WorldWideScience

Sample records for guided core needle

  1. Ultrasound-guided fine needle aspiration versus core needle biopsy: comparison of post-biopsy hematoma rates and risk factors.

    Science.gov (United States)

    Chae, In Hye; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; Park, Vivian Y; Kwak, Jin Young

    2017-07-01

    To compare post-biopsy hematoma rates between ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy, and to investigate risk factors for post-biopsy hematoma. A total of 5304 thyroid nodules which underwent ultrasound guided biopsy were included in this retrospective study. We compared clinical and US features between patients with and without post-biopsy hematoma. Associations between these features and post-biopsy hematoma were analyzed. Post-biopsy hematoma rate was 0.8% (43/5121) for ultrasound guided-fine needle aspiration and 4.9% (9/183) for ultrasound guided-core needle biopsy (P core needle biopsy (9/179, 5.0%) than with ultrasound guided-fine needle aspiration (9/1138, 0.8%) (P core needle biopsy was the only significant risk factor for post-biopsy hematoma (adjusted Odds Ratio, 6.458, P core needle biopsy than in ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy was the only independent factor of post-biopsy hematoma in thyroid nodules.

  2. Ultrasound-guided core needle biopsy for breast cancer

    International Nuclear Information System (INIS)

    Naqvi, S.Q.H.; Solangi, R.A.; Memon, M.; Solangi, R.A.

    2008-01-01

    To evaluate the efficacy of ultrasound-guided core needle biopsy (US-CNB) as a preoperative diagnostic modality for breast cancer. Females with solid and/or intermediate breast lesions visualized on ultrasonography. Apart from clinical work-up, all the above mentioned patients underwent ultrasound-guided core needle biopsy and excisional biopsy of their breast lesions. The histopathological diagnosis on ultrasound-guided core needle biopsy was then compared with the findings of the excisional biopsy. Out of the total 93 cases, 47(50.5%) had benign lesions on ultrasound; US-CNB showed 24 as fibroadenomata, four with chronic non-specific mastitis, five chronic suppurative mastitis, one tuberculosis, four fat necrosis, two lactational adenoma and seven cases with benign ductal hyperplasia without atypia. Nine (9.7%) cases showed suspicious abnormality on ultrasound; US-CNB revealed five cases with atypical ductal hyperplasia, one ductal carcinoma in situ and three invasive ductal carcinoma. Thirty seven (39.8%) cases were highly suggestive of malignancy on ultrasound; US-CNB showed 34 as invasive ductal carcinoma, two invasive lobular and one medullary carcinoma. Excisional biopsy confirmed the diagnosis of ultrasound-guided core needle biopsy in all cases except four; one case of chronic suppurative mastitis was diagnosed as that of tuberculosis and three cases of atypial ductal hyperplasia as invasive ductal carcinoma. Hence there was no false positive case, but four (4.3%) false negative cases. The sensitivity of the US-CNB was thus 100% and specificity 91.1%. Ultrasound guided core needle biopsy is a satisfactory procedure for the histopathological diagnosis of breast lesions. Any unsatisfactory, suspicious or atypical change on US-CNB should be followed by an open biopsy. (author)

  3. CT-guided core-needle biopsy in omental pathology

    International Nuclear Information System (INIS)

    Pombo, F.; Rodriguez, E.; Martin, R.; Lago, M.

    1997-01-01

    Purpose: To assess the accuracy and clinical usefulness of CT-guided core-needle biopsy in the diagnosis of omental pathology. Material and Methods: We retrospectively reviewed the results of CT-guided percutaneous core biopsies in 25 patients with focal (n=2) or diffuse (n=23) omental pathology. These results were compared to the final diagnoses as determined by laparotomy (n=15), laparoscopic biopsy (n=3), endoscopic biopsy (n=1), or by the results of percutaneous biopsy and clinical-radiological and bacteriological modalities (n=6). The final diagnoses showed 4 patients with isolated omental pathology and 21 with widespread peritoneal involvement. The CT-guided biopsies were performed with 1.0=1.8-mm Surecut core-needles. Results: In 16 patients, the final diagnosis was metastatic adenocarcinoma - with the primary tumor sites in the ovary (n=3), stomach (n=1), appendix (n=2), and unknown (n=10). In the remaining 9 patients, the final diagnosis was hepatocellular carcinoma, lymphoma, and mesothelioma in 1 patient each; tuberculosis in 5; and actinomycosis in 1. Sufficient histological (n=16) or cytological (n=8) material was obtained by CT biopsy in 24/25 (96%) cases; the specimen was insufficient for diagnosis in 1 case. In differentiating benign from malignant disease, CT-guided biopsy showed a sensitivity, specificity and accuracy of respectively 89.5%, 100% and 92%. It gave a specific diagnosis in 78.9% (15/19) of patients with malignant conditions and in 50% (3/6) of patients with benign disorders. There were no biopsy-related complications. Conclusion: CT-guided percutaneous core-needle biopsy of the omentum is a safe, useful and highly accurate procedure for diagnosing malignant omental pathology. (orig.)

  4. A comparison of ultrasound guided fine needle aspiration cytology and core needle biopsy in evaluation of palpable breast lesions

    International Nuclear Information System (INIS)

    Altaf, H.N.; Farooqui, F.

    2015-01-01

    Objective: To compare ultrasound guided fine-needle aspiration cytology (FNAC) and core needle biopsy (CNB) in patients presenting with palpable breast lumps (PBLs), in terms of sensitivity and specificity, taking final histopathology as gold standard. Methodology: This cross-sectional study was conducted at Holy Family Hospital, Rawalpindi, Pakistan. Ultrasound guided FNAC and CNB were taken of all female patients with PBLs. The results were compared with final histopathology as gold standard. Data analysis was performed using SPSS software and chi-square test. Results: A total of 60 patients were included in the study. The mean age was 33.8 yrs. The sensitivity and specificity of ultrasound guided FNAC were 68.7% and 93.1%, respectively. The sensitivity and specificity of ultrasound guided CNB was 93.7% and 100%. The accuracy of FNAC was 86.2% and that of core needle biopsy was 98.3%. Conclusion: The ultrasound guided core needle biopsy can be used as an initial diagnostic test for the evaluation of all PBLs. Because of high negative predictive value core needle biopsy can replace surgical excision biopsy for benign lesions. (author)

  5. The efficacy of an ultrasound-guided core needle biopsy with an 18G cutting needle for the diagnosis of pancreatic diseases

    International Nuclear Information System (INIS)

    Jung, Sung Hwa; Park, Won Kyu; Chang, Jay Chun; Kim, Jae Woon; Cho, Jae Ho; Jang, Han Won; Lee, Jae Kyo; Choi, Joon Hyuk

    2008-01-01

    The objective of this study is to evaluate the efficacy and safety of an ultrasound-guided core needle biopsy with an 18G cutting needle in patients suspected of having a pancreatic disease by analyzing the diagnostic performance and complication rate. The study population comprised 35 consecutive patients who underwent an ultrasound-guided core needle biopsy using a high-speed biopsy gun accompanied with an 18G cutting-type needle between May of 2001 and October of 2005. The diagnostic performance (i.e., the acquisition rate and diagnostic accuracy) and complications associated with core needle biopsies were evaluated for its efficacy and safety. Thirty-six sessions of ultrasound-guided core needle biopsies were performed in 35 consecutive patients. All patients, except two (serous cystadenoma and autoimmune pancreatitis) were diagnosed with various subtypes of pancreatic cancer. The acquisition rate and diagnostic accuracy were 97% (35/36) and 94% (34/36), respectively. A complication occurred only in one patient (3%), which further proved to be a delayed complication (i.e., needle tract implantation). According to our findings, the ultrasound-guided core needle biopsy is a viable and safe method for the diagnosis of pancreatic diseases. Moreover, it enables the diagnosis of the pancreatic cancer subtype

  6. Ultrasound-guided percutaneous core needle biopsy of splenic lesions

    Energy Technology Data Exchange (ETDEWEB)

    Park, SangIk; Shin, Yong Moon; Won, Hyung Jin; Kim, Pyo Nyun; Lee, Moon Gyu [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2017-05-15

    To evaluate the safety and efficacy of ultrasound-guided percutaneous core needle biopsy of splenic lesions. This retrospective study included 30 patients who underwent percutaneous core needle biopsy of their splenic lesions using 18- or 20-gauge needles between January 2001 and July 2016 in a single tertiary care center. The characteristics of the splenic lesions were determined by reviewing the ultrasound and computed tomography examinations. Acquisition rate and diagnostic accuracy were calculated, using pathologic results of the splenectomy specimen, clinical course and/or imaging follow-up as a reference standard. Post-procedure complications were identified from electronic medical records, laboratory findings and computed tomography images. Seventy-three specimens were obtained from the 30 patients and splenectomy was performed in 2 patients. Twenty-nine of the 30 patients had focal splenic lesions, while the remaining patient had homogeneous splenomegaly. Acquisition rate and diagnostic accuracy were 80.0% (24/30) and 76.7% (23/30), respectively. Perisplenic hemorrhage without hemodynamic instability developed in one patient. Ultrasound-guided percutaneous core needle biopsy of splenic lesions is a safe method for achieving a histopathologic diagnosis and can be considered as an alternative to splenectomy in patients with a high risk of splenectomy-related complications.

  7. Ultrasound-guided percutaneous core needle biopsy of splenic lesions

    International Nuclear Information System (INIS)

    Park, SangIk; Shin, Yong Moon; Won, Hyung Jin; Kim, Pyo Nyun; Lee, Moon Gyu

    2017-01-01

    To evaluate the safety and efficacy of ultrasound-guided percutaneous core needle biopsy of splenic lesions. This retrospective study included 30 patients who underwent percutaneous core needle biopsy of their splenic lesions using 18- or 20-gauge needles between January 2001 and July 2016 in a single tertiary care center. The characteristics of the splenic lesions were determined by reviewing the ultrasound and computed tomography examinations. Acquisition rate and diagnostic accuracy were calculated, using pathologic results of the splenectomy specimen, clinical course and/or imaging follow-up as a reference standard. Post-procedure complications were identified from electronic medical records, laboratory findings and computed tomography images. Seventy-three specimens were obtained from the 30 patients and splenectomy was performed in 2 patients. Twenty-nine of the 30 patients had focal splenic lesions, while the remaining patient had homogeneous splenomegaly. Acquisition rate and diagnostic accuracy were 80.0% (24/30) and 76.7% (23/30), respectively. Perisplenic hemorrhage without hemodynamic instability developed in one patient. Ultrasound-guided percutaneous core needle biopsy of splenic lesions is a safe method for achieving a histopathologic diagnosis and can be considered as an alternative to splenectomy in patients with a high risk of splenectomy-related complications

  8. Accuracy of CT-guided percutaneous core needle biopsy for assessment of pediatric musculoskeletal lesions

    International Nuclear Information System (INIS)

    Hryhorczuk, Anastasia L.; Strouse, Peter J.; Biermann, J.S.

    2011-01-01

    CT-guided percutaneous core needle biopsy has been shown in adults to be an effective diagnostic tool for a large number of musculoskeletal malignancies. To characterize our experience with CT-guided percutaneous core needle biopsy of pediatric bone lesions and determine its utility in diagnosing pediatric osseous lesions, in a population where such lesions are commonly benign. From 2000 to 2009, 61 children underwent 63 CT-guided percutaneous biopsies. Radiological, pathological and clinical records were reviewed. Fourteen biopsies (22%) were performed on malignant lesions, while 49 biopsies (78%) were performed on benign lesions. Forty-nine of the 63 biopsies (78%) were adequate; these children underwent no further tissue sampling. Fourteen of the 63 biopsies (22%) were inadequate or non-conclusive. Of these patients, 12 underwent open biopsy. Retrospective analysis of percutaneous biopsies in these patients demonstrates that 9/12 provided clinically relevant information, and 4/12 patients received final diagnoses that confirmed initial core biopsy findings. No malignancies were diagnosed as benign on percutaneous biopsy. Overall, percutaneous core needle biopsy provided accurate diagnostic information in 84% (53/63) of biopsies. Our results demonstrate that CT-guided percutaneous biopsy is safe and beneficial in children. This study supports the use of CT-guided percutaneous core needle biopsy for primary diagnosis of pediatric bone lesions. (orig.)

  9. A retrospective analysis of ultrasound-guided large core needle ...

    African Journals Online (AJOL)

    A retrospective analysis of ultrasound-guided large core needle biopsies of breast lesions at a regional public hospital in Durban, KwaZulu-Natal, South Africa. ... Objective: To assess the influence of technical variables on the diagnostic yield of breast specimens obtained by using US-LCNB, and the sensitivity of detecting ...

  10. Nodular fasciitis of the face diagnosed by US-guided core needle biopsy: a case report

    International Nuclear Information System (INIS)

    Lee, Sang Kwon; Kwon, Sun Young

    2006-01-01

    We report here on a case of nodular fasciitis (NF) that was diagnosed by ultrasonography (US)-guided core needle biopsy in a 31-year-old man, and we include the US and computed tomographic (CT) findings and the histopathologic findings at US-guided core needle biopsy (CNB). We suggest that high-resolution US is useful for the detailed evaluation of NF in the superficial regions, such as the face, and US-guided CNB is useful for the definitive histologic diagnosis of NF without causing scarring

  11. Automated tru-cut imaging-guided core needle biopsy of canine ...

    African Journals Online (AJOL)

    The purpose of this study was to evaluate the diagnostic value of imaging-guided core needle biopsy for canine orbital mass diagnosis. A second excisional biopsy obtained during surgery or necropsy was used as the reference standard. A prospective feasibility study was conducted in 23 canine orbital masses at a single ...

  12. Microscopic findings in EUS-guided fine needle (SharkCore) biopsies with type 1 and type 2 autoimmune pancreatitis

    DEFF Research Database (Denmark)

    Detlefsen, Sönke; Joergensen, Maiken Thyregod; Mortensen, Michael Bau

    2017-01-01

    The International Consensus Diagnostic Criteria (ICDC) for the diagnosis of autoimmune pancreatitis (AIP) include the histological criterion that is based on either pancreatic core needle biopsies (CNBs) or surgical specimens. However, CNBs are difficult to obtain by endoscopic ultrasound (EUS......). EUS fine-needle aspiration (EUS-FNA) cytology is usually not sufficient for the diagnosis of AIP, but may sometimes contain tissue microfragments. Another approach is EUS-guided histological fine-needle biopsy (EUS-FNB), using needles such as the SharkCore or ProCore needle. Published data regarding...... EUS-guided SharkCore FNB for the diagnosis of AIP are lacking. We aimed to describe our histological findings in one type 1 and two type 2 AIP patients who underwent EUS SharkCore FNB. The EUS-FNBs of two patients fulfilled the histological level 2 ICDC for type 1 AIP or type 2 AIP. The EUS-FNB of one...

  13. Computed tomography-guided core-needle biopsy of lung lesions: an oncology center experience

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes, Marcos Duarte; Fonte, Alexandre Calabria da; Chojniak, Rubens, E-mail: marcosduarte@yahoo.com.b [Hospital A.C. Camargo, Sao Paulo, SP (Brazil). Dept. of Radiology and Imaging Diagnosis; Andrade, Marcony Queiroz de [Hospital Alianca, Salvador, BA (Brazil); Gross, Jefferson Luiz [Hospital A.C. Camargo, Sao Paulo, SP (Brazil). Dept. of Chest Surgery

    2011-03-15

    Objective: The present study is aimed at describing the experience of an oncology center with computed tomography guided core-needle biopsy of pulmonary lesions. Materials and Methods: Retrospective analysis of 97 computed tomography-guided core-needle biopsy of pulmonary lesions performed in the period between 1996 and 2004 in a Brazilian reference oncology center (Hospital do Cancer - A.C. Camargo). Information regarding material appropriateness and the specific diagnoses were collected and analyzed. Results: Among 97 lung biopsies, 94 (96.9%) supplied appropriate specimens for histological analyses, with 71 (73.2%) cases being diagnosed as malignant lesions and 23 (23.7%) diagnosed as benign lesions. Specimens were inappropriate for analysis in three cases. The frequency of specific diagnosis was 83 (85.6%) cases, with high rates for both malignant lesions with 63 (88.7%) cases and benign lesions with 20 (86.7%). As regards complications, a total of 12 cases were observed as follows: 7 (7.2%) cases of hematoma, 3 (3.1%) cases of pneumothorax and 2 (2.1%) cases of hemoptysis. Conclusion: Computed tomography-guided core needle biopsy of lung lesions demonstrated high rates of material appropriateness and diagnostic specificity, and low rates of complications in the present study. (author)

  14. Ultrasound guided percutaneous fine needle aspiration biopsy ...

    African Journals Online (AJOL)

    )-guided percutaneous fine needle aspiration biopsy (PFNAB)/US-guided percutaneous needle core biopsy (PNCB) of abdominal lesions is efficacious in diagnosis, is helpful in treatment choice, to evaluate whether various other investigations ...

  15. Accuracy of Core Needle Biopsy Versus Fine Needle Aspiration Cytology for Diagnosing Salivary Gland Tumors

    Directory of Open Access Journals (Sweden)

    In Hye Song

    2015-03-01

    Full Text Available Background: Core needle biopsy is a relatively new technique used to diagnose salivary gland lesions, and its role in comparison with fine needle aspiration cytology needs to be refined. Methods: We compared the results of 228 ultrasound-guided core needle biopsy and 371 fine needle aspiration procedures performed on major salivary gland tumors with their postoperative histological diagnoses. Results: Core needle biopsy resulted in significantly higher sensitivity and more accurate tumor subtyping, especially for malignant tumors, than fine needle aspiration. No patient developed major complications after core needle biopsy. Conclusions: We recommend ultrasoundguided core needle biopsy as the primary diagnostic tool for the preoperative evaluation of patients with salivary gland lesions, especially when malignancy is suspected.

  16. Histopathologic quality of prostate core biopsy specimens: comparison of an MR-compatible biopsy needle and a ferromagnetic biopsy needle used for ultrasound-guided prostate biopsy

    International Nuclear Information System (INIS)

    Franiel, T.; Hamm, B.; Beyersdorff, D.; Fritzsche, F.; Staack, A.; Rost, J.

    2006-01-01

    Purpose: The histopathologic quality of core biopsy specimens obtained via MRI-guided prostate biopsy using a 16G MR-compatible needle was compared to that of biopsies obtained via ultrasound-guided biopsy using a conventional 18G stainless steel biopsy needle. Material and Methods: A retrospective analysis was performed for a total of 247 transrectal prostate biopsy specimens obtained from 32 patients. A total of 117 tissue cores were obtained from 15 patients (PSA of 10.8 ng/ml, age 64 years) who underwent an MRI-guided prostate biopsy using a 16G (1.7 mm) MR-compatible biopsy needle made of titanium alloy. The remaining 130 tissue cores were obtained from 17 patients (PSA of 6.7 ng/ml, age 68 years) who underwent a transrectal ultrasound-guided prostate biopsy using an 18G (1.3 mm) ferromagnetic stainless steel biopsy needle. The length and width of the histologic sections prepared from the tissue cores were measured to calculate the area. The histopathologic quality of the specimens was assessed microscopically using tissue fragmentation, the presence of crush artifacts, and the overall assessability as criteria. Each of these features was assigned a score from 0 to 3. All 3 features contributed equally to the overall score which ranged from 0 (no tissue) to 9 (optimal quality). Results: The overall quality scores assigned to the biopsies obtained with a 16G MR-compatible needle and an 18G ferromagnetic needle can be considered to be equivalent to a mean difference between patient related median scores of the specimens of -0.05 (95% confidence interval [-0.46; 0.36]) and a given equivalence limit of 1. The MRI biopsies showed more tissue fragmentation (p=0.001) but fewer crush artifacts (p=0.022) while the assessability did not differ significantly between the two needle types (p=0.064). There was also no significant difference in the calculated areas of the tissue cores (p=0.236). According to the different calibers of the biopsy needles, the lengths (p=0

  17. A retrospective analysis of ultrasound-guided large core needle ...

    African Journals Online (AJOL)

    2016-07-27

    Jul 27, 2016 ... The different types of non-surgical breast biopsy procedures include: fine needle aspiration biopsy. (FNAB), core needle ... needle biopsies of breast lesions at a regional public hospital in ..... NCR_2009_FINAL.pdf. 2. Parikh J ...

  18. Diagnostic accuracy of 22/25-gauge core needle in endoscopic ultrasound-guided sampling: systematic review and meta-analysis.

    Science.gov (United States)

    Oh, Hyoung-Chul; Kang, Hyun; Lee, Jae Young; Choi, Geun Joo; Choi, Jung Sik

    2016-11-01

    To compare the diagnostic accuracy of endoscopic ultrasound-guided core needle aspiration with that of standard fine-needle aspiration by systematic review and meta-analysis. Studies using 22/25-gauge core needles, irrespective of comparison with standard fine needles, were comprehensively reviewed. Pooled sensitivity, specificity, diagnostic odds ratio (DOR), and summary receiver operating characteristic curves for the diagnosis of malignancy were used to estimate the overall diagnostic efficiency. The pooled sensitivity, specificity, and DOR of the core needle for the diagnosis of malignancy were 0.88 (95% confidence interval [CI], 0.84 to 0.90), 0.99 (95% CI, 0.96 to 1), and 167.37 (95% CI, 65.77 to 425.91), respectively. The pooled sensitivity, specificity, and DOR of the standard needle were 0.84 (95% CI, 0.79 to 0.88), 1 (95% CI, 0.97 to 1), and 130.14 (95% CI, 34.00 to 495.35), respectively. The area under the curve of core and standard needle in the diagnosis of malignancy was 0.974 and 0.955, respectively. The core and standard needle were comparable in terms of pancreatic malignancy diagnosis. There was no significant difference in procurement of optimal histologic cores between core and standard needles (risk ratio [RR], 0.545; 95% CI, 0.187 to 1.589). The number of needle passes for diagnosis was significantly lower with the core needle (standardized mean difference, -0.72; 95% CI, -1.02 to -0.41). There were no significant differences in overall complications (RR, 1.26; 95% CI, 0.34 to 4.62) and technical failure (RR, 5.07; 95% CI, 0.68 to 37.64). Core and standard needles were comparable in terms of diagnostic accuracy, technical performance, and safety profile.

  19. CT-guided core biopsy of malignant lung lesions: how many needle passes are needed?

    International Nuclear Information System (INIS)

    Lim, Chaehun; Han, Dae Hee; Lee, Kyo Young; Kim, Young Kyoon; Ko, Jeong Min

    2013-01-01

    The study aims to determine the number of needle pass in the CT-guided core needle biopsy (CNB) in making a diagnosis of pulmonary malignancy. A total of 434 CNB records were retrospectively reviewed. The specimen obtained from each needle pass was put in a formalin container and then labelled for separate histopathological reporting. The patients were divided into five groups according to the total number of needle passes (n=1, n=2, n=3, n=4 and n≥5). In each of the groups 2–4, it was analysed how many needle passes are required before a plateau in diagnostic yield is achieved. CNB produced 283 true-positive and 23 false-negative diagnosis of malignancy. Cumulative sensitivity significantly (P<0.05) increased between the first and second as well as the second and the third (if done) needle passes, but not between the third and fourth ones. Three coaxial needle passes might be optimal in the diagnosis of lung malignancy.

  20. Percutaneous computed tomography-guided core needle biopsy of soft tissue tumors: results and correlation with surgical specimen analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chojniak, Rubens; Grigio, Henrique Ramos; Bitencourt, Almir Galvao Vieira; Pinto, Paula Nicole Vieira; Tyng, Chiang J.; Cunha, Isabela Werneck da; Aguiar Junior, Samuel; Lopes, Ademar, E-mail: chojniak@uol.com.br [Hospital A.C. Camargo, Sao Paulo, SP (Brazil)

    2012-09-15

    Objective: To evaluate the efficacy of percutaneous computed tomography (CT)-guided core needle biopsy of soft tissue tumors in obtaining appropriate samples for histological analysis, and compare its diagnosis with the results of the surgical pathology as available. Materials and Methods: The authors reviewed medical records, imaging and histological reports of 262 patients with soft-tissue tumors submitted to CT-guided core needle biopsy in an oncologic reference center between 2003 and 2009. Results: Appropriate samples were obtained in 215 (82.1%) out of the 262 patients. The most prevalent tumors were sarcomas (38.6%), metastatic carcinomas (28.8%), benign mesenchymal tumors (20.5%) and lymphomas (9.3%). Histological grading was feasible in 92.8% of sarcoma patients, with the majority of them (77.9%) being classified as high grade tumors. Out of the total sample, 116 patients (44.3%) underwent surgical excision and diagnosis confirmation. Core biopsy demonstrated 94.6% accuracy in the identification of sarcomas, with 96.4% sensitivity and 89.5% specificity. A significant intermethod agreement about histological grading was observed between core biopsy and surgical resection (p < 0.001; kappa = 0.75). Conclusion: CT-guided core needle biopsy demonstrated a high diagnostic accuracy in the evaluation of soft tissue tumors as well as in the histological grading of sarcomas, allowing an appropriate therapeutic planning (author)

  1. Comparison of Histologic Core Portions Acquired from a Core Biopsy Needle and a Conventional Needle in Solid Mass Lesions: A Prospective Randomized Trial.

    Science.gov (United States)

    Lee, Ban Seok; Cho, Chang-Min; Jung, Min Kyu; Jang, Jung Sik; Bae, Han Ik

    2017-07-15

    The superiority of endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) over EUS-guided fine needle aspiration (EUS-FNA) remains controversial. Given the lack of studies analyzing histologic specimens acquired from EUS-FNB or EUS-FNA, we compared the proportion of the histologic core obtained from both techniques. A total of 58 consecutive patients with solid mass lesions were enrolled and randomly assigned to the EUS-FNA or EUS-FNB groups. The opposite needle was used after the failure of core tissue acquisition using the initial needle with up to three passes. Using computerized analyses of the scanned histologic slide, the overall area and the area of the histologic core portion in specimens obtained by the two techniques were compared. No significant differences were identified between the two groups with respect to demographic and clinical characteristics. Fewer needle passes were required to obtain core specimens in the FNB group (pcore (11.8%±19.5% vs 8.0%±11.1%, p=0.376) or in the diagnostic accuracy (80.6% vs 81.5%, p=0.935) between two groups. The proportion of histologic core and the diagnostic accuracy were comparable between the FNB and FNA groups. However, fewer needle passes were required to establish an accurate diagnosis in EUS-FNB.

  2. Ultrasound-guided core needle biopsy in diagnosis of abdominal and pelvic neoplasm in pediatric patients.

    Science.gov (United States)

    Wang, Hailing; Li, Fangxuan; Liu, Juntian; Zhang, Sheng

    2014-01-01

    Ultrasound-guided core needle biopsy of abdominal and pelvic masses in adults has gained tremendous popularity. However, the application of the same treatment in children is not as popular because of apprehensions regarding inadequate tissues for the biopsy and accidental puncture of vital organs. Data of the application of ultrasound-guided core needle biopsy in 105 pediatric patients with clinically or ultrasound-diagnosed abdominopelvic masses were reviewed. Diagnostic procedures were conducted in our institution from May 2011 to May 2013. The biopsies were conducted on 86 malignant lesions and 19 benign lesions. 86 malignant tumors comprised neuroblastomas (30 cases), hepatoblastomas (15 cases), nephroblastomas (11 cases), and primitive neuroectodermal tumors/malignant small round cells (6 cases). Among malignant tumor cases, only a pelvic primitive neuroectodermal tumor did not receive a pathological diagnosis. Therefore, the biopsy accuracy was 98.8 % in malignant tumor. However, the biopsies for one neuroblastomas and one malignant small round cell tumor were inadequate for cytogenetic analysis. Therefore, 96.5 % of the malignant tumor patients received complete diagnosis via biopsy. 19 benign tumors comprised mature teratoma (10 cases), hemangioendothelioma (3 cases), paraganglioma (2 cases), and infection (2 cases). The diagnostic accuracy for benign neoplasm was 100 %. Five patients experienced postoperative complications, including pain (2 patients), bleeding from the biopsy site (2 patients), and wound infection (1 patient). Ultrasound-guided core needle biopsy is an efficient, minimally invasive, accurate, and safe diagnostic method that can be applied in the management of abdominal or pelvic mass of pediatric patients.

  3. CT-guided core needle biopsy of mediastinal nodes through a transpulmonary approach: retrospective analysis of the procedures conducted over six years.

    Science.gov (United States)

    Yin, Zhongyuan; Liang, Zhiwen; Li, Pengcheng; Wang, Qiong

    2017-08-01

    To retrospectively evaluate the diagnostic performance and complications of a CT-guided core needle cutting biopsy of mediastinal nodes through a transpulmonary approach. From January 2009 to December 2014, we used a coaxial positioning system and an 18G cutting-type biopsy device to perform CT-guided percutaneous transpulmonary needle biopsies of mediastinal nodes for 127 patients. The diagnostic performance, complication rate, influencing factors, distribution of mediastinal nodes and pathological diagnoses were investigated. Among 127 patients, pathologic analyses showed that all of the biopsies were technically successful. The sensitivity, specificity, positive predictive value, and negative predictive value were all 100%. As for complications, the ratios for pneumothorax and hemoptysis were 33.9% and 4.7%, respectively. Multivariate analyses revealed that the distance from the pleura to the target lesion (P = 0.008) and the numbers of visceral pleura injuries (P = 0.006) were the two most significant risk factors for pneumothorax, and that the distance from the pleura to the target lesion (P = 0.004) was the most significant risk factor for hemoptysis. CT-guided core needle cutting biopsy of mediastinal nodes through a transpulmonary approach is a safe and efficient diagnostic method. • CT-guided core needle biopsy is an accurate technique for diagnosing mediastinal nodes. • The rates of complications are similar to those for pulmonary lesion biopsy. • Pneumothorax risk factors include distance from pleura to target lesion and number of visceral pleura. • Distance from pleura to target lesion is the risk factor for hemoptysis. • CT-guided core needle biopsy is an important diagnostic method for mediastinal nodes.

  4. Computed tomography-guided percutaneous core needle biopsy of deep seated bone lesions in two dogs

    International Nuclear Information System (INIS)

    Mori, T.; Sakaida, M.; Yamada, M.; Akiyama, H.; Takai, Y.; Sakai, H.; Maruo, K.

    2006-01-01

    Computed Tomography (CT)-guided percutaneous core needle biopsies were undertaken for the diagnosis of osteosarcoma in the pelvis (case 1) and myeloma (case 2) in the seventh lumber vertebra which were difficult to targeted by palpation, ultrasound or fluoroscopy. In both cases, enough tissue for pathological diagnosis were obtained without any complication. CT-guided biopsy was thought to be a safe, easy and effective technique for the evaluation of the deep seated bone lesion

  5. Effect of Needle Size in Ultrasound-guided Core Needle Breast Biopsy: Comparison of 14-, 16-, and 18-Gauge Needles.

    Science.gov (United States)

    Giuliani, Michela; Rinaldi, Pierluigi; Rella, Rossella; Fabrizi, Gina; Petta, Federica; Carlino, Giorgio; Di Leone, Alba; Mulè, Antonino; Bufi, Enida; Romani, Maurizio; Belli, Paolo; Bonomo, Lorenzo

    2017-11-01

    The aim of the present study was to assess the diagnostic accuracy of ultrasound-guided core needle biopsy (US-CNB) of breast lesions, comparing smaller needles (16- and 18-gauge) with the 14-gauge needle, and to analyze the lesion characteristics influencing US-CNB diagnostic performance. All the patients provided informed consent before the biopsy procedure. The data from breast lesions that had undergone US-CNB in our institution from January 2011 to January 2015 were retrospectively reviewed. The inclusion criterion was the surgical histopathologic examination findings of the entire lesion or radiologic follow-up data for ≥ 24 months. The exclusion criterion was the use of preoperative neoadjuvant therapy. The US-CNB results were compared with the surgical pathologic results or with the follow-up findings in the 3 needle size groups (14-, 16-, and 18-gauge). The needle size- and lesion characteristic-specific diagnostic accuracy parameters were evaluated. Statistical analysis was performed using a dedicated software program, and P ≤ .01 was considered significant. A total of 1118 US-CNB cases (1042 patients) were included. Of the 1118 cases, 630 (56.3%) were in the 14-gauge group, 136 (12.2%) in the 16-gauge, and 352 (31.5%) in the 18-gauge needle group. Surgery was performed on 800 lesions (71.6%). Of these, 619 were malignant, 77 were high risk, and 104 were benign. The remaining 318 lesions (28.4%) underwent follow-up imaging studies. All the lesions were stable and, therefore, were considered benign. No differences were observed in the diagnostic accuracy parameters among the 3 needle size groups (P > .01). The false-negative rate was greater for lesions  .01). US-CNB performed with small needles (16 and 18 gauge) had the same diagnostic accuracy as that performed with 14-gauge needles, regardless of the lesion characteristics. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Computed Tomography-Guided Core-Needle Biopsy Specimens Demonstrate Epidermal Growth Factor Receptor Mutations in Patients with Non-Small-Cell Lung Cancer

    International Nuclear Information System (INIS)

    Chen, C.M.; Chang, J.W.C.; Cheung, Y.C.; Lin, G.; Hsieh, J.J.; Hsu, T.; Huang, S.F.

    2008-01-01

    Background: Target therapy with a new class of epidermal growth factor receptor (EGFR) inhibitors shows improved clinical response in EGFR gene-mutated lung cancers. Purpose: To evaluate the use of computed tomography (CT)-guided core-needle biopsy specimens for the assessment of EGFR gene mutation in non-small-cell lung cancer (NSCLC). Material and Methods: Seventeen (nine males, eight females) patients with advanced NSCLC were enrolled in this study. All patients underwent CT-guided core-needle biopsy of the lung tumor prior to treatment with the EGFR inhibitor gefitinib. There were no life-threatening complications of biopsy. The specimens were sent fresh-frozen for EGFR mutation analysis and histopathological study. Results: There were 12 (70.6%) EGFR gene mutants and five (29.4%) nonmutants. The objective response rate to gefitinib therapy was 73.3% (11 of 15 patients), with 91.7% (11 of 12 mutants) for the mutant group and 0% for the nonmutant group. Conclusion: CT-guided core-needle biopsy of advanced NSCLC enables the acquisition of sufficient tissue for EGFR gene mutation analysis

  7. Diagnostic efficacy of ultrasound-guided core-needle biopsy of peripheral lymph nodes in sarcoidosis.

    Science.gov (United States)

    Boussouar, S; Medjhoul, A; Bernaudin, J F; Tayebjee, O; Soussan, M; Uzunhan, Y; Nunes, H; Kambouchner, M; Martin, A; Valeyre, D; Brillet, P Y

    2015-09-14

    Core-needle biopsy guided by ultrasound can be performed for investigating peripheral lymph node (PLN). The aim of this study was to determine the efficacy of this technique in sarcoidosis. Retrospective review of files of all patients in the database of the radiology department of Avicenne university hospital who underwent PLN biopsies guided by ultrasound from January 2008 to June 2011 (n=292). Cases with either granulomas at histology with the procedure or with a final diagnosis of sarcoidosis were included in the study. The histological specimens were adequate in 282 out of 292 cases (96%) showing non-caseating granulomas in 22 cases (n=20 patients with a final diagnosis of sarcoidosis and n=2 patients with tuberculosis). After reviewing clinical files of the 282 patient, 22 were confirmed to have sarcoidosis, at initial presentation (n=19) or later during flare-up or relapse (n=3) with only 2 patients having no granuloma on PLN biopsy. PLN were palpable in 18 cases and only detected by (18F)FDG-PET/CT showing increased PLN uptake in 4 cases. The sensitivity and specificity of adequate biopsy were 91 and 99% and the positive and negative predictive values were 91 and 99%, respectively. Core-needle biopsy guided by ultrasound has a high efficacy for evidencing granulomas in sarcoidosis patients with PLN involvement either clinically palpable or in the presence of (18F)FDG-PET/CT uptake.

  8. Uncommon primary tumors of the orbit diagnosed by computed tomography-guided core needle biopsy: report of two cases

    Energy Technology Data Exchange (ETDEWEB)

    Tyng, Chiang Jeng; Matushita Junior, Joao Paulo Kawaoka; Bitencourt, Almir Galvao Vieira; Amoedo, Mauricio Kauark; Barbosa, Paula Nicole Vieira; Chojniak, Rubens, E-mail: almirgvb@yahoo.com.br [A.C.Camargo Cancer Center, Sao Paulo, SP (Brazil). Dept. de Imagem; Neves, Flavia Branco Cerqueira Serra [Hospital do Servidor Publico Estadual, Sao Paulo, SP (Brazil). Div. de Oftalmologia

    2014-11-15

    Computed tomography-guided percutaneous biopsy is a safe and effective alternative method for evaluating selected intra-orbital lesions where the preoperative diagnosis is important for the therapeutic planning. The authors describe two cases of patients with uncommon primary orbital tumors whose diagnosis was obtained by means of computed tomography-guided core needle biopsy, with emphasis on the technical aspects of the procedure. (author)

  9. Percutaneous image-guided needle biopsy in children - summary of our experience with 57 children

    International Nuclear Information System (INIS)

    Sklair-Levy, M.; Lebensart, P.D.; Applbaum, Y.H.; Bar-Ziv, J.; Libson, E.; Ramu, N.; Freeman, A.; Gozal, D.; Gross, E.; Sherman, Y.

    2001-01-01

    Background: Percutaneous image-guided needle biopsy in children has been slower to gain acceptance than in adults where it is regarded as the standard clinical practice in screening suspicious masses. Objectives: To report our experience with percutaneous image-guided needle biopsy in the pediatric population and assess its clinical use, efficacy and limitations. Material and methods: Sixty-nine percutaneous image-guided needle biopsies were performed in 57 children. The age of the children ranged from 4 days to 14 years (mean 5.6 years). We used 16- to-20-gauge cutting-edge needles. Sixty-two biopsies were core-needle biopsies and 7 fine-needle aspiration biopsies. Results: There were 50 malignant lesions, 10 benign lesions and 2 infectious lesions. In 55 (88.7 %) lesions the needle biopsy was diagnostic. In 7 (11.3 %) the biopsy was non-diagnostic and the diagnosis was made by surgery. Core-needle biopsy was diagnostic in 47 of 50 (94 %) of the malignant solid tumors. In 3 out of 5 children with lymphoma, an accurate diagnosis was obtained with needle aspiration. Seven children underwent a repeated core-needle biopsy, (5 for Wilms' tumor and 2 for neuroblastoma) that was diagnostic in all cases. All the biopsies were performed without complications. Conclusion: Percutaneous image-guided needle biopsy is a simple, minimally invasive, safe and accurate method for the evaluation of children with suspicious masses. These data suggest that image-guided needle biopsy is an excellent tool for diagnosing solid tumors in the pediatric population. Negative studies should be considered nondiagnostic and followed by excisional surgical biopsies when clinical suspicion of malignancy is high. (orig.)

  10. Ultrasound-Guided Core-Needle Versus Vacuum-Assisted Breast Biopsy: A Cost Analysis Based on the American Society of Breast Surgeons' Mastery of Breast Surgery Registry.

    Science.gov (United States)

    Grady, Ian; Vasquez, Tony; Tawfik, Sara; Grady, Sean

    2017-03-01

    To evaluate the cost-efficacy of vacuum-assisted ultrasound-guided breast biopsy instruments compared to ultrasound-guided 14-gauge spring-loaded core-needle biopsy. The American Society of Breast Surgeons' Mastery of Breast Surgery Registry was reviewed. Biopsy findings, any rebiopsy, and the instrument used were abstracted for 31,451 ultrasound-guided biopsy procedures performed between 2001 and July 2014. Rates of cancer diagnosis and rebiopsy were calculated for each instrument. A linear mathematical model was developed to calculate total cost per cancer diagnosis, including procedural costs and the costs of any additional surgical rebiopsy procedures. Mean cost per cancer diagnosis with confidence limits was then determined for 14-gauge spring-loaded core-needle biopsy and 14 different vacuum-assisted instruments. For 14-gauge spring-loaded core-needle biopsy, mean cost per cancer diagnosis was $4346 (4327-$4366). For the vacuum-assisted instruments, mean cost per cancer diagnosis ranged from a low of $3742 ($3732-$3752) to a high of $4779 ($4750-$4809). Vacuum-assisted instruments overall were more cost-effective than core with a mean cost per cancer diagnosis of $4052 ($4038-$4067) (p cancer diagnosis of $3978 ($3964-$3991) (p cancer diagnosis of $4369 ($4350-$4388), a result no better than core (p breast biopsy had a lower mean cost per cancer diagnosis than 14-gauge spring-loaded core-needle biopsy. This advantage was only seen in tethered vacuum-assisted instruments. Within device families, larger instruments tended to outperform smaller instruments.

  11. CT-guided core needle biopsy of mediastinal nodes through a transpulmonary approach: retrospective analysis of the procedures conducted over six years

    Energy Technology Data Exchange (ETDEWEB)

    Yin, Zhongyuan; Liang, Zhiwen; Li, Pengcheng; Wang, Qiong [Huazhong University of Science and Technology, Cancer Center, Union Hospital, Tongji Medical College, Wuhan (China)

    2017-08-15

    To retrospectively evaluate the diagnostic performance and complications of a CT-guided core needle cutting biopsy of mediastinal nodes through a transpulmonary approach. From January 2009 to December 2014, we used a coaxial positioning system and an 18G cutting-type biopsy device to perform CT-guided percutaneous transpulmonary needle biopsies of mediastinal nodes for 127 patients. The diagnostic performance, complication rate, influencing factors, distribution of mediastinal nodes and pathological diagnoses were investigated. Among 127 patients, pathologic analyses showed that all of the biopsies were technically successful. The sensitivity, specificity, positive predictive value, and negative predictive value were all 100%. As for complications, the ratios for pneumothorax and hemoptysis were 33.9% and 4.7%, respectively. Multivariate analyses revealed that the distance from the pleura to the target lesion (P = 0.008) and the numbers of visceral pleura injuries (P = 0.006) were the two most significant risk factors for pneumothorax, and that the distance from the pleura to the target lesion (P = 0.004) was the most significant risk factor for hemoptysis. CT-guided core needle cutting biopsy of mediastinal nodes through a transpulmonary approach is a safe and efficient diagnostic method. (orig.)

  12. Guide for the realization of core needle biopsy through stereotaxy in the diagnosis of suspicious breast lesions of malignity

    International Nuclear Information System (INIS)

    Jimenez Zuniga, Jorge Luis

    2012-01-01

    demonstrated to be more precise and to make more accurate the diagnostic evaluation. While, the systems of vacuum-assisted biopsy have allowed the obtention of higher quality cylinders, clearly improving results, especially in cases of microcalcifications. The main indications for the use of stereotaxy in the intervention of the breast are analyzed, among which can be mentioned: fine-needle aspiration biopsy, core needle biopsy and preoperative localization. The technique of fine-needle aspiration biopsy has gained acceptation in the diagnosis of palpable lesions of the breast, the function of this technique in the management of nonpalpable lesions not is completely defined, due to the high percentage of insufficient samples. The systems of core needle biopsy have allowed the obtention of multiple cylinders with great diagnostic reliability, especially in the case of breast nodules. However, its use in microcalcifications has showed false negative results. The preoperative localization through needle in the nonpalpable lesions of the breast, has allowed to the radiologist to provide a guide to the surgeon that has realized the open biopsy, ensuring thus, that surgical procedure can be carried out quickly and with the best possible cosmetic result. The radiological assessment of the breast lesions in mammography are defined, in order to standardize the terminology applied at the time to report studies of the breast, to categorize the lesions according to the level of suspicion and to assign a recommendation to follow in injury determined. Before all nonpalpable breast lesion that has required a biopsy, should be considered first which will be the guidance system most adequate, and second, which is the technique with best diagnostic performing and better relationship cost/effectiveness. The core needle biopsy (CNB) has been a little aggressive technique and highly reliable in the diagnosis of the palpable and nonpalpable lesions. The sensitivity of the CNB has been different

  13. Factors influencing diagnostic yield of CT-guided percutaneous core needle biopsy for bone lesions

    International Nuclear Information System (INIS)

    Li, Y.; Du, Y.; Luo, T.Y.; Yang, H.F.; Yu, J.H.; Xu, X.X.; Zheng, H.J.; Li, B.

    2014-01-01

    Aim: To evaluate the factors influencing diagnostic yield of computed tomography (CT)-guided percutaneous core needle biopsy (CNB) for bone lesions. Materials and methods: Between September 2005 and July 2011, 162 consecutive CT-guided CNB procedures were performed in 155 patients. The variables analysed were age, sex, lesion location, lesion type, lesion size, specimen size, biopsy needle gauge, and individual radiologist. The factors influencing diagnostic yield of CT-guided percutaneous CNB for bone lesions were determined by multivariate analysis of variables. Results: The diagnostic yield was 81.5%. Diagnostic yield was 89.9% for lytic bone lesions and 48.5% for sclerotic bone lesions (p < 0.001), and 89.2% for lesions ≥3 cm and 73.4% for lesions <3 cm (p = 0.010). The significant factors influencing diagnostic yield of CT-guided percutaneous CNB for bone lesions were lesion type [p < 0.001; odds ratio (OR) for a lytic lesion was approximately 12 times higher than that for a sclerotic lesion; 95% confidence interval (CI): 4.22–34.01], and lesion size (p = 0.012; OR for a lesion size ≥3 cm was about five-times higher than that for a lesion size <3 cm; 95% CI: 1.42–16.71). Conclusion: Lesion type and lesion size are determining factors in diagnostic yield. The higher diagnostic yield is correlated with lytic lesion and lesion size ≥3 cm

  14. Percutaneous CT-Guided Core Needle Biopsy Versus Fine Needle Aspiration in Diagnosing Pneumonia and Mimics of Pneumonia

    International Nuclear Information System (INIS)

    Thanos, Loukas; Galani, Panagiota; Mylona, Sophia; Pomoni, Maria; Mpatakis, Nikolaos

    2004-01-01

    The purpose of this study was to determine the diagnostic value of percutaneous core needle biopsy (CNB) relative to fine needle aspiration (FNA) in patients with pneumonia and pneumonia mimics. In this prospective study we present our experience with 48 thoracic FNAs and CNBs carried out on 48 patients with pneumonia and pneumonia mimics. Samples were obtained from all patients using both CNB (with an automated 18-G core biopsy needle and a gun) and FNA (with a 22-G needle). A specific diagnosis was made in 10/48 cases (20.83%) by FNA and in 42/48 (87.5%) by CNB. The main complications encountered were pneumothorax (n = 4) and hemoptysis (n = 2), yielding a total complication rate of 12.5%. We concluded that CNB using an automated biopsy gun results in a higher diagnostic accuracy for pneumonia and pneumonia mimic biopsies than FNA. Complications should be considered and proper patient observation should follow the procedure

  15. The accuracy of frozen section analysis in ultrasound- guided core needle biopsy of breast lesions

    International Nuclear Information System (INIS)

    Brunner, Andreas H; Sagmeister, Thomas; Kremer, Jolanta; Riss, Paul; Brustmann, Hermann

    2009-01-01

    Limited data are available to evaluate the accuracy of frozen section analysis and ultrasound- guided core needle biopsy of the breast. In a retrospective analysis data of 120 consecutive handheldultrasound- guided 14- gauge automated core needle biopsies (CNB) in 109 consecutive patients with breast lesions between 2006 and 2007 were evaluated. In our outpatient clinic120 CNB were performed. In 59/120 (49.2%) cases we compared histological diagnosis on frozen sections with those on paraffin sections of CNB and finally with the result of open biopsy. Of the cases 42/59 (71.2%) were proved to be malignant and 17/59 (28.8%) to be benign in the definitive histology. 2/59 (3.3%) biopsies had a false negative frozen section result. No false positive results of the intraoperative frozen section analysis were obtained, resulting in a sensitivity, specificity and positive predicting value (PPV) and negative predicting value (NPV) of 95%, 100%, 100% and 90%, respectively. Histological and morphobiological parameters did not show up relevance for correct frozen section analysis. In cases of malignancy time between diagnosis and definitive treatment could not be reduced due to frozen section analysis. The frozen section analysis of suspect breast lesions performed by CNB displays good sensitivity/specificity characteristics. Immediate investigations of CNB is an accurate diagnostic tool and an important step in reducing psychological strain by minimizing the period of uncertainty in patients with breast tumor

  16. Ultrasound guided fine needle aspiration cytology versus core biopsy in the preoperative assessment of non-palpable breast lesions

    International Nuclear Information System (INIS)

    Ahmed, M.E.; Ahmad, I.

    2010-01-01

    Background: Breast screening is a method of detecting breast cancer at a very early stage. Most of the lesions detected by screening are not malignant. Objective of this study was to compare ultrasound guided fine needle aspiration cytology and core biopsy in the preoperative assessment of non-palpable breast lesions. Methods: The study was conducted prospectively at Department of Radiology, Shaukat Khanum Memorial Cancer Hospital and Research Centre, Pakistan from March 2004 to February 2005. All the patients underwent fine needle aspiration cytology and core biopsy. Later on, all of them had excision biopsy/ mastectomy. Prospectively 80 patients were studied; information was collected on a specifically designed form according to inclusion criteria. The patient age, sex, medical record number and side of lesion were recorded. Clinical history of duration of lump was also taken. Informed consent was obtained. Results: The age of patients were ranges from 20-71 years, with mean of 44.31+- 11.002 and the maximum number of patients 28 (35.3%) was between the ages 50 - 59 years. The sensitivity of FNAC was 92.85%, while the specificity of was 90% and the accuracy rate was 92.1%. The sensitivity of core biopsy was 94.64%, specificity 91.30% and accuracy rate was 94.87%. Conclusion: Fine Needle Aspiration has been found to be an extremely useful method for the diagnosis of lumps of breast. The accuracy and the sensitivity of diagnosis on fine needle aspiration cytology were high. (author)

  17. Hematoma formation during breast core needle biopsy in women taking antithrombotic therapy.

    Science.gov (United States)

    Chetlen, Alison L; Kasales, Claudia; Mack, Julie; Schetter, Susann; Zhu, Junjia

    2013-07-01

    The purpose of this study was to compare hematoma formation after breast core needle biopsy performed on patients undergoing and those not undergoing concurrent antithrombotic therapy. A prospective assessment of core needle biopsies (stereotactic, ultrasound guided, or MRI guided) performed on patients enrolled between September 2011 and July 2012 formed the basis of this study. Postprocedure mediolateral and craniocaudal mammograms were evaluated for the presence and size of hematomas. Patients were clinically evaluated for complications 24-48 hours after the procedure through telephone call or face-to-face consultation. Needle size, type of biopsy, and presence of hematoma and documented complications were correlated with use of antithrombotic agents (including aspirin, warfarin, clopidogrel, and daily nonsteroidal antiinflammatory medications). No clinically significant hematomas or bleeding complications were found. Eighty-nine of 617 (14.4%) non-clinically significant hematomas were detected on postprocedure mammograms. The probability of development of a non-clinically significant hematoma was 21.6% for patients taking antithrombotics and 13.0% for those not taking antithrombotics. Concurrent antithrombotic therapy and larger needle gauge were significant factors contributing to the probability of hematoma formation. The volume of the hematoma was not related to needle gauge or presence of antithrombotic therapy. No clinically significant hematomas were found. Because there are potential life-threatening risks to stopping antithrombotic therapy before breast biopsy, withholding antithrombotic therapy for core needle breast biopsy is not recommended because the incidence of non-clinically significant hematoma is low.

  18. Image-guided core-needle biopsy of peripheral lymph nodes allows the diagnosis of lymphomas

    International Nuclear Information System (INIS)

    Kerviler, Eric de; Bazelaire, Cedric de; Mathieu, Olivier; Frija, Jacques; Mounier, Nicolas; Gisselbrecht, Christian; Brethon, Benoit; Briere, Josette; Marolleau, Jean-Pierre; Brice, Pauline

    2007-01-01

    It is commonly admitted that the diagnosis of lymphomas can be assessed by the image-guided needle biopsy (IGNB) of deep lymph nodes. However, when peripheral lymph nodes are present, surgical dissection remains the standard strategy. The aim of this study was to evaluate the diagnostic yield of IGNB of peripheral lymph nodes in patients with suspected lymphomas. The records of 180 multisampling IGNBs of peripheral lymph nodes in 180 patients were reviewed. One hundred and twenty-three IGNBs were observed at first diagnosis and 57 at progression using large-cutting core-biopsy needles ranging between 18 G and 14 G in size. Immunohistochemistry studies were performed in all cases and at least one biopsy was systematically frozen. A diagnosis of lymphoma with sufficient information such that a therapeutic decision could be made was obtained in 146 of the 152 patients with lymphoproliferative disorders (96%). IGNB was equally effective in making the correct diagnosis of lymphoma at the time of original diagnosis than at relapse. The results did not depend on the biopsy site, lymph nodes size, or needle type. We recommend that IGNB may be performed as an initial procedure for the diagnosis of lymphomas either in the presence of peripheral or deep lymph nodes, as it avoids surgery. (orig.)

  19. Practical guidelines for ultrasound-guided core needle biopsy of soft-tissue lesions: Transformation from beginner to specialist

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Yoon; Chung, Hye Won; Oh, Tack Sun; Lee, Jong Seok [University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2017-04-15

    Ultrasound-guided core needle biopsy (US-CNB) is an important step in the diagnosis of musculoskeletal soft-tissue lesions. To maximize efficacy and minimize the complications of US-CNB, it is critical to collaborate with a multidisciplinary team and to understand the particular considerations of US-CNB for these lesions. The purpose of this article is to provide a systematic review and step-by-step tips for using US-CNB to diagnose musculoskeletal soft-tissue lesions.

  20. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking.......To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  1. Transjugular liver biopsy : the efficacy of quick-core biopsy needle system

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Gyoo Sik; Ahn, Byung Kwon; Lee, Sang Ouk; Chang, Hee Kyong; Oh, Kyung Seung; Huh, Jin Do; Joh, Young Duk [Kosin Medical College, Pusan (Korea, Republic of)

    1998-02-01

    To evaluate the efficacy of the Quick-Core biopsy needle system in performing transjugular liver biopsy. Between December 1995 and June 1997, eight patients underwent transjugular liver biopsy involving use of the Quick-Core biopsy needle system; the conditions involved were coagulopathy (n=4), thrombocytopenia (n=3), and ascites (n=1). Via the right internal jugular vein, the right hepatic vein was selectively catheterized with a 7-F transjugular guiding catheter, and a14-guage stiffening cannula was then inserted through this catheter; to obtain core tissue, a Quick-Core needle was then advanced into the liver parenchyma through the catheter-cannula combination. Eighteen- and 19-guage needles were used in three and five patients, respectively; specimen size, adequacy of the biopsy specimen and histologic diagnosis were determined, and complications were recorded. Biopsy was successful in all patients. The mean length of the specimen was 1.4 cm (1.0 - 1.8 cm), and all were adequate for pathologic examinations ; specific diagnosis was determined in all patients. There were two malignant neoplasms, two cases of veno-occlusive disease, and one case each of cirrhosis, fulminant hepatitis, Banti syndrome and Budd-Chiari syndrome. One patient complained of neck pain after the procedure, but no serious procedural complications were noted. Our preliminary study shows that the Quick-Core biopsy needle system is safe and provides adequate core tissues with high diagnostic yields. (author). 23 refs., 1 tab., 3 figs.

  2. Transjugular liver biopsy : the efficacy of quick-core biopsy needle system

    International Nuclear Information System (INIS)

    Jung, Gyoo Sik; Ahn, Byung Kwon; Lee, Sang Ouk; Chang, Hee Kyong; Oh, Kyung Seung; Huh, Jin Do; Joh, Young Duk

    1998-01-01

    To evaluate the efficacy of the Quick-Core biopsy needle system in performing transjugular liver biopsy. Between December 1995 and June 1997, eight patients underwent transjugular liver biopsy involving use of the Quick-Core biopsy needle system; the conditions involved were coagulopathy (n=4), thrombocytopenia (n=3), and ascites (n=1). Via the right internal jugular vein, the right hepatic vein was selectively catheterized with a 7-F transjugular guiding catheter, and a14-guage stiffening cannula was then inserted through this catheter; to obtain core tissue, a Quick-Core needle was then advanced into the liver parenchyma through the catheter-cannula combination. Eighteen- and 19-guage needles were used in three and five patients, respectively; specimen size, adequacy of the biopsy specimen and histologic diagnosis were determined, and complications were recorded. Biopsy was successful in all patients. The mean length of the specimen was 1.4 cm (1.0 - 1.8 cm), and all were adequate for pathologic examinations ; specific diagnosis was determined in all patients. There were two malignant neoplasms, two cases of veno-occlusive disease, and one case each of cirrhosis, fulminant hepatitis, Banti syndrome and Budd-Chiari syndrome. One patient complained of neck pain after the procedure, but no serious procedural complications were noted. Our preliminary study shows that the Quick-Core biopsy needle system is safe and provides adequate core tissues with high diagnostic yields. (author). 23 refs., 1 tab., 3 figs

  3. Ultrasound-guided percutaneous core needle biopsy of abdominal viscera: Tips to ensure safe and effective biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Woong; Shin, Sang Soo [Chonnam National University Hospital, Chonnam National University Medical School, Gwangju(Korea, Republic of)

    2017-04-15

    Ultrasound-guided percutaneous core needle biopsy (USPCB) is used extensively in daily clinical practice for the pathologic confirmation of both focal and diffuse diseases of the abdominal viscera. As a guidance tool, US has a number of clear advantages over computerized tomography or magnetic resonance imaging: fewer false-negative biopsies, lack of ionizing radiation, portability, relatively short procedure time, real-time intra-procedural visualization of the biopsy needle, ability to guide the procedure in almost any anatomic plane, and relatively lower cost. Notably, USPCB is widely used to retrieve tissue specimens in cases of hepatic lesions. However, general radiologists, particularly beginners, find USPCB difficult to perform in abdominal organs other than the liver; indeed, a full understanding of the entire USPCB process and specific considerations for specific abdominal organs is necessary to safely obtain adequate specimens. In this review, we discuss some points and techniques that need to be borne in mind to increase the chances of successful USPCB. We believe that the tips and considerations presented in this review will help radiologists perform USPCB to successfully retrieve target tissue from different organs with minimal complications.

  4. Ultrasound-guided percutaneous core needle biopsy of abdominal viscera: Tips to ensure safe and effective biopsy

    International Nuclear Information System (INIS)

    Kim, Jin Woong; Shin, Sang Soo

    2017-01-01

    Ultrasound-guided percutaneous core needle biopsy (USPCB) is used extensively in daily clinical practice for the pathologic confirmation of both focal and diffuse diseases of the abdominal viscera. As a guidance tool, US has a number of clear advantages over computerized tomography or magnetic resonance imaging: fewer false-negative biopsies, lack of ionizing radiation, portability, relatively short procedure time, real-time intra-procedural visualization of the biopsy needle, ability to guide the procedure in almost any anatomic plane, and relatively lower cost. Notably, USPCB is widely used to retrieve tissue specimens in cases of hepatic lesions. However, general radiologists, particularly beginners, find USPCB difficult to perform in abdominal organs other than the liver; indeed, a full understanding of the entire USPCB process and specific considerations for specific abdominal organs is necessary to safely obtain adequate specimens. In this review, we discuss some points and techniques that need to be borne in mind to increase the chances of successful USPCB. We believe that the tips and considerations presented in this review will help radiologists perform USPCB to successfully retrieve target tissue from different organs with minimal complications

  5. CT-guided biopsy with cutting-edge needle for the diagnosis of malignant lymphoma: Experience of 267 biopsies

    International Nuclear Information System (INIS)

    Agid, R.; Sklair-Levy, M.; Bloom, A.I.; Lieberman, S.; Polliack, A.; Ben-Yehuda, D.; Sherman, Y.; Libson, E.

    2003-01-01

    AIM: We performed a retrospective study of 267 core needle aspiration biopsies in order to estimate the accuracy of CT-guided aspiration core needle biopsies for the diagnosis and subsequent treatment of malignant lymphoma. MATERIALS AND METHODS: Between 1989 and 1999, 267 CT-guided core needle biopsies were performed in 241 patients with either primary or recurrent malignant lymphoma. Patients age ranged from 4--88 years. One hundred and sixty-six (62.2%) nodal and 101 (37.8%) extranodal aspiration biopsies were performed using either 18 G or 20 G Turner needles. Statistical method used was Chi-square analysis. RESULTS: An accurate histological diagnosis was made in 199 (82.5%) patients, the remaining 42 (17.4%) patients had non-diagnostic CT biopsies. Thirty-seven of them were diagnosed by a surgical biopsy, four by bone marrow biopsy and in one patient by paracentesis. One hundred and seventy-nine patients had non-Hodgkin's lymphoma (NHL) and 62 had Hodgkin's disease (HD); 23 (9.54%) patients underwent repeated CT biopsy which was diagnostic in 17 (73.9%) and non-diagnostic in six (26%). CONCLUSION: CT-guided aspiration core biopsies were sufficient to establish a diagnosis in lymphoproliferative disorders in 82.5% of cases. In the light of this experience we suggest that imaging-guided core needle biopsy be used as the first step in the work up of many patients with lymphoma Agid,R. et al. (2003). Clinical Radiology58, 143-147

  6. Design and Production of an Articulating Needle Guide for Ultrasound-Guided Needle Block Manufactured With a Three-Dimensional Printer: Technical Communication.

    Science.gov (United States)

    Bigeleisen, Paul E

    2017-05-15

    Needle guides may allow the practitioner to align the needle with the probe when ultrasound-guided nerve block is performed. The author's goal was to design and fabricate an inexpensive ($1.90), disposable, needle guide that could articulate over a range from 85 degrees to 0 degrees with a three-dimension printer. Three-dimensional representations of an L50, L25, and C 60 ultrasound probe (Sono Site, Bothell, WA) were created using a laser scanner. Computer-aided design software (Solid Works, Waltham, MA) was used to design a needle bracket and needle guide to attach to these probes. A three-dimensional printer was used to fabricate the needle bracket and guide with acrylonitrile polybutadiene polystyrene. An echogenic needle was held in plane with the needle guide. The author performed a supraclavicular block in a morbidly obese patient. The needle was easily visualized. Similar guides that are commercially available cost as much as $400. A knowledge of computer-aided design is necessary for this work.

  7. Prospective evaluation of EUS-guided fine needle biopsy in pancreatic mass lesions

    DEFF Research Database (Denmark)

    Larsen, M H; Fristrup, C W; Detlefsen, S

    2018-01-01

    Background and study aim : Due to the scarcity of specific data on endoscopic ultrasound (EUS)-guided fine-needle biopsies (SharkCore) FNB in the evaluation of pancreatic lesions, we performed a prospective study of the diagnostic performance of EUS SharkCore FNB in patients with pancreatic lesions...

  8. Usefulness of the coaxial technique in US-guided breast core biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Hyun; Lee, Jeong Hwa; Ha, Jeon Ju; Lee, Keon; Kim, Won Ho; Kwon, Jung Hyeok [Dongkang general hospital, Seoul (Korea, Republic of); Ham, Soo Youn [Ulsan Univ. Hospital, Ulsan (Korea, Republic of)

    1999-05-01

    To evaluate the usefulness of the coaxial technique in US-guided breast core biopsy. Using the coaxial technique, US-guided breast core biopsy was performed in 49 breast lesions (40 patients). Under US-guidance the 17-gauge, 13 cm long introducer needle was positioned proximal to the lesion. Once the needle was in place, the central trocar was removed and was replaced with the core biopsy needle. We used an 18-gauge, 16-cm-long core biopsy needle with a 17 mm specimen notch. Four to eight tissue specimens were obtained from each lesion, and the quality and quantity of specimens, procedure time, and complications and their rate were evaluated. For 48 of 49 lesions, specimens were adequate for histopathologic diagnosis, and the findings were as follows : six cases of invasive ductal carcinoma, one of ductal carcinoma in situ, 29 of fibrocystic disease, eight of fibroadenoma, two of chronic inflammation, and two of sclerosing lesion. In 12 lesions agreement between the pathologic results of needle core biopsy and surgical results was 100%. The procedure time was about 15 minutes and no significant complications were noted. In breast core biopsy, the coaxial technique is simple and time-saving, and compared with standard breast core biopsy, may also be less traumatic and decrease the potential risk of seeding the biopsy tract with malignant cells.

  9. Usefulness of the coaxial technique in US-guided breast core biopsy

    International Nuclear Information System (INIS)

    Kim, Dong Hyun; Lee, Jeong Hwa; Ha, Jeon Ju; Lee, Keon; Kim, Won Ho; Kwon, Jung Hyeok; Ham, Soo Youn

    1999-01-01

    To evaluate the usefulness of the coaxial technique in US-guided breast core biopsy. Using the coaxial technique, US-guided breast core biopsy was performed in 49 breast lesions (40 patients). Under US-guidance the 17-gauge, 13 cm long introducer needle was positioned proximal to the lesion. Once the needle was in place, the central trocar was removed and was replaced with the core biopsy needle. We used an 18-gauge, 16-cm-long core biopsy needle with a 17 mm specimen notch. Four to eight tissue specimens were obtained from each lesion, and the quality and quantity of specimens, procedure time, and complications and their rate were evaluated. For 48 of 49 lesions, specimens were adequate for histopathologic diagnosis, and the findings were as follows : six cases of invasive ductal carcinoma, one of ductal carcinoma in situ, 29 of fibrocystic disease, eight of fibroadenoma, two of chronic inflammation, and two of sclerosing lesion. In 12 lesions agreement between the pathologic results of needle core biopsy and surgical results was 100%. The procedure time was about 15 minutes and no significant complications were noted. In breast core biopsy, the coaxial technique is simple and time-saving, and compared with standard breast core biopsy, may also be less traumatic and decrease the potential risk of seeding the biopsy tract with malignant cells

  10. CT fluoroscopy-guided core needle biopsy of anterior mediastinal masses.

    Science.gov (United States)

    Iguchi, T; Hiraki, T; Matsui, Y; Fujiwara, H; Sakurai, J; Masaoka, Y; Uka, M; Tanaka, T; Gobara, H; Kanazawa, S

    2018-02-01

    To retrospectively evaluate the safety, diagnostic yield, and risk factors of diagnostic failure of computed tomography (CT) fluoroscopy-guided biopsies of anterior mediastinal masses. Biopsy procedures and results of anterior mediastinal masses in 71 patients (32 women/39 men; mean [±standard deviation] age, 53.8±20.0years; range, 14-88years) were analyzed. Final diagnoses were based on surgical outcomes, imaging findings, or clinical follow-up findings. The biopsy results were compared with the final diagnosis, and the biopsy procedures grouped by pathologic findings into diagnostic success and failure groups. Multiple putative risk factors for diagnostic failure were then assessed. Seventy-one biopsies (71 masses; mean size, 67.5±27.3mm; range 8.6-128.2mm) were analyzed. We identified 17 grade 1 and one grade 2 adverse events (25.4% overall) according to the National Cancer Institute Common Terminology Criteria for Adverse Events version 4.0. Sixty-nine biopsies (97.2%) provided samples fit for pathologic analysis. Diagnostic failure was found for eight (11.3%) masses; the 63 masses diagnosed successfully included thymic carcinoma (n=17), lung cancer (n=14), thymoma (n=12), malignant lymphoma (n=11), germ cell tumor (n=3), and others (n=6). Using a thinner needle (i.e., a 20-gauge needle) was the sole significant risk factor for diagnostic failure (P=0.039). CT fluoroscopy-guided biopsy of anterior mediastinal masses was safe and had a high diagnostic yield; however, using a thinner biopsy needle significantly increased the risk of a failed diagnosis. Copyright © 2017 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  11. CT-guided percutaneous core needle biopsy in deep seated musculoskeletal lesions: a prospective study of 128 cases

    International Nuclear Information System (INIS)

    Puri, A.; Shingade, V.U.; Agarwal, M.G.; Anchan, C.; Juvekar, S.; Desai, S.; Jambhekar, N.A.

    2006-01-01

    Although large lesions of the limbs can easily be biopsied without image guidance, lesions in the spine, paraspinal area and pelvis are difficult to target, and benefit from CT guidance to improve the accuracy of targeting the lesion for biopsy purposes. A prospective study of CT-guided core needle biopsies for deep-seated musculoskeletal lesions was conducted at a referral cancer institute over a 4-year period with the aim of assessing the safety and efficacy of the procedure. From January 2000 to December 2003, 136 consecutive CT-guided biopsy sessions were undertaken for musculoskeletal lesions in 128 patients comprising 73 males and 55 females. The following data was recorded in all patients: demographic data, suspected clinicoradiological diagnosis, data related to core biopsy session (date, site, approach, total time required in minutes, number of cores, surgeon satisfaction with adequacy of cores), patient discomfort, complications, histopathology report and number of further sessions if material obtained during the first biopsy session was not confirmatory. The sample obtained during the biopsy session was considered inconclusive if, in the opinion of the pathologist, inadequate or non-representative tissue had been obtained. The diagnosis was considered inaccurate if the final histopathological diagnosis did not match with the biopsy diagnosis, or if subsequent clinicoradiological evaluation at follow up did not correlate with the biopsy diagnosis in those patients who were treated with modalities other than surgery. In 121 patients, a single session was sufficient to obtain representative material, whilst for six patients two sessions, and for one patient three sessions were necessary. The time taken for biopsy, including the pre-biopsy CT examination time, varied from 15 min to 60 min (median 30 min). For 110 bony lesions 116 sessions were required, and for 18 soft-tissue lesions 20 sessions were required. 108 biopsy sessions yielded a diagnosis, whilst

  12. CT-guided transthoracic core needle biopsy for small pulmonary lesions: diagnostic performance and adequacy for molecular testing.

    Science.gov (United States)

    Tian, Panwen; Wang, Ye; Li, Lei; Zhou, Yongzhao; Luo, Wenxin; Li, Weimin

    2017-02-01

    Computed tomography (CT)-guided transthoracic needle biopsy is a well-established, minimally invasive diagnostic tool for pulmonary lesions. Few large studies have been conducted on the diagnostic performance and adequacy for molecular testing of transthoracic core needle biopsy (TCNB) for small pulmonary lesions. This study included CT-guided TCNB with 18-gauge cutting needles in 560 consecutive patients with small (≤3 cm) pulmonary lesions from January 2012 to January 2015. There were 323 males and 237 females, aged 51.8±12.7 years. The size of the pulmonary lesions was 1.8±0.6 cm. The sensitivity, specificity, accuracy and complications of the biopsies were investigated. The risk factors of diagnostic failure were assessed using univariate and multivariate analyses. The sample's adequacy for molecular testing of non-small cell lung cancer (NSCLC) was analyzed. The overall sensitivity, specificity, and accuracy for diagnosis of malignancy were 92.0% (311/338), 98.6% (219/222), and 94.6% (530/560), respectively. The incidence of bleeding complications was 22.9% (128/560), and the incidence of pneumothorax was 10.4% (58/560). Logistic multivariate regression analysis showed that the independent risk factors for diagnostic failure were a lesion size ≤1 cm [odds ratio (OR), 3.95; P=0.007], lower lobe lesions (OR, 2.83; P=0.001), and pneumothorax (OR, 1.98; P=0.004). Genetic analysis was successfully performed on 95.45% (168/176) of specimens diagnosed as NSCLC. At least 96.8% of samples with two or more passes from a lesion were sufficient for molecular testing. The diagnostic yield of small pulmonary lesions by CT-guided TCNB is high, and the procedure is relatively safe. A lesion size ≤1 cm, lower lobe lesions, and pneumothorax are independent risk factors for biopsy diagnostic failure. TCNB specimens could provide adequate tissues for molecular testing.

  13. Ultrasonography-guided core needle biopsy for the thyroid nodule: does the procedure hold any benefit for the diagnosis when fine-needle aspiration cytology analysis shows inconclusive results?

    Science.gov (United States)

    Hahn, S Y; Han, B-K; Ko, E Y; Ko, E S

    2013-01-01

    Objective: We evaluated the diagnostic role of ultrasonography-guided core needle biopsy (CNB) according to ultrasonography features of thyroid nodules that had inconclusive ultrasonography-guided fine-needle aspiration (FNA) results. Methods: A total of 88 thyroid nodules in 88 patients who underwent ultrasonography-guided CNB because of previous inconclusive FNA results were evaluated. The patients were classified into three groups based on ultrasonography findings: Group A, which was suspicious for papillary thyroid carcinoma (PTC); Group B, which was suspicious for follicular (Hurthle cell) neoplasm; and Group C, which was suspicious for lymphoma. The final diagnoses of the thyroid nodules were determined by surgical confirmation or follow-up after ultrasonography-guided CNB. Results: Of the 88 nodules, the malignant rate was 49.1% in Group A, 12.0% in Group B and 90.0% in Group C. The rates of conclusive ultrasonography-guided CNB results after previous incomplete ultrasonography-guided FNA results were 96.2% in Group A, 64.0% in Group B and 90.0% in Group C (p=0.001). 12 cases with inconclusive ultrasonography-guided CNB results were finally diagnosed as 8 benign lesions, 3 PTCs and 1 lymphoma. The number of previous ultrasonography-guided FNA biopsies was not significantly different between the conclusive and the inconclusive result groups of ultrasonography-guided CNB (p=0.205). Conclusion: Ultrasonography-guided CNB has benefit for the diagnosis of thyroid nodules with inconclusive ultrasonography-guided FNA results. However, it is still not helpful for the differential diagnosis in 36% of nodules that are suspicious for follicular neoplasm seen on ultrasonography. Advances in knowledge: This study shows the diagnostic contribution of ultrasonography-guided CNB as an alternative to repeat ultrasonography-guided FNA or surgery. PMID:23564885

  14. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  15. The reliability of ultrasound-guided core needle biopsy in the evaluation of non-palpable solid breast lesions using 18-gauge needles

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Sung Chul; Kim, Young Sook [Chosun University College of Medicine, Gwangju (Korea, Republic of); Sneige, Nour [The University of Texas M.D. Andreson Carcer Canter, Houston (United States)

    2003-04-01

    Ultrasound-guided core needle biopsy (US CNB) is increasingly used in the histologic evaluation of non-palpable solid breast lesions. We retrospectively investigated the diagnostic accuracy of this technique, using an 18-gauge needle in 422 non-palpable breast lesions. 583 female patients with an average age 56 (range, 22-90) years underwent 590 US CNBs. Between January 1994 and December 1999, using 18-gauge needles, an average of four cores per lesion was obtained. Three hundred and eighty-five lesions were subsequently surgically excised; for 14 of these, the pathologic diagnosis was breast carcinoma metastasis, while 23 with benign diagnoses were clinically followed up for {>=}2.5 years and were considered for analysis. Of the 422 lesions, 340 (80.6%) were malignant [308 invasive, 24 ductal carcinoma in situ (DCIS), 7 DCIS with undetermined invasion and 1 DCIS vs. lobular carcinoma in situ], 67 (15.9%) were benign [30 fibroadenoma (FA) and 37 other diagnoses], and five (1.2%) were fibroepithelial lesions. The remaining ten samples (2,4%) included six cases of atypical ductal hyperplasia (ADH), two of atypical hyperplasia (AH), and two of lobular neoplasia. The sensitivity, specificity, positive predictive value, and negative predictive value of CNBs were 99%, 100%, 100%, and 96%, respectively. Two cases of invasive carcinoma were missed at CNB; there was no false-positive diagnosis. Five of six ADHs and one of two AHs were found to be carcinomas (3 DCIS and 3 infiltrating duct carcinomas). Sixteen of 24 (66.7%) cases of DCIS were found at excision to be invasion carcinomas. Of 31 FAs, two (6.5%) were found to be low-grade phyllodes tumor (PT). The five fibroepithelial lesions were shown at excision to be either PT (n=4) or FA (n=1). US CNB using an 18-gauge needle is a safe and reliable means of diagnosing breast carcinoma. Because of the high prevalence of ductal carcinoma is these lesions; findings of ADH/AH at US CNB indicate that surgical excision is needed

  16. Accuracy and complications of CT-guided core needle biopsy of peripheral nerve sheath tumours

    Energy Technology Data Exchange (ETDEWEB)

    Pianta, Marcus; Chock, Eric; Schlicht, Stephen [St Vincent' s Hospital, Fitzroy, VIC (Australia); McCombe, David [St Vincent' s Hospital and Victorian Hand Surgery Associates, Victoria (Australia)

    2015-09-15

    This single-centre study retrospectively reviews the complications in patients that have occurred following peripheral nerve sheath tumour biopsy, and assesses whether there is an association with biopsy technique or underlying lesion characteristics. 41 consecutive core needle biopsies of proven peripheral nerve sheath tumours over a 2-year period in a tertiary teaching hospital were reviewed. Patient demographics and symptoms, tumour characteristics and radiological appearances were recorded. Biopsy and surgical histology were correlated, and post-biopsy and surgical complications analyzed. 41 biopsies were performed in 38 patients. 68 % schwannomas, 24 % neurofibromas and 7 % malignant peripheral nerve sheath tumours. Biopsy histology correlated with surgery in all cases. 71 % of lesions were surgically excised. 60 % of patients reported pain related to their lesion. Following the biopsy, 12 % reported increased pain, which resolved in all cases. Pain exacerbation was noted in tumours smaller in size, more superficial and in closer proximity of the biopsy needle tip to the traversing nerve. Number of biopsy needle passes was not associated with an increased incidence of procedure-related pain. Core biopsy of a suspected peripheral nerve sheath tumour may be performed safely before excisional surgery to confirm lesion histology and assist prognosis. There is excellent correlation between core biopsy and excised surgical specimen histology. The most common complication of pain exacerbation is seen in a minority and is temporary, and more likely with smaller, more superficial lesions and a closer needle-tip to traversing nerve distance during biopsy. (orig.)

  17. Accuracy and complications of CT-guided core needle biopsy of peripheral nerve sheath tumours

    International Nuclear Information System (INIS)

    Pianta, Marcus; Chock, Eric; Schlicht, Stephen; McCombe, David

    2015-01-01

    This single-centre study retrospectively reviews the complications in patients that have occurred following peripheral nerve sheath tumour biopsy, and assesses whether there is an association with biopsy technique or underlying lesion characteristics. 41 consecutive core needle biopsies of proven peripheral nerve sheath tumours over a 2-year period in a tertiary teaching hospital were reviewed. Patient demographics and symptoms, tumour characteristics and radiological appearances were recorded. Biopsy and surgical histology were correlated, and post-biopsy and surgical complications analyzed. 41 biopsies were performed in 38 patients. 68 % schwannomas, 24 % neurofibromas and 7 % malignant peripheral nerve sheath tumours. Biopsy histology correlated with surgery in all cases. 71 % of lesions were surgically excised. 60 % of patients reported pain related to their lesion. Following the biopsy, 12 % reported increased pain, which resolved in all cases. Pain exacerbation was noted in tumours smaller in size, more superficial and in closer proximity of the biopsy needle tip to the traversing nerve. Number of biopsy needle passes was not associated with an increased incidence of procedure-related pain. Core biopsy of a suspected peripheral nerve sheath tumour may be performed safely before excisional surgery to confirm lesion histology and assist prognosis. There is excellent correlation between core biopsy and excised surgical specimen histology. The most common complication of pain exacerbation is seen in a minority and is temporary, and more likely with smaller, more superficial lesions and a closer needle-tip to traversing nerve distance during biopsy. (orig.)

  18. Comparison of needles size in pediatric renal biopsy with sono-guided percutaneous-automated gun technique

    International Nuclear Information System (INIS)

    Kim, Jong Chul; Park, Jin Yong

    1997-01-01

    To compare the efficacy of a 20-gauge and an 18-gauge needle in sono-guided percutaneous automated gun biopsy for establishing the specific diagnosis of renal parenchymal disease in pediatric kidneys. In 60 pediatric patients with renal parenchymal diseases, percutaneous sono-guided gun biopsy was performed by an experienced radiologist. In two groups of 30 patients, regardless of their age, two needle passes were performed, using alternately an 18-gauge or a 20-gauge biopsy needle. The core of renal tissue thus obtained was examined with light, immunofluorescent or electron microscopy by the renal pathologist. The mean number of intact glomeruli of whole tissue core per biopsy, as seen on the light microscopy, and post-bioptic complications were compared between the two different needle size groups. The number (mean±1 standard deviation) of glomeruli obtained per biopsy was 17±8 in the 18-gauge needle group, and 14±5 in the 20-gauge group. Between two groups, there was no major post-bioptic complication requiring specific treatment, nor a statistically significant difference in the frequency of minor complications. Even though more glomeruli were obtained with an 18-gauge needle, the number obtained with a 20-gauge needle also permitted adequate pathologic examination. Both an 18-gauge and a 20-gauge needle may thus be suitable for renal biopsy in pediatric patients

  19. Current status of core needle biopsy of the thyroid

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Jung Hwan [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2017-04-15

    Thyroid nodules are a common clinical problem. Fine-needle aspiration (FNA) and large-needle biopsy have been used to diagnose thyroid nodules. Before the 1980s, large-needle biopsy was the standard procedure for the thyroid, but FNA became the standard diagnostic tool in the 1980s because it is a safe procedure that leads to accurate diagnoses. With advances in core needle biopsy (CNB) devices (i.e., spring-activated core needles) and development of high-resolution ultrasound, it has become possible to make accurate diagnoses while minimizing complications. Although 18- to 21-gauge core needles can be used to biopsy thyroid nodules, 18-gauge needles are most commonly used in Korea. The relationships among the size of the needle, the number of core specimens, and diagnostic accuracy have not yet been conclusively established, but the general tendency is that thinner needles cause less damage to the normal thyroid, but allow a smaller amount of thyroid tissue to be biopsied to be obtained. These relationships may be validated in the future.

  20. Ultrasound probe and needle-guide calibration for robotic ultrasound scanning and needle targeting.

    Science.gov (United States)

    Kim, Chunwoo; Chang, Doyoung; Petrisor, Doru; Chirikjian, Gregory; Han, Misop; Stoianovici, Dan

    2013-06-01

    Image-to-robot registration is a typical step for robotic image-guided interventions. If the imaging device uses a portable imaging probe that is held by a robot, this registration is constant and has been commonly named probe calibration. The same applies to probes tracked by a position measurement device. We report a calibration method for 2-D ultrasound probes using robotic manipulation and a planar calibration rig. Moreover, a needle guide that is attached to the probe is also calibrated for ultrasound-guided needle targeting. The method is applied to a transrectal ultrasound (TRUS) probe for robot-assisted prostate biopsy. Validation experiments include TRUS-guided needle targeting accuracy tests. This paper outlines the entire process from the calibration to image-guided targeting. Freehand TRUS-guided prostate biopsy is the primary method of diagnosing prostate cancer, with over 1.2 million procedures performed annually in the U.S. alone. However, freehand biopsy is a highly challenging procedure with subjective quality control. As such, biopsy devices are emerging to assist the physician. Here, we present a method that uses robotic TRUS manipulation. A 2-D TRUS probe is supported by a 4-degree-of-freedom robot. The robot performs ultrasound scanning, enabling 3-D reconstructions. Based on the images, the robot orients a needle guide on target for biopsy. The biopsy is acquired manually through the guide. In vitro tests showed that the 3-D images were geometrically accurate, and an image-based needle targeting accuracy was 1.55 mm. These validate the probe calibration presented and the overall robotic system for needle targeting. Targeting accuracy is sufficient for targeting small, clinically significant prostatic cancer lesions, but actual in vivo targeting will include additional error components that will have to be determined.

  1. CT-guided core needle biopsy of pleural lesions: Evaluating diagnostic yield and associated complications

    International Nuclear Information System (INIS)

    Niu, Xiang Ke; Bhetuwal, Anup; Yang, Han Feng

    2015-01-01

    The purpose of this study was to retrospectively evaluate the diagnostic accuracy and complications of CT-guided core needle biopsy (CT-guided CNB) of pleural lesion and the possible effects of influencing factors. From September 2007 to June 2013, 88 consecutive patients (60 men and 28 women; mean [+/- standard deviation] age, 51.1 +/- 14.4 years; range, 19-78 years) underwent CT-guided CNB, which was performed by two experienced chest radiologists in our medical center. Out of 88 cases, 56 (63%) were diagnosed as malignant, 28 (31%) as benign and 4 (5%) as indeterminate for CNB of pleural lesions. The final diagnosis was confirmed by either histopathological diagnosis or clinical follow-up. The diagnostic accuracy, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and complication rates were statistically evaluated. Influencing factors (patient age, sex, lesion size, pleural-puncture angle, patient position, pleural effusion, and number of pleural punctures) were assessed for their effect on accuracy of CT-guided CNB using univariate and subsequent multivariate analysis. Diagnostic accuracy, sensitivity, specificity, PPV, and NPV were 89.2%, 86.1%, 100%, 100%, and 67.8%, respectively. The influencing factors had no significant effect in altering diagnostic accuracy. As far as complications were concerned, occurrence of pneumothorax was observed in 14 (16%) out of 88 patients. Multivariate analysis revealed lesion size/pleural thickening as a significant risk factor (odds ratio [OR]: 8.744, p = 0.005) for occurrence of pneumothorax. Moreover, presence of pleural effusion was noted as a significant protective factor (OR: 0.171, p = 0.037) for pneumothorax. CT-guided CNB of pleural lesion is a safe procedure with high diagnostic yield and low risk of significant complications.

  2. CT-guided core needle biopsy of pleural lesions: Evaluating diagnostic yield and associated complications

    Energy Technology Data Exchange (ETDEWEB)

    Niu, Xiang Ke [Dept. of Radiology, Affiliated Hospital of Chengdu University, Chengdu (China); Bhetuwal, Anup; Yang, Han Feng [Dept. of Radiology, Sichuan Key Laboratory of Medical Imaging, Affiliated Hospital of North Sichuan Medical College, Nanchong (China)

    2015-02-15

    The purpose of this study was to retrospectively evaluate the diagnostic accuracy and complications of CT-guided core needle biopsy (CT-guided CNB) of pleural lesion and the possible effects of influencing factors. From September 2007 to June 2013, 88 consecutive patients (60 men and 28 women; mean [+/- standard deviation] age, 51.1 +/- 14.4 years; range, 19-78 years) underwent CT-guided CNB, which was performed by two experienced chest radiologists in our medical center. Out of 88 cases, 56 (63%) were diagnosed as malignant, 28 (31%) as benign and 4 (5%) as indeterminate for CNB of pleural lesions. The final diagnosis was confirmed by either histopathological diagnosis or clinical follow-up. The diagnostic accuracy, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and complication rates were statistically evaluated. Influencing factors (patient age, sex, lesion size, pleural-puncture angle, patient position, pleural effusion, and number of pleural punctures) were assessed for their effect on accuracy of CT-guided CNB using univariate and subsequent multivariate analysis. Diagnostic accuracy, sensitivity, specificity, PPV, and NPV were 89.2%, 86.1%, 100%, 100%, and 67.8%, respectively. The influencing factors had no significant effect in altering diagnostic accuracy. As far as complications were concerned, occurrence of pneumothorax was observed in 14 (16%) out of 88 patients. Multivariate analysis revealed lesion size/pleural thickening as a significant risk factor (odds ratio [OR]: 8.744, p = 0.005) for occurrence of pneumothorax. Moreover, presence of pleural effusion was noted as a significant protective factor (OR: 0.171, p = 0.037) for pneumothorax. CT-guided CNB of pleural lesion is a safe procedure with high diagnostic yield and low risk of significant complications.

  3. Fast 3-T MR-guided transrectal prostate biopsy using an in-room tablet device for needle guide alignment: a feasibility study.

    Science.gov (United States)

    Overduin, Christiaan G; Heidkamp, Jan; Rothgang, Eva; Barentsz, Jelle O; de Lange, Frank; Fütterer, Jurgen J

    2018-05-22

    To assess the feasibility of adding a tablet device inside the scanner room to assist needle-guide alignment during magnetic resonance (MR)-guided transrectal prostate biopsy. Twenty patients with one cancer-suspicious region (CSR) with PI-RADS score ≥ 4 on diagnostic multiparametric MRI were prospectively enrolled. Two orthogonal scan planes of an MR fluoroscopy sequence (~3 images/s) were aligned to the CSR and needle-guide pivoting point. Targeting was achieved by manipulating the needle-guide under MR fluoroscopy feedback on the in-room tablet device. Technical feasibility and targeting success were assessed. Complications and biopsy procedure times were also recorded. Needle-guide alignment with the in-room tablet device was technically successful in all patients and allowed sampling after a single alignment step in 19/20 (95%) CSRs (median size 14 mm, range: 4-45). Biopsy cores contained cancer in 18/20 patients. There were no per-procedural or post-biopsy complications. Using the tablet device, the mean time to first biopsy was 5.8 ± 1.0 min and the mean total procedure time was 23.7 ± 4.1 min. Use of an in-room tablet device to assist needle-guide alignment was feasible and safe during MR-guided transrectal prostate biopsy. Initial experience indicates potential for procedure time reduction. • Performing MR-guided prostate biopsy using an in-room tablet device is feasible. • CSRs could be sampled after a single alignment step in 19/20 patients. • The mean procedure time for biopsy with the tablet device was 23.7 min.

  4. Computed-Tomography-Guided Percutaneous Core Needle Biopsies of Suspected Malignant Lymphomas: Impact of Biopsy, Lesion, and Patient Parameters on Diagnostic Yield

    International Nuclear Information System (INIS)

    Hesselmann, V.; Zaehringer, M.; Krug, B.; Wesselmann, C.; Haferkamp, K.; Wickenhauser, C.; Lackner, K.

    2004-01-01

    Purpose: To investigate the diagnostic yield of core needle biopsy in patients with malignant lymphoma. Material and Methods: Computed-tomography-guided core needle biopsies in patients with malignant lymphoma performed in the period 1996 to 2001 were evaluated retrospectively. A biopsy was considered as 'fully diagnostic' if a histological diagnosis, including the histologic subtype in the event of malignant lymphoma, was achieved and the clinical course and CT follow-up of at least 6 months confirmed the biopsy results. A biopsy was regarded as 'partly diagnostic' if histological work-up defined malignant lymphoma but not the histological subtype, and if histological diagnosis bore therapeutic relevance. Diagnostic yield was correlated with features such as size of specimen, location and depth of the target lesion, and experience of the investigator. Results: 45 biopsies were performed in 40 patients. With respect to definite histopathological diagnosis, 31 biopsies (68.9%) were diagnostic and 14 (31.1%) non-diagnostic. In 4 cases (8.8%), biopsies yielded partly diagnostic results, since therapy could be scheduled after biopsy without final sub-classification. Statistical analysis of biopsy parameters revealed that sample sizes were significantly larger in the diagnostic group. Conclusion: CT-guided biopsy can be considered as an alternative for lymphoma diagnosis and should be the first interventional procedure. The most important parameter for diagnostic success is the size of the specimen

  5. Clinical Value of CT-Guided Needle Biopsy for Retroperitoneal Lesions

    International Nuclear Information System (INIS)

    Tomozawa, Yuki; Inaba, Yoshitaka; Yamaura, Hidekazu; Sato, Yozo; Kato, Mina; Kanamoto, Takaaki; Sakane, Makoto

    2011-01-01

    The purpose of this study was to investigate retrospectively the clinical procedural performance of CT-guided needle biopsy for retroperitoneal lesions. CT-guided needle biopsy was performed in 74 consecutive patients (M:F = 44:30; mean age, 59.7 years) with retroperitoneal lesions between April 1998 and June 2009. The target lesion ranged from 1.5 to 12.5 cm in size. The biopsy access path ranged from 3.5 to 11.5 cm in depth. A biopsy specimen was obtained using an 18-gauge core needle under a CT or CT-fluoroscopy guidance and with the patient under local anesthesia. The histopathological diagnoses from the biopsies were obtained. The diagnostic confirmation of the subtype of lymphoma was evaluated. Satisfactory biopsy samples were obtained in 73 (99%) of 74 patients and a pathological diagnosis was made in 70 (95%) of 74 patients. Sixty three lesions were malignant (45 lymphomas, nine primary tumors, nine lymph node metastases) and seven were benign. The subtype of lymphoma was specified in 43 (96%) of 45 patients who were diagnosed with lymphoma. Analysis of the value of CT-guided biopsy in this series indicated 63 true positives, zero false positive, six true negatives and five false negatives. This test had a sensitivity of 93%, a specificity of 100% and an accuracy of 93%. No major complications were seen and minor complications were noted in seven patients (five with local hematomas, two with transient pain at the puncture site). CT-guided needle biopsy for retroperitoneal lesions is highly practical and useful, and particularly for determining the subtypes in patients with lymphoma.

