WorldWideScience

Sample records for guyana shield based

  1. Stratigraphy of the Roraima Supergroup along the Brazil-Guyana border in the Guiana shield, Northern Amazonian Craton - results of the Brazil-Guyana Geology and Geodiversity Mapping Project

    Directory of Open Access Journals (Sweden)

    Nelson Joaquim Reis

    Full Text Available ABSTRACT: The Geological and Geodiversity Mapping binational program along the Brazil-Guyana border zone allowed reviewing and integrating the stratigraphy and nomenclature of the Roraima Supergroup along the Pakaraima Sedimentary Block present in northeastern Brazil and western Guyana. The area mapped corresponds to a buffer zone of approximately 25 km in width on both sides of the border, of a region extending along the Maú-Ireng River between Mount Roraima (the triple-border region and Mutum Village in Brazil and Monkey Mountain in Guyana. The south border of the Roraima basin is overlain exclusively by effusive and volcaniclastic rocks of the Surumu Group of Brazil and its correlated equivalent the Burro-Burro Group of Guyana.

  2. Amphibians and Reptiles from Paramakatoi and Kato, Guyana

    Science.gov (United States)

    MacCulloch, Ross D.; Reynolds, Robert P.

    2012-01-01

    We report the herpetofauna of two neighboring upland locations in west-central Guyana. Twenty amphibian and 24 reptile species were collected. Only 40% of amphibians and 12.5% of reptiles were collected in both locations. This is one of the few collections made at upland (750–800 m) locations in the Guiana Shield.

  3. Suicide in Guyana: Nurses' Perspectives.

    Science.gov (United States)

    Anthony, Maureen; Groh, Carla; Gash, Jean

    Guyana, an English-speaking country on the north coast of South America, has the highest suicide rate in the world. Nurses are an integral part of the healthcare team working with patients experiencing psychological distress and are uniquely qualified to add to the discourse on factors contributing to the high suicide rate in Guyana. The purpose of this study was to explore the attitudes and experiences of nurses and nurse assistants in Guyana related to suicide. Nine registered nurses and nurse assistants who worked at a private hospital in Georgetown, Guyana, were recruited to participate in a focus group. The focus group lasted approximately 70 minutes and was recorded. The audio recordings were later transcribed word for word. Four themes emerged from the data: family issues as they relate to the high suicide rate, suicide attempts as a cry for help, lack of support, and coping mechanisms used by nurses when caring for victims of attempted suicide. Nurses are uniquely positioned to intervene with families in crisis, whether it be suicide, suicide attempts, or the underlying factors of family dysfunction, child maltreatment, poverty, or alcoholism. Establishing forensic nursing as a specialty in Guyana would validate this important role through education and certification of nurses.

  4. Identification and Classification of Earthworm Species in Guyana

    OpenAIRE

    Preeta Saywack; Abdullah Adil Ansari

    2011-01-01

    Earthworms are very important organisms, they are both environmentally and economically beneficial and hence their correct identification and classification is very vital. Taxonomy aims to classify organisms based on their similarities and differences. The present study was carried out during the year 2006-2007 at University of Guyana, Georgetown focusing on identification and classification of local earthworm species of Guyana and comparison with a known non-native species (California red). ...

  5. National Scale Monitoring Reporting and Verification of Deforestation and Forest Degradation in Guyana

    Science.gov (United States)

    Bholanath, P.; Cort, K.

    2015-04-01

    Monitoring deforestation and forest degradation at national scale has been identified as a national priority under Guyana's REDD+ Programme. Based on Guyana's MRV (Monitoring Reporting and Verification) System Roadmap developed in 2009, Guyana sought to establish a comprehensive, national system to monitor, report and verify forest carbon emissions resulting from deforestation and forest degradation in Guyana. To date, four national annual assessments have been conducted: 2010, 2011, 2012 and 2013. Monitoring of forest change in 2010 was completed with medium resolution imagery, mainly Landsat 5. In 2011, assessment was conducted using a combination of Landsat (5 and 7) and for the first time, 5m high resolution imagery, with RapidEye coverage for approximately half of Guyana where majority of land use changes were taking place. Forest change in 2013 was determined using high resolution imagery for the whole of Guyana. The current method is an automated-assisted process of careful systematic manual interpretation of satellite imagery to identify deforestation based on different drivers of change. The minimum mapping unit (MMU) for deforestation is 1 ha (Guyana's forest definition) and a country-specific definition of 0.25 ha for degradation. The total forested area of Guyana is estimated as 18.39 million hectares (ha). In 2012 as planned, Guyana's forest area was reevaluated using RapidEye 5 m imagery. Deforestation in 2013 is estimated at 12 733 ha which equates to a total deforestation rate of 0.068%. Significant progress was made in 2012 and 2013, in mapping forest degradation. The area of forest degradation as measured by interpretation of 5 m RapidEye satellite imagery in 2013 was 4 352 ha. All results are subject to accuracy assessment and independent third party verification.

  6. Geological evolution of the center-southern portion of the Guyana shield based on the geochemical, geochronological and isotopic studies of paleoproterozoic granitoids from southeastern Roraima, Brazil

    International Nuclear Information System (INIS)

    Almeida, Marcelo Esteves

    2006-01-01

    This study focuses the granitoids of center-southern portion of Guyana Shield, southeastern Roraima, Brazil. The region is characterized by two tectonic-stratigraphic domains, named as Central Guyana (GCD) and Uatuma-Anaua (UAD) and located probably in the limits of geochronological provinces (e.g. Ventuari-Tapajos or Tapajos-Parima, Central Amazonian and Maroni-Itacaiunas or Transamazon). The aim this doctoral thesis is to provide new petrological and lithostratigraphic constraints on the granitoid rocks and contribute to a better understanding of the origin and geo dynamic evolution of Guyana Shield. The GCD is only locally studied near to the UAD boundary, and new geological data and two single zircon Pb-evaporation ages in mylonitic biotite granodiorite (1.89 Ga) and foliated hastingsite-biotite granite (1.72 Ga) are presented. These ages of the protholiths contrast with the lithostratigraphic picture in the other areas of Cd (1.96-1.93 Ga). Regional mapping, petrography, geochemistry and zircon geochronology carried out in the Urad have showed widespread Paleoproterozoic calc-alkaline granitic magmatism. These granitoid rocks are distributed into several magmatic associations with different Paleoproterozoic (1.97-1.89 Ga) ages, structural and geochemical affinities. Detailed mapping, petrographic and geochronological studies have distinguished two main sub domains in the UAD. In the northern UAD, the high-K calc-alkaline Martins Pereira (1.97 Ga) and Serra Dourada S-type granites (1.96 Ga) are affected by NE-SW and E-W ductile dextral shear-zones, showing coexistence of magmatic and deformational fabrics related to heterogeneous deformation. Inliers of basement (2.03 Ga) crop out northeast of this area, and are formed by meta volcano-sedimentary sequence (Cauarane Group) and TTG-like calc-alkaline association (Anaua Complex). Xenoliths of meta diorites (Anaua Complex) and para gneisses (Cauarane Group) reinforce the intrusive character of Martins Pereira

  7. Preliminary checklist of amphibians and reptiles from Baramita, Guyana

    Science.gov (United States)

    Reynolds, R.P.; MacCulloch, R.D.

    2012-01-01

    We provide an initial checklist of the herpetofauna of Baramita, a lowland rainforest site in the Northwest Region of Guyana. Twenty-five amphibian and 28 reptile species were collected during two separate dry-season visits. New country records for two species of snakes are documented, contributing to the knowledge on the incompletely known herpetofauna of Guyana.

  8. Zircon U-Pb ages of Guyana greenstone-gneiss terrane

    Energy Technology Data Exchange (ETDEWEB)

    Gibbs, A.K. (Cornell Univ., Ithaca, NY (USA)); Olszewski, W.J. Jr. (New Hampshire Univ., Durham (USA))

    1982-04-01

    Isotopic U-Pb studies of zircons collected from weathered metagreywackes of the Barama-Mazaruni Supergroup of northern Guyana, South America, demonstrate an age of origin of ca. 2250 Ma. This is the best estimate for the age of the associated metavolcanic rocks. Zircons from weathered gneiss of the Bartica complex, adjacent to the volcanic-sedimentary belts, yield a similar age. The contiguous greenstone-gneiss terrane of eastern Venezuela is also of similar age and comparable greenstone-gneiss terranes of eastern Suriname and French Guiana are probably also of this age. Continental crust formation of a style closely comparable to that of the Canadian Archean occurred on a very widespread scale in the Lower Proterozoic of the Guiana shield. The lead losses from the weathered zircons are comparable to those from zircons from fresh rock from the adjacent terrane of Venezuela, and the advantages of field concentration from numerous saprolite exposures warrant use of such material in future geochronological studies of the region.

  9. Non-timber forest products of the North-West District of Guyana

    NARCIS (Netherlands)

    Andel, T.R. van

    2000-01-01

    This thesis describes the use of non-timber forest products (NTFPs) by indigenous peoples of northwest Guyana. Part I contains a general analysis of NTFP harvesting in northwest Guyana Part II is an illustrated field guide of the useful plants encountered. Chapter 1: introduction Chapter

  10. Technology Integration in the Schools of Guyana: A Case Study

    Science.gov (United States)

    MacKinnon, Gregory; MacKinnon, Paula

    2010-01-01

    The following study examines the implementation of learning technologies in Guyana, South America. Specifically, the study addresses the impact of using interactive radio instruction for teaching mathematics and SuccessMaker software for enhancing literacy skills. The research results were based on surveys, interviews, classroom observations, and…

  11. Baseline Inventory of amphibians and reptiles of Kurupukari, Guyana

    Science.gov (United States)

    MacCulloch, Ross D.; Reynolds, Robert P.

    2013-01-01

    The habitat in the vicinity of Kurupukari, on the Essequibo River in central Guyana, is tall evergreen lowland forest. The area has suffered some human disturbance from agriculture, road construction and ferry activity. The area was sampled for 10 days in 1990 and 12 days in 1997; seven days in rainy season and 15 in dry season. During this sampling 23 anuran and 17 reptile species were collected. Some differences exist between species collected on either side of the river. Comparisons are made with collections from other locations in Guyana.

  12. Amphibians and reptiles of Guyana, South America: illustrated keys, annotated species accounts, and a biogeographic synopsis

    Science.gov (United States)

    Cole, Charles J.; Townsend, Carol R.; Reynolds, Robert P.; MacCulloch, Ross D.; Lathrop, Amy

    2013-01-01

    Guyana has a very distinctive herpetofauna. In this first ever detailed modern accounting, based on voucher specimens, we document the presence of 324 species of amphibians and reptiles in the country; 148 amphibians, 176 reptiles. Of these, we present species accounts for 317 species and color photographs of about 62% (Plates 1–40). At the rate that new species are being described and distributional records are being found for the first time, we suspect that at least 350 species will be documented in a few decades. The diverse herpetofauna includes 137 species of frogs and toads, 11 caecilians, 4 crocodylians, 4 amphisbaenians, 56 lizards, 97 snakes, and 15 turtles. Endemic species, which occur nowhere else in the world, comprise 15% of the herpetofauna. Most of the endemics are amphibians, comprising 27% of the amphibian fauna. Type localities (where the type specimens or scientific name-bearers of species were found) are located within Guyana for 24% of the herpetofauna, or 36% of the amphibians. This diverse fauna results from the geographic position of Guyana on the Guiana Shield and the isolated highlands or tepuis of the eastern part of the Pantepui Region, which are surrounded by lowland rainforest and savannas. Consequently, there is a mixture of local endemic species and widespread species characteristic of Amazonia and the Guianan Region. Although the size of this volume may mislead some people into thinking that a lot is known about the fauna of Guyana, the work has just begun. Many of the species are known from fewer than five individuals in scientific collections; for many the life history, distribution, ecology, and behavior remain poorly known; few resources in the country are devoted to developing such knowledge; and as far as we are aware, no other group of animals in the fauna of Guyana has been summarized in a volume such as this to document the biological resources. We briefly discuss aspects of biogeography, as reflected in samples collected

  13. Intestinal parasites among young children in the interior of Guyana.

    Science.gov (United States)

    Lindo, J F; Validum, L; Ager, A L; Campa, A; Cuadrado, R R; Cummings, R; Palmer, C J

    2002-03-01

    Intestinal parasites contribute greatly to morbidity in developing countries. While there have been several studies of the problem in the Caribbean, including the implementation of control programmes, this has not been done for Guyana. The aim of this study was to determine the prevalence of intestinal parasites among young children in a town located in the interior of Guyana. Eighty-five children under the age of 12 years were studied prospectively for intestinal parasites in Mahdia, Guyana. Stool samples were transported in formalin to the Department of Microbiology, The University of the West Indies, Jamaica, for analysis using the formalin-ether concentration and Ziehl-Neelsen techniques. Data on age and gender of the children were recorded on field data sheets. At least one intestinal parasite was detected in 43.5% (37/85) of the children studied and multiple parasitic infections were recorded in 21.2% (18/85). The most common intestinal helminth parasite was hookworm (28.2%; 24/85), followed by Ascaris lumbricoides (18.8%; 16/85) and then Trichuris trichuria (14.1%; 12/85). Among the protozoan infections Giardia lamblia was detected in 10.5% (9/85) of the study population while Entamoeba histolytica appeared rarely. All stool samples were negative for Cryptosporidium and other intestinal Coccidia. There was no predilection for gender with any of the parasites. The pattern of distribution of worms in this area of Guyana was unlike that seen in other studies. Hookworm infection was the most common among the children and a large proportion had multiple infections. The study established the occurrence and prevalence of a number of intestinal parasites in the population of Guyana. This sets the stage for the design and implementation of more detailed epidemiological studies.

  14. Re-democratization in Guyana and Suriname: Critical Comparisons

    Directory of Open Access Journals (Sweden)

    Chaitram Singh

    2008-04-01

    Full Text Available Guyana and Suriname both re-assumed the path to  democracy in the early 1990s. Guyana had from  1968 to 1992 experienced an authoritarian regime  with the People’s National Congress (PNC, led by  Forbes Burnham, maintaining power by rigged  elections and the support of the security forces. In  Suriname, on the other hand, the elected government of Prime Minister Henck Arron was overthrown by a military coup in 1980. This article traces  the establishment of authoritarianism in these two  countries and examines the factors which propelled  each country towards the restoration of democracy.  The central argument is that authoritarianism in  Guyana resulted from the success of Forbes Burnham in subordinating the military to party rule  while the military take-over in Suriname resulted  from the mismanagement of civil-military relations  by the government of Henck Arron. However,  maintaining an authoritarian regime proved costly  in both cases. The need for external aid rendered  the regimes susceptible to foreign pressure for a  return to free and fair elections. All of this occurred  in a new hemispheric context shaped by the end of  the Cold War, the stated goal of the United States  to have the area become a zone of democracy, and  impending foreign military intervention to restore  the ousted Aristide government to power in Haiti. Resumen: Redemocratización en Guyana y Suriname: Comparaciones CríticasTanto Guyana como Suriname retomaron el  camino hacia la democracia a comienzos de la  década de los noventa. Desde 1968 hasta 1992,  Guyana tuvo un régimen autoritario con el Congreso Nacional del Pueblo (People’s National  Congress o PNC, liderado por Forbes Burnham,  que se mantuvo en el poder gracias a la manipulación de las elecciones y al apoyo de las fuerzas  de seguridad. En Suriname, por otro lado, el  gobierno electo del primer ministro Henck Arron  fue derrocado por un golpe de estado militar en

  15. Non-timber forest products of the North-West District of Guyana

    OpenAIRE

    Andel, T.R. van

    2000-01-01

    This thesis describes the use of non-timber forest products (NTFPs) by indigenous peoples of northwest Guyana. Part I contains a general analysis of NTFP harvesting in northwest Guyana Part II is an illustrated field guide of the useful plants encountered. Chapter 1: introduction Chapter 2: floristic composition and vegetation structure of well-drained mixed forest and 20- and 60-year old secondary forests. Previous forest inventories predicted a general low diversity for the North-West Distr...

  16. The grasses (Poaceae) of the Colombian Guyana: analyses on their composition, richness, endemism, and invasion

    International Nuclear Information System (INIS)

    Giraldo Canas, Diego

    2010-01-01

    The checklist of grasses from Colombian Guyana is presented. In all, 152 species, 69 genera, and six subfamilies were recorded. Thus, in the Colombian Guyana is represented the 18.7 and 43.7% of the species and genera of Colombian grasses, respectively. The subfamilies with the highest number of species were Panicoideae (110 species/46 genera), Chloridoideae (21/9), and Bambusoideae (11/9). The most diverse genera were Paspalum (19 species), Panicum (16), Axonopus (14), Eragrostis (9), and Digitaria (8). Nineteen species are introduced and naturalized in the Colombian Guyana, which represent 12.5% of the agrostological flora for the Colombian Guyana. There were 8 endemic species (5.3% of Colombian Guayanan grasses). In addition, some species are reported for the first time for Colombian flora (belonging to Axonopus, Cyphonanthus, Gymnopogon, and Paspalum), and some species are new to science (belonging to Axonopus, Digitaria, Eragrostis, and Sacciolepis). On the other hand, some preliminary biogeographical aspect are analyzed.

  17. Two new combinations in Euploca Nutt. (Heliotropiaceae, Boraginales) and a conspectus of the species of the Guiana Shield area

    Science.gov (United States)

    Feuillet, Christian

    2016-01-01

    Abstract Heliotropium foliatum and Tournefortia humilis are transferred to Euploca Nutt. respectively as Euploca foliata comb. n. and Euploca humilis comb. n. A collection from Guyana has been recently identified as Euploca humistrata, a species previously considered a Brazilian endemic. A collection from French Guiana documents for the first time the species in that country. A key to the species of the Guiana Shield area is given. The species of Euploca from the Guiana Shield are listed with synonymy and a brief description: Euploca filiformis, Euploca humilis, Euploca humistrata, Euploca lagoensis, Euploca polyphylla, Euploca procumbens. PMID:27081354

  18. DNA barcoding reveals the diversity of sharks in Guyana coastal markets

    Directory of Open Access Journals (Sweden)

    Matthew A. Kolmann

    2017-12-01

    Full Text Available ABSTRACT A fundamental challenge for both sustainable fisheries and biodiversity protection in the Neotropics is the accurate determination of species identity. The biodiversity of the coastal sharks of Guyana is poorly understood, but these species are subject to both artisanal fishing as well as harvesting by industrialized offshore fleets. To determine what species of sharks are frequently caught and consumed along the coastline of Guyana, we used DNA barcoding to identify market specimens. We sequenced the mitochondrial co1 gene for 132 samples collected from six markets, and compared our sequences to those available in the Barcode of Life Database (BOLD and GenBank. Nearly 30% of the total sample diversity was represented by two species of Hammerhead Sharks (Sphyrna mokarran and S. lewini, both listed as Endangered by the International Union for Conservation of Nature (IUCN. Other significant portions of the samples included Sharpnose Sharks (23% - Rhizoprionodon spp., considered Vulnerable in Brazilian waters due to unregulated gillnet fisheries, and the Smalltail Shark (17% - Carcharhinus porosus. We found that barcoding provides efficient and accurate identification of market specimens in Guyana, making this study the first in over thirty years to address Guyana’s coastal shark biodiversity.

  19. Long-term responses of populations and communities of trees to selective logging in tropical rain forests in Guyana

    NARCIS (Netherlands)

    Arets, E.J.M.M. (Eric Jacobus Monica Maria)

    2005-01-01

    Since only a small area of Guyana's forest can be effectively protected and because timber harvesting is an important source of income, logged forests will play an important role in the conservation of biodiversity in Guyana. Selective logging, in which only a few trees per hectare are harvested and

  20. Aspectos do Desenvolvimento Político e Econômico da Guyana

    Directory of Open Access Journals (Sweden)

    Iuri Cavlak

    2014-07-01

    Full Text Available Este artigo visa analisar alguns aspectos do desenvolvimento político e econômico da Guyana, pequeno país sul-americano situado no extremo norte do subcontinente. Tendo seu passado ligado a Holanda e a Inglaterra, a Guyana só conquistou sua independência em 1966, num contexto de avanço dos movimentos sociais, empolgados na construção de uma nova nação, e oposição dos Estados Unidos, tentando frear a difusão das ideias socialistas e o apego da política externa guianense ao bloco soviético. A busca por uma economia nacionalizada e planejada foi constante, embora com resultados deveras aquém do esperado.

  1. The Diverse Uses Of Fish-Poison Plants In Northwest Guyana

    NARCIS (Netherlands)

    Andel, T.R. van

    2000-01-01

    Although prohibited by law, fish poison plants are still widely used by indigenous tribes in Guyana. The latest ethnobotanical collections date from the first half of the 20th century and, from recent anthropological studies, it cannot be deduced whether the same species are still used today. The

  2. Geological evolution of the center-southern portion of the Guyana shield based on the geochemical, geochronological and isotopic studies of paleoproterozoic granitoids from southeastern Roraima, Brazil; Evolucao geologica da porcao centro-sul do escudo das Guianas com base no estudo geoquimico, geocronologico e isotopico dos granitoides paleoproterozoicos do sudeste de Roraima, Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Marcelo Esteves

    2006-07-01

    This study focuses the granitoids of center-southern portion of Guyana Shield, southeastern Roraima, Brazil. The region is characterized by two tectonic-stratigraphic domains, named as Central Guyana (GCD) and Uatuma-Anaua (UAD) and located probably in the limits of geochronological provinces (e.g. Ventuari-Tapajos or Tapajos-Parima, Central Amazonian and Maroni-Itacaiunas or Transamazon). The aim this doctoral thesis is to provide new petrological and lithostratigraphic constraints on the granitoid rocks and contribute to a better understanding of the origin and geo dynamic evolution of Guyana Shield. The GCD is only locally studied near to the UAD boundary, and new geological data and two single zircon Pb-evaporation ages in mylonitic biotite granodiorite (1.89 Ga) and foliated hastingsite-biotite granite (1.72 Ga) are presented. These ages of the protholiths contrast with the lithostratigraphic picture in the other areas of Cd (1.96-1.93 Ga). Regional mapping, petrography, geochemistry and zircon geochronology carried out in the Urad have showed widespread Paleoproterozoic calc-alkaline granitic magmatism. These granitoid rocks are distributed into several magmatic associations with different Paleoproterozoic (1.97-1.89 Ga) ages, structural and geochemical affinities. Detailed mapping, petrographic and geochronological studies have distinguished two main sub domains in the UAD. In the northern UAD, the high-K calc-alkaline Martins Pereira (1.97 Ga) and Serra Dourada S-type granites (1.96 Ga) are affected by NE-SW and E-W ductile dextral shear-zones, showing coexistence of magmatic and deformational fabrics related to heterogeneous deformation. Inliers of basement (2.03 Ga) crop out northeast of this area, and are formed by meta volcano-sedimentary sequence (Cauarane Group) and TTG-like calc-alkaline association (Anaua Complex). Xenoliths of meta diorites (Anaua Complex) and para gneisses (Cauarane Group) reinforce the intrusive character of Martins Pereira

  3. Seroprevalence of Trypanosoma cruzi in blood donors at the National Blood Transfusion Services--Guyana.

    Science.gov (United States)

    Bwititi, P T; Browne, J

    2012-09-01

    Blood transfusion is an important transmission route of Trypanosoma cruzi (T cruzi), a major parasitic infection in Central and South America. The limited treatment options are most effective in acute Chagas' infection. At present, there is no current data on the prevalence of T cruzi in the blood donor population of Guyana. This information is necessary to protect the supply of the blood donation programme. This study sought to determine the prevalence of T cruzi in the blood supply at the National Blood Transfusion Services of Guyana with the hope of providing knowledge to the on-going surveillance for Chagas' disease worldwide and therefore address the risk of its spread by blood transfusion. Two commercialized ELISAs utilizing crude or recombinant T cruzi antigens were used to study 2000 blood samples voluntarily donated for the purpose of altruistic or family replacement donation retrospectively. The results showed that approximately 1 in 286 donations tested positive for antibodies to T cruzi. These results indicate that T cruzi continues to be a risk in Guyana and there is a need to continue screening donated blood. Trypanosoma cruzi is a life-long infection and infected persons may be asymptomatic chronic carriers of the disease. Education, housing improvement, and controlled use of insecticides should be introduced to contain Chagas' disease.

  4. Decree nr 2017-457 of 30 March 2017 related to Guyana energy multi-year programming

    International Nuclear Information System (INIS)

    Sapin, Michel; Bareigts, Ericka

    2017-01-01

    The decree defines objectives of energy efficiency and reduction of fossil energy consumption, and of development of energy production from renewable energies, addresses issues related to security of supply and to the balance between supply and demand, to access to electric power, and to studies on infrastructures. As appendix, the text of the 2016-2018 and 2019-2023 energy multi-year programming (PPE) for Guyana is provided. This document first presents the Guyana energy system: history and energy assessment for 2014, legal and regulatory framework specific to Guyana, European and international context, power production costs. It analyses the energy demand: past evolution, determining factors of supply evolution, objectives of strengthening energy efficiency measures, objectives of reduction of energy poverty, objectives of reduction of primary fossil energy consumption. The third part addresses objectives of security of supply (for fuel, other fossil energies, and electricity). The next part analyses the energy supply: stakes, quantitative objectives for biomass, waste valorisation, hydraulic and other energy sources, objectives of development of renewable energies. It discusses the issue of connection of inland communes to the network, and issues related to energy infrastructure and networks

  5. A practical neutron shielding design based on data-base interpolation

    International Nuclear Information System (INIS)

    Jiang, S.H.; Sheu, R.J.

    1993-01-01

    Neutron shielding design is an important part of the construction of nuclear reactors and high-energy accelerators. Neutron shielding design is also indispensable in the packaging and storage of isotopic neutron sources. Most efforts in the development of neutron shielding design have been concentrated on nuclear reactor shielding because of its huge mass and strict requirement of accuracy. Sophisticated computational tools, such as transport and Monte Carlo codes and detailed data libraries have been developed. In principle, now, neutron shielding, in spite of its complexity, can be designed in any detail and with fine accuracy. However, in most practical cases, neutron shielding design is accomplished with simplified methods. Unlike practical gamma-ray shielding design, where exponential attenuation coupled with buildup factors has been applied effectively and accurately, simplified neutron shielding design, either by using removal cross sections or by applying charts or tables of transmission factors such as the National Council on Radiation Protection and Measurements (NCRP) 38 (Ref. 1) for general neutron protection or to NCRP 51 (Ref. 2) for accelerator neutron shielding, is still very primitive and not well established. The available data are limited in energy range, materials, and thicknesses, and the estimated results are only roughly accurate. It is the purpose of this work to establish a simple, convenient, and user-friendly general-purpose computational tool for practical preliminary neutron shielding design that is reasonably accurate. A wide-range (energy, material, and thickness) data base of dose transmission factors has been generated by applying one-dimensional transport calculations in slab geometry

  6. Carbon offsets as an economic alternative to large-scale logging: a case study in Guyana

    Energy Technology Data Exchange (ETDEWEB)

    Osborne, T. [Energy and Resources Group, University of California Berkeley, 310 Barrows Hall, Berkeley CA 94720 (United States); Kiker, C. [Food and Resource Economics Department, University of Florida, PO Box 110240, Gainesville, FL 32611 (United States)

    2005-03-01

    The objective of this study is to analyze the economic viability of carbon-offset projects that avoid logging in Guyana's forests. The results of this case study illustrate the cost effectiveness of alternative land-use options that reduce deforestation and associated greenhouse gas (GHG) emissions. This analysis demonstrates that using Guyana's rainforests for climate change mitigation can generate equivalent revenue to that of conventional large-scale logging without detrimental environmental impacts. At a 12% discount rate, the break-even price for carbon is estimated to be about US$ 0.20/tC. This estimate falls toward the low range of carbon prices for existing carbon offset projects that avoid deforestation.

  7. A new species of broad-nosed bat Platyrrhinus Saussure, 1860 (Chiroptera:   Phyllostomidae) from the Guianan Shield.

    Science.gov (United States)

    Velazco, Paúl M; Lim, Burton K

    2014-05-16

    A new species of broad-nosed bat Platyrrhinus Saussure, 1860 (Chiroptera: Phyllostomidae: Stenodermatinae) from the Guianan Shield is described based on molecular and morphological data. Previously confused with P. helleri and P. recifinus, the new taxon is currently known from only Guyana and Suriname and is most closely related to P. recifinus from eastern Brazil and not to the two sympatric species (P. fusciventris and P. incarum) also recently recognized as distinct from P. helleri. Morphometrically the new taxon overlaps with the smaller species of the genus (P. angustirostris, P. brachycephalus, P. fusciventris, P. helleri, P. incarum, and P. matapalensis), but forms a different cluster from the larger P. recifinus. Morphologically the new taxon is distinguished from its congeners by a combination of external and craniodental characteristics. Platyrrhinus now includes 21 species making it the most speciose genus in the Neotropical family Phyllostomidae.

  8. Assessing forest degradation in Guyana with GeoEye, Quickbird and Landsat

    Science.gov (United States)

    Bobby Braswell; Steve Hagen; William Salas; Michael Palace; Sandra Brown; Felipe Casarim; Nancy Harris

    2013-01-01

    Forest degradation is defined as a change in forest quality and condition (e.g. reduction in biomass), while deforestation is a change in forest area. This pilot study evaluated several image processing approaches to map degradation and estimate carbon removals from logging. From the Joint Concept Note on REDD+ cooperation between Guyana and Norway carbon loss as...

  9. Neutron shielding material based on colemanite and epoxy resin

    International Nuclear Information System (INIS)

    Okuno, K.

    2005-01-01

    In recent years, there has been a need for compact shielding design such as self-shielding of a PET cyclotron or up-gradation of radiation machinery in existing facilities. In these cases, high performance shielding materials are needed. Concrete or polyethylene have been used for a neutron shield. However, for compact shielding, they fall short in terms of performance or durability. Therefore, a new type of neutron shielding material based on epoxy resin and colemanite has been developed. Slab attenuation experiments up to 40 cm for the new shielding material were carried out using a 252 Cf neutron source. Measurement was carried out using a REM-counter, and compared with calculation. The results show that the shielding performance is better than concrete and polyethylene mixed with 10 wt% boron oxide. From the result, we confirmed that the performance of the new material is suitable for practical use. (authors)

  10. Proceedings from a workshop on Sustainable forest management in tropical forests of Guyana

    Energy Technology Data Exchange (ETDEWEB)

    Hagner, Mats [ed.] [Swedish Univ. of Agricultural Sciences, Umeaa (Sweden). Dept. of Silviculture; Maluenda, J. [ed.] [ORGUT Consulting AB, Stockholm (Sweden)

    1998-12-31

    Guyana officials were certain that an efficient forest management could yield economic benefits to the country, while still allowing for the sustainability of its forest resources. Standards will be set in a Code of Practice (COP). Lectures, presented in the proceeding, were mixed with group discussions and finally the 26 participants gave their written view of `What has to be done in Guyana and by whom?`. Amerindians wanted their own foresters should be recruited to oversee the activities on their own land. Bushmilling need to be controlled but not banned. Monitoring timber products and control of hunting should be stricter. COP should set standards for the residual stand. Environmental Protection Agency wanted more research and training, with aim of self-monitoring capability for forest users. Forest Products Association recommended government to co-operate for refinement of: training, mapping of resources, harvesting plans, concession agreements, road building, and bushmilling. Forestry Commission wanted concession allocation procedures to be reviewed: zonation of chainsaw activities, protection of small-scale operators, management plans. COP should be revised and tested in practice. Suggestion about standards for residual stand should be considered. ORGUT Lecturers recommended a standard for residual stand, a vertical and horizontal spot density measure. Based on that the concession holder could harvest what, where and when be preferred and chose the most efficient technique

  11. Proceedings from a workshop on Sustainable forest management in tropical forests of Guyana

    Energy Technology Data Exchange (ETDEWEB)

    Hagner, Mats [ed.; Swedish Univ. of Agricultural Sciences, Umeaa (Sweden). Dept. of Silviculture; Maluenda, J [ed.; ORGUT Consulting AB, Stockholm (Sweden)

    1999-12-31

    Guyana officials were certain that an efficient forest management could yield economic benefits to the country, while still allowing for the sustainability of its forest resources. Standards will be set in a Code of Practice (COP). Lectures, presented in the proceeding, were mixed with group discussions and finally the 26 participants gave their written view of `What has to be done in Guyana and by whom?`. Amerindians wanted their own foresters should be recruited to oversee the activities on their own land. Bushmilling need to be controlled but not banned. Monitoring timber products and control of hunting should be stricter. COP should set standards for the residual stand. Environmental Protection Agency wanted more research and training, with aim of self-monitoring capability for forest users. Forest Products Association recommended government to co-operate for refinement of: training, mapping of resources, harvesting plans, concession agreements, road building, and bushmilling. Forestry Commission wanted concession allocation procedures to be reviewed: zonation of chainsaw activities, protection of small-scale operators, management plans. COP should be revised and tested in practice. Suggestion about standards for residual stand should be considered. ORGUT Lecturers recommended a standard for residual stand, a vertical and horizontal spot density measure. Based on that the concession holder could harvest what, where and when be preferred and chose the most efficient technique

  12. Tungsten-based composite materials for fusion reactor shields

    International Nuclear Information System (INIS)

    Greenspan, E.; Karni, Y.

    1985-01-01

    Composite tungsten-based materials were recently proposed for the heavy constituent of compact fusion reactor shields. These composite materials will enable the incorporation of tungsten - the most efficient nonfissionable inelastic scattering (as well as good neutron absorbing and very good photon attenuating) material - in the shield in a relatively cheap way and without introducing voids (so as to enable minimizing the shield thickness). It is proposed that these goals be achieved by bonding tungsten powder, which is significantly cheaper than high-density tungsten, with a material having the following properties: good shielding ability and relatively low cost and ease of fabrication. The purpose of this work is to study the effectiveness of the composite materials as a function of their composition, and to estimate the economic benefit that might be gained by the use of these materials. Two materials are being considered for the binder: copper, second to tungsten in its shielding ability, and iron (or stainless steel), the common fusion reactor shield heavy constituent

  13. New gadolinium based glasses for gamma-rays shielding materials

    International Nuclear Information System (INIS)

    Kaewjang, S.; Maghanemi, U.; Kothan, S.; Kim, H.J.; Limkitjaroenporn, P.; Kaewkhao, J.

    2014-01-01

    Highlights: • Gd 2 O 3 based glasses have been fabricated and investigated radiation shielding properties between 223 and 662 keV. • Density of the glass increases with increasing of Gd 2 O 3. • All the glasses of Gd 2 O 3 compositions studied had been shown lower HVL than X-rays shielding window. • Prepared glasses to be utilized as radiation shielding material with Pb-free advantage. • This work is the first to reports on radiation shielding properties of Gd 2 O 3 based glass matrices. - Abstract: In this work, Gd 2 O 3 based glasses in compositions (80−x)B 2 O 3 -10SiO 2 -10CaO-xGd 2 O 3 (where x = 15, 20, 25, 30 and 35 mol%) have been fabricated and investigated for their radiation shielding, physical and optical properties. The density of the glass was found to increase with the increasing of Gd 2 O 3 concentration. The experimental values of mass attenuation coefficients (μ m ), effective atomic number (Z eff ) and effective electron densities (N e ) of the glasses were found to increase with the increasing of Gd 2 O 3 concentration and also with the decreasing of photon energy from 223 to 662 keV. The glasses of all Gd 2 O 3 compositions studied have been shown with lower HVL values in comparison to an X-rays shielding window, ordinary concrete and commercial window; indicating their potential as radiation shielding materials with Pb-free advantage. Optical spectra of the glasses in the present study had been shown with light transparency; an advantage when used as radiation shielding materials

  14. Measuring Institutional Trust: Evidence from Guyana

    Directory of Open Access Journals (Sweden)

    Troy Devon Thomas

    2015-01-01

    Full Text Available Institutional trust is often measured by several items that are analyzed individually or as sum-scores. However, it is difficult to summarize the results of individual-items analyses, whereas sum-scores may be meaningless if the dimensions that the items are assumed to measure are not verified. Although these limitations are circumvented by using factor analysis, response styles may still bias research results. We use data from Guyana to show that a second-order factor model is appropriate for measuring institutional trust. We also demonstrate that response styles can inflate item and factor convergent validity and may either distort regression effects or create completely spurious ones. We therefore recommend using factor models with corrections for response styles in institutional trust research instead of sum-scores and individual-items analyses.

  15. Adaptations of lowland jungle mosses to anthropogenic environments in Guyana

    OpenAIRE

    Kuc, Marian

    2000-01-01

    Sixteen lowland jungle mosses growing in anthropogenic habitats at Santa and The Bell - Ituni localities on the Demerara River in Guyana were examined in detail with the aim of detecting any features which would indicate their adaptations to new habitats. Amounts of chlorophyll in leaf cells, protective coloration, alterations in leaf morphology, characteristics of old stems, rhizoid tomentum and fertility are considered as the most pronounced adaptive features of these species to new localit...

  16. New gadolinium based glasses for gamma-rays shielding materials

    Energy Technology Data Exchange (ETDEWEB)

    Kaewjang, S.; Maghanemi, U.; Kothan, S. [Department of Radiologic Technology, Faculty of Associated Medical Sciences, Chang Mai University, Chang Mai 50200 (Thailand); Kim, H.J. [Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Limkitjaroenporn, P. [Center of Excellence in Glass Technology and Materials Science (CEGM), Nakhon Pathom Rajabhat University, Nakhon Pathom 73000 (Thailand); Kaewkhao, J., E-mail: mink110@hotmail.com [Center of Excellence in Glass Technology and Materials Science (CEGM), Nakhon Pathom Rajabhat University, Nakhon Pathom 73000 (Thailand)

    2014-12-15

    Highlights: • Gd{sub 2}O{sub 3} based glasses have been fabricated and investigated radiation shielding properties between 223 and 662 keV. • Density of the glass increases with increasing of Gd{sub 2}O{sub 3.} • All the glasses of Gd{sub 2}O{sub 3} compositions studied had been shown lower HVL than X-rays shielding window. • Prepared glasses to be utilized as radiation shielding material with Pb-free advantage. • This work is the first to reports on radiation shielding properties of Gd{sub 2}O{sub 3} based glass matrices. - Abstract: In this work, Gd{sub 2}O{sub 3} based glasses in compositions (80−x)B{sub 2}O{sub 3}-10SiO{sub 2}-10CaO-xGd{sub 2}O{sub 3} (where x = 15, 20, 25, 30 and 35 mol%) have been fabricated and investigated for their radiation shielding, physical and optical properties. The density of the glass was found to increase with the increasing of Gd{sub 2}O{sub 3} concentration. The experimental values of mass attenuation coefficients (μ{sub m}), effective atomic number (Z{sub eff}) and effective electron densities (N{sub e}) of the glasses were found to increase with the increasing of Gd{sub 2}O{sub 3} concentration and also with the decreasing of photon energy from 223 to 662 keV. The glasses of all Gd{sub 2}O{sub 3} compositions studied have been shown with lower HVL values in comparison to an X-rays shielding window, ordinary concrete and commercial window; indicating their potential as radiation shielding materials with Pb-free advantage. Optical spectra of the glasses in the present study had been shown with light transparency; an advantage when used as radiation shielding materials.

  17. Implementation of a standardized HIV patient monitoring system in Guyana Establecimiento de un sistema estandarizado de vigilancia de los pacientes infectados por el VIH en Guyana

    Directory of Open Access Journals (Sweden)

    Mina Halpern

    2010-08-01

    Full Text Available OBJECTIVE: To describe the process used to implement a comprehensive, standardized, and reliable national system for data collection for HIV care and treatment in Guyana; to provide examples of the program-level data resulting from implementation; and to highlight the monitoring benefits for national programs. METHODS: In 2007, Guyana's Ministry of Health and other key stakeholders adapted the World Health Organization's generic HIV care and antiretroviral therapy (ART patient monitoring guidelines to fit the Guyana context, which included modifying the patient chart, patient registers, and cross-sectional and cohort reports. Following initial training and feedback from clinical staff, a national patient monitoring system (PMS was finalized, piloted, and implemented at all care and treatment sites. Thereafter, sites received monthly supportive supervisory visits to review data collection and validate reports. RESULTS: Implementation of the PMS enabled analysis of cohort data for patients on ART. After 12 months, 79% of a combined national cohort of all 50 patients who started ART in June 2007 were alive and on first-line ART regimens. After six years, 58% of the first (April 2002 cohort of ART patients in the country were alive and on ART, with only two (8% patients on second-line regimens. CONCLUSIONS: Implementation of a national PMS for standardized data collection and reporting across multiple clinical sites ultimately provided important and reliable information on utilization of services, patient outcomes, and survival rates on treatment. These data are used at the national level to monitor the efficacy of the HIV care and treatment program. Successful implementation requires early inclusion of all committed stakeholders and a dedicated human resource team to ensure sustainability of the system.OBJETIVO: Describir el proceso utilizado con el objeto de poner en práctica un sistema nacional integral, estandarizado y confiable de recopilaci

  18. Gilles de la Tourette Syndrome—A Case Report from Guyana in South America

    Directory of Open Access Journals (Sweden)

    V. Eapen

    1992-01-01

    Full Text Available A case of the Gilles de la Tourette syndrome from Guyana in South America is presented. The patient had a positive family history as well as coprolalia, echolalia, and attention deficit disorder with hyperactivity. The family history and cross-cultural similarity emphasise the biological factors in the aetiology of the syndrome.

  19. Gamma ray shielding: a web based interactive program

    International Nuclear Information System (INIS)

    Subbaiah, K.V.; Senthi Kumar, C.; Sarangapani, R.

    2005-01-01

    A web based interactive computing program is developed using java for quick assessment of Gamma Ray shielding problems. The program addresses usually encountered source geometries like POINT, LINE, CYLINDRICAL, ANNULAR, SPHERICAL, BOX, followed by 'SLAB' shield configurations. The calculation is based on point kernel technique. The source points are randomly sampled within the source volume. From each source point, optical path traversed in the source and shield media up to the detector location is estimated to calculate geometrical and material attenuations, and then corresponding buildup factor is obtained, which accounts for scattered contribution. Finally, the dose rate for entire source is obtained by summing over all sampled points. The application allows the user to select one of the seven regular geometrical bodies and provision exist to give source details such as emission energies, intensities, physical dimensions and material composition. Similar provision is provided to specify shield slab details. To aid the user, atomic numbers, densities, standard build factor materials and isotope list with respective emission energies and intensity for ready reference are given in dropdown combo boxes. Typical results obtained from this program are validated against existing point kernel gamma ray shielding codes. Additional facility is provided to compute fission product gamma ray source strengths based on the fuel type, burn up and cooling time. Plots of Fission product gamma ray source strengths, Gamma ray cross-sections and buildup factors can be optionally obtained, which enable the user to draw inference on the computed results. It is expected that this tool will be handy to all health physicists and radiological safety officers as it will be available on the internet. (author)

  20. Palpimanid spiders from Guyana: new species of the genera Fernandezina and Otiothops (Araneae, Palpimanidae, Otiothopinae

    Directory of Open Access Journals (Sweden)

    Grismado Cristian J.

    2002-01-01

    Full Text Available Two new species of the spider family Palpimanidae from Guyana are described: Fernandezina takutu, the first species of this genus known from this country andOtiothops giralunas, that seems to be the sister species of O. goloboffi Grismado, 1996 from northwestern Argentina.

  1. Quality of anti-malarials collected in the private and informal sectors in Guyana and Suriname

    Directory of Open Access Journals (Sweden)

    Evans Lawrence

    2012-06-01

    Full Text Available Abstract Background Despite a significant reduction in the number of malaria cases in Guyana and Suriname, this disease remains a major problem in the interior of both countries, especially in areas with gold mining and logging operations, where malaria is endemic. National malaria control programmes in these countries provide treatment to patients with medicines that are procured and distributed through regulated processes in the public sector. However, availability to medicines in licensed facilities (private sector and unlicensed facilities (informal sector is common, posing the risk of access to and use of non-recommended treatments and/or poor quality products. Methods To assess the quality of circulating anti-malarial medicines, samples were purchased in the private and informal sectors of Guyana and Suriname in 2009. The sampling sites were selected based on epidemiological data and/or distance from health facilities. Samples were analysed for identity, content, dissolution or disintegration, impurities, and uniformity of dosage units or weight variation according to manufacturer, pharmacopeial, or other validated method. Results Quality issues were observed in 45 of 77 (58% anti-malarial medicines sampled in Guyana of which 30 failed visual & physical inspection and 18 failed quality control tests. The proportion of monotherapy and ACT medicines failing quality control tests was 43% (13/30 and 11% (5/47 respectively. A higher proportion of medicines sampled from the private sector 34% (11/32 failed quality control tests versus 16% (7/45 in the informal sector. In Suriname, 58 medicines were sampled, of which 50 (86% were Artecom®, the fixed-dose combination of piperaquine-dihydroartemisinin-trimethoprim co-blistered with a primaquine phosphate tablet. All Artecom samples were found to lack a label claim for primaquine, thus failing visual and physical inspection. Conclusions The findings of the studies in both countries point to

  2. Quality of anti-malarials collected in the private and informal sectors in Guyana and Suriname.

    Science.gov (United States)

    Evans, Lawrence; Coignez, Veerle; Barojas, Adrian; Bempong, Daniel; Bradby, Sanford; Dijiba, Yanga; James, Makeida; Bretas, Gustavo; Adhin, Malti; Ceron, Nicolas; Hinds-Semple, Alison; Chibwe, Kennedy; Lukulay, Patrick; Pribluda, Victor

    2012-06-15

    Despite a significant reduction in the number of malaria cases in Guyana and Suriname, this disease remains a major problem in the interior of both countries, especially in areas with gold mining and logging operations, where malaria is endemic. National malaria control programmes in these countries provide treatment to patients with medicines that are procured and distributed through regulated processes in the public sector. However, availability to medicines in licensed facilities (private sector) and unlicensed facilities (informal sector) is common, posing the risk of access to and use of non-recommended treatments and/or poor quality products. To assess the quality of circulating anti-malarial medicines, samples were purchased in the private and informal sectors of Guyana and Suriname in 2009. The sampling sites were selected based on epidemiological data and/or distance from health facilities. Samples were analysed for identity, content, dissolution or disintegration, impurities, and uniformity of dosage units or weight variation according to manufacturer, pharmacopeial, or other validated method. Quality issues were observed in 45 of 77 (58%) anti-malarial medicines sampled in Guyana of which 30 failed visual & physical inspection and 18 failed quality control tests. The proportion of monotherapy and ACT medicines failing quality control tests was 43% (13/30) and 11% (5/47) respectively. A higher proportion of medicines sampled from the private sector 34% (11/32) failed quality control tests versus 16% (7/45) in the informal sector. In Suriname, 58 medicines were sampled, of which 50 (86%) were Artecom®, the fixed-dose combination of piperaquine-dihydroartemisinin-trimethoprim co-blistered with a primaquine phosphate tablet. All Artecom samples were found to lack a label claim for primaquine, thus failing visual and physical inspection. The findings of the studies in both countries point to significant problems with the quality of anti-malarial medicines

  3. Omni-directional selective shielding material based on amorphous glass coated microwires.

    Science.gov (United States)

    Ababei, G; Chiriac, H; David, V; Dafinescu, V; Nica, I

    2012-01-01

    The shielding effectiveness of the omni-directional selective shielding material based on CoFe-glass coated amorphous wires in 0.8 GHz-3 GHz microwave frequency range is investigated. The measurements were done in a controlled medium using a TEM cell and in the free space using horn antennas, respectively. Experimental results indicate that the composite shielding material can be developed with desired shielding effectiveness and selective absorption of the microwave frequency range by controlling the number of the layers and the length of microwires.

  4. Radiation shielding and effective atomic number studies in different types of shielding concretes, lead base and non-lead base glass systems for total electron interaction: A comparative study

    International Nuclear Information System (INIS)

    Kurudirek, Murat

    2014-01-01

    Highlights: • Radiation shielding calculations for concretes and glass systems. • Assigning effective atomic number for the given materials for total electron interaction. • Glass systems generally have better shielding ability than concretes. - Abstract: Concrete has been widely used as a radiation shielding material due to its extremely low cost. On the other hand, glass systems, which make everything inside visible to observers, are considered as promising shielding materials as well. In the present work, the effective atomic numbers, Z eff of some concretes and glass systems (industrial waste containing glass, Pb base glass and non-Pb base glass) have been calculated for total electron interaction in the energy region of 10 keV–1 GeV. Also, the continuous slowing down approximation (CSDA) ranges for the given materials have been calculated in the wide energy region to show the shielding effectiveness of the given materials. The glass systems are not only compared to different types of concretes but also compared to the lead base glass systems in terms of shielding. Moreover, the obtained results for total electron interaction have been compared to the results for total photon interaction wherever possible. In general, it has been observed that the glass systems have superior properties than most of the concretes over the high-energy region with respect to the electron interaction. Also, glass systems without lead show better electron stopping than lead base glasses at some energy regions as well. Along with the photon attenuation capability, it is seen that Fly Ash base glass systems have not only greater electron stopping capability but also have greater photon attenuation especially in high energy region when compared with standard shielding concretes

  5. Radiation shielding and effective atomic number studies in different types of shielding concretes, lead base and non-lead base glass systems for total electron interaction: A comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Kurudirek, Murat, E-mail: mkurudirek@gmail.com

    2014-12-15

    Highlights: • Radiation shielding calculations for concretes and glass systems. • Assigning effective atomic number for the given materials for total electron interaction. • Glass systems generally have better shielding ability than concretes. - Abstract: Concrete has been widely used as a radiation shielding material due to its extremely low cost. On the other hand, glass systems, which make everything inside visible to observers, are considered as promising shielding materials as well. In the present work, the effective atomic numbers, Z{sub eff} of some concretes and glass systems (industrial waste containing glass, Pb base glass and non-Pb base glass) have been calculated for total electron interaction in the energy region of 10 keV–1 GeV. Also, the continuous slowing down approximation (CSDA) ranges for the given materials have been calculated in the wide energy region to show the shielding effectiveness of the given materials. The glass systems are not only compared to different types of concretes but also compared to the lead base glass systems in terms of shielding. Moreover, the obtained results for total electron interaction have been compared to the results for total photon interaction wherever possible. In general, it has been observed that the glass systems have superior properties than most of the concretes over the high-energy region with respect to the electron interaction. Also, glass systems without lead show better electron stopping than lead base glasses at some energy regions as well. Along with the photon attenuation capability, it is seen that Fly Ash base glass systems have not only greater electron stopping capability but also have greater photon attenuation especially in high energy region when compared with standard shielding concretes.

  6. Parenting practices in Guyana and Trinidad and Tobago: Connections to preschoolers’ social and cognitive skills

    Directory of Open Access Journals (Sweden)

    Jaipaul L. Roopnarine

    2013-01-01

    Full Text Available Este i nfor me present a los result ados de dos est udios que exami naron los g rados de afección y el cont rol parental y sus asociaciones con las habilidades sociales e intelectuales de los niños en dos grupos de familias caribeñas. En el Estudio 1, 139 Indo madres de Guyana informó sobre el uso de calor y el control de la madre y en el Estudio 2, 180 madres y 180 padres de diversos grupos étnicos de Trinidad informaron sobre el uso de calor y el control en la crianza de sus hijos en edad preescolar. En ambos estudios, los maestros de preescolar proporcionan evaluaciones de las conductas pro-sociales de los niños, la ira, y las habilidades cognitivas. Los análisis revelaron dos grupos de madres de Guyana: un grupo fue alto en el calor y bajo el control y el otro era alto en el calor y moderadamente altos en control. Grupos idénticos se encontraron resultados para las madres y los padres trinitarios como en la muestra de Guyana. Madres y padres trinitarios fueron cruzadas clasifican en parejas por patrón de clúster. Setenta y uno por ciento de las parejas eran similares en sus patrones de crianza. Sólo las familias guyaneses tenían hijos les fue diferente en las habilidades sociales e intelectuales basadas en el modelo de clúster. Los datos son interpretados en términos de la utilización de ambos calor y el control del comportamiento como las prácticas que prevalecen en las comunidades culturales del Caribe y sus implicaciones para los resultados del desarrollo infantil.

  7. Exceptional diversity of Stefania (Anura, Cryptobatrachidae II: Six species from Mount Wokomung, Guyana

    Directory of Open Access Journals (Sweden)

    Ross D. MacCulloch

    2006-09-01

    Full Text Available Six species of Stefania were collected on Mount Wokomung, a tepui in the Pakaraima Mountains of Guyana. This unusually high diversity of Stefania is similar to that found on a neighbouring tepui, Mt. Ayanganna. The two tepuis support slightly different habitats. Conspecific Stefania from the two mountains differ somewhat in body size, toe disc size and colouration. Specimens from Mt. Wokomung are used to expand descriptions and distributions of some species.

  8. Monte Carlo based radial shield design of typical PWR reactor

    Energy Technology Data Exchange (ETDEWEB)

    Gul, Anas; Khan, Rustam; Qureshi, M. Ayub; Azeem, Muhammad Waqar; Raza, S.A. [Pakistan Institute of Engineering and Applied Sciences, Islamabad (Pakistan). Dept. of Nuclear Engineering; Stummer, Thomas [Technische Univ. Wien (Austria). Atominst.

    2016-11-15

    Neutron and gamma flux and dose equivalent rate distribution are analysed in radial and shields of a typical PWR type reactor based on the Monte Carlo radiation transport computer code MCNP5. The ENDF/B-VI continuous energy cross-section library has been employed for the criticality and shielding analysis. The computed results are in good agreement with the reference results (maximum difference is less than 56 %). It implies that MCNP5 a good tool for accurate prediction of neutron and gamma flux and dose rates in radial shield around the core of PWR type reactors.

  9. Evaluation of shielding parameters for heavy metal fluoride based tellurite-rich glasses for gamma ray shielding applications

    International Nuclear Information System (INIS)

    Sayyed, M.I.; Lakshminarayana, G.; Kityk, I.V.; Mahdi, M.A.

    2017-01-01

    In this work, we have evaluated the γ-ray shielding parameters such as mass attenuation coefficient (μ/ρ), effective atomic number (Z eff ), half value layer (HVL), mean free path (MFP) and exposure buildup factors (EBF) for heavy metal fluoride (PbF 2 ) based tellurite-rich glasses. In addition, neutron total macroscopic cross sections (∑ R ) for these glasses were also calculated. The maximum value for µ/ρ, Z eff and ∑ R was found for heavy metal (Bi 2 O 3 ) oxide introduced glass. The results of the selected glasses have been compared, in terms of MFP with different glass systems. The shielding effectiveness of the selected glasses is found comparable or better than of common ones, which indicates that these glasses with suitable oxides could be developed for gamma ray shielding applications. - Highlights: • μ/ρ, Z eff , HVL and MFP for PbF 2 based tellurite-rich glasses have been calculated. • µ/ρ and Z eff depend on the photon energy and chemical composition of the glasses. • EBF values of these glasses have been calculated using G-P fitting method. • The maximum value for µ/ρ and Z eff was found for Bi 2 O 3 oxide introduced glass. • New types of non-traditional radiation shielding glasses are demonstrated.

  10. Microbial properties and soil respiration in submontane forest of Venezuelan Guyana: characteristics and response to fertilizer treatments

    NARCIS (Netherlands)

    Priess, J.A.; Folster, H.

    2001-01-01

    The distribution of vegetation types in Venezuelan Guyana (in the `Canaima' National Park) represents a transitional stage in a long term process of savannization, a process considered to be conditioned by a combined chemical and intermittent drought stress. All types of woody vegetation in this

  11. Evaluation of shielding parameters for heavy metal fluoride based tellurite-rich glasses for gamma ray shielding applications

    Science.gov (United States)

    Sayyed, M. I.; Lakshminarayana, G.; Kityk, I. V.; Mahdi, M. A.

    2017-10-01

    In this work, we have evaluated the γ-ray shielding parameters such as mass attenuation coefficient (μ/ρ), effective atomic number (Zeff), half value layer (HVL), mean free path (MFP) and exposure buildup factors (EBF) for heavy metal fluoride (PbF2) based tellurite-rich glasses. In addition, neutron total macroscopic cross sections (∑R) for these glasses were also calculated. The maximum value for μ/ρ, Zeff and ∑R was found for heavy metal (Bi2O3) oxide introduced glass. The results of the selected glasses have been compared, in terms of MFP with different glass systems. The shielding effectiveness of the selected glasses is found comparable or better than of common ones, which indicates that these glasses with suitable oxides could be developed for gamma ray shielding applications.

  12. Neutron shielding material

    International Nuclear Information System (INIS)

    Nodaka, M.; Iida, T.; Taniuchi, H.; Yosimura, K.; Nagahama, H.

    1993-01-01

    From among the neutron shielding materials of the 'kobesh' series developed by Kobe Steel, Ltd. for transport and storage packagings, silicon rubber base type material has been tested for several items with a view to practical application and official authorization, and in order to determine its adaptability to actual vessels. Silicon rubber base type 'kobesh SR-T01' is a material in which, from among the silicone rubber based neutron shielding materials, the hydrogen content is highest and the boron content is most optimized. Its neutron shielding capability has been already described in the previous report (Taniuchi, 1986). The following tests were carried out to determine suitability for practical application; 1) Long-term thermal stability test 2) Pouring test on an actual-scale model 3) Fire test The experimental results showed that the silicone rubber based neutron shielding material has good neutron shielding capability and high long-term fire resistance, and that it can be applied to the advanced transport packaging. (author)

  13. PC based temporary shielding administrative procedure (TSAP)

    International Nuclear Information System (INIS)

    Olsen, D.E.; Pederson, G.E.; Hamby, P.N.

    1995-01-01

    A completely new Administrative Procedure for temporary shielding was developed for use at Commonwealth Edison's six nuclear stations. This procedure promotes the use of shielding, and addresses industry requirements for the use and control of temporary shielding. The importance of an effective procedure has increased since more temporary shielding is being used as ALARA goals become more ambitious. To help implement the administrative procedure, a personal computer software program was written to incorporate the procedural requirements. This software incorporates the useability of a Windows graphical user interface with extensive help and database features. This combination of a comprehensive administrative procedure and user friendly software promotes the effective use and management of temporary shielding while ensuring that industry requirements are met

  14. PC based temporary shielding administrative procedure (TSAP)

    Energy Technology Data Exchange (ETDEWEB)

    Olsen, D.E.; Pederson, G.E. [Sargent & Lundy, Chicago, IL (United States); Hamby, P.N. [Commonwealth Edison Co., Downers Grove, IL (United States)

    1995-03-01

    A completely new Administrative Procedure for temporary shielding was developed for use at Commonwealth Edison`s six nuclear stations. This procedure promotes the use of shielding, and addresses industry requirements for the use and control of temporary shielding. The importance of an effective procedure has increased since more temporary shielding is being used as ALARA goals become more ambitious. To help implement the administrative procedure, a personal computer software program was written to incorporate the procedural requirements. This software incorporates the useability of a Windows graphical user interface with extensive help and database features. This combination of a comprehensive administrative procedure and user friendly software promotes the effective use and management of temporary shielding while ensuring that industry requirements are met.

  15. Variation in indigenous forest resource use in central Guyana.

    Directory of Open Access Journals (Sweden)

    Claire M P Ozanne

    Full Text Available Sustainable forest conservation strategies should be based on local as well as landscape-scale forest resource use data. Using ecological and sociological techniques, we test the hypotheses that (1 forest resource use differs between ethnic and socioeconomic indigenous groups and (2 that this difference results in differing spatial patterns of resource use, with implications for forest diversity and for conservation planning. In the North Rupununi Guyana, three adjacent indigenous communities (differing in their indigenous/immigrant balance were recorded using 73 animal and 164 plant species (plus several unidentified ethno-species. Farm sites formed important foci for most forest based activities and ex-farm sites supported similar floristic diversity to surrounding forest. Resource usage differences between communities could be attributed to socio-cultural drivers, e.g. mammal meat consumption and the use of the fruits from the palm tree A. maripa were higher in more traditional households. When extracting household construction timber, lower income groups created small scattered felling sites akin to tree fall gaps whereas higher income groups created larger gaps. Lower income (indigenous households tended to clear larger but more contained sites for farming while mixed or non-Amerindian household tended to clear smaller but more widely dispersed farm sites. These variations resulted in different patterns of forest disturbance originating from agriculture and timber extraction.

  16. Impact of PETIT-SAUT hydroelectric dam on aquatic life (French Guyana)

    International Nuclear Information System (INIS)

    Sissakian, C.

    1992-01-01

    The construction of the hydroelectric scheme of PETIT-SAUT in French Guyana creates a reservoir which covers 310 km 2 of tropical rain forest. This hydroelectric scheme has an influence on the various aspects of the environment. One of the most important aspects is the modification of the water quality and of the aquatic life due to the degradation of organic matter. Some studies of the biology of these area fishes are initiated. At the same time, Electricite de France studies some constructive arrangements and reservoir managements to assure, the most rapidly possible, a return to an aquatic normal life. 6 refs

  17. Development of a Waterproof Crack-Based Stretchable Strain Sensor Based on PDMS Shielding

    Directory of Open Access Journals (Sweden)

    Seong Kyung Hong

    2018-04-01

    Full Text Available This paper details the design of a poly(dimethylsiloxane (PDMS-shielded waterproof crack-based stretchable strain sensor, in which the electrical characteristics and sensing performance are not influenced by changes in humidity. This results in a higher number of potential applications for the sensor. A previously developed omni-purpose stretchable strain (OPSS sensor was used as the basis for this work, which utilizes a metal cracking structure and provides a wide sensing range and high sensitivity. Changes in the conductivity of the OPSS sensor, based on humidity conditions, were investigated along with the potential possibility of using the design as a humidity sensor. However, to prevent conductivity variation, which can decrease the reliability and sensing ability of the OPSS sensor, PDMS was utilized as a shielding layer over the OPSS sensor. The PDMS-shielded OPSS sensor showed approximately the same electrical characteristics as previous designs, including in a high humidity environment, while maintaining its strain sensing capabilities. The developed sensor shows promise for use under high humidity conditions and in underwater applications. Therefore, considering its unique features and reliable sensing performance, the developed PDMS-shielded waterproof OPSS sensor has potential utility in a wide range of applications, such as motion monitoring, medical robotics and wearable healthcare devices.

  18. Development of a Waterproof Crack-Based Stretchable Strain Sensor Based on PDMS Shielding.

    Science.gov (United States)

    Hong, Seong Kyung; Yang, Seongjin; Cho, Seong J; Jeon, Hyungkook; Lim, Geunbae

    2018-04-12

    This paper details the design of a poly(dimethylsiloxane) (PDMS)-shielded waterproof crack-based stretchable strain sensor, in which the electrical characteristics and sensing performance are not influenced by changes in humidity. This results in a higher number of potential applications for the sensor. A previously developed omni-purpose stretchable strain (OPSS) sensor was used as the basis for this work, which utilizes a metal cracking structure and provides a wide sensing range and high sensitivity. Changes in the conductivity of the OPSS sensor, based on humidity conditions, were investigated along with the potential possibility of using the design as a humidity sensor. However, to prevent conductivity variation, which can decrease the reliability and sensing ability of the OPSS sensor, PDMS was utilized as a shielding layer over the OPSS sensor. The PDMS-shielded OPSS sensor showed approximately the same electrical characteristics as previous designs, including in a high humidity environment, while maintaining its strain sensing capabilities. The developed sensor shows promise for use under high humidity conditions and in underwater applications. Therefore, considering its unique features and reliable sensing performance, the developed PDMS-shielded waterproof OPSS sensor has potential utility in a wide range of applications, such as motion monitoring, medical robotics and wearable healthcare devices.

  19. RadShield: semiautomated shielding design using a floor plan driven graphical user interface.

    Science.gov (United States)

    DeLorenzo, Matthew C; Wu, Dee H; Yang, Kai; Rutel, Isaac B

    2016-09-08

    The purpose of this study was to introduce and describe the development of RadShield, a Java-based graphical user interface (GUI), which provides a base design that uniquely performs thorough, spatially distributed calculations at many points and reports the maximum air-kerma rate and barrier thickness for each barrier pursuant to NCRP Report 147 methodology. Semiautomated shielding design calculations are validated by two approaches: a geometry-based approach and a manual approach. A series of geometry-based equations were derived giv-ing the maximum air-kerma rate magnitude and location through a first derivative root finding approach. The second approach consisted of comparing RadShield results with those found by manual shielding design by an American Board of Radiology (ABR)-certified medical physicist for two clinical room situations: two adjacent catheterization labs, and a radiographic and fluoroscopic (R&F) exam room. RadShield's efficacy in finding the maximum air-kerma rate was compared against the geometry-based approach and the overall shielding recommendations by RadShield were compared against the medical physicist's shielding results. Percentage errors between the geometry-based approach and RadShield's approach in finding the magnitude and location of the maximum air-kerma rate was within 0.00124% and 14 mm. RadShield's barrier thickness calculations were found to be within 0.156 mm lead (Pb) and 0.150 mm lead (Pb) for the adjacent catheteriza-tion labs and R&F room examples, respectively. However, within the R&F room example, differences in locating the most sensitive calculation point on the floor plan for one of the barriers was not considered in the medical physicist's calculation and was revealed by the RadShield calculations. RadShield is shown to accurately find the maximum values of air-kerma rate and barrier thickness using NCRP Report 147 methodology. Visual inspection alone of the 2D X-ray exam distribution by a medical physicist may not

  20. Shielding benchmark problems

    International Nuclear Information System (INIS)

    Tanaka, Shun-ichi; Sasamoto, Nobuo; Oka, Yoshiaki; Kawai, Masayoshi; Nakazawa, Masaharu.

    1978-09-01

    Shielding benchmark problems were prepared by the Working Group of Assessment of Shielding Experiments in the Research Comittee on Shielding Design of the Atomic Energy Society of Japan, and compiled by the Shielding Laboratory of Japan Atomic Energy Research Institute. Twenty-one kinds of shielding benchmark problems are presented for evaluating the calculational algorithm and the accuracy of computer codes based on the discrete ordinates method and the Monte Carlo method and for evaluating the nuclear data used in the codes. (author)

  1. Radiation shielding lead shield

    International Nuclear Information System (INIS)

    Dei, Shoichi.

    1991-01-01

    The present invention concerns lead shields for radiation shielding. Shield boxes are disposed so as to surround a pipeline through which radioactive liquids, mists or like other objects are passed. Flanges are formed to each of the end edges of the shield boxes and the shield boxes are connected to each other by the flanges. Upon installation, empty shield boxes not charged with lead particles and iron plate shields are secured at first at the periphery of the pipeline. Then, lead particles are charged into the shield boxes. This attains a state as if lead plate corresponding to the depth of the box is disposed. Accordingly, operations for installation, dismantling and restoration can be conducted in an empty state with reduced weight to facilitate the operations. (I.S.)

