Nuclear Information System (INIS)

    Fessenden, T.J.

    1991-04-01

    Since 1985 the Heavy Ion Fusion Accelerator Research program at the Lawrence Berkeley Laboratory has been studying current amplification and emittance variations in MBE-4, a four-cesium-beam induction linac. This experiment models much of the accelerator physics of the electrostatically focused section of a fusion driver. Four space-charge dominated Cs + beams, initially about one meter in length at currents of 5--10 mA, are focused by electrostatic quadrupoles and accelerated in parallel from approximately 200 keV up to one MeV by 24 accelerating gaps. Final currents of 20--40 mA per beam are typical. Recent experiments with extremely low emittance beams (ε n = 0.03 mm-mRad) have investigated variations of transverse and longitudinal normalized emittance for drifting and accelerating beams. These very strongly tune-depressed beams (σ o = 72 degrees, σ∼6 degree) are difficult to match the accelerator so as to avoid emittance growth during acceleration. During transport strong emittance fluctuations are observed in good qualitative agreement with simulations. Warmer beams with less tune depression exhibit little to no emittance growth, show smaller emittance fluctuations, and are much easier to match. A summary of findings from the MBE-4 studies is presented. 12 refs., 8 figs

  7. Emittance and beam size distortion due to linear coupling

    International Nuclear Information System (INIS)

    Parzen, G.

    1993-01-01

    At injection, the presence of linear coupling may result in an increased beam emittance and in increased beam dimensions. Results for the emittance in the presence of linear coupling will be found. These results for the emittance distortion show that the harmonics of the skew quadrupole field close to ν x + ν y are the important harmonics. Results will be found for the important driving terms for the emittance distortion. It will be shown that if these driving terms are corrected, then the total emittance is unchanged, var-epsilon x + var-epsilon y = var-epsilon 1 + var-epsilon 2 . Also, the increase in the beam dimensions will be limited to a factor which is less than 1.414. If the correction is good enough, see below for details, one can achieve var-epsilon 1 = var-epsilon x , var-epsilon 2 = var-epsilon where var-epsilon 1 , var-epsilon 2 are the emittances in the presence of coupling, and the beam dimensions are unchanged. Global correction of the emittance and beam size distortion appears possible

  8. Measurement of concentrations of {gamma}-ray emitters induced in the concrete shield of the JAERI electron linac facility

    Energy Technology Data Exchange (ETDEWEB)

    Endo, Akira; Kawasaki, Katsuya; Kikuchi, Masamitsu [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Harada, Yasunori

    1997-07-01

    Measurement has been made to study distributions of {gamma}-ray emitters induced in the concrete shield of the JAERI electron linac facility. Core boring was carried out at seven positions to take samples from the concrete shield, and {gamma}-ray counting rates and {gamma}-ray spectra of these samples were measured with a NaI(Tl) detector and a Ge semiconductor detector, respectively. The following radionuclides were detected in the concrete samples: {sup 60}Co, {sup 134}Cs, {sup 152}Eu and {sup 154}Eu generated through thermal neutron capture reaction, and {sup 22}Na and {sup 54}Mn generated through nuclear reactions by bremsstrahlung and fast neutrons. The relation between the distributions of {gamma}-ray emitters, as a function of the depth of concrete, and the positions of core boring is discussed. (author)

  9. Few emitters in a cavity: from cooperative emission to individualization

    International Nuclear Information System (INIS)

    Auffeves, A; Portolan, S; Gerace, D; Drezet, A; Franca Santos, M

    2011-01-01

    We study the temporal correlations of the field emitted by an electromagnetic resonator coupled to a mesoscopic number of two-level emitters that are incoherently pumped by a weak external drive. We solve the master equation of the system for increasing number of emitters and as a function of the cavity quality factor, and we identify three main regimes characterized by well-distinguished statistical properties of the emitted radiation. For small cavity decay rates, the emission events are uncorrelated and the number of photons in the emitted field becomes larger than one, resembling the build-up of a laser field inside the cavity. At intermediate decay rates (as compared with the emitter-cavity coupling) and for a few emitters, the statistics of the emitted radiation is bunched and strikingly dependent on the parity of the number of emitters. The latter property is related to the cooperativity of the emitters mediated by their coupling to the cavity mode, and its connection with steady-state subradiance is discussed. Finally, in the bad cavity regime the typical situation of emission from a collection of individual emitters is recovered. We also analyze how the cooperative behavior evolves as a function of pure dephasing, which allows us to recover the case of a classical source made of an ensemble of independent emitters, similar to what is obtained for a very leaky cavity. State-of-the-art techniques of Q-switch of resonant cavities, allied with the recent capability of tuning single emitters in and out of resonance, suggest this system to be a versatile source of different quantum states of light.

  10. Few emitters in a cavity: from cooperative emission to individualization

    Energy Technology Data Exchange (ETDEWEB)

    Auffeves, A; Portolan, S [CEA/CNRS/UJF Joint Team ' Nanophysics and Semiconductors' , Institut Neel-CNRS, BP 166, 25 Rue des Martyrs, 38042 Grenoble Cedex 9 (France); Gerace, D [Dipartimento di Fisica ' Alessandro Volta' and UdR CNISM, Universita di Pavia, via Bassi 6, 27100 Pavia (Italy); Drezet, A [Institut Neel-CNRS, BP 166, 25 Rue des Martyrs, 38042 Grenoble Cedex 9 (France); Franca Santos, M, E-mail: msantos@fisica.ufmg.br [Departamento de Fisica, Universidade Federal de Minas Gerais, Belo Horizonte, CP 702, 30123-970 (Brazil)

    2011-09-15

    We study the temporal correlations of the field emitted by an electromagnetic resonator coupled to a mesoscopic number of two-level emitters that are incoherently pumped by a weak external drive. We solve the master equation of the system for increasing number of emitters and as a function of the cavity quality factor, and we identify three main regimes characterized by well-distinguished statistical properties of the emitted radiation. For small cavity decay rates, the emission events are uncorrelated and the number of photons in the emitted field becomes larger than one, resembling the build-up of a laser field inside the cavity. At intermediate decay rates (as compared with the emitter-cavity coupling) and for a few emitters, the statistics of the emitted radiation is bunched and strikingly dependent on the parity of the number of emitters. The latter property is related to the cooperativity of the emitters mediated by their coupling to the cavity mode, and its connection with steady-state subradiance is discussed. Finally, in the bad cavity regime the typical situation of emission from a collection of individual emitters is recovered. We also analyze how the cooperative behavior evolves as a function of pure dephasing, which allows us to recover the case of a classical source made of an ensemble of independent emitters, similar to what is obtained for a very leaky cavity. State-of-the-art techniques of Q-switch of resonant cavities, allied with the recent capability of tuning single emitters in and out of resonance, suggest this system to be a versatile source of different quantum states of light.

  11. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 824 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 409,492 ...

  12. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 786 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 413,702 ...

  13. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 414 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson ...

  14. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 869 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  15. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 460 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson ...

  16. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 741 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  17. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 029 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 411,974 ...

  18. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 396 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson ...

  19. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 094 views 1:19 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 411,974 ...

  20. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 319 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  1. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 585 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 413,097 ...

  2. Detection and counting systems

    International Nuclear Information System (INIS)

    Abreu, M.A.N. de

    1976-01-01

    Detection devices based on gaseous ionization are analysed, such as: electroscopes ionization chambers, proportional counters and Geiger-Mueller counters. Scintillation methods are also commented. A revision of the basic concepts in electronics is done and the main equipment for counting is detailed. In the study of gama spectrometry, scintillation and semiconductor detectors are analysed [pt

  3. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 384 views 1:19 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson ...

  4. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 285 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  5. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 033 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  6. Reticulocyte Count Test

    Science.gov (United States)

    ... htm. (2004 Summer). Immature Reticulocyte Fraction(IRF). The Pathology Center Newsletter v9(1). [On-line information]. Available ... Company, Philadelphia, PA [18th Edition]. Levin, M. (2007 March 8, Updated). Reticulocyte Count. MedlinePlus Medical Encyclopedia [On- ...

  7. Clean Hands Count

    Medline Plus

    Full Text Available ... is starting stop Loading... Watch Queue Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos ... empower patients to play a role in their care by asking or reminding healthcare providers to clean ...

  8. Radiation intensity counting system

    International Nuclear Information System (INIS)

    Peterson, R.J.

    1982-01-01

    A method is described of excluding the natural dead time of the radiation detector (or eg Geiger-Mueller counter) in a ratemeter counting circuit, thus eliminating the need for dead time corrections. Using a pulse generator an artificial dead time is introduced which is longer than the natural dead time of the detector. (U.K.)

  9. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 043 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 411,292 ...

  10. Calorie count - fast food

    Science.gov (United States)

    ... GO About MedlinePlus Site Map FAQs Customer Support Health Topics Drugs & Supplements Videos & Tools Español You Are Here: Home → Medical Encyclopedia → Calorie count - fast food URL of this page: //medlineplus.gov/ency/patientinstructions/ ...

  11. Fast counting electronics for neutron coincidence counting

    International Nuclear Information System (INIS)

    Swansen, J.E.

    1987-01-01

    This patent describes a high speed circuit for accurate neutron coincidence counting comprising: neutron detecting means for providing an above-threshold signal upon neutron detection; amplifying means inputted by the neutron detecting means for providing a pulse output having a pulse width of about 0.5 microseconds upon the input of each above threshold signal; digital processing means inputted by the pulse output of the amplifying means for generating a pulse responsive to each input pulse from the amplifying means and having a pulse width of about 50 nanoseconds effective for processing an expected neutron event rate of about 1 Mpps: pulse stretching means inputted by the digital processing means for producing a pulse having a pulse width of several milliseconds for each pulse received form the digital processing means; visual indicating means inputted by the pulse stretching means for producing a visual output for each pulse received from the digital processing means; and derandomizing means effective to receive the 50 ns neutron event pulses from the digital processing means for storage at a rate up to the neutron event rate of 1 Mpps and having first counter means for storing the input neutron event pulses

  12. Design of a minimum emittance nBA lattice

    Science.gov (United States)

    Lee, S. Y.

    1998-04-01

    An attempt to design a minimum emittance n-bend achromat (nBA) lattice has been made. One distinct feature is that dipoles with two different lengths were used. As a multiple bend achromat, five bend achromat lattices with six superperiod were designed. The obtained emittace is three times larger than the theoretical minimum. Tunes were chosen to avoid third order resonances. In order to correct first and second order chromaticities, eight family sextupoles were placed. The obtained emittance of five bend achromat lattices is almost equal to the minimum emittance of five bend achromat lattice consisting of dipoles with equal length.

  13. Remote detection of single emitters via optical waveguides

    Science.gov (United States)

    Then, Patrick; Razinskas, Gary; Feichtner, Thorsten; Haas, Philippe; Wild, Andreas; Bellini, Nicola; Osellame, Roberto; Cerullo, Giulio; Hecht, Bert

    2014-05-01

    The integration of lab-on-a-chip technologies with single-molecule detection techniques may enable new applications in analytical chemistry, biotechnology, and medicine. We describe a method based on the reciprocity theorem of electromagnetic theory to determine and optimize the detection efficiency of photons emitted by single quantum emitters through truncated dielectric waveguides of arbitrary shape positioned in their proximity. We demonstrate experimentally that detection of single quantum emitters via such waveguides is possible, confirming the predicted behavior of the detection efficiency. Our findings blaze the trail towards efficient lensless single-emitter detection compatible with large-scale optofluidic integration.

  14. Multi-dimensional beam emittance and β-functions

    International Nuclear Information System (INIS)

    Buon, J.

    1993-05-01

    The concept of r.m.s. emittance is extended to the case of several degrees of freedom that are coupled. That multi-dimensional emittance is lower than the product of the emittances attached to each degree of freedom, but is conserved in a linear motion. An envelope-hyperellipsoid is introduced to define the β-functions of the beam envelope. On the contrary of an one-degree of freedom motion, it is emphasized that these envelope functions differ from the amplitude functions of the normal modes of motion as a result of the difference between the Liouville and Lagrange invariants. (author) 4 refs

  15. Engineered Emitters for Improved Silicon Photovoltaics

    Science.gov (United States)

    Kamat, Ronak A.

    In 2014, installation of 5.3GW of new Photovoltaic (PV) systems occurred in the United States, raising the total installed capacity to 16.36GW. Strong growth is predicted for the domestic PV market with analysts reporting goals of 696GW by 2020. Conventional single crystalline silicon cells are the technology of choice, accounting for 90% of the installations in the global commercial market. Cells made of GaAs offer higher efficiencies, but at a substantially higher cost. Thin film technologies such as CIGS and CdTe compete favorably with multi-crystalline Si (u-Si), but at 20% efficiency, still lag the c-Si cell in performance. The c-Si cell can be fabricated to operate at approximately 25% efficiency, but commercially the efficiencies are in the 18-21% range, which is a direct result of cost trade-offs between process complexity and rapid throughput. With the current cost of c-Si cell modules at nearly 0.60/W. The technology is well below the historic metric of 1/W for economic viability. The result is that more complex processes, once cost-prohibitive, may now be viable. An example is Panasonic's HIT cell which operates in the 22-24% efficiency range. To facilitate research and development of novel PV materials and techniques, RIT has developed a basic solar cell fabrication process. Student projects prior to this work had produced cells with 12.8% efficiency using p type substrates. This thesis reports on recent work to improve cell efficiencies while simultaneously expanding the capability of the rapid prototyping process. In addition to the p-Si substrates, cells have been produced using n-Si substrates. The cell emitter, which is often done with a single diffusion or implant has been re-engineered using a dual implant of the same dose. This dual-implanted emitter has been shown to lower contact resistance, increase Voc, and increase the efficiency. A p-Si substrate cell has been fabricated with an efficiency of 14.6% and n-Si substrate cell with a 13

  16. Improved Rare-Earth Emitter Hollow Cathode

    Science.gov (United States)

    Goebel, Dan M.

    2011-01-01

    An improvement has been made to the design of the hollow cathode geometry that was created for the rare-earth electron emitter described in Compact Rare Earth Emitter Hollow Cathode (NPO-44923), NASA Tech Briefs, Vol. 34, No. 3 (March 2010), p. 52. The original interior assembly was made entirely of graphite in order to be compatible with the LaB6 material, which cannot be touched by metals during operation due to boron diffusion causing embrittlement issues in high-temperature refractory materials. Also, the graphite tube was difficult to machine and was subject to vibration-induced fracturing. This innovation replaces the graphite tube with one made out of refractory metal that is relatively easy to manufacture. The cathode support tube is made of molybdenum or molybdenum-rhenium. This material is easily gun-bored to near the tolerances required, and finish machined with steps at each end that capture the orifice plate and the mounting flange. This provides the manufacturability and robustness needed for flight applications, and eliminates the need for expensive e-beam welding used in prior cathodes. The LaB6 insert is protected from direct contact with the refractory metal tube by thin, graphite sleeves in a cup-arrangement around the ends of the insert. The sleeves, insert, and orifice plate are held in place by a ceramic spacer and tungsten spring inserted inside the tube. To heat the cathode, an insulating tube is slipped around the refractory metal hollow tube, which can be made of high-temperature materials like boron nitride or aluminum nitride. A screw-shaped slot, or series of slots, is machined in the outside of the ceramic tube to constrain a refractory metal wire wound inside the slot that is used as the heater. The screw slot can hold a single heater wire that is then connected to the front of the cathode tube by tack-welding to complete the electrical circuit, or it can be a double slot that takes a bifilar wound heater with both leads coming out

  17. Võidupüha 8. mail? / Leonti Kährik

    Index Scriptorium Estoniae

    Kährik, Leonti

    2005-01-01

    Eesti peaks väärikalt tähistama võidupüha kui euroopalike demokraatlike väärtuste võitu natsismi ja fašismi üle. Lähtudes 1940. a. juunini Eestis kehtinud vööndiajast, võiks võidupüha tähistada 8. mail

  18. Hafnium carbide nanocrystal chains for field emitters

    International Nuclear Information System (INIS)

    Tian, Song; Li, Hejun; Zhang, Yulei; Ren, Jincui; Qiang, Xinfa; Zhang, Shouyang

    2014-01-01

    A hafnium carbide (HfC) nanostructure, i.e., HfC nanocrystal chain, was synthesized by a chemical vapor deposition (CVD) method. X-ray diffractometer, field-emission scanning electron microscope, transmission electron microscope, and energy-dispersive X-ray spectrometer were employed to characterize the product. The synthesized one-dimensional (1D) nanostructures with many faceted octahedral nanocrystals possess diameters of tens of nanometers to 500 nm and lengths of a few microns. The chain-like structures possess a single crystalline structure and preferential growth direction along the [1 0 0] crystal orientation. The growth of the chains occurred through the vapor–liquid–solid process along with a negative-feedback mechanism. The field emission (FE) properties of the HfC nanocrystal chains as the cold cathode emitters were examined. The HfC nanocrystal chains display good FE properties with a low turn-on field of about 3.9 V μm −1 and a high field enhancement factor of 2157, implying potential applications in vacuum microelectronics.

  19. Sources of Emittance in RF Photocathode Injectors

    Energy Technology Data Exchange (ETDEWEB)

    Dowell, David [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2016-12-11

    Advances in electron beam technology have been central to creating the current generation of x-ray free electron lasers and ultra-fast electron microscopes. These once exotic devices have become essential tools for basic research and applied science. One important beam technology for both is the electron source which, for many of these instruments, is the photocathode RF gun. The invention of the photocathode gun and the concepts of emittance compensation and beam matching in the presence of space charge and RF forces have made these high-quality beams possible. Achieving even brighter beams requires a taking a finer resolution view of the electron dynamics near the cathode during photoemission and the initial acceleration of the beam. In addition, the high brightness beam is more sensitive to degradation by the optical aberrations of the gun’s RF and magnetic lenses. This paper discusses these topics including the beam properties due to fundamental photoemission physics, space charge effects close to the cathode, and optical distortions introduced by the RF and solenoid fields. Analytic relations for these phenomena are derived and compared with numerical simulations.

  20. Preparation of bioactive porous HA/PCL composite scaffolds

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, J.; Guo, L.Y.; Yang, X.B. [Key Laboratory of Advanced Technologies of Materials (Ministry of Education), School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031 (China); Weng, J. [Key Laboratory of Advanced Technologies of Materials (Ministry of Education), School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031 (China)], E-mail: jweng@swjtu.cn

    2008-12-30

    Porous hydroxyapatite (HA) bioceramic scaffold has been widely attracted the attention to act as a three-dimensional (3D) template for cell adhesion, proliferation, differentiation and thus promoting bone and cartilage regeneration because of its osteoinduction. However, the porous bioceramic scaffold is fragile so that it is not suitable to be applied in clinic for bone repair or replacement. Therefore, it is significant to improve the mechanical property of porous HA bioceramics while the interconnected structure is maintained for tissue ingrowth in vivo. In the present research, a porous composite scaffold composed of HA scaffold and polycaprolactone (PCL) lining was fabricated by the method of polymer impregnating to produce HA scaffold coated with PCL lining. Subsequently, the composite scaffolds were deposited with biomimetic coating for improving the bioactivity. The HA/PCL composite scaffolds with improved mechanical property and bioactivity is expected to be a promising bone substitute in tissue engineering applications.

  1. Preparation of bioactive porous HA/PCL composite scaffolds

    International Nuclear Information System (INIS)

    Zhao, J.; Guo, L.Y.; Yang, X.B.; Weng, J.

    2008-01-01

    Porous hydroxyapatite (HA) bioceramic scaffold has been widely attracted the attention to act as a three-dimensional (3D) template for cell adhesion, proliferation, differentiation and thus promoting bone and cartilage regeneration because of its osteoinduction. However, the porous bioceramic scaffold is fragile so that it is not suitable to be applied in clinic for bone repair or replacement. Therefore, it is significant to improve the mechanical property of porous HA bioceramics while the interconnected structure is maintained for tissue ingrowth in vivo. In the present research, a porous composite scaffold composed of HA scaffold and polycaprolactone (PCL) lining was fabricated by the method of polymer impregnating to produce HA scaffold coated with PCL lining. Subsequently, the composite scaffolds were deposited with biomimetic coating for improving the bioactivity. The HA/PCL composite scaffolds with improved mechanical property and bioactivity is expected to be a promising bone substitute in tissue engineering applications

  2. Electrospun Porous PDLLA Fiber Membrane Coated with nHA

    Directory of Open Access Journals (Sweden)

    Linhui Qiang

    2018-05-01

    Full Text Available Porous poly- D, L-lactic acid (PDLLA electrospinning fiber membrane was prepared, and nano-hydroxyapatite (nHA was adsorbed and wrapped into it during the unique shrinking process of the PDLLA fiber membrane to fabricate the PDLLA/nHA composite membrane scaffold for tissue engineering. Compare with the composite fibers prepared by blend electrospinning, most of nHA particles are observed to distribute on the surface of new type composite fibers, which could significantly improve the water wettability and induce the cellular adherence. FTIR analysis indicated that the PDLLA/nHA composite fibrous membrane was formed by physical adsorption. The combination was probed by scanning electron microscope, thermo-gravimetric, water contact angle and mechanical property analysis. It was proved that the nHA particles’ content and distribution, surface wettability, modulus and tensile strength of PDLLA/nHA composite fibrous membrane were influenced by the concentration of nHA dispersion and pores on the PDLLA fiber surface. The 10.6 wt % PDLLA/nHA composite fibrous membrane exhibits a more balanced tensile strength (3.28 MPa and surface wettability (with a water contact angle of 0° of the composite mats. Scanning electron microscope and confocal laser scanning microscopy images of chondrocyte proliferation further showed that the composite scaffold is non-toxic. The adherence and proliferation of chondrocytes on the 10.6 wt % PDLLA/nHA fibrous membrane was significantly improved, compared with PDLLA mat. The 10.6 wt % PDLLA/nHA composite fibrous membrane has potential application value as scaffold material in tissue engineering.

  3. A numerical study of emittance growths in RF guns

    CERN Document Server

    Masuda, K; Sobajima, M; Kitagaki, J; Ohnishi, M; Toku, H; Yoshikawa, K

    1999-01-01

    A beam with greatly reduced emittance is required for further improvements of FELs, in particular, for FELs of shorter wavelengths, and of narrower bandwidths. From this viewpoint, the BNL/SLAC/UCLA 1.6-cell S-band photocathode RF gun performance characteristics were calculated, first in order to evaluate what may contribute to the emittance growths in photocathode RF guns. We developed an RF gun to produce an electron beam with an extremely low emittance, by using a 2-D simulation code. It is found that, by optimizing the laser injection phase, the drive laser spot radius and the cavity shape around the laser spot, the beam emittance by the 1.6-cell RF gun can be greatly reduced to 2.1 pi mm mrad, from the previous 4.4 pi mm mrad of the original shape.

  4. An Online Multisensor Data Fusion Framework for Radar Emitter Classification

    Directory of Open Access Journals (Sweden)

    Dongqing Zhou

    2016-01-01

    Full Text Available Radar emitter classification is a special application of data clustering for classifying unknown radar emitters in airborne electronic support system. In this paper, a novel online multisensor data fusion framework is proposed for radar emitter classification under the background of network centric warfare. The framework is composed of local processing and multisensor fusion processing, from which the rough and precise classification results are obtained, respectively. What is more, the proposed algorithm does not need prior knowledge and training process; it can dynamically update the number of the clusters and the cluster centers when new pulses arrive. At last, the experimental results show that the proposed framework is an efficacious way to solve radar emitter classification problem in networked warfare.

  5. Emittance measuring unit for 100% duty factor linac injector beams

    Energy Technology Data Exchange (ETDEWEB)

    Shubaly, M R; Pachner, J Jr; Ormrod, J H; Ungrin, J; Schriber, S O [ed.

    1976-11-01

    A description is given of a system to measure the emittance of a 750 keV 100 mA dc proton beam suitable for injection into a 100% duty factor linear accelerator. A relatively slowly pulsed 45/sup 0/ magnet switches the beam to a beam dump inside the emittance measuring unit for approx. 10 s. A fast pulsed 5/sup 0/ magnet then deflects the beam to a multiple aperture ''pepper-pot'' plate for 300 ..mu..s. Beamlets passing through the plate travel 520 mm and produce a pattern on a scintillator screen. A photograph of the pattern is analyzed to determine beam emittance. Preliminary results on low current beams show a gross increase in the emittance in the horizontal plane.

  6. Localization of Narrowband Single Photon Emitters in Nanodiamonds.

    Science.gov (United States)

    Bray, Kerem; Sandstrom, Russell; Elbadawi, Christopher; Fischer, Martin; Schreck, Matthias; Shimoni, Olga; Lobo, Charlene; Toth, Milos; Aharonovich, Igor

    2016-03-23

    Diamond nanocrystals that host room temperature narrowband single photon emitters are highly sought after for applications in nanophotonics and bioimaging. However, current understanding of the origin of these emitters is extremely limited. In this work, we demonstrate that the narrowband emitters are point defects localized at extended morphological defects in individual nanodiamonds. In particular, we show that nanocrystals with defects such as twin boundaries and secondary nucleation sites exhibit narrowband emission that is absent from pristine individual nanocrystals grown under the same conditions. Critically, we prove that the narrowband emission lines vanish when extended defects are removed deterministically using highly localized electron beam induced etching. Our results enhance the current understanding of single photon emitters in diamond and are directly relevant to fabrication of novel quantum optics devices and sensors.

  7. Innovative energy efficient low-voltage electron beam emitters

    International Nuclear Information System (INIS)

    Felis, Kenneth P.; Avnery, Tovi; Berejka, Anthony J.

    2002-01-01

    Advanced electron beams (AEB) has developed a modular, low voltage (80-125 keV), high beam current (up to 40 ma), electron emitter with typically 25 cm of beam width, that is housed in an evacuated, returnable chamber that is easy to plug in and connect. The latest in nanofabrication enables AEB to use an ultra-thin beam window. The power supply for AEB's emitter is based on solid-state electronics. This combination of features results in a remarkable electrical efficiency. AEB's electron emitter relies on a touch screen, computer control system. With 80 μm of unit density beam penetration, AEB's electron emitter has gained market acceptance in the curing of opaque, pigmented inks and coatings used on flexible substrates, metals and fiber composites and in the curing of adhesives in foil based laminates

  8. Innovative energy efficient low-voltage electron beam emitters

    Science.gov (United States)

    Felis, Kenneth P.; Avnery, Tovi; Berejka, Anthony J.

    2002-03-01

    Advanced electron beams (AEB) has developed a modular, low voltage (80-125 keV), high beam current (up to 40 ma), electron emitter with typically 25 cm of beam width, that is housed in an evacuated, returnable chamber that is easy to plug in and connect. The latest in nanofabrication enables AEB to use an ultra-thin beam window. The power supply for AEB's emitter is based on solid-state electronics. This combination of features results in a remarkable electrical efficiency. AEB's electron emitter relies on a touch screen, computer control system. With 80 μm of unit density beam penetration, AEB's electron emitter has gained market acceptance in the curing of opaque, pigmented inks and coatings used on flexible substrates, metals and fiber composites and in the curing of adhesives in foil based laminates.

  9. Emittance measurements in low energy ion storage rings

    Science.gov (United States)

    Hunt, J. R.; Carli, C.; Resta-López, J.; Welsch, C. P.

    2018-07-01

    The development of the next generation of ultra-low energy antiproton and ion facilities requires precise information about the beam emittance to guarantee optimum performance. In the Extra-Low ENergy Antiproton storage ring (ELENA) the transverse emittances will be measured by scraping. However, this diagnostic measurement faces several challenges: non-zero dispersion, non-Gaussian beam distributions due to effects of the electron cooler and various systematic errors such as closed orbit offsets and inaccurate rms momentum spread estimation. In addition, diffusion processes, such as intra-beam scattering might lead to emittance overestimates. Here, we present algorithms to efficiently address the emittance reconstruction in presence of the above effects, and present simulation results for the case of ELENA.

  10. Very bright, near-infrared single photon emitters in diamond

    Directory of Open Access Journals (Sweden)

    D. W. M. Lau

    2013-09-01

    Full Text Available We demonstrate activation of bright diamond single photon emitters in the near infrared range by thermal annealing alone, i.e., without ion implantation. The activation is crucially dependent on the annealing ambient. The activation of the single photon emitters is only observed when the sample is annealed in forming gas (4% H2 in Ar above temperatures of 1000 °C. By contrast, no emitters are activated by annealing in vacuum, oxygen, argon or deuterium. The emitters activated by annealing in forming gas exhibit very bright emission in the 730-760 nm wavelength range and have linewidths of ∼1.5-2.5 nm at room temperature.

  11. Transverse Emittance Measurement and Preservation at the LHC

    CERN Document Server

    AUTHOR|(CDS)2082907

    The Large Hadron Collider (LHC) at CERN is a high energy storage ring that provides proton and heavy ion collisions to study fundamental particle physics. The luminosity production is closely linked to emittance preservation in the accelerator. The transverse emittance is the phase space density of the beam and should be conserved when the particle beam is transformed through the accelerator. Perturbing effects, however, can lead to emittance increase and hence luminosity degradation. Measuring the emittance growth is a complex task with high intensity beams and changing energies. The machine optics and the transverse beam size have to be measured as accurately as possible. Beta function measurements with k-modulation will be discussed. With this method the quadrupole focussing strength is varied and the resulting tune change is traced to determine the beta function at the quadrupole. A new k-modulation measurement tool was developed for the LHC. The fully automatic and online measurement system takes constra...

  12. Beam dynamics in rf guns and emittance correction techniques

    International Nuclear Information System (INIS)

    Serafini, L.

    1994-01-01

    In this paper we present a general review of beam dynamics in a laser-driven rf gun. The peculiarity of such an accelerating structure versus other conventional multi-cell linac structures is underlined on the basis of the Panofsky-Wenzel theorem, which is found to give a theoretical background for the well known Kim's model. A basic explanation for some proposed methods to correct rf induced emittance growth is also derived from the theorem. We also present three emittance correction techniques for the recovery of space-charge induced emittance growth, namely the optimum distributed disk-like bunch technique, the use of rf spatial harmonics to correct spherical aberration induced by space charge forces and the technique of emittance filtering by clipping the electron beam. The expected performances regarding the beam quality achievable with different techniques, as predicted by scaling laws and simulations, are analyzed, and, where available, compared to experimental results. (orig.)

  13. Transverse emittance measurement at REGAE via a solenoid scan

    Energy Technology Data Exchange (ETDEWEB)

    Hachmann, Max

    2012-12-15

    The linear accelerator REGAE at DESY produces short and low charged electron bunches, on the one hand to resolve the excitation transitions of atoms temporally by pump probe electron diffraction experiments and on the other hand to investigate principal mechanisms of laser plasma acceleration. For both cases a high quality electron beam is required. A quantity to rate the beam quality is the beam emittance. In the course of this thesis transverse emittance measurements by a solenoid scan could be realized and beyond that an improved theoretical description of a solenoid was successful. The foundation of emittance measurements are constituted by theoretical models which describe the envelope of a beam. Two different models were derived. The first is an often used model to determine the transverse beam emittance without considering space charge effects. More interesting and challenging was the development of an envelope model taking space charge effects into account. It is introduced and cross checked with measurements and simulations.

  14. Design for a practical, low-emittance damping ring

    International Nuclear Information System (INIS)

    Krejcik, P.

    1988-01-01

    The luminosity requirements for future high-energy linear colliders calls for very low emittances in the two beams. These low emittances can be achieved with damping rings, but, in order to reach the design goal of a factor 10 improvement over present day machines, great care must be taken in their design. This paper emphasizes the need to address simultaneously all of the factors which limit the operational emittance in the ring. Particularly since in standard designs there is a conflict between different design parameters which makes it difficult to extrapolate such designs to very low emittances. The approach chosen here is to resolve such conflicts by separating their design solutions. Wigglers are used predominantly in zero-dispersion regions to achieve the desired damping rate, whereas in the arcs high dispersion insertions are made in regions of zero curvature to allow for easier chromaticity control

  15. Emittance increase caused by core depletion in collisions

    CERN Document Server

    Bruce, R

    2009-01-01

    A new effect is presented, which changes the emittance during colliding-beam operation in circular colliders. If the initial transverse distribution is Gaussian, the collision probability is much higher for particles in the core of the beam than in the tails. When small-amplitude particles are removed, the remaining ones therefore have a larger transverse emittance. This effect, called core depletion, may cause a decrease in luminosity. An approximate analytic model is developed to study the effect and benchmarked against a multiparticle tracking simulation. Finally, the time evolution of the intensity and emittances of a Pb bunch in the Large Hadron Collider (LHC) at CERN is calculated, taking into account also other processes than collisions. The results show that integrated luminosity drops by 3--4% if core depletion is taken into account. It is also found that core depletion causes the transverse emittance to be larger when more experiments are active. This observation could be checked against experimenta...

  16. Simulation studies of emittance growth in RMS mismatched beams

    International Nuclear Information System (INIS)

    Cucchetti, A.; Wangler, T.; Reiser, M.

    1991-01-01

    As shown in a separate paper, a charged-particle beam, whose rms size is not matched when injected into a transport channel or accelerator, has excess energy compared with that of a matched beam. If nonlinear space-charge forces are present and the mismatched beam transforms to a matched equilibrium state, rms-emittance growth will occur. The theory yields formulas for the possible rms-emittance growth, but not for the time it takes to achieve this growth. In this paper we present the results of systematic simulation studies for a mismatched 2-D round beam in an ideal transport channel with continuous linear focusing. Emittance growth rates obtained from the simulations for different amounts of mismatch and initial charge will be presented and the emittance growth will be compared with the theory. 6 refs., 7 figs

  17. CSR-induced emittance growth in achromats: Linear formalism revisited

    Energy Technology Data Exchange (ETDEWEB)

    Venturini, M.

