WorldWideScience

Sample records for h-alpha emitter count

  1. Continuous monitoring for airborne alpha emitters in a dusty environment

    International Nuclear Information System (INIS)

    Seiler, F.A.; Newton, G.J.; Guilmette, R.A.

    1988-01-01

    Disposal of radioactive wastes in underground facilities requires continuous monitoring for airborne radioactive materials, both on the surface and underground. In addition to a natural background of nonradioactive and radioactive aerosols, there may be a sizeable dust contribution from ongoing work such as mining and vehicular traffic. In the monitoring of alpha-emitting radionuclides, these aerosols may lead to self-absorption in the source and a deterioration of the energy spectrum of the detected alpha particles. In this paper, the influence of a realistic background aerosol on the performance of an alpha monitoring system is evaluated theoretically. It is shown that depositing alpha emitters and background aerosol on a surface for counting leads rapidly to a considerable loss of counts, a deterioration of the alpha spectra, an eventual saturation of the count rates, and interference from the natural background of Rn daughters

  2. Preliminary studies for the determination of alpha emitters using the gross alpha coprecipitation methods

    International Nuclear Information System (INIS)

    Suarez-Navarro, J. A.; Pujol, L.; Suarez, J. A.; Pablo, M. A. de

    2003-01-01

    The radiological quality of drinking water in Spain is regulated by Nuclear Security Guideline No, 7.7 (Rev.1) of the Nuclear Security Council (NSC). this guideline establishes the protocol to follow when the radiological level exceeds 0,1 Bq.l''1. When this level is passed, the responsible alpha emitter must be identified; ''210 Po, ''226Ra, ''230Th, ''239Pu, ''224Ra, ''234 U and ''138 U. Activity due to these isotopes is usually determined using alpha spectrometry with semiconductor detectors. This method allows the activity of the alpha emitters to be determined with a good sensitivity. however, it requires long radiochemical isolations and long counting times, so the method is not suitable for rough estimate radiological analysis. In this preliminary work, we present the conditioning of the sample-precipitate that is essential for further radiochemical isolations. (Author) 9 refs

  3. Liquid scintillation counting techniques for the determination of some alpha emitting actinides: a review

    International Nuclear Information System (INIS)

    Mirashi, N.N.; Chander, Keshav; Aggarwal, S.K.

    2000-12-01

    The present report is a review of the work on liquid scintillation counting techniques, for the determination of alpha emitting actinides like uranium, plutonium, americium etc; for the last three decades (1970-1999). It covers the progress that has taken place in conventional liquid scintillation counting employing various solvents, scintillators and extractants. There is gradual development in instrumentation from integral counting of alpha emitters to alpha liquid scintillation spectrometry to resolve and identify different alpha emitters. These advancements have led to Pulse Shape Analysis (PSA) and Photon Electron Rejecting Alpha Liquid Scintillation Spectrometry (PERALS) techniques for the determination of the alpha emitters in the presence of beta and gamma activity. These techniques allow the determination of actinides at very low levels which has increased their applications to almost all the fields of chemistry; be it biomedical, environmental, geological or process chemistry of nuclear fuels. The development of biphasic technique using various extractants to separate different elements and counting in presence of one another has been made possible. Inorganic scintillators have been recently developed which have the advantage of eliminating effects of quenching and presence of beta/gamma emitting actinides. This review will serve as a reference to those who want to carry out work in the field of determination of actinides using liquid scintillation counting techniques. (author)

  4. Discriminator setting and cocktail preparation for analysis of alpha and beta emitters in aqueous solution using liquid scintillation counter

    International Nuclear Information System (INIS)

    Zaini Hamzah; Masitah Alias; Zaharudin Ahmad

    2011-01-01

    Liquid scintillation counting (LSC) is not only being used to measure pure beta emitters, but it can be used to measure both alpha and beta emitters simultaneously. Measurement of alpha and beta emitters in aqueous solution is done using a single sample. For the sample preparation, colorless detergent or emulsifier was used to incorporate the water into an organic based scintillator to produce a clear homogeneous solution, since this is the best form to give the highest count rate and detection efficiency. The instrument also need some attention, where after calibration, the LSC was set for the discriminator level which is suitable for measurement of both alpha and beta radiations. In this study, the focus is on the development of the best scintillation cocktail and establishes the best discriminator setting. From this study the best proportion of scintillation cocktail is 2:4:4 for water, toluene, and Triton-N101 (emulsifier) respectively and the best discriminator setting for alpha and beta counting are 120. (author)

  5. Alpha particle emitters in medicine

    International Nuclear Information System (INIS)

    Fisher, D.R.

    1989-09-01

    Radiation-induced cancer of bone, liver and lung has been a prominent harmful side-effect of medical applications of alpha emitters. In recent years, however, the potential use of antibodies labeled with alpha emitting radionuclides against cancer has seemed promising because alpha particles are highly effective in cell killing. High dose rates at high LET, effectiveness under hypoxic conditions, and minimal expectancy of repair are additional advantages of alpha emitters over antibodies labeled with beta emitting radionuclides for cancer therapy. Cyclotron-produced astatine-211 ( 211 At) and natural bismuth-212 ( 212 Bi) have been proposed and are under extensive study in the United States and Europe. Radium-223 ( 223 Ra) also has favorable properties as a potential alpha emitting label, including a short-lived daughter chain with four alpha emissions. The radiation dosimetry of internal alpha emitters is complex due to nonuniformly distributed sources, short particle tracks, and high relative specific ionization. The variations in dose at the cellular level may be extreme. Alpha-particle radiation dosimetry, therefore, must involve analysis of statistical energy deposition probabilities for cellular level targets. It must also account fully for nonuniform distributions of sources in tissues, source-target geometries, and particle-track physics. 18 refs., 4 figs

  6. Production of alpha emitters for therapy

    International Nuclear Information System (INIS)

    Vucina, J.; Orlic, M.; Lukic, D.

    2006-01-01

    The basis for the introduction of alpha emitters into nuclear medical practice are their radiobiological properties. High LET values and short ranges in biological tissues are advantageous in comparison with nowadays most often used beta emitters, primarily 90 Y and 131 I. Given are the most important criteria for the introduction of a given radionuclide in the routine use. Shown are the procedures for the production of the most important alpha emitters 211 At, 212 Bi and 213 Bi. (author)

  7. Alpha-emitters for medical therapy workshop

    International Nuclear Information System (INIS)

    Feinendegen, L.E.; McClure, J.J.

    1996-01-01

    A workshop on ''Alpha-Emitters for Medical Therapy'' was held May 30-31, 1996 in Denver Colorado to identify research goals and potential clinical needs for applying alpha-particle emitters and to provide DOE with sufficient information for future planning. The workshop was attended by 36 participants representing radiooncology, nuclear medicine, immunotherapy, radiobiology, molecular biology, biochemistry, radiopharmaceutical chemistry, dosimetry, and physics. This report provides a summary of the key points and recommendations arrived at during the conference

  8. Alpha-emitters for medical therapy workshop

    Energy Technology Data Exchange (ETDEWEB)

    Feinendegen, L.E.; McClure, J.J.

    1996-12-31

    A workshop on ``Alpha-Emitters for Medical Therapy`` was held May 30-31, 1996 in Denver Colorado to identify research goals and potential clinical needs for applying alpha-particle emitters and to provide DOE with sufficient information for future planning. The workshop was attended by 36 participants representing radiooncology, nuclear medicine, immunotherapy, radiobiology, molecular biology, biochemistry, radiopharmaceutical chemistry, dosimetry, and physics. This report provides a summary of the key points and recommendations arrived at during the conference.

  9. Cancer therapy with alpha-emitters labeled peptides.

    Science.gov (United States)

    Dadachova, Ekaterina

    2010-05-01

    Actively targeted alpha-particles offer specific tumor cell killing action with less collateral damage to surrounding normal tissues than beta-emitters. During the last decade, radiolabeled peptides that bind to different receptors on the tumors have been investigated as potential therapeutic agents both in the preclinical and clinical settings. Advantages of radiolabeled peptides over antibodies include relatively straightforward chemical synthesis, versatility, easier radiolabeling, rapid clearance from the circulation, faster penetration and more uniform distribution into tissues, and less immunogenicity. Rapid internalization of the radiolabeled peptides with equally rapid re-expression of the cell surface target is a highly desirable property that enhances the total delivery of these radionuclides into malignant sites. Peptides, such as octreotide, alpha-melanocyte-stimulating hormone analogues, arginine-glycine-aspartic acid-containing peptides, bombesin derivatives, and others may all be feasible for use with alpha-emitters. The on-going preclinical work has primarily concentrated on octreotide and octreotate analogues labeled with Bismuth-213 and Astatine-211. In addition, alpha-melanocyte-stimulating hormone analogue has been labeled with Lead-212/Bismuth-212 in vivo generator and demonstrated the encouraging therapeutic efficacy in treatment of experimental melanoma. Obstacles that continue to obstruct widespread acceptance of alpha-emitter-labeled peptides are primarily the supply of these radionuclides and concerns about potential kidney toxicity. New sources and methods for production of these medically valuable radionuclides and better understanding of mechanisms related to the peptide renal uptake and clearance should speed up the introduction of alpha-emitter-labeled peptides into the clinic. Copyright 2010 Elsevier Inc. All rights reserved.

  10. Fitting of alpha-efficiency versus quenching parameter by exponential functions in liquid scintillation counting

    International Nuclear Information System (INIS)

    Sosa, M.; Manjón, G.; Mantero, J.; García-Tenorio, R.

    2014-01-01

    The objective of this work is to propose an exponential fit for the low alpha-counting efficiency as a function of a sample quenching parameter using a Quantulus liquid scintillation counter. The sample quenching parameter in a Quantulus is the Spectral Quench Parameter of the External Standard (SQP(E)), which is defined as the number of channel under which lies the 99% of Compton spectrum generated by a gamma emitter ( 152 Eu). Although in the literature one usually finds a polynomial fitting of the alpha counting efficiency, it is shown here that an exponential function is a better description. - Highlights: • We have studied the quenching in alpha measurement by liquid scintillation counting. • We have reviewed typical fitting of alpha counting efficiency versus quenching parameter. • Exponential fitting of data is proposed as better fitting. • We consider exponential fitting has a physical basis

  11. Fitting of alpha-efficiency versus quenching parameter by exponential functions in liquid scintillation counting

    Energy Technology Data Exchange (ETDEWEB)

    Sosa, M. [Departamento de Ingeniería Física, Campus León, Universidad de Guanajuato, 37150 León, Guanajuato (Mexico); Universidad de Sevilla, Departamento de Física Aplicada II, E.T.S. Arquitectura, Av. Reina Mercedes, 2, 41012 Sevilla (Spain); Manjón, G., E-mail: manjon@us.es [Universidad de Sevilla, Departamento de Física Aplicada II, E.T.S. Arquitectura, Av. Reina Mercedes, 2, 41012 Sevilla (Spain); Mantero, J.; García-Tenorio, R. [Universidad de Sevilla, Departamento de Física Aplicada II, E.T.S. Arquitectura, Av. Reina Mercedes, 2, 41012 Sevilla (Spain)

    2014-05-01

    The objective of this work is to propose an exponential fit for the low alpha-counting efficiency as a function of a sample quenching parameter using a Quantulus liquid scintillation counter. The sample quenching parameter in a Quantulus is the Spectral Quench Parameter of the External Standard (SQP(E)), which is defined as the number of channel under which lies the 99% of Compton spectrum generated by a gamma emitter ({sup 152}Eu). Although in the literature one usually finds a polynomial fitting of the alpha counting efficiency, it is shown here that an exponential function is a better description. - Highlights: • We have studied the quenching in alpha measurement by liquid scintillation counting. • We have reviewed typical fitting of alpha counting efficiency versus quenching parameter. • Exponential fitting of data is proposed as better fitting. • We consider exponential fitting has a physical basis.

  12. Radon Daughters Background Reduction in Alpha Particles Counting System

    International Nuclear Information System (INIS)

    Dadon, S. S.; Pelled, O.; Orion, I.

    2014-01-01

    The ABPC method is using a serially occurring events of the beta decay of the 214Bi fallow by alpha decay of the 214Po that take place almost simultaneously to detect the Pseudo Coincidence Event (PCE) from the RDP, and to subtract them from the gross alpha counts. 267 This work showed that it is possible to improve the efficiency of RDP background reduction, including subtracting the 218Po contribution by using the ABPC method based on a single solid state silicon PIPS detector. False counts percentage obtained at the output of the PCE circuit were smaller than 0.1%. The results show that the PCE circuit was not influenced by non RDP alpha emitters. The PCE system did not reduce the non PCE of the 218Po. After 20 minutes the 218Po was strongly decayed, and its contribution became negligible. In order to overcome this disadvantage, a mathematical matching calculations for the 214Po and the 218Po decay equations were employed, and a constant ratio of the APo214(0) / APo218(0) was obtained. This ratio can be used to estimate the count rate of the 218Po at the first 20 minutes, and to subtract it from the total count rate in order to obtain correct RDP reduction

  13. Liquid scintillation alpha counting and spectrometry and its application to bone and tissue samples

    International Nuclear Information System (INIS)

    McDowell, W.J.; Weiss, J.F.

    1976-01-01

    Three methods for determination of alpha-emitting nuclides using liquid scintillation counting are compared, and the pertinent literature is reviewed. Data showing the application of each method to the measurement of plutonium concentration in tissue and bone samples are presented. Counting with a commercial beta-liquid scintillation counter and an aqueous-phase-accepting scintillator is shown to be accurate only in cases where the alpha activity is high (several hundred counts/min or more), only gross alpha counting is desired, and beta-gamma emitters are known to be absent from the sample or present at low levels compared with the alpha activity. Counting with the same equipment and an aqueous immiscible scintillator containing an extractant for the nuclide of interest (extractive scintillator) is shown to allow better control of alpha peak shift due to quenching, a significant reduction of beta-gamma interference, and, usually, a low background. The desirability of using a multichannel pulse-height analyzer in the above two counting methods is stressed. The use of equipment and procedures designed for alpha liquid scintillation counting is shown to allow alpha spectrometry with an energy resolution capability of 200 to 300 keV full-peak-width-at-half-peak-height and a background of 0.3 to 1.0 counts/min, or as low as 0.01 counts/min if pulse-shape discrimination methods are used. Methods for preparing animal bone and tissue samples for assay are described

  14. Alpha liquid scintillation counting: past, present, and future

    International Nuclear Information System (INIS)

    McDowell, W.J.

    1979-01-01

    Beta liquid scintillation counting has been used for about 30 years, and its effectiveness for alpha particles has been known for almost that long; however, the technique has not been widely applied to alpha particle detection because of poor energy resolution, high background, and variable interference from beta and gamma radiation. Beginning with the work of Horrocks in the early 1960s, improvements in energy resolution and background rejection have been made. Further developments at Oak Ridge National Laboratory over the past 10 to 12 years have resulted in improved methods of sample preparation (using liquid-liquid extraction methods to isolate the sample and introduce it into the scintillator) and better instrumentation, including electronic rejection of beta and gamma pulses. Energy resolutions of 200- to 300-keV FWHM and background counts of 0.01 cpm are now routine. Alpha liquid scintillation spectrometry is now suitable for a wide range of applications, from the accurate quantitative determination of relatively large amounts of known nuclides in laboratory-generated samples to the detection and identification of very small, subpicocurie amounts of alpha emitters in environmental-type samples. Suitable nuclide separation procedures, sample preparation methods, and instrument configurations are outlined for a variety of analyses

  15. DISSECTION OF H{alpha} EMITTERS : LOW-z ANALOGS OF z > 4 STAR-FORMING GALAXIES

    Energy Technology Data Exchange (ETDEWEB)

    Shim, Hyunjin [Department of Earth Science Education, Kyungpook National University (Korea, Republic of); Chary, Ranga-Ram, E-mail: hjshim@knu.ac.kr [U.S. Planck Data Center, California Institute of Technology, MS 220-6, Pasadena, CA 91125 (United States)

    2013-03-01

    Strong H{alpha} emitters (HAEs) dominate the z {approx} 4 Lyman-break galaxy (LBG) population. We have identified local analogs of these HAEs using the Sloan Digital Sky Survey. At z < 0.4, only 0.04% of the galaxies are classified as HAEs with H{alpha} equivalent widths ({approx}> 500 A) comparable to that of z {approx} 4 HAEs. Local HAEs have lower stellar mass and lower ultraviolet (UV) luminosity than z {approx} 4 HAEs, yet the H{alpha}-to-UV luminosity ratio, as well as their specific star formation rate, is consistent with that of z {approx} 4 HAEs, indicating that they are scaled-down versions of high-z star-forming galaxies. Compared to the previously studied local analogs of LBGs selected using rest-frame UV properties, local HAEs show similar UV luminosity surface density, weaker D{sub n} (4000) break, lower metallicity, and lower stellar mass. This implies that the local HAEs are less evolved galaxies than the traditional Lyman break analogs. In the stacked spectrum, local HAEs show a significant He II {lambda}4686 emission line suggesting a population of hot, massive stars similar to that seen in some Wolf-Rayet galaxies. Low [N II]/[O III] line flux ratios imply that local HAEs are inconsistent with being systems that host bright active galactic nuclei. Instead, it is highly likely that local HAEs are galaxies with an elevated ionization parameter, either due to a high electron density or large escape fraction of hydrogen ionizing photons as in the case of Wolf-Rayet galaxies.

  16. Role of quenching on alpha/beta separation in liquid scintillation counting for several high capacity cocktails

    International Nuclear Information System (INIS)

    Pujol, L.; Sanchez-Cabeza, J.-A.

    1997-01-01

    The optimization of alpha/beta separation in liquid scintillation using pulse shape analysis is convenient for the simultaneous determination of alpha and beta emitters in natural water and other samples. In this work, alpha/beta separation was studied for different scintillant/vial combinations and it was observed that both the optimum pulse shape discrimination level and the total interference value (that is, the summed relative interference between alpha and beta spectra) were dependent on the sample quenching and independent of the scintillant/vial combination. These results provide a simple method for modifying the counting configuration, such as a change in the cocktail, vial or sample characteristics, without the need to perform exhaustive parameter optimizations. Also, it was observed that, for our counting conditions, the combination of Ultima Gold AB scintillation cocktail with Zinsser low diffusion vials presented the lowest total interference, namely 0.94 ± 0.28%, which is insignificant for the counting of environmental samples. (Author)

  17. Interactive session: alpha emitters, fashion or reality? radionuclides and molecules availability

    International Nuclear Information System (INIS)

    Zimmermann, R.

    2015-01-01

    Full text of publication follows. This introduction to the interactive session will simply be based on statements related to the future of therapy in nuclear medicine with some emphasis on the use of alpha-emitters. Some hypotheses will be developed on topics such as 'How will look nuclear medicine in 2025?', 'Do we have enough information to support the use of alpha in therapy?' 'Does it make sense to develop alpha-labelled molecules without long term financial commitment?', 'Will sufficient amounts of radionuclides available when the drugs will be ready for marketing?', 'Do we know enough about alpha emitters toxicity?', 'Is personalized medicine really the solution of the future of health care?', 'How can we convince authorities about the advantages of alpha labelled molecules?', 'Is the development of alpha RIT more expensive or more difficult than beta RIT?', 'Where are all the beta-emitter under development gone?', 'With alpha-emitters, are we speaking about 2025 or 2050?', 'Will Xofigo be a success?', 'What will be the real role of pharmaceutical companies in radiotherapy?', 'Who are the most afraid about radioactivity, the patients or the authorities?'. The speaker will provide his own opinion about each topic. Will you agree or not with him? What is your opinion? (author)

  18. Alpha-particle autoradiography by solid state track detectors to spatial distribution of radioactivity in alpha-counting source

    International Nuclear Information System (INIS)

    Ishigure, Nobuhito; Nakano, Takashi; Enomoto, Hiroko; Koizumi, Akira; Miyamoto, Katsuhiro

    1989-01-01

    A technique of autoradiography using solid state track detectors is described by which spatial distribution of radioactivity in an alpha-counting source can easily be visualized. As solid state track detectors, polymer of allyl diglycol carbonate was used. The advantage of the present technique was proved that alpha-emitters can be handled in the light place alone through the whole course of autoradiography, otherwise in the conventional autoradiography the alpha-emitters, which requires special carefulness from the point of radiation protection, must be handled in the dark place with difficulty. This technique was applied to rough examination of self-absorption of the plutonium source prepared by the following different methods; the source (A) was prepared by drying at room temperature, (B) by drying under an infrared lamp, (C) by drying in ammonia atmosphere after redissolving by the addition of a drop of distilled water which followed complete evaporation under an infrared lamp and (D) by drying under an infrared lamp after adding a drop of diluted neutral detergent. The difference in the spatial distributions of radioactivity could clearly be observed on the autoradiographs. For example, the source (C) showed the most diffuse distribution, which suggested that the self-absorption of this source was the smallest. The present autoradiographic observation was in accordance with the result of the alpha-spectrometry with a silicon surface-barrier detector. (author)

  19. Method validation to determine total alpha beta emitters in water samples using LSC

    International Nuclear Information System (INIS)

    Al-Masri, M. S.; Nashawati, A.; Al-akel, B.; Saaid, S.

    2006-06-01

    In this work a method was validated to determine gross alpha and beta emitters in water samples using liquid scintillation counter. 200 ml of water from each sample were evaporated to 20 ml and 8 ml of them were mixed with 12 ml of the suitable cocktail to be measured by liquid scintillation counter Wallac Winspectral 1414. The lower detection limit by this method (LDL) was 0.33 DPM for total alpha emitters and 1.3 DPM for total beta emitters. and the reproducibility limit was (± 2.32 DPM) and (±1.41 DPM) for total alpha and beta emitters respectively, and the repeatability limit was (±2.19 DPM) and (±1.11 DPM) for total alpha and beta emitters respectively. The method is easy and fast because of the simple preparation steps and the large number of samples that can be measured at the same time. In addition, many real samples and standard samples were analyzed by the method and showed accurate results so it was concluded that the method can be used with various water samples. (author)

  20. The influence of the calibration standard and the chemical composition of the water samples residue in the counting efficiency of proportional detectors for gross alpha and beta counting. Application on the radiologic control of the IPEN-CNEN/SP

    International Nuclear Information System (INIS)

    Santos, Cecilia Martins

    2003-01-01

    In this work the efficiency calibration curves of thin-window and low background gas-flow proportional counters were determined for calibration standards with different energies and different absorber thicknesses. For the gross alpha counting we have used 241 Am and natural uranium standards and for the gross beta counting we have used 90 Sr/ 90 Y and 137 Cs standards in residue thicknesses ranging from 0 to approximately 18 mg/cm 2 . These sample thicknesses were increased with a previously determined salted solution prepared simulating the chemical composition of the underground water of IPEN The counting efficiency for alpha emitters ranged from 0,273 +- 0,038 for a weightless residue to only 0,015 +- 0,002 in a planchet containing 15 mg/cm 2 of residue for 241 Am standard. For natural uranium standard the efficiency ranged from 0,322 +- 0,030 for a weightless residue to 0,023 +- 0,003 in a planchet containing 14,5 mg/cm 2 of residue. The counting efficiency for beta emitters ranged from 0,430 +- 0,036 for a weightless residue to 0,247 +- 0,020 in a planchet containing 17 mg/cm 2 of residue for 137 Cs standard. For 90 Sr/ 90 Y standard the efficiency ranged from 0,489 +- 0,041 for a weightless residue to 0,323 +- 0,026 in a planchet containing 18 mg/cm 2 of residue. Results make evident the counting efficiency variation with the alpha or beta emitters energies and the thickness of the water samples residue. So, the calibration standard, the thickness and the chemical composition of the residue must always be considered in the gross alpha and beta radioactivity determination in water samples. (author)

  1. Galex Lyman-alpha Emitters: Physical Properties, Luminosity Bimodality, And Morphologies.

    Science.gov (United States)

    Mallery, Ryan P.

    2010-01-01

    The Galaxy Evolution Explorer spectroscopic survey has uncovered a large statistically significant sample of Lyman-alpha emitters at z sim0.3. ACS imaging of these sources in the COSMOS and AEGIS deep fields reveals that these Lyman-alpha emitters consist of two distinct galaxy morphologies, face on spiral galaxies and compact starburst/merging systems. The morphology bimodality also results in a bimodal distribution of optical luminosity. A comparison between the UV photometry and MIPS 24 micron detections of these sources indicates that they are bluer, and have less dust extinction than similar star forming galaxies that lack Lyman-alpha detection. Our findings show how the global gas and dust distribution of star forming galaxies inhibits Lyman-alpha emission in star forming galaxies. GALEX is a NASA Small Explorer, launched in April 2003. We gratefully acknowledge NASA's support for construction, operation, and science analysis for the GALEX mission, developed in cooperation with the CNES of France and the Korean Ministry of Science and Technology.

  2. On the standardization of positron emitters by 4πγ counting

    International Nuclear Information System (INIS)

    Garcia-Torano, Eduardo; Peyres, Virginia; Roteta, Miguel

    2007-01-01

    This paper focuses on the application of the method known as ''4πγ counting'' to the standardization of positron emitters. Measurements and Monte Carlo simulations have been used to determine the optimal conditions of application. Two positron emitters ( 22 Na and 18 F) have been standardized, and the results are compared to those obtained by other methods. A good agreement has been found

  3. Alpha scintillation radon counting

    International Nuclear Information System (INIS)

    Lucas, H.F. Jr.

    1977-01-01

    Radon counting chambers which utilize the alpha-scintillation properties of silver activated zinc sulfide are simple to construct, have a high efficiency, and, with proper design, may be relatively insensitive to variations in the pressure or purity of the counter filling. Chambers which were constructed from glass, metal, or plastic in a wide variety of shapes and sizes were evaluated for the accuracy and the precision of the radon counting. The principles affecting the alpha-scintillation radon counting chamber design and an analytic system suitable for a large scale study of the 222 Rn and 226 Ra content of either air or other environmental samples are described. Particular note is taken of those factors which affect the accuracy and the precision of the method for monitoring radioactivity around uranium mines

  4. Prolixe-prototype reprocessing unit for irradiating wastes contamined with alpha emitters

    International Nuclear Information System (INIS)

    Madic, C.; Sontag, R.

    1987-01-01

    A large number of hot cells are employed for research on nuclear fuel reprocessing and the production of isotope of transuranium elements. These activities generate solid wastes highly contaminated with alpha, beta, gamma emitters. The Prolixe hot cell was built in order to: 1/ reprocess the solid wastes contaminated with alpha, beta, gamma emitters produced in the Radiochemistry building: 2/ produce package wastes storable in shallow-ground disposal sites: 3/ develop a process sufficiently flexible to make it applicable to waste produced in other installations. The process is based on waste leaching after grinding. Depending on the type of wastes the leaching reactant will have a different composition 1/ nitric acid solution for cellulose waste: 2/ nitric solutions containing Ag(II) for other material. The complete process should achieve: 1/ a high waste volume reduction factor: 2/ the production of immobilized waste packages storage in shallow-ground disposal sites: 3/ the recycling of transuranium elements: 4/ the generation of a minimal volume of effluents. This process can be considered as an alternative process to incineration for the reprocessing of solid wastes highly contaminated with alpha, beta, gamma emitters

  5. Beta/alpha continuous air monitor

    Science.gov (United States)

    Becker, G.K.; Martz, D.E.

    1988-06-27

    A single deep layer silicon detector in combination with a microcomputer, recording both alpha and beta activity and the energy of each pulse, distinquishing energy peaks using a novel curve fitting technique to reduce the natural alpha counts in the energy region where plutonium and other transuranic alpha emitters are present, and using a novel algorithm to strip out radon daughter contribution to actual beta counts. 7 figs.

  6. Alpha spectrometry of thick sources. I. Application to alpha emitters determination

    International Nuclear Information System (INIS)

    Acena, M.L.; Garcia-Torano, E.; Rivero, M.C.

    1977-01-01

    A method for determining alpha emitters by silicon surface barrier detector spectroscopy using thick sources is studied. Two types of spectra have been obtained. They have different shapes of line according to the procedure used for preparing the sources. For both spectra a computing least square programme has been developed. In this way it is possible to calculate line intensities with accuracy better than 20 percent. (author) [es

  7. Liquid scintillation alpha spectrometry techniques

    International Nuclear Information System (INIS)

    McKlveen, J.W.; McDowell, W.J.

    1984-01-01

    Accurate, quantitative determinations of alpha emitting nuclides by conventional plate counting methods are difficult, because of sample self-absorption problems in counting and because of non-reproducible losses in conventional sample separation methods. Liquid scintillation alpha spectrometry offers an attractive alternative with no sample self-absorption or geometry problems and with 100% counting efficiency. Sample preparation may include extraction of the alpha emitter of interest by a specific organic phase-soluble compound directly into the liquid scintillation counting medium. Detection electronics use energy and pulse-shape discrimination, to yield alpha spectra without beta and gamma background interference. Specific procedures have been developed for gross alpha, uranium, plutonium, thorium and colonium assay. Possibilities for a large number of other applications exist. Accuracy and reproducibility are typically in the 1% range. Backgrounds of the order of 0.01 cpm are readily achievable. The paper will present an overview of liquid scintillation alpha counting techniques and some of the results achieved for specific applications. (orig.)

  8. Application of avalanche photodiodes for the measurement of actinides by alpha liquid scintillation counting

    International Nuclear Information System (INIS)

    Reboli, A.

    2005-10-01

    Alpha emitters analysis using liquid scintillation spectroscopy is often used when sensitivity and fast samples preparation are the important points. A more extensive use of this technique is until now limited by its poor resolution compared to alpha particle spectroscopy with semiconductor detectors. To improve the resolution and thus promote this method for the measurement of actinides in environment, we have tested silicon avalanche photodiodes (APD) as new detectors for scintillation photons. The set-up consists of a large area avalanche photodiode (16 mm diameter) coupled to a thin vial containing alpha-emitters within a liquid scintillation cocktail. After optimization of several parameters like bias voltage, temperature, counting geometry and composition of the scintillating cocktail, energy resolutions have been found to be better than those obtained with standard photomultiplier tubes (PMT): 5% (200 keV FWHM) for 232 Th and 4.2% (240 keV FWHM) for 236 Pu. Our results show that the improvement is due to less fluctuations associated with light collection since the spatial response of APDs is more uniform than that of PMTs. The expected gain on quantum efficiency (80% for APDs instead of 25% for PMTs) is nullified by a corresponding increase on electronic noise and excess noise factor. Significant better results are foreseen by using green scintillators (450 - 550 nm wavelengths region) with larger Stokes-shift and blue-enhanced APDs which reach their maximum quantum efficiency in this region. (author)

  9. Alpha decay and nuclear deformation: the case for favoured alpha transitions of even-even emitters

    International Nuclear Information System (INIS)

    Garcia, F.; Goncalves, M.; Duarte, S.B.; Tavares, O.A.P.

    2000-02-01

    Alpha-decay half-life for ground-state transitions of 174 even-even alpha emitters has been calculated from a simple, Gamow-like model in which the quadrupole deformation of the product nucleus (assumed to have an ellipsoidal shape) is taken into account. The assumption made is that before tunneling through a purely Coulomb potential barrier the two-body system oscillates isotropically, thus giving rise to an equivalent, average polar direction θ (referred to the symmetry axis of the ellipsoid) for alpha emission. It is shown that the experimental half-life data are much better reproduced by the present description than in the spherical-shaped approximation for the daughter nucleus. (author)

  10. Alpha decay and nuclear deformation: the case for favoured alpha transitions of even-even emitters

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, F. [Universidade Estadual de Santa Cruz, Ilheus, BA (Brazil). Dept. de Ciencias Exatas e Tecnologicas; Rodriguez, O.; Guzman, F. [Instituto Superior de Ciencias y Tecnologia Nucleares (ISCTN), La Habana (Cuba); Goncalves, M. [Instituto de Radioprotecao e Dosimetria IRD/CNEN, Rio de Janeiro, RJ (Brazil); Duarte, S.B.; Tavares, O.A.P. [Centro Brasileiro de Pesquisas Fisicas (CBPF), Rio de Janeiro, RJ (Brazil). E-mail: sbd@cbpf.br

    2000-02-01

    Alpha-decay half-life for ground-state transitions of 174 even-even alpha emitters has been calculated from a simple, Gamow-like model in which the quadrupole deformation of the product nucleus (assumed to have an ellipsoidal shape) is taken into account. The assumption made is that before tunneling through a purely Coulomb potential barrier the two-body system oscillates isotropically, thus giving rise to an equivalent, average polar direction {theta} (referred to the symmetry axis of the ellipsoid) for alpha emission. It is shown that the experimental half-life data are much better reproduced by the present description than in the spherical-shaped approximation for the daughter nucleus. (author)

  11. Automatic spark counting of alpha-tracks in plastic foils

    International Nuclear Information System (INIS)

    Somogyi, G.; Medveczky, L.; Hunyadi, I.; Nyako, B.

    1976-01-01

    The possibility of alpha-track counting by jumping spark counter in cellulose acetate and polycarbonate nuclear track detectors was studied. A theoretical treatment is presented which predicts the optimum residual thickness of the etched foils in which completely through-etched tracks (i.e. holes) can be obtained for alpha-particles of various energies and angles of incidence. In agreement with the theoretical prediction it is shown that a successful spark counting of alpha-tracks can be performed even in polycarbonate foils. Some counting characteristics, such as counting efficiency vs particle energy at various etched foil thicknesses, surface spark density produced by electric breakdowns in unexposed foils vs foil thickness, etc. have been determined. Special attention was given to the spark counting of alpha-tracks entering thin detectors at right angle. The applicability of the spark counting technique is demonstrated in angular distribution measurements of the 27 Al(p,α 0 ) 24 Mg nuclear reaction at Ep = 1899 keV resonance energy. For this study 15 μm thick Makrofol-G foils and a jumping spark counter of improved construction were used. (orig.) [de

  12. NEBULAR ATTENUATION IN H{alpha}-SELECTED STAR-FORMING GALAXIES AT z = 0.8 FROM THE NewH{alpha} SURVEY

    Energy Technology Data Exchange (ETDEWEB)

    Momcheva, Ivelina G. [Astronomy Department, Yale University, New Haven, CT 06511 (United States); Lee, Janice C.; Ouchi, Masami [Carnegie Observatories, Pasadena, CA 91101 (United States); Ly, Chun [Space Telescope Science Institute, Baltimore, MD 21218 (United States); Salim, Samir [Astronomy Department, Indiana University, Bloomington, IN 47405 (United States); Dale, Daniel A. [Department of Physics and Astronomy, University of Wyoming, Laramie, WY 82071 (United States); Finn, Rose [Physics Department, Siena College, Loudonville, NY 12211 (United States); Ono, Yoshiaki, E-mail: ivelina.momcheva@yale.edu [Department of Astronomy, Graduate School of Science, University of Tokyo, Bunkyo-ku, Tokyo 113-0033 (Japan)

    2013-02-01

    We present measurements of the dust attenuation of H{alpha}-selected emission-line galaxies at z = 0.8 from the NewH{alpha} narrowband survey. The analysis is based on deep follow-up spectroscopy with Magellan/IMACS, which captures the strong rest-frame optical emission lines from [O II] {lambda}3727 to [O III] {lambda}5007. The spectroscopic sample used in this analysis consists of 341 confirmed H{alpha} emitters. We place constraints on the active galactic nucleus (AGN) fraction using diagnostics that can be applied at intermediate redshift. We find that at least 5% of the objects in our spectroscopic sample can be classified as AGNs and 2% are composite, i.e., powered by a combination of star formation and AGN activity. We measure the dust attenuation for individual objects from the ratios of the higher order Balmer lines. The H{beta} and H{gamma} pair of lines is detected with S/N > 5 in 55 individual objects and the H{beta} and H{delta} pair is detected in 50 individual objects. We also create stacked spectra to probe the attenuation in objects without individual detections. The median attenuation at H{alpha} based on the objects with individually detected lines is A(H{alpha}) = 0.9 {+-} 1.0 mag, in good agreement with the attenuation found in local samples of star-forming galaxies. We find that the z = 0.8 galaxies occupy a similar locus of attenuation as a function of magnitude, mass, and star formation rate (SFR) as a comparison sample drawn from the SDSS DR4. Both the results from the individual z = 0.8 galaxies and from the stacked spectra show consistency with the mass-attenuation and SFR-attenuation relations found in the local universe, indicating that these relations are also applicable at intermediate redshift.

  13. Determination of total alpha activity index in samples of radioactive wastes

    International Nuclear Information System (INIS)

    Galicia C, F. J.

    2015-01-01

    This study aimed to develop a methodology of preparation and quantification of samples containing radionuclides beta and/or alpha emitters, to determine the rates of alpha and beta total activity of radioactive waste samples. For this, a device of planchettes preparer was designed, to assist the planchettes preparation in a controlled environment and free of corrosive vapors. Planchettes were prepared in three means: nitrate, carbonate and sulfate, to different mass thickness, natural uranium (alpha and beta emitter) and in case of Sr-90 (beta emitter pure) only in half nitrate; and these planchettes were quantified in an alpha/beta counter, in order to construct the self-absorption curves for alpha and beta particles. These curves are necessary to determine the rate of alpha-beta activity of any sample because they provide the self-absorption correction factor to be applied in calculating the index. Samples with U were prepared with the help of the device of planchettes preparer and subsequently were analyzed in the proportional counter Mpc-100 Pic brand. Samples with Sr-90 were prepared without the device to see if there was a different behavior with respect to obtaining mass thickness. Similarly they were calcined and carried out count in the Mpc-100. To perform the count, first the parameters of counter operating were determined: operating voltages for alpha and beta particles 630 and 1500 V respectively, a count routine was generated where the time and count type were adjusted, and counting efficiencies for alpha and beta particles, with the aid of calibration sources of 210 Po for alphas and 90 Sr for betas. According to the results, the counts per minute will decrease as increasing the mass thickness of the sample (self-absorption curve), adjusting this behavior to an exponential function in all cases studied. The minor self-absorption of alpha and beta particles in the case of U was obtained in sulfate medium. The self-absorption curves of Sr-90 follow the

  14. Microdosimetry of monoclonal antibodies labeled with alpha emitters

    International Nuclear Information System (INIS)

    Fisher, D.R.

    1986-01-01

    The recent discovery of new techniques for the production of monoclonal antibodies (MoAB) has opened up a number of potential new applications in cancer diagnosis and therapy. Monoclonal antibodies labeled with alpha-emitting radionuclides promise to be particularly effective therapeutic agents due to the efficient cell killing ability of highly ionizing, short-range alpha particle tracks localized at specific antigen sites within the tumor mass. For a radioimmunotherapy treatment plan to be effective, one must be able to estimate the absorbed radiation dose to both tumor cells and normal tissues in the body. However, conventional methods used in nuclear medicine for estimating absorbed doses and specific absorbed fractions for radiopharmaceuticals do not apply to alpha emitters owing to their short range and the large variations in the local distribution of energy at the cellular level that result. Microdosimetric techniques developed for assessment of the radiological effects of internally deposited transuranic radionuclides take into account the statistical aspects of alpha particle track structure, energy distribution patterns, and radionuclide distribution within tissues, and provide a means for determining the number and frequency of cells irradiated, the probability densities in specific energy, and the average dose delivered to cells of interest. These techniques can be applied to the study of radiation absorbed dose from alpha-labeled monoclonal antibodies. 16 references, 6 figures

  15. Optimization in the nuclear fuel cycle II: Concentration of alpha emitters in the air

    International Nuclear Information System (INIS)

    Pereira, W.S.; Silva, A.X.; Lopes, J.M.; Carmo, A.S.; Mello, C.R.; Fernandes, T.S.; Kelecom, A.

    2017-01-01

    Optimization is one of the bases of radioprotection and aims to move doses away from the dose limit that is the borderline of acceptable radiological risk. The work aims to use the monitoring of the concentration of alpha emitters in the air as a tool of the optimization process. We analyzed 27 sampling points of airborne alpha concentration in a nuclear fuel cycle facility. The monthly averages were considered statistically different, the highest in the month of February and the lowest in the month of August. All other months were found to have identical mean activity concentration values. Regarding the sampling points, the points with the highest averages were points 12, 15 and 9. These points were indicated for the beginning of the optimization process. Analysis of the production of the facility should be performed to verify possible correlations between production and concentration of alpha emitters in the air

  16. AVERAGE METALLICITY AND STAR FORMATION RATE OF Ly{alpha} EMITTERS PROBED BY A TRIPLE NARROWBAND SURVEY

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, Kimihiko; Shimasaku, Kazuhiro; Ono, Yoshiaki; Okamura, Sadanori [Department of Astronomy, Graduate School of Science, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Ouchi, Masami [Institute for the Physics and Mathematics of the Universe (IPMU), TODIAS, The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8583 (Japan); Lee, Janice C.; Ly, Chun [Observatories of the Carnegie Institution of Washington, 813 Santa Barbara Street, Pasadena, CA 91101 (United States); Foucaud, Sebastien [Department of Earth Sciences, National Taiwan Normal University, No. 88, Tingzhou Road, Sec. 4, Taipei 11677, Taiwan (China); Dale, Daniel A. [Department of Physics and Astronomy, University of Wyoming, Laramie, WY (United States); Salim, Samir [Department of Astronomy, Indiana University, Bloomington, IN (United States); Finn, Rose [Department of Physics, Siena College, Loudonville, NY (United States); Almaini, Omar, E-mail: nakajima@astron.s.u-tokyo.ac.jp [School of Physics and Astronomy, University of Nottingham, Nottingham (United Kingdom)

    2012-01-20

    We present the average metallicity and star formation rate (SFR) of Ly{alpha} emitters (LAEs) measured from our large-area survey with three narrowband (NB) filters covering the Ly{alpha}, [O II]{lambda}3727, and H{alpha}+[N II] lines of LAEs at z = 2.2. We select 919 z = 2.2 LAEs from Subaru/Suprime-Cam NB data in conjunction with Magellan/IMACS spectroscopy. Of these LAEs, 561 and 105 are observed with KPNO/NEWFIRM near-infrared NB filters whose central wavelengths are matched to redshifted [O II] and H{alpha} nebular lines, respectively. By stacking the near-infrared images of the LAEs, we successfully obtain average nebular-line fluxes of LAEs, the majority of which are too faint to be identified individually by NB imaging or deep spectroscopy. The stacked object has an H{alpha} luminosity of 1.7 Multiplication-Sign 10{sup 42} erg s{sup -1} corresponding to an SFR of 14 M{sub Sun} yr{sup -1}. We place, for the first time, a firm lower limit to the average metallicity of LAEs of Z {approx}> 0.09 Z{sub Sun} (2{sigma}) based on the [O II]/(H{alpha}+[N II]) index together with photoionization models and empirical relations. This lower limit of metallicity rules out the hypothesis that LAEs, so far observed at z {approx} 2, are extremely metal-poor (Z < 2 Multiplication-Sign 10{sup -2} Z{sub Sun }) galaxies at the 4{sigma} level. This limit is higher than a simple extrapolation of the observed mass-metallicity relation of z {approx} 2 UV-selected galaxies toward lower masses (5 Multiplication-Sign 10{sup 8} M{sub Sun }), but roughly consistent with a recently proposed fundamental mass-metallicity relation when the LAEs' relatively low SFR is taken into account. The H{alpha} and Ly{alpha} luminosities of our NB-selected LAEs indicate that the escape fraction of Ly{alpha} photons is {approx}12%-30%, much higher than the values derived for other galaxy populations at z {approx} 2.

  17. Measurement of Alpha Emitters Concentration in Imported Cigarettes

    International Nuclear Information System (INIS)

    Nasser Allah, Z.K.; Musa, W.A.; AL-Rawi, A.A.S.

    2011-01-01

    The aime of this study was to measured the alpha emitters concentration of (15) different kinds of imported cigarettes. the nuclear reaction used U-235(n, f) obtained by the bombardment of U-235 with thermal neutrons from (Am B e)neutron source with thermal flux of(5*10 3 n.cm -2 .s -1 ). The Results obtained showed the values of the Uranium concentration, and varies from (0.041 ppm) in five stares kind to (2.374ppm) in Machbeth (chocolate) 100's kind. All the result obtained are within the limit levels as given by UNSCAR data

  18. Study of electrodeposition technique to prepare alpha-counting plates of uranium 233

    International Nuclear Information System (INIS)

    Mertzig, W.

    1979-01-01

    The electrodeposition technique to prepare alpha-counting plates of 233 U for its determination is presented. To determine the optimum conditions for plating 233 U the effects of such parameters as current density, pH of eletrotype, salt concentration, time of electrolysis and distance electrodes were studied. A carrier method was developed to attain a quantitative electrodeposition of 233 U from aqueous solutions into alpha counting paltes. A single and incremental addition of natural uranium and thorium as carrier were studied. All samples were prepared using a electrodeposition cell manufactured at the IPEN, especially for use in electroplating tracer actinides. This cell is made of a metal-lucite to contain the electrolyte, which bottom is a polished brass disk coated with a Ni film serving as the cathode. A Pt wire anode is fixed on the top of the cell. The electroplated samples were alpha-counted using a surface barrier detector. A recovery of more than 99% was obtained in specific conditions. The plating procedure produced deposits which were firmly distributed over the plate area. The method was applied to determine tracer amounts of 233 U from oxalate and nitrate solutions coming from chemical processing irradiated thorium. (Author) [pt

  19. Application of PSD for low level alpha counting using liquid scintillation counting

    International Nuclear Information System (INIS)

    Krishnamachari, G.; Vaze, P.K.; Iyer, M.R.

    1989-01-01

    In the liquid scintillator the light produced by alpha particles decays differently than those produced by electrons. Pulse shape discrimination (PSD) methods are employed to estimate low levels of alpha emitting radionuclides by reducing the background due to either beta or gamma events. An attempt is being made to develop a liquid scintillation counting sytem using a simple PSD circuit to achieve a background of 0.01 counts/min. The PSD circuit is based on measuring zero cross over points to differentiate particle types. The input signal is first differentiated by a delay line and subsequently by a RC circuit. The width of the initial part of the doubly differentiated pulse is different for alpha and beta pulses. This width is converted to amplitude by a time-to-amplitude converter (TAC). The higher amplitude pulses from the TAC are due to alpha particles and they are separated by an integral discriminator. The output from the integral discriminator opens a linear gate to record the pulse height spectrum. The figure of merit of the PSD circuit and background in the alpha energy channel have been worked out using different scintillator types. (author). 4 figs

  20. Determination of radium-226 in fresh water, using alpha spectroscopy

    International Nuclear Information System (INIS)

    Byrakdar, M. E.

    2006-12-01

    Four radium isotopes are present in nature, i.e. Ra-223, Ra-224, Ra-226, and Ra-228. The first three are alpha emitters while the last is a beta emitter. Because of the importance of the determination of Alpha isotope emitters in pure water (drinking water), this work focuses on the determination of radium-226 as it has the longest half-life (1600 years, in comparison to 11.4 day, 3.66 days for Ra-223 and Ra-224, respectively) using Alpha spectroscopy. This method has the capability to be applied in sampling fields and low detection limit which in turn makes the analysis of low-level radioactive environmental water samples, with hardness does not exceed 40 French Degree, satisfying for health and environment control programmes. However, counting the samples using Alpha spectroscopy has to be immediate (or within 48 hours). (author)

  1. Alpha particle analysis using PEARLS spectrometry

    International Nuclear Information System (INIS)

    McKlveen, J.W.; Klingler, G.W.; McDowell, W.J.; Case, G.N.

    1984-01-01

    Alpha particle assay by conventional plate-counting methods is difficult because chemical separation, tracer techniques, and/or self-absorption losses in the final sample may cause either non-reproducible results or create unacceptable errors. PEARLS (Photon-Electron Rejecting Alpha Liquid Scintillation) Spectrometry is an attractive alternative since radionuclides may be extracted into a scintillator in which there would be no self-absorption or geometry problems and in which up to 100% chemical recovery and counting efficiency is possible. Sample preparation may include extraction of the alpha emitter of interest by a specific organic-phase-soluble compound directly into the liquid scintillator. Detection electronics use energy and pulse-shape discrimination to provide discrete alpha spectra and virtual absence of beta and gamma backgrounds. Backgrounds on the order of 0.01 cpm are readily achievable. Accuracy and reproducibility are typically in the 100 +-1% range. Specific procedures have been developed for gross alpha, uranium, plutonium, thorium, and polonium assay. This paper will review liquid scintillation alpha counting methods and reference some of the specific applications. 8 refs., 1 fig

  2. Therapy with high LET Radioisotopes: Can sufficient levels of attractive Auger and alpha emitters be produced to make their use practical?

    International Nuclear Information System (INIS)

    Knapp, F.F. Jr.; Mirzadeh, S.; Stabin, M.; Brill, A.B.

    2005-01-01

    Because of localized energy deposition within a very small volume, cellular targeted therapy with high linear energy transfer (LET) Auger-electron and alpha-particle emitting radioisotopes is of great interest. While the energy deposition from alpha particles usually encompasses several cell diameters, the dose from Auger electrons is confined to a single cell. Two major challenges for broader use of Alpha and Auger emitters are the efficient and cost effective routine production of sufficient levels of these radioisotopes, and the availability of targeting molecules to which the radioisotopes can be attached for cellular delivery of sufficient levels of activity for effective therapy. Examples of several Alpha-and Auger-emitting radioisotopes of current interest are presented. Alpha- and Auger electron-emitting radioisotopes can be produced in accelerators (A) and nuclear reactors (R), and several alpha emitter congeners (i.e. thorium-229) can be obtained from uranium decay products. The challenge for reactor production, is the availability and exploitation of methods - other then the usual radiative (n,γ) production route which will provide no-carrier-added (nca) or the high specific activity radioisotopes of interest. The submitted manuscript has been authored by a contractor of the U.S. Government under contract DE-AC05-00OR22725. Accordingly, the U.S. Government retains a nonexclusive, royalty-free license to publish or reproduce the published form of this contribution, or allow others to do so, for U.S. Government purposes High LET radioisotopes of current interest which are in the initial stages of development and/or which demonstrate practical use in clinical trials include several alpha-emitters, in particular bismuth-213 - and also the actinium-225 parent - astatine-211 and bismuth-212. Extensive experimental studies have been reported with Auger iododeoxyuridine (IdUR) radiolabeled with the iodine-125 emitter-labeled. However, development of production

  3. Determination of substraces of alpha emitter elements in water

    International Nuclear Information System (INIS)

    Gascon, J.L.

    1990-01-01

    To determine alpha emitter elements in water by alpha spectrometry, it is necessary to use large volumes of samples, concentration techniq-ues and to separate the elements of interest. In this report a study is presented about two concentration techniques and the process of analysis. Firstly, the stages of concentration method by iron hydroxide coprecipitation were studied in order to improve the results. The combination of liquid-liquid extraction and ion exchange techniques was the best way. Secondly, the technique by adsorption on manganese dioxide was studied. To apply this technique it was necessary to develop analysis methods to separate uranium, thorium, plutonium, americium and radium. These methods were designed combining several techniques of separation: liquid-liquid extraction, liquid-solid extraction, ionic exchange and coprecipitation. After the analysis methods were developped the adsorption on manganese dioxide with artificial samples was studied in the laboratory. Finally, the method of adsorption on manganese dioxide was studied to determine uranium, thorium and radium in the drinking water of Madrid. (Author)

  4. Development of methodology for detection of long lived alpha emitters in air based on simultaneous alpha and beta activity measurement

    International Nuclear Information System (INIS)

    Kaushik, Vivek; Rath, D.P.; Vinayagami, Bhakti; Ashokkumar, P.; Umashankar, C.; Gopalakrishnan, R.K.; Kulkarni, M.S.

    2018-01-01

    Interference of the radon and thoron progeny co-deposited on the filtration media is the long-standing problem related to prompt analyses in continuous air sampling or monitoring of any potential suspect radionuclides. The solutions to this problem have been quite diverse, and included, for example, simple gross-alpha counting, the use of beta-to-alpha ratios, and the use of alpha spectrum analyses. The techniques based on beta to alpha disintegration ratios make use of the naturally occurring alpha to beta disintegration ratios and departures therefrom. This ratio is found empirically to be relatively constant. With the help of the solution of differential equation, which govern the deposition of radionuclide on filter paper, one can easily estimate theoretically the behavior of the radon progeny alpha to beta disintegration (or count) rate ratio

  5. Fabrication, characterization and simulation of 4H-SiC Schottky diode alpha particle detectors for pyroprocessing actinide monitoring

    Science.gov (United States)

    Garcia, Timothy Richard

    Pyroprocessing is a method of using high-temperature molten salts and electric fields to separate and collect fuel isotopes of used nuclear fuel. It has been has been tested in the U.S. at Idaho National Laboratory as a key step in closing the nuclear fuel cycle. One technical problem with the pyroprocessing method is a lack of knowledge regarding the actinide concentrations in the salt bath during operation, since on-line techniques for measuring these concentrations are not presently available. 4H-SiC Schottky diode detectors can potentially fulfill this need. Such detectors would operate in contact with the molten salt, and measure concentrations via alpha-particle spectroscopy. This work seeks to fabricate and characterize 4H-SiC Schottky diode detectors at high temperature, model the alpha particle spectrum expected in a molten salt, and model the operation of the detectors to confirm the physics of operation is as expected. In this work, 4H-SiC Schottky diode detectors were fabricated at OSU Nanotech West. After fabrication, these detectors were characterized using both I-V curves and Am-241 alpha-particle energy spectra. All measurements were made as a function of temperature, from room temperature up to 500°C. The average energy required to create an electron-hole pair was observed to decrease with an increase of temperature, due to a decrease of both the 4H-SiC bandgap and non-linear energy loss terms. Furthermore, the FWHM of the spectra was observed to be dependent on the leakage current at a certain temperature, and not dependent on the temperature itself. Secondly, the alpha particle energy spectrum in the pyroprocessing environment was modeled using SRIM. The molten salt was modeled in 3 different geometries, with or without a protective cover material on top of the detector. Due to the loss of alpha-particle energy in the molten salt itself, a high-energy alpha emitter may completely cover the spectrum from a lower-energy alpha emitter. Each of the

  6. Some applications of Photon/Electron-Rejecting Alpha Liquid Scintillation (PERALS) spectrometry to the assay of alpha emitters

    International Nuclear Information System (INIS)

    McDowell, W.J.; Case, G.N.

    1988-01-01

    The combination of certain solvent extraction separations and a special kind of liquid scintillation detector and electronics designed for alpha spectrometry allows some highly accurate, yet simple determinations of alpha-emitting nuclides. Counting efficiency is 99.68% with backgrounds of 99.95%. The Photon/Electron Rejecting Alpha Liquid Scintillation (PERALS) equipment is described and procedures for the separation and determination of uranium, thorium, plutonium, polonium, radium, and trivalent actinides are outlined. 25 refs., 10 figs., 1 tab

  7. Irradiation of bone lining cells from bone-seeking alpha-emitters

    International Nuclear Information System (INIS)

    Kruglikov, I.; Polig, E.

    1993-01-01

    The influence of bone remodeling and the non-uniform distribution of alpha-emitters on the hit statistics is discussed. It is shown that for the first generation of bone lining cells, bone remodeling decreases the probability of no hits to the nuclei of these cells whereas the randomness of the spatial distribution of nuclide increases this probability. For the subsequent generations bone remodeling as well as spatial distribution of nuclide increase the probability of no hits. The most conservative estimations for the variance of hits and probability of no hits, which are defined by the minimums of these values, are obtained. (orig.)

  8. Gross alpha/beta analyses in water by liquid scintillation counting

    International Nuclear Information System (INIS)

    Wong, C.T.; Lawrence Livermore National Laboratory, CA; Soliman, V.M.; Perera, S.K.

    2005-01-01

    The standard procedure for analyzing gross alpha and gross beta in water is evaporation of the sample and radioactivity determination of the resultant solids by proportional counting. This technique lacks precision, and lacks sensitivity for samples with high total dissolved solids. Additionally, the analytical results are dependent on the choice of radionuclide calibration standard and the sample matrix. Direct analysis by liquid scintillation counting has the advantages of high counting efficiencies and minimal sample preparation time. However, due to the small sample aliquants used for analysis, long count times are necessary to reach required detection limits. The procedure proposed consists of evaporating a sample aliquant to dryness, dissolving the resultant solids in a small volume of dilute acid, followed by liquid scintillation counting to determine radioactivity. This procedure can handle sample aliquants containing up to 500 mg of dissolved solids. Various acids, scintillation cocktail mixtures, instrument discriminator settings, and regions of interest (ROI) were evaluated to determine optimum counting conditions. Precision is improved and matrix effects are reduced as compared to proportional counting. Tests indicate that this is a viable alternative to proportional counting for gross alpha and gross beta analyses of water samples. (author)

  9. Determination of total alpha activity index in samples of radioactive wastes; Determinacion del indice de actividad alfa total en muestras de desechos radiactivos

    Energy Technology Data Exchange (ETDEWEB)

    Galicia C, F. J.

    2015-07-01

    This study aimed to develop a methodology of preparation and quantification of samples containing radionuclides beta and/or alpha emitters, to determine the rates of alpha and beta total activity of radioactive waste samples. For this, a device of planchettes preparer was designed, to assist the planchettes preparation in a controlled environment and free of corrosive vapors. Planchettes were prepared in three means: nitrate, carbonate and sulfate, to different mass thickness, natural uranium (alpha and beta emitter) and in case of Sr-90 (beta emitter pure) only in half nitrate; and these planchettes were quantified in an alpha/beta counter, in order to construct the self-absorption curves for alpha and beta particles. These curves are necessary to determine the rate of alpha-beta activity of any sample because they provide the self-absorption correction factor to be applied in calculating the index. Samples with U were prepared with the help of the device of planchettes preparer and subsequently were analyzed in the proportional counter Mpc-100 Pic brand. Samples with Sr-90 were prepared without the device to see if there was a different behavior with respect to obtaining mass thickness. Similarly they were calcined and carried out count in the Mpc-100. To perform the count, first the parameters of counter operating were determined: operating voltages for alpha and beta particles 630 and 1500 V respectively, a count routine was generated where the time and count type were adjusted, and counting efficiencies for alpha and beta particles, with the aid of calibration sources of {sup 210}Po for alphas and {sup 90}Sr for betas. According to the results, the counts per minute will decrease as increasing the mass thickness of the sample (self-absorption curve), adjusting this behavior to an exponential function in all cases studied. The minor self-absorption of alpha and beta particles in the case of U was obtained in sulfate medium. The self-absorption curves of Sr-90

  10. Simple emittance measurement of H- beams from a large plasma source

    International Nuclear Information System (INIS)

    Guharay, S.K.; Tsumori, K.; Hamabe, M.; Takeiri, Y.; Kaneko, O.; Kuroda, T.

    1996-03-01

    An emittance meter is developed using pepper-pot method. Kapton foils are used to detect intensity distributions of small beamlets at the 'image' plane of the pepper-pot. Emittance of H - beams from a large plasma source for the neutral beam injector of the Large Helical Device (LHD) has been measured. The normalized emittance (95%) of a 6 mA H - beam with emission current density of about 10 mA/cm 2 is ∼0.59 mm mrad. The present system is very simple, and it eliminates many complexities of the existing schemes. (author)

  11. A manual low background alpha beta counting system

    Energy Technology Data Exchange (ETDEWEB)

    Levison, S; German, U; Peled, O; Turgeman, S; Vangrovitz, U; Tirosh, D; Piestum, S; Assido, H [Israel Atomic Energy Commission, Beersheba (Israel). Nuclear Research Center-Negev

    1996-12-01

    An Alpha and Beta counting system consisting of a micro controller-based electronic unit and detectors assembly was developed. The radiation detection unit consists of two proportional detectors (a main detector and a cosmic-ray guard detector) which can be easily disassembled for decontamination or repair. The detectors are mounted in a manual operating sample changer shielded by 5 cm of lead. Simplicity of maintenance and functional operation were taken into consideration in the design. The electronic unit supplies the high voltage and enables the operational functions including controls anti alarms. Calculations of net cpm of Alpha and Beta counting are displayed and can be printed. RS-232 communication option enables connection to a computer and operation of more sophisticated programs for calculations and data storage in the future (authors).

  12. A manual low background alpha beta counting system

    International Nuclear Information System (INIS)

    Levison, S.; German, U.; Peled, O.; Turgeman, S.; Vangrovitz, U.; Tirosh, D.; Piestum, S.; Assido, H.

    1996-01-01

    An Alpha and Beta counting system consisting of a micro controller-based electronic unit and detectors assembly was developed. The radiation detection unit consists of two proportional detectors (a main detector and a cosmic-ray guard detector) which can be easily disassembled for decontamination or repair. The detectors are mounted in a manual operating sample changer shielded by 5 cm of lead. Simplicity of maintenance and functional operation were taken into consideration in the design. The electronic unit supplies the high voltage and enables the operational functions including controls anti alarms. Calculations of net cpm of Alpha and Beta counting are displayed and can be printed. RS-232 communication option enables connection to a computer and operation of more sophisticated programs for calculations and data storage in the future (authors)

  13. Calibration of a liquid scintillation counter for alpha, beta and Cerenkov counting

    International Nuclear Information System (INIS)

    Scarpitta, S.C.; Fisenne, I.M.

    1996-07-01

    Calibration data are presented for 25 radionuclides that were individually measured in a Packard Tri-Carb 2250CA liquid scintillation (LS) counter by both conventional and Cerenkov detection techniques. The relationships and regression data between the quench indicating parameters and the LS counting efficiencies were determined using microliter amounts of tracer added to low 40 K borosilicate glass vials containing 15 mL of Insta-Gel XF scintillation cocktail. Using 40 K, the detection efficiencies were linear over a three order of magnitude range (10 - 10,000 mBq) in beta activity for both LS and Cerenkov counting. The Cerenkov counting efficiency (CCE) increased linearly (42% per MeV) from 0.30 to 2.0 MeV, whereas the LS efficiency was >90% for betas with energy in excess of 0.30 MeV. The CCE was 20 - 50% less than the LS counting efficiency for beta particles with maximum energies in excess of 1 MeV. Based on replicate background measurements, the lower limit of detection (LLD) for a 1-h count at the 95% confidence level, using water as a solvent, was 0.024 counts sec- -1 and 0.028 counts sec-1 for plastic and glass vials, respectively. The LLD for a 1-h-count ranged from 46 to 56 mBq (2.8 - 3.4 dpm) for both Cerenkov and conventional LS counting. This assumes: (1) a 100% counting efficiency, (2) a 50% yield of the nuclide of interest, (3) a 1-h measurement time using low background plastic vials, and (4) a 0-50 keV region of interest. The LLD is reduced an order of magnitude when the yield recovery exceeds 90% and a lower background region is used (i.e., 100 - 500 keV alpha region of interest). Examples and applications of both Cerenkov and LS counting techniques are given in the text and appendices

  14. Measurement of radionuclides using ion chromatography and flow-cell scintillation counting with pulse shape discrimination

    International Nuclear Information System (INIS)

    DeVol, T.A.; Fjeld, R.A.

    1995-01-01

    A project has been initiated at Clemson Univ. to develop a HPLC/flow- cell system for analysis of non-gamma emitting radionuclides in environmental samples; an important component is development of a low background flow-cell detector that counts alpha and beta particles separately through pulse shape discrimination. Objective of the work presented here is to provide preliminary results of an evaluation of the following scintillators: CaF 2 :Eu, scintillating glass, and BaF 2 . Slightly acidic aqueous solutions of the alpha emitter 233 U and the beta emitter 45 Ca were used. Detection efficiencies and minimum detectable activities were determined

  15. Immuno-vectorization of radioelements emitters of alpha particles: a new therapy in cancerology

    International Nuclear Information System (INIS)

    Bourgeois, M.

    2007-05-01

    The radio-immunotherapy is an anti cancerous therapy which consists in vectorising with immuno-specific agents very radio toxic radioelements on tumors or in their environment to destroy them. The first part of this report presents the different characteristics of antibodies as well as their means of production under monoclonal shapes specifically steered against a tumoral antigen of interest. The second part of this report replaces the importance of the immunological vectors in the context of the nuclear medicine. It is notably described that the different methods which allow to radio-label the vector, as well as the different ways of optimization which were envisaged to improve the targeting of radioelements on a tumor. These different developments allow to define the potential place of the alpha radio-immunotherapy in treatments and so re-place the interest of the experimental part. If the radio-immunotherapy, using beta emitters isotopes as the 131 iodine or the 90 yttrium, is today current in anti cancerous therapy, it finds limits because of the disintegration characteristics of the isotopes it uses. Indeed, compared with alpha particles, the beta particles deposit less energy by unit of length in the crossed material.The experimental part of this report aims at studying the feasibility of the coupling between an immunological vector and an alpha emitter isotope.The different tests led on the bismuth 213, the bismuth 212, the lead 212 and the astatine 211 demonstrated that the fixation of these radionuclides was possible. This research theme is strengthened by the construction in Nantes of a cyclotron with high energy ( A.R.R.O.N.A.X.) and the optimization of the obtained promising results should allow a therapeutic use in oncology of the alpha radio-immunotherapy. (N.C.)

  16. Increased microerythrocyte count in homozygous alpha(+-thalassaemia contributes to protection against severe malarial anaemia.

    Directory of Open Access Journals (Sweden)

    Freya J I Fowkes

    2008-03-01

    Full Text Available The heritable haemoglobinopathy alpha(+-thalassaemia is caused by the reduced synthesis of alpha-globin chains that form part of normal adult haemoglobin (Hb. Individuals homozygous for alpha(+-thalassaemia have microcytosis and an increased erythrocyte count. Alpha(+-thalassaemia homozygosity confers considerable protection against severe malaria, including severe malarial anaemia (SMA (Hb concentration 1.1 x 10(12/l as a result of the reduced mean cell Hb in homozygous alpha(+-thalassaemia. In addition, children homozygous for alpha(+-thalassaemia require a 10% greater reduction in erythrocyte count than children of normal genotype (p = 0.02 for Hb concentration to fall to 50 g/l, the cutoff for SMA. We estimated that the haematological profile in children homozygous for alpha(+-thalassaemia reduces the risk of SMA during acute malaria compared to children of normal genotype (relative risk 0.52; 95% confidence interval [CI] 0.24-1.12, p = 0.09.The increased erythrocyte count and microcytosis in children homozygous for alpha(+-thalassaemia may contribute substantially to their protection against SMA. A lower concentration of Hb per erythrocyte and a larger population of erythrocytes may be a biologically advantageous strategy against the significant reduction in erythrocyte count that occurs during acute infection with the malaria parasite Plasmodium falciparum. This haematological profile may reduce the risk of anaemia by other Plasmodium species, as well as other causes of anaemia. Other host polymorphisms that induce an increased erythrocyte count and microcytosis may confer a similar advantage.

  17. Negative ion emission at field electron emission from amorphous (alpha-C:H) carbon

    CERN Document Server

    Bernatskij, D P; Ivanov-Omskij, V I; Pavlov, V G; Zvonareva, T K

    2001-01-01

    The study on the electrons field emission from the plane cathode surface on the basis of the amorphous carbon film (alpha-C:H) is carried out. The methodology, making it possible to accomplish simultaneously the registration of the emission currents and visually observe the distribution of the emission centers on the plane emitter surface is developed. The analysis of the oscillograms indicated that apart from the proper electron constituent the negative ions of hydrogen (H sup - and H sub 2 sup -), carbon (C sup -) and hydrocarbon (CH sub n sup -) are observed. The ions emission is connected with the processes of formation and degradation of the local emission centers

  18. Spark counting technique of alpha tracks on an aluminium oxide film

    International Nuclear Information System (INIS)

    Morishima, Hiroshige; Koga, Taeko; Niwa, Takeo; Kawai, Hiroshi

    1984-01-01

    We have tried to use aluminium oxide film as a neutron detector film with a spark counter for neutron monitoring in the mixed field of neutron and gamma-rays near a reactor. The merits of this method are that (1) aluminium oxide is good electric insulator, (2) any desired thickness of the film can be prepared, (3) chemical etching of the thin film can be dispensed with. The relation between spark counts and numbers of alpha-particles which entered the aluminium oxide film 1 μm thick was linear in the range of 10 5 -10 7 alpha-particles. The sensitivity(ratio of the spark counts to irradiated numbers of alpha-particles) was approximately 10 -3 . (author)

  19. Alpha particle emitters in cancer therapy: establishing the rationale and overcoming the difficulties

    International Nuclear Information System (INIS)

    Sgouros, G.

    1996-01-01

    rapidly accessible disease. Alpha particles will be most useful in situations in which targeting is rapid, killing of isolated single-cells is important and access to normal tissue is minimized. The latter may be achieved by intracavitary administration or by labeling an agent that does not reach normal tissues before the radionuclide has decayed below an acceptable level. Although alpha-particle emitters have shown promise in animal models, they have not been examined in patients. The decay of 212 Bi is accompanied by emission of high energy (2.6 MeV) photons which are difficult to shield; 211 At is cyclotron produced and of limited availability. The initial obstacles to the use of alpha-particle emitters for therapy are availability, handling and radiochemistry. These are being overcome with the introduction of new radionuclides and better radiochemistry. Bismuth-213, for example, is similar to Bi-212 in its alpha particle emissions but does not emit the highly energetic photon seen with Bi-212. Once the initial, logistical obstacles are surmounted, the dosimetry and normal tissue toxicity must be investigated

  20. Localization of alpha emitters by damage production in a thin film. Application to the study of alpha emitter diffusion in irradiated samples; Localisation des emetteurs alpha par creation de dommages dans un film mince. Application a l'etude de la diffusion des emetteurs alpha dans des echantillons irradies

    Energy Technology Data Exchange (ETDEWEB)

    Houdaille, B; Perrot, M [Commissariat a l' Energie Atomique, 91 - Saclay (France). Centre d' Etudes Nucleaires

    1968-07-01

    The process of recording {alpha} particles on cellulose nitrate films, called alpha-graphy, is applied to the study of the diffusion of {alpha}-emitting elements in irradiated alloys. The existence of diffusion is shown by attacking the film with concentrated caustic soda after exposition. The insensitivity of the recorder to {beta} {gamma} radiation emitted by the sample after passing in the reactor makes it possible to operate with long exposure times and to detect small diffusions. The concentration-penetration curves are drawn up after carrying out a densitometric analysis of the alpha-graphies. - As the cellulose nitrate is affected only by {alpha} particles of energies of between 0.5 and 4 MeV, it was first necessary to determine the yield of the recorder for {alpha} particles emitted by a thick source, i.e. whose energy varies between 0 and E{sub 0}, E{sub 0} being the energy of the alpha emitter. - The concentration C of the {alpha}-emitter, as a function of the optical density D of the alpha-graphy, and of the exposure time t is given by a simple relationship: C = D/at where a is an experimental constant determined by calibration. It depends on the nature of the cellulose nitrate, of the {alpha}-emitting element and of the alloy studied. (authors) [French] Le procede d'enregistrement des particules alpha sur film de nitrate de cellulose, ou alphagraphie, est applique a l'etude de la diffusion d'elements emetteurs alpha dans des alliages irradies. La diffusion est mise en evidence par une attaque du film de nitrate, apres exposition, dans de la soude concentree. L'insensibilite de l'enregistreur au rayonnement {beta} {gamma}, emis par l'echantillon apres son sejour en pile, permet d'operer sur de longs temps de pose et de detecter des diffusions faibles. Les courbes concentration - penetration sont etablies par exploitation densitometrique des alphagraphies. - Comme le nitrate de cellulose n'est impressionne que par des particules alpha dont l'energie est

  1. An analytical model to calculate absorbed fractions for internal dosimetry with alpha, beta and gamma emitters

    Directory of Open Access Journals (Sweden)

    Ernesto Amato

    2014-03-01

    Full Text Available We developed a general model for the calculation of absorbed fractions in ellipsoidal volumes of soft tissue uniformly filled with alpha, beta and gamma emitting radionuclides. The approach exploited Monte Carlo simulations with the Geant4 code to determine absorbed fractions in ellipsoids characterized by a wide range of dimensions and ellipticities, for monoenergetic emissions of each radiation type. The so-obtained absorbed fractions were put in an analytical relationship with the 'generalized radius', calculated as 3V/S, where V is the ellipsoid volume and S its surface. Radiation-specific parametric functions were obtained in order to calculate the absorbed fraction of a given radiation in a generic ellipsoidal volume. The dose from a generic radionuclide can be calculated through a process of summation and integration over the whole radionuclide emission spectrum, profitably implemented in an electronic spreadsheet. We compared the results of our analytical calculation approach with those obtained from the OLINDA/EXM computer software, finding a good agreement in a wide range of sphere radii, for the high-energy pure beta emitter 90Y, the commonly employed beta-gamma emitter 131I, and the pure alpha emitter 213Po. The generality of our approach makes it useful an easy to implement in clinical dosimetry calculations as well as in radiation safety estimations when doses from internal radionuclide uptake are to be taken into account.

  2. Spectrum library concept and pulse shape analysis in liquid scintillation counting

    Energy Technology Data Exchange (ETDEWEB)

    Kaihola, L [Wallac Oy, Turku (Finland)

    1997-03-01

    Wallac introduced in 1990 a new absolute liquid scintillation counting (LSC) method, Digital Overlay Technique (DOT) to correct for quench. This method allows quantization of multilabel samples by referring to library spectra which are generated against chemical and color quench indices at the factory. The libraries can further be expanded to any beta emitter by user with a method called fine tuning, which can be carried out even with a single sample. Spectrum libraries are created over the whole spectrum range of the radionuclide and allow automatic identification of a single label beta emitting radionuclide, called Easy Count method. Another improvement in LSC is commercial introduction of Pulse Shape Analysis (PSA) in 1986 by Wallac. This method recognizes alpha particle decay by pulse shape and leads to excellent sensitivity in alpha counting because most of the background signal in LSC comprises of short or beta like pulses. PSA detects alpha events in the presence of high excess of beta activity over alphas, up to a ratio 100000 to 1. (orig.)