  6. CT fluoroscopy guided transpleural cutting needle biopsy of small ({<=}2.5 cm) subpleural pulmonary nodules

    Energy Technology Data Exchange (ETDEWEB)

    Prosch, Helmut; Oschatz, Elisabeth; Eisenhuber, Edith; Wohlschlager, Helmut [Otto Wagner Hospital, Department of Radiology, Sanatoriumsstrasse 2, 1140 Vienna (Austria); Mostbeck, Gerhard H., E-mail: gerhard.mostbeck@wienkav.at [Otto Wagner Hospital, Department of Radiology, Sanatoriumsstrasse 2, 1140 Vienna (Austria)

    2011-01-15

    Purpose: Small subpleural pulmonary lesions are difficult to biopsy. While the direct, short needle path has been reported to have a lower rate of pneumothorax, the indirect path provides a higher diagnostic yield. Therefore, we tried to optimize the needle pathway and minimize the iatrogenic pneumothorax risk by evaluating a CT fluoroscopy guided direct approach to biopsy subpleural lesions. Material and methods: Between 01/2005 and 01/2007, CT fluoroscopy guided core biopsies were performed in 24 patients. Using our technique, the tip of the guide needle remains outside the visceral pleura (17 G coaxial guide needle, 18 G Biopsy-gun, 15 or 22 mm needle path). The position of the lesion relative to the needle tip can be optimized using CT fluoroscopy by adjusting the breathing position of the patient. The Biopty gun is fired with the needle tip still outside the pleural space. Cytological smears are analyzed by a cytopathologist on-site, and biopsies are repeated as indicated with the coaxial needle still outside the pleura. Results: Median nodule size was 1.6 cm (0.7-2.3 cm). A definitive diagnosis was obtained in 22 patients by histology and/or cytology. In one patient, only necrotic material could be obtained. In another patient, the intervention had to be aborted as the dyspnoic patient could not follow breathing instructions. An asymptomatic pneumothorax was present in seven patients; chest tube placement was not required. Conclusion: The presented biopsy approach has a high diagnostic yield and is especially advantageous for biopsies of small subpleural lesions in the lower lobes.

  7. Computed tomography-guided needle biopsy of lung lesions in fourteen cats and dogs

    International Nuclear Information System (INIS)

    Yoshida, K.; Mori, T.; Yamada, M.; Sakaida, M.; Yonemaru, K.; Murakami, M.; Sakai, H.; Maruo, K.

    2007-01-01

    Computed tomography (CT)-guided fine-needle aspirates (FNA) or core biopsies of lung lesions were performed in nine dogs and five cats. A clinical diagnosis was obtained in twelve of fourteen animals (85%), namely 80% FNA and 100% core biopsies. Eight animals had other mass (es) apart from the lung, and five were diagnosed to metastases. In only one case, the lung mass was histopathologically diagnosed as a malignant primary tumor. Iatrogenic complications through the lung biopsies were noted in four animals, and three showed mild pneumothorax on CT images and one was bleeding from the needle. However, between fifteen and thirty minutes after the biopsy, no animal indicated signs of pneumothorax or hemorrhage

  8. Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid An ... Aspiration Biopsy of the Thyroid? What is Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid? During ...

  9. Feasibility of computed tomography-guided core needle biopsy in producing state-of-the-art clinical management in Chinese lung cancer.

    Science.gov (United States)

    Chen, Hua-Jun; Yang, Jin-Ji; Fang, Liang-Yi; Huang, Min-Min; Yan, Hong-Hong; Zhang, Xu-Chao; Xu, Chong-Rui; Wu, Yi-Long

    2014-03-01

    A satisfactory biopsy determines the state-of-the-art management of lung cancer in this era of personalized medicine. This study aimed to investigate the suitability and efficacy of computed tomography (CT)-guided core needle biopsy in clinical management. A cohort of 353 patients with clinically suspected lung cancer was enrolled in the study. Patient factors and biopsy variables were recorded. Epidermal growth factor receptor (EGFR) gene mutations and echinoderm microtubule-associated protein-like 4 (EML4)-anaplastic lymphoma kinase (ALK) rearrangement were detected in tumor specimens. Adequacy of biopsic obtainment for clinical trial screening and tissue bank establishment were reviewed. Overall diagnostic accuracy of malignancy achieved 98.5%. The median biopsy time of the cohort was 20 minutes. In patients with non-small cell lung cancer (NSCLC), 99.3% (287/289) were diagnosed as specific histologic subtypes, and two patients (0.7%) were determined as NSCLC not otherwise specified (NOS). EGFR mutations were analyzed in 81.7% (236/289) of patients with NSCLC, and 98.7% (233/236) showed conclusive results. EML4-ALK gene fusion was tested in 43.9% (127/289) of NSCLC patients, and 98.4% (125/127) showed conclusive results: 6.4% (8/125) of those had gene fusion. Ninety-six NSCLC patients participated in clinical trial screening and provided mandatory tumor slides for molecular profiling. Pathological evaluation was fulfilled in 90 patients (93.8%); 99.4% (320/322) of patients with malignancy provided extra tissue for the establishment of a tumor bank. CT-guided core needle biopsy provided optimal clinical management in this era of translational medicine. The biopsic modality should be prioritized in selected lung cancer patients.

  10. New radiofrequency device to reduce bleeding after core needle biopsy: Experimental study in a porcine liver model

    International Nuclear Information System (INIS)

    Lim, Sang Hyeok; Rhim, Hyun Chul; Lee, Min Woo; Song, Kyoung Doo; Kang, Tae Wook; Kim, Young Sun; Lim, Hyo Keun

    2017-01-01

    To evaluate the in vivo efficiency of the biopsy tract radiofrequency ablation for hemostasis after core biopsy of the liver in a porcine liver model, including situations with bleeding tendency and a larger (16-gauge) core needle. A preliminary study was performed using one pig to determine optimal ablation parameters. For the main experiment, four pigs were assigned to different groups according to heparinization use and biopsy needle caliber. In each pig, 14 control (without tract ablation) and 14 experimental (tract ablation) ultrasound-guided core biopsies were performed using either an 18- or 16-gauge needle. Post-biopsy bleeding amounts were measured by soaking up the blood for five minutes. The results were compared using the Mann-Whitney U test. The optimal parameters for biopsy tract ablation were determined as a 2-cm active tip electrode set at 40-watt with a tip temperature of 70–80℃. The bleeding amounts in all experimental groups were smaller than those in the controls; however they were significant in the non-heparinized pig biopsied with an 18-gauge needle and in two heparinized pigs (p < 0.001). In the heparinized pigs, the mean blood loss in the experimental group was 3.5% and 13.5% of the controls biopsied with an 18- and 16-gauge needle, respectively. Radiofrequency ablation of hepatic core biopsy tract ablation may reduce post-biopsy bleeding even under bleeding tendency and using a larger core needle, according to the result from in vivo porcine model experiments

  11. New radiofrequency device to reduce bleeding after core needle biopsy: Experimental study in a porcine liver model

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Sang Hyeok; Rhim, Hyun Chul; Lee, Min Woo; Song, Kyoung Doo; Kang, Tae Wook; Kim, Young Sun; Lim, Hyo Keun [Dept. of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2017-01-15

    To evaluate the in vivo efficiency of the biopsy tract radiofrequency ablation for hemostasis after core biopsy of the liver in a porcine liver model, including situations with bleeding tendency and a larger (16-gauge) core needle. A preliminary study was performed using one pig to determine optimal ablation parameters. For the main experiment, four pigs were assigned to different groups according to heparinization use and biopsy needle caliber. In each pig, 14 control (without tract ablation) and 14 experimental (tract ablation) ultrasound-guided core biopsies were performed using either an 18- or 16-gauge needle. Post-biopsy bleeding amounts were measured by soaking up the blood for five minutes. The results were compared using the Mann-Whitney U test. The optimal parameters for biopsy tract ablation were determined as a 2-cm active tip electrode set at 40-watt with a tip temperature of 70–80℃. The bleeding amounts in all experimental groups were smaller than those in the controls; however they were significant in the non-heparinized pig biopsied with an 18-gauge needle and in two heparinized pigs (p < 0.001). In the heparinized pigs, the mean blood loss in the experimental group was 3.5% and 13.5% of the controls biopsied with an 18- and 16-gauge needle, respectively. Radiofrequency ablation of hepatic core biopsy tract ablation may reduce post-biopsy bleeding even under bleeding tendency and using a larger core needle, according to the result from in vivo porcine model experiments.

  12. Imprint cytology from ultrasound-guided core biopsies: accurate and immediate diagnosis in a one-stop breast clinic

    International Nuclear Information System (INIS)

    Jones, L.; Lott, M.F.; Calder, C.J.; Kutt, E.

    2004-01-01

    AIM: To investigate whether imprint cytology from ultrasound-guided core biopsy specimens was adequate for the National Health Service Breast Screening Programme (NHSBSP) guidelines. METHODS: We prospectively audited imprint cytology from ultrasound-guided core biopsy specimens. The performance indicators for imprint cytology specimens from 111 consecutive ultrasound-guided core biopsy were compared with standards set by the NHSBSP for fine-needle aspiration cytology (FNAC). RESULTS: Imprint cytology fulfilled the 'preferred' targets for absolute and complete sensitivity, specificity, positive predictive value, false-positive and false-negative rates, inadequate rate and inadequate rate from cancers. It also satisfied the minimum target for suspicious rate. The complete sensitivity was 97%, full specificity 78%, with 100% positive predictive value for C5 cytology and an inadequate rate from cancers of 1.5%. CONCLUSION: Imprint cytology from ultrasound-guided core biopsy allows same-day diagnosis and the collection of data regarding the grade of the carcinoma for treatment decisions from a single needle test

  13. Smartphone-Guided Needle Angle Selection During CT-Guided Procedures.

    Science.gov (United States)

    Xu, Sheng; Krishnasamy, Venkatesh; Levy, Elliot; Li, Ming; Tse, Zion Tsz Ho; Wood, Bradford John

    2018-01-01

    In CT-guided intervention, translation from a planned needle insertion angle to the actual insertion angle is estimated only with the physician's visuospatial abilities. An iPhone app was developed to reduce reliance on operator ability to estimate and reproduce angles. The iPhone app overlays the planned angle on the smartphone's camera display in real-time based on the smartphone's orientation. The needle's angle is selected by visually comparing the actual needle with the guideline in the display. If the smartphone's screen is perpendicular to the planned path, the smartphone shows the Bull's-Eye View mode, in which the angle is selected after the needle's hub overlaps the tip in the camera. In phantom studies, we evaluated the accuracies of the hardware, the Guideline mode, and the Bull's-Eye View mode and showed the app's clinical efficacy. A proof-of-concept clinical case was also performed. The hardware accuracy was 0.37° ± 0.27° (mean ± SD). The mean error and navigation time were 1.0° ± 0.9° and 8.7 ± 2.3 seconds for a senior radiologist with 25 years' experience and 1.5° ± 1.3° and 8.0 ± 1.6 seconds for a junior radiologist with 4 years' experience. The accuracy of the Bull's-Eye View mode was 2.9° ± 1.1°. Combined CT and smart-phone guidance was significantly more accurate than CT-only guidance for the first needle pass (p = 0.046), which led to a smaller final targeting error (mean distance from needle tip to target, 2.5 vs 7.9 mm). Mobile devices can be useful for guiding needle-based interventions. The hardware is low cost and widely available. The method is accurate, effective, and easy to implement.

  14. Investigation of tissue cellularity at the tip of the core biopsy needle with optical coherence tomography.

    Science.gov (United States)

    Iftimia, Nicusor; Park, Jesung; Maguluri, Gopi; Krishnamurthy, Savitri; McWatters, Amanda; Sabir, Sharjeel H

    2018-02-01

    We report the development and the pre-clinical testing of a new technology based on optical coherence tomography (OCT) for investigating tissue composition at the tip of the core biopsy needle. While ultrasound, computed tomography, and magnetic resonance imaging are routinely used to guide needle placement within a tumor, they still do not provide the resolution needed to investigate tissue cellularity (ratio between viable tumor and benign stroma) at the needle tip prior to taking a biopsy core. High resolution OCT imaging, however, can be used to investigate tissue morphology at the micron scale, and thus to determine if the biopsy core would likely have the expected composition. Therefore, we implemented this capability within a custom-made biopsy gun and evaluated its capability for a correct estimation of tumor tissue cellularity. A pilot study on a rabbit model of soft tissue cancer has shown the capability of this technique to provide correct evaluation of tumor tissue cellularity in over 85% of the cases. These initial results indicate the potential benefit of the OCT-based approach for improving the success of the core biopsy procedures.

  15. An ultrasound needle insertion guide in a porcine phantom model.

    Science.gov (United States)

    Whittaker, S; Lethbridge, G; Kim, C; Keon Cohen, Z; Ng, I

    2013-08-01

    We compared nerve blockade with and without the Infiniti(TM) needle guide in an ultrasound in-plane porcine simulation. We recruited 30 anaesthetists with varying blockade experience. Using the guide, the needle tip was more visible (for a median (IQR [range]) of 67 (56-100]) % of the time; and invisible for 2 (1-4 [0-19]) s) than when the guide was not used (respectively 23 (13-43 [0-80]) % and 25 (9-52 [1-198]) s; both p < 0.001). The corresponding block times were 8 (6-10 [3-28]) s and 32 (15-67 [5-225]) s, respectively; p < 0.001. The needle guide reduced the block time and the time that the needle was invisible, irrespective of anaesthetist experience. Anaesthesia © 2013 The Association of Anaesthetists of Great Britain and Ireland.

  16. CT-guided percutaneous core needle biopsy for small (≤20 mm) pulmonary lesions

    International Nuclear Information System (INIS)

    Li, Y.; Du, Y.; Yang, H.F.; Yu, J.H.; Xu, X.X.

    2013-01-01

    Aim: To assess the accuracy and risk factors for complications of computed tomography (CT)-guided percutaneous core needle biopsy (CNB) for small (≤20 mm) pulmonary lesions. Materials and methods: A retrospective study was undertaken comprising 169 patients who underwent CT-guided CNB for small (≤20 mm) pulmonary lesions. To assess the accuracy of the procedure, the diagnosis at biopsy was compared with the diagnosis after definitive surgery or clinical follow-up. The risk factors for pneumothorax and bleeding were determined by multivariate analysis of variables. Results: The overall diagnostic accuracy was 93.5%. The sensitivity for malignancy and specificity for benign lesions were 90.4% and 100%, respectively. Positive and negative predictive values were 100% and 83.3%, respectively. Twenty-five patients (14.8%) had pneumothorax after CT percutaneous CNB of the lung. The significant risk factors affecting the incidence of pneumothorax were lesion–pleural distance (p = 0.008) and needle–pleural angle (p = 0.012). The highest rate of pneumothorax correlated with a lesion–pleural distance ≥21 mm (OR = 18.46; 95%CI: 2.27–149.95) and a needle–pleural angle ≥51° (OR = 8.22; 95%CI: 2.14–31.49). Bleeding occurred in 30 patients (17.8%). The only significant risk factor affecting the incidence of bleeding was lesion–pleural distance (p = 0.011). The highest bleeding rate correlated with a lesion–pleural distance ≥21 mm (OR = 7.93; 95%CI: 1.73–36.43). Conclusion: CT-guided percutaneous CNB of small (≤20 mm) pulmonary lesions provides high diagnostic accuracy with acceptable complications. A lesion–pleural distance of ≥21 mm and needle–pleural angle of ≥51° are identified as the risk factors for highest pneumothorax rate. In addition, the needle–pleural angle is a novel predictor of pneumothorax. A lesion–pleural distance of ≥21 mm is also identified as a risk factor for the highest bleeding rate.

  17. Computed tomography guided needle biopsy: experience from 1,300 procedures

    Energy Technology Data Exchange (ETDEWEB)

    Chojniak, Rubens; Isberner, Rony Klaus; Viana, Luciana Marinho; Yu, Liao Shin; Aita, Alessandro Amorim; Soares, Fernando Augusto [Hospital do Cancer A.C. Camargo, Sao Paulo, SP (Brazil). Dept. de Radiologia e Patologia

    2006-01-15

    Context and objective: computed tomography (CT) guided biopsy is widely accepted as effective and safe for diagnosis in many settings. Accuracy depends on target organ and needle type. Cutting needles present advantages over fine needles. This study presents experience from CT guided biopsies performed at an oncology center. Design and setting: retrospective study at Hospital do Cancer A. C. Camargo, Sao Paulo.Methods: 1,300 consecutive CT guided biopsies performed between July 1994 and February 2000 were analyzed. Nodules or masses were suspected as primary malignancy in 845 cases (65%) or metastatic lesion in 455 (35%). 628 lesions were thoracic, 281 abdominal, 208 retroperitoneal, 134 musculoskeletal and 49 head/neck. All biopsies were performed by one radiologist or under his supervision: 765 (59%) with 22-gauge fine-needle/aspiration technique and 535 (41%) with automated 16 or 18-gauge cutting-needle biopsy. Results: adequate samples were obtained in 70-92% of fine-needle and 93-100% of cutting-needle biopsies. The specific diagnosis rates were 54-67% for fine-needle and 82-100% for cutting-needle biopsies, according to biopsy site. For any site, sample adequacy and specific diagnosis rate were always better for cutting-needle biopsy. Among 530 lung biopsies, there were 84 pneumothorax (16%) and two hemothorax (0.3%) cases, with thoracic drainage in 24 (4.9%). Among abdominal and retroperitoneal biopsies, there were two cases of major bleeding and one of peritonitis. Conclusion: both types of needle showed satisfactory results, but cutting-needle biopsy should be used when specific diagnosis is desired without greater incidence of complications. (author)

  18. Use of percutaneous image-guided coaxial core-needle biopsy for diagnosis of intraabdominal lymphoma

    International Nuclear Information System (INIS)

    Shimizu, Ikuo; Okazaki, Yoichi; Takeda, Wataru; Kirihara, Takehiko; Sato, Keijiro; Fujikawa, Yuko; Ueki, Toshimitsu; Hiroshima, Yuki; Sumi, Masahiko; Ueno, Mayumi; Ichikawa, Naoaki; Kobayashi, Hikaru

    2014-01-01

    Although pathological diagnosis is essential for managing malignant lymphoma, intraabdominal lesions are generally difficult to approach due to the invasiveness of abdominal surgery. Here, we report the use of percutaneous image-guided coaxial core-needle biopsy (CNB) to obtain intraabdominal specimens for diagnosing intraabdominal lymphomas, which typically requires histopathological and immunohistochemical evaluation. We retrospectively reviewed consecutive cases involving computed tomography (CT)- or ultrasonography (US)-guided CNB to obtain pathological specimens for intraabdominal lesions from 1999 to 2011. Liver, spleen, kidney, and inguinal node biopsies were excluded. We compared CNBs with laparotomic biopsies. A total of 66 CNBs were performed for 59 patients (32 males, 27 females; median age, 63.5), including second or third repeat procedures. Overall diagnostic rate was 88.5%. None of the patients required additional surgical biopsies. Notably, the median interval between recognition of an intraabdominal mass and biopsy was only 1 day. Forty-five procedures were performed for hematological malignancies. Adequate specimens were obtained for histopathological diagnosis in 86% of cases. Flow cytometry detected lymphoma cells in 79.5% of cases. Twelve patients (nine males, three females; median age, 60) were eligible for surgical biopsy. While every postoperative course was satisfactory, median duration from lesion recognition to therapy initiation for lymphoma cases was significantly shorter for CNB than for surgical biopsy (14 vs. 35 days). While one-fourth of the patients were not eligible for the procedures, CNB is safe and highly effective for diagnosis of intraabdominal lymphomas. This method significantly improves sampling and potentially helps attain immunohistological distinction, allowing for more timely therapy initiation

  19. Histological diagnosis of ultrasound-visible breast lesions by large core needle biopsy

    International Nuclear Information System (INIS)

    Sanchis-Querol, E.; Valeros, O.; Collado, A.; Gimenez, J.; Yanguas, C.

    1999-01-01

    We present our experience in the histological diagnosis of breast lesions using ultrasound-guided large core needle biopsy (LCNB), assessing its utility as an alternative to excisional biopsy. We have studied retrospectively a series of 146 cases involving the performance of LCNB. The results were comparable with those of FNAB in 59 cases and with those of surgical aspiration biopsy in 105. Of the 113 lesions identified as malignant by percutaneous large core needle aspiration biopsy, 96 were resected. Surgical aspiration biopsy agreed with LCNB in 100% of cases. Of the 33 lesions identified as benign by LCNB, surgical biopsy detected malignancy in 5. The results obtained establish a specificity for LCNB of 100% and a sensitivity of 96%, both of which are superior to the values for FNAB. Thus, this technique can be considered valid for preoperative diagnosis. LCNB is useful in the preoperative diagnosis of breast lesions, making FNAB and surgical biopsy unnecessary. Moreover, it constitutes a significant change in the management of patients with malignant or undetermined breast lesions. (Author) 8 refs

  20. CT-guided biopsy of thoracic lesions with a novel wire-based needle guide device - initial experiences

    Energy Technology Data Exchange (ETDEWEB)

    Kroepil, Patric; Bilk, Philip; Quentin, Michael; Miese, Falk R; Lanzman, Rotem S; Scherer, Axel (Dept. of Radiology, Medical Faculty, Univ. Duesseldorf, Duesseldorf (Germany)), email: Patric.Kroepil@med.uni-duesseldorf.de

    2011-10-15

    Background Biopsies guided by computed tomography (CT) play an important role in clinical practice. A short duration, minimal radiation dose and complication rate are of particular interest. Purpose To evaluate the potential of a novel self-manufactured wire-based needle guide device for CT-guided thoracic biopsies with respect to radiation dose, intervention time and complication rate. Material and Methods Forty patients that underwent CT-guided biopsies of thoracic lesions were included in this study and assigned to two groups. Patients in group A (n = 20, mean age 69 +- 8.4 years) underwent biopsies with a novel wire-based needle guide device, while patients in group B (n = 20, mean age 68.4 +- 10.1 years) were biopsied without a needle guide device. The novel self-manufactured needle guide device consists of an iron/zinc wire modelled to a ring with a flexible arm and an eye at the end of the arm to stabilize the biopsy needle in the optimal position during intervention. Predefined parameters (radiation dose, number of acquired CT-slices, duration of intervention, complications) were compared between both groups. Results Mean radiation dose (CTDIvol 192 mGy versus 541 mGy; P = 0.001) and the number of acquired slices during intervention (n = 49 +- 33 vs. n = 126 +- 78; P = 0.001) were significantly lower in group A compared with group B. Intervention time in group A (13.1 min) was significantly lower than in group B (18.5 min, P < 0.01). A pneumothorax as peri-interventional complication was observed less frequent after device assisted biopsies (n = 4 vs. n = 8, n.s.). Conclusion The novel wire-based needle guide device is a promising tool to facilitate CT-guided thoracic biopsies reducing radiation dose, intervention time, and related complications. Further studies are mandatory to confirm these initial results

  1. CT-guided biopsy of thoracic lesions with a novel wire-based needle guide device - initial experiences

    International Nuclear Information System (INIS)

    Kroepil, Patric; Bilk, Philip; Quentin, Michael; Miese, Falk R; Lanzman, Rotem S; Scherer, Axel

    2011-01-01

    Background Biopsies guided by computed tomography (CT) play an important role in clinical practice. A short duration, minimal radiation dose and complication rate are of particular interest. Purpose To evaluate the potential of a novel self-manufactured wire-based needle guide device for CT-guided thoracic biopsies with respect to radiation dose, intervention time and complication rate. Material and Methods Forty patients that underwent CT-guided biopsies of thoracic lesions were included in this study and assigned to two groups. Patients in group A (n = 20, mean age 69 ± 8.4 years) underwent biopsies with a novel wire-based needle guide device, while patients in group B (n = 20, mean age 68.4 ± 10.1 years) were biopsied without a needle guide device. The novel self-manufactured needle guide device consists of an iron/zinc wire modelled to a ring with a flexible arm and an eye at the end of the arm to stabilize the biopsy needle in the optimal position during intervention. Predefined parameters (radiation dose, number of acquired CT-slices, duration of intervention, complications) were compared between both groups. Results Mean radiation dose (CTDIvol 192 mGy versus 541 mGy; P = 0.001) and the number of acquired slices during intervention (n = 49 ± 33 vs. n = 126 ± 78; P = 0.001) were significantly lower in group A compared with group B. Intervention time in group A (13.1 min) was significantly lower than in group B (18.5 min, P < 0.01). A pneumothorax as peri-interventional complication was observed less frequent after device assisted biopsies (n = 4 vs. n = 8, n.s.). Conclusion The novel wire-based needle guide device is a promising tool to facilitate CT-guided thoracic biopsies reducing radiation dose, intervention time, and related complications. Further studies are mandatory to confirm these initial results

  2. Lesion stiffness measured by shear-wave elastography: Preoperative predictor of the histologic underestimation of US-guided core needle breast biopsy.

    Science.gov (United States)

    Park, Ah Young; Son, Eun Ju; Kim, Jeong-Ah; Han, Kyunghwa; Youk, Ji Hyun

    2015-12-01

    To determine whether lesion stiffness measured by shear-wave elastography (SWE) can be used to predict the histologic underestimation of ultrasound (US)-guided 14-gauge core needle biopsy (CNB) for breast masses. This retrospective study enrolled 99 breast masses from 93 patients, including 40 high-risk lesions and 59 ductal carcinoma in situ (DCIS), which were diagnosed by US-guided 14-gauge CNB. SWE was performed for all breast masses to measure quantitative elasticity values before US-guided CNB. To identify the preoperative factors associated with histologic underestimation, patients' age, symptoms, lesion size, B-mode US findings, and quantitative SWE parameters were compared according to the histologic upgrade after surgery using the chi-square test, Fisher's exact test, or independent t-test. The independent factors for predicting histologic upgrade were evaluated using multivariate logistic regression analysis. The underestimation rate was 28.3% (28/99) in total, 25.0% (10/40) in high-risk lesions, and 30.5% (18/59) in DCIS. All elasticity values of the upgrade group were significantly higher than those of the non-upgrade group (PBreast lesion stiffness quantitatively measured by SWE could be helpful to predict the underestimation of malignancy in US-guided 14-gauge CNB. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  3. Endoscopic Ultrasound Guided Rendezvous Drainage of Biliary Obstruction Using a New Flexible 19-Gauge Fine Needle Aspiration Needle.

    Science.gov (United States)

    Tang, Zhouwen; Igbinomwanhia, Efehi; Elhanafi, Sherif; Othman, Mohamed O

    2016-01-01

    Background and Aim. A successful endoscopic ultrasound guided rendezvous (EUS-RV) biliary drainage is dependent on accurate puncture of the bile duct and precise guide wire manipulation across the ampulla of Vater. We aim to study the feasibility of using a flexible 19-gauge fine aspiration needle in the performance of EUS-RV biliary drainage. Method. This is a retrospective case series of EUS-RV biliary drainage procedures at a single center. Patients who failed ERCP during the same session for benign or malignant biliary obstruction underwent EUS-RV using a flexible, nitinol covered, 19-gauge needle for biliary access and guide wire manipulation. Result. 24 patients underwent EUS-RV biliary drainage via extrahepatic access while 1 attempt was via intrahepatic access. The technical success rate was 80%, including 83.3% of cases via extrahepatic access. There was no significant difference in success rate of inpatient and outpatient procedures, benign or malignant indications, or type of guide wire used. Adverse events included mild pancreatitis (3 patients) and cholangitis (1 patient). Conclusion. A flexible 19-gauge needle for biliary access can be safe and effective when used to perform EUS-RV biliary drainage. Direct comparison between the nitinol needle and conventional metal needles in the performance of EUS guided biliary drainage is needed.

  4. Use of CT-guided fine needle aspiration biopsy in epidermal growth factor receptor mutation analysis in patients with advanced lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Zhuang, Yi-Ping; Wang, Hai-Yan; Zhang, Jin; Feng, Yong (Dept. of Radiology, Jiangsu Cancer Inst. and Hospital, Nanjing, Jiangsu (China)), email: yipingzhuang2010@sina.com; Shi, Mei-Qi (Dept. of Chemotherapy, Jiangsu Cancer Inst. and Hospital, Nanjing, Jiangsu (China))

    2011-12-15

    Background. The safety of using a cutting needle when performing a core-needle biopsy is of major concern, in particular for small lung tumors or tumors near the hilum. Purpose. To investigate the usefulness of CT-guided fine needle aspiration biopsy (FNAB) of the lung in obtaining tumor tissue for epidermal growth factor receptor (EGFR) mutation analysis in advanced lung cancer patients. Material and Methods. Forty-three patients with stage IIIB-IV lung cancer were enrolled. In all patients, CT-guided FNAB was performed using an 18-gauge or 20-gauge Chiba aspiration needle for histology diagnosis and EGFR mutation analysis. Complications associated with CT-guided FNAB were observed, and the specimen mutational assessments were recorded. Results. The obtained tumor samples ranged from 0.5-1.5 cm in length and were adequate for histological and DNA analyses in all patients. No patient had a pneumothorax or hemoptysis. Minor needle tract bleeding appeared in eight patients. Mutation analysis was satisfactorily demonstrated in 23 mutations and 20 non-mutations. Ten and 13 mutations were identified by 18-gauge and 20-gauge needle biopsies, respectively. EFGR mutations, including 12 cases of EGFR exon 19 deletion and 11 cases of exon 21 point mutation, were present in 21 patients with adenocarcinomas, one with squamous cell carcinoma, and one with undifferentiated carcinoma. Conclusion. CT-guided FNAB is a feasible and safe technique for obtaining lung tumor tissues for EGFR gene mutation analysis

  5. Determining the Optimal Number of Core Needle Biopsy Passes for Molecular Diagnostics.

    Science.gov (United States)

    Hoang, Nam S; Ge, Benjamin H; Pan, Lorraine Y; Ozawa, Michael G; Kong, Christina S; Louie, John D; Shah, Rajesh P

    2018-03-01

    The number of core biopsy passes required for adequate next-generation sequencing is impacted by needle cut, needle gauge, and the type of tissue involved. This study evaluates diagnostic adequacy of core needle lung biopsies based on number of passes and provides guidelines for other tissues based on simulated biopsies in ex vivo porcine organ tissues. The rate of diagnostic adequacy for pathology and molecular testing from lung biopsy procedures was measured for eight operators pre-implementation (September 2012-October 2013) and post-implementation (December 2013-April 2014) of a standard protocol using 20-gauge side-cut needles for ten core biopsy passes at a single academic hospital. Biopsy pass volume was then estimated in ex vivo porcine muscle, liver, and kidney using side-cut devices at 16, 18, and 20 gauge and end-cut devices at 16 and 18 gauge to estimate minimum number of passes required for adequate molecular testing. Molecular diagnostic adequacy increased from 69% (pre-implementation period) to 92% (post-implementation period) (p < 0.001) for lung biopsies. In porcine models, both 16-gauge end-cut and side-cut devices require one pass to reach the validated volume threshold to ensure 99% adequacy for molecular characterization, while 18- and 20-gauge devices require 2-5 passes depending on needle cut and tissue type. Use of 20-gauge side-cut core biopsy needles requires a significant number of passes to ensure diagnostic adequacy for molecular testing across all tissue types. To ensure diagnostic adequacy for molecular testing, 16- and 18-gauge needles require markedly fewer passes.

  6. Comparison of 22G reverse-beveled versus standard needle for endoscopic ultrasound-guided sampling of solid pancreatic lesions

    Science.gov (United States)

    Alatawi, Abdullah; Beuvon, Frédéric; Grabar, Sophie; Leblanc, Sarah; Chaussade, Stanislas; Terris, Benoit; Barret, Maximilien

    2015-01-01

    Objectives Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) using standard needles has a high diagnostic value in the evaluation of solid pancreatic masses. Fenestrated needles have been developed to improve the quality of EUS-guided tissue sampling by providing core biopsies (FNB). Methods Patients with solid pancreatic masses of >2 cm were prospectively included in our study and randomized to receive EUS sampling, using either a standard 22G FNA or a 22G Procore® FNB needle. The main study endpoint was the number of needle passes required to obtain a diagnosis in more than 90% of cases. Results We included 100 patients (male = 63, female = 37; mean age = 68.4 years) in our study. We found that 88% of the lesions were malignant, with a mean size of 32 mm. A sample adequate for diagnosis was obtained in more than 90% of cases after the second needle pass in the FNB group, versus the third needle pass in the FNA group. Slide cellularity and presence of tissue microfragments were significantly higher in the FNB group. Sensitivity for the diagnosis of malignancy was 88.4% versus 97.8% for the EUS-FNA and EUS-FNB group, respectively, while specificity for both techniques was 100%. No complications were recorded. Conclusions Although the accuracy of both needle types for proving malignancy was similar, a lower number of passes was required with the FNB needles to achieve the same contributive sample rate as with the FNA needles. FNB also improved the histopathological quality of specimens, suggesting an overall superiority of FNB sampling. PMID:26279842

  7. Can We Predict Phyllodes Tumor among Fibroepithelial Lesions with Cellular Stroma Diagnosed at Breast Core Needle Biopsy?

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Hae Kyoung; Ko, Kyung Hee; Rho, Ji Young [Dept. of Radiology, CHA University College of Medicine, Seoul (Korea, Republic of); Moon, Hee Jung; Kim, Eun Kyung; Kim, Min Jung; Park, Byeong Woo [Dept. of Radiology, Yensei University College of Medicine, Seoul (Korea, Republic of)

    2011-06-15

    To evaluate the surgical outcomes of fibroepithelial lesion with cellular stroma (FELCS) diagnosed at sonography guided core needle biopsy of breast masses, and to determine whether the clinical and imaging features of this lesion could predict the presence of a phyllodes tumor. We retrospectively reviewed the pathologic results of sonography guided core needle biopsy of solid breast masses. A total of 55 FELCS diagnosed with this procedure that underwent subsequent surgical excision were included in this study; their medical records and radiologic images were retrospectively reviewed. The results of the surgical excision revealed 22 (40%) phyllodes tumors and 33 (60%) non-phyllodes tumors: 30 (54.6%) fibroadenomas, 1 (1.8%) adenosis, 1 (1.8%) fibrocystic changes and 1 (1.8%) fibroadenomatous hyperplasia. Lesion size and patient age were significantly different between phyllodes tumors and nonphyllodes tumors groups (32.2 {+-} 14.07 mm/22.4 {+-} 13.64 mm, p=0.0078, 43.5 {+-} 11.60 years/36.5 {+-} 10.25 years, p=0.0207). Among the sonographic features, only cleft was significantly more visible in phyllodes tumors than in non-phyllodes tumors (n=14 (70%)/n=6 (30%), p=0.0016). The size of the lesions, the age of the patients, and the sonographic features of cleft were the significant helpful variables to predict phyllodes tumors among FELCS diagnosed at breast core biopsy.

  8. Can We Predict Phyllodes Tumor among Fibroepithelial Lesions with Cellular Stroma Diagnosed at Breast Core Needle Biopsy?

    International Nuclear Information System (INIS)

    Jung, Hae Kyoung; Ko, Kyung Hee; Rho, Ji Young; Moon, Hee Jung; Kim, Eun Kyung; Kim, Min Jung; Park, Byeong Woo

    2011-01-01

    To evaluate the surgical outcomes of fibroepithelial lesion with cellular stroma (FELCS) diagnosed at sonography guided core needle biopsy of breast masses, and to determine whether the clinical and imaging features of this lesion could predict the presence of a phyllodes tumor. We retrospectively reviewed the pathologic results of sonography guided core needle biopsy of solid breast masses. A total of 55 FELCS diagnosed with this procedure that underwent subsequent surgical excision were included in this study; their medical records and radiologic images were retrospectively reviewed. The results of the surgical excision revealed 22 (40%) phyllodes tumors and 33 (60%) non-phyllodes tumors: 30 (54.6%) fibroadenomas, 1 (1.8%) adenosis, 1 (1.8%) fibrocystic changes and 1 (1.8%) fibroadenomatous hyperplasia. Lesion size and patient age were significantly different between phyllodes tumors and nonphyllodes tumors groups (32.2 ± 14.07 mm/22.4 ± 13.64 mm, p=0.0078, 43.5 ± 11.60 years/36.5 ± 10.25 years, p=0.0207). Among the sonographic features, only cleft was significantly more visible in phyllodes tumors than in non-phyllodes tumors (n=14 (70%)/n=6 (30%), p=0.0016). The size of the lesions, the age of the patients, and the sonographic features of cleft were the significant helpful variables to predict phyllodes tumors among FELCS diagnosed at breast core biopsy.

  9. MDCT-Guided Transthoracic Needle Aspiration Biopsy of the Lung Using the Transscapular Approach

    International Nuclear Information System (INIS)

    Rossi, Umberto G.; Seitun, Sara; Ferro, Carlo

    2011-01-01

    The purpose of this study is to report our preliminary experience using MDCT-guided percutaneous transthoracic needle aspiration biopsy using the transscapular approach in the upper posterolateral lung nodules, an area that it is difficult or hazardous to reach with the conventional approach. Five patients underwent CT-guided percutaneous transthoracic needle aspiration biopsy of the lung via the transscapular approach. A coaxial needle technique was used in all patients. Biopsy was successful in all patients. No major complications were encountered. One patient developed a minimal pneumothorax next to the lesion immediately after biopsy, which resolved spontaneously. MDCT-guided percutaneous transthoracic needle aspiration biopsy of the lung via the transscapular approach is an effective and safe procedure that reduces the risk of pneumothorax in selected patients.

  10. Predictors of underestimation of malignancy after image-guided core needle biopsy diagnosis of flat epithelial atypia or atypical ductal hyperplasia.

    Science.gov (United States)

    Yu, Chi-Chang; Ueng, Shir-Hwa; Cheung, Yun-Chung; Shen, Shih-Che; Kuo, Wen-Lin; Tsai, Hsiu-Pei; Lo, Yung-Feng; Chen, Shin-Cheh

    2015-01-01

    Flat epithelial atypia (FEA) and atypical ductal hyperplasia (ADH) are precursors of breast malignancy. Management of FEA or ADH after image-guided core needle biopsy (CNB) remains controversial. The aim of this study was to evaluate malignancy underestimation rates after FEA or ADH diagnosis using image-guided CNB and to identify clinical characteristics and imaging features associated with malignancy as well as identify cases with low underestimation rates that may be treatable by observation only. We retrospectively reviewed 2,875 consecutive image-guided CNBs recorded in an electronic data base from January 2010 to December 2011 and identified 128 (4.5%) FEA and 83 (2.9%) ADH diagnoses (211 total cases). Of these, 64 (30.3%) were echo-guided CNB procedures and 147 (69.7%) mammography-guided CNBs. Twenty patients (9.5%) were upgraded to malignancy. Multivariate analysis indicated that age (OR = 1.123, p = 0.002, increase of 1 year), mass-type lesion with calcifications (OR = 8.213, p = 0.006), and ADH in CNB specimens (OR = 8.071, p = 0.003) were independent predictors of underestimation. In univariate analysis of echo-guided CNB (n = 64), mass with calcifications had the highest underestimation rate (p < 0.001). Multivariate analysis of 147 mammography-guided CNBs revealed that age (OR = 1.122, p = 0.040, increase of 1 year) and calcification distribution were significant independent predictors of underestimation. No FEA case in which, complete calcification retrieval was recorded after CNB was upgraded to malignancy. Older age at diagnosis on image-guided CNB was a predictor of malignancy underestimation. Mass with calcifications was more likely to be associated with malignancy, and in cases presenting as calcifications only, segmental distribution or linear shapes were significantly associated with upgrading. Excision after FEA or ADH diagnosis by image-guided CNB is warranted except for FEA diagnosed using mammography-guided CNB with complete calcification

  11. Evaluation of a mammographic stereotactic device for localization, fine-needle aspiration cytologic studies, and core biopsy of suspicious lesions

    International Nuclear Information System (INIS)

    Fajardo, L.J.; Davey, G.A.

    1988-01-01

    Mammography-guided interventional breast procedures, such as preoperative localization, fine-needle aspiration cytology (FNAC), and core biopsy of suspicious lesions, require accurate three-dimensional localization. The authors have evaluated a prototype stereotactic mammography device for localizing abnormalities with both phantom and clinical studies. Twenty-six localizations on a phantom were within 0.5 mm +- 0.93 (standard deviation) from the lesions; accuracy in clinical procedures was within 0.6 mm +- 0.8. Procedures are performed an average of 8 minutes faster with this device. They are prospectively evaluating mammography-guided FNAC and core biopsy of suspicious lesions in 100 patients. Results of FNAC performed without the stereotactic device agreed with results of open surgical biopsy in six of eight patients; results of core biopsy agreed in seven of eight

  12. Novel needle guide reduces time to perform ultrasound-guided femoral nerve catheter placement: A randomised controlled trial.

    Science.gov (United States)

    Turan, Alparslan; Babazade, Rovnat; Elsharkawy, Hesham; Esa, Wael Ali Sakr; Maheshwari, Kamal; Farag, Ehab; Zimmerman, Nicole M; Soliman, Loran Mounir; Sessler, Daniel I

    2017-03-01

    Ultrasound-guided nerve blocks have become the standard when performing regional nerve blocks in anaesthesia. Infiniti Plus (CIVCO Medical Solutions, Kalona, Iowa, USA) is a needle guide that has been recently developed to help clinicians in performing ultrasound-guided nerve blocks. We tested the hypothesis that femoral nerve catheter placement carried out with the Infiniti Plus needle guide will be quicker to perform than without the Infiniti Plus. Secondary aims were to assess whether the Infiniti Plus needle guide decreased the number of block attempts and also whether it improved needle visibility. A randomised, controlled trial. Cleveland Clinic, Cleveland, Ohio, USA. We enrolled adult patients having elective total knee arthroplasty with a femoral nerve block and femoral nerve catheter. Patients, who were pregnant or those who had preexisting neuropathy involving the surgical limb, coagulopathy, infection at the block site or allergy to local anaesthetics were excluded. Patients were randomised into two groups to receive the ultrasound-guided femoral nerve catheter placement with or without the Infiniti Plus needle guide. The time taken to place the femoral nerve catheter, the number of attempts, the success rate and needle visibility were recorded. We used an overall α of 0.05 for both the primary and secondary analyses; the secondary analyses were Bonferroni corrected to control for multiple comparisons. The median (interquartile range Q1 to Q3) time to perform the femoral nerve catheter placement was 118 (100 to 150) s with Infiniti Plus and 177 (130 to 236) s without Infiniti Plus. Infiniti Plus significantly reduced the time spent performing femoral nerve catheterisation, with estimated ratio of means [(95% confidence interval), P value] of 0.67 [(0.60 to 0.75), P Infiniti Plus compared with no Infiniti Plus. However, Infiniti Plus had no effect on the odds of a successful femoral nerve catheter placement, number of attempts or percentage of perfect

  13. Initial experience with new dedicated needles for laparoscopic ultrasound-guided fine-needle aspiration and histological biopsies

    DEFF Research Database (Denmark)

    Mortensen, M B; Durup, J; Pless, T

    2001-01-01

    BACKGROUND AND STUDY AIMS: Laparoscopic ultrasonography (LUS) is an important imaging modality during laparoscopic staging of intra-abdominal malignancies, but LUS-assisted biopsy is often difficult or impossible. We report a newly developed inbuilt biopsy system for direct LUS-guided fine......-needle aspiration (FNA) and Tru-cut biopsies. PATIENTS AND METHODS: LUS-guided biopsy was performed in 20 patients with upper gastrointestinal tract tumors. The biopsied lesions had either not been previously detected by other imaging modalities or had been inaccessible, or the biopsy sample had been inadequate...... were good or acceptable in 18 patients (90%). Slight needle deviation (material was obtained, but pathological examination was impossible owing...

  14. Confocal Microscopy of Unfixed Breast Needle Core Biopsies: A Comparison to Fixed and Stained Sections

    Directory of Open Access Journals (Sweden)

    Zavislan James M

    2009-08-01

    Full Text Available Abstract Background Needle core biopsy, often in conjunction with ultrasonic or stereotactic guided techniques, is frequently used to diagnose breast carcinoma in women. Confocal scanning laser microscopy (CSLM is a technology that provides real-time digital images of tissues with cellular resolution. This paper reports the progress in developing techniques to rapidly screen needle core breast biopsy and surgical specimens at the point of care. CSLM requires minimal tissue processing and has the potential to reduce the time from excision to diagnosis. Following imaging, specimens can still be submitted for standard histopathological preparation. Methods Needle core breast specimens from 49 patients were imaged at the time of biopsy. These lesions had been characterized under the Breast Imaging Reporting And Data System (BI-RADS as category 3, 4 or 5. The core biopsies were imaged with the CSLM before fixation. Samples were treated with 5% citric acid and glycerin USP to enhance nuclear visibility in the reflectance confocal images. Immediately following imaging, the specimens were fixed in buffered formalin and submitted for histological processing and pathological diagnosis. CSLM images were then compared to the standard histology. Results The pathologic diagnoses by standard histology were 7 invasive ductal carcinomas, 2 invasive lobular carcinomas, 3 ductal carcinomas in-situ (CIS, 21 fibrocystic changes/proliferative conditions, 9 fibroadenomas, and 5 other/benign; two were excluded due to imaging difficulties. Morphologic and cellular features of benign and cancerous lesions were identified in the confocal images and were comparable to standard histologic sections of the same tissue. Conclusion CSLM is a technique with the potential to screen needle core biopsy specimens in real-time. The confocal images contained sufficient information to identify stromal reactions such as fibrosis and cellular proliferations such as intra-ductal and

  15. Confocal Microscopy of Unfixed Breast Needle Core Biopsies: A Comparison to Fixed and Stained Sections

    Science.gov (United States)

    2009-01-01

    Background Needle core biopsy, often in conjunction with ultrasonic or stereotactic guided techniques, is frequently used to diagnose breast carcinoma in women. Confocal scanning laser microscopy (CSLM) is a technology that provides real-time digital images of tissues with cellular resolution. This paper reports the progress in developing techniques to rapidly screen needle core breast biopsy and surgical specimens at the point of care. CSLM requires minimal tissue processing and has the potential to reduce the time from excision to diagnosis. Following imaging, specimens can still be submitted for standard histopathological preparation. Methods Needle core breast specimens from 49 patients were imaged at the time of biopsy. These lesions had been characterized under the Breast Imaging Reporting And Data System (BI-RADS) as category 3, 4 or 5. The core biopsies were imaged with the CSLM before fixation. Samples were treated with 5% citric acid and glycerin USP to enhance nuclear visibility in the reflectance confocal images. Immediately following imaging, the specimens were fixed in buffered formalin and submitted for histological processing and pathological diagnosis. CSLM images were then compared to the standard histology. Results The pathologic diagnoses by standard histology were 7 invasive ductal carcinomas, 2 invasive lobular carcinomas, 3 ductal carcinomas in-situ (CIS), 21 fibrocystic changes/proliferative conditions, 9 fibroadenomas, and 5 other/benign; two were excluded due to imaging difficulties. Morphologic and cellular features of benign and cancerous lesions were identified in the confocal images and were comparable to standard histologic sections of the same tissue. Conclusion CSLM is a technique with the potential to screen needle core biopsy specimens in real-time. The confocal images contained sufficient information to identify stromal reactions such as fibrosis and cellular proliferations such as intra-ductal and infiltrating carcinoma, and

  16. [Novel echogenic needle for ultrasound-guided peripheral nerve block "Hakko type CCR"].

    Science.gov (United States)

    Takayama, Wataru; Yasumura, Rie; Kaneko, Takehiko; Kobayashi, Yoshiro; Kamada, Takaaki; Yoshikawa, Tamotsu; Aoyama, Yasuhiko

    2009-04-01

    A novel echogenic insulated nerve block needle (CCR-needle: Echogenic Needle Type CCR; Hakko, Japan) is commercially available since 2006 in Japan. This needle has three echogenic dimples, namely corner cube reflectors (CCR) on its tip. The CCR-needle will potentially provide a significant advantage for detecting the needle tip. In this report, we firstly evaluated this new disposable echogenic needle in simulation phantom, and demonstrated improved visibility of the needle tip. Afterwards, an interscalene brachial plexus block was performed on a male patient undergoing shoulder surgery. The needle insertion procedure was the "out of plane" ultrasound-guided technique using simultaneous electrical nerve stimulation. The surgery was successfully conducted without any complications.

  17. EUS-Guided Needle-Based Confocal Laser Endomicroscopy

    DEFF Research Database (Denmark)

    Bhutani, Manoop S; Koduru, Pramoda; Joshi, Virendra

    2015-01-01

    Endoscopic ultrasound (EUS) has emerged as an excellent tool for imaging the gastrointestinal tract, as well as surrounding structures. EUS-guided fine-needle aspiration (EUS-FNA) has become the standard of care for the tissue sampling of a variety of masses and lymph nodes within and around...... the gut, providing further diagnostic and staging information. Confocal laser endomicroscopy (CLE) is a novel endoscopic method that enables imaging at a subcellular level of resolution during endoscopy, allowing up to 1000-fold magnification of tissue and providing an optical biopsy. A new procedure...... that has been developed in the past few years is needle-based confocal laser endomicroscopy (nCLE), which involves a mini-CLE probe that can be passed through a 1 9-gauge needle during EUS-FNA. This enables the real-time visualization of tissue at a microscopic level, with the potential to further improve...

  18. Comparison of Battery-Powered and Manual Bone Biopsy Systems for Core Needle Biopsy of Sclerotic Bone Lesions.

    Science.gov (United States)

    Cohen, Micah G; McMahon, Colm J; Kung, Justin W; Wu, Jim S

    2016-05-01

    The purpose of this study was to compare manual and battery-powered bone biopsy systems for diagnostic yield and procedural factors during core needle biopsy of sclerotic bone lesions. A total of 155 consecutive CT-guided core needle biopsies of sclerotic bone lesions were performed at one institution from January 2006 to November 2014. Before March 2012, lesions were biopsied with manual bone drill systems. After March 2012, most biopsies were performed with a battery-powered system and either noncoaxial or coaxial biopsy needles. Diagnostic yield, crush artifact, CT procedure time, procedure radiation dose, conscious sedation dose, and complications were compared between the manual and battery-powered core needle biopsy systems by Fisher exact test and t test. One-way ANOVA was used for subgroup analysis of the two battery-powered systems for procedure time and radiation dose. The diagnostic yield for all sclerotic lesions was 60.0% (93/155) and was significantly higher with the battery-powered system (73.0% [27/37]) than with the manual systems (55.9% [66/118]) (p = 0.047). There was no significant difference between the two systems in terms of crush artifact, procedure time, radiation dose, conscious sedation administered, or complications. In subgroup analysis, the coaxial battery-powered biopsies had shorter procedure times (p = 0.01) and lower radiation doses (p = 0.002) than the coaxial manual systems, but the noncoaxial battery-powered biopsies had longer average procedure times and higher radiation doses than the coaxial manual systems. In biopsy of sclerotic bone lesions, use of a battery-powered bone drill system improves diagnostic yield over use of a manual system.

  19. Incidence of tissue coring during transseptal catheterization when using electrocautery and a standard transseptal needle.

    Science.gov (United States)

    Greenstein, Eugene; Passman, Rod; Lin, Albert C; Knight, Bradley P

    2012-04-01

    The application of radiofrequency electrocautery to a standard, open-ended transseptal needle has been used to facilitate transseptal puncture (TSP). The purpose of this study was to determine the incidence of cardiac tissue coring when this technique is used. A model using excised swine hearts submerged in a saline-filled basin was developed to simulate TSP with electrocautery and a standard transseptal needle. Punctures were performed without the use of electrocautery and by delivering radiofrequency energy to the transseptal needle using a standard electrocautery pen at 3 target sites (fossa ovalis, non-fossa ovalis septum, and aorta). The tissue of the submerged heart was gently tented, and the needle was advanced on delivery of radiofrequency. The devices were retracted, and the needle was flushed in a collection basin. None of the TSPs without cautery caused tissue coring. For TSPs using electrocautery, the frequency of coring was at least 21% for any puncture permutation used in the study and averaged 37% at septal sites (Pelectrocautery and a standard open-ended Brockenbrough needle resulted in coring of the septal tissue in 35% of cases (33 of 96 punctures).

  20. Histopathologic Review of Previously Negative Prostatic Core Needle Biopsies following a New Diagnosis of Adenocarcinoma of the Prostate by Core Needle Biopsies: Implications for Quality Assurance Programs

    Directory of Open Access Journals (Sweden)

    Jay Patel

    2008-01-01

    Full Text Available Programs for quality assurance are increasingly important in surgical pathology. Many quality assurance (QA techniques for surgical pathology were adopted from procedures introduced in cytopathology. Surgical pathology specimens have diminished in size such that the majority of diagnostic biopsies of prostatic lesions are now core needle biopsies. These specimens raise issues similar to those of cytology specimens, including concerns regarding adequacy and the representative nature of the biopsy. Due to sample size, some neoplasms may not be diagnosed on initial biopsy, raising concerns regarding false negative results. Cytopathologists have instituted QA procedures including review of all previously negative slides received within five years prior to the new diagnosis of high grade squamous intraepithelial lesion or gynecologic malignancy. No such requirement exists in surgical pathology for review of core biopsies. The Department of Pathology at the University of Utah instituted a QA policy requiring review of prior negative prostatic needle biopsies following a new diagnosis of prostatic adenocarcinoma. We reviewed five years of QA records of prostate needle biopsy review. During this time, nine hundred and fifty-eight core biopsy sets were performed. Two hundred and ninety-five of these contained at least one biopsy with a diagnosis of adenocarcinoma. Two hundred and eight patients had a prior set of prostatic needle biopsies with a diagnosis of adenocarcinoma. The remaining 87 had prior biopsies with either a diagnosis of prostatic intraepithelial neoplasia (23, small atypical acinar proliferation (21 or no evidence of malignancy (43. QA review of these 87 cases revealed two biopsies which revealed foci of adenocarcinoma. Both had been initially diagnosed as no evidence of malignancy. The false negative rate for core biopsy was 0.68%. In an additional twenty-one cases, microscopic foci of atypical small acinar proliferations were found in

  1. Transjugular Core Liver Biopsy with a 19-Gauge Spring-Loaded Cutting Needle

    International Nuclear Information System (INIS)

    Choh, Jeffery; Dolmatch, Bart; Safadi, Rami; Long, Phil; Geisinger, Michael; Lammert, Gary; Dempsey, James

    1998-01-01

    One hundred and five sequential transjugular core liver biopsies (TJLBx) were performed in 101 patients with coagulopathy and/or ascites using the 19-gauge Quick-Core Biopsy (QCB) needle. Two-hundred and seventy-three cores were obtained in 295 passes (92.5%). One-hundred and two of the 105 procedures (97.1%) led to a histopathologic diagnosis. One of the three nondiagnostic biopsies was done because of severe autolysis of the liver. There was one subcapsular hematoma, one hepatic arteriovenous fistula, and one liver capsular puncture. Two minor neck hematomas occurred. One death was reported (unrelated to the procedure). QCB needle TJLBx is an effective and relatively safe way to obtain core liver samples

  2. CT-guided preoperative needle localization of MRI-detected breast lesions

    Energy Technology Data Exchange (ETDEWEB)

    Giagounidis, Elektra M. E-mail: giagounjdis@online.de; Markus, Ruwe; Josef, Luetzeler; Wemer, Audretsch; Mahdi, Rezai; Bernward, Kurtz

    2001-08-01

    To assess the value of accurate preoperative CT-guided needle localization of occult breast lesions, we reviewed a total of 39 needle-directed biopsies of breast tumors in 24 women. The average age was 52.9 years (range 31-67). All lesions were nonpalpable and mammographically, as well as sonographically occult. They were solely seen on MR-images. After demonstrating the suspicious region on CT scans, a hookwire was inserted. The correct position was confirmed by a control scan. The subsequent histopathological examination showed that 28 of the lesions (71.8%) were benign, among them mastopathy, fibrosis, fibroadenoma, papilloma, intramammary lymph node, liponecrosis and epitheliosis. Eleven lesions (28%) were malignant and showed either lobular, ductal or tubular cancer. Our results endorse that CT guided needle localization is a helpful method that allows a precise surgical excision of the suspect area with the removal of a minimal amount of breast tissue.

  3. Ultrasound-guided needle aspiration of parotid abscess

    Directory of Open Access Journals (Sweden)

    André Takahashi

    2012-01-01

    Full Text Available Ultrasound (US has been used as a tool for parotid abscess diagnosis and treatment. The present article aimed to report a case of 72-year-old woman with parotid abscess treated by US-guided needle aspiration and conventional surgical drainage. Along with the clinical report, indications, advantages, and limitations of the method are discussed.

  4. Incidental intraductal papillomas (breast diagnosed on needle core biopsy do not need to be excised.

    Science.gov (United States)

    Jaffer, Shabnam; Bleiweiss, Ira J; Nagi, Chandandeep

    2013-01-01

    Most authors recommend excision of intraductal papillomas diagnosed on core needle biopsy. This leads to the question of whether or not excision is necessary for incidental intraductal papillomas on core needle biopsy as opposed to those corresponding to imaging findings. Using the pathology computerized data base we retrospectively identified 46 incidental intraductal papillomas diagnosed on core needle biopsy from 1/2000 to 12/2008. Clinical, radiologic, and pathologic information was gathered and correlated. All core needle biopsies were reviewed to confirm the diagnosis of incidental intraductal papillomas, and excision specimens reviewed when available. Of the 46 patients, follow-up information was available in only 38. The age of the patients ranged from 39 to 82 years (mean = 48 years). Most incidental intraductal papillomas were diagnosed by mammotome core needle biopsy (36 cases). A total of 33 cases were performed for calcifications with the following indications: clustered = 21, new = 4, pleomorphic = 3, increasing = 3, indeterminant = 2. The correlating diagnoses included the following: fibrocystic changes with calcium phosphate = 18 or calcium oxalate = 10, fibroadenoma with calcifications = 5. The three masses were: two cases of cystic papillary apocrine metaplasia (I Ultrasound and 1 MRI) and 1 fibroadenoma (Ultrasound). In all cases, the intraductal papillomas were ≤0.2 cm, were not associated with calcifications, and were incidental to them or the underlying mass. A total of 14 patients underwent excision, whereas the remaining 24 have remained radiologically stable for over 12 months. The excision specimen findings were: fibrocystic changes = 8 and intraductal papilloma = 6. With the exception of one case, all the intraductal papilloma remained incidental to imaging findings. In this solitary case, the calcifications were described as pleomorphic and corresponded to fibrocystic changes calcifications on core needle

  5. The clinical application of percutaneous large core needle biopsy on large breast mass

    International Nuclear Information System (INIS)

    Peng Songhong; Ma Jie; Wang Guohong; Sun Guoping; Fu Jianmin; Zhou Dongxian

    2005-01-01

    Objective: An evaluation of the clinical application of percutaneous large core needle biopsy on large breast mass. Methods: Mammography and percutaneous large core needle biopsy were performed in 31 cases of large breast mass. Results: Apart from 5 cases showing characteristic calcification of malignancy, the rest cases were lack of diagnostic manifestation. Needle biopsy and pathological examination identified breast canner in 11 cases, suppurative mastitis in 9 case, fibrocystic mammary disorder in 7 cases, tuberculosis in 1 case, and fibroadenoma in 3 cases. Fibrocystic mammary disease was initially identified by biopsy in a case, while the following pathological diagnosis was fibrocystic mammary disorder with cancinoma in sim. Specificity rate of' biopsy was 96.8% and no false positive was observed. Vagotonia occurred in one case during the biopsy and hematoma in another. Conclusion: Percutaneous large core needle biopsy is a less invasive, simple, safe and reliable methods in the diagnosis of the large breast mass. And it may be recommended as a complementary procedure for routine imaging modality or surgical resection. (authors)

  6. Evaluation of The Value of Core Needle Biopsy in The Diagnosis of a Breast Mass

    Directory of Open Access Journals (Sweden)

    Asieh Sadat Fattahi

    2016-06-01

    Full Text Available Background: Core needle biopsy (CNB with histological findings is regarded as one of the most important diagnostic measures that make preoperative assessment and planning for appropriate treatment possible. The aim of this study was to determine the sensitivity and specificity of core biopsy results in our patients with benign and malignant breast lumps, especially for borderline breast lesions, by using a classification method.Methods: In this study, 116 patients who were referred to the Surgery Clinic of Ghaem Hospital, Mashhad University of Medical Sciences, Mashhad, Iran with breast lump and underwent diagnostic procedures such as mammography and ultrasound were selected. Core needle biopsy (Tru-cut #14 or 16 was performed. After that, excisional biopsy was done. The benign, malignant and unspecified samples obtained by core needle biopsy were evaluated with the samples of the surgical and pathological findings. Then, false positive, false negative, sensitivity, specificity, and diagnostic accuracy of the core needle biopsy method were calculated. Also, the National Health Service Breast Screening Program (NHSBSP classification was employed.Results: The mean age of the participants in this study was 39±13.13 years and the mean tumor size was 2.7 cm. An average of 3.35 biopsies was taken from all patients. Most of the pathology samples taken from CNB and excisional biopsy were compatible with invasive ductal carcinoma. Of the B type classifications, B5 was the most frequent in both methods. Borderline lesions B3 and B4 had a change in their category after surgery. About 2.5% of the samples in core biopsy were inadequate. Skin bruising was the most common core biopsy complication reported. While, the most common complication of excisional biopsy was hematoma. Accuracy, sensitivity, specificity, positive and negative predictive values of the core needle biopsy procedure compared with excisional biopsy was 95.5%, 92.6%, 100%, 100%, and 91

  7. CT-guided transthoracic cutting needle biopsy of intrathoracic lesions: Comparison between coaxial and single needle technique

    International Nuclear Information System (INIS)

    Wu, Reng-Hong; Tzeng, Wen-Sheng; Lee, Wei-Jing; Chang, Shih-Chin; Chen, Chia-Huei; Fung, Jui-Lung; Wang, Yen-Jen; Mak, Chee-Wai

    2012-01-01

    Purpose: To evaluate the complication rates and diagnostic accuracy of two different CT-guided transthoracic cutting needle biopsy techniques: coaxial method and single needle method. Methods: This study involved 198 consecutive subjects with 198 intrathoracic lesions. The first 98 consecutive subjects received a single needle cutting technique and the next 100 consecutive subjects received a coaxial technique. Both groups were compared in relation the diagnostic accuracy and complication rates. Results: No significant difference was found between the two groups concerning patient characteristics, lesions and procedure variables. There was a borderline statistical difference in the incidence of pneumothorax at within 24-h post biopsy between patients in the single needle group (5%) and the coaxial group (13%) (P = 0.053). Little difference was found in the pneumothorax rate at immediately post biopsy between the two groups, which was 28% in the single needle group and 31% in the coaxial group. There was no significant difference in the hemoptysis rate between the two groups, which was 9.2% in the single needle group and 11% in the coaxial group. Both techniques yielded an overall diagnostic accuracy of 98% for malignant lesions with similar sensitivity (single needle: 96.9% vs. coaxial: 96.4%) and specificity (single needle: 100% vs. coaxial: 100%). Conclusion: There is little difference in the pneumothorax rates and bleeding complications between patients who either received a single needle or a coaxial transthoracic cutting biopsy. Both techniques produce an overall diagnostic accuracy of 98% for malignant lesions.

  8. Technical Note: Error metrics for estimating the accuracy of needle/instrument placement during transperineal magnetic resonance/ultrasound-guided prostate interventions.

    Science.gov (United States)

    Bonmati, Ester; Hu, Yipeng; Villarini, Barbara; Rodell, Rachael; Martin, Paul; Han, Lianghao; Donaldson, Ian; Ahmed, Hashim U; Moore, Caroline M; Emberton, Mark; Barratt, Dean C

    2018-04-01

    Image-guided systems that fuse magnetic resonance imaging (MRI) with three-dimensional (3D) ultrasound (US) images for performing targeted prostate needle biopsy and minimally invasive treatments for prostate cancer are of increasing clinical interest. To date, a wide range of different accuracy estimation procedures and error metrics have been reported, which makes comparing the performance of different systems difficult. A set of nine measures are presented to assess the accuracy of MRI-US image registration, needle positioning, needle guidance, and overall system error, with the aim of providing a methodology for estimating the accuracy of instrument placement using a MR/US-guided transperineal approach. Using the SmartTarget fusion system, an MRI-US image alignment error was determined to be 2.0 ± 1.0 mm (mean ± SD), and an overall system instrument targeting error of 3.0 ± 1.2 mm. Three needle deployments for each target phantom lesion was found to result in a 100% lesion hit rate and a median predicted cancer core length of 5.2 mm. The application of a comprehensive, unbiased validation assessment for MR/US guided systems can provide useful information on system performance for quality assurance and system comparison. Furthermore, such an analysis can be helpful in identifying relationships between these errors, providing insight into the technical behavior of these systems. © 2018 American Association of Physicists in Medicine.

  9. Robotic Needle Guide for Prostate Brachytherapy: Clinical Testing of Feasibility and Performance

    Science.gov (United States)

    Song, Danny Y; Burdette, Everette C; Fiene, Jonathan; Armour, Elwood; Kronreif, Gernot; Deguet, Anton; Zhang, Zhe; Iordachita, Iulian; Fichtinger, Gabor; Kazanzides, Peter

    2010-01-01

    Purpose Optimization of prostate brachytherapy is constrained by tissue deflection of needles and fixed spacing of template holes. We developed and clinically tested a robotic guide towards the goal of allowing greater freedom of needle placement. Methods and Materials The robot consists of a small tubular needle guide attached to a robotically controlled arm. The apparatus is mounted and calibrated to operate in the same coordinate frame as a standard template. Translation in x and y directions over the perineum ±40mm are possible. Needle insertion is performed manually. Results Five patients were treated in an IRB-approved study. Confirmatory measurements of robotic movements for initial 3 patients using infrared tracking showed mean error of 0.489 mm (SD 0.328 mm). Fine adjustments in needle positioning were possible when tissue deflection was encountered; adjustments were performed in 54/179 (30.2%) needles placed, with 36/179 (20.1%) adjustments of > 2mm. Twenty-seven insertions were intentionally altered to positions between the standard template grid to improve the dosimetric plan or avoid structures such as pubic bone and blood vessels. Conclusions Robotic needle positioning provided a means of compensating for needle deflections as well as the ability to intentionally place needles into areas between the standard template holes. To our knowledge, these results represent the first clinical testing of such a system. Future work will be incorporation of direct control of the robot by the physician, adding software algorithms to help avoid robot collisions with the ultrasound, and testing the angulation capability in the clinical setting. PMID:20729152

  10. CT guided percutaneous needle biopsy of the chest: initial experience

    African Journals Online (AJOL)

    The objective of this article is to report our first experience of CT guided percutaneous thoracic biopsy and to demonstrate the accuracy and safety of this procedure. This was a retrospective study of 28 CT-Guided Percutaneous Needle Biopsies of the Chest performed on 24 patients between November 2014 and April 2015.

  11. MRI-guided prostate focal laser ablation therapy using a mechatronic needle guidance system

    Science.gov (United States)

    Cepek, Jeremy; Lindner, Uri; Ghai, Sangeet; Davidson, Sean R. H.; Trachtenberg, John; Fenster, Aaron

    2014-03-01

    Focal therapy of localized prostate cancer is receiving increased attention due to its potential for providing effective cancer control in select patients with minimal treatment-related side effects. Magnetic resonance imaging (MRI)-guided focal laser ablation (FLA) therapy is an attractive modality for such an approach. In FLA therapy, accurate placement of laser fibers is critical to ensuring that the full target volume is ablated. In practice, error in needle placement is invariably present due to pre- to intra-procedure image registration error, needle deflection, prostate motion, and variability in interventionalist skill. In addition, some of these sources of error are difficult to control, since the available workspace and patient positions are restricted within a clinical MRI bore. In an attempt to take full advantage of the utility of intraprocedure MRI, while minimizing error in needle placement, we developed an MRI-compatible mechatronic system for guiding needles to the prostate for FLA therapy. The system has been used to place interstitial catheters for MRI-guided FLA therapy in eight subjects in an ongoing Phase I/II clinical trial. Data from these cases has provided quantification of the level of uncertainty in needle placement error. To relate needle placement error to clinical outcome, we developed a model for predicting the probability of achieving complete focal target ablation for a family of parameterized treatment plans. Results from this work have enabled the specification of evidence-based selection criteria for the maximum target size that can be confidently ablated using this technique, and quantify the benefit that may be gained with improvements in needle placement accuracy.

  12. Ultrasound guided percutaneous fine needle aspiration biopsy of the liver with focal lesion

    International Nuclear Information System (INIS)

    Ko, Gang Seok; Yang, Hyun Cheol; Park, Byoung Lan; Kim, Byoung Geun; Sohn, Jang Sihn

    1985-01-01

    The ultrasound-guided fine needle aspirations were performed in order to diagnose a suspected neoplastic or infectious disease in 52 patients with focal liver disease. Of these, neoplastic lesions were suspected in 31 patients and infectious lesions in 21 patients ultrasonically and/or clinically. The overall accuracy for both suspected malignant and infectious disease was 79% (41/52). The primary indication for fine needle aspiration was to document the presence of malignancy and to avoid a diagnostic laparotomy, and to drain hepatic abscess. Consequently we were convinced that the ultrasound-guided percutaneous fine needle aspiration biopsy in the focal liver disease is the best method for a conclusive diagnosis

  13. Breast lesions with imaging-histologic discordance during US-guided 14G automated core biopsy: can the directional vacuum-assisted removal replace the surgical excision? Initial findings

    International Nuclear Information System (INIS)

    Kim, Min Jung; Kim, Eun-Kyung; Lee, Ji Young; Youk, Ji Hyun; Oh, Ki Keun; Park, Byeong-Woo; Kim, Seung-Il; Kim, Haeryoung

    2007-01-01

    The purpose of this study was to determine the frequency of carcinoma at percutaneous directional vacuum-assisted removal (DVAR) in women with imaging-histologic discordance during ultrasound (US)-guided automated core needle biopsy, and to determine the role of DVAR in breast lesions with imaging-histologic discordance. A US-guided 14-gauge automated core needle biopsy was performed on 837 consecutive lesions. Imaging-histologic discordance was prospectively considered in 33 of 634 benign biopsies. DVAR was recommended in those lesions. Among the 33 lesions, 26 lesions that underwent subsequent DVAR or surgical excision made up our study population. Medical records, imaging studies, and histologic findings were reviewed. Among the 26 lesions, 18 lesions underwent subsequent US-guided DVAR, with 8-gauge probes for 15 of the lesions, and 11-gauge for three of the lesions. Two lesions were diagnosed as having carcinoma (2/18, 11.1% of upgrade rate; 3.1-32.8% CI). The remaining eight lesions underwent subsequent surgical excision, and carcinoma was diagnosed in one case (12.5% of upgrade rate; 2.2-47.1% CI). A US-guided DVAR of the breast mass with imaging-histologic discordance during US-guided 14-gauge automated core needle biopsy is a valuable alternative to surgery as a means of obtaining a definitive histological diagnosis. (orig.)

  14. Contrast-Enhanced Ultrasound Improves the Pathological Outcomes of US-Guided Core Needle Biopsy That Targets the Viable Area of Anterior Mediastinal Masses

    Directory of Open Access Journals (Sweden)

    Jian-hua Zhou

    2018-01-01

    Full Text Available Based on the option that ultrasound-guided core needle biopsy (US-CNB of the enhanced portion of anterior mediastinal masses (AMMs identified by contrast-enhanced ultrasound (CEUS would harvest viable tissue and benefit the histological diagnoses, a retrospective study was performed to elucidate the correlation between the prebiopsy CEUS and diagnostic yield of AMMs and found that CEUS potentially improved the diagnostic yield of AMMs compared with conventional US with a significant increase in the cellularity of samples. Furthermore, the marginal blood flow signals and absence of necrosis can predict the diagnostic yield of AMM. It was concluded that US-CNB of the viable part of AMMs, as verified by CEUS, was able to harvest sufficient tissue with more cellularity that could be used for ancillary studies and improve the diagnostic yield. And CEUS was recommended to those patients with AMMs undergoing repeated US-CNB, with the absence of marginal blood signals or presence of necrosis.

  15. False-negative results of breast core needle biopsies - retrospective analysis of 988 biopsies

    International Nuclear Information System (INIS)

    Boba, M.; Koltun, U.; Bobek-Billewicz, B.; Eksner, B.; Olejnik, T.; Chmielik, E.

    2011-01-01

    Background: Breast cancer is the most common malignant neoplasm and the most common cause of death among women. The core needle biopsy is becoming a universal practice in diagnosing breast lesions suspected of malignancy. Unfortunately, breast core needle biopsies also bear the risk of having false-negative results. Material/Methods: 988 core needle breast biopsies were performed at the Maria Sklodowska-Curie Memorial Cancer Center and Institute of Oncology, Gliwice Branch, between 01 March 2006 and 29 February 2008. Malignant lesions were diagnosed in 426/988 (43.12%) cases, atypical hyperplasia in 69/988 (6.98%), and benign lesions in 493/988 (49.90%) cases. Results: Twenty-two out of 988 biopsies (2.23%) were found to be false negative. Histopathological assessment of tissue specimens was repeated in these cases. In 14/22 (64%) cases, the previous diagnosis of a benign lesion was changed. In 8/22 (36%) cases, the diagnosis of a benign lesion was confirmed. False-negative rate was calculated at 2.2%. The rate of false-negative diagnoses resulting from a radiological mistake was estimated at 36%. The rate of false-negative diagnoses, resulting from histopathological assessment, was 64%. False-negative results caused by a radiological error comprised 1.5% of all histopathologically diagnosed cancers and atypias (sensitivity of 98.5%). There were no false-positive results in our material - the specificity of the method was 100%. Conclusions: Histopathological interpretation is a substantial cause of false-negative results of breast core needle biopsy. Thus, in case of a radiological-histopathological divergence, histopathological analysis of biopsy specimens should be repeated. The main radiological causes of false-negative results of breast core needle biopsy are as follows: sampling from an inappropriate site and histopathological non-homogeneity of cancer infiltration. (authors)

  16. Usefulness of sono-guided needle puncture for MR arthrography of the shoulder

    International Nuclear Information System (INIS)

    Choi, Jae Woong; Hong, Suk Ju; Suh, San Il; Yong, Hwan Suk; Kim, Jung Hyuk; Park, Cheol Min; Suh, Won Hyuck; Kim, Myung Gyu

    2000-01-01

    To evaluate the usefulness of sono-guided needle puncture for MR arthrography of the shoulder to locate the path of access and to control the correct placement of the needle into the shoulder. Fifteen patients with suspicion of shoulder pathology were included in this study. Patients were laid in supine positions with the arm extended and slightly abducted, the palm of the hand facing upward. A sonographic unit with a high resolution transducer with 7.5 MHz linear array was used. Axial images in the anterior aspect of the shoulder were obtained to localize the coracoid process and the anteromedical portion of the humerus. Using an aseptic technique, a 21-guage needle was advanced into the shoulder joint under ultrasonographic guidance. When the needle made contract with the articular cartilage of the humeral head, the needle was tiled to position is point in the articular cavity. Solution of 0.1 ml gadopentetate dimeglumine in 25 ml of normal saline was prepared and 12-16 ml was injected into the joint cavity. The intra-articular position of the needle and the compete distension of the shoulder joint were again confirmed by sonography. The needle was accurately placed in 14 out of 15 patients without damage to neighboring structures. It took 10 to 15 minutes to complete the procedure in 14 patients. No side effects attributable to gadopentetate dimeglumine were found. Sono-guided needle puncture for the shoulder MR arthrography can be a substitutable method for fluoroscopic guidance, with easy access, advantages of lacking radiation hazard and eliminating the need for iodized contrast agents.

  17. Sonographically guided fine-needle biopsy of thyroid nodules: the effects of nodule characteristics, sampling technique, and needle size on the adequacy of cytological material

    International Nuclear Information System (INIS)

    Degirmenci, B.; Haktanir, A.; Albayrak, R.; Acar, M.; Sahin, D.A.; Sahin, O.; Yucel, A.; Caliskan, G.

    2007-01-01

    Aim: To evaluate the effects of sonographic characteristics of thyroid nodules, the diameter of needle used for sampling, and sampling technique on obtaining sufficient cytological material (SCM). Materials and methods: We performed sonography-guided fine-needle biopsy (FNB) in 232 solid thyroid nodules. Size-, echogenicity, vascularity, and localization of all nodules were evaluated by Doppler sonography before the biopsy. Needles of size 20, 22, and 24 G were used for biopsy. The biopsy specimen was acquired using two different methods after localisation. In first method, the needle tip was advanced into the nodule in various positions using a to-and-fro motion whilst in the nodule, along with concurrent aspiration. In the second method, the needle was advanced vigorously using a to-and-fro motion within the nodule whilst being rotated on its axis (capillary-action technique). Results: The mean nodule size was 2.1 ± 1.3 cm (range 0.4-7.2 cm). SCM was acquired from 154 (66.4%) nodules by sonography-guided FNB. In 78 (33.6%) nodules, SCM could not be collected. There was no significant difference between nodules with different echogenicity and vascularity for SCM. Regarding the needle size, the lowest rate of SCM was obtained using 20 G needles (56.6%) and the highest rate of adequate material was obtained using 24 G needles (82.5%; p = 0.001). The SCM rate was 76.9% with the capillary-action technique versus 49.4% with the aspiration technique (p < 0.001). Conclusion: Selecting finer needles (24-25 G) for sonography-guided FNB of thyroid nodules and using the capillary-action technique decreased the rate of inadequate material in cytological examination

  18. VALIDITY OF CORE NEEDLE BIOPSY IN THE HISTOPATHOLOGICAL VERIFICATION OF PAROTID GLAND LESIONS

    Directory of Open Access Journals (Sweden)

    Oroz Aleksandar

    2016-07-01

    Full Text Available Background and purpose: An adequate diagnosis of a parotid gland enlargement is crucial for an appropriate treatment. The aim of the study was to evaluate effectiveness and minimal invasiveness of diagnostic procedures of core-needle biopsy. Materials and Methods: This study involved 67 patients, aged 40 to 90 years, with a tumor mass in the submandibular and parotid region. Method used for taking samples of pathological masses was BD Disposable guillotine spring-loaded needle for biopsies on soft tissues. Final diagnoses were established on the basis of surgical-pathological results in 67 cases, and on the basis of histopathological analysis of core-biopsy samples. Results: Compared with results of surgical biopsy, core-needle biopsy had sensitivity of 100% in differentiating benign from malignant lesions and in setting up an adequate diagnosis. Its positive predictive values were 100% in diagnosing malignancy. There were found 28 non-malignant and 39 malignant lesions with fewer disadvantages for patients.

  19. Fiber Bragg gratings-based sensing for real-time needle tracking during MR-guided brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Borot de Battisti, Maxence, E-mail: M.E.P.Borot@umcutrecht.nl; Maenhout, Metha; Lagendijk, Jan J. W.; Vulpen, Marco van; Moerland, Marinus A. [Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, Utrecht 3584 CX (Netherlands); Denis de Senneville, Baudouin [Imaging Division, University Medical Center Utrecht, Heidelberglaan 100, Utrecht 3584 CX, The Netherlands and IMB, UMR 5251 CNRS/University of Bordeaux, Talence 33400 (France); Hautvast, Gilion; Binnekamp, Dirk [Philips Group Innovation Biomedical Systems, Eindhoven 5656 AE (Netherlands)

    2016-10-15

    Purpose: The development of MR-guided high dose rate (HDR) brachytherapy is under investigation due to the excellent tumor and organs at risk visualization of MRI. However, MR-based localization of needles (including catheters or tubes) has inherently a low update rate and the required image interpretation can be hampered by signal voids arising from blood vessels or calcifications limiting the precision of the needle guidance and reconstruction. In this paper, a new needle tracking prototype is investigated using fiber Bragg gratings (FBG)-based sensing: this prototype involves a MR-compatible stylet composed of three optic fibers with nine sets of embedded FBG sensors each. This stylet can be inserted into brachytherapy needles and allows a fast measurement of the needle deflection. This study aims to assess the potential of FBG-based sensing for real-time needle (including catheter or tube) tracking during MR-guided intervention. Methods: First, the MR compatibility of FBG-based sensing and its accuracy was evaluated. Different known needle deflections were measured using FBG-based sensing during simultaneous MR-imaging. Then, a needle tracking procedure using FBG-based sensing was proposed. This procedure involved a MR-based calibration of the FBG-based system performed prior to the interventional procedure. The needle tracking system was assessed in an experiment with a moving phantom during MR imaging. The FBG-based system was quantified by comparing the gold-standard shapes, the shape manually segmented on MRI and the FBG-based measurements. Results: The evaluation of the MR compatibility of FBG-based sensing and its accuracy shows that the needle deflection could be measured with an accuracy of 0.27 mm on average. Besides, the FBG-based measurements were comparable to the uncertainty of MR-based measurements estimated at half the voxel size in the MR image. Finally, the mean(standard deviation) Euclidean distance between MR- and FBG-based needle position

  20. Ultrasound guided needle biopsy of skeletal muscle in neuromuscular disease

    DEFF Research Database (Denmark)

    Lindequist, S; Schrøder, H D; Larsen, C

    1990-01-01

    Guided by ultrasonography percutaneous needle biopsy of skeletal muscle was performed in 24 patients, using the one hand held Biopty system and a 2 mm Tru-Cut needle. The specimens were graded with regard to diagnostic quality and utility and almost all specimens (96%) were of highest quality. Th....... The use of ultrasonography was helpful in selecting a suitable area for the biopsy and vascular structures could be avoided. The procedure was well tolerated and easy to perform, and no complications were recorded....

  1. Scan-guided fine needle aspiration biopsy in malignant hepatic disease

    International Nuclear Information System (INIS)

    Johansen, P.; Svendsen, K.N.

    1978-01-01

    The method of scan-guided fine needle aspiration biopsy of the liver is described, and the diagnostic value of this combined method in the diagnosis of malignant hepatic disease is evaluated in 83 confirmed cases, showing a specificity of 100% and a sensitivity of 94%. The combined method is compared to liver scanning alone and to Menghini biopsy. Different methods for the diagnosis of malignant hepatic disease are discussed, and it is concluded that scan-guided fine needle aspiration biopsy has a diagnostic value only obtainable otherwise by a combination of liver scanning and biopsy during laparoscopy. Cytologic features in the two most common tumor types in this study, i.e., metastatic colonic adenocarcinoma and hepatocarcinoma, are presented along with a brief discussion of the specificity of the cytologic diagnosis of hepatocarcinoma

  2. CT-guided spinal injection: initial experience with Sprotte tip needles

    Energy Technology Data Exchange (ETDEWEB)

    Pua, Uei [Tan Tock Seng Hospital, Department of Diagnostic Radiology, Singapore (Singapore)

    2010-09-15

    The purpose of this paper is to describe our initial experience and to illustrate the potential benefits of using small caliber (25 and 27 G), noncutting pencil point needles (Sprotte) with single puncture coaxial technique in CT-guided spinal intervention (CTSI). From January 2009 to June 2009, Sprotte needles with single puncture coaxial technique were used in a total of ten patients for selective nerve root block (SNRB), facet joint block, and pars block under CT fluoroscopy (total of 16 target structures). All procedures were performed without conscious sedation, and visual analog scale (VAS) scores were recorded to determine pain related to needle placement. Total CT fluoroscopy time and out-of-plane needle deviation were obtained. Final needle position was documented by contrast injection for SNRBs and image capture for joint space cannulation. Sixteen out of the 16 structures were successfully targeted. No increase in VAS scores associated with needle placement was recorded, after infiltration of local anesthesia. Optimal peri-neurograms were obtained in all cases of SNRB, despite the side-hole opening in the Sprotte needles. Mean CT fluoroscopy time was 2 s (range 2-8 s per structure), and there was no case of out-of-plane needle deviation that required adjustment of the CT gantry. The use of small caliber Sprotte needles in CTSI is technically feasible and represents a potential refinement to current techniques in the management of chronic spinal pain. (orig.)

  3. Acupuncture sensation during ultrasound guided acupuncture needling

    Science.gov (United States)

    Park, Jongbae J.; Akazawa, Margeaux; Ahn, Jaeki; Beckman-Harned, Selena; Lin, Feng-Chang; Lee, Kwangjae; Fine, Jason; Davis, Robert T; Langevin, Helene

    2014-01-01

    Background Although acupuncture sensation (also known as de qi) is a cornerstone of traditional acupuncture therapy, most research has accepted the traditional method of defining acupuncture sensation only through subjective patient reports rather than on any quantifiable physiological basis. Purpose To preliminarily investigate the frequency of key sensations experienced while needling to specific, quantifiable tissue levels (TLs) guided by ultrasound (US) imaging. Methods Five participants received needling at two acupuncture points and two control points at four TLs. US scans were used to determine when each TL was reached. Each volunteer completed 32 sets of modified Southampton Needle Sensation Questionnaires. Part one of the study tested sensations experienced at each TL and part two compared the effect of oscillation alone versus oscillation + rotation. Results In all volunteers, the frequency of pricking, sharp sensations was significantly greater in shallower TLs than deeper (p=0.007); the frequency of sensations described as deep, dull and heavy, as spreading, and as electric shocks was significantly greater in deeper TLs than shallower (p=0.002). Sensations experienced did not significantly differ between real and control points within each of three TLs (p>0.05) except TL 4 (p=0.006). The introduction of needle rotation significantly increased deep, dull, heavy sensations, but not pricking and sharp sensations; within each level, the spectrum of sensation experienced during both oscillation + rotation and oscillation alone did not significantly differ between acupuncture and control points. Conclusion The preliminary study indicates a strong connection between acupuncture sensation and both tissue depth and needle rotation. Furthermore, the new methodology has been proven feasible. A further study with an objective measurement is warranted. PMID:21642648

  4. Fine-needle versus core-needle biopsy – which one to choose in preoperative assessment of focal lesions in the breasts? Literature review

    Directory of Open Access Journals (Sweden)

    Ewa Łukasiewicz

    2017-12-01

    Full Text Available Aim: The aim of the study was to review two techniques that can be used to verify focal lesions in the breasts: fine-needle aspiration biopsy and core-needle biopsy. Material and methods: Fifty-five articles (original papers and reviews, half of them published within the past 5 years, were included in the analysis. The authors also took their own experience into account. Results: Pre-operative assessment of focal lesions in the breasts is crucial in the planning of further therapeutic management. The role of fine-needle aspiration biopsy has been reduced lately due to its low sensitivity and specificity as well as a high rate of non-diagnostic, suspicious and false negative results. This method does not enable one to differentiate between in situ and invasive disease. Currently, fine-needle biopsy is recommended for cystic lesions, suspected of being recurrences in the chest wall, and lymph node metastases. Core-needle biopsy is the basic diagnostic method of breast lesions. According to the recommendations of the Polish Ultrasound Society and American College of Radiology, BIRADS 4 and 5 lesions should be evaluated histopathologically. Core-needle biopsy makes it possible to establish a final diagnosis more frequently than fine-needle biopsy, both in the case of benign and malignant lesions. It delivers more information about the nature of a tumor (mutation of HER-2, estrogen and progesterone receptors and Ki-67 index. Its limitations include: underestimation of invasion and failure to recognize the components of ductal carcinoma in situ in papillary and atypical lesions. Single fine-needle aspiration biopsy is inexpensive, but when considering the cost of further diagnosis due to non-diagnostic, suspicious and atypical results, this method generates high additional costs. Conclusions: Microscopic verification of focal breast lesions is crucial for further therapeutic decisions. It has been proven that histopathological verification is more

  5. Improving needle tip identification during ultrasound-guided procedures in anaesthetic practice.

    Science.gov (United States)

    Scholten, H J; Pourtaherian, A; Mihajlovic, N; Korsten, H H M; A Bouwman, R

    2017-07-01

    Ultrasound guidance is becoming standard practice for needle-based interventions in anaesthetic practice, such as vascular access and peripheral nerve blocks. However, difficulties in aligning the needle and the transducer can lead to incorrect identification of the needle tip, possibly damaging structures not visible on the ultrasound screen. Additional techniques specifically developed to aid alignment of needle and probe or identification of the needle tip are now available. In this scoping review, advantages and limitations of the following categories of those solutions are presented: needle guides; alterations to needle or needle tip; three- and four-dimensional ultrasound; magnetism, electromagnetic or GPS systems; optical tracking; augmented (virtual) reality; robotic assistance; and automated (computerised) needle detection. Most evidence originates from phantom studies, case reports and series, with few randomised clinical trials. Improved first-pass success and reduced performance time are the most frequently cited benefits, whereas the need for additional and often expensive hardware is the greatest limitation to widespread adoption. Novice ultrasound users seem to benefit most and great potential lies in education. Future research should focus on reporting relevant clinical parameters to learn which technique will benefit patients most in terms of success and safety. © 2017 The Association of Anaesthetists of Great Britain and Ireland.

  6. Learning Ultrasound-Guided Needle Insertion Skills through an Edutainment Game

    Science.gov (United States)

    Chan, Wing-Yin; Ni, Dong; Pang, Wai-Man; Qin, Jing; Chui, Yim-Pan; Yu, Simon Chun-Ho; Heng, Pheng-Ann

    Ultrasound-guided needle insertion is essential in many of minimally invasive surgeries or procedures, such as biopsy, drug delivery, spinal anaesthesia, etc. Accurate and safe needle insertion is a difficult task due to the high requirement of hand-eye coordination skills. Many proposed virtual reality (VR) based training systems put their emphasis on realistic simulation instead of pedagogical efficiency. The lack of schematic training scenario leads to boredom of repetitive operations. To solve this, we present our novel training system with the integration of game elements in order to retain the trainees' enthusiasm. Task-oriented scenarios, time attack scenarios and performance evaluation are introduced. Besides, some state-of-art technologies are also presented, including ultrasound simulation, needle haptic rendering as well as a mass-spring-based needle-tissue interaction simulation. These works are shown to be effective to keep the trainees up with learning.

