WorldWideScience

Sample records for gun s-band electron

  1. Development of a Polarized Electron Gun Based on an S-Band PWT Photoinjector

    CERN Document Server

    Clendenin, J E; Yu, D; Newsham, D; Luo, Y; Smirnov, A

    2003-01-01

    An RF polarized electron gun utilizing the unique features of an integrated, plane-wave-transformer (PWT) photoelectron injector [1] is being developed by DULY Research Inc. in collaboration with SLAC. Modifications to a DULY S-band device [2] include: a re-design of the photocathode/RF backplane interface to accommodate a GaAs cathode; change in the design of the vacuum ports to provide 10-11 Torr operation; the inclusion of a load-lock photocathode replacement system to allow for reactivation and cessation of the GaAs photocathode in a vacuum; and alteration of the magnet field coils to make room for the load-lock. The use of a stainless steel outer tank and cooling rods without copper plating may also provide better vacuum performance at the expense of diminished Q factor. The effectiveness of both the standard cooling rods and synthetic diamond heat sinks for disk cooling is investigated for future linear collider applications operating at a rep rate of 180 Hz and a bunch charge of 2 nC.

  2. Transverse-emittance measurements on an S-band photocathode RF electron gun

    CERN Document Server

    Schmerge, J F; Clendenin, J E; Decker, Franz Josef; Dowell, D H; Gierman, S M; Limborg, C G; Murphy, B F

    2002-01-01

    Proposed fourth-generation light sources using SASE FELs to generate short pulse, coherent, X-rays require demonstration of high brightness electron sources. The gun test facility at SLAC was built to test high brightness sources for the proposed linac coherent light source at SLAC. The transverse-emittance measurements are made at nearly 30 MeV by measuring the spot size on a YAG screen using the quadrupole scan technique. The emittance was measured to vary from 1 to 3.5 mm mrad as the charge is increased from 50 to 350 pC using a laser pulse width of 2 ps FWHM. The measurements are in good agreement with simulation results using the LANL version of PARMELA.

  3. Design of a high repetition rate S-band photocathode gun

    International Nuclear Information System (INIS)

    Han Janghui; Cox, Matthew; Huang, Houcheng; Pande, Shivaji

    2011-01-01

    Photocathode RF guns have been developed in many laboratories for generating high quality electron beams for free-electron lasers based on linear accelerators. Such guns can generate electron beams with an exceptionally high peak current as well as a small transverse emittance. Their applications have been recently expanded for ultrafast electron diffraction, coherent terahertz radiation, and X-ray or γ-ray radiation by Compton scattering. In this paper, we design an S-band normal-conducting gun with capabilities of high quality beam generation and high repetition rate operation. The RF design and thermal analysis of the gun cavity and coupler are introduced. Optimal position of the gun focusing solenoid for low emittance beam generation is found by performing particle tracking simulations. Then, the gun system is designed to be able to afford the optimal solenoid position. The cooling-water channel surrounding the gun cavity and coupler is designed and analyzed numerically. The pressure in the gun is simulated with a vacuum model containing the detailed inner structure of the gun. An injector for a free-electron laser application is designed by using this gun and the beam dynamics simulation is shown. A cold test with a prototype gun for confirmation of the RF design is reported. - Highlights: → We design an S-band gun for low emittance beam generation and high repetition rate operation. → The RF design and thermal analysis of the gun cavity and coupler are studied. → An FEL injector is designed by using this gun and the beam dynamics simulation is shown. → A cold test with a prototype gun for confirmation of the RF design is reported.

  4. Theoretical analysis and simulation of the influence of self-bunching effects and longitudinal space charge effects on the propagation of keV electron bunch produced by a novel S-band Micro-Pulse electron Gun

    Science.gov (United States)

    Zhao, Jifei; Lu, Xiangyang; Zhou, Kui; Yang, Ziqin; Yang, Deyu; Luo, Xing; Tan, Weiwei; Yang, Yujia

    2016-06-01

    As an important electron source, Micro-Pulse electron Gun (MPG) which is qualified for producing high average current, short pulse, low emittance electron bunches steadily holds promise to use as an electron source of Coherent Smith-Purcell Radiation (CSPR), Free Electron Laser (FEL). The stable output of S-band MPG has been achieved in many labs. To establish reliable foundation for the future application of it, the propagation of picosecond electron bunch produced by MPG should be studied in detail. In this article, the MPG which was working on the rising stage of total effective Secondary Electron Yield (SEY) curve was introduced. The self-bunching mechanism was discussed in depth both in the multipacting amplifying state and the steady working state. The bunch length broadening induced by the longitudinal space-charge (SC) effects was investigated by different theoretical models in different regions. The 2D PIC codes MAGIC and beam dynamic codes TraceWin simulations were also performed in the propagation. The result shows an excellent agreement between the simulation and the theoretical analysis for bunch length evolution.

  5. Theoretical analysis and simulation of the influence of self-bunching effects and longitudinal space charge effects on the propagation of keV electron bunch produced by a novel S-band Micro-Pulse electron Gun

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Jifei; Lu, Xiangyang, E-mail: xylu@pku.edu.cn; Yang, Ziqin; Yang, Deyu; Tan, Weiwei; Yang, Yujia [Institute of Heavy Ion Physics, School of Physics, Peking University, Beijing, 100871 (China); Zhou, Kui; Luo, Xing [Institute of Applied Electronics, China Academy of Engineering Physics, Mianyang 621900 (China)

    2016-06-15

    As an important electron source, Micro-Pulse electron Gun (MPG) which is qualified for producing high average current, short pulse, low emittance electron bunches steadily holds promise to use as an electron source of Coherent Smith-Purcell Radiation (CSPR), Free Electron Laser (FEL). The stable output of S-band MPG has been achieved in many labs. To establish reliable foundation for the future application of it, the propagation of picosecond electron bunch produced by MPG should be studied in detail. In this article, the MPG which was working on the rising stage of total effective Secondary Electron Yield (SEY) curve was introduced. The self-bunching mechanism was discussed in depth both in the multipacting amplifying state and the steady working state. The bunch length broadening induced by the longitudinal space-charge (SC) effects was investigated by different theoretical models in different regions. The 2D PIC codes MAGIC and beam dynamic codes TraceWin simulations were also performed in the propagation. The result shows an excellent agreement between the simulation and the theoretical analysis for bunch length evolution.

  6. Theoretical analysis and simulation of the influence of self-bunching effects and longitudinal space charge effects on the propagation of keV electron bunch produced by a novel S-band Micro-Pulse electron Gun

    Directory of Open Access Journals (Sweden)

    Jifei Zhao

    2016-06-01

    Full Text Available As an important electron source, Micro-Pulse electron Gun (MPG which is qualified for producing high average current, short pulse, low emittance electron bunches steadily holds promise to use as an electron source of Coherent Smith-Purcell Radiation (CSPR, Free Electron Laser (FEL. The stable output of S-band MPG has been achieved in many labs. To establish reliable foundation for the future application of it, the propagation of picosecond electron bunch produced by MPG should be studied in detail. In this article, the MPG which was working on the rising stage of total effective Secondary Electron Yield (SEY curve was introduced. The self-bunching mechanism was discussed in depth both in the multipacting amplifying state and the steady working state. The bunch length broadening induced by the longitudinal space-charge (SC effects was investigated by different theoretical models in different regions. The 2D PIC codes MAGIC and beam dynamic codes TraceWin simulations were also performed in the propagation. The result shows an excellent agreement between the simulation and the theoretical analysis for bunch length evolution.

  7. Electron gun

    International Nuclear Information System (INIS)

    Chen, H.-Y.; Hughes, R.H.

    1979-01-01

    The invention described relates to cathode ray tubes, and particularly to color picture tubes of the type useful in home television receivers and therefore to electron guns. The invention is especially applicable to self-converging tube-yoke combinations with shadow mask tubes of the type having plural-beam in-line guns disposed in a horizontal plane, an apertured mask with vertically oriented slit-shaped apertures, and a screen with vertically oriented phosphor stripes. The invention is not, however, limited to use in such tubes and may in fact be used, e.g., in dot-type shadow mask tubes and index-type tubes. (Auth.)

  8. ELECTRON GUN

    Science.gov (United States)

    Christofilos, N.C.; Ehlers, K.W.

    1960-04-01

    A pulsed electron gun capable of delivering pulses at voltages of the order of 1 mv and currents of the order of 100 amperes is described. The principal novelty resides in a transformer construction which is disposed in the same vacuum housing as the electron source and accelerating electrode structure of the gun to supply the accelerating potential thereto. The transformer is provided by a plurality of magnetic cores disposed in circumferentially spaced relation and having a plurality of primary windings each inductively coupled to a different one of the cores, and a helical secondary winding which is disposed coaxially of the cores and passes therethrough in circumferential succession. Additional novelty resides in the disposition of the electron source cathode filament input leads interiorly of the transformer secondary winding which is hollow, as well as in the employment of a half-wave filament supply which is synchronously operated with the transformer supply such that the transformer is pulsed during the zero current portions of the half-wave cycle.

  9. Carbon Nanotube Electron Gun

    Science.gov (United States)

    Nguyen, Cattien V. (Inventor); Ribaya, Bryan P. (Inventor)

    2013-01-01

    An electron gun, an electron source for an electron gun, an extractor for an electron gun, and a respective method for producing the electron gun, the electron source and the extractor are disclosed. Embodiments provide an electron source utilizing a carbon nanotube (CNT) bonded to a substrate for increased stability, reliability, and durability. An extractor with an aperture in a conductive material is used to extract electrons from the electron source, where the aperture may substantially align with the CNT of the electron source when the extractor and electron source are mated to form the electron gun. The electron source and extractor may have alignment features for aligning the electron source and the extractor, thereby bringing the aperture and CNT into substantial alignment when assembled. The alignment features may provide and maintain this alignment during operation to improve the field emission characteristics and overall system stability of the electron gun.

  10. ORELA electron guns

    International Nuclear Information System (INIS)

    Christian, O.W.; Lewis, T.A.

    1981-09-01

    The most recent information concerning the production and performance of ORELA electron guns is presented. Included are descriptions of procedures for gun fabrication, cathode conditioning and high voltage processing. Highlights of the performance characteristics are also included

  11. Electron gun for SSRF

    International Nuclear Information System (INIS)

    Sheng Shugang; Lin Guoqiang; Gu Qiang; Li Deming

    2003-01-01

    A 100 kV triode-electron-gun has been designed and manufactured for the Linac of Shanghai Synchrotron Radiation Facility (SSRF). In this paper the performance of the gun and some key components are described

  12. Electron guns for accelerators

    International Nuclear Information System (INIS)

    Rangarajan, L.M.; Mahadevan, S.; Ramamurthi, S.S.

    1995-01-01

    The high voltage, high current electron guns developed elsewhere for Linacs are based on cathode pulsing with direct emitting cathodes. Our grid pulsed triode gun employs indirect emitting cathode pellet under electron bombardment or a direct cathode emitter. Electron beam from the gun is injected to the accelerator guide at 40 kV and pulse duration is 2.8μsec. The gun is limited to axially symmetric geometry and electron optical design is optimized by computer programming. The gun with a water cooled Faraday cup is connected to a vacuum system comprising of a sputter ion pump and sorption pump. Working pressure is 1x10 -6 Pa. Gun is designed to be baked as an assembly at temperatures of 400 degC while vacuum processing. Materials are therefore restricted to refractory metals, SS, OFHC copper and all the electrodes are housed inside a ceramic tube. Lower Z graphite is used as a base material of Faraday cup. Grid is non-intercepting modulator anode, a new feature introduced, as compared to meshed grid system by others. CAT gun delivers 160 mA current pulses at 40 kV and its working characteristics such as perveance, emittance and beam radius compare well with SLAC and Hermosa guns. The above guns can be used for electron beam machines such as medical Linacs, industrial accelerators and EB welding equipment. (author). 2 refs., 2 figs

  13. Bunch monitor for an S-band electron linear accelerator

    International Nuclear Information System (INIS)

    Otake, Yuji; Nakahara, Kazuo

    1991-01-01

    The measurement of bunch characteristics in an S-band electron linear accelerator is required in order to evaluate the quality of accelerated electron beams. A new-type bunch monitor has been developed which combines micro-stripline technology with an air insulator and wall-current monitoring technology. The obtained time resolution of the monitor was more than 150 ps. This result shows that the monitor can handle the bunch number of an S-band linac. The structure of the monitor is suitable for being installed in the vacuum area, since it is constructed of only metal and ceramic parts. It can therefore easily be employed in an actual machine

  14. RF Electron Gun with Driven Plasma Cathode

    CERN Document Server

    Khodak, Igor

    2005-01-01

    It's known that RF guns with plasma cathodes based on solid-state dielectrics are able to generate an intense electron beam. In this paper we describe results of experimental investigation of the single cavity S-band RF gun with driven plasma cathode. The experimental sample of the cathode based on ferroelectric ceramics has been designed. Special design of the cathode permits to separate spatially processes of plasma development and electron acceleration. It has been obtained at RF gun output electron beam with particle energy ~500 keV, pulse current of 4 A and pulse duration of 80 ns. Results of experimental study of beam parameters are referred in. The gun is purposed to be applied as the intense electron beam source for electron linacs.

  15. Ion plasma electron gun

    International Nuclear Information System (INIS)

    Wakalopulos, G.

    1976-01-01

    In the disclosed electron gun positive ions generated by a hollow cathode plasma discharge in a first chamber are accelerated through control and shield grids into a second chamber containing a high voltage cold cathode. These positive ions bombard a surface of the cathode causing the cathode to emit secondary electrons which form an electron beam having a distribution adjacent to the cathode emissive surface substantially the same as the distribution of the ion beam impinging upon the cathode. After passing through the grids and the plasma discharge chamber, the electron beam exits from the electron gun via a foil window. Control of the generated electron beam is achieved by applying a relatively low control voltage between the control grid and the electron gun housing (which resides at ground potential) to control the density of the positive ions bombarding the cathode

  16. Simulations of S-band RF gun with RF beam control

    Science.gov (United States)

    Barnyakov, A. M.; Levichev, A. E.; Maltseva, M. V.; Nikiforov, D. A.

    2017-08-01

    The RF gun with RF control is discussed. It is based on the RF triode and two kinds of the cavities. The first cavity is a coaxial cavity with cathode-grid assembly where beam bunches are formed, the second one is an accelerating cavity. The features of such a gun are the following: bunched and relativistic beams in the output of the injector, absence of the back bombarding electrons, low energy spread and short length of the bunches. The scheme of the injector is shown. The electromagnetic field simulation and longitudinal beam dynamics are presented. The possible using of the injector is discussed.

  17. High-charge s-band photocathode RF-gun and linac system for radiation research

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Tetsuya; Uesaka, Mitsuru; Katsumura, Yousuke [Univ. of Tokyo, Graduate School of Engineering, Nuclear Engineering Research Laboratory, Tokai, Ibaraki (JP)] (and others)

    2002-01-01

    For sub-picosecond pump-and-prove-type radiation chemistry work, a new synchronized electron linac and laser system was installed in the Nuclear Engineering Research Laboratory (NERL) of University of Tokyo. The new laser system, with a Ti:Sapphire oscillator (795 nm) and amplifiers, generates 300 ps pulses at 10 Hz. The laser is transported through the vacuum chamber and then split into two beams. The first is compressed and converted to the third harmonics (265 nm, <250 {mu}J, 4-11 ps) so as to drive the photocathode RF-gun and generate a pump-electron beam. The second is compressed to 100 fs and used for the probe light. The high-power RF, which is provided by a new 15 MW klystron, is divided into the gun and the accelerating section. Finally, a time jitter of 330 fs (rms) was achieved between the pump-electron beam and the probe laser, which is equivalent to the design value of 320 fs. A charge of 7 nC/bunch was observed at the exit of the gun from this new laser system. Improvement of the vacuum in the gun (<10{sup -9} Torr) is the most effective way to obtain such a high-charge beam. After about three years of operation, the Cu photocathode has shown no degradation of quantum efficiency. (author)

  18. Practical XHV electron gun

    International Nuclear Information System (INIS)

    Urata, Tomohiro; Ishikawa, Tsuyoshi; Cho, Boklae; Oshima, Chuhei

    2008-01-01

    We have developed practical XHV chambers of a electron gun, of which the operating pressures are 1x10 -9 Pa in a stainless-steel one and 4x10 -9 Pa in a permalloy one. By mounting a noble single-atom electron source with high brightness and high spatial coherence on the electron gun including electron optics, we demonstrated highly collimated electron-beam emission: ∼80% of the total emission current entered the electron optics. This ratio was two or three orders of magnitude higher than those of the conventional electron sources. In XHV, in addition, we confirmed stable electron emission up to 20 nA, which results in the specimen current high enough for scanning electron microscopes. (author)

  19. Low emittance thermionic electron guns

    International Nuclear Information System (INIS)

    Herrmannsfeldt, W.B.

    1989-01-01

    The author discusses self-field effects and external field effects for electron guns. He also discusses designs of electron guns and their uses in electron cooling systems and as an injector for electrostatic free electron lasers. He closes by looking at electron guns for linear accelerators. 20 references, 3 figures

  20. PHERMEX electron gun development

    International Nuclear Information System (INIS)

    Builta, L.A.; Elliott, J.C.; Moir, D.C.; Starke, T.P.; Vecere, C.A.

    1983-01-01

    The PHERMEX facility is a 50-MHz standing-wave linear accelerator. Electrons are injected, accelerated, and transported to a tungsten target where bremsstrahlung x rays are generated for flash radiography of hydrodynamic systems. The purpose of this article is to describe the progress of PHERMEX electron gun development. The goal of this program is to generate and transport a 200-ns, 1-MV, 1-kA electron beam into the first PHERMEX accelerating cavity. The standard gun is operated at a pulse voltage of 550 kV, which is the limit determined by internal breakdown of the vacuum insulator. This insulator has been redesigned, and the gun has been pulsed at 750 kV without internal breakdown. At present, the current output is not limited by voltage but by a phenomenon called pulse shortening, which occurs at a pulse voltage of approximately 650 kV. The phenomenon has been investigated and the results are presented

  1. Unbalanced field RF electron gun

    Science.gov (United States)

    Hofler, Alicia

    2013-11-12

    A design for an RF electron gun having a gun cavity utilizing an unbalanced electric field arrangement. Essentially, the electric field in the first (partial) cell has higher field strength than the electric field in the second (full) cell of the electron gun. The accompanying method discloses the use of the unbalanced field arrangement in the operation of an RF electron gun in order to accelerate an electron beam.

  2. Electronic emission and electron guns

    International Nuclear Information System (INIS)

    Roy, Amitava

    2010-01-01

    This paper reviews the process of electron emission from metal surface. Although electrons move freely in conductors like metals, they normally do not leave the metal without some manipulation. In fact, heating and bombardment are the two primary ways in which electrons are emitted through the use of a heating element behind the cathode (termed thermionic emission) or as a result of bombardment with a beam of electrons, ions, or metastable atoms (termed secondary emission). Another important emission mechanism called Explosive Electron Emission (EEE) is also often used in various High Voltage Pulse Power Systems to generate very high current (few hundreds of kA) pulsed electron beams. The electron gun is the device in that it shoots off a continuous (or pulsed) stream of electrons. A brief idea about the evolution of the electron gun components and their basis of functioning are also discussed. (author)

  3. Self-bunching electron guns

    Science.gov (United States)

    Mako, Frederick M.; Len, L. K.

    1999-05-01

    We report on three electron gun projects that are aimed at power tube and injector applications. The purpose of the work is to develop robust electron guns which produce self-bunched, high-current-density beams. We have demonstrated, in a microwave cavity, self-bunching, cold electron emission, long life, and tolerance to contamination. The cold process is based on secondary electron emission. FMT has studied using simulation codes the resonant bunching process which gives rise to high current densities (0.01-5 kA/cm2), high charge bunches (up to 500 nC/bunch), and short pulses (1-100 ps) for frequencies from 1 to 12 GHz. The beam pulse width is nominally ˜5% of the rf period. The first project is the L-Band Micro-Pulse Gun (MPG). Measurements show ˜40 ps long micro-bunches at ˜20 A/cm2 without contamination due to air exposure. Lifetime testing has been carried out for about 18 months operating at 1.25 GHz for almost 24 hours per day at a repetition rate of 300 Hz and 5 μs-long macro-pulses. Approximately 5.8×1013 micro-bunches or 62,000 coulombs have passed through this gun and it is still working fine. The second project, the S-Band MPG, is now operational. It is functioning at a frequency of 2.85 GHz, a repetition rate of 30 Hz, with a 2 μs-long macro-pulse. It produces about 45 A in the macro-pulse. The third project is a 34.2 GHz frequency-multiplied source driven by an X-Band MPG. A point design was performed at an rf output power of 150 MW at 34.2 GHz. The resulting system efficiency is 53% and the gain is 60 dB. The system efficiency includes the input cavity efficiency, input driver efficiency (a 50 MW klystron at 11.4 GHz), output cavity efficiency, and the post-acceleration efficiency.

  4. S-band linac-based X-ray source with {pi}/2-mode electron linac

    Energy Technology Data Exchange (ETDEWEB)

    Deshpande, Abhay, E-mail: abhay@post.kek.jp [Department of Accelerator Science, School of High Energy Accelerator Science, Graduate University for Advanced Studies, Shonan International Village, Hayama, Miura, Kanagawa 240-0193 (Japan); Society for Applied Microwave Electronic Engineering and Research (SAMEER), R and D Laboratory of the Government of India, IIT Campus, Powai, Mumbai 400 076 (India); Araki, Sakae [High Energy Accelerator Research Organization, 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Dixit, Tanuja [Society for Applied Microwave Electronic Engineering and Research (SAMEER), R and D Laboratory of the Government of India, IIT Campus, Powai, Mumbai 400 076 (India); Fukuda, Masafumi [High Energy Accelerator Research Organization, 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Krishnan, R; Pethe, Sanjay [Society for Applied Microwave Electronic Engineering and Research (SAMEER), R and D Laboratory of the Government of India, IIT Campus, Powai, Mumbai 400 076 (India); Sakaue, Kazuyuki [Waseda University, Shinjuku-ku, Tokyo 169-8555 (Japan); Terunuma, Nobuhiro; Urakawa, Junji [High Energy Accelerator Research Organization, 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Washio, Masakazu [Waseda University, Shinjuku-ku, Tokyo 169-8555 (Japan)

    2011-05-01

    The activities with the compact X-ray source are attracting more attention, particularly for the applications of the source in medical fields. We propose the fabrication of a compact X-ray source using the SAMEER electron linear accelerator and the KEK laser undulator X-ray source (LUCX) technologies. The linac developed at SAMEER is a standing wave side-coupled S-band linac operating in the {pi}/2 mode. In the proposed system, a photocathode RF gun will inject bunches of electrons in the linac to accelerate and achieve a high-energy, low-emittance beam. This beam will then interact with the laser in the laser cavity to produce X-rays of a type well suited for various applications. The side-coupled structure will make the system more compact, and the {pi}/2 mode of operation will enable a high repetition rate operation, which will help to increase the X-ray yield.

  5. The ALS gun electronics system

    International Nuclear Information System (INIS)

    Lo, C.C.

    1993-01-01

    The ALS Gun Electronics system has been designed to accommodate the gun with a custom made socket and a high speed electronics circuit which is capable of producing single and multiple electron bunches with time jitters measured at better than 50 PS. The system generates the gated RF signal at ground level before sending it up to the 120 KV-biased gun deck via a fiber optic cable. The current pulse width as a function of grid bias, using an Eimac 8847A planar triode simulating an electron gun, was measured to show the relationship between the two parameters

  6. The ALS Gun Electronics system

    International Nuclear Information System (INIS)

    Lo, C.C.

    1993-05-01

    The ALS Gun Electronics system has been designed to accommodate gun with a custom made socket and high speed electronics circuit which is capable of producing single and multiple electron bunches with time jitters measured at better than 50 PS. The system generates the gated RF signal at ground level before sending it up to the 120 KV-biased gun deck via a fiber optic cable. The current pulse width as a function of grid bias, using an Eimac 8847A planar triode simulating an electron gun, was measured to show the relationship between the two parameters

  7. Plural beam electron gun assembly

    International Nuclear Information System (INIS)

    Stratton, M.G.

    1977-01-01

    The invention relates to a cathode ray tube plural-beam-in-line bi-potential electron gun assembly, having applied beam currents of differing levels, manifests structurally modified gun structures to effect focused beam landings at the screen that are evidenced as substantially equi-sized spots thereby providing improved resolution and brightness of the screen imagery. The structural changes embody modifications of the related focusing and accelerator electrodes of the respective guns to provide a partial telescoping arrangement for effecting the discrete placement, forming and shielding of the final focusing lenses. The three lenses so formed are in different planes in partial overlapping axial relationship

  8. Reducing Energy Degradation Due to Back-bombardment Effect with Modulated RF Input in S-band Thermionic RF Gun

    Science.gov (United States)

    Kii, Toshiteru; Nakai, Yoko; Fukui, Toshio; Zen, Heishun; Kusukame, Kohichi; Okawachi, Norihito; Nakano, Masatsugu; Masuda, Kai; Ohgaki, Hideaki; Yoshikawa, Kiyoshi; Yamazaki, Tetsuo

    2007-01-01

    Energy degradation due to back-bombardment effect is quite serious to produce high-brightness electron beam with long macro-pulse with thermionic rf gun. To avoid the back-bombardment problem, a laser photo cathode is used at many FEL facilities, but usually it costs high and not easy to operate. Thus we have studied long pulse operation of the rf gun with thermionic cathode, which is inexpensive and easy to operate compared to the photocathode rf gun. In this work, to reduce the energy degradation, we controlled input rf power amplitude by controlling pulse forming network of the power modulator for klystron. We have successfully increased the pulse duration up to 4 μs by increasing the rf power from 7.8 MW to 8.5 MW during the macro pulse.

  9. Developments in electron gun simulation

    Science.gov (United States)

    Herrmannsfeldt, W. B.

    1997-01-01

    This paper will discuss the developments in the electron gun simulation programs that are based on EGUN and its derivatives and supporting programs. Much of the code development has been inspired by technology changes in computer hardware; the implications on EGN2 of this evolution will be discussed. Some examples and a review of the capabilities of the EGUN family will be described.

  10. Developments in electron gun simulation

    International Nuclear Information System (INIS)

    Herrmannsfeldt, W.B.

    1994-05-01

    This paper will discuss the developments in the electron gun simulation programs that are based on EGUN and its derivatives and supporting programs. Much of the code development has been inspired by technology changes in computer hardware; the implications on EGN2 of this evolution will be discussed. Some examples and a review of the capabilities of the EGUN family will be described

  11. Self-bunching electron guns

    CERN Document Server

    Mako, F; Weilhammer, Peter

    1999-01-01

    We report on three electron gun projects that are aimed at power tube and injector applications. The purpose of the work is to develop robust electron guns which produce self-bunched, high-current-density beams. We have demonstrated cold emission, long life, and tolerance to contamination. The cold emission process is based on secondary electron emission. FMT has studied this resonant bunching process which gives rise to high current densities (0.01-5 kA/cm/sup 2/), high charge bunches (up to 100 nC/bunch), and short pulses (1-100 ps) for frequencies from 1 to 12 GHz. The beam pulse width is nominally ~5% of the RF period. The first project is the L-Band Micro-Pulse Gun (MPG). Measurements show ~40 ps long microbunches at ~20 A/cm/sup 2/ without contamination due to air exposure. Lifetime testing has been carried out for about 18 months operating at 1.25 GHz for almost 24 hours per day at a repetition rate of 300 Hz and 5 mu s-long macro- pulses. About 5.8*10/sup 13/ micro-bunches or 62,000 coulombs have pass...

  12. Electron gun for technological linear accelerator

    International Nuclear Information System (INIS)

    Khodak, I.V.; Kushnir, V.A.; Mirochenko, V.V.; Stepin, D.L.; Zavada, L.M.

    2000-01-01

    The work is purposed to the design of diode electron gun for powerful technologic electron linac and to experimental investigations of the beam parameters at the gun exit.The gun feature is the quick cathode replacement.This is very impotent for operating of the accelerator.The gun optics and beam parameters were calculated using the EGUN code.Beam parameters were investigated as at the special test stand so as component of the linac injector.The gun produces the beam current of 2 A at the anode voltage 25 kV.Measured beam parameters correspond to calculated results

  13. Rate control for electron gun evaporation

    International Nuclear Information System (INIS)

    Schellingerhout, A.J.G.; Janocko, M.A.; Klapwijk, T.M.; Mooij, J.E.

    1989-01-01

    Principles for obtaining high-quality rate control for electron gun evaporation are discussed. The design criteria for rate controllers are derived from this analysis. Results are presented which have been obtained with e-guns whose evaporation rate is controlled by a Wehnelt electrode or by sweeping of the electron beam. Further improvements of rate stability can be obtained by improved design of e-guns and power supplies

  14. rf traveling-wave electron gun for photoinjectors

    Science.gov (United States)

    Schaer, Mattia; Citterio, Alessandro; Craievich, Paolo; Reiche, Sven; Stingelin, Lukas; Zennaro, Riccardo

    2016-07-01

    The design of a photoinjector, in particular that of the electron source, is of central importance for free electron laser (FEL) machines where a high beam brightness is required. In comparison to standard designs, an rf traveling-wave photocathode gun can provide a more rigid beam with a higher brightness and a shorter pulse. This is illustrated by applying a specific optimization procedure to the SwissFEL photoinjector, for which a brightness improvement up to a factor 3 could be achieved together with a double gun output energy compared to the reference setup foreseeing a state-of-the-art S-band rf standing-wave gun. The higher brightness is mainly given by a (at least) double peak current at the exit of the gun which brings benefits for both the beam dynamics in the linac and the efficiency of the FEL process. The gun design foresees an innovative coaxial rf coupling at both ends of the structure which allows a solenoid with integrated bucking coil to be placed around the cathode in order to provide the necessary focusing right after emission.

  15. rf traveling-wave electron gun for photoinjectors

    Directory of Open Access Journals (Sweden)

    Mattia Schaer

    2016-07-01

    Full Text Available The design of a photoinjector, in particular that of the electron source, is of central importance for free electron laser (FEL machines where a high beam brightness is required. In comparison to standard designs, an rf traveling-wave photocathode gun can provide a more rigid beam with a higher brightness and a shorter pulse. This is illustrated by applying a specific optimization procedure to the SwissFEL photoinjector, for which a brightness improvement up to a factor 3 could be achieved together with a double gun output energy compared to the reference setup foreseeing a state-of-the-art S-band rf standing-wave gun. The higher brightness is mainly given by a (at least double peak current at the exit of the gun which brings benefits for both the beam dynamics in the linac and the efficiency of the FEL process. The gun design foresees an innovative coaxial rf coupling at both ends of the structure which allows a solenoid with integrated bucking coil to be placed around the cathode in order to provide the necessary focusing right after emission.

  16. Design study of an S-band RF cavity of a dual-energy electron LINAC for the CIS

    Science.gov (United States)

    Lee, Byeong-No; Park, Hyungdal; Song, Ki-baek; Li, Yonggui; Lee, Byung Cheol; Cha, Sung-su; Lee, Jong-Chul; Shin, Seung-Wook; Chai, Jong-seo

    2014-01-01

    The design of a resonance frequency (RF) cavity for the dual-energy S-band electron linear accelerator (LINAC) has been carried out for the cargo inspection system (CIS). This Standing-wave-type RF cavity is operated at a frequency under the 2856-MHz resonance frequency and generates electron beams of 9 MeV (high mode) and 6 MeV (low mode). The electrons are accelerated from the initial energy of the electron gun to the target energy (9 or 6 MeV) inside the RF cavity by using the RF power transmitted from a 5.5-MW-class klystron. Then, electron beams with a 1-kW average power (both high mode and low mode) bombard an X-ray target a 2-mm spot size. The proposed accelerating gradient was 13 MV/m, and the designed Q value was about 7100. On going research on 15-MeV non-destructive inspections for military or other applications is presented.

  17. A low-power RF system with accurate synchronization for a S-band RF-gun using a laser-triggered photocathode

    International Nuclear Information System (INIS)

    Otake, Y.; Naito, T.; Shintake, T.; Takata, K.; Takeuchi, Y.; Urakawa, J.; Yoshioka, M.; Akiyama, H.

    1992-01-01

    An S-band RF-gun using a laser-triggered photocathode and its low-power RF system have been constructed. The main elements of the low-power RF system comprise a 600-W amplifier, an amplitude modulator, a phase detector, a phase shifter and a frequency-divider module. Synchronization between the RF fields for acceleration and the mode-locked laser pulses for beam triggering are among the important points concerning the RF-gun. The frequency divider module which down-converts from 2856 MHz(RF) to 89.25 MHz(laser), and the electrical phase-shifter were specially developed for stable phase control. The phase jitter of the frequency divider should be less than 10 ps to satisfy our present requirements. The first experiments to trigger and accelerate beams with the above-mentioned system were carried out in January, 1992. (Author) 6 figs., 5 refs

  18. The polarized electron gun for the SLC

    International Nuclear Information System (INIS)

    Schultz, D.C.; Clendenin, J.; Frisch, J.; Hoyt, E.; Klaisner, L.; Woods, M.; Wright, D.; Zolotorev, M.

    1992-03-01

    A new polarized electron gun for use on the SLC at SLAC has been built and tested. It is a diode gun with a laser driven GaAs photocathode. It is designed to provide short (2ns) pulses of 10 A at 160 kV at 120 Hz. The design features of the gun and results from a testing program on a new and dedicated beam line are presented. Early results from operation on the SLC will also be shown

  19. ECR ion source with electron gun

    Science.gov (United States)

    Xie, Zu Q.; Lyneis, Claude M.

    1993-01-01

    An Advanced Electron Cyclotron Resonance ion source (10) having an electron gun (52) for introducing electrons into the plasma chamber (18) of the ion source (10). The ion source (10) has a injection enclosure (12) and a plasma chamber tank (14). The plasma chamber (18) is defined by a plurality of longitudinal magnets (16). The electron gun (52) injects electrons axially into the plasma chamber (18) such that ionization within the plasma chamber (18) occurs in the presence of the additional electrons produced by the electron gun (52). The electron gun (52) has a cathode (116) for emitting electrons therefrom which is heated by current supplied from an AC power supply (96) while bias potential is provided by a bias power supply (118). A concentric inner conductor (60) and Outer conductor (62) carry heating current to a carbon chuck (104) and carbon pusher (114) Which hold the cathode (116) in place and also heat the cathode (16). In the Advanced Electron Cyclotron Resonance ion source (10), the electron gun (52) replaces the conventional first stage used in prior art electron cyclotron resonance ion generators.

  20. Advances in DC photocathode electron guns

    International Nuclear Information System (INIS)

    Dunham M, Bruce; Heartmann, P.; Reza Kazimi; Hongxiu Liu; Poelker, B.M.; Price, J.S.; Rutt, P.M.; Schneider, W.J.; Sinclair K, Charles

    1998-01-01

    At Jefferson Lab, a DC photoemission gun using GaAs and GaAs-like cathodes provides a source of polarized electrons for the main accelerator. The gun is required to produce high average current with long operational lifetimes and high system throughout. Recent work has shown that careful control of the parameters affecting cathode lifetime lead to dramatic improvements in source operation. These conditions include vacuum and the related effect of ion back-bombardment, and precise control of all of the electrons emitted from the cathode. In this paper, the authors will review recent results and discuss implications for future photocathode guns

  1. Advances in DC photocathode electron guns

    International Nuclear Information System (INIS)

    Dunham, B. M.; Hartmann, P.; Kazimi, R.; Liu, H.; Poelker, B. M.; Price, J. S.; Rutt, P. M.; Schneider, W. J.; Sinclair, C. K.

    1999-01-01

    At Jefferson Lab, a DC photoemission gun using GaAs and GaAs-like cathodes provides a source of polarized electrons for the main accelerator. The gun is required to produce high average current with long operational lifetimes and high system throughput. Recent work has shown that careful control of the parameters affecting cathode lifetime lead to dramatic improvements in source operation. These conditions include vacuum and the related effect of ion backbombardment, and precise control of all of the electrons emitted from the cathode. In this paper, we will review recent results and discuss implications for future photocathode guns

  2. Advances in DC photocathode electron guns

    International Nuclear Information System (INIS)

    Dunham, B.M.; Hartmann, P.; Kazimi, R.; Liu, H.; Poelker, B.M.; Price, J.S.; Rutt, P.M.; Schneider, W.J.; Sinclair, C.K.

    1999-01-01

    At Jefferson Lab, a DC photoemission gun using GaAs and GaAs-like cathodes provides a source of polarized electrons for the main accelerator. The gun is required to produce high average current with long operational lifetimes and high system throughput. Recent work has shown that careful control of the parameters affecting cathode lifetime lead to dramatic improvements in source operation. These conditions include vacuum and the related effect of ion backbombardment, and precise control of all of the electrons emitted from the cathode. In this paper, we will review recent results and discuss implications for future photocathode guns. copyright 1999 American Institute of Physics

  3. New Electron Gun System for BEPCII

    CERN Document Server

    Liu, Bo; Long Chi, Yun; Zhang, Chuang

    2005-01-01

    The new electron gun system for BEPCII has been put into operation since Nov. 2004. The article describes the design, experiment and operation of this new system. The design current of the gun is 10 A for the pulse lengths of 1 ns, 2.5 ns and 1 μs with repetition rate of 50 Hz. The gun is operated with a pulsed high voltage power supply which can provide up to 200 kV high voltage. Computer simulations have been carried out in the design stage, including simulation of the gun geometry and beam transportation. Some important relation curves are obtained during the experiment. Two-bunch operation is available and some elementary tests have been performed. New scheme of the gun control system based on EPICS is also presented. The real operation shows that the design and manufacturing is basically successful.

  4. Design of the BEPCII electron gun system

    International Nuclear Information System (INIS)

    Liu Bo; Gu Mengping; Chi Yunlong

    2006-01-01

    BEPCII upgrading project needs a new high current electron gun. The design stage such as physical design, mechanical design and control system design of this new electron gun is described. The emission current is designed to be higher than 10 A for the pulse width of 1 ns with repetition rate of 50 Hz. The gun will operate with a pulsed high voltage power supply which can provide up to 200 kV high voltage. Computer simulations and optimizations have been carried out in the design stage, including the gun geometry and beam transport. EGUN and DGUN codes are used to simulate the gun geometry, and the results show that the perveance is about 0.22 μA·V -3/2 , and the emittance at gun exit is about 16 π·mm·mrad. PARMELA code shows that the electron beam can be easily transported to the end of the first accelerating tube with a capture efficiency of 67% and root mean square emittance of 25 mm·mrad. New scheme of the gun control system based on EPICS is also presented. Two-bunch operation mode and 2.5 μs long pulse operation mode are available in the control system. (authors)

  5. Mechanical design of a RF electron gun

    International Nuclear Information System (INIS)

    Woodle, M.H.; Batchelor, K.; Sheehan, J.

    1989-01-01

    Brookhaven National Laboratory is building an Accelerator Test Facility at which we plan to study laser acceleration of electrons, inverse free electron lasers and the production of X-rays by non-linear Compton scattering. The facility contains an electron gun, linac, lasers and ancillary systems which will enable the production of 6 ps duration pulses of 50-100 MeV electrons. The electron source is an one and one half cell RF Electron gun which utilizes either a thermionic or photoemissive cathode to produce 5 MeV electrons. This paper discusses how gun mechanical design considerations such as material, vacuum maintenance, surface finish, fabrication methods, cavity tuning, and cathode replacement were reconciled to arrive at the final design. 9 refs., 2 figs., 2 tabs

  6. Mechanical design of a rf electron gun

    International Nuclear Information System (INIS)

    Woodle, M.H.; Batchelor, K.; Sheehan, J.

    1988-01-01

    Brookhaven National Laboratory is building an Accelerator Test Facility at which we plan to study laser acceleration of electrons inverse free electron lasers and the production of X-rays by non- linear Compton scattering. The facility contains an electron gun, linac, lasers and ancillary systems which will enable the production of 6 ps duration pulses of 50--100 MeV electrons. The electron source is an one and one half cell RF Electron gun which utilizes either a thermionic or photoemissive cathode to produce 5 MeV electrons. This paper discusses how gun mechanical design considerations such as material, vacuum maintenance, surface finish, fabrication methods, cavity tuning, and cathode replacement were reconciled to arrive at the final design. 9 refs., 2 figs., 2 tabs

  7. Commercialization of an S-band standing-wave electron accelerator for industrial applications

    Science.gov (United States)

    Moon, Jin-Hyeok; Kwak, Gyeong-Il; Han, Jae-Ik; Lee, Gyu-Baek; Jeon, Seong-Hwan; Kim, Jae-Young; Hwang, Cheol-Bin; Lee, Gi-Yong; Kim, Young-Man; Park, Sung-Ju

    2016-09-01

    An electron accelerator system has been developed for use in industrial, as well as possible medical, applications. Based on our experiences achieved during prototype system development and various electron beam acceleration tests, we have built a stable and compact system for sales purposes. We have integrated a self-developed accelerating cavity, an E-gun pulse driver, a radio-frequency (RF) power system, a vacuum system, a cooling system, etc. into a frame with a size of 1800 × 1000 × 1500 mm3. The accelerating structure is a side-coupled standing-wave type operating in the π/2 mode (tuned to~3 GHz). The RF power is provided by using a magnetron driven by a solid-state modulator. The electron gun is a triode type with a dispenser cathode (diameter of 11 mm). The system is capable of delivering a maximum 900-W average electron beam power with tight focusing at the target. Until now, we have performed various electron beam tests and X-ray beam tests after having built the system, have completed the beam assessment for commercializations, and have been preparing full-fledged sales activity. This article reports on our system development processes and on some of our early test results for commercializations.

  8. DC photoemission electron guns as ERL sources

    International Nuclear Information System (INIS)

    Sinclair, Charles K.

    2006-01-01

    Very-high-voltage DC electron guns, delivering moderate duration bunches from photoemission cathodes, and followed by conventional drift bunching and acceleration, offer a practical solution for an ERL injector. In a variant of this scheme, a DC gun is placed in close proximity to a superconducting RF accelerator cavity, with few or no active elements between the gun and cavity. The principal technical challenge with such electron guns arises from field emission from the cathode electrode and its support structure. Field emission may result in voltage breakdown across the cathode-anode gap, or a punch-through failure of the insulator holding off the cathode potential, as well as lesser though still serious problems. Various means to mitigate these problems are described. The operational lifetime of high quantum efficiency photocathodes in these guns is determined by the vacuum conditions, through phenomena such as chemical poisoning and ion back-bombardment. Minimization of the field strength on electrode structures pushes high-voltage DC guns toward large dimensions and, correspondingly, large outgassing loads, but it is also true that these guns offer many opportunities for achieving excellent vacuum conditions. Good solutions to vacuum problems that had previously limited cathode lifetime have been demonstrated in recent years. Designs for DC guns presently in use and planned for the near future will be described. The parameters necessary for a 100 mA average current, very-high-voltage DC gun with a photocathode operational lifetime greater than 100 h appear to be within reach, but have yet to be demonstrated. A 1 A average current source with good cathode operational lifetime will require developments beyond the present state-of-the-art

  9. Electron gun for the Fel Clio

    International Nuclear Information System (INIS)

    Chaput, R.

    1990-01-01

    A triode electron gun has been developed and manufactured at LURE (Laboratoire pour l'Utilisation du Rayonnement Electromagnetique) and LAL (Laboratoire de l'Accelerateur Lineaire) for the free electron laser CLIO 1 (Collaboration pour un laser a electrons libres dans l'infrarouge a Orsay) now under construction: this gun involves a grid-cathode assembly manufactured by EIMAC, currently used in the SLAC gun family. For the FEL requirements, the gun must be able to yield a train of short pulses at accuracy frequency or a continuous pulse. Driving together the cathode and the grid the gun produces a continous beam of 12 μs or a pulsed beam of very short pulse of 1 ns at 250 MHz, 125 MHz, 62.5 MHz or 31.25 MHz. The performances of the gun has been tested on a testing bench. A peak current of 1 Amp. for 1 ns width at any frequencies was achieved at an injection voltage of 90 kV

  10. One nanosecond pulsed electron gun systems

    International Nuclear Information System (INIS)

    Koontz, R.F.

    1979-02-01

    At SLAC there has been a continuous need for the injection of very short bunches of electrons into the accelerator. Several time-of-flight experiments have used bursts of short pulses during a normal 1.6 micro-second rf acceleration period. Single bunch beam loading experiments made use of a short pulse injection system which included high power transverse beam chopping equipment. Until the equipment described in this paper came on line, the basic grid-controlled gun pulse was limited to a rise time of 7 nanoseconds and a pulse width of 10 nanoseconds. The system described here has a grid-controlled rise time of less than 500 pico-seconds, and a minimum pulse width of less than 1 nanosecond. Pulse burst repetition rate has been demonstrated above 20 MHz during a 1.6 microsecond rf accelerating period. The order-of-magnitude increase in gun grid switching speed comes from a new gun design which minimizes lead inductance and stray capacitance, and also increases gun grid transconductance. These gun improvements coupled with a newly designed fast pulser mounted directly within the gun envelope make possible subnanosecond pulsing of the gun

  11. Development of plasma cathode electron guns

    Science.gov (United States)

    Oks, Efim M.; Schanin, Peter M.

    1999-05-01

    The status of experimental research and ongoing development of plasma cathode electron guns in recent years is reviewed, including some novel upgrades and applications to various technological fields. The attractiveness of this kind of e-gun is due to its capability of creating high current, broad or focused beams, both in pulsed and steady-state modes of operation. An important characteristic of the plasma cathode electron gun is the absence of a thermionic cathode, a feature which leads to long lifetime and reliable operation even in the presence of aggressive background gas media and at fore-vacuum gas pressure ranges such as achieved by mechanical pumps. Depending on the required beam parameters, different kinds of plasma discharge systems can be used in plasma cathode electron guns, such as vacuum arcs, constricted gaseous arcs, hollow cathode glows, and two kinds of discharges in crossed E×B fields: Penning and magnetron. At the present time, plasma cathode electron guns provide beams with transverse dimension from fractional millimeter up to about one meter, beam current from microamperes to kiloamperes, beam current density up to about 100 A/cm2, pulse duration from nanoseconds to dc, and electron energy from several keV to hundreds of keV. Applications include electron beam melting and welding, surface treatment, plasma chemistry, radiation technologies, laser pumping, microwave generation, and more.

  12. Secondary emission electron gun using external primaries

    Science.gov (United States)

    Srinivasan-Rao, Triveni [Shoreham, NY; Ben-Zvi, Ilan [Setauket, NY

    2009-10-13

    An electron gun for generating an electron beam is provided, which includes a secondary emitter. The secondary emitter includes a non-contaminating negative-electron-affinity (NEA) material and emitting surface. The gun includes an accelerating region which accelerates the secondaries from the emitting surface. The secondaries are emitted in response to a primary beam generated external to the accelerating region. The accelerating region may include a superconducting radio frequency (RF) cavity, and the gun may be operated in a continuous wave (CW) mode. The secondary emitter includes hydrogenated diamond. A uniform electrically conductive layer is superposed on the emitter to replenish the extracted current, preventing charging of the emitter. An encapsulated secondary emission enhanced cathode device, useful in a superconducting RF cavity, includes a housing for maintaining vacuum, a cathode, e.g., a photocathode, and the non-contaminating NEA secondary emitter with the uniform electrically conductive layer superposed thereon.

  13. Gun power source for electron gun of 3 MeV DC accelerator

    International Nuclear Information System (INIS)

    Dewangan, S.; Sharma, D.K.; Nanu, K.

    2011-01-01

    In DC electron beam accelerator electron gun is situated at high voltage terminal which requires constant power irrespective of beam energy. Floating power source is required for gun. This paper describes the scheme of static gun power source derived from parallel coupled voltage multiplier column. (author)

  14. A compact electron gun using field emitter array

    International Nuclear Information System (INIS)

    Asakawa, M.R.; Ikeda, A.; Miyabe, N.; Yamaguchi, S.; Kusaba, M.; Tsunawaki, Y.

    2008-01-01

    A compact electron gun using field emitter array has been developed. With a simple triode configuration consisting of FEA, mid-electrode and anode electrode, the electron gun produces a parallel beam with a diameter of 0.5 mm. This electron gun is applicable for compact radiation sources such as Cherenkov free-electron lasers

  15. Design and development of a pierce electron gun

    International Nuclear Information System (INIS)

    Bhattacharjee, D.; Tiwari, R.; Nayak, B.; Tillu, A.R.; Jayaprakash, D.; Mishra, R.L.; Mittal, K.C.; Chakravarthy, D.P.; Gantayet, L.M.

    2011-01-01

    An electron gun is designed and developed using the Pierce configuration for the focusing electrode. Simulations were carried out using CST Particle Studio. The Gun is a thermionic type electron gun with indirect heating of the LaB6 cathode. The gun is capable of delivering a beam current of 500 mA at 50 kV with a beam size of less than 3.5 mm. It was tested on the gun test bench. This paper presents the gun design, particle simulations study, testing of the gun on test bench and integration with the ECIL 9 MeV linac. (author)

  16. High-quality electron pulse generation from a laser photocathode RF gun

    International Nuclear Information System (INIS)

    Yang, Jinfeng; Sakai, Fumio; Aoki, Yasushi

    1999-01-01

    A laser photocathode RF gun system was developed for ultra short X-ray pulse generation via the inverse Compton scattering. The gun is a BNL-type S-band RF gun and the performance test of the gun was performed at the Linear Accelerator Facility in the Institute of Scientific and Industries Research, Osaka University. The gun system produced 115 pC electron bunches with the energy of 1.6 MeV under the condition of RF peak power of 1.5 MW and laser pulse energy of 65 μJ. The quantum efficiency and dark current were obtained to be 10 -5 and 0.6 nA at the repetition rate of 10 Hz, respectively. The energy and charge of the electron bunch were measured as a function of laser injection phase. Furthermore, the electron bunches were accelerated up to 117 MeV by three s-band TW linacs and the energy monochromaticity (ΔE/E) of the beam was 1.2%. The transverse emittance was also experimentally investigated at the end of the linacs. (author)

  17. Preparation of targets using electron gun systems

    International Nuclear Information System (INIS)

    Maier-Komor, P.

    1975-01-01

    Most targets of isotopes with very low vapor pressure can only be fabricated by vacuum deposition using an electron gun system or a heavy ion sputtering system. Heavy ion sputtering is a very new technique with many unsolved problems. Therefore it seems to be easier to work with an electron gun. Different commercially available electron guns, which are all designed for the high evaporation rates used in industry, are examined for their qualification in processing small amounts of material as used in fabrication of isotope targets. Electron backscattering and the associated efficiency of the electron beam power is strongly dependent on the atomic number Z of the evaporant and the incident angle of the electron beam on the surface of the evaporant. This dependence leads also to the undesired effects to the target layers from electrons and ions. Some precautions are necessary against the effects of the electrons and ions, which are formed in the plasma directly over the beam impact point. Beam power and beam density have to be chosen to get a constant evaporation rate and a low enough condensation rate in order not to overheat the target substrates. To evaporate some metals it may be helpful to pulse the electron beam

  18. A device for electron gun emittance measurement

    International Nuclear Information System (INIS)

    Aune, B.; Corveller, P.; Jablonka, M.; Joly, J.M.

    1985-05-01

    In order to improve the final emittance of the beam delivered by the ALS electron linac a new gun is going to be installed. To measure its emittance and evaluate the contribution of different factors to emittance growth we have developed an emittance measurement device. We describe the experimental and mathematical procedure we have followed, and give some results of measurements

  19. Development of the Antares electron gun

    International Nuclear Information System (INIS)

    Stine, R.; Leland, W.; Mansfield, C.; Rosocha, L.; Jansen, J.; Gibson, R.; Allen, G.

    1984-01-01

    Antares is the Los Alamos National Laboratory 40-kJ, 1-ns, CO 2 laser system that is now operational. This laser system was developed for the Intertial Confinement Fusion (ICF) program and is beginning target experiments. The distributed circuit modeling, design and operation of the large electron gun developed for the final laser power amplifier are reviewed. This gun is significant because of the large electron current area, 9 m 2 ; the number of emitter blades, 48; the dual cathode current return; and the coaxial geometry and grid control. The gun components and their development are discussed. These include the emitter blades, the coaxial grid (to maintain constant electron current during the 5-μs pulse), the bonded stacked-ring insulator (to electrically insulate the grid/cathode), the Kapton/aluminum electron transmission windows (to provide an interface between gun vacuum and laser gas) and the vacuum shell (operated at a vacuum of 10 -6 torr). A unique pressure diagnostic is also discussed

  20. Performance of photocathode rf gun electron accelerators

    International Nuclear Information System (INIS)

    Ben-Zvi, I.

    1993-01-01

    In Photo-Injectors (PI) electron guns, electrons are emitted from a photocathode by a short laser pulse and then accelerated by intense rf fields in a resonant cavity. The best known advantage of this technique is the high peak current with a good emittance (high brightness). This is important for short wavelength Free-Electron Lasers and linear colliders. PIs are in operation in many electron accelerator facilities and a large number of new guns are under construction. Some applications have emerged, providing, for example, very high pulse charges. PIs have been operated over a wide range of frequencies, from 144 to 3000 MHz (a 17 GHz gun is being developed). An exciting new possibility is the development of superconducting PIs. A significant body of experimental and theoretical work exists by now, indicating the criticality of the accelerator elements that follow the gun for the preservation of the PI's performance as well as possible avenues of improvements in brightness. Considerable research is being done on the laser and photocathode material of the PI, and improvement is expected in this area

  1. Beam Dynamics Simulation of Photocathode RF Electron Gun at the PBP-CMU Linac Laboratory

    Science.gov (United States)

    Buakor, K.; Rimjaem, S.

    2017-09-01

    Photocathode radio-frequency (RF) electron guns are widely used at many particle accelerator laboratories due to high quality of produced electron beams. By using a short-pulse laser to induce the photoemission process, the electrons are emitted with low energy spread. Moreover, the photocathode RF guns are not suffered from the electron back bombardment effect, which can cause the limited electron current and accelerated energy. In this research, we aim to develop the photocathode RF gun for the linac-based THz radiation source. Its design is based on the existing gun at the PBP-CMU Linac Laboratory. The gun consists of a one and a half cell S-band standing-wave RF cavities with a maximum electric field of about 60 MV/m at the centre of the full cell. We study the beam dynamics of electrons traveling through the electromagnetic field inside the RF gun by using the particle tracking program ASTRA. The laser properties i.e. transverse size and injecting phase are optimized to obtain low transverse emittance. In addition, the solenoid magnet is applied for beam focusing and emittance compensation. The proper solenoid magnetic field is then investigated to find the optimum value for proper emittance conservation condition.

  2. S-band 300 W pulsed solid state microwave amplifier development for driving high power klystrons for electron accelerators

    International Nuclear Information System (INIS)

    Mohania, Praveen; Shrivastava, Purushottam; Hannurkar, P.R.

    2005-01-01

    S-Band Microwave electron accelerators like microtrons and linear accelerators need pulsed microwaves from few megawatts to tens of megawatts to accelerator the electrons to desired energy and intensity. Klystron tube based driver amplifiers were used to drive the high power klystrons, which need microwave power from few tens of watts to 1 kW depending on tube output power and gain. A endeavour was initiated at Centre for Advanced Technology to develop state of art solid state S-band microwave amplifiers indigenously to drive the klystron tubes. A modular design approach was used and individual modules up to 160 W power levels were developed and tested. Finally combining 160 W modules will give up to 300 W output power. Several more modules can be combined to achieve even high power levels. Present paper describes the developmental efforts of 300 W S-band solid-state amplifiers and related microwave technologies. (author)

  3. Development of the electron gun control system of SSRF

    International Nuclear Information System (INIS)

    Zhou Dayong; Lin Guoqiang; Liu Dekang; Shen Liren

    2010-01-01

    An electron gun is the key part of a linac, the beam quality of which depends on beam quality of the electron gun, hence the need of a stable control system of the electron gun to ensure its safe operation.In this paper, we report our progresses in developing the linac's electron gun control system of Shanghai Synchrotron Radiation Facility (SSRF). It uses PLC as the device controllers, with the monitoring software developed on EPICS. The whole system is connected by Ethernet. The PLC and Ethernet technology ensures good reliability and easy maintenance of the electron gun control system. (authors)

  4. Electron gun for the positron generator

    International Nuclear Information System (INIS)

    Fukuda, S.; Ogawa, Y.; Saito, Y.