    2015-09-11

    We review the R-matrix formalism used to describe Coherent Synchrotron Radiation (CSR)-induced projected emittance growth in electron beam transport lines and establish the connection with a description in terms of the dispersion-invariant function.

  18. Progress on low emittance tuning for the CLIC Damping Rings

    CERN Document Server

    Alabau-Gonzalvo, J; Papaphilippou, Y

    2014-01-01

    In the frame of the CLIC main Damping Ring a study on the sensitivity of the lattice to different sources of misalignment is presented. The minimum equilibrium emittance is simulated and analytically estimated under dipole and quadrupole rolls, and quadrupole and sextupole vertical offsets. The result of this study establishes alignment tolerances to preserve the vertical emittance below the design value (1 pmrad). Non-linear dynamics studies have been done to determine the dynamic aperture in the presence of misalignments.

  19. Emittance growth from rotated quadrupoles in heavy ion accelerators

    International Nuclear Information System (INIS)

    Barnard, J.J.

    1995-01-01

    We derive a set of moment equations which incorporates linear quadrupolar focusing and space-charge defocusing, in the presence of rotational misalignments of the quadrupoles about the direction of beam propagation. Although the usual beam emittance measured relative to fixed transverse x and y coordinate axes is not constant, a conserved emittance-like quantity has been found. Implications for alignment tolerances in accelerators for heavy-ion inertial fusion are discussed

  20. Minimum emittance of isochronus rings for synchrotron light source

    CERN Document Server

    Shoji, Y

    1999-01-01

    Theoretically achievable minimum emittances of isochronus rings for synchrotron light source are calculated. The rings discussed in this paper consist of isochronus and achromatic bending cells, isochronus TBA (triple bend achromat) cells with negative dispersion, isochronus TBA cells with inverse bends or isochronus QBA (four bend achromat) cells. We show that the minimum emittances of these rings are roughly 2 or 3 times of those of the optimized non-isochronus rings.

  1. Quantum emitters coupled to surface plasmons of an nanowire

    DEFF Research Database (Denmark)

    Dzsotjan, David; Sørensen, Anders Søndberg; Fleischhauer, Michael

    2010-01-01

    We investigate a system consisting of a single, as well as two emitters strongly coupled to surface plasmon modes of a nanowire using a Green's function approach. Explicit expressions are derived for the spontaneous decay rate into the plasmon modes and for the atom-plasmon coupling as well......-qubit quantum gate. We also discuss a possible realization of interesting many-body Hamiltonians, such as the spin-boson model, using strong emitter-plasmon coupling. Udgivelsesdato: 27 August...

  2. Transverse emittance measurement at REGAE via a solenoid scan

    Energy Technology Data Exchange (ETDEWEB)

    Hachmann, Max; Mayet, Frank; Gruener, Florian [Institut fuer Experimentalphysik, Universitaet Hamburg (Germany); Floettmann, Klaus [DESY, Hamburg (Germany)

    2013-07-01

    The linear accelerator REGAE at DESY produces short and low charged electron bunches, on the one hand to resolve the excitation transitions of atoms temporally by pump probe electron diffraction experiments and on the other hand to investigate principal mechanisms of laser plasma acceleration. For both cases a high quality electron beam is required which can be identified with a small beam emittance. The current method to measure the transverse beam emittance at REGAE and results are presented.

  3. Internal emitter limits for iodine, radium and radon daughters

    Energy Technology Data Exchange (ETDEWEB)

    Schlenker, R.A.

    1984-08-15

    This paper identifies some of the issues which arise in the consideration of the derivation of new limits on exposure to internal emitters. Basic and secondary radiation protection limits are discussed. Terms are defined and applied to the limitation of risk from stochastic effects. Non-stochastic data for specific internal emitters (/sup 131/I and the radium isotopes) are presented. Emphasis is placed on the quantitative aspects of the limit setting problem. 65 references, 2 figures, 12 tables.

  4. Internal emitter limits for iodine, radium and radon daughters

    International Nuclear Information System (INIS)

    Schlenker, R.A.

    1984-01-01

    This paper identifies some of the issues which arise in the consideration of the derivation of new limits on exposure to internal emitters. Basic and secondary radiation protection limits are discussed. Terms are defined and applied to the limitation of risk from stochastic effects. Non-stochastic data for specific internal emitters ( 131 I and the radium isotopes) are presented. Emphasis is placed on the quantitative aspects of the limit setting problem. 65 references, 2 figures, 12 tables

  5. A Program to Generate a Particle Distribution from Emittance Measurements

    CERN Document Server

    Bouma, DS; Lallement, JB

    2010-01-01

    We have written a program to generate a particle distribution based on emittance measurements in x-x’ and y-y’. The accuracy of this program has been tested using real and constructed emittance measurements. Based on these tests, the distribution generated by the program can be used to accurately simulate the beam in multi-particle tracking codes, as an alternative to a Gaussian or uniform distribution.

  6. Internal emitter dosimetry: are patient-specific calculations necessary?

    International Nuclear Information System (INIS)

    Sgouros, G.

    1996-01-01

    Full text: The question of whether patient-specific calculations are needed in internal emitter dosimetry arises when radionuclides are used for therapy. In diagnostic procedures the absorbed dose delivered to normal tissue is far below hazardous levels. In internal emitter therapy, the need for patient-specific dosimetry may arise if a large variability in biodistribution, normal tissue toxicity or efficacy is anticipated. Patient-specificity may be accomplished at the level of pharmacokinetics, anatomy/tumor-geometry or both. At the first level, information regarding the biodistribution of a particular radiolabeled agent is obtained and used to determine the maximum activity that may be administered for treatment. The classical example of this is radioiodine therapy for thyroid cancer. In radioiodine therapy, the therapy dose is preceded by a tracer dose of I-131-iodide which is used to measure patient kinetics by imaging and whole-body counting. Absorbed dose estimates obtained from these data are used to constrain the therapy dose to meet safety criteria established in a previously performed dose-response study. The most ambitious approach to patient-specific dosimetry, requires a three-dimensional set of images representing radionuclide distribution (SPECT or PET) and a corresponding set of registered images representing anatomy (CT or MRI). The spatial distribution of absorbed dose or dose-rate may then be obtained by convolution of a point-kernel with the radioactivity distribution or by Monte Carlo calculation. The spatial absorbed dose or dose-rate distribution may be represented as a set of images, as isodose contours, or as dose-volume histograms. The 3-D Monte Carlo approach is, in principle, the most patient-specific; it accounts for patient anatomy and tumor geometry as well as for the spatial distribution of radioactivity. It is also, however, the most logistically and technically demanding. Patients are required to undergo CT or MRI and at least one

  7. Low-level measurements by liquid scintillation counting

    International Nuclear Information System (INIS)

    Schoenhofer, F.

    1991-01-01

    Liquid scintillation counting has become a convenient tool for analysis of many beta- and alpha-emitters even in ultra low-level concentration ranges. Extremely low background is achieved in a commercially available counter by an active shielding and heavy lead shielding. Thus special time saving radiochemical separation processes could be designed. Extremely simple sample preparation techniques can be used. Counting time can be reduced and sample throughput enhanced. Also precision can be enhanced. From the author's research, several applications are discussed. They include: tritium in water without enrichment, tritium in urine (excretion analysis), carbon-14 in samples like alcohol or vinegar, Rn-222 in water and air, even gaseous Kr-85. A simple and fast method for Sr-90 in environmental samples and food has been developed and the Ra-226-concentration in water can be measured as low as 30 mBq/l without any chemical separation or enrichment. The instrument has been used successfully for screening purposes after the Chernobyl accident as well as for monitoring groundwater after a large scale contamination in Lower Austria. Using a 'gross-beta-measurement' effluents from a nuclear installation are monitored, clearly showing advantages over traditional methods. α-β-discrimination reduces the background for alpha emitters to practically zero. Examples from the determination of Ra-226 in water are shown

  8. Gamma flux responsive self-powered detector with a tubular emitter

    International Nuclear Information System (INIS)

    Goldstein, N.P.; Todt, W.H.

    1982-01-01

    A gamma-sensitive flux detector comprises tubular emitter, an insulating core within the emitter and an insulating layer about the emitter, and a tubular conductive collector electrode about the insulating layer. The emitter material may be platinum, lead, bismuth, tantalum, tungsten; platinum preferred

  9. Electromagnetic compatibility of implantable neurostimulators to RFID emitters.

    Science.gov (United States)

    Pantchenko, Oxana S; Seidman, Seth J; Guag, Joshua W; Witters, Donald M; Sponberg, Curt L

    2011-06-09

    The objective of this study is to investigate electromagnetic compatibility (EMC) of implantable neurostimulators with the emissions from radio frequency identification (RFID) emitters. Six active implantable neurostimulators with lead systems were tested for susceptibility to electromagnetic fields generated by 22 RFID emitters. These medical devices have been approved for marketing in the U.S. for a number of intended uses that include: epilepsy, depression, incontinence, Parkinsonian tremor and pain relief. Each RFID emitter had one of the following carrier frequencies: 125 kHz, 134 kHz, 13.56 MHz, 433 MHz, 915 MHz and 2.45 GHz. The test results showed the output of one of the implantable neurostimulators was inhibited by 134 kHz RFID emitter at separation distances of 10 cm or less. The output of the same implantable neurostimulator was also inhibited by another 134 kHz RFID emitter at separation distances of 10 cm or less and also showed inconsistent pulsing rate at a separation distance of 15 cm. Both effects occurred during and lasted through out the duration of the exposure. The clinical significance of the effects was assessed by a clinician at the U.S. Food and Drug Administration. The effects were determined to be clinically significant only if they occurred for extended period of time. There were no observed effects from the other 5 implantable neurostimulators or during exposures from other RFID emitters.

  10. Electromagnetic compatibility of implantable neurostimulators to RFID emitters

    Directory of Open Access Journals (Sweden)

    Guag Joshua W

    2011-06-01

    Full Text Available Abstract Background The objective of this study is to investigate electromagnetic compatibility (EMC of implantable neurostimulators with the emissions from radio frequency identification (RFID emitters. Methods Six active implantable neurostimulators with lead systems were tested for susceptibility to electromagnetic fields generated by 22 RFID emitters. These medical devices have been approved for marketing in the U.S. for a number of intended uses that include: epilepsy, depression, incontinence, Parkinsonian tremor and pain relief. Each RFID emitter had one of the following carrier frequencies: 125 kHz, 134 kHz, 13.56 MHz, 433 MHz, 915 MHz and 2.45 GHz Results The test results showed the output of one of the implantable neurostimulators was inhibited by 134 kHz RFID emitter at separation distances of 10 cm or less. The output of the same implantable neurostimulator was also inhibited by another 134 kHz RFID emitter at separation distances of 10 cm or less and also showed inconsistent pulsing rate at a separation distance of 15 cm. Both effects occurred during and lasted through out the duration of the exposure. Conclusions The clinical significance of the effects was assessed by a clinician at the U.S. Food and Drug Administration. The effects were determined to be clinically significant only if they occurred for extended period of time. There were no observed effects from the other 5 implantable neurostimulators or during exposures from other RFID emitters.

  11. Measured emittance dependence on injection method in laser plasma accelerators

    Science.gov (United States)

    Barber, Samuel; van Tilborg, Jeroen; Schroeder, Carl; Lehe, Remi; Tsai, Hai-En; Swanson, Kelly; Steinke, Sven; Nakamura, Kei; Geddes, Cameron; Benedetti, Carlo; Esarey, Eric; Leemans, Wim

    2017-10-01

    The success of many laser plasma accelerator (LPA) based applications relies on the ability to produce electron beams with excellent 6D brightness, where brightness is defined as the ratio of charge to the product of the three normalized emittances. As such, parametric studies of the emittance of LPA generated electron beams are essential. Profiting from a stable and tunable LPA setup, combined with a carefully designed single-shot transverse emittance diagnostic, we present a direct comparison of charge dependent emittance measurements of electron beams generated by two different injection mechanisms: ionization injection and shock induced density down-ramp injection. Notably, the measurements reveal that ionization injection results in significantly higher emittance. With the down-ramp injection configuration, emittances less than 1 micron at spectral charge densities up to 2 pC/MeV were measured. This work was supported by the U.S. DOE under Contract No. DE-AC02-05CH11231, by the NSF under Grant No. PHY-1415596, by the U.S. DOE NNSA, DNN R&D (NA22), and by the Gordon and Betty Moore Foundation under Grant ID GBMF4898.

  12. Experimental investigation of thermal emittance components of copper photocathode

    Directory of Open Access Journals (Sweden)

    H. J. Qian

    2012-04-01

    Full Text Available With progress of photoinjector technology, thermal emittance has become the primary limitation of electron beam brightness. Extensive efforts have been devoted to study thermal emittance, but experiment results differ between research groups and few can be well interpreted. Besides the ambiguity of photoemission mechanism, variations of cathode surface conditions during cathode preparation, such as work function, field enhancement factor, and surface roughness, will cause thermal emittance differences. In this paper, we report an experimental study of electric field dependence of copper cathode quantum efficiency (QE and thermal emittance in a radio frequency (rf gun, through which in situ cathode surface parameters and thermal emittance contributions from photon energy, Schottky effect, and surface roughness are extracted. It is found the QE of a copper cathode illuminated by a 266 nm UV laser increased substantially to 1.5×10^{-4} after cathode cleaning during rf conditioning, and a copper work function of 4.16 eV, which is much lower than nominal value (4.65 eV, was measured. Experimental results also show a thermal emittance growth as much as 0.92  mm mrad/mm at 50  MV/m due to the cathode surface roughness effect, which is consistent with cathode surface morphology measurements.

  13. Design and fabrication of carbon fibers with needle-like nano-HA coating to reinforce granular nano-HA composites.

    Science.gov (United States)

    Wang, Xudong; Zhao, Xueni; Zhang, Li; Wang, Wanying; Zhang, Jing; He, Fuzhen; Yang, Jianjun

    2017-08-01

    Carbon fibers (CFs) with needle-like nano-hydroxyapatite (nHA) coating were first used as reinforcing materials named nHA-CFs to improve the mechanical properties of pure HA. A powder mixture containing nHA-CFs and granular nano-HA (gHA) was directly sintered by hot pressing at appropriate sintering pressure and temperature. A three-phase nHA-CFs/gHA composite was designed, fabricated, and used as an artificial bone. Results show that the bending strengths of the nHA-CFs/gHA composite are approximately 41.1% and 59.2% higher than those of CFs/gHA composite and pure HA, respectively. The possible reinforcing mechanism of nHA-CFs in the composite is also proposed at the end. When nHA-CFs are applied for preparation of nHA-CFs/gHA composites, the internal stress on its phase boundary with gHA matrix generated during cooling of sintered is significantly reduced due to the presence of the nHA coatings. It infers that nHA coatings on CFs might act as a bridge to control the forming of interfacial gaps between the gHA matrix and the CFs effectively. Our work provides additional insights into the feasibility of nHA-CFs/gHA composites as load-bearing implant materials in clinical applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Decoupling Intensity Radiated by the Emitter in Distance Estimation from Camera to IR Emitter

    Directory of Open Access Journals (Sweden)

    Carlos Andrés Luna Vázquez

    2013-05-01

    Full Text Available Various models using radiometric approach have been proposed to solve the problem of estimating the distance between a camera and an infrared emitter diode (IRED. They depend directly on the radiant intensity of the emitter, set by the IRED bias current. As is known, this current presents a drift with temperature, which will be transferred to the distance estimation method. This paper proposes an alternative approach to remove temperature drift in the distance estimation method by eliminating the dependence on radiant intensity. The main aim was to use the relative accumulated energy together with other defined models, such as the zeroth-frequency component of the FFT of the IRED image and the standard deviation of pixel gray level intensities in the region of interest containing the IRED image. By using the abovementioned models, an expression free of IRED radiant intensity was obtained. Furthermore, the final model permitted simultaneous estimation of the distance between the IRED and the camera and the IRED orientation angle. The alternative presented in this paper gave a 3% maximum relative error over a range of distances up to 3 m.

  15. Production of positron emitters of metallic elements to study plant uptake and distribution

    International Nuclear Information System (INIS)

    Watanabe, S.; Ishioka, N.S.; Sekine, T.; Osa, A.; Koizumi, M.; Kiyomiya, S.; Nakanishi, H.; Mori, S.

    2001-01-01

    The metallic positron emitters 52 Mn, 52 Fe and 62 Zn, the elements of which are essential nutrients for plants as well as for animals, have been produced for a new tracer method in plant physiology. The tracer method utilizes the detection of annihilation γ-rays, like PET in nuclear medicine, to obtain two-dimensional images on a plant as well as to obtain radioactivity counts at specified points in a plant; this method allows us to observe the tracer movement in a living plant without touching the test plant. The previously reported methods of radiochemical separation of these metallic positron emitters from targets were partly modified from the view of their use in plant physiology. Radionuclidic impurities remaining in the final solutions were examined by γ-ray spectrometry, and their influences on the above-mentioned measurements are discussed. From the experiments on a barley plant, the speeds of 52 Mn 2+ ion and 52 Fe 3+ - mugineic-acid complex have been obtained for the first time to be 0.2 cm/min and 1.0 cm/min, respectively. (orig.)

  16. Barium Depletion in Hollow Cathode Emitters

    Science.gov (United States)

    Polk, James E.; Capece, Angela M.; Mikellides, Ioannis G.; Katz, Ira

    2009-01-01

    The effect of tungsten erosion, transport and redeposition on the operation of dispenser hollow cathodes was investigated in detailed examinations of the discharge cathode inserts from an 8200 hour and a 30,352 hour ion engine wear test. Erosion and subsequent re-deposition of tungsten in the electron emission zone at the downstream end of the insert reduces the porosity of the tungsten matrix, preventing the ow of barium from the interior. This inhibits the interfacial reactions of the barium-calcium-aluminate impregnant with the tungsten in the pores. A numerical model of barium transport in the internal xenon discharge plasma shows that the barium required to reduce the work function in the emission zone can be supplied from upstream through the gas phase. Barium that flows out of the pores of the tungsten insert is rapidly ionized in the xenon discharge and pushed back to the emitter surface by the electric field and drag from the xenon ion flow. This barium ion flux is sufficient to maintain a barium surface coverage at the downstream end greater than 0.6, even if local barium production at that point is inhibited by tungsten deposits. The model also shows that the neutral barium pressure exceeds the equilibrium vapor pressure of the impregnant decomposition reaction over much of the insert length, so the reactions are suppressed. Only a small region upstream of the zone blocked by tungsten deposits is active and supplies the required barium. These results indicate that hollow cathode failure models based on barium depletion rates in vacuum dispenser cathodes are very conservative.

  17. Silicon Carbide Emitter Turn-Off Thyristor

    Directory of Open Access Journals (Sweden)

    Jun Wang

    2008-01-01

    Full Text Available A novel MOS-controlled SiC thyristor device, the SiC emitter turn-off thyristor (ETO is a promising technology for future high-voltage switching applications because it integrates the excellent current conduction capability of a SiC thyristor with a simple MOS-control interface. Through unity-gain turn-off, the SiC ETO also achieves excellent Safe Operation Area (SOA and faster switching speeds than silicon ETOs. The world's first 4.5-kV SiC ETO prototype shows a forward voltage drop of 4.26 V at 26.5 A/cm2 current density at room and elevated temperatures. Tested in an inductive circuit with a 2.5 kV DC link voltage and a 9.56-A load current, the SiC ETO shows a fast turn-off time of 1.63 microseconds and a low 9.88 mJ turn-off energy. The low switching loss indicates that the SiC ETO could operate at about 4 kHz if 100 W/cm2 conduction and the 100 W/cm2 turn-off losses can be removed by the thermal management system. This frequency capability is about 4 times higher than 4.5-kV-class silicon power devices. The preliminary demonstration shows that the SiC ETO is a promising candidate for high-frequency, high-voltage power conversion applications, and additional developments to optimize the device for higher voltage (>5 kV and higher frequency (10 kHz are needed.

  18. High-precision half-life measurements for the superallowed Fermi β+ emitter 14O

    Science.gov (United States)

    Laffoley, A. T.; Svensson, C. E.; Andreoiu, C.; Austin, R. A. E.; Ball, G. C.; Blank, B.; Bouzomita, H.; Cross, D. S.; Diaz Varela, A.; Dunlop, R.; Finlay, P.; Garnsworthy, A. B.; Garrett, P. E.; Giovinazzo, J.; Grinyer, G. F.; Hackman, G.; Hadinia, B.; Jamieson, D. S.; Ketelhut, S.; Leach, K. G.; Leslie, J. R.; Tardiff, E.; Thomas, J. C.; Unsworth, C.

    2013-07-01

    The half-life of the superallowed Fermi β+ emitter 14O has been determined via simultaneous direct β and γ counting experiments at TRIUMF's Isotope Separator and Accelerator (ISAC) facility. A γ-ray counting measurement was performed by detecting the 2312.6-keV γ rays emitted from an excited state of the daughter 14N following the implantation of samples at the center of the 8π γ-ray spectrometer, a spherical array of 20 high-purity germanium (HPGe) detectors. A simultaneous β counting experiment was performed using a fast plastic scintillator positioned behind the implantation site with a solid angle coverage of ˜20%. The results, T1/2(β)=70.610±0.030s and T1/2(γ)=70.632±0.094s, form a consistent set and, together with eight previous measurements, establish a new average for the 14O half-life of T1/2=70.619±0.011s with a reduced χ2 of 0.99.

  19. High-Precision Half-Life Measurements for the Superallowed Fermi β+ Emitters 14O and 18Ne

    Science.gov (United States)

    Laffoley, A. T.; Andreoiu, C.; Austin, R. A. E.; Ball, G. C.; Bender, P. C.; Bidaman, H.; Bildstein, V.; Blank, B.; Bouzomita, H.; Cross, D. S.; Deng, G.; Diaz Varela, A.; Dunlop, M. R.; Dunlop, R.; Finlay, P.; Garnsworthy, A. B.; Garrett, P.; Giovinazzo, J.; Grinyer, G. F.; Grinyer, J.; Hadinia, B.; Jamieson, D. S.; Jigmeddorj, B.; Ketelhut, S.; Kisliuk, D.; Leach, K. G.; Leslie, J. R.; MacLean, A.; Miller, D.; Mills, B.; Moukaddam, M.; Radich, A. J.; Rajabali, M. M.; Rand, E. T.; Svensson, C. E.; Tardiff, E.; Thomas, J. C.; Turko, J.; Voss, P.; Unsworth, C.

    High-precision half-life measurements, at the level of ±0.04%, for the superallowed Fermi emitters 14O and 18Ne have been performed at TRIUMF's Isotope Separator and Accelerator facility. Using 3 independent detector systems, a gas-proportional counter, a fast plastic scintillator, and a high-purity germanium array, a series of direct β and γ counting measurements were performed for each of the isotopes. In the case of 14O, these measurements were made to help resolve an existing discrepancy between detection methods, whereas for 18Ne the half-life precision has been improved in anticipation of forthcoming high-precision branching ratio measurements.

  20. A-Ha. Drum'n'bassi supernimi FABIO

    Index Scriptorium Estoniae

    2002-01-01

    7.sept. annab norra menukaim popansambel A-Ha Tallinnas Lauluväljakul kontserdi, kus presenteerib ka oma viimast albumit "Lifelines". 14. sept.tuleb drum'n'bassi spetsialist Fabio Tallinna üritusele Circulation

  1. Adhesive strength of hydroxyl apatite(HA coating and biomechanics behavior of HA-coated prosthesis:an experimental study

    Directory of Open Access Journals (Sweden)

    Tian-yang ZHANG

    2011-05-01

    Full Text Available Objective To explore the influence of adhesive strength of hydroxyapatite(HA coating on the post-implantation stability of HA-coated prosthesis.Methods The adhesive strength and biomechanics behavior of HA coating were studied by histopathological observation,material parameters and biomechanical testing,the titanium(Ti-coated prosthesis was employed as control.Results Scratch test showed that the adhesive strength of HA coating was significantly lower than that of Ti coating(P < 0.01.Histopathological examination and bone morphometry showed that,at the early stage of prosthesis implantation,the bony growth around HA-coated prosthesis was significantly higher than that around Ti-coated prosthesis(P < 0.01,but the ultimate shear strength of HA-coated prosthesis was much lower than that of Ti-coated prosthesis(P < 0.01.After the push-out test with prosthesis,histopathological observation showed that there were accumulations of clump-and strip-like granular residues on the surface of bones that newly grew around the HA-coated prosthesis,and surface energy-dispersive X-ray spectroscopy(EDX analysis also confirmed that the shear stress induced HA decohesion from the substrate of prosthesis.Conclusions Although HA coating showed a satisfactory effect on early bone formation and prosthetic stability,due to the deficiencies of adhesive strength,the early stability of prosthesis may be gradually destroyed by the shear loads of human body and coating degradation.

  2. CalCOFI Egg Counts

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish egg counts and standardized counts for eggs captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets], and...

  3. Radon Daughters Background Reduction in Alpha Particles Counting System

    International Nuclear Information System (INIS)

    Dadon, S. S.; Pelled, O.; Orion, I.

    2014-01-01

    The ABPC method is using a serially occurring events of the beta decay of the 214Bi fallow by alpha decay of the 214Po that take place almost simultaneously to detect the Pseudo Coincidence Event (PCE) from the RDP, and to subtract them from the gross alpha counts. 267 This work showed that it is possible to improve the efficiency of RDP background reduction, including subtracting the 218Po contribution by using the ABPC method based on a single solid state silicon PIPS detector. False counts percentage obtained at the output of the PCE circuit were smaller than 0.1%. The results show that the PCE circuit was not influenced by non RDP alpha emitters. The PCE system did not reduce the non PCE of the 218Po. After 20 minutes the 218Po was strongly decayed, and its contribution became negligible. In order to overcome this disadvantage, a mathematical matching calculations for the 214Po and the 218Po decay equations were employed, and a constant ratio of the APo214(0) / APo218(0) was obtained. This ratio can be used to estimate the count rate of the 218Po at the first 20 minutes, and to subtract it from the total count rate in order to obtain correct RDP reduction

  4. Counting statistics in radioactivity measurements

    International Nuclear Information System (INIS)

    Martin, J.

    1975-01-01

    The application of statistical methods to radioactivity measurement problems is analyzed in several chapters devoted successively to: the statistical nature of radioactivity counts; the application to radioactive counting of two theoretical probability distributions, Poisson's distribution law and the Laplace-Gauss law; true counting laws; corrections related to the nature of the apparatus; statistical techniques in gamma spectrometry [fr

  5. Do your syringes count?

    International Nuclear Information System (INIS)

    Brewster, K.

    2002-01-01

    Full text: This study was designed to investigate anecdotal evidence that residual Sestamibi (MIBI) activity vaned in certain situations. For rest studies different brands of syringes were tested to see if the residuals varied. The period of time MIBI doses remained in the syringe between dispensing and injection was also considered as a possible source of increased residual counts. Stress Mibi syringe residual activities were measured to assess if the method of stress test affected residual activity. MIBI was reconstituted using 13 Gbq of Technetium in 3mls of normal saline then boiled for 10 minutes. Doses were dispensed according to department protocol and injected via cannula. Residual syringes were collected for three syringe types. In each case the barrel and plunger were measured separately. As the syringe is flushed during the exercise stress test and not the pharmacological stress test the chosen method was recorded. No relationship was demonstrated between the time MIBI remained in a syringe prior to injection and residual activity. Residual activity was not affected by method of stress test used. Actual injected activity can be calculated if the amount of activity remaining in the syringe post injection is known. Imaging time can be adjusted for residual activity to optimise count statistics. Preliminary results in this study indicate there is no difference in residual activity between syringe brands.Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  6. Liquid scintillation alpha counting and spectrometry and its application to bone and tissue samples

    International Nuclear Information System (INIS)

    McDowell, W.J.; Weiss, J.F.

    1976-01-01

    Three methods for determination of alpha-emitting nuclides using liquid scintillation counting are compared, and the pertinent literature is reviewed. Data showing the application of each method to the measurement of plutonium concentration in tissue and bone samples are presented. Counting with a commercial beta-liquid scintillation counter and an aqueous-phase-accepting scintillator is shown to be accurate only in cases where the alpha activity is high (several hundred counts/min or more), only gross alpha counting is desired, and beta-gamma emitters are known to be absent from the sample or present at low levels compared with the alpha activity. Counting with the same equipment and an aqueous immiscible scintillator containing an extractant for the nuclide of interest (extractive scintillator) is shown to allow better control of alpha peak shift due to quenching, a significant reduction of beta-gamma interference, and, usually, a low background. The desirability of using a multichannel pulse-height analyzer in the above two counting methods is stressed. The use of equipment and procedures designed for alpha liquid scintillation counting is shown to allow alpha spectrometry with an energy resolution capability of 200 to 300 keV full-peak-width-at-half-peak-height and a background of 0.3 to 1.0 counts/min, or as low as 0.01 counts/min if pulse-shape discrimination methods are used. Methods for preparing animal bone and tissue samples for assay are described

  7. Transverse emittance measurement and preservation at the LHC

    Energy Technology Data Exchange (ETDEWEB)

    Kuhn, Maria

    2016-06-20

    The Large Hadron Collider (LHC) at CERN is a high energy storage ring that provides proton and heavy ion collisions to study fundamental particle physics. The luminosity production is closely linked to emittance preservation in the accelerator. The transverse emittance is the phase space density of the beam and should be conserved when the particle beam is transformed through the accelerator. Perturbing effects, however, can lead to emittance increase and hence luminosity degradation. Measuring the emittance growth is a complex task with high intensity beams and changing energies. The machine optics and the transverse beam size have to be measured as accurately as possible. Beta function measurements with k-modulation are discussed. With this method the quadrupole focussing strength is varied and the resulting tune change is traced to determine the beta function at the quadrupole. A new k-modulation measurement tool was developed for the LHC. The fully automatic and online measurement system takes constraints of various systems such as tune measurement precision and powering limitations of the LHC superconducting circuits into account. With sinusoidal k-modulation record low beta function measurement uncertainties in the LHC have been reached. 2015 LHC beta function and β*, which is the beta function at the collision point, measurements with k-modulation will be presented. Wire scanners and synchrotron light monitors are presently used in the LHC to measure the transverse beam size. Accuracy and limitations of the LHC transverse profile monitors are discussed. During the 2012 LHC proton run it was found that wire scanner photomultiplier saturation added significant uncertainty on all measurements. A large discrepancy between emittances from wire scanners and luminosity was discovered but not solved. During Long Shutdown 1 the wire scanner system was upgraded with new photomultipliers. A thorough study of LHC wire scanner measurement precision in 2015 is presented

  8. Osteoblast interaction with laser cladded HA and SiO2-HA coatings on Ti-6Al-4V

    International Nuclear Information System (INIS)

    Yang Yuling; Serpersu, Kaan; He Wei; Paital, Sameer R.; Dahotre, Narendra B.

