WorldWideScience

Sample records for guglielmi detachable coil

  1. Unruptured aneurysms with cranial nerve symptoms: efficacy of endosaccular guglielmi detachable coil treatment

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Joon; Kim, Dong Ik; Lee, Seung Koo; Kim, Si Yeon [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2003-09-01

    To evaluate the efficacy of endosaccular Guglielmi detachable coil (GDC) treatment of unruptured aneurysms causing cranial nerve (CN) symptoms. Among a database of 218 patients whose aneurysms were treated using GDC, seven patients met the criteria for unruptured aneurysms presenting with symptoms and signs of CN palsy. Changes in CN symptoms before and after GDC treatment were reviewed. Aneurysms were located in the internal carotid-posterior communicating artery (n=3), the basilar bifurcation (n=1) and the cavernous internal carotid artery (n=3). CN symptoms included ptosis (n=6), mydriasis (n=2), and extraocular muscle (EOM) disorder (CN III: n=4; CN VI: n=3). Overall, improvement or resolution of CN symptoms after treatment was noted in five patients. CN symptoms in cases involving small (10 mm) and intradural aneurysms tended to respond better to GDC treatment. Ptosis was the initial symptom to show improvement, while EOM dysfunction responded least favourably. GDC coil packing appears to be an appropriate treatment method for the relief of CN symptoms associated with intracranial aneurysms.

  2. Usefulness of the Guglielmi detachable coil for embolization of a systemic venous collateral after Fontan operation: A case report.

    Science.gov (United States)

    Sonomura, Tetsuo; Ikoma, Akira; Kawai, Nobuyuki; Suenaga, Tomohiro; Takeuchi, Takashi; Suzuki, Hiroyuki; Uchita, Shunji; Nakai, Motoki; Minamiguchi, Hiroki; Kishi, Kazushi; Sato, Morio

    2012-09-28

    Embolization of collateral veins is often treated with rigid coils (Gianturco and interlocking detachable coils type). However, when dealing with tortuous and dilated collateral veins, there is a high risk for technical failure and coil migration due to inflexibility of the coils. To safely and successfully solve this problem, Guglielmi detachable coils (GDC) can be used for embolization. Their flexibility allows for easy navigation in tortuous veins, low risk of unintended coil release or coil migration, and safe deployment. A 12-year-old girl with a single ventricle had severe cyanosis and a low exercise tolerance 5 years after Fontan procedure. The symptoms were caused by a tortuous and dilated collateral from the left phrenic vein into the left pulmonary vein, forming a right-to-left shunt. The collateral, which had a large diameter and high flow, and therefore a high risk of coil migration, was successfully embolized with 8 GDC. There were no complications such as coil migration or cerebral infarction. Transcatheter embolization increased her systemic oxygen saturation from 81%-84% to 94%-95%, and increased her ability to exercise. The embolization procedure using flexible GDC was low risk compared with other rigid coil embolization techniques when performing embolization of tortuous and dilated collateral veins.

  3. Procedure-related haemorrhage in embolisation of intracranial aneurysms with Guglielmi detachable coils

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, B.J.; Kim, K.H. [Department of Radiology, Seoul National University College of Medicine, 28 Yongon-Dong, Chongno-Ku, 110-744, Seoul (Korea); Han, M.H.; Chang, K.H. [Department of Radiology, Seoul National University College of Medicine, 28 Yongon-Dong, Chongno-Ku, 110-744, Seoul (Korea); Clinical Research Institute, Seoul National University Hospital, 28 Yongon-Dong, Chongno-Ku, 110-744, Seoul (Korea); Institute of Radiation Medicine, Seoul National University Medical Research Centre, 28 Yongon-Dong, Chongno-Ku, 110-744, Seoul (Korea); Seoul National University College of Medicine (Korea); Oh, C.W. [Department of Neurosurgery, Seoul National University College of Medicine, 28 Yongon-Dong, Chongno-Ku, 110-744, Seoul (Korea)

    2003-08-01

    We reviewed the haemorrhagic complications of the endovascular treatment of intracranial aneurysms, in terms of frequency, pre-embolisation clinical status, clinical and radiological manifestations, management and prognosis. In 275 patients treated for 303 aneurysms over 7 years we had seven (one man and six women - 2.3%) with haemorrhage during or immediately after endovascular treatment. All procedures were performed with a standardised protocol of heparinisation and anaesthesia. Four had ruptured aneurysms, two at the tip of the basilar artery, and one ach on the internal carotid and posterior cerebral artery, treated after 12, 5, 14, and 2 days, respectively, three were in Hunt and Hess grade 2 and one in grade 1. Bleeding occurred during coiling in three, after placement of at least four coils, and during manipulation of the guidewire to enter the aneurysm in the fourth. Haemorrhage was manifest as extravasation of contrast medium, with a sudden rise in systolic blood pressure in three patients. The other three patients had unruptured aneurysms; they had stable blood pressure and angiographic findings during the procedure, but one, under sedation, had seizures immediately after insertion of four coils, and the other two had seizures, headache and vomiting on the day following the procedure. Heparin reversal with protamine sulphate was started promptly started when bleeding was detected in four patients, and the embolisation was completed with additional coils in three. Emergency ventricular drainage was performed in the two patients with ruptured aneurysm and one with an unruptured aneurysm who had abnormal neurological responses or hydrocephalus. The bleeding caused a third nerve palsy in one patient, which might have been due to ischaemia and progressively improved. (orig.)

  4. The possibility and the countermeasure of the re-rupture within procedure in the embolization of intracranial aneurysms with Guglielmi detachable coils

    International Nuclear Information System (INIS)

    Li Minghua; Gu Binxian; Cheng Yingsheng; Fang Chun; Wang Wu; Xu Tao; Xu Shiding

    2004-01-01

    Objective: To study the possibility and the way to deal with the re-rupture within procedure for rupture aneurysms with Guglielmi detachable coil (GDC) embolization. Methods: When 159 cases with intracranial aneurysms were treated with GDC embolization, the rupture during procedure occurred in 7 cases. Of them, the re-rupture was related to microguidewire in one cases, related to coils in 3 cases, related to microcatheter in 2 cases, and related to over-packing with coils in one case. Results: A continuous packing with GDC with or without microcatheter adjustment, till a total occlusion of aneurysm, was performed in 3 cases with re-rupture related to coils and in 2 cases with re-rupture related to microcatheter. Of them, a complete recovery was acquired in 4 and a monoplegia remained in one case; Both the case with re-rupture related to microguidewire and the case with re-rupture related to over-packing with coils died due to intracerebral over-bleeding. Conclusion: It is unavoidable that the re-rupture occurred during the procedure of GDC embolization of intracranial aneurysms. Its occurrence is in inverse proportion with operator's experience. The proper choice of coils may reduce the occurrence of re-rupture related to procedure. A continuous packing with coils is possible to get a total occlusion without any sequels in re-ruptured aneurysms

  5. Endovascular therapy of arteriovenous fistulae with electrolytically detachable coils

    Energy Technology Data Exchange (ETDEWEB)

    Jansen, O.; Doerfler, A.; Forsting, M.; Hartmann, M.; Kummer, R. von; Tronnier, V.; Sartor, K. [Dept. of Neuroradiology, University of Heidelberg Medical School (Germany)

    1999-12-01

    We report our experience in using Guglielmi electrolytically detachable coils (GDC) alone or in combination with other materials in the treatment of intracranial or cervical high-flow fistulae. We treated 14 patients with arteriovenous fistulae on brain-supplying vessels - three involving the external carotid or the vertebral artery, five the cavernous sinus and six the dural sinuses - by endovascular occlusion using electrolytically detachable platinum coils. The fistula was caused by trauma in six cases. In one case Ehlers-Danlos syndrome was the underlying disease, and in the remaining seven cases no aetiology could be found. Fistulae of the external carotid and vertebral arteries and caroticocavernous fistulae were reached via the transarterial route, while in all dural fistulae a combined transarterial-transvenous approach was chosen. All fistulae were treated using electrolytically detachable coils. While small fistulae could be occluded with electrolytically detachable coils alone, large fistulae were treated by using coils to build a stable basket for other types of coil or balloons. In 11 of the 14 patients, endovascular treatment resulted in complete occlusion of the fistula; in the remaining three occlusion was subtotal. Symptoms and signs were completely abolished by this treatment in 12 patients and reduced in 2. On clinical and neuroradiological follow-up (mean 16 months) no reappearance of symptoms was recorded. (orig.)

  6. Giant High-Flow Type Pulmonary Arteriovenous Malformation: Coil Embolization with Flow Control by Balloon Occlusion and an Anchored Detachable Coil

    Energy Technology Data Exchange (ETDEWEB)

    Kanematsu, Masayuki; Kondo, Hiroshi; Goshima, Satoshi; Tsuge, Yusuke; Watanabe, Haruo [Gifu University Hospital, Gifu (Japan); Moriyama, Noriyuki [National Cancer Center Hospital, Tokyo (Japan)

    2012-01-15

    Pulmonary arteriovenous malformations (PAVMs) are often treated by pushable fibered or non-fibered microcoils, using an anchor or scaffold technique or with an Amplatzer plug through a guiding sheath. When performing percutaneous transcatheter microcoil embolization, there is a risk of coil migration, particularly with high-flow type PAVMs. The authors report on a unique treatment in a patient with a giant high-flow PAVM whose nidus had a maximum diameter of 6 cm. A detachable coil, not detached from a delivery wire (an anchored detachable coil), was first placed in the feeding artery under flow control by balloon occlusion, and then multiple microcoils were packed proximally to the anchored detachable coil. After confirming the stability of the microcoils during a gradual deflation of the balloon, we finally released the first detachable coil. The nidus was reduced in size to 15 mm at one year postoperatively.

  7. Giant High-Flow Type Pulmonary Arteriovenous Malformation: Coil Embolization with Flow Control by Balloon Occlusion and an Anchored Detachable Coil

    International Nuclear Information System (INIS)

    Kanematsu, Masayuki; Kondo, Hiroshi; Goshima, Satoshi; Tsuge, Yusuke; Watanabe, Haruo; Moriyama, Noriyuki

    2012-01-01

    Pulmonary arteriovenous malformations (PAVMs) are often treated by pushable fibered or non-fibered microcoils, using an anchor or scaffold technique or with an Amplatzer plug through a guiding sheath. When performing percutaneous transcatheter microcoil embolization, there is a risk of coil migration, particularly with high-flow type PAVMs. The authors report on a unique treatment in a patient with a giant high-flow PAVM whose nidus had a maximum diameter of 6 cm. A detachable coil, not detached from a delivery wire (an anchored detachable coil), was first placed in the feeding artery under flow control by balloon occlusion, and then multiple microcoils were packed proximally to the anchored detachable coil. After confirming the stability of the microcoils during a gradual deflation of the balloon, we finally released the first detachable coil. The nidus was reduced in size to 15 mm at one year postoperatively.

  8. Complex shaped detachable platinum coil system for the treatment of cerebral aneurysms: the Codman Trufill DCS and Trufill DCS Orbit Detachable Coil System COMPLEX Registry final results.

    Science.gov (United States)

    Bendok, Bernard R; Rahme, Rudy J

    2013-01-01

    To report on an electronic database with longitudinal information on the use of bare platinum coils for the endovascular occlusion of cerebral aneurysms. We report here the final analysis of the data. From 1 May 2004 to 10 July 2007, a global registry was conducted at 36 centers in the USA, Europe and Latin America. 303 patients were enrolled, of whom 299 patients were treated with bare detachable platinum coils (mostly Trufill Detachable Coil System (DCS) Orbit coils). Short and long term anatomical and clinical data were collected. Logistic regression analysis was used to examine the association of selected patient characteristics to outcomes of recanalization and retreatment. 313 aneurysms, ruptured and unruptured, were treated in the 299 patients. Follow-up data were available on 185 patients: 150 (81%) had a 3-6 month follow-up, 63 (34%) had a 1 year follow-up and five (3%) had a 2 year follow-up. This paper reviews the status of 185 patients with follow-up data available at this time. Immediately postprocedure, 114 (58%) aneurysms were completely obliterated, 40 (20%) residual neck, 23 (12%) residual aneurysm and 19 (10%) dog ear. Of 174 aneurysms in 167 patients with angiographic follow-up, 137 (79%) remained stable or improved, nine (5%) showed aneurysm regrowth, 26 (15%) showed compaction and two (1%) had migrated. At 3-6 months, 11 of the 174 (6%) aneurysms were re-treated. These results confirm previous outcome data of endovascular occlusion of cerebral aneurysms with Trufill DCS Orbit complex shaped detachable platinum coils. Complications related to the device were rare.

  9. Endovascular treatment of unruptured intracranial aneurysms with Guglielmi detachable coils: short- and long-term results of a single-centre series.

    Science.gov (United States)

    Standhardt, Harald; Boecher-Schwarz, Hans; Gruber, Andreas; Benesch, Thomas; Knosp, Engelbert; Bavinzski, Gerhard

    2008-03-01

    Purpose of the present study is to evaluate the clinical outcome of endovascular treatment of unruptured intracranial aneurysms and to address the question of long-term stability and protection against future subarachnoid hemorrhage. Retrospective analysis of all patients treated in a 12-year period (173 patients: age 26 to 76 yr, mean 52.2+/-10.8/202 aneurysms: size 3 to 50 mm, mean 10.0+/-8.3). The mortality was 0.5%; the overall morbidity was 3.5%. The most frequent complications were thromboembolic events (10.9%). Of these, 3.0% of patients suffered a stroke, leading to severe disability in 1 patient (0.5%). In 1 patient, the aneurysm ruptured during treatment, resulting in relevant neurological disability. Another patient suffered a fatal aneurysm rupture hours after treatment. The occlusion rate depended on aneurysm and neck size. Follow-up angiography revealed a decrease of the occlusion rate over time. This trend was obvious in all size categories and was most pronounced in giant aneurysms. In 3 patients (1.5%) with partially thrombosed giant aneurysms of the posterior circulation, embolization could not prevent later aneurysm rupture. There were no ruptures of any other aneurysms in the follow-up period (3.7+/-3.4 yr). Endovascular treatment is a highly safe procedure with low intervention-related morbidity and mortality. Long-term data for nongiant aneurysms showed good protection against rupture in the observation period. In contrast, the risk of rupture for giant aneurysms of the posterior circulation was as high as expected in observational studies.

  10. Endovascular treatment of posterior cerebral artery aneurysms using detachable coils

    Energy Technology Data Exchange (ETDEWEB)

    Roh, Hong Gee [Kangwon National University Hospital, Department of Radiology, Chuncheon, Kangwon-do (Korea); Konkuk University Hospital, Department of Radiology, Seoul (Korea); Kim, Sam Soo; Han, Heon [Kangwon National University Hospital, Department of Radiology, Chuncheon, Kangwon-do (Korea); Kang, Hyun-Seung [Konkuk University Hospital, Department of Neurosurgery, Seoul (Korea); Moon, Won-Jin [Konkuk University Hospital, Department of Radiology, Seoul (Korea); Byun, Hong Sik [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea)

    2008-03-15

    Aneurysms of the posterior cerebral artery (PCA) are rare, and most of the studies reported in the literature in which the endovascular approach was applied were carried out on a limited number of patients with PCA aneurysms. We retrospectively reviewed our cases of PCA aneurysms - at various locations and of differing shapes - that received endovascular treatment and evaluated the treatment outcome. From January 1996 to December 2006, 13 patients (eight females and five males) with 17 PCA aneurysms (nine fusiform and eight saccular) were treated using the endovascular approach. The age of the patients ranged from 20 to 67 years, with a mean age of 44 years. Of the 13 patients, ten presented with intracranial hemorrhage, and one patient, with a large P2 aneurysm, presented with trigeminal neuralgia; the aneurysms were asymptomatic in the remaining two patients. All 13 patients were successfully treated, with only one procedure-related symptomatic complication. Seven patients were treated by occlusion of the aneurysm and parent artery together; five patients, by selective embolization of the aneurysm; one patient, by partial coiling. Although infarctions were found in two patients treated with selective embolization and in three patients treated with parent artery occlusion, only one patient with a ruptured P2 aneurysm treated with parent artery occlusion developed transient amnesia as an ischemic symptom. Posterior cerebral artery aneurysms can be treated safely with either occlusion of the aneurysm together with the PCA or with a selective coil embolization. Infarctions may occur after endovascular treatment, but they are rarely the cause of a disabling symptom. (orig.)

  11. Prevention and management of intraprocedural rupture of intracranial aneurysm with detachable coils during embolization

    Energy Technology Data Exchange (ETDEWEB)

    Li, Ming-Hua; Gao, Bu-Lang; Fang, Chun; Cheng, Ying-Sheng; Li, Yong-Dong; Wang, Jue [Shanghai Jiaotong University School of Medicine, Department of Radiology, Shanghai Sixth Hospital, Shanghai (China); Xu, Guo-Ping [Fudan University Shanghai Medical College, Department of Pathology, Shanghai (China)

    2006-12-15

    Intracranial aneurysm rupture during embolization with detachable coils is reportedly among the gravest of intraprocedural complications. We present here our experiences with this outcome, and a potential intervention for managing this life-threatening complication. From April 1998 to March 2005, 284 patients with cerebral aneurysms were treated with detachable coils. Intraprocedural aneurysm rupture occurred in ten patients with a history of a previously ruptured aneurysm. In the event of intraprocedural hemorrhage, we routinely performed heparin reversal with protamine sulfate. Of the 221 patients with a previously ruptured aneurysm, intraprocedural aneurysm rupture occurred in 10 (4.5%). These ruptures were caused by a microguidewire in one patient, a microcatheter in one, over-packing in two and a coil perforation in three. In the remaining three patients the ruptures were caused by both the microcatheter and the coils. Three patients died because of aneurysm re-rupture, yielding a mortality rate of 30%. One patient presented with a slight disability in the left leg and no neurological deficits were observed in the remaining six patients. Intraprocedural aneurysm rupture during embolization is a rare, but unavoidable and life-threatening event. Proper measures should be taken to reduce and improve the outcome of this tragic occurrence. The majority of patients with an intraprocedural ruptured aneurysm can survive without severe sequelae if managed appropriately. (orig.)

  12. Prevention and management of intraprocedural rupture of intracranial aneurysm with detachable coils during embolization

    International Nuclear Information System (INIS)

    Li, Ming-Hua; Gao, Bu-Lang; Fang, Chun; Cheng, Ying-Sheng; Li, Yong-Dong; Wang, Jue; Xu, Guo-Ping

    2006-01-01

    Intracranial aneurysm rupture during embolization with detachable coils is reportedly among the gravest of intraprocedural complications. We present here our experiences with this outcome, and a potential intervention for managing this life-threatening complication. From April 1998 to March 2005, 284 patients with cerebral aneurysms were treated with detachable coils. Intraprocedural aneurysm rupture occurred in ten patients with a history of a previously ruptured aneurysm. In the event of intraprocedural hemorrhage, we routinely performed heparin reversal with protamine sulfate. Of the 221 patients with a previously ruptured aneurysm, intraprocedural aneurysm rupture occurred in 10 (4.5%). These ruptures were caused by a microguidewire in one patient, a microcatheter in one, over-packing in two and a coil perforation in three. In the remaining three patients the ruptures were caused by both the microcatheter and the coils. Three patients died because of aneurysm re-rupture, yielding a mortality rate of 30%. One patient presented with a slight disability in the left leg and no neurological deficits were observed in the remaining six patients. Intraprocedural aneurysm rupture during embolization is a rare, but unavoidable and life-threatening event. Proper measures should be taken to reduce and improve the outcome of this tragic occurrence. The majority of patients with an intraprocedural ruptured aneurysm can survive without severe sequelae if managed appropriately. (orig.)

  13. Successful Transcatheter Embolization of Penetrating Aortic Ulcer Using Interlocking Detachable Coils

    International Nuclear Information System (INIS)

    Hama, Yukihiro; Kaji, Tatsumi; Iwasaki, Yoshie; Hinokiyama, Kazuhiro; Shimizu, Masafumi; Kusano, Shoichi

    2000-01-01

    A 54-year-old man with persistent chest pain was hospitalized for hypertension and DeBakey type IIIb aortic dissection. The false lumen of the dissection was almost completely thrombosed; however, a penetrating atherosclerotic ulcer (PAU) was observed 5 weeks later. At that time, we successfully embolized the PAU with a microcatheter and interlocking detachable coils (IDCs). The patient is well with no episodes of relapse in 20 months of follow-up. This case suggests the utility of the microcatheter and IDC system as an alternative to surgery

  14. Embolization of Collateral Vessels Using Mechanically Detachable Coils in Young Children with Congenital Heart Disease

    International Nuclear Information System (INIS)

    Sato, Y.; Ogino, H.; Hara, M.; Satake, M.; Oshima, H.; Banno, T.; Mizuno, K.; Mishima, A.; Shibamoto, Y.

    2003-01-01

    Our objective was to evaluate the usefulness of embolizing collateral vessels using mechanically detachable coils (MDCs) in children aged 3 years or younger with congenital heart disease. The subjects were 8 children with congenital heart disease featuring collateral vessels (age 18 days-3 years): 3 with a single ventricle, 2 with the tetralogy of Fallot, 2 with pulmonary atresia, and 1 with a ventricular septal defect. The embolized vessels were the major aortopulmonary collateral artery (MAPCA) in 5 patients, the persistent left superior vena cava in 2, and the coronary arteriovenous fistula in 1. A 4 or a 5 F catheter was used as the guiding device, and embolization was performed using MDCs and other conventional coils introduced through the microcatheter. One patient had growth of new MAPCAs after embolization, and these MAPCAs were also embolized with MDCs. Thus, a total of 9 embolization procedures were performed in 8 patients. Complete occlusion of the collateral vessels was achieved in 8 of 9 procedures (89%). Seven of 8 patients (88%) had uneventful courses after embolization, and MDC procedures appeared to play important roles in avoiding coil migration and achievement of safe coil embolization. One patient who underwent MAPCA embolization showed no improvement in heart function and died 2 months and 19 days later. Embolization of collateral vessels using MDCs in young children with congenital heart disease can be an effective procedure and a valuable adjunct to surgical management

  15. Is digital substraction angiography still needed for the follow-up of intracranial aneurysms treated by embolisation with detachable coils?

    International Nuclear Information System (INIS)

    Lubicz, Boris; Neugroschl, Carine; Collignon, Laurent; Francois, Olivier; Baleriaux, Danielle

    2008-01-01

    Follow-up of intracranial aneurysms treated by embolisation with detachable coils is mandatory to detect a possible recanalisation. The aim of this study was to compare contrast-enhanced magnetic resonance angiography (CE-MRA) with digital substraction angiography (DSA) used to detect aneurysm recanalisation to determine if DSA is still needed during follow-up. From May 2006 to May 2007, 55 patients with 67 aneurysms were treated by endosaccular coiling with (n=9) or without (n=58) an adjunctive stent. Follow-up imaging protocol included MRA at 6 and 12 months and a DSA at 12 months or earlier if a major recanalisation was identified on the 6-month MRA. Two neuroradiologists independently reviewed MRA images (readers 1 and 2) and two other reviewed DSA images. Follow-up DSA showed stability of the aneurysm occlusion in 52 cases, recanalisation in 14 cases, and further thrombosis in one. On CE-MRA, both readers identified all recanalisations but one (sensitivity of 93%) as they missed a major recanalisation in a 2-mm ruptured aneurysm. There were two false-positive evaluations by reader 1 and three for reader 2. Mean specificity of CE-MRA to detect aneurysm recanalisation was 95.5%. CE-MRA is accurate to detect aneurysm recanalisation after embolisation with detachable coils. CE-MRA may be proposed as first-intention imaging technique for their follow-up. However, its sensitivity and specificity remain inferior to that of DSA and major recurrences may be missed in very small aneurysms. Therefore, a single DSA remains mandatory during the imaging follow-up. (orig.)

  16. Y-stent-assisted coil embolisation of wide-necked aneurysms using a new fully retrievable and detachable intracranial stent: report of two cases.

    Science.gov (United States)

    Muda, Ahmad Sobri; Ralib, Ahmad Razali Md; Yaacob, Yazmin; Zakaria, Rozman; Bakar, Azizi Abu

    2011-10-01

    Endovascular treatment of wide-necked aneurysms poses a challenge for the endovascular therapist. The Y-stent-assisted technique has been used for stent-assisted coil embolisation for wide-necked bifurcation aneurysms. This technique has been described for basilar tip aneurysms and middle cerebral artery bifurcation aneurysms using Neuroform and Enterprise stents. We report 2 cases of wide-necked bifurcation aneurysms that were treated with Y-stent-assisted coil embolisation using a new, fully retrievable and detachable intracranial stent (Solitaire AB™). We describe the advantages of a fully retrievable and detachable stent and its feasibility of forming a Y configuration.

  17. [Coil embolization for incidental aneurysms in patients with chronic renal failure: midterm clinical results of two cases].

    Science.gov (United States)

    Nakashima, T; Katou, T; Murakawa, T; Yamakawa, H; Yoshimura, S; Kaku, Y; Sakai, N

    2000-06-01

    In spite of recent advances in perioperative management, the risk of neurosurgical intervention for patients with chronic renal failure is still considered too high. In this study, coil embolization for incidental aneurysms in such patients is demonstrated in reference to midterm results. A 42-year-old woman with a history of hemodialisis for 7 years presented with subcortical hemorrhage in her right frontal lobe. The magnetic resonance angiography (MRA) demonstrated a distal anterior cerebral artery aneurysm, but it was considered to be unrelated to the hemorrhage. Two and a half months after the hemorrhage the aneurysm was embolized with interlocking detachable coils. Thirty months after embolization, the angiogram revealed the coil compaction and the recanalization of the aneurysm neck. However, 54 months after embolization, the figure of the embolized aneurysm and neck remnant was the same as the previous findings. A 69-year-old woman with a history of hemodialisis for 5 years suddenly experienced left hemiparesis. Computed tomography revealed cerebral infarction in the right frontoparietal white matter. In addition, a left middle cerebral artery aneurysm was unexpectedly found on the MRA. Five months after the onset of the attack, the aneurysm was embolized with a Guglielmi detachable coli. An angiogram obtained 24 months after the embolization showed the aneurysm to be almost completely obliterated. In considering the therapeutic risks and benefits for incidental aneurysms of patients with chronic renal failure, intra-vascular surgery could be recommended as a less invasive treatment.

  18. Materials and techniques for coiling of cerebral aneurysms: how much scientific evidence do we have?

    International Nuclear Information System (INIS)

    Kurre, W.; Berkefeld, J.

    2008-01-01

    Since coils were approved for aneurysm treatment, materials and techniques developed rapidly. It still remains an open question whether one material or method is superior. This article reviews the literature on various coil types and treatment approaches assessing the scientific evidence of its use. Studies on aneurysm treatment with Guglielmi detachable platinum coils, bioactive coils, hydrogel coated coils, and complex designs as well as balloon- and stent-assisted techniques were retrieved by a PubMed database search from 1990 until May 2008. Data were analyzed in terms of aneurysm occlusion, permanent morbidity and mortality, recanalization, and retreatment. We also assessed the level of evidence of the published studies. Only the International Subarachnoid Aneurysm Trial provides level I evidence proving the superiority of endovascular over surgical therapy in ruptured aneurysms. Randomized trials comparing bioactive or hydrogel coated devices with bare coils are ongoing. Other studies were based on registries or case series mainly conducted without control groups. Morbidity, mortality, and initial occlusion rates appear similar for all devices. No clear evidence exists for the superiority of bioactive- or hydrocoils regarding long-term stability. It remains ambiguous whether morbidity and mortality rises with the use of balloons and stents. There is no evidence that routine use of balloons improves treatment durability. Mid-term results of stent-assisted coiling of complex aneurysms appear favorable. There is a lack of studies with a high level of evidence comparing different coiling materials and techniques. Case series and registries were not able to prove the superiority of any device or method. (orig.)

  19. Stent assisted coil embolization of wide-necked bilobed anterior inferior cerebellar artery aneurysm with incorporated artery arising from the dome: a technical note.