    1986-01-01

    A triode electron gun has been installed on the Positron Generator at KEK, and brought into test operation. It involves a grid-cathode assembly currently used in a planner triode. The cathode has a diameter of 10 mm and is coated with Ba-Sr-Ca oxide. Because of the short grid-cathode distance (0.18 mm), the relatively low grid pulse voltages makes it possible to draw a high current. The assembly has a small vacuum flange which allows its easy replacement. Emission current from the oxide cathode is sensitive to residual gases, therefore, the vacuum system is carefully made and the pressure is kept in the range of 10 -9 Torr even when the accelerator is on. The grid pulser is a line type pulser using multi-stage avalanche transistors as a switch. The pulse width of 10 nsec has been used for the test to investigate the gun characteristics. The performance of the gun has been tested with this pulser and the emission current of 9.7 A was achieved at an injection voltage of 110 kV. The characteristics of the gun are described together with the beam trace

  5. Low Energy Electron Gun on Board a Scientific Satellite GEOTAIL

    OpenAIRE

    TSUTSUI, Minoru; ONISHI, Yoshiaki; MATSUMOTO, Hiroshi; KIMURA, Iwane; 筒井, 稔; 大西, 嘉昭; 松本, 紘; 木村, 磐根

    1988-01-01

    A low energy electron gun to be used for beam-plasma interaction experiments by a scientific satellite GEOTAIL has been designed and manufactured. Electrodes of the gun have been modified from the Pierce type gun because of the use of a directly heated cathode. Spatial density distributions of beam electrons emitted from the new gun have been measured in a large vacuum chamber, and characteristic curves of emission currents for some beam energies and cathode powers have been checked repeatedl...

  6. The electron gun for the Daresbury SRS linac

    International Nuclear Information System (INIS)

    Dykes, D.M.

    1996-01-01

    The electron gun for the Daresbury SRS linac injector has been modified to use the cathode-grid assembly from the Eimac planar triode 8755. The gun now has improved beam characteristics, is more reliable and the cathode assembly is quicker and easier to change. This paper describes the assembly of the electron gun, and then the re-conditioning of the cathode highlighting the vacuum environment. The action of the grid modulation system on the electron beam, which pre-bunches the electron beam, is described, and typical gun characteristics are shown. Proposed developments to the gun system are discussed. (author)

  7. Progress on a cryogenically cooled RF gun polarized electron source

    Energy Technology Data Exchange (ETDEWEB)

    Fliller, R.P., III; Edwards, H.; /Fermilab

    2006-08-01

    RF guns have proven useful in multiple accelerator applications. An RF gun capable of producing polarized electrons is an attractive electron source for the ILC or an electron-ion collider. Producing such a gun has proven elusive. The NEA GaAs photocathode needed for polarized electron production is damaged by the vacuum environment in an RF gun. Electron and ion back bombardment can also damage the cathode. These problems must be mitigated before producing an RF gun polarized electron source. In this paper we report continuing efforts to improve the vacuum environment in a normal conducting RF gun by cooling it with liquid nitrogen after a high temperature vacuum bake out. We also report on a design of a cathode preparation chamber to produce bulk GaAs photocathodes for testing in such a gun. Future directions are also discussed.

  8. Electron gun controlled smart structure

    Science.gov (United States)

    Martin, Jeffrey W.; Main, John Alan; Redmond, James M.; Henson, Tammy D.; Watson, Robert D.

    2001-01-01

    Disclosed is a method and system for actively controlling the shape of a sheet of electroactive material; the system comprising: one or more electrodes attached to the frontside of the electroactive sheet; a charged particle generator, disposed so as to direct a beam of charged particles (e.g. electrons) onto the electrode; a conductive substrate attached to the backside of the sheet; and a power supply electrically connected to the conductive substrate; whereby the sheet changes its shape in response to an electric field created across the sheet by an accumulation of electric charge within the electrode(s), relative to a potential applied to the conductive substrate. Use of multiple electrodes distributed across on the frontside ensures a uniform distribution of the charge with a single point of e-beam incidence, thereby greatly simplifying the beam scanning algorithm and raster control electronics, and reducing the problems associated with "blooming". By placing a distribution of electrodes over the front surface of a piezoelectric film (or other electroactive material), this arrangement enables improved control over the distribution of surface electric charges (e.g. electrons) by creating uniform (and possibly different) charge distributions within each individual electrode. Removal or deposition of net electric charge can be affected by controlling the secondary electron yield through manipulation of the backside electric potential with the power supply. The system can be used for actively controlling the shape of space-based deployable optics, such as adaptive mirrors and inflatable antennae.

  9. CID thermionic gun system

    International Nuclear Information System (INIS)

    Koontz, R.F.

    1981-10-01

    A new high-current thermionic gun has been installed on the CID injector at SLAC and brought into operation. The gun and pulser system generate three nanosecond pulses of about six amps peak which, when bunched in the subharmonic buncher system, produce in excess of 10 11 electrons in a single S-band accelerated bunch. Preliminary operation of the gun is described, and details of the avalanche cathode drive pulser are presented

  10. CID thermionic gun system

    International Nuclear Information System (INIS)

    Koontz, R.F.

    1982-01-01

    A new high-current thermionic gun has been installed on the CID injector at SLAC and brought into operation. The gun and pulser system generate three nanosecond pulses of about six amps peak which, when bunched in the subharmonic buncher system, produce in excess of 10 11 electrons in a single S-band accelerated bunch. Preliminary operation of the gun is described, and details of the avalanche cathode drive pulser are presented

  11. A high-brightness thermionic microwave electron gun

    Energy Technology Data Exchange (ETDEWEB)

    Borland, Michael [Stanford Univ., CA (United States)

    1991-02-01

    In a collaborative effort by SSRL, AET Associates, and Varian Associates, a high-brightness microwave electron gun using a thermionic cathode has been designed, built, tested, and installed for use with the SSRL 150 MeV linear accelerator. This thesis discusses the physics behind the design and operation of the gun and associated systems, presenting predictions and experimental tests of the gun`s performance. The microwave gun concept is of increasing interest due to its promise of providing higher-current, lower-emittance electron beams than possible from conventional, DC gun technology. In a DC guns, accelerating gradients are less than 8 MV/m, while those in a microwave gun can exceed 100 MV/m, providing much more rapid initial acceleration, thereby reducing the deleterious effects of space-charge. Microwave guns produce higher momentum beams than DC guns, thus lessening space-charge effects during subsequent beam transport. Typical DC guns produce kinetic energies of 80--400 KeV, compared to 2--3 MeV for the SSRL microwave gun. ``State-of-the-art`` microwave gun designs employ laser-driven photocathodes, providing excellent performance but with greater complexity and monetary costs. A thermionic microwave gun with a magnetic bunching system is comparable in cost and complexity to a conventional system, but provides performance that is orders of magnitude better. Simulations of the SSRL microwave gun predict a normalized RMS emittance at the gun exist of < 10 π • mec • μm for a beam consisting of approximately 50% of the particles emitted from the gun, and having a momentum spread ±10%. These emittances are for up to 5 x 109e- per bunch. Chromatic aberrations in the transport line between the gun and linear accelerator increase this to typically < 30 π • me • μm.

  12. Laser-pulsed relativistic electron gun

    International Nuclear Information System (INIS)

    Sherman, N.K.

    1986-01-01

    A relativistic (β ≅ 0.8) electron gun with good emittance and subnanosecond pulse duration which can be synchronized to picosecond laser pulses is being developed at NRC for use in studies of particle acceleration by lasers. Bursts of electron pulses exceeding 280 keV in energy have been extracted into air form a laser-driven vacuum photodiode. Trains of 5 ps pulses of ultraviolet UV light illuminate a magnesium cathode. Photoelectrons emitted from the cathode are accelerated in a graded electrostatic potential set up by a 360 kV Marx-generator. The UV pulses are obtained by doubling the frequency of a 606 nm dye laser modelocked at 160 MHz. Electron energies were measured by residual range in an echelon of Al foils. Total charge per burst was measured by picoammeter. Time structure of the bursts has been examined with plastic scintillator and a fast photomultiplier. Tests on a low voltage photodiode achieved a current density of 180 A/cm/sup 2/ from an Mg cathode, with quantum efficiency of 2.4 x 10/sup -6/ electron per UV photon. The brevity and intensity of the laser pulses cause the electric charge collected per pulse to increase linearly with bias voltage rather than according to the Langmuir-Child law. Gun emittance is about 150 mm-msr and beam brightness is about 1A/cm/sup 2/-sr. Estimated duration of individual electron pulses of a burst is about 400 ps with instantaneous current of about 0.1 mA. Energy spread within one pulse is expected to be about 15%. This gun has the potential to be a useful source of relativistic electrons for laser acceleration studies

  13. A high-brightness thermionic microwave electron gun

    International Nuclear Information System (INIS)

    Borland, M.

    1991-02-01

    In a collaborative effort by SSRL, AET Associates, and Varian Associates, a high-brightness microwave electron gun using a thermionic cathode has been designed, built, tested, and installed for use with the SSRL 150 MeV linear accelerator. This thesis discusses the physics behind the design and operation of the gun and associated systems, presenting predictions and experimental tests of the gun's performance. The microwave gun concept is of increasing interest due to its promise of providing higher-current, lower-emittance electron beams than possible from conventional, DC gun technology. In a DC guns, accelerating gradients are less than 8 MV/m, while those in a microwave gun can exceed 100 MV/m, providing much more rapid initial acceleration, thereby reducing the deleterious effects of space-charge. Microwave guns produce higher momentum beams than DC guns, thus lessening space-charge effects during subsequent beam transport. Typical DC guns produce kinetic energies of 80--400 KeV, compared to 2--3 MeV for the SSRL microwave gun. ''State-of-the-art'' microwave gun designs employ laser-driven photocathodes, providing excellent performance but with greater complexity and monetary costs. A thermionic microwave gun with a magnetic bunching system is comparable in cost and complexity to a conventional system, but provides performance that is orders of magnitude better. Simulations of the SSRL microwave gun predict a normalized RMS emittance at the gun exist of e c · μm for a beam consisting of approximately 50% of the particles emitted from the gun, and having a momentum spread ±10%. These emittances are for up to 5 x 10 9 e - per bunch. Chromatic aberrations in the transport line between the gun and linear accelerator increase this to typically e · μm

  14. Performance of a carbon nanotube field emission electron gun

    Science.gov (United States)

    Getty, Stephanie A.; King, Todd T.; Bis, Rachael A.; Jones, Hollis H.; Herrero, Federico; Lynch, Bernard A.; Roman, Patrick; Mahaffy, Paul

    2007-04-01

    A cold cathode field emission electron gun (e-gun) based on a patterned carbon nanotube (CNT) film has been fabricated for use in a miniaturized reflectron time-of-flight mass spectrometer (RTOF MS), with future applications in other charged particle spectrometers, and performance of the CNT e-gun has been evaluated. A thermionic electron gun has also been fabricated and evaluated in parallel and its performance is used as a benchmark in the evaluation of our CNT e-gun. Implications for future improvements and integration into the RTOF MS are discussed.

  15. High perveance electron gun for the electron cooling system

    International Nuclear Information System (INIS)

    Korotaev, Yu.; Meshkov, I.; Petrov, A.; Sidorin, A.; Smirnov, A.; Syresin, E.; Titkova, I.

    2000-01-01

    The cooling time in the electron cooling system is inversely proportional to the beam current. To obtain high current of the electron beam the control electrode of the gun is provided with a positive potential and an electrostatic trap for secondary electrons appears inside the electron gun. This leads to a decrease in the gun perveance. To avoid this problem, the adiabatic high perveance electron gun with the clearing control electrode is designed in JINR (J. Bosser, Y. Korotaev, I. Meshkov, E. Syresin et al., Nucl. Instr. and Meth. A 391 (1996) 103. Yu. Korotaev, I. Meshkov, A. Sidorin, A. Smirnov, E. Syresin, The generation of electron beams with perveance of 3-6 μA/V 3/2 , Proceedings of SCHEF'99). The clearing control electrode has a transverse electric field, which clears secondary electrons. Computer simulations of the potential map were made with RELAX3D computer code (C.J. Kost, F.W. Jones, RELAX3D User's Guide and References Manual)

  16. High perveance electron gun for the electron cooling system

    CERN Document Server

    Korotaev, Yu V; Petrov, A; Sidorin, A; Smirnov, A; Syresin, E M; Titkova, I

    2000-01-01

    The cooling time in the electron cooling system is inversely proportional to the beam current. To obtain high current of the electron beam the control electrode of the gun is provided with a positive potential and an electrostatic trap for secondary electrons appears inside the electron gun. This leads to a decrease in the gun perveance. To avoid this problem, the adiabatic high perveance electron gun with the clearing control electrode is designed in JINR (J. Bosser, Y. Korotaev, I. Meshkov, E. Syresin et al., Nucl. Instr. and Meth. A 391 (1996) 103. Yu. Korotaev, I. Meshkov, A. Sidorin, A. Smirnov, E. Syresin, The generation of electron beams with perveance of 3-6 mu A/V sup 3 sup / sup 2 , Proceedings of SCHEF'99). The clearing control electrode has a transverse electric field, which clears secondary electrons. Computer simulations of the potential map were made with RELAX3D computer code (C.J. Kost, F.W. Jones, RELAX3D User's Guide and References Manual).

  17. Voltage-pulse generator for electron gun

    International Nuclear Information System (INIS)

    Korenev, S.A.; Enchevich, I.B.; Mikhov, M.K.

    1987-01-01

    A voltage-pulse generator with combined capacitive and inductive storage devices of an electron gun is described. The current interrupter is a hydrogen thyratron (TGI1-100/8, TGI1-500/16, or TGI1-1000/25) installed in a short magnetic lens. The current interruption time of the thyratrons is 100-300 nsec. When the capacitive storage device is charged to 1 kV, a voltage pulse with an amplitude of 25 kV is obtained at the load

  18. Electron gun simulation with CST PARTICLE STUDIO

    International Nuclear Information System (INIS)

    Spachmann, Holger; Becker, Ulrich

    2006-01-01

    This paper introduces CST PARTICLE STUDIO TM , a specialist tool for the fast and accurate design and analysis of 3D electron guns. The new software is based on the multi-purpose electromagnetic solvers of the CST STUDIO family and incorporates their powerful modelling capabilities as well as successful algorithms of the MAFIA-TS simulators. The underlying theory of the PBA based field solvers and the used tracking technique is presented and some examples of application demonstrate the current status of the software

  19. Development of beam diagnostic devices for characterizing electron guns

    International Nuclear Information System (INIS)

    Bhattacharjee, D.; Tiwari, R.; Jayaprakash, D.; Mishra, R.L.; Sarukte, H.; Waghmare, A.; Thakur, N.; Dixit, K.P.

    2015-01-01

    The electron guns for the DC accelerators and RF Linacs are designed and developed at EBC/APPD/BARC, Kharghar. These electron guns need to be characterized for its design and performance. Two test benches were developed for characterizing the electron guns. Various beam diagnostic devices for measuring beam currents and beam sizes were developed. Conical faraday cup, segmented faraday cup, slit scanning bellows movement arrangement, multi-plate beam size measurement setup, multi- wire beam size measurement setup, Aluminum foil puncture assembly etc. were developed and used. The paper presents the in-house development of various beam diagnostics for characterizing electron guns and their use. (author)

  20. Design of triode electron gun for electron LINAC

    International Nuclear Information System (INIS)

    Prasad, M.; Pande, S.A.; Hannurkar, P.R.

    2003-01-01

    A 10 MeV, 10 kW, electron linear accelerator is being developed at Centre for Advanced Technology, CAT for irradiation of agricultural products such as onions and potatoes. This facility required electron beam of variable energy and power. The linac structure consists of a thermionic triode gun, TW buncher and accelerator waveguide, focusing and centering coils, beam scanning system etc. The accelerator structure is disk loaded waveguide operating in TW 27π/3 mode at 2856 MHz. The triode gun is designed for operation at 50 kV. The gun is optimized for minimum grid voltage and minimum transverse beam dimensions. In this paper, the results of our optimization studies using computer code EGUN are presented. (author)

  1. Research and design of electron gun of electrocurtain

    International Nuclear Information System (INIS)

    Chen Pengfei; Zhang Mingchao; Li Xinmin; Wang Yuhong

    1998-01-01

    The characteristics of the electron beam current transport in the electron gun of the electrocurtain accelerator were studied and the origin of the influence on longitudinal uniformity of beam current was analysed. The deflection of the cathode is considered under the boundary condition of perfect constraint. Then a newly designed electron gun is introduced with longitudinal uniformity of current within +-10%

  2. Study and realization of an electron gun at low energy

    International Nuclear Information System (INIS)

    Camus, P.

    1977-01-01

    This work presents the theoretical concepts and experimental design of an electron gun. This gun is working in the weak energy range and the focus position is independant of electron energy measurements and analysis methods of the electron beam are described [fr

  3. Revised theory of Pierce-type electron guns

    International Nuclear Information System (INIS)

    Sar-El, H.Z.

    1982-01-01

    Attempts to date to obtain the shape of the beam forming electrodes of various Pierce-type electron guns are briefly discussed with emphasis on the many discrepansis in the results of previous works. A revised theory of Pierce-type electron guns is proposed. The shapes of the beam-forming electrodes for all known configurations of Pierce guns were computed on the basis of the proposed theory. (orig.)

  4. Technological guns which form the profiled electron beans

    International Nuclear Information System (INIS)

    Mel'nik, V.I.

    1998-01-01

    Electron guns with high-voltage glow discharge are developed which form disc - and tubule-like,hollow conic and linear electron beams,as well as devices and systems for control of gun parameter and technological processes in low and intermediate vacuum

  5. Recent advances in high-brightness electron guns at AES

    International Nuclear Information System (INIS)

    Bluem, H.; Todd, A.M.M.; Cole, M.D.; Rathke, J.; Schultheiss, T.

    2003-01-01

    We describe a number of active Advanced Energy Systems projects pertaining to the development of advanced, high-brightness electron guns for various applications. These projects include a fully superconducting, CW RF gun, nearing test, that utilizes the niobium surface as the photocathode material. An integrated 100 mA, low emittance DC/SRF gun, ideal as an injector for ERL-type light sources and intended as the injector for a 100 kW FEL, is in late design stage. A parallel high-power, CW, normal-conducting L-band RF gun project has just begun. The early performance analysis for this gun also shows good promise as an injector for ERL-type light sources. Lastly, a fully axisymmetric RF gun, operating in X-band, is being studied as a source of extremely bright electron bunches

  6. Analysis on a electron gun for metal fusion

    International Nuclear Information System (INIS)

    Paes, A.C.J.; Galvao, R.M.O.; Boscolo, P.; Passaro, A.

    1987-09-01

    The characteristics of the electron beam of the HK-011600 Δ, electron gun for metal fusion at the 'Divisao de Materiais do Instituto de Pesquisa e Desenvolvimento do CTA (PMR/IPD/CTA)', is analyzed. In this analysis, the Pierce gun model and the SLAC computational code for electron optics are used. The electron beam R and Z profiles are obtained in the gun region and in the magnetic lenses region. The behaviour of the electron beam in the prism region is also discussed using a simple model. (author) [pt

  7. A high current electron gun for the IEAv linac

    International Nuclear Information System (INIS)

    Muraro, A. Jr.; Stopa, C.R.S.; Romao, B.M.V.; Jorge, A.M.; Takahashi, J.

    2001-01-01

    This work presents the design, construction and characterization of a new electron gun for the linear electron accelerator (linac) which is under construction at the Instituto de Estudos Avancados (IEAv)

  8. Performance of the Antares large area cold cathode electron gun

    International Nuclear Information System (INIS)

    Rosocha, L.A.; Mansfield, C.R.

    1983-01-01

    The performance of the electron gun which supplies ionization for the Antares high-power electron-beam-sustained CO 2 -laser power amplifier is described. This electron gun is a coaxial cylindrical cold cathode vacuum triode having a total electron aperture area of approximately 9 m 2 . Electrons are extracted from the gun in pulses of 3 to 6 μs duration, average current densities of 40 to 60 mA/cm 2 , and electron energies of 450 to 500 keV. The main areas of discussion in this paper are the performance in terms of grid control, current-density balance, and current runaway due to breakdown limitations. Comparison of the experimental results with the predictions of a theoretical model for the electron gun are also presented

  9. Performance of the Antares large area cold cathode electron gun

    International Nuclear Information System (INIS)

    Rosocha, L.A.; Mansfield, C.R.

    1983-01-01

    The performance of the electron gun which supplies ionization for the Antares high power electron beam sustained CO 2 laser power amplifier is described. This electron gun is a coaxial cylindrical cold cathode vacuum triode having a total electron aperture area of approximately 9 m 2 . Electrons are extracted from the gun in pulses of 3-6 μs duration, average current densities of 40-60 ma/cm2, and electron energies of 450-500 keV. The main areas of discussion in this paper are the performance in terms of grid control, current density balance, and current runaway due to breakdown limitations. Comparison of the experimental results with the predictions of a theoretical model for the electron gun will also be presented

  10. Emittance growth in laser-driven RF electron guns

    International Nuclear Information System (INIS)

    Kim, K.J.

    1989-01-01

    A simple analysis for the evolution of the electron-beam phase space distribution in laser-driven rf guns is presented. In particular, formulas are derived for the transverse and longitudinal emittances at the exit of the gun. The results are compared and found to agree well with those from simulation. (Author). 9 refs.; 4 figs

  11. Generation of femtosecond electron single pulse using laser photocathode RF gun

    Energy Technology Data Exchange (ETDEWEB)

    Uesaka, M.; Kinoshita, K.; Watanabe, T. [Nuclear Engineering Research Laboratory, University of Tokyo, Tokai, Ibaraki (JP)] [and others

    1998-11-01

    A new laser photocathode RF electron gun was installed in the second linac of the S-band twin linac system of Nuclear Engineering Research Laboratory(NERL) of University of Tokyo in August in 1997. Since then, the behavior of the new gun has been tested and the characteristic parameters have been evaluated. At the exit of the gun, the energy is 4.7 MeV, the charge per bunch 1 nC, the pulse width is 10 ps(FWHM), respectively, for 6 MW RF power supply from a klystron. The electron bunch is accelerated up to 17 MeV. The horizontal normalized emittance is 1 {pi} mm.mrad. Then, the bunch is compressed to be 440 fs(FWHM) with 0.35 nC by the chicane-type magnetic pulse compressor. The gun is planned to be used for femtosecond X-ray generation via the head-on Thomson scattering and laser wakefield acceleration in 1998. (author)

  12. Design studies on high current and grid control electron gun

    International Nuclear Information System (INIS)

    Wang Jinnan; Lu Kun; Chi Yunlong; Zhou Zusheng

    2011-01-01

    Electron gun, the source of electrons, is a kind of ultrahigh vacuum device and plays an important role in different kind of accelerators. With the irradiation accelerator demands, describes the design studies on beam optics optimization. The simulation result shows that the beam current is above 5 A with cathode voltage of 80 kV and beam emittance, gun electric field and beam waist radius meet the accelerator needs. The electron gun manufactured and installed in the test stand, the conditioning and test will be done in the near future. (authors)

  13. Development of an electron gun for high power CW electron linac (1). Beam experiment for basic performance of electron gun

    International Nuclear Information System (INIS)

    Yamazaki, Yoshio; Nomura, Masahiro; Komata, Tomoki

    1999-05-01

    Presently, the Beam Group of Oarai Engineering Center in Japan Nuclear Cycle Development Institute (JNC) completed the high power CW electron linac. Then we started full-scale beam experiments after the government permission for a radiation equipment had given last January. Measurements of basic performance for the mesh-grid type electron gun have been done to launch stable beam at 300 mA peak current downstream of the accelerator. These experiments disclosed to increase beam loss in the electron gun in some cases of voltage supplied the mesh-grid in spite of same beam current from gun. Consequently, we could find the best condition for mesh-grid voltage and heater current to supply stable beam at 300 mA peak current for accelerator study. (author)

  14. The structural design and the electron optics of a hybrid electron-ion gun

    International Nuclear Information System (INIS)

    Bas, E.B.; Gisler, E.; Stucki, F.

    1984-01-01

    This paper describes a new kind of a particle gun called the hybrid gun. It is able to deliver a finely focused electron or ion beam simply by reversing the polarity of the acceleration voltage. The detailed design features of the gun are given and the electron-ion optical properties are discussed. (author)

  15. Electron gun design for HIRFL-CSR electron cooler

    International Nuclear Information System (INIS)

    Rao Yinong; Xia Jiawen; Yuan Youjin; Wei Baowen

    1996-01-01

    Adiabatic acceleration is employed to design the electron gun of HIRFL-CSR e-cooler by using the modified EGUN code. The electron beam transverse temperature variations with anode region and acceleration tube design parameters as well as the uniform solenoidal magnetic field are presented. Transversal temperature of less than 0.1 eV at a maximum current density of 0.244 A/cm 2 are obtained over the full energy range of 2.75∼165 keV

  16. Simulation of electron beam from two strip electron guns and control of power density by rotation of gun

    International Nuclear Information System (INIS)

    Sahu, G K; Baruah, S; Thakur, K B

    2012-01-01

    Electron beam is preferably used for large scale evaporation of refractory materials. Material evaporation from a long and narrow source providing a well collimated wedge shaped atomic beam has applications in isotopic purification of metals relevant to nuclear industry. The electron beam from an electron gun with strip type filament provides a linear heating source. However, the high power density of the electron beam can lead to turbulence of the melt pool and undesirable splashing of molten metal. For obtaining quiet surface evaporation, the linear electron beam is generally scanned along its length. To further reduce the power density to maintain quiet evaporation the width of the vapour source can be controlled by rotating the electron gun on its plane, thereby scanning an inclined beam over the molten pool. The rotation of gun has further advantages. When multiple strip type electron guns are used for scaling up evaporation length, a dark zone appears between two beams due to physical separation of adjacent guns. This dark zone can be reduced by rotating the gun and thereby bringing two adjacent beams closer. The paper presented here provides the simulation results of the electron beam trajectory and incident power density originating from two strip electron guns by using in-house developed code. The effect of electron gun rotation on the electron beam trajectory and power density is studied. The simulation result is experimentally verified with the image of molten pool and heat affected zone taken after experiment. This technique can be gainfully utilized in controlling the time averaged power density of the electron beam and obtaining quiet evaporation from the metal molten pool.

  17. Note: Characteristic beam parameter for the line electron gun

    Science.gov (United States)

    Iqbal, M.; Islam, G. U.; Zhou, Z.; Chi, Y.

    2013-11-01

    We have optimized the beam parameters of line source electron gun using Stanford Linear Accelerator Centre electron beam trajectory program (EGUN), utilizing electrostatic focusing only. We measured minimum beam diameter as 0.5 mm that corresponds to power density of 68.9 kW/cm2 at 13.5 mm in the post-anode region which is more than two-fold (33 kW/cm2), of the previously reported results. The gun was operated for the validation of the theoretical results and found in good agreement. The gun is now without any magnetic and electrostatic focusing thus much simpler and more powerful.

  18. Note: Characteristic beam parameter for the line electron gun

    Energy Technology Data Exchange (ETDEWEB)

    Iqbal, M. [Centre for High Energy Physics, University of the Punjab, Lahore 45590 (Pakistan); Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Islam, G. U. [Centre for High Energy Physics, University of the Punjab, Lahore 45590 (Pakistan); Zhou, Z.; Chi, Y. [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China)

    2013-11-15

    We have optimized the beam parameters of line source electron gun using Stanford Linear Accelerator Centre electron beam trajectory program (EGUN), utilizing electrostatic focusing only. We measured minimum beam diameter as 0.5 mm that corresponds to power density of 68.9 kW/cm{sup 2} at 13.5 mm in the post-anode region which is more than two-fold (33 kW/cm{sup 2}), of the previously reported results. The gun was operated for the validation of the theoretical results and found in good agreement. The gun is now without any magnetic and electrostatic focusing thus much simpler and more powerful.

  19. Note: Characteristic beam parameter for the line electron gun

    International Nuclear Information System (INIS)

    Iqbal, M.; Islam, G. U.; Zhou, Z.; Chi, Y.

    2013-01-01

    We have optimized the beam parameters of line source electron gun using Stanford Linear Accelerator Centre electron beam trajectory program (EGUN), utilizing electrostatic focusing only. We measured minimum beam diameter as 0.5 mm that corresponds to power density of 68.9 kW/cm 2 at 13.5 mm in the post-anode region which is more than two-fold (33 kW/cm 2 ), of the previously reported results. The gun was operated for the validation of the theoretical results and found in good agreement. The gun is now without any magnetic and electrostatic focusing thus much simpler and more powerful

  20. Note: Characteristic beam parameter for the line electron gun.

    Science.gov (United States)

    Iqbal, M; Islam, G U; Zhou, Z; Chi, Y

    2013-11-01

    We have optimized the beam parameters of line source electron gun using Stanford Linear Accelerator Centre electron beam trajectory program (EGUN), utilizing electrostatic focusing only. We measured minimum beam diameter as 0.5 mm that corresponds to power density of 68.9 kW/cm(2) at 13.5 mm in the post-anode region which is more than two-fold (33 kW/cm(2)), of the previously reported results. The gun was operated for the validation of the theoretical results and found in good agreement. The gun is now without any magnetic and electrostatic focusing thus much simpler and more powerful.

  1. Development of laser heated high current DC electron gun

    International Nuclear Information System (INIS)

    Banerjee, Srutarshi; Bhattacharjee, Dhruva; Kandaswamy, E.; Ghodke, S.R.; Tiwari, Rajnish; Bakhtsingh, R.I.

    2015-01-01

    The paper deals with the development of a Laser heated cathode for Electron Accelerator. The electron gun is meant for Megawatt-class DC Accelerator for Electron Beam Flue Gas Treatment applications. Conventionally, LaB 6 cathode is indirectly heated by tungsten filaments whereas in the newly proposed gun, Laser is utilized for heating. A Nd:YAG Laser is used to heat the LaB 6 cathode to emission temperatures. The characterization of cathode heating at various Laser powers has been carried out. In initial trials, it has been observed that with 125 W of Laser power, the LaB 6 pellet was heated to 1315 ° C. Based on these experimental results, an electron gun rated for 30 kV, 350 mA CW has been designed. The optimization of gun electrode geometry has been done using CST Particle Studio in order to tune the various electron gun parameters. The beam diameter obtained in simulation is 8 mm at 100 mm from the LaB 6 cathode. The perveance obtained is 7.1 x 10 -8 A/V 3/2 . The Laser heated cathode has the advantages of eliminating the magnetic field effects of filament on the electron beam, electrical isolation needed for gun filament power supplies and better electron beam emittances. (author)

  2. Low Emittance Guns for the ILC Polarized Electron Beam

    International Nuclear Information System (INIS)

    Clendenin, J. E.; Brachmann, A.; Ioakeimidi, K.; Kirby, R. E.; Maruyama, T.; Miller, R. H.; Wang, J. W.; Zhou, F.

    2007-01-01

    Polarized electron beams generated by DC guns are routinely available at several accelerators including JLAB, Mainz and SLAC. These guns operate with a cathode bias on the order of -100 kV. To minimize space charge effects, relatively long bunches are generated at the gun and then compressed longitudinally external to the gun just before and during initial acceleration. For linear colliders, this compression is accomplished using a combination of rf bunchers. For the basic design of the International Linear Collider (ILC), a 120 kV DC photocathode gun is used to produce a series of nanosecond bunches that are each compressed by two sub-harmonic bunchers (SHBs) followed by an L-band buncher and capture section. The longitudinal bunching process results in a significantly higher emittance than produced by the gun alone. While high-energy experiments using polarized beams are not generally sensitive to the source emittance, there are several benefits to a lower source emittance including a simpler more efficient injector system and a lower radiation load during transport especially at bends as at the damping ring. For the ILC, the SHBs could be eliminated if the voltage of the gun is raised sufficiently. Simulations using the General Particle Tracer (GPT) package indicate that a cathode bias voltage of ≥200 kV should allow both SHBs to be operated at 433 or even 650 MHz, while ≥500 kV would be required to eliminate the SHBs altogether. Simulations can be used to determine the minimum emittance possible if the injector is designed for a given increased voltage. A possible alternative to the DC gun is an rf gun. Emittance compensation, routinely used with rf guns, is discussed for higher-voltage DC guns

  3. Low Emittance Guns for the ILC Polarized Electron Beam

    International Nuclear Information System (INIS)

    Clendenin, J.E.; Brachmann, A.; Ioakeimidi, K.; Kirby, R.E.; Maruyama, T.; Miller, R.H.; Wang, J.W.; Zhou, F.; SLAC

    2006-01-01

    Polarized electron beams generated by DC guns are routinely available at several accelerators including JLAB, Mainz and SLAC. These guns operate with a cathode bias on the order of -100 kV. To minimize space charge effects, relatively long bunches are generated at the gun and then compressed longitudinally external to the gun just before and during initial acceleration. For linear colliders, this compression is accomplished using a combination of rf bunchers. For the basic design of the International Linear Collider (ILC), a 120 kV DC photocathode gun is used to produce a series of nanosecond bunches that are each compressed by two sub-harmonic bunchers (SHBs) followed by an L-band buncher and capture section. The longitudinal bunching process results in a significantly higher emittance than produced by the gun alone. While high-energy experiments using polarized beams are not generally sensitive to the source emittance, there are several benefits to a lower source emittance including a simpler more efficient injector system and a lower radiation load during transport especially at bends as at the damping ring. For the ILC, the SHBs could be eliminated if the voltage of the gun is raised sufficiently. Simulations using the General Particle Tracer (GPT) package indicate that a cathode bias voltage of (ge)200 kV should allow both SHBs to be operated at 433 or even 650 MHz, while (ge)500 kV would be required to eliminate the SHBs altogether. Simulations can be used to determine the minimum emittance possible if the injector is designed for a given increased voltage. A possible alternative to the DC gun is an rf gun. Emittance compensation, routinely used with rf guns, is discussed for higher-voltage DC guns

  4. An rf modulated electron gun pulser for linacs

    International Nuclear Information System (INIS)

    Legg, R.; Hartline, R.

    1991-01-01

    Present linac injector designs often make use of sub-harmonic prebuncher cavities to properly bunch the electron beam before injection into a buncher and subsequent accelerating cavities. This paper proposes an rf modulated thermionic gun which would allow the sub-harmonic buncher to be eliminated from the injector. The performance parameters for the proposed gun are 120 kV operating voltage, macropulse duration-single pulse mode 2 nsec, multiple pulse mode 100 nsec, rf modularing frequency 500 MHz, charge per micropulse 0.4 nC, macropulse repetition frequency 10 Hz (max). The gun pulser uses a grid modulated planar triode to drive the gun cathode. The grid driver takes advantage of recently developed modular CATV rf drivers, high performance solid state pulser devices, and high-frequency fiber optic transmitters for telecommunications. Design details are presented with associated SPICE runs simulating operation of the gun

  5. Finite element analyses of a linear-accelerator electron gun

    Science.gov (United States)

    Iqbal, M.; Wasy, A.; Islam, G. U.; Zhou, Z.

    2014-02-01

    Thermo-structural analyses of the Beijing Electron-Positron Collider (BEPCII) linear-accelerator, electron gun, were performed for the gun operating with the cathode at 1000 °C. The gun was modeled in computer aided three-dimensional interactive application for finite element analyses through ANSYS workbench. This was followed by simulations using the SLAC electron beam trajectory program EGUN for beam optics analyses. The simulations were compared with experimental results of the assembly to verify its beam parameters under the same boundary conditions. Simulation and test results were found to be in good agreement and hence confirmed the design parameters under the defined operating temperature. The gun is operating continuously since commissioning without any thermal induced failures for the BEPCII linear accelerator.

  6. Finite element analyses of a linear-accelerator electron gun

    Energy Technology Data Exchange (ETDEWEB)

    Iqbal, M., E-mail: muniqbal.chep@pu.edu.pk, E-mail: muniqbal@ihep.ac.cn [Centre for High Energy Physics, University of the Punjab, Lahore 45590 (Pakistan); Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Wasy, A. [Department of Mechanical Engineering, Changwon National University, Changwon 641773 (Korea, Republic of); Islam, G. U. [Centre for High Energy Physics, University of the Punjab, Lahore 45590 (Pakistan); Zhou, Z. [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China)

    2014-02-15

    Thermo-structural analyses of the Beijing Electron-Positron Collider (BEPCII) linear-accelerator, electron gun, were performed for the gun operating with the cathode at 1000 °C. The gun was modeled in computer aided three-dimensional interactive application for finite element analyses through ANSYS workbench. This was followed by simulations using the SLAC electron beam trajectory program EGUN for beam optics analyses. The simulations were compared with experimental results of the assembly to verify its beam parameters under the same boundary conditions. Simulation and test results were found to be in good agreement and hence confirmed the design parameters under the defined operating temperature. The gun is operating continuously since commissioning without any thermal induced failures for the BEPCII linear accelerator.

  7. Finite element analyses of a linear-accelerator electron gun

    International Nuclear Information System (INIS)

    Iqbal, M.; Wasy, A.; Islam, G. U.; Zhou, Z.

    2014-01-01

    Thermo-structural analyses of the Beijing Electron-Positron Collider (BEPCII) linear-accelerator, electron gun, were performed for the gun operating with the cathode at 1000 °C. The gun was modeled in computer aided three-dimensional interactive application for finite element analyses through ANSYS workbench. This was followed by simulations using the SLAC electron beam trajectory program EGUN for beam optics analyses. The simulations were compared with experimental results of the assembly to verify its beam parameters under the same boundary conditions. Simulation and test results were found to be in good agreement and hence confirmed the design parameters under the defined operating temperature. The gun is operating continuously since commissioning without any thermal induced failures for the BEPCII linear accelerator

  8. Development techniques and electron optical studies of high voltage, high current electron guns

    International Nuclear Information System (INIS)

    Rangarajan, L.M.; Mahadevan, S.; Ramamurthi, S.S.

    1992-01-01

    The progress of the electron gun design, limiting to axially symmetric geometries is discussed here with a view to utilise such guns for electron accelerators. The mechanical design features leading to the physical configuration of the gun with stringent tolerances are outlined. Vacuum processing is done at pressures of 1.3x10 -5 Pa. The gun employs W-filament emitter or a cathode pellet with bombarder service. A water cooled compact faraday cup is used to measure the electron current. Electron gun geometries have been studied using the computer programme. The preveance of the gun is 0.7x10 -7 A/Vsup(1.5) at 80 kV. Developmental techniques of such pulsed electron guns are described. (author). 7 refs., 5 figs

  9. Design of a low emittance and high repetition rate S-band photoinjector

    Science.gov (United States)

    Han, Jang-Hui

    2014-09-01

    As an electron beam injector of X-ray free-electron lasers (FELs), photoinjectors have been developed for the past few decades. Such an injector starting with a photocathode RF gun provides high brightness beams and therefore it is being adopted as an injector of X-ray FELs. In this paper we show how to improve photoinjector performance in terms of emittance and repetition rates by means of injector components optimization, especially with the gun. Transverse emittance at the end of an injector is reduced by optimizing the gun design, gun solenoid position, and accelerating section position. The repetition rate of an injector mainly depends on the gun. It is discussed that a repetition rate of 1 kHz at a normal-conducting S-band photoinjector is feasible by adopting a coaxial RF coupler and improving cooling-water channels surrounding the gun.

  10. Simulations of the ILC Electron Gun and Electron Bunching System

    International Nuclear Information System (INIS)

    Haakonsen, C.B.; McGill U.

    2006-01-01

    The International Linear Collider (ILC) is a proposed electron-positron collider, expected to provide insight into important questions in particle physics. A part of the global R and D effort for the ILC is the design of its electron gun and electron bunching system. The present design of the bunching system has two sub-harmonic bunchers, one operating at 108 MHz and one at 433MHz, and two 5-cell 1.3 GHz (L-band) bunchers. This bunching system has previously been simulated using the Phase and Radial Motion in Electron Linear Accelerators (PARMELA) software, and those simulations indicated that the design provides sufficient bunching and acceleration. Due to the complicated dynamics governing the electrons in the bunching system we decided to verify and expand the PARMELA results using the more recent and independent simulation software General Particle Tracer (GPT). GPT tracks the motion and interactions of a set of macro particles, each of which represent a number of electrons, and provides a variety of analysis capabilities. To provide initial conditions for the macro particles, a method was developed for deriving the initial conditions from detailed simulations of particle trajectories in the electron gun. These simulations were performed using the Egun software. For realistic simulation of the L-band bunching cavities, their electric and magnetic fields were calculated using the Superfish software and imported into GPT. The GPT simulations arrived at similar results to the PARMELA simulations for sub-harmonic bunching. However, using GPT it was impossible to achieve an efficient bunching performance of the first L-band bunching cavity. To correct this, the first L-band buncher cell was decoupled from the remaining 4 cells and driven as an independent cavity. Using this modification we attained results similar to the PARMELA simulations. Although the modified bunching system design performed as required, the modifications are technically challenging to implement

  11. Method of electron emission control in RF guns

    International Nuclear Information System (INIS)

    Khodak, I.V.; Kushnir, V.A.

    2001-01-01

    The electron emission control method for a RF gun is considered.According to the main idea of the method,the additional resonance system is created in a cathode region where the RF field strength could be varied using the external pulse equipment. The additional resonance system is composed of a coaxial cavity coupled with a RF gun cylindrical cavity via an axial hole. Computed results of radiofrequency and electrodynamic performances of such a two-cavity system and results of the RF gun model pilot study are presented in. Results of particle dynamics simulation are described

  12. Method of electron emission control in RF guns

    CERN Document Server

    Khodak, I V

    2001-01-01

    The electron emission control method for a RF gun is considered.According to the main idea of the method,the additional resonance system is created in a cathode region where the RF field strength could be varied using the external pulse equipment. The additional resonance system is composed of a coaxial cavity coupled with a RF gun cylindrical cavity via an axial hole. Computed results of radiofrequency and electrodynamic performances of such a two-cavity system and results of the RF gun model pilot study are presented in. Results of particle dynamics simulation are described.

  13. Summary, Working Group 1: Electron guns and injector designs

    International Nuclear Information System (INIS)

    Ben-Zvi, I.; Bazarov, I.V.

    2006-01-01

    We summarize the proceedings of Working Group 1 of the 2005 Energy Recovery Linac (ERL) Workshop. The subject of this working group, the electron gun and injector design, is arguably the most critical part of the ERL as it determines the ultimate performance of this type of accelerators. Working Group 1 dealt with a variety of subjects: The technology of DC, normal-conducting RF and superconducting RF guns; beam dynamics in the gun and injector; the cathode and laser package; modeling and computational issues; magnetized beams and polarization. A short overview of these issues covered in the Working Group is presented in this paper

  14. High quality flux control system for electron gun evaporation

    International Nuclear Information System (INIS)

    Appelbloom, A.M.; Hadley, P.; van der Marel, D.; Mooij, J.E.

    1991-01-01

    This paper reports on a high quality flux control system for electron gun evaporation developed and tested for the MBE growth of high temperature superconductors. The system can be applied to any electron gun without altering the electron gun itself. Essential elements of the system are a high bandwidth mass spectrometer, control electronics and a high voltage modulator to sweep the electron beam over the melt at high frequencies. the sweep amplitude of the electron beam is used to control the evaporation flux at high frequencies. The feedback loop of the system has a bandwidth of over 100 Hz, which makes it possible to grow superlattices and layered structures in a fast and precisely controlled manner

  15. Design and fabrication of a pulsed diode electron gun

    International Nuclear Information System (INIS)

    Mahadevan, S.; Gandhi, M.L.; Nandedkar, R.V.

    2003-01-01

    A pulsed diode electron gun has been designed, fabricated and tested and this will be used for the initial hot testing of the Plane Wave Transformer (PWT) linac. The gun is required to deliver 1 A at 70 kV which works out to a current of 500 mA at 40 kV. The gun geometry is optimized using the Electron Trajectory Program EGUN at a mesh size of 0.2 mm. The beam divergence close to cathode caused by an annular gap of 2 mm between cathode and focusing electrode (FE) is compensated by using a suitable focusing electrode. Important features of the pulsed power supply (40 kV, 500 mA, 2 μsec) developed for testing this gun are presented. The current measured at the Faraday cup is in agreement with the designed perveance. Suitable positioning of cathode with respect to the FE helps in further improving the beam quality

  16. The system of RF beam control for electron gun

    International Nuclear Information System (INIS)

    Barnyakov, A.M.; Levichev, A.E.; Chernousov, Yu.D.; Ivannikov, V.I.; Shebolaev, I.V.

    2015-01-01

    The system of RF control of three-electrode electron gun current is described. It consists of a source of microwave signal, coaxial line, coaxial RF switch and RF antenna lead. The system allows one to get the electron beam in the form of bunches with the frequency of the accelerating section to achieve the capture of particles in the acceleration mode close to 100%. The results of calculation and analysis of the elements of the system are presented. Characteristics of the devices are obtained experimentally. The results of using RF control in three-electrode electron gun at electron linear accelerator are described

  17. Plasma wave observations during electron and ion gun experiments

    International Nuclear Information System (INIS)

    Olsen, R.C.; Lowery, D.R.; Weddle, L.E.

    1988-01-01

    Plasma wave instruments with high temporal and frequency resolution in the 0-6 kHz frequency range have been used to monitor electron gun-employing charge control experiments with the USAF/NASA p78-2 satellite, in order to determine whether plasma wave signatures consistent with the previous inference of electron heating were present. Strong plasma waves were noted near the electron gyrofrequency; these waves can heat ambient low energy electrons, as previously inferred. Attention is given to the two distinct classes of behavior revealed by the ion gun experiments. 16 references

  18. Theoretical investigation of an electron gun with a point cathode

    International Nuclear Information System (INIS)

    Rauh, H.; Kern, D.

    1978-01-01

    Electron-optical properties of a gun with a point cathode are determined numerically by tracing a greater number of electron trajectories. In order to calculate the beam current density distribution, an attempt was made to describe the properties of the gun in terms of the parameters describing the inital conditions of the trajectories. Contrary to the conventional electron-optical imaging theory, the electron gun under consideration cannot be sufficiently characterized by a few aberration coefficients, since only a small fraction of the trajectories forming the electron beam would be covered by an expansion containing linear, third and fifth order terms so that the series expansion method is not applicable. (orig.) 891 WBU [de

  19. A novel electron gun for inline MRI-linac configurations

    International Nuclear Information System (INIS)

    Constantin, Dragoş E.; Fahrig, Rebecca; Holloway, Lois; Keall, Paul J.

    2014-01-01

    Purpose: This work introduces a new electron gun geometry capable of robust functioning in the presence of a high strength external magnetic field for axisymmetric magnetic resonance imaging (MRI)-linac configurations. This allows an inline MRI-linac to operate without the need to isolate the linear accelerator (linac) using a magnetic shield. This MRI-linac integration approach not only leaves the magnet homogeneity unchanged but also provides the linac flexibility to move along the magnet axis of symmetry if the source to target distance needs to be adjusted. Methods: Simple electron gun geometry modifications of a Varian 600C electron gun are considered and solved in the presence of an external magnetic field in order to determine a set of design principles for the new geometry. Based on these results, a new gun geometry is proposed and optimized in the fringe field of a 0.5 T open bore MRI magnet (GE Signa SP). A computer model for the 6 MeV Varian 600C linac is used to determine the capture efficiency of the new electron gun-linac system in the presence of the fringe field of the same MRI scanner. The behavior of the new electron gun plus the linac system is also studied in the fringe fields of two other magnets, a 1.0 T prototype open bore magnet and a 1.5 T GE Conquest scanner. Results: Simple geometrical modifications of the original electron gun geometry do not provide feasible solutions. However, these tests show that a smaller transverse cathode diameter with a flat surface and a slightly larger anode diameter could alleviate the current loss due to beam interactions with the anode in the presence of magnetic fields. Based on these findings, an initial geometry resembling a parallel plate capacitor with a hole in the anode is proposed. The optimization procedure finds a cathode-anode distance of 5 mm, a focusing electrode angle of 5°, and an anode drift tube length of 17.1 mm. Also, the linac can be displaced with ±15 cm along the axis of the 0.5 T

  20. Study of the hollow cathode plasma electron-gun

    International Nuclear Information System (INIS)

    Zhang Yonghui; Jiang Jinsheng; Chang Anbi

    2003-01-01

    For developing a novel high-current, long pulse width electron source, the theoretics and mechanism of the hollow cathode plasma electron-gun are analyzed in detail in this paper, the structure and the physical process of hollow cathode plasma electron-gun are also studied. This gun overcomes the limitations of most high-power microwave tubes, which employ either thermionic cathodes that produce low current-density beams because of the limitation of the space charge, or field-emission cathodes that offer high current density but provide only short pulse width because of plasma closure of the accelerating gap. In the theories studying on hollow cathode plasma electron-gun, the characteristic of the hollow-cathode discharge is introduced, the action during the forming of plasma of the stimulating electrode and the modulating anode are discussed, the movement of electrons and ions and the primary parameters are analyzed, and the formulas of the electric field, beam current density and the stabilization conditions of the beam current are also presented in this paper. The numerical simulation is carried out based on Poisson's equation, and the equations of current continuity and movement. And the optimized result is reported. On this basis, we have designed a hollow-cathode-plasma electron-gun, whose output pulse current is 2 kA, and pulse width is 1 microsecond

  1. A Compact 5 MeV S-Band Electron Linac Based X-Ray Source for Industrial Radiography

    CERN Document Server

    Auditore, Lucrezia; De Pasquale, Domenico; Emanuele, Umberto; Italiano, Antonio; Trifirò, Antonio; Trimarchi, Marina

    2005-01-01

    A compact and reliable X-ray source, based on a 5 MeV, 1 kW, S-band electron linac, has been set up at the Dipartimento di Fisica, Universit\\'a di Messina. This source, coupled with a GOS scintillator screen and a CCD camera, represents an innovative transportable system for industrial radiography and X-ray tomography. Optimization of the parameters influencing the e-gamma conversion and the X-ray beam characteristics have been studied by means of the MCNP-4C2 code. The converter choice is the result of the study of the e-gamma conversion performances for different materials and materials thicknesses. Also the converter position with respect to the linac exit window was studied. The chosen converter consists in a Ta-Cu target inserted close to the linac window. The Cu layer acts as a filter both on the electrons from the source and on the low energy X-rays. The X-ray beam angular profile was studied by means of GafChromic films with and without collimation. In the final source project, a collimation system pr...

  2. Design and remote fiber communication of NSRL electron gun controller

    International Nuclear Information System (INIS)

    Wang Weibing; Gao Hui; Hong Jun; Chen Jun; Wang Guicheng; He Duohui; Chen Gang

    2005-01-01

    A new kind of pulse electron gun controller for 200 MeV LINAC at National Synchrotron Radiation Laboratory was introduced in this paper, including the working principle of the pulse electron gun, the applications of I 2 C serial bus and embedded microcontroller in controlling system. The emphasis is on the hardware design of digital controlled current regulator, digital controlled switch voltage source and high voltage pulse power supply. The software design of fiber communication and PC controlling is also presented. The electron gun controller has successfully been used in NSRL. The result shows that it is quite reliable and the performance is good. This electronic digital system has completely replaced the old mechanical control system. (authors)

  3. A NEW THERMIONIC RF ELECTRON GUN FOR SYNCHROTRON LIGHT SOURCES

    Energy Technology Data Exchange (ETDEWEB)

    Kutsaev, Sergey; Agustsson, R.; Hartzell, J; Murokh, A.; Nassiri, A.; Savin, E.; Smirnov, A.V.; Smirnov, A. Yu; Sun, Y.; Verma, A; Waldschmidt, Geoff; Zholents, A.

    2017-06-02

    A thermionic RF gun is a compact and efficient source of electrons used in many practical applications. RadiaBeam Systems and the Advanced Photon Source at Argonne National Laboratory collaborate in developing of a reliable and robust thermionic RF gun for synchrotron light sources which would offer substantial improvements over existing thermionic RF guns and allow stable operation with up to 1A of beam peak current at a 100 Hz pulse repetition rate and a 1.5 μs RF pulse length. In this paper, we discuss the electromagnetic and engineering design of the cavity and report the progress towards high power tests of the cathode assembly of the new gun.

  4. High voltage processing of the SLC polarized electron gun

    International Nuclear Information System (INIS)

    Saez, P.; Clendenin, J.; Garden, C.; Hoyt, E.; Klaisner, L.; Prescott, C.; Schultz, D.; Tang, H.

    1993-04-01

    The SLC polarized electron gun operates at 120 kV with very low dark current to maintain the ultra high vacuum (UHV). This strict requirement protects the extremely sensitive photocathode from contaminants caused by high voltage (HV) activity. Thorough HV processing is thus required x-ray sensitive photographic film, a nanoammeter in series with gun power supply, a radiation meter, a sensitive residual gas analyzer and surface x-ray spectrometry were used to study areas in the gun where HV activity occurred. By reducing the electric field gradients, carefully preparing the HV surfaces and adhering to very strict clean assembly procedures, we found it possible to process the gun so as to reduce both the dark current at operating voltage and the probability of HV discharge. These HV preparation and processing techniques are described

  5. High-voltage pulse generator for electron gun power supply

    International Nuclear Information System (INIS)

    Korenev, S.A.; Enchevich, I.B.; Mikhov, M.K.

    1987-01-01

    High-voltage pulse generator with combined capacitive and inductive energy storages for electron gun power supply is described. Hydrogen thyratron set in a short magnetic lense is a current breaker. Times of current interruption in thyratrons are in the range from 100 to 300 ns. With 1 kV charging voltage of capacitive energy storage 25 kV voltage pulse is obtained in the load. The given high-voltage pulse generator was used for supply of an electron gun generating 10-30 keV low-energy electron beam

  6. Characterisation of 100 kW electron beam melting gun and its adaptation as electron gun for high power DC electron accelerators

    International Nuclear Information System (INIS)

    Banerjee, Srutarshi; Bhattacharjee, Dhruva; Waghmare, Abhay; Tiwari, Rajnish; Bakhtsingh, R.I.; Dasgupta, K.; Gupta, Sachin; Prakash, Baibhaw; Jha, M.N.

    2015-01-01

    The paper deals with the characterization of the 100 kW electron beam melting gun for its adaptation in high power DC Electron Accelerators. The indigenously designed electron beam melting system at BARC is chosen for characterization. It comprises of electron gun as source of electrons, two electromagnetic focusing lenses viz. upper focusing lens and lower focusing lens for beam focusing, intermediate beam aperture for vacuum decoupling between gun region and melt zone, deflection and oscillation lens for maneuvering the beam on the melt charge and water cooled crucible that acts as a beam dump. In this system, the electron gun is designed for 40 kV and 100 kW corresponding to a maximum beam current of 2.5 A. The electron gun uses directly heated spiral tungsten filament. The operating temperature of the filament is 2800 °K. The focusing electrode and the anode profile are designed based on Pierce geometry. High Power DC Electron Accelerators require high currents of 1 A. The beam must comply with the requirement of 40 mm beam diameter and 10 mrad divergence at the exit of the electron gun. The characterization of the existing electron gun was done to find out all the beam parameters, for e.g. beam size, beam divergence, perveance etc. to be adapted or to be modified for the design of electron gun for high power DC accelerators. This paper shows limitations and the possible solutions for design of high power DC accelerators. (author)

  7. Electron Gun for Computer-controlled Welding of Small Components

    Czech Academy of Sciences Publication Activity Database

    Dupák, Jan; Vlček, Ivan; Zobač, Martin

    2001-01-01

    Roč. 62, 2-3 (2001), s. 159-164 ISSN 0042-207X R&D Projects: GA AV ČR IBS2065015 Institutional research plan: CEZ:AV0Z2065902 Keywords : Electron beam-welding machine * Electron gun * Computer- control led beam Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 0.541, year: 2001

  8. Fundamentals for a terahertz-driven electron gun

    DEFF Research Database (Denmark)

    Lange, Simon Lehnskov; Olsen, Filip D.; Iwaszczuk, Krzysztof

    2017-01-01

    dipoles placed with a small gap in between. We conclude that it is possible to make ultra-bright electron bunches shorter than 1 ps and accelerate them to the low keV range over 15 mu m using only a single THz transient. Our results are fundamental to understand and build a THz-driven electron gun....

  9. Polarized Light Sources for photocathode electron guns at SLAC

    International Nuclear Information System (INIS)

    Woods, M.; Frisch, J.; Witte, K.; Zolotorev, M.