    2011-01-01

    In order to improve the bioactivity and biocompatibility of titanium endosseous implants, the morphology and composition of the surfaces were modified. Polished Ti-6Al-4V substrates were coated by a laser cladding process with different precursors: 100 wt.% HA and 25 wt.% SiO 2 -HA. X-ray diffraction of the laser processed samples showed the presence of CaTiO 3 , Ca 3 (PO 4 ) 2 , and Ca 2 SiO 4 phases within the coatings. From in vitro studies, it was observed that compared to the unmodified substrate all laser cladded samples presented improved cellular interactions and bioactivity. The samples processed with 25 wt.% SiO 2 -HA precursor showed a significantly higher HA precipitation after immersion in simulated body fluid than 100 wt.% HA precursor and titanium substrates. The in vitro biocompatibility of the laser cladded coatings and titanium substrate was investigated by culturing of mouse MC3T3-E1 pre-osteoblast cell line and analyzing the cell viability, cell proliferation, and cell morphology. A significantly higher cell attachment and proliferation rate were observed for both laser cladded 100 wt.% HA and 25 wt.% SiO 2 -HA samples. Compared to 100 wt.% HA sample, 25 wt.% SiO 2 -HA samples presented a slightly improved cellular interaction due to the addition of SiO 2 . The staining of the actin filaments showed that the laser cladded samples induced a normal cytoskeleton and well-developed focal adhesion contacts. Scanning electron microscopic image of the cell cultured samples revealed better cell attachment and spreading for 25 wt.% SiO 2 -HA and 100 wt.% HA coatings than titanium substrate. These results suggest that the laser cladding process improves the bioactivity and biocompatibility of titanium. The observed biological improvements are mainly due to the coating induced changes in surface chemistry and surface morphology. Highlights: → Laser cladding of Ti alloys with bioceramics creates new phases. → Laser cladded samples with SiO 2 -doped

  9. Osteoblast interaction with laser cladded HA and SiO{sub 2}-HA coatings on Ti-6Al-4V

    Energy Technology Data Exchange (ETDEWEB)

    Yang Yuling [Department of Physics, Northeastern University, Shenyang 110004 (China); Department of Materials Science and Engineering, University of Tennessee, Knoxville, TN 37996 (United States); Serpersu, Kaan [Department of Materials Science and Engineering, University of Tennessee, Knoxville, TN 37996 (United States); He Wei, E-mail: whe5@utk.edu [Department of Materials Science and Engineering, University of Tennessee, Knoxville, TN 37996 (United States); Department of Mechanical, Aerospace and Biomedical Engineering, University of Tennessee, Knoxville, TN 37996 (United States); Paital, Sameer R. [Department of Materials Science and Engineering, University of Tennessee, Knoxville, TN 37996 (United States); Dahotre, Narendra B. [Department of Materials Science and Engineering, University of North Texas, Denton, TX 76207 (United States)

    2011-12-01

    In order to improve the bioactivity and biocompatibility of titanium endosseous implants, the morphology and composition of the surfaces were modified. Polished Ti-6Al-4V substrates were coated by a laser cladding process with different precursors: 100 wt.% HA and 25 wt.% SiO{sub 2}-HA. X-ray diffraction of the laser processed samples showed the presence of CaTiO{sub 3}, Ca{sub 3}(PO{sub 4}){sub 2}, and Ca{sub 2}SiO{sub 4} phases within the coatings. From in vitro studies, it was observed that compared to the unmodified substrate all laser cladded samples presented improved cellular interactions and bioactivity. The samples processed with 25 wt.% SiO{sub 2}-HA precursor showed a significantly higher HA precipitation after immersion in simulated body fluid than 100 wt.% HA precursor and titanium substrates. The in vitro biocompatibility of the laser cladded coatings and titanium substrate was investigated by culturing of mouse MC3T3-E1 pre-osteoblast cell line and analyzing the cell viability, cell proliferation, and cell morphology. A significantly higher cell attachment and proliferation rate were observed for both laser cladded 100 wt.% HA and 25 wt.% SiO{sub 2}-HA samples. Compared to 100 wt.% HA sample, 25 wt.% SiO{sub 2}-HA samples presented a slightly improved cellular interaction due to the addition of SiO{sub 2}. The staining of the actin filaments showed that the laser cladded samples induced a normal cytoskeleton and well-developed focal adhesion contacts. Scanning electron microscopic image of the cell cultured samples revealed better cell attachment and spreading for 25 wt.% SiO{sub 2}-HA and 100 wt.% HA coatings than titanium substrate. These results suggest that the laser cladding process improves the bioactivity and biocompatibility of titanium. The observed biological improvements are mainly due to the coating induced changes in surface chemistry and surface morphology. Highlights: {yields} Laser cladding of Ti alloys with bioceramics creates new

  10. Transverse emittance dilution due to coupler kicks in linear accelerators

    Directory of Open Access Journals (Sweden)

    Brandon Buckley

    2007-11-01

    Full Text Available One of the main concerns in the design of low emittance linear accelerators (linacs is the preservation of beam emittance. Here we discuss one possible source of emittance dilution, the coupler kick, due to transverse electromagnetic fields in the accelerating cavities of the linac caused by the power coupler geometry. In addition to emittance growth, the coupler kick also produces orbit distortions. It is common wisdom that emittance growth from coupler kicks can be strongly reduced by using two couplers per cavity mounted opposite each other or by having the couplers of successive cavities alternate from above to below the beam pipe so as to cancel each individual kick. While this is correct, including two couplers per cavity or alternating the coupler location requires large technical changes and increased cost for superconducting cryomodules where cryogenic pipes are arranged parallel to a string of several cavities. We therefore analyze consequences of alternate coupler placements. We show here that alternating the coupler location from above to below compensates the emittance growth as well as the orbit distortions. For sufficiently large Q values, alternating the coupler location from before to after the cavity leads to a cancellation of the orbit distortion but not of the emittance growth, whereas alternating the coupler location from before and above to behind and below the cavity cancels the emittance growth but not the orbit distortion. We show that cancellations hold for sufficiently large Q values. These compensations hold even when each cavity is individually detuned, e.g., by microphonics. Another effective method for reducing coupler kicks that is studied is the optimization of the phase of the coupler kick so as to minimize the effects on emittance from each coupler. This technique is independent of the coupler geometry but relies on operating on crest. A final technique studied is symmetrization of the cavity geometry in the

  11. Determination of plutonium-241 by liquid scintillation counting method and its application to environmental samples

    International Nuclear Information System (INIS)

    Watanabe, Miki; Amano, Hikaru

    1997-03-01

    Radionuclides are usually measured by gross counting mode in liquid scintillator counting (LSC) which measures both α and β pulses. This method can easily measure radioactivities, but its background counting is high. Recently reported α-β pulse shape discrimination method (α-β PSD method) in LSC which distinguishes α pulses from β pulses, shows low background counting, so it makes the detection limit lower. The aim of this research is to develop the best method for the determination of 241 Pu which is β-emitter, and Pu isotopes of α-emitters which have long half-lives and stay long in animal body. In this research, two LSC machines was carried out in different scintillators, vial volumes, measurement modes and so on. The following things were found. 1. The liquid scintillator based on naphthalene is proved to be the best separator of α-ray from β-ray, because it acts quickly in energy translation procedure between solvent and aromatic compounds. 2. α-β PSD method makes the background counting rate ten times lower than usual method. It makes the measurement performance better. 3. It is possible to determine 241 Pu in environmental samples around Chernobyl by the combination of LSC and radiochemical separation methods. (author)

  12. Emittance growth and tune spectra at PETRA III

    International Nuclear Information System (INIS)

    Wanzenberg, R.

    2011-08-01

    At DESY the PETRA ring has been converted into a synchrotron radiation facility, called PETRA III. 20 damping wigglers have been installed to achieve an emittance of 1 nm. The commissioning with beam started in April 2009 and user runs have been started in 2010. The design current is 100 mA and the bunch to bunch distance is 8 ns for one particular filling pattern with 960 bunches. At a current of about 50 mA a strong vertical emittance increase has been observed. During machine studies it was found that the emittance increase depends strongly on the bunch filling pattern. For the user operation a filling scheme has been found which mitigates the increase of the vertical emittance. In August 2010 PETRA III has been operated without damping wigglers for one week. The vertical emittance growth was not significantly smaller without wigglers. Furthermore tune spectra at PETRA III show characteristic lines which have been observed at other storage rings in the connection with electron clouds. Measurements at PETRA III are presented for different bunch filling patterns and with and without wiggler magnets. (orig.)

  13. Measurement of transverse emittance in the Fermilab booster

    Energy Technology Data Exchange (ETDEWEB)

    Graves, William Sproull [Wisconsin U., Madison

    1994-01-01

    A new beam profile monitor has been built and installed in the Fermilab Booster synchrotron. It nondestructively measures the beam's vertical density distribution on a fast turn-by-turn basis. This enables one to measure the beam's transverse emittance and to observe emittance growth as it occurs. For high intensities (>2 times 10^{12 } protons), the normalized 95% emittance was observed to grow from 6pi mm-mrad at injection to 16pi mm-mrad at extraction. The initial (<5 msec) emittance growth and beam losses are shown to be caused by the space charge tune shift onto integer and 1/2 integer resonance lines. The growth near injection accounts for approximately 40% of the observed emittance increase throughout the acceleration cycle. The remaining 60% is due to two factors: slow linear growth due to betatron-motion driven by noise in the rf system; and faster growth after the transition energy that is caused by coupling of the longitudinal beam motion into the transverse planes.

  14. Transverse emittance growth in staged laser-wakefield acceleration

    Directory of Open Access Journals (Sweden)

    T. Mehrling

    2012-11-01

    Full Text Available We present a study on the emittance evolution of electron bunches, externally injected into laser-driven plasma waves using the three-dimensional particle-in-cell (PIC code OSIRIS. Results show order-of-magnitude transverse emittance growth during the injection process, if the electron bunch is not matched to its intrinsic betatron motion inside the wakefield. This behavior is supported by analytic theory reproducing the simulation data to a percent level. The length over which the full emittance growth develops is found to be less than or comparable to the typical dimension of a single plasma module in current multistage designs. In addition, the analytic theory enables the quantitative prediction of emittance degradation in two consecutive accelerators coupled by free-drift sections, excluding this as a scheme for effective emittance-growth suppression, and thus suggests the necessity of beam-matching sections between acceleration stages with fundamental implications on the overall design of staged laser-wakefield accelerators.

  15. Graphene field emitters: A review of fabrication, characterization and properties

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Leifeng, E-mail: chlf@hdu.edu.cn [College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou 310018 (China); State Key Laboratory of Silicon Materials, Zhejiang University, Hangzhou 310027 (China); Yu, Hu; Zhong, Jiasong; Song, Lihui [College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou 310018 (China); Wu, Jun, E-mail: wujun@hdu.edu.cn [Institute of Electron Device & Application, Hangzhou Dianzi University, Hangzhou, Zhejiang 310018 (China); Su, Weitao [College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou 310018 (China)

    2017-06-15

    Highlights: • The preparation, characterization and field emission properties for Gs are reviewed. • The review provides an updated progress on design and construction of Gs field emitters. • The review offers fundamental insights into understanding and design of Gs emitters. • The review can broach the subject and inspire readers in field of Gs based emitters. - Abstract: Graphenes are beneficial to electrons field emission due to its high aspect ratio, high carrier density, the larger carrier mobility, excellent electrical and thermal conductivity, excellent mechanical strength and chemical stability. In recent years, graphene or reduced oxide graphene field emitters have been successfully constructed by various methods such as chemical vapor deposition, chemical exfoliation, electrophoretic deposition, screen-printing and chemical synthesis methods. Graphene emitters are tried to construct in distribution with some angles or vertical orientation with respect to the substrate surface. The vertical alignment of graphene sheets or edges arrays can facilitate efficient electron emission from the atomically thick sheets. Therefore they have even more a low turn-on and threshold-field electronic field, high field enhancement factor, high current stability and high luminance. In this review, we shortly survey and discuss recent research progress in graphene field emission properties with particular an emphasis on their preparing method, characterization and applications in devices especially for vertical graphene and single layer graphene, also including their challenges and future prospects.

  16. Emittance measurements in Grumman 1 MeV beamline

    International Nuclear Information System (INIS)

    Debiak, T.; Gammel, G.; Melnychuk, S.

    1992-01-01

    The emittance of a 30 keV H - beam has been measured with an Allison type electrostatic analyser at two positions separated by 85 cm along the Grumman 1 MeV beamline LEBT at low currents (about 4 mA, no Cs 2 O additive in the source) and at higher currents (10-15 mA, with Cs 2 O additive in the source). No emittance growth was observed between the two positions, but, at the higher current level, the emittance was about 60% higher than at the low current level (Σ n ,rms = .0045 π cm-mrad vs. 0070 π cm-mrad). Argon was then introduced up to a partial pressure of 4x10 -5 torr, and the emittance decreased back to a range corresponding to that found at the lower currents. However, beam noise was observed at the downstream position, and there is evidence for a small amount of emittance growth (<20%) between the two positions

  17. Fitting of alpha-efficiency versus quenching parameter by exponential functions in liquid scintillation counting

    International Nuclear Information System (INIS)

    Sosa, M.; Manjón, G.; Mantero, J.; García-Tenorio, R.

    2014-01-01

    The objective of this work is to propose an exponential fit for the low alpha-counting efficiency as a function of a sample quenching parameter using a Quantulus liquid scintillation counter. The sample quenching parameter in a Quantulus is the Spectral Quench Parameter of the External Standard (SQP(E)), which is defined as the number of channel under which lies the 99% of Compton spectrum generated by a gamma emitter ( 152 Eu). Although in the literature one usually finds a polynomial fitting of the alpha counting efficiency, it is shown here that an exponential function is a better description. - Highlights: • We have studied the quenching in alpha measurement by liquid scintillation counting. • We have reviewed typical fitting of alpha counting efficiency versus quenching parameter. • Exponential fitting of data is proposed as better fitting. • We consider exponential fitting has a physical basis

  18. Fitting of alpha-efficiency versus quenching parameter by exponential functions in liquid scintillation counting

    Energy Technology Data Exchange (ETDEWEB)

    Sosa, M. [Departamento de Ingeniería Física, Campus León, Universidad de Guanajuato, 37150 León, Guanajuato (Mexico); Universidad de Sevilla, Departamento de Física Aplicada II, E.T.S. Arquitectura, Av. Reina Mercedes, 2, 41012 Sevilla (Spain); Manjón, G., E-mail: manjon@us.es [Universidad de Sevilla, Departamento de Física Aplicada II, E.T.S. Arquitectura, Av. Reina Mercedes, 2, 41012 Sevilla (Spain); Mantero, J.; García-Tenorio, R. [Universidad de Sevilla, Departamento de Física Aplicada II, E.T.S. Arquitectura, Av. Reina Mercedes, 2, 41012 Sevilla (Spain)

    2014-05-01

    The objective of this work is to propose an exponential fit for the low alpha-counting efficiency as a function of a sample quenching parameter using a Quantulus liquid scintillation counter. The sample quenching parameter in a Quantulus is the Spectral Quench Parameter of the External Standard (SQP(E)), which is defined as the number of channel under which lies the 99% of Compton spectrum generated by a gamma emitter ({sup 152}Eu). Although in the literature one usually finds a polynomial fitting of the alpha counting efficiency, it is shown here that an exponential function is a better description. - Highlights: • We have studied the quenching in alpha measurement by liquid scintillation counting. • We have reviewed typical fitting of alpha counting efficiency versus quenching parameter. • Exponential fitting of data is proposed as better fitting. • We consider exponential fitting has a physical basis.

  19. Modal Logics with Counting

    Science.gov (United States)

    Areces, Carlos; Hoffmann, Guillaume; Denis, Alexandre

    We present a modal language that includes explicit operators to count the number of elements that a model might include in the extension of a formula, and we discuss how this logic has been previously investigated under different guises. We show that the language is related to graded modalities and to hybrid logics. We illustrate a possible application of the language to the treatment of plural objects and queries in natural language. We investigate the expressive power of this logic via bisimulations, discuss the complexity of its satisfiability problem, define a new reasoning task that retrieves the cardinality bound of the extension of a given input formula, and provide an algorithm to solve it.

  20. Digital coincidence counting

    International Nuclear Information System (INIS)

    Buckman, S.M.; Ius, D.

    1996-01-01

    This paper reports on the development of a digital coincidence-counting system which comprises a custom-built data acquisition card and associated PC software. The system has been designed to digitise the pulse-trains from two radiation detectors at a rate of 20 MSamples/s with 12-bit resolution. Through hardware compression of the data, the system can continuously record both individual pulse-shapes and the time intervals between pulses. Software-based circuits are used to process the stored pulse trains. These circuits are constructed simply by linking together icons representing various components such as coincidence mixers, time delays, single-channel analysers, deadtimes and scalers. This system enables a pair of pulse trains to be processed repeatedly using any number of different methods. Some preliminary results are presented in order to demonstrate the versatility and efficiency of this new method. (orig.)

  1. Digital coincidence counting

    Science.gov (United States)

    Buckman, S. M.; Ius, D.

    1996-02-01

    This paper reports on the development of a digital coincidence-counting system which comprises a custom-built data acquisition card and associated PC software. The system has been designed to digitise the pulse-trains from two radiation detectors at a rate of 20 MSamples/s with 12-bit resolution. Through hardware compression of the data, the system can continuously record both individual pulse-shapes and the time intervals between pulses. Software-based circuits are used to process the stored pulse trains. These circuits are constructed simply by linking together icons representing various components such as coincidence mixers, time delays, single-channel analysers, deadtimes and scalers. This system enables a pair of pulse trains to be processed repeatedly using any number of different methods. Some preliminary results are presented in order to demonstrate the versatility and efficiency of this new method.

  2. High efficiency and stable white OLED using a single emitter

    Energy Technology Data Exchange (ETDEWEB)

    Li, Jian [Arizona State Univ., Tempe, AZ (United States). School of Mechanical, Aerospace, Chemical and Materials Engineering

    2016-01-18

    The ultimate objective of this project was to demonstrate an efficient and stable white OLED using a single emitter on a planar glass substrate. The focus of the project is on the development of efficient and stable square planar phosphorescent emitters and evaluation of such class of materials in the device settings. Key challenges included improving the emission efficiency of molecular dopants and excimers, controlling emission color of emitters and their excimers, and improving optical and electrical stability of emissive dopants. At the end of this research program, the PI has made enough progress to demonstrate the potential of excimer-based white OLED as a cost-effective solution for WOLED panel in the solid state lighting applications.

  3. A polarization-insensitive plasmonic photoconductive terahertz emitter

    KAUST Repository

    Li, Xurong

    2017-11-16

    We present a polarization-insensitive plasmonic photoconductive terahertz emitter that uses a two-dimensional array of nanoscale cross-shaped apertures as the plasmonic contact electrodes. The geometry of the cross-shaped apertures is set to maximize optical pump absorption in close proximity to the contact electrodes. The two-dimensional symmetry of the cross-shaped apertures offers a polarization-insensitive interaction between the plasmonic contact electrodes and optical pump beam. We experimentally demonstrate a polarization-insensitive terahertz radiation from the presented emitter in response to a femtosecond optical pump beam and similar terahertz radiation powers compared to previously demonstrated polarization-sensitive photoconductive emitters with plasmonic contact electrode gratings at the optimum optical pump polarization.

  4. Control and Data Analysis for Emittance Measuring Devices

    CERN Document Server

    Hoffmann, T

    2001-01-01

    Due to the wide range of heavy ion beam intensities and energies in the GSI linac and the associated transfer channel to the synchrotron, several different types of emittance measurement systems have been established. Many common devices such as slit/grid or dipole-sweep systems are integrated into the GSI control system. Other systems like the single shot pepper pot method using CCD-cameras or stand-alone slit/grid set-ups are connected to personal computers. An overview is given about the various systems and their software integration. Main interest is directed on the software development for emittance front-end control and data analysis such as evaluation algorithms or graphical presentation of the results. In addition, special features for improved usability of the software such as data export, project databases and automatic report generation will be presented. An outlook on a unified evaluation procedure for all different types of emittance measurement is given.

  5. Emittance growth in the DARHT Axis-II Downstream Transport

    Energy Technology Data Exchange (ETDEWEB)

    Ekdahl, Jr., Carl August [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Schulze, Martin E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-04-14

    Using a particle-in-cell (PIC) code, we investigated the possibilities for emittance growth through the quadrupole magnets of the system used to transport the high-current electron beam from an induction accelerator to the bremsstrahlung converter target used for flash radiography. We found that even highly mismatched beams exhibited little emittance growth (< 6%), which we attribute to softening of their initial hard edge current distributions. We also used this PIC code to evaluate the accuracy of emittance measurements using a solenoid focal scan following the quadrupole magnets. If the beam is round after the solenoids, the simulations indicate that the measurement is highly accurate, but it is substantially inaccurate for elliptical beams

  6. Low Emittance Tuning Studies for SuperB

    Energy Technology Data Exchange (ETDEWEB)

    Liuzzo, Simone; /INFN, Pisa; Biagini, Maria; /INFN, Rome; Raimondi, Pantaleo; /INFN, Rome; Donald, Martin; /SLAC

    2012-07-06

    SuperB[1] is an international project for an asymmetric 2 rings collider at the B mesons cm energy to be built in the Rome area in Italy. The two rings will have very small beam sizes at the Interaction Point and very small emittances, similar to the Linear Collider Damping Rings ones. In particular, the ultra low vertical emittances, 7 pm in the LER and 4 pm in the HER, need a careful study of the misalignment errors effects on the machine performances. Studies on the closed orbit, vertical dispersion and coupling corrections have been carried out in order to specify the maximum allowed errors and to provide a procedure for emittance tuning. A new tool which combines MADX and Matlab routines has been developed, allowing for both corrections and tuning. Results of these studies are presented.

  7. Ion concentration in micro and nanoscale electrospray emitters.

    Science.gov (United States)

    Yuill, Elizabeth M; Baker, Lane A

    2018-06-01

    Solution-phase ion transport during electrospray has been characterized for nanopipettes, or glass capillaries pulled to nanoscale tip dimensions, and micron-sized electrospray ionization emitters. Direct visualization of charged fluorophores during the electrospray process is used to evaluate impacts of emitter size, ionic strength, analyte size, and pressure-driven flow on heterogeneous ion transport during electrospray. Mass spectrometric measurements of positively- and negatively-charged proteins were taken for micron-sized and nanopipette emitters under low ionic strength conditions to further illustrate a discrepancy in solution-driven transport of charged analytes. A fundamental understanding of analyte electromigration during electrospray, which is not always considered, is expected to provide control over selective analyte depletion and enrichment, and can be harnessed for sample cleanup. Graphical abstract Fluorescence micrographs of ion migration in nanoscale pipettes while solution is electrosprayed.

  8. Emittance measurement for high-brightness electron guns

    International Nuclear Information System (INIS)

    Kobayashi, H.; Kurihara, T.; Sato, I.; Asami, A.; Yamazaki, Y.; Otani, S.; Ishizawa, Y.

    1992-01-01

    An emittance measurement system based on a high-precision pepper-pot technique has been developed for electron guns with low emittance of around πmm-mrad. Electron guns with a 1 mmφ cathode, the material of which is impregnated tungsten or single-crystal lanthanum hexaboride (La 1-x Ce x )B 6 , have been developed. The performance has been evaluated by putting stress on cathode roughness, which gives rise to an angular divergence, according to the precise emittance measurement system. A new type of cathode holder, which is a modified version of the so called Vogel type, was developed and the beam uniformity has been improved. (Author) 5 figs., tab., 9 refs

  9. Transverse and longitudinal emittance measurements in the ELSA linac

    International Nuclear Information System (INIS)

    Loulergue, A.; Dowell, D.H.; Joly, S.; De Brion, J.P.; Haouat, G.; Schumann, F.

    1997-01-01

    The ELSA RF linac photoinjector has been designed to deliver high-brightness electron beams. The present paper deals with the transverse and longitudinal emittance measurements, at different locations along the ELSA beam line, and the analysis of their variations as a function of the photoinjector parameters : magnetic field generated by the anode focusing lens, bunch charge and pulse duration. While transverse emittance has been already studied in other similar installations, there has been little study of the electron beam longitudinal dynamics. Experimental results are presented and compared to simulation-code expectations. For 2.0 nC, 85 A electron bunches, a normalized rms emittance of 2 π mm mrad and a brightness of 4.5 x 10 13 A/(π m rad) 2 at the linac exit have been measured as well as less than 10 keV rms energy spread (or less than 0.1% at 16.5 MeV). (orig.)

  10. RF emittance in a low energy electron linear accelerator

    Science.gov (United States)

    Sanaye Hajari, Sh.; Haghtalab, S.; Shaker, H.; Kelisani, M. Dayyani

    2018-04-01

    Transverse beam dynamics of an 8 MeV low current (10 mA) S-band traveling wave electron linear accelerator has been studied and optimized. The main issue is to limit the beam emittance, mainly induced by the transverse RF forces. The linac is being constructed at Institute for Research in Fundamental Science (IPM), Tehran Iran Labeled as Iran's First Linac, nearly all components of this accelerator are designed and constructed within the country. This paper discusses the RF coupler induced field asymmetry and the corresponding emittance at different focusing levels, introduces a detailed beam dynamics design of a solenoid focusing channel aiming to reduce the emittance growth and studies the solenoid misalignment tolerances. In addition it has been demonstrated that a prebuncher cavity with appropriate parameters can help improving the beam quality in the transverse plane.

  11. DC-SC Photoinjector with Low Emittance at Peking University

    CERN Document Server

    Xiang Rong; Hao, J; Huang, Senlin; Lu Xiang Yang; Quan, Shengwen; Zhang, Baocheng; Zhao, Kui

    2005-01-01

    High average power Free Electron Lasers require the high quality electron beams with the low emittance and the sub-picosecond bunches. The design of DC-SC photoinjector, directly combining a DC photoinjector with an SRF cavity, can produce high average current beam with moderate bunch charge and high duty factor. Because of the DC gun, the emittance increases quickly at the beginning, so a carefully design is needed to control that. In this paper, the simulation of an upgraded design has been done to lower the normalized emittance below 1.5mm·mrad. The photoinjector consists of a DC gap and a 2+1/2-cell SRF cavity, and it is designed to produce 4.2 MeV electron beams at 100pC bunch charge and 81.25MHz repetition rate (8 mA average current).

  12. Laser Process for Selective Emitter Silicon Solar Cells

    Directory of Open Access Journals (Sweden)

    G. Poulain

    2012-01-01

    Full Text Available Selective emitter solar cells can provide a significant increase in conversion efficiency. However current approaches need many technological steps and alignment procedures. This paper reports on a preliminary attempt to reduce the number of processing steps and therefore the cost of selective emitter cells. In the developed procedure, a phosphorous glass covered with silicon nitride acts as the doping source. A laser is used to open locally the antireflection coating and at the same time achieve local phosphorus diffusion. In this process the standard chemical etching of the phosphorous glass is avoided. Sheet resistance variation from 100 Ω/sq to 40 Ω/sq is demonstrated with a nanosecond UV laser. Numerical simulation of the laser-matter interaction is discussed to understand the dopant diffusion efficiency. Preliminary solar cells results show a 0.5% improvement compared with a homogeneous emitter structure.

  13. Radiation doses and risks from internal emitters

    International Nuclear Information System (INIS)

    Harrison, John; Day, Philip

    2008-01-01

    This review updates material prepared for the UK Government Committee Examining Radiation Risks from Internal Emitters (CERRIE) and also refers to the new recommendations of the International Commission on Radiological Protection (ICRP) and other recent developments. Two conclusions from CERRIE were that ICRP should clarify and elaborate its advice on the use of its dose quantities, equivalent and effective dose, and that more attention should be paid to uncertainties in dose and risk estimates and their implications. The new ICRP recommendations provide explanations of the calculation and intended purpose of the protection quantities, but further advice on their use would be helpful. The new recommendations refer to the importance of understanding uncertainties in estimates of dose and risk, although methods for doing this are not suggested. Dose coefficients (Sv per Bq intake) for the inhalation or ingestion of radionuclides are published as reference values without uncertainty. The primary purpose of equivalent and effective dose is to enable the summation of doses from different radionuclides and from external sources for comparison with dose limits, constraints and reference levels that relate to stochastic risks of whole-body radiation exposure. Doses are calculated using defined biokinetic and dosimetric models, including reference anatomical data for the organs and tissues of the human body. Radiation weighting factors are used to adjust for the different effectiveness of different radiation types, per unit absorbed dose (Gy), in causing stochastic effects at low doses and dose rates. Tissue weighting factors are used to take account of the contribution of individual organs and tissues to overall detriment from cancer and hereditary effects, providing a simple set of rounded values chosen on the basis of age- and sex-averaged values of relative detriment. While the definition of absorbed dose has the scientific rigour required of a basic physical quantity

  14. Cerenkov counting and Cerenkov-scintillation counting with high refractive index organic liquids using a liquid scintillation counter

    Energy Technology Data Exchange (ETDEWEB)

    Wiebe, L I; Helus, F; Maier-Borst, W [Deutsches Krebsforschungszentrum, Heidelberg (Germany, F.R.). Inst. fuer Nuklearmedizin

    1978-06-01

    /sup 18/F and /sup 14/C radioactivity was measured in methyl salicylate (MS), a high refractive index hybrid Cherenkov-scintillation generating medium, using a liquid scintillation counter. At concentrations of up to 21.4%, in MS, dimethyl sulfoxide (DMSO) quenched /sup 14/C fluorescence, and with a 10-fold excess of DMSO over MS, /sup 18/F count rates were reduced below that for DMSO alone, probably as a result of concentration-independent self-quenching due to 'dark-complex' formation. DMSO in lower concentrations did not reduce the counting efficiency of /sup 18/F in MS. Nitrobenzene was a concentration-dependent quencher for both /sup 14/C and /sup 18/F in MS. Chlorobenzene (CB) and DMSO were both found to be weak Cherenkov generators with /sup 18/F. Counting efficiencies for /sup 18/F in MS, CB, and DMSO were 50.3, 7.8 and 4.3% respectively in the coincidence counting mode, and 58.1, 13.0 and 6.8% in the singles mode. /sup 14/C efficiencies were 14.4 and 22.3% for coincidence and singles respectively, and 15.3 and 42.0% using a modern counter designed for coincidence and single photon counting. The high /sup 14/C and /sup 18/F counting efficiency in MS are discussed with respect to excitation mechanism, on the basis of quench and channels ratios changes observed. It is proposed that MS functions as an efficient Cherenkov-scintillation generator for high-energy beta emitters such as /sup 18/F, and as a low-efficiency scintillator for weak beta emitting radionuclides such as /sup 14/C.

  15. Cerenkov counting and Cerenkov-scintillation counting with high refractive index organic liquids using a liquid scintillation counter

    International Nuclear Information System (INIS)

    Wiebe, L.I.; Helus, F.; Maier-Borst, W.

    1978-01-01

    18 F and 14 C radioactivity was measured in methyl salicylate (MS), a high refractive index hybrid Cherenkov-scintillation generating medium, using a liquid scintillation counter. At concentrations of up to 21.4%, in MS, dimethyl sulfoxide (DMSO) quenched 14 C fluorescence, and with a 10-fold excess of DMSO over MS, 18 F count rates were reduced below that for DMSO alone, probably as a result of concentration-independent self-quenching due to 'dark-complex' formation. DMSO in lower concentrations did not reduce the counting efficiency of 18 F in MS. Nitrobenzene was a concentration-dependent quencher for both 14 C and 18 F in MS. Chlorobenzene (CB) and DMSO were both found to be weak Cherenkov generators with 18 F. Counting efficiencies for 18 F in MS, CB, and DMSO were 50.3, 7.8 and 4.3% respectively in the coincidence counting mode, and 58.1, 13.0 and 6.8% in the singles mode. 14 C efficiencies were 14.4 and 22.3% for coincidence and singles respectively, and 15.3 and 42.0% using a modern counter designed for coincidence and single photon counting. The high 14 C and 18 F counting efficiency in MS are discussed with respect to excitation mechanism, on the basis of quench and channels ratios changes observed. It is proposed that MS functions as an efficient Cherenkov-scintillation generator for high-energy beta emitters such as 18 F, and as a low-efficiency scintillator for weak beta emitting radionuclides such as 14 C. (author)

  16. Counting statistics in low level radioactivity measurements fluctuating counting efficiency

    International Nuclear Information System (INIS)

    Pazdur, M.F.

    1976-01-01

    A divergence between the probability distribution of the number of nuclear disintegrations and the number of observed counts, caused by counting efficiency fluctuation, is discussed. The negative binominal distribution is proposed to describe the probability distribution of the number of counts, instead of Poisson distribution, which is assumed to hold for the number of nuclear disintegrations only. From actual measurements the r.m.s. amplitude of counting efficiency fluctuation is estimated. Some consequences of counting efficiency fluctuation are investigated and the corresponding formulae are derived: (1) for detection limit as a function of the number of partial measurements and the relative amplitude of counting efficiency fluctuation, and (2) for optimum allocation of the number of partial measurements between sample and background. (author)

  17. Optical characterization of OLED emitter properties by radiation pattern analyses

    Energy Technology Data Exchange (ETDEWEB)

    Flaemmich, Michael

    2011-09-08

    Researches in both, academia and industry are investigating optical loss channels in OLED layered systems by means of optical simulation tools in order to derive promising concepts for a further enhancement of the overall device performance. Besides other factors, the prospects of success of such optimization strategies rely severely on the credibility of the optical input data. The present thesis provides a guideline to measure the active optical properties of OLED emitter materials in situ by radiation pattern analyses. Reliable and widely applicable methods are introduced to determine the internal electroluminescence spectrum, the profile of the emission zone, the dipole emitter orientation, and the internal luminescence quantum efficiency of emissive materials from the optical far field emission of OLEDs in electrical operation. The proposed characterization procedures are applied to sets of OLEDs containing both, fluorescent polymeric materials as well as phosphorescent small-molecular emitters, respectively. On the one hand, quite expected results are obtained. On the other hand, several novel and truly surprising results are found. Most importantly, this thesis contains the first report of a non-isotropic, mainly parallel emitter orientation in a phosphorescent small-molecular guest-host system (Ir(MDQ)2(acac) in a-NPD). Due to the latter result, emitter orientation based optimization of phosphorescent OLEDs seems to be within reach. Since parallel dipoles emit preferably into air, the utilization of smart emissive materials with advantageous molecular orientation is capable to boost the efficiency of phosphorescent OLEDs by 50%. Materials design, the influence of the matrix material and the substrate, as well as film deposition conditions are just a few parameters that need to be studied further in order to exploit the huge potential of the dipole emitter orientation in phosphorescent OLEDs.

  18. Calculating emittance for Gaussian and Non-Gaussian distributions by the method of correlations for slits

    International Nuclear Information System (INIS)

    Tan, Cheng-Yang; Fermilab

    2006-01-01

    One common way for measuring the emittance of an electron beam is with the slits method. The usual approach for analyzing the data is to calculate an emittance that is a subset of the parent emittance. This paper shows an alternative way by using the method of correlations which ties the parameters derived from the beamlets to the actual parameters of the parent emittance. For parent distributions that are Gaussian, this method yields exact results. For non-Gaussian beam distributions, this method yields an effective emittance that can serve as a yardstick for emittance comparisons

  19. CILogon-HA. Higher Assurance Federated Identities for DOE Science

    Energy Technology Data Exchange (ETDEWEB)

    Basney, James [Univ. of Illinois, Urbana-Champaign, IL (United States)

    2015-08-01

    The CILogon-HA project extended the existing open source CILogon service (initially developed with funding from the National Science Foundation) to provide credentials at multiple levels of assurance to users of DOE facilities for collaborative science. CILogon translates mechanism and policy across higher education and grid trust federations, bridging from the InCommon identity federation (which federates university and DOE lab identities) to the Interoperable Global Trust Federation (which defines standards across the Worldwide LHC Computing Grid, the Open Science Grid, and other cyberinfrastructure). The CILogon-HA project expanded the CILogon service to support over 160 identity providers (including 6 DOE facilities) and 3 internationally accredited certification authorities. To provide continuity of operations upon the end of the CILogon-HA project period, project staff transitioned the CILogon service to operation by XSEDE.