  3. Characterization Of The Alpha/Beta Counting System Type MPC 9400 And Its Utilization

    International Nuclear Information System (INIS)

    Makhsum; Sutarman; Fikri, Hanif; Handoko, Djati

    2000-01-01

    Have been carried out the experiment to determine the operation voltage, instrument stability, counting efficiency, figure of merit, and minimum detectable activity. This instrument used to count gross alpha and gross beta. This instrument belongs good stability at the confidence level of 95 % and the background count that was 0,144 cpm for alpha and 22,65 cpm for beta. The counting efficiency was 27,41 % (electrodeposition of Am-241), 6,57 % (deposition of Am-241), 51,82 % (deposition of Sr-90). The limit of detectable activity was 1,04 x 10 exp.-2 Bq (electrodeposition of Am-241), 4,35 x 10 exp.-2 Bq (% deposition of Sr 90)

  4. Phoswich Detector for Simultaneous Counting of Alpha- and Beta-ray in a Pipe during Decommissioning

    International Nuclear Information System (INIS)

    Seo, B.K.; Kim, G.H.; Woo, Z.H.; Jung, Y.H.; Oh, W.Z.; Lee, K.W.; Han, M.J.

    2006-01-01

    A great quantity of waste has been generated during the decommissioning of nuclear facilities. These wastes are contaminated with various types of alpha, beta, and gamma nuclides. The contamination level of the decommissioning wastes must be surveyed for free release, but it is very difficult to monitor the radioactive contamination level of the pipe inside using conventional counting methods because of the small diameter. In this study a Phoswich detector for simultaneous counting of alpha- and beta-rays in a pipe was developed. The Phoswich detector is convenient for monitoring of alpha and beta contamination using only a single detector, which was composed of thin cylindrical ZnS(Ag) and plastic scintillator. The scintillator for counting an alpha particle has been applied a cylindrical polymer composite sheet, having a double layer structure of an inorganic scintillator ZnS(Ag) layer adhered onto a polymer sub-layer. The sub-layer in an alpha particle counting sheet is made of polysulfone, working as a mechanical and optical support. The ZnS(Ag) layer is formed by coating a ternary mixture of ZnS(Ag), cyano resin as a binder and solvent onto the top of a sub-layer via the screen printing method. The other layer for counting a beta particle used a commercially available plastic scintillator. The plastic scintillator was simulated by using the Monte Carlo simulation method for detection of beta radiation emitted from internal surfaces of small diameter pipe. Simulation results predicted the optimum thickness and geometry of plastic scintillator at which energy absorption for beta radiation was maximized. Characteristics of the detector fabricated were also estimated. As a result, it was confirmed that detector capability was suitable for counting the beta ray. The overall counting results reveal that the developed Phoswich detector is efficient for simultaneous counting of alpha and beta ray in a pipe. (authors)

  5. Improvement and automatization of a proportional alpha-beta counting system - FAG

    International Nuclear Information System (INIS)

    German, U.; Levinson, S.; Pelled, O.; Shemesh, Y.; Assido, H.

    1997-01-01

    An alpha and beta counting system - FAG*, for planchette samples is operated at the Health Physics department's laboratory of the NRCN. The original operation mode of the system was based on manual tasks handled by the FHT1 100 electronics. An option for a basic computer keyboard operation was available too. A computer with an appropriate I/O card was connected to the system and a new operating program was developed which enables full automatic control of the various components. The program includes activity calculations and statistical checks as well as data management. A bar-code laser system for sample number reading was integrated into the Alpha-Beta automatic counting system. The sample identification by means of an attached bar-code label enables unmistakable and reliable attribution of results to the counted sample. authors)

  6. GAS MOTION STUDY OF Ly{alpha} EMITTERS AT z {approx} 2 USING FUV AND OPTICAL SPECTRAL LINES {sup ,}

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, Takuya; Shimasaku, Kazuhiro; Nakajima, Kimihiko [Department of Astronomy, Graduate School of Science, The University of Tokyo, Tokyo 113-0033 (Japan); Ouchi, Masami; Ono, Yoshiaki [Institute for Cosmic Ray Research, The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8582 (Japan); Rauch, Michael; Janice Lee [Observatories of the Carnegie Institution of Washington, 813 Santa Barbara Street, Pasadena, CA 91101 (United States); Okamura, Sadanori, E-mail: thashimoto@astron.s.u-tokyo.ac.jp [Department of Advanced Sciences, Faculty of Science and Engineering, Hosei University, 3-7-2 Kajino-cho, Koganei-shi, Tokyo 184-8584 (Japan)

    2013-03-01

    We present the results of Magellan/MMIRS and Keck/NIRSPEC spectroscopy for five Ly{alpha} emitters (LAEs) at z {approx_equal} 2.2 for which high-resolution FUV spectra from Magellan/MagE are available. We detect nebular emission lines including H{alpha} on the individual basis and low-ionization interstellar (LIS) absorption lines in a stacked FUV spectrum, and measure average offset velocities of the Ly{alpha} line, {Delta}v {sub Ly{alpha}}, and LIS absorption lines, {Delta}v {sub abs}, with respect to the systemic velocity defined by the nebular lines. For a sample of eight z {approx} 2-3 LAEs without active galactic nucleus from our study and the literature, we obtain {Delta}v {sub Ly{alpha}} = 175 {+-} 35 km s{sup -1}, which is significantly smaller than that of Lyman-break Galaxies (LBGs), {Delta}v {sub Ly{alpha}} {approx_equal} 400 km s{sup -1}. The stacked FUV spectrum gives {Delta}v {sub abs} = -179 {+-} 73 km s{sup -1}, comparable to that of LBGs. These positive {Delta}v {sub Ly{alpha}} and negative {Delta}v {sub abs} suggest that LAEs also have outflows. In contrast to LBGs, however, the LAEs' {Delta}v {sub Ly{alpha}} is as small as |{Delta}v {sub abs}|, suggesting low neutral hydrogen column densities. Such a low column density with a small number of resonant scattering may cause the observed strong Ly{alpha} emission of LAEs. We find an anti-correlation between Ly{alpha} equivalent width (EW) and {Delta}v {sub Ly{alpha}} in a compilation of LAE and LBG samples. Although its physical origin is not clear, this anti-correlation result appears to challenge the hypothesis that a strong outflow, by means of a reduced number of resonant scattering, produces a large EW. If LAEs at z > 6 have similarly small {Delta}v {sub Ly{alpha}} values, constraints on the reionization history derived from the Ly{alpha} transmissivity may need to be revised.

  7. New advanced in alpha spectrometry by liquid scintillation methods

    International Nuclear Information System (INIS)

    McDowell, W.J.; Case, G.N.

    1979-01-01

    Although the ability to count alpha particles by liquid scintillation methods has been long recognized, limited use has been made of the method because of problems of high background and alpha energy identification. In recent years some new developments in methods of introducing the alpha-emitting nuclide to the scintillator, in detector construction, and in electronics for processing the energy analog and time analog signals from the detector have allowed significant alleviation of the problems of alpha spectrometry by liquid scintillation. Energy resolutions of 200 to 300 keV full peak width at half maximum and background counts of 99% of all beta plus gamma interference is now possible. Alpha liquid scintillation spectrometry is now suitable for a wide range of applications, from the accurate quantitative determination of relatively large amounts of known nuclides in laboratory-generated samples to the detection and identification of very small, subpicocurie amounts of alpha emitters in environmental-type samples. Suitable nuclide separation procedures, sample preparation methods, and instrument configurations are available for a variety of analyses

  8. Low-level measurements by liquid scintillation counting

    International Nuclear Information System (INIS)

    Schoenhofer, F.

    1991-01-01

    Liquid scintillation counting has become a convenient tool for analysis of many beta- and alpha-emitters even in ultra low-level concentration ranges. Extremely low background is achieved in a commercially available counter by an active shielding and heavy lead shielding. Thus special time saving radiochemical separation processes could be designed. Extremely simple sample preparation techniques can be used. Counting time can be reduced and sample throughput enhanced. Also precision can be enhanced. From the author's research, several applications are discussed. They include: tritium in water without enrichment, tritium in urine (excretion analysis), carbon-14 in samples like alcohol or vinegar, Rn-222 in water and air, even gaseous Kr-85. A simple and fast method for Sr-90 in environmental samples and food has been developed and the Ra-226-concentration in water can be measured as low as 30 mBq/l without any chemical separation or enrichment. The instrument has been used successfully for screening purposes after the Chernobyl accident as well as for monitoring groundwater after a large scale contamination in Lower Austria. Using a 'gross-beta-measurement' effluents from a nuclear installation are monitored, clearly showing advantages over traditional methods. α-β-discrimination reduces the background for alpha emitters to practically zero. Examples from the determination of Ra-226 in water are shown

  9. Development of low level alpha particle counting system

    International Nuclear Information System (INIS)

    Minobe, Masao; Kondo, Hiraku; Chinuki, Takashi; Hirano, Hiromichi

    1987-01-01

    Much attention has been paid to the trace analysis of uranium and thorium contained in the base material of LSI or VLSI, since the so-called ''soft-error'' of the memory device was known to be due to alpha particles emitted from these radioactive elements. We have developed an apparatus to meet the needs of estimating such a very small quantity of U and Th of the level of ppb, by directly counting alpha particles using a gas-flow type proportional counter. This method requires no sophisticated analytical skill, and the accuracy of the result is satisfactory. The instrumentation and some application of this apparatus are described. (author)

  10. Mechanisms of alpha emitter production in 12C induced reactions at 1 GeV

    International Nuclear Information System (INIS)

    Dufour, J.P.; Delagrange, H.; Del Moral, R.

    1982-01-01

    We present cross sections, mean projected recoil ranges and angular distributions of radioactive alpha emitters produced in 12 C-induced reactions at 1 GeV on targets ranging from Gd to Pb. We use a new technique of on-line electrostatic collection. The wide spectrum of produced isotopes corresponds to nuclei close to the target up to nuclei with as much as 60 nucleons less than the target. The intranuclear cascade calculations can reproduce the main features of nuclei having lost up

  11. The influence of nonuniform micro-distribution of alpha emitter on microdosimetry in cells

    International Nuclear Information System (INIS)

    Tian Yuan; Zhang Liang'an; Dai Guangfu

    2007-01-01

    Objective: To study the influence of nonuniform micro-distribution of alpha emitter on cellular S values(in the radioimmunotherapy). Methods: Emission of alpha particles is randomly simulated by Monte Carlo method; the incident energy and exit energy are calculated with interpolation technique based on the relationship between range and energy of alpha particle and the analytical Continuous Slowing Down Approximation (CSDA) model. So energy deposited in the target area can be obtained. To take 213 Po as an example, cellular S values with various cell dimensions and possible micro-distributions of radioactivity are calculated, such as linear increase, linear decrease, exponential increase and exponential decrease. Results: S values from cell to cell of uniform distribution showed no difference with the Hamacher's results. S values of different micro-distributions are distinguishing with each other. It is indicated that different micro-distributions of radioactivity will result in significant change of average chord length of alpha particles traveling in the target area, as well as the change of average stopping power over the chord, which is primary reason for differences of S values. Conclusions: The nonuniform micro-distributions show remarkable influence on cellular S values and hence should be taken consideration in cellular absorbed dose estimation, especially in microdosimetry. (authors)

  12. Treatment of solid waste highly contaiminated by alpha emitters

    International Nuclear Information System (INIS)

    Madic, C.; Breschet, C.; Vigreux, B.

    1990-01-01

    In the recent years, efforts have been made in order to reduce the amount of alpha emitters essentially plutonium isotopes present in the solid wastes produced either during research experiments on fuel reprocessing, done in the Radiochemistry building in the centre d'etudes nucleaires de FONTENAY-AUX-ROSES (CEA, FRANCE), or in the MARCOULE reprocessing plant (COGEMA, FRANCE). The goals defined for the treatments of these different wastes were: to reduce their α and β, Y contamination levels; to recover the plutonium, a highly valuable material, and to minimize its quantity to be discharged with the wastes. To achieve these goals leaching processes using electrogenerated Ag (II(a very aggressive agent for PuO 2 )) in nitric acid solutions, were developed and several facilities were designed and built to operate the processes. A brief description of the process and of the different facilities will be presented in this paper; the main results obtained in ELISE and PROLIXE are also summarized

  13. Reference sources for the calibration of surface contamination monitors - Beta-emitters (maximum beta energy greater than MeV) and alpha-emitters (International Standard Publication ISO 8769:1988)

    International Nuclear Information System (INIS)

    Stefanik, J.

    2001-01-01

    This International Standard specifies the characteristics of reference sources of radioactive surface contamination, traceable to national measurement standards, for the calibration of surface contamination monitors. This International Standard relates to alpha-emitters and to beta-emitters of maximum beta energy greater than 0,15 MeV. It does not describe the procedures involved in the use of these reference sources for the calibration of surface contamination monitors. Such procedures are specified in IEC Publication 325 and other documents. This International Standard specifies reference radiations for the calibration of surface contamination monitors which take the form of adequately characterized large area sources specified, without exception, in terms of activity and surface emission rate, the evaluation of these quantities being traceable to national standards

  14. Water quality - Measurement of gross alpha activity in non-saline water - Thick source method. 2. ed.

    International Nuclear Information System (INIS)

    2007-01-01

    This International Standard specifies a method for the determination of gross alpha activity in non-saline waters for alpha-emitting radionuclides which are not volatile at 350 degree Centigrade. It is possible to determine supported volatile radionuclides measured to an extent determined by half-life, matrix retention (of the volatile species) and the duration of measurement (counting time). The method is applicable to raw and potable waters. The range of application depends on the amount of suspended matter in the water and on the performance characteristics (background count rate and counting efficiency) of the counter. Gross alpha radioactivity is determined by using proportional counting or solid scintillation counting on water residue deposited on a planchet. Due to the strong absorption of the residue deposit, it is considered that the alpha emission from the surface is proportional to the alpha activity of the deposit. Gross alpha determination is not an absolute determination of the sample alpha radioactive content, but a relative determination referring to a specific alpha emitter which constitutes the standard calibration source. This type of determination is also known as alpha index. The sample is acidified to stabilize it, evaporated almost to dryness, converted to the sulfate form and then ignited at 350 degree Centigrade. A portion of the residue is transferred to a planchet and the alpha activity measured by counting in an alpha-particle detector or counting system previously calibrated against an alpha-emitting standard and the alpha activity concentration calculated. The paper provides information about scope, normative references, symbols, definitions and units, principle, reagents and equipment, procedure, contamination check, expression of results and test report

  15. The used epoxy matrix in immobilization sludge process of alpha emitter radioactive waste

    International Nuclear Information System (INIS)

    Walman, E.; Salimin, Z.; Johan, B.

    1998-01-01

    Immobilization of alpha emitter radioactive waste containing of ion complex of uranyl carbonate on uranium concentration ≤ 50 mg/l has been carried out using epoxy matrix. The first step of process is the coagulation of uranium with 1.3 mole/l of Ca(OH) 2 coagulant concentration on pH 8 to precipitate the calcium uranyl carbonate on uranium concentration ≤ g/l. The immobilization of calcium uranyl carbonate with epoxy matrix was done on variation of the ratio of resin epoxy and hardener of 1 : 1 (giving the maximum value of density and compressive strength), the increasing of precipitate loading capacity give the decreasing of compressive strength of embedded waste. The test of compressive strength and leaching was done for the embedded waste after its curing time using Paul Weber equipment and 7 days immersion of samples in normal water. On the precipitate loading capacity of 70%, the quality of embedded waste still conform to the standard quality value i.e. density 1.2 g/cm 3 , compressive strength 10 kN/cm 2 and there is not any release of radionuclide during leaching test (undetectable).. (author)

  16. A Method Validation for Determination of Gross Alpha and Gross Beta in Water Sample Using Low Background Gross Alpha/ Beta Counting System

    International Nuclear Information System (INIS)

    Zal Uyun Wan Mahmood; Norfaizal Mohamed; Nita Salina Abu Bakar

    2016-01-01

    Method validation (MV) for the measurement of gross alpha and gross beta activity in water (drinking, mineral and environmental) samples using Low Background Gross Alpha/ Beta Counting System was performed to characterize precision, accuracy and reliable results. The main objective of this assignment is to ensure that both the instrument and method always good performed and resulting accuracy and reliable results. Generally, almost the results of estimated RSD, z-score and U_s_c_o_r_e were reliable which are recorded as ≤30 %, less than 2 and less than 1.5, respectively. Minimum Detected Activity (MDA) was estimated based on the counting time of 100 minutes and present background counting value of gross alpha (0.01 - 0.35 cpm) and gross beta (0.50 - 2.18 cpm). Estimated Detection Limit (DL) was 0.1 Bq/ L for gross alpha and 0.2 Bq/ L for gross beta and expended uncertainty was relatively small of 9.77 % for gross alpha and 10.57 % for gross beta. Align with that, background counting for gross alpha and gross beta was ranged of 0.01 - 0.35 cpm and 0.50 - 2.18 cpm, respectively. While, sample volume was set at minimum of 500 mL and maximum of 2000 mL. These proven the accuracy and precision result that are generated from developed method/ technique is satisfactory and method is recommended to be used. Therefore, it can be concluded that the MV found no doubtful on the ability of the developed method. The test result showed the method is suitable for all types of water samples which are contained several radionuclides and elements as well as any impurities that interfere the measurement analysis of gross alpha and gross beta. (author)

  17. Characterization of actinide targets by low solid-angle alpha particle counting

    CERN Document Server

    Denecke, B; Pauwels, J; Robouch, P; Gilliam, D M; Hodge, P; Hutchinson, J M R; Nico, J S

    1999-01-01

    Actinide samples were characterized in an interlaboratory comparison between IRMM and NIST, including alpha-particle counting at defined low solid angle and counting in a 2 pi proportional gas counter. For this comparison, nine sup 2 sup 3 sup 3 UF sub 4 samples with high uniformity in the layer thickness were prepared at IRMM by deposition under vacuum. Polished silicon wafers were used as source substrates, and these were rotated during the deposition using a planetary rotation system. The estimated uncertainties for the defined low solid-angle methods were about 0.1% at both NIST and IRMM. The agreement of reported alpha-particle emission rates in the energy range 2.5-5.09 MeV was better than or equal to 0.02% for the defined solid-angle methods. When comparing total alpha-particle emission rates over the larger energy range 0-9 MeV (which includes all emissions from the daughter nuclides and the impurities), the agreement of the defined solid-angle methods was better than or equal to 0.05%. The 2 pi propo...

  18. Treatment of solid waste highly contaminated by alpha emitters

    International Nuclear Information System (INIS)

    Madic, C.; Breschet, C.; Vigreaux, B.

    1990-01-01

    In the recent years, efforts have been made in order to reduce the amount of alpha emitters essentially plutonium isotopes present in the solid wastes produced either during research experiments on fuel reprocessing, done in the Radiochemistry building in the centre d'etudes nuclearires de FONTENAY-AUX-ROSES (CEA, FRANCE), or in the MARCOULE reprocessing plant (COGEMA, FRANCE). The goals defined for the treatments of these different wastes were: to reduce their α and β, γ, contamination levels. and to recover the plutonium, an highly valuable material, and to minimize its quantity to be discharged with the wastes. To achieve these goals leaching processes using electrogenerated Ag (II (a very aggressive agent for PuO 2 )) in nitric acid solutions, were developed and several facilities were designed and built to operate the processes: ELISE and PROLIXE facilities: PILOT ASHES FACILITY for delete, the treatment of plutonium contaminated ashes (COGEMA, MARCOULE). A brief description of the process and of the different facilities will be presented in this paper; the main results obtained in ELISE and PROLIXE are also summarized

  19. Are the brightest Lyman Alpha Emitters at z=5.7 primeval galaxies?

    Science.gov (United States)

    Lidman, Christopher; Jones, Heath; Meisenheimer, Klaus; Pompei, Emanuela; Tapken, Christian; Vanzi, Leonardo; Westra, Eduard

    2008-03-01

    Wide-field, narrow-band surveys have proven to be effective at finding very high redshift galaxies that emit brightly in the Lyman alpha line, the so-called Lyman alpha emitters (LAEs). It was through this technique that the most distant spectroscopically confirmed galaxy, a galaxy at z=6.96, was discovered. Considerable effort is currently being spent on discovering these galaxies at ever higher redshifts by extending this technique into the near-IR. In contrast to this effort, there has been relatively little work on understanding these galaxies. In particular, how do LAEs relate to other high redshift galaxies, such as the galaxies discovered through broad band drop out techniques, and, perhaps, more importantly, what role do LAEs play in re-ionising the universe. We recently discovered two extremely luminous LAEs at z=5.7. These LAEs are among the brightest LAEs ever discovered at this redshift. In a recent paper by Mao et al. the brightest LAEs are associated to the most massive halos. We propose to use the IRAC 3.6 micron imager on Spitzer to measure the rest-frame optical flux of the these LAEs. With additional data from the near-IR (rest-frame UV) and very deep optical spectra around the Lyman alpha line, we propose to make a detailed study of the spectral energy distribution from the Lyman alpha line to the rest frame optical of these exceptional LAEs. These data will enable us to estimate the age and mass of the stellar burst that produces the Lyman alpha line, to estimate the contribution from an older stellar population, if any, and to estimate the fraction of Lyman continuum photons that can escape the galaxy and are thus available to reionise the universe.

  20. Preliminary study on the analysis of alpha emitters at working places in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hanna; Kim, Jeong In; Lee, Byoungil [Korea Hydro and Nuclear Power Co., Seoul (Korea, Republic of); Yoon, Suk Won [Korea Institute of Radiological and Medical Sciences National Radiation Emergency Medical Center, Seoul (Korea, Republic of)

    2012-10-15

    Over sea nuclear power plants have been reported cases of internal contamination by alpha nuclides. In many cases, stations encountered significant alpha contamination when aged/legacy equipment was disturbed or handled. Under normal operating conditions, transuranic radionuclides are contained within the fuel rods and therefore are not a contributor to radioactive contamination within a facility. However, transuranic radionuclides result from the presence of tramp-uranium contamination on the exterior of fuel elements. Fuel failures may develop during operating cycles due to a variety of causes, ranging from manufacturing defects to mechanical or abrasive damage. In case of domestic nuclear power plants, the pressure tube replacements in Wolsong Unit 1 and steam generator replacements in Kori Unit 1 were done. Due to deterioration of equipment in accordance with the long-term operation, the domestic nuclear power plants are expected to improve the facilities and the probability of internal exposure from alpha emitters is increasing. The domestic nuclear power plants are only keeping alpha radionuclides of the effluent from the exterior under constant surveillance. The representative areas of CV are just carried out continuous alpha monitoring in during a unit outage. So far, there is no other case with alpha nuclides analysis. As the domestic nuclear power plants are expected to improve the facilities, it is the time to take proactive measures to deal with internal contamination by alpha emitting radioactive elements. In this paper, the possible risk of internal exposure is based on preliminary experiments on the analysis of alpha emitting radioactive elements at working places in nuclear power plants.

  1. Method validation for simultaneous counting of Total α , β in Drinking Water using Liquid Scintillation Counter

    International Nuclear Information System (INIS)

    Al-Masri, M. S.; Nashawati, A.

    2014-05-01

    In this work, Method Validation Methods and Pulse Shape Analysis were validated to determine gross Alpha and Beta Emitters in Drinking Water using Liquid Scintillation Counter Win spectral 1414. Validation parameters include Method Detection Limit, Method Quantitation Limit, Repeatability Limit, Intermediate Precision, Trueness) Bias), Recovery Coefficient, Linearity and Uncertainty Budget in analysis. The results show that the Method Detection Limit and Method Quantitation Limit were 0.07, 0.24 Bq/l for Alpha emitters respectively, and 0.42, 1.4 Bq/l for Beta emitters, respectively. The relative standard deviation of Repeatability Limit reached 2.81% for Alpha emitters and 3.96% for Beta emitters. In addition to, the relative standard deviation of Intermediate Precisionis was 0.54% for Alpha emitters and 1.17% for Beta emitters. Moreover, the trueness was - 7.7% for Alpha emitters and - 4.5% for Beta emitters. Recovery Coefficient ranged between 87 - 96% and 88-101 for Alpha and Beta emitters, respectively. Linearity reached 1 for both Alpha and Beta emitters. on the other hand, Uncertainty Budget for all continents was 96.65% ,83.14% for Alpha and Beta emitters, respectively (author).

  2. Decreased levels of genuine large free hCG alpha in men presenting with abnormal semen analysis

    Directory of Open Access Journals (Sweden)

    Plas Eugen

    2011-08-01

    Full Text Available Abstract Background The pregnancy hormone human chorionic gonadotropin (hCG and its free subunits (hCG alpha, hCG beta are produced in the male reproductive tract and found in high concentrations in seminal fluid, in particular hCG alpha. This study aimed to elucidate changes in peptide hormone profiles in patients showing abnormal semen analyses and to determine the genuineness of the highly abundant hCG alpha. Methods Seminal plasma was obtained from 45 male patients undergoing semen analysis during infertility workups. Comprehensive peptide hormone profiles were established by a panel of immunofluorometric assays for hCG, hCG alpha, hCG beta and its metabolite hCG beta core fragment, placental lactogen, growth hormone and prolactin in seminal plasma of patients with abnormal semen analysis results (n = 29 versus normozoospermic men (n = 16. The molecular identity of large hyperglycosylated hCG alpha was analyzed by mass-spectrometry and selective deglycosylation. Results hCG alpha levels were found to be significantly lower in men with impaired semen quality (1346 +/- 191 vs. 2753 +/- 533 ng/ml, P = 0.022. Moreover, patients with reduced sperm count had reduced intact hCG levels compared with normozoospermic men (0.097 +/- 0.022 vs. 0.203 +/- 0.040 ng/ml, P = 0.028. Using mass-spectrometry, the biochemical identity of hCG alpha purified from seminal plasma was verified. Under non-reducing conditions in SDS-PAGE, hCG alpha isolated from seminal plasma migrated in a manner comparable with large free hCG alpha with an apparent molecular mass (Mr, app of 24 kDa, while hCG alpha dissociated from pregnancy-derived holo-hCG migrated at approximately 22 kDa. After deglycosylation with PNGase F under denaturing conditions, all hCG alpha variants showed an Mr, app of 15 kDa, indicating identical amino acid backbones. Conclusions The findings indicate a pathophysiological relevance of hCG, particularly its free alpha subunit, in spermatogenesis. The

  3. Comparison of MCNP6 and experimental results for neutron counts, Rossi-{alpha}, and Feynman-{alpha} distributions

    Energy Technology Data Exchange (ETDEWEB)

    Talamo, A.; Gohar, Y. [Argonne National Laboratory, 9700 S. Cass Ave., Lemont, IL 60439 (United States); Sadovich, S.; Kiyavitskaya, H.; Bournos, V.; Fokov, Y.; Routkovskaya, C. [Joint Institute for Power and Nuclear Research-Sosny, 99 Academician A.K. Krasin Str., Minsk 220109 (Belarus)

    2013-07-01

    MCNP6, the general-purpose Monte Carlo N-Particle code, has the capability to perform time-dependent calculations by tracking the time interval between successive events of the neutron random walk. In fixed-source calculations for a subcritical assembly, the zero time value is assigned at the moment the neutron is emitted by the external neutron source. The PTRAC and F8 cards of MCNP allow to tally the time when a neutron is captured by {sup 3}He(n, p) reactions in the neutron detector. From this information, it is possible to build three different time distributions: neutron counts, Rossi-{alpha}, and Feynman-{alpha}. The neutron counts time distribution represents the number of neutrons captured as a function of time. The Rossi-a distribution represents the number of neutron pairs captured as a function of the time interval between two capture events. The Feynman-a distribution represents the variance-to-mean ratio, minus one, of the neutron counts array as a function of a fixed time interval. The MCNP6 results for these three time distributions have been compared with the experimental data of the YALINA Thermal facility and have been found to be in quite good agreement. (authors)

  4. Treatment of solid waste highly contaminated by alpha emitters: Recent developments of leaching process with continuous electrolyte regeneration

    International Nuclear Information System (INIS)

    Madic, C.; Lecomte, M.; Vigreux, B.

    1990-01-01

    Development of processes for leaching solid waste contaminated by alpha or alphaβgamma emitters has been pursued at the Nuclear Research Center in Fontenay-aux-Roses, France with the recent active commissioning of two pilot facilities: the Elise glove box system in February 1987 and the Prolixe shielded hot cell in March 1988. The Elise facility is designed to handle alpha waste and the Prolixe facility is designed to handle alphaβgamma waste. The common goal of the studies conducted in these facilities is to define the operating conditions for declassification of solid waste, i.e. to ensure that the alpha concentration of this waste will be less than 3.7 x 10 6 Bq/kg after treatment, packaging and decay prior to storage in surface repositories. The leaching process developed is mainly based on the continuous electrolytic regeneration of an aggressive agent, AgII, which can induce the dissolution of PuO 2 , the most difficult compound to remove from the solid waste. This paper summarizes recent achievements in the development of this process. 11 refs., 8 figs., 6 tabs

  5. Treatment of solid waste highly contaminated by alpha emitters: recent developments of leaching process with continuous electrolyte regeneration

    International Nuclear Information System (INIS)

    Madic, C.; Lecomte, M.

    1990-01-01

    Development of processes for leaching solid waste contaminated by alpha or alpha/beta/gamma emitters has been pursued at the Nuclear Research Center in Fontenay-aux-Roses, France with the recent active commissioning of two pilot facilities: the Elise glove box system in February 1987 and the Prolixe shielded hot cell in March 1988. The Elise facility is designed to handle alpha waste and the Prolixe facility is designed to handle alpha/beta/gamma waste. The common goal of the studies conducted in these facilities is to define the operating conditions for declassification of solid waste, i.e. to ensure that the alpha concentration of this waste will be less than 3.7 x 10 6 Bq/kg after treatment, packaging and decay prior to storage in surface repositories. The leaching process developed is mainly based on the continuous electrolytic regeneration of an aggressive agent, AgII, which can induce the dissolution of PuO 2 , the most difficult compound to remove from the solid waste. This paper summarizes recent achievements in the development of this process

  6. Radiological control in a mine with a naturally occurring radioactive material: NORM: I assessment of activity concentration of alpha emitter with long half live in the air in a pilot plant

    International Nuclear Information System (INIS)

    Pereira, W.S.; Py Junior, D.A.; Silva, A.C.A.; Garcia Filho, O.

    2013-01-01

    The Ore Treatment Unit (OTU) supports a laboratory process responsible for the development of new chemical processes for uranium extraction from ore elements associated with uranium. In 2009, a pilot plant for extraction of uranium from a phosphate ore mine with uranium associated was implanted, which is a case of Naturally Occurring Radioactive Material (NORM) in a mine at Santa Quiteria, CE, Brazil. This pilot plant was supervised by the radiological protection service, aiming the Occupational Exposed Individual' safety (OEI). During the pilot plant operation the monitoring of radionuclides concentration in air was carried out. During the functioning of the pilot plant 63 high-vol air monitoring and posterior gross alpha counts were made in order to evaluate the alpha emitters. One sampling was made before the beginning of operations in order to evaluate the background which was estimated in 0.003 Bq m -3 . Monitoring results varied between 0.001 Bq m -3 and 0.162 Bq m -3 with the average equal to 0.041 Bq m -3 . 100 % of the results were below the derived limit for OEI which is equal to 0.360 Bq m -3 . Thirty results were below the derived limit for public exposure. By using this criterion the area must be classified as Supervised Area. In order to correctly classify the area, the internal exposure must also be measured. The small values of air concentration of long lived alpha emitters can be explained by the process of uranium extraction that is made by solvent in a wet way that creates few aerosol particles in air that can be monitored by this method. (author)

  7. Radiological control in a mine with a naturally occurring radioactive material: NORM: I assessment of activity concentration of alpha emitter with long half live in the air in a pilot plant

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, W.S.; Py Junior, D.A.; Silva, A.C.A.; Garcia Filho, O., E-mail: pereiraws@gmail.com [Industrias Nucleares do Brasil (INB), Pocos de Caldas, MG (Brazil). Unidade de Tratamento de Minerio. Grupo Multidisciplinar de Radioprotecao; Kelecom, A., E-mail: akelecom@id.uff.br [Universidade Federal Fluminense (LARARA-PLS/GETA/UFF), Niteroi, RJ (Brazil). Laboratorio de Radiobiologia e Radiometria Pedro Lopes dos Santos. Grupo de Estudos em Temas Ambientais; Pereira, J.R.S., E-mail: pereirarsj@gmail.com [Universidade Federal de Alfenas (UNIFAL), Pocos de Caldas, MG (Brazil)

    2013-07-01

    The Ore Treatment Unit (OTU) supports a laboratory process responsible for the development of new chemical processes for uranium extraction from ore elements associated with uranium. In 2009, a pilot plant for extraction of uranium from a phosphate ore mine with uranium associated was implanted, which is a case of Naturally Occurring Radioactive Material (NORM) in a mine at Santa Quiteria, CE, Brazil. This pilot plant was supervised by the radiological protection service, aiming the Occupational Exposed Individual' safety (OEI). During the pilot plant operation the monitoring of radionuclides concentration in air was carried out. During the functioning of the pilot plant 63 high-vol air monitoring and posterior gross alpha counts were made in order to evaluate the alpha emitters. One sampling was made before the beginning of operations in order to evaluate the background which was estimated in 0.003 Bq m{sup -3}. Monitoring results varied between 0.001 Bq m{sup -3} and 0.162 Bq m{sup -3} with the average equal to 0.041 Bq m{sup -3}. 100 % of the results were below the derived limit for OEI which is equal to 0.360 Bq m{sup -3}. Thirty results were below the derived limit for public exposure. By using this criterion the area must be classified as Supervised Area. In order to correctly classify the area, the internal exposure must also be measured. The small values of air concentration of long lived alpha emitters can be explained by the process of uranium extraction that is made by solvent in a wet way that creates few aerosol particles in air that can be monitored by this method. (author)

  8. PC based alpha, beta and gamma counting system

    International Nuclear Information System (INIS)

    Bhattacharya, S.; Gopalakrishnan, K.R.; Bairi, B.R.

    1992-01-01

    In the field of radiation protection and safety a large number of samples have to be assayed for estimation of their radioactivity at various stages in nuclear fuel. A PC based alpha, beta and gamma counting system has been designed for the above application. The system is fully automatic and requires minimum of operator intervention. The main units in the system are detector and pulse processing electronics, sample changer and assembly and IBM PC interface and supporting software. The main function of interface is to control the sample changer which is basically loading and unloading of sample, data acquisition and further processing by software. The pulses from detector are analysed in a pulse shape discriminator. A pulse identified as an alpha, beta or gamma event is converted to digital pulse. These digital pulses are accumulated in the three channels on PC interface each corresponding to alpha, beta and gamma. The sample movements are controlled by interface depending upon sample position. The software has been developed so as to maintain user friendliness and convenience of the operator. Various selection modes for parameters and operation of system provide lot of flexibility in operation of the system. (author). 1 fig

  9. Analysis of low energy beta-emitters

    International Nuclear Information System (INIS)

    Murphy, D.L.

    1979-10-01

    A survey was made of the instruments used for the determination of low energy beta radioactivity. Techniques commonly used are gas flow proportional counting, liquid scintillation counting, solid scintillation counting, and internal ionization chamber counting, solid state detector counting, and radiochemical separation followed by counting using one of the preceeding techniques. The first four techniques were examined and compared with each other. The sensitivities of the techniques were compared on the basis of the detection limits quoted for instruments described in the technical and reviewed literature. The detection limits were then related to the occupational and public individual maximum levels for air and water. Attention is focused primarily on the continuous monitoring of air for 3 H and 85 Kr, a medium energy β-emitter. It is clear that several continuous air monitoring instruments are readily available for measuring low energy β concentrations, even in presence of certain other activity, at occupational levels. However, these instruments do not typically have sensitivities comparable to the public individual levels. Moreover, their capabilities for giving results in real time and for differentiating among the radionuclides actually present is limited

  10. Critical review for the determination of the minimum detectable activity (MDA) of alpha-emitter radionuclides in environmental samples

    International Nuclear Information System (INIS)

    Gasco, C.; Anton, M.P.

    1996-12-01

    Different criteria for the calculation of the Minimum Detectable Activity (MDA) of an alpha emitter in environmental levels are reviewed in this report. Practical examples of its application to previously analyzed samples are shown. The authors propose a criteria based on prior calculations that applies to the radiochemical activities performed in the laboratory. The calculation procedure has been discussed with scientist from other laboratories in order to establish a general criteria to calculate the MDA

  11. Applications of alpha particles detectors made of nitrocellulose film

    International Nuclear Information System (INIS)

    Segovia, N.; Salinas, B.; Pineda, H.

    1978-01-01

    We describe the experiments realized in order to probe the response of the alpha particles detectors manufactured in our laboratory and their suitability to some important applications. The detection system is a nitrocellulose film which register the transit of the charged particles. The traces left by the particles during their transit are manifested through a controlled chemical attack and counted after that with a microscope. This monitor system was utilized in the following applications: 1) uranium prospection 2) alpha autoradiography 4) determination of air pollution by alpha emitters. The results which were obtained are satisfactory and in spite that in these first applications only qualitative measurements were made the method could be used for quantitative determinations when we will have a better knowledge of the effect of factors which are not under our control. (author)

  12. Alpha emitters activity measurement using the defined solid angle method

    International Nuclear Information System (INIS)

    Blanchis, P.

    1983-01-01

    The defined solid angle counting method can reach a very high accuracy, specially for heavy ions as alpha particles emitted by a radioactive source. The activity measurement of such sources with a relative uncertainty of the order of 0.01% is investigated. Such an accuracy is available only under suitable conditions: the radiation emitted by the source must be isotropic and all the particles emitted in the effective solid angle must be detected. The efficiency detection value must be equal to unity and phenomena such as absorption or scattering must be null. It is shown that corrections often become necessary. All parameters which can influence the measurements are studied [fr

  13. Sertoli cell specific knockdown of RAR-related orphan receptor (ROR) alpha at puberty reduces sperm count in rats.

    Science.gov (United States)

    Mandal, Kamal; Sarkar, Rajesh K; Sen Sharma, Souvik; Jain, Ayushi; Majumdar, Subeer S

    2018-01-30

    Globally, there is an alarming decline in sperm count. Very often hormonal supplementation fails to restore normal sperm count. Sertoli cells (Sc) present within seminiferous tubules provide appropriate niche and factors required for the differentiation of germ cells (Gc) into mature sperm (spermatogenesis). Functionally compromised Sc may be one of the reasons for failure of hormones to facilitate normal spermatogenesis. Although role of secretory proteins and signaling molecules of Sc has been studied well, role of transcription factors regulating sperm count has not been addressed appropriately. Retinoic acid receptor-related orphan receptor (ROR)-alpha is one of such transcription factors reported in testis but its role in testicular function is not yet known. In a separate study, we found abundant ROR-alpha binding sites on promoter regions of several genes upregulated in pubertal rat Sc as compared to infant Sc. Immunostaining studies also revealed presence of ROR alpha in nucleus of pubertal Sc. We generated a transgenic knockdown rat model expressing shRNA targeted to ROR-alpha under Sc specific promoter, which is transcriptionally active only at and after puberty. ROR-alpha knockdown animals were found to have abnormal association of Sc and Gc, including Gc sloughing and restricted release of sperm. The knockdown animals displayed compromised spermatogenesis leading to significant reduction in sperm count. This is the first report describing the Sc specific role of ROR-alpha in maintaining quantitatively normal sperm output. Identification of various such molecules can generate avenues to limit or reverse an alarmingly declining sperm count witnessed globally in men. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Determination of hCG-alpha subunit in threatened pregnancy

    International Nuclear Information System (INIS)

    Talas, M.; Pohanka, J.; Fingerova, H.; Janouskova, M.; Krikal, Z.; Prasilova, J.; Zupkova, H.

    1987-01-01

    Radioimmunoassay of the hCG-alpha subunit was made using an antibody anti hCG-alpha serum, highly purified hCG-alpha for 125 I-labelling and the standard hCG-alpha. Sera of healthy pregnant women sampled throughout the whole pregnancies were used to determine x-bar±S.D. of hCG-alpha for 14-day intervals. Included in the study were groups of women with high risk of premature labor, late toxemia of pregnancy, twins and fetal hypotrophy. It was shown that increased hCG-alpha is found in pregnant women in whom signs of late toxemia of pregnancy are combined with high risk of premature labor, or with twin pregnancies, while in those with fetal hypotrophy hCG-alpha is within normal limits. (author). 3 figs., 7 refs

  15. Nanodiamond Emitters of Single Photons

    Directory of Open Access Journals (Sweden)

    Vlasov I.I.

    2015-01-01

    Full Text Available Luminescence properties of single color centers were studied in nanodiamonds of different origin. It was found that single photon emitters could be realized even in molecularsized diamond (less than 2 nm capable of housing stable luminescent center “silicon-vacancy.” First results on incorporation of single-photon emitters based on luminescent nanodiamonds in plasmonic nanoantennas to enhance the photon count rate and directionality, diminish the fluorescence decay time, and provide polarization selectivity are presented.

  16. A bar-code reader for an alpha-beta automatic counting system - FAG

    Energy Technology Data Exchange (ETDEWEB)

    Levinson, S; Shemesh, Y; Ankry, N; Assido, H; German, U; Peled, O [Israel Atomic Energy Commission, Beersheba (Israel). Nuclear Research Center-Negev

    1996-12-01

    A bar-code laser system for sample number reading was integrated into the FAG Alpha-Beta automatic counting system. The sample identification by means of an attached bar-code label enables unmistakable and reliable attribution of results to the counted sample. Installation of the bar-code reader system required several modifications: Mechanical changes in the automatic sample changer, design and production of new sample holders, modification of the sample planchettes, changes in the electronic system, update of the operating software of the system (authors).

  17. A bar-code reader for an alpha-beta automatic counting system - FAG

    International Nuclear Information System (INIS)

    Levinson, S.; Shemesh, Y.; Ankry, N.; Assido, H.; German, U.; Peled, O.

    1996-01-01

    A bar-code laser system for sample number reading was integrated into the FAG Alpha-Beta automatic counting system. The sample identification by means of an attached bar-code label enables unmistakable and reliable attribution of results to the counted sample. Installation of the bar-code reader system required several modifications: Mechanical changes in the automatic sample changer, design and production of new sample holders, modification of the sample planchettes, changes in the electronic system, update of the operating software of the system (authors)

  18. Measurement of the absolute activity of alpha or beta emitters by measuring product nuclei (daughter) activity increase or by studing its radioactive decay

    International Nuclear Information System (INIS)

    Campos, L.C. de.

    1981-01-01

    A new method for determining absolute activity of alpha or beta emitters by measuring daughter product radioactive decay is presented. The separation method of UX from hexahydrated uranyl nitrate UO 2 (NO 3 ) 2 6H 2 O based on its dissolution in ethyl ether is described and the accuracy of this method is shown. The factors which accuate on total efficiency of a Geiger Mueller detector for beta particles are determined. The possibility to determine the mass of precursor element by daughter nuclei activity is shown. The results are compared with the one obtained by direct measurement of the mass (or number of atoms) of precursor radioactive substance and with theoretical values calculated for isotopes in secular equilibrium. (Author) [pt

  19. Early bone changes after incorporation of low quantities of alpha emitters in male rats

    International Nuclear Information System (INIS)

    Laengle, U.W.

    1988-09-01

    This work shows the early effects of cancergenic doses of alpha emitters in long bones of rats. The investigations were based on radiographic, morphologic, angiographic, histologic and electronmicroscopic methods. A special method for bone angiography in the rat was elaborated and a new method was developed for measurement of the femur neck-head angle. Numerous disturbances in bone growth and bone structure, in the blood supply of bone and also of the bone building cells were observed. There was a correlation between the severity of the damage and the radiation dose, the spacial distribution of the nuclide and partially the age of the rats. The bone injury due to plutonium was markedly reduced by administration of the chelating agent Zn-DTPA. (orig.) [de

  20. Estimation of low level gross alpha activities in the radioactive effluent using liquid scintillation counting technique

    International Nuclear Information System (INIS)

    Bhade, Sonali P.D.; Johnson, Bella E.; Singh, Sanjay; Babu, D.A.R.

    2012-01-01

    A technique has been developed for simultaneous measurement of gross alpha and gross beta activity concentration in low level liquid effluent samples in presence of higher activity concentrations of tritium. For this purpose, alpha beta discriminating Pulse Shape Analysis Liquid Scintillation Counting (LSC) technique was used. Main advantages of this technique are easy sample preparation, rapid measurement and higher sensitivity. The calibration methodology for Quantulus1220 LSC based on PSA technique using 241 Am and 90 Sr/ 90 Y as alpha and beta standards respectively was described in detail. LSC technique was validated by measuring alpha and beta activity concentrations in test samples with known amount of 241 Am and 90 Sr/ 90 Y activities spiked in distilled water. The results obtained by LSC technique were compared with conventional planchet counting methods such as ZnS(Ag) and end window GM detectors. The gross alpha and gross beta activity concentrations in spiked samples, obtained by LSC technique were found to be within ±5% of the reference values. (author)

  1. {alpha} counting device with pulse ionization chamber; Ensemble de comptage {alpha} a chambre d'ionisation a impulsion

    Energy Technology Data Exchange (ETDEWEB)

    Engelman, J; Guillon, H [Commissariat a l' Energie Atomique, Saclay(France). Centre d' Etudes Nucleaires

    1953-07-01

    This device has been achieved more especially in view of the control, by measure of activity {alpha}, of chemical separations. The sought-after features were the following: - simple handling; possibility to do some measures fast and frequent. It imposed the choice of an ionization chamber at air pressure; - possibility to count {alpha} in presence of a continuous {beta} background noise, which imposed a resolution time as short as possible; - absence of micro-phonics, which imposed a study of suspension of the room; - great safety of use. (author) [French] Cet appareil a ete realise plus particulierement en vue du controle, par mesure d'activite {alpha}, de separations chimiques. Les caracteristiques recherchees etaient les suivantes: - maniement simple; possibilite d'effectuer des mesures rapides et frequentes. Cela imposait le choix d'une chambre d'ionisation a air a pression atmospherique; - possibilite de compter des {alpha} en presence d'un fond continu de {beta}, ce qui imposait un temps de resolution aussi court que possible; - absence de microphonie, ce qui demandait une etude du mode de suspension de la chambre; - grande securite de fonctionnement. (auteur)

  2. Treatment of solid waste highly contaminated by alpha emitters: Low-temperature impact crushing, leaching and incineration

    International Nuclear Information System (INIS)

    Bertolotti, G.; Vigreux, B.; Caillol, A.; Koehly, G.

    1987-01-01

    Reprocessing plants, hot laboratories and fuel fabrication plants produce solid wastes containing residual amounts of plutonium and uranium in nitrate and oxide form at concentrations up to several tens of grams per m/sup 3/. Dismantling of nuclear facilities having handled these radioelements also generates large volumes of solid wastes highly contaminated with alpha emitters. It is desirable to process these alpha wastes to recover valuable fissile materials and/or permit surface storage. Solid waste treatment by low-temperature impact crushing and then leaching, after minimal sorting and classifying at the sites of production, meets the corresponding requirements for high volume reduction plus fissile material recovery or waste decontamination. Additional volume reduction of crushed wastes containing mainly combustible materials can be obtained by incineration. This is facilitated by the low fissile material content after low-temperature impact crushing and leaching. Sorted wastes can also be leached or incinerated directly after, in most cases, crushing by more conventional techniques

  3. Emittance measurements for optimum operation of the J-PARC RF-driven H{sup −} ion source

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, A., E-mail: akira.ueno@j-parc.jp; Ohkoshi, K.; Ikegami, K.; Takagi, A.; Yamazaki, S.; Oguri, H. [J-PARC Center, Tokai-mura, Naka-gun, Ibaraki-ken 319-1195 (Japan)

    2015-04-08

    In order to satisfy the Japan Proton Accelerator Research Complex (J-PARC) second stage requirements of an H{sup −} ion beam of 60mA within normalized emittances of 1.5πmm•mrad both horizontally and vertically, a flat top beam duty factor of 1.25% (500μs×25Hz) and a life-time of longer than 1month, the J-PARC cesiated RF-driven H{sup −} ion source was developed by using an internal-antenna developed at the Spallation Neutron Source (SNS). The transverse emittances of the source were measured with various conditions to find out the optimum operation conditions minimizing the horizontal and vertical rms normalized emittances. The transverse emittances were most effectively reduced by operating the source with the plasma electrode temperature lower than 70°C. The optimum value of the cesium (Cs) density around the beam hole of the plasma electrode seems to be proportional to the plasma electrode temperature. The fine control of the Cs density is indispensable, since the emittances seem to increase proportionally to the excessiveness of the Cs density. Furthermore, the source should be operated with the Cs density beyond a threshold value, since the plasma meniscus shape and the ellipse parameters of the transverse emittances seem to be changed step-function-likely on the threshold Cs value.

  4. Quantitative autoradiography of alpha particle emission in geo-materials using the Beaver™ system

    International Nuclear Information System (INIS)

    Sardini, Paul; Angileri, Axel; Descostes, Michael; Duval, Samuel; Oger, Tugdual; Patrier, Patricia; Rividi, Nicolas; Siitari-Kauppi, Marja; Toubon, Hervé; Donnard, Jérôme

    2016-01-01

    In rocks or artificial geo-materials, radioactive isotopes emitting alpha particles are dispersed according to the mineralogy. At hand specimen scale, the achievement of quantitative chemical mapping of these isotopes takes on a specific importance. Knowledge of the distribution of the uranium and thorium series radionuclides is of prime interest to several disciplines, from the geochemistry of uranium deposits, to the dispersion of uranium mill tailings in the biosphere. The disequilibrium of these disintegration chains is also commonly used for dating. However, some prime importance isotopes, such as 226 Ra, are complicated to localize in geo-materials. Because of its high specific activity, 226 Ra is found in very low concentrations (~ppq), preventing its accurate localization in rock forming minerals. This paper formulates a quantitative answer to the following question: at hand specimen scale, how can alpha emitters in geo-materials be mapped quantitatively? In this study, we tested a new digital autoradiographic method (called the Beaver™) based on a Micro Patterned Gaseous Detector (MPGD) in order to quantitatively map alpha emission at the centimeter scale rock section. Firstly, for two thin sections containing U-bearing minerals at secular equilibrium, we compared the experimental and theoretical alpha count rates, measured by the Beaver™ and calculated from the uranium content, respectively. We found that they are very similar. Secondly, for a set of eight homemade standards made up of a mixture of inactive sand and low-radioactivity mud, we compared the count rates obtained by the Beaver™ and by an alpha spectrometer. The results indicate (i) a linearity between both count rates, and (ii) that the count obtained by the Beaver™ can be estimated from the count obtained by the alpha spectrometry using a factor of 0.82.

  5. Quantitative autoradiography of alpha particle emission in geo-materials using the Beaver™ system

    Energy Technology Data Exchange (ETDEWEB)

    Sardini, Paul; Angileri, Axel [IC2MP Equipe HydrASA, 6 Rue Michel Brunet, B35, TSA 51106 Poitiers Cedex 9 (France); Descostes, Michael [AREVA Mines, R& D Department, Paris (France); Duval, Samuel; Oger, Tugdual [AI4R SAS, Nantes (France); Patrier, Patricia [IC2MP Equipe HydrASA, 6 Rue Michel Brunet, B35, TSA 51106 Poitiers Cedex 9 (France); Rividi, Nicolas [Service Camparis, Université Pierre et Marie Curie, Paris (France); Siitari-Kauppi, Marja [Radiochemistry Laboratory, University of Helsinki, Helsinki (Finland); Toubon, Hervé [AREVA Mines, R& D Department, Paris (France); Donnard, Jérôme [AI4R SAS, Nantes (France)

    2016-10-11

    In rocks or artificial geo-materials, radioactive isotopes emitting alpha particles are dispersed according to the mineralogy. At hand specimen scale, the achievement of quantitative chemical mapping of these isotopes takes on a specific importance. Knowledge of the distribution of the uranium and thorium series radionuclides is of prime interest to several disciplines, from the geochemistry of uranium deposits, to the dispersion of uranium mill tailings in the biosphere. The disequilibrium of these disintegration chains is also commonly used for dating. However, some prime importance isotopes, such as {sup 226}Ra, are complicated to localize in geo-materials. Because of its high specific activity, {sup 226}Ra is found in very low concentrations (~ppq), preventing its accurate localization in rock forming minerals. This paper formulates a quantitative answer to the following question: at hand specimen scale, how can alpha emitters in geo-materials be mapped quantitatively? In this study, we tested a new digital autoradiographic method (called the Beaver™) based on a Micro Patterned Gaseous Detector (MPGD) in order to quantitatively map alpha emission at the centimeter scale rock section. Firstly, for two thin sections containing U-bearing minerals at secular equilibrium, we compared the experimental and theoretical alpha count rates, measured by the Beaver™ and calculated from the uranium content, respectively. We found that they are very similar. Secondly, for a set of eight homemade standards made up of a mixture of inactive sand and low-radioactivity mud, we compared the count rates obtained by the Beaver™ and by an alpha spectrometer. The results indicate (i) a linearity between both count rates, and (ii) that the count obtained by the Beaver™ can be estimated from the count obtained by the alpha spectrometry using a factor of 0.82.

  6. Monitoring of gross alpha, gross beta and tritium activities in portuguese drinking waters

    International Nuclear Information System (INIS)

    Lopes, I.; Madruga, M.J.; Ferrador, G.O.; Sequeira, M.M.; Oliveira, E.J.; Gomes, A.R.; Rodrigues, F.D.; Carvalho, F.P.

    2006-01-01

    The gross beta and tritium activities in the forty Portuguese drinking waters analyzed using the ISO standard methods (Portuguese Guidelines) are below the guidance levels proposed in the Portuguese Drinking Water Quality Guidelines. In what concerns the gross alpha activity only 18% exceeded the recommended level. In general, it can be concluded that the ingestion of these drinking waters does not create a radiological hazard to the human consumption, however, more detailed analyses will be necessary mainly the determinations of the individual alpha emitters radionuclide concentrations. The minimum gross alpha and gross beta detectable activities by L.S.C. methodology are higher than for the proportional counting technique (ISO method). Higher concentration factors will be needed to reach lower required detection limits. (authors)

  7. Gross alpha and gross beta determination in surface and groundwater water by liquid scintillation counting (LSC)

    International Nuclear Information System (INIS)

    Faria, Ligia S.; Moreira, Rubens M.

    2013-01-01

    The present study has used 40 samples of groundwater and surface water collected at four different sites along the period of one year in Brumadinho and Nova Lima, two municipalities in the State of Minas Gerais, Brazil, as part of a more extensive study aiming at determination of the natural radioactivity in the water used for domestic use. These two sites are inside an Environmental Protection Area is located in a region of very intensive iron ore exploration. In addition of mineral resources, the region has a geological characteristic that includes quartzitic conglomerates associated with uranium. Radioactivity levels were determined via liquid scintillation counting (LSC), a fast and high counting efficiency method that can be advantageously employed to determine gross alpha and gross beta activity in liquid samples. Previously to gross alpha and gross beta counting the samples were acidified with concentrated HNO 3 in the field. The technique involved a pre-concentration of the sample to obtain a low detection limit. Specific details of the employed methodology are commented. The results showed that concentrations of gross alpha natural activity and gross beta values ranged from less than the detection limit of the equipment (0.03 Bq.L -1 ) to 0.275 ± 0.05 Bq.L -1 for gross alpha. As regards gross beta, all samples were below the limit of detection. (author)

  8. PHYSICAL PROPERTIES OF Ly{alpha} EMITTERS AT z {approx} 0.3 FROM UV-TO-FIR MEASUREMENTS

    Energy Technology Data Exchange (ETDEWEB)

    Oteo, I.; Bongiovanni, A.; Perez Garcia, A. M.; Cepa, J.; Pintos-Castro, I. [Instituto de Astrofisica de Canarias (IAC), E-38200 La Laguna, Tenerife (Spain); Ederoclite, A. [Centro de Estudios de Fisica del Cosmos de Aragon, Plaza San Juan 1, Planta 2, Teruel, 44001 (Spain); Sanchez-Portal, M.; Altieri, B. [Herschel Science Centre (ESAC), Villafranca del Castillo (Spain); Perez-Martinez, R. [XMM/Newton Science Operations Centre (ESAC), Villafranca del Castillo (Spain); Lutz, D.; Berta, S.; Foerster Schreiber, N.; Genzel, R.; Magnelli, B. [Max-Planck-Institut fuer Extraterrestrische Physik (MPE), Postfach 1312, 85741 Garching (Germany); Andreani, P. [ESO, Karl-Schwarzchild-Str. 2, D-85748 Garching (Germany); Aussel, H.; Daddi, E.; Elbaz, D.; Le Floc' h, E. [Commissariat a l' Energie Atomique (CEA-SAp) Saclay (France); Cimatti, A. [Dipartimento di Astronomia, Universita di Bologna, Via Ranzani 1, 40127 Bologna (Italy); and others

    2012-06-01

    The analysis of the physical properties of low-redshift Ly{alpha} emitters (LAEs) can provide clues in the study of their high-redshift analogs. At z {approx} 0.3, LAEs are bright enough to be detected over almost the entire electromagnetic spectrum and it is possible to carry out a more precise and complete study than at higher redshifts. In this work, we examine the UV and IR emission, dust attenuation, star formation rate (SFR), and morphology of a sample of 23 GALEX-discovered star-forming LAEs at z {approx} 0.3 with direct UV (GALEX), optical (ACS), and FIR (PACS and MIPS) data. Using the same UV and IR limiting luminosities, we find that LAEs at z {approx} 0.3 tend to be less dusty, have slightly higher total SFRs, have bluer UV continuum slopes, and are much smaller than other galaxies that do not exhibit Ly{alpha} emission in their spectrum (non-LAEs). These results suggest that at z {approx} 0.3, Ly{alpha} photons tend to escape from small galaxies with low dust attenuation. Regarding their morphology, LAEs belong to Irr/merger classes, unlike non-LAEs. Size and morphology represent the most noticeable difference between LAEs and non-LAEs at z {approx} 0.3. Furthermore, the comparison of our results with those obtained at higher redshifts indicates either that the Ly{alpha} technique picks up different kind of galaxies at different redshifts or that the physical properties of LAEs are evolving with redshift.

  9. Summary of alpha-neutron sources in GADRAS

    International Nuclear Information System (INIS)

    Mitchell, Dean James; Thoreson, Gregory G.; Harding, Lee T.

    2012-01-01

    A common source of neutrons for calibration and testing is alpha-neutron material, named for the alpha-neutron nuclear reaction that occurs within. This material contains a long-lived alpha-emitter and a lighter target element. When the alpha particle from the emitter is absorbed by the target, neutrons and gamma rays are released. Gamma Detector Response and Analysis Software (GADRAS) includes built-in alpha-neutron source definitions for AcC, AmB, AmBe, AmF, AmLi, CmC, and PuC. In addition, GADRAS users may create their own alpha-neutron sources by placing valid alpha-emitters and target elements in materials within their one-dimensional models (1DModel). GADRAS has the ability to use pre-built alpha-neutron sources for plotting or as trace-sources in 1D models. In addition, if any material (existing or user-defined) specified in a 1D model contains both an alpha emitter in conjunction with a target nuclide, or there is an interface between such materials, then the appropriate neutron-emission rate from the alpha-neutron reaction will be computed. The gamma-emissions from these sources are also computed, but are limited to a subset of nine target nuclides. If a user has experimental data to contribute to the alpha-neutron gamma emission database, it may be added directly or submitted to the GADRAS developers for inclusion. The gadras.exe.config file will be replaced when GADRAS updates are installed, so sending the information to the GADRAS developers is the preferred method for updating the database. This is also preferable because it enables other users to benefit from your efforts.

  10. Are the brightest Lyman Alpha Emitters at zD5.7 primeval galaxies?

    Science.gov (United States)

    Lidman, Christopher; Hayes, Matthew; Jones, Heath; Meisenheimer, Klaus; Tapken, Christian; Westra, Eduard

    2009-04-01

    Wide-field, narrow-band surveys have proven to be effective at finding very high redshift galaxies that emit brightly in the Lyman alpha line - the so-called Lyman alpha emitters (LAEs). It was through this technique that the most distant spectroscopically confirmed galaxy, a galaxy at zD6.96 (Iye et al. 2006), was discovered. Considerable effort is currently being spent on discovering these galaxies at ever higher redshifts by extending this technique into the near-IR. In contrast to this effort, there has been relatively little work on understanding these galaxies. In particular, how do LAEs relate to other high redshift galaxies, such as those discovered through drop out techniques, and, more importantly, what role LAEs play in re-ionising the universe, if any. We recently discovered two extremely luminous LAEs at zD5.7. These LAEs are among the brightest LAEs ever discovered at this redshift. In a recent paper by Mao et al. (2007), the brightest LAEs are associated to the most massive halos. One of these targets was successfully observed with the IRAC 3.6 micron imager on Spitzer during cycle 5. These data, when combined with constraints that we derive from our deep ground-based spectroscopic data, indicate that the bulk of the flux at 3.6 microns comes from a stellar population that is considserably older than the stars that dominate the flux in the UV. We propose to complete the project and image the second target. These data will enable us to estimate the age and mass of the stellar burst that produces the Lyman alpha line, to estimate the contribution from an older stellar population and to estimate the fraction of Lyman continuum photons that escape the galaxy and are thus available to re-ionise the universe.

  11. Spectral Ly{alpha}, Ly{beta}, and H{alpha} line shapes for the H atom in the presence of a magnetic field in a plasma; Profils des raies spectrales Ly{alpha}, Ly{beta}, et H{alpha} de l'atome H en presence d'un champ magnetique dans un plasma

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, H; Herman, L [Laboratoire de Recherches Physiques, Faculte des sciences, 9 Quai Saint Bernard, 75 - Paris (France); Drawin, H W [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1967-02-15

    This report contains numerical data of the line shapes of Ly{alpha}, Ly{beta}, and H{alpha} for the following parameters: 1. 10{sup 2} {<=} H [gauss] {<=} 1.2. 10{sup 5} 1. 10{sup 15}{<=} N [cm{sup -3}] {<=} 1. 10{sup 18} cm{sup -3} 1. 10{sup 4} {<=} T [deg. K] {<=} 4. 10{sup 4} where H = magnetic field strength, K = density of plasma ions, T = electron temperature. (authors) [French] Dans ce rapport, on donne les valeurs numeriques des contours des raies spectrales Ly{alpha}, Ly{beta}, et H{alpha} pour les valeurs suivantes des parametres H, N et T 1. 10{sup 2} {<=} H [gauss] {<=} 1.2. 10{sup 5} 1. 10{sup 15}{<=} N [cm{sup -3}] {<=} 1. 10{sup 18} cm{sup -3} 1. 10{sup 4} {<=} T [deg. K] {<=} 4. 10{sup 4} ou H intensite du champ magnetique, N = densite des ions, T = temperature electronique. (auteurs)

  12. Monte Carlo simulation of the spectral response of beta-particle emitters in LSC systems

    International Nuclear Information System (INIS)

    Ortiz, F.; Los Arcos, J.M.; Grau, A.; Rodriguez, L.

    1992-01-01

    This paper presents a new method to evaluate the counting efficiency and the effective spectra at the output of any dynodic stage, for any pure beta-particle emitter, measured in a liquid scintillation counting system with two photomultipliers working in sum-coincidence mode. The process is carried out by a Monte Carlo simulation procedure that gives the electron distribution, and consequently the counting efficiency, at any dynode, in response to the beta particles emitted, as a function of the figure of merit of the system and the dynodic gains. The spectral outputs for 3 H and 14 C have been computed and compared with experimental data obtained with two sets of quenched radioactive standards of these nuclides. (orig.)

  13. Transverse beam emittance optimization for the injection into BESSY II

    Energy Technology Data Exchange (ETDEWEB)

    Kramer, Felix [Helmholtz Zentrum Berlin, Institut Beschleunigerphysik (Germany); Humboldt-Universitaet zu Berlin, Institut fuer Physik (Germany)

    2016-07-01

    For top up injection into the storage ring BESSY II an average injection efficiency of at least 90% is required. In low alpha mode the injection efficiency does not meet the requirements. Future BESSY II features will include shorter bunches in the storage ring (VSR) and user transparent injection with a non linear kicker. These will raise the demands on the quality of the injected beam even further. This work investigates the development of transverse emittance over the acceleration cycle in the synchrotron and the possibility of transverse emittance exchange by a sequence of skew quadrupoles in the transfer line. Results of emittance measurements and emittance exchange simulations will be given.

  14. Alternating sample changer and an automatic sample changer for liquid scintillation counting of alpha-emitting materials

    International Nuclear Information System (INIS)

    Thorngate, J.H.

    1977-08-01

    Two sample changers are described that were designed for liquid scintillation counting of alpha-emitting samples prepared using solvent-extraction chemistry. One operates manually but changes samples without exposing the photomultiplier tube to light, allowing the high voltage to remain on for improved stability. The other is capable of automatically counting up to 39 samples. An electronic control for the automatic sample changer is also described

  15. Previous study for the setting up and optimization of detection of ZnS(Ag) scintillation applied to the measure of alpha radioactivity index

    International Nuclear Information System (INIS)

    Pujol, L.; Suarez-Navarro, J.A.; Montero, M.

    1998-01-01

    The determination of radiological water quality is useful for a wide range of environmental studies. In these cases, the gross alpha activity is one of the parameters to determine. This parameter permits to decide if further radiological analyses are necessary in order to identify and quantify the presence of alpha emitters in water. The usual method for monitoring the gross alpha activity includes sample evaporation to dryness on a disk and counting using ZnS(Ag) scintillation detector. Detector electronics is provided with two components which are adjustable by the user the high-voltage applied to the photomultiplier tubes and the low level discriminator that is used to eliminate the electronic noise. The high-voltage and low level discriminator optimization are convenient in order to reach the best counting conditions. This paper is a preliminary study of the procedure followed for the setting up and optimization of the detector electronics in the laboratories of CEDEX for the measurement of gross alpha activity. (Author)

  16. Effect of the CO2/SiH4 Ratio in the p-μc-SiO:H Emitter Layer on the Performance of Crystalline Silicon Heterojunction Solar Cells

    Directory of Open Access Journals (Sweden)

    Jaran Sritharathikhun

    2014-01-01

    Full Text Available This paper reports the preparation of wide gap p-type hydrogenated microcrystalline silicon oxide (p-μc-SiO:H films using a 40 MHz very high frequency plasma enhanced chemical vapor deposition technique. The reported work focused on the effects of the CO2/SiH4 ratio on the properties of p-μc-SiO:H films and the effectiveness of the films as an emitter layer of crystalline silicon heterojunction (c-Si-HJ solar cells. A p-μc-SiO:H film with a wide optical band gap (E04, 2.1 eV, can be obtained by increasing the CO2/SiH4 ratio; however, the tradeoff between E04 and dark conductivity must be considered. The CO2/SiH4 ratio of the p-μc-SiO:H emitter layer also significantly affects the performance of the solar cells. Compared to the cell using p-μc-Si:H (CO2/SiH4 = 0, the cell with the p-μc-SiO:H emitter layer performs more efficiently. We have achieved the highest efficiency of 18.3% with an open-circuit voltage (Voc of 692 mV from the cell using the p-μc-SiO:H layer. The enhancement in the Voc and the efficiency of the solar cells verified the potential of the p-μc-SiO:H films for use as the emitter layer in c-Si-HJ solar cells.

  17. Solar Imagery - Chromosphere - H-Alpha

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Collection includes a variety of H-alpha photographic datasets contributed by a number of national and private solar observatories located worldwide. Solar...

  18. Investigation of the performance of alpha particle counting and alpha-gamma discrimination by pulse shape with micro-pixel avalanche photodiode

    International Nuclear Information System (INIS)

    Ahmadov, G.; Madatov, R.; Sadigov, A.; Sadygov, Z.; Jafarova, E.; Ahmadov, G.; Sadygov, Z.; Olshevski, A.; Zerrouk, F.; Mukhtarov, R.

    2015-01-01

    Being capable measuring small lights gives possibility to use micro-pixel avalanche photodiodes with scintillators. It is shown two prototypes to use micro-pixel avalanche photodiodes with and without scintillators as alpha and gamma counters in this paper. First prototype is to use two micro-pixel avalanche photodiodes. One for detecting alpha particles and closer to it, the second one with a thin plastic scintillator for detecting gamma rays. Second prototype is called two-layers configuration in which it is used only one micro-pixel avalanche photodiode, but two scntillators with different decay times. One can distinquish alpha particle and gamma ray events by using pulse shape discrimination techniques in the two-layer configuration. In this work an alpha particle and gamma ray counting performance of micro-pixel avalanche photodiodes without scintillators and its combination of plastic and BGO+ plastic scintillators was investigated. Obtained results showed the detection performance of the micro-pixel avalanche photodiodes in combination with plastic scintillator was about the same as conventional semiconductor detectors

  19. Intraperitoneal alpha-radioimmunotherapy in mice using different specific activities

    DEFF Research Database (Denmark)

    Elgqvist, Jörgen; Andersson, Håkan; Haglund, Elin

    2009-01-01

    The aim of this study was to investigate the therapeutic efficacy of the alpha-radioimmunotherapy of ovarian cancer in mice, using different specific activities. This study was performed by using the monoclonal antibody, MX35 F(ab')(2), labeled with the alpha-particle-emitter, 211At.......The aim of this study was to investigate the therapeutic efficacy of the alpha-radioimmunotherapy of ovarian cancer in mice, using different specific activities. This study was performed by using the monoclonal antibody, MX35 F(ab')(2), labeled with the alpha-particle-emitter, 211At....

  20. Microcontroller based motion control interface unit for double slit type beam emittance monitor for H- ion source

    International Nuclear Information System (INIS)

    Holikatti, A.C.; Jain, Rahul; Karnewar, A.K.; Sonawane, B.B.; Maurya, N.K.; Puntambekar, T.A.

    2015-01-01

    The Indian Spallation Neutron Source (ISNS), proposed to be developed at RRCAT, will use a 1 GeV H - linac and an accumulator ring to produce high flux of pulsed neutrons via spallation process. The development activity of front end of 1H - linac for ISNS is under progress at RRCAT, for which a pulsed H - ion source of 50 keV energy, 30 mA current with pulse width of 500 μs has been developed at RRCAT. In this paper, we present the design and development of a microcontroller based motion control interface unit for double slit type beam emittance monitor for the H - ion source. This is an interceptive type of beam diagnostic device, which is used for the quantitative measurement of transverse emittance and beam intensity profile

  1. Experiences with large-area frisch grid chambers in low-level alpha spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Hoetzl, H.; Winkler, R. (Gesellschaft fuer Strahlen- und Umweltforschung m.b.H. Muenchen, Neuherberg (Germany, F.R.). Inst. fuer Strahlenschutz)

    1984-06-15

    The properties of parallel-plate gridded ionization chambers with areas of 300 cm/sup 2/, developed by us for alpha spectrometry of samples with low specific alpha activity are reported. Several practical hints for optimum operating conditions are presented. The chambers can be operated routinely at atmospheric pressure for several days, without the need for purification of the gas filling (P10). The minimum detectable activity at 5 MeV is 0.01 pCi, based on 4.65 standard deviations of background and 1000 min counting time. At the GSF Research Center ionization chambers of this type are used for the analysis of natural alpha emitters, as well as of transuranium nuclides in environmental samples by: a) direct alpha spectrometry without any previous treatment of the sample, b) semi-direct spectrometry after removal of organic matter by low-temperature ashing and c) spectrometry after chemical separation. Some typical example of application are given. Furthermore the range of application of the chambers in comparison to semiconductor detectors in the field of low-level alpha spectrometry is discussed.

  2. Experiences with large-area frisch grid chambers in low-level alpha spectrometry

    International Nuclear Information System (INIS)

    Hoetzl, H.; Winkler, R.

    1984-01-01

    The properties of parallel-plate gridded ionization chambers with areas of 300 cm 2 , developed by us for alpha spectrometry of samples with low specific alpha activity are reported. Several practical hints for optimum operating conditions are presented. The chambers can be operated routinely at atmospheric pressure for several days, without the need for purification of the gas filling (P10). The minimum detectable activity at 5 MeV is 0.01 pCi, based on 4.65 standard deviations of background and 1000 min counting time. At the GSF Research Center ionization chambers of this type are used for the analysis of natural alpha emitters, as well as of transuranium nuclides in environmental samples by: a) direct alpha spectrometry without any previous treatment of the sample, b) semi-direct spectrometry after removal of organic matter by low-temperature ashing and c) spectrometry after chemical separation. Some typical example of application are given. Furthermore the range of application of the chambers in comparison to semiconductor detectors in the field of low-level alpha spectrometry is discussed. (orig.)