    1992-12-01

    We describe current and future Polarized Light Sources at SLAC for use with photocathode electron guns to produce polarized electron beams. The SLAC experiments SLD and E142 are considered, and are used to define the required parameters for the Polarized Light Sources

  10. Development of Field-Emission Electron Gun from Carbon Nanotubes

    CERN Document Server

    Hozumi, Y

    2004-01-01

    Aiming to use a narrow energy-spread electron beam easily and low costly on injector electron guns, we have been tested field emission cathodes of carbon nanotubes (CNTs). Experiments for these three years brought us important suggestions and a few rules of thumb. Now at last, anode current of 3.0 [A/cm2

  11. Virtual cathode driven by short pulse electron gun

    Energy Technology Data Exchange (ETDEWEB)

    Spassovsky, I P; Cho, Sung Oh; Lee, Jongmin; Lee, Byung-Cheol; Jeong, Young Uk [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of). Laboratory for Quantum Optics; Messina, G [ENEA, Roma-Frascati (Italy). INN-FIS-LAC; Yovchev, I G; Nikolov, N A [Sofia Univ. (Bulgaria). Faculty of Physics

    1997-12-31

    An electron gun has been developed by ENEA (Italy) to power a free-electron laser operating in the far infrared region. The device can also be used to drive various microwave sources. Numerical simulations were performed for the planned foil-diode vircator experiment to be carried out by ENEA. (author). 5 figs., 4 refs.

  12. Virtual cathode driven by short pulse electron gun

    International Nuclear Information System (INIS)

    Spassovsky, I.P.; Cho, Sung Oh; Lee, Jongmin; Lee, Byung-Cheol; Jeong, Young Uk; Messina, G.; Yovchev, I.G.; Nikolov, N.A.

    1996-01-01

    An electron gun has been developed by ENEA (Italy) to power a free-electron laser operating in the far infrared region. The device can also be used to drive various microwave sources. Numerical simulations were performed for the planned foil-diode vircator experiment to be carried out by ENEA. (author). 5 figs., 4 refs

  13. A high voltage test stand for electron gun qualification for LINACs

    International Nuclear Information System (INIS)

    Wanmode, Yashwant D.; Mulchandani, J.; Acharya, M.; Bhisikar, A.; Singh, H.G.; Shrivastava, Purushottam

    2011-01-01

    An electron gun lest stand has been developed at RRCAT. The test stand consists of a high voltage pulsed power supply, electron gun filament supply, grid supply, UHV system and electron gun current measurement system. Several electron guns developed indigenously were evaluated on this test stand. The shielding is provided for the electron gun set up. Electron gun tests can be tested upto 55 kV with pulse width of 15 microsecs and pulse repetition rates up to 200 Hz. The technical details of the subsystems are furnished and results of performance of the test stand have been reported in this paper. (author)

  14. A design study of non-adiabatic electron guns

    International Nuclear Information System (INIS)

    Barroso, J.J.; Stellati, C.

    1994-01-01

    The design of a non-adiabatic gun capable of producing a 10 A, 50 KeV high-quality laminar electron beam is reported. In contrast to the magnetron injection gun with a conical cathode, where the beam is generated initially with a transverse velocity component, in the non-adiabatic gun electrons are extracted in a direction parallel to the axial guide magnetic field. The beam electrons acquire cyclotron motion as result of non-adiabatic processes in a strong non uniform electric field across the modulation anode. Such an extraction method gives rise to favourable features that are explored throughout the work. An extensive numerical simulation study has also been done to minimize velocity and energy spreads. (author). 3 refs, 5 figs, 1 tab

  15. Enhanced ECR ion source performance with an electron gun

    International Nuclear Information System (INIS)

    Xie, Z.; Lyneis, C.M.; Lam, R.S.; Lundgren, S.A.

    1991-01-01

    An electron gun for the advanced electron cyclotron resonance (AECR) source has been developed to increase the production of high charge state ions. The AECR source, which operates at 14 GHz, is being developed for the 88-in. cyclotron at Lawrence Berkeley Laboratory. The electron gun injects 10 to 150 eV electrons into the plasma chamber of the AECR. With the electron gun the AECR has produced at 10 kV extraction voltage 131 e μA of O 7+ , 13 e μA of O 8+ , 17 e μA of Ar 14+ , 2.2 e μA of Kr 25+ , 1 e μA of Xe 31+ , and 0.2 e μA of Bi 38+ . The AECR was also tested as a single stage source with a coating of SiO 2 on the plasma chamber walls. This significantly improved its performance compared to no coating, but direct injection of electrons with the electron gun produced the best results

  16. Fabrication and description of a cold cathode electron gun

    International Nuclear Information System (INIS)

    Sari, A.H.; Ghorannevis, M.; Hantehzadeh, M.R.; Yousefi, M.R.

    2003-01-01

    In this study the structure and schematic configuration of a cold cathode electron gun has been shown, which use obstructed discharge for electron producing. This type of discharge and mechanism of secondary electron emission by ions and fast neutral interaction have been described. The experiment starts in pressure of 1*10 -3 torr, in existence of helium gas. A negative DC voltage apply to a concave cathode up to -20 k V which determine electron energy

  17. A cusp electron gun for millimeter wave gyrodevices

    Science.gov (United States)

    Donaldson, C. R.; He, W.; Cross, A. W.; Li, F.; Phelps, A. D. R.; Zhang, L.; Ronald, K.; Robertson, C. W.; Whyte, C. G.; Young, A. R.

    2010-04-01

    The experimental results of a thermionic cusp electron gun, to drive millimeter and submillimeter wave harmonic gyrodevices, are reported in this paper. Using a "smooth" magnetic field reversal formed by two coils this gun generated an annular-shaped, axis-encircling electron beam with 1.5 A current, and an adjustable velocity ratio α of up to 1.56 at a beam voltage of 40 kV. The beam cross-sectional shape and transported beam current were measured by a witness plate technique and Faraday cup, respectively. These measured results were found to be in excellent agreement with the simulated results using the three-dimensional code MAGIC.

  18. OPTIMIZATION OF OPERATION PARAMETERS OF 80-KEV ELECTRON GUN

    Directory of Open Access Journals (Sweden)

    JEONG DONG KIM

    2014-06-01

    As a first step, the electron generator of an 80-keV electron gun was manufactured. In order to produce the high beam power from electron linear accelerator, a proper beam current is required form the electron generator. In this study, the beam current was measured by evaluating the performance of the electron generator. The beam current was determined by five parameters: high voltage at the electron gun, cathode voltage, pulse width, pulse amplitude, and bias voltage at the grid. From the experimental results under optimal conditions, the high voltage was determined to be 80 kV, the pulse width was 500 ns, and the cathode voltage was from 4.2 V to 4.6 V. The beam current was measured as 1.9 A at maximum. These results satisfy the beam current required for the operation of an electron linear accelerator.

  19. Electron gun simulation for 95 GHz gyrotron

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Udaybir; Kumar, Nitin; Sinha, A.K., E-mail: uday.ceeri@gmail.com, E-mail: aksinha@ceeri.ernet.in [Gyrotron Laboratory, Microwave Tube Area, Central Electronics Engineering Research Institute, Pilani (India); Purohit, L.P. [Department of Physics, Gurukul Kangri Vishwavidyalaya, Haridwar (India)

    2011-07-01

    A triode type Magnetron Injection Gun (MIG) for a 2 MW, 95 GHz Gyrotron has been designed by using commercially available code EGUN and another in-house developed code MIGANS. The operating mode of the gyrotron is TE{sub 24.8} and it is operated in the fundamental harmonic. The operating voltages of the modulating anode and the accelerating anode are 61 kV and 85 kV respectively. The parametric dependences of modulating anode voltage and cathode magnetic field on the beam quality have also been studied. (author)

  20. Electron gun simulation for 95 GHz gyrotron

    International Nuclear Information System (INIS)

    Singh, Udaybir; Kumar, Nitin; Sinha, A.K.; Purohit, L.P.

    2011-01-01

    A triode type Magnetron Injection Gun (MIG) for a 2 MW, 95 GHz Gyrotron has been designed by using commercially available code EGUN and another in-house developed code MIGANS. The operating mode of the gyrotron is TE 24.8 and it is operated in the fundamental harmonic. The operating voltages of the modulating anode and the accelerating anode are 61 kV and 85 kV respectively. The parametric dependences of modulating anode voltage and cathode magnetic field on the beam quality have also been studied. (author)

  1. Longitudinal Jitter Analysis of a Linear Accelerator Electron Gun

    Directory of Open Access Journals (Sweden)

    MingShan Liu

    2016-11-01

    Full Text Available We present measurements and analysis of the longitudinal timing jitter of a Beijing Electron Positron Collider (BEPCII linear accelerator electron gun. We simulated the longitudinal jitter effect of the gun using PARMELA to evaluate beam performance, including: beam profile, average energy, energy spread, and XY emittances. The maximum percentage difference of the beam parameters is calculated to be 100%, 13.27%, 42.24% and 65.01%, 86.81%, respectively. Due to this, the bunching efficiency is reduced to 54%. However, the longitudinal phase difference of the reference particle was 9.89°. The simulation results are in agreement with tests and are helpful to optimize the beam parameters by tuning the trigger timing of the gun during the bunching process.

  2. A pulsed electron gun for the Plane Wave Transformer Linac

    Science.gov (United States)

    Mahadevan, S.; Gandhi, M. L.; Nandedkar, R. V.

    2003-01-01

    A pulsed diode electron gun delivering 500 mA current at 40 kV is described. The gun geometry is optimized using the Electron Trajectory Program EGUN at higher scaling factors by choosing the closest converging starting surface. The effect of an annular gap between cathode and focusing electrode on beam behaviour is compensated by using a suitable focusing electrode. The estimated perveance is 0.065 μperv and the normalized emittance is within 5 π mm mrad. The variation in current density at the cathode has been limited to within 10% across the face of the cathode. Salient features of the pulsed power supply and an insight of its interconnection with the gun are presented. The current measured at the Faraday cup is in agreement with the designed perveance.

  3. A pulsed electron gun for the Plane Wave Transformer Linac

    Energy Technology Data Exchange (ETDEWEB)

    Mahadevan, S. E-mail: maharaja@cat.ernet.in; Gandhi, M.L. E-mail: mlg@cat.ernet.in; Nandedkar, R.V. E-mail: nrv@cat.ernet.in

    2003-01-01

    A pulsed diode electron gun delivering 500 mA current at 40 kV is described. The gun geometry is optimized using the Electron Trajectory Program EGUN at higher scaling factors by choosing the closest converging starting surface. The effect of an annular gap between cathode and focusing electrode on beam behaviour is compensated by using a suitable focusing electrode. The estimated perveance is 0.065 {mu}perv and the normalized emittance is within 5{pi} mm mrad. The variation in current density at the cathode has been limited to within 10% across the face of the cathode. Salient features of the pulsed power supply and an insight of its interconnection with the gun are presented. The current measured at the Faraday cup is in agreement with the designed perveance.

  4. A pulsed electron gun for the Plane Wave Transformer Linac

    CERN Document Server

    Mahadevan, S; Nandedkar, R V

    2003-01-01

    A pulsed diode electron gun delivering 500 mA current at 40 kV is described. The gun geometry is optimized using the Electron Trajectory Program EGUN at higher scaling factors by choosing the closest converging starting surface. The effect of an annular gap between cathode and focusing electrode on beam behaviour is compensated by using a suitable focusing electrode. The estimated perveance is 0.065 mu perv and the normalized emittance is within 5 pi mm mrad. The variation in current density at the cathode has been limited to within 10% across the face of the cathode. Salient features of the pulsed power supply and an insight of its interconnection with the gun are presented. The current measured at the Faraday cup is in agreement with the designed perveance.

  5. A pulsed electron gun for the Plane Wave Transformer Linac

    International Nuclear Information System (INIS)

    Mahadevan, S.; Gandhi, M.L.; Nandedkar, R.V.

    2003-01-01

    A pulsed diode electron gun delivering 500 mA current at 40 kV is described. The gun geometry is optimized using the Electron Trajectory Program EGUN at higher scaling factors by choosing the closest converging starting surface. The effect of an annular gap between cathode and focusing electrode on beam behaviour is compensated by using a suitable focusing electrode. The estimated perveance is 0.065 μperv and the normalized emittance is within 5π mm mrad. The variation in current density at the cathode has been limited to within 10% across the face of the cathode. Salient features of the pulsed power supply and an insight of its interconnection with the gun are presented. The current measured at the Faraday cup is in agreement with the designed perveance

  6. Upgraded G-optk program for electron gun characterization

    International Nuclear Information System (INIS)

    Nagasao, K.; Takebe, M.; Ushio, W.; Fujita, S.; Ohye, T.; Shimoyama, H.

    2011-01-01

    The generalized trajectory theory (the G-optk program) has been extended in order to make the method applicable to electron guns with curved and/or asymmetric cathodes. The object-image analysis mode has also been added. Enhanced capability of the upgraded G-optk program was demonstrated by applying the program to three electron optical systems: (a) the point cathode gun, (b) the hairpin-type cathode gun, and (c) the LEEM objective lens. The Canonical Mapping Transformation (CMT) diagrams were calculated both by direct ray tracing and by the upgraded G-optk program. In each case, it was found that the upgraded program reproduces well the results obtained by ray tracing. The generalized trajectory method has several advantages over direct ray tracing, such as substantially lighter calculation load and easy interpretation of the calculation results in terms of the optical parameters.

  7. Supply system with microprocessor control for electron gun

    International Nuclear Information System (INIS)

    Duplin, N.I.; Sergeev, N.N.

    1988-01-01

    Precision supply system for electron gun used in Auger-spectrometer is described. The supply system consists of control and high-voltage parts, made as separate units. Supply high-voltage unit includes system supply module, filament module to supply electron gun cathode and 6 high-volt modules to supply accelerating, modulating and three focusing electrodes of the gun. High-voltage modules have the following characteristics: U-(100-1000)V output voltage, 5x10 -5 U stability, 10 -5 xU pulsation amplitude, J-(0-5)A filament current change range at 10 -4 xJ stability. Control unit including microprocessor, timer and storage devices forms control voltage for all modules and regulates voltage and current of filament at electrodes

  8. Electron beam characterization of a combined diode rf electron gun

    Directory of Open Access Journals (Sweden)

    R. Ganter

    2010-09-01

    Full Text Available Experimental and simulation results of an electron gun test facility, based on pulsed diode acceleration followed by a two-cell rf cavity at 1.5 GHz, are presented here. The main features of this diode-rf combination are: a high peak gradient in the diode (up to 100  MV/m obtained without breakdown conditioning, a cathode shape providing an electrostatic focusing, and an in-vacuum pulsed solenoid to focus the electron beam between the diode and the rf cavity. Although the test stand was initially developed for testing field emitter arrays cathodes, it became also interesting to explore the limits of this electron gun with metallic photocathodes illuminated by laser pulses. The ultimate goal of this test facility is to fulfill the requirements of the SwissFEL project of Paul Scherrer Institute [B. D. Patterson et al., New J. Phys. 12, 035012 (2010NJOPFM1367-263010.1088/1367-2630/12/3/035012]; a projected normalized emittance below 0.4  μm for a charge of 200 pC and a bunch length of less than 10 ps (rms. A normalized projected emittance of 0.23  μm with 13 pC has been measured at 5 MeV using a Gaussian laser longitudinal intensity distribution on the photocathode. Good agreements with simulations have been obtained for different electron bunch charge and diode geometries. Emittance measurements at a bunch charge below 1 pC were performed for different laser spot sizes in agreement with intrinsic emittance theory [e.g. 0.54  μm/mm of laser spot size (rms for Cu at 274 nm]. Finally, a projected emittance of 1.25+/-0.2  μm was measured with 200 pC and 100  MV/m diode gradient.

  9. Joule-Thomson effect in a Pierce electron gun

    International Nuclear Information System (INIS)

    Batalin, V.A.

    1982-01-01

    A model which can be investigated both by means of the system of Vlasov equations and by means of ideal gas state equation is proposed for evaluation of emittance growth in the Pierce electron gun of electron beam with the limiting small distribution rate and intended for electron cooling facilities. The assumption has been made that transverse emittance growth is different from the zero. Thermodynamical approach to the problem of electron beam propagation permits to evaluate the increase of its emittance. It is shown that the increase of the electron beam emittance in the Pierce electron gun is similar to Joule-Thompson effect for gases. The effect increases with the decrease of the beam initial temperature. The increase of the emittance can become essential even in hte perfect (without aberration) Pierce optics at beam transverse temperature of the order of 0.1 eV

  10. Highly efficient electron gun with a single-atom electron source

    International Nuclear Information System (INIS)

    Ishikawa, Tsuyoshi; Urata, Tomohiro; Cho, Boklae; Rokuta, Eiji; Oshima, Chuhei; Terui, Yoshinori; Saito, Hidekazu; Yonezawa, Akira; Tsong, Tien T.

    2007-01-01

    The authors have demonstrated highly collimated electron-beam emission from a practical electron gun with a single-atom electron source; ∼80% of the total emission current entered the electron optics. This ratio was two or three orders of magnitude higher than those of the conventional electron sources such as a cold field emission gun and a Zr/O/W Schottky gun. At the pressure of less than 1x10 -9 Pa, the authors observed stable emission of 20 nA, which generates the specimen current of 5 pA required for scanning electron microscopes

  11. Applications of Electronstatic Lenses to Electron Gun and Energy Analyzers

    International Nuclear Information System (INIS)

    Sise, O.

    2004-01-01

    Focal properties and geometries are given for several types of electrostatic lens systems commonly needed in electron impact studies. One type is an electron gun which focuses electrons over a wide range of energy onto a fixed point, such as target, and the other type is an analyzer system which focuses scattered electrons of variable energy onto a fixed position, such as the entrance plane of an analyzer. There are many different types and geometries of these lenses for controlling and focusing of the electron beams. In this presentation we discussed the criteria used for the design of the electrostatic lenses associated with the electron gun and energy analyzers and determined the fundamental relationships between the operation and behaviour of multi-element electrostatic lenses, containing five, six and seven elements. The focusing of the electron beam was achieved by applying suitable voltages to the series of these lens elements, Design of the lens system for electron gun was based on our requirements that the beam at the target had a small spot size and zero beam angle, that is, afocal mode. For energy analyzer systems we considered the entrance of the hemispherical analyzer which determines the energy of the electron beam and discussed the focusing condition of this lens systems

  12. Numerical modelling of the CEBAF electron gun with EGUN

    International Nuclear Information System (INIS)

    Liger, P.; Krafft, G.A.

    1991-01-01

    The electron source used in the injector for the CEBAF accelerator is a Hermosa electron gun with a 2 mm diameter cathode and a control electrode. It produces a 100 keV electron beam to be focused on the first of two apertures which comprise an emittance filter. A normalized emittance of less than π mm mrad at 1.2 mA is set by the requirements of the final beam from the CEBAF linac, since downstream of the filter, a system of two choppers and a third aperture removes 5/6 of the current. In addition, for RF test purposes a higher current of about 5 mA is needed, possibly at higher emittance. This paper presents a way of calculating the characteristics of the CEBAF electron gun with the gun design code EGUN, and the accuracy of the results is discussed. The transverse shape of the beam delivered by the gun has been observed, and its current measured. A halo around the beam has been seen, and the calculations can reproduce this effect

  13. Developments in the electron gun simulation program, EGUN

    International Nuclear Information System (INIS)

    Herrmannsfeldt, W.B.

    1994-11-01

    This paper discusses the developments in the electron gun simulation programs that are based on EGUN with its derivatives and supporting programs. Much of the code development has been inspired by technology changes in computer hardware; the implications of this evolution on EGN2 are discussed. Some examples and a review of the capabilities of the EGUN family are described

  14. Developments in the electron gun simulation program, EGUN

    Science.gov (United States)

    Herrmannsfeldt, W. B.

    1995-07-01

    This paper discusses the developments in the electron gun simulation programs that are based on EGUN with its derivatives and supporting programs. Much of the code development has been inspired by technology changes in computer hardware; the implications of this evolution on EGN2 are discussed. Some examples and a review of the capabilities of the EGUN family are described.

  15. Cerenkov Radiator Driven by a Superconducting RF Electron Gun

    International Nuclear Information System (INIS)

    Poole, B.R.; Harris, J.R.

    2011-01-01

    The Naval Postgraduate School (NPS), Niowave, Inc., and Boeing have recently demonstrated operation of the first superconducting RF electron gun based on a quarter wave resonator structure. In preliminary tests, this gun has produced 10 ps long bunches with charge in excess of 78 pC, and with beam energy up to 396 keV. Initial testing occurred at Niowave's Lansing, MI facility, but the gun and diagnostic beam line are planned for installation in California in the near future. The design of the diagnostic beam line is conducive to the addition of a Cerenkov radiator without interfering with other beam line operations. Design and simulations of a Cerenkov radiator, consisting of a dielectric lined waveguide will be presented. The dispersion relation for the structure is determined and the beam interaction is studied using numerical simulations. The characteristics of the microwave radiation produced in both the short and long bunch regimes will be presented.

  16. Results from operation of metal melting electron gun

    International Nuclear Information System (INIS)

    Balloni, A.J.; Paes, A.C.J.; Miliano, A.C.

    1988-09-01

    The first results obtained during the operation of metal melting electron gun, of power 30Kw and current 1,2A, developed at IEAv, are presented. Details on operation of beam transport system (composed by magnetic lens and prism), from generation to fusion chamber and cathode construction. Into the fusion chamber the presssure can reach 10 -4 Pa, seeing that the gun test consisted in fusion for purification of approximatelly 1Kg titanium bar. The input average power was 12Kw, and the fusion remainded during 16 minutes. The calculated thermal efficiency was of the order of 10% consistent with the results found out in literature, for this type of gun. (M.C.K.) [pt

  17. A line beam electron gun for rapid thermal processing

    Science.gov (United States)

    Pauli, M.; Müller, J.; Hartkopf, K.; Barth, T.

    1992-04-01

    A line beam electron gun based on the Pierce gun type was developed. The line cathode was realized by a directly heated tungsten rod. The temperature distribution along the tungsten rod was simulated numerically. The simulation shows a flat temperature across 2/3 of the cathode length and it agrees with appropriate measurable parameters. The beam profiles of the electron gun perpendicular to the line direction were examined as a function of electrical and geometrical parameters: The space-charge distribution in front of the cathode was found to be responsible for the shape of the beam profile. The shape of the beam profile is weakly influenced by the acceleration to the anode. The heating current induced voltage drop along the cathode was found to be responsible for the nonuniform emission in line direction. A model for the emission behavior of the line beam electron gun was developed. The model is based on the results of the measurements and on a numerical simulation of the potential distribution in the area between Pierce reflectors and anode. The emission model shows a solution to homogenize the emission by a suitable variation of geometrical parameters in line direction. A linear variation was realized in experiment which enables a uniform emission across 2/3 of the cathode length. The beam profile is adjustable by a bias voltage between the cathode and the Pierce reflectors.

  18. Performance of a 150-MW S-band klystron

    International Nuclear Information System (INIS)

    Sprehn, D.; Phillips, R.M.; Caryotakis, G.

    1994-09-01

    As part of an international collaboration, the Stanford Linear Accelerator Center (SLAC) klystron group has designed, fabricated, and tested a 60-Hz, 3-μs, 150-MW S-band klystron built for Deutsches Elektronen Synchrotron (DESY). A test diode with a 535-kV, 700-A electron beam was constructed to verify the gun operation. The first klystron was built and successfully met design specifications. The 375-MW electron beam represents a new record for SLAC accelerator klystrons in terms of voltage, current, energy, and ruggedness of design. The rf output power is a 150% increase over the S-band tubes currently used in the two-mile-long linear accelerator at SLAC. This paper discusses design issues and experimental results of the diode and klystron

  19. Operating experience with the polarized electron gun at SLAC

    International Nuclear Information System (INIS)

    Alguard, M.J.; Baum, G.; Clendenin, J.E.; Hughes, V.W.; Lubell, M.S.; Miller, R.H.; Raith, W.; Schuler, K.P.; Sodja, J.

    1977-03-01

    During the two years of operation of the SLAC Polarized Electron Gun (PEGGY), the electron intensity delivered to the target has increased from 7 x 10 7 e - /pulse to 1 x 10 9 e - /pulse. The polarization is 0.85 with no measurable degradation caused by acceleration through the linear accelerator. The predominant cause of downtime is replenishment of lithium, which now averages 43 hours. The lifetime of a lithium load is about 175 hours

  20. Thermomechanical Impact of Polyurethane Potting on Gun Launched Electronics

    Directory of Open Access Journals (Sweden)

    A. S. Haynes

    2013-01-01

    Full Text Available Electronics packages in precision guided munitions are used in guidance and control units, mission computers, and fuze-safe-and-arm devices. They are subjected to high g-loads during gun launch, pyrotechnic shocks during flight, and high g-loads upon impact with hard targets. To enhance survivability, many electronics packages are potted after assembly. The purpose of the potting is to provide additional structural support and shock damping. Researchers at the US Army recently completed a series of dynamic mechanical tests on a urethane-based potting material to assess its behavior in an electronics assembly during gun launch and under varying thermal launch conditions. This paper will discuss the thermomechanical properties of the potting material as well as simulation efforts to determine the suitability of this potting compound for gun launched electronics. Simulation results will compare stresses and displacements for a simplified electronics package with and without full potting. An evaluation of the advantages and consequences of potting electronics in munitions systems will also be discussed.

  1. Electron gun design study for the IUCF beam cooling system

    International Nuclear Information System (INIS)

    Friesel, D.L.; Ellison, T.; Jones, W.P.

    1985-01-01

    The design of a low temperature electron beam cooling system for the Indiana University electron-cooled storage ring is in progress. The storage ring, which will accept the light ion beams from the existing k=200, multi-stage cyclotron facility, requires an electron beam variable in energy from about 7 to 275 keV. The electron beam system consists of a high perveance electron gun with Pierce geometry and a flat cathode. The gun and a 28 element accelerating column are immersed in a uniform longitudinal magnetic guide field. A computer modeling study of the system was conducted to determine electron beam density and transverse temperature variations as a function of anode region and accelerator column design parameters. Transverse electron beam temperatures (E /SUB t/ = mc 2 β 2 γ(/theta/ /SUB H/ +/theta/ /SUB v/ )) of less than a few tenths of an electron volt at a maximum current density of 0.4 A/cm 2 are desired over the full energy range. This was achieved in the calculations without the use of resonant focusing for a 2 Amp, 275 keV electron beam. Some systematics of the electron beam temperature variations with system design parameters are presented. A short discussion of the mechanical design of the proposed electron beam system is also given

  2. Numerical design of electron guns and space charge limited transport systems

    International Nuclear Information System (INIS)

    Herrmannsfeldt, W.B.

    1980-10-01

    This paper describes the capabilities and limitations of computer programs used to design electron guns and similarly space-charge limited transport systems. Examples of computer generated plots from several different types of gun problems are included

  3. A ferroelectric electron gun in a free-electron maser experiment

    CERN Document Server

    Einat, M; Rosenman, G

    2002-01-01

    An electron-gun based on a ferroelectric cathode is studied in a free-electron maser (FEM) experiment. In this gun, the electrons are separated from the cathode surface plasma, and are accelerated in two stages. The electron energy-spread is reduced sufficiently for an FEM operation in the microwave regime. A 14 keV, 1-2 A e-beam is obtained in a 0.1-2.1 mu s pulse width. The pulse repetition frequency attains 3.1 MHz in approx 50% duty-cycle. This gun is implemented in an FEM oscillator experiment operating around 3 GHz. The paper presents experimental results and discusses the applicability of ferroelectric guns in free-electron laser devices.

  4. A ferroelectric electron gun in a free-electron maser experiment

    International Nuclear Information System (INIS)

    Einat, M.; Jerby, E.; Rosenman, G.

    2002-01-01

    An electron-gun based on a ferroelectric cathode is studied in a free-electron maser (FEM) experiment. In this gun, the electrons are separated from the cathode surface plasma, and are accelerated in two stages. The electron energy-spread is reduced sufficiently for an FEM operation in the microwave regime. A 14 keV, 1-2 A e-beam is obtained in a 0.1-2.1 μs pulse width. The pulse repetition frequency attains 3.1 MHz in ∼50% duty-cycle. This gun is implemented in an FEM oscillator experiment operating around 3 GHz. The paper presents experimental results and discusses the applicability of ferroelectric guns in free-electron laser devices

  5. Formation of a high quality electron beam using photo cathode RF electron gun

    International Nuclear Information System (INIS)

    Washio, Masakazu

    2000-01-01

    Formation of a high quality electron beam using photo cathode RF electron gun is expected for formation of a next generation high brilliant X-ray beam and a source for electron and positron collider. And, on a field of material science, as is possible to carry out an experiment under ultra short pulse and extremely high precision in time, it collects large expectation. Recently, formation of high quality beam possible to develop for multi directions and to use by everyone in future has been able to realize. Here were explained on electron beam source, principle and component on RF electron gun, working features on RF gun, features and simulation of RF gun under operation, and some views in near future. (G.K.)

  6. Electron gun for formation of two high-current beams

    International Nuclear Information System (INIS)

    Borisov, A.R.; Zherlitsyn, A.G.; Mel'nikov, G.V.; Shtejn, Yu.G.

    1982-01-01

    The design of the ''Tonus'' accelerator electron gun for formation of two high-current beams aiming at the production of the maximum beam power and density is described. The results of investigation of two modes of beam formation are presented. In the first variant the beams were produced by means of two plane diodes with 40 mm diameter cathodes made of stainless steel and anodes made of 50 μm thick titanium foil. In the second variant the beams were formed by means of two coaxial diodes with magnetic insulation. In one diode the cathode diameter equals to 74 mm, the anode diameter - 92 mm, in the other diode 16 and 44 mm respectively. Current redistribution in the diodes and its effect on accelerating voltage are investigated. It is shown that the gun permits formation of synchronized two high-current beams, iaving equal electron energied. Wide range current control of both beams is possible

  7. Note: Simulation and test of a strip source electron gun.

    Science.gov (United States)

    Iqbal, Munawar; Islam, G U; Misbah, I; Iqbal, O; Zhou, Z

    2014-06-01

    We present simulation and test of an indirectly heated strip source electron beam gun assembly using Stanford Linear Accelerator Center (SLAC) electron beam trajectory program. The beam is now sharply focused with 3.04 mm diameter in the post anode region at 15.9 mm. The measured emission current and emission density were 1.12 A and 1.15 A/cm(2), respectively, that corresponds to power density of 11.5 kW/cm(2), at 10 kV acceleration potential. The simulated results were compared with then and now experiments and found in agreement. The gun is without any biasing, electrostatic and magnetic fields; hence simple and inexpensive. Moreover, it is now more powerful and is useful for accelerators technology due to high emission and low emittance parameters.

  8. Emittance measurement for high-brightness electron guns

    International Nuclear Information System (INIS)

    Kobayashi, H.; Kurihara, T.; Sato, I.; Asami, A.; Yamazaki, Y.; Otani, S.; Ishizawa, Y.

    1992-01-01

    An emittance measurement system based on a high-precision pepper-pot technique has been developed for electron guns with low emittance of around πmm-mrad. Electron guns with a 1 mmφ cathode, the material of which is impregnated tungsten or single-crystal lanthanum hexaboride (La 1-x Ce x )B 6 , have been developed. The performance has been evaluated by putting stress on cathode roughness, which gives rise to an angular divergence, according to the precise emittance measurement system. A new type of cathode holder, which is a modified version of the so called Vogel type, was developed and the beam uniformity has been improved. (Author) 5 figs., tab., 9 refs

  9. Developments in the electron gun simulation program, EGUN

    International Nuclear Information System (INIS)

    Herrmannsfeldt, W.B.

    1995-01-01

    This paper discusses the developments in the electron gun simulation programs that are based on EGUN with its derivatives and supporting programs. Much of the code development has been inspired by technology changes in computer hardware; the implications of this evolution on EGN2 are discussed. Some examples and a review of the capabilities of the EGUN family are described. copyright 1995 American Institute of Physics

  10. Development of control system for the electron gun modulator

    International Nuclear Information System (INIS)

    Hasegawa, T.; Nagasawa, S.; Kobayashi, T.; Hanaki, H.

    2004-01-01

    We have been developing a compact and inexpensive electron gun modulator for the SPring-8 Linac. The modulator was redesigned and manufactured to achieve good maintainability and high controllability. A control system of the modulator and a high voltage station is composed mainly of PLCs as a controller and touch panels for human interface. This simplified construction will result in enhancement of its reliability. The rich graphical user interface on the touch panels greatly extends the function of the control system. (author)

  11. Design, development and characterization of tetrode type electron gun system for generation of low energy electrons

    International Nuclear Information System (INIS)

    Deore, A.V.; Bhoraskar, V.N.; Dhole, S.D.

    2011-01-01

    A tetrode type electron gun system for the generation of low energy electrons was designed, developed and characterized. An electron gun having four electrodes namely cathode, focusing electrode, control electrode and anode has been designed for the irradiation experiments. This electron gun is capable to provide electrons of energy over the range of 1 keV to 20 keV, with current maximum upto 100 μA. The electron gun and a faraday cup are mounted in the evacuated cylindrical chamber. The samples are fixed on the faraday cup and irradiated with low energy electrons at a pressure around 10 -6 mbar. In this electron gun system, at any electron energy over the entire range, the electron beam diameter can be varied from 5 to 120 mm on the Faraday cup mounted at a distance of 200 mm from the anode in the chamber. Also, the circular shape of the beam spot was maintained, even though the beam current and beam diameter are varied. The uniformity of the electron beam over the entire beam area was measured with a multi electrode assembly and found to be well within 15%. This system is being used for the synthesis and diffusion of metal and semiconductor nanoparticles in polymeric materials. (author)

  12. Synchronizaiton Between Laser and Electron Beam at Photocathode RF Gun

    CERN Document Server

    Sakumi, Akira; Fukasawa, Atsushi; Kumagai, Noritaka; Muroya, Yusa; Tomizawa, Hiromitsu; Ueda, T; Uesaka, Mitsuru; Urakawa, Junji; Yoshii, K

    2005-01-01

    The chemical reactions of hot, room temperature and critical water in a time-range of picosecond and sub-picosecond have been carried out by the 18 MeV S-band linac and a Mg photocathode RF gun with the irradiation of third harmonic Ti: Sapphire laser, at Nuclear Engineering Research Laboratory (NERL), the University of Tokyo. Although this short bunch and 100 fs laser light are enough to perform the experiment of radiation chemistry in the time-range of sub-picosecond, the total time-resolution become worse by the instability of synchronization between laser and radio frequency of linac. We found that the fluctuation of room temperature causes the instability, particularly the cycle of turning on/off of the air-conditioner. It is shown that 0.3 °C (peak-to-peak) fluctuation of the laser-room temperature have approximately corresponded to the instability of 6 ps. We are trying to decrease the fluctuation of the room temperature, together with the local temperature stability of the Ti: Sapphire crysta...

  13. Performance review of thermionic electron gun developed for RF linear accelerators at RRCAT

    International Nuclear Information System (INIS)

    Wanmode, Yashwant; Mulchandani, J.; Reddy, T.S.; Bhisikar, A.; Singh, H.G.; Shrivastava, Purushottam

    2015-01-01

    RRCAT is engaged in development of RF electron linear accelerator for irradiation of industrial and agricultural products. Thermionic electron gun is primary source for this accelerator as beam current in the RF accelerator is modest and thermionic emission is most prevalent option for electron gun development. An electron gun has to meet high cathode emission capability, low filament power, good accessibility for cathode replacement and should provide short time for maintenance. Electron linear accelerator up to beam energy of 10 MeV require electron source of 45-50 keV beam energy and emission current of 1 A. Electron optics of gun and electron beam profile simulations were carried out using CST's particle tracking code and EGUN code. Triode type electron gun of cathode voltage 50 kV pulsed has been designed, developed and integrated with 10 MeV electron linear accelerators at RRCAT. Beam current of more than 600 mA has been measured with faraday cup in the test stand developed for characterizing the electron gun. Two accelerators one is imported and another one developed indigenously has been energized using this electron gun. Beam energy of 5-10 MeV has been achieved with beam current of 250-400 mA by integrating this electron gun with the linear accelerator. This paper reviews the performance of indigenously developed electron gun for both linear accelerators. (author)

  14. Non-channel magnetron gun as the electron source for resonance linear accelerator

    International Nuclear Information System (INIS)

    Ivanov, G.M.; Makhnenko, L.A.; Cherenshchikov, S.A.

    1999-01-01

    Studies on the magnetron gun with a cold cathode being part of linear accelerator on the travelling wave are described. Two modes of the gun operation differing by presence of UHF field of the pre-buncher near the gun are observed. In the mode without UHF field the short (about 2 ns) pulses of accelerated electrons with amplitude up to 0.5 A at the gun current up to 20 A were obtained. The presence of UHF field near the gun makes it possible to obtain the beam of higher duration (up to 1.0 μs), but with current up to 20 mA at the accelerator outlet and up to 1 A at the gun outlet. The mechanism of the gun operation is concerned with the secondary-electron current increase and setting self-sustaining secondary emission. Gun characteristics under study are acceptable for the purposes of injection into accelerator [ru

  15. The design of electron and ion guns, beams, and collectors

    Energy Technology Data Exchange (ETDEWEB)

    Becker, Reinard [Institut fuer Angewandte Physik der Universitaet Frankfurt/M, Fach 180, D-60054 (Germany); Herrmannsfeldt, William B [Stanford Linear Accclerator Center, Stanford University, CA (United States)

    2004-01-01

    The well known 'SLAC Electron Trajectory Program' (EGUN) has been ported to PCs and has been developed into a family of programs for the design and the optimization of particle optics devices including electron and ion guns, beam transport sections and collectors. We will discuss the application of these tools for the design and the optimization of the essential parts of EBIS/T devices. The discussion will include conditions in which restrictions in the reliability of simulations may occur due to the mathematical modeling and how to overcome them.

  16. The design of electron and ion guns, beams, and collectors

    Science.gov (United States)

    Becker, Reinard; Herrmannsfeldt, William B.

    2004-01-01

    The well known `SLAC Electron Trajectory Program' (EGUN) has been ported to PCs and has been developed into a family of programs for the design and the optimization of particle optics devices including electron and ion guns, beam transport sections and collectors. We will discuss the application of these tools for the design and the optimization of the essential parts of EBIS/T devices. The discussion will include conditions in which restrictions in the reliability of simulations may occur due to the mathematical modeling and how to overcome them.

  17. Characteristics of electron gun used in the accelerator for customs inspection systems

    International Nuclear Information System (INIS)

    Huang Weiling; Li Quanfeng; Zhang Yunkai

    2001-01-01

    The author introduces the characteristics of the electron gun used in the 9 MeV traveling wave electron linear accelerator for fixed customs container inspection system. With the scan date cathode, the electron gun meets the accelerator characteristics with the whole system not needing high-temperature roasting to degas. The electron gun can work normally at a vacuum of about 10 -5 Pa and can be reinstalled after exposure to air. In the accelerator, the electron gun emits a beam which strikes the target to produce an X-ray beam with a dosage rate of over 30 Gy/(min·m) and a beam focus spot of less than φ 2 mm. The EGUN code is used to simulate the structure and properties of the electron gun. The reference size debugging parameters for replacing the electron gun are given for assembly requirements

  18. An angular selective electron gun for the KATRIN experiment

    Energy Technology Data Exchange (ETDEWEB)

    Zacher, Michael; Ortjohann, Hans-Werner; Steinbrink, Nicholas; Josten, Lorenz; Hannen, Volker; Weinheimer, Christian; Winzen, Daniel [Westfaelische Wilhelms-Universitaet, Muenster (Germany); Collaboration: KATRIN-Collaboration

    2013-07-01

    The KArlsruhe TRItium Neutrino experiment aims for a measurement of the electron anti-neutrino mass with a sensitivity of 200 meV/c{sup 2} (95% C.L.) by analysing the endpoint region of the tritium β-decay. The main spectrometer (MAC-E filter type, 23m length) is one of the central parts of the experiment, featuring an energy resolution of Δ E<1 eV. For commissioning of the spectrometer a well defined electron source is needed that allows to determine the transmission characteristics and compare the electromagnetic properties to simulations. For this purpose an angular selective electron gun was developed. A pulsed UV-Laser produces electrons via the photo-electric effect, which are then accelerated electrostatically in a magnetic field. It features a small energy spread, a sharp selectable emission angle and covers the whole magnetic flux tube of KATRIN. By that, the characteristics of the spectrometer can be investigated with high precision. The time structure of the electron pulses allows time of flight measurements, offering enhanced sensitivity. The talk gives an overview about the e-gun design and its properties.

  19. The structural design of an electron gun for an E-beam irradiator

    International Nuclear Information System (INIS)

    Yu Xiaojuan; Wu Xunlei; Jiang Zhenbo; Meng Mingfeng

    2011-01-01

    In this paper, an electron gun for a linac E-beam irradiator is developed with a replaceable cathode and filament. The structure of cathode and filament and the concentric technique, with molds and clamps, are described in detail. The electron gun was assembled with care to reduce the error, and ensure the concentricity of electron gun. The test results indicated a 99.99% pass ratio of the electron beams at 60-65 kV. The electron gun design meets the technical requirement of clients. (authors)

  20. Experimental design of high energy electron gun by means of scaling rules

    International Nuclear Information System (INIS)

    Wojcicki, S.

    1996-01-01

    The possibility of the design of a new family of electron guns by means of scaling theory of electron-optical devices (EOD) is presented. According to the theory, EOD with a relatively big space charge, as in high energy Pierce type electron guns used in technological equipment, generally cannot be scaled, because of their nonlinear space charge nature. Therefore, the scaling rules are applied here only to the anode zone of the gun, where the electron beam perveance is small, and the cathode lens of gun with considerable space charge remains unchanged. The procedure for scaling a 25 kV and 150 mA gun with cylindrical electron beam into a high voltage 75 kV and 150 mA electron system is given. An experimental investigation proved the high technological quality of a high voltage gun constructed according to the above conception. (author)

  1. Investigation and optimisation of a plasma cathode electron beam gun for material processing applications

    OpenAIRE

    Del Pozo Rodriguez, Sofia

    2016-01-01

    This thesis was submitted for the degree of Doctor of Philosophy and awarded by Brunel University London. This thesis describes design, development and testing work on a plasma cathode electron beam gun as well as plasma diagnosis experiments and Electron Beam (EB) current measurements carried out with the aim of maximising the power of the EB extracted and optimising the electron beam gun system for material processing applications. The elements which influence EB gun design are described...

  2. Development of an electron gun for high power CW electron linac

    International Nuclear Information System (INIS)

    Yamazaki, Yoshio; Nomura, Masahiro

    1994-01-01

    An electron gun launching high average current beam has been designed for the high power CW electron linac at PNC. A peak electron beam current of 400mA with beam energy 200keV is required from the buncher design. However its average current is very high(duty factor 20%), a mesh grid is not able to be used for current control because of heating up or melting of grid. Furthermore, the beam current have to be variable up to 400mA to match with downstream modules, especially the accelerating guides including recirculating system. We employed the electron gun with two aperture grids to control beam current. The dimension of the electrodes, electron trajectory, the size of beam radius, and gun emittance was simulated by EGUN. (author)

  3. Electron ray tracing programs for gun design and beam transport

    International Nuclear Information System (INIS)

    Herrmannsfeldt, W.B.

    1988-05-01

    Computer simulation of electron and ion sources is made by using a class of computer codes known as gun design programs. In this paper, we shall first list most of the necessary and some optional capabilities of such programs. Then we will briefly note specific codes and/or authors of codes with attention to specialized applications if any. There may be many more such programs in use than are treated here; we are only trying to cover a range of examples, not perform a comprehensive survey

  4. A 20 keV electron gun system for the electron irradiation experiments

    International Nuclear Information System (INIS)

    Mahapatra, S.K.; Dhole, S.D.; Bhoraskar, V.N.

    2005-01-01

    An electron gun consisting of cathode, focusing electrode, control electrode and anode has been designed and fabricated for the electron irradiation experiments. This electron gun can provide electrons of any energy over the range 1-20 keV, with current upto 50 μA. This electron gun and a Faraday cup are mounted in the cylindrical chamber. The samples are fixed on the Faraday cup and irradiated with electrons at a pressure ∼10 -7 mbar. The special features of this electron gun system are that, at any electron energy above 1 keV, the electron beam diameter can be varied from 5 to 120 mm on the Faraday cup mounted at a distance of 200 mm from the anode in the chamber. The variation in the electron current over the beam spot of 120 mm diameter is less than 15% and the beam current stability is better than 5%. This system is being used for studying the irradiation effects of 1-20 keV energy electrons on the space quality materials in which the irradiation time may vary from a few tens of seconds to hours

  5. A 20 keV electron gun system for the electron irradiation experiments

    Energy Technology Data Exchange (ETDEWEB)

    Mahapatra, S.K. [Department of Physics, University of Pune, Pune 411007 (India); Dhole, S.D. [Department of Physics, University of Pune, Pune 411007 (India); Bhoraskar, V.N. [Department of Physics, University of Pune, Pune 411007 (India)]. E-mail: vnb@physics.unipune.ernet.in

    2005-01-01

    An electron gun consisting of cathode, focusing electrode, control electrode and anode has been designed and fabricated for the electron irradiation experiments. This electron gun can provide electrons of any energy over the range 1-20 keV, with current upto 50 {mu}A. This electron gun and a Faraday cup are mounted in the cylindrical chamber. The samples are fixed on the Faraday cup and irradiated with electrons at a pressure {approx}10{sup -7} mbar. The special features of this electron gun system are that, at any electron energy above 1 keV, the electron beam diameter can be varied from 5 to 120 mm on the Faraday cup mounted at a distance of 200 mm from the anode in the chamber. The variation in the electron current over the beam spot of 120 mm diameter is less than 15% and the beam current stability is better than 5%. This system is being used for studying the irradiation effects of 1-20 keV energy electrons on the space quality materials in which the irradiation time may vary from a few tens of seconds to hours.

  6. Annular-cathode electron gun for in-line injection in a racetrack microtron

    International Nuclear Information System (INIS)

    Manca, J.J.; Edmonds, D.S. Jr.; Froelich, H.R.

    1976-01-01

    A compact annular-cathode electron gun which allows direct, efficient injection into the accelerating structure of a racetrack microtron was designed, built, and tested. The gun operates under pulsed conditions with applied high voltages of 40 kV or more and delivers an output current in excess of 1 A. Design and construction details are presented for both a basic gun and a gun with built-in output current monitor. Gun performance in a test chamber and in the multicavity racetrack microtron at the University of Western Ontario is described

  7. Control-grid electron gun as a source of modulated electron beam for a collective accelerator

    International Nuclear Information System (INIS)

    Bakumenko, A.A.; Belikov, V.V.; Zvyagintsev, A.V.; Lyul'chenko, V.I.; Lymar', A.G.; Martynenko, P.A.; Suryadnyj, A.V.

    1989-01-01

    Structure is described and experimental results of investigations into an electron gun with transverse beam compression and control grid are presented. The pulse trailing edge is formed by a sectioned discharger. A modulated electron beam with the following parameters: 110 keV beam energy, 70 A current amplitude, 3-8 MHz modulation frequency, 100% modulation depth, ≅8-6 mm minimal beam diameter, ≅ 10μs pulse duration, 3% pulse top non-uniformity, more than 200 compression degree is obtained when introducing the positive feedback in auto-generator regime to the gun supply circuit. Further it is supposed to use the developed electron gun for heavy ion acceleration by a field of space charge of a modulated electron beam in a corrugated liner. It should be underlined that power supply of such an accelerator does not require powerful outside HF generator. 5 refs.; 1 fig

  8. Simulation and analysis of secondary emission microwave electron gun

    International Nuclear Information System (INIS)

    He Wencan; Pei Yuanji; Jin Kai; Wu Congfeng

    2001-01-01

    The development of high-current, short-duration pulses of electrons has been a challenging problem for many year. Micro-pulse-gun (MPG) is a novel concept that employs the resonant amplification of an electron current by secondary electron emission in a RE cavity. Using the computation code URMEL-T, several kinds of RF cavities under the frequency of 2856 MHz were calculated and optimized, the magnetic and electric field distribution in them were got. Through particle-in-cell (PIC) simulation, the self-bunching process in a MPG was proved, the relationship between the cavity length and selected phase and the relationship between the peak electric field and selected phase were got. With cathode material of high secondary emission coefficient, the MPG can produce high current densities (1132-5303 A/cm 2 ) and short pulses (3.15-10 ps)

  9. Low-energy plasma-cathode electron gun with a perforated emission electrode

    Science.gov (United States)

    Burdovitsin, Victor; Kazakov, Andrey; Medovnik, Alexander; Oks, Efim; Tyunkov, Andrey

    2017-11-01

    We describe research of influence of the geometric parameters of perforated electrode on emission parameters of a plasma cathode electron gun generating continuous electron beams at gas pressure 5-6 Pa. It is shown, that the emission current increases with increasing the hole diameters and decreasing the thickness of the perforated emission electrode. Plasma-cathode gun with perforated electron can provide electron extraction with an efficiency of up to 72 %. It is shown, that the current-voltage characteristic of the electron gun with a perforated emission electrode differs from that of similar guns with fine mesh grid electrode. The plasma-cathode electron gun with perforated emission electrode is used for electron beam welding and sintering.

  10. Femtosecond electron bunches from an RF-gun

    International Nuclear Information System (INIS)

    Rimjaem, Sakhorn; Farias, Ruy; Thongbai, Chitrlada; Vilaithong, Thiraphat; Wiedemann, Helmut

    2004-01-01

    Sub-picosecond electron pulses become a tool of increasing importance to study dynamics at an atomic level. Such electron pulses can be used directly or be converted into intense coherent far infrared radiation or equally short X-ray pulses. In principle, sub-picosecond electron pulses can be obtained in large, high-energy electron linear accelerator systems by repeatedly applying an energy slew and magnetic compression. Another process is the production of short electron pulses at low energies from an RF-gun with a thermionic cathode together with a bunch compressing α-magnet. In this paper, we present a systematic analysis of capabilities and limits of sub-picosecond electron pulses from such a source. We discuss particular parameter choices as well as the impact of geometric and electric specifications on the 6-dimensional phase space electron distribution. Numerical beam simulations with the computer code PARMELA are performed including effects and limitations due to space charge forces. While the production of femtosecond electron bunches is of primary concern, we also consider the preservation of such short bunches along a beam transport line

  11. Numerical simulations of the thermionic electron gun for electron-beam welding and micromachining

    Czech Academy of Sciences Publication Activity Database

    Jánský, Pavel; Zlámal, J.; Lencová, Bohumila; Zobač, Martin; Vlček, Ivan; Radlička, Tomáš

    2009-01-01

    Roč. 84, č. 2 (2009), s. 357-362 ISSN 0042-207X R&D Projects: GA AV ČR IAA100650805 Institutional research plan: CEZ:AV0Z20650511 Keywords : Numerical simulation * Thermionic emission * Electron gun Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 0.975, year: 2009

  12. Thermal characterization of indirectly heated axi-symmetric solid cathode electron beam gun for melting application

    International Nuclear Information System (INIS)

    Prakash, B.; Gupta, S.; Malik, P.; Mishra, K.K.; Jha, M.N.; Kandaswamy, E.; Martin, M.

    2015-01-01

    Electron beam melting gun with indirectly heated axi-symmetric solid cathode was designed, fabricated and characterized experimentally. The thermal simulation and optical analysis of the electron gun was carried out to estimate the power required to achieve the emission temperature of the solid cathode, to obtain the temperature distribution in the assembly and the beam transportation. On the basis of the thermal simulation and electron optics, the electron gun design was finalised. The electron gun assembly was fabricated and installed in the vacuum chamber for carrying out the experiment to find the actual temperature distribution. Thermocouple and two colour pyrometer were used to measure the temperature at various locations in the electron gun. The attenuation effect of the viewing port glass of the vacuum chamber was compensated in the final reading of the temperature measured by the pyrometer. The temperature of solid cathode obtained by the experiment was found to be 2800K which is the emission temperature of solid cathode. (author)

  13. Development of the high-power THz spectroscopy and imaging systems on the basis of an S-band compact electron LINAC

    International Nuclear Information System (INIS)

    Kuroda, R.; Taira, Y.; Tanaka, M.; Toyokawa, H.; Yamada, K.; Kumaki, M.; Tachibana, M.; Sakaue, K.; Washio, M.

    2014-01-01

    The high-power terahertz time-domain spectroscopy (THz-TDS) and imaging systems have been developed on the basis of an S-band compact electron linac at AIST. Such high-power THz source is strongly expected for inspection of dangerous materials in the homeland security field. The high-power THz radiations are generated in two methods with the high-brightness ultra-short electron bunch. One is THz coherent synchrotron radiation (THz-CSR) for THz imaging applications. The other is THz coherent transition radiation (THz-CTR) for the THz spectroscopy. The THz-CTR time-domain spectroscopy (TDS) has been constructed with the EO sampling method and demonstrated in freq. range between 0.1-2 THz. The absorption measurements of drug samples have been successfully performed in atmosphere. In this symposium, we will describe details of the THz-CTR-TDS and imaging experiments and a future plan of the THz applications. (author)

  14. Design, construction and tuning of S-band coupler for electron linear accelerator of institute for research in fundamental sciences (IPM E-linac)

    International Nuclear Information System (INIS)

    Ghasemi, F.; Abbasi Davani, F.; Lamehi Rachti, M.; Shaker, H.; Ahmadiannamin, S.

    2015-01-01

    Design and construction of an electron linear accelerator by Institute for Research in Fundamental Science (IPM) is considered as Iran’s first attempt to construct such an accelerator. In order to design a linear accelerating tube, after defining the accelerating tube and buncher geometries, RF input and output couplers must be designed. In this article, firstly, a brief report on the specifications of an S-band electron linear accelerator which is in progress in the school of particles and accelerators is presented and then, the design process and construction reports of the couplers required for this accelerator are described. Through performing necessary calculations and tuning the coupling factor and resonant frequency, couplers with desired specification have been fabricated by shrinking method. The final obtained coupling factor and resonant frequency have been respectively 1.05 and 2997 MHz for the first coupler, and 0.98 and 2996.9 MHz for the second one that are close to calculation results

  15. Design and performance of a 30 KV electron gun with ten independent cathodes & a magnetic lens.

    Energy Technology Data Exchange (ETDEWEB)

    Rudys, Joseph Matthew; Reed, Kim Warren

    2006-08-01

    Measurements on a 30 kV electron gun with ten independent cathodes, operating in a 6.5 Tesla (T) magnetic field are presented. An earlier paper covered the design of this electron gun [1]. Experimental results are compared to model predictions. Beam current is compared to theoretical space charge limited flow.

  16. Advanced laser technologies for high-brightness photocathode electron gun

    International Nuclear Information System (INIS)

    Tomizawa, Hiromitsu

    2012-01-01

    A laser-excited photocathode RF gun is one of the most reliable high-brightness electron beam sources for XFELs. Several 3D laser shaping methods have been developed as ideal photocathode illumination sources at SPring-8 since 2001. To suppress the emittance growth caused by nonlinear space-charge forces, the 3D cylindrical UV-pulse was optimized spatially as a flattop and temporally as squarely stacked chirped pulses. This shaping system is a serial combination of a deformable mirror that adaptively shapes the spatial profile with a genetic algorithm and a UV-pulse stacker that consists of four birefringent α-BBO crystal rods for temporal shaping. Using this 3D-shaped pulse, a normalized emittance of 1.4 πmm mrad was obtained in 2006. Utilizing laser's Z-polarization, Schottky-effect-gated photocathode gun was proposed in 2006. The cathode work functions are reduced by a laser-induced Schottky effect. As a result of focusing a radially polarized laser pulse with a hollow lens in vacuum, the Z-field (Z-polarization) is generated at the cathode. (author)

  17. Advanced Laser Technologies for High-brightness Photocathode Electron Gun

    Science.gov (United States)

    Tomizawa, Hiromitsu

    A laser-excited photocathode RF gun is one of the most reliable high-brightness electron beam sources for XFELs. Several 3D laser shaping methods have been developed as ideal photocathode illumination sources at SPring-8 since 2001. To suppress the emittance growth caused by nonlinear space-charge forces, the 3D cylindrical UV-pulse was optimized spatially as a flattop and temporally as squarely stacked chirped pulses. This shaping system is a serial combination of a deformable mirror that adaptively shapes the spatial profile with a genetic algorithm and a UV-pulse stacker that consists of four birefringent α-BBO crystal rods for temporal shaping. Using this 3D-shaped pulse, a normalized emittance of 1.4 π mm mrad was obtained in 2006. Utilizing laser's Z-polarization, Schottky-effect-gated photocathode gun was proposed in 2006. The cathode work functions are reduced by a laser-induced Schottky effect. As a result of focusing a radially polarized laser pulse with a hollow lens in vacuum, the Z-field (Z-polarization) is generated at the cathode.