  20. Prospects of HA-Based Universal Influenza Vaccine

    Directory of Open Access Journals (Sweden)

    Anwar M. Hashem

    2015-01-01

    Full Text Available Current influenza vaccines afford substantial protection in humans by inducing strain-specific neutralizing antibodies (Abs. Most of these Abs target highly variable immunodominant epitopes in the globular domain of the viral hemagglutinin (HA. Therefore, current vaccines may not be able to induce heterosubtypic immunity against the divergent influenza subtypes. The identification of broadly neutralizing Abs (BnAbs against influenza HA using recent technological advancements in antibody libraries, hybridoma, and isolation of single Ab-secreting plasma cells has increased the interest in developing a universal influenza vaccine as it could provide life-long protection. While these BnAbs can serve as a source for passive immunotherapy, their identification represents an important step towards the design of such a universal vaccine. This review describes the recent advances and approaches used in the development of universal influenza vaccine based on highly conserved HA regions identified by BnAbs.

  1. Polarization measurements made on LFRA and OASIS emitter arrays

    Science.gov (United States)

    Geske, Jon; Sparkman, Kevin; Oleson, Jim; Laveigne, Joe; Sieglinger, Breck; Marlow, Steve; Lowry, Heard; Burns, James

    2008-04-01

    Polarization is increasingly being considered as a method of discrimination in passive sensing applications. In this paper the degree of polarization of the thermal emission from the emitter arrays of two new Santa Barbara Infrared (SBIR) micro-bolometer resistor array scene projectors was characterized at ambient temperature and at 77 K. The emitter arrays characterized were from the Large Format Resistive Array (LFRA) and the Optimized Arrays for Space-Background Infrared Simulation (OASIS) scene projectors. This paper reports the results of this testing.

  2. Beam emittance reduction during operation of Indus-2

    Energy Technology Data Exchange (ETDEWEB)

    Fakhri, Ali Akbar, E-mail: fakhri@rrcat.gov.in; Kant, Pradeep; Ghodke, A. D.; Singh, Gurnam [Raja Ramanna Centre for Advanced Technology, Indore 452 013 (India)

    2015-11-15

    Indus-2 storage ring is a 2.5 GeV third generation synchrotron radiation source. This source was commissioned using a moderate optics. Beam injection was accomplished using an off momentum electron beam to avoid difficulties faced in storage of beam at 550 MeV. The injection procedure and relevant beam dynamical studies are discussed. The switch over from the moderate optics to low emittance optics is done at 2.5 GeV after storing the electron beam. The procedure evolved to reduce the beam emittance and its implementation during the operation is discussed.

  3. Nanodiamonds with photostable, sub-gigahertz linewidth quantum emitters

    Directory of Open Access Journals (Sweden)

    Toan Trong Tran

    2017-11-01

    Full Text Available Single-photon emitters with narrow linewidths are highly sought after for applications in quantum information processing and quantum communications. In this letter, we report on a bright, highly polarized near infrared single photon emitter embedded in diamond nanocrystals with a narrow, sub-GHz optical linewidth at 10 K. The observed zero-phonon line at ∼780 nm is optically stable under low power excitation and blue shifts as the excitation power increases. Our results highlight the prospect for using new near infrared color centers in nanodiamonds for quantum applications.

  4. Nanodiamonds with photostable, sub-gigahertz linewidth quantum emitters

    Science.gov (United States)

    Tran, Toan Trong; Kianinia, Mehran; Bray, Kerem; Kim, Sejeong; Xu, Zai-Quan; Gentle, Angus; Sontheimer, Bernd; Bradac, Carlo; Aharonovich, Igor

    2017-11-01

    Single-photon emitters with narrow linewidths are highly sought after for applications in quantum information processing and quantum communications. In this letter, we report on a bright, highly polarized near infrared single photon emitter embedded in diamond nanocrystals with a narrow, sub-GHz optical linewidth at 10 K. The observed zero-phonon line at ˜780 nm is optically stable under low power excitation and blue shifts as the excitation power increases. Our results highlight the prospect for using new near infrared color centers in nanodiamonds for quantum applications.

  5. Epitaxial Growth of Germanium on Silicon for Light Emitters

    Directory of Open Access Journals (Sweden)

    Chengzhao Chen

    2012-01-01

    Full Text Available This paper describes the role of Ge as an enabler for light emitters on a Si platform. In spite of the large lattice mismatch of ~4.2% between Ge and Si, high-quality Ge layers can be epitaxially grown on Si by ultrahigh-vacuum chemical vapor deposition. Applications of the Ge layers to near-infrared light emitters with various structures are reviewed, including the tensile-strained Ge epilayer, the Ge epilayer with a delta-doping SiGe layer, and the Ge/SiGe multiple quantum wells on Si. The fundamentals of photoluminescence physics in the different Ge structures are discussed briefly.

  6. Modulation characteristics of graphene-based thermal emitters

    Science.gov (United States)

    Mahlmeister, Nathan Howard; Lawton, Lorreta Maria; Luxmoore, Isaac John; Nash, Geoffrey Richard

    2016-01-01

    We have investigated the modulation characteristics of the emission from a graphene-based thermal emitter both experimentally and through simulations using finite element method modelling. Measurements were performed on devices containing square multilayer graphene emitting areas, with the devices driven by a pulsed DC drive current over a range of frequencies. Simulations show that the dominant heat path is from the emitter to the underlying substrate, and that the thermal resistance between the graphene and the substrate determines the modulation characteristics. This is confirmed by measurements made on devices in which the emitting area is encapsulated by hexagonal boron nitride.

  7. Spectrum of classes of point emitters of electromagnetic wave fields.

    Science.gov (United States)

    Castañeda, Román

    2016-09-01

    The spectrum of classes of point emitters has been introduced as a numerical tool suitable for the design, analysis, and synthesis of non-paraxial optical fields in arbitrary states of spatial coherence. In this paper, the polarization state of planar electromagnetic wave fields is included in the spectrum of classes, thus increasing its modeling capabilities. In this context, optical processing is realized as a filtering on the spectrum of classes of point emitters, performed by the complex degree of spatial coherence and the two-point correlation of polarization, which could be implemented dynamically by using programmable optical devices.

  8. Emittances Studies at the Fermilab/NICADD Photoinjector Laboratory

    CERN Document Server

    Tikhoplav, Rodion; Melissinos, A C; Regis-Guy Piot, Philippe

    2005-01-01

    The Fermilab/NICADD photoinjector incorporates an L-band rf-gun capable of generating 1-10 nC bunches. The bunches are then accelerated to 16 MeV with a TESLA superconducting cavity. In the present paper we present parametric studies of transverse emittances and energy spread for a various operating points of the electron source (RF-gun E-field, laser length and spot size, and solenoid settings). We especially study the impact, on transverse emittance, of Gaussian and Plateau temporal distribution of the photocathode drive-laser.

  9. Mirrorless lasing from light emitters in percolating clusters

    Science.gov (United States)

    Burlak, Gennadiy; Rubo, Y. G.

    2015-07-01

    We describe the lasing effect in the three-dimensional percolation system, where the percolating cluster is filled by active media composed by light emitters excited noncoherently. We show that, due to the presence of a topologically nontrivial photonic structure, the stimulated emission is modified with respect to both conventional and random lasers. The time dynamics and spectra of the lasing output are studied numerically with finite-difference time-domain approach. The Fermat principle and Monte Carlo approach are applied to characterize the optimal optical path and interconnection between the radiating emitters. The spatial structure of the laser mode is found by a long-time FDTD simulation.

  10. Model of emittance growth in a self-pinched beam

    International Nuclear Information System (INIS)

    Lee, E.P.; Yu, S.S.

    1979-01-01

    A semi-phenomenological formula is proposed for the change of emittance of a self-pinched beam which is not matched to its equilibrium radius. Near equilibrium this formula, coupled with an envelope equation, yields the damped sausage oscillations observed in simulation and experiments. For a beam which is injected cold (no transverse velocity spread), the formula coincides with the analytically calculated initial growth of emittance. The basic theory is developed here and used to compute the linear damping rate for several current profiles. The resultant non-linear increase in equilibrium quantities is also calculated in lowest order of the degree of mismatch

  11. Active packaged lamb with oxygen scavenger/carbon dioxide emitter sachet: physical-chemical and microbiological stability during refrigerated storage

    Directory of Open Access Journals (Sweden)

    Marco Antonio Trindade

    2013-09-01

    Full Text Available Lamb meat has been commercialized in Brazil almost exclusively as a frozen product due to the longer shelf life provided by freezing when compared to refrigeration. However, as a result of the current trend of increased demand for convenience products, a need has emerged for further studies to facilitate the marketing of refrigerated lamb cuts. The aim of the present study was to evaluate the contribution of active packaging technology in extending the shelf life of lamb loins (Longissimus lumborum stored under refrigeration (1±1 ° C when compared to the traditional vacuum packaging. For this purpose, two kinds of sachets were employed: oxygen scavenger sachet and oxygen scavenger/carbon dioxide emitter sachet. Experiments were conducted in three treatments: 1 Vacuum (Control, 2 Vacuum + oxygen scavenger sachet and 3 Vacuum + oxygen scavenger/carbon dioxide emitter sachet. Microbiological (counts of anaerobic psychrotrophs, coliform at 45 ° C, coagulase-positive staphylococci, Salmonella and lactic acid bacteria and physical-chemical (thiobarbituric acid reactive substances, objective color, pH value, water loss from cooking and shear force analyses were carried out weekly for a total storage period of 28 days. The experiment was performed three times for all treatments. Results showed that the lamb meat remained stable with respect to the majority of the evaluated physical and chemical indexes and remained within the standards established by Brazilian legislation for pathogenic microorganisms throughout the storage period in all three packaging systems. However, all treatments presented elevated counts of anaerobic psychrotrophic microorganisms and lactic acid bacteria, reaching values above 10(7 CFU/g at 28 days of storage. Thus, under the conditions tested, neither the oxygen scavenger sachet nor the dual function sachet (oxygen scavenger/carbon dioxide emitter were able to extend the shelf life of refrigerated lamb loin when added to this

  12. Effect of Water-Glass Coating on HA and HA-TCP Samples for MSCs Adhesion, Proliferation, and Differentiation

    Directory of Open Access Journals (Sweden)

    Indu Bajpai

    2016-01-01

    Full Text Available Ca-P and silicon based materials have become very popular as bone tissue engineering materials. In this study, water-glass (also known as sodium silicate glass was coated on sintered hydroxyapatite (HA and HA-TCP (TCP stands for tricalcium phosphate samples and subsequently heat-treated at 600°C for 2 hrs. X-rays diffraction showed the presence of β- and α-TCP phases along with HA in the HA-TCP samples. Samples without coating, with water-glass coating, and heat-treated after water-glass coating were used to observe the adhesion and proliferation response of bone marrow derived-mesenchymal stem cells (MSCs. Cell culture was carried out for 4 hrs, 1 day, and 7 days. Interestingly, all samples showed similar response for cell adhesion and proliferation up to 7-day culture but fibronectin, E-cadherin, and osteogenic differentiation related genes (osteocalcin and osteopontin were significantly induced in heat-treated water-glass coated HA-TCP samples. A water-glass coating on Ca-P samples was not found to influence the cell proliferation response significantly but activated some extracellular matrix genes and induced osteogenic differentiation in the MSCs.

  13. Boundary conditions on the plasma emitter surface in the presence of a particle counter flow: I. Ion emitter

    Energy Technology Data Exchange (ETDEWEB)

    Astrelin, V. T., E-mail: V.T.Astrelin@inp.nsk.su; Kotelnikov, I. A. [Russian Academy of Sciences, Budker Institute of Nuclear Physics, Siberian Branch (Russian Federation)

    2017-02-15

    Emission of positively charged ions from a plasma emitter irradiated by a counterpropagating electron beam is studied theoretically. A bipolar diode with a plasma emitter in which the ion temperature is lower than the electron temperature and the counter electron flow is extracted from the ion collector is calculated in the one-dimensional model. An analog of Bohm’s criterion for ion emission in the presence of a counterpropagating electron beam is derived. The limiting density of the counterpropagating beam in a bipolar diode operating in the space-charge-limited-emission regime is calculated. The full set of boundary conditions on the plasma emitter surface that are required for operation of the high-current optics module in numerical codes used to simulate charged particle sources is formulated.

  14. In vivo detection, localization and measurement of radionuclides in man: a detection system for the localization and measurement of small amounts of photon emitters. Progress report, March 1, 1982-June 30, 1983

    International Nuclear Information System (INIS)

    Laurer, G.R.

    1983-01-01

    The objective was the design, construction and testing of a photon detection system which will yield, simultaneously, information proportional to both the magnitude and the site(s) of deposition of radioactivity accidentally inhaled or ingested or otherwise deposited in the body. The operating principle of the detector system, active collimation, allows the resolution of the position and outline, in space, of the radioactive deposit, i.e., the image of the emitter(s), without the use of separate, external collimating devices. The result of this is an imaging detection system with a much higher counting efficiency than other currently available systems. 20 references, 29 figures

  15. Let's Make Data Count

    Science.gov (United States)

    Budden, A. E.; Abrams, S.; Chodacki, J.; Cruse, P.; Fenner, M.; Jones, M. B.; Lowenberg, D.; Rueda, L.; Vieglais, D.

    2017-12-01

    The impact of research has traditionally been measured by citations to journal publications and used extensively for evaluation and assessment in academia, but this process misses the impact and reach of data and software as first-class scientific products. For traditional publications, Article-Level Metrics (ALM) capture the multitude of ways in which research is disseminated and used, such as references and citations within social media and other journal articles. Here we present on the extension of usage and citation metrics collection to include other artifacts of research, namely datasets. The Make Data Count (MDC) project will enable measuring the impact of research data in a manner similar to what is currently done with publications. Data-level metrics (DLM) are a multidimensional suite of indicators measuring the broad reach and use of data as legitimate research outputs. By making data metrics openly available for reuse in a number of different ways, the MDC project represents an important first step on the path towards the full integration of data metrics into the research data management ecosystem. By assuring researchers that their contributions to scholarly progress represented by data corpora are acknowledged, data level metrics provide a foundation for streamlining the advancement of knowledge by actively promoting desirable best practices regarding research data management, publication, and sharing.

  16. LAWRENCE RADIATION LABORATORY COUNTING HANDBOOK

    Energy Technology Data Exchange (ETDEWEB)

    Group, Nuclear Instrumentation

    1966-10-01

    The Counting Handbook is a compilation of operational techniques and performance specifications on counting equipment in use at the Lawrence Radiation Laboratory, Berkeley. Counting notes have been written from the viewpoint of the user rather than that of the designer or maintenance man. The only maintenance instructions that have been included are those that can easily be performed by the experimenter to assure that the equipment is operating properly.

  17. Improving natural resource management in Viet Nam's Hong Ha ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    2011-07-15

    Jul 15, 2011 ... Improving natural resource management in Viet Nam's Hong Ha commune ... In this work, the research team helped local farmers improve their land ... with a home garden economy, limit forest destruction, diversify crop production, ... low female participation rates in decision making; limited education; rapid ...

  18. Mao & Püha Eliisabet / Jüri Kuuskemaa

    Index Scriptorium Estoniae

    Kuuskemaa, Jüri, 1942-

    2000-01-01

    Kadrioru lossis Väliskunstimuuseumi ekspositsioonis olevast antikvaar August Käbi pärandist pärit maalist. Kunstiteadlase Mai Levini arvates võib maali autoriks olla Rooma kunstnik Tommaso Salini, hüüdnimega Mao. Maali süzee: "Püha Eliisabeti kuulutus". 1 ill

  19. Läkaköha - aktuaalne uurimisteema / Marje Oona

    Index Scriptorium Estoniae

    Oona, Marje, 1963-

    2012-01-01

    TÜ peremeditsiini õppetooli töötajate poolt algatatud uurimistööst, mille eesmärgiks on uurida Bordetella spp. infektsioonide epidemioloogiat, molekulaargeneetikat ja kliinilisi eripärasid ning selgitada läkaköha sagedasema diagnsimise põhjusi Eestis

  20. SUMS Counts-Related Projects

    Data.gov (United States)

    Social Security Administration — Staging Instance for all SUMs Counts related projects including: Redeterminations/Limited Issue, Continuing Disability Resolution, CDR Performance Measures, Initial...

  1. Compton suppression gamma-counting: The effect of count rate

    Science.gov (United States)

    Millard, H.T.

    1984-01-01

    Past research has shown that anti-coincidence shielded Ge(Li) spectrometers enhanced the signal-to-background ratios for gamma-photopeaks, which are situated on high Compton backgrounds. Ordinarily, an anti- or non-coincidence spectrum (A) and a coincidence spectrum (C) are collected simultaneously with these systems. To be useful in neutron activation analysis (NAA), the fractions of the photopeak counts routed to the two spectra must be constant from sample to sample to variations must be corrected quantitatively. Most Compton suppression counting has been done at low count rate, but in NAA applications, count rates may be much higher. To operate over the wider dynamic range, the effect of count rate on the ratio of the photopeak counts in the two spectra (A/C) was studied. It was found that as the count rate increases, A/C decreases for gammas not coincident with other gammas from the same decay. For gammas coincident with other gammas, A/C increases to a maximum and then decreases. These results suggest that calibration curves are required to correct photopeak areas so quantitative data can be obtained at higher count rates. ?? 1984.

  2. A thermionic energy converter with A molybdenum alumina cermet emitter

    NARCIS (Netherlands)

    Gubbels, G.H.M.; Wolff, L.R.; Metselaar, R.; Yogi Goswami, D.

    1988-01-01

    The I-V characteristics of a thermionic converter equipped with a Mo-1w/o AI203 emitter and a Mo collector were measured. The conditions were varied over a limited range without, as well as with Cs. Work functions of Mo as well as Mo-1w/o AI203 were determined. Measurements were carried out in a

  3. Laser-assisted electron emission from gated field-emitters

    CERN Document Server

    Ishizuka, H; Yokoo, K; Mimura, H; Shimawaki, H; Hosono, A

    2002-01-01

    Enhancement of electron emission by illumination of gated field-emitters was studied using a 100 mW cw YAG laser at a wavelength of 532 nm, intensities up to 10 sup 7 W/m sup 2 and mechanically chopped with a rise time of 4 mu s. When shining an array of 640 silicon emitters, the emission current responded quickly to on-off of the laser. The increase of the emission current was proportional to the basic emission current at low gate voltages, but it was saturated at approx 3 mu A as the basic current approached 100 mu A with the increase of gate voltage. The emission increase was proportional to the square root of laser power at low gate voltages and to the laser power at elevated gate voltages. For 1- and 3-tip silicon emitters, the rise and fall of the current due to on-off of the laser showed a significant time lag. The magnitude of emission increase was independent of the position of laser spot on the emitter base and reached 2 mu A at a basic current of 5 mu A without showing signs of saturation. The mech...

  4. Calculation Of Extraction Optics For Ion System With Plazma Emitter

    CERN Document Server

    Frolov, B A

    2004-01-01

    The 2-D code for simulating of ion optics system of positive ion extraction from a plasma source is described. Example calculation of 100 kV optics for the extraction ion IHEP gun is presented. The trajectories of particles and emittance plots are resulted. The aberrations influ-ence strongly on ion optics for considered geometry.

  5. Short-lived positron emitter labeled radiotracers - present status

    International Nuclear Information System (INIS)

    Fowler, J.S.; Wolf, A.P.

    1982-01-01

    The preparation of labelled compounds is important for the application of positron emission transaxial tomography (PETT) in biomedical sciences. This paper describes problems and progress in the synthesis of short-lived positron emitter ( 11 C, 18 F, 13 N) labelled tracers for PETT. Synthesis of labelled sugars, amino acids, and neurotransmitter receptors (pimozide and spiroperidol tagged with 11 C) is discussed in particular

  6. Scanning Emitter Lifetime Imaging Microscopy for Spontaneous Emission Control

    DEFF Research Database (Denmark)

    Frimmer, Martin; Chen, Yuntian; Koenderink, A. Femius

    2011-01-01

    We report an experimental technique to map and exploit the local density of optical states of arbitrary planar nanophotonic structures. The method relies on positioning a spontaneous emitter attached to a scanning probe deterministically and reversibly with respect to its photonic environment while...

  7. Emittance control and RF bunch compression in the NSRRC photoinjector

    International Nuclear Information System (INIS)

    Lau, W.K.; Hung, S.B.; Lee, A.P.; Chou, C.S.; Huang, N.Y.

    2011-01-01

    The high-brightness photoinjector being constructed at the National Synchrotron Radiation Research Center is for testing new accelerator and light-source concepts. It is the so-called split photoinjector configuration in which a short solenoid magnet is used for emittance compensation. The UV-drive laser pulses are also shaped to produce uniform cylindrical bunches for further reduction of beam emittance. However, limited by the available power from our microwave power system, the nominal accelerating gradient in the S-band booster linac is set at 18 MV/m. A simulation study with PARMELA shows that the linac operating at this gradient fails to freeze the electron beam emittance at low value. A background solenoid magnetic field is applied for beam emittance control in the linac during acceleration. A satisfactory result that meets our preliminary goal has been achieved with the solenoid magnetic field strength at 0.1 T. RF bunch compression as a means to achieve the required beam brightness for high-gain free-electron laser experiments is also examined. The reduction of bunch length to a few hundred femtoseconds can be obtained.

  8. Application of positron emitters to studies on plants

    Energy Technology Data Exchange (ETDEWEB)

    Ishioka, N S; Matsuoka, H [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment; Sekine, T [and others

    1998-10-01

    A newly developed positron emitting tracer imaging system enables us to study dynamically the physiological function of plants, although this system covers, at present, a limited area in a plant. Production of the positron emitters {sup 11}C, {sup 13}N, {sup 18}F and {sup 48}V for this application, using an AVF cyclotron, is described. (author)

  9. Beam emittance of the Stony Brook Tandem-LINAC booster

    International Nuclear Information System (INIS)

    Scholldorf, A.H.

    1984-01-01

    This dissertation is primarily a study of the longitudinal and transverse beam emittance of the Stony Brook Heavy Ion Tandem LINAC Accelerator Facility, with a secondary emphasis on the beam dynamical design of two key elements of the system: a low energy double-drift buncher, and an achromatic double-90 0 LINAC injection system. A transverse emittance measuring system consisting of two translation stages controlled by stepper motors is described. Each stage carried a pair of beam defining slits mounted so that both horizontal and vertical emittances could be measured with only linear motion of the stage assembly. Beam currents were measured directly by a low-noise, high-sensitivity electrometer circuit integrated with the second slit-stage assembly. A mini-computer controlled the motors and acquired and displayed the data. Transverse emittance areas of beams of 12 C, 16 O, 32 S, and 58 Ni were measured at ion source extraction potential, after ion source acceleration, after tandem acceleration, and after LINAC acceleration. The results were analyzed in terms of source sputter-cone geometry, angle straggling in gas and foil strippers, and a variety of other factors

  10. Emittance growth due to beam-gas scattering

    International Nuclear Information System (INIS)

    Raubenheimer, T.O.

    1992-06-01

    The effect of beam-gas scattering on beam emittance is examined by deriving the beam distribution function. The distribution function is found by treating the beam-gas scattering as a filtered Poisson process and calculating the cumulants of the distribution. (author)

  11. Emittance growth in laser-driven RF electron guns

    International Nuclear Information System (INIS)

    Kim, K.J.

    1989-01-01

    A simple analysis for the evolution of the electron-beam phase space distribution in laser-driven rf guns is presented. In particular, formulas are derived for the transverse and longitudinal emittances at the exit of the gun. The results are compared and found to agree well with those from simulation. (Author). 9 refs.; 4 figs

  12. A compact electron gun using field emitter array

    International Nuclear Information System (INIS)

    Asakawa, M.R.; Ikeda, A.; Miyabe, N.; Yamaguchi, S.; Kusaba, M.; Tsunawaki, Y.

    2008-01-01

    A compact electron gun using field emitter array has been developed. With a simple triode configuration consisting of FEA, mid-electrode and anode electrode, the electron gun produces a parallel beam with a diameter of 0.5 mm. This electron gun is applicable for compact radiation sources such as Cherenkov free-electron lasers

  13. Beam aperture and emittance growth in the AGS-Booster

    International Nuclear Information System (INIS)

    Parsa, Z.

    1987-01-01

    The authors have developed analytical tools for calculating the variation of particle action, smear and emittance growth due to nonlinear elements in accelerators (with second order perturbation theory in two dimensions). The authors' results for the AGS-Booster is presented

  14. The emittance of high current heavy ion beams

    International Nuclear Information System (INIS)

    White, N.R.; Devaney, A.S.

    1989-01-01

    Ion implantation is the main application for high current heavy ion beams. Transfer ratio is defined as the ratio of the total ion current leaving the ion source to the current delivered to the endstation. This ratio is monitored and logged and its importance is explained. It is also affected by other factors, such as the isotopic and molecular composition of the total ion beam. The transfer ratio reveals the fraction of ions which are intercepted by parts of the beamline system. The effects of these ions are discussed in two categories: processing purity and reliability. In discussing the emittance of ribbon beams, the two orthogonal planes are usually considered separately. Longitudinal emittance is determined by slot length and by plasma ion temperature. It has already been revealed that the longitudinal divergence of the beams from BF3 is perhaps double that of the beam from arsenic vapour or argon, at the same total perveance from the ion source. This poses the question: why is the ion temperature higher for BF3 than for As or Ar? The transverse emittance is in practical terms dominated by the divergence. It is the most fruitful area for improvement in most real-world systems. There is an intrinsic divergence arising from initial ion energies within the plasma, and there is emittance growth that can occur as a result of aberration in the beam extraction optics. (N.K.)

  15. Porous Emitter Colloid Thruster Performance Characterization Using Optical Techniques

    Science.gov (United States)

    2013-03-01

    that the surface of the cone is equipotential . In order to include this constraint, Laplace’s Equation was used in the axisymmetric case to solve...43 ix Page 3.3 Emitter Surface Imaging...3. Taylor Cone geometry showing the opposing electric and internal surface tension stresses

  16. Selective solar absorber emittance measurement at elevated temperature

    Science.gov (United States)

    Giraud, Philémon; Braillon, Julien; Raccurt, Olivier

    2017-06-01

    Durability of solar components for CSP (Concentrated Solar Power Plant) technologies is a key point to lower cost and ensure their large deployment. These technologies concentrated the solar radiation by means of mirrors on a receiver tube where it is collected as thermal energy. The absorbers are submitted to strong environmental constraints and the degradation of their optical properties (emittance and solar absorbance) have a direct impact on performance. The characterization of a material in such condition is complicated and requires advanced apparatuses, and different measurement methods exist for the determination of the two quantities of relevance regarding an absorber, which are its emittance and its solar absorbance. The objective is to develop new optical equipment for measure the emittance of this solar absorber at elevated temperature. In this paper, we present an optical bench developed for emittance measurement on absorbers is conditions of use. Results will be shown, with a discussion of some factors of influence over this measurement and how to control them.

  17. Auger electron emitters: Insights gained from in vitro experiments

    International Nuclear Information System (INIS)

    Makrigiorgos, G.; Adelstein, S.J.; Kassis, A.I.

    1990-01-01

    This paper outlines the evolution of the current rationale for research into the biological effects of tissue-incorporated Auger electron emitters. The first section is a brief review of the research conducted by several groups in the last fifteen years. The second section describes the in vitro model used in our studies, dosimetric calculations, experimental techniques and recent findings. The third section focuses on the use of Auger electron emitters as in vitro microprobes for the investigation of the radiosensitivity of distinct subcellular components. Examination of the biological effects of the Auger electron emitter 125 I located in different cellular compartments of a single cell line (V 79 hamster lung fibroblast) verifies that DNA is the critical cell structure for radiation damage and that the sensitive sites are of nanometer dimensions. The data from incorporation of several Auger electron emitters at the same location within DNA suggest that there are no saturation effects from the decay of these isotopes (i.e. all the emitted energy is biologically effective) and provide some insight into which of the numerous physical mechanisms accompanying the Auger decay are most important in causing cell damage. Finally the implications of Auger electron emission for radiotherapy and radiation protection in diagnostic nuclear medicine are detailed and further research possibilities are suggested. (orig.)

  18. Accurate measurement of directional emittance of solar energy materials

    NARCIS (Netherlands)

    Nijnatten, van P.A.; Hugo-Le Gof, A.; Granqvist, C.-G.; Lampert, C.M.

    1992-01-01

    Directional emittance plays an important role in the calculation of radiative heat exchange. It partly determines the thermal insulation of single and multiple glazing and the efficiency of solar collectors. An emissiometer has been designed and built, capable for measurements of the directional

  19. Development of new microencapsulated beta emitters for internal radiotherapy

    International Nuclear Information System (INIS)

    Perdrisot, R.; Monteil, J.; Le Jeune, J.J.; Pouliquen, D.; Jallet, P.; Beau, P.; Lepape, A.

    1993-01-01

    We have developed new microencapsulated beta emitter radiotracers which could be used in nuclear medicine for selective internal radiotherapy. Their efficacy was evaluated on B16 melanoma tumor model in mice, using phosphorus 31 spectroscopy. This kind of tracer would allow a precise targetting of beta irradiation

  20. Passive emitter location with Doppler frequency and interferometric measurements

    NARCIS (Netherlands)

    Groot, J.S.; Dam, F.A.M.; Theil, A.

    2008-01-01

    Ground based emitters can be located with a receiver installed on an airborne platform. This paper discusses techniques based on Doppler frequency and differential phase measurements (interferometry). Measurements of the first technique are provided, while we discuss and compare the theoretical

  1. A combined emitter threat assessment method based on ICW-RCM

    Science.gov (United States)

    Zhang, Ying; Wang, Hongwei; Guo, Xiaotao; Wang, Yubing

    2017-08-01

    Considering that the tradition al emitter threat assessment methods are difficult to intuitively reflect the degree of target threaten and the deficiency of real-time and complexity, on the basis of radar chart method(RCM), an algorithm of emitter combined threat assessment based on ICW-RCM (improved combination weighting method, ICW) is proposed. The coarse sorting is integrated with fine sorting in emitter combined threat assessment, sequencing the emitter threat level roughly accordance to radar operation mode, and reducing task priority of the low-threat emitter; On the basis of ICW-RCM, sequencing the same radar operation mode emitter roughly, finally, obtain the results of emitter threat assessment through coarse and fine sorting. Simulation analyses show the correctness and effectiveness of this algorithm. Comparing with classical method of emitter threat assessment based on CW-RCM, the algorithm is visual in image and can work quickly with lower complexity.

  2. The effects of emitter-tied field plates on lateral PNP ionizing radiation response

    International Nuclear Information System (INIS)

    Barnaby, H.J.; Schrimpf, R.D.; Cirba, C.R.; Pease, R.L.; Fleetwood, D.M.; Kosier, S.L.

    1998-03-01

    Radiation response comparisons of lateral PNP bipolar technologies reveal that device hardening may be achieved by extending the emitter contact over the active base. The emitter-tied field plate suppresses recombination of carriers with interface traps

  3. Emitter/absorber interface of CdTe solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Song, Tao, E-mail: tsong241@gmail.com; Sites, James R. [Physics Department, Colorado State University, Fort Collins, Colorado 80523 (United States); Kanevce, Ana [National Renewable Energy Laboratory, Golden, Colorado 80401 (United States)

    2016-06-21

    The performance of CdTe solar cells can be very sensitive to the emitter/absorber interface, especially for high-efficiency cells with high bulk lifetime. Performance losses from acceptor-type interface defects can be significant when interface defect states are located near mid-gap energies. Numerical simulations show that the emitter/absorber band alignment, the emitter doping and thickness, and the defect properties of the interface (i.e., defect density, defect type, and defect energy) can all play significant roles in the interface recombination. In particular, a type I heterojunction with small conduction-band offset (0.1 eV ≤ ΔE{sub C} ≤ 0.3 eV) can help maintain good cell efficiency in spite of high interface defect density, much like with Cu(In,Ga)Se{sub 2} (CIGS) cells. The basic principle is that positive ΔE{sub C}, often referred to as a “spike,” creates an absorber inversion and hence a large hole barrier adjacent to the interface. As a result, the electron-hole recombination is suppressed due to an insufficient hole supply at the interface. A large spike (ΔE{sub C} ≥ 0.4 eV), however, can impede electron transport and lead to a reduction of photocurrent and fill-factor. In contrast to the spike, a “cliff” (ΔE{sub C} < 0 eV) allows high hole concentration in the vicinity of the interface, which will assist interface recombination and result in a reduced open-circuit voltage. Another way to mitigate performance losses due to interface defects is to use a thin and highly doped emitter, which can invert the absorber and form a large hole barrier at the interface. CdS is the most common emitter material used in CdTe solar cells, but the CdS/CdTe interface is in the cliff category and is not favorable from the band-offset perspective. The ΔE{sub C} of other n-type emitter choices, such as (Mg,Zn)O, Cd(S,O), or (Cd,Mg)Te, can be tuned by varying the elemental ratio for an optimal positive value of ΔE{sub C}. These

  4. Low Emittance Guns for the ILC Polarized Electron Beam

    International Nuclear Information System (INIS)

    Clendenin, J. E.; Brachmann, A.; Ioakeimidi, K.; Kirby, R. E.; Maruyama, T.; Miller, R. H.; Wang, J. W.; Zhou, F.