  2. About the Scythian Shields

    Directory of Open Access Journals (Sweden)

    About the Scythian Shields

    2017-10-01

    Full Text Available Shields played major role in the armament system of the Scythians. Made from organic materials, they are poorly traced on the materials of archaeological excavations. Besides, scaly surface of shields was often perceived in practice as the remnants of the scaly armor. E. V. Chernenko was able to discern the difference between shields’ scaly plates and armor scales. The top edge of the scales was bent inwards, and shield plates had a wire fixation. These observations let significantly increase the number of shields, found in the burial complexes of the Scythians. The comparison of archaeological materials and the images of Scythian warriors allow distinguishing the main forms of Scythian shields. All shields are divided into fencing shields and cover shields. The fencing shields include round wooden shields, reinforced with bronze sheet, and round moon-shaped shields with a notch at the top, with a metal scaly surface. They came to the Scythians under the Greek influence and are known in the monuments of the 4th century BC. Oval shields with scaly surface (back cover shields were used by the Scythian cavalry. They protected the rider in case of frontal attack, and moved back in case of maneuver or closein fighting. Scythian battle tactics were based on rapid approaching the enemy and throwing spears and further rapid withdrawal. Spears stuck in the shields of enemies, forcing them to drop the shields, uncover, and in this stage of the battle the archers attacked the disorganized ranks of the enemy. That was followed by the stage of close fight. Oval form of a wooden shield with leather covering was used by the Scythian infantry and spearmen. Rectangular shields, including wooden shields and the shields pleached from rods, represented a special category. The top of such shield was made of wood, and a pleached pad on leather basis was attached to it. This shield could be a reliable protection from arrows, but it could not protect against javelins

  3. Paddle-based rotating-shield brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yunlong; Xu, Weiyu [Department of Electrical and Computer Engineering, University of Iowa, 4016 Seamans Center, Iowa City, Iowa 52242 (United States); Flynn, Ryan T.; Kim, Yusung; Bhatia, Sudershan K.; Buatti, John M. [Department of Radiation Oncology, University of Iowa, 200 Hawkins Drive, Iowa City, Iowa 52242 (United States); Dadkhah, Hossein [Department of Biomedical Engineering, University of Iowa, 1402 Seamans Center, Iowa City, Iowa 52242 (United States); Wu, Xiaodong, E-mail: xiaodong-wu@uiowa.edu [Department of Electrical and Computer Engineering, University of Iowa, 4016 Seamans Center, Iowa City, Iowa 52242 and Department of Radiation Oncology, University of Iowa, 200 Hawkins Drive, Iowa City, Iowa 52242 (United States)

    2015-10-15

    Purpose: The authors present a novel paddle-based rotating-shield brachytherapy (P-RSBT) method, whose radiation-attenuating shields are formed with a multileaf collimator (MLC), consisting of retractable paddles, to achieve intensity modulation in high-dose-rate brachytherapy. Methods: Five cervical cancer patients using an intrauterine tandem applicator were considered to assess the potential benefit of the P-RSBT method. The P-RSBT source used was a 50 kV electronic brachytherapy source (Xoft Axxent™). The paddles can be retracted independently to form multiple emission windows around the source for radiation delivery. The MLC was assumed to be rotatable. P-RSBT treatment plans were generated using the asymmetric dose–volume optimization with smoothness control method [Liu et al., Med. Phys. 41(11), 111709 (11pp.) (2014)] with a delivery time constraint, different paddle sizes, and different rotation strides. The number of treatment fractions (fx) was assumed to be five. As brachytherapy is delivered as a boost for cervical cancer, the dose distribution for each case includes the dose from external beam radiotherapy as well, which is 45 Gy in 25 fx. The high-risk clinical target volume (HR-CTV) doses were escalated until the minimum dose to the hottest 2 cm{sup 3} (D{sub 2cm{sup 3}}) of either the rectum, sigmoid colon, or bladder reached their tolerance doses of 75, 75, and 90 Gy{sub 3}, respectively, expressed as equivalent doses in 2 Gy fractions (EQD2 with α/β = 3 Gy). Results: P-RSBT outperformed the two other RSBT delivery techniques, single-shield RSBT (S-RSBT) and dynamic-shield RSBT (D-RSBT), with a properly selected paddle size. If the paddle size was angled at 60°, the average D{sub 90} increases for the delivery plans by P-RSBT on the five cases, compared to S-RSBT, were 2.2, 8.3, 12.6, 11.9, and 9.1 Gy{sub 10}, respectively, with delivery times of 10, 15, 20, 25, and 30 min/fx. The increases in HR-CTV D{sub 90}, compared to D-RSBT, were 16

  4. Computing Moment-Based Probability Tables for Self-Shielding Calculations in Lattice Codes

    International Nuclear Information System (INIS)

    Hebert, Alain; Coste, Mireille

    2002-01-01

    As part of the self-shielding model used in the APOLLO2 lattice code, probability tables are required to compute self-shielded cross sections for coarse energy groups (typically with 99 or 172 groups). This paper describes the replacement of the multiband tables (typically with 51 subgroups) with moment-based tables in release 2.5 of APOLLO2. An improved Ribon method is proposed to compute moment-based probability tables, allowing important savings in CPU resources while maintaining the accuracy of the self-shielding algorithm. Finally, a validation is presented where the absorption rates obtained with each of these techniques are compared with exact values obtained using a fine-group elastic slowing-down calculation in the resolved energy domain. Other results, relative to the Rowland's benchmark and to three assembly production cases, are also presented

  5. Forest filled with gaps : effects of gap size on water and nutrient cycling in tropical rain forest : a study in Guyana

    NARCIS (Netherlands)

    Dam, O. van

    2001-01-01

    Guyana's forests are selectively logged and a forest management is desired that is economically sustainable and ecologically responsible. Canopy gaps, created by selective logging, induce changes to microclimatic and edaphic conditions. These changes influence the regeneration of the

  6. Radiation Shielding Properties Comparison of Pb-Based Silicate, Borate, and Phosphate Glass Matrices

    Directory of Open Access Journals (Sweden)

    Suwimon Ruengsri

    2014-01-01

    Full Text Available Theoretical calculations of mass attenuation coefficients, partial interactions, atomic cross-section, and effective atomic numbers of PbO-based silicate, borate, and phosphate glass systems have been investigated at 662 keV. PbO-based silicate glass has been found with the highest total mass attenuation coefficient and then phosphate and borate glasses, respectively. Compton scattering has been the dominate interaction contributed to the different total attenuation coefficients in each of the glass matrices. The silicate and phosphate glass systems are more appropriate choices as lead-based radiation shielding glass than the borate glass system. Moreover, comparison of results has shown that the glasses possess better shielding properties than standard shielding concretes, suggesting a smaller size requirement in addition to transparency in the visible region.

  7. RADIO SHIELDING PROPERTIES OF CONCRETE BASED ON SHUNGITE NANOMATERIALS

    Directory of Open Access Journals (Sweden)

    BELOUSOVA Elena Sergeevna

    2013-04-01

    Full Text Available Modifications of shielding construction materials based on Portland cement with the addition of powder nanomaterial shungite were developed. Attenuation and re­flection of electromagnetic radiation for obtained materials were studied. Recommen­dations for using are given.

  8. CAD-Based Shielding Analysis for ITER Port Diagnostics

    Directory of Open Access Journals (Sweden)

    Serikov Arkady

    2017-01-01

    Full Text Available Radiation shielding analysis conducted in support of design development of the contemporary diagnostic systems integrated inside the ITER ports is relied on the use of CAD models. This paper presents the CAD-based MCNP Monte Carlo radiation transport and activation analyses for the Diagnostic Upper and Equatorial Port Plugs (UPP #3 and EPP #8, #17. The creation process of the complicated 3D MCNP models of the diagnostics systems was substantially accelerated by application of the CAD-to-MCNP converter programs MCAM and McCad. High performance computing resources of the Helios supercomputer allowed to speed-up the MCNP parallel transport calculations with the MPI/OpenMP interface. The found shielding solutions could be universal, reducing ports R&D costs. The shield block behind the Tritium and Deposit Monitor (TDM optical box was added to study its influence on Shut-Down Dose Rate (SDDR in Port Interspace (PI of EPP#17. Influence of neutron streaming along the Lost Alpha Monitor (LAM on the neutron energy spectra calculated in the Tangential Neutron Spectrometer (TNS of EPP#8. For the UPP#3 with Charge eXchange Recombination Spectroscopy (CXRS-core, an excessive neutron streaming along the CXRS shutter, which should be prevented in further design iteration.

  9. CAD-Based Shielding Analysis for ITER Port Diagnostics

    Science.gov (United States)

    Serikov, Arkady; Fischer, Ulrich; Anthoine, David; Bertalot, Luciano; De Bock, Maartin; O'Connor, Richard; Juarez, Rafael; Krasilnikov, Vitaly

    2017-09-01

    Radiation shielding analysis conducted in support of design development of the contemporary diagnostic systems integrated inside the ITER ports is relied on the use of CAD models. This paper presents the CAD-based MCNP Monte Carlo radiation transport and activation analyses for the Diagnostic Upper and Equatorial Port Plugs (UPP #3 and EPP #8, #17). The creation process of the complicated 3D MCNP models of the diagnostics systems was substantially accelerated by application of the CAD-to-MCNP converter programs MCAM and McCad. High performance computing resources of the Helios supercomputer allowed to speed-up the MCNP parallel transport calculations with the MPI/OpenMP interface. The found shielding solutions could be universal, reducing ports R&D costs. The shield block behind the Tritium and Deposit Monitor (TDM) optical box was added to study its influence on Shut-Down Dose Rate (SDDR) in Port Interspace (PI) of EPP#17. Influence of neutron streaming along the Lost Alpha Monitor (LAM) on the neutron energy spectra calculated in the Tangential Neutron Spectrometer (TNS) of EPP#8. For the UPP#3 with Charge eXchange Recombination Spectroscopy (CXRS-core), an excessive neutron streaming along the CXRS shutter, which should be prevented in further design iteration.

  10. Neutron shieldings

    International Nuclear Information System (INIS)

    Tarutani, Kohei

    1979-01-01

    Purpose: To decrease the stresses resulted by the core bendings to the base of an entrance nozzle. Constitution: Three types of round shielding rods of different diameter are arranged in a hexagonal tube. The hexagonal tube is provided with several spacer pads receiving the loads from the core constrain mechanism at its outer circumference, a handling head for a fuel exchanger at its top and an entrance nozzle for self-holding the neutron shieldings and flowing heat-removing coolants at its bottom. The diameters for R 1 , R 2 and R 3 for the round shielding rods are designed as: 0.1 R 1 2 1 and 0.2 R 1 2 1 . Since a plurality of shielding rods of small diameter are provided, soft structure are obtained and a plurality of coolant paths are formed. (Furukawa, Y.)

  11. Shielding benchmark problems, (2)

    International Nuclear Information System (INIS)

    Tanaka, Shun-ichi; Sasamoto, Nobuo; Oka, Yoshiaki; Shin, Kazuo; Tada, Keiko.

    1980-02-01

    Shielding benchmark problems prepared by Working Group of Assessment of Shielding Experiments in the Research Committee on Shielding Design in the Atomic Energy Society of Japan were compiled by Shielding Laboratory in Japan Atomic Energy Research Institute. Fourteen shielding benchmark problems are presented newly in addition to twenty-one problems proposed already, for evaluating the calculational algorithm and accuracy of computer codes based on discrete ordinates method and Monte Carlo method and for evaluating the nuclear data used in codes. The present benchmark problems are principally for investigating the backscattering and the streaming of neutrons and gamma rays in two- and three-dimensional configurations. (author)

  12. Shielding Calculations for PUSPATI TRIGA Reactor (RTP) Fuel Transfer Cask with Micro shield

    International Nuclear Information System (INIS)

    Nurhayati Ramli; Ahmad Nabil Abdul Rahim; Ariff Shah Ismail

    2011-01-01

    The shielding calculations for RTP fuel transfer cask was performed by using computer code Micro shield 7.02. Micro shield is a computer code designed to provide a model to be used for shielding calculations. The results of the calculations can be obtained fast but the code is not suitable for complex geometries with a shielding composed of more than one material. Nevertheless, the program is sufficient for As Low As Reasonable Achievable (ALARA) optimization calculations. In this calculation, a geometry based on the conceptual design of RTP fuel transfer cask was modeled. Shielding material used in the calculations were lead (Pb) and stainless steel 304 (SS304). The results obtained from these calculations are discussed in this paper. (author)

  13. Radiation shielding plate

    International Nuclear Information System (INIS)

    Kobayashi, Torakichi; Sugawara, Takeo.

    1983-01-01

    Purpose: To reduce the weight and stabilize the configuration of a radiation shielding plate which is used in close contact with an object to be irradiated with radiation rays. Constitution: The radiation shielding plate comprises a substrate made of lead glass and a metallic lead coating on the surface of the substrate by means of plating, vapor deposition or the like. Apertures for permeating radiation rays are formed to the radiation shielding plate. Since the shielding plate is based on a lead glass plate, a sufficient mechanical strength can be obtained with a thinner structure as compared with the conventional plate made of metallic lead. Accordingly, if the shielding plate is disposed on a soft object to be irradiated with radiation rays, the object and the plate itself less deform to obtain a radiation irradiation pattern with distinct edges. (Moriyama, K.)

  14. SHIELD 1.0: development of a shielding calculator program in diagnostic radiology

    International Nuclear Information System (INIS)

    Santos, Romulo R.; Real, Jessica V.; Luz, Renata M. da; Friedrich, Barbara Q.; Silva, Ana Maria Marques da

    2013-01-01

    In shielding calculation of radiological facilities, several parameters are required, such as occupancy, use factor, number of patients, source-barrier distance, area type (controlled and uncontrolled), radiation (primary or secondary) and material used in the barrier. The shielding design optimization requires a review of several options about the physical facility design and, mainly, the achievement of the best cost-benefit relationship for the shielding material. To facilitate the development of this kind of design, a program to calculate the shielding in diagnostic radiology was implemented, based on data and limits established by National Council on Radiation Protection and Measurements (NCRP) 147 and SVS-MS 453/98. The program was developed in C⌗ language, and presents a graphical interface for user data input and reporting capabilities. The module initially implemented, called SHIELD 1.0, refers to calculating barriers for conventional X-ray rooms. The program validation was performed by the comparison with the results of examples of shielding calculations presented in NCRP 147.

  15. Prediction of melanoma metastasis by the Shields index based on lymphatic vessel density

    Directory of Open Access Journals (Sweden)

    Metcalfe Chris

    2010-05-01

    Full Text Available Abstract Background Melanoma usually presents as an initial skin lesion without evidence of metastasis. A significant proportion of patients develop subsequent local, regional or distant metastasis, sometimes many years after the initial lesion was removed. The current most effective staging method to identify early regional metastasis is sentinel lymph node biopsy (SLNB, which is invasive, not without morbidity and, while improving staging, may not improve overall survival. Lymphatic density, Breslow's thickness and the presence or absence of lymphatic invasion combined has been proposed to be a prognostic index of metastasis, by Shields et al in a patient group. Methods Here we undertook a retrospective analysis of 102 malignant melanomas from patients with more than five years follow-up to evaluate the Shields' index and compare with existing indicators. Results The Shields' index accurately predicted outcome in 90% of patients with metastases and 84% without metastases. For these, the Shields index was more predictive than thickness or lymphatic density. Alternate lymphatic measurement (hot spot analysis was also effective when combined into the Shields index in a cohort of 24 patients. Conclusions These results show the Shields index, a non-invasive analysis based on immunohistochemistry of lymphatics surrounding primary lesions that can accurately predict outcome, is a simple, useful prognostic tool in malignant melanoma.

  16. The CRE mission in French Guyana. Report, February 2017

    International Nuclear Information System (INIS)

    2017-01-01

    This document reports a mission in French Guyana which aimed at assessing technical and logistic constraints on the electric power system, and the situation of isolated communities, and also at meeting the various actors (EDF as local producer and grid manager, institutional actors, actors involved in the development of the biomass sector, managers of the Kourou space centre which is the main consumer, representatives of the mining industry). The first part of this report proposes an overview of the demographical situation and of stakes of economic development which are both determining factors of the evolutions of the electricity system. The second part proposes an analysis and assessment of the electric power system of the Guyanese coast: production fleet, maintenance of a dam, replacement of a power plant, moderate development of photovoltaic energy, low development but promising perspectives for other renewable energies (hydraulic, biomass), geographical distribution of future production means, development of storage. The third part addresses the power system of inland communities: increasing population with increasing needs, isolated areas, isolated and mainly thermal production plants, lack of support and development

  17. On the occurrence of bryophytes and macrolichens in different lowland rain forest types at Mabura Hill, Guyana

    OpenAIRE

    Cornelissen, J. Hans C.; Gradstein, Stephan Robbert

    1990-01-01

    A floristic and ecological study of bryophytes and macrolichens in different lowland rain forest types around Mabura Hill, Guyana, South America, yielded 170 species: 52 mosses, 82 liverworts and 36 macrolichens. Lejeuneaceae account for about 30% of the species and are the dominant cryptogamic family of the lowland rain forest. Special attention was paid to the flora of the forest canopy, by using mountaineering techniques. It appeared that 50% of the bryophyte species and 86% of the macroli...

  18. Double-layer neutron shield design as neutron shielding application

    Science.gov (United States)

    Sariyer, Demet; Küçer, Rahmi

    2018-02-01

    The shield design in particle accelerators and other high energy facilities are mainly connected to the high-energy neutrons. The deep penetration of neutrons through massive shield has become a very serious problem. For shielding to be efficient, most of these neutrons should be confined to the shielding volume. If the interior space will become limited, the sufficient thickness of multilayer shield must be used. Concrete and iron are widely used as a multilayer shield material. Two layers shield material was selected to guarantee radiation safety outside of the shield against neutrons generated in the interaction of the different proton energies. One of them was one meter of concrete, the other was iron-contained material (FeB, Fe2B and stainless-steel) to be determined shield thicknesses. FLUKA Monte Carlo code was used for shield design geometry and required neutron dose distributions. The resulting two layered shields are shown better performance than single used concrete, thus the shield design could leave more space in the interior shielded areas.

  19. FIRE-RESISTANT SHIELDING COATING BASED ON SHUNGITE-CONTAINING PAINT

    Directory of Open Access Journals (Sweden)

    BELOUSOVA Elena Sergeevna

    2013-08-01

    Full Text Available Today when specific shielded facilities are designed the construction materials and shields should meet a range of fire safety requirements. A composite coating on the basis of a water-based fire-resistant paint filled with shungite nanopowder can be applied onto walls, floors, ceilings and other surfaces in the shielded areas to reduce electromagnetic radiation and simultaneously to ensure fire safety. Shungit is a mineral with multilayer carbon fullerene globules which diameter is 10–30 nm. Due to the high conductivity shungite is able to weaken electromagnetic radiation. A coating made of schungite-containing paint on a cellulose substrate was subjected to the open flame under the temperature of 1700° C for 3 minutes and 40 seconds. That resulted in the formation of insulating foam layer without mechanical damage of the substrate. The XRD diffraction analysis of the powder obtained in the process of flame influence on the coating showed the formation of the such substances as orthoclase, barite, rutile, etc. Carbon contained in shungit and used as a filler for the fireproof paint wasn’t detected. This fact indicates carbon oxidation as the result of its burning out. The shielding efficiency of the composite coating after open flame exposure was measured for the frequency range 8…12 GHz with the use of the panoramic attenuation meter and voltage standing wave ratio meter YA2R-67-61 with a sweep generator and waveguides. After that the reflection and transmission coefficients were calculated. The results of measurements and calculations showed decrease of the reflection and transmission coefficients due to conductivity decrease and dielectric losses changes of the composite coating provided by silica content increase and carbon percentage decrease.

  20. Book review: Kok, P. J. R. and M. Kalamandeen. 2008. Introduction to the taxonomy of the amphibians of Kaieteur National Park, Guyana

    Directory of Open Access Journals (Sweden)

    Ross D. MacCulloch

    2009-07-01

    Full Text Available Book review: Kok, P. J. R. and M. Kalamandeen. 2008. Introduction to the taxonomy of the amphibians of Kaieteur National Park, Guyana. ix + 278 pp; numerous color photographs; Abc Taxa, Volume 5. Brussels, Belgium.ISBN 1784-1283; 18 × 25 cm (soft coverISSN 1784-1291 online PDF

  1. Studies of ionizing radiation shielding effectiveness of silica-based commercial glasses used in Bangladeshi dwellings

    Directory of Open Access Journals (Sweden)

    Sabina Yasmin

    2018-06-01

    Full Text Available Following the rapid growing economy, the Bangladeshi dwellers are replacing their traditional (mud-, bamboo-, and wood-based houses to modern multistoried buildings, where different types of glasses are being used as decorative as well as structural materials due to their various advantageous properties. In this study, we inquire the protective and dosimetric capability of commercial glasses for ionizing radiation. Four branded glass samples (PHP-Bangladesh, Osmania-Bangladesh, Nasir-Bangladesh, and Rider-China of same thickness and color but different elemental weight fractions were analyzed for shielding and dosimetric properties. The chemical composition of the studied material was evaluated by EDX technique. A well-shielded HPGe γ-ray spectrometer combined with associated electronics was used to evaluate the attenuation coefficients of the studied materials for 59 keV, 661 keV, 1173 keV and 1332 keV photon energies. A number of shielding parameters- half value layer (HVL, radiation protection efficiency (RPE and effective atomic number (Zeff were also evaluated. The data were compared with the available literature (where applicable to understand its shielding capability relative to the standard materials such as lead. Among the studied brands, Rider (China shows relatively better indices to be used as ionizing radiation shielding material. The obtained, Zeff of the studied glass samples showed comparable values to the TLD-200 dosimeter, thus considered suitable for environmental radiation monitoring purposes. Keywords: Silica-based commercial glass, HPGe γ-ray spectrometry, EDX analyses, Shielding effectiveness, Dosimetric properties

  2. Shielding practice

    International Nuclear Information System (INIS)

    Sauermann, P.F.

    1985-08-01

    The basis of shielding practice against external irradiation is shown in a simple way. For most sources of radiation (point sources) occurring in shielding practice, the basic data are given, mainly in the form of tables, which are required to solve the shielding problems. The application of these data is explained and discussed using practical examples. Thickness of shielding panes of glove boxes for α and β radiation; shielding of sealed γ-radiography sources; shielding of a Co-60 radiation source, and of the manipulator panels for hot cells; damping factors for γ radiation and neutrons; shielding of fast and thermal neutrons, and of bremsstrahlung (X-ray tubes, Kr-85 pressure gas cylinders, 42 MeV betatrons, 20 MeV linacs); two-fold shielding (lead glass windows for hot cells, 14 MeV neutron generators); shielding against scattered radiation. (orig./HP) [de

  3. Guyana - How Do You Know Where to Get the Information You Need? Determining Ethics Approval Requirements in a Developing Country

    Directory of Open Access Journals (Sweden)

    Gloria Song

    2018-02-01

    Full Text Available Determining the process for obtaining local research ethics approval, or whether such a requirement even exists, may not always be straightforward in the context of some developing countries where such information may not be easily accessible to overseas researchers. How far do a researcher's ethical obligations extend in determining whether there is a requirement for local research ethics approval, and what form this would take (e.g., institutional or centralised ethics review? In other words, how far should a researcher be expected to go in seeking out local ethics approval, especially where such information is not readily available? As part of this discussion, this case study describes the steps that I took as the principal researcher, before I was able to reasonably conclude that no national ethics approval requirement existed in Guyana for my particular research, which involved interviewing justice service providers about the implementation of Guyana's Domestic Violence Act. Drawing on this experience, I discuss various considerations that an international development researcher should bear in mind when planning and conducting research that seeks to meet leading international norms of research ethics.

  4. Radiation shielding device

    International Nuclear Information System (INIS)

    Nakagawa, Takahiro; Yamagami, Makoto.

    1996-01-01

    A fixed shielding member made of a radiation shielding material is constituted in perpendicular to an opening formed on radiation shielding walls. The fixed shielding member has one side opened and has other side, the upper portion and the lower portion disposed in close contact with the radiation shielding walls. Movable shielding members made of a radiation shielding material are each disposed openably on both side of the fixed shielding member. The movable shielding member has a shaft as a fulcrum on one side thereof for connecting it to the radiation shielding walls. The other side has a handle attached for opening/closing the movable shielding member. Upon access of an operator, when each one of the movable shielding members is opened/closed on every time, leakage of linear or scattered radiation can be prevented. Even when both of the movable shielding members are opened simultaneously, the fixed shielding member and the movable shielding members form labyrinth to prevent leakage of linear radioactivity. (I.N.)

  5. EBT-P gamma-ray-shielding analysis

    International Nuclear Information System (INIS)

    Gohar, Y.

    1983-01-01

    First, a one-dimensional scoping study was performed for the gamma-ray shield of the ELMO Bumpy Torus proof-of-principle device to define appropriate shielding material and determine the required shielding thickness. The dose-equivalent results are analyzed as a function of the radiation-shield thickness for different shielding options. A sensitivity analysis for the pessimistic case is given. The recommended shielding option based on the performance and cost is discussed. Next, a three-dimensional scoping study for the coil shield was performed for four different shielding options to define the heat load for each component and check the compliance with the design criterion of 10 watts maximum heat load per coil from the gamma-ray sources. Also, a detailed biological-dose survey was performed which included: (a) the dose equivalent inside and outside the building, (b) the dose equivalent from the two mazes of the building, and (c) the skyshine contribution to the dose equivalent

  6. Chemistry, transport and dry deposition of trace gases in the boundary layer over the tropical Atlantic Ocean and the Guyanas during the GABRIEL field campaign

    NARCIS (Netherlands)

    Stickler, A.; Fischer, H.; Bozem, H.; Gurk, C.; Schiller, C.; Martinez-Harder, M.; Kubistin, D.; Harder, H.; Williams, J.; Eerdekens, G.; Yassaa, N.; Ganzeveld, L.N.; Sander, R.; Lelieveld, J.

    2007-01-01

    We present a comparison of different Lagrangian and chemical box model calculations with measurement data obtained during the GABRIEL campaign over the tropical Atlantic Ocean and the Amazon rainforest in the Guyanas, October 2005. Lagrangian modelling of boundary layer (BL) air constrained by

  7. Hylid frogs from Mount Ayanganna, Guyana: new species, redescriptions, and distributional records

    Directory of Open Access Journals (Sweden)

    Ross D. MacCulloch

    2005-10-01

    Full Text Available A new species of Osteocephalus, one species of Hyla, three species of Hypsiboas and one of Myersiohyla were collected on Mount Ayanganna, a sandstone Guiana Shield tepui. Hyla warreni, Hypsiboas roraima, H. sibleszi, Myersiohyla kanaima and the new Osteocephalus were collected in high-tepui forest at 1500 m elevation, while Hypsiboas lemai, H. roraima and M. kanaima were also collected in lower montane forest at 870 m. Supplementary descriptions of adults of all species of Hyla, Hypsiboas and Myersiohyla based on the newly collected specimens are provided. Tadpoles of M. kanaima are described. The specimens from Ayanganna represent significant distributional records for several species. This is the first record of Osteocephalus as a member of the Guiana Shield high-tepui herpetofauna.

  8. Shielding plugs

    International Nuclear Information System (INIS)

    Makishima, Kenji.

    1986-01-01

    Purpose: In shielding plugs of an LMFBR type reactor, to restrain natural convection of heat in an annular space between a thermal shield layer and a shield shell, to prevent the lowering of heat-insulation performance, and to alleviate a thermal stress in a reactor container and the shield shell. Constitution: A ring-like leaf spring split in the direction of height is disposed in an annular space between a thermal shield layer and a shield shell. In consequence, the space is partitioned in the direction of height and, therefore, if axial temperature conditions and space width are the same and the space is low, the natural convection is hard to occur. Thus the rise of upper surface temperature of the shielding plugs can prevent the lowering of the heat insulation performance which will result in the increment of shielding plug cooling capacity, thereby improving reliability. In the meantime, since there is mounted an earthquake-resisting support, the thermal shield layer will move for a slight gap in case of an earthquake, being supported by the earthquake-resisting support, and the movement of the thermal shield layer is restricted, thereby maintaining integrity without increasing the stroke of the ring-like spring. (Kawakami, Y.)

  9. Shielding structure analysis for LSDS facility

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Hong Yeop; Kim, Jeong Dong; Lee, Yong Deok; Kim, Ho Dong [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    The nuclear material (Pyro, Spent nuclear fuel) itself and the target material to generate neutrons is the LSDS system for isotopic fissile assay release of high intensity neutron and gamma rays. This research was performed to shield from various strong radiation. A shielding evaluation was carried out with a facilities model of LSDS system. The MCNPX 2.5 code was used and a shielding evaluation was performed for the shielding structure and location. The radiation dose based on the hole structure and location of the wall was evaluated. The shielding evaluation was performed to satisfy the safety standard for a normal person (1 μSv/h) and to use enough interior space. The MCNPX2.5 code was used and a dose evaluation was performed for the location of the shielding material, shielding structure, and hole structure. The evaluation result differs according to the shielding material location. The dose rate was small when the shielding material was positioned at the center. The dose evaluation result regarding the location of the shielding material was applied to the facility and the shielding thickness was determined (In 50 cm + Borax 5 cm + Out 45cm). In the existing hole structure, the radiation leak is higher than the standard. A hole structure model to prevent leakage of radiation was proposed. The general public dose limit was satisfied when using the concrete reinforcement and a zigzag structure. The shielding result will be of help to the facility shielding optimization.

  10. Shielding structure analysis for LSDS facility

    International Nuclear Information System (INIS)

    Choi, Hong Yeop; Kim, Jeong Dong; Lee, Yong Deok; Kim, Ho Dong

    2014-01-01

    The nuclear material (Pyro, Spent nuclear fuel) itself and the target material to generate neutrons is the LSDS system for isotopic fissile assay release of high intensity neutron and gamma rays. This research was performed to shield from various strong radiation. A shielding evaluation was carried out with a facilities model of LSDS system. The MCNPX 2.5 code was used and a shielding evaluation was performed for the shielding structure and location. The radiation dose based on the hole structure and location of the wall was evaluated. The shielding evaluation was performed to satisfy the safety standard for a normal person (1 μSv/h) and to use enough interior space. The MCNPX2.5 code was used and a dose evaluation was performed for the location of the shielding material, shielding structure, and hole structure. The evaluation result differs according to the shielding material location. The dose rate was small when the shielding material was positioned at the center. The dose evaluation result regarding the location of the shielding material was applied to the facility and the shielding thickness was determined (In 50 cm + Borax 5 cm + Out 45cm). In the existing hole structure, the radiation leak is higher than the standard. A hole structure model to prevent leakage of radiation was proposed. The general public dose limit was satisfied when using the concrete reinforcement and a zigzag structure. The shielding result will be of help to the facility shielding optimization

  11. SHIELD 1.0: development of a shielding calculator program in diagnostic radiology; SHIELD 1.0: desenvolvimento de um programa de calculo de blindagem em radiodiagnostico

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Romulo R.; Real, Jessica V.; Luz, Renata M. da [Hospital Sao Lucas (PUCRS), Porto Alegre, RS (Brazil); Friedrich, Barbara Q.; Silva, Ana Maria Marques da, E-mail: ana.marques@pucrs.br [Pontificia Universidade Catolica do Rio Grande do Sul (PUCRS), Porto Alegre, RS (Brazil)

    2013-08-15

    In shielding calculation of radiological facilities, several parameters are required, such as occupancy, use factor, number of patients, source-barrier distance, area type (controlled and uncontrolled), radiation (primary or secondary) and material used in the barrier. The shielding design optimization requires a review of several options about the physical facility design and, mainly, the achievement of the best cost-benefit relationship for the shielding material. To facilitate the development of this kind of design, a program to calculate the shielding in diagnostic radiology was implemented, based on data and limits established by National Council on Radiation Protection and Measurements (NCRP) 147 and SVS-MS 453/98. The program was developed in C⌗ language, and presents a graphical interface for user data input and reporting capabilities. The module initially implemented, called SHIELD 1.0, refers to calculating barriers for conventional X-ray rooms. The program validation was performed by the comparison with the results of examples of shielding calculations presented in NCRP 147.

  12. A study of the electromagnetic shielding mechanisms in the GHz frequency range of graphene based composite layers

    Energy Technology Data Exchange (ETDEWEB)

    Drakakis, E. [Electrical Engineering Department, School of Engineering, Technological Educational Institute of Crete, Heraklion (Greece); Kymakis, E. [Electrical Engineering Department, School of Engineering, Technological Educational Institute of Crete, Heraklion (Greece); Center of Materials Technology and Photonics, School of Engineering, Technological Educational Institute of Crete, Heraklion (Greece); Tzagkarakis, G.; Louloudakis, D.; Katharakis, M. [Center of Materials Technology and Photonics, School of Engineering, Technological Educational Institute of Crete, Heraklion (Greece); Kenanakis, G. [Institute of Electronic Structure & Laser (IESL), Foundation for Research and Technology (FORTH) Hellas, Heraklion (Greece); Suchea, M.; Tudose, V. [Center of Materials Technology and Photonics, School of Engineering, Technological Educational Institute of Crete, Heraklion (Greece); Chemistry Faculty, “Al.I.Cuza” University of Iasi, Iasi (Romania); Koudoumas, E., E-mail: koudoumas@staff.teicrete.gr [Electrical Engineering Department, School of Engineering, Technological Educational Institute of Crete, Heraklion (Greece); Center of Materials Technology and Photonics, School of Engineering, Technological Educational Institute of Crete, Heraklion (Greece)

    2017-03-15

    Highlights: • Optimum paint contents should be chosen so that homogeneous and uniform nanocomposite layers exist exhibiting effective electromagnetic shielding. • The electromagnetic shielding in the frequency range studied comes mainly from absorption and increases with frequency. • Reflection reduces with increasing frequency, the decrease rate being smaller than that of the increase in absorption. • The shielding efficiency depends on both conductivity and thickness, the first dependence being more pronounced. - Abstract: We report on the mechanisms of the electromagnetic interference shielding effect of graphene based paint like composite layers. In particular, we studied the absorption and reflection of electromagnetic radiation in the 4–20 GHz frequency of various dispersions employing different amounts of graphene nanoplatelets, polyaniline, and poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate), special attention given on the relative contribution of each process in the shielding effect. Moreover, the influence of the composition, the thickness and the conductivity of the composite layers on the electromagnetic shielding was also examined.

  13. A study of the electromagnetic shielding mechanisms in the GHz frequency range of graphene based composite layers

    International Nuclear Information System (INIS)

    Drakakis, E.; Kymakis, E.; Tzagkarakis, G.; Louloudakis, D.; Katharakis, M.; Kenanakis, G.; Suchea, M.; Tudose, V.; Koudoumas, E.

    2017-01-01

    Highlights: • Optimum paint contents should be chosen so that homogeneous and uniform nanocomposite layers exist exhibiting effective electromagnetic shielding. • The electromagnetic shielding in the frequency range studied comes mainly from absorption and increases with frequency. • Reflection reduces with increasing frequency, the decrease rate being smaller than that of the increase in absorption. • The shielding efficiency depends on both conductivity and thickness, the first dependence being more pronounced. - Abstract: We report on the mechanisms of the electromagnetic interference shielding effect of graphene based paint like composite layers. In particular, we studied the absorption and reflection of electromagnetic radiation in the 4–20 GHz frequency of various dispersions employing different amounts of graphene nanoplatelets, polyaniline, and poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate), special attention given on the relative contribution of each process in the shielding effect. Moreover, the influence of the composition, the thickness and the conductivity of the composite layers on the electromagnetic shielding was also examined.

  14. Preparation of a basic data base for shielding design. 3

    International Nuclear Information System (INIS)

    Takemura, Morio

    1998-03-01

    With use of a standard groupwise shielding design library JSSTDL produced from the latest evaluated nuclear data library JENDL-3.2, experimental analyses for the In-Vessel Fuel Storage (IVS) Experiment and the Intermediate Heat Exchanger (IHX) Experiment were performed. The results were compared with those obtained by the same analysis method and input data using the JSDJ2 library that had been applied consistently to the JASPER experiment analyses. In general, the results obtained with JSSTDL are higher than those with JSDJ2 as were found in analyses in last two years for the Radial Shield Attenuation Experiment and the Special Materials Experiment and also the Axial Shield Experiment. The calculation-to-experiment ratios of the fast neutron flux just behind deep penetration in sodium were obtained first by these IVS and IHX experimental analyses with the JSSTDL library. However, it was confirmed not to be easy to evaluate the accuracy of sodium cross section because of its dependency on how to model the swelled sodium slabs and tanks. The analyses with JSSTDL library were verified by comparison with other analyses with another library based on JENDL-3.2. Compilation of the input data necessary for future reanalyses of important configurations in JASPER experiments, that were selected at the first stage of this study, were continued and new data were added into the computer disk holding previously accumulated data. (author)

  15. Infrared Thermography Approach for Effective Shielding Area of Field Smoke Based on Background Subtraction and Transmittance Interpolation.

    Science.gov (United States)

    Tang, Runze; Zhang, Tonglai; Chen, Yongpeng; Liang, Hao; Li, Bingyang; Zhou, Zunning

    2018-05-06

    Effective shielding area is a crucial indicator for the evaluation of the infrared smoke-obscuring effectiveness on the battlefield. The conventional methods for assessing the shielding area of the smoke screen are time-consuming and labor intensive, in addition to lacking precision. Therefore, an efficient and convincing technique for testing the effective shielding area of the smoke screen has great potential benefits in the smoke screen applications in the field trial. In this study, a thermal infrared sensor with a mid-wavelength infrared (MWIR) range of 3 to 5 μm was first used to capture the target scene images through clear as well as obscuring smoke, at regular intervals. The background subtraction in motion detection was then applied to obtain the contour of the smoke cloud at each frame. The smoke transmittance at each pixel within the smoke contour was interpolated based on the data that was collected from the image. Finally, the smoke effective shielding area was calculated, based on the accumulation of the effective shielding pixel points. One advantage of this approach is that it utilizes only one thermal infrared sensor without any other additional equipment in the field trial, which significantly contributes to the efficiency and its convenience. Experiments have been carried out to demonstrate that this approach can determine the effective shielding area of the field infrared smoke both practically and efficiently.

  16. Infrared Thermography Approach for Effective Shielding Area of Field Smoke Based on Background Subtraction and Transmittance Interpolation

    Directory of Open Access Journals (Sweden)

    Runze Tang

    2018-05-01

    Full Text Available Effective shielding area is a crucial indicator for the evaluation of the infrared smoke-obscuring effectiveness on the battlefield. The conventional methods for assessing the shielding area of the smoke screen are time-consuming and labor intensive, in addition to lacking precision. Therefore, an efficient and convincing technique for testing the effective shielding area of the smoke screen has great potential benefits in the smoke screen applications in the field trial. In this study, a thermal infrared sensor with a mid-wavelength infrared (MWIR range of 3 to 5 μm was first used to capture the target scene images through clear as well as obscuring smoke, at regular intervals. The background subtraction in motion detection was then applied to obtain the contour of the smoke cloud at each frame. The smoke transmittance at each pixel within the smoke contour was interpolated based on the data that was collected from the image. Finally, the smoke effective shielding area was calculated, based on the accumulation of the effective shielding pixel points. One advantage of this approach is that it utilizes only one thermal infrared sensor without any other additional equipment in the field trial, which significantly contributes to the efficiency and its convenience. Experiments have been carried out to demonstrate that this approach can determine the effective shielding area of the field infrared smoke both practically and efficiently.

  17. Estimating ISABELLE shielding requirements

    International Nuclear Information System (INIS)

    Stevens, A.J.; Thorndike, A.M.

    1976-01-01

    Estimates were made of the shielding thicknesses required at various points around the ISABELLE ring. Both hadron and muon requirements are considered. Radiation levels at the outside of the shield and at the BNL site boundary are kept at or below 1000 mrem per year and 5 mrem/year respectively. Muon requirements are based on the Wang formula for pion spectra, and the hadron requirements on the hadron cascade program CYLKAZ of Ranft. A muon shield thickness of 77 meters of sand is indicated outside the ring in one area, and hadron shields equivalent to from 2.7 to 5.6 meters in thickness of sand above the ring. The suggested safety allowance would increase these values to 86 meters and 4.0 to 7.2 meters respectively. There are many uncertainties in such estimates, but these last figures are considered to be rather conservative

  18. A study on the characteristics of modified and novolac type epoxy resin based neutron shielding material

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Soo Haeng; Hong, Sun Seok; Oh, Seung Chul; Do, Jae Bum [Korea Atomic Energy Research Institute, Taejon (Korea)

    1998-10-01

    Because the exposure to radiation in the nuclear facilities can be fatal to human, it is important to reduce the radiation dose level to a tolerable level. The purpose of this study is to develop highly effective neutron shielding materials for the shipping and storage cask of radioactive materials or in the nuclear/radiation facilities. In this study, we developed modified and novolac type epoxy resin based neutron shielding materials and their various material properties, including neutron shielding ability, prolonged time heat resistance, thermal and mechanical properties were evaluated experimently. (author). 31 refs., 27 figs., 16 tabs.

  19. Hot Cell Window Shielding Analysis Using MCNP

    International Nuclear Information System (INIS)

    Pope, Chad L.; Scates, Wade W.; Taylor, J. Todd

    2009-01-01

    The Idaho National Laboratory Materials and Fuels Complex nuclear facilities are undergoing a documented safety analysis upgrade. In conjunction with the upgrade effort, shielding analysis of the Fuel Conditioning Facility (FCF) hot cell windows has been conducted. This paper describes the shielding analysis methodology. Each 4-ft thick window uses nine glass slabs, an oil film between the slabs, numerous steel plates, and packed lead wool. Operations in the hot cell center on used nuclear fuel (UNF) processing. Prior to the shielding analysis, shield testing with a gamma ray source was conducted, and the windows were found to be very effective gamma shields. Despite these results, because the glass contained significant amounts of lead and little neutron absorbing material, some doubt lingered regarding the effectiveness of the windows in neutron shielding situations, such as during an accidental criticality. MCNP was selected as an analysis tool because it could model complicated geometry, and it could track gamma and neutron radiation. A bounding criticality source was developed based on the composition of the UNF. Additionally, a bounding gamma source was developed based on the fission product content of the UNF. Modeling the windows required field inspections and detailed examination of drawings and material specifications. Consistent with the shield testing results, MCNP results demonstrated that the shielding was very effective with respect to gamma radiation, and in addition, the analysis demonstrated that the shielding was also very effective during an accidental criticality.

  20. Development of neutron shielding material for cask

    International Nuclear Information System (INIS)

    Najima, K.; Ohta, H.; Ishihara, N.; Matsuoka, T.; Kuri, S.; Ohsono, K.; Hode, S.

    2001-01-01

    Since 1980's Mitsubishi Heavy Industries, Ltd (MHI) has established transport and storage cask design 'MSF series' which makes higher payload and reliability for long term storage. MSF series transport and storage cask uses new-developed neutron shielding material. This neutron shielding material has been developed for improving durability under high condition for long term. Since epoxy resin contains a lot of hydrogen and is comparatively resistant to heat, many casks employ epoxy base neutron shielding material. However, if the epoxy base neutron shielding material is used under high temperature condition for a long time, the material deteriorates and the moisture contained in it is released. The loss of moisture is in the range of several percents under more than 150 C. For this reason, our purpose was to develop a high durability epoxy base neutron shielding material which has the same self-fire-extinction property, high hydrogen content and so on as conventional. According to the long-time heating test, the weight loss of this new neutron shielding material after 5000 hours heating has been lower than 0.04% at 150 C and 0.35% at 170 C. A thermal test was also performed: a specimen of neutron shielding material covered with stainless steel was inserted in a furnace under condition of 800 C temperature for 30 minutes then was left to cool down in ambient conditions. The external view of the test piece shows that only a thin layer was carbonized

  1. Neotropical genera of Naucoridae (Hemiptera: Heteroptera: Nepomorpha): new species of Placomerus and Procryphocricos from Guyana and Venezuela.

    Science.gov (United States)

    Sites, Robert W; Camacho, Jesús

    2014-01-09

    The Neotropical fauna of saucer bugs (Naucoridae) currently includes four monotypic genera. Recent extensive collecting in Venezuela has produced three new species in two of these genera. In addition, undetermined Guyanan specimens of one of the new species were found in the United States National Museum of Natural History. Thus, described here are Placomerus obscuratus n. sp. from Guyana and Venezuela with brachypterous and macropterous hindwing forms, and two species of Procryphocricos from Venezuela. Procryphocricos quiu n. sp. is described from the brachypterous forewing form and Procryphocricos macoita n. sp. from both brachypterous and macropterous forms. Previously described species also are discussed.

  2. Comprehensive analysis of shielding effectiveness for HDPE, BPE and concrete as candidate materials for neutron shielding

    International Nuclear Information System (INIS)

    Dhang, Prosenjit; Verma, Rishi; Shyam, Anurag

    2015-01-01

    In the compact accelerator based DD neutron generator, the deuterium ions generated by the ion source are accelerated after the extraction and bombarded to a deuterated titanium target. The emitted neutrons have typical energy of ∼2.45MeV. Utilization of these compact accelerator based neutron generators of yield up to 10 9 neutron/second (DD) is under active consideration in many research laboratories for conducting active neutron interrogation experiments. Requirement of an adequately shielded laboratory is mandatory for the effective and safe utilization of these generators for intended applications. In this reference, we report the comprehensive analysis of shielding effectiveness for High Density Polyethylene (HDPE), Borated Polyethylene (BPE) and Concrete as candidate materials for neutron shielding. In shielding calculations, neutron induced scattering and absorption gamma dose has also been considered along with neutron dose. Contemporarily any material with higher hydrogenous concentration is best suited for neutron shielding. Choice of shielding material is also dominated by practical issues like economic viability and availability of space. Our computational analysis results reveal that utilization of BPE sheets results in minimum wall thickness requirement for attaining similar range of attenuation in neutron and gamma dose. The added advantage of using borated polyethylene is that it reduces the effect of both neutron and gamma dose by absorbing neutron and producing lithium and alpha particle. It has also been realized that for deciding upon optimum thickness determination of any shielding material, three important factors to be necessarily considered are: use factor, occupancy factor and work load factor. (author)

  3. Combined measurement system for double shield tunnel boring machine guidance based on optical and visual methods.

    Science.gov (United States)

    Lin, Jiarui; Gao, Kai; Gao, Yang; Wang, Zheng

    2017-10-01

    In order to detect the position of the cutting shield at the head of a double shield tunnel boring machine (TBM) during the excavation, this paper develops a combined measurement system which is mainly composed of several optical feature points, a monocular vision sensor, a laser target sensor, and a total station. The different elements of the combined system are mounted on the TBM in suitable sequence, and the position of the cutting shield in the reference total station frame is determined by coordinate transformations. Subsequently, the structure of the feature points and matching technique for them are expounded, the position measurement method based on monocular vision is presented, and the calibration methods for the unknown relationships among different parts of the system are proposed. Finally, a set of experimental platforms to simulate the double shield TBM is established, and accuracy verification experiments are conducted. Experimental results show that the mean deviation of the system is 6.8 mm, which satisfies the requirements of double shield TBM guidance.

  4. Shielding Effectiveness of a Thin Film Window

    National Research Council Canada - National Science Library

    Johnson, Eric

    1998-01-01

    .... The predicted shielding effectiveness was 29 dB based on theoretical calculations. The error analysis of the shielding effectiveness showed that this predicted value was within the measurement error...

  5. A study of the electromagnetic shielding mechanisms in the GHz frequency range of graphene based composite layers

    Science.gov (United States)

    Drakakis, E.; Kymakis, E.; Tzagkarakis, G.; Louloudakis, D.; Katharakis, M.; Kenanakis, G.; Suchea, M.; Tudose, V.; Koudoumas, E.

    2017-03-01

    We report on the mechanisms of the electromagnetic interference shielding effect of graphene based paint like composite layers. In particular, we studied the absorption and reflection of electromagnetic radiation in the 4-20 GHz frequency of various dispersions employing different amounts of graphene nanoplatelets, polyaniline, and poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate), special attention given on the relative contribution of each process in the shielding effect. Moreover, the influence of the composition, the thickness and the conductivity of the composite layers on the electromagnetic shielding was also examined.

  6. Morphometry of terrestrial shield volcanoes

    Science.gov (United States)

    Grosse, Pablo; Kervyn, Matthieu

    2018-03-01

    Shield volcanoes are described as low-angle edifices built primarily by the accumulation of successive lava flows. This generic view of shield volcano morphology is based on a limited number of monogenetic shields from Iceland and Mexico, and a small set of large oceanic islands (Hawaii, Galápagos). Here, the morphometry of 158 monogenetic and polygenetic shield volcanoes is analyzed quantitatively from 90-meter resolution SRTM DEMs using the MORVOLC algorithm. An additional set of 24 lava-dominated 'shield-like' volcanoes, considered so far as stratovolcanoes, are documented for comparison. Results show that there is a large variation in shield size (volumes from 0.1 to > 1000 km3), profile shape (height/basal width (H/WB) ratios mostly from 0.01 to 0.1), flank slope gradients (average slopes mostly from 1° to 15°), elongation and summit truncation. Although there is no clear-cut morphometric difference between shield volcanoes and stratovolcanoes, an approximate threshold can be drawn at 12° average slope and 0.10 H/WB ratio. Principal component analysis of the obtained database enables to identify four key morphometric descriptors: size, steepness, plan shape and truncation. Hierarchical cluster analysis of these descriptors results in 12 end-member shield types, with intermediate cases defining a continuum of morphologies. The shield types can be linked in terms of growth stages and shape evolution, related to (1) magma composition and rheology, effusion rate and lava/pyroclast ratio, which will condition edifice steepness; (2) spatial distribution of vents, in turn related to the magmatic feeding system and the tectonic framework, which will control edifice plan shape; and (3) caldera formation, which will condition edifice truncation.

  7. Innovative technologies for Faraday shield cooling

    International Nuclear Information System (INIS)

    Rosenfeld, J.H.; Lindemuth, J.E.; North, M.T.; Goulding, R.H.

    1995-01-01

    Alternative advanced technologies are being evaluated for use in cooling the Faraday shields used for protection of ion cyclotron range of frequencies (ICR) antennae in Tokamaks. Two approaches currently under evaluation include heat pipe cooling and gas cooling. A Monel/water heat pipe cooled Faraday shield has been successfully demonstrated. Heat pipe cooling offers the advantage of reducing the amount of water discharged into the Tokamak in the event of a tube weld failure. The device was recently tested on an antenna at Oak Ridge National Laboratory. The heat pipe design uses inclined water heat pipes with warm water condensers located outside of the plasma chamber. This approach can passively remove absorbed heat fluxes in excess of 200 W/cm 2 ;. Helium-cooled Faraday shields are also being evaluated. This approach offers the advantage of no liquid discharge into the Tokamak in the event of a tube failure. Innovative internal cooling structures based on porous metal cooling are being used to develop a helium-cooled Faraday shield structure. This approach can dissipate the high heat fluxes typical of Faraday shield applications while minimizing the required helium blower power. Preliminary analysis shows that nominal helium flow and pressure drop can sufficiently cool a Faraday shield in typical applications. Plans are in progress to fabricate and test prototype hardware based on this approach

  8. Electromagnetic shielding

    International Nuclear Information System (INIS)

    Tzeng, Wen-Shian V.

    1991-01-01

    Electromagnetic interference (EMI) shielding materials are well known in the art in forms such as gaskets, caulking compounds, adhesives, coatings and the like for a variety of EMI shielding purposes. In the past, where high shielding performance is necessary, EMI shielding has tended to use silver particles or silver coated copper particles dispersed in a resin binder. More recently, aluminum core silver coated particles have been used to reduce costs while maintaining good electrical and physical properties. (author). 8 figs

  9. Synthesis of ferrofluid based nanoarchitectured polypyrrole composites and its application for electromagnetic shielding

    Energy Technology Data Exchange (ETDEWEB)

    Varshney, Swati [Polymeric and Soft Materials Section, National Physical Laboratory (CSIR), New Delhi 110012 (India); Department of Chemistry, Delhi Institute of Tool Engineering, Okhla, New Delhi 110020 (India); Amity Institute of Advanced Research and Studies, Materials and Devices, AIARS (M and D), Amity University, Noida, UP 201303 (India); Ohlan, Anil [Department of Physics, M.D. University, Rohtak, Haryana 124001 (India); Jain, V.K. [Amity Institute of Advanced Research and Studies, Materials and Devices, AIARS (M and D), Amity University, Noida, UP 201303 (India); Dutta, V.P. [Department of Chemistry, Delhi Institute of Tool Engineering, Okhla, New Delhi 110020 (India); Dhawan, S.K., E-mail: skdhawan@mail.nplindia.ernet.in [Polymeric and Soft Materials Section, National Physical Laboratory (CSIR), New Delhi 110012 (India)

    2014-01-15

    The monodispersion of magnetic nanoparticles in conducting polymer is the prerequisite to make a high quality composite for tunable electromagnetic interference (EMI) shielding. To meet this challenge, we have designed and synthesized ferrofluid based nanoarchitectured polypyrrole composites containing Fe{sub 3}O{sub 4} (8–12 nm) via in situ oxidative polymerization. To tune the microwave signals, polypyrrole composites (PFF) with different monomer/ferrofluid weight ratios have been prepared and characterized in microwave frequency domain. A maximum shielding effectiveness value of SE{sub A(max)} = 20.4 dB (∼99% attenuation) due to the absorption of microwave has been observed in the frequency range of 12.4–18 GHz and attenuation level varied with ferrofluid loading. The electrical conductivity of PFF composite is of the order of 10{sup −2} S cm{sup −1} order and having superparamagnetic nature with saturation magnetization (M{sub s}) of 5.5 emu g{sup −1}. The lightweight PFF composites with high attenuations can provide full control over the atomic structure and are favorable for the practical EMI shielding application for commercial electronic appliances. - Highlights: • Aqueous ferrofluid has been incorporated in polypyrrole matrix leads to PFF nanocomposites. • PFF composites shows conductivity of the order of 10{sup −2} S cm{sup −1} and saturation magnetization of 5.5 emu g{sup −1}. • Shielding effectiveness of 23.5 dB (SE{sub A} ∼ 20.4 dB and SE{sub R} ∼ 3.1 dB) has been achieved. • Shielding effectiveness depends on the ferrofluid loading.

  10. Survivor shielding. Part C. Improvements in terrain shielding

    International Nuclear Information System (INIS)

    Egbert, Stephen D.; Kaul, Dean C.; Roberts, James A.; Kerr, George D.

    2005-01-01

    A number of atomic-bomb survivors were affected by shielding provided by terrain features. These terrain features can be a small hill, affecting one or two houses, or a high mountain that shields large neighborhoods. In the survivor dosimetry system, terrain shielding can be described by a transmission factor (TF), which is the ratio between the dose with and without the terrain present. The terrain TF typically ranges between 0.1 and 1.0. After DS86 was implemented at RERF, the terrain shielding categories were examined and found to either have a bias or an excessive uncertainty that could readily be removed. In 1989, an improvement in the terrain model was implemented at RERF in the revised DS86 code, but the documentation was not published. It is now presented in this section. The solution to the terrain shielding in front of a house is described in this section. The problem of terrain shielding of survivors behind Hijiyama mountain at Hiroshima and Konpirasan mountain at Nagasaki has also been recognized, and a solution to this problem has been included in DS02. (author)

  11. Mechanical performance optimization of neutron shielding material based on short carbon fiber reinforced B4C/epoxy resin

    International Nuclear Information System (INIS)

    Wang Peng; Tang Xiaobin; Chen Feida; Chen Da

    2013-01-01

    To satisfy engineering requirements for mechanics performance of neutron shielding material, short carbon fiber was used to reinforce the traditional containing B 4 C neutron shielding material and effects of fiber content, length and surface treatment to mechanics performance of material was discussed. Based on Americium-Beryllium neutron source, material's neutron shielding performance was tested. The result of experiment prove that tensile strength of material which the quality ratio of resin and fiber is 5:1 is comparatively excellent for 10wt% B 4 C of carbon fiber reinforced epoxy resin. The tensile properties of material change little with the fiber length ranged from 3-10 mm The treatment of fiber surface with silane coupling agent KH-550 can increase the tensile properties of materials by 20% compared with the untreated of that. A result of shielding experiment that the novel neutron shielding material can satisfy the neutron shielding requirements can be obtained by comparing with B 4 C/polypropylene materials. The material has good mechanical properties and wide application prospect. (authors)

  12. Shielding Design and Radiation Shielding Evaluation for LSDS System Facility

    International Nuclear Information System (INIS)

    Kim, Younggook; Kim, Jeongdong; Lee, Yongdeok

    2015-01-01

    As the system characteristics, the target in the spectrometer emits approximately 1012 neutrons/s. To efficiently shield the neutron, the shielding door designs are proposed for the LSDS system through a comparison of the direct shield and maze designs. Hence, to guarantee the radiation safety for the facility, the door design is a compulsory course of the development of the LSDS system. To improve the shielding rates, 250x250 covering structure was added as a subsidiary around the spectrometer. In this study, the evaluations of the suggested shielding designs were conducted using MCNP code. The suggested door design and covering structures can shield the neutron efficiently, thus all evaluations of all conditions are satisfied within the public dose limits. From the Monte Carlo code simulation, Resin(Indoor type) and Tungsten(Outdoor type) were selected as the shielding door materials. From a comparative evaluation of the door thickness, In and Out door thickness was selected 50 cm

  13. Final report of Shield System Trade Study. Volume II. WANL support activities for shielding trade study

    International Nuclear Information System (INIS)

    1970-07-01

    Based on the trades made within this study BATH (mixture of B 4 C, aluminum and TiH 1 . 8 ) was selected as the internal shield material. Borated titanium hydride can also meet the criteria with a competitive weight but was rejected because of schedular constraints. A baseline internal shield design was accomplished. This design resulted in a single internal shield weighing about 3300 lb for both manned and unmanned missions. WANL checks on ANSC calculations are generally in agreement, but with some difference in the prediction of the effectiveness of the Boral liner. All of the alternate NSS concepts in the system weight reduction program were rejected. While some did save shield weight, they complicated the NSS design to an unacceptable degree. Studies were made of the feasibility of manual maintenance of NSS components outside of the pressure vessel. The requirements of the NSS components located forward of the internal shield were considered from a thermal and radiation damage standpoint. (auth)

  14. Gravity Scaling of a Power Reactor Water Shield

    International Nuclear Information System (INIS)

    Reid, Robert S.; Pearson, J. Boise

    2008-01-01

    Water based reactor shielding is being considered as an affordable option for potential use on initial lunar surface reactor power systems. Heat dissipation in the shield from nuclear sources must be rejected by an auxillary thermal hydraulic cooling system. The mechanism for transferring heat through the shield is natural convection between the core surface and an array of thermosyphon radiator elements. Natural convection in a 100 kWt lunar surface reactor shield design has been previously evaluated at lower power levels (Pearson, 2006). The current baseline assumes that 5.5 kW are dissipated in the water shield, the preponderance on the core surface, but with some volumetric heating in the naturally circulating water as well. This power is rejected by a radiator located above the shield with a surface temperature of 370 K. A similarity analysis on a water-based reactor shield is presented examining the effect of gravity on free convection between a radiation shield inner vessel and a radiation shield outer vessel boundaries. Two approaches established similarity: 1) direct scaling of Rayleigh number equates gravity-surface heat flux products, 2) temperature difference between the wall and thermal boundary layer held constant on Earth and the Moon. Nussult number for natural convection (laminar and turbulent) is assumed of form Nu = CRa n . These combined results estimate similarity conditions under Earth and Lunar gravities. The influence of reduced gravity on the performance of thermosyphon heat pipes is also examined

  15. Topogram-based tube current modulation of head computed tomography for optimizing image quality while protecting the eye lens with shielding.

    Science.gov (United States)

    Lin, Ming-Fang; Chen, Chia-Yuen; Lee, Yuan-Hao; Li, Chia-Wei; Gerweck, Leo E; Wang, Hao; Chan, Wing P

    2018-01-01

    Background Multiple rounds of head computed tomography (CT) scans increase the risk of radiation-induced lens opacification. Purpose To investigate the effects of CT eye shielding and topogram-based tube current modulation (TCM) on the radiation dose received by the lens and the image quality of nasal and periorbital imaging. Material and Methods An anthropomorphic phantom was CT-scanned using either automatic tube current modulation or a fixed tube current. The lens radiation dose was estimated using cropped Gafchromic films irradiated with or without a shield over the orbit. Image quality, assessed using regions of interest drawn on the bilateral extraorbital areas and the nasal bone with a water-based marker, was evaluated using both a signal-to-noise ratio (SNR) and contrast-noise ratio (CNR). Two CT specialists independently assessed image artifacts using a three-point Likert scale. Results The estimated radiation dose received by the lens was significantly lower when barium sulfate or bismuth-antimony shields were used in conjunction with a fixed tube current (22.0% and 35.6% reduction, respectively). Topogram-based TCM mitigated the beam hardening-associated artifacts of bismuth-antimony and barium sulfate shields. This increased the SNR by 21.6% in the extraorbital region and the CNR by 7.2% between the nasal bones and extraorbital regions. The combination of topogram-based TCM and barium sulfate or bismuth-antimony shields reduced lens doses by 12.2% and 27.2%, respectively. Conclusion Image artifacts induced by the bismuth-antimony shield at a fixed tube current for lenticular radioprotection were significantly reduced by topogram-based TCM, which increased the SNR of the anthropomorphic nasal bones and periorbital tissues.

  16. Secondary gamma-ray data for shielding calculation

    International Nuclear Information System (INIS)

    Miyasaka, Sunichi

    1979-01-01

    In deep penetration transport calculations, the integral design parameters is determined mainly by secondary particles which are produced by interactions of the primary radiation with materials. The shield thickness and the biological dose rate at a given point of a bulk shield are determined from the contribution from secondary gamma rays. The heat generation and the radiation damage in the structural and shield materials depend strongly on the secondary gamma rays. In this paper, the status of the secondary gamma ray data and its further problems are described from the viewpoint of shield design. The secondary gamma-ray data in ENDF/B-IV and POPOP4 are also discussed based on the test calculations made for several shield assemblies. (author)

  17. Studies of ionizing radiation shielding effectiveness of silica-based commercial glasses used in Bangladeshi dwellings

    Science.gov (United States)

    Yasmin, Sabina; Barua, Bijoy Sonker; Khandaker, Mayeen Uddin; Chowdhury, Faruque-Uz-Zaman; Rashid, Md. Abdur; Bradley, David A.; Olatunji, Michael Adekunle; Kamal, Masud

    2018-06-01

    Following the rapid growing economy, the Bangladeshi dwellers are replacing their traditional (mud-, bamboo-, and wood-based) houses to modern multistoried buildings, where different types of glasses are being used as decorative as well as structural materials due to their various advantageous properties. In this study, we inquire the protective and dosimetric capability of commercial glasses for ionizing radiation. Four branded glass samples (PHP-Bangladesh, Osmania-Bangladesh, Nasir-Bangladesh, and Rider-China) of same thickness and color but different elemental weight fractions were analyzed for shielding and dosimetric properties. The chemical composition of the studied material was evaluated by EDX technique. A well-shielded HPGe γ-ray spectrometer combined with associated electronics was used to evaluate the attenuation coefficients of the studied materials for 59 keV, 661 keV, 1173 keV and 1332 keV photon energies. A number of shielding parameters- half value layer (HVL), radiation protection efficiency (RPE) and effective atomic number (Zeff) were also evaluated. The data were compared with the available literature (where applicable) to understand its shielding capability relative to the standard materials such as lead. Among the studied brands, Rider (China) shows relatively better indices to be used as ionizing radiation shielding material. The obtained, Zeff of the studied glass samples showed comparable values to the TLD-200 dosimeter, thus considered suitable for environmental radiation monitoring purposes.

  18. Electromagnetic shielding formulae

    International Nuclear Information System (INIS)

    Dahlberg, E.

    1979-02-01

    This addendum to an earlier collection of electromagnetic shielding formulae (TRITA-EPP-75-27) contains simple transfer matrices suitable for calculating the quasistatic shielding efficiency for multiple transverse-field and axial-field cylindrical and spherical shields, as well as for estimating leakage fields from long coaxial cables and the normal-incidence transmission of a plane wave through a multiple plane shield. The differences and similarities between these cases are illustrated by means of equivalent circuits and transmission line analogies. The addendum also includes a discussion of a possible heuristic improvement of some shielding formulae. (author)

  19. Shielding wall for thermonuclear device

    International Nuclear Information System (INIS)

    Uchida, Takaho.

    1989-01-01

    This invention concerns shielding walls opposing to plasmas of a thermonuclear device and it is an object thereof to conduct reactor operation with no troubles even if a portion of shielding wall tiles should be damaged. That is, the shielding wall tiles are constituted as a dual layer structure in which the lower base tiles are connected by means of bolts to first walls. Further, the upper surface tiles are bolt-connected to the layer base tiles. In this structure, the plasma thermal loads are directly received by the surface layer tiles and heat is conducted by means of conduction and radiation to the underlying base tiles and the first walls. Even upon occurrence of destruction accidents to the surface layer tiles caused by incident heat or electromagnetic force upon elimination of plasmas, since the underlying base tiles remain as they are, the first walls constituted with stainless steels, etc. are not directly exposed to the plasmas. Accordingly, the integrity of the first walls having cooling channels can be maintained and sputtering intrusion of atoms of high atom number into the plasmas can be prevented. (I.S.)

  20. Shield cost minimization using SWAN

    International Nuclear Information System (INIS)

    Watkins, E.F.; Annese, C.E.; Greenspan, E.

    1993-01-01

    The common approach to the search for minimum cost shield designs is open-quotes trial-and-errorclose quotes; it proceeds as follows: 1. Based on prior experience and intuition, divide the shield into zones and assume their composition. 2. Solve the transport equation and calculate the relevant performance characteristics. 3. Change the composition or the geometry of one or a few of the zones and repeat step 2. 4. Repeat step 3 many times until the shield design appears to be optimal. 5. Select a different set of constituents and repeat steps 2,3, and 4. 6. Repeate step 5 a few or many times until the designer can point to the most cost-effective design

  1. Current status of methods for shielding analysis

    International Nuclear Information System (INIS)

    Engle, W.W.

    1980-01-01

    Current methods used in shielding analysis and recent improvements in those methods are discussed. The status of methods development is discussed based on needs cited at the 1977 International Conference on Reactor Shielding. Additional areas where methods development is needed are discussed

  2. Heavy metal oxide glasses as gamma rays shielding material

    International Nuclear Information System (INIS)

    Kaur, Preet; Singh, Devinder; Singh, Tejbir

    2016-01-01

    The gamma rays shielding parameters for heavy metal oxide glasses and concrete samples are comparable. However, the transparent nature of glasses provides additional feature to visualize inside the shielding material. Hence, different researchers had contributed in computing/measuring different shielding parameters for different configurations of heavy metal oxide glass systems. In the present work, a detailed study on different heavy metal (_5_6Ba, _6_4Gd, _8_2Pb, _8_3Bi) oxide glasses has been presented on the basis of different gamma rays shielding parameters as reported by different researchers in the recent years. It has been observed that among the selected heavy metal oxide glass systems, Bismuth based glasses provide better gamma rays shielding. Hence, Bismuth based glasses can be better substitute to concrete walls at nuclear reactor sites and nuclear labs.

  3. Heavy metal oxide glasses as gamma rays shielding material

    Energy Technology Data Exchange (ETDEWEB)

    Kaur, Preet; Singh, Devinder; Singh, Tejbir, E-mail: dr.tejbir@gmail.com

    2016-10-15

    The gamma rays shielding parameters for heavy metal oxide glasses and concrete samples are comparable. However, the transparent nature of glasses provides additional feature to visualize inside the shielding material. Hence, different researchers had contributed in computing/measuring different shielding parameters for different configurations of heavy metal oxide glass systems. In the present work, a detailed study on different heavy metal ({sub 56}Ba, {sub 64}Gd, {sub 82}Pb, {sub 83}Bi) oxide glasses has been presented on the basis of different gamma rays shielding parameters as reported by different researchers in the recent years. It has been observed that among the selected heavy metal oxide glass systems, Bismuth based glasses provide better gamma rays shielding. Hence, Bismuth based glasses can be better substitute to concrete walls at nuclear reactor sites and nuclear labs.

  4. Analysis of Shield Construction in Spherical Weathered Granite Development Area

    Science.gov (United States)

    Cao, Quan; Li, Peigang; Gong, Shuhua

    2018-01-01

    The distribution of spherical weathered bodies (commonly known as "boulder") in the granite development area directly affects the shield construction of urban rail transit engineering. This paper is based on the case of shield construction of granite globular development area in Southern China area, the parameter control in shield machine selection and shield advancing during the shield tunneling in this special geological environment is analyzed. And it is suggested that shield machine should be selected for shield construction of granite spherical weathered zone. Driving speed, cutter torque, shield machine thrust, the amount of penetration and the speed of the cutter head of shield machine should be controlled when driving the boulder formation, in order to achieve smooth excavation and reduce the disturbance to the formation.