  18. Thermionic gun control system for the CEBAF [Continuous Electron Beam Accelerator Facility] injector

    International Nuclear Information System (INIS)

    Pico, R.; Diamond, B.; Fugitt, J.; Bork, R.

    1989-01-01

    The injector for the CEBAF accelerator must produce a high-quality electron beam to meet the overall accelerator specifications. A Hermosa electron gun with a 2 mm-diameter cathode and a control aperture has been chosen as the electron source. This must be controlled over a wide range of operating conditions to meet the beam specifications and to provide flexibility for accelerator commissioning. The gun is controlled using Computer Automated Measurement and Control (CAMAC IEEE-583) technology. The system employs the CAMAC-based control architecture developed at CEBAF. The control system has been tested, and early operating data on the electron gun and the injector beam transport system has been obtained. This system also allows gun parameters to be stored at the operator location, without paralyzing operation. This paper describes the use of this computer system in the control of the CEBAF electron gun. 2 refs., 6 figs., 1 tab

  19. CEBAF 200 kV Inverted Electron Gun

    International Nuclear Information System (INIS)

    Grames, J.M.; Adderley, P.A.; Clark, J.; Hansknecht, J.; Poelker, M.; Stutzman, M.L.; Suleiman, R.; Surles-Law, K.E.L.

    2011-01-01

    Two DC high voltage GaAs photoguns have been built at Jefferson Lab based on a compact inverted insulator design. One photogun provides the polarized electron beam at CEBAF and operates at 130 kV bias voltage. The other gun is used for high average current lifetime studies at a dedicated test facility and has been operated at bias voltage up to 225 kV. The advantages of higher DC voltage for CEBAF include reduced space-charge emittance growth and the potential for prolonged photocathode lifetime. However, a consequence of operating at higher voltages is the increased likelihood of field emission or breakdown, both of which are unacceptable. Highlights of the R and D studies leading toward a production 200keV GaAs photogun for CEBAF will be presented.

  20. SSRL photocathode RF gun test stand

    International Nuclear Information System (INIS)

    Hernandez, M.; Baltay, M.; Boyce, A.

    1995-01-01

    A photocathode RF gun test stand designed for the production and study of high brightness electron beams will be constructed at SSRL. The beam will be generated from a laser driven third generation photocathode RF gun being developed in collaboration with BNL, LBL, and UCLA. The 3-5 [MeV] beam from the gun will be accelerated using a SLAC three meter S-band accelerator section, in order to achieve the desired low emittance beam, emittance compensation with solenoidal focusing will be employed

  1. Generation of helical electron beams by a nonadiabatic gun

    International Nuclear Information System (INIS)

    Barroso, J.J.; Stellati, C.

    1996-01-01

    The design of a non-adiabatic gun to produce a 10A, 50kV hollow laminar electron beam for gyrotron applications is reported. The beam is extracted from the emitting ring in a direction parallel to the axial guide magnetic field and then propagates across the radial electric field in the anode gap. The electrons are thereby given a transverse velocity upon passing through the modulation anode region where an electrostatic pumping mechanism takes place, so that a considerable amount of the electron energy is converted to transverse kinetic energy. Such a beam extraction method gives rise to favourable features that are examined throughout the work. The dynamics of hollow electron beams with gyromotion propagating down a cylindrical drift tube are also analysed. Due to the action of the beam's self-space charge field, the transverse velocity spread has an oscillatory behaviour along the drift tube wherein the spatial automodulation period shortens with increasing current. Numerical simulation results indicate that even at a 10A beam current, the resulting transverse velocity spread is still less than the spread for a zero beam current. (UK)

  2. Design and Analysis of an Electron Gun/Booster and Free Electron Laser Optical Theory

    Science.gov (United States)

    2010-09-01

    105 65. Stanford DC gun equipotentials . . . . . . . . . . . . . . . . . . . . . . 106 66. Energy plots for various electrode ratios...222 121. Graphical Cross-correlation Demonstration . . . . . . . . . . . . . . . . 223 122. 2D cross-correlation surface ...them enough energy to escape the metal’s surface . Once free of the metal, the electric field accelerates the electrons toward an anode. If the anode is

  3. The Use of an Electron Microchannel as a Self-Extracting and Focusing Plasma Cathode Electron Gun

    Science.gov (United States)

    Cornish, S.; Khachan, J.

    2016-02-01

    A new and simple type of electron gun is presented. Unlike conventional electron guns, which require a heated filament or extractor, accelerator and focusing electrodes, this gun uses the collimated electron microchannels of an inertial electrostatic confinement (IEC) discharge to achieve the same outcome. A cylindrical cathode is placed coaxially within a cylindrical anode to create the discharge. Collimated beams of electrons and fast neutrals emerge along the axis of the cylindrical cathode. This geometry isolates one of the microchannels that emerge in a negatively biased IEC grid. The internal operating pressure range of the gun is 35-190 mTorr. A small aperture separates the gun from the main vacuum chamber in order to achieve a pressure differential. The chamber was operated at pressures of 4-12 mTorr. The measured current produced by the gun was 0.1-3 mA (0.2-14 mA corrected measurement) for discharge currents of 1-45 mA and discharge voltages of 0.5-12 kV. The collimated electron beam emerges from the aperture into the vacuum chamber. The performance of the gun is unaffected by the pressure differential between the vacuum chamber and the gun. This allows the aperture to be removed and the chamber pressure to be equal to the gun pressure if required.

  4. The Use of an Electron Microchannel as a Self-Extracting and Focusing Plasma Cathode Electron Gun

    International Nuclear Information System (INIS)

    Cornish, S.; Khachan, J.

    2016-01-01

    A new and simple type of electron gun is presented. Unlike conventional electron guns, which require a heated filament or extractor, accelerator and focusing electrodes, this gun uses the collimated electron microchannels of an inertial electrostatic confinement (IEC) discharge to achieve the same outcome. A cylindrical cathode is placed coaxially within a cylindrical anode to create the discharge. Collimated beams of electrons and fast neutrals emerge along the axis of the cylindrical cathode. This geometry isolates one of the microchannels that emerge in a negatively biased IEC grid. The internal operating pressure range of the gun is 35-190 mTorr. A small aperture separates the gun from the main vacuum chamber in order to achieve a pressure differential. The chamber was operated at pressures of 4-12 mTorr. The measured current produced by the gun was 0.1-3 mA (0.2-14 mA corrected measurement) for discharge currents of 1-45 mA and discharge voltages of 0.5-12 kV. The collimated electron beam emerges from the aperture into the vacuum chamber. The performance of the gun is unaffected by the pressure differential between the vacuum chamber and the gun. This allows the aperture to be removed and the chamber pressure to be equal to the gun pressure if required. (paper)

  5. An ultrafast nanotip electron gun triggered by grating-coupled surface plasmons

    Energy Technology Data Exchange (ETDEWEB)

    Schröder, Benjamin; Sivis, Murat; Bormann, Reiner; Schäfer, Sascha; Ropers, Claus, E-mail: cropers@gwdg.de [4th Physical Institute - Solids and Nanostructures, University of Göttingen, Friedrich-Hund-Platz 1, 37077 Göttingen (Germany)

    2015-12-07

    We demonstrate multiphoton photoelectron emission from gold nanotips induced by nanofocusing surface plasmons, resonantly excited on the tip shaft by a grating coupler. The tip is integrated into an electron gun assembly, which facilitates control over the spatial emission sites and allows us to disentangle direct grating emission from plasmon-triggered apex emission. The nanoscale source size of this electron gun concept enables highly coherent electron pulses with applications in ultrafast electron imaging and diffraction.

  6. Thermal and mechanical modelling of a mig-type electron gun

    International Nuclear Information System (INIS)

    Patire Junior, H.; Castro, J.J.B. de

    1995-01-01

    A thermal and mechanical modelling of a magnetron injection electron gun has been made to minimize the temperature distribution in the gun elements while keeping the required operating temperature at 1000 0 C of the emitter. Appropriate materials were selected to reduce thermal losses and to improve the gun design from a constructional point of view aiming at extending the capabilities of the gun. A software has been used to simulate a thermal model considering the three processes of thermal transfer and the influence of the physical properties of the materials used. (author). 8 refs., 2 figs, 2 tabs

  7. Stimulation of plasma waves by electron guns on the ISEE-1 satellite

    International Nuclear Information System (INIS)

    Lebreton, J.P.; Anderson, R.; Harvey, C.; Torbert, R.

    1982-01-01

    This chapter describes typical observations of the waves stimulated during the electron injections, when the spacecraft is passing through the magnetosphere, the magnetosheath and the solar wind. Topics considered include orbits of gun electrons, an electric field antenna, gun operation in the magnetosphere, natural waves in the magnetosheath and the solar wind, gun operation magnetosheath, and gun operation in the solar wind. A coupling mechanism between the electron plasma mode and streaming electrons with energies higher than the thermal speed of the cold electron population is proposed to explain the observations above the electron plasma frequency. It is demonstrated that on board the ISEE-1 satellite, the injection of an electron beam current of the order of 10 to 60 251A with energies ranging from 0 to 40 eV produced enhancements in the electric wave spectrum

  8. An electron gun with replaceable cathode-heater assembly for an E-beam irradiator

    International Nuclear Information System (INIS)

    Wu Xunlei; Yu Xiaojuan; Jiang Zhenbo

    2011-01-01

    A new type of electron guns has been developed for a 10 MeV 1.5 mA linac for radiation processing. The specifications required are: cathode voltage 60 kV, peak beam current 550-600 mA, spot size 4 mm, and working distance 60 mm. Particularly, this electron gun is advantageous in its replaceable cathode-heater assembly. This helps the customers to reduce their operation cost. The Egun and Mafia codes were used to simulate electromagnetic fields and electron trajectories. The guns were produced in the same technology of our klystron production. Design specifications of the gun were achieved in the beam current test and beam spot test. The first gun of this type has been working on an linac for about 3000 hours. (authors)

  9. Low emittance electron beam formation with a 17 GHz RF gun

    Directory of Open Access Journals (Sweden)

    W. J. Brown

    2001-08-01

    Full Text Available We report on electron beam quality measurement results from the Massachusetts Institute of Technology 17 GHz RF gun experiment. The 1.5 cell RF gun uses a solenoid for emittance compensation. It has produced bunch charges up to 0.1 nC with beam energies up to 1 MeV. The normalized rms emittance of the beam after 35 cm of transport from the gun has been measured by a slit technique to be 3π mm mrad for a 50 pC bunch. This agrees well with PARMELA simulations at these beam energies. At the exit of the electron gun, we estimate the emittance to be about 1π mm mrad, which corresponds to a beam brightness of about 80 A/(π mm mrad^{2}. Improved beam quality should be possible with a higher energy output electron beam from the gun.

  10. Engineering Design and Fabrication of an Ampere-Class Superconducting Photocathode Electron Gun

    International Nuclear Information System (INIS)

    Ben-Zvi, I.

    2008-01-01

    Over the past three years, Advanced Energy Systems and Brookhaven National Laboratory (BNL) have been collaborating on the design of an Ampere- class superconducting photocathode electron gun. BNL performed the physics design of the overall system and RF cavity under prior programs. Advanced Energy Systems (AES) is currently responsible for the engineering design and fabrication of the electron gun under contract to BNL. We will report on the engineering design and fabrication status of the superconducting photocathode electron gun. The overall configuration of the cryomodule will be reviewed. The layout of the hermitic string, space frame, shielding package, and cold mass will be discussed. The engineering design of the gun cavity and removable cathode will be presented in detail and areas of technical risk will be highlighted. Finally, the fabrication sequence and fabrication status of the gun cavity will be discussed

  11. Modelling and design of high compression electron guns for EBIS/T charge breeders

    CERN Document Server

    AUTHOR|(CDS)2087190; Zschornack, G.; Lettry, J.; Wenander, F.

    In this thesis the optimization of the REXEBIS charge breeder at the ISOLDE facility is presented. REXEBIS in its current state provides a current density of 200A/cm² inside the trapping region at 2 T and will be optimized to the physical limit of its design. To overcome this limit a new electron gun, the HEC² gun, was designed in collaboration with the BNL and is in commission at TestEBIS. This electron gun promises a current density of >10 kA/cm², which decreases the charge breeding time significantly. This thesis presents novel simulation techniques supporting the commissioning phase by explaining the sources of occurring loss current and, in addition, evaluate the currently installed collector for compatibility with the HEC2 gun operating at its design limit. The experience gained from the commission of the HEC² gun and the established numerical techniques lead to the development of a smaller high-compression electron gun for medical purposes, the MEDeGUN. This electron gun should provide a high-quali...

  12. Simulation of Electron Beam Trajectory of Thermionic Electron Gun Type with Pierce Electrode

    International Nuclear Information System (INIS)

    Suprapto; Djoko-SP; Djasiman

    2000-01-01

    The simulation of electron beam trajectory for electron gun of electron beam machine has been done. The simulation is carried out according to mechanical design of the electron gun. The simulation is carried out by using the software made by Andrzej Soltan Institute for Nuclear Studies, Swierk-Poland. The result obtained from simulation is approximately parallel electron beam trajectory of 20 mA beam current at 0.66 kV anode voltage, 15 mm cathode-anode distance and 67.5 o cathode angle. Arrangement of electron gun and accelerating tube with 15 kV voltage between anode and the first electrode of accelerating tube yields focus distance of 34 mm from the to cathode. To obtain the approximately parallel beam trajectory which has -0.03 o entrance angles to accelerating tube, the suitable cathode-anode voltage is 12.66 kV. With the entrance angle of -0.03 o it is expected that the electron beam can be accelerated and the beam profile has a small divergence after passing the accelerating tube. (author)

  13. Design of 120 MW beam power electron gun for high power klystron

    International Nuclear Information System (INIS)

    Zhou Zusheng; Dong Dong

    2005-01-01

    An electron gun was designed and the beam optics for a China-made 50 MW klystron was simulated. The electron gun ceramic cylinder was designed and optimized. The China-made cathode was replaced with an imported one to lessen evaporation and arcing. The high voltage (320 kV) of the cathode was increased to meet the klystron output power demand and a low electric field strength (22.1 kV/mm) electron gun was designed to avoid the high power operation which damaged the ceramic cylinder. The klystron output power was increased and life span extended. (authors)

  14. Electron-optical system of 200 kV gun for the VEPP-5 preinjector

    International Nuclear Information System (INIS)

    Akimov, V.E.; Kazarezov, I.V.; Tiunov, M.A.

    2004-01-01

    The electron gun with a new electron-optical system to match project parameters of the VEPP-5 preinjector is described. The gun produces the current with 10 A amplitude, pulse duration 2...3 ns at half-height and electron energy 200 keV. The gun has a dispenser cathode 20 mm in diameter and 100 mm spherical radius. The current control is performed by means of molybdenum equipotential grid with the cell size 0.4 centre dot 0.4 mm and optical transparency of about 0.68. The experimental results obtained are in good agreement with project parameters

  15. Heating filament system of a Mig-type electron gun for a 35 GHz, 100 k W gyrotron

    International Nuclear Information System (INIS)

    Patire Junior, H.; Barroso, J.J.; Spassovsky, I.P.; Rossi, J.O.

    1993-01-01

    Cathode temperature tests of a Mig-type electron gun have been performed to determine the temperature of the electron emitting surface as a function of heater voltage and current. The test have been conducted partway through the construction phase of the gun as a means to minimize both the necessary heater input power and to reduce radiating of gun components. (author)

  16. Electron bunch structure in energy recovery linac with high-voltage dc photoelectron gun

    Directory of Open Access Journals (Sweden)

    Y. M. Saveliev

    2016-09-01

    Full Text Available The internal structure of electron bunches generated in an injector line with a dc photoelectron gun is investigated. Experiments were conducted on the ALICE (accelerators and lasers in combined experiments energy recovery linac at Daresbury Laboratory. At a relatively low dc gun voltage of 230 kV, the bunch normally consisted of two beamlets with different electron energies, as well as transverse and longitudinal characteristics. The beamlets are formed at the head and the tail of the bunch. At a higher gun voltage of 325 kV, the beam substructure is much less pronounced and could be observed only at nonoptimal injector settings. Experiments and computer simulations demonstrated that the bunch structure develops during the initial beam acceleration in the superconducting rf booster cavity and can be alleviated either by increasing the gun voltage to the highest possible level or by controlling the beam acceleration from the gun voltage in the first accelerating structure.

  17. JAERI 200 kV electron gun with an NEA-GaAs photocathode

    International Nuclear Information System (INIS)

    Nishitani, Tomohiro; Minehara, Eisuke J.; Hajima, Ryoichi; Nagai, Ryoji; Sawamura, Masaru; Nishimori, Nobuyuki; Kikuzawa, Nobuhiro; Yamauchi, Toshihiko

    2004-01-01

    The photocathode DC-gun with high average current, low beam emittance and long operational lifetime is considered to be indispensable for ERL-FEL. We have started the development program of a 200 keV electron gun with the NEA-GaAs photocathode for the first time in JAERI. In order to long an NEA surface lifetime, the JAERI 200 kV electron gun system consists of a 200 kV DC-gun chamber on extreme high vacuum condition and an NEA activation chamber with load-lock system. We report the goal of photocathode DC-gun R and D and the schedule of a developmental program. (author)

  18. Convective and conduction heat transfer study on a mig-type electron gun

    International Nuclear Information System (INIS)

    Patire Junior, H.; Barroso, J.J.

    1996-01-01

    A convective and conducting heat transfer study of a magnetron injection electron gun has been made to minimize the temperature distribution in the gun elements while keeping the required operating temperature at 1000 0 C of the emitter. Appropriate materials were selected to reduce thermal losses and to improve the gun design from a constructional point of view aiming at extending the capabilities of the electron gun. A thermal probe to determine the air velocity and the convective heat transfer coefficient has been constructed to determine the external boundary condition of the ceramic shell and external flanges. A study the contact resistance for all the gun elements has been made to minimize the conduction thermal losses. A software has been used to simulate a thermal model considering the three processes of thermal transfer, namely, conduction, convection and radiation and the influence of the physical properties of the materials used. (author). 7 refs., 5 figs., 1 tab

  19. Three-electrode pulse electron gun with currents up to 250 A

    International Nuclear Information System (INIS)

    Grigor'ev, Yu.V.; Shanturin, L.P.

    1977-01-01

    The design and operating conditions of a pulsed electron gun are described. The electron gun has three electrodes: a cathode, an anode and a control electrode in the form of a grid. The cathode is made from lanthanum hexaboride, which ensures its operation in a low vacuum at a temperature of 1,700 deg C. The control electrode and anode grid are fabricated from sheet tantalum. The anode-grid characteristics of the gun are given. It is shown that at an accelerating voltage of 100 kV, a temperature of 1,700 deg C and a zero control electrode potential the beam current is 250 A

  20. Study of an electron gun for metal evaporation

    International Nuclear Information System (INIS)

    Silva, R. da.

    1983-01-01

    In order to design a eletron gun with a long strip beam, an analysis was done using electrostatic lenses. Due the effects of space charge, it was indicated a beam with low current and high energy. (Author) [pt

  1. Pulsed WIP electron gun. Fabrication phase 1 x 40 cm and 1 x 70 cm cooled WIP electron gun. Final report, March 1979-December 1980

    International Nuclear Information System (INIS)

    Wakalopulos, G.

    1980-01-01

    An electron gun capable of long-run operation at 10 KHz and 1 A/cm 2 has been fabricated and tested. Pulse widths of 200 to 600 nsec and a total life of greater than 10 7 shots have been demonstrated. During the acceptance tests, the electron gun was operated at a total average power of 20 KW for 30 minutes. This basically satisfied the contract requirements. To establish some upper limit of the gun's capability, the device was operated at a repetition rate of 3.5 KHz at a total average power of 54.5 KW for greater than 10 minutes. During these tests, no high voltage breakdown occurred after the device was processed. The beam uniformity at high repetition rates is +-10% and the efficiency is 50%

  2. Study of the Welding Electron Gun Optical Properties for Work Piece Imaging

    Czech Academy of Sciences Publication Activity Database

    Vlček, Ivan

    2009-01-01

    Roč. 44, 5-6 (2009), s. 70-72 ISSN 0861-4717 R&D Projects: GA AV ČR KAN300100702 Institutional research plan: CEZ:AV0Z20650511 Keywords : electron beam welding * electron gun * electron optics design Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering

  3. Secondary emission ion analyzer provided with an electron gun for insulating material analysis

    International Nuclear Information System (INIS)

    Blanchard, Bruno; Carrier, Patrick; Marguerite, J.-L.; Rocco, J.-C.

    1976-01-01

    This invention relates to a secondary emission ion analyser, fitted with an electron gun. It is used in the mass spectrometry analysis of electrically insulating bodies. It has already been suggested to bombard the target with an electron beam in conjunction with the beam of primary particles, in order to reduce the space charge near the target. The object of this invention is the application of this known process to appliances of the ion analyser type with a high electric field near the target. Its main characteristic is the use of an electron gun emitting an electron beam through the extraction lens placed opposite the target. The extraction electric field influences the path of the electrons but the electric and mechanical specifications of the electron gun in the invention are such that the target is correctly sprayed by the electron beam [fr

  4. Quantum efficiency temporal response and lifetime of a GaAs cathode in SRF electron gun

    Energy Technology Data Exchange (ETDEWEB)

    Wang, E.; Ben-Zvi, I.; Kewisch, J.; Burrill, A.; Rao, T.; Wu, Q.; Holmes, D.

    2010-05-23

    RF electron guns with a strained super lattice GaAs cathode can generate polarized electron beam of higher brightness and lower emittance than do DC guns, due to their higher field gradient at the cathode's surface. In a normal conducting RF gun, the extremely high vaccum required by these cathodes can not be met. We report on an experiment with a superconducting SRF gun, which can maintain a vacuum of nearly 10-12 torr because of cryo-pumping at the temperature of 4.2K. With conventional activation, we obtained a QE of 3% at 532 nm, with lifetime of nearly 3 days in the preparation chamber. We plan to use this cathode in a 1.3 GHz 1/2 cell SRF gun to study its performance. In addition, we studied the multipacting at the location of cathode. A new model based on the Forkker-Planck equation which can estimate the bunch length of the electron beam is discussed in this paper. Future particle accelerators such as eRHIC and ILC require high brightness, high current polarized electrons Recently, using a superlattice crystal, the maximum polarization of 95% was reached. Activation with Cs,O lowers the electron affinity and makes it energetically possible for all the electrons excited in to the conduction band and reach the surface to escape into the vacuum. Presently the polarized electron sources are based on DC gun, such as that at the CEBAF at Jlab. In these devices, the life time of the cathode is extended due to the reduced back bombardment in their UHV conditions. However, the low accelerating gradient of the DC guns lead to poor longitudinal emittance. The higher accelerating gradient of the RF gun generates low emittance beams. Superconducting RF guns combine the excellent vacuum conditions of the DC guns with the higher accelerating gradients of the RF guns and provide potentially a long lived cathode with very low transverse and longitudinal emittance. In our work at BNL, we successfully activated the GaAs. The quantum efficient is 3% at 532 nm and is

  5. Quantum efficiency temporal response and lifetime of a GaAs cathode in SRF electron gun

    International Nuclear Information System (INIS)

    Wang, E.; Ben-Zvi, I.; Kewisch, J.; Burrill, A.; Rao, T.; Wu, Q.; Holmes, D.

    2010-01-01

    RF electron guns with a strained super lattice GaAs cathode can generate polarized electron beam of higher brightness and lower emittance than do DC guns, due to their higher field gradient at the cathode's surface. In a normal conducting RF gun, the extremely high vaccum required by these cathodes can not be met. We report on an experiment with a superconducting SRF gun, which can maintain a vacuum of nearly 10-12 torr because of cryo-pumping at the temperature of 4.2K. With conventional activation, we obtained a QE of 3% at 532 nm, with lifetime of nearly 3 days in the preparation chamber. We plan to use this cathode in a 1.3 GHz 1/2 cell SRF gun to study its performance. In addition, we studied the multipacting at the location of cathode. A new model based on the Forkker-Planck equation which can estimate the bunch length of the electron beam is discussed in this paper. Future particle accelerators such as eRHIC and ILC require high brightness, high current polarized electrons Recently, using a superlattice crystal, the maximum polarization of 95% was reached. Activation with Cs,O lowers the electron affinity and makes it energetically possible for all the electrons excited in to the conduction band and reach the surface to escape into the vacuum. Presently the polarized electron sources are based on DC gun, such as that at the CEBAF at Jlab. In these devices, the life time of the cathode is extended due to the reduced back bombardment in their UHV conditions. However, the low accelerating gradient of the DC guns lead to poor longitudinal emittance. The higher accelerating gradient of the RF gun generates low emittance beams. Superconducting RF guns combine the excellent vacuum conditions of the DC guns with the higher accelerating gradients of the RF guns and provide potentially a long lived cathode with very low transverse and longitudinal emittance. In our work at BNL, we successfully activated the GaAs. The quantum efficient is 3% at 532 nm and is expected

  6. Design and experimental results of a new electron gun using a magnetic multipole plasma generator

    International Nuclear Information System (INIS)

    Tanaka, S.; Yokoyama, K.; Akiba, M.; Araki, M.; Dairaku, M.; Inoue, T.; Mizuno, M.; Okumura, Y.; Ohara, Y.; Seki, M.; Watanabe, K.

    1991-01-01

    A new electron gun utilizing a magnetic multipole plasma generator was designed and fabricated as the heat source of the high heat flux test facility, called JEBIS (JAERI electron beam irradiation stand). By changing the acceleration grids, this electron gun is able to produce a pencil to a sheetlike electron beams up to 4 A at 100 keV for 1 ms to continuous mode. In this electron gun, magnetic lens system is not adopted to focus the electron beam, but the space charge neutralization effect by the beam plasma produced downstream of the electron gun is utilized to prevent the blow-up of the electron beam. In addition, high permeability metal is embedded in the first and the second grids to magnetically shield the earth field and the stray field from the beam bending magnet. It was experimentally demonstrated that wide range of heat flux from 0.2 MW/m 2 to over 2000 MW/m 2 can be realized at the test sample position about 1.7 m downstream of the electron gun

  7. Analysis of thermionic DC electron gun for 125 MeV linac

    International Nuclear Information System (INIS)

    Kanno, K.; Sato, Isamu; Sato, K.

    2000-01-01

    The beam trace calculation for the 100 kV thermionic DC electron gun with EIMAC 646E cathode, which is currently used for the 125 MeV linac at Nihon University, has been performed using EGUN code. The result showed a strong focus of the beam at the exit of the anode. A better geometry of the gun has been investigated by varying the shape of the wehnelt electrode. Also the trace calculation has been performed for the case of EIMAC 646B, which showed a considerably small emittance compared with that estimated for the present gun. (author)

  8. Analysis of thermionic DC electron gun for 125 MeV linac

    Energy Technology Data Exchange (ETDEWEB)

    Kanno, K. [Graduate School of Science and Technology, Nihon Univ., Funabashi, Chiba (Japan); Sato, Isamu; Sato, K. [Nihon Univ., Funabashi, Chiba (Japan). Atomic Energy Research Inst] [and others

    2000-07-01

    The beam trace calculation for the 100 kV thermionic DC electron gun with EIMAC 646E cathode, which is currently used for the 125 MeV linac at Nihon University, has been performed using EGUN code. The result showed a strong focus of the beam at the exit of the anode. A better geometry of the gun has been investigated by varying the shape of the wehnelt electrode. Also the trace calculation has been performed for the case of EIMAC 646B, which showed a considerably small emittance compared with that estimated for the present gun. (author)

  9. Generation of Low-Energy High-Current Electron Beams in Plasma-Anode Electron Guns

    Science.gov (United States)

    Ozur, G. E.; Proskurovsky, D. I.

    2018-01-01

    This paper is a review of studies on the generation of low-energy high-current electron beams in electron guns with a plasma anode and an explosive-emission cathode. The problems related to the initiation of explosive electron emission under plasma and the formation and transport of high-current electron beams in plasma-filled systems are discussed consecutively. Considerable attention is given to the nonstationary effects that occur in the space charge layers of plasma. Emphasis is also placed on the problem of providing a uniform energy density distribution over the beam cross section, which is of critical importance in using electron beams of this type for surface treatment of materials. Examples of facilities based on low-energy high-current electron beam sources are presented and their applications in materials science and practice are discussed.

  10. Heat load of a GaAs photocathode in an SRF electron gun

    International Nuclear Information System (INIS)

    Wang Erdong; Zhao Kui; Jorg Kewisch; Ilan Ben-Zvi; Andrew Burrill; Trivini Rao; Wu Qiong; Animesh Jain; Ramesh Gupta; Doug Holmes

    2011-01-01

    A great deal of effort has been made over the last decades to develop a better polarized electron source for high energy physics. Several laboratories operate DC guns with a gallium arsenide photocathode, which yield a highly polarized electron beam. However, the beam's emittance might well be improved by using a superconducting radio frequency (SRF) electron gun, which delivers beams of a higher brightness than that from DC guns because the field gradient at the cathode is higher. SRF guns with metal and CsTe cathodes have been tested successfully. To produce polarized electrons, a Gallium-Arsenide photo-cathode must be used: an experiment to do so in a superconducting RF gun is under way at BNL. Since a bulk gallium arsenide (GaAs) photocathode is normal conducting, a problem arises from the heat load stemming from the cathode. We present our measurements of the electrical resistance of GaAs at cryogenic temperatures, a prediction of the heat load and verification by measuring the quality factor of the gun with and without the cathode at 2 K. We simulate heat generation and flow from the GaAs cathode using the ANSYS program. By following the findings with the heat load model, we designed and fabricated a new cathode holder (plug) to decrease the heat load from GaAs. (authors)

  11. Heat load of a P-doped GaAs photocathode in SRF electron gun

    International Nuclear Information System (INIS)

    Wang, E.; Ben-Zvi, I.; Kewisch, J.; Burrill, A.; Rao, T.; Wu, Q.; Jain, A.; Gupta, R.; Holmes, D.

    2010-01-01

    Many efforts were made over the last decades to develop a better polarized electron source for the high energy physics. Several laboratories operate DC guns with the Gallium-Arsenide photo-cathode, which yield a highly polarized electron beam. However, the beam's emittance might well be improved using a Superconducting RF electron gun, which delivers beams of higher brightness than DC guns does, because the field gradient at the cathode is higher. SRF guns with metal cathodes and CsTe cathodes have been tested successfully. To produce polarized electrons, a Gallium-Arsenide photo-cathode must be used: an experiment to do so in a superconducting RF gun is under way at BNL. Since the cathode will be normal conducting, the problem about the heat load stemming from the cathode arises. We present our measurements of the electrical resistance of GaAs at cryogenic temperatures, a prediction of the heat load and the verification by measuring the quality factor of the gun with and without cathode.

  12. Development of an S-band cavity-type beam position monitor for a high power THz free-electron laser

    Energy Technology Data Exchange (ETDEWEB)

    Noh, Seon Yeong; Kim, Eun-San, E-mail: eskim1@knu.ac.kr; Hwang, Ji-Gwang; Heo, A.; Won, Jang Si [Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Vinokurov, Nikolay A.; Jeong, Young UK, E-mail: yujung@kaeri.re.kr; Hee Park, Seong; Jang, Kyu-Ha [WCI Center for Quantum-Beam-based Radiation Research, Korea Atomic Energy Research Institute, 989-111 Daedeok-Daero, Yuseong-gu, Daejeon (Korea, Republic of)

    2015-01-15

    A cavity-type beam position monitor (BPM) has been developed for a compact terahertz (THz) free-electron laser (FEL) system and ultra-short pulsed electron Linac system at the Korea Atomic Energy Research Institute (KAERI). Compared with other types of BPMs, the cavity-type BPM has higher sensitivity and faster response time even at low charge levels. When electron beam passes through the cavity-type BPM, it excites the dipole mode of the cavity of which amplitude depends linearly on the beam offset from the center of the cavity. Signals from the BPM were measured as a function of the beam offset by using an oscilloscope. The microtron accelerator for the KAERI THz FEL produces the electron beam with an energy of 6.5 MeV and pulse length of 5 μs with a micropulse of 10-20 ps at the frequency of 2.801 GHz. The macropulse beam current is 40 mA. Because the microtron provides multi-bunch system, output signal would be the superposition of each single bunch. So high output signal can be obtained from superposition of each single bunch. The designed position resolution of the cavity-type BPM in multi-bunch is submicron. Our cavity-type BPM is made of aluminum and vacuum can be maintained by indium sealing without brazing process, resulting in easy modification and cost saving. The resonance frequency of the cavity-type BPM is 2.803 GHz and the cavity-type BPM dimensions are 200 × 220 mm (length × height) with a pipe diameter of 38 mm. The measured position sensitivity was 6.19 (mV/mm)/mA and the measured isolation between the X and Y axis was −39 dB. By measuring the thermal noise of system, position resolution of the cavity-type BPM was estimated to be less than 1 μm. In this article, we present the test results of the S-band cavity-type BPM and prove the feasibility of the beam position measurement with high resolution using this device.

  13. Development of an S-band cavity-type beam position monitor for a high power THz free-electron laser

    Science.gov (United States)

    Noh, Seon Yeong; Kim, Eun-San; Hwang, Ji-Gwang; Heo, A.; won Jang, Si; Vinokurov, Nikolay A.; Jeong, Young UK; Hee Park, Seong; Jang, Kyu-Ha

    2015-01-01

    A cavity-type beam position monitor (BPM) has been developed for a compact terahertz (THz) free-electron laser (FEL) system and ultra-short pulsed electron Linac system at the Korea Atomic Energy Research Institute (KAERI). Compared with other types of BPMs, the cavity-type BPM has higher sensitivity and faster response time even at low charge levels. When electron beam passes through the cavity-type BPM, it excites the dipole mode of the cavity of which amplitude depends linearly on the beam offset from the center of the cavity. Signals from the BPM were measured as a function of the beam offset by using an oscilloscope. The microtron accelerator for the KAERI THz FEL produces the electron beam with an energy of 6.5 MeV and pulse length of 5 μs with a micropulse of 10-20 ps at the frequency of 2.801 GHz. The macropulse beam current is 40 mA. Because the microtron provides multi-bunch system, output signal would be the superposition of each single bunch. So high output signal can be obtained from superposition of each single bunch. The designed position resolution of the cavity-type BPM in multi-bunch is submicron. Our cavity-type BPM is made of aluminum and vacuum can be maintained by indium sealing without brazing process, resulting in easy modification and cost saving. The resonance frequency of the cavity-type BPM is 2.803 GHz and the cavity-type BPM dimensions are 200 × 220 mm (length × height) with a pipe diameter of 38 mm. The measured position sensitivity was 6.19 (mV/mm)/mA and the measured isolation between the X and Y axis was -39 dB. By measuring the thermal noise of system, position resolution of the cavity-type BPM was estimated to be less than 1 μm. In this article, we present the test results of the S-band cavity-type BPM and prove the feasibility of the beam position measurement with high resolution using this device.

  14. Lifetime measurements using the Jefferson Lad Load-Lock Electron Gun

    International Nuclear Information System (INIS)

    J. Grames; P. Adderley; M. Baylac; J. Brittian; D. Charles; J. Clark; J. Hansknecht; M. Poelker; M. Stutzman; K. Surles-Law

    2000-01-01

    Lifetime measurements of bulk GaAs using a 100 kV load-lock electron gun and beam line were made. Initial tests used anodized samples to study lifetime under various conditions (gun vacuum, laser spot location, activated area). Subsequent tests used a mechanical mask to limit the active area and included improved monitoring of the gun chamber and beam line vacuum pressure. Results of these measurements support claims made at past workshops, namely photocathode lifetime improves when gun vacuum is enhanced and when electron emission from the edge of the photocathode is eliminated. The dependence upon laser spot location is less certain. Tests studying lifetime at higher beam intensity (I ∼ 8 mA) have begun

  15. Thermal deformation analysis and test of electron gun for high power klystron

    International Nuclear Information System (INIS)

    Zhou Zusheng; Chinese Academy of Sciences, Beijing; Dong Dong

    2006-01-01

    A 120 MW pulsed electron gun has been developed for 50 MW China-made klystron. It has a Pierce type dispenser cathode and it scans with a diameter of 85 mm. This paper describes the temperature field distribution in the gun and the gun deformation caused by this distribution by using ANSYS. According to the real complex structure and the energy conversion inside the electron gun, the authors took the thermal conduction as the main energy conversion form and got the temperature field. The coincidence between the temperature field and the structural deformation is also described. The beam optics simulated by EGUN with and without considering deformation is discussed, and the valuable results have been obtained. The high power test results and simulation results are analyzed and compared. (authors)

  16. Power-supply system for high-voltage electron guns with grid control

    International Nuclear Information System (INIS)

    Grigorev, Y.V.

    1985-01-01

    A power-supply system for electron guns with grid control is described which consists of a source of accelerating voltage between 20 and 180 kV with a current of 100 mA and a control circuit for an electron gun that contains a pulse generator having an output voltage of up to 5 kV for pulse durations of 2, 10, 50 and 90 microseconds. The output pulses of the generator are synchronized with a certain phase of the cathode heater current of the gun, and they can be repeated at a frequency between 100 and 0.4 Hz. The system is reliable and resistant to the overloads associated with breakdowns in the gun

  17. Plasma diagnostics by electron guns and electric field probes on ISEE-1

    International Nuclear Information System (INIS)

    Pedersen, A.

    1982-01-01

    The use of electron guns to control the potential of a satellite with conductive surfaces is discussed with reference to the results of the ISEE-1 satellite experiment. The two electron guns carried by the satellite can emit electrons with energies up to 48 eV, and the emitted electron current has a maximum value of 0.5-1.0 mA. The satellite potential, with or without gun operation, can be measured with reference to one or two spherical electric field probes positioned on booms at a distance of 36 m from the satellite. The probes are biased with a negative current from a high-impedance source to be slightly positive (0.5-1.0 V) relative to the plasma, and the spacecraft is normally several volts more positive and can be further positively charged by operating the electron gun. Plasma diagnostics can be carried out by appropriate sweeps of gun currents and energy of emitted electrons to obtain information about density and characteristic energy of ambient electrons. 9 references

  18. An ultrafast electron microscope gun driven by two-photon photoemission from a nanotip cathode

    International Nuclear Information System (INIS)

    Bormann, Reiner; Strauch, Stefanie; Schäfer, Sascha; Ropers, Claus

    2015-01-01

    We experimentally and numerically investigate the performance of an advanced ultrafast electron source, based on two-photon photoemission from a tungsten needle cathode incorporated in an electron microscope gun geometry. Emission properties are characterized as a function of the electrostatic gun settings, and operating conditions leading to laser-triggered electron beams of very low emittance (below 20 nm mrad) are identified. The results highlight the excellent suitability of optically driven nano-cathodes for the further development of ultrafast transmission electron microscopy

  19. Development of a high power electron beam welding gun with replaceable high voltage feed-through insulators

    Energy Technology Data Exchange (ETDEWEB)

    Saha, T.K; Mascarenhas, M.; Kandaswamy, E., E-mail: tanmay@barc.gov.in [Power Beam Equipment Design Section, Bhabha Atomic Research Centre, Mumbai (India)

    2014-07-01

    Ceramic to metal sealed feed-through insulators are commonly used in electron beam welding gun. The above feed-through insulators are susceptible to failure, as the brazing joints in them are not always very strong. Failure in one of these feed-through could render the complete gun unusable. This problem has already been faced in BARC, which led to the development of the electron gun with replaceable feed through insulators. A 24 kW Electron Beam Welding (EBW) gun with indigenous designed replaceable insulators is fabricated in BARC. Emphasis during the design of the gun had been to reduce the use of imported components to zero. This paper describes the design and fabrication of this gun and reports various simulations and tests performed. Beam trajectory of the gun is numerically computed and presented. Weld passes were carried out on stainless steel plates show satisfactory penetrations. (author)

  20. Electron emission and plasma generation in a modulator electron gun using ferroelectric cathode

    International Nuclear Information System (INIS)

    Chen Shutao; Zheng Shuxin; Zhu Ziqiu; Dong Xianlin; Tang Chuanxiang

    2006-01-01

    Strong electron emission and dense plasma generation have been observed in a modulator electron gun with a Ba 0.67 Sr 0.33 TiO 3 ferroelectric cathode. Parameter of the modulator electron gun and lifetime of the ferroelectric cathode were investigated. It was shown that electron emission from Ba 0.67 Sr 0.33 TiO 3 cathode with a positive triggering pulse is a sort of plasma emission. Electrons were emitted by the co-effect of surface plasma and non-compensated negative polarization charges at the surface of the ferroelectric. The element analyses of the graphite collector after emission process was performed to show the ingredient of the plasma consist of Ba, Ti and Cu heavy cations of the ceramic compound and electrode. It was demonstrated the validity of the Child-Langmuir law by introducing the decrease of vacuum gap and increase of emission area caused by the expansion of the surface plasma

  1. Investigations and Applications of Field- and Photo-emitted Electron Beams from a Radio Frequency Gun

    Energy Technology Data Exchange (ETDEWEB)

    Panuganti, SriHarsha [Northern Illinois Univ., DeKalb, IL (United States)

    2015-08-01

    Production of quality electron bunches using e cient ways of generation is a crucial aspect of accelerator technology. Radio frequency electron guns are widely used to generate and rapidly accelerate electron beams to relativistic energies. In the current work, we primarily study the charge generation processes of photoemission and eld emission inside an RF gun installed at Fermilab's High Brightness Electron Source Laboratory (HBESL). Speci cally, we study and characterize second-order nonlinear photoemission from a Cesium Telluride (Cs2Te) semiconductor photocathode, and eld emission from carbon based cathodes including diamond eld emission array (DFEA) and carbon nanotube (CNT) cathodes located in the RF gun's cavity. Finally, we discuss the application experiments conducted at the facility to produce soft x-rays via inverse Compton scattering (ICS), and to generate uniformly lled ellipsoidal bunches and temporally shaped electron beams from the Cs2Te photocathode.

  2. Development of a novel thermionic RF electron gun applied on a compact THz-FEL facility

    Science.gov (United States)

    Hu, T. N.; Pei, Y. J.; Qin, B.; Liu, K. F.; Feng, G. Y.

    2018-04-01

    The current requirements from civil and commercial applications lead to the development of compact free-electron laser (FEL)-based terahertz (THz) radiation sources. A picosecond electron gun plays an important role in an FEL-THz facility and attracts significant attention, as machine performance is very sensitive to initial conditions. A novel thermionic gun with an external cathode (EC) and two independently tunable cavities (ITCs) has been found to be a promising alternative to conventional electron sources due to its remarkable characteristics, and correspondingly an FEL injector can achieve a balance between a compact layout and high brightness benefitting from the velocity bunching properties and RF focusing effects in the EC-ITC gun. Nevertheless, the EC-ITC gun has not been extensively examined as part of the FEL injector in the past years. In this regard, to fill this gap, a development focusing on the experimental setup of an FEL injector based on an EC-ITC gun is described in detail. Before assembly, dynamic beam simulations were performed to investigate the optimal mounting position for the Linac associated with the focusing coils, and a suitable radio-frequency (RF) system was established based on a power coupling design and allocation. The testing bench proved to be fully functional through basic experiments using typical diagnostic approaches for estimating primary parameters. Associated with dynamic beam calculations, a performance evaluation for an EC-ITC gun was established while providing indirect testing results for an FEL injector.

  3. High Brightness Electron Guns for Next-Generation Light Sources and Accelerators

    International Nuclear Information System (INIS)

    H. Bluem; M.D. Cole; J. Rathke; T. Schultheiss; A.M.M. Todd; I. Ben-Zvi; T. Srinivasan-Rao; P. Colestock; D.C. Nguyen; R.L. Wood; L. Young; D. Janssen; J. Lewellen; G. Neil; H.L. Phillips; J.P. Preble

    2004-01-01

    Advanced Energy Systems continues to develop advanced electron gun and injector concepts. Several of these projects have been previously described, but the progress and status of each will be updated. The project closest to completion is an all superconducting RF (SRF) gun, being developed in collaboration with the Brookhaven National Laboratory, that uses the niobium of the cavity wall itself as the photocathode material. This gun has been fabricated and will shortly be tested with beam. The cavity string for a closely-coupled DC gun and SRF cavity injector that is expected to provide beam quality sufficient for proposed ERL light sources and FELs will be assembled at the Jefferson Laboratory later this year. We are also collaboration with Los Alamos on a prototype CW normal-conducting RF gun with similar performance, that will undergo thermal testing in late 2004. Another CW SRF gun project that uses a high quantum efficiency photocathode, similar to the FZ-Rossendorf approach, has just begun. Finally, we will present the RF design and cold test results for a fully axisymmetric, ultra-high-brightness x-band RF gun

  4. Pulsed WIP electron gun. Final report: design phase 1 x 70 cm cooled WIP electron gun, 1 December 1978--2 February 1979

    International Nuclear Information System (INIS)

    Wakalopulos, G.; Gresko, L.

    1979-01-01

    Presented here are design criteria for a full scale (70 cm) WIP electron gun system capable of long run operation with the following specifications: foil area approx. 70 x 1 cm, electron beam current density approx. 1 A/cm 2 , pulse length 2 , voltage -150 kV, voltage droop < 10%, Rep rate approx. 10 KHz, power approx. 20 kW, run time approx. 30 min, and jitter approx. 10 μs

  5. Design of spherical electron gun for ultra high frequency, CW power inductive output tube

    International Nuclear Information System (INIS)

    Kaushik, Meenu; Joshi, L. M.

    2016-01-01

    Inductive Output Tube (IOT) is an amplifier that usually operates in UHF range. It is an electron tube whose basic structure is similar to conventional vacuum devices. This device is widely used in broadcast applications but is now being explored for scientific applications also specifically, particle accelerators and fusion plasma heating purposes. The paper describes the design approach of a spherical gridded electron gun of a 500 MHz, 100 kW CW power IOT. The electron gun structure has been simulated and optimized for operating voltage and current of 40kV and 3.5 A respectively. The electromagnetic analysis of this spherical electron gun has been carried out in CST and TRAK codes.

  6. Design of spherical electron gun for ultra high frequency, CW power inductive output tube

    Energy Technology Data Exchange (ETDEWEB)

    Kaushik, Meenu, E-mail: mkceeri@gmail.com; Joshi, L. M., E-mail: lmj1953@gmail.com [Microwave Tubes Division, CSIR-Central Electronics Engineering Research Institute (CEERI), Pilani, Rajasthan (India); Academy of Scientific and Innovative Research (AcSIR), New Delhi (India)

    2016-03-09

    Inductive Output Tube (IOT) is an amplifier that usually operates in UHF range. It is an electron tube whose basic structure is similar to conventional vacuum devices. This device is widely used in broadcast applications but is now being explored for scientific applications also specifically, particle accelerators and fusion plasma heating purposes. The paper describes the design approach of a spherical gridded electron gun of a 500 MHz, 100 kW CW power IOT. The electron gun structure has been simulated and optimized for operating voltage and current of 40kV and 3.5 A respectively. The electromagnetic analysis of this spherical electron gun has been carried out in CST and TRAK codes.

  7. Synthesis of mig-type electron guns for gyrotrons

    International Nuclear Information System (INIS)

    Castro, J.J.B. de; Montes, A.; Silva, C.A.B.

    1984-01-01

    A synthesis method is used in the design of axially symmetrical guns in the moderate to high space charge regime. Self-consistent equations for the temperature limited emission case are used to represent the beam and solve the internal problem, under the requirement of laminar flow. The external problem is solved by integrating the equations with boundary conditions defined by the analytically extended solutions of the internal problem. This technique will be used in the development of INPE's gyrotron. (Author) [pt

  8. Progress of electron gun systems for the e-/e+ linac at KEK

    International Nuclear Information System (INIS)

    Ohsawa, S.; Ogawa, Y.; Otake, Y.; Yokota, M.; Fukuda, S.; Saito, Y.; Enomoto, A.; Azuma, O.; Iwata, H.; Asami, A.

    1989-01-01

    Several improvements have been made in the electron gun systems of the 2.5 GeV PF linac and the Positron Generator. In the electron gun system of the PF linac, the vacuum system and the focusing system have been modified, and the anode current was increased. In the case of a short pulse beam with a width of 2 ns, the anode current has been more than 200 mA for about a year with a constant pulse voltage output of a grid pulser. Injection time of the electron beam into the Accumulation Ring of TRISTAN has been normally less than 10 s. Meanwhile in the electron gun system of the Positron Generator, improvements have been made mainly in the following two points; (1) a raise of injection voltage of the gun from 115 kV to 150 kV, which was made possible by using a newly designed insulator, and (2) an increase of pulse voltage output of a grid pulser by use of new transistors with a high slew rate. As a result of these improvements, a maximum anode peak current of 12 A with a pulse width of 4 ns can be obtained, which satisfies the design parameters of the gun system. 7 refs., 8 figs

  9. Design and development of line type modulators for high impedance electron gun

    Energy Technology Data Exchange (ETDEWEB)

    Dixit, Kavita P.; Tillu, Abhijit; Chavan, Ramchandra; Yadav, Vivek; Sarukte, Hemant, E-mail: kavidi@barc.gov.in [Accelerator and Pulse Power Division, Bhabha Atomic Research Centre, Mumbai (India)

    2014-07-01

    Conventional line type modulators are routinely used for powering pulsed power microwave devices such as magnetrons and klystrons used for radar, medical and scientific applications. The load impedance (operating point) is fairly well defined in these cases, and makes the design of the discharging circuit of the modulator straight forward. This paper describes the Line type modulators that have been developed and being routinely used for powering the Triode Electron Gun of industrial electron linacs. The beam parameters of such guns are user defined and the pulse current varies from few mA to 800mA (typ). The beam energies requirement varies from 40 keV to 80 keV. Hence the impedance offered by the electron gun to the power source (modulator) is not well defined. The load capacitance which is inclusive of the various stray capacitances along with the intrinsic gun capacitance is ∼ 200-400 pF. This capacitance, which depends on the configuration, shunts the load and makes the effective load highly capacitive with the resistive part varying over a wide range. The paper describes the design and development of conventional line type modulators for powering Electron gun load of the type described above. (author)

  10. Pierce-type electron gun with a large concave LaB6 cathode

    International Nuclear Information System (INIS)

    Shintake, Tumoru; Ohba, Kunio; Matoba, Masaru; Katase, Akira

    1981-01-01

    A Pierce-type electron gun with a concave cathode of lanthanum hexaboride (LaB 6 ) 30 mm in diameter is described. At an accelerating voltage of 3 kV and a cathode temperature of 1340 0 C, a focussed electron beam of DC 300 mA was obtained. (author)

  11. Measures to alleviate the back bombardment effect of thermionic rf electron gun

    International Nuclear Information System (INIS)

    Huang, Y.; Xie, J.

    1991-01-01

    Thermionic rf electron gun finds application as a high brightness electron source for rf linacs. However, cathode heating from back-bombardment effect causes a ramp in the macro-pulse beam current and limit the usable pulse width. Three methods: ring cathode, magnetic deflection and laser assisted heating are studied in theory and in experiment. The results of these studies are reported

  12. 150-MW S-Band klystron program at the Stanford Linear Accelerator Center

    Energy Technology Data Exchange (ETDEWEB)

    Sprehn, D.; Caryotakis, G.; Phillips, R.M. [Stanford Linear Accelerator Center, Stanford Univ., Stanford, CA (United States)

    1997-04-01

    Two S-Band klystrons operating at 150 MW have been designed, fabricated and tested at the Stanford Linear Accelerator Center (SLAC) during the past two years for use in an experimental accelerator at Deutsches Elektronen Synchrotron (DESY) in Hamburg, Germany. Both klystrons operate at the design power, 60 Hz repetition rate, 3 {mu}s pulsewidth, with an efficiency > 40%, and agreement between the experimental results and simulations is excellent. The 535 kV, 700 A electron gun was tested by constructing a solenoidal focused beam-stick which identified a source of oscillation, subsequently engineered out of the klystron guns. Design of the beam-stick and the two klystrons is discussed, along with observation and suppression of spurious oscillations. Differences in design and the resulting performance of the klystrons is emphasized. (author)

  13. Large-area cold-cathode grid-controlled electron gun for Antares

    International Nuclear Information System (INIS)

    Scarlett, W.R.; Andrews, K.; Jansen, J.

    1979-01-01

    The CO 2 laser amplifiers used in the Antares inertial confinement fusion project require large-area radial beams of high-energy electrons to ionize the laser medium before the main discharge pulse is applied. We have designed a grid-controlled, cold-cathode electron gun with a cylindrical anode having a window area of 9.3 m 2 . A full diameter, 1/4 length prototype of the Antares gun has been built and tested. The design details of the Antares electron gun will be presented as well as test results from the prototype. Techniques used for the prevention and control of emission and breakdown from the grid will also be discussed

  14. Design and development of a 6 MW peak, 24 kW average power S-band klystron

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, L.M.; Meena, Rakesh; Nangru, Subhash; Kant, Deepender; Pal, Debashis; Lamba, O.S.; Jindal, Vishnu; Jangid, Sushil Kumar, E-mail: joslm@rediffmail.com [Central Electronics Engineering Research Institute, Council of Scientific and Industrial Research, Pilani (India); Chakravarthy, D.P.; Dixit, Kavita [Bhabha Atomic Research Centre, Mumbai (India)

    2011-07-01

    A 6 MW peak, 24 kW average power S-band Klystron is under development at CEERI, Pilani under an MoU between BARC and CEERI. The design of the klystron has been completed. The electron gun has been designed using TRAK and MAGIC codes. RF cavities have been designed using HFSS and CST Microwave Studio while the complete beam wave interaction simulation has been done using MAGIC code. The thermal design of collector and RF window has been done using ANSYS code. A Gun Collector Test Module (GCTM) was developed before making actual klystron to validate gun perveance and thermal design of collector. A high voltage solid state pulsed modulator has been installed for performance valuation of the tube. The paper will cover the design aspects of the tube and experimental test results of GCTM and klystron. (author)

  15. Design and development of a 6 MW peak, 24 kW average power S-band klystron

    International Nuclear Information System (INIS)

    Joshi, L.M.; Meena, Rakesh; Nangru, Subhash; Kant, Deepender; Pal, Debashis; Lamba, O.S.; Jindal, Vishnu; Jangid, Sushil Kumar; Chakravarthy, D.P.; Dixit, Kavita

    2011-01-01

    A 6 MW peak, 24 kW average power S-band Klystron is under development at CEERI, Pilani under an MoU between BARC and CEERI. The design of the klystron has been completed. The electron gun has been designed using TRAK and MAGIC codes. RF cavities have been designed using HFSS and CST Microwave Studio while the complete beam wave interaction simulation has been done using MAGIC code. The thermal design of collector and RF window has been done using ANSYS code. A Gun Collector Test Module (GCTM) was developed before making actual klystron to validate gun perveance and thermal design of collector. A high voltage solid state pulsed modulator has been installed for performance valuation of the tube. The paper will cover the design aspects of the tube and experimental test results of GCTM and klystron. (author)

  16. Design of a high-brightness, high-duty factor photocathode electron gun

    International Nuclear Information System (INIS)

    Lehrman, I.S.; Birnbaum, I.A.; Fixler, S.Z.; Heuer, R.L.; Siddiqi, S.; Sheedy, E.; Ben-Zvi, I.; Batchelor, K.; Gallardo, J.C.; Kirk, H.G.; Srinivasan-Rao, T.; Warren, G.D.

    1991-09-01

    The proposed UV-FEL user's facility at Brookhaven National Laboratory will require a photocathode gun capable of producing short (< 6 psec) bunches of electrons in high repetition rates (5 kHz), low energy spread (< 1.5.%), a peak current of 300 A (after compression) and a total bunch charge of up to 2 nC. At the highest charge the normalized transverse emittance should be less than 7 π mm-mrad. We are presently designing a gun that is expected to exceed these requirements. This gun will consist of 3 1/2 cells, constructed of GlidCop-15, an aluminum oxide dispersion strengthened copper alloy. The gun will be capable of operating at duty factors in excess of 1%. Extensive beam dynamics studies of the gun were used to determine the effect of varying the length of the first cell, shaping the apertures between cells, and increasing the number of cells. In addition, a detailed thermal and mechanical study of the gun was performed to ensure that the thermal stresses were well within the allowable limits and that copper erosion of the water channels would not occur

  17. Design and modelling of a 5 MeV radio frequency electron gun

    International Nuclear Information System (INIS)

    Batchelor, K.; Sheehan, J.; Woodle, M.