    2007-01-01

    Polarized electron beams generated by DC guns are routinely available at several accelerators including JLAB, Mainz and SLAC. These guns operate with a cathode bias on the order of -100 kV. To minimize space charge effects, relatively long bunches are generated at the gun and then compressed longitudinally external to the gun just before and during initial acceleration. For linear colliders, this compression is accomplished using a combination of rf bunchers. For the basic design of the International Linear Collider (ILC), a 120 kV DC photocathode gun is used to produce a series of nanosecond bunches that are each compressed by two sub-harmonic bunchers (SHBs) followed by an L-band buncher and capture section. The longitudinal bunching process results in a significantly higher emittance than produced by the gun alone. While high-energy experiments using polarized beams are not generally sensitive to the source emittance, there are several benefits to a lower source emittance including a simpler more efficient injector system and a lower radiation load during transport especially at bends as at the damping ring. For the ILC, the SHBs could be eliminated if the voltage of the gun is raised sufficiently. Simulations using the General Particle Tracer (GPT) package indicate that a cathode bias voltage of ≥200 kV should allow both SHBs to be operated at 433 or even 650 MHz, while ≥500 kV would be required to eliminate the SHBs altogether. Simulations can be used to determine the minimum emittance possible if the injector is designed for a given increased voltage. A possible alternative to the DC gun is an rf gun. Emittance compensation, routinely used with rf guns, is discussed for higher-voltage DC guns

  5. Preservation of low slice emittance in bunch compressors

    Directory of Open Access Journals (Sweden)

    S. Bettoni

    2016-03-01

    Full Text Available Minimizing the dilution of the electron beam emittance is crucial for the performance of accelerators, in particular for free electron laser facilities, where the length of the machine and the efficiency of the lasing process depend on it. Measurements performed at the SwissFEL Injector Test Facility revealed an increase in slice emittance after compressing the bunch even for moderate compression factors. The phenomenon was experimentally studied by characterizing the dependence of the effect on beam and machine parameters relevant for the bunch compression. The reproduction of these measurements in simulation required the use of a 3D beam dynamics model along the bunch compressor that includes coherent synchrotron radiation. Our investigations identified transverse effects, such as coherent synchrotron radiation and transverse space charge as the sources of the observed emittance dilution, excluding other effects, such as chromatic effects on single slices or spurious dispersion. We also present studies, both experimental and simulation based, on the effect of the optics mismatch of the slices on the variation of the slice emittance along the bunch. After a corresponding reoptimization of the beam optics in the test facility we reached slice emittances below 200 nm for the central slices along the longitudinal dimension with a moderate increase up to 300 nm in the head and tail for a compression factor of 7.5 and a bunch charge of 200 pC, equivalent to a final current of 150 A, at about 230 MeV energy.

  6. Low Emittance Guns for the ILC Polarized Electron Beam

    International Nuclear Information System (INIS)

    Clendenin, J.E.; Brachmann, A.; Ioakeimidi, K.; Kirby, R.E.; Maruyama, T.; Miller, R.H.; Wang, J.W.; Zhou, F.; SLAC

    2006-01-01

    Polarized electron beams generated by DC guns are routinely available at several accelerators including JLAB, Mainz and SLAC. These guns operate with a cathode bias on the order of -100 kV. To minimize space charge effects, relatively long bunches are generated at the gun and then compressed longitudinally external to the gun just before and during initial acceleration. For linear colliders, this compression is accomplished using a combination of rf bunchers. For the basic design of the International Linear Collider (ILC), a 120 kV DC photocathode gun is used to produce a series of nanosecond bunches that are each compressed by two sub-harmonic bunchers (SHBs) followed by an L-band buncher and capture section. The longitudinal bunching process results in a significantly higher emittance than produced by the gun alone. While high-energy experiments using polarized beams are not generally sensitive to the source emittance, there are several benefits to a lower source emittance including a simpler more efficient injector system and a lower radiation load during transport especially at bends as at the damping ring. For the ILC, the SHBs could be eliminated if the voltage of the gun is raised sufficiently. Simulations using the General Particle Tracer (GPT) package indicate that a cathode bias voltage of (ge)200 kV should allow both SHBs to be operated at 433 or even 650 MHz, while (ge)500 kV would be required to eliminate the SHBs altogether. Simulations can be used to determine the minimum emittance possible if the injector is designed for a given increased voltage. A possible alternative to the DC gun is an rf gun. Emittance compensation, routinely used with rf guns, is discussed for higher-voltage DC guns

  7. Track counting in radon dosimetry

    International Nuclear Information System (INIS)

    Fesenbeck, Ingo; Koehler, Bernd; Reichert, Klaus-Martin

    2013-01-01

    The newly developed, computer-controlled track counting system is capable of imaging and analyzing the entire area of nuclear track detectors. The high optical resolution allows a new analysis approach for the process of automated counting using digital image processing technologies. This way, higher exposed detectors can be evaluated reliably by an automated process as well. (orig.)

  8. On the design guideline for the low emittance synchrotron radiation source

    International Nuclear Information System (INIS)

    Kamiya, Y.; Kihara, M.

    1983-09-01

    In this note we will describe how the emittance of the electron storage ring is determined by the orbit parameters of the storage ring and show the lowest value of emittance which is achieved theoretically. Implication of this note with regard to the design of the low emittance storage ring will be discussed. (author)

  9. Galaxy number counts: Pt. 2

    International Nuclear Information System (INIS)

    Metcalfe, N.; Shanks, T.; Fong, R.; Jones, L.R.

    1991-01-01

    Using the Prime Focus CCD Camera at the Isaac Newton Telescope we have determined the form of the B and R galaxy number-magnitude count relations in 12 independent fields for 21 m ccd m and 19 m ccd m 5. The average galaxy count relations lie in the middle of the wide range previously encompassed by photographic data. The field-to-field variation of the counts is small enough to define the faint (B m 5) galaxy count to ±10 per cent and this variation is consistent with that expected from galaxy clustering considerations. Our new data confirm that the B, and also the R, galaxy counts show evidence for strong galaxy luminosity evolution, and that the majority of the evolving galaxies are of moderately blue colour. (author)

  10. Hanford whole body counting manual

    International Nuclear Information System (INIS)

    Palmer, H.E.; Brim, C.P.; Rieksts, G.A.; Rhoads, M.C.

    1987-05-01

    This document, a reprint of the Whole Body Counting Manual, was compiled to train personnel, document operation procedures, and outline quality assurance procedures. The current manual contains information on: the location, availability, and scope of services of Hanford's whole body counting facilities; the administrative aspect of the whole body counting operation; Hanford's whole body counting facilities; the step-by-step procedure involved in the different types of in vivo measurements; the detectors, preamplifiers and amplifiers, and spectroscopy equipment; the quality assurance aspect of equipment calibration and recordkeeping; data processing, record storage, results verification, report preparation, count summaries, and unit cost accounting; and the topics of minimum detectable amount and measurement accuracy and precision. 12 refs., 13 tabs

  11. Imaging of Homeostatic, Neoplastic, and Injured Tissues by HA-Based Probes

    Science.gov (United States)

    Veiseh, Mandana; Breadner, Daniel; Ma, Jenny; Akentieva, Natalia; Savani, Rashmin C; Harrison, Rene; Mikilus, David; Collis, Lisa; Gustafson, Stefan; Lee, Ting-Yim; Koropatnick, James; Luyt, Leonard G.; Bissell, Mina J.; Turley, Eva A.

    2013-01-01

    An increase in hyaluronan (HA) synthesis, cellular uptake, and metabolism occurs during the remodeling of tissue microenvironments following injury and during disease processes such as cancer. We hypothesized that multimodality HA-based probes selectively target and detectably accumulate at sites of high HA metabolism, thus providing a flexible imaging strategy for monitoring disease and repair processes. Kinetic analyses confirmed favorable available serum levels of the probe following intravenous (i.v.) or subcutaneous (s.c.) injection. Nuclear (technetium-HA, 99mTc-HA, and iodine-HA, 125I-HA), optical (fluorescent Texas Red-HA, TR-HA), and magnetic resonance (gadolinium-HA, Gd-HA) probes imaged liver (99mTc-HA), breast cancer cells/xenografts (TR-HA, Gd-HA), and vascular injury (125I-HA, TR-HA). Targeting of HA probes to these sites appeared to result from selective HA receptor-dependent localization. Our results suggest that HA-based probes, which do not require polysaccharide backbone modification to achieve favorable half-life and distribution, can detect elevated HA metabolism in homeostatic, injured, and diseased tissues. PMID:22066590

  12. Poredbena analiza Haških i Roterdamskih pravila

    Directory of Open Access Journals (Sweden)

    Vesna Skorupan Wolff

    2010-12-01

    Full Text Available Primjenom komparativne metode uspoređuju se najvažnije konvencijske odredbe i rješenja Roterdamskih pravila s onima sadržanim u Haškim pravilima. Raščlanjuje se većina recentnih odredbi Roterdamskih pravila koje predstavljaju ključne elemente po kojime se ona razlikuju od Haških pravila. U okviru toga ukazuje se na važnost novih pojmova, instituta i osoba koje sudjeluju u prijevoznom poslu. Govori se i o važnim odredbama koje su podudarne jer upravo brojna tradicionalna rješenja koja donose Roterdamska pravila mogu pridonijeti njihovom bržem i lakšem akceptiranju. Roterdamska pravila nastoje na suvremeni način urediti ugovore o prijevozu stvari morem, a pod određenim uvjetima primjenjivat će se i na prijevoze drugim prijevoznim granama. Opsežnost konvencije govori o njezinoj sveobuhvatnosti i velikoj preciznosti u propisivanju gotovo svih pitanja iz područja pravnog uređenja pomorskih prijevoznih ugovora, i više od toga, ona je jedinstven primjer temeljite raščlambe svih obveza i odgovornosti ugovornih stranaka i općenito svih subjekata koji se pojavljuju u prijevoznom poslu. Cilj poredbene analize Haških i Roterdamskih pravila je spoznati što novo donose Roterdamska pravila i procijeniti kako se ona uklapaju u postojeće pravno uređenje prijevoza stvari morem. Istodobno cilj je spoznati koje se odredbe Haških pravila danas izlažu kritici zbog njihove neprilagođenosti suvremenim uvjetima prijevoza i novim i drugačijim odnosima snaga između ugovornih strana u pomorskim prijevoznim ugovorima.

  13. El griot no ha muerto, viva el hip-hop

    Directory of Open Access Journals (Sweden)

    Fco. Javier González García-Mamely

    2015-11-01

    Full Text Available La oratura en África ha jugado un papel vital a lo largo de los milenios como un (único medio de preservar y transmitir la historia, la cultura y el imaginario de cada comunidad. El griot es un claro modelo de las artes orales, pero ha sufrido cambios drásticos en su modo de vida y en los recursos narrativos de los que dispone. Tras el mecenazgo de los grandes reyes y las sucesivas llegadas del islam, el colonialismo y los procesos de modernización y occidentalización, los griots se han tenido que adaptar a nuevos patrones, audiencias y medios de comunicación, convirtiéndose en políticos o en figuras del espectáculo. La aparición del rap y el hip-hop reclamando ser los “modernos griots” ha ocasionado una respuesta crítica y una atracción viral hacia el nuevo fenómeno, sea éste un nuevo género o una reinvención de la oratura del antiguo griot.

  14. Emittance Measurements from a Laser Driven Electron Injector

    Energy Technology Data Exchange (ETDEWEB)

    Reis, David A

    2003-07-28

    The Gun Test Facility (GTF) at the Stanford Linear Accelerator Center was constructed to develop an appropriate electron beam suitable for driving a short wavelength free electron laser (FEL) such as the proposed Linac Coherent Light Source (LCLS). For operation at a wavelength of 1.5 {angstrom}, the LCLS requires an electron injector that can produce an electron beam with approximately 1 {pi} mm-mrad normalized rms emittance with at least 1 nC of charge in a 10 ps or shorter bunch. The GTF consists of a photocathode rf gun, emittance-compensation solenoid, 3 m linear accelerator (linac), drive laser, and diagnostics to measure the beam. The rf gun is a symmetrized 1.6 cell, s-band high gradient, room temperature, photocathode structure. Simulations show that this gun when driven by a temporally and spatially shaped drive laser, appropriately focused with the solenoid, and further accelerated in linac can produce a beam that meets the LCLS requirements. This thesis describes the initial characterization of the laser and electron beam at the GTF. A convolved measurement of the relative timing between the laser and the rf phase in the gun shows that the jitter is less than 2.5 ps rms. Emittance measurements of the electron beam at 35 MeV are reported as a function of the (Gaussian) pulse length and transverse profile of the laser as well as the charge of the electron beam at constant phase and gradient in both the gun and linac. At 1 nC the emittance was found to be {approx} 13 {pi} mm-mrad for 5 ps and 8 ps long laser pulses. At 0.5 nC the measured emittance decreased approximately 20% in the 5 ps case and 40% in the 8 ps case. These measurements are between 40-80% higher than simulations for similar experimental conditions. In addition, the thermal emittance of the electron beam was measured to be 0.5 {pi} mm-mrad.

  15. Methodology for estimation of 32P in bioassay samples by Cerenkov counting

    International Nuclear Information System (INIS)

    Wankhede, Sonal; Sawant, Pramilla D.; Yadav, R.K.B.; Rao, D.D.

    2016-01-01

    Radioactive phosphorus ( 32 P) as phosphate is used to effectively reduce bone pain in terminal cancer patients. Several hospitals in India carry out this palliative care procedure on a regular basis. Thus, production as well as synthesis of 32 P compounds has increased over the years to meet this requirement. Monitoring of radiation workers handling 32 P compounds is important for further strengthening of radiological protection program at processing facility. 32 P being a pure beta emitter (β max = 1.71 MeV, t 1/2 = 14.3 d), bioassay is the preferred individual monitoring technique. Method standardized at Bioassay Lab, Trombay, includes estimation of 32 P in urine by co-precipitation with ammonium phosphomolybdate (AMP) followed by gross beta counting. In the present study, feasibility of Cerenkov counting for detection of 32 P in bioassay samples was explored and the results obtained were compared with the gross beta counting technique

  16. Calibration of nuclides by gamma-gamma sum peak coincidence counting

    International Nuclear Information System (INIS)

    Guevara, E.A.

    1986-01-01

    The feasibility of extending sum peak coincidence counting to the direct calibration of gamma-ray emitters having particular decay schemes was investigated, also checkings of the measurement accuracy, by comparing with more precise beta-gamma coincidence counting have been performed. New theoretical studies and experiments were developed, demonstrating the reliability of the procedure. Uncertainties of less than one percent were obtained when certain radioactive sources were measured. The application of the procedure to 60 Co, 22 Na, 47 Ca and 148 Pm was studied. Theoretical bases of sum peak coincidence counting were set in order to extend it as an alternative method for absolute activity determination. In this respect, theoretical studies were performed for positive and negative beta decay, and electron capture, either accompanied or unaccompanied by coincident gamma rays. They include decay schemes containing up to three daughter nuclide excited levels, for different geometrical configurations. Equations are proposed for a possible generalization of the procedure. (M.E.L.) [es

  17. Experimental Study of Coherent Synchrotron Radiation in the Emittance Exchange Line at the A0-Photoinjector

    Science.gov (United States)

    Thangaraj, Jayakar C. T.; Thurman-Keup, R.; Johnson, A.; Lumpkin, A. H.; Edwards, H.; Ruan, J.; Santucci, J.; Sun, Y. E.; Church, M.; Piot, P.

    2010-11-01

    Next generation accelerators will require a high current, low emittance beam with a low energy spread. Such accelerators will employ advanced beam conditioning systems such as emittance exchangers to manipulate high brightness beams. One of the goals of the Fermilab A0 photoinjector is to investigate the transverse to longitudinal emittance exchange principle. Coherent synchrotron radiation could limit high current operation of the emittance exchanger. In this paper, we report on the preliminary experimental and simulation study of the coherent synchroton radiation (CSR) in the emittance exchange line at the A0 photoinjector.

  18. In vivo counting of uranium

    International Nuclear Information System (INIS)

    Palmer, H.E.

    1985-03-01

    A state-of-the-art radiation detector system consisting of six individually mounted intrinsic germanium planar detectors, each 20 cm 2 by 13 mm thick, mounted together such that the angle of the whole system can be changed to match the slope of the chest of the person being counted, is described. The sensitivity of the system for counting uranium and plutonium in vivo and the precedures used in calibrating the system are also described. Some results of counts done on uranium mill workers are presented. 15 figs., 2 tabs

  19. Monte Carlo Transverse Emittance Study on Cs2Te

    CERN Document Server

    Banfi, F; Galimberti, P G; Giannetti, C; Pagliara, S; Parmigiani, F; Pedersoli, E

    2005-01-01

    A Monte Carlo study of electron transport in Cs2Te films is performed to investigate the transverse emittance epsilon at the cathode surface. We find the photoemitted electron angular distribution and explain the physical mechanism involved in the process, a mechanism hindered by the statistical nature of the Monte Carlo method. The effects of electron-phonon scattering are discussed. The transverse emittance is calculated for different radiation wavelengths and a laser spot size of 1.5*10(-3) m. For a laser radiation at 265 nm we find epsilon = 0.56 mm-mrad. The dependence of epsilon and the quantum yield on the electron affinity Ea is also investigated. The data shows the importance of aging/contamination on the material.

  20. Low emittance optics of photon factory storage ring at KEK

    International Nuclear Information System (INIS)

    Kamiya, Y.; Katoh, M.; Honjo, I.; Araki, A.; Kihara, M.

    1987-01-01

    A new optics is being successfully tested at the Photon Factory Storage Ring (PF-RING) in order to reduce the emittance to 0.13 mm mrad, about one third of the present value. This optics with four additional quadrupole magnets is a modified version of one of the optics designed as an option at the early period of PF construction. One advantage of this new optics is that the beta-function at RF-sections is smaller than that of the old option. The other advantage is that the dispersion function is zero at the long straight sections for insertion devices and RF cavities. The aim of this paper is to describe the new low-emittance optics as well as the parameters of the new quadrupole magnets and power supplies. Some preliminary results of machine study are also presented

  1. Emittance preservation during bunch compression with a magnetized beam

    Energy Technology Data Exchange (ETDEWEB)

    Stratakis, Diktys [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2015-09-02

    The deleterious effects of coherent synchrotron radiation (CSR) on the phase-space and energy spread of high-energy beams in accelerator light sources can significantly constrain the machine design and performance. In this paper, we present a simple method to preserve the beam emittance by means of using magnetized beams that exhibit a large aspect ratio on their transverse dimensions. The concept is based on combining a finite solenoid field where the beam is generated together with a special optics adapter. Numerical simulations of this new type of beam source show that the induced phase-space density growth can be notably suppressed to less than 1% for any bunch charge. This work elucidates the key parameters that are needed for emittance preservation, such as the required field and aspect ratio for a given bunch charge.

  2. Nanodiamond composite as a material for cold electron emitters

    International Nuclear Information System (INIS)

    Arkhipov, A V; Sominski, G G; Uvarov, A A; Gordeev, S K; Korchagina, S B

    2008-01-01

    Characteristics of field-induced electron emission were investigated for one of newly designed all-carbon materials - nanodiamond composite (NDC). The composite is comprised by 4-6 nm diamond grains covered with 0.2-1 nm-thick graphite-like shells that merge at grain junctions and determine such properties as mechanical strength and high electric conductivity. Large number of uniformly distributed sp 3 -sp 2 interfaces allowed to expect enhanced electron emission in electric field. Combination of these features makes NDC a promising material for cold electron emitters in various applications. Experimental testing confirmed high efficiency of electron emission from NDC. In comparison with previousely tested forms of nanocarbon, NDC emitters demonstrated better stabily and tolerance to performance conditions. Unusual activation scenarios and thermal dependencies of emission characteristics observed in experiments with NDC can add new background for explanation of facilitated electron emission from nanocarbons with relatively 'smooth' surface morphology

  3. Emittance Correction in the 2006 ILC Bunch Compressor

    International Nuclear Information System (INIS)

    Tenenbaum, P.; SLAC

    2007-01-01

    A recent study [1] has indicated substantial potential emittance growth in the ILC bunch compressor due to quad misalignments, BPM misalignments, and pitches in the RF cavities. Table 1 summarizes several results from [1]. In this simulation, quad misalignments and cavity pitches are Gaussian distributed and are considered with respect to the nominal survey line; BPM misalignments are also Gaussian-distributed but are considered with respect to the quadrupole axis. It is assumed that the BPM offsets with respect to the quads are found in a previous quad-shunting BBA step which is not simulated. In this study we seek to repeat the studies documented above, and additionally to perform a study in which additional dispersion bumps are used to further reduce the projected emittance

  4. Generalized emittance measurements in a beam transport line

    International Nuclear Information System (INIS)

    Skelly, J.; Gardner, C.; Luccio, A.; Kponou, A.; Reece, K.

    1991-01-01

    Motivated by the need to commission 3 beam transport lines for the new AGS Booster project, we have developed a generalized emittance-measurement program; beam line specifics are entirely resident in data tables, not in program code. For instrumentation, the program requires one or more multi-wire profile monitors; one or multiple profiles are acquired from each monitor, corresponding to one or multiple tunes of the transport line. Emittances and Twiss parameters are calculated using generalized algorithms. The required matix descriptions of the beam optics are constructed by an on-line general beam modeling program. Design of the program, its algorithms, and initial experience with it will be described. 4 refs., 2 figs., 1 tab

  5. Rose, a rotating system for 4D emittance measurements

    Energy Technology Data Exchange (ETDEWEB)

    Maier, Michael; Groening, Lars; Xiao, Chen; Mickat, Sascha; Du, Xiaonan; Gerhard, Peter; Vormann, Hartmut [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH (Germany)

    2016-07-01

    A ROtating System for Emittance measurements ROSE, to measure the full 4 dimensional transverse beam matrix of a heavy ion beam has been developed and commissioned. Different heavy ion beams behind the HLI at GSI have been used in two commissioning beam times. All technical aspects of Rose have been tested, Rose has been benchmarked against existing emittance scanners for horizontal and vertical projections and the method, hard- and software to measure the 4D beam matrix has been upgraded, refined and successfully commissioned. The inter plane correlations of the HLI beam have been measured, yet as no significant initial correlations were found to be present, controlled coupling of the beam by using a skew triplet has been applied and confirmed with Rose. The next step is to use ROSE to measure and remove the known inter plane correlations of a Uranium beam before SIS18 injection.

  6. Tellurium adsorption on tungsten and molybdenum field emitters

    International Nuclear Information System (INIS)

    Collins, R.A.; Kiwanga, C.A.

    1977-01-01

    Studies of the adsorption of tellurium onto tungsten and molybdenum field emitters are described and the results obtained are compared with those obtained in previous work on the adsorption of silicon and selenium. The adsorption of Te onto W was found to be much more uniform than in the case of Se. Although Te is metallic in many of its properties its adsorptive behavior on field emitters is found to be similar to that of selenium and these adsorptive properties are basically common to all semiconductors. The most evident property of these adsorbates is that the work function and emission current decrease simultaneously at coverages of less than half a monolayer and the work function subsequently increases. (B.D.)

  7. Electron Cloud at Low Emittance in CesrTA

    CERN Document Server

    Palmer, Mark; Billing, Michael; Calvey, Joseph; Conolly, Christopher; Crittenden, James; Dobbins, John; Dugan, Gerald; Eggert, Nicholas; Fontes, Ernest; Forster, Michael; Gallagher, Richard; Gray, Steven; Greenwald, Shlomo; Hartill, Donald; Hopkins, Walter; Kreinick, David; Kreis, Benjamin; Leong, Zhidong; Li, Yulin; Liu, Xianghong; Livezey, Jesse; Lyndaker, Aaron; Makita, Junki; McDonald, Michael; Medjidzade, Valeri; Meller, Robert; O'Connell, Tim; Peck, Stuart; Peterson, Daniel; Ramirez, Gabriel; Rendina, Matthew; Revesz, Peter; Rider, Nate; Rice, David; Rubin, David; Sagan, David; Savino, James; Schwartz, Robert; Seeley, Robert; Sexton, James; Shanks, James; Sikora, John; Smith, Eric; Strohman, Charles; Williams, Heather; Antoniou, Fanouria; Calatroni, Sergio; Gasior, Marek; Jones, Owain Rhodri; Papaphilippou, Yannis; Pfingstner, Juergen; Rumolo, Giovanni; Schmickler, Hermann; Taborelli, Mauro; Asner, David; Boon, Laura; Garfinkel, Arthur; Byrd, John; Celata, Christine; Corlett, John; De Santis, Stefano; Furman, Miguel; Jackson, Alan; Kraft, Rick; Munson, Dawn; Penn, Gregory; Plate, David; Venturini, Marco; Carlson, Benjamin; Demma, Theo; Dowd, Rohan; Flanagan, John; Jain, Puneet; Kanazawa, Ken-ichi; Kubo, Kiyoshi; Ohmi, Kazuhito; Sakai, Hiroshi; Shibata, Kyo; Suetsugu, Yusuke; Tobiyama, Makoto; Gonnella, Daniel; Guo, Weiming; Harkay, Katherine; Holtzapple, Robert; Jones, James; Wolski, Andrzej; Kharakh, David; Ng, Johnny; Pivi, Mauro; Wang, Lanfa; Ross, Marc; Tan, Cheng-Yang; Zwaska, Robert; Schachter, Levi; Wilkinson, Eric

    2010-01-01

    The Cornell Electron Storage Ring (CESR) has been reconfigured as a test accelerator (CesrTA) for a program of electron cloud (EC) research at ultra low emittance. The instrumentation in the ring has been upgraded with local diagnostics for measurement of cloud density and with improved beam diagnostics for the characterization of both the low emittance performance and the beam dynamics of high intensity bunch trains interacting with the cloud. A range of EC mitigation methods have been deployed and tested and their effectiveness is discussed. Measurements of the electron cloud’s effect on the beam under a range of conditions are discussed along with the simulations being used to quantitatively understand these results

  8. Emittance preservation during bunch compression with a magnetized beam

    Energy Technology Data Exchange (ETDEWEB)

    Stratakis, Diktys

    2016-03-01

    The deleterious effects of coherent synchrotron radiation (CSR) on the phase-space and energy spread of high-energy beams in accelerator light sources can significantly constrain the machine design and performance. In this paper, we present a simple method to preserve the beam emittance by means of using magnetized beams that exhibit a large aspect ratio on their transverse dimensions. The concept is based in combining a finite solenoid field where the beam is generated with a special optics adapter. Numerical simulations of this new type of beam source show that the induced phase-space density growth from CSR can be notably suppressed to less than 1% for any bunch charge. This work elucidates the key parameters that are needed for emittance preservation, such as the required field and aspect ratio for a given bunch charge.

  9. Nanodiamond composite as a material for cold electron emitters

    Energy Technology Data Exchange (ETDEWEB)

    Arkhipov, A V; Sominski, G G; Uvarov, A A [St.Petersburg State Polytechnic University, 29 Politchnicheskaya, St.Petersburg, 195251 (Russian Federation); Gordeev, S K; Korchagina, S B [FSUE ' Central Research Institute for Materials' , 8 Paradnaya Street, St.Petersburg, 191014 (Russian Federation)], E-mail: arkhipov@rphf.spbstu.ru

    2008-03-15

    Characteristics of field-induced electron emission were investigated for one of newly designed all-carbon materials - nanodiamond composite (NDC). The composite is comprised by 4-6 nm diamond grains covered with 0.2-1 nm-thick graphite-like shells that merge at grain junctions and determine such properties as mechanical strength and high electric conductivity. Large number of uniformly distributed sp{sup 3}-sp{sup 2} interfaces allowed to expect enhanced electron emission in electric field. Combination of these features makes NDC a promising material for cold electron emitters in various applications. Experimental testing confirmed high efficiency of electron emission from NDC. In comparison with previousely tested forms of nanocarbon, NDC emitters demonstrated better stabily and tolerance to performance conditions. Unusual activation scenarios and thermal dependencies of emission characteristics observed in experiments with NDC can add new background for explanation of facilitated electron emission from nanocarbons with relatively 'smooth' surface morphology.

  10. Emittance growth in non-symmetric beam configurations

    International Nuclear Information System (INIS)

    Anderson, O.A.

    1996-06-01

    Emittance growth in intense beams due to nonuniformity, mismatch, and misalignment has been analyzed by Reiser for the special case of axisymmetry. A more complex problem occurs in cases where a number of discrete beamlets are to be merged into a single focusing channel, for example, in designs for Heavy Ion Fusion drivers or Magnetic Fusion negative-ion systems. Celata, assuming the system to be perfectly matched and aligned, analyzed the case of four round beamlets arranged in a square array. We generalize these previous studies and analyze emittance growth in systems that are less symmetric. We include beam systems that are not necessarily matched and where the x and y moments may be unequal. We also include the possibility of initial convergence velocities that may differ in the two planes and allow for misalignment of the beam center-of-mass position and direction

  11. The HaDREB2 transcription factor enhances basal thermotolerance and longevity of seeds through functional interaction with HaHSFA9

    Directory of Open Access Journals (Sweden)

    Carranco Raúl

    2009-06-01

    Full Text Available Abstract Background Transcription factor HaDREB2 was identified in sunflower (Helianthus annuus L. as a drought-responsive element-binding factor 2 (DREB2 with unique properties. HaDREB2 and the sunflower Heat Shock Factor A9 (HaHSFA9 co-activated the Hahsp17.6G1 promoter in sunflower embryos. Both factors could be involved in transcriptional co-activation of additional small heat stress protein (sHSP promoters, and thus contribute to the HaHSFA9-mediated enhancement of longevity and basal thermotolerance of seeds. Results We found that overexpression of HaDREB2 in seeds did not enhance longevity. This was deduced from assays of basal thermotolerance and controlled seed-deterioration, which were performed with transgenic tobacco. Furthermore, the constitutive overexpression of HaDREB2 did not increase thermotolerance in seedlings or result in the accumulation of HSPs at normal growth temperatures. In contrast, when HaDREB2 and HaHSFA9 were conjointly overexpressed in seeds, we observed positive effects on seed longevity, beyond those observed with overexpression of HaHSFA9 alone. Such additional effects are accompanied by a subtle enhancement of the accumulation of subsets of sHSPs belonging to the CI and CII cytosolic classes. Conclusion Our results reveal the functional interdependency of HaDREB2 and HaHSFA9 in seeds. HaDREB2 differs from other previously characterized DREB2 factors in plants in terms of its unique functional interaction with the seed-specific HaHSFA9 factor. No functional interaction between HaDREB2 and HaHSFA9 was observed when both factors were conjointly overexpressed in vegetative tissues. We therefore suggest that additional, seed-specific factors, or protein modifications, could be required for the functional interaction between HaDREB2 and HaHSFA9.

  12. Complete Blood Count (For Parents)

    Science.gov (United States)

    ... Kids Deal With Injections and Blood Tests Blood Culture Anemia Blood Test: Basic Metabolic Panel (BMP) Blood Test: Hemoglobin Basic Blood Chemistry Tests Word! Complete Blood Count (CBC) Medical Tests and Procedures ( ...

  13. Make My Trip Count 2015

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — The Make My Trip Count (MMTC) commuter survey, conducted in September and October 2015 by GBA, the Pittsburgh 2030 District, and 10 other regional transportation...

  14. Counting Triangles to Sum Squares

    Science.gov (United States)

    DeMaio, Joe

    2012-01-01

    Counting complete subgraphs of three vertices in complete graphs, yields combinatorial arguments for identities for sums of squares of integers, odd integers, even integers and sums of the triangular numbers.

  15. From classical to quantum plasmonics: Classical emitter and SPASER

    Science.gov (United States)

    Balykin, V. I.

    2018-02-01

    The key advantage of plasmonics is in pushing our control of light down to the nanoscale. It is possible to envision lithographically fabricated plasmonic devices for future quantum information processing or cryptography at the nanoscale in two dimensions. A first step in this direction is a demonstration of a highly efficient nanoscale light source. Here we demonstrate two types of nanoscale sources of optical fields: 1) the classical metallic nanostructure emitter and 2) the plasmonic nanolaser - SPASER.

  16. A program to research emittance growth in bends

    International Nuclear Information System (INIS)

    Bohn, C.L.

    1995-01-01

    A research program to explore the phenomenon of emittance growth in bends due to noninertial space-charge effects has been defined and initiated. The program combines theoretical, numerical, and experimental investigations. This paper summarizes the motivation of the work and highlights CEBAF's need for immediate results. The program's key elements, some of which qualitatively differ from the standard approach used to investigate the production and effects of coherent synchrotron radiation in synchrotrons and storage rings, are enumerated and discussed. 1 fig

  17. Interconnection network architectures based on integrated orbital angular momentum emitters

    Science.gov (United States)

    Scaffardi, Mirco; Zhang, Ning; Malik, Muhammad Nouman; Lazzeri, Emma; Klitis, Charalambos; Lavery, Martin; Sorel, Marc; Bogoni, Antonella

    2018-02-01

    Novel architectures for two-layer interconnection networks based on concentric OAM emitters are presented. A scalability analysis is done in terms of devices characteristics, power budget and optical signal to noise ratio by exploiting experimentally measured parameters. The analysis shows that by exploiting optical amplifications, the proposed interconnection networks can support a number of ports higher than 100. The OAM crosstalk induced-penalty, evaluated through an experimental characterization, do not significantly affect the interconnection network performance.