  7. Biópsia com agulha grossa guiada por ultrassonografia para o diagnóstico dos tumores fibroepiteliais da mama Ultrasound-guided core needle biopsy for the diagnosis of fibroepithelial breast tumors

    Directory of Open Access Journals (Sweden)

    Marcos Desidério Ricci

    2011-01-01

    Full Text Available OBJETIVO: avaliar a taxa de concordância da biópsia percutânea com agulha grossa guiada por ultrassom seguida pela biópsia excisional em nódulos de mama palpáveis, sugestivos de tumores fibroepiteliais. MÉTODO: estudo retrospectivo que selecionou 70 biópsias com diagnóstico histológico de tumor fibroepitelial em 67 dentre 531 pacientes com lesões mamárias submetidas à biópsia percutânea com agulha grossa guiada por ultrassonografia, com transdutor linear de alta frequência (7.5 MHz, utilizando pistola automática Bard-Magnum e agulha 14 gauge. Foram incluídos os casos com diagnóstico de tumor fibroepitelial na biópsia percutânea ou biópsia excisional. Biópsias com diagnóstico histopatológico de fibroesclerose também foram incluídas no estudo. A força da concordância entre o resultado da biópsia percutânea e da biópsia excisional foi medida pelo coeficiente de Kappa. RESULTADOS: a biópsia excisional revelou 40 casos de fibroadenoma (57,1%, 19 de tumor filoide (27,2% e 11 de fibroesclerose (15,7%. A taxa de concordância para o fibroadenoma foi substancial (k = 0,68; IC95% = 0,45 - 0,91, quase perfeita para o tumor filoide (k = 0,81; IC95% = 0,57 - 1,0 e moderada para a fibroesclerose (k = 0,58; IC95% = 0,36 - 0,90. CONCLUSÕES: a biópsia percutânea com agulha grossa é propedêutica minimamente invasiva que tem taxas de concordância com a biópsia excisional, de "substancial" a "quase perfeita". A fibroesclerose deve ser considerada no diagnóstico diferencial dos tumores fibroepiteliais.PURPOSE: to evaluate the concordance rate of ultrasound-guided core needle biopsy followed by excisional biopsy in palpable breast lumps, suggestive of fibroepithelial tumors. METHOD: a retrospective study included 70 biopsies with a histological diagnosis of fibroepithelial tumor in 67 out of 531 patients with breast lesions submitted to ultrasound-guided core needle biopsy with a high frequency (7.5 MHz linear transducer

  8. False-negative results of breast core needle biopsies – retrospective analysis of 988 biopsies

    International Nuclear Information System (INIS)

    Boba, Marek; Kołtun, Urszula; Bobek-Billewicz, Barbara; Chmielik, Ewa; Eksner, Bartosz; Olejnik, Tomasz

    2011-01-01

    Breast cancer is the most common malignant neoplasm and the most common cause of death among women. The core needle biopsy is becoming a universal practice in diagnosing breast lesions suspected of malignancy. Unfortunately, breast core needle biopsies also bear the risk of having false-negative results. 988 core needle breast biopsies were performed at the Maria Skłodowska-Curie Memorial Cancer Center and Institute of Oncology, Gliwice Branch, between 01 March 2006 and 29 February 2008. Malignant lesions were diagnosed in 426/988 (43.12%) cases, atypical hyperplasia in 69/988 (6.98%), and benign lesions in 493/988 (49.90%) cases. Twenty-two out of 988 biopsies (2.23%) were found to be false negative. Histopathological assessment of tissue specimens was repeated in these cases. In 14/22 (64%) cases, the previous diagnosis of a benign lesion was changed. In 8/22 (36%) cases, the diagnosis of a benign lesion was confirmed. False-negative rate was calculated at 2.2%. The rate of false-negative diagnoses resulting from a radiological mistake was estimated at 36%. The rate of false-negative diagnoses, resulting from histopathological assessment, was 64%. False-negative results caused by a radiological error comprised 1.5% of all histopathologically diagnosed cancers and atypias (sensitivity of 98.5%). There were no false-positive results in our material - the specificity of the method was 100%. Histopathological interpretation is a substantial cause of false-negative results of breast core needle biopsy. Thus, in case of a radiological-histopathological divergence, histopathological analysis of biopsy specimens should be repeated. The main radiological causes of false-negative results of breast core needle biopsy are as follows: sampling from an inappropriate site and histopathological non-homogeneity of cancer infiltration

  9. Computed tomography - guided cutting needle biopsy of pulmonary lesions

    International Nuclear Information System (INIS)

    Liao Shin Yu; Deheinzelin, Daniel; Younes, Riad N.; Chojniak, Rubens

    2002-01-01

    The purpose of this study was to report the experience of a radiology department in the use of computed tomography-guided cutting needle biopsy of pulmonary nodules, by evaluating diagnostic yield and incidence of complications. This is a retrospective analysis of 52 consecutive patients who underwent lung lesion biopsy guided by computed tomography, performed between May 1997 and May 2000. Thirty-five patients were male and 17 were female, with ages ranging from 5 to 85 years (median, 62 years). The size of the lesions ranged from 1.8 to 15 cm (median, 5.4 cm). In a total of 52 biopsies of lung lesions, 51 biopsies (98.1%) supplied appropriate material for histopathological diagnosis, with 9 diagnosed (17.3%) as benign and 42 (80.8%) as malignant lesions. Specific diagnosis was obtained in 44 (84.6%) biopsies: 4 benign (9.1%) and 40 (90.9%) malignant lesions. The sensitivity, specificity, and accuracy of the cutting needle biopsies for determining presence of malignancy were 96.8%, 100%, and 97.2%, respectively. Complications occurred in 9 cases (17.3%), including 6 cases (11.5%) of small pneumothorax, 1 (1.9%) of hemoptysis, 1 (1.9%) of pulmonary hematoma, and 1 (1.9%) of thoracic wall hematoma. All had spontaneous resolution. There were no complications requiring subsequent intervention. The high sensitivity and specificity of the method and the low rate of complications have established cutting needle biopsy as an efficient and safe tool for the diagnosis of lung lesions. In our hospital, cutting needle biopsy is considered a reliable procedure for the evaluation of indeterminate pulmonary nodules. (author)

  10. Examining the sensitivity of ultrasound-guided large core biopsy for invasive breast carcinoma in a population screening programme

    International Nuclear Information System (INIS)

    Rouse, Hannah C.; Ussher, Simon; Cawson, Jennifer N.; Kavanagh, Anne M.

    2013-01-01

    To evaluate the sensitivity of ultrasound-guided core-needle biopsy (UCB) in invasive breast carcinoma and to establish causes of false-negative biopsy in a population screening programme. We identified 571 consecutive women diagnosed with surgically proven invasive breast cancer. Histology from 14-gauge UCB was compared with surgical histology to identify true-positive and false-negative ultrasound core biopsies. True-positive and false-negative groups were compared for tumour size and histology. On blinded review of UCB images and pathology reports from false negative (n=20) and a random sample of true-positive cases (n=80), we compared core sample number and needle visualisation in the lesion. Of 571 carcinomas sampled with UCB, 551 (96.5%) were true positive and 20 (3.5%) were false negative. The mean core number was 2.0 (range 1–3) for false negatives and 2.25 (range 1–4) for true positives (P=0.27). Mean tumour sizes were 13.3 and 16.2mm for the false-negative and true-positive groups, respectively (P=0.25). Tubular carcinomas represented 30% (6/20) of false-negative cases compared with 5.1% (28/551) of the true-positive cases (P<0.001). On blinded review, needle visualisation within the lesion was demonstrated in 47.4% (9/19) of false-negative cases and 76.3% (61/80) of true-positive cases (P=0.02).We demonstrated a sensitivity of 96.5% with a mean of 2.21 cores. False-negative results were more likely in the absence of post-fire needle position verification and with tubular carcinomas. Neither tumour size nor core number predicted diagnostic accuracy.

  11. Motion compensation for MRI-compatible patient-mounted needle guide device: estimation of targeting accuracy in MRI-guided kidney cryoablations

    Science.gov (United States)

    Tokuda, Junichi; Chauvin, Laurent; Ninni, Brian; Kato, Takahisa; King, Franklin; Tuncali, Kemal; Hata, Nobuhiko

    2018-04-01

    Patient-mounted needle guide devices for percutaneous ablation are vulnerable to patient motion. The objective of this study is to develop and evaluate a software system for an MRI-compatible patient-mounted needle guide device that can adaptively compensate for displacement of the device due to patient motion using a novel image-based automatic device-to-image registration technique. We have developed a software system for an MRI-compatible patient-mounted needle guide device for percutaneous ablation. It features fully-automated image-based device-to-image registration to track the device position, and a device controller to adjust the needle trajectory to compensate for the displacement of the device. We performed: (a) a phantom study using a clinical MR scanner to evaluate registration performance; (b) simulations using intraoperative time-series MR data acquired in 20 clinical cases of MRI-guided renal cryoablations to assess its impact on motion compensation; and (c) a pilot clinical study in three patients to test its feasibility during the clinical procedure. FRE, TRE, and success rate of device-to-image registration were mm, mm, and 98.3% for the phantom images. The simulation study showed that the motion compensation reduced the targeting error for needle placement from 8.2 mm to 5.4 mm (p  <  0.0005) in patients under general anesthesia (GA), and from 14.4 mm to 10.0 mm () in patients under monitored anesthesia care (MAC). The pilot study showed that the software registered the device successfully in a clinical setting. Our simulation study demonstrated that the software system could significantly improve targeting accuracy in patients treated under both MAC and GA. Intraprocedural image-based device-to-image registration was feasible.

  12. EUS needle identification comparison and evaluation (NICE) study (with videos)

    Science.gov (United States)

    Tang, Shou-jiang; Vilmann, Andreas S.; Saftoiu, Adrian; Wang, Wanmei; Streba, Costin; Fink, Peter P.; Griswold, Michael; Wu, Ruonan; Dietrich, Christoph F.; Jenssen, Christian; Hocke, Michael; Kantowski, Marcus; Pohl, Jürgen; Fockens, Paul; Annema, Jouke T.; van der Heijden, Erik H.F.M.; Havre, Roald Flesland; Pham, Khanh Do-Cong; Kunda, Rastislav; Deprez, Pierre H.; Mariana, Jinga; Vazquez-Sequeiros, Enrique; Larghi, Alberto; Buscarini, Elisabetta; Fusaroli, Pietro; Lahav, Maor; Puri, Rajesh; Garg, Pramod Kumar; Sharma, Malay; Maluf-Filho, Fauze; Sahai, Anand; Brugge, William R.; Lee, Linda S.; Aslanian, Harry R.; Wang, Andrew Y.; Shami, Vanessa M.; Markowitz, Arnold; Siddiqui, Ali A.; Mishra, Girish; Scheiman, James M.; Isenberg, Gerard; Siddiqui, Uzma D.; Shah, Raj J.; Buxbaum, James; Watson, Rabindra R.; Willingham, Field F.; Bhutani, Manoop S.; Levy, Michael J.; Harris, Cynthia; Wallace, Michael B.; Nolsøe, Christian Pállson; Lorentzen, Torben; Bang, Niels; Sørensen, Sten Mellerup; Gilja, Odd Helge; D’Onofrio, Mirko; Piscaglia, Fabio; Gritzmann, Norbert; Radzina, Maija; Sparchez, Zeno Adrian; Sidhu, Paul S.; Freeman, Simon; McCowan, Timothy C.; de Araujo, Cyrillo Rodrigues; Patel, Akash; del Ali, Mohammad A; Campbell, Garth; Chen, Edward; Vilmann, Peter

    2017-01-01

    Background and Aims Endoscopic ultrasound (EUS)-guided fine-needle aspiration (FNA) or biopsy is widely practiced. Optimal sonographic visualization of the needle is critical for image guided interventions. There are several commercially available needles but no bench-top testing and direct comparison of these needles to reveal their inherent echogenicity. The aims are to provide bench-top data that can be used to guide clinical applications and to promote future device research and development. Methods Descriptive bench-top testing and comparison. Bench-top testing of 8 commonly used EUS-FNA needles (all of 22 gauge in size): SonoTip Pro Control (Medi-Globe); Expect Slimline (Boston Scientific); EchoTip, EchoTip Ultra, EchoTip ProCore High Definition, (Cook Medical); ClearView (Conmed); EZ Shot2 (Olympus); BNX (Beacon Endoscopic); and 2 new prototype needles that are coated by echogenic polymers by Medi-Globe. Blinded evaluation of standardized and unedited videos by 43 EUS endoscopists and 17 radiologists specialized in gastrointestinal ultrasound examination that is unfamiliar with EUS needle devices. Results There was no significant difference in the ratings and rankings of these needles between endosonographers and radiologists. Overall, one prototype needle was rated as the best, ranking 10% to 40% higher than all other needles (p<0.01). Among the commercially available needles, the EchoTip Ultra needle and the ClearView needle were top choices. The EZ Shot 2 needle was ranked statistically lower than other needles (30%–75% worse, p<0.001). Conclusions All FNA needles have their inherent and different echogenicity, and these differences are similarly recognized by EUS endoscopists and radiologists. Needles with polymeric coating from the entire shaft to the needle tip may offer better echogenicity. PMID:26873530

  13. Diagnostic Yield of CT-Guided Percutaneous Transthoracic Needle Biopsy for Diagnosis of Anterior Mediastinal Masses.

    Science.gov (United States)

    Petranovic, Milena; Gilman, Matthew D; Muniappan, Ashok; Hasserjian, Robert P; Digumarthy, Subba R; Muse, Victorine V; Sharma, Amita; Shepard, Jo-Anne O; Wu, Carol C

    2015-10-01

    The purpose of this study was to evaluate the diagnostic yield and accuracy of CT-guided percutaneous biopsy of anterior mediastinal masses and assess prebiopsy characteristics that may help to select patients with the highest diagnostic yield. Retrospective review of all CT-guided percutaneous biopsies of the anterior mediastinum conducted at our institution from January 2003 through December 2012 was performed to collect data regarding patient demographics, imaging characteristics of biopsied masses, presence of complications, and subsequent surgical intervention or medical treatment (or both). Cytology, core biopsy pathology, and surgical pathology results were recorded. A per-patient analysis was performed using two-tailed t test, Fisher's exact test, and Pearson chi-square test. The study cohort included 52 patients (32 men, 20 women; mean age, 49 years) with mean diameter of mediastinal mass of 6.9 cm. Diagnostic yield of CT-guided percutaneous biopsy was 77% (40/52), highest for thymic neoplasms (100% [11/11]). Non-diagnostic results were seen in 12 of 52 patients (23%), primarily in patients with lymphoma (75% [9/12]). Fine-needle aspiration yielded the correct diagnosis in 31 of 52 patients (60%), and core biopsy had a diagnostic rate of 77% (36/47). None of the core biopsies were discordant with surgical pathology. There was no statistically significant difference between the diagnostic and the nondiagnostic groups in patient age, lesion size, and presence of necrosis. The complication rate was 3.8% (2/52), all small self-resolving pneumothoraces. CT-guided percutaneous biopsy is a safe diagnostic procedure with high diagnostic yield (77%) for anterior mediastinal lesions, highest for thymic neoplasms (100%), and can potentially obviate more invasive procedures.

  14. Can concurrent core biopsy and fine needle aspiration biopsy improve the false negative rate of sonographically detectable breast lesions?

    Directory of Open Access Journals (Sweden)

    Chang Tsai-Wang

    2010-07-01

    Full Text Available Abstract Background The aims of this study were to determine the accuracy of concurrent core needle biopsy (CNB and fine needle aspiration biopsy (FNAB for breast lesions and to estimate the false-negative rate using the two methods combined. Methods Over a seven-year period, 2053 patients with sonographically detectable breast lesions underwent concurrent ultrasound-guided CNB and FNAB. The sonographic and histopathological findings were classified into four categories: benign, indeterminate, suspicious, and malignant. The histopathological findings were compared with the definitive excision pathology results. Patients with benign core biopsies underwent a detailed review to determine the false-negative rate. The correlations between the ultrasonography, FNAB, and CNB were determined. Results Eight hundred eighty patients were diagnosed with malignant disease, and of these, 23 (2.5% diagnoses were found to be false-negative after core biopsy. After an intensive review of discordant FNAB results, the final false-negative rate was reduced to 1.1% (p-value = 0.025. The kappa coefficients for correlations between methods were 0.304 (p-value p-value p-value Conclusions Concurrent CNB and FNAB under ultrasound guidance can provide accurate preoperative diagnosis of breast lesions and provide important information for appropriate treatment. Identification of discordant results using careful radiological-histopathological correlation can reduce the false-negative rate.

  15. Automated Real-Time Needle-Guide Tracking for Fast 3-T MR-guided Transrectal Prostate Biopsy: A Feasibility Study

    NARCIS (Netherlands)

    Zamecnik, P.; Schouten, M.G.; Krafft, A.J.; Maier, F.; Schlemmer, H.-P.; Barentsz, J.O.; Bock, M. de; Futterer, J.J.

    2014-01-01

    Purpose To assess the feasibility of automatic needle-guide tracking by using a real-time phase-only cross correlation (POCC) algorithm-based sequence for transrectal 3-T in-bore magnetic resonance (MR)-guided prostate biopsies. Materials and Methods This study was approved by the ethics review

  16. An ultra-high field strength MR image-guided robotic needle delivery system for in-bore small animal interventions.

    Science.gov (United States)

    Gravett, Matthew; Cepek, Jeremy; Fenster, Aaron

    2017-11-01

    The purpose of this study was to develop and validate an image-guided robotic needle delivery system for accurate and repeatable needle targeting procedures in mouse brains inside the 12 cm inner diameter gradient coil insert of a 9.4 T MR scanner. Many preclinical research techniques require the use of accurate needle deliveries to soft tissues, including brain tissue. Soft tissues are optimally visualized in MR images, which offer high-soft tissue contrast, as well as a range of unique imaging techniques, including functional, spectroscopy and thermal imaging, however, there are currently no solutions for delivering needles to small animal brains inside the bore of an ultra-high field MR scanner. This paper describes the mechatronic design, evaluation of MR compatibility, registration technique, mechanical calibration, the quantitative validation of the in-bore image-guided needle targeting accuracy and repeatability, and demonstrated the system's ability to deliver needles in situ. Our six degree-of-freedom, MR compatible, mechatronic system was designed to fit inside the bore of a 9.4 T MR scanner and is actuated using a combination of piezoelectric and hydraulic mechanisms. The MR compatibility and targeting accuracy of the needle delivery system are evaluated to ensure that the system is precisely calibrated to perform the needle targeting procedures. A semi-automated image registration is performed to link the robot coordinates to the MR coordinate system. Soft tissue targets can be accurately localized in MR images, followed by automatic alignment of the needle trajectory to the target. Intra-procedure visualization of the needle target location and the needle were confirmed through MR images after needle insertion. The effects of geometric distortions and signal noise were found to be below threshold that would have an impact on the accuracy of the system. The system was found to have negligible effect on the MR image signal noise and geometric distortion

  17. Confocal fluorescence microscopy for rapid evaluation of invasive tumor cellularity of inflammatory breast carcinoma core needle biopsies.

    Science.gov (United States)

    Dobbs, Jessica; Krishnamurthy, Savitri; Kyrish, Matthew; Benveniste, Ana Paula; Yang, Wei; Richards-Kortum, Rebecca

    2015-01-01

    Tissue sampling is a problematic issue for inflammatory breast carcinoma, and immediate evaluation following core needle biopsy is needed to evaluate specimen adequacy. We sought to determine if confocal fluorescence microscopy provides sufficient resolution to evaluate specimen adequacy by comparing invasive tumor cellularity estimated from standard histologic images to invasive tumor cellularity estimated from confocal images of breast core needle biopsy specimens. Grayscale confocal fluorescence images of breast core needle biopsy specimens were acquired following proflavine application. A breast-dedicated pathologist evaluated invasive tumor cellularity in histologic images with hematoxylin and eosin staining and in grayscale and false-colored confocal images of cores. Agreement between cellularity estimates was quantified using a kappa coefficient. 23 cores from 23 patients with suspected inflammatory breast carcinoma were imaged. Confocal images were acquired in an average of less than 2 min per core. Invasive tumor cellularity estimated from histologic and grayscale confocal images showed moderate agreement by kappa coefficient: κ = 0.48 ± 0.09 (p confocal images require less than 2 min for acquisition and allow for evaluation of invasive tumor cellularity in breast core needle biopsy specimens with moderate agreement to histologic images. We show that confocal fluorescence microscopy can be performed immediately following specimen acquisition and could indicate the need for additional biopsies at the initial visit.

  18. The value of touch imprint cytology of prostate core needle biopsy ...

    African Journals Online (AJOL)

    The value of touch imprint cytology of prostate core needle biopsy specimens ... prostate cancer as indicated by a high prostate serum antigen (PSA) level or ... revealed benign features in 7 and prostatitis in 17, while high-grade prostatic ...

  19. Usefulness of CT fluoroscopy-guided percutaneous needle biopsy in the presence of pneumothorax during biopsy

    International Nuclear Information System (INIS)

    O, Dong Hyun; Cho, Young Jun; Park, Yong Sung; Hwang, Cheol Mok; Kim, Keum Won; Kim, Ji Hyung

    2006-01-01

    When pneumothorax occurs during a percutaneous needle biopsy, the radiologist usually stops the biopsy. We evaluated the usefulness of computed tomographic (CT) fluoroscopy-guided percutaneous needle biopsy in the presence of pneumothorax during biopsy. We performed 288 CT fluoroscopy guided percutaneous needle biopsies to diagnose the pulmonary nodules. Twenty two of these patients had pneumothorax that occurred during the biopsy without obtaining an adequate specimen. After pneumothorax occurred, we performed immediate CT fluoroscopy guided percutaneous needle biopsies using an 18-gauge cutting needle. We evaluated the success rate of the biopsies and also whether or not the pneumothorax progressed. We classified these patients into two groups according to whether the pneumothorax progressed (Group 2) or not (Group 1) by measuring the longest distance between the parietal pleura and the visceral pleura both in the early and late pneumothorax. Additionally, we analyzed the relationship between the progression of pneumothorax after biopsy and 1) the depth of the pulmonary nodule; 2) the number of biopsies; 3) the presence or absence of emphysema at the biopsy site; and 4) the size of the pulmonary nodule. Biopsy was successful in 19 of 22 nodules (86.3%). Of the 19 nodules, 12 (63.2%) were malignant and 7 (36.8%) were benign. Twelve patients (54.5%) were classified as group 1 and 10 patients (45.4%) as group 2. The distance between the lung lesion and pleura showed a statistically significant difference between these two groups: ≤ 1 cm in distance for group 1 (81.8%) and group 2 (18.2%), and > 1 cm in distance for group 1 (30%) and group 2 (70%), ρ 0.05). When early pneumothorax occurs during a biopsy, CT fluoroscopy guided percutaneous needle biopsy is an effective and safe procedure. Aggravation of pneumothorax after biopsy is affected by the depth of the pulmonary nodule

  20. CT-guided procedures: evaluation of a phantom system to teach accurate needle placement

    International Nuclear Information System (INIS)

    Dimmick, S.; Jones, M.; Challen, J.; Iedema, J.; Wattuhewa, U.; Coucher, J.

    2007-01-01

    Aim: To evaluate the use of a phantom system to help teach the basic techniques of accurate CT-guided needle placement, thereby avoiding the risks associated with teaching on patients. Materials and Methods: Gelatine phantoms with five, 1.9 cm embedded spherical wooden targets were constructed. Four trainee operators performed 15 simulated biopsy procedures on the targets (series one) and repeated identical procedures 2 weeks later (series two). Statistical analysis of accuracy of needle placement and subject confidence were performed. Results: Significant sequential improvement in axial plane angular error was noted with the average error decreasing by 0.33 degrees after every five procedures performed (95% CI: -0.58 to -0.08, p = 0.01). Operator confidence indicated significant improvement both within each series and from series one to series two (95% CI: 0.08 to 1.17, p = 0.025 and 95% CI: 0.00 to 0.58, p = 0.05) respectively. However, variability in operator performance made statistically significant improvement in other variables unproven. Conclusion: Despite the study comprising a relatively small number of participants and procedures, it clearly demonstrated the effectiveness of teaching operators to perform CT-guided procedures using a phantom system. Needle placement accuracy significantly improved, with a reduction in axial angular error, and improved operator confidence without the risks associated with training on patients. Three of the operators in this study had never performed a CT-guided procedure previously, and their proficiency, after a relatively short but intense period of training, was impressive. The use of phantoms should be considered routinely for basic training of CT-guided needle placement

  1. Usefulness of normal saline for sealing the needle track after CT-guided lung biopsy

    International Nuclear Information System (INIS)

    Li, Y.; Du, Y.; Luo, T.Y.; Yang, H.F.; Yu, J.H.; Xu, X.X.; Zheng, H.J.; Li, B.

    2015-01-01

    Aim: To determine whether the use of normal saline for sealing the needle track can reduce the incidence of pneumothorax and chest tube placement after computed tomography (CT)-guided lung biopsy. Materials and methods: A prospective, randomised, controlled trial enrolling 322 patients was conducted. All patients were randomly assigned to one of two groups: those in whom the needle track was not sealed with normal saline (n=161, Group A) and those who did receive normal saline (n=161, Group B). CT-guided biopsy was performed with coaxial technique. Normal saline, which ranged from 1–3 ml, was injected while the trocar needle was being withdrawn. Patient characteristics, lesion, and procedure variables were analysed as potential risk variables for occurrence of pneumothorax and chest tube placement. Results: The incidence of pneumothorax was 26.1% in Group A and 6.2% in Group B (p<0.001). Nine patients in Group A and one patient in Group B required chest tube placement (p=0.010). Using multiple logistic regression analysis, smaller lesion size, greater needle–pleural angle, longer lesion–pleural distance, presence of emphysema, and no sealing the needle track with normal saline were significantly associated with an increased risk of pneumothorax, and that the latter three factors were also associated with an increased risk of pneumothorax requiring chest tube placement. Conlusion: Normal saline for sealing the needle track significantly reduces the incidence of pneumothorax and prevents subsequent chest tube placement after CT-guided lung biopsy. - Highlights: • Normal saline is an effective sealant for use in lung biopsy. • This technique reduced the incidence of pneumothorax and chest tube placement. • This technique should be recommended for CT-guided lung biopsy.

  2. Extrapleural paravertebral CT guided fine needle biopsy of subcarinal lymph nodes

    Energy Technology Data Exchange (ETDEWEB)

    Tantawy, Wahid H., E-mail: tantawyw@yahoo.com [Radiology Department, Faculty of Medicine, Ain Shams University, Egypt Abbassyia square, Cairo (Egypt); El-Gemeie, Emad H. [Pathology Department, National Cancer Institute, Fom El Khalige Faculty of Medicine, Cairo University (Egypt); Ibrahim, Ahmed S., E-mail: asibrahima@gmail.com [Radiology Department, Faculty of Medicine, Ain Shams University, Egypt Abbassyia square, Cairo (Egypt); Mohamed, Mona A. [Radiology Department, Faculty of Medicine, Ain Shams University, Egypt Abbassyia square, Cairo (Egypt)

    2012-10-15

    Purpose: To report our experience in CT guided extrapleural paravertebral subcarinal lymph biopsy using a thin 25 gauge (25 G) thin needle without the need of injection of saline to widen the mediastinum. Materials and methods: Biopsy was performed using a 25 G needle which was advanced lateral to the vertebral body between the endothoracic fascia and the parietal pleura to gain access to subcarinal lymph nodes. One hundred and forty one patients were included in the study (74 females, 57 males). No artificial widening of the mediastinum using saline injection was required. The study was performed in the presence of a cytopathologist; sensitivity and specificity rates were calculated. Complications were documented for each case especially for pneumothorax and haemorrhage. Results: Cytopathological diagnosis was reached in all cases. All re-aspirations were done in the same session to reach a primary diagnosis at the time of the biopsy. Imunophenotyping study was done in 94 cases to confirm the primary diagnosis and to classify the malignant lesions. No pneumothorax was encountered. Small haematomas were noted in 5 cases (3.5%). Cytopathology showed a sensitivity of 97.2% and specificity of 100%. By adding immunophenotyping a 100% sensitivity and specificity was achieved. Conclusion: Fine needle aspiration cytology (FNAC) using a 25 gauge needle for subcarinal lymph nodes via a percutaneous extrapleural paravertebral CT guided approach is a safe, minimally invasive, and tolerable procedure yielding a high sensitivity and specificity rates without the need of artificial widening.

  3. Extrapleural paravertebral CT guided fine needle biopsy of subcarinal lymph nodes

    International Nuclear Information System (INIS)

    Tantawy, Wahid H.; El-Gemeie, Emad H.; Ibrahim, Ahmed S.; Mohamed, Mona A.

    2012-01-01

    Purpose: To report our experience in CT guided extrapleural paravertebral subcarinal lymph biopsy using a thin 25 gauge (25 G) thin needle without the need of injection of saline to widen the mediastinum. Materials and methods: Biopsy was performed using a 25 G needle which was advanced lateral to the vertebral body between the endothoracic fascia and the parietal pleura to gain access to subcarinal lymph nodes. One hundred and forty one patients were included in the study (74 females, 57 males). No artificial widening of the mediastinum using saline injection was required. The study was performed in the presence of a cytopathologist; sensitivity and specificity rates were calculated. Complications were documented for each case especially for pneumothorax and haemorrhage. Results: Cytopathological diagnosis was reached in all cases. All re-aspirations were done in the same session to reach a primary diagnosis at the time of the biopsy. Imunophenotyping study was done in 94 cases to confirm the primary diagnosis and to classify the malignant lesions. No pneumothorax was encountered. Small haematomas were noted in 5 cases (3.5%). Cytopathology showed a sensitivity of 97.2% and specificity of 100%. By adding immunophenotyping a 100% sensitivity and specificity was achieved. Conclusion: Fine needle aspiration cytology (FNAC) using a 25 gauge needle for subcarinal lymph nodes via a percutaneous extrapleural paravertebral CT guided approach is a safe, minimally invasive, and tolerable procedure yielding a high sensitivity and specificity rates without the need of artificial widening

  4. Comparison of CT Fluoroscopy-Guided Manual and CT-Guided Robotic Positioning System for In Vivo Needle Placements in Swine Liver

    International Nuclear Information System (INIS)

    Cornelis, F.; Takaki, H.; Laskhmanan, M.; Durack, J. C.; Erinjeri, J. P.; Getrajdman, G. I.; Maybody, M.; Sofocleous, C. T.; Solomon, S. B.; Srimathveeravalli, G.

    2015-01-01

    PurposeTo compare CT fluoroscopy-guided manual and CT-guided robotic positioning system (RPS)-assisted needle placement by experienced IR physicians to targets in swine liver.Materials and MethodsManual and RPS-assisted needle placement was performed by six experienced IR physicians to four 5 mm fiducial seeds placed in swine liver (n = 6). Placement performance was assessed for placement accuracy, procedure time, number of confirmatory scans, needle manipulations, and procedure radiation dose. Intra-modality difference in performance for each physician was assessed using paired t test. Inter-physician performance variation for each modality was analyzed using Kruskal–Wallis test.ResultsPaired comparison of manual and RPS-assisted placements to a target by the same physician indicated accuracy outcomes was not statistically different (manual: 4.53 mm; RPS: 4.66 mm; p = 0.41), but manual placement resulted in higher total radiation dose (manual: 1075.77 mGy/cm; RPS: 636.4 mGy/cm; p = 0.03), required more confirmation scans (manual: 6.6; RPS: 1.6; p < 0.0001) and needle manipulations (manual: 4.6; RPS: 0.4; p < 0.0001). Procedure time for RPS was longer than manual placement (manual: 6.12 min; RPS: 9.7 min; p = 0.0003). Comparison of inter-physician performance during manual placement indicated significant differences in the time taken to complete placements (p = 0.008) and number of repositions (p = 0.04) but not in other study measures (p > 0.05). Comparison of inter-physician performance during RPS-assisted placement suggested statistically significant differences in procedure time (p = 0.02) and not in other study measures (p > 0.05).ConclusionsCT-guided RPS-assisted needle placement reduced radiation dose, number of confirmatory scans, and needle manipulations when compared to manual needle placement by experienced IR physicians, with equivalent accuracy

  5. Comparison of CT Fluoroscopy-Guided Manual and CT-Guided Robotic Positioning System for In Vivo Needle Placements in Swine Liver

    Energy Technology Data Exchange (ETDEWEB)

    Cornelis, F.; Takaki, H. [Memorial Sloan-Kettering Cancer Center, Interventional Radiology Service, Department of Radiology (United States); Laskhmanan, M. [Perfint Healthcare Inc (India); Durack, J. C.; Erinjeri, J. P.; Getrajdman, G. I.; Maybody, M.; Sofocleous, C. T.; Solomon, S. B.; Srimathveeravalli, G., E-mail: srimaths@mskcc.org [Memorial Sloan-Kettering Cancer Center, Interventional Radiology Service, Department of Radiology (United States)

    2015-10-15

    PurposeTo compare CT fluoroscopy-guided manual and CT-guided robotic positioning system (RPS)-assisted needle placement by experienced IR physicians to targets in swine liver.Materials and MethodsManual and RPS-assisted needle placement was performed by six experienced IR physicians to four 5 mm fiducial seeds placed in swine liver (n = 6). Placement performance was assessed for placement accuracy, procedure time, number of confirmatory scans, needle manipulations, and procedure radiation dose. Intra-modality difference in performance for each physician was assessed using paired t test. Inter-physician performance variation for each modality was analyzed using Kruskal–Wallis test.ResultsPaired comparison of manual and RPS-assisted placements to a target by the same physician indicated accuracy outcomes was not statistically different (manual: 4.53 mm; RPS: 4.66 mm; p = 0.41), but manual placement resulted in higher total radiation dose (manual: 1075.77 mGy/cm; RPS: 636.4 mGy/cm; p = 0.03), required more confirmation scans (manual: 6.6; RPS: 1.6; p < 0.0001) and needle manipulations (manual: 4.6; RPS: 0.4; p < 0.0001). Procedure time for RPS was longer than manual placement (manual: 6.12 min; RPS: 9.7 min; p = 0.0003). Comparison of inter-physician performance during manual placement indicated significant differences in the time taken to complete placements (p = 0.008) and number of repositions (p = 0.04) but not in other study measures (p > 0.05). Comparison of inter-physician performance during RPS-assisted placement suggested statistically significant differences in procedure time (p = 0.02) and not in other study measures (p > 0.05).ConclusionsCT-guided RPS-assisted needle placement reduced radiation dose, number of confirmatory scans, and needle manipulations when compared to manual needle placement by experienced IR physicians, with equivalent accuracy.

  6. Safety and correlation of test results of combined ultrasound-guided fine-needle aspiration and needle core biopsy of the canine spleen.

    Science.gov (United States)

    Watson, Adam T; Penninck, Dominique; Knoll, Joyce S; Keating, John H; Sutherland-Smith, James

    2011-01-01

    The safety and diagnostic value of combined splenic fine-needle aspiration (FNA) and needle core biopsy (NCB) is unknown. Forty-one dogs with splenic lesions were studied prospectively. Safety was assessed in 38 dogs and no complications were encountered. Initially, clinical and anatomic pathologists reviewed each FNA and NCB sample, respectively, without knowledge of the other's results. Diagnoses were categorized as neoplastic, benign, inflammatory, normal, or nondiagnostic. The level of agreement between sampling methods was categorized as complete, partial, disagreement, or not available. Test correlation was performed in 40 dogs. Nondiagnostic results occurred in 5/40 NCB (12.5%) and no FNA samples. Neoplasia was diagnosed in 17/40 dogs (42.5%), benign changes in 20/40 dogs (50%), inflammatory disorders in 0/40 dogs, and normal 2/40 dogs (5%). One of the 40 dogs (2.5%) had a diagnosis that was equivocal for neoplasia on both tests and therefore was not categorized. Of the 35 dogs that had diagnostic samples, cytopathologic and histopathologic diagnoses agreed completely in 18/35 dogs (51.4%), partially in 3/35 dogs (8.6%), and were in disagreement in 14/35 dogs (40.0%). Pathologists collaboratively reviewed diagnoses that were in disagreement or partial agreement and altered their individual diagnoses in 6/17 dogs (35.3%) to be within partial or complete agreement, respectively. Percutaneous FNA and NCB can be performed safely in dogs with sonographic splenic changes. Results suggest that adding NCB to FNA provides complementary information in dogs with suspected splenic neoplasia. This combined protocol may improve detection of splenic neoplasia and provide neoplastic subclassification. © 2010 Veterinary Radiology & Ultrasound.

  7. Ultrasound guided core biopsy of suspicious mammographic calcifications using high frequency and power Doppler ultrasound

    International Nuclear Information System (INIS)

    Teh, W.L.; Wilson, A.R.M; Evans, A.J.; Burrell, H.; Pinder, S.E.; Ellis, I.O.

    2000-01-01

    AIM: The pre-operative diagnosis of suspicious mammographic microcalcifications usually requires stereotactic needle biopsy. The aim of this study was to evaluate if high frequency 13 MHz ultrasound (HFUS) and power Doppler (PD) can aid visualization and biopsy of microcalcifications. MATERIALS AND METHODS: Forty-four consecutive patients presenting with microcalcifications without associated mammographic or palpable masses were examined with HFUS and PD. Ultrasound-guided core biopsy (USCB) was performed where possible. Stereotactic biopsy was carried out when US-guided biopsy was unsuccessful. Surgery was performed if a diagnosis of malignancy was made on core biopsy or if the repeat core biopsy was non-diagnostic. RESULTS: Forty-one patients (93%) had ultrasound abnormalities corresponding to mammographic calcification. USCB was performed on 37 patients. In 29/37, USCB obtained a definitive result (78.4%). USCB was non-diagnostic in 4/9 benign (44.4%) and 4/28 (14.3%) malignant lesions biopsied. The complete and absolute sensitivities for malignancy using USCB were 85.7% (24/28) and 81% (23/28), respectively. USCB correctly identified invasive disease in 12/23 (52.2%) cases. There was no significant difference in the presence of abnormal flow on PD between benign and malignant lesions. However, abnormal PD vascularity was present in 43.5% of invasive cancer and was useful in directing successful biopsy in eight cases. CONCLUSION: The combination of high frequency US with PD is useful in the detection and guidance of successful needle biopsy of microcalcifications particularly where there is an invasive focus within larger areas of DCIS. Teh, W.L. (2000)

  8. Study on design and cutting parameters of rotating needles for core biopsy.

    Science.gov (United States)

    Giovannini, Marco; Ren, Huaqing; Cao, Jian; Ehmann, Kornel

    2018-06-15

    Core needle biopsies are widely adopted medical procedures that consist in the removal of biological tissue to better identify a lesion or an abnormality observed through a physical exam or a radiology scan. These procedures can provide significantly more information than most medical tests and they are usually performed on bone lesions, breast masses, lymph nodes and the prostate. The quality of the samples mainly depends on the forces exerted by the needle during the cutting process. The reduction of these forces is critical to extract high-quality tissue samples. The most critical factors that affect the cutting forces are the geometry of the needle tip and its motion while it is penetrating the tissue. However, optimal needle tip configurations and cutting parameters are not well established for rotating insertions. In this paper, the geometry and cutting forces of hollow needles are investigated. The fundamental goal of this study is to provide a series of guidelines for clinicians and surgeons to properly select the optimal tip geometries and speeds. Analytical models related to the cutting angles of several needle tip designs are presented and compared. Several needle tip geometries were manufactured from a 14-gauge cannula, commonly adopted during breast biopsies. The needles were then tested at different speeds and on different phantom tissues. According to these experimental measurements recommendations were formulated for rotating needle insertions. The findings of this study can be applied and extended to several biopsy procedures in which a cannula is used to extract tissue samples. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Patient identification error among prostate needle core biopsy specimens--are we ready for a DNA time-out?

    Science.gov (United States)

    Suba, Eric J; Pfeifer, John D; Raab, Stephen S

    2007-10-01

    Patient identification errors in surgical pathology often involve switches of prostate or breast needle core biopsy specimens among patients. We assessed strategies for decreasing the occurrence of these uncommon and yet potentially catastrophic events. Root cause analyses were performed following 3 cases of patient identification error involving prostate needle core biopsy specimens. Patient identification errors in surgical pathology result from slips and lapses of automatic human action that may occur at numerous steps during pre-laboratory, laboratory and post-laboratory work flow processes. Patient identification errors among prostate needle biopsies may be difficult to entirely prevent through the optimization of work flow processes. A DNA time-out, whereby DNA polymorphic microsatellite analysis is used to confirm patient identification before radiation therapy or radical surgery, may eliminate patient identification errors among needle biopsies.

  10. Training and certification in endobronchial ultrasound-guided transbronchial needle aspiration

    Science.gov (United States)

    Konge, Lars; Nayahangan, Leizl Joy; Clementsen, Paul Frost

    2017-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) plays a key role in the staging of lung cancer, which is crucial for allocation to surgical treatment. EBUS-TBNA is a complicated procedure and simulation-based training is helpful in the first part of the long learning curve prior to performing the procedure on actual patients. New trainees should follow a structured training programme consisting of training on simulators to proficiency as assessed with a validated test followed by supervised practice on patients. The simulation-based training is superior to the traditional apprenticeship model and is recommended in the newest guidelines. EBUS-TBNA and oesophageal ultrasound-guided fine needle aspiration (EUS-FNA or EUS-B-FNA) are complementary to each other and the combined techniques are superior to either technique alone. It is logical to learn and to perform the two techniques in combination, however, for lung cancer staging solely EBUS-TBNA simulators exist, but hopefully in the future simulation-based training in EUS will be possible. PMID:28840013

  11. Needle segmentation using 3D Hough transform in 3D TRUS guided prostate transperineal therapy

    Energy Technology Data Exchange (ETDEWEB)

    Qiu Wu [Department of Biomedical Engineering, School of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China); Imaging Research Laboratories, Robarts Research Institute, Western University, London, Ontario N6A 5K8 (Canada); Yuchi Ming; Ding Mingyue [Department of Biomedical Engineering, School of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China); Tessier, David; Fenster, Aaron [Imaging Research Laboratories, Robarts Research Institute, University of Western Ontario, London, Ontario N6A 5K8 (Canada)

    2013-04-15

    Purpose: Prostate adenocarcinoma is the most common noncutaneous malignancy in American men with over 200 000 new cases diagnosed each year. Prostate interventional therapy, such as cryotherapy and brachytherapy, is an effective treatment for prostate cancer. Its success relies on the correct needle implant position. This paper proposes a robust and efficient needle segmentation method, which acts as an aid to localize the needle in three-dimensional (3D) transrectal ultrasound (TRUS) guided prostate therapy. Methods: The procedure of locating the needle in a 3D TRUS image is a three-step process. First, the original 3D ultrasound image containing a needle is cropped; the cropped image is then converted to a binary format based on its histogram. Second, a 3D Hough transform based needle segmentation method is applied to the 3D binary image in order to locate the needle axis. The position of the needle endpoint is finally determined by an optimal threshold based analysis of the intensity probability distribution. The overall efficiency is improved through implementing a coarse-fine searching strategy. The proposed method was validated in tissue-mimicking agar phantoms, chicken breast phantoms, and 3D TRUS patient images from prostate brachytherapy and cryotherapy procedures by comparison to the manual segmentation. The robustness of the proposed approach was tested by means of varying parameters such as needle insertion angle, needle insertion length, binarization threshold level, and cropping size. Results: The validation results indicate that the proposed Hough transform based method is accurate and robust, with an achieved endpoint localization accuracy of 0.5 mm for agar phantom images, 0.7 mm for chicken breast phantom images, and 1 mm for in vivo patient cryotherapy and brachytherapy images. The mean execution time of needle segmentation algorithm was 2 s for a 3D TRUS image with size of 264 Multiplication-Sign 376 Multiplication-Sign 630 voxels. Conclusions

  12. Needle segmentation using 3D Hough transform in 3D TRUS guided prostate transperineal therapy

    International Nuclear Information System (INIS)

    Qiu Wu; Yuchi Ming; Ding Mingyue; Tessier, David; Fenster, Aaron

    2013-01-01

    Purpose: Prostate adenocarcinoma is the most common noncutaneous malignancy in American men with over 200 000 new cases diagnosed each year. Prostate interventional therapy, such as cryotherapy and brachytherapy, is an effective treatment for prostate cancer. Its success relies on the correct needle implant position. This paper proposes a robust and efficient needle segmentation method, which acts as an aid to localize the needle in three-dimensional (3D) transrectal ultrasound (TRUS) guided prostate therapy. Methods: The procedure of locating the needle in a 3D TRUS image is a three-step process. First, the original 3D ultrasound image containing a needle is cropped; the cropped image is then converted to a binary format based on its histogram. Second, a 3D Hough transform based needle segmentation method is applied to the 3D binary image in order to locate the needle axis. The position of the needle endpoint is finally determined by an optimal threshold based analysis of the intensity probability distribution. The overall efficiency is improved through implementing a coarse-fine searching strategy. The proposed method was validated in tissue-mimicking agar phantoms, chicken breast phantoms, and 3D TRUS patient images from prostate brachytherapy and cryotherapy procedures by comparison to the manual segmentation. The robustness of the proposed approach was tested by means of varying parameters such as needle insertion angle, needle insertion length, binarization threshold level, and cropping size. Results: The validation results indicate that the proposed Hough transform based method is accurate and robust, with an achieved endpoint localization accuracy of 0.5 mm for agar phantom images, 0.7 mm for chicken breast phantom images, and 1 mm for in vivo patient cryotherapy and brachytherapy images. The mean execution time of needle segmentation algorithm was 2 s for a 3D TRUS image with size of 264 × 376 × 630 voxels. Conclusions: The proposed needle segmentation

  13. The diagnostic significance of CT-guided percutaneous transthoracic cutting needle biopsy for pulmonary lesions

    International Nuclear Information System (INIS)

    Wang Hui; Zhang Fuchen; Ji Hongjian; Chen Liping

    2009-01-01

    Objective: To evaluate the diagnostic significance of CT-guided percutaneous transthoracic cutting needle biopsy for pulmonary lesions. Methods: The clinical data of CT-guided transthoracic cutting needle biopsy in 436 patients performed in past 10 years were retrospectively analyzed. Of 436 cases with pulmonary lesions, primary lung cancer was confirmed in 341, pulmonary metastasis in 62, non-malignant lesions in 33. The diagnostic accuracy and sensitivity were statistically analyzed. The occurrence of complications was discussed. Results: The diagnostic accuracy rate and sensitivity rate in primary lung cancer group were 94.7% and 94.1% respectively, in pulmonary metastasis group were 58.2% and 51.6% respectively and in non-malignant lesions group were 57.6% and 57.6% respectively. The successful rate of biopsy was 97.9%. The occurrence of complications was 15.6%. Conclusion: CT-guided percutaneous transthoracic cutting needle biopsy is a safe and valuable diagnostic technique with high diagnostic accuracy and less complications. It is very helpful in confirming the diagnosis in the patients with suspected primary pulmonary cancer, although the technical procedures need to be further improved for metastatic and non-malignant lung lesions. (authors)

  14. The factor analysis of the incidence of pneumothorax after CT-guided transthoracic needle aspiration biopsy

    International Nuclear Information System (INIS)

    Zhong Tao; Yu Hongguang; Wang Yong; Yang Sifu; Wang Xiaoxuan

    2007-01-01

    Objective: To analyze the impact of multiple factors on the incidence of pneumothorax associated with CT-guided transthoracic needle aspiration biopsy. Methods: The sign of pneumothorax after 162 cases (lesion diameter from 1 cm to 6 cm) CT-guided transthoracic needle aspiration biopsy was observed and its relationship with multivariate factors were analyzed by multivariate logistic regression model. Results: Thirty-two cases presented pneumothorax accounting for 19. 8%. Single variate analysis showed that the sign of pneumothorax related to intercurrent COPD, distance from lesion and chest wall, needle dwelling time and lesion diameter. 67 patients of intercurrent COPD with postoperative pneumothorax occurred in 22 cases (32.8%); With respect to those having lesions close to the chest wall (48 cases), and the cases with the distance between the chest wall and lesions less than 2 cm (55 cases) and greater than 2 cm (59 cases), the postoperative pneumothorax occurred in 0, 14 (25.5%), 18 (30.5%) cases respectively; For those patients with needle in the chest residence time of less than 10 minutes (82 cases), 10-20 minutes (51 cases), more than 20 minutes (28 cases) after the occurrence of pneumothorax were 8 (9.6%), 10(19.6%), 14 (50%) cases respectively; In contrast, those with lesion diameter less than 2 cm (65 cases), 2-4 cm(52 cases), more than 4cm(45 cases) were 19 (29.2%), 8 (15.4%) and 5 (11.1% ) respectively. The multivariate logistic regression analysis showed that the prior three factor's were risk factors of pneumothorax (OR=4.652, 4.030, 2.855 respectively). Conclusions: To avoid the pneumothorax, caution must be taken with respect to CT-guided transthoracic needle aspiration biopsy, patients with intercurrent COPD, long distance between lesion and chest wall, and smaller lesion diameter. For operation the needle dwell time within thorax should be minimized. (authors)

  15. Radiographic-guided fine-needle aspiration of nonpalpable breast lesions

    International Nuclear Information System (INIS)

    Helvie, M.A.; Baker, D.E.; Adler, D.D.; Andersson, I.; Naylor, B.; Buckwalter, K.

    1989-01-01

    The authors have performed radiographically guided fine-needle aspirations (FNA) on 215 nonpalpable mammographically detected breast lesions, using a coordinate grid localization system. Aspirates were classified into five cytologic groups. With the most stringent cytologic criteria, the sensitivity was 98% and the specificity 95% for the detection of carcinoma. However, according to these strict cytologic criteria, only 46% of aspirates contained representative material. Forty-two of 74 lesions undergoing biopsy proved malignant. Sixteen percent of patients did not compete adequate mammographic follow-up. High sensitivity and specificity can be achieved with radiographically guided FNA. However, management decisions ultimately require integration of mammographic findings with cytologic results. Close cooperation between mammographer, surgeon, cytopathologist, and patients is mandatory for successful operation

  16. Two-dimensional mapping of needle visibility with linear and curved array for ultrasound-guided interventional procedure

    Science.gov (United States)

    Susanti, Hesty; Suprijanto, Kurniadi, Deddy

    2018-02-01

    Needle visibility in ultrasound-guided technique has been a crucial factor for successful interventional procedure. It has been affected by several factors, i.e. puncture depth, insertion angle, needle size and material, and imaging technology. The influences of those factors made the needle not always well visible. 20 G needles of 15 cm length (Nano Line, facet) were inserted into water bath with variation of insertion angles and depths. Ultrasound measurements are performed with BK-Medical Flex Focus 800 using 12 MHz linear array and 5 MHz curved array in Ultrasound Guided Regional Anesthesia mode. We propose 3 criteria to evaluate needle visibility, i.e. maximum intensity, mean intensity, and the ratio between minimum and maximum intensity. Those criteria were then depicted into representative maps for practical purpose. The best criterion candidate for representing the needle visibility was criterion 1. Generally, the appearance pattern of the needle from this criterion was relatively consistent, i.e. for linear array, it was relatively poor visibility in the middle part of the shaft, while for curved array, it is relatively better visible toward the end of the shaft. With further investigations, for example with the use of tissue-mimicking phantom, the representative maps can be built for future practical purpose, i.e. as a tool for clinicians to ensure better needle placement in clinical application. It will help them to avoid the "dead" area where the needle is not well visible, so it can reduce the risks of vital structures traversing and the number of required insertion, resulting in less patient morbidity. Those simple criteria and representative maps can be utilized to evaluate general visibility patterns of the needle in vast range of needle types and sizes in different insertion media. This information is also important as an early investigation for future research of needle visibility improvement, i.e. the development of beamforming strategies and

  17. A serious game for learning ultrasound-guided needle placement skills.

    Science.gov (United States)

    Chan, Wing-Yin; Qin, Jing; Chui, Yim-Pan; Heng, Pheng-Ann

    2012-11-01

    Ultrasound-guided needle placement is a key step in a lot of radiological intervention procedures such as biopsy, local anesthesia and fluid drainage. To help training future intervention radiologists, we develop a serious game to teach the skills involved. We introduce novel techniques for realistic simulation and integrate game elements for active and effective learning. This game is designed in the context of needle placement training based on the some essential characteristics of serious games. Training scenarios are interactively generated via a block-based construction scheme. A novel example-based texture synthesis technique is proposed to simulate corresponding ultrasound images. Game levels are defined based on the difficulties of the generated scenarios. Interactive recommendation of desirable insertion paths is provided during the training as an adaptation mechanism. We also develop a fast physics-based approach to reproduce the shadowing effect of needles in ultrasound images. Game elements such as time-attack tasks, hints and performance evaluation tools are also integrated in our system. Extensive experiments are performed to validate its feasibility for training.

  18. Endoscopic Ultrasound-Guided Fine Needle Aspiration versus Percutaneous Ultrasound-Guided Fine Needle Aspiration in Diagnosis of Focal Pancreatic Masses.

    Science.gov (United States)

    Okasha, Hussein Hassan; Naga, Mazen Ibrahim; Esmat, Serag; Naguib, Mohamed; Hassanein, Mohamed; Hassani, Mohamed; El-Kassas, Mohamed; Mahdy, Reem Ezzat; El-Gemeie, Emad; Farag, Ali Hassan; Foda, Ayman Mohamed

    2013-10-01

    Pancreatic carcinoma is one of the leading cancer morbidity and mortality world-wide. Controversy has arisen about whether the percutaneous approach with computed tomography/ultrasonography-guidance fine needle aspiration (US-FNA) or endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is the preferred method to obtain diagnostic tissue. Our purpose of this study is to compare between the diagnostic accuracy of EUS-FNA and percutaneous US-FNA in diagnosis of pancreatic cancer. A total of 197 patients with pancreatic masses were included in the study, 125 patients underwent US-FNA (Group 1) and 72 patients underwent EUS-FNA (Group 2). EUS-FNA has nearly the same accuracy (88.9%) as US-FNA (87.2%) in diagnosis of pancreatic cancer. The sensitivity, specificity, positive predictive value and negative predictive value for EUS-FNA was 84%, 100%, 100%, 73.3% respectively. It was 85.5%, 90.4%, 94.7%, 76% respectively for US-FNA. EUS-FNA had a lower complication rate (1.38%) than US-FNA (5.6%). EUS-FNA has nearly the same accuracy as US-FNA of pancreatic masses with a lower complication rate.

  19. Development and Evaluation of a Novel Curved Biopsy Device for CT-Guided Biopsy of Lesions Unreachable Using Standard Straight Needle Trajectories

    Energy Technology Data Exchange (ETDEWEB)

    Schulze-Hagen, Maximilian Franz, E-mail: mschulze@ukaachen.de; Pfeffer, Jochen; Zimmermann, Markus; Liebl, Martin [University Hospital RWTH Aachen, Department of Diagnostic and Interventional Radiology (Germany); Stillfried, Saskia Freifrau von [University Hospital RWTH Aachen, Department of Pathology (Germany); Kuhl, Christiane; Bruners, Philipp; Isfort, Peter [University Hospital RWTH Aachen, Department of Diagnostic and Interventional Radiology (Germany)

    2017-06-15

    PurposeTo evaluate the feasibility of a novel curved CT-guided biopsy needle prototype with shape memory to access otherwise not accessible biopsy targets.Methods and MaterialsA biopsy needle curved by 90° with specific radius was designed. It was manufactured using nitinol to acquire shape memory, encased in a straight guiding trocar to be driven out for access of otherwise inaccessible targets. Fifty CT-guided punctures were conducted in a biopsy phantom and 10 CT-guided punctures in a swine corpse. Biposies from porcine liver and muscle tissue were separately gained using the biopsy device, and histological examination was performed subsequently.ResultsMean time for placement of the trocar and deployment of the inner biopsy needle was ~205 ± 69 and ~93 ± 58 s, respectively, with a mean of ~4.5 ± 1.3 steps to reach adequate biopsy position. Mean distance from the tip of the needle to the target was ~0.7 ± 0.8 mm. CT-guided punctures in the swine corpse took relatively longer and required more biopsy steps (~574 ± 107 and ~380 ± 148 s, 8 ± 2.6 steps). Histology demonstrated appropriate tissue samples in nine out of ten cases (90%).ConclusionsTargets that were otherwise inaccessible via standard straight needle trajectories could be successfully reached with the curved biopsy needle prototype. Shape memory and preformed size with specific radius of the curved needle simplify the target accessibility with a low risk of injuring adjacent structures.

  20. Usefulness of CT-guided trans-bronchial needle aspiration biopsy for mediastinal lymph nodes

    International Nuclear Information System (INIS)

    Cui Bing; Rong Fu

    2001-01-01

    Objective: To determine the nature of enlarged mediastinal lymph nodes, the study of CT-guided trans-bronchial needle aspiration biopsy (CT-TBNA) was conducted. Methods: According to classification and locating standard of mediastinal lymph nodes, CT-TBNA was performed in 158 mediastinal lymph nodes of 73 patients, including 54 primary lung cancer with enlarged mediastinal lymph nodes, 5 malignant lymphoma, 3 mediastinal abscess and 11 mediastinal inflammatory adenopathy. Results: CT confirmed that the needles were inside all 158 lymph nodes. Adequate aspirates for histologic and/or cytologic diagnosis were obtained in 136 of 158(86%) lymph node biopsies. No serious complications occurred. Conclusion: Locating standard of CT-guided TBNA was reliable. Puncture was safe and cost-effective. CT-TBNA was important for ascertaining the nature of mediastinal adenopathy and staging of neoplasms

  1. Ultrasound-guided fine needle aspiration in the diagnosis of peripheral nerve sheath tumors in 4 dogs

    Science.gov (United States)

    da Costa, Ronaldo C.; Parent, Joane M.; Dobson, Howard; Ruotsalo, Kristiina; Holmberg, David; Duque, M. Carolina; Poma, Roberto

    2008-01-01

    Ultrasound-guided fine needle aspiration was used in establishing the diagnosis in 4 cases of malignant peripheral nerve sheath tumor. Sonographic and cytologic characteristics are discussed. Because of its availability and ease of use, axillary ultrasonography with fine needle aspiration can be an initial diagnostic step for suspected brachial plexus tumors. PMID:18320983

  2. Ultrasound-Guided Fine-Needle Aspiration Biopsy of Multiple Thyroid Nodules

    International Nuclear Information System (INIS)

    Kim, Ji Dae; Bae, Il Hun; Lee, Seung Young; Han, Gi Seok; Cha, Sang Hun; Kim, Sung Jin; Park, Kil Sun; Koong, Sung Soo; Lee, Ok Jun

    2006-01-01

    To standardize the number of nodules which necessitates ultrasound-guided, fine-needle, aspiration biopsy in patients who have multiple thyroid nodules with the same sonographic characteristics as each other. From February, 2002 to March, 2004, among patients whose diagnosis was confirmed by ultrasound-guided, fine-needle, aspiration biopsy, 545 nodules of 203 patients were found in sonography with more than two thyroid nodules. Each thyroid gland nodule was classified on a score from 0 to 2 points on the basis of the following 5 characteristics: internal content, margin, echogenicity, shape and calcification in sonography. When the score of all characteristics was the same, by deciding on nodules with the same sonographic characteristics and with the score of at least one characteristic being different, we divided the nodules with different sonographic characteristics in a patient. By methods such as given in the preceding descriptions, patients with multiple thyroid nodules were separated into two groups: one in which all nodules had the same sonographic characteristics and another in which nodules have at least one different sonographic characteristic. Then, each pathologic result was searched for the same case and different case in each patient group. Among the 203 patients who were diagnosed with multiple thyroid nodules in ultrasonography, 79 patients (38.9%) had nodules with the same ultrasonographic characteristics and 124 patients (61.1%) had nodules with at least one different ultrasonographic characteristic. All 79 patient's nodules with the same ultrasonographic characteristics in each patient showed the same pathologic result in all cases (100.0%) and there was no case showing a different pathologic result. Otherwise, among the 124 patient's nodules with different ultrasonographic characteristics, each patient showed the same pathologic result in 111 (89.5%) and different pathologic result in 13 (10.5%). In patients who have multiple thyroid nodules

  3. Transrectal ultrasound and needle biopsy of the prostate

    Directory of Open Access Journals (Sweden)

    Tomaž Smrkolj

    2016-01-01

    Full Text Available In the last 25 years widespread use of prostatic specific antigen caused a stage migration of prostate cancer towards localized disease at diagnosis, which resulted in transrectal ultrasound biopsy to become standard in clinical practice. Transrectal ultrasound examination of the prostate is used to diagnose benign prostatic diseases, e.g. benign prostatic enlargement, prostatitis, prostatic and seminal vesicle cysts. It is also important in detection of obstructive causes of male infertility. Transrectal ultrasound examination is performed most often in needle biopsy for prostate cancer diagnosis. Besides guiding systematic tissue core biopsy, characteristic ultrasound changes enables target biopsies of suspect areas. The article describes indications, contraindications, antibiotic prophylaxis, various biopsy templates and complications of the needle biopsy. Experience with transrectal ultrasound guided biopsy at Department of urology at University medical center in Ljubljana is presented.

  4. Ultrasound-Guided Miniscalpel-Needle Release versus Dry Needling for Chronic Neck Pain: A Randomized Controlled Trial

    Directory of Open Access Journals (Sweden)

    Yongjun Zheng

    2014-01-01

    Full Text Available Objective. To compare ultrasound-guided miniscalpel-needle (UG-MSN release versus ultrasound-guided dry needling (UG-DN for chronic neck pain. Methods. A total of 169 patients with chronic neck pain were randomized to receive either UG-MSN release or UG-DN. Before treatment and at 3 and 6 months posttreatment, pain was measured using a 10-point visual analogue scale (VAS. Neck function was examined using the neck disability index. Health-related quality of life was examined using the physical component score (PCS and mental component score (MCS of the SF-36 health status scale. Results. Patients in the UG-MSN release had greater improvement on the VAS (by 2 points at 3 months and 0.9 points at 6 months versus in the UG-DN arm; (both P<0.0001. Patients receiving UG-MSN release also showed significantly lower scores on the adjusted neck disability index, as well as significantly lower PCS. No severe complications were observed. Conclusion. UG-MSN release was superior to UG-DN in reducing pain intensity and neck disability in patients with chronic neck pain and was not associated with severe complications. The procedural aspects in the two arms were identical; however, we did not verify the blinding success. As such, the results need to be interpreted with caution.

  5. Ultrasonography-Guided Fine Needle Aspiration Cytology of Cervical Lymphadenopathy: Comparative Study of the Cytological Adequacy Using of 21- and 23- Gauge Needles

    International Nuclear Information System (INIS)

    Beak, Jin Wook; KIm, Dong Wook; Kim, Bo Mi

    2011-01-01

    To assess the difference in the cytological adequacy of ultrasonography (US)-guided fine needle aspiration cytology (US-FNAC) for cervical lymphadenopathy using 21 and 23 gauge needles. US-FNACs were separately performed on two cervical lymph nodes and in each patient using 21 gauge (group A) and 23 gauge (group B) needles, respectively. We used 4 grade classifications for the cytological analysis of each slide and compared the cytological adequacy of US-FNAC for cervical lymphadenopathy in the two groups. We performed US-FNACs on 58 cervical lymph nodes from 29 patients, with a cytological adequacy of 69.0%. The number of adequate cytological results was 19 (65.5%) in group A and 21 (72.4%) in group B, and the diagnostic adequacy did not differ significantly between the two groups (Mann-Whitney test, p = 0.574). There was no statistically significant difference in the cytological adequacy of US-FNAC for cervical lymphadenopathy according using of 21 and 23 gauge needles.

  6. Axillary lymph node core biopsy for breast cancer metastases — How many needle passes are enough?

    International Nuclear Information System (INIS)

    Macaskill, E.J.; Purdie, C.A.; Jordan, L.B.; Mclean, D.; Whelehan, P.; Brown, D.C.; Evans, A.

    2012-01-01

    Aim: To determine the diagnostic yield of each of three core passes when sampling abnormal lymph nodes in patients presenting with breast cancer. Materials and methods: All patients suspected of having breast cancer had axillary ultrasound as part of initial assessment. Radiologically abnormal nodes (cortical thickness >2.3 mm or round shape) were biopsied with three passes of a 22 mm throw 14 G core biopsy needle and sent for histopathology in separate numbered pots. Data were collected prospectively, and analysis performed on the data of 55 consecutive patients who had positive nodes on at least one core biopsy needle pass. Results: Of 55 patients with a positive node on core biopsy, tumour was noted in all three cores taken in 39 (70.9%). Lymph node metastasis was detected in 45 (81.8%) first core biopsies. With the first two cores taken, positive results were detected in 53 of 55 cases (96.4%). In both cases where tumour was only found on a third core biopsy pass, no lymph node tissue was present in the first two biopsy passes. Conclusion: Two well-directed 14 G core biopsy samples from an abnormal axillary node are adequate for diagnosis of breast cancer metastasis.

  7. Guided fine needle aspiration cytology of retroperitoneal masses - Our experience

    Directory of Open Access Journals (Sweden)

    Mimi Gangopadhyay

    2011-01-01

    Full Text Available Background : Early pathological classification of retroperitoneal masses is important for pin-point diagnosis and timely management. Aims : This study was done to evaluate the usefulness and drawbacks of guided fine needle aspiration cytology (FNAC of retroperitoneal masses covering a period of two years with an intention to distinguish between neoplastic and non-neoplastic lesions and to correlate with histologic findings. Materials and Methods : FNAC was done under radiological guidance in all cases using long needle fitted with disposable syringe. Appropriate staining was done and cytology was correlated with histology which was taken as the gold standard for comparison. Results : Fifty-one patients who presented with retroperitoneal masses were studied. Forty-four lesions were malignant cytologically and 7 were inflammatory (tuberculous. According to radiological and cytologic findings, we classified our cases into four groups: renal tumors, retroperitoneal lymphadenopathy, germ cell tumors, soft tissue tumors. Except for cases of non-Hodgkin lymphoma (NHL and metastatic lesions, we had sensitivity and specificity of 100%. In NHL the sensitivity and specificity were both 50%. In cases of metastatic adenocarcinoma, the sensitivity and specificity were 84.6% and 81.8%, respectively. Conclusions : Ignoring the pitfalls, guided FNAC is still an inexpensive and reliable method of early diagnosis of retroperitoneal lesions.

  8. Bowel lesions: percutaneous US-guided 18-gauge needle biopsy--preliminary experience.

    Science.gov (United States)

    Tudor, G R; Rodgers, P M; West, K P

    1999-08-01

    Ultrasonography-guided percutaneous biopsy was performed with local anesthesia and an 18-gauge needle in 10 patients with bowel-wall lesions. All patients underwent clinical review within 1 month. Biopsy was diagnostic in all patients. There were no complications, and all patients tolerated the procedure well. The technique appears to be safe and had an excellent diagnostic yield in our series.

  9. Ultrasound-guided, minimally invasive, percutaneous needle puncture treatment for tennis elbow.

    Science.gov (United States)

    Zhu, Jiaan; Hu, Bing; Xing, Chunyan; Li, Jia

    2008-10-01

    This report evaluates the efficacy of percutaneous needle puncture under sonographic guidance in treating lateral epicondylitis (tennis-elbow). Ultrasound-guided percutaneous needle puncture was performed on 76 patients who presented with persistent elbow pain. Under a local anesthetic and sonographic guidance, a needle was advanced into the calcification foci and the calcifications were mechanically fragmented. This was followed by a local injection of 25 mg prednisone acetate and 1% lidocaine. If no calcification was found then multiple punctures were performed followed by local injection of 25 mg prednisone acetate and 1% lidocaine. A visual analog scale (VAS) was used to evaluate the degree of pain pre-and posttreatment at 1 week to 24 weeks. Elbow function improvement and degree of self-satisfaction were also evaluated. Of the 76 patients, 55% were rated with excellent treatment outcome, 32% good, 11% average, and 3% poor. From 3 weeks posttreatment, VAS scores were significantly reduced compared with the pretreatment score (Ptennis elbow. Sonography can be used to accurately identify the puncture location and monitor changes.

  10. Complication rates of CT-guided transthoracic lung biopsy: meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Heerink, W.J.; Vliegenthart, R. [University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, University of Groningen, Groningen (Netherlands); University Medical Center Groningen, Department of Radiology, University of Groningen, Groningen (Netherlands); Bock, G.H. de [University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, University of Groningen, Groningen (Netherlands); University Medical Center Groningen, Department of Epidemiology, University of Groningen, Groningen (Netherlands); Jonge, G.J. de [University Medical Center Groningen, Department of Radiology, University of Groningen, Groningen (Netherlands); Groen, H.J.M. [University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, University of Groningen, Groningen (Netherlands); University Medical Center Groningen, Department of Pulmonary Medicine, University of Groningen, Groningen (Netherlands); Oudkerk, M. [University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, University of Groningen, Groningen (Netherlands)

    2017-01-15

    To meta-analyze complication rate in computed tomography (CT)-guided transthoracic lung biopsy and associated risk factors. Four databases were searched from 1/2000 to 8/2015 for studies reporting complications in CT-guided lung biopsy. Overall and major complication rates were pooled and compared between core biopsy and fine needle aspiration (FNA) using the random-effects model. Risk factors for complications in core biopsy and FNA were identified in meta-regression analysis. For core biopsy, 32 articles (8,133 procedures) were included and for FNA, 17 (4,620 procedures). Pooled overall complication rates for core biopsy and FNA were 38.8 % (95 % CI: 34.3-43.5 %) and 24.0 % (95 % CI: 18.2-30.8 %), respectively. Major complication rates were 5.7 % (95 % CI: 4.4-7.4 %) and 4.4 % (95 % CI: 2.7-7.0 %), respectively. Overall complication rate was higher for core biopsy compared to FNA (p < 0.001). For FNA, larger needle diameter was a risk factor for overall complications, and increased traversed lung parenchyma and smaller lesion size were risk factors for major complications. For core biopsy, no significant risk factors were identified. In CT-guided lung biopsy, minor complications were common and occurred more often in core biopsy than FNA. Major complication rate was low. For FNA, smaller nodule diameter, larger needle diameter and increased traversed lung parenchyma were risk factors for complications. (orig.)

  11. Predicting factors for conversion from fluoroscopy guided Percutaneous transthoracic needle biopsy to cone-beam CT guided Percutaneous transthoracic needle biopsy

    International Nuclear Information System (INIS)

    Lee, Kang Ji; Han, Young Min; Jin, Gong Yong; Song, Ji Soo

    2015-01-01

    To evaluate the predicting factors for conversion from fluoroscopy guided percutaneous transthoracic needle biopsy (PTNB) to cone-beam CT guided PTNB. From January 2011 to December 2012, we retrospectively identified 38 patients who underwent cone-beam CT guided PTNB with solid pulmonary lesions, and 76 patients who underwent fluoroscopy guided PTNB were matched to the patients who underwent cone-beam CT guided PTNB for age, sex, and lesion location. We evaluated predicting factors such as, long-axis diameter, short-axis diameter, anterior-posterior diameter, and CT attenuation value of the solid pulmonary lesion affecting conversion from fluoroscopy guided PTNB to cone-beam CT guided PTNB. Pearson χ 2 test, Fisher exact test, and independent t test were used in statistical analyses; in addition, we also used receiver operating characteristics curve to find the proper cut-off values affecting the conversion to cone-beam CT guided PTNB. Short-axis, long-axis, anterior-posterior diameter and CT attenuation value of the solid pulmonary lesion in patients who underwent fluoroscopy guided PTNB were 2.70 ± 1.57 cm, 3.40 ± 1.92 cm, 3.06 ± 1.81 cm, and 35.67 ± 15.70 Hounsfield unit (HU), respectively. Short-axis, long-axis, anterior-posterior diameter and CT attenuation value of the solid pulmonary lesion in patients who underwent cone-beam CT guided PTNB were 1.60 ± 1.30 cm, 2.20 ± 1.45 cm, 1.91 ± 1.99 cm, and 18.32 ± 23.11 HU, respectively. Short-axis, long-axis, anterior-posterior diameter, and CT attenuation value showed a significantly different mean value between the 2 groups (p = 0.001, p < 0.001, p = 0.003, p < 0.001, respectively). Odd ratios of CT attenuation value and short-axis diameter of the solid pulmonary lesion were 0.952 and 0.618, respectively. Proper cut-off values affecting the conversion to cone-beam CT guided PTNB were 1.65 cm (sensitivity 68.4%, specificity 71.1%) in short-axis diameter and 29.50 HU (sensitivity 65.8%, specificity 65.8%) in

  12. Ultrasound Guided Needle Aspiration versus Surgical Drainage in the management of breast abscesses: a Ugandan experience

    Directory of Open Access Journals (Sweden)

    Chandika Alphonce B

    2012-01-01

    Full Text Available Abstract Background Despite breast abscess becoming less common in developed countries, it has remained one of the leading causes of morbidity in women in developing countries. A randomized controlled trial was conducted at Mulago hospital complex in Kampala Uganda to establish whether ultrasound guided needle aspiration is a feasible alternative treatment option for breast abscesses. Results A total of 65 females with breast abscess were analyzed, of these 33 patients were randomized into the ultrasound guided needle aspiration and 32 patients in the Incision and drainage arm. The mean age was 23.12, most of them were lactating (66.2%, primipararous (44.6% with peripheral abscesses (73.8% located in the upper lateral quadrant (56%.The mean breast size was 3.49 cm. The two groups were comparably in demographic characteristic and breast abscess size. Survival analysis showed no difference in breast abscess healing rate between the two groups (Log rank 0.24 df 1 and P = 0.63. Incision and drainage was found to be more costly than ultrasound guided aspiration (cost effective ratio of 2.85. Conclusion Ultrasound guided needle aspiration is therefore a feasible and cost effective treatment option for both lactating and non lactating breast abscesses with a diameter up to 5 cm by ultrasound in an immune competent patient

  13. Imaging-guided percutaneous needle biopsy for infectious spondylitis: Factors affecting culture positivity

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Si Yoon; Kwon, Jong Won [Dept. of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2015-11-15

    To evaluate the variable factors affecting the results of percutaneous needle biopsies for infectious spondylitis. In all, 249 patients who underwent both MRI and percutaneous needle biopsies due to a suspicion of infectious spondylitis were evaluated with respect to the following factors: the usage of antibiotics before the procedure, the location of the biopsy, the guiding equipment used, the experience level of the operators, and the number of biopsies performed. The positivity of culture in cases of treated with antibiotics (16.3%) before the biopsy was lower than in the untreated cases (30.5%) (p = 0.004). Biopsies performed at the abscess (43.5%) and with fluoroscopic guidance (27.8%) showed higher culture positivity as well. The experience level of the operators and the number of biopsies had no effect on culture positivity. The usage of antibiotics before the biopsy, the biopsy's location, and the guiding equipment used affect the culture positivity, while the experience levels of the operators and the number of biopsies do not have an effect.

  14. Imaging-guided percutaneous needle biopsy for infectious spondylitis: Factors affecting culture positivity

    International Nuclear Information System (INIS)

    Sung, Si Yoon; Kwon, Jong Won

    2015-01-01

    To evaluate the variable factors affecting the results of percutaneous needle biopsies for infectious spondylitis. In all, 249 patients who underwent both MRI and percutaneous needle biopsies due to a suspicion of infectious spondylitis were evaluated with respect to the following factors: the usage of antibiotics before the procedure, the location of the biopsy, the guiding equipment used, the experience level of the operators, and the number of biopsies performed. The positivity of culture in cases of treated with antibiotics (16.3%) before the biopsy was lower than in the untreated cases (30.5%) (p = 0.004). Biopsies performed at the abscess (43.5%) and with fluoroscopic guidance (27.8%) showed higher culture positivity as well. The experience level of the operators and the number of biopsies had no effect on culture positivity. The usage of antibiotics before the biopsy, the biopsy's location, and the guiding equipment used affect the culture positivity, while the experience levels of the operators and the number of biopsies do not have an effect

  15. The diagnostic value of ultrasound-guided fine-needle aspiration biopsy in breast masses

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Nam Hee; Lim, Hyun Yang; Park, Noh Kyong; Tae, Seok; Shin, Kyung Ja; Lee, Sang Chun [Seoul Red Cross Hospital, Seoul (Korea, Republic of)

    1993-05-15

    Real-time ultrasound-guided fine-needle aspiration biopsy in 137 solid breast masses was performed. Sonographic findings were categorized into three groups and aspirates were categorized into three cytologic groups. The cytologic results was reported benign masses (cytologic group 1) in 71 cases (52%). malignant masses (cytologic group 2 and 3) in 44 cases (32%) and insufficient specimens in 22 case (16%). Insufficient specimens were treated as benign masses. Excisional biopsy in 44 malignant masses and 3 benign masses according to cytologic results, clinical findings and follow up study was performed. The result was reported 41 malignant masses and 6 benign masses. Based on cytologic criteria, sensitivity for detection of malignancy was 93% and specificity was 94%. In conclusion, the high specificity provided by ultrasound-guided fine-needle aspiration biopsy could markedly reduce unnecessary surgical excisions for benign masses and it should be routinely performed, since it can give physical and emotional benefits to patients and lead to earlier and cost effective diagnosis of breast cancer.

  16. The diagnostic value of ultrasound-guided fine-needle aspiration biopsy in breast masses

    International Nuclear Information System (INIS)

    Lee, Nam Hee; Lim, Hyun Yang; Park, Noh Kyong; Tae, Seok; Shin, Kyung Ja; Lee, Sang Chun

    1993-01-01

    Real-time ultrasound-guided fine-needle aspiration biopsy in 137 solid breast masses was performed. Sonographic findings were categorized into three groups and aspirates were categorized into three cytologic groups. The cytologic results was reported benign masses (cytologic group 1) in 71 cases (52%). malignant masses (cytologic group 2 and 3) in 44 cases (32%) and insufficient specimens in 22 case (16%). Insufficient specimens were treated as benign masses. Excisional biopsy in 44 malignant masses and 3 benign masses according to cytologic results, clinical findings and follow up study was performed. The result was reported 41 malignant masses and 6 benign masses. Based on cytologic criteria, sensitivity for detection of malignancy was 93% and specificity was 94%. In conclusion, the high specificity provided by ultrasound-guided fine-needle aspiration biopsy could markedly reduce unnecessary surgical excisions for benign masses and it should be routinely performed, since it can give physical and emotional benefits to patients and lead to earlier and cost effective diagnosis of breast cancer

  17. Needle localization using a moving stylet/catheter in ultrasound-guided regional anesthesia: a feasibility study

    Science.gov (United States)

    Beigi, Parmida; Rohling, Robert

    2014-03-01

    Despite the wide range and long history of ultrasound guided needle insertions, an unresolved issue in many cases is clear needle visibility. A well-known ad hoc technique to detect the needle is to move the stylet and look for changes in the needle appearance. We present a new method to automatically locate a moving stylet/catheter within a stationary cannula using motion detection. We then use this information to detect the needle trajectory and the tip. The differences between the current frame and the previous frame are detected and localized, to minimize the influence of tissue global motions. A polynomial fit based on the detected needle axis determines the estimated stylet shaft trajectory, and the extent of the differences along the needle axis represents the tip. Over a few periodic movements of the stylet including its full insertion into the cannula to the tip, a combination of polynomial fits determines the needle trajectory and the last detected point represents the needle tip. Experiments are conducted in water bath and bovine muscle tissue for several stylet/catheter materials. Results show that a plastic stylet has the best needle shaft and tip localization accuracy in the water bath with RMSE = 0:16 mm and RMSE = 0:51 mm, respectively. In the bovine tissue, the needle tip was best localized with the plastic catheter with RMSE = 0:33 mm. The stylet tip localization was most accurate with the steel stylet, with RMSE = 2:81 mm and the shaft was best localized with the plastic catheter, with RMSE = 0:32 mm.

  18. Diagnostic accuracy and safety of CT-guided fine needle aspiration biopsy in cavitary pulmonary lesions

    Energy Technology Data Exchange (ETDEWEB)

    Zhuang, Yi-Ping, E-mail: yipingzhuang2010@sina.com [Department of Radiology, Jiangsu Cancer Institute and Hospital, No. 42 Baiziting Road, Nanjing 210009, Jiangsu (China); Wang, Hai-Yan, E-mail: mycherishgirl@sohu.com [Department of Radiology, Jiangsu Cancer Institute and Hospital, No. 42 Baiziting Road, Nanjing 210009, Jiangsu (China); Zhang, Jin, E-mail: yari_zj@hotmail.com [Department of Radiology, Jiangsu Cancer Institute and Hospital, No. 42 Baiziting Road, Nanjing 210009, Jiangsu (China); Feng, Yong, E-mail: fengyong119@sohu.com [Department of Radiology, Jiangsu Cancer Institute and Hospital, No. 42 Baiziting Road, Nanjing 210009, Jiangsu (China); Zhang, Lei, E-mail: motozl163@163.com [Department of Radiology, Jiangsu Cancer Institute and Hospital, No. 42 Baiziting Road, Nanjing 210009, Jiangsu (China)

    2013-01-15

    Objective: CT-guided transthoracic biopsy is a well-established method in the cytologic or histologic diagnosis of pulmonary lesions. The knowledge of its diagnostic performance and complications for cavitary pulmonary lesions is limited. The purpose of this study was to determine the diagnostic accuracy and safety of CT-guided fine needle aspiration biopsy (FNAB) in cavitary pulmonary lesions. Materials and methods: 102 consecutive patients with pulmonary cavitary lesions received CT-guided FNAB with use of an 18-gauge (n = 35) or 20-gauge (n = 67) Chiba for histology diagnosis. The sensitivity, specificity, and diagnostic accuracy of FNAB were calculated as compared with the final diagnosis. Complications associated with FNAB were observed. The diagnostic accuracy and complications were compared between patients with different lesion sizes and different cavity wall thickness. Results: The overall sensitivity, specificity, and accuracy of FNAB were 96.3%, 98.0%, and 96.1%, respectively. The sensitivity, specificity, and diagnosis accuracy in different lesion size (<2 cm vs ≥2 cm), or different cavity wall thickness (<5 mm vs ≥5 mm) were not different (P > 0.05; 0.235). More nondiagnostic sample was found in wall thickness <5 mm lesions (P = 0.017). Associated complications included pneumothorax in 9 (8.8%) patients and alveolar hemorrhage in 14 patients (13.7%) and hemoptysis in 1 patient (1%). No different rate of complications was found with regard to lesion size, wall thickness, length of the needle path and needle size (P > 0.05). Conclusion: CT-guided FNAB can be effectively ad safely used for patients with pulmonary cavitary lesions.

  19. The effects of hypnotherapy during transrectal ultrasound-guided prostate needle biopsy for pain and anxiety.

    Science.gov (United States)

    Hızlı, Fatih; Özcan, Osman; Selvi, İsmail; Eraslan, Pınar; Köşüş, Aydın; Baş, Okan; Yıkılmaz, Taha Numan; Güven, Oğuz; Başar, Halil

    2015-11-01

    Several studies evaluating the tolerance of transrectal ultrasound (TRUS)-guided needle biopsies showed that moderate-to-severe pain was associated with the procedure. Additionally, prebiopsy anxiety or rebiopsy as a result of a prior biopsy procedure is mentioned as factors predisposing to higher pain intensity. Thus, in this study, we investigated the effects of hypnotherapy during transrectal ultrasound-guided prostate needle biopsy for pain and anxiety. Sixty-four patients presenting for TRUS-guided prostate needle biopsy were randomly assigned to receive either 10-min presurgery hypnosis session (n = 32, mean age 63.5 ± 6.1, p = 0.289) or a presurgery control session (n = 32, mean age 61.8 ± 6.8, p = 0.289). The hypnosis session involved suggestions for increased relaxation and decreased anxiety. Presurgery pain and anxiety were measured using visual analog scales (VAS), Beck Anxiety Inventory (BAI), and Hamilton Anxiety Scale (HAS), respectively. In our statistics, p < 0.05 was considered statistically significant. Postintervention, and before surgery, patients in the hypnosis group had significantly lower mean values for presurgery VAS [mean 1 (0-8); p = 0.011], BAI (6.0 vs 2.0; p < 0.001), and HAS (11.0 vs 6.0; p < 0.001). The study results indicate that a brief presurgery hypnosis intervention can be an effective means of controlling presurgical anxiety, and therefore pain, in patients awaiting diagnostic prostate cancer surgery.

  20. CT-guided needle biopsy of lung lesions: A survey of severe complication based on 9783 biopsies in Japan

    International Nuclear Information System (INIS)

    Tomiyama, Noriyuki; Yasuhara, Yoshifumi; Nakajima, Yasuo; Adachi, Shuji; Arai, Yasuaki; Kusumoto, Masahiko; Eguchi, Kenji; Kuriyama, Keiko; Sakai, Fumikazu; Noguchi, Masayuki; Murata, Kiyoshi; Murayama, Sadayuki; Mochizuki, Teruhito; Mori, Kiyoshi; Yamada, Kozo

    2006-01-01

    Purpose: The aim of our study was to update the rate of severe complications following CT-guided needle biopsy in Japan via a mailed survey. Materials and methods: Postal questionnaires regarding CT-guided needle biopsy were sent out to multiple hospitals in Japan. The questions regarded: the total number and duration of CT-guided lung biopsies performed at each hospital, and the complication rates and numbers of pneumothorax, hemothorax, air embolism, tumor seeding, tension pneumothorax and other rare complications. Each severe complication was followed with additional questions. Results: Data from 9783 biopsies was collected from 124 centers. Pneumothorax was the most common complication, and occurred in 2412 (35%) of 6881 cases. A total of 39 (35%) hospitals reported 74 (0.75%) cases with severe complications. There were six cases (0.061%) with air embolism, six cases (0.061%) with tumor seeding at the site of the biopsy route, 10 cases (0.10%) with tension pneumothorax, six cases (0.061%) with severe pulmonary hemorrhage or hemoptysis, nine cases (0.092%) with hemothorax, and 27 cases (0.26%) with others, including heart arrest, shock, and respiratory arrest. From a total of 62 patients with severe complications, 54 patients (0.55%) recovered without sequela, however one patient (0.01%) recovered with hemiplegia due to cerebral infarction, and the remaining seven patients (0.07%) died. Conclusions: This is the first national study documenting severe complications with respect to CT-guided needle biopsy in Japan. The complication rate in Japan is comparable to internationally published figures. We believe this data will improve both clinicians as well as patients understanding of the risk versus benefit of CT-guided needle biopsy, resulting better decisions

  1. Concordance between fine-needle aspiration and core biopsies for osseous lesions by lesion imaging appearance and CT attenuation.

    Science.gov (United States)

    Li, John; Weissberg, Zoe; Bevilacqua, Thomas A; Yu, Gordon; Weber, Kristy; Sebro, Ronnie

    2018-04-01

    To compare the concordance between fine-needle aspiration and core biopsies for osseous lesions by lesion imaging appearance and CT attenuation. Retrospective review of 215 FNAs of osseous lesions performed in conjunction with core biopsy at our institution over a 6-year period (2011-2016). FNAs were interpreted independently of core biopsies. We assessed if FNA in conjunction with core biopsy increased diagnostic accuracy compared to core biopsy alone. We also calculated the concordance between FNA and core biopsy by lesion appearance, lesion CT attenuation, lesion histology, lesion location and FNA needle gauge size. Core biopsy alone provided the diagnosis in 207/215 cases (96.3%), however, the FNA provided the diagnosis in the remaining 8/215 cases (3.7%) where the core biopsy was non-diagnostic. There were 154 (71.6%) lytic lesions, 21 (9.8%) blastic lesions, 25 (11.6%) mixed lytic and blastic lesions and 15 (7.0%) lesions that were neither lytic nor blastic. The concordance between FNA and core biopsy for lytic osseous lesions (136/154 cases, 88.3%) was statistically significantly higher than that for blastic osseous lesions (13/21 cases, 61.9%) [P = 4.2 × 10 -3 ; 95% CI (0.02, 0.50)]. The concordance between FNA and core biopsy was higher for low-attenuation- (110/126) than high-attenuation (58/77) lesions (P = 0.028). The concordance between FNA and core biopsy was also higher for metastases (102/119 cases, 85.7%) than non-metastases (78/96, 81.3%) [P = 0.487; 95% CI (- 0.15, 0.065)]. There was no difference in the rate of concordance between FNA and core biopsy by lesion location or FNA needle gauge size (P > 0.05). FNA with core biopsy increases diagnostic rate compared to core biopsy alone or FNA alone. The concordance between FNA and core biopsy is higher for lytic lesions than for blastic lesions; and higher for low-attenuation lesions than for high-attenuation lesions.

  2. Radiation resistivity of pure-silica core image guide

    International Nuclear Information System (INIS)

    Hayami, H.; Ishitani, T.; Kishihara, O.; Suzuki, K.

    1988-01-01

    Radiation resistivity of pure-silica core image guides were investigated in terms of incremental spectral loss and quality of pictures transmitted through the image guides. Radiation-induced spectral losses were measured so as to clarify the dependences of radiation resistivity on such parameters as core materials (OH and Cl contents), picture element dimensions, (core packing density and cladding thickness), number of picture elements and drawing conditions. As the results, an image guide with OH-and Cl-free pure-silica core, 30-45% in core packing density, and 1.8 ∼ 2.2 μm in cladding thickness showed the lowest loss. The parameters to design this image guide were almost the same as those to obtain a image guide with good picture quality. Radiation resistivity of the image guide was not dependent on drawing conditions and number of picture elements, indicating that the image guide has large allowable in production conditions and that reliable quality is constantly obtained in production. Radiation resistivity under high total doses was evaluated using the image guide with the lowest radiation-induced loss. Maximum usable lengths of the image guide for practical use under specific high total doses and maximum allowable total doses for the image guide in specific lengths were extrapolated. Picture quality in terms of radiation-induced degradation in color fidelity in the pictures transmitted through image guides was quantitatively evaluated in the chromaticity diagram based on the CIE standard colorimetric system and in the color specification charts according to three attributes of colors. The image guide with the least spectral incremental loss gives the least radiation-induced degradation in color fidelity in the pictures as well. (author)

  3. C-arm cone beam computed tomography needle path overlay for fluoroscopic guided vertebroplasty.

    Science.gov (United States)

    Tam, Alda L; Mohamed, Ashraf; Pfister, Marcus; Chinndurai, Ponraj; Rohm, Esther; Hall, Andrew F; Wallace, Michael J

    2010-05-01

    /3 border of the vertebral body was measured, and 75% when distance from target to needle tip was measured. There were no major complications. Minor complications consisted of 3 cases (25%) of cement extravasation. C-arm CBCT with needle path overlay for fluoroscopic guided vertebroplasty is feasible and allows for reliable unilateral therapy of both lumbar and thoracic vertebral bodies. Extrapedicular approaches were performed safely and with good accuracy of reaching the targets.

  4. Fluoroscopically Guided Extraforaminal Cervical Nerve Root Blocks: Analysis of Epidural Flow of the Injectate with Respect to Needle Tip Position

    Science.gov (United States)

    Shipley, Kyle; Riew, K. Daniel; Gilula, Louis A.

    2013-01-01

    Study Design Retrospective evaluation of consecutively performed fluoroscopically guided cervical nerve root blocks. Objective To describe the incidence of injectate central epidural flow with respect to needle tip position during fluoroscopically guided extraforaminal cervical nerve root blocks (ECNRBs). Methods Between February 19, 2003 and June 11, 2003, 132 consecutive fluoroscopically guided ECNRBs performed with contrast media in the final injected material (injectate) were reviewed on 95 patients with average of 1.3 injections per patient. Fluoroscopic spot images documenting the procedure were obtained as part of standard quality assurance. An independent observer not directly involved in the procedures retrospectively reviewed the images, and the data were placed into a database. Image review was performed to determine optimal needle tip positioning for injectate epidural flow. Results Central epidural injectate flow was obtained in only 28.9% of injections with the needle tip lateral to midline of the lateral mass (zone 2). 83.8% of injectate went into epidural space when the needle tip was medial to midline of the lateral mass (zone 3). 100% of injectate flowed epidurally when the needle tip was medial to or at the medial cortex of the lateral mass (zone 4). There was no statistically significant difference with regards to central epidural flow and the needle tip position on lateral view. Conclusion To ensure central epidural flow with ECNRBs one must be prepared to pass the needle tip medial to midplane of the lateral mass or to medial cortex of the lateral mass. Approximately 16% of ECNRBs with needle tip medial to midline of the lateral mass did not flow into epidural space. One cannot claim a nerve block is an epidural block unless epidural flow of injectate is observed. PMID:24494176

  5. Comparing Effective Doses During Image-Guided Core Needle Biopsies with Computed Tomography Versus C-Arm Cone Beam CT Using Adult and Pediatric Phantoms.