  5. Technology transfer and development: a preliminary look at Chinese technology in Guyana

    Energy Technology Data Exchange (ETDEWEB)

    Long, F

    1982-05-01

    Technology is regarded as a vital ingredient for development. Since developing countries can hardly fill their technological requirements indigenously, such countries tend to acquire the bulk of technology applied to their production systems from abroad. However, the transfer of technology tends to be associated with a series of problems: foreign exchange, inappropriateness, the generation of limited inter-sectorial linkages, limited use of raw materials, and other inputs associated with technology dependency. The study points to the fact that technology transfer need not necessarily be associated with the disadvantages identified in the literature. The study which essentially looks at the use of Chinese technology in clay-brick manufacturing in Guyana, shows that the country was able to reap several development benefits from the technology-transfer arrangement. At the same time, certain problems arising from the technology-transfer package such as the transfer of critical skills in key areas of production, and maintenance and servicing, are discussed. But these, the author argues, are not a function of restrictive conditions found in technology-transfer clauses, but rather of improper technology-transfer management. 2 tables.

  6. Is lead shielding of patients necessary during fluoroscopic procedures? A study based on kyphoplasty

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Joshua R.; Marsh, Rebecca M.; Silosky, Michael S. [University of Colorado School of Medicine, Department of Radiology, Aurora, CO (United States)

    2018-01-15

    To determine the benefits, risks, and limitations associated with wrapping a patient with lead shielding during fluoroscopy-guided kyphoplasty procedures as a way to reduce operator radiation exposure. An anthropomorphic phantom was used to mimic a patient undergoing a kyphoplasty procedure under fluoroscopic guidance. Radiation measurements of the air kerma rate (AKR) were made at several locations and under various experimental conditions. First, AKR was measured at various angles along the horizontal plane of the phantom and at varying distances from the phantom, both with and without a lead apron wrapped around the lower portion of the phantom (referred to here as phantom shielding). Second, the effect of an operator's apron was simulated by suspending a lead apron between the phantom and the measurement device. AKR was measured for the four shielding conditions - phantom shielding only, operator apron only, both phantom shielding and operator apron, and no shielding. Third, AKR measurements were made at various heights and with varying C-arm angle. At all locations, the phantom shielding provided no substantial protection beyond that provided by an operator's own lead apron. Phantom shielding did not reduce AKR at a height comparable to that of an operator's head. Previous reports of using patient shielding to reduce operator exposure fail to consider the role of an operator's own lead apron in radiation protection. For an operator wearing appropriate personal lead apparel, patient shielding provides no substantial reduction in operator dose. (orig.)

  7. Is lead shielding of patients necessary during fluoroscopic procedures? A study based on kyphoplasty

    International Nuclear Information System (INIS)

    Smith, Joshua R.; Marsh, Rebecca M.; Silosky, Michael S.

    2018-01-01

    To determine the benefits, risks, and limitations associated with wrapping a patient with lead shielding during fluoroscopy-guided kyphoplasty procedures as a way to reduce operator radiation exposure. An anthropomorphic phantom was used to mimic a patient undergoing a kyphoplasty procedure under fluoroscopic guidance. Radiation measurements of the air kerma rate (AKR) were made at several locations and under various experimental conditions. First, AKR was measured at various angles along the horizontal plane of the phantom and at varying distances from the phantom, both with and without a lead apron wrapped around the lower portion of the phantom (referred to here as phantom shielding). Second, the effect of an operator's apron was simulated by suspending a lead apron between the phantom and the measurement device. AKR was measured for the four shielding conditions - phantom shielding only, operator apron only, both phantom shielding and operator apron, and no shielding. Third, AKR measurements were made at various heights and with varying C-arm angle. At all locations, the phantom shielding provided no substantial protection beyond that provided by an operator's own lead apron. Phantom shielding did not reduce AKR at a height comparable to that of an operator's head. Previous reports of using patient shielding to reduce operator exposure fail to consider the role of an operator's own lead apron in radiation protection. For an operator wearing appropriate personal lead apparel, patient shielding provides no substantial reduction in operator dose. (orig.)

  8. Shield design development of nuclear propulsion merchant ship

    International Nuclear Information System (INIS)

    Tanaka, Yoshihisa

    1975-01-01

    Shielding design both in Japan and abroad for nuclear propulsion merchant ships is explained, with emphasis on the various technological problems having occurred in the shield design for one-body type and separate type LWRs as conceptual design. The following matters are described: the peculiarities of the design as compared with the case of land-based nuclear reactors, problems in the design standards of shielding, the present status and development of the design methods, and the instances of the design; thereby, the trends of shielding design are disclosed. The following matters are pointed out: Importance of the optimum design, of shielding, significance of radiation streaming through large voids, activation of the secondary water in built-in type steam generators, and the need of the guides for shield design. (Mori, K.)

  9. Adaptive algorithms for a self-shielding wavelet-based Galerkin method

    International Nuclear Information System (INIS)

    Fournier, D.; Le Tellier, R.

    2009-01-01

    The treatment of the energy variable in deterministic neutron transport methods is based on a multigroup discretization, considering the flux and cross-sections to be constant within a group. In this case, a self-shielding calculation is mandatory to correct sections of resonant isotopes. In this paper, a different approach based on a finite element discretization on a wavelet basis is used. We propose adaptive algorithms constructed from error estimates. Such an approach is applied to within-group scattering source iterations. A first implementation is presented in the special case of the fine structure equation for an infinite homogeneous medium. Extension to spatially-dependent cases is discussed. (authors)

  10. Shielding member for thermonuclear device

    Energy Technology Data Exchange (ETDEWEB)

    Onozuka, Masanori

    1997-06-30

    In a thermonuclear device for shielding fast neutrons by shielding members disposed in a shielding vessel (vacuum vessel and structures such as a blanket disposed in the vacuum vessel), the shielding member comprises a large number of shielding wires formed fine and short so as to have elasticity. The shielding wires are sealed in a shielding vessel together with water, and when the width of the shielding vessel is changed, the shielding wires follow after the change of the width while elastically deforming in the shielding vessel, so that great stress and deformation are not formed thereby enabling to improve reliability. In addition, the length, the diameter and the shape of each of the shielding wires can be selected in accordance with the shielding space of the shielding vessel. Even if the shape of the shielding vessel is complicated, the shielding wires can be inserted easily. Accordingly, the filling rate of the shielding members can be changed easily. It can be produced more easily compared with a conventional spherical pebbles. It can be produced more easily than existent spherical shielding pebbles thereby enabling to reduce the production cost. (N.H.)

  11. Survivor shielding. Part A. Nagasaki factory worker shielding

    International Nuclear Information System (INIS)

    Santoro, Robert T.; Barnes, John M.; Azmy, Yousry Y.; Kerr, George D.; Egbert, Stephen D.; Cullings, Harry M.

    2005-01-01

    Recent investigations based on conventional chromosome aberration data by the RERF suggest that the DS86 doses received by many Nagasaki factory workers may have been overestimated by as much as 40% relative to those for other survivors in Japanese-type houses and other shielding configurations (Kodama et al. 2001). Since the factory workers represent about 25% of the Nagasaki survivors with DS86 doses in excess of 0.5 Gy (50 rad), systematic errors in their dose estimates can have a major impact on the risk coefficients from RERF studies. The factory worker doses may have been overestimated for a number of reasons. The calculation techniques, including the factory building modeling, weapon source spectra and cross-section data used in the DS86 shielding calculations were not detailed enough to replicate actual conditions. The models used did not take into account local shielding provided by machinery, tools, and the internal structure in the buildings. In addition, changes in the disposition of shielding following collapse of the building by the blast wave were not considered. The location of large factory complexes may be uncertain, causing large numbers of factory survivors, correctly located relative to each other, to be uniformly too close to the hypocenter. Any or all of these reasons are sufficient to result in an overestimate of the factory worker doses. During the DS02 studies, factory worker doses have been reassessed by more carefully modeling the factory buildings, incorporating improved radiation transport methods and cross-section data and using the most recent bomb leakage spectra (Chapter 2). Two-dimensional discrete ordinates calculations were carried out initially to estimate the effects of workbenches and tools on worker doses to determine if the inclusion of these components would, in fact, reduce the dose by amounts consistent with the RERF observations (Kodama et al. 2001). (author)

  12. Preparation of a basic data base for shielding design. 4

    International Nuclear Information System (INIS)

    Nakao, Makoto; Takemura, Morio

    1999-03-01

    With use of a standard groupwise shielding design library JSSTDL produced from the latest evaluated nuclear data library JENDL-3.2, experimental analyses for the JASPER experiments were performed. In order to verify the new version of JSSTDL, whose cross sections of thermal energy region was updated, the polyethylene transmission experiments of the Special Materials Experiment was analysed again, and also zirconium transmission experiment of the Experiment was newly analysed. JSSTDL was applied to the analysis of neutron multiplicative region of the in-vessel fuel storage mockup configurations in the IVS Experiment. Also it was applied to the analyses of neutron streaming effect through the mockup of sodium window in B 4 C shield in the Flux Monitor Experiment and also the mockup of narrow gaps in thick concrete shield in the Gap streaming Experiment. The results were compared with those obtained by the same analysis method and input data using the JSDJ2 library that had been applied consistently to the JASPER experiment analyses. Although the analysis with the new version of JSSTDL resulted in a little reduction of overestimation in the polyethylene transmission configuration, the results obtained with JSSTDL are, in general, higher than those with JSDJ2 as had been found in analyses in preceding years for the Radial Shield Attenuation Experiment, the Axial Shield Experiment, the Intermediate Heat Exchanger Experiment and so on. Compilation of the input data necessary for future reanalyses of important configurations in JASPER experiments, that were selected at the first stage of this study, were continued and new data were added into the computer disk holding previously accumulated data. (author)

  13. A contribution to shielding effectiveness analysis of shielded tents

    Directory of Open Access Journals (Sweden)

    Vranić Zoran M.

    2004-01-01

    Full Text Available An analysis of shielding effectiveness (SE of the shielded tents made of the metallised fabrics is given. First, two electromagnetic characteristic fundamental for coupling through electrically thin shield, the skin depth break frequency and the surface resistance or transfer impedance, is defined and analyzed. Then, the transfer function and the SE are analyzed regarding to the frequency range of interest to the Electromagnetic Compatibility (EMC Community.

  14. In-Plane Shielding for CT: Effect of Off-Centering, Automatic Exposure Control and Shield-to-Surface Distance

    Energy Technology Data Exchange (ETDEWEB)

    Kalra, Mannudeep K.; Dang, Pragya; Singh, Sarabjeet; Saini, Sanjay; Shepard, Jo Anne O. [Massachusetts General Hospital, Boston (United States)

    2009-04-15

    To assess effects of off-centering, automatic exposure control, and padding on attenuation values, noise, and radiation dose when using in-plane bismuth-based shields for CT scanning. A 30 cm anthropomorphic chest phantom was scanned on a 64-multidetector CT, with the center of the phantom aligned to the gantry isocenter. Scanning was repeated after placing a bismuth breast shield on the anterior surface with no gap and with 1, 2, and 6 cm of padding between the shield and the phantom surface. The 'shielded' phantom was also scanned with combined modulation and off-centering of the phantom at 2 cm, 4 cm and 6 cm below the gantry isocenter. CT numbers, noise, and surface radiation dose were measured. The data were analyzed using an analysis of variance. The in-plane shield was not associated with any significant increment for the surface dose or CT dose index volume, which was achieved by comparing the radiation dose measured by combined modulation technique to the fixed mAs (p > 0.05). Irrespective of the gap or the surface CT numbers, surface noise increased to a larger extent compared to Hounsfield unit (HU) (0-6 cm, 26-55%) and noise (0-6 cm, 30-40%) in the center. With off-centering, in-plane shielding devices are associated with less dose savings, although dose reduction was still higher than in the absence of shielding (0 cm off-center, 90% dose reduction; 2 cm, 61%) (p < 0.0001). Streak artifacts were noted at 0 cm and 1 cm gaps but not at 2 cm and 6 cm gaps of shielding to the surface distances. In-plane shields are associated with greater image noise, artificially increased attenuation values, and streak artifacts. However, shields reduce radiation dose regardless of the extent of off-centering. Automatic exposure control did not increase radiation dose when using a shield.

  15. Comparative evaluation of structural integrity for ITER blanket shield block based on SDC-IC and ASME code

    Energy Technology Data Exchange (ETDEWEB)

    Shim, Hee-Jin [ITER Korea, National Fusion Research Institute, 169-148 Gwahak-Ro, Yuseong-Gu, Daejeon (Korea, Republic of); Ha, Min-Su, E-mail: msha12@nfri.re.kr [ITER Korea, National Fusion Research Institute, 169-148 Gwahak-Ro, Yuseong-Gu, Daejeon (Korea, Republic of); Kim, Sa-Woong; Jung, Hun-Chea [ITER Korea, National Fusion Research Institute, 169-148 Gwahak-Ro, Yuseong-Gu, Daejeon (Korea, Republic of); Kim, Duck-Hoi [ITER Organization, Route de Vinon sur Verdon - CS 90046, 13067 Sant Paul Lez Durance (France)

    2016-11-01

    Highlights: • The procedure of structural integrity and fatigue assessment was described. • Case studies were performed according to both SDC-IC and ASME Sec. • III codes The conservatism of the ASME code was demonstrated. • The study only covers the specifically comparable case about fatigue usage factor. - Abstract: The ITER blanket Shield Block is a bulk structure to absorb radiation and to provide thermal shielding to vacuum vessel and external vessel components, therefore the most significant load for Shield Block is the thermal load. In the previous study, the thermo-mechanical analysis has been performed under the inductive operation as representative loading condition. And the fatigue evaluations were conducted to assure structural integrity for Shield Block according to Structural Design Criteria for In-vessel Components (SDC-IC) which provided by ITER Organization (IO) based on the code of RCC-MR. Generally, ASME code (especially, B&PV Sec. III) is widely applied for design of nuclear components, and is usually well known as more conservative than other specific codes. For the view point of the fatigue assessment, ASME code is very conservative compared with SDC-IC in terms of the reflected K{sub e} factor, design fatigue curve and other factors. Therefore, an accurate fatigue assessment comparison is needed to measure of conservatism. The purpose of this study is to provide the fatigue usage comparison resulting from the specified operating conditions shall be evaluated for Shield Block based on both SDC-IC and ASME code, and to discuss the conservatism of the results.

  16. Comparative evaluation of structural integrity for ITER blanket shield block based on SDC-IC and ASME code

    International Nuclear Information System (INIS)

    Shim, Hee-Jin; Ha, Min-Su; Kim, Sa-Woong; Jung, Hun-Chea; Kim, Duck-Hoi

    2016-01-01

    Highlights: • The procedure of structural integrity and fatigue assessment was described. • Case studies were performed according to both SDC-IC and ASME Sec. • III codes The conservatism of the ASME code was demonstrated. • The study only covers the specifically comparable case about fatigue usage factor. - Abstract: The ITER blanket Shield Block is a bulk structure to absorb radiation and to provide thermal shielding to vacuum vessel and external vessel components, therefore the most significant load for Shield Block is the thermal load. In the previous study, the thermo-mechanical analysis has been performed under the inductive operation as representative loading condition. And the fatigue evaluations were conducted to assure structural integrity for Shield Block according to Structural Design Criteria for In-vessel Components (SDC-IC) which provided by ITER Organization (IO) based on the code of RCC-MR. Generally, ASME code (especially, B&PV Sec. III) is widely applied for design of nuclear components, and is usually well known as more conservative than other specific codes. For the view point of the fatigue assessment, ASME code is very conservative compared with SDC-IC in terms of the reflected K_e factor, design fatigue curve and other factors. Therefore, an accurate fatigue assessment comparison is needed to measure of conservatism. The purpose of this study is to provide the fatigue usage comparison resulting from the specified operating conditions shall be evaluated for Shield Block based on both SDC-IC and ASME code, and to discuss the conservatism of the results.

  17. Transparent fast neutron shielding material and shielding method

    International Nuclear Information System (INIS)

    Nashimoto, Tetsuji; Katase, Haruhisa.

    1993-01-01

    Polyisobutylene having a viscosity average molecular weight of 20,000 to 80,000 and a hydrogen atom density of greater than 7.0 x 10 22 /cm 3 is used as a fast neutron shielding material. The shielding material is excellent in the shielding performance against fast neutrons, and there is no worry of leakage even when holes should be formed to a vessel. Further, it is excellent in fabricability, relatively safe even upon occurrence of fire and, in addition, it is transparent to enable to observe contents easily. (T.M.)

  18. Electromagnetically shielded building

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, T; Nakamura, M; Yabana, Y; Ishikawa, T; Nagata, K

    1992-04-21

    This invention relates to a building having an electromagnetic shield structure well-suited for application to an information network system utilizing electromagnetic waves, and more particularly to an electromagnetically shielded building for enhancing the electromagnetic shielding performance of an external wall. 6 figs.

  19. Electromagnetically shielded building

    International Nuclear Information System (INIS)

    Takahashi, T.; Nakamura, M.; Yabana, Y.; Ishikawa, T.; Nagata, K.

    1992-01-01

    This invention relates to a building having an electromagnetic shield structure well-suited for application to an information network system utilizing electromagnetic waves, and more particularly to an electromagnetically shielded building for enhancing the electromagnetic shielding performance of an external wall. 6 figs

  20. Radiation shielding concrete

    International Nuclear Information System (INIS)

    Kunishima, Shigeru.

    1990-01-01

    The radiation shielding concretes comprise water, cement, fine aggregates consisting of serpentines and blown mist slags, coarse aggregates consisting of serpentines and kneading materials. Since serpentines containing a relatively great amount of water of crystallization in rocks as coarse aggregates and fine aggregates, the hydrogen content in the radiation shielding concretes is increased and the neutron shielding effect is improved. In addition, since serpentines are added as the fine aggregates and blown mists slags of a great specific gravity are used, the specific gravity of the shielding concretes is increased to improve the γ-ray shielding effect. Further, by the use of the kneading material having a water reducing effect and fluidizing effect, and by the bearing effect of the spherical blown mist slags used as the fine aggregates, concrete fluidity can be increased. Accordingly, workability of the radiation shielding concretes can be improved. (T.M.)

  1. Shielding augmentation of roll-on shield from NAPS to Kaiga-2

    International Nuclear Information System (INIS)

    Pradhan, A.S.; Kumar, A.N.

    2000-01-01

    Extensive radiation field surveys were conducted in NAPS and KAPS reactor buildings as a part of commissioning checks on radiation shielding. During such surveys, dose rate higher than the expected values were noticed in fuelling machine service areas. A movable shield, separating high field area fuelling machine vault and low field area fuelling machine service area, known as roll-on shield was identified as one of the causes of high field in fuelling machine service area along with weaker end-shield. This paper discusses systematic approach adopted in bringing down the dose rates in fuelling machine service area by augmentation of roll-on shield. (author)

  2. Living Guianas Report 2012

    NARCIS (Netherlands)

    Verlinden, A.T.N.; Verweij, P.A.; Plouvier, D.; Gomes, L.

    2012-01-01

    The Guianas are the three countries Guyana, Suriname and French Guiana, in the north east corner of mainland South America. They are included in the larger Guiana Shield and the Amazon biome. As such they are part of the largest tract of continuous tropical forest in an almost pristine state in the

  3. Geological analysis of parts of the southern Arabian Shield based on Landsat imagery

    Science.gov (United States)

    Qari, Mohammed Yousef Hedaytullah T.

    This thesis examines the capability and applicability of Landsat multispectral remote sensing data for geological analysis in the arid southern Arabian Shield, which is the eastern segment of the Nubian-Arabian Shield surrounding the Red Sea. The major lithologies in the study area are Proterozoic metavolcanics, metasediments, gneisses and granites. Three test-sites within the study area, located within two tectonic assemblages, the Asir Terrane and the Nabitah Mobile Belt, were selected for detailed comparison of remote sensing methods and ground geological studies. Selected digital image processing techniques were applied to full-resolution Landsat TM imagery and the results are interpreted and discussed. Methods included: image contrast improvement, edge enhancement for detecting lineaments and spectral enhancement for geological mapping. The last method was based on two principles, statistical analysis of the data and the use of arithmetical operators. New and detailed lithological and structural maps were constructed and compared with previous maps of these sites. Examples of geological relations identified using TM imagery include: recognition and mapping of migmatites for the first time in the Arabian Shield; location of the contact between the Asir Terrane and the Nabitah Mobile Belt; and mapping of lithologies, some of which were not identified on previous geological maps. These and other geological features were confirmed by field checking. Methods of lineament enhancement implemented in this study revealed structural lineaments, mostly mapped for the first time, which can be related to regional tectonics. Structural analysis showed that the southern Arabian Shield has been affected by at least three successive phases of deformation. The third phase is the most dominant and widespread. A crustal evolutionary model in the vicinity of the study area is presented showing four stages, these are: arc stage, accretion stage, collision stage and post

  4. Comparison of some lead and non-lead based glass systems, standard shielding concretes and commercial window glasses in terms of shielding parameters in the energy region of 1 keV-100 GeV: A comparative study

    International Nuclear Information System (INIS)

    Kurudirek, Murat; Ozdemir, Yueksel; Simsek, Onder; Durak, Ridvan

    2010-01-01

    The effective atomic numbers, Z eff of some glass systems with and without Pb have been calculated in the energy region of 1 keV-100 GeV including the K absorption edges of high Z elements present in the glass. Also, these glass systems have been compared with some standard shielding concretes and commercial window glasses in terms of mean free paths and total mass attenuation coefficients in the continuous energy range. Comparisons with experiments were also provided wherever possible for glasses. It has been observed that the glass systems without Pb have higher values of Z eff than that of Pb based glasses at some high energy regions even if they have lower mean atomic numbers than Pb based glasses. When compared with some standard shielding concretes and commercial window glasses, generally it has been shown that the given glass systems have superior properties than concretes and window glasses with respect to the radiation-shielding properties, thus confirming the availability of using these glasses as substitutes for some shielding concretes and commercial window glasses to improve radiation-shielding properties in the continuous energy region.

  5. Shielding from cosmic radiation for interplanetary missions Active and passive methods

    CERN Document Server

    Spillantini, P; Durante, M; Müller-Mellin, R; Reitz, G; Rossi, L; Shurshakov, V; Sorbi, M

    2007-01-01

    Shielding is arguably the main countermeasure for the exposure to cosmic radiation during interplanetary exploratory missions. However, shielding of cosmic rays, both of galactic or solar origin, is problematic, because of the high energy of the charged particles involved and the nuclear fragmentation occurring in shielding materials. Although computer codes can predict the shield performance in space, there is a lack of biological and physical measurements to benchmark the codes. An attractive alternative to passive, bulk material shielding is the use of electromagnetic fields to deflect the charged particles from the spacecraft target. Active shielding concepts based on electrostatic fields, plasma, or magnetic fields have been proposed in the past years, and should be revised based on recent technological improvements. To address these issues, the European Space Agency (ESA) established a Topical Team (TT) in 2002 including European experts in the field of space radiation shielding and superconducting magn...

  6. Wake Shield Target Protection

    International Nuclear Information System (INIS)

    Valmianski, Emanuil I.; Petzoldt, Ronald W.; Alexander, Neil B.

    2003-01-01

    The heat flux from both gas convection and chamber radiation on a direct drive target must be limited to avoid target damage from excessive D-T temperature increase. One of the possibilities of protecting the target is a wake shield flying in front of the target. A shield will also reduce drag force on the target, thereby facilitating target tracking and position prediction. A Direct Simulation Monte Carlo (DSMC) code was used to calculate convection heat loads as boundary conditions input into ANSYS thermal calculations. These were used for studying the quality of target protection depending on various shapes of shields, target-shield distance, and protective properties of the shield moving relative to the target. The results show that the shield can reduce the convective heat flux by a factor of 2 to 5 depending on pressure, temperature, and velocity. The protective effect of a shield moving relative to the target is greater than the protective properties of a fixed shield. However, the protective effect of a shield moving under the drag force is not sufficient for bringing the heat load on the target down to the necessary limit. Some other ways of diminishing heat flux using a protective shield are discussed

  7. Detail AR2-PR1 geochronological scale of the Baltic Shield

    International Nuclear Information System (INIS)

    Balashov, Yu.A.

    1995-01-01

    The version of the detail scale of the Precambrian Baltic Shield, based on selection of new crust increment through mantel genesis material is presented. The AR 2 -PR 1 -scale of the Baltic Shield is based through U-Pb, Rb-Sr and Sm-Nd-methods for the Cord Peninsula on the Precambrian period of the other Baltic Shield regions

  8. Optimal beta-ray shielding thicknesses for different therapeutic radionuclides and shielding materials

    International Nuclear Information System (INIS)

    Cho, Yong In; Kim, Ja Mee; Kim, Jung Hoon

    2017-01-01

    To better understand the distribution of deposited energy of beta and gamma rays according to changes in shielding materials and thicknesses when radionuclides are used for therapeutic nuclear medicine, a simulation was conducted. The results showed that due to the physical characteristics of each therapeutic radionuclide, the thicknesses of shielding materials at which beta-ray shielding takes place varied. Additional analysis of the shielding of gamma ray was conducted for radionuclides that emit both beta and gamma rays simultaneously with results showing shielding effects proportional to the atomic number and density of the shielding materials. Also, analysis of bremsstrahlung emission after beta-ray interactions in the simulation revealed that the occurrence of bremsstrahlung was relatively lower than theoretically calculated and varied depending on different radionuclides. (authors)

  9. The shielding calculation for the CN guide shielding assembly in HANARO

    International Nuclear Information System (INIS)

    Kim, H. S.; Lee, B. C.; Lee, K. H.; Kim, H.

    2006-01-01

    The cold neutron research facility in HANARO is under construction. The area including neutron guides and rotary shutter in the reactor hall should be shielded by the guide shielding assembly which is constructed of heavy concrete blocks and structure. The guide shielding assembly is divided into 2 parts, A and B. Part A is about 6.4 meters apart from the reactor biological shield and it is constructed of heavy concrete blocks whose density is above 4.0g/cm 3 . And part B is a fixed heavy concrete structure whose density is above 3.5g/cm 3 . The rotary shutter is also made with heavy concrete whose density is above 4.0g/cm 3 and includes 5 neutron guides inside. It can block the neutron beam by rotating when CNS is not operating. The dose criterion outside the guide shielding assembly is established as 12.5 μSv/hr which is also applied to reactor shielding in HANARO

  10. Shielding synchrotron light sources: Advantages of circular shield walls tunnels

    Energy Technology Data Exchange (ETDEWEB)

    Kramer, S.L. [Design and Accelerator Operations Consulting, 568 Wintergreen Ct Ridge, NY 11961 (United States); Ghosh, V.J.; Breitfeller, M. [NSLS-II, Brookhaven National Laboratory, Upton, NY 11973 (United States)

    2016-08-11

    Third generation high brightness light sources are designed to have low emittance and high current beams, which contribute to higher beam loss rates that will be compensated by Top-Off injection. Shielding for these higher loss rates will be critical to protect the projected higher occupancy factors for the users. Top-Off injection requires a full energy injector, which will demand greater consideration of the potential abnormal beam miss-steering and localized losses that could occur. The high energy electron injection beam produce significantly higher neutron component dose to the experimental floor than lower energy injection and ramped operations. High energy neutrons produced in the forward direction from thin target beam losses are a major component of the dose rate outside the shield walls of the tunnel. The convention has been to provide thicker 90° ratchet walls to reduce this dose to the beam line users. We present an alternate circular shield wall design, which naturally and cost effectively increases the path length for this forward radiation in the shield wall and thereby substantially decreasing the dose rate for these beam losses. This shield wall design will greatly reduce the dose rate to the users working near the front end optical components but will challenge the beam line designers to effectively utilize the longer length of beam line penetration in the shield wall. Additional advantages of the circular shield wall tunnel are that it's simpler to construct, allows greater access to the insertion devices and the upstream in tunnel beam line components, as well as reducing the volume of concrete and therefore the cost of the shield wall.

  11. INTOR radiation shielding for personnel access

    International Nuclear Information System (INIS)

    Gohar, Y.; Abdou, M.

    1981-01-01

    The INTOR reactor shield system consists of the blanket, bulk shield, penetration shield, component shield, and biological shield. The bulk shield consists of two parts: (a) the inboard shield; and (b) the outboard shield. The distinction between the different components of the shield system is essential to satisfy the different design constraints and achieve various objectives

  12. HIV and syphilis infection among gold and diamond miners--Guyana, 2004.

    Science.gov (United States)

    Seguy, N; Denniston, M; Hladik, W; Edwards, M; Lafleur, C; Singh-Anthony, S; Diaz, T

    2008-11-01

    Guyana had an estimated HIVprevalence of 1.5% among pregnant women in 2006 (95% confidence interval [CI] = 1.1-1.9). However, a survey of miners in one mine found a 6.5% HIV prevalence in 2002. To determine whether Guyanese miners are at high risk for HIV infection we conducted a HIV and syphilis prevalence survey of miners in several mines. Adult male consenting miners in 45 Guyanese mines were interviewed, counselled, tested for HIV and syphilis with rapid tests and provided onsite test results. The survey was cross-sectional and used a multi-stage cluster sampling design; population estimates were calculated using SUDAAN. Of 651 miners approached, 539 (83%) were interviewed and 509 (78%) tested. The estimated prevalence for HIV was 3.9% (CI = 2.1, 7.1) and for life-time syphilis exposure was 6.4% (CI = 4.5, 9.1). Fifty-four per cent (CI = 41.3, 66.7) of miners had casual sex during the preceding year, of whom 44.4% (CI = 34.3, 55.0) had always used condoms with these partners. The estimated HIV prevalence among Guyanese miners was higher than that of the general population. Targeted interventions including condom promotion are recommended to prevent further spread of HIV and other sexually transmitted infections among miners.

  13. Acoustic Metacages for Omnidirectional Sound Shielding

    OpenAIRE

    Shen, Chen; Xie, Yangbo; Li, Junfei; Cummer, Steven A.; Jing, Yun

    2017-01-01

    Conventional sound shielding structures typically prevent fluid transport between the exterior and interior. A design of a two-dimensional acoustic metacage with subwavelength thickness which can shield acoustic waves from all directions while allowing steady fluid flow is presented in this paper. The structure is designed based on acoustic gradient-index metasurfaces composed of open channels and shunted Helmholtz resonators. The strong parallel momentum on the metacage surface rejects in-pl...

  14. Radiation shielding of the main injector

    International Nuclear Information System (INIS)

    Bhat, C.M.; Martin, P.S.

    1995-05-01

    The radiation shielding in the Fermilab Main Injector (FMI) complex has been carried out by adopting a number of prescribed stringent guidelines established by a previous safety analysis. Determination of the required amount of radiation shielding at various locations of the FMI has been done using Monte Carlo computations. A three dimensional ray tracing code as well as a code based upon empirical observations have been employed in certain cases

  15. Amended diagnosis and redescription of Pristimantis marmoratus (Boulenger, 1900 (Amphibia: Craugastoridae, with a description of its advertisement call and notes on its breeding ecology and phylogenetic relationships

    Directory of Open Access Journals (Sweden)

    Philippe J.R. Kok

    2018-01-01

    Full Text Available The frog Pristimantis marmoratus was originally described as Hylodes marmoratus by George A. Boulenger in 1900 based on a single specimen reported to have been collected at the foot of Mount Roraima in Guyana in 1898. We herein discuss the exact location of the type locality of P. marmoratus and provide a redescription of the species based on new material from Kaieteur National Park and from the slopes of Maringma-tepui in Guyana. We also describe the previously unknown vocalization and breeding ecology of the species, and conducted an exploratory molecular analysis of the phylogenetic relationships within the genus Pristimantis represented by the members of the “unistrigatus species group” in the Guiana Shield. Pristimantis marmoratus is a small-sized species mainly distinguished from its known Guiana Shield congeners by the combination of F I < II, SVL ≤ 20.4 in males, presence of vocal slits in males, granular/pustulate dorsal skin with well-developed scapular ridges, basal webbing between fingers, fringes on fingers and toes, crossed iris, diffuse yellow or pale green wash on groin, and absence of flashy colour on axillary/pre-axillary region. The advertisement call consists of a single note repeated at a rate of ca 11 calls/min with a dominant frequency ranging from 2756 to 3101 Hz. Pristimantis marmoratus is primarily arboreal, exclusively active at dusk, and probably restricted to the pristine rainforests of the Pantepui uplands and highlands, east of the Gran Sabana between ca 600 and 1800 m above sea level. Preliminary molecular analyses recovered Pristimantis marmoratus as sister to an unnamed species from the Eastern Guiana Shield. On grounds of the newly established distributional extent we suggest maintaining the IUCN conservation status as Least Concern.

  16. Introduction of spirometry into clinical practice in Georgetown, Guyana: quality and diagnostic outcomes.

    Science.gov (United States)

    Johnston, J C; Rempel, C; Sanders, C; Piggott, E; Maxwell, Y; Jaipersaud, K; Luknauth, R; Persaud, D; Rambaran, M; Levy, R D

    2016-09-01

    Georgetown Public Hospital Corporation (GPHC), a 600-bed publicly funded referral hospital in Georgetown, Guyana. To assess spirometry quality and diagnostic outcomes 2 years after the introduction of spirometry into routine clinical practice at GPHC. We performed a retrospective review of 476 consecutive spirometry assessments performed from November 2013 to November 2015. We assessed the proportion and trend of spirometry tests meeting acceptability criteria, along with diagnostic interpretations and spirometry laboratory referral patterns. Overall, 80.4% of the 454 initial spirometry measurements on unique patients met the acceptability criteria, with no significant change in the proportion of acceptable spirometry over the study period (P = 0.450). Of the 369 (81.3%) first tests considered interpretable, 139 (30.6%) were normal, 151 (33.3%) were obstructive, 54 (11.9%) were suggestive of a restrictive pattern, 25 (5.5%) were suggestive of a mixed disorder and 119 (26.2%) tests met the definition of reversibility. Over a 2-year period, high-quality spirometry was performed in GPHC, a publicly funded hospital in a middle-income country with no pre-existing specialised respiratory service.

  17. Space nuclear reactor shields for manned and unmanned applications

    International Nuclear Information System (INIS)

    McKissock, B.I.; Bloomfield, H.S.

    1990-01-01

    Missions which use nuclear reactor power systems require radiation shielding of payload and/or crew areas to predetermined dose rates. Since shielding can become a significant fraction of the total mass of the system, it is of interest to show the effect of various parameters on shield thickness and mass for manned and unmanned applications. Algorithms were developed to give the thicknesses needed if reactor thermal power, separation distances and dose rates are given as input. The thickness algorithms were combined with models for four different shield geometries to allow tradeoff studies of shield volume and mass for a variety of manned and unmanned missions. The shield design tradeoffs presented in this study include the effects of: higher allowable dose rates; radiation hardened electronics; shorter crew exposure times; shield geometry; distance of the payload and/or crew from the reactor; and changes in the size of the shielded area. Specific NASA missions that were considered in this study include unmanned outer planetary exploration, manned advanced/evolutionary space station and advanced manned lunar base. (author)

  18. Space nuclear reactor shields for manned and unmanned applications

    International Nuclear Information System (INIS)

    Mckissock, B.I.; Bloomfield, H.S.

    1989-01-01

    Missions which use nuclear reactor power systems require radiation shielding of payload and/or crew areas to predetermined dose rates. Since shielding can become a significant fraction of the total mass of the system, it is of interest to show the effect of various parameters on shield thickness and mass for manned and unmanned applications. Algorithms were developed to give the thicknesses needed if reactor thermal power, separation distances, and dose rates are given as input. The thickness algorithms were combined with models for four different shield geometries to allow tradeoff studies of shield volume and mass for a variety of manned and unmanned missions. Shield design tradeoffs presented in this study include the effects of: higher allowable dose rates; radiation hardened electronics; shorter crew exposure times; shield geometry; distance of the payload and/or crew from the reactor; and changes in the size of the shielded area. Specific NASA missions that were considered in this study include unmanned outer planetary exploration, manned advanced/evolutionary space station, and advanced manned lunar base

  19. Graphical-based construction of combinatorial geometries for radiation transport and shielding applications

    International Nuclear Information System (INIS)

    Burns, T.J.

    1992-01-01

    A graphical-based code system is being developed at ORNL to manipulate combinatorial geometries for radiation transport and shielding applications. The current version (basically a combinatorial geometry debugger) consists of two parts: a FORTRAN-based ''view'' generator and a Microsoft Windows application for displaying the geometry. Options and features of both modules are discussed. Examples illustrating the various options available are presented. The potential for utilizing the images produced using the debugger as a visualization tool for the output of the radiation transport codes is discussed as is the future direction of the development

  20. Investigation on Shielding Failure of a Novel 400 kV Composite tower

    DEFF Research Database (Denmark)

    Wang, Qian; Jahangiri, Tohid; Bak, Claus Leth

    2018-01-01

    In this paper, the lightning shielding performance of a newly-designed 400 kV double-circuit composite tower is investigated. Based on a revised EGM method, traditional shielding failure regions, located at both sides of a traditional tower is no longer a big issue for the fully composite tower......, due to its unusual ‘Y’ configuration. Instead, a new unprotected region exists in the tower center. The maximum lightning current that can lead to shielding failure and the shielding failure rate (SFR) of the new tower are calculated. To verify results from the revised EGM method, a scale model test...... is conducted. Spatial shielding failure probability around the tower is calculated based on ratio of discharge paths recorded in the test. Moreover, based on test results, the maximum shielding failure lightning currents are obtained. Analysis and results derived from the revised EGM method and scale model...

  1. Infinite slab-shield dose calculations

    International Nuclear Information System (INIS)

    Russell, G.J.

    1989-01-01

    I calculated neutron and gamma-ray equivalent doses leaking through a variety of infinite (laminate) slab-shields. In the shield computations, I used, as the incident neutron spectrum, the leakage spectrum (<20 MeV) calculated for the LANSCE tungsten production target at 90 degree to the target axis. The shield thickness was fixed at 60 cm. The results of the shield calculations show a minimum in the total leakage equivalent dose if the shield is 40-45 cm of iron followed by 20-15 cm of borated (5% B) polyethylene. High-performance shields can be attained by using multiple laminations. The calculated dose at the shield surface is very dependent on shield material. 4 refs., 4 figs., 1 tab

  2. Uncertainty Analysis with Considering Resonance Self-shielding Effect

    Energy Technology Data Exchange (ETDEWEB)

    Han, Tae Young [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    If infinitely diluted multi-group cross sections were used for the sensitivity, the covariance data from the evaluated nuclear data library (ENDL) was directly applied. However, in case of using a self-shielded multi-group cross section, the covariance data should be corrected considering self-shielding effect. Usually, implicit uncertainty can be defined as the uncertainty change by the resonance self-shielding effect as described above. MUSAD ( Modules of Uncertainty and Sensitivity Analysis for DeCART ) has been developed for a multiplication factor and cross section uncertainty based on the generalized perturbation theory and it, however, can only quantify the explicit uncertainty by the self-shielded multi-group cross sections without considering the implicit effect. Thus, this paper addresses the implementation of the implicit uncertainty analysis module into the code and the numerical results for the verification are provided. The implicit uncertainty analysis module has been implemented into MUSAD based on infinitely-diluted cross section-based consistent method. The verification calculation was performed on MHTGR 350 Ex.I-1a and the differences with McCARD result decrease from 40% to 1% in CZP case and 3% in HFP case. From this study, it is expected that MUSAD code can reasonably produce the complete uncertainty on VHTR or LWR where the resonance self-shielding effect should be significantly considered.

  3. Uncertainty Analysis with Considering Resonance Self-shielding Effect

    International Nuclear Information System (INIS)

    Han, Tae Young

    2016-01-01

    If infinitely diluted multi-group cross sections were used for the sensitivity, the covariance data from the evaluated nuclear data library (ENDL) was directly applied. However, in case of using a self-shielded multi-group cross section, the covariance data should be corrected considering self-shielding effect. Usually, implicit uncertainty can be defined as the uncertainty change by the resonance self-shielding effect as described above. MUSAD ( Modules of Uncertainty and Sensitivity Analysis for DeCART ) has been developed for a multiplication factor and cross section uncertainty based on the generalized perturbation theory and it, however, can only quantify the explicit uncertainty by the self-shielded multi-group cross sections without considering the implicit effect. Thus, this paper addresses the implementation of the implicit uncertainty analysis module into the code and the numerical results for the verification are provided. The implicit uncertainty analysis module has been implemented into MUSAD based on infinitely-diluted cross section-based consistent method. The verification calculation was performed on MHTGR 350 Ex.I-1a and the differences with McCARD result decrease from 40% to 1% in CZP case and 3% in HFP case. From this study, it is expected that MUSAD code can reasonably produce the complete uncertainty on VHTR or LWR where the resonance self-shielding effect should be significantly considered

  4. Electromagnetic shield

    International Nuclear Information System (INIS)

    Miller, J.S.

    1987-01-01

    An electromagnetic shield is described comprising: closed, electrically-conductive rings, each having an open center; and binder means for arranging the rings in a predetermined, fixed relationship relative to each other, the so-arranged rings and binder means defining an outer surface; wherein electromagnetic energy received by the shield from a source adjacent its outer surface induces an electrical current to flow in a predetermined direction adjacent and parallel to the outer surface, through the rings; and wherein each ring is configured to cause source-induced alternating current flowing through the portion of the ring closest to the outer surface to electromagnetically induce an oppositely-directed current in the portion of the ring furthest from the surface, such oppositely-directed current bucking any source-induced current in the latter ring portion and thus reducing the magnitude of current flowing through it, whereby the electromagnetic shielding effected by the shield is enhanced

  5. Modelling and Optimization of Four-Segment Shielding Coils of Current Transformers.

    Science.gov (United States)

    Gao, Yucheng; Zhao, Wei; Wang, Qing; Qu, Kaifeng; Li, He; Shao, Haiming; Huang, Songling

    2017-05-26

    Applying shielding coils is a practical way to protect current transformers (CTs) for large-capacity generators from the intensive magnetic interference produced by adjacent bus-bars. The aim of this study is to build a simple analytical model for the shielding coils, from which the optimization of the shielding coils can be calculated effectively. Based on an existing stray flux model, a new analytical model for the leakage flux of partial coils is presented, and finite element method-based simulations are carried out to develop empirical equations for the core-pickup factors of the models. Using the flux models, a model of the common four-segment shielding coils is derived. Furthermore, a theoretical analysis is carried out on the optimal performance of the four-segment shielding coils in a typical six-bus-bars scenario. It turns out that the "all parallel" shielding coils with a 45° starting position have the best shielding performance, whereas the "separated loop" shielding coils with a 0° starting position feature the lowest heating value. Physical experiments were performed, which verified all the models and the conclusions proposed in the paper. In addition, for shielding coils with other than the four-segment configuration, the analysis process will generally be the same.

  6. Methane emission and oxygen consumption in the hydroelectric dam of Petit Saut in French Guyana

    International Nuclear Information System (INIS)

    Galy-Lacaux, C.; Jambert, C.; Delmas, R.; Dumestre, J.F.; Labroue, L.; Cerdan, P.; Richard, S.

    1996-01-01

    Methane emissions from the hydroelectric dam of Petit-Saut, in French Guyana, were measured over a 20-months period. Since the beginning of the reservoir filling (January 1994), 300 km 2 of tropical forest have been submerged. Biological CH 4 oxidation, in the surface water of the lake and in the river downstream of the dam, lead to an intense 0 2 consumption. Emissions of CH 4 by diffusion into the atmosphere or by degassing of the water released into the river as well as the stock of dissolved gas in the lake, and their temporal dynamics, were studied. Maximum emissions of 700 t (CH 4 ) per day were attained in February 1994, corresponding to maximum dissolved CH 4 concentrations of 14 mg l -1 in the water column. Total emissions since January 1994, were calculated from the whole data set. (authors). 7 refs., 2 figs., 1 tab

  7. Space Shielding Materials for Prometheus Application

    Energy Technology Data Exchange (ETDEWEB)

    R. Lewis

    2006-01-20

    At the time of Prometheus program restructuring, shield material and design screening efforts had progressed to the point where a down-selection from approximately eighty-eight materials to a set of five ''primary'' materials was in process. The primary materials were beryllium (Be), boron carbide (B{sub 4}C), tungsten (W), lithium hydride (LiH), and water (H{sub 2}O). The primary materials were judged to be sufficient to design a Prometheus shield--excluding structural and insulating materials, that had not been studied in detail. The foremost preconceptual shield concepts included: (1) a Be/B{sub 4}C/W/LiH shield; (2) a Be/B{sub 4}C/W shield; (3) and a Be/B{sub 4}C/H{sub 2}O shield. Since the shield design and materials studies were still preliminary, alternative materials (e.g., {sup nal}B or {sup 10}B metal) were still being screened, but at a low level of effort. Two competing low mass neutron shielding materials are included in the primary materials due to significant materials uncertainties in both. For LiH, irradiation-induced swelling was the key issue, whereas for H{sub 2}O, containment corrosion without active chemistry control was key, Although detailed design studies are required to accurately estimate the mass of shields based on either hydrogenous material, both are expected to be similar in mass, and lower mass than virtually any alternative. Unlike Be, W, and B{sub 4}C, which are not expected to have restrictive temperature limits, shield temperature limits and design accommodations are likely to be needed for either LiH or H{sub 2}O. The NRPCT focused efforts on understanding swelting of LiH, and observed, from approximately fifty prior irradiation tests, that either casting ar thorough out-gassing should reduce swelling. A potential contributor to LiH swelling appears to be LiOH contamination due to exposure to humid air, that can be eliminated by careful processing. To better understand LiH irradiation performance and

  8. The Active Muon Shield

    CERN Document Server

    Bezshyiko, Iaroslava

    2016-01-01

    In the SHiP beam-dump of the order of 1011 muons will be produced per second. An active muon-shield is used to magnetically deflect these muons out of the acceptance of the spectrom- eter. This note describes how this shield is modelled and optimized. The SHiP spectrometer is being re-optimized using a conical decay-vessel, and utilizing the possibility to magnetize part of the beam-dump shielding iron. A shield adapted to these new conditions is presented which is significantly shorter and lighter than the shield used in the Technical Proposal (TP), while showing a similar performance.

  9. Shielding analysis method applied to nuclear ship 'MUTSU' and its evaluation based on experimental analyses

    International Nuclear Information System (INIS)

    Yamaji, Akio; Miyakoshi, Jun-ichi; Iwao, Yoshiaki; Tsubosaka, Akira; Saito, Tetsuo; Fujii, Takayoshi; Okumura, Yoshihiro; Suzuoki, Zenro; Kawakita, Takashi.

    1984-01-01

    Procedures of shielding analysis are described which were used for the shielding modification design of the Nuclear Ship ''MUTSU''. The calculations of the radiation distribution on board were made using Sn codes ANISN and TWOTRAN, a point kernel code QAD and a Monte Carlo code MORSE. The accuracies of these calculations were investigated through the analysis of various shielding experiments: the shield tank experiment of the Nuclear Ship ''Otto Hahn'', the shielding mock-up experiment for ''MUTSU'' performed in JRR-4, the shielding benchmark experiment using the 16 N radiation facility of AERE Harwell and the shielding effect experiment of the ship structure performed in the training ship ''Shintoku-Maru''. The values calculated by the ANISN agree with the data measured at ''Otto Hahn'' within a factor of 2 for fast neutrons and within a factor of 3 for epithermal and thermal neutrons. The γ-ray dose rates calculated by the QAD agree with the measured values within 30% for the analysis of the experiment in JRR-4. The design values for ''MUTSU'' were determined in consequence of these experimental analyses. (author)

  10. Commissioning of a grid-based Boltzmann solver for cervical cancer brachytherapy treatment planning with shielded colpostats.

    Science.gov (United States)

    Mikell, Justin K; Klopp, Ann H; Price, Michael; Mourtada, Firas

    2013-01-01

    We sought to commission a gynecologic shielded colpostat analytic model provided from a treatment planning system (TPS) library. We have reported retrospectively the dosimetric impact of this applicator model in a cohort of patients. A commercial TPS with a grid-based Boltzmann solver (GBBS) was commissioned for (192)Ir high-dose-rate (HDR) brachytherapy for cervical cancer with stainless steel-shielded colpostats. Verification of the colpostat analytic model was verified using a radiograph and vendor schematics. MCNPX v2.6 Monte Carlo simulations were performed to compare dose distributions around the applicator in water with the TPS GBBS dose predictions. Retrospectively, the dosimetric impact was assessed over 24 cervical cancer patients' HDR plans. Applicator (TPS ID #AL13122005) shield dimensions were within 0.4 mm of the independent shield dimensions verification. GBBS profiles in planes bisecting the cap around the applicator agreed with Monte Carlo simulations within 2% at most locations; differing screw representations resulted in differences of up to 9%. For the retrospective study, the GBBS doses differed from TG-43 as follows (mean value ± standard deviation [min, max]): International Commission on Radiation units [ICRU]rectum (-8.4 ± 2.5% [-14.1, -4.1%]), ICRUbladder (-7.2 ± 3.6% [-15.7, -2.1%]), D2cc-rectum (-6.2 ± 2.6% [-11.9, -0.8%]), D2cc-sigmoid (-5.6 ± 2.6% [-9.3, -2.0%]), and D2cc-bladder (-3.4 ± 1.9% [-7.2, -1.1%]). As brachytherapy TPSs implement advanced model-based dose calculations, the analytic applicator models stored in TPSs should be independently validated before clinical use. For this cohort, clinically meaningful differences (>5%) from TG-43 were observed. Accurate dosimetric modeling of shielded applicators may help to refine organ toxicity studies. Copyright © 2013 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  11. REACTOR SHIELD

    Science.gov (United States)

    Wigner, E.P.; Ohlinger, L.E.; Young, G.J.; Weinberg, A.M.

    1959-02-17

    Radiation shield construction is described for a nuclear reactor. The shield is comprised of a plurality of steel plates arranged in parallel spaced relationship within a peripheral shell. Reactor coolant inlet tubes extend at right angles through the plates and baffles are arranged between the plates at right angles thereto and extend between the tubes to create a series of zigzag channels between the plates for the circulation of coolant fluid through the shield. The shield may be divided into two main sections; an inner section adjacent the reactor container and an outer section spaced therefrom. Coolant through the first section may be circulated at a faster rate than coolant circulated through the outer section since the area closest to the reactor container is at a higher temperature and is more radioactive. The two sections may have separate cooling systems to prevent the coolant in the outer section from mixing with the more contaminated coolant in the inner section.

  12. Design of emergency shield

    International Nuclear Information System (INIS)

    Soliman, S.E.

    1993-01-01

    Manufacturing of an emergency movable shield in the hot laboratories center is urgently needed for the safety of personnel in case of accidents or spilling of radioactive materials. In this report, a full design for an emergency shield is presented and the corresponding dose rates behind the shield for different activities (from 1 mCi to 5 Ci) was calculated by using micro shield computer code. 4 figs., 1 tab

  13. Micronutrient deficiencies in the English-speaking Caribbean and in Guyana

    Directory of Open Access Journals (Sweden)

    1998-01-01

    Full Text Available Tres estudios recientes analizaron el grado de deficiencia de vitamina A, betacarotenos y hierro en Jamaica, Antigua y Barbuda, Dominica, San Vicente y las Granadinas y Guyana. Todos los estudios fueron efectuados por el Instituto Caribeño de Alimentación y Nutrición, o en colaboración con él. En todas las encuestas, que fueron similares en su estructura y resultados, se recolectaron muestras de sangre con el fin de determinar las deficiencias de micronutrientes. También se aplicaron cuestionarios para recoger información sobre los patrones de alimentación. Los principales grupos estudiados fueron los niños pequeños, los escolares y las mujeres embarazadas. La anemia por deficiencia de hierro fue la deficiencia de micronutrientes más común de las que se encontraron en los tres estudios. Aunque se hallaron pocos casos de deficiencia de vitamina A grave, fueron más comunes las deficiencias marginales. En los tres estudios se hicieron recomendaciones similares para hacer frente a las deficiencias detectadas en los diversos países. Es menester que los gobiernos y otras agencias sigan promoviendo la disponibilidad y el consumo de alimentos ricos en vitamina A y caroteno. Los programas contra la anemia deben dirigirse específicamente hacia los niños de 1 a 4 años de edad y las mujeres embarazadas.

  14. Analytic flux formulas and tables of shielding functions

    International Nuclear Information System (INIS)

    Wallace, O.J.

    1981-06-01

    Hand calculations of radiation flux and dose rates are often useful in evaluating radiation shielding and in determining the scope of a problem. The flux formulas appropriate to such calculations are almost always based on the point kernel and allow for at most the consideration of laminar slab shields. These formulas often require access to tables of values of integral functions for effective use. Flux formulas and function tables appropriate to calculations involving homogeneous source regions with the shapes of lines, disks, slabs, truncated cones, cylinders, and spheres are presented. Slab shields may be included in most of these calculations, and the effect of a cylindrical shield surrounding a cylindrical source may be estimated. Detector points may be located axially, laterally, or interior to a cylindrical source. Line sources may be tilted with respect to a slab shield. All function tables are given for a wide range of arguments

  15. Primary shield displacement and bowing

    International Nuclear Information System (INIS)

    Scott, K.V.

    1978-01-01

    The reactor primary shield is constructed of high density concrete and surrounds the reactor core. The inlet, outlet and side primary shields were constructed in-place using 2.54 cm (1 in) thick steel plates as the forms. The plates remained as an integral part of the shields. The elongation of the pressure tubes due to thermal expansion and pressurization is not moving through the inlet nozzle hardware as designed but is accommodated by outward displacement and bowing of the inlet and outlet shields. Excessive distortion of the shields may result in gas seal failures, intolerable helium gas leaks, increased argon-41 emissions, and shield cooling tube failures. The shield surveillance and testing results are presented

  16. Evaluation of the shielding integrity of end-shields in PHWR type NPPs

    International Nuclear Information System (INIS)

    Sah, B.M.L.; Ramamirtham, B.; Kutty, B.S.

    1996-01-01

    In the new plants (Narora Atomic Power Plants (NAPP) onwards) relatively higher radiation fields exist on the north and south fuelling machine (FM) vault walls of the E1 100m accessible area passages. These fields were first noticed at NAPS-1 and subsequently at NAPS-2 and KAPS-1. Such surveys done at RAPS have indicated that the fields on these walls would come out to be quite low (only 1-2 mR/h) from sources other than that arising from 41 Ar contamination. RAPS/MAPS experience pointed to adequacy of shielding of the FM vault walls and sufficient overall shielding thickness of the end-shields. Further, radiometry tests of end-shields carried out at Kaiga and RAPP 3 and 4 indicated fairly satisfactory and uniform filling of balls. Hence, incomplete filling of water column of the end-shields due to any venting problem was suspected to be one possible reason for the observed high fields in NAPS and Kakrapar Atomic Power Station (KAPS). Since the presence of high radiation fields, both neutron and gamma, is of long-term concern, a special study/measurement of radiation levels on reactor face during high power operation was undertaken. In order to compare the shielding integrity of the older (RAPS/MAPS solid plate type shielding) and newer (NAPS/KAPS steel ball-filled type) end shields, these experiments were done at MAPS-2 and NAPS-2. (author). 2 refs., 2 tabs

  17. Magnetic shielding for superconducting RF cavities

    Science.gov (United States)

    Masuzawa, M.; Terashima, A.; Tsuchiya, K.; Ueki, R.

    2017-03-01

    Magnetic shielding is a key technology for superconducting radio frequency (RF) cavities. There are basically two approaches for shielding: (1) surround the cavity of interest with high permeability material and divert magnetic flux around it (passive shielding); and (2) create a magnetic field using coils that cancels the ambient magnetic field in the area of interest (active shielding). The choice of approach depends on the magnitude of the ambient magnetic field, residual magnetic field tolerance, shape of the magnetic shield, usage, cost, etc. However, passive shielding is more commonly used for superconducting RF cavities. The issue with passive shielding is that as the volume to be shielded increases, the size of the shielding material increases, thereby leading to cost increase. A recent trend is to place a magnetic shield in a cryogenic environment inside a cryostat, very close to the cavities, reducing the size and volume of the magnetic shield. In this case, the shielding effectiveness at cryogenic temperatures becomes important. We measured the permeabilities of various shielding materials at both room temperature and cryogenic temperature (4 K) and studied shielding degradation at that cryogenic temperature.

  18. Thermal testing of solid neutron shielding materials

    International Nuclear Information System (INIS)

    Boonstra, R.H.

    1992-09-01

    Two legal-weight truck casks the GA-4 and GA-9, will carry four PWR and nine BWR spent fuel assemblies, respectively. Each cask has a solid neutron shielding material separating the steel body and the outer steel skin. In the thermal accident specified by NRC regulations in 10CFR Part 71, the cask is subjected to an 800 degree C environment for 30 minutes. The neutron shield need not perform any shielding function during or after the thermal accident, but its behavior must not compromise the ability of the cask to contain the radioactive contents. In May-June 1989 the first series of full-scale thermal tests was performed on three shielding materials: Bisco Products NS-4-FR, and Reactor Experiments RX-201 and RX-207. The tests are described in Thermal Testing of Solid Neutron Shielding Materials, GA-AL 9897, R. H. Boonstra, General Atomics (1990), and demonstrated the acceptability of these materials in a thermal accident. Subsequent design changes to the cask rendered these materials unattractive in terms of weight or adequate service temperature margin. For the second test series, a material specification was developed for a polypropylene based neutron shield with a softening point of at least 280 degree F. The neutron shield materials tested were boronated (0.8--4.5%) polymers (polypropylene, HDPE, NS-4). The Envirotech and Bisco materials are not polypropylene, but were tested as potential backup materials in the event that a satisfactory polypropylene could not be found

  19. Development of silicone rubber-type neutron shielding material

    International Nuclear Information System (INIS)

    Do, Jae Bum; Cho, Soo Hang; Kim, Ik Soo; Oh, Seung Chul; Hong, Soon Seok; Noh, Sung Ki; Jeong, Duk Yeon.

    1997-06-01

    Because the exposure to radiation in the nuclear facilities can be fatal to human, it is important to reduce the radiation dose level to a tolerable level. The purpose of this study is to develop highly effective neutron shielding materials for the shipping and storage cask of radioactive materials or in the nuclear/radiation facilities. On this study, we developed silicone rubber based neutron shielding materials and their various material properties, including neutron shielding ability, fire resistance, combustion characteristics, radiation resistance, thermal and mechanical properties were evaluated experimentally. (author). 16 tabs., 17 figs., 25 refs

  20. Shielding container for radioactive isotopes

    International Nuclear Information System (INIS)

    Sumi, Tetsuo; Tosa, Masayoshi; Hatogai, Tatsuaki.

    1975-01-01

    Object: To effect opening and closing bidirectional radiation used particularly for a gamma densimeter or the like by one operation. Structure: This device comprises a rotatable shielding body for receiving radioactive isotope in the central portion thereof and having at least two radiation openings through which radiation is taken out of the isotope, and a shielding container having openings corresponding to the first mentioned radiation openings, respectively. The radioactive isotope is secured to a rotational shaft of the shielding body, and the shielding body is rotated to register the openings of the shielding container with the openings of the shielding body or to shield the openings, thereby effecting radiation and cut off of gamma ray in the bidirection by one operation. (Kamimura, M.)

  1. Calculations of atomic magnetic nuclear shielding constants based on the two-component normalized elimination of the small component method

    Science.gov (United States)

    Yoshizawa, Terutaka; Zou, Wenli; Cremer, Dieter

    2017-04-01

    A new method for calculating nuclear magnetic resonance shielding constants of relativistic atoms based on the two-component (2c), spin-orbit coupling including Dirac-exact NESC (Normalized Elimination of the Small Component) approach is developed where each term of the diamagnetic and paramagnetic contribution to the isotropic shielding constant σi s o is expressed in terms of analytical energy derivatives with regard to the magnetic field B and the nuclear magnetic moment 𝝁 . The picture change caused by renormalization of the wave function is correctly described. 2c-NESC/HF (Hartree-Fock) results for the σiso values of 13 atoms with a closed shell ground state reveal a deviation from 4c-DHF (Dirac-HF) values by 0.01%-0.76%. Since the 2-electron part is effectively calculated using a modified screened nuclear shielding approach, the calculation is efficient and based on a series of matrix manipulations scaling with (2M)3 (M: number of basis functions).

  2. Development of a shield based on Monte-Carlo studies for the COBRA experiment

    Energy Technology Data Exchange (ETDEWEB)

    Heidrich, Nadine [Institut fuer Experimentalphysik, 22761 Hamburg (Germany); Collaboration: COBRA-Collaboration

    2013-07-01

    COBRA is a next-generation experiment searching for neutrinoless double beta decay using CdZnTe semiconductor detectors. The main focus is on {sup 116}Cd, with a decay energy of 2813.5 keV well above the highest naturally occurring gamma lines. The concept for a large scale set-up consists of an array of CdZnTe detectors with a total mass of 420 kg enriched in {sup 116}Cd up to 90 %. With a background rate in the order of 10{sup -3} counts/keV/kg/year, the experiment would be sensitive to a half-life larger than 10{sup 26} years, corresponding to a Majorana mass term m{sub ββ} smaller than 50 meV. To achieve the background level, an appropriate shield is necessary. The shield is developed based on Monte-Carlo simulations. For that, different materials and configurations are tested. In the talk the current status of the Monte-Carlo survey is presented and discussed.

  3. Where have the neutrons gone: A history of the Tower Shielding Facility

    International Nuclear Information System (INIS)

    Muckenthaler, F.J.

    1992-01-01

    In the early 1950's, the concept of the unit shield for the nuclear powered aircraft reactor changed to one of the divided shield concept where the reactor and crew compartment shared the shielding load. Design calculations for the divided shield were being made based on data obtained in studies for the, unit shield. It was believed that these divided shield designs were subject to error, the magnitude of which could not be estimated. This belief led to the design of the Tower Shielding Facility where divided-shield-type measurements could be made without interference from ground or structural scattering. This paper discusses that facility, its reactors, and some chosen experiments from the list of many that were performed at that facility during the past 38 years

  4. Shielding in experimental areas

    International Nuclear Information System (INIS)

    Stevens, A.; Tarnopolsky, G.; Thorndike, A.; White, S.

    1979-01-01

    The amount of shielding necessary to protect experimental detectors from various sources of background radiation is discussed. As illustrated an experiment has line of sight to sources extending approx. 90 m upstream from the intersection point. Packing a significant fraction of this space with shielding blocks would in general be unacceptable because primary access to the ring tunnel is from the experimental halls. (1) From basic machine design considerations and the inherent necessity to protect superconducting magnets it is expected that experimental areas in general will be cleaner than at any existing accelerator. (2) Even so, it will likely be necessary to have some shielding blocks available to protect experimental apparatus, and it may well be necessary to have a large amount of shielding available in the WAH. (3) Scraping will likely have some influence on all halls, and retractable apparatus may sometimes be necessary. (4) If access to any tunnel is needed to replace a magnet, one has 96 h (4 days) available to move shielding away to permit access without additional downtime. This (the amount of shielding one can shuffle about in 96 h) is a reasonable upper limit to shielding necessary in a hall

  5. Radiation production and absorption in human spacecraft shielding systems under high charge and energy Galactic Cosmic Rays: Material medium, shielding depth, and byproduct aspects

    Science.gov (United States)

    Barthel, Joseph; Sarigul-Klijn, Nesrin

    2018-03-01

    Deep space missions such as the planned 2025 mission to asteroids require spacecraft shields to protect electronics and humans from adverse effects caused by the space radiation environment, primarily Galactic Cosmic Rays. This paper first reviews the theory on how these rays of charged particles interact with matter, and then presents a simulation for a 500 day Mars flyby mission using a deterministic based computer code. High density polyethylene and aluminum shielding materials at a solar minimum are considered. Plots of effective dose with varying shield depth, charged particle flux, and dose in silicon and human tissue behind shielding are presented.

  6. Development of highly effective neutron shields and neutron absorbing materials

    International Nuclear Information System (INIS)

    Tsuda, K.; Matsuda, F.; Taniuchi, H.; Yuhara, T.; Iida, T.

    1993-01-01

    A wide range of materials, including polymers and hydrogen-occluded alloys that might be usable as the neutron shielding material were examined. And a wide range of materials, including aluminum alloys that might be usable as the neutron-absorbing material were examined. After screening, the candidate material was determined on the basis of evaluation regarding its adaptabilities as a high-performance neutron-shielding and neutron-absorbing material. This candidate material was manufactured for trial, after which material properties tests, neutron-shielding tests and neutron-absorbing tests were carried out on it. The specifications of this material were thus determined. This research has resulted in materials of good performance; a neutron-shielding material based on ethylene propylene rubber and titanium hydride, and a neutron-absorbing material based on aluminum and titanium hydride. (author)

  7. ASOP, Shield Calculation, 1-D, Discrete Ordinates Transport

    International Nuclear Information System (INIS)

    1993-01-01

    1 - Nature of physical problem solved: ASOP is a shield optimization calculational system based on the one-dimensional discrete ordinates transport program ANISN. It has been used to design optimum shields for space applications of SNAP zirconium-hydride-uranium- fueled reactors and uranium-oxide fueled thermionic reactors and to design beam stops for the ORELA facility. 2 - Method of solution: ASOP generates coefficients of linear equations describing the logarithm of the dose and dose-weight derivatives as functions of position from data obtained in an automated sequence of ANISN calculations. With the dose constrained to a design value and all dose-weight derivatives required to be equal, the linear equations may be solved for a new set of shield dimensions. Since changes in the shield dimensions may cause the linear functions to change, the entire procedure is repeated until convergence is obtained. The detailed calculations of the radiation transport through shield configurations for every step in the procedure distinguish ASOP from other shield optimization computer code systems which rely on multiple component sources and attenuation coefficients to describe the transport. 3 - Restrictions on the complexity of the problem: Problem size is limited only by machine size

  8. Concrete shielding for nuclear ship 'Mutsu'

    International Nuclear Information System (INIS)

    Nagase, Tetsuo; Saito, Tetsuo

    1983-01-01

    The repair works of the shielding for the nuclear ship ''Mutsu'' were completed in August, 1982. For the primary shielding, serpentine concrete was adopted as it contains a large quantity of water required for neutron shielding, and in the secondary shielding at the upper part of the reactor containment vessel, the original shielding was abolished, and the heavy concrete (high water content, high density concrete) which is effective for neutron and gamma-ray shielding was newly adopted. In this report, the design and construction using these shielding concrete are outlined. In September, 1974, Mutsu caused radiation leak during the test, and the cause was found to be the fast neutrons streaming through a gap between the reactor pressure vessel and the primary shielding. The repair works were carried out in the Sasebo Shipyard. The outline of the repair works of the shielding is described. The design condition for the shielding, the design standard for the radiation dose outside and inside the ship, the method of shielding analysis and the performance required for shielding concrete are reported. The selection of materials, the method of construction and mixing ratio, the evaluation of the soundness and properties of concrete, and the works of placing the shielding concrete are outlined. (Kako, I.)

  9. Semi-analytic flux formulas for shielding calculations

    International Nuclear Information System (INIS)

    Wallace, O.J.