    Science.gov (United States)

    Sabharwal, Paramveer Singh; Saini, Jitender; Hanumanthapura Ramalingaiah, Arvinda

    2013-09-01

    A technique for stent-assisted coil embolization of a bilobed wide-necked saccular aneurysm of the anterior inferior cerebellar artery (AICA) with the AICA arising from the dome of the aneurysm is described. A middle-aged patient was referred for treatment of a bilobed saccular aneurysm identified on a CT angiogram performed for a subarachnoid hemorrhage which occurred 20 days prior to presentation. A diagnostic angiogram showed a bilobed wide-necked saccular aneurysm at the AICA origin with the AICA arising from the dome of the aneurysm and also supplying the territory of the posterior inferior cerebellar artery. The therapeutic procedure involved trans-aneurysmal cannulation of the AICA with the microcatheter left in situ. Another microcatheter was maneuvered into the larger dome of the aneurysm. A stent was then deployed in the basilar artery, jailing the previous microcatheter in the aneurysm. Helical Guglielmi detachable coils were deployed in the aneurysm resulting in complete occlusion of the aneurysm with preservation of the AICA. It is important to preserve a normal branch arising from the dome of an aneurysm although it is technically demanding and a relative limitation. This case report describes a technique of coiling a bilobed aneurysm with a vital branch arising from the dome, with preservation of the branch and complete occlusion of the aneurysm using two microcatheters and a stent. This expands the repertoire of endovascular treatment of complex aneurysms.

  20. Retinal Detachment Vision Simulator

    Science.gov (United States)

    ... What Is a Torn or Detached Retina? Retinal Detachment: Torn or Detached Retina Causes Retinal Detachment: Who Is At Risk for a Torn or Detached Retina? Retinal Detachment: Torn or Detached Retina Symptoms Retinal Detachment: Torn or Detached Retina Diagnosis ...

  1. GDC 360 for the endovascular treatment of intracranial aneurysms: a matched-pair study analysing angiographic outcomes with GDC 3D coils in 38 patients

    International Nuclear Information System (INIS)

    Taschner, Christian A.; Thines, Laurent; Lejeune, Jean-Paul; El-Mahdy, Mohamed; Rachdi, Henda; Gauvrit, Jean-Yves; Pruvo, Jean-Pierre; Leclerc, Xavier

    2009-01-01

    The purpose of this study was to determine whether coil embolisation with a new complex-shaped Guglielmi Detachable Coil (GDC 360 ; Boston Scientific Neurovascular, Fremont, CA, USA) has any effect on the stability of aneurysm occlusion. Fifty-one consecutive patients with intracranial aneurysms treated with GDC 360 were included. Angiographic results and adverse neurological events during the follow-up period were recorded. For 38 patients treated with GDC 360 with available follow-up data, a corresponding patient treated with GDC 3D was identified from our database. Matches were sought for rupture status, location, aneurysmal size, and neck size. The angiographic outcome of these matched controls at 6 months was compared to aneurysms treated with GDC 360 . Initial angiographic controls for 38 patients treated with GDC 360 showed complete occlusion in 32 aneurysms, and a neck remnant in six. At 6-month follow-up, complete occlusion was found in 29, a neck remnant in eight, and a residual aneurysm in one. One patient treated with GDC 360 needed retreatment for a major recanalisation. In 38 matched patients treated with GDC 3D, initial angiographic controls found complete aneurysmal occlusion in 30 aneurysms and a residual neck in 8. At 6-month follow-up, 24 aneurysms were completely occluded, ten showed a neck remnant, and residual aneurysms were seen in four. Four patients, treated with GDC 3D, were retreated for major aneurysm recanalisations. Our data suggests that endovascular coil embolisation with GDC 360 might improve long-term stability of coiled aneurysms when compared to GDC 3D. (orig.)

  2. Retinal Detachment

    Science.gov (United States)

    ... specific questions. Retinal Detachment Defined What is retinal detachment? The retina is the light-sensitive layer of tissue that ... the most common. Tractional —In this type of detachment, scar tissue on the retina’s surface contracts and causes the retina to separate ...

  3. Retinal Detachment: Torn or Detached Retina Symptoms

    Science.gov (United States)

    ... Health / Eye Health A-Z Detached or Torn Retina Sections Retinal Detachment: What Is a Torn or ... Detachment Vision Simulator Retinal Detachment: Torn or Detached Retina Symptoms Leer en Español: Síntomas de desgarramiento o ...

  4. Divertor detachment

    Science.gov (United States)

    Krasheninnikov, Sergei

    2015-11-01

    The heat exhaust is one of the main conceptual issues of magnetic fusion reactor. In a standard operational regime the large heat flux onto divertor target reaches unacceptable level in any foreseeable reactor design. However, about two decades ago so-called ``detached divertor'' regimes were found. They are characterized by reduced power and plasma flux on divertor targets and look as a promising solution for heat exhaust in future reactors. In particular, it is envisioned that ITER will operate in a partly detached divertor regime. However, even though divertor detachment was studied extensively for two decades, still there are some issues requiring a new look. Among them is the compatibility of detached divertor regime with a good core confinement. For example, ELMy H-mode exhibits a very good core confinement, but large ELMs can ``burn through'' detached divertor and release large amounts of energy on the targets. In addition, detached divertor regimes can be subject to thermal instabilities resulting in the MARFE formation, which, potentially, can cause disruption of the discharge. Finally, often inner and outer divertors detach at different plasma conditions, which can lead to core confinement degradation. Here we discuss basic physics of divertor detachment including different mechanisms of power and momentum loss (ionization, impurity and hydrogen radiation loss, ion-neutral collisions, recombination, and their synergistic effects) and evaluate the roles of different plasma processes in the reduction of the plasma flux; detachment stability; and an impact of ELMs on detachment. We also evaluate an impact of different magnetic and divertor geometries on detachment onset, stability, in- out- asymmetry, and tolerance to the ELMs. Supported by the U.S. Department of Energy Office of Science, Office of Fusion Energy Sciences under Award Number DE-DE-FG02-04ER54739 at UCSD.

  5. ARCIMBOLDO on coiled coils.

    Science.gov (United States)

    Caballero, Iracema; Sammito, Massimo; Millán, Claudia; Lebedev, Andrey; Soler, Nicolas; Usón, Isabel

    2018-03-01

    ARCIMBOLDO solves the phase problem by combining the location of small model fragments using Phaser with density modification and autotracing using SHELXE. Mainly helical structures constitute favourable cases, which can be solved using polyalanine helical fragments as search models. Nevertheless, the solution of coiled-coil structures is often complicated by their anisotropic diffraction and apparent translational noncrystallographic symmetry. Long, straight helices have internal translational symmetry and their alignment in preferential directions gives rise to systematic overlap of Patterson vectors. This situation has to be differentiated from the translational symmetry relating different monomers. ARCIMBOLDO_LITE has been run on single workstations on a test pool of 150 coiled-coil structures with 15-635 amino acids per asymmetric unit and with diffraction data resolutions of between 0.9 and 3.0 Å. The results have been used to identify and address specific issues when solving this class of structures using ARCIMBOLDO. Features from Phaser v.2.7 onwards are essential to correct anisotropy and produce translation solutions that will pass the packing filters. As the resolution becomes worse than 2.3 Å, the helix direction may be reversed in the placed fragments. Differentiation between true solutions and pseudo-solutions, in which helix fragments were correctly positioned but in a reverse orientation, was found to be problematic at resolutions worse than 2.3 Å. Therefore, after every new fragment-placement round, complete or sparse combinations of helices in alternative directions are generated and evaluated. The final solution is once again probed by helix reversal, refinement and extension. To conclude, density modification and SHELXE autotracing incorporating helical constraints is also exploited to extend the resolution limit in the case of coiled coils and to enhance the identification of correct solutions. This study resulted in a specialized mode

  6. MR angiography after coiling of intracranial aneurysms

    NARCIS (Netherlands)

    Schaafsma, J.D.

    2012-01-01

    Introduction Endovascular occlusion with detachable coils has become an alternative treatment to neurosurgical clipping of intracranial aneurysms over the last two decades. Its minimal invasiveness is the most important advantage of this treatment compared to clipping. The disadvantage of occlusion

  7. Retinal Detachment: Torn or Detached Retina Diagnosis

    Science.gov (United States)

    ... Health / Eye Health A-Z Detached or Torn Retina Sections Retinal Detachment: What Is a Torn or ... Detachment Vision Simulator Retinal Detachment: Torn or Detached Retina Diagnosis Leer en Español: Diagnóstico de un desgarramiento ...

  8. Coiling of ruptured pericallosal artery aneurysms.

    NARCIS (Netherlands)

    Menovsky, T.; Rooij, W.J.J. van; Sluzewski, M.; Wijnalda, D.

    2002-01-01

    OBJECTIVE: To assess the technical feasibility of treating ruptured pericallosal artery aneurysms with detachable coils and to evaluate the anatomic and clinical results. METHODS: Over a period of 27 months, 12 patients with a ruptured pericallosal artery aneurysm were treated with detachable

  9. Retinal Detachment

    Directory of Open Access Journals (Sweden)

    Adnan Riaz, MD

    2018-04-01

    Full Text Available History of present illness: A 58-year-old female presented to the emergency department reporting six days of progressive, atraumatic left eye vision loss. Her symptoms started with the appearance of dark spots and “spider webs,” and then progressed to darkening of vision in her left eye. She reports mild pain since yesterday. Her review of symptoms was otherwise negative. Ocular physical examination revealed normal external appearance, intact extraocular movements, and visual acuities of 20/25 OD and light/dark sensitivity OS. Fluorescein uptake was negative and slit lamp exam was unremarkable. Significant findings: Bedside ocular ultrasound revealed a serpentine, hyperechoic membrane that appeared tethered to the optic disc posteriorly with hyperechoic material underneath. These findings are consistent with retinal detachment (RD and associated retinal hemorrhage. Discussion: The retina is a layer of organized neurons that line the posterior portion of the posterior chamber of the eye. RD occurs when this layer separates from the underlying epithelium, resulting in ischemia and progressive photoreceptor degeneration, with potentially rapid and permanent vision loss if left untreated.1 Risk factors include advanced age, male sex (60%, race (Asians and Jews, and myopia and lattice degeneration.2 Bedside ultrasound (US performed by emergency physicians provides a valuable tool that has been used by ophthalmologists for decades to evaluate intraocular disease.1,3 Findings on bedside ultrasound consistent with RD include a hyperechoic membrane floating in the posterior chamber. RD usuallyremain tethered to the optic disc posteriorly and do not cross midline, a feature distinguishing them from posterior vitreous detachments. Associated retinal hemorrhage, seen as hyperechoic material under the retinal flap, can often be seen.1,2 US can also distinguish between “mac-on” and “mac-off” detachments. If the retina is still attached to the

  10. Retinal detachment repair

    Science.gov (United States)

    ... area (the macula). This can help prevent further detachment of the retina. It also will increase the chance of preserving ... buckling; Vitrectomy; Pneumatic retinopexy; Laser retinopexy; Rhegmatogenous retinal detachment repair Images ... detachment repair - series References Connolly BP, Regillo ...

  11. Rope coiling

    Indian Academy of Sciences (India)

    Sitichoke Amnuanpol

    2017-10-19

    Oct 19, 2017 ... In rope coiling the centre of the circle is static. How- ever, it evolves in time as seen in the curling of .... friction force between the rope and the plane, because no significant changes in the coiling radius R and ... friction force relative to the axial compressive forces,. i.e. gravitational force and inertial force, ...

  12. Rope coiling

    Indian Academy of Sciences (India)

    We present the results of the combined experimental and theoretical investigation of rope coiling arising from the buckling instability. The shape of the rope is perfectly circular in the coiling region and is straight in the region below the feeding point. In between these two distant regions, the rope assumes a catenary-like ...

  13. α/β coiled coils

    Science.gov (United States)

    Hartmann, Marcus D; Mendler, Claudia T; Bassler, Jens; Karamichali, Ioanna; Ridderbusch, Oswin; Lupas, Andrei N; Hernandez Alvarez, Birte

    2016-01-01

    Coiled coils are the best-understood protein fold, as their backbone structure can uniquely be described by parametric equations. This level of understanding has allowed their manipulation in unprecedented detail. They do not seem a likely source of surprises, yet we describe here the unexpected formation of a new type of fiber by the simple insertion of two or six residues into the underlying heptad repeat of a parallel, trimeric coiled coil. These insertions strain the supercoil to the breaking point, causing the local formation of short β-strands, which move the path of the chain by 120° around the trimer axis. The result is an α/β coiled coil, which retains only one backbone hydrogen bond per repeat unit from the parent coiled coil. Our results show that a substantially novel backbone structure is possible within the allowed regions of the Ramachandran space with only minor mutations to a known fold. DOI: http://dx.doi.org/10.7554/eLife.11861.001 PMID:26771248

  14. Structural specificity in coiled-coil interactions

    OpenAIRE

    Grigoryan, Gevorg; Keating, Amy E.

    2008-01-01

    Coiled coils have a rich history in the field of protein design and engineering. Novel structures, such as the first 7-helix coiled coil, continue to provide surprises and insights. Large-scale data sets quantifying the influence of systematic mutations on coiled-coil stability are a valuable new asset to the area. Scoring methods based on sequence and/or structure can predict interaction preferences in coiled-coil-mediated bZIP transcription factor dimerization. Experimental and computationa...

  15. Coil compaction after embolization of the superior mesenteric artery pseudoaneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Hama, Yukihiro; Iwasaki, Yoshie; Kaji, Tatsumi; Kusano, Shoichi [Department of Radiology, National Defense Medical College, 3-2 Namiki, Tokorozawa, 3590042 Saitama (Japan); Hatsuse, Kazuo [Department of Surgery I, National Defense Medical College, 3-2 Namiki, Tokorozawa, 3590042 Saitama (Japan)

    2002-07-01

    A 58-year-old man with an abscess of the psoas muscle was returned to our hospital with hematemesis. Two years earlier, he had undergone coil embolization for a superior mesenteric artery (SMA) pseudoaneurysm secondary to pancreatitis. Based on the physical examination, serum amylase level, and abdominal radiographs, a diagnosis of acute exacerbation of pancreatitis and coil compaction of the SMA pseudoaneurysm was made. The patient underwent re-embolization for the coil compaction using interlocking detachable coils. His condition improved gradually, and he was discharged 3 weeks later. To our knowledge, this is the first report of coil compaction of SMA pseudoaneurysm. (orig.)

  16. Ejector COIL

    Science.gov (United States)

    Nikolaev, Valeriy D.; Svistun, Michael I.; Zagidullin, Marsel V.

    2004-06-01

    The historical ejector-like chemical oxygen iodine laser (COIL) contribution at the Lebedev Physical Institute, Samara Branch is briefly presented. Two possible schemes of such COIL which provide the high exhaust pressure are considered. The high-pressure hot driver nitrogen is carrier of iodine vapor in the first scheme. In the second version the additional nozzles with the low-pressure secondary nitrogen are employed for injection iodine vapor but the pure high-pressure driver nitrogen has the room temperature. The last COIL version was investigated in Lebedev Physical Institute in more detail and results of these investigations are presented. This ejector nozzle bank generates gain medium with high Mach number, low temperature and high gain. A high chemical efficiency up to 25% and the potential pressure recovery up to 90 torr have been achieved simultaneously.

  17. Retinal Detachment: Torn or Detached Retina Treatment

    Science.gov (United States)

    ... in special positions for a time. Do not fly in an airplane or travel at high altitudes until you are ... With an oil bubble, it is safe to fly on an airplane. Most retinal detachment surgeries (80 to 90 percent) ...

  18. Coiled-Coil Design: Updated and Upgraded.

    Science.gov (United States)

    Woolfson, Derek N

    2017-01-01

    α-Helical coiled coils are ubiquitous protein-folding and protein-interaction domains in which two or more α-helical chains come together to form bundles. Through a combination of bioinformatics analysis of many thousands of natural coiled-coil sequences and structures, plus empirical protein engineering and design studies, there is now a deep understanding of the sequence-to-structure relationships for this class of protein architecture. This has led to considerable success in rational design and what might be termed in biro de novo design of simple coiled coils, which include homo- and hetero-meric parallel dimers, trimers and tetramers. In turn, these provide a toolkit for directing the assembly of both natural proteins and more complex designs in protein engineering, materials science and synthetic biology. Moving on, the increased and improved use of computational design is allowing access to coiled-coil structures that are rare or even not observed in nature, for example α-helical barrels, which comprise five or more α-helices and have central channels into which different functions may be ported. This chapter reviews all of these advances, outlining improvements in our knowledge of the fundamentals of coiled-coil folding and assembly, and highlighting new coiled coil-based materials and applications that this new understanding is opening up. Despite considerable progress, however, challenges remain in coiled-coil design, and the next decade promises to be as productive and exciting as the last.

  19. Crystallographic study on oligonucleotide coiled-coils

    OpenAIRE

    Luchi, Daniela de

    2008-01-01

    En la presente tesis doctoral se han realizado estudios estructurales de DNA. Estudios previos han demostrado que los coiled-coils de d(ATATATATATAT) y d(ATATATATAT) tienen unos parámetros geométricos muy diferentes. El objetivo de esta tesis es aclarar las propiedades de los coiled-coils.Con esta finalidad se han estudiado por cristalografía de Rayos X oligonucleótidos con diferentes secuencias y con extremos cohesivos que fijen la geometría de los coiled-coils. Se han utilizado oligonucleót...

  20. Plasma detachment in divertor tokamaks

    Science.gov (United States)

    Leonard, A. W.

    2018-04-01

    Observations of divertor plasma detachment in tokamaks are reviewed. Plasma detachment is characterized in terms of transport and dissipation of power, momentum and particle flux along the open field lines from the midplane to the divertor. Asymmetries in detachment onset and other characteristics between the inboard and outboard divertor plasmas is found to be primarily driven by plasma E× B drifts. The effect of divertor plate geometry and magnetic configuration on divertor detachment is summarized. Control of divertor detachment has progressed with a development of a number of diagnostics to characterize the detached state in real-time. Finally the compatibility of detached divertor operation with high performance core plasmas is examined.

  1. Predicting coiled coils by use of pairwise residue correlations.

    OpenAIRE

    Berger, B; Wilson, D B; Wolf, E; Tonchev, T; Milla, M; Kim, P S

    1995-01-01

    A method is presented that predicts coiled-coil domains in protein sequences by using pairwise residue correlations obtained from a (two-stranded) coiled-coil database of 58,217 amino acid residues. A program called PAIRCOIL implements this method and is significantly better than existing methods at distinguishing coiled coils from alpha-helices that are not coiled coils. The database of pairwise residue correlations suggests structural features that stabilize or destabilize coiled coils.

  2. Versatile fill coils: initial experience as framing coils for oblong aneurysms. A technical case report.

    Science.gov (United States)

    Osanai, Toshiya; Bain, Mark; Hui, Ferdinand K

    2014-01-01

    Coil embolization of oblong aneurysms is difficult because the majority of commercially available coils are manufactured with a helical or spherical tertiary structure. While adopting framing strategies for oblong aneurysms (aspect ratio ≥ 2: 1), traditional coils may be undersized in the long axis but oversized in the short axis, resulting in increased aneurysmal wall stress, risk of re-rupture, and difficulty creating a basket that respects the aneurysmal neck. We review three cases in which versatile filling coils (VFCs) were used as the initial coils for embolization of oblong aneurysms and report coil distribution characteristics and clinical outcomes. Packing density after VFC implantation was assessed using the software AngioSuite-Neuro edition and AngioCalc. a 58-year-old woman experienced a subarachnoid hemorrhage from a ruptured anterior communicating artery aneurysm (7.5 mm × 3.5 mm). A 3-6 mm × 15 cm VFC was selected as the first coil because the flexibility of its wave-loop structure facilitates framing of an irregularly shaped aneurysm. The loop portions of the structures tend to be pressed to the extremes of the aneurysmal sac by the wave component. The VFC was introduced smoothly into the aneurysmal sac without catheter kickback. We were then able to insert detachable filling coils without any adjunctive technique and achieved complete occlusion. Complete occlusion without severe complications was achieved in all three cases in our study. Average packing density after the first coil was 15.63%. VFC coils may have a specific role in framing oblong aneurysms given their complex loop-wave design, allowing spacing of the coils at the dome and neck while keeping sac stress to a minimum.

  3. Evolutionary patterns in coiled-coils.

    Science.gov (United States)

    Surkont, Jaroslaw; Pereira-Leal, Jose B

    2015-01-10

    Models of protein evolution are used to describe evolutionary processes, for phylogenetic analyses and homology detection. Widely used general models of protein evolution are biased toward globular domains and lack resolution to describe evolutionary processes for other protein types. As three-dimensional structure is a major constraint to protein evolution, specific models have been proposed for other types of proteins. Here, we consider evolutionary patterns in coiled-coil forming proteins. Coiled-coils are widespread structural domains, formed by a repeated motif of seven amino acids (heptad repeat). Coiled-coil forming proteins are frequently rods and spacers, structuring both the intracellular and the extracellular spaces that often form protein interaction interfaces. We tested the hypothesis that due to their specific structure the associated evolutionary constraints differ from those of globular proteins. We showed that substitution patterns in coiled-coil regions are different than those observed in globular regions, beyond the simple heptad repeat. Based on these substitution patterns we developed a coiled-coil specific (CC) model that in the context of phylogenetic reconstruction outperforms general models in tree likelihood, often leading to different topologies. For multidomain proteins containing both a coiled-coil region and a globular domain, we showed that a combination of the CC model and a general one gives higher likelihoods than a single model. Finally, we showed that the model can be used for homology detection to increase search sensitivity for coiled-coil proteins. The CC model, software, and other supplementary materials are available at http://www.evocell.org/cgl/resources (last accessed January 29, 2015). © The Author(s) 2015. Published by Oxford University Press on behalf of the Society for Molecular Biology and Evolution.

  4. Retinal Detachment in Preeclampsia

    Directory of Open Access Journals (Sweden)

    Prado Renata Silva do

    2002-01-01

    Full Text Available Preeclampsia is an obstetric disease of unknown cause that affects approximately 5% of pregnant women. The visual system may be affected with variable intensity, being the retinal detachment a rare complication. The retinal detachment in preeclampsia is usually bilateral and serous, and its pathogenesis is related to the choroidal ischemia secondary to an intense arteriolar vasospasm. The majority of patients have complete recovery of vision with clinical management, and surgery is unnecessary. This is a case report of a 27 year old patient who developed the severe form of preeclampsia on her first pregnancy. She had progressive blurred vision, until she could see only shadows. Ophthalmic examination diagnosed spread and bilateral retinal detachment. With blood pressure control at postpartum, the patient had her retina reattached, and recovery of vision.

  5. Safety detaching hook specification.

    CSIR Research Space (South Africa)

    Roux, JD

    1999-05-01

    Full Text Available Single-sided Impact Tests 14 Appendix C Record of Amendments 15 5. REFERENCES 17 4 1. INTRODUCTION 1.1 Subiect The subject of this specification is safety detaching hooks for mine shaft conveyances. According to South African Law1 it is a legal... after a full detachment in the catch plate or bell. Engineer The Mine Engineer, or his authorised sub-ordinate, legally appointed in terms of an Act to be responsible for shaft equipment. NDE Non-Destructive Examination. OEM Original Equipment...

  6. Retrieval of prolapsed coils during endovascular treatment of cerebral aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Dinc, Hasan [Karadeniz Technical University, Department of Radiology, Faculty of Medicine, Trabzon (Turkey); KTU Farabi Hospital, Department of Radiology, Trabzon (Turkey); Kuzeyli, Kayhan [Karadeniz Technical University, Department of Neurosurgery, Faculty of Medicine, Trabzon (Turkey); Kosucu, Polat; Sari, Ahmet [Karadeniz Technical University, Department of Radiology, Faculty of Medicine, Trabzon (Turkey); Cekirge, Saruhan [Hacettepe University, Department of Radiology, Faculty of Medicine, Ankara (Turkey)

    2006-04-15

    One of the feared complications during detachable coil embolization of cerebral aneurysms is herniation of a coil loop into the parent artery. Although coil protrusion of one or two loops into the parent vessel may not cause adverse events and in some instances can be ignored, the authors believe that coil retrieval is indicated if a free end is seen pulsating along the blood flow stream to prevent migration of the entire coil mass. In one patient, a microballoon was inflated across the neck of the aneurysm during retrieval of a herniated coil to prevent further coil herniation from the aneurysm sac. We present two cases in which prolapsed coils were successfully retrieved either using a microsnare and balloon combination or a microsnare alone. This report focuses on the efficacy of the Amplatz microsnare for such retrievals and the circumstances in which a herniated coil needs to be retrieved. We report two cases in which embolization coils partially migrated into the parent artery during endovascular treatment of cerebral aneurysm and were retrieved using the Amplatz Nitinol microsnare. (orig.)

  7. Programming protein self assembly with coiled coils

    Science.gov (United States)

    Dietz, Hendrik; Bornschlögl, Thomas; Heym, Roland; König, Frauke; Rief, Matthias

    2007-11-01

    The controlled assembly of protein domains into supramolecular structures will be an important prerequisite for the use of functional proteins in future nanotechnology applications. Coiled coils are multimerization motifs whose dimerization properties can be programmed by amino acid sequence. Here, we report programmed supramolecular self-assembly of protein molecules using coiled coils and directly demonstrate its potential on the single molecule level by AFM force spectroscopy. We flanked two different model proteins, Ig27 from human cardiac titin and green fluorescent protein (GFP), by coiled coil binding partners and studied the capability of these elementary building blocks to self-assemble into linear chains. Simple sterical constraints are shown to control the assembly process, providing evidence that many proteins can be assembled with this method. An application for this technique is the design of polyproteins for single molecule force spectroscopy with an integrated force-calibration standard.

  8. Detachable caster adapter

    Science.gov (United States)

    Mohr, R. J.

    1969-01-01

    Detachable caster adapter moves heavy welding tables when fork lift trucks are not practical. A support saddle on the adapter, connected to the caster platform by means of a hinge, fits the leg of the welding table, but can be modified to fit other leg configurations.

  9. Endovascular Treatment of Ruptured Vertebral Dissecting Aneurysms with Electrodetachable Coils

    Directory of Open Access Journals (Sweden)

    Chao-Bao Luo

    2005-12-01

    Conclusion: Endovascular embolization is a useful and safe method in the treatment of ruptured VDAs even when the affected vertebral arteries are dominant or co-dominant in vertebrobasilar flow. Trapping procedures and direct occlusion of the dissecting segment with preservation of the PICA by detachable coils should be performed as early as possible in the management of VDAs.

  10. Spiral versus J-shaped coils for neurovascular embolisation - an in-vitro study

    International Nuclear Information System (INIS)

    Sugiu, K.; Tokunaga, K.; Mandai, S.; Martin, J.B.; Jean, B.; Ruefenacht, D.A.

    2003-01-01

    Our purpose was to compare the characteristics of J-shaped detachable platinum coils with those of spiral coils in in-vitro vascular models. J-shaped coils consist of distal semicircular and proximal straight segments, the latter extending for most of the length of the coil. Spiral coils have a helical shape memory and are thus limited in expansion. In in-vitro silicone vascular models simulating intracranial aneurysms and dural arteriovenous fistulae, we compared J-shaped and spiral coils with regard to ease of delivery, anchoring and folding patterns, and stability in various types of vascular lumen. Delivery and retrieval were comparable. In large and irregular aneurysms and venous sinuses, J-shaped coils could form a more complex basket which conformed to the shape of the vascular cavity. The J-shaped coil was always in contact with the vessel wall. In wide-necked aneurysms, coil protrusion was more frequent with J-shaped coils, while spiral coils tended to stay compact and circular. Arteries were occluded in a shorter segment with spiral coils. J-shaped coils were safe and superior for large and irregular aneurysms or sinuses. Spiral coils were preferable for spherical aneurysms and segmental occlusion of arteries. (orig.)