  3. Development of optical monitor of alpha radiations based on CR-39.

    Science.gov (United States)

    Joshirao, Pranav M; Shin, Jae Won; Vyas, Chirag K; Kulkarni, Atul D; Kim, Hojoong; Kim, Taesung; Hong, Seung-Woo; Manchanda, Vijay K

    2013-11-01

    Fukushima accident has highlighted the need to intensify efforts to develop sensitive detectors to monitor the release of alpha emitting radionuclides in the environment caused by the meltdown of the discharged spent fuel. Conventionally, proportional counting, scintillation counting and alpha spectrometry are employed to assay the alpha emitting radionuclides but these techniques are difficult to be configured for online operations. Solid State Nuclear Track Detectors (SSNTDs) offer an alternative off line sensitive technique to measure alpha emitters as well as fissile radionuclides at ultra-trace level in the environment. Recently, our group has reported the first ever attempt to use reflectance based fiber optic sensor (FOS) to quantify the alpha radiations emitted from (232)Th. In the present work, an effort has been made to develop an online FOS to monitor alpha radiations emitted from (241)Am source employing CR-39 as detector. Here, we report the optical response of CR-39 (on exposure to alpha radiations) employing techniques such as Atomic Force Microscopy (AFM) and Reflectance Spectroscopy. In the present work GEANT4 simulation of transport of alpha particles in the detector has also been carried out. Simulation includes validation test wherein the projected ranges of alpha particles in the air, polystyrene and CR-39 were calculated and were found to agree with the literature values. An attempt has been further made to compute the fluence as a function of the incidence angle and incidence energy of alphas. There was an excellent correlation in experimentally observed track density with the simulated fluence. The present work offers a novel approach to design an online CR-39 based fiber optic sensor (CRFOS) to measure the release of nanogram quantity of (241)Am in the environment. © 2013 Elsevier Ltd. All rights reserved.

  4. DEVELOPMENT OF AN ON-LINE, REAL-TIME ALPHA RADIATION MEASURING INSTRUMENT FOR LIQUID STREAMS

    International Nuclear Information System (INIS)

    1996-01-01

    The Department of Energy (DOE) has expressed a need for an on-line, real-time instrument for assaying alpha-emitting radionuclides (uranium and the transuranics) in effluent waters leaving DOE sites to ensure compliance with regulatory limits. Due to the short range of alpha particles in water (approximately40 Tm), it is necessary now to intermittently collect samples of water and send them to a central laboratory for analysis. A lengthy and costly procedure is used to separate and measure the radionuclides from each sample. Large variations in radionuclide concentrations in the water may go undetected due to the sporadic sampling. Even when detected, the reading may not be representative of the actual stream concentration. To address these issues, Tecogen, a division of Thermo Power Corporation, a Thermo Electron company, is developing a real-time, field-deployable, alpha monitor based on a solid-state silicon wafer semiconductor (patent pending, to be assigned to the Department of Energy). The Thermo Alpha Monitor (TAM) will serve to monitor effluent water streams (Subsurface Contaminants Focus Area) and will be suitable for process control of remediation as well as decontamination and decommissioning operations, such as monitoring scrubber or rinse water radioactivity levels (Mixed Waste Focus Area and D and D Focus Area). It would be applicable for assaying other liquids, such as oil, or solids after proper preconditioning. Rapid isotopic alpha air monitoring is also possible using this technology. This instrument for direct counting of alpha-emitters in aqueous streams is presently being developed by Thermo Power under a development program funded by the DOE Environmental Management program (DOE-EM), administered by the Morgantown Energy Technology Center (METC). Under this contract, Thermo Power has demonstrated a solid-state, silicon-based semiconductor instrument, which uses a proprietary film-based collection system to quantitatively extract the

  5. Study on influences of experimental factors on energy and absolute activity measurements of alpha-emitters

    International Nuclear Information System (INIS)

    Terini, R.A.

    1991-01-01

    This work presents firstly a review of the fundamental results and conclusions obtained through alpha-spectrometry and alpha-counting, and the influence of energy straggling, energy loss, self-absorption and backscattering, on the determination of the energy and the absolute activity of alpha samples. Is is shown that the techniques of source fabrication and the methods of measurements play a capital influence on the obtained results. Moreover, measurements made by us, with a silicon surface barrier detector, show that the peak-asymmetry and peak-shift of an alpha-spectrum increases with the angle of emission, and that the magnitude of this effect depends on the thickness and homogeneity of the sample, as well as on the geometry of the measuring system. Through an analysis of the angular distribution of the emitted particles, the degree of isotropy of some thin Am sup(241) sources was measured and the influence of source backing and the geometry was analysed. We can conclude that, in general, there is a larger precision in measurements made under very small solid angles around the normal to the sample, and we enphasize the necessary cares required on the production of the source and on the set up of the measuring system. (author)

  6. Problems in radiological protection involving alpha emitters in bone

    International Nuclear Information System (INIS)

    Dolphin, G.W.

    1976-01-01

    Quantitative dose/effect relationships for humans exposed to α emitters can only be established from data on humans exposed to this type of radiation. The risk of bone sarcoma from exposure to plutonium-239 may be established from the data on the human cases exposed to radium-226 either by consideration of the radiation dose to the osteoprogenitor cells or by use of the average bone dose together with a modifying factor to take into account the greater toxicity of plutonium relative to radium. The relative toxicity can be evaluated from the data on osteosarcoma incidence in animals. Both methods of risk estimation are given and criticised in the paper. In future recommendations, ICRP will not use the critical organ concept and the late effects from α emitters deposited in organs other than the bone will have to be taken into account in setting maximum permissible annual intakes. The implications of this and other proposed changes in ICRP concepts are discussed. (orig.) [de

  7. Relationship between {sup 63}Ni and {sup 3}H in an environmental monitoring program for water of a nuclear facility

    Energy Technology Data Exchange (ETDEWEB)

    Idoeta, R.; Herranz, M.; Legarda, F. [Universidad del Pais Vasco UPV/EHU (Spain); De Lucas, M.J. [Medidas Ambientales S.L. (Spain)

    2014-07-01

    During four years deep water coming from twelve different sampling points in the neighborhood of a nuclear facility have been quarterly analyzed for different radionuclides ({sup 63}Ni, {sup 55}Fe, {sup 90}Sr, {sup 14}C, {sup 3}H, {sup 240+239}Pu, {sup 241}Am, {sup 243+244}Cm, gross alpha, gross beta and gamma emitters) and for typical chemical components (pH, Conductivity (25 deg. C), Chlorides, Bicarbonates, Sulfates, Calcium, Magnesium, Sodium and Potassium). Sampling points are well characterized by measuring in situ and in every sampling campaign, its level (m), temperature, depth, pH, conductivity and free oxygen (mg/l). For the determination of alpha and beta specific radionuclides, methods, equipment and measurement parameters were chosen to be able to obtain low detection limits in order to characterize these waters. These detection limits, obtained following the ISO 11929 standard methodology, were around 2E-01 Bq/m{sup 3} for alpha emitters, around 2E+01 Bq/m{sup 3} for {sup 63}Ni, and {sup 55}Fe and around 3E+03 Bq/m{sup 3} for {sup 14}C and {sup 3}H. Despite these low detection limits, only small amounts of {sup 3}H and {sup 63}Ni have been systematically detected in some of these waters. These artificial radionuclides have different origins, being {sup 3}H mainly a tertiary fission product and {sup 63}Ni an activation product. {sup 3}H was determined by distillation followed by liquid scintillation counting (LSC) and {sup 63}Ni was determined by radiochemical isolation using specific Ni-resin, followed also by LSC. In this work, the relationship between {sup 3}H and {sup 63}Ni content values is obtained and analyzed and a multivariate analysis among the chemical water components and its {sup 3}H and {sup 63}Ni contents has been carried out in order to explain the behaviour of these radionuclides and its migration from the facility to the deep waters. Document available in abstract form only. (authors)

  8. Effect of metallic iron on the oxidative dissolution of UO2 doped with a radioactive alpha emitter in synthetic Callovian-Oxfordian groundwater

    Science.gov (United States)

    Odorowski, Mélina; Jegou, Christophe; De Windt, Laurent; Broudic, Véronique; Jouan, Gauthier; Peuget, Sylvain; Martin, Christelle

    2017-12-01

    In the hypothesis of direct disposal of spent fuel in a geological nuclear waste repository, interactions between the fuel mainly composed of UO2 and its environment must be understood. The dissolution rate of the UO2 matrix, which depends on the redox conditions on the fuel surface, will have a major impact on the release of radionuclides into the environment. The reducing conditions expected for a geological disposal situation would appear to be favorable as regards the solubility and stability of the UO2 matrix, but may be disturbed on the surface of irradiated fuel. In particular, the local redox conditions will result from a competition between the radiolysis effects of water under alpha irradiation (simultaneously producing oxidizing species like H2O2, hydrogen peroxide, and reducing species like H2, hydrogen) and those of redox active species from the environment. In particular, Fe2+, a strongly reducing aqueous species coming from the corrosion of the iron canister or from the host rock, could influence the dissolution of the fuel matrix. The effect of iron on the oxidative dissolution of UO2 was thus investigated under the conditions of the French disposal site, a Callovian-Oxfordian clay formation chosen by the French National Radioactive Waste Management Agency (Andra), here tested under alpha irradiation. For this study, UO2 fuel pellets doped with a radioactive alpha emitter (238/239Pu) were leached in synthetic Callovian-Oxfordian groundwater (representative of the French waste disposal site groundwater) in the presence of a metallic iron foil to simulate the steel canister. The pellets had varying levels of alpha activity, in order to modulate the concentrations of species produced by water radiolysis on the surface and to simulate the activity of aged spent fuel after 50 and 10,000 years of alpha radioactivity decay. The experimental data showed that whatever the sample alpha radioactivity, the presence of iron inhibits the oxidizing dissolution of

  9. Variable Emittance Electrochromics Using Ionic Electrolytes and Low Solar Absorptance Coatings

    Science.gov (United States)

    Chandrasekhar, Prasanna

    2011-01-01

    One of the last remaining technical hurdles with variable emittance devices or skins based on conducting polymer electrochromics is the high solar absorptance of their top surfaces. This high solar absorptance causes overheating of the skin when facing the Sun in space. Existing technologies such as mechanical louvers or loop heat pipes are virtually inapplicable to micro (solar absorption to Alpha(s) of between 0.30 and 0.46. Coupled with the emittance properties of the variable emittance skins, this lowers the surface temperature of the skins facing the Sun to between 30 and 60 C, which is much lower than previous results of 100 C, and is well within acceptable satellite operations ranges. The performance of this technology is better than that of current new technologies such as microelectromechanical systems (MEMS), electrostatics, and electrophoretics, especially in applications involving micro and nano spacecraft. The coatings are deposited inside a high vacuum, layering multiple coatings onto the top surfaces of variable emittance skins. They are completely transparent in the entire relevant infrared region (about 2 to 45 microns), but highly reflective in the visible-NIR (near infrared) region of relevance to solar absorptance.

  10. ALPHA/AMPU, Radionuclide Radioactivity from Alpha Spectrometer Measurements

    International Nuclear Information System (INIS)

    Sill, D.S.

    1990-01-01

    1 - Description of program or function: The two computer programs, ALPHA and AMPU, take raw data obtained from alpha spectrometry and from these calculate activities and uncertainties of the radionuclides present in the sample. ALPHA determines activities of any alpha emitter in a sample that has been directly precipitated with NdF 3 . AMPU determines the Pu-239, Pu-238,and Am-241 activities using Pu-236 and Am-243 tracers. 2 - Method of solution: These programs propagate all random and systematic uncertainties, found anywhere in the experimental process, to the final result. The result is rounded and is in decimal agreement with the uncertainty. 3 - Restrictions on the complexity of the problem: In ALPHA, a chemical yield of 98% is assumed

  11. Optimization in the nuclear fuel cycle II: Concentration of alpha emitters in the air; Otimização no ciclo do combustível nuclear II: concentração de alfa emissores no ar

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, W.S., E-mail: pereiras@gmail.com [Universidade Veiga de Ameida (UVA), Rio de Janeiro, RJ (Brazil); Silva, A.X.; Lopes, J.M.; Carmo, A.S.; Mello, C.R.; Fernandes, T.S., E-mail: lararapls@hotmail.com, E-mail: Ademir@nuclear.ufrj.br [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil); Kelecom, A. [Universidade Federal Fluminense (UFF), Niterói, RJ (Brazil)

    2017-07-01

    Optimization is one of the bases of radioprotection and aims to move doses away from the dose limit that is the borderline of acceptable radiological risk. The work aims to use the monitoring of the concentration of alpha emitters in the air as a tool of the optimization process. We analyzed 27 sampling points of airborne alpha concentration in a nuclear fuel cycle facility. The monthly averages were considered statistically different, the highest in the month of February and the lowest in the month of August. All other months were found to have identical mean activity concentration values. Regarding the sampling points, the points with the highest averages were points 12, 15 and 9. These points were indicated for the beginning of the optimization process. Analysis of the production of the facility should be performed to verify possible correlations between production and concentration of alpha emitters in the air.

  12. Fetal dosimetry from natural alpha emitters

    Energy Technology Data Exchange (ETDEWEB)

    Purnell, S.J

    1999-09-01

    The size of marrow cavities in fetal vertebra, rib and sternum was investigated using an image analysis system. The average chord lengths through marrow spaces in the vertebrae were found to increase approximately linearly with gestational age from 140 {mu}m at 20 weeks to 300 {mu}m at 40 weeks. Average chord lengths through marrow spaces in fetal rib and sternum were 330 {mu}m at 35 weeks in both cases. These results can be compared with an average chord length across marrow spaces in adult vertebra of 1172 {mu}m. At natural background UK exposure, activity concentrations of supported {sup 210}Po in fetal bone of 0.075 Bq kg{sup -1} and 0.15 Bq kg{sup -1} at mid- and late gestation respectively were calculated. Monte Carlo simulations modelling the paths of alpha-particles in fetal vertebra gave a total alpha-radiation dose to marrow over the second and third trimesters of 32.0 {+-} 0.8 {mu}Sv with the {sup 210}Po in bone contributing 8.9 {+-} 0.9 {mu}Sv. The dose to primitive haemopoietic stem cells, the target cells for acute lymphoblastic leukaemia, and the survival of these stem cells following a hit by an alpha-particle was investigated, also using Monte Carlo simulations. Alpha-particles emitted from bone and marrow contributed an average dose of 1.9 Gy to stem cells with a nuclear diameter of 3.8 {mu}m. This study has estimated that 1% of babies born each year are born with a mutated primitive haemopoietic stem cell due to in utero irradiation from high LET radiation. That is 7,320 babies compared to an estimated 300 incidences of cALL each year initiated in utero. The probability that a mutated cell will go on to give rise to leukaemia is unknown but it would seem not unlikely that irradiation in utero plays a substantial part in the induction of childhood leukaemia. (author)

  13. Recurrent mass ejections observed in H-alpha and CIV

    International Nuclear Information System (INIS)

    Schmieder, B.; Simon, G.

    1984-01-01

    Time sequences of recurrent mass ejections have been observed during a coordinated SMY program (Sept. 1, 1980 - Sept. 23, 1980 - Oct. 2, 1980). Comparison of the temporal evolution of H-alpha and CIV brightnesses shows a weak phase lag between H-alpha and CIV maxima, in the case of homologous flares, with CIV brightness maxima preceding H-alpha maxima. The analysis of the variation of the ejection velocities is expected to lead to the determination of an energy balance. Such recurrent ejections could be due to periodic energy storage and periodic reorganization of magnetic field as envisaged to occur for flares, but at lower energy levels

  14. Quality control of radiation counting systems and measurement of minimum detectable activity

    International Nuclear Information System (INIS)

    Song, Byoung Chul; Han, Sung Sim; Kim, Young Bok; Jee, Kwang Yong; Sohn, Se Chul

    2004-01-01

    Various radiation counters have been using to determine radioactivity of radwastes for disposal. A radiation counting system was set up using a radiation detector chosen in this study and its stability was investigated through the periodic determination of background and counting efficiencies in accordance with a quality control program to increase the confidence level. The average background level for the γ-spectrometer was 1.59 cps and the average counting level for the standard sample was 45248 dps within 20 confidence levels. The average alpha background level for the low background α/β counting system was 0.31 cpm and the efficiency for alpha counting was 34.38 %. The average beta background level for the α/β counting system was 1.30 cpm and the efficiency for beta counting was 46.5%. The background level in the region of 3H and 14C for the liquid scintillation counting system was 2.52 and 3.31 cpm and the efficiency for alpha counting was 58.5 and 95.6%, respectively. The minimum detectable activity for the γ-spectrometer was found to be 3.2 Bq/mL and 3.8 Bq/mL for the liquid scintillation counter, and 20.5 and 23.0 Bq/mL, respectively for the α and β counting system

  15. Alpha/beta pulse shape discrimination in plastic scintillation using commercial scintillation detectors

    International Nuclear Information System (INIS)

    Bagan, H.; Tarancon, A.; Rauret, G.; Garcia, J.F.

    2010-01-01

    Activity determination in different types of samples is a current need in many different fields. Simultaneously analysing alpha and beta emitters is now a routine option when using liquid scintillation (LS) and pulse shape discrimination. However, LS has an important drawback, the generation of mixed waste. Recently, several studies have shown the capability of plastic scintillation (PS) as an alternative to LS, but no research has been carried out to determine its capability for alpha/beta discrimination. The objective of this study was to evaluate the capability of PS to discriminate alpha/beta emitters on the basis of pulse shape analysis (PSA). The results obtained show that PS pulses had lower energy than LS pulses. As a consequence, a lower detection efficiency, a shift to lower energies and a better discrimination of beta and a worst discrimination of alpha disintegrations was observed for PS. Colour quenching also produced a decrease in the energy of the particles, as well as the effects described above. It is clear that in PS, the discrimination capability was correlated with the energy of the particles detected. Taking into account the discrimination capabilities of PS, a protocol for the measurement and the calculation of alpha and beta activities in mixtures using PS and commercial scintillation detectors has been proposed. The new protocol was applied to the quantification of spiked river water samples containing a pair of radionuclides ( 3 H- 241 Am or 90 Sr/ 90 Y- 241 Am) in different activity proportions. The relative errors in all determinations were lower than 7%. These results demonstrate the capability of PS to discriminate alpha/beta emitters on the basis of pulse shape and to quantify mixtures without generating mixed waste.

  16. Large area gridded ionisation chamber and electrostatic precipitator and their application to low-level alpha-spectrometry of environmental air samples

    International Nuclear Information System (INIS)

    Hoetzl, H.; Winkler, R.

    1977-01-01

    A high-resolution, parallel plate Frisch grid ionization chamber with an efficient area of 3000 cm 2 , and a large area electrostatic precipitator were developed and applied to direct alpha spectrometry of air dust. Using an argon-methane mixture (P-10 gas) at atmospheric pressure the resolution of the detector system is 22 keV FWHM at 5 MeV. After sampling for one week and decay of short-lived natural activity, the sensitivity of the procedure for long-lived alpha emitters is about 0.1 fCi/m 3 taking 3 Σσ of background as the detection limit with 1000 min counting time. (author)

  17. The determination of airborne concentrations of radon and thoron progeny by repetitive alpha counting of filter samples

    International Nuclear Information System (INIS)

    French, Clayton S. Jr.; Skrable, Kenneth W.; Chabot, George E.

    1978-01-01

    Analytical equations have been used to determine the airborne concentrations of the particulate daughters of radon and thoron from five net alpha counts obtained at preset time intervals post sampling. The same expressions were used to propagate the associated standard deviations. These propagated errors were minimized by the selection of optimum sampling and counting intervals. An extensive error analysis examined sources of interference and their influence on the calculated concentrations. This system offers sufficient precision for research applications, yet is simple and inexpensive enough for application in field studies. The radon and thoron daughters measured with this technique are 218 Po, 214 Pb, 214 Bi, 212 Pb, and 212 Bi. Because of the decay kinetics involved, the calculated concentrations of 218 Po and 212 Bi involve the greatest uncertainty. The proper choice of sampling and counting intervals optimizes the system for any one of the above radionuclides or for all five collectively. A sampling time of 15 minutes is best for the simultaneous estimation of all five concentrations. Millipore filter samples were obtained from a large, unventilated sub-basement of the University of Lowell research reactor facility and were counted later in direct contact with the window of a gas flow proportional detector having alpha particle counting efficiencies near 0.4 ca -1 and an alpha background of about 1 c min -1 . A typical 15 minute sample obtained at a flow rate of 2 x 10 4 cm 3 min -1 yielded estimates of the airborne concentrations and relative standard deviations: 218 Po, 4.75 x 10 -9 μCi cm -3 ± 18.9%; 214 Pb, 5.15 x 10 -9 μCi cm -3 ± 2.5%; 214 Bi, 4.86 x 10 -9 μCi cm -3 ± 2.4%; 212 Pb, 1.41 x 10 -10 μCi cm -3 ± 2.0%; and 212 Bi, 2.15 x 10 -10 μCi cm -3 ± 27.0%. (author)

  18. Dosimetry of internal emitters

    International Nuclear Information System (INIS)

    Anon.

    1982-01-01

    The Dosimetry of Internal Emitter Program endeavors to refine the correlation between radiation dose and observed biological effects. The program is presently engaged in the development of studies that will demonstrate the applicability of microdosimetry models developed under the Microdosimetry of Internal Sources Program. The program also provides guidance and assistance to Pacific Northwest Laboratory's Biology Department in the dosimetric analysis of internally deposited radionuclides. This report deals with alpha particle dosimetry plutonium 239 inhalation, and in vitro studies of chromosomal observations

  19. Radon counting statistics - a Monte Carlo investigation

    International Nuclear Information System (INIS)

    Scott, A.G.

    1996-01-01

    Radioactive decay is a Poisson process, and so the Coefficient of Variation (COV) of open-quotes nclose quotes counts of a single nuclide is usually estimated as 1/√n. This is only true if the count duration is much shorter than the half-life of the nuclide. At longer count durations, the COV is smaller than the Poisson estimate. Most radon measurement methods count the alpha decays of 222 Rn, plus the progeny 218 Po and 214 Po, and estimate the 222 Rn activity from the sum of the counts. At long count durations, the chain decay of these nuclides means that every 222 Rn decay must be followed by two other alpha decays. The total number of decays is open-quotes 3Nclose quotes, where N is the number of radon decays, and the true COV of the radon concentration estimate is 1/√(N), √3 larger than the Poisson total count estimate of 1/√3N. Most count periods are comparable to the half lives of the progeny, so the relationship between COV and count time is complex. A Monte-Carlo estimate of the ratio of true COV to Poisson estimate was carried out for a range of count periods from 1 min to 16 h and three common radon measurement methods: liquid scintillation, scintillation cell, and electrostatic precipitation of progeny. The Poisson approximation underestimates COV by less than 20% for count durations of less than 60 min

  20. Treatment of solid waste highly contaminated by alpha emitters. Recent developments of leaching process with continuous electrolyte regeneration

    International Nuclear Information System (INIS)

    Madic, C.

    1990-01-01

    In the recent years, efforts have been made in order to reduce the amount of alpha emitters essentially plutonium isotopes present in the solid wastes produced during research experiments on fuel reprocessing. Leaching processes using electrogenerated Ag (II(a very agressive agent for PuO 2 )) in nitric acid solutions, were developed and several facilities were designed and built to operate the processes: (1) ELISE and PROLIXE facilities, for the treatment of α and α, β, γ solid wastes (CEA, FONTENAY-AUX-ROSES) (2) PILOT ASHES FACILITY for delete, the treatment of plutonium contaminated ashes (COGEMA, MARCOULE). A brief description of the process and of the different facilities is presented; the main results obtained in ELISE and PROLIXE are also summarized

  1. Towards control of aggregational behaviour of alpha-lactalbumin at acidic pH.

    Science.gov (United States)

    Pedersen, Jane B; Fojan, Peter; Sorensen, John; Petersen, Steffen B

    2006-07-01

    alpha-Lactalbumin (alpha-La) undergoes considerable structural changes upon loss of bound Ca2+ at acidic pH, leaving alpha-La in a molten globule structure. Using fluorescence the present work provides more insight into the structural transition of alpha-La at acidic pH leading to protein aggregation, most likely caused by a combination of hydrophobic and electrostatic interactions. The rate of aggregation is determined by the protein concentration and temperature applied. Availability of Ca2+ stabilises the protein, and thus prevent aggregation at pH values as low as pH 2.9. In contrast, presence of Cu2+ induces a destabilisation of the protein, which can be explained by a binding to the Zn2+ binding site in alpha-La, possibly resulting in structural alterations of the protein. In general, presence of anions destabilize alpha-La at pH values below pI, with SO4(2-) exhibiting the strongest effect on the protein stability, thus correlating well with the Hofmeister series. At more acidic pH values far from pI, alpha-La becomes more stable towards ion induced aggregation, since higher ion activity is required to efficiently screen the charges on the protein surface. The results presented in this paper provide detailed knowledge on the external parameters leading to aggregation of alpha-La at acidic pH, thus permitting rational design of the aggregation process.

  2. Few remarks on the absolute counting of {beta} emitters using 4 {pi} counter; Quelques remarques sur la mesure absolue des emetteurs {beta} au compteur 4 {pi}

    Energy Technology Data Exchange (ETDEWEB)

    Grinberg, B; Le Gallic, Y [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    This study looks to determinate the optimum experimental conditions which allow the best accuracy possible for the absolute counting of {beta} emitters when using a 4 {pi} counter. The study has been done with a 4 {pi} counter using source supports of 30 {mu}m thickness. The associated electronic circuit includes: high-voltage, a 1000 scale and a dead time preafier of 4x10{sup -4} {mu}s. In addition, a coincidence preamplifier - with 1 {mu}s resolution time - was added which permits to count the coincidence between the measuring channels. It compares the measurement accuracy and the absorption correction needed for different source supports including polymers thin films with and without metal coating. (M.P.)

  3. Validation the quantification of beta emitters activity in urine by scintillation spectrometry in the liquid phase

    International Nuclear Information System (INIS)

    Sierra, I.; Hernandez, C.; Benito, P.; Lopez, C.

    2013-01-01

    In this paper the methodology used in the validation of the technique for quantifying activity of some beta emitters in urine ( 3 H, 1 4C, 3 5S, 3 2P and 9 0Sr) by scintillation spectrometry Liquid Phase (Liquid Scintillation Counting, LSC) is described in bio elimination Laboratory Service CIEMAT Radiation Dosimetry accredited since last year for carrying out assays measure radiation dose based on ISO forth above. (Author)

  4. Measuring Beam Sizes and Ultra-Small Electron Emittances Using an X-ray Pinhole Camera.

    Science.gov (United States)

    Elleaume, P; Fortgang, C; Penel, C; Tarazona, E

    1995-09-01

    A very simple pinhole camera set-up has been built to diagnose the electron beam emittance of the ESRF. The pinhole is placed in the air next to an Al window. An image is obtained with a CCD camera imaging a fluorescent screen. The emittance is deduced from the size of the image. The relationship between the measured beam size and the electron beam emittance depends upon the lattice functions alpha, beta and eta, the screen resolution, pinhole size and photon beam divergence. The set-up is capable of measuring emittances as low as 5 pm rad and is presently routinely used as both an electron beam imaging device and an emittance diagnostic.

  5. Estimation of atomic interaction parameters by photon counting

    DEFF Research Database (Denmark)

    Kiilerich, Alexander Holm; Mølmer, Klaus

    2014-01-01

    Detection of radiation signals is at the heart of precision metrology and sensing. In this article we show how the fluctuations in photon counting signals can be exploited to optimally extract information about the physical parameters that govern the dynamics of the emitter. For a simple two......-level emitter subject to photon counting, we show that the Fisher information and the Cram\\'er- Rao sensitivity bound based on the full detection record can be evaluated from the waiting time distribution in the fluorescence signal which can, in turn, be calculated for both perfect and imperfect detectors...

  6. Rapid monitoring of soil, smears, and air dusts by direct large-area alpha spectrometry

    International Nuclear Information System (INIS)

    Sill, C.W.

    1992-01-01

    Experimental conditions to permit rapid monitoring of soils, smears, and air dusts for transuranic (TRU) radionuclides under field conditions are described. The monitoring technique involves direct measurement of alpha emitters by alpha spectrometry using a large-area detector to identify and quantify the radionuclides present. The direct alpha spectrometry employs a circular gridded ionization chamber 35 cm in diameter which accommodates either a circular sample holder 25 cm in diameter or a rectangular one 20 by 25 cm (8 by 10 in.). Soils or settled dusts are finely ground, suspended in 30% ethanol, and sprayed onto a 25-cm stainless steel dish. Air dusts are collected with a high-volume sampler onto 20- by 25-cm membrane filters. Removable contamination is collected from surfaces onto a 20- by 25-cm filter using an 18-cm (7-in.) paint roller to hold the large filter in contact with the surface during sample collection. All three types of samples are then counted directly in the alpha spectrometer and no other sample preparation is necessary. Some results obtained are described

  7. Standardization of 241Am by digital coincidence counting, liquid scintillation counting and defined solid angle counting

    International Nuclear Information System (INIS)

    Balpardo, C.; Capoulat, M.E.; Rodrigues, D.; Arenillas, P.

    2010-01-01

    The nuclide 241 Am decays by alpha emission to 237 Np. Most of the decays (84.6%) populate the excited level of 237 Np with energy of 59.54 keV. Digital coincidence counting was applied to standardize a solution of 241 Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid scintillation counting using the logical sum of double coincidences in a TDCR array and defined solid angle counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.

  8. Laser based stripping system for measurement of the transverse emittance of H-beams at the CERN Linac4

    CERN Document Server

    Hofmann, T; Raich, U; Roncarolo, F; Cheymol, B

    2013-01-01

    The new LINAC4 at CERN will accelerate H- particles to 160 MeV and allow high brightness proton beam transfers to the Proton Synchrotron Booster, via a charge-exchange injection scheme. This paper describes the conceptual design of a laser system proposed for transverse profile and emittance measurements based on photon detachment of electrons from the H- ions. The binding energy of the outer electron is only 0.75 eV and can easily be stripped with a laser beam. Measuring the electron signal as function of the laser position allows the transverse beam profile to be reconstructed. A downstream dipole can also be used to separate the laser neutralized H0 atoms from the main H- beam. By imaging these H0 atoms as a function of laser position the transverse emittance can be reconstructed in the same way as in traditional slit-and-grid systems. By properly dimensioning the laser power and spot size, this method results in negligible beam losses and is therefore non-destructive. In addition, the absence of material ...

  9. Effects of internally deposited alpha emitters

    International Nuclear Information System (INIS)

    Rundo, J.; Schlenker, R.A.; Stebbings, J.H.

    1985-01-01

    This study seeks to identify and quantify the human health effects of occupational exposures to radium, use the health effects data from the radium study to predict responses to other alpha-emitting and/or bone-seeking radionuclides at occupational exposure levels and above, and predict the effects of these radionuclides, specifically environmental radium and its daughters, at nonoccupational exposure levels. 14 refs

  10. Radon Progenies as a Source of Gross Alpha-beta Activities in Drinking Water in Vinaninkarena, Antsirabe-Madagascar

    International Nuclear Information System (INIS)

    Raoelina Andriambololona; Rabesiranana, N.; Rasolonirina, M.; Rakotomanga, H.

    2004-01-01

    The village of Vinaninkarena, Antsirabe, Madagascar is located in a high radioactivity area. With the aim of assessing the health impact of radioactivity pollution, a survey was conducted around an abandoned radium mining. Waters from 24 sampling points, including 5 wells and 13 springs were sampled. The water radioactivity was measured using a portable Triathler LSC, model 425-034 from Hidex Turku. Each sample is counted more than 3 times: less than 2h after sampling, 4h to few days and more than 3 weeks after when 226 Ra attains equilibrium with 222 Rn and its short-lived daughters. Combination of water non miscible, radon extractive LS cocktail and water miscible one is used to reveal contribution of radium, radon and its short lived progenies to the gross alpha-beta activities. Maximum activity values found are : 3.6±0.3 Bq.L -1 for 226 Ra, 554±9 Bq.L -1 for the excess of radon, and 408±8 Bq.L -1 for the excess of radon progenies. Based on these data, a daily consumption of 2 L of these waters by a standard person would produce an annual 226 Ra ingestion well above the annual intake limit for 226 Ra. Moreover, the increasing gross alpha-beta activity resulting from radon progenies raises the issue of health effects. The potential for rapid spring-to-mouth delivery, which is frequent in rural area, may expose the water consumer to the short-lived alpha particle emitters.

  11. New development of EPICS based data acquisition system for H-Alpha diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Taegu, E-mail: glory@nfri.re.kr; Lee, Woongryol; Son, Souhun; Park, Jinseop

    2015-10-15

    Highlights: • The H-Alpha DAQ system was modified to measure the low current signal from the PMT. • We developed a new H-Alpha data acquisition system with a CPCI based digitizer. • We developed a signal conditioning box for converting the current to voltage. • The new signal condition box (SCB) has three input range level (400 nA, 1 μA and 2 μA). • It was successfully performed and stably operates more than the previous DAQ system. - Abstract: The H-Alpha diagnostic system has been developed to measure the line integrated intensity in the direction of toroidal and poloidal. The data acquisition (DAQ) system for H-Alpha diagnostics of the Korea Superconducting Tokamak Advanced Research (KSTAR) at the beginning of the first plasma in 2008 was developed with VME form factor digitizer in the Linux OS platform. The VME digitizer module of H-Alpha data acquisition system was modified to measure the low current signal from the photo-multiplier tubes (PMT). The input maximum current values of modified digitizer module are 400 nA and low current data is expressed as the value of the voltage between −10 V and +10 V. At first time, there was no problem to measure H-Alpha signal, but it could not measure the H-Alpha data signal as the KSTAR Plasma density increased. It exceeds digitizer input range, which means the H-Alpha signal is over 400 nA, so we should manually change the resistor on the digitizer board to measure the 400 nA over current. This is not easy to do and showed instability in the long time operation with high sampling data acquisition. In order to overcome these weak points, a new H-Alpha data acquisition system has been developed with a compact PCI (cPCI) based digitizer and a signal conditioning box for converting the current to voltage in the Linux OS platform. The new data acquisition system was developed based on Experimental Physics and Industrial Control System (EPICS) framework like other KSTAR diagnostics with standard framework (SFW

  12. Micro-electrodeposition techniques for the preparation of small actinide counting sources for ultra-high resolution alpha spectrometry by microcalorimetry

    International Nuclear Information System (INIS)

    Plionis, A.A.; Hastings, E.P.; LaMont, S.P.; Dry, D.E.; Bacrania, M.K.; Rabin, M.W.; Rim, J.H.

    2009-01-01

    Special considerations and techniques are desired for the preparation of small actinide counting sources. Counting sources have been prepared on metal disk substrates (planchets) with an active area of only 0.079 mm 2 . This represents a 93.75% reduction in deposition area from standard electrodeposition methods. The actinide distribution upon the smaller planchet must remain thin and uniform to allow alpha particle emissions to escape the counting source with a minimal amount of self-attenuation. This work describes the development of micro-electrodeposition methods and optimization of the technique with respect to deposition time and current density for various planchet sizes. (author)

  13. Standardization and estimation of gross alpha and beta activities for potable water samples in presence of TDS using TDCR based LSA (Hidex 300SL)

    International Nuclear Information System (INIS)

    Gupta, Anil; Lenka, P.; Sahoo, S.K.; Patra, A.C.; Jha, S.K.; Tripathi, R.M.

    2018-01-01

    Quality of water is important in environmental studies because of its daily use for human consumption and an important route of intake for various elements and radionuclides. Therefore radiological quality of drinking water must be ensured. The screening parameter to evaluate the radiological safety of potable water is by estimating gross alpha and gross beta activities with a limit of 0.5 Bq/l and 1 Bq/l respectively. These have been traditionally being done by radiochemical co-precipitation of alpha and beta emitters followed by counting by ZnS(Ag) counter for alpha and gas flow proportional counter for beta. Gross alpha estimation in water samples with high TDS by ZnS(Ag) is difficult and often leads to underestimation of result due to self-absorption of alpha within the residue. This study was carried out to standardize a method to provide rapid results by simultaneously estimating both gross alpha and gross beta activity in the presence of TDS with adequate sensitivity, minimum sample processing

  14. Source preparations for alpha and beta measurements

    Energy Technology Data Exchange (ETDEWEB)

    Holm, E. [Risoe National Lab., Roskilde (Denmark)

    2001-01-01

    Regarding alpha particle emitters subject for environmental studies, electrodeposition or co-precipitation as fluorides are the most common methods. For electro deposition stainless steel is generally used as cathode material but also other metals such as Ni, Ag, and Cu showed promising results. The use of other anode material than platinum, such as graphite should be investigated. For other purposes such as optimal resolution other more sophisticated methods are used but often resulting in poorer recovery. For beta particle emitters the type of detection system will decide the source preparation. Similar methods as for alpha particle emitters, electrodeposition or precipitation techniques can be used. Due to the continuous energy distribution of the beta pulse height distribution a high resolution is not required. Thicker sources from the precipitates or a stable isotopic carrier can be accepted but correction for absorption in the source must be done. (au)

  15. Real-time monitoring for alpha emitters in high-airflow environments

    International Nuclear Information System (INIS)

    Koster, J.E.; MacArthur, D.W.; Bounds, J.A.; Rawool-Sullivan, M.; Whitley, C.R.; Conaway, J.G.; Steadman, P.A.

    1996-01-01

    Key problems in detecting alpha contamination for site characterization and decontamination and decommissioning that remain to be solved include measurement of airborne contamination, material holdup within pipes, and leakage of material containers. These problems are very difficult using traditional alpha detectors and systems. The ionization detection method (long-range alpha detection of LRAD) offers a number of specific advantages for these environmental measurements. An LRAD system detects the air molecules ionized by alpha-emitting contamination rather than the alpha particles. Thus, LRAD-based detectors are not limited by the short range of alpha particles and can be used to detect contamination anywhere that air can penetrate. Extending this technology to large enclosures of long pipes requires a system optimized for large airflows. In this paper we will present designs and preliminary results for high-volume flow-through air monitors based on the LRAD technique. In addition, we will discuss the behavior of the monitors and their potential applications

  16. Coordinated soft X-ray and H-alpha observation of solar flares

    Science.gov (United States)

    Zarro, D. M.; Canfield, R. C.; Metcalf, T. R.; Lemen, J. R.

    1988-01-01

    Soft X-ray, Ca XIX, and H-alpha observations obtained for a set of four solar flares in the impulsive phase are analyzed. A blue asymmetry was observed in the coronal Ca XIX line during the soft-Xray rise phase in all of the events. A red asymmetry was observed simultaneously in chromospheric H-alpha at spatial locations associated with enhanced flare heating. It is shown that the impulsive phase momentum of upflowing soft X-ray plasma equalled that of the downflowing H-alpha plasma to within an order of magnitude. This supports the explosive chromospheric evaporation model of solar flares.

  17. Dust Attenuation and H(alpha) Star Formation Rates of Z Approx. 0.5 Galaxies

    Science.gov (United States)

    Ly, Chun; Malkan, Matthew A.; Kashikawa, Nobunari; Ota, Kazuaki; Shimasaku, Kazuhiro; Iye, Masanori; Currie, Thayne

    2012-01-01

    Using deep narrow-band and broad-band imaging, we identify 401 z approximately 0.40 and 249 z approximately 0.49 H-alpha line-emitting galaxies in the Subaru Deep Field. Compared to other H-alpha surveys at similar redshifts, our samples are unique since they probe lower H-alpha luminosities, are augmented with multi-wavelength (rest-frame 1000AA--1.5 microns) coverage, and a large fraction (20%) of our samples has already been spectroscopically confirmed. Our spectra allow us to measure the Balmer decrement for nearly 60 galaxies with H-beta detected above 5-sigma. The Balmer decrements indicate an average extinction of A(H-alpha)=0.7(uparrow){+1.4}_{-0.7} mag. We find that the Balmer decrement systematically increases with higher H-alpha luminosities and with larger stellar masses, in agreement with previous studies with sparser samples. We find that the SFRs estimated from modeling the spectral energy distribution (SED) is reliable---we derived an "intrinsic" H-alpha luminosity which is then reddened assuming the color excess from SED modeling. The SED-predicted H-alpha luminosity agrees with H-alpha narrow-band measurements over 3 dex (rms of 0.25 dex). We then use the SED SFRs to test different statistically-based dust corrections for H-alpha and find that adopting one magnitude of extinction is inappropriate: galaxies with lower luminosities are less reddened. We find that the luminosity-dependent dust correction of Hopkins et al. yields consistent results over 3 dex (rms of 0.3 dex). Our comparisons are only possible by assuming that stellar reddening is roughly half of nebular reddening. The strong correspondence argue that with SED modeling, we can derive reliable intrinsic SFRs even in the absence of H-alpha measurements at z approximately 0.5.

  18. Standardization of {sup 241}Am by digital coincidence counting, liquid scintillation counting and defined solid angle counting

    Energy Technology Data Exchange (ETDEWEB)

    Balpardo, C., E-mail: balpardo@cae.cnea.gov.a [Laboratorio de Metrologia de Radioisotopos, CNEA, Buenos Aires (Argentina); Capoulat, M.E.; Rodrigues, D.; Arenillas, P. [Laboratorio de Metrologia de Radioisotopos, CNEA, Buenos Aires (Argentina)

    2010-07-15

    The nuclide {sup 241}Am decays by alpha emission to {sup 237}Np. Most of the decays (84.6%) populate the excited level of {sup 237}Np with energy of 59.54 keV. Digital coincidence counting was applied to standardize a solution of {sup 241}Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid scintillation counting using the logical sum of double coincidences in a TDCR array and defined solid angle counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.

  19. Release of alpha emitters into the environment by Nuclear Industries of Brazil in Resende, RJ

    International Nuclear Information System (INIS)

    Pereira, Wagner S.; Kelecom, Alphonse; Santos, Rodney; Santos, Maisa F.M.; Torres, Vinicius R.M.; Rodrigues, Jéssica J.S.; Universidade Veiga de Almeida; Universidade Federal Fluminense

    2017-01-01

    The Nuclear Industries of Brazil operates in the field of nuclear energy and has a monopoly on mining and manufacturing the nuclear fuel element in Brazil. The Nuclear Fuel Factory is also responsible for the reconversion process, the manufacture of the pellets and the assembly of the fuel element. Once there is a possibility of particulate material generation during the reconversion processes and the manufacture of pellets, a method of collective protection of the worker was established, which includes a system of air exhaustion of the factory area, with the capacity to renew the indoor air six times per hour. As a control measure, there is a system of automatic detection of the release of radionuclides in the chimney that monitors and calculates the released values. Through the dose calculation model established by the National Commission for Nuclear Energy the release limit is fixed at 1.2∙ 10"7Bq.y"-"1 of alpha emitters by FCN. The present work aims to evaluate the alpha radionuclides released by FCN, in terms of total release (Bq) and Activity Concentration (AC, mBq∙m"-"3). In 2016 it was released 4.14∙10"6Bq.y"-"1, which means an average of 3.45∙10"5Bq.month"-"1. The largest mean for AC was 4.03 mBq∙m"-"3. The release data was almost an order of magnitude lower than the annual release limit, proving the suitability of the atmospheric effluents to the licensing requirements. The largest magnitudes of the two variables (AC and release) were observed in August while the smallest ones, in January. (author)

  20. Release of alpha emitters into the environment by Nuclear Industries of Brazil in Resende, RJ

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Wagner S.; Kelecom, Alphonse; Santos, Rodney; Santos, Maisa F.M.; Torres, Vinicius R.M.; Rodrigues, Jéssica J.S., E-mail: comap@inb.gov.br, E-mail: pereiraws@gmail.com, E-mail: lararapls@hotmail.com [Indústrias Nucleares do Brasil (COMAP.N/FCN/INB), Resende RJ (Brazil). Fábrica de Combustível Nuclear. Coordenação de Meio Ambiente e Proteção Radiológica Ambiental; Universidade Veiga de Almeida (UVA), Rio de Janeiro, RJ (Brazil); Universidade Federal Fluminense (LARARA-PLS/UFF), Niterói, RJ (Brazil). Laboratório de Radiobiologia e Radiometria

    2017-07-01

    The Nuclear Industries of Brazil operates in the field of nuclear energy and has a monopoly on mining and manufacturing the nuclear fuel element in Brazil. The Nuclear Fuel Factory is also responsible for the reconversion process, the manufacture of the pellets and the assembly of the fuel element. Once there is a possibility of particulate material generation during the reconversion processes and the manufacture of pellets, a method of collective protection of the worker was established, which includes a system of air exhaustion of the factory area, with the capacity to renew the indoor air six times per hour. As a control measure, there is a system of automatic detection of the release of radionuclides in the chimney that monitors and calculates the released values. Through the dose calculation model established by the National Commission for Nuclear Energy the release limit is fixed at 1.2∙ 10{sup 7}Bq.y{sup -1} of alpha emitters by FCN. The present work aims to evaluate the alpha radionuclides released by FCN, in terms of total release (Bq) and Activity Concentration (AC, mBq∙m{sup -3}). In 2016 it was released 4.14∙10{sup 6}Bq.y{sup -1}, which means an average of 3.45∙10{sup 5}Bq.month{sup -1}. The largest mean for AC was 4.03 mBq∙m{sup -3}. The release data was almost an order of magnitude lower than the annual release limit, proving the suitability of the atmospheric effluents to the licensing requirements. The largest magnitudes of the two variables (AC and release) were observed in August while the smallest ones, in January. (author)

  1. The Ca II resonance lines in M dwarf stars without H-alpha emission

    Energy Technology Data Exchange (ETDEWEB)

    Giampapa, M.S.; Cram, L.E.; Wild, W.J. (National Solar Observatory, Tucson, AZ (USA) Sydney Univ. (Australia) Arizona Univ., Tucson (USA))

    1989-10-01

    Spectra of the Ca II H and K lines in a sample of 31 M dwarf stars without H-alpha emission are used to calculate chromospheric K line radiative losses, F(k), and to study the joint response of Ca II K and H-alpha to chromospheric heating in dwarf M stars. It is suggested that the poor correlation found in the equivalent width - log F(K) diagram may be due either to radial segregation of the H-alpha and K line forming regions or to lateral inhomogeneities in the chromospheres. The results confirm the existence of dM stars with weak H-alpha absorption and K line emission only slightly weaker than that of the dMe stars, and show that dM stars with weak H-alpha but kinematics and metallicities representative of the young disk population belong to a class characterized by a comparatively high degree of chromospheric activity. 32 refs.

  2. Optimization of Counting Times, Figure of Merit and Mass Thickness for Low-background Alpha/beta Proportional Counter in Sea Water

    International Nuclear Information System (INIS)

    Pakkong, Pannee; Wongsanit, Sarinya; Tumnoi, Yutthana; Udomsomporn, Suchin

    2011-06-01

    Full text: The determination of gross alpha and beta activity in environmental aqueous samples can be done by using a low-background alpha/beta proportional counter with multiple detector type (Bert hold LB770). The co precipitate sea water samples were considered for optimal regime of counting time, the minimum detectable activity (MDA), mass thickness of samples (mg/cm-2) and figure of merit (FOM). The result showed that the MDA of the measurements were estimated to be 0.07 Bq/l for gross alpha and 0.05 Bq/l for gross beta at counting time of 100 and 200 minute, respectively. The thickness of samples prepared by coprecipitation technique indicated more parochial range when compared to evaporation to dryness method. In addition, the samples were in the suitable range that can be corrected by the previous self-absorption correction factor (F a ) as 0.0003w 2 -0.0414 w+1.692; where F a is the self-absorption correction factor and w is the weight of the final precipitate in milligrams

  3. Set of counts by scintillations for atmospheric samplings

    International Nuclear Information System (INIS)

    Appriou, D.; Doury, A.

    1962-01-01

    The author reports the development of a scintillation-based counting assembly with the following characteristics: a photo-multiplier with a wide photo-cathode, a thin plastic scintillator for the counting of beta + alpha (and possibility of mounting an alpha scintillator), a relatively small own motion with respect to activities to be counted, a weakly varying efficiency. The authors discuss the counting objective, present equipment tests (counter, proportional amplifier and pre-amplifier, input drawer). They describe the apparatus operation, discuss the selection of scintillators, report the study of the own movement (electron-based background noise, total background noise, background noise reduction), discuss counts (influence of the external source, sensitivity to alpha radiations, counting homogeneity, minimum detectable activity) and efficiencies

  4. Generator-produced alpha-emitters

    International Nuclear Information System (INIS)

    Mirzadeh, S.

    1996-01-01

    This review briefly describes the nuclear characteristics and production parameters for 7.2-h 211 At, 60.6-min 212 Bi, 45.6-min 213 Bi, 11-d 233 Ra, and 20-h 255 Fm. These a-emitting radioisotopes are the subject of current interest for a-particle-mediated radioimmunotherapy

  5. Gamma-spectrometric and total alpha-beta counting methods for radioactivity analysis of deuterium depleted water

    International Nuclear Information System (INIS)

    Ferdes, Ov. S.; Mladin, C.; Vladu, Mihaela; Bulubasa, G.; Bidica, N.

    2008-01-01

    According to national regulations, as well as to the EU directive on the quality of drinking water, the radionuclide concentrations represent some of the drinking water quality parameters. Among the most important radioactivity content parameters are: the total alpha and total beta concentration (Bq/l); K-40 content, and the gamma-nuclides volume activities. The paper presents the measuring methods for low-level total alpha and/or beta counting of volume samples, as well as the high-resolution gamma-ray spectrometric method used to measure the volume activity of nuclides in drinking water. These methods are applied to monitor the radioactivity content and quality of the QLARIVIA brand of Deuterium depleted water (DDW). There are discussed the performances of these applied methods as well as some preliminary results. (authors)

  6. Technical Basis for the Use of Alpha Absorption Corrections on RCF Gross Alpha Data

    International Nuclear Information System (INIS)

    Ceffalo, G.M.

    1999-01-01

    This document provides the supporting data and rationale for making absorption corrections to gross alpha data to correct alpha data for loss due to absorption in the sample matrix. For some time there has been concern that the gross alpha data produced by the Environmental Restoration Contractor Radiological Counting Facility, particularly gross alpha analysis on soils, has been biased toward low results, as no correction for self-absorption was applied to the counting data. The process was investigated, and a new methodology for alpha self-absorption has been developed

  7. Treatment of carcinoma in situ of the urinary bladder with an alpha-emitter immunoconjugate targeting the epidermal growth factor receptor: a pilot study.

    Science.gov (United States)

    Autenrieth, Michael E; Seidl, Christof; Bruchertseifer, Frank; Horn, Thomas; Kurtz, Florian; Feuerecker, Benedikt; D'Alessandria, Calogero; Pfob, Christian; Nekolla, Stephan; Apostolidis, Christos; Mirzadeh, Saed; Gschwend, Jürgen E; Schwaiger, Markus; Scheidhauer, Klemens; Morgenstern, Alfred

    2018-07-01

    Patients with carcinoma in situ (CIS) of the bladder refractory to bacillus Calmette-Guérin (BCG) treatment are usually treated with cystectomy. Therefore, new treatment options with preservation of the urinary bladder are needed. The objective of the study was to investigate the feasibility, safety and efficacy of a novel targeted alpha-emitter immunotherapy for CIS after BCG treatment failure. A pilot study was conducted in 12 patients (age range 64-86 years, ten men, two women) with biopsy-proven CIS of the bladder refractory to BCG treatment. The patients were treated intravesically with a single instillation (one patient was treated twice) of the alpha-emitter 213 Bi coupled to an anti-EGFR antibody (366-821 MBq). The primary aims of the study were to determine the feasibility of treatment with the 213 Bi-immunoconjugate and evaluation of adverse effects. Therapeutic efficacy was monitored by histological mapping of the urinary bladder 8 weeks after treatment and at different time points thereafter. The study proved that intravesical instillation of the 213 Bi-immunoconjugate targeting EGFR is feasible. No adverse effects were observed and all blood and urine parameters determined remained in their normal ranges. Therapeutic efficacy was considered satisfactory, in that three of the 12 patients showed no signs of CIS 44, 30 and 3 months after treatment. Intravesical instillation of 213 Bi-anti-EGFR monoclonal antibody was well tolerated and showed therapeutic efficacy. Repeated instillation and/or instillation of higher activities of the 213 Bi-immunoconjugate might lead to better therapeutic outcomes. A phase I clinical trial is planned.

  8. Preparation and preclinical evaluation of {sup 211}At-labelled compounds for {alpha}-particle radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, R H

    1994-12-31

    The interest for {alpha}-particle emitters in internal radiotherapy is increasing due to improved conjugation chemistry. Experimental work has concentrated on {sup 211}At and {sup 212}Bi since these to nuclides have radiochemical and physical properties suitable for medical application. In this report it is demonstrated that biologically active {sup 211}At-labelled compounds can be prepared within a relatively short time allowing utilization of this 7.2 h {alpha}-particle. It is further shown that {sup 211}At-TP-3 treatment of human osteosarcoma in vitro gives promising therapeutic ratios. 76 refs., 5 figs., 3 tabs.

  9. Carbon stars with alpha-C:H emission

    Science.gov (United States)

    Gerbault, Florence; Goebel, John H.

    1989-01-01

    Many carbon stars in the IRS low resolution spectra (LRS) catalog were found which display emission spectra that compare favorable with the absorption spectrum of alpha-C:H. These stars have largely been classified as 4X in the LRS which has led to their interpretation by others in terms of displaying a mixture of the UIRF's 8.6 micron band and SiC at 11.5 microns. It was also found that many of these stars have a spectral upturn at 20+ microns which resembles the MgS band seen in carbon stars and planetary nebulae. It was concluded that this group of carbon stars will evolve into planetary nebulae like NGC 7027 and IC 418. In the presence of hard ultraviolet radiation the UIRF's will light up and be displayed as narrow emission bands on top of the broad alpha-C:H emission bands.

  10. Evaluation of surface contamination due to alpha using large area contamination monitors

    International Nuclear Information System (INIS)

    Raghavayya, M.

    1998-01-01

    Radioactive contamination at work places is evaluated routinely using either the swipe sampling technique or a contamination monitor. Commercially available alpha probes used for the purpose are usually circular and have a face diameter of 50 or 100 mm. Square faced probes are also available. A thin aluminized mylar membrane of thickness 0.45 to 0.9 mg.cm -2 is used to screen the phosphor in the alpha probe to protect it from external light. The membrane cuts off more alphas from low energy emitters than from higher energy alpha emitters. Moreover the response of the detector for alphas originating at all points under the detector face is not uniform, especially when the large area alpha monitors are used. These factors can introduce errors as high as 40% into the measurements. This paper aims to quantify these errors and describe a procedure to overcome the limitations. (author)

  11. Alpha-tocopherol transfer factor (aTTF) from rat liver mediates the transfer of d-alpha-[3H]-tocopherol from liposomes to human erythrocyte ghosts and exhibits saturation kinetics

    International Nuclear Information System (INIS)

    Verdon, C.P.; Blumberg, J.B.

    1986-01-01

    aTTF was observed to transfer d-alpha-[ 3 H]-tocopherol ( 3 HaT) from egg lecithin liposomes to human erythrocyte ghosts (EG). aTTF may be associated with the 32,000-35,000 MW alpha-Tocopherol Binding Protein previously described to transfer 3 HaT from liposomes to rat liver microsomes and mitochondria prepared by ammonium sulfate precipitation of rat liver cytosol followed by dialysis against 50 mM TRIS-HCl/1 mM EDTA buffer, pH 7.4. Assay for aTTF activity consisted of incubating liposomal 3 HaT and EG in the presence of aTTF or buffer blank for various time periods at 37 0 C, then counting the resulting radioactivity in washed EG after pelleting by centrifugation. Liposomes were prelabeled-with non-exchangable glycerol-[ 14 C]-trioleate to correct for liposomes adhering to pelleted EG. Greater than 50% of the tritium found with the EG pellet was recovered by HPLC as 3 HaT. aTTF activity increased with increasing liposomal 3 HaT concentration before reaching a plateau. aTTF activity was similarly saturated by increasing EG concentrations. The same assay conditions with buffer blank along resulted in negligible transfer activity

  12. COMPARING H{alpha} AND H I SURVEYS AS MEANS TO A COMPLETE LOCAL GALAXY CATALOG IN THE ADVANCED LIGO/VIRGO ERA

    Energy Technology Data Exchange (ETDEWEB)

    Metzger, Brian D. [Department of Astrophysical Sciences, Peyton Hall, Princeton University, Princeton, NJ 08542 (United States); Kaplan, David L. [Physics Department, University of Wisconsin-Milwaukee, Milwaukee, WI 53211 (United States); Berger, Edo, E-mail: bmetzger@astro.princeton.edu, E-mail: kaplan@uwm.edu, E-mail: eberger@cfa.harvard.edu [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States)

    2013-02-20

    Identifying the electromagnetic counterparts of gravitational wave (GW) sources detected by upcoming networks of advanced ground-based interferometers will be challenging, due in part to the large number of unrelated astrophysical transients within the {approx}10-100 deg{sup 2} sky localizations. A potential way to greatly reduce the number of such false positives is to limit detailed follow-up to only those candidates near galaxies within the GW sensitivity range of {approx}200 Mpc for binary neutron star mergers. Such a strategy is currently hindered by the fact that galaxy catalogs are grossly incomplete within this volume. Here, we compare two methods for completing the local galaxy catalog: (1) a narrowband H{alpha} imaging survey and (2) an H I emission line radio survey. Using H{alpha} fluxes, stellar masses (M {sub *}), and star formation rates (SFRs) from galaxies in the Sloan Digital Sky Survey (SDSS), combined with H I data from the GALEX Arecibo SDSS Survey and the Herschel Reference Survey, we estimate that an H{alpha} survey with a luminosity sensitivity of L {sub H{alpha}} = 10{sup 40} erg s{sup -1} at 200 Mpc could achieve a completeness of f {sup H{alpha}} {sub SFR} Almost-Equal-To 75% with respect to total SFR, but only f{sub M* Star-Operator }{sup H{alpha}} approx. 33% with respect to M {sub *} (due to lack of sensitivity to early-type galaxies). These numbers are significantly lower than those achieved by an idealized spectroscopic survey due to the loss of H{alpha} flux resulting from resolving out nearby galaxies and the inability to correct for the underlying stellar continuum. An H I survey with sensitivity similar to the proposed WALLABY survey on ASKAP could achieve f{sub SFR}{sup H{sub I}} Almost-Equal-To 80% and f{sub M Star-Operator }{sup H{sub I}} Almost-Equal-To 50%, somewhat higher than that of the H{alpha} survey. Finally, both H{alpha} and H I surveys should achieve {approx}> 50% completeness with respect to the host galaxies of

  13. Digital readout alpha survey instrument

    International Nuclear Information System (INIS)

    Jacobs, M.E.

    1976-01-01

    A prototype solid-state digital readout alpha particle survey instrument has been designed and constructed. The meter incorporates a Ludlum alpha scintillator as a detector, digital logic circuits for control and timing, and a Digilin counting module with reflective liquid crystal display. The device is used to monitor alpha radiation from a surface. Sample counts are totalized over 10-second intervals and displayed digitally in counts per minute up to 19,999. Tests over source samples with counts to 15,600 cpm have shown the device to be rapid, versatile and accurate. The instrument can be fabricated in one man-week and requires about $835 in material costs. A complete set of drawings is included

  14. Asymmetrical field emitter

    Science.gov (United States)

    Fleming, J.G.; Smith, B.K.

    1995-10-10

    A method is disclosed for providing a field emitter with an asymmetrical emitter structure having a very sharp tip in close proximity to its gate. One preferred embodiment of the present invention includes an asymmetrical emitter and a gate. The emitter having a tip and a side is coupled to a substrate. The gate is connected to a step in the substrate. The step has a top surface and a side wall that is substantially parallel to the side of the emitter. The tip of the emitter is in close proximity to the gate. The emitter is at an emitter potential, and the gate is at a gate potential such that with the two potentials at appropriate values, electrons are emitted from the emitter. In one embodiment, the gate is separated from the emitter by an oxide layer, and the emitter is etched anisotropically to form its tip and its asymmetrical structure. 17 figs.

  15. Emittance preservation

    Energy Technology Data Exchange (ETDEWEB)

    Kain, V; Arduini, G; Goddard, B; Holzer, B J; Jowett, J M; Meddahi, M; Mertens, T; Roncarolo, F; Schaumann, M; Versteegen, R; Wenninger, J [European Organization for Nuclear Research, Geneva (Switzerland)

    2012-07-01

    Emittance measurements during the LHC proton run 2011 indicated a blow-up of 20 % to 30 % from LHC injection to collisions. This presentation will show the emittance preservation throughout the different parts of the LHC cycle and discuss the current limitations on emittance determination. An overview of emittance preservation through the injector complex as function of bunch intensity will also be given. Possible sources for the observed blow-up and required tests in 2012 will be presented. Possible improvements of emittance diagnostics and analysis tools for 2012 will be shown.

  16. Remote Optical Detection of Alpha Radiation

    International Nuclear Information System (INIS)

    Sand, J.; Hannuksela, V.; Toivonen, J.; Ihantola, S.; Peraejaervi, K.; Toivonen, H.

    2010-01-01

    Alpha emitting radiation sources are typically hard to detect with conventional detectors due to the short range of alpha particles in the air. However, previous studies have shown that remote detection of alpha radiation is possible by measuring the ionization-induced fluorescence of air molecules. The alpha-induced ultraviolet (UV) light is mainly emitted by molecular nitrogen and its fluorescence properties are well known. The benefit of this method is the long range of UV photons in the air. Secondly, the detection is possible also under a strong beta and gamma radiation backgrounds as they do not cause localized molecular excitation. In this work, the optical detection was studied using two different detection schemes; spectral separation of fluorescence from the background lighting and coincidence detection of UV photons originating from a single radiative decay event. Our spectrally integrated measurements have shown that one alpha decay event yields up to 400 fluorescence photons in the air and all these UV photons are induced in a 5 ns time-window. On the other hand, the probability of a background coincidence event in 5 ns scale is very rare compared to the number of background photons. This information can be applied in fluorescence coincidence filtering to discriminate the alpha radiation initiated fluorescence signal from much more intense background lighting. A device called HAUVA (Handheld Alpha UV Application) was built during this work for demonstration purposes. HAUVA utilizes spectral filtering and it is designed to detect alpha emitters from a distance of about 40 cm. Using specially selected room lighting, the device is able to separate 1 kBq alpha emitter from the background lighting with 1 second integration time. (author)

  17. A study of excess H-alpha emission in chromospherically active M dwarf

    International Nuclear Information System (INIS)

    Young, A.; Skumanich, A.; Stauffer, J.R.; Harlan, E.; Bopp, B.W.

    1989-01-01

    Spectroscopic observations from three observatories are combined to study the properties of the excess H-alpha emission which characterizes the most chromospherically active subset of the M dwarf stars, known as the dMe stars. It is demonstrated that the excess H-alpha luminosity from these stars is a monotonically decreasing function of their (R-I) color, and evidence is presented which suggests that the product of the mean surface brightness and the mean filling factor of the emissive regions is essentially constant with color. Another significant result of the study is a linear correlation between the excess luminosity in H-alpha and the coronal X-ray luminosity. 39 refs

  18. Triple Layer Antireflection Design Concept for the Front Side of c-Si Heterojunction Solar Cell Based on the Antireflective Effect of nc-3C-SiC:H Emitter Layer

    Directory of Open Access Journals (Sweden)

    Erick Omondi Ateto

    2016-01-01

    Full Text Available We investigated the antireflective (AR effect of hydrogenated nanocrystalline cubic silicon carbide (nc-3C-SiC:H emitter and its application in the triple layer AR design for the front side of silicon heterojunction (SHJ solar cell. We found that the nc-3C-SiC:H emitter can serve both as an emitter and antireflective coating for SHJ solar cell, which enables us to realize the triple AR design by adding one additional dielectric layer to normally used SHJ structure with a transparent conductive oxide (TCO and an emitter layer. The optimized SHJ structure with the triple layer AR coating (LiF/ITO/nc-3C-SiC:H exhibit a short circuit current density (Jsc of 38.65 mA/cm2 and lower reflectivity of about 3.42% at wavelength range of 300 nm–1000 nm.

  19. Deep rest-frame far-UV spectroscopy of the giant Lyman α emitter 'Himiko'

    DEFF Research Database (Denmark)

    Zabl, J.; Nørgaard-Nielsen, Hans Ulrik; Fynbo, J. P. U.

    2015-01-01

    We present deep 10 h VLT/XSHOOTER spectroscopy for an extraordinarily luminous and extended Ly alpha emitter at z = 6.595 referred to asHimiko and first discussed by Ouchi et al., with the purpose of constraining the mechanisms powering its strong emission. Complementary to the spectrum, we discuss...... near-infrared imaging data from the CANDELS survey. We find neither for He II nor any metal line a significant excess, with 3 σ upper limits of 6.8, 3.1, and 5.8 x 10-18 erg s-1 cm-2 for C IV λ 1549, He II λ 1640, C III] λ 1909, respectively, assuming apertures with 200 km s-1 widths and offset by -250...

  20. Alpha-in-air monitor for continuous monitoring based on alpha to beta ratio

    International Nuclear Information System (INIS)

    Somayaji, K.S.; Venkataramani, R.; Swaminathan, N.; Pushparaja

    1997-01-01

    Measurement of long-lived alpha activity collected on a filter paper in continuous air monitoring of ambient working environment is difficult due to interference from much larger concentrations of short-lived alpha emitting daughter products of 222 Rn and 220 Rn. However, the ratio between the natural alpha and beta activity is approximately constant and this constancy of the ratio is used to discriminate against short-lived natural radioactivity in continuous air monitoring. Detection system was specially designed for the purpose of simultaneous counting of alpha and beta activity deposited on the filter paper during continuous monitoring. The activity ratios were calculated and plotted against the monitoring duration up to about six hours. Monitoring was carried out in three facilities with different ventilation conditions. Presence of any long-lived alpha contamination on the filter paper results in increase in the alpha to beta ratio. Long-lived 239 Pu contamination of about 16 DAC.h could be detected after about 45 minutes of commencement of the sampling. The experimental results using prototype units have shown that the approach of using alpha to beta activity ratio method to detect long-lived alpha activity in the presence of short-lived natural activity is satisfactory. (author)

  1. Local Control of Lung Derived Tumors by Diffusing Alpha-Emitting Atoms Released From Intratumoral Wires Loaded With Radium-224

    International Nuclear Information System (INIS)

    Cooks, Tomer; Schmidt, Michael; Bittan, Hadas; Lazarov, Elinor; Arazi, Lior; Kelson, Itzhak; Keisari, Yona

    2009-01-01

    Purpose: Diffusing alpha-emitters radiation therapy (DART) is a new form of brachytherapy enabling the treatment of solid tumors with alpha radiation. The present study examines the antitumoral effects resulting from the release of alpha emitting radioisotopes into solid lung carcinoma (LL2, A427, and NCI-H520). Methods and Materials: An in vitro setup tested the dose-dependent killing of tumor cells exposed to alpha particles. In in vivo studies, radioactive wires (0.3 mm diameter, 5 mm long) with 224 Ra activities in the range of 21-38 kBq were inserted into LL/2 tumors in C57BL/6 mice and into human-derived A427 or NCI-H520 tumors in athymic mice. The efficacy of the short-lived daughters of 224 Ra to produce tumor growth retardation and prolong life was assessed, and the spread of radioisotopes inside tumors was measured using autoradiography. Results: The insertion of a single DART wire into the center of 6- to 7-mm tumors had a pronounced retardation effect on tumor growth, leading to a significant inhibition of 49% (LL2) and 93% (A427) in tumor development and prolongations of 48% (LL2) in life expectancy. In the human model, more than 80% of the treated tumors disappeared or shrunk. Autoradiographic analysis of the treated sectioned tissue revealed the intratumoral distribution of the radioisotopes, and histological analysis showed corresponding areas of necrosis. In vitro experiments demonstrated a dose-dependent killing of tumors cells exposed to alpha particles. Conclusions: Short-lived diffusing alpha-emitters produced tumor growth retardation and increased survival in mice bearing lung tumor implants. These results justify further investigations with improved dose distributions.

  2. About the reactions sup 3 H(alpha,gamma) sup 7 Li and sup 3 He(alpha,gamma) sup 7 Be

    CERN Document Server

    Loeffler, W

    1993-01-01

    In this article the current experimental and theoretical status of the radiative alpha capture reactions sup 3 H(alpha,gamma) sup 7 Li and sup 3 He(alpha,gamma) sup 7 Be and their relations to primordial nucleosynthesis and the solar neutrino problem are reviewed. (author)

  3. CANDIDATES OF H{alpha} EMITTING REGIONS IN THE MAGELLANIC STREAM IV CLOUD

    Energy Technology Data Exchange (ETDEWEB)

    Yagi, Masafumi; Komiyama, Yutaka [Optical and Infrared Astronomy Division, National Astronomical Observatory of Japan, 2-21-1 Osawa, Mitaka, Tokyo 181-8588 (Japan); Yoshida, Michitoshi, E-mail: YAGI.Masafumi@nao.ac.jp [Hiroshima Astrophysical Science Center, Hiroshima University, 1-3-1 Kagamiyama, Higashi-Hiroshima, Hiroshima 739-8526 (Japan)

    2012-04-10

    From H{alpha} narrowband observations, we identified three H{alpha} emitting regions in the direction of Magellanic Stream IV (MS IV). They consist of three parallel filaments of 2 arcmin width and 6-30 arcmin length at 12 arcmin intervals. Their mean surface brightness (SB) is {approx}2 Multiplication-Sign 10{sup -18} erg s{sup -1} cm{sup -2} arcsec{sup -2}. Because of their low SB, the regions were not detected in previous H{alpha} surveys. In the H I map, the position of the filaments overlap MS, suggesting that they are parts of the MS, but there also exists a local H I structure. If the filaments are associated with the MS, the sizes are 30 pc Multiplication-Sign 100-500 pc. The filaments lie at the leading edge of a downstream cloud, which supports shock heating and its propagation (shock cascade) model for the ionizing source. If they are local objects, on the other hand, Fossil Stroemgren Trails of more than two stars is a possible interpretation, and the sizes would be 0.1 pc Multiplication-Sign 0.3-1.5 pc at 180 pc distance. The positional information of the H{alpha} filaments presented in this Letter enables future spectroscopic observations to clarify their nature.

  4. Standardization of Ga-68 by coincidence measurements, liquid scintillation counting and 4πγ counting

    International Nuclear Information System (INIS)

    Roteta, Miguel; Peyres, Virginia; Rodríguez Barquero, Leonor; García-Toraño, Eduardo; Arenillas, Pablo; Balpardo, Christian; Rodrígues, Darío; Llovera, Roberto

    2012-01-01

    The radionuclide 68 Ga is one of the few positron emitters that can be prepared in-house without the use of a cyclotron. It disintegrates to the ground state of 68 Zn partially by positron emission (89.1%) with a maximum energy of 1899.1 keV, and partially by electron capture (10.9%). This nuclide has been standardized in the frame of a cooperation project between the Radionuclide Metrology laboratories from CIEMAT (Spain) and CNEA (Argentina). Measurements involved several techniques: 4πβ−γ coincidences, integral gamma counting and Liquid Scintillation Counting using the triple to double coincidence ratio and the CIEMAT/NIST methods. Given the short half-life of the radionuclide assayed, a direct comparison between results from both laboratories was excluded and a comparison of experimental efficiencies of similar NaI detectors was used instead. - Highlights: ► We standardized the positron emitter Ga-68 in a bilateral cooperation. ► We used several techniques, as coincidence, integral gamma and liquid scintillation. ► An efficiency comparison replaced a direct comparison of reference materials.

  5. The average number of alpha-particle hits to the cell nucleus required to eradicate a tumour cell population

    International Nuclear Information System (INIS)

    Roeske, John C; Stinchcomb, Thomas G

    2006-01-01

    Alpha-particle emitters are currently being considered for the treatment of micrometastatic disease. Based on in vitro studies, it has been speculated that only a few alpha-particle hits to the cell nucleus are considered lethal. However, such estimates do not consider the stochastic variations in the number of alpha-particle hits, energy deposited, or in the cell survival process itself. Using a tumour control probability (TCP) model for alpha-particle emitters, we derive an estimate of the average number of hits to the cell nucleus required to provide a high probability of eradicating a tumour cell population. In simulation studies, our results demonstrate that the average number of hits required to achieve a 90% TCP for 10 4 clonogenic cells ranges from 18 to 108. Those cells that have large cell nuclei, high radiosensitivities and alpha-particle emissions occurring primarily in the nuclei tended to require more hits. As the clinical implementation of alpha-particle emitters is considered, this type of analysis may be useful in interpreting clinical results and in designing treatment strategies to achieve a favourable therapeutic outcome. (note)

  6. Human myometrial adrenergic receptors during pregnancy: identification of the alpha-adrenergic receptor by [3H] dihydroergocryptine binding

    International Nuclear Information System (INIS)

    Jacobs, M.M.; Hayashida, D.; Roberts, J.M.