    1988-01-01

    The Accelerator Test Facility (ATF) at Brookhaven National Laboratory is a linac-laser complex for research into laser acceleration and for the generation of coherent radiation from electron beams. In order to achieve the design 50 MeV output emittance (γσ/sub x/σ/sub x/') of less than 3 /times/ 10/sup /minus/5/ m rad a high brightness electron gun is required. This paper describes computations and measurements made on a full scale brass model of a 1-1/2 cell, π-mode, resonant, disc loaded, radiofrequency gun structure which has been designed for this purpose. 7 refs., 9 figs., 6 tabs

  18. Design of convergent pierce electron gun of accelerator for radiation sterilization by the method of synthesis

    International Nuclear Information System (INIS)

    Kong Xiaoxiao; Li Quanfeng

    2003-01-01

    A synthesis technique for the preliminary design of convergent Pierce electron guns is introduced briefly which has a series of advantages over the traditional methods. A thermal cathode electron gun used in the accelerator for radiation sterilization with the synthesis method is redesigned, and the validity of this method is proved. Based on the preliminary design parameters given by the synthesis method, a simulating calculation program, EGUN, was used in the numerical figure design of the focusing electrode and the anode. The final results can meet the engineering requirement as the current being 1A, the normalized emittance being less than 4 mm·mrad, and the final current density showing uniformity

  19. Design of diode electron gun for 250 kW CW klystron

    International Nuclear Information System (INIS)

    Prasad, M.; Pande, S.A.; Hannurkar, P.R.

    2005-01-01

    A 250 kW CW klystron at frequencies 350 MHz and 700 MHz is being developed at Centre for Advanced Technology. These klystrons are required for forthcoming project like 100 MeV proton Linac for Spallation Neutron Source (SNS) as a main rf sources. In order to develop klystrons, we have designed the diode electron gun, which delivers more than 10 A beam current at 50 kV. This paper describes the simulation results of electron gun with computer code EGUN. (author)

  20. Modeling electron beam parameters and plasma interface position in an anode plasma electron gun with hydrogen atmosphere

    Science.gov (United States)

    Krauze, A.; Virbulis, J.; Kravtsov, A.

    2018-05-01

    A beam glow discharge based electron gun can be applied as heater for silicon crystal growth systems in which silicon rods are pulled from melt. Impacts of high-energy charged particles cause wear and tear of the gun and generate an additional source of silicon contamination. A steady-state model for electron beam formation has been developed to model the electron gun and optimize its design. Description of the model and first simulation results are presented. It has been shown that the model can simulate dimensions of particle impact areas on the cathode and anode, but further improvements of the model are needed to correctly simulate electron trajectory distribution in the beam and the beam current dependence on the applied gas pressure.

  1. Electron beam gun with kinematic coupling for high power RF vacuum devices

    Science.gov (United States)

    Borchard, Philipp

    2016-11-22

    An electron beam gun for a high power RF vacuum device has components joined by a fixed kinematic coupling to provide both precise alignment and high voltage electrical insulation of the components. The kinematic coupling has high strength ceramic elements directly bonded to one or more non-ductile rigid metal components using a high temperature active metal brazing alloy. The ceramic elements have a convex surface that mates with concave grooves in another one of the components. The kinematic coupling, for example, may join a cathode assembly and/or a beam shaping focus electrode to a gun stem, which is preferably composed of ceramic. The electron beam gun may be part of a high power RF vacuum device such as, for example, a gyrotron, klystron, or magnetron.

  2. Initial results of the new high intensity electron gun at the Argonne Wakefield Accelerator

    International Nuclear Information System (INIS)

    Conde, M. E.; Gai, W.; Konecny, R.; Power, J. G.; Schoessow, P.; Sun, X.

    2000-01-01

    The authors report on the status of the new short bunch, high intensity electron gun at the Argonne Wakefield Accelerator. The 1-1/2 cell L-band photocathode RF gun is expected to produce 10--100 nC bunches with 2--5 ps rms pulse length and normalized emittance less than 100 mm mrad. The beam energy at the exit of the gun cavity will be in the range 7.5--10 MeV. A standing-wave linac structure operating at the same frequency (1.3 GHz) will increase the beam energy to about 15 MeV. This beam will be used in wakefield acceleration experiments with dielectric loaded structures. These travelling-wave dielectric loaded structures, operating at 7.8 and 15.6 GHz, will be excited by the propagation of single bunches or by trains of up to 32 electron bunches

  3. 3D Modeling Activity for Novel High Power Electron Guns at SLAC

    International Nuclear Information System (INIS)

    Krasnykh, Anatoly

    2003-01-01

    The next generation of powerful electronic devices requires new approaches to overcome the known limitations of existing tube technology. Multi-beam and sheet beam approaches are novel concepts for the high power microwave devices. Direct and indirect modeling methods are being developed at SLAC to meet the new requirements in the 3D modeling. The direct method of solving of Poisson's equations for the multi-beam and sheet beam guns is employed in the TOPAZ 3D tool. The combination of TOPAZ 2D and EGUN (in the beginning) with MAFIA 3D and MAGIC 3D (at the end) is used in an indirect method to model the high power electron guns. Both methods complement each other to get reliable representation of the beam trajectories. Several gun ideas are under consideration at the present time. The collected results of these simulations are discussed

  4. 3D Modeling Activity for Novel High Power Electron Guns at SLAC

    CERN Document Server

    Krasnykh, Anatoly K

    2003-01-01

    The next generation of powerful electronic devices requires new approaches to overcome the known limitations of existing tube technology. Multi-beam and sheet beam approaches are novel concepts for the high power microwave devices. Direct and indirect modeling methods are being developed at SLAC to meet the new requirements in the 3D modeling. The direct method of solving of Poisson's equations for the multi-beam and sheet beam guns is employed in the TOPAZ 3D tool. The combination of TOPAZ 2D and EGUN (in the beginning) with MAFIA 3D and MAGIC 3D (at the end) is used in an indirect method to model the high power electron guns. Both methods complement each other to get reliable representation of the beam trajectories. Several gun ideas are under consideration at the present time. The collected results of these simulations are discussed.

  5. Experimental results from a DC photocathode electron gun for an IR FEL

    International Nuclear Information System (INIS)

    Kehne, D.; Engwall, D.; Legg, R.; Shinn, M.

    1997-01-01

    A 350 keV DC photocathode gun capable of delivering the high-brightness CW electron beam necessary for Jefferson Lab's infrared free-electron laser is described. The gun is to be used with a superconducting radiofrequency linac operating at 1.497 GHz and is mode-locked to the 40th subharmonic of the fundamental using a Nd:YLF drive laser. The gun provides 20--25 ps bunches at up to 135 pC/bunch. Experimental measurements of transverse and longitudinal beam properties are presented. Transverse emittance is measured using a slit-wire scanner emittance meter, and energy spread is measured using the slit and a spectrometer magnet. Longitudinal emittance is measured using a combination of sampling aperture, kicker cavity, slit and spectrometer. Measurements for bunch charges of 135 pC are described and compared with simulations

  6. Single-side electron multipacting at the photocathode in rf guns

    Directory of Open Access Journals (Sweden)

    Jang-Hui Han

    2008-01-01

    Full Text Available Multiple electron impacting (multipacting can take place in rf fields when the rf components are composed of materials with a secondary electron yield greater than one. In rf gun cavities, multipacting may change the properties of the vacuum components or even damage them. First systematic measurements of the multipacting occurring in a photocathode rf gun were made at the Fermilab/NICADD Photoinjector Laboratory in 2000. The multipacting properties were found to depend on the cathode material and the solenoid field configuration. In this study, we measure the multipacting properties in more detail and model the secondary electron generation for numerical simulation. Measurements and simulations for the photoinjectors at Fermilab and DESY are compared. The multipacting takes place at the photocathode in rf guns and is categorized as single-side multipacting. In a low rf field, the electrons emitted from the cathode area do not leave the gun cavity within one rf cycle and have an opportunity to travel back and hit the cathode. The solenoid field distribution in the vicinity of the cathode changes the probability of electron bombardment of the cathode and makes a major contribution to the multipacting behavior.

  7. A 120kV IGBT modulator for driving a Pierce electron gun

    International Nuclear Information System (INIS)

    Earley, Lawrence M.; Brown, Richard W.; Carlson, Randolph L.; Ferguson, Patrick; Haynes, William B.; Kirbie, Hugh C.; Russell, Steven J.; Sigler, Floyd E.; Smirnova, Evgenya I.; Wheat, Robert M. Jr.

    2004-01-01

    An IGBT modulator has been developed to drive a 120 kV, 23 A Pierce electron gun. The modulator is capable of producing pulses up to 10 μs in width at repetition rates up to 10Hz with no active reset. The pulse rise time on the electron gun will be approximately 2 μs and the remaining 8 μs of flattop is tuned to have a ripple of less than 1 percent rms. The modulator technology was developed from a previous 50 kV prototype. The modulator consists of six boards, each with one EUPEC IGBT that drives a single common step-up transformer wound on METGLAS 2605SC cores. The six transformer cores share a common bi-filar output secondary winding. The modulator uses a fiber optic trigger system and has a high voltage cable output with an epoxy receptacle on the oil end and a ceramic receptacle on the vacuum end. The 120 kV electron gun was manufactured by MDS Co. and will be used to generate sheet electron beams from the standard pencil beam produced by the Pierce electron gun.

  8. The design of an electron gun switchable between immersed and Brillouin flowa)

    Science.gov (United States)

    Becker, R.; Kester, O.

    2012-02-01

    An electron gun, which can be switched from immersed flow to Brillouin flow during operation, may have advantages for charge breeders as well as for electron beam ion sources and traps (EBISTs). For EBISTs this allows to change the current density according to the repetition frequency and charge state, for charge breeders and EBISTs a lower current density in immersed flow provides higher acceptance for injected ions, while the higher current density in Brillouin flow results in shorter breeding times and a lower emittance for the extracted beam. Therefore, we have designed such a gun for an EBIS with 5 T central magnetic field and without the use of iron and moving the gun. The gun was placed in the axial fringing field of the 5 T solenoid in such a position that a gate valve can be placed between the gun and the cryostat to allow for simple maintenance. The field at the cathode surface turned out to be only 0.05 T, which is not enough to focus 50 A/cm2 at a few kV. However, if a small normal conducting solenoid is placed over the vacuum tube in position of the gun, a field of 0.1 T may be obtained. With this the use of LaB6 as cathode material results in a magnetic compression of 44 and therewith in a focused current density in the trap region of more than 2000 A/cm2. By reversing the current in the gun solenoid the cathode field can easily compensated to zero. By proper design of the electrodes and the compression region, the gun will be able to deliver a beam in Brillouin flow. While this is interesting by itself - remember the "super-compression" reported on CRYEBIS-I - any magnetic field between zero and the value for immersed flow will result in an electron beam with a wide range of adjustable high current densities. The design tools used have been INTMAG(C) for the calculation of magnetic fields, EGN2(C) for the simulation of the gun and ANALYSE(C) for detailed analysis of the results (for more information see www.egun-igun.com).

  9. The design of an electron gun switchable between immersed and Brillouin flow.

    Science.gov (United States)

    Becker, R; Kester, O

    2012-02-01

    An electron gun, which can be switched from immersed flow to Brillouin flow during operation, may have advantages for charge breeders as well as for electron beam ion sources and traps (EBISTs). For EBISTs this allows to change the current density according to the repetition frequency and charge state, for charge breeders and EBISTs a lower current density in immersed flow provides higher acceptance for injected ions, while the higher current density in Brillouin flow results in shorter breeding times and a lower emittance for the extracted beam. Therefore, we have designed such a gun for an EBIS with 5 T central magnetic field and without the use of iron and moving the gun. The gun was placed in the axial fringing field of the 5 T solenoid in such a position that a gate valve can be placed between the gun and the cryostat to allow for simple maintenance. The field at the cathode surface turned out to be only 0.05 T, which is not enough to focus 50 A∕cm(2) at a few kV. However, if a small normal conducting solenoid is placed over the vacuum tube in position of the gun, a field of 0.1 T may be obtained. With this the use of LaB(6) as cathode material results in a magnetic compression of 44 and therewith in a focused current density in the trap region of more than 2000 A∕cm(2). By reversing the current in the gun solenoid the cathode field can easily compensated to zero. By proper design of the electrodes and the compression region, the gun will be able to deliver a beam in Brillouin flow. While this is interesting by itself--remember the "super-compression" reported on CRYEBIS-I--any magnetic field between zero and the value for immersed flow will result in an electron beam with a wide range of adjustable high current densities. The design tools used have been INTMAG(C) for the calculation of magnetic fields, EGN2(C) for the simulation of the gun and ANALYSE(C) for detailed analysis of the results (for more information see www.egun-igun.com).

  10. Application of electron beam equipment based on a plasma cathode gun in additive technology

    Science.gov (United States)

    Galchenko, N. K.; Kolesnikova, K. A.; Semenov, G. V.; Rau, A. G.; Raskoshniy, S. Y.; Bezzubko, A. V.; Dampilon, B. V.; Sorokova, S. N.

    2016-11-01

    The paper discusses the application of electron beam equipment based on a plasma cathode gun for three-dimensional surface modification of metals and alloys. The effect of substrate surface preparation on the adhesion strength of gas thermal coatings has been investigated.

  11. A device for determination of the electrical potential of a rocket carrying an electron gun

    International Nuclear Information System (INIS)

    Gringauz, K.I.; Musatov, L.S.; Shutte, N.M.; Beliashin, A.P.; Denstchikova, L.I.; Kopilov, V.F.

    1978-01-01

    Data on the principle of operation, sensors and electronics of a device for determination of the electrical potential relative to the surrounding medium of a rocket carrying an electric gun are presented. The device operated successfully on board an Eridan rocket during the ARAKS experiment. (Auth.)

  12. An inverted-geometry, high voltage polarized electron gun with UHV load lock

    International Nuclear Information System (INIS)

    Breidenbach, M.; Foss, M.; Hodgson, J.; Kulikov, A.; Odian, A.; Putallaz, G.; Rogers, H.; Schindler, R.; Skarpaas, K.; Zolotorev, M.

    1994-01-01

    The design of a high voltage electron source with a GaAs photocathode and a load lock system is described. The inverted high voltage structure of the gun permits a compact and simple design. Test results demonstrate that the load lock system provides a reliable way to achieve high quantum efficiency of the photocathode in a high voltage device. ((orig.))

  13. Ignition Features of Plasma-Beam Discharge in Gas-Discharge Electron Gun Operation

    Directory of Open Access Journals (Sweden)

    Valery A. Tutyk

    2013-01-01

    Full Text Available The current paper presents the results of experimental researches to determine the mode features of plasma-beam discharge (PBD generation by an electron beam injected by a low-vacuum gasdischarge electron gun (LGEG with the cold cathode and hollow anode on the basis of the high-voltage glow discharge and in the range of helium pressure of P ? 10 ÷ 130 Pa. The PBD boundaries and their dependences on parameters of an electron beam are found. The influence of PBD on parameters of low-vacuum gas-discharge electron gun is revealed. It causes an avalanche increase of electron beam current and burning of plasma-beam discharge in the whole space of the vacuum chamber volume and generation of electromagnetic radiation is revealed. Achieved results will be used for implementation of various vacuum technologies in the medium of reaction gas and generated electromagnetic radiation.

  14. RF study and 3-D simulations of a side-coupling thermionic RF-gun

    International Nuclear Information System (INIS)

    Rimjaem, S.; Kusoljariyakul, K.; Thongbai, C.

    2014-01-01

    A thermionic RF-gun for generating ultra-short electron bunches was optimized, developed and used as a source at a linac-based THz radiation research laboratory of the Plasma and Beam Physics Research Facility, Chiang Mai University, Thailand. The RF-gun is a π/2-mode standing wave structure, which consists of two S-band accelerating cells and a side-coupling cavity. The 2856 MHz RF wave is supplied from an S-band klystron to the gun through the waveguide input-port at the cylindrical wall of the second cell. A fraction of the RF power is coupled from the second cell to the first one via a side-coupling cavity. Both the waveguide input-port and the side-coupling cavity lead to an asymmetric geometry of the gun. RF properties and electromagnetic field distributions inside the RF-gun were studied and numerically simulated by using computer codes SUPERFISH 7.19 and CST Microwave Studio 2012 © . RF characterizations and tunings of the RF-gun were performed to ensure the reliability of the gun operation. The results from 3D simulations and measurements are compared and discussed in this paper. The influence of asymmetric field distributions inside the RF-gun on the electron beam properties was investigated via 3D beam dynamics simulations. A change in the coupling-plane of the side-coupling cavity is suggested to improve the gun performance

  15. RF study and 3-D simulations of a side-coupling thermionic RF-gun

    Energy Technology Data Exchange (ETDEWEB)

    Rimjaem, S., E-mail: sakhorn.rimjaem@cmu.ac.th [Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Thailand Center of Excellence in Physics (ThEP), Commission on Higher Education, Bangkok 10400 (Thailand); Kusoljariyakul, K.; Thongbai, C. [Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Thailand Center of Excellence in Physics (ThEP), Commission on Higher Education, Bangkok 10400 (Thailand)

    2014-02-01

    A thermionic RF-gun for generating ultra-short electron bunches was optimized, developed and used as a source at a linac-based THz radiation research laboratory of the Plasma and Beam Physics Research Facility, Chiang Mai University, Thailand. The RF-gun is a π/2-mode standing wave structure, which consists of two S-band accelerating cells and a side-coupling cavity. The 2856 MHz RF wave is supplied from an S-band klystron to the gun through the waveguide input-port at the cylindrical wall of the second cell. A fraction of the RF power is coupled from the second cell to the first one via a side-coupling cavity. Both the waveguide input-port and the side-coupling cavity lead to an asymmetric geometry of the gun. RF properties and electromagnetic field distributions inside the RF-gun were studied and numerically simulated by using computer codes SUPERFISH 7.19 and CST Microwave Studio 2012{sup ©}. RF characterizations and tunings of the RF-gun were performed to ensure the reliability of the gun operation. The results from 3D simulations and measurements are compared and discussed in this paper. The influence of asymmetric field distributions inside the RF-gun on the electron beam properties was investigated via 3D beam dynamics simulations. A change in the coupling-plane of the side-coupling cavity is suggested to improve the gun performance.

  16. RF study and 3-D simulations of a side-coupling thermionic RF-gun

    Science.gov (United States)

    Rimjaem, S.; Kusoljariyakul, K.; Thongbai, C.

    2014-02-01

    A thermionic RF-gun for generating ultra-short electron bunches was optimized, developed and used as a source at a linac-based THz radiation research laboratory of the Plasma and Beam Physics Research Facility, Chiang Mai University, Thailand. The RF-gun is a π/2-mode standing wave structure, which consists of two S-band accelerating cells and a side-coupling cavity. The 2856 MHz RF wave is supplied from an S-band klystron to the gun through the waveguide input-port at the cylindrical wall of the second cell. A fraction of the RF power is coupled from the second cell to the first one via a side-coupling cavity. Both the waveguide input-port and the side-coupling cavity lead to an asymmetric geometry of the gun. RF properties and electromagnetic field distributions inside the RF-gun were studied and numerically simulated by using computer codes SUPERFISH 7.19 and CST Microwave Studio 2012©. RF characterizations and tunings of the RF-gun were performed to ensure the reliability of the gun operation. The results from 3D simulations and measurements are compared and discussed in this paper. The influence of asymmetric field distributions inside the RF-gun on the electron beam properties was investigated via 3D beam dynamics simulations. A change in the coupling-plane of the side-coupling cavity is suggested to improve the gun performance.

  17. An in-situ photocathode loading system for the SLC Polarized Electron Gun

    International Nuclear Information System (INIS)

    Kirby, R.E.; Collet, G.J.; Skarpaas, K.

    1992-12-01

    An ultra-high vacuum loadlock system capable of operating at high voltage has been added to the SLC Polarized Electron Gun. The unit incorporates facilities for heat cleaning, activating and measuring the quantum efficiency of photocathodes. A tray of up to four photocathodes can be exchanged without bringing the activation unit or gun up to atmosphere. Low voltage quantum efficiencies of 20% have been obtained for bulk GaAs at 633 nm and 6% for a 0.3 micron GaAs layer at 755 nm. Results for other cathodes as well as operational characteristics are discussed

  18. Efficient temporal shaping of electron distributions for high-brightness photoemission electron guns

    Directory of Open Access Journals (Sweden)

    Ivan V. Bazarov

    2008-04-01

    Full Text Available To achieve the lowest emittance electron bunches from photoemission electron guns, it is essential to limit the uncorrelated emittance growth due to space charge forces acting on the bunch in the vicinity of the photocathode through appropriate temporal shaping of the optical pulses illuminating the photocathode. We present measurements of the temporal profile of electron bunches from a bulk crystal GaAs photocathode illuminated with 520 nm wavelength pulses from a frequency-doubled Yb-fiber laser. A transverse deflecting rf cavity was used to make these measurements. The measured laser pulse temporal profile and the corresponding electron beam temporal profile have about 30 ps FWHM duration, with rise and fall times of a few ps. GaAs illuminated by 520 nm optical pulses is a prompt emitter within our measurement uncertainty of ∼1  ps rms. Combined with the low thermal emittance of negative electron affinity photocathodes, GaAs is a very suitable photocathode for high-brightness photoinjectors. We also report measurements of the photoemission response time for GaAsP, which show a strong dependence on the quantum efficiency of the photocathode.

  19. A 7MeV S-Band 2998MHz Variable Pulse Length Linear Accelerator System

    CERN Document Server

    Hernandez, Michael; Mishin, Andrey V; Saverskiy, Aleksandr J; Skowbo, Dave; Smith, Richard

    2005-01-01

    American Science and Engineering High Energy Systems Division (AS&E HESD) has designed and commissioned a variable pulse length 7 MeV electron accelerator system. The system is capable of delivering a 7 MeV electron beam with a pulse length of 10 nS FWHM and a peak current of 1 ampere. The system can also produce electron pulses with lengths of 20, 50, 100, 200, 400 nS and 3 uS FWHM with corresponding lower peak currents. The accelerator system consists of a gridded electron gun, focusing coil, an electrostatic deflector system, Helmholtz coils, a standing wave side coupled S-band linac, a 2.6 MW peak power magnetron, an RF circulator, a fast toroid, vacuum system and a PLC/PC control system. The system has been operated at repetition rates up to 250pps. The design, simulations and experimental results from the accelerator system are presented in this paper.

  20. Design and development of a ring cathode electron gun as an evaporation source

    Energy Technology Data Exchange (ETDEWEB)

    Poyner, G T [Craswell Scientific Ltd., Cheltenham (UK)

    1976-11-01

    The RG2 ring cathode gun is a simple application of electron beam heating. The gun described was developed to provide a relatively inexpensive source for evaporating a range of metals and oxides which were otherwise difficult or impossible to evaporate by conventional resistance heating. Following several stages of improvement the gun was progressively reduced in size and the 'optics', or focusing, improved so that in its existing state an area of approximately 2mm diameter is heated. It was decided to limit the accelerating voltage as far as possible to minimize the practical problems associated with its operation and also the manufacture of the power supply. As development proceeded it became apparent that the relatively low accelerating voltage chosen improved the flexibility of the gun. Two versions are manufactured, the first, equipped with a six position rotary hearth, and the second, utilising a single hearth, is intended to be used as one of a pair. The latter design was reduced in size even further in order to minimize the distance between two adjacent guns.

  1. The design and development of a ring cathode electron gun as an evaporation source

    International Nuclear Information System (INIS)

    Poyner, G.T.

    1976-01-01

    The RG2 ring cathode gun is a simple application of electron beam heating. The gun described was developed to provide a relatively inexpensive source for evaporating a range of metals and oxides which were otherwise difficult or impossible to evaporate by conventional resistance heating. Following several stages of improvement the gun was progressively reduced in size and the 'optics', or focusing, improved so that in its existing state an area of approximately 2mm diameter is heated. It was decided to limit the accelerating voltage as far as possible to minimize the practical problems associated with its operation and also the manufacture of the power supply. As development proceeded it became apparent that the relatively low accelerating voltage chosen improved the flexibility of the gun. Two versions are manufactured, the first, equipped with a six position rotary hearth, and the second, utilising a single hearth, is intended to be used as one of a pair. The latter design was reduced in size even further in order to minimize the distance between two adjacent guns. (author)

  2. Stability measurements of the electron gun for the KATRIN rear section

    Energy Technology Data Exchange (ETDEWEB)

    Ebenhoech, Sylvia [Karlsruhe Institute of Technology (KIT) (Germany). Institute for Technical Physics (ITEP), Tritium Laboratory Karlsruhe (TLK); Collaboration: KATRIN-Collaboration

    2016-07-01

    The aim of the KArlsruhe TRItium Neutrino (KATRIN) experiment is to determine the antineutrino mass with a sensitivity of 0.2 eV (90 % C.L.) by high-precision spectroscopy close to the tritium beta decay endpoint at 18.6 keV. To achieve the sensitivity aim both statistical and systematic uncertainties must be minimized. One contribution to the systematic error are uncertainties in the column density of the tritium source or in the source activity. In order to detect and monitor changes in the tritium source the Rear Section, which is integrated at the rear end of the KATRIN setup, is used. The Rear Section includes an angular selective electron gun (e-gun) based on the photoelectric effect. With the e-gun it will be possible e.g. to achieve a precise calibration of the column source density. To achieve the requirements on the e-gun a stable UV light source is essential to produce photoelectrons. The presentation focuses on the setup of the e-gun and intensity stability measurements of the UV light source setup.

  3. Design and implementation of a fs-resolved transmission electron microscope based on thermionic gun technology

    Energy Technology Data Exchange (ETDEWEB)

    Piazza, L., E-mail: luca.piazza@epfl.ch [Laboratory for Ultrafast Microscopy and Electron Scattering (LUMES), ICMP, Ecole Polytechnique Fédérale de Lausanne, CH-1015 Lausanne (Switzerland); Masiel, D.J. [Integrated Dynamic Electron Solutions, Inc., 455 Bolero Drive, Danville, CA 94526 (United States); LaGrange, T.; Reed, B.W. [Condensed Matter and Materials Division Physical and Life Sciences Directorate, Lawrence Livermore National Laboratory, P.O. Box 808, L-356, Livermore, CA 94550 (United States); Barwick, B. [Department of Physics, Trinity College, 300 Summit St., Hartford, CT 06106 (United States); Carbone, Fabrizio [Laboratory for Ultrafast Microscopy and Electron Scattering (LUMES), ICMP, Ecole Polytechnique Fédérale de Lausanne, CH-1015 Lausanne (Switzerland)

    2013-09-23

    Highlights: • We present the implementation of a femtosecond-resolved ultrafast TEM. • This is the first ultrafast TEM based on a thermionic gun geometry. • An additional condenser lens has been used to maximize the electron count. • We achieved a time resolution of about 300 fs and an energy resolution of 1 eV. - Abstract: In this paper, the design and implementation of a femtosecond-resolved ultrafast transmission electron microscope is presented, based on a thermionic gun geometry. Utilizing an additional magnetic lens between the electron acceleration and the nominal condenser lens system, a larger percentage of the electrons created at the cathode are delivered to the specimen without degrading temporal, spatial and energy resolution significantly, while at the same time maintaining the femtosecond temporal resolution. Using the photon-induced near field electron microscopy effect (PINEM) on silver nanowires the cross-correlation between the light and electron pulses was measured, showing the impact of the gun settings and initiating laser pulse duration on the electron bunch properties. Tuneable electron pulses between 300 fs and several ps can be obtained, and an overall energy resolution around 1 eV was achieved.

  4. Design of the electron gun for the INS-ES linac

    International Nuclear Information System (INIS)

    Hashimoto, Yoshinori; Takeda, Yasuhiro; Yoshida, Katsuhide

    1993-01-01

    We are preparing a new electron gun for the INS-ES linac. Two cathode-wehnelt assemblies using dispenser cathode Y-646E (EIMAC) have been designed with the computer simulation program EGUN by W.B. Herrmannsfeldt. The acceleration voltage and the peak beam current is 100 kV and 1.0 A, respectively, with a pulse width of 1.5 μsec. The different point of the guns is the angle of wehnelt to the beam axis; one is 67.5deg and the other is 90deg. Both guns have almost the same beam characteristics: The beam radius is 1.95 mm and the maximum beam spread is 2.8 mrad at 186 mm from the cathode. (author)

  5. A study of an electron gun controlled with a meshless grid for a linear accelerator

    International Nuclear Information System (INIS)

    Homma, Akira; Nakata, Katsuhide; Sawamura, Teruko; Narita, Masakuni

    1996-01-01

    An electron gun for a linear accelerator with a control grid of meshless electrode (meshless grid) is expected to overcome some disadvantages of beam quality using an ordinary mesh grid. A gun of this type was designed and its characteristics were numerically analyzed. The simulation program code Egn2 with a boundary setting routine POLYGON was used. The result indicated that the grid can control the beam launched from the cathode to the anode electrode. It also indicated the Ip-Vp and Ip-Vp characteristics which are different from an ordinary triode gun with a mesh-grid. The mutual conductance gm of 0.4[mS], the maximum average current of 1.6[A] and cut-off voltage -200[V] were obtained under a condition of 200[kV] acceleration voltage. (author)

  6. Amorphous NEA Silicon Photocathodes - A Robust RF Gun Electron Source. Final Report

    International Nuclear Information System (INIS)

    Mulhollan, Gregory A.

    2009-01-01

    Amorphous silicon (a-Si) has been shown to have great promise as a negative electron affinity visible wavelength photocathode suitable for radio frequency (RF) gun systems. The specific operating wavelength can be shifted by growing it as a germanium alloy (a-Si(1-x)Ge(x)) rather than as pure silicon. This class of photoemitters has been shown to possess a high degree of immunity to charged particle flux. Such particle flux can be a significant problem in the operation of other photocathodes in RF gun systems. Its emission characteristics in the form of current per unit area, or current density, and emission angle, or beam spread are well matched for use in RF guns. Photocathodes made of a-Si can be fabricated on a variety of substrates including those most commonly employed in RF gun systems. Such photocathodes can be made for operation in either transmission or reflection mode. By growing them utilizing radio frequency plasma enhanced chemical vapor deposition, the unit cost is quite low, the quality is high and it is straightforward to grow custom size substrates and full or limited regions to confine the electron emission to the desired area. Quality emitters have been fabricated on tantalum, molybdenum, tungsten, titanium, copper, stainless steel, float glass, borosilicate glass and gallium arsenide. In addition to performing well in dedicated test chambers, a-Si photocathodes have been shown to function well in self-contained vacuum tubes. In this employment, they are subjected to a strenuous environment. Successful operation in this configuration provides additional confidence in their application to high energy linac photoinjectors and potentially as part of reliable, low cost photocathode driven RF gun systems that could become ready replacements for the diode and triode guns used on medical accelerators. Their applications in stand-alone vacuum tubes is just beginning to be explored.

  7. Cold cathode electron guns in the LASL high power short-pulse CO2 laser program

    International Nuclear Information System (INIS)

    Singer, S.; Ladish, J.S.; Nutter, M.J.

    1975-01-01

    The Electron Beam Controlled Discharge CO 2 Laser is now firmly established as the only high power short pulse laser amplifier that has been demonstrated to have scaling capabilities to large apertures and energies much greater than 100 J. These devices require a beam of energetic electrons to control the gas discharge that produces the required population inversion. Until recently, the electron source was usually a thermionic emitter, even for rather large lasers, whose heater requirements dwarfed the pulsed energies associated with the transient operation of the laser. With the advent of reliable cold-cathode electron guns, the operation of these lasers has been greatly simplified. At LASL, there are four electron beam controlled laser systems which are in operation, under construction, or in design: the 1 kJ system, now operational; the 2.5 kJ system; the 10 kJ system; and the 100 kJ system. Only the first uses thermionic-emitter electron guns; the remainder use or will use cold cathode sources. The operation of the 200 x 35 cm 2 two sided cold cathode electron gun used in the 2.5 kJ laser system and to be used in the 10 kJ laser is described

  8. Communication: Effects of thermionic-gun parameters on operating modes in ultrafast electron microscopy

    Directory of Open Access Journals (Sweden)

    Erik Kieft

    2015-09-01

    Full Text Available Ultrafast electron microscopes with thermionic guns and LaB6 sources can be operated in both the nanosecond, single-shot and femtosecond, single-electron modes. This has been demonstrated with conventional Wehnelt electrodes and absent any applied bias. Here, by conducting simulations using the General Particle Tracer code, we define the electron-gun parameter space within which various modes may be optimized. The properties of interest include electron collection efficiency, temporal and energy spreads, and effects of laser-pulse duration incident on the LaB6 source. We find that collection efficiencies can reach 100% for all modes, despite there being no bias applied to the electrode.

  9. Thermal and mechanical study of a MIG-type electron gun for a 31 GHz, 100 k W gyrotron

    International Nuclear Information System (INIS)

    Patire Junior, H.; Barroso, J.J.

    1994-01-01

    A thermal and mechanical study of a MIG-type electron gun has been made to determine the temperature distribution in all the gun elements as a function of the input heater power. Appropriate materials were selected to minimize both the conduction and radiation thermal losses. The electron emitting surface operates at an average temperature of 1000 0 C with 374 W input power in the heating filament system. The purpose of the present study is to reduce the input heater power while keeping the required operating cathode temperature and to improve the gun design from a constructional point of view aiming at extending the capabilities of the electron gun. A thermal software has been used by considering the operation conditions taking into account external convection by forced air and thermal radiation transfer between the electrodes of the gun. (author). 5 refs, 4 figs, 1 tab

  10. Synthesis method for using in the design of an electron gun for gyrotion

    International Nuclear Information System (INIS)

    Silva, C.A.B.

    1987-09-01

    In this work a synthesis method is applied to the design of an electron gun for a 94GHz gyrotron. Using the synthesis method, it is found the shape of the electrodes compatible with the laminar flow which minimizes the action of space change on the electron velocity dispersion. A sistematic procedure is presented to fuid the parameters of the synthesis method which, in turn, are closely related to the characteristics of the aptoclechonic system. (author) [pt

  11. Study on discrete space charge effects in electron beams and guns

    International Nuclear Information System (INIS)

    Tang Tiantong

    1990-01-01

    The discrete space charge effects in electron beams are studied and a statistical dynamics equation of the ensemble of beam electrons is derived. An approximated analytical solution of this equation is given. This equation has been applied to beam crossover and field-emission and thermal-emission gun problems. The computer calculation results agree on the whole with those of Monte Carlo simulation and experimental data. (orig.)

  12. A cold cathode of a gas-discharge electron-ion gun

    International Nuclear Information System (INIS)

    1974-01-01

    A cold cathode of a gas-discharge electron-ion gun is constructed in order to continuously replace the eroded material by feeding a wire or a set of coaxial cylinders in the spot where the ions hit the cathode. In this way, the form of the cathode and the electric-field configuration is preserved which guarantees the conservation of a sharp narrow electron beam profile

  13. Development of a new electron gun pulser by using high-speed MOS-FET's

    International Nuclear Information System (INIS)

    Suzuki, Ryoichi; Mikado, Tomohisa; Ohgaki, Hideaki; Chiwaki, Mitsukuni; Yamada, Kawakatsu; Sei, Norihiro; Sugiyama, Suguru; Noguchi, Tsutomu; Yamazaki, Tetsuo

    1993-01-01

    A new pulser for a low-emittance electron gun of the ETL linac has been developed by using high-speed MOS-FET's. The pulser can produce pulses of variable pulse width (5 ns - 4 μs) and of variable pulse height. Furthermore, the pulser can be operated with burst mode (100 ns period, more than 20 cycles) for single bunch injection to electron storage rings. (author)

  14. Investigation on the optimal magnetic field of a cusp electron gun for a W-band gyro-TWA

    Science.gov (United States)

    Zhang, Liang; He, Wenlong; Donaldson, Craig R.; Cross, Adrian W.

    2018-05-01

    High efficiency and broadband operation of a gyrotron traveling wave amplifier (gyro-TWA) require a high-quality electron beam with low-velocity spreads. The beam velocity spreads are mainly due to the differences of the electric and magnetic fields that the electrons withstand the electron gun. This paper investigates the possibility to decouple the design of electron gun geometry and the magnet system while still achieving optimal results, through a case study of designing a cusp electron gun for a W-band gyro-TWA. A global multiple-objective optimization routing was used to optimize the electron gun geometry for different predefined magnetic field profiles individually. Their results were compared and the properties of the required magnetic field profile are summarized.

  15. Sensitivity of perveance to cathode placement in a low perveance electron gun

    International Nuclear Information System (INIS)

    Lampel, M.C.; Herrmannsfeld, W.B.; Rand, R.E.; Wang, D.Y.

    1985-01-01

    The SLAC Electron Trajectory Program (EGUN) has been used to simulate a low perveance electron gun which will produce an 800 mA space charge limited beam at 130 kV. The simulations indicate that axial displacements of the cathode by + or -0.5 mm from its nominal position can produce a factor of two variation in the perveance of the electron gun. This sensitivity is due to the boundary conditions of the electrostatic potential near the cathode. Movement of the cathode relative to a fixed focus electrode produces an enhanced variation of the electric field near the cathode surface over that which occurs when both cathode and electrode are moved together. The simulations are in agreement with experimental data

  16. Effect of density distribution of cathode emission on the flux character in a strong-current electron gun

    International Nuclear Information System (INIS)

    Matora, I.M.; Merkulov, L.A.

    1975-01-01

    The effect is considered of two kinds of a dependence of the emission density from the electric field voltage on the emitter surface of a strong-current electron gun (the Schottky law and the ''3/2'' law) upon the choice of a form for the meridional cross section of this emitter at the condition of electron flux laminarity. A calculation example is given for electron gun with close to laminar flow assuming the validity of the Schottky law. The results of calculation of varying the laminar flux character are given which appears when varying parameters of the gun at the voltage 500 kV and current 250 A

  17. Study of beam transverse properties of a thermionic electron gun for application to a compact THz free electron laser

    International Nuclear Information System (INIS)

    Hu, Tongning; Qin, Bin; Tan, Ping; Chen, Qushan; Yang, Lei; Pei, Yuanji; Li, Ji

    2014-01-01

    A novel thermionic electron gun adopted for use in a high power THz free electron laser (FEL) is proposed in this paper. By optimization of the structural and radiofrequency (RF) parameters, the physical design of the gun is performed using dynamic calculations. Velocity bunching is used to minimize the bunch's energy spread, and the dynamic calculation results indicate that high quality beams can be provided. The transverse properties of the beams generated by the gun are also analyzed. The novel RF focusing effects of the resonance cavity are investigated precisely and are used to establish emittance compensation, which enables the injector length to be reduced. In addition, the causes of the extrema of the beam radius and the normalized transverse emittance are analyzed and interpreted, respectively, and slice simulations are performed to illustrate how the RF focusing varies along the bunch length and to determine the effects of that variation on the emittance compensation. Finally, by observation of the variations of the beam properties in the drift tube behind the electron gun, prospective assembly scenarios for the complete THz-FEL injector are discussed, and a joint-debugging process for the injector is implemented

  18. Electron gun for a multiple beam klystron with magnetic compression of the electron beams

    Science.gov (United States)

    Ives, R. Lawrence; Tran, Hien T; Bui, Thuc; Attarian, Adam; Tallis, William; David, John; Forstall, Virginia; Andujar, Cynthia; Blach, Noah T; Brown, David B; Gadson, Sean E; Kiley, Erin M; Read, Michael

    2013-10-01

    A multi-beam electron gun provides a plurality N of cathode assemblies comprising a cathode, anode, and focus electrode, each cathode assembly having a local cathode axis and also a central cathode point defined by the intersection of the local cathode axis with the emitting surface of the cathode. Each cathode is arranged with its central point positioned in a plane orthogonal to a device central axis, with each cathode central point an equal distance from the device axis and with an included angle of 360/N between each cathode central point. The local axis of each cathode has a cathode divergence angle with respect to the central axis which is set such that the diverging magnetic field from a solenoidal coil is less than 5 degrees with respect to the projection of the local cathode axis onto a cathode reference plane formed by the device axis and the central cathode point, and the local axis of each cathode is also set such that the angle formed between the cathode reference plane and the local cathode axis results in minimum spiraling in the path of the electron beams in a homogenous magnetic field region of the solenoidal field generator.

  19. State-of-the-Art Electron Guns and Injector Designs for Energy Recovery Linacs (ERL)

    CERN Document Server

    Todd, Alan; Ben-Zvi, Ilan; Benson, Stephen V; Blüm, Hans; Burrill, Andrew; Calaga, Rama; Cameron, Peter; Campisi, Isidoro E; Chang, Xiangyun; Christina, Vincent; Cole, Michael; Colestock, Patrick L; Daly, Edward; Douglas, David; Dylla, Fred H; Falletta, Michael; Hahn, Harald; Hernandez-Garcia, Carlos; Hogan, John; Holmes, Douglas; Janssen, Dietmar; Kayran, Dmitry; Kelley, John P; Kewisch, Jorg; Kneisel, Peter; Kurennoy, Sergey; Lewellen, John W; Litvinenko, Vladimir N; Mammosser, John; McIntyre, Gary; Neil, George R; Nguyen, Dinh C; Nicoletti, Tony; Peterson, Ed; Phillips, Larry; Preble, Joseph P; Rank, Jim; Rao, Triveni; Rathke, John; Reass, William; Rees, Daniel; Rimmer, Robert; Rode, Claus; Russell, Steven; Scaduto, Joseph; Schrage, Dale L; Schultheiss, Tom; Sekutowicz, Jacek; Siggins, Tim; Warren Funk, L; Whitlach, Timothy; Wiseman, Mark; Wong, Robert; Wood, Richard L; Wu, Kuo-Chen; Young, Lloyd M; Zaltsman, Alex; Zhao, Yongxiang

    2005-01-01

    A key technology issue of ERL devices for high-power free-electron laser (FEL) and 4th generation light sources is the demonstration of reliable, high-brightness, high-power injector operation. Ongoing programs that target up to 1 Ampere injector performance at emittance values consistent with the requirements of these applications are described. We consider that there are three possible approaches that could deliver the required performance. The first is a DC photocathode gun and superconducting RF (SRF) booster cryomodule. Such a 750 MHz device is being integrated and will be tested up to 100 mA at the Thomas Jefferson National Accelerator Facility beginning in 2007. The second approach is a high-current normal-conducting RF photoinjector. A 700 MHz gun will undergo thermal test in 2006 at the Los Alamos National Laboratory, which, if successful, when equipped with a suitable cathode, would be capable of 1 Ampere operation. The last option is an SRF gun. A half-cell 703 MHz SRF gun capable of delivering 1.0...

  20. The Development of the Linac Coherent Light Source RF Gun

    International Nuclear Information System (INIS)

    Dowell, D

    2008-01-01

    The Linac Coherent Light Source (LCLS) is the first x-ray laser user facility based upon a free electron laser (FEL) requiring extraordinary beam quality to saturate at 1.5 angstroms within a 100 meter undulator.[1] This new type of light source is using the last kilometer of the three kilometer linac at SLAC to accelerate the beam to an energy as high as 13.6 GeV and required a new electron gun and injector to produce a very bright beam for acceleration. At the outset of the project it was recognized that existing RF guns had the potential to produce the desired beam but none had demonstrated it. Therefore a new RF gun or at least the modification of an existing gun was necessary. The parameters listed in Table 1 illustrate the unique characteristics of LCLS which drive the requirements for the electron gun as given in Table 2. The gun beam quality needs to accommodate emittance growth as the beam is travels through approximately one kilometer of linac and two bunch compressors before reaching the undulator. These beam requirements were demonstrated during the recent commissioning runs of the LCLS injector and linac [2] due to the successful design, fabrication, testing and operation of the LCLS gun. The goal of this paper is to relate the technical background of how the gun was able to achieve and in some cases exceed these requirements by understanding and correcting the deficiencies of the prototype s-band RF photocathode gun, the BNL/SLAC/UCLA Gun III. This paper begins with a brief history and technical description of Gun III and the Gun Test Facility (GTF) at SLAC, and studies of the gun's RF and emittance compensation solenoid. The work at the GTF identified the gun and solenoid deficiencies, and helped to define the specifications for the LCLS gun. Section 1.1.5 describes the modeling used to compute and correct the gun RF fields and Section 1.1.6 describes the use of these fields in the electron beam simulations. The magnetic design and measurements of

  1. S3 targets monitoring with an electron gun

    Science.gov (United States)

    Kallunkathariyil, J.; Stodel, Ch.; Marry, C.; Frémont, G.; Bastin, B.; Piot, J.; Clément, E.; Le Moal, S.; Morel, V.; Thomas, J.-C.; Kamalou, O.; Spitaëls, C.; Savajols, H.; Vostinar, M.; Pellemoine, F.; Mittig, W.

    2018-05-01

    The monitoring of targets under irradiation was investigated using a 20 keV electron beam. An integrated and automated electron beam deflection was developed allowing a monitoring over the whole surface of target materials. Thus, local defects could be identified on-line during an experiment performed at GANIL involving different materials irradiated with a focused krypton beam at 10.5 MeV/u. Performances of this target monitoring system are presented in this paper.

  2. Theory And Design Of Thermionic Electron Beam Guns

    International Nuclear Information System (INIS)

    Iqbal, Munawar; Fazal-e-Aleem

    2005-01-01

    Electron beam technology has a long history and wide applications in various fields including high-energy physics. The unique properties, which one can develop by using different configurations, have been one of the strongest driving forces for this multi-dimensional technology. In this paper, we will take up the subject along with applications in various areas of physics. We will particularly focus on the developments of electron beam sources by our laboratory

  3. Design and construction of a DC high-brightness laser driven electron gun

    Science.gov (United States)

    Zhao, K.; Geng, R. L.; Wang, L. F.; Zhang, B. C.; Yu, J.; Wang, T.; Wu, G. F.; Song, J. H.; Chen, J. E.

    1996-02-01

    A DC high-brightness laser driven photoemissive electron gun is being developed at Peking University, in order to produce 50-100 ps electron bunches of high quality. The gun consists of a photocathode preparation chamber and a DC acceleration cavity. Different ways of fabricating photocathodes, such as chemical vapor deposition, ion beam implantation and ion beam enhanced deposition, can be adopted. The acceleration gap is designed with the aid of simulation codes EGUN and POISSON. The laser system is a mode-locked Nd-YAG oscillator proceeded by an amplifier at 10 Hz repetition rate, which can deliver three different wavelengths (1064/532/266 nm). The combination of a superconducting cavity with the photocathode preparation chamber is also discussed in this paper.

  4. Low-cost electron-gun pulser for table-top maser experiments

    Science.gov (United States)

    Grinberg, V.; Jerby, E.; Shahadi, A.

    1995-04-01

    A simple 10 kV electron-gun pulser for small-scale maser experiments is presented. This low-cost pulser has operated successfully in various table-top cyclotron-resonance maser (CRM) and free-electron maser (FEM) experiments. It consists of a low-voltage capacitor bank, an SCR control circuit and a transformer bank (car ignition coils) connected directly to the e-gun. The pulser produces a current of 3 A at 10 kV voltage in a Gaussian like shape of 1 ms pulse width. The voltage sweep during the pulse provides a useful tool to locate resonances of CRM and FEM interactions. Analytical expressions for the pulser design and experimental measurements are presented.

  5. Systematic study of a simple formation of pierce-electron-gun

    International Nuclear Information System (INIS)

    Saad, Hussein Mahmoud; Abd Elhamed, H.

    1985-01-01

    In this work the design and construction of a simple form of Pierce Gun are discussed. As the vacuum system used in the experiment was frequently exposed to open air, a solenoid filamentary-cathode was used. Hence, an effective magnetic field has been induced as the filament was heated, whereupon the electrons altered their paths. We, therefore investigated the change in beam intensity as influenced by the focusing electrode material, anode position, and extraction hole width. The focusing electrode effect was examined by comparing the measured emission current density with the corresponding calculated value. The studies showed that electrons follow a saddle-like shape in the gun inter-space. It was modified by the stainless steel focusing electrode

  6. A high-compression electron gun for C6+ production: concept, simulations and mechanical design

    Science.gov (United States)

    Mertzig, Robert; Breitenfeldt, M.; Mathot, S.; Pitters, J.; Shornikov, A.; Wenander, F.

    2017-07-01

    In this paper we report on simulations and the mechanical design of a high-compression electron gun for an Electron Beam Ion Source (EBIS) dedicated for production of high intensity and high repetition rate pulses of bare carbon ions for injection into linac-based hadron therapy facilities. The gun is presently under construction at CERN to be retrofitted into the TwinEBIS test bench for experimental studies. We describe the design constraints, show results of numeric simulations and report on the mechanical design featuring several novel ideas. The reported design makes use of combined-function units with reduced number of mechanical joints that were carefully controlled and tuned during the manufacturing phase. The simulations addressed a wide range of topics including the influence of thermal effects, focusing optics, symmetry-breaking misalignments and injection into a full 5 T field.

  7. Solid-state pulse modulator using Marx generator for a medical linac electron-gun

    Science.gov (United States)

    Lim, Heuijin; Hyeok Jeong, Dong; Lee, Manwoo; Lee, Mujin; Yi, Jungyu; Yang, Kwangmo; Ro, Sung Chae

    2016-04-01

    A medical linac is used for the cancer treatment and consists of an accelerating column, waveguide components, a magnetron, an electron-gun, a pulse modulator, and an irradiation system. The pulse modulator based on hydrogen thyratron-switched pulse-forming network is commonly used in linac. As the improvement of the high power semiconductors in switching speed, voltage rating, and current rating, an insulated gate bipolar transistor has become the more popular device used for pulsed power systems. We propose a solid-state pulse modulator to generator high voltage by multi-stacked storage-switch stages based on the Marx generator. The advantage of our modulator comes from the use of two semiconductors to control charging and discharging of the storage capacitor at each stage and it allows to generate the pulse with various amplitudes, widths, and shapes. In addition, a gate driver for two semiconductors is designed to reduce the control channels and to protect the circuits. It is developed for providing the pulsed power to a medical linac electron-gun that requires 25 kV and 1 A as the first application. In order to improve the power efficiency and achieve the compactness modulator, a capacitor charging power supply, a Marx pulse generator, and an electron-gun heater isolated transformer are constructed and integrated. This technology is also being developed to extend the high power pulsed system with > 1 MW and also other applications such as a plasma immersed ion implantation and a micro pulse electrostatic precipitator which especially require variable pulse shape and high repetition rate > 1 kHz. The paper describes the design features and the construction of this solid-state pulse modulator. Also shown are the performance results into the linac electron-gun.

  8. Investigating the effect of electron emission pattern on RF gun beam quality

    Energy Technology Data Exchange (ETDEWEB)

    Rajabi, A. [Laser and Plasma Research Institute, Shahid Beheshti University, G.C., Velenjak, 1983963113, Tehran (Iran, Islamic Republic of); Shokri, B., E-mail: b-shokri@sbu.ac.ir [Laser and Plasma Research Institute, Shahid Beheshti University, G.C., Velenjak, 1983963113, Tehran (Iran, Islamic Republic of); Physics Department, Shahid Beheshti University, G.C., Velenjak, 1983963113, Tehran (Iran, Islamic Republic of)

    2016-05-11

    Thermionic radio frequency gun is one of the most promising choices to gain a high quality electron beam, used in the infrared free electron lasers and synchrotron radiation injectors. To study the quality of the beam in a compact electron source, the emission pattern effect on the beam dynamics should be investigated. In the presented work, we developed a 3D simulation code to model the real process of thermionic emission and to investigate the effect of emission pattern, by considering geometrical constraints, on the beam dynamics. According to the results, the electron bunch emittance varies considerably with the emission pattern. Simulation results have been validated via comparison with the well-known simulation codes such as ASTRA simulation code and CST microwave studio, as well as other simulation results in the literature. It was also demonstrated that by using a continuous wave laser beam for heating the cathode, the emission pattern full width at half maximum (FWHM) of the transverse emission distribution is proportional to FWHM of the Gaussian profile for the laser beam. Additionally, by using the developed code, the effect of wall structure around the cathode on the back bombardment effect has been studied. According to the results, for a stable operation of the RF gun, one should consider the nose cone in vicinity of the cathode surface to reduce the back-bombardment effect. - Highlights: • We developed a 3D code to simulate the beam dynamics of thermionic RF gun. • Te impact of the emission pattern on the beam dynamic was investigated. • Different emission pattern results different emittance in the gun exit. • Using a nosecone around the cathode adjacent wall reduces back bombardment effect.

  9. Solid-state pulse modulator using Marx generator for a medical linac electron-gun

    International Nuclear Information System (INIS)

    Lim, Heuijin; Jeong, Dong Hyeok; Lee, Manwoo; Lee, Mujin; Yi, Jungyu; Yang, Kwangmo; Ro, Sung Chae

    2016-01-01

    A medical linac is used for the cancer treatment and consists of an accelerating column, waveguide components, a magnetron, an electron-gun, a pulse modulator, and an irradiation system. The pulse modulator based on hydrogen thyratron-switched pulse-forming network is commonly used in linac. As the improvement of the high power semiconductors in switching speed, voltage rating, and current rating, an insulated gate bipolar transistor has become the more popular device used for pulsed power systems. We propose a solid-state pulse modulator to generator high voltage by multi-stacked storage-switch stages based on the Marx generator. The advantage of our modulator comes from the use of two semiconductors to control charging and discharging of the storage capacitor at each stage and it allows to generate the pulse with various amplitudes, widths, and shapes. In addition, a gate driver for two semiconductors is designed to reduce the control channels and to protect the circuits. It is developed for providing the pulsed power to a medical linac electron-gun that requires 25 kV and 1 A as the first application. In order to improve the power efficiency and achieve the compactness modulator, a capacitor charging power supply, a Marx pulse generator, and an electron-gun heater isolated transformer are constructed and integrated. This technology is also being developed to extend the high power pulsed system with > 1 MW and also other applications such as a plasma immersed ion implantation and a micro pulse electrostatic precipitator which especially require variable pulse shape and high repetition rate > 1 kHz. The paper describes the design features and the construction of this solid-state pulse modulator. Also shown are the performance results into the linac electron-gun

  10. A high peak power S-band switching system for the Advanced Photon Source (APS) Linear Accelerator (Linac)

    International Nuclear Information System (INIS)

    Grelick, A. E.

    1998-01-01

    An S-band linear accelerator is the source of particles and front end of the Advanced Photon Source [1] injector. Additionally, it will be used to support a low-energy undulator test line (LEUTL) and to drive a free-electron laser (FEL). To provide maximum linac availability for all uses, an additional modulator-klystron subsystem has been built,and a waveguide-switching and distribution subsystem is now under construction. The combined subsystems provide a hot spare for any of the five S-band transmitters that power the lina cand have been given the additional function of powering an rf gun test stand whenever they are not otherwise needed. Design considerations for the waveguide-switching subsystem, topology selection, timing, control, and system protection provisions are described

  11. Design of planar electron gun for UHF range, CW power inductive output tube

    International Nuclear Information System (INIS)

    Kaushik, Meenu; Joshi, L.M.

    2015-01-01

    Inductive Output Tube (lOT) is an amplifier which is now-a-days in demand for scientific applications. For every vacuum tube, electron gun is an important part and in fact considered as the heart of the tube. Hence, designing of this component is very crucial for efficient operation of the device throughout its lifetime. This paper is all about the electromagnetic (EM) design of planar electron gun of 40 kV, 3.5 A beam voltage and beam current respectively, for a 100 kW CW power lOT operating in UHF range. The design considerations and basic equations involved in its design are included in the paper. The gun structure has been optimized for getting the desired beam characteristics. The simulation results including the beam profile along with the beam current are shown using two commercial codes namely TRAK and MAGIC code. Planar shape of electron beam reduces space charge forces in the beam itself and consequently beam energy spread for a given current. The magnetic focusing of planar beam is easier comparative to spherical beam hence, this structure has been adopted for this particular device design. (author)

  12. A numerical study of emittance growths in RF guns

    CERN Document Server

    Masuda, K; Sobajima, M; Kitagaki, J; Ohnishi, M; Toku, H; Yoshikawa, K

    1999-01-01

    A beam with greatly reduced emittance is required for further improvements of FELs, in particular, for FELs of shorter wavelengths, and of narrower bandwidths. From this viewpoint, the BNL/SLAC/UCLA 1.6-cell S-band photocathode RF gun performance characteristics were calculated, first in order to evaluate what may contribute to the emittance growths in photocathode RF guns. We developed an RF gun to produce an electron beam with an extremely low emittance, by using a 2-D simulation code. It is found that, by optimizing the laser injection phase, the drive laser spot radius and the cavity shape around the laser spot, the beam emittance by the 1.6-cell RF gun can be greatly reduced to 2.1 pi mm mrad, from the previous 4.4 pi mm mrad of the original shape.