    Science.gov (United States)

    Ben-Shlomo, A; Cohen, D; Bruckheimer, E; Bachar, G N; Konstantinovsky, R; Birk, E; Atar, E

    2016-05-01

    To compare the effective doses of needle biopsies based on dose measurements and simulations using adult and pediatric phantoms, between cone beam c-arm CT (CBCT) and CT. Effective doses were calculated and compared based on measurements and Monte Carlo simulations of CT- and CBCT-guided biopsy procedures of the lungs, liver, and kidney using pediatric and adult phantoms. The effective doses for pediatric and adult phantoms, using our standard protocols for upper, middle and lower lungs, liver, and kidney biopsies, were significantly lower under CBCT guidance than CT. The average effective dose for a 5-year old for these five biopsies was 0.36 ± 0.05 mSv with the standard CBCT exposure protocols and 2.13 ± 0.26 mSv with CT. The adult average effective dose for the five biopsies was 1.63 ± 0.22 mSv with the standard CBCT protocols and 8.22 ± 1.02 mSv using CT. The CT effective dose was higher than CBCT protocols for child and adult phantoms by 803 and 590% for upper lung, 639 and 525% for mid-lung, and 461 and 251% for lower lung, respectively. Similarly, the effective dose was higher by 691 and 762% for liver and 513 and 608% for kidney biopsies. Based on measurements and simulations with pediatric and adult phantoms, radiation effective doses during image-guided needle biopsies of the lung, liver, and kidney are significantly lower with CBCT than with CT.

  6. Image-guided automated needle biopsy of 106 thoracic lesions: a retrospective review of diagnostic accuracy and complication rates

    International Nuclear Information System (INIS)

    Connor, S.; Dyer, J.; Guest, P.

    2000-01-01

    We reviewed the diagnostic accuracy and complication rates of transthoracic needle biopsy (TNB) with an automated 18-gauge core biopsy needle and gun, using either fluoroscopic or CT guidance. One hundred six lesions were biopsied in 103 patients between 1992 and 1998. Hard-copy images, imaging reports, pathology reports and clinical notes were reviewed. In 3 patients it was not possible to establish the lesion as either malignant or benign from the available follow-up, so these were removed from the analysis of diagnostic accuracy. Adequate samples for histological diagnosis were obtained in 104 of 106 (98 %) biopsies. There were 75 of 85 (88 %) true-positive core biopsies for malignant lesions and a specific cell type was identified in 70 of 85 (82 %) cases. A specific histological diagnosis was obtained in 12 of 18 (66 %) biopsies. There was a 19 % rate of pneumothorax with only 2.4 % requiring drainage. Minor haemoptysis occurred in 3.8 % of procedures. The TNB technique with an automated core biopsy needle provides a high level of diagnostic accuracy, effectively distinguishes cell type in malignancy and provides a definite diagnosis in benign disease more frequently than fine needle aspiration (FNA). There is no increased complication rate compared with FNA. (orig.)

  7. Image guided versus palpation guided core needle biopsy of palpable breast masses: a prospective study

    Directory of Open Access Journals (Sweden)

    Smriti Hari

    2016-01-01

    Interpretation & conclusions: Our results showed that in palpable breast masses, image guided biopsy was superior to palpation guided biopsy in terms of sensitivity, false negative rate and repeat biopsy rates.

  8. Long term clinical follow-up of atypical ductal hyperplasia and lobular carcinoma in situ in breast core needle biopsies.

    Science.gov (United States)

    Renshaw, Andrew A; Gould, Edwin W

    2016-01-01

    Atypical ductal hyperplasia (ADH) and lobular carcinoma in situ (LCIS) may be associated with a relatively high incidence of invasive carcinoma and ductal carcinoma in situ (DCIS) on immediate excision when found on core needle biopsy of the breast. However, the long term significance of ADH and LCIS in a breast core needle biopsy is not as well characterised. We reviewed the results of all breast core needle biopsies with a diagnosis of ADH or LCIS and immediate excision from the years 2000-2004, and correlated the results with long term clinical follow-up. Of 175 biopsies with ADH, 53 (30.3%) had carcinoma (8 invasive, and 45 DCIS) at the time of immediate re-excision. Of 69 biopsies with LCIS, three (4.3%) had carcinoma (2 invasive, and 1 DCIS) at the time of immediate re-excision. A total of 14 (11.5%) patients with ADH and benign re-excisions developed invasive carcinoma (12) or DCIS (2) on follow-up. A total of 17 (25.8%) patients with LCIS and benign re-excisions developed invasive carcinoma (13) or DCIS (4) on follow-up. The risk of invasive carcinoma or DCIS on immediate re-excision was significantly higher for women with ADH than LCIS (pfibrocystic changes (FCC) on core needle biopsy, the risk of developing invasive carcinoma or DCIS was significantly higher for women with ADH and benign initial re-excisions (95% CI 1.092-7.297, p=0.03), and women with LCIS and benign re-excisions (95% CI 3.028-18.657, p<0.001). Overall, 67/175 (38.3%) women with ADH and 20/69 (29.0%) women with LCIS on core needle biopsy either had carcinoma at the time of the biopsy or later developed carcinoma. Significantly more women with LCIS developed invasive carcinoma or DCIS than women with ADH on long term follow-up. The relative risk for ADH and LCIS on core biopsy with a negative excision compared with FCC was similar to that reported in the literature (ADH 1-7×, LCIS 3-19×). Copyright © 2015 The Royal College of Pathologists of Australasia. Published by Elsevier B.V. All

  9. Fiber Bragg gratings-based sensing for real-time needle tracking during MR-guided brachytherapy

    NARCIS (Netherlands)

    Borot, Maxence; Denis de Senneville, Baudouin; Maenhout, Metha; Lagendijk, JJW; van Vulpen, Marco; Hautvast, Gilion; Binnekamp, Dirk; Moerland, Rien

    2016-01-01

    PURPOSE: The development of MR-guided high dose rate (HDR) brachytherapy is under investigation due to the excellent tumor and organs at risk visualization of MRI. However, MR-based localization of needles (including catheters or tubes) has inherently a low update rate and the required image

  10. CT guided fine needle aspiration biopsy of biliopancreatic lesions

    International Nuclear Information System (INIS)

    Geng, Jia-Zheng; Qin, Pan-Rui; Hui, Liu-De; Po, Pei-Dong

    1987-01-01

    CT guided percutaneous fine needle aspiration biopsy was performed on 30 patients with pancreatic and periampullary neoplasms, in the Department of Surgery, China-Japan Friendship Hospital, between March 1985 and January 1986. We obtained positive cytodiagnosis from all cases of carcinoma of the pancreatic head (9 cases), body and tail (4 cases), and ampullary carcinomas (5 cases) (100 per cent). In 2 of 3 duodenal carcinomas (66.6 per cent), and 6 of 7 distal common duct carcinomas (86 per cent), a positive cytodiagnosis was also obtained. On the other hand, 2 cases of pancreatitis both gave a negative cytodiagnosis, i.e. no false positives were obtained. Out of the 30 cases who underwent CT guided biopsy, a correct diagnosis was obtained in 28, i.e. a diagnostic accuracy of 93.3 per cent. The cytodiagnosis of the other two cases was either suspicious or false negative. There have been no clinical complications noted. (author)

  11. Patient-specific core decompression surgery for early-stage ischemic necrosis of the femoral head.

    Directory of Open Access Journals (Sweden)

    Wei Wang

    Full Text Available Core decompression is an efficient treatment for early stage ischemic necrosis of the femoral head. In conventional procedures, the pre-operative X-ray only shows one plane of the ischemic area, which often results in inaccurate drilling. This paper introduces a new method that uses computer-assisted technology and rapid prototyping to enhance drilling accuracy during core decompression surgeries and presents a validation study of cadaveric tests.Twelve cadaveric human femurs were used to simulate early-stage ischemic necrosis. The core decompression target at the anterolateral femoral head was simulated using an embedded glass ball (target. Three positioning Kirschner wires were drilled into the top and bottom of the large rotor. The specimen was then subjected to computed tomography (CT. A CT image of the specimen was imported into the Mimics software to construct a three-dimensional model including the target. The best core decompression channel was then designed using the 3D model. A navigational template for the specimen was designed using the Pro/E software and manufactured by rapid prototyping technology to guide the drilling channel. The specimen-specific navigation template was installed on the specimen using positioning Kirschner wires. Drilling was performed using a guide needle through the guiding hole on the templates. The distance between the end point of the guide needle and the target was measured to validate the patient-specific surgical accuracy.The average distance between the tip of the guide needle drilled through the guiding template and the target was 1.92±0.071 mm.Core decompression using a computer-rapid prototyping template is a reliable and accurate technique that could provide a new method of precision decompression for early-stage ischemic necrosis.

  12. Evaluation of a novel Seldinger-needle for computed tomography guided interventions: initial experiences; Evaluierung einer neuen Seldinger-Nadel fuer computertomografisch gesteuerte Interventionen: Erste Erfahrungen

    Energy Technology Data Exchange (ETDEWEB)

    Plumhans, C.; Mahnken, A.; Iwa, R.; Behrendt, F.F.; Sebastian, K.; Guenther, R.W.; Honnef, D. [Universitaetsklinikum RWTH Aachen (Germany). Klinik fuer Radiologische Diagnostik

    2009-02-15

    To evaluate a new Seldinger puncture device for computed tomography-guided interventions under difficult conditions, to analyze applicability, and to investigate assets and drawbacks. From November 2007 to March 2008, we performed CT-guided interventions in 16 patients (7 women, 9 men; mean age 62 years old) using a new 20G-Seldinger needle (Sika-Med, Wiehl, Germany). This novel needle serves as a guide for many different interventional devices due to a guide wire welded on the proximal needle end. It allows continuous application of anesthesia via four tiny holes at the distal needle end until the region of interest is reached. Each intervention was subject to difficult interventional conditions. The indications for intervention were drainage (n = 7), Trucut biopsy of tumor (n = 8) and radiofrequency ablation (n = 1). Handling, success, advantages, drawbacks, complications and patient tolerance were noted after each procedure. A pain scale from 1 - 10 was used to grade the pain level during the intervention. All interventions were performed successfully and no severe complications were observed. Patient tolerance was very good resulting in a mean pain score of 2 {+-} 1. Regions with dangerous and difficult access were successfully reached with the new Seldinger needle in 15 of 16 cases by dilatation of the puncture tract and continuous administration of local anesthesia via the system. Furthermore, different devices such as Trucut systems and a drainage catheter were able to be inserted without complication via the needle. With a proximal removable luer-lock connection, liquid material was able to be aspirated in six cases. Under difficult interventional conditions, the use of a Seldinger needle as a reliable technique for CT-guided interventions can provide a safe and successful procedure. (orig.)

  13. CT-guided percutaneous injection of the fibrin glue by 'double needle' technique for the treatment of sacral cysts

    International Nuclear Information System (INIS)

    Wang Ganggang; Chen Long; Yang Chao; Ni Caifang

    2013-01-01

    Objective: To analyze the efficacy and safety of CT-guided percutaneous injection of the fibrin glue by 'double needle' technique to treat sacral cyst. Methods: Clinical data of 20 cases with 'double-needle' injection of fibrin glue technology to treat sacral cyst were retrospectively analyzed. All patients had varying degrees of sacral nerve root compression symptoms. The treatment for sacral cyst was carried out after clear diagnosis was made. On the basis of CT-guided percutaneous injection of fibrin glue, the improved CT-guided percutaneous injection of fibrin glue by 'double-needle' technique was used to treat these patients. The average dose of fibrin glue was (5.9 ± 2.4) ml. The clinical results of improvement as to pain and neurological function were evaluated after follow-up of an average of 17 months. The assessment criteria were as follows: excellent, complete resolution of signs and symptoms, with the patient returning to his or her regular employment and no recurrence of cysts during 1 year of follow-up, good, symptoms and signs in the legs and perineal region resolved but with persistent pain in the lumbosacral region, which did not interfere with the patient's regular work (the cysts did not recur for 6 months during follow-up), fair, no improvement in clinical symptoms, but a decrease in cyst size on the imaging study, poor, no improvement in clinical symptoms and no observed changes in cyst size in imaging studies or recurrence. Results: Most patients experienced some degree of pain relief and functional improvement after fibrin glue therapy, with most experiencing complete or marked resolution of clinical symptoms. Nine patients reported excellent recovery, 8 reported good recovery, 2 reported fair recovery, and 1 reported poor recovery. The overall percentage of positive outcomes (excellent and good recovery) was 85%. No serious postoperative complications were discovered. Conclusions: CT guided percutaneous injection of the fibrin glue by

  14. Results and complications of CT-guided transthoracic fine-needle aspiration biopsy of pulmonary lesions

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Cristiano Dias de; Nunes, Rodolfo Acatauassu; Saito, Eduardo Haruo; Higa, Claudio; Cardona, Zanier Jose Fernando; Santos, Denise Barbosa dos, E-mail: cristianodiaslima@gmail.co [Hospital Universitario Pedro Ernesto (HUPE/UERJ), Rio de Janeiro, RJ (Brazil). Dept. Cirurgia Toracica

    2011-03-15

    Objective: to analyze the cytological findings of CT-guided percutaneous fine-needle aspiration biopsies of the lung, to demonstrate the diagnostic feasibility of the method in the investigation of pulmonary lesions, and to determine the complications of the procedure, evaluating its safety. Methods: a retrospective analysis of 89 patients with various types of pulmonary lesions who underwent 97 procedures over a period of five years. The patients were divided into groups regarding the indication for the procedure: suspicion of primary lung cancer (stages IIIB or IV); suspicion of lung cancer (stages I, II, or IIIA) and clinical contraindications for surgery; suspicion of pulmonary metastasis from other organs; and pulmonary lesions with benign radiological aspect. All of the procedures were performed with 25-gauge needles and were guided by spiral CT. The final diagnosis was confirmed by surgical biopsy and clinical/oncological follow-up. For the analysis of complications, the total number of procedures was considered. Results: the main indication for the procedure was suspicion of advanced stage primary lung cancer. The accuracy of the method for malignant lesions was 91.5%. The lesion was confirmed as cancer in 73% of the patients. The major complication was pneumothorax (27.8%), which required chest tube drainage in 12.4% of the procedures. Conclusions: the principal indication for CT-guided fine-needle biopsy was suspicion of primary lung cancer in patients who were not surgical candidates. The procedure has high diagnostic feasibility for malignant pulmonary diseases. The most prevalent complication was pneumothorax. However, in most cases, chest tube drainage was unnecessary. No deaths were related to the procedure. (author)

  15. Carbon fibre and nitinol needles for MRI-guided interventions: First in vitro and in vivo application

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, Christoph, E-mail: Christoph.thomas@med.uni-tuebingen.de [Department of Diagnostic and Interventional Radiology, University of Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen (Germany); Wojtczyk, Hanne [Section of Experimental Radiology, University of Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen (Germany); Rempp, Hansjoerg; Clasen, Stephan; Horger, Marius [Department of Diagnostic and Interventional Radiology, University of Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen (Germany); Lassberg, Christoph von [Department of Sports Medicine, University of Tuebingen, Silcherstrasse 5, 72076 Tuebingen (Germany); Fritz, Jan [Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, 600 North Wolfe Street, Baltimore, MD 21287 (United States); Claussen, Claus D. [Department of Diagnostic and Interventional Radiology, University of Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen (Germany); Pereira, Philippe L. [Department of Radiology, Minimally Invasive Therapies and Nuclearmedicine, SLK-Kliniken Heilbronn GmbH, Am Gesundbrunnen 20-26, 74078 Heilbronn (Germany)

    2011-09-15

    Objective: To assess the artefact properties of a MR-compatible carbon fibre needle with a nitinol mandrin in vitro and to report first clinical experiences. Materials and methods: In vitro, the carbon fibre/nitinol needle was imaged at different angles against the main magnetic field (1.5 T open bore magnet). A gradient echo MR fluoroscopy sequence (GRE: TR 9.3 ms, TE 3.12 ms, bandwidth 200 Hz/pixel, flip-angle 12{sup o}) and a fast turbo spin echo sequence (FSE: TR 412 ms, TE 9.7 ms, bandwidth 200 Hz/pixel, flip-angle 150{sup o}) were used. Artefact width, needle intensity contrast and needle tip location errors were assessed. In vivo, lumbar periradicular corticosteroid injections and one sclerotherapy were performed with carbon fibre needles (10 procedures) and with titanium alloy needles (2 procedures). The artefact sizes and contrasts were measured. Results: In vitro, artefact diameters of the carbon fibre needle ranged from 3.3 to 4.6 mm, contrasts from 0.11 to 0.52, with larger artefact contrasts and widths with the GRE sequence. Needle tip location errors of -2.1 to -2.8 mm were observed. Decreasing angles to the main field lead to smaller artefacts. In vivo, the carbon fibre/nitinol needle produced smaller artefacts (mean width FSE/GRE: 2.8 mm/4.6 mm) with lower contrast (0.30-0.42) than the titanium alloy needle (mean width FSE/GRE: 4.1 mm/7.5 mm, contrast 0.60-0.73). Conclusions: The carbon fibre/nitinol needle is useful for performing MR-guided interventions at 1.5 T, producing more subtle artefacts than a titanium alloy needle, but with an incomplete depiction and thus inaccurate localization of the needle tip.

  16. Computer-Aided Design/Computer-Assisted Manufacture-Derived Needle Guide for Injection of Botulinum Toxin into the Lateral Pterygoid Muscle in Patients with Oromandibular Dystonia.

    Science.gov (United States)

    Yoshida, Kazuya

    2018-01-01

    To evaluate the effectiveness and safety of botulinum toxin administration into the inferior head of the lateral pterygoid muscle of patients with jaw opening dystonia by using a computer-aided design/computer-assisted manufacture (CAD/CAM)-derived needle guide. A total of 17 patients with jaw opening dystonia were enrolled. After the patient's computed tomography (CT) scan was imported and fused with a scan of a plaster cast model of the maxilla, the optimal needle insertion site over the lateral pterygoid muscle was determined using the NobelClinician software. A total of 13 patients were injected both with and without the guide, and 4 patients underwent guided injection alone. The therapeutic effects of botulinum toxin injection and its associated complications were statistically compared between the guided and unguided procedures using paired t test. Botulinum toxin therapy was performed 42 and 32 times with and without the guides, respectively. The needle was easily inserted without any complications in all procedures. There was a significant difference (P < .001) between the mean comprehensive improvements observed with (66.3%) and without (54.4%) the guides. The findings suggest that the use of needle guides during the injection of botulinum toxin into the inferior head of the lateral pterygoid muscle is very useful for aiding the accurate and safe administration of botulinum toxin therapy for jaw opening dystonia.

  17. [Discussion on needling sensation, arrival of qi and needling response (Deqi)].

    Science.gov (United States)

    Zhang, Fang; Wang, Hong-Du

    2012-12-01

    The current appointed teaching material of Science of Acupuncture and Moxibustion holds that there is no difference among the needling sensation, arrival of qi and needling response. However, the author has a different understanding. Therefore, Neijing (Internal Classic), its annotation, exposition and understandings of ancient and modern famous experts are cited to analyze their meanings. And the result indicates that the needling sensation is subjective feelings and perceived responses of doctors and patients. Arrival of qi is the healing process of the organ through activating the anti-pathogenic qi to expel the pathogens. The needling response is the final aim of acupuncture therapy. Thus, the meaning of needling sensation, arrival of qi, and needling response are different. And an accurate understanding can better guide acupuncture treatment.

  18. About the diagnostic accuracy rate of fluoroscopy-guided fine needle puncture

    International Nuclear Information System (INIS)

    Wernecke, K.; Teske, H.J.

    1983-01-01

    Percutaneous fine-needle biopsies guided by X-ray were performed in 100 patients utilizing the Nordenstroem canule. All cases have now been clinically controlled for at least 14 and up to 30 months. The follow up allowed further conclusions due to the dignity of histologically negative biopsies. Positive results on malignant lesions were obtained in 74% of cases. Our experience revealed that negative aspiration biopsies should be considered false negative until they could be confirmed by further investigations. (orig.) [de

  19. Predictors of pneumothorax after CT-guided transthoracic needle lung biopsy: the role of quantitative CT.

    Science.gov (United States)

    Chami, H A; Faraj, W; Yehia, Z A; Badour, S A; Sawan, P; Rebeiz, K; Safa, R; Saade, C; Ghandour, B; Shamseddine, A; Mukherji, D; Haydar, A A

    2015-12-01

    To evaluate the association of quantitative computed tomography (CT) measures of emphysema with the occurrence of pneumothorax after CT-guided needle lung biopsy (NLB) accounting for other risk factors. One hundred and sixty-three CT-guided NLBs performed between 2008 and 2013 with available complete chest CT within 30 days were reviewed for the occurrence of post-procedure pneumothorax. Percent emphysema was determined quantitatively as the percentage of lung voxels below -950 HU on chest CT images using automated software. Multivariable regression was used to assess the association of percent emphysema volume with the occurrence of post-procedure pneumothorax. The association of percent emphysema volume with the pneumothorax size and need for chest tube placement after NLB was also explored. Percent emphysema was significantly associated with the incidence of post-NLB pneumothorax (OR=1.10 95% confidence interval: 1.01-1.15; p=0.03) adjusting for lower-lobe lesion location, needle path length, lesion size, number of passes, and pleural needle trajectory angle. Percent emphysema was not associated with the size of the pneumothorax, nor the need for chest tube placement after NLB. Percent emphysema determined quantitatively from chest CT is a significant predictor of post-NLB pneumothorax. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  20. [Non-palpable breast cancer malignant on needle core biopsy and no malignancy in surgical excision: how to manage?].

    Science.gov (United States)

    Cheurfa, N; Giard, S

    2015-01-01

    Despite the standard management of non-palpable breast cancer (needle core biopsy diagnostic, accurate preoperative localization), there are differences in some cases between the malignant histo-pathological finding in diagnostic biopsy results and negative histo-pathological finding after surgical excision. The aim of this study is to evaluate this incidence and classifying them under three category: failure of surgical excision after preoperative identification; removal of the tumor was already completed by percutaneous biopsy; percutaneous biopsy true false positive. We conducted a study based on prospective database, all patients included in this study had partial mastectomy for ductal carcinoma in-situ or invasive cancer which was diagnosed by needle core biopsy and normal/benign after surgery. Regarding the partial mastectomy, 1863 was performed in the last three years in our center. Thirty-seven patients (2%) correspond our study criteria. After discussion of cases in our multidisciplinary reunion, 6 patients (16%) were considered as failure of surgical excision, 26 patients (70%) as true removal of the whole lesion in the core, and 5 patients (13%) as true false-positive cores. This is the first study witch investigate all factors that influence the results of negative final histo-pathological finding of surgical excision of the tumor after malignant diagnostic needle core biopsy. This rare situation need a multidisciplinary meeting to analyse all the steps of management and to determine causes of those false results and try to find adequate management to solve this problem. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  1. Is stereotactic large-core needle biopsy beneficial prior to surgical treatment in BI-RADS 5 lesions?

    NARCIS (Netherlands)

    Hoorntje, LE; Peeters, PHM; Mali, WPTM; Rinkes, IHMB

    Introduction. Due to screening mammography, more nonpalpable mammographic lesions warrant histological evaluation. Stereotactic large-core needle biopsy (SLCNB) has been shown to be as effective in diagnosing these lesions as diagnostic surgical excision, and has become the preferred diagnostic

  2. Computed tomography-guided needle aspiration and biopsy of pulmonary lesions - A single-center experience in 1000 patients

    Energy Technology Data Exchange (ETDEWEB)

    Poulou, Loukia S.; Tsagouli, Paraskevi; Thanos, Loukas [Dept. of Medical Imaging and Interventional Radiology, General Hospital of Chest Diseases ' Sotiria' , Athens (Greece)], e-mail: ploukia@hotmail.com; Ziakas, Panayiotis D. [Program of Outcomes Research, Div. of Infectious Diseases, Warren Alpert Medical School, Brown Univ., RI, and Div. of Infectious Diseases, Rhode Island Hospital, Rhode Island (United States); Politi, Dimitra [Dept. of Cythopathology, General Hospital of Chest Diseases ' Sotiria' Athens (Greece); Trigidou, Rodoula [Dept. of Pathology, General Hospital of Chest Diseases ' Sotiria' Athens (Greece)

    2013-07-15

    Background: Computed tomography (CT)-guided fine needle aspiration (FNA) and biopsies are well-established, minimally invasive diagnostic tools for pulmonary lesions. Purpose: To analyze retrospectively the results of 1000 consecutive lung CT-guided FNA and/or core needle biopsies (CNB), the main outcome measures being diagnostic yield, and complication rates. Material and Methods: Patients considered eligible were those referred to our department for lung lesions. The choice of FNA, CNB, or both was based upon the radiologist's judgment. Diagnostic yield was defined as the probability of having a definite result by cytology/histology. Results: The study included 733 male patients and 267 female patients, with a mean (SD) age of 66.4 (11.4) years. The mean (SD) lesion size was 3.7 (2.4) cm in maximal diameter. Six hundred and forty-one (64%) patients underwent an FNA procedure, 245 (25%) a CNB, and 114 (11%) had been subjected to both. The diagnostic yield was 960/994 (96.6%); this decreased significantly with the use of CNB only (odds ratio [OR] 0.32; 95% CI 0.12 - 0.88; P = 0.03), while it increased with lesion size (OR 1.35; 95% CI 1.03 - 1.79; P = 0.03 per cm increase). In 506 patients (52.7%), a malignant process was diagnosed by cytopathology/histology. The complication rate reached 97/1000 (9.7%); complications included: hemorrhage, 62 (6.2%); pneumothorax, 28 (2.8%); hemorrhage and pneumothorax, 5 (0.5%); and hemoptysis, 2 (0.2%). It was not significantly affected by the type of procedure or localization of the lesion. The overall risk for complications was three times higher for lesions <4 cm (OR 3.26; 95% CI 1.96 - 5.42; P < 0.001). Conclusion: CT-guided lung biopsy has a high diagnostic yield using FNA, CNB, or both. The CNB procedure alone will not suffice. Complication rates were acceptable and correlated inversely with lesion size, not localization or type of procedure.

  3. Fatal paradoxical pulmonary air embolism complicating percutaneous computed tomography-guided needle biopsy of the lung

    International Nuclear Information System (INIS)

    Chakravarti, Rajesh; Singh, Virendra; Isaac, Rethish; John, Joseph

    2004-01-01

    A 63-year-old man with left upper zone haziness on chest X-ray and an infiltrative lesion with a pleural mass in the left upper lobe on CT scan was scheduled for CT-guided percutaneous trans-thoracic needle biopsy. During the procedure, the patient had massive haemoptysis and cardiorespiratory arrest and could not be revived. Post-mortem CT showed air in the right atrium, right ventricle, pulmonary artery and also in the left atrium and aorta. A discussion on paradoxical air embolism following percutaneous trans-thoracic needle biopsy is presented Copyright (2004) Blackwell Publishing Asia Pty Ltd

  4. Diagnosis of mediastinal neoplasms using mediastinoscopy and CT-guided needle biopsy supported by gene analysis

    International Nuclear Information System (INIS)

    Chiba, Wataru; Sawai, Satoru; Ishida, Hisao; Hanawa, Takeshi; Matsubara, Yoshito; Ikeda, Sadao; Kinoshita, Moritoshi; Ikei, Nobuhiro.

    1993-01-01

    Of 140 cases of mediastinal neoplasms in our hospital, histological diagnosis was confirmed in 129 cases. We examined the methods of preoperative biopsy with those 129 cases. Biopsy had been performed in 25 cases. Mediastinoscopy was performed in seven cases, needle biopsy in eight cases, lymph node biopsy in eight cases, esophageal biopsy using a gastrofiberscope in one case, transbronchial biopsy using a bronchoscope in one case. The true positive rates of those methods were 100% for both mediastinoscopy and lymph node biopsy, and 75% for needle biopsy. Preoperative misdiagnosis occurred in two cases of needle biopsy. The postoperative histological diagnosis was malignant lymphoma in both cases. We performed gene analysis of the immunoglobulin heavy chain gene, light chain κ and λ genes, and the T-cell receptor β gene by use of biopsied specimens, and we found rearrangement bands of these genes in the cases of malignant lymphoma. Therefore, we summarize that gene analysis is a reliable method if malignant lymphoma is suspected. If a needle biopsy is performed under CT guidance, the needle is sure to puncture the tumor. We concluded, therefore, that if a tumor is located in the anterior mediastinum, CT-guided needle biopsy should be performed first of all. Mediastinoscopy is a useful method if the tumor is located in the mid-mediastinum. (author)

  5. Needle autopsy to establish the cause of death in HIV-infected hospitalized adults in Uganda: a comparison to complete autopsy.

    Science.gov (United States)

    Cox, Janneke A; Lukande, Robert L; Kalungi, Sam; Van Marck, Eric; Van de Vijver, Koen; Kambugu, Andrew; Nelson, Ann M; Manabe, Yukari C; Colebunders, Robert

    2014-10-01

    Minimal invasive but accurate methods to establish the cause of death in HIV-infected patients are needed. We studied the agreement in cause of death between blind and ultrasound-guided needle autopsy and complete autopsy in HIV-infected patients in Uganda. We subsequently performed a blind and ultrasound-guided needle autopsy followed by a complete autopsy in HIV-infected adults who died during hospitalization. Two teams of pathologists reviewed the tissue from either the needle autopsies or the complete autopsy and formulated the major diagnoses, that is, diseases directly contributing to death. The primary outcome was concordance in major diagnosis between needle and complete autopsies. We performed 96 blind needle and complete autopsies and 95 ultrasound-guided needle autopsies. Concordance in major diagnosis between blind needle and complete autopsy was 50%. For the main major diagnosis, tuberculosis (TB) concordance was higher (71%; P autopsy identified at least 1 major diagnosis in 60% of patients; and in 46%, there was complete concordance for all major diagnoses. The main reason for discordance was sampling error of the lesion. Concordance with the addition of ultrasound guidance was 52% for all major diagnoses and 79% for TB. Major diagnoses were mainly identified in tissue cores from the liver (76%) and the spleen (82%). Blind needle autopsy identified half of the major diagnosis. The addition of ultrasound guidance did not significantly improve the performance of needle autopsy. Needle autopsy is a valuable method to confirm causes of death in HIV-infected patients, especially for highly prevalent diseases like TB.

  6. Comparing Effective Doses During Image-Guided Core Needle Biopsies with Computed Tomography Versus C-Arm Cone Beam CT Using Adult and Pediatric Phantoms

    International Nuclear Information System (INIS)

    Ben-Shlomo, A.; Cohen, D.; Bruckheimer, E.; Bachar, G. N.; Konstantinovsky, R.; Birk, E.; Atar, E.

    2016-01-01

    PurposeTo compare the effective doses of needle biopsies based on dose measurements and simulations using adult and pediatric phantoms, between cone beam c-arm CT (CBCT) and CT.MethodEffective doses were calculated and compared based on measurements and Monte Carlo simulations of CT- and CBCT-guided biopsy procedures of the lungs, liver, and kidney using pediatric and adult phantoms.ResultsThe effective doses for pediatric and adult phantoms, using our standard protocols for upper, middle and lower lungs, liver, and kidney biopsies, were significantly lower under CBCT guidance than CT. The average effective dose for a 5-year old for these five biopsies was 0.36 ± 0.05 mSv with the standard CBCT exposure protocols and 2.13 ± 0.26 mSv with CT. The adult average effective dose for the five biopsies was 1.63 ± 0.22 mSv with the standard CBCT protocols and 8.22 ± 1.02 mSv using CT. The CT effective dose was higher than CBCT protocols for child and adult phantoms by 803 and 590 % for upper lung, 639 and 525 % for mid-lung, and 461 and 251 % for lower lung, respectively. Similarly, the effective dose was higher by 691 and 762 % for liver and 513 and 608 % for kidney biopsies.ConclusionsBased on measurements and simulations with pediatric and adult phantoms, radiation effective doses during image-guided needle biopsies of the lung, liver, and kidney are significantly lower with CBCT than with CT.

  7. Comparing Effective Doses During Image-Guided Core Needle Biopsies with Computed Tomography Versus C-Arm Cone Beam CT Using Adult and Pediatric Phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Ben-Shlomo, A. [Soreq NRC, Radiation Protection Domain (Israel); Cohen, D.; Bruckheimer, E. [Schneider Children’s Medical Center, Section of Pediatric Cardiology (Israel); Bachar, G. N.; Konstantinovsky, R. [Rabin Medical Center, Department of Diagnostic Radiology (Israel); Birk, E. [Schneider Children’s Medical Center, Section of Pediatric Cardiology (Israel); Atar, E., E-mail: elia@clalit.org.il [Rabin Medical Center, Department of Diagnostic Radiology (Israel)

    2016-05-15

    PurposeTo compare the effective doses of needle biopsies based on dose measurements and simulations using adult and pediatric phantoms, between cone beam c-arm CT (CBCT) and CT.MethodEffective doses were calculated and compared based on measurements and Monte Carlo simulations of CT- and CBCT-guided biopsy procedures of the lungs, liver, and kidney using pediatric and adult phantoms.ResultsThe effective doses for pediatric and adult phantoms, using our standard protocols for upper, middle and lower lungs, liver, and kidney biopsies, were significantly lower under CBCT guidance than CT. The average effective dose for a 5-year old for these five biopsies was 0.36 ± 0.05 mSv with the standard CBCT exposure protocols and 2.13 ± 0.26 mSv with CT. The adult average effective dose for the five biopsies was 1.63 ± 0.22 mSv with the standard CBCT protocols and 8.22 ± 1.02 mSv using CT. The CT effective dose was higher than CBCT protocols for child and adult phantoms by 803 and 590 % for upper lung, 639 and 525 % for mid-lung, and 461 and 251 % for lower lung, respectively. Similarly, the effective dose was higher by 691 and 762 % for liver and 513 and 608 % for kidney biopsies.ConclusionsBased on measurements and simulations with pediatric and adult phantoms, radiation effective doses during image-guided needle biopsies of the lung, liver, and kidney are significantly lower with CBCT than with CT.

  8. Helical-Tip Needle for Transthoracic Percutaneous Image-Guided Biopsy of Lung Tumors: Results of a Pilot Prospective Comparative Study with a Standard Tru-Cut Needle

    Energy Technology Data Exchange (ETDEWEB)

    Veltri, Andrea, E-mail: andrea.veltri@unito.it; Busso, Marco; Sardo, Diego; Angelino, Valeria; Priola, Adriano M. [University of Torino, Department of Radiology, San Luigi Gonzaga Hospital (Italy); Novello, Silvia [University of Torino, Department of Oncology, San Luigi Gonzaga Hospital (Italy); Barba, Matteo [University of Torino, Department of Radiology, San Luigi Gonzaga Hospital (Italy); Gatti, Gaia; Righi, Luisella [University of Torino, Department of Pathology, San Luigi Gonzaga Hospital (Italy)

    2017-06-15

    PurposeTo prospectively evaluate feasibility and diagnostic performance of the 14-gauge helical-tip (Spirotome™, Cook{sup ®} Medical, Bloomington, USA) needle in transthoracic needle biopsy (TTNB) of lung lesions, compared to a conventional 18-gauge Tru-Cut needle.Materials and MethodsStudy was institutional review board approved, with informed consent obtained. Data from synchronous Spirotome and Tru-Cut image-guided TTNB of 20 consecutive patients with malignant peripheral lung tumors larger than 3 cm were enrolled for pathologic characterization and mutational analysis. Samples obtained with Spirotome and Tru-Cut needle were compared for fragmentation, length, weight, morphologic and immunohistochemistry typifying, tumor cellularity (TC) and DNA concentration.ResultsThe technical success rate for TTNB with Spirotome was 100%, and no major complications occurred. Less fragmentation (mean 2 vs. 3 fragments, P = .418), greater weight (mean 13 vs. 8.5 mg, P = .027) and lower length (mean 10.2 vs. 12.6 mm, P = .174) were observed with Spirotome compared to Tru-Cut needle. Accuracy of Spirotome and Tru-Cut needle in defining cancer histotype was similar (90%). Absolute and relative TC (mean 42 vs. 38, 124 vs. 108/10HPF), and DNA concentration (mean 49.6 vs. 39.0 ng/μl) were higher with Spirotome compared to Tru-Cut needle, with no statistical significance (P = .787 and P = .140, respectively).Conclusions Percutaneous 14-gauge Spirotome TTNB of selected lesions is feasible and accurate. It provides adequate samples for diagnosis, comparable to 18-gauge Tru-Cut needle, with a higher amount of tumor tissue (weight, TC, DNA concentration) even in shorter samples.

  9. US-guided percutaneous biopsies with a biopsy gun

    International Nuclear Information System (INIS)

    Ahn, In Oak; Kim, Hyung Jin; Kim, Jae Hyung; Lee, Goo; Jung, Sung Hoon

    1993-01-01

    Core tissue for histologic study is believed by many pathologist to be more diagnostic than material from needle aspiration. Recently introduced automatched biopsy gun simplifies core biopsies with increased quantity and quality of samples. Authors performed 38 percutaneous biopsies from 38 patients with 18G automated biopsy guns under US guide. Diagnostic target tissues were obtained in 33 biopsies(87%), inadequate tissues in 4(11%), and adequate but not of target tissue in 1(3%). There was no major complication requiring treatment, but pain needing analgesics and pain with nausea/vomiting were experienced in 2 and 1 biopsies respectively. Average number of needle passes was 1.5. We concluded that US guided gun biopsy was a easy and safe way to obtain tissue samples of good quantity and quality, especially useful in hospitals without constant availability of specialist in cytopathology

  10. Core needle biopsy of the thyroid: 2016 consensus statement and recommendations from Korea society of thyroid radiology

    Energy Technology Data Exchange (ETDEWEB)

    Na, Dong Gyu [Dept. of Radiology, Human Medical Imaging and Intervention Center, Seoul (Korea, Republic of); Baek, Jung Hwan; Lee, Jeong Hyun [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of); and others

    2017-01-15

    Core needle biopsy (CNB) has been suggested as a complementary diagnostic method to fine-needle aspiration in patients with thyroid nodules. Many recent CNB studies have suggested a more advanced role for CNB, but there are still no guidelines on its use. Therefore, the Task Force Committee of the Korean Society of Thyroid Radiology has developed the present consensus statement and recommendations for the role of CNB in the diagnosis of thyroid nodules. These recommendations are based on evidence from the current literature and expert consensus.

  11. EEA core set of indicators. Guide

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-01

    This guide provides information on the quality of the 37 indicators in the EEA core set. Its primary role is to support improved implementation of the core set in the EEA, European topic centres and the European environment information and observation network (Eionet). In parallel, it is aimed at helping users outside the EEA/Eionet system make best use of the indicators in their own work. It is hoped that the guide will promote cooperation on improving indicator methodologies and data quality as part of the wider process to streamline and improve environmental reporting in the European Union and beyond. (au)

  12. Needle-tissue interactive mechanism and steering control in image-guided robot-assisted minimally invasive surgery: a review.

    Science.gov (United States)

    Li, Pan; Yang, Zhiyong; Jiang, Shan

    2018-06-01

    Image-guided robot-assisted minimally invasive surgery is an important medicine procedure used for biopsy or local target therapy. In order to reach the target region not accessible using traditional techniques, long and thin flexible needles are inserted into the soft tissue which has large deformation and nonlinear characteristics. However, the detection results and therapeutic effect are directly influenced by the targeting accuracy of needle steering. For this reason, the needle-tissue interactive mechanism, path planning, and steering control are investigated in this review by searching literatures in the last 10 years, which results in a comprehensive overview of the existing techniques with the main accomplishments, limitations, and recommendations. Through comprehensive analyses, surgical simulation for insertion into multi-layer inhomogeneous tissue is verified as a primary and propositional aspect to be explored, which accurately predicts the nonlinear needle deflection and tissue deformation. Investigation of the path planning of flexible needles is recommended to an anatomical or a deformable environment which has characteristics of the tissue deformation. Nonholonomic modeling combined with duty-cycled spinning for needle steering, which tracks the tip position in real time and compensates for the deviation error, is recommended as a future research focus in the steering control in anatomical and deformable environments. Graphical abstract a Insertion force when the needle is inserted into soft tissue. b Needle deflection model when the needle is inserted into soft tissue [68]. c Path planning in anatomical environments [92]. d Duty-cycled spinning incorporated in nonholonomic needle steering [64].

  13. Enabling image fusion for a CT guided needle placement robot

    Science.gov (United States)

    Seifabadi, Reza; Xu, Sheng; Aalamifar, Fereshteh; Velusamy, Gnanasekar; Puhazhendi, Kaliyappan; Wood, Bradford J.

    2017-03-01

    Purpose: This study presents development and integration of hardware and software that enables ultrasound (US) and computer tomography (CT) fusion for a FDA-approved CT-guided needle placement robot. Having real-time US image registered to a priori-taken intraoperative CT image provides more anatomic information during needle insertion, in order to target hard-to-see lesions or avoid critical structures invisible to CT, track target motion, and to better monitor ablation treatment zone in relation to the tumor location. Method: A passive encoded mechanical arm is developed for the robot in order to hold and track an abdominal US transducer. This 4 degrees of freedom (DOF) arm is designed to attach to the robot end-effector. The arm is locked by default and is released by a press of button. The arm is designed such that the needle is always in plane with US image. The articulated arm is calibrated to improve its accuracy. Custom designed software (OncoNav, NIH) was developed to fuse real-time US image to a priori-taken CT. Results: The accuracy of the end effector before and after passive arm calibration was 7.07mm +/- 4.14mm and 1.74mm +/-1.60mm, respectively. The accuracy of the US image to the arm calibration was 5mm. The feasibility of US-CT fusion using the proposed hardware and software was demonstrated in an abdominal commercial phantom. Conclusions: Calibration significantly improved the accuracy of the arm in US image tracking. Fusion of US to CT using the proposed hardware and software was feasible.

  14. Laparoscopic and Percutaneous Core Needle Biopsy Plays a Central Role for the Diagnosis of Autoimmune Pancreatitis in a Single-Center Study from Denmark

    DEFF Research Database (Denmark)

    Detlefsen, Sönke; Mortensen, Michael Bau; Kjærulf Pless, Torsten

    2015-01-01

    organ involvement was observed in 40% of type 1 and 13% of type 2, but inflammatory bowel disease only in type 2 (P = 0.001). One patient had IgG4-related chronic perisplenitis as a hitherto undescribed manifestation of IgG4-related disease. Nineteen (91%) of 21 biopsied patients had diagnostic CNB...... Hospital from 2007 to 2013 were included (n = 30; mean follow-up, 26.2 months). Data from laparoscopic or percutaneous ultrasound-guided core needle biopsy (CNB), resection specimens, endoscopic ultrasound (EUS), EUS-guided CNB, computed tomography, serum immunoglobulin G4 (IgG4), and pancreatography were...... retrospectively analyzed according to ICDC. RESULTS: Twenty patients were diagnosed with type 1, 8 with type 2, and 2 with not otherwise specified AIP. Twenty-eight patients (93%) could correctly be classified when ICDC were retrospectively applied. Serum IgG4 was elevated in 44% of type 1 and 0% of type 2. Other...

  15. Bone marrow solid core biopsy needle: a critical assessment of the utility, benefits and limitations of the instruments employed in current day haematology and oncology.

    Science.gov (United States)

    Islam, Anwarul

    2018-06-01

    The optimal clinical evaluation of the bone marrow requires an examination of air-dried and well-stained films of the aspirated tissue along with a histopathological evaluation of adequately processed and properly stained core biopsy specimens. A bone marrow evaluation can be essential in establishing a diagnosis, determining the efficacy of treatment in haematological disorders and to monitor haematological status of patients following bone marrow/stem cell transplantation. It is also an essential component of the staging process for newly diagnosed malignancies. Currently available bone marrow aspiration needles are quite satisfactory and if properly used provide good-quality specimens for morphological evaluation. However, if a bone marrow core biopsy is concerned, several needles are currently in use but not all of them provide good-quality biopsy specimens for histological evaluation or are user friendly. We have compared the recently introduced Moeller Medical single use bone marrow core biopsy needle with the Jamshidi needle with marrow acquisition cradle (CareFusion), J-needle (Cardinal Health) and OnControl device (Vidacare). It is concluded that the Moeller Medical needle system has definite advantages over others and is recommended for routine use. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  16. Distinguishing papillary endothelial hyperplasia and angiosarcoma on core needle biopsy of the breast: The importance of clinical and radiologic correlation.

    Science.gov (United States)

    Guilbert, Marie-Christine; Frost, Elisabeth P; Brock, Jane E; Lester, Susan C

    2018-02-24

    Papillary endothelial hyperplasia (PEH) is a rare non-neoplastic exuberant organizing hematoma that can closely mimic angiosarcoma due to a resemblance to malignant anastomosing blood vessels. It could be particularly difficult to distinguish PEH from angiosarcoma in breast core needle biopsies. We identified all cases of these lesions diagnosed on core needle biopsy in order to identify clinical, radiologic, and pathologic features that could prove helpful to arrive at the correct diagnosis. Four cases of PEH and 4 cases of angiosarcoma were identified. The mean age at diagnosis was 62 for PEH and 33 for primary angiosarcoma. All cases of PEH formed small masses with circumscribed or lobulated margins by imaging (mean size 0.9 cm). In 3 cases, the masses were difficult or impossible to identify after the biopsy. Angiosarcomas presented as larger masses with ill-defined margins (mean size 2.8 cm) that were unchanged in size after biopsy. PEH was surrounded by adipose tissue, whereas angiosarcoma invaded into fibrous stroma and involved lobules. The pseudopapillary structures of PEH were composed mainly of collagen, and thus, additional histologic stains for fibrin were not helpful for diagnosis. The 4 patients with PEH received no further treatment and are alive and disease-free at 2-11 years of follow-up. In contrast, the patients with angiosarcoma underwent mastectomy and chemotherapy or radiation therapy. Two of the patients with angiosarcoma died 3 years after diagnosis and the other 2 patients are alive without disease at 5 and 6 years. Therefore, distinguishing PEH and angiosarcoma is essential for appropriate management. This is the first series to compare these lesions on core needle biopsy and the first to note important clinical, imaging, and histologic differences that aid in making a diagnosis of PEH with confidence on breast core needle biopsy. © 2018 Wiley Periodicals, Inc.

  17. Rapid needle-out patient-rollover approach after cone beam CT-guided lung biopsy: effect on pneumothorax rate in 1,191 consecutive patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Im [Seoul National University College of Medicine, Department of Radiology, Jongno-gu, Seoul (Korea, Republic of); Seoul National University Medical Research Center, Institute of Radiation Medicine, Seoul (Korea, Republic of); Kyung Hee University Hospital at Gangdong, Kyung Hee University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Park, Chang Min; Goo, Jin Mo [Seoul National University College of Medicine, Department of Radiology, Jongno-gu, Seoul (Korea, Republic of); Seoul National University, Cancer Research Institute, Seoul (Korea, Republic of); Lee, Sang Min [Seoul National University College of Medicine, Department of Radiology, Jongno-gu, Seoul (Korea, Republic of)

    2015-07-15

    To investigate the effect of rapid needle-out patient-rollover approach on the incidence of pneumothorax and drainage catheter placement due to pneumothorax in C-arm Cone-beam CT (CBCT)-guided percutaneous transthoracic needle biopsy (PTNB) of lung lesions. From May 2011 to December 2012, 1227 PTNBs were performed in 1191 patients with a 17-gauge coaxial needle. 617 biopsies were performed without (conventional-group) and 610 with rapid-rollover approach (rapid-rollover-group). Overall pneumothorax rates and incidences of pneumothorax requiring drainage catheter placement were compared between two groups. There were no significant differences in overall pneumothorax rates between conventional and rapid-rollover groups (19.8 % vs. 23.1 %, p = 0.164). However, pneumothorax rate requiring drainage catheter placement was significantly lower in rapid-rollover-group (1.6 %) than conventional-group (4.2 %) (p = 0.010). Multivariate analysis revealed male, age > 60, bulla crossed, fissure crossed, pleura to target distance > 1.3 cm, emphysema along needle tract, and pleural punctures ≥ 2 were significant risk factors of pneumothorax (p < 0.05). Regarding pneumothorax requiring drainage catheter placement, fissure crossed, bulla crossed, and emphysema along needle tract were significant risk factors (p < 0.05), whereas rapid-rollover approach was an independent protective factor (p = 0.002). The rapid needle-out patient-rollover approach significantly reduced the rate of pneumothorax requiring drainage catheter placement after CBCT-guided PTNB. (orig.)

  18. WE-AB-BRA-10: Assessment of Fiber Bragg Grating (FBG)-Based Sensing for Real-Time Needle Tracking During MR-Guided Brachytherapy

    International Nuclear Information System (INIS)

    Borot de Battisti, M; Maenhout, M; Lagendijk, J J W; Van Vulpen, M; Moerland, M A; Denis de Senneville, B; Hautvast, G; Binnekamp, D

    2016-01-01

    Purpose: This study assesses the potential of Fiber Bragg Grating (FBG)-based sensing for real-time needle (including catheter or tube) tracking during MR-guided HDR brachytherapy. Methods: The proposed FBG-based sensing tracking approach involves a MR-compatible stylet composed of three optic fibers with nine sets of embedded FBG sensors each. When the stylet is inserted inside the lumen of the needle, the FBG sensing system can measure the needle’s deflection. For localization of the needle in physical space, the position and orientation of the stylet base are mandatory. For this purpose, we propose to fix the stylet base and determine its position and orientation using a MR-based calibration as follows. First, the deflection of a needle inserted in a phantom in two different configurations is measured during simultaneous MR-imaging. Then, after segmentation of the needle shapes on the MR-images, the position and orientation of the stylet base is determined using a rigid registration of the needle shapes on both MR and FBG-based measurements. The calibration method was assessed by measuring the deflection of a needle in a prostate phantom in five different configurations using FBG-based sensing during simultaneous MR-imaging. Any two needle shapes were employed for the calibration step and the proposed FGB-tracking approach was subsequently evaluated on the other three needles configurations. The tracking accuracy was evaluated by computing the Euclidian distance between the 3D FBG vs. MR-based measurements. Results: Over all needle shapes tested, the average(standard deviation) Euclidian distance between the FBG and MR-based measurements was 0.79mm(0.37mm). The update rate and latency of the FBG-based measurements were 100ms and 300ms respectively. Conclusion: The proposed FBG-based protocol can measure the needle position with an accuracy, precision, update rate and latency eligible for accurate needle steering during MR-guided HDR brachytherapy. M. Borot de

  19. Comparison between fine needle aspiration cytology (FNAC) and core needle biopsy (CNB) in the diagnosis of breast lesions.

    Science.gov (United States)

    Moschetta, M; Telegrafo, M; Carluccio, D A; Jablonska, J P; Rella, L; Serio, Gabriella; Carrozzo, M; Stabile Ianora, A A; Angelelli, G

    2014-01-01

    To compare the diagnostic accuracy of fine-needle aspiration cytology (FNAC) and core needle biopsy (CNB) in patients with USdetected breast lesions. Between September 2011 and May 2013, 3469 consecutive breast US examinations were performed. 400 breast nodules were detected in 398 patients. 210 FNACs and 190 CNBs were performed. 183 out of 400 (46%) lesions were surgically removed within 30 days form diagnosis; in the remaining cases, a six month follow up US examination was performed. Sensitivity, specificity, diagnostic accuracy, positive predictive (PPV) and negative predictive (NPV) values were calculated for FNAC and CNB. 174 out of 400 (43%) malignant lesions were found while the remaining 226 resulted to be benign lesions. 166 out of 210 (79%) FNACs and 154 out of 190 (81%) CNBs provided diagnostic specimens. Sensitivity, specificity, diagnostic accuracy, PPV and NPV of 97%, 94%, 95%, 91% and 98% were found for FNAC, and values of 92%, 82%, 89%, 92% and 82% were obtained for CNB. Sensitivity, specificity, diagnostic accuracy, PPV and NPV of 97%, 96%, 96%, 97% and 96% were found for FNAC, and values of 97%, 96%, 96%, 97% and 96% were obtained for CNB. FNAC and CNB provide similar values of diagnostic accuracy.

  20. 78 FR 66932 - Scientific Information Request on Core Needle and Open Surgical Biopsy for Diagnosis of Breast...

    Science.gov (United States)

    2013-11-07

    ... is women who have been referred for biopsy for the diagnosis of primary breast cancer (including... diagnosis of breast cancer) are excluded. Comparators (Reference Standard and Comparator Index Tests) For... Information Request on Core Needle and Open Surgical Biopsy for Diagnosis of Breast Lesions AGENCY: Agency for...

  1. Computed tomographic fluoroscopy-guided transthoracic needle biopsy for diagnosis of pulmonary nodules

    International Nuclear Information System (INIS)

    Hirose, Takashi; Mori, Kiyoshi; Machida, Suguru; Tominaga, Keigo; Yokoi, Kohei; Adachi, Mitsuru

    2000-01-01

    The purpose of this study was to evaluate the usefulness of computed tomographic (CT) fluoroscopy-guided transthoracic needle biopsy (TTNB) with an 18-gauge automatic biopsy gun for the diagnosis of pulmonary nodules. Between March 1996 and January 1998, 50 patients in whom pulmonary lesions could not be diagnosed cytopathologically with fiberoptic bronchoscopy or were not clearly visualized with fluoroscopy underwent CT fluoroscopy-guided TTNB. Final pathological diagnoses were 23 lung carcinomas, five pulmonary metastases and 22 benign lesions. Sufficient tissue for analysis was obtained from 48 of the 50 lesions (96%). The overall diagnostic yield of CT fluoroscopy-guided TTNB was 90%. The sensitivity, specificity and accuracy for malignancy were 89%, 100% and 94%, respectively. In 20 of the 22 cases (91%) of benign lesions, histological analysis yielded correct and specific diagnoses. Complications occurred in 22 of the 50 cases (44%). The most common complication was pneumothorax, which occurred in 21 of the 50 cases (42%). Chest tube insertion was required in 6 (12%). Although CT fluoroscopy could not decrease the complication rate, CT fluoroscopy-guided TTNB with an automatic biopsy gun appears to be a promising technique for diagnosing pulmonary lesions, particularly benign lesions. (author)

  2. Laser Generated Leaky Acoustic Waves for Needle Visualization.

    Science.gov (United States)

    Wu, Kai-Wen; Wang, Yi-An; Li, Pai-Chi

    2018-04-01

    Ultrasound (US)-guided needle operation is usually used to visualize both tissue and needle position such as tissue biopsy and localized drug delivery. However, the transducer-needle orientation is limited due to reflection of the acoustic waves. We proposed a leaky acoustic wave method to visualize the needle position and orientation. Laser pulses are emitted on top of the needle to generate acoustic waves; then, these acoustic waves propagate along the needle surface. Leaky wave signals are detected by the US array transducer. The needle position can be calculated by phase velocities of two different wave modes and their corresponding emission angles. In our experiments, a series of needles was inserted into a tissue mimicking phantom and porcine tissue to evaluate the accuracy of the proposed method. The results show that the detection depth is up to 51 mm and the insertion angle is up to 40° with needles of different diameters. It is demonstrated that the proposed approach outperforms the conventional B-mode US-guided needle operation in terms of the detection range while achieving similar accuracy. The proposed method reveals the potentials for further clinical applications.

  3. Comparison of a GPS needle-tracking system, multiplanar imaging and 2D imaging for real-time ultrasound-guided epidural anaesthesia: A randomized, comparative, observer-blinded study on phantoms.

    Science.gov (United States)

    Menacé, Cécilia; Choquet, Olivier; Abbal, Bertrand; Bringuier, Sophie; Capdevila, Xavier

    2017-04-01

    The real-time ultrasound-guided paramedian sagittal oblique approach for neuraxial blockade is technically demanding. Innovative technologies have been developed to improve nerve identification and the accuracy of needle placement. The aim of this study was to evaluate three types of ultrasound scans during ultrasound-guided epidural lumbar punctures in a spine phantom. Eleven sets of 20 ultrasound-guided epidural punctures were performed with 2D, GPS, and multiplanar ultrasound machines (660 punctures) on a spine phantom using an in-plane approach. For all punctures, execution time, number of attempts, bone contacts, and needle redirections were noted by an independent physician. Operator comfort and visibility of the needle (tip and shaft) were measured using a numerical scale. The use of GPS significantly decreased the number of punctures, needle repositionings, and bone contacts. Comfort of the physician was also significantly improved with the GPS system compared with the 2D and multiplanar systems. With the multiplanar system, the procedure was not facilitated and execution time was longer compared with 2D imaging after Bonferroni correction but interaction between the type of ultrasound system and mean execution time was not significant in a linear mixed model. There were no significant differences regarding needle tip and shaft visibility between the systems. Multiplanar and GPS needle-tracking systems do not reduce execution time compared with 2D imaging using a real-time ultrasound-guided paramedian sagittal oblique approach in spine phantoms. The GPS needle-tracking system can improve performance in terms of operator comfort, the number of attempts, needle redirections and bone contacts. Copyright © 2016 Société française d'anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.

  4. Predictors of pneumothorax after CT-guided transthoracic needle lung biopsy: the role of quantitative CT

    International Nuclear Information System (INIS)

    Chami, H.A.; Faraj, W.; Yehia, Z.A.; Badour, S.A.; Sawan, P.; Rebeiz, K.; Safa, R.; Saade, C.; Ghandour, B.; Shamseddine, A.; Mukherji, D.; Haydar, A.A.

    2015-01-01

    Aim: To evaluate the association of quantitative computed tomography (CT) measures of emphysema with the occurrence of pneumothorax after CT-guided needle lung biopsy (NLB) accounting for other risk factors. Materials and methods: One hundred and sixty-three CT-guided NLBs performed between 2008 and 2013 with available complete chest CT within 30 days were reviewed for the occurrence of post-procedure pneumothorax. Percent emphysema was determined quantitatively as the percentage of lung voxels below −950 HU on chest CT images using automated software. Multivariable regression was used to assess the association of percent emphysema volume with the occurrence of post-procedure pneumothorax. The association of percent emphysema volume with the pneumothorax size and need for chest tube placement after NLB was also explored. Results: Percent emphysema was significantly associated with the incidence of post-NLB pneumothorax (OR=1.10 95% confidence interval: 1.01–1.15; p=0.03) adjusting for lower-lobe lesion location, needle path length, lesion size, number of passes, and pleural needle trajectory angle. Percent emphysema was not associated with the size of the pneumothorax, nor the need for chest tube placement after NLB. Conclusion: Percent emphysema determined quantitatively from chest CT is a significant predictor of post-NLB pneumothorax. - Highlights: • Examine the association between quantitative emphysema measures & post NLB pneumothorax. • The risk of post-NLB pneumothorax increases with every unit increase in percent emphysema. • Percent emphysema is a significant predictor of pneumothorax post transthoracic NLB. • Quantitative analysis of chest CT offers clinicians' objective measures to assess pneumothorax risk.

  5. Diagnosis of verminous pneumonia via sonography-guided fine-needle pulmonary parenchymal aspiration in a cat

    Directory of Open Access Journals (Sweden)

    Jennifer Gambino

    2016-04-01

    Full Text Available Case summary A 9-year-old, male neutered, indoor–outdoor domestic shorthair cat from the northern Alabama countryside presented for a 3 week history of coughing, lethargy and an episode of self-resolving dyspnea that occurred 1 week prior to presentation. Three-view thoracic radiographs revealed a moderate-to-severe, diffuse, mixed bronchial to structured interstitial (miliary-to-nodular pulmonary pattern in all lung lobes with peribronchial cuffing and multifocal areas of mild patchy alveolar opacity. Ultrasound-guided evaluation and fine-needle aspiration of the caudodorsal lung parenchyma was performed with sedation. Cytology revealed many widely scattered Aelurostrongylus abstrusus larvae and ova. Upon the confirmed diagnosis of A abstrusus verminous pneumonia, treatment with fenbendazole and selamectin resulted in complete resolution of clinical signs within 6 weeks of the initial diagnosis. Relevance and novel information We report herein the first documented case in the Americas of A abstrusus verminous pneumonia diagnosed via cytologic evaluation of an in vivo, percutaneous ultrasound-guided fine-needle aspirate of affected lung. Additionally, to our knowledge, we offer the first account of the sonographic (pulmonary features of the disease.

  6. Effectiveness of combined use of imprint cytological and histological examination in CT-guided tissue-core biopsy

    International Nuclear Information System (INIS)

    Yamagami, Takuji; Yoshimatsu, Rika; Kajiwara, Kenji; Ishikawa, Masaki; Awai, Kazuo; Matsumoto, Tomohiro; Hasebe, Terumitsu; Kakizawa, Hideaki; Toyoda, Naoyuki

    2014-01-01

    This study evaluated the efficacy of the combination of imprint cytology and histology in tissue-core percutaneous biopsy under real-time computed tomography (CT) fluoroscopic guidance. Between October 2009 and June 2013, 156 percutaneous needle biopsies were performed in our institution. Those obtained by tissue-core biopsy underwent both imprint cytological and histological examinations routinely after touch imprint cytology was performed on site to evaluate the samples' sufficiency for cytological and pathological examination. Final diagnosis was confirmed by independent surgical pathology, independent culture results or clinical follow-up. Rates of adequate specimens and precise diagnosis, by combined cytological and histological examination were 100 % (156/156) and 96.2 % (150/156), by cytology 94.4 % (152/156) and 83.3 % (130/156) and by histology 99.3 % (155/156) and 92.3 % (144/156). Precise diagnosis was achieved by combined examinations in 94.7 % (89/94) of thoracic lesions, 97.6 % (40/41) of musculoskeletal lesions, and 100 % (21/21) of abdominal, pelvic and retroperitoneal lesions. In all 104 lesions diagnosed as malignant by CT-guided biopsy and in 30 of 52 diagnosed as benign, specific cell types could be proved by combined examinations. Combined imprint cytology and histology performed after on-site touch imprint cytological evaluation improved the diagnostic ability of CT fluoroscopically guided biopsy. (orig.)

  7. Effectiveness of combined use of imprint cytological and histological examination in CT-guided tissue-core biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Yamagami, Takuji; Yoshimatsu, Rika; Kajiwara, Kenji; Ishikawa, Masaki; Awai, Kazuo [Hiroshima University, Department of Diagnostic Radiology, Institute and Graduate School of Biomedical Sciences, Minami-Ku, Hiroshima (Japan); Matsumoto, Tomohiro; Hasebe, Terumitsu [Tokai University Hachioji Hospital, Tokai University School of Medicine, Department of Radiology, Hachioji, Tokyo (Japan); Kakizawa, Hideaki [Hiroshima University, Department of Diagnostic Radiology, Institute and Graduate School of Biomedical Sciences, Minami-Ku, Hiroshima (Japan); Hiroshima Red Cross Hospital and Atomic-bomb Survivors Hospital, Department of Diagnostic Radiology, Naka-Ku, Hiroshima (Japan); Toyoda, Naoyuki [Hiroshima University, Department of Diagnostic Radiology, Institute and Graduate School of Biomedical Sciences, Minami-Ku, Hiroshima (Japan); National Hospital Organisation Kure Medical Centre, Department of Diagnostic Radiology, Kure, Hiroshima (Japan)

    2014-05-15

    This study evaluated the efficacy of the combination of imprint cytology and histology in tissue-core percutaneous biopsy under real-time computed tomography (CT) fluoroscopic guidance. Between October 2009 and June 2013, 156 percutaneous needle biopsies were performed in our institution. Those obtained by tissue-core biopsy underwent both imprint cytological and histological examinations routinely after touch imprint cytology was performed on site to evaluate the samples' sufficiency for cytological and pathological examination. Final diagnosis was confirmed by independent surgical pathology, independent culture results or clinical follow-up. Rates of adequate specimens and precise diagnosis, by combined cytological and histological examination were 100 % (156/156) and 96.2 % (150/156), by cytology 94.4 % (152/156) and 83.3 % (130/156) and by histology 99.3 % (155/156) and 92.3 % (144/156). Precise diagnosis was achieved by combined examinations in 94.7 % (89/94) of thoracic lesions, 97.6 % (40/41) of musculoskeletal lesions, and 100 % (21/21) of abdominal, pelvic and retroperitoneal lesions. In all 104 lesions diagnosed as malignant by CT-guided biopsy and in 30 of 52 diagnosed as benign, specific cell types could be proved by combined examinations. Combined imprint cytology and histology performed after on-site touch imprint cytological evaluation improved the diagnostic ability of CT fluoroscopically guided biopsy. (orig.)

  8. An ultrasound-driven needle-insertion robot for percutaneous cholecystostomy

    International Nuclear Information System (INIS)

    Hong, J; Dohi, T; Hashizume, M; Konishi, K; Hata, N

    2004-01-01

    A real-time ultrasound-guided needle-insertion medical robot for percutaneous cholecystostomy has been developed. Image-guided interventions have become widely accepted because they are consistent with minimal invasiveness. However, organ or abnormality displacement due to involuntary patient motion may undesirably affect the intervention. The proposed instrument uses intraoperative images and modifies the needle path in real time by using a novel ultrasonic image segmentation technique. In phantom and volunteer experiments, the needle path updating time was 130 and 301 ms per cycle, respectively. In animal experiments, the needle could be placed accurately in the target

  9. Endobronchial Ultrasound-guided Transbronchial Needle Injection of Liposomal Amphotericin B for the Treatment of Symptomatic Aspergilloma.

    Science.gov (United States)

    Parikh, Mihir S; Seeley, Eric; Nguyen-Tran, Evelyn; Krishna, Ganesh

    2017-10-01

    Surgical treatment with lung resection has traditionally been the treatment of choice for pulmonary cavities containing aspergillomas that cause hemoptysis. Endobronchial ultrasound (EBUS) is a minimally invasive bronchoscopic technique that is commonly used for transbronchial needle aspiration of hilar and mediastinal lymph nodes as well as centrally located parenchymal lesions. Here, we describe a case of a 71-year-old woman who was found to have a cavitary lesion in the lung containing aspergillomas. Under direct ultrasound visualization with EBUS, liposomal amphotericin B was injected into the aspergillomas. These aspergillomas regressed after treatment. To our knowledge, this is the first reported treatment of aspergilloma with EBUS-guided transbronchial needle injection of liposomal amphotericin B.

  10. Guiding Properties of Silica/Air Hollow-Core Bragg Fibers

    DEFF Research Database (Denmark)

    Foroni, Matteo; Passaro, Davide; Poli, Federica

    2008-01-01

    The guiding properties of realistic silica/air hollow-core Bragg fibers have been investigated by calculating the dispersion curves, the confinement loss spectrum and the field distribution of the guided modes through a full-vector modal solver based on the finite element method. In particular, t...... the different possible applications, the feasibility of a DNA bio-sensor based on a hollow-core Bragg fiber has been demonstrated....

  11. Development and evaluation of a prediction model for underestimated invasive breast cancer in women with ductal carcinoma in situ at stereotactic large core needle biopsy.

    Directory of Open Access Journals (Sweden)

    Suzanne C E Diepstraten

    Full Text Available BACKGROUND: We aimed to develop a multivariable model for prediction of underestimated invasiveness in women with ductal carcinoma in situ at stereotactic large core needle biopsy, that can be used to select patients for sentinel node biopsy at primary surgery. METHODS: From the literature, we selected potential preoperative predictors of underestimated invasive breast cancer. Data of patients with nonpalpable breast lesions who were diagnosed with ductal carcinoma in situ at stereotactic large core needle biopsy, drawn from the prospective COBRA (Core Biopsy after RAdiological localization and COBRA2000 cohort studies, were used to fit the multivariable model and assess its overall performance, discrimination, and calibration. RESULTS: 348 women with large core needle biopsy-proven ductal carcinoma in situ were available for analysis. In 100 (28.7% patients invasive carcinoma was found at subsequent surgery. Nine predictors were included in the model. In the multivariable analysis, the predictors with the strongest association were lesion size (OR 1.12 per cm, 95% CI 0.98-1.28, number of cores retrieved at biopsy (OR per core 0.87, 95% CI 0.75-1.01, presence of lobular cancerization (OR 5.29, 95% CI 1.25-26.77, and microinvasion (OR 3.75, 95% CI 1.42-9.87. The overall performance of the multivariable model was poor with an explained variation of 9% (Nagelkerke's R(2, mediocre discrimination with area under the receiver operating characteristic curve of 0.66 (95% confidence interval 0.58-0.73, and fairly good calibration. CONCLUSION: The evaluation of our multivariable prediction model in a large, clinically representative study population proves that routine clinical and pathological variables are not suitable to select patients with large core needle biopsy-proven ductal carcinoma in situ for sentinel node biopsy during primary surgery.

  12. Endoscopic ultrasound-guided fine-needle aspiration cytology in the evaluation of suspected tuberculosis in patients with isolated mediastinal lymphadenopathy

    DEFF Research Database (Denmark)

    Puri, R.; Vilmann, P.; Sud, R.

    2010-01-01

    Patients with suspected tuberculosis without pulmonary lesions and with mediastinal lymphadenopathy often pose a diagnostic challenge. Endoscopic ultrasound (EUS)-guided fine-needle aspiration (FNA) cytology is an established modality to evaluate mediastinal and abdominal lesions. The aim...

  13. Diagnostic accuracy of percutaneous cytodiagnosis of hepatic masses, by ultrasound guided fine needle aspiration cytology

    International Nuclear Information System (INIS)

    Asghar, F.; Riaz, S.

    2010-01-01

    Objective: To evaluate the diagnostic accuracy, usefulness and limitations of ultrasound guided FNAC of hepatic masses. Design: Cross - sectional analytical (comparative study). Place and Duration: Department of histopathology, Sheikh Zayed Hospital, Lahore. Study period 1 year. Material and Methods: A total of 32 patients with solitary or multiple hepatic masses underwent FNAC from March 1999 to March 2000. Adequate aspirates were obtained in all these cases. Smears were stained with May-Grunwald Giemsa, Haematoxylin and Eosin and Papanicolaou stain. Needle biopsies from the same cases were also obtained and processed. These were stained with routine Haematoxylin and Eosin staining. The blood clots obtained during FNAC were fixed in 10% neu-tral buffered formalin. The histopathology of these blood clots was used for cases whose needle core biopsy was not available. The screened FNAC smears were divided into 3 categories i.e., benign (group - I), malignant (group - II), non-neoplastic / inflammatory lesions (including cysts and abscesses) (group - III). Results: Out of 32 cases, 6 were categorized as benign, 18 as malignant, and 8 as non-neoplastic inflammatory lesions. Three false negative diagnoses, including 1 for malignant tumour and 2 for benign tumours was obtained. There was 1 false positive diagnosis for malignancy. FNAC - histological correlation showed a 94.2% sensitivity and 92.3% diagnostic accuracy for malignant tumours, while benign tumours posed maximum diagnostic problems, giving a 66.67% sensitivity and 85.7% diagnostic accuracy. FNAC picked up correctly all the non-neoplastic lesions giving a 100% sensitivity and diagnostic accuracy. Conclusion: Majority of the malignant tumours can be categorized on FNAC, with a high degree of accuracy, while benign tumours should be subjected to biopsy, as there is a relatively greater possibility of false negative diagnosis. (author)

  14. Pancreatic metastases from ocular malignant melanoma: the use of endoscopic ultrasound-guided fine-needle aspiration to establish a definitive cytologic diagnosis: a case report

    Directory of Open Access Journals (Sweden)

    Diogo Turiani Hourneaux De Moura

    2016-12-01

    Full Text Available Abstract Background When encountering solid pancreatic lesions, nonpancreatic primary metastases are rare and differentiating a metastasis from a primary neoplastic lesion is challenging. The clinical presentation and radiologic features can be similar and the possibility of a pancreatic metastasis should be considered when the patient refers to a history of a different primary cancer. Endoscopic ultrasound offers a key anatomical advantage in accessing the pancreas and endoscopic ultrasound-guided fine-needle aspiration has become the gold standard method for diagnosing pancreatic lesions. Case presentation A 58-year-old white Hispanic woman with a history of uveal malignant melanoma, presented with abdominal pain and jaundice. On admission, laboratory tests were performed (her total bilirubin was 6.37 mg/dL with a direct fraction of 5.30 mg/dL. Cross-sectional, abdominal computed tomography with contrast, showed a low-attenuating lesion localized in the pancreatic head (measuring 4 × 3 cm and a thinner section of the distal bile duct suspicious for compression. Our patient was scheduled for an endoscopic ultrasound-guided fine-needle aspiration to establish a diagnosis. Endoscopic ultrasound showed a solid, hypoechoic, well-defined lesion with regular contours (measuring 3.17 × 2.61 cm, localized between the head and neck of the pancreas. Endoscopic ultrasound-guided fine-needle aspiration was performed with a 22G needle and cytology confirmed the diagnosis of metastatic melanoma. Our patient subsequently underwent right orbital exenteration, followed by duodenopancreatectomy without complications. At the moment our patient is receiving adjuvant chemotherapy at an outside oncology clinic. Conclusions To the best of our knowledge, this is a very rare presentation of an ocular malignant melanoma with an isolated pancreatic metastasis causing symptomatic biliary obstruction. Endoscopic ultrasound-guided fine-needle aspiration has

  15. Analysis of a Steerable Needle for Fine Needle Aspiration and Biopsy: Efficiency and Radiation Dose Compared With a Conventional Straight Needle.

    Science.gov (United States)

    Rutigliano, Sandra; Abraham, John A; Kenneally, Barry E; Zoga, Adam C; Nevalainen, Mika; Roedl, Johannes B

    Percutaneous computed tomography (CT)-guided needle biopsy has proven to be an efficacious method for sampling of many soft tissue lesions, especially deep-seated masses in the abdomen and pelvis. This study sought to test the potential for a novel steerable needle to improve localization and to reduce procedure duration and radiation dose compared with a conventional straight needle. A fresh, raw meat sample (lean bovine flank) was imbedded with cylindrical radiopaque and radiolucent obstacles designed to simulate vessels (radiolucent objects) and bones (radiopaque objects) on CT. A pit-containing olive (partially radiopaque) was imbedded beyond the obstacles to represent the target. Two sites on the surface of the meat were selected and marked to determine initial needle placement. Two radiologists with different levels of experience proceeded to position a straight needle and the steerable needle from each skin site to the target using CT guidance as efficiently as possible, avoiding the obstacles. The total positioning time, the number of CT scans required for positioning, and the number of repositioning events (partial withdrawal followed by advancement) were tracked for the straight and steerable needles. For the straight needle, total time to reach the target was 499 to 667 seconds (mean, 592 seconds); for the steerable needle, total time to reach the target was 281 to 343 seconds (mean, 309 seconds), on average, 48% lower. The number of CT scans needed for needle positioning averaged 6.25 for the straight needle and 3.5 for the steerable needle, which is 44% lower. Repositioning events (withdrawing and readvancing the needle) ranged from 3 to 10 for the straight needle (mean, 6.5) and 0 for the steerable needle. Using an in vitro model embedded with obstacles, the steerable needle performed better than a straight needle with regard to procedure time, needle repositioning events, and CT scans required for placement.

  16. Performance Accuracy of Hand-on-needle versus Hand-onsyringe Technique for Ultrasound-guided Regional Anesthesia Simulation for Emergency Medicine Residents

    Directory of Open Access Journals (Sweden)

    Brian Johnson

    2014-09-01

    Full Text Available Introduction: Ultrasound-guided nerve blocks (UGNB are increasingly used in emergency care. The hand-on-syringe (HS needle technique is ideally suited to the emergency department setting because it allows a single operator to perform the block without assistance. The HS technique is assumed to provide less exact needle control than the alternative two-operator hand-on-needle (HN technique; however this assumption has never been directly tested. The primary objective of this study was to compare accuracy of needle targeting under ultrasound guidance by emergency medicine (EM residents using HN and HS techniques on a standardized gelatinous simulation model. Methods: This prospective, randomized study evaluated task performance. We compared needle targeting accuracy using the HN and HS techniques. Each participant performed a set of structured needling maneuvers (both simple and difficult on a standardized partial-task simulator. We evaluated time to task completion, needle visualization during advancement, and accuracy of needle tip at targeting. Resident technique preference was assessed using a post-task survey. Results: We evaluated 60 tasks performed by 10 EM residents. There was no significant difference in time to complete the simple model (HN vs. HS, 18 seconds vs. 18 seconds, p=0.93, time to complete the difficult model (HN vs. HS, 56 seconds vs. 50 seconds, p=0.63, needle visualization, or needle tip targeting accuracy. Most residents (60% preferred the HS technique. Conclusion: For EM residents learning UGNBs, the HN technique was not associated with superior needle control. Our results suggest that the single-operator HS technique provides equivalent needle control when compared to the two-operator HN technique. [West J Emerg Med. 2014;15(6:641–646

  17. CT-guided core biopsy and percutaneous fiducial seed placement in the lung: Can these procedures be combined without an increase in complication rate or decrease in technical success?

    Energy Technology Data Exchange (ETDEWEB)

    Mendiratta-Lala, Mishal [Henry Ford Hospital, Department of Radiology, Abdominal Interventional Radiology, 2799 West Grand Blvd, Detroit, MI 48202 (United States); Sheiman, Robert, E-mail: rsheiman@bidmc.harvard.edu [Beth Israel Deaconess Hospital, Department of Radiology, Abdominal Imaging, One Deaconess Road, Boston, MA 02215 (United States); Brook, Olga R. [Beth Israel Deaconess Hospital, Department of Radiology, Abdominal Imaging, One Deaconess Road, Boston, MA 02215 (United States); Gourtsoyianni, Sofia [King' s College London, St Thomas’ Hospital, Lambeth Palace Road, SE1 7EH London (United Kingdom); Mahadevan, Anand [Beth Israel Deaconess Hospital, Radiation Oncology, One Deaconess Road, Boston, MA 02215 (United States); Siewert, Bettina [Beth Israel Deaconess Hospital, Department of Radiology, Abdominal Imaging, One Deaconess Road, Boston, MA 02215 (United States)

    2014-04-15

    Objective: To determine if concomitant CT-guided biopsy and percutaneous fiducial seed placement in the lung can be performed in a selective patient population without increased complication or decreased success rates compared to either procedure alone. Materials and methods: An IRB approved retrospective analysis of 285 consecutive patients that underwent CT-guided placement of fiducial seeds in the lung alone (N = 63), with concomitant core biopsy (N = 53) or only core biopsy (N = 169) was performed. Variables compared included: patient demographics, lesion size, depth from pleura, needle size, number of passes through pleura, number and size of core biopsies, number of seeds placed and technical success rates. Statistical analysis was performed using univariate and multivariate pair-wise comparisons. Results: A pathologic diagnosis of malignancy was confirmed in all cases undergoing seed placement alone and seed placement with concurrent biopsy, and in 144 of the biopsy alone lesions. On univariate analysis, major complication rates were similar for all three groups as were lesion size, depth, number of pleural passes, and technical success. Pair-wise comparisons of the remaining variables demonstrated a significant younger age and smaller needle size in the biopsy only group, and less minor complications in the fiducial only group. Overall there were 80/285 (28.1%) minor and 29/285 (10.2%) major complications. All major complications leading to admission consisted of either pneumothorax or hemothorax, while minor complications included asymptomatic stable or resolving pneumothoraces, transient hemoptysis or small hemothoraces. Conclusions: A combined procedure of percutaneous pulmonary core biopsy and stereotactic seed placement can be performed without additional risk of a major complication when compared to performing these separately.

  18. CT Scan-Guided Abrams' Needle Pleural Biopsy versus Ultrasound-Assisted Cutting Needle Pleural Biopsy for Diagnosis in Patients with Pleural Effusion: A Randomized, Controlled Trial.

    Science.gov (United States)

    Metintas, Muzaffer; Yildirim, Huseyin; Kaya, Tamer; Ak, Guntulu; Dundar, Emine; Ozkan, Ragip; Metintas, Selma

    2016-01-01

    Image-guided pleural biopsies, both using ultrasound (US) or computed tomography (CT), are important in the diagnosis of pleural disease. However, no consensus exists regarding which biopsy needles are appropriate for specific procedures. In this randomized, prospective study, we aimed to compare CT scan-guided pleural biopsy using an Abrams' needle (CT-ANPB) with US-assisted pleural biopsy using a cutting needle (US-CNPB) with respect to both diagnostic yield and safety. Between February 2009 and April 2013, 150 patients with exudative pleural effusion who could not be diagnosed by cytological analysis were included in the study. The patients were randomized into either the US-CNPB group or the CT-ANPB group. The two groups were compared in terms of diagnostic sensitivity and complications. Of the 150 patients enrolled in this study, 45 were diagnosed with malignant mesothelioma, 46 were diagnosed with metastatic pleural disease, 18 were diagnosed with pleural tuberculosis, 34 were diagnosed with benign pleural disease, and 7 were lost to follow-up. In the US-CNPB group, the diagnostic sensitivity was 66.7%, compared with 82.4% in the CT-ANPB group; the difference between the two groups was statistically significant (p = 0.029). The sensitivity of CT-ANPB increased to 93.7% for patients with a pleural thickness ≥1 cm. The complication rates were low and acceptable. The first diagnostic intervention that should be preferred in patients with pleural effusion and associated pleural thickening on a CT scan is CT-ANPB. US-CNPB should be used primarily in cases for which only pleural thickening but no pleural effusion is noted. © 2016 S. Karger AG, Basel.

  19. A needle guidance system for biopsy and therapy using two-dimensional ultrasound

    International Nuclear Information System (INIS)

    Bluvol, Nathan; Sheikh, Allison; Kornecki, Anat; Del Rey Fernandez, David; Downey, Donal; Fenster, Aaron

    2008-01-01

    Image-guided needle biopsies are currently used to provide a definitive diagnosis of breast cancer; however, difficulties in tumor targeting exist as the ultrasound (United States) scan plane and biopsy needle must remain coplanar throughout the procedure to display the actual needle tip position. The additional time associated with aligning and maintaining this coplanar relationship results in increased patient discomfort. Biopsy procedural efficiency is further hindered since needle pathway interpretation is often difficult, especially for needle insertions at large depths that usually require multiple reinsertions. The authors developed a system that would increase the speed and accuracy of current breast biopsy procedures using readily available two-dimensional (2D) US technology. This system is composed of a passive articulated mechanical arm that attaches to a 2D US transducer. The arm is connected to a computer through custom electronics and software, which were developed as an interface for tracking the positioning of the mechanical components in real time. The arm couples to the biopsy needle and provides visual guidance for the physician performing the procedure in the form of a real-time projected needle pathway overlay on an US image of the breast. An agar test phantom, with stainless steel targets interspersed randomly throughout, was used to validate needle trajectory positioning accuracy. The biopsy needle was guided by both the software and hardware components to the targets. The phantom, with the needle inserted and device decoupled, was placed in an x-ray stereotactic mammography (SM) machine. The needle trajectory and bead target locations were determined in three dimensions from the SM images. Results indicated a mean needle trajectory accuracy error of 0.75±0.42 mm. This is adequate to sample lesions that are <2 mm in diameter. Chicken tissue test phantoms were used to compare core needle biopsy procedure times between experienced radiologists

  20. Endoscopic ultrasound-guided fine-needle tissue acquisition - A review and update of literature

    Directory of Open Access Journals (Sweden)

    Benjamin Tharian

    2015-01-01

    Full Text Available Ever since the first endoscopic ultrasound-guided fine needle aspiration (FNA was done in 1992, the procedure has evolved to become an indispensable tool for tissue acquisition in patients with gastrointestinal tumors and periluminal lesions. With the growing evidence of neoadjuvant therapy and research into intratumoral therapy, the need to obtain tissue diagnosis for tumors is quite apparent. This review provides an overall perspective to the endosonographer on various issues that are a key for best practices in FNA, in addition to being an update for practicing experienced endosonographers.

  1. Augmented Reality-Guided Lumbar Facet Joint Injections.

    Science.gov (United States)

    Agten, Christoph A; Dennler, Cyrill; Rosskopf, Andrea B; Jaberg, Laurenz; Pfirrmann, Christian W A; Farshad, Mazda

    2018-05-08

    The aim of this study was to assess feasibility and accuracy of augmented reality-guided lumbar facet joint injections. A spine phantom completely embedded in hardened opaque agar with 3 ring markers was built. A 3-dimensional model of the phantom was uploaded to an augmented reality headset (Microsoft HoloLens). Two radiologists independently performed 20 augmented reality-guided and 20 computed tomography (CT)-guided facet joint injections each: for each augmented reality-guided injection, the hologram was manually aligned with the phantom container using the ring markers. The radiologists targeted the virtual facet joint and tried to place the needle tip in the holographic joint space. Computed tomography was performed after each needle placement to document final needle tip position. Time needed from grabbing the needle to final needle placement was measured for each simulated injection. An independent radiologist rated images of all needle placements in a randomized order blinded to modality (augmented reality vs CT) and performer as perfect, acceptable, incorrect, or unsafe. Accuracy and time to place needles were compared between augmented reality-guided and CT-guided facet joint injections. In total, 39/40 (97.5%) of augmented reality-guided needle placements were either perfect or acceptable compared with 40/40 (100%) CT-guided needle placements (P = 0.5). One augmented reality-guided injection missed the facet joint space by 2 mm. No unsafe needle placements occurred. Time to final needle placement was substantially faster with augmented reality guidance (mean 14 ± 6 seconds vs 39 ± 15 seconds, P Augmented reality-guided facet joint injections are feasible and accurate without potentially harmful needle placement in an experimental setting.

  2. Comparison of needle aspiration and vacuum-assisted biopsy in the ultrasound-guided drainage of lactational breast abscesses

    International Nuclear Information System (INIS)

    Kang, Yun Dan; Kim, You Me

    2016-01-01

    The purpose of this study was to compare needle aspiration and vacuum-assisted biopsy in the ultrasound-guided treatment of lactational breast abscesses. Between January 2005 and December 2014, a total of 74 patients presented with lactational breast abscesses. Thirty of these patients underwent treatment with antibioticsalone, while the remaining 44 lactating women with breast abscesses were treated with needle aspiration (n=25) or vacuum-assisted biopsy (n=19). Age, duration of lactation, abscess diameter, pus culture results, the number of interventions, the healing time, and the cure rate were reviewed and compared between these two groups. The Student's t test and the chi-square test were used to compare the variables. No significant difference was found in the cure rate between the needle aspiration group (22/25, 88%) and the vacuum-assisted biopsy group (18/19, 94.7%) (P=0.441). However, the mean healing time was significantly shorter in the vacuum-assisted biopsy group (6.7 days) than in the needle aspiration group (9.0 days) (P=0.001). Vacuum-assisted biopsy is a viable option for the management of lactational breast abscesses and was found to lead to a shorter healing time than needle aspiration. However, further study is necessary to establish the clinical efficacy of vacuum-assisted biopsy in the management of lactational breast abscesses

  3. Comparison of needle aspiration and vacuum-assisted biopsy in the ultrasound-guided drainage of lactational breast abscesses

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Yun Dan; Kim, You Me [Dankook University College of Medicine, Cheonan (Korea, Republic of)

    2016-03-15

    The purpose of this study was to compare needle aspiration and vacuum-assisted biopsy in the ultrasound-guided treatment of lactational breast abscesses. Between January 2005 and December 2014, a total of 74 patients presented with lactational breast abscesses. Thirty of these patients underwent treatment with antibioticsalone, while the remaining 44 lactating women with breast abscesses were treated with needle aspiration (n=25) or vacuum-assisted biopsy (n=19). Age, duration of lactation, abscess diameter, pus culture results, the number of interventions, the healing time, and the cure rate were reviewed and compared between these two groups. The Student's t test and the chi-square test were used to compare the variables. No significant difference was found in the cure rate between the needle aspiration group (22/25, 88%) and the vacuum-assisted biopsy group (18/19, 94.7%) (P=0.441). However, the mean healing time was significantly shorter in the vacuum-assisted biopsy group (6.7 days) than in the needle aspiration group (9.0 days) (P=0.001). Vacuum-assisted biopsy is a viable option for the management of lactational breast abscesses and was found to lead to a shorter healing time than needle aspiration. However, further study is necessary to establish the clinical efficacy of vacuum-assisted biopsy in the management of lactational breast abscesses.

  4. Malignant-looking thyroid nodules with size reduction: Core needle biopsy results

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ha Young; Baek, Jung Hwan; Ha, Eun Jun; Park, Jee Won; Lee, Jeong Hyun; Song, Dong Eun; Shong, Young Kee [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2016-08-15

    The aim of this study was to evaluate whether malignant-looking thyroid nodules with size reduction were malignant or not. From November 2010 to July 2011, we retrospectively enrolled 16 patients with 16 nodules (11 females and five males; mean age, 55 years) who underwent core needle biopsy (CNB), and whose thyroid nodules had malignant ultrasonographic (US) features, although they showed size reduction (>20% decrease in maximum diameter) during the follow-up period (mean, 37±27 months). The histologic findings of the CNB specimen were reviewed and correlated with the US findings. US studies were analyzed for their internal content, shape, margin, echogenicity, the presence of microcalcification and macrocalcification, inner isoechoic rim, and low-echoic halo. All nodules were confirmed as benign by CNB. Pathologic analysis was available for 12 CNB specimens. US imaging showed central hypoechogenicity or marked hypoechogenicity in all cases and a peripheral isoechoic rim in 15 nodules. US-pathologic correlation showed that the central hypoechoic area was primarily composed of fibrosis (12/12) and hemorrhage (8/12) and that the isoechoic rim was composed of follicular cells. In our study, the CNB results of all of the malignant-looking thyroid nodules with size reduction were benign and were primarily composed of internal fibrosis and hemorrhage. Understanding these US and pathologic features could prevent repeated fine-needle aspiration or unnecessary diagnostic surgery.

  5. The research of knitting needle status monitoring setup

    Science.gov (United States)

    Liu, Lu; Liao, Xiao-qing; Zhu, Yong-kang; Yang, Wei; Zhang, Pei; Zhao, Yong-kai; Huang, Hui-jie

    2013-09-01

    In textile production, quality control and testing is the key to ensure the process and improve the efficiency. Defect of the knitting needles is the main factor affecting the quality of the appearance of textiles. Defect detection method based on machine vision and image processing technology is universal. This approach does not effectively identify the defect generated by damaged knitting needles and raise the alarm. We developed a knitting needle status monitoring setup using optical imaging, photoelectric detection and weak signal processing technology to achieve real-time monitoring of weaving needles' position. Depending on the shape of the knitting needle, we designed a kind of Glass Optical Fiber (GOF) light guides with a rectangular port used for transmission of the signal light. To be able to capture the signal of knitting needles accurately, we adopt a optical 4F system which has better imaging quality and simple structure and there is a rectangle image on the focal plane after the system. When a knitting needle passes through position of the rectangle image, the reflected light from needle surface will back to the GOF light guides along the same optical system. According to the intensity of signals, the computer control unit distinguish that the knitting needle is broken or curving. The experimental results show that this system can accurately detect the broken needles and the curving needles on the knitting machine in operating condition.