    1985-01-01

    The radioactive alpha-adrenergic antagonist [ 3 H] dihydroergocryptine binds to particulate preparations of term pregnant human myometrium in a manner compatible with binding to the alpha-adrenergic receptor (alpha-receptor). [ 3 H] Dihydroergocryptine binds with high affinity (KD = 2 nmol/L and low capacity (receptor concentration = 100 fmol/mg of protein). Adrenergic agonists compete for [ 3 H] dihydroergocryptine binding sites stereo-selectively ([-]-norepinephrine is 100 times as potent as [+]-norepinephrine) and in a manner compatible with alpha-adrenergic potencies (epinephrine approximately equal to norepinephrine much greater than isoproterenol). Studies in which prazosin, an alpha 1-antagonist, and yohimbine, and alpha 2-antagonist, competed for [ 3 H] dihydroergocryptine binding sites in human myometrium indicated that approximately 70% are alpha 2-receptors and that 30% are alpha 1-receptors. [ 3 H] dihydroergocryptine binding to human myometrial membrane particulate provides an important tool with which to study the molecular mechanisms of uterine alpha-adrenergic response

  7. Radiolytic oxidation of UO{sub 2} pellets doped with alpha-emitters ({sup 238/239}Pu)

    Energy Technology Data Exchange (ETDEWEB)

    Muzeau, B. [Commissariat a l' Energie Atomique, Rhone Valley Research Center DTCD/SECM/LMPA, BP 17 171, 30207 Bagnols-sur-Ceze Cedex (France); Jegou, C. [Commissariat a l' Energie Atomique, Rhone Valley Research Center DTCD/SECM/LMPA, BP 17 171, 30207 Bagnols-sur-Ceze Cedex (France)], E-mail: christophe.jegou@cea.fr; Delaunay, F. [Commissariat a l' Energie Atomique, Valduc Research Center, 21120 Is-sur-Tille (France); Broudic, V. [Commissariat a l' Energie Atomique, Rhone Valley Research Center DTCD/SECM/LMPA, BP 17 171, 30207 Bagnols-sur-Ceze Cedex (France); Brevet, A. [Commissariat a l' Energie Atomique, Valduc Research Center, 21120 Is-sur-Tille (France); Catalette, H. [Electricite de France, Les Renardieres Research Center, Route de Sens Ecuelles, 77250 Moret-sur-Loing (France); Simoni, E. [Institut de Physique Nucleaire, Bat. 100, 91406 Orsay Cedex (France); Corbel, C. [Laboratoire des Solides Irradies, UMR 7642-CNRS-CEA-Ecole Polytechnique, Ecole Polytechnique, 91128 Palaiseau Cedex (France)

    2009-01-07

    To assess the impact of alpha radiolysis of water on the oxidative dissolution of UO{sub 2} under anoxic conditions, two series of plutonium-doped samples (specific alpha activity 385 and 18 MBqg{sub UO{sub 2}}{sup -1}) were fabricated, characterized and leached in water of varying complexity (pure water, carbonated water, dissolved hydrogen). Given the very high reactivity of these samples in the presence of air and in order to minimize any prior surface oxidation, a strict experimental protocol was developed based on high-temperature annealing in Ar + 4% H{sub 2} with preleaching cycles. Failure to follow this protocol prevents absolute quantification of oxidation of the UO{sub 2} surface by water radiolysis in solutions. Preoxidation of the pellet surface can lead to uranium release in solution that is dependent on the alpha particle flux, revealing initial oxidation by radiolysis in air including potential traces of water. This makes difficult the accurate quantification of the radiolytic oxidation in water solutions. Controlling the initial surface condition of the samples finally allowed us to demonstrate that radiolytic oxidation in water-saturated media is governed by several threshold effects for which the main parameters are the sample alpha activity and the hydrogen concentration.

  8. Test chamber for alpha spectrometry

    Science.gov (United States)

    Larsen, Robert P.

    1977-01-01

    Alpha emitters for low-level radiochemical analysis by measurement of alpha spectra are positioned precisely with respect to the location of a surface-barrier detector by means of a chamber having a removable threaded planchet holder. A pedestal on the planchet holder holds a specimen in fixed engagement close to the detector. Insertion of the planchet holder establishes an O-ring seal that permits the chamber to be pumped to a desired vacuum. The detector is protected against accidental contact and resulting damage.

  9. Radial-velocity variations in Alpha Ori, Alpha Sco, and Alpha Her

    International Nuclear Information System (INIS)

    Smith, M.A.; Patten, B.M.; Goldberg, L.

    1989-01-01

    Radial-velocity observations of Alpha Ori, Alpha Sco A, and Alpha Her A are used to study radial-velocity periodicities in M supergiants. The data refer to several metallic lines in the H-alpha region and to H-alpha itself. It is shown that Alpha Ori and Alpha Sco A have cycle lengths of about 1 yr and semiamplitudes of 2 km/s. It is suggested that many semiregular red supergiant varibles such as Alpha Ori may be heading toward chaos. All three stars show short-term stochastic flucutations with an amplitude of 1-2 km/s. It is found that the long-term variability of H-alpha velocities may be a consequence of intermittent failed ejections. 58 refs

  10. Very bright, near-infrared single photon emitters in diamond

    Directory of Open Access Journals (Sweden)

    D. W. M. Lau

    2013-09-01

    Full Text Available We demonstrate activation of bright diamond single photon emitters in the near infrared range by thermal annealing alone, i.e., without ion implantation. The activation is crucially dependent on the annealing ambient. The activation of the single photon emitters is only observed when the sample is annealed in forming gas (4% H2 in Ar above temperatures of 1000 °C. By contrast, no emitters are activated by annealing in vacuum, oxygen, argon or deuterium. The emitters activated by annealing in forming gas exhibit very bright emission in the 730-760 nm wavelength range and have linewidths of ∼1.5-2.5 nm at room temperature.

  11. Liquid scintillation counting of 3H-thymidine incorporated into rat lens DNA

    International Nuclear Information System (INIS)

    Soederberg, P.G.; Lindstroem, B.

    1990-01-01

    DNA synthesis in the lens has previously been localized by autoradiography following incorporation of 3 H-thymidine. For the quantification of DNA synthesis in the lens, pooling of lenses and extraction of the DNA for liquid scintillation counting, has formerly been adapted. In the present investigation a method has been developed for the extraction of the unincorporated tracer from whole lenses after short time incubation in a medium containing 3 H-thymidine. The 3 H-thymidine incorporated into individual lenses was then detected by liquid scintillation counting after dissolution of the lenses. The sources of the variation in the method are evaluated. (author)

  12. Alpha/beta separation in liquid scintillation gel samples

    International Nuclear Information System (INIS)

    Grau Carles, A.; Grau Malonda, A.

    1994-01-01

    The pulse shape analysis commonly used in liquid scintillation alpha/beta separations is satisfactory for moderate quench levels. However, for gel samples, the alpha particle counting efficiency is never greater than 10%, and an optimum separation of the alpha component cannot be achieved when beta to alpha counting rate ratios are greater than 100. In such cases, it is better to use a spectrum analysis method for alpha/beta separation. ((orig.))

  13. Emittance measurements in Grumman 1 MeV beamline

    International Nuclear Information System (INIS)

    Debiak, T.; Gammel, G.; Melnychuk, S.

    1992-01-01

    The emittance of a 30 keV H - beam has been measured with an Allison type electrostatic analyser at two positions separated by 85 cm along the Grumman 1 MeV beamline LEBT at low currents (about 4 mA, no Cs 2 O additive in the source) and at higher currents (10-15 mA, with Cs 2 O additive in the source). No emittance growth was observed between the two positions, but, at the higher current level, the emittance was about 60% higher than at the low current level (Σ n ,rms = .0045 π cm-mrad vs. 0070 π cm-mrad). Argon was then introduced up to a partial pressure of 4x10 -5 torr, and the emittance decreased back to a range corresponding to that found at the lower currents. However, beam noise was observed at the downstream position, and there is evidence for a small amount of emittance growth (<20%) between the two positions

  14. Liquid scintillation: Sample preparation and counting atypical emissions

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    Liquid scintillation sample preparation has the most published information but the least amount of definitive technical direction because the chemical and physical nature of the samples from biological investigations varies widely. This chapter discusses the following related topics: Aqueous Samples; Tissue Solubilizers; Absorption of 14 CO 2 ; Sample Combustion Methods; Heterogeneous Systems; Sample Preparation Problems (colored samples, chemiluminescence, photoluminescence, static electricity); Counting Various Types of Emitters; Counting Atypical Emissions. 2 refs., 2 figs

  15. Rapid determination of gross alpha and beta activity in seafood utilizing microwave digestion and liquid scintillation counting

    International Nuclear Information System (INIS)

    Daniel Sas; Jiri Janda; Alena Tokarova

    2015-01-01

    This paper describes a method for rapid determination of gross alpha and beta activity in seafood using liquid scintillation counting and microwave digestion for fast sample decomposition. The general group of seafood was divided into two groups based on its structure, whether it has shell or not. The selected group of radionuclides was chosen with respect to military significance, radiotoxicity, and possibility of potential misuse. 90 Sr and 239 Pu were selected as model radionuclides. (author)

  16. Dosimetry of natural and man-made alpha emitters in plankton

    International Nuclear Information System (INIS)

    Paschoa, A.S.; Baptista, G.B.; Wrenn, M.E.; Eisenbrid, M.

    1980-11-01

    Comparison between the natural and man-made alpha radiation dose rates to plankton can be important for predicting the potential long-term effects on aquatic biota resulting from the routine or accidental radioactive releases from the nuclear fuel cycle. A contribution is made here towards the goal of comparing natural with man-made alpha radiation dose rates to plankton using the same method of calculation in both cases. (Author) [pt

  17. State of the art of D ampersand D Instrumentation Technology: Alpha counting in the presence of high background

    International Nuclear Information System (INIS)

    Dickerman, C.E.

    1995-08-01

    Discrimination of alpha activity in the presence of a high radiation background has been identified as an area of concern to be studied for D ampersand D applications. Upon evaluating the range of alpha detection needs for D ampersand D operations, we have expanded this study to address the operational concern of greatly expediting alpha counting of rough surfaces and rubble. Note that the term, ''rough surfaces'' includes a wide range of practical cases, including contaminated equipment and work surfaces. We have developed provisional applications requirements for instrumentation of this type; and we also have generated the scope of a program of instrument evaluation and testing, with emphasis on practical implementation. In order to obtain the full operational benefit of alpha discrimination in the presence of strong beta-gamma radiation background, the detection system must be capable of some form of remote or semi-remote operation in order to reduce operator exposure. We have identified a highly promising technique, the long-range alpha detector (LRAD), for alpha discrimination in the presence of high radiation background. This technique operates upon the principle of transporting alphaionized air to an ionization detector. A transport time within a few seconds is adequate. Neither the provisional requirements nor the evaluation and testing scope were expressly tailored to force the selection of a LRAD technology, and they could be used as a basis for studies of other promising technologies. However, a technology that remotely detects alpha-ionized air (e. g., LRAD) is a natural fit to the key requirements of rejection of high background at the survey location and operator protection. Also, LRAD appears to be valuable for D ampersand D applications as a means of greatly expediting surface alpha-activity surveys that otherwise would require performing time-consuming scans over surfaces of interest with alpha detector probes, and even more labor-intensive surface

  18. Photophysics of GaN single-photon emitters in the visible spectral range

    Science.gov (United States)

    Berhane, Amanuel M.; Jeong, Kwang-Yong; Bradac, Carlo; Walsh, Michael; Englund, Dirk; Toth, Milos; Aharonovich, Igor

    2018-04-01

    In this work, we present a detailed photophysical analysis of recently discovered, optically stable single-photon emitters (SPEs) in gallium nitride (GaN). Temperature-resolved photoluminescence measurements reveal that the emission lines at 4 K are three orders of magnitude broader than the transform-limited width expected from excited-state lifetime measurements. The broadening is ascribed to ultrafast spectral diffusion. The photophysical study on several emitters at room temperature (RT) reveals an average brightness of (427 ±215 )kCounts /s . Finally, polarization measurements from 14 emitters are used to determine visibility as well as dipole orientation of defect systems within the GaN crystal. Our results underpin some of the fundamental properties of SPEs in GaN both at cryogenic and RT, and define the benchmark for future work in GaN-based single-photon technologies.

  19. TENORM wastes and the potential alpha radiation dose to aquatic biota

    International Nuclear Information System (INIS)

    Paschoa, A.S.

    2002-01-01

    In the years seventies release-rates and derived limits for releasing radionuclides into the environment were adopted for each particular radionuclide and for a number of pathways. The release-rate limit adopted for alpha emitters was 10 15 Bq.y -1 for a single site, but limited to 10 14 Bq.y -1 for 226 Ra and supported 210 Po. In addition, to meet the requirements of the London Convention, a derived limit should be expressed in terms of concentration, which for alpha emitters was 10 10 Bq.t -1 , but limited to 10 14 Bq.t -1 for 226 Ra and supported 210 Po, assuming an upper limit to the mass dumping rate of 10 5 t per year at a single dumping site. New data on the radioactivity in the marine environment and biota, including plankton, indicated a potential alpha radiation dose to these aquatic organisms due to the release of technologically enhanced naturally occurring radioactive materials (TENORM) wastes. At the highest accumulation of 239 Pu in the zooplankton Gammarus in Thule, Greenland, due to an accidental release associated with military activities, the dose rate reached about 0.14 μGy.h -1 . Such dose rate was similar to that received by the phytoplankton Chaetoceros and Rhizosolenia from Agulhas current, Africa, due to naturally occurring radioactive materials (NORM) supposedly enhanced for almost one century of gold mining at first, and subsequently because of heap-leaching uranium extraction from the tailings left behind by earlier gold miners. The paper will discuss the alpha radiation dose to aquatic biota, in general, and to plankton, in particular, due to potential releases of TENORM wastes in the aquatic environment. (author)

  20. Review of measurement techniques for stack monitoring of long-lived alpha emitters

    International Nuclear Information System (INIS)

    Kordas, J.F.; Phelps, P.L.

    1978-01-01

    As a result of the promulgation of new guidelines by the Environmental Protection Agency (40 CFR 190) for releases of long-lived, alpha-emitting substances, the stack-monitoring requirements for measuring long-lived alpha particles may change in terms of both monitored isotopes and the detection levels. This paper briefly reviews stack-monitoring requirements for long-lived alpha-emitting particles. It also examines the currently deployed alpha-particulate, stack-monitoring systems and discusses prototype systems that may be applicable to stack monitoring

  1. Targeted alpha therapy: Applications and current status

    International Nuclear Information System (INIS)

    Bruchertseifer, Frank

    2017-01-01

    Full text: The field of targeted alpha therapy has been developed rapidly in the last decade. Besides 223 Ra, 211 At and 212 Pb/ 212 Bi the alpha emitters 225 Ac and 213 Bi are promising therapeutic radionuclides for application in targeted alpha therapy of cancer and infectious diseases. The presentation will give a short overview about the current clinical treatments with alpha emitting radionuclides and will place an emphasis on the most promising clinical testing of peptides and antibodies labelled with 225 Ac and 213 Bi for treatment of metastatic castration-resistant prostate cancer patients with glioma and glioblastoma multiform, PSMA-positive tumor phenotype and bladder carcinoma in situ. (author)

  2. Risk estimates for exposure to alpha emitters

    International Nuclear Information System (INIS)

    1982-07-01

    The primary scope of this report is to evaluate the risk of lung cancer from occupational exposure to short-lived daughters of radon and thoron. The Subcommittee on Risk Estimates considers that inhalation of radon and thoron daughters is the major radiation hazard from alpha radiation in uranium mining. The secondary scope of this report is the consideration of the applicability of the risk estimates derived from miners to the general public. The risk to members of the public from radium-226 in drinking water is also considered. Some research requirments are suggested

  3. Counting efficiency for liquid scintillator systems with a single multiplier phototube

    International Nuclear Information System (INIS)

    Grau Malonda, A.; Garcia-Torano, E.

    1984-01-01

    In this paper counting efficiency as a function of a free parameter (the figure of merit) has been computed. The results are applicable to liquid scintillator systems with a single multiplier phototube. Tables of counting efficiency for 62 pure beta emitters are given for figures of merit in the range 0.25 to 50. (Author) 16 refs

  4. Design and Development of Emittance Measurement Device by Using the Pepper-pot Technique

    Science.gov (United States)

    Pakluea, S.; Rimjaem, S.

    2017-09-01

    Transverse emittance of a charged particle beam is one of the most important properties that reveals the quality of the beam. It is related to charge density, transvers size and angular displacement of the beam in transverse phase space. There are several techniques to measure the transverse emittance value. One of practical methods is the pepper-pot technique, which can measure both horizontal and vertical emittance value in a single measurement. This research concentrates on development of a pepper-pot device to measure the transverse emittance of electron beam produced from an accelerator injector system, which consists of a thermionic cathode RF electron gun and an alpha magnet, at the Plasma and Beam Physics Research Facility, Chiang Mai University. Simulation of beam dynamics was conducted with programs PARMELA, ELEGANT and self-developed codes using C and MATLAB. The geometry, dimensions and location of the pepper-pot as well as its corresponding screen station position were included in the simulation. The result from this study will be used to design and develop a practical pepper-pot experimental station.

  5. Microprecipitation of barium sulfate as a suitable source for measurements of 226Ra by alpha spectrometry

    International Nuclear Information System (INIS)

    Fernandez-Cata, Geyser; Isaac-Olive, Keila : E-mail. geyser@instec.cu

    2007-01-01

    One of the most hazardous radionuclides released into the environment is the uranium's daughter 226 Ra. This nuclide behaves similar to calcium, therefore is highly toxic for humans. One of the suitable methods for its determination is alpha spectrometry. This technique, however, has as main drawback the source preparation which should be infinitely thin and massless, of regular, known, and reproducible shape, smaller in area than the active area of the detector and new (no sputtering or recoil losses). Among the various ways of preparing an alpha source are the electrodeposition and microprecipitation. Radium electrodeposition is not suitable to carry out because of the high reduction potential of this element, therefore non aqueous media is required and the chemical yield is not good. Radium however can be precipitated with barium sulfate and our previous work has shown that the precipitation is selective to this element in the presence of other alpha emitters such as uranium and polonium but divalent cations are incorporated to it. At the same time, manganese dioxide also precipitates radium free of divalent cations but alpha emitters such as uranium are present as well. The objective of this work was to establish a chemical procedure for the determination of 226 Ra in natural water by alpha spectrometry. The general methodology includes a preconcentration using a non selective coprecipitation via manganese dioxide (where cations are not included but alpha emitters do). Once the manganese dioxide is filtrated, it is re-dissolved and a selective microprecipitation using barium sulphate is carried out (where the only alpha emitter is radium). Details of the procedure, separation methods, source quality and discussion of the results will be given in the paper. (Author)

  6. Impact of water temperature and structural parameters on the hydraulic labyrinth-channel emitter performance

    Directory of Open Access Journals (Sweden)

    Ahmed I. Al-Amoud

    2014-06-01

    Full Text Available The effects of water temperature and structural parameters of a labyrinth emitter on drip irrigation hydraulic performance were investigated. The inside structural parameters of the trapezoidal labyrinth emitter include path width (W and length (L, trapezoidal unit numbers (N, height (H, and spacing (S. Laboratory experiments were conducted using five different types of labyrinth-channel emitters (three non-pressure compensating and two pressure-compensating emitters commonly used for subsurface drip irrigation systems. The water temperature effect on the hydraulic characteristics at various operating pressures was recorded and a comparison was made to identify the most effective structural parameter on emitter performance. The pressure compensating emitter flow exponent (x average was 0.014, while non-pressure compensating emitter’s values average was 0.456, indicating that the sensitivity of non-pressure compensating emitters to pressure variation is an obvious characteristic (p<0.001 of this type of emitters. The effects of water temperature on emitter flow rate were insignificant (p>0.05 at various operating pressures, where the flow rate index values for emitters were around one. The effects of water temperature on manufacturer’s coefficient of variation (CV values for all emitters were insignificant (p>0.05. The CV values of the non-pressure compensating emitters were lower than those of pressure compensating emitters. This is typical for most compensating models because they are manufactured with more elements than non-compensating emitters are. The results of regression analysis indicate that N and H are the essential factors (p<0.001 to affect the hydraulic performance.

  7. High specific activity N-Acetyl-3{sup H}-{alpha}-Aspartyl- L-Glutamic at micro mole scale; Sintesis de N-Acetil-3{sup H}- {alpha} -Aspartil-Glutamico a escala de Micromoles

    Energy Technology Data Exchange (ETDEWEB)

    Suarez, C

    1984-07-01

    High specific activity N-Acetyl-3{sup H}- {alpha} -Aspartyl-I-Glutamic acid at micro mole scale in prepared acetylating L- {alpha} -Aspartyl-L-glutamic with 3{sup H}-acetic anhydride in re distilled toluene. The product le purified through cationic and anionic columns. The radiochemical purity as determined by thin-layer chromatography is greater then 99% at the time preparation. (Author) 5 refs.

  8. Determination of phosphorus in biological samples by thermal neutron activation followed by β--counting

    International Nuclear Information System (INIS)

    Weginwar, R.G.; Samudralwar, D.L.; Garg, A.N.

    1989-01-01

    Phosphorus was determined using the β - emitter 32 P by instrumental neutron activation analysis (INAA) in several NBS and IAEA standards, and in samples of biological origin such as human and animal blood, cancerous tissue, edible plant leaves, diets, milk samples, etc. The method involves thermal neutron irradiation (for 2-10 h in a reactor) followed by β - counting on an end-window gas flow proportional counter using aluminium filter. The results are within ±10% of the certified values in most cases. (author) 29 refs.; 3 tabs

  9. Nicotinic cholinergic receptor in brain detected by binding of. cap alpha. -(/sup 3/H)bungarotoxin

    Energy Technology Data Exchange (ETDEWEB)

    Eterovic, V A; Bennett, E L

    1974-01-01

    ..cap alpha..-(/sup 3/H)bungarotoxin was prepared by catalytic reduction of iodinated ..cap alpha..-bungarotoxin with tritium gas. Crude mitochondrial fraction from rat cerebral cortex bound 40 x 10/sup -15/ to 60 x 10/sup -15/ moles of ..cap alpha..-(/sup 3/H)bungarotoxin per mg of protein. This binding was reduced by 50% in the presence of approx. 10/sup -6/ M d-tubocurarine or nicotine, 10/sup -5/ M acetylcholine, 10/sup -4/ M carbamylcholine or decamethonium or 10/sup -3/ M atropine. Hexamethonium and eserine were the least effective of the drugs tested. Crude mitochondrial fraction was separated into myelin, nerve endings, and mitochondria. The highest binding of toxin per mg of protein was found in nerve endings, as well as the greatest inhibition of toxin binding by d-tubocurarine. Binding of ..cap alpha..-(/sup 3/H)bungarotoxin to membranes obtained by osmotic shock of the crude mitochondrial fraction indicates that the receptor for the toxin is membrane bound. /sup 125/I-labeled ..cap alpha..-bungarotoxin, prepared with Na/sup 125/I and chloramine T, was highly specific for the acetylcholine receptor in diaphragm, however, it was less specific and less reliable than ..cap alpha..-(/sup 3/H)bungarotoxin in brain. It is concluded that a nicotinic cholinergic receptor exists in brain, and that ..cap alpha..-(/sup 3/H)bungarotoxin is a suitable probe for this receptor.

  10. Procedure for determination of alpha emitters in urine and dregs samples

    International Nuclear Information System (INIS)

    Serdeiro, Nelida H.

    2005-01-01

    The purpose of this work is to establish the procedure for the identification and quantification of emitting alpha radionuclides in urine and dregs samples. This procedure are applied to all laboratories of the countries of the Project ARCAL LXXVII that determinate alpha emitting radionuclides in biological samples for biological assessment [es

  11. A study of solar flare energy transport based on coordinated H-alpha and X-ray observations

    International Nuclear Information System (INIS)

    Canfield, R.C.; Wulser, J.; Zarro, D.M.; Dennis, B.R.

    1991-01-01

    The temporal evolution of the ratio between H-alpha to nonthermal hard X-ray emission was investigated using coordinated H-alpha and hard- and soft-X-ray observations of five solar flares (on May 7, June 23, June 24, and June 25, 1980 and on April 30, 1985). These observations were used to estimate the emitted flare energy flux F(H-alpha) in H-alpha, the flux of F(2O) energy deposited by nonthermal electrons with energies above 20 keV, and the pressure p(c) of soft X-ray-emitting plasma as functions of time during the impulsive phase of each flare. It was found that the F(H-alpha)/F(2O) ratio shows a power-law dependence on F(2O), with a slope that differs slightly from that predicted by the static thick-target model of solar transport. Results also indicate that the power-law dependence is modified by hydrostatic pressure effects. 25 refs

  12. Targeted alpha therapy: Applications and current status

    Energy Technology Data Exchange (ETDEWEB)

    Bruchertseifer, Frank, E-mail: frank.bruchertseifer@ec.europa.eu [European Commission, Joint Research Centre, Karlsruhe (Germany)

    2017-07-01

    Full text: The field of targeted alpha therapy has been developed rapidly in the last decade. Besides {sup 223}Ra, {sup 211}At and {sup 212}Pb/{sup 212}Bi the alpha emitters {sup 225}Ac and {sup 213}Bi are promising therapeutic radionuclides for application in targeted alpha therapy of cancer and infectious diseases. The presentation will give a short overview about the current clinical treatments with alpha emitting radionuclides and will place an emphasis on the most promising clinical testing of peptides and antibodies labelled with {sup 225}Ac and {sup 213}Bi for treatment of metastatic castration-resistant prostate cancer patients with glioma and glioblastoma multiform, PSMA-positive tumor phenotype and bladder carcinoma in situ. (author)

  13. Uranium analysis in Cypriot groundwaters by total alpha-radiometry and alpha-spectroscopy

    International Nuclear Information System (INIS)

    Efstathiou, Maria; Kiliari, Tasoula; Pashalidis, Ioannis

    2011-01-01

    Two different alpha-radiometric methods (e.g. alpha-spectroscopy and alpha-particle counting) have been applied to the determination of uranium in Cypriot groundwater samples after separation of the radionuclides by cation exchange using Chelex-100 and its electrodeposition on stainless steel planchettes. The data obtained were compared to show the advantages and disadvantages of the two radiometric methods, determine the alpha-radioactivity concentration and the radiation dose associated with the use of the studied groundwaters. Calibration of the methods was performed by means of uranium standard solutions and the corresponding data were used to evaluate linear range, detector efficiency, detection limits, value of the information obtained, and time of analysis of the methods. Comparison of the data obtained from calibration and natural sample measurements has shown that alpha-particle counting with a simple alpha-radiometer (equipped with a semiconductor detector) may offer only an activity value and not detailed information about the isotopic composition but it is the fastest method and the method of choice if only a screening method for the alpha-radioactivity measurement is required. Based on the alpha-radioactivity data, the corresponding radiation dose was estimated for situations where the groundwaters are used for drinking water purposes.

  14. Problems associated with scintillation counting of NaH14CO3 and gel suspension counting of Ba14CO3

    International Nuclear Information System (INIS)

    MacRae, J.C.; Wilson, S.

    1978-01-01

    Liquid NaH 14 CO 3 was assayed in emulsion-type (NE260 and Unisolve) and dioxan-based (NE250) scintillation cocktails contained in glass or polyethylene vials kept at 2 0 or 24-30 0 C. Different particle size ranges of standard Ba 14 CO 3 were assayed by gel suspension counting in Cabosil scintillation cocktail and in NE260 following solubilisation in EDTA-tetrasodium salt. Initial detectable activities of NaH 14 CO 3 in glass and polyethylene vials in NE250, NE260 and Unisolve were 97 and 96, 68 and 83, 71 and 89% of the true value respectively. Subsequent losses of activity over 7 days with the emulsion-type scintillators was greater from the polyethylene vials. Addition of phenylethylamine to the NE260 and Unisolve cocktails gave the true activity levels for all vials with no loss of activity over 6 days. When different particle size ranges of Standard Ba 14 CO 3 were suspended in Cabosil scintillation cocktail there was considerable variation in counting efficiency (77-88%) with little relationship between particle size and counting efficiency. The relationship between counting efficiency and channels ratio was not sufficiently precise for predictive purposes. Solubilisation of Ba 14 CO 3 in EDTA-tetrasodium salt gave similar counting efficiency and channels ratio values for all samples. (U.K.)

  15. Low-emittance Storage Rings

    CERN Document Server

    Wolski, Andrzej

    2014-01-01

    The effects of synchrotron radiation on particle motion in storage rings are discussed. In the absence of radiation, particle motion is symplectic, and the beam emittances are conserved. The inclusion of radiation effects in a classical approximation leads to emittance damping: expressions for the damping times are derived. Then, it is shown that quantum radiation effects lead to excitation of the beam emittances. General expressions for the equilibrium longitudinal and horizontal (natural) emittances are derived. The impact of lattice design on the natural emittance is discussed, with particular attention to the special cases of FODO-, achromat- and theoretical-minimum-emittance-style lattices. Finally, the effects of betatron coupling and vertical dispersion (generated by magnet alignment and lattice tuning errors) on the vertical emittance are considered.

  16. Effective liquid drop description for alpha decay of atomic nuclei

    International Nuclear Information System (INIS)

    Tavares, O.A.P.; Duarte, S.B.; Rodriguez, O.; Guzman, F.; Goncalves, M.; Garcia, F.

    1998-06-01

    Alpha decay half-lives are presented in the framework of an effective liquid drop model for different combination of mass transfer descriptions and inertia coefficients. Calculated half-life-values for ground-state to ground-state favoured alpha transitions are compared with available, updated experimental data. Results have shown that the present model is very suitable to treat the alpha decay process on equal foot as cluster radioactivity and cold fission processes. Better agreement with the data is found when the sub-set of even-even alpha emitters are considered in the calculation. (author)

  17. All-optical control and super-resolution imaging of quantum emitters in layered materials.

    Science.gov (United States)

    Kianinia, Mehran; Bradac, Carlo; Sontheimer, Bernd; Wang, Fan; Tran, Toan Trong; Nguyen, Minh; Kim, Sejeong; Xu, Zai-Quan; Jin, Dayong; Schell, Andreas W; Lobo, Charlene J; Aharonovich, Igor; Toth, Milos

    2018-02-28

    Layered van der Waals materials are emerging as compelling two-dimensional platforms for nanophotonics, polaritonics, valleytronics and spintronics, and have the potential to transform applications in sensing, imaging and quantum information processing. Among these, hexagonal boron nitride (hBN) is known to host ultra-bright, room-temperature quantum emitters, whose nature is yet to be fully understood. Here we present a set of measurements that give unique insight into the photophysical properties and level structure of hBN quantum emitters. Specifically, we report the existence of a class of hBN quantum emitters with a fast-decaying intermediate and a long-lived metastable state accessible from the first excited electronic state. Furthermore, by means of a two-laser repumping scheme, we show an enhanced photoluminescence and emission intensity, which can be utilized to realize a new modality of far-field super-resolution imaging. Our findings expand current understanding of quantum emitters in hBN and show new potential ways of harnessing their nonlinear optical properties in sub-diffraction nanoscopy.

  18. Self-absorption and self-scattering in emitter source of alpha particles

    International Nuclear Information System (INIS)

    Terini, R.A.

    1990-01-01

    This paper describes preliminary results on spectrometric analysis and activity measurements of alpha-emitting sources prepared by evaporation on mylar. The measurements were made with a Si surface barrier detector. By the analysis of the angular distribuition of the alpha particles emitted, it was possible to observe that the width of the spectrum low energy tail increases with the emission angle θ, due to the energy degradation in the source material, which affects the measured particles energy. The source activity was also measured from detection solid angles of approx. 10 -1 and aprox. 10 -3 Sr, as a function of θ. The absolute activity of the alpha source was determined and a discussion is present on the ideal conditions necessary for such measurements. (author) [pt

  19. Rare Earth Garnet Selective Emitter

    Science.gov (United States)

    Lowe, Roland A.; Chubb, Donald L.; Farmer, Serene C.; Good, Brian S.

    1994-01-01

    Thin film Ho-YAG and Er-YAG emitters with a platinum substrate exhibit high spectral emittance in the emission band (epsilon(sub lambda) approx. = 0.75, sup 4)|(sub 15/2) - (sup 4)|(sub 13/2),for Er-YAG and epsilon(sub lambda) approx. = 0.65, (sup 5)|(sub 7) - (sup 5)|(sub 8) for Ho-YAG) at 1500 K. In addition, low out-of-band spectral emittance, epsilon(sub lambda) less than 0.2, suggest these materials would be excellent candidates for high efficiency selective emitters in thermophotovoltaic (TPV) systems operating at moderate temperatures (1200-1500 K). Spectral emittance measurements of the thin films were made (1.2 less than lambda less than 3.0 microns) and compared to the theoretical emittances calculated using measured values of the spectral extinction coefficient. In this paper we present the results for a new class of rare earth ion selective emitters. These emitters are thin sections (less than 1 mm) of yttrium aluminum garnet (YAG) single crystal with a rare earth substitutional impurity. Selective emitters in the near IR are of special interest for thermophotovoltaic (TPV) energy conversion. The most promising solid selective emitters for use in a TPV system are rare earth oxides. Early spectral emittance work on rare earth oxides showed strong emission bands in the infrared (0.9 - 3 microns). However, the emittance outside the emission band was also significant and the efficiency of these emitters was low. Recent improvements in efficiency have been made with emitters fabricated from fine (5 - 10 microns) rare earth oxide fibers similar to the Welsbach mantle used in gas lanterns. However, the rare earth garnet emitters are more rugged than the mantle type emitters. A thin film selective emitter on a low emissivity substrate such as gold, platinum etc., is rugged and easily adapted to a wide variety of thermal sources. The garnet structure and its many subgroups have been successfully used as hosts for rare earth ions, introduced as substitutional

  20. IPHAS: Surveying the North Galactic Plane in H-alpha

    NARCIS (Netherlands)

    Drew, J.E.; Groot, P.J.; Morales-Rueda, L.; Roelofs, G.H.A.

    2005-01-01

    H-alpha emission is ubiquitous in our Galaxy. It traces ionised gas of assorted nebulae such as HII regions, planetary nebulae, Wolf-Rayet nebulae, and supernova remnants. It is a strong signature of active stars, interacting binaries, very massive stars (especially supergiants, Luminous Blue

  1. The human intestinal fatty acid binding protein (hFABP2) gene is regulated by HNF-4{alpha}

    Energy Technology Data Exchange (ETDEWEB)

    Klapper, Maja [Molecular Nutrition, Institute of Human Nutrition and Food Science, Christian-Albrechts-University of Kiel, Heinrich-Hecht-Platz 10, D-24118 Kiel (Germany); Boehme, Mike [Molecular Nutrition, Institute of Human Nutrition and Food Science, Christian-Albrechts-University of Kiel, Heinrich-Hecht-Platz 10, D-24118 Kiel (Germany); Nitz, Inke [Molecular Nutrition, Institute of Human Nutrition and Food Science, Christian-Albrechts-University of Kiel, Heinrich-Hecht-Platz 10, D-24118 Kiel (Germany); Doering, Frank [Molecular Nutrition, Institute of Human Nutrition and Food Science, Christian-Albrechts-University of Kiel, Heinrich-Hecht-Platz 10, D-24118 Kiel (Germany)

    2007-04-27

    The cytosolic human intestinal fatty acid binding protein (hFABP2) is proposed to be involved in intestinal absorption of long-chain fatty acids. The aim of this study was to investigate the regulation of hFABP2 by the endodermal hepatocyte nuclear factor 4{alpha} (HNF-4{alpha}), involved in regulation of genes of fatty acid metabolism and differentiation. Electromobility shift assays demonstrated that HNF-4{alpha} binds at position -324 to -336 within the hFABP2 promoter. Mutation of this HNF-4 binding site abolished the luciferase reporter activity of hFABP2 in postconfluent Caco-2 cells. In HeLa cells, this mutation reduced the activation of the hFABP2 promoter by HNF-4{alpha} by about 50%. Thus, binding element at position -336/-324 essentially determines the transcriptional activity of promoter and may be important in control of hFABP2 expression by dietary lipids and differentiation. Studying genotype interactions of hFABP2 and HNF-4{alpha}, that are both candidate genes for diabetes type 2, may be a powerful approach.

  2. Cooling mechanical motion via vacuum effect of an ensemble of quantum emitters.

    Science.gov (United States)

    Nie, Wenjie; Chen, Aixi; Lan, Yueheng

    2015-11-30

    We design a hybrid optomechanical setup, in which an ensemble of quantum emitters is coupled with a movable mirror through vacuum interaction. The optical cavity is driven along with the quantum emitters and therefore the coupling between the cavity field and the ensemble determines the dynamics of the coupled system. In particular, we investigated the influence of the vacuum coupling strength on the effective frequency and the effective damping rate of the movable mirror, which shows that the vacuum interaction enhances greatly the effective damping rate. Further, the cooling characteristics of the mechanical resonator is analyzed in detail by counting the effective phonon number in the mirror's motion. It is found that the ground-state cooling of the mechanical motion can be approached in the bad cavity limit when the vacuum coupling is included. The dependence of the cooling of the mechanical motion on the parameters of the cavity and the quantum emitter is investigated in detail numerically.

  3. Radiological hazards of alpha-contaminated waste

    International Nuclear Information System (INIS)

    Rodgers, J.C.

    1982-01-01

    The radiological hazards of alpha-contaminated wastes are discussed in this overview in terms of two components of hazard: radiobiological hazard, and radioecological hazard. Radiobiological hazard refers to human uptake of alpha-emitters by inhalation and ingestion, and the resultant dose to critical organs of the body. Radioecological hazard refers to the processes of release from buried wastes, transport in the environment, and translocation to man through the food chain. Besides detailing the sources and magnitude of hazards, this brief review identifies the uncertainties in their estimation, and implications for the regulatory process

  4. Operating program for an automatic alpha-beta counting system-FAG

    Energy Technology Data Exchange (ETDEWEB)

    German, U; Levinson, L; Shemesh, Y; Peled, O; Weistein, M [Israel Atomic Energy Commission, Beersheba (Israel). Nuclear Research Center-Negev

    1996-12-01

    An alpha and beta counting system - FAG, for planchette samples is operated at the Health Physics department`s laboratory of the NRCN. The system consists of a proportional detector of 8`` diameter operated in coincidence with a guard detector, an automatic sample changer (FAG-FHT770E) and electronics (FAG- FHT1100 digital counter and controller). The original operation mode of the system was based on manual tasks handled by the FHT1100 electronics. Pin option for a basic computer keyboard operation was available too. A computer with appropriate 110 card was connected to the system and a new operating program was developed which enables full automatic control of the various components. The program includes activity calculations and statistical checks as well as data management. The program which was developed enables computer control of all components of the system, based on bi-directional communication. The computer software controls the FHT1100 electronics using the R5232 protocol and the sample changer by an additional 110 card Contec Inodel PIO-48W(PC). The computer controls the whole operation of the system: change of samples, high voltage change, start, stop etc. It handles in the appropriate order the different commands and operates the electronic and mechanic components accordingly (authors).

  5. Operating program for an automatic alpha-beta counting system-FAG

    International Nuclear Information System (INIS)

    German, U.; Levinson, L.; Shemesh, Y.; Peled, O.; Weistein, M.

    1996-01-01

    An alpha and beta counting system - FAG, for planchette samples is operated at the Health Physics department's laboratory of the NRCN. The system consists of a proportional detector of 8'' diameter operated in coincidence with a guard detector, an automatic sample changer (FAG-FHT770E) and electronics (FAG- FHT1100 digital counter and controller). The original operation mode of the system was based on manual tasks handled by the FHT1100 electronics. Pin option for a basic computer keyboard operation was available too. A computer with appropriate 110 card was connected to the system and a new operating program was developed which enables full automatic control of the various components. The program includes activity calculations and statistical checks as well as data management. The program which was developed enables computer control of all components of the system, based on bi-directional communication. The computer software controls the FHT1100 electronics using the R5232 protocol and the sample changer by an additional 110 card Contec Inodel PIO-48W(PC). The computer controls the whole operation of the system: change of samples, high voltage change, start, stop etc. It handles in the appropriate order the different commands and operates the electronic and mechanic components accordingly (authors)

  6. Use of (3H) and (125I) tracers in steroid radioimmunoassays

    International Nuclear Information System (INIS)

    Jeffcoate, S.L.

    1975-01-01

    The comparative use of 3 H and 125 I tracers in steroid radioimmunoassays will be discussed around the following points: - 3 H. Advantages: they can be purchased commercially and have a long shelf-life. Disadvantages: they may have reduced affinity for antibodies due to ''isotope effects''; the counting of β-emitters is more expensive and difficult; 3 H tracers are not available for all steroids. - 125 I. Advantages: gamma-counting is cheaper, simpler and more precise; 125 I tracers may have higher affinity for antibodies than unlabelled steroids; 125 I can be used to label any steroid. Disadvantages: 125 I tracers have a limited shelf-life (n.b. six months for 125 I histamine tracers). The high affinity of some tracers will be a big disadvantage if the unlabelled steroid cannot compete effectively

  7. Low-priced, time-saving, reliable and stable LR-115 counting system

    International Nuclear Information System (INIS)

    Tchorz-Trzeciakiewicz, D.E.

    2015-01-01

    Nuclear alpha particles leave etches (tracks) when they hit the surface of a LR-115 detector. The density of these tracks is used to measure radon concentration. Counting these tracks by human sense is tedious and time-consuming procedure and may introduce counting error, whereas most available automatic and semiautomatic counting systems are expensive or complex. An uncomplicated, robust, reliable and stable counting system using freely available on the Internet software as Digimizer™ and PhotoScape was developed and proposed. The effectiveness of the proposed procedure was evaluated by comparing the amount of tracks counted by software with the amount of tracks counted manually for 223 detectors. The percentage error for each analysed detector was obtained as a difference between automatic and manual counts divided by manual count. For more than 97% of detectors, the percentage errors oscillated between −3% and 3%. - Highlights: • Semiautomatic, uncomplicated procedure was proposed to count the amount of alpha tracks. • Freely available software on the Internet used as alpha tracks counting system for LR-115. • LR-115 detectors used to measure radon concentration and radon exhalation rate

  8. The relationship between I{sub H{sub {alpha}}} /(I{sub SiH}{sup *}){sup 2} and crystalline volume fraction in microcrystalline silicon growth

    Energy Technology Data Exchange (ETDEWEB)

    Chantana, Jakapan; Higuchi, Takuya; Nagai, Tomoyuki; Sasaki, Shota; Sobajima, Yasushi; Toyama, Toshihiko; Sada, Chitose; Matsuda, Akihisa; Okamoto, Hiroaki [Graduate School of Engineering Science, Osaka University, 1-3 Machikaneyama-cho, Toyonaka, Osaka 560-8531 (Japan)

    2010-03-15

    Optical-emission-intensity ratio of I{sub H{sub {alpha}}} /(I{sub SiH}{sup *}) during film growth has been used as a simple indicator to predict crystallinity (crystal-volume fraction: X{sub C}) in the resulting microcrystalline silicon ({mu}c-Si:H) thin films. The relationship between I{sub H{sub {alpha}}} /(I{sub SiH}{sup *}) and X{sub C} has been checked under a wide variety of film-preparation conditions including low-deposition-rate (<0.1 nm/s) and high-deposition-rate (>5 nm/s) cases. On the basis of theoretical consideration, we have proposed optical-emission-intensity ratio of I{sub H{sub {alpha}}} /(I{sub SiH}{sup *}) {sup 2} as a new indicator of X{sub C} during film growth of {mu}c-Si:H. (Abstract Copyright [2010], Wiley Periodicals, Inc.)

  9. Active packaged lamb with oxygen scavenger/carbon dioxide emitter sachet: physical-chemical and microbiological stability during refrigerated storage

    Directory of Open Access Journals (Sweden)

    Marco Antonio Trindade

    2013-09-01

    Full Text Available Lamb meat has been commercialized in Brazil almost exclusively as a frozen product due to the longer shelf life provided by freezing when compared to refrigeration. However, as a result of the current trend of increased demand for convenience products, a need has emerged for further studies to facilitate the marketing of refrigerated lamb cuts. The aim of the present study was to evaluate the contribution of active packaging technology in extending the shelf life of lamb loins (Longissimus lumborum stored under refrigeration (1±1 ° C when compared to the traditional vacuum packaging. For this purpose, two kinds of sachets were employed: oxygen scavenger sachet and oxygen scavenger/carbon dioxide emitter sachet. Experiments were conducted in three treatments: 1 Vacuum (Control, 2 Vacuum + oxygen scavenger sachet and 3 Vacuum + oxygen scavenger/carbon dioxide emitter sachet. Microbiological (counts of anaerobic psychrotrophs, coliform at 45 ° C, coagulase-positive staphylococci, Salmonella and lactic acid bacteria and physical-chemical (thiobarbituric acid reactive substances, objective color, pH value, water loss from cooking and shear force analyses were carried out weekly for a total storage period of 28 days. The experiment was performed three times for all treatments. Results showed that the lamb meat remained stable with respect to the majority of the evaluated physical and chemical indexes and remained within the standards established by Brazilian legislation for pathogenic microorganisms throughout the storage period in all three packaging systems. However, all treatments presented elevated counts of anaerobic psychrotrophic microorganisms and lactic acid bacteria, reaching values above 10(7 CFU/g at 28 days of storage. Thus, under the conditions tested, neither the oxygen scavenger sachet nor the dual function sachet (oxygen scavenger/carbon dioxide emitter were able to extend the shelf life of refrigerated lamb loin when added to this

  10. Effect of the CO2/SiH4 Ratio in the p-μc-SiO:H Emitter Layer on the Performance of Crystalline Silicon Heterojunction Solar Cells

    OpenAIRE

    Sritharathikhun, Jaran; Krajangsang, Taweewat; Moollakorn, Apichan; Inthisang, Sorapong; Limmanee, Amornrat; Hongsingtong, Aswin; Boriraksantikul, Nattaphong; Taratiwat, Tianchai; Akarapanjavit, Nirod; Sriprapha, Kobsak

    2014-01-01

    This paper reports the preparation of wide gap p-type hydrogenated microcrystalline silicon oxide (p-μc-SiO:H) films using a 40 MHz very high frequency plasma enhanced chemical vapor deposition technique. The reported work focused on the effects of the CO2/SiH4 ratio on the properties of p-μc-SiO:H films and the effectiveness of the films as an emitter layer of crystalline silicon heterojunction (c-Si-HJ) solar cells. A p-μc-SiO:H film with a wide optical band gap (E04), 2.1 eV, can be obtain...

  11. Mutual interference of alpha and beta signals in counting

    International Nuclear Information System (INIS)

    Zhang Fengxiang; Ren Wei; Tang Shaohua; Han Suping; Du Xiangyang.

    1993-01-01

    When multi-wire proportional counters are used for monitoring of mixed contamination of α and β radioactivity, both of the signals should be distinguished as far as possible from requirement of radiation protection. The rules provided by the recommendation standard of International Electrotechnical Committee (IEC) and the national standard of China indicate: For fixed personal surface contamination monitoring assembly, the response of the α-counting channel to β events should be smaller than 1% of response of the α-counting channel to α events, and the response of β-counting channel to β events should be smaller than that of the response of α-counting channel to the same events. To distinguish one kind of signal from another, amplitude discrimination method is used usually. (3 figs)

  12. Half-life of samarium-147

    CERN Document Server

    Kinoshita, N; Nakanishi, T

    2003-01-01

    The alpha-decay half-life of sup 1 sup 4 sup 7 Sm has been reevaluated. Known amounts of natural Sm and an alpha-emitter standard ( sup 2 sup 1 sup 0 Po, sup 2 sup 3 sup 8 U, or sup 2 sup 4 sup 1 Am) were mixed well to prepare thin sources for the simultaneous counting of sup 1 sup 4 sup 7 Sm and the alpha-emitter standard by means of an alpha-spectrometer using a silicon surface barrier detector. The alpha-disintegration rate of known amounts of sup 1 sup 4 sup 7 Sm was determined by reference to the alpha activity of the standard. The source preparation and counting were repeated to establish the reproducibility of the present half-life determination, and supplementary alpha spectrometry was carried out by a liquid-scintillation spectrometer. The arithmetic mean of the experimental half-life values was obtained to be (1.17 +- 0.02) x 10 sup 1 sup 1 y. This value is about 10% longer than the currently adopted value, (1.06 +- 0.02) x 10 sup 1 sup 1 y, and the possible factors for this difference are discussed...

  13. Determination of plutonium in urine samples from 24 h by ICP-W.f.'s and AMS

    International Nuclear Information System (INIS)

    Aragon del Valle, A.; Anton Mateos, M. P.; Chamizo Calvo, E.; Barrado Olmedo, A. I.; Yllera de Llano, A.

    2013-01-01

    The identification and quantification of alpha emitters in biological samples is essential to estimate the internal dose received by workers exposed. The object of this research is to assess the suitability of AMS and ICP-WSFS as measure alternative techniques to the EA of high resolution in the quantification of plutonium in urine 24h. (Author)

  14. Effect of alpha irradiation on UO{sub 2} surface reactivity in aqueous media

    Energy Technology Data Exchange (ETDEWEB)

    Jegou, C.; Muzeau, B.; Broudic, V.; Poulesquen, A.; Roudil, D. [Commissariat a l' Energie Atomique (CEA), Rhone Valley Research Center, DIEC/SESC/LMPA, Bagnols-sur-Ceze (France); Jorion, F. [Commissariat a l' Energie Atomique (CEA), Rhone Valley Research Center, DRCP/SE2A/LEMA, Bagnols-sur-Ceze (France); Corbel, C. [Commissariat a l' Energie Atomique (CEA), Saclay Research Center, DSM/DRECAM/SCM, Gif sur Yvette (France)

    2005-07-01

    The option of direct disposal of spent nuclear fuel in a deep geological formation raises the need to investigate the long-term behavior of the UO{sub 2} matrix in aqueous media subjected to {alpha}-{beta}-{gamma} radiation. The {beta}-{gamma} emitters account for most of the activity of spent fuel at the moment it is removed from the reactor, but diminish within a millennial time frame by over three orders of magnitude to less than the long-term activity. The latter persists over much longer time periods and must therefore be taken into account over a geological disposal time scale. Leaching experiments with solution renewal were carried out on UO{sub 2} pellets doped with alpha emitters ({sup 238}Pu and {sup 239}Pu) to quantify the impact of alpha irradiation on UO{sub 2} matrix alteration. Three batches of doped UO{sub 2} pellets with different alpha flux levels (3.30 x 10{sup 4}, 3.30 x 10{sup 5}, and 3.2 x 10{sup 6} {alpha} cm{sup -2} s{sup -1}) were studied. The results obtained in aerated and deaerated media immediately after sample annealing or interim storage in air provide a better understanding of the UO{sub 2} matrix alteration mechanisms under alpha irradiation. Interim storage in air of UO{sub 2} pellets doped with alpha emitters results in variations of the UO{sub 2} surface reactivity, which depends on the alpha particle flux at the interface and on the interim storage duration. The variation in the surface reactivity and the greater uranium release following interim storage cannot be attributed to the effect of alpha radiolysis in aerated media since the uranium release tends toward the same value after several leaching cycles for the doped UO{sub 2} pellet batches and spent fuel. Oxygen diffusion enhanced by alpha irradiation of the extreme surface layer and/or radiolysis of the air could account for the oxidation of the surface UO{sub 2} to UO{sub 2+x}. However, leaching experiments performed in deaerated media after annealing the samples and

  15. Incineration of technological waste contaminated with alpha emitters

    International Nuclear Information System (INIS)

    Otter, C.; Moncouyoux, J.P.; Cartier, R.; Durec, J.P.; Afettouche, R.

    1990-01-01

    A large R and D programme is in progress at the CEA on alpha-bearing waste incineration. The program is developed in the laboratory and a pilot plant including the following aspects: physico-chemical characterization of wastes, study of thermal decomposition of wastes, laboratory study of generated gases (first with inactive then with active wastes), development of an industrial pilot plant with inactive wastes, study of corrosion resistance of material (laboratory and pilot plant), study and qualification of nuclear measurements on wastes, ashes and equipment [fr

  16. Structure of the radio emission from the NGC 1579/LkH. cap alpha. 101 region

    Energy Technology Data Exchange (ETDEWEB)

    Brown, R L [National Radio Astronomy Observatory, Charlottesville, Va. (USA); Broderick, J J; Knapp, G R

    1976-06-01

    Radio-frequency observations at 3.7 and 11 cm of the NGC 1579/LkH..cap alpha..101 region show that the radio emission arises in a compact, < 1'' core concentric with a more extended approximately 1' emission region. At these wavelengths the compact component is optically thick, with a spectrum increasing as ..nu.., whereas the extended region is optically thin and contributes at least 80 per cent of the total flux density. LkH..cap alpha..101 appears to be the source of excitation for all of the radio emission; this result, together with the total infrared luminosity, suggests that an appropriate spectral classification for LkH..cap alpha..101 is B1 IIe.

  17. Protein backbone motions viewed by intraresidue and sequential H{sup N}-H{sup {alpha}} residual dipolar couplings

    Energy Technology Data Exchange (ETDEWEB)

    Voegeli, Beat; Yao Lishan; Bax, Ad [National Institutes of Health, Laboratory of Chemical Physics, National Institute of Diabetes and Digestive and Kidney Diseases (United States)], E-mail: bax@nih.gov

    2008-05-15

    Triple resonance E.COSY-based techniques were used to measure intra-residue and sequential H{sup N}-H{sup {alpha}} residual dipolar couplings (RDCs) for the third IgG-binding domain of protein G (GB3), aligned in Pf1 medium. Measurements closely correlate with values predicted on the basis of an NMR structure, previously determined on the basis of a large number of one-bond backbone RDCs measured in five alignment media. However, in particular the sequential H{sup N}-H{sup {alpha}} RDCs are smaller than predicted for a static structure, suggesting a degree of motion for these internuclear vectors that exceeds that of the backbone amide N-H vectors. Of all experimentally determined GB3 structures available, the best correlation between experimental {sup 1}H-{sup 1}H couplings is observed for a GB3 ensemble, previously derived to generate a realistic picture of the conformational space sampled by GB3 (Clore and Schwieters, J Mol Biol 355:879-886, 2006). However, for both NMR and X-ray-derived structures the {sup 1}H-{sup 1}H couplings are found to be systematically smaller than expected on the basis of alignment tensors derived from {sup 15}N-{sup 1}H amide RDCs, assuming librationally corrected N-H bond lengths of 1.041 A.

  18. Effect of alpha irradiation on UO2 surface reactivity in aqueous media

    International Nuclear Information System (INIS)

    Jegou, C.; Muzeau, B.; Broudic, V.; Poulesquen, A.; Roudil, D.; Jorion, F.; Corbel, C.

    2005-01-01

    The option of direct disposal of spent nuclear fuel in a deep geological formation raises the need to investigate the long-term behavior of the UO 2 matrix in aqueous media subjected to α-β-γ radiation. The β-γ emitters account for most of the activity of spent fuel at the moment it is removed from the reactor, but diminish within a millennial time frame by over three orders of magnitude to less than the long-term activity. The latter persists over much longer time periods and must therefore be taken into account over a geological disposal time scale. Leaching experiments with solution renewal were carried out on UO 2 pellets doped with alpha emitters ( 238 Pu and 239 Pu) to quantify the impact of alpha irradiation on UO 2 matrix alteration. Three batches of doped UO 2 pellets with different alpha flux levels (3.30 x 10 4 , 3.30 x 10 5 , and 3.2 x 10 6 α cm -2 s -1 ) were studied. The results obtained in aerated and deaerated media immediately after sample annealing or interim storage in air provide a better understanding of the UO 2 matrix alteration mechanisms under alpha irradiation. Interim storage in air of UO 2 pellets doped with alpha emitters results in variations of the UO 2 surface reactivity, which depends on the alpha particle flux at the interface and on the interim storage duration. The variation in the surface reactivity and the greater uranium release following interim storage cannot be attributed to the effect of alpha radiolysis in aerated media since the uranium release tends toward the same value after several leaching cycles for the doped UO 2 pellet batches and spent fuel. Oxygen diffusion enhanced by alpha irradiation of the extreme surface layer and/or radiolysis of the air could account for the oxidation of the surface UO 2 to UO 2+x . However, leaching experiments performed in deaerated media after annealing the samples and preleaching the surface suggest that alpha radiolysis does indeed affect the dissolution, which varies with the

  19. Optical Observations of M81 Galaxy Group in Narrow Band [SII] and H_alpha Filters: Holmberg IX

    Directory of Open Access Journals (Sweden)

    Arbutina, B.

    2009-12-01

    Full Text Available We present observations of the nearby tidal dwarf galaxy Holmberg IX in M81 galaxy group in narrow band [SII] and H$alpha$ filters, carried out in March and November 2008 with the 2m RCC telescope at NAO Rozhen, Bulgaria. Our search for resident supernova remnants (identified as sources with enhanced [SII] emission relative to their H$alpha$ emission in this galaxy yielded no sources of this kind, besides M&H 10-11 or HoIX X-1. Nevertheless, we found a number of objects with significant H$alpha$ emission that probably represent uncatalogued HII regions.

  20. Calculation of the detection efficiency in liquid scintillators. II. Single positron emitters

    International Nuclear Information System (INIS)

    Grau Malonda, A.; Garcia Torano, E.

    1982-01-01

    Counting efficiency as a function of the figure of merit for 30 positron emitters has been computed from the positron energy spectrum. Only the efficiency contribution of positrons has been taken into consideration. The contribution of the annihilation photons depending on the volume of the scintillator will be investigated in a near future. Efficiency vs figure of merit is plotted and tabulated. (Author) 19 refs

  1. Quantitative single-particle digital autoradiography with α-particle emitters for targeted radionuclide therapy using the iQID camera.

    Science.gov (United States)

    Miller, Brian W; Frost, Sofia H L; Frayo, Shani L; Kenoyer, Aimee L; Santos, Erlinda; Jones, Jon C; Green, Damian J; Hamlin, Donald K; Wilbur, D Scott; Fisher, Darrell R; Orozco, Johnnie J; Press, Oliver W; Pagel, John M; Sandmaier, Brenda M

    2015-07-01

    Alpha-emitting radionuclides exhibit a potential advantage for cancer treatments because they release large amounts of ionizing energy over a few cell diameters (50-80 μm), causing localized, irreparable double-strand DNA breaks that lead to cell death. Radioimmunotherapy (RIT) approaches using monoclonal antibodies labeled with α emitters may thus inactivate targeted cells with minimal radiation damage to surrounding tissues. Tools are needed to visualize and quantify the radioactivity distribution and absorbed doses to targeted and nontargeted cells for accurate dosimetry of all treatment regimens utilizing α particles, including RIT and others (e.g., Ra-223), especially for organs and tumors with heterogeneous radionuclide distributions. The aim of this study was to evaluate and characterize a novel single-particle digital autoradiography imager, the ionizing-radiation quantum imaging detector (iQID) camera, for use in α-RIT experiments. The iQID camera is a scintillator-based radiation detection system that images and identifies charged-particle and gamma-ray/x-ray emissions spatially and temporally on an event-by-event basis. It employs CCD-CMOS cameras and high-performance computing hardware for real-time imaging and activity quantification of tissue sections, approaching cellular resolutions. In this work, the authors evaluated its characteristics for α-particle imaging, including measurements of intrinsic detector spatial resolutions and background count rates at various detector configurations and quantification of activity distributions. The technique was assessed for quantitative imaging of astatine-211 ((211)At) activity distributions in cryosections of murine and canine tissue samples. The highest spatial resolution was measured at ∼20 μm full width at half maximum and the α-particle background was measured at a rate as low as (2.6 ± 0.5) × 10(-4) cpm/cm(2) (40 mm diameter detector area). Simultaneous imaging of multiple tissue sections was

  2. Differential labeling of platelet alpha 2 adrenoceptors by 3H dihydroergocryptine and 3H yohimbine in patients with myeloproliferative disorders

    International Nuclear Information System (INIS)

    Swart, S.S.; Wood, J.K.; Barnett, D.B.

    1985-01-01

    Platelet alpha adrenoceptor status was examined using the radioligands 3 H-yohimbine ( 3 H-YOH) and 3 H-dihydroergocryptine ( 3 H-DHE) in 14 patients with myeloproliferative disorder (MPD) and 10 normal controls. Platelets from normal controls and MPD patients sensitive to adrenaline induced aggregation exhibited approximately 50% more binding sites identified by 3 H-DHE than 3 H-YOH, whereas MPD platelets insensitive to adrenaline showed selective loss of these extra 3 H-DHE sites. In functional studies after 30 minutes preincubation with the unlabelled antagonists, DHE was more potent than YOH at inhibiting adrenaline induced aggregation in normal platelets. In addition, the affinity constant for DHE was virtually identical in binding and functional experiments, whereas for YOH the affinity constant for binding was approximately 10 fold more potent than that for aggregation. These results suggest that the alpha adrenoceptor binding site on human platelets labelled by 3 H-DHE may be of more functional relevance than that labelled by 3 H-YOH alone

  3. Effective liquid drop description for alpha decay of atomic nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Tavares, O.A.P.; Duarte, S.B. [Centro Brasileiro de Pesquisas Fisicas (CBPF), Rio de Janeiro, RJ (Brazil); Rodriguez, O.; Guzman, F. [Instituto Superior de Ciencia y Tecnologia Nuclear (ISCTN), La Habana (Cuba); Goncalves, M. [Instituto de Radioprotecao e Dosimetria (IRD), Rio de Janeiro, RJ (Brazil); Garcia, F. [Sao Paulo Univ., SP (Brazil). Inst. de Fisica

    1998-06-01

    Alpha decay half-lives are presented in the framework of an effective liquid drop model for different combination of mass transfer descriptions and inertia coefficients. Calculated half-life-values for ground-state to ground-state favoured alpha transitions are compared with available, updated experimental data. Results have shown that the present model is very suitable to treat the alpha decay process on equal foot as cluster radioactivity and cold fission processes. Better agreement with the data is found when the sub-set of even-even alpha emitters are considered in the calculation. (author) 44 refs., 5 figs., 3 tabs.; e-mail: telo at ird.gov.br

  4. Neutron coincidence counting based on time interval analysis with dead time corrected one and two dimensional Rossi-alpha distributions: an application for passive neutron waste assay

    International Nuclear Information System (INIS)

    Bruggeman, M.; Baeten, P.; De Boeck, W.; Carchon, R.

    1996-03-01

    The report describes a new neutron multiplicity counting method based on Rossi-alpha distributions. The report also gives the necessary dead time correction formulas for the multiplicity counting method. The method was tested numerically using a Monte Carlo simulation of pulse trains. The use of this multiplicity method in the field of waste assay is explained: it can be used to determine the amount of fissile material in a waste drum without prior knowledge of the actual detection efficiency

  5. 2003: A centennial of spinthariscope and scintillation counting

    International Nuclear Information System (INIS)

    Kolar, Z.I.; Hollander, W. den

    2004-01-01

    In 1903 W. Crookes demonstrated in England his 'spinthariscope' for the visual observation of individual scintillations caused by alpha particles impinging upon a ZnS screen. In contrast to the analogue methods of radiation measurements in that time the spinthariscope was a single-particle counter, being the precursor of scintillation counters since. In the same period F. Giesel, J. Elster and H. Geitel in Germany also found that scintillations from ZnS represent single particle events. This paper summarises the historical events relevant to the advent of scintillation counting

  6. Alpha radioisotopes Ac-225 and Bi-213: a production and labelling of antibodies and peptides for clinical use

    Energy Technology Data Exchange (ETDEWEB)

    Bruchertseifer, Frank, E-mail: frank.bruchertseifer@ec.europa.eu [European Commission, Joint Research Centre, Karlsruhe (Germany)

    2017-07-01

    Full text: In various preclinical and clinical works the potential of the alpha emitters {sup 225}Ac and {sup 213}Bi as therapeutic radionuclides for application in targeted alpha therapy of cancer and infectious diseases was demonstrated. Both alpha emitters are available with high specific activity from established radionuclide generators. Their favorable chemical and physical properties have led to the conduction of a large number of preclinical studies and several clinical trials, demonstrating the feasibility, safety and therapeutic efficacy of targeted alpha therapy with {sup 225}Ac and {sup 213}Bi. This presentation will give an overview about the methods for the production of {sup 225}Ac and {sup 213}Bi, the {sup 225}Ac/{sup 213}Bi radionuclide generator systems, labelling of peptides and antibodies with {sup 225}Ac and {sup 213}Bi and relevant in vivo and in vitro works. (author)

  7. A new gene deletion in the alpha-like globin gene cluster as the molecular basis for the rare alpha-thalassemia-1(--/alpha alpha) in blacks: HbH disease in sickle cell trait.

    Science.gov (United States)

    Steinberg, M H; Coleman, M B; Adams, J G; Hartmann, R C; Saba, H; Anagnou, N P

    1986-02-01

    A novel deletion of at least 26 kilobase of DNA, including both alpha-globin genes, the psi alpha- and psi zeta-globin genes, but sparing the functional zeta-gene was found in a 10-year-old black boy with HbH disease and sickle cell trait. This particular deletion has not previously been described in blacks. Its existence makes it likely that the absence of Hb Barts hydrops fetalis in blacks is due to the rarity of the chromosome lacking two alpha-globin genes rather than a result of early embryonic death due to the failure to synthesize embryonic hemoglobins because of deletion of functional zeta-globin genes.

  8. The induction of myeloid leukemia in CBA/H mice by alpha-particle emitters

    International Nuclear Information System (INIS)

    Humphreys, E.R.; Stones, V.A.

    1991-01-01

    An early experiment showed that myeloid leukemia could be induced in CBA/H mice by 224 Ra and indicated that, for a range of injected amounts of 224 Ra below that which caused a maximum yield of osteosarcoma, the incidence of myeloid leukemia was greater than that of osteosarcoma. A larger experiment set up principally to investigate this observation is now nearing completion and is confirming this early indication. Results are presented for single injection experiments and multiple injection experiments; and more recently, an investigation of the distribution and short term effects on the offspring of plutonium-239 administered to pregnant mice

  9. Assessment of the effect of probiotic curd consumption on salivary pH and streptococcus mutans counts.

    Science.gov (United States)

    Sudhir, R; Praveen, P; Anantharaj, A; Venkataraghavan, Karthik

    2012-07-01

    Antimicrobial methods of controlling dental caries that include probiotic agents can play a valuable role in establishing caries control in children at moderate to high risk for developing dental caries. Several studies have demonstrated the beneficial effects of use of various Probiotic products including curd. The objective of this study was to compare the effect of short-term consumption of probiotic curd containing Lactobacillus acidophilus and normal curd on salivary Streptococcus Mutans counts, as well as salivary pH. Forty, caries-free, 10-12 years old children were selected and randomly allocated to two groups. Test Group consisted of 20 children who consumed 200ml of probiotic curd daily for 30 days. Control Group consisted of 20 children who were given 200ml of regular curd for 30 days. Salivary pH and salivary Streptococcus Mutans counts were recorded at baseline and after 30 days and statistically compared using the Student's t-test. Consumption of probiotic curd resulted in a statistically significant reduction in S. Mutans colony counts (PpH (P>0.05) in both the groups. Short-term consumption of probiotic curds can reduce oral S. Mutans counts. However, this caused a slight reduction in salivary pH.

  10. Shielding in ungated field emitter arrays

    Energy Technology Data Exchange (ETDEWEB)

    Harris, J. R. [U.S. Navy Reserve, Navy Operational Support Center New Orleans, New Orleans, Louisiana 70143 (United States); Jensen, K. L. [Code 6854, Naval Research Laboratory, Washington, D.C. 20375 (United States); Shiffler, D. A. [Directed Energy Directorate, Air Force Research Laboratory, Albuquerque, New Mexico 87117 (United States); Petillo, J. J. [Leidos, Billerica, Massachusetts 01821 (United States)

    2015-05-18

    Cathodes consisting of arrays of high aspect ratio field emitters are of great interest as sources of electron beams for vacuum electronic devices. The desire for high currents and current densities drives the cathode designer towards a denser array, but for ungated emitters, denser arrays also lead to increased shielding, in which the field enhancement factor β of each emitter is reduced due to the presence of the other emitters in the array. To facilitate the study of these arrays, we have developed a method for modeling high aspect ratio emitters using tapered dipole line charges. This method can be used to investigate proximity effects from similar emitters an arbitrary distance away and is much less computationally demanding than competing simulation approaches. Here, we introduce this method and use it to study shielding as a function of array geometry. Emitters with aspect ratios of 10{sup 2}–10{sup 4} are modeled, and the shielding-induced reduction in β is considered as a function of tip-to-tip spacing for emitter pairs and for large arrays with triangular and square unit cells. Shielding is found to be negligible when the emitter spacing is greater than the emitter height for the two-emitter array, or about 2.5 times the emitter height in the large arrays, in agreement with previously published results. Because the onset of shielding occurs at virtually the same emitter spacing in the square and triangular arrays, the triangular array is preferred for its higher emitter density at a given emitter spacing. The primary contribution to shielding in large arrays is found to come from emitters within a distance of three times the unit cell spacing for both square and triangular arrays.

  11. Simple emittance measurement of negative hydrogen ion beam using pepper-pot method

    International Nuclear Information System (INIS)

    Hamabe, M.; Tsumori, K.; Takeiri, Y.; Kaneko, O.; Asano, E.; Kawamoto, T.; Kuroda, T.; Guharay, S.K.

    1997-01-01

    A simple apparatus for emittance measurement using pepper-pot method is developed. The pepper-pot patterns are directly exposed and recorded on a Kapton foil. Using this apparatus, emittance was measured in the case of the negative hydrogen (H - ) beam from the large negative ion source, which is the 1/3 scaled test device for the negative-ion-based neutral beam injection (N-NBI) on the Large Helical Device (LHD). As the consequence of the first trial, the 95% normalized emittance value is measured as 0.59 mm mrad. (author)

  12. Simple emittance measurement of negative hydrogen ion beam using pepper-pot method

    Energy Technology Data Exchange (ETDEWEB)

    Hamabe, M.; Tsumori, K.; Takeiri, Y.; Kaneko, O.; Asano, E.; Kawamoto, T.; Kuroda, T. [National Inst. for Fusion Science, Nagoya (Japan); Guharay, S.K.

    1997-02-01

    A simple apparatus for emittance measurement using pepper-pot method is developed. The pepper-pot patterns are directly exposed and recorded on a Kapton foil. Using this apparatus, emittance was measured in the case of the negative hydrogen (H{sup -}) beam from the large negative ion source, which is the 1/3 scaled test device for the negative-ion-based neutral beam injection (N-NBI) on the Large Helical Device (LHD). As the consequence of the first trial, the 95% normalized emittance value is measured as 0.59 mm mrad. (author)

  13. Problems and precision of the alpha scintillation radon counting system

    International Nuclear Information System (INIS)

    Lucas, H.F.; Markuu, F.

    1985-01-01

    Variations in efficiency as large as 3% have been found for radon scintillation counting systems in which the photomultiplier tubes are sensitive to the thermoluminescent photons emitted by the scintillator after exposure to light or for which the resolution has deteriorated. The additional standard deviation caused by counting a radon chamber on multiple counting systems has been evaluated and the effect, if present, did not exceed about 0.1%. The chambers have been calibrated for the measurement of radon in air, and the standard deviation was equal to statistical counting error combined with a systematic error of 1.1%. 3 references, 2 figures, 2 tables

  14. Set of counts by scintillations for atmospheric samplings; Ensemble de comptages par scintillations pour prelevements atmospheriques

    Energy Technology Data Exchange (ETDEWEB)

    Appriou, D.; Doury, A.

    1962-07-01

    The author reports the development of a scintillation-based counting assembly with the following characteristics: a photo-multiplier with a wide photo-cathode, a thin plastic scintillator for the counting of beta + alpha (and possibility of mounting an alpha scintillator), a relatively small own motion with respect to activities to be counted, a weakly varying efficiency. The authors discuss the counting objective, present equipment tests (counter, proportional amplifier and pre-amplifier, input drawer). They describe the apparatus operation, discuss the selection of scintillators, report the study of the own movement (electron-based background noise, total background noise, background noise reduction), discuss counts (influence of the external source, sensitivity to alpha radiations, counting homogeneity, minimum detectable activity) and efficiencies.

  15. Absolute measurements of the alpha-gamma emitters activities by a sum-coincidence method

    International Nuclear Information System (INIS)

    Tobias, C.C.B.

    1982-01-01

    The absolute activity of U-235 contained in a UO 2 sample, using a sum-coincidence circuit which selected only the alpha particles which were simultaneous with the well known 184 Kev gamma radiation from Th-231. The alpha particles were detected by ZnS(Ag) scintillator specially designed to show its maximun efficiency for U-235 alpha particles, whereas the gamma radiation was detected by NaI(Tl) scintillation detector. The values obtained for the half-life of U-235 was compared with data from various observers using different experimental techniques. (Author) [pt

  16. Gross alpha radioactivity of drinking water in Venezuela

    International Nuclear Information System (INIS)

    Sajo-Bohus, L.; Gomez, J.; Greaves, E.D.; Herrera, O.; Salazar, V.; Smith, A.

    1997-01-01

    Bottled mineral water is consumed by a large population in Venezuela. The alpha emitters concentration was measured in samples of bottled water and water springs collected near the surface. Approximately 30% of the total mineral water suppliers was monitored. a database on natural and artificial radioactivity in drinking water was produced. Results indicate that 54% of the waters sampled contain a total alpha radioactivity of less than 0.185 Bql -1 and only 12% above 0.37 Bql -1 . Our results revealed a total annual dose of 2.3 mSv year -1 . (author)

  17. Global determination of alpha emitters (241Am, 237Np, 239Pu, 232Th) in biological media (urine and feces)

    International Nuclear Information System (INIS)

    Bataller, Georges; Vasson, Olivier de; Bazin, Roger; Bonnard, Danielle; Morello, Marcel.