    1976-06-01

    A special coordinate system based on the work of H. Ono and A. Tsuro has been used to derive exact semi-analytic formulas for the flux from cylindrical, spherical, toroidal, rectangular, annular and truncated cone volume sources; from cylindrical, spherical, truncated cone, disk and rectangular surface sources; and from curved and tilted line sources. In most of the cases where the source is curved, shields of the same curvature are allowed in addition to the standard slab shields; cylindrical shields are also allowed in the rectangular volume source flux formula. An especially complete treatment of a cylindrical volume source is given, in which dose points may be arbitrarily located both within and outside the source, and a finite cylindrical shield may be considered. Detector points may also be specified as lying within spherical and annular source volumes. The integral functions encountered in these formulas require at most two-dimensional numeric integration in order to evaluate the flux values. The classic flux formulas involving only slab shields and slab, disk, line, sphere and truncated cone sources become some of the many special cases which are given in addition to the more general formulas mentioned above

  10. Revise of a basic data base for shielding design

    International Nuclear Information System (INIS)

    Nakao, Makoto; Takemura, Morio

    2000-03-01

    With use of the two-dimensional discrete ordinates code DORT and the standard groupwise shielding design library JSSTDL produced from the latest evaluated nuclear data library JENDL-3.2, experimental analyses for the representative configurations in the Radial Shield Attenuation Experiment of the JASPER were performed. The results were compared with those obtained with use of traditional method DOT3.5/JSDJ2 for the previous JASPER experimental analyses. In general, the change of the cross section library gives higher results and the change of the transport code gives lower results. Finally the new analysis method gives better agreement with the experimental results and also less deviations of calculational errors between various detectors. Experimental analyses for the thick concrete configuration in the Gap Streaming Experiment of the JASPER was also performed with the new analysis method, after solving the poor agreement found in last year with the original JASPER experimental analyses. The same tendency due to the library change was confirmed with the above mentioned analyses of the Radial Shield Attenuation Experiment. Compilation of the input data necessary for future reanalyses of important configurations in JASPER experiments were continued through the above-mentioned experimental analyses and related informations were added for repletion of the database preserved in a computer disk holding previously accumulated data. Input data descriptions were made for auxiliary routines needed for the experimental analyses and their sample data were compiled and stored in the database. (author)

  11. Optimal design of a composite space shield based on numerical simulations

    International Nuclear Information System (INIS)

    Son, Byung Jin; Yoo, Jeong Hoon; Lee, Min Hyung

    2015-01-01

    In this study, optimal design of a stuffed Whipple shield is proposed by using numerical simulations and new penetration criterion. The target model was selected based on the shield model used in the Columbus module of the international space station. Because experimental results can be obtained only in the low velocity region below 7 km/s, it is required to derive the Ballistic limit curve (BLC) in the high velocity region above 7 km/s by numerical simulation. AUTODYN-2D, the commercial hydro-code package, was used to simulate the nonlinear transient analysis for the hypervelocity impact. The Smoothed particle hydrodynamics (SPH) method was applied to projectile and bumper modeling to represent the debris cloud generated after the impact. Numerical simulation model and selected material properties were validated through a quantitative comparison between numerical and experimental results. A new criterion to determine whether the penetration occurs or not is proposed from kinetic energy analysis by numerical simulation in the velocity region over 7 km/s. The parameter optimization process was performed to improve the protection ability at a specific condition through the Design of experiment (DOE) method and the Response surface methodology (RSM). The performance of the proposed optimal design was numerically verified.

  12. SU-F-E-13: Design and Fabrication of Gynacological Brachytherapy Shielding & Non Shielding Applicators Using Indigenously Developed 3D Printing Machine

    International Nuclear Information System (INIS)

    Shanmugam, S

    2016-01-01

    Purpose: In this innovative work we have developed Gynecological Brachytherapy shielding & Non Shielding Applicators and compared with the commercially available applicators by using the indigenously developed 3D Printing machine. Methods: We have successfully indigenously developed the 3D printing machine. Which contain the 3 dimensional motion platform, Heater unit, base plate, ect… To fabricate the Gynecological Brachytherapy shielding & non shielding applicators the 3D design were developed in the computer as virtual design. This virtual design is made in a CAD computer file using a 3D modeling program. Separate programme for the shielding & non shielding applicators. We have also provided the extra catheter insert provision in the applicator for the multiple catheter. The DICOM file of the applicator were then converted to stereo Lithography file for the 3D printer. The shielding & Non Shielding Applicators were printed on a indigenously developed 3D printer material. The same dimensions were used to develop the applicators in the acrylic material also for the comparative study. A CT scan was performed to establish an infill-density calibration curve as well as characterize the quality of the print such as uniformity and the infill pattern. To commission the process, basic CT and dose properties of the printing materials were measured in photon beams and compared against water and soft tissue. Applicator were then scanned to confirm the placement of multiple catheter position. Finally dose distributions with rescanned CTs were compared with those computer-generated applicators. Results: The doses measured from the ion Chamber and X-Omat film test were within 2%. The shielded applicator reduce the rectal dose comparatively with the non shielded applicator. Conclusion: As of submission 3 unique cylinders have been designed, printed, and tested dosimetrically. A standardizable workflow for commissioning custom 3D printed applicators was codified and will be

  13. SU-F-E-13: Design and Fabrication of Gynacological Brachytherapy Shielding & Non Shielding Applicators Using Indigenously Developed 3D Printing Machine

    Energy Technology Data Exchange (ETDEWEB)

    Shanmugam, S

    2016-06-15

    Purpose: In this innovative work we have developed Gynecological Brachytherapy shielding & Non Shielding Applicators and compared with the commercially available applicators by using the indigenously developed 3D Printing machine. Methods: We have successfully indigenously developed the 3D printing machine. Which contain the 3 dimensional motion platform, Heater unit, base plate, ect… To fabricate the Gynecological Brachytherapy shielding & non shielding applicators the 3D design were developed in the computer as virtual design. This virtual design is made in a CAD computer file using a 3D modeling program. Separate programme for the shielding & non shielding applicators. We have also provided the extra catheter insert provision in the applicator for the multiple catheter. The DICOM file of the applicator were then converted to stereo Lithography file for the 3D printer. The shielding & Non Shielding Applicators were printed on a indigenously developed 3D printer material. The same dimensions were used to develop the applicators in the acrylic material also for the comparative study. A CT scan was performed to establish an infill-density calibration curve as well as characterize the quality of the print such as uniformity and the infill pattern. To commission the process, basic CT and dose properties of the printing materials were measured in photon beams and compared against water and soft tissue. Applicator were then scanned to confirm the placement of multiple catheter position. Finally dose distributions with rescanned CTs were compared with those computer-generated applicators. Results: The doses measured from the ion Chamber and X-Omat film test were within 2%. The shielded applicator reduce the rectal dose comparatively with the non shielded applicator. Conclusion: As of submission 3 unique cylinders have been designed, printed, and tested dosimetrically. A standardizable workflow for commissioning custom 3D printed applicators was codified and will be

  14. Radiation shielding material

    International Nuclear Information System (INIS)

    Kawakubo, Takamasa; Yamada, Fumiyuki; Nakazato, Kenjiro.

    1976-01-01

    Purpose: To provide a material, which is used for printing a samples name and date on an X-ray photographic film at the same time an X-ray radiography. Constitution: A radiation shielding material of a large mass absorption coefficient such as lead oxide, barium oxide, barium sulfate, etc. is added to a solution of a radiation permeable substance capable of imparting cold plastic fluidity (such as microcrystalline wax, paraffin, low molecular polyethylene, polyvinyl chloride, etc.). The resultant system is agitated and then cooled, and thereafter it is press fitted to or bonded to a base in the form of a film of a predetermined thickness. This radiation shielding layer is scraped off by using a writing tool to enter information to be printed in a photographic film, and then it is laid over the film and exposed to X-radiation to thereby print the information on the film. (Seki, T.)

  15. Shielding container

    International Nuclear Information System (INIS)

    Darling, K.A.M.

    1981-01-01

    A shielding container incorporates a dense shield, for example of depleted uranium, cast around a tubular member of curvilinear configuration for accommodating a radiation source capsule. A lining for the tubular member, in the form of a close-coiled flexible guide, provides easy replaceability to counter wear while the container is in service. Container life is extended, and maintenance costs are reduced. (author)

  16. Topographic evidence for shield volcanism on Io

    International Nuclear Information System (INIS)

    Moore, J.M.; Mcewen, A.S.; Albin, E.F.; Greeley, R.

    1986-01-01

    Similarities between terrestrial shield volcanoes and a volcano on Io observed in Voyager I imagery of the satellite at 30 0 S, 246 0 W are delineated. A photoclinometry model was used to numerically estimate the slope based on the Minnaert photometric function. The slope values are accurate to within 10 deg on the sun-facing slope and 1 deg on the shadow side. As found with shield volcanoes, the feature has a central edifice, 40-50 km in diameter, and a broad, elliptical base, 77 x 90 km across. The summit of the Io volcano is 2.2-2.8 km above the surrounding plane and contains a caldera about 5 km in diameter. The similarity in shape between basaltic terrestrial shield volcanoes and the Io volcano indicates that the Io feature may also be composed of basalt. The composition could be sulfur if the heat flow was under 0.05 W/sq m, as it might have been in later stages of formation. 9 references

  17. SP-100 GES/NAT radiation shielding systems design and development testing

    International Nuclear Information System (INIS)

    Disney, R.K.; Kulikowski, H.D.; McGinnis, C.A.; Reese, J.C.; Thomas, K.; Wiltshire, F.

    1991-01-01

    Advanced Energy Systems (AES) of Westinghouse Electric Corporation is under subcontract to the General Electric Company to supply nuclear radiation shielding components for the SP-100 Ground Engineering System (GES) Nuclear Assembly Test to be conducted at Westinghouse Hanford Company at Richland, Washington. The radiation shielding components are integral to the Nuclear Assembly Test (NAT) assembly and include prototypic and non-prototypic radiation shielding components which provide prototypic test conditions for the SP-100 reactor subsystem and reactor control subsystem components during the GES/NAT operations. W-AES is designing three radiation shield components for the NAT assembly; a prototypic Generic Flight System (GFS) shield, the Lower Internal Facility Shield (LIFS), and the Upper Internal Facility Shield (UIFS). This paper describes the design approach and development testing to support the design, fabrication, and assembly of these three shield components for use within the vacuum vessel of the GES/NAT. The GES/NAT shields must be designed to operate in a high vacuum which simulates space operations. The GFS shield and LIFS must provide prototypic radiation/thermal environments and mechanical interfaces for reactor system components. The NAT shields, in combination with the test facility shielding, must provide adequate radiation attenuation for overall test operations. Special design considerations account for the ground test facility effects on the prototypic GFS shield. Validation of the GFS shield design and performance will be based on detailed Monte Carlo analyses and developmental testing of design features. Full scale prototype testing of the shield subsystems is not planned

  18. Elastomeric neutron shielding material and process of production

    International Nuclear Information System (INIS)

    John, G.; Knorr, W.

    1987-01-01

    Elastomeric neutron shielding material made of plastic with high hydrogen content, characterized in that the shielding material is a polymeric reaction product of a reaction between (a) polyol on the base of polybutadiene which compares with polyethylene with regard to hydrogen content, and (b) aliphatic diisocyanate, and in that the hydrogen content is higher than 8 weight per cent. (orig.) [de

  19. Concrete radiation shielding

    International Nuclear Information System (INIS)

    Kaplan, M.F.

    1989-01-01

    The increased use of nuclear energy has given rise to a growth in the amount of artificially produced radiation and radioactive materials. The design and construction of shielding to protect people, equipment and structures from the effects of radiation has never been more important. Experience has shown that concrete is an effective, versatile and economical material for the construction of radiation shielding. This book provides information on the principles governing the interaction of radiation with matter and on relevant nuclear physics to give the engineer an understanding of the design and construction of concrete shielding. It covers the physical, mechanical and nuclear properties of concrete; the effects of elevated temperatures and possible damage to concrete due to radiation; basic procedures for the design of concrete radiation shields and finally the special problems associated with their construction and cost. Although written primarily for engineers concerned with the design and construction of concrete shielding, the book also reviews the widely scattered data and information available on this subject and should therefore be of interest to students and those wishing to research further in this field. (author)

  20. Radiation protection and shielding design - Strengthening the link

    International Nuclear Information System (INIS)

    Hobson, J.; Cooper, A.

    2005-01-01

    The improvement in quality and flexibility of shielding methods and data has been progressive and beneficial in opening up new opportunities for optimising radiation protection in design. The paper describes how these opportunities can best be seized by taking a holistic view of radiation protection, with shielding design being an important component part. This view is best achieved by enhancing the role of 'shielding assessors' so that they truly become 'radiation protection designers'. The increase in speed and efficiency of shielding calculations has been enormous over the past decades. This has raised the issue of how the assessor's time now can be best utilised; pursuing ever greater precision and accuracy in shielding/dose assessments, or improving the contribution that shielding assessment makes to radiological protection and cost-effective design. It is argued in this paper that the latter option is of great importance and will give considerable benefits. Shielding design needs to form part of a larger radiation protection perspective based on a deep understanding/appreciation of the opportunities and constraints of operators and designers, enabling minimal design iterations, cost optimisation of alternative designs (with a 'lifetime' perspective) and improved realisation of design intent in operations. The future of shielding design development is argued to be not in improving the 'tool-kit', but in enhanced understanding of the 'product' and the 'process' for achieving it. The holistic processes being developed in BNFL to realise these benefits are described in the paper and will be illustrated by case studies. (authors)

  1. Gonad shielding in diagnostic radiology

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    The use of gonad shielding is an important radiation protection technique, intended to reduce unnecessary x-ray exposure of the gonads of patients from diagnostic x-ray procedures. The types of gonad shields in use are discussed as are the types of diagnostic examinations that should include gonad shielding. It was found that when properly used, most shields provided substantial gonad dose reductions

  2. Water and Regolith Shielding for Surface Reactor Missions

    Science.gov (United States)

    Poston, David I.; Ade, Brian J.; Sadasivan, Pratap; Leichliter, Katrina J.; Dixon, David D.

    2006-01-01

    This paper investigates potential shielding options for surface power fission reactors. The majority of work is focused on a lunar shield that uses a combination of water in stainless-steel cans and lunar regolith. The major advantage of a water-based shield is that development, testing, and deployment should be relatively inexpensive. This shielding approach is used for three surface reactor concepts: (1) a moderated spectrum, NaK cooled, Hastalloy/UZrH reactor, (2) a fast-spectrum, NaK-cooled, SS/UO2 reactor, and (3) a fast-spectrum, K-heat-pipe-cooled, SS/UO2 reactor. For this study, each of these reactors is coupled to a 25-kWt Stirling power system, designed for 5 year life. The shields are designed to limit the dose both to the Stirling alternators and potential astronauts on the surface. The general configuration used is to bury the reactor, but several other options exist as well. Dose calculations are presented as a function of distance from reactor, depth of buried hole, water boron concentration (if any), and regolith repacked density.

  3. Water and Regolith Shielding for Surface Reactor Missions

    International Nuclear Information System (INIS)

    Poston, David I.; Sadasivan, Pratap; Dixon, David D.; Ade, Brian J.; Leichliter, Katrina J.

    2006-01-01

    This paper investigates potential shielding options for surface power fission reactors. The majority of work is focused on a lunar shield that uses a combination of water in stainless-steel cans and lunar regolith. The major advantage of a water-based shield is that development, testing, and deployment should be relatively inexpensive. This shielding approach is used for three surface reactor concepts: (1) a moderated spectrum, NaK cooled, Hastalloy/UZrH reactor, (2) a fast-spectrum, NaK-cooled, SS/UO2 reactor, and (3) a fast-spectrum, K-heat-pipe-cooled, SS/UO2 reactor. For this study, each of these reactors is coupled to a 25-kWt Stirling power system, designed for 5 year life. The shields are designed to limit the dose both to the Stirling alternators and potential astronauts on the surface. The general configuration used is to bury the reactor, but several other options exist as well. Dose calculations are presented as a function of distance from reactor, depth of buried hole, water boron concentration (if any), and regolith repacked density

  4. Fe-based bulk metallic glasses used for magnetic shielding

    Energy Technology Data Exchange (ETDEWEB)

    Serban, Va; Codrean, C; UTu, D [Politehnica University of Timisoara, Depart for Materials Science and Welding, 1, M. Viteazu Bvd., 300222, Timisoara (Romania); ErcuTa, A, E-mail: serban@mec.upt.r [West University of Timisoara, Faculty of Physics, 4, Vasile Parvan Bdv., Timisoara 300223 (Romania)

    2009-01-01

    The casting in complex shapes (tubular) and the main magnetic properties of bulk metallic glasses (BMG) alloys from the ferromagnetic Fe-Cr-Ni-Ga-P-Si-C system, with a small addition of Ni (3%) were studied. Samples as rods and sockets having the thickness up to 1 mm were obtained from master alloys by melt injection by low cooling rates into a Cu mold and annealed in order to ensure adequate magnetic requirements. The structure was examined by X-ray diffraction (XRD) and the basic magnetic properties (coercivity, magnetic remanence, initial susceptibility, etc.) were determined by conventional low frequency induction method. The experimental investigations on producing of BMG ferromagnetic alloys with 3% Ni show the possibility to obtain magnetic shields of complex shape with satisfactory magnetic properties. The presence of Ni does not affect the glass forming ability, but reduce the shielding capacity.

  5. Study on shielded pump system failure analysis method based on Bayesian network

    International Nuclear Information System (INIS)

    Bao Yilan; Huang Gaofeng; Tong Lili; Cao Xuewu

    2012-01-01

    This paper applies Bayesian network to the system failure analysis, with an aim to improve knowledge representation of the uncertainty logic and multi-fault states in system failure analysis. A Bayesian network for shielded pump failure analysis is presented, conducting fault parameter learning, updating Bayesian network parameter based on new samples. Finally, through the Bayesian network inference, vulnerability in this system, the largest possible failure modes, and the fault probability are obtained. The powerful ability of Bayesian network to analyze system fault is illustrated by examples. (authors)

  6. Design experience: CRBRP radiation shielding

    International Nuclear Information System (INIS)

    Disney, R.K.; Chan, T.C.; Gallo, F.G.; Hedgecock, L.R.; McGinnis, C.A.; Wrights, G.N.

    1978-11-01

    The Clinch River Breeder Reactor Plant (CRBRP) is being designed as a fast breeder demonstration project in the U.S. Liquid Metal Fast Breeder Reactor (LMFBR) program. Radiation shielding design of the facility consists of a comprehensive design approach to assure compliance with design and government regulatory requirements. Studies conducted during the CRBRP design process involved the aspects of radiation shielding dealing with protection of components, systems, and personnel from radiation exposure. Achievement of feasible designs, while considering the mechanical, structural, nuclear, and thermal performance of the component or system, has required judicious trade-offs in radiation shielding performance. Specific design problems which have been addressed are in-vessel radial shielding to protect permanent core support structures, flux monitor system shielding to isolate flux monitoring systems for extraneous background sources, reactor vessel support shielding to allow personnel access to the closure head during full power operation, and primary heat transport system pipe chaseway shielding to limit intermediate heat transport system sodium system coolant activation. The shielding design solutions to these problems defined a need for prototypic or benchmark experiments to provide assurance of the predicted shielding performance of selected design solutions and the verification of design methodology. Design activities of CRBRP plant components an systems, which have the potential for radiation exposure of plant personnel during operation or maintenance, are controlled by a design review process related to radiation shielding. The program implements design objectives, design requirements, and cost/benefit guidelines to assure that radiation exposures will be ''as low as reasonably achievable''

  7. Características de las cataratas en pacientes diabéticos durante un año en el Centro Oftalmológico de Guyana

    Directory of Open Access Journals (Sweden)

    Aymed de la Caridad Rodríguez Pargas

    Full Text Available Objetivo: caracterizar las cataratas en los pacientes diabéticos en la población de Guyana y determinar los resultados visuales de la cirugía. Métodos: se realizó un estudio observacional descriptivo prospectivo a 310 pacientes quienes acudieron al Centro Oftalmológico de Guyana en el período comprendido de septiembre de 2012 a septiembre de 2013, y que cumplieron con los criterios de inclusión, en los que se utilizó como tratamiento la cirugía de catarata con la técnica de extracción extracapsular tunelizada y la colocación de lente intraocular. La historia clínica individual constituyó la fuente primaria de la investigación. Se realizó un análisis descriptivo de todas las variables para obtener sus porcentajes. Resultados: predominaron los pacientes masculinos mayores de 60 años de edad, con cataratas totales y visión de cuenta dedos. El 27,5 % no presentó retinopatía diabética, y como complicación prevaleció la opacidad de cápsula posterior. Conclusiones: después de la cirugía de catarata, el 85 % mejoró su visión, por lo que se recomendó la realización de la cirugía, tanto con fines visuales como terapéuticos.

  8. Calculation of a concrete shielding for an ILU-8 D electron accelerator

    International Nuclear Information System (INIS)

    Helal, A.; Imam, A.

    1996-01-01

    A concrete shielding for an electron accelerator of 1 MeV is suggested to replace its structural steel shielding. The thickness of such a shield is calculated. The calculational model used is based on standard and transmission curves given in the literature. The calculated concrete shielding is generally adequate to attenuate the accelerator produced radiation to a level 1 μ Gy/h or less at any point outside of the vault enclosure. 5 figs

  9. Calculation of a concrete shielding for an ILU-8 D electron accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Helal, A [Nuclear Research Center, AEA, Cairo (Egypt); Imam, A [National Center for Nuclear Safety and Radiation Control, AEA, Cairo (Egypt)

    1997-12-31

    A concrete shielding for an electron accelerator of 1 MeV is suggested to replace its structural steel shielding. The thickness of such a shield is calculated. The calculational model used is based on standard and transmission curves given in the literature. The calculated concrete shielding is generally adequate to attenuate the accelerator produced radiation to a level 1 {mu} Gy/h or less at any point outside of the vault enclosure. 5 figs.

  10. Radiation shielding calculation using MCNP

    International Nuclear Information System (INIS)

    Masukawa, Fumihiro

    2001-01-01

    To verify the Monte Carlo code MCNP4A as a tool to generate the reference data in the shielding designs and the safety evaluations, various shielding benchmark experiments were analyzed using this code. These experiments were categorized in three types of the shielding subjects; bulk shielding, streaming, and skyshine. For the variance reduction technique, which is indispensable to get meaningful results with the Monte Carlo shielding calculation, we mainly used the weight window, the energy dependent Russian roulette and spitting. As a whole, our analyses performed enough small statistical errors and showed good agreements with these experiments. (author)

  11. Overview of first wall/blanket/shield technology

    International Nuclear Information System (INIS)

    Nygren, R.E.

    1983-04-01

    This brief overview of first wall, blanket, and shield technology focuses first on changes and trends in important design issues from the 1970's to the 1980's, then on current perceptions of critical issues in first wall, blanket, and shield design and related technology. The emphasis is on base technology rather than either systems engineering or materials development, on the two primary confinement systems, tokamaks and mirrors, and on production of electricity as the primary goal for development

  12. MMW [multimegawatt] shielding design and analysis

    International Nuclear Information System (INIS)

    Olson, A.P.

    1988-01-01

    Reactor shielding for multimegawatt (MMW) space power must satisfy a mass constraint as well as performance specifications for neutron fluence and gamma dose. A minimum mass shield is helpful in attaining the launch mass goal for the entire vehicle, because the shield comprises about 1% to 2% of the total vehicle mass. In addition, the shield internal heating must produce tolerable temperatures. The analysis of shield performance for neutrons and gamma rays is emphasized. Topics addressed include cross section preparation for multigroup 2D S/sub n/-transport analyses, and the results of parametric design studies on shadow shield performance and mass versus key shield design variables such as cone angle, number, placement, and thickness of layers of tungsten, and shield top radius. Finally, adjoint methods are applied to the shield in order to spatially map its relative contribution to dose reduction, and to provide insight into further design optimization. 7 refs., 2 figs., 3 tabs

  13. Development of epoxy resin-type neutron shielding materials (I)

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Soo Haeng; Kim, Ik Soo; Shin, Young Joon; Do, Jae Bum; Ro, Seung Gy

    1997-12-01

    Because the exposure to radiation in the nuclear facilities can be fatal to human, it is important to reduce the radiation dose level to a tolerable level. The purpose of this study is to develop highly effective neutron shielding materials for the shipping and storage cask of radioactive materials or in the nuclear /radiation facilities. On this study, we developed epoxy resin based neutron shielding materials and their various materials properties, including neutron shielding ability, fire resistance, combustion characteristics, radiation resistance, thermal and mechanical properties were evaluated experimentally. (author). 31 refs., 22 tabs., 17 figs.

  14. Preliminary shielding analysis of VHTR reactors

    International Nuclear Information System (INIS)

    Flaspoehler, Timothy M.; Petrovic, Bojan

    2011-01-01

    Over the last 20 years a number of methods have been established for automated variance reduction in Monte Carlo shielding simulations. Hybrid methods rely on deterministic adjoint and/or forward calculations to generate these parameters. In the present study, we use the FWCADIS method implemented in MAVRIC sequence of the SCALE6 package to perform preliminary shielding analyses of a VHTR reactor. MAVRIC has been successfully used by a number of researchers for a range of shielding applications, including modeling of LWRs, spent fuel storage, radiation field throughout a nuclear power plant, study of irradiation facilities, and others. However, experience in using MAVRIC for shielding studies of VHTRs is more limited. Thus, the objective of this work is to contribute toward validating MAVRIC for such applications, and identify areas for potential improvement. A simplified model of a prismatic VHTR has been devised, based on general features of the 600 MWt reactor considered as one of the NGNP options. Fuel elements have been homogenized, and the core region is represented as an annulus. However, the overall mix of materials and the relatively large dimensions of the spatial domain challenging the shielding simulations have been preserved. Simulations are performed to evaluate fast neutron fluence, dpa, and other parameters of interest at relevant positions. The paper will investigate and discuss both the effectiveness of the automated variance reduction, as well as applicability of physics model from the standpoint of specific VHTR features. (author)

  15. Development of shielding design analysis system

    International Nuclear Information System (INIS)

    Tada, Keiko; Shiraki, Takako

    2001-03-01

    The aim of this work is to develop insufficient auxiliary routines which manage input and output data and interface the main codes and to establish a shielding design analysis system on work stations (SUN, DEC). In shielding design analyses, one- and two- dimensional (1-D and 2-D) transport Sn codes are used mainly with some auxiliary codes which generate input data of Sn calculation and edit Sn calculation outputs. The main transport calculation codes can be obtained from the Code Center of RIST (Research Organization for Information Science and Technology). In this work, peripheral codes are developed to generate cross sections, produce Sn quadrature sets, edit calculation outputs or draw contour figures. In shielding calculations around a reactor, the boot-strapping technique is often employed to treat a large area extending from the core to the biological shield to improve the calculation accuracy. When a three-dimensional (3-D) calculation for a complex geometry with shielding defects, 2-D and 3-D coupling calculation is employed frequently. To use this coupling method conversion cods are prepared which read flux file from DORT and prepare an external boundary source file for the 2-D or the 3-D calculation codes. For further conveniences well used data such as the Sn quadrature sets, the dose rate conversion factors, the reaction cross section sets are stored as a data base and code manuals including sample inputs of typical problems are prepared which are comprehensible to beginners. (author)

  16. LOFT shield tank steady state temperatures with addition of gamma and neutron shielding

    International Nuclear Information System (INIS)

    Kyllingstad, G.

    1977-01-01

    The effect of introducing a neutron and gamma shield into the annulus between the reactor vessel and the shield tank is analyzed. This addition has been proposed in order to intercept neutron streaming up the annulus during nuclear operations. Its installation will require removal of approximately 20- 1 / 2 inches of stainless steel foil insulation at the top of the annulus. The resulting conduction path is believed to result in increased water temperatures within the shield tank, possibly beyond the 150 0 F limit, and/or cooling of the reactor vessel nozzles such that adverse thermal stresses would be generated. A two dimensional thermal analysis using the finite element code COUPLE/MOD2 was done for the shield tank system illustrated in the figure (1). The reactor was assumed to be at full power, 55 MW (th), with a loop flow rate of 2.15 x 10 6 lbm/hr (268.4 kg/s) at 2250 psi (15.51 MPa). Calculations indicate a steady state shield tank water temperature of 140 0 F (60 0 C). This is below the 150 0 F (65.56 0 C) limit. Also, no significant changes in thermal gradients within the nozzle or reactor vessel wall are generated. A spacer between the gamma shield and the shield tank is recommended, however, in order to ensure free air circulation through the annulus

  17. Nonlinear Effects in Transformation Optics-Based Metamaterial Shields for Counter Directed Energy Weapon Defense

    Science.gov (United States)

    2016-06-01

    employs the in- variance of the Maxwell equations under coordinate transformations to convert the free- space wave solutions in a coordinate... ENERGY WEAPON DEFENSE by Jacob D. Thompson June 2016 Thesis Co-Advisors: James Luscombe Brett Borden Approved for public release; distribution is...2014 to 06-17-2016 4. TITLE AND SUBTITLE NONLINEAR EFFECTS IN TRANSFORMATION OPTICS-BASED METAMATE- RIAL SHIELDS FOR COUNTER DIRECTED ENERGY WEAPON

  18. Concrete shielding for nuclear ship 'Mutsu'

    International Nuclear Information System (INIS)

    Nagase, Tetsuo; Nakajima, Tadao; Okumura, Tadahiko; Saito, Tetsuo

    1983-01-01

    The nuclear ship ''Mutsu'' was constructed in 1970 as the fourth in the world. On September 1, 1974, during the power raising test in the Pacific Ocean, radiation leak was detected. As the result of investigation, it was found that the cause was the fast neutrons streaming through the gap between the reactor pressure vessel and the primary shield. In order to repair the shielding facility, the Japan Nuclear Ship Research Development Agency carried out research and development and shielding design. It was decided to adopt serpentine concrete for the primary shield, which is the excellent moderator of fast neutrons even at high temperature, and heavy concrete for the secondary shield, which is effective for shielding both gamma ray and neutron beam. The repair of shielding was carried out in the Sasebo Shipyard, and completed in August, 1982. The outline of the repair work is reported. The weight increase was about 300 t. The conditions of the shielding design, the method of shielding analysis, the performance required for the shielding concrete, the preliminary experiment on heavy concrete and the construction works of serpentine concrete and heavy concrete are described. (Kako, I.)

  19. Accelerator shielding benchmark problems

    International Nuclear Information System (INIS)

    Hirayama, H.; Ban, S.; Nakamura, T.

    1993-01-01

    Accelerator shielding benchmark problems prepared by Working Group of Accelerator Shielding in the Research Committee on Radiation Behavior in the Atomic Energy Society of Japan were compiled by Radiation Safety Control Center of National Laboratory for High Energy Physics. Twenty-five accelerator shielding benchmark problems are presented for evaluating the calculational algorithm, the accuracy of computer codes and the nuclear data used in codes. (author)

  20. Ground-based simulations of cosmic ray heavy ion interactions in spacecraft and planetary habitat shielding materials

    Science.gov (United States)

    Miller, J.; Zeitlin, C.; Heilbronn, L.; Borak, T.; Carter, T.; Frankel, K. A.; Fukumura, A.; Murakami, T.; Rademacher, S. E.; Schimmerling, W.; hide

    1998-01-01

    This paper surveys some recent accelerator-based measurements of the nuclear fragmentation of high energy nuclei in shielding and tissue-equivalent materials. These data are needed to make accurate predictions of the radiation field produced at depth in spacecraft and planetary habitat shielding materials and in the human body by heavy charged particles in the galactic cosmic radiation. Projectile-target combinations include 1 GeV/nucleon 56Fe incident on aluminum and graphite and 600 MeV/nucleon 56Fe and 290 MeV/nucleon 12C on polyethylene. We present examples of the dependence of fragmentation on material type and thickness, of a comparison between data and a fragmentation model, and of multiple fragments produced along the beam axis.

  1. HPGe detector shielding adjustment

    International Nuclear Information System (INIS)

    Trnkova, L.; Rulik, P.

    2008-01-01

    Low-level background shielding of HPGe detectors is used mainly for environmental samples with very low content of radionuclides. National Radiation Protection Institute (SURO) in Prague is equipped with 14 HPGe detectors with relative efficiency up to 150%. The detectors are placed in a room built from materials with low content of natural radionuclides and equipped with a double isolation of the floor against radon. Detectors themselves are placed in lead or steel shielding. Steel shielding with one of these detectors with relative efficiency of 100% was chosen to be rebuilt to achieve lower minimum detectable activity (MDA). Additional lead and copper shielding was built up inside the original steel shielding to reduce the volume of the inner space and filled with nitrogen by means of evaporating liquid nitrogen. The additional lead and copper shielding, consequent reduction of the inner volume and supply of evaporated nitrogen, caused a decrease of the background count and accordingly MDA values as well. The effect of nitrogen evaporation on the net areas of peaks belonging to radon daughters is significant. The enhanced shielding adjustment has the biggest influence in low energy range, what can be seen in collected data. MDA values in energy range from 30 keV to 400 keV decreased to 0.65-0.85 of original value, in energy range from 400 keV to 2 MeV they fell to 0.70-0.97 of original value. (authors)

  2. External dosimetry sources and shielding

    International Nuclear Information System (INIS)

    Calisto, Washington

    1994-01-01

    A definition of external dosimetry r external sources dosimetry,physical and mathematical treatment of the interaction of gamma radiation with a minimal area in that direction. Concept of attenuation coefficient, cumulated effect by polyenergetic sources, exposition rate, units, cumulated dose,shielding, foton shielding, depth calculation, materials used for shielding.Beta shielding, consideration of range and maximum β energy , low stopping radiation by use of low Z shielding. Tables for β energy of β emitters, I (tau) factor, energy-range curves for β emitters in aqueous media, gamma attenuation factors for U, W and Pb. Y factor for bone tissue,muscle and air, build-up factors

  3. The shielding performance of multilayer composite shielding structures to 14.8 MeV fast neutrons

    International Nuclear Information System (INIS)

    Shen Zhiqiang; Kang Qing; Xu Jun; Wang Zhenggang; Lu Nan

    2014-01-01

    Cement-based round thin-layer samples mixed with 30% quality content of barite, and 20% quality content of carbide boron has Prepared, the same-diameter sliced samples of pure graphite and pure polyethylene has cut, then, samples combination and cross stack order has designed, formed four species Multilayer Composite shield structure, at last, neutron attenuation measurements has been done by experimental system of using 14.8 MeV neutrons from the 5SDH-2 accelerator and long counter composition, penetrating rate of samples and the shield structure to 14.8 MeV fast neutron has tested, and attenuation section has calculated. Results show that 14.8 MeV fast neutrons to higher penetration rates of thin layer samples, attenuation cross section of samples distinguish small between each other, must be increasing the thickness of the samples to reduce the experimental uncertainty; through composed of attenuation cross section and thickness parameters of composite structure, can more accurately predict the shielding ability of composite structures, error between calculation results and experimental results in 4%. (authors)

  4. Self-shielding models of MICROX-2 code: Review and updates

    International Nuclear Information System (INIS)

    Hou, J.; Choi, H.; Ivanov, K.N.

    2014-01-01

    Highlights: • The MICROX-2 code has been improved to expand its application to advanced reactors. • New fine-group cross section libraries based on ENDF/B-VII have been generated. • Resonance self-shielding and spatial self-shielding models have been improved. • The improvements were assessed by a series of benchmark calculations against MCNPX. - Abstract: The MICROX-2 is a transport theory code that solves for the neutron slowing-down and thermalization equations of a two-region lattice cell. The MICROX-2 code has been updated to expand its application to advanced reactor concepts and fuel cycle simulations, including generation of new fine-group cross section libraries based on ENDF/B-VII. In continuation of previous work, the MICROX-2 methods are reviewed and updated in this study, focusing on its resonance self-shielding and spatial self-shielding models for neutron spectrum calculations. The improvement of self-shielding method was assessed by a series of benchmark calculations against the Monte Carlo code, using homogeneous and heterogeneous pin cell models. The results have shown that the implementation of the updated self-shielding models is correct and the accuracy of physics calculation is improved. Compared to the existing models, the updates reduced the prediction error of the infinite multiplication factor by ∼0.1% and ∼0.2% for the homogeneous and heterogeneous pin cell models, respectively, considered in this study

  5. Method for dismantling shields

    International Nuclear Information System (INIS)

    Fukuzawa, Rokuro; Kondo, Nobuhiro; Kamiyama, Yoshinori; Kawasato, Ken; Hiraga, Tomoaki.

    1990-01-01

    The object of the present invention is to enable operators to dismantle shieldings contaminated by radioactivity easily and in a short period of time without danger of radiation exposure. A plurality of introduction pipes are embedded previously to the shielding walls of shielding members which contain a reactor core in a state where both ends of the introduction pipes are in communication with the outside. A wire saw is inserted into the introduction pipes to cut the shieldings upon dismantling. Then, shieldings can be dismantled easily in a short period of time with no radiation exposure to operator's. Further, according to the present invention, since the wire saw can be set easily and a large area can be cut at once, operation efficiency is improved. Further, since remote control is possible, cutting can be conducted in water and complicated places of the reactor. Biting upon starting the wire saw in the introduction pipe is reduced to facilitate startup for the rotation. (I.S.)

  6. SU-C-BRB-02: Symmetric and Asymmetric MLC Based Lung Shielding and Dose Optimization During Translating Bed TBI

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, S; Kakakhel, MB [Pakistan Institute of Engineering & Applied Sciences (PIEAS), Islamabad (Pakistan); Ahmed, SBS; Hussain, A [Aga Khan University Hospital (AKUH), Karachi (Pakistan)

    2015-06-15

    Purpose: The primary aim was to introduce a dose optimization method for translating bed total body irradiation technique that ensures lung shielding dynamically. Symmetric and asymmetric dynamic MLC apertures were employed for this purpose. Methods: The MLC aperture sizes were defined based on the radiological depth values along the divergent ray lines passing through the individual CT slices. Based on these RD values, asymmetrically shaped MLC apertures were defined every 9 mm of the phantom in superior-inferior direction. Individual MLC files were created with MATLAB™ and were imported into Eclipse™ treatment planning system for dose calculations. Lungs can be shielded to an optimum level by reducing the MLC aperture width over the lungs. The process was repeated with symmetrically shaped apertures. Results: Dose-volume histogram (DVH) analysis shows that the asymmetric MLC based technique provides better dose coverage to the body and optimum shielding of the lungs compared to symmetrically shaped beam apertures. Midline dose homogeneity is within ±3% with asymmetric MLC apertures whereas it remains within ±4.5% with symmetric ones (except head region where it drops down to −7%). The substantial over and under dosage of ±5% at tissue interfaces has been reduced to ±2% with asymmetric MLC technique. Lungs dose can be reduced to any desired limit. In this experiment lungs dose was reduced to 80% of the prescribed dose, as was desired. Conclusion: The novel asymmetric MLC based technique assures optimum shielding of OARs (e.g. lungs) and better 3-D dose homogeneity and body-dose coverage in comparison with the symmetric MLC aperture optimization. The authors acknowledge the financial and infrastructural support provided by Pakistan Institute of Engineering & Applied Sciences (PIEAS), Islamabad and Aga Khan University Hospital (AKUH), Karachi during the course of this research project. Authors have no conflict of interest with any national / international

  7. Magnetic shield effect simulation of superconducting film shield covering directly coupled HTS dc-SQUID magnetometer

    International Nuclear Information System (INIS)

    Terauchi, N.; Noguchi, S.; Igarashi, H.

    2011-01-01

    A superconducting film shield over a SQUID ring improves the robustness of the SQUID with respect to magnetic noise. Supercurrent in the SQUID magnetometer and the superconducting film shield were simulated. The superconducting film shield reduces the influence of the external magnetic field on the SQUID ring. An HTS SQUID is a high sensitive magnetic sensor. In recent years, the HTS SQUID is widely used in various applications. In some applications, high robustness with respect to magnetic noise is required to realize stable operation at outside of a magnetic shielding room. The target of this paper is a directly coupled HTS dc-SQUID magnetometer. To enhance the robustness of the SQUID magnetometer, use of a superconducting thin film shield has been proposed. The magnetic field directly penetrating the SQUID ring causes the change of the critical current of Josephson junction, and then the SQUID magnetometer transitions into inoperative state. In order to confirm the magnetic shield effect of the superconducting film shield, electromagnetic field simulation with 3D edge finite element method was performed. To simulate the high temperature superconductor, E-J characteristics and c-axis anisotropy are considered. To evaluate the effect of the superconducting film shield, an external magnetic field which is supposed to be a magnetic noise is applied. From the simulation results, the time transition of the magnetic flux penetrating the SQUID ring is investigated and the effect of the superconducting film shield is confirmed. The amplitude of the magnetic flux penetrating the SQUID ring can be reduced to about one-sixth since the superconducting film shield prevents the magnetic noise from directly penetrating the SQUID ring.

  8. Shieldings for X-ray radiotherapy facilities calculated by computer

    International Nuclear Information System (INIS)

    Pedrosa, Paulo S.; Farias, Marcos S.; Gavazza, Sergio

    2005-01-01

    This work presents a methodology for calculation of X-ray shielding in facilities of radiotherapy with help of computer. Even today, in Brazil, the calculation of shielding for X-ray radiotherapy is done based on NCRP-49 recommendation establishing a methodology for calculating required to the elaboration of a project of shielding. With regard to high energies, where is necessary the construction of a labyrinth, the NCRP-49 is not very clear, so that in this field, studies were made resulting in an article that proposes a solution to the problem. It was developed a friendly program in Delphi programming language that, through the manual data entry of a basic design of architecture and some parameters, interprets the geometry and calculates the shields of the walls, ceiling and floor of on X-ray radiation therapy facility. As the final product, this program provides a graphical screen on the computer with all the input data and the calculation of shieldings and the calculation memory. The program can be applied in practical implementation of shielding projects for radiotherapy facilities and can be used in a didactic way compared to NCRP-49.

  9. Dynamic Test Method Based on Strong Electromagnetic Pulse for Electromagnetic Shielding Materials with Field-Induced Insulator-Conductor Phase Transition

    Science.gov (United States)

    Wang, Yun; Zhao, Min; Wang, Qingguo

    2018-01-01

    In order to measure the pulse shielding performance of materials with the characteristic of field-induced insulator-conductor phase transition when materials are used for electromagnetic shielding, a dynamic test method was proposed based on a coaxial fixture. Experiment system was built by square pulse source, coaxial cable, coaxial fixture, attenuator, and oscilloscope and insulating components. S11 parameter of the test system was obtained, which suggested that the working frequency ranges from 300 KHz to 7.36 GHz. Insulating performance is good enough to avoid discharge between conductors when material samples is exposed in the strong electromagnetic pulse field up to 831 kV/m. This method is suitable for materials with annular shape, certain thickness and the characteristic of field-induced insulator-conductor phase transition to get their shielding performances of strong electromagnetic pulse.

  10. Passive magnetic shielding in MRI-Linac systems

    Science.gov (United States)

    Whelan, Brendan; Kolling, Stefan; Oborn, Brad M.; Keall, Paul

    2018-04-01

    Passive magnetic shielding refers to the use of ferromagnetic materials to redirect magnetic field lines away from vulnerable regions. An application of particular interest to the medical physics community is shielding in MRI systems, especially integrated MRI-linear accelerator (MRI-Linac) systems. In these systems, the goal is not only to minimize the magnetic field in some volume, but also to minimize the impact of the shield on the magnetic fields within the imaging volume of the MRI scanner. In this work, finite element modelling was used to assess the shielding of a side coupled 6 MV linac and resultant heterogeneity induced within the 30 cm diameter of spherical volume (DSV) of a novel 1 Tesla split bore MRI magnet. A number of different shield parameters were investigated; distance between shield and magnet, shield shape, shield thickness, shield length, openings in the shield, number of concentric layers, spacing between each layer, and shield material. Both the in-line and perpendicular MRI-Linac configurations were studied. By modifying the shield shape around the linac from the starting design of an open ended cylinder, the shielding effect was boosted by approximately 70% whilst the impact on the magnet was simultaneously reduced by approximately 10%. Openings in the shield for the RF port and beam exit were substantial sources of field leakage; however it was demonstrated that shielding could be added around these openings to compensate for this leakage. Layering multiple concentric shield shells was highly effective in the perpendicular configuration, but less so for the in-line configuration. Cautious use of high permeability materials such as Mu-metal can greatly increase the shielding performance in some scenarios. In the perpendicular configuration, magnetic shielding was more effective and the impact on the magnet lower compared with the in-line configuration.

  11. Shielding design for positron emission tomography facility

    International Nuclear Information System (INIS)

    Abdallah, I.I.

    2007-01-01

    With the recent advent of readily available tracer isotopes, there has been marked increase in the number of hospital-based and free-standing positron emission tomography (PET) clinics. PET facilities employ relatively large activities of high-energy photon emitting isotopes, which can be dangerous to the health of humans and animals. This coupled with the current dose limits for radiation worker and members of the public can result in shielding requirements. This research contributes to the calculation of the appropriate shielding to keep the level of radiation within an acceptable recommended limit. Two different methods were used including measurements made at selected points of an operating PET facility and computer simulations by using Monte Carlo Transport Code. The measurements mainly concerned the radiation exposure at different points around facility using the survey meter detectors and Thermoluminescent Dosimeters (TLD). Then the set of manual calculation procedures were used to estimate the shielding requirements for a newly built PEF facility. The results from the measurement and the computer simulation were compared to the results obtained from the set manual calculation procedure. In general, the estimated weekly dose at the points of interest is lower than the regulatory limits for the little company of Mary Hospital. Furthermore, the density and the HVL for normal strength concrete and clay bricks are almost similar. In conclusion, PET facilities present somewhat different design requirements and are more likely to require additional radiation shielding. Therefore, existing shields at the little Company of Mary Hospital are in general found to be adequate and satisfactory and additional shielding was found necessary at the new PET facility in the department of Nuclear Medicine of the Dr. George Mukhari Hospital. By use of appropriate design, by implying specific shielding requirements and by maintaining good operating practices, radiation doses to

  12. Scintillation counter, segmented shield

    International Nuclear Information System (INIS)

    Olson, R.E.; Thumim, A.D.

    1975-01-01

    A scintillation counter, particularly for counting gamma ray photons, includes a massive lead radiation shield surrounding a sample-receiving zone. The shield is disassembleable into a plurality of segments to allow facile installation and removal of a photomultiplier tube assembly, the segments being so constructed as to prevent straight-line access of external radiation through the shield into radiation-responsive areas. Provisions are made for accurately aligning the photomultiplier tube with respect to one or more sample-transmitting bores extending through the shield to the sample receiving zone. A sample elevator, used in transporting samples into the zone, is designed to provide a maximum gamma-receiving aspect to maximize the gamma detecting efficiency. (U.S.)

  13. Discontinuous financing based on market values and the value of tax shields

    OpenAIRE

    Arnold, Sven; Lahmann, Alexander; Schwetzler, Bernhard

    2018-01-01

    The tax shield as present value of debt-related tax savings plays an important role in firm valuation. Driving the risk of future debt levels, the firm's strategy to adjust the absolute debt level to future changes of the firm value, labeled as (re-) financing policy, affects the value of tax shields. Standard discounted cash flow (DCF) models offer two simplified (re-) financing policies originally introduced by Modigliani and Miller (MM) as well as Miles and Ezzell (ME). In this paper, we i...

  14. SU-C-BRB-06: Utilizing 3D Scanner and Printer for Dummy Eye-Shield: Artifact-Free CT Images of Tungsten Eye-Shield for Accurate Dose Calculation

    International Nuclear Information System (INIS)

    Park, J; Lee, J; Kim, H; Kim, I; Ye, S

    2015-01-01

    Purpose: To evaluate the effect of a tungsten eye-shield on the dose distribution of a patient. Methods: A 3D scanner was used to extract the dimension and shape of a tungsten eye-shield in the STL format. Scanned data was transferred into a 3D printer. A dummy eye shield was then produced using bio-resin (3D systems, VisiJet M3 Proplast). For a patient with mucinous carcinoma, the planning CT was obtained with the dummy eye-shield placed on the patient’s right eye. Field shaping of 6 MeV was performed using a patient-specific cerrobend block on the 15 x 15 cm 2 applicator. The gantry angle was 330° to cover the planning target volume near by the lens. EGS4/BEAMnrc was commissioned from our measurement data from a Varian 21EX. For the CT-based dose calculation using EGS4/DOSXYZnrc, the CT images were converted to a phantom file through the ctcreate program. The phantom file had the same resolution as the planning CT images. By assigning the CT numbers of the dummy eye-shield region to 17000, the real dose distributions below the tungsten eye-shield were calculated in EGS4/DOSXYZnrc. In the TPS, the CT number of the dummy eye-shield region was assigned to the maximum allowable CT number (3000). Results: As compared to the maximum dose, the MC dose on the right lens or below the eye shield area was less than 2%, while the corresponding RTP calculated dose was an unrealistic value of approximately 50%. Conclusion: Utilizing a 3D scanner and a 3D printer, a dummy eye-shield for electron treatment can be easily produced. The artifact-free CT images were successfully incorporated into the CT-based Monte Carlo simulations. The developed method was useful in predicting the realistic dose distributions around the lens blocked with the tungsten shield

  15. SU-C-BRB-06: Utilizing 3D Scanner and Printer for Dummy Eye-Shield: Artifact-Free CT Images of Tungsten Eye-Shield for Accurate Dose Calculation

    Energy Technology Data Exchange (ETDEWEB)

    Park, J; Lee, J [Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul (Korea, Republic of); Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul (Korea, Republic of); Kim, H [Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul (Korea, Republic of); Interdisciplinary Program in Radiation Applied Life Science, Seoul National University College of Medicine, Seoul (Korea, Republic of); Kim, I [Department of Radiation Oncology, Seoul National University Hospital, Seoul (Korea, Republic of); Interdisciplinary Program in Radiation Applied Life Science, Seoul National University College of Medicine, Seoul (Korea, Republic of); Ye, S [Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul (Korea, Republic of); Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul (Korea, Republic of); Department of Radiation Oncology, Seoul National University Hospital, Seoul (Korea, Republic of); Interdisciplinary Program in Radiation Applied Life Science, Seoul National University College of Medicine, Seoul (Korea, Republic of); Advanced Institutes of Convergence Technology, Seoul National University, Suwon (Korea, Republic of)

    2015-06-15

    Purpose: To evaluate the effect of a tungsten eye-shield on the dose distribution of a patient. Methods: A 3D scanner was used to extract the dimension and shape of a tungsten eye-shield in the STL format. Scanned data was transferred into a 3D printer. A dummy eye shield was then produced using bio-resin (3D systems, VisiJet M3 Proplast). For a patient with mucinous carcinoma, the planning CT was obtained with the dummy eye-shield placed on the patient’s right eye. Field shaping of 6 MeV was performed using a patient-specific cerrobend block on the 15 x 15 cm{sup 2} applicator. The gantry angle was 330° to cover the planning target volume near by the lens. EGS4/BEAMnrc was commissioned from our measurement data from a Varian 21EX. For the CT-based dose calculation using EGS4/DOSXYZnrc, the CT images were converted to a phantom file through the ctcreate program. The phantom file had the same resolution as the planning CT images. By assigning the CT numbers of the dummy eye-shield region to 17000, the real dose distributions below the tungsten eye-shield were calculated in EGS4/DOSXYZnrc. In the TPS, the CT number of the dummy eye-shield region was assigned to the maximum allowable CT number (3000). Results: As compared to the maximum dose, the MC dose on the right lens or below the eye shield area was less than 2%, while the corresponding RTP calculated dose was an unrealistic value of approximately 50%. Conclusion: Utilizing a 3D scanner and a 3D printer, a dummy eye-shield for electron treatment can be easily produced. The artifact-free CT images were successfully incorporated into the CT-based Monte Carlo simulations. The developed method was useful in predicting the realistic dose distributions around the lens blocked with the tungsten shield.

  16. Application of MCNP code in shielding calculation of minitype fast reactor

    International Nuclear Information System (INIS)

    He Keyu; Han Weishi

    2008-01-01

    An accurate shielding calculation model has been set up for the minitype sodium-cooled fast reactor (MFR) based on MCNP code and particular calculation of its primary shielding parameters has been carried out. The results indicate that the photon and neutron flux density of MFR has rapidly fallen to a low-level. The material for the shielding layer outside of main container is primarily of carbon steel, which can be design as a shielding structure satisfying the safety code. The sodium activation in primary circuit is extremely limited and it is simple to shield from. Both the output of helium in reflector and burn up of boron-10 in control rod are very small. These materials can be used for several cycle lives. (authors)

  17. Radiation shielding for fusion reactors

    International Nuclear Information System (INIS)

    Santoro, R.T.

    2000-01-01

    Radiation shielding requirements for fusion reactors present different problems than those for fission reactors and accelerators. Fusion devices, particularly tokamak reactors, are complicated by geometry constraints that complicate disposition of fully effective shielding. This paper reviews some of these shielding issues and suggested solutions for optimizing the machine and biological shielding. Radiation transport calculations are essential for predicting and confirming the nuclear performance of the reactor and, as such, must be an essential part of the reactor design process. Development and optimization of reactor components from the first wall and primary shielding to the penetrations and containment shielding must be carried out in a sensible progression. Initial results from one-dimensional transport calculations are used for scoping studies and are followed by detailed two- and three-dimensional analyses to effectively characterize the overall radiation environment. These detail model calculations are essential for accounting for the radiation leakage through ports and other penetrations in the bulk shield. Careful analysis of component activation and radiation damage is cardinal for defining remote handling requirements, in-situ replacement of components, and personnel access at specific locations inside the reactor containment vessel. (author)

  18. Shielding study of a fusion machine. Elaboration of a global shielding calculation scheme for the Tokamak tore Supra

    International Nuclear Information System (INIS)

    Diop, C.M'B.

    1984-01-01

    This thesis presents a global shielding calculation scheme for neutron and gamma rays arising from the Tokamak TORE SUPRA fusion device, in which a deuterium plasma is used. To study the shield parameters we have elabored a important chaining of neutron and gamma transport codes, TRIPOLI, ANISN, MERCURE 4, allowing to evaluate the radial and skyshine components of the dose rate behind the concrete shield. The study of thermonuclear neutron activation is fundamental to define a tokamak exploitation strategy. For this, two formalisme have been developed. They are based on a modelization of the activation reaction rates according to TRIPOLI, ANISN, and MERCURE 4 codes capabilities. The first one calculates, in one dimensional geometry, the desactivation gamma dose rate inside the vacuum chamber. The second one is a tridimensional model which determines the spatial variation of the gamma dose rate in the machine room. The problem of the existence of runaway electrons and associated secondaries radiations, bremsstrahlung gamma rays particularly, is approched. The results which are presented have contributed to define the parameters of the concrete shield and a strategy for TORE SUPRA Tokamak exploitation [fr

  19. Effect of local sugar and base geometry on {sup 13}C and {sup 15}N magnetic shielding anisotropy in DNA nucleosides

    Energy Technology Data Exchange (ETDEWEB)

    Brumovska, Eva [University of South Bohemia and Biology Centre AS CR v.v.i., Faculty of Science (Czech Republic); Sychrovsky, Vladimir; Vokacova, Zuzana [Institute of Organic Chemistry and Biochemistry, AS CR v.v.i. (Czech Republic); Sponer, Jiri [Institute of Biophysics, AS CR v.v.i. (Czech Republic); Schneider, Bohdan [Biotechnological Institute AS CR (Czech Republic); Trantirek, Lukas [University of South Bohemia and Biology Centre AS CR v.v.i., Faculty of Science (Czech Republic)], E-mail: trant@paru.cas.cz

    2008-11-15

    Density functional theory was employed to study the dependence of {sup 13}C and {sup 15}N magnetic shielding tensors on the glycosidic torsion angle ({chi}) and conformation of the sugar ring in 2'-deoxyadenosine, 2'-deoxyguanosine, 2'-deoxycytidine, and 2'-deoxythymidine. In general, the magnetic shielding of the glycosidic nitrogens and the sugar carbons was found to depend on both the conformation of the sugar ring and {chi}. Our calculations indicate that the magnetic shielding anisotropy of the C6 atom in pyrimidine and the C8 atom in purine bases depends strongly on {chi}. The remaining base carbons were found to be insensitive to both sugar pucker and {chi} re-orientation. These results call into question the underlying assumptions of currently established methods for interpreting residual chemical shift anisotropies and {sup 13}C and {sup 15}N auto- and cross-correlated relaxation rates and highlight possible limitations of DNA applications of these methods.

  20. Communication: The absolute shielding scales of oxygen and sulfur revisited

    Energy Technology Data Exchange (ETDEWEB)

    Komorovsky, Stanislav; Repisky, Michal; Malkin, Elena; Ruud, Kenneth, E-mail: kenneth.ruud@uit.no [Centre for Theoretical and Computational Chemistry, University of Tromsø — The Arctic University of Norway, N-9037 Tromsø (Norway); Gauss, Jürgen [Institut für Physikalische Chemie, Johannes Gutenberg-Universität Mainz, Duesbergweg 10-14, D-55128 Mainz (Germany)

    2015-03-07

    We present an updated semi-experimental absolute shielding scale for the {sup 17}O and {sup 33}S nuclei. These new shielding scales are based on accurate rotational microwave data for the spin–rotation constants of H{sub 2}{sup 17}O [Puzzarini et al., J. Chem. Phys. 131, 234304 (2009)], C{sup 17}O [Cazzoli et al., Phys. Chem. Chem. Phys. 4, 3575 (2002)], and H{sub 2}{sup 33}S [Helgaker et al., J. Chem. Phys. 139, 244308 (2013)] corrected both for vibrational and temperature effects estimated at the CCSD(T) level of theory as well as for the relativistic corrections to the relation between the spin–rotation constant and the absolute shielding constant. Our best estimate for the oxygen shielding constants of H{sub 2}{sup 17}O is 328.4(3) ppm and for C{sup 17}O −59.05(59) ppm. The relativistic correction for the sulfur shielding of H{sub 2}{sup 33}S amounts to 3.3%, and the new sulfur shielding constant for this molecule is 742.9(4.6) ppm.

  1. Parameters calculation of shielding experiment

    International Nuclear Information System (INIS)

    Gavazza, S.

    1986-02-01

    The radiation transport methodology comparing the calculated reactions and dose rates for neutrons and gama-rays, with experimental measurements obtained on iron shield, irradiated in the YAYOI reactor is evaluated. The ENDF/B-IV and VITAMIN-C libraries and the AMPX-II modular system, for cross sections generation collapsed by the ANISN code were used. The transport calculations were made using the DOT 3.5 code, adjusting the boundary iron shield source spectrum to the reactions and dose rates, measured at the beginning of shield. The neutron and gamma ray distributions calculated on the iron shield presented reasonable agreement with experimental measurements. An experimental arrangement using the IEA-R1 reactor to determine a shielding benchmark is proposed. (Author) [pt

  2. PWR upper/lower internals shield

    Energy Technology Data Exchange (ETDEWEB)

    Homyk, W.A. [Indian Point Station, Buchanan, NY (United States)

    1995-03-01

    During refueling of a nuclear power plant, the reactor upper internals must be removed from the reactor vessel to permit transfer of the fuel. The upper internals are stored in the flooded reactor cavity. Refueling personnel working in containment at a number of nuclear stations typically receive radiation exposure from a portion of the highly contaminated upper intervals package which extends above the normal water level of the refueling pool. This same issue exists with reactor lower internals withdrawn for inservice inspection activities. One solution to this problem is to provide adequate shielding of the unimmersed portion. The use of lead sheets or blankets for shielding of the protruding components would be time consuming and require more effort for installation since the shielding mass would need to be transported to a support structure over the refueling pool. A preferable approach is to use the existing shielding mass of the refueling pool water. A method of shielding was devised which would use a vacuum pump to draw refueling pool water into an inverted canister suspended over the upper internals to provide shielding from the normally exposed components. During the Spring 1993 refueling of Indian Point 2 (IP2), a prototype shield device was demonstrated. This shield consists of a cylindrical tank open at the bottom that is suspended over the refueling pool with I-beams. The lower lip of the tank is two feet below normal pool level. After installation, the air width of the natural shielding provided by the existing pool water. This paper describes the design, development, testing and demonstration of the prototype device.

  3. Shielding experiments for accelerator facilities

    Energy Technology Data Exchange (ETDEWEB)

    Nakashima, Hiroshi; Tanaka, Susumu; Sakamoto, Yukio [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment] [and others

    2000-06-01

    A series of shielding experiments was carried out by using AVF cyclotron accelerator of TIARA at JAERI in order to validate shielding design methods for accelerator facilities in intermediate energy region. In this paper neutron transmission experiment through thick shields and radiation streaming experiment through a labyrinth are reported. (author)

  4. Shielding experiments for accelerator facilities

    International Nuclear Information System (INIS)

    Nakashima, Hiroshi; Tanaka, Susumu; Sakamoto, Yukio

    2000-01-01

    A series of shielding experiments was carried out by using AVF cyclotron accelerator of TIARA at JAERI in order to validate shielding design methods for accelerator facilities in intermediate energy region. In this paper neutron transmission experiment through thick shields and radiation streaming experiment through a labyrinth are reported. (author)

  5. Nuclear data for radiation shielding

    International Nuclear Information System (INIS)

    Miyasaka, Shunichi; Takahashi, Hiroshi.

    1976-01-01

    The third shielding expert conference was convened in Paris in Oct. 1975 for exchanging informations about the sensitivity evaluation of nuclear data in shielding calculation and integral bench mark experiment. The requirements about nuclear data presented at present from the field of nuclear design do not reflect sufficiently the requirements of shielding design, therefore it was the object to gather the requirements about nuclear data from the field of shielding. The nuclides used for shielding are numerous, and the nuclear data on these isotopes are required. Some of them cannot be ignored as the source of secondary γ-ray or in view of the radioactivation of materials. The requirements for the nuclear data of neutrons in the field of shielding are those concerning the reaction cross sections producing secondary γ-ray, the reaction cross sections including the production of secondary neutrons, elastic scattering cross sections, and total cross sections. The topics in the Paris conference about neutron shielding data are described, such as the methodology of sensitivity evaluation, the standardization of group constant libraries, the bench mark experiment on iron and sodium, and the cross section of γ-ray production. In the shielding of nuclear fission reactors, the γ-ray production owing to nuclear fission reaction is also important. In (d, t) fusion reactors, high energy neutrons are generated, and high energy γ-ray is emitted through giant E1 resonance. (Kako, I.)

  6. Optimization of multi-layered metallic shield

    International Nuclear Information System (INIS)

    Ben-Dor, G.; Dubinsky, A.; Elperin, T.

    2011-01-01

    Research highlights: → We investigated the problem of optimization of a multi-layered metallic shield. → The maximum ballistic limit velocity is a criterion of optimization. → The sequence of materials and the thicknesses of layers in the shield are varied. → The general problem is reduced to the problem of Geometric Programming. → Analytical solutions are obtained for two- and three-layered shields. - Abstract: We investigate the problem of optimization of multi-layered metallic shield whereby the goal is to determine the sequence of materials and the thicknesses of the layers that provide the maximum ballistic limit velocity of the shield. Optimization is performed under the following constraints: fixed areal density of the shield, the upper bound on the total thickness of the shield and the bounds on the thicknesses of the plates manufactured from every material. The problem is reduced to the problem of Geometric Programming which can be solved numerically using known methods. For the most interesting in practice cases of two-layered and three-layered shields the solution is obtained in the explicit analytical form.

  7. SHIELD verification and validation report

    International Nuclear Information System (INIS)

    Boman, C.

    1992-02-01

    This document outlines the verification and validation effort for the SHIELD, SHLDED, GEDIT, GENPRT, FIPROD, FPCALC, and PROCES modules of the SHIELD system code. Along with its predecessors, SHIELD has been in use at the Savannah River Site (SRS) for more than ten years. During this time the code has been extensively tested and a variety of validation documents have been issued. The primary function of this report is to specify the features and capabilities for which SHIELD is to be considered validated, and to reference the documents that establish the validation

  8. Radiation shield for nuclear reactors

    International Nuclear Information System (INIS)

    Weissenfluh, J.A.

    1978-01-01

    A shield for use with nuclear reactor systems to attenuate radiation resulting from reactor operation is described. The shield comprises a container preferably of a thin, flexible or elastic material, which may be in the form of a bag, a mattress, a toroidal segment or toroid or the like filled with radiation attenuating liuid. Means are provided in the container for filling and draining the container in place. Due to its flexibility, the shield readily conforms to irregularities in surfaces with which it may be in contact in a shielding position

  9. Design of ITER shielding blanket

    International Nuclear Information System (INIS)

    Furuya, Kazuyuki; Sato, Satoshi; Hatano, Toshihisa; Tokami, Ikuhide; Kitamura, Kazunori; Miura, Hidenori; Ito, Yutaka; Kuroda, Toshimasa; Takatsu, Hideyuki

    1997-05-01

    A mechanical configuration of ITER integrated primary first wall/shield blanket module were developed focusing on the welded attachment of its support leg to the back plate. A 100 mm x 150 mm space between the legs of adjacent modules was incorporated for the working space of welding/cutting tools. A concept of coolant branch pipe connection to accommodate deformation due to the leg welding and differential displacement of the module and the manifold/back plate during operation was introduced. Two-dimensional FEM analyses showed that thermal stresses in Cu-alloy (first wall) and stainless steel (first wall coolant tube and shield block) satisfied the stress criteria following ASME code for ITER BPP operation. On the other hand, three-dimensional FEM analyses for overall in-vessel structures exhibited excessive primary stresses in the back plate and its support structure to the vacuum vessel under VDE disruption load and marginal stresses in the support leg of module No.4. Fabrication procedure of the integrated primary first wall/shield blanket module was developed based on single step solid HIP for the joining of Cu-alloy/Cu-alloy, Cu-alloy/stainless steel, and stainless steel/stainless steel. (author)

  10. Hybrid Active-Passive Radiation Shielding System

    Data.gov (United States)

    National Aeronautics and Space Administration — A radiation shielding system is proposed that integrates active magnetic fields with passive shielding materials. The objective is to increase the shielding...

  11. Contaminant deposition building shielding factors for US residential structures.

    Science.gov (United States)

    Dickson, Elijah; Hamby, David; Eckerman, Keith

    2017-10-10

    This paper presents validated building shielding factors designed for contemporary US housing-stock under an idealized, yet realistic, exposure scenario from contaminant deposition on the roof and surrounding surfaces. The building shielding factors are intended for use in emergency planning and level three probabilistic risk assessments for a variety of postulated radiological events in which a realistic assessment is necessary to better understand the potential risks for accident mitigation and emergency response planning. Factors are calculated from detailed computational housing-units models using the general-purpose Monte Carlo N-Particle computational code, MCNP5, and are benchmarked from a series of narrow- and broad-beam measurements analyzing the shielding effectiveness of ten common general-purpose construction materials and ten shielding models representing the primary weather barriers (walls and roofs) of likely US housing-stock. Each model was designed to scale based on common residential construction practices and include, to the extent practical, all structurally significant components important for shielding against ionizing radiation. Calculations were performed for floor-specific locations from contaminant deposition on the roof and surrounding ground as well as for computing a weighted-average representative building shielding factor for single- and multi-story detached homes, both with and without basement as well for single-wide manufactured housing-unit. © 2017 IOP Publishing Ltd.

  12. Contaminant deposition building shielding factors for US residential structures

    International Nuclear Information System (INIS)

    Dickson, E D; Hamby, D M; Eckerman, K F

    2015-01-01

    This paper presents validated building shielding factors designed for contemporary US housing-stock under an idealized, yet realistic, exposure scenario from contaminant deposition on the roof and surrounding surfaces. The building shielding factors are intended for use in emergency planning and level three probabilistic risk assessments for a variety of postulated radiological events in which a realistic assessment is necessary to better understand the potential risks for accident mitigation and emergency response planning. Factors are calculated from detailed computational housing-units models using the general-purpose Monte Carlo N-Particle computational code, MCNP5, and are benchmarked from a series of narrow- and broad-beam measurements analyzing the shielding effectiveness of ten common general-purpose construction materials and ten shielding models representing the primary weather barriers (walls and roofs) of likely US housing-stock. Each model was designed to scale based on common residential construction practices and include, to the extent practical, all structurally significant components important for shielding against ionizing radiation. Calculations were performed for floor-specific locations from contaminant deposition on the roof and surrounding ground as well as for computing a weighted-average representative building shielding factor for single- and multi-story detached homes, both with and without basement as well for single-wide manufactured housing-unit. (paper)

  13. Cloud immersion building shielding factors for US residential structures

    International Nuclear Information System (INIS)

    Dickson, E D; Hamby, D M

    2014-01-01

    This paper presents validated building shielding factors designed for contemporary US housing-stock under an idealized, yet realistic, exposure scenario within a semi-infinite cloud of radioactive material. The building shielding factors are intended for use in emergency planning and level three probabilistic risk assessments for a variety of postulated radiological events in which a realistic assessment is necessary to better understand the potential risks for accident mitigation and emergency response planning. Factors are calculated from detailed computational housing-units models using the general-purpose Monte Carlo N-Particle computational code, MCNP5, and are benchmarked from a series of narrow- and broad-beam measurements analyzing the shielding effectiveness of ten common general-purpose construction materials and ten shielding models representing the primary weather barriers (walls and roofs) of likely US housing-stock. Each model was designed to scale based on common residential construction practices and include, to the extent practical, all structurally significant components important for shielding against ionizing radiation. Calculations were performed for floor-specific locations as well as for computing a weighted-average representative building shielding factor for single- and multi-story detached homes, both with and without basement, as well for single-wide manufactured housing-units. (paper)

  14. RSMASS: A simple model for estimating reactor and shield masses

    International Nuclear Information System (INIS)

    Marshall, A.C.; Aragon, J.; Gallup, D.