  18. Cancer therapy with alpha-emitters labeled peptides.

    Science.gov (United States)

    Dadachova, Ekaterina

    2010-05-01

    Actively targeted alpha-particles offer specific tumor cell killing action with less collateral damage to surrounding normal tissues than beta-emitters. During the last decade, radiolabeled peptides that bind to different receptors on the tumors have been investigated as potential therapeutic agents both in the preclinical and clinical settings. Advantages of radiolabeled peptides over antibodies include relatively straightforward chemical synthesis, versatility, easier radiolabeling, rapid clearance from the circulation, faster penetration and more uniform distribution into tissues, and less immunogenicity. Rapid internalization of the radiolabeled peptides with equally rapid re-expression of the cell surface target is a highly desirable property that enhances the total delivery of these radionuclides into malignant sites. Peptides, such as octreotide, alpha-melanocyte-stimulating hormone analogues, arginine-glycine-aspartic acid-containing peptides, bombesin derivatives, and others may all be feasible for use with alpha-emitters. The on-going preclinical work has primarily concentrated on octreotide and octreotate analogues labeled with Bismuth-213 and Astatine-211. In addition, alpha-melanocyte-stimulating hormone analogue has been labeled with Lead-212/Bismuth-212 in vivo generator and demonstrated the encouraging therapeutic efficacy in treatment of experimental melanoma. Obstacles that continue to obstruct widespread acceptance of alpha-emitter-labeled peptides are primarily the supply of these radionuclides and concerns about potential kidney toxicity. New sources and methods for production of these medically valuable radionuclides and better understanding of mechanisms related to the peptide renal uptake and clearance should speed up the introduction of alpha-emitter-labeled peptides into the clinic. Copyright 2010 Elsevier Inc. All rights reserved.

  19. Device for the radiation centering at electron emitters

    International Nuclear Information System (INIS)

    Panzer, S.; Ardenne, T. von; Jessat, K.; Bahr, G.

    1985-01-01

    The invention has been directed at a device for a simplified and reliable centering of electron beams at electron emitters in particular for welding and thermal surface modifications. The electron beam has been focussed relatively to an electron-optical lens. A movable masked electron detector has been arranged at the electron beam deflection plane. The electron detector is connected with an electronic data evaluation equipment

  20. Industrial application of electron sources with plasma emitters

    CERN Document Server

    Belyuk, S I; Rempe, N G

    2001-01-01

    Paper contains a description, operation, design and parameters of electron sources with plasma emitters. One presents examples of application of these sources as part of automated electron-beam welding lines. Paper describes application of such sources for electron-beam deposition of composite powders. Electron-beam deposition is used to rebuild worn out part and to increase strength of new parts of machines and tools. Paper presents some examples of rebuilding part and the advantages gained in this case

  1. Multi-gated field emitters for a micro-column

    International Nuclear Information System (INIS)

    Mimura, Hidenori; Kioke, Akifumi; Aoki, Toru; Neo, Yoichiro; Yoshida, Tomoya; Nagao, Masayoshi

    2011-01-01

    We have developed a multi-gated field emitter (FE) such as a quadruple-gated FE with a three-stacked electrode lens and a quintuple-gated FE with a four-stacked electrode lens. Both the FEs can focus the electron beam. However, the quintuple-gated FE has a stronger electron convergence than the quadruple-gated FE, and a beam crossover is clearly observed for the quintuple-gated FE.

  2. Wire scanner data analysis for the SSC Linac emittance measurement

    International Nuclear Information System (INIS)

    Yao, C.Y.; Hurd, J.W.; Sage, J.

    1993-07-01

    The wire scanners are designed in the SSC Linac for measurement of beam emittance at various locations. In order to obtain beam parameters from the scan signal, a data analysis program was developed that considers the problems of noise reduction, machine modeling, parameter fitting, and correction. This program is intended as a tool for Linac commissioning and also as part of the Linac control program. Some of the results from commissioning runs are presented

  3. Counting Word Frequencies with Python

    Directory of Open Access Journals (Sweden)

    William J. Turkel

    2012-07-01

    Full Text Available Your list is now clean enough that you can begin analyzing its contents in meaningful ways. Counting the frequency of specific words in the list can provide illustrative data. Python has an easy way to count frequencies, but it requires the use of a new type of variable: the dictionary. Before you begin working with a dictionary, consider the processes used to calculate frequencies in a list.

  4. Liquid scintillation counting of chlorophyll

    International Nuclear Information System (INIS)

    Fric, F.; Horickova, B.; Haspel-Horvatovic, E.

    1975-01-01

    A precise and reproducible method of liquid scintillation counting was worked out for measuring the radioactivity of 14 C-labelled chlorophyll a and chlorophyll b solutions without previous bleaching. The spurious count rate caused by luminescence of the scintillant-chlorophyll system is eliminated by using a suitable scintillant and by measuring the radioactivity at 4 to 8 0 C after an appropriate time of dark adaptation. Bleaching of the chlorophyll solutions is necessary only for measuring of very low radioactivity. (author)

  5. Impact of water temperature and structural parameters on the hydraulic labyrinth-channel emitter performance

    Directory of Open Access Journals (Sweden)

    Ahmed I. Al-Amoud

    2014-06-01

    Full Text Available The effects of water temperature and structural parameters of a labyrinth emitter on drip irrigation hydraulic performance were investigated. The inside structural parameters of the trapezoidal labyrinth emitter include path width (W and length (L, trapezoidal unit numbers (N, height (H, and spacing (S. Laboratory experiments were conducted using five different types of labyrinth-channel emitters (three non-pressure compensating and two pressure-compensating emitters commonly used for subsurface drip irrigation systems. The water temperature effect on the hydraulic characteristics at various operating pressures was recorded and a comparison was made to identify the most effective structural parameter on emitter performance. The pressure compensating emitter flow exponent (x average was 0.014, while non-pressure compensating emitter’s values average was 0.456, indicating that the sensitivity of non-pressure compensating emitters to pressure variation is an obvious characteristic (p<0.001 of this type of emitters. The effects of water temperature on emitter flow rate were insignificant (p>0.05 at various operating pressures, where the flow rate index values for emitters were around one. The effects of water temperature on manufacturer’s coefficient of variation (CV values for all emitters were insignificant (p>0.05. The CV values of the non-pressure compensating emitters were lower than those of pressure compensating emitters. This is typical for most compensating models because they are manufactured with more elements than non-compensating emitters are. The results of regression analysis indicate that N and H are the essential factors (p<0.001 to affect the hydraulic performance.

  6. Biologic data, models, and dosimetric methods for internal emitters

    International Nuclear Information System (INIS)

    Weber, D.A.

    1990-01-01

    The absorbed radiation dose from internal emitters has been and will remain a pivotal factor in assessing risk and therapeutic utility in selecting radiopharmaceuticals for diagnosis and treatment. Although direct measurements of absorbed dose and dose distributions in vivo have been and will continue to be made in limited situations, the measurement of the biodistribution and clearance of radiopharmaceuticals in human subjects and the use of this data is likely to remain the primary means to approach the calculation and estimation of absorbed dose from internal emitters over the next decade. Since several approximations are used in these schema to calculate dose, attention must be given to inspecting and improving the application of this dosimetric method as better techniques are developed to assay body activity and as more experience is gained in applying these schema to calculating absorbed dose. Discussion of the need for considering small scale dosimetry to calculate absorbed dose at the cellular level will be presented in this paper. Other topics include dose estimates for internal emitters, biologic data mathematical models and dosimetric methods employed. 44 refs

  7. Low Emittance Gun Project based on Field Emission

    CERN Document Server

    Ganter, Romain; Dehler, M; Gobrecht, Jens; Gough, Chris; Ingold, Gerhard; Leemann, Simon C; Shing-Bruce-Li, Kevin; Paraliev, Martin; Pedrozzi, Marco; Raguin, Jean Yves; Rivkin, Leonid; Schlott, Volker; Sehr, Harald; Streun, Andreas; Wrulich, Albin F; Zelenika, Sasa

    2004-01-01

    The design of an electron gun capable of producing beam emittance one order of magnitude lower than current technology would reduce considerably the cost and size of a free electron laser emitting at 0.1nm. Field emitter arrays (FEAs) including a gate and a focusing layer are an attractive technology for such high brightness sources. Electrons are extracted from micrometric tips thanks to voltage pulses between gate and tips. The focusing layer should then reduce the initial divergence of each emitted beamlets. This FEA will be inserted in a high gradient diode configuration coupled with a radiofrequency structure. In the diode part very high electric field pulses (several hundreds of MV/m) will limit the degradation of emittance due to space charge effect. This first acceleration will be obtained with high voltage pulses (typically a megavolt in a few hundred of nanoseconds) synchronized with the low voltage pulses applied to the FEA (typically one hundred of volts in one nanosecond at frequency below kilohe...

  8. Transverse emittance studies of an induction accelerator of heavy ions

    International Nuclear Information System (INIS)

    Garvey, T.; Eylon, S.; Fessenden, T.J.; Hahn, K.; Henestroza, E.

    1991-01-01

    Current amplification of heavy ion beams is an integral feature of the induction linac approach to heavy ion fusion. As part of the Heavy Ion Fusion Accelerator Research program at LBL the authors have been studying the evolution of the transverse emittance of ion beams while they are undergoing current amplification, achieved by longitudinal bunch compression and acceleration. Experiments are conducted on MBE-4, a four beam Cs + induction linac. The space-charge dominated beams of MBE-4 are focused by electrostatic quadrupoles while they are accelerated from nominally 200 keV up to ∼ 1 MEV by 24 accelerating gaps. Initially the beams have currents of typically 4 mA to 10 mA per beam. Early experimental results showed a growth of the normalized emittance by a factor of 2 while the beam current was amplified by up to 9 times its initial value. The authors will discuss the results of recent experiments in which a mild bunch length compression rate, more typical of that required by a fusion driver, has shown that the normalized emittance can be maintained at its injection value (0.03 mm-mr) during acceleration

  9. Emittance Measurement for Beamline Extension at the PET Cyclotron

    Directory of Open Access Journals (Sweden)

    Sae-Hoon Park

    2016-01-01

    Full Text Available Particle-induced X-ray emission is used for determining the elemental composition of materials. This method uses low-energy protons (of several MeV, which can be obtained from high-energy (of tens MeV accelerators. Instead of manufacturing an accelerator for generating the MeV protons, the use of a PET cyclotron has been suggested for designing the beamline for multipurpose applications, especially for the PIXE experiment, which has a dedicated high-energy (of tens MeV accelerator. The beam properties of the cyclotron were determined at this experimental facility by using an external beamline before transferring the ion beam to the experimental chamber. We measured the beam profile and calculated the emittance using the pepper-pot method. The beam profile was measured as the beam current using a wire scanner, and the emittance was measured as the beam distribution at the beam dump using a radiochromic film. We analyzed the measurement results and are planning to use the results obtained in the simulations of external beamline and aligned beamline components. We will consider energy degradation after computing the beamline simulation. The experimental study focused on measuring the emittance from the cyclotron, and the results of this study are presented in this paper.

  10. Emittance scans for CMS luminosity calibration in 2017

    CERN Document Server

    CMS Collaboration

    2018-01-01

    Emittance scans are short van der Meer type scans performed at the beginning and at the end of LHC fills. The beams are scanned against each other in X and Y planes in 7 displacement steps. These scans are used for LHC diagnostics and since 2017 for a cross check of the CMS luminosity calibration. An XY pair of scans takes around 3 minutes. The BRIL project provides to LHC three independent online luminosity measurement from the Pixel Luminosity Telescope (PLT), the Fast Beam Condition Monitor (BCM1F) and the Forward calorimeter (HF). The excellent performance of the BRIL detector front-ends, fast back-end electronics and CMS XDAQ based data processing and publication allow the use of emittance scans for linearity and stability studies of the luminometers. Emittance scans became a powerful tool and dramatically improved the understanding of the luminosity measurement during the year. Since each luminometer is independently calibrated in every scan the measurements are independent and ratios of luminometers ca...

  11. 1024x1024 resistive emitter array design and fabrication status

    Science.gov (United States)

    Bryant, Paul T.; Oleson, Jim; McHugh, Stephen W.; Beuville, Eric; Schlesselmann, John D.; Woolaway, James T.; Barskey, Steve; Solomon, Steven L.; Joyner, Thomas W.

    2002-07-01

    Santa Barbara Infrared (SBIR) is producing a high performance 1,024 x 1,024 Large Format Resistive emitter Array (LFRA) for use in the next generation of IR Scene Projectors (IRSPs). LFRA requirements were developed through close cooperation with the Tri-Service IR Scene Projector working group, and through detailed trade studies sponsored by the OSD Central T&E Investment Program (CTEIP) and a Phase I US Navy Small Business Innovative Research (SBIR) contract. The CMOS Read-In Integrated Circuit (RIIC) is being designed by SBIR and Indigo Systems under a Small Business Innovative Research (SBIR) contract. Performance and features include 750 K MWIR maximum apparent temperature, 5 ms radiance rise time, 200 Hz full frame update, and 400 Hz window mode operation. Ten 8-inch CMOS wafers will be fabricated and characterized in mid-2002, followed by emitter fabrication in late 2002. This paper discusses array performance, requirements flow-down, array design, fabrication of 2 X 2-inch CMOS devices, and plans for subsequent RIIC wafer test and emitter pixel fabrication.

  12. Fowler Nordheim theory of carbon nanotube based field emitters

    Energy Technology Data Exchange (ETDEWEB)

    Parveen, Shama; Kumar, Avshish [Department of Physics, Jamia Millia Islamia (Central University), New Delhi (India); Husain, Samina [Centre for Nanoscience and Nanotechnology, Jamia Millia Islamia (Central University), New Delhi (India); Husain, Mushahid, E-mail: mush_reslab@rediffmail.com [Department of Physics, Jamia Millia Islamia (Central University), New Delhi (India)

    2017-01-15

    Field emission (FE) phenomena are generally explained in the frame-work of Fowler Nordheim (FN) theory which was given for flat metal surfaces. In this work, an effort has been made to present the field emission mechanism in carbon nanotubes (CNTs) which have tip type geometry at nanoscale. High aspect ratio of CNTs leads to large field enhancement factor and lower operating voltages because the electric field strength in the vicinity of the nanotubes tip can be enhanced by thousand times. The work function of nanostructure by using FN plot has been calculated with reverse engineering. With the help of modified FN equation, an important formula for effective emitting area (active area for emission of electrons) has been derived and employed to calculate the active emitting area for CNT field emitters. Therefore, it is of great interest to present a state of art study on the complete solution of FN equation for CNTs based field emitter displays. This manuscript will also provide a better understanding of calculation of different FE parameters of CNTs field emitters using FN equation.

  13. Energy dependence of the emittance of damping ring beams

    International Nuclear Information System (INIS)

    Stiening, R.

    1985-01-01

    The energy at which the SLC damping rings are operated was chosen to be 1.21 GeV. At the time that that specification was made, the repetition rate of the SLC was expected to be 180 Hz. It is now anticipated that the repetition rate during the initial year of operation of the SLC will be 120 Hz. The following curves which show the output emittance of the damping rings as a function of input emittance and energy suggest that there is a range of energies over which the rings can be operated without changing the SLC luminosity. It should be noted that in the era of polarized beams, the damping ring energy will be fixed at the design value on account of the spin precession required in the LTR and RTL transport lines. The SLC design output emittance of the damping rings is 3 x 10 -5 radian-meters. Because of space charge disruption and quantum emission downstream of the damping rings, much lower values than the design value may not have a large beneficial effect on the luminosity. 3 figures

  14. Photonic emitters and circuits based on colloidal quantum dot composites

    Science.gov (United States)

    Menon, Vinod M.; Husaini, Saima; Valappil, Nikesh; Luberto, Matthew

    2009-02-01

    We discuss our work on light emitters and photonic circuits realized using colloidal quantum dot composites. Specifically we will report our recent work on flexible microcavity laser, microdisk emitters and integrated active - passive waveguides. The entire microcavity laser structure was realized using spin coating and consisted of an all-polymer distributed Bragg reflector with a poly-vinyl carbazole cavity layer embedded with InGaP/ZnS colloidal quantum dots. These microcavities can be peeled off the substrate yielding a flexible structure that can conform to any shape and whose emission spectra can be mechanically tuned. The microdisk emitters and the integrated waveguide structures were realized using soft lithography and photo-lithography, respectively and were fabricated using a composite consisting of quantum dots embedded in SU8 matrix. Finally, we will discuss the effect of the host matrix on the optical properties of the quantum dots using results of steady-state and time-resolved luminescence measurements. In addition to their specific functionalities, these novel device demonstrations and their development present a low cost alternative to the traditional photonic device fabrication techniques.

  15. Superconducting wiggler magnets for beam-emittance damping rings

    CERN Document Server

    Schoerling, Daniel

    2012-01-01

    Ultra-low emittance beams with a high bunch charge are necessary for the luminosity performance of linear electron-positron colliders, such as the Compact Linear Collider (CLIC). An effective way to create ultra-low emittance beams with a high bunch charge is to use damping rings, or storage rings equipped with strong damping wiggler magnets. The remanent field of the permanent magnet materials and the ohmic losses in normal conductors limit the economically achievable pole field in accelerator magnets operated at around room temperature to below the magnetic saturation induction, which is 2.15 T for iron. In wiggler magnets, the pole field in the center of the gap is reduced further like the hyperbolic cosine of the ratio of the gap size and the period length multiplied by pi. Moreover, damping wiggler magnets require relatively large gaps because they have to accept the un-damped beam and to generate, at a small period length, a large magnetic flux density amplitude to effectively damp the beam emittance....

  16. Nanometer emittance ultralow charge beams from rf photoinjectors

    Directory of Open Access Journals (Sweden)

    R. K. Li

    2012-09-01

    Full Text Available In this paper we discuss the generation of a new class of high brightness relativistic electron beams, characterized by ultralow charge (0.1–1 pC and ultralow normalized emittance (<50  nm. These beams are created in rf photoinjectors when the laser is focused on the cathode to very small transverse sizes (<30  μm rms. In this regime, the charge density at the cathode approaches the limit set by the extraction electric field. By shaping the laser pulse to have a cigarlike aspect ratio (the longitudinal dimension much larger than the transverse dimension and a parabolic temporal profile, the resulting space charge dominated dynamics creates a uniformly filled ellipsoidal distribution and the emittance can be nearly preserved to its thermal value. We also present a new method, based on a variation of the pepper-pot technique, for single shot measurements of the ultralow emittances for this new class of beams.

  17. Emittance compensation with dynamically optimized photoelectron beam profiles

    Energy Technology Data Exchange (ETDEWEB)

    Rosenzweig, J.B. [Department of Physics and Astronomy, UCLA, 405 Hilgard Avenue, Los Angeles, CA 90095 (United States)]. E-mail: rosen@physics.ucla.edu; Cook, A.M. [Department of Physics and Astronomy, UCLA, 405 Hilgard Avenue, Los Angeles, CA 90095 (United States); England, R.J. [Department of Physics and Astronomy, UCLA, 405 Hilgard Avenue, Los Angeles, CA 90095 (United States); Dunning, M. [Department of Physics and Astronomy, UCLA, 405 Hilgard Avenue, Los Angeles, CA 90095 (United States); Anderson, S.G. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, CA 94550 (United States); Ferrario, Massimo [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionale di Frascati, Via E. Fermi 41, Frascati, Rome (Italy)

    2006-02-01

    Much of the theory and experimentation concerning creation of a high-brightness electron beam from a photocathode, and then applying emittance compensation techniques, assumes that one must strive for a uniform density electron beam, having a cylindrical shape. On the other hand, this shape has large nonlinearities in the space-charge field profiles near the beam's longitudinal extrema. These nonlinearities are known to produce both transverse and longitudinal emittance growth. On the other hand, it has recently been shown by Luiten that by illuminating the cathode with an ultra-short laser pulse of appropriate transverse profile, a uniform density, ellipsoidally shaped bunch is dynamically formed, which then has linear space-charge fields in all dimensions inside of the bunch. We study here this process, and its marriage to the standard emittance compensation scenario that is implemented in most recent photoinjectors. It is seen that the two processes are compatible, with simulations indicating a very high brightness beam can be obtained. The robustness of this scheme to systematic errors is examined. Prospects for experimental tests of this scheme are discussed.

  18. Emittance compensation with dynamically optimized photoelectron beam profiles

    International Nuclear Information System (INIS)

    Rosenzweig, J.B.; Cook, A.M.; England, R.J.; Dunning, M.; Anderson, S.G.; Ferrario, Massimo

    2006-01-01

    Much of the theory and experimentation concerning creation of a high-brightness electron beam from a photocathode, and then applying emittance compensation techniques, assumes that one must strive for a uniform density electron beam, having a cylindrical shape. On the other hand, this shape has large nonlinearities in the space-charge field profiles near the beam's longitudinal extrema. These nonlinearities are known to produce both transverse and longitudinal emittance growth. On the other hand, it has recently been shown by Luiten that by illuminating the cathode with an ultra-short laser pulse of appropriate transverse profile, a uniform density, ellipsoidally shaped bunch is dynamically formed, which then has linear space-charge fields in all dimensions inside of the bunch. We study here this process, and its marriage to the standard emittance compensation scenario that is implemented in most recent photoinjectors. It is seen that the two processes are compatible, with simulations indicating a very high brightness beam can be obtained. The robustness of this scheme to systematic errors is examined. Prospects for experimental tests of this scheme are discussed

  19. Standardization of 241Am by digital coincidence counting, liquid scintillation counting and defined solid angle counting

    International Nuclear Information System (INIS)

    Balpardo, C.; Capoulat, M.E.; Rodrigues, D.; Arenillas, P.

    2010-01-01

    The nuclide 241 Am decays by alpha emission to 237 Np. Most of the decays (84.6%) populate the excited level of 237 Np with energy of 59.54 keV. Digital coincidence counting was applied to standardize a solution of 241 Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid scintillation counting using the logical sum of double coincidences in a TDCR array and defined solid angle counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.

  20. Biomedical potential of chitosan/HA and chitosan/β-1,3-glucan/HA biomaterials as scaffolds for bone regeneration — A comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Przekora, Agata, E-mail: agata.przekora@umlub.pl [Department of Biochemistry and Biotechnology, Medical University of Lublin, Chodzki 1, 20-093 Lublin (Poland); Palka, Krzysztof [Department of Materials Engineering, Lublin University of Technology, Nadbystrzycka 36, 20-618 Lublin (Poland); Ginalska, Grazyna [Department of Biochemistry and Biotechnology, Medical University of Lublin, Chodzki 1, 20-093 Lublin (Poland)

    2016-01-01

    The aim of this work was to compare biomedical potential of chitosan/hydroxyapatite (chit/HA) and novel chitosan/β-1,3-glucan/hydroxyapatite (chit/glu/HA) materials as scaffolds for bone regeneration via characterization of their biocompatibility, porosity, mechanical properties, and water uptake behaviour. Biocompatibility of the scaffolds was assessed in direct-contact with the materials using normal human foetal osteoblast cell line. Cytotoxicity and osteoblast proliferation rate were evaluated. Porosity was assessed using computed microtomography analysis and mechanical properties were determined by compression testing. Obtained results demonstrated that chit/HA scaffold possessed significantly better mechanical properties (compressive strength: 1.23 MPa, Young's modulus: 0.46 MPa) than chit/glu/HA material (compressive strength: 0.26 MPa, Young's modulus: 0.25 MPa). However, addition of bacterial β-1,3-glucan to the chit/HA scaffold improved its flexibility and porosity. Moreover, chit/glu/HA scaffold revealed significantly higher water uptake capability (52.6% after 24 h of soaking) compared to the chit/HA (30.7%) and thus can serve as a very good drug delivery carrier. Chit/glu/HA scaffold was also more favourable to osteoblast survival (near 100% viability after 24-h culture), proliferation, and spreading compared to the chit/HA (63% viability). The chit/glu/HA possesses better biomedical potential than chit/HA scaffold. Nevertheless, poor mechanical properties of the chit/glu/HA limit its application to non-load bearing implantation area. - Highlights: • Chitosan/HA and chit/β-1,3-glucan/HA scaffolds for bone regeneration were compared. • Chit/HA significantly reduced osteoblast viability to 63% compared to chit/glu/HA. • Unlike chit/HA, chit/glu/HA favoured cell adhesion, spreading, and proliferation. • Chit/HA had better compressive strength and Young's modulus than chit/glu/HA. • Chit/glu/HA revealed significantly higher

  1. Alpha liquid scintillation counting: past, present, and future

    International Nuclear Information System (INIS)

    McDowell, W.J.

    1979-01-01

    Beta liquid scintillation counting has been used for about 30 years, and its effectiveness for alpha particles has been known for almost that long; however, the technique has not been widely applied to alpha particle detection because of poor energy resolution, high background, and variable interference from beta and gamma radiation. Beginning with the work of Horrocks in the early 1960s, improvements in energy resolution and background rejection have been made. Further developments at Oak Ridge National Laboratory over the past 10 to 12 years have resulted in improved methods of sample preparation (using liquid-liquid extraction methods to isolate the sample and introduce it into the scintillator) and better instrumentation, including electronic rejection of beta and gamma pulses. Energy resolutions of 200- to 300-keV FWHM and background counts of 0.01 cpm are now routine. Alpha liquid scintillation spectrometry is now suitable for a wide range of applications, from the accurate quantitative determination of relatively large amounts of known nuclides in laboratory-generated samples to the detection and identification of very small, subpicocurie amounts of alpha emitters in environmental-type samples. Suitable nuclide separation procedures, sample preparation methods, and instrument configurations are outlined for a variety of analyses

  2. Validation the quantification of beta emitters activity in urine by scintillation spectrometry in the liquid phase; Validacion de la cuantificacion de actividad de emisores beta en orina mediante espectrometria de centelleo en fase liquida

    Energy Technology Data Exchange (ETDEWEB)

    Sierra, I.; Hernandez, C.; Benito, P.; Lopez, C.

    2013-07-01

    In this paper the methodology used in the validation of the technique for quantifying activity of some beta emitters in urine ({sup 3}H, {sup 1}4C, {sup 3}5S, {sup 3}2P and {sup 9}0Sr) by scintillation spectrometry Liquid Phase (Liquid Scintillation Counting, LSC) is described in bio elimination Laboratory Service CIEMAT Radiation Dosimetry accredited since last year for carrying out assays measure radiation dose based on ISO forth above. (Author)

  3. Calculation of the detection efficiency in liquid scintillators. II. Single positron emitters; Calculo de la eficiencia de deteccion en liquidos centelleadores. II Nucleidos que se desintegran por emision simple de positrones

    Energy Technology Data Exchange (ETDEWEB)

    Grau Malonda, A.; Garcia Torano, E.

    1982-07-01

    Counting efficiency as a function of the figure of merit for 30 positron emitters has been computed from the positron energy spectrum. Only the efficiency contribution of positrons has been taken into consideration. The contribution of the annihilation photons depending on the volume of the scintillator will be investigated in a near future. Efficiency vs figure of merit is plotted and tabulated. (Author) 19 refs.

  4. Depth determination of low-energy photon emitter deposits in tissue by means of high-resolution X-ray spectrometry

    International Nuclear Information System (INIS)

    Schlueter, W.

    1982-01-01

    A method has been developed for ascertaining the depth of low-energy photon emitters deposited in wounds. It is based on the determination of the energy-dependent absorption of the emitted photons by the tissue separating source and detector. The method is applicable to counting for low-energy photon-emitting nuclides that can be characterized by more than one quantum energy. Attenuation coefficients were given for lard, beef, and five tissue- equivalent materials. For spectrometry, a planar Ge(Li) detector proved most suitable. (author)

  5. Hanford whole body counting manual

    International Nuclear Information System (INIS)

    Palmer, H.E.; Rieksts, G.A.; Lynch, T.P.

    1990-06-01

    This document describes the Hanford Whole Body Counting Program as it is administered by Pacific Northwest Laboratory (PNL) in support of the US Department of Energy--Richland Operations Office (DOE-RL) and its Hanford contractors. Program services include providing in vivo measurements of internally deposited radioactivity in Hanford employees (or visitors). Specific chapters of this manual deal with the following subjects: program operational charter, authority, administration, and practices, including interpreting applicable DOE Orders, regulations, and guidance into criteria for in vivo measurement frequency, etc., for the plant-wide whole body counting services; state-of-the-art facilities and equipment used to provide the best in vivo measurement results possible for the approximately 11,000 measurements made annually; procedures for performing the various in vivo measurements at the Whole Body Counter (WBC) and related facilities including whole body counts; operation and maintenance of counting equipment, quality assurance provisions of the program, WBC data processing functions, statistical aspects of in vivo measurements, and whole body counting records and associated guidance documents. 16 refs., 48 figs., 22 tabs

  6. The influence of the calibration standard and the chemical composition of the water samples residue in the counting efficiency of proportional detectors for gross alpha and beta counting. Application on the radiologic control of the IPEN-CNEN/SP

    International Nuclear Information System (INIS)

    Santos, Cecilia Martins

    2003-01-01

    In this work the efficiency calibration curves of thin-window and low background gas-flow proportional counters were determined for calibration standards with different energies and different absorber thicknesses. For the gross alpha counting we have used 241 Am and natural uranium standards and for the gross beta counting we have used 90 Sr/ 90 Y and 137 Cs standards in residue thicknesses ranging from 0 to approximately 18 mg/cm 2 . These sample thicknesses were increased with a previously determined salted solution prepared simulating the chemical composition of the underground water of IPEN The counting efficiency for alpha emitters ranged from 0,273 +- 0,038 for a weightless residue to only 0,015 +- 0,002 in a planchet containing 15 mg/cm 2 of residue for 241 Am standard. For natural uranium standard the efficiency ranged from 0,322 +- 0,030 for a weightless residue to 0,023 +- 0,003 in a planchet containing 14,5 mg/cm 2 of residue. The counting efficiency for beta emitters ranged from 0,430 +- 0,036 for a weightless residue to 0,247 +- 0,020 in a planchet containing 17 mg/cm 2 of residue for 137 Cs standard. For 90 Sr/ 90 Y standard the efficiency ranged from 0,489 +- 0,041 for a weightless residue to 0,323 +- 0,026 in a planchet containing 18 mg/cm 2 of residue. Results make evident the counting efficiency variation with the alpha or beta emitters energies and the thickness of the water samples residue. So, the calibration standard, the thickness and the chemical composition of the residue must always be considered in the gross alpha and beta radioactivity determination in water samples. (author)

  7. Bør leger ha reservasjonsrett ved assistert befruktning?

    Directory of Open Access Journals (Sweden)

    Morten Magelssen

    2011-10-01

    Full Text Available Omfanget av helsepersonells reservasjonsrett har nylig vært gjenstand for debatt i Norge. Vi spør om leger bør ha reservasjonsrett ved utførelse og henvisning til assistert befruktning, og drøfter argumenter for og imot ved hjelp av et rammeverk med sju kriterier for vurdering av reservasjon. Reservasjonsrettens grunnleggende dilemma er hvordan to viktige hensyn, henholdsvis pasientens rett til behandling og hensynet til helsepersonellets moralske integritet, best kan ivaretas. Det argumenteres for at leger bør ha rett til å reservere seg mot å utføre, assistere ved og henvise til assistert befruktning generelt hvis begrunnelsen er hensynet til befruktede eggs moralske verdi. Videre finner vi at leger også kan ha en moralsk rett til reservasjon mot å utføre, assistere ved og henvise til assistert befruktning for likekjønnede, men da på nærmere spesifiserte vilkår.Nøkkelord: reservasjonsrett, assistert befruktning, samvittighet, moralsk integritetEnglish summary: Should physicians have the right to conscientiously object to assisted reproduction?The extent of the healthcare worker's right to conscientious objection has recently been debated in Norway. This article asks whether physicians should have a right to conscientious objection to the performance of, and referral for, assisted reproduction, and discusses arguments for and against the same, utilizing a framework of seven criteria for the evaluation of conscientious objection. The fundamental dilemma of conscientious objection is how two important considerations can be reconciled: the patient's right to treatment, and the protection of the healthcare worker's moral integrity. It is argued that physicians should have the right to object to performing, assisting with, and referring for assisted reproduction generally when the objection is grounded in the moral value of the embryo. Furthermore, physicians may also have a moral right to object to performing, assisting with, and

  8. Determination of phosphorus in biological samples by thermal neutron activation followed by β--counting

    International Nuclear Information System (INIS)

    Weginwar, R.G.; Samudralwar, D.L.; Garg, A.N.

    1989-01-01

    Phosphorus was determined using the β - emitter 32 P by instrumental neutron activation analysis (INAA) in several NBS and IAEA standards, and in samples of biological origin such as human and animal blood, cancerous tissue, edible plant leaves, diets, milk samples, etc. The method involves thermal neutron irradiation (for 2-10 h in a reactor) followed by β - counting on an end-window gas flow proportional counter using aluminium filter. The results are within ±10% of the certified values in most cases. (author) 29 refs.; 3 tabs

  9. Scale-dependent associations of Band-tailed Pigeon counts at mineral sites

    Science.gov (United States)

    Overton, Cory T.; Casazza, Michael L.; Coates, Peter S.