  6. Precision of MR-guided needle placement. Experimental results; Praezision der Lokalisierbarkeit einer Punktionsnadel in der MRT. Experimentelle Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Langen, H.J. [Roentgenabteilung der Missionsaerztlichen Klinik Wuerzburg (Germany); Stuetzer, H. [Inst. fuer Medizinische Statistik, Informatik und Epidemiologie der Univ. zu Koeln (Germany); Kugel, H.; Krug, B.; Hesselmann, V.; Schulte, O.; Walter, C.; Landwehr, P. [Inst. und Poliklinik fuer Radiologische Diagnostik der Univ. zu Koeln (Germany)

    2000-11-01

    To estimate the accuracy of the determination of tip position of MR compatible biopsy needles based on signal voids and artifacts in MR guided biopsies. Method: In a nylon grid phantom an MR compatible 18G needle (E-Z-EM) was measured in a 1.0 T imager using TSE- and FFE-sequences of 20 s and 40 s duration in 34 different orientations of needle versus B{sub 0}, frequency and slice selection gradient. 4 radiologists with no experience in the evaluation of signal void artifacts estimated the needle tip positions from needle tip artifacts. The readers determined the needle tip before and after a 15 minute training session based on high resolution images with explanation of size and shape of specific artifacts of biopsy needles in 12 different orthogonal or parallel orientations to B{sub 0} and frequency encoding gradient that are possible if the needle lies parallel to the slice, i.e. orthogonal to the slice selection gradient. The values obtained before and after the training session were compared to the real position of the needle tip. Results: Mean distance of actual needle tip and tip position as determined from images was 1.8{+-}2.3 mm in TSE- versus 2.5{+-}1.2 mm in FFE-images, with the needle length overestimated. After a 15 minute training session the positioning error decreased significantly to 0.2{+-}1.8 mm for TSE-sequences and to 1.0{+-}1.8 mm for FFE-sequences. A higher accuracy of tip localization was obtained with TSE sequences. Conclusion: In MR guided biopsies using FFE- and TSE-sequences the needle position can be more accurately determined if the reader is familiar with the 12 orthogonal or parallel positions of the needle with respect to B{sub 0} and frequency encoding gradient and the corresponding artifacts. (orig.) [German] Abschaetzung der Praezision, mit der die Spitze einer MR-kompatiblen Biopsienadel anhand ihrer Artefakte bestimmt werden kann. Methode: Experimentell wurde eine MR-kompatible 18 G Biopsienadel (E-Z-EM) in einem 1,0 Tesla MR

  7. Benign core biopsy of probably benign breast lesions 2 cm or larger: correlation with excisional biopsy and long-term follow-up

    OpenAIRE

    Jung, Hyun Kyung; Moon, Hee Jung; Kim, Min Jung; Kim, Eun-Kyung

    2014-01-01

    Purpose: To evaluate the accuracy of benign core biopsy of probably benign breast lesions (category 3) 2 cm or larger on the basis of excisional biopsy and long-term follow-up. Methods: We retrospectively reviewed 146 category 3 lesions in 146 patients 2 cm or larger which were diagnosed as benign by ultrasound (US)-guided core biopsy. Patients were initially diagnosed as benign at core needle biopsy and then followed up with excisional biopsy (surgical excision, n=91; US-guided vacuum assist...

  8. Thyroid nodules with isolated macrocalcification: Malignancy and diagnostic efficacy of fine-needle aspiration and core needle biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Na, Dong Gyu; Kim, Dae Sik; Kim, Soo Jin [Dept. of Radiology, Human Medical Imaging and Intervention Center, Seoul (Korea, Republic of); Ryoo, Jae Wook [Dept. of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Jung, So Lyung [Dept. of Radiology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of)

    2016-07-15

    This study was performed to determine the malignancy risk of thyroid nodules with isolated macrocalcification and to evaluate the diagnostic efficacy of fine-needle aspiration (FNA) and core needle biopsy (CNB). From May 2008 to December 2014, a total of 44 patients with isolated macrocalcifications were enrolled from 4,081 consecutive patients who underwent FNA or CNB at a single institution. We assessed the malignancy risk of nodules with isolated macrocalcification. We compared the diagnostic results between FNA and CNB, and the diagnostic efficacy of each procedure was evaluated by the rate of inconclusive results. We compared the diagnostic performance for malignancy between FNA and CNB with a criterion of malignant or atypia/follicular lesion of undetermined significance (indeterminate) diagnostic results. We investigated whether the ultrasonographic feature of isolated macrocalcification was predictive of malignancy. The malignancy risk of nodules with isolated macrocalcification was 16.1% in 31 nodules with final diagnoses and 11.4% in all nodules. CNB demonstrated a significantly lower rate of nondiagnostic and inconclusive results than FNA (7.7% vs. 53.8%, P=0.002 and 15.4% vs. 57.7%, P=0.003, respectively) in 26 nodules that underwent both FNA and CNB. CNB showed a marginally higher diagnostic performance for identifying malignancy than FNA (P=0.067). The ultrasonographic features of the anterior margin of isolated macrocalcification were not predictive of malignancy (P>0.999). Thyroid nodules with isolated macrocalcification had a low to intermediate malignancy risk and should not be considered benign nodules. CNB showed a higher diagnostic efficacy than FNA in these nodules.

  9. Thyroid nodules with isolated macrocalcification: Malignancy and diagnostic efficacy of fine-needle aspiration and core needle biopsy

    International Nuclear Information System (INIS)

    Na, Dong Gyu; Kim, Dae Sik; Kim, Soo Jin; Ryoo, Jae Wook; Jung, So Lyung

    2016-01-01

    This study was performed to determine the malignancy risk of thyroid nodules with isolated macrocalcification and to evaluate the diagnostic efficacy of fine-needle aspiration (FNA) and core needle biopsy (CNB). From May 2008 to December 2014, a total of 44 patients with isolated macrocalcifications were enrolled from 4,081 consecutive patients who underwent FNA or CNB at a single institution. We assessed the malignancy risk of nodules with isolated macrocalcification. We compared the diagnostic results between FNA and CNB, and the diagnostic efficacy of each procedure was evaluated by the rate of inconclusive results. We compared the diagnostic performance for malignancy between FNA and CNB with a criterion of malignant or atypia/follicular lesion of undetermined significance (indeterminate) diagnostic results. We investigated whether the ultrasonographic feature of isolated macrocalcification was predictive of malignancy. The malignancy risk of nodules with isolated macrocalcification was 16.1% in 31 nodules with final diagnoses and 11.4% in all nodules. CNB demonstrated a significantly lower rate of nondiagnostic and inconclusive results than FNA (7.7% vs. 53.8%, P=0.002 and 15.4% vs. 57.7%, P=0.003, respectively) in 26 nodules that underwent both FNA and CNB. CNB showed a marginally higher diagnostic performance for identifying malignancy than FNA (P=0.067). The ultrasonographic features of the anterior margin of isolated macrocalcification were not predictive of malignancy (P>0.999). Thyroid nodules with isolated macrocalcification had a low to intermediate malignancy risk and should not be considered benign nodules. CNB showed a higher diagnostic efficacy than FNA in these nodules

  10. Histopathological correlation of a group of suspicious breast lesions of malignancy valued by ultrasound categorized by BIRADS classification, to which were realized core needle biopsy through sonographic guide, at the Servicio de Radiologia e Imagenes Medicas of the Hospital Mexico, in the period from January to December 2012

    International Nuclear Information System (INIS)

    Castro Escalante, Ruben; Salazar Blanco, Esteban

    2014-01-01

    A histological correlation is established through a transversal study of a group of suspected breast lesions of malignancy valued by ultrasound. Injuries were categorized by BIRADS system and subjected to ultrasound-guided core needle biopsy, at the Servicio de Radiologia e Imagenes Medicas of the Hospital Mexico, from January to December 2012, in order to establish casuistic and comparison with studies of other latitudes. The 99 cases analyzed have complied with inclusion criteria, where the variables have been: the age of the patient, the type of injury, laterality and location of the lesion, the sonographic characteristics of the injury, BIRADS of the lesion, the professional who has performed the biopsy, the number and quality of the sample and histological diagnostic of the injury. The results of the study have found that the average age has been 53.2 years and the group of 40-69 years has had more cases of breast lesions, the highest percentage of lesions were biopsied by an assistant or resident with residents with your assistant, left laterality has predominated (p<0.05), the upper outer quadrant has been the most frequent, the solid nodule of regular borders of 1,2 cm of diameter has predominated in the study, 4 samples per lesion have been the most frequent, the adequate quality of the sample has been of the 95%, BIRADS IVA lesions have predominated, malignant lesion most frequent has been the N2 infiltrating ductal carcinoma and the benign has been the fibroadenoma. The guidelines established by BIRADS system have achieved better handling and behavior of breast lesions, as well as adhere to the techniques described of the procedure of ultrasound-guided core needle biopsy. This last procedure has been minimally invasive of high precision, according to the results obtained of the study. (author) [es

  11. Transbronchial needle aspiration with a new electromagnetically-tracked TBNA needle

    Science.gov (United States)

    Choi, Jae; Popa, Teo; Gruionu, Lucian

    2009-02-01

    Transbronchial needle aspiration (TBNA) is a common method used to collect tissue for diagnosis of different chest diseases and for staging lung cancer, but the procedure has technical limitations. These limitations are mostly related to the difficulty of accurately placing the biopsy needles into the target mass. Currently, pulmonologists plan TBNA by examining a number of Computed Tomography (CT) scan slices before the operation. Then, they manipulate the bronchoscope down the respiratory track and blindly direct the biopsy. Thus, the biopsy success rate is low. The diagnostic yield of TBNA is approximately 70 percent. To enhance the accuracy of TBNA, we developed a TBNA needle with a tip position that can be electromagnetically tracked. The needle was used to estimate the bronchoscope's tip position and enable the creation of corresponding virtual bronchoscopic images from a preoperative CT scan. The TBNA needle was made with a flexible catheter embedding Wang Transbronchial Histology Needle and a sensor tracked by electromagnetic field generator. We used Aurora system for electromagnetic tracking. We also constructed an image-guided research prototype system incorporating the needle and providing a user-friendly interface to assist the pulmonologist in targeting lesions. To test the feasibility of the accuracy of the newly developed electromagnetically-tracked needle, a phantom study was conducted in the interventional suite at Georgetown University Hospital. Five TBNA simulations with a custom-made phantom with a bronchial tree were performed. The experimental results show that our device has potential to enhance the accuracy of TBNA.

  12. Benign core biopsy of probably benign breast lesions 2 cm or larger: correlation with excisional biopsy and long-term follow-up

    International Nuclear Information System (INIS)

    Jung, Hyun Kyung; Moon, Hee Jung; Kim, Min Jung; Kim, Eun Kyung

    2014-01-01

    To evaluate the accuracy of benign core biopsy of probably benign breast lesions (category 3) 2 cm or larger on the basis of excisional biopsy and long-term follow-up. We retrospectively reviewed 146 category 3 lesions in 146 patients 2 cm or larger which were diagnosed as benign by ultrasound (US)-guided core biopsy. Patients were initially diagnosed as benign at core needle biopsy and then followed up with excisional biopsy (surgical excision, n=91; US-guided vacuum assisted excision, n=35) or breast ultrasonography (n=20). Of the 126 patients who underwent surgical excision or US-guided vacuum-assisted excision, 114 patients were diagnosed with benign lesions, 10 patients with borderline lesions (benign phyllodes tumor), and two patients with malignant phyllodes tumors. The probabilities of lesions being benign, borderline and malignant were 91.8% (134/146), 6.8% (10/146), and 1.4% (2/146), respectively. Of 13 patients who had growing masses on follow-up ultrasonography, three (23.1%) were non-benign (two benign phyllodes tumors and one malignant phyllodes tumor). US-guided core needle biopsy of probably benign breast mass 2 cm or larger was accurate (98.6%) enough to rule out malignancy. But, it was difficult to rule out borderline lesions even when they were diagnosed as benign.

  13. Risk factors for severity of pneumothorax after CT-guided percutaneous lung biopsy using the single-needle method.

    Science.gov (United States)

    Kakizawa, Hideaki; Toyota, Naoyuki; Hieda, Masashi; Hirai, Nobuhiko; Tachikake, Toshihiro; Matsuura, Noriaki; Oda, Miyo; Ito, Katsuhide

    2010-09-01

    The purpose of this study is to evaluate the risk factors for the severity of pneumothorax after computed tomography (CT)-guided percutaneous lung biopsy using the single-needle method. We reviewed 91 biopsy procedures for 90 intrapulmonary lesions in 89 patients. Patient factors were age, sex, history of ipsilateral lung surgery and grade of emphysema. Lesion factors were size, location and pleural contact. Procedure factors were position, needle type, needle size, number of pleural punctures, pleural angle, length of needle passes in the aerated lung and number of harvesting samples. The severity of pneumothorax after biopsy was classified into 4 groups: "none", "mild", "moderate" and "severe". The risk factors for the severity of pneumothorax were determined by multivariate analyzing of the factors derived from univariate analysis. Pneumothorax occurred in 39 (43%) of the 91 procedures. Mild, moderate, and severe pneumothorax occurred in 24 (26%), 8 (9%) and 7 (8%) of all procedures, respectively. Multivariate analysis showed that location, pleural contact, number of pleural punctures and number of harvesting samples were significantly associated with the severity of pneumothorax (p < 0.05). In conclusion, lower locations and non-pleural contact lesions, increased number of pleural punctures and increased number of harvesting samples presented a higher severity of pneumothorax.

  14. Risk factors for severity of pneumothorax after CT-guided percutaneous lung biopsy using the single-needle method

    International Nuclear Information System (INIS)

    Kakizawa, Hideaki; Hieda, Masashi; Oda, Miyo; Toyota, Naoyuki; Hirai, Nobuhiko; Tachikake, Toshihiro; Matsuura, Noriaki; Ito, Katsuhide

    2010-01-01

    The purpose of this study is to evaluate the risk factors for the severity of pneumothorax after computed tomography (CT)-guided percutaneous lung biopsy using the single-needle method. We reviewed 91 biopsy procedures for 90 intrapulmonary lesions in 89 patients. Patient factors were age, sex, history of ipsilateral lung surgery and grade of emphysema. Lesion factors were size, location and pleural contact. Procedure factors were position, needle type, needle size, number of pleural punctures, pleural angle, length of needle passes in the aerated lung and number of harvesting samples. The severity of pneumothorax after biopsy was classified into 4 groups: 'none', 'mild', 'moderate' and 'severe'. The risk factors for the severity of pneumothorax were determined by multivariate analyzing of the factors derived from univariate analysis. Pneumothorax occurred in 39 (43%) of the 91 procedures. Mild, moderate, and severe pneumothorax occurred in 24 (26%), 8 (9%) and 7 (8%) of all procedures, respectively. Multivariate analysis showed that location, pleural contact, number of pleural punctures and number of harvesting samples were significantly associated with the severity of pneumothorax (p<0.05). In conclusion, lower locations and non-pleural contact lesions, increased number of pleural punctures and increased number of harvesting samples presented a higher severity of pneumothorax. (author)

  15. Application of CT-guided percutaneous thyroid biopsy in basic study of interventional therapy for Graves disease

    International Nuclear Information System (INIS)

    Yi Genfa; Zhao Wei; Hu Jihong; Jin Cangzheng; Yang Huiying

    2007-01-01

    Objective: To evaluate the value of application of CT-guided percutaneous thyroid biopsy in basic study of interventional treatment for Graves disease. Methods: Fifteen patients of hyperthyroidism caused by Graves' disease had been undertaken transcathter arterial embolizsation with PVA micropheres including 52 core needle biopsy(CNB)of pre-or post-interventional procedure. All procedures were divided into 2 groups according to the size of the thyroid enlargement: (1) II degree enlargement (n=19)under palpation puncture. (2) No enlargement or under II degree enlargement (n=33)with palpation and CT-guided puncture. Results: In group (1), 17 of the 19 procedures with palpation puncture were succeeded, reaching a successful rate of 89.5%. For group (2), the successful rate of CT-guided puncture was 91.7%. The difference between the successful rate of two groups showed statistical significance (P<0.05). No complication occurred during procedures in all cases. Conclusions: CT-guided thyroid core needle biopsy is an accurate, safe and high successful procedure providing the basic study for post-interventional treatment of Graves disease. (authors)

  16. MR-guided preoperative localization and percutaneous core biopsy of suspicious breast lesions - experience on the vertically open 0.5 T system

    International Nuclear Information System (INIS)

    Schneider, J.P.; Schulz, T.; Rueger, S.; Schmidt, F.; Kahn, T.; Leinung, S.; Briest, S.

    2002-01-01

    Purpose. To evaluate the feasibility of performing breast interventions in a vertically open 0.5 T MR system (SIGNA SP/i, GE Medical Systems). To develop fitted equipment and to establish preoperative wire localization and percutaneous breast core biopsy as clinical routine procedures. Patients and methods. Initially, we applied a localization method with the patient placed in a sitting position in 31 cases using a single loop coil and a self-developed fixation device. Subsequently, 46 wire localizations and 28 percutaneous core biopsies were carried out in prone patient position using an open breast coil with an integrated biopsy device. The used instruments were either MR-compatible (18 G biopsy needle and localization wire, 14 G coaxial needle, prototype of a 16 G double-shoot gun) or MR-safe (double-shoot gun with 16 G needle). Results. After biopsy we found the needle tip (18 G for a wire localization and 14 G for a percutaneous core biopsy, respectively) placed either within or close to the lesions ( [de

  17. Does imprint cytology improve the accuracy of transrectal prostate needle biopsy?

    Science.gov (United States)

    Sayar, Hamide; Bulut, Burak Besir; Bahar, Abdulkadir Yasir; Bahar, Mustafa Remzi; Seringec, Nurten; Resim, Sefa; Çıralık, Harun

    2015-02-01

    To evaluate the accuracy of imprint cytology of core needle biopsy specimens in the diagnosis of prostate cancer. Between December 24, 2011 and May 9, 2013, patients with an abnormal DRE and/or serum PSA level of >2.5 ng/mL underwent transrectal prostate needle biopsy. Samples with positive imprint cytology but negative initial histologic exam underwent repeat sectioning and histological examination. 1,262 transrectal prostate needle biopsy specimens were evaluated from 100 patients. Malignant imprint cytology was found in 236 specimens (18.7%), 197 (15.6%) of which were confirmed by histologic examination, giving an initial 3.1% (n = 39) rate of discrepant results by imprint cytology. Upon repeat sectioning and histologic examination of these 39 biopsy samples, 14 (1.1% of the original specimens) were then diagnosed as malignant, 3 (0.2%) as atypical small acinar proliferation (ASAP), and 5 (0.4%) as high-grade prostatic intraepithelial neoplasia (HGPIN). Overall, 964 (76.4%) specimens were negative for malignancy by imprint cytology. Seven (0.6%) specimens were benign by cytology but malignant cells were found on histological evaluation. On imprint cytology examination, nonmalignant but abnormal findings were seen in 62 specimens (4.9%). These were all due to benign processes. After reexamination, the accuracy, sensitivity, specificity, positive predictive value, negative predictive value, false-positive rate, false-negative rate of imprint preparations were 98.1, 96.9, 98.4, 92.8, 99.3, 1.6, 3.1%, respectively. Imprint cytology is valuable tool for evaluating TRUS-guided core needle biopsy specimens from the prostate. Use of imprint cytology in combination with histopathology increases diagnostic accuracy when compared with histopathologic assessment alone. © 2014 Wiley Periodicals, Inc.

  18. Technical aspects of endoscopic ultrasound (EUS)-guided sampling in gastroenterology: European Society of Gastrointestinal Endoscopy (ESGE) Technical Guideline - March 2017.

    Science.gov (United States)

    Polkowski, Marcin; Jenssen, Christian; Kaye, Philip; Carrara, Silvia; Deprez, Pierre; Gines, Angels; Fernández-Esparrach, Gloria; Eisendrath, Pierre; Aithal, Guruprasad P; Arcidiacono, Paolo; Barthet, Marc; Bastos, Pedro; Fornelli, Adele; Napoleon, Bertrand; Iglesias-Garcia, Julio; Seicean, Andrada; Larghi, Alberto; Hassan, Cesare; van Hooft, Jeanin E; Dumonceau, Jean-Marc

    2017-10-01

    For routine EUS-guided sampling of solid masses and lymph nodes (LNs) ESGE recommends 25G or 22G needles (high quality evidence, strong recommendation); fine needle aspiration (FNA) and fine needle biopsy (FNB) needles are equally recommended (high quality evidence, strong recommendation).When the primary aim of sampling is to obtain a core tissue specimen, ESGE suggests using 19G FNA or FNB needles or 22G FNB needles (low quality evidence, weak recommendation).ESGE recommends using 10-mL syringe suction for EUS-guided sampling of solid masses and LNs with 25G or 22G FNA needles (high quality evidence, strong recommendation) and other types of needles (low quality evidence, weak recommendation). ESGE suggests neutralizing residual negative pressure in the needle before withdrawing the needle from the target lesion (moderate quality evidence, weak recommendation).ESGE does not recommend for or against using the needle stylet for EUS-guided sampling of solid masses and LNs with FNA needles (high quality evidence, strong recommendation) and suggests using the needle stylet for EUS-guided sampling with FNB needles (low quality evidence, weak recommendation).ESGE suggests fanning the needle throughout the lesion when sampling solid masses and LNs (moderate quality evidence, weak recommendation).ESGE equally recommends EUS-guided sampling with or without on-site cytologic evaluation (moderate quality evidence, strong recommendation). When on-site cytologic evaluation is unavailable, ESGE suggests performance of three to four needle passes with an FNA needle or two to three passes with an FNB needle (low quality evidence, weak recommendation).For diagnostic sampling of pancreatic cystic lesions without a solid component, ESGE suggests emptying the cyst with a single pass of a 22G or 19G needle (low quality evidence, weak recommendation). For pancreatic cystic lesions with a solid component, ESGE suggests sampling of the solid component using the same technique as in the

  19. Adenomyoepithelioma of the breast with hemorrhagic change diagnosed as papiloma on core needle biopsy: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Kyung Sun; Kim, Ji Young; Kim, Soung Hee; Bae, Kyung Eun; Lee, Ji Hae; Kang, Mi Jin; Jeong, Myeong Ja; Kim, Soo Hyun; Kim, Jae Hyung [Dept. of Radiology, Sanggye Paik Hospital, Inje University College of Medicine, Seoul (Korea, Republic of)

    2016-11-15

    Adenomyoepithelioma (AME) is a rare disease entity that represents biphasic proliferation of ductal epithelial and myoepithelial cells. AME can be confused with other neoplasms including malignancy because AME has various cytologic characteristics and nonspecific radiologic features. We describe an unusual AME with hemorrhagic change that was diagnosed as papilloma on core needle biopsy three times previously. The imaging features of AME are also discussed here.

  20. Assessment of bone biopsy needles for sample size, specimen quality and ease of use

    International Nuclear Information System (INIS)

    Roberts, C.C.; Liu, P.T.; Morrison, W.B.; Leslie, K.O.; Carrino, J.A.; Lozevski, J.L.

    2005-01-01

    To assess whether there are significant differences in ease of use and quality of samples among several bone biopsy needles currently available. Eight commonly used, commercially available bone biopsy needles of different gauges were evaluated. Each needle was used to obtain five consecutive samples from a lamb lumbar pedicle. Subjective assessment of ease of needle use, ease of sample removal from the needle and sample quality, before and after fixation, was graded on a 5-point scale. The number of attempts necessary to reach a 1 cm depth was recorded. Each biopsy specimen was measured in the gross state and after fixation. The RADI Bonopty 15 g and Kendall Monoject J-type 11 g needles were rated the easiest to use, while the Parallax Core-Assure 11 g and the Bard Ostycut 16 g were rated the most difficult. Parallax Core-Assure and Kendall Monoject needles had the highest quality specimen in the gross state; Cook Elson/Ackerman 14 g and Bard Ostycut 16 g needles yielded the lowest. The MD Tech without Trap-Lok 11 g needle had the highest quality core after fixation, while the Bard Ostycut 16 g had the lowest. There was a significant difference in pre-fixation sample length between needles (P<0.0001), despite acquiring all cores to a standard 1 cm depth. Core length and width decrease in size by an average of 28% and 42% after fixation. Bone biopsy needles vary significantly in performance. Detailed knowledge of the strengths and weaknesses of different needles is important to make an appropriate selection for each individual's practice. (orig.)

  1. A Case of Bilateral Acute Calcific Tendinitis of the Gluteus Medius, Treated by Ultrasound-guided Needle Lavage and Corticosteroid Injection

    OpenAIRE

    Vereecke, Elke; Mermuys, Koen; Casselman, Jan

    2015-01-01

    Calcium hydroxyapatite deposition disease is a common pathology, most frequently located in the rotator cuff tendons of the shoulder, for which different therapeutic approaches are used. Ultrasound guided needle lavage and injection of anesthetic/corticosteroid is a well-known and extensively described treatment for calcific tendinits of the rotator cuff. We present a case of bilateral calcific tendinitis of the gluteus medius tendon, both sides successfully treated using ultrasound guided ne...

  2. Improving needle tip identification during ultrasound-guided procedures in anaesthetic practice

    NARCIS (Netherlands)

    Scholten, H.J.; Pourtaherian, A.; Mihajlovic, N.; Korsten, H.; Bouwman, R.A.

    2017-01-01

    Ultrasound guidance is becoming standard practice for needle-based interventions in anaesthetic practice, such as vascular access and peripheral nerve blocks. However, difficulties in aligning the needle and the transducer can lead to incorrect identification of the needle tip, possibly damaging

  3. Percutaneous tenotomy: development of a novel, percutaneous, ultrasound-guided needle-cutting technique for division of tendons and other connective tissue structures

    International Nuclear Information System (INIS)

    Hopkins, James; Sampson, Matthew

    2014-01-01

    A variety of surgical procedures derive therapeutic benefit from the division of retinacular, ligamentous or tendinous structures. Examples include carpal tunnel release for median nerve impingement, annular pulley release for trigger finger and tendon division for spastic muscular contractures. Here, using an animal cadaveric model, we describe the first steps in determining the feasibility of a novel, percutaneous, ultrasound-guided needle-cutting technique to achieve the same ends. The technique we describe involves the creation of an effective needle tenotomy device via a simple modification to an 18G coaxial, beveled needle. The technique holds promise for the development of a minimally invasive alternative approach that utilises readily available technology and equipment with minimisation of morbidity and cost associated with open procedures.

  4. What is the added value of combined core biopsy and fine needle aspiration in the diagnostic process of renal tumours?

    NARCIS (Netherlands)

    Barwari, K.; Kümmerlin, I.P.E.D.; Ten Kate, F.J.; Algaba, F.; Trias, I.; Wijkstra, H.; Rosette, de la J.J.M.C.H.; Laguna, M.P.

    2013-01-01

    Purpose Non-diagnostic results still hinder the routine use of core biopsy (CB) and fine needle aspiration (FNA) in the diagnostic process of renal tumours. Furthermore, substantial interobserver variability has been reported. We assessed the added value of combining the results of CB and FNA by

  5. What is the added value of combined core biopsy and fine needle aspiration in the diagnostic process of renal tumours?

    NARCIS (Netherlands)

    Barwari, K.; Kummerlin, I. P.; ten Kate, F. J.; Algaba, F.; Trias, I.; Wijkstra, H.; de la Rosette, J. J.; Laguna, P.

    2013-01-01

    Non-diagnostic results still hinder the routine use of core biopsy (CB) and fine needle aspiration (FNA) in the diagnostic process of renal tumours. Furthermore, substantial interobserver variability has been reported. We assessed the added value of combining the results of CB and FNA by five

  6. Core management and fuel handling for nuclear power plants. Safety guide

    International Nuclear Information System (INIS)

    2004-01-01

    This Safety Guide supplements and elaborates upon the safety requirements for core management and fuel handling that are presented in Section 5 of the Safety Requirements publication on the operation of nuclear power plants. The present publication supersedes the IAEA Safety Guide on Safety Aspects of Core Management and Fuel Handling, issued in 1985 as Safety Series No. 50-SG-010. It is also related to the Safety Guide on the Operating Organization for Nuclear Power Plants, which identifies fuel management as one of the various functions to be performed by the operating organization. The purpose of this Safety Guide is to provide recommendations for core management and fuel handling at nuclear power plants on the basis of current international good practice. The present Safety Guide addresses those aspects of fuel management activities that are necessary in order to allow optimum reactor core operation without compromising the limits imposed by the design safety considerations relating to the nuclear fuel and the plant as a whole. In this publication, 'core management' refers to those activities that are associated with fuel management in the core and reactivity control, and 'fuel handling' refers to the movement, storage and control of fresh and irradiated fuel. Fuel management comprises both core management and fuel handling. This Safety Guide deals with fuel management for all types of land based stationary thermal neutron power plants. It describes the safety objectives of core management, the tasks that have to be accomplished to meet these objectives and the activities undertaken to perform those tasks. It also deals with the receipt of fresh fuel, storage and handling of fuel and other core components, the loading and unloading of fuel and core components, and the insertion and removal of other reactor materials. In addition, it deals with loading a transport container with irradiated fuel and its preparation for transport off the site. Transport

  7. Core management and fuel handling for nuclear power plants. Safety guide

    International Nuclear Information System (INIS)

    2002-01-01

    This Safety Guide supplements and elaborates upon the safety requirements for core management and fuel handling that are presented in Section 5 of the Safety Requirements publication on the operation of nuclear power plants. The present publication supersedes the IAEA Safety Guide on Safety Aspects of Core Management and Fuel Handling, issued in 1985 as Safety Series No. 50-SG-010. It is also related to the Safety Guide on the Operating Organization for Nuclear Power Plants, which identifies fuel management as one of the various functions to be performed by the operating organization. The purpose of this Safety Guide is to provide recommendations for core management and fuel handling at nuclear power plants on the basis of current international good practice. The present Safety Guide addresses those aspects of fuel management activities that are necessary in order to allow optimum reactor core operation without compromising the limits imposed by the design safety considerations relating to the nuclear fuel and the plant as a whole. In this publication, 'core management' refers to those activities that are associated with fuel management in the core and reactivity control, and 'fuel handling' refers to the movement, storage and control of fresh and irradiated fuel. Fuel management comprises both core management and fuel handling. This Safety Guide deals with fuel management for all types of land based stationary thermal neutron power plants. It describes the safety objectives of core management, the tasks that have to be accomplished to meet these objectives and the activities undertaken to perform those tasks. It also deals with the receipt of fresh fuel, storage and handling of fuel and other core components, the loading and unloading of fuel and core components, and the insertion and removal of other reactor materials. In addition, it deals with loading a transport container with irradiated fuel and its preparation for transport off the site. Transport

  8. Comparison of needle aspiration and vacuum-assisted biopsy in the ultrasound-guided drainage of lactational breast abscesses

    Directory of Open Access Journals (Sweden)

    Yun-Dan Kang

    2016-04-01

    Full Text Available Purpose: The purpose of this study was to compare needle aspiration and vacuum-assistedbiopsy in the ultrasound-guided treatment of lactational breast abscesses. Methods: Between January 2005 and December 2014, a total of 74 patients presented withlactational breast abscesses. Thirty of these patients underwent treatment with antibioticsalone, while the remaining 44 lactating women with breast abscesses were treated withneedle aspiration (n=25 or vacuum-assisted biopsy (n=19. Age, duration of lactation, abscess diameter, pus culture results, the number of interventions, the healing time, and the cure rate were reviewed and compared between these two groups. The Student’s t test and the chi-square test were used to compare the variables. Results: No significant difference was found in the cure rate between the needle aspirationgroup (22/25, 88% and the vacuum-assisted biopsy group (18/19, 94.7% (P=0.441. However, the mean healing time was significantly shorter in the vacuum-assisted biopsy group (6.7 days than in the needle aspiration group (9.0 days (P=0.001. Conclusion: Vacuum-assisted biopsy is a viable option for the management of lactational breast abscesses and was found to lead to a shorter healing time than needle aspiration. However, further study is necessary to establish the clinical efficacy of vacuum-assisted biopsy in the management of lactational breast abscesses.

  9. A Single-Institution Experience in Percutaneous Image-Guided Biopsy of Malignant Pleural Mesothelioma

    International Nuclear Information System (INIS)

    Welch, B. T.; Eiken, P. W.; Atwell, T. D.; Peikert, T.; Yi, E. S.; Nichols, F.; Schmit, G. D.

    2017-01-01

    PurposeMesothelioma has been considered a difficult pathologic diagnosis to achieve via image-guided core needle biopsy. The purpose of this study was to assess the diagnostic sensitivity of percutaneous image-guided biopsy for diagnosis of pleural mesothelioma.Materials and MethodsRetrospective review was performed to identify patients with a confirmed diagnosis of pleural mesothelioma and who underwent image-guided needle biopsy between January 1, 2002, and January 1, 2016. Thirty-two patients with pleural mesothelioma were identified and included for analysis in 33 image-guided biopsy procedures. Patient, procedural, and pathologic characteristics were recorded. Complications were characterized via standardized nomenclature [Common Terminology for Clinically Adverse Events (CTCAE)].ResultsPercutaneous image-guided biopsy was associated with an overall sensitivity of 81%. No CTCAE clinically significant complications were observed. No image-guided procedures were complicated by pneumothorax or necessitated chest tube placement. No patients had tumor seeding of the biopsy tract.ConclusionPercutaneous image-guided biopsy can achieve high sensitivity for pathologic diagnosis of pleural mesothelioma with a low procedural complication rate, potentially obviating need for surgical biopsy.

  10. A Single-Institution Experience in Percutaneous Image-Guided Biopsy of Malignant Pleural Mesothelioma

    Energy Technology Data Exchange (ETDEWEB)

    Welch, B. T., E-mail: Welch.brian@mayo.edu; Eiken, P. W.; Atwell, T. D. [Mayo Clinic, Department of Radiology (United States); Peikert, T. [Mayo Clinic, Department of Pulmonary and Critical Care Medicine (United States); Yi, E. S. [Mayo Clinic, Department of Pathology (United States); Nichols, F. [Mayo Clinic, Department of Thoracic Surgery (United States); Schmit, G. D. [Mayo Clinic, Department of Radiology (United States)

    2017-06-15

    PurposeMesothelioma has been considered a difficult pathologic diagnosis to achieve via image-guided core needle biopsy. The purpose of this study was to assess the diagnostic sensitivity of percutaneous image-guided biopsy for diagnosis of pleural mesothelioma.Materials and MethodsRetrospective review was performed to identify patients with a confirmed diagnosis of pleural mesothelioma and who underwent image-guided needle biopsy between January 1, 2002, and January 1, 2016. Thirty-two patients with pleural mesothelioma were identified and included for analysis in 33 image-guided biopsy procedures. Patient, procedural, and pathologic characteristics were recorded. Complications were characterized via standardized nomenclature [Common Terminology for Clinically Adverse Events (CTCAE)].ResultsPercutaneous image-guided biopsy was associated with an overall sensitivity of 81%. No CTCAE clinically significant complications were observed. No image-guided procedures were complicated by pneumothorax or necessitated chest tube placement. No patients had tumor seeding of the biopsy tract.ConclusionPercutaneous image-guided biopsy can achieve high sensitivity for pathologic diagnosis of pleural mesothelioma with a low procedural complication rate, potentially obviating need for surgical biopsy.

  11. BioCore Guide: A Tool for Interpreting the Core Concepts of Vision and Change for Biology Majors

    Science.gov (United States)

    Freeman, Scott; Wenderoth, Mary Pat; Crowe, Alison J.

    2014-01-01

    Vision and Change in Undergraduate Biology Education outlined five core concepts intended to guide undergraduate biology education: 1) evolution; 2) structure and function; 3) information flow, exchange, and storage; 4) pathways and transformations of energy and matter; and 5) systems. We have taken these general recommendations and created a Vision and Change BioCore Guide—a set of general principles and specific statements that expand upon the core concepts, creating a framework that biology departments can use to align with the goals of Vision and Change. We used a grassroots approach to generate the BioCore Guide, beginning with faculty ideas as the basis for an iterative process that incorporated feedback from more than 240 biologists and biology educators at a diverse range of academic institutions throughout the United States. The final validation step in this process demonstrated strong national consensus, with more than 90% of respondents agreeing with the importance and scientific accuracy of the statements. It is our hope that the BioCore Guide will serve as an agent of change for biology departments as we move toward transforming undergraduate biology education. PMID:26086653

  12. Preoperative US-guided hook-needle insertion in recurrent lymph nodes of papillary thyroid cancer: A help for the surgeon

    International Nuclear Information System (INIS)

    Duprez, Raphaelle; Lebas, Patrick; Marc, Olivier Saint; Mongeois, Elise; Emy, Philippe; Michenet, Patrick

    2010-01-01

    Objective: The objective of this study is to investigate whether preoperative ultrasound guided insertion of a hook-needle is useful in reoperations for cervical recurrent lymph node metastases of papillary thyroid cancer. Patients and methods: 8 patients with operated papillary thyroid cancer were included in this study. They all had suspicious nonpalpable cervical lymph nodes discovered during follow-up. These lymph nodes were identified by ultrasound imaging and their metastatic nature was confirmed by fine needle aspiration cytology and measurement of in situ thyroglobulin. In all cases, surgical excision of these lymph nodes was decided. All 8 patients had a hook-needle inserted in the suspicious lymph node(s) preoperatively and under ultrasound guidance. Results and conclusion: In all 8 patients, the suspicious lymph nodes were removed and their metastatic nature was confirmed by the final pathological examination. This localization technique is very helpful for the surgeon during the excision of small and nonpalpable lymph nodes, especially in previously operated area.

  13. Image-guided breast biopsy: state-of-the-art

    Energy Technology Data Exchange (ETDEWEB)

    O' Flynn, E.A.M., E-mail: lizoflynn@doctors.org.u [South East London Breast Screening Programme and National Breast Screening Training Centre, Kings College Hospital NHS Foundation Trust, London SE5 9RS (United Kingdom); Wilson, A.R.M.; Michell, M.J. [South East London Breast Screening Programme and National Breast Screening Training Centre, Kings College Hospital NHS Foundation Trust, London SE5 9RS (United Kingdom)

    2010-04-15

    Percutaneous image-guided breast biopsy is widely practised to evaluate predominantly non-palpable breast lesions. There has been steady development in percutaneous biopsy techniques. Fine-needle aspiration cytology was the original method of sampling, followed in the early 1990s by large core needle biopsy. The accuracy of both has been improved by ultrasound and stereotactic guidance. Larger bore vacuum-assisted biopsy devices became available in the late 1990s and are now commonplace in most breast units. We review the different types of breast biopsy devices currently available together with various localization techniques used, focusing on their advantages, limitations and current controversial clinical management issues.

  14. Comparison of needle aspiration and vacuum-assisted biopsy in the ultrasound-guided drainage of lactational breast abscesses

    OpenAIRE

    Kang, Yun-Dan; Kim, You Me

    2015-01-01

    Purpose: The purpose of this study was to compare needle aspiration and vacuum-assistedbiopsy in the ultrasound-guided treatment of lactational breast abscesses. Methods: Between January 2005 and December 2014, a total of 74 patients presented withlactational breast abscesses. Thirty of these patients underwent treatment with antibioticsalone, while the remaining 44 lactating women with breast abscesses were treated withneedle aspiration (n=25) or vacuum-assisted biopsy (n=19). Age, duration ...

  15. Oblique needle segmentation and tracking for 3D TRUS guided prostate brachytherapy

    International Nuclear Information System (INIS)

    Wei Zhouping; Gardi, Lori; Downey, Donal B.; Fenster, Aaron

    2005-01-01

    An algorithm was developed in order to segment and track brachytherapy needles inserted along oblique trajectories. Three-dimensional (3D) transrectal ultrasound (TRUS) images of the rigid rod simulating the needle inserted into the tissue-mimicking agar and chicken breast phantoms were obtained to test the accuracy of the algorithm under ideal conditions. Because the robot possesses high positioning and angulation accuracies, we used the robot as a ''gold standard,'' and compared the results of algorithm segmentation to the values measured by the robot. Our testing results showed that the accuracy of the needle segmentation algorithm depends on the needle insertion distance into the 3D TRUS image and the angulations with respect to the TRUS transducer, e.g., at a 10 deg. insertion anglulation in agar phantoms, the error of the algorithm in determining the needle tip position was less than 1 mm when the insertion distance was greater than 15 mm. Near real-time needle tracking was achieved by scanning a small volume containing the needle. Our tests also showed that, the segmentation time was less than 60 ms, and the scanning time was less than 1.2 s, when the insertion distance into the 3D TRUS image was less than 55 mm. In our needle tracking tests in chicken breast phantoms, the errors in determining the needle orientation were less than 2 deg. in robot yaw and 0.7 deg. in robot pitch orientations, for up to 20 deg. needle insertion angles with the TRUS transducer in the horizontal plane when the needle insertion distance was greater than 15 mm

  16. Ultrasound-guided Interventions for Core and Hip Injuries in Athletes.

    Science.gov (United States)

    McCarthy, Eoghan; Hegazi, Tarek M; Zoga, Adam C; Morrison, William B; Meyers, William C; Poor, Alex E; Nevalainen, Mika T; Roedl, Johannes B

    2016-09-01

    Trauma and the mechanical strain of high-energy activity predispose athletes to pelvic injuries. Magnetic resonance imaging remains the primary modality for diagnosing these conditions, but ultrasonography-guided interventions are important in the management of core muscle, hip, and other pelvic conditions. This article reviews ultrasonography-guided interventions for injuries at the core, including the pelvis and hips. It reviews common injuries, procedure optimization, medication preparation, clinical evidence behind injections, tenotomy, and platelet-rich plasma. These interventions are especially important in athletes, because ultrasonography-guided procedures are often undertaken early in the treatment process, paralleling conservative rehabilitation to facilitate a faster return to play. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Ultrasound-guided percutaneous needle electrolysis in chronic lateral epicondylitis: short-term and long-term results

    Science.gov (United States)

    Valera-Garrido, Fermín; Minaya-Muñoz, Francisco; Medina-Mirapeix, Francesc

    2014-01-01

    Background Ultrasound (US)-guided percutaneous needle electrolysis (PNE) is a novel minimally invasive approach which consists of the application of a galvanic current through an acupuncture needle. Objective To evaluate the clinical and ultrasonographic effectiveness of a multimodal programme (PNE, eccentric exercise (EccEx) and stretching) in the short term for patients with chronic lateral epicondylitis, and to determine whether the clinical outcomes achieved decline over time. Methods A one-way repeated measures study was performed in a clinical setting in 36 patients presenting with lateral epicondylitis. The patients received one session of US-guided PNE per week over 4–6 weeks, associated with a home programme of EccEx and stretching. The main outcome measures were severity of pain, disability (Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire), structural tendon changes (US), hypervascularity and patients’ perceptions of overall outcome. Measurements at 6, 26 and 52 weeks follow-up included recurrence rates (increase in severity of pain or disability compared with discharge), perception of overall outcome and success rates. Results All outcome measures registered significant improvements between pre-intervention and discharge. Most patients (n=30, 83.3%) rated the overall outcome as ‘successful’ at 6 weeks. The ultrasonographic findings showed that the hypoechoic regions and hypervascularity of the extensor carpi radialis brevis changed significantly. At 26 and 52 weeks, all participants (n=32) perceived a ‘successful’ outcome. Recurrence rates were null after discharge and at follow-up at 6, 26 and 52 weeks. Conclusions Symptoms and degenerative structural changes of chronic lateral epicondylitis are reduced after US-guided PNE associated with EccEx and stretching, with encouragingly low recurrences in the mid to long term. Trial registration number ClinicalTrials.gov identifier: NCT02085928. PMID:25122629

  18. Novel Double-Needle System That Can Prevent Intravascular Injection of Any Filler

    Directory of Open Access Journals (Sweden)

    Hsiang Huang, MD

    2017-09-01

    Full Text Available Summary:. A new type of needle system combines 2 parts, an inner needle and an outer needle. The inner needle is used for filler injection and the outer needle acts as a guiding needle that can observe blood reflow when inserting into the vessel lumen during injection process. This new needle system can be used for all kinds of filler, providing real time monitoring for physician and preventing intravascular injection of any filler.

  19. Application of B-ultrasonic guided fine needle aspiration cytology in diagnosis of tuberculous lymphadenitis

    International Nuclear Information System (INIS)

    Yu Qi; Yang Jianghui; Li Ning

    2011-01-01

    To explore the value of B-ultrasonic guided fine needle aspiration cytology(FNAC) in the diagnosis of tuberculous lymphadenitis (TB). The patients were carried out FNAC under B-ultrasonic guidance to distinguish the tuberculosis lymphadenitis. With the FNAC diagnosis of lymphoglandulae and reactive hyperplasia lesions of 80 cases, 41 cases were confirmed by histopathology. With FNAC diagnosed tuberculosis 36 cases, granulomatous lymphadenitis 2 cases and reactive hyperplasia 3 cases. FANC is one of efficient method to diagnosis the tuberculous lymphadenitis. This method has some limitations, but it could be overcome by biopsy or polymerase chain reaction. (authors)

  20. En bloc excision of nonpalpable breast lesions using the advanced breast biopsy instrumentation system: an alternative to needle guided surgery?

    International Nuclear Information System (INIS)

    Lifrange, E.; Colin, C.; Dondelinger, R.F.; Fridman, V.

    2001-01-01

    This study was prospectively conducted to evaluate the clinical potential of the advanced breast biopsy instrumentation (ABBI) system as an alternative to needle localization and open surgery in the management of nonpalpable breast lesions (NPBL). One hundred and eighty-six consecutive patients were referred for management of NPBL. Thirty-six underwent an ABBI procedure, offered as a first step before possible surgery for lesions which would in any case have required complete excision. The 18 patients with a malignant ABBI biopsy underwent re-excision of the biopsy site and axillary dissection was carried out in cases of infiltrating carcinoma. The other 150 patients underwent image-guided needle biopsy. Following these procedures, 60/150 (40 %) patients underwent needle-guided surgery. Finally, 96/186 (51 %) patients required complete excision. A total of 43 benign lesions and 53 carcinomas were confirmed. Thirty-six out of 96 (38 %) excisions were obtained with the ABBI system; 17/43 (40 %) benign lesions and 11/53 (21 %) carcinomas were completely removed with the ABBI system. Out of 9 malignant specimens with a pathological size less than 10 mm, 5/9 (55 %) had tumor-free margins and in 8/9 (89 %) no residual disease was found at re-excision. The preliminary results of this study suggest that, in selected cases, en bloc excision using the ABBI procedure could be an alternative to conventional surgery. (orig.)

  1. Risks of Being Malignant or High Risk and Their Characteristics in Breast Lesions 20 mm or Larger After Benign Results on Ultrasonography-Guided 14-Gauge Core Needle Biopsy.

    Science.gov (United States)

    Moon, Hee Jung; Kim, Min Jung; Yoon, Jung Hyun; Kim, Eun-Kyung

    2016-06-01

    The malignancy risk, risk of being high-risk lesions after benign results on ultrasonography-guided 14-gauge core needle biopsies (US-CNBs), and their characteristics in breast lesions of 20 mm or greater were investigated. Eight hundred forty-seven breast lesions with benign results on US-CNB were classified as benign, high risk, and malignant through excision and clinical follow-up. The risks of being malignant or high risk were analyzed in all lesions, lesions 20 to 29 mm, and lesions 30 mm or greater. Their clinicopathological characteristics were evaluated. Of 847, 18 (2.1%) were malignant, 53 (6.3%) were high-risk lesions, and 776 (91.6%) were benign. Of 18 malignancies, 6 (33.3%) were malignant phyllodes tumors and 12 (66.7%) were carcinomas. In benign lesions 20 to 29 mm, risks of being malignant or high risk were 1.6% (9 of 566) and 4.4% (25 of 566). In 281 lesions 30 mm or greater, the risks of being malignant or high risk were 3.2% and 10%. The risk of being high risk in lesions 30 mm or greater was 10%, significantly higher than 4.4% of lesions 20 to 29 mm (P = 0.002). Excision can be considered in lesions measuring 20 mm or larger because of the 2.1% malignancy risk and the 6.3% risk of being high-risk lesions despite benign results on US-CNB. Excision should be considered in lesions measuring 30 mm or larger because of the 3.2% malignancy risk and the 10% risk of being high-risk lesions.

  2. Endoscopic ultrasound-guided fine-needle aspiration cytology in the evaluation of suspected tuberculosis in patients with isolated mediastinal lymphadenopathy

    DEFF Research Database (Denmark)

    Puri, R.; Vilmann, P.; Sud, R.

    2010-01-01

    Patients with suspected tuberculosis without pulmonary lesions and with mediastinal lymphadenopathy often pose a diagnostic challenge. Endoscopic ultrasound (EUS)-guided fine-needle aspiration (FNA) cytology is an established modality to evaluate mediastinal and abdominal lesions. The aim...... of the present study was to evaluate the role of EUS-FNA in isolated mediastinal lymphadenopathy in patients suspected of having tuberculosis....

  3. Value of Artisanal Simulators to Teach Ultrasound-Guided Percutaneous Biopsy Using a Tru-Cut Needle for Veterinary and Medical Students

    Science.gov (United States)

    de Araújo Setin, Raíza; Fortes Cirimbelli, Carolina; Mazeto Ercolin, Anna Carolina; Pires, Sâmara Turbay; Disselli, Tamiris; Ferrarini Nunes Soares Hage, Maria Cristina

    2018-01-01

    The present study aimed to evaluate the applicability of artisanal simulators to teach veterinary and medical students the ultrasound-guided percutaneous biopsy using a tru-cut needle. The artisanal simulators consisted of bovine liver between two layers of commercially available grape gelatin. Students were paired, with one doing the biopsy and…

  4. BioCore Guide: A Tool for Interpreting the Core Concepts of Vision and Change for Biology Majors.

    Science.gov (United States)

    Brownell, Sara E; Freeman, Scott; Wenderoth, Mary Pat; Crowe, Alison J

    2014-01-01

    Vision and Change in Undergraduate Biology Education outlined five core concepts intended to guide undergraduate biology education: 1) evolution; 2) structure and function; 3) information flow, exchange, and storage; 4) pathways and transformations of energy and matter; and 5) systems. We have taken these general recommendations and created a Vision and Change BioCore Guide-a set of general principles and specific statements that expand upon the core concepts, creating a framework that biology departments can use to align with the goals of Vision and Change. We used a grassroots approach to generate the BioCore Guide, beginning with faculty ideas as the basis for an iterative process that incorporated feedback from more than 240 biologists and biology educators at a diverse range of academic institutions throughout the United States. The final validation step in this process demonstrated strong national consensus, with more than 90% of respondents agreeing with the importance and scientific accuracy of the statements. It is our hope that the BioCore Guide will serve as an agent of change for biology departments as we move toward transforming undergraduate biology education. © 2014 S. E. Brownell et al. CBE—Life Sciences Education © 2014 The American Society for Cell Biology. This article is distributed by The American Society for Cell Biology under license from the author(s). It is available to the public under an Attribution–Noncommercial–Share Alike 3.0 Unported Creative Commons License (http://creativecommons.org/licenses/by-nc-sa/3.0).

  5. Transrectal ultrasound: Diagnosis of prostate cancer by a new biplane US-guided biopsy technique. Comparison of thin-needle cytology and histology with large-core biopsy

    International Nuclear Information System (INIS)

    Lee, F.; Littrup, P.; McLeary, R.; Kumasaka, G.; Borlaza, G.; McHugh, T.; Soiderer, M.; Roi, L.

    1986-01-01

    A new transperineal biopsy technique was developed that uses biplane transrectal US guidance for needle placement into anechoic-hypoechoic lesions thought to indicate prostate cancer (n = 83). The results of histologic studies on biopsy material obtained with a 22-gauge needle and of aspiration histologic studies on biopsy material obtained with a 19-gauge needle were compared with results of histologic studies on material obtained with a 14-gauge needle. When sufficient tissue was obtained, the positive biopsy yield was 61% by cytology and 58% by histology; the combined yield was 61%. A limited study ( n = 21) of histologic findings in biopsy material obtained with 19-gauge and 14-gauge needles showed equivalent diagnostic results. Sixty-seven percent of the biopsies were of lesions less than 1.5 cm in diameter, and 57% (13 of 23) of the biopsy-proved cancers in this group were either nonpalpable or only mildly suspicious on digital rectal examination

  6. Microarray analysis in clinical oncology: pre-clinical optimization using needle core biopsies from xenograft tumors

    International Nuclear Information System (INIS)

    Goley, Elizabeth M; Anderson, Soni J; Ménard, Cynthia; Chuang, Eric; Lü, Xing; Tofilon, Philip J; Camphausen, Kevin

    2004-01-01

    DNA microarray profiling performed on clinical tissue specimens can potentially provide significant information regarding human cancer biology. Biopsy cores, the typical source of human tumor tissue, however, generally provide very small amounts of RNA (0.3–15 μg). RNA amplification is a common method used to increase the amount of material available for hybridization experiments. Using human xenograft tissue, we sought to address the following three questions: 1) is amplified RNA representative of the original RNA profile? 2) what is the minimum amount of total RNA required to perform a representative amplification? 3) are the direct and indirect methods of labeling the hybridization probe equivalent? Total RNA was extracted from human xenograft tissue and amplified using a linear amplification process. RNA was labeled and hybridized, and the resulting images yielded data that was extracted into two categories using the mAdb system: 'all genes' and 'outliers'. Scatter plots were generated for each slide and Pearson Coefficients of correlation were obtained. Results show that the amplification of 5 μg of total RNA yields a Pearson Correlation Coefficient of 0.752 (N = 6,987 genes) between the amplified and total RNA samples. We subsequently determined that amplification of 0.5 μg of total RNA generated a similar Pearson Correlation Coefficient as compared to the corresponding original RNA sample. Similarly, sixty-nine percent of total RNA outliers were detected with 5 μg of amplified starting RNA, and 55% of outliers were detected with 0.5 μg of starting RNA. However, amplification of 0.05 μg of starting RNA resulted in a loss of fidelity (Pearson Coefficient 0.669 between amplified and original samples, 44% outlier concordance). In these studies the direct or indirect methods of probe labeling yielded similar results. Finally, we examined whether RNA obtained from needle core biopsies of human tumor xenografts, amplified and indirectly

  7. A new robotic needle insertion method to minimise attendant prostate motion

    International Nuclear Information System (INIS)

    Lagerburg, Vera; Moerland, Marinus A.; Vulpen, Marco van; Lagendijk, Jan J.W.

    2006-01-01

    Background and purpose: The purpose of this study is to investigate the efficacy of a new needle insertion method (tapping instead of pushing) in reducing attendant tissue motion. This can be useful in applications where tissue motion due to needle insertion is problematic such as e.g. MRI-guided prostate brachytherapy and breast biopsies. In this study we will focus on prostate motion due to needle insertion. Material and methods: Prostate motion due to needle insertion was measured in 30 patients, who were transperineally implanted with fiducial gold markers for position verification in prostate intensity modulated radiotherapy. In total 32 needles were manually pushed into the prostate and 29 were tapped with a prototype robotic system. The prostate motion in the cranio-caudal direction was measured on the video record of the ultrasound images. Differences in prostate motion between the two needle insertion methods were analysed making use of SPSS. Results: The mean prostate motion was 5.6 mm (range 0.3-21.6) when the needle was pushed and 0.9 mm (range 0-2.0) when the needle was tapped into the prostate (p < 0.001). Conclusion: Prostate motion was significantly less when the needle was tapped into the prostate compared to when the needle was pushed. This result is important for the development of a tapping, MRI-guided, prostate implant robotic system

  8. Ultrasound-guided fine-needle aspiration biopsy of the thyroid.

    Science.gov (United States)

    Tambouret, R; Szyfelbein, W M; Pitman, M B

    1999-10-25

    We reviewed the Massachusetts General Hospital experience with ultrasound-guided fine-needle aspiration biopsies (FNABs) of the thyroid to determine the indications, rate of unsatisfactory smears, correlation with excisional biopsy results, and verification of efficient use of personnel time. All radiologically guided FNABs of the thyroid from January 1993 through June 1997 were reviewed. As a measure of efficient use of technologist time, a sample of times spent by the technologist during the procedure for 20 cases in 1993 and 1997 was compared with that of an equal number of random nonthyroid image guided FNABs. Two hundred-ninety FNABs were identified in 251 patients, representing 12% of all thyroid FNABs and 11% of all radiologically guided FNABs. Indications in the 251 patients included multiple nodules (78), solitary nodules (61), complex nodules (39), prior failed FNAB (39), thyroid bed abnormalities post-thyroidectomy (21), difficult access (7), and investigation of recurrent tumor in residual thyroid lobe (6). Available records indicated 118 lesions were palpable and 45 were nonpalpable; the physical examination characteristics of the remainder (88) were not stated. Diagnoses included 44 unsatisfactory cases (15%), 103 macrofollicular lesions, 20 microfollicular lesions, 26 mixed macro/microfollicular lesions, 5 oxyphilic lesions, 1 trabecular pattern, 15 nonspecific follicular cell pattern, 9 follicular cell atypia, 30 cysts, 11 thyroiditis, 23 malignant tumors, and 3 other (1 parathyroid, 2 lymph node). Eighty-nine FNABs from 76 patients had subsequent surgical biopsy. Excisional biopsies in 14 unsatisfactory FNABs were benign. In the remaining 75 FNABs from 67 patients, 18 malignancies on FNAB were correctly diagnosed, but 3 other papillary carcinomas were only qualified as atypical follicular cells on cytology. No false-positive cases occurred. Of 15 macrofollicular lesions on cytology, 10 were adenomas on excision, only 2 of which were microfollicular

  9. Radiation resistivity of pure silica core image guides for industrial fiberscopes

    International Nuclear Information System (INIS)

    Okamoto, Shinichi; Ohnishi, Tokuhiro; Kanazawa, Tamotsu; Tsuji, Yukio; Hayami, Hiroyuki; Ishitani, Tadayoshi; Akutsu, Takeji; Suzuki, Koichi.

    1991-01-01

    Industrial fiberscopes incorporating pure silica core image guides have been extensively used for remote visual inspection in radiation fields including nuclear power plants, owing to their superior radiation resistivity. The authors have been intensively conducting R and D on improving radiation resistivity of pure silica core image guides. This paper reports the results of experiments to compare the effects of core materials on radiation resistivity and to investigate the dependence of radiation resistivity on total dose, does rate, and support pipe material. The results confirmed the superior radiation resistivity of the core material containing fluorine at any irradiation condition and indicated the existence of a critical dose rate at which radiation-induced deterioration was stabilized. No difference in radiation resistivity attributable to support layer material was observed. (author)

  10. Fine-needle aspiration and core biopsy in the diagnosis of breast lesions: A comparison and review of the literature

    Directory of Open Access Journals (Sweden)

    Suvradeep Mitra

    2016-01-01

    Full Text Available In recent times, the diagnosis of breast lesions has mostly become dependent on core needle biopsies (CNBs with a gradual reduction in the rate of performing fine-needle aspiration cytology (FNAC. Both the procedures have their pros and cons and outsmart each other taking into account different parameters. Both the methods are found to be fraught with loopholes, taking into account different performance indices, diagnostic accuracy and concordance, patient benefit, and cost-effectiveness. Unlike the popular belief of an absolute superiority of CNB over FNAC, the literature review does not reveal a very distinct demarcation in many aspects. We recommend judicious use of these diagnostic modalities in resource-limited settings and screening programs taking into account parameters such as palpability and availability of an experienced cytopathologist.

  11. Ultrasound-Guided Fine-Needle Aspiration Biopsy of Thyroid Nodules: is it Necessary to Use Local Anesthesia for the Application of One Needle Puncture?

    International Nuclear Information System (INIS)

    Kim, Dong Wook; Rho, Myung Ho; Kim, Ki Nam

    2009-01-01

    This study was designed to evaluate the difference in the degree of patient pain for an ultrasound-guided fine-needle aspiration biopsy (USFNAB) of a thyroid nodule with one needle puncture with and without local anesthesia. A total of 50 patients participated in the study. We examined prospective patients who would undergo US-FNABs of two thyroid nodules (larger than 10 mm maximum diameter), which were located in separate thyroid lobes. For one of these thyroid nodules, US-FNAB was performed following the administration of local anesthesia; for the other nodule, no anesthesia was administered. The application of anesthesia was alternatively administered between patients (either prior to the first US-FNAB procedure or prior to the second procedure). For all patients, the degree of pain during and after each US-guided FNAB was evaluated according to a 4-category verbal rating scale (VRS), an 11-point numeric rating scale (NRS) and a 100-mm visual analogue scale (VAS). The mean maximum diameters of thyroid nodules examined by US-FNAB with the use of local anesthesia and with no local anesthesia were 13.6 mm and 13.0 mm, respectively. There was no significant difference in nodule size (p > 0.05) between two groups. For the VRS, there were 27 patients with a higher pain score when local anesthesia was used and four patients with a higher pain score when no local anesthesia was administered. Nineteen patients had equivalent pain score for both treatments. This finding was statistically significant (p < 0.001). For the NRS, there were 33 patients with a higher pain score when local anesthesia was used and 10 patients with a higher pain score when no local anesthesia was administered. Seven patients had an equivalent pain score for each treatment. This finding was statistically significant (p < 0.001). For the VAS, there were 35 patients with a higher pain score when local anesthesia was used and 11 patients with a higher pain score where no local anesthesia was

  12. Application of a New Guiding System in Percutaneous Biopsies

    International Nuclear Information System (INIS)

    Petsas, Theodore; Tsota, Irene; Kalogeropoulou, Christina P.; Liatsikos, Evangelos N.

    2007-01-01

    We herein describe the application of a new guiding system designed for percutaneous biopsies. The guiding system set is composed of a 0.41 mm (27G) stainless steel guide stylet and a 22G Chiba needle. Following the initial insertion of the Chiba needle, the stylet is advanced via the needle toward the lesion. The stylet serves either as a guide for the Chiba needle or as an exchange wire for the introduction of larger or cutting biopsy needles. The stylet can also be curved prior to its insertion to facilitate access to lesions which require needle redirection. The technique was applied to 117 cases (54 thoracic, 31 abdominal, 21 pelvic, and 11 vertebral lesions.) The main advantage of the stylet is its small diameter, rendering it atraumatic and permitting multiple punctures for the successful final targeting of the lesion. With this guiding set we achieved targeting of difficult lesions. Furthermore, larger needles were more easily introduced in locations that posed technical difficulties. No major complications were observed. The complication rate was comparable to that of the conventional biopsy technique. The technique using the guide stylet was easily performed and could be applied to almost all organs

  13. Prevalence of fluoroquinolone-resistant rectal flora in patients undergoing transrectal ultrasound-guided prostate needle biopsy: A prospective multicenter study.

    Science.gov (United States)

    Chung, Ho Seok; Hwang, Eu Chang; Yu, Ho Song; Jung, Seung Il; Lee, Sun Ju; Lim, Dong Hoon; Cho, Won Jin; Choe, Hyun Sop; Lee, Seung-Ju; Park, Sung Woon

    2018-03-01

    To estimate the prevalence of fluoroquinolone-resistant rectal flora in patients undergoing transrectal ultrasound-guided prostate needle biopsy and to identify the high-risk groups. From January 2015 to March 2016, rectal swabs of 557 men who underwent transrectal ultrasound-guided prostate needle biopsy were obtained from five institutions. Clinical variables, including demographics, rectal swab culture results and infectious complications, were evaluated. Univariable and multivariable analyses were used to identify the risk factors for fluoroquinolone resistance of rectal flora and infectious complications. The incidence of fluoroquinolone-resistant and extended-spectrum beta-lactamase production was 48.1 and 11.8%, respectively. The most common fluoroquinolone-resistant bacteria was Escherichia coli (81% of total fluoroquinolone-resistant bacteria, 39% of total rectal flora), and 16 (2.9%) patients had infectious complications. Univariable and multivariable analysis of clinical parameters affecting fluoroquinolone resistance showed no factor associated with fluoroquinolone resistance of rectal flora. The clinical parameter related to infectious complications after prostate biopsy was a history of operation within 6 months (relative risk 6.60; 95% confidence interval 1.99-21.8, P = 0.002). These findings suggest that a risk-based approach by history taking cannot predict antibiotic resistance of rectal flora, and physicians should consider targeted antibiotic prophylaxis or extended antibiotic prophylaxis for Korean patients undergoing transrectal ultrasound-guided prostate biopsy because of high antibiotic resistance of rectal flora. © 2017 The Japanese Urological Association.

  14. Stereotactic core needle breast biopsy marker migration: An analysis of factors contributing to immediate marker migration.

    Science.gov (United States)

    Jain, Ashali; Khalid, Maria; Qureshi, Muhammad M; Georgian-Smith, Dianne; Kaplan, Jonah A; Buch, Karen; Grinstaff, Mark W; Hirsch, Ariel E; Hines, Neely L; Anderson, Stephan W; Gallagher, Katherine M; Bates, David D B; Bloch, B Nicolas

    2017-11-01

    To evaluate breast biopsy marker migration in stereotactic core needle biopsy procedures and identify contributing factors. This retrospective study analyzed 268 stereotactic biopsy markers placed in 263 consecutive patients undergoing stereotactic biopsies using 9G vacuum-assisted devices from August 2010-July 2013. Mammograms were reviewed and factors contributing to marker migration were evaluated. Basic descriptive statistics were calculated and comparisons were performed based on radiographically-confirmed marker migration. Of the 268 placed stereotactic biopsy markers, 35 (13.1%) migrated ≥1 cm from their biopsy cavity. Range: 1-6 cm; mean (± SD): 2.35 ± 1.22 cm. Of the 35 migrated biopsy markers, 9 (25.7%) migrated ≥3.5 cm. Patient age, biopsy pathology, number of cores, and left versus right breast were not associated with migration status (P> 0.10). Global fatty breast density (P= 0.025) and biopsy in the inner region of breast (P = 0.031) were associated with marker migration. Superior biopsy approach (P= 0.025), locally heterogeneous breast density, and t-shaped biopsy markers (P= 0.035) were significant for no marker migration. Multiple factors were found to influence marker migration. An overall migration rate of 13% supports endeavors of research groups actively developing new biopsy marker designs for improved resistance to migration. • Breast biopsy marker migration is documented in 13% of 268 procedures. • Marker migration is affected by physical, biological, and pathological factors. • Breast density, marker shape, needle approach etc. affect migration. • Study demonstrates marker migration prevalence; marker design improvements are needed.

  15. Percutaneous CT-guided biopsy for lung lesions 1 cm or smaller: the technique, results and complication

    International Nuclear Information System (INIS)

    Song, Chi Sung

    2006-01-01

    The author wanted to assess the diagnostic accuracy and safety of percutaneous biopsy for lung lesions 1 cm or smaller; the biopsies were performed on the basis of the modified coaxial technique under CT guidance. Thirty-five patients (22 men and 13 women) 23-76 years old (average age: 56.8 years) with lung lesions 1 cm or smaller underwent CT-guided percutaneous biopsy. Fifteen patients had underlying primary malignancies. After an 18 G guiding cannula was introduced to the border of the small lung lesion via the modified coaxial technique, fine-needle aspiration biopsy with 21 G needle and core tissue biopsies with 19.5 G or 20 G biopsy guns were performed through the lumen of the guiding cannula. The core tissue biopsies were finished after 6 macroscopic core tissue specimens were obtained. When the needle hit the eccentric portion of the small lung lesion, a 'fanning-out' technique with using the guiding cannula was applied to get multiple core tissue specimens from the small lung lesion. The diagnostic accuracy of this method was evaluated and the complications were reviewed. Both the cytopathologic and histopathologic specimens were obtained in all 35 cases. The fanning-out technique was necessary in 15 cases (43%) for obtaining six core tissue specimens from small lesions. The final diagnoses were 17 malignant lesions and 18 benign lesions. Sixteen lesions were true-positive, eighteen were true-negative, none was false-positive and one was false-negative. The overall diagnostic accuracy was 97%. The sensitivity for detecting malignancy and the specificity for benign lesion were 94% and 100%, respectively. The positive and negative predictive values were 100% and 95%, respectively. The diagnostic ability to characterize the specific cell type of the malignant lesion was 94% (16 of 17), that for the benign lesions was 83% (15 of 18), and overall diagnostic ability was 89% (31 of 35). Five patients (14%) developed a pneumopthorax, and one of them (3%) received

  16. Endobronchial ultrasound-guided transbronchial needle aspiration for lung cancer staging: early experience in Brazil*,**

    Science.gov (United States)

    Figueiredo, Viviane Rossi; Cardoso, Paulo Francisco Guerreiro; Jacomelli, Márcia; Demarzo, Sérgio Eduardo; Palomino, Addy Lidvina Mejia; Rodrigues, Ascédio José; Terra, Ricardo Mingarini; Pego-Fernandes, Paulo Manoel; Carvalho, Carlos Roberto Ribeiro

    2015-01-01

    Objective: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive, safe and accurate method for collecting samples from mediastinal and hilar lymph nodes. This study focused on the initial results obtained with EBUS-TBNA for lung cancer and lymph node staging at three teaching hospitals in Brazil. Methods: This was a retrospective analysis of patients diagnosed with lung cancer and submitted to EBUS-TBNA for mediastinal lymph node staging. The EBUS-TBNA procedures, which involved the use of an EBUS scope, an ultrasound processor, and a compatible, disposable 22 G needle, were performed while the patients were under general anesthesia. Results: Between January of 2011 and January of 2014, 149 patients underwent EBUS-TBNA for lymph node staging. The mean age was 66 ± 12 years, and 58% were male. A total of 407 lymph nodes were sampled by EBUS-TBNA. The most common types of lung neoplasm were adenocarcinoma (in 67%) and squamous cell carcinoma (in 24%). For lung cancer staging, EBUS-TBNA was found to have a sensitivity of 96%, a specificity of 100%, and a negative predictive value of 85%. Conclusions: We found EBUS-TBNA to be a safe and accurate method for lymph node staging in lung cancer patients. PMID:25750671

  17. Endobronchial ultrasound-guided transbronchial needle aspiration for lung cancer staging: early experience in Brazil,

    Directory of Open Access Journals (Sweden)

    Viviane Rossi Figueiredo

    2015-02-01

    Full Text Available Objective: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA is a minimally invasive, safe and accurate method for collecting samples from mediastinal and hilar lymph nodes. This study focused on the initial results obtained with EBUS-TBNA for lung cancer and lymph node staging at three teaching hospitals in Brazil. Methods: This was a retrospective analysis of patients diagnosed with lung cancer and submitted to EBUS-TBNA for mediastinal lymph node staging. The EBUS-TBNA procedures, which involved the use of an EBUS scope, an ultrasound processor, and a compatible, disposable 22 G needle, were performed while the patients were under general anesthesia. Results: Between January of 2011 and January of 2014, 149 patients underwent EBUS-TBNA for lymph node staging. The mean age was 66 ± 12 years, and 58% were male. A total of 407 lymph nodes were sampled by EBUS-TBNA. The most common types of lung neoplasm were adenocarcinoma (in 67% and squamous cell carcinoma (in 24%. For lung cancer staging, EBUS-TBNA was found to have a sensitivity of 96%, a specificity of 100%, and a negative predictive value of 85%. Conclusions: We found EBUS-TBNA to be a safe and accurate method for lymph node staging in lung cancer patients.

  18. Endobronchial ultrasound-guided transbronchial needle aspiration for lung cancer staging: early experience in Brazil.

    Science.gov (United States)

    Figueiredo, Viviane Rossi; Cardoso, Paulo Francisco Guerreiro; Jacomelli, Márcia; Demarzo, Sérgio Eduardo; Palomino, Addy Lidvina Mejia; Rodrigues, Ascédio José; Terra, Ricardo Mingarini; Pego-Fernandes, Paulo Manoel; Carvalho, Carlos Roberto Ribeiro

    2015-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive, safe and accurate method for collecting samples from mediastinal and hilar lymph nodes. This study focused on the initial results obtained with EBUS-TBNA for lung cancer and lymph node staging at three teaching hospitals in Brazil. This was a retrospective analysis of patients diagnosed with lung cancer and submitted to EBUS-TBNA for mediastinal lymph node staging. The EBUS-TBNA procedures, which involved the use of an EBUS scope, an ultrasound processor, and a compatible, disposable 22 G needle, were performed while the patients were under general anesthesia. Between January of 2011 and January of 2014, 149 patients underwent EBUS-TBNA for lymph node staging. The mean age was 66 ± 12 years, and 58% were male. A total of 407 lymph nodes were sampled by EBUS-TBNA. The most common types of lung neoplasm were adenocarcinoma (in 67%) and squamous cell carcinoma (in 24%). For lung cancer staging, EBUS-TBNA was found to have a sensitivity of 96%, a specificity of 100%, and a negative predictive value of 85%. We found EBUS-TBNA to be a safe and accurate method for lymph node staging in lung cancer patients.

  19. Yield and Safety Profile of Ultrasound Guided Fine Needle Aspiration Cytology (FNAC) of Lymph Nodes

    International Nuclear Information System (INIS)

    Sattar, A.; Wahab, S.; Javed, A.; Shamim, S. H.

    2016-01-01

    Objective: To determine the re-biopsy rate, positive yield and safety profile of ultrasound guided fine needle aspiration cytology (FNAC) in cervical lymph nodes in terms of its complications and repeat procedures. Study Design: An analytical study. Place and Duration of Study: Department of Vascular and Interventional Radiology, Dow University Hospital, Dow University of Health Sciences, Karachi, from June to December 2013. Methodology: Eighty neck swellings, which were found to be lymph nodes on ultrasound, underwent ultrasound guided FNAC, from outpatients. Lymph nodes which were included in the study were those that were not easily palpable, located near major blood vessels, where patient refused of direct palpation and wanted image guided FNAC, those directly sent by physician for image guided FNAC and where blind biopsy remained inconclusive. Patients who refused on explanation or did not give consent were excluded. Complications and repeat biopsy were noted. Result: This study consisted of 80 cases, of which 51 cases (63.75 percentage) were female and 29 cases (36.25 percentage) were male. Repeat biopsy was required in 1 case (1.6 percentage). There were no procedure-related complications. A total of 44 cases (55 percentage) revealed evidence suggesting or confirming the existence of tuberculosis. Rest of the others showed other benign lesions, reactive lymphadenopathy and malignancy. Conclusion: Ultrasound guided FNAC is a safe procedure with low re-biopsy rate that aids diagnosis. The predominant cause of cervical lymphadenopathy in this study was tuberculous lymphadenitis. (author)

  20. Size and Ultrasound Features Affecting Results of Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules.

    Science.gov (United States)

    Dong, YiJie; Mao, MinJing; Zhan, WeiWei; Zhou, JianQiao; Zhou, Wei; Yao, JieJie; Hu, YunYun; Wang, Yan; Ye, TingJun

    2017-11-09

    Our goal was to assess the diagnostic efficacy of ultrasound (US)-guided fine-needle aspiration (FNA) of thyroid nodules according to size and US features. A retrospective correlation was made with 1745 whole thyroidectomy and hemithyroidectomy specimens with preoperative US-guided FNA results. All cases were divided into 5 groups according to nodule size (≤5, 5.1-10, 10.1-15, 15.1-20, and >20 mm). For target nodules, static images and cine clips of conventional US and color Doppler were obtained. Ultrasound images were reviewed and evaluated by two radiologists with at least 5 years US working experience without knowing the results of pathology, and then agreement was achieved. The Bethesda category I rate was higher in nodules larger than 15 mm (P 20 mm) with several US features tended to yield false-negative FNA results. © 2017 by the American Institute of Ultrasound in Medicine.

  1. Mediastinal abscess after endobronchial ultrasound-guided transbronchial needle aspiration: a case report and literature review.

    Science.gov (United States)

    Leong, Steven C; Marshall, Henry M; Bint, Michael; Yang, Ian A; Bowman, Rayleen V; Fong, Kwun M

    2013-10-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive technique that allows lung cancer nodal staging and biopsy of parabronchial and paratracheal tissue. Its simplicity, high diagnostic yield, ability to diagnose both benign and malignant conditions, and exceedingly low complication rate has resulted in rapid widespread adoption by surgeons and physicians. EBUS-TBNA-related complications, however, do occur and need to be considered when assessing the risk-benefit profile of performing the procedure, and if the patient represents with unexpected symptoms after the procedure. We describe a 64-year-old woman who presented with a mediastinal abscess 5 days after EBUS-TBNA. This case demonstrates the importance of considering EBUS-TBNA-related complications to guide relevant imaging decisions and antibiotic choices. We review the published literature regarding infective complications of EBUS-TBNA and propose possible pathophysiologies. These complications are likely to increase in frequency as the technique is more widely adopted.

  2. Magnetic resonance imaging-targeted, 3D transrectal ultrasound-guided fusion biopsy for prostate cancer: Quantifying the impact of needle delivery error on diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Peter R., E-mail: pmarti46@uwo.ca [Department of Medical Biophysics, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Cool, Derek W. [Department of Medical Imaging, The University of Western Ontario, London, Ontario N6A 3K7, Canada and Robarts Research Institute, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Romagnoli, Cesare [Department of Medical Imaging, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Fenster, Aaron [Department of Medical Biophysics, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Department of Medical Imaging, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Robarts Research Institute, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Ward, Aaron D. [Department of Medical Biophysics, The University of Western Ontario, London, Ontario N6A 3K7 (Canada); Department of Oncology, The University of Western Ontario, London, Ontario N6A 3K7 (Canada)

    2014-07-15

    Purpose: Magnetic resonance imaging (MRI)-targeted, 3D transrectal ultrasound (TRUS)-guided “fusion” prostate biopsy intends to reduce the ∼23% false negative rate of clinical two-dimensional TRUS-guided sextant biopsy. Although it has been reported to double the positive yield, MRI-targeted biopsies continue to yield false negatives. Therefore, the authors propose to investigate how biopsy system needle delivery error affects the probability of sampling each tumor, by accounting for uncertainties due to guidance system error, image registration error, and irregular tumor shapes. Methods: T2-weighted, dynamic contrast-enhanced T1-weighted, and diffusion-weighted prostate MRI and 3D TRUS images were obtained from 49 patients. A radiologist and radiology resident contoured 81 suspicious regions, yielding 3D tumor surfaces that were registered to the 3D TRUS images using an iterative closest point prostate surface-based method to yield 3D binary images of the suspicious regions in the TRUS context. The probabilityP of obtaining a sample of tumor tissue in one biopsy core was calculated by integrating a 3D Gaussian distribution over each suspicious region domain. Next, the authors performed an exhaustive search to determine the maximum root mean squared error (RMSE, in mm) of a biopsy system that gives P ≥ 95% for each tumor sample, and then repeated this procedure for equal-volume spheres corresponding to each tumor sample. Finally, the authors investigated the effect of probe-axis-direction error on measured tumor burden by studying the relationship between the error and estimated percentage of core involvement. Results: Given a 3.5 mm RMSE for contemporary fusion biopsy systems,P ≥ 95% for 21 out of 81 tumors. The authors determined that for a biopsy system with 3.5 mm RMSE, one cannot expect to sample tumors of approximately 1 cm{sup 3} or smaller with 95% probability with only one biopsy core. The predicted maximum RMSE giving P ≥ 95% for each

  3. Magnetic resonance imaging-targeted, 3D transrectal ultrasound-guided fusion biopsy for prostate cancer: Quantifying the impact of needle delivery error on diagnosis.

    Science.gov (United States)

    Martin, Peter R; Cool, Derek W; Romagnoli, Cesare; Fenster, Aaron; Ward, Aaron D

    2014-07-01

    Magnetic resonance imaging (MRI)-targeted, 3D transrectal ultrasound (TRUS)-guided "fusion" prostate biopsy intends to reduce the ∼23% false negative rate of clinical two-dimensional TRUS-guided sextant biopsy. Although it has been reported to double the positive yield, MRI-targeted biopsies continue to yield false negatives. Therefore, the authors propose to investigate how biopsy system needle delivery error affects the probability of sampling each tumor, by accounting for uncertainties due to guidance system error, image registration error, and irregular tumor shapes. T2-weighted, dynamic contrast-enhanced T1-weighted, and diffusion-weighted prostate MRI and 3D TRUS images were obtained from 49 patients. A radiologist and radiology resident contoured 81 suspicious regions, yielding 3D tumor surfaces that were registered to the 3D TRUS images using an iterative closest point prostate surface-based method to yield 3D binary images of the suspicious regions in the TRUS context. The probabilityP of obtaining a sample of tumor tissue in one biopsy core was calculated by integrating a 3D Gaussian distribution over each suspicious region domain. Next, the authors performed an exhaustive search to determine the maximum root mean squared error (RMSE, in mm) of a biopsy system that gives P ≥ 95% for each tumor sample, and then repeated this procedure for equal-volume spheres corresponding to each tumor sample. Finally, the authors investigated the effect of probe-axis-direction error on measured tumor burden by studying the relationship between the error and estimated percentage of core involvement. Given a 3.5 mm RMSE for contemporary fusion biopsy systems,P ≥ 95% for 21 out of 81 tumors. The authors determined that for a biopsy system with 3.5 mm RMSE, one cannot expect to sample tumors of approximately 1 cm(3) or smaller with 95% probability with only one biopsy core. The predicted maximum RMSE giving P ≥ 95% for each tumor was consistently greater when using

  4. Magnetic resonance imaging-targeted, 3D transrectal ultrasound-guided fusion biopsy for prostate cancer: Quantifying the impact of needle delivery error on diagnosis

    International Nuclear Information System (INIS)

    Martin, Peter R.; Cool, Derek W.; Romagnoli, Cesare; Fenster, Aaron; Ward, Aaron D.

    2014-01-01

    Purpose: Magnetic resonance imaging (MRI)-targeted, 3D transrectal ultrasound (TRUS)-guided “fusion” prostate biopsy intends to reduce the ∼23% false negative rate of clinical two-dimensional TRUS-guided sextant biopsy. Although it has been reported to double the positive yield, MRI-targeted biopsies continue to yield false negatives. Therefore, the authors propose to investigate how biopsy system needle delivery error affects the probability of sampling each tumor, by accounting for uncertainties due to guidance system error, image registration error, and irregular tumor shapes. Methods: T2-weighted, dynamic contrast-enhanced T1-weighted, and diffusion-weighted prostate MRI and 3D TRUS images were obtained from 49 patients. A radiologist and radiology resident contoured 81 suspicious regions, yielding 3D tumor surfaces that were registered to the 3D TRUS images using an iterative closest point prostate surface-based method to yield 3D binary images of the suspicious regions in the TRUS context. The probabilityP of obtaining a sample of tumor tissue in one biopsy core was calculated by integrating a 3D Gaussian distribution over each suspicious region domain. Next, the authors performed an exhaustive search to determine the maximum root mean squared error (RMSE, in mm) of a biopsy system that gives P ≥ 95% for each tumor sample, and then repeated this procedure for equal-volume spheres corresponding to each tumor sample. Finally, the authors investigated the effect of probe-axis-direction error on measured tumor burden by studying the relationship between the error and estimated percentage of core involvement. Results: Given a 3.5 mm RMSE for contemporary fusion biopsy systems,P ≥ 95% for 21 out of 81 tumors. The authors determined that for a biopsy system with 3.5 mm RMSE, one cannot expect to sample tumors of approximately 1 cm 3 or smaller with 95% probability with only one biopsy core. The predicted maximum RMSE giving P ≥ 95% for each tumor was

  5. Retrospective analysis of technical success rate and procedure-related complications of 867 percutaneous CT-guided needle biopsies of lung lesions.

    Science.gov (United States)

    Mills, M; Choi, J; El-Haddad, G; Sweeney, J; Biebel, B; Robinson, L; Antonia, S; Kumar, A; Kis, B

    2017-12-01

    To investigate the technical success rate and procedure-related complications of computed tomography (CT)-guided needle biopsy of lung lesions and to identify the factors that are correlated with the occurrence of procedure-related complications. This was a single- institution retrospective study of 867 consecutive CT-guided needle biopsies of lung lesions performed on 772 patients in a tertiary cancer centre. The technical success rate and complications were correlated with patient, lung lesion, and procedure-related variables. The technical success rate was 87.2% and the mortality rate was 0.12%. Of the 867 total biopsies 25.7% were associated with pneumothorax, and 6.5% required chest tube drainage. The haemothorax rate was 1.8%. There was positive correlation between the development of pneumothorax and smaller lesion diameter (ptechnical success and a low rate of major complications. The present study has revealed several variables that can be used to identify high-risk procedures. A post-procedural chest X-ray within hours after the procedure is highly recommended to identify high-risk patients who require chest tube placement. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  6. Accessible or Inaccessible? Diagnostic Efficacy of CT-Guided Core Biopsies of Head and Neck Masses

    Energy Technology Data Exchange (ETDEWEB)

    Cunningham, Jane D., E-mail: janecunningham0708@gmail.com; McCusker, Mark W.; Power, Sarah; PearlyTi, Joanna; Thornton, John; Brennan, Paul; Lee, Michael J.; O’Hare, Alan; Looby, Seamus [Beaumont Hospital, Department of Radiology (Ireland)

    2015-04-15

    PurposeTissue sampling of lesions in the head and neck is challenging due to complex regional anatomy and sometimes necessitates open surgical biopsy. However, many patients are poor surgical candidates due to comorbidity. Thus, we evaluated the use of CT guidance for establishing histopathological diagnosis of head and neck masses.MethodsAll consecutive patients (n = 22) who underwent CT-guided core biopsy of head or neck masses between April 2009 and August 2012 were retrospectively reviewed using the departmental CT interventional procedures database. The indication for each biopsy performed was to establish or exclude a diagnosis of neoplasia in patients with suspicious head or neck lesions found on clinical examination or imaging studies. Patients received conscious sedation and 18 G, semiautomated core needle biopsies were performed by experienced neuroradiologists using 16-slice multidetector row CT imaging guidance (Somatom Definition Siemens Medical Solutions, Germany). Histopathology results of each biopsy were analysed.ResultsSixteen of 22 biopsies that were performed (73 %) yielded a pathological diagnosis. Anatomic locations biopsied included: masticator (n = 7), parapharyngeal (n = 3), parotid (n = 3), carotid (n = 3), perivertebral (n = 3), pharyngeal (n = 2), and retropharyngeal (n = 1) spaces. Six biopsies (27 %) were nondiagnostic due to inadequate tissue sampling, particularly small biopsy sample size and failure to biopsy the true sampling site due to extensive necrosis. No major complications were encountered.ConclusionsThe use of CT guidance to perform core biopsies of head and neck masses is an effective means of establishing histopathological diagnosis and reduces the need for diagnostic open surgical biopsy and general anaesthesia.

  7. Diagnostic Accuracy of MRI-guided Percutaneous Transthoracic Needle Biopsy of Solitary Pulmonary Nodules

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Shangang, E-mail: 1198685580@qq.com [University of Jinan-Shandong Academy of Medical Science, Department of Radiation Oncology, Shandong Cancer Hospital and Institute, School of Medicine and Life Sciences (China); Li, Chengli, E-mail: chenglilichina@yeah.net [Shandong University, Department of Interventional MRI, Shandong Medical Imaging Research Institute (China); Yu, Xuejuan, E-mail: yuxuejuan2011@126.com [University of Jinan-Shandong Academy of Medical Science, Department of Radiation Oncology, Shandong Cancer Hospital and Institute, School of Medicine and Life Sciences (China); Liu, Ming, E-mail: mingliuyxs@163.com [Shandong University, Department of Interventional MRI, Shandong Medical Imaging Research Institute (China); Fan, Tingyong, E-mail: FTY681105@sohu.com; Chen, Dong, E-mail: 857984870@qq.com; Zhang, Pinliang, E-mail: zhangpinliang@163.com; Ren, Ruimei, E-mail: liusg708@qq.com [University of Jinan-Shandong Academy of Medical Science, Department of Radiation Oncology, Shandong Cancer Hospital and Institute, School of Medicine and Life Sciences (China)

    2015-04-15

    ObjectiveThe purpose of our study was to evaluate the diagnostic accuracy of MRI-guided percutaneous transthoracic needle biopsy (PTNB) of solitary pulmonary nodules (SPNs).MethodsRetrospective review of 69 patients who underwent MR-guided PTNB of SPNs was performed. Each case was reviewed for complications. The final diagnosis was established by surgical pathology of the nodule or clinical and imaging follow-up. Pneumothorax rate and diagnostic accuracy were compared between two groups according to nodule diameter (≤2 vs. >2 cm) using χ{sup 2} chest and Fisher’s exact test, respectively.ResultsThe success rate of single puncture was 95.6 %. Twelve (17.4 %) patients had pneumothorax, with 1 (1.4 %) requiring chest tube insertion. Mild hemoptysis occurred in 7 (7.2 %) patients. All of the sample material was sufficient for histological diagnostic evaluation. Pathological analysis of biopsy specimens showed 46 malignant, 22 benign, and 1 nondiagnostic nodule. The final diagnoses were 49 malignant nodules and 20 benign nodules basing on postoperative histopathology and clinical follow-up data. One nondiagnostic sample was excluded from calculating diagnostic performance. A sensitivity, specificity, accuracy, positive predictive value, and negative predictive value in diagnosing SPNs were 95.8, 100, 97.0, 100, and 90.9 %, respectively. Pneumothorax rate, diagnostic sensitivity, and accuracy were not significantly different between the two groups (P > 0.05).ConclusionsMRI-guided PTNB is safe, feasible, and high accurate diagnostic technique for pathologic diagnosis of pulmonary nodules.

  8. Computed tomography-guided percutaneous biopsy of pancreatic masses using pneumodissection

    Directory of Open Access Journals (Sweden)

    Chiang Jeng Tyng

    2013-06-01

    Full Text Available Objective To describe the technique of computed tomography-guided percutaneous biopsy of pancreatic tumors with pneumodissection. Materials and Methods In the period from June 2011 to May 2012, seven computed tomography-guided percutaneous biopsies of pancreatic tumors utilizing pneumodissection were performed in the authors' institution. All the procedures were performed with an automatic biopsy gun and coaxial system with Tru-core needles. The biopsy specimens were histologically assessed. Results In all the cases the pancreatic mass could not be directly approached by computed tomography without passing through major organs and structures. The injection of air allowed the displacement of adjacent structures and creation of a safe coaxial needle pathway toward the lesion. Biopsy was successfully performed in all the cases, yielding appropriate specimens for pathological analysis. Conclusion Pneumodissection is a safe, inexpensive and technically easy approach to perform percutaneous biopsy in selected cases where direct access to the pancreatic tumor is not feasible.