  11. Pneumatic retinopexy for retinal detachment associated with severe choroidal detachment.

    Science.gov (United States)

    Yeung, Ling; Kokame, Gregg T; Brod, Roy D; Lightman, David A; Lai, James C

    2011-01-01

    The purpose of this study was to evaluate the role of pneumatic retinopexy as an initial management of retinal detachment associated with hypotony, severe choroidal detachment, and vitritis. Retrospective, interventional, noncomparative case series. We included nine eyes from nine patients (six women and three men) with retinal detachment associated with hypotony, severe choroidal detachment, and vitritis managed with pneumatic retinopexy (either SF6 or C3F8) as their initial management between January 1, 1992, and December 31, 2007. Hypotony and choroidal detachment were rapidly and significantly improved 1 to 3 days after pneumatic retinopexy in all patients. The extent of retinal detachment was decreased in five patients. After vitreoretinal surgery for these five patients, all had attached retina. Complete reattachment of the retina was noted in four patients after pneumatic retinopexy. Two of these patients did not require further surgery because the entire retina remained attached at 6 months and 16 months postoperatively. Pneumatic retinopexy is a useful initial procedure in managing retinal detachment associated with hypotony, severe choroidal detachment, and vitritis. By rapidly resolving the hypotony and choroidal detachments, it facilitates subsequent surgical repair of this complicated retinal detachment. In addition, complete retinal reattachment after pneumatic retinopexy alone was initially achieved in 33% of eyes.

  12. Coil Occlusion of the Patent Ductus Arteriosus: Lessons Learned

    International Nuclear Information System (INIS)

    Sanatani, Shubhayan; Potts, James E.; Ryan, Angela; Sandor, George G.S.; Human, Derek G.; Culham, J.A. Gordon

    2000-01-01

    Purpose: To review the clinical outcomes of catheter-directed coil occlusion (coil occlusion) of persistently patent ductus arteriosus (PDA) at a pediatric tertiary care hospital.Methods: A retrospective review of all patients referred to the Cardiac Catheterization Laboratory for coil occlusion at our institution was performed. Twenty-one consecutive patients (12 female) underwent coil occlusion and follow-up between May 1995 and December 1997. We undertook PDA occlusion if: (a) the PDA narrowed to less than 4 mm on echocardiogram and (b) the minimum body weight was approximately 10 kg. Standard right and retrograde left heart catheterization was performed, followed by coil occlusion. Color-flow mapping (CFM) was used intra-procedurally to confirm occlusion of the PDA with a follow-up study several weeks later.Results: The median age and weight of the patients were 33 months and 13.2 kg, respectively. Fourteen patients received one coil, with six requiring a second coil and one requiring multiple coils. Initial follow-up was at a median of 2.4 months. At latest follow-up, 2 patients still have persistent flow at the ductal level. The coils were deployed without complication or embolization.Conclusions: A review of our first 21 cases demonstrated three important lessons: (1) the maximum diameter of the PDA suitable for coil occlusion is approximately 3 mm; (2) CFM must show complete obliteration of flow in the catheterization lab in order to ensure occlusion of the PDA at follow-up; and (3) the Jackson detachable system allows for precise placement of the coil, often within another coil

  13. Between Involvement and Detachment

    DEFF Research Database (Denmark)

    Thomasen, Gry

    stood between the current ‘balanced’ Western Europe and the Europe of the pre-War period. In addition the administration held the opinion that the German problem and the Western European détente tampered with the US unilateralism in its relations with the Soviet Union, and its position as the leader....... Thus the US proposed the Harmel formula before Harmel. In general, the developments in Western Europe put the Johnson administration in a state of alarm, and the European allies therefore had a larger impact on America’s policies, except in the essentially detached nuclear policy, which...

  14. Biomaterials Made from Coiled-Coil Peptides.

    Science.gov (United States)

    Conticello, Vincent; Hughes, Spencer; Modlin, Charles

    The development of biomaterials designed for specific applications is an important objective in personalized medicine. While the breadth and prominence of biomaterials have increased exponentially over the past decades, critical challenges remain to be addressed, particularly in the development of biomaterials that exhibit highly specific functions. These functional properties are often encoded within the molecular structure of the component molecules. Proteins, as a consequence of their structural specificity, represent useful substrates for the construction of functional biomaterials through rational design. This chapter provides an in-depth survey of biomaterials constructed from coiled-coils, one of the best-understood protein structural motifs. We discuss the utility of this structurally diverse and functionally tunable class of proteins for the creation of novel biomaterials. This discussion illustrates the progress that has been made in the development of coiled-coil biomaterials by showcasing studies that bridge the gap between the academic science and potential technological impact.

  15. Cooling and dehumidifying coils

    International Nuclear Information System (INIS)

    Murthy, M.V.K.

    1988-01-01

    The operating features of cooling and dehumidifying coils and their constructional details are discussed. The heat transfer relations as applicable to the boiling refrigerant and a single phase fluid are presented. Methods of accounting for the effect of moisture condensation on the air side heat transfer coefficient and the fin effectiveness are explained. The logic flow necessary to analyze direct expansion coils and chilled water coils is discussed

  16. Paediatric retinal detachment: a review

    Directory of Open Access Journals (Sweden)

    Raffaele Nuzzi

    2017-10-01

    Full Text Available Paediatric retinal detachment (PRD is an uncommon and challenging disease; it differs from adult detachments in etiology, anatomical characteristics, management and prognosis. PRDs can be particularly challenging, even for the most expert paediatric surgeons due to the higher prevalence of total retinal detachments, late diagnosis and bilateral involvement with respect to those which occur in adulthood. Moreover, the anatomical success, when achieved, is frequently not related to a functional recover. Postsurgical adverse events, refractive errors and amblyopia may additionally undermine the final outcome. Up to date there are few reviews regarding the approach of retinal detachment in children, mainly dealing with rhegmatogenous retinal detachment. In this review, rhegmatogenous, retinopathy of prematurity-related and Coats’-related PRDs were considered. The available literature from the last decades were reviewed and summarized. Epidemiology, etiology and clinical presentation, together with therapeutic approaches and outcomes have been reviewed and discussed.

  17. [Prophylactic treatment of retinal detachment].

    Science.gov (United States)

    Binder, S; Riss, B

    1981-08-01

    The indications for and results of prophylactic treatment of retinal detachment during a period of five years are reported and compared with the results in the literature. Half of the cases (3 out of 6 eyes) which developed a retinal detachment had been horse-shoe tears combined with a vitreous hemorrhage. For this reason a small buckle operation is recommended in these cases, to prevent further traction. Lattice degeneration should rather be observed than treated, except in special cases: This includes eyes where the fellow eye had a detachment from a lattice degeneration, cases in which one eye is blind from an uncured detachment or has no useful visual acuity, and eyes whose fellow eye has giant tears. In aphakic eyes treatment of lattice degeneration is recommended, because the incidence of detachment from these areas is high, especially in young aphakic cases. In one aphakic eye which had been photocoagulated several times the formation of a preretinal membrane was observed.

  18. The coiled coil motif in polymer drug delivery systems.

    Science.gov (United States)

    Pechar, Michal; Pola, Robert

    2013-01-01

    The coiled coil is a superhelical structural protein motif that has been thoroughly investigated in recent years. Because of the relatively well-understood principles that determine the properties of coiled coil peptides and proteins, macromolecular systems containing the coiled coil motif have been suggested for various applications. This short review focuses on hybrid polymer coiled coil systems designed for drug delivery purposes. After a short introduction, the most important features of the coiled coils (stability, association number, oligomerization selectivity and orientation of helices) are described, and the factors influencing these characteristics are discussed. Several examples of the most interesting biomedical applications of the polymer-coiled coil systems (according to the authors' opinion) are presented. Copyright © 2011 Elsevier Inc. All rights reserved.

  19. Compact stellarator coils

    International Nuclear Information System (INIS)

    Pomphrey, N.; Berry, L.A.; Boozer, A.H.

    2001-01-01

    Experimental devices to study the physics of high-beta (β>∼4%), low aspect ratio (A<∼4.5) stellarator plasmas require coils that will produce plasmas satisfying a set of physics goals, provide experimental flexibility, and be practical to construct. In the course of designing a flexible coil set for the National Compact Stellarator Experiment, we have made several innovations that may be useful in future stellarator design efforts. These include: the use of Singular Value Decomposition methods for obtaining families of smooth current potentials on distant coil winding surfaces from which low current density solutions may be identified; the use of a Control Matrix Method for identifying which few of the many detailed elements of the stellarator boundary must be targeted if a coil set is to provide fields to control the essential physics of the plasma; the use of Genetic Algorithms for choosing an optimal set of discrete coils from a continuum of potential contours; the evaluation of alternate coil topologies for balancing the tradeoff between physics objective and engineering constraints; the development of a new coil optimization code for designing modular coils, and the identification of a 'natural' basis for describing current sheet distributions. (author)

  20. Liquid rope coiling

    NARCIS (Netherlands)

    Ribe, N.M.; Habibi, M.; Bonn, D.

    2012-01-01

    A thin stream or rope of viscous fluid falling from a sufficient height onto a surface forms a steadily rotating helical coil. Tabletop laboratory experiments in combination with a numerical model for slender liquid ropes reveal that finite-amplitude coiling can occur in four distinct regimes

  1. Molecular basis of coiled-coil oligomerization-state specificity.

    Science.gov (United States)

    Ciani, Barbara; Bjelic, Saša; Honnappa, Srinivas; Jawhari, Hatim; Jaussi, Rolf; Payapilly, Aishwarya; Jowitt, Thomas; Steinmetz, Michel O; Kammerer, Richard A

    2010-11-16

    Coiled coils are extensively and successfully used nowadays to rationally design multistranded structures for applications, including basic research, biotechnology, nanotechnology, materials science, and medicine. The wide range of applications as well as the important functions these structures play in almost all biological processes highlight the need for a detailed understanding of the factors that control coiled-coil folding and oligomerization. Here, we address the important and unresolved question why the presence of particular oligomerization-state determinants within a coiled coil does frequently not correlate with its topology. We found an unexpected, general link between coiled-coil oligomerization-state specificity and trigger sequences, elements that are indispensable for coiled-coil formation. By using the archetype coiled-coil domain of the yeast transcriptional activator GCN4 as a model system, we show that well-established trimer-specific oligomerization-state determinants switch the peptide's topology from a dimer to a trimer only when inserted into the trigger sequence. We successfully confirmed our results in two other, unrelated coiled-coil dimers, ATF1 and cortexillin-1. We furthermore show that multiple topology determinants can coexist in the same trigger sequence, revealing a delicate balance of the resulting oligomerization state by position-dependent forces. Our experimental results should significantly improve the prediction of the oligomerization state of coiled coils. They therefore should have major implications for the rational design of coiled coils and consequently many applications using these popular oligomerization domains.

  2. Divertor coil device

    International Nuclear Information System (INIS)

    Hanai, Satoru.

    1990-01-01

    The present invention concerns a divertor coil device used in a tokamak type thermonuclear device and the object thereof is to reduce thermal loads in the heat receiving portion. An auxiliary power source is disposed, in addition to a main power source, for supplying main electric current for changing electric current ratio between each of the divertor coils. Then, the null point for forming plasmas is made controllable. As a result, a power source for a part of coils connected to the auxiliary power source of the divertor coils can be changed by controlling the voltage of the auxiliary power source. Accordingly, the electric current distribution in the divertor coils is changed and the position for the null point high thermal load region can be moved laterally. The area of the heat receiving portion can be increased by moving the high thermal load region, thereby decreasing the thermal load density. (I.S.)

  3. Drusenoid retinal pigment epithelium detachments

    Directory of Open Access Journals (Sweden)

    Miguel Hage Amaro

    2015-10-01

    Full Text Available ABSTRACT The authors make a review of drusenoid retinal pigment epithelium detachments(DPDs, a form of retinal pigment epithelium detachment(PED that evolves from confluent and large soft drusen.Drusenoidretinal pigment epithelial detachments are a recognized element of the "dry" AMD. Until now, no treatment is indicated in drusenoid PEDs. The authors describe the clinical characteristics of drusenoid retinal pigment epithelium detachments (DPEDs and make a review of the DPEDs related in the international literature. We related in this revision paper the multimodal advanced image exams in two cases of dusenoid retinal pigment epithelium detachments (DPEDs and the general characteristics of thisfinding associated with Dry Macular degeneration.Upon examination of the ocular fundusDPEDs emerge as well-circumscribed yellow or yellow–white elevations of the RPE that are usually found within the macula.They may show scalloped borders and a slightly irregular surface. When visualized using fluorescein angiography (FA,DPEDs are typically described as faint hyper-fluorescent in the early phase followed by a slow increase in fluorescence throughout the transit stage of the study without late leakage. With optical coherence tomography (OCT, drusenoid PEDs usually show a smooth contour of the detached hyperreflective RPE band that may have an undulating appearance.Drusenoid PEDs encompass far above the ground possibility type of "dry" AMD that develops in relationship with large confluent soft drusen.At this point no treatment is utilized in drusenoid retinal pigment epithelium detachment(DPEDs.

  4. Shock detachment from curved wedges

    Science.gov (United States)

    Mölder, S.

    2017-09-01

    Curved shock theory is used to show that the flow behind attached shocks on doubly curved wedges can have either positive or negative post-shock pressure gradients depending on the freestream Mach number, the wedge angle and the two wedge curvatures. Given enough wedge length, the flow near the leading edge can choke to force the shock to detach from the wedge. This local choking can preempt both the maximum deflection and the sonic criteria for shock detachment. Analytical predictions for detachment by local choking are supported by CFD results.

  5. Open coil traction system.

    Science.gov (United States)

    Vibhute, Pavankumar Janardan

    2012-01-01

    Sliding mechanics have become a popular method for space closure, with the development of preadjusted edgewise appliances. Furthermore, various space closing auxiliaries have been developed and extensively evaluated for their clinical efficiency. Their effectiveness is enhanced with optimum force magnitude and low load deflection rate/force decay. With the advent of nickel-titanium (Ni-Ti) springs in orthodontics, load deflection rates have been markedly reduced. To use Ni-Ti springs, clinicians have to depend upon prefabricated closed coil springs. The open coil traction system, or open coil retraction spring, is developed utilizing Ni-Ti open coil springs for orthodontic space closure. This article describes the fabrication and clinical application of the open coil traction system, which has a number of advantages. It sustains a low load deflection rate with optimum force magnitude, and its design is adjustable for a desired length and force level. It is fail-safe for both activation and deactivation (ie, it cannot be overactivated, and the decompression limit of the open coil is controlled by the operator). The open coil traction system can be offset from the mucosa to help reduce soft tissue impingement.

  6. Commercial applications for COIL

    Science.gov (United States)

    Solomon, Wayne C.; Carroll, David L.; King, D. M.; Fockler, L. A.; Stromberg, D. S.; Sexauer, M.; Milmoe, A.; Sentman, Lee H.

    2000-01-01

    The chemical oxygen-iodine laser (COIL) is a high power, fiber deliverable tool, which can be used for a number of different industrial applications. COIL is of particular interest because of its short fiber deliverable wavelength, high scaleable continuous wave power, and excellent material interaction properties. In past research the University of Illinois at Urbana-Champaign identified and decommissioning and decontamination (DD) of nuclear facilities as a primary focus for COIL technology. DD will be a major challenge in the coming decades. The use of a robotically driven fiber delivered cutting/ablation tool in contaminated areas promises to lower risks to workers for the DD mission. Further, the high cutting speed of COIL will significantly reduce the time required to cut contaminated equipment, reducing costs. The high power of COIL will permit the dismantling of thick stacks of piping and equipment as well as reactor vessels. COIL is very promising for the removal of material from contaminated surfaces, perhaps to depths thicker than an inch. Laser cutting and ablation minimizes dust and fumes, which reduces the required number of high efficiency particulate accumulator filters, thus reducing costly waste disposal. Other potential industrial applications for COIL are shipbuilding, automotive manufacturing, heavy machinery manufacturing, tasks requiring underwater cutting or welding, and there appear to be very promising applications for high powers lasers in the oil industry.

  7. Coil spring venting arrangement

    International Nuclear Information System (INIS)

    McCugh, R.M.

    1975-01-01

    A simple venting device for trapped gas pockets in hydraulic systems is inserted through a small access passages, operated remotely, and removed completely. The device comprises a small diameter, closely wound coil spring which is pushed through a guide temporarily inserted in the access passage. The guide has a central passageway which directs the coil spring radially upward into the pocket, so that, with the guide properly positioned for depth and properly oriented, the coil spring can be pushed up into the top of the pocket to vent it. By positioning a seal around the free end of the guide, the spring and guide are removed and the passage is sealed

  8. Coiled-coils: The long and short of it.

    Science.gov (United States)

    Truebestein, Linda; Leonard, Thomas A

    2016-09-01

    Coiled-coils are found in proteins throughout all three kingdoms of life. Coiled-coil domains of some proteins are almost invariant in sequence and length, betraying a structural and functional role for amino acids along the entire length of the coiled-coil. Other coiled-coils are divergent in sequence, but conserved in length, thereby functioning as molecular spacers. In this capacity, coiled-coil proteins influence the architecture of organelles such as centrioles and the Golgi, as well as permit the tethering of transport vesicles. Specialized coiled-coils, such as those found in motor proteins, are capable of propagating conformational changes along their length that regulate cargo binding and motor processivity. Coiled-coil domains have also been identified in enzymes, where they function as molecular rulers, positioning catalytic activities at fixed distances. Finally, while coiled-coils have been extensively discussed for their potential to nucleate and scaffold large macromolecular complexes, structural evidence to substantiate this claim is relatively scarce. © 2016 The Authors BioEssays Published by WILEY Periodicals, Inc.

  9. Extending the self-assembly of coiled-coil hybrids

    NARCIS (Netherlands)

    Robson Marsden, Hana

    2009-01-01

    Of the various biomolecular building blocks in use in nature, coiled-coil forming peptides are amongst those with the most potential as building blocks for the synthetic self-assembly of nanostructures. Native coiled coils have the ability to function in, and influence, complex systems composed of

  10. Disruption of Bcr-Abl coiled coil oligomerization by design.

    Science.gov (United States)

    Dixon, Andrew S; Pendley, Scott S; Bruno, Benjamin J; Woessner, David W; Shimpi, Adrian A; Cheatham, Thomas E; Lim, Carol S

    2011-08-05

    Oligomerization is an important regulatory mechanism for many proteins, including oncoproteins and other pathogenic proteins. The oncoprotein Bcr-Abl relies on oligomerization via its coiled coil domain for its kinase activity, suggesting that a designed coiled coil domain with enhanced binding to Bcr-Abl and reduced self-oligomerization would be therapeutically useful. Key mutations in the coiled coil domain of Bcr-Abl were identified that reduce homo-oligomerization through intermolecular charge-charge repulsion yet increase interaction with the Bcr-Abl coiled coil through additional salt bridges, resulting in an enhanced ability to disrupt the oligomeric state of Bcr-Abl. The mutations were modeled computationally to optimize the design. Assays performed in vitro confirmed the validity and functionality of the optimal mutations, which were found to exhibit reduced homo-oligomerization and increased binding to the Bcr-Abl coiled coil domain. Introduction of the mutant coiled coil into K562 cells resulted in decreased phosphorylation of Bcr-Abl, reduced cell proliferation, and increased caspase-3/7 activity and DNA segmentation. Importantly, the mutant coiled coil domain was more efficacious than the wild type in all experiments performed. The improved inhibition of Bcr-Abl through oligomeric disruption resulting from this modified coiled coil domain represents a viable alternative to small molecule inhibitors for therapeutic intervention.

  11. Transcatheter coil occluder for closure of ventricular septal defect (a report of 4 cases)

    International Nuclear Information System (INIS)

    Gao Wei; Zhou Aiqing; Yu Zhiqing; Li Fen; Zhong Yumin; Zhang Yuqi; Huang Meirong; Sun Kun

    2005-01-01

    Objective: To explore the indication, methodology and complication of transcatheter coil closure of ventricular septal defect (VSD) in children. Methods: Transcatheter closure of perimembranous VSD with coils was performed in 4 cases from 2003 to 2005. The Duct-Occlude (pfm) and detachable coil (Cook) were chosen for embolization depending on the results of the left ventricular angiogram. The coil size was generally about 1-4 mm larger than the diameter of VSD. Follow up was carried out with echocardiography, ultrasound and clinical examination. Results: The defect diameters of the four cases were 2.0 mm, 2.7 mm, 2.5 mm and 1.5 mm respectively. The Duct-Occlude were successfully implanted in 3 cases of perimembranous VSD with the same type coil (OD[mm]7-3-6, windings 5-3-4) for each. One detachable coil (Cook) (5 x 5) was implanted in the remaining case. All cases had trivial residual shunt immediately after implantation which disappeared 24 hours later. Follow-up for 2 months to one year showed no coil displacement and secondary bacterial arteritis. No tricuspid and aortic regurgitation, no emboli, no endocarditis, and no arrhythmia were found. Conclusions: Coil closure of some small VSD with membranate part pseudo-ventricular aneurysm has good efficacy with the advantages of simple operation, less metal content and mini-invasion also applicable for infants. (authors)

  12. A periodic table of coiled-coil protein structures.

    Science.gov (United States)

    Moutevelis, Efrosini; Woolfson, Derek N

    2009-01-23

    Coiled coils are protein structure domains with two or more alpha-helices packed together via interlacing of side chains known as knob-into-hole packing. We analysed and classified a large set of coiled-coil structures using a combination of automated and manual methods. This led to a systematic classification that we termed a "periodic table of coiled coils," which we have made available at http://coiledcoils.chm.bris.ac.uk/ccplus/search/periodic_table. In this table, coiled-coil assemblies are arranged in columns with increasing numbers of alpha-helices and in rows of increased complexity. The table provides a framework for understanding possibilities in and limits on coiled-coil structures and a basis for future prediction, engineering and design studies.

  13. Borehole induction coil transmitter

    Science.gov (United States)

    Holladay, Gale; Wilt, Michael J.

    2002-01-01

    A borehole induction coil transmitter which is a part of a cross-borehole electromagnetic field system that is used for underground imaging applications. The transmitter consists of four major parts: 1) a wound ferrite or mu-metal core, 2) an array of tuning capacitors, 3) a current driver circuit board, and 4) a flux monitor. The core is wound with several hundred turns of wire and connected in series with the capacitor array, to produce a tuned coil. This tuned coil uses internal circuitry to generate sinusoidal signals that are transmitted through the earth to a receiver coil in another borehole. The transmitter can operate at frequencies from 1-200 kHz and supplies sufficient power to permit the field system to operate in boreholes separated by up to 400 meters.

  14. LHC bending magnet coil

    CERN Multimedia

    A short test version of coil of wire used for the LHC dipole magnets. The high magnetic fields needed for guiding particles around the Large Hadron Collider (LHC) ring are created by passing 12’500 amps of current through coils of superconducting wiring. At very low temperatures, superconductors have no electrical resistance and therefore no power loss. The LHC is the largest superconducting installation ever built. The magnetic field must also be extremely uniform. This means the current flowing in the coils has to be very precisely controlled. Indeed, nowhere before has such precision been achieved at such high currents. Magnet coils are made of copper-clad niobium–titanium cables — each wire in the cable consists of 9’000 niobium–titanium filaments ten times finer than a hair.

  15. LHCb magnet coils arrive

    CERN Multimedia

    Maximilien Brice

    2003-01-01

    Each of the two coils for the LHCb magnet comprises 15 individual monolayer 'pancakes' of identical trapezoidal racetrack shape, and is bent at 45 degrees on the two transverse sides. Each pancake consists of eight turns of conductor, wound from a single length (approx. 290 m) of extruded aluminium. The coils have arrived at CERN; one of them is seen here being unloaded above the LHCb experimental cavern.

  16. Controlling marginally detached divertor plasmas

    Science.gov (United States)

    Eldon, D.; Kolemen, E.; Barton, J. L.; Briesemeister, A. R.; Humphreys, D. A.; Leonard, A. W.; Maingi, R.; Makowski, M. A.; McLean, A. G.; Moser, A. L.; Stangeby, P. C.

    2017-06-01

    A new control system at DIII-D has stabilized the inter-ELM detached divertor plasma state for H-mode in close proximity to the threshold for reattachment, thus demonstrating the ability to maintain detachment with minimal gas puffing. When the same control system was instead ordered to hold the plasma at the threshold (here defined as T e  =  5 eV near the divertor target plate), the resulting T e profiles separated into two groups with one group consistent with marginal detachment, and the other with marginal attachment. The plasma dithers between the attached and detached states when the control system attempts to hold at the threshold. The control system is upgraded from the one described in Kolemen et al (2015 J. Nucl. Mater. 463 1186) and it handles ELMing plasmas by using real time D α measurements to remove during-ELM slices from real time T e measurements derived from divertor Thomson scattering. The difference between measured and requested inter-ELM T e is passed to a PID (proportional-integral-derivative) controller to determine gas puff commands. While some degree of detachment is essential for the health of ITER’s divertor, more deeply detached plasmas have greater radiative losses and, at the extreme, confinement degradation, making it desirable to limit detachment to the minimum level needed to protect the target plate (Kolemen et al 2015 J. Nucl. Mater. 463 1186). However, the observed bifurcation in plasma conditions at the outer strike point with the ion B   ×  \

  17. Retinal Detachment Associated With Atopic Dermatitis.

    Science.gov (United States)

    Kothari, Nikisha; Young, Ryan C; Read, Sarah P; Tutiven, Jacqueline; Perez, Victor L; Flynn, Harry W; Berrocal, Audina M

    2017-06-01

    Ocular manifestations related to atopic dermatitis include keratoconus, keratoconjunctivitis, cataract, and retinal detachment. The authors report three cases of retinal detachment associated with atopic dermatitis. Although the pathogenesis is poorly understood, chronic blunt trauma may play a role in the development of retinal detachment. In addition, retinal detachments associated with atopic dermatitis may have lower rates of successful retinal detachment repair. [Ophthalmic Surg Lasers Imaging Retina. 2017;48:513-517.]. Copyright 2017, SLACK Incorporated.

  18. Coil protection calculator for TFTR

    International Nuclear Information System (INIS)

    Marsala, R.J.; Woolley, R.D.

    1987-01-01

    A new coil protection calculator (CPC) is presented in this paper. It is now being developed for TFTR's magnetic field coils will replace the existing coil fault detector. The existing fault detector sacrifices TFTR operating capability for simplicity. The new CPC will permit operation up to the actual coil limits by accurately and continuously computing coil parameters in real-time. The improvement will allow TFTR to operate with higher plasma currents and will permit the optimization of pulse repetition rates

  19. Hierarchical cascades of instability govern the mechanics of coiled coils: helix unfolding precedes coil unzipping.

    Science.gov (United States)

    Hamed, Elham; Keten, Sinan

    2014-07-15

    Coiled coils are a fundamental emergent motif in proteins found in structural biomaterials, consisting of α-helical secondary structures wrapped in a supercoil. A fundamental question regarding the thermal and mechanical stability of coiled coils in extreme environments is the sequence of events leading to the disassembly of individual oligomers from the universal coiled-coil motifs. To shed light on this phenomenon, here we report atomistic simulations of a trimeric coiled coil in an explicit water solvent and investigate the mechanisms underlying helix unfolding and coil unzipping in the assembly. We employ advanced sampling techniques involving steered molecular dynamics and metadynamics simulations to obtain the free-energy landscapes of single-strand unfolding and unzipping in a three-stranded assembly. Our comparative analysis of the free-energy landscapes of instability pathways shows that coil unzipping is a sequential process involving multiple intermediates. At each intermediate state, one heptad repeat of the coiled coil first unfolds and then unzips due to the loss of contacts with the hydrophobic core. This observation suggests that helix unfolding facilitates the initiation of coiled-coil disassembly, which is confirmed by our 2D metadynamics simulations showing that unzipping of one strand requires less energy in the unfolded state compared with the folded state. Our results explain recent experimental findings and lay the groundwork for studying the hierarchical molecular mechanisms that underpin the thermomechanical stability/instability of coiled coils and similar protein assemblies. Copyright © 2014 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  20. Performance of long J-shaped coils in large and giant intracranial aneurysms: an in vitro study

    International Nuclear Information System (INIS)

    Tokunaga, K.; Tanaka, N.; Sugiu, K.; Levrier, O.; Martin, J.B.; Ruefenacht, D.A.