    1979-01-01

    A technique is described in this paper which permits the determination of the gross alpha activity emitted by a mixture of specially radiotoxic elements in urine and feces. After reduction and adjustment of the solution at pH 5,0, the radionuclides are adsorbed on glass marbles. The elution is made in acid medium (HCl 6N). Under these conditions the chemical yields are very satisfying: 96+-6% for urine and 68+-9% for feces. In case of significant results at the end of the manipulation, the radioactive source quality is sufficient to allow the identification of the contaminating radionuclide(s) by alpha spectrometry [fr

  18. Interferon-alpha suppressed granulocyte colony stimulating factor production is reversed by CL097, a TLR7/8 agonist.

    LENUS (Irish Health Repository)

    Tajuddin, Tariq

    2012-02-01

    BACKGROUND AND AIM: Neutropenia, a major side-effect of interferon-alpha (IFN-alpha) therapy can be effectively treated by the recombinant form of granulocyte colony stimulating factor (G-CSF), an important growth factor for neutrophils. We hypothesized that IFN-alpha might suppress G-CSF production by peripheral blood mononuclear cells (PBMCs), contributing to the development of neutropenia, and that a toll-like receptor (TLR) agonist might overcome this suppression. METHODS: Fifty-five patients who were receiving IFN-alpha\\/ribavirin combination therapy for chronic hepatitis C virus (HCV) infection were recruited. Absolute neutrophil counts (ANC), monocyte counts and treatment outcome data were recorded. G-CSF levels in the supernatants of PBMCs isolated from the patients and healthy controls were assessed by enzyme-linked immunosorbent assay following 18 h of culture in the absence or presence of IFN- alpha or the TLR7\\/8 agonist, CL097. RESULTS: Therapeutic IFN-alpha caused a significant reduction in neutrophil counts in all patients, with 15 patients requiring therapeutic G-CSF. The reduction in ANC over the course of IFN-alpha treatment was paralleled by a decrease in the ability of PBMCs to produce G-CSF. In vitro G-CSF production by PBMCs was suppressed in the presence of IFN-alpha; however, co-incubation with a TLR7\\/8 agonist significantly enhanced G-CSF secretion by cells obtained both from HCV patients and healthy controls. CONCLUSIONS: Suppressed G-CSF production in the presence of IFN-alpha may contribute to IFN-alpha-induced neutropenia. However, a TLR7\\/8 agonist elicits G-CSF secretion even in the presence of IFN-alpha, suggesting a possible therapeutic role for TLR agonists in treatment of IFN-alpha-induced neutropenia.

  19. Comparison of fusion alpha performance in JET advanced scenario and H-mode plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Asunta, O; Kurki-Suonio, T; Tala, T; Sipilae, S; Salomaa, R [JET-EFDA, Culham Science Centre, OX14 3DB, Abingdon (United Kingdom)], E-mail: Otto.Asunta@tkk.fi

    2008-12-15

    Currently, plasmas with internal transport barriers (ITBs) appear the most likely candidates for steady-state scenarios for future fusion reactors. In such plasmas, the broad hot and dense region in the plasma core leads to high fusion gain, while the cool edge protects the integrity of the first wall. Economically desirable large bootstrap current fraction and low inductive current drive may, however, lead to degraded fast ion confinement. In this work the confinement and heating profile of fusion alphas were compared between H-mode and ITB plasmas in realistic JET geometry. The work was carried out using the Monte Carlo-based guiding-center-following code ASCOT. For the same plasma current, the ITB discharges were found to produce four to eight times more fusion power than a comparable ELMy H-mode discharge. Unfortunately, also the alpha particle losses were larger ({approx}16%) compared with the H-mode discharge (7%). In the H-mode discharges, alpha power was deposited to the plasma symmetrically around the magnetic axis, whereas in the current-hole discharge, the power was spread out to a larger volume in the plasma center. This was due to wider particle orbits, and the magnetic structure allowing for a broader hot region in the centre.

  20. The WUW ML bundle detector A flow through detector for alpha-emitters

    CERN Document Server

    Wenzel, U; Lochny, M

    1999-01-01

    Using conventional laboratory ware, we designed and manufactured a flow through cell for monitoring alpha-bearing solutions. The cell consists of a bundle of thermoplastic, transparent tubes coated with a thin layer of the meltable scintillator MELTILEX sup T sup M at the inner surface. With appropriate energy windows set, the detector can suppress beta-particles to a great extent due to its geometrical dimensions. For pure alpha-solutions, the detection limits are 5 Bq/ml, for composite nuclide mixtures, the detector is capable to monitor the decontamination of medium active waste (<=10 sup 7 Bq/ml) down to 100 Bq alpha/g solution. At a throughput of 1 ml/s, the pressure build-up amounts to approx 2 bar. We have developed a quality control program to ensure the regularity of the individual bundle loops.

  1. Deconvolution of H-alpha profiles measured by Thompson scattering collecting optics

    International Nuclear Information System (INIS)

    LeBlanc, B.; Grek, B.

    1986-01-01

    This paper discusses that optically fast multichannel Thomson scattering optics that can be used for H-alpha emission profile measurement. A technique based on the fact that a particular volume element of the overall field of view can be seen by many channels, depending on its location, is discussed. It is applied to measurement made on PDX with the vertically viewing TVTS collecting optics (56 channels). The authors found that for this case, about 28 Fourier modes are optimum to represent the spatial behavior of the plasma emissivity. The coefficients for these modes are obtained by doing a least-square-fit to the data subjet to certain constraints. The important constraints are non-negative emissivity, the assumed up and down symmetry and zero emissivity beyond the liners. H-alpha deconvolutions are presented for diverted and circular discharges

  2. Fission- and alpha-track study of biogeochemistry of plutonium and uranium in carbonates of Bikini and Enewetak atolls. Progress report, January 1, 1976--December 31, 1976

    International Nuclear Information System (INIS)

    Levy, Y.; Miller, D.S.; Friedman, G.M.

    1976-09-01

    Alpha emitters have been detected with a resolution of a few tens of micrometers using a solid state track detector (cellulose nitrate) to map the activity in a coral sample from Bikini. Calibration methods used include: a Pu source of 0.15 μCi in conjunction with polycarbonate and CaCO 3 absorbers of different thicknesses (2 to 30 micrometers), and a powdered coral sample which had been analyzed previously for alpha emitters by chemical methods in conjunction with an alpha spectrometer. 0.04 mm 3 can be measured routinely; smaller concentrations can be determined but with a lower resolution. CaCO 3 of the coral Favites virens from Bikini lagoon was analyzed by placing the detector directly on the sample for thirty days. Sections and thin sections cut perpendicular to one another, but parallel to the direction of coral growth, give very different concentrations and distributions of alpha emitters. Maximum concentrations of 800 pCi/g were measured in a volume of 0.004 mm 3 in void-filling cement separated from the coral and in an area in which coral skeleton and cement could not be distinguished. Areas of high alpha emitter concentrations coincide with areas of coral growth interruption where non coral material exists that is composed of a mixture of encrusting bryozoan like carbonate material and skeletal debris

  3. Micro-precipitation of Americium by Cerium Hydroxide for alpha spectrometry

    International Nuclear Information System (INIS)

    Wankhede, Sonal M.; Kumar, Suja A.; Sawant, Pramilla D.

    2018-01-01

    Estimation of trace amount of actinides in any biological and/or environmental sample is done by radiochemical separation followed by alpha spectrometry. Alpha-spectrometric determination of actinides requires thin, homogeneous and nearly weightless sample sources. The most widely used method for preparation of actinides for alpha spectrometry involves electro deposition of the alpha emitters using stainless steel planchetts (cathode) and platinum rod (anode). This procedure is time consuming, requires relatively elaborate equipment, and is expensive. Micro-precipitation technique using hydrofluoric acid (HF) is also reliable and already standardized at Bioassay Laboratory (Wankhede, 2016). However, it uses hazardous chemical such as HF, hence, in the present study, cerium hydroxide micro-precipitation technique was standardized

  4. DISCOVERY OF AN H{alpha} EMITTING DISK AROUND THE SUPERMASSIVE BLACK HOLE OF M31

    Energy Technology Data Exchange (ETDEWEB)

    Menezes, R. B.; Steiner, J. E.; Ricci, T. V., E-mail: robertobm@astro.iag.usp.br [Instituto de Astronomia Geofisica e Ciencias Atmosfericas, Universidade de Sao Paulo, Rua do Matao 1226, Cidade Universitaria, Sao Paulo, SP CEP 05508-090 (Brazil)

    2013-01-10

    Due to its proximity, the mass of the supermassive black hole in the nucleus of the Andromeda galaxy (M31), the most massive black hole in the Local Group of galaxies, has been measured by several methods involving the kinematics of a stellar disk which surrounds it. We report here the discovery of an eccentric H{alpha} emitting disk around the black hole at the center of M31 and show how modeling this disk can provide an independent determination of the mass of the black hole. Our model implies a mass of 5.0{sup +0.8}{sub -1.0} Multiplication-Sign 10{sup 7} M{sub Sun} for the central black hole, consistent with the average of determinations by methods involving stellar dynamics, and compatible (at 1{sigma} level) with measurements obtained from the most detailed models of the stellar disk around the central black hole. This value is also consistent with the M-{sigma} relation. In order to make a comparison, we applied our simulation on the stellar kinematics in the nucleus of M31 and concluded that the parameters obtained for the stellar disk are not formally compatible with the parameters obtained for the H{alpha} emitting disk. This result suggests that the stellar and the H{alpha} emitting disks are intrinsically different from each other. A plausible explanation is that the H{alpha} emission is associated with a gaseous disk. This hypothesis is supported by the detection of traces of weaker nebular lines in the nuclear region of M31. However, we cannot exclude the possibility that the H{alpha} emission is, at least partially, generated by stars.

  5. FIRST SIMULTANEOUS OBSERVATION OF AN H{alpha} MORETON WAVE, EUV WAVE, AND FILAMENT/PROMINENCE OSCILLATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Asai, Ayumi; Isobe, Hiroaki [Unit of Synergetic Studies for Space, Kyoto University, Yamashina, Kyoto 607-8471 (Japan); Ishii, Takako T.; Kitai, Reizaburo; Ichimoto, Kiyoshi; UeNo, Satoru; Nagata, Shin' ichi; Morita, Satoshi; Nishida, Keisuke; Shibata, Kazunari [Kwasan and Hida Observatories, Kyoto University, Yamashina, Kyoto 607-8471 (Japan); Shiota, Daikou [Advanced Science Institute, RIKEN, Wako, Saitama 351-0198 (Japan); Oi, Akihito [College of Science, Ibaraki University, Mito, Ibaraki 310-8512 (Japan); Akioka, Maki, E-mail: asai@kwasan.kyoto-u.ac.jp [Hiraiso Solar Observatory, National Institute of Information and Communications Technology, Hitachinaka, Ibaraki 311-1202 (Japan)

    2012-02-15

    We report on the first simultaneous observation of an H{alpha} Moreton wave, the corresponding EUV fast coronal waves, and a slow and bright EUV wave (typical EIT wave). We observed a Moreton wave, associated with an X6.9 flare that occurred on 2011 August 9 at the active region NOAA 11263, in the H{alpha} images taken by the Solar Magnetic Activity Research Telescope at Hida Observatory of Kyoto University. In the EUV images obtained by the Atmospheric Imaging Assembly on board the Solar Dynamic Observatory we found not only the corresponding EUV fast 'bright' coronal wave, but also the EUV fast 'faint' wave that is not associated with the H{alpha} Moreton wave. We also found a slow EUV wave, which corresponds to a typical EIT wave. Furthermore, we observed, for the first time, the oscillations of a prominence and a filament, simultaneously, both in the H{alpha} and EUV images. To trigger the oscillations by the flare-associated coronal disturbance, we expect a coronal wave as fast as the fast-mode MHD wave with the velocity of about 570-800 km s{sup -1}. These velocities are consistent with those of the observed Moreton wave and the EUV fast coronal wave.

  6. Rapid determination of radium-224/226 in seawater sample by alpha spectrometry.

    Science.gov (United States)

    Song, Lijuan; Yang, Yonggang; Luo, Maoyi; Ma, Yan; Dai, Xiongxin

    2017-05-01

    A new radiochemical separation method has been developed for rapid determination of alpha-emitting radium isotopes in seawater samples. This method can be applied for the measurement of 226 Ra in seawater samples when 224 Ra is used as tracer for chemical recovery correction. Likewise, 226 Ra can also be added as tracer for the determination of 224 Ra in seawater sample. In the method, radium is first pre-concentrated with hydrous titanium oxide (HTiO) and is purified by combined anion/cation exchange column chromatographic separation. The radium in the eluate is then co-precipitated with HTiO, dissolved in 9 M H 2 SO 4 , and followed through a BaSO 4 micro-precipitation step to prepare a thin-layer counting source to determine the activities of 224 Ra/ 226 Ra by alpha spectrometry. Replicate spike and blank samples were measured to evaluate the performance of the procedure. The minimum detectable activity concentration was determined to be 0.5 mBq·L -1 for 226 Ra and 0.4 mBq·L -1 for 224 Ra in 1 L of seawater sample with a counting time of 48 h. The method is a promising candidate for rapid measurement for alpha-emitting Ra isotopes in a large population of environment water samples. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Large area gridded ionisation chamber and electrostatic precipitator. Application to low-level alphaspectrometry of environmental air samples

    International Nuclear Information System (INIS)

    Hoetzl, H.; Winkler, R.

    1978-01-01

    A high-resolution, parallel plate Frisch grid ionisation chamber with an efficient area of 300 cm 2 and a large area electrostatic precipitator were developed and applied to direct alpha-particle spectrometry of air dust. The aerosols were deposited on circular tin-plate dishes of 300 cm 2 by the electrostatic precipitator, which was constructed for continuous operation at an air flow rate of 2 m 3 /h. Collection efficiency is found to be 0.78 for the natural Rn- and Tn-daughter products. Using an argon-methane mixture (P-10 gas) at atmospheric pressure, the resolution of the detector system is 22 keV fwhm at 5.15 MeV. The integral background is typically 15.7 counts/h between 4 and 6 MeV. After sampling for one week and decay of short-lived natural activity, the sensitivity of the procedure for long-lived alpha-emitters is about 0.1 fCi/m 3 based on 3s of background as detection limit and 1000 min counting time. (Auth.)

  8. Electrically-driven GHz range ultrafast graphene light emitter (Conference Presentation)

    Science.gov (United States)

    Kim, Youngduck; Gao, Yuanda; Shiue, Ren-Jye; Wang, Lei; Aslan, Ozgur Burak; Kim, Hyungsik; Nemilentsau, Andrei M.; Low, Tony; Taniguchi, Takashi; Watanabe, Kenji; Bae, Myung-Ho; Heinz, Tony F.; Englund, Dirk R.; Hone, James

    2017-02-01

    Ultrafast electrically driven light emitter is a critical component in the development of the high bandwidth free-space and on-chip optical communications. Traditional semiconductor based light sources for integration to photonic platform have therefore been heavily studied over the past decades. However, there are still challenges such as absence of monolithic on-chip light sources with high bandwidth density, large-scale integration, low-cost, small foot print, and complementary metal-oxide-semiconductor (CMOS) technology compatibility. Here, we demonstrate the first electrically driven ultrafast graphene light emitter that operate up to 10 GHz bandwidth and broadband range (400 1600 nm), which are possible due to the strong coupling of charge carriers in graphene and surface optical phonons in hBN allow the ultrafast energy and heat transfer. In addition, incorporation of atomically thin hexagonal boron nitride (hBN) encapsulation layers enable the stable and practical high performance even under the ambient condition. Therefore, electrically driven ultrafast graphene light emitters paves the way towards the realization of ultrahigh bandwidth density photonic integrated circuits and efficient optical communications networks.

  9. Current status of liquid scintillation counting

    International Nuclear Information System (INIS)

    Klingler, G.W.

    1981-01-01

    Scintillation counting of alpha particles has been used since the turn of the century. The advent of pulse shape discrimination has made this method of detection accurate and reliable. The history, concepts and development of scintillation counting and pulse shape discrimination are discussed. A brief look at the ongoing work in the consolidation of components now used for pulse shape discrimination is included

  10. Accumulation of glycation products in. cap alpha. -H pig lens crystallin and its bearing to diabetic cataract genesis

    Energy Technology Data Exchange (ETDEWEB)

    Vidal, P; Cabezas-Cerrato, J

    1988-01-01

    The incorporation of /sup 11/C-glucose in native pig crystalline by in vitro incubation was found, after subsequent dialysis, to affect all 5 classes of crystallin separated by Sepharose CL-6B column chromatography. Though the radioactivity of the ..cap alpha..-H fraction was three times greater than that of any of the others, autoradiographs of SDS-PAGE gels showed /sup 11/C-glucose adducts to be present in all soluble protein subunits, without there being any evidence of preferential glycation of the ..cap alpha..-H subunits. The concentration of stable glycation products in the ..cap alpha..-H chromatographic fraction of soluble crystallins is suggested to be due the addition of glycated material to this fraction as result of glycation-induced hyperaggregation, and not because the ..cap alpha..-H subunits were especially susceptible to glycation.

  11. Overview of laserwire beam profile and emittance measurements for high power proton accelerators

    CERN Document Server

    Gibson, S M; Bosco, A; Gabor, C; Pozimski, J; Savage, P; Hofmann, T

    2013-01-01

    Laserwires were originally developed to measure micron-sized electron beams via Compton scattering, where traditional wire scanners are at the limit of their resolution. Laserwires have since been applied to larger beamsize, high power H$^-$ ion beams, where the non-invasive method can probe beam densities that would damage traditional diagnostics. While photo-detachment of H$^-$ ions is now routine to measure beam profiles, extending the technique to transverse and longitudinal emittance measurements is a key aim of the laserwire emittance scanner under construction at the Front End Test Stand (FETS) at the RAL. A pulsed, 30 kHz, 8kW peak power laser is fibrecoupled to motorized collimating optics, which controls the position and thickness of the laserwire delivered to the H- interaction chamber. The laserwire slices out a beamlet of neutralized particles, which propagate to a downstream scintillator and camera. The emittance is reconstructed from 2D images as the laserwire position is scanned. Results from ...

  12. Determination of plutonium-241 by liquid scintillation counting method and its application to environmental samples

    International Nuclear Information System (INIS)

    Watanabe, Miki; Amano, Hikaru

    1997-03-01

    Radionuclides are usually measured by gross counting mode in liquid scintillator counting (LSC) which measures both α and β pulses. This method can easily measure radioactivities, but its background counting is high. Recently reported α-β pulse shape discrimination method (α-β PSD method) in LSC which distinguishes α pulses from β pulses, shows low background counting, so it makes the detection limit lower. The aim of this research is to develop the best method for the determination of 241 Pu which is β-emitter, and Pu isotopes of α-emitters which have long half-lives and stay long in animal body. In this research, two LSC machines was carried out in different scintillators, vial volumes, measurement modes and so on. The following things were found. 1. The liquid scintillator based on naphthalene is proved to be the best separator of α-ray from β-ray, because it acts quickly in energy translation procedure between solvent and aromatic compounds. 2. α-β PSD method makes the background counting rate ten times lower than usual method. It makes the measurement performance better. 3. It is possible to determine 241 Pu in environmental samples around Chernobyl by the combination of LSC and radiochemical separation methods. (author)

  13. Demonstration of specific binding sites for 3H-RRR-alpha-tocopherol on human erythrocytes

    International Nuclear Information System (INIS)

    Kitabchi, A.E.; Wimalasena, J.

    1982-01-01

    Previous work from our laboratory demonstrated specific binding sites for 3 H-RRR-alpha-tocopherol ( 3 H-d alpha T) in membranes of rat adrenal cells. As tocopherol deficiency is associated with increased susceptibility of red blood cells to hemolysis, we investigated tocopherol binding sites in human RBCs. Erythrocytes were found to have specific binding sites for 3 H-d alpha T that exhibited saturability and time and cell-concentration dependence as well as reversibility of binding. Kinetic studies of binding demonstrated two binding sites--one with high affinity (Ka of 2.6 x 10(7) M-1), low capacity (7,600 sites per cell) and the other with low affinity (1.2 x 10(6) M-1), high capacity (150,000 sites per cell). In order to localize the binding sites further, RBCs were fractionated and greater than 90% of the tocopherol binding was located in the membranes. Similar to the findings in intact RBCs, the membranes exhibited two binding sites with a respective Ka of 3.3 x 10(7) M-1 and 1.5 x 10(6) M-1. Specificity data for binding demonstrated 10% binding for RRR-gamma-tocopherol, but not other tocopherol analog exhibited competition for 3 H-d alpha T binding sites. Instability data suggested a protein nature for these binding sites. Preliminary studies on Triton X-100 solubilized fractions resolved the binding sites to a major component with an Mr of 65,000 and a minor component with an Mr of 125,000. We conclude that human erythrocyte membranes contain specific binding sites for RRR-alpha-tocopherol. These sites may be of physiologic significance in the function of tocopherol on the red blood cell membrane

  14. Monolithic multinozzle emitters for nanoelectrospray mass spectrometry

    Science.gov (United States)

    Wang, Daojing [Daly City, CA; Yang, Peidong [Kensington, CA; Kim, Woong [Seoul, KR; Fan, Rong [Pasadena, CA

    2011-09-20

    Novel and significantly simplified procedures for fabrication of fully integrated nanoelectrospray emitters have been described. For nanofabricated monolithic multinozzle emitters (NM.sup.2 emitters), a bottom up approach using silicon nanowires on a silicon sliver is used. For microfabricated monolithic multinozzle emitters (M.sup.3 emitters), a top down approach using MEMS techniques on silicon wafers is used. The emitters have performance comparable to that of commercially-available silica capillary emitters for nanoelectrospray mass spectrometry.

  15. Investigating proton emitters at the limits of stability with radioactive beams from the Oak Ridge facility

    Energy Technology Data Exchange (ETDEWEB)

    Toth, K.S. [Oak Ridge National Lab., TN (United States); Batchelder, J.C.; Zganjar, E.F. [Louisiana State Univ., Baton Rouge, LA (United States); Bingham, C.R.; Wauters, J. [Tennessee Univ., Knoxville, TN (United States); Davinson, T.; MacKenzie, J.A.; Woods, P.J. [Edinburgh Univ. (United Kingdom)

    1996-10-01

    By using beams from the Holifield Radioactive Ion Beam Facility at ORNL, it should be possible to identify many new ground-state proton emitters in the mass region from Sn to Pb. In these investigations nuclei produced in fusion-evaporation reactions will be separated from incident ions and dispersed in mass/charge with a recoil mass separator and then implanted into a double-sided Si strip detector for study of proton (and {alpha}-particle) radioactivity. This paper summarizes data presently extant on proton emitters and then focuses on tests and initial experiments that will be carried out with stable beams and with radioactive ions as they are developed at the Oak Ridge facility.

  16. Demonstration of a laserwire emittance scanner for hydrogen ion beams at CERN

    CERN Document Server

    Hofmann, Thomas; Bosco, A.; Gibson, S.M.; Roncarolo, F.; Boorman, G.; Raich, U.; Bravin, E.; Pozimski, J.K.; Letchford, A.; Gabor, C.

    2015-12-21

    A non-invasive, compact laserwire system has been developed to measure the transverse emittance of an H- beam and has been demonstrated at the new LINAC4 injector for the LHC at CERN. Light from a low power, pulsed laser source is conveyed via fibre to collide with the H- beam, a fraction of which is neutralized and then intercepted by a downstream diamond detector. Scanning the focused laser across the H- beam and measuring the distribution of the photo-neutralized particles enables the transverse emittance to be reconstructed. The vertical phase-space distribution of a 3 MeV beam during LINAC4 commissioning has been measured by the laserwire and verified with a conventional slit and grid method.

  17. High-Precision Half-life Measurements for the Superallowed β+ Emitter 14O

    Science.gov (United States)

    Laffoley, A. T.; Svensson, C. E.; Andreoiu, C.; Austin, R. A. E.; Ball, G. C.; Blank, B.; Bouzomita, H.; Cross, D. S.; Diaz Varela, A.; Dunlop, R.; Finlay, P.; Garnsworthy, A. B.; Garrett, P. E.; Giovinazzo, J.; Grinyer, G. F.; Hackman, G.; Hadinia, B.; Jamieson, D. S.; Ketelhut, S.; Leach, K. G.; Leslie, J. R.; Tardiff, E. R.; Thomas, J. C.; Unsworth, C.

    2014-03-01

    The half-life of 14O, a superallowed Fermi β+ emitter, has been determined via simultaneous γ and β counting experiments at TRIUMF's Isotope Separator and Accelerator facility. Following the implantation of 14O samples at the center of the 8π spectrometer, a γ counting measurement was performed by detecting the 2313 keV γ-rays emitted from the first excited state of the daughter 14N using 20 high-purity germanium (HPGe) detectors. A simultaneous β counting experiment was performed using a fast plastic scintillator positioned directly behind the implantation site. The results, T½(γ) = 70:632 ± 0:094 s and T½(β) = 70:610 ± 0:030 s, are consistent with one another and, together with eight previous measurements, establish a new average for the 14O half-life of T½ = 70:619 ± 0:011 s with a reduced χ2 of 0.99.

  18. High emittance black nickel coating on copper substrate for space applications

    Energy Technology Data Exchange (ETDEWEB)

    Somasundaram, Soniya, E-mail: jrf0013@isac.gov.in; Pillai, Anju M., E-mail: anjum@isac.gov.in; Rajendra, A., E-mail: rajendra@isac.gov.in; Sharma, A.K., E-mail: aks@isac.gov.in

    2015-09-15

    Highlights: • High emittance black nickel coating is obtained on copper substrate. • The effect of various process parameters on IR emittance is studied systematically. • Process parameters are optimized to develop a high emittance black nickel coating. • Coating obtained using the finalized parameters exhibited an emittance of 0.83. • SEM and EDAX are used for coating characterization. - Abstract: Black nickel, an alloy coating of zinc and nickel, is obtained on copper substrate by pulse electrodeposition from a modified Fishlock bath containing nickel sulphate, nickel ammonium sulphate, zinc sulphate and ammonium thiocyanate. A nickel undercoat of 4–5 μm thickness is obtained using Watts bath to increase the corrosion resistance and adhesion of the black nickel coating. The effect of bath composition, temperature, solution pH, current density and plating time on the coating appearance and corresponding infra-red emittance of the coating is investigated systematically. Process parameters are optimized to develop a high emittance space worthy black nickel coating to improve the heat radiation characteristics. The effect of the chemistry of the plating bath on the coating composition was studied using energy dispersive X-ray analysis (EDAX) of the coatings. The 5–6 μm thick uniform jet black zinc–nickel alloy coating obtained with optimized process exhibited an emittance of 0.83 and an absorbance of 0.92. The zinc to nickel ratio of black nickel coatings showing high emittance and appealing appearance was found to be in the range 2.3–2.4.

  19. Characterization of the human pH- and PKA-activated ClC-2G(2 alpha) Cl- channel.

    Science.gov (United States)

    Sherry, A M; Stroffekova, K; Knapp, L M; Kupert, E Y; Cuppoletti, J; Malinowska, D H

    1997-08-01

    A ClC-2G(2 alpha) Cl- channel was identified to be present in human lung and stomach, and a partial cDNA for this Cl- channel was cloned from a human fetal lung library. A full-length expressible human ClC-2G(2 alpha) cDNA was constructed by ligation of mutagenized expressible rabbit ClC-2G(2 alpha) cDNA with the human lung ClC-2G(2 alpha) cDNA, expressed in oocytes, and characterized at the single-channel level. Adenosine 3',5'-cyclic monophosphate-dependent protein kinase (PKA) treatment increased the probability of opening of the channel (Po). After PKA activation, the channel exhibited a linear (r = 0.99) current-voltage curve with a slope conductance of 22.1 +/- 0.8 pS in symmetric 800 mM tetraethylammonium chloride (TEACl; pH 7.4). Under fivefold gradient conditions of TEACl, a reversal potential of +21.5 +/- 2.8 mV was measured demonstrating anion-to-cation discrimination. As previously demonstrated for the rabbit ClC-2G(2 alpha) Cl- channel, the human analog, hClC-2G(2 alpha), was active at pH 7.4 as well as when the pH of the extracellular face of the channel (trans side of the bilayer; pHtrans) was asymmetrically reduced to pH 3.0. The extent of PKA activation was dependent on pHtrans. With PKA treatment, Po increased fourfold with a pHtrans of 7.4 and eightfold with a pHtrans of 3.0. Effects of sequential PKA addition followed by pHtrans reduction on the same channel suggested that the PKA- and pH-dependent increases in channel Po were separable and cumulative. Northern analysis showed ClC-2G(2 alpha) mRNA to be present in human adult and fetal lung and adult stomach, and quantitative reverse transcriptase-polymerase chain reaction showed this channel to be present in the adult human lung and stomach at about one-half the level found in fetal lung. The findings of the present study suggest that the ClC-2G(2 alpha) Cl- channel may play an important role in Cl- transport in the fetal and adult human lung.

  20. Report of a Technical Meeting on ''Alpha emitting radionuclides and radiopharmaceuticals for therapy''

    International Nuclear Information System (INIS)

    2013-01-01

    Considering the high potential of α-emitters for future development of radionuclide therapy, the International Atomic Energy Agency (IAEA) organized a Technical Meeting on ‘Alpha Emitting Radionuclides and Radiopharmaceuticals for Therapy’, from June 24 to 28, 2013, at IAEA Headquarters in Vienna with the purpose of gathering eminent Experts in the field and discuss with them the status and future perspectives of the field. Sixteen Experts and two External Observers from ten different countries, and four IAEA Technical Officers attended this meeting. Outstanding lectures have been presented covering all relevant aspects of α-therapy, which were followed by extensive discussions and analysis. Selected arguments encompassed production methods and availability of alpha-emitting radionuclides, labelling chemistry of alpha-emittting radioelements, design and development of target-specific radiopharmaceuticals, physical principles of alpha-particle dosimetry and advanced dosimetric models, biological effects of alpha radiation at the cellular level, on-going preclinical and clinical studies with new radiopharmaceuticals, results of clinical trials on the use of radium-223 chloride solutions for the treatment of metastatic bone cancer. The broad scientific background of invited components of the Experts’ panel conferred a strong interdisciplinary trait to the overall discussion and stimulated a critical analysis of this emerging unexplored field. Results of this comprehensive overview on alpha therapy, including recommendations to the Agency on suitable initiatives that may help to promote and spread the knowledge to Members States on this emerging therapeutic modality, are summarized in the present Report

  1. Validation the quantification of beta emitters activity in urine by scintillation spectrometry in the liquid phase; Validacion de la cuantificacion de actividad de emisores beta en orina mediante espectrometria de centelleo en fase liquida

    Energy Technology Data Exchange (ETDEWEB)

    Sierra, I.; Hernandez, C.; Benito, P.; Lopez, C.

    2013-07-01

    In this paper the methodology used in the validation of the technique for quantifying activity of some beta emitters in urine ({sup 3}H, {sup 1}4C, {sup 3}5S, {sup 3}2P and {sup 9}0Sr) by scintillation spectrometry Liquid Phase (Liquid Scintillation Counting, LSC) is described in bio elimination Laboratory Service CIEMAT Radiation Dosimetry accredited since last year for carrying out assays measure radiation dose based on ISO forth above. (Author)

  2. Synthesis of tritiated 1-alpha-methadol and 1-alpha-acetylmethadol

    Energy Technology Data Exchange (ETDEWEB)

    Thang, D.C.; Nam, N.H.; Pontikis, R. (Institut National de la Sante et de la Recherche Medicale (INSERM), Hopital Fernand Widal, 75 - Paris (France)); Pichat, L. (CEA Centre d' Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France). Service des Molecules Marquees)

    1982-04-01

    dl-Methadone was resolved by crystallization of its ammonium d- ..cap alpha.. -bromocamphor-..pi..-sulfonate salt to give d-methadone. The latter in ethyl acetate solution was reduced with tritium gas to 1-..cap alpha..-methadol /sup 3/H in presence of Adams platinum oxide at normal temperature and pressure. Acetylation of 1-..cap alpha..-carbinol hydrochloride by means of acetyl chloride afforded 1-..cap alpha..-acetylmethadol /sup 3/H, specific activity: 20 Ci/mMole. The positions and extent of tritium labelling were determined by /sup 3/H NMR spectroscopy.

  3. FACET Emittance Growth

    Energy Technology Data Exchange (ETDEWEB)

    Frederico, J; Hogan, M.J.; Nosochkov, Y.; Litos, M.D.; Raubenheimer, T.; /SLAC

    2011-04-05

    FACET, the Facility for Advanced Accelerator and Experimental Tests, is a new facility being constructed in sector 20 of the SLAC linac primarily to study beam driven plasma wakefield acceleration. The FACET beamline consists of a chicane and final focus system to compress the 23 GeV, 3.2 nC electron bunches to {approx}20 {micro}m long and {approx}10 {micro}m wide. Simulations of the FACET beamline indicate the short-duration and large, 1.5% rms energy spread beams may suffer a factor of four emittance growth from a combination of chromaticity, incoherent synchrotron radiation (ISR), and coherent synchrotron radiation (CSR). Emittance growth is directly correlated to head erosion in plasma wakefield acceleration and is a limiting factor in single stage performance. Studies of the geometric, CSR, and ISR components are presented. Numerical calculation of the rms emittance can be overwhelmed by long tails in the simulated phase space distributions; more useful definitions of emittance are given. A complete simulation of the beamline is presented as well, which agrees with design specifications.

  4. FACET Emittance Growth

    International Nuclear Information System (INIS)

    Frederico, Joel

    2011-01-01

    FACET, the Facility for Advanced Accelerator and Experimental Tests, is a new facility being constructed in sector 20 of the SLAC linac primarily to study beam driven plasma wakefield acceleration. The FACET beamline consists of a chicane and final focus system to compress the 23 GeV, 3.2 nC electron bunches to ∼20 (micro)m long and ∼10 (micro)m wide. Simulations of the FACET beamline indicate the short-duration and large, 1.5% rms energy spread beams may suffer a factor of four emittance growth from a combination of chromaticity, incoherent synchrotron radiation (ISR), and coherent synchrotron radiation (CSR). Emittance growth is directly correlated to head erosion in plasma wakefield acceleration and is a limiting factor in single stage performance. Studies of the geometric, CSR, and ISR components are presented. Numerical calculation of the rms emittance can be overwhelmed by long tails in the simulated phase space distributions; more useful definitions of emittance are given. A complete simulation of the beamline is presented as well, which agrees with design specifications.

  5. Recovering the triple coincidence of non-pure positron emitters in preclinical PET

    Science.gov (United States)

    Lin, Hsin-Hon; Chuang, Keh-Shih; Chen, Szu-Yu; Jan, Meei-Ling

    2016-03-01

    Non-pure positron emitters, with their long half-lives, allow for the tracing of slow biochemical processes which cannot be adequately examined by the commonly used short-lived positron emitters. Most of these isotopes emit high-energy cascade gamma rays in addition to positron decay that can be detected and create a triple coincidence with annihilation photons. Triple coincidence is discarded in most scanners, however, the majority of the triple coincidence contains true photon pairs that can be recovered. In this study, we propose a strategy for recovering triple coincidence events to raise the sensitivity of PET imaging for non-pure positron emitters. To identify the true line of response (LOR) from a triple coincidence, a framework utilizing geometrical, energy and temporal information is proposed. The geometrical criterion is based on the assumption that the LOR with the largest radial offset among the three sub pairs of triple coincidences is least likely to be a true LOR. Then, a confidence time window is used to test the valid LOR among those within triple coincidence. Finally, a likelihood ratio discriminant rule based on the energy probability density distribution of cascade and annihilation gammas is established to identify the true LOR. An Inveon preclinical PET scanner was modeled with GATE (GEANT4 application for tomographic emission) Monte Carlo software. We evaluated the performance of the proposed method in terms of identification fraction, noise equivalent count rates (NECR), and image quality on various phantoms. With the inclusion of triple coincidence events using the proposed method, the NECR was found to increase from 11% to 26% and 19% to 29% for I-124 and Br-76, respectively, when 7.4-185 MBq of activity was used. Compared to the reconstructed images using double coincidence, this technique increased the SNR by 5.1-7.3% for I-124 and 9.3-10.3% for Br-76 within the activity range of 9.25-74 MBq, without compromising the spatial resolution or

  6. Treatment of alpha bearing wastes

    International Nuclear Information System (INIS)

    1988-01-01

    This report deals with the current state of the art of alpha waste treatment, which is an integral part of the overall nuclear waste management system. The International Atomic Energy Agency (IAEA) defines alpha bearing waste as 'waste containing one or more alpha emitting radionuclides, usually actinides, in quantities above acceptable limits'. The limits are established by national regulatory bodies. The limits above which wastes are considered as alpha contaminated refer to the concentrations of alpha emitters that need special consideration for occupational exposures and/or potential safety, health, or environmental impact during one or more steps from generation through disposal. Owing to the widespread use of waste segregation by source - that is, based upon the 'suspect origin' of the material - significant volumes of waste are being handled as alpha contaminated which, in fact, do not require such consideration by reason of risk or environmental concern. The quantification of de minimis concepts by national regulatory bodies could largely contribute to the safe reduction of waste volumes and associated costs. Other factors which could significantly contribute to the reduction of alpha waste arisings are an increased application of assaying and sorting, instrumentation and the use of feedback mechanisms to control or modify the processes which generate these wastes. Alpha bearing wastes are generated during fabrication and reprocessing of nuclear fuels, decommissioning of alpha contaminated facilities, and other activities. Most alpha wastes are contact handled, but a small portion may require shielding or remote handling because of high levels of neutron (n), beta (β), or gamma (γ) emissions associated with the waste material. This report describes the sources and characteristics of alpha wastes and strategies for alpha waste management. General descriptions of treatment processes for solid and liquid alpha wastes are included. 71 refs, 14 figs, 9 tabs

  7. Crystalline anhydrous {alpha},{alpha}-trehalose (polymorph {beta}) and crystalline dihydrate {alpha},{alpha}-trehalose: A calorimetric study

    Energy Technology Data Exchange (ETDEWEB)

    Pinto, Susana S. [Centro de Quimica Estrutural, Complexo Interdisciplinar, Instituto Superior Tecnico, 1049-001 Lisbon (Portugal)]. E-mail: susanapinto@ist.utl.pt; Diogo, Herminio P. [Centro de Quimica Estrutural, Complexo Interdisciplinar, Instituto Superior Tecnico, 1049-001 Lisbon (Portugal)]. E-mail: hdiogo@ist.utl.pt; Moura-Ramos, Joaquim J. [Centro de Quimica-Fisica Molecular, Complexo Interdisciplinar, Instituto Superior Tecnico, 1049-001 Lisbon (Portugal)]. E-mail: mouraramos@ist.utl.pt

    2006-09-15

    The mean values of the standard massic energy of combustion of crystalline anhydrous {alpha},{alpha}-trehalose (C{sub 12}H{sub 22}O{sub 11}, polymorph {beta}) and crystalline dihydrate {alpha},{alpha}-trehalose (C{sub 12}H{sub 26}O{sub 13}) measured by static-bomb combustion calorimetry in oxygen, at the temperature T=298.15K, are {delta}{sub c}u{sup o}=-(16434.05+/-4.50)J.g{sup -1} and {delta}{sub c}u{sup o}=-(14816.05+/-3.52)J.g{sup -1}, respectively. The standard (p{sup o}=0.1MPa) molar enthalpy of formation of these compounds were derived from the corresponding standard molar enthalpies of combustion, respectively, {delta}{sub f}H{sub m}{sup o} (C{sub 12}H{sub 22}O{sub 11},cr)=-(2240.9+/-3.9)kJ.mol{sup -1}, and {delta}{sub f}H{sub m}{sup o} (C{sub 12}H{sub 26}O{sub 13},cr)=-(2832.6+/-3.6)kJ.mol{sup -1}. The values of the standard enthalpies of formation obtained in this work, together with data on enthalpies of solution at infinite dilution ({delta}{sub sol}H{sup {approx}}) for crystalline dihydrate and amorphous anhydrous trehalose, allow a better insight on the thermodynamic description of the trehalose system which can provide, together with the future research on the subject, a contribution for understanding the metabolism in several organisms, as well as the phase transition between the different polymorphs.

  8. Quantitative single-particle digital autoradiography with α-particle emitters for targeted radionuclide therapy using the iQID camera

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Brian W., E-mail: brian.miller@pnnl.gov [Pacific Northwest National Laboratory, Richland, Washington 99354 and College of Optical Sciences, The University of Arizona, Tucson, Arizona 85719 (United States); Frost, Sofia H. L.; Frayo, Shani L.; Kenoyer, Aimee L.; Santos, Erlinda; Jones, Jon C.; Orozco, Johnnie J. [Fred Hutchinson Cancer Research Center, Seattle, Washington 98109 (United States); Green, Damian J.; Press, Oliver W.; Pagel, John M.; Sandmaier, Brenda M. [Fred Hutchinson Cancer Research Center, Seattle, Washington 98109 and Department of Medicine, University of Washington, Seattle, Washington 98195 (United States); Hamlin, Donald K.; Wilbur, D. Scott [Department of Radiation Oncology, University of Washington, Seattle, Washington 98195 (United States); Fisher, Darrell R. [Dade Moeller Health Group, Richland, Washington 99354 (United States)

    2015-07-15

    Purpose: Alpha-emitting radionuclides exhibit a potential advantage for cancer treatments because they release large amounts of ionizing energy over a few cell diameters (50–80 μm), causing localized, irreparable double-strand DNA breaks that lead to cell death. Radioimmunotherapy (RIT) approaches using monoclonal antibodies labeled with α emitters may thus inactivate targeted cells with minimal radiation damage to surrounding tissues. Tools are needed to visualize and quantify the radioactivity distribution and absorbed doses to targeted and nontargeted cells for accurate dosimetry of all treatment regimens utilizing α particles, including RIT and others (e.g., Ra-223), especially for organs and tumors with heterogeneous radionuclide distributions. The aim of this study was to evaluate and characterize a novel single-particle digital autoradiography imager, the ionizing-radiation quantum imaging detector (iQID) camera, for use in α-RIT experiments. Methods: The iQID camera is a scintillator-based radiation detection system that images and identifies charged-particle and gamma-ray/x-ray emissions spatially and temporally on an event-by-event basis. It employs CCD-CMOS cameras and high-performance computing hardware for real-time imaging and activity quantification of tissue sections, approaching cellular resolutions. In this work, the authors evaluated its characteristics for α-particle imaging, including measurements of intrinsic detector spatial resolutions and background count rates at various detector configurations and quantification of activity distributions. The technique was assessed for quantitative imaging of astatine-211 ({sup 211}At) activity distributions in cryosections of murine and canine tissue samples. Results: The highest spatial resolution was measured at ∼20 μm full width at half maximum and the α-particle background was measured at a rate as low as (2.6 ± 0.5) × 10{sup −4} cpm/cm{sup 2} (40 mm diameter detector area

  9. Innovative procedure for the determination of gross-alpha/gross-beta activities in drinking water

    International Nuclear Information System (INIS)

    Wisser, S.; Frenzel, E.; Dittmer, M.

    2006-01-01

    An alternative sample preparation method for the determination of gross-alpha/beta activity concentrations in drinking water is introduced in this paper. After the freeze-drying of tap water samples, determination by liquid scintillation counting can be applied utilizing alpha/beta separation. It has been shown that there is no adsorption or loss of solid radionuclides during the freeze-drying procedure. However, the samples have to be measured quickly after the preparation since the ingrowth of daughter isotopes negatively effects the measurement. The limits of detection for gross-alpha and gross-beta activity are in the range 25-210 mBq/l, respectively, for a measurement time of only 8-9 h

  10. Demonstration of a laserwire emittance scanner for hydrogen ion beams at CERN

    Directory of Open Access Journals (Sweden)

    T. Hofmann

    2015-12-01

    Full Text Available A noninvasive, compact laserwire system has been developed to measure the transverse emittance of an H^{-} beam and has been demonstrated at the new LINAC4 injector for the LHC at CERN. Light from a low power, pulsed laser source is conveyed via fiber to collide with the H^{-} beam, a fraction of which is neutralized and then intercepted by a downstream diamond detector. Scanning the focused laser across the H^{-} beam and measuring the distribution of the photo-neutralized particles enables the transverse emittance to be reconstructed. The vertical phase-space distribution of a 3 MeV beam during LINAC4 commissioning has been measured by the laserwire and verified with a conventional slit and grid method.

  11. Chromospheric Ca II H and K and H-alpha emission in single and binary stars of spectral types F6-M2

    International Nuclear Information System (INIS)

    Strassmeier, K.G.; Fekel, F.C.; Bopp, B.W.; Dempsey, R.C.; Henry, G.W.

    1990-01-01

    New observations of the Ca II H and K and H-epsilon region and/or the Balmer H-alpha line are presented for 100 mostly very active stars but also for weak or inactive stars with suspected activity. Correlations between chromospheric activity at Ca II H and K and H-alpha and effective surface temperature and rotation are identified, and several new stars with chromospheric Ca II H and K emission are discovered. No single activity-rotation relation can be derived for all luminosity classes, and there is clear evidence that evolved stars are generally more active than main-sequence stars of the same rotation period. Binary within the evolved stars appears to play no role, while main-sequence binary stars show generally higher levels of activity than their single counterparts. Chromospheric emission in the Ca II H and K lines depends on surface temperature in that flux declines with cooler temperature. 63 refs

  12. A simple method for calibration of Lucas scintillation cell counting system for measurement of 226Ra and 222Rn

    Directory of Open Access Journals (Sweden)

    N.K. Sethy

    2014-10-01

    Full Text Available Known quantity of radium from high grade ore solution was chemically separated and carefully kept inside the cavity of a Lucas Cell (LC. The 222Rn gradually builds up and attain secular equilibrium with its parent 226Ra. This gives a steady count after a suitable buildup period (>25 days. This secondary source was used to calibrate the radon counting system. The method is validated in by comparison with identical measurement with AlphaGuard Aquakit. The radon counting system was used to evaluate dissolved radon in ground water sample by gross alpha counting in LC. Radon counting system measures the collected radon after a delay of >180 min by gross alpha counting. Simultaneous measurement also carried out by AlphaGuard Aquakit in identical condition. AlphaGuard measures dissolved radon from water sample by constant aeration in a closed circuit without giving any delay. Both the methods are matching with a correlation coefficient of >0.9. This validates the calibration of Lucas scintillation cell counting system by designed encapsulated source. This study provides an alternative for calibration in absence of costly Radon source available in the market.

  13. Standardization of Ga-68 by coincidence measurements, liquid scintillation counting and 4πγ counting.

    Science.gov (United States)

    Roteta, Miguel; Peyres, Virginia; Rodríguez Barquero, Leonor; García-Toraño, Eduardo; Arenillas, Pablo; Balpardo, Christian; Rodrígues, Darío; Llovera, Roberto

    2012-09-01

    The radionuclide (68)Ga is one of the few positron emitters that can be prepared in-house without the use of a cyclotron. It disintegrates to the ground state of (68)Zn partially by positron emission (89.1%) with a maximum energy of 1899.1 keV, and partially by electron capture (10.9%). This nuclide has been standardized in the frame of a cooperation project between the Radionuclide Metrology laboratories from CIEMAT (Spain) and CNEA (Argentina). Measurements involved several techniques: 4πβ-γ coincidences, integral gamma counting and Liquid Scintillation Counting using the triple to double coincidence ratio and the CIEMAT/NIST methods. Given the short half-life of the radionuclide assayed, a direct comparison between results from both laboratories was excluded and a comparison of experimental efficiencies of similar NaI detectors was used instead. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. Theoretical response of a ZnS(Ag) scintillation detector to alpha-emitting sources and suggested applications

    International Nuclear Information System (INIS)

    Skrable, K.W.; Phoenix, K.A.; Chabot, G.E.; French, C.S.; Jo, M.; Falo, G.A.

    1991-01-01

    The classic problem of alpha absorption is discussed in terms of the quantitative determination of the activity of weightless alpha sources and the specific alpha activity of extended sources accounting for absorption in the source medium and the window of a large area ZnS(Ag) scintillation detector. The relationship for the expected counting rate gamma of a monoenergetic source of active area A, specific alpha activity C, and thickness H that exceeds the effective mass density range Rs of the alpha particle in the source medium can be expressed by a quadratic equation in the window thickness x when this source is placed in direct contact with the window of the ZnS(Ag) detector. This expression also gives the expected counting rate of a finite detector of sensitive area A exposed to an infinite homogeneous source medium. Counting rates y obtained for a source separated from a ZnS(Ag) detector by different thicknesses x of window material can be used to estimate parameter values in the quadratic equation, y = a + bx + cx2. The experimental value determined for the coefficient b provides a direct estimation of the specific activity C. This coefficient, which depends on the ratio of the ranges in the source medium and detector window and not the ranges themselves, is essentially independent of the energy of the alpha particle. Although certain experimental precautions must be taken, this method for estimating the specific activity C is essentially an absolute method that does not require the use of standards, special calibrations, or complicated radiochemical procedures. Applications include the quantitative determination of Rn and progeny in air, water, and charcoal, and the measurement of the alpha activity in soil and on air filter samples

  15. Accurate estimation of the RMS emittance from single current amplifier data

    International Nuclear Information System (INIS)

    Stockli, Martin P.; Welton, R.F.; Keller, R.; Letchford, A.P.; Thomae, R.W.; Thomason, J.W.G.

    2002-01-01

    This paper presents the SCUBEEx rms emittance analysis, a self-consistent, unbiased elliptical exclusion method, which combines traditional data-reduction methods with statistical methods to obtain accurate estimates for the rms emittance. Rather than considering individual data, the method tracks the average current density outside a well-selected, variable boundary to separate the measured beam halo from the background. The average outside current density is assumed to be part of a uniform background and not part of the particle beam. Therefore the average outside current is subtracted from the data before evaluating the rms emittance within the boundary. As the boundary area is increased, the average outside current and the inside rms emittance form plateaus when all data containing part of the particle beam are inside the boundary. These plateaus mark the smallest acceptable exclusion boundary and provide unbiased estimates for the average background and the rms emittance. Small, trendless variations within the plateaus allow for determining the uncertainties of the estimates caused by variations of the measured background outside the smallest acceptable exclusion boundary. The robustness of the method is established with complementary variations of the exclusion boundary. This paper presents a detailed comparison between traditional data reduction methods and SCUBEEx by analyzing two complementary sets of emittance data obtained with a Lawrence Berkeley National Laboratory and an ISIS H - ion source

  16. Low emittance photoinjectors

    International Nuclear Information System (INIS)

    Ferrario, Massimo

    2001-01-01

    Photon colliders require high charge polarized electron beams with very low normalized emittances, possibly lower than the actual damping rings design goals. Recent analytical and numerical efforts in understanding beam dynamics in RF photoinjectors have raised again the question as to whether the performances of an RF electron gun based injector could be competitive with respect to a damping ring. As a matter of discussion we report in this paper the most recent results concerning low emittance photoinjector designs: the production of polarized electron beams by DC and/or RF guns is illustrated together with space charge compensation techniques and thermal emittance effects. New ideas concerning multi-gun injection system and generation of flat beams by RF gun are also discussed

  17. SUB-THz AND H{alpha} ACTIVITY DURING THE PREFLARE AND MAIN PHASES OF A GOES CLASS M2 EVENT

    Energy Technology Data Exchange (ETDEWEB)

    Kaufmann, Pierre; Gimenez de Castro, C. Guillermo; Raulin, Jean-Pierre; Correia, Emilia; Fernandes, Luis Olavo; De Souza, Rodney V. [CRAAM, Escola de Engenharia, Universidade Presbiteriana Mackenzie, Sao Paulo (Brazil); Marcon, Rogerio [IFGW, Universidade Estadual de Campinas (Brazil); White, Stephen M. [AFRL, Space Vehicles Directorate, Albuquerque, NM (United States); Godoy, Rodolfo; Marun, Adolfo; Pereyra, Pablo [Complejo Astronomico El Leoncito, CONICET, San Juan (Argentina)

    2011-12-01

    Radio and optical observations of the evolution of flare-associated phenomena have shown an initial and rapid burst at 0.4 THz only followed subsequently by a localized chromospheric heating producing an H{alpha} brightening with later heating of the whole active region. A major instability occurred several minutes later producing one impulsive burst at microwaves only, associated with an M2.0 GOES X-ray flare that exhibited the main H{alpha} brightening at the same site as the first flash.The possible association between long-enduring time profiles at soft X-rays, microwaves, H{alpha}, and sub-THz wavelengths is discussed. In the decay phase, the H{alpha} movie shows a disrupting magnetic arch structure ejecting dark, presumably chromospheric, material upward. The time sequence of events suggests genuine interdependent and possibly non-thermal instabilities triggering phenomena, with concurrent active region plasma heating and material ejection.

  18. A novel method for rapid in vitro radiobioassay

    Science.gov (United States)

    Crawford, Evan Bogert

    minutes of sample preparation and counting time. Radiation detector spectra -- e.g. those from high-purity germanium (HPGe) gamma detectors and liquid scintillation detectors -- which contain decay signals from multiple isotopes often have overlapping signals: the counts from one isotope's decay can appear in energy channels associated with another isotope's decay, complicating the calculation of each isotope's activity. The uncertainties associated with analyzing these spectra have been traced in order to determine the effects of one isotope's count rate on the sensitivity and uncertainty associated with each other isotope. The method that was developed takes advantage of activated carbon filtration to eliminate quenching effects and to make the liquid scintillation spectra from different urine samples comparable. The method uses pulse-shape analysis to reduce the interference from beta emitters in the liquid scintillation spectrum and improve the minimum detectable activity (MDA) and minimum quantifiable activity (MQA) for alpha emitters. The method uses an HPGe detector to quantify the activity of gamma emitters, and subtract their isotopes' contributions to the liquid scintillation spectra via a calibration factor, such that the pure beta and pure alpha emitters can be identified and quantified from the resulting liquid scintillation spectra. Finally, the method optionally uses extractive scintillators to rapidly separate the alpha emitters from the beta emitters when the activity from the beta emitters is too great to detect or quantify the activity from the alpha emitters without such a separation. The method is able to detect and quantify all five isotopes, with uncertainties and biases usually in the 10-40% range, depending upon the isotopic mixtures and the activity ratios between each of the isotopes.

  19. Fabrication of multi-emitter array of CNT for enhancement of current density

    Energy Technology Data Exchange (ETDEWEB)

    Chouhan, Vijay, E-mail: vchouhan@post.kek.jp [Department of Accelerator Science, Graduate University for Advanced Studies, 1-1 Oho, Tsukuba, Ibaraki (Japan); Noguchi, Tsuneyuki [High Energy Accelerator Research Organization-KEK, 1-1 Oho, Tsukuba, Ibaraki (Japan); Kato, Shigeki [Department of Accelerator Science, Graduate University for Advanced Studies, 1-1 Oho, Tsukuba, Ibaraki (Japan); High Energy Accelerator Research Organization-KEK, 1-1 Oho, Tsukuba, Ibaraki (Japan)

    2011-11-11

    We studied and compared field emission properties of two kinds of emitters of randomly oriented multi-wall carbon nanotubes (MWNTs), viz. continuous film emitter (CFE) and multi-emitter array (MEA). The CFE has a continuous film of MWNTs while the MEA consists of many equidistant small circular emitters. Both types of emitters were prepared by dispersing MWNTs over a titanium (Ti) film (for CFEs) or Ti circular islands (for MEAs) deposited on tantalum (Ta) followed by rooting of MWNTs into the Ti film or the Ti islands at high temperature. Emission properties of both types of emitters were analyzed with changing their emission areas. In case of the CFEs, current density decreased with an increase in emission area whereas consistent current densities were achieved from MEAs with different emission areas. In other words, the total emission current was achieved in proportion to the emission area in the case of MEAs. Additionally a high current density of 22 A/cm{sup 2} was achieved at an electric field of 8 V/{mu}m from MEAs, which was far better than that obtained from CFEs. The high current density in MEAs was attributed to edge effect, in which higher emission current is achieved from the edge of film emitter. The results indicate that the field emission characteristics can be greatly improved if a cathode contains many small equidistant circular emitters instead of a continuous film. The outstanding stability of the CFE and the MEA has been demonstrated for 2100 and 1007 h, respectively.

  20. Prediction and design of efficient exciplex emitters for high-efficiency, thermally activated delayed-fluorescence organic light-emitting diodes.

    Science.gov (United States)

    Liu, Xiao-Ke; Chen, Zhan; Zheng, Cai-Jun; Liu, Chuan-Lin; Lee, Chun-Sing; Li, Fan; Ou, Xue-Mei; Zhang, Xiao-Hong

    2015-04-08

    High-efficiency, thermally activated delayed-fluorescence organic light-emitting diodes based on exciplex emitters are demonstrated. The best device, based on a TAPC:DPTPCz emitter, shows a high external quantum efficiency of 15.4%. Strategies for predicting and designing efficient exciplex emitters are also provided. This approach allow prediction and design of efficient exciplex emitters for achieving high-efficiency organic light-emitting diodes, for future use in displays and lighting applications. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Advanced computer-controlled automatic alpha-beta air sample counter

    International Nuclear Information System (INIS)

    Howell, W.P.; Bruinekool, D.J.; Stapleton, E.E.

    1983-01-01

    An improved computer controlled automatic alpha-beta air sample counter was developed, based upon an earlier automatic air sample counter design. The system consists of an automatic sample changer, an electronic counting system utilizing a large silicon diode detector, a small desk-type microcomputer, a high speed matrix printer, and the necessary data interfaces. The system is operated by commands from the keyboard and programs stored on magnetic tape cassettes. The programs provide for background counting, Chi 2 test, radon subtraction, and sample counting for sample periods of one day to one week. Output data are printed by the matrix printer on standard multifold paper. The data output includes gross beta, gross alpha, and plutonium results. Data are automatically corrected for background, counter efficiency, and in the gross alpha and plutonium channels, for the presence of radon

  2. Management of alpha-contaminated wastes

    International Nuclear Information System (INIS)

    1980-01-01

    : 1) As regards the definition what is an alpha-bearing waste, it seemed that a number of participants were supporting the idea that such a value might be based on the concept of the MPC (maximum permissible concentration) - for drinkable water - and that the radioactivity of these wastes might be expressed in such a way in view of the conditioning and the disposal requirements. 2) It was the consensus that it is necessary to prevent production of large amounts of alpha-bearing wastes by improving the engineering and operational procedures of the reprocessing units and of the fuel fabrication plants, and to recover the major part of alpha emitters (plutonium) from the wastes by recycling. 3) As far as the treatment of such wastes is concerned, methods for reducing the volume have been improved. Techniques for sectioning large items and decontamination processes are now available Incineration at low temperature has proved its efficiency for the volume reduction Slagging incineration and acid digestion are also ready for an industrial development. 4) With regard to the conditioning it appeared that, in addition to the borosilicate glasses which are developed to industrial scale in France, several other matrices are under consideration and the first results are very promising. These matrices include vitreous and crystalline ceramics and synthetic rock materials. A substantial effort has been done in this field to ensure the quality of the final waste form for disposal. 5) For the monitoring of alpha emitters in the waste, several techniques are applicable at industrial level; they include gamma spectrography and passive neutron counting. Active neutron assay is under improvement and the results are very promising. A new technique is also under consideration using linear accelerator technology to detect trace amounts of transuranics in waste barrels. 6) As regards the actinide partitioning from high-level waste, great progress was made at laboratory scale using different

  3. Detectors for alpha particles and X-rays operating in ambient air in pulse counting mode or/and with gas amplification

    International Nuclear Information System (INIS)

    Charpak, G; Benaben, P; Breuil, P; Peskov, V

    2008-01-01

    Ionization chambers working in ambient air in current detection mode are attractive due to their simplicity and low cost and are widely used in several applications such as smoke detection, dosimetry, therapeutic beam monitoring and so on. The aim of this work was to investigate if gaseous detectors can operate in ambient air in pulse counting mode as well as with gas amplification which potentially offers the highest possible sensitivity in applications like alpha particle detection or high energy X-ray photon or electron detection. To investigate the feasibility of this method two types of open- end gaseous detectors were build and successfully tested. The first one was a single wire or multiwire cylindrical geometry detector operating in pulse mode at a gas gain of one (pulse ionization chamber). This detector was readout by a custom made wide -band charge sensitive amplifier able to deal with slow induced signals generated by slow motion of negative and positive ions. The multiwire detector was able to detect alpha particles with an efficiency close to 22%. The second type of an alpha detector was an innovative GEM-like detector with resistive electrodes operating in air in avalanche mode at high gas gains (up to 10 4 ). This detector can also operate in a cascaded mode or being combined with other detectors, for example with MICROMEGAS. This detector was readout by a conventional charge -sensitive amplifier and was able to detect alpha particles with 100% efficiency. This detector could also detect X-ray photons or fast electrons. A detailed comparison between these two detectors is given as well as a comparison with commercially available alpha detectors. The main advantages of gaseous detectors operating in air in a pulse detection mode are their simplicity, low cost and high sensitivity. One of the possible applications of these new detectors is alpha particle background monitors which, due to their low cost can find wide application not only in houses, but

  4. THE LYMAN ALPHA REFERENCE SAMPLE: EXTENDED LYMAN ALPHA HALOS PRODUCED AT LOW DUST CONTENT

    Energy Technology Data Exchange (ETDEWEB)

    Hayes, Matthew [Universite de Toulouse, UPS-OMP, IRAP, Toulouse (France); Oestlin, Goeran; Duval, Florent; Guaita, Lucia; Melinder, Jens; Sandberg, Andreas [Department of Astronomy, Oskar Klein Centre, Stockholm University, AlbaNova University Centre, SE-106 91 Stockholm (Sweden); Schaerer, Daniel [CNRS, IRAP, 14, avenue Edouard Belin, F-31400 Toulouse (France); Verhamme, Anne; Orlitova, Ivana [Geneva Observatory, University of Geneva, 51 Chemin des Maillettes, CH-1290 Versoix (Switzerland); Mas-Hesse, J. Miguel; Oti-Floranes, Hector [Centro de Astrobiologia (CSIC-INTA), Departamento de Astrofisica, POB 78, 28691 Villanueva de la Canada (Spain); Adamo, Angela [Max Planck Institute for Astronomy, Koenigstuhl 17, D-69117 Heidelberg (Germany); Atek, Hakim [Laboratoire d' Astrophysique, Ecole Polytechnique Federale de Lausanne (EPFL), Observatoire, CH-1290 Sauverny (Switzerland); Cannon, John M. [Department of Physics and Astronomy, Macalester College, 1600 Grand Avenue, Saint Paul, MN 55105 (United States); Herenz, E. Christian [Leibniz-Institut fuer Astrophysik (AIP), An der Sternwarte 16, D-14482 Potsdam (Germany); Kunth, Daniel [Institut d' Astrophysique de Paris, UMR 7095 CNRS and UPMC, 98 bis Bd Arago, F-75014 Paris (France); Laursen, Peter, E-mail: matthew@astro.su.se [Dark Cosmology Centre, Niels Bohr Institute, University of Copenhagen, Juliane Maries Vej 30, DK-2100 Copenhagen (Denmark)

    2013-03-10

    We report on new imaging observations of the Lyman alpha emission line (Ly{alpha}), performed with the Hubble Space Telescope, that comprise the backbone of the Lyman alpha Reference Sample. We present images of 14 starburst galaxies at redshifts 0.028 < z < 0.18 in continuum-subtracted Ly{alpha}, H{alpha}, and the far ultraviolet continuum. We show that Ly{alpha} is emitted on scales that systematically exceed those of the massive stellar population and recombination nebulae: as measured by the Petrosian 20% radius, R{sub P20}, Ly{alpha} radii are larger than those of H{alpha} by factors ranging from 1 to 3.6, with an average of 2.4. The average ratio of Ly{alpha}-to-FUV radii is 2.9. This suggests that much of the Ly{alpha} light is pushed to large radii by resonance scattering. Defining the Relative Petrosian Extension of Ly{alpha} compared to H{alpha}, {xi}{sub Ly{alpha}} = R {sup Ly{alpha}}{sub P20}/R {sup H{alpha}}{sub P20}, we find {xi}{sub Ly{alpha}} to be uncorrelated with total Ly{alpha} luminosity. However, {xi}{sub Ly{alpha}} is strongly correlated with quantities that scale with dust content, in the sense that a low dust abundance is a necessary requirement (although not the only one) in order to spread Ly{alpha} photons throughout the interstellar medium and drive a large extended Ly{alpha} halo.

  5. The determination of plutonium alpha activity in urine, faeces and biological materials

    International Nuclear Information System (INIS)

    Bains, M.E.D.

    1963-07-01

    Methods have been developed for the determination of plutonium alpha activity in urine, faeces and biological materials. The chemical stages involved give practically complete separation of all extraneous material from the plutonium, which is electrodeposited on to a 0.5 inch stainless steel disc to produce a thin high resolution source. The limit of detection is 0.025 μμc/sample (sixteen-hour count) when the sources are counted in a small scintillator counter, but is lowest when counted in a counter which counts particles of energy 5.05-5.25 MeV only, and which therefore discriminates against small quantities of α-active materials introduced with the reagents in the final electrodeposition stage of the process. (Any such alpha activity may readily be identified by alpha pulse height analysis). (author)

  6. Characterisation of the binding of [{sup 3}H]methyllycaconitine: a new radioligand for labelling {alpha}7-type neuronal nicotinic acetylcholine receptors

    Energy Technology Data Exchange (ETDEWEB)

    Davies, A.R.L.; Wolstenholme, A.J.; Wonnacott, S. [Department of Biology and Biochemistry, University of Bath, Bath BA2 7AY (United Kingdom); Hardick, D.J.; Blagbrough, I.S.; Potter, B.V.L. [Department of Pharmacy and Pharmacology, University of Bath, Bath BA2 7AY (United Kingdom)

    1999-05-15

    Methyllycaconitine (MLA), a norditerpenoid alkaloid isolated from Delphinium seeds, is one of the most potent non-proteinacious ligands that is selective for {alpha}bungarotoxin-sensitive neuronal nicotinic acetylcholine receptors (nAChR). [{sup 3}H]MLA bound to rat brain membranes with high affinity (K{sub d}=1.86{+-}0.31 nM) with a good ratio of specific to non-specific binding. The binding of [{sup 3}H]MLA was characterised by rapid association (t{sub 1/2}=2.3 min) and dissociation (t{sub 1/2}=12.6 min) kinetics. The radioligand binding displayed nicotinic pharmacology, consistent with an interaction with {alpha}bungarotoxin-sensitive nAChR. The snake {alpha}-toxins, {alpha}bungarotoxin and {alpha}cobratoxin, displaced [{sup 3}H]MLA with high affinity (K{sub i}=1.8{+-}0.5 and 5.5{+-}0.9 nM, respectively), whereas nicotine was less potent (K{sub i}=6.1{+-}1.1 {mu}M). The distribution of [{sup 3}H]MLA binding sites in crudely dissected rat brain regions was identical to that of [{sup 125}I]{alpha}bungarotoxin binding sites, with a high binding site density in hippocampus and hypothalamus, but low density in striatum and cerebellum. [{sup 3}H]MLA also labelled a sub-population of binding sites which are not sensitive to the snake {alpha}toxins, but which did not differ significantly from the major population with respect to their other pharmacological properties or regional distribution. [{sup 3}H]MLA, therefore, is a novel radiolabel for characterising {alpha}7-type nAChR. A good signal to noise ratio and rapid binding kinetics provide advantages over the use of radiolabelled {alpha}bungarotoxin for rapid and accurate equilibrium binding assays. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

  7. Therapeutic Efficacy of Alpha-RIT Using a (213)Bi-Anti-hCD138 Antibody in a Mouse Model of Ovarian Peritoneal Carcinomatosis.

    Science.gov (United States)

    Derrien, Aurélie; Gouard, Sébastien; Maurel, Catherine; Gaugler, Marie-Hélène; Bruchertseifer, Frank; Morgenstern, Alfred; Faivre-Chauvet, Alain; Classe, Jean-Marc; Chérel, Michel

    2015-01-01

    Ovarian peritoneal carcinomatosis is a pathology for which effective cures are currently lacking. New research protocols seek to eradicate residual micrometastases following cytoreductive surgery by using hyperthermic intraperitoneal chemotherapy (HIPEC) or radioimmunotherapy (RIT). This study aims to first develop alpha-RIT using an anti-CD138 mAb radiolabeled with an alpha-emitter, bismuth-213 ((213)Bi-B-B4) and HIPEC in a nude mouse model and second to compare and combine these techniques. A murine model of postoperative ovarian peritoneal carcinomatosis was established. A pilot group of six mice received an intraperitoneal injection of luciferase-tagged SHIN-3 cells and bioluminescence was measured every day. Cytoreductive surgery was performed at day 14 (n = 4) and 29 (n = 2). Because the residual bioluminescence signal measured after surgery was equivalent to that obtained 3 days after the graft, HIPEC or alpha-RIT treatments were applied 3 days after the graft. Ten mice were treated by HIPEC with cisplatine (37.5 mg/mL), 11 with 7.4 MBq of (213)Bi-B-B4, seven with 11.1 MBq of (213)Bi-B-B4, and 10 mice were treated with the combined therapy (HIPEC + 7.4 MBq of (213)Bi-B-B4). Eleven mice received no treatment. Bioluminescence imaging and survival were assessed. Alpha-RIT 7.4 MBq and 11.1 MBq significantly improved survival (p = 0.0303 and p = 0.0070, respectively), whereas HIPEC and HIPEC + alpha-RIT treatments did not significantly ameliorate survival as compared to the control group. Survival was significantly increased by alpha-RIT treatment in mice with peritoneal carcinomatosis of ovarian origin; however, HIPEC alone or in combination with alpha-RIT had no significant effect.

  8. Alpha-beta-gamma spectrometer as an aid in directing decontamination of soils

    International Nuclear Information System (INIS)

    Berger, C.D.

    1981-01-01

    This technique permits rapid assessment of alpha-beta-gamma-emitter contamination in soils at sufficiently low concentrations to direct field operations. Of particular importance is its applicability during initial decommissioning and decontamination surveys when characterization of alpha and beta contamination in the presence of a high gamma background is necessary. This system has not yet been made portable for in-situ use, but it is expected that results willbe favorable when operated as a field instrument, resulting in simplified standard decontamination operation

  9. High brightness fiber laser pump sources based on single emitters and multiple single emitters

    Science.gov (United States)

    Scheller, Torsten; Wagner, Lars; Wolf, Jürgen; Bonati, Guido; Dörfel, Falk; Gabler, Thomas

    2008-02-01

    Driven by the potential of the fiber laser market, the development of high brightness pump sources has been pushed during the last years. The main approaches to reach the targets of this market had been the direct coupling of single emitters (SE) on the one hand and the beam shaping of bars and stacks on the other hand, which often causes higher cost per watt. Meanwhile the power of single emitters with 100μm emitter size for direct coupling increased dramatically, which also pushed a new generation of wide stripe emitters or multi emitters (ME) of up to 1000μm emitter size respectively "minibars" with apertures of 3 to 5mm. The advantage of this emitter type compared to traditional bars is it's scalability to power levels of 40W to 60W combined with a small aperture which gives advantages when coupling into a fiber. We show concepts using this multiple single emitters for fiber coupled systems of 25W up to 40W out of a 100μm fiber NA 0.22 with a reasonable optical efficiency. Taking into account a further efficiency optimization and an increase in power of these devices in the near future, the EUR/W ratio pushed by the fiber laser manufacturer will further decrease. Results will be shown as well for higher power pump sources. Additional state of the art tapered fiber bundles for photonic crystal fibers are used to combine 7 (19) pump sources to output powers of 100W (370W) out of a 130μm (250μm) fiber NA 0.6 with nominal 20W per port. Improving those TFB's in the near future and utilizing 40W per pump leg, an output power of even 750W out of 250μm fiber NA 0.6 will be possible. Combined Counter- and Co-Propagated pumping of the fiber will then lead to the first 1kW fiber laser oscillator.

  10. Investigation of Performance Silicon Heterojunction Solar Cells Using a-Si: H or a-SiC: H at Emitter Layer Through AMPS-1D Simulations

    Directory of Open Access Journals (Sweden)

    Asmaa BENSMAIN

    2014-05-01

    Full Text Available We offer a numerical simulation tool, AMPS-1D, which allows to model homo- as well as heterojunction devices. AMPS-1D is the short form of automat for simulation of heterostructures. The program solves the one dimensional semiconductor equations in steady-state. Furthermore, a variety of common characterization techniques have been implemented, current- voltage, external quantum efficiency, conduction and valence band. A user-friendly interface allows to easily perform parameter variations, and to visualize and compare your simulations. In this work, The silicon heterojunction cell performances are investigated by detailed described on external quantum efficiency, and light current-voltage characteristics by recognized simulator AMPS-1D (Analysis of Micro- electronics and Photonic Structures. The objective of this work is to study the correlation between the emitter properties of both heterojunction cells a-Si:H/c-Si and a-SiC:H/c-Si (absorption, defect profiles and energy band offsets and the carrier collection.

  11. Full-disk Solar H-alpha Images From GONG

    Science.gov (United States)

    Harvey, J. W.; Bolding, J.; Clark, R.; Hauth, D.; Hill, F.; Kroll, R.; Luis, G.; Mills, N.; Purdy, T.; Henney, C.; Holland, D.; Winter, J.