    2010-01-01

    The abundance of Band-tailed Pigeons (Patagioenas fasciata monilis) has declined substantially from historic numbers along the Pacific Coast. Identification of patterns and causative factors of this decline are hampered because habitat use data are limited, and temporal and spatial variability patterns associated with population indices are not known. Furthermore, counts are influenced not only by pigeon abundance but also by rate of visitation to mineral sites, which may not be consistent. To address these issues, we conducted mineral site counts during 2001 and 2002 at 20 locations from 4 regions in the Pacific Northwest, including central Oregon and western Washington, USA, and British Columbia, Canada. We developed inference models that consisted of environmental factors and spatial characteristics at multiple spatial scales. Based on information theory, we compared models within a final set that included variables measured at 3 spatial scales (0.03 ha, 3.14 ha, and 7850 ha). Pigeon counts increased from central Oregon through northern Oregon and decreased into British Columbia. After accounting for this spatial pattern, we found that pigeon counts increased 12% ± 2.7 with a 10% increase in the amount of deciduous forested area within 100 m from a mineral site. Also, distance from the mineral site of interest to the nearest known mineral site was positively related to pigeon counts. These findings provide direction for future research focusing on understanding the relationships between indices of relative abundance and complete counts (censuses) of pigeon populations by identifying habitat characteristics that might influence visitation rates. Furthermore, our results suggest that spatial arrangement of mineral sites influences Band-tailed Pigeon counts and the populations which those counts represent.

  10. The influence of lime and nitrogen fertilisers on spore counts of Pithomyces chartarum in pasture.

    Science.gov (United States)

    Cuttance, E L; Laven, R A; Mason, W A; Stevenson, M

    2016-11-01

    To determine whether the application of lime or nitrogen to pasture affected the spore counts of Pithomyces chartarum. The lime application studies were undertaken on a spring-calving, pasture-based, commercial dairy farm near Te Awamutu, New Zealand. On 6 November 2012, five randomly selected paddocks were split into three equal sections. In two of the sections, lime was applied at either 1.5 or 2.5 t/ha, and the central section was left as an untreated control. Each section was sampled for spore counting weekly from 16 January to 15 May 2013. Starting in January 2013, five other randomly selected paddocks were monitored for spore counts. On 20 March 2013 the average spore counts in three paddocks were >100,000 spores/g of pasture. These paddocks were then divided into three equal sections and lime was applied as described above. Spore counting in each section continued weekly until 15 May 2013. The nitrogen application study was carried out on three commercial dairy farms near Te Awamutu, New Zealand. Two randomly selected paddocks on each farm were divided into three equal sections and, on 20 December 2012, nitrogen in the form of urea was applied at either 50 or 80 kg urea/ha to two of the sections; the central section remained as an untreated control. Each section was sampled for spore counting weekly from 16 January to 15 May 2013. Following pre-summer lime application, treatment at 1.5 or 2.5 t/ha did not affect spore counts over time compared with the control section (p>0.26). Similarly following autumn lime application, treatment at 1.5 or 2.5 t/ha did not affect spore counts over time compared with the control section (p>0.11). Following nitrogen application median spore counts remained 0.49). This study found that application of lime before the risk period for facial eczema, in November, application of lime after a spore count rise, in March, or urea application in December did not affect changes in number of spores produced by P. chartarum. This

  11. Immunomodulatory Effects of Hemagglutinin- (HA- Modified A20 B-Cell Lymphoma Expanded as a Brain Tumor on Adoptively Transferred HA-Specific CD4+ T Cells

    Directory of Open Access Journals (Sweden)

    Valentin P. Shichkin

    2014-01-01

    Full Text Available Previously, the mouse A20 B-cell lymphoma engineered to express hemagglutinin (HA antigen (A20HA was used as a systemic tumor model. In this work, we used the A20HA cells as a brain tumor. HA-specific CD4+ T cells were transferred intravenously in a tail vein 5 days after A20HA intracranial inoculation and analyzed on days 2, 9, and 16 after the adoptive transfer by different methods. The transferred cells demonstrated state of activation as early as day 2 after the adoptive transfer and most the of viable HA-specific cells became anergic on day 16. Additionally, symptoms of systemic immunosuppression were observed in mice with massive brain tumors at a late stage of the brain tumor progression (days 20–24 after the A20HA inoculation. Despite that, a deal of HA-specific CD4+ T cells kept the functional activity even at the late stage of A20HA tumor growth. The activated HA-specific CD4+ T cells were found also in the brain of brain-tumor-bearing mice. These cells were still responding to reactivation with HA-peptide in vitro. Our data support an idea about sufficient role of both the tumor-specific and -nonspecific mechanisms inducing immunosuppression in cancer patients.

  12. Temporal trends in sperm count

    DEFF Research Database (Denmark)

    Levine, Hagai; Jørgensen, Niels; Martino-Andrade, Anderson

    2017-01-01

    a predefined protocol 7518 abstracts were screened and 2510 full articles reporting primary data on SC were reviewed. A total of 244 estimates of SC and TSC from 185 studies of 42 935 men who provided semen samples in 1973-2011 were extracted for meta-regression analysis, as well as information on years.......006, respectively). WIDER IMPLICATIONS: This comprehensive meta-regression analysis reports a significant decline in sperm counts (as measured by SC and TSC) between 1973 and 2011, driven by a 50-60% decline among men unselected by fertility from North America, Europe, Australia and New Zealand. Because......BACKGROUND: Reported declines in sperm counts remain controversial today and recent trends are unknown. A definitive meta-analysis is critical given the predictive value of sperm count for fertility, morbidity and mortality. OBJECTIVE AND RATIONALE: To provide a systematic review and meta-regression...

  13. Avoimen lähdekoodin HA-tietokannat

    OpenAIRE

    Vartio, Sami

    2014-01-01

    Insinöörityössä perehdyttiin avoimen lähdekoodin periaatteisiin ja lisenssimalleihin sekä huomioitiin liiketaloudelliset lähtökohdat. Tavoitteena oli tutustua järjestelmän saatavuuteen sekä klusteroinnin periaatteisiin. Järjestelmän saatavuus (HA) on tietojärjestelmien suunnittelussa käytettävä käytäntö, joka pyrkii siihen että järjestelmä on aina käyttäjän käytettävissä. Aluksi käsiteltiin perustietoja sekä teoriaa. Tutkimuksen edetessä paneuduttiin laajemmin yleisimpiin avoimen lähdeko...

  14. Haïti-Quisqueya: une double insularité

    Directory of Open Access Journals (Sweden)

    Jean-Marie THÉODAT

    1998-09-01

    Full Text Available Deux pays se partagent une île coupée par une frontière méridienne de plus de 300 km: Haïti à l'ouest, Quisqueya à l'est. Cette coupure est l'héritage du partage colonial de l'île entre la France et l'Espagne, et le résultat de la dynamique spatiale contrastée des deux nations qui y sont nées et qui ont eu recours à des principes d'encadrement distincts.De là un sentiment de double insularité, chaque pays se comportant vis-à-vis de son voisin comme s'ils étaient situés sur deux îles séparées.

  15. Photon-counting image sensors

    CERN Document Server

    Teranishi, Nobukazu; Theuwissen, Albert; Stoppa, David; Charbon, Edoardo

    2017-01-01

    The field of photon-counting image sensors is advancing rapidly with the development of various solid-state image sensor technologies including single photon avalanche detectors (SPADs) and deep-sub-electron read noise CMOS image sensor pixels. This foundational platform technology will enable opportunities for new imaging modalities and instrumentation for science and industry, as well as new consumer applications. Papers discussing various photon-counting image sensor technologies and selected new applications are presented in this all-invited Special Issue.

  16. miR-198 Represses the Proliferation of HaCaT Cells by Targeting Cyclin D2

    Directory of Open Access Journals (Sweden)

    Jian Wang

    2015-07-01

    Full Text Available Background: MiR-198 has been considered as an inhibitor of cell proliferation, invasion, migration and a promoter of apoptosis in most cancer cells, while its effect on non-cancer cells is poorly understood. Methods: The effect of miR-198 transfection on HaCaT cell proliferation was firstly detected using Cell Count Kit-8 and the cell cycle progression was analyzed by flow cytometry. Using bioinformatics analyses and luciferase assay, a new target of miR-198 was searched and identified. Then, the effect of the new target gene of miR-198 on cell proliferation and cell cycle was also detected. Results: Here we showed that miR-198 directly bound to the 3′-UTR of CCND2 mRNA, which was a key regulator in cell cycle progression. Overexpressed miR-198 repressed CCND2 expression at mRNA and protein levels and subsequently led to cell proliferation inhibition and cell cycle arrest in the G1 phase. Transfection ofSiCCND2 in HaCaT cells showed similar inhibitory effects on cell proliferation and cell cycle progression. Conclusion: In conclusion, we have identified that miR-198 inhibited HaCaT cell proliferation by directly targeting CCND2.

  17. Emittance growth caused by bends in the Los Alamos free-electron laser energy recovery experiment

    International Nuclear Information System (INIS)

    Carlsten, B.E.

    1987-01-01

    Experimentally transporting the beam from the wiggler to the decelerators in the energy recovery experiment (ERX) at the Los Alamos National Laboratory free-electron laser was more difficult than expected because of the large initial emittance in the beam. This emittance was apparently caused in an early 60 0 achromatic bend. To get this beam through subsequent bends without wall interception, the quadrupole focusing had to be changed from the design amount; as a result, the emittance grew further. This paper discusses various mechanisms for this emittance growth in the 60 0 bend, including effects caused by path changes in the bend resulting from wake-field-induced energy changes of particles in the beam and examines emittance filters, ranging from a simple aperture near a beam crossover to more complicated telescope schemes designed to regain the original emittance before the 60 0 bend

  18. Radial arrays of nano-electrospray ionization emitters and methods of forming electrosprays

    Science.gov (United States)

    Kelly, Ryan T [West Richland, WA; Tang, Keqi [Richland, WA; Smith, Richard D [Richland, WA

    2010-10-19

    Electrospray ionization emitter arrays, as well as methods for forming electrosprays, are described. The arrays are characterized by a radial configuration of three or more nano-electrospray ionization emitters without an extractor electrode. The methods are characterized by distributing fluid flow of the liquid sample among three or more nano-electrospray ionization emitters, forming an electrospray at outlets of the emitters without utilizing an extractor electrode, and directing the electrosprays into an entrance to a mass spectrometry device. Each of the nano-electrospray ionization emitters can have a discrete channel for fluid flow. The nano-electrospray ionization emitters are circularly arranged such that each is shielded substantially equally from an electrospray-inducing electric field.

  19. An integrated microcombustor and photonic crystal emitter for thermophotovoltaics

    Science.gov (United States)

    Chan, Walker R.; Stelmakh, Veronika; Allmon, William R.; Waits, Christopher M.; Soljacic, Marin; Joannopoulos, John D.; Celanovic, Ivan

    2016-11-01

    Thermophotovoltaic (TPV) energy conversion is appealing for portable millimeter- scale generators because of its simplicity, but it relies on a high temperatures. The performance and reliability of the high-temperature components, a microcombustor and a photonic crystal emitter, has proven challenging because they are subjected to 1000-1200°C and stresses arising from thermal expansion mismatches. In this paper, we adopt the industrial process of diffusion brazing to fabricate an integrated microcombustor and photonic crystal by bonding stacked metal layers. Diffusion brazing is simpler and faster than previous approaches of silicon MEMS and welded metal, and the end result is more robust.

  20. An integrated microcombustor and photonic crystal emitter for thermophotovoltaics

    International Nuclear Information System (INIS)

    Chan, Walker R.; Stelmakh, Veronika; Joannopoulos, John D.; Celanovic, Ivan; Allmon, William R.; Waits, Christopher M.; Soljacic, Marin

    2016-01-01

    Thermophotovoltaic (TPV) energy conversion is appealing for portable millimeter- scale generators because of its simplicity, but it relies on a high temperatures. The performance and reliability of the high-temperature components, a microcombustor and a photonic crystal emitter, has proven challenging because they are subjected to 1000-1200°C and stresses arising from thermal expansion mismatches. In this paper, we adopt the industrial process of diffusion brazing to fabricate an integrated microcombustor and photonic crystal by bonding stacked metal layers. Diffusion brazing is simpler and faster than previous approaches of silicon MEMS and welded metal, and the end result is more robust. (paper)

  1. Revisiting the level scheme of the proton emitter 151Lu

    International Nuclear Information System (INIS)

    Wang, F.; Sun, B.H.; Liu, Z.; Scholey, C.; Eeckhaudt, S.; Grahn, T.; Greenlees, P.T.; Jones, P.; Julin, R.; Juutinen, S.; Kettelhut, S.; Leino, M.; Nyman, M.; Rahkila, P.; Saren, J.; Sorri, J.; Uusitalo, J.; Ashley, S.F.; Cullen, I.J.; Garnsworthy, A.B.; Gelletly, W.; Jones, G.A.; Pietri, S.; Podolyak, Z.; Steer, S.; Thompson, N.J.; Walker, P.M.; Williams, S.; Bianco, L.; Darby, I.G.; Joss, D.T.; Page, R.D.; Pakarinen, J.; Rigby, S.; Cullen, D.M.; Khan, S.; Kishada, A.; Gomez-Hornillos, M.B.; Simpson, J.; Jenkins, D.G.; Niikura, M.; Seweryniak, D.; Shizuma, Toshiyuki

    2015-01-01

    An experiment aiming to search for new isomers in the region of proton emitter 151 Lu was performed at the Accelerator Laboratory of the University of Jyväskylä (JYFL), by combining the high resolution γ-ray array JUROGAM, gas-filled RITU separator and GREAT detectors with the triggerless total data readout acquisition (TDR) system. In this proceeding, we revisit the level scheme of 151 Lu by using the proton-tagging technique. A level scheme consistent with the latest experimental results is obtained, and 3 additional levels are identified at high excitation energies. (author)

  2. Bent solenoids for spectrometers and emittance exchange sections

    International Nuclear Information System (INIS)

    Norem, J.

    1999-01-01

    Bent solenoids can be used to transport low energy beams as they provide both confinement and dispersion of particle orbits. Solenoids are being considered both as emittance exchange sections and spectrometers in the muon cooling system as part of the study of the muon collider. They present the results of a study of bent solenoids which considers the design of coupling sections between bent solenoids to straight solenoids, drift compensation fields, aberrations, and factors relating to the construction, such as field ripple, stored energy, coil forces and field errors

  3. A program to research emittance growth in bends

    International Nuclear Information System (INIS)

    Bohn, C.L.

    1996-01-01

    A research program to explore the phenomenon of emittance growth in bends due to noninertial space-charge effects has been defined and initiated. The program combines theoretical, numerical, and experimental investigations. This paper summarizes the motivation of the work and highlights CEBAF close-quote s need for immediate results. The program close-quote s key elements, some of which qualitatively differ from the standard approach used to investigate the production and effects of coherent synchrotron radiation in synchrotrons and storage rings, are enumerated and discussed. copyright 1996 American Institute of Physics

  4. The Brookhaven ATF low-emittance beam line

    International Nuclear Information System (INIS)

    Wang, X.J.; Kirk, H.G.

    1991-01-01

    One component of the experimental program at the Brookhaven Accelerator Test Facility (ATF) consists of a class of experiments which will study the acceleration of electrons through micron-size structures which are exposed in coincidence to a 100 GW CO 2 laser beam. These experiments require the development and control of an electron beam with geometric emittances on the order of 10 -10 m-rad and intensities on the order of 10 6 electrons. In this paper, the authors describe the strategies for producing such beams and the effects of higher-order aberrations. Particle tracking results are presented for the final-focus system

  5. The Brookhaven ATF low-emittance beam line

    International Nuclear Information System (INIS)

    Wang, X.J.

    1991-01-01

    One component of the experimental program at the Brookhaven Accelerator Test Facility (ATF) consists of a class of experiments which will study the acceleration of electrons through micron-size structures which are exposed in coincidence to a 100 GW CO 2 laser beam. These experiments require the development and control of an electron beam with geometric emittances on the order of 10 -10 m-rad and intensities on the order of 10 6 electrons. In this paper, we describe the strategies for producing such beams and the effects of high-order aberrations. Particle tracking results are presented for the final-focus system. 9 refs., 6 figs., 2 tabs

  6. Measurement of Alpha Emitters Concentration in Imported Cigarettes

    International Nuclear Information System (INIS)

    Nasser Allah, Z.K.; Musa, W.A.; AL-Rawi, A.A.S.

    2011-01-01

    The aime of this study was to measured the alpha emitters concentration of (15) different kinds of imported cigarettes. the nuclear reaction used U-235(n, f) obtained by the bombardment of U-235 with thermal neutrons from (Am B e)neutron source with thermal flux of(5*10 3 n.cm -2 .s -1 ). The Results obtained showed the values of the Uranium concentration, and varies from (0.041 ppm) in five stares kind to (2.374ppm) in Machbeth (chocolate) 100's kind. All the result obtained are within the limit levels as given by UNSCAR data

  7. Calculations of emittance and damping time effects in the SLC damping rings

    International Nuclear Information System (INIS)

    Limberg, T.; Moshammer, H.; Raubenheimer, T.; Spencer, J.; Siemann, R.

    1992-03-01

    In a recent NDR machine experiment the transverse emittance was studied as a function of store time and tune. To explain the observed transverse emittance damping time constants, the magnetic measurement data of the longitudinal field of the bending magnets had to be taken into account. The variation of the transverse emittances with tune due to misalignments and the associated anomalous dispersion is studied as well as the effect of synchrobetatron coupling due to dispersion in the RF cavities

  8. Crystal structure of the HA3 subcomponent of Clostridium botulinum type C progenitor toxin.

    Science.gov (United States)

    Nakamura, Toshio; Kotani, Mao; Tonozuka, Takashi; Ide, Azusa; Oguma, Keiji; Nishikawa, Atsushi

    2009-01-30

    The Clostridium botulinum type C 16S progenitor toxin contains a neurotoxin and several nontoxic components, designated nontoxic nonhemagglutinin (HA), HA1 (HA-33), HA2 (HA-17), HA3a (HA-22-23), and HA3b (HA-53). The HA3b subcomponent seems to play an important role cooperatively with HA1 in the internalization of the toxin by gastrointestinal epithelial cells via binding of these subcomponents to specific oligosaccharides. In this study, we investigated the sugar-binding specificity of the HA3b subcomponent using recombinant protein fused to glutathione S-transferase and determined the three-dimensional structure of the HA3a-HA3b complex based on X-ray crystallography. The crystal structure was determined at a resolution of 2.6 A. HA3b contains three domains, domains I to III, and the structure of domain I resembles HA3a. In crystal packing, three HA3a-HA3b molecules are assembled to form a three-leaved propeller-like structure. The three HA3b domain I and three HA3a alternate, forming a trimer of dimers. In a database search, no proteins with high structural homology to any of the domains (Z score >10) were found. Especially, HA3a and HA3b domain I, mainly composed of beta-sheets, reveal a unique fold. In binding assays, HA3b bound sialic acid with high affinity, but did not bind galactose, N-acetylgalactosamine, or N-acetylglucosamine. The electron density of liganded N-acetylneuraminic acid was determined by crystal soaking. In the sugar-complex structure, the N-acetylneuraminic acid-binding site was located in the cleft formed between domains II and III of HA3b. This report provides the first determination of the three-dimensional structure of the HA3a-HA3b complex and its sialic acid binding site. Our results will provide useful information for elucidating the mechanism of assembly of the C16S toxin and for understanding the interactions with oligosaccharides on epithelial cells and internalization of the botulinum toxin complex.

  9. Characterization, Corrosion Resistance, and Cell Response of High-Velocity Flame-Sprayed HA and HA/TiO2 Coatings on 316L SS

    Science.gov (United States)

    Singh, Tejinder Pal; Singh, Harpreet; Singh, Hazoor

    2012-09-01

    The main aim of this study is to evaluate corrosion and biocompatibility behavior of thermal spray hydroxyapatite (HA) and hydroxyapatite/titania bond (HA/TiO2)-coated 316L stainless steel (316L SS). In HA/TiO2 coatings, TiO2 was used as a bond coat between HA top coat and 316L SS substrate. The coatings were characterized by x-ray diffraction and scanning electron microscopy/energy dispersive spectroscopy, and corrosion resistance determined for the uncoated substrate and the two coatings. The biological behavior was investigated by the cell culture studies using osteosarcoma cell line KHOS-NP (R-970-5). The corrosion resistance of the steel was found to increase after the deposition of the HA and HA/TiO2 bond coatings. Both HA, as well as, HA/TiO2 coatings exhibit excellent bond strength of 49 and 47 MPa, respectively. The cell culture studies showed that HA-coated 316L SS specimens appeared more biocompatible than the uncoated and HA/TiO2-coated 316L SS specimens.

  10. Liquid scintillation, counting, and compositions

    International Nuclear Information System (INIS)

    Sena, E.A.; Tolbert, B.M.; Sutula, C.L.

    1975-01-01

    The emissions of radioactive isotopes in both aqueous and organic samples can be measured by liquid scintillation counting in micellar systems. The micellar systems are made up of scintillation solvent, scintillation solute and a mixture of surfactants, preferably at least one of which is relatively oil-soluble water-insoluble and another which is relatively water-soluble oil-insoluble

  11. Phase space quark counting rule

    International Nuclear Information System (INIS)

    Wei-gin, C.; Lo, S.

    1980-01-01

    A simple quark counting rule based on phase space consideration suggested before is used to fit all 39 recent experimental data points on inclusive reactions. Parameter free relations are found to agree with experiments. Excellent detail fits are obtained for 11 inclusive reactions

  12. Counting a Culture of Mealworms

    Science.gov (United States)

    Ashbrook, Peggy

    2007-01-01

    Math is not the only topic that will be discussed when young children are asked to care for and count "mealworms," a type of insect larvae (just as caterpillars are the babies of butterflies, these larvae are babies of beetles). The following activity can take place over two months as the beetles undergo metamorphosis from larvae to adults. As the…

  13. Counting problems for number rings

    NARCIS (Netherlands)

    Brakenhoff, Johannes Franciscus

    2009-01-01

    In this thesis we look at three counting problems connected to orders in number fields. First we study the probability that for a random polynomial f in Z[X] the ring Z[X]/f is the maximal order in Q[X]/f. Connected to this is the probability that a random polynomial has a squarefree

  14. On Counting the Rational Numbers

    Science.gov (United States)

    Almada, Carlos

    2010-01-01

    In this study, we show how to construct a function from the set N of natural numbers that explicitly counts the set Q[superscript +] of all positive rational numbers using a very intuitive approach. The function has the appeal of Cantor's function and it has the advantage that any high school student can understand the main idea at a glance…

  15. Logistic regression for dichotomized counts.

    Science.gov (United States)

    Preisser, John S; Das, Kalyan; Benecha, Habtamu; Stamm, John W

    2016-12-01

    Sometimes there is interest in a dichotomized outcome indicating whether a count variable is positive or zero. Under this scenario, the application of ordinary logistic regression may result in efficiency loss, which is quantifiable under an assumed model for the counts. In such situations, a shared-parameter hurdle model is investigated for more efficient estimation of regression parameters relating to overall effects of covariates on the dichotomous outcome, while handling count data with many zeroes. One model part provides a logistic regression containing marginal log odds ratio effects of primary interest, while an ancillary model part describes the mean count of a Poisson or negative binomial process in terms of nuisance regression parameters. Asymptotic efficiency of the logistic model parameter estimators of the two-part models is evaluated with respect to ordinary logistic regression. Simulations are used to assess the properties of the models with respect to power and Type I error, the latter investigated under both misspecified and correctly specified models. The methods are applied to data from a randomized clinical trial of three toothpaste formulations to prevent incident dental caries in a large population of Scottish schoolchildren. © The Author(s) 2014.

  16. Vote Counting as Mathematical Proof

    DEFF Research Database (Denmark)

    Schürmann, Carsten; Pattinson, Dirk

    2015-01-01

    then consists of a sequence (or tree) of rule applications and provides an independently checkable certificate of the validity of the result. This reduces the need to trust, or otherwise verify, the correctness of the vote counting software once the certificate has been validated. Using a rule...

  17. Counting SET-free sets

    OpenAIRE

    Harman, Nate

    2016-01-01

    We consider the following counting problem related to the card game SET: How many $k$-element SET-free sets are there in an $n$-dimensional SET deck? Through a series of algebraic reformulations and reinterpretations, we show the answer to this question satisfies two polynomiality conditions.

  18. Repeatability of differential goat bulk milk culture and associations with somatic cell count, total bacterial count, and standard plate count

    OpenAIRE

    Koop, G.; Dik, N.; Nielen, M.; Lipman, L.J.A.

    2010-01-01

    The aims of this study were to assess how different bacterial groups in bulk milk are related to bulk milk somatic cell count (SCC), bulk milk total bacterial count (TBC), and bulk milk standard plate count (SPC) and to measure the repeatability of bulk milk culturing. On 53 Dutch dairy goat farms, 3 bulk milk samples were collected at intervals of 2 wk. The samples were cultured for SPC, coliform count, and staphylococcal count and for the presence of Staphylococcus aureus. Furthermore, SCC ...

  19. Emittance and trajectory control in the main linacs of the NLC

    International Nuclear Information System (INIS)

    Assmann, R.; Adolphsen, C.; Bane, K.; Raubenheimer, T.O.; Thompson, K.

    1996-09-01

    The main linacs of the next generation of linear colliders need to accelerate the particle beams to energies of up to 750 GeV while maintaining very small emittances. This paper describes the main mechanisms of static emittance growth in the main linacs of the Next Linear Collider (NLC). The authors present detailed simulations of the trajectory and emittance control algorithms that are foreseen for the NLC. They show that the emittance growth in the main linacs can be corrected down to about 110%. That number is significantly better than required for the NLC design luminosity

  20. Experimental studies on coherent synchrotron radiation at an emittance exchange beam line

    Directory of Open Access Journals (Sweden)

    J. C. T. Thangaraj

    2012-11-01

    Full Text Available One of the goals of the Fermilab A0 photoinjector is to investigate experimentally the transverse to longitudinal emittance exchange (EEX principle. Coherent synchrotron radiation in the emittance exchange line could limit the performance of the emittance exchanger at short bunch lengths. In this paper, we present experimental and simulation studies of the coherent synchrotron radiation (CSR in the emittance exchange line at the A0 photoinjector. We report on time-resolved CSR studies using a skew-quadrupole technique. We also demonstrate the advantages of running the EEX with an energy-chirped beam.

  1. Multibunch emittance growth and its corrections in S-Band linear collider

    International Nuclear Information System (INIS)

    Gao, J.

    1994-11-01

    Multibunch emittance growths caused by long range wake fields with the misalignments of accelerating structures and quadrupoles in S-Band linear collider are studied. Tolerances for the misalignment errors of accelerating structures and quadrupoles are given corresponding to different detuned+damped structures. At the end of main linac, emittance corrector (EC) is proposed to be used to reduce further the multibunch emittance. Numerical simulations show that the effect of EC is obvious (multibunch emittance can be reduced about one order of magnitude), and it is believed that this kind of EC will be necessary for future linear colliders. (author). 16 refs., 21 figs., 4 tabs

  2. Emittance growth due to noise and its suppression with the Feedback system in large hadron colliders

    International Nuclear Information System (INIS)

    Lebedev, V.; Parkhomchuk, V.; Shiltsev, V.; Stupakov, G.

    1993-03-01

    The problem of emittance growth due to random fluctuation of the magnetic field in hadron colliders is considered. Based on a simple one-dimensional linear model, a formula for an emittance growth rate as a function of the noise spectrum is derived. Different sources of the noise are analyzed and their role is estimated for the Superconducting Super Collider (SSC). A theory of feedback suppression of the emittance growth is developed which predicts the residual growth of the emittance in the accelerator with a feedback system

  3. Improvements in emittance wake field optimization for the SLAC Linear Collider

    CERN Document Server

    Decker, Franz Josef

    2003-01-01

    The transverse emittances in the SLAC Linear Collider can be severely diluted by collective wakefield effects and dispersion. For the 1997/98 SLC/SLD run important changes were implemented in the way the emittance is optimized. Early in the linac, where the energy spread is large due to BNS damping, the emittance growth is dominated by dispersion. In this regime emittance tuning bumps may introduce additional wakefield tails and their use is now avoided. At the end of the linac the energy spread is minimal and the emittance measurement is most sensitive to wakefield emittance dilution. In previous years, the emittances were tuned on wire scanners located near but not at the end of the linac (after about 90% of its length). Simulations show that emittance growth of up to 100% can occur in the remaining 10%. In this run wire scanners at the entrance of the Final Focus, the last place where the emittances can be measured, were used for the optimization. Screens at the end of the linac allow additional real time ...

  4. Strong nonlinearity-induced correlations for counterpropagating photons scattering on a two-level emitter

    DEFF Research Database (Denmark)

    Nysteen, Anders; McCutcheon, Dara; Mørk, Jesper

    2015-01-01

    We analytically treat the scattering of two counterpropagating photons on a two-level emitter embedded in an optical waveguide. We find that the nonlinearity of the emitter can give rise to significant pulse-dependent directional correlations in the scattered photonic state, which could be quanti......We analytically treat the scattering of two counterpropagating photons on a two-level emitter embedded in an optical waveguide. We find that the nonlinearity of the emitter can give rise to significant pulse-dependent directional correlations in the scattered photonic state, which could...

  5. Very low recombination phosphorus emitters for high efficiency crystalline silicon solar cells

    International Nuclear Information System (INIS)

    Ortega, P; Vetter, M; Bermejo, S; Alcubilla, R

    2008-01-01

    This work studies low recombination phosphorus emitters on c-Si. The emitters are fabricated by diffusion from solid sources and then passivated by thermal oxide yielding sheet resistances between 15 and 280 Ω/sq. Emitter saturation current densities lie in the 2.5–110 fA cm −2 range, leading to implicit open-circuit voltages between 674 and 725 mV. Bulk lifetime is limited by intrinsic recombination mechanisms. Surface recombination velocities between 80 and 300 cm s −1 have been obtained, appearing among the lowest reported in this range of emitter sheet resistances

  6. Analysis of emittance compensation and simulation results to photo-cathode RF gun

    CERN Document Server

    LiuShengGuang

    2002-01-01

    The emittance compensation technology will be used on the photo-cathode RF gun for Shanghai SDUV-FEL. The space charge force and its effect on electron beam transverse emittance in RF gun is studied, the principle of emittance compensation in phase-space is discussed. The authors have designed a compensation solenoid and calculated its magnetic field distribution. Its performance has been studied by the code PARMELA. A simulation result indicates that the normalized transverse RMS emittance for electron beam of 1.5 nC is 1.612 pi mm centre dot mrad, electron energy E = 5.71 MeV

  7. Experimental studies on coherent synchrotron radiation at an emittance exchange beam line

    Science.gov (United States)

    Thangaraj, J. C. T.; Thurman-Keup, R.; Ruan, J.; Johnson, A. S.; Lumpkin, A. H.; Santucci, J.

    2012-11-01

    One of the goals of the Fermilab A0 photoinjector is to investigate experimentally the transverse to longitudinal emittance exchange (EEX) principle. Coherent synchrotron radiation in the emittance exchange line could limit the performance of the emittance exchanger at short bunch lengths. In this paper, we present experimental and simulation studies of the coherent synchrotron radiation (CSR) in the emittance exchange line at the A0 photoinjector. We report on time-resolved CSR studies using a skew-quadrupole technique. We also demonstrate the advantages of running the EEX with an energy-chirped beam.

  8. Field emission characteristics of a small number of carbon fiber emitters

    Directory of Open Access Journals (Sweden)

    Wilkin W. Tang

    2016-09-01

    Full Text Available This paper reports an experiment that studies the emission characteristics of small number of field emitters. The experiment consists of nine carbon fibers in a square configuration. Experimental results show that the emission characteristics depend strongly on the separation between each emitter, providing evidence of the electric field screening effects. Our results indicate that as the separation between the emitters decreases, the emission current for a given voltage also decreases. The authors compare the experimental results to four carbon fiber emitters in a linear and square configurations as well as to two carbon fiber emitters in a paired array. Voltage-current traces show that the turn-on voltage is always larger for the nine carbon fiber emitters as compared to the two and four emitters in linear configurations, and approximately identical to the four emitters in a square configuration. The observations and analysis reported here, based on Fowler-Nordheim field emission theory, suggest the electric field screening effect depends critically on the number of emitters, the separation between them, and their overall geometric configuration.

  9. Intelligent Variable Emittance Panels Using New, ""True"" Solid Electrolyte, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This work further developed a highly promising Variable Emittance technology for spacecraft thermal control based on Conducting Polymer (CP) electrochromics...

  10. Use of sum-peak and coincidence counting methods for activity standardization of {sup 22}Na

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, E.M. de, E-mail: estela@ird.gov.br [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI/IRD/CNEN), Av. Salvador Allende, s/n, Recreio, CEP 22780-160 Rio de Janeiro (Brazil); Iwahara, A.; Poledna, R. [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI/IRD/CNEN), Av. Salvador Allende, s/n, Recreio, CEP 22780-160 Rio de Janeiro (Brazil); Silva, M.A.L. da [Coordenacao Geral de Instalacoes Nucleares/Comissao Nacional de Energia Nuclear, R. Gal. Severiano, 90 - Botafogo, CEP 22290-901 Rio de Janeiro (Brazil); Tauhata, L. [Fundacao Carlos Chagas Filho de Amparo a Pesquisa do Estado do Rio de Janeiro (FAPERJ), Av. Erasmo Braga, 118-6 Degree-Sign andar, CEP 20020-000 Centro, Rio de Janeiro (Brazil); Delgado, J.U. [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI/IRD/CNEN), Av. Salvador Allende, s/n, Recreio, CEP 22780-160 Rio de Janeiro (Brazil); Lopes, R.T. [Laboratorio de Instrumentacao Nuclear (LIN/PEN/COPPE/UFRJ), Caixa Postal 68509, CEP 21945-970 Rio de Janeiro (Brazil)

    2012-09-21

    A solution containing the positron emitter {sup 22}Na has been absolutely standardized using the 4{pi}{beta}-{gamma} coincidence counting method and the sum-peak spectrometry counting method. In the 4{pi}{beta}-{gamma} coincidence method two ways for the activity concentration measurements were used: gating on the 1275 keV photopeak and on the 1786 keV sum-peak where the knowledge of the {beta}{sup +}-branching ratio is required. In the sum-peak method the measurements were carried out using three experimental arrangements: the first composed by a well type 5 in. Multiplication-Sign 5 in. NaI(Tl) scintillation crystal, the second by a 3 in. Multiplication-Sign 3 in. NaI(Tl) scintillation crystal placed on the top of the first, resulting in a 4{pi} counting geometry and the third arrangement is a high purity coaxial germanium detector. The results that are obtained by these two methods are compatible within the standard uncertainty values with a coverage factor of k=2 ({approx}95% of the confidence level). This means that the sum-peak counting with its more simple experimental setup than the complex coincidence 4{pi}{beta}-{gamma} counting system gives consistent results for the activity standardization of {sup 22}Na with smaller uncertainties. Besides, the time period involved to attain the result of the standardization was quite shorter than the coincidence measurements used in this work.