  9. Computed tomography-guided percutaneous biopsy of pancreatic masses using pneumodissection

    International Nuclear Information System (INIS)

    Tyng, Chiang Jeng; Bitencourt, Almir Galvao Vieira; Almeida, Maria Fernanda Arruda; Barbosa, Paula Nicole Vieira; Martins, Eduardo Bruno Lobato; Junior, Joao Paulo Kawaoka Matushita; Chojniak, Rubens; Coimbra, Felipe Jose Fernandez

    2013-01-01

    Objective: to describe the technique of computed tomography-guided percutaneous biopsy of pancreatic tumors with pneumodissection. Materials and methods: in the period from June 2011 to May 2012, seven computed tomography guided percutaneous biopsies of pancreatic tumors utilizing pneumodissection were performed in the authors' institution. All the procedures were performed with an automatic biopsy gun and coaxial system with Tru-core needles. The biopsy specimens were histologically assessed. Results: in all the cases the pancreatic mass could not be directly approached by computed tomography without passing through major organs and structures. The injection of air allowed the displacement of adjacent structures and creation of a safe coaxial needle pathway toward the lesion. Biopsy was successfully performed in all the cases, yielding appropriate specimens for pathological analysis. Conclusion: Pneumodissection is a safe, inexpensive and technically easy approach to perform percutaneous biopsy in selected cases where direct access to the pancreatic tumor is not feasible. (author)

  10. Endoscopic treatment for pancreatic diseases: Needle-knife-guided cannulation via the minor papilla.

    Science.gov (United States)

    Wang, Wei; Gong, Biao; Jiang, Wei-Song; Liu, Lei; Bielike, Kouken; Xv, Bin; Wu, Yun-Lin

    2015-05-21

    To determine the efficacy and safety of meticulous cannulation by needle-knife. Three needle-knife procedures were used to facilitate cannulation in cases when standard cannulation techniques failed. A total of 104 cannulations via the minor papilla attempted in 74 patients at our center between January 2008 and June 2014 were retrospectively reviewed. Standard methods were successful in 79 cannulations. Of the 25 cannulations that could not be performed by standard methods, 19 were performed by needle-knife, while 17 (89.5%) were successful. Needle-knife use improved the success rate of cannulation [76.0%, 79/104 vs 92.3%, (79 + 17)/104; P = 0.001]. When the 6 cases not appropriate for needle-knife cannulation were excluded, the success rate was improved further (80.6%, 79/98 vs 98.0%, 96/98; P = 0.000). There were no significant differences in the rates of post-endoscopic retrograde cholangiopancreatography adverse events between the group using standard methods alone and the group using needle-knife after failure of standard methods (4.7% vs 10.5%, P = 0.301). The needle-knife procedure may be an alternative method for improving the success rate of cannulation via the minor papilla, particularly when standard cannulation has failed.

  11. Disinfection of a probe used in ultrasound-guided prostate biopsy.

    Science.gov (United States)

    Rutala, William A; Gergen, Maria F; Weber, David J

    2007-08-01

    Transrectal ultrasound (TRUS)-guided prostate biopsies are among the most common outpatient diagnostic procedures in urology clinics and carry the risk of introducing pathogens that may lead to infection. To investigate the effectiveness of procedures for disinfecting a probe used in ultrasound-guided prostate biopsy. The effectiveness of disinfection was determined by inoculating 10(7) colony forming units (cfu) of Pseudomonas aeruginosa at the following 3 sites on the probe: the interior lumen of the biopsy needle guide, the outside surface of the biopsy needle guide, and the interior lumen of the ultrasound probe where the needle guide passes through the transducer. Each site was investigated separately. After inoculation, the probe was immersed in 2% glutaraldehyde for 20 minutes and then assessed for the level of microbial contamination. The results demonstrated that disinfection (ie, a reduction in bacterial load of greater than 7 log(10) cfu) could be achieved if the needle guide was removed from the probe. However, if the needle guide was left in the probe channel during immersion in 2% glutaraldehyde, disinfection was not achieved (ie, the reduction was approximately 1 log(10) cfu). Recommendations for probe disinfection are provided and include disassembling the device and immersing the probe and the needle guide separately in a high-level disinfectant.

  12. MRI-Guided Percutaneous Biopsy of Mediastinal Masses Using a Large Bore Magnet: Technical Feasibility

    Energy Technology Data Exchange (ETDEWEB)

    Garnon, J., E-mail: juliengarnon@gmail.com [Nouvel Hôpital Civil, Department of Interventional Radiology (France); Ramamurthy, N., E-mail: nitin-ramamurthy@hotmail.com [Norfolk and Norwich University Hospital, Department of Radiology (United Kingdom); Caudrelier J, J., E-mail: caudjean@yahoo.fr [Nouvel Hôpital Civil, Department of Interventional Radiology (France); Erceg, G., E-mail: erceggorislav@yahoo.com; Breton, E., E-mail: ebreton@unistra.fr [ICube, University of Strasbourg, CNRS (France); Tsoumakidou, G., E-mail: gtsoumakidou@yahoo.com; Rao, P., E-mail: pramodrao@me.com; Gangi, A., E-mail: gangi@unistra.fr [Nouvel Hôpital Civil, Department of Interventional Radiology (France)

    2016-05-15

    ObjectiveTo evaluate the diagnostic accuracy and safety of magnetic resonance imaging (MRI)-guided percutaneous biopsy of mediastinal masses performed using a wide-bore high-field scanner.Materials and MethodsThis is a retrospective study of 16 consecutive patients (8 male, 8 female; mean age 74 years) who underwent MRI-guided core needle biopsy of a mediastinal mass between February 2010 and January 2014. Size and location of lesion, approach taken, time for needle placement, overall duration of procedure, and post-procedural complications were evaluated. Technical success rates and correlation with surgical pathology (where available) were assessed.ResultsTarget lesions were located in the anterior (n = 13), middle (n = 2), and posterior mediastinum (n = 1), respectively. Mean size was 7.2 cm (range 3.6–11 cm). Average time for needle placement was 9.4 min (range 3–18 min); average duration of entire procedure was 42 min (range 27–62 min). 2–5 core samples were obtained from each lesion (mean 2.6). Technical success rate was 100 %, with specimens successfully obtained in all 16 patients. There were no immediate complications. Histopathology revealed malignancy in 12 cases (4 of which were surgically confirmed), benign lesions in 3 cases (1 of which was false negative following surgical resection), and one inconclusive specimen (treated as inaccurate since repeat CT-guided biopsy demonstrated thymic hyperplasia). Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy in our study were 92.3, 100, 100, 66.7, and 87.5 %, respectively.ConclusionMRI-guided mediastinal biopsy is a safe procedure with high diagnostic accuracy, which may offer a non-ionizing alternative to CT guidance.

  13. Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration for Staging of Patients with Non-Small Cell Lung Cancer without Mediastinal Involvement at Positron Emission Tomography-Computed Tomography

    DEFF Research Database (Denmark)

    Naur, Therese Maria Henriette; Konge, Lars; Clementsen, Paul Frost

    2017-01-01

    BACKGROUND: Staging of lung cancer is essential to the treatment, which is curative only in cases of localized disease. Previous studies have suggested that endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is unnecessary when positron emission tomography-computed tomog...

  14. CT-guided biopsy of pulmonary lesions : a comparison of diagnostic accuracy and complication rate between automated gun biopsy and fine needle aspiration biopsy

    International Nuclear Information System (INIS)

    Kim, Keon Woo; Kang, Duk Sik

    1998-01-01

    The purpose of this study is to compare the efficacy and safety of CT-guided automated gun biopsy with those of fine needle aspiration biopsy of pulmonary lesions. Under CT guidance, we performed automated gu biopsies in 115 cases of 109 patients and fine needle aspiration biopsies in 119 cases of 108 patients with pulmonary lesions. Between the two methods, we compared the diagnostic rate, diagnostic accuracy and frequency of compilations according to the depth and diameter of pulmonary lesions. The overall diagnostic rates of automated gun biopsy and fine needle aspiration biopsy were 76.5 % (88/115) and 64.7 % (77/119) respectively. There was a significant statistical difference (p=0.048), especially in the case of malignant lesions less than 3 cm (p=0.027) and more than 6 cm in maximal diameter (p=0.008), and in the lesions located from 1 cm to less than 3 cm from the pleural (p=0.030), as seen on CT. There was no significant statistical difference in the frequency of complications. Automated gun biopsy of pulmonary lesions under CT guidance is safe, with complications rate comparable to those of fine needle aspiration biopsy. A higher overall diagnostic rate can be achieved by automated gun biopsy than by fine needle aspiration biopsy. For the diagnosis of pulmonary lesions under CT guidance, automated gun biopsy is therefore a more useful procedure than fine needle aspiration biopsy. (author). 24 refs., 3 tabs

  15. Paraffin-gel tissue-mimicking material for ultrasound-guided needle biopsy phantom.

    Science.gov (United States)

    Vieira, Sílvio L; Pavan, Theo Z; Junior, Jorge E; Carneiro, Antonio A O

    2013-12-01

    Paraffin-gel waxes have been investigated as new soft tissue-mimicking materials for ultrasound-guided breast biopsy training. Breast phantoms were produced with a broad range of acoustical properties. The speed of sound for the phantoms ranged from 1425.4 ± 0.6 to 1480.3 ± 1.7 m/s at room temperature. The attenuation coefficients were easily controlled between 0.32 ± 0.27 dB/cm and 2.04 ± 0.65 dB/cm at 7.5 MHz, depending on the amount of carnauba wax added to the base material. The materials do not suffer dehydration and provide adequate needle penetration, with a Young's storage modulus varying between 14.7 ± 0.2 kPa and 34.9 ± 0.3 kPa. The phantom background material possesses long-term stability and can be employed in a supine position without changes in geometry. These results indicate that paraffin-gel waxes may be promising materials for training radiologists in ultrasound biopsy procedures. Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  16. Effects of core needle biopsy and subsequent neoadjuvant chemotherapy on molecular alterations and outcome in breast cancer

    Directory of Open Access Journals (Sweden)

    Xie L

    2018-02-01

    Full Text Available Lingmin Xie,1 Xiaolei Li,2 Qinchuan Wang,1 Jichun Zhou,1 Jun Shen,1 Lixi Luo,1 Yi Lu,1 Linbo Wang1 1Division of Surgical Oncology, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Zhejiang, 2Division of Surgical Oncology, The First People’s Hospital of Wenling, Zhejiang, China Objectives: The aim of our study is to evaluate the effect of core needle biopsy (CNB and subsequent neoadjuvant chemotherapy (NAC on the expression of estrogen receptor (ER, progesterone receptor (PR, human epidermal growth hormone receptor 2 (HER2 and Ki67 in breast cancer, and the associated influencing factors.Materials and methods: In this retrospective cohort study, 143 patients with primary operable breast cancer who received NAC were included. ER, PR, HER2 and Ki67 statuses were compared between pretreatment and posttreatment residual samples. A control group of paired core and excision tumors from 123 patients who did not receive NAC within the same study period was also assessed. Data on patients’ clinicopathologic features were collected to identify associated influencing factors.Results: Ki67 value significantly increased in excision tumors compared with paired core samples in controls without presurgery treatment (P<0.01, which was associated with the pathologic lymph node status and the interaction of PR and HER2 status (P=0.008 and 0.028, respectively. In 143 patients who underwent NAC, a significant decrease was observed in the expression of PR and Ki67 after NAC (P=0.003 and P<0.01, respectively. Further subgroup analysis showed that PR decrease was more obvious in premenopausal patients and Luminal A patients (P=0.006 and 0.002, respectively.Conclusion: Core samples could provide more reliable information on determination of molecular subtype than surgical excisions. Decreases in PR and Ki67 expression following NAC could be used as positive prognostic factors. We recommend repeat testing of these biologic markers following NAC for

  17. Medically relevant ElectroNeedle technology development.

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, Carrie Frances; Thomas, Michael Loren; McClain, Jaime L.; Harper, Jason C.; Achyuthan, Komandoor E.; Ten Eyck, Gregory A.

    2008-11-01

    ElectroNeedles technology was developed as part of an earlier Grand Challenge effort on Bio-Micro Fuel Cell project. During this earlier work, the fabrication of the ElectroNeedles was accomplished along with proof-of-concept work on several electrochemically active analytes such as glucose, quinone and ferricyanide. Additionally, earlier work demonstrated technology potential in the field of immunosensors by specifically detecting Troponin, a cardiac biomarker. The current work focused upon fabrication process reproducibility of the ElectroNeedles and then using the devices to sensitively detect p-cresol, a biomarker for kidney failure or nephrotoxicity. Valuable lessons were learned regarding fabrication assurance and quality. The detection of p-cresol was accomplished by electrochemistry as well as using fluorescence to benchmark ElectroNeedles performance. Results from these studies will serve as a guide for the future fabrication processes involving ElectroNeedles as well as provide the groundwork necessary to expand technology applications. One paper has been accepted for publication acknowledging LDRD funding (K. E. Achyuthan et al, Comb. Chem. & HTS, 2008). We are exploring the scope for a second paper describing the applications potential of this technology.

  18. Breath-hold after forced expiration before removal of the biopsy needle decreased the rate of pneumothorax in CT-guided transthoracic lung biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Min, Lingfeng; Xu, Xingxiang [Subei People' s Hospital of Jiangsu Province, Clinical Medical School of Yangzhou University, Yangzhou 225001, Jiangsu (China); Song, Yong [Jinling Hospital, Nanjing University School of Medical, Nanjing 210002, Jiangsu (China); Issahar, Ben-Dov [Pulmonary Institute, Sheba Medical Center, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv (Israel); Wu, Jingtao; Zhang, Le; Huang, Qian [Subei People' s Hospital of Jiangsu Province, Clinical Medical School of Yangzhou University, Yangzhou 225001, Jiangsu (China); Chen, Mingxiang, E-mail: chenmx1129@126.com [Subei People' s Hospital of Jiangsu Province, Clinical Medical School of Yangzhou University, Yangzhou 225001, Jiangsu (China)

    2013-01-15

    Purpose: To assess the effect of a breath-hold after forced expiration on the rate of pneumothorax after computed tomography (CT)-guided transthoracic needle biopsy of pulmonary lesions. Materials and methods: Between January 2008 and December 2011, percutaneous CT-guided lung biopsy was performed in 440 patients. Two hundred and twenty-one biopsies were performed without (control group) and two hundred and nineteen biopsies were performed with (study group) the study maneuver – a breath-hold after forced expiratory approach. Multivariate analysis was performed between groups for risk factors for pneumothorax, including patient demographics, lesion characteristics, and biopsy technique. Results: A reduced number of pneumothoraces (18 [8.2%] vs 35 [15.8%]; P = 0.014) but no significant difference in rate of drainage catheter insertions (2 [0.9%] vs (4 [1.8%]; P = 0.418) were noted in the study group as compared with the control group. By logistic regression analysis, three factors significantly and independently affected the risk for pneumothorax including lesion size (transverse and longitudinal diameter), distance from pleura and utilizing or avoiding the breath-hold after deep expiration maneuver. Conclusion: Breath-holding after forced expiration before removal of the biopsy needle during the percutaneous CT-guided transthoracic lung biopsy almost halved the rate of overall pneumothorax. Small lesion size (longitudinal diameter) and the distance from pleura were also predictors of pneumothorax in our study.

  19. Breath-hold after forced expiration before removal of the biopsy needle decreased the rate of pneumothorax in CT-guided transthoracic lung biopsy

    International Nuclear Information System (INIS)

    Min, Lingfeng; Xu, Xingxiang; Song, Yong; Issahar, Ben-Dov; Wu, Jingtao; Zhang, Le; Huang, Qian; Chen, Mingxiang

    2013-01-01

    Purpose: To assess the effect of a breath-hold after forced expiration on the rate of pneumothorax after computed tomography (CT)-guided transthoracic needle biopsy of pulmonary lesions. Materials and methods: Between January 2008 and December 2011, percutaneous CT-guided lung biopsy was performed in 440 patients. Two hundred and twenty-one biopsies were performed without (control group) and two hundred and nineteen biopsies were performed with (study group) the study maneuver – a breath-hold after forced expiratory approach. Multivariate analysis was performed between groups for risk factors for pneumothorax, including patient demographics, lesion characteristics, and biopsy technique. Results: A reduced number of pneumothoraces (18 [8.2%] vs 35 [15.8%]; P = 0.014) but no significant difference in rate of drainage catheter insertions (2 [0.9%] vs (4 [1.8%]; P = 0.418) were noted in the study group as compared with the control group. By logistic regression analysis, three factors significantly and independently affected the risk for pneumothorax including lesion size (transverse and longitudinal diameter), distance from pleura and utilizing or avoiding the breath-hold after deep expiration maneuver. Conclusion: Breath-holding after forced expiration before removal of the biopsy needle during the percutaneous CT-guided transthoracic lung biopsy almost halved the rate of overall pneumothorax. Small lesion size (longitudinal diameter) and the distance from pleura were also predictors of pneumothorax in our study

  20. C-arm cone-beam CT combined with a new electromagnetic navigation system for guidance of percutaneous needle biopsies. Initial clinical experience

    Energy Technology Data Exchange (ETDEWEB)

    Kickuth, R.; Reichling, C.; Bley, T.; Hahn, D.; Ritter, C. [University Hospital of Wuerzburg (Germany). Inst. of Diagnostic and Interventional Radiology

    2015-07-15

    To evaluate the feasibility and efficacy of C-arm fluoroscopic cone-beam computed tomography (CACT) in combination with a new electromagnetic tracking (EMT) system for needle guidance during percutaneous biopsies. 53 patients were referred for biopsy of thoracic (n = 19) and abdominal (n = 34) lesions. CT-like images of the anatomical region of interest (ROI) were generated using a flat panel-based angiographic system. These images were transmitted to an EMT system. A coaxial puncture needle with a sensor in its tip was connected with the navigation system and tracked into an electromagnetic field created via a field generator. Data generated within this field were merged with the CACT images. On a monitor both the anatomical ROI and needle tip position were displayed to enable precise needle insertion into the target. Through the coaxial needle, biopsy specimens for the histologic evaluation were extracted. Number of representative biopsy samples, number of core biopsies/patient, total procedure time, dose-area product, fluoroscopic time, and complications were recorded. 53 CACT/EMT-guided biopsy procedures were performed, 48 of which (91 %) yielded representative tissue samples. Four core biopsies were obtained from each patient. 40 (75 %) lesions were malignant and 13 (25 %) lesions were benign. The total procedure time was 9 ± 5 min (range, 3 - 23 min), fluoroscopic time was 0.8 ± 0.4 min (range, 0.4 - 2 min). The mean dose-area product (cGy cm{sup 2}) was 7373 (range, 895 - 26 904). The rate of complications (1 pneumothorax, 2 hemoptyses) was 6 %. CACT combined with EMT appears to be a feasible and effective technique for the guidance of percutaneous biopsies with a low rate of therapeutically relevant complications.

  1. C-arm cone-beam CT combined with a new electromagnetic navigation system for guidance of percutaneous needle biopsies. Initial clinical experience

    International Nuclear Information System (INIS)

    Kickuth, R.; Reichling, C.; Bley, T.; Hahn, D.; Ritter, C.

    2015-01-01

    To evaluate the feasibility and efficacy of C-arm fluoroscopic cone-beam computed tomography (CACT) in combination with a new electromagnetic tracking (EMT) system for needle guidance during percutaneous biopsies. 53 patients were referred for biopsy of thoracic (n = 19) and abdominal (n = 34) lesions. CT-like images of the anatomical region of interest (ROI) were generated using a flat panel-based angiographic system. These images were transmitted to an EMT system. A coaxial puncture needle with a sensor in its tip was connected with the navigation system and tracked into an electromagnetic field created via a field generator. Data generated within this field were merged with the CACT images. On a monitor both the anatomical ROI and needle tip position were displayed to enable precise needle insertion into the target. Through the coaxial needle, biopsy specimens for the histologic evaluation were extracted. Number of representative biopsy samples, number of core biopsies/patient, total procedure time, dose-area product, fluoroscopic time, and complications were recorded. 53 CACT/EMT-guided biopsy procedures were performed, 48 of which (91 %) yielded representative tissue samples. Four core biopsies were obtained from each patient. 40 (75 %) lesions were malignant and 13 (25 %) lesions were benign. The total procedure time was 9 ± 5 min (range, 3 - 23 min), fluoroscopic time was 0.8 ± 0.4 min (range, 0.4 - 2 min). The mean dose-area product (cGy cm 2 ) was 7373 (range, 895 - 26 904). The rate of complications (1 pneumothorax, 2 hemoptyses) was 6 %. CACT combined with EMT appears to be a feasible and effective technique for the guidance of percutaneous biopsies with a low rate of therapeutically relevant complications.

  2. Ultrasound-guided fine needle aspiration of thyroid nodules: A consensus statement by the Korean Society of Thyroid Radiology

    International Nuclear Information System (INIS)

    Lee, Young Hen; Baek, Jung Hwan; Jung, So Lyoung; Kwak, Jin Young; Kim, Ji Hoon; Shin, Jung Hee

    2015-01-01

    Ultrasound (US)-guided fine needle aspiration (US-FNA) has played a crucial role in managing patients with thyroid nodules, owing to its safety and accuracy. However, even with US guidance, nondiagnostic sampling and infrequent complications still occur after FNA. Accordingly, the Task Force on US-FNA of the Korean Society of Thyroid Radiology has provided consensus recommendations for the US-FNA technique and related issues to improve diagnostic yield. These detailed procedures are based on a comprehensive analysis of the current literature and from the consensus of experts.

  3. Biopsy system for CT-guided biopsies

    International Nuclear Information System (INIS)

    Onik, G.; Cosman, E.; Wells, T.; Goldberg, H.I.; Moss, A.; Costello, P.; Kane, R.

    1987-01-01

    CT stereotaxic brain biopsies have made brain biopsies safe and minimally invasive. CT-guided biopsies of the body, however, have traditionally used a hand-guidance method. CT biopsy guidance systems for the body have recently become available that have similar capabilities as those of brain biopsy systems. To compare the clinical utility of stereotaxically guided biopsies with hand-guided biopsies, the authors prospectively compared 40 biopsies performed with each method. In the stereotaxic method, a localizor grid was placed on the patient to define a reference point, and a frame was used to guide the needle along the intended path. Computer software programs calculated complex paths from one scan plane to another. Although the results disclosed no significant differences in lesion size or path length between the two groups, the stereotaxically guided biopsies required 75% fewer needle manipulations to hit the intended target. Consequently, the stereotaxically guided biopsies required 40% less time and 80% fewer localization scans to find the biopsy needle than did the hand-guided biopsies

  4. Diagnosis of invasive aspergillus tracheobronchitis facilitated by endobronchial ultrasound-guided transbronchial needle aspiration: a case report

    Directory of Open Access Journals (Sweden)

    Casal Roberto F

    2009-11-01

    Full Text Available Abstract Introduction Invasive pulmonary aspergillosis is the most common form of infection by Aspergillus species among immunocompromised patients. Although this infection frequently involves the lung parenchyma, it is unusual to find it limited to the tracheobronchial tree, a condition known as invasive aspergillus tracheobronchitis. Case presentation A 65 year-old Hispanic man from Bolivia with a history of chronic lymphocytic leukemia developed cough and malaise eight months after having an allogenic stem cell transplant. A computed tomography of the chest revealed an area of diffuse soft tissue thickening around the left main stem bronchus, which was intensely fluorodeoxyglucose-avid on positron emission tomography scanning. An initial bronchoscopic exam revealed circumferential narrowing of the entire left main stem bronchus with necrotic and friable material on the medial wall. Neither aspirates from this necrotic area nor bronchial washing were diagnostic. A second bronchoscopy with endobronchial ultrasound evidenced a soft tissue thickening on the medial aspect of the left main stem bronchus underlying the area of necrosis visible endoluminally. Endobronchial ultrasound-guided transbronchial needle aspiration performed in this area revealed multiple fungal elements suggestive of Aspergillus species. Conclusion We describe the first case of invasive aspergillus tracheobronchitis in which the diagnosis was facilitated by the use of endobronchial ultrasound guided trans-bronchial needle aspiration. To the best of our knowledge, we are also presenting the first positron emission tomography scan images of this condition in the literature. We cautiously suggest that endobronchial ultrasound imaging may be a useful tool to evaluate the degree of invasion and the involvement of vascular structures in these patients prior to bronchoscopic manipulation of the affected areas in an effort to avoid potentially fatal hemorrhage.

  5. Diagenesis of conifer needles in a coastal marine environment

    Science.gov (United States)

    Hedges, John I.; Weliky, K.

    1989-10-01

    Physically intact fir, hemlock and cedar needles were isolated from different horizons of a sediment core from a coastal marine bay (Dabob Bay, Washington State, U.S.A.) and from nearby trees and forest litter. Green fir, hemlock and cedar needles were all characterized by glucose-rich aldose mixtures (~30% of tissue carbon), the production of vanillyl and cinnamyl CuO-derived phenols (~8% of tissue carbon) and the presence of both pinitol and myo-inositol (1-2% of tissue carbon). Needles from forest litter were enriched in lignin phenols and non-glucose aldoses and depleted in glucose and cyclitols. The sediment core contained an average of 10 mg/1 of physically intact fir, hemlock and cedar needles, which occurred in similar relative abundances and accounted for less than 1% of the total nonwoody gymnosperm tissue. Compared to the green and litter counterparts, all sedimentary needles were greatly depleted in cyclitols, glucose and p-coumaric acid and enriched in vanillyl phenol precursors. The degree of elevation of vanillyl phenol yield from the degraded needles was used to estimate minimal carbon losses from the samples, which ranged from near 40% for needle litter to almost 70% for the deepest (~100 years old) sedimentary fir/hemlock samples. Although downcore increases in carbon loss and refractory organic components indicated in situ diagenesis, the bulk of overall degradation occurred either on land or during the first 10-20 years after deposition. Atomic C/N ratios of degraded needles were lower than for green counterparts, but nitrogen was lost overall. These relative changes indicate the following stability series: vanillyl phenols > N > ferulic acid, p-hydroxy phenols, most aldoses and bulk tissue > glucose and p-coumaric acid > cyclitols (near 100% loss). Vanillic acid to vanillin ratios, (Ad/Al)v, of the green fir and hemlock needles were unusually high (0.36-0.38) and decreased downcore. Diagenesis also decreased the cinnamyl/vanillyl phenol ratio

  6. [Case-control study on needle-knife to cut off the medial branch of the lumbar posterior ramus under C-arm guiding for the treatment of low back pain caused by lumbar facet osteoarthritis].

    Science.gov (United States)

    Lu, Di; Xu, Wei-xing; Ding, Wei-Guo; Guo, Qiao-Feng; Ma, Gou-ping; Zhu, Wei-min

    2013-03-01

    To study the clinical efficacy of needle-knife to cut off the medial branch of the lumbar posterior ramus under C-arm guiding to treat low back pain caused by lumbar facet osteoarthritis. From July 2009 to June 2011, 60 patients with low back pain caused by lumbar facet osteoarthritis were reviewed,including 34 males and 26 females, ranging in age from 39 to 73 years old,averaged 61.9 years old; the duration of the disease ranged from 6 to 120 months, with a mean of 18.9 months. All the patients were divided into two groups, 30 patients (18 males and 12 females, ranging in age from 39 to 71 years old, needle-knife group) were treated with needle-knife to cut off medial branch of the lumbar posterior ramus under C -arm guiding and the other 30 patients(16 males and 14 females, ranging in age from 41 to 73 years old, hormone injection group) were treated with hormone injection in lumbar facet joint under C-arm guiding. The preoperative JOA scores and the scores at the 1st, 12th and 26th weeks after treatment were analyzed. Before treatment,the JOA scores between the two groups had no significant difference (P= 0.479); after 1 week of treatment, the JOA scores between the two groups had significant difference (P= 0.040), the improvement rate of hormone injection group was superior than that of the needle-knife group,which were (58.73+/-18.20)% in needle-knife group and (71.10+/-22.19)% in hormone injection group; after 12 weeks of treatment, the JOA scores between the two groups had no significant difference(P=0.569), and the improvement rate between the two groups had no significant difference,which were (50.09+/-19.33)% in the needle-knife group and (48.70+/-18.36)%) in the hormone injection group; after 26 weeks of treatment,the JOA scores between the two groups had significant difference (P=0.000), the improvement rate of hormone injection group was superior than that of the needle-knife group,which were (48.56+/-28.24)% in needle-knife group and (15

  7. MRI-guided trephine biopsy and fine-needle aspiration in the diagnosis of bone lesions in low-field (0.23 T) MRI system using optical instrument tracking

    International Nuclear Information System (INIS)

    Blanco Sequeiros, Roberto; Klemola, Rauli; Ojala, Risto; Jyrkinen, Lasse; Tervonen, Osmo; Lappi-Blanco, Elisa; Soini, Ylermi

    2002-01-01

    The purpose of this study was to evaluate the feasibility of MRI-guided bone biopsy with optical instrument tracking and evaluate advantage of combined fine-needle aspiration (FNA) with trephine biopsy. Twenty trephine bone biopsies and 13 FNAs were performed under MRI and CT guidance in 14 patients. Informed consent was obtained from all patients. The evaluation of diagnostic accuracy was achieved by comparing the histopathological and cytological diagnosis with current or final diagnosis made during 6-month clinical follow-up. A 0.23-T open MRI scanner with interventional tools (Outlook Proview, Marconi Medical Systems, Cleveland, Ohio) was used. A surface coil was used. For trephine biopsy MRI-compatible bone biopsy set (Daum medical, Schwerin, Germany) was used. The FNA was performed with MRI compatible 20-G needle (Cook, Bloomington, Ind.). The diagnostic accuracy of MRI-guided trephine biopsy was 95%. The FNA sample diagnosis concurred with the histological in 54%. Our results show that MRI guidance in bone biopsies is accurate and safe. It is comparable to CT-guided or open biopsy. The role of combined FNA with bone biopsies remains controversial. (orig.)

  8. Imaging-histologic discordance at sonographically guided percutaneous biopsy of breast lesions

    International Nuclear Information System (INIS)

    Kim, Min Jung; Kim, Eun-Kyung; Park, Sun Young; Jung, Hae Kyoung; Park, Byeong-Woo; Kim, Haeryung; Oh, Ki Keun

    2008-01-01

    Objective: To determine the frequency of imaging-histologic discordance at percutaneous breast biopsy and to evaluate differences in clinical and radiologic findings between pathologically upgraded lesions and non-upgraded lesions. Materials and methods: From February 2000 to June 2005, we reviewed 386 cases that had suspicious imaging findings but yielded benign histology at US-core needle biopsy and that underwent subsequent excisional biopsy. In 74 of 386 cases, the benign histology at core needle biopsy could not provide a satisfactory explanation for the radiologically suspicious lesions. The clinical, radiologic and histologic findings were reviewed for those 74 cases that were classified as the upgrade group and the non-upgrade group after excisional biopsy. Results: The upgrade rate was 17.6% (95% confidence interval, 10.6-27.8%, 13 of 74 cases) revealed upgraded pathology at the subsequent excisional biopsy. Besides the size of masses, there were no statistically significant differences in imaging findings between the upgrade and non-upgrade groups at excisional biopsy. Conclusion: This upgrade rate of 17.6% suggests that excisional biopsy or re-biopsy is warranted in those cases presenting imaging-histologic discordance at US-guided core biopsy

  9. Percutaneous core needle biopsies: The yield in spinal tuberculosis

    African Journals Online (AJOL)

    2014-01-29

    Jan 29, 2014 ... abscess formation, which was epidural in 8 and prevertebral in 13. One patient ... To (i) assess the yield of percutaneous needle biopsies; (ii) identify factors that may lead to a negative result; and (iii) determine .... ultimately detected, not testing for drug susceptibility risks a delay of .... Int J Tuberc Lung Dis.

  10. Feasibility of the Less Is More Approach in Treating Low-Risk Ductal Carcinoma In Situ Diagnosed on Core Needle Biopsy: Ten-Year Review of Ductal Carcinoma In Situ Upgraded to Invasion at Surgery.

    Science.gov (United States)

    Podoll, Mirna B; Reisenbichler, Emily S; Roland, Lania; Bruner, Andrew; Mizuguchi, Sarah; Sanders, Mary Ann G

    2018-03-27

    - Ductal carcinoma in situ (DCIS) represents 20% of screen-detected breast cancers. The likelihood that certain types of DCIS are slow growing and may never progress to invasion suggests that our current standards of treating DCIS could result in overtreatment. The LORIS (LOw RISk DCIS) and LORD (LOw Risk DCIS) trials address these concerns by randomizing patients with low-risk DCIS to either active surveillance or conventional treatment. - To determine the upgrade rate of DCIS diagnosed on core needle biopsy to invasive carcinoma at surgery and to evaluate the safety of managing low-risk DCIS with surveillance alone, by characterizing the pathologic and clinical features of upgraded cases and applying criteria of the LORD and LORIS trials to these cases. - A 10-year retrospective analysis of DCIS on core needle biopsy with subsequent surgery. - We identified 1271 cases of DCIS on core needle biopsy: 200 (16%) low grade, 649 (51%) intermediate grade, and 422 (33%) high grade. Of the 1271 cases, we found an 8% upgrade rate to invasive carcinoma (n = 105). Nineteen of the 105 upgraded cases (18%) had positive lymph nodes. Low-grade DCIS was least likely to upgrade to invasion, comprising 10% (10 of 105) of upgraded cases. Three of the 105 upgraded cases (3%) met criteria for the LORD trial, and all were low-grade DCIS on core needle biopsy with favorable biology on follow-up. - There is a clear risk of upgrade to invasion on follow-up excision; however, applying strict criteria of the LORD trial effectively decreases the likelihood of a missed invasive component or missed aggressive pathologic features.

  11. Tracheobronchial puncture-site nodular reaction (TPNR following endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA: Systematic review of case reports

    Directory of Open Access Journals (Sweden)

    Karan Madan

    2017-01-01

    Full Text Available Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA is a minimally invasive and efficacious diagnostic modality for lung cancer staging and evaluation of undiagnosed mediastinal lymphadenopathy. Procedure-related complications are uncommon. We herein report an infrequently described phenomenon following EBUS-TBNA in which two patients developed nodular granulation tissue at the tracheobronchial puncture site. On systematic review, we found description of such phenomena by terminologies such as endobronchial inflammatory polyp, granuloma, and endobronchial mass. The endobronchial inflammatory polyp has been one of the most commonly used terminologies for these; but in most cases, the classical features of an inflammatory polyp are lacking. We propose the term, tracheobronchial puncture-site nodular reaction (TPNR with further classification into granulomatous and nongranulomatous subtypes, for standardized reporting of such reactions following transbronchial needle aspiration procedures. Knowledge of this entity and standardized nomenclature shall help in better characterization of the outcomes and risk factors for the occurrence of these reactions.

  12. Percutaneous CT-guided biopsy of the musculoskeletal system: Results of 2027 cases

    International Nuclear Information System (INIS)

    Rimondi, Eugenio; Rossi, Giuseppe; Bartalena, Tommaso; Ciminari, Rosanna; Alberghini, Marco; Ruggieri, Pietro; Errani, Costantino; Angelini, Andrea; Calabro, Teresa; Abati, Caterina Novella; Balladelli, Alba; Tranfaglia, Cristina; Mavrogenis, Andreas F.; Vanel, Daniel; Mercuri, Mario

    2011-01-01

    Introduction: Biopsy of the musculoskeletal system is useful in the management of bone lesions particularly in oncology but they are often challenging procedures with a significant risk of complications. Computed tomography (CT)-guided needle biopsies may decrease these risks but doubts still exist about their diagnostic accuracy. This retrospective analysis of the experience of a single institution with percutaneous CT-guided biopsy of musculoskeletal lesions evaluates the results of these biopsies for bone lesions either in the appendicular skeleton or in the spine, and defines indications. Materials and methods: We reviewed the results of 2027 core needle biopsies performed over the past 18 years at the authors' institution. The results obtained are subject of this paper. Results: In 1567 cases the correct diagnosis was made with the first CT-guided needle biopsy (77.3% accuracy rate), in 408 cases the sample was not diagnostic and in 52 inadequate. Within 30 days these 408 patients underwent another biopsy, which was diagnostic in 340 cases with a final diagnostic accuracy of 94%. Highest accuracy rates were obtained in primary and secondary malignant lesions. Most false negative results were found in cervical lesions and in benign, pseudotumoral, flogistic, and systemic pathologies. There were 22 complications (18 transient paresis, 3 haematomas, 1 retroperitoneal haematoma) which had no influence on the treatment strategy, nor on patient outcome. Conclusion: This technique is reliable and safe and should be considered nowadays the gold standard for biopsies of the musculoskeletal system.

  13. Transthoracic CT-guided biopsy with multiplanar reconstruction image improves diagnostic accuracy of solitary pulmonary nodules

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Hatabu, Hiroto; Takenaka, Daisuke; Imai, Masatake; Ohbayashi, Chiho; Sugimura, Kazuro

    2004-01-01

    Objective: To evaluate the utility of multiplanar reconstruction (MPR) image for CT-guided biopsy and determine factors of influencing diagnostic accuracy and the pneumothorax rate. Materials and methods: 390 patients with 396 pulmonary nodules underwent transthoracic CT-guided aspiration biopsy (TNAB) and transthoracic CT-guided cutting needle core biopsy (TCNB) as follows: 250 solitary pulmonary nodules (SPNs) underwent conventional CT-guided biopsy (conventional method), 81 underwent CT-fluoroscopic biopsy (CT-fluoroscopic method) and 65 underwent conventional CT-guided biopsy in combination with MPR image (MPR method). Success rate, overall diagnostic accuracy, pneumothorax rate and total procedure time were compared in each method. Factors affecting diagnostic accuracy and pneumothorax rate of CT-guided biopsy were statistically evaluated. Results: Success rates (TNAB: 100.0%, TCNB: 100.0%) and overall diagnostic accuracies (TNAB: 96.9%, TCNB: 97.0%) of MPR were significantly higher than those using the conventional method (TNAB: 87.6 and 82.4%, TCNB: 86.3 and 81.3%) (P<0.05). Diagnostic accuracy were influenced by biopsy method, lesion size, and needle path length (P<0.05). Pneumothorax rate was influenced by pathological diagnostic method, lesion size, number of punctures and FEV1.0% (P<0.05). Conclusion: The use of MPR for CT-guided lung biopsy is useful for improving diagnostic accuracy with no significant increase in pneumothorax rate or total procedure time

  14. A Randomised Clinical Trial to Compare Coaxial and Noncoaxial Techniques in Percutaneous Core Needle Biopsy of Renal Parenchyma

    Energy Technology Data Exchange (ETDEWEB)

    Babaei Jandaghi, Ali [Guilan University of Medical Sciences, Department of Radiology, Poursina Hospital (Iran, Islamic Republic of); Lebady, Mohammadkazem; Zamani, Athar-Alsadat [Guilan University of Medical Sciences, Urology Research Center, Razi Hospital (Iran, Islamic Republic of); Heidarzadeh, Abtin [Guilan University of Medical Sciences, Department of Community Medicine (Iran, Islamic Republic of); Monfared, Ali [Guilan University of Medical Sciences, Urology Research Center, Razi Hospital (Iran, Islamic Republic of); Pourghorban, Ramin, E-mail: ramin-p2005@yahoo.com [Tehran University of Medical Sciences, Department of Radiology, Imam Khomeini Hospital Complex (Iran, Islamic Republic of)

    2017-01-15

    PurposeTo compare the coaxial and noncoaxial techniques of renal parenchymal core needle biopsy.Materials and MethodsThis is an institutional review board-approved randomised controlled trial comparing 83 patients (male, n = 49) who underwent renal parenchymal core biopsy with coaxial method and 83 patients (male, n = 40) with noncoaxial method. The rate of complications, the number of glomerular profiles, and the procedural time were evaluated in a comparison of the two methods. Correlation between the presence of renal parenchymal disease and the rate of complication was also evaluated.ResultsThe procedural time was significantly shorter in the coaxial technique (coaxial group, 5 ± 1 min; noncoaxial group, 14 ± 2 min; p < 0.001). The rates of complications for the coaxial method was significantly lower than the noncoaxial method (coaxial group, 10.8 %; noncoaxial group, 24.1 %; p = 0.025). There was no significant correlation between gender and the rate of complication. The number of glomerular profiles was significantly higher in patents who underwent renal biopsy with the coaxial method (coaxial group, 18.2 ± 9.1; noncoaxial group, 8.6 ± 5.5; p < 0.001). In the whole study population, the rate of complications was significantly higher in patients with a pathologic renal parenchyma compared to those with a normal parenchyma (19/71 vs. 10/95; p = 0.006).ConclusionsRenal parenchymal biopsy using a coaxial needle is a faster and safer method with a lower rate of complications.

  15. A Randomised Clinical Trial to Compare Coaxial and Noncoaxial Techniques in Percutaneous Core Needle Biopsy of Renal Parenchyma

    International Nuclear Information System (INIS)

    Babaei Jandaghi, Ali; Lebady, Mohammadkazem; Zamani, Athar-Alsadat; Heidarzadeh, Abtin; Monfared, Ali; Pourghorban, Ramin

    2017-01-01

    PurposeTo compare the coaxial and noncoaxial techniques of renal parenchymal core needle biopsy.Materials and MethodsThis is an institutional review board-approved randomised controlled trial comparing 83 patients (male, n = 49) who underwent renal parenchymal core biopsy with coaxial method and 83 patients (male, n = 40) with noncoaxial method. The rate of complications, the number of glomerular profiles, and the procedural time were evaluated in a comparison of the two methods. Correlation between the presence of renal parenchymal disease and the rate of complication was also evaluated.ResultsThe procedural time was significantly shorter in the coaxial technique (coaxial group, 5 ± 1 min; noncoaxial group, 14 ± 2 min; p < 0.001). The rates of complications for the coaxial method was significantly lower than the noncoaxial method (coaxial group, 10.8 %; noncoaxial group, 24.1 %; p = 0.025). There was no significant correlation between gender and the rate of complication. The number of glomerular profiles was significantly higher in patents who underwent renal biopsy with the coaxial method (coaxial group, 18.2 ± 9.1; noncoaxial group, 8.6 ± 5.5; p < 0.001). In the whole study population, the rate of complications was significantly higher in patients with a pathologic renal parenchyma compared to those with a normal parenchyma (19/71 vs. 10/95; p = 0.006).ConclusionsRenal parenchymal biopsy using a coaxial needle is a faster and safer method with a lower rate of complications.

  16. Imaging-guided and nonimaging-guided fine needle aspiration of liver lesions: experience with 406 patients.

    Science.gov (United States)

    Edoute, Y; Tibon-Fisher, O; Ben-Haim, S A; Malberger, E

    1991-12-01

    The aim of the present study was to determine the diagnostic accuracy of different modes of fine needle aspiration (FNA) of liver lesions. A total of 492 FNAs were performed on 406 patients in order to confirm or to rule out focal or multifocal neoplastic disease: 29% under ultrasound (US) guidance, 3% with computed tomographic (CT) guidance, 67% preoperatively, and 1% intraoperatively without imaging guidance. Based on histologic, cytologic, and clinical findings, final diagnoses were reached in 387 patients, of whom 264 had malignant liver disease and 123 had benign liver disease. Of 321 aspirations performed in patients with malignant liver disease, the cytologic findings suggested malignancy in 225 (70.1%), suspected malignancy in 25 (7.8%), and did not reveal malignancy in 71 aspirations (22.1%). Among the 123 patients with benign liver disease, the cytologic findings were reported as benign in all but two patients, who had false-positive cytologic findings. The overall sensitivity, specificity, positive, and negative predictive values for cytologic findings were 85.6, 98.4, 99.1, and 76.1%, respectively. The overall diagnostic accuracy was 89.7%. In one patient, fatal intraperitoneal bleeding due to chronic intravascular coagulation complicated the FNA procedure. We conclude that imaging-guided FNA as well as nonguided FNA for cytologic diagnosis of liver lesions are highly accurate and only rarely may be associated with a fatal complication.

  17. CT-guided puncture

    International Nuclear Information System (INIS)

    Noeldge, G.; Richter, G.M.; Grenacher, L.; Brado, M.; Kauffmann, G.W.

    1996-01-01

    Sonographic and CT-guided punctures allow the evaluation of suspected lesions in the head, thorax, abdomen, retroperitoneum and skeletal system. The size of the lesion to be evaluated determines the size and the diameter of the puncture needle. The quantity of the material obtained will be defined by the diameter of the needle, i.e. fine-needle biopsy is more adequate for cytological than for histological evaluation. Strict adherence to the indications and contraindications for puncture and painstaking performance of the procedure go a long why towards minimizing the complications. The advantage of CT-guided puncture, in contrast to an ultrasound-guided procedure, is visualization during the puncture procedure free from overshadowing. This permits punctures of lesions located deep in the thorax or the abdomen which are overshadowed by the lungs, by air in the small or large bowel or by bone structures. Moreover, this technique yields much more information about the tissues and organs surrounding the suspected lesion. This information is much more investigator-related with ultrasoundguided puncture. Therefore, the CT-guided puncture has become mandatory in the evaluation of suspected lesions. Moreover, using the same technique, percutaneous drainage of fluids in the interpleural space, abscesses in organs, hematomas, lymphoceles and urinomas; ablation of metastases; and sympathicolysis can be carried out. CT-guided puncture thus changes from a minimally invasive diagnostic procedure to a minimally invasive therapy. (orig./MG) [de

  18. Radiographer-performed stereotactic needle core biopsy: Making a difference

    Energy Technology Data Exchange (ETDEWEB)

    Dixon, Anne-Marie [School of Health Studies, University of Bradford, Unity Building, 25 Trinity Road, Bradford BD5 0BB (United Kingdom)], E-mail: a.m.dixon@leeds.ac.uk; Dearnley, Christine [School of Health Studies, University of Bradford, Unity Building, 25 Trinity Road, Bradford BD5 0BB (United Kingdom)

    2008-12-15

    This case study describes a qualitative investigation of the experiences of 14 experienced mammography radiographers who successfully undertook a formal programme of education and training in stereotactic needle core biopsy (SNCB) of the breast. They now routinely perform SNCB within symptomatic and screening breast services in a variety of NHS hospitals across the country. All 14 radiographers completed a semi-structured postal questionnaire approximately six months after the end of the course. A tentative theory derived from the data suggests that the professional challenge associated with radiographer-performed SNCB builds personal confidence and effects positive change. Three main categories emerging from the data - challenge, confidence and change are underpinned by two main themes - educational, professional and service drivers that promote the realisation of goals and vision; and personal, peer and external motivation sustained by respect, recognition and reward. SNCB role extension as explored in this study is having a positive and transformational impact on patient users of breast diagnostic clinical services and on the professional health carers providing them. The key drivers for this as identified in the study are a formal educational experience, professional role extension opportunities and the NHS modernisation process. The participants experienced positive change as individuals and as professional breast cancer multidisciplinary team members. Academic and financial rewards, respect and recognition from colleagues across professional disciplines and from patients, were key motivators that sustained the process. This study indicates that radiographer-performed SNCB can help deliver the NHS Plan and the NHS Cancer Plan and in doing so has the potential to improve the working lives of health care professionals and ultimately to improve the quality of care for patients.

  19. Radiographer-performed stereotactic needle core biopsy: Making a difference

    International Nuclear Information System (INIS)

    Dixon, Anne-Marie; Dearnley, Christine

    2008-01-01

    This case study describes a qualitative investigation of the experiences of 14 experienced mammography radiographers who successfully undertook a formal programme of education and training in stereotactic needle core biopsy (SNCB) of the breast. They now routinely perform SNCB within symptomatic and screening breast services in a variety of NHS hospitals across the country. All 14 radiographers completed a semi-structured postal questionnaire approximately six months after the end of the course. A tentative theory derived from the data suggests that the professional challenge associated with radiographer-performed SNCB builds personal confidence and effects positive change. Three main categories emerging from the data - challenge, confidence and change are underpinned by two main themes - educational, professional and service drivers that promote the realisation of goals and vision; and personal, peer and external motivation sustained by respect, recognition and reward. SNCB role extension as explored in this study is having a positive and transformational impact on patient users of breast diagnostic clinical services and on the professional health carers providing them. The key drivers for this as identified in the study are a formal educational experience, professional role extension opportunities and the NHS modernisation process. The participants experienced positive change as individuals and as professional breast cancer multidisciplinary team members. Academic and financial rewards, respect and recognition from colleagues across professional disciplines and from patients, were key motivators that sustained the process. This study indicates that radiographer-performed SNCB can help deliver the NHS Plan and the NHS Cancer Plan and in doing so has the potential to improve the working lives of health care professionals and ultimately to improve the quality of care for patients

  20. Combined Fluoroscopy- and CT-Guided Transthoracic Needle Biopsy Using a C-Arm Cone-Beam CT System: Comparison with Fluoroscopy-Guided Biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Cheung, Joo Yeon; Kim, Yoo Kyung; Shim, Sung Shine; Lim, Soo Mee [School of Medicine, Ewha Womans University, Seoul (Korea, Republic of)

    2011-02-15

    The aim of this study was to evaluate the usefulness of combined fluoroscopy- and CT-guided transthoracic needle biopsy (FC-TNB) using a cone beam CT system in comparison to fluoroscopy-guided TNB (F-TNB). We retrospectively evaluated 74 FC-TNB cases (group A) and 97 F-TNB cases (group B) to compare their respective diagnostic accuracies according to the size and depth of the lesion, as well as complications, procedure time, and radiation dose. The sensitivity for malignancy and diagnostic accuracy for small (< 30 mm in size) and deep ({>=} 50 mm in depth) lesions were higher in group A (91% and 94%, 92% and 94%) than in group B (73% and 81%, 84% and 88%), however not statistically significant (p > 0.05). Concerning lesions {>=} 30 mm in size and < 50 mm in depth, both groups displayed similar results (group A, 91% and 92%, 80% and 87%: group B, 90% and 92%, 86% and 90%). Pneumothorax occurred 26% of the time in group A and 14% for group B. The mean procedure time and patient skin dose were significantly higher in group A (13.6 {+-} 4.0 minutes, 157.1 {+-} 76.5 mGy) than in group B (9.0 {+-} 3.5 minutes, 21.9 {+-} 15.2 mGy) (p < 0.05). Combined fluoroscopy- and CT-guided TNB allows the biopsy of small (< 30 mm) and deep lesions ({>=} 50 mm) with high diagnostic accuracy and short procedure times, whereas F-TNB is still a useful method for large and superficial lesions with a low radiation dose

  1. PVA matches human liver in needle-tissue interaction.

    Science.gov (United States)

    de Jong, Tonke L; Pluymen, Loes H; van Gerwen, Dennis J; Kleinrensink, Gert-Jan; Dankelman, Jenny; van den Dobbelsteen, John J

    2017-05-01

    Medical phantoms can be used to study needle-tissue interaction and to train medical residents. The purpose of this research is to study the suitability of polyvinyl alcohol (PVA) as a liver tissue mimicking material in terms of needle-tissue interaction. Insertions into ex-vivo human livers were used for reference. Six PVA samples were created by varying the mass percentage of PVA to water (4m% and 7m%) and the number of freeze-thaw cycles (1, 2 and 3 cycles, 16hours of freezing at -19°C, 8hours of thawing). The inner needle of an 18 Gauge trocar needle with triangular tip was inserted 13 times into each of the samples, using an insertion velocity of 5 mm/s. In addition, 39 insertions were performed in two ex-vivo human livers. Axial forces on the needle were captured during insertion and retraction and characterized by friction along the needle shaft, peak forces, and number of peak forces per unit length. The concentration of PVA and the number of freeze-thaw cycles both influenced the mechanical interaction between needle and specimen. Insertions into 4m% PVA phantoms with 2 freeze-thaw cycles were comparable to human liver in terms of estimated friction along the needle shaft and the number of peak forces. Therefore, these phantoms are considered to be suitable liver mimicking materials for image-guided needle interventions. The mechanical properties of PVA hydrogels can be influenced in a controlled manner by varying the concentration of PVA and the number of freeze-thaw cycles, to mimic liver tissue characteristics. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. CT Fluoroscopy-Guided Core Biopsy for Diagnosis of Small ({<=} 20 mm) Pulmonary Nodules

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hye Larn; Kim, Yoon Kyung; Woo, Ok Hee; Yong, Hwan Seok; Kang, Eun Young [Dept. of Radiology, Korea University Guro Hospital, Korea University College of Medicine, Seoul (Korea, Republic of); Kim, Hyun Koo [Dept. of Thoracic Surgery, Korea University Guro Hospital, Korea University College of Medicine, Seoul (Korea, Republic of); Shin, Bong Kyung [Dept. of Pathology, Korea University Guro Hospital, Korea University College of Medicine, Seoul (Korea, Republic of)

    2011-10-15

    To evaluate the efficacy of CT fluoroscopy-guided core biopsy of small pulmonary nodules. This study included 62 patients (35 men, 27 women; age range, 36-85 years) that had a small ({<=} 20 mm) pulmonary nodule and underwent CT fluoroscopy-guided core biopsy. The overall diagnostic accuracy and complication rate were calculated. The diagnostic accuracy was compared between two groups according to the nodule size ({<=} 10 mm vs. > 10 mm), and nodule density (solid vs. subsolid). Malignant or premalignant lesions were finally diagnosed in 39 patients; 36 true-positive and three false-negative findings (sensitivity, 92%). A benign lesion was finally diagnosed in 23 patients, with no false-positive results (specificity, 100%). The overall diagnostic accuracy was 95%. The sensitivity and diagnostic accuracy were 85% and 91% for nodules {<=} 10 mm, and 96% and 97% for nodules > 10 mm (p > 0.05). The sensitivity and diagnostic accuracy were 93% and 96% in the solid group and 90% and 92% in the subsolid group (p > 0.05). Seventeen (27%) patients had a pneumothorax and two (3%) required a closed thoracostomy. CT fluoroscopy-guided core biopsy of small pulmonary nodules yields high diagnostic accuracy with acceptable complication rates.

  3. Multicenter randomized controlled trial comparing the performance of 22 gauge versus 25 gauge EUS-FNA needles in solid masses

    DEFF Research Database (Denmark)

    Vilmann, Peter; S?ftoiu, Adrian; Hollerbach, Stephan

    2013-01-01

    Few randomized studies have assessed the clinical performance of 25-gauge (25G) needles compared with 22-gauge (22G) needles during endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) biopsy of intra-abdominal lesions. We aimed to compare the diagnostic yield, as well as performance...

  4. EFFICACY OF IMMUNOHISTOCHEMISTRY IN PROSTATE NEEDLE BIOPSIES

    Directory of Open Access Journals (Sweden)

    Tameem Afroz

    2016-10-01

    Full Text Available BACKGROUND Prostate needle biopsies can pose a major diagnostic challenge when it comes to differentiating adenocarcinoma and its variants from its benign mimics. In needle biopsies, when the suspicious focus is small, morphological features may not suffice to differentiate it from its morphologic mimics like atrophy, basal cell hyperplasia, reactive inflammatory changes, seminal vesicles and adenosis. Immunohistochemical marker for basal cells, p63 and prostate cancer specific marker, Alpha-Methylacyl-CoA Racemase (AMACR help in overcoming such diagnostic dilemmas. MATERIALS AND METHODS We analysed 157 prostate core needle biopsies over a period of 2 years. Routine Hematoxylin and Eosin (H and E sections and immunohistochemical markers for basal cells (p63 and prostate cancer specific marker (AMACR were used. Prospective study was done on prostate needle core biopsies. Biopsy was done under ultrasound guidance with an 18-gauge needle. Biopsy was done in patients with raised serum PSA levels for exclusion of prostate carcinoma. RESULTS Over a period of two years, 157 prostate core needle biopsies were studied. 83 were benign lesions comprising 69 benign prostatic hyperplasias, five basal cell hyperplasias, four granulomatous lesions and three showed atrophic changes. Two biopsies morphologically resembled seminal vesicles. Prostate cancer specific marker, AMACR was negative in all, but two lesions. In these two lesions, it showed weak nonspecific staining. Basal cell marker p63 showed a continuous staining pattern highlighting the basal cells in all the 69 cases of benign prostatic hyperplasia, 5 cases of basal hyperplasia showed positivity in all the hyperplastic basal cells. In the two cases of seminal vesicles, it showed intense basal cell positivity. It showed a discontinuous pattern in two of the four granulomatous lesions and showed a weak, but a continuous staining pattern in the atrophic lesions. 74 were adenocarcinomas; the predominant

  5. Precision grid and hand motion for accurate needle insertion in brachytherapy

    International Nuclear Information System (INIS)

    McGill, Carl S.; Schwartz, Jonathon A.; Moore, Jason Z.; McLaughlin, Patrick W.; Shih, Albert J.

    2011-01-01

    Purpose: In prostate brachytherapy, a grid is used to guide a needle tip toward a preplanned location within the tissue. During insertion, the needle deflects en route resulting in target misplacement. In this paper, 18-gauge needle insertion experiments into phantom were performed to test effects of three parameters, which include the clearance between the grid hole and needle, the thickness of the grid, and the needle insertion speed. Measurement apparatus that consisted of two datum surfaces and digital depth gauge was developed to quantify needle deflections. Methods: The gauge repeatability and reproducibility (GR and R) test was performed on the measurement apparatus, and it proved to be capable of measuring a 2 mm tolerance from the target. Replicated experiments were performed on a 2 3 factorial design (three parameters at two levels) and analysis included averages and standard deviation along with an analysis of variance (ANOVA) to find significant single and two-way interaction factors. Results: Results showed that grid with tight clearance hole and slow needle speed increased precision and accuracy of needle insertion. The tight grid was vital to enhance precision and accuracy of needle insertion for both slow and fast insertion speed; additionally, at slow speed the tight, thick grid improved needle precision and accuracy. Conclusions: In summary, the tight grid is important, regardless of speed. The grid design, which shows the capability to reduce the needle deflection in brachytherapy procedures, can potentially be implemented in the brachytherapy procedure.

  6. Targeted MRI-guided prostate biopsy: are two biopsy cores per MRI-lesion required?

    Energy Technology Data Exchange (ETDEWEB)

    Schimmoeller, L.; Quentin, M.; Blondin, D.; Dietzel, F.; Schleich, C.; Thomas, C.; Antoch, G. [University Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Dusseldorf (Germany); Hiester, A.; Rabenalt, R.; Albers, P.; Arsov, C. [University Dusseldorf, Medical Faculty, Department of Urology, Dusseldorf (Germany); Gabbert, H.E. [University Dusseldorf, Medical Faculty, Department of Pathology, Dusseldorf (Germany)

    2016-11-15

    This study evaluates the feasibility of performing less than two core biopsies per MRI-lesion when performing targeted MR-guided in-bore prostate biopsy. Retrospectively evaluated were 1545 biopsy cores of 774 intraprostatic lesions (two cores per lesion) in 290 patients (66 ± 7.8 years; median PSA 8.2 ng/ml) regarding prostate cancer (PCa) detection, Gleason score, and tumor infiltration of the first (FBC) compared to the second biopsy core (SBC). Biopsies were acquired under in-bore MR-guidance. For the biopsy cores, 491 were PCa positive, 239 of 774 (31 %) were FBC and 252 of 771 (33 %) were SBC (p = 0.4). Patient PCa detection rate based on the FBC vs. SBC were 46 % vs. 48 % (p = 0.6). For clinically significant PCa (Gleason score ≥4 + 3 = 7) the detection rate was 18 % for both, FBC and SBC (p = 0.9). Six hundred and eighty-seven SBC (89 %) showed no histologic difference. On the lesion level, 40 SBC detected PCa with negative FBC (7.5 %). Twenty SBC showed a Gleason upgrade from 3 + 3 = 6 to ≥3 + 4 = 7 (2.6 %) and 4 to ≥4 + 3 = 7 (0.5 %). The benefit of a second targeted biopsy core per suspicious MRI-lesion is likely minor, especially regarding PCa detection rate and significant Gleason upgrading. Therefore, a further reduction of biopsy cores is reasonable when performing a targeted MR-guided in-bore prostate biopsy. (orig.)

  7. Targeted MRI-guided prostate biopsy: are two biopsy cores per MRI-lesion required?

    International Nuclear Information System (INIS)

    Schimmoeller, L.; Quentin, M.; Blondin, D.; Dietzel, F.; Schleich, C.; Thomas, C.; Antoch, G.; Hiester, A.; Rabenalt, R.; Albers, P.; Arsov, C.; Gabbert, H.E.

    2016-01-01

    This study evaluates the feasibility of performing less than two core biopsies per MRI-lesion when performing targeted MR-guided in-bore prostate biopsy. Retrospectively evaluated were 1545 biopsy cores of 774 intraprostatic lesions (two cores per lesion) in 290 patients (66 ± 7.8 years; median PSA 8.2 ng/ml) regarding prostate cancer (PCa) detection, Gleason score, and tumor infiltration of the first (FBC) compared to the second biopsy core (SBC). Biopsies were acquired under in-bore MR-guidance. For the biopsy cores, 491 were PCa positive, 239 of 774 (31 %) were FBC and 252 of 771 (33 %) were SBC (p = 0.4). Patient PCa detection rate based on the FBC vs. SBC were 46 % vs. 48 % (p = 0.6). For clinically significant PCa (Gleason score ≥4 + 3 = 7) the detection rate was 18 % for both, FBC and SBC (p = 0.9). Six hundred and eighty-seven SBC (89 %) showed no histologic difference. On the lesion level, 40 SBC detected PCa with negative FBC (7.5 %). Twenty SBC showed a Gleason upgrade from 3 + 3 = 6 to ≥3 + 4 = 7 (2.6 %) and 4 to ≥4 + 3 = 7 (0.5 %). The benefit of a second targeted biopsy core per suspicious MRI-lesion is likely minor, especially regarding PCa detection rate and significant Gleason upgrading. Therefore, a further reduction of biopsy cores is reasonable when performing a targeted MR-guided in-bore prostate biopsy. (orig.)

  8. A Fresh Cadaver Model for the Instruction of Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules.

    Science.gov (United States)

    McCrary, Hilary C; Faucett, Erynne A; Hurbon, Audriana N; Milinic, Tijana; Cervantes, Jose A; Kent, Sean L; Adamas-Rappaport, William J

    2017-07-01

    Objective The aim of our study is to determine if a fresh cadaver model (FCM) for the instruction of ultrasound (US)-guided fine-needle aspiration (FNA) of thyroid nodules is a practical method for instruction. Study Design Pre- and postinstruction assessment of medical students' ability to perform US-guided FNA of artificially created thyroid nodules placed adjacent to the thyroid gland of a fresh cadaver. Setting University-based fresh cadaver laboratory. Subjects and Methods Study participants included a total of 17 first- and second-year medical students with minimal US training. Technical skills were assessed using a 10-item checklist. In addition, a cognitive assessment regarding the indications, contraindications, and complications of the procedure was completed. A postinstruction assessment was provided for participants 5 weeks after their initial assessment. Differences between pre- and postinstruction assessment scores of technical skills were analyzed using McNemar's test. The mean cognitive knowledge gain was analyzed using a paired 2-sample t test. Results Eight of 10 items on the skills checklist were statistically significant between pre- and postinstruction skills assessment ( P < .05). There was a statistically significant change in cognitive knowledge gain regarding the contraindications of the procedure ( P = .001), but not for indications or complications ( P = .104 and P = .111, respectively). Conclusion US-guided FNA continues to be an important diagnostic procedure in the workup of thyroid nodules, making it an essential skill to integrate into surgical skills lab. Our FCM for the instruction of US-guided FNA is the first of its kind, and this pilot study shows this is a viable method for instruction.

  9. MLESAC Based Localization of Needle Insertion Using 2D Ultrasound Images

    Science.gov (United States)

    Xu, Fei; Gao, Dedong; Wang, Shan; Zhanwen, A.

    2018-04-01

    In the 2D ultrasound image of ultrasound-guided percutaneous needle insertions, it is difficult to determine the positions of needle axis and tip because of the existence of artifacts and other noises. In this work the speckle is regarded as the noise of an ultrasound image, and a novel algorithm is presented to detect the needle in a 2D ultrasound image. Firstly, the wavelet soft thresholding technique based on BayesShrink rule is used to denoise the speckle of ultrasound image. Secondly, we add Otsu’s thresholding method and morphologic operations to pre-process the ultrasound image. Finally, the localization of the needle is identified and positioned in the 2D ultrasound image based on the maximum likelihood estimation sample consensus (MLESAC) algorithm. The experimental results show that it is valid for estimating the position of needle axis and tip in the ultrasound images with the proposed algorithm. The research work is hopeful to be used in the path planning and robot-assisted needle insertion procedures.

  10. The Utility of Endoscopic Ultrasound Guided Fine Needle Aspiration in the Diagnosis of Infectious Diseases—Report of Three Cases

    Directory of Open Access Journals (Sweden)

    Mauro Ajaj Saieg

    2013-01-01

    Full Text Available Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA is a fast and minimally invasive methodology with a crucial impact on patients’ management. It has an important and established role in the diagnosis and staging of mediastinal and abdominal malignancies, but little is discussed in the literature on the usefulness of this technique in the diagnosis of infectious diseases. In the current report, we present three different cases where EUS was essential for reaching the diagnosis of tuberculosis and paracoccidiodomicosis in cases otherwise seen as malignant. In conclusion, EUS was successful not only in obtaining enough cells for morphological analysis, but also for the production of cell blocks and assessment of the presence of the microorganisms by special stains. EUS allied to fine needle biopsy was an important tool in determining diagnoses of enlarged lymph nodes, revealing the diagnosis of infectious diseases in cases otherwise seen as malignant. The wide use of this methodology in cases such as those reported here cannot only rule out malignancy, but also aid critically ill patients by installing early proper therapy without the need for aggressive interventions.

  11. Should fine needle aspiration cytology in breast assessment be abandoned?

    International Nuclear Information System (INIS)

    Litherland, Janet C.

    2002-01-01

    Fine needle aspiration cytology (FNAC) has been used extensively in the U.K. for the diagnosis of breast lesions over the past 15 years. More recently, large gauge needle biopsy has been used to address many of the problems which have been encountered with fine needle aspiration. This paper reviews the evolution of the use of these procedures and the advantages and disadvantages of each. In considering whether to abandon the use of fine needle aspiration cytology in breast assessment, each individual unit should make a decision based upon their own audited results. However, even if FNAC is retained, it is important to be able to complement cytological diagnosis with core biopsy as there are indisputable advantages, e.g. in the diagnosis of mammographically detected microcalcification. As always, a multi-disciplinary approach is ultimately essential for effective patient management. Litherland, J.C. (2002)

  12. Risk factor analysis of pulmonary hemorrhage complicating CT-guided lung biopsy in coaxial and non-coaxial core biopsy techniques in 650 patients

    Energy Technology Data Exchange (ETDEWEB)

    Nour-Eldin, Nour-Eldin A., E-mail: nour410@hotmail.com [Institute for Diagnostic and Interventional Radiology, Johan Wolfgang Goethe – University Hospital, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany); Diagnostic and Interventional Radiology Department, Cairo University Hospital, Cairo (Egypt); Alsubhi, Mohammed [Institute for Diagnostic and Interventional Radiology, Johan Wolfgang Goethe – University Hospital, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany); Naguib, Nagy N. [Institute for Diagnostic and Interventional Radiology, Johan Wolfgang Goethe – University Hospital, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany); Diagnostic and Interventional Radiology Department, Alexandria University Hospital, Alexandria (Egypt); Lehnert, Thomas; Emam, Ahmed; Beeres, Martin; Bodelle, Boris; Koitka, Karen; Vogl, Thomas J.; Jacobi, Volkmar [Institute for Diagnostic and Interventional Radiology, Johan Wolfgang Goethe – University Hospital, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany)

    2014-10-15

    's depth from the pleural surface (p = 0.021 and 0.018 in non-coaxial and coaxial groups respectively), increased distance of traversed lung in the needle track of more than 2.5 cm (p = 0.001 in both groups). Insignificant risk factors were patient's age, gender or emphysema in both groups (p value >0.1 in both groups). Concomitant incidence of pneumothorax was 32.3% (21/65) in non-coaxial group and 36.6% (26/71) in coaxial group. Pulmonary hemorrhage in the majority of cases was treated conservatively. Conclusion: Pulmonary hemorrhage complicating CT-guided core biopsy of pulmonary lesions, showed insignificant difference between coaxial and non-coaxial techniques. Significant risk factors of pulmonary hemorrhage included small and basal lesions, increased lesion's depth from pleural surface, increased length of aerated lung parenchyma crossed by biopsy needle and passing through vessels within the lung during puncture.

  13. Risk factor analysis of pulmonary hemorrhage complicating CT-guided lung biopsy in coaxial and non-coaxial core biopsy techniques in 650 patients

    International Nuclear Information System (INIS)

    Nour-Eldin, Nour-Eldin A.; Alsubhi, Mohammed; Naguib, Nagy N.; Lehnert, Thomas; Emam, Ahmed; Beeres, Martin; Bodelle, Boris; Koitka, Karen; Vogl, Thomas J.; Jacobi, Volkmar

    2014-01-01

    's depth from the pleural surface (p = 0.021 and 0.018 in non-coaxial and coaxial groups respectively), increased distance of traversed lung in the needle track of more than 2.5 cm (p = 0.001 in both groups). Insignificant risk factors were patient's age, gender or emphysema in both groups (p value >0.1 in both groups). Concomitant incidence of pneumothorax was 32.3% (21/65) in non-coaxial group and 36.6% (26/71) in coaxial group. Pulmonary hemorrhage in the majority of cases was treated conservatively. Conclusion: Pulmonary hemorrhage complicating CT-guided core biopsy of pulmonary lesions, showed insignificant difference between coaxial and non-coaxial techniques. Significant risk factors of pulmonary hemorrhage included small and basal lesions, increased lesion's depth from pleural surface, increased length of aerated lung parenchyma crossed by biopsy needle and passing through vessels within the lung during puncture

  14. Comparative study of decomposable and indecomposable biopsy needle in lung puncture biopsy

    International Nuclear Information System (INIS)

    Wang Bo; Sheng Zhanxin; Wen Yamin; Zhang Liping; Wen Zongqiu

    2007-01-01

    Objective: To contrast the clinical practice characteristics with decomposable and indecomposable biopsy needle in the CT-guided lung puncture biopsy. Methods: 50 patients with lung tumour carried on puncture biopsy under the CT guidance were divided in two groups randomly: Group A (25 examples): using the indecomposable BioPinceTM biopsy needle; Group B(25 examples): using the decomposable Precisa or Vitesse biopsy needle. The puncture biopsy organization quantity, the first time puncture success rate, the pathological diagnosis result and the incidence of puncture complication were compared in two groups. Results: More striped structures were gained obviously in group A than in group B: 24/25 and 11/25 respectively (P>0.05), The pathological diagnosis 'serious extrusion amoebocyte and nature undetermined' only occurred in group B. But the first time puncture success rate was lower in group A than in B: 52%(13/25) and 80%(20/25) respectively (P>0.05), The incidence of hemorrhage and pneumothorax in group A was higher slightly: 84% and 72%, 16% and 4% respectively (P>0.05). Conclusion: The indecomposable needle (BioPinceTM) was better in lung puncture biopsy, but the lower first time puncture success rate also increases the risk of operation and complication in some degree because of the structure of the needle. On the contrary, decomposable needle (the Precisa or the Vitesse) was not the best choice in lung puncture biopsy. But it had the original superiority, especially regarding the special patient such as patient with small tumour, thin thoracic wall, bad physique for its nimble operation. It is essential for us to use the two different types of biopsy needle rationally to enhance the level of CT-guided lung puncture biopsy. (authors)

  15. CT-Guided Biopsy of Small Liver Lesions: Visibility, Artifacts, and Corresponding Diagnostic Accuracy

    International Nuclear Information System (INIS)

    Stattaus, Joerg; Kuehl, Hilmar; Ladd, Susanne; Schroeder, Tobias; Antoch, Gerald; Baba, Hideo A.; Barkhausen, Joerg; Forsting, Michael

    2007-01-01

    Purpose. Our study aimed to determine the visibility of small liver lesions during CT-guided biopsy and to assess the influence of lesion visibility on biopsy results. Material and Methods. Fifty patients underwent CT-guided core biopsy of small focal liver lesions (maximum diameter, 3 cm); 38 biopsies were performed using noncontrast CT, and the remaining 12 were contrast-enhanced. Visibility of all lesions was graded on a 4-point-scale (0 = not visible, 1 = poorly visible, 2 = sufficiently visible, 3 = excellently visible) before and during biopsy (with the needle placed adjacent to and within the target lesion). Results. Forty-three biopsies (86%) yielded diagnostic results, and seven biopsies were false-negative. In noncontrast biopsies, the rate of insufficiently visualized lesions (grades 0-1) increased significantly during the procedure, from 10.5% to 44.7%, due to needle artifacts. This resulted in more (17.6%) false-negative biopsy results compared to lesions with good visualization (4.8%), although this difference lacks statistical significance. Visualization impairment appeared more often with an intercostal or subcostal vs. an epigastric access and with a subcapsular vs. a central lesion location, respectively. With contrast-enhanced biopsy the visibility of hepatic lesions was only temporarily improved, with a risk of complete obscuration in the late phase. Conclusion. In conclusion, visibility of small liver lesions diminished significantly during CT-guided biopsy due to needle artifacts, with a fourfold increased rate of insufficiently visualized lesions and of false-negative histological results. Contrast enhancement did not reveal better results

  16. Chest Computed Tomography (CT) Immediately after CT-Guided Transthoracic Needle Aspiration Biopsy as a Predictor of Overt Pneumothorax

    Science.gov (United States)

    Noh, Tae June; Lee, Chang Hoon; Kang, Young Ae; Kwon, Sung-Youn; Yoon, Ho-Il; Kim, Tae Jung; Lee, Kyung Won; Lee, Jae Ho

    2009-01-01

    Background/Aims This study examined the correlation between pneumothorax detected by immediate post-transthoracic needle aspiration-biopsy (TTNB) chest computed tomography (CT) and overt pneumothorax detected by chest PA, and investigated factors that might influence the correlation. Methods Adult patients who had undergone CT-guided TTNB for lung lesions from May 2003 to June 2007 at Seoul National University Bundang Hospital were included. Immediate post-TTNB CT and chest PA follow-up at 4 and 16 hours after CT-guided TTNB were performed in 934 patients. Results Pneumothorax detected by immediate chest CT (CT-pneumothorax) was found in 237 (25%) and overt pneumothorax was detected by chest PA follow-up in 92 (38.8%) of the 237 patients. However, overt pneumothorax was found in 18 (2.6%) of the 697 patients without CT-pneumothorax. The width and depth of CT-pneumothorax were predictive risk factors for overt pneumothorax. Conclusions CT-pneumothorax is very sensitive for predicting overt pneumothorax, and the width and depth on CT-pneumothorax are reliable risk factors for predicting overt pneumothorax. PMID:19949733

  17. Musculoskeletal ultrasound: how to treat calcific tendinitis of the rotator cuff by ultrasound-guided single-needle lavage technique.

    Science.gov (United States)

    Lee, Kenneth S; Rosas, Humberto G

    2010-09-01

    The purpose of this video article is to illustrate the ultrasound appearance of calcium deposition in the rotator cuff and provide a detailed step-by-step protocol for performing the ultrasound-guided single-needle lavage technique for the treatment of calcific tendinitis with emphasis on patient positioning, necessary supplies, real-time lavage technique, and steroid injection into the subacromial subdeltoid bursa. Musculoskeletal ultrasound is well established as a safe, cost-effective imaging tool in diagnosing and treating common musculoskeletal disorders. Calcific tendinitis of the rotator cuff is a common disabling cause of shoulder pain. Although most cases are self-limiting, a subset of patients is refractory to conservative therapy and requires treatment intervention. Ultrasound-guided lavage is an effective and safe minimally-invasive treatment not readily offered in the United States as an alternative to surgery, perhaps because of the limited prevalence of musculoskeletal ultrasound programs and limited training. On completion of this video article, the participant should be able to develop an appropriate diagnostic and therapeutic algorithm for the treatment of calcific tendinitis of the rotator cuff using ultrasound.

  18. Painful percutaneous transthoracic needle biopsy of Schwannoma: a case report

    International Nuclear Information System (INIS)

    Kim, Sung Hoon; Chun, Kyung Ah; Kim, Young Joo; Park, Seog Hee; Shin, Kyung Sub; Lee, Eun Jung

    1995-01-01

    Percutaneous aspiration needle biopsy of the intrathoracic disease is a safe, easy, and accurate diagnostic method. It usually causes mild pain or discomfort during the procedure. We had a patient who complained of severe sharp pain, well localized at the biopsy site of the target mass during CT-guided transthoracic aspiration biopsy. It was pathologically confirmed as an intrathoracic schwannoma after special staining. To our knowledge, there has been no published report of such a painful percutaneous needle biopsy in a patient with schwannoma in Korea. Two cases were reported in other radiologic journals. The severe sharp pain developed during the transthoracic aspiration needle biopsy is a reliable sign of neurogenic tumor, therefore the participating radiologist should recommend specific immumochemical stain for neurogenic tumor to pathologist

  19. Optimal needle arrangement for intraoperative planning in permanent I-125 prostate implants

    International Nuclear Information System (INIS)

    Thompson, S.A.; Fung, A.Y.C.; Zaider, M.

    2002-01-01

    One limitation of intraoperative planning of permanent prostate implants is that needles must already be in the gland before planning images are acquired. Improperly placed needles often restrict the capability of generating optimal seed placement. We developed guiding principles for the proper layout of needles within the treatment volume. The Memorial Sloan-Kettering Cancer Center planning system employs a genetic algorithm to find the optimal seed implantation pattern consistent with pre-assigned constraints (needle geometry, uniformity, conformity and the avoidance of high doses to urethra and rectum). Ultrasound volumes for twelve patients with I-125 implants were used to generate six plans per patient (total 72 plans) with different needle arrangements. The plans were evaluated in terms of V100 (percentage prostate volume receiving at least the prescription dose), U135 (percentage urethra volume receiving at least 135% of prescription dose), and CI (conformity index, the ratio of treatment volume to prescription dose volume.) The method termed POSTCTR, in which needles were placed on the periphery of the largest ultrasound slice and posterior central needles were placed as needed, consistently gave superior results for all prostate sizes. Another arrangement, labelled POSTLAT, where the needles were placed peripherally with additional needles in the posterior lateral lobes, also gave satisfactory results. We advocate two needle arrangements, POSTCTR and POSTLAT, with the former giving better results. (author)

  20. Optimal needle arrangement for intraoperative planning in permanent I-125 prostate implants

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, S.A. [Department of Medical Physics, North Shore-Long Island Jewish Health System, Manhassett, NY (United States); Fung, A.Y.C.; Zaider, M. [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY (United States)

    2002-08-21

    One limitation of intraoperative planning of permanent prostate implants is that needles must already be in the gland before planning images are acquired. Improperly placed needles often restrict the capability of generating optimal seed placement. We developed guiding principles for the proper layout of needles within the treatment volume. The Memorial Sloan-Kettering Cancer Center planning system employs a genetic algorithm to find the optimal seed implantation pattern consistent with pre-assigned constraints (needle geometry, uniformity, conformity and the avoidance of high doses to urethra and rectum). Ultrasound volumes for twelve patients with I-125 implants were used to generate six plans per patient (total 72 plans) with different needle arrangements. The plans were evaluated in terms of V100 (percentage prostate volume receiving at least the prescription dose), U135 (percentage urethra volume receiving at least 135% of prescription dose), and CI (conformity index, the ratio of treatment volume to prescription dose volume.) The method termed POSTCTR, in which needles were placed on the periphery of the largest ultrasound slice and posterior central needles were placed as needed, consistently gave superior results for all prostate sizes. Another arrangement, labelled POSTLAT, where the needles were placed peripherally with additional needles in the posterior lateral lobes, also gave satisfactory results. We advocate two needle arrangements, POSTCTR and POSTLAT, with the former giving better results. (author)

  1. Sonographically guided percutaneous muscle biopsy in diagnosis of neuromuscular disease: a useful alternative to open surgical biopsy.

    Science.gov (United States)

    O'Sullivan, Paul J; Gorman, Grainne M; Hardiman, Orla M; Farrell, Michael J; Logan, P Mark

    2006-01-01

    The purpose of this study was to evaluate the feasibility of sonographically guided percutaneous muscle biopsy in the investigation of neuromuscular disorders. Sonographically guided percutaneous needle biopsy of skeletal muscle was performed with a 14-gauge core biopsy system in 40 patients over a 24-month period. Patients were referred from the Department of Neurology under investigation for neuromuscular disorders. Sonography was used to find suitable tissue and to avoid major vascular structures. A local anesthetic was applied below skin only. A 3- to 4-mm incision was made. Three 14-gauge samples were obtained from each patient. All samples were placed on saline-dampened gauze and sent for neuropathologic analysis. As a control, we retrospectively assessed results of the 40 most recent muscle samples acquired via open surgical biopsy. With the use of sonography, 32 (80%) of 40 patients had a histologic diagnosis made via percutaneous needle biopsy. This included 26 (93%) of 28 patients with acute muscular disease and 6 (50%) of 12 patients with chronic disease. In the surgical group (all acute disease), 38 (95%) of 40 patients had diagnostic tissue attained. Sonographically guided percutaneous 14-gauge core skeletal muscle biopsy is a useful procedure, facilitating diagnosis in acute muscular disease. It provides results comparable with those of open surgical biopsy in acute muscular disease. It may also be used in chronic muscular disease but repeated or open biopsy may be needed.

  2. Pseudoangiomatous Stromal Hyperplasia in Core Needle Biopsies of Breast Specimens.

    Science.gov (United States)

    Kelten Talu, Canan; Boyaci, Ceren; Leblebici, Cem; Hacihasanoglu, Ezgi; Bozkurt, Erol Rustu

    2017-02-01

    Pseudoangiomatous stromal hyperplasia (PASH) is a benign lesion of myofibroblasts that is composed of a network of slit-like channels that resemble vascular spaces. The aims of this study were to document the frequency of PASH in core needle biopsy specimens (CNBS) of the breast, to describe which histopathologic findings coexist with PASH and to examine any endothelial cell differentiation. We reevaluated hematoxylin and eosin-stained sections of all CNBS that were obtained during a 1-year period. First, we performed CD34 and CD31 immunostainings to highlight the areas of PASH, then performed D2-40/podoplanin (lymphatic endothelial marker) and Fli-1 (vascular endothelial cell marker) immunostains. The total number of CNBS was 412. Areas of PASH were noted in 37 of the 412 cases (9%), with a mean age of 38.5 years. The lesions that were described in association with PASH were "benign breast parenchyma with stromal fibrosis" (17/37; 46%), "fibroepithelial tumors" (17/37; 46%), "columnar cell changes (CCC)" (2/37; 5%), and "invasive carcinoma" (1/37; 3%). There were 2 cases of CCC within the foci of PASH (direct contact with PASH), and 8 additional cases of CCC that coexisted in the same specimen but were not in direct contact. There was no staining for D2-40 or Fli-1 within PASH foci. PASH lesions occurred with a frequency of 9% in CNBS and were mostly in association with benign breast lesions in premenopausal women. CCC was determined as an accompanying epithelial lesion within or near PASH areas. No obvious immunopositivity compatible with endothelial cell differentiation was revealed.

  3. Ultrasound guided percutaneous fine needle aspiration biopsy ...

    African Journals Online (AJOL)

    2011-06-15

    Jun 15, 2011 ... guided PFNAB/US-guided PNCB was the diagnostic test in 23.33% cases. It confirmed a highly ..... provides guidance in multiple axial, longitudinal and .... Source of Support: Nil, Con.ict of Interest: None declared. Gani, et al.

  4. Technical note: CT-guided biopsy of lung masses using an automated guiding apparatus

    International Nuclear Information System (INIS)

    Chellathurai, Amarnath; Kanhirat, Saneej; Chokkappan, Kabilan; Swaminathan, Thiruchendur S; Kulasekaran, Nadhamuni

    2009-01-01

    Automated guiding apparatuses for CT-guided biopsies are now available. We report our experience with an indigenous system to guide lung biopsies. This system gave results similar to those with the manual technique. Automated planning also appears to be technically easier, it requires fewer number of needle passes, consumes less time, and requires fewer number of check scans

  5. Eosinophilic esophageal myositis diagnosed by endoscopic ultrasound-guided fine-needle aspiration biopsy: a case report.

    Science.gov (United States)

    Igarashi, Ryo; Irisawa, Atsushi; Shibukawa, Goro; Yamabe, Akane; Fujisawa, Mariko; Sato, Ai; Maki, Takumi; Arakawa, Noriyuki; Yoshida, Yoshitsugu; Yamamoto, Shogo; Ikeda, Tsunehiko

    2016-10-01

    Eosinophilic esophagitis (EoE) is diagnosed by microscopic findings of eosinophilic infiltration into the squamous epithelium. In contrast, another disease concept termed "eosinophilic esophageal myositis (EoEM)" has been proposed, whereby there is eosinophilic infiltration into the muscularis propria instead. A 60-year-old man was referred to our hospital for chest pain, dysphagia, and several episodes of esophageal food impaction. Although EoE was suspected based on clinical features, biopsy specimens showed no mucosal eosinophilic infiltration. Endoscopic ultrasound (EUS) showed thickening of the muscularis propria layer and subsequent EUS-guided fine-needle aspiration biopsy (EUS-FNA) revealed eosinophilic infiltration into the muscularis propria. Although the patient's symptoms gradually improved after steroid administration, complete remission was not achieved after 1 year of treatment. This case may reflect a disorder distinct from typical EoE based on eosinophilic infiltration of the muscularis propria but not the squamous epithelium, and we, therefore, diagnosed it as EoEM using the EUS-FNA findings as reference.

  6. Bone biopsy needles. Mechanical properties, needle design and specimen quality

    International Nuclear Information System (INIS)

    Keulers, Annika; Penzkofer, T.; Cunha-Cruz, V.C.; Bruners, P.; Helmholtz Inst. fuer biomedizinische Technik, Aachen; Braunschweig, T.; Schmitz-Rode, T.; Mahnken, A.; Helmholtz Inst. fuer biomedizinische Technik, Aachen

    2011-01-01

    To quantitatively analyze differences in mechanical properties, needle design including signs of wear, subjective handling and specimen quality of bone biopsy needles. Materials and Methods: In this study 19 different bone biopsy systems (total 38; 2 /type) were examined. With each biopsy needle five consecutive samples were obtained from vertebral bodies of swine. During puncture a force-torques sensor measured the mechanical properties and subjective handling was assessed. Before and after each biopsy the needles were investigated using a profile projector and signs of wear were recorded. Afterwards, a pathologist semi-quantitatively examined the specimen regarding sample quality. The overall evaluation considered mechanical properties, needle wear, subjective handling and sample quality. Differences were assessed for statistical significance using ANOVA and t-test. Results: Needle diameter (p = 0.003) as well as needle design (p = 0.008) affect the mechanical properties significantly. Franseen design is significantly superior to other needle designs. Besides, length reduction recorded by the profile projector, as a quality criterion showed notable distinctions in between the needle designs. Conclusion: Bone biopsy needles vary significantly in performance. Needle design has an important influence on mechanical properties, handling and specimen quality. Detailed knowledge of those parameters would improve selecting the appropriate bone biopsy needle. (orig.)

  7. Endobronchial ultrasound elastography: a new method in endobronchial ultrasound-guided transbronchial needle aspiration.

    Science.gov (United States)

    Jiang, Jun-Hong; Turner, J Francis; Huang, Jian-An

    2015-12-01

    TBNA through the flexible bronchoscope is a 37-year-old technology that utilizes a TBNA needle to puncture the bronchial wall and obtain specimens of peribronchial and mediastinal lesions through the flexible bronchoscope for the diagnosis of benign and malignant diseases in the mediastinum and lung. Since 2002, the Olympus Company developed the first generation ultrasound equipment for use in the airway, initially utilizing an ultrasound probe introduced through the working channel followed by incoroporation of a fixed linear ultrasound array at the distal tip of the bronchoscope. This new bronchoscope equipped with a convex type ultrasound probe on the tip was subsequently introduced into clinical practice. The convex probe (CP)-EBUS allows real-time endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) of mediastinal and hilar lymph nodes. EBUS-TBNA is a minimally invasive procedure performed under local anesthesia that has been shown to have a high sensitivity and diagnostic yield for lymph node staging of lung cancer. In 10 years of EBUS development, the Olympus Company developed the second generation EBUS bronchoscope (BF-UC260FW) with the ultrasound image processor (EU-M1), and in 2013 introduced a new ultrasound image processor (EU-M2) into clinical practice. FUJI company has also developed a curvilinear array endobronchial ultrasound bronchoscope (EB-530 US) that makes it easier for the operator to master the operation of the ultrasonic bronchoscope. Also, the new thin convex probe endobronchial ultrasound bronchoscope (TCP-EBUS) is able to visualize one to three bifurcations distal to the current CP-EBUS. The emergence of EBUS-TBNA has also been accompanied by innovation in EBUS instruments. EBUS elastography is, then, a new technique for describing the compliance of structures during EBUS, which may be of use in the determination of metastasis to the mediastinal and hilar lymph nodes. This article describes these new EBUS

  8. CT-guided diagnostic interventions for classification of focal hepatic lesions: A comparison of 14 G- and 18 G-large bore cutting needles; CT-gesteuerte perkutane Biopsien zur Klassifizierung von fokalen Leberlaesionen: Vergleich zwischen 14 G- und 18 G-Stanzbiopsienadeln

    Energy Technology Data Exchange (ETDEWEB)

    Haage, P.; Piroth, W.; Staatz, G.; Adam, G.; Guenther, R.W. [Klinik fuer Radiologische Diagnostik, Universitaetsklinikum der RWTH Aachen (Germany)

    1999-07-01

    Purpose: Analysis and comparison of CT-guided 14- and 18-gauge cutting needle biopsies to accurately assess focal liver disease. Methods: The data of 272 CT-guided biopsies in 268 patients were evaluated retrospectively with regard to sensitivity, specificity and complication rate of the chosen needle caliber in differentiating between benign and malignant disease as well as in the ability to determine specific cell types in the various disorders. A 14-gauge (G) needle was used in 101 (37.1%) cases, in 18-g needle biopsy was performed in 171 (62.9%) cases. The Fisher exact test was employed for statistical analysis. Results: Cutting needle biopsy yielded sufficient histologic material in 267 of 272 (98.2%) cases. Correct diagnosis of malignancy was established in 178 of 191 (93.2%) lesions, 73 of 76 (96.1%) disorders were accurately defined as benign, resulting in an overall value of 94.0% (251 of 267). Of these 251 biopsies a definite histological diagnosis could be determined in 90.6% of the cases employing a 14 G needle and in 90.3% using an 18-g needle. The sensitivity, specificity and rate of complications were 94.8%, 92.0%%, 3.0% for the 14-g needle and 92.7%, 97.6%, 0.6% for the 18-g needle, respectively. There were no statistically significant differences with regard to the needle size. Conclusions: CT-guided biopsy of hepatic lesions with the 18-g biopsy needle is of equivalent diagnostic accuracy when compared with the 14-g needle. (orig.) [Deutsch] Ziel: Analyse und Vergleich CT-gesteuerter Fein- und Grobstanzbiopsien zur definitiven Abklaerung unklarer fokaler Leberveraenderungen. Methoden: Die Daten von insgesamt 272 CT-gefuehrten Punktionen an 268 Patienten wurden retrospektiv hinsichtlich Sensitivitaet, Spezifitaet und Komplikationsrate zur Dignitaetsbestimmung und Faehigkeit zur artdiagnostischen Einordnung unter Beruecksichtigung der Groesse der gewaehlten Punktionsnadel ueberprueft und ausgewertet. In 101 (37,1%) Faellen wurde eine 14 Gauge (G

  9. Sono-Guided Percutaneous Automated Gun Biopsy in Pediatric Renal Disease

    International Nuclear Information System (INIS)

    Kim, Jong Chul

    1996-01-01

    To evaluate whether sono-guided percutaneous automated gun biopsy is also useful in pediatricpatients with renal diseases. In the prone position of twenty pediatric patients with renal parenchymal diseases, percutaneous biopsy was done through lateral aspect of the lower pole of left kidney with automated biopsy gun under the guidance of ultrasonography. The biopsy needle was either of 18 or 20 gauge. The obtained core of renal tissue was examined with light, immunofluorescent or electron microscope by the renal pathologist. In 18 among 20 patients, adequate renal tissue core sufficient to be pathologically diagnosed was obtained. The histologic findings were as follows : IG A nephropathy (n = 2), lupus nephritis (n =2), minimal change glomerulonephritis (n = 5), membranoproliferative glomerulonephritis (n = 3), mesangialproliferative glomeru-lonephritis (n = 1), diffuse proliferative glomerulonephritis (n = 3), focalglomerulo-sclerosis (n = 1), membranous glomerulopathy (n = 1). No significant complications occurred during or after the biopsy. Sono-guided percutaneous renal biopsy using automated biopsy gun is also useful todiagnose renal parenchymal diseases without significant complications in pediatric patients

  10. Preclinical evaluation of an MRI-compatible pneumatic robot for angulated needle placement in transperineal prostate interventions

    Science.gov (United States)

    Tokuda, Junichi; Song, Sang-Eun; Fischer, Gregory S.; Iordachita, Iulian; Seifabadi, Reza; Cho, Bong Joon; Tuncali, Kemal; Fichtinger, Gabor; Tempany, Clare M.; Hata, Nobuhiko

    2013-01-01

    Purpose To evaluate the targeting accuracy of a small profile MRI-compatible pneumatic robot for needle placement that can angulate a needle insertion path into a large accessible target volume. Methods We extended our MRI-compatible pneumatic robot for needle placement to utilize its four degrees-of-freedom (4-DOF) mechanism with two parallel triangular structures and support transperineal prostate biopsies in a closed-bore magnetic resonance imaging (MRI) scanner. The robot is designed to guide a needle towards a lesion so that a radiologist can manually insert it in the bore. The robot is integrated with navigation software that allows an operator to plan angulated needle insertion by selecting a target and an entry point. The targeting error was evaluated while the angle between the needle insertion path and the static magnetic field was between −5.7° and 5.7° horizontally and between −5.7° and 4.3° vertically in the MRI scanner after sterilizing and draping the device. Results The robot positioned the needle for angulated insertion as specified on the navigation software with overall targeting error of 0.8 ± 0.5 mm along the horizontal axis and 0.8 ± 0.8 mm along the vertical axis. The two-dimensional root-mean-square targeting error on the axial slices as containing the targets was 1.4 mm. Conclusions Our preclinical evaluation demonstrated that the MRI-compatible pneumatic robot for needle placement with the capability to angulate the needle insertion path provides targeting accuracy feasible for clinical MRI-guided prostate interventions. The clinical feasibility has to be established in a clinical study. PMID:22678723

  11. Fine-needle aspirate cytology suggesting hepatic lipidosis in four cats with infiltrative hepatic disease.

    Science.gov (United States)

    Willard, M D; Weeks, B R; Johnson, M

    1999-12-01

    Four cats are reported in which cytology smears obtained by ultrasound-guided fine needle aspiration of the liver were interpreted as indicative of hepatic lipidosis. However, histopathology of hepatic tissue samples obtained with Tru-Cut-like needles or wedge biopsy revealed that the cats had inflammatory or neoplastic hepatic disease causing their clinical signs. Fine needle aspiration and cytology may not detect infiltrative lesions, particularly those that are nodular, multifocal, or localised around the portal regions. Fine needle aspirate cytology is a useful diagnostic procedure with many advantages, but care must be taken to avoid diagnosing hepatic lipidosis as the cause of illness when an infiltrative lesion is responsible. Copyright 1999 European Society of Feline Medicine.