    2011-05-01

    Since mid-2010 the Global Oscillation Network Group (GONG) has collected H-alpha images at six sites around the world. These images provide a near real-time solar activity patrol for use in space weather applications and also an archive for research purposes. Images are collected once per minute, dark, smear, and flat corrected, compressed and then sent via the Internet to a 'cloud' server where reduction is completed. Various reduced images are usually available within a minute after exposure. The H-alpha system is an add-on to the normal GONG helioseismology instrument and does not interfere with regular observations. A polarizing beamsplitter sends otherwise unused 656 nm light through two lenses to a Daystar 0.04 nm mica etalon filter. The filter is matched to an image of the GONG light feed entrance pupil and sees an image of the Sun at infinity. Two lenses behind the filter form the solar image on a DVC-4000 2k x 2k interline transfer CCD camera. Exposure times are automatically adjusted to maintain the quiet disk center at 20% of full dynamic range to avoid saturation by bright flares. Image resolution is limited by diffraction, seeing and some high-order wavefront errors in the filters. A unique dual-heater system was developed by Daystar to homogenize the passband characteristics of the mica etalons. The data are in regular use for space weather forecasting by the U.S. Air Force Weather Agency, which funded construction and installation of the instruments. Operational and reduction improvements are underway and archived data are already being used for research projects. The Web site URL is http://halpha.nso.edu.

  12. Low emittance electron storage rings

    Science.gov (United States)

    Levichev, E. B.

    2018-01-01

    Low-emittance electron (positron) beams are essential for synchrotron light sources, linear collider damping rings, and circular Crab Waist colliders. In this review, the principles and methods of emittance minimization are discussed, prospects for developing relativistic electron storage rings with small beam phase volume are assessed, and problems related to emittance minimization are examined together with their possible solutions. The special features and engineering implementation aspects of various facilities are briefly reviewed.

  13. Improving Defect-Based Quantum Emitters in Silicon Carbide via Inorganic Passivation.

    Science.gov (United States)

    Polking, Mark J; Dibos, Alan M; de Leon, Nathalie P; Park, Hongkun

    2018-01-01

    Defect-based color centers in wide-bandgap crystalline solids are actively being explored for quantum information science, sensing, and imaging. Unfortunately, the luminescent properties of these emitters are frequently degraded by blinking and photobleaching that arise from poorly passivated host crystal surfaces. Here, a new method for stabilizing the photoluminescence and charge state of color centers based on epitaxial growth of an inorganic passivation layer is presented. Specifically, carbon antisite-vacancy pairs (CAV centers) in 4H-SiC, which serve as single-photon emitters at visible wavelengths, are used as a model system to demonstrate the power of this inorganic passivation scheme. Analysis of CAV centers with scanning confocal microscopy indicates a dramatic improvement in photostability and an enhancement in emission after growth of an epitaxial AlN passivation layer. Permanent, spatially selective control of the defect charge state can also be achieved by exploiting the mismatch in spontaneous polarization at the AlN/SiC interface. These results demonstrate that epitaxial inorganic passivation of defect-based quantum emitters provides a new method for enhancing photostability, emission, and charge state stability of these color centers. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. High-precision half-life measurements for the superallowed Fermi β+ emitter 14O

    Science.gov (United States)

    Laffoley, A. T.; Svensson, C. E.; Andreoiu, C.; Austin, R. A. E.; Ball, G. C.; Blank, B.; Bouzomita, H.; Cross, D. S.; Diaz Varela, A.; Dunlop, R.; Finlay, P.; Garnsworthy, A. B.; Garrett, P. E.; Giovinazzo, J.; Grinyer, G. F.; Hackman, G.; Hadinia, B.; Jamieson, D. S.; Ketelhut, S.; Leach, K. G.; Leslie, J. R.; Tardiff, E.; Thomas, J. C.; Unsworth, C.

    2013-07-01

    The half-life of the superallowed Fermi β+ emitter 14O has been determined via simultaneous direct β and γ counting experiments at TRIUMF's Isotope Separator and Accelerator (ISAC) facility. A γ-ray counting measurement was performed by detecting the 2312.6-keV γ rays emitted from an excited state of the daughter 14N following the implantation of samples at the center of the 8π γ-ray spectrometer, a spherical array of 20 high-purity germanium (HPGe) detectors. A simultaneous β counting experiment was performed using a fast plastic scintillator positioned behind the implantation site with a solid angle coverage of ˜20%. The results, T1/2(β)=70.610±0.030s and T1/2(γ)=70.632±0.094s, form a consistent set and, together with eight previous measurements, establish a new average for the 14O half-life of T1/2=70.619±0.011s with a reduced χ2 of 0.99.

  15. Sources of series resistance in the Harwell solid state alpha detector

    International Nuclear Information System (INIS)

    Rawlings, K.J.

    1985-12-01

    The metal-semiconductor contacts to the Harwell solid state alpha detector have been characterized and the effect of the contact geometry has been assessed. To a reasonable approximation the latter gives rise to an emitter series resistance with an expected range of 20 +- 8 ohms. The contacts behave like parallel RC networks which become noticeably frequency dependent above ca. 100 kHz. Up to this frequency the emitter contact is likely to add 6 +- 4 ohms to the series resistance and the contribution from the base contact varies inversely with the square of the diode's diameter, being 5 +- 3 ohms for a diode with a diameter of 30 mm. (author)

  16. AMPK alpha1 activation is required for stimulation of glucose uptake by twitch contraction, but not by H2O2, in mouse skeletal muscle

    DEFF Research Database (Denmark)

    Jensen, Thomas Elbenhardt; Schjerling, Peter; Viollet, Benoit

    2008-01-01

    into muscle by certain stimuli. In contrast, no clear function has yet been determined for alpha(1) AMPK in skeletal muscle, possibly due to alpha-AMPK isoform signaling redundancy. By applying low-intensity twitch-contraction and H(2)O(2) stimulation to activate alpha(1) AMPK, but not alpha(2) AMPK......, in wildtype and alpha-AMPK transgenic mouse muscles, this study aimed to define conditions where alpha(1) AMPK is required to increase muscle glucose uptake. METHODOLOGY/PRINCIPAL FINDINGS: Following stimulation with H(2)O(2) (3 mM, 20 min) or twitch-contraction (0.1 ms pulse, 2 Hz, 2 min), signaling and 2......-deoxyglucose uptake were measured in incubated soleus muscles from wildtype and muscle-specific kinase-dead AMPK (KD), alpha(1) AMPK knockout or alpha(2) AMPK knockout mice. H(2)O(2) increased the activity of both alpha(1) and alpha(2) AMPK in addition to Akt phosphorylation, and H(2)O(2)-stimulated glucose...

  17. Investigation of alpha emitters in fresh and powdered blood of fertile women: an in vitro application of CR-39 NTDs

    International Nuclear Information System (INIS)

    Salih, N.F.; University of Koya, Kurdistan; Jaafar, M.S.

    2014-01-01

    Blood samples were acquired from 60 women aged 20-44 years having decreased fertility, infertile or with uterine tumors in the Iraqi Kurdistan region. The concentrations of α emitters in fresh blood ranged from 0.0029 to 0.0088 ppm, whereas those in powdered blood ranged from 0.0036 ppm in Eiskan to 0.0096 ppm in Halabjay-Kon in Sulaymania. The α emitter concentrations in fresh blood ranged from 0.0029 to 0.0139 ppm, whereas those in powdered blood ranged from 0.0031 ppm in Shorsh to 0.0146 ppm in Sedakan in the Erbil Governorate. However, the concentrations of α emitters in the blood of women with decreased fertility were higher in the North than women from South Iraq. The difference significantly p < 0.001 revealed higher means of track density of fresh and powder blood in Erbil compared to Sulaymania. α are more damaging to the living tissue and exposure of the gonads leads to decreased fertility in women, most of data have been significant therefore, the result shown the radiation effect on women fertility. (author)

  18. Detectors for alpha particles and X-rays operating in ambient air in pulse counting mode and/or with gas amplification

    CERN Document Server

    Charpak, Georges; Breuil, P; Peskov, Vladimir

    2008-01-01

    Ionization chambers working in ambient air in current detection mode are widely used in several applications such as smoke detection, dosimetry, therapeutic beam monitoring and cetera. The aim of this work was to investigate if gaseous detectors can operate in ambient air in pulse counting mode as well as with gas amplification. . To investigate the feasibility of this method two types of open- end gaseous detectors were build and successfully tested. The first one was a single wire or multiwire cylindrical geometry detector operating in pulse mode at a gas gain of 1. The second type alpha detector was an innovative GEM-like detector with resistive electrodes operating in air in avalanche mode at high gas gains (up to 10E4). A detailed comparison between these two detectors is given as well as comparison with the commercially available alpha detectors. The main advantages of gaseous detectors operating in air in a pulse detection mode are their simplicity, low cost and high sensitivity. One of the possible ap...

  19. Rapid measurement of 3J(H N-H alpha) and 3J(N-H beta) coupling constants in polypeptides.

    Science.gov (United States)

    Barnwal, Ravi Pratap; Rout, Ashok K; Chary, Kandala V R; Atreya, Hanudatta S

    2007-12-01

    We present two NMR experiments, (3,2)D HNHA and (3,2)D HNHB, for rapid and accurate measurement of 3J(H N-H alpha) and 3J(N-H beta) coupling constants in polypeptides based on the principle of G-matrix Fourier transform NMR spectroscopy and quantitative J-correlation. These experiments, which facilitate fast acquisition of three-dimensional data with high spectral/digital resolution and chemical shift dispersion, will provide renewed opportunities to utilize them for sequence specific resonance assignments, estimation/characterization of secondary structure with/without prior knowledge of resonance assignments, stereospecific assignment of prochiral groups and 3D structure determination, refinement and validation. Taken together, these experiments have a wide range of applications from structural genomics projects to studying structure and folding in polypeptides.

  20. Determination of Uranium plus Plutonium by Alpha spectrometry in different matrix

    International Nuclear Information System (INIS)

    Equillor, Hugo E.; Campos, Juan M.

    2011-01-01

    Usually, the determination of alpha emitters by alpha spectrometry is performed with a prior purification of each of the elements to be quantified. In this work, a methodology for the determination of uranium and plutonium isotopes as jointly described, in order to improve analytical processing times and measurement. The method includes purifying uranium and plutonium, and the subsequent electrodeposition for alpha spectrometry measurement. The technique is based on the use of TBP (tributyl phosphate) as extractant and easy to obtain reactants. It is applicable to various matrices, including water, filters and soils. In the conditions described, is applied to small aliquots of approximately 0.5 g of solid. The technique produces high quality electrodeposits. (authors) [es

  1. Reduced widths of alpha -decay of near-magic even-even nuclei

    CERN Document Server

    Kar Yan, N

    1972-01-01

    Precision on-line investigations on the linear heavy-ion Berkeley accelerator, and on the CERN synchrophasotron were carried out recently on new alpha -emitters. The results obtained are analysed with a view to finding the degree of correspondence, or disagreement, with the authors' own ideas about alpha -decay processes. The discussion is confined to examining even isotopes of polonium, radon, radium and thorium Several theoretical and experimental plots are given of reduced widths of alpha -disintegration for different regions of shell filling and a comparison is made between barrier penetration coefficients, obtained by rigorous methods and with the aid of WKB- approximation, for /sup 212/Po, /sup 208/Po and /sup 212/Po isotopes. (24 refs).

  2. Modified theoretical minimum emittance lattice for an electron storage ring with extreme-low emittance

    Directory of Open Access Journals (Sweden)

    Yi Jiao

    2011-05-01

    Full Text Available In the continuing efforts to reduce the beam emittance of an electron storage ring composed of theoretical minimum emittance (TME lattice, down to a level of several tens of picometers, nonlinear dynamics grows to be a great challenge to the performance of the storage ring because of the strong sextupoles needed to compensate for its large global natural chomaticities coupled with its small average dispersion function. To help in dealing with the challenge of nonlinear optimization, we propose a novel variation of theoretical minimum emittance (TME lattice, named as “modified-TME” lattice, with minimal emittance about 3 times of the exact theoretical minimum, while with more compact layout, lower phase advance per cell, smaller natural chromaticities, and more relaxed optical functions than that in a TME cell, by using horizontally defocusing quadrupole closer to the dipole or simply combined-function dipole with horizontally defocusing gradient. We present approximate scaling formulas to describe the relationships of the design parameters in a modified-TME cell. The applications of modified-TME lattice in the PEP-X storage ring design are illustrated and the proposed lattice appears a good candidate for synchrotron radiation light source with extremely low emittance.

  3. Grade Assignment by Ki-67 Proliferative Index, Mitotic Count, and Phosphohistone H3 Count in Surgically Resected Gastrointestinal and Pancreatic Neuroendocrine Tumors.

    Science.gov (United States)

    Murphy, Claire E; McCormick, Kinsey A; Shankaran, Veena; Reddi, Deepti M; Swanson, Paul E; Upton, Melissa P; Papanicolau-Sengos, Antonios; Khor, Sara; Westerhoff, Maria

    The aim of this study was to evaluate the concordance in grade assignment for gastroenteropancreatic neuroendocrine tumors using mitotic count (MC), Ki-67 proliferative index (KPI), and phosphohistone H3 count (PHH3C). Resected gastroenteropancreatic neuroendocrine tumors were graded based on MC, KPI, and PHH3C. Concordance was determined using a weighted κ statistic. Median survival across each grade category was determined using Kaplan-Meier methods. Of the 110 patients, the majority had gastrointestinal primaries and grade 1 or 2 tumors. Rates of discordance in grade assignment were 29% of cases for KPI versus MC (κW = 0.26), 32% for PHH3C versus MC (κW = 0.34), and 32% for PHH3C versus KPI (κW = 0.37). There was fair agreement between grading by KPI and MC. Relative to grade by KPI and MC, PHH3C tended to upgrade tumors. The proportion alive at 3 and 5 years was not significantly different for patients with grade 1 versus grade 2 tumors. The concordance between KPI and MC was fair. Phosphohistone H3 count tended to upgrade tumors using the cutoffs established by MC. Grade 1 and grade 2 tumors were associated with similar survival regardless of grading method. The overall relevance of the current cutoff values used in grading neuroendocrine tumors may need to be revisited.

  4. The effect of pomegranate mouthrinse on Streptococcus mutans count and salivary pH: An in vivo study.

    Science.gov (United States)

    Umar, Dilshad; Dilshad, Bahija; Farhan, Mohammed; Ali, Arshiya; Baroudi, Kusai

    2016-01-01

    Herbal mouthwashes have been considered to be a more advantageous option to their chemical counterparts, for a long-time. The use of pomegranate fruit dates from ancient times and reports of its therapeutic abilities have echoed throughout the ages. To evaluate the effect on the salivary pH and the Streptococcus mutans count in healthy subjects before and after pomegranate mouthrinse. Fifty healthy patients were randomly divided into two groups of 25 subjects each. Group A was treated with 0.2% chlorhexidine mouthrinse; while Group B was treated with pomegranate peel extract (PPE) mouthrinse and the saliva samples were collected at three different intervals: Prerinse, after 10 min, and 60 min. The salivary pH was measured using a digital pH meter and the S. mutans count was determined by the commercial system Dentocult SM. The statistical analyses used in this study are Mann-Whitney U-test and t-test. PPE mouthrinse had an inhibitory effect on S. mutans count in adults. There was also an increase in the salivary pH after 10 min of the mouthrinse. PPE mouthrinse may be considered as a potential anticariogenic mouthrinse.

  5. A device for electron gun emittance measurement

    International Nuclear Information System (INIS)

    Aune, B.; Corveller, P.; Jablonka, M.; Joly, J.M.

    1985-05-01

    In order to improve the final emittance of the beam delivered by the ALS electron linac a new gun is going to be installed. To measure its emittance and evaluate the contribution of different factors to emittance growth we have developed an emittance measurement device. We describe the experimental and mathematical procedure we have followed, and give some results of measurements

  6. An advanced computer-controlled automatic alpha-beta air sample counter

    International Nuclear Information System (INIS)

    Howell, W.P.; Bruinekool, D.J.; Stapleton, E.E.

    1984-01-01

    An improved computer-controlled automatic alpha-beta air sample counter was developed, based upon an earlier automatic air sample counter design. The system consists of an automatic sample changer, an electronic counting system utilizing a large silicon diode detector, a small desk-type microcomputer, a high-speed matrix printer and the necessary data interfaces. The system is operated by commands from the keyboard and programs stored on magnetic tape cassettes. The programs provide for background counting, Chi 2 test, radon subtraction and sample counting for sample periods of one day to one week. Output data are printed by the matrix printer on standard multifold paper. The data output includes gross beta, gross alpha and plutonium results. Data are automatically corrected for background, counter efficiency, and in the gross alpha and plutonium channels, for the presence of radon

  7. Verification of a simple method to achieve alpha/beta separation in LSC for the case of urine samples

    International Nuclear Information System (INIS)

    Oestergren, Inger; Norrlid, Lilian; Wallberg, Lena

    2008-01-01

    Full text: As a part of the national Swedish network of laboratories in emergency response and preparedness, the radio-analytical laboratory of the Swedish Radiation Protection Authority (SSI) should provide with fast and reliable measurements. To this purpose, Liquid Scintillation Counting (LSC) offers the advantages of reduced time for sample preparation, zero sample self-absorption, simultaneously measurement of alpha and beta emitters and high efficiency. The LSC detection system at SSI is a Quantulus 1220, which is a system permitting pulses produced by alpha and beta radiation to be discriminated when adjusting the software parameter Pulse Shape Analysis (PSA). Previously, different authors have found that the dependency of the optimum PSA on scintillation/vial combination is negligible in front of the strong influence of the sample quenching. Also the optimum PSA parameter is found according to each sample quench level, so as the composition of a standard and a real sample should be as close as possible. When handling samples of variable quenching levels, like for example urine, two possibilities have been suggested: 1) To determine the degree of quench in a short count of the samples and then use individual optimum PSA for each sample counting protocol; or 2) To have alpha and beta standards equivalent in quenching to the least quenched sample, determine PSA and quench the standards progressively. Then the percent of total interference is obtained as a function of the quench parameter for a single PSA setting, which permits the samples to be counted with the same protocol and a correction for interference can be applied afterwards. The case of urine is interesting since it is 95 % water but it may contain traces of amino acids and varying amounts of electrolytes, depending upon dietary intake. In this paper we applied number 2. The standards have been quenched to simulate human urine quench levels. The aim is to obtain the look-up table for the percent of

  8. Alpha particles induce expression of immunogenic markers on tumour cells

    International Nuclear Information System (INIS)

    Gorin, J.B.; Gouard, S.; Cherel, M.; Davodeau, F.; Gaschet, J.; Morgenstern, A.; Bruchertseifer, F.

    2013-01-01

    The full text of the publication follows. Radioimmunotherapy (RIT) is an approach aiming at targeting the radioelements to tumours, usually through the use of antibodies specific for tumour antigens. The radiations emitted by the radioelements then induce direct killing of the targeted cells as well as indirect killing through bystander effect. Interestingly, it has been shown that ionizing radiations, in some settings of external radiotherapy, can foster an immune response directed against tumour cells. Our research team is dedicated to the development of alpha RIT, i.e RIT using alpha particle emitters, we therefore decided to study the effects of such particles on tumour cells in regards to their immunogenicity. First, we studied the effects of bismuth 213, an alpha emitter, on cellular death and autophagy in six different tumour cell lines. Then, we measured the expression of 'danger' signals and MHC molecules at the cell surface to determine whether irradiation with 213 Bi could cause the tumour cells to be recognized by the immune system. Finally a co-culture of dendritic cells with irradiated tumour cells was performed to test whether it would induce dendritic cells to mature. No apoptosis was detected within 48 hours after irradiation in any cell line, however half of them exhibited signs of autophagy. No increase in membrane expression of 'danger' signals was observed after treatment with 213 Bi, but we showed an increase in expression of MHC class I and II for some cell lines. Moreover, the co-culture experiment indicated that the immunogenicity of a human adenocarcinoma cell line (LS 174T) was enhanced in vitro after irradiation with alpha rays. These preliminary data suggest that alpha particles could be of interest in raising an immune response associated to RIT. (authors)

  9. Longitudinal emittance blow-up and production of future LHC beams

    CERN Document Server

    Albright, S; Shaposhnikova, E

    2017-01-01

    During Long Shutdown 2 the RF systems of the PSB willbe replaced with broadband Finemet systems, there will alsobe an energy increase and many other modifications. Thisnote summarises studies that were done to investigate how tomeet the emittance requirements for the LIU-PSB baselineand a possible use of the broadband cavities to improve thecapture process.The LIU-PSB baseline requires longitudinal emittanceblow-up to 3 eVs with 205 ns bunch length at extraction. Thecurrent ferrite RF systems were used, with phase modulationof a high harmonic, to produce 2.8 eVs bunches with 220ns bunch length, as this is the largest that can currentlybe transferred to the PS. Larger emittances were possible,demonstrating the ability to reach the LIU-PSB baseline inthe future, which is confirmed in simulation.The broadband impedance of the Finemet was exploitedto allow RF voltage to be supplied on three harmonics (h=1,h=2, h=3), as opposed to the usual 2. For high intensitybeams this lead to an improved capture efficiency for...

  10. Bindings of 3H-prazosin and 3H-yohimbine to alpha adrenoceptors in the guinea-pig stomach

    International Nuclear Information System (INIS)

    Taniguchi, T.; Nishikawa, H.

    1988-01-01

    Alpha adrenoceptor subtypes have been investigated by radioligand binding study in guinea-pig stomach using 3 H-prazosin and 3 H-yohimbine. The specific 3 H-prazosin binding to guinea-pig stomach was saturable and of high affinity with a Bmax of 33 fmol/mg protein. Specific 3 H-yohimbine binding to the tissue was also saturable and of high affinity with a Bmax of 150 fmol/mg protein. Adrenergic drugs competed for 3 H-prazosin binding in order of prazosin > phentolamine > methoxamine > norepinephrine > clonidine > epinephrine > yohimbine. These drugs competed for 3 H-yohimbine binding in order of yohimbine > phentolamine > clonidine > epinephrine > norepinephrine > prazosin > methoxamine. They also examined whether dopamine receptors exist in guinea-pig stomach, using radioligand binding study. Specific binding of 3 H-spiperone, 3 H-apomorphine, 3 H-dopamine and 3 H-domperidone was not detectable in the stomach. Dopaminergic drugs such as dopamine, haloperidol, domperidone and sulpiride competed for 3 H-prazosin binding in order of haloperidol > domperidone > dopamine > sulpiride. Metoclopramide, sulpiride and dopamine competed for 3 H-yohimbine binding in order of metoclopramide > sulpiride > dopamine

  11. Cerenkov counting and Cerenkov-scintillation counting with high refractive index organic liquids using a liquid scintillation counter

    International Nuclear Information System (INIS)

    Wiebe, L.I.; Helus, F.; Maier-Borst, W.

    1978-01-01

    18 F and 14 C radioactivity was measured in methyl salicylate (MS), a high refractive index hybrid Cherenkov-scintillation generating medium, using a liquid scintillation counter. At concentrations of up to 21.4%, in MS, dimethyl sulfoxide (DMSO) quenched 14 C fluorescence, and with a 10-fold excess of DMSO over MS, 18 F count rates were reduced below that for DMSO alone, probably as a result of concentration-independent self-quenching due to 'dark-complex' formation. DMSO in lower concentrations did not reduce the counting efficiency of 18 F in MS. Nitrobenzene was a concentration-dependent quencher for both 14 C and 18 F in MS. Chlorobenzene (CB) and DMSO were both found to be weak Cherenkov generators with 18 F. Counting efficiencies for 18 F in MS, CB, and DMSO were 50.3, 7.8 and 4.3% respectively in the coincidence counting mode, and 58.1, 13.0 and 6.8% in the singles mode. 14 C efficiencies were 14.4 and 22.3% for coincidence and singles respectively, and 15.3 and 42.0% using a modern counter designed for coincidence and single photon counting. The high 14 C and 18 F counting efficiency in MS are discussed with respect to excitation mechanism, on the basis of quench and channels ratios changes observed. It is proposed that MS functions as an efficient Cherenkov-scintillation generator for high-energy beta emitters such as 18 F, and as a low-efficiency scintillator for weak beta emitting radionuclides such as 14 C. (author)

  12. Preliminary results of the alpha particle registration intercomparison ALRIT

    International Nuclear Information System (INIS)

    Paretzke, H.G.

    1976-01-01

    In view of the widespread interest in alpha particle registration with solid state nuclear track detectors, an international intercomparison of such measurements has been arranged. Sixteen sets of fourteen detectors each were sent to GSF-Neuherberg, there irradiated carefully with different alpha particle fields, and then returned for evaluation. Fourteen irradiation runs were made for each set simulating seven different irradiation situations commonly encountered in practical applications. The preliminary results of this intercomparison reported in this paper are based on the results of eight sets. They show good agreement with respect to the determination of track densities in the case of vertical incident alpha particles. Also the results obtained for determination of particle energies and angle of incidence in most cases were rather accurate. However, apparently it is still rather difficult to determine accurately and precisely the specific activity of alpha emitters on a thick filter positioned at some distance, i.e. for the case of 2π-incidence and a broad energy spectrum. (orig.) [de

  13. Kinetic Stability May Determine the Interaction Dynamics of the Bifunctional Protein DCoH1, the Dimerization Cofactor of the Transcription Factor HNF-1[alpha

    Energy Technology Data Exchange (ETDEWEB)

    Rho, H.; Jones, C.N.; Rose, R.B. (NCSU)

    2010-12-07

    The two disparate functions of DCoH1 (dimerization cofactor of HNF-1)/PCD (pterin-4a-carbinolamine dehydratase) are associated with a change in oligomeric state. DCoH dimers enhance the activity of the diabetes-associated transcription factor HNF-1{alpha} (hepatocyte nuclear factor-1{alpha}), while the PCD activity of DCoH1 homotetramers aids in aromatic amino acid metabolism. These complexes compete for the same interface of the DCoH dimer. Formation of the DCoH1/HNF-1{alpha} complex requires cofolding. The homotetramer of the DCoH1 paralogue, DCoH2, interacts with HNF-1{alpha} through simple mixing. To further investigate regulation of DCoH/HNF-1{alpha} complex formation, we measured the stability of the DCoH1 homotetramer through unfolding studies by intrinsic tryptophan fluorescence. DCoH2 unfolding is reversible. Surprisingly, the DCoH1 homotetramer is resistant to guanidine unfolding but refolds at a much lower guanidine concentration. We show that a point mutation at the DCoH1 tetramer interface, Thr 51 Ser, overcomes the dissociation barrier of the homotetramer and increases the interaction with HNF-1{alpha}. The 1.8 {angstrom} resolution crystal structure of DCoH1 T51S shows the presence of an ordered water molecule at the tetramer interface, as in DCoH2, which may destabilize the homotetramer. The equilibrium unfolding data were fit to a two-state model with no apparent intermediate. Folding intermediates were detectable by size exclusion chromatography. For wild-type DCoH1 the intermediates changed with time, suggesting a kinetic origin for the unfolding barrier of the homotetramer. We propose an unfolding pathway in which the tetramer unfolds slowly, but the dimer folds reversibly. Implications for regulation of DCoH1/HNF-1{alpha} complex formation are discussed.

  14. Effect of Photon Hormesis on Dose Responses to Alpha Particles in Zebrafish Embryos

    Directory of Open Access Journals (Sweden)

    Candy Yuen Ping Ng

    2017-02-01

    Full Text Available Photon hormesis refers to the phenomenon where the biological effect of ionizing radiation with a high linear energy transfer (LET value is diminished by photons with a low LET value. The present paper studied the effect of photon hormesis from X-rays on dose responses to alpha particles using embryos of the zebrafish (Danio rerio as the in vivo vertebrate model. The toxicity of these ionizing radiations in the zebrafish embryos was assessed using the apoptotic counts at 20, 24, or 30 h post fertilization (hpf revealed through acridine orange (AO staining. For alpha-particle doses ≥ 4.4 mGy, the additional X-ray dose of 10 mGy significantly reduced the number of apoptotic cells at 24 hpf, which proved the presence of photon hormesis. Smaller alpha-particle doses might not have inflicted sufficient aggregate damages to trigger photon hormesis. The time gap T between the X-ray (10 mGy and alpha-particle (4.4 mGy exposures was also studied. Photon hormesis was present when T ≤ 30 min, but was absent when T = 60 min, at which time repair of damage induced by alpha particles would have completed to prevent their interactions with those induced by X-rays. Finally, the drop in the apoptotic counts at 24 hpf due to photon hormesis was explained by bringing the apoptotic events earlier to 20 hpf, which strongly supported the removal of aberrant cells through apoptosis as an underlying mechanism for photon hormesis.

  15. Longitudinal emittance measurement at the ATS

    International Nuclear Information System (INIS)

    Cottingame, W.B.; Cortez, J.H.; Higgins, W.W.; Sander, O.R.; Sandoval, D.P.

    1986-01-01

    With increasing brightness, beam diagnostic techniques requiring interception of the beam become impractical. For H - particle beams, solutions for this problem based on the phenomenon of photodissociation are now being investigated at the Los Alamos National Laboratory accelerator test stand (ATS). A laser can be used to selectively neutralize portions of the beam than can be characterized after the charged particles have been swept away. We have used this technique for measuring longitudinal emittance at the output of the ATS radio-frequency quadrupole

  16. No-carrier-added (NCA) synthesis of 6-[{sup 18}F]fluoro-L-DOPA using 3,5,6,7,8,8a-hexahydro-7,7,8a-trimethyl-[6S-(6{alpha}, 8{alpha}, 8{alpha}{beta})]-6,8-methano-2H-1,4-benzoxazin-2-one

    Energy Technology Data Exchange (ETDEWEB)

    Horti, A. [Yale Univ., New Haven, CT (United States). School of Medicine]|[Yale Univ., West Haven, CT (United States). PET Center; Redmond, D.E. Jr. [Yale Univ., New Haven, CT (United States). School of Medicine; Soufer, R. [Yale Univ., West Haven, CT (United States). PET Center

    1995-12-31

    3,5,6,7,8,8a-Hexahydro-7,7,8a-trimethyl-[6S-(6{alpha},8{alpha} , 8{alpha}{beta})]-6,8-methano-2H-1,4-benzoxazino-2-one (2) was investigated as chiral auxiliary for asymmetric NCA nucleophilic synthesis of 6-[{sup 18}F]Fluoro-L-DOPA. Direct condensation of 3,4-dimethoxy-2-[{sup 18}F]fluorobenzaldehyde (1a) or 6-[{sup 18}F]fluoro-piperonal (1b) in the presence of NaH with 2 gave the corresponding [{sup 18}F]-3-[(2-fluorophenyl)methylene]-3,5,6,7,8,8a-hexahydro-7,7,8 a-trimethyl-[6S-(3Z,3{alpha},6{alpha},8{alpha},8{alpha}{beta})]-6, 8-methano-2H-1,4-benzoxazin-2-one derivative 3a or 3b as a single stereoisomer. L-Selectride promoted hydrogenation of the olefinic double bond of these derivatives, in presence of tertbutyl alcohol, afforded the corresponding [{sup 18}F]-3-[(2-fluorophenyl) methyl]-3,5,6,7,8,8a-hexahydro-7,7,8a-trimethyl-[3S-(3{alpha}, 6{alpha}, 8{alpha}8{alpha}{beta})]-6,8-methano-2H-1,4-benzoxazin-2-one derivatives (4a,b) without affecting the orientation of diasterofacial discrimination. Deprotection of the derivatives 4a,b yielded 6-[{sup 18}F]fluoro-L-DOPA (e.e. >90%, 3% radiochemical yield (EOB), total synthesis time 125 min, specific activity >2000 mCi/{mu}mol). Direct deprotection/reduction of the compounds 3a,b provides the enantiomeric mixture of 6-[{sup 18}F]fluoro-D,L-DOPA (10-12% radiochemical yield) and, after chiral separation, 6-[{sup 18}F]fluoro-L-DOPA (e.e. 98%, 4-5% radiochemical yield). (author).

  17. Alpha decay calculations with a new formula

    International Nuclear Information System (INIS)

    Akrawy, D T; Poenaru, D N

    2017-01-01

    A new semi-empirical formula for calculations of α  decay half-lives is presented. It was derived from the Royer relationship by introducing new parameters which are fixed by fit to a set of experimental data. We are using three sets: set A with 130 e–e (even–even), 119 e–o (even–odd), 109 o–e, and 96 o–o, set B with 188 e–e, 147 e–o, 131 o–e and 114 o–o, and set C with 136 e–e, 84 e–o, 76 o–e and 48 o–o alpha emitters. A comparison of results obtained with the new formula (newF) and the following well known relationships: semiempirical relationship based on fission theory (semFIS), analytical superasymmetric fission (ASAF) model and universal formula (UNIV) made in terms of rms standard deviation. We also introduced a weighted mean value of this quantity, allowing us to compare the global properties of a given model. For set B the order of the four models is the following: semFIS, UNIV, newF and ASAF. Nevertheless for even–even alpha emitters, UNIV gives the second best result after semFIS, and for odd–even parents the second is newF. Despite its simplicity in comparison with semFIS, newF, presented in this article, behaves quite well, competing with the other well known relationships. (paper)

  18. Diamond-based single-photon emitters

    International Nuclear Information System (INIS)

    Aharonovich, I; Castelletto, S; Simpson, D A; Su, C-H; Greentree, A D; Prawer, S

    2011-01-01

    The exploitation of emerging quantum technologies requires efficient fabrication of key building blocks. Sources of single photons are extremely important across many applications as they can serve as vectors for quantum information-thereby allowing long-range (perhaps even global-scale) quantum states to be made and manipulated for tasks such as quantum communication or distributed quantum computation. At the single-emitter level, quantum sources also afford new possibilities in terms of nanoscopy and bio-marking. Color centers in diamond are prominent candidates to generate and manipulate quantum states of light, as they are a photostable solid-state source of single photons at room temperature. In this review, we discuss the state of the art of diamond-based single-photon emitters and highlight their fabrication methodologies. We present the experimental techniques used to characterize the quantum emitters and discuss their photophysical properties. We outline a number of applications including quantum key distribution, bio-marking and sub-diffraction imaging, where diamond-based single emitters are playing a crucial role. We conclude with a discussion of the main challenges and perspectives for employing diamond emitters in quantum information processing.

  19. A New Design Strategy for Efficient Thermally Activated Delayed Fluorescence Organic Emitters: From Twisted to Planar Structures

    KAUST Repository

    Chen, Xiankai

    2017-10-17

    In the traditional molecular design of thermally activated delayed fluorescence (TADF) emitters composed of electron-donor and electron-acceptor moieties, achieving a small singlet-triplet energy gap (ΔEST ) in strongly twisted structures usually translates into a small fluorescence oscillator strength, which can significantly decrease the emission quantum yield and limit efficiency in organic light-emitting diode devices. Here, based on the results of quantum-chemical calculations on TADF emitters composed of carbazole donor and 2,4,6-triphenyl-1,3,5-triazine acceptor moieties, a new strategy is proposed for the molecular design of efficient TADF emitters that combine a small ΔEST with a large fluorescence oscillator strength. Since this strategy goes beyond the traditional framework of structurally twisted, charge-transfer type emitters, importantly, it opens the way for coplanar molecules to be efficient TADF emitters. Here, a new emitter, composed of azatriangulene and diphenyltriazine moieties, is theoretically designed, which is coplanar due to intramolecular H-bonding interactions. The synthesis of this hexamethylazatriangulene-triazine (HMAT-TRZ) emitter and its preliminary photophysical characterizations point to HMAT-TRZ as a potential efficient TADF emitter.

  20. Studies on the characterization and regulation of alpha-1 adrenergic receptors and [3H]WB4101 binding sites in the central nervous system

    International Nuclear Information System (INIS)

    Morrow, A.L.

    1985-01-01

    The purpose of these studies has been to resolve the anomalous binding characteristics of two alpha adrenergic receptor ligands, [ 3 H]WB4101 and [ 3 H]prazosin and to study the regulation of the receptors labeled by these compounds after surgical denervation and chronic drug treatments. Preliminary studies indicated that [ 3 H]WB4101 binding sites, which were believed to represent alpha-1 adrenergic receptors, were increased in number following removal of the fimbrial afferents to the hippocampus. This increase was not due to removal of the adrenergic input into this structure since destruction of the locus coeruleus or the dorsal noradrenergic bundle did not produce the up-regulation. Characterization of alpha-1 adrenergic receptors using [ 3 H]prazosin and [ 3 H]WB4101 revealed evidence for subtypes of alpha-1 receptors designated alpha-1A and alpha-1B. The nanomolar affinity component of [ 3 H]WB4101 binding is not adrenergic but serotonergic. The serotonergic agonists, serotonin and 8-hydroxy-dipropylaminotetraline have affinities of 1.5 and 3.0 nM for this site, when studied in the presence of a 30 nM prazosin mask of the alpha-1 component of [ 3 H]WB4101 binding. Fimbria transection or 5,7 dihydroxytryptamine injections produced increases in the Bmax of the nanomolar affinity component of [ 3 H]WB4101 binding in the presence of a prazosin mask. The up-regulated site showed identical serotonergic pharmacology compared to control tissue. Thus, the author concluded that serotonergic denervation of the hippocampus produces the increase in serotonergic binding sites labeled by [ 3 H]WB4101

  1. Emittance compensation of CW DC-gun photoinjector

    International Nuclear Information System (INIS)

    Li Peng; Wu Dai; Xu Zhou; Li Ming; Yang Xingfan

    2011-01-01

    Emittance growth induced by space charge effect is very important, especially for CW DC-gun photoinjector. In this work, the linear space charge force and its effect on electron beam transverse emittance are studied, and the principle and properties of emittance compensation by solenoid are analyzed. The CAEP DC-gun photoinjector with a solenoid is also simulated by code Parmela. Simulated results indicate that the normalized transverse emittance of an 80 pC bunch at the 350 keV DC-gun ex-it is 5.14 mm · mrad. And after compensated by a solenoid, it becomes 1.27 mm · mrad. The emittance of beam is well compensated. (authors)

  2. A low-emittance lattice for SPEAR

    International Nuclear Information System (INIS)

    Safranek, J.; Wiedemann, H.

    1992-01-01

    The design and implementation of a low emittance lattice for the SPEAR storage ring including measurements of the performance of the lattice are presented (J. Safranek, Ph. D. thesis, Stanford University, 1991). The low emittance lattice is designed to optimize the performance of SPEAR as a synchrotron radiation source while keeping SPEAR hardware changes at a minimum. The horizontal emittance of the electron beam in the low emittance lattice is reduced by a factor of 4 from the previous lattice. This reduces the typical horizontal source size and divergence of the photon beams by a factor of 2 each and increases the photon beam brightness. At 3 GeV the horizontal emittance is 129 π nm rad, which makes the low emittance lattice the lowest emittance, runnning synchroton radiation source in the world in the 1.5 to 4.0 GeV energy range for the emittance scaled to 3 GeV. The measured vertical emittance was reduced to half that typically seen at SPEAR in the past. The brightness of the photon beams was further incrased by reducing β y at the insertion devices to 1.1 m and reducing the energy dispersion at the insertion devices by more than a factor of 2 on average. The horizontal despersion at the rf cavities was reduced by a factor of nearly 4 which gives much less problems with synchrobetatron resonances. The dynamic and physical apertures of the lattice are large, giving long beam lifetimes and easy injection of electrons. The measurements of the linear optics and intensity dependent phenomena gave resonable agreement with the design . The overall performance of the machine was very good. Injection rates of 10 to 20 mA/min and larger were achieved routinely, and 100 mA total current was stored. Repeated ramping of stored beam from the injection energy of 2.3 GeV to the running energy of 3.0 GeV was achieved with very little beam loss. This low emittance configuration is expected to be the operating configuration for SPEAR starting in January 1992. (orig.)

  3. Radiation emitter-detector package

    International Nuclear Information System (INIS)

    O'Brien, J.T.; Limm, A.C.; Nyul, P.; Tassia, V.S. Jr.

    1978-01-01

    Mounted on the metallic base of a radiation emitter-detector is a mounting block is a first projection, and a second projection. A radiation detector is on the first projection and a semiconductor electroluminescent device, i.e., a radiation emitter, is on the second projection such that the plane of the recombination region of the electroluminescent device is perpendicular to the radiation incident surface of the radiation detector. The electroluminescent device has a primary emission and a secondary emission in a direction different from the primary emission. A radiation emitter-detector package as described is ideally suited to those applications wherein the secondary radiation of the electroluminescent device is fed into a feedback circuit regulating the biasing current of the electroluminescent device

  4. The effect of alpha-thalassemia on cord blood red cell indices and interaction with sickle cell gene

    International Nuclear Information System (INIS)

    Quadri, Mohammad I.; Islam, Sherief I.A.M.; Nasserullah, Z.

    2000-01-01

    Alpha-thalassemia is known to be prevalent in the Eastern region of Saudi Arabia. There are no large scale reports regarding the effect of alpha-thalassemia on red cell indices of cord blood from Saudi Arabia. Similarly, there are reports regarding the interaction of alpha-thalassemia and the sickle-cell gene in relation to red cell indices in cord blood. To address these issues, we undertook a study on neonatal cold blood samples. In a prospective study, cord blood samples from 504 neonates from the Qatif area of the Eastern Province of Saudi Arabia were analyzed for complete blood counts (CBC) and cellulose acetate Hb electrophoresis. Hb S was confirmed by citrate agar Hb electrophoresis. There were 243 case samples with normal Hb electrophoresis (Hb A 27.2+- 7% and Hb F 72.6+-7.7%). Their mean Hb (g/dL), RBC (x10/L), Hct (%), MCV (pg), MCHC (g/dL), RDW-SD (fl) and RDW-CV (%) were 15.05+-1.6, 4.5+-0.5, 47.4+-5.3, 106+-8, 33.6+-2.3, 31.8+-1.7, 69.2+-9.5 and 17.9+-1.7, respectively. There were 136 cases with alpha-thalassemia trait (alphaTT), 57 cases with sickle cell trait (SCT) and 50 cases of sickle cell trait with alplha-thalassemia trait (SCT/ alphaTT). There were ten cases of Hb H disease (6 definite), including one with sickle cell disease (SCD) and two with SCT, Hb Bart's 23.9%-43.6%; four probable with Hb Bart's 10.9%-16.1% and one with SCT. The effect on red cell parameters in Hb H disease were most pronounced. In addition, there seven cases of SCD, four of whom had coexistent alpha-thalassemia trait (SCD/alphaTT). The prevalence of alpha-thalassemia in this cohort of Saudi population was 39.99%. Hb H disease appeared as common as SCD. Sickle cell gene was seen in 23.4% of neonatal samples. Apha-thalassemia gene significantly reduces MCH, MCV, RDW-SD, Hct, Hb and increase RBC count in both normal or sickle cell trait neonates. Generally, the variation of red cell parameters is directly proportional to the amount of Hb Bart's in the cord blood. Sickle cell

  5. Emittance investigation of RF photo-injector

    CERN Document Server

    Yang Mao Rong; Li Zheng; Li Ming; Xu Zhou

    2002-01-01

    A high-power laser beam illuminates a photocathode surface placed on an end wall of an RF cavity. The emitted electrons are accelerated immediately to a relativistic energy by the strong RF find in the cavity. But space charge effect induces beam emittance growth especially near the cathode where the electrons are still nonrelativistic. The author analyzes the factors which lead the transverse emittance growth and method how to resolve this problem. After introducing solenoidal focusing near the photocathode, the beam emittance growth is suppressed dramatically. The beam emittance is given also after compensation and simulation results. The measurements show these results are coincident

  6. Kinetic properties of /sup 3/H-16. cap alpha. -gitoxin in the isolated guinea-pig atrium

    Energy Technology Data Exchange (ETDEWEB)

    Haustein, K O; Glusa, E [Medizinische Akademie, Erfurt (German Democratic Republic)

    1978-04-01

    The accumulation and the loss of (/sup 3/H)-16..cap alpha..-gitoxin were estimated in correlation with its positive inotropic effect using the isolated spontaneously beating guinea-pig atrium. The properties of 16..cap alpha..-gitoxin were compared with those of (/sup 3/H)-ouabain and (/sup 3/H)-digitoxin. The experiments were performed with positive inotropic equieffective glycoside concentrations. During a 2-hr incubation period, 16..cap alpha..-gitoxin was accumulated to a low extent (2.05 nmoles per g w.w., tissue/medium (T/M) ratio =0.66). Similar results were obtained with ouabain (47.5 pmoles per g w.w.; T/M ratio = 0.51), while digitoxin was accumulated to a high extent (266 pmoles per g w.w.; T/M ratio = 2.98). Wash-out experiments demonstrated that the inotropic effect disappears more rapidly than the loss of tissue radioactivity occurred, the effects of 16..cap alpha..-gitoxin were diminished more easily after wash-out than those of ouabain and digitoxin. In the presence of 1.0 instead of 0.1 vol-% dimethylformamide, both the accumulation of radioactivity (5.0 nmoles per g w.w.; T/M ratio = 1.58) and the positive inotropic effect are enhanced. From the experiments it was concluded: (1) 16..cap alpha..-gitoxin has similar kinetic properties as ouabain. (2) The concentration of dimethylformamide used influences the kinetic behaviour on the tissue level. (3) No correlation exists neither between the extent of the positive inotropic effect and theamount of accumulated glycoside, nor between the loss of tissue radioactivity and the disappearance of positive inotropic effect.

  7. Analysis of the local kinetics and localization of interleukin-1 alpha, tumour necrosis factor-alpha and transforming growth factor-beta, during the course of experimental pulmonary tuberculosis.

    Science.gov (United States)

    Hernandez-Pando, R; Orozco, H; Arriaga, K; Sampieri, A; Larriva-Sahd, J; Madrid-Marina, V

    1997-01-01

    A mouse model of pulmonary tuberculosis induced by the intratracheal instillation of live and virulent mycobacteria strain H37-Rv was used to examine the relationship of the histopathological findings with the local kinetics production and cellular distribution of tumour necrosis factor-alpha (TNF-alpha), interleukin-1 alpha (IL-1 alpha) and transforming growth factor-beta (TGF-beta). The histopathological and immunological studies showed two phases of the disease: acute or early and chronic or advanced. The acute phase was characterized by inflammatory infiltrate in the alveolar-capillary interstitium, blood vessels and bronchial wall with formation of granulomas. During this acute phase, which lasted from 1 to 28 days, high percentages of TNF-alpha and IL-1 alpha immunostained activated macrophages were observed principally in the interstium-intralveolar inflammatory infiltrate and in granulomas. Electron microscopy studies of these cells, showed extensive rough endoplasmic reticulum, numerous lysosomes and occasional mycobacteria. Double labelling with colloid gold showed that TNF-alpha and IL-1 alpha were present in the same cells, but were confined to separate vacuoles near the Golgi area, and mixed in larger vacuoles near to cell membrane. The concentration of TNF-alpha and IL-1 alpha as well as their respective mRNAs were elevated in the early phase, particularly at day 3 when the bacillary count decreased. A second peak was seen at days 14 and 21-28 when granulomas appeared and evolved to full maturation. In contrast, TGF-beta production and numbers of immunoreactive cells were low in comparison with the advanced phase of the disease. The chronic phase was characterized by histopathological changes indicative of more severity (i.e. pneumonia, focal necrosis and extensive interstitial fibrosis) with a decrease in the TNF-alpha and IL-1 alpha production that coincided with the highest level of TGF-beta. The bacillary counts were highest as the macrophages

  8. Strong Coupling and Entanglement of Quantum Emitters Embedded in a Nanoantenna-Enhanced Plasmonic Cavity

    Energy Technology Data Exchange (ETDEWEB)

    Hensen, Matthias [Institut; Heilpern, Tal [Center; Gray, Stephen K. [Center; Pfeiffer, Walter [Fakultät

    2017-10-12

    Establishing strong coupling between spatially separated and thus selectively addressable quantum emitters is a key ingredient to complex quantum optical schemes in future technologies. Insofar as many plasmonic nanostructures are concerned, however, the energy transfer and mutual interaction strength between distant quantum emitters can fail to provide strong coupling. Here, based on mode hybridization, the longevity and waveguide character of an elliptical plasmon cavity are combined with intense and highly localized field modes of suitably designed nanoantennas. Based on FDTD simulations a quantum emitter-plasmon coupling strength hg = 16.7 meV is reached while simultaneously keeping a small plasmon resonance line width h gamma(s) = 33 meV. This facilitates strong coupling, and quantum dynamical simulations reveal an oscillatory exchange of excited state population arid a notable degree of entanglement between the quantum emitters spatially separated by 1.8 mu m, i.e., about twice the operating wavelength.

  9. Criteria for emittance compensation in high-brightness photoinjectors

    Directory of Open Access Journals (Sweden)

    Chun-xi Wang

    2007-10-01

    Full Text Available A critical process in high-brightness photoinjectors is emittance compensation, which brings under control the correlated transverse emittance growth due to the linear space-charge force. Although emittance compensation has been used and studied for almost two decades, the exact criteria to achieve emittance compensation is not as clear as it should be. In this paper, a perturbative analysis of slice envelopes and emittance evolution close to any reference envelope is developed, via which space-charge and chromatic effects are investigated. A new criterion for emittance compensation is found, which is complementary to the well-known matching condition for the invariant envelope and agrees very well with simulations.

  10. Distributed plastic optical fibre measurement of pH using a photon counting OTDR

    International Nuclear Information System (INIS)

    Saunders, C; Scully, P J

    2005-01-01

    Distributed measurement of pH was demonstrated at a sensitised region 4m from the distal end of a 20m length of plastic optical fibre. The cladding was removed from the fibre over 150mm and the bare core was exposed to an aqueous solution of methyl red at three values of pH, between 2.89 and 9.70. The optical fibre was interrogated at 648nm using a Luciol photon counting optical time domain reflectometer, and demonstrated that the sensing region was attenuated as a function of pH. The attenuation varied from 16.3 dB at pH 2.89 to 8.6 dB at pH 9.70; this range equated to -1.13 ± 0.04 dB/pH. It is thus possible to determine both the position to ± 12mm and pH to an estimated ± 0.5pH at the sensing region

  11. Small horizontal emittance in the TESLA damping ring

    International Nuclear Information System (INIS)

    Decking, W.

    2001-01-01

    The present TESLA damping ring is designed for a normalized horizontal emittance of 8x10 -6 m. γ-γ collisions at the TESLA linear collider will benefit from a further decrease of the horizontal emittance. This paper reviews the processes which limit the horizontal emittance in the damping ring. Preliminary estimates on the smallest horizontal emittance for the present TESLA damping ring design as well as an ultimate limit of the emittance reachable with the TESLA damping ring concept will be given

  12. Counting efficiency for liquid scintillator systems with a single multiplier phototube; Eficiencia de recuento en espectrometros de centelleo con un solo fotomultiplicador

    Energy Technology Data Exchange (ETDEWEB)

    Grau Malonda, A; Garcia-Torano, E

    1984-07-01

    In this paper counting efficiency as a function of a free parameter (the figure of merit) has been computed. The results are applicable to liquid scintillator systems with a single multiplier phototube. Tables of counting efficiency for 62 pure beta emitters are given for figures of merit in the range 0.25 to 50. (Author) 16 refs.

  13. Beam diagnostics using an emittance measurement device

    International Nuclear Information System (INIS)

    Sarstedt, M.; Becker, R.; Klein, H.; Maaser, A.; Mueller, J.; Thomae, R.; Weber, M.

    1995-01-01

    For beam diagnostics aside from Faraday cups for current measurements and analysing magnets for the determination of beam composition and energy the most important tool is an emittance measurement device. With such a system the distribution of the beam particles in phase-space can be determined. This yields information not only on the position of the particles but also on their angle with respect to the beam axis. There are different kinds of emittance measurement devices using either circular holes or slits for separation of part of the beam. The second method (slit-slit measurement), though important for the determination of the rms-emittance, has the disadvantage of integrating over the y- and y'-coordinate (measurement in xx'-plane assumed). This leads to different emittance diagrams than point-point measurements, since in xx'-plane for each two corresponding points of rr'-plane there exists a connecting line. With regard to beam aberrations this makes xx'-emittances harder to interpret. In this paper the two kinds of emittance diagrams are discussed. Additionally the influence of the slit height on the xx'-emittance is considered. The analytical results are compared to experimental measurements in rr'-, rx'- and xx'-phase-space. (orig.)

  14. A digital miniature x-ray tube with a high-density triode carbon nanotube field emitter

    International Nuclear Information System (INIS)

    Jeong, Jin-Woo; Kang, Jun-Tae; Choi, Sungyoul; Kim, Jae-Woo; Song, Yoon-Ho; Ahn, Seungjoon

    2013-01-01

    We have fabricated a digital miniature x-ray tube (6 mm in diameter and 32 mm in length) with a high-density triode carbon nanotube (CNT) field emitter for special x-ray applications. The triode CNT emitter was densely formed within a diameter of below 4 mm with the focusing-functional gate. The brazing process enables us to obtain and maintain a desired vacuum level for the reliable electron emission from the CNT emitters after the vacuum packaging. The miniature x-ray tube exhibited a stable and reliable operation over 250 h in a pulse mode at an anode voltage of above 25 kV.

  15. Binding of benzo(a)pyrene and (+/-)-7 beta,8 alpha-dihydroxy-9 alpha, 10 alpha-epoxy-7,8,9, 10-tetrahydrobenzo(a)pyrene to histones

    International Nuclear Information System (INIS)

    Sculley, T.B.; Zytkovicz, T.H.

    1983-01-01

    AKR-2B mouse embryo cells were incubated for 24 hr with [3H]benzo(a)pyrene, and the histones were isolated and analyzed using one- and two-dimensional gel electrophoresis and autoradiography. The results revealed that (a) histones H1, H2A, and H3 incorporated significant amounts of label whereas little or no label was associated with histones H2B and H4 and (b) electrophoresis of the histones in the Triton: acid: urea gel system caused labeled histones to have a slower migration than did the corresponding unlabeled histones. Additional studies such as incubation of (+/-)-7 beta,8 alpha-[3H]dihydroxy-9 alpha,10 alpha-epoxy-7,8,9,10-tetrahydrobenzo(a)pyrene with nuclei resulted in radioactive labeling of histones H1, H2A, H2B, and H3 and of high-mobility-group proteins HMG1 and HMG2. The low levels of label associated with histone H4 in the whole-cell and nuclear studies were further investigated by incubating isolated histones with (+/-)-7 beta,8 alpha-[3H]dihydroxy-9 alpha,10 alpha-epoxy-7,8,9,10-tetrahydrobenzo(a)pyrene. Under these conditions, negligible amounts of radioactivity were associated with H4, while significant labeling of H1, H2A, H2B, and H3 and other nuclear proteins was observed. The results suggest that factors other than the presence of suitable nucleophilic acceptor sites on the histones may be necessary for carcinogen binding

  16. Performance of gamma spectrometry counting system

    International Nuclear Information System (INIS)

    Yii Mei Wo; Maziah Mahmud

    2007-01-01

    Gamma spectrometry counting system widely used as tool to measure qualitative and quantitative gamma-ray emitters in a sample. Container size, sample to detector distance, sample volume are well known factors that affecting the quality of measurement. However, factor such as the age of the system was not been reported. Therefore, the objective of this study is to find out how the age factor affecting the quality of the measurement. From this study, it is found that when the age of the system increased, the system tends to have higher lower limit of detection and poorer linearity showing that age factor do affecting the quality of measurement. (Author)

  17. Direct chemical synthesis of 1 alpha,25-dihydroxy[26,27-3H] vitamin D3 with high specific activity: its use in receptor studies

    International Nuclear Information System (INIS)

    Napoli, J.L.; Mellon, W.S.; Fivizzani, M.A.; Schnoes, H.K.; DeLuca, H.F.

    1980-01-01

    The first direct chemical synthesis of radiolabeled 1 alpha, 25-dihydroxyvitamin D3 is reported. Unlike all previous syntheses, the new approach does not rely on enzymatic 1 alpha-hydroxylation of radiolabeled precursors. Rather, isotope is introduced in the last synthetic step by reaction of [3H] -methylmagnesium bromide with methyl 1 alpha-hydroxy-26,27-dinorvitamin D3-25-carboxylate to give 1 alpha,25-dihydroxy-[26,27-3H] vitamin D3 with a specific activity of 160 Ci/mmol. Mass spectroscopy confirmed that the radiohormone consists of a single isomer with six tritium atoms bound to carbons 26 and 27. Synthetically produced 1 alpha,25-dihydroxy [26,27-3H] vitamin D3 is indistinguishable from 1 alpha,25-dihydroxy-[26,27-3H] vitamin D3 obtained from the enzymatic 1 alpha-hydroxylation of 25-hydroxy[26,27-3H] vitamin D3 (160 Ci/mmol) by high-pressure liquid chromatography analysis and in the competitive binding assay using chick intestinal cytosol as the receptor source. Equilibrium dissociation constant measurements with the high specific activity radiohormone indicate a Kd of 8.2 x 10(-11) M for the chick intestinal cytosol 1 alpha,25-dihydroxyvitamin D3 receptor--a value considerably lower than the constants in the range of (1-5) x 10(-9) M previously reported

  18. Nonintercepting emittance monitor

    International Nuclear Information System (INIS)

    Miller, R.H.; Clendenin, J.E.; James, M.B.; Sheppard, J.C.

    1983-08-01

    A nonintercepting emittance monitor is a helpful device for measuring and improving particle beams in accelerators and storage rings as it allows continuous monitoring of the beam's distribution in phase space, and perhaps closed loop computer control of the distributions. Stripline position monitors are being investigated for use as nonintercepting emittance monitors for a beam focused by a FODO array in the first 100 meters of our linear accelerator. The technique described here uses the signal from the four stripline probes of a single position monitor to measure the quadrupole mode of the wall current in the beam pipe. This current is a function of the quadrupole moment of the beam, sigma 2 /sub x/ - sigma 2 /sub y/. In general, six independent measurements of the quadrupole moment are necessary to determine the beam emittance. This technique is dependent on the characteristically large variations of sigma 2 /sub x/ - sigma 2 /sub y/ in a FODO array. It will not work in a focusing system where the beam is round at each focusing element

  19. White blood cell counts and neutrophil to lymphocyte ratio in the diagnosis of testicular cancer: a simple secondary serum tumor marker.

    Science.gov (United States)

    Yuksel, Ozgur Haki; Verit, Ayhan; Sahin, Aytac; Urkmez, Ahmet; Uruc, Fatih

    2016-01-01

    The aim of the study was to investigate white blood cell counts and neutrophil to lymphocyte ratio (NLR) as markers of systemic inflammation in the diagnosis of localized testicular cancer as a malignancy with initially low volume. Thirty-six patients with localized testicular cancer with a mean age of 34.22±14.89 years and 36 healthy controls with a mean age of 26.67±2.89 years were enrolled in the study. White blood cell counts and NLR were calculated from complete blood cell counts. White blood cell counts and NLR were statistically significantly higher in patients with testicular cancer compared with the control group (ptesticular cancer besides the well-known accurate serum tumor markers as AFP (alpha fetoprotein), hCG (human chorionic gonadotropin) and LDH (lactate dehydrogenase).

  20. Low emittance configuration for spear

    International Nuclear Information System (INIS)

    Blumberg, L.N.; Harris, J.; Stege, R.; Cerino, J.; Hettel, R.; Hofmann, A.; Liu, R.Z.; Wiedemann, H.; Winick, H.

    1985-01-01

    The quality of synchrotron radiation beams from SPEAR, in particular the brilliance of undulator radiation, can be improved significantly by reducing the emittance of the stored electron beam. A reduction of the horizontal emittance by a factor of 3.5 to a value of 130 nanometer-radians (nm-r) at 3 GeV has been achieved by using stronger focussing, mainly in the horizontal plane. The low emittance configuration also reduces the dispersion and vertical beta functions in the straight sections, making them more suitable for wigglers. The higher betatron tunes lead to a larger phase advance between the two kickers, which has to be corrected during injection by shunting current from some quadrupoles. The configuration was optimized within SPEAR hardware limitations and tested for dynamic aperture with the tracking program PATRICIA. After implementation of this scheme, beam was successfully injected and accumulated. The measured emittance of the stored beam was in agreement with calculations. Presently the configuration is being made operational

  1. Emittance measurements by variable quadrupole method

    International Nuclear Information System (INIS)

    Toprek, D.

    2005-01-01

    The beam emittance is a measure of both the beam size and beam divergence, we cannot directly measure its value. If the beam size is measured at different locations or under different focusing conditions such that different parts of the phase space ellipse will be probed by the beam size monitor, the beam emittance can be determined. An emittance measurement can be performed by different methods. Here we will consider the varying quadrupole setting method.

  2. Alternate method of source preparation for alpha spectrometry: No electrodeposition, no hydrofluoric acid

    International Nuclear Information System (INIS)

    Kurosaki, Hiromu; Mueller, Rebecca J.; Lambert, Susan B.; Rao, Govind R.

    2016-01-01

    An alternate method of preparing actinide alpha counting sources was developed in place of electrodeposition or lanthanide fluoride micro-precipitation. The method uses lanthanide hydroxide micro-precipitation to avoid the use of hazardous hydrofluoric acid. Lastly, it provides a quicker, simpler, and safer way of preparing actinide alpha counting sources in routine, production-type laboratories that process many samples daily.

  3. Alternate method of source preparation for alpha spectrometry: no electrodeposition, no hydrofluoric acid

    International Nuclear Information System (INIS)

    Hiromu Kurosaki; Lambert, S.B.; Rao, G.R.; Mueller, R.J.

    2017-01-01

    An alternate method of preparing actinide alpha counting sources was developed in place of electrodeposition or lanthanide fluoride micro-precipitation. The method uses lanthanide hydroxide micro-precipitation to avoid the use of hazardous hydrofluoric acid. It provides a quicker, simpler, and safer way of preparing actinide alpha counting sources in routine, production-type laboratories that process many samples daily. (author)

  4. Low Emittance Growth in a LEBT with Un-Neutralized Section

    Energy Technology Data Exchange (ETDEWEB)

    Prost, L. [Fermilab; Carneiro, J.-P. [Fermilab; Shemyakin, A. [Fermilab

    2017-12-20

    In a Low Energy Beam Transport line (LEBT), the emittance growth due to the beam’s space charge is typically suppressed by way of neutralization from either electrons or ions, which originate from ionization of the background gas. In cases where the beam is chopped, the neutralization pattern usually changes throughout the beginning of the pulse, causing the Twiss parameters to differ significantly from their steady state values, which, in turn, may result in beam losses downstream. For a modest beam perveance, there is an alternative solution, in which the beam is kept un-neutralized in the portion of the LEBT that contains the chopper. The emittance can be nearly preserved if the transition to the un-neutralized section occurs where the beam exhibits low transverse tails. This report introduces the rationale for the proposed scheme and formulates the physical arguments for it as well as its limitations. An experimental realization of the scheme was carried out at Fermilab’s PIP2IT where low beam emittance dilution was demonstrated for a 5 mA, 30 keV H- beam.

  5. Cloning and Molecular Characterization of an Alpha-Glucosidase (MalH) from the Halophilic Archaeon Haloquadratum walsbyi.

    Science.gov (United States)

    Cuebas-Irizarry, Mara F; Irizarry-Caro, Ricardo A; López-Morales, Carol; Badillo-Rivera, Keyla M; Rodríguez-Minguela, Carlos M; Montalvo-Rodríguez, Rafael

    2017-11-21

    We report the heterologous expression and molecular characterization of the first extremely halophilic alpha-glucosidase (EC 3.2.1.20) from the archaeon Haloquadratum walsbyi . A 2349 bp region ( Hqrw_2071 ) from the Hqr. walsbyi C23 annotated genome was PCR-amplified and the resulting amplicon ligated into plasmid pET28b(+), expressed in E. coli Rosetta cells, and the resulting protein purified by Ni-NTA affinity chromatography. The recombinant protein showed an estimated molecular mass of 87 kDa, consistent with the expected value of the annotated protein, and an optimal activity for the hydrolysis of α-PNPG was detected at 40 °C, and at pH 6.0. Enzyme activity values were the highest in the presence of 3 M NaCl or 3-4 M KCl. However, specific activity values were two-fold higher in the presence of 3-4 M KCl when compared to NaCl suggesting a cytoplasmic localization. Phylogenetic analyses, with respect to other alpha-glucosidases from members of the class Halobacteria, showed that the Hqr. walsbyi MalH was most similar (up to 41%) to alpha-glucosidases and alpha-xylosidases of Halorubrum . Moreover, computational analyses for the detection of functional domains, active and catalytic sites, as well as 3D structural predictions revealed a close relationship with an E. coli YicI-like alpha-xylosidase of the GH31 family. However, the purified enzyme did not show alpha-xylosidase activity. This narrower substrate range indicates a discrepancy with annotations from different databases and the possibility of specific substrate adaptations of halophilic glucosidases due to high salinity. To our knowledge, this is the first report on the characterization of an alpha-glucosidase from the halophilic Archaea, which could serve as a new model to gain insights into carbon metabolism in this understudied microbial group.

  6. Cloning and Molecular Characterization of an Alpha-Glucosidase (MalH from the Halophilic Archaeon Haloquadratum walsbyi

    Directory of Open Access Journals (Sweden)

    Mara F. Cuebas-Irizarry

    2017-11-01

    Full Text Available We report the heterologous expression and molecular characterization of the first extremely halophilic alpha-glucosidase (EC 3.2.1.20 from the archaeon Haloquadratum walsbyi. A 2349 bp region (Hqrw_2071 from the Hqr. walsbyi C23 annotated genome was PCR-amplified and the resulting amplicon ligated into plasmid pET28b(+, expressed in E. coli Rosetta cells, and the resulting protein purified by Ni-NTA affinity chromatography. The recombinant protein showed an estimated molecular mass of 87 kDa, consistent with the expected value of the annotated protein, and an optimal activity for the hydrolysis of α-PNPG was detected at 40 °C, and at pH 6.0. Enzyme activity values were the highest in the presence of 3 M NaCl or 3–4 M KCl. However, specific activity values were two-fold higher in the presence of 3–4 M KCl when compared to NaCl suggesting a cytoplasmic localization. Phylogenetic analyses, with respect to other alpha-glucosidases from members of the class Halobacteria, showed that the Hqr. walsbyi MalH was most similar (up to 41% to alpha-glucosidases and alpha-xylosidases of Halorubrum. Moreover, computational analyses for the detection of functional domains, active and catalytic sites, as well as 3D structural predictions revealed a close relationship with an E. coli YicI-like alpha-xylosidase of the GH31 family. However, the purified enzyme did not show alpha-xylosidase activity. This narrower substrate range indicates a discrepancy with annotations from different databases and the possibility of specific substrate adaptations of halophilic glucosidases due to high salinity. To our knowledge, this is the first report on the characterization of an alpha-glucosidase from the halophilic Archaea, which could serve as a new model to gain insights into carbon metabolism in this understudied microbial group.

  7. Cerenkov counting and Cerenkov-scintillation counting with high refractive index organic liquids using a liquid scintillation counter

    Energy Technology Data Exchange (ETDEWEB)

    Wiebe, L I; Helus, F; Maier-Borst, W [Deutsches Krebsforschungszentrum, Heidelberg (Germany, F.R.). Inst. fuer Nuklearmedizin

    1978-06-01

    /sup 18/F and /sup 14/C radioactivity was measured in methyl salicylate (MS), a high refractive index hybrid Cherenkov-scintillation generating medium, using a liquid scintillation counter. At concentrations of up to 21.4%, in MS, dimethyl sulfoxide (DMSO) quenched /sup 14/C fluorescence, and with a 10-fold excess of DMSO over MS, /sup 18/F count rates were reduced below that for DMSO alone, probably as a result of concentration-independent self-quenching due to 'dark-complex' formation. DMSO in lower concentrations did not reduce the counting efficiency of /sup 18/F in MS. Nitrobenzene was a concentration-dependent quencher for both /sup 14/C and /sup 18/F in MS. Chlorobenzene (CB) and DMSO were both found to be weak Cherenkov generators with /sup 18/F. Counting efficiencies for /sup 18/F in MS, CB, and DMSO were 50.3, 7.8 and 4.3% respectively in the coincidence counting mode, and 58.1, 13.0 and 6.8% in the singles mode. /sup 14/C efficiencies were 14.4 and 22.3% for coincidence and singles respectively, and 15.3 and 42.0% using a modern counter designed for coincidence and single photon counting. The high /sup 14/C and /sup 18/F counting efficiency in MS are discussed with respect to excitation mechanism, on the basis of quench and channels ratios changes observed. It is proposed that MS functions as an efficient Cherenkov-scintillation generator for high-energy beta emitters such as /sup 18/F, and as a low-efficiency scintillator for weak beta emitting radionuclides such as /sup 14/C.

  8. Multinozzle emitter arrays for ultrahigh-throughput nanoelectrospray mass spectrometry

    Science.gov (United States)

    Wang, Daojing; Mao, Pan; Wang, Hung-Ta; Yang, Peidong

    2017-10-17

    The present invention provides for a structure comprising a plurality of emitters, wherein a first nozzle of a first emitter and a second nozzle of a second emitter emit in two directions that are not or essentially not in the same direction; wherein the walls of the nozzles and the emitters form a monolithic whole. The present invention also provides for a structure comprising an emitter with a sharpened end from which the emitter emits; wherein the emitters forms a monolithic whole. The present invention also provides for a fully integrated separation of proteins and small molecules on a silicon chip before the electrospray mass spectrometry analysis.

  9. Hydraulic performance evaluation of pressure compensating (pc) emitters and micro-tubing for drip irrigation system

    International Nuclear Information System (INIS)

    Mangrio, A.G.; Asif, M.; Jahangir, I.

    2013-01-01

    Drip irrigation system is necessary for those areas, where the water scarcity issues are present. The present study was conducted at the field station of Climate Change, Alternate Energy and Water Resources Institute (CAEWRI), National Agricultural Research Center (NARC), Islamabad, during 2013, regarding drip irrigation system. Drip irrigation system depends on uniform emitter application flow. All the emitters were tested and replicated thrice at pressure head (34 to 207Kpa) with an increment of 34 Kpa. The minimum and maximum discharges were 1.32 - 3.52, 3.36 - 5.42, and 43.22 - 100.99 Lph, with an average of 2.42, 4.63 and 73.66 Lph, for Bow Smith, RIS and Micro-tubing, respectively. It indicates that more than 90% of emission uniformity (EU) and uniformity coefficient (CU) for all Emitters, which shows excellent water application with least standard deviation, ranging 0.12 to 2.37, throughout the operating pressure heads in all emitters. An average coefficient of variation (CV) of all emitters were behaving less than 0.07, indicating an excellent class at all operating pressure heads between 34 to 207 Kpa. Moreover, the relationship of discharge and pressure of emitters indicates that discharge increased with the increase of pressure head. The Q-H curve plays key role in the selection of emitters. (author)

  10. Hybrid emitter all back contact solar cell

    Science.gov (United States)

    Loscutoff, Paul; Rim, Seung

    2016-04-12

    An all back contact solar cell has a hybrid emitter design. The solar cell has a thin dielectric layer formed on a backside surface of a single crystalline silicon substrate. One emitter of the solar cell is made of doped polycrystalline silicon that is formed on the thin dielectric layer. The other emitter of the solar cell is formed in the single crystalline silicon substrate and is made of doped single crystalline silicon. The solar cell includes contact holes that allow metal contacts to connect to corresponding emitters.

  11. Emittance measurements of the CLIO electron beam

    Science.gov (United States)

    Chaput, R.; Devanz, G.; Joly, P.; Kergosien, B.; Lesrel, J.

    1997-02-01

    We have designed a setup to measure the transverse emittance at the CLIO accelerator exit, based on the "3 gradients" method. The beam transverse size is measured simply by scanning it with a steering coil across a fixed jaw and recording the transmitted current, at various quadrupole strengths. A code then performs a complete calculation of the emittance using the transfer matrix of the quadrupole instead of the usual classical lens approximation. We have studied the influence of various parameters on the emittance: Magnetic field on the e-gun and the peak current. We have also improved a little the emittance by replacing a mismatched pipe between the buncher and accelerating section to avoid wake-field effects; The resulting improvements of the emittance have led to an increase in the FEL emitted power.