  13. Isolated grid electron gun and pulser system for long/short pulse operation

    International Nuclear Information System (INIS)

    Koontz, R.F.; Feathers, L.; Kilbourne, C.; Leger, G.; McKinney, T.

    1984-04-01

    The new NPI gun at SLAC serves the dual functions of producing long pulse (up to 5 μsec, 180 pps) electron bursts for nuclear physics experiments, and also short (1 nsec) pulses for filling Stanford Synchrotron Radiation Laboratory (SSRL). This is accomplished by means of a newly designed, isolated grid gun, cathode pulsed with a solid state long pulse pulser, and grid pulsed with a fast recharging avalanche type short pulse (1 nsec) grid pulser. The grid pulser is bipolar so that a fast blackout notch can be placed in the long cathode pulse. This fast notch can be seen by Stanford Linear Collider (SLC) instrumentation and allows the long pulse beam to be computer controlled by SLC intensity and beam position monitors

  14. An isolated grid electron gun and pulser system for long/short pulse operation

    International Nuclear Information System (INIS)

    Koontz, R.F.; Feathers, L.; Kilbourne, C.; Leger, G.; McKinney, T.

    1984-01-01

    The new NPI gun at SLAC serves the dual functions of producing long pulse (up to 5 μsec, 180 pps) electron bursts for nuclear physics experiments, and also short ( 1 nsec) pulses for filling Stanford Synchrotron Radiation Laboratory (SSRL). This is accomplished by means of a newly designed, isolated grid gun, cathode pulsed with a solid state long pulse pulser, and grid pulsed with a fast recharging avalanche type short pulse (1 nsec) grid pulser. The grid pulser is bipolar so that a fast blackout notch can be placed in the long cathode pulse. This fast notch can be seen by Stanford Linear Collider (SLC) instrumentation and allows the long pulse beam to be computer controlled by SLC intensity and beam position monitors. (orig.)

  15. Enhancement of ECR performances by means of carbon nano-tubes based electron guns

    International Nuclear Information System (INIS)

    Odorici, F.; Cuffiani, M.; Malferrari, L.; Rizzoli, R.; Veronese, G.P.; Celona, L.; Gammino, S.; Mascali, D.; Miracoli, R.; Romano, F.P.; Gambino, N.; Castro, G.; Ciavola, G.; Serafino, T.

    2012-01-01

    The CANTES experiment at INFN-LNS tested the use of carbon nano-tubes (CNTs) to emit electrons by field emission effect, in order to provide additional electrons to the plasma core of an ECR ion source. This technique was used with the Caesar source, demonstrating that the total extracted ion current is increased and that a relevant reduction of the number of 'high energy' electrons (above 100 keV) may be observed. The injection of additional electrons inside the plasma increases the amount of cold and warm electrons, and then the number of ionizing collisions. Details of the construction of CNTs based electron gun and of the improvement of performances of the Caesar ECR ion source will be presented. The paper is followed by the associated poster. (authors)

  16. High-brightness electron guns for linac-based light sources

    International Nuclear Information System (INIS)

    Lewellen, J.W.

    2004-01-01

    Most proposed linac-based light sources, such as single-pass free-electron lasers and energy-recovery-linacs, require very high-brightness electron beams in order to achieve their design performance. These beam requirements must be achieved not on an occasional basis, but rather must be met by every bunch produced by the source over extended periods of time. It is widely assumed that the beam source will be a photocathode electron gun; the selection of accelerator technique (e.g., dc or rf) for the gun is more dependent on the application.The current state of the art of electron beam production is adequate but not ideal for the first generation of linac-based light sources, such as the Linac Coherent Light Source (LCLS) x-ray free-electron laser (X-FEL). For the next generation of linac-based light sources, an order of magnitude reduction in the transverse electron beam emittance is required to significantly reduce the cost of the facility. This is beyond the present state of the art, given the other beam properties that must be maintained. The requirements for current and future linac-based light source beam sources are presented here, along with a review of the present state of the art. A discussion of potential paths towards meeting future needs is presented at the conclusion.

  17. Characteristics of a wire ion plasma source and a secondary emission electron gun

    International Nuclear Information System (INIS)

    Hotta, Eiki; Osawa, Teruya; Urai, Hajime; Suzuki, Mitsuaki; Yasui, Hiroyuki; Tamagawa, Tohru

    1993-01-01

    Electrical characteristics of a wire ion plasma source (WIPS) and a secondary emission electron gun, for which the WIPS is used as an ion source, will be reported. The WIPS is a cold-cathode gaseous discharge device, in which a radial electron trapping permits an extremely low pressure gaseous discharge with very low applied voltages. The time evolutions of temperature and density of afterglow plasma were measured with a double probe. In the case of P 0 = 25 mTorr He and the maximum discharge current of 200 A, the temperature and density of electron were about 20 eV and of the order of 10 18 m -3 , respectively, just after the distinction of discharge. The ion current density measured by a biased ion collector (BIC) on the discharge tube wall was found to reach up to 300 mA/cm 2 . A secondary emission electron gun was set on the discharge tube wall opposite to the BIC. An earthed mesh net is installed at a height of 8 mm just in front of the cathode. The maximum negative bias voltage applied to the cathode is limited to -50 kV by the local breakdown in the gun, which occurred synchronously with the WIPS discharge. The electron beam current was measured by the BIC, in which an aluminum foil with a width of 2 μm was placed on instead of the earthed mesh net. At the cathode voltage of -30 kV, the measured beam current density was 220 mA/cm 2 . The extraporation of the resulted curve indicates that if the cathode voltage is -100 kV, the current density will reach to 1 A/cm 2 . The energy spectrum of the electron beam was measured with a magnetic energy analyzer, which was set in place of the BIC. The energy spread is about 300 eV at the central energy of 40 keV. Thus, they demonstrated the possibility of a high current density secondary emission electron gun, for which a WIPS is used as an ion source

  18. EGUN: An electron optics and gun design program

    International Nuclear Information System (INIS)

    Herrmannsfeldt, W.B.

    1988-10-01

    The name EGUN has become commonly associated with the program also known as the SLAC Electron Trajectory Program. This document is an updated version of SLAC-226, published in 1979. The program itself has had substantial upgrading since then, but only a few new features are of much concern to the user. Most of the improvements are internal and are intended to improve speed or accuracy. EGUN is designed to compute trajectories of charged particles in electrostatic and magnetostatic fields, including the effects of space charge and self-magnetic fields. Starting options include Child's Law conditions on cathodes of various shapes, as well as used specified initial conditions. Either rectangular or cylindrical symmetry may be used. In the new jargon, the program is a 2-1/2 dimension code meaning 2-D in all fields and 3-D in all particle motion. A Poisson's Equation Solver is used to find the electrostatic fields by using difference equations derived from the boundary conditions. Magnetic fields are to be specified externally, by the user, by using one of several methods including data from another program or arbitrary configurations of coils. This edition of the documentation also covers the program EGN87c, which is a recently developed version of EGUN designed to be used on the newer models of personal computers, small main frames, work stations, etc. The EGN87c program uses the programming language C which is very transportable so the program should operate on any system that supports C. Plotting routines for most common PC monitors are included, and the capability to make hard copy plots on dot-matrix printer-plotters is provided. 18 refs., 7 figs

  19. Time-dependent plasma behavior triggered by a pulsed electron gun under conditions of beam-plasma-discharge

    International Nuclear Information System (INIS)

    Szuszczewicz, E.P.; Lin, C.S.

    1982-01-01

    This chapter reports on experiments whose purpose was to simulate spaceborne applications of energetic electron guns while exploring the ''in situ'' diagnostics of time-dependent beam-plasma behavior under pulsed electron gun conditions. Beam-plasma-discharge (BPD), the BPD afterglow that exists after gun-pulse termination, and the plasma decay process are considered. It is concluded that there is a rapid enhancement in plasma density as the gas turns on; that during the pulse-ON time a quasi-steady-state BPD can be maintained with characteristics identical with its dc counterpart; that in the period immediately following gun-pulse termination the plasma loss process is dominated by cross-field radial diffusion; and that the afterglow plasma is within + or -10% of being an isodensity contour

  20. CeB6 electron gun for the soft X-ray FEL project at SPring-8

    International Nuclear Information System (INIS)

    Togawa, K.; Baba, H.; Onoe, K.; Inagaki, T.; Shintake, T.; Matsumoto, H.

    2004-01-01

    A pulsed high-voltage electron gun with a thermionic cathode is under development for the injector system of the soft X-ray FEL project at SPring-8 (SCSS project). A CeB 6 single crystal of 3 mm diameter was chosen as a thermionic cathode because of its excellent emission properties, i.e., high resistance against contamination, uniform emission density and smooth surface. The CeB 6 cathode can produce a 3 A beam with 2 μs FWHM. A gun voltage of -500 kV was chosen as a compromise between the need for controlling emittance growth and minimizing the risks of high-voltage arcing. We have constructed a 500 kV electron gun test stand and have begun performance tests. This paper describes the basic design and the current status of the hardware R and D on the CeB 6 gun

  1. Design of a pulsed angular selective electron gun for the KATRIN main spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Winzen, Daniel; Hannen, Volker; Ortjohann, Hans-Werner; Zacher, Michael; Weinheimer, Christian [Institut fuer Kernphysik, Westfaelische Wilhelms-Universitaet, Muenster (Germany); Collaboration: KATRIN-Collaboration

    2012-07-01

    The KATRIN (KArlsruhe TRItium Neutrino mass) experiment will study the tritium {beta}-spectrum near the endpoint of 18.6 keV, aiming to measure the mass of the electron antineutrino. Using an electrostatic retarding spectrometer (MAC-E-Filter), the projected sensitivity for m{sub ve} is 200 meV/c{sup 2} at 90% C.L. In order to map out the electric and magnetic fields in the main spectrometer, an angular selective electron gun is currently being developed. The e-gun uses an UV-Laser to produce electrons via the photo-electric effect from a copper substrate which are then accelerated electrostatically. It features a small energy spread of approx. 0.1 eV, a sharp emission angle and will be able to cover the whole magnetic flux tube of KATRIN. Using a pulsed laser it is also possible to investigate the time of flight (TOF) of electrons through the spectrometer, offering enhanced sensitivity to spectrometer properties far away from the analysing plane. By comparing information from transmission function measurements and TOF data with Monte Carlo simulations of the setup, one will be able to achieve a detailed understanding of the spectrometer properties.

  2. Adaptive electron beam shaping using a photoemission gun and spatial light modulator

    Science.gov (United States)

    Maxson, Jared; Lee, Hyeri; Bartnik, Adam C.; Kiefer, Jacob; Bazarov, Ivan

    2015-02-01

    The need for precisely defined beam shapes in photoelectron sources has been well established. In this paper, we use a spatial light modulator and simple shaping algorithm to create arbitrary, detailed transverse laser shapes with high fidelity. We transmit this shaped laser to the photocathode of a high voltage dc gun. Using beam currents where space charge is negligible, and using an imaging solenoid and fluorescent viewscreen, we show that the resultant beam shape preserves these detailed features with similar fidelity. Next, instead of transmitting a shaped laser profile, we use an active feedback on the unshaped electron beam image to create equally accurate and detailed shapes. We demonstrate that this electron beam feedback has the added advantage of correcting for electron optical aberrations, yielding shapes without skew. The method may serve to provide precisely defined electron beams for low current target experiments, space-charge dominated beam commissioning, as well as for online adaptive correction of photocathode quantum efficiency degradation.

  3. The Use of a Solid State Analog Television Transmitter as a Superconducting Electron Gun Power Amplifier

    Energy Technology Data Exchange (ETDEWEB)

    J.G. Kulpin, K.J. Kleman, R.A. Legg

    2012-07-01

    A solid state analog television transmitter designed for 200 MHz operation is being commissioned as a radio frequency power amplifier on the Wisconsin superconducting electron gun cavity. The amplifier consists of three separate radio frequency power combiner cabinets and one monitor and control cabinet. The transmitter employs rugged field effect transistors built into one kilowatt drawers that are individually hot swappable at maximum continuous power output. The total combined power of the transmitter system is 33 kW at 200 MHz, output through a standard coaxial transmission line. A low level radio frequency system is employed to digitally synthesize the 200 MHz signal and precisely control amplitude and phase.

  4. Novel radio-frequency gun structures for ultrafast relativistic electron diffraction.

    Science.gov (United States)

    Musumeci, P; Faillace, L; Fukasawa, A; Moody, J T; O'Shea, B; Rosenzweig, J B; Scoby, C M

    2009-08-01

    Radio-frequency (RF) photoinjector-based relativistic ultrafast electron diffraction (UED) is a promising new technique that has the potential to probe structural changes at the atomic scale with sub-100 fs temporal resolution in a single shot. We analyze the limitations on the temporal and spatial resolution of this technique considering the operating parameters of a standard 1.6 cell RF gun (which is the RF photoinjector used for the first experimental tests of relativistic UED at Stanford Linear Accelerator Center; University of California, Los Angeles; Brookhaven National Laboratory), and study the possibility of employing novel RF structures to circumvent some of these limits.

  5. The electron gun for high power high HV accelerator; Wyrzutnia elektronow do akceleratora wysokiego napiecia duzej mocy

    Energy Technology Data Exchange (ETDEWEB)

    Drabik, W.; Kielsznia, R.; Kapla, P.; Stras, W. [Soltan Inst. for Nuclear Studies, Otwock-Swierk (Poland)

    1994-12-31

    Application of electron accelerators, for purification of flue gases from SO{sub 2} and NO{sub x} in industrial mode requires electron accelerators with 200 - 300 kW power. The electron source in such accelerators has to generate the current 200 - 300 mA for long time. In this report the technical project of d.c. electron gun with parameters 250 mA, 5 kW is presented. The construction of the gun is described, it consist of cathode made of LaB{sub 6} and heater made of pyrolytic graphite. For investigation of gun characteristics the test stand was build and the result of parameters measurements are also presented. The good agreement between assumed and measured parameters has been obtained. (author). 13 refs, 20 figs.

  6. Effects of pulse-length and emitter area on virtual cathode formation in electron guns

    International Nuclear Information System (INIS)

    Valfells, Agust; Feldman, D.W.; Virgo, M.; O'Shea, P.G.; Lau, Y.Y.

    2002-01-01

    Recent experiments at the University of Maryland using photoemission from a dispenser cathode have yielded some interesting results regarding the effects of the area of emission and of the ratio between the pulse length and the gap transit time on the amount of current that may be drawn from an electron gun before a virtual cathode forms. The experiments show that a much higher current density may be drawn from a short pulse or limited emitter area than is anticipated by the Child-Langmuir limiting current. There is also evidence that the current may be increased even after virtual cathode formation, which leads a distinction between a limiting current density and a current density critical for virtual cathode formation. The experiments have also yielded some interesting results on the longitudinal structure of the current pulse passed through the anode. Some empirical and theoretical scaling laws regarding the formation of virtual cathodes in an electron gun will be presented. This work was motivated by the needs of the University of Maryland Electron Ring (UMER) [P. G. O'Shea, M. Reiser, R. A. Kishek et al., Nucl. Instrum. Methods Phys. Res. A 464, 646 (2001)] where the goal is to generate pulses that are well-localized in time and space

  7. Ion Back-Bombardment of GaAs Photocathodes Inside DC High Voltage Electron Guns

    CERN Document Server

    Grames, Joseph M; Brittian, Joshua; Charles, Daniel; Clark, Jim; Hansknecht, John; Lynn Stutzman, Marcy; Poelker, Matthew; Surles-Law, Kenneth E

    2005-01-01

    The primary limitation for sustained high quantum efficiency operation of GaAs photocathodes inside DC high voltage electron guns is ion back-bombardment of the photocathode. This process results from ionization of residual gas within the cathode/anode gap by the extracted electron beam, which is subsequently accelerated backwards to the photocathode. The damage mechanism is believed to be either destruction of the negative electron affinity condition at the surface of the photocathode or damage to the crystal structure by implantation of the bombarding ions. This work characterizes ion formation within the anode/cathode gap for gas species typical of UHV vacuum chambers (i.e., hydrogen, carbon monoxide and methane). Calculations and simulations are performed to determine the ion trajectories and stopping distance within the photocathode material. The results of the simulations are compared with test results obtained using a 100 keV DC high voltage GaAs photoemission gun and beamline at currents up to 10 mA D...

  8. Optimization of a triode-type cusp electron gun for a W-band gyro-TWA

    Science.gov (United States)

    Zhang, Liang; Donaldson, Craig R.; He, Wenlong

    2018-04-01

    A triode-type cusp electron gun was optimized through numerical simulations for a W-band gyrotron traveling wave amplifier. An additional electrode in front of the cathode could switch the electron beam on and off instantly when its electric potential is properly biased. An optimal electron beam of current 1.7 A and a velocity ratio (alpha) of 1.12 with an alpha spread of ˜10.7% was achieved when the triode gun was operated at 40 kV.

  9. Experimental investigation of a 1 kA/cm² sheet beam plasma cathode electron gun.

    Science.gov (United States)

    Kumar, Niraj; Pal, Udit Narayan; Pal, Dharmendra Kumar; Prajesh, Rahul; Prakash, Ram

    2015-01-01

    In this paper, a cold cathode based sheet-beam plasma cathode electron gun is reported with achieved sheet-beam current density ∼1 kA/cm(2) from pseudospark based argon plasma for pulse length of ∼200 ns in a single shot experiment. For the qualitative assessment of the sheet-beam, an arrangement of three isolated metallic-sheets is proposed. The actual shape and size of the sheet-electron-beam are obtained through a non-conventional method by proposing a dielectric charging technique and scanning electron microscope based imaging. As distinct from the earlier developed sheet beam sources, the generated sheet-beam has been propagated more than 190 mm distance in a drift space region maintaining sheet structure without assistance of any external magnetic field.

  10. Extreme regimes of femtosecond photoemission from a copper cathode in a dc electron gun

    Directory of Open Access Journals (Sweden)

    P. L. E. M. Pasmans

    2016-10-01

    Full Text Available The femtosecond photoemission yield from a copper cathode and the emittance of the created electron beams has been studied in a 12  MeV/m, 100 keV dc electron gun over a wide range of laser fluence, from the linear photoemission regime until the onset of image charge limitations and cathode damaging. The measured photoemission curves can be described well with available theory which includes the Schottky effect, second-order photoemission, and image charge limitation. The second-order photoemission can be explained by thermally assisted one-photon photoemission (1PPE and by above-threshold two-photon photoemission (2PPE. Measurements with a fresh cathode suggest that the 2PPE process is dominant. The beam emittance has been measured for the entire range of initial surface charge densities as well. The emittance measurements of space-charge dominated beams can be described well by an envelope equation with generalized perveance. The dc gun produces 0.1 pC bunches with 25 nm rms normalized emittance, corresponding to a normalized brightness usually associated with rf photoguns. In this experimental study the limits of femtosecond photoemission from a copper cathode have been explored and analyzed in great detail, resulting in improved understanding of the underlying mechanisms.

  11. Timing jitter measurements at the SLC electron source

    International Nuclear Information System (INIS)

    Sodja, J.; Browne, M.J.; Clendenin, J.E.

    1989-03-01

    The SLC thermionic gun and electron source produce a beam of up to 15 /times/ 10 10 /sub e//minus/ in a single S-band bunch. A 170 keV, 2 ns FWHM pulse out of the gun is compressed by means of two subharmonic buncher cavities followed by an S-band buncher and a standard SLAC accelerating section. Ceramic gaps in the beam pipe at the output of the gun allow a measure of the beam intensity and timing. A measurement at these gaps of the timing jitter, with a resolution of <10 ps, is described. 3 refs., 5 figs

  12. Design of full digital 50 kV electronic gun high voltage power supply

    International Nuclear Information System (INIS)

    Ge Lei; Shang Lei

    2014-01-01

    The design of full digital electronic gun high voltage power supply based on DSP was introduced in this paper. This power supply has innovations of full digital feedback circuit and PID closed-loop control mode. The application of high frequency resonant converter circuit reduces the size of the resonant element and transformer. The current-coupling distributed high voltage transformer and rectifier circuit were employed in this power supply. By this way, the power supply efficiency is improved and the number of distributed parameters is reduced, and the rectifier circuit could work under the oil-free environment. This power supply has been used in electronic grid-control high voltage system of the irradiation accelerator. (authors)

  13. A tapered multi-gap multi-aperture pseudospark-sourced electron gun based X-band slow wave oscillator

    Science.gov (United States)

    Kumar, N.; Lamba, R. P.; Hossain, A. M.; Pal, U. N.; Phelps, A. D. R.; Prakash, R.

    2017-11-01

    The experimental study of a tapered, multi-gap, multi-aperture pseudospark-sourced electron gun based X-band plasma assisted slow wave oscillator is presented. The designed electron gun is based on the pseudospark discharge concept and has been used to generate a high current density and high energy electron beam simultaneously. The distribution of apertures has been arranged such that the field penetration potency inside the backspace of the hollow-cathode is different while passing through the tapered gap region. This leads to non-concurrent ignition of the discharge through all the channels which is, in general, quite challenging in the case of multi-aperture plasma cathode electron gun geometries. Multiple and successive hollow cathode phases are reported from this electron gun geometry, which have been confirmed using simulations. This geometry also has led to the achievement of ˜71% fill factor inside the slow wave oscillator for an electron beam of energy of 20 keV and a beam current density in the range of 115-190 A/cm2 at a working argon gas pressure of 18 Pa. The oscillator has generated broadband microwave output in the frequency range of 10-11.7 GHz with a peak power of ˜10 kW for ˜50 ns.

  14. Mechanical design and fabrication of the VHF-gun, the Berkeley normal-conducting continuous-wave high-brightness electron source

    Science.gov (United States)

    Wells, R. P.; Ghiorso, W.; Staples, J.; Huang, T. M.; Sannibale, F.; Kramasz, T. D.

    2016-02-01

    A high repetition rate, MHz-class, high-brightness electron source is a key element in future high-repetition-rate x-ray free electron laser-based light sources. The VHF-gun, a novel low frequency radio-frequency gun, is the Lawrence Berkeley National Laboratory (LBNL) response to that need. The gun design is based on a normal conducting, single cell cavity resonating at 186 MHz in the VHF band and capable of continuous wave operation while still delivering the high accelerating fields at the cathode required for the high brightness performance. The VHF-gun was fabricated and successfully commissioned in the framework of the Advanced Photo-injector EXperiment, an injector built at LBNL to demonstrate the capability of the gun to deliver the required beam quality. The basis for the selection of the VHF-gun technology, novel design features, and fabrication techniques are described.

  15. Rf Gun with High-Current Density Field Emission Cathode

    International Nuclear Information System (INIS)

    Jay L. Hirshfield

    2005-01-01

    High current-density field emission from an array of carbon nanotubes, with field-emission-transistor control, and with secondary electron channel multiplication in a ceramic facing structure, have been combined in a cold cathode for rf guns and diode guns. Electrodynamic and space-charge flow simulations were conducted to specify the cathode configuration and range of emission current density from the field emission cold cathode. Design of this cathode has been made for installation and testing in an existing S-band 2-1/2 cell rf gun. With emission control and modulation, and with current density in the range of 0.1-1 kA/cm2, this cathode could provide performance and long-life not enjoyed by other currently-available cathodes

  16. Design of Control System Device for Electron Gun Power Supply of 350 keV/10 mA Electron Beam Machine

    International Nuclear Information System (INIS)

    Eko Priyono; Budi Santosa; Taxwim

    2003-01-01

    The electron gun power supply control system of electron beam machine has been designed. Using this design regulator device for the electron gun power supply will be constructed. This regulator device was designed that it can be operated manually or automatically. Beside that, this was also provided with the safety system which is useful to scram the MBE when something wrong happened. The main components of the device are remote data communication system using infra red and fiber optic module, DC motor driver system, regulated transformer coupled by DC motor and operation panel system. (author)

  17. Analysis of Mig-type electron guns for a 35GHz gyrotron

    International Nuclear Information System (INIS)

    Barroso, J.J.; Galvao, G.P.

    1988-05-01

    A 35GHz gyrotron is currently under construction at the Associated Plasma Laboratory of the Institute for Space Research to be used in plasma heating and noninductive current drive experiments. A critical component of the device is the electrooptical system, which must generate a beam with low velocity spread and high transverse energy. One way to decrease the velocity spread is to use laminar beams. For laminar flow, where the trajectories do not cross, the axial component of the space-charge forces changes sign each half cycle models of magnetron injection guns that produce laminar beams are analyzed and procedures for controlling the pitch angle parameter, which defines the transverse-to-axial electron velocity ratio are investigated. (author)

  18. Development of a high brightness electron gun for the Accelerator Test Facility at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Batchelor, K.; Kirk, H.; Sheehan, J.; Woodle, M.; McDonald, K.

    1988-01-01

    An electron gun utilizing a radio frequency accelerating cavity operating at a frequency of 2856 MHZ is described. Low level tests of a model cavity designed for use with either a thermionic or laser driven photo-cathode are presented. Calculations for a laser driven photo-cathode at a bunch charge of 1nC in a 5 psec bunch are given. With this configuration we hope to achieve an emittance (γσ/sub x/σ/sub x/) of 5 to 10 /times/ 10/sup /minus/6/ m /center dot/ rad at an output energy of 4.85 MeV for a 1nC charge. 9 refs., 10 figs., 4 tabs

  19. A 600-kV double-pulser for the PHERMEX electron gun

    Energy Technology Data Exchange (ETDEWEB)

    Carlson, R.L.; Kang, M.; Melton, J.G.; Seitz, G.J.; Trujillo, L.T.

    1997-09-01

    The PHERMEX (Pulsed High Energy Radiographic Machine Emitting X-rays) Radiographic Facility is a 50-MHz, 3-Cavity, RF-Linac driven by a pulsed, thermionic electron-gun Injector. The PHERMEX is used to take flash radiographs using x-rays at a single time in an explosively driven event. To investigate the time evolution of these events requires two things: (1) a multiple-pulser to drive the electron-gun Injector and (2) a large-format, gamma-ray, camera system to record a scintillator at the different times. The authors report the recent success of developing a reliable double-pulser that consists of two Marx generators that independently charge two PFLs that are switched out at about 1.4 MV. The PFLs are connected in series by large diaphragm switches that are independently laser triggered by two quadrupled-YAG lasers. Recent tests of the system into a dummy load, produced two high quality 600 kV pulses separated by 1.0 {micro}s. Each pulse has a FWHM of 90 ns, a 50 ns flat-top {+-} 3%, and a risetime of 25 ns and a falltime of 35 ns. The interpulse time is variable up to about 275 {micro}s; the first switch is kept closed by a keep alive inductor. The system has produced a 50 shot sequence of two pulses with a 1-sigma jitter < 1 ns. The system has been modeled using TOSCA-3D, FLUX-2D, and a transmission line model run with the circuits code Micro-CAP.

  20. A 600-kV double-pulser for the PHERMEX electron gun

    International Nuclear Information System (INIS)

    Carlson, R.L.; Kang, M.; Melton, J.G.; Seitz, G.J.; Trujillo, L.T.

    1997-01-01

    The PHERMEX (Pulsed High Energy Radiographic Machine Emitting X-rays) Radiographic Facility is a 50-MHz, 3-Cavity, RF-Linac driven by a pulsed, thermionic electron-gun Injector. The PHERMEX is used to take flash radiographs using x-rays at a single time in an explosively driven event. To investigate the time evolution of these events requires two things: (1) a multiple-pulser to drive the electron-gun Injector and (2) a large-format, gamma-ray, camera system to record a scintillator at the different times. The authors report the recent success of developing a reliable double-pulser that consists of two Marx generators that independently charge two PFLs that are switched out at about 1.4 MV. The PFLs are connected in series by large diaphragm switches that are independently laser triggered by two quadrupled-YAG lasers. Recent tests of the system into a dummy load, produced two high quality 600 kV pulses separated by 1.0 micros. Each pulse has a FWHM of 90 ns, a 50 ns flat-top ± 3%, and a risetime of 25 ns and a falltime of 35 ns. The interpulse time is variable up to about 275 micros; the first switch is kept closed by a keep alive inductor. The system has produced a 50 shot sequence of two pulses with a 1-sigma jitter < 1 ns. The system has been modeled using TOSCA-3D, FLUX-2D, and a transmission line model run with the circuits code Micro-CAP

  1. Analysis of Premature Wear-Out of Aircraft Gun Barrel by Applying a Transmission Electron Microscopy (TEM

    Directory of Open Access Journals (Sweden)

    Łęczycki Krzysztof

    2017-08-01

    Full Text Available Firing from gun armament generates a wide range of physico-chemical phenomena contributing to the degradation of barrel material, e.g. pressure, high temperature, chemically aggressive character of post-detonation gases and friction of a driving band. In this work the technique of thin foils was used in Transmission Electron Microscopy (TEM to study the influence of physicochemical phenomena on the material microstructure of aircraft gun barrel. A mechanism and reason of premature wear-out of the barrel under consideration was also outlined by utilising light microscopy and hardness measurements.

  2. Conceptual design of a bright electron injector based on a laser-driven photocathode rf electron gun

    International Nuclear Information System (INIS)

    Chattopadhyay, S.; Chen, Y.J.; Hopkins, D.; Kim, K.J.; Kung, A.; Miller, R.; Sessler, A.; Young, T.

    1988-09-01

    Conceptual design of a bright electron injector for the 1 GeV high gradient test experiment, envisaged by the LLNL-SLAC-LBL collaboration on the Relativistic Klystron is presented. The design utilizes a high-brightness laser-driven rf photocathode electron gun, similar to the pioneering LANL early studies in concept (different parametrically however), together with achromatic magnetic bunching and transport systems and diagnostics. The design is performed with attention to possible use in an FEL as well. A simple but realistic analytic model including longitudinal and transverse space-charge and rf effects and extensive computer simulation form the basis of the parametric choice for the source. These parameters are used as guides for the design of the picosecond laser system and magnetic bunching section. 4 refs., 5 figs., 2 tabs

  3. Adaptive electron beam shaping using a photoemission gun and spatial light modulator

    Directory of Open Access Journals (Sweden)

    Jared Maxson

    2015-02-01

    Full Text Available The need for precisely defined beam shapes in photoelectron sources has been well established. In this paper, we use a spatial light modulator and simple shaping algorithm to create arbitrary, detailed transverse laser shapes with high fidelity. We transmit this shaped laser to the photocathode of a high voltage dc gun. Using beam currents where space charge is negligible, and using an imaging solenoid and fluorescent viewscreen, we show that the resultant beam shape preserves these detailed features with similar fidelity. Next, instead of transmitting a shaped laser profile, we use an active feedback on the unshaped electron beam image to create equally accurate and detailed shapes. We demonstrate that this electron beam feedback has the added advantage of correcting for electron optical aberrations, yielding shapes without skew. The method may serve to provide precisely defined electron beams for low current target experiments, space-charge dominated beam commissioning, as well as for online adaptive correction of photocathode quantum efficiency degradation.

  4. Simulation of the Beam Dump for a High Intensity Electron Gun

    CERN Document Server

    Doebert, S; Lefevre, T; Pepitone, K

    2014-01-01

    The CLIC Drive Beam is a high-intensity pulsed electron beam. A test facility for the Drive Beam electron gun will soon be commissioned at CERN. In this contribution we outline the design of a beam dump / Faraday cup capable of resisting the beam’s thermal load. The test facility will operate initially up to 140 keV. At such low energies, the electrons are absorbed very close to the surface of the dump, leading to a large energy deposition density in this thin layer. In order not to damage the dump, the beam must be spread over a large surface. For this reason, a small-angled cone has been chosen. Simulations using Geant4 have been performed to estimate the distribution of energy deposition in the dump. The heat transport both within the electron pulse and between pulses has been modelled using finite element methods to check the resistance of the dump at high repetition rates. In addition, the possibility of using a moveable dump to measure the beam profile and emittance is discussed.

  5. RF guns: a review

    International Nuclear Information System (INIS)

    Travier, C.

    1990-06-01

    Free Electron Lasers and future linear colliders require very bright electron beams. Conventional injectors made of DC guns and RF bunchers have intrinsic limitations. The recently proposed RF guns have already proven their capability to produce bright beams. The necessary effort to improve further these performances and to gain reliability is now undertaken by many laboratories. More than twenty RF gun projects both thermionic and laser-driven are reviewed. Their specific characteristics are outlined and their nominal performances are given

  6. A multiple gap plasma cathode electron gun and its electron beam analysis in self and trigger breakdown modes.

    Science.gov (United States)

    Kumar, Niraj; Pal, Dharmendra Kumar; Jadon, Arvind Singh; Pal, Udit Narayan; Rahaman, Hasibur; Prakash, Ram

    2016-03-01

    In the present paper, a pseudospark discharge based multiple gap plasma cathode electron gun is reported which has been operated separately in self and trigger breakdown modes using two different gases, namely, argon and hydrogen. The beam current and beam energy have been analyzed using a concentric ring diagnostic arrangement. Two distinct electron beams are clearly seen with hollow cathode and conductive phases. The hollow cathode phase has been observed for ∼50 ns where the obtained electron beam is having low beam current density and high energy. While in conductive phase it is high current density and low energy electron beam. It is inferred that in the hollow cathode phase the beam energy is more for the self breakdown case whereas the current density is more for the trigger breakdown case. The tailor made operation of the hollow cathode phase electron beam can play an important role in microwave generation. Up to 30% variation in the electron beam energy has been achieved keeping the same gas and by varying the breakdown mode operations. Also, up to 32% variation in the beam current density has been achieved for the trigger breakdown mode at optimized trigger position by varying the gas type.

  7. A multiple gap plasma cathode electron gun and its electron beam analysis in self and trigger breakdown modes

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Niraj; Pal, Udit Narayan; Prakash, Ram [CSIR-Central Electronics Engineering Research Institute (CSIR-CEERI), Pilani, Rajasthan 333031 (India); Academy of Scientific and Innovative Research (AcSIR), CSIR-CEERI Campus, Pilani (India); Pal, Dharmendra Kumar; Jadon, Arvind Singh; Rahaman, Hasibur [CSIR-Central Electronics Engineering Research Institute (CSIR-CEERI), Pilani, Rajasthan 333031 (India)

    2016-03-15

    In the present paper, a pseudospark discharge based multiple gap plasma cathode electron gun is reported which has been operated separately in self and trigger breakdown modes using two different gases, namely, argon and hydrogen. The beam current and beam energy have been analyzed using a concentric ring diagnostic arrangement. Two distinct electron beams are clearly seen with hollow cathode and conductive phases. The hollow cathode phase has been observed for ∼50 ns where the obtained electron beam is having low beam current density and high energy. While in conductive phase it is high current density and low energy electron beam. It is inferred that in the hollow cathode phase the beam energy is more for the self breakdown case whereas the current density is more for the trigger breakdown case. The tailor made operation of the hollow cathode phase electron beam can play an important role in microwave generation. Up to 30% variation in the electron beam energy has been achieved keeping the same gas and by varying the breakdown mode operations. Also, up to 32% variation in the beam current density has been achieved for the trigger breakdown mode at optimized trigger position by varying the gas type.

  8. A multiple gap plasma cathode electron gun and its electron beam analysis in self and trigger breakdown modes

    International Nuclear Information System (INIS)

    Kumar, Niraj; Pal, Udit Narayan; Prakash, Ram; Pal, Dharmendra Kumar; Jadon, Arvind Singh; Rahaman, Hasibur

    2016-01-01

    In the present paper, a pseudospark discharge based multiple gap plasma cathode electron gun is reported which has been operated separately in self and trigger breakdown modes using two different gases, namely, argon and hydrogen. The beam current and beam energy have been analyzed using a concentric ring diagnostic arrangement. Two distinct electron beams are clearly seen with hollow cathode and conductive phases. The hollow cathode phase has been observed for ∼50 ns where the obtained electron beam is having low beam current density and high energy. While in conductive phase it is high current density and low energy electron beam. It is inferred that in the hollow cathode phase the beam energy is more for the self breakdown case whereas the current density is more for the trigger breakdown case. The tailor made operation of the hollow cathode phase electron beam can play an important role in microwave generation. Up to 30% variation in the electron beam energy has been achieved keeping the same gas and by varying the breakdown mode operations. Also, up to 32% variation in the beam current density has been achieved for the trigger breakdown mode at optimized trigger position by varying the gas type.

  9. Diagnostic for a high-repetition rate electron photo-gun and first measurements

    Science.gov (United States)

    Filippetto, D.; Doolittle, L.; Huang, G.; Norum, E.; Portmann, G.; Qian, H.; Sannibale, F.

    2015-05-01

    The APEX electron source at LBNL combines the high-repetition-rate with the high beam brightness typical of photoguns, delivering low emittance electron pulses at MHz frequency. Proving the high beam quality of the beam is an essential step for the success of the experiment, opening the doors of the high average power to brightness-hungry applications as X-Ray FELs, MHz ultrafast electron diffraction etc.. As first step, a complete characterization of the beam parameters is foreseen at the Gun beam energy of 750 keV. Diagnostics for low and high current measurements have been installed and tested, and measurements of cathode lifetime and thermal emittance in a RF environment with mA current performed. The recent installation of a double slit system, a deflecting cavity and a high precision spectrometer, allow the exploration of the full 6D phase space. Here we discuss the present layout of the machine and future upgrades, showing the latest results at low and high repetition rate, together with the tools and techniques used.

  10. Modular Low-Heater-Power Cathode/Electron Gun Assembly for Microwave and Millimeter Wave Traveling Wave Tubes

    Science.gov (United States)

    Wintucky, Edwin G.

    2000-01-01

    A low-cost, low-mass, electrically efficient, modular cathode/electron gun assembly has been developed by FDE Inc. of Beaverton, Oregon, under a Small Business Innovation Research (SBIR) contract with the NASA Glenn Research Center at Lewis Field. This new assembly offers significant improvements in the design and manufacture of microwave and millimeter wave traveling-wave tubes (TWT's) used for radar and communications. It incorporates a novel, low-heater-power, reduced size and mass, high-performance barium dispenser type thermionic cathode and provides for easy integration of the cathode into a large variety of conventional TWT circuits. Among the applications are TWT's for Earth-orbiting communication satellites and for deep space communications, where future missions will require smaller spacecraft, higher data transfer rates (higher frequencies and radiofrequency output power), and greater electrical efficiency. A particularly important TWT application is in the microwave power module (a hybrid microwave/millimeter wave amplifier consisting of a low-noise solid-state driver, a small TWT, and an electronic power conditioner integrated into a single compact package), where electrical efficiency and thermal loading are critical factors and lower cost is needed for successful commercialization. The design and fabrication are based on practices used in producing cathode ray tubes (CRT's), which is one of the most competitive and efficient manufacturing operations in the world today. The approach used in the design and manufacture of thermionic cathodes and electron guns for CRT's has been optimized for fully automated production, standardization of parts, and minimization of costs. It is applicable to the production of similar components for microwave tubes, with the additional benefits of low mass and significantly lower cathode heater power (less than half that of dispenser cathodes presently used in TWT s). Modular cathode/electron gun assembly. The modular

  11. Multiobjective optimizations of a novel cryocooled dc gun based ultrafast electron diffraction beam line

    Directory of Open Access Journals (Sweden)

    Colwyn Gulliford

    2016-09-01

    Full Text Available We present the results of multiobjective genetic algorithm optimizations of a single-shot ultrafast electron diffraction beam line utilizing a 225 kV dc gun with a novel cryocooled photocathode system and buncher cavity. Optimizations of the transverse projected emittance as a function of bunch charge are presented and discussed in terms of the scaling laws derived in the charge saturation limit. Additionally, optimization of the transverse coherence length as a function of final rms bunch length at the sample location have been performed for three different sample radii: 50, 100, and 200  μm, for two final bunch charges: 10^{5} electrons (16 fC and 10^{6} electrons (160 fC. Example optimal solutions are analyzed, and the effects of disordered induced heating estimated. In particular, a relative coherence length of L_{c,x}/σ_{x}=0.27  nm/μm was obtained for a final bunch charge of 10^{5} electrons and final bunch length of σ_{t}≈100  fs. For a final charge of 10^{6} electrons the cryogun produces L_{c,x}/σ_{x}≈0.1  nm/μm for σ_{t}≈100–200  fs and σ_{x}≥50  μm. These results demonstrate the viability of using genetic algorithms in the design and operation of ultrafast electron diffraction beam lines.

  12. A compact CMA spectrometer with axially integrated hybrid electron-ion gun for ISS, AES and sputter depth profile analysis

    International Nuclear Information System (INIS)

    Gisler, E.; Bas, E.B.

    1986-01-01

    Until now, the combined application of electrons and ions in surface analysis required two separate sources for electrons and ions with different incidence angles. The newly developed hybrid electron-ion gun, however, allows bombardment of the same sample area both with noble gas ions and with electrons coming from the same direction. By integrating such a hybrid gun axially in a cylindrical mirror energy analyser (CMA) a sensitive compact single flange spectrometer obtains for ion scattering spectroscopy (ISS), Auger electron spectroscopy (AES), and sputtering all within normal beam incidence. This concept makes accurate beam centering very easy. Additionally, the bombardment from the same direction both for sputtering and for surface analysis brings advantages in depth profiling. The scattering angle for ISS has a constant value of about 138 0 . The hybrid gun delivers typically an electron beam current of -20μA at 3keV for AES, and an ion beam current of +40 nA and +1.2μA at 2 keV for ISS and sputtering respectively. The switching time between ISS, AES, and sputtering mode is about 0.1 s. So this system is best suited for automatically controlled depth profile analysis. The design and operation of this new system will be described and some applications will be discussed. (author)

  13. Gun Play

    Science.gov (United States)

    Mechling, Jay

    2008-01-01

    Biology and the particular gun culture of the United States come together to explain the persistent and powerful attraction of American boys to both real guns and toy guns. The 1990s saw adults begin to conflate "the gun problem" with "the boy problem," sparking attempts (largely failed) to banish toy guns from homes and…

  14. Focussed ion beam thin sample microanalysis using a field emission gun electron probe microanalyser

    Science.gov (United States)

    Kubo, Y.

    2018-01-01

    Field emission gun electron probe microanalysis (FEG-EPMA) in conjunction with wavelength-dispersive X-ray spectrometry using a low acceleration voltage (V acc) allows elemental analysis with sub-micrometre lateral spatial resolution (SR). However, this degree of SR does not necessarily meet the requirements associated with increasingly miniaturised devices. Another challenge related to performing FEG-EPMA with a low V acc is that the accuracy of quantitative analyses is adversely affected, primarily because low energy X-ray lines such as the L- and M-lines must be employed and due to the potential of line interference. One promising means of obtaining high SR with FEG-EPMA is to use thin samples together with high V acc values. This mini-review covers the basic principles of thin-sample FEG-EPMA and describes an application of this technique to the analysis of optical fibres. Outstanding issues related to this technique that must be addressed are also discussed, which include the potential for electron beam damage during analysis of insulating materials and the development of methods to use thin samples for quantitative analysis.

  15. Current control of the electron beam formed in the magnetron gun with a secondary-emission cathode

    International Nuclear Information System (INIS)

    Dovbnya, A.N.; Reshetnyak, N.G.; Zakutin, V.V.; Chertishchev, I.A.; Romas'ko, V.P.; Dovbnyan, N.A.

    2013-01-01

    Data are reported on electron beam generation and beam current control in two types of secondary-emission cathode magnetron guns. The influence of the magnetic field value and field distribution on the formation of the beam and its parameters has been investigated in the electron energy range between 20 and 150 keV. The influence of local magnetic field variations on the cathode and the electron beam characteristics has been studied. The possibility to control the electron beam current in various ways has been demonstrated

  16. Multiobjective optimization design of an rf gun based electron diffraction beam line

    Directory of Open Access Journals (Sweden)

    Colwyn Gulliford

    2017-03-01

    Full Text Available Multiobjective genetic algorithm optimizations of a single-shot ultrafast electron diffraction beam line comprised of a 100  MV/m 1.6-cell normal conducting rf (NCRF gun, as well as a nine-cell 2π/3 bunching cavity placed between two solenoids, have been performed. These include optimization of the normalized transverse emittance as a function of bunch charge, as well as optimization of the transverse coherence length as a function of the rms bunch length of the beam at the sample location for a fixed charge of 10^{6} electrons. Analysis of the resulting solutions is discussed in terms of the relevant scaling laws, and a detailed description of one of the resulting solutions from the coherence length optimizations is given. For a charge of 10^{6} electrons and final beam sizes of σ_{x}≥25  μm and σ_{t}≈5  fs, we found a relative coherence length of L_{c,x}/σ_{x}≈0.07 using direct optimization of the coherence length. Additionally, based on optimizations of the emittance as a function of final bunch length, we estimate the relative coherence length for bunch lengths of 30 and 100 fs to be roughly 0.1 and 0.2  nm/μm, respectively. Finally, using the scaling of the optimal emittance with bunch charge, for a charge of 10^{5} electrons, we estimate relative coherence lengths of 0.3, 0.5, and 0.92  nm/μm for final bunch lengths of 5, 30 and 100 fs, respectively.

  17. High voltage performance of a dc photoemission electron gun with centrifugal barrel-polished electrodes

    Science.gov (United States)

    Hernandez-Garcia, C.; Bullard, D.; Hannon, F.; Wang, Y.; Poelker, M.

    2017-09-01

    The design and fabrication of electrodes for direct current (dc) high voltage photoemission electron guns can significantly influence their performance, most notably in terms of maximum achievable bias voltage. Proper electrostatic design of the triple-point junction shield electrode minimizes the risk of electrical breakdown (arcing) along the insulator-cable plug interface, while the electrode shape is designed to maintain work, we describe a centrifugal barrel-polishing technique commonly used for polishing the interior surface of superconducting radio frequency cavities but implemented here for the first time to polish electrodes for dc high voltage photoguns. The technique reduced polishing time from weeks to hours while providing surface roughness comparable to that obtained with diamond-paste polishing and with unprecedented consistency between different electrode samples. We present electrode design considerations and high voltage conditioning results to 360 kV (˜11 MV/m), comparing barrel-polished electrode performance to that of diamond-paste polished electrodes. Tests were performed using a dc high voltage photogun with an inverted-geometry ceramic insulator design.

  18. Method for Designing Electronic Assemblies without Potting for Gun Launched Applications Through the Use of Additive Manufacturing

    Science.gov (United States)

    2016-12-01

    Respondents should be aware that notwithstanding any other provision of law , no person shall be subject to any penalty for failing to comply with a...catch (SCAT) gun Guidance electronics On-board recorder (OBR) Precision guided munition (PGM) 16. SECURITY CLASSIFICATION OF: 17...12 All 22 spacer revisions in order from left to right and top to bottom 12 13 Reference for dimension definitions for revisions 1 through 9 13 14

  19. A high-gradient high-duty-factor Rf photo-cathode electron gun

    International Nuclear Information System (INIS)

    Rimmer, Robert A.; Hartman, Neal; Lidia, Steven M.; Wang, Shaoheng

    2002-01-01

    We describe the analysis and preliminary design of a high-gradient, high-duty factor RF photocathode gun. The gun is designed to operate at high repetition rate or CW, with high gradient on the cathode surface to minimize emittance growth due to space charge forces at high bunch charge. The gun may also be operated in a solenoidal magnetic field for emittance compensation. The design is intended for use in short-pulse, high-charge, and high-repetition rate applications such as linac based X-ray sources. We present and compare the results of gun simulations using different codes, as well as RF and thermal analysis of the structure

  20. A high-gradient high-duty-factor RF photo-cathode electron gun

    International Nuclear Information System (INIS)

    Rimmer, Robert; Hartman, N.; Lidia, S.; Wang, S.H.

    2002-01-01

    We describe the analysis and preliminary design of a high-gradient, high-duty factor RF photocathode gun. The gun is designed to operate at high repetition rate or CW, with high gradient on the cathode surface to minimize emittance growth due to space charge forces at high bunch charge. The gun may also be operated in a solenoidal magnetic field for emittance compensation. The design is intended for use in short-pulse, high-charge, and high-repetition rate applications such as linac based X-ray sources. We present and compare the results of gun simulations using different codes, as well as RF and thermal analysis of the structure

  1. Modification of anisotropic plasma diffusion via auxiliary electrons emitted by a carbon nanotubes-based electron gun in an electron cyclotron resonance ion source.

    Science.gov (United States)

    Malferrari, L; Odorici, F; Veronese, G P; Rizzoli, R; Mascali, D; Celona, L; Gammino, S; Castro, G; Miracoli, R; Serafino, T

    2012-02-01

    The diffusion mechanism in magnetized plasmas is a largely debated issue. A short circuit model was proposed by Simon, assuming fluxes of lost particles along the axial (electrons) and radial (ions) directions which can be compensated, to preserve the quasi-neutrality, by currents flowing throughout the conducting plasma chamber walls. We hereby propose a new method to modify Simon's currents via electrons injected by a carbon nanotubes-based electron gun. We found this improves the source performances, increasing the output current for several charge states. The method is especially sensitive to the pumping frequency. Output currents for given charge states, at different auxiliary electron currents, will be reported in the paper and the influence of the frequency tuning on the compensation mechanism will be discussed.

  2. Generation of nanosecond S band microwave pulses based on superradiance

    International Nuclear Information System (INIS)

    Ginzburg, N.S.; Zotova, I.V.; Rozental, R.M.

    2002-01-01

    Modeling carried out demonstrates possibility of generation of gigawatt power level S band microwave pulse with duration of several nanoseconds using superradiation of short electron beam moving along slow-wave periodical structure. A 10 ns / 500 keV / 5 kA accelerator of Kanazawa University can be used in such experiments. It is shown that significant increasing peak power can be obtained by optimization of voltage and current pulses waveforms. Required increasing of electron energy and current by the end of electron pulse can be achieved by using self-acceleration of a short beam passing through a system of passive cavities. (author)

  3. Generation of nanosecond S band microwave pulses based on superradiance

    Energy Technology Data Exchange (ETDEWEB)

    Ginzburg, N.S.; Zotova, I.V.; Rozental, R.M. [Russian Academy of Science, Institute of Applied Physics, Nizhny Novgorod (RU)] [and others

    2002-06-01

    Modeling carried out demonstrates possibility of generation of gigawatt power level S band microwave pulse with duration of several nanoseconds using superradiation of short electron beam moving along slow-wave periodical structure. A 10 ns / 500 keV / 5 kA accelerator of Kanazawa University can be used in such experiments. It is shown that significant increasing peak power can be obtained by optimization of voltage and current pulses waveforms. Required increasing of electron energy and current by the end of electron pulse can be achieved by using self-acceleration of a short beam passing through a system of passive cavities. (author)

  4. Experience with a radio frequency gun on the SSRL Injector Linac

    International Nuclear Information System (INIS)

    Weaver, J.N.; Genin, R.D.; Golceff, P.; Morales, H.; Sebek, J.

    1993-04-01

    A-SSRL/Varian-Associates-built, one-and-a-half cavity microwave, thermionic-cathode gun has operated on the SSRL Injector Linac reliably without changing the cathode for over 10,000 hours, with no significant decrease in emission. Thus, for a pulsed electron beam, with a maximum of 0.5 A peak at 2 to 3 MeV from a 3.5 MW peak rf pulse of 2 μs pulse width at 10 pps, the apparent but small amount of back bombardment of the cathode has been tolerable. Use of a bunch-compression alpha magnet and a stripline chopper after the gun produces the required S-band 3 to 5 microbunches of electrons for injection into a standard 10-m-long linac and on into a booster synchrotron, which in turn is used to fill SPEAR. Component limitations and operating characteristics of the gun and the linac's rf system are discussed

  5. An ion-sputtering gun to clean crystal surfaces in-situ in an ultra-high-vacuum electron microscope

    International Nuclear Information System (INIS)

    Morita, Etsuo; Takayanagi, Kunio; Kobayashi, Kunio; Yagi, Katsumichi; Honjo, Goro

    1980-01-01

    The design and performance of an ion-sputtering gun for cleaning crystal surfaces in-situ in an ultra-high-vacuum electron microscope are reported. The electron microscopic aspects of ion-bombardment damage to ionic magnesium oxide, covalent germanium and silicon, and metallic gold and copper crystals, and the effects of annealing after and during sputtering are described. The growth of various kinds of films deposited in-situ on crystals cleaned by ion-sputtering are described and discussed. (author)

  6. Project outline of high quality electron beam generation at Waseda University

    Energy Technology Data Exchange (ETDEWEB)

    Washio, M.; Hama, Y.; Kashiwagi, S.; Kuroda, R.; Kobuki, T. [Waseda Univ., Advanced Research Institute for Science and Engineering, Shinjuku, Tokyo (Japan); Hirose, T. [Tokyo Metropolitan Univ. (Japan). Dept. of Physics

    2000-03-01

    High quality electron beam generation project has been started at Waseda University under the grant of Ministry of Education, named High-Tech Research Center Project. In the project, we will install a laser photo-cathode RF Gun system with 1.6 accelerating structure cells of s-band and a stabilized RF power source. This RF Gun is expected to produce single electron bunch up to 1 or 2nC with around 10ps pulse duration. (author)

  7. Project outline of high quality electron beam generation at Waseda University

    International Nuclear Information System (INIS)

    Washio, M.; Hama, Y.; Kashiwagi, S.; Kuroda, R.; Kobuki, T.; Hirose, T.

    2000-01-01

    High quality electron beam generation project has been started at Waseda University under the grant of Ministry of Education, named High-Tech Research Center Project. In the project, we will install a laser photo-cathode RF Gun system with 1.6 accelerating structure cells of s-band and a stabilized RF power source. This RF Gun is expected to produce single electron bunch up to 1 or 2nC with around 10ps pulse duration. (author)

  8. TiN coated aluminum electrodes for DC high voltage electron guns

    International Nuclear Information System (INIS)

    Mamun, Md Abdullah A.; Elmustafa, Abdelmageed A.; Taus, Rhys; Forman, Eric; Poelker, Matthew

    2015-01-01

    Preparing electrodes made of metals like stainless steel, for use inside DC high voltage electron guns, is a labor-intensive and time-consuming process. In this paper, the authors report the exceptional high voltage performance of aluminum electrodes coated with hard titanium nitride (TiN). The aluminum electrodes were comparatively easy to manufacture and required only hours of mechanical polishing using silicon carbide paper, prior to coating with TiN by a commercial vendor. The high voltage performance of three TiN-coated aluminum electrodes, before and after gas conditioning with helium, was compared to that of bare aluminum electrodes, and electrodes manufactured from titanium alloy (Ti-6Al-4V). Following gas conditioning, each TiN-coated aluminum electrode reached −225 kV bias voltage while generating less than 100 pA of field emission (<10 pA) using a 40 mm cathode/anode gap, corresponding to field strength of 13.7 MV/m. Smaller gaps were studied to evaluate electrode performance at higher field strength with the best performing TiN-coated aluminum electrode reaching ∼22.5 MV/m with field emission less than 100 pA. These results were comparable to those obtained from our best-performing electrodes manufactured from stainless steel, titanium alloy and niobium, as reported in references cited below. The TiN coating provided a very smooth surface and with mechanical properties of the coating (hardness and modulus) superior to those of stainless steel, titanium-alloy, and niobium electrodes. These features likely contributed to the improved high voltage performance of the TiN-coated aluminum electrodes

  9. RF Design and Operating Performance of the BNL/AES 1.3 GHz Single Cell Superconducting RF Photocathode Electron Gun

    International Nuclear Information System (INIS)

    Cole, Michael; Kneisel, Peter; Ben-Zvi, Ilan; Burrill, Andrew; Hahn, H.; Rao, Triveni; Zhao, Y.

    2005-01-01

    Over the past several years Advanced Energy Systems and BNL have been collaborating on the development and testing of a fully superconducting photocathode electron gun. Over the past year we have begun to realize significant results which have been published elsewhere (1). This paper will review the RF design of the gun under test and present results of its performance under various operating conditions. Results for cavity quality factor will be presented for various operating temperatures and cavity field gradients. We will also discuss future plans for testing using this gun.

  10. Broadband S-band class E HPA

    NARCIS (Netherlands)

    Wanum, M.; van Dijk, R.; de Hek, A.P.; van Vliet, Frank Edward

    2009-01-01

    A broadband class E High Power Amplifier (HPA) is presented. This HPA is designed to operate at S-band (2.75 to 3.75 GHz). A power added efficiency of 50% is obtained for the two stage amplifier with an output power of 35.5 dBm on a chip area of 5.25 times 2.8 mm2.