    1987-01-01

    A simple mathematical model (RSMASS) has been developed to provide rapid estimates of reactor and shield masses for space-based reactor power systems. Approximations are used rather than correlations or detailed calculations to estimate the reactor fuel mass and the masses of the moderator, structure, reflector, pressure vessel, miscellaneous components, and the reactor shield. The fuel mass is determined either by neutronics limits, thermal/hydraulic limits, or fuel damage limits, whichever yields the largest mass. RSMASS requires the reactor power and energy, 24 reactor parameters, and 20 shield parameters to be specified. This parametric approach should be applicable to a very broad range of reactor types. Reactor and shield masses calculated by RSMASS were found to be in good agreement with the masses obtained from detailed calculations

  15. Shielding experiments in different materials with 252Cf neutron spectra

    International Nuclear Information System (INIS)

    Sathian, Deepa; Marathe, P.K.; Pal, Rupali; Jayalakshmi, V.; Chourasiya, G.; Mayya, Y.S.

    2008-01-01

    Adequate shielding for neutron sources can be determined using analytical method or by actually measuring the attenuation for the target configuration. This paper describes the measurement of Half Value Thickness (HVT), Tenth Value Thickness (TVT), Σ values for four different shielding materials, using a standard 252 Cf neutron source and comparing with the values calculated using an empirical relationship. BF 3 based REM-counter is used for measurement of neutron dose equivalent, against different thickness of the shielding material. The experimental HVT and S values are in good agreement with the calculated values. From this study, it is concluded that, among the four materials studied, high density polyethylene (HDPE) is best suitable for the shielding of a 252 Cf neutron source. (author)

  16. Method for calculating required shielding in medical x-ray rooms

    International Nuclear Information System (INIS)

    Karppinen, J.

    1997-10-01

    The new annual radiation dose limits - 20 mSv (previously 50 mSv) for radiation workers and 1 mSv (previously 5 mSv) for other persons - implies that the adequacy of existing radiation shielding must be re-evaluated. In principle, one could assume that the thicknesses of old radiation shields should be increased by about one or two half-value layers in order to comply with the new dose limits. However, the assumptions made in the earlier shielding calculations are highly conservative; the required shielding was often determined by applying the maximum high-voltage of the x-ray tube for the whole workload. A more realistic calculation shows that increased shielding is typically not necessary if more practical x-ray tube voltages are used in the evaluation. We have developed a PC-based calculation method for calculating the x-ray shielding which is more realistic than the highly conservative method formerly used. The method may be used to evaluate an existing shield for compliance with new regulations. As examples of these calculations, typical x-ray rooms are considered. The lead and concrete thickness requirements as a function of x-ray tube voltage and workload are also given in tables. (author)

  17. Handout on shielding calculation

    International Nuclear Information System (INIS)

    Heilbron Filho, P.F.L.

    1991-01-01

    In order to avoid the difficulties of the radioprotection supervisors in the tasks related to shielding calculations, is presented in this paper the basic concepts of shielding theory. It also includes exercises and examples. (author)

  18. Pretinning Nickel-Plated Wire Shields

    Science.gov (United States)

    Igawa, J. A.

    1985-01-01

    Nickel-plated copper shielding for wires pretinned for subsequent soldering with help of activated rosin flux. Shield cut at point 0.25 to 0.375 in. (6 to 10 mm) from cut end of outer jacket. Loosened end of shield straightened and pulled toward cut end. Insulation of inner wires kept intact during pretinning.

  19. Radiation Shielding Materials and Containers Incorporating Same

    Energy Technology Data Exchange (ETDEWEB)

    Mirsky, Steven M.; Krill, Stephen J.; and Murray, Alexander P.

    2005-11-01

    An improved radiation shielding material and storage systems for radioactive materials incorporating the same. The PYRolytic Uranium Compound (''PYRUC'') shielding material is preferably formed by heat and/or pressure treatment of a precursor material comprising microspheres of a uranium compound, such as uranium dioxide or uranium carbide, and a suitable binder. The PYRUC shielding material provides improved radiation shielding, thermal characteristic, cost and ease of use in comparison with other shielding materials. The shielding material can be used to form containment systems, container vessels, shielding structures, and containment storage areas, all of which can be used to house radioactive waste. The preferred shielding system is in the form of a container for storage, transportation, and disposal of radioactive waste. In addition, improved methods for preparing uranium dioxide and uranium carbide microspheres for use in the radiation shielding materials are also provided.

  20. Measuring space radiation shielding effectiveness

    Directory of Open Access Journals (Sweden)

    Bahadori Amir

    2017-01-01

    Full Text Available Passive radiation shielding is one strategy to mitigate the problem of space radiation exposure. While space vehicles are constructed largely of aluminum, polyethylene has been demonstrated to have superior shielding characteristics for both galactic cosmic rays and solar particle events due to the high hydrogen content. A method to calculate the shielding effectiveness of a material relative to reference material from Bragg peak measurements performed using energetic heavy charged particles is described. Using accelerated alpha particles at the National Aeronautics and Space Administration Space Radiation Laboratory at Brookhaven National Laboratory, the method is applied to sample tiles from the Heat Melt Compactor, which were created by melting material from a simulated astronaut waste stream, consisting of materials such as trash and unconsumed food. The shielding effectiveness calculated from measurements of the Heat Melt Compactor sample tiles is about 10% less than the shielding effectiveness of polyethylene. Shielding material produced from the astronaut waste stream in the form of Heat Melt Compactor tiles is therefore found to be an attractive solution for protection against space radiation.

  1. Measuring space radiation shielding effectiveness

    Science.gov (United States)

    Bahadori, Amir; Semones, Edward; Ewert, Michael; Broyan, James; Walker, Steven

    2017-09-01

    Passive radiation shielding is one strategy to mitigate the problem of space radiation exposure. While space vehicles are constructed largely of aluminum, polyethylene has been demonstrated to have superior shielding characteristics for both galactic cosmic rays and solar particle events due to the high hydrogen content. A method to calculate the shielding effectiveness of a material relative to reference material from Bragg peak measurements performed using energetic heavy charged particles is described. Using accelerated alpha particles at the National Aeronautics and Space Administration Space Radiation Laboratory at Brookhaven National Laboratory, the method is applied to sample tiles from the Heat Melt Compactor, which were created by melting material from a simulated astronaut waste stream, consisting of materials such as trash and unconsumed food. The shielding effectiveness calculated from measurements of the Heat Melt Compactor sample tiles is about 10% less than the shielding effectiveness of polyethylene. Shielding material produced from the astronaut waste stream in the form of Heat Melt Compactor tiles is therefore found to be an attractive solution for protection against space radiation.

  2. Evaluation of usability of the shielding effect for thyroid shield for peripheral dose during whole brain radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Myung Sic; Park, Ju Kyeong; Lee, Seung Hun; Kim, Yang Su; Lee, Sun Young; Cha, Seok Yong [Dept. of Radiation Oncology, Chonbuk National University Hospital, Jeonju (Korea, Republic of)

    2014-12-15

    To reduce the radiation dose to the thyroid that is affected to scattered radiation, the shield was used. And we evaluated the shielding effect for the thyroid during whole brain radiation therapy. To measure the dose of the thyroid, 300cGy were delivered to the phantom using a linear accelerator(Clinac iX VARIAN, USA.)in the way of the 6MV X-ray in bilateral. To measure the entrance surface dose of the thyroid, five glass dosimeters were placed in the 10th slice's surface of the phantom with a 1.5 cm interval. The average values were calculated by measured values in five times each, using bismuth shield, 0.5 mmPb shield, self-made 1.0 mmPb shield and unshield. In the same location, to measure the depth dose of the thyroid, five glass dosimeters were placed in the 10th slice by 2.5 cm depth of the phantom with a 1.5 cm interval. The average values were calculated by measured values in five times each, using bismuth shield, 0.5 mmPb shield, self-made 1.0 mmPb shield and unshield. Entrance surface dose of the thyroid were respectively 44.89 mGy at the unshield, 36.03 mGy at the bismuth shield, 31.03 mGy at the 0.5 mmPb shield and 23.21 mGy at a self-made 1.0 mmPb shield. In addition, the depth dose of the thyroid were respectively 36.10 mGy at the unshield, 34.52 mGy at the bismuth shield, 32.28 mGy at the 0.5 mmPb shield and 25.50 mGy at a self-made 1.0 mmPb shield. The thyroid was affected by the secondary scattering dose and leakage dose outside of the radiation field during whole brain radiation therapy. When using a shield in the thyroid, the depth dose of thyroid showed 11-30% reduction effect and the surface dose of thyroid showed 20-48% reduction effect. Therefore, by using the thyroid shield, it is considered to effectively protect the thyroid and can perform the treatment.

  3. A model-based approach of scatter dose contributions and efficiency of apron shielding for radiation protection in CT.

    Science.gov (United States)

    Weber, N; Monnin, P; Elandoy, C; Ding, S

    2015-12-01

    Given the contribution of scattered radiations to patient dose in CT, apron shielding is often used for radiation protection. In this study the efficiency of apron was assessed with a model-based approach of the contributions of the four scatter sources in CT, i.e. external scattered radiations from the tube and table, internal scatter from the patient and backscatter from the shielding. For this purpose, CTDI phantoms filled with thermoluminescent dosimeters were scanned without apron, and then with an apron at 0, 2.5 and 5 cm from the primary field. Scatter from the tube was measured separately in air. The scatter contributions were separated and mathematically modelled. The protective efficiency of the apron was low, only 1.5% in scatter dose reduction on average. The apron at 0 cm from the beam lowered the dose by 7.5% at the phantom bottom but increased the dose by 2% at the top (backscatter) and did not affect the centre. When the apron was placed at 2.5 or 5 cm, the results were intermediate to the one obtained with the shielding at 0 cm and without shielding. The apron effectiveness is finally limited to the small fraction of external scattered radiation. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  4. A Simple Accounting-based Valuation Model for the Debt Tax Shield

    Directory of Open Access Journals (Sweden)

    Andreas Scholze

    2010-05-01

    Full Text Available This paper describes a simple way to integrate the debt tax shield into an accounting-based valuation model. The market value of equity is determined by forecasting residual operating income, which is calculated by charging operating income for the operating assets at a required return that accounts for the tax benefit that comes from borrowing to raise cash for the operations. The model assumes that the firm maintains a deterministic financial leverage ratio, which tends to converge quickly to typical steady-state levels over time. From a practical point of view, this characteristic is of particular help, because it allows a continuing value calculation at the end of a short forecast period.

  5. Novel shielding materials for space and air travel

    International Nuclear Information System (INIS)

    Vana, N.; Hajek, M.; Berger, T.; Fugger, M.; Hofmann, P.

    2006-01-01

    The reduction of dose onboard spacecraft and aircraft by appropriate shielding measures plays an essential role in the future development of space exploration and air travel. The design of novel shielding strategies and materials may involve hydrogenous composites, as it is well known that liquid hydrogen is most effective in attenuating charged particle radiation. As precursor for a later flight experiment, the shielding properties of newly developed hydrogen-rich polymers and rare earth-doped high-density rubber were tested in various ground-based neutron and heavy ion fields and compared with aluminium and polyethylene as reference materials. Absorbed dose, average linear energy transfer and gamma-equivalent neutron absorbed dose were determined by means of LiF:Mg,Ti thermoluminescence dosemeters and CR-39 plastic nuclear track detectors. First results for samples of equal aerial density indicate that selected hydrogen-rich plastics and rare-earth-doped rubber may be more effective in attenuating cosmic rays by up to 10% compared with conventional aluminium shielding. The appropriate adaptation of shielding thicknesses may thus allow reducing the biologically relevant dose. Owing to the lower density of the plastic composites, mass savings shall result in a significant reduction of launch costs. The experiment was flown as part of the European Space Agency's Biopan-5 mission in May 2005. (authors)

  6. Shielding technology for high energy radiation production facility

    International Nuclear Information System (INIS)

    Lee, Byung Chul; Kim, Heon Il

    2004-06-01

    In order to develop shielding technology for high energy radiation production facility, references and data for high energy neutron shielding are searched and collected, and calculations to obtain the characteristics of neutron shield materials are performed. For the evaluation of characteristics of neutron shield material, it is chosen not only general shield materials such as concrete, polyethylene, etc., but also KAERI developed neutron shields of High Density PolyEthylene (HDPE) mixed with boron compound (B 2 O 3 , H 2 BO 3 , Borax). Neutron attenuation coefficients for these materials are obtained for later use in shielding design. The effect of source shape and source angular distribution on the shielding characteristics for several shield materials is examined. This effect can contribute to create shielding concept in case of no detail source information. It is also evaluated the effect of the arrangement of shield materials using current shield materials. With these results, conceptual shielding design for PET cyclotron is performed. The shielding composite using HDPE and concrete is selected to meet the target dose rate outside the composite, and the dose evaluation is performed by configuring the facility room conceptually. From the result, the proper shield configuration for this PET cyclotron is proposed

  7. A Modeling of BWR-MOX assemblies based on the characteristics method combined with advanced self-shielding models

    International Nuclear Information System (INIS)

    Le Tellier, R.; Hebert, A.; Le Tellier, R.; Santamarina, A.; Litaize, O.

    2008-01-01

    Calculations based on the characteristics method and different self-shielding models are presented for 9 x 9 boiling water reactor (BWR) assemblies fully loaded with mixed-oxide (MOX) fuel. The geometry of these assemblies was recovered from the BASALA experimental program. We have focused our study on three configurations simulating the different voiding conditions that an assembly can undergo in a BWR pressure vessel. A parametric study was carried out with respect to the spatial discretization, the tracking parameters, and the anisotropy order. Comparisons with Monte Carlo calculations in terms of k eff , radiative capture, and fission rates were performed to validate the computational tools. The results are in good agreement between the stochastic and deterministic approaches. The mutual self-shielding model recently introduced within the framework of the Ribon extending self-shielding method appears to be useful for this type of assemblies. Indeed, in the calculation of these MOX benchmarks, the overlapping of resonances, especially between 238 U and 240 Pu, plays an important role due to the spectral strengthening of the flux as the voiding percentage is increased. The method of characteristics is shown to be adequate to perform accurate calculations handling a fine spatial discretization. (authors)

  8. Hybrid Magnetic Shielding

    Science.gov (United States)

    Royal, Kevin; Crawford, Christopher; Mullins, Andrew; Porter, Greg; Blanton, Hunter; Johnstone, Connor; Kistler, Ben; Olivera, Daniela

    2017-09-01

    The search for the electric dipole moment of the neutron requires the ambient magnetic field to be on the pT scale which is accomplished with large magnetic shielding rooms. These rooms are fitted with large mu-metal sheets to allow for passive cancellation of background magnetic fields. Active shielding technology cannot uniformly cancel background magnetic fields. These issues can be remedied by combining the methods into a hybrid system. The design used is composed of panels that have an active layer of cancellation between two sheets of mu-metal. The panels form a cube and draw in magnetic fields perpendicular to the surface which can then be reduced using active shielding. This work is supported by the Department of Energy under Contract DE-SC0008107.

  9. Modular reactor head shielding system

    International Nuclear Information System (INIS)

    Jacobson, E. B.

    1985-01-01

    An improved modular reactor head shielding system is provided that includes a frame which is removably assembled on a reactor head such that no structural or mechanical alteration of the head is required. The shielding system also includes hanging assemblies to mount flexible shielding pads on trolleys which can be moved along the frame. The assemblies allow individual pivoting movement of the pads. The pivoting movement along with the movement allowed by the trolleys provides ease of access to any point on the reactor head. The assemblies also facilitate safe and efficient mounting of the pads directly to and from storage containers such that workers have additional shielding throughout virtually the entire installation and removal process. The flexible shielding pads are designed to interleave with one another when assembled around the reactor head for substantially improved containment of radiation leakage

  10. Mechanical shielded hot cell

    International Nuclear Information System (INIS)

    Higgy, H.R.; Abdel-Rassoul, A.A.

    1983-01-01

    A plan to erect a mechanical shielded hot cell in the process hall of the Radiochemical Laboratory at Inchas is described. The hot cell is designed for safe handling of spent fuel bundles, from the Inchas reactor, and for dismantling and cutting the fuel rods in preparation for subsequent treatment. The biological shielding allows for the safe handling of a total radioactivity level up to 10,000 MeV-Ci. The hot cell consists of an α-tight stainless-steel box, connected to a γ-shielded SAS, through an air-lock containing a movable carriage. The α-box is tightly connected with six dry-storage cavities for adequate storage of the spent fuel bundles. Both the α-box, with the dry-storage cavities, and the SAS are surrounded by 200-mm thick biological lead shielding. The α-box is equipped with two master-slave manipulators, a lead-glass window, a monorail crane and Padirac and Minirag systems. The SAS is equipped with a lead-glass window, tong manipulator, a shielded pit and a mechanism for the entry of the spent fuel bundle. The hot cell is served by adequate ventilation and monitoring systems. (author)

  11. Radiation shielding

    International Nuclear Information System (INIS)

    Aitken, D.

    1979-01-01

    Shields for equipment in which ionising radiation is associated with high electrical gradients, for example X-ray tubes and particle accelerators, incorporate a radiation-absorbing metal, as such or as a compound, and are electrically non-conducting and can be placed in the high electrical gradient region of the equipment. Substances disclosed include dispersions of lead, tungsten, uranium or oxides of these in acrylics polyesters, PVC, ABS, polyamides, PTFE, epoxy resins, glass or ceramics. The material used may constitute an evacuable enclosure of the equipment or may be an external shield thereof. (U.K.)

  12. BMFO-PVDF electrospun fiber based tunable metamaterial structures for electromagnetic interference shielding in microwave frequency region

    Science.gov (United States)

    Revathi, Venkatachalam; Dinesh Kumar, Sakthivel; Subramanian, Venkatachalam; Chellamuthu, Muthamizhchelvan

    2015-11-01

    Metamaterial structures are artificial structures that are useful in controlling the flow of electromagnetic radiation. In this paper, composite fibers of sub-micron thickness of barium substituted magnesium ferrite (Ba0.2Mg0.8Fe2O4) - polyvinylidene fluoride obtained by electrospinning is used as a substrate to design electromagnetic interference shielding structures. While electrospinning improves the ferroelectric properties of the polyvinylidene fluoride, the presence of barium magnesium ferrite modifies the magnetic property of the composite fiber. The dielectric and magnetic properties at microwave frequency measured using microwave cavity perturbation technique are used to design the reflection as well as absorption based tunable metamaterial structures for electromagnetic interference shielding in microwave frequency region. For one of the structures, the simulation indicates that single negative metamaterial structure becomes a double negative metamaterial under the external magnetic field.

  13. Le craton ouest-africain et le bouclier guyanais: un seul craton au Protérozoïque inférieur?

    Science.gov (United States)

    Caen-Vachette, Michelle

    Geochronological and paleomagnetism data for southern West African craton and Guyana shield in South America, are concordant and suggest the existence of a large unit grouping them during Archean and Lower Proterozoic times. The paleomagnetism data allow to put on a single line, the Zednes (Mauritania), Sassandra (Ivory Coast) and Guri (Venezuela) fault zones, the mylonites of which were dated 1670 Ma. This age reflects the end of the eburnean-transamazonian shearing tectonic, which affected the large West Africa-Guyana unit. This line separates the western Archean domain from the eastern lower Proterozoic one; thence it is possible to correlate the Sasca (Ivory Coast) and Pastora (Venezuela) areas. Archean relics have been found in mobile pan-african-bresiliano zones which surround the Precambrian cratons; this fact suggests the existence of still more extended Archean craton than defined above.

  14. Computed tomography shielding methods: a literature review.

    Science.gov (United States)

    Curtis, Jessica Ryann

    2010-01-01

    To investigate available shielding methods in an effort to further awareness and understanding of existing preventive measures related to patient exposure in computed tomography (CT) scanning. Searches were conducted to locate literature discussing the effectiveness of commercially available shields. Literature containing information regarding breast, gonad, eye and thyroid shielding was identified. Because of rapidly advancing technology, the selection of articles was limited to those published within the past 5 years. The selected studies were examined using the following topics as guidelines: the effectiveness of the shield (percentage of dose reduction), the shield's effect on image quality, arguments for or against its use (including practicality) and overall recommendation for its use in clinical practice. Only a limited number of studies have been performed on the use of shields for the eyes, thyroid and gonads, but the evidence shows an overall benefit to their use. Breast shielding has been the most studied shielding method, with consistent agreement throughout the literature on its effectiveness at reducing radiation dose. The effect of shielding on image quality was not remarkable in a majority of studies. Although it is noted that more studies need to be conducted regarding the impact on image quality, the currently published literature stresses the importance of shielding in reducing dose. Commercially available shields for the breast, thyroid, eyes and gonads should be implemented in clinical practice. Further research is needed to ascertain the prevalence of shielding in the clinical setting.

  15. Radiation shielding cloth

    International Nuclear Information System (INIS)

    Ijiri, Yasuo; Fujinuma, Tadashi; Tamura, Shoji.

    1989-01-01

    Radiation shielding cloth having radiation shielding layers comprising a composition of inorganic powder of high specific gravity and rubber are excellentin flexibility and comfortable to put on. However, since they are heavy in the weight, operators are tired upon putting them for a long time. In view of the above, the radiation ray shielding layers are prepared by calendering sheets obtained by preliminary molding of the composition to set the variation of the thickness within a range of +15% to -0% of prescribed thickness. Since the composition of inorganic powder at high specific gravity and rubber used for radiation ray shielding comprises a great amount of inorganic powder at high specific gravity blended therein, it is generally poor in fabricability. Therefor, it is difficult to attain fine control for the sheet thickness by merely molding a composition block at once. Then, the composition is at first preliminarily molded into a sheet-like shape which is somewhat thickener than the final thickness and then finished by calendering, by which the thickness can be reduced in average as compared with conventional products while keeping the prescribed thickness and reducing the weight reduce by so much. (N.H.)

  16. Radiation shielding glass

    International Nuclear Information System (INIS)

    Kido, Kazuhiro; Ueda, Hajime.

    1997-01-01

    It was found that a glass composition comprising, as essential ingredients, SiO 2 , PbO, Gd 2 O 3 and alkali metal oxides can provide a shielding performance against electromagnetic waves, charged particles and neutrons. The present invention provides radiation shielding glass containing at least from 16 to 46wt% of SiO 2 , from 47 to 75wt% of PbO, from 1 to 10wt% of Gd 2 O 3 , from 0 to 3wt% of Li 2 O, from 0 to 7wt% of Na 2 O, from 0 to 7wt% of K 2 O provided that Li 2 O + Na 2 O + K 2 O is from 1 to 10wt%, B 2 O 3 is from 0 to 10wt%, CeO 2 is from 0 to 3wt%, As 2 O 3 is from 0 to 1wt% and Sb 2 O 3 is from 0 to 1wt%. Since the glass can shield electromagnetic waves, charged particles and neutrons simultaneously, radiation shielding windows can be designed and manufactured at a reduced thickness and by less constitutional numbers in a circumstance where they are present altogether. (T.M.)

  17. Dynamic Open-Rotor Composite Shield Impact Test Report

    Science.gov (United States)

    Seng, Silvia; Frankenberger, Charles; Ruggeri, Charles R.; Revilock, Duane M.; Pereira, J. Michael; Carney, Kelly S.; Emmerling, William C.

    2015-01-01

    The Federal Aviation Administration (FAA) is working with the European Aviation Safety Agency to determine the certification base for proposed new engines that would not have a containment structure on large commercial aircraft. Equivalent safety to the current fleet is desired by the regulators, which means that loss of a single fan blade will not cause hazard to the aircraft. NASA Glenn and Naval Air Warfare Center (NAWC) China Lake collaborated with the FAA Aircraft Catastrophic Failure Prevention Program to design and test a shield that would protect the aircraft passengers and critical systems from a released blade that could impact the fuselage. This report documents the live-fire test from a full-scale rig at NAWC China Lake. NASA provided manpower and photogrammetry expertise to document the impact and damage to the shields. The test was successful: the blade was stopped from penetrating the shield, which validates the design analysis method and the parameters used in the analysis. Additional work is required to implement the shielding into the aircraft.

  18. Shielding modification design of the N.S. Mutsu

    International Nuclear Information System (INIS)

    Yamaji, A.; Miyakoshi, J.; Kageyama, T.; Futamura, Y.

    1983-01-01

    Shielding modification design of the N.S. Mutsu was performed for reducing the radiation doses outside the primary and the secondary shields by providing shields for neutrons streaming through the air gap between the pressure vessel and the primary shield. This was accomplished by replacing parts of the shields and adding new shields in the upper and lower sections of both primary and secondary shields, and also replacing the thermal insulator in the gap. The shielding design calculations were made using one- and two-dimensional discrete ordinates codes and also a point kernel code. Special attention was paid to the calculations of, (1) the neutrons streaming through the gap between the pressure vessel and the primary shield, (2) the radiations transmitted through the radial shield of the core in the primary shield, (3) the radiations transmitted through the upper and lower sections of the secondary shield, and (4) the dose rate equivalent in the accommodation area. Their calculational accuracies were estimated by analyzing various experiments. To support the modification, a variety of experiments and tests were carried out, which were material tests, cooling test of the primary shield, mechanical strength test of the double bottom, trial fabrication tests of new shields, performance degradation test of heavy concrete and duct streaming experiment in the secondary shield. (author)

  19. Radiation shielding curtain

    International Nuclear Information System (INIS)

    Winkler, N.T.

    1976-01-01

    A radiation shield is described in the form of a stranded curtain made up of bead-chains whose material and geometry are selected to produce a cross-sectional density that is the equivalent of 0.25 mm or more of lead and which curtain may be mounted on various radiological devices to shield against scattered radiation while offering a minimum of obstruction to the radiologist

  20. Method for limiting movement of a thermal shield for a nuclear reactor, and thermal shield displacement limiter therefor

    International Nuclear Information System (INIS)

    Meuschke, R.E.; Boyd, C.H.

    1989-01-01

    This patent describes a method of limiting the movement of a thermal shield of a nuclear reactor. It comprises: machining at least four (4) pockets in upper portions of a thermal shield circumferentially about a core barrel of a nuclear reactor to receive key-wave inserts; tapping bolt holes in the pockets of the thermal shield to receive bolts; positioning key-wave inserts into the pockets of the thermal shield to be bolted in place with the bolt holes; machining dowel holes at least partially through the positioned key-way inserts and the thermal shield to receive dowel pins; positioning dowel pins in the dowel holes in the key-way insert and thermal shield to tangentially restrain movement of the thermal shield relative to the core barrel; sliding limiter keys into the key-way inserts and bolting the limiter keys to the core barrel to tangentially restrain movement of the thermal shield relative and the core barrel while allowing radial and axial movement of the thermal shield relative to the core barrel; machining dowel holes through the limiter key and at least partially through the core barrel to receive dowel pins; positioning dowel pins in the dowel holes in the limiter key and core barrel to restrain tangential movement of the thermal shield relative to the core barrel of the nuclear reactor

  1. Penetration shielding applications of CYLSEC

    International Nuclear Information System (INIS)

    Dexheimer, D.T.; Hathaway, J.M.

    1985-01-01

    Evaluation of penetration and discontinuity shielding is necessary to meet 10CFR20 regulations for ensuring personnel exposures are as low as reasonably achievable (ALARA). Historically, those shielding evaluations have been done to some degree on all projects. However, many early plants used conservative methods due to lack of an economical computer code, resulting in costly penetration shielding programs. With the increased industry interest in cost effectively reducing personnel exposures to meet ALARA regulations and with the development of the CYLSEC gamma transport computer code at Bechtel, a comprehensive effort was initiated to reduce penetration and discontinuity shielding but still provide a prudent degree of protection for plant personnel from radiation streaming. This effort was more comprehensive than previous programs due to advances in shielding analysis technology and increased interest in controlling project costs while maintaining personnel exposures ALARA. Methodology and resulting cost savings are discussed

  2. Welding shield for coupling heaters

    Science.gov (United States)

    Menotti, James Louis

    2010-03-09

    Systems for coupling end portions of two elongated heater portions and methods of using such systems to treat a subsurface formation are described herein. A system may include a holding system configured to hold end portions of the two elongated heater portions so that the end portions are abutted together or located near each other; a shield for enclosing the end portions, and one or more inert gas inlets configured to provide at least one inert gas to flush the system with inert gas during welding of the end portions. The shield may be configured to inhibit oxidation during welding that joins the end portions together. The shield may include a hinged door that, when closed, is configured to at least partially isolate the interior of the shield from the atmosphere. The hinged door, when open, is configured to allow access to the interior of the shield.

  3. Shield calculations, optimization vs. paradigm

    International Nuclear Information System (INIS)

    Cornejo D, N.; Hernandez S, A.; Martinez G, A.

    2006-01-01

    Many shieldings have been designed under the criteria of 'Maximum dose rates of project'. It has created the paradigm of those 'low dose rates', for the one which not few specialists would consider unacceptable levels of dose rate superior to the units of μSv.h -1 , independently of the exposure times. At the present time numerous shieldings are being designed considering dose restrictions in real times of exposure. After these new shieldings, the dose rates could be notably superior to those after traditional shieldings, without it implies inadequate designs or constructive errors. In the work significant differences in levels of dose rates and thickness of shieldings estimated by both methods for some typical facilities. It was concluded that the use of real times of exposure is more adequate for the optimization of the Radiological Protection, although this method demands bigger care in its application. (Author)

  4. Several problems in accelerator shielding study

    International Nuclear Information System (INIS)

    Nakamura, Takashi; Hirayama, Hideo; Ban, Shuichi.

    1980-01-01

    Recently, the utilization of accelerators has increased rapidly, and the increase of accelerating energy and beam intensity is also remarkable. The studies on accelerator shielding have become important, because the amount of radiation emitted from accelerators increased, the regulation of the dose of environmental radiation was tightened, and the cost of constructing shielding rose. As the plans of constructing large accelerators have been made successively, the survey on the present state and the problems of the studies on accelerator shielding was carried out. Accelerators are classified into electron accelerators and proton accelerators in view of the studies on shielding. In order to start the studies on accelerator shielding, first, the preparation of the cross section data is indispensable. The cross sections for generating Bremsstrahlung, photonuclear reactions generating neutrons, generation of neutrons by hadrons, nuclear reaction of neutrons and generation of gamma-ray by hadrons are described. The generation of neutrons and gamma-ray as the problems of thick targets is explained. The shielding problems are complex and diversified, but in this paper, the studies on the shielding, by which basic data are obtainable, are taken up, such as beam damping and side wall shielding. As for residual radioactivity, main nuclides and the difference of residual radioactivity according to substances have been studied. (J.P.N.)

  5. Shielding concerns at a spallation source

    International Nuclear Information System (INIS)

    Russell, G.J.; Robinson, H.; Legate, G.L.; Woods, R.

    1989-01-01

    Neutrons produced by 800-MeV proton reactions at the Los Alamos Neutron Scattering Center spallation neutron source cause a variety of challenging shielding problems. We identify several characteristics distinctly different from reactor shielding and compute the dose attenuation through an infinite slab/shield composed of iron (100 cm) and borated polyethylene (15 cm). Our calculations show that (for an incident spallation spectrum characteristic of neutrons leaking from a tungsten target at 90/degree/) the dose through the shield is a complex mixture of neutrons and gamma rays. High-energy (> 20 MeV) neutron production from the target is ≅5% of the total, yet causes ≅68% of the dose at the shield surface. Primary low-energy (< 20 MeV) neutrons from the target contribute negligibly (≅0.5%) to the dose at the shield surface yet cause gamma rays, which contribute ≅31% to the total dose at the shield surface. Low-energy neutrons from spallation reactions behave similarly to neutrons with a fission spectrum distribution. 6 refs., 8 figs., 1 tab

  6. Highly heat removing radiation shielding material

    International Nuclear Information System (INIS)

    Asano, Norio; Hozumi, Masahiro.

    1990-01-01

    Organic materials, inorganic materials or metals having excellent radiation shielding performance are impregnated into expanded metal materials, such as Al, Cu or Mg, having high heat conductivity. Further, the porosity of the expanded metals and combination of the expanded metals and the materials to be impregnated are changed depending on the purpose. Further, a plurality of shielding materials are impregnated into the expanded metal of the same kind, to constitute shielding materials. In such shielding materials, impregnated materials provide shielding performance against radiation rays such as neutrons and gamma rays, the expanded metals provide heat removing performance respectively and they act as shielding materials having heat removing performance as a whole. Accordingly, problems of non-informity and discontinuity in the prior art can be dissolved be provide materials having flexibility in view of fabrication work. (T.M.)

  7. Gonadal Shielding in Radiography: A Best Practice?

    Science.gov (United States)

    Fauber, Terri L

    2016-11-01

    To investigate radiation dose to phantom testes with and without shielding. A male anthropomorphic pelvis phantom was imaged with thermoluminescent dosimeters (TLDs) placed in the right and left detector holes corresponding to the testes. Ten exposures were made of the pelvis with and without shielding. The exposed TLDs were packaged securely and mailed to the University of Wisconsin Calibration Laboratory for reading and analysis. A t test was calculated for the 2 exposure groups (no shield and shielded) and found to be significant, F = 8.306, P shield was used during pelvic imaging. Using a flat contact shield during imaging of the adult male pelvis significantly reduces radiation dose to the testes. Regardless of the contradictions in the literature on gonadal shielding, the routine practice of shielding adult male gonads during radiographic imaging of the pelvis is a best practice. © 2016 American Society of Radiologic Technologists.

  8. Selective shielding device for scintiphotography

    International Nuclear Information System (INIS)

    Harper, J.W.; Kay, T.D.

    1976-01-01

    A selective shielding device to be used in combination with a scintillation camera is described. The shielding device is a substantially oval-shaped configuration removably secured to the scintillation camera. As a result of this combination scanning of preselected areas of a patient can be rapidly and accurately performed without the requirement of mounting any type of shielding paraphernalia on the patient. 1 claim, 2 drawing figures

  9. Radiation shielding material

    International Nuclear Information System (INIS)

    Matsumoto, Akio; Isobe, Eiji.

    1976-01-01

    Purpose: To increase the shielding capacity of the radiation shielding material having an abundant flexibility. Constitution: A mat consisting of a lead or lead alloy fibrous material is covered with a cloth, and the two are made integral by sewing in a kilted fashion by using a yarn. Thereafter, the system is covered with a gas-tight film or sheet. The shielding material obtained in this way has, in addition to the above merits, advantages in that (1) it is free from restoration due to elasticity so that it can readily seal contaminants, (2) it can be used in a state consisting of a number of overlapped layers, (3) it fits the shoulder well and is readily portable and (4) it permits attachment of fasteners or the like. (Ikeda, J.)

  10. Simplified shielding calculation system for high-intensity proton accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Masumura, Tomomi; Nakashima, Hiroshi; Nakane, Yoshihiro; Sasamoto, Nobuo [Center for Neutron Science, Tokai Research Establishment, Japan Atomic Energy Research Institute, Tokai, Ibaraki (Japan)

    2000-06-01

    A simplified shielding calculation system is developed for applying conceptual shielding design of facilities in the joint project for high-intensity proton accelerators. The system is composed of neutron transmission calculation part for bulk shielding using simplified formulas: Moyer model and Tesch's formula, and neutron skyshine calculation part using an empirical formula: Stapleton's formula. The system is made with the Microsoft Excel software for user's convenience. This report provides a manual for the system as well as calculation conditions used in the calculation such as Moyer model's parameters. In this report preliminary results based on data at December 8, 1999, are also shown as an example. (author)

  11. Radiation shielding in dental radiography

    International Nuclear Information System (INIS)

    Stenstroem, B.; Rehnmark-Larsson, S.; Julin, P.; Richter, S.

    1983-01-01

    The protective effect in the thyroid region from different types of radiation shieldings at intraoral radiography has been studied as well as the reduction of the absorbed dose to the sternal and the gonadal regions. The shieldings tested were five different types of leaded aprons, of which three had an attached leaded collar and the other two were used in combination with separate soft leaded collars. Furthermore one of the soft leaded collars and an unflexible horizontal leaded shield were tested separately. Two dental x-ray machines of 60 and 65 kVp with rectangular and circular tube collimators were used. The exposure time corresponded to speed group E film. The absorbed doses were measured with two ionization chambers. No significant difference in the protective effect in the thyroid gland could be found between the different types of radiation shieldings. There was a dose reduction by approximately a factor of 2 to the thyroid region down to 0.08 mGy per full survey using parallelling technique, and below 0.001 mGy per single bitewing exposure. The shieldings reduced the thyroid dose using bisecting-angle technique by a factor of 5 down to 0.15 mGy per full survey (20 exposures). In the sternal region the combinations of apron and collar reduced the absorbed dose from a full survey to below 2 μGy compared with 18 μGy (parallelling) and 31 μGy (biscting-angle) without any shielding. With the horizontal leaded shield a reduction by a factor of 6 was obtained but no significant sternal dose reduction could be detected from the soft collar alone. The gonadal dose could be reduced by a factor of 10 with the horizontal leaded shield, parallelling technique and circular collimator. Using leaded aprons the gonadal dose was approximately one per cent of the dose without any shielding, i.e. below 0.01 μGy per single intraoral exposure. (Authors)

  12. A New Infrared Desert Dust Index over French Guyana Rain forest: First results

    Science.gov (United States)

    Molinie, J.; Barnacin, E.; Henry, J. L.; Gobinddass, M. L.; Panechou-Pulcherie, K.; Feuillard, T.; Nagau, J.

    2017-12-01

    Recently a NASA researcher showed the role of desert dust contribution for the Amazonian rain forest. In another hand, desert dust impact population health when PM 10 level reached values around and upper the PM 10 threshold of the 50 µg m-3, established by the World Health Organization (WHO). Infrared Desert Dust Index (IDDI) developed by Legrand with Meteosat infrared images, allow the following of desert dust plumes over semi-arid land. In French Guiana the WHO threshold is currently overpass in measurements done by ORA air quality network, in the two main towns located close to the coast. For inland population, it is very difficult to have continuous dust measures due to the low infrastructure supplies. We need to develop a tools in order to follow the crossing of desert dust over the French Guyana rain forest, from the coast to inland villages. Following the IDDI concept and comparing with VIIRS AOT EDR result over the same area, a modified IDDI for Amazonian region (IDDI_A) has been proposed to identify the dusty pixels over the forest. Despite of high cloud presence, a good correlation between AOT EDR and IDDI_A was obtained. The IDDI_A calculation has been applied over French Guiana area for different PM 10 level at Cayenne, a town along the coast.

  13. SPADA: a project to study the effectiveness of shielding materials in space

    International Nuclear Information System (INIS)

    Pugliese, M.; Casolino, M.; Cerciello, V.

    2008-01-01

    The SPADA (SPAce Dosimetry for Astronauts) project is a part of an extensive teamwork that aims to optimize shielding solutions against space radiation. Shielding is indeed all irreplaceable tool to reduce, exposure of crews of future Moon and Mars missions. We concentrated our studies on two flexible materials, Kevlar (R) and Nextel (R), because of their ability to protect space infrastructure from micro meteoroids measured radiation hardness of these shielding materials and compared to polyethylene, generally acknowledged as the most effective space radiation shield with practical applications in spacecraft. Both flight test (on the International Space Station and on the Russian FOTON M3 rocket), with passive dosimeters and accelerator-based experiments have been performed. Accelerator tests using high-energy Fe ions have demonstrated that Kevlar is almost as effective as polyethylene in shielding heavy ions, while Nextel is a poor shield against, high-charge and -energy particles. Preliminary results from spaceflight, however, show that for the radiation environment ill low-Earth orbit. dominated by trapped protons, thin shields of Kevlar and Nextel provide limited reduction.

  14. Hematological and Biochemistry Profile and Risk Factors Associated with Pulmonary Tuberculosis Patients in Guyana

    Directory of Open Access Journals (Sweden)

    Rajini Kurup

    2016-01-01

    Full Text Available Objective. To evaluate the hematological and biochemistry profile of patients with or without HIV-TB at the Georgetown Chest Clinic, Guyana. Methods. An observational, laboratory based study was designed to assess the relationship of PTB and HIV with patients routine biochemical and hematological values. The study was conducted during the period January 2013 to December 2014; a total sample size of 316 patients was enrolled following exclusion and inclusion criteria. Results. Mean age of study population was 40.1 ± 13.8 (95% CI 38.6–41.7 and most were between 40 and 49 age group (27.8%, 95% CI 23.2–33.0. More males were in the study 74.4% (95% CI 69.3–78.8 than females 81% (95% CI 21.1–30.7. 30% (95% CI 25.3–35.3 had a sputum smear grade of 3+ and 62.5% (95% CI 47.0–75.7 showed a CD4 count <200. The study demonstrated significantly low hemoglobin (Hb 91.7% (95% CI 78.2–97.1, low WBC 27.8% (95% CI 15.8–44.0, high indirect bilirubin 7.4% (95% CI 2.1–23.3, ALT 41.8% (95% CI 28.4–56.7, and AST 72.2% (95% CI 57.3–83.3 among TB-HIV patients. Homelessness RR (relative risk 2.2 (95% CI 0.48–12.3, smoking RR 1.09 (95% CI 1.01–1.19, and gender (male RR 1.2 (95% CI 0.61–2.26 were main associated risk factors. Conclusions. There is slight variation among PTB and PTB-HIV coinfected patients in some hematological and biochemistry parameters.

  15. Shielding property of bismuth glass based on MCNP 5 and WINXCOM simulated calculation

    International Nuclear Information System (INIS)

    Zhang Zhicheng; Zhang Jinzhao; Liu Ze; Lu Chunhai; Chen Min

    2013-01-01

    Background: Currently, lead glass is widely used as observation window, while lead is toxic heavy metal. Purpose: Non-toxic materials and their shielding effects are researched in order to find a new material to replace lead containing material. Methods: The mass attenuation coefficients of bismuth silicate glass were investigated with gamma-ray's energy at 0.662 MeV, 1.17 MeV and 1.33 MeV, respectively, by MCNP 5 (Monte Carlo) and WINXCOM program, and compared with those of the lead glass. Results: With attenuation factor K, shielding and mechanical properties taken into consideration bismuth glass containing 50% bismuth oxide might be selected as the right material. Dose rate distributions of water phantom were calculated with 2-cm and 10-cm thick glass, respectively, irradiated by 137 Cs and 60 Co in turn. Conclusion: Results show that the bismuth glass may replace lead glass for radiation shielding with appropriate energy. (authors)

  16. Shielding effectiveness of superconductive particles in plastics

    International Nuclear Information System (INIS)

    Pienkowski, T.; Kincaid, J.; Lanagan, M.T.; Poeppel, R.B.; Dusek, J.T.; Shi, D.; Goretta, K.C.

    1988-09-01

    The ability to cool superconductors with liquid nitrogen instead of liquid helium has opened the door to a wide range of research. The well known Meissner effect, which states superconductors are perfectly diamagnetic, suggests shielding applications. One of the drawbacks to the new ceramic superconductors is the brittleness of the finished material. Because of this drawback, any application which required flexibility (e.g., wire and cable) would be impractical. Therefore, this paper presents the results of a preliminary investigation into the shielding effectiveness of YBa 2 Cu 3 O/sub 7-x/ both as a composite and as a monolithic material. Shielding effectiveness was measured using two separate test methods. One tested the magnetic (near field) shielding, and the other tested the electromagnetic (far field) shielding. No shielding was seen in the near field measurements on the composite samples, and only one heavily loaded sample showed some shielding in the far field. The monolithic samples showed a large amount of magnetic shielding. 5 refs., 5 figs

  17. Terrestrial mammal assemblages in protected and human impacted areas in Northern Brazilian Amazonia

    Directory of Open Access Journals (Sweden)

    Rodolfo Burgos de Luna

    2017-10-01

    Full Text Available Mammal communities in the vicinity of human settlements are often subject to subsistence hunting and retaliatory killings. We used fourteen digital camera traps equipped with infrared triggers to sample the medium-sized and large mammal communities for ca. 34 (±1.64 days per site. Diversity was measured as both Shannon entropy and Fager´s number of moves (NMS, and dominance was quantified using the Berger-Parker index. We used Kruskall-Wallis tests to investigate if there were statistically significant differences in richness, diversity and dominance among the sites. At an overall sampling effort of 1,946 trap days we recorded 216 independent observations of a total of 20 species belonging to 17 genera and 15 families. Richness and diversity appeared to be determined by forest structure, since, independent of the level of human impact, the richest areas were those closest to the ombrophilous forests of southern Guyana shield, closest to central Amazonia, whereas the poorest were at those sites closest to the vegetation mosaics of central Guyana shield. The disappearance of Tayassu pecari from the impacted areas as well as higher relative abundances in the protected areas, albeit not significant, foresees a possible bleak future for the mammalian assemblages in the near future.

  18. Thermal testing of solid neutron shielding materials

    International Nuclear Information System (INIS)

    Boonstra, R.H.

    1993-01-01

    In May-June 1989 the first series of full-scale thermal tests was performed on three shielding materials: Bisco Products NS-4-FR, and Reactor Experiments RX-201 and RX-207. The tests are described in Thermal Testing of Solid Neutron Shielding Materials, GA-A19897, R.H. Boonstra, General Atomics (1990), and demonstrated the acceptability of these materials in a thermal accident. Subsequent design changes to the cask rendered these materials unattractive in terms of weight or adequate service temperature margin. For the second test series a material specification was developed for a polypropylene based neutron shield with a softening point of at least 280degF. Table 1 lists the neutron shield materials tested. The Envirotech and Bisco materials are not polypropylene, but were tested as potential backup materials in the event that a satisfactory polypropylene could not be found. The Bisco modified NS-4 and Reactor Experiments HMPP are both acceptable materials from a thermal accident standpoint for use in the shipping cask. Tests of the Kobe PP-R01 and Envirotech HDPE were stopped for safety reasons, due to inability to deal with the heavy smoke, before completion of the 30-minute heating phase. However these materials may prove satisfactory if they could undergo the complete heating. (J.P.N.)

  19. Shielding and grounding in large detectors

    International Nuclear Information System (INIS)

    Radeka, V.

    1998-09-01

    Prevention of electromagnetic interference (EMI), or ''noise pickup,'' is an important design aspect in large detectors in accelerator environments. Shielding effectiveness as a function of shield thickness and conductivity vs the type and frequency of the interference field is described. Noise induced in transmission lines by ground loop driven currents in the shield is evaluated and the importance of low shield resistance is emphasized. Some measures for prevention of ground loops and isolation of detector-readout systems are discussed

  20. Tax Shield, Insolvenz und Zinsschranke

    OpenAIRE

    Arnold, Sven; Lahmann, Alexander; Schwetzler, Bernhard

    2010-01-01

    Dieser Beitrag analysiert den Wertbeitrag fremdfinanzierungsbedingter Steuervorteile (Tax Shield) unter realistischen Bedingungen (keine Negativsteuer; mögliche Insolvenz) für unterschiedliche Finanzierungspolitiken. Zusätzlich wird der Effekt der sogenannten Zinsschranke auf den Wert des Tax Shield ermittelt. Die Bewertung des Tax Shield mit und ohne Zinsschranke findet im einperiodigen Fall auf der Basis von Optionspreismodellen und im mehrperiodigen Fall auf der Basis von Monte Carlo Simul...

  1. Measuring space radiation shielding effectiveness

    OpenAIRE

    Bahadori Amir; Semones Edward; Ewert Michael; Broyan James; Walker Steven

    2017-01-01

    Passive radiation shielding is one strategy to mitigate the problem of space radiation exposure. While space vehicles are constructed largely of aluminum, polyethylene has been demonstrated to have superior shielding characteristics for both galactic cosmic rays and solar particle events due to the high hydrogen content. A method to calculate the shielding effectiveness of a material relative to reference material from Bragg peak measurements performed using energetic heavy charged particles ...

  2. Shield wall evaluation of hot cell facility for advanced spent fuel conditioning process

    International Nuclear Information System (INIS)

    Cho, I. J.; Kuk, D. H.; Ko, J. H.; Jung, W. M.; Yoo, G. S.; Lee, E. P.; Park, S. W.

    2002-01-01

    The future hot cell is located in the Irradiated Material Experiment Facility (IMEF) at the Korea Atomic Energy Research Institute (KAERI). It is β-γ type hot cell that was constructed on the base floor in IMEF building for irradiated material testing. And this hot cell will be used for carrying out the Advanced spent fuel Conditioning Process (ACP). The radiation shielding capability of hot cell should be sufficient to meet the radiation dose requirements in the related regulations. Because the radioactive sources of ACP are expected to be higher than radioactive sources of IMEF design criteria, the future hot cell in current status is unsatisfactory to hot test of ACP. So the shielding analysis of the future hot cell is performed to evaluate shielding ability of concrete shield wall. The shielding analysis included (a) identification of ACP source term; (b) photon source spectrum; (c) shielding analysis by QADS and MCNP-4C; and (d) enhancement of concrete shield wall. In this research, dose rates are obtained according to ACP source, geometry and hot cell shield wall thickness. And the evaluation and reinforcement thickness of the shield wall about future hot cell are concluded

  3. Development of highly effective neutron shielding material made of phenol-novolac type epoxy resin

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Soo Haeng; Jeong, Myeong Soo; Hong, Sun Seok; Lee, Won Kyoung; Kim, Ik Soo; Shin, Young Joon; Do, Jae Bum; Ro, Seung Gy; Oh, Seok Jin

    1998-06-01

    Because the exposure to radiation in the nuclear facilities can be fatal to human, it is important to reduce the radiation dose level to a tolerable level. The purpose of this study is to develop highly effective neutron shielding materials for the shipping and storage cask of radioactive materials or in the nuclear/radiation facilities. On this study, we developed epoxy resin based neutron shielding materials and their various material properties, including neutron shielding ability, fire resistance, combustion characteristics, radiation resistance, thermal and mechanical properties were evaluated experimentally. Especially we developed phenol-novolac type epoxy resin based neutron shielding materials and their characteristics were also evaluated. (author). 22 refs., 11 tabs., 21 figs

  4. Shielding tests for a new ship for the transport of spent nuclear fuels

    International Nuclear Information System (INIS)

    Ito, D.; Kitano, T.; Akiyama, H.; Ueki, K.; Sanui, T.

    1998-01-01

    a new ship for the transport of spent nuclear fuels which uses serpentine concrete as its major shielding material has been constructed. The shielding calculations are based on DOT3.5 code (CCC-276) and the DLC23). Experiments with Cf-252 and Co-60 sources were carried out to confirm the validity of this method of calculating the shielding effectiveness of serpentine concrete. In these experiments, neutron and gamma-ray dose equivalent rates were measured in various arrangements to simulate the shielding structures of the ship, the calculations for each arrangement were performed by this shielding calculation method. For both neutron and gamma-rays, the calculation results agreed with the experiments very well, confirming that this calculation method used in the ship's shielding design is valid. Two kinds of on-board gamma-ray shielding tests were performed to confirm the ship's actual shielding effectiveness. In one kind of test, gamma-ray dose equivalent rates were measured for each shielding wall using Co-60 sources. In the other kind of test, gamma-ray dose equivalent rates in the ship's accommodation area were measured when a strong Co-60 source was placed in a loaded shipping cask's position. In both gamma-ray shielding tests all measured dose equivalent rates were less than the calculated values, confirming that the ship's actual shielding is sufficient to meet safety requirements. (authors)

  5. Gonad shielding in computerized tomography

    International Nuclear Information System (INIS)

    Rockstroh, G.

    1984-01-01

    The reduction of gonadal dose by shielding of the gonads was investigated for a Somatom 2 using an anthropomorphic phantom. For small distances from the slice examined the gonadal dose results from intracorporal secondary radiation and is only insignificantly reduced by shielding. For greater distances shielding is relatively more effective, the gonadal dose however is small because of the approximately exponential decay. Shielding of the gonads therefore does not seem adequate for the reduction of gonadal dose. From dose measurements in cylinder phantoms of several diameters it appears that no different results would be obtained for children and young adults. An effective reduction of gonadal dose is only possible with lead capsules for males. (author)

  6. Flux trapping and shielding in irreversible superconductors

    International Nuclear Information System (INIS)

    Frankel, D.J.

    1978-05-01

    Flux trappings and shielding experiments were carried out on Pb, Nb, Pb-Bi, Nb-Sn, and Nb-Ti samples of various shapes. Movable Hall probes were used to measure fields near or inside the samples as a function of position and of applied field. The trapping of transverse multipole magnetic fields in tubular samples was accomplished by cooling the samples in an applied field and then smoothly reducing the applied field to zero. Transverse quadrupole and sextupole fields with gradients of over 2000 G/cm were trapped with typical fidelity to the original impressed field of a few percent. Transverse dipole fields of up to 17 kG were also trapped with similar fidelity. Shielding experiments were carried out by cooling the samples in zero field and then gradually applying an external field. Flux trapping and shielding abilities were found to be limited by two factors, the pinning strength of the material, and the susceptibility of a sample to flux jumping. The trapping and shielding behavior of flat disk samples in axial fields and thin-walled tubular samples in transverse fields was modeled. The models, which were based on the concept of the critical state, allowed a connection to be made between the pinning strength and critical current level, and the flux trapping and shielding abilities. Adiabatic and dynamic stability theories are discussed and applied to the materials tested. Good qualitative, but limited quantitative agreement was obtained between the predictions of the theoretical stability criteria and the observed flux jumping behavior

  7. A phantom-based evaluation of three commercially available patient organ shields for computed tomography X-ray examinations in diagnostic radiology

    International Nuclear Information System (INIS)

    Huggett, J.; Mukonoweshuro, W.; Loader, R.

    2013-01-01

    Three commercially available in-plane patient organ shields (barium eye, bismuth eye and bismuth breast) for computed tomography (CT) examinations were evaluated to determine their effectiveness for dose reduction. Absorbed doses were measured using metal oxide semiconductor field effect transistor dosemeters fastened to a Kyoto CT Torso phantom. Resultant images were visually compared with those minus shielding by an experienced radiologist. Approximate dose reductions of 21, 38 and 50 % were achieved by the barium eye, bismuth eye and bismuth breast shields, respectively, at a cost of increased image noise and streak artefacts. Shielded images produced varied levels of image artefact, particularly those resulting from the eye shields. Measured dose reductions were not consistent with the potential dose savings stated by the manufacturers of the shields. When evaluating the breast shield, similar dose reduction was achieved without shield-induced artefact by simply reducing the X-ray tube current. (authors)

  8. Dosimetry and shielding

    International Nuclear Information System (INIS)

    Farinelli, U.

    1977-01-01

    Today, reactor dosimetry and shielding have wide areas of overlap as concerns both problems and methods. Increased interchange of results and know-how would benefit both. The areas of common interest include calculational methods, sensitivity studies, theoretical and experimental benchmarks, cross sections and other nuclear data, multigroup libraries and procedures for their adjustment, experimental techniques and damage functions. This paper reviews the state-of-the-art and the latest development in each of these areas as far as shielding is concerned, and suggests a number of interactions that could be profitable for reactor dosimetry. Among them, re-evaluation of the potentialities of calculational methods (in view of the recent developments) in predicting radiation environments of interest; the application of sensitivity analysis to dosimetry problems; a common effort in the field of theoretical benchmarks; the use of the shielding one-material propagation experiments as reference spectra for detector cross sections; common standardization of the detector nuclear data used in both fields; the setting up of a common (or compatible) multigroup structure and library applicable to shielding, dosimetry and core physics; the exchange of information and experience in the fields of cross section errors, correlations and adjustment; and the intercomparison of experimental techniques

  9. Radiation shielding analysis

    International Nuclear Information System (INIS)

    Moon, S.H.; Ha, C.W.; Kwon, S.K.; Lee, J.K.; Choi, H.S.

    1982-01-01

    The theoretical bases of radiation streaming analysis in power reactors, such as ducts or reactor cavity, have been investigated. Discrete ordinates-Monte Carlo or Monte Carlo-Monte Carlo coupling techniques are suggested for the streaming analysis of ducts or reactor cavity. Single albedo scattering approximation code (SINALB) has been developed for simple and quick estimation of gamma-ray ceiling scattering, where the ceiling is assumed to be semi-infinite medium. This code has been employed to calculate the gamma-ray ceiling scattering effects in the laboratory containing a Co-60 source. The SINALB is applicable to gamma-ray scattering, only where the ceiling is thicker than Σsup(-1) and the height is at least twice higher than the shield wall. This code can be used for the purpose of preliminary radiation shield design. The MORSE code has been improved to analyze the gamma-ray scattering problem with on approximation method in respect to the random walk and estimation processes. This improved MORSE code has been employed to the gamma-ray ceiling scattering problem. The results of the improved MORSE calculation are in good agreement with the SINALB and standard MORSE. (Author)

  10. Neutron shielding and its impact on the ITER machine design

    International Nuclear Information System (INIS)

    Daenner, W.; El Guebaly, L.; Sawan, M.; Gohar, Y.; Maki, K.; Rado, V.; Schchipakin, O.; Zimin, S.

    1991-01-01

    This paper describes the efforts made in the frame of the ITER project to analyze the shielding of the superconducting magnets. First, the radiation limits to be achieved are specified as well as the neutron source in terms of wall loading on the first wall of the machine. Then the general shield concept is explained, including the most essential details of the various shield components. A brief section is devoted to the calculational tools, the data base, and the safety factors to be applied to the results obtained. The neutronics models of four different configurations are summarized as they were used to study the most critical parts of the machine. This section is followed by a presentation of the most important results from one-, two- and three-dimensional calculations. They are given for both the reference design and an improved one in which the critical regions are reinforced with respect to their shielding capability. It is concluded that the ITER shield layout just marginally meets the stated limits provided that some tungsten is included in the critical regions. A slight revision of the overall machine dimensions with the aim to achieve a less complex shield and a higher margin with respect to the limits is, however, seen the better solution. (orig.)

  11. Improving the shielding effectiveness of a board-level shield by bonding it with the waveguide-below-cutoff principle

    OpenAIRE

    Degraeve, Andy; Pissoort, Davy; Armstrong, Keith

    2015-01-01

    This paper discusses the shielding performance or shielding effectiveness of a board-level shield in function of its bonding method. Improved shielding performance at board-level in order to harden integrated circuits against unintentional and intentional electromagnetic interference, and this under harsh environmental conditions, is getting more and more important to achieve the desired levels of functional performance and operational reliability despite an ever more aggressive electromagnet...

  12. [Leptospirosis in French Guiana and the Guiana shield: Current knowledge in 2016].

    Science.gov (United States)

    Epelboin, L; Bourhy, P; Le Turnier, P; Schaub, R; Mosnier, E; Berlioz-Arthaud, A; Reynaud, Y; Nacher, M; De Thoisy, B; Carles, G; Richard-Hansen, C; Demar, M; Picardeau, M; Djossou, F

    2017-08-01

    Leptospirosis is a cosmopolitan zoonosis caused by bacteria of the genus Leptospira. Whether the distribution is worldwide, the hot and humid climate of the tropics is particularly conducive to its expansion. In most French overseas departments and territories, leptospirosis is considered as a public health problem. In French Guiana, a French department located in the northeastern part of the Amazon rainforest, it is supposed to be rare. The objective of this review was to make an inventory of the knowledge on human and animal leptospirosis in French Guiana and neighboring countries. A comprehensive search was conducted through the indexed and informal medical literature in English, French, Spanish and Portuguese. Thus, respectively ten and four publications were identified on human and animal leptospirosis in French Guiana, published between 1940 and 1995 in the form of case reports or case series. The publications concerning this disease in the other countries of the Guiana Shield, eastern Venezuela, Guyana, Suriname, and Brazilian state of Amapá, also scarce or nonexistent. However recent data from the French National Centre of leptospirosis showed a recent and sudden increase in the number of cases in the department, probably partly due to the development of diagnostic tools such as Elisa IgM serology. It is likely that leptospirosis is a neglected disease in the region, due to the lack of diagnostic tools readily available, the lack of knowledge of the local clinicians on this disease and the existence of many other pathogens with similar clinical presentation such as malaria, arboviruses and Q fever and Amazonian toxoplasmosis. The establishment of more large-scale studies on animal and human leptospirosis is necessary and urgent to know the true burden of this disease in our region.

  13. Radiation protection/shield design

    International Nuclear Information System (INIS)

    Disney, R.K.

    1977-01-01

    Radiation protection/shielding design of a nuclear facility requires a coordinated effort of many engineering disciplines to meet the requirements imposed by regulations. In the following discussion, the system approach to Clinch River Breeder Reactor Plant (CRBRP) radiation protection will be described, and the program developed to implement this approach will be defined. In addition, the principal shielding design problems of LMFBR nuclear reactor systems will be discussed in realtion to LWR nuclear reactor system shielding designs. The methodology used to analyze these problems in the U.S. LMFBR program, the resultant design solutions, and the experimental verification of these designs and/or methods will be discussed. (orig.) [de

  14. Shielding design of ITER pressure suppression system

    International Nuclear Information System (INIS)

    Yamauchi, Michinori; Sato, Satoshi; Nishitani, Takeo; Kawasaki, Hiromitsu

    2006-01-01

    The duct shield from streaming D-T neutrons has been designed for the ITER pressure suppression system. Streaming calculations are performed with the DUCT-III code for the region from the inlet of the pressure relief line to the rupture disk. Next, the neutron permeation through the shield is studied by Monte Carlo calculations with the MCNP code. It is found that 0.15 m thick iron shield is enough to suppress the permeating component from the outside. In addition, it is suggested that the volume of the shield can be reduced by about 30% if the optimized iron shield structure having localized thickness across intense permeation paths is employed to shield the pressure suppression line. (T.I.)

  15. Protein structure refinement using a quantum mechanics-based chemical shielding predictor.

    Science.gov (United States)

    Bratholm, Lars A; Jensen, Jan H

    2017-03-01

    The accurate prediction of protein chemical shifts using a quantum mechanics (QM)-based method has been the subject of intense research for more than 20 years but so far empirical methods for chemical shift prediction have proven more accurate. In this paper we show that a QM-based predictor of a protein backbone and CB chemical shifts (ProCS15, PeerJ , 2016, 3, e1344) is of comparable accuracy to empirical chemical shift predictors after chemical shift-based structural refinement that removes small structural errors. We present a method by which quantum chemistry based predictions of isotropic chemical shielding values (ProCS15) can be used to refine protein structures using Markov Chain Monte Carlo (MCMC) simulations, relating the chemical shielding values to the experimental chemical shifts probabilistically. Two kinds of MCMC structural refinement simulations were performed using force field geometry optimized X-ray structures as starting points: simulated annealing of the starting structure and constant temperature MCMC simulation followed by simulated annealing of a representative ensemble structure. Annealing of the CHARMM structure changes the CA-RMSD by an average of 0.4 Å but lowers the chemical shift RMSD by 1.0 and 0.7 ppm for CA and N. Conformational averaging has a relatively small effect (0.1-0.2 ppm) on the overall agreement with carbon chemical shifts but lowers the error for nitrogen chemical shifts by 0.4 ppm. If an amino acid specific offset is included the ProCS15 predicted chemical shifts have RMSD values relative to experiments that are comparable to popular empirical chemical shift predictors. The annealed representative ensemble structures differ in CA-RMSD relative to the initial structures by an average of 2.0 Å, with >2.0 Å difference for six proteins. In four of the cases, the largest structural differences arise in structurally flexible regions of the protein as determined by NMR, and in the remaining two cases, the large structural

  16. Superconducting magnetic shields production. Realisation d'ecrans magnetiques supraconducteurs

    Energy Technology Data Exchange (ETDEWEB)

    Lainee, F; Kormann, R [Thomson-CSF, Domaine de Corbeville, 91 - Orsay (FR); Lainee, F [Ecole des Mines de Paris, 91 - Evry (FR)

    1992-02-01

    Low fields and low frequency shielding properties of YBCO magnetic shields are measured at 77 K. They compare favourably with shielding properties of mumetal shields. Therefore high-T{sub c} superconducting magnetic shields can already be used to shield small volumes. The case of magnetic shields for large volumes is also discussed. 3 refs; 6 figs; 4 tabs.

  17. Problems of the power plant shield optimization

    International Nuclear Information System (INIS)

    Abagyan, A.A.; Dubinin, A.A.; Zhuravlev, V.I.; Kurachenko, Yu.A.; Petrov, Eh.E.

    1981-01-01

    General approaches to the solution of problems on the nuclear power plant radiation shield optimization are considered. The requirements to the shield parameters are formulated in a form of restrictions on a number of functionals, determined by the solution of γ quantum and neutron transport equations or dimensional and weight characteristics of shield components. Functional determined by weight-dimensional parameters (shield cost, mass and thickness) and functionals, determined by radiation fields (equivalent dose rate, produced by neutrons and γ quanta, activation functional, radiation functional, heat flux, integral heat flux in a particular part of the shield volume, total energy flux through a particular shield surface are considered. The following methods of numerical solution of simplified optimization problems are discussed: semiempirical methods using radiation transport physical leaks, numerical solution of approximate transport equations, numerical solution of transport equations for the simplest configurations making possible to decrease essentially a number of variables in the problem. The conclusion is drawn that the attained level of investigations on the problem of nuclear power plant shield optimization gives the possibility to pass on at present to the solution of problems with a more detailed account of the real shield operating conditions (shield temperature field account, its strength and other characteristics) [ru

  18. Neutron shielding for a 252 Cf source

    International Nuclear Information System (INIS)

    Vega C, H.R.; Manzanares A, E.; Hernandez D, V.M.; Eduardo Gallego, Alfredo Lorente

    2006-01-01

    To determine the neutron shielding features of water-extended polyester a Monte Carlo study was carried out. Materials with low atomic number are predominantly used for neutron shielding because these materials effectively attenuate neutrons, mainly through inelastic collisions and absorption reactions. During the selection of materials to design a neutron shield, prompt gamma production as well as radionuclide production induced by neutron activation must be considered. In this investigation the Monte Carlo method was used to evaluate the performance of a water-extended polyester shield designed for the transportation, storage, and use of a 252 Cf isotopic neutron source. During calculations a detailed model for the 252 Cf and the shield was utilized. To compare the shielding features of water extended polyester, the calculations were also made for the bare 252 Cf in vacuum, air and the shield filled with water. For all cases the calculated neutron spectra was utilized to determine the ambient equivalent neutron dose at four sites around the shielding. In the case of water extended polyester and water shielding the calculations were extended to include the prompt gamma rays produced during neutron interactions, with this information the Kerma in air was calculated at the same locations where the ambient equivalent neutron dose was determined. (Author)

  19. Methods for calculating radiation attenuation in shields

    Energy Technology Data Exchange (ETDEWEB)

    Butler, J; Bueneman, D; Etemad, A; Lafore, P; Moncassoli, A M; Penkuhn, H; Shindo, M; Stoces, B

    1964-10-01

    In recent years the development of high-speed digital computers of large capacity has revolutionized the field of reactor shield design. For compact special-purpose reactor shields, Monte-Carlo codes in two- and three dimensional geometries are now available for the proper treatment of both the neutron and gamma- ray problems. Furthermore, techniques are being developed for the theoretical optimization of minimum-weight shield configurations for this type of reactor system. In the design of land-based power reactors, on the other hand, there is a strong incentive to reduce the capital cost of the plant, and economic considerations are also relevant to reactors designed for merchant ship propulsion. In this context simple methods are needed which are economic in their data input and computing time requirements and which, at the same time, are sufficiently accurate for design work. In general the computing time required for Monte-Carlo calculations in complex geometry is excessive for routine design calculations and the capacity of the present codes is inadequate for the proper treatment of large reactor shield systems in three dimensions. In these circumstances a wide range of simpler techniques are currently being employed for design calculations. The methods of calculation for neutrons in reactor shields fall naturally into four categories: Multigroup diffusion theory; Multigroup diffusion with removal sources; Transport codes; and Monte Carlo methods. In spite of the numerous Monte- Carlo techniques which are available for penetration and back scattering, serious problems are still encountered in practice with the scattering of gamma rays from walls of buildings which contain critical facilities and also concrete-lined discharge shafts containing irradiated fuel elements. The considerable volume of data in the unclassified literature on the solution of problems of this type in civil defence work appears not to have been evaluated for reactor shield design. In

  20. Radiation shielding application of lead glass

    International Nuclear Information System (INIS)

    Nathuram, R.