  12. THE ARECIBO LEGACY FAST ALFA SURVEY: THE {alpha}.40 H I SOURCE CATALOG, ITS CHARACTERISTICS AND THEIR IMPACT ON THE DERIVATION OF THE H I MASS FUNCTION

    Energy Technology Data Exchange (ETDEWEB)

    Haynes, Martha P.; Giovanelli, Riccardo; Martin, Ann M.; Adams, Elizabeth A. K.; Hallenbeck, Gregory; Huang Shan; Papastergis, Emmanouil, E-mail: haynes@astro.cornell.edu, E-mail: riccardo@astro.cornell.edu, E-mail: amartin@astro.cornell.edu, E-mail: betsey@astro.cornell.edu, E-mail: ghallenbeck@astro.cornell.edu, E-mail: shan@astro.cornell.edu [Center for Radiophysics and Space Research, Space Sciences Building, Cornell University, Ithaca, NY 14853 (United States); and others

    2011-11-15

    We present a current catalog of 21 cm H I line sources extracted from the Arecibo Legacy Fast Arecibo L-band Feed Array (ALFALFA) survey over {approx}2800 deg{sup 2} of sky: the {alpha}.40 catalog. Covering 40% of the final survey area, the {alpha}.40 catalog contains 15,855 sources in the regions 07{sup h}30{sup m} < R.A. < 16{sup h}30{sup m}, +04 Degree-Sign < decl. <+16 Degree-Sign , and +24 Degree-Sign < decl. <+28 Degree-Sign and 22{sup h} < R.A. < 03{sup h}, +14 Degree-Sign < decl. <+16 Degree-Sign , and +24 Degree-Sign < decl. < + 32 Degree-Sign . Of those, 15,041 are certainly extragalactic, yielding a source density of 5.3 galaxies per deg{sup 2}, a factor of 29 improvement over the catalog extracted from the H I Parkes All-Sky Survey. In addition to the source centroid positions, H I line flux densities, recessional velocities, and line widths, the catalog includes the coordinates of the most probable optical counterpart of each H I line detection, and a separate compilation provides a cross-match to identifications given in the photometric and spectroscopic catalogs associated with the Sloan Digital Sky Survey Data Release 7. Fewer than 2% of the extragalactic H I line sources cannot be identified with a feasible optical counterpart; some of those may be rare OH megamasers at 0.16 < z < 0.25. A detailed analysis is presented of the completeness, width-dependent sensitivity function and bias inherent of the {alpha}.40 catalog. The impact of survey selection, distance errors, current volume coverage, and local large-scale structure on the derivation of the H I mass function is assessed. While {alpha}.40 does not yet provide a completely representative sampling of cosmological volume, derivations of the H I mass function using future data releases from ALFALFA will further improve both statistical and systematic uncertainties.

  13. Design and development of multiple sample counting setup

    International Nuclear Information System (INIS)

    Rath, D.P.; Murali, S.; Babu, D.A.R.

    2010-01-01

    Full text: The analysis of active samples on regular basis for ambient air activity and floor contamination from radio chemical lab accounts for major chunk of the operational activity in Health Physicist's responsibility. The requirement for daily air sample analysis on immediate counting and delayed counting from various labs in addition to samples of smear swipe check of lab led to the urge for development of system that could cater multiple sample analysis in a time programmed manner on a single sample loading. A multiple alpha/beta counting system for counting was designed and fabricated. It has arrangements for loading 10 samples in slots in order, get counted in a time programmed manner with results displayed and records maintained in PC. The paper describes the design and development of multiple sample counting setup presently in use at the facility has resulted in reduction of man-hour consumption in counting and recording of the results

  14. 2-D emittance equation with acceleration and compression

    International Nuclear Information System (INIS)

    Hahn, K.D.; Smith, L.

    1988-10-01

    Since both acceleration and compression are required for an Inertial Fusion Driver, the understanding of their effect on the beam quality, emittance, is important. This report attempts to generalize the usual emittance formula for the drifting beam to include these effects. The derivation of the 2-D emittance equation is carried out and a comparison with the particle code results is given. The 2-D emittance at a given axial location is reasonable to consider for a long beam, particularly with velocity tilt; transverse emittance averaged over the entire bunch is not a useful quantity. 6 refs., 2 figs., 1 tab

  15. Effect of polonium alpha-radiation on aqueous solutions (the history of French and Russian studies)

    International Nuclear Information System (INIS)

    Vladimirova, M.V.

    1998-01-01

    Since Pierre and Marie Curie's discovery of polonium and radium the effect of their radiation on chemical systems was noted. This gave rise to a new science - radiation chemistry. Systematic studies of radiation effects go back to the mid-1940s. The effect of gamma and x radiation was studied most, while only M. Curie's laboratory in France was concerned with alpha emitting polonium and radon. M. Haissinsky, M. Lefort, P. Bonet-Marry, M. Anta pioneered this activity. Radon was soon abandoned in favour of polonium recovered from RaD. With its short half-life, polonium is an ideal emitter which at its low content by weight produces a highly intensive radiation. French scientists determined radiation yields of H 2 , O 2 , H 2 O 2 and that of water radiolytic decomposition, G[-H 2 O]. The latter was found to be equal to 3.5 molecule/100 eV and much less than that from gamma radiolysis (4.2 molecule/100 eV). It should be noted that the polonium recovered from RaD contained a variety of impurities influencing the yield of radiolysis products formed. From the outset of her study in 1957, the author of this paper used the purest polonium recovered from reactor-irradiated Bi-209. This made it possible to define the yields from alpha radiolysis of various aqueous solutions more exactly. Relying on the J. Pucheault hypothesis concerning the decomposition of molecular radiolysis products in heavy particle tracks, author's efforts were directed toward the quantification of initial radiolysis yields. Special experiments have shown that G[-H 2 O] is much the same from alpha and gamma radiolysis (around 4.2 molecule/100eV). The author had the good luck to discuss her results with Pr. M. Haissinsky from Laboratory Curie. (author)

  16. Analysis of radionuclide mixtures by {alpha}-{gamma} and {beta}-{gamma} coincidences using a simple device; Analyse de melanges de radionucleides par un dispositif simple de coincidences {alpha}-{gamma} et {beta}-{gamma}

    Energy Technology Data Exchange (ETDEWEB)

    Pottier, R; Berger, R [Commissariat a l' Energie Atomique, Centre d' Etudes Nucleaires de Fontenay-aux-Roses, 92 (France)

    1966-06-01

    A procedure is described for the qualitative and quantitative spectrographic analysis of radioactive sources containing two alpha-gamma emitters having the same alpha energy or two beta-gamma emitters having the same gamma energy. The main apparatus is a multichannel pulse-height analyzer including a coincidence circuit. The principle of the method, the synoptic scheme, the electronic device, the type of sources, and the precautions to be taken or the corrections to take into account are reported. The results obtained in solving the three following problems are discussed as examples of applications of the method: analysis of {sup 241}Am in alpha-gamma sources containing {sup 238}Pu; analysis of {sup 237}Np in beta-gamma sources containing {sup 239}Pu; and analysis of {sup 106}Ru-{sup 106}Rh in beta-gamma sources containing {sup 95}Zr-{sup 95}Nb. (authors) [French] Dans ce. rapport, on presente une methode d'analyse spectrographique qualitative et quantitative de sources radioactives contenant deux emetteurs alpha-gamma de meme energie alpha et deux emetteurs beta-gamma de meme energie gamma. L'organe principal est un analyseur d'amplitude a 400 canaux comprenant un circuit de coincidence. On decrit le principe de la methode, le schema synoptique, l'appareillage, le type des sources, les precautions a prendre ou les corrections a faire. On discute les resultats obtenus dans la solution des trois problemes suivants traites a titre d'application de la methode: 1. analyse d'americium 241 en presence de plutonium 238; 2. analyse de neptunium 237 en presence de plutonium 239; 3. analyse de ruthenium 106-rhodium 106 en presence de zirconium 95-niobium 95. (auteurs)

  17. Emittance growth in rf linacs

    International Nuclear Information System (INIS)

    Jameson, R.A.

    1979-01-01

    As the space-charge limit is approached, the current that can be accelerated in an rf linac and the output emittance that can be expected are discussed. The role of the envelope equations to estimate limits is outlined. The results of numerical experiments to explore general properties of emittance growth are given

  18. A quick method for estimation of long-lived alpha activity in work atmospheres

    International Nuclear Information System (INIS)

    Srivastava, G.K.; Ramakrishna Rao, A.; Balbudhe, A.Y.; Sarma, P.S.

    2003-01-01

    In an operating plant quick reporting of the status of long-lived alpha activity concentrations in the work atmosphere is required. This will help in taking any corrective control measures if required. Radon and thoron progeny concentrations prevalent in the general atmosphere predominantly interfere in measurement of long-lived alpha activity in air. The alpha counts due to radon and thoron progeny vary widely in many atmospheric conditions. Therefore, conventionally, 5 days delay is allowed for all interfering activity to decay completely and true alpha air activity is then estimated. An approach for quick assessment of long-lived alpha activity by eliminating interference due to radon and thoron progeny in air, is made here. Based on the study of the pattern of alpha count rate due to radon and thoron progeny in air, a method for estimation of long-lived alpha activity within 8 hours delay time is suggested in this paper. (author)

  19. Alpha spectrometry without chemistry

    International Nuclear Information System (INIS)

    Murray, A.S.; Heaton, B.

    1983-01-01

    A gridded cylindrical pulse ionization chamber is considered for the simultaneous analysis of natural alpha emitters. Solid sources of up to 0.3 g are deposited after wet grinding as a thin layer on 1.1 m 2 of aluminized plastic film, which acts as the cathode. No chemistry is involved, and thus there is little chance of nuclide fractionation. With a ''weightless'' source the resolution is about 55 keV; 110 keV has been easily achieved at 4.2 MeV with real sources. We conclude that significant information about isotope activities in the natural series is available with only a fraction of the work involved in conventional techniques. (author)

  20. Minimum emittance in TBA and MBA lattices

    Science.gov (United States)

    Xu, Gang; Peng, Yue-Mei

    2015-03-01

    For reaching a small emittance in a modern light source, triple bend achromats (TBA), theoretical minimum emittance (TME) and even multiple bend achromats (MBA) have been considered. This paper derived the necessary condition for achieving minimum emittance in TBA and MBA theoretically, where the bending angle of inner dipoles has a factor of 31/3 bigger than that of the outer dipoles. Here, we also calculated the conditions attaining the minimum emittance of TBA related to phase advance in some special cases with a pure mathematics method. These results may give some directions on lattice design.

  1. Minimum emittance in TBA and MBA lattices

    International Nuclear Information System (INIS)

    Xu Gang; Peng Yuemei

    2015-01-01

    For reaching a small emittance in a modern light source, triple bend achromats (TBA), theoretical minimum emittance (TME) and even multiple bend achromats (MBA) have been considered. This paper derived the necessary condition for achieving minimum emittance in TBA and MBA theoretically, where the bending angle of inner dipoles has a factor of 3 1/3 bigger than that of the outer dipoles. Here, we also calculated the conditions attaining the minimum emittance of TBA related to phase advance in some special cases with a pure mathematics method. These results may give some directions on lattice design. (authors)

  2. Bile acid metabolism in cirrhosis. VIII. Quantitative evaluation of bile acid synthesis from [7 beta-3H]7 alpha-hydroxycholesterol and [G-3H]26-hydroxycholesterol

    International Nuclear Information System (INIS)

    Goldman, M.; Vlahcevic, Z.R.; Schwartz, C.C.; Gustafsson, J.; Swell, L.

    1982-01-01

    In order to evaluate more definitively the observed aberrations in the synthesis of cholic and chenodeoxycholic acids in patients with advanced cirrhosis, two bile acid biosynthesis pathways were examined by determining the efficiency of conversion of [ 3 H]7 alpha-hydroxycholesterol and [ 3 H] 26-hydroxycholesterol to primary bile acids. Bile acid kinetics were determined by administration of [ 14 C]cholic and [ 14 C]chenodeoxycholic acids. Cholic acid synthesis in cirrhotic patients was markedly depressed (170 vs 927 μmoles per day)( while chenodeoxycholic acid synthesis was reduced to a much lesser degree (227 vs 550 μmoles per day). The administration of [ 3 H]7 alpha-hydroxycholesterol allowed for an evaluation of the major pathway of bile acid synthesis via the 7 alpha-hydroxylation of cholesterol. This compound was efficiently incorporated into primary bile acids by the two normal subjects (88 and 100%) and two cirrhotic patients (77 and 91%). However, the recovery of the label in cholic acid was slightly less in cirrhotic patients than in normal subjects. [ 3 H]26-hydroxycholesterol was administered to ascertain the contribution of the 26-hydroxylation pathway to bile acid synthesis. All study subjects showed poor conversion (9 to 22%) of this intermediate into bile acids. The results of this study suggest that a major block in the bile acid synthesis pathway in cirrhosis is at the level of 7 alpha-hydroxylation of cholesterol (impairment of 7 alpha-hydroxylase) and/or in the feedback triggering mechanism regulating bile acid synthesis. The data also suggest that the 26-hydroxylation pathway in normal subjects and patients with cirrhosis is a minor contributor to synthesis of the primary bile acids. Therefore, the relative sparing of chenodeoxycholic acid synthesis observed in cirrhotic patients is not due to preferential synthesis of this bile acid via the 26-hydroxylation pathway

  3. Design and synthesis of novel sulfonamide-containing bradykinin hB2 receptor antagonists. 1. Synthesis and SAR of alpha,alpha-dimethylglycine sulfonamides.

    Science.gov (United States)

    Fattori, Daniela; Rossi, Cristina; Fincham, Christopher I; Berettoni, Marco; Calvani, Federico; Catrambone, Fernando; Felicetti, Patrizia; Gensini, Martina; Terracciano, Rosa; Altamura, Maria; Bressan, Alessandro; Giuliani, Sandro; Maggi, Carlo A; Meini, Stefania; Valenti, Claudio; Quartara, Laura

    2006-06-15

    We recently published the extensive in vivo pharmacological characterization of MEN 16132 (J. Pharmacol. Exp. Ther. 2005, 616-623; Eur. J. Pharmacol. 2005, 528, 7), a member of the sulfonamide-containing human B(2) receptor (hB(2)R) antagonists. Here we report, in detail, how this family of compounds was designed, synthesized, and optimized to provide a group of products with subnanomolar affinity for the hB(2)R and high in vivo potency after topical administration to the respiratory tract. The series was designed on the basis of indications from the X-ray structures of the key structural motifs A and B present in known antagonists and is characterized by the presence of an alpha,alpha-dialkyl amino acid. The first lead (17) of the series was submitted to extensive chemical work to elucidate the structural requirements to increase hB(2) receptor affinity and antagonist potency in bioassays expressing the human B(2) receptor (hB(2)R). The following structural features were selected: a 2,4-dimethylquinoline moiety and a piperazine linker acylated with a basic amino acid. The representative lead compound 68 inhibited the specific binding of [(3)H]BK to hB(2)R with a pKi of 9.4 and antagonized the BK-induced inositolphosphate (IP) accumulation in recombinant cell systems expressing the hB(2)R with a pA(2) of 9.1. Moreover, compound 68 when administered (300 nmol/kg) intratracheally in the anesthetized guinea pig, was able to significantly inhibit BK-induced bronchoconstriction for up to 120 min after its administration, while having a lower and shorter lasting effect on hypotension.

  4. Barium depletion in hollow cathode emitters

    International Nuclear Information System (INIS)

    Polk, James E.; Mikellides, Ioannis G.; Katz, Ira; Capece, Angela M.

    2016-01-01

    Dispenser hollow cathodes rely on a consumable supply of Ba released by BaO-CaO-Al 2 O 3 source material in the pores of a tungsten matrix to maintain a low work function surface. The examination of cathode emitters from long duration tests shows deposits of tungsten at the downstream end that appear to block the flow of Ba from the interior. In addition, a numerical model of Ba transport in the cathode plasma indicates that the Ba partial pressure in the insert may exceed the equilibrium vapor pressure of the dominant Ba-producing reaction, and it was postulated previously that this would suppress Ba loss in the upstream part of the emitter. New measurements of the Ba depletion depth from a cathode insert operated for 8200 h reveal that Ba loss is confined to a narrow region near the downstream end, confirming this hypothesis. The Ba transport model was modified to predict the depletion depth with time. A comparison of the calculated and measured depletion depths gives excellent qualitative agreement, and quantitative agreement was obtained assuming an insert temperature 70 °C lower than measured beginning-of-life values

  5. Cancer from internal emitters

    International Nuclear Information System (INIS)

    Boecker, B.B.; Griffith, W.C. Jr.

    1995-01-01

    Irradiation from internal emitters, or internally deposited radionuclides, is an important component of radiation exposures encountered in the workplace, home, or general environment. Long-term studies of human populations exposed to various internal emitters by different routes of exposure are producing critical information for the protection of workers and members of the general public. The purpose of this report is to examine recent developments and discuss their potential importance for understanding lifetime cancer risks from internal emitters. The major populations of persons being studied for lifetime health effects from internally deposited radionuclides are well known: Lung cancer in underground miners who inhaled Rn progeny, liver cancer from persons injected with the Th-containing radiographic contrast medium Thorotrast, bone cancer from occupational or medical intakes of 226 Ra or medical injections of 224 Ra, and thyroid cancer from exposures to iodine radionuclides in the environment or for medical purposes

  6. Calibration of nuclides by gamma-gamma sum peak coincidence counting

    International Nuclear Information System (INIS)

    Guevara, E.A.

    1986-01-01

    The feasibility of extending sum peak coincidence counting to the direct calibration of gamma-ray emitters having particular decay schemes was investigated, also checkings of the measurement accuracy, by comparing with more precise beta-gamma coincidence counting have been performed. New theoretical studies and experiments were developed, demonstrating the reliability of the procedure. Uncertainties of less than one percent were obtained when certain radioactive sources were measured. The application of the procedure to 60 Co, 22 Na, 47 Ca and 148 Pm was studied. Theoretical bases of sum peak coincidence counting were set in order to extend it as an alternative method for absolute activity determination. In this respect, theoretical studies were performed for positive and negative beta decay, and electron capture, either accompanied or unaccompanied by coincident gamma rays. They include decay schemes containing up to three daughter nuclide excited levels, for different geometrical configurations. Equations are proposed for a possible generalization of the procedure. (M.E.L.) [es

  7. Production of positron emitters of metallic elements to study plant uptake and distribution

    International Nuclear Information System (INIS)

    Watanabe, S.; Ishioka, N.S.; Sekine, T.; Osa, A.; Koizumi, M.; Kiyomiya, S.; Nakanishi, H.; Mori, S.

    2001-01-01

    The metallic positron emitters 52 Mn, 52 Fe and 62 Zn, the elements of which are essential nutrients for plants as well as for animals, have been produced for a new tracer method in plant physiology. The tracer method utilizes the detection of annihilation γ-rays, like PET in nuclear medicine, to obtain two-dimensional images on a plant as well as to obtain radioactivity counts at specified points in a plant; this method allows us to observe the tracer movement in a living plant without touching the test plant. The previously reported methods of radiochemical separation of these metallic positron emitters from targets were partly modified from the view of their use in plant physiology. Radionuclidic impurities remaining in the final solutions were examined by γ-ray spectrometry, and their influences on the above-mentioned measurements are discussed. From the experiments on a barley plant, the speeds of 52 Mn 2+ ion and 52 Fe 3+ - mugineic-acid complex have been obtained for the first time to be 0.2 cm/min and 1.0 cm/min, respectively. (orig.)

  8. Measurement of concentrations of {gamma}-ray emitters induced in the concrete shield of the JAERI electron linac facility

    Energy Technology Data Exchange (ETDEWEB)

    Endo, Akira; Kawasaki, Katsuya; Kikuchi, Masamitsu [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Harada, Yasunori

    1997-07-01

    Measurement has been made to study distributions of {gamma}-ray emitters induced in the concrete shield of the JAERI electron linac facility. Core boring was carried out at seven positions to take samples from the concrete shield, and {gamma}-ray counting rates and {gamma}-ray spectra of these samples were measured with a NaI(Tl) detector and a Ge semiconductor detector, respectively. The following radionuclides were detected in the concrete samples: {sup 60}Co, {sup 134}Cs, {sup 152}Eu and {sup 154}Eu generated through thermal neutron capture reaction, and {sup 22}Na and {sup 54}Mn generated through nuclear reactions by bremsstrahlung and fast neutrons. The relation between the distributions of {gamma}-ray emitters, as a function of the depth of concrete, and the positions of core boring is discussed. (author)

  9. Performance comparison of scintillators for alpha particle detectors

    Energy Technology Data Exchange (ETDEWEB)

    Morishita, Yuki [Graduate School of Medicine, Nagoya University, 1-1-20 Daiko-Minami, Higashi-ku, Nagoya, Aichi 461-8673 (Japan); Japan Atomic Energy Agency, Muramatsu 4-33, Tokai-mura, Ibaraki 319-1194 (Japan); Yamamoto, Seiichi [Graduate School of Medicine, Nagoya University, 1-1-20 Daiko-Minami, Higashi-ku, Nagoya, Aichi 461-8673 (Japan); Izaki, Kenji [Japan Atomic Energy Agency, Muramatsu 4-33, Tokai-mura, Ibaraki 319-1194 (Japan); Kaneko, Junichi H.; Toui, Kohei; Tsubota, Youichi; Higuchi, Mikio [Graduate School of Engineering, Hokkaido University, Kita 13, Nishi 8, Kita-ku, Sapporo, Hokkaido 060-8628 (Japan)

    2014-11-11

    Scintillation detectors for alpha particles are often used in nuclear fuel facilities. Alpha particle detectors have also become important in the research field of radionuclide therapy using alpha emitters. ZnS(Ag) is the most often used scintillator for alpha particle detectors because its light output is high. However, the energy resolution of ZnS(Ag)-based scintillation detectors is poor because they are not transparent. A new ceramic sample, namely the cerium doped Gd{sub 2}Si{sub 2}O{sub 7} (GPS) scintillator, has been tested as alpha particle detector and its performances have been compared to that one of three different scintillating materials: ZnS(Ag), GAGG and a standard plastic scintillator. The different scintillating materials have been coupled to two different photodetectors, namely a photomultiplier tube (PMT) and a Silicon Photo-multiplier (Si-PM): the performances of each detection system have been compared. Promising results as far as the energy resolution performances (10% with PMT and 14% with Si-PM) have been obtained in the case of GPS and GAGG samples. Considering the quantum efficiencies of the photodetectors under test and their relation to the emission wavelength of the different scintillators, the best results were achieved coupling the GPS with the PMT and the GAGG with the Si-PM.

  10. Alpha-contaminated waste from reprocessing of nuclear fuel

    International Nuclear Information System (INIS)

    Sumner, W.

    1982-01-01

    The anticipated alpha-waste production rates from the Barnwell Nuclear Fuel Reprocessing plant is discussed. The estimated alpha-waste production rate from the 1500 metric ton/year plant is about 85,000 ft 3 /year at the 10 nCi/g limit. Most of this waste is estimated to come from the separation facility, and the major waste sources were cladding, which was 27%, and low-level contact-handled general process trash, which was estimated at 32% of the total. It was estimated that 45% of the waste was combustible and 72% of the waste was compactible. These characteristics could have a significant impact on the final volumes as disposed. Changing the alpha-waste limit from 10 nCi/g to 100 nCi/g was estimated to reduce the amount of alpha waste produced by about 20%. Again, the uncertainty in this value obviously has to be substantial. One has to recognize that these estimates were just that; they were not based on any operating experience. The total plutonium losses to waste, including the high-level waste, was estimated to be 1.5%. The cladding waste was estimated to be contaminated with alpha emitters to the extent of 10 4 to 10 5 nCi/g

  11. White organic light-emitting diodes from three emitter layers

    Energy Technology Data Exchange (ETDEWEB)

    Kim, M.S. [Department of Advanced Materials Science and Engineering, SungKyunKwan University, Suwon, Gyonggi-Do, 440-746 (Korea, Republic of); Lim, J.T. [Department of Advanced Materials Science and Engineering, SungKyunKwan University, Suwon, Gyonggi-Do, 440-746 (Korea, Republic of); Jeong, C.H. [Department of Advanced Materials Science and Engineering, SungKyunKwan University, Suwon, Gyonggi-Do, 440-746 (Korea, Republic of); Lee, J.H. [Department of Advanced Materials Science and Engineering, SungKyunKwan University, Suwon, Gyonggi-Do, 440-746 (Korea, Republic of); Yeom, G.Y. [Department of Advanced Materials Science and Engineering, SungKyunKwan University, Suwon, Gyonggi-Do, 440-746 (Korea, Republic of)]. E-mail: gyyeom@skku.edu

    2006-11-23

    Three-wavelength white organic light-emitting diodes (WOLEDs) were fabricated using two doped layers, which were obtained by separating the recombination zones into three emitter layers. A sky blue emission originated from the 4,4'-bis(2,2'-diphenylethen-1-yl)biphenyl (DPVBi) layer. A green emission originated from a tris(8-quinolinolato)aluminum (III) (Alq{sub 3}) host doped with a green fluorescent 10-(2-benzothiazolyl)-1,1,7,7-tetramethyl-2,3,6,7-tetrahydro-1H,5H,11H-[1] benz opyrano [6,7,8-ij]-quinolizin-11-one (C545T) dye. An orange emission was obtained from the N,N'-bis(1-naphthyl)-N,N'-diphenyl-1,1'-biphenyl-4,4'-diamine (NPB) host doped with a red fluorescent dye, 4-(dicyanomethylene)-2-tert-butyl-6-(1,1,7,7-tetramethyljulolidyl-9-enyl)-4 H-pyran (DCJTB). A white light resulted from the partial excitations of these three emitter layers by controlling the layer thickness and concentration of the fluorescent dyes in each emissive layer simultaneously. The electroluminescent spectrum of the device was not sensitive to the driving voltage of the device. The white light device showed a maximum luminance of approximately 53,000 cd/m{sup 2}. The external quantum and power efficiency at a luminance of approximately 100 cd/m{sup 2} were 2.62% and 3.04 lm/W, respectively.

  12. Development of Emittance Analysis Software for Ion Beam Characterization

    International Nuclear Information System (INIS)

    Padilla, M.J.; Liu, Yuan

    2007-01-01

    Transverse beam emittance is a crucial property of charged particle beams that describes their angular and spatial spread. It is a figure of merit frequently used to determine the quality of ion beams, the compatibility of an ion beam with a given beam transport system, and the ability to suppress neighboring isotopes at on-line mass separator facilities. Generally, a high-quality beam is characterized by a small emittance. In order to determine and improve the quality of ion beams used at the Holifield Radioactive Ion Beam Facility (HRIBF) for nuclear physics and nuclear astrophysics research, the emittances of the ion beams are measured at the off-line Ion Source Test Facilities. In this project, emittance analysis software was developed to perform various data processing tasks for noise reduction, to evaluate root-mean-square emittance, Twiss parameters, and area emittance of different beam fractions. The software also provides 2D and 3D graphical views of the emittance data, beam profiles, emittance contours, and RMS. Noise exclusion is essential for accurate determination of beam emittance values. A Self-Consistent, Unbiased Elliptical Exclusion (SCUBEEx) method is employed. Numerical data analysis techniques such as interpolation and nonlinear fitting are also incorporated into the software. The software will provide a simplified, fast tool for comprehensive emittance analysis. The main functions of the software package have been completed. In preliminary tests with experimental emittance data, the analysis results using the software were shown to be accurate

  13. DEVELOPMENT OF EMITTANCE ANALYSIS SOFTWARE FOR ION BEAM CHARACTERIZATION

    Energy Technology Data Exchange (ETDEWEB)

    Padilla, M. J.; Liu, Y.

    2007-01-01

    Transverse beam emittance is a crucial property of charged particle beams that describes their angular and spatial spread. It is a fi gure of merit frequently used to determine the quality of ion beams, the compatibility of an ion beam with a given beam transport system, and the ability to suppress neighboring isotopes at on-line mass separator facilities. Generally a high quality beam is characterized by a small emittance. In order to determine and improve the quality of ion beams used at the Holifi eld Radioactive Ion beam Facility (HRIBF) for nuclear physics and nuclear astrophysics research, the emittances of the ion beams are measured at the off-line Ion Source Test Facilities. In this project, emittance analysis software was developed to perform various data processing tasks for noise reduction, to evaluate root-mean-square emittance, Twiss parameters, and area emittance of different beam fractions. The software also provides 2D and 3D graphical views of the emittance data, beam profi les, emittance contours, and RMS. Noise exclusion is essential for accurate determination of beam emittance values. A Self-Consistent, Unbiased Elliptical Exclusion (SCUBEEx) method is employed. Numerical data analysis techniques such as interpolation and nonlinear fi tting are also incorporated into the software. The software will provide a simplifi ed, fast tool for comprehensive emittance analysis. The main functions of the software package have been completed. In preliminary tests with experimental emittance data, the analysis results using the software were shown to be accurate.

  14. Spent fuel UO2 matrix corrosion behaviour studies through alpha-doped UO2 pellets leaching

    International Nuclear Information System (INIS)

    Muzeau, B.; Jegou, C.; Broudic, V.

    2005-01-01

    Full text of publication follows: The option of direct disposal of spent nuclear fuel in a deep geological formation raises the need to investigate the long-term behaviour of the UO 2 matrix in aqueous media subjected to α-β-γ radiations. The β-γ emitters account for the most of the activity of spent fuel at the moment it is removed from the reactor, but diminish within a millennial time frame by over three orders of magnitude to less than the long-term activity. The latter persist over much longer time periods and must therefore be taken into account over geological disposal scale. In the present investigation the UO 2 matrix corrosion under alpha radiation is studied as a function of different parameters such as: the alpha activity, the carbonates and hydrogen concentrations,.. In order to study the effect of alpha radiolysis of water on the UO 2 matrix, 238/239 Pu doped UO 2 pellets (0.22 %wt. Pu total) were fabricated with different 238 Pu/ 239 Pu ratio to reproduce the alpha activity of a 47 GWd.t HMi -1 UOX spent fuel at different milestones in time (15, 50, 1500, 10000 and 40000 years). Undoped UO 2 pellets were also available as reference sample. Leaching experiments were conducted in deionized or carbonated water (NaHCO 3 1 mM), under Argon (O 2 2 30% gas mixture. Previous experiments conducted in deionized water under argon atmosphere, have shown a good correlation between alpha activity and uranium release for the 15-, 1500- and 40000-years alpha doped UO 2 batches. Besides, uranium release in the leachate is controlled either by the kinetics, or by the thermodynamics. Provided the solubility limit of uranium is not achieved, uranium concentration increases and is only limited by the kinetics, unless precipitation occurs and the uranium concentration remains constant over time. These controls are highly dependant on the solution chemistry (HCO 3 - , pH, Eh,..), the atmosphere (Ar, Ar/H 2 ,..), and the radiolysis strength. The experimental matrix

  15. Release of /sup 3/H-. cap alpha. -methyl-m-tyramine from rat striatum in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Dorris, R L [Baylor College of Dentistry, Dallas, Tex. (USA). Dept. of Pharmacology

    1976-01-01

    Release of /sup 3/H-d-..cap alpha..-methyl-m-tyramine (/sup 3/H-MMTA), a false dopaminergic transmitter from rat striatum was studied in vitro. After its initial uptake, /sup 3/H-MMTA was released by high K/sup +/ and by amphetamine. The release requirements were essentially the same as those known to exist for release of dopamine in vitro. These studies indicate that /sup 3/H-MMTA might serve as a useful tool with which to study dopamine release mechanisms in vitro.

  16. Highly reliable field electron emitters produced from reproducible damage-free carbon nanotube composite pastes with optimal inorganic fillers

    Science.gov (United States)

    Kim, Jae-Woo; Jeong, Jin-Woo; Kang, Jun-Tae; Choi, Sungyoul; Ahn, Seungjoon; Song, Yoon-Ho

    2014-02-01

    Highly reliable field electron emitters were developed using a formulation for reproducible damage-free carbon nanotube (CNT) composite pastes with optimal inorganic fillers and a ball-milling method. We carefully controlled the ball-milling sequence and time to avoid any damage to the CNTs, which incorporated fillers that were fully dispersed as paste constituents. The field electron emitters fabricated by printing the CNT pastes were found to exhibit almost perfect adhesion of the CNT emitters to the cathode, along with good uniformity and reproducibility. A high field enhancement factor of around 10 000 was achieved from the CNT field emitters developed. By selecting nano-sized metal alloys and oxides and using the same formulation sequence, we also developed reliable field emitters that could survive high-temperature post processing. These field emitters had high durability to post vacuum annealing at 950 °C, guaranteeing survival of the brazing process used in the sealing of field emission x-ray tubes. We evaluated the field emitters in a triode configuration in the harsh environment of a tiny vacuum-sealed vessel and observed very reliable operation for 30 h at a high current density of 350 mA cm-2. The CNT pastes and related field emitters that were developed could be usefully applied in reliable field emission devices.

  17. Spent fuel UO{sub 2} matrix corrosion behaviour studies through alpha-doped UO{sub 2} pellets leaching

    Energy Technology Data Exchange (ETDEWEB)

    Muzeau, B.; Jegou, C.; Broudic, V. [CEA-Valrho DEN/DTCD/SECM Laboratoire des Materiaux et Procedes Actifs BP 17171 F-30207 Bagnols-sur-Ceze cedex (France)

    2005-07-01

    Full text of publication follows: The option of direct disposal of spent nuclear fuel in a deep geological formation raises the need to investigate the long-term behaviour of the UO{sub 2} matrix in aqueous media subjected to {alpha}-{beta}-{gamma} radiations. The {beta}-{gamma} emitters account for the most of the activity of spent fuel at the moment it is removed from the reactor, but diminish within a millennial time frame by over three orders of magnitude to less than the long-term activity. The latter persist over much longer time periods and must therefore be taken into account over geological disposal scale. In the present investigation the UO{sub 2} matrix corrosion under alpha radiation is studied as a function of different parameters such as: the alpha activity, the carbonates and hydrogen concentrations,.. In order to study the effect of alpha radiolysis of water on the UO{sub 2} matrix, {sup 238/239}Pu doped UO{sub 2} pellets (0.22 %wt. Pu total) were fabricated with different {sup 238}Pu/{sup 239}Pu ratio to reproduce the alpha activity of a 47 GWd.t{sub HMi}{sup -1} UOX spent fuel at different milestones in time (15, 50, 1500, 10000 and 40000 years). Undoped UO{sub 2} pellets were also available as reference sample. Leaching experiments were conducted in deionized or carbonated water (NaHCO{sub 3} 1 mM), under Argon (O{sub 2} < 0.1 ppm), or Ar/H{sub 2} 30% gas mixture. Previous experiments conducted in deionized water under argon atmosphere, have shown a good correlation between alpha activity and uranium release for the 15-, 1500- and 40000-years alpha doped UO{sub 2} batches. Besides, uranium release in the leachate is controlled either by the kinetics, or by the thermodynamics. Provided the solubility limit of uranium is not achieved, uranium concentration increases and is only limited by the kinetics, unless precipitation occurs and the uranium concentration remains constant over time. These controls are highly dependant on the solution chemistry

  18. Measurement of precise particle distributions in emittance phase plane in the JHP LEBT

    International Nuclear Information System (INIS)

    Fujimura, S.; Ueno, A.

    1996-01-01

    A low energy beam transport (LEBT), in which any practical emittance growth due to the lens-aberration would not be caused, was developed for the Japanese Hadron Project (JHP). In the LEBT, we measured the precise distributions in the transverse emittance phase plane of the particles, which were extracted from the volume production H - ion source (VPIS) operated without cesium. The measured results showed good agreements with the simulation results using the initial particles at the exit of the VPIS generated with Ueno-Yokoya distribution (UY-dst), in which the particles are distributed uniformly in the real space (concerning with x and y) and distributed in Gaussian way concerning with x' and y'. We also detected the unexpectedly strong space-charge neutralization effect only with the residual H 2 gas with a pressure of 3.7 x 10 -6 Torr. In this condition, 93% of the beam intensity was neutralized with almost no beam loss due to electron stripping by collisions with H 2 gas. (author)

  19. Skeletal dosimetry models for alpha-particles for use in molecular radiotherapy

    Science.gov (United States)

    Watchman, Christopher J.

    Molecular radiotherapy is a cancer treatment methodology whereby a radionuclide is combined with a biologically active molecule to preferentially target cancer cells. Alpha-particle emitting radionuclides show significant potential for use in molecular radiotherapy due to the short range of the alpha-particles in tissue and their high rates of energy deposition. Current radiation dosimetry models used to assess alpha emitter dose in the skeleton were developed originally for occupational applications. In medical dosimetry, individual variability in uptake, translocation and other biological factors can result in poor correlation of clinical outcome with marrow dose estimates determined using existing skeletal models. Methods presented in this work were developed in response to the need for dosimetry models which account for these biological and patient-specific factors. Dosimetry models are presented for trabecular bone alpha particle dosimetry as well as a model for cortical bone dosimetry. These radiation transport models are the 3D chord-based infinite spongiosa transport model (3D-CBIST) and the chord-based infinite cortical transport model (CBICT), respectively. Absorbed fraction data for several skeletal tissues for several subjects are presented. Each modeling strategy accounts for biological parameters, such as bone marrow cellularity, not previously incorporated into alpha-particle skeletal dosimetry models used in radiation protection. Using these data a study investigating the variability in alpha-particle absorbed fractions in the human skeleton is also presented. Data is also offered relating skeletal tissue masses in individual bone sites for a range of ages. These data are necessary for dose calculations and have previously only been available as whole body tissue masses. A revised 3D-CBIST model is also presented which allows for changes in endosteum thickness to account for revised target cell location of tissues involved in the radiological

  20. A improved method for the analysis of alpha spectra

    International Nuclear Information System (INIS)

    Equillor, Hugo E.

    2004-01-01

    In this work we describe a methodology, developed in the last years, for the analysis of alpha emitters spectra, obtained with implanted ion detectors, that tend to solve some of the problems that shows this type of spectra. This is an improved methodology respect to that described in a previous publication. The method is based on the application of a mathematical function that allows to model the tail of an alpha peak, to evaluate the part of the peak that is not seen in the cases of partial superposition with another peak. Also, a calculation program that works in a semiautomatic way, with the possibility of interactive intervention of the analyst, has been developed simultaneously and is described in detail. (author)

  1. Quantum efficiency and thermal emittance of metal photocathodes

    Directory of Open Access Journals (Sweden)

    David H. Dowell

    2009-07-01

    Full Text Available Modern electron beams have demonstrated the brilliance needed to drive free electron lasers at x-ray wavelengths with major advances occurring since the invention of the photocathode gun and the realization of emittance compensation. These state-of-the-art electron beams are now becoming limited by the intrinsic thermal emittance of the cathode. In both dc and rf photocathode guns details of the cathode emission physics strongly influence the quantum efficiency and the thermal emittance. Therefore improving cathode performance is essential to increasing the brightness of beams. It is especially important to understand the fundamentals of cathode quantum efficiency and thermal emittance. This paper investigates the relationship between the quantum efficiency and the thermal emittance for metal cathodes using the Fermi-Dirac model for the electron distribution. We use a consistent theory to derive the quantum efficiency and thermal emittance, and compare our results to those of others.

  2. K- and M-type dwarf stars within 25 parsecs of the sun. I. The age-chromospheric activity relations from H-alpha equivalent widths

    Energy Technology Data Exchange (ETDEWEB)

    Eggen, O.J. (Observatorio Interamericano de Cerro Totolo, La Serena (Chile))

    1990-02-01

    The available equivalent-width measurements of H-alpha in dwarf K and M stars within 25 pc of the sun indicate that, as a chromospheric diagnostic, the H-alpha decay rate is about t exp 0.5. The decay rate of line emission in Mg II h and k (Ca II H and K) is about t exp 0.3. The decay rates are derived from observations of members of a few stellar superclusters and groups, for which the consistency of results argues strongly for the importance of more data. The only major inconsistency encountered is for the unique HR 1614 group which, in the age/chromospheric-activity progression, gives different results from Mg II h and k and from WH-alpha. 63 refs.

  3. Beam phase space and emittance

    International Nuclear Information System (INIS)

    Buon, J.

    1990-12-01

    The classical and elementary results for canonical phase space, the Liouville theorem and the beam emittance are reviewed. Then, the importance of phase portraits to obtain a geometrical description of motion is emphasized, with examples in accelerator physics. Finally, a statistical point of view is used to define beam emittance, to study its law of approximate conservation and to treat two particular examples

  4. Generalized superradiant assembly for nanophotonic thermal emitters

    Science.gov (United States)

    Mallawaarachchi, Sudaraka; Gunapala, Sarath D.; Stockman, Mark I.; Premaratne, Malin

    2018-03-01

    Superradiance explains the collective enhancement of emission, observed when nanophotonic emitters are arranged within subwavelength proximity and perfect symmetry. Thermal superradiant emitter assemblies with variable photon far-field coupling rates are known to be capable of outperforming their conventional, nonsuperradiant counterparts. However, due to the inability to account for assemblies comprising emitters with various materials and dimensional configurations, existing thermal superradiant models are inadequate and incongruent. In this paper, a generalized thermal superradiant assembly for nanophotonic emitters is developed from first principles. Spectral analysis shows that not only does the proposed model outperform existing models in power delivery, but also portrays unforeseen and startling characteristics during emission. These electromagnetically induced transparency like (EIT-like) and superscattering-like characteristics are reported here for a superradiant assembly, and the effects escalate as the emitters become increasingly disparate. The fact that the EIT-like characteristics are in close agreement with a recent experimental observation involving the superradiant decay of qubits strongly bolsters the validity of the proposed model.

  5. Internal emitter research and standard setting

    International Nuclear Information System (INIS)

    Stannard, J.N.

    1981-01-01

    The history of the use of data from internal emitter research in the derivation of safety standards is reviewed. At first, observed biological effects were correlated with body burdens or exposure levels. This direct approach is illustrated by detailed accounts of the cases of uranium and plutonium. In the 1950's, when it was decided to provide standards for over 200 isotopes, the direct approach was replaced by a system of calculations. This necessitated changes in internal emitter research programs to provide metabolic data, and the development of models such as Reference Man and the Lung and Gastrointestinal Tract models. The continuing contribution of internal emitter research to standard setting can be seen in the references quoted in the metabolic data section of the new ICRP report (ICRP Publication 30). Present trends suggest a possible return to the direct use of internal emitter effects data for obtaining risk estimates. (U.K.)

  6. Old and new versions of the alpha radiation theory of petroleum origin

    International Nuclear Information System (INIS)

    Paschoa, A.S.

    1981-03-01

    Some aspects of petroleum formation and the world distribution of fossil fuels deposits were recent clarified. However, the source of energy associated with petroleum genesis is still largely debatable. Evidence accumulated over the years allows to demonstrate the energetic feasibility of a modern version of the old alpha radiation theory of petroleum origin. This theory is reviewed and examined critically under new light to be reformulated by taking advantage of relevant interdisciplinary data mostly not available when the old alpha radiation theory was suggested, developed and then discredited. The geological ages accepted for the formation of most of the known petroleum reserves are within a range that makes long-lived natural alpha emitters a feasible energy source for at least part of the energy necessary for the formation of petroleum hydrocarbon. (author) [pt

  7. Comparative analysis of dose rates in bricks determined by neutron activation analysis, alpha counting and X-ray fluorescence analysis for the thermoluminescence fine grain dating method

    Science.gov (United States)

    Bártová, H.; Kučera, J.; Musílek, L.; Trojek, T.

    2014-11-01

    In order to evaluate the age from the equivalent dose and to obtain an optimized and efficient procedure for thermoluminescence (TL) dating, it is necessary to obtain the values of both the internal and the external dose rates from dated samples and from their environment. The measurements described and compared in this paper refer to bricks from historic buildings and a fine-grain dating method. The external doses are therefore negligible, if the samples are taken from a sufficient depth in the wall. However, both the alpha dose rate and the beta and gamma dose rates must be taken into account in the internal dose. The internal dose rate to fine-grain samples is caused by the concentrations of natural radionuclides 238U, 235U, 232Th and members of their decay chains, and by 40K concentrations. Various methods can be used for determining trace concentrations of these natural radionuclides and their contributions to the dose rate. The dose rate fraction from 238U and 232Th can be calculated, e.g., from the alpha count rate, or from the concentrations of 238U and 232Th, measured by neutron activation analysis (NAA). The dose rate fraction from 40K can be calculated from the concentration of potassium measured, e.g., by X-ray fluorescence analysis (XRF) or by NAA. Alpha counting and XRF are relatively simple and are accessible for an ordinary laboratory. NAA can be considered as a more accurate method, but it is more demanding regarding time and costs, since it needs a nuclear reactor as a neutron source. A comparison of these methods allows us to decide whether the time- and cost-saving simpler techniques introduce uncertainty that is still acceptable.

  8. Comprehensive analysis of collagen metabolism in vitro using [4(3H)]/[14C]proline dual-labeling and polyacrylamide gel electrophoresis

    International Nuclear Information System (INIS)

    Bateman, J.F.; Harley, V.; Chan, D.; Cole, W.G.

    1988-01-01

    A method to simultaneously quantify the production, secretion, and prolyl hydroxylation of individual types of collagen in cell culture samples has been developed. Collagens were biosynthetically labeled with a mixture of [ 14 C]proline and [4- 3 H]proline. The labeled collagens were isolated and their component alpha-chains were resolved by sodium dodecyl sulfate/polyacrylamide gel electrophoresis. Migration of the collagen alpha-chains was determined by fluorography, and radioactivity in excised bands was quantified by scintillation counting. [ 14 C]Proline labeling of collagen chains was used to determine the production and secretion of the different types of collagen. The ratios of the component alpha 1(I) and alpha 2(I) chains of type I collagen were also determined in this way. Prolyl hydroxylation of collagen alpha-chains was readily determined by measurement of their 3 H: 14 C ratios. Following 4-hydroxylation, 3 H was lost from the [4-3H]proline with alteration of this ratio. This dual-labeling method is suitable for the comprehensive analysis of collagen metabolism in multiple samples

  9. alpha-MSH and its receptors in regulation of tumor necrosis factor-alpha production by human monocyte/macrophages.

    Science.gov (United States)

    Taherzadeh, S; Sharma, S; Chhajlani, V; Gantz, I; Rajora, N; Demitri, M T; Kelly, L; Zhao, H; Ichiyama, T; Catania, A; Lipton, J M

    1999-05-01

    The hypothesis that macrophages contain an autocrine circuit based on melanocortin [ACTH and alpha-melanocyte-stimulating hormone (alpha-MSH)] peptides has major implications for neuroimmunomodulation research and inflammation therapy. To test this hypothesis, cells of the THP-1 human monocyte/macrophage line were stimulated with lipopolysaccharide (LPS) in the presence and absence of alpha-MSH. The inflammatory cytokine tumor necrosis factor (TNF)-alpha was inhibited in relation to alpha-MSH concentration. Similar inhibitory effects on TNF-alpha were observed with ACTH peptides that contain the alpha-MSH amino acid sequence and act on melanocortin receptors. Nuclease protection assays indicated that expression of the human melanocortin-1 receptor subtype (hMC-1R) occurs in THP-1 cells; Southern blots of RT-PCR product revealed that additional subtypes, hMC-3R and hMC-5R, also occur. Incubation of resting macrophages with antibody to hMC-1R increased TNF-alpha concentration; the antibody also markedly reduced the inhibitory influence of alpha-MSH on TNF-alpha in macrophages treated with LPS. These results in cells known to produce alpha-MSH at rest and to increase secretion of the peptide when challenged are consistent with an endogenous regulatory circuit based on melanocortin peptides and their receptors. Targeting of this neuroimmunomodulatory circuit in inflammatory diseases in which myelomonocytic cells are prominent should be beneficial.

  10. Solid-state single-photon emitters

    Science.gov (United States)

    Aharonovich, Igor; Englund, Dirk; Toth, Milos

    2016-10-01

    Single-photon emitters play an important role in many leading quantum technologies. There is still no 'ideal' on-demand single-photon emitter, but a plethora of promising material systems have been developed, and several have transitioned from proof-of-concept to engineering efforts with steadily improving performance. Here, we review recent progress in the race towards true single-photon emitters required for a range of quantum information processing applications. We focus on solid-state systems including quantum dots, defects in solids, two-dimensional hosts and carbon nanotubes, as these are well positioned to benefit from recent breakthroughs in nanofabrication and materials growth techniques. We consider the main challenges and key advantages of each platform, with a focus on scalable on-chip integration and fabrication of identical sources on photonic circuits.

  11. A low emittance configuration for spear

    International Nuclear Information System (INIS)

    Blumberg, L.N.; Cerino, J.; Harris, J.; Hettel, R.; Hofmann, A.; Liu, R.Z.; Stego, R.; Wiedemann, H.; Winick, H.

    1985-01-01

    The quality of synchrotron radiation beams from SPEAR, in particular the brilliance of undulator radiation, can be improved significantly by reducing the emittance of the stored electron beam. A reduction of the horizontal emittance by a factor of 3.5 to a value of 130 nanometer-radians (nm-r) at 3 GeV has been achieved by using stronger focussing, mainly in the horizontal plane. The low emittance configuration also reduces the dispersion and vertical beta functions in the straight sections, making them more suitable for wigglers. The higher betatron tunes lead to a larger phase advance between the two kickers, which has to be corrected during injection by shunting current from some quadrupoles. The configuration was optimized within SPEAR hardware limitations and tested for dynamic aperture with the tracking program PATRICIA. After implementation of this scheme, beam was successfully injected and accumulated. The measured emittance of the stored beam was in agreement with calculations. Presently the configuration is being made operational

  12. Emittance growth rates for displaced beams

    International Nuclear Information System (INIS)

    Anderson, O.A.

    1993-05-01

    Emittance growth rates have been previously analyzed for nonuniform beams in linear channels and for initially uniform mismatched beams in nonlinear channels. These studies were for centered beams. Additional emittance growth can arise in cases where the beam is initially displaced. The purpose of this study is to obtain growth rates for displaced beams. This work differs from studies involving random displacement of electrodes. Our analysis assumes instead that the focusing system is perfectly aligned but that the beam is initially displaced with respect to the equilibrium axis. If the focusing force is slightly nonlinear, we find a gradual transfer of the potential energy of beam displacement into kinetic energy associated with emittance growth. We present explicit results for the emittance growth distance as a function of the nonlinearity of the channel. These results will have practical importance for designers of accelerators and transport systems when setting realistic tolerances for initial beam alignment. These tolerances will depend on the nonlinearity and the length of the system

  13. Emittance variations in current-amplifying ion induction linacs

    International Nuclear Information System (INIS)

    Fessenden, T.J.

    1991-01-01

    Since 1985 the Heavy Ion Fusion Accelerator Research program at the Lawrence Berkeley Laboratory has been studying current amplification and emittance variations in MBE-4, a four-cesium-beam induction linac. This experiment models much of the accelerator physics of the electrostatically focused section of a fusion driver. Four space-charge dominated Cs + beams, initially about one meter in length at currents of 5-10 mA, are focused by electrostatic quadrupoles and accelerated in parallel from approximately 200 keV up to one MeV by 24 accelerating gaps. Final currents of 20-40 mA per beam are typical. Recent experiments with extremely low emittance beams (var-epsilon n =0.03 mm-mRad) have investigated variations of transverse and longitudinal normalized emittance for drifting and accelerating beams. These very strongly tune-depressed beams (σ 0 =72 degree, σ∼6 degree) are difficult to match to the accelerator so as to avoid emittance growth during acceleration. During transport strong emittance fluctuations are observed in good qualitative agreement with simulations. Warmer beams with less tune depression exhibit little to no emittance growth, show smaller emittance fluctuations, and are much easier to match. A summary of findings from the MBE-4 studies is presented

  14. Emittance variations in current-amplifying ion induction linacs

    International Nuclear Information System (INIS)

    Fessenden, T.J.

    1991-04-01

    Since 1985 the Heavy Ion Fusion Accelerator Research program at the Lawrence Berkeley Laboratory has been studying current amplification and emittance variations in MBE-4, a four-cesium-beam induction linac. This experiment models much of the accelerator physics of the electrostatically focused section of a fusion driver. Four space-charge dominated Cs + beams, initially about one meter in length at currents of 5--10 mA, are focused by electrostatic quadrupoles and accelerated in parallel from approximately 200 keV up to one MeV by 24 accelerating gaps. Final currents of 20--40 mA per beam are typical. Recent experiments with extremely low emittance beams (ε n = 0.03 mm-mRad) have investigated variations of transverse and longitudinal normalized emittance for drifting and accelerating beams. These very strongly tune-depressed beams (σ o = 72 degrees, σ∼6 degree) are difficult to match the accelerator so as to avoid emittance growth during acceleration. During transport strong emittance fluctuations are observed in good qualitative agreement with simulations. Warmer beams with less tune depression exhibit little to no emittance growth, show smaller emittance fluctuations, and are much easier to match. A summary of findings from the MBE-4 studies is presented. 12 refs., 8 figs

  15. Optimum Condition for Plutonium Electrodeposition Process in Radiochemistry and Environment Laboratory, Nuclear Malaysia

    International Nuclear Information System (INIS)

    Yii, Mei-Wo; Abdullah Siddiqi Ismail

    2014-01-01

    Determination of alpha emitting plutonium radionuclides such as Pu-238, Pu-239 and Pu-240 concentrations inside a sample require lots of radiochemistry purification process to separate them from other interfering alpha emitters. These pure isotopes are then been electrodeposited onto a stainless steel disc and quantified using alpha spectrometry counter. In Radiochemistry and Environment Laboratory (RAS), Nuclear Malaysia, the quantification is done by comparing these isotopes with the recovery of known amount plutonium tracer, Pu-242, that been added into the sample prior analysis. This study been conducted to find the optimum conditions for the electrolysis process used at RAS. Four variable parameters that may interfere the percentage recovery of tracer hence the current, cathode to anode distance, pH and electrolysis duration had been identify and studied. Study was carry out using Pu-242 standard solution and the deposition disc was counted using Zinc Sulphite (silver) counter. Studies outcome suggested that the optimum conditions to reduce plutonium ion happens at 1-1.1 ampere of current, 3-5 mm of electrodes distance, pH 2.2-2.5 and a minimal electrolysis duration of 2 hours. (author)

  16. Screening alpha-glucosidase and alpha-amylase inhibitors from natural compounds by molecular docking in silico.

    Science.gov (United States)

    Jhong, Chien-Hung; Riyaphan, Jirawat; Lin, Shih-Hung; Chia, Yi-Chen; Weng, Ching-Feng

    2015-01-01

    The alpha-glucosidase inhibitor is a common oral anti-diabetic drug used for controlling carbohydrates normally converted into simple sugars and absorbed by the intestines. However, some adverse clinical effects have been observed. The present study seeks an alternative drug that can regulate the hyperglycemia by down-regulating alpha-glucosidase and alpha-amylase activity by molecular docking approach to screen the hyperglycemia antagonist against alpha-glucosidase and alpha-amylase activities from the 47 natural compounds. The docking data showed that Curcumin, 16-hydroxy-cleroda-3,13-dine-16,15-olide (16-H), Docosanol, Tetracosanol, Antroquinonol, Berberine, Catechin, Quercetin, Actinodaphnine, and Rutin from 47 natural compounds had binding ability towards alpha-amylase and alpha-glucosidase as well. Curcumin had a better biding ability of alpha-amylase than the other natural compounds. Analyzed alpha-glucosidase activity reveals natural compound inhibitors (below 0.5 mM) are Curcumin, Actinodaphnine, 16-H, Quercetin, Berberine, and Catechin when compared to the commercial drug Acarbose (3 mM). A natural compound with alpha-amylase inhibitors (below 0.5 mM) includes Curcumin, Berberine, Docosanol, 16-H, Actinodaphnine/Tetracosanol, Catechin, and Quercetin when compared to Acarbose (1 mM). When taken together, the implication is that molecular docking is a fast and effective way to screen alpha-glucosidase and alpha-amylase inhibitors as lead compounds of natural sources isolated from medicinal plants. © 2015 International Union of Biochemistry and Molecular Biology.

  17. Gamma flux responsive self-powered detector with a tubular emitter

    International Nuclear Information System (INIS)

    Goldstein, N.P.; Todt, W.H.

    1982-01-01

    A gamma-sensitive flux detector comprises tubular emitter, an insulating core within the emitter and an insulating layer about the emitter, and a tubular conductive collector electrode about the insulating layer. The emitter material may be platinum, lead, bismuth, tantalum, tungsten; platinum preferred

  18. Methodology for estimation of 32P in bioassay samples by Cerenkov counting

    International Nuclear Information System (INIS)

    Wankhede, Sonal; Sawant, Pramilla D.; Yadav, R.K.B.; Rao, D.D.

    2016-01-01

    Radioactive phosphorus ( 32 P) as phosphate is used to effectively reduce bone pain in terminal cancer patients. Several hospitals in India carry out this palliative care procedure on a regular basis. Thus, production as well as synthesis of 32 P compounds has increased over the years to meet this requirement. Monitoring of radiation workers handling 32 P compounds is important for further strengthening of radiological protection program at processing facility. 32 P being a pure beta emitter (β max = 1.71 MeV, t 1/2 = 14.3 d), bioassay is the preferred individual monitoring technique. Method standardized at Bioassay Lab, Trombay, includes estimation of 32 P in urine by co-precipitation with ammonium phosphomolybdate (AMP) followed by gross beta counting. In the present study, feasibility of Cerenkov counting for detection of 32 P in bioassay samples was explored and the results obtained were compared with the gross beta counting technique

  19. Emittance Growth in the NLCTA First Chicane

    International Nuclear Information System (INIS)

    Sun, Yipeng

    2011-01-01

    In this paper, the emittance growth in the NLCTA (Next Linear Collider Test Accelerator) first chicane region is evaluated by simulation studies. It is demonstrated that the higher order fields of the chicane dipole magnet and the dipole corrector magnet (which is attached on the quadrupoles) are the main contributions for the emittance growth, especially for the case with a large initial emittance (γε 0 = 5 (micro)m for instance). These simulation results agree with the experimental observations.

  20. A combined emitter threat assessment method based on ICW-RCM

    Science.gov (United States)

    Zhang, Ying; Wang, Hongwei; Guo, Xiaotao; Wang, Yubing

    2017-08-01

    Considering that the tradition al emitter threat assessment methods are difficult to intuitively reflect the degree of target threaten and the deficiency of real-time and complexity, on the basis of radar chart method(RCM), an algorithm of emitter combined threat assessment based on ICW-RCM (improved combination weighting method, ICW) is proposed. The coarse sorting is integrated with fine sorting in emitter combined threat assessment, sequencing the emitter threat level roughly accordance to radar operation mode, and reducing task priority of the low-threat emitter; On the basis of ICW-RCM, sequencing the same radar operation mode emitter roughly, finally, obtain the results of emitter threat assessment through coarse and fine sorting. Simulation analyses show the correctness and effectiveness of this algorithm. Comparing with classical method of emitter threat assessment based on CW-RCM, the algorithm is visual in image and can work quickly with lower complexity.

  1. Recent developments for field monitoring of alpha-emitting contaminants in the environment

    International Nuclear Information System (INIS)

    Ahlquist, A.J.; Umbarger, C.J.; Stoker, A.K.

    1978-01-01

    The Los Alamos Scientific Laboratory has adapted two field methods to assess rapidly locations and concentrations of alpha-emitting contaminants in soil. (1) A ZnS scintillator is used for gross-alpha measurements on soil samples. Sample preparation and the calibration and detection limits of the system are discussed, and results of gross-alpha analysis are compared with results of a 239 Pu radiochemistry analysis. (2) A Phoswich detector is used as a field survey instrument because it can detect lower levels of radioactivity than the FIDLER probe. The electronics are carried in a truck and the probe is connected by an umbilical cord. The system electronics are calibrated with an energy window of 12-40 keV which allows detection of Pu, Am, Th (using daughter L X-rays of the alpha-emitters) and 137 Cs (using its daughter 32 keV X-rays). The bremsstrahlung from 90 Sr can also be detected. (author)

  2. Intraoperative detection of 18F-FDG-avid tissue sites using the increased probe counting efficiency of the K-alpha probe design and variance-based statistical analysis with the three-sigma criteria

    International Nuclear Information System (INIS)

    Povoski, Stephen P; Chapman, Gregg J; Murrey, Douglas A; Lee, Robert; Martin, Edward W; Hall, Nathan C

    2013-01-01

    Intraoperative detection of 18 F-FDG-avid tissue sites during 18 F-FDG-directed surgery can be very challenging when utilizing gamma detection probes that rely on a fixed target-to-background (T/B) ratio (ratiometric threshold) for determination of probe positivity. The purpose of our study was to evaluate the counting efficiency and the success rate of in situ intraoperative detection of 18 F-FDG-avid tissue sites (using the three-sigma statistical threshold criteria method and the ratiometric threshold criteria method) for three different gamma detection probe systems. Of 58 patients undergoing 18 F-FDG-directed surgery for known or suspected malignancy using gamma detection probes, we identified nine 18 F-FDG-avid tissue sites (from amongst seven patients) that were seen on same-day preoperative diagnostic PET/CT imaging, and for which each 18 F-FDG-avid tissue site underwent attempted in situ intraoperative detection concurrently using three gamma detection probe systems (K-alpha probe, and two commercially-available PET-probe systems), and then were subsequently surgical excised. The mean relative probe counting efficiency ratio was 6.9 (± 4.4, range 2.2–15.4) for the K-alpha probe, as compared to 1.5 (± 0.3, range 1.0–2.1) and 1.0 (± 0, range 1.0–1.0), respectively, for two commercially-available PET-probe systems (P < 0.001). Successful in situ intraoperative detection of 18 F-FDG-avid tissue sites was more frequently accomplished with each of the three gamma detection probes tested by using the three-sigma statistical threshold criteria method than by using the ratiometric threshold criteria method, specifically with the three-sigma statistical threshold criteria method being significantly better than the ratiometric threshold criteria method for determining probe positivity for the K-alpha probe (P = 0.05). Our results suggest that the improved probe counting efficiency of the K-alpha probe design used in conjunction with the three

  3. The determination of the optimum counting conditions for a ZnS(Ag) scintillation detector

    International Nuclear Information System (INIS)

    Djurasevic, M.M.; Kandic, A.B.; Novkovic, D.N; Vukanac, I.S. . E-mail address of corresponding author: mirad@vin.bg.ac.yu; Djurasevic, M.M.)

    2005-01-01

    The methods that use scintillation counting with ZnS(Ag) scintillation detector are widely used for gross alpha activity determination. The common criteria for the selection of optimum counting condition for a ZnS(Ag) scintillation detector do not consider simultaneously operating voltage and discrimination level variation. In presented method a relationship between voltage and discrimination level is derived for counting efficiency. (author)

  4. An alpha particle measurement system using an energetic neutral helium beam in ITER (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Sasao, M.; Tanaka, N.; Terai, K.; Kaneko, O. [Graduate school of Engineering, Tohoku University, Sendai 980-8579 (Japan); Kisaki, M.; Kobuchi, T.; Tsumori, K.; Okamoto, A.; Kitajima, S. [National Institute for Fusion Science, Toki, Gifu 509-5292 (Japan); Shinto, K. [IFMIF R and D Center, Japan Atomic Energy Agency, Rokkasho, Aomori 039-3212 (Japan); Wada, M. [Graduate School of Engineering, Doshisha University, Kyotanabe, Kyoto 610-0321 (Japan)

    2012-02-15

    An energetic helium neutral beam is involved in the beam neutralization measurement system of alpha particles confined in a DT fusion plasma. A full size strong-focusing He{sup +} ion source (2 A, the beam radius of 11.3 mm, the beam energy less than 20 keV). Present strong-focusing He{sup +} ion source shows an emittance diagram separated for each beamlet of multiple apertures without phase space mixing, despite the space charge of a beamlet is asymmetric and the beam flow is non-laminar. The emittance of beamlets in the peripheral region was larger than that of center. The heat load to the plasma electrode was studied to estimate the duty factor for the ITER application.

  5. Synthesis and evaluation of phytotoxic activity of {alpha}-Santonin derivatives; Sintese e avaliacao da atividade fitotoxica de derivados da {alpha}-Santonina

    Energy Technology Data Exchange (ETDEWEB)

    Alvarenga, Elson S.; Barbosa, Luiz C.A.; Saliba, William A.; Arantes, Francisco F.P.; Demuner, Antonio J. [Universidade Federal de Vicosa (UFV), MG (Brazil). Dept. de Quimica]. E-mail: elson@ufv.br; Silva, Antonio A. [Universidade Federal de Vicosa (UFV), MG (Brazil). Dept. de Fitotecnia

    2009-07-01

    Mixtures of {alpha}-Santonin and various solvents were irradiated by either high or low pressure mercury lamps. The photochemical reactions afforded lumisantonin (11) (76% in acetonitrile), (3 S,3a S,9{beta}S)-3,6,6-trimethyl-3,3a,4,5-tetrahydronafto[1,2-b]furan-2,7({eta}6,9{beta}{eta}) dione (12) (100% in acetonitrile), 10{alpha}-acetoxy-3-oxo-1,7{alpha}H{eta},6,11{alpha}a{eta}-guaia-4-en-6,12-oli= de (8) (26% in acetic acid), 10{alpha}-hydroxy-3-oxo-1,7{alpha}a{eta},6,11{alpha}{eta}-guaia-4-en-6,12-olid= e (10) (32%) and (E)-3-((3 S,3a S,7{alpha}S)-3-methyl-2-oxo-6-(propan-2-ylidene)hexahydrobenzofuran- 7 - (7{alpha}{eta})-ylidene)propanoic acid (9) (44%) (in water/ acetic acid 1:1, v/v). Lactone 12 was also prepared by irradiation of lumisantonin in diethyl ether. Lactones 8 and 10 were converted, respectively, into the 10 {alpha}-acetoxy-3{alpha}-hydroxy-1,7{alpha}H,6,11{alpha}H-guaia-4-en-6,12-olid= e (13) (87%) and 3a,10a-dihydroxy-1,7{alpha}H,6,11{alpha}H-guaia-4-en-6,12-olide (14) (75%) by sodium borohydride reduction. The effects of the compounds on the development of radicle of Sorghum bicolor and Cucumis sativus were evaluated. (author)

  6. Calculation of the detection efficiency in liquid scintillators. I.- Single negatrons emitters; Calculo de la eficiencia de deteccion en liquidos centelleadores. I. Nucleidos que se desintegran por emision simple de negatrones

    Energy Technology Data Exchange (ETDEWEB)

    Grau Malonda, A.; Garcia-torano, E.

    1981-07-01

    Counting efficiency for 62 single beta emitters has been computed from the beta energy distribution, the figure of merit and the ionization quenching. Efficiency v.s. figure of merit is plotted and tabulated. (Author) 16 refs.

  7. Application of neutron multiplicity counting to waste assay

    Energy Technology Data Exchange (ETDEWEB)

    Pickrell, M.M.; Ensslin, N. [Los Alamos National Lab., NM (United States); Sharpe, T.J. [North Carolina State Univ., Raleigh, NC (United States)

    1997-11-01

    This paper describes the use of a new figure of merit code that calculates both bias and precision for coincidence and multiplicity counting, and determines the optimum regions for each in waste assay applications. A {open_quotes}tunable multiplicity{close_quotes} approach is developed that uses a combination of coincidence and multiplicity counting to minimize the total assay error. An example is shown where multiplicity analysis is used to solve for mass, alpha, and multiplication and tunable multiplicity is shown to work well. The approach provides a method for selecting coincidence, multiplicity, or tunable multiplicity counting to give the best assay with the lowest total error over a broad spectrum of assay conditions. 9 refs., 6 figs.

  8. The TRIUMF compact DC H-/D- ion source

    International Nuclear Information System (INIS)

    Jayamanna, K.; McDonald, M.; Yuan, D.H.; Schmor, P.W.

    1990-06-01

    A compact dc H - /D - ion source using multicusp magnetic plasma confinement, has been experimentally studied and optimized on the TRIUMF ion source test stand. The plasma parameters have been obtained with rapid computer controlled Langmuir probe scans. The extraction electrode configuration, originally tailored to the TR30 cyclotron requirements, has been further developed. With a 12 mm diameter extraction hole this source now provides 9 mA within a normalized emittance of 0.44 π mm-mrad and can be easily modified for lower currents of smaller emittance (1 mA H - current with normalized emittance 0.12π.mm-mrad or 7 mA H - current with normalized emittance 0.34π.mm-mrad). The source has proven to have low maintenance, high reliability and long filament lifetime. This paper emphasizes basic plasma parameters which determine the efficiency of H - /D - production. Some experimental results obtained from several versions of the extraction system are also described. (Author) 6 refs., 8 figs

  9. 210Po in Nevada groundwater and its relation to gross alpha radioactivity

    Science.gov (United States)

    Seiler, R.L.

    2011-01-01

    Polonium-210 (210Po) is a highly toxic alpha emitter that is rarely found in groundwater at activities exceeding 1 pCi/L. 210Po activities in 63 domestic and public-supply wells in Lahontan Valley in Churchill County in northern Nevada, United States, ranged from 0.01 ± 0.005 to 178 ± 16 pCi/L with a median activity of 2.88 pCi/L. Wells with high 210Po activities had low dissolved oxygen concentrations (less than 0.1 mg/L) and commonly had pH greater than 9. Lead-210 activities are low and aqueous 210Po is unsupported by 210Pb, indicating that the 210Po is mobilized from aquifer sediments. The only significant contributors to alpha particle activity in Lahontan Valley groundwater are 234/238U, 222Rn, and 210Po. Radon-222 activities were below 1000 pCi/L and were uncorrelated with 210Po activity. The only applicable drinking water standard for 210Po in the United States is the adjusted gross alpha radioactivity (GAR) standard of 15 pCi/L. 210Po was not volatile in a Nevada well, but volatile 210Po has been reported in a Florida well. Additional information on the volatility of 210Po is needed because GAR is an inappropriate method to screen for volatile radionuclides. About 25% of the samples had 210Po activities that exceed the level associated with a lifetime total cancer risk of 1× 10−4 (1.1 pCi/L) without exceeding the GAR standard. In cases where the 72-h GAR exceeds the uranium activity by more than 5 to 10 pCi/L, an analysis to rule out the presence of 210Po may be justified to protect human health even though the maximum contaminant level for adjusted GAR is not exceeded.

  10. Measurements of Thermal Emittance for Cesium Telluride Photocathodes at PITZ

    CERN Document Server

    Miltchev, V; Grabosch, H J; Han, J H; Krasilnikov, M; Oppelt, A; Petrosian, B; Staykov, L; Stephan, F

    2005-01-01

    The thermal emittance determines the lower emittance limit and its measurement is of high importance to understand the ultimate injector performance. In this contribution we present results of thermal emittance measurements under rf operation conditions for various Cs2Te cathodes and different accelerating gradients. Measurements of thermal emittance scaling with the cathode laser spot size are presented and analysed. The significance of the Schottky effect in the emittance formation process is discussed.

  11. Computed neutron coincidence counting applied to passive waste assay

    Energy Technology Data Exchange (ETDEWEB)

    Bruggeman, M.; Baeten, P.; De Boeck, W.; Carchon, R. [Nuclear Research Centre, Mol (Belgium)

    1997-11-01

    Neutron coincidence counting applied for the passive assay of fissile material is generally realised with dedicated electronic circuits. This paper presents a software based neutron coincidence counting method with data acquisition via a commercial PC-based Time Interval Analyser (TIA). The TIA is used to measure and record all time intervals between successive pulses in the pulse train up to count-rates of 2 Mpulses/s. Software modules are then used to compute the coincidence count-rates and multiplicity related data. This computed neutron coincidence counting (CNCC) offers full access to all the time information contained in the pulse train. This paper will mainly concentrate on the application and advantages of CNCC for the non-destructive assay of waste. An advanced multiplicity selective Rossi-alpha method is presented and its implementation via CNCC demonstrated. 13 refs., 4 figs., 2 tabs.

  12. Computed neutron coincidence counting applied to passive waste assay

    International Nuclear Information System (INIS)

    Bruggeman, M.; Baeten, P.; De Boeck, W.; Carchon, R.

    1997-01-01

    Neutron coincidence counting applied for the passive assay of fissile material is generally realised with dedicated electronic circuits. This paper presents a software based neutron coincidence counting method with data acquisition via a commercial PC-based Time Interval Analyser (TIA). The TIA is used to measure and record all time intervals between successive pulses in the pulse train up to count-rates of 2 Mpulses/s. Software modules are then used to compute the coincidence count-rates and multiplicity related data. This computed neutron coincidence counting (CNCC) offers full access to all the time information contained in the pulse train. This paper will mainly concentrate on the application and advantages of CNCC for the non-destructive assay of waste. An advanced multiplicity selective Rossi-alpha method is presented and its implementation via CNCC demonstrated. 13 refs., 4 figs., 2 tabs

  13. Low level alpha activity measurements with pulse shape discrimination

    International Nuclear Information System (INIS)

    Satoh, Kaneaki; Higuchi, Hideo; Kitamura, Kiyoshi; Noguchi, Masayasu.

    1984-01-01

    Liquid scintillation counting of α rays with pulse shape discrimination was applied to the analysis of 226 Ra and 239+240 Pu in environmental samples and of α-emitters in/on a filter paper. The instrument used in this study was either a specially designed detector or a commercial liquid scintillation counter with an automatic sample changer, both of which were connected to the pulse shape discrimination circuit. The background counting rate in α energy region of 5-7 MeV was 0.01 or 0.04 cpm/MeV, respectively. The figure of merit indicating the resolving power for α- and β-particles in time spectrum was found to be 5.7 for the commercial liquid scintillation counter. (author)

  14. Electron emitter pulsed-type cylindrical IEC

    International Nuclear Information System (INIS)

    Miley, G.H.; Gu, Y.; Stubbers, R.; Zich, R.; Anderl, R.; Hartwell, J.