    2002-01-01

    We evaluated the performance of long straight coils (Detach-18 trademark J-shaped coils) in large and giant in-vitro aneurysms. The coils consisted of a distal semicircular part 7 or 15 mm in diameter and a proximal 70 cm straight part having three types of stiffness: soft, standard, and stiff. We first investigated the ease of passage through a microcatheter in a realistic cerebral vessel model. Second, we made silicone models simulating lateral-type aneurysms of various spherical dome diameters (12, 15, 20 and 30 mm) and neck sizes (3-10 mm; dome-to-neck ratio approximately 3:1) and connected them to a pulsating circulatory pump. We evaluated the anchoring and folding patterns of the coils, stability of the microcatheter and coils in the aneurysm, and smoothness of delivery and retrieval of coils. Third, we compared the conformability of a coil in a large, irregular aneurysm with that of a spiral coil. The long J-shaped coils were easily advanced and retrieved through a microcatheter in a tortuous vessel model. In 12 mm spherical aneurysms, each coil made a complex framework, and knot formation or damage to the coil during withdrawal was often observed. In 15 mm aneurysms, the coils were all easily delivered and retrieved; standard-stiffness coils adapted best to this size. In 20 mm aneurysms, frameworks were less complex but still good with a standard or stiff coil, but those with soft coil were unstable and changed significantly within 3 min of detachment due to gravity and pulsatile flow. In 30 mm aneurysms, soft coils filled only the lower part during introduction, whereas a stiff coil still made a favourable framework. Conformability of a long J-shaped coil was superior to that of a spiral coil in a large, irregular aneurysm. Long J-shaped coils conform well to various configurations of large and giant aneurysms and can shorten procedures since a larger implant volume can be delivered with a single coil. Their principle of action may promote more favourable

  1. AAFreqCoil: a new classifier to distinguish parallel dimeric and trimeric coiled coils.

    Science.gov (United States)

    Wang, Xiaofeng; Zhou, Yuan; Yan, Renxiang

    2015-07-01

    Coiled coils are characteristic rope-like protein structures, constituted by one or more heptad repeats. Native coiled-coil structures play important roles in various biological processes, while the designed ones are widely employed in medicine and industry. To date, two major oligomeric states (i.e. dimeric and trimeric states) of a coiled-coil structure have been observed, plausibly exerting different biological functions. Therefore, exploration of the relationship between heptad repeat sequences and coiled coil structures is highly important. In this paper, we develop a new method named AAFreqCoil to classify parallel dimeric and trimeric coiled coils. Our method demonstrated its competitive performance when benchmarked based on 10-fold cross validation and jackknife cross validation. Meanwhile, the rules that can explicitly explain the prediction results of the test coiled coil can be extracted from the AAFreqCoil model for a better explanation of user predictions. A web server and stand-alone program implementing the AAFreqCoil algorithm are freely available at .

  2. Superconducting coil protection

    International Nuclear Information System (INIS)

    Woods, E.L.

    1975-01-01

    The protection system is based on a two-phase construction program. Phase I is the development of a reliable hardwired relay control system with a digital loop utilizing firmware and a microprocessor controller. Phase II is an expansion of the digital loop to include many heretofore unmonitored coil variables. These new monitored variables will be utilized to establish early quench detection and to formulate confirmation techniques of the quench detection mechanism. Established quench detection methods are discussed and a new approach to quench detection is presented. The new circuit is insensitive to external pulsed magnetic fields and the associated induced voltages. Reliability aspects of the coil protection system are discussed with respect to shutdowns of superconducting coil systems. Redundance and digital system methods are presented as related topics

  3. TESLA Coil Research

    Science.gov (United States)

    1992-05-01

    Sloan’s work was actually predated by the earlier work of Nikola Tesla . Sloan mistakenly identified " Tesla Coils" as lumped tuned resonators. The...Lefvw WsnJ L REPORT o]i 3. REPRT TYPE AND OATES COVEIRD May 1992 Special/Aug 1992 - May 1992 Z TITLE AND 5U§nUT S. FUNDING NUMIHRS Tesla Coil Research...STATEMENT 1211. ’ISTRIUUTION COOD Approved for public release; dis~ribution is unlimited 13. ABSTRACT (Masrmum 200 worw) High repetition rate Tesla

  4. Meiosis specific coiled-coil proteins in Shizosaccharomyces pombe

    Directory of Open Access Journals (Sweden)

    Okuzaki Daisuke

    2007-05-01

    Full Text Available Abstract Many meiosis-specific proteins in Schizosaccharomyces pombe contain coiled-coil motifs which play essential roles for meiotic progression. For example, the coiled-coil motifs present in Meu13 and Mcp7 are required for their function as a putative recombinase cofactor complex during meiotic recombination. Mcp6/Hrs1 and Mcp5/Num1 control horsetail chromosome movement by astral microtubule organization and anchoring dynein respectively. Dhc1 and Ssm4 are also required for horsetail chromosome movement. It is clear from these examples that the coiled-coil motif in these proteins plays an important role during the progression of cells through meiosis. However, there are still many unanswered questions on how these proteins operate. In this paper, we briefly review recent studies on the meiotic coiled-coil proteins in Sz. pombe.

  5. NET model coil test possibilities

    International Nuclear Information System (INIS)

    Erb, J.; Gruenhagen, A.; Herz, W.; Jentzsch, K.; Komarek, P.; Lotz, E.; Malang, S.; Maurer, W.; Noether, G.; Ulbricht, A.; Vogt, A.; Zahn, G.; Horvath, I.; Kwasnitza, K.; Marinucci, C.; Pasztor, G.; Sborchia, C.; Weymuth, P.; Peters, A.; Roeterdink, A.

    1987-11-01

    A single full size coil for NET/INTOR represents an investment of the order of 40 MUC (Million Unit Costs). Before such an amount of money or even more for the 16 TF coils is invested as much risks as possible must be eliminated by a comprehensive development programme. In the course of such a programme a coil technology verification test should finally prove the feasibility of NET/INTOR TF coils. This study report is almost exclusively dealing with such a verification test by model coil testing. These coils will be built out of two Nb 3 Sn-conductors based on two concepts already under development and investigation. Two possible coil arrangements are discussed: A cluster facility, where two model coils out of the two Nb 3 TF-conductors are used, and the already tested LCT-coils producing a background field. A solenoid arrangement, where in addition to the two TF model coils another model coil out of a PF-conductor for the central PF-coils of NET/INTOR is used instead of LCT background coils. Technical advantages and disadvantages are worked out in order to compare and judge both facilities. Costs estimates and the time schedules broaden the base for a decision about the realisation of such a facility. (orig.) [de

  6. The mechanics of retinal detachment

    Science.gov (United States)

    Chou, Tom; Siegel, Michael

    2013-03-01

    We present a model of the mechanical and fluid forces associated with exudative retinal detachments where the retinal photoreceptor cells separate typically from the underlying retinal pigment epithelium (RPE). By computing the total fluid volume flow arising from transretinal, vascular, and retinal pigment epithelium (RPE) pump currents, we determine the conditions under which the subretinal fluid pressure exceeds the maximum yield stress holding the retina and RPE together, giving rise to an irreversible, extended retinal delamination. We also investigate localized, blister-like retinal detachments by balancing mechanical tension in the retina with both the retina-RPE adhesion energy and the hydraulic pressure jump across the retina. For detachments induced by traction forces, we find a critical radius beyond which the blister is unstable to growth. Growth of a detached blister can also be driven by inflamed tissue within which e.g., the hydraulic conductivities of the retina or choroid increase, the RPE pumps fail, or the adhesion properties change. We determine the parameter regimes in which the blister either becomes unstable to growth, remains stable and finite-sized, or shrinks, allowing possible healing. This work supported by the Army Research Office through grant 58386MA

  7. Retinal detachment in paediatric patients

    International Nuclear Information System (INIS)

    Zafar, S. N.; Qureshi, N.; Azad, N.; Khan, A.

    2013-01-01

    Objective: To assess the causes of retinal detachment in children and the various operative procedures requiring vitreoretinal surgical intervention for the same. Study Design: Case series. Place and Duration of Study: Department of Ophthalmology, Al-Shifa Trust Eye Hospital, Rawalpindi, from January 2006 to May 2009. Methodology: A total of 281 eyes of 258 patients, (aged 0 - 18 years) who underwent vitreo-retinal surgical intervention for retinal detachment were included. Surgical log was searched for the type of retinal detachment and its causes. Frequencies of various interventions done in these patients viz. vitrectomy, scleral buckle, use of tamponading agents, laser photocoagulation and cryotherapy were noted. Results were described as descriptive statistics. Results: Myopia was the cause in 62 (22.1%) and trauma in 51 (18.1%) of the eyes. Total retinal detachment (RD) was treated in 94 (33.5%) eyes, sub total RD in 36 (12.8%), recurrent RD in 32 (11.4%), giant retinal tear in 28 (10%), tractional RD in 15 (5.3%) and exudative RD in 2 (0.7%). Prophylactic laser or cryotherapy was applied in 74 (26.3%) of the eyes. Pars plana vitrectomy (PPV) was carried out in 159 (56.6%) eyes while scleral buckle procedure was done in 129 (45.9%) eyes. Silicon oil was used in 149 (53%), perfluorocarbon liquid in 32 (11.4%) and gas tamponade in 20 (7.1%) eyes. Conclusion: The most common cause of retinal detachment in paediatric patients was myopia, followed by trauma. Total RD was more common as compared to the other types. The most common procedure adopted was pars plana vitrectomy followed by scleral buckle procedure. (author)

  8. Kinematic Fitting of Detached Vertices

    Energy Technology Data Exchange (ETDEWEB)

    Mattione, Paul [Rice Univ., Houston, TX (United States)

    2007-05-01

    The eg3 experiment at the Jefferson Lab CLAS detector aims to determine the existence of the $\\Xi_{5}$ pentaquarks and investigate the excited $\\Xi$ states. Specifically, the exotic $\\Xi_{5}^{--}$ pentaquark will be sought by first reconstructing the $\\Xi^{-}$ particle through its weak decays, $\\Xi^{-}\\to\\pi^{-}\\Lambda$ and $\\Lambda\\to\\pi^{-}$. A kinematic fitting routine was developed to reconstruct the detached vertices of these decays, where confidence level cuts on the fits are used to remove background events. Prior to fitting these decays, the exclusive reaction $\\gamma D\\rightarrow pp\\pi^{-}$ was studied in order to correct the track measurements and covariance matrices of the charged particles. The $\\Lambda\\rightarrow p\\pi^{-}$ and $\\Xi^{-}\\to\\pi^{-}\\Lambda$ decays were then investigated to demonstrate that the kinematic fitting routine reconstructs the decaying particles and their detached vertices correctly.

  9. Use of a Hydrogel-Coated Self-Expandable Coil to Salvage a Failed Transcatheter Embolization of a Mesenteric Hemorrhage

    International Nuclear Information System (INIS)

    Bui, James T.; West, Derek L.; Pai, Rajiv; Owens, Charles A.

    2006-01-01

    HydroCoil (MicroVention, Aliso Viejo, CA, USA) is a self-expanding detachable coil developed to improve the endovascular occlusion of intracranial aneurysms. The hydrogel polymer covering the microcoil expands to several times its original diameter to enhance thrombosis of the intended vessel. We made use of this new technology to occlude a mesenteric artery pseudoaneurysm that failed superselective embolization with standard microcoils

  10. Intravascular placement of metallic coils as lung tumor markers for CyberKnife stereotactic radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Karaman, Kutlay; Dokdok, A. Murat; Karadeniz, Okatay; Ceylan, Cemile; Engin, Kayihan [Anadolu Medical Center, Kocaeli (Turkey)

    2015-06-15

    To present our experience with placing endovascular coils in pulmonary arteries used as a fiducial marker for CyberKnife therapy and to describe the technical details and complications of the procedure. Between June 2005 and September 2013, 163 patients with primary or secondary lung malignancies, referred for fiducial placement for stereotactic radiosurgery, were retrospectively reviewed. Fourteen patients (9 men, 5 women; mean age, 70 years) with a history of pneumonectomy (n = 3), lobectomy (n = 3) or with severe cardiopulmonary co-morbidity (n = 8) underwent coil (fiducial marker) placement. Pushable or detachable platinum micro coils (n = 49) 2-3 mm in size were inserted through coaxial microcatheters into a small distal pulmonary artery in the vicinity of the tumor under biplane angiography/fluoroscopy guidance. Forty nine coils with a median number of 3 coils per tumor were placed with a mean tumor-coil distance of 2.7 cm. Forty three (87.7%) of 49 coils were successfully used as fiducial markers. Two coils could not be used due to a larger tumor-coil distance (> 50 mm). Four coils were in an acceptable position but their non-coiling shape precluded tumor tracking for CyberKnife treatment. No major complications needing further medication other than nominal therapy, hospitalization more than one night or permanent adverse sequale were observed. Endovascular placement of coil as a fiducial marker is safe and feasible during CyberKnife therapy, and might be an option for the patients in which percutaneous transthoracic fiducial placement might be risky.

  11. Intravascular placement of metallic coils as lung tumor markers for CyberKnife stereotactic radiation therapy

    International Nuclear Information System (INIS)

    Karaman, Kutlay; Dokdok, A. Murat; Karadeniz, Okatay; Ceylan, Cemile; Engin, Kayihan

    2015-01-01

    To present our experience with placing endovascular coils in pulmonary arteries used as a fiducial marker for CyberKnife therapy and to describe the technical details and complications of the procedure. Between June 2005 and September 2013, 163 patients with primary or secondary lung malignancies, referred for fiducial placement for stereotactic radiosurgery, were retrospectively reviewed. Fourteen patients (9 men, 5 women; mean age, 70 years) with a history of pneumonectomy (n = 3), lobectomy (n = 3) or with severe cardiopulmonary co-morbidity (n = 8) underwent coil (fiducial marker) placement. Pushable or detachable platinum micro coils (n = 49) 2-3 mm in size were inserted through coaxial microcatheters into a small distal pulmonary artery in the vicinity of the tumor under biplane angiography/fluoroscopy guidance. Forty nine coils with a median number of 3 coils per tumor were placed with a mean tumor-coil distance of 2.7 cm. Forty three (87.7%) of 49 coils were successfully used as fiducial markers. Two coils could not be used due to a larger tumor-coil distance (> 50 mm). Four coils were in an acceptable position but their non-coiling shape precluded tumor tracking for CyberKnife treatment. No major complications needing further medication other than nominal therapy, hospitalization more than one night or permanent adverse sequale were observed. Endovascular placement of coil as a fiducial marker is safe and feasible during CyberKnife therapy, and might be an option for the patients in which percutaneous transthoracic fiducial placement might be risky.

  12. Negative ion detachment cross sections

    International Nuclear Information System (INIS)

    Champion, R.L.; Doverspike, L.D.

    1992-10-01

    The authors have measured absolute cross sections for electron detachment and charge exchange for collision of O and S with atomic hydrogen, have investigated the sputtering and photodesorption of negative ions from gas covered surfaces, and have begun an investigation of photon-induced field emission of electrons from exotic structures. Brief descriptions of these activities as well as future plans for these projects are given below

  13. Variations of posterior vitreous detachment

    OpenAIRE

    Kakehashi, A.; Kado, M.; Akiba, J.; Hirokawa, H.

    1997-01-01

    AIMS—To identify variations in posterior vitreous detachment (PVD) and establish a clinical classification system for PVD.
METHODS—400 consecutive eyes were examined using biomicroscopy and vitreous photography and classified the PVD variations—complete PVD with collapse, complete PVD without collapse, partial PVD with thickened posterior vitreous cortex (TPVC), or partial PVD without TPVC.
RESULTS—In each PVD type, the most frequently seen ocular pathologies were as follows: in complete PVD ...

  14. Classification of posterior vitreous detachment

    OpenAIRE

    Kakehashi, Akihiro; Takezawa, Mikiko; Akiba, Jun

    2013-01-01

    Akihiro Kakehashi,1 Mikiko Takezawa,1 Jun Akiba21Department of Ophthalmology, Jichi Medical University, Saitama Medical Center, Saitama, 2Kanjodori Eye Clinic, Asahikawa, JapanAbstract: Diagnosing a posterior vitreous detachment (PVD) is important for predicting the prognosis and determining the indication for vitreoretinal surgery in many vitreoretinal diseases. This article presents both classifications of a PVD by slit-lamp biomicroscopy and of a shallow PVD by optical coherence tomography...

  15. Coiled-coil networking shapes cell molecular machinery

    Science.gov (United States)

    Wang, Yongqiang; Zhang, Xinlei; Zhang, Hong; Lu, Yi; Huang, Haolong; Dong, Xiaoxi; Chen, Jinan; Dong, Jiuhong; Yang, Xiao; Hang, Haiying; Jiang, Taijiao

    2012-01-01

    The highly abundant α-helical coiled-coil motif not only mediates crucial protein–protein interactions in the cell but is also an attractive scaffold in synthetic biology and material science and a potential target for disease intervention. Therefore a systematic understanding of the coiled-coil interactions (CCIs) at the organismal level would help unravel the full spectrum of the biological function of this interaction motif and facilitate its application in therapeutics. We report the first identified genome-wide CCI network in Saccharomyces cerevisiae, which consists of 3495 pair-wise interactions among 598 predicted coiled-coil regions. Computational analysis revealed that the CCI network is specifically and functionally organized and extensively involved in the organization of cell machinery. We further show that CCIs play a critical role in the assembly of the kinetochore, and disruption of the CCI network leads to defects in kinetochore assembly and cell division. The CCI network identified in this study is a valuable resource for systematic characterization of coiled coils in the shaping and regulation of a host of cellular machineries and provides a basis for the utilization of coiled coils as domain-based probes for network perturbation and pharmacological applications. PMID:22875988

  16. Heterodimeric coiled-coil interactions of human GABAB receptor.

    Science.gov (United States)

    Burmakina, Svetlana; Geng, Yong; Chen, Yan; Fan, Qing R

    2014-05-13

    Metabotropic GABAB receptor is a G protein-coupled receptor that mediates inhibitory neurotransmission in the CNS. It functions as an obligatory heterodimer of GABAB receptor 1 (GBR1) and GABAB receptor 2 (GBR2) subunits. The association between GBR1 and GBR2 masks an endoplasmic reticulum (ER) retention signal in the cytoplasmic region of GBR1 and facilitates cell surface expression of both subunits. Here, we present, to our knowledge, the first crystal structure of an intracellular coiled-coil heterodimer of human GABAB receptor. We found that polar interactions buried within the hydrophobic core determine the specificity of heterodimer pairing. Disruption of the hydrophobic coiled-coil interface with single mutations in either subunit impairs surface expression of GBR1, confirming that the coiled-coil interaction is required to inactivate the adjacent ER retention signal of GBR1. The coiled-coil assembly buries an internalization motif of GBR1 at the heterodimer interface. The ER retention signal of GBR1 is not part of the core coiled-coil structure, suggesting that it is sterically shielded by GBR2 upon heterodimer formation.

  17. Electrospun Buckling Coils

    Science.gov (United States)

    Xin, Yu; Reneker, Darrell

    2009-03-01

    Electrospinning offers a useful way to produce fibers with micron and nanometer scale diameter. The present work deals with the buckling phenomenon characteristic of a jet impinging upon the surface of collector. A viscous jet may have either tensile or compressive forces along its axis. The periodic buckling that is often observed is attributed to the occurrence of compressive forces as the jet decelerates at the collector. With the increase of axial compressive stresses along the jet, a jet with circular cross sections first buckles by formation of sharp folds, and then by formation of coils. The resulting buckling patterns include zigzag patterns and coils that which can be controlled by changing parameters, such as density, viscosity, conductivity, voltage, polymer concentration, distance and volumetric flow rate. Uniformly buckled polymer fibers can be made at a rate of one turn per microsecond. An experimental apparatus was built to continuously collect buckling coils of nylon 6, from a water surface, into a multilayer sheet. These small ``springs'' and sheets will be tested for mechanical properties needed in biomedical applications.

  18. Posterior vitreous detachment and retinal detachment after cataract surgery.

    Science.gov (United States)

    Ripandelli, Guido; Coppé, Andrea Maria; Parisi, Vincenzo; Olzi, Diego; Scassa, Cecilia; Chiaravalloti, Adele; Stirpe, Mario

    2007-04-01

    To evaluate possible changes of vitreous status in emmetropic eyes after uneventful phacoemulsification surgery, and possible related complications such as the onset of retinal detachment (RD). Retrospective case series. Four hundred fifty-three emmetropic eyes from 453 patients (mean age, 62.03+/-5.57 years) subjected to uneventful phacoemulsification with intraocular lens implantation in the capsular bag were considered in the study. They had a refractive error within +/-0.5 diopters (mean, -0.21+/-0.08). Eyes with peripheral retinal lattice degeneration were included only if asymptomatic and only if the degeneration involved one retinal quadrant. After cataract surgery, the 453 eyes were evaluated preoperatively at days 1, 15, and 30 and months 3, 6, 12, 18, 24, 36, 48, and 60. The whole period of follow-up was 5 years. Evaluation of vitreous status by biomicroscopic examination, indirect binocular ophthalmoscopy, and B-scan ultrasonography. Postoperative onset of posterior vitreous detachment (PVD) and RD. After cataract surgery, a PVD occurred in 107 of 141 (75.88%) eyes without preoperative PVD or lattice degeneration. Posterior vitreous detachment occurred in 41 of 47 eyes (87.23%) with preoperative lattice degeneration and no PVD. Eyes with preoperative lattice degeneration and postoperative PVD showed a higher incidence of RD after cataract surgery (21.27%) than eyes without preoperative PVD or lattice degeneration (0.70%). In all patients with lattice degeneration, RD originated from horseshoe retinal tears on lattice areas located on the superior quadrants. No correlation was observed between the development of RD and age. Our results suggest that the onset of postoperative PVD should be considered an important risk factor for the development of RD after cataract surgery, particularly in eyes with lattice areas.

  19. Classification of posterior vitreous detachment

    Science.gov (United States)

    Kakehashi, Akihiro; Takezawa, Mikiko; Akiba, Jun

    2014-01-01

    Diagnosing a posterior vitreous detachment (PVD) is important for predicting the prognosis and determining the indication for vitreoretinal surgery in many vitreoretinal diseases. This article presents both classifications of a PVD by slit-lamp biomicroscopy and of a shallow PVD by optical coherence tomography (OCT). By biomicroscopy, the vitreous condition is determined based on the presence or absence of a PVD. The PVD then is classified as either a complete posterior vitreous detachment (C-PVD) or a partial posterior vitreous detachment (P-PVD). A C-PVD is further divided into a C-PVD with collapse and a C-PVD without collapse, while a P-PVD is divided into a P-PVD with shrinkage of the posterior hyaloid membrane (P-PVD with shrinkage) and a P-PVD without shrinkage of the posterior hyaloid membrane (P-PVD without shrinkage). A P-PVD without shrinkage has a subtype characterized by vitreous gel attachment through the premacular hole in a posterior hyaloid membrane to the macula (P-PVD without shrinkage [M]). By OCT, a shallow PVD is classified as the absence of a shallow PVD or as a shallow PVD. A shallow PVD is then subclassified as a shallow PVD without shrinkage of the posterior vitreous cortex, a shallow PVD with shrinkage of the posterior vitreous cortex, and a peripheral shallow PVD. A shallow PVD without shrinkage of the posterior vitreous cortex has two subtypes: an age-related shallow PVD and a perifoveal PVD associated with a macular hole. PMID:24376338

  20. Large coil test structural analysis

    International Nuclear Information System (INIS)

    Clinard, J.A.; Hammonds, C.J.

    1986-01-01

    The International Fusion Superconducting Magnet Test Facility (IFSMTF) at Oak Ridge National Laboratory (ORNL) is being utilized for testing of 2.5 x 3.5-m bore superconducting 8-T magnets produced by four international agencies (U.S., Euratom, Japan, and Switzerland). The definitive tests in the design configuration, six coils arranged in a compact torus, will begin in late 1985. Partial-array tests involving one US coil and the Japanese coil were completed in the fall of 1984. This presentation describes structural analysis using NASTRAN, with symmetry and superelement techniques, to predict the IFSMTF test stand and coil responses to various combinations of in-plane and out-of-plane loading conditions for both the partial-array and six-coil test configurations. Comparison to partial-array displacement and strain measurements are presented and discussed. Six-coil results and their utilization for determining safe levels of operation of the system are likewise discussed

  1. Fluorine negative ion detachment kinetics

    Science.gov (United States)

    Burke, R. R.; Miller, W. J.; Gould, R. K.

    1971-01-01

    A study of the rate of F(-) detachment by O and H atoms via the reactions F(-) + O yields FO + e and F(-) + H yields FH+ e was undertaken using a drift tube to produce F(-) ions at various drift velocities and therefore different ion temperatures. Preliminary mobility measurements of F(-) ions in Ar were made, indicating that ion temperatures in the 300 K to 5000 K range could be achieved; however due to numerous difficulties experienced in obtaining a reliable F(-) ion source, the study could not be completed.

  2. Outcomes in bullous retinal detachment

    Directory of Open Access Journals (Sweden)

    Sarah P. Read

    2017-06-01

    Conclusions and importance: GRTs are an uncommon cause of retinal detachment. While pars plana vitrectomy with tamponade is standard in GRT management, there is variability in the use of scleral buckling and PFO in these cases. This is in contrast to retinal dialysis where scleral buckle alone can yield favorable results. Though a baseball ocular trauma is common, retinal involvement is rare compared to other sports injuries such as those occurring with tennis, soccer and golf. Sports trauma remains an important cause of retinal injury and patients should be counseled on the need for eye protection.

  3. Coil Optimization for HTS Machines

    DEFF Research Database (Denmark)

    Mijatovic, Nenad; Jensen, Bogi Bech; Abrahamsen, Asger Bech

    An optimization approach of HTS coils in HTS synchronous machines (SM) is presented. The optimization is aimed at high power SM suitable for direct driven wind turbines applications. The optimization process was applied to a general radial flux machine with a peak air gap flux density of ~3T...... is suitable for which coil segment is presented. Thus, the performed study gives valuable input for the coil design of HTS machines ensuring optimal usage of HTS tapes....

  4. Risk factor profile in retinal detachment

    Directory of Open Access Journals (Sweden)

    Azad Raj

    1988-01-01

    Full Text Available 150 cases of retinal detachment comprising 50 patients each of bilateral retinal detachment, unilateral retinal detachment without any retinal lesions in the fellow eve and unilateral retinal detachment with retinal lesions in the fellow eye were studied and the various associated risk factors were statistically analysed. The findings are discussed in relation to their aetiological and prognostic significance in the different types of retinal detachment. Based on these observations certain guidelines are offered which may be of value in decision making, in prophylactic detachment surgery. Tractional breaks in the superior temporal quadrant especially when symptomatic. mandate prophylactic treatment. Urgency is enhanced it′ the patient is aphakic. Associated myopia adds to the urgency. The higher incidence of initial right e′ e involvement in all groups suggests a vascular original possibly ischaemic.

  5. Large superconducting coil fabrication development

    International Nuclear Information System (INIS)

    Brown, R.L.; Allred, E.L.; Anderson, W.C.; Burn, P.B.; Deaderick, R.I.; Henderson, G.M.; Marguerat, E.F.