    2017-01-01

    Nuclear medicine and radiotherapy centers equipped with high intensity X-ray or teletherapy sources use lead glasses as viewing windows to protect personal from radiation exposure. Lead is the main component of glass which is responsible for shielding against photons. It is therefore essential to check the shielding efficiency before they are put in use. This can be done by studying photon transmission through the lead glasses. The study of photon transmission in shielding materials has been an important subject in medical physics and is potential useful in the development of radiation shielding materials

  1. Core test reactor shield cooling system analysis

    International Nuclear Information System (INIS)

    Larson, E.M.; Elliott, R.D.

    1971-01-01

    System requirements for cooling the shield within the vacuum vessel for the core test reactor are analyzed. The total heat to be removed by the coolant system is less than 22,700 Btu/hr, with an additional 4600 Btu/hr to be removed by the 2-inch thick steel plate below the shield. The maximum temperature of the concrete in the shield can be kept below 200 0 F if the shield plug walls are kept below 160 0 F. The walls of the two ''donut'' shaped shield segments, which are cooled by the water from the shield and vessel cooling system, should operate below 95 0 F. The walls of the center plug, which are cooled with nitrogen, should operate below 100 0 F. (U.S.)

  2. Practical radiation shielding for biomedical research

    International Nuclear Information System (INIS)

    Klein, R.C.; Reginatto, M.; Party, E.; Gershey, E.L.

    1990-01-01

    This paper reports on calculations which exist for estimating shielding required for radioactivity; however, they are often not applicable for the radionuclides and activities common in biomedical research. A variety of commercially available Lucite shields are being marketed to the biomedical community. Their advertisements may lead laboratory workers to expect better radiation protection than these shields can provide or to assume erroneously that very weak beta emitters require extensive shielding. The authors have conducted a series of shielding experiments designed to simulate exposures from the amounts of 32 P, 51 Cr and 125 I typically used in biomedical laboratories. For most routine work, ≥0.64 cm of Lucite covered with various thicknesses of lead will reduce whole-body occupational exposure rates of < 1mR/hr at the point of contact

  3. BRH Gonad Shielding Program: where it has led

    International Nuclear Information System (INIS)

    Arcarese, J.S.

    1975-01-01

    Some topics discussed are: Bureau of Radiological Health guidelines; types of gonad shields; specific area shielding; gonad shielding guidelines; and publication of pamphlet on types of shields and circumstances under which they should be used

  4. Evaluating shielding effectiveness for reducing space radiation cancer risks

    International Nuclear Information System (INIS)

    Cucinotta, Francis A.; Kim, Myung-Hee Y.; Ren, Lei

    2006-01-01

    We discuss calculations of probability distribution functions (PDF) representing uncertainties in projecting fatal cancer risk from galactic cosmic rays (GCR) and solar particle events (SPE). The PDFs are used in significance tests for evaluating the effectiveness of potential radiation shielding approaches. Uncertainties in risk coefficients determined from epidemiology data, dose and dose-rate reduction factors, quality factors, and physics models of radiation environments are considered in models of cancer risk PDFs. Competing mortality risks and functional correlations in radiation quality factor uncertainties are included in the calculations. We show that the cancer risk uncertainty, defined as the ratio of the upper value of 95% confidence interval (CI) to the point estimate is about 4-fold for lunar and Mars mission risk projections. For short-stay lunar missions ( 180d) or Mars missions, GCR risks may exceed radiation risk limits that are based on acceptable levels of risk. For example, the upper 95% CI exceeding 10% fatal risk for males and females on a Mars mission. For reducing GCR cancer risks, shielding materials are marginally effective because of the penetrating nature of GCR and secondary radiation produced in tissue by relativistic particles. At the present time, polyethylene or carbon composite shielding cannot be shown to significantly reduce risk compared to aluminum shielding based on a significance test that accounts for radiobiology uncertainties in GCR risk projection

  5. Penetration portion shielding structure

    International Nuclear Information System (INIS)

    Hayashi, Katsumi; Narita, Hitoshi; Handa, Hiroyuki; Takeuchi, Jun; Tozuka, Fumio.

    1994-01-01

    Openings of a plurality of shieldings for penetration members are aligned to each other, and penetration members are inserted from the openings. Then, the openings of the plurality of shielding members are slightly displaced with each other to make the penetration portions into a helical configuration, so that leakage of radiation is reduced. Upon removal of the members, reverse operation is conducted. When a flowable shielding material is used, the penetration portions are constituted with two plates having previously formed openings and pipes for connecting the openings with each other and a vessel covering the entire of them. After passing the penetration members such as a cable, the relative position of the two plates is changed by twisting, to form a helical configuration which reduces radiation leakage. Since they are bent into the helical configuration, shielding performance is extremely improved compared with a case that radiation leakage is caused from an opening of a straight pipe. In addition, since they can be returned to straight pipes, attachment, detachment and maintenance can be conducted easily. (N.H.)

  6. The effect of some organic and non-organic additions on the shielding and mechanical properties of radiation shielding concrete

    International Nuclear Information System (INIS)

    Kharita, M. H.; Yousef, S.; Al-Nassar, M.

    2011-04-01

    Few studies on the effect of some additives on the shielding properties of concrete have been carried out in this research. These studies included the effect of carbon powder, boron compounds, and waste polyethylene. The effect of water to cement ratio has been studied too. The research results showed that carbon powder and some boron compounds could be used to improve shielding concrete properties, and the possibility to add waste polyethylene in shielding concrete without effects on shielding properties. No significant effect for water to cement ratio on shielding properties of concrete. (author)

  7. A study on the calculation of the shielding wall thickness in medical linear accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Yeon [Dept. of Radiation Oncology, Dongnam Ins. of Radiological and Medical Science, Busan (Korea, Republic of); Park, Eun Tae [Dept. of Radiation Oncology, Inje University Busan Paik Hospital, Busan (Korea, Republic of); Kim, Jung Hoon [Dept. of Radiological science, college of health sciences, Catholic University of Pusan, Busan (Korea, Republic of)

    2017-06-15

    The purpose of this study is to calculate the thickness of shielding for concrete which is mainly used for radiation shielding and study of the walls constructed to shield medical linear accelerator. The optimal shielding thickness was calculated using MCNPX(Ver.2.5.0) for 10 MV of photon beam energy generated by linear accelerator. As a result, the TVL for photon shielding was formed at 50⁓100 cm for pure concrete and concrete with Boron+polyethylene at 80⁓100 cm. The neutron shielding was calculated 100⁓140 cm for pure concrete and concrete with Boron+polyethylene at 90⁓100 cm. Based on this study, the concrete is considered to be most efficient method of using steel plates and adding Boron+polyethylene th the concrete.

  8. Technical products for radiation shielding. Shield assembled from lead blocks for radiation protection. General technical requirements

    International Nuclear Information System (INIS)

    1981-01-01

    The object of this standard description is the general technological requirements of 50 and 100 mm thick radiation protection shields assembled from lead blocks. The standard contains the definitions, types, parameters and dimensions of shields, their technical and acceptance criteria with testing methods, tagging, packaging, transportation and storage requirements, producer's liability. Some illustrated assembling examples, preferred parameters and dosimetry methods for shield inspection are given. (R.P.)

  9. Shield support frame. Schildausbaugestell

    Energy Technology Data Exchange (ETDEWEB)

    Plaga, K.

    1981-09-17

    A powered shield support frame for coal sheds is described comprising of two bottom sliding shoes, a large area gob shield and a larg area roof assembly, all joined movable together. The sliding shoes and the gob shield are joined by a lemniscate guide. Two hydraulic props are arranged at the face-side at one third of the length of the sliding shoes and at the goaf-side at one third of the length of the roof assembly. A nearly horizontal lying pushing prop unit joins the bottom wall sliding shoes to the goaf-side lemniscate guide. This assembly can be applied to seams with a thickness down to 45 cm. (OGR).

  10. Reactor head shielding apparatus

    International Nuclear Information System (INIS)

    Schukei, G.E.; Roebelen, G.J.

    1992-01-01

    This patent describes a nuclear reactor head shielding apparatus for mounting on spaced reactor head lifting members radially inwardly of the head bolts. It comprises a frame of sections for mounting on the lifting members and extending around the top central area of the head, mounting means for so mounting the frame sections, including downwardly projecting members on the frame sections and complementary upwardly open recessed members for fastening to the lifting members for receiving the downwardly projecting members when the frame sections are lowered thereto with lead shielding supported thereby on means for hanging lead shielding on the frame to minimize radiation exposure or personnel working with the head bolts or in the vicinity thereof

  11. Thermal design of top shield for PFBR

    International Nuclear Information System (INIS)

    Gajapathy, R.; Jalaludeen, S.; Selvaraj, A.; Bhoje, S.B.

    1988-01-01

    India's Liquid Metal Cooled Fast Breeder Reactor programme started with the construction of loop type 13MW(e) Fast Breeder Test Reactor (FBTR) which attained criticality in October 1985. With the experience of FBTR, the design work on pool type 500 MW(e) Prototype Fast Breeder Reactor (PFBR) which will be a forerunner for future commercial fast breeder reactors, has been started. The Top Shield forms the cover for the main vessel which contains the primary circuit. Argon cover gas separates the Top Shield from the free level of hot sodium pool (803K). The Top Shield which is of box type construction consists of control plug, two rotatable plugs and roof slab, assembled together, which provide biological shielding, thermal shielding and leak tight containment at the top of the main vessel. Heat is transferred from the sodium pool to the Top Shield through argon cover gas and through components supported by it and dipped in the sodium pool. The Top Shield should be maintained at the desired operating temperature by incorporating a cooling system inside it. Insulation may be provided below the bottom plate to reduce the heat load to the cooling system, if required. The thermal design of Top Shield consists of estimation of heat transfer to the Top Shield, selection of operating temperature, assessment of insulation requirement, design of cooling system and evaluation of transient temperature changes

  12. Preliminary neutron shielding calculations of the electronics in the EAST BES systems focusing on neutron induced displacement damage

    Energy Technology Data Exchange (ETDEWEB)

    Náfrádi, Gábor, E-mail: nafradi@reak.bme.hu [Institute of Nuclear Techniques (NTI), Budapest University of Technology and Economics (BME), H-1111 Budapest (Hungary); Kovácsik, Ákos, E-mail: kovacsik.akos@reak.bme.hu [Institute of Nuclear Techniques (NTI), Budapest University of Technology and Economics (BME), H-1111 Budapest (Hungary); Németh, József, E-mail: nemeth.jozsef@wigner.mta.hu [Institute for Particle and Nuclear Physics, Wigner Research Centre for Physics (Wigner RCP), Hungarian Academy of Sciences (HAS), POB 49, 1525 Budapest (Hungary); Pór, Gábor, E-mail: por@reak.bme.hu [Institute of Nuclear Techniques (NTI), Budapest University of Technology and Economics (BME), H-1111 Budapest (Hungary); Zoletnik, Sándor, E-mail: zoletnik.sandor@wigner.mta.hu [Institute for Particle and Nuclear Physics, Wigner Research Centre for Physics (Wigner RCP), Hungarian Academy of Sciences (HAS), POB 49, 1525 Budapest (Hungary)

    2016-11-15

    Monte Carlo N-Particle (MCNP) calculations were carried out to compare neutron shielding capabilities of three frequently used neutron shielding materials: polyethylene without neutron absorbers, polyethylene with boron absorbers and polyethylene with lithium absorbers, according to Non Ionizing Energy Loss (NIEL). The results of 1D shielding calculations showed that simple neutron moderating materials can provide sufficient and cheap shielding against 2.45 MeV and 14.1 MeV fusion neutrons, in terms of 1 MeV neutron equivalent flux, in silicon targets, which is the most commonly used material of electronic components. Based on these results a new shielding concept is proposed which can be taken into consideration where the reduction of displacement damage is the main goal and the free space available for shielding is limited. Based on this shielding concept detailed 3D calculations were carried out to describe the properties of the neutron shielding of the Beam Emission Spectroscopy (BES) system installed at the EAST tokamak.

  13. Radiation Attenuation and Stability of ClearView Radiation Shielding TM-A Transparent Liquid High Radiation Shield.

    Science.gov (United States)

    Bakshi, Jayeesh

    2018-04-01

    Radiation exposure is a limiting factor to work in sensitive environments seen in nuclear power and test reactors, medical isotope production facilities, spent fuel handling, etc. The established choice for high radiation shielding is lead (Pb), which is toxic, heavy, and abidance by RoHS. Concrete, leaded (Pb) bricks are used as construction materials in nuclear facilities, vaults, and hot cells for radioisotope production. Existing transparent shielding such as leaded glass provides minimal shielding attenuation in radiotherapy procedures, which in some cases is not sufficient. To make working in radioactive environments more practicable while resolving the lead (Pb) issue, a transparent, lightweight, liquid, and lead-free high radiation shield-ClearView Radiation Shielding-(Radium Incorporated, 463 Dinwiddie Ave, Waynesboro, VA). was developed. This paper presents the motivation for developing ClearView, characterization of certain aspects of its use and performance, and its specific attenuation testing. Gamma attenuation testing was done using a 1.11 × 10 Bq Co source and ANSI/HPS-N 13.11 standard. Transparency with increasing thickness, time stability of liquid state, measurements of physical properties, and performance in freezing temperatures are reported. This paper also presents a comparison of ClearView with existing radiation shields. Excerpts from LaSalle nuclear power plant are included, giving additional validation. Results demonstrated and strengthened the expected performance of ClearView as a radiation shield. Due to the proprietary nature of the work, some information is withheld.

  14. Evaluation of Neutron shielding efficiency of Metal hydrides

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Sang Hwan; Chae, San; Kim, Yong Soo [Hanyang University, Seoul (Korea, Republic of)

    2012-05-15

    Neutron shielding is achieved of interaction with material by moderation and absorption. Material that contains large amounts hydrogen atoms which are almost same neutron atomic weight is suited for fast neutron shielding material. Therefore, polymers containing high density hydrogen atom are being used for fast neutron shielding. On the other hand, composite materials containing high thermal neutron absorption cross section atom (Li, B, etc) are being used for thermal neutron shielding. However, these materials have low fast neutron absorption cross section. Therefore, these materials are not suited for fast neutron shielding. Hydrogen which has outstanding neutron energy reduction ability has very low thermal neutron absorption cross section, almost cannot be used for thermal neutron shielding. In this case, a large atomic number material (Pb, U, etc.) has been used. Thus, metal hydrides are considered as complement to concrete shielding material. Because metal hydrides contain high hydrogen density and elements with high atomic number. In this research neutron shielding performance and characteristic of nuclear about metal hydrides ((TiH{sub 2}, ZrH{sub 2}, HfH{sub 2}) is evaluated by experiment and MCNPX using {sup 252}Cf neutron source as purpose development shielding material to developed shielding material

  15. Beta Bremsstrahlung dose in concrete shielding

    Energy Technology Data Exchange (ETDEWEB)

    Manjunatha, H.C., E-mail: manjunatha@rediffmail.com [Department of Physics, Government college for women, Kolar 563101, Karnataka (India); Chandrika, B.M. [Shravana, 592, Ist Cross, Behind St.Anne s School, PC Extension, Kolar 563101, Karnataka (India); Rudraswamy, B. [Department of Physics, Bangalore University, Bangalore 560056, Karnataka (India); Sankarshan, B.M. [Shravana, 592, Ist Cross, Behind St.Anne s School, PC Extension, Kolar 563101, Karnataka (India)

    2012-05-11

    In a nuclear reactor, beta nuclides are released during nuclear reactions. These betas interact with shielding concrete and produces external Bremsstrahlung (EB) radiation. To estimate Bremsstrahlung dose and shield efficiency in concrete, it is essential to know Bremsstrahlung distribution or spectra. The present work formulated a new method to evaluate the EB spectrum and hence Bremsstrahlung dose of beta nuclides ({sup 32}P, {sup 89}Sr, {sup 90}Sr-{sup 90}Y, {sup 90}Y, {sup 91}Y, {sup 208}Tl, {sup 210}Bi, {sup 234}Pa and {sup 40}K) in concrete. The Bremsstrahlung yield of these beta nuclides in concrete is also estimated. The Bremsstrahlung yield in concrete due to {sup 90}Sr-{sup 90}Y is higher than those of other given nuclides. This estimated spectrum is accurate because it is based on more accurate modified atomic number (Z{sub mod}) and Seltzer's data, where an electron-electron interaction is also included. Presented data in concrete provide a quick and convenient reference for radiation protection. The present methodology can be used to calculate the Bremsstrahlung dose in nuclear shielding materials. It can be quickly employed to give a first pass dose estimate prior to a more detailed experimental study. - Highlights: Black-Right-Pointing-Pointer Betas released in a nuclear reactor interact with shielding concrete and produces Bremsstrahlung. Black-Right-Pointing-Pointer The present work formulated a new method to evaluate the Bremsstrahlung spectrum and dose in concrete. Black-Right-Pointing-Pointer Presented data in concrete provide a quick and convenient reference for radiation protection.

  16. Radiation Shielding of Lunar Regolith/Polyethylene Composites and Lunar Regolith/Water Mixtures

    Science.gov (United States)

    Johnson, Quincy F.; Gersey, Brad; Wilkins, Richard; Zhou, Jianren

    2011-01-01

    Space radiation is a complex mixed field of ionizing radiation that can pose hazardous risks to sophisticated electronics and humans. Mission planning for lunar exploration and long duration habitat construction will face tremendous challenges of shielding against various types of space radiation in an attempt to minimize the detrimental effects it may have on materials, electronics, and humans. In late 2009, the Lunar Crater Observation and Sensing Satellite (LCROSS) discovered that water content in lunar regolith found in certain areas on the moon can be up to 5.6 +/-2.8 weight percent (wt%) [A. Colaprete, et. al., Science, Vol. 330, 463 (2010). ]. In this work, shielding studies were performed utilizing ultra high molecular weight polyethylene (UHMWPE) and aluminum, both being standard space shielding materials, simulated lunar regolith/ polyethylene composites, and simulated lunar regolith mixed with UHMWPE particles and water. Based on the LCROSS findings, radiation shielding experiments were conducted to test for shielding efficiency of regolith/UHMWPE/water mixtures with various percentages of water to compare relative shielding characteristics of these materials. One set of radiation studies were performed using the proton synchrotron at the Loma Linda Medical University where high energy protons similar to those found on the surface of the moon can be generated. A similar experimental protocol was also used at a high energy spalation neutron source at Los Alamos Neutron Science Center (LANSCE). These experiments studied the shielding efficiency against secondary neutrons, another major component of space radiation field. In both the proton and neutron studies, shielding efficiency was determined by utilizing a tissue equivalent proportional counter (TEPC) behind various thicknesses of shielding composite panels or mixture materials. Preliminary results from these studies indicated that adding 2 wt% water to regolith particles could increase shielding of

  17. A shielding chamber for the Rossendorf whole body counter

    International Nuclear Information System (INIS)

    Beutmann, A.; Ebert, S.; Kaden, M.; Loehnert, D.; Doerfel, H.R.; Schreiber, W.; Helbig, S.

    2016-01-01

    In connection with the relocation of the incorporation measurement point operated by the VKTA, a new shielding chamber was designed. The development of the new shielding chamber will be shown based on the design study by IDEA System and the inquiries for material availability, procurement of material and assembly technology up to fabrication, assembly and completion of the chamber. The accompanying background measurements through In-situ gamma spectrometry and first experiences with incorporation measurements at the new In-Vivo measurement facility are shown.

  18. Characteristic Determination Of Self Shielding Factor And Cadmium Ratio Of Cylindrical Probe

    International Nuclear Information System (INIS)

    Hamzah, Amir; Budi R, Ita; Pinem, Suriam

    1996-01-01

    Determination of thermal, epithermal and total self shielding factor and cadmium ratio of cylindrical probe has been done by measurement and calculation. Self shielding factor can be determined by dividing probe activity to Al-alloy probe activity. Due to the lack of cylindrical probe made of Al-alloy, self shielding factor can be determined by parabolic extrapolation of measured activities to 0 cm radius to divide those activities. Theoretically, self shielding factor can be determined by making numerical solution of two dimensional integral equations using Romberg method. To simplify, the calculation is based on single collision theory with the assumption of monoenergetic neutron and isotropic distribution. For gold cylindrical probe, the calculation results are quite close to the measurement one with the relative discrepancy for activities, cadmium ratio and self shielding factor of bare probe are less then 11.5%, 3,5% and 1.5% respectively. The program can be used for the calculation of other kinds of cylindrical probes. Due to dependency to radius, cylindrical probe made of copper has the best characteristic of self shielding factor and cadmium ratio

  19. Radiation dose reduction by water shield

    International Nuclear Information System (INIS)

    Zeb, J.; Arshed, W.; Ahmad, S.S.

    2007-06-01

    This report is an operational manual of shielding software W-Shielder, developed at Health Physics Division (HPD), Pakistan Institute of Nuclear Science and Technology (PINSTECH), Pakistan Atomic Energy Commission. The software estimates shielding thickness for photons having their energy in the range 0.5 to 10 MeV. To compute the shield thickness, self absorption in the source has been neglected and the source has been assumed as a point source. Water is used as a shielding material in this software. The software is helpful in estimating the water thickness for safe handling, storage of gamma emitting radionuclide. (author)

  20. Technology development for radiation shielding analysis

    International Nuclear Information System (INIS)

    Ha, Jung Woo; Lee, Jae Kee; Kim, Jong Kyung

    1986-12-01

    Radiation shielding analysis in nuclear engineering fields is an important technology which is needed for the calculation of reactor shielding as well as radiation related safety problems in nuclear facilities. Moreover, the design technology required in high level radioactive waste management and disposal facilities is faced on serious problems with rapidly glowing nuclear industry development, and more advanced technology has to be developed for tomorrow. The main purpose of this study is therefore to build up the self supporting ability of technology development for the radiation shielding analysis in order to achieve successive development of nuclear industry. It is concluded that basic shielding calculations are possible to handle and analyze by using our current technology, but more advanced technology is still needed and has to be learned for the degree of accuracy in two-dimensional shielding calculation. (Author)

  1. Shielding designs and tests of a new exclusive ship for transporting spent nuclear fuels

    International Nuclear Information System (INIS)

    Ono, M.; Ito, D.; Kitano, T.; Ueki, K.; Akiyama, H.; Obara, I.; Sanui, T.

    2000-01-01

    The Rokuei-Maru, a ship built specially for the transport of spent nuclear fuels in casks, was launched April in 1996. She is the first ship to comply with special Japanese regulations, KAISA 520, based on the INF code. DOT3.5 and MCNP-4A were used for the evaluation of dose equivalent rates of her shielding structures. On-board gamma-ray shielding tests were executed to confirm the effectiveness of the ship's shielding performance. The tests confirmed that effective shielding has been achieved and the dose equivalent rate in the accommodation and other inhabited spaces is sufficiently lower than the regulated limitations. This was achieved by employing the appropriate calculation methods and shielding materials. (author)

  2. Self-shielding characteristics of aqueous self-cooled blankets for next generation fusion devices

    International Nuclear Information System (INIS)

    Pelloni, S.; Cheng, E.T.; Embrechts, M.J.

    1987-11-01

    The present study examines self-shielding characteristics for two aqueous self-cooled tritium producing driver blankets for next generation fusion devices. The aqueous Self-Cooled Blanket concept (ASCB) is a very simple blanket concept that relies on just structural material and coolant. Lithium compounds are dissolved in water to provide for tritium production. An ASCB driver blanket would provide a low technology and low temperature environment for blanket test modules in a next generation fusion reactor. The primary functions of such a blanket would be shielding, energy removal and tritium production. One driver blanket considered in this study concept relates to the one proposed for the Next European Torus (NET), while the second concept is indicative for the inboard shield design for the Engineering Test Reactor proposed by the USA (TIBER II/ETR). The driver blanket for NET is based on stainless steel for the structural material and aqueous solution, while the inboard shielding blanket for TIBER II/ETR is based on a tungsten/aqueous solution combination. The purpose of this study is to investigate self-shielding and heterogeneity effects in aqueous self-cooled blankets. It is found that no significant gains in tritium breeding can be achieved in the stainless steel blanket if spatial and energy self-shielding effects are considered, and the heterogeneity effects are also insignificant. The tungsten blanket shows a 5 percent increase in tritium production in the shielding blanket when energy and spatial self-shielding effects are accounted for. However, the tungsten blanket shows a drastic increase in the tritium breeding ratio due to heterogeneity effects. (author) 17 refs., 9 figs., 9 tabs

  3. Shielding performance of the NET vacuum vessel

    International Nuclear Information System (INIS)

    Arkuszewski, J.J.; Jaeger, J.F.

    1988-01-01

    To corroborate 1-D deterministic shielding calculations on the Next European Torus (NET) vacuum vessel/shield and shielding blanket, 3-D Monte Carlo calculations have been done with the MCNP code. This should provide information on the poloidal and the toroidal variations. Plasma source simulation and the geometrical model are described, as are other assumptions. The calculations are based on the extended plasma power of 714 MW. The results reported here are the heat deposition in various parts of the device, on the one hand, and the neutron and photon currents at the outer boundary of the vacuum vessel, on the other hand. The latter are needed for the detailed design of the super-conducting magnetic coils. A reasonable statistics has been obtained on the outboard side of the torus, though this cannot be said for the inboard side. The inboard is, however, much more toroidally symmetric than the outboard, so that other methods could be applied such as 2-D deterministic calculations, for instance. (author) 4 refs., 44 figs., 42 tabs

  4. Radiation shielding for neutron guides

    International Nuclear Information System (INIS)

    Ersez, T.; Braoudakis, G.; Osborn, J.C.

    2005-01-01

    Full text: Models of the neutron guide shielding for the out of bunker guides on the thermal and cold neutron beam lines of the OPAL Reactor (ANSTO) were constructed using the Monte Carlo code MCNP 4B. The neutrons that were not reflected inside the guides but were absorbed by the supermirror (SM) layers were noted to be a significant source of gammas. Gammas also arise from neutrons absorbed by the B, Si, Na and K contained in the glass. The proposed shielding design has produced compact shielding assemblies. These arrangements are consistent with safety requirements, floor load limits, and cost constraints. To verify the design a prototype was assembled consisting of 120mm thick Pb(96%)Sb(4%) walls resting on a concrete block. There was good agreement between experimental measurements and calculated dose rates for bulk shield regions. (authors)

  5. Shielding calculations. Optimization vs. Paradigms

    International Nuclear Information System (INIS)

    Cornejo Diaz, Nestor; Hernandez Saiz, Alejandro; Martinez Gonzalez, Alina

    2005-01-01

    Many radiation shielding barriers in Cuba have been designed according to the criterion of Maxi-mum Projected Dose Rates. This fact has created the paradigm of low dose rates. Because of this, dose rate levels greater than units of Sv.h-1 would be considered unacceptable by many specialists, regardless of the real exposure times. Nowadays many shielding barriers are being designed using dose constraints in real exposure times. Behind the new barriers, dose rates could be notably greater than those behind the traditional ones, and it does not imply inadequate designs or constructive errors. In this work were obtained significant differences in dose rate levels and shield-ing thicknesses calculated by both methods for some typical installations. The work concludes that real exposure time approach is more adequate in order to optimise Radiation Protection, although this method should be carefully applied

  6. Radiation shielding for neutron guides

    International Nuclear Information System (INIS)

    Ersez, T.; Braoudakis, G.; Osborn, J.C.

    2006-01-01

    Models of the neutron guide shielding for the out of bunker guides on the thermal and cold neutron beam lines of the OPAL Reactor (ANSTO) were constructed using the Monte Carlo code MCNP 4B. The neutrons that were not reflected inside the guides but were absorbed by the supermirror (SM) layers were noted to be a significant source of gammas. Gammas also arise from neutrons absorbed by the B, Si, Na and K contained in the glass. The proposed shielding design has produced compact shielding assemblies. These arrangements are consistent with safety requirements, floor load limits, and cost constraints. To verify the design a prototype was assembled consisting of 120 mm thick Pb(96%)Sb(4%) walls resting on a concrete block. There was good agreement between experimental measurements and calculated dose rates for bulk shield regions

  7. Radiation shielding bricks

    International Nuclear Information System (INIS)

    Crowe, G.J.W.

    1983-01-01

    A radiation shielding brick for use in building dry walls to form radiation proof enclosures and other structures is described. It is square in shape and comprises a sandwich of an inner layer of lead or similar shielding material between outer layers of plastics material, for structural stability. The ability to mechanically interlock adjacent bricks is provided by shaping the edges as cooperating external and internal V-sections. Relatively leak-free joints are ensured by enlarging the width of the inner layer in the edge region. (author)

  8. The use of nipple shields: A review

    Directory of Open Access Journals (Sweden)

    Selina Chow

    2016-11-01

    Full Text Available A nipple shield is a breastfeeding aid with a nipple-shaped shield that is positioned over the nipple and areola prior to nursing. Nipple shields are usually recommended to mothers with flat nipples or in cases in which there is a failure of the baby to effectively latch onto the breast within the first two days postpartum. The use of nipple shields is a controversial topic in the field of lactation. Its use has been an issue in the clinical literature since some older studies discovered reduced breast milk transfer when using nipple shields, while more recent studies reported successful breastfeeding outcomes. The purpose of this review was to examine the evidence and outcomes with nipple shield use. Methods: A literature search was conducted in Ovid MEDLINE, OLDMEDLINE, EMBASE Classic, EMBASE, Cochrane Central Register of Controlled Trials and CINAHL. The primary endpoint was any breastfeeding outcome following nipple shield use. Secondary endpoints included the reasons for nipple shield use and the average/median length of use. For the analysis, we examined the effect of nipple shield use on physiological responses, premature infants, mothers’ experiences, and health professionals’ experiences. Results: The literature search yielded 261 articles, 14 of which were included in this review. Of these 14 articles, three reported on physiological responses, two reported on premature infants, eight reported on mothers’ experiences, and one reported on health professionals’ experiences. Conclusion: Through examining the use of nipple shields, further insight is provided on the advantages and disadvantages of this practice, thus allowing clinicians and researchers to address improvements on areas that will benefit mothers and infants the most.

  9. A study of gamma shielding

    International Nuclear Information System (INIS)

    Roogtanakait, N.

    1981-01-01

    Gamma rays have high penetration power and its attenuation depends upon the thickness and the attenuation coefficient of the shield, so it is necessary to use the high density shield to attenuate the gamma rays. Heavy concrete is considered to be used for high radiation laboratory and the testing of the shielding ability and compressibility of various types of heavy concrete composed of baryte, hematite, ilmenite and galena is carried out. The results of this study show that baryte-ilmenite concrete is the most suitable for high radiation laboratory in Thailand

  10. Validation of SCALE code package on high performance neutron shields

    International Nuclear Information System (INIS)

    Bace, M.; Jecmenica, R.; Smuc, T.

    1999-01-01

    The shielding ability and other properties of new high performance neutron shielding materials from the KRAFTON series have been recently published. A comparison of the published experimental and MCNP results for the two materials of the KRAFTON series, with our own calculations has been done. Two control modules of the SCALE-4.4 code system have been used, one of them based on one dimensional radiation transport analysis (SAS1) and other based on the three dimensional Monte Carlo method (SAS3). The comparison of the calculated neutron dose equivalent rates shows a good agreement between experimental and calculated results for the KRAFTON-N2 material.. Our results indicate that the N2-M-N2 sandwich type is approximately 10% inferior as neutron shield to the KRAFTON-N2 material. All values of neutron dose equivalent obtained by SAS1 are approximately 25% lower in comparison with the SAS3 results, which indicates proportions of discrepancies introduced by one-dimensional geometry approximation.(author)

  11. Neutron shielding performance of water-extended polyester

    International Nuclear Information System (INIS)

    Vega Carrillo, H.R.; Manzanares-Acuna, E.; Hernandez-Davila, V.M.; Vega Carrillo, H.R.; Hernandez-Davila, V.M.; Gallego, E.; Lorente, A.

    2006-01-01

    A Monte Carlo study to determine the shielding features to neutrons of water-extended polyester (WEP) was carried out. Materials with low atomic number are predominantly used for neutron shielding because these materials effectively attenuate neutrons, mainly through elastic and inelastic collisions. In addition to neutron attenuation properties, other desirable properties for neutron shielding materials include mechanical strength, stability, low cost, and ease of handling. During the selection of materials to design a neutron shield, prompt gamma production as well as radionuclide induced by neutron activation must be considered. In this investigation the Monte Carlo method (MCNP code) was used to evaluate the performance of a water-extended polyester shield designed for the transportation, storage, and use of a 252 Cf isotopic neutron source, for comparison the calculations were extended to water shielding, the bare source in vacuum and in air. (authors)

  12. Neutron shielding performance of water-extended polyester

    Energy Technology Data Exchange (ETDEWEB)

    Vega Carrillo, H.R.; Manzanares-Acuna, E.; Hernandez-Davila, V.M. [Zacatecas Univ. Autonoma, Nuclear Studies (Mexico); Vega Carrillo, H.R.; Hernandez-Davila, V.M. [Zacatecas Univ. Autonoma, Electric Engineering Academic Units (Mexico); Gallego, E.; Lorente, A. [Madrid Univ. Politecnica, cNuclear Engineering Department (Mexico)

    2006-07-01

    A Monte Carlo study to determine the shielding features to neutrons of water-extended polyester (WEP) was carried out. Materials with low atomic number are predominantly used for neutron shielding because these materials effectively attenuate neutrons, mainly through elastic and inelastic collisions. In addition to neutron attenuation properties, other desirable properties for neutron shielding materials include mechanical strength, stability, low cost, and ease of handling. During the selection of materials to design a neutron shield, prompt gamma production as well as radionuclide induced by neutron activation must be considered. In this investigation the Monte Carlo method (MCNP code) was used to evaluate the performance of a water-extended polyester shield designed for the transportation, storage, and use of a {sup 252}Cf isotopic neutron source, for comparison the calculations were extended to water shielding, the bare source in vacuum and in air. (authors)

  13. Shielded regenerative neutron detector

    International Nuclear Information System (INIS)

    Terhune, J.H.; Neissel, J.P.

    1978-01-01

    An ion chamber type neutron detector is disclosed which has a greatly extended lifespan. The detector includes a fission chamber containing a mixture of active and breeding material and a neutron shielding material. The breeding and shielding materials are selected to have similar or substantially matching neutron capture cross-sections so that their individual effects on increased detector life are mutually enhanced

  14. ANS shielding standards for light-water reactors

    International Nuclear Information System (INIS)

    Trubey, D.K.

    1982-01-01

    The purpose of the American Nuclear Society Standards Subcommittee, ANS-6, Radiation Protection and Shielding, is to develop standards for radiation protection and shield design, to provide shielding information to other standards-writing groups, and to develop standard reference shielding data and test problems. A total of seven published ANS-6 standards are now current. Additional projects of the subcommittee, now composed of nine working groups, include: standard reference data for multigroup cross sections, gamma-ray absorption coefficients and buildup factors, additional benchwork problems for shielding problems and energy spectrum unfolding, power plant zoning design for normal and accident conditions, process radiation monitors, and design for postaccident radiological conditions

  15. Cost benefit analysis of the radiological shielding of medical cyclotrons using a genetic algorithm

    International Nuclear Information System (INIS)

    Mukherjee, Bhaskar

    2001-01-01

    Adequate radiation shielding is vital to the safe operation of modern commercial medical cyclotrons producing large yields of short-lived radioisotopes. The radiological shielding constitutes a significant capital investment for any new cyclotron-based radioisotope production facility; hence, the shielding design requires an accurate cost-benefit analysis often based on a complex multi-variant optimization technique. This paper demonstrates the application of a Genetic Algorithm (GA) for the optimum design of the high yield target cave of a Medical Cyclotron radioisotope production facility based in Sydney, Australia. The GA is a novel optimization technique that mimics the Darwinian Evolution paradigm and is ideally suited to search for global optima in a large multi-dimensional solution space

  16. Recent developments in fusion first wall, blanket, and shield technology

    International Nuclear Information System (INIS)

    Nygren, R.E.

    1983-01-01

    This brief overview of first wall, blanket and shield technology reviews the changes and trends in important design issues in first wall, blanket and shield design and related technology from the 1970's to the 1980's. The emphasis is on base technology rather than either systems engineering or materials development. The review is limited to the two primary confinement systems, tokamaks and mirrors, and production of electricity as the primary goal for development

  17. Guide to shielding calculations for the design of fluoroscopic laboratory at 503 workshop AVN base Rawalpindi

    International Nuclear Information System (INIS)

    Din, J.U.; Ahmad, M.; Ashraf, M.M.; Khan, A.R.; Khan, A.A.

    1986-11-01

    Non-destructive testing plays an important role in assessing the quality of materials. Various methods are used for this purpose. Radiography by X-rays and gamma-rays is one of the NDT methods used. There are number of mathematical formulae used to estimate the required shielding for an X-ray tube operating at maximum rated voltage or a gamma radiation source having fixed energies. This report covers the shielding requirements for a 150 KV constant potential X-ray unit operating at maximum rated voltage. In addition, the report is a guide for the design of shielded enclosure required for X-rays machines in general. (orig./A.B.)

  18. Status of multigroup cross-section data for shielding applications

    International Nuclear Information System (INIS)

    Roussin, R.W.; Maskewitz, B.F.; Trubey, D.K.

    1983-01-01

    Multigroup cross-section libraries for shielding applications in formats for direct use in discrete ordinates or Monte Carlo codes have long been a part of the Data Library Collection (DLC) of the Radiation Shielding Information Center (RSIC). In recent years libraries in more flexible and comprehensive formats, which allow the user to derive his own problem-dependent sets, have been added to the collection. The current status of both types is described, as well as projections for adding data libraries based on ENDF/B-V

  19. Available data for house shielding estimates of Japanese atomic bomb survivors

    International Nuclear Information System (INIS)

    Woolson, William A.

    1987-01-01

    To make intelligent decisions concerning the methods to update the dosimetry assignments for the Japanese atomic bomb survivors, it is necessary to know the available shielding information that exists in uncoded form on paper and in coded form that can be directly accessed by the computer. The objective of this report is to provide a summary of the available shielding data, both in uncoded and coded form. This report is the result of visits to RERF in Hiroshima and Nagasaki in February and November 1983. The special assistance provided by Mr. Hiroaki Yamada at Hiroshima and Mr. Yoshio Okamoto at Nagasaki is acknowledged. They were in charge of the ABCC shielding sections at their respective locations and have been long involved in the RERF shielding program. Their familiarity with the methods, procedures, and data was of invaluable assistance in this work. The following sections of this report will provide a description of the information that is available in the shielding history files in uncoded form; a brief description of the various shielding methods that were used over the course of time from the T57D system to the present day T65D; and a description of the current coded data bases that can be accessed by computer

  20. An analytical solution to the shielding of Co 60 teletherapy rooms based on a semiempirical equation of photon attenuation

    International Nuclear Information System (INIS)

    Saez, D.G.; Hernandez, L.; Borroto, M.; Figueredo, M.

    1996-01-01

    A semiempirical equation of polynomial-exponential type is presented to describe the transmission data of Co-60 gamma radiation in finite materials of concrete and lead. This equation and the expression obtained for the relationship of scatter-to-incident exposure made easy the developing in computer of an analytical solution for shielding calculations of Co 60 teletherapy rooms, based on the procedures of the NCRP 49 and Simpkin's method. The standard error in the estimation of parameters is less than 1.7 % except for the attenuation of 150 'o' scattered radiation in concrete that resulted in 6.3 % for one of them. The shielding calculations were compared with the data in NCRP 49 for the same conditions with a correlation better than 99 %

  1. Description of Neblinichthys brevibracchium and N. echinasus from the upper Mazaruni River, Guyana (Siluriformes: Loricariidae, and recognition of N. roraima and N. yaravi as distinct species

    Directory of Open Access Journals (Sweden)

    Donald C. Taphorn

    Full Text Available Neblinichthys brevibracchium and N. echinasus are new sympatric species from upland tributaries of the Mazaruni River (Essequibo River basin of Guyana. These two new species are the first Neblinichthys reported from Guyana. Adult males of both new species have short pectoral-fin spines and several series of hypertrophied odontodes covering the entire dorsal surface and along the entire edge of the snout. They are distinguished from each other by dorsal-fin base length/standard length (18.1-22.8% in N. brevibracchium vs. 24.3-27.0% in N. echinasus, dorsal-anal distance/SL (13.7-18.3% in N. brevibracchium vs. 11.9-12.5% in N. echinasus, by having the snout decreasing in steep arc just anterior to eyes and then flattening in area anterior of nares in N. brevibracchium vs. the snout tapering shallowly and continuously from eyes to snout tip in N. echinasus; and by having the adpressed dorsal fin reaching the anterior preadipose plate in N. brevibracchium (vs. not reaching anterior preadipose plate in N. echinasus. They are distinguished from all congeners by lacking odontodes on the opercle (vs. odontodes present; and by completely lacking an iris operculum (vs. congeners with small iris operculum present or at least dorsal portion of iris flat instead of rounded. Neblinichthys echinasus and N. brevibracchium differ from all congeners by having a spotted or vermiculated pigment pattern on the abdomen (vs. abdomen plain; in N. echinasus the abdomen is darkly pigmented with bold white spots and in Neblinichthys brevibracchium the abdomen is light-colored with gray spots and vermiculations. Neblinichthys brevibracchium and N. echinasus differ from N. roraima by having one to two preadipose plates (vs. four or more. New observations revealed Neblinichthys roraima and N. yaravi to be distinct, with N. roraima having four or more preadipose plates and N. yaravi having one or two. Both are present in the upper río Caroní, an Orinoco tributary that drains

  2. New applications and developments in the neutron shielding

    Directory of Open Access Journals (Sweden)

    Uğur Fatma Aysun

    2017-01-01

    Full Text Available Shielding neutrons involve three steps that are slowing neutrons, absorption of neutrons, and impregnation of gamma rays. Neutrons slow down with thermal energy by hydrogen, water, paraffin, plastic. Hydrogenated materials are also very effective for the absorption of neutrons. Gamma rays are produced by neutron (radiation retention on the neutron shield, inelastic scattering, and degradation of activation products. If a source emits gamma rays at various energies, high-energy gamma rays sometimes specify shielding requirements. Multipurpose Materials for Neutron Shields; Concrete, especially with barium mixed in, can slow and absorb the neutrons, and shield the gamma rays. Plastic with boron is also a good multipurpose shielding material. In this study; new applications and developments in the area of neutron shielding will be discussed in terms of different materials.

  3. New applications and developments in the neutron shielding

    Science.gov (United States)

    Uğur, Fatma Aysun

    2017-09-01

    Shielding neutrons involve three steps that are slowing neutrons, absorption of neutrons, and impregnation of gamma rays. Neutrons slow down with thermal energy by hydrogen, water, paraffin, plastic. Hydrogenated materials are also very effective for the absorption of neutrons. Gamma rays are produced by neutron (radiation) retention on the neutron shield, inelastic scattering, and degradation of activation products. If a source emits gamma rays at various energies, high-energy gamma rays sometimes specify shielding requirements. Multipurpose Materials for Neutron Shields; Concrete, especially with barium mixed in, can slow and absorb the neutrons, and shield the gamma rays. Plastic with boron is also a good multipurpose shielding material. In this study; new applications and developments in the area of neutron shielding will be discussed in terms of different materials.

  4. Shielding consideration for the SSCL experimental halls

    International Nuclear Information System (INIS)

    Bull, J.; Coyne, J.; Mokhov, N.; Stapleton, G.

    1994-03-01

    The Superconducting Super Collider which is being designed and built in Waxahachie, Texas consists Of series of proton accelerators, culminating in a 20 Te proton on proton collider. The collider will be in a tunnel which will be 87 km in circumference and. on average about 30 meters underground. The present design calls for two large interaction halls on the east side of the ring. The shielding for these halls is being designed for an interaction rate of 10 9 Hz or 10 16 interactions per year, based on 10 7 seconds per operational year. SSC guidelines require that the shielding be designed to meet the criterion of 1mSv per year for open areas off site 2mSv per year for open areas on site, and 2mSv per year for controlled areas. Only radiation workers will be routinely allowed to work in controlled areas. It should be pointed that there is a potential for an accidental full beam loss in either of the experimental halls, and this event would consist of the loss of the full circulating beam up to 4 x 10 14 protons. With the present design. the calculated dose equivalent for this event is about 10% of the annual dose equivalent for the normal p-p interactions, so that die accident condition does not control the shielding. If, for instance, local shielding within the experimental hall is introduced into the calculations, this could change. The shielding requirements presented here are controlled by the normal p-p interactions. Three important questions were addressed in the present calculations. They are (1) the thickness of the roof over the experimental halls, (2) the configuration of the shafts and adits which give access to the halls, and (3) the problem of ground water and air activation

  5. Neutron shielding performance of water-extended polyester

    International Nuclear Information System (INIS)

    Vega Carrillo, H.R.; Manzanares-Acuna, E.; Hernandez-Davila, V.M.; Vega Carrillo, H.R.; Gallegoc, E.; Lorentec, A.; Hernandez-Davila, V.M.

    2006-01-01

    A Monte Carlo study to determine the shielding features to neutrons of water-extended polyester was carried out. Materials with low atomic number are predominantly used for neutron shielding because these materials effectively attenuate neutrons, mainly through elastic and inelastic collisions. In addition to neutron attenuation properties, other desirable properties for neutron shielding materials include mechanical strength, stability, low cost, and ease of handling. During the selection of materials to design a neutron shield, prompt gamma production as well as radionuclide induced by neutron activation must be considered. In this investigation the Monte Carlo method (M.C.N.P. code) was used to evaluate the performance of a water-extended polyester shield designed for the transportation, storage, and use of a 252 Cf isotopic neutron source, for comparison the calculations were extended to water shielding, the bare source in vacuum and in air. (authors)

  6. Shields for nuclear reactors

    International Nuclear Information System (INIS)

    Aspden, G.J.

    1984-01-01

    The patent concerns shields for nuclear reactors. The roof shield comprises a normally fixed radial outer portion, a radial inner portion rotatable about a vertical axis, and a connection between the inner and outer portions. In the event of hypothecal core disruption conditions, a cantilever system on the inner wall allows the upward movement of the inner wall, in order to prevent loss of containment. (UK)

  7. Shielding during x-ray examination of pediatric female patients with developmental dysplasia of the hip

    International Nuclear Information System (INIS)

    Tsai, Yi-Shan; Liu, Yi-Sheng; Chuang, Ming-Tsung; Wang, Chien-Kuo; Lai, Cheng-Shih; Tsai, Hong-Ming; Lu, Chia-Hsing; Lin, Chii-Jeng

    2014-01-01

    Patients with developmental dysplasia of the hip (DDH) generally undergo multiple x-ray examinations of both hip joints. During these examinations, the gonads are completely exposed to radiation, unless shielded. Although many types and sizes of gonad shields exist, they often do not provide adequate protection because of size and placement issues; additionally, these shields are frequently omitted for female patients. Our aim was to assess gonad protection during x-ray examination that is provided by gonad shields designed for individual female patients with DDH. We retrospectively retrieved data from the Picture Archiving and Communication System database; pelvic plain x-ray films from 766 females, 18 years old or younger, were included in our analysis. Based on x-ray measurements of the anterior superior iliac spine, we developed a system of gonad shield design that depended on the distance between anterior superior iliac spine markers. We custom-made shields and then examined shielding rates and shielding accuracy before and after these new shields became available. Standard (general-purpose) shields were used before our custom design project was implemented. The shielding rate and shielding accuracy were, respectively, 14.5% and 8.4% before the project was implemented and 72.7% and 32.2% after it was implemented. A shield that is more anatomically correct and available in several different sizes may increase the likelihood of gonad protection during pelvic x-ray examinations. (paper)

  8. Shielding during x-ray examination of pediatric female patients with developmental dysplasia of the hip.

    Science.gov (United States)

    Tsai, Yi-Shan; Liu, Yi-Sheng; Chuang, Ming-Tsung; Wang, Chien-Kuo; Lai, Cheng-Shih; Tsai, Hong-Ming; Lin, Chii-Jeng; Lu, Chia-Hsing

    2014-12-01

    Patients with developmental dysplasia of the hip (DDH) generally undergo multiple x-ray examinations of both hip joints. During these examinations, the gonads are completely exposed to radiation, unless shielded. Although many types and sizes of gonad shields exist, they often do not provide adequate protection because of size and placement issues; additionally, these shields are frequently omitted for female patients. Our aim was to assess gonad protection during x-ray examination that is provided by gonad shields designed for individual female patients with DDH.We retrospectively retrieved data from the Picture Archiving and Communication System database; pelvic plain x-ray films from 766 females, 18 years old or younger, were included in our analysis. Based on x-ray measurements of the anterior superior iliac spine, we developed a system of gonad shield design that depended on the distance between anterior superior iliac spine markers. We custom-made shields and then examined shielding rates and shielding accuracy before and after these new shields became available. Standard (general-purpose) shields were used before our custom design project was implemented. The shielding rate and shielding accuracy were, respectively, 14.5% and 8.4% before the project was implemented and 72.7% and 32.2% after it was implemented. A shield that is more anatomically correct and available in several different sizes may increase the likelihood of gonad protection during pelvic x-ray examinations.

  9. Shielding research in France

    Energy Technology Data Exchange (ETDEWEB)

    Lafore, P

    1964-10-01

    Shielding research as an independent subject in France dates from 1956. The importance of these studies has been reflected in the contribution which they have made to power reactor design and in the resultant savings in expenditure for civil engineering and machinery for the removal of mobile shields. The Reactor Shielding Research Division numbers approximately 60 persons and uses several experimental facilities. These include: NAIADE I, installed near the ZOE reactor and operating with a natural uranium slab 2 cm thick (an effective diameter of 60 cm is the one most commonly used); the TRITON pool-type reactor, mainly used in shielding studies, includes an active-water loop, by means of which the secondary shields required for light-water reactors can be studied; core, NEREIDE, which is situated near a 2 m x 2 m aluminium window enables a large neutron source to be placed in a compartment without water in which large-scale mock-ups can be mounted for the study, in particular, of neutron diffusion in large cavities, and of reactor shielding of greater thickness than that in NAIADE I; SAMES 600 keV accelerator is used for monoenergetic neutron studies. Instrumentation studies are an important part of the work, mainly in the measurement of fast neutrons and their spectra by activation detectors. Of late, attention has been directed towards the use of (n, n') (rhodium) reactions and of heavy detectors for low-flux measurements. The simultaneous use of a large number of detectors poses automation problems. With our installation we can count 16 detectors simultaneously. Neutron spectrum studies are conducted with nuclear emulsions and a lithium-6 semiconductor spectrometer. As to the materials used, the research carried out in France involves chiefly graphite, iron and concrete at various temperatures up to 800 deg C. Different compounds, borated and non-borated and of densities up to between 1 and 9 are under consideration. Problems connected with applications are

  10. MEANS FOR SHIELDING AND COOLING REACTORS

    Science.gov (United States)

    Wigner, E.P.; Ohlinger, L.A.; Young, G.J.; Weinberg, A.M.

    1959-02-10

    Reactors of the water-cooled type and a means for shielding such a rcactor to protect operating personnel from harmful radiation are discussed. In this reactor coolant tubes which contain the fissionable material extend vertically through a mass of moderator. Liquid coolant enters through the bottom of the coolant tubes and passes upwardly over the fissionable material. A shield tank is disposed over the top of the reactor and communicates through its bottom with the upper end of the coolant tubes. A hydrocarbon shielding fluid floats on the coolant within the shield tank. With this arrangements the upper face of the reactor can be opened to the atmosphere through the two superimposed liquid layers. A principal feature of the invention is that in the event radioactive fission products enter thc coolant stream. imposed layer of hydrocarbon reduces the intense radioactivity introduced into the layer over the reactors and permits removal of the offending fuel material by personnel shielded by the uncontaminated hydrocarbon layer.

  11. Development of HANARO ST3 shield

    International Nuclear Information System (INIS)

    Park, K. N.; Lee, J. S.; Shim, H. S.

    2004-12-01

    This report contains the design, fabrication and accurate installation of ST3 shield, which would be installed at ST3 beam port of HANARO. At first, we designed and fabricated ST3 shield casemate composed of 14 blocks. We filled it with heavy concrete, lead ingot and polyethylene that mixed B 4 C powder and epoxy. The average filling density of total shield casemate was 4.7g/cm 3 . The developed ST3 shield was installed at the ST3 beam port and the accuracy of installation for each beam path and channel was evaluated. We found that the extraction of neutron beam to meet the requirement of neutron spectrometer is possible. Also, we developed ancillary equipment such as BGU, quick shutter and exterior shield door for the effective opening and closing of neutron beam. As a result of this study, it was found that neutron spectrometer such as neutron reflectometer and high intensity powder diffractomater can be installed at the ST3 beam port

  12. Analytic Shielding Optimization to Reduce Crew Exposure to Ionizing Radiation Inside Space Vehicles

    Science.gov (United States)

    Gaza, Razvan; Cooper, Tim P.; Hanzo, Arthur; Hussein, Hesham; Jarvis, Kandy S.; Kimble, Ryan; Lee, Kerry T.; Patel, Chirag; Reddell, Brandon D.; Stoffle, Nicholas; hide

    2009-01-01

    A sustainable lunar architecture provides capabilities for leveraging out-of-service components for alternate uses. Discarded architecture elements may be used to provide ionizing radiation shielding to the crew habitat in case of a Solar Particle Event. The specific location relative to the vehicle where the additional shielding mass is placed, as corroborated with particularities of the vehicle design, has a large influence on protection gain. This effect is caused by the exponential- like decrease of radiation exposure with shielding mass thickness, which in turn determines that the most benefit from a given amount of shielding mass is obtained by placing it so that it preferentially augments protection in under-shielded areas of the vehicle exposed to the radiation environment. A novel analytic technique to derive an optimal shielding configuration was developed by Lockheed Martin during Design Analysis Cycle 3 (DAC-3) of the Orion Crew Exploration Vehicle (CEV). [1] Based on a detailed Computer Aided Design (CAD) model of the vehicle including a specific crew positioning scenario, a set of under-shielded vehicle regions can be identified as candidates for placement of additional shielding. Analytic tools are available to allow capturing an idealized supplemental shielding distribution in the CAD environment, which in turn is used as a reference for deriving a realistic shielding configuration from available vehicle components. While the analysis referenced in this communication applies particularly to the Orion vehicle, the general method can be applied to a large range of space exploration vehicles, including but not limited to lunar and Mars architecture components. In addition, the method can be immediately applied for optimization of radiation shielding provided to sensitive electronic components.

  13. Cage for shield-type support. Schildausbaugestell

    Energy Technology Data Exchange (ETDEWEB)

    Harryers, W; Blumenthal, G; Irresberger, H

    1981-08-13

    A cage for shield-type support containing a fracture shield supported by a hydraulic stamp and a projecting roof bar was constructed in such a way that no cellular shirt is needed to timber the caved room. The roof bar which is linked at a joint axis at the face-side end of the fracture shield is formed at the face side as a multiply foldable bar. (HGOE).

  14. Technical notes. Rational approximations for cross-section space-shielding in doubly heterogeneous systems

    International Nuclear Information System (INIS)

    Stamatelatos, M.G.

    1976-01-01

    A simple yet accurate method of space-shielding cross sections in a doubly heterogeneous high-temperature gas-cooled reactor (HTGR) system using collision probabilities and rational approximations is presented. Unlike other more elaborate methods, this method does not require point-wise cross sections that are not explicitly generated in most popular cross-section codes. Consequently, this method makes double heterogeneity space-shielding possible for cross-section codes that do not proceed via point-wise cross sections and that usually allow only for single (fuel-rod) heterogeneity cross-section space-shielding. Results of calculations based on this method compare well with results of calculations based on more elaborate methods using point-wise cross sections. Moreover, the systematic trend of the difference between the results from this method and those from the more elaborate methods used for comparison supports the already existent opinion that the latter methods tend to overestimate the space-shielding cross-section correction in doubly heterogeneous HTGR systems

  15. Revised neutral gas shielding model for pellet ablation - combined neutral and plasma shielding

    International Nuclear Information System (INIS)

    Houlberg, W.A.; Schuresko, D.D.; Attenberger, S.E.

    1986-01-01

    The ablation and penetration of pellets in early ORMAK and ISX-A experiments were reliably predicted by the neutral gas shielding model of Milora and Foster. These experiments demonstrated that the principle components of the model - a self-generated shield which reduces the heat flux at the plasma surface - were correct. In more recent experiments with higher temperature plasmas, this model consistently predicts greater penetration than observed in the experiments. Upgarding known limitations of the original model brings the predicted and observed penetration values into agreement. These improvements include: (1) treating the incident electrons as having distribution in energy rather than being monoenergetic; (2) including the shielding effects of cold, dense plasma extending along the magnetic field outside the neutral shield; and (3) modifying the finite plasma, self-limiting incident heat flux so that it represents a collisionless plasma limit rather than a collisional limit. Comparisons are made between the models for a selection of ISX-B Alcator-C, and TFTR shots. The net effect of the changes in the model is an increase in pellet ablation rates and decrease in penetration for current and future experiments

  16. Heating profiles on ICRF antenna Faraday shields

    International Nuclear Information System (INIS)

    Taylor, D.J.; Baity, F.W.; Hahs, C.L. Riemer, B.W.; Ryan, D.M.; Williamson, D.E.

    1992-01-01

    Poor definition of the heating profiles that occur during normal operation of Faraday shields for ion cyclotron resonant frequency (ICRF) antennas has complicated the mechanical design of ICRF system components. This paper reports that at Oak Ridge National Laboratory (ORNL), Faraday shield analysis is being used in defining rf heating profiles. In recent numerical analyses of proposed hardware for the Burning Plasma Experiment (BPX) and DIII-D, rf magnetic fields at Faraday shield surfaces were calculated, providing realistic predictions of the induced skin currents flowing on the shield elements and the resulting dissipated power profile. Detailed measurements on mock-ups of the Faraday shields for DIII-D and the Tokamak Fusion Test Reactor (TFTR) confirmed the predicted magnetic field distributions. A conceptual design for an uncooled Faraday shield for the BPX ion cyclotron resonance heating (ICRH) antenna, which should withstand the proposed long-pulse operation, has been completed. The analytical effort is described in detail, with emphasis on the design work for the BPX ICRH antenna conceptual design and for the replacement Faraday shield for the DIII-D FWCD antenna. Results of analyses are shown, and configuration issues involved in component modeling are discussed

  17. Shielding calculation for bremsstrahlung from β-emitters

    International Nuclear Information System (INIS)

    Ichimiya, Tsutomu

    1990-01-01

    Accompanying the revision of radiation injury prevention law, the shielding calculation method for photon corresponding to the dose equivalent was shown. However, regarding the electron from β decay nuclide and bremsstrahlung caused by shielding material, the shielding calculation method corresponding to the 1 cm dose equivalent has not been reported, hence, in this report, the spectrum of β-ray is calculated and the 1 cm dose equivalent transmission rate of the bremsstrahlung was calculated for three kinds of shielding materials (iron, lead, concrete). As the result of consideration, it is sufficient to think about the bremsstrahlung due to negative electron emission accompanying β-decay. In β-decay, electrons which constitute the continuous spectrum with maximum energy are emitted. The shape of the spectrum differs with nuclides. The maximum energy of β-ray of generally used nuclides is mostly below 3MeV and, besides, the electron ray itself is easily shielded, while the strength of bremsstrahlung depends on the atomic number of shielding materials and its generating mechanism is complicated. In this report, the actual shielding calculation method for bremsstrahlung is shown with regard to the most frequently used β-decay nuclides. (M.T.)

  18. Preliminary evaluation of FY98 KALIMER shielding design

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Jae Woon; Kang, Chang Mu; Kim, Young Jin [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-01-01

    This report describes a preliminary evaluation of the shielding design of FY98 KALIMER. The KALIMER shielding design includes the Inner Fixed Shield of a stainless cylinder located inside the support barrel; the Radial PSDRS Shields which are three B{sub 4}C cylinders located outside the support barrel at core level; the Lower IHX shield of a cylindrical B{sub 4}C plate located above the flow guide; and Inner and Outer IHX shields of B{sub 4}C cylinders located inside and outside of the support barrel, respectively. The DORT3.1 two-dimensional transport code was used to evaluate the KALIMER shielding design. The reactor system was represented by four axial zones, each of which was modeled in the R-Z geometry. The KAFAX-F22 library was used in the analyses, which was generated from the JEF-2.2 of OECD/NEA files for LMR applications by KAERI. The performance of the KALIMER shielding design is compared against the shielding design criteria. The results indicate that the support barrel, upper grid plate, and other reactor structures meet the maximum neutron fluence and DPA limits established in the shielding design criteria. Activities of the air effluent in the PSDRS were also evaluated and are shown to satisfy the maximum permissible concentration (MPC) limits in 10 CFR Part 20. In the future, the validation of the DORT model by a detailed three dimensional calculation such as MCNP and the justification of the current shielding design limits are needed. (author). 13 refs., 23 figs., 31 tabs.

  19. Shielded scanning electron microscope for radioactive samples

    International Nuclear Information System (INIS)

    Crouse, R.S.; Parsley, W.B.

    1977-01-01

    A small commercial SEM had been successfully shielded for examining radioactive materials transferred directly from a remote handling facility. Relatively minor mechanical modifications were required to achieve excellent operation. Two inches of steel provide adequate shielding for most samples encountered. However, samples reading 75 rad/hr γ have been examined by adding extra shielding in the form of tungsten sample holders and external lead shadow shields. Some degradation of secondary electron imaging was seen but was adequately compensated for by changing operating conditions

  20. Photonic Bandgap (PBG) Shielding Technology

    Science.gov (United States)

    Bastin, Gary L.

    2007-01-01

    Photonic Bandgap (PBG) shielding technology is a new approach to designing electromagnetic shielding materials for mitigating Electromagnetic Interference (EM!) with small, light-weight shielding materials. It focuses on ground planes of printed wiring boards (PWBs), rather than on components. Modem PSG materials also are emerging based on planar materials, in place of earlier, bulkier, 3-dimensional PBG structures. Planar PBG designs especially show great promise in mitigating and suppressing EMI and crosstalk for aerospace designs, such as needed for NASA's Constellation Program, for returning humans to the moon and for use by our first human visitors traveling to and from Mars. Photonic Bandgap (PBG) materials are also known as artificial dielectrics, meta-materials, and photonic crystals. General PBG materials are fundamentally periodic slow-wave structures in I, 2, or 3 dimensions. By adjusting the choice of structure periodicities in terms of size and recurring structure spacings, multiple scatterings of surface waves can be created that act as a forbidden energy gap (i.e., a range of frequencies) over which nominally-conductive metallic conductors cease to be a conductor and become dielectrics. Equivalently, PBG materials can be regarded as giving rise to forbidden energy gaps in metals without chemical doping, analogous to electron bandgap properties that previously gave rise to the modem semiconductor industry 60 years ago. Electromagnetic waves cannot propagate over bandgap regions that are created with PBG materials, that is, over frequencies for which a bandgap is artificially created through introducing periodic defects

  1. Electron dose distributions caused by the contact-type metallic eye shield: Studies using Monte Carlo and pencil beam algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Sei-Kwon; Yoon, Jai-Woong; Hwang, Taejin; Park, Soah; Cheong, Kwang-Ho; Jin Han, Tae; Kim, Haeyoung; Lee, Me-Yeon; Ju Kim, Kyoung, E-mail: kjkim@hallym.or.kr; Bae, Hoonsik

    2015-10-01

    A metallic contact eye shield has sometimes been used for eyelid treatment, but dose distribution has never been reported for a patient case. This study aimed to show the shield-incorporated CT-based dose distribution using the Pinnacle system and Monte Carlo (MC) calculation for 3 patient cases. For the artifact-free CT scan, an acrylic shield machined as the same size as that of the tungsten shield was used. For the MC calculation, BEAMnrc and DOSXYZnrc were used for the 6-MeV electron beam of the Varian 21EX, in which information for the tungsten, stainless steel, and aluminum material for the eye shield was used. The same plan was generated on the Pinnacle system and both were compared. The use of the acrylic shield produced clear CT images, enabling delineation of the regions of interest, and yielded CT-based dose calculation for the metallic shield. Both the MC and the Pinnacle systems showed a similar dose distribution downstream of the eye shield, reflecting the blocking effect of the metallic eye shield. The major difference between the MC and the Pinnacle results was the target eyelid dose upstream of the shield such that the Pinnacle system underestimated the dose by 19 to 28% and 11 to 18% for the maximum and the mean doses, respectively. The pattern of dose difference between the MC and the Pinnacle systems was similar to that in the previous phantom study. In conclusion, the metallic eye shield was successfully incorporated into the CT-based planning, and the accurate dose calculation requires MC simulation.

  2. Gonad shielding in diagnostic radiology

    International Nuclear Information System (INIS)

    1975-06-01

    The use of gonad shielding is an important radiation protection technique, intended to reduce unnecessary x-ray exposure of the gonads of patients from diagnostic x-ray procedures. This pamphlet will provide physicians and radiologic technologists with information which will aid their appropriate use of gonad shielding

  3. SU-F-I-71: Fetal Protection During Fluoroscopy: To Shield Or Not to Shield?

    International Nuclear Information System (INIS)

    Joshi, S; Vanderhoek, M

    2016-01-01

    Purpose: Lead aprons are routinely used to shield the fetus from radiation during fluoroscopically guided interventions (FGI) involving pregnant patients. When placed in the primary beam, lead aprons often reduce image quality and increase fluoroscopic radiation output, which can adversely affect fetal dose. The purpose of this work is to identify an effective and practical method to reduce fetal dose without affecting image quality. Methods: A pregnant patient equivalent abdominal phantom is set on the table along with an image quality test object (CIRS model 903) representing patient anatomy of interest. An ion chamber is positioned at the x-ray beam entrance to the phantom, which is used to estimate the relative fetal dose. For three protective methods, image quality and fetal dose measurements are compared to baseline (no protection):1. Lead apron shielding the entire abdomen; 2. Lead apron shielding part of the abdomen, including the fetus; 3. Narrow collimation such that fetus is excluded from the primary beam. Results: With lead shielding the entire abdomen, the dose is reduced by 80% relative to baseline along with a drastic deterioration of image quality. With lead shielding only the fetus, the dose is reduced by 65% along with complete preservation of image quality, since the image quality test object is not shielded. However, narrow collimation results in 90% dose reduction and a slight improvement of image quality relative to baseline. Conclusion: The use of narrow collimation to protect the fetus during FGI is a simple and highly effective method that simultaneously reduces fetal dose and maintains sufficient image quality. Lead aprons are not as effective at fetal dose reduction, and if placed improperly, they can severely degrade image quality. Future work aims to investigate a wider variety of fluoroscopy systems to confirm these results across many different system geometries.