    1997-01-01

    A cylindrical version of the single grid Inertial Electrostatic Confinement (IEC) device (termed the C-device) has been developed for use as a 2.5-MeV D-D fusion neutron source for neutron activation analysis. The C-device employs a hollow-tube type cathode with similar anodes backed up by ''reflector'' dishes. The resulting discharge differs from a conventional hollow cathode discharge, by creating an explicit ion beam which is ''pinched'' in the cathode region. Resulting fusion reactions generate ∼10 6 neutron/s. A pulsed version is under development for applications requiring higher fluxes. Several pulsing techniques are under study, including an electron emitter (e-emitter) assisted discharge in a thorated tungsten wire emitter located behind a slotted area in the reflector dishes. Pulsing is initiated after establishing a low power steady-state discharge by pulsing the e-emitter current using a capacitor switch type circuit. The resulting electron jet, coupled with the discharge by the biased slot array, creates a strong pulse in the pinched ion beam. The pulse length/repetition rate are controlled by the e-emitter pulse circuit. Typical parameters in present studies are ∼30micros, 10Hz and 1-amp ion current. Corresponding neutron measurements are an In-foil type activation counter for time averaged rates. Results for a wide variety of operating conditions are presented

  15. Emittance and beam size distortion due to linear coupling

    International Nuclear Information System (INIS)

    Parzen, G.

    1993-01-01

    At injection, the presence of linear coupling may result in an increased beam emittance and in increased beam dimensions. Results for the emittance in the presence of linear coupling will be found. These results for the emittance distortion show that the harmonics of the skew quadrupole field close to ν x + ν y are the important harmonics. Results will be found for the important driving terms for the emittance distortion. It will be shown that if these driving terms are corrected, then the total emittance is unchanged, var-epsilon x + var-epsilon y = var-epsilon 1 + var-epsilon 2 . Also, the increase in the beam dimensions will be limited to a factor which is less than 1.414. If the correction is good enough, see below for details, one can achieve var-epsilon 1 = var-epsilon x , var-epsilon 2 = var-epsilon where var-epsilon 1 , var-epsilon 2 are the emittances in the presence of coupling, and the beam dimensions are unchanged. Global correction of the emittance and beam size distortion appears possible

  16. Radiation dosimetry in radiotherapy with internal emitters

    International Nuclear Information System (INIS)

    Stabin, Michael G.

    1997-01-01

    Full text. Radiation dosimetry radionuclides are currently being labeled to various biological agents used in internal emitter radiotherapy. This talk will review the various technologies and types of radiolabel in current use, with focus on the characterization of the radiation dose to the various important tissues of the body. Methods for obtaining data, developing kinetic models, and calculating radiation doses will be reviewed. Monoclonal antibodies are currently being labeled with both alpha and beta emitting radionuclides in attempts to find effective agents against cancer. Several radionuclides are also being used as bone pain palliation agents. These agents must be studied in clinical trials to determine the biokinetics and radiation dosimetry prior to approval for general use. In such studies, it is important to ensure the collection of the appropriate kinds of data and to collect the data at appropriate time intervals. The uptake and retention of activity in all significant source organs and in excreta be measured periodically (with at least 2 data points phase of uptake or clearance). Then, correct dosimetry methods must be applied - the best available methods for characterizing the radionuclide kinetic and for estimating the dosimetry in the various organs of the body especially the marrow, should be used. Attempts are also under way to develop methods for estimating true patient-specific dosimetry. Cellular and animal studies are also. Valuable in evaluating the efficacy of the agents in shrinking or eliminating tumors; some results from such studies will also be discussed. The estimation of radiation doses to patients in therapy with internal emitters involves several complex phases of analysis. Careful attention to detail and the use of the best available methods are essential to the protection of the patient and a successful outcome

  17. The Quantum Efficiency and Thermal Emittance of Metal Photocathodes

    International Nuclear Information System (INIS)

    Dowell, D.

    2009-01-01

    Modern electron beams have demonstrated the brilliance needed to drive free electron lasers at x-ray wavelengths, with the principle improvements occurring since the invention of the photocathode gun. The state-of-the-art normalized emittance electron beams are now becoming limited by the thermal emittance of the cathode. In both DC and RF photocathode guns, details of the cathode emission physics strongly influence the quantum efficiency and the thermal emittance. Therefore improving cathode performance is essential to increasing the brightness of beams. It is especially important to understand the fundamentals of cathode quantum efficiency and thermal emittance. This paper investigates the relationship between the quantum efficiency and the thermal emittance of metal cathodes using the Fermi-Dirac model for the electron distribution. We derive the thermal emittance and its relationship to the quantum efficiency, and compare our results to those of others

  18. t-Butyl group-substituted triphenylamine-containing orange-red fluorescent emitters for organic light-emitting diodes

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kum Hee; Kim, Chi Sik [Department of Chemistry, Sungkyunkwan University, Suwon, 440-746 (Korea, Republic of); Kim, Young Kwan, E-mail: kimyk@hongik.ac.kr [Department of Information Display, Hongik University, Seoul 121-791 (Korea, Republic of); Yoon, Seung Soo, E-mail: ssyoon@skku.edu [Department of Chemistry, Sungkyunkwan University, Suwon, 440-746 (Korea, Republic of)

    2012-03-30

    Efficient orange-red fluorescent compounds, 4-(dicyanomethylene)-2-adamantyl-6-(4-(N-(4-tert-butylphenyl) -N-(3,5-di-tert-butylphenyl)amino)benzene)vinyl-4H-pyran (DCATP) and 2,6-bis[4-(N-(4-tert-butylphenyl)-N-(3,5-di-tert-butylphenyl)amino)benzene] vinyl-4-(dicyanomethylene)-4H-pyran (BDCTP) containing the tert-butylated triphenylamine in donor moieties, were synthesized and characterized. In these red emitters, bulky groups, such as t-butyl group and adamantane were introduced to increase the steric hindrance between the red emitters. In particular, an efficient orange-red device containing the emitter DCATP as a dopant showed a luminous and power efficiency of 6.87 cd/A and 2.70 lm/W, respectively, at 20 mA/cm{sup 2} with the CIE coordinates of (0.48, 0.50) at 7.0 V. In addition, an efficient red organic light-emitting diode using BDCTP as a dopant exhibited a luminous and power efficiency of 2.30 cd/A and 1.31 lm/W, respectively, at 20 mA/cm{sup 2} and CIE coordinates of (0.61, 0.39). - Highlights: Black-Right-Pointing-Pointer Two orange-red emitters with t-butylated triphenylamine derivatives were studied. Black-Right-Pointing-Pointer We examine changes in electron D-A and electron D-A-D type in the terminal groups. Black-Right-Pointing-Pointer Electron D-A-D type material shows improved color chromaticity.

  19. Sterol synthesis. A novel reductive rearrangement of an alpha,beta-unsaturated steroidal epoxide; a new chemical synthesis of 5alpha-cholest-8(14)-en-3beta, 15alpha-diol.

    Science.gov (United States)

    Parish, E J; Schroepfer, G J

    1977-04-01

    Reduction of 3beta-benzoyloxy-14alpha,15alpha-epoxy-5alpha-cholest-7-ene with either lithium triethylboro-hydride or lithium aluminum hydride (4 molar excess) gave 5-alpha-cholest-8(14)-en-3beta,15alpha-diol in high yield. Reduction of the epoxy ester with lithium triethylborodeuteride or lithium aluminum deuteride (4 molar excess) gave [7alpha-2-H]-5alpha-cholest-8(14)-en-3beta,15alpha-diol. Reduction of 2beta-benzoyloxy-14alpha,15alpha-epoxy-5alpha-cholest-7-ene with a large excess (24 molar excess) of lithium aluminum hydride gave, in addition to the expected 5alpha-cholest-8(14)-en-3beta,15alpha-diol, a significant yield (33%) of 5alpha-cholest-8(14)-en-3beta-o1. Reduction of the epoxy ester with a large excess (24 molar excess) of lithium aluminum deuteride gave [7alpha-2H]-5alpha-cholest-8(14)-en-3beta,15alpha-diol and 5alpha-cholest-8(14)-en-3beta-o1 which contained two atoms of stably bound deuterium.

  20. Cooperative spontaneous emission of nano-emitters with inter-emitter coupling in a leaky microcavity

    International Nuclear Information System (INIS)

    Hong, Suc-Kyoung; Nam, Seog Woo; Yang, Hyung Jin

    2015-01-01

    We study the spontaneous emission from a few two-level nano-emitters placed in a leaky microcavity with Lorentzian spectral density near a critically damped regime. Collective features of the spontaneous emission are investigated by numerical analysis of the excitation dynamics when initially one nano-emitter is totally excited but we do not know which one. The results show that there are three decay rates in the excitation dynamics, two for simple exponential decays and one for damped oscillatory decay. The excitation dynamics is found to critically depend on the regime of the system. It is shown that the spontaneous emission is enhanced or suppressed depending on whether the system is in the underdamped or overdamped regime, respectively. On the other hand, the cooperative spontaneous emission is suppressed in the underdamped while it is enhanced in the overdamped regime. Furthermore, the effect of the direct inter-emitter coupling on the breaking of the cooperativeness of the spontaneous emission is shown as well. (paper)

  1. Microdistribution of uranium in kidney using alpha radiography of body animal

    International Nuclear Information System (INIS)

    Cebrian, D.; Morcillo, M. A.

    2006-01-01

    The radiation dose estimation after an internal contamination by a radionuclide requires the use of biokinetic and dosimetric models, which provide the tools for its calculation. The detailed knowledge of the biokinetic behaviour of the corresponding radionuclide is needed in order to build these models. Laboratory animals are employed to get this knowledge. In this context, the use of appropriate radioactivity measurement techniques is important to follow the distribution of the radionuclide within the organism. In this study an animal model of rat treated with uranyl citrate has been used. Sections of the whole animal are made at different times post-administration, and alpha autoradiography is performed with the slices in order to study the microdistribution of the uranium in the kidney. the utility of the alpha autoradiography whole body animal sections for the detailed study of the alpha emitters biodistribution is shown. (Author) 16 refs

  2. Aqueous extract of yellow maca (Lepidium meyenii) improves sperm count in experimental animals but response depends on hypocotyl size, pH and routes of administration.

    Science.gov (United States)

    Sanchez-Salazar, L; Gonzales, G F

    2018-04-01

    Lepidium meyenii, a Peruvian plant growing over 4000 m.a.s.l., has effects on nutrition and fertility. The purpose of this study was to evaluate the sperm count in 105 male mice receiving boiled aqueous extract of yellow maca hypocotyls from different sizes, under different pH conditions and using two different routes of administration. Five mice per group were treated daily for 3 days with vehicle (oral and intraperitoneal) or maca aqueous extracts (5 mg/0.5 ml/day) belonging to the first, second, third and fourth categories, according to their hypocotyl size. On day four, sperm count was evaluated at testis, epididymis and vas deferens. Sperm count was higher in mice receiving maca from the larger sizes (first and second categories). Reduction in maca extract pH increased sperm count, whereas an increase in the pH resulted in a reduction in sperm count. The effect of pH reduction is observed only in maca from the first and second categories. Aqueous extract of maca was effective only after oral administration. In conclusion, the larger size of hypocotyls presented the best biological effect, and the low pH in the extract and the transformation after gastrointestinal passage are both important for its biological action. © 2017 Blackwell Verlag GmbH.

  3. Immunological Enhancement of Interferon Alpha Treatment to Allogeneic Bone Marrow Transplantation in Irradiated Rats

    International Nuclear Information System (INIS)

    Hussein, E.M.; Abd El-Naby, Y.H.

    2011-01-01

    The Influence of the biological response modifiers: interferon alpha (IFN-α) and bone marrow transplantation (BMT) on stimulation of blood cell recovery and boosting the immunological response were investigated in this work. Male rats received BMT 3 h post total body ?-irradiation of 5 Gy and were injected with 10 units of IFN-α weekly for 5 weeks. Irradiation induced a significant decrease in blood parameters, reduced glutathione (GSH) as well as bone marrow lymphocyte count and viability. Immunological data revealed that tumour necrosis factor alpha (TNF-α) and interleukin-2 (IL-2) recorded a significant depression while lipid peroxidation (MDA) was conversely elevated. White blood cells (WBC), erythrocytes (RBC), haemoglobin (Hb), haematocrit (Hct), lymphocytes and GSH in irradiated animals receiving BMT and IFN-α, were significantly elevated, while MDA was significantly depressed as compared to the irradiated group. Bone marrow lymphocytic count and viability percentage were significantly increased while IL-2 and TNF-α were normalized. The curative action of IFN-α enforcing significant innate response could trigger and augment adaptive immune response by bone marrow transplantation. Such therapies boosting both components of immunity would be considered a potential strategy for irradiation treatment

  4. Performances of the Alpha-X RF gun on the PHIL accelerator at LAL

    Energy Technology Data Exchange (ETDEWEB)

    Vinatier, T., E-mail: vinatier@lal.in2p3.fr [Laboratoire de l' Accélérateur Linéaire (LAL), Université Paris Sud, UMR 8607, bâtiment 200, 91898 Orsay Cedex (France); Bruni, C. [Laboratoire de l' Accélérateur Linéaire (LAL), Université Paris Sud, UMR 8607, bâtiment 200, 91898 Orsay Cedex (France); Roux, R. [Laboratoire de l' Accélérateur Linéaire (LAL), Université Paris Sud, UMR 8607, bâtiment 200, 91898 Orsay Cedex (France); Laboratoire d' Etude des Eléments Légers, CEA IRAMIS, bâtiment 524, 91191 Gif sur Yvette Cedex (France); Brossard, J. [Laboratoire de l' Accélérateur Linéaire (LAL), Université Paris Sud, UMR 8607, bâtiment 200, 91898 Orsay Cedex (France); Laboratoire Astroparticule et Cosmologie, Université Paris 7, UMR 7164, bâtiment Condorcet, 75205 Paris Cedex (France); Chancé, S.; Cayla, J.N.; Chaumat, V. [Laboratoire de l' Accélérateur Linéaire (LAL), Université Paris Sud, UMR 8607, bâtiment 200, 91898 Orsay Cedex (France); and others

    2015-10-11

    The Alpha-X RF-gun was designed to produce an ultra-short (<100 fs rms), 100 pC and 6.3 MeV electron beam with a normalized rms transverse emittance of 1π mm mrad for a gun peak accelerating field of 100 MV/m. Such beams will be required by the Alpha-X project, which aims to study a laser-driven plasma accelerator with a short wavelength accelerating medium. It has been demonstrated on PHIL (Photo-Injector at LAL) that the coaxial RF coupling, chosen to preserve the gun field cylindrical symmetry, is perfectly understood and allows reaching the required peak accelerating field of 100 MV/m giving beam energy of 6.3 MeV. Moreover, a quite low beam rms relative energy spread of 0.15% at 3.8 MeV has been measured, completely agreeing with simulations. Dark current, quantum efficiencies and dephasing curves measurements have also been performed. They all show high values of the field enhancement factor β, which can be explained by the preparation of the photocathodes. Finally, measurements on the transverse phase-space have been carried out, with some limitations given by the difficult modelization of one of the PHIL solenoid magnets and by the enlargement of the beam transverse dimensions due to the use of YAG screens. These measurements give a normalized rms transverse emittance around 5π mm mrad, which does not fulfill the requirement for the Alpha-X project.

  5. Emittance scanner for intense low-energy ion beams

    International Nuclear Information System (INIS)

    Allison, P.W.; Sherman, J.D.; Holtkamp, D.B.

    1983-01-01

    An emittance scanner has been developed for use with low-energy H - ion beams to satisfy the following requirements: (1) angular resolution of +-1/2 mrad, (2) small errors from beam space charge, and (3) compact and simple design. The scanner consists of a 10-cm-long analyzer containing two slits and a pair of electric deflection plates driven by a +-500-V linear ramp generator. As the analyzer is mechanically driven across the beam, the front slit passes a thin ribbon of beam through the plates. The ion transit time is short compared with the ramp speed; therefore, the initial angle of the ions that pass through the rear slit is proportional to the instantaneous ramp voltage. The current through the rear slit then is proportional to the phase-space density d 2 i/dxdx'. The data are computer-analyzed to give, for example, rms emittance and phase-space density contours. Comparison of measured data with those calculated from a prepared (collimated) phase space is in good agreement

  6. Use of proportional gas scintillator in absolute measurements of alpha-gamma emitter activities

    International Nuclear Information System (INIS)

    Tobias, C.C.B.

    1987-01-01

    The absolute activity of U-235 contained in a U 3 O 8 sample was measured utilizing a sum-coincidence circuit which selects only the alpha particles which are simultaneous with the 143 KeV and 186 KeV gamma radiations from the Th-231 (product nucleus). The alpha particles were detected by means of a new type of a gas scintillating chamber, in which the light emitted by excitation of the gas atoms, due to the passage of a charged incoming particle, has its intensity increased by the action of an applied electric field. The gamma radiations were detected by means of a NaI(Tl) 1'' x 1 1/2'' scintillation detector. The value obtained for the half-life of U-235 was compared with the data available from various observers which used different experimental techniques. It is shown tht the results, are in excellent agreement with the best international data available on the subject and that, therefore, the sum-coincidence technique constitutes an important method for such measurements. (Author) [pt

  7. Measurement of radon progeny concentrations in air by alpha-particle spectrometey

    International Nuclear Information System (INIS)

    Kerr, G.D.

    1975-07-01

    A technique is presented for measuring air concentrations of the short-lived progeny of radon-222 by the use of alpha spectrometry. In this technique, the concentration of RaA, RaB, and RaC are calculated from one integral count of the RaA and two integral counts of the RaC' alpha-particle activity collected on a filter with an air sampling device. The influence of air sampling and counting intervals of time on the accuracy of the calculated concentrations is discussed in the report. A computer program is presented for use with this technique. It is written in the BASIC language. The program will calculate the air concentrations of RaA, RaB, and RaC, and will estimate the accuracy in these calculated concentrations. (U.S.)

  8. Actions of alpha2 adrenoceptor ligands at alpha2A and 5-HT1A receptors: the antagonist, atipamezole, and the agonist, dexmedetomidine, are highly selective for alpha2A adrenoceptors.

    Science.gov (United States)

    Newman-Tancredi, A; Nicolas, J P; Audinot, V; Gavaudan, S; Verrièle, L; Touzard, M; Chaput, C; Richard, N; Millan, M J

    1998-08-01

    This study examined the activity of chemically diverse alpha2 adrenoceptor ligands at recombinant human (h) and native rat (r) alpha2A adrenoceptors compared with 5-HT1A receptors. First, in competition binding experiments at h alpha2A and h5-HT1A receptors expressed in CHO cells, several compounds, including the antagonists 1-(2-pyrimidinyl)piperazine (1-PP), (+/-)-idazoxan, benalfocin (SKF 86466), yohimbine and RX 821,002, displayed preference for h alpha2A versus h5-HT1A receptors of only 1.4-, 3.6-, 4-, 10- and 11-fold, respectively (based on differences in pKi values). Clonidine, brimonidine (UK 14304), the benzopyrrolidine fluparoxan and the guanidines guanfacine and guanabenz exhibited intermediate selectivity (22- to 31-fold) for h alpha2A receptors. Only the antagonist atipamezole and the agonist dexmedetomidine (DMT) displayed high preference for alpha2 adrenoceptors (1290- and 91-fold, respectively). Second, the compounds were tested for their ability to induce h5-HT1A receptor-mediated G-protein activation, as indicated by the stimulation of [35S]GTPgammaS binding. All except atipamezole and RX 821,002 exhibited agonist activity, with potencies which correlated with their affinity for h5-HT1A receptors. Relative efficacies (Emax values) were 25-35% for guanabenz, guanfacine, WB 4101 and benalfocin, 50-65% for 1-PP, (+/-)-idazoxan and clonidine, and over 70% for fluparoxan, oxymetazoline and yohimbine (relative to 5-HT = 100%). Yohimbine-induced [35S]GTPgammaS binding was inhibited by the selective 5-HT1A receptor antagonist WAY 100,635. In contrast, RX 821,002 was the only ligand which exhibited antagonist activity at h5-HT1A receptors, inhibiting 5-HT-stimulated [35S]GTPgammaS binding. Atipamezole, which exhibited negligeable affinity for 5-HT1A receptors, was inactive. Third, the affinities for r alpha2A differed considerably from the affinities for h alpha2A receptors whereas the affinities for r5-HT1A differed much less from the affinities for h5-HT

  9. Diamondoid monolayers as electron emitters

    Science.gov (United States)

    Yang, Wanli [El Cerrito, CA; Fabbri, Jason D [San Francisco, CA; Melosh, Nicholas A [Menlo Park, CA; Hussain, Zahid [Orinda, CA; Shen, Zhi-Xun [Stanford, CA

    2012-04-10

    Provided are electron emitters based upon diamondoid monolayers, preferably self-assembled higher diamondoid monolayers. High intensity electron emission has been demonstrated employing such diamondoid monolayers, particularly when the monolayers are comprised of higher diamondoids. The application of such diamondoid monolayers can alter the band structure of substrates, as well as emit monochromatic electrons, and the high intensity electron emissions can also greatly improve the efficiency of field-effect electron emitters as applied to industrial and commercial applications.

  10. High quality GaAs single photon emitters on Si substrate

    International Nuclear Information System (INIS)

    Bietti, S.; Sanguinetti, S.; Cavigli, L.; Accanto, N.; Vinattieri, A.; Minari, S.; Abbarchi, M.; Isella, G.; Frigeri, C.; Gurioli, M.

    2013-01-01

    We describe a method for the direct epitaxial growth of a single photon emitter, based on GaAs quantum dots fabricated by droplet epitaxy, working at liquid nitrogen temperatures on Si substrates. The achievement of quantum photon statistics up to T=80 K is directly proved by antibunching in the second order correlation function as measured with a H anbury Brown and Twiss interferometer

  11. Tolerances for the vertical emittance in damping rings

    International Nuclear Information System (INIS)

    Raubenheimer, T.O.

    1991-11-01

    Future damping rings for linear colliders will need to have very small vertical emittances. In the limit of low beam current, the vertical emittance is primarily determined by the vertical dispersion and the betatron coupling. In this paper, the contributions to these effects from random misalignments are calculated and tolerances are derived to limit the vertical emittance with a 95% confidence level. 10 refs., 5 figs

  12. Beam emittance measurements on multicusp ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Sarstedt, M.; Lee, Y.; Leung, K.N. [and others

    1995-08-01

    Multicusp ion sources are used for various applications. Presently, the implementation of this type of ion source planned for the development of an ion beam lithography machine, which will be used for the projection of sub-0.2 {mu}m patterns onto a wafer substrate. Since, for this application, a very good beam quality and a small ion energy spread are required, emittance measurements have been performed on a multicusp ion source for various source conditions. It is shown that the installation of proper capacitors between the extraction electrodes is necessary to avoid rf-pickup, which otherwise leads to a distortion of the beam emittance. The influence of the magnetic filter field on the beam emittance has been investigated, and the beam emittance of a dc filament-discharge plasma has also been compared to that of an rf-generated plasma.

  13. Beam emittance measurements on multicusp ion sources

    International Nuclear Information System (INIS)

    Sarstedt, M.; Lee, Y.; Leung, K.N.

    1995-08-01

    Multicusp ion sources are used for various applications. Presently, the implementation of this type of ion source planned for the development of an ion beam lithography machine, which will be used for the projection of sub-0.2 μm patterns onto a wafer substrate. Since, for this application, a very good beam quality and a small ion energy spread are required, emittance measurements have been performed on a multicusp ion source for various source conditions. It is shown that the installation of proper capacitors between the extraction electrodes is necessary to avoid rf-pickup, which otherwise leads to a distortion of the beam emittance. The influence of the magnetic filter field on the beam emittance has been investigated, and the beam emittance of a dc filament-discharge plasma has also been compared to that of an rf-generated plasma

  14. Intraoperative detection of ¹⁸F-FDG-avid tissue sites using the increased probe counting efficiency of the K-alpha probe design and variance-based statistical analysis with the three-sigma criteria.

    Science.gov (United States)

    Povoski, Stephen P; Chapman, Gregg J; Murrey, Douglas A; Lee, Robert; Martin, Edward W; Hall, Nathan C

    2013-03-04

    Intraoperative detection of (18)F-FDG-avid tissue sites during 18F-FDG-directed surgery can be very challenging when utilizing gamma detection probes that rely on a fixed target-to-background (T/B) ratio (ratiometric threshold) for determination of probe positivity. The purpose of our study was to evaluate the counting efficiency and the success rate of in situ intraoperative detection of (18)F-FDG-avid tissue sites (using the three-sigma statistical threshold criteria method and the ratiometric threshold criteria method) for three different gamma detection probe systems. Of 58 patients undergoing (18)F-FDG-directed surgery for known or suspected malignancy using gamma detection probes, we identified nine (18)F-FDG-avid tissue sites (from amongst seven patients) that were seen on same-day preoperative diagnostic PET/CT imaging, and for which each (18)F-FDG-avid tissue site underwent attempted in situ intraoperative detection concurrently using three gamma detection probe systems (K-alpha probe, and two commercially-available PET-probe systems), and then were subsequently surgical excised. The mean relative probe counting efficiency ratio was 6.9 (± 4.4, range 2.2-15.4) for the K-alpha probe, as compared to 1.5 (± 0.3, range 1.0-2.1) and 1.0 (± 0, range 1.0-1.0), respectively, for two commercially-available PET-probe systems (P < 0.001). Successful in situ intraoperative detection of 18F-FDG-avid tissue sites was more frequently accomplished with each of the three gamma detection probes tested by using the three-sigma statistical threshold criteria method than by using the ratiometric threshold criteria method, specifically with the three-sigma statistical threshold criteria method being significantly better than the ratiometric threshold criteria method for determining probe positivity for the K-alpha probe (P = 0.05). Our results suggest that the improved probe counting efficiency of the K-alpha probe design used in conjunction with the three-sigma statistical

  15. Targeted alpha therapy of mCRPC. Dosimetry estimate of {sup 213}bismuth-PSMA-617

    Energy Technology Data Exchange (ETDEWEB)

    Kratochwil, Clemens; Afshar-Oromieh, Ali; Rathke, Hendrik; Giesel, Frederik L. [University Hospital Heidelberg, Department of Nuclear Medicine, Heidelberg (Germany); Schmidt, Karl [ABX-CRO, Dresden (Germany); Bruchertseifer, Frank; Morgenstern, Alfred [European Commission - Joint Research Centre, Directorate for Nuclear Safety and Security, Karlsruhe (Germany); Haberkorn, Uwe [University Hospital Heidelberg, Department of Nuclear Medicine, Heidelberg (Germany); German Cancer Research Center (DKFZ), Cooperation Unit Nuclear Medicine, Heidelberg (Germany)

    2018-01-15

    PSMA-617 is a small molecule targeting the prostate-specific membrane antigen (PSMA). In this work, we estimate the radiation dosimetry for this ligand labeled with the alpha-emitter {sup 213}Bi. Three patients with metastatic prostate cancer underwent PET scans 0.1 h, 1 h, 2 h, 3 h, 4 h and 5 h after injection of {sup 68}Ga-PSMA-617. Source organs were kidneys, liver, spleen, salivary glands, bladder, red marrow and representative tumor lesions. The imaging nuclide {sup 68}Ga was extrapolated to the half-life of {sup 213}Bi. The residence times of {sup 213}Bi were forwarded to the instable daughter nuclides. OLINDA was used for dosimetry calculation. Results are discussed in comparison to literature data for {sup 225}Ac-PSMA-617. Assuming a relative biological effectiveness of 5 for alpha radiation, the dosimetry estimate revealed equivalent doses of mean 8.1 Sv{sub RBE5}/GBq for salivary glands, 8.1 Sv{sub RBE5}/GBq for kidneys and 0.52 Sv{sub RBE5}/GBq for red marrow. Liver (1.2 Sv{sub RBE5}/GBq), spleen (1.4 Sv{sub RBE5}/GBq), bladder (0.28 Sv{sub RBE5}/GBq) and other organs (0.26 Sv{sub RBE5}/GBq) were not dose-limiting. The effective dose is 0.56 Sv{sub RBE5}/GBq. Tumor lesions were in the range 3.2-9.0 Sv{sub RBE5}/GBq (median 7.6 Sv{sub RBE5}/GBq). Kidneys would limit the cumulative treatment activity to 3.7 GBq; red marrow might limit the maximum single fraction to 2 GBq. Despite promising results, the therapeutic index was inferior compared to {sup 225}Ac-PSMA-617. Dosimetry of {sup 213}Bi-PSMA-617 is in a range traditionally considered reasonable for clinical application. Nevertheless, compared to {sup 225}Ac-PSMA-617, it suffers from higher perfusion-dependent off-target radiation and a longer biological half-life of PSMA-617 in dose-limiting organs than the physical half-life of {sup 213}Bi, rendering this nuclide as a second choice radiolabel for targeted alpha therapy of prostate cancer. (orig.)

  16. Proposal of a weight factor for alpha radiation aiming biota radioprotection

    International Nuclear Information System (INIS)

    Pereira, Wagner de S.; Py Junior, Delcy de A.; Kelecom, Alphonse; Goncalves, Simone

    2009-01-01

    Several proposals based on the environmental radioprotection of calculating the absorbed dose in biota have been suggested. The absorbed dose expresses the deposition of energy per mass unit. The differences in biological effects of the absorbed dose can be quantified by applying a correction factor to the absorbed dose. The correction factor for radiation is easier to establish, because radiations exist in smaller number (alpha, beta, neutrons and photons) and can be set for groups of organisms. This work aims to propose a correction factor for radiation, in order to adequate the concept of absorbed dose currently used to the concept of equivalent dose. A survey of the literature on correction factors proposed for alpha radiation was carried out and, when possible, the biological endpoint was identified, as well as the radionuclide and the biological target. A variation of the weight factor for alpha radiation from 1 to 377 was observed and a number of biological endpoints, biological target and alpha emitter radionuclide were identified. Finally we propose a weight value for alpha radiation of 40, and we propose also the name of correction factor for radiation alpha as being ecological radiation weighting factor (WRE) the name 'equivalent dose for flora and fauna' (HTFF) to name of the new dose. (author)

  17. Programmable automatic alpha--beta air sample counter

    International Nuclear Information System (INIS)

    Howell, W.P.

    1978-01-01

    A programmable automatic alpha-beta air sample counter was developed for routine sample counting by operational health physics personnel. The system is composed of an automatic sample changer utilizing a large silicon diode detector, an electronic counting system with energy analysis capability, an automatic data acquisition controller, an interface module, and a teletypewriter with paper tape punch and paper tape reader. The system is operated through the teletypewriter keyboard and the paper tape reader, which are used to instruct the automatic data acquisition controller. Paper tape programs are provided for background counting, Chi 2 test, and sample counting. Output data are printed by the teletypewriter on standard continuous roll or multifold paper. Data are automatically corrected for background and counter efficiency

  18. Test results on two thermionic converters with cermet emitters

    International Nuclear Information System (INIS)

    Saunders, M.; Danielson, L.; Huffman, F.

    1983-01-01

    An emitter made of a directionally solidified Mo-Al 2 O 3 , Cr 2 O 3 eutectic was provided by Eindhoven University of Technology in Eindhoven, The Netherlands. Although the high temperature braze cycle used in bonding this electrode to the emitter substrate destroyed its characteristic needle microstructure, the converter gave good performance. Apparently, chemical species evaporated from the emitter onto the collector provided a low collector work function. The resulting low barrier indices suggest that this surface is a promising emitter

  19. Response of brain oxygenation and metabolism to deep hypothermic circulatory arrest in newborn piglets: comparison of pH-stat and alpha-stat strategies.

    Science.gov (United States)

    Markowitz, Scott D; Mendoza-Paredes, Alberto; Liu, Huiping; Pastuszko, Peter; Schultz, Steven P; Schears, Gregory J; Greeley, William J; Wilson, David F; Pastuszko, Anna

    2007-07-01

    To determine the effect of pH-stat as compared with alpha-stat management on brain oxygenation, level of striatal extracellular dopamine, phosphorylation, and levels of protein kinase B (Akt) and cyclic adenosine 3', 5'-monophosphate response element-binding protein (CREB), and levels of extracellular signal-regulated kinase (ERK)1/2, Bcl-2, and Bax in a piglet model of deep hypothermic circulatory arrest (DHCA). The piglets were placed on cardiopulmonary bypass (CPB), cooled with pH-stat or alpha-stat to 18 degrees C, subjected to 90 minutes of DHCA, rewarmed, weaned from CPB, and maintained for two hours recovery. The cortical oxygen was measured by: quenching of phosphorescence; dopamine by microdialysis; phosphorylation of CREB (p-CREB), ERK (p-ERK) 1/2, Akt (p-Akt), and level of Bcl-2, Bax by Western blots. Oxygen pressure histograms for the microvasculature of the cortex show substantially higher oxygen levels during cooling and during the oxygen depletion period after cardiac arrest (up to 15 minutes) when using pH-stat compared with alpha-stat management. Significant increases in dopamine occurred at 45 minutes and 60 minutes of DHCA in the alpha-stat and pH-stat groups, respectively. The p-CREB and p-Akt in the pH-stat group were significantly higher than in the alpha-stat group (140 +/- 9%, p model, prolongs "safe" time of DHCA and provides some brain protection against ischemic injury.

  20. Hydrogen cluster/network in tobermorite as studied by multiple-quantum spin counting {sup 1}H NMR

    Energy Technology Data Exchange (ETDEWEB)

    Mogami, Yuuki [Division of Chemistry, Graduate School of Science, Kyoto University, Kyoto 606-8502 (Japan); Yamazaki, Satoru; Matsuno, Shinya [Analysis and Simulation Center, Asahi Kasei Corporation, Fuji, Shizuoka 416-8501 (Japan); Matsui, Kunio [Products and Marketing Development Dept., Asahi Kasei Construction Materials Corporation, Sakai-machi, Ibaraki 306-0493 (Japan); Noda, Yasuto [Division of Chemistry, Graduate School of Science, Kyoto University, Kyoto 606-8502 (Japan); Takegoshi, K., E-mail: takeyan@kuchem.kyoto-u.ac.jp [Division of Chemistry, Graduate School of Science, Kyoto University, Kyoto 606-8502 (Japan)

    2014-12-15

    Proton multiple-quantum (MQ) spin-counting experiment has been employed to study arrangement of hydrogen atoms in 9 Å/11 Å natural/synthetic tobermorites. Even though all tobermorite samples give similar characterless, broad static-powder {sup 1}H NMR spectra, their MQ spin-counting spectra are markedly different; higher quanta in 11 Å tobermorite do not grow with the MQ excitation time, while those in 9 Å one do. A statistical analysis of the MQ results recently proposed [26] is applied to show that hydrogens align in 9 Å tobermorite one dimensionally, while in 11 Å tobermorite they exist as a cluster of 5–8 hydrogen atoms.

  1. Design and device construction for plane tables preparation for counter alpha/beta total

    International Nuclear Information System (INIS)

    Galicia C, F. J.; Monroy G, F.

    2014-10-01

    This work presents the design and assembly of a device for plane tables preparation for quantification alpha/beta total of radioactive waste samples. The determination of the activity index alpha/beta total is used to detect a wide variety of matrices quickly and the concentration of alpha and/or beta emitters of the contained radionuclides in different samples. In particular, the determination of the activity index alpha and beta total of radioactive wastes involves the digestion of samples in aggressive means that will be evaporated to dryness for its quantification. With the purpose of controlling the emission of corrosive gases during the preparation of the plane tables for the quantification of the index alpha and beta total, was designed and built the device in the Radioactive Waste Laboratory that allows to prepare plane tables for proportional counters in a sure and efficient way. The device is constituted by heating equipment, evaporation cylinder and a gases cleaning system. The self-absorption curve got ready starting from the device. (Author)

  2. Transverse emittance growth in staged laser-wakefield acceleration

    Directory of Open Access Journals (Sweden)

    T. Mehrling

    2012-11-01

    Full Text Available We present a study on the emittance evolution of electron bunches, externally injected into laser-driven plasma waves using the three-dimensional particle-in-cell (PIC code OSIRIS. Results show order-of-magnitude transverse emittance growth during the injection process, if the electron bunch is not matched to its intrinsic betatron motion inside the wakefield. This behavior is supported by analytic theory reproducing the simulation data to a percent level. The length over which the full emittance growth develops is found to be less than or comparable to the typical dimension of a single plasma module in current multistage designs. In addition, the analytic theory enables the quantitative prediction of emittance degradation in two consecutive accelerators coupled by free-drift sections, excluding this as a scheme for effective emittance-growth suppression, and thus suggests the necessity of beam-matching sections between acceleration stages with fundamental implications on the overall design of staged laser-wakefield accelerators.

  3. Study of the peak shape in alpha spectra measured by liquid scintillation

    CERN Document Server

    Vera-Tome, F; Martin-Sanchez, A

    2002-01-01

    Liquid-scintillation counting allows the measurement of alpha and beta activities jointly or only of the alpha-emitting nuclides in a sample. Although the resolution of the alpha spectra is poorer than that attained with semiconductor detectors, it is still an attractive alternative. We describe here attempts to fit a peak shape to experimental liquid-scintillation alpha spectra and discuss the parameters affecting this shape, such as the PSA (pulse-shape analyser) level, vial type, shaking the sample, etc. Spectral analysis has been applied for complex alpha spectra.

  4. Emittance Growth during Bunch Compression in the CTF-II

    Energy Technology Data Exchange (ETDEWEB)

    Raubenheimer, Tor O

    1999-02-26

    Measurements of the beam emittance during bunch compression in the CLIC Test Facility (CTF-II) are described. The measurements were made with different beam charges and different energy correlations versus the bunch compressor settings which were varied from no compression through the point of full compression and to over-compression. Significant increases in the beam emittance were observed with the maximum emittance occurring near the point of full (maximal) compression. Finally, evaluation of possible emittance dilution mechanisms indicate that coherent synchrotron radiation was the most likely cause.

  5. Electrohydrodynamic emitters of ion beams

    International Nuclear Information System (INIS)

    Dudnikov, V.G.; Shabalin, A.L.

    1990-01-01

    Physical processes determining generation of ion beams with high emission current density in electrohydrodynamic emitters are considered. Electrohydrodynamic effects developing in ion emission features and kinetics of ion interaction in beams with high density are discussed. Factors determining the size of the emission zone, emission stability at high and low currents, cluster generation, increase of energy spread and decrease of brightness are analyzed. Problems on practical provision of stable EHD emitter functioning are considered. 94 refs.; 8 figs.; 1 tab

  6. MEASUREMENT OF RADIONUCLIDES USING ION CHROMATOGRAPHY AND FLOW-CELL SCINTILLATION COUNTING WITH PULSE SHAPE DISCRIMINATION

    International Nuclear Information System (INIS)

    Fjeld, R. A.; DeVol, T.A.; Leyba, J.D.

    2000-01-01

    Radiological characterization and monitoring is an important component of environmental management activities throughout the Department of Energy complex. Gamma-ray spectroscopy is the technology most often used for the detection of radionuclides. However, radionuclides which cannot easily be detected by gamma-ray spectroscopy, such as pure beta emitters and transuranics, pose special problems because their quantification generally requires labor intensive radiochemical separations procedures that are time consuming and impractical for field applications. This project focused on a technology for measuring transuranics and pure beta emitters relatively quickly and has the potential of being field deployable. The technology combines ion exchange liquid chromatography and on-line alpha/beta pulse shape discriminating scintillation counting to produce simultaneous alpha and beta chromatograms. The basic instrumentation upon which the project was based was purchased in the early 1990's. In its original commercial form, the instrumentation was capable of separating select activation/fission products in ionic forms from relatively pure aqueous samples. We subsequently developed the capability of separating and detecting actinides (thorium, uranium, neptunium, plutonium, americium, and curium) in less than 30 minutes (Reboul, 1993) and realized that the potential time savings over traditional radiochemical methods for isolating some of these radionuclides was significant. However, at that time, the technique had only been used for radionuclide concentrations that were considerably above environmental levels and for aqueous samples of relatively high chemical purity. For the technique to be useful in environmental applications, development work was needed in lowering detection limits; to be useful in applications involving non-aqueous matrices such as soils and sludges or complex aqueous matrices such as those encountered in waste samples, development work was needed in

  7. Emittance measurements in low energy ion storage rings

    Science.gov (United States)

    Hunt, J. R.; Carli, C.; Resta-López, J.; Welsch, C. P.

    2018-07-01

    The development of the next generation of ultra-low energy antiproton and ion facilities requires precise information about the beam emittance to guarantee optimum performance. In the Extra-Low ENergy Antiproton storage ring (ELENA) the transverse emittances will be measured by scraping. However, this diagnostic measurement faces several challenges: non-zero dispersion, non-Gaussian beam distributions due to effects of the electron cooler and various systematic errors such as closed orbit offsets and inaccurate rms momentum spread estimation. In addition, diffusion processes, such as intra-beam scattering might lead to emittance overestimates. Here, we present algorithms to efficiently address the emittance reconstruction in presence of the above effects, and present simulation results for the case of ELENA.

  8. Fabrication of heterojunction solar cells by using microcrystalline hydrogenated silicon oxide film as an emitter

    International Nuclear Information System (INIS)

    Banerjee, Chandan; Sritharathikhun, Jaran; Konagai, Makoto; Yamada, Akira

    2008-01-01

    Wide gap, highly conducting n-type hydrogenated microcrystalline silicon oxide (μc-SiO : H) films were prepared by very high frequency plasma enhanced chemical vapour deposition at a very low substrate temperature (170 deg. C) as an alternative to amorphous silicon (a-Si : H) for use as an emitter layer of heterojunction solar cells. The optoelectronic properties of n-μc-SiO : H films prepared for the emitter layer are dark conductivity = 0.51 S cm -1 at 20 nm thin film, activation energy = 23 meV and E 04 = 2.3 eV. Czochralski-grown 380 μm thick p-type (1 0 0) oriented polished silicon wafers with a resistivity of 1-10 Ω cm were used for the fabrication of heterojunction solar cells. Photovoltaic parameters of the device were found to be V oc = 620 mV, J sc = 32.1 mA cm -2 , FF = 0.77, η = 15.32% (active area efficiency)

  9. Transverse emittance measurement and preservation at the LHC

    Energy Technology Data Exchange (ETDEWEB)

    Kuhn, Maria

    2016-06-20

    The Large Hadron Collider (LHC) at CERN is a high energy storage ring that provides proton and heavy ion collisions to study fundamental particle physics. The luminosity production is closely linked to emittance preservation in the accelerator. The transverse emittance is the phase space density of the beam and should be conserved when the particle beam is transformed through the accelerator. Perturbing effects, however, can lead to emittance increase and hence luminosity degradation. Measuring the emittance growth is a complex task with high intensity beams and changing energies. The machine optics and the transverse beam size have to be measured as accurately as possible. Beta function measurements with k-modulation are discussed. With this method the quadrupole focussing strength is varied and the resulting tune change is traced to determine the beta function at the quadrupole. A new k-modulation measurement tool was developed for the LHC. The fully automatic and online measurement system takes constraints of various systems such as tune measurement precision and powering limitations of the LHC superconducting circuits into account. With sinusoidal k-modulation record low beta function measurement uncertainties in the LHC have been reached. 2015 LHC beta function and β*, which is the beta function at the collision point, measurements with k-modulation will be presented. Wire scanners and synchrotron light monitors are presently used in the LHC to measure the transverse beam size. Accuracy and limitations of the LHC transverse profile monitors are discussed. During the 2012 LHC proton run it was found that wire scanner photomultiplier saturation added significant uncertainty on all measurements. A large discrepancy between emittances from wire scanners and luminosity was discovered but not solved. During Long Shutdown 1 the wire scanner system was upgraded with new photomultipliers. A thorough study of LHC wire scanner measurement precision in 2015 is presented

  10. Improvements in emittance wake field optimization for the SLAC Linear Collider

    CERN Document Server

    Decker, Franz Josef

    2003-01-01

    The transverse emittances in the SLAC Linear Collider can be severely diluted by collective wakefield effects and dispersion. For the 1997/98 SLC/SLD run important changes were implemented in the way the emittance is optimized. Early in the linac, where the energy spread is large due to BNS damping, the emittance growth is dominated by dispersion. In this regime emittance tuning bumps may introduce additional wakefield tails and their use is now avoided. At the end of the linac the energy spread is minimal and the emittance measurement is most sensitive to wakefield emittance dilution. In previous years, the emittances were tuned on wire scanners located near but not at the end of the linac (after about 90% of its length). Simulations show that emittance growth of up to 100% can occur in the remaining 10%. In this run wire scanners at the entrance of the Final Focus, the last place where the emittances can be measured, were used for the optimization. Screens at the end of the linac allow additional real time ...

  11. Field emission characteristics of a small number of carbon fiber emitters

    Directory of Open Access Journals (Sweden)

    Wilkin W. Tang

    2016-09-01

    Full Text Available This paper reports an experiment that studies the emission characteristics of small number of field emitters. The experiment consists of nine carbon fibers in a square configuration. Experimental results show that the emission characteristics depend strongly on the separation between each emitter, providing evidence of the electric field screening effects. Our results indicate that as the separation between the emitters decreases, the emission current for a given voltage also decreases. The authors compare the experimental results to four carbon fiber emitters in a linear and square configurations as well as to two carbon fiber emitters in a paired array. Voltage-current traces show that the turn-on voltage is always larger for the nine carbon fiber emitters as compared to the two and four emitters in linear configurations, and approximately identical to the four emitters in a square configuration. The observations and analysis reported here, based on Fowler-Nordheim field emission theory, suggest the electric field screening effect depends critically on the number of emitters, the separation between them, and their overall geometric configuration.

  12. Emittance calculations for the Stanford Linear Collider injector

    International Nuclear Information System (INIS)

    Sheppard, J.C.; Clendenin, J.E.; Helm, R.H.; Lee, M.J.; Miller, R.H.; Blocker, C.A.

    1983-03-01

    A series of measurements have been performed to determine the emittance of the high intensity, single bunch beam that is to be injected into the Stanford Linear Collider. On-line computer programs were used to control the Linac for the purpose of data acquisition and to fit the data to a model in order to deduce the beam emittance. This paper will describe the method of emittance calculation and present some of the measurement results

  13. A new crystal whole-body scanner for positron emitters

    International Nuclear Information System (INIS)

    Ostertag, H.; Kuebler, W.; Kubesch, R.; Lorenz, W.J.; Woerner, P.

    1980-01-01

    A multicrystal whole body scanner for positron emitters has been constructed. The annihilation quanta are measured in two opposing detector banks. Each detector bank consists of 64 NaI crystals of 1.5'' diameter x 3'' length. Directly opposing single detectors are in coincidence. The patient moves linearly between the stationary transverse detector banks. The scanning area of the system is 64 x 192 cm 2 . The spatial resolution is 2 cm at a sampling distance of 1 cm. The sensitivity is 6400 counts/s for a pure positron flood source with 1 μCi/cm 2 . The system is controlled by a microcomputer (DEC LSI-11). The scintigrams are shown on a display. Absolute activities can be calculated by mathematical comparison of consecutive emission and transmission scans. The design of the positron scanner and its capacibilities are described. Experimental and initial clinical results are presented. (author)

  14. Measuring Academic Performance for Healthcare Researchers with the H Index: Which Search Tool Should Be Used?

    Science.gov (United States)

    Patel, Vanash M.; Ashrafian, Hutan; Almoudaris, Alex; Makanjuola, Jonathan; Bucciarelli-Ducci, Chiara; Darzi, Ara; Athanasiou, Thanos

    2013-01-01

    Objectives To compare H index scores for healthcare researchers returned by Google Scholar, Web of Science and Scopus databases, and to assess whether a researcher's age, country of institutional affiliation and physician status influences calculations. Subjects and Methods One hundred and ninety-five Nobel laureates in Physiology and Medicine from 1901 to 2009 were considered. Year of first and last publications, total publications and citation counts, and the H index for each laureate were calculated from each database. Cronbach's alpha statistics was used to measure the reliability of H index scores between the databases. Laureate characteristic influence on the H index was analysed using linear regression. Results There was no concordance between the databases when considering the number of publications and citations count per laureate. The H index was the most reliably calculated bibliometric across the three databases (Cronbach's alpha = 0.900). All databases returned significantly higher H index scores for younger laureates (p < 0.0001). Google Scholar and Web of Science returned significantly higher H index for physician laureates (p = 0.025 and p = 0.029, respectively). Country of institutional affiliation did not influence the H index in any database. Conclusion The H index appeared to be the most consistently calculated bibliometric between the databases for Nobel laureates in Physiology and Medicine. Researcher-specific characteristics constituted an important component of objective research assessment. The findings of this study call to question the choice of current and future academic performance databases. PMID:22964880

  15. Beam emittance measurement from CERN thermionic guns

    International Nuclear Information System (INIS)

    Kester, O.; Rao, R.; Rinolfi, L.

    1992-01-01

    In the LEP Injector Linacs (LIL) a thermionic gun provides electron beams with different peak intensities at an energy of 80 keV. The beam emittances were estimated from the EGUN programme. Since the gun is of triode type, the main contribution to the emittance comes from the grid. The simulation programme does not model the real geometry by assuming a cylindrical symmetry, while the grid does not have such symmetry. A Gun Test Facility (GTF), allowing emittance measurements, based on the 3-gradients-method was installed. The experimental results are presented. (author) 6 refs.; 6 figs

  16. Multi-dimensional beam emittance and β-functions

    International Nuclear Information System (INIS)

    Buon, J.

    1993-05-01

    The concept of r.m.s. emittance is extended to the case of several degrees of freedom that are coupled. That multi-dimensional emittance is lower than the product of the emittances attached to each degree of freedom, but is conserved in a linear motion. An envelope-hyperellipsoid is introduced to define the β-functions of the beam envelope. On the contrary of an one-degree of freedom motion, it is emphasized that these envelope functions differ from the amplitude functions of the normal modes of motion as a result of the difference between the Liouville and Lagrange invariants. (author) 4 refs

  17. Alpha low activity determination from limitter isotopes of uranium, thorium ands radium in natural waters

    International Nuclear Information System (INIS)

    Gascon, J.L.; Crespo, M.T.; Acena, M.L.

    1989-01-01

    A method to concentrate uranium, thorium and radium in natural waters has been developed. The method, based on the adsorbing propert-ies of manganes dioxide, has been applied to determine the alpha emitter isotopes of these elements in drinking water of Madrid. In this work we present the description of the method, the analytical procedu-res and the obtained results. (Author)

  18. Calibration techniques for the in vivo measurement of alpha-emitting actinides

    International Nuclear Information System (INIS)

    Fleming, R.R.

    1976-01-01

    Reliable interpretation of in vivo measurements for alpha-emitting actinides deposited in the lungs is largely dependent on three factors: correction of observed count rates for background contributions; correction for photon absorption in the body; and accurate calibration of the counting system. Terrestrial and cosmic radiation contributions can be minimized by extensive shielding and good pulse-shape discrimination. Techniques are available to minimize errors inherent in the calibration of an in vivo counting system. Minimum amounts of alpha-emitting actinides detectable in the lungs are primarily affected by the accuracy of two factors: predicted body background due to 137 Cs and 40 K, and estimated photon absorption in chest-wall tissue. A matched pair of 12.5-cm-dia phoswich detectors, purchased from the Harshaw Chemical Company, are used to measure low-energy photons emitted by the radioactive actinides

  19. Beam phase space and emittance

    International Nuclear Information System (INIS)

    Buon, J.

    1992-02-01

    The classical and elementary results for canonical phase space, the Liouville theorem and the beam emittance are reviewed. Then, the importance of phase portraits to obtain a geometrical description of motion is emphasized, with examples in accelerator physics. Finally, a statistical point of view is used to define beam emittance, to study its law of approximate conservation, with three particular examples, and to introduce a beam envelope-ellipse and the β-function, emphasing the statistical features of its properties. (author) 14 refs.; 11 figs

  20. Combustion powered thermophotovoltaic emitter system

    Energy Technology Data Exchange (ETDEWEB)

    McHenry, R.S. [Naval Academy, Annapolis, MD (United States). Naval Architecture, Ocean and Marine Engineering

    1995-07-01

    The US Naval Academy (USNA) has recently completed an engineering design project for a high temperature thermophotovoltaic (TPV) photon emitter. The final apparatus was to be portable, completely self contained, and was to incorporate cycle efficiency optimization such as exhaust stream recuperation. Through computer modeling and prototype experimentation, a methane fueled emitter system was designed from structural ceramic materials to fulfill the high temperature requirements necessary for high system efficiency. This paper outlines the engineering design process, discusses obstacles and solutions encountered, and presents the final design.

  1. [Alpha but not beta-adrenergic stimulation has a positive inotropic effect associated with alkalinization of intracellular pH].

    Science.gov (United States)

    Gambassi, G; Lakatta, E G; Capogrossi, M C

    1991-01-01

    There is increasing evidence that alpha-adrenoceptors also exist in the myocardium and that an increase in force of contraction may be produced by stimulation of these sites. This positive inotropism seems to be dependent either on an increased amount of Ca++ released into the cytosol with each action potential or on increased myofilament responsiveness. In contrast, beta-adrenergic stimulation reduces the sensitivity of the contractile proteins and the positive inotropic effect is due to the activation of L-type calcium channels on the sarcolemma. We used single, isolated, enzymatically dissociated, adult rat ventricular myocytes. Cells were loaded either with the ester derivative of the Ca++ probe Indo-1 or with the intracellular pH probe Snarf-1 and at the same time we measured the contractile parameters and monitored the fluorescence as an index of intracellular calcium concentration or pH value. The single cells (bicarbonate buffer continuously gassed with O2 95%, CO2 5%, Ca++ 1.5 mM, field stimulation 0.5 Hz) were exposed to phenylephrine (50 microM) and nadolol (1 microM). Alpha-adrenergic stimulation increased twitch amplitude (delta ES = 1.93 +/- 0.77, n = 8; p less than 0.05) and showed only a slight increase in Ca++ transient. On the other end, the positive inotropic effect (delta ES = 2.84 +/- 0.86, n = 4; p less than 0.02) obtained with beta-adrenergic stimulation (isoproterenol 50 nM, bicarbonate buffer, Ca++ 0.5 mM, field stimulation 0.2 Hz) was always associated with a large increase in intracellular Ca++ concentration. Isoproterenol did not change intracellular pH (delta pH = 0.006 +/- 0.006, n = 4; NS) while phenylephrine increased it significantly (delta pH = 0.055 +/- 0.011, n = 8; p less than 0.002). Moreover, there was a statistically significant correlation between delta ES and delta pH (R2 = 0.532; p less than 0.05) when phenylephrine was present. This alkalinization as well as the increased contractility was antagonized by treatment with

  2. Tumor necrosis factor alpha and interleukin-1 stimulate bone resorption in vivo as measured by urinary [3H]tetracycline excretion from prelabeled mice

    International Nuclear Information System (INIS)

    Koenig, A.M.; Muehlbauer, R.C.F.; Fleisch, H.

    1988-01-01

    Tumor necrosis factor alpha (TNF-alpha) and interleukin-1 (IL-1) have been shown to stimulate bone resorption in vitro. We have now investigated whether these cytokines also cause a similar action when administered in vivo. This was made possible by the adaptation of a newly developed technique that enables the continual assessment of bone resorption in vivo in mice by measuring urinary excretion of 3 H from [ 3 H]tetracycline-prelabeled animals. Experiments using maneuvers known to influence bone resorption, such as a change in dietary calcium or administration of parathyroid hormone or dichloromethylenebisphosphonate, indicate that the technique is reliable and sensitive in mice. Daily intravenous administration of either recombinant human or recombinant murine TNF-alpha, as well as subcutaneous administration of recombinant human IL-1 alpha, were found to stimulate bone resorption in a dose-dependent manner. The effect was maximal within 2 days. Thus, exogenous TNF-alpha and IL-1 alpha can stimulate bone resorption in vivo, suggesting that these cytokines may also exert a systemic effect on bone

  3. An easy method for the determination of Ra isotopes and actinide alpha emitters from the same water sample

    International Nuclear Information System (INIS)

    Moron, M.C.; Garcia-Tenorio, R.; Garcia-Montano, E.; Garcia-Leon, M.; Madurga, G.

    1986-01-01

    Radium isotopes and actinide α emitters are easily determined from the same water sample. The Ra fraction is obtained by coprecipitation with Ba, while a Fe coprecipitation is used for the actinides. Both fractions are measured with a gas-flow proportional counter. Additionally the isotopic Ra composition is obtained by measuring at two or three different times the α activity from the Ra-fraction. The method is applied to rain water and drinking water samples. (author)

  4. Determination of 210Pb by direct gamma-ray spectrometry, beta counting via 210Bi and alpha-particle spectrometry via 210Po in coal, slag and ash samples from thermal power plant

    International Nuclear Information System (INIS)

    Seslak, Bojan; Vukanac, Ivana; Kandic, Aleksandar; Durasevic, Mirjana; Eric, Milic; Jevremovic, Aleksandar

    2017-01-01

    In order to compare three different techniques and estimate radiological impact, activity concentration of 210 Pb in coal, slag and ash samples from thermal power plant 'Nikola Tesla', Serbia, were measured, and results are presented in this study. Determination of 210 Pb was carried out in three ways: using HPGe gamma spectrometer and via in-growth of 210 Po and 210 Bi by alpha-particle spectrometry and proportional counting, respectively. The results obtained for three different techniques were compared. Statistical analysis and comparison of methods were carried out by combination of Z score and χ 2 statistical tests. Tests results, as well as values of measured activities concentrations obtained by alpha and gamma spectrometry, showed that gamma spectrometry is a valid alternative to time-consuming alpha spectrometry for low level activity measurements of 210 Pb. This remark is also valid even for gamma spectrometers with poor efficiency in low energy region. (author)

  5. Education, Democracy, and Social Discourse: A Contemporary Response to George S. Counts and Boyd H. Bode

    Science.gov (United States)

    Collins, William J.

    2013-01-01

    Education, once known as the "great equalizer," is now being called to task for its tendency to disenfranchise and to legitimate inequality due to its obedience to the tenets of capitalism. Two of the nation's greatest educational thinkers, George S. Counts and Boyd H. Bode provided "instructions" for parents and teachers…

  6. Coupling single emitters to quantum plasmonic circuits

    DEFF Research Database (Denmark)

    Huck, Alexander; Andersen, Ulrik Lund

    2016-01-01

    In recent years, the controlled coupling of single-photon emitters to propagating surface plasmons has been intensely studied, which is fueled by the prospect of a giant photonic nonlinearity on a nanoscaled platform. In this article, we will review the recent progress on coupling single emitters...

  7. Transformation of mouse embryo (C3H 10T1/2) cells by alpha particles

    International Nuclear Information System (INIS)

    Lloyd, E.L.; Gemmell, A.; Henning, C.B.; Gemmell, D.S.; Zabransky, B.J.

    1977-01-01

    Mammalian cells in culture (C3H mouse 10T1/2 cells) have been shown here for the first time to be transformed by alpha irradiation when cells were irradiated with 5.6 MeV alpha particles from a Tandem Van de Graaff machine. Malignant tumors were induced following inoculation of the transformed cells into syngeneic hosts. Unirradiated control cells injected at the same concentration have, so far, failed to produce tumors. The morphology of the transformed foci was remarkably similar to that obtained by x rays and chemicals but different from virally transformed cells. When the cells were seeded at low density in the exponential growth phase, the transformation frequency per surviving cell increased approximately as the cube of the dose and peaked at an alpha particle fluence between 1.5 and 2.5 x 10 7 alpha particles per cm 2 (205 to 342 rads). The frequency of the transformation was found to be greatly dependent on the number of cells per dish irradiated. Irradiation of larger numbers resulted in much lower frequencies of transformation. The maximum transformation frequency observed in nine separate experiments was 4 percent of the surviving cells. At doses greater than 200 rads the transformation frequency per surviving cell remained constant. The present results permit us to conclude that alpha irradiation may, indeed, be able to exert a direct effect on the genome of the cell to produce malignancy without any external immunological or hormonal influences

  8. Theory and measurements of emittance preservation in plasma wakefield acceleration

    Energy Technology Data Exchange (ETDEWEB)

    Frederico, Joel

    2016-12-01

    In this dissertation, we examine the preservation and measurement of emittance in the plasma wakefield acceleration blowout regime. Plasma wakefield acceleration (PWFA) is a revolutionary approach to accelerating charged particles that has been demonstrated to have the potential for gradients orders of magnitude greater than traditional approaches. The application of PWFA to the design of a linear collider will make new high energy physics research possible, but the design parameters must first be shown to be competitive with traditional methods. Emittance preservation is necessary in the design of a linear collider in order to maximize luminosity. We examine the conditions necessary for circular symmetry in the PWFA blowout regime, and demonstrate that current proposals meet these bounds. We also present an application of beam lamentation which describes the process of beam parameter and emittance matching. We show that the emittance growth saturates as a consequence of energy spread in the beam. The initial beam parameters determine the amount of emittance growth, while the contribution of energy spread is negligible. We also present a model for ion motion in the presence of a beam that is much more dense than the plasma. By combining the model of ion motion and emittance growth, we find the emittance growth due to ion motion is minimal in the case of marginal ion motion. In addition, we present a simulation that validates the ion motion model, which is under further development to examine emittance growth of both marginal and pronounced ion motion. Finally, we present a proof-of-concept of an emittance measurement which may enable the analysis of emittance preservation in future PWFA experiments.

  9. Energy response of detectors to alpha/beta particles and compatibility of the equivalent factors

    International Nuclear Information System (INIS)

    Lin Bingxing; Li Guangxian; Lin Lixiong

    2011-01-01

    By measuring detect efficiency and equivalent factors of alpha/beta radiation with different energies on three types of detectors, this paper compares compatibility of their equivalent factors and discusses applicability of detectors to measuring total alpha/beta radiation. The result shows the relationship between efficiency of alpha/beta radiation and their energies on 3 types of detectors, such as scintillation and proportional and semiconductor counters, are overall identical. Alpha count efficiency display exponential relation with alpha-particle energy. While beta count efficiency display logarithm relation with beta-particle energy, but the curves appears deflection at low energy. Comparison test of energy response also shows that alpha and beta equivalent factors of scintillation and proportional counters have a good compatibility, and alpha equivalent factors of the semiconductor counters are in good agreement with those of the above two types of counters, but beta equivalent factors have obvious difference, or equivalent factors of low energy beta-particle are lower than those of other detectors. So, the semiconductor counter can not be used for measuring total radioactivity or for the measurements for the purpose of food safety. (authors)

  10. Measurement of transverse emittance in the Fermilab booster

    Energy Technology Data Exchange (ETDEWEB)

    Graves, William Sproull [Wisconsin U., Madison

    1994-01-01

    A new beam profile monitor has been built and installed in the Fermilab Booster synchrotron. It nondestructively measures the beam's vertical density distribution on a fast turn-by-turn basis. This enables one to measure the beam's transverse emittance and to observe emittance growth as it occurs. For high intensities (>2 times 10^{12 } protons), the normalized 95% emittance was observed to grow from 6pi mm-mrad at injection to 16pi mm-mrad at extraction. The initial (<5 msec) emittance growth and beam losses are shown to be caused by the space charge tune shift onto integer and 1/2 integer resonance lines. The growth near injection accounts for approximately 40% of the observed emittance increase throughout the acceleration cycle. The remaining 60% is due to two factors: slow linear growth due to betatron-motion driven by noise in the rf system; and faster growth after the transition energy that is caused by coupling of the longitudinal beam motion into the transverse planes.

  11. Criticality management organization in the alpha incinerator

    International Nuclear Information System (INIS)

    Devillard, D.; Thiebaut, C.; Poinso, J.Y.; Huin, M.

    2004-01-01

    The Valduc Research Center, which reports to the CEA's Military applications Division, generates solid wastes contaminated with alpha emitters in the operation of its installations. An incineration plant has been built to treat these contaminated wastes. Criticality risk prevention is based on limiting the mass of active material undergoing treatment in the facility. A balance is compiled continuously by calculating the difference between the mass of active material entering the facility and the mass leaving it. Due to measurement uncertainties, the balance must be zeroed periodically by cleaning and drainage of all the equipment and the absence of holdup in the components must be checked. (authors)

  12. The microwave and H-alpha sources of the 1992 January 13 flare

    Science.gov (United States)

    Wang, H.; Gary, D. E.; Zirin, H.; Kosugi, T.; Schwartz, R. A.; Linford, G.

    1995-01-01

    We compare X-ray, microwave and H-alpha observations for the 1992 January 13 limb flare. The soft and hard X-ray images of the flare have been studied thoroughly by Masuda et al. (1994) with Yohkoh SXT and HXT images. We find that during the hard X-ray emission peak there is no H-alpha brightening on the disk nor at the limb, so the main ribbons of this flare must be beyond the limb. The microwave source maintains a fixed distance about 10 arcsecs from the optical limb in the frequency range 2.8-14.0 GHz. We interpret this limit in source position as due to the presence of a microwave limb that extends higher than the white-light limb -- to a height of 7300 +/- 1500 km. We believe that the high-frequency microwave emissions are occulted by this extended limb, while the soft and hard X-ray emissions are able to pass through largely unaffected. We also believe, however, that the hard X-ray footpoints are also partially occulted by the photospheric limb, despite the appearance of 'footpoint sources' in HXT data shown by Masuda et al. The smooth X-ray and microwave time profiles, microwave-rich emission relative to hard X-rays, and progressive hard X-ray spectral hardening through the flare peak are all characteristics that we interpret as being a direct result of the occultation of footpoint emission.

  13. Determination of the thoron daughter working level by a one gross alpha-count

    International Nuclear Information System (INIS)

    Bigu, J.; Lau, W.K.

    1983-02-01

    A study has been done on the determination of the thoron daughter Working Level, WL(Tn), by a one gross α-count. The relationship between the gross α-count rate per unit of volume of air sampled and WL(Tn), denoted the F-factor, has been investigated as a function of sampling time, elapsed time from the end of the sampling period, i.e., waiting time, and the thoron daughter disequilibrium ratio [ThC]/[ThB]. It has been found that F depends on both the waiting time and [ThC]/[ThB]. If α-count measurements are made at least 300 min after the end of sampling, F changes by less than 10 percent over the full range of theoretical values of [ThC]/[ThB], i.e., from 0 to 1. The F-factor is independent of [ThC]/[ThB] at approximately 215 min after the end of sampling. This feature can be used to determine WL(Tn) with higher accuracy and at least 1.5 hr earlier than is commonly done using other one gross α-count methods reported in the literature

  14. Development of gas ionization chambers with coplanar electrodes for alpha-ray spectrometry

    International Nuclear Information System (INIS)

    Iwasaki, Kenta; Tanaka, Naomichi; Murakami, Kohei; Hasebe, Nobuyuki; Kusano, Hiroki; Shibamura, Eido; Miyajima, Mitsuhiro

    2016-01-01

    A large-area alpha-ray spectrometer is required to measure the low level alpha emitters in environmental samples, which may be distributed in the vicinity of nuclear power plants. A gas ionization chamber with a coplanar electrode has attractive features such as with mechanical ruggedness, easy handling, easy fabrication of large electrode, and relatively well-known performance. We have investigated the performance of a gas ionization chamber with a coplanar electrode for alpha-ray spectrometry, particularly in the energy resolution. The present experiment shows that the energy resolution in the full width at half maximum (FWHM) is 129 keV (= 2.7%) for alpha-rays from Np with an energy of 4.78 MeV, 120 keV (= 2.2%) for those with 5.49 MeV from Am, and 109 keV (= 1.9%) for those with 5.81 MeV from Cm. It is found that the energy resolution obtained at the present experiment is dominated in the electronic noise caused by the large capacitance existed between the collecting anode (CA) and non-collecting anode (NCA) in the coplanar electrode. (author)

  15. Some rules to improve the energy resolution in alpha liquid scintillation with beta rejection

    CERN Document Server

    Aupiais, J; Dacheux, N

    2003-01-01

    Two common scintillating mixtures dedicated to alpha measurements by means of alpha liquid scintillation with pulse shape discrimination were tested: the di-isopropylnaphthalene - based and the toluene-based solvents containing the commercial cocktails Ultima Gold AB trademark and Alphaex trademark. We show the possibility to enhance the resolution up to 200% by using no-water miscible cocktails and by reducing the optical path. Under these conditions, the resolution of about 200 keV can be obtained either by the Tri Carb sup T sup M or by the Perals sup T sup M spectrometers. The time responses, e.g., the time required for a complete energy transfer between the initial interaction alpha particle-solvent and the final fluorescence of the organic scintillator, have been compared. Both cocktails present similar behavior. According to the Foerster theory, about 6-10 ns are required to complete the energy transfer. For both apparatus, the detection limits were determined for alpha emitters. The sensitivity of the...

  16. Electromagnetic compatibility of implantable neurostimulators to RFID emitters.

    Science.gov (United States)

    Pantchenko, Oxana S; Seidman, Seth J; Guag, Joshua W; Witters, Donald M; Sponberg, Curt L

    2011-06-09

    The objective of this study is to investigate electromagnetic compatibility (EMC) of implantable neurostimulators with the emissions from radio frequency identification (RFID) emitters. Six active implantable neurostimulators with lead systems were tested for susceptibility to electromagnetic fields generated by 22 RFID emitters. These medical devices have been approved for marketing in the U.S. for a number of intended uses that include: epilepsy, depression, incontinence, Parkinsonian tremor and pain relief. Each RFID emitter had one of the following carrier frequencies: 125 kHz, 134 kHz, 13.56 MHz, 433 MHz, 915 MHz and 2.45 GHz. The test results showed the output of one of the implantable neurostimulators was inhibited by 134 kHz RFID emitter at separation distances of 10 cm or less. The output of the same implantable neurostimulator was also inhibited by another 134 kHz RFID emitter at separation distances of 10 cm or less and also showed inconsistent pulsing rate at a separation distance of 15 cm. Both effects occurred during and lasted through out the duration of the exposure. The clinical significance of the effects was assessed by a clinician at the U.S. Food and Drug Administration. The effects were determined to be clinically significant only if they occurred for extended period of time. There were no observed effects from the other 5 implantable neurostimulators or during exposures from other RFID emitters.

  17. Synthesis and antimicrobial evaluation of new 3-alkyl/aryl-2-[((alpha,alpha-diphenyl-alpha-hydroxy)acetyl)hydrazono]-5-methyl-4-thiazolidinones.

    Science.gov (United States)

    Güzeldemirci, Nuray Ulusoy; Ilhan, Eser; Küçükbasmaci, Omer; Satana, Dilek

    2010-01-01

    New 4-thiazolidinone derivatives of benzilic acid (alpha,alpha-diphenyl-alpha-hydroxyacetic acid) have been synthesized and evaluated for antibacterial and antifungal activities. The reaction of 1- (alpha,alpha-diphenyl-alpha-hydroxy)acetyl-4-alkyl/arylthiosemicarbazides with ethyl 2-bromopropionate gave 3-alkyl/aryl-2-[((alpha,alpha-diphenyl-alpha-hydroxy)acetyl)hydrazono]-5-methyl-4-thiazolidinone derivatives. Their antibacterial and antifungal activities were evaluated against S. aureus ATCC 29213, P. aeruginosa ATCC 27853, E. coli ATCC 25922, C. albicans ATCC 10231, C. parapsilosis ATCC 22019, C. krusei ATCC 6258, T. mentagrophytes var. erinacei NCPF 375, M. gypseum NCPF 580 and T. tonsurans NCPF 245. 3e, 3f, 3g and 3h showed the highest antibacterial activity. Particularly 3a and 3e showed the highest antifungal activities against C. parapsilosis ATCC 22019, T. tonsurans NCPF 245 and M. gypseum NCPF 580.

  18. Spherical proton emitters

    International Nuclear Information System (INIS)

    Berg, S.; Semmes, P.B.; Nazarewicz, W.

    1997-01-01

    Various theoretical approaches to proton emission from spherical nuclei are investigated, and it is found that all the methods employed give very similar results. The calculated decay widths are found to be qualitatively insensitive to the parameters of the proton-nucleus potential, i.e., changing the potential parameters over a fairly large range typically changes the decay width by no more than a factor of ∼3. Proton half-lives of observed heavy proton emitters are, in general, well reproduced by spherical calculations with the spectroscopic factors calculated in the independent quasiparticle approximation. The quantitative agreement with experimental data obtained in our study requires that the parameters of the proton-nucleus potential be chosen carefully. It also suggests that deformed proton emitters will provide invaluable spectroscopic information on the angular momentum decomposition of single-proton orbitals in deformed nuclei. copyright 1997 The American Physical Society

  19. Liquid scintillation alpha particle spectrometry. Progress report

    International Nuclear Information System (INIS)

    Bell, L.L.; Hakooz, S.A.; Johnson, L.O.; Nieschmidt, E.B.; Meikrantz, D.H.

    1979-12-01

    Objective to develop a technique whereby Pu may be put into solution, extracted by solvent extraction into a suitable extractive scintillant and subsequently counted. Presented here are results of attempts to separate beta and alpha activities through pulse shape discrimination. A qualitative discussion is given which yields alpha particle peak widths, resolution and response. The detection efficiency for alpha particles in a liquid scintillant is 100%. Present detection sensitivities of the equipment being used are: 4.5 x 10 -6 μCi (100 s), 1.2 x 10 -6 μCi (1000 s), and 4.0 x 10 -7 μCi (10,000 s) at the 3 sigma level. The detectability of a particular alpha-emitting species is strongly dependent upon the population of other species. The ability to discriminate depends upon the system resolution. 14 figures, 2 tables

  20. Determination of natural alpha-emitting isotopes of uranium and thorium in environmental and geological samples

    International Nuclear Information System (INIS)

    Crespo, M.T.

    1996-01-01

    It is described the complete radiochemical procedure used for the determination of uranium and thorium isotopes in environmental and geological samples by alpha spectrometry. Source preparation methods, alpha-counting and spectral analysis are also included