    1975-01-01

    Toroidal fields for some fusion devices will be produced by an array of large superconducting coils. Their size, space limitation, and field requirements dictate that they be high performance coils. Once installed, accessibility for maintenance and repairs is severely restricted; therefore, good reliability is an obvious necessity. Sufficient coil fabrication will be undertaken to develop and test methods that are reliable, fast, and economical. Industrial participation will be encouraged from the outset to insure smooth transition from development phases to production phases. Initially, practice equipment for three meter bore circular coils will be developed. Oval shape coil forms will be included in the practice facility later. Equipment that is more automated will be developed with the expectation of winding faster and obtaining good coil quality. Alternate types of coil construction, methods of winding and insulating, will be investigated. Handling and assembly problems will be studied. All technology developed must be feasible for scaling up when much larger coils are needed. Experimental power reactors may need coils having six meter or larger bores

  6. Simple Coiling versus Stent-Assisted Coiling of Paraclinoid Aneurysms: Radiological Outcome in a Single Center Study.

    Science.gov (United States)

    Kim, Soo Yeon; Park, Dong Sun; Park, Hye Yin; Chun, Young Il; Moon, Chang Taek; Roh, Hong Gee

    2017-11-01

    Paraclinoid aneurysms are a group of aneurysms arising at the distal internal carotid artery. Due to a high incidence of small, wide-necked aneurysms in this zone, it is often challenging to achieve complete occlusion when solely using detachable coils, thus stent placement is often required. In the present study, we aimed to investigate the effect of stent placement in endovascular treatment of paraclinoid aneurysms. Data of 98 paraclinoid aneurysms treated by endovascular approach in our center from August 2005 to June 2016 were retrospectively reviewed. They were divided into two groups: simple coiling and stent-assisted coiling. Differences in the recurrence and progressive occlusion between the two groups were mainly analyzed. The recurrence was defined as more than one grade worsening according to Raymond-Roy Classification or major recanalization that is large enough to permit retreatment in the follow-up study compared to the immediate post-operative results. Complete occlusion was achieved immediately after endovascular treatment in eight out of 37 patients (21.6%) in the stent-assisted group and 18 out of 61 (29.5%) in the simple coiling group. In the follow-up imaging studies, the recurrence rate was lower in the stent-assisted group (one out of 37, 2.7%) compared to the simple coiling group (13 out of 61, 21.3%) ( p =0.011). Multivariate logistic regression model showed lower recurrence rate in the stent-assisted group than the simple coiling group (odds ratio [OR] 0.051, 95% confidence interval [CI] 0.005-0.527). Furthermore there was also a significant difference in the rate of progressive occlusion between the stent-assisted group (16 out of 29 patients, 55.2%) and the simple coiling group (10 out of 43 patients, 23.3%) ( p =0.006). The stent-assisted group also exhibited a higher rate of progressive occlusion than the simple coiling group in the multivariate logistic regression model (OR 3.208, 95% CI 1.106-9.302). Use of stents results in good

  7. Triple Halo Coil: Development and Comparison with Other TMS Coils

    Science.gov (United States)

    Rastogi, Priyam; Hadimani, Ravi; Jiles, David

    Transcranial Magnetic Stimulation (TMS) is a non-invasive stimulation technique that can be used for the treatment of various neurological disorders such as Parkinson's Disease, PTSD, TBI and anxiety by regulating synaptic activity. TMS is FDA approved for the treatment of major depressive disorder. There is a critical need to develop deep TMS coils that can stimulate deeper regions of the brain without excessively stimulating the cortex in order to provide an alternative to surgical methods. We have developed a novel multi-coil configuration called ``Triple Halo Coil'' (THC) that can stimulate deep brain regions. Investigation of induced electric and magnetic field in these regions have been achieved by computer modelling. Comparison of the results due to THC configuration have been conducted with other TMS coils such as ``Halo Coil'', circular coil and ``Figure of Eight'' coil. There was an improvement of more than 15 times in the strength of magnetic field, induced by THC configuration at 10 cm below the vertex of the head when compared with the ``Figure of Eight'' coil alone. Carver Charitable Trust.

  8. High-resolution structures of a heterochiral coiled coil.

    Science.gov (United States)

    Mortenson, David E; Steinkruger, Jay D; Kreitler, Dale F; Perroni, Dominic V; Sorenson, Gregory P; Huang, Lijun; Mittal, Ritesh; Yun, Hyun Gi; Travis, Benjamin R; Mahanthappa, Mahesh K; Forest, Katrina T; Gellman, Samuel H

    2015-10-27

    Interactions between polypeptide chains containing amino acid residues with opposite absolute configurations have long been a source of interest and speculation, but there is very little structural information for such heterochiral associations. The need to address this lacuna has grown in recent years because of increasing interest in the use of peptides generated from d amino acids (d peptides) as specific ligands for natural proteins, e.g., to inhibit deleterious protein-protein interactions. Coiled-coil interactions, between or among α-helices, represent the most common tertiary and quaternary packing motif in proteins. Heterochiral coiled-coil interactions were predicted over 50 years ago by Crick, and limited experimental data obtained in solution suggest that such interactions can indeed occur. To address the dearth of atomic-level structural characterization of heterochiral helix pairings, we report two independent crystal structures that elucidate coiled-coil packing between l- and d-peptide helices. Both structures resulted from racemic crystallization of a peptide corresponding to the transmembrane segment of the influenza M2 protein. Networks of canonical knobs-into-holes side-chain packing interactions are observed at each helical interface. However, the underlying patterns for these heterochiral coiled coils seem to deviate from the heptad sequence repeat that is characteristic of most homochiral analogs, with an apparent preference for a hendecad repeat pattern.

  9. Coiled Coils Ensure the Physiological Ectodomain Shedding of Collagen XVII*

    Science.gov (United States)

    Nishie, Wataru; Jackow, Joanna; Hofmann, Silke C.; Franzke, Claus-Werner; Bruckner-Tuderman, Leena

    2012-01-01

    α-Helical coiled coils, frequent protein oligomerization motifs, are commonly observed in vital proteins. Here, using collagen XVII as an example, we provide evidence for a novel function of coiled coils in the regulation of ectodomain shedding. Transmembrane collagen XVII, an epithelial cell surface receptor, mediates dermal-epidermal adhesion in the skin, and its dysfunction is linked to human skin blistering diseases. The ectodomain of this collagen is constitutively shed from the cell surface by proteinases of a disintegrin and metalloprotease family; however, the mechanisms regulating shedding remain elusive. Here, we used site-specific mutagenesis to target the coiled-coil heptad repeats within the juxtamembranous, extracellular noncollagenous 16th A (NC16A) domain of collagen XVII. This resulted in a substantial increase of ectodomain shedding, which was not mediated by disintegrin and metalloproteases. Instead, conformational changes induced by the mutation(s) unmasked a furin recognition sequence that was used for cleavage. This study shows that apart from their functions in protein oligomerization, coiled coils can also act as regulators of ectodomain shedding depending on the biological context. PMID:22761443

  10. The coiled coil motif in polymer drug delivery systems

    Czech Academy of Sciences Publication Activity Database

    Pechar, Michal; Pola, Robert

    2013-01-01

    Roč. 31, č. 1 (2013), s. 90-96 ISSN 0734-9750 R&D Projects: GA ČR GA203/08/0543; GA MŠk 1M0505 Institutional research plan: CEZ:AV0Z40500505 Keywords : coiled coil * hydrophilic polymer * recombinant protein Subject RIV: CD - Macromolecular Chemistry Impact factor: 8.905, year: 2013

  11. Competition between Coiled-Coil Structures and the Impact on Myosin-10 Bundle Selection.

    Science.gov (United States)

    Vavra, Kevin C; Xia, Youlin; Rock, Ronald S

    2016-06-07

    Coiled-coil fusions are a useful approach to enforce dimerization in protein engineering. However, the final structures of coiled-coil fusion proteins have received relatively little attention. Here, we determine the structural outcome of adjacent parallel and antiparallel coiled coils. The targets are coiled coils that stabilize myosin-10 in single-molecule biophysical studies. We reveal the solution structure of a short, antiparallel, myosin-10 coiled-coil fused to the parallel GCN4-p1 coiled coil. Surprisingly, this structure is a continuous, antiparallel coiled coil where GCN4-p1 pairs with myosin-10 rather than itself. We also show that longer myosin-10 segments in these parallel/antiparallel fusions are dynamic and do not fold cooperatively. Our data resolve conflicting results on myosin-10 selection of actin filament bundles, demonstrating the importance of understanding coiled-coil orientation and stability. Copyright © 2016 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  12. Rhematogenous retinal detachment complicated by severe intraocular inflammation, hypotony, and choroidal detachment.

    OpenAIRE

    Jarrett, W H

    1981-01-01

    An unusual type of rhegmatogenous retinal detachment is described and compared with a control group of patients with detached retina. Features of the condition, in addition to retinal detachment, include severe anterior and posterior uveitis, choroidal detachment, hypotony, deepened anterior chamber, posterior synechiae, iridophakodonesis, and a poor surgical and visual prognosis due to massive periretinal proliferation. The disease occurs in a disproportionately high ratio in blacks. These c...

  13. CCHMM_PROF: a HMM-based coiled-coil predictor with evolutionary information

    DEFF Research Database (Denmark)

    Bartoli, Lisa; Fariselli, Piero; Krogh, Anders

    2009-01-01

    MOTIVATION: The widespread coiled-coil structural motif in proteins is known to mediate a variety of biological interactions. Recognizing a coiled-coil containing sequence and locating its coiled-coil domains are key steps towards the determination of the protein structure and function. Different...

  14. "Slinky" coils for neuromagnetic stimulation.

    Science.gov (United States)

    Zimmermann, K P; Simpson, R K

    1996-04-01

    Future advances in neuromagnetic stimulation depend significantly on the design of coils with improved focality. Although in the absence of internal current sources, no true focusing of magnetically induced currents is possible, improvements in the focality of current concentrations passing through an area of biologic tissue are achievable through variations of the shape, orientation and size of neuromagnetic stimulating coils. The "butterfly" and the "4-leaf" coils are two examples of planar designs which achieve improved focality through centralization of the maximum coil current and peripheral distribution of the return currents. We introduce the "slinky" coil design as a 3-dimensional generalization of the principle of peripheral distribution of return currents and demonstrate its advantages over planar designs.

  15. Detached divertor plasmas in JET

    Energy Technology Data Exchange (ETDEWEB)

    Horton, L.D.; Borrass, K.; Corrigan, G.; Gottardi, N.; Lingertat, J.; Loarte, A.; Simonini, R.; Stamp, M.F.; Taroni, A. [Commission of the European Communities, Abingdon (United Kingdom). JET Joint Undertaking; Stangeby, P.C. [Toronto Univ., ON (Canada). Inst. for Aerospace Studies

    1994-07-01

    In simulations with high radiated power fractions, it is possible to produce the drop in ion current to the divertor targets typical of detached plasmas. Despite the fact that these experiments are performed on beryllium target tiles, radiation from deuterium and beryllium cannot account for the measured power losses. The neutral deuterium levels in the SOL in these plasmas are higher than the model predicts. This may be due to leakage from the divertor or to additional wall sources related to the non-steady nature of these plasmas. In contrast, a surprisingly high level of carbon is present in these discharges; higher even than would be predicted are the divertor target tiles pure carbon. This level may well be large enough to produce the measured radiation. (authors). 6 refs., 2 figs., 1 tab.

  16. Thermal analysis of COIL

    Science.gov (United States)

    Takeuchi, Noriyuki; Sugimoto, Daichi; Tei, Kazuyoku; Fujioka, Tomoo

    2004-05-01

    Analysis of heat release into operative gas of Chemical Oxygen Iodine Laser (COIL) is discussed. Pooling reaction of oxygen molecules in the excited state, the iodine dissociation process and the interaction of them with water vapor release energy of in the excited state oxygen molecules as heat energy. As results of heat release in the plenum, a rise of the total pressure as a rise of the total temperature is observed, and in the supersonic region a rise of static pressure and a decrease of total pressure as a rise of total temperature are observed. By following our analysis technique regarding pressure data of three different nozzles, the evaluations such as energy loss in a duct from a Singlet delta Oxygen Generator (SOG) and the number of dissipated oxygen molecules for the iodine dissociation can be estimated.

  17. Rhegmatogenous retinal detachment and uveitis.

    Science.gov (United States)

    Kerkhoff, Frank T; Lamberts, Querin J; van den Biesen, Pieter R; Rothova, Aniki

    2003-02-01

    To evaluate the frequency, high-risk factors, and visual prognosis of rhegmatogenous retinal detachment (RRD) in patients with uveitis. Retrospective case-control study. We included 1387 consecutive patients with uveitis who consulted our uveitis clinic from January 1990 through December 1997 of whom 43 patients (46 eyes) with RRD were identified. The retinal detachment (RD) controls were 212 consecutive patients with RRD (221 eyes, first occurrence of RD, not associated with uveitis) who were admitted for surgery in the period from April 1999 to April 2000. The uveitis control group consisted of 150 age-matched patients (210 eyes) selected from the entire uveitis series. Retrospective analysis of clinical data. The presence of RRD and eventual risk factors for RRD, such as myopia, retinal lattice degeneration, prior intraocular surgery, anatomic location of uveitis, its specific diagnosis, and clinical manifestations. Furthermore, the surgical and nonsurgical outcomes of RRD, as well as the results of various treatment regimens, were analyzed. RRD was identified in 3.1% of the patients with uveitis. RRD was most frequently associated with panuveitis (6.6%). RRD was associated more frequently with infectious (7.6%) than noninfectious uveitis (2.1%). At the onset of RRD, uveitis was active in most (46%) affected eyes. Proliferative vitreoretinopathy was present in 30% of the uveitic RRD eyes at presentation in contrast to 12% of the RRD control eyes. In uveitic RRD, the retina was reattached in 59% of eyes with a single operation; the final anatomic reattachment rate was 88%. Finally, a visual acuity of less than 20/200 was present in 71% of the uveitic RRD eyes, 10% of which had no light perception. We discovered a high prevalence of RRD in patients with active panuveitis and infectious uveitis and document that uveitis in itself is a risk factor for the development of RRD. The visual prognosis of RRD in uveitis was poor because of the uveitis itself and the

  18. Superconducting cyclotron magnet coil short

    International Nuclear Information System (INIS)

    Mallory, M.L.; Blosser, H.G.; Clark, D.J.; Launer, H.; Lawton, D.; Miller, P.; Resmini, F.

    1982-01-01

    In February 1981, a short circuit appeared in the superconducting coil of the K500 cyclotron. The short is resistive in character and therefore has no effect on steady state operation of the magnet. The resistance of the short varies, sometimes being below threshold of detection as a heat load on the cooling system and sometimes being significant. The resistance under certain conditions shows approximately cyclic phenomena with time constants in the range of seconds and other approximately cyclic phenomena which correlate with gross operating parameters of the magnet (shifting current from one coil to another at high field and lowering and raising the liquid helium level). A number of diagnostic studies of the short have been made, using 1) an array of flux sensing loops to sense the magnetic effect of the short, 2) voltage comparisons between upper and lower sections of the coil, 3) comparisons of forces in the nine member coil support system and 4) the effect of the short on the thermal charactersitics of the coil. Insulation failure or a metal chip shorting out turns have been explored in some detail but a convincing determination of the exact cause of the short may never be available, (even the extreme step of unwinding the coil having a significant probability that an imperfection with the observed characteristics would pass unnoticed). Analysis of the characteristics of the short indicated that the most serious consequence would be failure of the coils mechanical support system in the event that the magnet was quickly discharged, as in a dump or quench. To deal with this hazard, the support system has been modified by installing solid supports which prevent the coil from moving by an amount sufficient to damage the support system. We have also reexamined the data and calculations used in the original coil design and have made some additional measurements of the properties of the materials (yield strength, friction coefficient, Young's modulus) used in the

  19. The IEA Large Coil Task

    International Nuclear Information System (INIS)

    Beard, D.S.; Klose, W.; Shimamoto, S.; Vecsey, G.

    1988-01-01

    A multinational program of cooperative research, development, demonstrations, and exchanges of information on superconducting magnets for fusion was initiated in 1977 under an IEA agreement. The first major step in the development of TF magnets was called the Large Coil Task. Participants in LCT were the U.S. DOE, EURATOM, JAERI, and the Departement Federal de l'Interieur of Switzerland. The goals of LCT were to obtain experimental data, to demonstrate reliable operation of large superconducting coils, and to prove design principles and fabrication techniques being considered for the toroidal magnets of thermonuclear reactors. These goals were to be accomplished through coordinated but largely independent design, development, and construction of six test coils, followed by collaborative testing in a compact toroidal test array at fields of 8 T and higher. Under the terms of the IEA Agreement, the United States built and operated the test facility at Oak Ridge and provided three test coils. The other participants provided one coil each. Information on design and manufacturing and all test data were shared by all. The LCT team of each participant included a government laboratory and industrial partners or contractors. The last coil was completed in 1985, and the test assembly was completed in October of that year. Over the next 23 months, the six-coil array was cooled down and extensive testing was performed. Results were gratifying, as tests achieved design-point performance and well beyond. (Each coil reached a peak field of 9 T.) Experiments elucidated coil behavior, delineated limits of operability, and demonstrated coil safety. (orig./KP)

  20. Experimental results from detached plasmas in TFTR

    International Nuclear Information System (INIS)

    Strachan, J.D.; Boody, F.P.; Bush, C.E.

    1986-10-01

    Detached plasmas are formed in TFTR which have the principal property of the boundary to the high temperature plasma core being defined by a radiating layer. This paper documents the properties of TFTR ohmic-detached plasmas with a range of plasma densities at two different plasma currents

  1. Retinal detachment in black South Africans

    African Journals Online (AJOL)

    Rhegmatogenous retinal detachments seen in black patients attending King Edward VIII Hospital. Ophthalmology Clinic over a 5-year period from January. 1987 to December 1991 were reviewed. Penetrating trauma and diabetic retinopathy were excluded. There were 114 detachments in 112 patients, which gave.

  2. Superconducting poloidal coils for STARFIRE commercial reactor

    International Nuclear Information System (INIS)

    Wang, S.T.; Evans, K. Jr.; Turner, L.R.; Huang, Y.C.; Prater, R.; Alcorn, J.

    1979-01-01

    STARFIRE is considered to be the tenth commercial tokamak power plant. A preliminary design study on its superconducting poloidal coil system is presented. Key features of the design studies are: the elimination of the ohmic heating coil; the trade-off studies of the equilibrium field coil locations; and the development of a conceptual design for the superconducting equilibrium field coils. Described are the 100 kA cryostable conductor design, the coil structure, and evaluation of the coil forces

  3. Intraretinal proliferation induced by retinal detachment

    Energy Technology Data Exchange (ETDEWEB)

    Fisher, S.K.; Erickson, P.A.; Lewis, G.P.; Anderson, D.H. (Univ. of California, Santa Barbara (USA))

    1991-05-01

    Cellular proliferation after retinal detachment was studied by {sup 3}H-thymidine light microscopic autoradiography in cats that had experimental detachments of 0.5-180 days duration. The animals underwent labeling 2 hr before death with an intraocular injection of 200 microCi of {sup 3}H-thymidine. The number of labeled nuclei were counted in 1-micron thick tissue sections in regions of detachment, in regions of the experimental eyes that remained attached, and in control eyes that had no detachments. In the normal eye, in one that had only the lens and vitreous removed, and in the eyes with 0.5- and 1-day detachments, the number of labeled nuclei ranged from 0/mm (0.5-day detachment) to 0.38/mm (lens and vitreous removed only). By 2 days postdetachment, the number of labeled nuclei increased to 2.09/mm. The highest levels of labeling occurred in two animals with detachments of 3 (7.86/mm) and 4 (7.09/mm) days. Thereafter, the numbers declined steadily until near-baseline counts were obtained at 14 days. The number of labeled nuclei was slightly elevated in the attached regions of two animals with 3-day detachments. Labeled cell types included: Mueller cells, astrocytes, pericytes, and endothelial cells of the retinal vasculature, and both resident (microglial cells) and invading macrophages. In an earlier study RPE cells were also shown to proliferate in response to detachment. Thus, these data show that proliferation is a rapid response to detachment, reaching a maximum within 4 days, and that virtually every nonneuronal cell type in the retina can participate in this response. The data suggest that events leading to such clinical manifestations as proliferative vitreoretinopathy and subretinal fibrosis may have their beginnings in this very early proliferative response.

  4. Intraretinal proliferation induced by retinal detachment

    International Nuclear Information System (INIS)

    Fisher, S.K.; Erickson, P.A.; Lewis, G.P.; Anderson, D.H.

    1991-01-01

    Cellular proliferation after retinal detachment was studied by 3 H-thymidine light microscopic autoradiography in cats that had experimental detachments of 0.5-180 days duration. The animals underwent labeling 2 hr before death with an intraocular injection of 200 microCi of 3 H-thymidine. The number of labeled nuclei were counted in 1-micron thick tissue sections in regions of detachment, in regions of the experimental eyes that remained attached, and in control eyes that had no detachments. In the normal eye, in one that had only the lens and vitreous removed, and in the eyes with 0.5- and 1-day detachments, the number of labeled nuclei ranged from 0/mm (0.5-day detachment) to 0.38/mm (lens and vitreous removed only). By 2 days postdetachment, the number of labeled nuclei increased to 2.09/mm. The highest levels of labeling occurred in two animals with detachments of 3 (7.86/mm) and 4 (7.09/mm) days. Thereafter, the numbers declined steadily until near-baseline counts were obtained at 14 days. The number of labeled nuclei was slightly elevated in the attached regions of two animals with 3-day detachments. Labeled cell types included: Mueller cells, astrocytes, pericytes, and endothelial cells of the retinal vasculature, and both resident (microglial cells) and invading macrophages. In an earlier study RPE cells were also shown to proliferate in response to detachment. Thus, these data show that proliferation is a rapid response to detachment, reaching a maximum within 4 days, and that virtually every nonneuronal cell type in the retina can participate in this response. The data suggest that events leading to such clinical manifestations as proliferative vitreoretinopathy and subretinal fibrosis may have their beginnings in this very early proliferative response

  5. Coil protection calculator for TFTR

    International Nuclear Information System (INIS)

    Marsala, R.J.; Lawson, J.E.; Persing, R.G.; Senko, T.R.; Woolley, R.D.

    1989-01-01

    A new coil protection system (CPS) is being developed to replace the existing TFTR magnetic coil fault detector. The existing fault detector sacrifices TFTR operating capability for simplicity. The new CPS, when installed in October of 1988, will permit operation up to the actual coil stress limits parameters in real-time. The computation will be done in a microprocessor based Coil Protection Calculator (CPC) currently under construction at PPL. THe new CPC will allow TFTR to operate with higher plasma currents and will permit the optimization of pulse repetition rates. The CPC will provide real-time estimates of critical coil and bus temperatures and stresses based on real-time redundant measurements of coil currents, coil cooling water inlet temperature, and plasma current. The critical parameter calculations are compared to prespecified limits. If these limits are reached or exceeded, protection action will be initiated to a hard wired control system (HCS), which will shut down the power supplies. The CPC consists of a redundant VME based microprocessor system which will sample all input data and compute all stress quantities every ten milliseconds. Thermal calculations will be approximated every 10ms with an exact solution occurring every second. The CPC features continuous cross-checking of redundant input signal, automatic detection of internal failure modes, monitoring and recording of calculated results, and a quick, functional verification of performance via an internal test system. (author)

  6. Is umbilical coiling genetically determined?

    Science.gov (United States)

    Ayala, Nina K; Ernst, Linda M; Miller, Emily S

    2018-02-21

    Abnormal umbilical cord coiling is associated with adverse perinatal outcomes; however, the etiology of the umbilical coiling pattern is poorly understood. Retrospective cohort of all twin deliveries >20 weeks in 2014. Pregnancies were dichotomized by chorionicity and the umbilical coiling index (UCI) and placental cord insertion location were compared. In cases with one or both cords hypercoiled, the direction and pattern of coiling were compared by chorionicity. A similar analysis was performed stratified by zygosity. Three hundred sisty two twin pairs were included; 26 (7.2%) monochorionic and 174 (87.0%) definitively dizygotic. Concordance in the UCI and coiling category were similar between dichorionic and monochorionic as well as dizygous and monozygous gestations, (73.2% vs 80.8%, p = 0.399 and 71.4% vs 80.8%, p = 0.399, respectively). Analyses of the coiling direction and pattern also demonstrated no difference by chorionicity or zygosity. These data do not support a genetic basis for umbilical cord coiling.

  7. Coiled Coils - A Model System for the 21st Century.

    Science.gov (United States)

    Lupas, Andrei N; Bassler, Jens

    2017-02-01

    α-Helical coiled coils were described more than 60 years ago as simple, repetitive structures mediating oligomerization and mechanical stability. Over the past 20 years, however, they have emerged as one of the most diverse protein folds in nature, enabling many biological functions beyond mechanical rigidity, such as membrane fusion, signal transduction, and solute transport. Despite this great diversity, their structures can be described by parametric equations, making them uniquely suited for rational protein design. Far from having been exhausted as a source of structural insight and a basis for functional engineering, coiled coils are poised to become even more important for protein science in the coming decades. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Cross-linking reveals laminin coiled-coil architecture

    Science.gov (United States)

    Armony, Gad; Jacob, Etai; Moran, Toot; Levin, Yishai; Mehlman, Tevie; Levy, Yaakov; Fass, Deborah

    2016-01-01

    Laminin, an ∼800-kDa heterotrimeric protein, is a major functional component of the extracellular matrix, contributing to tissue development and maintenance. The unique architecture of laminin is not currently amenable to determination at high resolution, as its flexible and narrow segments complicate both crystallization and single-particle reconstruction by electron microscopy. Therefore, we used cross-linking and MS, evaluated using computational methods, to address key questions regarding laminin quaternary structure. This approach was particularly well suited to the ∼750-Å coiled coil that mediates trimer assembly, and our results support revision of the subunit order typically presented in laminin schematics. Furthermore, information on the subunit register in the coiled coil and cross-links to downstream domains provide insights into the self-assembly required for interaction with other extracellular matrix and cell surface proteins. PMID:27815530

  9. Design of Correction Coil for ITER

    International Nuclear Information System (INIS)

    Kubo, Hiroatsu; Yoshida, Kiyoshi; Omine, Takeshi

    1998-11-01

    ITER (International Thermonuclear Experimental Reactor) project is under way among EU, Japan, Russia and US. In order to shut plasma, the magnetic field is applied by the superconducting coils in ITER. The coils which are called 'Poloidal field (PF-coil)' are installed to control the location and the cross-section shape for plasma in the vacuum vessel. Incorrect position of Magnetic field (Magnetic error) is occurred by the manufacture tolerance for PF-coil. The coils which are called 'Correction-Coil' are installed in order to correct these magnetic error around the PF-coil. The Correction Coils are consist of the 3-sets of the superconducting coil. The stress analysis for the correction coils is performed and the supporting structure of the coils are designed. The bolts for clamps and the position for clamps are examined from this analysis. (J.P.N.)

  10. A new twist in the coil: functions of the coiled-coil domain of structural maintenance of chromosome (SMC) proteins.

    Science.gov (United States)

    Matityahu, Avi; Onn, Itay

    2018-02-01

    The higher-order organization of chromosomes ensures their stability and functionality. However, the molecular mechanism by which higher order structure is established is poorly understood. Dissecting the activity of the relevant proteins provides information essential for achieving a comprehensive understanding of chromosome structure. Proteins of the structural maintenance of chromosome (SMC) family of ATPases are the core of evolutionary conserved complexes. SMC complexes are involved in regulating genome dynamics and in maintaining genome stability. The structure of all SMC proteins resembles an elongated rod that contains a central coiled-coil domain, a common protein structural motif in which two α-helices twist together. In recent years, the imperative role of the coiled-coil domain to SMC protein activity and regulation has become evident. Here, we discuss recent advances in the function of the SMC coiled coils. We describe the structure of the coiled-coil domain of SMC proteins, modifications and interactions that are mediated by it. Furthermore, we assess the role of the coiled-coil domain in conformational switches of SMC proteins, and in determining the architecture of the SMC dimer. Finally, we review the interplay between mutations in the coiled-coil domain and human disorders. We suggest that distinctive properties of coiled coils of different SMC proteins contribute to their distinct functions. The discussion clarifies the mechanisms underlying the activity of SMC proteins, and advocates future studies to elucidate the function of the SMC coiled coil domain.

  11. Retinal detachment associated with traumatic chorioretinal rupture.

    Science.gov (United States)

    Papakostas, Thanos D; Yonekawa, Yoshihiro; Wu, David; Miller, John B; Veldman, Peter B; Chee, Yewlin E; Husain, Deeba; Eliott, Dean

    2014-01-01

    Traumatic chorioretinal rupture, also known as sclopetaria, is a full-thickness break of the choroid and retina caused by a high-velocity projectile striking or passing adjacent to, but not penetrating, the globe. Previous reports have emphasized that retinal detachment seldom occurs, and observation alone has been the recommended management strategy. However, the authors present herein a series of consecutive patients with retinal detachment associated with sclopetaria and provide a literature review of the topic. They recommend that patients with traumatic chorioretinal rupture be monitored closely for the development of retinal detachment during the first few weeks after the injury. Copyright 2014, SLACK Incorporated.