  12. A rare constellation of empyema, lung abscess, and mediastinal abscess as a complication of endobronchial ultrasound-guided transbronchial needle aspiration.

    Science.gov (United States)

    Huang, Chun-Ta; Chen, Chung-Yu; Ho, Chao-Chi; Yu, Chong-Jen

    2011-07-01

    The introduction of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) brought about significant advancement in the field of bronchoscopy. The major indications for EBUS-TBNA are lung cancer staging and diagnosis of mediastinal lymphadenopathy. This procedure is minimally invasive and cost saving, and no complications have been described in large-scale studies. In this report, we present a case of empyema, lung abscess, and mediastinal abscess that developed in a patient undergoing EBUS-TBNA; the patient subsequently recovered uneventfully after aggressive surgical debridement and antimicrobial therapy. Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  13. NOTE: Optimal needle arrangement for intraoperative planning in permanent I-125 prostate implants

    Science.gov (United States)

    Thompson, S. A.; Fung, A. Y. C.; Zaider, M.

    2002-08-01

    One limitation of intraoperative planning of permanent prostate implants is that needles must already be in the gland before planning images are acquired. Improperly placed needles often restrict the capability of generating optimal seed placement. We developed guiding principles for the proper layout of needles within the treatment volume. The Memorial Sloan-Kettering Cancer Center planning system employs a genetic algorithm to find the optimal seed implantation pattern consistent with pre-assigned constraints (needle geometry, uniformity, conformity and the avoidance of high doses to urethra and rectum). Ultrasound volumes for twelve patients with I-125 implants were used to generate six plans per patient (total 72 plans) with different needle arrangements. The plans were evaluated in terms of V100 (percentage prostate volume receiving at least the prescription dose), U135 (percentage urethra volume receiving at least 135% of prescription dose), and CI (conformity index, the ratio of treatment volume to prescription dose volume.) The method termed POSTCTR, in which needles were placed on the periphery of the largest ultrasound slice and posterior central needles were placed as needed, consistently gave superior results for all prostate sizes. Another arrangement, labelled POSTLAT, where the needles were placed peripherally with additional needles in the posterior lateral lobes, also gave satisfactory results. We advocate two needle arrangements, POSTCTR and POSTLAT, with the former giving better results.

  14. Investigation on Guided-Mode Characteristics of Hollow-Core Photonic Crystal Fibre at Near-Infrared Wavelengths

    International Nuclear Information System (INIS)

    Jin-Hui, Yuan; Chong-Xiu, Yu; Xin-Zhu, Sang; Wen-Jing, Li; Gui-Yao, Zhou; Shu-Guang, Li; Lan-Tian, Hou

    2009-01-01

    Guided-mode characteristics of hollow-core photonic crystal fibre (HC-PCF) are experimentally and theoretically investigated. The transmission spectrum in the range from 755 to 845 nm is observed and the loss is measured to be 0.12 dB/m at 800 nm by cut-back method. Based on the full-vector beam propagation method and the full-vector plane-wave method, the characteristics of mode field over propagation distance 1 m are simulated, and the results show that the propagation efficiency can be above 80%. Compared with the fundamental guided mode well confined in air core within shorter propagation distance, the second-order guided mode leaks into the cladding region and gradually attenuates due to larger refractive index difference. The primary loss factors in HC-PCF and the corresponding solutions are elementarily discussed. (fundamental areas of phenomenology (including applications))

  15. Usefulness of CT-guided automatic needle biopsy of solitary pulmonary nodule smaller than 15 mm

    International Nuclear Information System (INIS)

    Jin, Gong Yong; Lim, Yeong Su

    2004-01-01

    To evaluate the usefulness of the CT-guided percutaneous lung biopsy for the solitary pulmonary nodules smaller than 15 mm in diameter. Between April 2002 and May 2003, we evaluated twenty-five patients (11 men, 14 women, mean ages: 52.5 years) who had solitary pulmonary nodules, which we could not discriminate as being benign or malignant on the CT findings. All the subjects had CT-guided percutaenous cutting needle biopsy (PCNB) performed on them at our institution. A definitive diagnosis of benignity or malignancy was established to retrospectively analyze the patient's records. We evaluated the accuracy, sensitivity, specificity and complications of PCNB for the definitive diagnosis of benignity or malignancy. The sensitivity and specificity of PCNB were determined using the Chi-square test, and the correlations with pneumothorax and emphysema after biopsy were analyzed using Spearman's rank correlation coefficient. In two nodules of the twenty-five nodules, no definitive diagnosis could be established. Of the remaining twenty-three nodules, 7 (30.4%) were malignant and 16 (69.6%) were benign. Twenty (87%) of the twenty-three definitively diagnosed nodules were correctly diagnosed with PCNB. Of the twenty nodules, 6 (30%) were malignant and 14 (70%) were benign. The sensitivity and specificity of the malignant nodules were 85.7% (6/7) and 100% (16/16), respectively. The sensitivity and specificity of the benign nodules were 87.5% (14/16) and 85.7% (6/7), respectively. Post-biopsy complication occurred in nine patients (36%): Hemoptysis (n=4, 16%) and pneumothorax (n=5, 20%). However, there was not a statistical significance between pneumothorax and emphysema after biopsy (r=0.3, p=0.15). When CT-guided percutaneous lung biopsy of the solitary pulmonary nodules smaller than 15 mm in diameter was performed without an on-site cytopathologist, we know that PCNB can yield high diagnostic accuracy and very few complications

  16. Ultra-large bandwidth hollow-core guiding in all-silica bragg fibers with nano-supports

    DEFF Research Database (Denmark)

    Vienne, Guillaume; Xu, Yong; Jakobsen, Christian

    2004-01-01

    We demonstrate a new class of hollow-core Bragg fibers that are composed of concentric cylindrical silica rings separated by nanoscale support bridges. We theoretically predict and experimentally observe hollow-core confinement over an octave frequency range. The bandwidth of bandgap guiding in t...... in this new class of Bragg fibers exceeds that of other hollow-core fibers reported in the literature. With only three rings of silica cladding layers, these Bragg fibers achieve propagation loss of the order of 1 dB/m....

  17. Needle Decompression in Appalachia Do Obese Patients Need Longer Needles?

    Directory of Open Access Journals (Sweden)

    Carter, Thomas Edward

    2013-11-01

    Full Text Available Introduction: Needle decompression of a tension pneumothorax can be a lifesaving procedure. It requires an adequate needle length to reach the chest wall to rapidly remove air. With adult obesity exceeding one third of the United States population in 2010, we sought to evaluate the proper catheter length that may result in a successful needle decompression procedure. Advance Trauma Life Support (ATLS currently recommends a 51 millimeter (mm needle, while the needles stocked in our emergency department are 46 mm. Given the obesity rates of our patient population, we hypothesize these needles would not have a tolerable success rate of 90%. Methods: We retrospectively reviewed 91 patient records that had computed tomography of the chest and measured the chest wall depth at the second intercostal space bilaterally. Results: We found that 46 mm needles would only be successful in 52.7% of our patient population, yet the ATLS recommended length of 51 mm has a success rate of 64.8%. Therefore, using a 64 mm needle would be successful in 79% percent of our patient population. Conclusion: Use of longer length needles for needle thoracostomy is essential given the extent of the nation’s adult obesity population. [West J Emerg Med. 2013;14(6:650-652.

  18. Teleoperation of steerable flexible needles by combining kinesthetic and vibratory feedback.

    Science.gov (United States)

    Pacchierotti, Claudio; Abayazid, Momen; Misra, Sarthak; Prattichizzo, Domenico

    2014-01-01

    Needle insertion in soft-tissue is a minimally invasive surgical procedure that demands high accuracy. In this respect, robotic systems with autonomous control algorithms have been exploited as the main tool to achieve high accuracy and reliability. However, for reasons of safety and responsibility, autonomous robotic control is often not desirable. Therefore, it is necessary to focus also on techniques enabling clinicians to directly control the motion of the surgical tools. In this work, we address that challenge and present a novel teleoperated robotic system able to steer flexible needles. The proposed system tracks the position of the needle using an ultrasound imaging system and computes needle's ideal position and orientation to reach a given target. The master haptic interface then provides the clinician with mixed kinesthetic-vibratory navigation cues to guide the needle toward the computed ideal position and orientation. Twenty participants carried out an experiment of teleoperated needle insertion into a soft-tissue phantom, considering four different experimental conditions. Participants were provided with either mixed kinesthetic-vibratory feedback or mixed kinesthetic-visual feedback. Moreover, we considered two different ways of computing ideal position and orientation of the needle: with or without set-points. Vibratory feedback was found more effective than visual feedback in conveying navigation cues, with a mean targeting error of 0.72 mm when using set-points, and of 1.10 mm without set-points.

  19. Metastatic renal cell carcinoma in the thyroid gland: ultrasonographic features and the diagnostic role of core needle biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Song, Ok Kyu; Koo, Ja Seung; Kwak, Jin Young; Moon, Hee Jung; Yoon, Jung Hyun; Kim, Eun Kyung [Severance Hospital, Yonsei University College of Medicine, Seoul(Korea, Republic of)

    2017-07-15

    The aims of this study were to present the ultrasonographic (US) features of metastatic renal cell carcinoma (RCC) in the thyroid gland and to evaluate the diagnostic utility of fine needle aspiration (FNA) and core needle biopsy (CNB). Eight patients with nine metastatic RCC nodules in the thyroid glands who were treated from January 2002 to March 2015 in a single tertiary hospital were consecutively selected and retrospectively reviewed. US features and clinical history were obtained from the institution’s medical database. FNA was performed nine times on eight nodules and CNB was performed six times on six nodules. The diagnostic utility of FNA and CNB was evaluated. All nine nodules showed mass formation without diffuse thyroid involvement. On ultrasonography, metastatic RCC nodules were solid (100%), hypoechoic (100%), and ovalshaped nodules with a well-defined smooth margin (88.9%) and increased vascularity (100%, with 55% showing extensive vascularity). No calcifications were noted in any nodules. Lymph node metastasis and direct extension to nearby structures beyond the thyroid gland were not found. One FNA (11%) was able to confirm metastatic RCC, whereas all six CNBs confirmed metastatic RCC. Metastatic RCC appears as oval-shaped hypoechoic solid nodules with well-defined smooth margins, no calcifications, and increased vascularity on ultrasonography. Characteristic US features along with a previous history of RCC should raise clinical suspicion, and CNB should be performed to make an accurate diagnosis.

  20. Driven Around the Bend: Novel Use of a Curved Steerable Needle

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, Darra T., E-mail: darra.murphy@vch.ca; Korzan, Jeffrey R.; Ouellette, Hugue A.; Liu, David M. [Vancouver General Hospital, Department of Radiology (Canada); Clarkson, Paul W. [Vancouver General Hospital, Department of Orthopedic Surgery (Canada); Munk, Peter L. [Vancouver General Hospital, Department of Radiology (Canada)

    2013-04-15

    This technical note describes the novel use of a curved, steerable needle to access symptomatic osseous lesions in the pelvis and sacrum for palliative percutaneous treatment that would otherwise be difficult to treat using conventional straight needles. Seven patients with lytic bone lesions were treated. One patient had multiple myeloma; the remaining had metastatic disease: breast carcinoma (n = 2), colorectal carcinoma (n = 1), renal cell carcinoma (n = 1), squamous cell carcinoma (n = 1), and leiomyosarcoma (n = 1). Five of the seven patients had lesions in the posterior acetabulum, and the two other patients had lesions in the sacrum. Four of the seven patients received radiofrequency ablation followed by cementoplasty; three patients received cementation alone. We used a novel needle designed for vertebroplasty, which has an articulating tip allowing it to be guided into lytic bone lesions located in difficult-to-access regions of the pelvis and sacrum. All patients were successfully treated with cementoplasty either with or without thermal ablation. No serious adverse events were reported. The needle was difficult to withdraw in two patients. Steerable curved needles can be successfully used to treat lytic osseous metastases with cementoplasty when lesions are located in sites that may be difficult to reach using conventional straight needles.

  1. Computed tomography-guided percutaneous biopsy of pancreatic masses using pneumodissection; Biopsia percutanea de massas pancreaticas guiada por tomografia computadorizada com pneumodisseccao

    Energy Technology Data Exchange (ETDEWEB)

    Tyng, Chiang Jeng; Bitencourt, Almir Galvao Vieira; Almeida, Maria Fernanda Arruda; Barbosa, Paula Nicole Vieira; Martins, Eduardo Bruno Lobato; Junior, Joao Paulo Kawaoka Matushita; Chojniak, Rubens, E-mail: chiangjengtyng@gmail.com [Hospital A.C. Camargo, Sao Paulo, SP (Brazil). Dept. de Imagem; Coimbra, Felipe Jose Fernandez [Hospital A.C. Camargo, Sao Paulo, SP (Brazil). Dept. de Cirurgia Abdominal

    2013-05-15

    Objective: to describe the technique of computed tomography-guided percutaneous biopsy of pancreatic tumors with pneumodissection. Materials and methods: in the period from June 2011 to May 2012, seven computed tomography guided percutaneous biopsies of pancreatic tumors utilizing pneumodissection were performed in the authors' institution. All the procedures were performed with an automatic biopsy gun and coaxial system with Tru-core needles. The biopsy specimens were histologically assessed. Results: in all the cases the pancreatic mass could not be directly approached by computed tomography without passing through major organs and structures. The injection of air allowed the displacement of adjacent structures and creation of a safe coaxial needle pathway toward the lesion. Biopsy was successfully performed in all the cases, yielding appropriate specimens for pathological analysis. Conclusion: Pneumodissection is a safe, inexpensive and technically easy approach to perform percutaneous biopsy in selected cases where direct access to the pancreatic tumor is not feasible. (author)

  2. Endobronchial ultrasound-guided transbronchial needle aspiration is a sensitive method to evaluate patients who should not undergo pulmonary metastasectomy†

    DEFF Research Database (Denmark)

    Eckardt, Jens; Licht, Peter Bjørn

    2015-01-01

    metastasectomy with systematic sampling of mediastinal lymph nodes for histological evaluation. RESULTS: One hundred and three eligible patients were referred for EBUS-TBNA during a 4-year period. The primary cancers were located in the colon/rectum (n = 64), kidney (n = 16) and other sites (n = 23). EBUS......OBJECTIVES: Pulmonary metastasectomy is considered an effective treatment in selected patients with extrapulmonary cancer and oligometastatic disease. We know that the presence of mediastinal lymph node metastases reduces survival significantly, but the mediastinum is rarely evaluated before...... metastasectomy in these patients. We prospectively evaluated how endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) could identify metastases to the mediastinal lymph nodes in patients referred for pulmonary metastasectomy. METHODS: All patients with extrapulmonary cancer...

  3. Does a paresthesia during spinal needle insertion indicate intrathecal needle placement?

    Science.gov (United States)

    Pong, Ryan P; Gmelch, Benjamin S; Bernards, Christopher M

    2009-01-01

    Paresthesias are relatively common during spinal needle insertion, however, the clinical significance of the paresthesia is unknown. A paresthesia may result from needle-to-nerve contact with a spinal nerve in the epidural space, or, with far lateral needle placement, may result from contact with a spinal nerve within the intervertebral foramen. However, it is also possible and perhaps more likely, that paresthesias occur when the spinal needle contacts a spinal nerve root within the subarachnoid space. This study was designed to test this latter hypothesis. Patients (n = 104) scheduled for surgery under spinal anesthesia were observed during spinal needle insertion. If a paresthesia occurred, the needle was fixed in place and the stylet removed to observe whether cerebrospinal fluid (CSF) flowed from the hub. The presence of CSF was considered proof that the needle had entered the subarachnoid space. Paresthesias occurred in 14/103 (13.6%) of patients; 1 patient experienced a paresthesia twice. All paresthesias were transient. Following a paresthesia, CSF was observed in the needle hub 86.7% (13/15) of the time. Our data suggest that the majority of transient paresthesias occur when the spinal needle enters the subarachnoid space and contacts a spinal nerve root. Therefore, when transient paresthesias occur during spinal needle placement it is appropriate to stop and assess for the presence of CSF in the needle hub, rather than withdraw and redirect the spinal needle away from the side of the paresthesia as some authors have suggested.

  4. Image guided percutaneous splenic interventions

    International Nuclear Information System (INIS)

    Kang, Mandeep; Kalra, Naveen; Gulati, Madhu; Lal, Anupam; Kochhar, Rohit; Rajwanshi, Arvind

    2007-01-01

    Aim: The objective of this study is to evaluate the efficacy and safety of image-guided percutaneous splenic interventions as diagnostic or therapeutic procedures. Materials and methods: We performed a retrospective review of our interventional records from July 2001 to June 2006. Ninety-five image-guided percutaneous splenic interventions were performed after informed consent in 89 patients: 64 men and 25 women who ranged in age from 5 months to 71 years (mean, 38.4 years) under ultrasound (n = 93) or CT (n = 2) guidance. The procedures performed were fine needle aspiration biopsy of focal splenic lesions (n = 78) and aspiration (n = 10) or percutaneous catheter drainage of a splenic abscess (n = 7). Results: Splenic fine needle aspiration biopsy was successful in 62 (83.78%) of 74 patients with benign lesions diagnosed in 43 (58.1%) and malignancy in 19 (25.67%) patients. The most common pathologies included tuberculosis (26 patients, 35.13%) and lymphoma (14 patients, 18.91%). Therapeutic aspiration or pigtail catheter drainage was successful in all (100%) patients. There were no major complications. Conclusions: Image-guided splenic fine needle aspiration biopsy is a safe and accurate technique that can provide a definitive diagnosis in most patients with focal lesions in the spleen. This study also suggests that image-guided percutaneous aspiration or catheter drainage of splenic abscesses is a safe and effective alternative to surgery

  5. Risks and benefits in treatment of mediastinal abscess by endobronchial ultrasound-guided transbronchial needle aspiration.

    Science.gov (United States)

    Tian, Lei; Krimsky, William S; Wu, Qingchen; Sun, Jiayuan

    2017-07-01

    Mediastinal abscess is a fatal condition, treatment of mediastinal abscess is with antibiotics and sometimes surgery for debridement and drainage. Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a safe assessment and candidate treatment method of mediastinal lesions. This study aimed to HYPERLINK "javascript:void(0);" discuss risks and benefits in treatment of mediastinal abscess by EBUS-TBNA. We noticed a 56-year-old man with developed bilateral pneumonia and sepsis after puncture of mediastinal abscess by EBUS-TBNA. The patient was successfully treated with a combination of systemic anti-infection treatment and intracavitary administration of antibiotics, antifungal and repeated drainage and lavage via EBUS-TBNA, in 1 year follow-up without recurrence. This study indicated infection spread risk of mediastinal abscess after EBUS-TBNA, and mediastinal abscess was successfully cured by combination of systemic anti-infection and local intervention through EBUS-TBNA. EBUS-TBNA is a potential effective minimally invasive treatment for mediastinal abscess, and it is necessary to be aware of clinical complications after puncture of mediastinal infectious lesions by EBUS-TBNA. © 2015 John Wiley & Sons Ltd.

  6. Endobronchial Ultrasound Guided Transbronchial Needle Aspiration (ebus-tbna) for Diagnosis of Mediastinal and Hilar Masses

    International Nuclear Information System (INIS)

    Fatima, M.; Jamal, S.; Khan, M.A.; Ansari, J.K.; Ullah, M.U.

    2016-01-01

    Objective: To determine the sensitivity, specificity, negative and positive predictive values, and diagnostic accuracy of Endobronchial Ultrasound Guided Transbronchial Needle Aspiration (EBUS-TBNA). Study Design: Across-sectional validation study. Place and Duration of Study: Department of Histopathology, Army Medical College, in collaboration with Department of Pulmonology, Military Hospital Rawalpindi, from March 2014 to March 2015. Methodology: Cases of EBUS-TBNAcomprised of both TBNAs and cell block/biopsy of the same patients. Diagnosis was made on the TBNAslides and cell block/biopsy material. Taking biopsy/cell block as the gold standard, the data was analysed to calculate the sensitivity, specificity, negative and positive predictive values, and diagnostic accuracy of EBUSTBNA. Result: The sensitivity of EBUS-TBNAwas found to be 96.5 percent; whereas, specificity and positive predictive values were 100 percent. The negative predictive value was calculated at 50 percent. Diagnostic accuracy of the procedure was found to be 96.67 percent. Conclusion: EBUS-TBNA is a sensitive and a specific test and is accurate in diagnosing mediastinal and hilar pathologies. (author)

  7. Diagnosis of prostate cancer with needle biopsy: Should all cases ...

    African Journals Online (AJOL)

    Background: The triad of digital rectal examination (DRE), serum prostate specific antigen, and transrectal ultrasound‑guided prostate biopsy is used in the detection of prostate cancer (PCa). It is recommended that all cases of PCa should be diagnosed with needle biopsy before treatment. The exclusion criteria for those ...

  8. Ultrasound-guided forceps for pleural biopsy

    Directory of Open Access Journals (Sweden)

    Gamal Agmy

    2014-04-01

    Clinical implications: Ultrasound-guided forceps for pleural biopsy can overcome many of the limitations of the conventional needle biopsy procedures, provides multiple biopsy specimens of the parietal pleura that are inaccessible to the biopsy needle, and can be carried out easily and safely even in sick and obese patients. The diagnostic yield is nearly similar to thoracoscopy.

  9. TU-H-CAMPUS-JeP3-05: Adaptive Determination of Needle Sequence HDR Prostate Brachytherapy with Divergent Needle-By-Needle Delivery

    International Nuclear Information System (INIS)

    Borot de Battisti, M; Maenhout, M; Lagendijk, J J W; Van Vulpen, M; Moerland, M A; Denis de Senneville, B; Hautvast, G; Binnekamp, D

    2016-01-01

    Purpose: To develop a new method which adaptively determines the optimal needle insertion sequence for HDR prostate brachytherapy involving divergent needle-by-needle dose delivery by e.g. a robotic device. A needle insertion sequence is calculated at the beginning of the intervention and updated after each needle insertion with feedback on needle positioning errors. Methods: Needle positioning errors and anatomy changes may occur during HDR brachytherapy which can lead to errors in the delivered dose. A novel strategy was developed to calculate and update the needle sequence and the dose plan after each needle insertion with feedback on needle positioning errors. The dose plan optimization was performed by numerical simulations. The proposed needle sequence determination optimizes the final dose distribution based on the dose coverage impact of each needle. This impact is predicted stochastically by needle insertion simulations. HDR procedures were simulated with varying number of needle insertions (4 to 12) using 11 patient MR data-sets with PTV, prostate, urethra, bladder and rectum delineated. Needle positioning errors were modeled by random normally distributed angulation errors (standard deviation of 3 mm at the needle’s tip). The final dose parameters were compared in the situations where the needle with the largest vs. the smallest dose coverage impact was selected at each insertion. Results: Over all scenarios, the percentage of clinically acceptable final dose distribution improved when the needle selected had the largest dose coverage impact (91%) compared to the smallest (88%). The differences were larger for few (4 to 6) needle insertions (maximum difference scenario: 79% vs. 60%). The computation time of the needle sequence optimization was below 60s. Conclusion: A new adaptive needle sequence determination for HDR prostate brachytherapy was developed. Coupled to adaptive planning, the selection of the needle with the largest dose coverage impact

  10. Significant Histological Features Differentiating Cellular Fibroadenoma from Phyllodes Tumor on Core Needle Biopsies

    Science.gov (United States)

    Yasir, Saba; Gamez, Roberto; Jenkins, Sarah; Visscher, Daniel W.; Nassar, Aziza

    2015-01-01

    Objectives Cellular fibroepithelial lesions (CFEL) are a heterogeneous group of tumors encompassing cellular fibroadenoma (CFA) and phyllodes tumor (PT). Distinction between the two is challenging on core needle biopsy (CNB). The objective of this study was to evaluate histological features that can help distinguish PT from CFA on CNB. Methods Records of all patients diagnosed with CFEL on CNB with follow-up excision between 2002 and 2012 were retrieved. Histopathological stromal features were evaluated on CNB including mitoses per 10 HPF, overgrowth, increased cellularity, fragmentation, adipose tissue infiltration, heterogeneity, subepithelial condensation, and nuclear pleomorphism. Results Twenty-seven of 64 (42.2%) were diagnosed as PT (24 BPT, 3 borderline PT) and 37 (57.8%) as CFA on excision. All features except for increased stromal cellularity were statistically significant. The average number of histologic features seen in PT and CFA was 3.9 and 1.4, respectively (OR 7.27; 95% CI: 2.44, 21.69; p= 0.0004). The average mitoses per 10 HPF was 3.0 for PT as compared to 0.8 for CFA (OR 2.14; 95% CI: 1.18, 3.86; p= 0.01). Conclusions The presence of mitosis (3 or more) and/or total histologic features of 3 or more on CNB were most helpful features in predicting PT on excision. PMID:25125627

  11. Transthoracic needle biopsy: factors effecting risk of pneumothorax

    International Nuclear Information System (INIS)

    Topal, Ugur; Ediz, Buelent

    2003-01-01

    Objective: to evaluate the factors that could effect the risk of pneumothorax in patients undergoing transthoracic biopsy. Material and methods: variables that could increase the risk of pneumothorax were evaluated in 453 CT-guided transthoracic biopsies. Factors were evaluated in two groups: (1) lesion related (presence of emphysema around the lesion, lesion depth, cavitation, presence of fissure/atelectasis and pleural tag in the needle trajectory); and (2) procedure related (biopsy type, needle size, number of passages, level of experience of the operator). All variables were analysed by χ 2 test and multivariate logistic regression statistics. Results: pneumothorax was developed in 85 (18.8%) out of 453 procedures. A chest tube was inserted in ten (11.7%) of them. Variables that were significantly associated with an increased risk of pneumothorax were depth of the lesion (P<0.001) and severity of the emphysema (P<0.01). Conclusion: the length of the lung parenchyma traversed during the biopsy is the predominant risk factor for pneumothorax in patients undergoing CT-guided transthoracic biopsy. The risk of pneumothorax was also increased with the severity of the emphysema around the lesion

  12. Pneumatically Operated MRI-Compatible Needle Placement Robot for Prostate Interventions.

    Science.gov (United States)

    Fischer, Gregory S; Iordachita, Iulian; Csoma, Csaba; Tokuda, Junichi; Mewes, Philip W; Tempany, Clare M; Hata, Nobuhiko; Fichtinger, Gabor

    2008-06-13

    Magnetic Resonance Imaging (MRI) has potential to be a superior medical imaging modality for guiding and monitoring prostatic interventions. The strong magnetic field prevents the use of conventional mechatronics and the confined physical space makes it extremely challenging to access the patient. We have designed a robotic assistant system that overcomes these difficulties and promises safe and reliable intra-prostatic needle placement inside closed high-field MRI scanners. The robot performs needle insertion under real-time 3T MR image guidance; workspace requirements, MR compatibility, and workflow have been evaluated on phantoms. The paper explains the robot mechanism and controller design and presents results of preliminary evaluation of the system.

  13. Measurement of bio-impedance with a smart needle to confirm percutaneous kidney access.

    Science.gov (United States)

    Hernandez, D J; Sinkov, V A; Roberts, W W; Allaf, M E; Patriciu, A; Jarrett, T W; Kavoussi, L R; Stoianovici, D

    2001-10-01

    The traditional method of percutaneous renal access requires freehand needle placement guided by C-arm fluoroscopy, ultrasonography, or computerized tomography. This approach provides limited objective means for verifying successful access. We developed an impedance based percutaneous Smart Needle system and successfully used it to confirm collecting system access in ex vivo porcine kidneys. The Smart Needle consists of a modified 18 gauge percutaneous access needle with the inner stylet electrically insulated from the outer sheath. Impedance is measured between the exposed stylet tip and sheath using Model 4275 LCR meter (Hewlett-Packard, Sunnyvale, California). An ex vivo porcine kidney was distended by continuous gravity infusion of 100 cm. water saline from a catheter passed through the parenchyma into the collecting system. The Smart Needle was gradually inserted into the kidney to measure depth precisely using a robotic needle placement system, while impedance was measured continuously. The Smart Needle was inserted 4 times in each of 4 kidneys. When the needle penetrated the distended collecting system in 11 of 16 attempts, a characteristic sharp drop in resistivity was noted from 1.9 to 1.1 ohm m. Entry into the collecting system was confirmed by removing the stylet and observing fluid flow from the sheath. This characteristic impedance change was observed only at successful entry into the collecting system. A characteristic sharp drop in impedance signifies successful entry into the collecting system. The Smart Needle system may prove useful for percutaneous kidney access.

  14. EUS Needle Identification Comparison and Evaluation study (with videos)

    DEFF Research Database (Denmark)

    Tang, Shou-Jiang; Vilmann, Andreas S; Saftoiu, Adrian

    2016-01-01

    Control (Medi-Globe); Expect Slimline (Boston Scientific); EchoTip, EchoTip Ultra, EchoTip ProCore High Definition (Cook Medical); ClearView (Conmed); EZ Shot 2 (Olympus); and BNX (Beacon Endoscopic), and 2 new prototype needles, SonoCoat (Medi-Globe), coated by echogenic polymers made by Encapson...

  15. Ultrasound-guided core biopsy: an effective method of detecting axillary nodal metastases.

    LENUS (Irish Health Repository)

    Solon, Jacqueline G

    2012-02-01

    BACKGROUND: Axillary nodal status is an important prognostic predictor in patients with breast cancer. This study evaluated the sensitivity and specificity of ultrasound-guided core biopsy (Ax US-CB) at detecting axillary nodal metastases in patients with primary breast cancer, thereby determining how often sentinel lymph node biopsy could be avoided in node positive patients. STUDY DESIGN: Records of patients presenting to a breast unit between January 2007 and June 2010 were reviewed retrospectively. Patients who underwent axillary ultrasonography with or without preoperative core biopsy were identified. Sensitivity, specificity, positive predictive value, and negative predictive value for ultrasonography and percutaneous biopsy were evaluated. RESULTS: Records of 718 patients were reviewed, with 445 fulfilling inclusion criteria. Forty-seven percent (n = 210\\/445) had nodal metastases, with 110 detected by Ax US-CB (sensitivity 52.4%, specificity 100%, positive predictive value 100%, negative predictive value 70.1%). Axillary ultrasonography without biopsy had sensitivity and specificity of 54.3% and 97%, respectively. Lymphovascular invasion was an independent predictor of nodal metastases (sensitivity 60.8%, specificity 80%). Ultrasound-guided core biopsy detected more than half of all nodal metastases, sparing more than one-quarter of all breast cancer patients an unnecessary sentinel lymph node biopsy. CONCLUSIONS: Axillary ultrasonography, when combined with core biopsy, is a valuable component of the management of patients with primary breast cancer. Its ability to definitively identify nodal metastases before surgical intervention can greatly facilitate a patient\\'s preoperative integrated treatment plan. In this regard, we believe our study adds considerably to the increasing data, which indicate the benefit of Ax US-CB in the preoperative detection of nodal metastases.

  16. Teleoperation System with Hybrid Pneumatic-Piezoelectric Actuation for MRI-Guided Needle Insertion with Haptic Feedback

    OpenAIRE

    Shang, Weijian; Su, Hao; Li, Gang; Fischer, Gregory S.

    2013-01-01

    This paper presents a surgical master-slave tele-operation system for percutaneous interventional procedures under continuous magnetic resonance imaging (MRI) guidance. This system consists of a piezoelectrically actuated slave robot for needle placement with integrated fiber optic force sensor utilizing Fabry-Perot interferometry (FPI) sensing principle. The sensor flexure is optimized and embedded to the slave robot for measuring needle insertion force. A novel, compact opto-mechanical FPI ...

  17. A compact mechatronic system for 3D ultrasound guided prostate interventions

    International Nuclear Information System (INIS)

    Bax, Jeffrey; Smith, David; Bartha, Laura; Montreuil, Jacques; Sherebrin, Shi; Gardi, Lori; Edirisinghe, Chandima; Fenster, Aaron

    2011-01-01

    Purpose: Ultrasound imaging has improved the treatment of prostate cancer by producing increasingly higher quality images and influencing sophisticated targeting procedures for the insertion of radioactive seeds during brachytherapy. However, it is critical that the needles be placed accurately within the prostate to deliver the therapy to the planned location and avoid complications of damaging surrounding tissues. Methods: The authors have developed a compact mechatronic system, as well as an effective method for guiding and controlling the insertion of transperineal needles into the prostate. This system has been designed to allow guidance of a needle obliquely in 3D space into the prostate, thereby reducing pubic arch interference. The choice of needle trajectory and location in the prostate can be adjusted manually or with computer control. Results: To validate the system, a series of experiments were performed on phantoms. The 3D scan of the string phantom produced minimal geometric error, which was less than 0.4 mm. Needle guidance accuracy tests in agar prostate phantoms showed that the mean error of bead placement was less then 1.6 mm along parallel needle paths that were within 1.2 mm of the intended target and 1 deg. from the preplanned trajectory. At oblique angles of up to 15 deg. relative to the probe axis, beads were placed to within 3.0 mm along a trajectory that were within 2.0 mm of the target with an angular error less than 2 deg. Conclusions: By combining 3D TRUS imaging system to a needle tracking linkage, this system should improve the physician's ability to target and accurately guide a needle to selected targets without the need for the computer to directly manipulate and insert the needle. This would be beneficial as the physician has complete control of the system and can safely maneuver the needle guide around obstacles such as previously placed needles.

  18. Experimental observation of spontaneous depolarized guided acoustic-wave Brillouin scattering in side cores of a multicore fiber

    Science.gov (United States)

    Hayashi, Neisei; Mizuno, Yosuke; Nakamura, Kentaro; Set, Sze Yun; Yamashita, Shinji

    2018-06-01

    Spontaneous depolarized guided acoustic-wave Brillouin scattering (GAWBS) was experimentally observed in one of the side cores of an uncoated multicore fiber (MCF). The frequency bandwidth in the side core was up to ∼400 MHz, which is 0.5 times that in the central core. The GAWBS spectrum of the side core of the MCF included intrinsic peaks, which had different acoustic resonance frequencies from those of the central core. In addition, the spontaneous depolarized GAWBS in the central/side core was unaffected by that in the other core. These results will lead to the development of polarization/phase modulators using an MCF.

  19. Experience of CT Guided Procedures in the Diagnosis of 55 patients ...

    African Journals Online (AJOL)

    All fine needle aspirations were performed with 20-gauge needles while core tissue biopsies were performed with 14 –gauge needles under CT guidance. The diagnostic yield of these procedures, complications, and patient's feedback were studied. Results: Diagnosis was malignant lesions in 18(32.1%), benign in ...

  20. [Fine needle aspiration cytology of mammography screening

    DEFF Research Database (Denmark)

    Engvad, B.; Laenkholm, A.V.; Schwartz, Thue W.

    2009-01-01

    INTRODUCTION: In the year 2000 a quality assurance programme for the preoperative breast diagnostics was introduced in Denmark. The programme was based on the "European guidelines for quality assurance in breast cancer screening and diagnosis" where - among other measures - five cytological...... diagnostic classes were introduced. The aim of this study was to evaluate the quality assurance programme in a screening population to determine whether fine needle aspiration cytology (FNAC) as first choice remains a useful tool in the preoperative diagnostics, or if needle core biopsy should be the first...... of 66% of the 783 FNACs had a malignant cytology diagnosis, which in 99% of the cases turned out to be the correct diagnosis. Four lesions were false positives all of which represented benign proliferative breast diseases. The surgical procedures in these cases were either excisional biopsy...

  1. Ultrasound-guided percutaneous biopsy of digestive tract lesions

    International Nuclear Information System (INIS)

    Gil, S.; Martin, I.; Ballesteros, J. M.; Gomez, C.; Marco, S. F.; Fernandez, P.

    1999-01-01

    To present our experience in ultrasound-guided percutaneous biopsy of lesions located in the digestive tract. We performed ultrasound-guided percutaneous biopsy in 14 patients (10 men and 4 women) ranging in age from 7 to 71 years (mean; 519 years). The lesions were located throughout the digestive tract, from the pyriform sinus to the sigmoid colon. The biopsy was carried out with a 5 MHz convex probe equipped with a device to direct the needle. An 18G automatic needle or a 20G Chiba needle was used to obtain specimens for histological study in every case, and additional samples were collected with a 22G needle for cytological examination in 13 of the patients. The ultrasound images corresponded to pseudokidney in 9 cases and extrinsic masses in 5. The diagnosis was obtained from the histological examination in every case (100%) and from cytology in 6 (44.4%), the latter results were less specific. The only complication corresponded to a case of bilioperitoneum. Ultrasound-guided percutaneous biopsy is a suitable technique for the histological diagnosis of those lesions of the digestive tract that are visible in ultrasound images, but that for some reason can not be examined by endoscopic biopsy. (Author) 20 refs

  2. MR-guided MR arthrography of the shoulder

    International Nuclear Information System (INIS)

    Tratting, S.; Breitenseher, M.; Pretterklieber, M.; Kontaxis, G.; Rand, T.; Imhof, H.

    1996-01-01

    Purpose: To develop an MR-guided technique for joint puncture in MR arthrography of the shoulder and to confirm the intracapsular position of the needle tip by visualization of the flow of contrast media into the joint. Materials and methods: Three unfixed human shoulder joint specimens were examined on a 1.0 T unit. The optimal point of entrance and depth for joint puncture were estimated by means of MR-compatible markers on the skin. Needle orientation and localization of the needle tip (MR-compatible 22-gauge needle) in the shoulder joint were monitored by rapid localizer gradient-echo sequences in two orthogonal planes. To confirm the intracapsular position of the needle tip, diluted gadolinium-DTPA was administered via a long connecting tube and the flow of contrast media into the joint was viewed directly on an LCD screen using real-time MR imaging (local look technique). Results: The MR-compatible markers on the skin allowed determination of the optimal point of entrance and estimation of the depth for joint puncture. Passive visualization of the MR-compatible needle due to spin dephasing and signal loss provided adequate localization of the intra-articular needle tip position in all specimens, although significant artefacts were present on rapid localizer gradient-echo sequences with an increase in width of the apparent needle shaft. Real-time MR imaging of the flow of contrast media was possible using the local look technique and the LCD screen of the MR unit and allowed confirmation of the intracapsular position. Conclusion: MR-guided joint puncture and real-time MR-assisted contrast media application results in improved MR arthrography and may replace conventional fluoroscopic guidance. (orig.) [de

  3. Teleoperation System with Hybrid Pneumatic-Piezoelectric Actuation for MRI-Guided Needle Insertion with Haptic Feedback.

    Science.gov (United States)

    Shang, Weijian; Su, Hao; Li, Gang; Fischer, Gregory S

    2013-01-01

    This paper presents a surgical master-slave tele-operation system for percutaneous interventional procedures under continuous magnetic resonance imaging (MRI) guidance. This system consists of a piezoelectrically actuated slave robot for needle placement with integrated fiber optic force sensor utilizing Fabry-Perot interferometry (FPI) sensing principle. The sensor flexure is optimized and embedded to the slave robot for measuring needle insertion force. A novel, compact opto-mechanical FPI sensor interface is integrated into an MRI robot control system. By leveraging the complementary features of pneumatic and piezoelectric actuation, a pneumatically actuated haptic master robot is also developed to render force associated with needle placement interventions to the clinician. An aluminum load cell is implemented and calibrated to close the impedance control loop of the master robot. A force-position control algorithm is developed to control the hybrid actuated system. Teleoperated needle insertion is demonstrated under live MR imaging, where the slave robot resides in the scanner bore and the user manipulates the master beside the patient outside the bore. Force and position tracking results of the master-slave robot are demonstrated to validate the tracking performance of the integrated system. It has a position tracking error of 0.318mm and sine wave force tracking error of 2.227N.

  4. Teleoperation System with Hybrid Pneumatic-Piezoelectric Actuation for MRI-Guided Needle Insertion with Haptic Feedback

    Science.gov (United States)

    Shang, Weijian; Su, Hao; Li, Gang; Fischer, Gregory S.

    2014-01-01

    This paper presents a surgical master-slave tele-operation system for percutaneous interventional procedures under continuous magnetic resonance imaging (MRI) guidance. This system consists of a piezoelectrically actuated slave robot for needle placement with integrated fiber optic force sensor utilizing Fabry-Perot interferometry (FPI) sensing principle. The sensor flexure is optimized and embedded to the slave robot for measuring needle insertion force. A novel, compact opto-mechanical FPI sensor interface is integrated into an MRI robot control system. By leveraging the complementary features of pneumatic and piezoelectric actuation, a pneumatically actuated haptic master robot is also developed to render force associated with needle placement interventions to the clinician. An aluminum load cell is implemented and calibrated to close the impedance control loop of the master robot. A force-position control algorithm is developed to control the hybrid actuated system. Teleoperated needle insertion is demonstrated under live MR imaging, where the slave robot resides in the scanner bore and the user manipulates the master beside the patient outside the bore. Force and position tracking results of the master-slave robot are demonstrated to validate the tracking performance of the integrated system. It has a position tracking error of 0.318mm and sine wave force tracking error of 2.227N. PMID:25126446

  5. Successful treatment of athletic pubalgia in a lacrosse player with ultrasound-guided needle tenotomy and platelet-rich plasma injection: a case report.

    Science.gov (United States)

    Scholten, Paul M; Massimi, Stephen; Dahmen, Nick; Diamond, Joanne; Wyss, James

    2015-01-01

    Athletic pubalgia is a syndrome of persistent groin pain due to chronic repetitive trauma or stress involving the pelvic joints and many musculotendinous structures that cross the anterior pelvis. As a result, the differential diagnosis can be complex, but insertional tendinopathies are the most common. This case report describes a novel approach to the treatment of distal rectus abdominis tendinopathies with ultrasound-guided needle tenotomy and platelet-rich plasma (PRP) injection. After injection, the patient returned to pain-free play at his previous level of intensity. This suggests that PRP may be a useful treatment for this diagnosis. Copyright © 2015. Published by Elsevier Inc.

  6. Core biopsy as a simple and effective diagnostic tool in head and neck focal myositis.

    Science.gov (United States)

    Tan, Chun Yee; Chong, Sheldon; Shaw, Chi-Kee Leslie

    2015-12-01

    Most unilateral head and neck masses are benign, although malignancy is a possibility in some cases. However, there are other rare causes of unilateral neck masses, such as focal myositis, which is a rare, benign condition belonging to the family of inflammatory pseudotumors of the skeletal muscles, with rare presentations in the head and neck region. Focal myositis presents as a rapidly enlarging neck mass that can be misdiagnosed by fine-needle aspiration biopsy and/or radiologic imaging as either an infective or a neoplastic process. To date, there are only 5 reported cases of adult focal myositis of the sternocleidomastoid muscle in the medical literature. In this article, the authors present 2 cases involving patients with focal myositis of the sternocleidomastoid muscle that were successfully diagnosed with core-needle biopsy and managed conservatively. The pros and cons of fine-needle aspiration biopsy and core-needle biopsy are discussed. Based on the authors' results, fine-needle aspiration biopsy universally fails to provide the diagnosis of focal myositis. In contrast, core-needle biopsy successfully diagnosed focal myositis in both of our patients. Both of them had complete resolution with conservative management.

  7. Geographical and climatic limits of needle types of one- and two-needled pinyon pines

    Science.gov (United States)

    Cole, K.L.; Fisher, J.; Arundel, S.T.; Cannella, J.; Swift, S.

    2008-01-01

    Aim: The geographical extent and climatic tolerances of one- and two-needled pinyon pines (Pinus subsect. Cembroides) are the focus of questions in taxonomy, palaeoclimatology and modelling of future distributions. The identification of these pines, traditionally classified by one- versus two-needled fascicles, is complicated by populations with both one- and two-needled fascicles on the same tree, and the description of two more recently described one-needled varieties: the fallax-type and californiarum-type. Because previous studies have suggested correlations between needle anatomy and climate, including anatomical plasticity reflecting annual precipitation, we approached this study at the level of the anatomy of individual pine needles rather than species. Location: Western North America. Methods: We synthesized available and new data from field and herbarium collections of needles to compile maps of their current distributions across western North America. Annual frequencies of needle types were compared with local precipitation histories for some stands. Historical North American climates were modelled on a c. 1-km grid using monthly temperature and precipitation values. A geospatial model (ClimLim), which analyses the effect of climate-modulated physiological and ecosystem processes, was used to rank the importance of seasonal climate variables in limiting the distributions of anatomical needle types. Results: The pinyon needles were classified into four distinct types based upon the number of needles per fascicle, needle thickness and the number of stomatal rows and resin canals. The individual needles fit well into four categories of needle types, whereas some trees exhibit a mixture of two needle types. Trees from central Arizona containing a mixture of Pinus edulis and fallax-type needles increased their percentage of fallax-type needles following dry years. All four needle types occupy broader geographical regions with distinctive precipitation regimes

  8. A study to evaluate the efficacy of image-guided core biopsy in the diagnosis and management of lymphoma-Results in 103 biopsies

    International Nuclear Information System (INIS)

    Vandervelde, C.; Kamani, T.; Varghese, A.; Ramesar, K.; Grace, R.; Howlett, D.C.

    2008-01-01

    The reason for this study was to evaluate the ability of image-guided core biopsy to replace surgical excision by providing sufficient diagnostic and treatment information. All consecutive image-guided core biopsies in patients with a final diagnosis of lymphoma over a 6-year period at our institution were collected retrospectively. Case notes and pathology reports were reviewed and the diagnostic techniques used were recorded. Pathology reports were graded according to their diagnostic completeness and their ability to provide treatment information. Out of a total of 328 instances of lymphoma, 103 image-guided core biopsies were performed in 96 patients. In 78% of these, the diagnostic information obtained from the biopsy provided a fully graded and subtyped diagnosis of lymphoma with sufficient information to initiate therapy. In the head and neck 67% of core biopsies were fully diagnostic for treatment purposes compared to 91% in the thorax, abdomen and pelvis. Image-guided core biopsy has a number of cost and safety advantages over surgical excision biopsy and in suitable cases it can obviate the need for surgery in cases of suspected lymphoma. This is especially relevant for elderly patients and those with poor performance status

  9. A study to evaluate the efficacy of image-guided core biopsy in the diagnosis and management of lymphoma-Results in 103 biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Vandervelde, C. [Department of Radiology, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: clivevandervelde@gmail.com; Kamani, T. [Department of ENT Surgery, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: tkamany@yahoo.com; Varghese, A. [Department of Radiology, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: vargheseajay@hotmail.com; Ramesar, K. [Department of Histopathology, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: keith.ramesar@esht.nhs.uk; Grace, R. [Department of Haematology, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: richard.grace@esht.nhs.uk; Howlett, D.C. [Department of Radiology, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: david.howlett@esht.nhs.uk

    2008-04-15

    The reason for this study was to evaluate the ability of image-guided core biopsy to replace surgical excision by providing sufficient diagnostic and treatment information. All consecutive image-guided core biopsies in patients with a final diagnosis of lymphoma over a 6-year period at our institution were collected retrospectively. Case notes and pathology reports were reviewed and the diagnostic techniques used were recorded. Pathology reports were graded according to their diagnostic completeness and their ability to provide treatment information. Out of a total of 328 instances of lymphoma, 103 image-guided core biopsies were performed in 96 patients. In 78% of these, the diagnostic information obtained from the biopsy provided a fully graded and subtyped diagnosis of lymphoma with sufficient information to initiate therapy. In the head and neck 67% of core biopsies were fully diagnostic for treatment purposes compared to 91% in the thorax, abdomen and pelvis. Image-guided core biopsy has a number of cost and safety advantages over surgical excision biopsy and in suitable cases it can obviate the need for surgery in cases of suspected lymphoma. This is especially relevant for elderly patients and those with poor performance status.

  10. Stereotactic core biopsy: Comparison of 11 gauge with 8 gauge vacuum assisted breast biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Venkataraman, Shambhavi, E-mail: svenkata@bidmc.harvard.edu [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215 (United States); Dialani, Vandana [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215 (United States); Gilmore, Hannah L. [Department of Pathology, UH Case Medical Center, 11100 Euclid Ave, Cleveland, OH 44106 (United States); Mehta, Tejas S. [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215 (United States)

    2012-10-15

    Purpose: The compare the performance and ability to obtain a correct diagnosis on needle biopsy between 11 gauge and 8 gauge vacuum assisted biopsy devices. Materials and methods: Hospital records of all consecutive stereotactic core biopsies performed over five years were retrospectively reviewed in compliance Health Insurance Portability and Accountability Act (HIPPA) policy and with approval from the hospital institutional review board (IRB). Pathology from core biopsy was compared with surgical pathology and/or imaging follow-up. A histological underestimation was defined if the surgical excision yielded a higher grade on pathology which changed management. Results: 828 needle core biopsies (47.5%, 393/828 with 11 gauge and 52.5%, 435/828 with 8 gauge) yielded 471 benign, 153 high risk and 204 malignant lesions. 30/193 (15.5%) 11 gauge lesions and 16/185 (8.6%) 8 gauge lesions demonstrated higher grade pathology on surgical excision. The difference in the rates of the number of correct diagnoses on core needle biopsy between 11 gauge (363/393, 92.4%) and 8 gauge (419/435, 96.3%) based on either surgical or clinical/imaging follow up and the difference in the number of discordant benign core biopsies between 11 (17/217, 7.8%) and 8 gauge (4/254, 1.6%) necessitating a surgical biopsy was significant (P = 0.013; P = 0.001). Although there were more underestimations with the 11 gauge (25/193, 13.0%) than 8 gauge (15/185, 8.1%) needle, this was not significant. Conclusion: Our study demonstrates improved performance and increased diagnostic ability of 8 gauge needle over 11 gauge in obtaining a correct diagnosis on needle biopsy.

  11. Pelton turbine Needle erosion prediction based on 3D three- phase flow simulation

    International Nuclear Information System (INIS)

    Chongji, Z; Yexiang, X; Wei, Z; Yangyang, Y; Lei, C; Zhengwei, W

    2014-01-01

    Pelton turbine, which applied to the high water head and small flow rate, is widely used in the mountainous area. During the operation period the sediment contained in the water does not only induce the abrasion of the buckets, but also leads to the erosion at the nozzle which may damage the needle structure. The nozzle and needle structure are mainly used to form high quality cylindrical jet and increase the efficiency of energy exchange in the runner to the most. Thus the needle erosion will lead to the deformation of jet, and then may cause the efficiency loss and cavitation. The favourable prediction of abrasion characteristic of needle can effectively guide the optimization design and maintenance of needle structure. This paper simulated the unsteady three-dimensional multi-phase flow in the nozzle and injected jet flow. As the jet containing water and sediment is injected into the free atmosphere air with high velocity, the VOF model was adopted to predict the water and air flow. The sediment is simplified into round solid particle and the discrete particle model (DPM) was employed to predict the needle abrasion characteristic. The sand particle tracks were analyzed to interpret the mechanism of sand erosion on the needle surface. And the numerical result of needle abrasion was obtained and compared with the abrasion field observation. The similarity of abrasion pattern between the numerical results and field observation illustrated the validity of the 3D multi-phase flow simulation method

  12. Pelton turbine Needle erosion prediction based on 3D three- phase flow simulation

    Science.gov (United States)

    Chongji, Z.; Yexiang, X.; Wei, Z.; Yangyang, Y.; Lei, C.; Zhengwei, W.

    2014-03-01

    Pelton turbine, which applied to the high water head and small flow rate, is widely used in the mountainous area. During the operation period the sediment contained in the water does not only induce the abrasion of the buckets, but also leads to the erosion at the nozzle which may damage the needle structure. The nozzle and needle structure are mainly used to form high quality cylindrical jet and increase the efficiency of energy exchange in the runner to the most. Thus the needle erosion will lead to the deformation of jet, and then may cause the efficiency loss and cavitation. The favourable prediction of abrasion characteristic of needle can effectively guide the optimization design and maintenance of needle structure. This paper simulated the unsteady three-dimensional multi-phase flow in the nozzle and injected jet flow. As the jet containing water and sediment is injected into the free atmosphere air with high velocity, the VOF model was adopted to predict the water and air flow. The sediment is simplified into round solid particle and the discrete particle model (DPM) was employed to predict the needle abrasion characteristic. The sand particle tracks were analyzed to interpret the mechanism of sand erosion on the needle surface. And the numerical result of needle abrasion was obtained and compared with the abrasion field observation. The similarity of abrasion pattern between the numerical results and field observation illustrated the validity of the 3D multi-phase flow simulation method.

  13. [From manual workshop to international standard maker: exploration on production standard of acupuncture needle by Chengjiang acupuncture school].

    Science.gov (United States)

    Cheng, Jie; Cao, Yang; Xia, Youbing

    2015-02-01

    ABSTRACT The exploration course on production standard of acupuncture needle by Chengjiang acupuncture school is reviewed in this paper. After new China was established, acupuncture needle standard was unified by Mr. CHENG Dan-an, which guided Suzhou Hua Erfang (predecessor of Suzhou Medical Supplies Factory) to make the quality standards and testing methods of acupuncture needle and improved the production process to make the modern acupuncture needle. Based on this, Suzhou Medical Supplies Factory followed the time development pace, ac tively introduced new technology, carried out technological innovation, and constantly improved the level of production technology, as a result, it gradually developed into one of the world's largest acupuncture needle production suppliers. Meanwhile, after establishing China's first national standard on acupuncture needle (GB 2024-1980), the Suzhou Medical Supplies Factory took the lead to draft "ISO) 17218:2014 the disposable use asepsis acupuncture needle", which was officially published as an international standard. The Suzhou Medical Supplies Factory developed from a manual workshop to an international standard maker.

  14. Relations between Scots pine needle element concentrations and decreased needle longevity along pollution gradients

    International Nuclear Information System (INIS)

    Lamppu, Jukka; Huttunen, Satu

    2003-01-01

    Deceased needle longevity was related to increased heavy metal concentrations. - Scots pine (Pinus sylvestris L.) shoots were sampled along transects near one urban pollution source and two smelters. Needle Mg, P and K concentrations decreased from the second to the fourth age class linearly with needle survival along the urban pollution gradient. Still, over 80% of the average concentration of these nutrients remained in the fourth needle age class. Decreased needle longevity was closely related to the increased heavy metal concentrations near the smelters. Near the urban pollution source, it was related to the increased annual needle mass and the increased needle nutrient concentrations. Decreased Mn accumulation along with needle age was detected near all pollution sources. Leaching of Mn from needles and especially from soil as a cause of decreased needle concentrations is discussed

  15. Pneumatically Operated MRI-Compatible Needle Placement Robot for Prostate Interventions

    Science.gov (United States)

    Fischer, Gregory S.; Iordachita, Iulian; Csoma, Csaba; Tokuda, Junichi; Mewes, Philip W.; Tempany, Clare M.; Hata, Nobuhiko; Fichtinger, Gabor

    2011-01-01

    Magnetic Resonance Imaging (MRI) has potential to be a superior medical imaging modality for guiding and monitoring prostatic interventions. The strong magnetic field prevents the use of conventional mechatronics and the confined physical space makes it extremely challenging to access the patient. We have designed a robotic assistant system that overcomes these difficulties and promises safe and reliable intra-prostatic needle placement inside closed high-field MRI scanners. The robot performs needle insertion under real-time 3T MR image guidance; workspace requirements, MR compatibility, and workflow have been evaluated on phantoms. The paper explains the robot mechanism and controller design and presents results of preliminary evaluation of the system. PMID:21686038

  16. A New Ultrasound-Guided Puncture Device with Augmented Degrees of Performance Freedom and Ability to Attach to Most Convex Probes

    International Nuclear Information System (INIS)

    Jung, Sung Il; Son, Kyu Ri; Kim, Young Jun; Jeon, Hae Jeong; Park, Sang Woo; Cho, Jeong Yeon; Kim, Seung Hyup

    2008-01-01

    To evaluate the performance of a newly-designed ultrasound (US)-guided puncture device. A newly-designed US-guided puncture device was composed of a guide segment and an attachable segment. The guide segment allowed the needle to be placed in the plane of US view with a maximal degree of freedom, and the attachable segment was designed to attach to most convex US probes. Six operators punctured 144 targets in phantoms using either the new device (n = 72) or free-hand technique (n = 72). The number of required needle passages and the necessary procedure times were compared between the two groups. The number of required needle passages and the necessary procedure time were significantly reduced in five operators when the newly-designed US-guided puncture device was used (p < 0.05). A newly-designed US-guided puncture device, which allows for a maximal degree of freedom in needle placement and can attach to most convex US probes, showed good performance in our study

  17. The effectiveness of inking needle core prostate biopsies for preventing patient specimen identification errors: a technique to address Joint Commission patient safety goals in specialty laboratories.

    Science.gov (United States)

    Raff, Lester J; Engel, George; Beck, Kenneth R; O'Brien, Andrea S; Bauer, Meagan E

    2009-02-01

    The elimination or reduction of medical errors has been a main focus of health care enterprises in the United States since the year 2000. Elimination of errors in patient and specimen identification is a key component of this focus and is the number one goal in the Joint Commission's 2008 National Patient Safety Goals Laboratory Services Program. To evaluate the effectiveness of using permanent inks to maintain specimen identity in sequentially submitted prostate needle biopsies. For a 12-month period, a grossing technician stained each prostate core with permanent ink developed for inking of pathology specimens. A different color was used for each patient, with all the prostate cores from all vials for a particular patient inked with the same color. Five colors were used sequentially: green, blue, yellow, orange, and black. The ink was diluted with distilled water to a consistency that allowed application of a thin, uniform coating of ink along the edges of the prostate core. The time required to ink patient specimens comprising different numbers of vials and prostate biopsies was timed. The number and type of inked specimen discrepancies were evaluated. The identified discrepancy rate for prostate biopsy patients was 0.13%. The discrepancy rate in terms of total number of prostate blocks was 0.014%. Diluted inks adhered to biopsy contours throughout tissue processing. The tissue showed no untoward reactions to the inks. Inking did not affect staining (histochemical or immunohistochemical) or pathologic evaluation. On average, inking prostate needle biopsies increases grossing time by 20%. Inking of all prostate core biopsies with colored inks, in sequential order, is an aid in maintaining specimen identity. It is a simple and effective method of addressing Joint Commission patient safety goals by maintaining specimen identity during processing of similar types of gross specimens. This technique may be applicable in other specialty laboratories and high

  18. Percutaneous needle-biopsy of the adrenal glands

    International Nuclear Information System (INIS)

    Wernecke, K.; Galanski, M.

    1986-01-01

    This account of techniques, range of indications and results of percutaneous adrenal biopsy refers to communications in the literature and to the authors' own experience. Lateral, transhepatic aspiration of adrenal material guided by sonographic control is more easy in the right adrenal gland. Punctation of the left adrenal gland ought to be done from the back and guided by computerized tomography, also in order to leave spleen, kidney, pancreas and stomach as unaffected as possible. The most frequent problem indicating adrenal biopsy still is differentiation between metastases or encretorily non-active adenomas in tumor patients. Experienced examiners will achieve an 80 to 90% sensitivity of adrenal biopsy. Clinically established, suspected phaeochromocytoma is an absolute contra-indication to fine-needle biopsy. (orig./MG) [de

  19. Performance of a New Blunt-Tip Coaxial Needle for Percutaneous Biopsy and Drainage of "Hard-To-Reach" Targets.

    Science.gov (United States)

    Cazzato, Roberto Luigi; Garnon, Julien; Shaygi, Behnam; Caudrelier, Jean; Bauones, Salem; Tsoumakidou, Georgia; Koch, Guillaume; Gangi, Afshin

    2017-09-01

    To present a new blunt-tip coaxial needle (SoftGuard) applied to access "hard-to-reach" targets undergoing percutaneous image-guided biopsy or drainage. All consecutive patients presenting between August and December 2016 with "hard-to-reach" (blunt-tip needle is a safe and effective tool when applied as a coaxial working cannula for percutaneous biopsy or drainage of "hard-to-reach" targets.

  20. INITIAL EXPERIENCE WITH ENDOSCOPIC ULTRASOUND-GUIDED FINE NEEDLE ASPIRATION OF RENAL MASSES: indications, applications and limitations

    Directory of Open Access Journals (Sweden)

    Renata Nobre MOURA

    2014-12-01

    Full Text Available Context Tissue sampling of renal masses is traditionally performed via the percutaneous approach or laparoscopicaly. The utility of endoscopic ultrasound to biopsy renal lesions it remains unclear and few cases have been reported. Objectives To evaluate the feasibility and outcome of endoscopic ultrasound fine needle aspiration of renal tumors. Methods Consecutive subjects undergoing attempted endoscopic ultrasound fine needle aspiration of a kidney mass after evaluation with computerized tomography or magnetic resonance. Results Ten procedures were performed in nine male patients (median age 54.7 years on the right (n = 4 and left kidney (n = 4 and bilaterally (n = 1. Kidney masses (median diameter 55 mm ; range 13-160 mm were located in the upper pole (n = 3, the lower pole (n = 2 and the mesorenal region (n = 3. In two cases, the mass involved more than one kidney region. Surgical resection confirmed renal cell carcinoma in six patients in whom pre-operative endoscopic ultrasound fine needle aspiration demonstrated renal cell carcinoma. No complications were reported. Conclusions Endoscopic ultrasound fine needle aspiration appears as a safe and feasible procedure with good results and minimal morbidity.

  1. Needle path planning and steering in a three-dimensional non-static environment using two-dimensional ultrasound images

    Science.gov (United States)

    Vrooijink, Gustaaf J.; Abayazid, Momen; Patil, Sachin; Alterovitz, Ron; Misra, Sarthak

    2015-01-01

    Needle insertion is commonly performed in minimally invasive medical procedures such as biopsy and radiation cancer treatment. During such procedures, accurate needle tip placement is critical for correct diagnosis or successful treatment. Accurate placement of the needle tip inside tissue is challenging, especially when the target moves and anatomical obstacles must be avoided. We develop a needle steering system capable of autonomously and accurately guiding a steerable needle using two-dimensional (2D) ultrasound images. The needle is steered to a moving target while avoiding moving obstacles in a three-dimensional (3D) non-static environment. Using a 2D ultrasound imaging device, our system accurately tracks the needle tip motion in 3D space in order to estimate the tip pose. The needle tip pose is used by a rapidly exploring random tree-based motion planner to compute a feasible needle path to the target. The motion planner is sufficiently fast such that replanning can be performed repeatedly in a closed-loop manner. This enables the system to correct for perturbations in needle motion, and movement in obstacle and target locations. Our needle steering experiments in a soft-tissue phantom achieves maximum targeting errors of 0.86 ± 0.35 mm (without obstacles) and 2.16 ± 0.88 mm (with a moving obstacle). PMID:26279600

  2. Utility of core biopsy with concurrent ROSE FNA in the diagnosis of pancreatic tumor-does the biopsy add any diagnostic benefit?

    Science.gov (United States)

    Yan, Lei; Ikemura, Kenji; Park, Ji-Weon

    2018-02-01

    Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) and endoscopic ultrasound-guided core-needle biopsy (EUS-CNB) are widely used for diagnosis of pancreatic tumors. The aim of our study was to compare the diagnostic performance of ROSE EUS-FNA and EUS-CNB for diagnosis of pancreatic malignancy during the same EUS. Patients who underwent both FNA and CNB during the same EUS for pancreatic solid lesion were reviewed retrospectively. Sample adequacy, diagnostic yield (defined as percentage of definitive diagnosis), sensitivity and specificity for malignancy were compared between FNA and CNB. A total of 48 patients with solid pancreatic lesions were evaluated. The proportions of adequate samples were 48/48 (100%) for FNA and 45/48 (93.7%) for core biopsy (P = .24). The diagnostic yield was 42/48 (87.5%) and 33/48 (68.7%) for FNA and CNB respectively (P = .046). The incremental increase in diagnostic yield by combining both methods was 2/48 (4%). The diagnostic yield for malignancy was 30/32 (93.7%) for FNA and 23/32 (71.8%) for CNB (P = .043). The sensitivity for the diagnosis of malignancy for FNA and CNB were 90.6% and 69%, respectively (P = .045). The specificity was 100% for both methods. The sensitivity for diagnosing malignancy increased to 93.8% when the two methods were combined. The difference in diagnostic yield was not associated with lesion size or location. EUS-guided FNA is a superior method of assessing solid pancreatic lesion and pancreatic malignancy with better diagnostic yield and higher sensitivity than EUS-CNB. © 2017 Wiley Periodicals, Inc.

  3. Utility and Safety of Endoscopic Ultrasound With Bronchoscope-Guided Fine-Needle Aspiration in Mediastinal Lymph Node Sampling: Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Dhooria, Sahajal; Aggarwal, Ashutosh N; Gupta, Dheeraj; Behera, Digambar; Agarwal, Ritesh

    2015-07-01

    The use of endoscopic ultrasound with bronchoscope-guided fine-needle aspiration (EUS-B-FNA) has been described in the evaluation of mediastinal lymphadenopathy. Herein, we conduct a meta-analysis to estimate the overall diagnostic yield and safety of EUS-B-FNA combined with endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA), in the diagnosis of mediastinal lymphadenopathy. The PubMed and EmBase databases were searched for studies reporting the outcomes of EUS-B-FNA in diagnosis of mediastinal lymphadenopathy. The study quality was assessed using the QualSyst tool. The yield of EBUS-TBNA alone and the combined procedure (EBUS-TBNA and EUS-B-FNA) were analyzed by calculating the sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio for each study, and pooling the study results using a random effects model. Heterogeneity and publication bias were assessed for individual outcomes. The additional diagnostic gain of EUS-B-FNA over EBUS-TBNA was calculated using proportion meta-analysis. Our search yielded 10 studies (1,080 subjects with mediastinal lymphadenopathy). The sensitivity of the combined procedure was significantly higher than EBUS-TBNA alone (91% vs 80%, P = .004), in staging of lung cancer (4 studies, 465 subjects). The additional diagnostic gain of EUS-B-FNA over EBUS-TBNA was 7.6% in the diagnosis of mediastinal adenopathy. No serious complication of EUS-B-FNA procedure was reported. Clinical and statistical heterogeneity was present without any evidence of publication bias. Combining EBUS-TBNA and EUS-B-FNA is an effective and safe method, superior to EBUS-TBNA alone, in the diagnosis of mediastinal lymphadenopathy. Good quality randomized controlled trials are required to confirm the results of this systematic review. Copyright © 2015 by Daedalus Enterprises.

  4. Cloned foal derived from in vivo matured horse oocytes aspirated by the short disposable needle system

    OpenAIRE

    Lee, Wonyou; Song, Kilyoung; Lee, Inhyung; Shin, Hyungdo; Lee, Byeong Chun; Yeon, Seongchan; Jang, Goo

    2015-01-01

    Transvaginal ultrasound-guided follicle aspiration is one method of obtaining recipient oocytes for equine somatic cell nuclear transfer (SCNT). This study was conducted: (1) to evaluate the possibility of oocyte aspiration from pre-ovulatory follicles using a short disposable needle system (14-G) by comparing the oocyte recovery rate with that of a long double lumen needle (12-G); (2) to investigate the developmental competence of recovered oocytes after SCNT and embryo transfer. The recover...

  5. The core business web a guide to key information resources

    CERN Document Server

    White, Gary W

    2013-01-01

    The best Business Web sites at your fingertips—24/7! The Core Business Web: A Guide to Key Information Resources is an essential resource that saves you from spending hours searching through thousands of Web sites for the business information you need. A distinguished panel of authors, all active in business librarianship, explores Web sites in their subject areas, selecting the very best from 25 functional areas of business. Each site was chosen based on the timeliness, relevance and reliability of its content, the site's ease of navigation and use, and the authority of the site's author or publisher. The rapid growth of the Internet has resulted in an ever-increasing number of Web sites offering potentially useful business information. The Core Business Web identifies, evaluates, and summarizes the most significant sites, including gateways or portals, directories, and meta-sites, to organize online resources into easy-to-follow links that allow you to access information quickly. Sites are categorized and ...

  6. Influence of needle position on lumbar segmental nerve root block selectivity.

    Science.gov (United States)

    Wolff, André P; Groen, Gerbrand J; Wilder-Smith, Oliver H

    2006-01-01

    In patients with chronic low back pain radiating to the leg, segmental nerve root blocks (SNRBs) are performed to predict surgical outcome and identify the putative symptomatic spinal nerve. Epidural spread may lead to false interpretation, affecting clinical decision making. Systematic fluoroscopic analysis of epidural local anesthetic spread and its relationship to needle tip location has not been published to date. Study aims include assessment of epidural local anesthetic spread and its relationship to needle position during fluoroscopy-assisted blocks. Patients scheduled for L4, L5, and S1 blocks were included in this prospective observational study. Under fluoroscopy and electrostimulation, they received 0.5 mL of a mixture containing lidocaine 5 mg and iohexol 75 mg. X-rays with needle tip and contrast were scored for no epidural spread (grade 0), local spread epidurally (grade 1), or to adjacent nerve roots (grade 2). Sixty-five patients were analyzed for epidural spread, 62 for needle position. Grade 1 epidural spread occurred in 47% of L4 and 28% of L5 blocks and grade 2 spread in 3 blocks (5%; L5 n = 1, S1 n = 2). For lumbar blocks, the needle was most frequently found in the lateral upper half of the intervertebral foramen. Epidural spread occurred more frequently with medial needle positions (P = .06). The findings suggest (P = .06) that the risk of grade 1 and 2 lumbar epidural spread, which results in decreased SNRB selectivity, is greater with medial needle positions in the intervertebral foramen. The variability in anatomic position of the dorsal root ganglion necessitates electrostimulation to guide SNRB in addition to fluoroscopy.

  7. CT and fluoroscopy guided celiac ganglion block

    International Nuclear Information System (INIS)

    Lim, Sun Kyung; Kwon, Dae Ik; Ahn, Hyup; Kim, Jong Il; Kim, Byung Young; Lee, Jong Gil

    1994-01-01

    To evaluate the effects and usefulness of fluoroscopy guided celiac ganglion block after marking of needle path with CT scan. Celiac ganglion block with 100% ethyl alcohol was performed in 50 cancer patients who were inoperable and had intractable abdominal pain. Duration and degree of pain relief after the procedure and its complication were analyzed. Early pain relief was observed in 98% and long term relief in 68% without serious complication. Fluoroscopy guided celiac ganglion block after marking of needle path with CT scan was a safe and valuable procedure in relieving intractable pain in terminal cancer patients and reduced the time in the CT room

  8. Mechanics of needle-tissue interaction

    NARCIS (Netherlands)

    Roesthuis, Roy; van Veen, Youri; Jahya, Alex; Misra, Sarthak

    2011-01-01

    When a needle is inserted into soft tissue, interac- tion forces are developed at the needle tip and along the needle shaft. The needle tip force is due to cutting of the tissue, and the force along the needle shaft is due to friction between needle and tissue. In this study, the friction force is

  9. Precipitation of Oriented Rutile and Ilmenite Needles in Garnet, Northeastern Connecticut, USA: Evidence for Extreme Metamorphic Conditions?

    Science.gov (United States)

    Ague, J. J.; Eckert, J. O.

    2011-12-01

    We report the discovery of oriented needles of rutile and, less commonly, ilmenite in the cores of garnets from northeastern CT, USA. The rocks preserve granulite facies mineral assemblages, form part of the Merrimack Synclinorium, and underwent metamorphism and deformation during the Acadian orogeny. The needles appear identical to those reported from a number of extreme P-T environments worldwide, including UHP metamorphic rocks, high-P granulites, and garnet peridotites. The needles are predominantly oriented along directions in garnet. The long axes of the rutile needles commonly do not go extinct parallel to the cross hairs under cross-polarized light (e.g., Griffin et al., 1971). This anomalous extinction indicates that the needles do not preserve a specific crystallographic relationship with their garnet hosts (e.g., Hwang et al., 2007). The needles range from a few hundred nm to a few um in diameter, and can be mm-scale in length. Micrometer-scale plates of rutile, srilankite and crichtonite have also been observed in some garnets together with the Fe-Ti oxide needles. Several origins for the needles have been proposed in the literature; we investigate the hypothesis that they precipitated in situ from originally Ti-rich garnet. Chemical profiles across garnets indicate that some retain Ti zoning, with elevated-Ti concentrations in the cores dropping to low values in the rims. For these zoned garnets, high-resolution, 2-D chemical mapping using the JEOL JXA-8530F field emission gun electron microprobe at Yale University reveals that the needles are surrounded by well-defined Ti-depletion halos. Chemical profiles also document strong depletions of Cr (which is present in both rutile and ilmenite) directly adjacent to needles. The observed Ti-depletions demonstrate that the needles precipitated from Ti-bearing garnet, probably during cooling and/or decompression associated with exhumation. The rutile precipitates must be largely incoherent with respect to the

  10. Relationship of pancreatic mass size and diagnostic yield of endoscopic ultrasound-guided fine needle aspiration.

    Science.gov (United States)

    Siddiqui, Ali A; Brown, Lauren J; Hong, Shih-Kuang S; Draganova-Tacheva, Rossitza A; Korenblit, Jason; Loren, David E; Kowalski, Thomas E; Solomides, Charalambos

    2011-11-01

    Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is central to discerning the diagnosis of solid pancreatic tumors through tissue acquisition. Test performance is affected by a number of factors including location of mass within the pancreas, presence of onsite cytology technologist, and number of passes with the needle. The influence of tumor size has not been well studied. The objective of the current study was to determine whether the size of mass affects the diagnostic accuracy for solid pancreatic lesions aspirated under EUS guidance. Data were collected retrospectively on all patients with solid pancreatic masses undergoing EUS-FNA from June 2003 to August 2010. The cytology samples were reported as positive, suspicious for malignancy, atypical, negative, or nondiagnostic. The gold standard for a cytological diagnosis was histological confirmation or clinical follow-up of more than 6 months with repeat imaging. Patients were divided into five groups based upon lesion size as follows: (a) less than 1 cm, (b) 1-2 cm, (c) 2-3 cm, (d) 3-4 cm, and (e) greater than 4 cm. Performance characteristics of EUS-FNA including sensitivity, specificity, and accuracy were compared for each group. Accuracy was defined as the ratio of the sum of true-positive and true-negative values divided by the number of lesions. We identified 583 patients with solid pancreatic lesions in which EUS-FNA was performed and adequate cellularity was obtained (47% men, mean age 65 ± 1.4 (SE) years). Overall, 486 (83%) of lesions were pancreatic adenocarcinoma, 18 (3%) were neuroendocrine tumors, 12 (2%) were lymphomas, and 67 (12%) were benign lesions. The median size of the mass was 3 cm (range, 0.5-7 cm). A mean of 4.9 passes (range, 1-9 passes) was needed to obtain adequate samples from lesions. The overall yield of obtaining adequate samples for diagnosis was 85%. When stratified by size, the EUS-FNA sensitivity for lesions with size 4 cm was 40, 75.9, 86.9, 93

  11. False Negative Fine Needle Aspiration Biopsy Results in Primary Thyroid Lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Kim, In Joong; Kim, Eun Kyung; Koh, Myoung Ju; Kwak, Jin Young; Moon, Hee Jung [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2012-06-15

    Ultrasonography-guided fine needle aspiration biopsy (US-FNA) is one of the methods used to diagnose thyroid lymphoma, but it has a relatively high false-negative rate. The authors report a case of a primary thyroid lymphoma associated with underlying lymphocytic thyroiditis that was initially misdiagnosed as lymphocytic thyroiditis based on US-FNA findings

  12. A review of the benefits and pitfalls of phantoms in ultrasound-guided regional anesthesia.

    Science.gov (United States)

    Hocking, Graham; Hebard, Simon; Mitchell, Christopher H

    2011-01-01

    With the growth of ultrasound-guided regional anesthesia, so has the requirement for training tools to practice needle guidance skills and evaluate echogenic needles. Ethically, skills in ultrasound-guided needle placement should be gained in a phantom before performance of nerve blocks on patients in clinical practice. However, phantom technology is varied, and critical evaluation of the images is needed to understand their application to clinical use. Needle visibility depends on the echogenicity of the needle relative to the echogenicity of the tissue adjacent the needle. We demonstrate this point using images of echogenic and nonechogenic needles in 5 different phantoms at both shallow angles (20 degrees) and steep angles (45 degrees). The echogenicity of phantoms varies enormously, and this impacts on how needles are visualized. Water is anechoic, making all needles highly visible, but does not fix the needle to allow practice placement. Gelatin phantoms and Blue Phantoms provide tactile feedback but have very low background echogenicity, which greatly exaggerates needle visibility. This makes skill acquisition easier but can lead to false confidence in regard to clinical ability. Fresh-frozen cadavers retain much of the textural feel of live human tissue and are nearly as echogenic. Similar to clinical practice, this makes needles inserted at steep angles practically invisible, unless they are highly echogenic. This review describes the uses and pitfalls of phantoms that have been described or commercially produced. Copyright © 2011 by American Society of Regional Anesthesia and Pain Medicine

  13. Role of endoscopic ultrasound-guided fine-needle aspiration in adrenal lesions: analysis of 32 patients

    Directory of Open Access Journals (Sweden)

    Rakesh K Gupta

    2018-01-01

    Full Text Available Objective: Endoscopic ultrasound-guided fine-needle aspiration cytology (EUS-FNAC is a precise and safe technique that provides both radiological and pathological diagnosis with a better diagnostic yield and minimal adverse events. EUS-FNAC led to the remarkable increase in the detection rate of incidentaloma found during radiologic staging or follow-up in various malignancy or unrelated conditions. Aims: We did this preliminary study with an aim to evaluate the role of EUS-FNA in diagnosing and classifying adrenal lesions, clinical impact, and compare the outcome with the previously published literature. Materials and Methods: We included 32 consecutive cases (both retrospective and prospective of EUS-guided adrenal aspirate performed over a period of 3.3 years. The indications for the aspirate in decreasing order were metastasis (most common carcinoma gall bladder > primary adrenal mass > disseminated tuberculosis > pyrexia of unknown origin. On EUS, 28 cases revealed space occupying lesion or mass (two cases bilateral and four cases revealed diffuse enlargement (two cases bilateral with a mean size of 21 mm. Results: The cytology reports were benign adrenal aspirate (43.8%, metastatic adenocarcinoma (15.6%, histoplasmosis (9.4%, tuberculosis (9.4%, round cell tumor (6.2%, adrenocortical carcinoma (3.1%, and descriptive (3.1%. Three cases (9.4% yielded inadequate sample. The TNM staging was altered in 22.23% of the cases by result of adrenal aspirate. Conclusions: EUS-FNA of the adrenal gland is a safe, quick, and sensitive and real-time diagnostic technique, which requires an integrated approach of clinician, endoscopist, and cytopathologist for high precision in diagnosis. Although the role of EUS-FNA for right adrenal is not much described, we found adequate sample yield in all the four patients that underwent the procedure.

  14. Technical Aspects of Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration: CHEST Guideline and Expert Panel Report.

    Science.gov (United States)

    Wahidi, Momen M; Herth, Felix; Yasufuku, Kazuhiro; Shepherd, Ray Wesley; Yarmus, Lonny; Chawla, Mohit; Lamb, Carla; Casey, Kenneth R; Patel, Sheena; Silvestri, Gerard A; Feller-Kopman, David J

    2016-03-01

    Endobronchial ultrasound (EBUS) was introduced in the last decade, enabling real-time guidance of transbronchial needle aspiration (TBNA) of mediastinal and hilar structures and parabronchial lung masses. The many publications produced about EBUS-TBNA have led to a better understanding of the performance characteristics of this procedure. The goal of this document was to examine the current literature on the technical aspects of EBUS-TBNA as they relate to patient, technology, and proceduralist factors to provide evidence-based and expert guidance to clinicians. Rigorous methodology has been applied to provide a trustworthy evidence-based guideline and expert panel report. A group of approved panelists developed key clinical questions by using the PICO (population, intervention, comparator, and outcome) format that addressed specific topics on the technical aspects of EBUS-TBNA. MEDLINE (via PubMed) and the Cochrane Library were systematically searched for relevant literature, which was supplemented by manual searches. References were screened for inclusion, and well-recognized document evaluation tools were used to assess the quality of included studies, to extract meaningful data, and to grade the level of evidence to support each recommendation or suggestion. Our systematic review and critical analysis of the literature on 15 PICO questions related to the technical aspects of EBUS-TBNA resulted in 12 statements: 7 evidence-based graded recommendations and 5 ungraded consensus-based statements. Three questions did not have sufficient evidence to generate a statement. Evidence on the technical aspects of EBUS-TBNA varies in strength but is satisfactory in certain areas to guide clinicians on the best conditions to perform EBUS-guided tissue sampling. Additional research is needed to enhance our knowledge regarding the optimal performance of this effective procedure. Copyright © 2016 American College of Chest Physicians. Published by Elsevier Inc. All rights

  15. Education and training for advanced practice: Principles of course design and assessment applied to a 'stereotactic needle core biopsy of the breast' module

    International Nuclear Information System (INIS)

    Dixon, Anne-Marie

    2006-01-01

    In order to realise the promise of the NHS Plan, radiographers are extending their practice to encompass tasks previously undertaken by radiologists and advancing their practice by taking responsibility for clinical decision-making and autonomous membership of multidisciplinary healthcare teams. In partnership with clinical service providers Higher Education Institutes are devising programmes of study to support such professional development. This article reviews the design of a 20 credit post-graduate (M level) module in stereotactic needle core biopsy of the breast. Particular consideration is given to underpinning educational principles of course design and assessment and how these are applied in order that teaching, learning and assessment have academic rigour and clinical competence of successful students is assured

  16. In-plane ultrasonic needle tracking using a fiber-optic hydrophone

    Energy Technology Data Exchange (ETDEWEB)

    Xia, Wenfeng, E-mail: wenfeng.xia@ucl.ac.uk; Desjardins, Adrien E. [Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London WC1E 6BT (United Kingdom); Mari, Jean Martial [Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London WC1E 6BT, United Kingdom and GePaSud, University of French Polynesia, Faa’a 98702, French Polynesia (France); West, Simeon J. [Department of Anaesthesia, University College Hospital, Main Theatres, Maple Bridge Link Corridor, Podium 3, 235 Euston Road, London NW1 2BU (United Kingdom); Ginsberg, Yuval; David, Anna L. [Institute for Women’s Health, University College London, 86-96 Chenies Mews, London WC1E 6HX (United Kingdom); Ourselin, Sebastien [Center for Medical Imaging Computing, University College London, Gower Street, London WC1E 6BT (United Kingdom)

    2015-10-15

    the needle tip in water, the SNR of the needle tip varied with insertion angle, attaining values of 284 at 27° and 501 at 68°. In swine tissue ex vivo, the SNR decreased from 80 at 15° to 16 at 61°. In swine tissue in vivo, the SNR varied with depth, from 200 at 17.5 mm to 48 at 26 mm, with a constant insertion angle of 40°. In ovine tissue in vivo, within the uterine cavity, the SNR varied from 46.4 at 25 mm depth to 18.4 at 32 mm depth, with insertion angles in the range of 26°–65°. Conclusions: A fiber-optic ultrasound receiver integrated into the needle cannula in combination with single-element transmissions from the imaging probe allows for direct visualization of the needle tip within the ultrasound imaging plane. Visualization of the needle tip was achieved at depths and insertion angles that are encountered during nerve blocks and fetal interventions. The method presented in this paper has strong potential to improve the safety and efficiency of ultrasound-guided needle insertions.

  17. A novel semi-robotized device for high-precision 18F-FDG-guided breast cancer biopsy.

    Science.gov (United States)

    Hellingman, D; Teixeira, S C; Donswijk, M L; Rijkhorst, E J; Moliner, L; Alamo, J; Loo, C E; Valdés Olmos, R A; Stokkel, M P M

    To assess the 3D geometric sampling accuracy of a new PET-guided system for breast cancer biopsy (BCB) from areas within the tumour with high 18 F-FDG uptake. In the context of the European Union project MammoCare, a prototype semi-robotic stereotactic prototype BCB-device was incorporated into a dedicated high resolution PET-detector for breast imaging. The system consists of 2 stacked rings, each containing 12 plane detectors, forming a dodecagon with a 186mm aperture for 3D reconstruction (1mm 3 voxel). A vacuum-assisted biopsy needle attached to a robot-controlled arm was used. To test the accuracy of needle placement, the needle tip was labelled with 18 F-FDG and positioned at 78 target coordinates distributed over a 35mm×24mm×28mm volume within the PET-detector field-of-view. At each position images were acquired from which the needle positioning accuracy was calculated. Additionally, phantom-based biopsy proofs, as well as MammoCare images of 5 breast cancer patients, were evaluated for the 3D automated locating of 18 F-FDG uptake areas within the tumour. Needle positioning tests revealed an average accuracy of 0.5mm (range 0-1mm), 0.6mm (range 0-2mm), and 0.4mm (range 0-2mm) for the x/y/z-axes, respectively. Furthermore, the MammoCare system was able to visualize and locate small (cancer core needle biopsy. Its clinical feasibility evaluation in breast cancer patients scheduled for neo-adjuvant chemotherapy will follow. Copyright © 2016 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  18. The decrease effect of music on anxiety and distress of patients undergoing ultrasound guided core biopsy of the breast

    Energy Technology Data Exchange (ETDEWEB)

    Woo, Ae Rang [Dept. of Diagnostic Radiology, St. Carollo General Hospital, Suncheon (Korea, Republic of); Sohn, Seok Joon [Dept. of Preventive Medicine, Chonnam National University Medical School, Chonnam National University Hospital, Gwangju (Korea, Republic of); Moon, Il Bong; Dong, Kyung Rae [Dept. of Radiological Technology, Gwangju Health University, Gwangju (Korea, Republic of)

    2017-06-15

    The aim of this study was to investigate that listening to music reduces the anxiety and distress of the patients who underwent ultrasound guided core biopsy in a clinic. One hundred patients underwent Ultrasound Guided Core Biopsy of the Breast. Each patients was allocated to one of two groups with different methods whether they listened to music or not. The experimental group listening to music are 50 patients and the control group are 50 patients. The difference of VAS anxiety score of pre-test and post-test was signifcant (p<0.001). Compared by the control group, the subjective distress of the patients listening to music such as pain and tension was significant (p<0.001) but nausea and dyspnea was not significant. The objective distress of the patients listening to music was statistically significant (p<0.001). The Differances of systolic blood pressure, diastolic blood pressure, pulse between pre-test and post-test were not signifcant. The results suggest that listening to music reduces the anxiety and distress of the patients who underwent ultrasound guided core biopsy in a clinic.

  19. The decrease effect of music on anxiety and distress of patients undergoing ultrasound guided core biopsy of the breast

    International Nuclear Information System (INIS)

    Woo, Ae Rang; Sohn, Seok Joon; Moon, Il Bong; Dong, Kyung Rae

    2017-01-01

    The aim of this study was to investigate that listening to music reduces the anxiety and distress of the patients who underwent ultrasound guided core biopsy in a clinic. One hundred patients underwent Ultrasound Guided Core Biopsy of the Breast. Each patients was allocated to one of two groups with different methods whether they listened to music or not. The experimental group listening to music are 50 patients and the control group are 50 patients. The difference of VAS anxiety score of pre-test and post-test was signifcant (p<0.001). Compared by the control group, the subjective distress of the patients listening to music such as pain and tension was significant (p<0.001) but nausea and dyspnea was not significant. The objective distress of the patients listening to music was statistically significant (p<0.001). The Differances of systolic blood pressure, diastolic blood pressure, pulse between pre-test and post-test were not signifcant. The results suggest that listening to music reduces the anxiety and distress of the patients who underwent ultrasound guided core biopsy in a clinic

  20. Investigating the Effects of Three Needling Parameters (Manipulation, Retention Time, and Insertion Site) on Needling Sensation and Pain Profiles: A Study of Eight Deep Needling Interventions

    Science.gov (United States)

    Loyeung, Bertrand Y. K.; Cobbin, Deirdre M.