  11. RF Processing Experience with the GTF Prototype RF Gun

    International Nuclear Information System (INIS)

    Schmerge, J.F.

    2010-01-01

    The SSRL Gun Test Facility (GTF) was built to develop a high brightness electron injector for the LCLS and has been operational since 1996. A total of five different metal cathodes (4 Cu and 1 Mg) have been installed on the GTF gun. The rf processing history with the different cathodes will be presented including peak field achieved at the cathode. The LCLS gun is intended to operate at 120 MV/m and fields up to 140 MV/m have been achieved in the GTF gun. After installing a new cathode the number of rf pulses required to reach 120 MV/m is approximately 5-10 million. Total emitted dark current and Fowler Nordheim plots are also shown over the life of the cathode. The GTF photo-injector gun is an S-band standing-wave structure, with two resonant cavities and an intervening thick washer (Figure 1). The flat, back wall of the first cavity is a copper plate that serves as photocathode when illuminated with ultraviolet light from a pulsed, high-power laser. RF power enters the gun through an iris on the outer wall of the second cavity, and is coupled to the first through the axial opening of the washer. The first cavity is often referred to as a half cell, because its full-cell length has been truncated by the cathode plate and the second cavity is called the full cell. The gun is designed to operate in a π mode, with the peak field on axis in each cell approximately equal. The maximum in the half cell occurs at the cathode, and in the full cell near the center of the cavity. The field profile and tuning procedures are discussed in a separate tech note (1).

  12. Robe Development for Electrical Conductivity Analysis in an Electron Gun Produced Helium Plasma

    Science.gov (United States)

    Bragg-Sitton, Shannon M.; Bitteker, Leo; Rodgers, Stephen L. (Technical Monitor)

    2002-01-01

    The use of magnetohydrodynamic (MHD) power conversion systems, potentially coupled with a fission power source, is currently being investigated as a driver for an advanced propulsion system, such as a plasma thruster. The efficiency of a MHD generator is strongly dependent on the electrical conductivity of the fluid that passes through the generator; power density increases as fluid conductivity increases. Although traditional MHD flows depend on thermal ionization to enhance the electrical conductivity, ionization due to nuclear interactions may achieve a comparable or improved conductivity enhancement while avoiding many of the limitations inherent to thermal ionization. Calculations suggest that nuclear-enhanced electrical conductivity increases as the neutron flux increases; conductivity of pure He-3 greater than 10 mho/m may be achievable if exposed to a flux greater than 10(exp 12) neutrons/cm2/s.) However, this remains to be demonstrated experimentally. An experimental facility has been constructed at the Propulsion Research Center at the NASA Marshall Space Flight Center, using helium as the test fluid. High energy electrons will be used to simulate the effects of neutron-induced ionization of helium gas to produce a plasma. These experiments will be focused on diagnosis of the plasma in a virtually static system; results will be applied to future tests with a MHD system. Initial experiments will utilize a 50 keV electron gun that can operate at up to a current of 200 micro A. Spreading the electron beam over a four inch diameter window results in an electron flux of 1.5x 10(exp 13) e/sq cm/s. The equivalent neutron flux that would produce the same ionization fraction in helium is 1x10(exp 12) n/sq cm/s. Experiments will simulate the neutron generated plasma modeled by Bitteker, which takes into account the products of thermal neutron absorption in He-3, and includes various ion species in estimating the conductivity of the resulting plasma. Several

  13. Fibre optic control for electron gun power supplies and data acquisition of 3 MeV DC accelerator

    International Nuclear Information System (INIS)

    Chavan, R.B.; Yadav, Vivek; Dixit, K.P.; Bakhtsingh, R.I.; Rajan, Rehim; Nanu, K.; Mittal, K.C.; Chakravarthy, D.P.; Gantayet, L.M.

    2011-01-01

    A 3 MeV, 10 mA DC Industrial Electron Beam Accelerator is being commissioned at Electron Beam Centre, Navi Mumbai. The electron beam is generated by a triode electron gun and injected into the accelerating column at 5 keV. The gun and its power supplies, (5 kV anode, 3 kV grid and 15V/20A filament), are floating at 3 Million volts, and are situated in a tank which is pressurized with SF6 at 6 kg/cm 2 . These power supplies are required to be controlled remotely. The various accelerator parameters like Beam Energy, Beam Current, RF Electrode Voltage, Power Oscillator Plate Voltage / Current and Vacuum are required to be monitored during beam operation. The software was developed in VB.Net for control and data acquisition. The database is provided in SQL 2005 for storing the data. For this purpose, control system using ADAM modules and Optical fibre has been designed and developed. This paper describes the design features of the control system and experience of use of control software during initial beam trials. (author)

  14. Electron-gun Evaporation of Cu and In thin Films as Precursors for CuInSe, Formation

    International Nuclear Information System (INIS)

    Caballero, R.; Guillen, C.

    2001-01-01

    In the present invigorations CuInSe, is obtained in two stages: sequential evaporation of Cu and In using an electron gun evaporator on substrates up to 30 x 30 cm 2 , and a posterior selenization of the deposited films. The study is mainly focused on the first stage, in where the control of the different evaporation parameters of the metal precursors is essential. Electrical measurements are carried out, and also the topography and the thickness are determined with the object of studying the properties and homogeneity of the thin films. (Author) 19 refs

  15. Optimization of beam parameters of electron gun for 2.5 MeV/100 kW high power industrial accelerator

    International Nuclear Information System (INIS)

    Pramod, R.; Petwal, V.C.

    2009-01-01

    A 2.5 MeV/100 kW transformer type industrial accelerator is being developed at RRCAT. A Pierce type electron gun consisting of 10 mm diameter LaB 6 disc (indirectly heated) is used as a source of electron beam. The cathode assembly is put on the top of the accelerating structure, which consists of many electrostatic lenses of which the first lens acts as anode of the gun. The quality of the beam injected into the accelerating structure depends on the anode voltage, shape and size of anode and its distance from the cathode. The anode is subjected to variable voltage during the operation of accelerator from energy 1 MeV to 2.5 MeV, which results in variable emittance at the exit of the electron gun. The electron beam from the gun should provide parallel or slightly convergent beam with long focal length and the emittance of the beam at the exit of electron gun should match the beam acceptance limit of the accelerating structure. The EGUN code is used to optimize the shape and size of the anode, its distance from the cathode to achieve above objectives. Our study suggests that the desired beam parameters at the exit of the anode can be obtained by reducing the aperture size of the anode and by applying suitable voltage gradient to the anode. (author)

  16. Development of high-current-density LAB6 thermionic emitters for a space-charge-limited electron gun

    International Nuclear Information System (INIS)

    Herniter, M.E.; Getty, W.D.

    1987-01-01

    An electron gun has been developed for investigation of high current density, space charge limited operation of a lenthanum hexaboride (LaB 6 ) thermionic cathode. The 2.8 cm 2 cathode disk is heated by electron bombardment from a tungsten filament. For LaB 6 cathode temperatures greater than 1600 0 C it has been found that evaporation from the LaB 6 causes an increase in the tungsten filament emission, leading to an instability in the bombardment heating system. This instability has been investigated and eliminated by using a graphite disk in place of the LaB 6 cathode or by shielding the filament from the LaB 6 cathode by placing the LaB 6 in a graphite cup and bombarding the cup. The graphite disk has been heated to 1755 0 C with 755 W of heating power, and the shielded LaB 6 cathode has been heated to 1695 0 C. This temperature range is required for emission current densities in the 30 Acm 2 range. It is believed that the evaporation of lanthanum lowers the tungsten work function. In electron-gun use, the LaB 6 cathode has been operated up to 6.7 Acm 2 at 36 kV. A 120 kV Marx generator has been built to allow operation up to 40 Acm 2

  17. 120 Hz Gun Review

    Energy Technology Data Exchange (ETDEWEB)

    Colby, E.

    2005-01-31

    The review was held at SLAC on September 11 and 12, 2001. Presentations concerning the thermal analysis, mechanical design, integration with the laser and accelerator, general beam dynamics considerations, a load lock mechanism, and symmetric power feed options comprised the review. Slides from these presentations are available elsewhere. The review committee was charged with evaluating the 120 Hz gun design including proposed load lock and power feed options and recommending improvements. Broader evaluation of the injector as a whole (including focusing and diagnostic systems that do no impact the envelope of the gun itself) is expected to be covered in a future review and will not be commented on here. In general, the long operational experience with four generations of s-band RF guns at numerous labs worldwide has led to considerable experience in design, fabrication, and operation aspects, and provides an excellent base on which to design the higher duty factor LCLS injector. While open questions remain on obtaining the design performance from these injectors, the microwave design of the gun has reached a state of relative maturity.

  18. Gun Safety

    Science.gov (United States)

    Many U.S. households have guns, but they can cause harm if not handled properly. Here are some things you can do to keep yourself and ... safe: Teach children that they shouldn't touch guns and that if they see a gun, to ...

  19. Electron Gun and Collector Design for 94 GHz Gyro-amplifiers.

    Science.gov (United States)

    Nguyen, K.; Danly, B.; Levush, B.; Blank, M.; True, D.; Felch, K.; Borchard, P.

    1997-05-01

    The electrical design of the magnetron injection gun and collector for high average power TE_01 gyro-amplifiers has recently been completed using the EGUN(W.B. Herrmannsfeldt, AIP Conf. Proc. 177, pp. 45-58, 1988.) and DEMEOS(R. True, AIP Conf. Proc. 297, pp. 493-499, 1993.) codes. The gun employs an optimized double-anode geometry and a radical cathode cone angle of 500 to achieve superior beam optics that are relatively insensitive to electrode misalignments and field errors. Perpendicular velocity spread of 1.6% at an perpendicular to axial velocity ratio of 1.52 is obtained for a 6 A, 65 kV beam. The 1.28" diameter collector, which also serves as the output waveguide, has an average power density of < 350 W/cm^2 for a 59 kW average power beam. Details will be presented at the conference.

  20. RF Design of the LCLS Gun

    International Nuclear Information System (INIS)

    Limborg-Deprey, C.

    2010-01-01

    Final dimensions for the LCLS RF gun are described. This gun, referred to as the LCLS gun, is a modified version of the UCLA/BNL/SLAC 1.6 cell S-Band RF gun (1), referred to as the prototype gun. The changes include a larger mode separation (15 MHz for the LCLS gun vs. 3.5 MHz for the prototype gun), a larger radius at the iris between the 2 cells, a reduced surface field on the curvature of the iris between the two cells, Z power coupling, increased cooling channels for operation at 120 Hz, dual rf feed, deformation tuning of the full cell, and field probes in both cells. Temporal shaping of the klystron pulse, to reduce the average power dissipated in the gun, has also been adopted. By increasing the mode separation, the amplitude of the 0-mode electric field on the cathode decreases from 10% of the peak on axis field for the prototype gun to less than 3% for the LCLS gun for the steady state fields. Beam performance is improved as shown by the PARMELA simulations. The gun should be designed to accept a future load lock system. Modifications follow the recommendations of our RF review committee (2). Files and reference documents are compiled in Section IV.

  1. Dark current studies on a normal-conducting high-brightness very-high-frequency electron gun operating in continuous wave mode

    Directory of Open Access Journals (Sweden)

    R. Huang

    2015-01-01

    Full Text Available We report on measurements and analysis of a field-emitted electron current in the very-high-frequency (VHF gun, a room temperature rf gun operating at high field and continuous wave (CW mode at the Lawrence Berkeley National Laboratory (LBNL. The VHF gun is the core of the Advanced Photo-injector Experiment (APEX at LBNL, geared toward the development of an injector for driving the next generation of high average power x-ray free electron lasers. High accelerating fields at the cathode are necessary for the high-brightness performance of an electron gun. When coupled with CW operation, such fields can generate a significant amount of field-emitted electrons that can be transported downstream the accelerator forming the so-called “dark current.” Elevated levels of a dark current can cause radiation damage, increase the heat load in the downstream cryogenic systems, and ultimately limit the overall performance and reliability of the facility. We performed systematic measurements that allowed us to characterize the field emission from the VHF gun, determine the location of the main emitters, and define an effective strategy to reduce and control the level of dark current at APEX. Furthermore, the energy spectra of isolated sources have been measured. A simple model for energy data analysis was developed that allows one to extract information on the emitter from a single energy distribution measurement.

  2. Uranium sandwich targets of 0.1 to 100 mg.cm-2 prepared by electron beam gun evaporation

    International Nuclear Information System (INIS)

    Folger, H.; Klemm, J.

    1978-01-01

    Metallic uranium layers of 0.1 to 100 mg.cm -2 between different backings and protecting layers were prepared for bombardments with heavy ions such as argon, krypton, xenon, lead, or uranium at energies of up to 8 MeV/u at the UNILAC of the GSI. An experimental set-up for the preparation of thick and oxygen-free sandwich targets using a 6 kVA electron beam gun was installed in a high vacuum apparatus. Then deposition and evaporation rates for uranium were investigated as a function of the electron beam gun power. It turned out that reproducible evaporation rates of up to 7 mg.s -1 were achieved when uranium pieces of 20 to 40 grams were used. Specific evaporation rates and vapor pressures for different temperatures were calculated. Some of these data are compared to measured values, especially evaporation rates at the evaporation point. The preparation, composition, and usage of uranium sandwich targets is described in detail. It concerns uranium layers of 0.1 to 100 mg.cm -2 deposited onto backings of carbon, titanium, nickel, gold, or glass. Evaporated films of carbon, titanium, nickel, or gold of 0.01 to 0.2 mg.cm -2 are used to protect the uranium layers from oxidation

  3. High-power test of S-band klystron for long-pulse operation

    International Nuclear Information System (INIS)

    Morii, Y.; Oshita, E.; Abe, S.; Keishi, T.; Tomimasu, T.; Ohkubo, Y.; Yoshinao, M.; Yonezawa, H.

    1994-01-01

    FELI(Free Electron Laser Research Institute, Inc.) is constructing a free electron laser facility covering from 20μm (infra red region) to 0.35μm (ultra violet region), using an S-band linac. The linac is commissioning now. An RF system of the linac for FELs is required of long pulse duration and high stability. S-band klystrons (TOSHIBA E3729) of the FELI linac are operated in three pulse operation modes (pulse width and peak RF power; 24μs-24MW, 12.5μs-34MW, 0.5μs-70MW). The S-band klystron and its modulator were combined to test their performance. The high power test results of the S-band klystron are summarized in this paper. (author)

  4. Electron beam welding of heavy thicknesses with a 200 KW gun

    International Nuclear Information System (INIS)

    Binard, J.; Ducrot, A.

    1986-09-01

    In this report, we describe our 200 kW gun, 100 m 3 vacuum chamber E B welding equipment, implemented since 1985 to increase the process development in the heavy mechanics; to score the goal, we study the influence of parameters as: welding positions, chemical analysis of the material and workpiece thickness. Simultaneously, we carry out welding tests of branch pipes or nozzles on tubes and shells. Some results are shown and good mechanical properties are obtained on thicknesses up to 300 mm

  5. Results of the SLAC LCLS Gun High-Power RF Tests

    International Nuclear Information System (INIS)

    Dowell, D.H.; Jongewaard, E.; Limborg-Deprey, C.; Schmerge, J.F.; Li, Z.; Xiao, L.; Wang, J.; Lewandowski, J.; Vlieks, A.

    2007-01-01

    The beam quality and operational requirements for the Linac Coherent Light Source (LCLS) currently being constructed at SLAC are exceptional, requiring the design of a new RF photocathode gun for the electron source. Based on operational experience at SLAC's GTF and SDL and ATF at BNL as well as other laboratories, the 1.6cell s-band (2856MHz) gun was chosen to be the best electron source for the LCLS, however a significant redesign was necessary to achieve the challenging parameters. Detailed 3-D analysis and design was used to produce near-perfect rotationally symmetric rf fields to achieve the emittance requirement. In addition, the thermo-mechanical design allows the gun to operate at 120Hz and a 140MV/m cathode field, or to an average power dissipation of 4kW. Both average and pulsed heating issues are addressed in the LCLS gun design. The first LCLS gun is now fabricated and has been operated with high-power RF. The results of these high-power tests are presented and discussed

  6. Ultra-High Gradient S-band Linac for Laboratory and Industrial Applications

    Science.gov (United States)

    Faillace, L.; Agustsson, R.; Dolgashev, V.; Frigola, P.; Murokh, A.; Rosenzweig, J.; Yakimenko, V.

    2010-11-01

    A strong demand for high gradient structures arises from the limited real estate available for linear accelerators. RadiaBeam Technologies is developing a Doubled Energy Compact Accelerator (DECA) structure: an S-band standing wave electron linac designed to operate at accelerating gradients of up to 50 MV/m. In this paper, we present the radio-frequency design of the DECA S-band accelerating structure, operating at 2.856 GHz in the π-mode. The structure design is heavily influenced by NLC collaboration experience with ultra high gradient X-band structures; S-band, however, is chosen to take advantage of commonly available high power S-band klystrons.

  7. Gun Safety (For Kids)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Gun Safety KidsHealth / For Kids / Gun Safety What's in ... from guns outside the home. If You Have Guns in Your Home If your parents keep guns ...

  8. Sanoli Gun

    Indian Academy of Sciences (India)

    Home; Journals; Proceedings – Mathematical Sciences. Sanoli Gun. Articles written in Proceedings – Mathematical Sciences. Volume 119 Issue 3 June 2009 pp 275-281. Remarks on some Zero-Sum Theorems · S D Adhikari Sanoli Gun Purusottam Rath · More Details Abstract Fulltext PDF. In the present paper, we give a ...

  9. Emittance studies of the BNL/SLAC/UCLA 1.6 cell photocathode rf gun

    International Nuclear Information System (INIS)

    Palmer, D.T.; Miller, R.H.; Wang, X.J.

    1997-01-01

    The symmetrized 1.6 cell S-band photocathode gun developed by the BNL/SLAC/UCLA collaboration is in operation at the Brookhaven Accelerator Test Facility (ATF). A novel emittance compensation solenoid magnet has also been designed, built and is in operation at the ATF. These two subsystems form an emittance compensated photoinjector used for beam dynamics, advanced acceleration and free electron laser experiments at the ATF. The highest acceleration field achieved on the copper cathode is 150 MV/m, and the guns normal operating field is 130 MV/m. The maximum rf pulse length is 3 micros. The transverse emittance of the photoelectron beam were measured for various injection parameters. The 1 nC emittance results are presented along with electron bunch length measurements that indicated that at above the 400 pC, space charge bunch lengthening is occurring. The thermal emittance, ε o , of the copper cathode has been measured

  10. IHEP S-band 45 MW pulse power klystron development

    International Nuclear Information System (INIS)

    Dong Dong; Zhou Zusheng; Zhang Liang; Li Gangying; Tian Shuangmin

    2006-01-01

    S-band 45 MW pulse power klystron has been developed in the Institute of High Energy Physics (IHEP) for the Beijing Electron Positron Collider (BEPC) upgrade projects (BEPC-II). This new klystron has 5 cavities in its RF-beam interaction and single RF output window, and the RF output power is 45 MW at 310 kV, the gain is 50 dB, the efficiency 40%. The manufacturing, training and testing of a prototype klystron has been finished in IHEP and RF power 45 MW at 300 kV has been reached. The testing results show that all the parameters of the 45 MW klystron reach the design goal. (authors)

  11. Examination of the spatial-response uniformity of a microchannel-plate detector using a pulsed high-voltage electron gun

    International Nuclear Information System (INIS)

    Alumot, D; Kroupp, E; Fisher, A

    2014-01-01

    In this paper we describe an alternative method to examine the spatial-response uniformity of a microchannel-plate (MCP) detector to a ∼ 1 ns pulse of soft x-rays. The examination was performed by illuminating the MCP surface with energetic electrons rather than with x-rays. It is shown that the MCP features similar, yet not identical, response to pulses of soft x-ray photons or energetic electrons, making such examinations much simpler and less expensive. The building of the electron-gun system is relatively easy and inexpensive, and in addition to verifying the spatial uniformity of the response of the MCP to incoming particles and radiation, it can be used to detect damaged areas on the detector. A comparison between the results obtained using the electron-gun with those obtained using a laser-produced-plasma x-ray source, demonstrating the reliability of the method, is presented

  12. Excitation of plasma waves by electron guns at the ISEE-1 satellite

    International Nuclear Information System (INIS)

    Lebreton, Zh.P.; Torbert, R.; Anderson, R.; Kharvi, K.

    1985-01-01

    Study of the effects resulting from excitation of plasma waves by electron beams injected from JSEE-1 satellite is carried out. Cases of the satellite traversing the magnetosphere magnetosheath and solar wind are considered. 10-60 μA and 0-40 V electron beam injection from the satellite increased electrostatic waves spectral intensity. The waves below ionic plasma frequency are interpreted as ion acoustic waves. To explain the-above-electron-plasma-frequency wave oscillation a communication system between electron plasma mode and electron flux with the velocities above the mean thermal velocity of plasma cold electrons is suggested

  13. TU-H-BRA-03: Performance of a Clinical Gridded Electron Gun in Magnetic Fields: Implications for MRI-Linac Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Whelan, B; Keall, P [University of Sydney, Sydney (Australia); Bazalova-Carter, M [University of Victoria, VCH040, Victoria, BC (Australia); Oborn, B [Illawarra Hospital, Wollongong, NSW (Australia); Constantin, D [Varian Medical Systems, Palo Alto, California (United States); Holloway, L [Liverpool Hospital and Ingham Institute, Liverpool, NSW (United Kingdom); Fahrig, R [Siemens Healthcare GmbH, Forchheim (Germany)

    2016-06-15

    Purpose: Recent advances towards MRI Linac radiotherapy have motivated a wide range of studies characterizing electromagnetic interactions between the two devices. One of the most sensitive components is the linac electron gun. To data, only non gridded (diode) guns have been investigated however, most linac vendors utilize gridded (triode) guns, which enable efficient and robust beam gating. The purpose of this study was to develop a realistic model of a gridded gun used clinically, and to characterize its performance in magnetic fields. Methods: The gridded electron gun used on Varian high energy machines was measured using 3D laser scanning quoted as accurate to 0.1mm. Based on the scane, a detailed CAD mode was developed. From this, key geometry was extracted and a FEM model was developed (Opera/SCALA). Next, the high voltage (HV), grid voltage, and emission current were read from six dose matched TrueBeam linacs for the 6X, 10X and 15X photon modes (0 B-field). The mean values were used to represent each mode, which was simulated I constant magnetic fields from 0–200G in-line, and 0–35G perpendicular. Results: Experimentally measured HV, grid voltage, and emission current from 6X, 10X and 15X modes were respectively: 15±.03kV, 10±.08kV, 11±.03kV; 93±7V, 41±3V, and 70±6V; 327±27mA, 129±10mA, and 214±19mA. The error in simulated emission current of each mode was 3%,6%, and 3%. For in-line fields, 50% beam loss occurred at 114, 96, and 97G; for perpendicular; at 12, 13 and 14G. Sensitivity for a given geometry is primarily determined by HV setting. Conclusion: Future MRI-Linac systems will almost certainly use gridded guns. We present the first model of a clinical gridded gun, and match the experimental emission current to within 6% across three different operating modes. This clinical gun shows increased sensitivity to magnetic fields than previous work,and different modes show different sensitivity.

  14. TU-H-BRA-03: Performance of a Clinical Gridded Electron Gun in Magnetic Fields: Implications for MRI-Linac Therapy

    International Nuclear Information System (INIS)

    Whelan, B; Keall, P; Bazalova-Carter, M; Oborn, B; Constantin, D; Holloway, L; Fahrig, R

    2016-01-01

    Purpose: Recent advances towards MRI Linac radiotherapy have motivated a wide range of studies characterizing electromagnetic interactions between the two devices. One of the most sensitive components is the linac electron gun. To data, only non gridded (diode) guns have been investigated however, most linac vendors utilize gridded (triode) guns, which enable efficient and robust beam gating. The purpose of this study was to develop a realistic model of a gridded gun used clinically, and to characterize its performance in magnetic fields. Methods: The gridded electron gun used on Varian high energy machines was measured using 3D laser scanning quoted as accurate to 0.1mm. Based on the scane, a detailed CAD mode was developed. From this, key geometry was extracted and a FEM model was developed (Opera/SCALA). Next, the high voltage (HV), grid voltage, and emission current were read from six dose matched TrueBeam linacs for the 6X, 10X and 15X photon modes (0 B-field). The mean values were used to represent each mode, which was simulated I constant magnetic fields from 0–200G in-line, and 0–35G perpendicular. Results: Experimentally measured HV, grid voltage, and emission current from 6X, 10X and 15X modes were respectively: 15±.03kV, 10±.08kV, 11±.03kV; 93±7V, 41±3V, and 70±6V; 327±27mA, 129±10mA, and 214±19mA. The error in simulated emission current of each mode was 3%,6%, and 3%. For in-line fields, 50% beam loss occurred at 114, 96, and 97G; for perpendicular; at 12, 13 and 14G. Sensitivity for a given geometry is primarily determined by HV setting. Conclusion: Future MRI-Linac systems will almost certainly use gridded guns. We present the first model of a clinical gridded gun, and match the experimental emission current to within 6% across three different operating modes. This clinical gun shows increased sensitivity to magnetic fields than previous work,and different modes show different sensitivity.

  15. SLAC collider injector, RF-drive synchronization and trigger electronics, and 15-AMP thermionic-gun development

    International Nuclear Information System (INIS)

    Koontz, R.; Miller, R.; McKinney, T.; Wilmunder, A.

    1981-02-01

    The rf drive system for the Collider Injector Development (EL CID) including laser timing, subharmonic buncher drive and phasing, and accelerator rf drive is described. The rf synchronized master trigger generation scheme for the collider is outlined. Also, a 15 amp peak, 200 kV short pulse gun being developed at SLAC as a backup to the Sinclair laser gun is described

  16. THz and Sub-THz Capabilities of a Table-Top Radiation Source Driven by an RF Thermionic Electron Gun

    Energy Technology Data Exchange (ETDEWEB)

    Smirnov, Alexei V.; Agustsson, R.; Boucher, S.; Campese, Tara; Chen, Y.C.; Hartzell, Josiah J.; Jocobson, B.T.; Murokh, A.; O' Shea, F.H.; Spranza, E.; Berg, W.; Borland, M.; Dooling, J. C.; Erwin, L.; Lindberg, R. R.; Pasky, S.J.; Sereno, N.; Sun, Y.; Zholents, A.

    2017-06-01

    Design features and experimental results are presented for a sub-mm wave source [1] based on APS RF thermionic electron gun. The setup includes compact alpha-magnet, quadrupoles, sub-mm-wave radiators, and THz optics. The sub-THz radiator is a planar, oversized structure with gratings. Source upgrade for generation frequencies above 1 THz is discussed. The THz radiator will use a short-period undulator having 1 T field amplitude, ~20 cm length, and integrated with a low-loss oversized waveguide. Both radiators are integrated with a miniature horn antenna and a small ~90°-degree in-vacuum bending magnet. The electron beamline is designed to operate different modes including conversion to a flat beam interacting efficiently with the radiator. The source can be used for cancer diagnostics, surface defectoscopy, and non-destructive testing. Sub-THz experiment demonstrated a good potential of a robust, table-top system for generation of a narrow bandwidth THz radiation. This setup can be considered as a prototype of a compact, laser-free, flexible source capable of generation of long trains of Sub-THz and THz pulses with repetition rates not available with laser-driven sources.

  17. Stimulation of plasma waves by electron guns on the ISEE-1 satellite

    Science.gov (United States)

    Lebreton, J.-P.; Torbert, R.; Anderson, R.; Harvey, C.

    1982-01-01

    The results of the ISEE-1 satellite experiment relating to observations of the waves stimulated during electron injections, when the spacecraft is passing through the magnetosphere, the magnetosheath, and the solar wind, are discussed. It is shown that the injection of an electron beam current of the order of 10 to 60 microamperes with energies ranging from 0 to 40 eV produces enhancements in the electric wave spectrum. An attempt has been made to identify the low-frequency electrostatic wave observed below the ion plasma frequency as an ion acoustic mode, although the excitation mechanism is not clear. A coupling mechanism between the electron plasma mode and streaming electrons with energies higher than the thermal speed of the cold electron population has been proposed to explain the observations above the electron plasma frequency.

  18. Stimulation of plasma waves by electron guns on the ISEE-1 satellite

    International Nuclear Information System (INIS)

    Lebreton, J.P.; Torbert, R.; Anderson, R.; Harvey, C.

    1982-01-01

    The results of the ISEE-1 satellite experiment relating to observations of the waves stimulated during electron injections, when the spacecraft is passing through the magnetosphere, the magnetosheath, and the solar wind, are discussed. It is shown that the injection of an electron beam current of the order of 10 to 60 microamperes with energies ranging from 0 to 40 eV produces enhancements in the electric wave spectrum. An attempt has been made to identify the low-frequency electrostatic wave observed below the ion plasma frequency as an ion acoustic mode, although the excitation mechanism is not clear. A coupling mechanism between the electron plasma mode and streaming electrons with energies higher than the thermal speed of the cold electron population has been proposed to explain the observations above the electron plasma frequency. 9 references

  19. Pilot study of synchronization on a femtosecond scale between the electronic gun REGAE and a laser-plasma accelerator

    International Nuclear Information System (INIS)

    Titberidze, Mikheil

    2017-10-01

    Laser wakefield acceleration (LWFA) is a novel technique to accelerate charged particles. Acceleration is achieved by a high-power laser pulse transmitting a gas target where electrons and ions form a strong wakefield with gradients up to 100 GVm -1 . Hence, the size of the laser-plasma accelerator (LPA) is significantly smaller compared to conventional radio frequency (RF) accelerators, because its accelerating gradients are 3 orders of magnitude higher. At present, electron beams generated by LWFA do not satisfy all requirements to make them directly usable for applications such as LPA driven free-electron laser (FEL). Pointing stability and relatively high energy spread are the major limiting factors. Typically, plasma electrons are self-injected in the plasma wake which is created by a high-power laser. There is a lack of control for the injection process and there is no direct access for diagnostics. In order to overcome these challenges and better understand the overall LWFA process, external injection experiments are planned at Deutsches Elektronen-Synchrotron (DESY) in the framework of the Laboratory for Laser and beam-driven plasma Acceleration (LAOLA) collaboration. Thus, well characterized and ultrashort (< 10 fs) electron bunches from the conventional RF accelerator Relativistic Electron Gun for Atomic Exploration (REGAE) will be injected into the laser driven plasma wake. This approach allows to reconstruct and map the plasma wakefield by post diagnosing the injected electron bunches by measuring the energy spectra of it for different injection times. To conduct such a pump-probe type of experiment, synchronization with fs accuracy is required between the electron bunches from REGAE and the high-power driver laser. Two main aspects of the laser synchronization are presented in this thesis. First, a detailed experimental investigation of the conventional, fast photodiode based direct conversion laser-to-RF synchronization setup and its limitations are

  20. Pilot study of synchronization on a femtosecond scale between the electronic gun REGAE and a laser-plasma accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Titberidze, Mikheil

    2017-10-15

    Laser wakefield acceleration (LWFA) is a novel technique to accelerate charged particles. Acceleration is achieved by a high-power laser pulse transmitting a gas target where electrons and ions form a strong wakefield with gradients up to 100 GVm{sup -1}. Hence, the size of the laser-plasma accelerator (LPA) is significantly smaller compared to conventional radio frequency (RF) accelerators, because its accelerating gradients are 3 orders of magnitude higher. At present, electron beams generated by LWFA do not satisfy all requirements to make them directly usable for applications such as LPA driven free-electron laser (FEL). Pointing stability and relatively high energy spread are the major limiting factors. Typically, plasma electrons are self-injected in the plasma wake which is created by a high-power laser. There is a lack of control for the injection process and there is no direct access for diagnostics. In order to overcome these challenges and better understand the overall LWFA process, external injection experiments are planned at Deutsches Elektronen-Synchrotron (DESY) in the framework of the Laboratory for Laser and beam-driven plasma Acceleration (LAOLA) collaboration. Thus, well characterized and ultrashort (< 10 fs) electron bunches from the conventional RF accelerator Relativistic Electron Gun for Atomic Exploration (REGAE) will be injected into the laser driven plasma wake. This approach allows to reconstruct and map the plasma wakefield by post diagnosing the injected electron bunches by measuring the energy spectra of it for different injection times. To conduct such a pump-probe type of experiment, synchronization with fs accuracy is required between the electron bunches from REGAE and the high-power driver laser. Two main aspects of the laser synchronization are presented in this thesis. First, a detailed experimental investigation of the conventional, fast photodiode based direct conversion laser-to-RF synchronization setup and its limitations

  1. Initial Beam Dynamics Simulations of a High-Average-Current Field-Emission Electron Source in a Superconducting RadioFrequency Gun

    Energy Technology Data Exchange (ETDEWEB)

    Mohsen, O. [Northern Illinois U.; Gonin, I. [Fermilab; Kephart, R. [Fermilab; Khabiboulline, T. [Fermilab; Piot, P. [Northern Illinois U.; Solyak, N. [Fermilab; Thangaraj, J. C. [Fermilab; Yakovlev, V. [Fermilab

    2018-01-05

    High-power electron beams are sought-after tools in support to a wide array of societal applications. This paper investigates the production of high-power electron beams by combining a high-current field-emission electron source to a superconducting radio-frequency (SRF) cavity. We especially carry out beam-dynamics simulations that demonstrate the viability of the scheme to form $\\sim$ 300 kW average-power electron beam using a 1+1/2-cell SRF gun.

  2. Gun Control, Gun Ownership, and Suicide Prevention.

    Science.gov (United States)

    Lester, David

    1988-01-01

    Explored relationship between the extent of gun ownership and the strictness of gun control laws to suicide and homicide rates in the nine major geographic regions of the United States. Found gun ownership, rather than the strictness of gun control laws, was the strongest correlate of the rates of suicide and homicide by guns. (Author)

  3. Transverse Laser Beam Shaping in High Brightness Electron Gun at ATF

    CERN Document Server

    Roychowdhury, S

    2005-01-01

    The brightness of electron beams from a photo injector is influenced by the transverse and longitudinal distribution of the laser beam illuminating the cathode. Previous studies at Brookhaven Accelerator Test Facility have shown that formation of an ideal e-beam with lowest transverse emittance requires uniform circular distribution of the emitted electrons. The use of the uniformly distributed power of the laser beam may not lead to that of the emitted electrons because of the non-uniform quantum efficiency. A proper shaping of the laser beam can compensate for this non-uniformity. In this paper we describe the use of digital light processing (DLP) technique based on digital mirror device (DMD) for spatial modulation of the laser beam, for measurements of the quantum efficiency map, and for creating the desirable e-beam density profiles. A DMD is aμelectronic mechanical system (MEMS) comprising of millions of highly reflectiveμmirrors controlled by underlying electronics. We present exper...

  4. Development, construction and characterization of a variable repetitive spin-polarized electron gun with an inverted-geometry insulator

    International Nuclear Information System (INIS)

    Espig, Martin

    2016-02-01

    Within the scope of this thesis a pulsed source of spin polarized electrons Photo-CATCH was designed, constructed, characterized and has been put into operation. This source is based on the photoemission of spin-polarized electrons from GaAs-photocathodes. Both the design of the electron gun, consisting of an ultra-high vacuum chamber and an electrode with Pierce geometry, as well as the properties of the electron beam have been simulated with CST Studio. Results were a maximum electric field of (0.064±0.001) MV/m/kV on the electrode surface and a beam emittance as a function of the radius of the laser spot on the photocathode of element of _n_,_x=(1.7478(4).10"-"4.(r)/(μm)+2.8(18).10"-"5) mm mrad at a beam current of 100 μA. Currently Photo-CATCH provides electron beams with an energy of 60 keV, which can be expanded up to 100 keV by upgrading the high-voltage power supply. The electron gun has an inverted-geometry insulator to ensure a compact design of the ultra-high vacuum chamber and a maximum person- and machine-safety from sparkovers. Since the properties of the laser light directly affect the properties of the generated electron beam a pulsed semiconductor laser system has been specially developed and built for Photo-CATCH. This is characterized by a high variability of its operating parameters, in particular its wavelength and repetition rate, in order to fulfill the broad variety of requirements of various nuclear physics experiments. By selecting the wavelength of the used laser diode highly polarized or high-current electron beams can be generated from GaAs-photocathodes. The time profile of the laser has direct influence to the longitudinal profile of the electron bunch. Through the radiofrequency modulation of the pumping current of the impedance-matched semiconductor laser system, consisting of a DC power source and an electrical pulse generator with 881 ps broad pump pulses, Lorentz shaped laser pulses with a minimum FWHM of (43.8±1.2) ps at a

  5. Beam Characterizations at Femtosecond Electron Beam Facility

    CERN Document Server

    Rimjaem, Sakhorn; Kangrang, Nopadol; Kusoljariyakul, Keerati; Rhodes, Michael W; Saisut, Jatuporn; Thongbai, Chitrlada; Vilaithong, Thiraphat; Wichaisirimongkol, Pathom; Wiedemann, Helmut

    2005-01-01

    The SURIYA project at the Fast Neutron Research Facility (FNRF) has been established and is being commissioning to generate femtosecond electron pulses. Theses short pulses are produced by a system consisting of an S-band thermionic cathode RF-gun, an alpha magnet as a magnetic bunch compressor, and a linear accelerator. The characteristics of its major components and the beam characterizations as well as the preliminary experimental results will be presented and discussed.

  6. Impulse electron gun with plasma cathode for realization of large diameter tube-shaped beams

    International Nuclear Information System (INIS)

    Antipov, V.S.; Karpukhin, V.I.; Kornilov, E.A.

    1999-01-01

    There are presented the results of investigations of a plasma electron source based on the gas discharge in a coaxial system of electrodes with longitudinal magnetic field. The examination is fulfilled from the viewpoint of applying the source as a plasma cathode for hybrid plasma-waveguide slow-wave structures on the basis of a disk-loaded coaxial. The source is optimized in order to get a powerful (up to 100 kW) nonrelativistic electron beam with the annular cross-section of a large diameter in the regime of relatively long current pulses (up to 0.2 ms) under the gas pressure ∼ 5 centre dot 10 -4 mm Hg in the area of the discharge burning

  7. High Efficiency S-Band 20 Watt Amplifier

    Data.gov (United States)

    National Aeronautics and Space Administration — This project includes the design and build of a prototype 20 W, high efficiency, S-Band amplifier.   The design will incorporate the latest semiconductor technology,...

  8. Analysis of microwave amplifier and frequency multiplier tube with a multipactor electron gun

    International Nuclear Information System (INIS)

    Yokoo, Kuniyoshi; Ono, Shoichi; Tai, Dong-Zhe.

    1983-01-01

    The performance analysis was made for a multipactor microwave tube with the aim of realizing a microwave amplifier or a frequency multiplier tube with a multipactor cathode with high efficiency and high power. The possibility for producing the multipactor tube with high efficiency and high power was shown by using effectively the characteristics of the multipactor cathode which emits pulsed electron current with narrow band, synchronizing with high frequency period. As the operating conditions for the multipactor cathode, it was shown that the wide spacing of the cathode was needed for the operation in high operating power, and the narrow spacing was needed for the operation in high efficiency and for reducing power consumption. It was also shown that there were the best values of the high-frequency voltage for the cathode operation. The study by the simulation for the multipactor cathode and for the acceleration zone of electron current was also performed to examine the possible performance for a microwave amplifier and a frequency multiplier tube. For the use of the multipactor cathode with a spacing of 1 mm, the conversion efficiency for d. c. input power was 86, 56 and 31 % for the primary, the secondary and the tertiary harmonic wave amplifications, respectively. (Asami, T.)

  9. Magnetron based high energy S-band linac system

    International Nuclear Information System (INIS)

    Tiwari, T.; Krishnan, R.; Phatangare, Manoj

    2012-01-01

    This paper deals with the study of magnetron based high energy S-band linear accelerator (linac) system operating at spot frequency 2.998 GHz. The energy and dose are two important parameters of linac system which depend on input power of microwave source and length of linac tube. Here the author has studied how these parameters can be improved for side coupled standing wave S-band linac system

  10. Spectrometer gun

    Science.gov (United States)

    Waechter, David A.; Wolf, Michael A.; Umbarger, C. John

    1985-01-01

    A hand-holdable, battery-operated, microprocessor-based spectrometer gun includes a low-power matrix display and sufficient memory to permit both real-time observation and extended analysis of detected radiation pulses. Universality of the incorporated signal processing circuitry permits operation with various detectors having differing pulse detection and sensitivity parameters.

  11. Characterization of a Carbon Nanotube Field Emission Electron Gun for the VAPoR Miniaturized Pyrolysis-Time-of-Flight Mass Spectrometer

    Science.gov (United States)

    Getty, Stephanie; Li, Mary; Costen, Nicholas; Hess, Larry; Feng, Steve; King, Todd; Brinckerhoff, William; Mahaffy, Paul; Glavin, Daniel

    2009-01-01

    We are developing the VAPoR (Volatile Analysis by Pyrolysis of Regolith) instrument towards studying soil composition, volatiles, and trapped noble gases in the polar regions of the Moon. VAPOR will ingest a soil sample and conduct analysis by pyrolysis and time-of-flight mass spectrometry (ToF-MS). Here, we describe miniaturization efforts within this development, including a carbon nanotube (CNT) field emission electron gun that is under consideration for use as the electron impact ionization source for the ToF-MS.

  12. STREAK CAMERA MEASUREMENTS OF THE APS PC GUN DRIVE LASER

    Energy Technology Data Exchange (ETDEWEB)

    Dooling, J. C.; Lumpkin, A. H.

    2017-06-25

    We report recent pulse-duration measurements of the APS PC Gun drive laser at both second harmonic and fourth harmonic wavelengths. The drive laser is a Nd:Glass-based chirped pulsed amplifier (CPA) operating at an IR wavelength of 1053 nm, twice frequency-doubled to obtain UV output for the gun. A Hamamatsu C5680 streak camera and an M5675 synchroscan unit are used for these measurements; the synchroscan unit is tuned to 119 MHz, the 24th subharmonic of the linac s-band operating frequency. Calibration is accomplished both electronically and optically. Electronic calibration utilizes a programmable delay line in the 119 MHz rf path. The optical delay uses an etalon with known spacing between reflecting surfaces and is coated for the visible, SH wavelength. IR pulse duration is monitored with an autocorrelator. Fitting the streak camera image projected profiles with Gaussians, UV rms pulse durations are found to vary from 2.1 ps to 3.5 ps as the IR varies from 2.2 ps to 5.2 ps.

  13. Water gun vs air gun: A comparison

    Science.gov (United States)

    Hutchinson, D.R.; Detrick, R. S.

    1984-01-01

    The water gun is a relatively new marine seismic sound source that produces an acoustic signal by an implosive rather than explosive mechanism. A comparison of the source characteristics of two different-sized water guns with those of conventional air guns shows the the water gun signature is cleaner and much shorter than that of a comparable-sized air gun: about 60-100 milliseconds (ms) for an 80-in3. (1.31-liter (I)) water gun compared with several hundred ms for an 80-in3. (1.31-1) air gun. The source spectra of water guns are richer in high frequencies (>200 Hz) than are those of air guns, but they also have less energy than those of air guns at low frequencies. A comparison between water gun and air gun reflection profiles in both shallow (Long Island Sound)-and deep (western Bermuda Rise)-water settings suggests that the water gun offers a good compromise between very high resolution, limited penetration systems (e.g. 3.5-kHz profilers and sparkers) and the large volume air guns and tuned air gun arrays generally used where significant penetration is required. ?? 1984 D. Reidel Publishing Company.

  14. The design and performance of 150-MW S-band klystrons

    International Nuclear Information System (INIS)

    Sprehn, D.; Phillips, R.M.; Caryotakis, G.

    1994-09-01

    As part of an international collaboration, the Stanford Linear Accelerator Center (SLAC) klystron group has designed, fabricated and tested a 60 Hz, 3 μs, 150 MW klystron built for Deutsches Elektronen Synchrotron (DESY). A test diode with a 535 kV, 700 A electron beam was constructed to verify the gun operation. The first klystron was built and successfully met design specifications. This paper discusses design issues and experimental results of the diode and klystron including the suppression of gun oscillations

  15. The design of gridded pierce guns for accelerators

    International Nuclear Information System (INIS)

    True, R.

    1985-01-01

    It is vital to employ ultra-laminar beams in electron linacs to maximize charge transport to the target. This paper presents numerical and experimental design techniques which have led to significant improvements in gridded Pierce guns used in microwave tubes and electron linacs. The paper concludes with two gun/injector concepts which have demonstrated enhanced performance over standard triode Pierce guns

  16. Simple gun for vapor deposition of organic thin films

    International Nuclear Information System (INIS)

    Sato, N.; Seki, K.; Inokuchi, H.

    1987-01-01

    A simple evaporation gun for preparing organic thin films was fabricated using commercially available parts of an electron gun for a TV Braun tube. The device permits sample heating to be easily controlled because of the small heat capacity

  17. Influence of laser parameters on the relativistic short electron bunches dynamics in linear accelerators based on RF-guns and development of associated diagnostics

    International Nuclear Information System (INIS)

    Vinatier, T.

    2015-01-01

    My thesis investigates dynamics and diagnostics related to short electron bunches, namely whose rms duration is not directly measurable by an electronic method locating the border at a few tens of picoseconds. The short nature of the bunch and the necessity of a high peak current for the applications imply strong space-charge forces leading to a degradation of beam properties, as its transverse emittance and duration. The main difficulty is to characterize, model and take into account these effects. The chapter 2 consists in the measurements of several properties of these bunches: charge, transverse emittance, energy and duration. The originality of my work is that I use simple methods, both on the theoretical (analytical at maximum) and technological (using only common elements of electron accelerators) point of view. I have developed a method of charge measurement from the measurement of the light intensity emitted by a scintillating screen following the interaction with an electron beam. I have also developed a method to measure the bunch mean energy with a steering magnet and a scintillating screen, via the displacement of the bunch centroid as a function of the field of the steering magnet. I have also adapted multi-parametric methods to measure the transverse emittance and duration of electron bunches. These indirect methods allow the determination of these properties from the measurement of other more accessible properties: the transverse dimensions for the transverse emittance and the energy spread for the duration. The chapter 3 consists in the comparison of the properties of short electron beams, single or longitudinally modulated, generated by 3 different methods: Injection of a short or longitudinally modulated laser pulse in an RF-gun; Magnetic compression in a chicane; and RF-compression in an accelerating structure (Velocity Bunching). I have shown that, at equal conditions of charge, the generation of short bunches thanks to a short laser pulse

  18. Simulation study of the high intensity S-Band photoinjector

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Xiongwei; Nakajima, Kazuhisa [High Energy Accelerator Research Organization, Tsukuba, Ibaraki (Japan)

    2001-10-01

    In this paper, we report the results of simulation study of the high intensity S-Band photoinjector. The aim of the simulation study is to transport high bunch charge with low emittance evolution. The simulation result shows that 7nC bunch with rms emittance 22.3 {pi} mm mrad can be outputted at the exit of photoinjector. (author)

  19. Simulation study of the high intensity S-Band photoinjector

    International Nuclear Information System (INIS)

    Zhu, Xiongwei; Nakajima, Kazuhisa

    2001-01-01

    In this paper, we report the results of simulation study of the high intensity S-Band photoinjector. The aim of the simulation study is to transport high bunch charge with low emittance evolution. The simulation result shows that 7nC bunch with rms emittance 22.3 π mm mrad can be outputted at the exit of photoinjector. (author)

  20. RF Gun Optimization Study

    International Nuclear Information System (INIS)

    Alicia Hofler; Pavel Evtushenko

    2007-01-01

    Injector gun design is an iterative process where the designer optimizes a few nonlinearly interdependent beam parameters to achieve the required beam quality for a particle accelerator. Few tools exist to automate the optimization process and thoroughly explore the parameter space. The challenging beam requirements of new accelerator applications such as light sources and electron cooling devices drive the development of RF and SRF photo injectors. A genetic algorithm (GA) has been successfully used to optimize DC photo injector designs at Cornell University [1] and Jefferson Lab [2]. We propose to apply GA techniques to the design of RF and SRF gun injectors. In this paper, we report on the initial phase of the study where we model and optimize a system that has been benchmarked with beam measurements and simulation

  1. Lasers for RF guns: Proceedings

    International Nuclear Information System (INIS)

    Srinivasan-Rao, T.

    1994-01-01

    In the past decade, laser driven RF guns have matured from a device under development to a proven source for high brightness and low emittance electron beams. The reliability of the electron beam from these sources is dictated by the laser system that drives it. In addition, capabilities of the laser systems play a vital role in the design of the electron source for future machines such as the TESLA and NLC. The purpose of this workshop was to provide a forum for discussing the design criteria for the laser systems so that the reliability of the existing sources could be improved and the future machines could be serviced. The Workshop brought together experts in RF Guns, accelerators, and lasers, from both the commercial and academic community. Most of the presentations, discussions and conclusions at the workshop are included in these proceedings. The contents are divided into three sections, Section I contains the invited talks that outline the requirements of the RF Guns and the capabilities of the laser systems to meet these requirements. Section II includes most of the papers presented in the poster session. These papers describe various laser systems used with electron guns, schemes to modify the laser beam profile to optimize the electron bunch, and computer simulations of electron trajectories. Section III contains the summaries of the working groups. As the summary section indicates, with sufficient feed back systems, the electron gun could be made to operate reliably with minimum downtime, using commercial lasers currently available. The design of laser systems for future colliders depend critically on the choice of the cathode m the gun and its efficiency. Tentative designs of laser systems for the TESLA test facility and LCLS had been drawn assuming a copper cathode. Using a more efficient cathode will ease the energy requirement of the laser and simplify the design. The individual papers have been cataloged separately elsewhere

  2. ION GUN

    Science.gov (United States)

    Dandl, R.A.

    1961-10-24

    An ion gun is described for the production of an electrically neutral ionized plasma. The ion gun comprises an anode and a cathode mounted in concentric relationship with a narrow annulus between. The facing surfaces of the rear portions of the anode and cathode are recessed to form an annular manifold. Positioned within this manifold is an annular intermediate electrode aligned with the an nulus between the anode and cathode. Gas is fed to the manifold and an arc discharge is established between the anode and cathode. The gas is then withdrawn from the manifold through the annulus between the anode and cathode by a pressure differential. The gas is then ionized by the arc discharge across the annulus. The ionized gas is withdrawn from the annulus by the combined effects of the pressure differential and a collimating magnetic field. In a 3000 gauss magnetic field, an arc voltage of 1800 volts, and an arc current of 0.2 amp, a plasma of about 3 x 10/sup 11/ particles/cc is obtained. (AEC)

  3. Gun ownership and social gun culture.

    Science.gov (United States)

    Kalesan, Bindu; Villarreal, Marcos D; Keyes, Katherine M; Galea, Sandro

    2016-06-01

    We assessed gun ownership rates in 2013 across the USA and the association between exposure to a social gun culture and gun ownership. We used data from a nationally representative sample of 4000 US adults, from 50 states and District of Columbia, aged >18 years to assess gun ownership and social gun culture performed in October 2013. State-level firearm policy information was obtained from the Brady Law Center and Injury Prevention and Control Center. One-third of Americans reported owning a gun, ranging from 5.2% in Delaware to 61.7% in Alaska. Gun ownership was 2.25-times greater among those reporting social gun culture (PR=2.25, 95% CI 2.02 to 2.52) than those who did not. In conclusion, we found strong association between social gun culture and gun ownership. Gun cultures may need to be considered for public health strategies that aim to change gun ownership in the USA. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  4. Encyclopedia of Gun Control and Gun Rights.

    Science.gov (United States)

    Utter, Glenn H.

    This reference volume provides information on gun control and gun rights, including resources on the debate surrounding the Second Amendment and individuals and organizations focused on gun issues, along with statutes, court cases, events, and publications surrounding this current topic. Highlighted are the important organizations and their…

  5. Conceptual Design for CLIC Gun Pulser

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Tao [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2016-01-08

    The Compact Linear Collider (CLIC) is a proposed future electron-positron collider, designed to perform collisions at energies from 0.5 to 5 TeV, with a nominal design optimized for 3 TeV (Dannheim, 2012). The Drive Beam Accelerator consists of a thermionic DC gun, bunching section and an accelerating section. The thermionic gun needs deliver a long (~143us) pulse of current into the buncher. A pulser is needed to drive grid of the gun to generate a stable current output. This report explores the requirements of the gun pulser and potential solutions to regulate grid current.

  6. High Peak Power Test and Evaluation of S-band Waveguide Switches

    Science.gov (United States)

    Nassiri, A.; Grelick, A.; Kustom, R. L.; White, M.

    1997-05-01

    The injector and source of particles for the Advanced Photon Source is a 2856-MHz S-band electron-positron linear accelerator (linac) which produces electrons with energies up to 650 MeV or positrons with energies up to 450 MeV. To improve the linac rf system availability, an additional modulator-klystron subsystem is being constructed to provide a switchable hot spare unit for each of the five exsisting S-band transmitters. The switching of the transmitters will require the use of SF6-pressurized S-band waveguide switches at a peak operating power of 35 MW. Such rf switches have been successfully operated at other accelerator facilities but at lower peak powers. A test stand has been set up at the Stanford Linear Accelerator Center (SLAC) Klystron Factory to conduct tests comparing the power handling characteristics of two WR-284 and one WR-340 switches. Test results are presented and their implications for the design of the switching system are discussed.

  7. Development of an S-band cavity Beam Position Monitor for ATF2

    Science.gov (United States)

    Heo, A.; Kim, E.-S.; Kim, H.; Son, D.; Honda, Y.; Tauchi, T.

    2013-04-01

    We have developed an S-band cavity Beam Position Monitor (BPM) in order to measure the position of an electron beam in the final focus area at ATF2, which is the test facility for the final focus design for the International Linear Collider (ILC). The lattice of the ILC Beam Delivery System (BDS) has been modified, requiring a larger physical aperture of 40 mm in the final focus area. The beam orbit measurement in this area is now covered with high resolution S-Band cavity BPMs. In this paper we summarize the design of the cavity BPM and the first experimental results. The calibration slopes were measured as 0.87 counts/μm in the x-coordinate direction and 1.16 counts/μm in the y-coordinate direction.

  8. Experimental study of matrix carbon field-emission cathodes and computer aided design of electron guns for microwave power devices, exploring these cathodes

    International Nuclear Information System (INIS)

    Grigoriev, Y.A.; Petrosyan, A.I.; Penzyakov, V.V.; Pimenov, V.G.; Rogovin, V.I.; Shesterkin, V.I.; Kudryashov, V.P.; Semyonov, V.C.

    1997-01-01

    The experimental study of matrix carbon field-emission cathodes (MCFECs), which has led to the stable operation of the cathodes with current emission values up to 100 mA, is described. A method of computer aided design of TWT electron guns (EGs) with MCFEC, based on the results of the MCFEC emission experimental study, is presented. The experimental MCFEC emission characteristics are used to define the field gain coefficient K and the cathode effective emission area S eff . The EG program computes the electric field upon the MCFEC surface, multiplies it by the K value and uses the Fowler Nordheim law and the S eff value to calculate the MCFEC current; the electron trajectories are computed as well. copyright 1997 American Vacuum Society

  9. Performance review of an indigenously developed high power test stand built for the Indian S-band 5 MW pulsed klystron development

    International Nuclear Information System (INIS)

    Shrivastava, Purushottam; Baxy, D.; Mulchandani, J.; Hannurkar, P.R.; Joshi, L.M.

    2003-01-01

    CAT took up development of 5 MW S-Band klystrons indigenously in collaboration with CEERI Pilani. The development of klystron prototype is completed. These klystrons are very crucial devices, for energizing the 10-20 MeV electron accelerators, which are developed in the country for various industrial, medical and scientific applications. A test station has been developed indigenously at CAT for these klystrons. It consists of a 12 MW peak power 130 kV klystron pulse modulator, a 1 : 10 pulse transformer, 130 kV high voltage deck having high voltage pulse divider, pulse current transformer as well indigenously built klystron socket, filament supplies, klystron support structure and pulse transformer oil tank. After development/rigorous testing the test stand was shifted to CEERI and was installed and commissioned there by CAT. Gun collector test module and prototypes of the 5 MW klystron were tested, aged and conditioned at high power using this test stand. The details of the system / test results are discussed

  10. Gun control saves lives

    African Journals Online (AJOL)

    gun control legislation. One study estimated that more than 4 500 lives were saved across five SA cities from 2001 to 2005.[5] Pro-gun interest groups seeking to promote gun ownership and diffusion have attacked these findings, suggesting that stricter gun control was only enacted in 2004 following the publication of ...