  12. First coil for the SC

    CERN Multimedia

    CERN PhotoLab

    1955-01-01

    The coils for the SC magnet were stored in the large hangar of the Cointrin Airport (to make sure that they would be available before snow and ice would block the roads and canals from Belgium, where they were built).

  13. Coil for LEAR extraction septum

    CERN Multimedia

    CERN PhotoLab

    1982-01-01

    Which way does the current flow ? This intriguing object is the coil for the LEAR extraction septum. There were two septa, first a thin one, then this one, not so thin, somewhat on the borderline between septum and bending magnet.

  14. Nylon screws make inexpensive coil forms

    Science.gov (United States)

    Aucoin, G.; Rosenthal, C.

    1978-01-01

    Standard nylon screws act as coil form copper wire laid down in spiral thread. Completed coil may be bonded to printed-circuit board. However, it is impossible to tune coil by adjusting spacing between windings, technique sometimes used with air-core coils.

  15. [Intraocular hypertension after retinal detachment surgery].

    Science.gov (United States)

    Muşat, O; Cristescu, R; Coman, Corina; Asandi, R

    2012-01-01

    This papers presents a case of a patient with retinal detachment, 3 days ago operated (posterior vitrectomy, internal tamponament with silicon oil 1000) who developed increased ocular pressure following silicon oil output in the anterior chamber.

  16. Rhegmatogenous retinal detachment following intravitreal ocriplasmin

    NARCIS (Netherlands)

    Madi, Haifa A.; Haynes, Richard J.; Depla, Diana; de la Cour, Morten D.; Lesnik-Oberstein, Sarit; Muqit, Mahi M. K.; Patton, Niall; Price, Nick; Steel, David H. W.

    2016-01-01

    To describe the characteristics and outcomes of patients presenting with rhegmatogenous retinal detachment (RRD) after ocriplasmin (OCP) injection. Retrospective, multi-centre, observational case series with case note review. Eight patients with symptomatic vitreomacular traction (six with

  17. Coil supporting device in nuclear fusion apparatus

    International Nuclear Information System (INIS)

    Hoshi, Ryo; Imura, Yasuya.

    1974-01-01

    Object: To secure intermediate fittings with a coil fixed thereon by an insulating tape to a fixed body by means of fittings, thereby supporting the coil in a narrow space. Structure: A coil is secured to intermediate fittings by means of an insulating tape, after which the intermediate fittings is mounted on a fixed body through fittings to support the coil in a narrow clearance portion between a plasma sealed vessel and a main coil. (Kamimura, M.)

  18. Single-molecule observation of helix staggering, sliding, and coiled coil misfolding

    Science.gov (United States)

    Xi, Zhiqun; Gao, Ying; Sirinakis, George; Guo, Honglian; Zhang, Yongli

    2012-01-01

    The biological functions of coiled coils generally depend on efficient folding and perfect pairing of their α-helices. Dynamic changes in the helical registry that lead to staggered helices have only been proposed for a few special systems and not found in generic coiled coils. Here, we report our observations of multiple staggered helical structures of two canonical coiled coils. The partially folded structures are formed predominantly by coiled coil misfolding and occasionally by helix sliding. Using high-resolution optical tweezers, we characterized their energies and transition kinetics at a single-molecule level. The staggered states occur less than 2% of the time and about 0.1% of the time at zero force. We conclude that dynamic changes in helical registry may be a general property of coiled coils. Our findings should have broad and unique implications in functions and dysfunctions of proteins containing coiled coils. PMID:22451899

  19. Designed Coiled Coils Promote Folding of a Recombinant Bacterial Collagen*

    Science.gov (United States)

    Yoshizumi, Ayumi; Fletcher, Jordan M.; Yu, Zhuoxin; Persikov, Anton V.; Bartlett, Gail J.; Boyle, Aimee L.; Vincent, Thomas L.; Woolfson, Derek N.; Brodsky, Barbara

    2011-01-01

    Collagen triple helices fold slowly and inefficiently, often requiring adjacent globular domains to assist this process. In the Streptococcus pyogenes collagen-like protein Scl2, a V domain predicted to be largely α-helical, occurs N-terminal to the collagen triple helix (CL). Here, we replace this natural trimerization domain with a de novo designed, hyperstable, parallel, three-stranded, α-helical coiled coil (CC), either at the N terminus (CC-CL) or the C terminus (CL-CC) of the collagen domain. CD spectra of the constructs are consistent with additivity of independently and fully folded CC and CL domains, and the proteins retain their distinctive thermal stabilities, CL at ∼37 °C and CC at >90 °C. Heating the hybrid proteins to 50 °C unfolds CL, leaving CC intact, and upon cooling, the rate of CL refolding is somewhat faster for CL-CC than for CC-CL. A construct with coiled coils on both ends, CC-CL-CC, retains the ∼37 °C thermal stability for CL but shows less triple helix at low temperature and less denaturation at 50 °C. Most strikingly however, in CC-CL-CC, the CL refolds slower than in either CC-CL or CL-CC by almost two orders of magnitude. We propose that a single CC promotes folding of the CL domain via nucleation and in-register growth from one end, whereas initiation and growth from both ends in CC-CL-CC results in mismatched registers that frustrate folding. Bioinformatics analysis of natural collagens lends support to this because, where present, there is generally only one coiled-coil domain close to the triple helix, and it is nearly always N-terminal to the collagen repeat. PMID:21454493

  20. Computational analysis of residue contributions to coiled-coil topology

    Science.gov (United States)

    Ramos, Jorge; Lazaridis, Themis

    2011-01-01

    A variety of features are thought to contribute to the oligomeric and topological specificity of coiled coils. In previous work, we examined the determinants of oligomeric state. Here, we examine the energetic basis for the tendency of six coiled-coil peptides to align their α-helices in antiparallel orientation using molecular dynamics simulations with implicit solvation (EEF1.1). We also examine the effect of mutations known to disrupt the topology of these peptides. In agreement with experiment, ARG or LYS at a or d positions were found to stabilize the antiparallel configuration. The modeling suggests that this is not due to a–a′ or d–d′ repulsions but due to interactions with e′ and g′ residues. TRP at core positions also favors the antiparallel configuration. Residues that disfavor parallel dimers, such as ILE at d, are better tolerated in, and thus favor the antiparallel configuration. Salt bridge networks were found to be more stabilizing in the antiparallel configuration for geometric reasons: antiparallel helices point amino acid side chains in opposite directions. However, the structure with the largest number of salt bridges was not always the most stable, due to desolvation and configurational entropy contributions. In tetramers, the extent of stabilization of the antiparallel topology by core residues is influenced by the e′ residue on a neighboring helix. Residues at b and c positions in some cases also contribute to stabilization of antiparallel tetramers. This work provides useful rules toward the goal of designing coiled coils with a well-defined and predictable three-dimensional structure. PMID:21858887

  1. Toroidal field coil torque structure

    International Nuclear Information System (INIS)

    Gaines, A.L.

    1983-01-01

    A torque structure is disclosed particularly suitable for utilization in a power reactor of the Tokamak-type, and operable therein for purposes of providing support for the toroidal field (TF) coils that comprise one of the major operating components of such a Tokamak power reactor. The subject torque structure takes the form of a frame structure that is operable to enable torque loads acting on the TF coils to be equilibrated as close to the area of force application as feasible. The aforesaid torque structure includes an intercoil structure composed of spacer wedges that are interposed between each adjacent pair of TF coils. The spacer wedges, in turn, consist of bearing plates positioned between the TF coils so as to be in contacting relation therewith and a number of cross plates that are cooperatively associated with the bearing plates so as to form therewith a rigid assembly. The intercoil structure is affixed to a segmented, membrane shell that surrounds, encloses and supports the TF coil frames. Access is had to the interior of the shell through an opening formed for this purpose in a reinforced portion of the shell. Eddy current losses are minimized by insulating the joints formed at the juncture of adjoining segments of the shell

  2. Self-assembled artificial viral capsids bearing coiled-coils at the surface.

    Science.gov (United States)

    Fujita, Seiya; Matsuura, Kazunori

    2017-06-14

    In order to construct artificial viral capsids bearing complementary dimeric coiled-coils on the surface, a β-annulus peptide bearing a coiled-coil forming sequence at the C-terminus (β-annulus-coiled-coil-B) was synthesized by a native chemical ligation of a β-annulus-SBn peptide with a Cys-containing coiled-coil-B peptide. Dynamic light scattering (DLS) measurements and transmission electron microscopy (TEM) images revealed that the β-annulus-coiled-coil-B peptide self-assembled into spherical structures of about 50 nm in 10 mM Tris-HCl buffer. Circular dichroism (CD) spectra indicated the formation of the complementary coiled-coil structure on the spherical assemblies. Addition of 0.25 equivalent of the complementary coiled-coil-A peptide to the β-annulus-coiled-coil-B peptide showed the formation of spherical assemblies of 46 ± 14 nm with grains of 5 nm at the surface, whereas addition of 1 equivalent of the complementary coiled-coil-A peptide generated fibrous assemblies.

  3. Coiled-coil domains enhance the membrane association of Salmonella type III effectors.

    Science.gov (United States)

    Knodler, Leigh A; Ibarra, J Antonio; Pérez-Rueda, Ernesto; Yip, Calvin K; Steele-Mortimer, Olivia

    2011-10-01

    Coiled-coil domains in eukaryotic and prokaryotic proteins contribute to diverse structural and regulatory functions. Here we have used in silico analysis to predict which proteins in the proteome of the enteric pathogen, Salmonella enterica serovar Typhimurium, harbour coiled-coil domains. We found that coiled-coil domains are especially prevalent in virulence-associated proteins, including type III effectors. Using SopB as a model coiled-coil domain type III effector, we have investigated the role of this motif in various aspects of effector function including chaperone binding, secretion and translocation, protein stability, localization and biological activity. Compared with wild-type SopB, SopB coiled-coil mutants were unstable, both inside bacteria and after translocation into host cells. In addition, the putative coiled-coil domain was required for the efficient membrane association of SopB in host cells. Since many other Salmonella effectors were predicted to contain coiled-coil domains, we also investigated the role of this motif in their intracellular targeting in mammalian cells. Mutation of the predicted coiled-coil domains in PipB2, SseJ and SopD2 also eliminated their membrane localization in mammalian cells. These findings suggest that coiled-coil domains represent a common membrane-targeting determinant for Salmonella type III effectors. Published 2011. This article is a US Government work and is in the public domain in the USA.

  4. The structure of the GemC1 coiled coil and its interaction with the Geminin family of coiled-coil proteins

    Energy Technology Data Exchange (ETDEWEB)

    Caillat, Christophe; Fish, Alexander [The Netherlands Cancer Institute, 1066 CX Amsterdam (Netherlands); Pefani, Dafni-Eleftheria; Taraviras, Stavros; Lygerou, Zoi [University of Patras, 26505 Rio, Patras (Greece); Perrakis, Anastassis, E-mail: a.perrakis@nki.nl [The Netherlands Cancer Institute, 1066 CX Amsterdam (Netherlands)

    2015-10-31

    The GemC1 coiled-coil structure has subtle differences compared with its homologues Geminin and Idas. Co-expression experiments in cells and biophysical stability analysis of the Geminin-family coiled coils suggest that the GemC1 coiled coil alone is unstable. GemC1, together with Idas and Geminin, an important regulator of DNA-replication licensing and differentiation decisions, constitute a superfamily sharing a homologous central coiled-coil domain. To better understand this family of proteins, the crystal structure of a GemC1 coiled-coil domain variant engineered for better solubility was determined to 2.2 Å resolution. GemC1 shows a less typical coiled coil compared with the Geminin homodimer and the Geminin–Idas heterodimer structures. It is also shown that both in vitro and in cells GemC1 interacts with Geminin through its coiled-coil domain, forming a heterodimer that is more stable that the GemC1 homodimer. Comparative analysis of the thermal stability of all of the possible superfamily complexes, using circular dichroism to follow the unfolding of the entire helix of the coiled coil, or intrinsic tryptophan fluorescence of a unique conserved N-terminal tryptophan, shows that the unfolding of the coiled coil is likely to take place from the C-terminus towards the N-terminus. It is also shown that homodimers show a single-state unfolding, while heterodimers show a two-state unfolding, suggesting that the dimer first falls apart and the helices then unfold according to the stability of each protein. The findings argue that Geminin-family members form homodimers and heterodimers between them, and this ability is likely to be important for modulating their function in cycling and differentiating cells.

  5. Large coil program support structure conceptual design

    International Nuclear Information System (INIS)

    Litherland, P.S.

    1977-01-01

    The purpose of the Large Coil Program (LCP) is to perform tests on both pool boiling and force cooled superconducting toroidal field coils. The tests will attempt to approximate conditions anticipated in an ignition tokamak. The test requirements resulted in a coil support design which accommodates up to six (6) test coils and is mounted to a structure capable of resisting coil interactions. The steps leading to the present LCP coil support structure design, details on selected structural components, and the basic assembly sequence are discussed

  6. Structural and biochemical characterizations of an intramolecular tandem coiled coil protein.

    Science.gov (United States)

    Shin, Donghyuk; Kim, Gwanho; Kim, Gyuhee; Zheng, Xu; Kim, Yang-Gyun; Lee, Sangho

    2014-12-12

    Coiled coil has served as an excellent model system for studying protein folding and developing protein-based biomaterials. Most designed coiled coils function as oligomers, namely intermolecular coiled coils. However, less is known about structural and biochemical behavior of intramolecular coiled coils where coiled coil domains are covalently linked in one polypeptide. Here we prepare a protein which harbors three coiled coil domains with two short linkers, termed intramolecular tandem coiled coil (ITCC) and characterize its structural and biochemical behavior in solution. ITCC consists of three coiled coil domains whose sequences are derived from Coil-Ser and its domain swapped dimer. Modifications include positioning E (Glu) residue at "e" and K (Lys) at "g" positions throughout heptad repeats to enhance ionic interaction among its constituent coiled coil domains. Molecular modeling of ITCC suggests a compact triple helical bundle structure with the second and the third coiled coil domains forming a canonical coiled coil. ITCC exists as a mixture of monomeric and dimeric species in solution. Small-angle X-ray scattering reveals ellipsoidal molecular envelopes for both dimeric and monomeric ITCC in solution. The theoretically modeled structures of ITCC dock well into the envelopes of both species. Higher ionic strength shifts the equilibrium into monomer with apparently more compact structure while secondary structure remains unchanged. Taken together, our results suggest that our designed ITCC is predominantly monomeric structure through the enhanced ionic interactions, and its conformation is affected by the concentration of ionic species in the buffer. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. A mechanical model of retinal detachment

    International Nuclear Information System (INIS)

    Chou, Tom; Siegel, Michael

    2012-01-01

    We present a model of the mechanical and fluid forces associated with exudative retinal detachments where the retinal photoreceptor cells separate, typically from the underlying retinal pigment epithelium (RPE). By computing the total fluid volume flow arising from transretinal, vascular and RPE pump currents, we determine the conditions under which the subretinal fluid pressure exceeds the maximum yield stress holding the retina and RPE together, giving rise to an irreversible, extended retinal delamination. We also investigate localized, blister-like retinal detachments by balancing mechanical tension in the retina with both the retina–RPE adhesion energy and the hydraulic pressure jump across the retina. For detachments induced by traction forces, we find a critical radius beyond which the blister is unstable to growth. Growth of a detached blister can also be driven by inflamed lesions in which the tissue has a higher choroidal hydraulic conductivity, has insufficient RPE pump activity, or has defective adhesion bonds. We determine the parameter regimes in which the blister either becomes unstable to growth, remains stable and finite-sized, or shrinks, allowing possible healing. The corresponding stable blister radius and shape are calculated. Our analysis provides a quantitative description of the physical mechanisms involved in exudative retinal detachments and can help guide the development of retinal reattachment protocols or preventative procedures. (paper)

  8. A mechanical model of retinal detachment

    Science.gov (United States)

    Chou, Tom; Siegel, Michael

    2012-08-01

    We present a model of the mechanical and fluid forces associated with exudative retinal detachments where the retinal photoreceptor cells separate, typically from the underlying retinal pigment epithelium (RPE). By computing the total fluid volume flow arising from transretinal, vascular and RPE pump currents, we determine the conditions under which the subretinal fluid pressure exceeds the maximum yield stress holding the retina and RPE together, giving rise to an irreversible, extended retinal delamination. We also investigate localized, blister-like retinal detachments by balancing mechanical tension in the retina with both the retina-RPE adhesion energy and the hydraulic pressure jump across the retina. For detachments induced by traction forces, we find a critical radius beyond which the blister is unstable to growth. Growth of a detached blister can also be driven by inflamed lesions in which the tissue has a higher choroidal hydraulic conductivity, has insufficient RPE pump activity, or has defective adhesion bonds. We determine the parameter regimes in which the blister either becomes unstable to growth, remains stable and finite-sized, or shrinks, allowing possible healing. The corresponding stable blister radius and shape are calculated. Our analysis provides a quantitative description of the physical mechanisms involved in exudative retinal detachments and can help guide the development of retinal reattachment protocols or preventative procedures.

  9. Large Coil Program magnetic system design study

    International Nuclear Information System (INIS)

    Moses, S.D.; Johnson, N.E.

    1977-01-01

    The primary objective of the Large Coil Program (LCP) is to demonstrate the reliable operation of large superconducting coils to provide a basis for the design principles, materials, and fabrication techniques proposed for the toroidal magnets for the THE NEXT STEP (TNS) and other future tokamak devices. This paper documents a design study of the Large Coil Test Facility (LCTF) in which the structural response of the Toroidal Field (TF) Coils and the supporting structure was evaluated under simulated reactor conditions. The LCP test facility structural system consists of six TF Coils, twelve coil-to-coil torsional restraining beams (torque rings), a central bucking post with base, and a Pulse Coil system. The NASTRAN Finite Element Structural Analysis computer Code was utilized to determine the distribution of deflections, forces, and stresses for each of the TF Coils, torque rings, and the central bucking post. Eleven load conditions were selected to represent probable test operations. Pulse Coils suspended in the bore of the test coil were energized to simulate the pulsed field environment characteristic of the TNS reactor system. The TORMAC Computer Code was utilized to develop the magnetic forces in the TF Coils for each of the eleven loading conditions examined, with or without the Pulse Coils energized. The TORMAC computer program output forces were used directly as input load conditions for the NASTRAN analyses. Results are presented which demonstrate the reliability of the LCTF under simulated reactor operating conditions

  10. Coil Designs for Novel Magnetic Geometries to Cure the Divertor Heat Flux Problem for Reactors

    Science.gov (United States)

    Pekker, M.; Valanju, P.; Kotschenreuther, M.; Wiley, J. C.; Strickler, D.

    2004-11-01

    Coil designs are developed for novel magnetic divertor geometries with a second axi-symmetric x-point and flux expansion region along the separatrix. Adjacent posters describe how these lead to spreading of heat flux and the possibility of stable, complete detachment to overcome serious physics and engineering problems in reactors. The principal feasibility issue is creating, with simple coils, additional X-points on the separatrix without extensively deforming the magnetic field in the main plasma. For the spherical tokamak NSTX, we show that adding one or two poloidal coils suffices to create a divergent flux at the divertor, i.e., a new x-point. The currents and forces for the extra coils are small. We also modify ARIES ST design to show reactor feasibility. Optimized coil designs for PEGASUS, ARIES RS/AT, and a modular ITER retrofit are also being developed. For our calculations we used self consistent code FBEQ, which was used to design NSTX. We also use NCSX tools for optimization of designs with competing physics and engineering constraints.

  11. Open-coil retraction spring.

    Science.gov (United States)

    Vibhute, Pavankumar Janardan

    2011-01-01

    Sliding mechanic has become a popular method for space closure with developments in preadjusted edgewise appliance. Furthermore, various space closing auxiliaries have been developed and evaluated extensively for their clinical efficiency. Their effectiveness enhanced with optimum force magnitude and low-load deflection rate (LDR)/force decay. With the advent of NiTi springs in orthodontics, LDRs have been markedly reduced. For use of NiTi, clinician has to depend upon prefabricated closed coil springs. "Open Coil Retraction Spring (OCRS)" is developed utilizing NiTi open-coil spring for orthodontic space closure. This paper describes fabrication and clinical application of OCRS which have number of advantages. It sustains low LDR with optimum force magnitude. Its design is adjustable for desired length and force level. It is fail-safe for both activation and deactivation (i.e., it cannot be over activated, and decompression limit of open coil is also controlled by the operator, resp.). A possibility to offset the OCRS away from mucosa helps to reduce its soft-tissue impingement.

  12. Open-Coil Retraction Spring

    Directory of Open Access Journals (Sweden)

    Pavankumar Janardan Vibhute

    2011-01-01

    Full Text Available Sliding mechanic has become a popular method for space closure with developments in preadjusted edgewise appliance. Furthermore, various space closing auxiliaries have been developed and evaluated extensively for their clinical efficiency. Their effectiveness enhanced with optimum force magnitude and low-load deflection rate (LDR/force decay. With the advent of NiTi springs in orthodontics, LDRs have been markedly reduced. For use of NiTi, clinician has to depend upon prefabricated closed coil springs. “Open Coil Retraction Spring (OCRS” is developed utilizing NiTi open-coil spring for orthodontic space closure. This paper describes fabrication and clinical application of OCRS which have number of advantages. It sustains low LDR with optimum force magnitude. Its design is adjustable for desired length and force level. It is fail-safe for both activation and deactivation (i.e., it cannot be over activated, and decompression limit of open coil is also controlled by the operator, resp.. A possibility to offset the OCRS away from mucosa helps to reduce its soft-tissue impingement.

  13. Finite element coiled cochlea model

    Science.gov (United States)

    Isailovic, Velibor; Nikolic, Milica; Milosevic, Zarko; Saveljic, Igor; Nikolic, Dalibor; Radovic, Milos; Filipović, Nenad

    2015-12-01

    Cochlea is important part of the hearing system, and thanks to special structure converts external sound waves into neural impulses which go to the brain. Shape of the cochlea is like snail, so geometry of the cochlea model is complex. The simplified cochlea coiled model was developed using finite element method inside SIFEM FP7 project. Software application is created on the way that user can prescribe set of the parameters for spiral cochlea, as well as material properties and boundary conditions to the model. Several mathematical models were tested. The acoustic wave equation for describing fluid in the cochlea chambers - scala vestibuli and scala timpani, and Newtonian dynamics for describing vibrations of the basilar membrane are used. The mechanical behavior of the coiled cochlea was analyzed and the third chamber, scala media, was not modeled because it does not have a significant impact on the mechanical vibrations of the basilar membrane. The obtained results are in good agreement with experimental measurements. Future work is needed for more realistic geometry model. Coiled model of the cochlea was created and results are compared with initial simplified coiled model of the cochlea.

  14. Wedding ring shaped excitation coil

    Science.gov (United States)

    MacLennan, Donald A.; Tsai, Peter

    2001-01-01

    A high frequency inductively coupled electrodeless lamp includes an excitation coil with an effective electrical length which is less than one half wavelength of a driving frequency applied thereto, preferably much less. The driving frequency may be greater than 100 MHz and is preferably as high as 915 MHz. Preferably, the excitation coil is configured as a non-helical, semi-cylindrical conductive surface having less than one turn, in the general shape of a wedding ring. At high frequencies, the current in the coil forms two loops which are spaced apart and parallel to each other. Configured appropriately, the coil approximates a Helmholtz configuration. The lamp preferably utilizes an bulb encased in a reflective ceramic cup with a pre-formed aperture defined therethrough. The ceramic cup may include structural features to aid in alignment and/or a flanged face to aid in thermal management. The lamp head is preferably an integrated lamp head comprising a metal matrix composite surrounding an insulating ceramic with the excitation integrally formed on the ceramic. A novel solid-state oscillator preferably provides RF power to the lamp. The oscillator is a single active element device capable of providing over 70 watts of power at over 70% efficiency.

  15. PDX toroidal field coils stress analysis

    International Nuclear Information System (INIS)

    Nikodem, Z.D.; Smith, R.A.

    1975-01-01

    A method used in the stress analysis of the PDX toroidal field coil is developed. A multilayer coil design of arbitrary dimensions in the shape of either a circle or an oval is considered. The analytical model of the coil and the supporting coil case with connections to the main support structure is analyzed using the finite element technique. The three dimensional magnetic fields and the non-uniform body forces which are a loading condition on a coil due to toroidal and poloidal fields are calculated. The method of analysis permits rapid and economic evaluations of design changes in coil geometry as well as in coil support structures. Some results pertinent to the design evolution and their comparison are discussed. The results of the detailed stress analysis of the final coil design due to toroidal field, poloidal field and temperature loads are presented

  16. Design and modelling of a SMES coil

    Energy Technology Data Exchange (ETDEWEB)

    Yuan Weijia; Campbell, A M; Coombs, T A, E-mail: wy215@cam.ac.u [EPEC Superconductivity group, Engineering Department, 9 JJ Thomson Avenue, Cambridge, CB3 0FA (United Kingdom)

    2010-06-01

    The design of a Superconducting Magnetic Energy Storage (SMES) coil wound by coated conductors has been presented. Based on an existing model for coated conductor pancake coils, this paper analysed the magnetic field and current density distribution of the coil at two different operation temperatures, 77K and 22K. A comparison table of the critical currents and AC losses at these two temperatures has been presented. Several steps to improve the transport current of the coil have been suggested as well.

  17. Bow-shaped toroidal field coils

    International Nuclear Information System (INIS)

    Bonanos, P.

    1981-05-01

    Design features of Bow-Shaped Toroidal Field Coils are described and compared with circular and D shaped coils. The results indicate that bow coils can produce higher field strengths, store more energy and be made demountable. The design offers the potential for the production of ultrahigh toroidal fields. Included are representative coil shapes and their engineering properties, a suggested structural design and an analysis of a specific case

  18. Nested Surface Coils for Multinuclear NMR

    OpenAIRE

    Magill, Arthur; Gruetter, Rolf

    2011-01-01

    This article introduces the design of surface coils for multinuclear applications. The relative sensitivities of several NMR-visible nuclei of biological interest are considered, and the motivations to operate an RF coil at multiple frequencies, both sequentially and simultaneously, are reviewed. The design of nested surface coils is then developed. Magnetic fields generated by planar loop and butterfly coils are first introduced. The benefits of quadrature design are briefly considered, and ...

  19. Raised intraocular pressure and recurrence of retinal detachment as complications of external retinal detachment surgery

    International Nuclear Information System (INIS)

    Jawwad, M.; Khan, B.; Shah, M.A.; Qayyum, I.; Aftab, M.; Qayyum, I.

    2015-01-01

    Patients with Rhegmatogenous retinal detachment may develop raised intraocular pressure and recurrence of retinal detachment when they undergo external retinal detachment surgery. The present study was conducted to determine the postoperative rise in intraocular pressure (IOP) and recurrence of retinal detachment. Methods: The present descriptive study was conducted at Eye department of Lady Reading Hospital, Peshawar on 25 patients of both genders from August 2012 to July 2014. Results: Of the 25 patients, 18 (72%) developed raised IOP in the immediate postoperative period; this figure decreased to 12 (48%) at one week. Following medical or surgical intervention in these 12 cases, there was only 1 (4%) case with mildly raised IOP at two weeks postoperative. Five (20%) cases developed recurrent retinal detachment which later resolved with treatment. There were no significant differences by age or gender. Conclusion: External Retinal Detachment Surgery raised intraocular pressure postoperatively and caused recurrence of retinal detachment. These complications were treated medically and surgically with resolution within two weeks. (author)

  20. Plasmodium vivax antigen discovery based on alpha-helical coiled coil protein motif

    DEFF Research Database (Denmark)

    Céspedes, Nora; Habel, Catherine; Lopez-Perez, Mary

    2014-01-01

    Protein α-helical coiled coil structures that elicit antibody responses, which block critical functions of medically important microorganisms, represent a means for vaccine development. By using bioinformatics algorithms, a total of 50 antigens with α-helical coiled coil motifs orthologous to Pla...