    2013-01-01

    Introduction. In traditional Chinese acupuncture, needle sensation (deqi) is purported to contribute to a therapeutic outcome. While researchers have attempted to define deqi qualitatively, few have examined the effects of needling parameters on its intensity. Methods. 24 healthy subjects completed eight interventions scheduled at least one week apart, which involved manual acupuncture to LI4 or a designated nonacupoint (NAP) on the hand, with real or simulated manipulation each three minutes and needle retentions of one or 21 minutes. Intensities of needling sensation and pain were reported every three minutes and sensation qualities were reported post-intervention. Results. Immediately after needle insertion, similar levels of mean needle sensation and of pain were reported independent of intervention. At subsequent measurement times, only two interventions (one at LI4 and one at NAP) maintained statistically significantly elevated needle sensation and pain scores and reported higher numbers of needle sensation descriptors. For both, the needle was retained for 21 minutes and manipulated every three minutes. Neither intervention differed significantly in terms of levels of pain, and needle sensation or numbers and qualities of needle sensation described. Conclusion. In this group of healthy subjects, the initial needling for all eight interventions elicited similar levels of needle sensation and pain. These levels were only maintained if there was ongoing of needle manipulation and retention of the needle. By contrast, the strength of needle sensation or pain experienced was independent of insertion site. PMID:24159337

  1. Effect of needle tract bleeding on occurrence of pneumothorax after transthoracic needle biopsy

    International Nuclear Information System (INIS)

    Topal, U.; Berkman, Yahya M.

    2005-01-01

    Purpose: Occasionally bleeding along the needle trajectory is observed at post-biopsy computed tomographic sections. This study was designed to evaluate the possible effect of needle tract bleeding on the occurrence of pneumothorax and on requirement of chest tube insertion. Materials and methods: Two hundred eighty-four needle biopsies performed in 275 patients in whom the needle traversed the aerated lung parenchyma were retrospectively reviewed. Bleeding along the needle tract, occurrence of pneumothorax and need for chest tube insertion, type and size of the needle, size of the lesion, length of the lung traversed by the needle, presence or absence of emphysema were noted. Effect of these factors on the rate of pneumothorax and needle-tract bleeding was evaluated. The data were analyzed by χ 2 test. Results: Pneumothorax developed in 100 (35%) out of 284 procedures requiring chest tube placement in 16 (16%). Variables that were significantly associated with an increased risk of pneumothorax were depth of the lesion (P 0.05). However, analysis of the relation between length of lung traversed by the needle, tract-bleeding and pneumothorax rate indicated that tract-bleeding had a preventive effect on development of pneumothorax (P 0.05). Conclusion: Bleeding in the needle tract has a preventive effect on the occurrence of the pneumothorax in deep-seated lesions and in the presence of emphysema, although it does not affect the overall rate of pneumothorax

  2. Diagnosis of prostate cancer with needle biopsy: should all cases be biopsied before treatment?

    Science.gov (United States)

    Oranusi, C K; Ugezu, A I; Nwofor, Ame

    2012-01-01

    The triad of digital rectal examination (DRE), serum prostate specific antigen, and transrectal ultrasound-guided prostate biopsy is used in the detection of prostate cancer (PCa). It is recommended that all cases of PCa should be diagnosed with needle biopsy before treatment. The exclusion criteria for those that may not be suitable have not yet been defined. We reviewed all the patients diagnosed with PCa at the Nnamdi Azikiwe University Teaching Hospital Nnewi, Southeast, Nigeria, from January 2007 to December 2010. Relevant biodata and method of diagnosis of PCa before treatment were reviewed. A total of 133 patients had bilateral orchidectomy over the period. 120 (90.2%) had their diagnosis confirmed by needle biopsy before bilateral orchidectomy (category 1), while 13 (9.8%) had bilateral orchidectomy before diagnosis was confirmed. The method of diagnosis for category 1 patients was with lower urinary tract symptoms (LUTS), abnormal DRE findings, elevated prostate-specific antigen (PSA), and transrectal needle biopsy. For category 11 patients, diagnosis of PCa was suspected based on LUTS, abnormal DRE findings, and elevated PSA. Of this number, 11 (84.6%) had, in addition, sudden onset paraplegia at presentation, while 2 (15.4%) had severe uncontrolled hematuria at presentation. All the patients in both categories had needle biopsy confirmation of their disease. The sensitivity of PSA was 99.2%. Needle biopsy of the prostate is the preferred method for the diagnosis of PCa in most cases before treatment is undertaken. There are valid reasons why all PCas will not be diagnosed in this fashion. Elevated PSA when combined with an abnormal DRE finding increases the predictive value for cancer. In areas where pathologists are lacking, abnormal DRE and elevated PSA results can be a guide to proceed to treatment especially, where there is severe compromise of patients' quality of life due to symptoms of advanced PCa while awaiting confirmation.

  3. Role of Ultrasound Guided Biopsy of Thoracic Lesions | Elameen ...

    African Journals Online (AJOL)

    Objective: This prospective study is to evaluate and enhance the role of ultrasound in biopsy guidance of thoracic lesions. Methods: 55 patients were subjected for fine needle aspiration (FNA) and/or core needle biopsy (CNB) from peripheral chest lesions in Ribat University Hospital during the period from April 2011 and ...

  4. Endobronchial Ultrasound-guided Transbronchial Needle Aspiration 
in the Diagnosis of Intrathoracic Metastasis from Extrapulmonary Malignancy

    Directory of Open Access Journals (Sweden)

    Jiayuan SUN

    2015-05-01

    Full Text Available Background and objective Endobronchial ultrasound guided transbronchial needle aspiration (EBUS-TBNA has been widely applied in diagnosing mediastinal and hilar adenopathy. This study is further to evaluate value and safety of EBUS-TBNA in diagnosing intrathoracic metastasis from extrapulmonary malignancy. Methods Prospectively analysis of 41 patients suspected intrathoracic metastasis from previous diagnosed/concurrent extrapulmonary malignancies in Shanghai Chest Hospital, with radiologic findings showing mediastinal/hilar lymph node enlargement or intrapulmonary lesion requiring EBUS-TBNA examination for pathological diagnosis. Results 41 candidate patients enrolled, and 67 mediastinal/hilar lymph nodes and 5 intrapulmonary lesions were aspirated. 14 intrathoracic metastasis, 10 primary lung cancer, 9 reactive lymphadenitis, 4 sarcoid-like reactions, and 1 tuberculosis was diagnosed by EBUS-TBNA. Sensitivity and accuracy of EBUS-TBNA in diagnosing intrathoracic metastasis was 87.50% and 95.12%, respectively. Immunohistochemistry (IHC was performed in 18 malignant tumors to obtain definite type or origin, twelve intrathoracic metastasis and 6 primary lung cancer were further confirmed. Conclusion EBUS-TBNA is a safe, effective method for the diagnosis of intrathoracic metastasis from extrapulmonary malignancy. IHC can provide additional evidence for distinguishing extrapulmonary malignancy from primary lung cancer.

  5. Clinical impact of endoscopic ultrasound-guided fine needle aspiration biopsy in patients with upper gastrointestinal tract malignancies. A prospective study

    DEFF Research Database (Denmark)

    Mortensen, M B; Pless, T; Durup, J

    2001-01-01

    BACKGROUND AND STUDY AIMS: Several studies have evaluated the accuracy of endoscopic ultrasound-guided fine-needle aspiration biopsy (EUS-FNAB) in the upper gastrointestinal tract, but so far no studies have specifically evaluated the clinical impact of EUS-FNAB in upper gastrointestinal tract......% in esophageal, gastric, and pancreatic cancer, respectively. The staging-related clinical impact was similar for all three types of cancer (11-12.5%), whereas the diagnosis-related impact was highest in pancreatic cancer patients (86%). EUS-FNAB was inadequate in 13% and gave false-negative results in 5......%. The overall sensitivity, specificity and accuracy for EUS-FNAB were 80%, 78% and 80%, respectively. No complications related to the biopsy procedure were seen. CONCLUSIONS: If EUS-FNAB was performed only in cases where a positive malignant result would change patient management, then approximately one out...

  6. Core-needle biopsy of breast cancer is associated with a higher rate of distant metastases 5 to 15 years after diagnosis than FNA biopsy.

    Science.gov (United States)

    Sennerstam, Roland B; Franzén, Bo S H; Wiksell, Hans O T; Auer, Gert U

    2017-10-01

    The literature offers discordant results regarding whether diagnostic biopsy is associated with the dissemination of cancer cells, resulting in local and/or distant metastasis. The long-term outcomes of patients with breast cancer were compared between those who were diagnosed using either fine-needle aspiration biopsy (FNAB) or core-needle biopsy (CNB) during 2 decades: the 1970s and 1990s. In the 1970s, the only diagnostic needle biopsy method used for breast cancer in Sweden was FNAB. CNB was introduced 1989 and became established in Stockholm Gotland County in the early 1990s. The authors compared the clinical outcomes of patients diagnosed using FNAB from 1971 to 1976 (n = 354) versus those of patients diagnosed using CNB from 1991 to 1995 (n = 1729). Adjusting for differences in various treatment modalities, mammography screening, tumor size, DNA ploidy, and patient age between the 2 decades, 2 strictly matched samples representing FNAB (n = 181) and CNB (n = 203) were selected for a 15-year follow-up study. In a comparison of the rates of distant metastasis in the strictly matched patient groups from the FNAB and CNB cohorts, significantly higher rates of late-appearing (5-15 years after diagnosis) distant metastasis were observed among the patients who were diagnosed on CNB compared with those who were diagnosed on FNAB. No significant difference in local metastasis was observed between the 2 groups. At 5 to 15 years after diagnosis of the primary tumor, CNB-diagnosed patients had significantly higher rates of distant metastases than FNAB-diagnosed patients. Cancer Cytopathol 2017;125:748-56. © 2017 American Cancer Society. © 2017 American Cancer Society.

  7. Reduced variability and execution time to reach a target with a needle GPS system: Comparison between physicians, residents and nurse anaesthetists.

    Science.gov (United States)

    Fevre, Marie-Cécile; Vincent, Caroline; Picard, Julien; Vighetti, Arnaud; Chapuis, Claire; Detavernier, Maxime; Allenet, Benoît; Payen, Jean-François; Bosson, Jean-Luc; Albaladejo, Pierre

    2018-02-01

    Ultrasound (US) guided needle positioning is safer than anatomical landmark techniques for central venous access. Hand-eye coordination and execution time depend on the professional's ability, previous training and personal skills. Needle guidance positioning systems (GPS) may theoretically reduce execution time and facilitate needle positioning in specific targets, thus improving patient comfort and safety. Three groups of healthcare professionals (41 anaesthesiologists and intensivists, 41 residents in anaesthesiology and intensive care, 39 nurse anaesthetists) were included and required to perform 3 tasks (positioning the tip of a needle in three different targets in a silicon phantom) by using successively a conventional US-guided needle positioning and a needle GPS. We measured execution times to perform the tasks, hand-eye coordination and the number of repositioning occurrences or errors in handling the needle or the probe. Without the GPS system, we observed a significant inter-individual difference for execution time (Pgaming were found to be independent factors associated with a shorter execution time. Use of GPS attenuated the inter-individual and group variability. We observed a reduced execution time and improved hand-eye coordination in all groups as compared to US without GPS. Neither US training, video gaming nor demographic personal or professional factors were found to be significantly associated with reduced execution time when GPS was used. US associated with GPS systems may improve safety and decrease execution time by reducing inter-individual variability between professionals for needle-handling procedures. Copyright © 2016 Société française d'anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.

  8. Ultrasound-guided renal biopsy: experience using an automated core biopsy system.

    Science.gov (United States)

    Chan, R; Common, A A; Marcuzzi, D

    2000-04-01

    To assess the safety and efficacy of ultrasound-guided percutaneous renal biopsy using an automated core biopsy system, and to determine radiologists' accuracy in predicting sample adequacy. Ninety-five biopsies were performed on 25 native kidneys and 70 renal allografts using a 16-gauge automated, spring-loaded core biopsy device under real-time sonographic guidance. Radiologists performing the biopsy estimated the number of core samples needed to obtain an adequate specimen, based on visual inspection of each core. The final determination of the number of samples was made by a pathology technologist who attended each biopsy, based on preliminary microscopic examination of tissue cores. After each biopsy, an ultrasonographic examination was performed to search for biopsy-related hemorrhage, and a questionnaire was given to the patient to determine biopsy-related complications, which were categorized as either minor or major. The main indication for biopsy was acute renal failure (in 43.2% of biopsies). An average of 3 tissue cores per biopsy were obtained. Of the 94 patients in whom a biopsy was conducted to exclude diffuse renal disease, a mean of 12.5 glomeruli were present in each specimen. Overall, adequate tissue for diagnosis was obtained in 98.9% of cases. The radiologists' estimate of the number of core samples needed concurred with the pathology technologists' determination of sample adequacy in 88.4% of cases. A total of 26 complications occurred (in 27.4% of biopsies), consisting of 23 minor (24.2%) and 3 major (3.2%) complications. Real-time sonographic guidance in conjunction with an automated core biopsy system is a safe and accurate method of performing percutaneous renal biopsy. Routine use of sonographic examinations to search for biopsy-related complications is not indicated. Radiologists are accurate in estimating sample adequacy in most cases; however, the presence of a pathology technologist at the biopsy procedure virtually eliminates the

  9. Significant histologic features differentiating cellular fibroadenoma from phyllodes tumor on core needle biopsy specimens.

    Science.gov (United States)

    Yasir, Saba; Gamez, Roberto; Jenkins, Sarah; Visscher, Daniel W; Nassar, Aziza

    2014-09-01

    Cellular fibroepithelial lesions (CFELs) are a heterogeneous group of tumors encompassing cellular fibroadenoma (CFA) and phyllodes tumor (PT). Distinction between the two is challenging on core needle biopsy (CNB) specimens. The objective of this study was to evaluate histologic features that can help distinguish PT from CFA on CNB specimens. Records of all patients diagnosed with CFELs on CNB specimens with follow-up excision between January 2002 and December 2012 were retrieved. Histopathologic stromal features were evaluated on CNB specimens, including mitoses per 10 high-power fields (hpf), overgrowth, increased cellularity, fragmentation, adipose tissue infiltration, heterogeneity, subepithelial condensation, and nuclear pleomorphism. Twenty-seven (42.2%) of 64 were diagnosed as PT (24 benign PTs and three borderline PTs) and 37 (57.8%) as CFA on excision. All features except for increased stromal cellularity were statistically significant. The average number of histologic features seen in PT and CFA was 3.9 and 1.4, respectively (odds ratio [OR], 7.27; 95% confidence interval [CI], 2.44-21.69; P = .0004). The average number of mitoses per 10 hpf was 3.0 for PT compared with 0.8 for CFA (OR, 2.14; 95% CI, 1.18-3.86; P = .01). The presence of mitoses (three or more) and/or total histologic features of three or more on CNB specimens were the most helpful features in predicting PT on excision. Copyright© by the American Society for Clinical Pathology.

  10. Piezoelectrically Actuated Robotic System for MRI-Guided Prostate Percutaneous Therapy

    Science.gov (United States)

    Su, Hao; Shang, Weijian; Cole, Gregory; Li, Gang; Harrington, Kevin; Camilo, Alexander; Tokuda, Junichi; Tempany, Clare M.; Hata, Nobuhiko; Fischer, Gregory S.

    2014-01-01

    This paper presents a fully-actuated robotic system for percutaneous prostate therapy under continuously acquired live magnetic resonance imaging (MRI) guidance. The system is composed of modular hardware and software to support the surgical workflow of intra-operative MRI-guided surgical procedures. We present the development of a 6-degree-of-freedom (DOF) needle placement robot for transperineal prostate interventions. The robot consists of a 3-DOF needle driver module and a 3-DOF Cartesian motion module. The needle driver provides needle cannula translation and rotation (2-DOF) and stylet translation (1-DOF). A custom robot controller consisting of multiple piezoelectric motor drivers provides precision closed-loop control of piezoelectric motors and enables simultaneous robot motion and MR imaging. The developed modular robot control interface software performs image-based registration, kinematics calculation, and exchanges robot commands and coordinates between the navigation software and the robot controller with a new implementation of the open network communication protocol OpenIGTLink. Comprehensive compatibility of the robot is evaluated inside a 3-Tesla MRI scanner using standard imaging sequences and the signal-to-noise ratio (SNR) loss is limited to 15%. The image deterioration due to the present and motion of robot demonstrates unobservable image interference. Twenty-five targeted needle placements inside gelatin phantoms utilizing an 18-gauge ceramic needle demonstrated 0.87 mm root mean square (RMS) error in 3D Euclidean distance based on MRI volume segmentation of the image-guided robotic needle placement procedure. PMID:26412962

  11. Improving the Prediction of Prostate Cancer Overall Survival by Supplementing Readily Available Clinical Data with Gene Expression Levels of IGFBP3 and F3 in Formalin-Fixed Paraffin Embedded Core Needle Biopsy Material.

    Directory of Open Access Journals (Sweden)

    Zhuochun Peng

    Full Text Available A previously reported expression signature of three genes (IGFBP3, F3 and VGLL3 was shown to have potential prognostic value in estimating overall and cancer-specific survivals at diagnosis of prostate cancer in a pilot cohort study using freshly frozen Fine Needle Aspiration (FNA samples.We carried out a new cohort study with 241 prostate cancer patients diagnosed from 2004-2007 with a follow-up exceeding 6 years in order to verify the prognostic value of gene expression signature in formalin fixed paraffin embedded (FFPE prostate core needle biopsy tissue samples. The cohort consisted of four patient groups with different survival times and death causes. A four multiplex one-step RT-qPCR test kit, designed and optimized for measuring the expression signature in FFPE core needle biopsy samples, was used. In archive FFPE biopsy samples the expression differences of two genes (IGFBP3 and F3 were measured. The survival time predictions using the current clinical parameters only, such as age at diagnosis, Gleason score, PSA value and tumor stage, and clinical parameters supplemented with the expression levels of IGFBP3 and F3, were compared.When combined with currently used clinical parameters, the gene expression levels of IGFBP3 and F3 are improving the prediction of survival time as compared to using clinical parameters alone.The assessment of IGFBP3 and F3 gene expression levels in FFPE prostate cancer tissue would provide an improved survival prediction for prostate cancer patients at the time of diagnosis.

  12. Improved transvenous liver biopsy needle

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Matzen, P; Christoffersen, P

    1979-01-01

    A modified type of the standard transvenous cholangiography biopsy needle is described. The modified tranvenous liver biopsy needle caused only minimal artefactual changes of the liver biopsy specimens. The new type of biopsy needle is a modified Menghini needle. The conventional Menghini needle...... should be avoided for transvenous catheter biopsies because of risk of leaving catheter fragments in the liver....

  13. Accuracy of biopsy needle navigation using the Medarpa system - computed tomography reality superimposed on the site of intervention

    International Nuclear Information System (INIS)

    Khan, M. Fawad; Maataoui, Adel; Gurung, Jessen; Schiemann, Mirko; Vogl, Thomas J.; Dogan, Selami; Ackermann, Hanns; Wesarg, Stefan; Sakas, Georgios

    2005-01-01

    The aim of this work was to determine the accuracy of a new navigational system, Medarpa, with a transparent display superimposing computed tomography (CT) reality on the site of intervention. Medarpa uses an optical and an electromagnetic tracking system which allows tracking of instruments, the radiologist and the transparent display. The display superimposes a CT view of a phantom chest on a phantom chest model, in real time. In group A, needle positioning was performed using the Medarpa system. Three targets (diameter 1.5 mm) located inside the phantom were punctured. In group B, the same targets were used to perform standard CT-guided puncturing using the single-slice technique. The same needles were used in both groups (15 G, 15 cm). A total of 42 punctures were performed in each group. Post puncture, CT scans were made to verify needle tip positions. The mean deviation from the needle tip to the targets was 6.65±1.61 mm for group A (range 3.54-9.51 mm) and 7.05±1.33 mm for group B (range 4.10-9.45 mm). No significant difference was found between group A and group B for any target (p>0.05). No significant difference was found between the targets of the same group (p>0.05). The accuracy in needle puncturing using the augmented reality system, Medarpa, matches the accuracy achieved by CT-guided puncturing technique. (orig.)

  14. Towards real-time cardiovascular magnetic resonance guided transarterial CoreValve implantation: in vivo evaluation in swine

    Science.gov (United States)

    2012-01-01

    Background Real-time cardiovascular magnetic resonance (rtCMR) is considered attractive for guiding TAVI. Owing to an unlimited scan plane orientation and an unsurpassed soft-tissue contrast with simultaneous device visualization, rtCMR is presumed to allow safe device navigation and to offer optimal orientation for precise axial positioning. We sought to evaluate the preclinical feasibility of rtCMR-guided transarterial aortic valve implatation (TAVI) using the nitinol-based Medtronic CoreValve bioprosthesis. Methods rtCMR-guided transfemoral (n = 2) and transsubclavian (n = 6) TAVI was performed in 8 swine using the original CoreValve prosthesis and a modified, CMR-compatible delivery catheter without ferromagnetic components. Results rtCMR using TrueFISP sequences provided reliable imaging guidance during TAVI, which was successful in 6 swine. One transfemoral attempt failed due to unsuccessful aortic arch passage and one pericardial tamponade with subsequent death occurred as a result of ventricular perforation by the device tip due to an operating error, this complication being detected without delay by rtCMR. rtCMR allowed for a detailed, simultaneous visualization of the delivery system with the mounted stent-valve and the surrounding anatomy, resulting in improved visualization during navigation through the vasculature, passage of the aortic valve, and during placement and deployment of the stent-valve. Post-interventional success could be confirmed using ECG-triggered time-resolved cine-TrueFISP and flow-sensitive phase-contrast sequences. Intended valve position was confirmed by ex-vivo histology. Conclusions Our study shows that rtCMR-guided TAVI using the commercial CoreValve prosthesis in conjunction with a modified delivery system is feasible in swine, allowing improved procedural guidance including immediate detection of complications and direct functional assessment with reduction of radiation and omission of contrast media. PMID:22453050

  15. Towards real-time cardiovascular magnetic resonance guided transarterial CoreValve implantation: in vivo evaluation in swine.

    Science.gov (United States)

    Kahlert, Philipp; Parohl, Nina; Albert, Juliane; Schäfer, Lena; Reinhardt, Renate; Kaiser, Gernot M; McDougall, Ian; Decker, Brad; Plicht, Björn; Erbel, Raimund; Eggebrecht, Holger; Ladd, Mark E; Quick, Harald H

    2012-03-27

    Real-time cardiovascular magnetic resonance (rtCMR) is considered attractive for guiding TAVI. Owing to an unlimited scan plane orientation and an unsurpassed soft-tissue contrast with simultaneous device visualization, rtCMR is presumed to allow safe device navigation and to offer optimal orientation for precise axial positioning. We sought to evaluate the preclinical feasibility of rtCMR-guided transarterial aortic valve implatation (TAVI) using the nitinol-based Medtronic CoreValve bioprosthesis. rtCMR-guided transfemoral (n = 2) and transsubclavian (n = 6) TAVI was performed in 8 swine using the original CoreValve prosthesis and a modified, CMR-compatible delivery catheter without ferromagnetic components. rtCMR using TrueFISP sequences provided reliable imaging guidance during TAVI, which was successful in 6 swine. One transfemoral attempt failed due to unsuccessful aortic arch passage and one pericardial tamponade with subsequent death occurred as a result of ventricular perforation by the device tip due to an operating error, this complication being detected without delay by rtCMR. rtCMR allowed for a detailed, simultaneous visualization of the delivery system with the mounted stent-valve and the surrounding anatomy, resulting in improved visualization during navigation through the vasculature, passage of the aortic valve, and during placement and deployment of the stent-valve. Post-interventional success could be confirmed using ECG-triggered time-resolved cine-TrueFISP and flow-sensitive phase-contrast sequences. Intended valve position was confirmed by ex-vivo histology. Our study shows that rtCMR-guided TAVI using the commercial CoreValve prosthesis in conjunction with a modified delivery system is feasible in swine, allowing improved procedural guidance including immediate detection of complications and direct functional assessment with reduction of radiation and omission of contrast media.

  16. Towards real-time cardiovascular magnetic resonance guided transarterial CoreValve implantation: in vivo evaluation in swine

    Directory of Open Access Journals (Sweden)

    Kahlert Philipp

    2012-03-01

    Full Text Available Abstract Background Real-time cardiovascular magnetic resonance (rtCMR is considered attractive for guiding TAVI. Owing to an unlimited scan plane orientation and an unsurpassed soft-tissue contrast with simultaneous device visualization, rtCMR is presumed to allow safe device navigation and to offer optimal orientation for precise axial positioning. We sought to evaluate the preclinical feasibility of rtCMR-guided transarterial aortic valve implatation (TAVI using the nitinol-based Medtronic CoreValve bioprosthesis. Methods rtCMR-guided transfemoral (n = 2 and transsubclavian (n = 6 TAVI was performed in 8 swine using the original CoreValve prosthesis and a modified, CMR-compatible delivery catheter without ferromagnetic components. Results rtCMR using TrueFISP sequences provided reliable imaging guidance during TAVI, which was successful in 6 swine. One transfemoral attempt failed due to unsuccessful aortic arch passage and one pericardial tamponade with subsequent death occurred as a result of ventricular perforation by the device tip due to an operating error, this complication being detected without delay by rtCMR. rtCMR allowed for a detailed, simultaneous visualization of the delivery system with the mounted stent-valve and the surrounding anatomy, resulting in improved visualization during navigation through the vasculature, passage of the aortic valve, and during placement and deployment of the stent-valve. Post-interventional success could be confirmed using ECG-triggered time-resolved cine-TrueFISP and flow-sensitive phase-contrast sequences. Intended valve position was confirmed by ex-vivo histology. Conclusions Our study shows that rtCMR-guided TAVI using the commercial CoreValve prosthesis in conjunction with a modified delivery system is feasible in swine, allowing improved procedural guidance including immediate detection of complications and direct functional assessment with reduction of radiation and omission of contrast media.

  17. The role of ultrasound and ultrasound-guided fine needle aspiration biopsy of lymph nodes in patients with skin tumours

    International Nuclear Information System (INIS)

    Solivetti, Francesco Maria; Elia, Fulvia; Santaguida, Maria Giulia; Guerrisi, Antonino; Visca, Paolo; Cercato, Maria Cecilia; Di Carlo, Aldo

    2014-01-01

    The primary aim of this study was to evaluate the diagnostic accuracy of ultrasound (US) in the study of superficial lymph nodes during the follow-up of patients surgically treated for skin tumours. The secondary objective was to compare positive cytological results with histological reports. From 2004 to 2011, 480 patients (male/female: 285/195; median age 57 years; prevalent skin tumour: melanoma) underwent US-guided fine-needle aspiration biopsy (FNAB) of suspicious recurrent lymph nodes. An expert radiologist first performed US testing of the lymph nodes, expressing either a negative or positive outcome of the test. Subsequently, US-guided FNAB was performed. FNAB positive patients were subjected to lymphadenectomy; the patients who tested negative underwent the follow-up. The size of lymph nodes was ≤ 2 cm in 90% of cases. Out of the 336 (70%) US “positive” patients, 231 (68.8%) were FNAB positives. Out of the 144 (30%) US “negatives”, 132 (91.7%) were FNAB negatives. The sensitivity and specificity of the US were 95% and 55.7%, respectively; the negative predictive value was 91.7% and the positive predictive value was 68.8%. Definitive histological results confirmed FNAB positivity in 97.5% of lymphadenectomies. US is a sensitive method in the evaluation of superficial lymph nodes during the follow-up of patients with skin tumours. High positive predictive value of cytology was confirmed

  18. The value of preoperative ultrasound guided fine-needle aspiration cytology of radiologically suspicious axillary lymph nodes in breast cancer

    Directory of Open Access Journals (Sweden)

    Torill Sauer

    2014-01-01

    Full Text Available Background: Preoperative ultrasound (US and eventually US-guided fine-needle aspiration cytology (FNAC of suspicious axillary lymph nodes (ALN is a standard procedure in the work-up of suspicious breast lesions. Preoperative US FNAC may prevent sentinel node biopsy (SNB procedure in 24-30% of patients with early stage breast carcinoma. The aim of this study was to evaluate the institutional results of this preoperative diagnostic procedure. Materials and Methods: A total of 182 cases of preoperative FNAC of suspicious ALN where retrieved from the pathology files. The results were compared with the final histology and staging. False negative (FN FNAC cases were reviewed and possibly missed metastatic cases (2 were immunostained with the epithelial marker AE1/AE3. Results: There were no false positives, whereas 16 cases were FN. In all but one case the FN′s represented sampling error. Half of the 16 FN cases in this series were macrometastases. Discussion: About 83% of the preoperatively aspirated cases were N+, indicating that a radiologically suspicious ALN has a very high risk of being metastatic. Preoperative US guided FNAC from radiologically suspicious ALN is highly efficient in detecting metastases. Depending on national guidelines, a preoperative, positive ALN FNAC might help to stratify the patients as to SNB and/or ALN dissection.

  19. CT-guided lung biopsy: incidence of pneumothorax after instillation of NaCl into the biopsy track

    International Nuclear Information System (INIS)

    Billich, Christian; Brenner, Gerhard; Schmidt, Stefan A.; Brambs, Hans-Juergen; Pauls, Sandra; Muche, Rainer; Krueger, Stefan

    2008-01-01

    This study was conducted to evaluate whether instillation of NaCl 0.9% solution into the biopsy track reduces the incidence of pneumothoraces after CT-guided lung biopsy. A total of 140 consecutive patients with pulmonary lesions were included in this prospective study. All patients were alternatingly assigned to one of two groups: group A in whom the puncture access was sealed by instillation of NaCl 0.9% solution during extraction of the guide needle (n 70) or group B for whom no sealing was performed (n = 70). CT-guided biopsy was performed with a 18-G coaxial system. Localization of lesion (pleural, peripheral, central), lesion size, needle-pleural angle, rate of pneumothorax and alveolar hemorrhage were evaluated. In group A, the incidence of pneumothorax was lower compared to group B (8%, 6/70 patients vs. 34%, 24/70 patients; P < 0.001). All pneumothoraces occurred directly post punctionem after extraction of the guide needle. One patient in group A and eight patients in group B developed large pneumothoraces requiring chest tube placement (P 0.01). The frequency of pneumothorax was independent of other variables. After CT-guided biopsy, instillation of NaCl 0.9% solution into the puncture access during extraction of the needle significantly reduces the incidence of pneumothorax. (orig.)

  20. CT-guided lung biopsy: incidence of pneumothorax after instillation of NaCl into the biopsy track

    Energy Technology Data Exchange (ETDEWEB)

    Billich, Christian; Brenner, Gerhard; Schmidt, Stefan A.; Brambs, Hans-Juergen; Pauls, Sandra [University of Ulm, Department of Diagnostic and Interventional Radiology, Ulm (Germany); Muche, Rainer [University of Ulm, Institute of Biometrics, Ulm (Germany); Krueger, Stefan [University of Ulm, Department of Internal Medicine, Ulm (Germany)

    2008-06-15

    This study was conducted to evaluate whether instillation of NaCl 0.9% solution into the biopsy track reduces the incidence of pneumothoraces after CT-guided lung biopsy. A total of 140 consecutive patients with pulmonary lesions were included in this prospective study. All patients were alternatingly assigned to one of two groups: group A in whom the puncture access was sealed by instillation of NaCl 0.9% solution during extraction of the guide needle (n = 70) or group B for whom no sealing was performed (n = 70). CT-guided biopsy was performed with a 18-G coaxial system. Localization of lesion (pleural, peripheral, central), lesion size, needle-pleural angle, rate of pneumothorax and alveolar hemorrhage were evaluated. In group A, the incidence of pneumothorax was lower compared to group B (8%, 6/70 patients vs. 34%, 24/70 patients; P < 0.001). All pneumothoraces occurred directly post punctionem after extraction of the guide needle. One patient in group A and eight patients in group B developed large pneumothoraces requiring chest tube placement (P = 0.01). The frequency of pneumothorax was independent of other variables. After CT-guided biopsy, instillation of NaCl 0.9% solution into the puncture access during extraction of the needle significantly reduces the incidence of pneumothorax. (orig.)

  1. Cloned foal derived from in vivo matured horse oocytes aspirated by the short disposable needle system.

    Science.gov (United States)

    Lee, Wonyou; Song, Kilyoung; Lee, Inhyung; Shin, Hyungdo; Lee, Byeong Chun; Yeon, Seongchan; Jang, Goo

    2015-01-01

    Transvaginal ultrasound-guided follicle aspiration is one method of obtaining recipient oocytes for equine somatic cell nuclear transfer (SCNT). This study was conducted: (1) to evaluate the possibility of oocyte aspiration from pre-ovulatory follicles using a short disposable needle system (14-G) by comparing the oocyte recovery rate with that of a long double lumen needle (12-G); (2) to investigate the developmental competence of recovered oocytes after SCNT and embryo transfer. The recovery rates with the short disposable needle vs. the long needle were not significantly different (47.5% and 35.0%, respectively). Twenty-six SCNT embryos were transferred to 13 mares, and one mare delivered a live offspring at Day 342. There was a perfect identity match between the cloned foal and the cell donor after analysis of microsatellite DNA, and the mitochondrial DNA of the cloned foal was identical with that of the oocyte donor. These results demonstrated that the short disposable needle system can be used to recover oocytes to use as cytoplasts for SCNT, in the production of cloned foals and for other applications in equine embryology.

  2. In-bore setup and software for 3T MRI-guided transperineal prostate biopsy

    International Nuclear Information System (INIS)

    Tokuda, Junichi; Tuncali, Kemal; Song, Sang-Eun; Fedorov, Andriy; Oguro, Sota; Fennessy, Fiona M; Tempany, Clare M; Hata, Nobuhiko; Iordachita, Iulian; Lasso, Andras

    2012-01-01

    MRI-guided prostate biopsy in conventional closed-bore scanners requires transferring the patient outside the bore during needle insertion due to the constrained in-bore space, causing a safety hazard and limiting image feedback. To address this issue, we present our custom-made in-bore setup and software to support MRI-guided transperineal prostate biopsy in a wide-bore 3 T MRI scanner. The setup consists of a specially designed tabletop and a needle-guiding template with a Z-frame that gives a physician access to the perineum of the patient at the imaging position and allows the physician to perform MRI-guided transperineal biopsy without moving the patient out of the scanner. The software and Z-frame allow registration of the template, target planning and biopsy guidance. Initially, we performed phantom experiments to assess the accuracy of template registration and needle placement in a controlled environment. Subsequently, we embarked on our clinical trial (N = 10). The phantom experiments showed that the translational errors of the template registration along the right–left (RP) and anterior–posterior (AP) axes were 1.1 ± 0.8 and 1.4 ± 1.1 mm, respectively, while the rotational errors around the RL, AP and superior–inferior axes were (0.8 ± 1.0)°, (1.7 ± 1.6)° and (0.0 ± 0.0)°, respectively. The 2D root-mean-square (RMS) needle-placement error was 3 mm. The clinical biopsy procedures were safely carried out in all ten clinical cases with a needle-placement error of 5.4 mm (2D RMS). In conclusion, transperineal prostate biopsy in a wide-bore 3T scanner is feasible using our custom-made tabletop setup and software, which supports manual needle placement without moving the patient out of the magnet. (paper)

  3. A foreign body reaction to Surgicel® in a lymph node diagnosed by endobronchial ultrasound-guided transbronchial needle aspiration

    Directory of Open Access Journals (Sweden)

    Diana Badenes

    2017-01-01

    Full Text Available Surgicel ® (Ethicon, North Ryde, NSW, Australia is an absorbable sheet of oxidized cellulose polyanhydroglucuronic acid polymer used as an hemostatic in cardiovascular and thoracic surgery. In some cases, the retained material may cause foreign body granulomatous reactions and simulate tumor recurrence, an abscess, an hematoma, or an infection. We report the case of a 55-year-old patient who was operated of a lung adenocarcinoma. In the thoracic computed tomography scan 1 year after the surgery, a right paratracheal lymph node was detected, so endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA was performed suspecting recurrence of the tumor. The cytology results of the lymph node showed a nonnecrotizing granulomatous reaction secondary to Surgicel ® , used as an hemostatic during the surgery. The objective of presenting this case is to consider foreign body reaction to Surgicel ® in the differential diagnosis of postoperative suspicion of neoplastic recurrence, and on the other hand, to note that EBUS-TBNA enables diagnosis.

  4. Surgical treatment for mediastinal abscess induced by endobronchial ultrasound-guided transbronchial needle aspiration: a case report and literature review.

    Science.gov (United States)

    Yokoyama, Yujiro; Nakagomi, Takahiro; Shikata, Daichi; Higuchi, Rumi; Oyama, Toshio; Goto, Taichiro

    2017-07-14

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a useful and less invasive procedure for the definitive diagnosis of mediastinal and hilar lymph nodes. However, infectious complications can occur after EBUS-TBNA, although they are extremely rare. A 66-year-old man with necrotic and swollen lower paratracheal lymph nodes underwent EBUS-TBNA. A mediastinal abscess developed 9 days post-procedure. Surgical drainage and debridement of the abscess were performed along with lymph node biopsy followed by daily washing of the thoracic cavity. Surgical treatment was effective, leading to remission of the abscess. Biopsy revealed that the tumor was squamous cell carcinoma with no radiologically detected cancer elsewhere in the body. Mediastinal lung cancer was thus confirmed. Subsequent chemoradiotherapy led to the remission of the tumor. Mediastinitis after EBUS-TBNA is rare but should be considered, particularly if the target lymph nodes are necrotic. Mediastinitis can lead to serious and rapid deterioration of the patient's condition, for which surgical intervention is the treatment of choice.

  5. Pneumatically Operated MRI-Compatible Needle Placement Robot for Prostate Interventions

    OpenAIRE

    Fischer, Gregory S.; Iordachita, Iulian; Csoma, Csaba; Tokuda, Junichi; Mewes, Philip W.; Tempany, Clare M.; Hata, Nobuhiko; Fichtinger, Gabor

    2008-01-01

    Magnetic Resonance Imaging (MRI) has potential to be a superior medical imaging modality for guiding and monitoring prostatic interventions. The strong magnetic field prevents the use of conventional mechatronics and the confined physical space makes it extremely challenging to access the patient. We have designed a robotic assistant system that overcomes these difficulties and promises safe and reliable intra-prostatic needle placement inside closed high-field MRI scanners. The robot perform...

  6. Riedel thyroiditis: Fine needle aspiration findings of a rare entity.

    Science.gov (United States)

    Weidner, Anna-Sophie; Molina, David; DeSimone, Robert A; Cohen, Marc A; Giorgadze, Tamar; Scognamiglio, Theresa; Hoda, Rana S

    2015-09-01

    Riedel thyroiditis is a rare fibrosing disorder characterized by extension of the fibroinflammatory process beyond the thyroid capsule. Due to the nature of this lesion, fine-needle aspiration often yields scant material and may be interpreted as non-diagnostic. In this report, we describe cytologic features that allow the cytopathologist to favor a diagnosis of Riedel thyroiditis, thereby guiding appropriate further work-up and management. © 2015 Wiley Periodicals, Inc.

  7. Usefulness of ultrasound-guided mammotome biopsy for microcalcification

    Energy Technology Data Exchange (ETDEWEB)

    Kim, You Me [Dankook University Hospital, Seoul (Korea, Republic of); Park, Hee Boong [Park Breast Clinic, Seoul (Korea, Republic of); Ryu, Jin Woo [Cheonan Choongmu Hospital, Cheonan (Korea, Republic of)

    2005-08-15

    To evaluate the usefulness of ultrasound-guided mammotome biopsy for microcalcification and to suggest a new approach for the localization of microcalcifications which are not detected on ultrasound. Twenty-one calcific lesions in 21 women (aged 33-56 years) underwent ultrasound-guided, vacuum-assisted, mammotome biopsy and a mean of 14 specimens per lesion were obtained. Calcification retrieval was defined as identification of calcifications on specimen radiographs. In the 13 cases of calcifications which were not detected on ultrasound imaging, mammotome biopsy was performed after localization of one or two needles at the microcalcifications under mammography-guidance. Radiographs of the specimens and histologic findings were reviewed and scheduled follow-up imaging was performed for evaluation of the complications of biopsy. Ultrasound-guided, vacuum-assisted, mammotome biopsy removed all calcifications in 21 lesions. Eight (38%) lesions showed visible calcification on the ultrasound while 13 (62%) lesions were invisible, which underwent mammotome biopsy after needle localization under mammography-guidance. Surgery revealed DCIS in 1 (4.8%) of 21 lesions, infiltrating ductal carcinoma in two (9.5%), fibroadenomas with calcifications in 6 (28.6%), fibroadenmas with adenosis in 2(9.5%), and fibrocystic change with calcifications in 10 (47.6%). Clinical significant complications did not occur on follow-up examination in any of the cases. Ultrasound-guided, vacuum-assisted, mammotome biopsy was an effective method for microcalcifications on mammogram. The results suggested that mammotome biopsy after mammogram-guided, needle localization is a good alternative method for the diagnosis of microcalcifications which are undetectable in the ultrasound images.

  8. Usefulness of ultrasound-guided mammotome biopsy for microcalcification

    International Nuclear Information System (INIS)

    Kim, You Me; Park, Hee Boong; Ryu, Jin Woo

    2005-01-01

    To evaluate the usefulness of ultrasound-guided mammotome biopsy for microcalcification and to suggest a new approach for the localization of microcalcifications which are not detected on ultrasound. Twenty-one calcific lesions in 21 women (aged 33-56 years) underwent ultrasound-guided, vacuum-assisted, mammotome biopsy and a mean of 14 specimens per lesion were obtained. Calcification retrieval was defined as identification of calcifications on specimen radiographs. In the 13 cases of calcifications which were not detected on ultrasound imaging, mammotome biopsy was performed after localization of one or two needles at the microcalcifications under mammography-guidance. Radiographs of the specimens and histologic findings were reviewed and scheduled follow-up imaging was performed for evaluation of the complications of biopsy. Ultrasound-guided, vacuum-assisted, mammotome biopsy removed all calcifications in 21 lesions. Eight (38%) lesions showed visible calcification on the ultrasound while 13 (62%) lesions were invisible, which underwent mammotome biopsy after needle localization under mammography-guidance. Surgery revealed DCIS in 1 (4.8%) of 21 lesions, infiltrating ductal carcinoma in two (9.5%), fibroadenomas with calcifications in 6 (28.6%), fibroadenmas with adenosis in 2(9.5%), and fibrocystic change with calcifications in 10 (47.6%). Clinical significant complications did not occur on follow-up examination in any of the cases. Ultrasound-guided, vacuum-assisted, mammotome biopsy was an effective method for microcalcifications on mammogram. The results suggested that mammotome biopsy after mammogram-guided, needle localization is a good alternative method for the diagnosis of microcalcifications which are undetectable in the ultrasound images

  9. Percutaneous Management of Accidentally Retained Foreign Bodies During Image-Guided Non-vascular Procedures: Novel Technique Using a Large-Bore Biopsy System

    Energy Technology Data Exchange (ETDEWEB)

    Cazzato, Roberto Luigi, E-mail: gigicazzato@hotmail.it; Garnon, Julien, E-mail: juleiengarnon@gmail.com [Hôpitaux Universitaires de Strasbourg, HUS, Department of Interventional Radiology, Nouvel Hôpital Civil (France); Ramamurthy, Nitin, E-mail: nitin-ramamurthy@hotmail.com [Norfolk and Norwich University Hospital, Department of Radiology (United Kingdom); Tsoumakidou, Georgia, E-mail: georgia.tsoumakidou@chru-strasbourg.fr; Caudrelier, Jean, E-mail: jean.caudrelier@chru-strasbourg.fr; Thénint, Marie-Aude, E-mail: marie-aude.thenint@chru-strasbourg.fr; Rao, Pramod, E-mail: pramodrao@me.com; Koch, Guillaume, E-mail: guillaume.koch@chru-strasbourg.fr; Gangi, Afshin, E-mail: gangi@unistra.fr [Hôpitaux Universitaires de Strasbourg, HUS, Department of Interventional Radiology, Nouvel Hôpital Civil (France)

    2016-07-15

    ObjectiveTo describe a novel percutaneous image-guided technique using a large-bore biopsy system to retrieve foreign bodies (FBs) accidentally retained during non-vascular interventional procedures.Materials and MethodsBetween May 2013 and October 2015, five patients underwent percutaneous retrieval of five iatrogenic FBs, including a biopsy needle tip in the femoral head following osteoblastoma biopsy and radiofrequency ablation (RFA); a co-axial needle shaft within a giant desmoid tumour following cryoablation; and three post-vertebroplasty cement tails within paraspinal muscles. All FBs were retrieved immediately following original procedures under local or general anaesthesia, using combined computed tomography (CT) and fluoroscopic guidance. The basic technique involved positioning a 6G trocar sleeve around the FB long axis and co-axially advancing an 8G biopsy needle to retrieve the FB within the biopsy core. Retrospective chart review facilitated analysis of procedures, FBs, technical success, and complications.ResultsMean FB size was 23 mm (range 8–74 mm). Four FBs were located within 10 mm of non-vascular significant anatomic structures. The basic technique was successful in 3 cases; 2 cases required technical modifications including using a stiff guide-wire to facilitate retrieval in the case of the post-cryoablation FB; and using the central mandrin of the 6G trocar to push a cement tract back into an augmented vertebra when initial retrieval failed. Overall technical success (FB retrieval or removal to non-hazardous location) was 100 %, with no complications.ConclusionPercutaneous image-guided retrieval of iatrogenic FBs using a large-bore biopsy system is a feasible, safe, effective, and versatile technique, with potential advantages over existing methods.

  10. Ultrasound-guided radiofrequency neurotomy in cervical spine: sonoanatomic study of a new technique in cadavers

    International Nuclear Information System (INIS)

    Lee, S.-H.; Kang, C.H.; Lee, S.-H.; Derby, R.; Yang, S.N.; Lee, J.E.; Kim, J.H.; Kim, S.S.; Lee, J.-H.

    2008-01-01

    Aim: To develop an ultrasound-guided technique for radiofrequency (RF) cervical medial branch neurotomy and to validate the accuracy of this new method. Materials and methods: Five non-embalmed, fresh cadavers were used; three male and two female cadavers with a median age at death of 67.2 years (range 50-84 years). This study was conducted in two parts. First, two of the cadavers were used to define the sonographic target point for RF cervical medial branch neurotomy using high-resolution ultrasound (12 to 5 MHz). The needles were guided to five consecutive cervical medial branches in the cadavers under ultrasound guidance. Subsequently, the position of the ultrasound-guided needle was verified using C-arm fluoroscopy. Ultrasound-guided RF neurotomy was performed to the C5 medial branches in all five cadavers. In the three cadavers not used in the first part of the study, ultrasound-guided RF neurotomy without C-arm fluoroscopic confirmation was performed to the C3-C7 medial branches. The accuracy of neurotomy was assessed by pathological examination of the cervical medial branches obtained through cadaver dissection. Results: In all five cadavers, the sonographic target point was identified in all C3-C7 segments with the 12 to 5 MHz linear transducer. In all 20 needle placements for the first and second cadavers, C-arm fluoroscopy validated proper needle tip positions. In all five cadavers, successful neurotomy was pathologically confirmed in 30 of 34 cervical medial branches. Conclusions: Ultrasound-guided cervical medial branch neurotomy was successfully performed in 30 of 34 cervical medial branches in five cadavers. However, before eliminating fluoroscopic validation of final needle tip positioning, the technique should be validated in symptomatic patients

  11. Diagnostic Value of ERG in Prostate Needle Biopsies Containing Minute Cancer Foci

    Directory of Open Access Journals (Sweden)

    Bachurska Svitlana Y.

    2017-03-01

    Full Text Available Background: Prostate carcinoma (PC is the second most diagnosed cancer in men population worldwide. The small amount of the tissue in prostate needle biopsy is often sufficient for the correct interpretation. Novel antibodies, as ERG, could add to the diagnostic value of IHC study in analysing difficult core biopsies.

  12. MR-guided lumbar sympathicolysis

    Energy Technology Data Exchange (ETDEWEB)

    Koenig, Claudius W.; Schott, Ulrich G.; Pereira, Philippe L.; Truebenbach, Jochen; Claussen, Claus D.; Duda, Stephan H. [Department of Diagnostic Radiology, University of Tuebingen (Germany); Schneider, Wilke [Department of Vascular Surgery, University of Tuebingen (Germany)

    2002-06-01

    The aim of this study was to demonstrate the feasibility of MR-guided lumbar sympathicolysis (LSL) in a non-selected patient population. One hundred one MR-guided LSL procedures were performed in 89 patients according to Haaga's technique using a horizontally open clinical MR system (0.2 T) and non-ferromagnetic 20-G cannulas (neurolysis, n=93; blockade, n=8). Only gradient-recalled sequences in either single or multislice mode [fast imaging with steady-state precession (FISP) and fast low-angle shot] were applied for anatomical survey and needle guiding. Bupivacaine injection was monitored with MR fluoroscopically. Fluid distribution was subsequently documented in a CT scan in 65 patients. Ninety-one LSL procedures could be successfully completed. Ten patients were not treated using MR due to patient inconvenience, severe motion artifacts (n=4 each), excessive spondylophytes, and retroperitoneal hematoma (n=1 each). One case of ureteral necrosis occurred. Motion artifacts were rated less severe in single-slice FISP sequences and in obese patients. An average of 3.48 sequence measurements were required for definitive needle placement. Average table time was 32.3 min. An MR-guided LSL is feasible and can be performed with acceptable safety and time effort. It can be recommended for repeated sympathetic blockades in younger patients to avoid cumulative irradiation associated with CT guidance. (orig.)

  13. MR-guided lumbar sympathicolysis

    International Nuclear Information System (INIS)

    Koenig, Claudius W.; Schott, Ulrich G.; Pereira, Philippe L.; Truebenbach, Jochen; Claussen, Claus D.; Duda, Stephan H.; Schneider, Wilke

    2002-01-01

    The aim of this study was to demonstrate the feasibility of MR-guided lumbar sympathicolysis (LSL) in a non-selected patient population. One hundred one MR-guided LSL procedures were performed in 89 patients according to Haaga's technique using a horizontally open clinical MR system (0.2 T) and non-ferromagnetic 20-G cannulas (neurolysis, n=93; blockade, n=8). Only gradient-recalled sequences in either single or multislice mode [fast imaging with steady-state precession (FISP) and fast low-angle shot] were applied for anatomical survey and needle guiding. Bupivacaine injection was monitored with MR fluoroscopically. Fluid distribution was subsequently documented in a CT scan in 65 patients. Ninety-one LSL procedures could be successfully completed. Ten patients were not treated using MR due to patient inconvenience, severe motion artifacts (n=4 each), excessive spondylophytes, and retroperitoneal hematoma (n=1 each). One case of ureteral necrosis occurred. Motion artifacts were rated less severe in single-slice FISP sequences and in obese patients. An average of 3.48 sequence measurements were required for definitive needle placement. Average table time was 32.3 min. An MR-guided LSL is feasible and can be performed with acceptable safety and time effort. It can be recommended for repeated sympathetic blockades in younger patients to avoid cumulative irradiation associated with CT guidance. (orig.)

  14. Breast cancer: determining the genetic profile from ultrasound-guided percutaneous biopsy specimens obtained during the diagnostic workups.

    Science.gov (United States)

    López Ruiz, J A; Zabalza Estévez, I; Mieza Arana, J A

    2016-01-01

    To evaluate the possibility of determining the genetic profile of primary malignant tumors of the breast from specimens obtained by ultrasound-guided percutaneous biopsies during the diagnostic imaging workup. This is a retrospective study in 13 consecutive patients diagnosed with invasive breast cancer by B-mode ultrasound-guided 12 G core needle biopsy. After clinical indication, the pathologist decided whether the paraffin block specimens seemed suitable (on the basis of tumor size, validity of the sample, and percentage of tumor cells) before sending them for genetic analysis with the MammaPrint® platform. The size of the tumors on ultrasound ranged from 0.6cm to 5cm. In 11 patients the preserved specimen was considered valid and suitable for use in determining the genetic profile. In 1 patient (with a 1cm tumor) the pathologist decided that it was necessary to repeat the core biopsy to obtain additional samples. In 1 patient (with a 5cm tumor) the specimen was not considered valid by the genetic laboratory. The percentage of tumor cells in the samples ranged from 60% to 70%. In 11/13 cases (84.62%) it was possible to do the genetic analysis on the previously diagnosed samples. In most cases, regardless of tumor size, it is possible to obtain the genetic profile from tissue specimens obtained with ultrasound-guided 12 G core biopsy preserved in paraffin blocks. Copyright © 2015 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  15. ULTRASONOGRAPHY AND COMPUTED TOMOGRAPHY GUIDED FINE NEEDLE ASPIRATION CYTOLOGY IN DIAGNOSING INTRA-ABDOMINAL LESIONS- A 6-YEAR RETROSPECTIVE STUDY IN A TERTIARY CARE HOSPITAL IN MANIPUR

    Directory of Open Access Journals (Sweden)

    Ratan Konjengbam

    2017-07-01

    Full Text Available BACKGROUND Fine-Needle Aspiration Cytology (FNAC is a widely used method, which is accurate and safe in a readily palpable masses. But, in those inaccessible lesions and deeper organs are safely aspirated using fine needle radiological procedure like ultrasound or computed tomography guided. The aim of the study is to assess the utility of FNAC in the diagnosis of intra-abdominal lesions and different pattern of lesions in particular to the sites. MATERIALS AND METHODS This retrospective study was done in the Department of Pathology, Regional Institute of Medical Sciences (RIMS, Imphal, between June 2010 and June 2016. The study included 128 intra-abdominal masses. Giemsa and Papanicolaou’s stains were used. The cytological diagnosis was correlated with clinical and radiological data to arrive at a final diagnosis. RESULTS Reports on FNAC smears were retrospectively analysed, which had been done in various anatomic sites- liver (70 cases, colon (19 cases, gallbladder (17 cases, mesenteric lymph nodes (12 cases, ovary (3 cases, adrenals (2 cases and 1 case each of pancreas, peritoneal wall, pelvic, suprapubic and flank masses. The mean age was 42.16 years with M:F of 1.3:1. The diagnostic yield was 85.2% in combination for Ultrasound Guided (USG and Computed Tomography (CT guided aspiration. The smears were classified as benign neoplastic, malignant neoplastic, non-neoplastic, inconclusive and unsatisfactory for interpretation. There were 79 (61.7% malignant neoplastic lesion, 5 (3.9% benign neoplastic lesion, 25 (19.5% non-neoplastic lesion, one (0.7% inconclusive lesions and 18 (14.1% unsatisfactory smears. The liver and the colon were the most common sites. Adenocarcinomas and Hepatocellular Carcinoma (HCC were the most common malignant lesions comprising of 35 (44.3% and 25 (31.6% of the total malignant lesions diagnosed. CONCLUSION Intra-abdominal FNA is a simple, economical and a safe procedure with high sensitivity, specificity and

  16. Ultrasound-guided diagnostic breast biopsy methodology: retrospective comparison of the 8-gauge vacuum-assisted biopsy approach versus the spring-loaded 14-gauge core biopsy approach

    Science.gov (United States)

    2011-01-01

    Background Ultrasound-guided diagnostic breast biopsy technology represents the current standard of care for the evaluation of indeterminate and suspicious lesions seen on diagnostic breast ultrasound. Yet, there remains much debate as to which particular method of ultrasound-guided diagnostic breast biopsy provides the most accurate and optimal diagnostic information. The aim of the current study was to compare and contrast the 8-gauge vacuum-assisted biopsy approach and the spring-loaded 14-gauge core biopsy approach. Methods A retrospective analysis was done of all ultrasound-guided diagnostic breast biopsy procedures performed by either the 8-gauge vacuum-assisted biopsy approach or the spring-loaded 14-gauge core biopsy approach by a single surgeon from July 2001 through June 2009. Results Among 1443 ultrasound-guided diagnostic breast biopsy procedures performed, 724 (50.2%) were by the 8-gauge vacuum-assisted biopsy technique and 719 (49.8%) were by the spring-loaded 14-gauge core biopsy technique. The total number of false negative cases (i.e., benign findings instead of invasive breast carcinoma) was significantly greater (P = 0.008) in the spring-loaded 14-gauge core biopsy group (8/681, 1.2%) as compared to in the 8-gauge vacuum-assisted biopsy group (0/652, 0%), with an overall false negative rate of 2.1% (8/386) for the spring-loaded 14-gauge core biopsy group as compared to 0% (0/148) for the 8-gauge vacuum-assisted biopsy group. Significantly more (P guided diagnostic breast biopsy procedure. Significantly more (P guided diagnostic breast biopsy procedure. Conclusions In appropriately selected cases, the 8-gauge vacuum-assisted biopsy approach appears to be advantageous to the spring-loaded 14-gauge core biopsy approach for providing the most accurate and optimal diagnostic information. PMID:21835024

  17. Fine-needle trucut biopsy versus fine-needle aspiration cytology with ultrasound guidance in the abdomen

    International Nuclear Information System (INIS)

    O'Connell, A.M.; Keeling, F.; Given, M.; Logan, M.; Lee, M.J.

    2008-01-01

    Historically, fine-needle aspiration cytology (FNAC) has varying sensitivity, specificity and accuracy in the diagnosis of abdominal lesions with a high insufficient sampling rate. We compared 20-G fine-needle trucut biopsy (FNTB) with FNAC results in the biopsy of solid abdominal tumours. A retrospective review of 171 (128x 20-G FNTB and 43x FNAC) ultrasound-guided biopsies of abdominal tumours on 157 patients (male : female 85:72, mean age 61.25 years) were carried out. One hundred and seventy-one biopsies were carried out: liver 109, pancreas 19, lumph node 10, omentum 5, right iliac fossa mass 6, adrenal 6 and others 16. An average of 2.06 and 1.97 passes (range 1-4) were carried out per FNTB and FNAC, respectively. A definitive diagnosis was made in 122/128 biopsies (95.3%) and 32/43 biopsies (74.4%) for FNTB and FNAC, respectively. Diagnoses consisted of metastatic liver disease (74/171), pancreatic adenocarcinoma (10/171), lymphoma (8/171) and others (33/171) and benign (29/171). No significant complications occurred in either group. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 87, 100, 100, 50, 84.4 and 93.1, 100, 100, 60, 71.4 for FNTB and FNAC, respectively. A greater and more consistent positive diagnosis rate is yielded by 20-G FNTB (95.3%) that FNAC (74.4%). The diagnostic accuracy of FNTB is 84.4% cmopared with 69.8% for FNAC. A greater insufficient sampling rate occurs with FNAC (25.6%) than with FNTB (4.7%). For abdominal biopsy, 20-G FNTB needles have a much higher yield than FNAC with no increase in complications. FNTB is the preferred choice, particularly where cytological assistance at the time of biopsy is unavailable.

  18. A non-freaked out guide to teaching the common core using the 32 literacy anchor standards to develop college- and career-ready students

    CERN Document Server

    Stuart, Dave

    2014-01-01

    Implement the Common Core for ELA without all the stress A Non-Freaked Out Guide to Teaching the Common Core uses the often-neglected anchor standards to get to the heart of the Common Core State Standards (CCSS)-teaching students the skills they need to be college and career ready. Each anchor standard is broken down into its key points, and a discussion of each anchor standard''s central purpose helps outline the context for each required skill. This easy-to-read guide gives educators the kind of clear explanations, examples, and strategies they need to feel comfortable teaching the CCSS, an

  19. Dynamics of translational friction in needle-tissue interaction during needle insertion.

    Science.gov (United States)

    Asadian, Ali; Patel, Rajni V; Kermani, Mehrdad R

    2014-01-01

    In this study, a distributed approach to account for dynamic friction during needle insertion in soft tissue is presented. As is well known, friction is a complex nonlinear phenomenon. It appears that classical or static models are unable to capture some of the observations made in systems subjected to significant frictional effects. In needle insertion, translational friction would be a matter of importance when the needle is very flexible, or a stop-and-rotate motion profile at low insertion velocities is implemented, and thus, the system is repeatedly transitioned from a pre-sliding to a sliding mode and vice versa. In order to characterize friction components, a distributed version of the LuGre model in the state-space representation is adopted. This method also facilitates estimating cutting force in an intra-operative manner. To evaluate the performance of the proposed family of friction models, experiments were conducted on homogeneous artificial phantoms and animal tissue. The results illustrate that our approach enables us to represent the main features of friction which is a major force component in needle-tissue interaction during needle-based interventions.

  20. MR-guided preoperative localization and percutaneous core biopsy of suspicious breast lesions - experience on the vertically open 0.5 T system; MRT-gestuetzte Markierung und Stanzbiopsie suspekter Mammalaesionen. Moeglichkeiten und Erfahrungen an einem vertikal offenen 0,5-T-System

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, J.P.; Schulz, T.; Rueger, S.; Schmidt, F.; Kahn, T. [Universitaetsklinikum Leipzig (Germany). Klinik und Poliklinik fuer Diagnostische Radiologie; Horn, L.C. [Inst. fuer Pathologie, Universitaetsklinikum Leipzig (Germany); Leinung, S. [Chirurgische Klinik I, Universitaetsklinikum Leipzig (Germany); Briest, S. [Frauenklinik, Universitaetsklinikum Leipzig (Germany)

    2002-01-01

    Purpose. To evaluate the feasibility of performing breast interventions in a vertically open 0.5 T MR system (SIGNA SP/i, GE Medical Systems). To develop fitted equipment and to establish preoperative wire localization and percutaneous breast core biopsy as clinical routine procedures. Patients and methods. Initially, we applied a localization method with the patient placed in a sitting position in 31 cases using a single loop coil and a self-developed fixation device. Subsequently, 46 wire localizations and 28 percutaneous core biopsies were carried out in prone patient position using an open breast coil with an integrated biopsy device. The used instruments were either MR-compatible (18 G biopsy needle and localization wire, 14 G coaxial needle, prototype of a 16 G double-shoot gun) or MR-safe (double-shoot gun with 16 G needle). Results. After biopsy we found the needle tip (18 G for a wire localization and 14 G for a percutaneous core biopsy, respectively) placed either within or close to the lesions (<10 mm distance) for all patients. Out of a total of 66 benign lesions and 39 malignant tumors we missed the lesion (12 mm mean diameter, 4-25 mm range) during open biopsy in two cases and obtained a false negative result for one percutaneous biopsy of a 5 mm lesion. Conclusion. Preoperative wire localization and percutaneous core biopsy of suspicious breast lesions demonstrated by MRI can be carried out in a vertically open 0.5 T MR scanner. The degree of accuracy is comparable with that of X-ray or ultrasound-guided procedures. A follow-up has to be performed in cases with a negative biopsy. (orig.) [German] Zielsetzung. In den letzten Jahren wurde eine Vielzahl von Systemen zur praeoperativen Markierung oder Biopsie MRT-suspekter Mammalaesionen vorgestellt. Ziel unserer Untersuchungen war es, Moeglichkeiten solcher Verfahren an einem vertikal offenen 0,5-T-Magneten (SIGNA SP/i, GE Medical Systems) zu entwickeln, zu erproben und in die klinische Routine zu

  1. Transcription through the eye of a needle: daily and annual cyclic gene expression variation in Douglas-fir needles.

    Science.gov (United States)

    Cronn, Richard; Dolan, Peter C; Jogdeo, Sanjuro; Wegrzyn, Jill L; Neale, David B; St Clair, J Bradley; Denver, Dee R

    2017-07-24

    Perennial growth in plants is the product of interdependent cycles of daily and annual stimuli that induce cycles of growth and dormancy. In conifers, needles are the key perennial organ that integrates daily and seasonal signals from light, temperature, and water availability. To understand the relationship between seasonal cycles and seasonal gene expression responses in conifers, we examined diurnal and circannual needle mRNA accumulation in Douglas-fir (Pseudotsuga menziesii) needles at diurnal and circannual scales. Using mRNA sequencing, we sampled 6.1 × 10 9 reads from 19 trees and constructed a de novo pan-transcriptome reference that includes 173,882 tree-derived transcripts. Using this reference, we mapped RNA-Seq reads from 179 samples that capture daily and annual variation. We identified 12,042 diurnally-cyclic transcripts, 9299 of which showed homology to annotated genes from other plant genomes, including angiosperm core clock genes. Annual analysis revealed 21,225 circannual transcripts, 17,335 of which showed homology to annotated genes from other plant genomes. The timing of maximum gene expression is associated with light intensity at diurnal scales and photoperiod at annual scales, with approximately half of transcripts reaching maximum expression +/- 2 h from sunrise and sunset, and +/- 20 days from winter and summer solstices. Comparisons with published studies from other conifers shows congruent behavior in clock genes with Japanese cedar (Cryptomeria), and a significant preservation of gene expression patterns for 2278 putative orthologs from Douglas-fir during the summer growing season, and 760 putative orthologs from spruce (Picea) during the transition from fall to winter. Our study highlight the extensive diurnal and circannual transcriptome variability demonstrated in conifer needles. At these temporal scales, 29% of expressed transcripts show a significant diurnal cycle, and 58.7% show a significant circannual cycle. Remarkably

  2. Indications, results, and clinical impact of endoscopic ultrasound (EUS)-guided sampling in gastroenterology

    DEFF Research Database (Denmark)

    Dumonceau, J-M; Polkowski, M; Larghi, A

    2011-01-01

    This article is part of a combined publication that expresses the current view of the European Society of Gastrointestinal Endoscopy (ESGE) about endoscopic ultrasound (EUS)-guided sampling in gastroenterology, including EUS-guided fine needle aspiration (EUS-FNA) and EUS-guided trucut biopsy (EU...

  3. Needle phobia during pregnancy.

    Science.gov (United States)

    Searing, Kimberly; Baukus, Mary; Stark, Mary Ann; Morin, Karen H; Rudell, Barb

    2006-01-01

    The objective of this study was to understand the experience of a pregnant woman with needle phobia and examine its impact on her antepartum, intrapartum, and postpartum experience. A case study format was employed. A 21-year-old primiparous woman with diagnosed needle phobia was interviewed, and her prenatal and delivery records were reviewed. Three tasks during pregnancy were identified: seeking trusting relationships with health care providers; establishing and maintaining control and understanding; and coping with fear of needles, pain, and invasion. As frequent caregivers during childbearing, nurses with an understanding of needle phobia can help to establish trusting relationships with women with this phobia and support them and their families during childbearing and their encounters with needles. (c) 2006, AWHONN, the Association of Women's Health, Obstetric and Neonatal Nurses

  4. Annals of African Medicine - Vol 10, No 2 (2011)

    African Journals Online (AJOL)

    Secondhand smoke exposure among non smoking adults in two Nigerian cities · EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT ... Ultrasound guided percutaneous fine needle aspiration biopsy/automated needle core biopsy of abdominal lesions: Effect on management and cost effectiveness · EMAIL FREE FULL ...

  5. [Deep needling and shallow needling at three acupoints around ear for subjective tinnitus: a randomized controlled trial].

    Science.gov (United States)

    Yin, Tao; Ni, Jinxia; Zhu, Wenzeng

    2015-10-01

    To compare the effective differences between deep needling and shallow needling at three acupoints around ear for subjective tinnitus. Fifty patients with subjective tinnitus were randomized divided into a deep needling group and a shallow needling group, 25 cases in each group. Twenty-two patients in the deep needling group and 20 patients in the shallow needling group were brought into statistic in the end. In the two groups, the three acupoints around ear and distal acupoints were both selected. The acupoints of the affected side such as Yifeng (TE 17), Tinghui (GB 2), Ermen (TE 21), Zhigou (TE 6), Zhongzhu (TE 3) and Hegu (LI 4) were adopted. Yifeng (TE 17), Tinghui (GB 2) and Ermen (TE 21) were acupunctured 30-38 mm in the deep needling group and 15-20 mm in the shallow needling group. The other acupoints were conventionally acupunctured in the two groups. The needles were retained for 30 min,once a day and five times a week for all patients. The treatment was continuously for 4 weeks in the two groups. Tinnitus handicap inventory (THI) scores, tinnitus grades and visual analogue scale (VAS) for tinnitus sound levels were observed before and after treatment, and the effects of the two groups were compared. The total effective rate in the deep needling group was 59.1% (13/22), and it was better than 20.0% (4/20) in the shallow needling group (P deep needling, group, the THI score, tinnitus grade and the VAS score were improved than those before treatment (all P shallow needling group, the three above indices before and after treatment were not different in statistical significance (all P > 0.05). After treatment, all the three indices in the deep needling group were superior to those in the shallow needling group (all P shallow needling at the three acupoints.

  6. Image-guided pleural biopsy: diagnostic yield and complications

    International Nuclear Information System (INIS)

    Benamore, R.E.; Scott, K.; Richards, C.J.; Entwisle, J.J.

    2006-01-01

    Background: Pleural biopsy and cytology are standard procedures for the investigation of pleural disease. Recent medical literature has suggested that image-guided pleural biopsy shows improved sensitivity for the diagnosis of pleural malignancy, when compared with the more commonly performed reverse bevel needle biopsy such as Abrams' needle. In our centre there has been an increasing trend towards performing image-guided pleural biopsies, and to our knowledge there is no large published series documenting the complication rate and diagnostic yield. Methods: The radiology and pathology databases were searched for all image-guided [computed tomography (CT) and ultrasound (US)] pleural biopsies from January 2001 to December 2004. All imaging and histology were reviewed, and final diagnostic information about patients was obtained from the respiratory multidisciplinary team database and patient notes. A record was made of complications following biopsy, presence of pleura in the biopsy, and adequacy of tissue for histological diagnosis. Results: A total of 82 patients underwent 85 image-guided pleural biopsies over a 4-year period. 80 cases were performed under CT and five under US guidance. The rate of new pneumothorax detected by chest radiography was 4.7%. No patient required a chest drain or blood transfusion to treat complications. In 10 (12%) cases, there was inadequate tissue to reach a confident histological diagnosis and in eight (9%) of these, no pleura was present. Assuming all suspicious and inadequate biopsies are treated as benign, which is the worst case scenario, image-guided pleural biopsy has a sensitivity and specificity of 76% and 100%, respectively, for the diagnosis of malignant disease. Conclusions: Image-guided pleural biopsy is a safe procedure with few associated complications and has a higher sensitivity than previously published series for reverse cutting needle biopsy in the diagnosis of malignant pleural disease

  7. Image-guided pleural biopsy: diagnostic yield and complications

    Energy Technology Data Exchange (ETDEWEB)

    Benamore, R.E. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom)]. E-mail: rachelbenamore@doctors.org.uk; Scott, K. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom); Richards, C.J. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom); Entwisle, J.J. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom)

    2006-08-15

    Background: Pleural biopsy and cytology are standard procedures for the investigation of pleural disease. Recent medical literature has suggested that image-guided pleural biopsy shows improved sensitivity for the diagnosis of pleural malignancy, when compared with the more commonly performed reverse bevel needle biopsy such as Abrams' needle. In our centre there has been an increasing trend towards performing image-guided pleural biopsies, and to our knowledge there is no large published series documenting the complication rate and diagnostic yield. Methods: The radiology and pathology databases were searched for all image-guided [computed tomography (CT) and ultrasound (US)] pleural biopsies from January 2001 to December 2004. All imaging and histology were reviewed, and final diagnostic information about patients was obtained from the respiratory multidisciplinary team database and patient notes. A record was made of complications following biopsy, presence of pleura in the biopsy, and adequacy of tissue for histological diagnosis. Results: A total of 82 patients underwent 85 image-guided pleural biopsies over a 4-year period. 80 cases were performed under CT and five under US guidance. The rate of new pneumothorax detected by chest radiography was 4.7%. No patient required a chest drain or blood transfusion to treat complications. In 10 (12%) cases, there was inadequate tissue to reach a confident histological diagnosis and in eight (9%) of these, no pleura was present. Assuming all suspicious and inadequate biopsies are treated as benign, which is the worst case scenario, image-guided pleural biopsy has a sensitivity and specificity of 76% and 100%, respectively, for the diagnosis of malignant disease. Conclusions: Image-guided pleural biopsy is a safe procedure with few associated complications and has a higher sensitivity than previously published series for reverse cutting needle biopsy in the diagnosis of malignant pleural disease.

  8. CT Guided biopsies of musculoskeletal lesions, radiological and pathologic correlation

    International Nuclear Information System (INIS)

    Hadzihasanovic, B.; Milisic, L.; Zuban, J.; Mujic, E.; Jahic, E.; Gjikolli, B.; Hasanovic, B.; Lincender-Cvijetic, L.; Jaganjac, S.

    2006-01-01

    Full text: The aim of the study is to overview our experiences in taking the CT guided biopsies of musculoskeletal lesions during the period of sixteen months, analysis of validity of samples taken and correlation with pathological findings. CT guided biopsies of musculoskeletal lesions were performed in 32 patients during the period of sixteen months (from December 2004 until March 2006). Age range was from 13 to 78 years. Majorities of the biopsies were performed with coaxial cutting needle system (14 G and 16 G) with introducers size 13 and 15 G. Bone biopsies were performed with Yamsidi needles in purpose of taking the bone cylinder. Majorities of the biopsies were performed under local anaesthesia except a thirteen years old child to whom CT guided biopsy of corpus Th 6 was performed under general anaesthesia. Two samples of tissues were sent in formalin solutions to Pathology Institute for pathological verification. In one case of musculoskeletal lesions CT guided biopsies didn't yield a representative tissue sample. We had high level of congruence between radiological and pathological findings; precise presented in the article. CT guided biopsies of musculoskeletal lesions are method of choice for pathologic verification of musculoskeletal lesions proving incomparable less risk compared to 'open' biopsy which requires operating theatre and general anaesthesia. Coaxial needle systems has shown as suitable for yielding representative tissue samples (two samples for each patient), and samples are also appropriate for immunohistochemical analysis

  9. Usefulness of transrectal ultrasound-guided 12 core biopsy method in patients with clinically suspected prostate cancer

    International Nuclear Information System (INIS)

    Kwon, Se Hwan; Lim, Joo Won; Park, Seong Jin; Ko, Young Tae; Kim, Yoon Wha

    2000-01-01

    To evaluate the improvement of prostate cancer detection provided by transrectal ultrasound (TRUS)-guided 12 core biopsy method compared with sextant biopsy method. Between June 1997 and February 1999, 29 patients with pathologically proven prostate cancer in 124 patients who underwent TRUS-guided 12 core biopsy method were evaluated. They had abnormal findings in prostate specific antigen (PSA), digital rectal examination (DRE) or TRUS findings. The prostate was diffusely enlarged in all patients on DRE findings and in 15 cases (15/29, 52%), hard nodule was palpated. The average of PSA and prostate specific antigen density (PSAD) is 229.33 ng/ml (1-2280) and 9.14 ng/ml/cm 3 (0.048-142.5), respectively, 12 transrectal biopsy, including 2 transition zones, was performed in both lobe, 6 biopsies were located in both base, middle and apex. Then 2 biopsies were inserted between 3 biopsies in both peripheral zone and 2 biopsies were performed in both transition zone. Each specimen was pathologically examined. The results of pathology were compared with method 1 and 2, respectively. We defined the method 1 and 2 as different sextant biopsy method. The method 1 is that cores are taken from both base, middle and apex and method 2 is that cores are taken from both base, apex and transition zone. TRUS findings were analyzed by two radiologists. Of the 29 patients with prostate cancer, 3 (10%) had carcinomas only in the additional regions as compared with method. When compared with method 2,2 (7.0%) had carcinomas only in the additional regions. 2 patients were same in both cases. TRUS findings were abnormal in 21 cases in all patients whose 12 biopsy method was not helpful. 12 biopsy method was helpful in 2/8 (25%) whose TRUS findings were non-specific and 1/21 (4.8%) whose TRUS findings were abnormal. Small low echoic lesion was seen in one patients whose 12 biopsy method was helpful, but cancer was found in other area. TRUS-guided 12 core biopsy method may be superior to

  10. Robot-assisted 3D-TRUS guided prostate brachytherapy: System integration and validation

    International Nuclear Information System (INIS)

    Wei Zhouping; Wan Gang; Gardi, Lori; Mills, Gregory; Downey, Donal; Fenster, Aaron

    2004-01-01

    Current transperineal prostate brachytherapy uses transrectal ultrasound (TRUS) guidance and a template at a fixed position to guide needles along parallel trajectories. However, pubic arch interference (PAI) with the implant path obstructs part of the prostate from being targeted by the brachytherapy needles along parallel trajectories. To solve the PAI problem, some investigators have explored other insertion trajectories than parallel, i.e., oblique. However, parallel trajectory constraints in current brachytherapy procedure do not allow oblique insertion. In this paper, we describe a robot-assisted, three-dimensional (3D) TRUS guided approach to solve this problem. Our prototype consists of a commercial robot, and a 3D TRUS imaging system including an ultrasound machine, image acquisition apparatus and 3D TRUS image reconstruction, and display software. In our approach, we use the robot as a movable needle guide, i.e., the robot positions the needle before insertion, but the physician inserts the needle into the patient's prostate. In a later phase of our work, we will include robot insertion. By unifying the robot, ultrasound transducer, and the 3D TRUS image coordinate systems, the position of the template hole can be accurately related to 3D TRUS image coordinate system, allowing accurate and consistent insertion of the needle via the template hole into the targeted position in the prostate. The unification of the various coordinate systems includes two steps, i.e., 3D image calibration and robot calibration. Our testing of the system showed that the needle placement accuracy of the robot system at the 'patient's' skin position was 0.15 mm±0.06 mm, and the mean needle angulation error was 0.07 deg. . The fiducial localization error (FLE) in localizing the intersections of the nylon strings for image calibration was 0.13 mm, and the FLE in localizing the divots for robot calibration was 0.37 mm. The fiducial registration error for image calibration was 0

  11. Needle bar for warp knitting machines

    Science.gov (United States)

    Hagel, Adolf; Thumling, Manfred

    1979-01-01

    Needle bar for warp knitting machines with a number of needles individually set into slits of the bar and having shafts cranked to such an extent that the head section of each needle is in alignment with the shaft section accommodated by the slit. Slackening of the needles will thus not influence the needle spacing.

  12. Shoulder-Mounted Robot for MRI-guided arthrography: Accuracy and mounting study.

    Science.gov (United States)

    Monfaredi, R; Wilson, E; Sze, R; Sharma, K; Azizi, B; Iordachita, I; Cleary, K

    2015-08-01

    A new version of our compact and lightweight patient-mounted MRI-compatible 4 degree-of-freedom (DOF) robot for MRI-guided arthrography procedures is introduced. This robot could convert the traditional two-stage arthrography procedure (fluoroscopy-guided needle insertion followed by a diagnostic MRI scan) to a one-stage procedure, all in the MRI suite. The results of a recent accuracy study are reported. A new mounting technique is proposed and the mounting stability is investigated using optical and electromagnetic tracking on an anthropomorphic phantom. Five volunteer subjects including 2 radiologists were asked to conduct needle insertion in 4 different random positions and orientations within the robot's workspace and the displacement of the base of the robot was investigated during robot motion and needle insertion. Experimental results show that the proposed mounting method is stable and promising for clinical application.

  13. MRI-guided robotic system for transperineal prostate interventions: proof of principle

    International Nuclear Information System (INIS)

    Van den Bosch, Michiel R; Moman, Maaike R; Van Vulpen, Marco; Battermann, Jan J; Lagendijk, Jan J W; Moerland, Marinus A; Duiveman, Ed; Van Schelven, Leonard J; De Leeuw, Hendrik

    2010-01-01

    In this study, we demonstrate the proof of principle of the University Medical Center Utrecht (UMCU) robot dedicated to magnetic resonance imaging (MRI)-guided interventions in patients. The UMCU robot consists of polymers and non-ferromagnetic materials. For transperineal prostate interventions, it can be placed between the patient's legs inside a closed bore 1.5T MR scanner. The robot can manually be translated and rotated resulting in five degrees of freedom. It contains a pneumatically driven tapping device to automatically insert a needle stepwise into the prostate using a controller unit outside the scanning room. To define the target positions and to verify the needle insertion point and the needle trajectory, a high-resolution 3D balanced steady state free precession (bSSFP) scan that provides a T2/T1-weighted contrast is acquired. During the needle insertion fast 2D bSSFP images are generated to track the needle on-line. When the target position is reached, the radiation oncologist manually places a fiducial gold marker (small seed) at this location. In total two needle trajectories are used to place all markers. Afterwards, a high-resolution 3D bSSFP scan is acquired to visualize the fiducial gold markers. Four fiducial gold markers were placed transperineally into the prostate of a patient with a clinical stage T3 prostate cancer. In the generated scans, it was possible to discriminate the patient's anatomy, the needle and the markers. All markers were delivered inside the prostate. The procedure time was 1.5 h. This study proves that MRI-guided needle placement and seed delivery in the prostate with the UMCU robot are feasible. (note)

  14. MRI-guided robotic system for transperineal prostate interventions: proof of principle

    Energy Technology Data Exchange (ETDEWEB)

    Van den Bosch, Michiel R; Moman, Maaike R; Van Vulpen, Marco; Battermann, Jan J; Lagendijk, Jan J W; Moerland, Marinus A [Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht (Netherlands); Duiveman, Ed; Van Schelven, Leonard J [Medical Technology and Clinical Physics, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht (Netherlands); De Leeuw, Hendrik [Image Sciences Institute, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht (Netherlands)], E-mail: M.R.vandenBosch@umcutrecht.nl

    2010-03-07

    In this study, we demonstrate the proof of principle of the University Medical Center Utrecht (UMCU) robot dedicated to magnetic resonance imaging (MRI)-guided interventions in patients. The UMCU robot consists of polymers and non-ferromagnetic materials. For transperineal prostate interventions, it can be placed between the patient's legs inside a closed bore 1.5T MR scanner. The robot can manually be translated and rotated resulting in five degrees of freedom. It contains a pneumatically driven tapping device to automatically insert a needle stepwise into the prostate using a controller unit outside the scanning room. To define the target positions and to verify the needle insertion point and the needle trajectory, a high-resolution 3D balanced steady state free precession (bSSFP) scan that provides a T2/T1-weighted contrast is acquired. During the needle insertion fast 2D bSSFP images are generated to track the needle on-line. When the target position is reached, the radiation oncologist manually places a fiducial gold marker (small seed) at this location. In total two needle trajectories are used to place all markers. Afterwards, a high-resolution 3D bSSFP scan is acquired to visualize the fiducial gold markers. Four fiducial gold markers were placed transperineally into the prostate of a patient with a clinical stage T3 prostate cancer. In the generated scans, it was possible to discriminate the patient's anatomy, the needle and the markers. All markers were delivered inside the prostate. The procedure time was 1.5 h. This study proves that MRI-guided needle placement and seed delivery in the prostate with the UMCU robot are feasible. (note)

  15. An automated optimization tool for high-dose-rate (HDR) prostate brachytherapy with divergent needle pattern

    Science.gov (United States)

    Borot de Battisti, M.; Maenhout, M.; de Senneville, B. Denis; Hautvast, G.; Binnekamp, D.; Lagendijk, J. J. W.; van Vulpen, M.; Moerland, M. A.

    2015-10-01

    Focal high-dose-rate (HDR) for prostate cancer has gained increasing interest as an alternative to whole gland therapy as it may contribute to the reduction of treatment related toxicity. For focal treatment, optimal needle guidance and placement is warranted. This can be achieved under MR guidance. However, MR-guided needle placement is currently not possible due to space restrictions in the closed MR bore. To overcome this problem, a MR-compatible, single-divergent needle-implant robotic device is under development at the University Medical Centre, Utrecht: placed between the legs of the patient inside the MR bore, this robot will tap the needle in a divergent pattern from a single rotation point into the tissue. This rotation point is just beneath the perineal skin to have access to the focal prostate tumor lesion. Currently, there is no treatment planning system commercially available which allows optimization of the dose distribution with such needle arrangement. The aim of this work is to develop an automatic inverse dose planning optimization tool for focal HDR prostate brachytherapy with needle insertions in a divergent configuration. A complete optimizer workflow is proposed which includes the determination of (1) the position of the center of rotation, (2) the needle angulations and (3) the dwell times. Unlike most currently used optimizers, no prior selection or adjustment of input parameters such as minimum or maximum dose or weight coefficients for treatment region and organs at risk is required. To test this optimizer, a planning study was performed on ten patients (treatment volumes ranged from 8.5 cm3to 23.3 cm3) by using 2-14 needle insertions. The total computation time of the optimizer workflow was below 20 min and a clinically acceptable plan was reached on average using only four needle insertions.

  16. A comparison of prostate tumor targeting strategies using magnetic resonance imaging-targeted, transrectal ultrasound-guided fusion biopsy.

    Science.gov (United States)

    Martin, Peter R; Cool, Derek W; Fenster, Aaron; Ward, Aaron D

    2018-03-01

    Magnetic resonance imaging (MRI)-targeted, three-dimensional (3D) transrectal ultrasound (TRUS)-guided prostate biopsy aims to reduce the 21-47% false-negative rate of clinical two-dimensional (2D) TRUS-guided systematic biopsy, but continues to yield false-negative results. This may be improved via needle target optimization, accounting for guidance system errors and image registration errors. As an initial step toward the goal of optimized prostate biopsy targeting, we investigated how needle delivery error impacts tumor sampling probability for two targeting strategies. We obtained MRI and 3D TRUS images from 49 patients. A radiologist and radiology resident assessed these MR images and contoured 81 suspicious regions, yielding tumor surfaces that were registered to 3D TRUS. The biopsy system's root-mean-squared needle delivery error (RMSE) and systematic error were modeled using an isotropic 3D Gaussian distribution. We investigated two different prostate tumor-targeting strategies using (a) the tumor's centroid and (b) a ring in the lateral-elevational plane. For each simulation, targets were spaced at equal arc lengths on a ring with radius equal to the systematic error magnitude. A total of 1000 biopsy simulations were conducted for each tumor, with RMSE and systematic error magnitudes ranging from 1 to 6 mm. The difference in median tumor sampling probability and probability of obtaining a 50% core involvement was determined for ring vs centroid targeting. Our simulation results indicate that ring targeting outperformed centroid targeting in situations where systematic error exceeds RMSE. In these instances, we observed statistically significant differences showing 1-32% improvement in sampling probability due to ring targeting. Likewise, we observed statistically significant differences showing 1-39% improvement in 50% core involvement probability due to ring targeting. Our results suggest that the optimal targeting scheme for prostate biopsy depends on

  17. Stereotactic large-core needle breast biopsy: analysis of pain and discomfort related to the biopsy procedure

    International Nuclear Information System (INIS)

    Hemmer, Judith M.; Heesewijk, Hans P.M. van; Kelder, Johannes C.

    2008-01-01

    The purpose of this study was to determine the significance of variables such as duration of the procedure, type of breast tissue, number of passes, depth of the biopsies, underlying pathology, the operator performing the procedure, and their effect on women's perception of pain and discomfort during stereotactic large-core needle breast biopsy. One hundred and fifty consecutive patients with a non-palpable suspicious mammographic lesions were included. Between three and nine 14-gauge breast passes were taken using a prone stereotactic table. Following the biopsy procedure, patients were asked to complete a questionnaire. There was no discomfort in lying on the prone table. There is no relation between type of breast lesion and pain, underlying pathology and pain and performing operator and pain. The type of breast tissue is correlated with pain experienced from biopsy (P = 0.0001). We found out that patients with dense breast tissue complain of more pain from biopsy than patients with more involution of breast tissue. The depth of the biopsy correlates with pain from biopsy (P = 0.0028). Deep lesions are more painful than superficial ones. There is a correlation between the number of passes and pain in the neck (P = 0.0188) and shoulder (P = 0.0366). The duration of the procedure is correlated with pain experienced in the neck (P = 0.0116) but not with pain experienced from biopsy. (orig.)

  18. Using insulin pen needles up to five times does not affect needle tip shape nor increase pain intensity.

    Science.gov (United States)

    Puder, Jardena J; Atar, Michael; Muller, Beat; Pavan, Marco; Keller, Ulrich

    2005-02-01

    Reusing insulin pen needles could help to reduce the increasing economic burden of diabetes. We tested the hypothesis that reusing insulin pen needles leads to needle tip deformity and increased pain. Three blinded reviewers assessed 123 electron microscope pictures analyzing needle tip deformity of insulin pen needles used up to four times by diabetic subjects and up to five times by blinded non-diabetic volunteers. The estimated frequency of needle use was correlated to the actual number of needle use. Pain intensity and unpleasantness of each injection were measured by a visual analogue scale and their differences analyzed by Kruskal-Wallis analysis of variance. Unused needles could be differentiated visually from used needles. However, there was no correlation between the actual and guessed number of times a needle was used (r = 0.07, P = 0.2). Evaluating all 270 injections, neither pain intensity nor unpleasantness increased with repeated injections of the same needles in people with diabetes (P = 0.1 and 0.96) and in the volunteers (P = 0.63 and 0.92). Using pen needles four to five times does not lead to progressive needle tip deformity and does not increase pain intensity or unpleasantness, but could increase convenience and lead to substantial financial savings in Europe of around EUR 100 million/year.

  19. Brachytherapy needle deflection evaluation and correction

    International Nuclear Information System (INIS)

    Wan Gang; Wei Zhouping; Gardi, Lori; Downey, Donal B.; Fenster, Aaron

    2005-01-01

    In prostate brachytherapy, an 18-gauge needle is used to implant radioactive seeds. This thin needle can be deflected from the preplanned trajectory in the prostate, potentially resulting in a suboptimum dose pattern and at times requiring repeated needle insertion to achieve optimal dosimetry. In this paper, we report on the evaluation of brachytherapy needle deflection and bending in test phantoms and two approaches to overcome the problem. First we tested the relationship between needle deflection and insertion depth as well as whether needle bending occurred. Targeting accuracy was tested by inserting a brachytherapy needle to target 16 points in chicken tissue phantoms. By implanting dummy seeds into chicken tissue phantoms under 3D ultrasound guidance, the overall accuracy of seed implantation was determined. We evaluated methods to overcome brachytherapy needle deflection with three different insertion methods: constant orientation, constant rotation, and orientation reversal at half of the insertion depth. Our results showed that needle deflection is linear with needle insertion depth, and that no noticeable bending occurs with needle insertion into the tissue and agar phantoms. A 3D principal component analysis was performed to obtain the population distribution of needle tip and seed position relative to the target positions. Our results showed that with the constant orientation insertion method, the mean needle targeting error was 2.8 mm and the mean seed implantation error was 2.9 mm. Using the constant rotation and orientation reversal at half insertion depth methods, the deflection error was reduced. The mean needle targeting errors were 0.8 and 1.2 mm for the constant rotation and orientation reversal methods, respectively, and the seed implantation errors were 0.9 and 1.5 mm for constant rotation insertion and orientation reversal methods, respectively

  20. Ultrasonographic Features of Tuberculous Cervical Lymphadenitis

    Directory of Open Access Journals (Sweden)

    Chen-Han Chou

    2014-09-01

    Full Text Available Making an accurate diagnosis of tuberculous cervical lymphadenitis (TCL has been a problem to clinicians because it is a versatile masquerader and is often confused with lymphomas or cervical metastases. Ultrasound (US has advantages over other examination modalities in that it is noninvasive, inexpensive, time-saving, and able to guide procedures such as fine-needle aspiration and core-needle biopsy. It is increasingly being recognized as a primary tool for the evaluation of cervical lymph nodes. In this article, we present six cases with microscopically and/or pathologically confirmed TCL and illustrate the US features. A literature review was also conducted. The key US features of TCL include hypoechogenecity, strong internal echoes, echogenic thin layers, nodal matting, soft tissue changes, and displaced hilar vascularity. US is a reliable and effective tool in assessing cervical lymphadenopathies. When TCL is suspected under US, US-guided procedures such as fine-needle aspiration or core-needle biopsy can be conducted concomitantly to obtain the microscopic or pathological proof.