  4. SU-F-I-71: Fetal Protection During Fluoroscopy: To Shield Or Not to Shield?

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, S; Vanderhoek, M [Henry Ford Health System, Detroit, MI (United States)

    2016-06-15

    Purpose: Lead aprons are routinely used to shield the fetus from radiation during fluoroscopically guided interventions (FGI) involving pregnant patients. When placed in the primary beam, lead aprons often reduce image quality and increase fluoroscopic radiation output, which can adversely affect fetal dose. The purpose of this work is to identify an effective and practical method to reduce fetal dose without affecting image quality. Methods: A pregnant patient equivalent abdominal phantom is set on the table along with an image quality test object (CIRS model 903) representing patient anatomy of interest. An ion chamber is positioned at the x-ray beam entrance to the phantom, which is used to estimate the relative fetal dose. For three protective methods, image quality and fetal dose measurements are compared to baseline (no protection):1. Lead apron shielding the entire abdomen; 2. Lead apron shielding part of the abdomen, including the fetus; 3. Narrow collimation such that fetus is excluded from the primary beam. Results: With lead shielding the entire abdomen, the dose is reduced by 80% relative to baseline along with a drastic deterioration of image quality. With lead shielding only the fetus, the dose is reduced by 65% along with complete preservation of image quality, since the image quality test object is not shielded. However, narrow collimation results in 90% dose reduction and a slight improvement of image quality relative to baseline. Conclusion: The use of narrow collimation to protect the fetus during FGI is a simple and highly effective method that simultaneously reduces fetal dose and maintains sufficient image quality. Lead aprons are not as effective at fetal dose reduction, and if placed improperly, they can severely degrade image quality. Future work aims to investigate a wider variety of fluoroscopy systems to confirm these results across many different system geometries.

  5. SNF shipping cask shielding analysis

    International Nuclear Information System (INIS)

    Johnson, J.O.; Pace, J.V. III.

    1996-01-01

    The Waste Management and Remedial Action Division has planned a modification sequence for storage facility 7827 in the Solid Waste Storage Area (SWSA). The modification cycle is: (1) modify an empty caisson, (2) transfer the spent nuclear fuel (SNF) of an occupied caisson to a hot cell in building 3525 for inspection and possible repackaging, and (3) return the package to the modified caisson in the SWSA. Although the SNF to be moved is in the solid form, it has different levels of activity. Thus, the following 5 shipping casks will be available for the task: the Loop Transport Carrier, the In- Pile Loop LITR HB-2 Carrier, the 6.5-inch HRLEL Carrier, the HFIR Hot Scrap Carrier, and the 10-inch ORR Experiment Removal Shield Cask. This report describes the shielding tasks for the 5 casks: determination of shielding characteristics, any streaming avenues, estimation of thermal limits, and shielding calculational uncertainty for use in the transportation plan

  6. Neutron shielding for a {sup 252} Cf source

    Energy Technology Data Exchange (ETDEWEB)

    Vega C, H.R.; Manzanares A, E.; Hernandez D, V.M. [Unidades Academicas de Estudios Nucleares e Ingenieria Electrica, Universidad Autonoma de Zacatecas, C. Cipres 10, Fracc. La Penuela, 98068 Zacatecas (Mexico); Eduardo Gallego, Alfredo Lorente [Depto. de Ingenieria Nuclear, ETS Ingenieros Industriales, Universidad Politecnica de Madrid, C. Jose Gutierrez Abascal 2, 28006 Madrid (Spain)]. e-mail: fermineutron@yahoo.com

    2006-07-01

    To determine the neutron shielding features of water-extended polyester a Monte Carlo study was carried out. Materials with low atomic number are predominantly used for neutron shielding because these materials effectively attenuate neutrons, mainly through inelastic collisions and absorption reactions. During the selection of materials to design a neutron shield, prompt gamma production as well as radionuclide production induced by neutron activation must be considered. In this investigation the Monte Carlo method was used to evaluate the performance of a water-extended polyester shield designed for the transportation, storage, and use of a {sup 252}Cf isotopic neutron source. During calculations a detailed model for the {sup 252}Cf and the shield was utilized. To compare the shielding features of water extended polyester, the calculations were also made for the bare {sup 252}Cf in vacuum, air and the shield filled with water. For all cases the calculated neutron spectra was utilized to determine the ambient equivalent neutron dose at four sites around the shielding. In the case of water extended polyester and water shielding the calculations were extended to include the prompt gamma rays produced during neutron interactions, with this information the Kerma in air was calculated at the same locations where the ambient equivalent neutron dose was determined. (Author)

  7. EXPERIMENTAL EVALUATION OF THE THERMAL PERFORMANCE OF A WATER SHIELD FOR A SURFACE POWER REACTOR

    International Nuclear Information System (INIS)

    Reid, Robert S.; Pearson, J. Bosie; Stewart, Eric T.

    2007-01-01

    Water based reactor shielding is being investigated for use on initial lunar surface power systems. A water shield may lower overall cost (as compared to development cost for other materials) and simplify operations in the setup and handling. The thermal hydraulic performance of the shield is of significant interest. The mechanism for transferring heat through the shield is natural convection. Natural convection in a 100 kWt lunar surface reactor shield design is evaluated with 2 kW power input to the water in the Water Shield Testbed (WST) at the NASA Marshall Space Flight Center. The experimental data from the WST is used to validate a CFD model. Performance of the water shield on the lunar surface is then predicted with a CFD model anchored to test data. The experiment had a maximum water temperature of 75 C. The CFD model with 1/6-g predicts a maximum water temperature of 88 C with the same heat load and external boundary conditions. This difference in maximum temperature does not greatly affect the structural design of the shield, and demonstrates that it may be possible to use water for a lunar reactor shield.

  8. Experimental Evaluation of the Thermal Performance of a Water Shield for a Surface Power Reactor

    International Nuclear Information System (INIS)

    Pearson, J. Boise; Stewart, Eric T.; Reid, Robert S.

    2007-01-01

    Water based reactor shielding is being investigated for use on initial lunar surface power systems. A water shield may lower overall cost (as compared to development cost for other materials) and simplify operations in the setup and handling. The thermal hydraulic performance of the shield is of significant interest. The mechanism for transferring heat through the shield is natural convection. Natural convection in a 100 kWt lunar surface reactor shield design is evaluated with 2 kW power input to the water in the Water Shield Testbed (WST) at the NASA Marshall Space Flight Center. The experimental data from the WST is used to validate a CFD model. Performance of the water shield on the lunar surface is then predicted with a CFD model anchored to test data. The experiment had a maximum water temperature of 75 deg. C. The CFD model with 1/6-g predicts a maximum water temperature of 88 deg. C with the same heat load and external boundary conditions. This difference in maximum temperature does not greatly affect the structural design of the shield, and demonstrates that it may be possible to use water for a lunar reactor shield

  9. EXPERIMENTAL EVALUATION OF THE THERMAL PERFORMANCE OF A WATER SHIELD FOR A SURFACE POWER REACTOR

    Energy Technology Data Exchange (ETDEWEB)

    REID, ROBERT S. [Los Alamos National Laboratory; PEARSON, J. BOSIE [Los Alamos National Laboratory; STEWART, ERIC T. [Los Alamos National Laboratory

    2007-01-16

    Water based reactor shielding is being investigated for use on initial lunar surface power systems. A water shield may lower overall cost (as compared to development cost for other materials) and simplify operations in the setup and handling. The thermal hydraulic performance of the shield is of significant interest. The mechanism for transferring heat through the shield is natural convection. Natural convection in a 100 kWt lunar surface reactor shield design is evaluated with 2 kW power input to the water in the Water Shield Testbed (WST) at the NASA Marshall Space Flight Center. The experimental data from the WST is used to validate a CFD model. Performance of the water shield on the lunar surface is then predicted with a CFD model anchored to test data. The experiment had a maximum water temperature of 75 C. The CFD model with 1/6-g predicts a maximum water temperature of 88 C with the same heat load and external boundary conditions. This difference in maximum temperature does not greatly affect the structural design of the shield, and demonstrates that it may be possible to use water for a lunar reactor shield.

  10. Shield gas induced cracks during nanosecond-pulsed laser irradiation of Zr-based metallic glass

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Hu; Noguchi, Jun; Yan, Jiwang [Keio University, Department of Mechanical Engineering, Faculty of Science and Technology, Yokohama (Japan)

    2016-10-15

    Laser processing techniques have been given increasing attentions in the field of metallic glasses (MGs). In this work, effects of two kinds of shield gases, nitrogen and argon, on nanosecond-pulsed laser irradiation of Zr-based MG were comparatively investigated. Results showed that compared to argon gas, nitrogen gas remarkably promoted the formation of cracks during laser irradiation. Furthermore, crack formation in nitrogen gas was enhanced by increasing the peak laser power intensity or decreasing the laser scanning speed. X-ray diffraction and micro-Raman spectroscopy indicated that the reason for enhanced cracks in nitrogen gas was the formation of ZrN. (orig.)

  11. Shield gas induced cracks during nanosecond-pulsed laser irradiation of Zr-based metallic glass

    Science.gov (United States)

    Huang, Hu; Noguchi, Jun; Yan, Jiwang

    2016-10-01

    Laser processing techniques have been given increasing attentions in the field of metallic glasses (MGs). In this work, effects of two kinds of shield gases, nitrogen and argon, on nanosecond-pulsed laser irradiation of Zr-based MG were comparatively investigated. Results showed that compared to argon gas, nitrogen gas remarkably promoted the formation of cracks during laser irradiation. Furthermore, crack formation in nitrogen gas was enhanced by increasing the peak laser power intensity or decreasing the laser scanning speed. X-ray diffraction and micro-Raman spectroscopy indicated that the reason for enhanced cracks in nitrogen gas was the formation of ZrN.

  12. A perturbation technique for shield weight minimization

    International Nuclear Information System (INIS)

    Watkins, E.F.; Greenspan, E.

    1993-01-01

    The radiation shield optimization code SWAN (Ref. 1) was originally developed for minimizing the thickness of a shield that will meet a given dose (or another) constraint or for extremizing a performance parameter of interest (e.g., maximizing energy multiplication or minimizing dose) while maintaining the shield volume constraint. The SWAN optimization process proved to be highly effective (e.g., see Refs. 2, 3, and 4). The purpose of this work is to investigate the applicability of the SWAN methodology to problems in which the weight rather than the volume is the relevant shield characteristic. Such problems are encountered in shield design for space nuclear power systems. The investigation is carried out using SWAN with the coupled neutron-photon cross-section library FLUNG (Ref. 5)

  13. Mechanical design of the TIBER breeding shield

    Energy Technology Data Exchange (ETDEWEB)

    Rathke, J.; Deutsch, L. (Grumman Corp., Bethpage, NY (USA). Space Systems Div.)

    1989-04-01

    TIBER features a segmented shield assembly that provides the nuclear shielding for the superconducting toroidal field coils. In addition to its primary function, the shield also provides tritium breeding through the use of water coolant that contains 16 wt% dissolved lithium nitrate. Because the TIBER reactor need not provide electrical power, the coolant is maintained at low pressure (0.2 MPa) and low temperature (75/sup 0/C). The shield is made in several segments to facilitate assembly and allow for replacement of high heat flux components (divertor blades). The segments are designated as inboard, outboard, upper, lower, and divertor modules. In total, there are 96 separate modules in the machine, consisting of six different types. The design features of the different modules vary primarily depending on the thickness of the shield in a given location. The very thick outboard shield has a breeding zone in the inboard portion of the module, with a shielding zone behind it. The breeding zone consists of a stainless steel casing filled with beryllium spheres. The shielding zone consists of the same casing filled with steel spheres. Both of these zones have lithiated water circulated throughout to provide cooling and breeding. In zones with minimal thickness, tungsten alloys are used to achieve the required shielding. These alloys are incoprorated in subassemblies utilizing stainless steel casings surrounding blocks of tungsten heavy metal alloy. These are infiltrated with lead on final assembly to form a thermally continuous panel. Several of these panels are then assembled into an outer stainless steel case to form an inboard module. These modules also use the lithiated coolant. The details of the design are presented and discussed. (orig.).

  14. Using glass as a shielding material

    International Nuclear Information System (INIS)

    Yousef, S.

    2002-04-01

    Different theoretical and technological concepts and problems in using glass as a shielding material was discussed, some primarily designs for different types of radiation shielding windows were illustrated. (author)

  15. Using glass as a shielding material

    International Nuclear Information System (INIS)

    Yousef, S.

    2003-01-01

    Different theoretical and technological concepts and problems in using glass as a shielding material was discussed, some primarily designs for different types of radiation shielding windows were illustrated. (author)

  16. Shielding performances analysis for the IFMIF test facility based on high-fidelity Monte Carlo neutronic calculations

    Energy Technology Data Exchange (ETDEWEB)

    Kondo, Keitaro, E-mail: kondo.keitaro@jaea.go.jp; Arbeiter, Frederik; Fischer, Ulrich; Lu, Lei; Qiu, Yuefeng; Tian, Kuo

    2015-10-15

    Highlights: • A detailed geometry model with pipe penetrations and gaps was prepared for the IFMIF test cell. • The neutron streaming effect due to gaps and pipes with shielding plugs was investigated. • The present analysis revealed that the streaming effect can be mitigated by some counter measures. • Occupational workers can access to the room above the test cell during operation. - Abstract: The IFMIF Test Cell (TC) design was developed and optimized in the EVEDA phase, and finally the reference TC design was proposed. The present study is devoted to further investigations of open issues on the reference TC design. In order to examine the neutron streaming effect caused by pipe penetrations and gaps around removable shielding plugs, a new geometry model for neutronic analyses has been prepared directly from engineering CAD data by utilizing the McCad conversion software. All removable shielding plugs are separately described in the model and a detailed description of pipes was incorporated into the model. The calculation result suggests that the streaming effect is mitigated if the pipe penetration is designed appropriately, while the gaps around the shielding plugs above the TC have large impact on the radiation dose in the access cell. The concept of the reference TC design has been basically validated from the neutronics point of view, although the streaming effect should be compensated by the shielding capability of the test cell cover plate so that occupational workers can access to the access cell during operation.

  17. Shielding performances analysis for the IFMIF test facility based on high-fidelity Monte Carlo neutronic calculations

    International Nuclear Information System (INIS)

    Kondo, Keitaro; Arbeiter, Frederik; Fischer, Ulrich; Lu, Lei; Qiu, Yuefeng; Tian, Kuo

    2015-01-01

    Highlights: • A detailed geometry model with pipe penetrations and gaps was prepared for the IFMIF test cell. • The neutron streaming effect due to gaps and pipes with shielding plugs was investigated. • The present analysis revealed that the streaming effect can be mitigated by some counter measures. • Occupational workers can access to the room above the test cell during operation. - Abstract: The IFMIF Test Cell (TC) design was developed and optimized in the EVEDA phase, and finally the reference TC design was proposed. The present study is devoted to further investigations of open issues on the reference TC design. In order to examine the neutron streaming effect caused by pipe penetrations and gaps around removable shielding plugs, a new geometry model for neutronic analyses has been prepared directly from engineering CAD data by utilizing the McCad conversion software. All removable shielding plugs are separately described in the model and a detailed description of pipes was incorporated into the model. The calculation result suggests that the streaming effect is mitigated if the pipe penetration is designed appropriately, while the gaps around the shielding plugs above the TC have large impact on the radiation dose in the access cell. The concept of the reference TC design has been basically validated from the neutronics point of view, although the streaming effect should be compensated by the shielding capability of the test cell cover plate so that occupational workers can access to the access cell during operation.

  18. CSI-EPT in Presence of RF-Shield for MR-Coils.

    Science.gov (United States)

    Arduino, Alessandro; Zilberti, Luca; Chiampi, Mario; Bottauscio, Oriano

    2017-07-01

    Contrast source inversion electric properties tomography (CSI-EPT) is a recently developed technique for the electric properties tomography that recovers the electric properties distribution starting from measurements performed by magnetic resonance imaging scanners. This method is an optimal control approach based on the contrast source inversion technique, which distinguishes itself from other electric properties tomography techniques for its capability to recover also the local specific absorption rate distribution, essential for online dosimetry. Up to now, CSI-EPT has only been described in terms of integral equations, limiting its applicability to homogeneous unbounded background. In order to extend the method to the presence of a shield in the domain-as in the recurring case of shielded radio frequency coils-a more general formulation of CSI-EPT, based on a functional viewpoint, is introduced here. Two different implementations of CSI-EPT are proposed for a 2-D transverse magnetic model problem, one dealing with an unbounded domain and one considering the presence of a perfectly conductive shield. The two implementations are applied on the same virtual measurements obtained by numerically simulating a shielded radio frequency coil. The results are compared in terms of both electric properties recovery and local specific absorption rate estimate, in order to investigate the requirement of an accurate modeling of the underlying physical problem.

  19. Development of neutron shielding concrete containing iron content materials

    Science.gov (United States)

    Sariyer, Demet; Küçer, Rahmi

    2018-02-01

    Concrete is one of the most important construction materials which widely used as a neutron shielding. Neutron shield is obtained of interaction with matter depends on neutron energy and the density of the shielding material. Shielding properties of concrete could be improved by changing its composition and density. High density materials such as iron or high atomic number elements are added to concrete to increase the radiation resistance property. In this study, shielding properties of concrete were investigated by adding iron, FeB, Fe2B, stainless - steel at different ratios into concrete. Neutron dose distributions and shield design was obtained by using FLUKA Monte Carlo code. The determined shield thicknesses vary depending on the densities of the mixture formed by the additional material and ratio. It is seen that a combination of iron rich materials is enhanced the neutron shielding of capabilities of concrete. Also, the thicknesses of shield are reduced.

  20. Recent Improvements in the SHIELD-HIT Code

    DEFF Research Database (Denmark)

    Hansen, David Christoffer; Lühr, Armin Christian; Herrmann, Rochus

    2012-01-01

    Purpose: The SHIELD-HIT Monte Carlo particle transport code has previously been used to study a wide range of problems for heavy-ion treatment and has been benchmarked extensively against other Monte Carlo codes and experimental data. Here, an improved version of SHIELD-HIT is developed concentra......Purpose: The SHIELD-HIT Monte Carlo particle transport code has previously been used to study a wide range of problems for heavy-ion treatment and has been benchmarked extensively against other Monte Carlo codes and experimental data. Here, an improved version of SHIELD-HIT is developed...

  1. RADSHI: shielding calculation program for different geometries sources

    International Nuclear Information System (INIS)

    Gelen, A.; Alvarez, I.; Lopez, H.; Manso, M.

    1996-01-01

    A computer code written in pascal language for IBM/Pc is described. The program calculates the optimum thickness of slab shield for different geometries sources. The Point Kernel Method is employed, which enables the obtention of the ionizing radiation flux density. The calculation takes into account the possibility of self-absorption in the source. The air kerma rate for gamma radiation is determined, and with the concept of attenuation length through the equivalent attenuation length the shield is obtained. The scattering and the exponential attenuation inside the shield material is considered in the program. The shield materials can be: concrete, water, iron or lead. It also calculates the shield for point isotropic neutron source, using as shield materials paraffin, concrete or water. (authors). 13 refs

  2. SHIELDS Final Technical Report

    Energy Technology Data Exchange (ETDEWEB)

    Jordanova, Vania Koleva [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-10-03

    Predicting variations in the near-Earth space environment that can lead to spacecraft damage and failure, i.e. “space weather”, remains a big space physics challenge. A new capability was developed at Los Alamos National Laboratory (LANL) to understand, model, and predict Space Hazards Induced near Earth by Large Dynamic Storms, the SHIELDS framework. This framework simulates the dynamics of the Surface Charging Environment (SCE), the hot (keV) electrons representing the source and seed populations for the radiation belts, on both macro- and micro-scale. In addition to using physics-based models (like RAM-SCB, BATS-R-US, and iPIC3D), new data assimilation techniques employing data from LANL instruments on the Van Allen Probes and geosynchronous satellites were developed. An order of magnitude improvement in the accuracy in the simulation of the spacecraft surface charging environment was thus obtained. SHIELDS also includes a post-processing tool designed to calculate the surface charging for specific spacecraft geometry using the Curvilinear Particle-In-Cell (CPIC) code and to evaluate anomalies' relation to SCE dynamics. Such diagnostics is critically important when performing forensic analyses of space-system failures.

  3. Micrometeoroid and Orbital Debris (MMOD) Shield Ballistic Limit Analysis Program

    Science.gov (United States)

    Ryan, Shannon

    2013-01-01

    This software implements penetration limit equations for common micrometeoroid and orbital debris (MMOD) shield configurations, windows, and thermal protection systems. Allowable MMOD risk is formulated in terms of the probability of penetration (PNP) of the spacecraft pressure hull. For calculating the risk, spacecraft geometry models, mission profiles, debris environment models, and penetration limit equations for installed shielding configurations are required. Risk assessment software such as NASA's BUMPERII is used to calculate mission PNP; however, they are unsuitable for use in shield design and preliminary analysis studies. The software defines a single equation for the design and performance evaluation of common MMOD shielding configurations, windows, and thermal protection systems, along with a description of their validity range and guidelines for their application. Recommendations are based on preliminary reviews of fundamental assumptions, and accuracy in predicting experimental impact test results. The software is programmed in Visual Basic for Applications for installation as a simple add-in for Microsoft Excel. The user is directed to a graphical user interface (GUI) that requires user inputs and provides solutions directly in Microsoft Excel workbooks.

  4. Preparation and properties of the fast-curing γ-ray-shielding materials based on polyurethane

    Energy Technology Data Exchange (ETDEWEB)

    Ni, Minxuan; Tang, Xiao Bin; Chai, Hao; Zhang, Yun; Chen, Tuo; Chen, Da [Dept. of Nuclear Science and Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing (China)

    2016-12-15

    In this study, fast-curing shielding materials were prepared with a two-component polyurethane matrix and a filler material of PbO through a one-step, laboratory-scale method. With an increase in the filler content, viscosity increased. However, the two components showed a small difference. Curing time decreased as the filler content increased. The minimum tack-free time of 27 s was obtained at a filler content of 70 wt%. Tensile strength and compressive strength initially increased and then decreased as the filler content increased. Even when the filler content reached 60 wt%, mechanical properties were still greater than those of the matrix. Cohesional strength decreased as the filler content increased. However, cohesional strength was still greater than 100 kPa at a filler content of 60 wt%. The γ-ray-shielding properties increased with the increase in the filler content, and composite thickness could be increased to improve the shielding performance when the energy of γ-rays was high. When the filler content was 60 wt%, the composite showed excellent comprehensive properties.

  5. Measurements and Monte-Carlo simulations of the particle self-shielding effect of B4C grains in neutron shielding concrete

    Science.gov (United States)

    DiJulio, D. D.; Cooper-Jensen, C. P.; Llamas-Jansa, I.; Kazi, S.; Bentley, P. M.

    2018-06-01

    A combined measurement and Monte-Carlo simulation study was carried out in order to characterize the particle self-shielding effect of B4C grains in neutron shielding concrete. Several batches of a specialized neutron shielding concrete, with varying B4C grain sizes, were exposed to a 2 Å neutron beam at the R2D2 test beamline at the Institute for Energy Technology located in Kjeller, Norway. The direct and scattered neutrons were detected with a neutron detector placed behind the concrete blocks and the results were compared to Geant4 simulations. The particle self-shielding effect was included in the Geant4 simulations by calculating effective neutron cross-sections during the Monte-Carlo simulation process. It is shown that this method well reproduces the measured results. Our results show that shielding calculations for low-energy neutrons using such materials would lead to an underestimate of the shielding required for a certain design scenario if the particle self-shielding effect is not included in the calculations.

  6. 21 CFR 886.4750 - Ophthalmic eye shield.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4750 Ophthalmic eye shield. (a) Identification. An ophthalmic eye shield is a device that consists of a plastic or aluminum eye covering intended to... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic eye shield. 886.4750 Section 886.4750...

  7. MFTF-α + T shield design

    International Nuclear Information System (INIS)

    Gohar, Y.

    1985-01-01

    MFTF-α+T is a DT upgrade option of the Tandem Mirror Fusion Test Facility (MFTF-B) to study better plasma performance, and test tritium breeding blankets in an actual fusion reactor environment. The central cell insert, designated DT axicell, has a 2-MW/m 2 neutron wall loading at the first wall for blanket testing. This upgrade is completely shielded to protect the reactor components, the workers, and the general public from the radiation environment during operation and after shutdown. The shield design for this upgrade is the subject of this paper including the design criteria and the tradeoff studies to reduce the shield cost

  8. Monte Carlo-based development of a shield and total background estimation for the COBRA experiment

    International Nuclear Information System (INIS)

    Heidrich, Nadine

    2014-11-01

    The COBRA experiment aims for the measurement of the neutrinoless double beta decay and thus for the determination the effective Majorana mass of the neutrino. To be competitive with other next-generation experiments the background rate has to be in the order of 10 -3 counts/kg/keV/yr, which is a challenging criterion. This thesis deals with the development of a shield design and the calculation of the expected total background rate for the large scale COBRA experiment containing 13824 6 cm 3 CdZnTe detectors. For the development of a shield single-layer and multi-layer shields were investigated and a shield design was optimized concerning high-energy muon-induced neutrons. As the best design the combination of 10 cm boron doped polyethylene as outermost layer, 20 cm lead and 10 cm copper as innermost layer were determined. It showed the best performance regarding neutron attenuation as well as (n, γ) self-shielding effects leading to a negligible background rate of less than 2.10 -6 counts/kg/keV/yr. Additionally. the shield with a thickness of 40 cm is compact and costeffective. In the next step the expected total background rate was computed taking into account individual setup parts and various background sources including natural and man-made radioactivity, cosmic ray-induced background and thermal neutrons. Furthermore, a comparison of measured data from the COBRA demonstrator setup with Monte Carlo data was used to calculate reliable contamination levels of the single setup parts. The calculation was performed conservatively to prevent an underestimation. In addition, the contribution to the total background rate regarding the individual detector parts and background sources was investigated. The main portion arise from the Delrin support structure, the Glyptal lacquer followed by the circuit board of the high voltage supply. Most background events originate from particles with a quantity of 99 % in total. Regarding surface events a contribution of 26

  9. Monte Carlo-based development of a shield and total background estimation for the COBRA experiment

    Energy Technology Data Exchange (ETDEWEB)

    Heidrich, Nadine

    2014-11-15

    The COBRA experiment aims for the measurement of the neutrinoless double beta decay and thus for the determination the effective Majorana mass of the neutrino. To be competitive with other next-generation experiments the background rate has to be in the order of 10{sup -3} counts/kg/keV/yr, which is a challenging criterion. This thesis deals with the development of a shield design and the calculation of the expected total background rate for the large scale COBRA experiment containing 13824 6 cm{sup 3} CdZnTe detectors. For the development of a shield single-layer and multi-layer shields were investigated and a shield design was optimized concerning high-energy muon-induced neutrons. As the best design the combination of 10 cm boron doped polyethylene as outermost layer, 20 cm lead and 10 cm copper as innermost layer were determined. It showed the best performance regarding neutron attenuation as well as (n, γ) self-shielding effects leading to a negligible background rate of less than 2.10{sup -6} counts/kg/keV/yr. Additionally. the shield with a thickness of 40 cm is compact and costeffective. In the next step the expected total background rate was computed taking into account individual setup parts and various background sources including natural and man-made radioactivity, cosmic ray-induced background and thermal neutrons. Furthermore, a comparison of measured data from the COBRA demonstrator setup with Monte Carlo data was used to calculate reliable contamination levels of the single setup parts. The calculation was performed conservatively to prevent an underestimation. In addition, the contribution to the total background rate regarding the individual detector parts and background sources was investigated. The main portion arise from the Delrin support structure, the Glyptal lacquer followed by the circuit board of the high voltage supply. Most background events originate from particles with a quantity of 99 % in total. Regarding surface events a

  10. Design report for shielded glove box

    International Nuclear Information System (INIS)

    Ku, J. H.; Lee, J. C.; Seo, K. S.; Bang, K. S.; Lee, D. W.; Kim, J. H.; Min, D. K.; Park, S. W.

    1999-05-01

    For the examination of spent fuels and high radioactive specimens using a specially equipped scanning electron microscope, a shielded glove box was designed and constructed at PIE facility of KAERI. This glove box consisted of shielding walls, containment box, lead glasses, manipulators, gloves, ventilation systems, doors, hot-cell specimen cask adapter, etc. It was emphasized that both the easy operation and radiation safety are important factors in the shielded glove box were installed also considered as a important factor to build the basic concept of the assembling. Two sliding doors and one hinge-type door were installed for the easy installation, operation and maintenance of scanning electron microscope. Containment box which confines the radioactive material into the box consisted of reinforced transparent glasses, aluminum frames and stainless steel plate liner. Therefore everything beyond the containment box can be seen through the lead glass which installed at the front shielding wall. All shielding walls and doors were introduced separately into the room and assembled by bolting. (author). 3 refs., 5 tabs., 18 figs

  11. Neutral and plasma shielding model for pellet ablation

    International Nuclear Information System (INIS)

    Houlberg, W.A.; Milora, S.L.; Attenberger, S.E.

    1987-10-01

    The neutral gas shielding model for ablation of frozen hydrogenic pellets is extended to include the effects of an initial Maxwelliam distribution of incident electron energies; a cold plasma shield outside the neutral shield and extended along the magnetic field; energetic neutral beam ions and alpha particles; and self-limiting electron ablation in the collisionless plasma limit. Including the full electron distribution increases ablation, but adding the cold ionized shield reduces ablation; the net effect is a modest reduction in pellet penetration compared with the monoenergetic electron neutral shielding model with no plasma shield. Unlike electrons, fast ions can enter the neutral shield directly without passing through the cold ionized shield because their gyro-orbits are typically larger than the diameter of the cold plasma tube. Fast alpha particles should not enhance the ablation rate unless their population exceeds that expected from local classical thermalization. Fast beam ions, however, may enhance ablation in the plasma periphery if their population is high enough. Self-limiting ablation in the collisionless limit leads to a temporary distortion of the original plasma electron Maxwellian distribution function through preferential depopulation of the higher-energy electrons. 23 refs., 9 figs

  12. Transparent Metal-Salt-Filled Polymeric Radiation Shields

    Science.gov (United States)

    Edwards, David; Lennhoff, John; Harris, George

    2003-01-01

    "COR-RA" (colorless atomic oxygen resistant -- radiation shield) is the name of a transparent polymeric material filled with x-ray-absorbing salts of lead, bismuth, cesium, and thorium. COR-RA is suitable for use in shielding personnel against bremsstrahlung radiation from electron-beam welding and industrial and medical x-ray equipment. In comparison with lead-foil and leaded-glass shields that give equivalent protection against x-rays (see table), COR-RA shields are mechanically more durable. COR-RA absorbs not only x-rays but also neutrons and rays without adverse effects on optical or mechanical performance. The formulation of COR-RA with the most favorable mechanical-durability and optical properties contains 22 weight percent of bismuth to absorb x-rays, plus 45 atomic percent hydrogen for shielding against neutrons.

  13. Effect of neutrons scattered from boundary of neutron field on shielding experiment

    International Nuclear Information System (INIS)

    Ogawa, Tatsuhiko; Abe, Takuya; Kosako, Toshiso; Iimoto, Takeshi

    2009-01-01

    Neutron shielding experiment with 49 cm-thick ordinary concrete was carried out at the reactor 'Yayoi' The University of Tokyo. System of this experiment is enclosed by heavy concrete where neutrons backscattered from heavy concrete likely affected neutron flux on the back surface of shielding concrete. Reaction rate of 197 Au(n, γ), cadmium covered 197 Au(n, γ) and 115 In(n, n') in the shielding concrete was measured using foil activation method. Neutron transport calculation was carried out in order to simulate reaction rate by calculating neutron spectra and convoluting with neutron capture cross-section in neutron shielding concrete. Comparison was made between calculated reaction rate and experimental one, and almost satisfactory agreement was found except for the back surface of shielding. To compose adequate simulation model, description of heavy concrete behind the shielding was thought to be of importance. For example, disregarding neutrons backscattered from heavy concrete, calculation underestimated reaction rate by the factor of 10. In another example, assuming that chemical composition of heavy concrete is equal to the composition adopted from a literature, the reaction rate was overestimated by factor of 5. By making the composition of heavy concrete equal to that based on facility design, overestimation was found to be the factor of 2. Therefore, adequate description of chemical composition of heavy concrete is found to be of importance in order to simulate neutron induced reaction rate on the back surface of neutron shielding concrete in shielding experiment performed in a system enclosed by heavy concrete. (author)

  14. Background components of Ge(Li) and GeHP-detectors in the passive shield

    International Nuclear Information System (INIS)

    Buraeva, E.A.; Davydov, M.G.; Zorina, L.V.; Stasov, V.V.

    2007-01-01

    The gamma-spectrometer Ge(Li)- and the extra pure Ge-detector background components in a specially designed passive shield were subjected to investigation in the land-based laboratory in 1996-2006. The measurement time period varied from 45 up to 240 hours. The detector background is caused by the radionuclides in the shield material, in the shield cells and in the detector materials. The prominence was given to the study of the revealed time dependence of 222 Rn daughter product background including '2 10 Pb 46.5 keV peak [ru

  15. Nanostructured composite layers for electromagnetic shielding in the GHz frequency range

    Energy Technology Data Exchange (ETDEWEB)

    Suchea, M. [Center of Materials Technology and Photonics, School of Engineering, Technological Educational Institute of Crete, Heraklion (Greece); Chemistry and Physics, “Al.I. Cuza” University of Iasi, Iasi (Romania); Tudose, I.V. [Chemistry and Physics, “Al.I. Cuza” University of Iasi, Iasi (Romania); Center of Materials Technology and Photonics, School of Engineering, Technological Educational Institute of Crete, Heraklion (Greece); Tzagkarakis, G. [Center of Materials Technology and Photonics, School of Engineering, Technological Educational Institute of Crete, Heraklion (Greece); Electrical Engineering Department, School of Engineering, Technological Educational Institute of Crete, Heraklion (Greece); Kenanakis, G. [Center of Materials Technology and Photonics, School of Engineering, Technological Educational Institute of Crete, Heraklion (Greece); Institute of Electronic Structure & Laser (IESL), Foundation for Research and Technology (FORTH) Hellas, Heraklion (Greece); Katharakis, M. [Center of Materials Technology and Photonics, School of Engineering, Technological Educational Institute of Crete, Heraklion (Greece); Drakakis, E. [Electrical Engineering Department, School of Engineering, Technological Educational Institute of Crete, Heraklion (Greece); Koudoumas, E., E-mail: koudoumas@staff.teicrete.gr [Center of Materials Technology and Photonics, School of Engineering, Technological Educational Institute of Crete, Heraklion (Greece); Electrical Engineering Department, School of Engineering, Technological Educational Institute of Crete, Heraklion (Greece)

    2015-10-15

    Graphical abstract: - Highlights: • Paint-like nanocomposite layers consisting of graphene nanoplatelets, PANI:HCl and PEDOT:PSS present very effective attenuation of electromagnetic radiation in the frequency range 4–20 GHz. • The shielding performance is based mostly on the graphene nanoplatelets and supported by PANI:HCl. In contrast, PEDOT:PSS plays mainly the role of the binder. • Increasing resistivity was observed to reduce the shielding effect, while increasing thickness to favor it. - Abstract: We report on preliminary results regarding the applicability of nanostructured composite layers for electromagnetic shielding in the frequency range of 4–20 GHz. Various combinations of materials were employed including poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT:PSS), polyaniline, graphene nanoplatelets, carbon nanotubes, Cu nanoparticles and Poly(vinyl alcohol). As shown, paint-like nanocomposite layers consisting of graphene nanoplatelets, polyaniline PEDOT:PSS and Poly(vinyl alcohol) can offer quite effective electromagnetic shielding, similar or even better than that of commercial products, the response strongly depending on their thickness and resistivity.

  16. Laboratory tests on neutron shields for gamma-ray detectors in space

    CERN Document Server

    Hong, J; Hailey, C J

    2000-01-01

    Shields capable of suppressing neutron-induced background in new classes of gamma-ray detectors such as CdZnTe are becoming important for a variety of reasons. These include a high cross section for neutron interactions in new classes of detector materials as well as the inefficient vetoing of neutron-induced background in conventional active shields. We have previously demonstrated through Monte-Carlo simulations how our new approach, supershields, is superior to the monolithic, bi-atomic neutron shields which have been developed in the past. We report here on the first prototype models for supershields based on boron and hydrogen. We verify the performance of these supershields through laboratory experiments. These experimental results, as well as measurements of conventional monolithic neutron shields, are shown to be consistent with Monte-Carlo simulations. We discuss the implications of this experiment for designs of supershields in general and their application to future hard X-ray/gamma-ray experiments...

  17. Nanostructured composite layers for electromagnetic shielding in the GHz frequency range

    International Nuclear Information System (INIS)

    Suchea, M.; Tudose, I.V.; Tzagkarakis, G.; Kenanakis, G.; Katharakis, M.; Drakakis, E.; Koudoumas, E.

    2015-01-01

    Graphical abstract: - Highlights: • Paint-like nanocomposite layers consisting of graphene nanoplatelets, PANI:HCl and PEDOT:PSS present very effective attenuation of electromagnetic radiation in the frequency range 4–20 GHz. • The shielding performance is based mostly on the graphene nanoplatelets and supported by PANI:HCl. In contrast, PEDOT:PSS plays mainly the role of the binder. • Increasing resistivity was observed to reduce the shielding effect, while increasing thickness to favor it. - Abstract: We report on preliminary results regarding the applicability of nanostructured composite layers for electromagnetic shielding in the frequency range of 4–20 GHz. Various combinations of materials were employed including poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT:PSS), polyaniline, graphene nanoplatelets, carbon nanotubes, Cu nanoparticles and Poly(vinyl alcohol). As shown, paint-like nanocomposite layers consisting of graphene nanoplatelets, polyaniline PEDOT:PSS and Poly(vinyl alcohol) can offer quite effective electromagnetic shielding, similar or even better than that of commercial products, the response strongly depending on their thickness and resistivity.

  18. Program for photon shielding calculations. Examination of approximations on irradiation geometries

    International Nuclear Information System (INIS)

    Isozumi, Yasuhito; Ishizuka, Fumihiko; Miyatake, Hideo; Kato, Takahisa; Tosaki, Mitsuo

    2004-01-01

    Penetration factors and related numerical data in 'Manual of Practical Shield Calculation of Radiation Facilities (2000)', which correspond to the irradiation geometries of point isotropic source in infinite thick material (PI), point isotropic source in finite thick material (PF) and vertical incident to finite thick material (VF), have been carefully examined. The shield calculation based on the PI geometry is usually performed with effective dose penetration factors of radioisotopes given in the 'manual'. The present work cleary shows that such a calculation may lead to an overestimate more than twice larger, especially for thick shield of concrete and water. Employing the numerical data in the 'manual', we have fabricated a simple computer program for the estimation of penetration factors and effective doses of radioisotopes in the different irradiation geometries, i.e., PI, PF and VF. The program is also available to calculate the effective dose from a set of radioisotopes in the different positions, which is necessary for the γ-ray shielding of radioisotope facilities. (author)

  19. Shielding requirements for particle bed propulsion systems

    Science.gov (United States)

    Gruneisen, S. J.

    1991-06-01

    Nuclear Thermal Propulsion systems present unique challenges in reliability and safety. Due to the radiation incident upon all components of the propulsion system, shielding must be used to keep nuclear heating in the materials within limits; in addition, electronic control systems must be protected. This report analyzes the nuclear heating due to the radiation and the shielding required to meet the established criteria while also minimizing the shield mass. Heating rates were determined in a 2000 MWt Particle Bed Reactor (PBR) system for all materials in the interstage region, between the reactor vessel and the propellant tank, with special emphasis on meeting the silicon dose criteria. Using a Lithium Hydride/Tungsten shield, the optimum shield design was found to be: 50 cm LiH/2 cm W on the axial reflector in the reactor vessel and 50 cm LiH/2 cm W in a collar extension of the inside shield outside of the pressure vessel. Within these parameters, the radiation doses in all of the components in the interstage and lower tank regions would be within acceptable limits for mission requirements.

  20. Potential of Nanocellulose Composite for Electromagnetic Shielding

    Directory of Open Access Journals (Sweden)

    Nabila Yah Nurul Fatihah

    2017-01-01

    Full Text Available Nowadays, most people rely on the electronic devices for work, communicating with friends and family, school and personal enjoyment. As a result, more new equipment or devices operates in higher frequency were rapidly developed to accommodate the consumers need. However, the demand of using wireless technology and higher frequency in new devices also brings the need to shield the unwanted electromagnetic signals from those devices for both proper operation and human health concerns. This paper highlights the potential of nanocellulose for electromagnetic shielding using the organic environmental nanocellulose composite materials. In addition, the theory of electromagnetic shielding and recent development of green and organic material in electromagnetic shielding application has also been reviewed in this paper. The use of the natural fibers which is nanocelllose instead of traditional reinforcement materials provides several advantages including the natural fibers are renewable, abundant and low cost. Furthermore, added with other advantages such as lightweight and high electromagnetic shielding ability, nanocellulose has a great potential as an alternative material for electromagnetic shielding application.

  1. Electron dose distributions caused by the contact-type metallic eye shield: Studies using Monte Carlo and pencil beam algorithms.

    Science.gov (United States)

    Kang, Sei-Kwon; Yoon, Jai-Woong; Hwang, Taejin; Park, Soah; Cheong, Kwang-Ho; Han, Tae Jin; Kim, Haeyoung; Lee, Me-Yeon; Kim, Kyoung Ju; Bae, Hoonsik

    2015-01-01

    A metallic contact eye shield has sometimes been used for eyelid treatment, but dose distribution has never been reported for a patient case. This study aimed to show the shield-incorporated CT-based dose distribution using the Pinnacle system and Monte Carlo (MC) calculation for 3 patient cases. For the artifact-free CT scan, an acrylic shield machined as the same size as that of the tungsten shield was used. For the MC calculation, BEAMnrc and DOSXYZnrc were used for the 6-MeV electron beam of the Varian 21EX, in which information for the tungsten, stainless steel, and aluminum material for the eye shield was used. The same plan was generated on the Pinnacle system and both were compared. The use of the acrylic shield produced clear CT images, enabling delineation of the regions of interest, and yielded CT-based dose calculation for the metallic shield. Both the MC and the Pinnacle systems showed a similar dose distribution downstream of the eye shield, reflecting the blocking effect of the metallic eye shield. The major difference between the MC and the Pinnacle results was the target eyelid dose upstream of the shield such that the Pinnacle system underestimated the dose by 19 to 28% and 11 to 18% for the maximum and the mean doses, respectively. The pattern of dose difference between the MC and the Pinnacle systems was similar to that in the previous phantom study. In conclusion, the metallic eye shield was successfully incorporated into the CT-based planning, and the accurate dose calculation requires MC simulation. Copyright © 2015 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  2. Multi-objective optimization design method of radiation shielding

    International Nuclear Information System (INIS)

    Yang Shouhai; Wang Weijin; Lu Daogang; Chen Yixue

    2012-01-01

    Due to the shielding design goals of diversification and uncertain process of many factors, it is necessary to develop an optimization design method of intelligent shielding by which the shielding scheme selection will be achieved automatically and the uncertainties of human impact will be reduced. For economical feasibility to achieve a radiation shielding design for automation, the multi-objective genetic algorithm optimization of screening code which combines the genetic algorithm and discrete-ordinate method was developed to minimize the costs, size, weight, and so on. This work has some practical significance for gaining the optimization design of shielding. (authors)

  3. Estimation of temperature distribution in a reactor shield

    International Nuclear Information System (INIS)

    Agarwal, R.A.; Goverdhan, P.; Gupta, S.K.

    1989-01-01

    Shielding is provided in a nuclear reactor to absorb the radiations emanating from the core. The energy of these radiations appear in the form of heat. Concrete which is commonly used as a shielding material in nuclear power plants must be able to withstand the temperatures and temperature gradients appearing in the shield due to this heat. High temperatures lead to dehydration of the concrete and in turn reduce the shielding effectiveness of the material. Adequate cooling needs to be provided in these shields in order to limit the maximum temperature. This paper describes a method to estimate steady state and transient temperature distribution in reactor shields. The results due to loss of coolant in the coolant tubes have been studied and presented in the paper. (author). 5 figs

  4. Supplemental shielding of BMIT SOE-1 at the Canadian Light Source

    International Nuclear Information System (INIS)

    Bassey, Bassey; Abueidda, Abdallah; Cubbon, Grant; Street, Darin; Sabbir Ahmed, Asm; Wysokinski, Tomasz W.; Belev, George; Chapman, Dean

    2014-01-01

    High field superconducting wiggler beamlines present shielding challenges due to the high critical energy of the synchrotron spectrum. An unexpected, but predictable, weakness in the secondary optical enclosure (SOE-1) was discovered on the BioMedical Imaging and Therapy (BMIT) insertion device (ID) beamline 05ID-2 at the Canadian Light Source (CLS). SOE-1 is a monochromatic beam hutch; the beam in it is supplied by three monochromators housed in an upstream primary optical enclosure (POE-3). The initial shielding of SOE-1 was based on a shielding calculation against target scattered and direct monochromatic (fundamental and harmonics) beams from the monochromators in POE-3. During a radiation survey of the hutch, radiation above the expected level was measured at the downstream end of SOE-1. This increment in radiation level is attributed to scattered white beam into SOE-1 by a K-Edge subtraction (KES) monochromator's crystal (a single crystal monochromator) in POE-3. Though this is peculiar to the BMIT beamline 05ID-2, it may not be uncommon for other beamlines that use single crystal monochromators. Calculations of the level of expected leakage radiation due to the scattered white beam arriving on the downstream wall of the SOE-1 are presented, as well as the supplemental shielding that will reduce the leakage to less than 1 μSv/h as required at the CLS. Also presented are the installed supplemental shielding, and a comparison of the calculations and measurements of the dose rates on the back wall of SOE-1 End Wall, before and after installation of the supplemental shielding. - Highlights: • We discovered an unexpected weakness in the shielding of BMIT SOE-1 End Wall. • We predicted the source of the weakness-scattering of white beam into SOE-1. • White beam scattered into SOE-1 by the crystal of a single crystal monochromator. • We calculated and installed the required supplemental shielding. • With the installed supplemental shielding, we have

  5. Nuclear shields

    International Nuclear Information System (INIS)

    Linares, R.C.; Nienart, L.F.; Toelcke, G.A.

    1976-01-01

    A process is described for preparing melt-processable nuclear shielding compositions from chloro-fluoro substituted ethylene polymers, particularly PCTFE and E-CTFE, containing 1 to 75 percent by weight of a gadolinium compound. 13 claims, no drawings

  6. Support vector regression model for the estimation of γ-ray buildup factors for multi-layer shields

    International Nuclear Information System (INIS)

    Trontl, Kresimir; Smuc, Tomislav; Pevec, Dubravko

    2007-01-01

    The accuracy of the point-kernel method, which is a widely used practical tool for γ-ray shielding calculations, strongly depends on the quality and accuracy of buildup factors used in the calculations. Although, buildup factors for single-layer shields comprised of a single material are well known, calculation of buildup factors for stratified shields, each layer comprised of different material or a combination of materials, represent a complex physical problem. Recently, a new compact mathematical model for multi-layer shield buildup factor representation has been suggested for embedding into point-kernel codes thus replacing traditionally generated complex mathematical expressions. The new regression model is based on support vector machines learning technique, which is an extension of Statistical Learning Theory. The paper gives complete description of the novel methodology with results pertaining to realistic engineering multi-layer shielding geometries. The results based on support vector regression machine learning confirm that this approach provides a framework for general, accurate and computationally acceptable multi-layer buildup factor model

  7. Method of constructing shielding wall

    International Nuclear Information System (INIS)

    Nagao, Tetsuya.

    1990-01-01

    For instance, surfaces of lead particles each formed into a sphere of about 0.5 to 0.3 mm grain size are coated with a coating material of a synthetic resin comprising a polymeric material such as teflon. Subsequently, the floated lead particle are kneaded with concrete materials and then poured into a molding die by way of a hose. After coagulation, the molding die is removed to complete shielding walls in which lead particles are scattered substantially at an equal distance. In this way, since the lead particles are mixed into the shielding walls, shielding effects can be improved by so much as the lead particles are mixed, thereby enabling to reduce the thickness of the shielding walls. Further, since the lead particles are coated with the coating material, the lead particles are insulated from the concrete materials, thereby enabling to prevent the corrosion of the lead particles. Furthermore, since the lead particles and the concrete materials can be transported with ease, operation labors can be reduced. (T.M.)

  8. Helical tomotherapy shielding calculation for an existing LINAC treatment room: sample calculation and cautions

    International Nuclear Information System (INIS)

    Wu Chuan; Guo Fanqing; Purdy, James A

    2006-01-01

    This paper reports a step-by-step shielding calculation recipe for a helical tomotherapy unit (TomoTherapy Inc., Madison, WI, USA), recently installed in an existing Varian 600C treatment room. Both primary and secondary radiations (leakage and scatter) are explicitly considered. A typical patient load is assumed. Use factor is calculated based on an analytical formula derived from the tomotherapy rotational beam delivery geometry. Leakage and scatter are included in the calculation based on corresponding measurement data as documented by TomoTherapy Inc. Our calculation result shows that, except for a small area by the therapists' console, most of the existing Varian 600C shielding is sufficient for the new tomotherapy unit. This work cautions other institutions facing the similar situation, where an HT unit is considered for an existing LINAC treatment room, more secondary shielding might be considered at some locations, due to the significantly increased secondary shielding requirement by HT. (note)

  9. The assembly of the disk shielding is finished.

    CERN Multimedia

    Vincent Hedberg

    At the end of March, the shielding project engineer, Jan Palla, could draw a sigh of relief when the fourth and final rotation of the disk shielding was carried out without incident. The two 80-ton heavy shielding assemblies were built in a horizontal position and they had to be first turned upside-down and then rotated to a vertical position during the assembly. The relatively thin disk plate with a diameter of 9 meters, made this operation quite delicate and a lot of calculation work and strengthening of the shielding was carried out before the rotations could take place. The disk shielding is being turned upside-down. The stainless steel cylinder in the centre supports the shielding as well as the small muon wheel. The two disk shielding assemblies consist of different materials such as bronze, gray steel, cast iron, stainless steel, boron doped polyethylene and lead. The project is multinational with the major pieces having been made by companies in Armenia, Serbia, Spain, Bulgaria, Italy, Slovaki...

  10. Shielding device for control rod in nuclear reactor

    International Nuclear Information System (INIS)

    Sakamaki, Kazuo; Tomatsu, Tsutomu.

    1995-01-01

    The device of the present invention shields radiation emitted from control rods to greatly reduce an operator's radiation exposure even if reactor water level is lowered and the upper portion of the control rod is exposed upon inspection of a BWR type reactor. Namely, a shield assembly has a structure comprising a set of four columnar shields in a two-row and two-column arrangement, which can be inserted into a control rod guide tube. Upon conducting inspection, the control rod is lowered into the control rod guide tube, and in this state, the columnar shields of the shield assembly are inserted to the control rod in the control rod guide tube. With such procedures, the upper portion of the control rod protruded from the control rod guide tube is covered with the shield assembly. As a result, radiation leaked from the control rod is shielded. Accordingly, irradiation in the reactor due to leaked radiation can be prevented thereby enabling to reduce an operator's radiation exposure. (I.S.)

  11. Thick Galactic Cosmic Radiation Shielding Using Atmospheric Data

    Science.gov (United States)

    Youngquist, Robert C.; Nurge, Mark A.; Starr, Stanley O.; Koontz, Steven L.

    2013-01-01

    NASA is concerned with protecting astronauts from the effects of galactic cosmic radiation and has expended substantial effort in the development of computer models to predict the shielding obtained from various materials. However, these models were only developed for shields up to about 120 g!cm2 in thickness and have predicted that shields of this thickness are insufficient to provide adequate protection for extended deep space flights. Consequently, effort is underway to extend the range of these models to thicker shields and experimental data is required to help confirm the resulting code. In this paper empirically obtained effective dose measurements from aircraft flights in the atmosphere are used to obtain the radiation shielding function of the earth's atmosphere, a very thick shield. Obtaining this result required solving an inverse problem and the method for solving it is presented. The results are shown to be in agreement with current code in the ranges where they overlap. These results are then checked and used to predict the radiation dosage under thick shields such as planetary regolith and the atmosphere of Venus.

  12. Radiation shield for PWR reactors

    International Nuclear Information System (INIS)

    Esenov, Amra; Pustovgar, Andrey

    2013-01-01

    One of the chief structures of a reactor pit is a 'dry' shield. Setting up a 'dry' shield includes the technologically complex process of thermal processing of serpentinite concrete. Modern advances in the area of materials technology permit avoiding this complex and demanding procedure, and this significantly decreases the duration, labor intensity, and cost of setting it up. (orig.)

  13. Concrete shielding exterior to iron

    International Nuclear Information System (INIS)

    Yurista, P.; Cossairt, D.

    1983-08-01

    A rule of thumb at Fermilab has been to use 3 feet of concrete exterior to iron shielding. A recent design of a shield with a severe dimensional constraint has prompted a re-evaluation of this rule of thumb and has led to the following calculations of the concrete thickness required to nullify this problem. 4 references, 4 figures

  14. Fabrication of prototype mockups of ITER shielding blanket with separable first wall

    International Nuclear Information System (INIS)

    Kosaku, Yasuo; Kuroda, Toshimasa; Enoeda, Mikio; Hatano, Toshihisa; Sato, Satoshi; Akiba, Masato

    2002-07-01

    Design of shielding blanket for ITER-FEAT applies the first wall which has the separable structure from the shield block for the purpose of radio-active waste reduction in the maintenance work and cost reduction in fabrication process. Also, it is required to have various types of slots in both of the first wall and the shield block, to reduce the eddy current for reduction of electro-magnetic force in disruption events. This report summarizes the demonstrative fabrication of the ITER shielding blanket with separable first wall performed for the shielding blanket fabrication technology development, under the task agreement of G 16 TT 108 FJ (T420-2) in ITER Engineering Design Activity Extension Period. The objectives of the demonstrative fabrication are: to demonstrate the comprehensive fabrication technique in a large scale component (e.g the joining techniques for the beryllium armor/copper alloy and copper alloy/SS, and the slotting method of the FW and shield block); to develop an improved fabrication method for the shielding blanket based on the ITER-FEAT updated design. In this work, the fabrication technique of full scale separable first wall shield blanket was confirmed by fabricating full width Be armored first wall panel, full scale of 1/2 shield block with poloidal cooling channels. As the R and D for updated cooling channel configuration, the fabrication technique of the radial channel shield block was also demonstrated. Concluding to the all R and D results, it was demonstrated successfully that the fabrication technique and optimized conditions in the results obtained under the task agreement of G 16 TT 95 FJ (T420-1) was applicable to the prototype of the separable first wall blanket module. Additionally, basic echo data of ultra-sonic test method (UT) was obtained to show the applicability of UT method for in tube access detection of defect on the Cu alloy/SS tube interface. (author)

  15. Lessons from shielding retrofits at the LAMPF/LANSCE/PSR accelerator, beam lines and target facilities

    International Nuclear Information System (INIS)

    Macek, R.J.

    1994-01-01

    The experience in the past 7 years to improve the shielding and radiation control systems at the Los Alamos Meson Physics Facility (LAMPF) and the Manuel Lujan Jr. Neutron Scattering Center (LANSCE) provides important lessons for the design of radiation control systems at future, high beam power proton accelerator facilities. Major issues confronted and insight gained in developing shielding criteria and in the use of radiation interlocks are discussed. For accelerators and beam lines requiring hands-on-maintenance, our experience suggests that shielding criteria based on accident scenarios will be more demanding than criteria based on routinely encountered beam losses. Specification and analysis of the appropriate design basis accident become all important. Mitigation by active protection systems of the consequences of potential, but severe, prompt radiation accidents has been advocated as an alternate choice to shielding retrofits for risk management at both facilities. Acceptance of active protection systems has proven elusive primarily because of the difficulty in providing convincing proof that failure of active systems (to mitigate the accident) is incredible. Results from extensive shielding assessment studies are presented including data from experimental beam spill tests, comparisons with model estimates, and evidence bearing on the limitations of line-of-sight attenuation models in complex geometries. The scope and significant characteristics of major shielding retrofit projects at the LAMPF site are illustrated by the project to improve the shielding beneath a road over a multiuse, high-intensity beam line (Line D)

  16. Developments in shielding and criticality assessment for cask design

    International Nuclear Information System (INIS)

    Watmough, M.H.; Cooper, A.J.; Croxford, R.W.

    1993-01-01

    This paper presents recent highlights from the shielding and criticality methods development programme that are of relevance to cask design. Specifically, the following points emerge: 1) the preparation of a licence application based upon UK methods and data used in a standardized fissile depletion and plutonium production model has been completed; 2) the assumptions used in the modelling of granules of broken fuel within the transport package following a postulated impact accident have been revised thereby allowing less pessimistic assessments to be performed; 3) enhancements are being made to the software used for shielding and criticality analysis enabling a more cost effective design service to be provided. These ongoing developments clearly show the activity to extend the scope of assessments while increasing the physical realism of the models. Through these developments BNFL continues to offer a comprehensive and cost effective shielding and criticality analysis service as part of its worldwide fuel transport business. (J.P.N.)

  17. Japanese contribution to the design of primary module of shielding blanket in ITER-FEAT

    International Nuclear Information System (INIS)

    Kuroda, Toshimasa; Hatano, Toshihisa; Miki, Nobuharu; Hiroki, Seiji; Enoeda, Mikio; Ohmori, Junji; Akiba, Masato

    2003-02-01

    Japanese contributions to the design activity on the shielding blanket module consisting of the separable first wall and the shield block for ITER-FEAT are compiled. Temperature and stress distributions in the first wall and the shield block are analyzed and evaluated with 2-D and 3-D models for steady state and also for transient condition according to plasma ramp-up and ramp-down. While temperatures and stresses in the first wall satisfy their allowable values, those in a front part of the shield block exceed the allowable guideline. Based on this result, design improvements are suggested. Coolant flow and pressure distributions along the complicated coolant channel in the shield block are preliminary analyzed. Though heat removal is satisfactory in all coolant channels, back flows due to choking in coolant collectors are found. Design improvements to avoid the choking are suggested. Electromagnetic forces acting on blanket modules are analyzed with detailed 3-D models of solid elements for different disruption scenarios. The maximum moment around radial axis is 1.36 MNm on module no.5 under fast upward VDE, and the maximum moment around vertical axis is 1.47 MNm on module no.1 under fast downward VDE. The supporting beam of the first wall with welded attachment to the shield block is designed. Required welding thickness and support conditions to withstand electromagnetic forces are estimated. Strength of the shield block at the region mating the flexible cartridge is also estimated. Though the shield block surface attached by the flexible cartridge shows sufficient strength, the internal thread mating the Inconel bolt would need more length. In addition, water-to-water leak detection system in case main supply/return manifolds are located within the vacuum vessel is designed. By using Kr as the tracer material, the possibility of water-to-water leak detection and the concept of the detection system are shown. The design of the shielding blanket of ITER-FEAT has

  18. Adaptive planning using megavoltage fan-beam CT for radiation therapy with testicular shielding

    International Nuclear Information System (INIS)

    Yadav, Poonam; Kozak, Kevin; Tolakanahalli, Ranjini; Ramasubramanian, V.; Paliwal, Bhudatt R.; Welsh, James S.; Rong, Yi

    2012-01-01

    This study highlights the use of adaptive planning to accommodate testicular shielding in helical tomotherapy for malignancies of the proximal thigh. Two cases of young men with large soft tissue sarcomas of the proximal thigh are presented. After multidisciplinary evaluation, preoperative radiation therapy was recommended. Both patients were referred for sperm banking and lead shields were used to minimize testicular dose during radiation therapy. To minimize imaging artifacts, kilovoltage CT (kVCT) treatment planning was conducted without shielding. Generous hypothetical contours were generated on each “planning scan” to estimate the location of the lead shield and generate a directionally blocked helical tomotherapy plan. To ensure the accuracy of each plan, megavoltage fan-beam CT (MVCT) scans were obtained at the first treatment and adaptive planning was performed to account for lead shield placement. Two important regions of interest in these cases were femurs and femoral heads. During adaptive planning for the first patient, it was observed that the virtual lead shield contour on kVCT planning images was significantly larger than the actual lead shield used for treatment. However, for the second patient, it was noted that the size of the virtual lead shield contoured on the kVCT image was significantly smaller than the actual shield size. Thus, new adaptive plans based on MVCT images were generated and used for treatment. The planning target volume was underdosed up to 2% and had higher maximum doses without adaptive planning. In conclusion, the treatment of the upper thigh, particularly in young men, presents several clinical challenges, including preservation of gonadal function. In such circumstances, adaptive planning using MVCT can ensure accurate dose delivery even in the presence of high-density testicular shields.

  19. Adaptive planning using megavoltage fan-beam CT for radiation therapy with testicular shielding

    Science.gov (United States)

    Yadav, Poonam; Kozak, Kevin; Tolakanahalli, Ranjini; Ramasubramanian, V.; Paliwal, Bhudatt R.; Welsh, James S.; Rong, Yi

    2012-01-01

    This study highlights the use of adaptive planning to accommodate testicular shielding in helical tomotherapy for malignancies of the proximal thigh. Two cases of young men with large soft tissue sarcomas of the proximal thigh are presented. After multidisciplinary evaluation, preoperative radiation therapy was recommended. Both patients were referred for sperm banking and lead shields were used to minimize testicular dose during radiation therapy. To minimize imaging artifacts, kilovoltage CT (kVCT) treatment planning was conducted without shielding. Generous hypothetical contours were generated on each “planning scan” to estimate the location of the lead shield and generate a directionally blocked helical tomotherapy plan. To ensure the accuracy of each plan, megavoltage fan-beam CT (MVCT) scans were obtained at the first treatment and adaptive planning was performed to account for lead shield placement. Two important regions of interest in these cases were femurs and femoral heads. During adaptive planning for the first patient, it was observed that the virtual lead shield contour on kVCT planning images was significantly larger than the actual lead shield used for treatment. However, for the second patient, it was noted that the size of the virtual lead shield contoured on the kVCT image was significantly smaller than the actual shield size. Thus, new adaptive plans based on MVCT images were generated and used for treatment. The planning target volume was underdosed up to 2% and had higher maximum doses without adaptive planning. In conclusion, the treatment of the upper thigh, particularly in young men, presents several clinical challenges, including preservation of gonadal function. In such circumstances, adaptive planning using MVCT can ensure accurate dose delivery even in the presence of high-density testicular shields. PMID:21925866

  20. Adaptive planning using megavoltage fan-beam CT for radiation therapy with testicular shielding

    Energy Technology Data Exchange (ETDEWEB)

    Yadav, Poonam [Department of Human Oncology, University of Wisconsin, Madison, Madison, WI (United States); Department of Medical Physics, University of Wisconsin, Madison, Madison, WI (United States); School of Advance Sciences, Vellore Institue of Technology University, Vellore, Tamil Nadu (India); Kozak, Kevin [Department of Human Oncology, University of Wisconsin, Madison, Madison, WI (United States); Tolakanahalli, Ranjini [Department of Human Oncology, University of Wisconsin, Madison, Madison, WI (United States); Department of Medical Physics, University of Wisconsin, Madison, Madison, WI (United States); Ramasubramanian, V. [School of Advance Sciences, Vellore Institue of Technology University, Vellore, Tamil Nadu (India); Paliwal, Bhudatt R. [Department of Human Oncology, University of Wisconsin, Madison, Madison, WI (United States); Department of Medical Physics, University of Wisconsin, Madison, Madison, WI (United States); University of Wisconsin, Riverview Cancer Centre, Wisconsin Rapids, WI (United States); Welsh, James S. [Department of Human Oncology, University of Wisconsin, Madison, Madison, WI (United States); Department of Medical Physics, University of Wisconsin, Madison, Madison, WI (United States); Rong, Yi, E-mail: rong@humonc.wisc.edu [Department of Human Oncology, University of Wisconsin, Madison, Madison, WI (United States); University of Wisconsin, Riverview Cancer Centre, Wisconsin Rapids, WI (United States)

    2012-07-01

    This study highlights the use of adaptive planning to accommodate testicular shielding in helical tomotherapy for malignancies of the proximal thigh. Two cases of young men with large soft tissue sarcomas of the proximal thigh are presented. After multidisciplinary evaluation, preoperative radiation therapy was recommended. Both patients were referred for sperm banking and lead shields were used to minimize testicular dose during radiation therapy. To minimize imaging artifacts, kilovoltage CT (kVCT) treatment planning was conducted without shielding. Generous hypothetical contours were generated on each 'planning scan' to estimate the location of the lead shield and generate a directionally blocked helical tomotherapy plan. To ensure the accuracy of each plan, megavoltage fan-beam CT (MVCT) scans were obtained at the first treatment and adaptive planning was performed to account for lead shield placement. Two important regions of interest in these cases were femurs and femoral heads. During adaptive planning for the first patient, it was observed that the virtual lead shield contour on kVCT planning images was significantly larger than the actual lead shield used for treatment. However, for the second patient, it was noted that the size of the virtual lead shield contoured on the kVCT image was significantly smaller than the actual shield size. Thus, new adaptive plans based on MVCT images were generated and used for treatment. The planning target volume was underdosed up to 2% and had higher maximum doses without adaptive planning. In conclusion, the treatment of the upper thigh, particularly in young men, presents several clinical challenges, including preservation of gonadal function. In such circumstances, adaptive planning using MVCT can ensure accurate dose delivery even in the presence of high-density testicular shields.

  1. Radiation shielding activities at the OECD/Nuclear Energy Agency

    International Nuclear Information System (INIS)

    Sartori, Enrico; Vaz, Pedro

    2000-01-01

    The OECD Nuclear Energy Agency (NEA) has devoted considerable effort over the years to radiation shielding issues. The issues are addressed through international working groups. These activities are carried out in close co-ordination and co-operation with the Radiation Safety Information Computational Center (RSICC). The areas of work include: basic nuclear data activities in support of radiation shielding, computer codes, shipping cask shielding applications, reactor pressure vessel dosimetry, shielding experiments database. The method of work includes organising international code comparison exercises and benchmark studies. Training courses on radiation shielding computer codes are organised regularly including hands-on experience in modelling skills. The scope of the activity covers mainly reactor shields and spent fuel transportation packages, but also fusion neutronics and in particular shielding of accelerators and irradiation facilities. (author)

  2. Spectral perturbations from silicon diode detector encapsulation and shielding in photon fields.

    Science.gov (United States)

    Eklund, Karin; Ahnesjö, Anders

    2010-11-01

    Silicon diodes are widely used as detectors for relative dose measurements in radiotherapy. The common manufacturing practice is to encapsulate the diodes in plastic for protection and to facilitate mounting in scanning devices. Diodes intended for use in photon fields commonly also have a shield of a high atomic number material (usually tungsten) integrated into the encapsulation to selectively absorb low-energy photons to which silicon diodes would otherwise over-response. However, new response models based on cavity theories and spectra calculations have been proposed for direct correction of the readout from unshielded (e.g., "electron") diodes used in photon fields. This raises the question whether it is correct to assume that the spectrum in a water phantom at the location of the detector cavity is not perturbed by the detector encapsulation materials. The aim of this work is to investigate the spectral effects of typical encapsulations, including shielding, used for clinical diodes. The effects of detector encapsulation of an unshielded and a shielded commercial diode on the spectra at the detector cavity location are studied through Monte Carlo simulations with PENELOPE-2005. Variance reduction based on correlated sampling is applied to reduce the CPU time needed for the simulations. The use of correlated sampling is found to be efficient and to not introduce any significant bias to the results. Compared to reference spectra calculated in water, the encapsulation for an unshielded diode is demonstrated to not perturb the spectrum, while a tungsten shielded diode caused not only the desired decrease in low-energy scattered photons but also a large increase of the primary electron fluence. Measurements with a shielded diode in a 6 MV photon beam proved that the shielding does not completely remove the field-size dependence of the detector response caused by the over-response from low-energy photons. Response factors of a properly corrected unshielded diode

  3. A shielding design for an accelerator-based neutron source for boron neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Hawk, A.E.; Blue, T.E. E-mail: blue.1@osu.edu; Woollard, J.E

    2004-11-01

    Research in boron neutron capture therapy (BNCT) at The Ohio State University Nuclear Engineering Department has been primarily focused on delivering a high quality neutron field for use in BNCT using an accelerator-based neutron source (ABNS). An ABNS for BNCT is composed of a proton accelerator, a high-energy beam transport system, a {sup 7}Li target, a target heat removal system (HRS), a moderator assembly, and a treatment room. The intent of this paper is to demonstrate the advantages of a shielded moderator assembly design, in terms of material requirements necessary to adequately protect radiation personnel located outside a treatment room for BNCT, over an unshielded moderator assembly design.