  1. Are coiled-coils of dimeric kinesins unwound during their walking on microtubule?

    Science.gov (United States)

    Duan, Zhao-Wen; Xie, Ping; Li, Wei; Wang, Peng-Ye

    2012-01-01

    Dimeric kinesin motor proteins such as homodimeric kinesin-1, homodimeric Ncd and heterodimeric Kar3/Vik1are composed of two head domains which are connected together by a rod-shaped, coiled-coil stalk. Despite the extensive and intensive studies on structures, kinetics, dynamics and walking mechanism of the dimers, whether their coiled-coils are unwound or not during their walking on the microtubule is still an unclear issue. Here, we try to clarify this issue by using molecular dynamics simulations. Our simulation results showed that, for Ncd, a large change in potential of mean force is required to unwind the coiled-coil by only several pairs of residues. For both Ncd and kinesin-1, the force required to initiate the coiled-coil unwinding is larger than that required for unfolding of the single [Formula: see text]-helix that forms the coiled-coil or is larger than that required to unwind the DNA duplex, which is higher than the unbinding force of the kinesin head from the microtubule in strong microtubule-binding states. Based on these results and the comparison of the sequence between the coiled-coil of Kar3/Vik1 and those of Ncd and kinesin-1, it was deduced that the coiled-coil of the Kar3/Vik1 should also be very stable. Thus, we concluded that the coiled-coils of kinesin-1, Ncd and Kar3/Vik1 are almost impossible to unwind during their walking on the microtubule.

  2. Split Coil Forms for Rotary Transformers

    Science.gov (United States)

    Mclyman, C. W. T.

    1982-01-01

    Split cores for rotor and stator windings of rotary transformer mounted around their respective coils (which are in bobbins) and cemented together. This arrangement simplifies winding of stator coil to go in a slot in inner diameter of stator coil. One practical application of rotary transformers fabricated according to this technique is for centrifuges, in which conventional sliprings are of uncertain reliability.

  3. The umbilical coiling index in normal pregnancy

    NARCIS (Netherlands)

    van Diik, C. C.; Franx, A.; de Laat, M. W. M.; Bruinse, H. W.; Visser, G. H. A.; Nikkels, P. G. J.

    2002-01-01

    To provide reference values for the umbilical coiling index in uncomplicated pregnancy. Umbilical cords were collected from livebom singleton infants born after uncomplicated pregnancies. The umbilical coiling index (UCI) was calculated as the number of coils divided by the cord length in

  4. The umbilical coiling index in complicated pregnancy

    NARCIS (Netherlands)

    de Laat, Monique W. M.; van Alderen, Elise D.; Franx, Arie; Visser, Gerard H. A.; Bots, Michiel L.; Nikkels, Peter G. J.

    2007-01-01

    To evaluate umbilical cord coiling in pregnancies with adverse outcome. Umbilical cords and hospital records of 565 consecutive cases with an indication for histological examination of the placenta were studied. The umbilical coiling index (UCI) was determined as the number of complete coils divided

  5. Development of SMART CRDM Coil Design

    International Nuclear Information System (INIS)

    Lee, Jae Seon; Kim, Tae Wan; Choi, Suhn; Park, Hee June

    2011-01-01

    A control rod drive mechanism (CRDM) is an electromagnetic device which drives a control rod assembly linearly to regulate reactivity of a nuclear core. Driving force is electromagnetic force generated from coils installed outside of a motor housing. The magnetic parts of a motor assembly installed inside of a motor housing are magnetized when a coil is activated, and adhere to each other to produce latching or driving force as a result. A coil assembly consists of a lifting coil, a movable latch coil and a stationary latch coil as shown in Fig. 1. The latch coils make a drive shaft engaged with or released from latches, and the lift coil makes a drive shaft and a control rod assembly move up or drop. A CRDM control system supplies controlled electric current to a specified coil in order, and then a control rod assembly moves up or down. The coil assembly for SMART CRDM has been developed based on the design concept of a coil assembly for control element drive mechanism (CEDM) of the OPR1000, and modified to satisfy dedicated design requirements for SMART reactor. Some of representative design requirements are the lifting capacity of 3200N which is greater, the lifting step of 15.875mm which is longer than that for CEDM, and one step driving instead of two step driving. Design process through an electromagnetic analysis for a lift coil is described herein as a representative example, and representative results of the analysis are presented

  6. Yttrium-90 Resin Microsphere Radioembolization Using an Antireflux Catheter: An Alternative to Traditional Coil Embolization for Nontarget Protection

    Energy Technology Data Exchange (ETDEWEB)

    Morshedi, Maud M., E-mail: maud.morshedi@my.rfums.org; Bauman, Michael, E-mail: mbauman@ucsd.edu; Rose, Steven C., E-mail: scrose@ucsd.edu; Kikolski, Steven G., E-mail: skikolski@gmail.com [University of California San Diego Health Sciences, Radiology Department, University of California San Diego Medical Center (United States)

    2015-04-15

    PurposeSerious complications can result from nontarget embolization during yttrium-90 (Y-90) transarterial radioembolization. Hepatoenteric artery coil embolization has been traditionally performed to prevent nontarget radioembolization. The U.S. Food and Drug Administration–approved Surefire Infusion System (SIS) catheter, designed to prevent reflux, is an alternative to coils. The hypothesis that quantifiable SIS procedural parameters are comparable to coil embolization was tested.MethodsFourteen patients aged 36–79 years with colorectal, neuroendocrine, hepatocellular, and other predominantly bilobar hepatic tumors who underwent resin microsphere Y-90 radioembolization using only the SIS catheter (n = 7) versus only detachable coils (n = 7) for nontarget protection were reviewed retrospectively. Procedure time, fluoroscopy time, contrast dose, radiation dose, and cost were evaluated.ResultsMultivariate analysis identified significant cohort differences in the procedural parameters evaluated (F(10, 3) = 10.39, p = 0.04). Between-group comparisons of the pretreatment planning procedure in the SIS catheter group compared to the coil embolization group demonstrated a significant reduction in procedure time (102.6 vs. 192.1 min, respectively, p = 0.0004), fluoroscopy time (14.3 vs. 49.7 min, respectively, p = 0.0016), and contrast material dose (mean dose of 174.3 vs. 265.0 mL, respectively, p = 0.0098). Procedural parameters were not significantly different between the two groups during subsequent dose delivery procedures. Overall cost of combined first-time radioembolization procedures was significantly less in the SIS group ($4252) compared to retrievable coil embolization ($11,123; p = 0.001).ConclusionThe SIS catheter results in a reduction in procedure time, fluoroscopy time, and contrast material dose and may be an attractive cost-effective alternative to detachable coil embolization for prevention of nontarget radioembolization.

  7. Modular assembly of a protein nanotriangle using orthogonally interacting coiled coils.

    Science.gov (United States)

    Park, Won Min; Bedewy, Mostafa; Berggren, Karl K; Keating, Amy E

    2017-09-05

    Synthetic protein assemblies that adopt programmed shapes would support many applications in nanotechnology. We used a rational design approach that exploits the modularity of orthogonally interacting coiled coils to create a self-assembled protein nanotriangle. Coiled coils have frequently been used to construct nanoassemblies and materials, but rarely with successful prior specification of the resulting structure. We designed a heterotrimer from three pairs of heterodimeric coiled coils that mediate specific interactions while avoiding undesired crosstalk. Non-associating pairs of coiled-coil units were strategically fused to generate three chains that were predicted to preferentially form the heterotrimer, and a rational annealing process led to the desired oligomer. Extensive biophysical characterization and modeling support the formation of a molecular triangle, which is a shape distinct from naturally occurring supramolecular nanostructures. Our approach can be extended to design more complex nanostructures using additional coiled-coil modules, other protein parts, or templated surfaces.

  8. The clear and dark sides of water: influence on the coiled coil folding domain.

    Science.gov (United States)

    Vajda, Tamás; Perczel, András

    2016-06-01

    The essential role of water in extra- and intracellular coiled coil structures of proteins is critically evaluated, and the different protein types incorporating coiled coil units are overviewed. The following subjects are discussed: i) influence of water on the formation and degradation of the coiled coil domain together with the stability of this conformer type; ii) the water's paradox iii) design of coiled coil motifs and iv) expert opinion and outlook is presented. The clear and dark sides refer to the positive and negative aspects of the water molecule, as it may enhance or inhibit a given folding event. This duplicity can be symbolized by the Roman 'Janus-face' which means that water may facilitate and stimulate coiled coil structure formation, however, it may contribute to the fatal processes of oligomerization and amyloidosis of the very same polypeptide chain.

  9. Scaffolds, levers, rods and springs: diverse cellular functions of long coiled-coil proteins.

    Science.gov (United States)

    Rose, A; Meier, I

    2004-08-01

    Long alpha-helical coiled-coil proteins are involved in a variety of organizational and regulatory processes in eukaryotic cells. They provide cables and networks in the cyto- and nucleoskeleton, molecular scaffolds that organize membrane systems, motors, levers, rotating arms and possibly springs. A growing number of human diseases are found to be caused by mutations in long coiled-coil proteins. This review summarizes our current understanding of the multifaceted group of long coiled-coil proteins in the cytoskeleton, nucleus, Golgi and cell division apparatus. The biophysical features of coiled-coil domains provide first clues toward their contribution to the diverse protein functions and promise potential future applications in the area of nanotechnology. Combining the power of fully sequenced genomes and structure prediction algorithms, it is now possible to comprehensively summarize and compare the complete inventory of coiled-coil proteins of different organisms.

  10. Spectroscopic investigations of divertor detachment in TCV

    Directory of Open Access Journals (Sweden)

    K. Verhaegh

    2017-08-01

    The inferred magnitude of recombination is small compared to the target ion current at the time detachment (particle flux drop starts at the target. However, recombination may be having more localized effects (to a flux tube which we cannot discern at this time. Later, at the highest densities achieved, the total recombination does reach levels similar to the particle flux.

  11. [Retinal detachment with retinoschisis--case report].

    Science.gov (United States)

    Cristescu, R; Muşat, O; Toma, Oana; Coma, Corina; Gabej, Ioana; Burcea, M

    2013-01-01

    We present the case of a 43 year old patient diagnosed with rhegmatogenous retinal detachment and retinoschizis, a rare case of disease association. Surgery is recommended and we practice 23 gauge vitrectomy, laser retinopexy, criopexy in the periphery and internal heavy oil tamponade. Postoperatory evolution was favorable.

  12. Shoreline response to detached breakwaters in prototype

    NARCIS (Netherlands)

    Khuong, T.C.

    2016-01-01

    An accurate prediction of shoreline changes behind detached breakwaters is, in regard to the adjustment to the environmental impact, still a challenge for designers and coastal managers. This research is expected to fill the gaps in the estimation of shoreline changes by developing new and

  13. Coil Migration through a Neuroform 3 Stent during Endovascular Coiling. A Case Report.

    LENUS (Irish Health Repository)

    O'Hare, A

    2009-07-29

    Summary: A 43-year-old woman attended for stent assisted coiling. A Neuroform 30 x 4.5 mm stent had been successfully placed over the left periophthalmic aneurysm. During the coiling the first coil migrated through the crowns in the stent, lodging at the MCA bifurcation. We believe that the coil herniated through the overlying stent due to the carotid siphon curvature and the open cell design. Furthermore the distal markers of the stent impeded coil extraction with a MERCI device.

  14. An inflatable surface coil for rectal imaging

    International Nuclear Information System (INIS)

    Martin, J.F.; Hajek, P.C.; Baker, L.L.; Gylys-Morin, V.; Mattrey, R.F.

    1986-01-01

    Surface coils have become ubiquitous in MR imaging of the body because of substantial gains in signal-to-noise ratio. Unfortunately, there are some anatomic regions, such as the prostate, for which surface coils have insufficient depth sensitivity. The authors have developed an inflatable, distributed capacitance, passively decoupled surface coil which is collapsed for insertion and reinflated for imaging. Images of the prostate are dramatically improved due to proximity of the coil. Lesions in cadaver specimens were observed which were not seen with body coil imaging. Clinical trials are expected to begin in September

  15. Repair of Traumatic Rhegmatogenous Retinal Detachment Combined with Congenital Falciform Retinal Detachment

    Directory of Open Access Journals (Sweden)

    Fukutaro Mano

    2018-01-01

    Full Text Available Purpose: To report a case of surgical repair of traumatic rhegmatogenous retinal detachment combined with congenital falciform retinal detachment (FRD. Methods: A retrospective case report. Results: A 36-year-old man with traumatic rhegmatogenous retinal detachment complicating a previously known FRD was successfully treated despite residual FRD following pars plana lensectomy, vitrectomy, and encircling scleral buckling. His best corrected visual acuity improved from hand motion at 50 cm to 20/1,000. Conclusion: We concluded that the root of the FRD is susceptible to trauma because of the contraction of fibrovascular tissue. The early intervention of modern vitrectomy to traumatic rhegmatogenous retinal detachment complicating a previously known FRD is an important consideration for enhanced quality of care and optimal patient outcomes.

  16. Pulse coil concepts for the LCP Facility

    International Nuclear Information System (INIS)

    Nelson, B.E.; Burn, P.B.

    1977-01-01

    The pulse coils described in this paper are resistive copper magnets driven by time-varying currents. They are included in the Large Coil Test Facility (LCTF) portion of the Large Coil Program (LCP) to simulate the pulsed field environment of the toroidal coils in a tokamak reactor. Since TNS (a 150 sec, 5MA, igniting tokamak) and the Oak Ridge EPR (Experimental Power Reactor) are representative of the first tokamaks to require the technology developed in LCP, the reference designs for these machines, especially TNS, are used to derive the magnetic criteria for the pulse coils. This criteria includes the magnitude, distribution, and rate of change of pulsed fields in the toroidal coil windings. Three pulse coil concepts are evaluated on the basis of magnetic criteria and factors such as versatility of design, ease of fabrication and cost of operation. The three concepts include (1) a pair of poloidal coils outside the LCTF torus, (2) a single poloidal coil threaded through the torus, and (3) a pair of vertical axis coil windings inside the bore of one or more of the toroidal test coils

  17. Embolotherapy of an Arterioportal Fistula

    International Nuclear Information System (INIS)

    Chen, Qi; Tack, Carl; Morcos, Morcos; Ruggiero, Mary Ann; Schlossberg, Peter; Fogel, Joshua; Weng Lijun; Farkas, Jeffrey

    2007-01-01

    We present a complex case of a splanchnic arterioportal vein fistula in a patient who presented with weight loss, abdominal pain, diarrhea, and pancreatitis. We report successful use of the Guglielmi Detachable Coil (GDC) and N-butyl cyanoacrylate glue for the therapeutic embolization of the fistula between the superior mesenteric artery, the common hepatic artery, and the portal vein. On the day following the procedure, the patient reported total remission of the abdominal pain and diarrhea. These results were maintained at 3 months follow-up

  18. Coiled transmission line pulse generators

    Science.gov (United States)

    McDonald, Kenneth Fox

    2010-11-09

    Methods and apparatus are provided for fabricating and constructing solid dielectric "Coiled Transmission Line" pulse generators in radial or axial coiled geometries. The pour and cure fabrication process enables a wide variety of geometries and form factors. The volume between the conductors is filled with liquid blends of monomers, polymers, oligomers, and/or cross-linkers and dielectric powders; and then cured to form high field strength and high dielectric constant solid dielectric transmission lines that intrinsically produce ideal rectangular high voltage pulses when charged and switched into matched impedance loads. Voltage levels may be increased by Marx and/or Blumlein principles incorporating spark gap or, preferentially, solid state switches (such as optically triggered thyristors) which produce reliable, high repetition rate operation. Moreover, these Marxed pulse generators can be DC charged and do not require additional pulse forming circuitry, pulse forming lines, transformers, or an a high voltage spark gap output switch. The apparatus accommodates a wide range of voltages, impedances, pulse durations, pulse repetition rates, and duty cycles. The resulting mobile or flight platform friendly cylindrical geometric configuration is much more compact, light-weight, and robust than conventional linear geometries, or pulse generators constructed from conventional components. Installing additional circuitry may accommodate optional pulse shape improvements. The Coiled Transmission Lines can also be connected in parallel to decrease the impedance, or in series to increase the pulse length.

  19. Convergently-evolved structural anomalies in the coiled coil domains of insect silk proteins.

    Science.gov (United States)

    Sutherland, Tara D; Trueman, Holly E; Walker, Andrew A; Weisman, Sarah; Campbell, Peter M; Dong, Zhaoming; Huson, Mickey G; Woodhead, Andrea L; Church, Jeffrey S

    2014-06-01

    The use of coiled coil proteins as the basis of silk materials is an engineering solution that has evolved convergently in at least five insect lineages-the stinging hymenopterans (ants, bees, hornets), argid sawflies, fleas, lacewings, and praying mantises-and persisted throughout large radiations of these insect families. These coiled coil silk proteins share a characteristic distinct from other coiled coil proteins, in that they are fabricated into solid materials after accumulating as highly concentrated solutions within dedicated glands. Here, we relate the amino acid sequences of these proteins to the secondary and tertiary structural information available from biophysical methods such as X-ray scattering, nuclear magnetic resonance and Raman spectroscopy. We investigate conserved and convergently evolved features within these proteins and compare these to the features of classic coiled coil proteins including tropomyosin and leucine zippers. Our analysis finds that the coiled coil domains of insect silk proteins have several common structural anomalies including a high prevalence of alanine residues in core positions. These atypical features of the coiled coil fibrous proteins - which likely produce deviations from canonical coiled-coil structure - likely exist due to selection pressures related to the process of silk fabrication and the final function of the proteins. Crown Copyright © 2014. Published by Elsevier Inc. All rights reserved.

  20. Structural implications of conserved aspartate residues located in tropomyosin's coiled-coil core.

    Science.gov (United States)

    Moore, Jeffrey R; Li, Xiaochuan; Nirody, Jasmine; Fischer, Stefan; Lehman, William

    2011-09-01

    Polar residues lying between adjacent α-helical chains of coiled-coils often contribute to coiled-coil curvature and flexibility, while more typical core hydrophobic residues anneal the chains together. In tropomyosins, ranging from smooth and skeletal muscle to cytoplasmic isoforms, a highly conserved Asp at residue 137 places negative charges within the tropomyosin coiled-coil core in a position which may affect the conformation needed for tropomyosin binding and regulatory movements on actin. Proteolytic susceptibility suggested that substituting a canonical Leu for the naturally occurring Asp at residue 137 increases inter-chain rigidity by stabilizing the tropomyosin coiled-coil. Using molecular dynamics, we now directly assess changes in coiled-coil curvature and flexibility caused by such mutants. Although the coiled-coil flexibility is modestly diminished near the residue 137 mutation site, as expected, a delocalized increase in flexibility along the overall coiled-coil is observed. Even though the average shape of the D137L tropomyosin is straighter than that of wild-type tropomyosin, it is still capable of binding actin due to this increase in flexibility. We conclude that the conserved, non-canonical Asp-137 destabilizes the local structure resulting in a local flexible region in the middle of tropomyosin that normally is important for tropomyosin steady-state equilibrium position on actin.

  1. Exploring alternate states and oligomerization preferences of coiled-coils by de novo structure modeling.

    Science.gov (United States)

    Rämisch, Sebastian; Lizatović, Robert; André, Ingemar

    2015-02-01

    Homomeric coiled-coils can self-assemble into a wide range of structural states with different helix topologies and oligomeric states. In this study, we have combined de novo structure modeling with stability calculations to simultaneously predict structure and oligomeric states of homomeric coiled-coils. For dimers an asymmetric modeling protocol was developed. Modeling without symmetry constraints showed that backbone asymmetry is important for the formation of parallel dimeric coiled-coils. Collectively, our results demonstrate that high-resolution structure of coiled-coils, as well as parallel and antiparallel orientations of dimers and tetramers, can be accurately predicted from sequence. De novo modeling was also used to generate models of competing oligomeric states, which were used to compare stabilities and thus predict the native stoichiometry from sequence. In a benchmark set of 33 coiled-coil sequences, forming dimers to pentamers, up to 70% of the oligomeric states could be correctly predicted. The calculations demonstrated that the free energy of helix folding could be an important factor for determining stability and oligomeric state of homomeric coiled-coils. The computational methods developed here should be broadly applicable to studies of sequence-structure relationships in coiled-coils and the design of higher order assemblies with improved oligomerization specificity. © 2014 Wiley Periodicals, Inc.

  2. Growth Factor Identity Is Encoded by Discrete Coiled-Coil Rotamers in the EGFR Juxtamembrane Region.

    Science.gov (United States)

    Doerner, Amy; Scheck, Rebecca; Schepartz, Alanna

    2015-06-18

    Binding of transforming growth factor α (TGF-α) to the epidermal growth factor receptor (EGFR) extracellular domain is encoded through the formation of a unique antiparallel coiled coil within the juxtamembrane segment. This new coiled coil is an "inside-out" version of the coiled coil formed in the presence of epidermal growth factor (EGF). A third, intermediary coiled-coil interface is formed in the juxtamembrane region when EGFR is stimulated with betacellulin. The seven growth factors that activate EGFR in mammalian systems (EGF, TGF-α, epigen, epiregulin, betacellulin, heparin-binding EGF, and amphiregulin) fall into distinct categories in which the structure of the coiled coil induced within the juxtamembrane region correlates with cell state. The observation that coiled-coil state tracks with the downstream signaling profiles for each ligand provides evidence for growth factor functional selectivity by EGFR. Encoding growth factor identity in alternative coiled-coil rotamers provides a simple and elegant method for communicating chemical information across the plasma membrane. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. A repeated coiled-coil interruption in the Escherichia coli condensin MukB.

    Science.gov (United States)

    Weitzel, Christopher S; Waldman, Vincent M; Graham, Travis A; Oakley, Martha G

    2011-12-09

    MukB, a divergent structural maintenance of chromosomes (SMC) protein, is important for chromosome segregation and condensation in Escherichia coli and other γ-proteobacteria. MukB and canonical SMC proteins share a common five-domain structure in which globular N- and C-terminal regions combine to form an ATP-binding-cassette-like ATPase domain. This ATPase domain is connected to a central, globular dimerization domain by a long antiparallel coiled coil. The structures of both globular domains have been solved recently. In contrast, little is known about the coiled coil, in spite of its clear importance for SMC function. Recently, we identified interacting regions on the N- and C-terminal halves of the MukB coiled coil through photoaffinity cross-linking experiments. On the basis of these low-resolution experimental constraints, phylogenetic data, and coiled-coil prediction analysis, we proposed a preliminary model in which the MukB coiled coil is divided into multiple segments. Here, we use a disulfide cross-linking assay to detect paired residues on opposite strands of MukB's coiled coil. This method provides accurate register data and demonstrates the presence of at least five coiled-coil segments in this domain. Moreover, these studies show that the segments are interrupted by a repeated, unprecedented deviation from canonical coiled-coil structure. These experiments provide a sufficiently detailed view of the MukB coiled coil to allow rational manipulation of this region for the first time, opening the door for structure-function studies of this domain. Copyright © 2011 Elsevier Ltd. All rights reserved.

  4. Remote maintenance of tandem mirror hybrid coils

    International Nuclear Information System (INIS)

    Dietz, L.P.

    1983-01-01

    Hybrid Coils (superconducting coils with normal conducting inserts) are being employed with increasing frequency on Tandem Mirror Devices to obtain high field strengths. The normal conducting copper inserts are short lived in comparison to their encircling superconductors. It becomes desirable, therefore, to devise design features and maintenance procedures to replace the inner normal conducting coils without simultaneously replacing the longer lived (and significantly more costly) superconducting coils. The high neutron wall loadings require that the task be accomplished by remote control. The approach is to permanently mount the coil assemblies on track mounted carriages which serve, during machine operation merely as structural supports, but during maintenance procedures as moveable transport devices. The carriages incorporate all necessary provisions to facilitate remote maintenance operations and to adjust and align the coil assemblies with respect to adjacent machine components. The vacuum vessel is severed on both sides of the hybrid coil by means of a remote cutting machine. The entire coil is transported horizontally, normal to the machine axis to a nearby repair station. Prepositioned carriage mounted repair equipment at the repair station withdraws the damaged normal coil as a single entity and inserts a preassembled spare unit. The repaired hybrid coil is reassembled to the reactor. A cost and risk effective procedure has been evolved to maintain one of the more critical components of a Tandem Mirror Machine

  5. Large coil test facility conceptual design report

    International Nuclear Information System (INIS)

    Nelms, L.W.; Thompson, P.B.; Mann, T.L.

    1978-02-01

    In the development of a superconducting toroidal field (TF) magnet for The Next Step (TNS) tokamak reactor, several different TF coils, about half TNS size, will be built and tested to permit selection of a design and fabrication procedure for full-scale TNS coils. A conceptual design has been completed for a facility to test D-shaped TF coils, 2.5 x 3.5-m bore, operating at 4-6 K, cooled either by boiling helium or by forced-flow supercritical helium. Up to six coils can be accommodated in a toroidal array housed in a single vacuum tank. The principal components and systems in the facility are an 11-m vacuum tank, a test stand providing structural support and service connections for the coils, a liquid nitrogen system, a system providing helium both as saturated liquid and at supercritical pressure, coils to produce a pulsed vertical field at any selected test coil position, coil power supplies, process instrumentation and control, coil diagnostics, and a data acquisition and handling system. The test stand structure is composed of a central bucking post, a base structure, and two horizontal torque rings. The coils are bolted to the bucking post, which transmits all gravity loads to the base structure. The torque ring structure, consisting of beams between adjacent coils, acts with the bucking structure to react all the magnetic loads that occur when the coils are energized. Liquid helium is used to cool the test stand structure to 5 K to minimize heat conduction to the coils. Liquid nitrogen is used to precool gaseous helium during system cooldown and to provide thermal radiation shielding

  6. WIDE-FIELD INFRARED IMAGING: A Descriptive Review of Characteristics of Retinoschisis, Retinal Detachment, and Schisis Detachments.

    Science.gov (United States)

    Ho, Vincent Y; Wehmeier, Jarrod M; Shah, Gaurav K

    2016-08-01

    Retinoschisis and retinal detachments are primarily differentiated based on characteristic examination findings. In diagnostically challenging cases, noncontact wide-field infrared imaging can help diagnosis and visualize the extent/margins of retinoschisis, retinal detachment, or combined schisis detachments by comparing reflectivity patterns. This is a retrospective, observational, descriptive case series of 14 eyes of 14 nonconsecutive patients, ranging from 28 to 89 years old (mean 61), diagnosed with retinoschisis, retinal detachment, or schisis detachment from May 5, 2014 to March 4, 2015. Patients with secondary retinoschisis and/or retinal detachment from other causes were not included in the study. Heidelberg Wide-Field Module lens and Heidelberg Spectralis HRA+OCT machine (Heidelberg Engineering, Heidelberg, Germany) were used to obtain noncontact, wide-field infrared images on each study eye. Seven eyes with retinal detachments, four with retinoschises, and three with schisis detachments were imaged using this novel wide-field infrared technique. Retinoschisis appears light and translucent with prominent vasculature, retinal detachments appear dark and opaque, and combined retinoschisis/retinal detachment exhibit mixed reflectivity patterns. Wide-field infrared imaging provides a quick, noncontact, noninvasive method to accurately diagnose and to monitor for progression of retinoschisis, retinal detachment, or combined schisis detachments.

  7. Rhegmatogenous retinal detachment and conventional surgical treatment.

    Science.gov (United States)

    Golubovic, M

    2013-01-01

    The aim of the paper was to present the efficacy and indications for application of conventional surgical treatment of retinal detachment by using external implants, that is,application of encircling band and buckle. This study comprised patients from the University Eye Clinic in Skopje. A total of 33 patients were diagnosed and surgically treated in the period between May 2010 and August 2011. Conventional surgery was applied in smaller number of patients whose changes of the vitreous body were manifested by detachment of posterior hyaloid membrane, syneresis, with appearance of a small number of pigment cells in the vitreous body and synchysis, and the very retina was with fresh detachment without folds or epiretinal changes (that is, PVR A grade). There were a larger number of patients with more distinct proliferative changes of the vitreous body and of the retina, grades PVR B to C1-C2, and who also underwent the same surgical approach. Routine ophthalmologic examinations were performed, including: determination of visual acuity by Snellen's optotypes, determination of eye pressure with Schiotz's tonometer, examination of anterior segment on biomicroscopy, indirect biomicroscopy of posterior eye segment (vitreous body and retina) and examination on biomicroscopy with Goldmann prism, B scan echography of the eyes before and after surgical treatment. Conventional treatment was used by external application of buckle or application of buckle and encircling band. In case of one break, radial buckle was applied and in case of multiple breaks in one quadrant limbus parallel buckle was applied. Besides buckle, encircling band was applied in patients with total or subtotal retinal detachment with already present distinct changes in the vitreous body (PVR B or C1-C2) and degenerative changes in the vitreous body. Breaks were closed with cryopexy. The results obtained have shown that male gender was predominant and that the disease was manifested in younger male adults

  8. Identifying subsurface detachment defects by acoustic tracing

    Czech Academy of Sciences Publication Activity Database

    Sklodowski, R.; Drdácký, Miloš; Sklodowski, M.