  11. Problems in radiological protection involving alpha emitters in bone

    International Nuclear Information System (INIS)

    Dolphin, G.W.

    1976-01-01

    Quantitative dose/effect relationships for humans exposed to α emitters can only be established from data on humans exposed to this type of radiation. The risk of bone sarcoma from exposure to plutonium-239 may be established from the data on the human cases exposed to radium-226 either by consideration of the radiation dose to the osteoprogenitor cells or by use of the average bone dose together with a modifying factor to take into account the greater toxicity of plutonium relative to radium. The relative toxicity can be evaluated from the data on osteosarcoma incidence in animals. Both methods of risk estimation are given and criticised in the paper. In future recommendations, ICRP will not use the critical organ concept and the late effects from α emitters deposited in organs other than the bone will have to be taken into account in setting maximum permissible annual intakes. The implications of this and other proposed changes in ICRP concepts are discussed. (orig.) [de

  12. Field Emitter Arrays for a Free Electron Laser Application

    CERN Document Server

    Shing-Bruce-Li, Kevin; Ganter, Romain; Gobrecht, Jens; Raguin, Jean Yves; Rivkin, Leonid; Wrulich, Albin F

    2004-01-01

    The development of a new electron gun with the lowest possible emittance would help reducing the total length and cost of a free electron laser. Field emitter arrays (FEAs) are an attractive technology for electron sources of ultra high brightness. Indeed, several thousands of microscopic tips can be deposited on a 1 mm diameter area. Electrons are then extracted by applying voltage to a first grid layer close to the tip apexes, the so called gate layer, and focused by a second grid layer one micrometer above the tips. The typical aperture diameter of the gate and the focusing layer is in the range of one micrometer. One challenge for such cathodes is to produce peak currents in the ampere range since the usual applications of FEAs require less than milliampere. Encouraging peak current performances have been obtained by applying voltage pulses at low frequency between gate and tips. In this paper we report on different tip materials available on the market: diamond FEAs from Extreme Devices Inc., ZrC single ...

  13. Emittance scanner for intense low-energy ion beams

    International Nuclear Information System (INIS)

    Allison, P.W.; Sherman, J.D.; Holtkamp, D.B.

    1983-01-01

    An emittance scanner has been developed for use with low-energy H - ion beams to satisfy the following requirements: (1) angular resolution of +-1/2 mrad, (2) small errors from beam space charge, and (3) compact and simple design. The scanner consists of a 10-cm-long analyzer containing two slits and a pair of electric deflection plates driven by a +-500-V linear ramp generator. As the analyzer is mechanically driven across the beam, the front slit passes a thin ribbon of beam through the plates. The ion transit time is short compared with the ramp speed; therefore, the initial angle of the ions that pass through the rear slit is proportional to the instantaneous ramp voltage. The current through the rear slit then is proportional to the phase-space density d 2 i/dxdx'. The data are computer-analyzed to give, for example, rms emittance and phase-space density contours. Comparison of measured data with those calculated from a prepared (collimated) phase space is in good agreement

  14. Emittance measurement and modeling for the Fermilab Booster

    Directory of Open Access Journals (Sweden)

    Xiaobiao Huang

    2006-01-01

    Full Text Available Turn-by-turn beam profile data measured at the Fermilab Booster are studied. Lattice models with experimental accelerator ramping parameters are used to obtain the lattice functions for data analysis. We studied the horizontal and vertical emittance growth behavior in different stages of a booster ramping cycle and its relation to the beam intensity. The transverse and longitudinal components in the horizontal beam width are separated by a fitting model which makes use of the different scaling rules of the beam momentum. We analyze the post-transition horizontal beam size oscillation based on a model where the longitudinal phase-space mismatch has resulted from rf voltage mismatch during the transition-energy crossing. We carried out systematic multiparticle simulation to show that the source of the vertical emittance growth is a combination of the random errors in skew-quadrupole and dipole fields, and the systematic Montague resonance. The effect of random quadrupole field is small for the Fermilab Booster because the betatron envelope tunes are reasonably far away from the half-integer stop band.

  15. Longitudinal emittance blowup in the large hadron collider

    CERN Document Server

    Baudrenghien, P

    2013-01-01

    The Large Hadron Collider (LHC) relies on Landau damping for longitudinal stability. To avoid decreasing the stability margin at high energy, the longitudinal emittance must be continuously increased during the acceleration ramp. Longitudinal blowup provides the required emittance growth. The method was implemented through the summer of 2010. Band-limited RF phase-noise is injected in the main accelerating cavities during the whole ramp of about 11min. Synchrotron frequencies change along the energy ramp, but the digitally created noise tracks the frequency change. The position of the noise-band, relative to the nominal synchrotron frequency, and the bandwidth of the spectrum are set by pre-defined constants, making the diffusion stop at the edges of the demanded distribution. The noise amplitude is controlled by feedback using the measurement of the average bunch length. This algorithm reproducibly achieves the programmed bunch length of about 1.2ns, at flat top with low bunch-to-bunch scatter and provides a...

  16. Longitudinal emittance reduction in LEIR of ion beams for LHC

    CERN Document Server

    Angoletta, M E; Findlay, A; Hancock, S; Manglunki, D

    2014-01-01

    For the 2013 LHC ion run the anticipated request for batches from the PS Complex comprising four ion bunches spaced by 100 ns was changed to batches of two bunches spaced by 200 ns. This modified demand was met by suppressing a splitting step in the PS machine, but with the consequence of halving the longitudinal emittance required from LEIR. Thus NOMINAL Pb54+ beams from LEIR had to be delivered inside ~9 eVs to provide sufficient blow-up margin in the PS. Machine Development (MD) sessions were carried out in LEIR to investigate methods to satisfy these stricter requirements. Two main ingredients were found to reduce longitudinal emittance. The first and most important was to adjust carefully the frequency offset at capture in order to align the RF with the position where the beam is deposited by the electron cooling system prior to acceleration. The second ingredient was to reduce the final bucket area in order to reduce any residual filamentation during capture. This note documents the results obtaine...

  17. Infrared Organic Light-Emitting Diodes with Carbon Nanotube Emitters.

    Science.gov (United States)

    Graf, Arko; Murawski, Caroline; Zakharko, Yuriy; Zaumseil, Jana; Gather, Malte C

    2018-03-01

    While organic light-emitting diodes (OLEDs) covering all colors of the visible spectrum are widespread, suitable organic emitter materials in the near-infrared (nIR) beyond 800 nm are still lacking. Here, the first OLED based on single-walled carbon nanotubes (SWCNTs) as the emitter is demonstrated. By using a multilayer stacked architecture with matching charge blocking and charge-transport layers, narrow-band electroluminescence at wavelengths between 1000 and 1200 nm is achieved, with spectral features characteristic of excitonic and trionic emission of the employed (6,5) SWCNTs. Here, the OLED performance is investigated in detail and it is found that local conduction hot-spots lead to pronounced trion emission. Analysis of the emissive dipole orientation shows a strong horizontal alignment of the SWCNTs with an average inclination angle of 12.9° with respect to the plane, leading to an exceptionally high outcoupling efficiency of 49%. The SWCNT-based OLEDs represent a highly attractive platform for emission across the entire nIR. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Emittance Measurements from a Laser Driven Electron Injector

    CERN Document Server

    Reis, D

    2003-01-01

    The Gun Test Facility (GTF) at the Stanford Linear Accelerator Center was constructed to develop an appropriate electron beam suitable for driving a short wavelength free electron laser (FEL) such as the proposed Linac Coherent Light Source (LCLS). For operation at a wavelength of 1.5 (angstrom), the LCLS requires an electron injector that can produce an electron beam with approximately 1 pi mm-mrad normalized rms emittance with at least 1 nC of charge in a 10 ps or shorter bunch. The GTF consists of a photocathode rf gun, emittance-compensation solenoid, 3 m linear accelerator (linac), drive laser, and diagnostics to measure the beam. The rf gun is a symmetrized 1.6 cell, s-band high gradient, room temperature, photocathode structure. Simulations show that this gun when driven by a temporally and spatially shaped drive laser, appropriately focused with the solenoid, and further accelerated in linac can produce a beam that meets the LCLS requirements. This thesis describes the initial characterization of the ...

  19. Rayleigh scattering in an emitter-nanofiber-coupling system

    Science.gov (United States)

    Tang, Shui-Jing; Gao, Fei; Xu, Da; Li, Yan; Gong, Qihuang; Xiao, Yun-Feng

    2017-04-01

    Scattering is a general process in both fundamental and applied physics. In this paper, we investigate Rayleigh scattering of a solid-state-emitter coupled to a nanofiber, by S -matrix-like theory in k -space description. Under this model, both Rayleigh scattering and dipole interaction are studied between a two-level artificial atom embedded in a nanocrystal and fiber modes (guided and radiation modes). It is found that Rayleigh scattering plays a critical role in the transport properties and quantum statistics of photons. On the one hand, Rayleigh scattering produces the transparency in the optical transmitted field of the nanofiber, accompanied by the change of atomic phase, population, and frequency shift. On the other hand, the interference between two kinds of scattering fields by Rayleigh scattering and dipole transition modifies the photon statistics (second-order autocorrelation function) of output fields, showing a strong wavelength dependence. This study provides guidance for the solid-state emitter acting as a single-photon source and can be extended to explore the scattering effect in many-body physics.

  20. Operating single quantum emitters with a compact Stirling cryocooler.

    Science.gov (United States)

    Schlehahn, A; Krüger, L; Gschrey, M; Schulze, J-H; Rodt, S; Strittmatter, A; Heindel, T; Reitzenstein, S

    2015-01-01

    The development of an easy-to-operate light source emitting single photons has become a major driving force in the emerging field of quantum information technology. Here, we report on the application of a compact and user-friendly Stirling cryocooler in the field of nanophotonics. The Stirling cryocooler is used to operate a single quantum emitter constituted of a semiconductor quantum dot (QD) at a base temperature below 30 K. Proper vibration decoupling of the cryocooler and its surrounding enables free-space micro-photoluminescence spectroscopy to identify and analyze different charge-carrier states within a single quantum dot. As an exemplary application in quantum optics, we perform a Hanbury-Brown and Twiss experiment demonstrating a strong suppression of multi-photon emission events with g((2))(0) Stirling-cooled single quantum emitter under continuous wave excitation. Comparative experiments performed on the same quantum dot in a liquid helium (LHe)-flow cryostat show almost identical values of g((2))(0) for both configurations at a given temperature. The results of this proof of principle experiment demonstrate that low-vibration Stirling cryocoolers that have so far been considered exotic to the field of nanophotonics are an attractive alternative to expensive closed-cycle cryostats or LHe-flow cryostats, which could pave the way for the development of high-quality table-top non-classical light sources.

  1. Operating single quantum emitters with a compact Stirling cryocooler

    Energy Technology Data Exchange (ETDEWEB)

    Schlehahn, A.; Krüger, L.; Gschrey, M.; Schulze, J.-H.; Rodt, S.; Strittmatter, A.; Heindel, T., E-mail: tobias.heindel@tu-berlin.de; Reitzenstein, S. [Institute of Solid State Physics, Technische Universität Berlin, 10623 Berlin (Germany)

    2015-01-15

    The development of an easy-to-operate light source emitting single photons has become a major driving force in the emerging field of quantum information technology. Here, we report on the application of a compact and user-friendly Stirling cryocooler in the field of nanophotonics. The Stirling cryocooler is used to operate a single quantum emitter constituted of a semiconductor quantum dot (QD) at a base temperature below 30 K. Proper vibration decoupling of the cryocooler and its surrounding enables free-space micro-photoluminescence spectroscopy to identify and analyze different charge-carrier states within a single quantum dot. As an exemplary application in quantum optics, we perform a Hanbury-Brown and Twiss experiment demonstrating a strong suppression of multi-photon emission events with g{sup (2)}(0) < 0.04 from this Stirling-cooled single quantum emitter under continuous wave excitation. Comparative experiments performed on the same quantum dot in a liquid helium (LHe)-flow cryostat show almost identical values of g{sup (2)}(0) for both configurations at a given temperature. The results of this proof of principle experiment demonstrate that low-vibration Stirling cryocoolers that have so far been considered exotic to the field of nanophotonics are an attractive alternative to expensive closed-cycle cryostats or LHe-flow cryostats, which could pave the way for the development of high-quality table-top non-classical light sources.

  2. Transfer mechanisms between emitter molecules for OLED applications

    Energy Technology Data Exchange (ETDEWEB)

    Steinbacher, Frank [Department of Materials Science VI, University of Erlangen-Nuernberg (Germany); Siemens AG, CT MM 1, Erlangen (Germany); Chiu, Chien-Shu [Department of Electrical Engineering and Information Technology, Technical University of Braunschweig (Germany); Siemens AG, CT MM 1, Erlangen (Germany); Krause, Ralf; Hunze, Arvid [Siemens AG, CT MM 1, Erlangen (Germany); Winnacker, Albrecht [Department of Materials Science VI, University of Erlangen-Nuernberg (Germany)

    2009-07-01

    Within the last few years white organic light emitting diodes based on small molecules have shown the potential to have a promising future in the field of lighting technology. Nevertheless there is still room for improvement of the overall efficiency and lifetime of white OLEDs. A deeper understanding of the energy transfer mechanisms between different matrix and emitter molecules used in the OLED stack concept can help to optimize the layout and reduce driving voltage thus increasing the power efficiency and color stability of the device. To simplify the complex interactions within a complete white OLED we start out with a basic model system only containing the molecules of interest. This enables us to predict the fundamental concepts causing the behavior of more intricate systems. Using photoluminescence, excitation spectra and time-resolved photoluminescence we investigated the exciton transfer between different dyes for a variety of emitter systems. Our results indicate a dependence of exciton transfer probability on the total concentrations and therefore the distance between the molecules involved.

  3. Discrete space charge affected field emission: Flat and hemisphere emitters

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, Kevin L., E-mail: kevin.jensen@nrl.navy.mil [Code 6854, Naval Research Laboratory, Washington, DC 20375 (United States); Shiffler, Donald A.; Tang, Wilkin [Air Force Research Laboratory, Kirtland AFB, New Mexico 87117 (United States); Rittersdorf, Ian M. [Code 6770, Naval Research Laboratory, Washington, DC 20375 (United States); Lebowitz, Joel L. [Department of Mathematics and Department of Physics, Rutgers University, Piscataway, New Jersey 08854-8019 (United States); Harris, John R. [U.S. Navy Reserve, New Orleans, Louisiana 70143 (United States); Lau, Y. Y. [Department of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, Michigan 48109 (United States); Petillo, John J. [Leidos, Billerica, Massachusetts 01821 (United States); Luginsland, John W. [Physics and Electronics Directorate, AFOSR, Arlington, Virginia 22203 (United States)

    2015-05-21

    Models of space-charge affected thermal-field emission from protrusions, able to incorporate the effects of both surface roughness and elongated field emitter structures in beam optics codes, are desirable but difficult. The models proposed here treat the meso-scale diode region separate from the micro-scale regions characteristic of the emission sites. The consequences of discrete emission events are given for both one-dimensional (sheets of charge) and three dimensional (rings of charge) models: in the former, results converge to steady state conditions found by theory (e.g., Rokhlenko et al. [J. Appl. Phys. 107, 014904 (2010)]) but show oscillatory structure as they do. Surface roughness or geometric features are handled using a ring of charge model, from which the image charges are found and used to modify the apex field and emitted current. The roughness model is shown to have additional constraints related to the discrete nature of electron charge. The ability of a unit cell model to treat field emitter structures and incorporate surface roughness effects inside a beam optics code is assessed.

  4. A Laboratory Goniometer System for Measuring Reflectance and Emittance Anisotropy

    Directory of Open Access Journals (Sweden)

    Arjan de Jong

    2012-12-01

    Full Text Available In this paper, a laboratory goniometer system for performing multi-angular measurements under controlled illumination conditions is described. A commercially available robotic arm enables the acquisition of a large number of measurements over the full hemisphere within a short time span making it much faster than other goniometers. In addition, the presented set-up enables assessment of anisotropic reflectance and emittance behaviour of soils, leaves and small canopies. Mounting a spectrometer enables acquisition of either hemispherical measurements or measurements in the horizontal plane. Mounting a thermal camera allows directional observations of the thermal emittance. This paper also presents three showcases of these different measurement set-ups in order to illustrate its possibilities. Finally, suggestions for applying this instrument and for future research directions are given, including linking the measured reflectance anisotropy with physically-based anisotropy models on the one hand and combining them with field goniometry measurements for joint analysis with remote sensing data on the other hand. The speed and flexibility of the system offer a large added value to the existing pool of laboratory goniometers.

  5. International workshop on emittance preservation in linear colliders

    International Nuclear Information System (INIS)

    Urakawa, Junji; Oide, Katsunobu

    1993-09-01

    The extremely low emittances, which are the essential feature for any linear collider, are far beyond those of the present high-energy accelerators. Every part of the linear-collider accelerator complex is liable to blow up them to a fatal degree. Above all, the main linac is the most critical part, since it will have an unprecedented length, through which very highly populated bunches should be accelerated without a faint increase of emittances. A lot of efforts have been paid, mainly theoretically, to settle this problem at all institutes. Any convincing conclusions are not yet reached. Furthermore, there are six approaches of substantially different schemes (Tesla, DLC, JLC, NLC, VLEPP, CLIC), each requiring its own way to tackle the problem. In this workshop, many up-to-date R and D results were presented by each institute. Judging from what were discussed, we may well say that the R and D work has advanced to such a level that the different approaches are rather helping each other to reach more concrete results. (J.P.N.)

  6. La Ha de la infancia en Italia. Problemas y perspectiva

    Directory of Open Access Journals (Sweden)

    Enzo CATARSI

    2010-03-01

    Full Text Available RESUMEN: La historiografía italiana de la infancia, como la de otros muchos países europeos, está hoy embarcada en una tarea de desarrollo y profundización que permitirá recuperar los retrasos que la han caracterizado. En efecto, también en Italia la historia de la infancia y su individuación como «objeto» historiografía constituyen una adquisición reciente, lograda con la ayuda de diversas influencias. La primera, estrechamente vinculada a la historia de las mentalidades, representada por la obra de Ph. Aries, «El niño y la vida familiar en el Antiguo Régimen», traducido al italiano en 1968. La segunda es la historia social, orientada al estudio de los diversos aspectos de la vida de una sociedad, y más atenta a sus acontecimientos. La tercera la representa el estructuralismo, especialmente el francés, y en concreto M. Foucault. La particular influencia que, también en el contexto italiano, han alcanzado los trabajos de Ph. Aries y L. DeMause, muy importantes por haber abierto una línea de investigación, aunque con las obligadas diferencias, ha conducido a privilegiar una perspectiva exclusiva de historia de las mentalidades que se muestra muy ambigua y claramente interpretativa en exceso.

  7. Prediction of IOI-HA Scores Using Speech Reception Thresholds and Speech Discrimination Scores in Quiet

    DEFF Research Database (Denmark)

    Brännström, K Jonas; Lantz, Johannes; Nielsen, Lars Holme

    2014-01-01

    ), and speech discrimination scores (SDSs) in quiet or in noise are common assessments made prior to hearing aid (HA) fittings. It is not known whether SRT and SDS in quiet relate to HA outcome measured with the International Outcome Inventory for Hearing Aids (IOI-HA). PURPOSE: The aim of the present study...... COLLECTION AND ANALYSIS: The psychometric properties were evaluated and compared to previous studies using the IOI-HA. The associations and differences between the outcome scores and a number of descriptive variables (age, gender, fitted monaurally/binaurally with HA, first-time/experienced HA users, years...

  8. New three-count technique for short-lived radon decay products in air

    International Nuclear Information System (INIS)

    Tian Deyuan; Lu Zhizhao

    1998-01-01

    Up to the present, radon and its short-lived decay products in air are usually monitored by means of a detection. But radon progeny, including RaB ( 214 Pb) and RaC ( 214 Bi) which are β and γ emitters, contribute about 90% to the equilibrium equivalent radon concentration (EECRn). Therefore, this paper introduces a new three-count technique by a β detector in the light of radioactive decay law and its boundary conditions during sampling and counting times to solve the Bateman equation. β (even low level β) instruments have been fairly popularized domestically and internationally. It can be used not only as an instrument for radon and its daughters in air, but also as a monitor for β airborne activity in the environment. This new method taps further the latent power of the present instrument and realizes various uses for a unit. (author)

  9. Theory of photoelectron counting statistics

    International Nuclear Information System (INIS)

    Blake, J.

    1980-01-01

    The purpose of the present essay is to provide a detailed analysis of those theoretical aspects of photoelectron counting which are capable of experimental verification. Most of our interest is in the physical phenomena themselves, while part is in the mathematical techniques. Many of the mathematical methods used in the analysis of the photoelectron counting problem are generally unfamiliar to physicists interested in the subject. For this reason we have developed the essay in such a fashion that, although primary interest is focused on the physical phenomena, we have also taken pains to carry out enough of the analysis so that the reader can follow the main details. We have chosen to present a consistently quantum mechanical version of the subject, in that we follow the Glauber theory throughout. (orig./WL)

  10. Bayesian Kernel Mixtures for Counts.

    Science.gov (United States)

    Canale, Antonio; Dunson, David B

    2011-12-01

    Although Bayesian nonparametric mixture models for continuous data are well developed, there is a limited literature on related approaches for count data. A common strategy is to use a mixture of Poissons, which unfortunately is quite restrictive in not accounting for distributions having variance less than the mean. Other approaches include mixing multinomials, which requires finite support, and using a Dirichlet process prior with a Poisson base measure, which does not allow smooth deviations from the Poisson. As a broad class of alternative models, we propose to use nonparametric mixtures of rounded continuous kernels. An efficient Gibbs sampler is developed for posterior computation, and a simulation study is performed to assess performance. Focusing on the rounded Gaussian case, we generalize the modeling framework to account for multivariate count data, joint modeling with continuous and categorical variables, and other complications. The methods are illustrated through applications to a developmental toxicity study and marketing data. This article has supplementary material online.

  11. Card counting in continuous time

    OpenAIRE

    Andersson, Patrik

    2012-01-01

    We consider the problem of finding an optimal betting strategy for a house-banked casino card game that is played for several coups before reshuffling. The sampling without replacement makes it possible to take advantage of the changes in the expected value as the deck is depleted, making large bets when the game is advantageous. Using such a strategy, which is easy to implement, is known as card counting. We consider the case of a large number of decks, making an approximat...

  12. Monitoring Milk Somatic Cell Counts

    Directory of Open Access Journals (Sweden)

    Gheorghe Şteţca

    2014-11-01

    Full Text Available The presence of somatic cells in milk is a widely disputed issue in milk production sector. The somatic cell counts in raw milk are a marker for the specific cow diseases such as mastitis or swollen udder. The high level of somatic cells causes physical and chemical changes to milk composition and nutritional value, and as well to milk products. Also, the mastitic milk is not proper for human consumption due to its contribution to spreading of certain diseases and food poisoning. According to these effects, EU Regulations established the maximum threshold of admitted somatic cells in raw milk to 400000 cells / mL starting with 2014. The purpose of this study was carried out in order to examine the raw milk samples provided from small farms, industrial type farms and milk processing units. There are several ways to count somatic cells in milk but the reference accepted method is the microscopic method described by the SR EN ISO 13366-1/2008. Generally samples registered values in accordance with the admissible limit. By periodical monitoring of the somatic cell count, certain technological process issues are being avoided and consumer’s health ensured.

  13. Application of the 4 {sup {pi}{sup {gamma}}} Method to the Absolute Standardization of Radioactive Sources of Positron Emitters; Aplicacion del Metodo 4 {sup {pi}{sup {gamma}}} a la Medida Absoluta de la Actividad de Fuentes Radiactivas Emisoras de Positrones

    Energy Technology Data Exchange (ETDEWEB)

    Peyres Medina, V.; Garcia-Torano Martinez, E.; Roteta Ibarra, M.

    2006-07-01

    We discuss the application of the method known as 4 {sup {pi}{sup {gamma}}} counting to the standardization of positron emitters. Monte Carlo simulations are used to calculate the detection efficiency of positrons emitted by the nuclides 22Na and 18F. Two experimental setups are used, both based on a NaI(Tl) well detector. The results of the standardizations are in good agreement with those obtained by other methods. It is shown that the 4 {sup {pi}{sup {gamma}}} method can be successfully used for the absolute standardization of sources of positron emitters. (Author) 23 refs.

  14. Enantiomers of HA-966 (3-amino-1-hydroxypyrrolid-2-one) exhibit distinct central nervous system effects: (+)-HA-966 is a selective glycine/N-methyl-D-aspartate receptor antagonist, but (-)-HA-966 is a potent gamma-butyrolactone-like sedative

    International Nuclear Information System (INIS)

    Singh, L.; Donald, A.E.; Foster, A.C.; Hutson, P.H.; Iversen, L.L.; Iversen, S.D.; Kemp, J.A.; Leeson, P.D.; Marshall, G.R.; Oles, R.J.; Priestley, T.; Thorn, L.; Tricklebank, M.D.; Vass, C.A.; Williams, B.J.

    1990-01-01

    The antagonist effect of ±-3-amino-1-hydroxypyrrolid-2-one (HA-966) at the N-methyl-D-aspartate (NMDA) receptor occurs through a selective interaction with the glycine modulatory site within the receptor complex. When the enantiomers of ±-HA-966 were resolved, the (R)-(+)-enantiomer was found to be a selective glycine/NMDA receptor antagonist, a property that accounts for its anticonvulsant activity in vivo. In contrast, the (S)-(-)-enantiomer was only weakly active as an NMDA-receptor antagonist, but nevertheless it possessed a marked sedative and muscle relaxant action in vivo. In radioligand binding experiments, (+)-HA-966 inhibited strychnine-insensitive [ 3 H]glycine binding to rat cerebral cortex synaptic membranes with an IC 50 of 12.5 μM, whereas (-)-HA-966 had an IC 50 value of 339 μM. In mice, (+)-HA-966 antagonized sound and N-methyl-DL-aspartic acid (NMDLA)-induced seizures. The coadministration of D-serine dose-dependently antagonized the anticonvulsant effect of a submaximal dose of (+)-HA-966 against NMDLA-induced seizures. The sedative/ataxic effect of racemic HA-966 was mainly attributable to the (-)-enantiomer. It is suggested that, as in the case of the sedative γ-butyrolactone, disruption of striatal dopaminergic mechanisms may be responsible for this action

  15. Tunable, Room Temperature THZ Emitters Based on Nonlinear Photonics

    Science.gov (United States)

    Sinha, Raju

    The Terahertz (1012 Hz) region of the electromagnetic spectrum covers the frequency range from roughly 300 GHz to 10 THz, which is in between the microwave and infrared regimes. The increasing interest in the development of ultra-compact, tunable room temperature Terahertz (THz) emitters with wide-range tunability has stimulated in-depth studies of different mechanisms of THz generation in the past decade due to its various potential applications such as biomedical diagnosis, security screening, chemical identification, life sciences and very high speed wireless communication. Despite the tremendous research and development efforts, all the available state-of-the-art THz emitters suffer from either being large, complex and costly, or operating at low temperatures, lacking tunability, having a very short spectral range and a low output power. Hence, the major objective of this research was to develop simple, inexpensive, compact, room temperature THz sources with wide-range tunability. We investigated THz radiation in a hybrid optical and THz micro-ring resonators system. For the first time, we were able to satisfy the DFG phase matching condition for the above-mentioned THz range in one single device geometry by employing a modal phase matching technique and using two separately designed resonators capable of oscillating at input optical waves and generated THz waves. In chapter 6, we proposed a novel plasmonic antenna geometry – the dimer rod-tapered antenna (DRTA), where we created a hot-spot in the nanogap between the dimer arms with a very large intensity enhancement of 4.1x105 at optical resonant wavelength. Then, we investigated DFG operation in the antenna geometry by incorporating a nonlinear nanodot in the hot-spot of the antenna and achieved continuously tunable enhanced THz radiation across 0.5-10 THz range. In chapter 8, we designed a multi-metallic resonators providing an ultrasharp toroidal response at THz frequency, then fabricated and

  16. Semiconductor Quantum Dash Broadband Emitters: Modeling and Experiments

    KAUST Repository

    Khan, Mohammed Zahed Mustafa

    2013-10-01

    Broadband light emitters operation, which covers multiple wavelengths of the electromagnetic spectrum, has been established as an indispensable element to the human kind, continuously advancing the living standard by serving as sources in important multi-disciplinary field applications such as biomedical imaging and sensing, general lighting and internet and mobile phone connectivity. In general, most commercial broadband light sources relies on complex systems for broadband light generation which are bulky, and energy hungry. \\tRecent demonstration of ultra-broadband emission from semiconductor light sources in the form of superluminescent light emitting diodes (SLDs) has paved way in realization of broadband emitters on a completely novel platform, which offered compactness, cost effectiveness, and comparatively energy efficient, and are already serving as a key component in medical imaging systems. The low power-bandwidth product is inherent in SLDs operating in the amplified spontaneous emission regime. A quantum leap in the advancement of broadband emitters, in which high power and large bandwidth (in tens of nm) are in demand. Recently, the birth of a new class of broadband semiconductor laser diode (LDs) producing multiple wavelength light in stimulated emission regime was demonstrated. This very recent manifestation of a high power-bandwidth-product semiconductor broadband LDs relies on interband optical transitions via quantum confined dot/dash nanostructures and exploiting the natural inhomogeneity of the self-assembled growth technology. This concept is highly interesting and extending the broad spectrum of stimulated emission by novel device design forms the central focus of this dissertation. \\tIn this work, a simple rate equation numerical technique for modeling InAs/InP quantum dash laser incorporating the properties of inhomogeneous broadening effect on lasing spectra was developed and discussed, followed by a comprehensive experimental analysis

  17. Drip irrigation emitter clogging in Dutch greenhouses as affected by methane and organic acids

    NARCIS (Netherlands)

    Kreij, de C.; Burg, van der A.M.M.; Runia, W.T.

    2003-01-01

    It is believed that the serious clogging of drip irrigation emitters in the Dutch greenhouse industry is caused by methane-oxidising bacteria and/or organic acids used as anti-clogging agents. In this study greenhouses with moderate to severe emitter clogging have been examined. High methane

  18. Chemically doped three-dimensional porous graphene monoliths for high-performance flexible field emitters.

    Science.gov (United States)

    Kim, Ho Young; Jeong, Sooyeon; Jeong, Seung Yol; Baeg, Kang-Jun; Han, Joong Tark; Jeong, Mun Seok; Lee, Geon-Woong; Jeong, Hee Jin

    2015-03-12

    Despite the recent progress in the fabrication of field emitters based on graphene nanosheets, their morphological and electrical properties, which affect their degree of field enhancement as well as the electron tunnelling barrier height, should be controlled to allow for better field-emission properties. Here we report a method that allows the synthesis of graphene-based emitters with a high field-enhancement factor and a low work function. The method involves forming monolithic three-dimensional (3D) graphene structures by freeze-drying of a highly concentrated graphene paste and subsequent work-function engineering by chemical doping. Graphene structures with vertically aligned edges were successfully fabricated by the freeze-drying process. Furthermore, their number density could be controlled by varying the composition of the graphene paste. Al- and Au-doped 3D graphene emitters were fabricated by introducing the corresponding dopant solutions into the graphene sheets. The resulting field-emission characteristics of the resulting emitters are discussed. The synthesized 3D graphene emitters were highly flexible, maintaining their field-emission properties even when bent at large angles. This is attributed to the high crystallinity and emitter density and good chemical stability of the 3D graphene emitters, as well as to the strong interactions between the 3D graphene emitters and the substrate.

  19. High precision wavefront control in point spread function engineering for single emitter localization

    NARCIS (Netherlands)

    Siemons, M.E.; Thorsen, R.Ø; Smith, C.S.; Stallinga, S.

    2018-01-01

    Point spread function (PSF) engineering is used in single emitter localization to measure the emitter position in 3D and possibly other parameters such as the emission color or dipole orientation as well. Advanced PSF models such as spline fits to experimental PSFs or the vectorial PSF model can

  20. Integrated circuits with emitter coupling and their application in nanosecond nuclear electronics

    International Nuclear Information System (INIS)

    Basiladze, S.G.

    1976-01-01

    Principal static and dynamic characteristics are considered of integrated circuits with emitter coupling, as well as problems of signal transmission. Diagrams are given of amplifiers, discriminators, time interval drivers, generators, etc. Systems and units of nanosecond electronics employing integrated circuits with emitter coupling are briefly described