  4. Shielding features of quarry stone

    International Nuclear Information System (INIS)

    Hernandez V, C.; Contreras S, H.; Hernandez A, L.; Baltazar R, A.; Escareno J, E.; Mares E, C. A.; Vega C, H. R.

    2010-10-01

    Quarry stone lineal attenuation coefficient for gamma-rays has been obtained. In Zacatecas, quarry stone is widely utilized as a decorative item in buildings, however its shielding features against gamma-rays unknown. The aim of this work is to determine the shielding properties of quarry stone against γ-rays using Monte Carlo calculations where a detailed model of a good geometry experimental setup was carried out. In the calculations 10 pieces 10 X 10 cm 2 of different thickness were utilized to evaluate the photons transmission as the quarry stone thickness is increased. It was noticed that transmitted photons decay away as the shield thickness is increased, these results were fitted to an exponential function were the linear attenuation coefficient was estimated. Also, using XCOM code the linear attenuation coefficient from several keV up to 100 MeV was estimated. From the comparison between Monte Carlo results and XCOM calculations a good agreement was found. For 0.662 MeV γ-rays the attenuation coefficient of quarry stone, whose density is 2.413 g-cm -3 , is 0.1798 cm -1 , this mean a X 1/2 = 3.9 cm, X 1/4 = 7.7 cm, X 1/10 = 12.8 cm, and X 1/100 = 25.6 cm. Having the information of quarry stone performance as shielding give the chance to use this material to shield X and γ-ray facilities. (Author)

  5. Shielded cells transfer automation

    International Nuclear Information System (INIS)

    Fisher, J.J.

    1984-01-01

    Nuclear waste from shielded cells is removed, packaged, and transferred manually in many nuclear facilities. Radiation exposure is absorbed by operators during these operations and limited only through procedural controls. Technological advances in automation using robotics have allowed a production waste removal operation to be automated to reduce radiation exposure. The robotic system bags waste containers out of glove box and transfers them to a shielded container. Operators control the system outside the system work area via television cameras. 9 figures

  6. Radiation shielding method for pipes, etc

    International Nuclear Information System (INIS)

    Nagao, Tetsuya; Takahashi, Shuichi.

    1988-01-01

    Purpose: To constitute shielding walls of a dense structure around pipes and enable to reduce the wall thickness thereof upon periodical inspection, etc. for nuclear power plants. Constitution: For those portions of pipes requring shieldings, cylindrical vessels surrounding the portions are disposed and connected to a mercury supply system, a mercury discharge system and a freezing system for solidifying mercury. After charging mercury in a tank by way of a supply hose to the cylindrical vessels, the temperature of the mercury is lowered below the freezing point thereof to solidify the mercury while circulating cooling medium, to thereby form dense cylindrical radioactive-ray shielding walls. The specific gravity of mercury is greater than that of lead and, accordingly, the thickness of the shielding walls can be reduced as compared with the conventional wall thickness of the entire laminates. (Takahashi, M.)

  7. Testing of the PELSHIE shielding code using Benchmark problems and other special shielding models

    International Nuclear Information System (INIS)

    Language, A.E.; Sartori, D.E.; De Beer, G.P.

    1981-08-01

    The PELSHIE shielding code for gamma rays from point and extended sources was written in 1971 and a revised version was published in October 1979. At Pelindaba the program is used extensively due to its flexibility and ease of use for a wide range of problems. The testing of PELSHIE results with the results of a range of models and so-called Benchmark problems is desirable to determine possible weaknesses in PELSHIE. Benchmark problems, experimental data, and shielding models, some of which were resolved by the discrete-ordinates method with the ANISN and DOT 3.5 codes, were used for the efficiency test. The description of the models followed the pattern of a classical shielding problem. After the intercomparison with six different models, the usefulness of the PELSHIE code was quantitatively determined [af

  8. Shield verification and validation action matrix summary

    International Nuclear Information System (INIS)

    Boman, C.

    1992-02-01

    WSRC-RP-90-26, Certification Plan for Reactor Analysis Computer Codes, describes a series of action items to be completed for certification of reactor analysis computer codes used in Technical Specifications development and for other safety and production support calculations. Validation and verification are integral part of the certification process. This document identifies the work performed and documentation generated to satisfy these action items for the SHIELD, SHLDED, GEDIT, GENPRT, FIPROD, FPCALC, and PROCES modules of the SHIELD system, it is not certification of the complete SHIELD system. Complete certification will follow at a later date. Each action item is discussed with the justification for its completion. Specific details of the work performed are not included in this document but can be found in the references. The validation and verification effort for the SHIELD, SHLDED, GEDIT, GENPRT, FIPROD, FPCALC, and PROCES modules of the SHIELD system computer code is completed

  9. Scale-4 shipping cask shielding applications

    International Nuclear Information System (INIS)

    Broadhead, B.L.; Parks, C.V.

    1991-01-01

    This paper reports the application of the SCALE-4 shielding sequences SAS1 and SAS4 to the problem set distributed by the Organization for Economic Cooperation and Development (OECD) Working Group on Shielding Assessment of Transportation Packages. In many cases, additional comparison are made with MCNP and QADS solutions to provide a complete cross-check of methods, cross sections, geometry, etc. The results from this effort permit the evaluation of a number of approximations and effects that must be considered in a typical shielding analysis of a transportation cask

  10. Radiation shielding for TFTR DT diagnostics

    International Nuclear Information System (INIS)

    Ku, L.P.; Johnson, D.W.; Liew, S.L.

    1994-01-01

    The authors illustrate the designs of radiation shielding for the TFTR DT diagnostics using the ACX and TVTS systems as specific examples. The main emphasis here is on the radiation transport analyses carried out in support of the designs. Initial results from the DT operation indicate that the diagnostics have been functioning as anticipated and the shielding designs are satisfactory. The experience accumulated in the shielding design for the TFTR DT diagnostics should be useful and applicable to future devices, such as TPX and ITER, where many similar diagnostic systems are expected to be used

  11. Sustainability and comanagement of subsistence hunting in an indigenous reserve in Guyana.

    Science.gov (United States)

    Shaffer, Christopher A; Milstein, Marissa S; Yukuma, Charakura; Marawanaru, Elisha; Suse, Phillip

    2017-10-01

    Although hunting is a key component of subsistence strategies of many Amazonians, it is also one of the greatest threats to wildlife. Because indigenous reserves comprise over 20% of Amazonia, effective conservation often requires that conservation professionals work closely with indigenous groups to manage resource use. We used hunter-generated harvesting data in spatially explicit biodemographic models to assess the sustainability of subsistence hunting of indigenous Waiwai in Guyana. We collected data through a hunter self-monitoring program, systematic follows of hunters, and semistructured interviews. We used these data to predict future densities of 2 indicator species, spider monkeys (Ateles paniscus) and bearded sakis (Chiropotes sagulatus), under different scenarios of human population expansion and changing hunting technology. We used encounter rates from transect surveys and hunter catch-per-unit effort (CPUE) to validate model predictions. Paca (Cuniculus paca) (198 /year), Currosaw (Crax alector) (168), and spider monkey (117) were the most frequently harvested species. Predicted densities of spider monkeys were statistically indistinguishable from empirically derived transect data (Kolmogorov-Smirnov D = 0.67, p = 0.759) and CPUE (D = 0.32, p = 1.000), demonstrating the robustness of model predictions. Ateles paniscus and C. sagulatus were predicted to be extirpated from <13% of the Waiwai reserve in 20 years, even under the most intensive hunting scenarios. Our results suggest Waiwai hunting is currently sustainable, primarily due to their low population density and use of bow and arrow. Continual monitoring is necessary, however, particularly if human population increases are accompanied by a switch to shotgun-only hunting. We suggest that hunter self-monitoring and biodemographic modeling can be used effectively in a comanagement approach in which indigenous parabiologists continuously provide hunting data that is then used to update model

  12. Using natural local materials for developing special radiation shielding concretes, and deduction of its shielding characteristics

    International Nuclear Information System (INIS)

    Kharita, M. H.; Takeyeddin, M.; Al-Nassar, M.; Yousef, S.

    2006-06-01

    Concrete is considered as the most important material to be used for radiation shielding in facilities contain radioactive sources and radiation generating machines. The concrete shielding properties may vary depending on the construction of the concrete, which is highly relative to the composing aggregates i.e. aggregates consist about 70 - 80% of the total weight of normal concrete. In this project tow types of concrete used in Syria (in Damascus and Aleppo) had been studied and their shielding properties were defined for gamma ray from Cs-137 and Co-60 sources, and for neutrons from Am-Be source. About 10% reduction in HVL was found in the comparison between the tow concrete types for both neutrons and gammas. Some other types of concrete were studied using aggregates from different regions in Syria, to improve the shielding properties of concrete, and another 10% of reduction was achieved in comparison with Damascene concrete (20% in comparison with the concrete from Aleppo) for both neutrons and gamma rays. (author)

  13. [Trial manufacture of a plunger shield for a disposable plastic syringe].

    Science.gov (United States)

    Murakami, Shigeki; Emoto, Takashi; Mori, Hiroshige; Fujita, Katsuhisa; Kubo, Naoki

    2008-08-20

    A syringe-type radiopharmaceutical being supplied by a manufacturer has a syringe shield and a plunger shield, whereas an in-hospital labeling radiopharmaceutical is administered by a disposable plastic syringe without the plunger shield. In cooperation with Nihon Medi-Physics Co. Ltd., we have produced a new experimental plunger shield for the disposable plastic syringe. In order to evaluate this shielding effect, we compared the leaked radiation doses of our plunger shield with those of the syringe-type radiopharmaceutical (Medi shield type). Our plunger shield has a lead plate of 21 mm in diameter and 3 mm thick. This shield is equipped with the plunger-end of a disposal plastic syringe. We sealed 99mTc solution into a plastic syringe (Terumo Co.) of 5 ml with our plunger shield and Medi shield type of 2 ml. We measured leaked radiation doses around syringes using fluorescent glass dosimeters (Dose Ace). The number of measure points was 18. The measured doses were converted to 70 microm dose equivalent at 740 MBq of radioactivity. The results of our plunger shield and the Medi shield type were as follows: 4-13 microSv/h and 3-14 microSv/h at shielding areas, 3-545 microSv/h and 6-97 microSv/h at non-shielding areas, 42-116 microSv/h and 88-165 microSv/h in the vicinity of the syringe shield, and 1071 microSv/h and 1243 microSv/h at the front of the needle. For dose rates of shielding areas around the syringe, the shielding effects were approximately the same as those of the Medi shield type. In conclusion, our plunger shield may be useful for reducing finger exposure during the injection of an in-hospital labeled radiopharmaceutical.

  14. Erosion by pleistocene continental ice sheets in the area of the Canadian Shield

    International Nuclear Information System (INIS)

    Rutter, N.W.

    The principles, theory and knowledge on the behaviour of glaciers indicate that only confined glacier flow is a major erosional agent. Unconfined, areally flowing ice sheets such as those present over the Canadian Shield during the Pleistocene Period modified the landscape very little. The potential for deep glacial erosion in future glaciations over the Canadian Shield area is low. Nuclear waste disposal sites, based only upon potential glacial erosion, should be located a few hundred meters below the surface in competent, fractureless crystalline shield bedrock, in relatively reliefless terrain, a few hundred kilometers away from the Paleozoic boundary. (auth)

  15. Pre-installation empirical testing of room shielding for high dose rate remote afterloaders

    International Nuclear Information System (INIS)

    Klein, E.E.; Grigsby, P.W.; Williamson, J.F.; Meigooni, A.S.

    1993-01-01

    PURPOSE: Many facilities are acquiring high dose rate remote afterloading units. It is economical that these units be placed in existing shielded teletherapy rooms. Scatter-radiation barriers marginally protect uncontrolled areas from a high dose rate source especially in a room that houses a non-dynamic Cobalt-60 unit. In addition the exact thickness and material composition of the barriers are unknown and therefore, a calculation technique may give misleading results. Also, it would be impossible to evaluate an entire wall barrier by taking isolated core samples in order to assist in the calculations. A quick and inexpensive measurement of dose equivalent using a rented high activity 192Ir source evaluates the barriers and locates shielding deficiencies. METHODS AND MATERIALS: We performed transmission calculations for primary and scattered radiation based on National Council on Radiation Protection and Measurements Reports 49 and 51, respectively. We then rented a high activity 21.7 Ci (8.03 x 10(11) Bq) Ir-192 source to assess our existing teletherapy room shielding for adequacy and voids. This source was placed at the proposed location for clinical high dose rate treatment and measurements were performed. RESULTS: No deficiencies were found in controlled areas surrounding the room, but large differences were found between the calculated and measured values. Our survey located a region in the uncontrolled area above the room requiring augmented shielding which was not predicted by the calculations. A canopy shield was designed to potentially augment the shielding in the ceiling direction. CONCLUSION: Pre-installation testing by measurement is an invaluable method for locating shielding deficiencies and avoiding unnecessary enhancement of shielding particularly when there is lack of information of the inherent shielding

  16. Effects of Aperture Size on Q factor and Shielding Effectiveness of a Cubic Resonator

    Directory of Open Access Journals (Sweden)

    S. Parr

    2017-09-01

    Full Text Available The EMC properties of a cubic metallic shield are highly affected by its resonances. At the resonant frequencies, the shielding effectiveness (SE collapses, which results in high field strengths inside the cavity. This can cause failure or even breakdown of electronic devices inside the shield. The resonant behaviour is mainly determined by the quality or Q factor of the shield. In this paper, the effects of the aperture size on the Q factor and the SE of an electrically large, cubic shield are analysed. At first, a method is developed in order to determine the Q factor based on the resonance behaviour of the shield in time domain. Only the first resonance of the shield is considered therefore. The results are evaluated for different aperture diameters and compared with theory for the Q factor. The dominant coupling mechanism of electromagnetic energy into the shield is thus identified. Then the effect of aperture size on the SE is analysed. The excitation of resonances is very probable if the interfering signal is an ultrawideband (UWB pulse, which constitutes a typical intentional electromagnetic interference (IEMI scenario. Therefore, the relation between aperture size and SE is analysed using the theory of the transient SE for a broadband signal with a constant spectral density distribution. The results show, that a worst case aperture size exists, where the SE has its minimum.

  17. SHREDI, Neutron Flux and Neutron Activation in 2-D Shields by Removal Diffusion

    International Nuclear Information System (INIS)

    Daneri, A.; Toselli, G.

    1976-01-01

    1 - Nature of physical problem solved: SHREDI is a removal - diffusion neutron shielding code. The program computes neutron fluxes and activations in bidimensional sections (x,y or r,z) of the shield. It is also possible to consider shielding points with the same y or z coordinate (mono-dimensional problems). 2 - Method of solution: The integrals which define the removal fluxes are computed in some shield points by means of a particular algorithm based on the Simpson's and trapezoidal rules. For the diffusion calculation the finite difference method is used. The removal sources are interpolated in all diffusion points by Chebyshev polynomials. 3 - Restrictions on the complexity of the problem: Maxima: number of removal energy groups NGR = 40; number of diffusion energy groups NGD = 40; number of the reactor core and shield materials NCMP = 50; number of core mesh points in r (or x) direction for integral calculation = 75; number of core mesh points in z (or y) direction for integral calculation = 75; number of core mesh points in theta (or z) direction for integral calculation = 75; number of shield mesh points for the neutron flux calculation in r (or x) direction NPX = 200; number of shield mesh points for the neutron flux calculation in z (or y) direction NPY = 200; n.b. (NPX * NPY) le 12000

  18. Monte Carlo based radial shield design of typical PWR reactor

    Energy Technology Data Exchange (ETDEWEB)

    Gul, Anas; Khan, Rustam; Qureshi, M. Ayub; Azeem, Muhammad Waqar; Raza, S.A. [Pakistan Institute of Engineering and Applied Sciences, Islamabad (Pakistan). Dept. of Nuclear Engineering; Stummer, Thomas [Technische Univ. Wien (Austria). Atominst.

    2017-04-15

    This paper presents the radiation shielding model of a typical PWR (CNPP-II) at Chashma, Pakistan. The model was developed using Monte Carlo N Particle code [2], equipped with ENDF/B-VI continuous energy cross section libraries. This model was applied to calculate the neutron and gamma flux and dose rates in the radial direction at core mid plane. The simulated results were compared with the reference results of Shanghai Nuclear Engineering Research and Design Institute (SNERDI).

  19. Radiation shielding for fission reactors

    Energy Technology Data Exchange (ETDEWEB)

    Oka, Yoshiaki [Tokyo Univ., Nuclear Engineering Research Laboratory, Tokyo (Japan)

    2000-03-01

    Radiation shielding aspects relating fission reactors have been reviewed. Domestic activities in the past five years have been mainly described concerning nuclear data, calculation methods, shielding and skyshine experiments, Advanced Boiling Water Reactor (ABWR), Advanced Pressurized Water Reactor (APWR), High Temperature Engineering Test Reactor (HTTR), Experimental and Prototype Fast Reactors (JOYO, MONJU), Demonstration FBR, core shroud replacement of BWR, and spent fuel transportation cask and vessel. These studies have valuable information in safety and cost reduction issues of fission reactor design for not only existing reactors but also new reactor concepts in the next century. It has been concluded that we should maintain existing shielding technologies and improve these data and methods for coming generations in the next millennium. (author)

  20. Neutron shielding behavior of thermoplastic natural rubber/boron carbide composites

    Science.gov (United States)

    Mat Zali, Nurazila; Yazid, Hafizal; Megat Ahmad, Megat Harun Al Rashid

    2018-01-01

    Many shielding materials have been designed against the harm of different types of radiation to the human body. Today, polymer-based lightweight composites have been chosen by the radiation protection industry. In the present study, thermoplastic natural rubber (TPNR) composites with different weight percent of boron carbide (B4C) fillers (0% to 30%) were fabricated as neutron shielding through melt blending method. Neutron attenuation properties of TPNR/B4C composites have been investigated. The macroscopic cross section (Σ), half value layer (HVL) and mean free path length (λ) of the composites have been calculated and the transmission curves have been plotted. The obtained results show that Σ, HVL and λ greatly depend on the B4C content. Addition of B4C fillers into TPNR matrix were found to enhance the macroscopic cross section values thus decrease the mean free path length (λ) and half value layer (HVL) of the composites. The transmission curves exhibited that the neutron transmission of the composites decreased with increasing shielding thickness. These results showed that TPNR/B4C composites have high potential for neutron shielding applications.

  1. Gonadal shield.

    Science.gov (United States)

    Purdy, J A; Stiteler, R D; Glasgow, G P; Mill, W B

    1975-10-01

    A secondary gonadal shield for use in the pelvic irradiation of males was designed and built using material and apparatus available with the Cerrobend blocking system. The gonadal dose was reduced to approximately 1.5 to 2.5% of the given dose.

  2. Preliminary study for development of low dose radiation shielding material using liquid silicon and metallic compound

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Seo Goo; Lee, Sung Soo [Dept. of Medical Science, Graduate School of Soonchunhyang University, Asan (Korea, Republic of); Han, Su Chul [Div. of Medical Radiation Equipment, Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of); Kang, Sung Jin [SoonChunHyang University Hospital, Seoul (Korea, Republic of); Lim, Sung Wook [Graduate school of SeJong University, Seoul (Korea, Republic of)

    2017-09-15

    This study measured and compared the protective clothing using Pb used for shielding in a diagnostic X-ray energy range, and the shielding rates of X-ray fusion shielding materials using Si and TiO{sub 2}. For the experiment, a pad type shielding with a thickness of 1 mm was prepared by mixing Si-TiO{sub 2}, and the X-ray shielding rate was compared with 0.5 mmPb plate of The shielding rate of shielding of 0.5 mmPb plate 95.92%, 85.26 % based on the case of no shielding under each 60kVp, 100kVp tube voltage condition. When the shielding of Si-TiO{sub 2} pad was applied, the shielding rate equal to or greater than 0.5 mmPb plate was obtained at a thickness of 11 mm or more, and the shielding rate of 100% or more was confirmed at a thickness of 13 nn in 60kVp condition. When the shielding of Si-TiO{sub 2} pad was applied, the shielding rate equal to or greater than 0.5 mmPb plate was obtained at a thickness of 17 mm or more, and a shielding rate of 0.5 mmPb plate was observed at a thickness of 23 mm in 100kVp condition. Through the results of this study, We could confirm the possibility of manufacturing radiation protective materials that does not contain lead hazard using various metallic compound and liquid Si. This study shows that possibility of liquid Si and other metallic compound can harmonize easily. Beside, It is flexible and strong to physical stress than Pb obtained radiation protective clothes. But additional studies are needed to increase the shielding rate and reduce the weight.

  3. Nuclear shielding of openings in ITER Tokamak building

    Energy Technology Data Exchange (ETDEWEB)

    Dammann, A., E-mail: alexis.dammann@iter.org [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Arumugam, A.P.; Beaudoin, V.; Beltran, D.; Benchikhoune, M.; Berruyer, F.; Cortes, P.; Gandini, F. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Ghirelli, N. [ASSYSTEM E.O.S, ZAC Saint Martin, 23, rue Benjamin Franklin, 84120 Pertuis (France); Gray, A.; Hurzlmeier, H.; Le Page, M. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Lemée, A. [SOGETI High Tech, 180 Rue René Descartes, 13851 Aix en Provence (France); Lentini, G.; Loughlin, M.; Mita, Y.; Patisson, L.; Rigoni, G.; Rathi, D.; Song, I. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France)

    2013-10-15

    Highlights: ► Establishment of a methodology to design shielded opening in external wall of the Tokamak building. ► Analysis of the shielding requirement, case by case, depending on the localization and the context. ► Implementation of an integrated solution for shielded opening. -- Abstract: The external walls of the Tokamak building, made of thick concrete, provide the nuclear shielding for operators working in adjacent buildings and for the environment. There are a series of openings to these external walls, devoted to ducts or pipes for ventilation, waveguides and transmission lines for heating systems and diagnostics, cooling pipes, cable trays or busbars. The shielding properties of the wall shall be preserved by adequate design of the openings in order not to affect the radiological zoning in adjacent areas. For some of them, shielding properties of the wall are not affected because the size of the network is quite small or the source is far from the opening. But for most of the openings, specific features shall be considered. Even if the approach is the same and the ways to shield can be standardized, specific analysis is requested in any case because the constraints are different.

  4. Radiation shielding fiber and its manufacturing method

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Koji; Ono, Hiroshi.

    1988-08-17

    Purpose: To manufacture radiation shielding fibers of excellent shielding effects. Method: Fibers containing more than 1 mmol/g of carboxyl groups are bonded with heavy metals, or they are impregnated with an aqueous solution containing water-soluble heavy metal salts dissolved therein. Fibers as the substrate may be any of forms such as short fibers, long fibers, fiber tows, webs, threads, knitting or woven products, non-woven fabrics, etc. It is however necessary that fibers contain more than 1 mmol/g, preferably, from 2 to 7 mmol/g of carboxylic groups. Since heavy metals having radiation shielding performance are bonded to the outer layer of the fibers and the inherent performance of the fibers per se is possessed, excellent radiation shielding performance can be obtained, as well as they can be applied with spinning, knitting or weaving, stitching, etc. thus can be used for secondary fiber products such as clothings, caps, masks, curtains, carpets, cloths, etc. for use in radiation shieldings. (Kamimura, M.).

  5. Mars Exploration Rover Heat Shield Recontact Analysis

    Science.gov (United States)

    Raiszadeh, Behzad; Desai, Prasun N.; Michelltree, Robert

    2011-01-01

    The twin Mars Exploration Rover missions landed successfully on Mars surface in January of 2004. Both missions used a parachute system to slow the rover s descent rate from supersonic to subsonic speeds. Shortly after parachute deployment, the heat shield, which protected the rover during the hypersonic entry phase of the mission, was jettisoned using push-off springs. Mission designers were concerned about the heat shield recontacting the lander after separation, so a separation analysis was conducted to quantify risks. This analysis was used to choose a proper heat shield ballast mass to ensure successful separation with low probability of recontact. This paper presents the details of such an analysis, its assumptions, and the results. During both landings, the radar was able to lock on to the heat shield, measuring its distance, as it descended away from the lander. This data is presented and is used to validate the heat shield separation/recontact analysis.

  6. Repository Waste Package Transporter Shielding Weight Optimization

    International Nuclear Information System (INIS)

    C.E. Sanders; Shiaw-Der Su

    2005-01-01

    The Yucca Mountain repository requires the use of a waste package (WP) transporter to transport a WP from a process facility on the surface to the subsurface for underground emplacement. The transporter is a part of the waste emplacement transport systems, which includes a primary locomotive at the front end and a secondary locomotive at the rear end. The overall system with a WP on board weights over 350 metric tons (MT). With the shielding mass constituting approximately one-third of the total system weight, shielding optimization for minimal weight will benefit the overall transport system with reduced axle requirements and improved maneuverability. With a high contact dose rate on the WP external surface and minimal personnel shielding afforded by the WP, the transporter provides radiation shielding to workers during waste emplacement and retrieval operations. This paper presents the design approach and optimization method used in achieving a shielding configuration with minimal weight

  7. Development of neutron shielding material using metathesis-polymer matrix

    Energy Technology Data Exchange (ETDEWEB)

    Sakurai, Yoshinori E-mail: ysakurai@rri.kyoto-u.ac.jp; Sasaki, Akira; Kobayashi, Tooru

    2004-04-21

    A neutron shielding material using a metathesis-polymer matrix, which is a thermosetting resin, was developed. This shielding material has characteristics that can be controlled for different mixing ratios of neutron absorbers and for formation in the laboratory. Additionally, the elastic modulus can be changed at the hardening process, from a flexible elastoma to a mechanically tough solid. Experiments were performed at the Kyoto University Research Reactor in order to determine the important characteristics of this metathesis-polymer shielding material, such as neutron shielding performance, secondary gamma-ray generation and activation. The metathesis-polymer shielding material was shown to be practical and as effective as the other available shielding materials, which mainly consist of thermoplastic resin.

  8. Shielding evaluation of moving bed onion irradiator by radiometry

    International Nuclear Information System (INIS)

    Venkataramani, R.; Sangurdekar, P.R.; Sarangapani, R.; Raipurkar, D.R.; Mehta, S.K.; Shastri, S.P.; Patil, K.B.; Bongirwar, D.R.

    1994-01-01

    A moving bed onion irradiator made from m.s. cladded lead slab shields designed to hold 20 kCi of 60 Co source was evaluated by radiometry with an 8 Ci 60 Co source from CRC-2 radiography camera. Some shielding losses in the irradiator noted by radiometry could be visualized by a thermocole model of the complex shielding assembly. These were rectified by appropriate lead filling. Significant shielding losses noted at cladding layer positions of slabs were attributed to lack of interlocking features in the slabs. These had to be rectified by provision of 3 TVL of additional all round shielding supplemented by local shielding at some positions. (author). 1 fig., 1 tab

  9. Status report of shielding investigation in Japan

    International Nuclear Information System (INIS)

    Shindo, M.

    1964-01-01

    The Japan Atomic Energy Research Institute (JAERI) was established in 1954, and immediately proceeded with the construction of a research reactor. The first symposium in Japan on nuclear energy was held in 1957. Most of the papers presented in the field of reactor shielding were limited to shielding materials and their fabrication. In the first stage of our investigations, our efforts were devoted to practical design studies of reactor shielding. As a result of these studies, it was found that the formulae at hand for calculations were inadequate, but at that time no electronic computer was available in Japan nor were theoretical calculations very actively undertaken. Problems on nuclear ship shielding had been investigated at the Ship Research Institute, since 1956 and many fruitful results had been obtained. About that time the Japan Atomic Industry Forum started activities and took the initiative in organizing shielding research. Research workers in the shipbuilding industry in particular have been seriously studying shielding problems. Few years after the first symposium, problems concerning more fundamental studies were treated by many research workers. Shielding experiments using radioisotopes were carried out and many fruitful results were obtained. They are described in the this paper. Medium size electronic computers became available in Japan, permitting a theoretical study group to make an active contribution. They produced some codes, and their results are also described in the following sections. This constituted the second stage of our investigations. A swimming-pool reactor, JRR-4 (Japan Research Reactor-4), has been under construction at JAERI since 1962 and will become critical in autumn 1964. After characteristic tests it will be a very powerful tool for the shielding investigations. This id the beginning of the third stage of investigations

  10. ANALISIS KESELAMATAN TERMOHIDROLIK BULK SHIELDING REAKTOR KARTINI

    Directory of Open Access Journals (Sweden)

    Azizul Khakim

    2015-10-01

    Full Text Available ABSTRAK ANALISIS KESELAMATAN TERMOHIDROLIK BULK SHIELDING REAKTOR KARTINI. Bulk shielding merupakan fasilitas yang terintegrasi dengan reaktor Kartini yang berfungsi sebagai penyimpanan sementara bahan bakar bekas. Fasilitas ini merupakan fasilitas yang termasuk dalam struktur, sistem dan komponen (SSK yang penting bagi keselamatan. Salah satu fungsi keselamatan dari sistem penanganan dan penyimpanan bahan bakar adalah mencegah kecelakaan kekritisan yang tak terkendali dan membatasi naiknya temperatur bahan bakar. Analisis keselamatan paling kurang harus mencakup analisis keselamatan dari sisi neutronik dan termo hidrolik Bulk shielding. Analisis termo hidrolik ditujukan untuk memastikan perpindahan panas dan proses pendinginan bahan bakar bekas berjalan baik dan tidak terjadi akumulasi panas yang mengancam integritas bahan bakar. Code tervalidasi PARET/ANL digunakan untuk analisis pendinginan dengan mode konveksi alam. Hasil perhitungan menunjukkan bahwa mode pendinginan konvekasi alam cukup memadai dalam mendinginkan panas sisa tanpa mengakibatkan kenaikan temperatur bahan bakar yang signifikan. Kata kunci: Bulk shielding, bahan bakar bekas, konveksi alam, PARET.   ABSTRACT THERMAL HYDRAULIC SAFETY ANALYSIS OF BULK SHIELDING KARTINI REACTOR. Bulk shielding is an integrated facility to Kartini reactor which is used for temporary spent fuels storage. The facility is one of the structures, systems and components (SSCs important to safety. Among the safety functions of fuel handling and storage are to prevent any uncontrolable criticality accidents and to limit the fuel temperature increase. Safety analyses should, at least, cover neutronic and thermal hydraulic calculations of the bulk shielding. Thermal hydraulic analyses were intended to ensure that heat removal and the process of the spent fuels cooling takes place adequately and no heat accumulation that challenges the fuel integrity. Validated code, PARET/ANL was used for analysing the

  11. An attenuation Layer for Electromagnetic Shielding in X- Band Frequency

    Directory of Open Access Journals (Sweden)

    Vida Zaroushani

    2015-06-01

    Full Text Available Uncontrolled exposure to X-band frequency leads to health damage. One of the principles of radiation protection is shielding. But, conventional shielding materials have disadvantages. Therefore, studies of novel materials, as an alternative to conventional shielding materials, are required to obtain new electromagnetic shielding material. Therefore, this study investigated the electromagnetic shielding of two component epoxy thermosetting resin for the X - band frequency with workplace approach. Two components of epoxy resin mixed according to manufacturing instruction with the weight ratio that was 100:10 .Epoxy plates fabricated in three different thicknesses (2, 4 and 6mm and shielding effectiveness measured by Vector Network Analyzer. Then, shielding effectiveness measured by the scattering parameters.The results showed that 6mm thickness of epoxy had the highest and 2mm had the lowest average of shielding effectiveness in X-band frequency that is 4.48 and 1.9 dB, respectively. Also, shielding effectiveness increased by increasing the thickness. But this increasing is useful up to 4mm. Percentage shielding effectiveness of attenuation for 6, 4 and 2mm thicknesses is 64.35%, 63.31% and 35.40%. Also, attenuation values for 4mm and 6mm thicknesses at 8.53 GHz and 8.52 GHz frequency are 77.15% and 82.95%, respectively, and can be used as favourite shields for the above frequency. 4mm-Epoxy is a suitable candidate for shielding application in X-band frequency range but, in the lower section, 6mm thickness is recommended. Finely, the shielding matrix can be used for selecting the proper thickness for electromagnetic shielding in X- Band frequency.

  12. Electron, electron-bremsstrahlung and proton depth-dose data for space-shielding applications

    Science.gov (United States)

    Seltzer, S. M.

    1979-01-01

    A data set has been developed, consisting of depth-dose distributions for omni-directional electron and proton fluxes incident on aluminum shields. The principal new feature of this work is the accurate treatment, based on detailed Monte Carlo calculations, of the electron-produced bremsstrahlung component. Results covering the energy region of interest in space-shielding calculations have been obtained for the absorbed dose (a) as a function of depth in a semi-infinite medium, (b) at the edge of slab shields, and (c) at the center of a solid sphere. The dose to a thin tissue-equivalent detector was obtained as well as that in aluminum. Various results and comparisons with other work are given.

  13. Using the Monte Carlo Coupling Technique to Evaluate the Shielding Ability of a Modular Shielding House to Accommodate Spent-Fuel Transportable Storage Casks

    International Nuclear Information System (INIS)

    Ueki, Kohtaro; Kawakami, Kazuo; Shimizu, Daisuke

    2003-01-01

    The Monte Carlo coupling technique with the coordinate transformation is used to evaluate the shielding ability of a modular shielding house that accommodates four spent-fuel transportable storage casks for two units. The effective dose rate distributions can be obtained as far as 300 m from the center of the shielding house. The coupling technique is created with the Surface Source Write (SSW) card and the Surface Source Read/Coordinate Transformation (SSR/CRT) card in the MCNP 4C continuous energy Monte Carlo code as the 'SSW-SSR/CRT calculation system'. In the present Monte Carlo coupling calculation, the total effective dose rates 100, 200, and 300 m from the center of the shielding house are estimated to be 1.69, 0.285, and 0.0826 (μSv/yr per four casks), respectively. Accordingly, if the distance between the center of the shielding house and the site boundary of the storage facility is kept at >300 m, approximately 2400 casks are able to be accommodated in the modular shielding houses, under the Japanese severe criterion of 50 μSv/yr at the site boundary. The shielding house alone satisfies not only the technical conditions but also the economic requirements.It became evident that secondary gamma rays account for >60% of the effective total dose rate at all the calculated points around the shielding house, most of which are produced from the water in the steel-water-steel shielding system of the shielding house. The remainder of the dose rate comes mostly from neutrons; the fission product and 60 Co activation gamma rays account for small percentages. Accordingly, reducing the secondary gamma rays is critical to improving not only the shielding ability but also the radiation safety of the shielding house

  14. Study on box shield tunneling method in trial field operation; Box shield koho jissho seko ni kansuru kosatsu

    Energy Technology Data Exchange (ETDEWEB)

    Tada, K.; Taniguchi, T. [Toda Corp., Tokyo, (Japan); Furukawa, K.; Nakagawa, K. [Yamaguchi University, Yamaguchi (Japan). Faculty of Engineering

    1997-03-20

    This paper describes a rectangular section shield tunneling method as a part of developments of non-circular section shield tunneling methods. The non-circular shield is drawing attention because of need of excavation in small land available in urban areas and between congested existing structures, as well as reduction in the excavated soil amount. A full-scale machine was fabricated to perform a natural ground excavation experiment. The cutter units comprising two each of drum cutters and ring cutters were arranged above and below, by which two tunnels of 40 m long with a cross section of 2.85 m {times} 2.85 m were excavated. The natural ground was supported safely by holding mud water pressures at cutting points constant, thus stability of the cutting points was ensured. Back-filling has made complete filling of tail void (clearance between a segment and the ground) possible, resulting in suppression in conditional change of the surrounding ground. Attitude control has been performed properly as a result of correct selection of shield jacks and use of deflection jacks. Broken-type over-cutters were used to have constructed tunnels with curve radius of 80 and 100 m with high accuracy. Thrust and propulsion speed of the shield do not differ from those of circular shields. Possibilities of this construction method were verified. 8 refs., 26 figs., 2 tabs.

  15. A New Mechanism for Network Monitoring and Shielding in Wireless LAN

    Directory of Open Access Journals (Sweden)

    Jiujun Cheng

    2014-01-01

    Full Text Available Wireless LAN (WLAN technology is developing rapidly with the help of wireless communication technology and social demand. During the development of WLAN, the security is more and more important, and wireless monitoring and shielding are of prime importance for network security. In this paper, we have explored various security issues of IEEE 802.11 based wireless network and analyzed numerous problems in implementing the wireless monitoring and shielding system. We identify the challenges which monitoring and shielding system needs to be aware of, and then provide a feasible mechanism to avoid those challenges. We implemented an actual wireless LAN monitoring and shielding system on Maemo operating system to monitor wireless network data stream efficiently and solve the security problems of mobile users. More importantly, the system analyzes wireless network protocols efficiently and flexibly, reveals rich information of the IEEE 802.11 protocol such as traffic distribution and different IP connections, and graphically displays later. Moreover, the system running results show that the system has the capability to work stably, and accurately and analyze the wireless protocols efficiently.

  16. Radiation shielding analysis of medical cyclotron at Radiation Medicine Centre, Parel

    International Nuclear Information System (INIS)

    Gathibandhe, M.V.; Agrawal, R.A.; Utge, C.G.

    2003-01-01

    Full text: PET (Positron Emission Tomography) is a diagnostic method to obtain 3-D functional images of the distribution of radio-nuclides introduced in the human body as tracers for specific biological processes. Tracers are produced by bombardment of different target nuclides by protons and deuterons of high energy produced in the cyclotron. A Wipro-GE medical cyclotron was installed in the basement of RMC, Parel. Shielding around the cyclotron is provided in the form of borated concrete walls of required thickness to limit dose rates to design values as per AERB criteria. The roof of the cyclotron room is made of heavy concrete. Entry in to the room is through a maze. Shielding analysis for the cyclotron room has been carried out using computer code ANISN. The maze has been analyzed using code MCNP. Based on the analysis carried out additional shielding was recommended to meet the design requirements. The paper discusses the shielding analysis carried out for the cyclotron room and the maze. Dose rate estimated at various locations are highlighted

  17. The construction of radiation shielding for baby ebm

    International Nuclear Information System (INIS)

    Mohd Rizal Md Chulan; Leo Kwee Wah; Lee Chee Huei; Muhamad Zahidee Taat; Fadzlie Nordin; Abu Bakar Mhd Ghazali; Mohd Yusof Ali; Mohd Rizal Mamat Ibrahim; Syed Nasaruddin Syed Idris; Mahmud Hamid; Mohd Khairi Mohd Said

    2005-01-01

    The construction of radiation shielding for electron beam machine, Baby EBM is necessary for prevention from x-ray (Bremstrahlung) that produced when electron bombarded the target material. The strength of produced x-ray is depending on electron energy and the atomic number of target material. In the construction process of radiation shielding, a few aspects need to be considered such as shielding material and its thickness to be used, mainframe for radiation shielding and the way fabrication to be done. In this project, the thickness of radiation shielding is calculated manually following the NCRP 51 guidelines whereas for frame design, shielding walls and fabrication is considered that the accelerator devices (accelerating tube, focusing device and neck) is vertically and the whole weight of Baby EBM. From the calculations, the thickness and the material for radiation shielding is to be used are 6mm lead. This radiation shielding has been tested (using the parameters that have been considered) to know the leak of radiation (at all surfaces) and direct radiation below 5 cm from the window. The value of high voltage that applied at accelerating tube is 80 kV and the voltage, current supply at electron gun is 3.0 V, 7.1 A respectively. The result of the testing found that dose rate under the window foil is more than 2000 mSv/hr and at all shielding surfaces are less than 0.5 mSv/hr, which is background reading and this is acceptable as compared to the theoretical calculation. The measurement was done using a survey meter typed Ludlum-model 3. (Author)

  18. The Fabrication of Internal Shielding using Provil and Cerrobend

    International Nuclear Information System (INIS)

    Kim Jong Hwa; Lee, Kang Hyun; Son, Jeong Hye

    1996-01-01

    The skin cancer is a highly curable disease which frequently occurs in the head and neck region exposed to the sun. When the eyelid is treated usually eye shield made of lead is used to protect the eyeball as a internal shield. For the same reason on internal shield should be used when the nose is treated when electron to protect the nasal mucosa. Our hospital made an internal shield for the treatment of the skin cancer on the nose using provil and cerrobend. The characteristics of the internal shield were examined.

  19. Cosmic Ray Interactions in Shielding Materials

    International Nuclear Information System (INIS)

    Aguayo Navarrete, Estanislao; Kouzes, Richard T.; Ankney, Austin S.; Orrell, John L.; Berguson, Timothy J.; Troy, Meredith D.

    2011-01-01

    This document provides a detailed study of materials used to shield against the hadronic particles from cosmic ray showers at Earth's surface. This work was motivated by the need for a shield that minimizes activation of the enriched germanium during transport for the MAJORANA collaboration. The materials suitable for cosmic-ray shield design are materials such as lead and iron that will stop the primary protons, and materials like polyethylene, borated polyethylene, concrete and water that will stop the induced neutrons. The interaction of the different cosmic-ray components at ground level (protons, neutrons, muons) with their wide energy range (from kilo-electron volts to giga-electron volts) is a complex calculation. Monte Carlo calculations have proven to be a suitable tool for the simulation of nucleon transport, including hadron interactions and radioactive isotope production. The industry standard Monte Carlo simulation tool, Geant4, was used for this study. The result of this study is the assertion that activation at Earth's surface is a result of the neutronic and protonic components of the cosmic-ray shower. The best material to shield against these cosmic-ray components is iron, which has the best combination of primary shielding and minimal secondary neutron production.

  20. Evaluation of ilmenite serpentine concrete and ordinary concrete as nuclear reactor shielding

    International Nuclear Information System (INIS)

    Abulfaraj, W.H.; Kamal, S.M.

    1994-01-01

    The present study involves adapting a formal decision methodology to the selection of alternative nuclear reactor concrete shielding. Multiattribute utility theory is selected to accommodate decision maker's preferences. Multiattribute utility theory (MAU) is here employed to evaluate two appropriate nuclear reactor shielding concretes in terms of effectiveness to determine the optimal choice in order to meet the radiation protection regulations. These concretes are Ordinary concrete (O.C.) and Illmenite Serpentile concrete (I.S.C.). These are normal weight concrete and heavy weight heat resistive concrete, respectively. The effectiveness objective of the nuclear reactor shielding is defined and structured into definite attributes and subattributes to evaluate the best alternative. Factors affecting the decision are dose received by reactor's workers, the material properties as well as cost of concrete shield. A computer program is employed to assist in performing utility analysis. Based upon data, the result shows the superiority of Ordinary concrete over Illmenite Serpentine concrete. (Author)

  1. Self-Shielding Of Transmission Lines

    Energy Technology Data Exchange (ETDEWEB)

    Christodoulou, Christos [Univ. of New Mexico, Albuquerque, NM (United States)

    2017-03-01

    The use of shielding to contend with noise or harmful EMI/EMR energy is not a new concept. An inevitable trade that must be made for shielding is physical space and weight. Space was often not as much of a painful design trade in older larger systems as they are in today’s smaller systems. Today we are packing in an exponentially growing number of functionality within the same or smaller volumes. As systems become smaller and space within systems become more restricted, the implementation of shielding becomes more problematic. Often, space that was used to design a more mechanically robust component must be used for shielding. As the system gets smaller and space is at more of a premium, the trades starts to result in defects, designs with inadequate margin in other performance areas, and designs that are sensitive to manufacturing variability. With these challenges in mind, it would be ideal to maximize attenuation of harmful fields as they inevitably couple onto transmission lines without the use of traditional shielding. Dr. Tom Van Doren proposed a design concept for transmission lines to a class of engineers while visiting New Mexico. This design concept works by maximizing Electric field (E) and Magnetic Field (H) field containment between operating transmission lines to achieve what he called “Self-Shielding”. By making the geometric centroid of the outgoing current coincident with the return current, maximum field containment is achieved. The reciprocal should be true as well, resulting in greater attenuation of incident fields. Figure’s 1(a)-1(b) are examples of designs where the current centroids are coincident. Coax cables are good examples of transmission lines with co-located centroids but they demonstrate excellent field attenuation for other reasons and can’t be used to test this design concept. Figure 1(b) is a flex circuit design that demonstrate the implementation of self-shielding vs a standard conductor layout.

  2. Shielding evaluation of neutron generator hall by Monte Carlo simulations

    Energy Technology Data Exchange (ETDEWEB)

    Pujala, U.; Selvakumaran, T.S.; Baskaran, R.; Venkatraman, B. [Radiological Safety Division, Indira Gandhi Center for Atomic Research, Kalpakkam (India); Thilagam, L.; Mohapatra, D.K., E-mail: swathythila2@yahoo.com [Safety Research Institute, Atomic Energy Regulatory Board, Kalpakkam (India)

    2017-04-01

    A shielded hall was constructed for accommodating a D-D, D-T or D-Be based pulsed neutron generator (NG) with 4π yield of 10{sup 9} n/s. The neutron shield design of the facility was optimized using NCRP-51 methodology such that the total dose rates outside the hall areas are well below the regulatory limit for full occupancy criterion (1 μSv/h). However, the total dose rates at roof top, cooling room trench exit and labyrinth exit were found to be above this limit for the optimized design. Hence, additional neutron shielding arrangements were proposed for cooling room trench and labyrinth exits. The roof top was made inaccessible. The present study is an attempt to evaluate the neutron and associated capture gamma transport through the bulk shields for the complete geometry and materials of the NG-Hall using Monte Carlo (MC) codes MCNP and FLUKA. The neutron source terms of D-D, D-T and D-Be reactions are considered in the simulations. The effect of additional shielding proposed has been demonstrated through the simulations carried out with the consideration of the additional shielding for D-Be neutron source term. The results MC simulations using two different codes are found to be consistent with each other for neutron dose rate estimates. However, deviation up to 28% is noted between these two codes at few locations for capture gamma dose rate estimates. Overall, the dose rates estimated by MC simulations including additional shields shows that all the locations surrounding the hall satisfy the full occupancy criteria for all three types of sources. Additionally, the dose rates due to direct transmission of primary neutrons estimated by FLUKA are compared with the values calculated using the formula given in NCRP-51 which shows deviations up to 50% with each other. The details of MC simulations and NCRP-51 methodology for the estimation of primary neutron dose rate along with the results are presented in this paper. (author)

  3. Validation of a new 39 neutron group self-shielded library based on the nucleonics analysis of the Lotus fusion-fission hybrid test facility performed with the Monte Carlo code

    International Nuclear Information System (INIS)

    Pelloni, S.; Cheng, E.T.

    1985-02-01

    The Swiss LOTUS fusion-fission hybrid test facility was used to investigate the influence of the self-shielding of resonance cross sections on the tritium breeding and on the thorium ratios. Nucleonic analyses were performed using the discrete-ordinates transport codes ANISN and ONEDANT, the surface-flux code SURCU, and the version 3 of the MCNP code for the Li 2 CO 3 and the Li 2 O blanket designs with lead, thorium and beryllium multipliers. Except for the MCNP calculation which bases on the ENDF/B-V files, all nuclear data are generated from the ENDF/B-IV basic library. For the deterministic methods three NJOY group libraries were considered. The first, a 39 neutron group self-shielded library, was generated at EIR. The second bases on the same group structure as the first does and consists of infinitely diluted cross sections. Finally the third library was processed at LANL and consists of coupled 30+12 neutron and gamma groups; these cross sections are not self-shielded. The Monte Carlo analysis bases on a continuous and on a discrete 262 group library from the ENDF/B-V evaluation. It is shown that the results agree well within 3% between the unshielded libraries and between the different transport codes and theories. The self-shielding of resonance cross sections results in a decrease of the thorium capture rate and in an increase of the tritium breeding of about 6%. The remaining computed ratios are not affected by the self-shielding of cross sections. (Auth.)

  4. Non-contact radio frequency shielding and wave guiding by multi-folded transformation optics method.

    Science.gov (United States)

    Madni, Hamza Ahmad; Zheng, Bin; Yang, Yihao; Wang, Huaping; Zhang, Xianmin; Yin, Wenyan; Li, Erping; Chen, Hongsheng

    2016-11-14

    Compared with conventional radio frequency (RF) shielding methods in which the conductive coating material encloses the circuits design and the leakage problem occurs due to the gap in such conductive material, non-contact RF shielding at a distance is very promising but still impossible to achieve so far. In this paper, a multi-folded transformation optics method is proposed to design a non-contact device for RF shielding. This "open-shielded" device can shield any object at a distance from the electromagnetic waves at the operating frequency, while the object is still physically open to the outer space. Based on this, an open-carpet cloak is proposed and the functionality of the open-carpet cloak is demonstrated. Furthermore, we investigate a scheme of non-contact wave guiding to remotely control the propagation of surface waves over any obstacles. The flexibilities of such multi-folded transformation optics method demonstrate the powerfulness of the method in the design of novel remote devices with impressive new functionalities.

  5. Preliminary radiation shielding design for BOOMERANG

    International Nuclear Information System (INIS)

    Donahue, Richard J.

    2002-01-01

    Preliminary radiation shielding specifications are presented here for the 3 GeV BOOMERANG Australian synchrotron light source project. At this time the bulk shield walls for the storage ring and injection system (100 MeV Linac and 3 GeV Booster) are considered for siting purposes

  6. Superconducting magnetic shields for neutral beam injectors. Final report

    International Nuclear Information System (INIS)

    1985-04-01

    Large high energy deuterium neutral beams which must be made from negative ions require extensive magnetic shielding against the intense fringe fields surrounding a magnetic fusion power plant. The feasibility of shielding by multilayer sheets of copper-superconducting laminated material was investigated. It was found that, if necessary fabrication techniques are developed, intrinsically stable type II superconductors will be able to shield against the magnetic fields of the fusion reactors. Among the immediate benefits of this research is better magnetic shields for neutral beam injectors in support of DOE's fusion program. Another application may be in the space vehicles, where difficulties in transporting heavy μ-metal sections may make a comparatively light superconducting shield attractive. Also, as high-field superconducting magnets find widespread applications, the need for high-intensity magnetic shielding will increase. As a result, the commercial market for the magnetic shields should expand along with the market for superconducting magnets

  7. Radiation shielding structure for concrete structure

    International Nuclear Information System (INIS)

    Oya, Hiroshi

    1998-01-01

    Crack inducing members for inducing cracks in a predetermined manner are buried in a concrete structure. Namely, a crack-inducing member comprises integrally a shielding plate and extended plates situated at the center of a wall and inducing plates vertically disposed to the boundary portion between them with the inducing plates being disposed each in a direction perforating the wall. There are disposed integrally a pair of the inducing plate spaced at a predetermined horizontal distance on both sides of the shielding plate so as to form a substantially crank-shaped cross section and extended plates formed in the extending direction of the shielding plate, and the inducing plates are disposed each in a direction perforating the wall. Then, cracks generated when stresses are exerted can be controlled, and generation of cracks passing through the concrete structure can be prevented reliably. The reliability of a radiation shielding effect can be enhanced remarkably. (N.H.)

  8. Verification of using SABINE-3.1 code for calculations of radioactive inventory in reactor shield

    International Nuclear Information System (INIS)

    Moukhamadeev, R.; Suvorov, A.

    2000-01-01

    This report presents the results of calculations of radioactive inventory and doses of activation radiation for the International Benchmark Calculations of Radioactive Inventory for Fission Reactor Decommissioning, IAEA, and measurements of activation doses in shield of WWER-440 (Armenian NPP), using one-dimension modified code SABINE-3.1. For decommissioning of NPP it is very important to evaluate in correct manner radioactive inventory in reactor construction and shield materials. One-dimension code SABINE-3.1 (removing-diffusion method for neutron calculation) was modified to perform calculation of radioactive inventory in reactor shield materials and dose from activation photons behind them. These calculations are carried out on the base of nuclear constant system ABBN-78 and new library of activation data for a number of long-lived isotopes, prepared by authors on the base of [9], which present at shield materials as microimpurities and manage radiation situation under the decay more than 1 year. (Authors)

  9. Adaptation of radiation shielding code to space environment

    International Nuclear Information System (INIS)

    Okuno, Koichi; Hara, Akihisa

    1992-01-01

    Recently, the trend to the development of space has heightened. To the development of space, many problems are related, and as one of them, there is the protection from cosmic ray. The cosmic ray is the radiation having ultrahigh energy, and there was not the radiation shielding design code that copes with cosmic ray so far. Therefore, the high energy radiation shielding design code for accelerators was improved so as to cope with the peculiarity that cosmic ray possesses. Moreover, the calculation of the radiation dose equivalent rate in the moon base to which the countermeasures against cosmic ray were taken was simulated by using the improved code. As the important countermeasures for the safety protection from radiation, the covering with regolith is carried out, and the effect of regolith was confirmed by using the improved code. Galactic cosmic ray, solar flare particles, radiation belt, the adaptation of the radiation shielding code HERMES to space environment, the improvement of the three-dimensional hadron cascade code HETCKFA-2 and the electromagnetic cascade code EGS 4-KFA, and the cosmic ray simulation are reported. (K.I.)

  10. Interstitial rotating shield brachytherapy for prostate cancer

    International Nuclear Information System (INIS)

    Adams, Quentin E.; Xu, Jinghzu; Breitbach, Elizabeth K.; Li, Xing; Rockey, William R.; Kim, Yusung; Wu, Xiaodong; Flynn, Ryan T.; Enger, Shirin A.

    2014-01-01

    Purpose: To present a novel needle, catheter, and radiation source system for interstitial rotating shield brachytherapy (I-RSBT) of the prostate. I-RSBT is a promising technique for reducing urethra, rectum, and bladder dose relative to conventional interstitial high-dose-rate brachytherapy (HDR-BT). Methods: A wire-mounted 62 GBq 153 Gd source is proposed with an encapsulated diameter of 0.59 mm, active diameter of 0.44 mm, and active length of 10 mm. A concept model I-RSBT needle/catheter pair was constructed using concentric 50 and 75 μm thick nickel-titanium alloy (nitinol) tubes. The needle is 16-gauge (1.651 mm) in outer diameter and the catheter contains a 535 μm thick platinum shield. I-RSBT and conventional HDR-BT treatment plans for a prostate cancer patient were generated based on Monte Carlo dose calculations. In order to minimize urethral dose, urethral dose gradient volumes within 0–5 mm of the urethra surface were allowed to receive doses less than the prescribed dose of 100%. Results: The platinum shield reduced the dose rate on the shielded side of the source at 1 cm off-axis to 6.4% of the dose rate on the unshielded side. For the case considered, for the same minimum dose to the hottest 98% of the clinical target volume (D 98% ), I-RSBT reduced urethral D 0.1cc below that of conventional HDR-BT by 29%, 33%, 38%, and 44% for urethral dose gradient volumes within 0, 1, 3, and 5 mm of the urethra surface, respectively. Percentages are expressed relative to the prescription dose of 100%. For the case considered, for the same urethral dose gradient volumes, rectum D 1cc was reduced by 7%, 6%, 6%, and 6%, respectively, and bladder D 1cc was reduced by 4%, 5%, 5%, and 6%, respectively. Treatment time to deliver 20 Gy with I-RSBT was 154 min with ten 62 GBq 153 Gd sources. Conclusions: For the case considered, the proposed 153 Gd-based I-RSBT system has the potential to lower the urethral dose relative to HDR-BT by 29%–44% if the clinician allows

  11. Evaluation of syringe shield effectiveness in handling radiopharmaceuticals

    Directory of Open Access Journals (Sweden)

    Cho Yong-In

    2015-01-01

    Full Text Available The purpose of this study was to evaluate the effectiveness of the radiation shield of radionuclide syringes and the personal dose equivalent by performing a simulation of radionuclides used in nuclear medicine diagnosis. In order to evaluate the dose depending on the distance between the radiation source and the ICRU sphere against the thickness of the shielding device, the distance at which a nuclear medicine worker may inadvertently come into contact with radiation from the radiation source was set at 0 cm to 30 cm according to the thickness of the shield, thus fixing the ICRU sphere. For a dose evaluation, Hp(10, Hp(3, and Hp(0.07 measurable in specific depth of the ICRU were evaluated. It was found that a dose measured on skin surface of nuclear medicine workers was relatively higher, that the dose varied in relation to the thickness of the radiation shield, and that the shielding effect decreased for some radiation sources such as 67Ga and 111In. It proved necessary to increase thickness of shielding device to the radiation sources such as 67Ga and 111In. It is also considered that a study of proper shielding thickness will be needed in future.

  12. Cooling Performance of TBM-shield Designed for Manufacturability

    International Nuclear Information System (INIS)

    Park, Seong Dae; Lee, Dong Won; Kim, Dong Jun; Yoon, Jae Sung; Ahn, Mu Young

    2016-01-01

    Helium cooled ceramic reflector (HCCR) test blanket module (TBM) is composed of four sub-modules and a common back manifold (BM). The associated shield is a water-cooled 316L(N)-IG block with internal cooling channels. The purpose of the TBM-shield is to make the condition with the allowable neutron flux and dose rate level. The radially continuous layers of water and structure were configured. The main purpose of the shield is to reduce the neutron flux by absorbing the neutron in the structure. The water could act as the moderator and cool down the structure which is heated due to the reaction with the neutrons. The moderated neutrons are easily absorbed by the structure. It could meet the criteria for the minimum neutron flux by increasing the thickness of structure. The formation of inside cooling channel in the TBM-shield should be considered while maintaining the allowable temperature range. In this work, a manufacturing process including the formation of inside cooling channel was presented. Current design and thermal analysis results for the TBM-shield were presented. The geometry of the shield blocks was considerably changed. The coolant channel was exposed to the outer surface of the TBM-shield. The overall manufacturing process is simplified compared with the previous process of CD model

  13. Cooling Performance of TBM-shield Designed for Manufacturability

    Energy Technology Data Exchange (ETDEWEB)

    Park, Seong Dae; Lee, Dong Won; Kim, Dong Jun; Yoon, Jae Sung [KAERI, Daejeon (Korea, Republic of); Ahn, Mu Young [NFRI, Daejeon (Korea, Republic of)

    2016-05-15

    Helium cooled ceramic reflector (HCCR) test blanket module (TBM) is composed of four sub-modules and a common back manifold (BM). The associated shield is a water-cooled 316L(N)-IG block with internal cooling channels. The purpose of the TBM-shield is to make the condition with the allowable neutron flux and dose rate level. The radially continuous layers of water and structure were configured. The main purpose of the shield is to reduce the neutron flux by absorbing the neutron in the structure. The water could act as the moderator and cool down the structure which is heated due to the reaction with the neutrons. The moderated neutrons are easily absorbed by the structure. It could meet the criteria for the minimum neutron flux by increasing the thickness of structure. The formation of inside cooling channel in the TBM-shield should be considered while maintaining the allowable temperature range. In this work, a manufacturing process including the formation of inside cooling channel was presented. Current design and thermal analysis results for the TBM-shield were presented. The geometry of the shield blocks was considerably changed. The coolant channel was exposed to the outer surface of the TBM-shield. The overall manufacturing process is simplified compared with the previous process of CD model.

  14. The status of shielding research at Tajoura research center

    International Nuclear Information System (INIS)

    El-Bakkoush, F.A.

    2005-01-01

    This paper gives a description to the shielding research activities which have been carried-out at the radiation shielding group ,Tajoura Research Center. This includes the design of different types of concrete shields made from local aggregates which have suitable radiation attenuation properties. These include, Ordinary Concrete(with density p = 2.3 ton/m3) heavy weight concrete (with density p =3.6 ton/m3) and heat resistant concrete with aggregates having bound- in water. Investigation have been carried -out by measuring the neutron and gamma-rays spectra which have been transmitted through barriers having different thickness. These were performed using a collimated beam of reactor neutrons and gamma-ray transmitted from the horizontal channel no 1 of Tajoura-Research reactor with 10 MW Max ape rating power. The transmitted fast neutron and gamma spectra were measured by neutron-gamma spectrometer employing NE-213 liquid organic scintillater. Discrimination of against undesired pulses of neutrons or gamma-ray was achieved by a pulse shape discrimination method based on differences in the shape of the decay part of the emitted pulses. The obtained results are presented in the form of displayed neutron and gamma spectra measured behind different thickness of the investigated concrete shield. These spectra were used to derive the macroscopic cross section for at different energy for material under investigation

  15. Poor Utility of Gonadal Shielding for Pediatric Pelvic Radiographs.

    Science.gov (United States)

    Lee, Mark C; Lloyd, Jessica; Solomito, Matthew J

    2017-07-01

    Plain pelvic radiographs are commonly used for a variety of pediatric orthopedic disorders. Lead shielding is typically placed over the gonads to minimize radiation exposure to these sensitive tissues. However, misplaced shielding can sabotage efforts to protect patients from excessive radiation exposure either by not covering radiosensitive tissues or by obscuring anatomic areas of interest, prompting repeat radiographic examinations. The goal of this study was to determine the incidence of misplaced shielding for pelvic radiographs obtained for pediatric orthopedic evaluation. Children 8 to 16 years old who had an anteroposterior or frog lateral pelvic radiograph between 2008 and 2014 were included. A total of 3400 patients met the inclusion criteria, and 84 boys and 84 girls were randomly selected for review. For both boys and girls, the percentage of incorrectly positioned or missing shields was calculated. Chi-square testing was used to compare the frequency of missing or incorrectly placed shields between sexes and age groups. Pelvic shields were misplaced in 49% of anteroposterior and 63% of frog lateral radiographs. Shielding was misplaced more frequently for girls than for boys on frog lateral radiographs (76% vs 51%; P<.05). Pelvic bony landmarks were often obscured by pelvic shielding, with a frequency of 7% to 43%, depending on the specific landmark. The femoral head and acetabulum were obscured by shielding in up to 2% of all images. The findings suggest that accepted pelvic shielding protocols are ineffective. Consideration should be given to alternative protocols or abandonment of this practice. [Orthopedics. 2017; 40(4):e623-e627.]. Copyright 2017, SLACK Incorporated.

  16. Development of special radiation shielding concretes using natural local materials and evaluation of their shielding characteristics

    International Nuclear Information System (INIS)

    Kharita, M. H.; Takeyeddin, M.; Al-Nassri, M.; Yousef, S.

    2008-01-01

    Concrete is one of the most important materials used for radiation shielding in facilities containing radioactive sources and radiation generating machines. The concrete shielding properties may vary depending on the composite of the concrete. Aggregates is the largest constituent (about 70-80% of the total weight of normal concrete). The aim of this work is to develop special concrete with good shielding properties for gamma and neutrons, using natural local materials. For this reason two types of typical concrete widely used in Syria (in Damascus and Aleppo) and four other types of concrete, using aggregates from different regions, have been prepared. The shielding properties of these six types were studied for gamma ray (from Cs-137 and Co-60 sources)and for neutrons (from am-Be source). A reduction of about 10% in the HVL was obtained for the concrete from Damascus in comparison with that from Aleppo, for both neutrons and gammas. One of the other four types of concrete (from Rajo site, mostly Hematite), was found to further reduce the HVL by about 10% for both neutrons and gamma rays.(author)

  17. Treerunners, cryptic lizards of the Plica plica group (Squamata, Sauria, Tropiduridae) of northern South America

    Science.gov (United States)

    Murphy, John C.; Jowers, Michael J.

    2013-01-01

    Abstract The arboreal, Neotropical lizard Plica plica (Linnaeus, 1758) has been long considered a widespread species with a distribution east of the Andes. A preliminary examination of 101 specimens from about 28 locations mostly north of the Amazon suggests that Plica plica is a cryptic species complex with taxa that can be distinguished on the basis of the number of scale rows at mid-body; the arrangement, shape and ornamentation of scales on the snout; the number of lamellae on the fourth toe; the number of subocular plates; as well as other commonly used external morphological traits. The allopatric species discussed here are concordant with northern South American geography. Plica plica (Linnaeus, 1758) is associated with the Guiana Shield (Suriname, Guyana and Venezuela). A second species, P. caribeana sp. n. is associated with the Caribbean Coastal Range of Venezuela including Trinidad and Tobago. A third, distinctive species, P. rayi sp. n. is associated with the middle Orinoco at the eastern edge of the Guiana Shield. Two other species, P. kathleenae sp. n. and P. medemi sp. n., each based upon a single specimen, one from the Sierra Acarai Mountains of Guyana, and the other from southern Meta, Colombia are described. In addition to morphological analyses, we sequenced 12S and 16S rDNA gene fragments from one Plica plica from Trinidad to assess its relationship and taxonomy to other mainland Plica cf. plica. The results suggest Plica caribeana sp. n. likely diverged prior to the separation of Trinidad from northern Venezuela. Isolation in the Caribbean Coastal Range during its rapid uplift in the late Miocene, combined with a marine incursion into northern Venezuela may have contributed to their genetic divergence from other populations. PMID:24363569

  18. Efficiency of cement - based low - weight shielding materials for Cs-137 gamma rays

    International Nuclear Information System (INIS)

    Satty, H. E. M.

    2014-10-01

    Due to the development of nuclear technology and use of technologies in various field of industry, medicine and research against ionizing radiation is one of the most important topics in this field. The purpose of this work is to reduce the dose rate from radioactive sources. The exposure to gamma radiation is leading to several health effects as the result of absorption by the human body. The frequently used shielding material for gamma rays is lead. In spite of its effectiveness and high mass attenuation coefficient, lower weight gamma shielding materials are required. In this effectiveness of three materials: carbon and mixture (50% carbon + 50% cement) was studied and compared to that of lead. The results were obtained in terms of the variations of the transmitted intensity. This is done using a gamma spectroscopy system.(Author)

  19. Irrigoscopy - irrigography method, dosimetry and radiation shielding

    International Nuclear Information System (INIS)

    Zubanov, Z.; Kolarevic, G.

    1999-01-01

    Use of patient's radiation shielding during radiology diagnostic procedures in our country is insufficiently represent, so patients needlessly receive very high entrance skin doses in body areas which are not in direct x-ray beam. During irrigoscopy, patient's radiation shielding is very complex problem, because of the organs position. In the future that problem must be solved. We hope that some of our suggestions about patient's radiation shielding during irrigoscopy, can be a small step in that way. (author)

  20. Conservative method for determination of material thickness used in shielding of veterinary facilities

    International Nuclear Information System (INIS)

    Lava, Deise D.; Borges, Diogo da S.; Affonso, Renato R.W.; Moreira, Maria de L.; Guimaraes, Antonio C.F.

    2014-01-01

    For determination of an effective method for shielding of veterinary rooms, was provided shielding methods generally used in rooms which works with X-ray production and radiotherapy. Every calculation procedure is based in traditional variables used to transmission calculation. The thickness of the materials used for primary and secondary shieldings are obtained to respect the limits set by the Brazilian National Nuclear Energy Commission (CNEN). This work presents the development of a computer code in order to serve as a practical tool for determining rapid and effective materials and their thicknesses to shield veterinary facilities. The code determines transmission values of the shieldings and compares them with data from transmission 'maps' provided by NCRP-148 report. These 'maps' were added to the algorithm through interpolation techniques of curves of materials used for shielding. Each interpolation generates about 1,000,000 points that are used to generate a new curve. The new curve is subjected to regression techniques, which makes possible to obtain nine degree polynomial, and exponential equations. These equations whose variables consist of transmission of values, enable trace all the points of this curve with high precision. The data obtained from the algorithm were satisfactory with official data presented by the National Council of Radiation Protection and Measurements (NCRP) and can contribute as a practical tool for verification of shielding of veterinary facilities that require using Radiotherapy techniques and X-ray production