  11. Gun Sales. Firearm Facts.

    Science.gov (United States)

    Duker, Laurie, Ed.

    Minimal federal regulations on firearm sales have facilitated the proliferation of guns, gun owners, and gun dealers in the United States. This fact sheet offers data on the growing number of firearm dealers, the relative ease of obtaining and keeping a license to sell guns from the Federal Bureau of Alcohol, Tobacco, and Firearms, the lack of…

  12. ANALYTICAL MODELING OF ELECTRON BACK-BOMBARDMENT INDUCED CURRENT INCREASE IN UN-GATED THERMIONIC CATHODE RF GUNS

    Energy Technology Data Exchange (ETDEWEB)

    Edelen, J. P. [Fermilab; Sun, Y. [Argonne; Harris, J. R. [AFRL, NM; Lewellen, J. W. [Los Alamos Natl. Lab.

    2016-09-28

    In this paper we derive analytical expressions for the output current of an un-gated thermionic cathode RF gun in the presence of back-bombardment heating. We provide a brief overview of back-bombardment theory and discuss comparisons between the analytical back-bombardment predictions and simulation models. We then derive an expression for the output current as a function of the RF repetition rate and discuss relationships between back-bombardment, fieldenhancement, and output current. We discuss in detail the relevant approximations and then provide predictions about how the output current should vary as a function of repetition rate for some given system configurations.

  13. Life test on indigenous s-band pulsed magnetron

    International Nuclear Information System (INIS)

    Wanmode, Y.D.; Shrivastava, P.; Hannurkar, P.R.

    1999-01-01

    A 2 MW S-band pulsed magnetron has been developed under joint collaboration between CAT and CEERI. In this development effort several lab prototypes were evaluated on 2 MW microwave test facility developed at CAT. One magnetron is subjected to life test. The present paper describes the setup and procedures used for life test. Various observations and corrections made during the life tests are also described. Results of the tests are discussed. (author)

  14. Measurements of line-averaged electron density of pulsed plasmas using a He-Ne laser interferometer in a magnetized coaxial plasma gun device

    Science.gov (United States)

    Iwamoto, D.; Sakuma, I.; Kitagawa, Y.; Kikuchi, Y.; Fukumoto, N.; Nagata, M.

    2012-10-01

    In next step of fusion devices such as ITER, lifetime of plasma-facing materials (PFMs) is strongly affected by transient heat and particle loads during type I edge localized modes (ELMs) and disruption. To clarify damage characteristics of the PFMs, transient heat and particle loads have been simulated by using a plasma gun device. We have performed simulation experiments by using a magnetized coaxial plasma gun (MCPG) device at University of Hyogo. The line-averaged electron density measured by a He-Ne interferometer is 2x10^21 m-3 in a drift tube. The plasma velocity measured by a time of flight technique and ion Doppler spectrometer was 70 km/s, corresponding to the ion energy of 100 eV for helium. Thus, the ion flux density is 1.4x10^26 m-2s-1. On the other hand, the MCPG is connected to a target chamber for material irradiation experiments. It is important to measure plasma parameters in front of target materials in the target chamber. In particular, a vapor cloud layer in front of the target material produced by the pulsed plasma irradiation has to be characterized in order to understand surface damage of PFMs under ELM-like plasma bombardment. In the conference, preliminary results of application of the He-Ne laser interferometer for the above experiment will be shown.

  15. Modulators for the S-band test linac at DESY

    Science.gov (United States)

    Bieler, M.; Choroba, S.; Hameister, J.; Lewin, H.-Ch.

    1995-07-01

    The development of adequate modulators for high peak power klystrons is one of the focus points for linear collider R&D programs. For the DESY/THD S-band linear collider study 150 MW rf-pulse power at 50 Hz repetition rate and 3 μs pulse duration is required [1]. Two different modulator schemes are under investigation. One is the conventional line type pulser, using a pulse forming network and a step up transformer, the other one is a hard tube pulser, using a dc power source at the full klystron voltage and a switch tube. This paper is focused on the modulator development for the S-band Test Linac at DESY. After a short overview over the test linac and a brief description of the 150 MW S-band klystron the circuitry of the line type pulse (LTP) is given. A hard tube pulser (HTP), which switches the high voltage directly from a storage capacitor to the klystron, has been built up at DESY. Circuitry and the results of the commissioning of the switch tube are reported.

  16. Study of Control Grid Thermionic Cathode RF Gun

    CERN Document Server

    Xiao, Jin; Ming, Li; Xinfan, Yang; Xumin, Shen; Yanan, Chen; Zhou, Xu

    2004-01-01

    In this paper, the beam loading effect of RF Gun was analyzed. To minimize the energy spread, the grid control RF Gun was introduced. The result shows that the grid congrol RF Gun can increase electron beam within 1% energy spread.

  17. S-band 45 MW peak power test facility at RRCAT

    International Nuclear Information System (INIS)

    Wanmode, A. Yashwant; Reddy, Sivananda; Mulchandani, J.; Mohania, Praveen; Shrivastava, B. Purushottam

    2015-01-01

    RRCAT is engaged in the design and development of high energy electron LINAC as future injectors for the Booster Synchrotron for Indus-1 and Indus-2 SRS. The high energy LINAC will need microwave power over 30 MW depending on the number of structures to be energized. In order to have advance preparations for this development a 45 MW S-Band test facility has been designed and developed at RRCAT. The test stand is built around a 45 MW peak power S-band pulsed klystron, A conventional pulse forming network based modulator for klystron has been designed and developed. The WR-284 waveguide transmission system consisting of dual directional couplers, SF 6 gas pressurization unit, high power waveguide load and arc sensor has been developed and interfaced with the klystron. The klystron has been successfully tested up to 30 MW peak power at 2856 MHz on SF 6 pressurized waveguide line. A solid state S Band driver amplifier up to 1 kW output power was designed developed for driving the klystron. This paper describes the results of 30 MW peak power test of this facility. (author)

  18. Effective shunt impedance comparison between s-band standing wave accelerators with on-axis and off-axis couplers

    International Nuclear Information System (INIS)

    Schriber, S.O.; Funk, L.W.; Hutcheon, R.M.

    1976-01-01

    The effective shunt impedances of a side-coupled S-band standing wave accelerating structure and a structure employing on-axis couplers have been compared by measuring the energy of accelerated electrons. Criteria for choosing an on-axis coupled structure compared to side-coupled and ''disk and washer'' accelerating structures are given. (author)

  19. Development of a Robust, High Current, Low Power Field Emission Electron Gun for a Spaceflight Reflectron Time-of-Flight Mass Spectrometer

    Science.gov (United States)

    Southard, Adrian E.; Getty, Stephanie A.; Feng, Steven; Glavin, Daniel P.; Auciello, Orlando; Sumant, Anirudha

    2012-01-01

    Carbon materials, including carbon nanotubes (CNTs) and nitrogen-incorporated ultrananocrystalline diamond (N-UNCD), have been of considerable interest for field emission applications for over a decade. In particular, robust field emission materials are compelling for space applications due to the low power consumption and potential for miniaturization. A reflectron time-of-flight mass spectrometer (TOF-MS) under development for in situ measurements on the Moon and other Solar System bodies uses a field emitter to generate ions from gaseous samples, using electron ionization. For these unusual environments, robustness, reliability, and long life are of paramount importance, and to this end, we have explored the field emission properties and lifetime of carbon nanotubes and nitrogen-incorporated ultrananocrystalline diamond (N-UNCD) thin films, the latter developed and patented by Argonne National Laboratory. We will present recent investigations of N-UNCD as a robust field emitter, revealing that this material offers stable performance in high vacuum for up to 1000 hours with threshold voltage for emission of about 3-4 V/lJm and current densities in the range of tens of microA. Optimizing the mass resolution and sensitivity of such a mass spectrometer has also been enabled by a parallel effort to scale up a CNT emitter to an array measuring 2 mm x 40 mm. Through simulation and experiment of the new extended format emitter, we have determined that focusing the electron beam is limited due to the angular spread of the emitted electrons. This dispersion effect can be reduced through modification of the electron gun geometry, but this reduces the current reaching the ionization region. By increasing the transmission efficiency of the electron beam to the anode, we have increased the anode current by two orders of magnitude to realize a corresponding enhancement in instrument sensitivity, at a moderate cost to mass resolution. We will report recent experimental and

  20. ATA injector-gun calculations

    International Nuclear Information System (INIS)

    Paul, A.C.

    1981-01-01

    ATA is a pulsed, 50 ns 10 KA, 50 MeV linear induction electron accelerator at LLNL. The ETA could be used as an injector for ATA. However the possibility of building a new injector gun for ATA, raised the question as to what changes from the ETA gun in electrode dimensions or potentials, if any, should be considered. In this report the EBQ code results for the four electrode configurations are reviewed and an attempt is made to determine the geometrical scaling laws appropriate to these ETA type gun geometries. Comparison of these scaling laws will be made to ETA operation. The characteristic operating curves for these geometries will also be presented and the effect of washer position determined. It will be shown that emittance growth will impose a limitation on beam current for a given anode potential before the virtual cathode limit is reached

  1. Plasma focusing in coaxial gun

    International Nuclear Information System (INIS)

    Soliman, H.M.; Masoud, M.M.; El-Khalafawy, T.

    1986-01-01

    A capacitor bank has been discharged between two coaxial electrodes of 6.6 cm outer diameter, 3.2 cm inner diameter and length of 31.5 cm. filled with hydrogen gas at pressure of 310 μHg. Results show that, the axial and radial plasma current reach a maximum value at a position adjacent to the gun muzzle, at which the plasma focus occurs. The measurement of the electron temperature and density and azimuthal electric field along the axis of the expansion chamber, gives a maximum value at z∼18 cm from the gun muzzle, while the axial plasma current and velocity has a minimum value at that position. These results indicate that a second point of a plasma focus has been formed at z∼18 cm from the gun muzzle, along the axis of the expansion chamber

  2. Guns and Violence. Current Controversies.

    Science.gov (United States)

    Kim, Henny H., Ed.

    This book focuses on gun violence and gun control, presenting both sides of arguments about firearms ownership and gun control. Each of five chapters poses a question about gun control and provides answers for both sides of the question. The following essays are included: (1) "Gun Violence Is Becoming an Epidemic" (Bob Herbert); (2) "Gun Violence…

  3. Characteristics of typical Pierce guns for PPM focused TWTs

    International Nuclear Information System (INIS)

    Harper, R.; Puri, M.P.

    1989-01-01

    The performance of typical moderate perveance Pierce type electron guns which are used in periodic permanent magnet focused traveling wave tubes are described with regard to adaptation for use in electron beam ion sources. The results of detailed electron trajectory computations for one particular gun design are presented

  4. Low power microwave tests on RF gun prototype of the Iranian Light Source Facility

    Directory of Open Access Journals (Sweden)

    A Sadeghipanah

    2017-08-01

    Full Text Available In this paper, we introduce RF electron gun of Iranian Light Source Facility (ILSF pre-injection system. Design, fabrication and low-power microwave tests results of the prototype RF electron gun have been described in detail. This paper also explains the tuning procedure of the prototype RF electron gun to the desired resonant frequency. The outcomes of this project brighten the path to the fabrication of the RF electron gun by the local industries  

  5. Characteristics of the ETA gun

    International Nuclear Information System (INIS)

    Paul, A.C.; Neil, V.K.; Craig, G.D.; Fessenden, T.J.

    1981-01-01

    The Experimental Test Accelerator (ETA) is a linear induction device consisting of a 2.5-MV electron gun and ten 0.25-MV accelerating units designed to produce a 10-kA beam of electrons at 5 MeV. Calculations with the computer code EBQ as well as experimental measurements indicate that the current produced by the gun is limited by two phenomena. The first arises from the variation of particle energy with time during the pulse. Only particles with energy within a limited range can be transported by the focusing coils in the gun: therefore the variation of the gun's output current with time is determined by the coil settings. The second effect results from a collective interaction at sufficiently large current to cause a virtual cathode to form a few centimeters past the extraction grid. Operation in this regime results in greatly increased beam emittance and poor beam transport through the accelerator. Results of the code calculations are compared with experimental data and found to be in good agreement. (author)

  6. Description of the plasma diagnostics package (PDP) for the OSS-1 Shuttle mission and JSC plasma chamber test in conjunction with the fast pulse electron gun (FPEG)

    Science.gov (United States)

    Shawhan, S. D.

    1982-01-01

    The objectives, equipment, and techniques for the plasma diagnostics package (PDP) carried by the OSS-1 instrument payload of the STS-4 and scheduled for the Spacelab-2 mission are described. The goals of the first flight were to examine the Orbiter-magnetoplasma interactions by measuring the electric and magnetic field strengths, the ionized particle wakes, and the generated waves. The RMS was employed to lift the unit out of the bay in order to allow characterization of the fields, EM interference, and plasma contamination within 15 m of the Orbiter. The PDP will also be used to examine plasma depletion, chemical reaction rates, waves, and energized plasma produced by firing of the Orbiter thrusters. Operation of the PDP was carried out in the NASA Space Environment Simulation Laboratory test chamber, where the PDP was used to assay the fields, fluxes, wave amplitudes, and particle energy spectra. The PDP instrumentation is also capable of detecting thermal ions, thermal electrons suprathermal particles, VHF/UHF EMI levels, and the S-band field strength.

  7. Gun Theft and Crime.

    Science.gov (United States)

    Cook, Philip J

    2018-06-01

    Some law enforcement officials and other observers have asserted that theft is the primary source of guns to crime. In fact, the role of theft in supplying the guns used in robbery, assault, and murder is unknown, and current evidence provides little guidance about whether an effective program to reduce gun theft would reduce gun violence. The current article analyzes publicly available national data on gun theft together with a unique data set for Chicago. The results tend to support a conclusion that stolen guns play only a minor role in crime. First, publicly available data are used to calculate that thefts are only about 1% of all gun transactions nationwide. Second, an analysis of original data from Chicago demonstrates that less than 3% of crime guns recovered by the police have been reported stolen to the Chicago Police Department (CPD). If a gun is reported stolen, there is a 20% chance that it will be recovered, usually in conjunction with an arrest for illegal carrying. Less than half of those picked up with a stolen gun have a criminal record that includes violent offenses. Third, results from surveys of convicted criminals, both nationally and in Chicago, suggest that it is rare for respondents to have stolen the gun used in their most recent crime. The data on which these results are based have various shortcomings. A research agenda is proposed that would provide more certainty about the role of theft.

  8. Low emittance design of the electron gun and the focusing channel of the Compact Linear Collider drive beam

    Directory of Open Access Journals (Sweden)

    M. Dayyani Kelisani

    2017-04-01

    Full Text Available For the Compact Linear Collider project at CERN, the power for the main linacs is extracted from a drive beam generated from a high current electron source. The design of the electron source and its subsequent focusing channel has a great impact on the beam dynamic considerations of the drive beam. We report the design of a thermionic electron source and the subsequent focusing channels with the goal of production of a high quality beam with a very small emittance.

  9. Performance of the Brookhaven photocathode rf gun

    International Nuclear Information System (INIS)

    Batchelor, K.; Ben-Zvi, I.; Fernow, R.C.; Fischer, J.; Fisher, A.S.; Gallardo, J.; Ingold, G.; Kirk, H.G.; Leung, K.P.; Malone, R.; Pogorelsky, I.; Srinivasan-Rao, T.; Rogers, J.; Tsang, T.; Sheehan, J.; Ulc, S.; Woodle, M.; Xie, J.; Zhang, R.S.; Lin, L.Y.; McDonald, K.T.; Russell, D.P.; Hung, C.M.; Wang, X.J.

    1991-01-01

    The Brookhaven Accelerator Test Facility (ATF) uses a photocathode rf gun to provide a high-brightness electron beam intended for FEL and laser-acceleration experiments. The rf gun consists of 1 1/2 cells driven at 2856 MHz in π-mode with a maximum cathode field of 100 MV/m. To achieve long lifetimes, the photocathode development concentrates on robust metals such as copper, yttrium and samarium. We illuminate these cathodes with a 10-ps, frequency-quadrupled Nd:YAG laser. We describe the initial operation of the gun, including measurements of transverse and longitudinal emittance, quantum efficiencies, and peak current. The results are compared to models

  10. Beam emittance measurement from CERN thermionic guns

    International Nuclear Information System (INIS)

    Kester, O.; Rao, R.; Rinolfi, L.

    1992-01-01

    In the LEP Injector Linacs (LIL) a thermionic gun provides electron beams with different peak intensities at an energy of 80 keV. The beam emittances were estimated from the EGUN programme. Since the gun is of triode type, the main contribution to the emittance comes from the grid. The simulation programme does not model the real geometry by assuming a cylindrical symmetry, while the grid does not have such symmetry. A Gun Test Facility (GTF), allowing emittance measurements, based on the 3-gradients-method was installed. The experimental results are presented. (author) 6 refs.; 6 figs

  11. Whose guns are stolen? The epidemiology of Gun theft victims.

    Science.gov (United States)

    Hemenway, David; Azrael, Deborah; Miller, Matthew

    2017-12-01

    Gun theft is an important source of guns used by criminals. Yet no empirical work has focused on the characteristics of gun owners that distinguish those who have had their guns stolen from those who have not. In this study, we examine the demographics and behavioral characteristics of gun owners who report having had a gun stolen. Data come from a nationally representative probability-based online survey conducted in April 2015, with a linked follow-up survey in November 2015 that asked gun owners about any theft of their guns in the past 5 years. Of 1,604 gun-owning respondents, 2.4% (95% CI 1.6,3.6) reported that one or more guns had been stolen, with a mean number of guns stolen per theft of 1.5 (95% CI 1.0,2.0]. Risk factors for having a gun stolen were owning 6 or more guns, owning guns for protection, carrying a gun in the past month, storing guns unsafely, and living in the South region of the United States. The South accounts for 37% of US households, 43% of gun owners, and two-thirds of all gun thefts. We estimate that there are approximately 250,000 gun theft incidents per year, with about 380,000 guns stolen. We find that certain types of gun owners-who own many guns, who carry guns, and who do not store guns safely-are at higher risk to have their guns stolen. Tracing data show that states in the South are exporters of crime guns used in other states. Our survey results find that the majority of guns stolen in the US come from the South.

  12. Observation of dark-current signals from the S-band structures of the SLAC linac

    International Nuclear Information System (INIS)

    Assmann, R.; Decker, F.J.; Seidel, M.; Siemann, R.H.; Whittum, D.

    1997-07-01

    It is well known that the electro-magnetic fields in high-gradient RF structures can cause electron emission from the metallic structure walls. If the emitted electrons are captured and accelerated by the accelerating fields so-called dark-current is induced. Dark-currents have been measured and studied for various RF-structures. In this paper the authors present measurements of RF induced signals for the SLC S-band structures. For nominal gradients of 17 MV/m it is shown that the dark-current can be strong enough to significantly reduce the signal-to-noise ratio of the SLC beam wire scanners. They also show results from RF measurements in the dipole band. The measurements are compared to more direct observations of dark-current and it is tried to connect the results to possible effects on the accelerated particle beam

  13. Design and performance of large area monolithic electron guns for the Aurora KrF laser system

    International Nuclear Information System (INIS)

    Kang, M.; Rosocha, L.A.; Romero, V.O.; Van Haaften, F.W.; Brucker, J.P.

    1985-01-01

    Aurora is an inertial confinement fusion laser system using optical angular multiplexing and a chain of four cold cathode electron beam driven KrF laser amplifiers to produce 10 to 20 kJ of optical energy

  14. S-band and X-band integrated PWT photoelectron linacs

    International Nuclear Information System (INIS)

    Yu, D.; Newsham, D.; Zeng, J.; Rosenzweig, J.

    2001-01-01

    A compact high-energy injector, which has been developed by DULY Research Inc., will have wide scientific, industrial, and medical applications. The new photoelectron injector integrates the photocathode directly into a multicell linear accelerator. By focusing the beam with solenoids or permanent magnets, and producing high current with low emittance, high brightness and low energy spread are achieved. In addition to providing a small footprint and improved beam quality in an integrated structure, the compact system considerably simplifies external subsystems required to operate the photoelectron linac, including rf power transport, beam focusing, vacuum and cooling. The photoelectron linac employs an innovative Plane-Wave-Transformer (PWT) design, which provides strong cell-to-cell coupling, relaxes manufacturing tolerances and facilitates the attachment of external ports to the compact structure with minimal field interference. DULY Research Inc. under the support of the DOE Small Business Innovation Research (SBIR) program, has developed, constructed and installed a 20-MeV, S-band compact electron source at UCLA. Cold test results for this device are presented. DULY Research is also actively engaged in the development of an X-band photoelectron linear accelerator in a SBIR project. When completed, the higher frequency structure will be approximately three times smaller. Design considerations for this device are discussed following the S-band cold test results

  15. Characterestics of pico-second single bunch at the S-band linear accelerator

    International Nuclear Information System (INIS)

    Uesaka, Mitsuru; Kozawa, Takahiro; Kobayashi, Toshiaki; Ueda, Toru; Miya, Kenzo

    1994-01-01

    Measurement of the bunch structure of a pico-second single bunch was performed using a femto-second streak camera at the S-band linear accelerator of the University of Tokyo. The aim of this research is to investigate the feasibility of the generation of a femto-second single bunch at the S-band linac. The details of the bunch structure and energy spectrum of an original single bunch were precisely investigated in several operation modes where the RF phases in accelerating tubes and a prebuncher were varied. The femto-second streak camera was utilized to measure the bunch structure by one shot via Cherenkov radiation emitted by the electrons in the bunch. Next, an experiment for magnetic pulse compression of the original single bunch was carried out. Pulse shapes of the compressed bunchs for different energy modulation were also obtained by measuring Cherenkov radiation by one shot using the femto-second streak camera. Prior to the experiment, numerical tracking analysis to determine operating parameters for the magnetic pulse compression was also done. Measured pulse widths were compared with calculated ones. Finally, a 2 ps (full width at half maximum; FWHM) single bunch with an electric charge of 0.3 nC could be generated by the magnetic pulse compression. ((orig.))

  16. Geometry Optimization of DC/RF Photoelectron Gun

    CERN Document Server

    Chen Ping; Yu, David

    2005-01-01

    Pre-acceleration of photoelectrons in a pulsed, high voltage, short, dc gap and its subsequent injection into an rf gun is a promising method to improve electron beam emittance in rf accelerators. Simulation work has been performed in order to optimize the geometric shapes of a dc/rf gun and improve electron beam properties. Variations were made on cathode and anode shapes, dc gap distance, and inlet shape of the rf cavity. Simulations showed that significant improvement on the normalized emittance (< 1 mm-mrad), compared to a dc gun with flat cathode, could be obtained after the geometric shapes of the gun were optimized.

  17. Carbon plasma gun

    International Nuclear Information System (INIS)

    Mendel, C.W. Jr.; Zagar, D.M.; Mills, G.S.; Humphries, S. Jr.; Goldstein, S.A.

    1980-01-01

    A family of plasma guns supplying highly ionized carbon plasma is described. The guns are simple and inexpensive to construct and are pulsed by small capacitor banks of a few hundred joules. The output consists of 10 17 --10 18 multiply ionized carbon ions traveling at about 10 7 cm/s. Neutral output is very low and arrives well after the ionized carbon. The guns and pulsers are very reliable

  18. Simplified pipe gun

    International Nuclear Information System (INIS)

    Sorensen, H.; Nordskov, A.; Sass, B.; Visler, T.

    1987-01-01

    A simplified version of a deuterium pellet gun based on the pipe gun principle is described. The pipe gun is made from a continuous tube of stainless steel and gas is fed in from the muzzle end only. It is indicated that the pellet length is determined by the temperature gradient along the barrel right outside the freezing cell. Velocities of around 1000 m/s with a scatter of +- 2% are obtained with a propellant gas pressure of 40 bar

  19. Transient effects in beam-plasma interactions in a space simulation chamber stimulated by a fast pulse electron gun

    Science.gov (United States)

    Raitt, W. J.; Banks, P. M.; Denig, W. F.; Anderson, H. R.

    1982-01-01

    Interest in the interaction of electron beams with plasma generated by ionization caused by the primary electron beam was stimulated by the need to develop special vacuum tubes to operate in the kMHz frequency region. The experiments of Getty and Smullin (1963) indicated that the interaction of an energetic electron beam with its self-produced plasma resulted in the emission of wave energy over a wide range of frequencies associated with cyclotron and longitudinal plasma instabilities. This enhanced the thermal plasma density in the vicinity of the beam, and the term Beam-Plasma Discharge (BPD) was employed to described this phenomenon. The present investigation is concerned with some of the transient phenomena associated with wave emission during the beam switch-on and switch-off periods. Results are presented on the changes in electron energy spectra on a time scale of tens of milliseconds following beam switch-on. The results are discussed in terms of the beam plasma discharge phenomenon.

  20. Transient effects in beam-plasma interactions in a space simulation chamber stimulated by a fast pulse electron gun

    International Nuclear Information System (INIS)

    Raitt, W.J.; Banks, P.M.

    1982-01-01

    Interest in the interaction of electron beams with plasma generated by ionization caused by the primary electron beam was stimulated by the need to develop special vacuum tubes to operate in the kMHz frequency region. The experiments of Getty and Smullin (1963) indicated that the interaction of an energetic electron beam with its self-produced plasma resulted in the emission of wave energy over a wide range of frequencies associated with cyclotron and longitudinal plasma instabilities. This enhanced the thermal plasma density in the vicinity of the beam, and the term Beam-Plasma Discharge (BPD) was employed to described this phenomenon. The present investigation is concerned with some of the transient phenomena associated with wave emission during the beam switch-on and switch-off periods. Results are presented on the changes in electron energy spectra on a time scale of tens of milliseconds following beam switch-on. The results are discussed in terms of the beam plasma discharge phenomenon. 5 references

  1. Therminoic gun control system for the CEBAF injector

    International Nuclear Information System (INIS)

    Pico, R.; Diamond, B.; Fugitt, J.; Bork, R.

    1989-01-01

    The injector for the CEBAF accelerator must produce a high-quality electron beam to meet the overall accelerator specifications. A Hermosa electron gun with a 2 mm-diameter cathode and a control aperture has been chosen as the electron source. This must be controlled over a wide range of operating conditions to meet the beam specifications and to provide flexibility for accelerator commissioning. The gun is controlled using Computer Automated Measurement and Control (CAMAC IEEE-583) technology. The system employs the CAMAC-based control architecture developed at CEBAF. The control system has been tested, and early operating data on the electron gun and the injector beam transport system has been obtained. This system also allows gun parameters to be stored at the operator location, without paralyzing operation. This paper describes the use of this computer system in the control of the CEBAF electron gun. 2 refs., 6 figs., 1 tab

  2. Magnetized gun experiments

    International Nuclear Information System (INIS)

    Jarboe, T.R.; Henins, I.; Hoida, H.W.; Marshall, J.; Sherwood, A.R.

    1981-01-01

    In the Los Alamos Magnetized Gun Experiment we are attempting to produce a compact torus in a manner similar to an earlier experiment of Alfven. In our experiment a solenoidal coil is placed inside the inner electrode of a coaxial plasma gun. This coil produces an axial magnetic field inside the inner electrode which diverges and becomes a largely radial field in front of the gun muzzle. The idea is that when the gun is fired, the plasma escaping from the gun stretches these radial fields along the axial direction away from the gun, and these field lines can reconnect behind the plasma forming the poloidal field of the compact torus. The magnetic field generated by the gun current becomes the toroidal field and the major axis of the compact torus will be the same as the axis of the coaxial gun. Recent interest in this possible method of compact torus generation was stimulated by C. Hartman, and the approach is also being pursued in the field-reversed plasma gun experiment at LLL

  3. Design and development of low level S-Band RF control system for IRFEL injector LINAC

    International Nuclear Information System (INIS)

    Mohania, Praveen; Mahawar, Ashish; Singh, Adarsh Pratap; Namdeo, Rajkumar; Baxy, Deodatta; Shrivastava, Purushottam

    2015-01-01

    A low level RF system has been designed and developed for phase and amplitude stabilization of S- Band microwave power being fed to fundamental buncher cavity and the injector LINAC structure of the Infra Red Free Electron Laser being developed at RRCAT Indore. The system uses analog phase shifters and voltage variable attenuators to control the phase and amplitude respectively, the control voltages for phase shifters and attenuators are generated using a 12 Bit ADC and is software controlled. The system has a slow feedback to correct phase and amplitude drifts occurring due to thermal variations and a fast feed forward mechanism to vary amplitude and phase of the output pulse to compensate beam loading and to shape the klystron output power. The present paper describes the design aspects of the LLRF system. (author)

  4. Emittance Measurements from a Laser Driven Electron Injector

    CERN Document Server

    Reis, D

    2003-01-01

    The Gun Test Facility (GTF) at the Stanford Linear Accelerator Center was constructed to develop an appropriate electron beam suitable for driving a short wavelength free electron laser (FEL) such as the proposed Linac Coherent Light Source (LCLS). For operation at a wavelength of 1.5 (angstrom), the LCLS requires an electron injector that can produce an electron beam with approximately 1 pi mm-mrad normalized rms emittance with at least 1 nC of charge in a 10 ps or shorter bunch. The GTF consists of a photocathode rf gun, emittance-compensation solenoid, 3 m linear accelerator (linac), drive laser, and diagnostics to measure the beam. The rf gun is a symmetrized 1.6 cell, s-band high gradient, room temperature, photocathode structure. Simulations show that this gun when driven by a temporally and spatially shaped drive laser, appropriately focused with the solenoid, and further accelerated in linac can produce a beam that meets the LCLS requirements. This thesis describes the initial characterization of the ...

  5. Gun Safety (For Parents)

    Science.gov (United States)

    ... from the home of a relative or friend. Teens should never be able to get to a gun and bullets without an adult being there. People of any age who are depressed are at increased risk of suicide. If someone in the family has depression, or has had thoughts of suicide, all guns ...

  6. Guns at College.

    Science.gov (United States)

    Miller, Matthew; Hemenway, David; Wechsler, Henry

    1999-01-01

    Surveyed undergraduate students nationwide concerning firearm possession. About 3.5% possessed working firearms. Students with guns were more likely to be male, White, or Native American; binge drink; live off-campus; and live with a spouse or significant other. Students with guns were more likely to engage in activities that put themselves and…

  7. Remotely controlled spray gun

    Science.gov (United States)

    Cunningham, William C. (Inventor)

    1987-01-01

    A remotely controlled spray gun is described in which a nozzle and orifice plate are held in precise axial alignment by an alignment member, which in turn is held in alignment with the general outlet of the spray gun by insert. By this arrangement, the precise repeatability of spray patterns is insured.

  8. Start-to-end simulation of self-amplified spontaneous emission free electron lasers from the gun through the undulator

    CERN Document Server

    Borland, M M; Emma, P; Lewellen, J W; Bharadwaj, V K; Fawley, W M; Krejcik, P; Limborg, C; Milton, S V; Nuhn, H D; Soliday, R; Woodley, M

    2002-01-01

    It is widely appreciated that the performance of self-amplified spontaneous emission free-electron lasers (FELs) depends critically on the properties of the drive beam. In view of this, a multi-laboratory collaboration has explored methods and software tools for integrated simulation of the photoinjector, linear accelerator, bunch compressor, and FEL. Rather than create a single code to handle such a system, our goal has been a robust, generic solution wherein pre-existing simulation codes are used sequentially. We have standardized on the use of Argonne National Laboratory's Self-Describing Data Sets file protocol for transfer of data among codes. The simulation codes used are PARMELA, elegant, and GENESIS. We describe the software methodology and its advantages, then provide examples involving Argonne's Low-Energy Undulator Test Line and Stanford Linear Accelerator Center's Linac Coherent Light Source. We also indicate possible future direction of this work.

  9. Function of bunching segment in multi-cell RF gun

    International Nuclear Information System (INIS)

    Yang Xingfan; Xu Zhou Liu Xisan

    2001-01-01

    With a bunching segment and a shortened first cell, the 4 + 1/2 cell RF gun produced in CAEP has been proved experimentally to be effective in reducing electron back bombardment. The analysis of the electric field distribution and electron motion in bunching segment of multi-cell RF gun is presented. The electron capture efficiency and electron trajectory with different initial phase are calculated using Runge-Kutta method. The function of the bunching segment is discussed. The calculated parameters of the 4 + 1/2 cell RF gun agree well with the experimental results

  10. Design, construction and measurements of an alpha magnet as a solution for compact bunch compressor for the electron beam from Thermionic RF Gun

    Science.gov (United States)

    Rajabi, A.; Jazini, J.; Fathi, M.; Sharifian, M.; Shokri, B.

    2018-03-01

    The beam produced by a thermionic RF gun has wide energy spread that makes it unsuitable for direct usage in photon sources. Here in the present work, we optimize the extracted beam from a thermionic RF gun by a compact economical bunch compressor. A compact magnetic bunch compressor (Alpha magnet) is designed and constructed. A comparison between simulation results and experimental measurements shows acceptable conformity. The beam dynamics simulation results show a reduction of the energy spread as well as a compression of length less than 1 ps with 2.3 mm-mrad emittance.

  11. Variable Energy 2-MeV S-Band Linac for X-ray and Other Applications

    International Nuclear Information System (INIS)

    Howard Bender; Dave Schwellenbach; Ron Sturges; Rusty Trainham

    2008-01-01

    We will describe the design and operation of a compact, 2-MeV, S-band linear accelerator (linac) with variable energy tuning and short-pulse operation down to 15 ps with 100-A peak current. The design consists of a buncher cavity for short-pulse operation and two coupled resonator sections for acceleration. Single-pulse operation is accomplished through a fast injector system with a 219-MHz subharmonic buncher. The machine is intended to support a variety of applications, such as X-ray and electron beam diagnostic development and, recently, electron diffraction studies of phase transitions in shocked materials

  12. Variable Energy 2-MeV S-Band Linac for X-ray and Other Applications

    International Nuclear Information System (INIS)

    H. Bender; D. Schwellenbach; R. Sturges; R. Trainham

    2008-01-01

    This paper describes the design and operation of a compact, 2-MeV, S-band linear accelerator (linac) with variable energy tuning and short-pulse operation down to 15 ps with 100-A peak current. The design consists of a buncher cavity for short-pulse operation and two coupled resonator sections for acceleration. Single-pulse operation is accomplished through a fast injector system with a 219-MHz subharmonic buncher. The machine is intended to support a variety of applications, such as x-ray and electron beam diagnostic development, and recently, electron diffraction studies of phase transitions in shocked materials

  13. Long pulse, plasma cathode E-gun

    International Nuclear Information System (INIS)

    Goebel, D.M.; Schumacher, R.W.; Watkins, R.M.

    1993-01-01

    A unique, long-pulse E-gun has been developed for high-power tube applications. The Hollow-Cathode-Plasma (HCP) E-gun overcomes the limitations of conventional thermionic-cathode guns that have limited current density (typically ≤ 10 A/cm 2 ) or field-emission guns that offer high current density but suffer from short pulsewidth capability (typically 50 A/cm 2 ), long-pulse operation without gap closure, and also requires no cathode-heater power. The gun employs a low-pressure glow discharge inside a hollow cathode (HC) structure to provide a stable, uniform plasma surface from which a high current-density electron beam can be extracted. The plasma density is controlled by a low-voltage HC discharge pulser to produce the desired electron current density at the first grid of a multi-grid accelerator system. A dc high-voltage electron-beam supply accelerates the electrons across the gap, while the HC pulser modulates the beam current to generate arbitrary pulse waveforms. The electron accelerator utilizes a multi-aperture array that produces a large area, high perveance (>35 μpervs) beam consisting initially of many individual beamlets. The E-beam is normally operated without an applied magnetic field in the ion-focused regime, where the plasma produced by beam ionization of a background gas space-charge neutralizes the beam, and the Bennett self-pinch compresses the beamlets and increases the current density. The self-pinched beam has been observed to propagate over a meter without beam breakup or instabilities. The HCP E-gun has been operated at voltages up to 150 kV, currents up to 750 A, and pulse lengths of up to 120 μsec

  14. Testing a GaAs cathode in SRF gun

    International Nuclear Information System (INIS)

    Wang, E.; Kewisch, J.; Ben-Zvi, I.; Burrill, A.; Rao, T.; Wu, Q.; Holmes, D.

    2011-01-01

    RF electron guns with a strained superlattice GaAs cathode are expected to generate polarized electron beams of higher brightness and lower emittance than do DC guns, due to their higher field gradient at the cathode's surface and lower cathode temperature. We plan to install a bulk GaAs:Cs in a SRF gun to evaluate the performance of both the gun and the cathode in this environment. The status of this project is: In our 1.3 GHz 1/2 cell SRF gun, the vacuum can be maintained at nearly 10 -12 Torr because of cryo-pumping at 2K. With conventional activation of bulk GaAs, we obtained a QE of 10% at 532 nm, with lifetime of more than 3 days in the preparation chamber and have shown that it can survive in transport from the preparation chamber to the gun. The beam line has been assembled and we are exploring the best conditions for baking the cathode under vacuum. We report here the progress of our test of the GaAs cathode in the SRF gun. Future particle accelerators, such as eRHIC and the ILC require high-brightness, high-current polarized electrons. Strained superlattice GaAs:Cs has been shown to be an efficient cathode for producing polarized electrons. Activation of GaAs with Cs,O(F) lowers the electron affinity and makes it energetically possible for all the electrons, excited into the conduction band that drift or diffuse to the emission surface, to escape into the vacuum. Presently, all operating polarized electron sources, such as the CEBAF, are DC guns. In these devices, the excellent ultra-high vacuum extends the lifetime of the cathode. However, the low field gradient on the photocathode's emission surface of the DC guns limits the beam quality. The higher accelerating gradients, possible in the RF guns, generate a far better beam. Until recently, most RF guns operated at room temperature, limiting the vacuum to ∼10 -9 Torr. This destroys the GaAs's NEA surface. The SRF guns combine the excellent vacuum conditions of DC guns and the high accelerating

  15. Stability and performance studies of the PITZ photoelectron gun

    International Nuclear Information System (INIS)

    Isaev, Igor

    2018-02-01

    The invention of free electron lasers (FELs) opened new opportunities for the investigation of natural phenomena. However, the operation of a FEL requires high energy, high peak current electron beams with very small transverse emittance which causes extreme requirements for the corresponding electron sources. Besides the high beam quality, the electron sources must have very high operational stability and reliability. One of the electron source types which satisfy FEL requirements is a photoelectron gun. Photoelectron guns combine photoemissive electron generation and direct acceleration in a Radio Frequency (RF) cavity. The Photo Injector Test facility at DESY, Zeuthen site (PITZ), was established as a test stand of the electron source for FELs like FLASH and the European XFEL in Hamburg. The studies of the beam emittance at PITZ showed that the gun is able to produce electron beams with emittance even smaller than it is required by XFEL specifications. But the experiments on the emittance revealed discrepancies between expected gun behavior and observation, such as the difference in optimal parameters for the smallest emittance value, asymmetry of the transverse beam profile and the phase spaces. The work performed at PITZ includes preparation of several RF guns for their subsequent operation at FLASH and the European XFEL. RF conditioning of a gun cavity is one of the major steps of the preparation of a high brightness electron source required for modern FELs. A thorough procedure is applied to increase the peak and average RF power in the gun cavity, including an increase of the repetition rate and RF pulse length combined with a gun solenoid current sweep. The main goals of this thesis are: (1) an attempt of deep understanding of physical processes taking place during operation of a photoelectron gun (conditioning process, parameters adjustments); (2) definition of operational problems sources and explanation of the experimentally obtained results in the gun

  16. Stability and performance studies of the PITZ photoelectron gun

    Energy Technology Data Exchange (ETDEWEB)

    Isaev, Igor

    2018-02-15

    The invention of free electron lasers (FELs) opened new opportunities for the investigation of natural phenomena. However, the operation of a FEL requires high energy, high peak current electron beams with very small transverse emittance which causes extreme requirements for the corresponding electron sources. Besides the high beam quality, the electron sources must have very high operational stability and reliability. One of the electron source types which satisfy FEL requirements is a photoelectron gun. Photoelectron guns combine photoemissive electron generation and direct acceleration in a Radio Frequency (RF) cavity. The Photo Injector Test facility at DESY, Zeuthen site (PITZ), was established as a test stand of the electron source for FELs like FLASH and the European XFEL in Hamburg. The studies of the beam emittance at PITZ showed that the gun is able to produce electron beams with emittance even smaller than it is required by XFEL specifications. But the experiments on the emittance revealed discrepancies between expected gun behavior and observation, such as the difference in optimal parameters for the smallest emittance value, asymmetry of the transverse beam profile and the phase spaces. The work performed at PITZ includes preparation of several RF guns for their subsequent operation at FLASH and the European XFEL. RF conditioning of a gun cavity is one of the major steps of the preparation of a high brightness electron source required for modern FELs. A thorough procedure is applied to increase the peak and average RF power in the gun cavity, including an increase of the repetition rate and RF pulse length combined with a gun solenoid current sweep. The main goals of this thesis are: (1) an attempt of deep understanding of physical processes taking place during operation of a photoelectron gun (conditioning process, parameters adjustments); (2) definition of operational problems sources and explanation of the experimentally obtained results in the gun

  17. High Velocity Gas Gun

    Science.gov (United States)

    1988-01-01

    A video tape related to orbital debris research is presented. The video tape covers the process of loading a High Velocity Gas Gun and firing it into a mounted metal plate. The process is then repeated in slow motion.

  18. Gun Dynamics Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Gun Dynamics Laboratory is a research multi-task facility, which includes two firing bays, a high bay area and a second floor laboratory space. The high bay area...

  19. Gun control saves lives.

    Science.gov (United States)

    Matzopoulos, Richard

    2016-05-19

    Reducing firearm mortality by means of stricter gun control is one of the most important short- to medium-term measures to address the burden of violence in South Africa, while longer-term interventions and policy measures take effect.

  20. Teen Suicide and Guns

    Science.gov (United States)

    ... Issues Listen Text Size Email Print Share Teen Suicide and Guns Page Content Article Body Protect Your ... of a passing problem, not the outcome! Teen Suicide—A Big Problem Suicide is one of the ...

  1. Gas gun dynamics

    International Nuclear Information System (INIS)

    Denny, Mark

    2013-01-01

    The mechanics and thermodynamics of one- and two-stage gas guns are developed. Very high projectile muzzle speed can be obtained by the two-stage version. The physics of simple gas guns, such as air rifles, is accessible to undergraduates and the same level of presentation is used here to understand more complex designs. Numerical solutions to the equations of motion are shown, along with insightful analytic approximations. (paper)

  2. Electron Beam Generation in Tevatron Electron Lenses

    International Nuclear Information System (INIS)

    Kamerdzhiev, V.; Kuznetsov, G.; Shiltsev, V.; Solyak, N.; Tiunov, M.

    2006-01-01

    New type of high perveance electron guns with convex cathode has been developed. Three guns described in this article are built to provide transverse electron current density distributions needed for Electron Lenses for beam-beam compensation in the Tevatron collider. The current distribution can be controlled either by the gun geometry or by voltage on a special control electrode located near cathode. We present the designs of the guns and report results of beam measurements on the test bench. Because of their high current density and low transverse temperature of electrons, electron guns of this type can be used in electron cooling and beam-beam compensation devices

  3. Electron beam generation in Tevatron electron lenses

    International Nuclear Information System (INIS)

    Kamerdzhiev, V.; Kuznetsov, G.; Shiltsev, V.; Solyak, N.; Tiunov, M.

    2006-01-01

    New type of high perveance electron guns with convex cathode has been developed. Three guns described in this article are built to provide transverse electron current density distributions needed for Electron Lenses for beam-beam compensation in the Tevatron collider. The current distribution can be controlled either by the gun geometry or by voltage on a special control electrode located near cathode. We present the designs of the guns and report results of beam measurements on the test bench. Because of their high current density and low transverse temperature of electrons, electron guns of this type can be used in electron cooling and beam-beam compensation devices

  4. Optimization of Beam Transmission of PAL-PNF Electron Linac

    Energy Technology Data Exchange (ETDEWEB)

    Shin, S. G.; Kim, S. K.; Kim, E. A. [Pohang University of Science and Technology, Pohang (Korea, Republic of)

    2012-05-15

    The PNF (Pohang Neutron Facility) electron Linac is providing converted neutrons and photons from electron beams to users for nuclear physics experiments and high energy gamma-ray exposures. This linac is capable of producing 100 MeV electron beams with a beam current of pulsed 100 mA. The pulse length is 2 {mu}s and the pulse repetition rate is typically 30 Hz. This linac consists of two SLAC-type S-band accelerating columns and the thermionic RF gun. They are powered by one klystron and the matching pulse modulator. The electron beams emitted from the RF gun are bunched as they pass through the alpha magnet and are injected into the accelerating column thereafter. In this paper, we discuss procedures and results of the beam transmission optimization with technical details of the accelerator system. We also briefly discuss the future upgrade plan to obtain short-pulse or electron beams for neutron TOF experiments by adopting a triode type thermionic DC electron gun

  5. Improved DC Gun and Insulator Assembly

    Energy Technology Data Exchange (ETDEWEB)

    Neubauer, Michael [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)

    2015-01-11

    Many user facilities such as synchrotron radiation light sources and free electron lasers rely on DC high voltage photoguns with internal field gradients as high as 10 to 15 MV/m. These high gradients often lead to field emission which poses serious problems for the photocathode used to generate the electron beam and the ceramic insulators used to bias the photocathode at high voltage. Ceramic insulators are difficult to manufacture, require long commissioning times, and have poor reliability, in part because energetic electrons bury themselves in the ceramic causing a buildup of charge and eventual puncture, and also because large diameter ceramics are difficult to braze reliably. The lifetimes of photo cathodes inside high current DC guns exhibiting field emission are limited to less than a hundred hours. Reducing the surface gradients on the metals reduces the field emission, which serves to maintain the required ultrahigh vacuum condition. A novel gun design with gradients around 5 MV/m and operating at 350 kV, a major improvement over existing designs, was proposed that allows for the in-situ replacement of photo cathodes in axially symmetric designs using inverted ceramics. In this project, the existing JLAB CEBAF asymmetric gun design with an inverted ceramic support was modeled and the beam dynamics characterized. An improved structure was designed that reduces the surface gradients and improves the beam optics. To minimize the surface gradients, a number of electrostatic gun designs were studied to determine the optimum configuration of the critical electrodes within the gun structure. Coating experiments were carried out to create a charge dissipative coating for cylindrical ceramics. The phase II proposal, which was not granted, included the design and fabrication of an axially symmetric DC Gun with an inverted ceramic that would operate with less than 5 MV/m at 350 kV and would be designed with an in-situ replaceable photo-cathode.

  6. Progress on Using NEA Cathodes in an RF Gun

    CERN Document Server

    Fliller, Raymond P; Blüm, Hans; Edwards, Helen; Hüning, Markus; Schultheiss, Tom; Sinclair, Charles K

    2005-01-01

    RF guns have proven useful in multiple accelerator applications, and are an attractive electron source for the ILC. Using a NEA GaAs photocathode in such a gun allows for the production of polarized electron beams. However the lifetime of a NEA cathode in this environment is reduced by ion and electron bombardment and residual gas oxidation. We report progress made with studies to produce a RF gun using a NEA GaAs photocathode to produce polarized electron beams. Attempts to reduce the residual gas pressure in the gun are discussed. Initial measurements of ion flux through the cathode port are compared with simulations of ion bombardment. Future directions are also discussed.

  7. 1.5-GW S-band relativistic klystron amplifier

    Science.gov (United States)

    Ferguson, Patrick E.

    1992-04-01

    There is a strong symbiotic relationship between a developing technology and its applications. New technologies can generate applications previously either unrealizable or impractical. Conversely, applications can demand the development of new technological capability. Examples of both types of development can be found in the evolution of HPM. The high power and energy output made possible by HPM have created a technology driven interest in directed energy weapons and short pulse radar. On the other hand, the requirements for heating of fusion plasmas have resulted in an application driven program to develop high average power microwave devices. In this paper we address these and other applications such as RF electron linacs, laser pumping, and beaming of power. Emerging applications, such as ionispheric modification and environmental cleanup, are also touched upon. The approach of this paper will be to review each application separately and then compare the requirements of the applications in terms of the power, frequency and other key requirements necessary for HPM to usefully address the application.

  8. GPM GROUND VALIDATION NASA S-BAND DUAL POLARIMETRIC (NPOL) DOPPLER RADAR IFLOODS V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GPM Ground Validation NASA S-Band Dual Polarimetric (NPOL) Doppler Radar IFloodS data set was collected from April 30, 2013 to June 16, 2013 near Traer, Iowa as...

  9. GPM GROUND VALIDATION NOAA S-BAND PROFILER ORIGINAL DWELL DATA MC3E V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The S-band Profiler Original Dwell dataset in the netCDF format was gathered during the Midlatitude Continental Convective Clouds Experiment (MC3E) in Oklahoma...

  10. GPM GROUND VALIDATION NOAA S-BAND PROFILER MINUTE DATA MC3E V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GPM Ground Validation NOAA S-Band Profiler Minute Data MC3E dataset was gathered during the Midlatitude Continental Convective Clouds Experiment (MC3E) in...

  11. Theoretical approach of the photoinjector exit aperture influence on the wake field driven by an electron beam accelerated in an RF gun of free-electron laser 'ELSA'

    CERN Document Server

    Salah, W

    2000-01-01

    The wake field generated in the cylindrical cavity of an RF photoinjector, by a strongly accelerated electron beam, has been analytically calculated (Salah, Dolique, Nucl. Instr. and Meth. A 437 (1999) 27) under the assumption that the perturbation of the field map by the exit hole is negligible as long as the ratio: exit hole radius/cavity radius is lower than approximately 1/3. Shown experimentally in the different context of a long accelerating structure formed by a sequence of bored pill-box cavity (Figuera et al., Phys. Rev. Lett. 60 (1988) 2144; Kim et al., J. Appl. Phys. 68 (1990) 4942), this often-quoted result must be checked for the wake field map excited in a photo injector cavity. Further, in the latter case, the empirical rule in question can be broken more easily because, due to causality, the cavity radius to be considered is not the physical radius but that of the part of the anode wall around the exit hole reached by the beam electromagnetic influence. We present an analytical treatment of th...

  12. Design and analysis of a radio frequency extractor in an S-band relativistic klystron amplifier

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Zehai; Zhang Jun; Shu Ting; Qi Zumin [College of Optoelectronic Science and Engineering, National University of Defense Technology, Changsha, Hunan 410073 (China)

    2012-09-15

    A radio frequency (RF) extractor converts the energy of a strongly modulated intense relativistic electron beam (IREB) into the energy of high power microwave in relativistic klystron amplifier (RKA). In the aim of efficiently extracting the energy of the modulated IREB, a RF extractor with all round coupling structure is proposed. Due to the all round structure, the operating transverse magnetic mode can be established easily and its resonant property can be investigated with an approach of group delay time. Furthermore, the external quality factor can be low enough. The design and analysis of the extractor applied in an S-band RKA are carried out, and the performance of the extractor is validated with three-dimensional (3D) particle-in-cell simulations. The extraction efficiency reaches 27% in the simulation with a totally 3D model of the whole RKA. The primary experiments are also carried out and the results show that the RF extractor with the external quality factor of 7.9 extracted 22% of the beam power and transformed it into the high power microwave. Better results are expected after the parasitic mode between the input and middle cavities is suppressed.

  13. Design and analysis of a radio frequency extractor in an S-band relativistic klystron amplifier

    Science.gov (United States)

    Zhang, Zehai; Zhang, Jun; Shu, Ting; Qi, Zumin

    2012-09-01

    A radio frequency (RF) extractor converts the energy of a strongly modulated intense relativistic electron beam (IREB) into the energy of high power microwave in relativistic klystron amplifier (RKA). In the aim of efficiently extracting the energy of the modulated IREB, a RF extractor with all round coupling structure is proposed. Due to the all round structure, the operating transverse magnetic mode can be established easily and its resonant property can be investigated with an approach of group delay time. Furthermore, the external quality factor can be low enough. The design and analysis of the extractor applied in an S-band RKA are carried out, and the performance of the extractor is validated with three-dimensional (3D) particle-in-cell simulations. The extraction efficiency reaches 27% in the simulation with a totally 3D model of the whole RKA. The primary experiments are also carried out and the results show that the RF extractor with the external quality factor of 7.9 extracted 22% of the beam power and transformed it into the high power microwave. Better results are expected after the parasitic mode between the input and middle cavities is suppressed.

  14. Electromagnetic Guns versus Conventional Guns - a performance comparison

    NARCIS (Netherlands)

    Reus, N.M. de; Weijden, J. van der

    1993-01-01

    Performance improvement is one of the key issues of Electromagnetic gun systems compared to conventional gun systems. Due to higher muzzle velocities, the gun's fire control computer will be able to predict the target's future position more accurately because prediction time will be smaller. In this

  15. A microscopic study of the S band in the generator co-ordinate approach

    International Nuclear Information System (INIS)

    Wuest, E.; Ansari, A.

    1985-04-01

    Using particle number and spin projected cranked Hartree-Fock-Bogolubov (CHFB) wave functions in the generator co-ordinate method (GCM) with the cranking frequency as a GC the shortcomings of the usual CHFB theory are removed and the ground as well as the s band are studied simultaneously. In particular, low-spin properties of the s band are discussed for a backbending nucleus 158 Dy. (author)

  16. High Brightness Injectors Based On Photocathode DC Gun

    International Nuclear Information System (INIS)

    B. Yunn

    2001-01-01

    Sample results of new injector design method based on a photocathode dc gun are presented, based on other work analytically proving the validity of the emittance compensation scheme for the case even when beam bunching is involved. We have designed several new injectors appropriate for different bunch charge ranges accordingly. Excellent beam quality produced by these injectors clearly shows that a photocathode dc gun can compete with a rf gun on an equal footing as the source of an electron beam for the bunch charge ranging up to 2 nano Coulomb (nC). This work therefore elevates a dc gun based injector to the preferred choice for many ongoing high brightness accelerator projects considering the proven operational stability and high average power capability of the dc gun

  17. Fueling by coaxial plasma guns

    International Nuclear Information System (INIS)

    Marshall, J.

    1978-01-01

    The operating principles of pulsed coaxial guns are reviewed. Some problems involved with the injection of plasma beams from these guns into containment fields are described. The injection during reactor operating conditions is then discussed

  18. A 3 GHz photoelectron gun for high beam intensity

    CERN Document Server

    Bossart, Rudolf; Dehler, M; Godot, J C

    1996-01-01

    For the Compact Linear Collider Test Facility (CTF) at CERN a new rf gun with a laser driven photocathode is under construction. The new rf gun will replace the present 11/2 cell gun and will consist of 21/2 cells accelerating the beam to a momentum of 7.0 MeV/c with an electric field strength of 100 MV/m. The strong space-charge forces at low beam energy caused by the high charge density of the electron bunches are contained by radial and longitudinal rf focusing in the gun. The rf gun under construction has been optimized by MAFIA beam simulations for an injector assembly comprising a second accelerating rf structure and an intermediate solenoid magnet correcting the beam divergence of the 21/2 cell gun. The beam loading of the rf gun, by a train of 48 bunches with 21 nC charge each, causes a strong energy decay accompanied by an increase of the flight time for the bunches with lower energy. These effects can be corrected by slightly shifting the acceleration frequency of the gun. The experimental results...

  19. Glue Guns: Aiming for Safety

    Science.gov (United States)

    Roy, Ken

    2010-01-01

    While glue guns are very useful, there are safety issues. Regardless of the temperature setting, glue guns can burn skin. The teacher should demonstrate and supervise the use of glue guns and have a plan should a student get burned. There should be an initial first aid protocol in place, followed by a visit to the school nurse. An accident report…

  20. Development of low emittance high brightness electron beams and rf accelerating structures

    International Nuclear Information System (INIS)

    Pellegrini, C.

    1991-01-01

    The main goals of this project were the construction of an S-band RF photoinjector for the production of a high brightness electron beam, and the development of a new type of RF accelerator structure; the Plane wave transformer. By the end of October 1991 the photoinjector had been built, its RF characteristics had been measured at low power, and an initial test of the gun at high RF power had been done. The Plane Wave Transformer had also been built and tested at lower power. In both cases the results obtained are mostly in agreement with the expected and calculated behavior