    2013-01-01

    Roč. 56, June (2013), s. 56-64 ISSN 0963-8695 R&D Projects: GA ČR(CZ) GBP105/12/G059 Institutional support: RVO:68378297 Keywords : acoustic excitation * plaster detachment defects * frequency response * inspection systems * signal processing Subject RIV: JN - Civil Engineering Impact factor: 1.717, year: 2013 http://www.sciencedirect.com/science/article/pii/S0963869513000303

  9. Tonic shock induces detachment of Giardia lamblia.

    Directory of Open Access Journals (Sweden)

    Wendy R Hansen

    Full Text Available BACKGROUND: The parasite Giardia lamblia must remain attached to the host small intestine in order to proliferate and subsequently cause disease. However, little is known about the factors that may cause detachment in vivo, such as changes in the aqueous environment. Osmolality within the proximal small intestine can vary by nearly an order of magnitude between host fed and fasted states, while pH can vary by several orders of magnitude. Giardia cells are known to regulate their volume when exposed to changes in osmolality, but the short-timescale effects of osmolality and pH on parasite attachment are not known. METHODOLOGY AND PRINCIPAL FINDINGS: We used a closed flow chamber assay to test the effects of rapid changes in media osmolality, tonicity, and pH on Giardia attachment to both glass and C2(Bbe-1 intestinal cell monolayer surfaces. We found that Giardia detach from both surfaces in a tonicity-dependent manner, where tonicity is the effective osmolality experienced by the cell. Detachment occurs with a characteristic time constant of 25 seconds (SD = 10 sec, n = 17 in both hypo- and hypertonic media but is otherwise insensitive to physiologically relevant changes in media composition and pH. Interestingly, cells that remain attached are able to adapt to moderate changes in tonicity. By exposing cells to a timed pattern of tonicity variations and adjustment periods, we found that it is possible to maximize the tonicity change experienced by the cells, overcoming the adaptive response and resulting in extensive detachment. CONCLUSIONS AND SIGNIFICANCE: These results, conducted with human-infecting Giardia on human intestinal epithelial monolayers, highlight the ability of Giardia to adapt to the changing intestinal environment and suggest new possibilities for treatment of giardiasis by manipulation of tonicity in the intestinal lumen.

  10. The prognosis of retinal detachment due to lattice degeneration.

    Science.gov (United States)

    Benson, W E; Morse, P H

    1978-09-01

    In a series of 553 consecutive retinal detachments, 29% (120) were due to lattice degeneration. Forty-five percent of these were due to atrophic holes in the lattice degeneration and 55% were due to tears caused by traction posterior to or at the end of a patch of lattice. In phakic patients, retinal detachments due to atrophic holes were most common in young myopes. Detachments due to traction tears were seen in older, less myopic patients. The incidence of massive periretinal proliferation was less (5%) in detachments due to lattice degeneration than in detachments not due to lattice degeneration (6.5%).

  11. Fibrinogen and rhegmatogenous retinal detachment: a pilot prospective study.

    Science.gov (United States)

    Theocharis, Ip

    2010-02-18

    To examine the correlation, if any, between fibrinogen plasma levels (FPL) and the clinical features of rhegmatogenous retinal detachment (RRD). FPL were measured preoperatively in 33 patients with primary RRD. Patient characteristics and detachment features such as the numbers of breaks and the extent of the detachment were recorded; No statistically significant correlation was found between FPL and the number of breaks. A statistically significant correlation was found between FPL and the extent of the RRD, even if the influence of the number of breaks was excluded. FPL correlate with retinal detachment extent, which implicates an acute inflammatory response to detachment traumatic phenomenon or a role of the fibrinogen molecule in retinal adhesiveness.

  12. The seasonal cycle of Titan's detached haze

    Science.gov (United States)

    West, Robert A.; Seignovert, Benoît; Rannou, Pascal; Dumont, Philip; Turtle, Elizabeth P.; Perry, Jason; Roy, Mou; Ovanessian, Aida

    2018-04-01

    Titan's `detached' haze, seen in Voyager images in 1980 and 1981 and monitored by the Cassini Imaging Science Subsystem (ISS) during the period 2004-2017, provides a measure of seasonal activity in Titan's mesosphere with observations over almost half of Saturn's seasonal cycle. Here we report on retrieved haze extinction profiles that reveal a depleted layer (having a diminished aerosol content), visually manifested as a gap between the main haze and a thin, detached upper layer. Our measurements show the disappearance of the feature in 2012 and its reappearance in 2016, as well as details after the reappearance. These observations highlight the dynamical nature of the detached haze. The reappearance seems congruent with earlier descriptions by climate models but more complex than previously described. It occurs in two steps, first as haze reappearing at 450 ± 20 km and one year later at 510 ± 20 km. These observations provide additional tight and valuable constraints about the underlying mechanisms, especially for Titan's mesosphere, that control Titan's haze cycle.

  13. [Scleral buckling for inferior rhegmatogenous retinal detachments].

    Science.gov (United States)

    Abdellaoui, M; Chraibi, F; Benatiya Andaloussi, I; Tahri, H

    2014-10-01

    To investigate the epidemiological, clinical, therapeutic and prognostic factors in cases of inferior rhegmatogenous retinal detachments (RD) treated by scleral buckling surgery. A retrospective chart review was performed on 45 patients (45 eyes) with inferior RD with only inferior tears (4:00-8:00), who had been treated by scleral buckling surgery over a 6-year period from 2006 to 2011. The parameters studied included patient demographics, refractive status, time until consultation, clinical exam data, treatment modalities and functional and anatomic results. Forty-five cases were included in this study (45 eyes), with an average patient age of 44.5 years (14 to 75 years) and a slight male predominance (56%). Myopia was observed in 60%. Mean time until consultation was 3.5 months. Visual acuity on admission was less than 1/10 in 53.33%. Macular detachment was found in 80%. Causative lesions were holes in 26 eyes. Proliferative vitreoretinopathy was essentially stage B in 48.9%. Scleral buckling surgery was performed in all patients, with drainage of subretinal fluid in 37.8%. Retinal reattachment was obtained in 36 eyes (80%) with a final visual acuity greater than or equal to 1/10 in 71.11%. The mean follow-up in our study was 6.62 months. Inferior retinal detachment has a predilection for young myopes. The time until consultation is often long, and extraocular surgery, although difficult, exhibits documented efficacy. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  14. The Merits of Endovascular Coil Surgery for Patients with Unruptured Intracranial Aneurysms

    Science.gov (United States)

    Park, Seong-Ho; Yim, Man-Bin

    2008-01-01

    Objective The purpose of this study was to report the morbidity, mortality, angiographic results, and merits of elective coiling of unruptured intracranial aneurysms. Methods Ninety-six unruptured aneurysms in 92 patients were electively treated with detachable coils. Eighty-one of these aneurysms were located in the anterior circulation, and 15 were located in the posterior circulation. Thirty-six aneurysms were treated in the presence of previously ruptured aneurysms that had already undergone operation. Nine unruptured aneurysms presented with symptoms of mass effect. The remaining 51 aneurysms were incidentally discovered in patients with other cerebral diseases and in individuals undergoing routine health maintenance. Angiographic and clinical outcomes and procedure-related complications were analyzed. Results Eight procedure-related untoward events (8.3%) occurred during surgery or within procedure-related hospitalization, including thromboembolism, sac perforation, and coil migration. Permanent procedural morbidity was 2.2% ; there was no mortality. Complete occlusion was achieved in 73 (76%) aneurysms, neck remnant occlusion in 18 (18.7%) aneurysms, and incomplete occlusion in five (5.2%) aneurysms. Recanalization occurred in 8 (15.4%) of 52 coiled aneurysms that were available for follow-up conventional angiography or magnetic resonance angiography over a mean period of 13.3 months. No ruptures occurred during the follow-up period (12-79 months). Conclusion Endovascular coil surgery for patients with unruptured intracranial aneurysms is characterized by low procedural mortality and morbidity and has advantages in patients with poor general health, cerebral infarction, posterior circulation aneurysms, aneurysms of the proximal internal cerebral artery, and unruptured aneurysms associated with ruptured aneurysm. For the management of unruptured aneurysms, endovascular coil surgery is considered an attractive alterative option. PMID:19096631

  15. The coiled coils of cohesin are conserved in animals, but not in yeast.

    Directory of Open Access Journals (Sweden)

    Glenn E White

    Full Text Available The SMC proteins are involved in DNA repair, chromosome condensation, and sister chromatid cohesion throughout Eukaryota. Long, anti-parallel coiled coils are a prominent feature of SMC proteins, and are thought to serve as spacer rods to provide an elongated structure and to separate domains. We reported recently that the coiled coils of mammalian condensin (SMC2/4 showed moderate sequence divergence (approximately 10-15% consistent with their functioning as spacer rods. The coiled coils of mammalian cohesins (SMC1/3, however, were very highly constrained, with amino acid sequence divergence typically <0.5%. These coiled coils are among the most highly conserved mammalian proteins, suggesting that they make extensive contacts over their entire surface.Here, we broaden our initial analysis of condensin and cohesin to include additional vertebrate and invertebrate organisms and multiple species of yeast. We found that the coiled coils of SMC1/3 are highly constrained in Drosophila and other insects, and more generally across all animal species. However, in yeast they are no more constrained than the coils of SMC2/4 and Ndc80/Nuf2p, suggesting that they are serving primarily as spacer rods.SMC1/3 functions for sister chromatid cohesion in all species. Since its coiled coils apparently serve only as spacer rods in yeast, it is likely that this is sufficient for sister chromatid cohesion in all species. This suggests an additional function in animals that constrains the sequence of the coiled coils. Several recent studies have demonstrated that cohesin has a role in gene expression in post-mitotic neurons of Drosophila, and other animal cells. Some variants of human Cornelia de Lange Syndrome involve mutations in human SMC1/3. We suggest that the role of cohesin in gene expression may involve intimate contact of the coiled coils of SMC1/3, and impose the constraint on sequence divergence.

  16. Development of a new error field correction coil (C-coil) for DIII-D

    International Nuclear Information System (INIS)

    Robinson, J.I.; Scoville, J.T.

    1995-12-01

    The C-coil recently installed on the DIII-D tokamak was developed to reduce the error fields created by imperfections in the location and geometry of the existing coils used to confine, heat, and shape the plasma. First results from C-coil experiments include stable operation in a 1.6 MA plasma with a density less than 1.0 x 10 13 cm -3 , nearly a factor of three lower density than that achievable without the C-coil. The C-coil has also been used in magnetic braking of the plasma rotation and high energy particle confinement experiments. The C-coil system consists of six individual saddle coils, each 60 degree wide toroidally, spanning the midplane of the vessel with a vertical height of 1.6 m. The coils are located at a major radius of 3.2 m, just outside of the toroidal field coils. The actual shape and geometry of each coil section varied somewhat from the nominal dimensions due to the large number of obstructions to the desired coil path around the already crowded tokamak. Each coil section consists of four turns of 750 MCM insulated copper cable banded with stainless steel straps within the web of a 3 in. x 3 in. stainless steel angle frame. The C-coil structure was designed to resist peak transient radial forces (up to 1,800 Nm) exerted on the coil by the toroidal and ploidal fields. The coil frames were supported from existing poloidal field coil case brackets, coil studs, and various other structures on the tokamak

  17. Critical evaluation of in silico methods for prediction of coiled-coil domains in proteins.

    Science.gov (United States)

    Li, Chen; Ching Han Chang, Catherine; Nagel, Jeremy; Porebski, Benjamin T; Hayashida, Morihiro; Akutsu, Tatsuya; Song, Jiangning; Buckle, Ashley M

    2016-03-01

    Coiled-coils refer to a bundle of helices coiled together like strands of a rope. It has been estimated that nearly 3% of protein-encoding regions of genes harbour coiled-coil domains (CCDs). Experimental studies have confirmed that CCDs play a fundamental role in subcellular infrastructure and controlling trafficking of eukaryotic cells. Given the importance of coiled-coils, multiple bioinformatics tools have been developed to facilitate the systematic and high-throughput prediction of CCDs in proteins. In this article, we review and compare 12 sequence-based bioinformatics approaches and tools for coiled-coil prediction. These approaches can be categorized into two classes: coiled-coil detection and coiled-coil oligomeric state prediction. We evaluated and compared these methods in terms of their input/output, algorithm, prediction performance, validation methods and software utility. All the independent testing data sets are available at http://lightning.med.monash.edu/coiledcoil/. In addition, we conducted a case study of nine human polyglutamine (PolyQ) disease-related proteins and predicted CCDs and oligomeric states using various predictors. Prediction results for CCDs were highly variable among different predictors. Only two peptides from two proteins were confirmed to be CCDs by majority voting. Both domains were predicted to form dimeric coiled-coils using oligomeric state prediction. We anticipate that this comprehensive analysis will be an insightful resource for structural biologists with limited prior experience in bioinformatics tools, and for bioinformaticians who are interested in designing novel approaches for coiled-coil and its oligomeric state prediction. © The Author 2015. Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.

  18. Numerical computational of fluid flow through a detached retina

    Science.gov (United States)

    Jiann, Lim Yeou; Ismail, Zuhaila; Shafie, Sharidan; Fitt, Alistair

    2015-02-01

    In this paper, a phenomenon of fluid flow through a detached retina is studied. Rhegmatogeneous retinal detachment happens when vitreous humour flow through a detached retina. The exact mechanism of Rhegmatogeneous retinal detachment is complex and remains incomplete. To understand the fluid flow, a paradigm mathematical model is developed and is approximated by the lubrication theory. The numerical results of the velocity profile and pressure distribution are computed by using Finite Element Method. The effects of fluid mechanical on the retinal detachment is discussed and analyzed. Based on the analysis, it is found that the retinal detachment deformation affects the pressure distribution. It is important to comprehend the development of the retinal detachment so that a new treatment method can be developed.

  19. Argonne National Laboratory superconducting pulsed coil program

    International Nuclear Information System (INIS)

    Wang, S.T.; Kim, S.H.

    1979-01-01

    The main objectives are to develop high current (approx. 100 kA) cryostable cable configurations with reasonably low ac losses, to build a demonstration pulsed coil, and to develop a rather inexpensive large fiberglass reinforced helium cryostat. A 1.5-MJ cryostable pulsed superconducting coil has been developed and constructed at ANL. The coil has a peak field of 4.5 T at an operating current of 11.0 kA. A large inexpensive plastic cryostat has been developed for testing the pulsed coil. The coil has been pulsed with a maximum dB/dt of 11 T/s. The coil was pulsed more than 4000 cycles. Detailed results of the ac loss measurements and the current sharing of the cryostability will be described

  20. Power loss problems in EXTRAP coil systems

    International Nuclear Information System (INIS)

    Lehnert, B.

    1977-02-01

    The Ohmic power loss in the coils of external ring traps is minimized with respect to the thermonuclear power production. In the case of the DT-reaction this leads to dimensions and power densities being relevant to full-scale reactors. Not only superconducting or refrigerated coil windings can thus be used, but also hot-coil systems which are operated at several hundred degrees centrigrade and form part of a steam cycle and power extraction system. For hot coils the problems of void formation and tritium regeneration have to be further examined. The high beta value leads to moderately large coil stresses. Finally, replacement and repair become simplified by the present coil geometry. (Auth.)

  1. Split-coil-system SULTAN

    International Nuclear Information System (INIS)

    Vecsey, G.

    1992-08-01

    The high field superconductor test facility SULTAN started operation successfully in May 1992. Originally designed for testing full scale conductors for the large magnets of the next generation fusion reactors, the SULTAN facility installed at PSI (Switzerland) was designed as a common venture of three European Laboratories: ENEA (Italy), ECN (Netherlands) and PSI, and built by ENEA and PSI in the framework of the Euratom Fusion Technology Program. Presently the largest facility in the world, with its superconducting split coil system generating 11 Tesla in a 0.6 m bore, it is ready now for testing superconductor samples with currents up to 50 kA at variable cooling conditions. Similar tests can be arranged also for other applications. SULTAN is offered by the European Community as a contribution to the worldwide cooperation for the next step of fusion reactor development ITER. First measurements on conductor developed by CEA (Cadarache) are now in progress. Others like those of ENEA and CERN will follow. For 1993, a test of an Italian 12 TZ model coil for fusion application is planned. SULTAN is a worldwide unique facility marking the competitive presence of Swiss technology in the field of applied superconductivity research. Based on development and design of PSI, the high field Nb 3 Sn superconductors and coils were fabricated at the works of Kabelwerke Brugg and ABB, numerous Swiss companies contributed to the success of this international effort. Financing of the Swiss contribution of SULTAN was made available by NEFF, BEW, BBW, PSI and EURATOM. (author) figs., tabs., 20 refs

  2. Radiative MRI Coil Design Using Parasitic Scatterers

    DEFF Research Database (Denmark)

    Sanchez-Heredia, Juan D.; Avendal, Johan; Bibic, Adnan

    2018-01-01

    allows for antenna design techniques to be adapted to RF coil designs. This study proposes the use of parasitic scatterers to improve the performance of an existing 7T MRI coil called the single-sided adapted dipole (SSAD) antenna. The results reveal that scatterers arranged in a Yagi fashion can...... suitable for use in high density arrays. These findings show the potential of parasitic scatterers as an effective method to improve the performance of existing radiative MRI coils....

  3. The structure of the GemC1 coiled coil and its interaction with the Geminin family of coiled-coil proteins.

    Science.gov (United States)

    Caillat, Christophe; Fish, Alexander; Pefani, Dafni Eleftheria; Taraviras, Stavros; Lygerou, Zoi; Perrakis, Anastassis

    2015-11-01

    GemC1, together with Idas and Geminin, an important regulator of DNA-replication licensing and differentiation decisions, constitute a superfamily sharing a homologous central coiled-coil domain. To better understand this family of proteins, the crystal structure of a GemC1 coiled-coil domain variant engineered for better solubility was determined to 2.2 Å resolution. GemC1 shows a less typical coiled coil compared with the Geminin homodimer and the Geminin-Idas heterodimer structures. It is also shown that both in vitro and in cells GemC1 interacts with Geminin through its coiled-coil domain, forming a heterodimer that is more stable that the GemC1 homodimer. Comparative analysis of the thermal stability of all of the possible superfamily complexes, using circular dichroism to follow the unfolding of the entire helix of the coiled coil, or intrinsic tryptophan fluorescence of a unique conserved N-terminal tryptophan, shows that the unfolding of the coiled coil is likely to take place from the C-terminus towards the N-terminus. It is also shown that homodimers show a single-state unfolding, while heterodimers show a two-state unfolding, suggesting that the dimer first falls apart and the helices then unfold according to the stability of each protein. The findings argue that Geminin-family members form homodimers and heterodimers between them, and this ability is likely to be important for modulating their function in cycling and differentiating cells.

  4. Manufacturing development of the Westinghouse Nb3Sn coil for the Large Coil Test Program

    International Nuclear Information System (INIS)

    Young, J.L.; Vota, T.L.; Singh, S.K.

    1983-01-01

    The Westinghouse Nb 3 Sn Magnet for the Oak Ridge National Laboratory Large Coil Program (LCP) is currently well into the manufacturing phase. This paper identifies the manufacturing processes and development tasks for his unique, advanced coil

  5. Effects of five-membered ring amino acid incorporation into peptides for coiled coil formation.

    Science.gov (United States)

    Oba, Makoto; Ito, Chika; Tanaka, Masakazu

    2018-03-01

    A five-membered ring amino acid (Ac 5 c), the peptides of which exhibit a preference for helical secondary structures, was introduced into peptides for the purpose of designing coiled coil peptides with high binding affinities. We prepared five types of peptides containing Ac 5 c with different numbers or at different positions. The incorporation of Ac 5 c into peptides enhanced their α-helicities; however, in contrast to our expectations, it did not result in stable coiled coil formation. The structures of side chains in hydrophobic amino acids, not α-helicities appeared to be important for stable hydrophobic interactions between peptides. Although we were unable to develop coiled coil peptides with high binding affinities, the present results will be useful for designing novel coiled coil peptides. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Transport Vesicle Tethering at the Trans Golgi Network: Coiled Coil Proteins in Action.

    Science.gov (United States)

    Cheung, Pak-Yan P; Pfeffer, Suzanne R

    2016-01-01

    The Golgi complex is decorated with so-called Golgin proteins that share a common feature: a large proportion of their amino acid sequences are predicted to form coiled-coil structures. The possible presence of extensive coiled coils implies that these proteins are highly elongated molecules that can extend a significant distance from the Golgi surface. This property would help them to capture or trap inbound transport vesicles and to tether Golgi mini-stacks together. This review will summarize our current understanding of coiled coil tethers that are needed for the receipt of transport vesicles at the trans Golgi network (TGN). How do long tethering proteins actually catch vesicles? Golgi-associated, coiled coil tethers contain numerous binding sites for small GTPases, SNARE proteins, and vesicle coat proteins. How are these interactions coordinated and are any or all of them important for the tethering process? Progress toward understanding these questions and remaining, unresolved mysteries will be discussed.

  7. A precise technique for manufacturing correction coil

    International Nuclear Information System (INIS)

    Schieber, L.

    1992-01-01

    An automated method of manufacturing correction coils has been developed which provides a precise embodiment of the coil design. Numerically controlled machines have been developed to accurately position coil windings on the beam tube. Two types of machines have been built. One machine bonds the wire to a substrate which is wrapped around the beam tube after it is completed while the second machine bonds the wire directly to the beam tube. Both machines use the Multiwire reg-sign technique of bonding the wire to the substrate utilizing an ultrasonic stylus. These machines are being used to manufacture coils for both the SSC and RHIC

  8. A Comparative Study of Orthodontic Coil Springs

    OpenAIRE

    Deepak Kumar Agarwal; Anup Razdan; Abhishek Agarwal; Preeti Bhattacharya; Ankur Gupta; D N Kapoor

    2011-01-01

    Several types of force delivering system are used to carry out tooth movement in orthodontics. Coil springs being one of them are used for the same thus requiring minimal operator manipulation. Aims and objectives : The purpose of this study was to determine the effect of wire diameter, lumen size and length of coil spring on the load produced as a function of displacement of SS and NiTi coil spring. Materials and methods : The study consisted of 60 samples of open and closed coil sprin...

  9. Thomson's Jumping Ring Over a Long Coil

    Science.gov (United States)

    Jeffery, Rondo N.; Amiri, Farhang

    2018-03-01

    The classic jumping ring apparatus consists of a coil with an iron core that extends out of the coil. A copper or aluminum ring placed over the iron core jumps upward when AC power is applied to the coil. In this paper we will examine a modified design of the jumping ring apparatus, called the "long-coil design." It allows the ring to jump upward or downward, depending on the starting position of the ring. These features shed significant light on the study of the force that causes the ring to jump.

  10. Coiled-coil driven membrane fusion: zipper-like vs. non-zipper-like peptide orientation.

    Science.gov (United States)

    Versluis, Frank; Dominguez, Juan; Voskuhl, Jens; Kros, Alexander

    2013-01-01

    Membrane fusion plays a central role in biological processes such as neurotransmission and exocytosis. An important class of proteins that induce membrane fusion are called SNARE (soluble N-ethyl malemeide sensitive factor attachment protein receptors) proteins. To induce membrane fusion, two SNARE proteins embedded in opposing membranes form a four-helix coiled-coil motif together with a third, cytoplasmic, SNARE protein. Coiled-coil formation brings the two membranes into close proximity allowing fusion to occur. Importantly, structural investigations have demonstrated that native membrane fusion only occurs when the orientation of the coiled-coil motif resembles that of a zipper. The zipper orientation arises when parallel coiled-coil formation takes place between peptides that are anchored into apposing membranes at identical termini, thereby forcing the membranes into close contact. Recently, we have designed a synthetic model for membrane fusion, which is based on a set of lipidated coiled-coil forming peptide pairs which are denoted E-K. When incorporated into liposomal membranes, coiled-coil formation between these lipidated peptides induces targeted and efficient membrane fusion of liposomes. Our model system mimics SNARE-driven membrane fusion, as it contains a coiled-coil motif which has a zipper-like orientation, similar to that of the SNARE proteins. Here we investigate whether the zipper-like orientation of the coiled-coil motifs is a prerequisite for membrane fusion in our model system. Our strategy is based on conjugation of the transmembrane anchor to either the N- or the C-terminus of peptides E and K. Whereas the use of a set of complementary peptides with the membrane anchor on identical peptide termini yields the zipper-like orientation of the coiled-coil complex, membrane anchors on opposite peptide termini results in a non-zipper-like coiled-coil orientation. Surprisingly, it was observed that efficient and targeted membrane fusion was

  11. A Non-perturbing Probe of Coiled Coil Formation Based on Electron Transfer Mediated Fluorescence Quenching.

    Science.gov (United States)

    Watson, Matthew D; Peran, Ivan; Raleigh, Daniel P

    2016-07-05

    Coiled coils are abundant in nature, occurring in ∼3% of proteins across sequenced genomes, and are found in proteins ranging from transcription factors to structural proteins. The motif continues to be an important model system for understanding protein-protein interactions and is finding increased use in bioinspired materials and synthetic biology. Knowledge of the thermodynamics of self-assembly, particularly the dissociation constant KD, is essential for the application of designed coiled coils and for understanding the in vivo specificity of natural coiled coils. Standard methods for measuring KD typically rely on concentration dependent circular dichroism (CD). Fluorescence methods are an attractive alternative; however Trp is rarely found in an interior position of a coiled coil, and appending unnatural fluorophores can perturb the system. We demonstrate a simple, non-perturbing method to monitor coiled coil formation using p-cyanophenylalanine (FCN) and selenomethionine (MSe), the Se analogue of Met. FCN fluorescence can be selectively excited and is effectively quenched by electron transfer with MSe. Both FCN and MSe represent minimally perturbing substitutions in coiled coils. MSe quenching of FCN fluorescence is shown to offer a non-perturbing method for following coiled coil formation and for accurately determining dissociation constants. The method is validated using a designed heterodimeric coiled coil. The KD deduced by fluorescence monitored titration is in excellent agreement with the value deduced from concentration dependent CD measurements to within the uncertainty of the measurement. However, the fluorescence approach requires less protein, is less time-consuming, can be applied to lower concentrations and could be applied to high throughput screens.

  12. Moving coil-based actuators

    Science.gov (United States)

    Neff, Edward A.

    2002-09-01

    SMAC Corporation manufactures a wide variety of moving coil based electric servo actuators. These actuators were developed with a specific purpose in mind: To produce tools that would make the automation of assembly easier to accomplish, tools that could perform work in much the same manner as fingers but with more precision. The design targets were: A. Variable programmable accurate positioning down to sub-micron level. B. Variable programmable accurately controlled speeds. C. Variable programmable forces from grams to kilograms. D. Multiple axis configurations to increase degrees of freedom hence flexibility. E. The ability to perform work and verify its success at the same time. F. A low cost design that could eventually compete with pneumatic devices. (SMAC is related to two large pneumatic manufacturers: SMC Corp. and Mac Valve, Inc.) It should be noted that in the past a number of designers have developed voice coil based actuators, the Stout design and patent, with its discussion of programmable force was an early inspiration. SMAC's basic electro/mechanical and software design patents number 20.

  13. Superconducting Coil of Po Dipole

    CERN Multimedia

    1983-01-01

    The Po superconducting dipole was built as a prototype beam transport magnet for the SPS extracted proton beam P0. Its main features were: coil aperture 72 mm, length 5 m, room-temperature yoke, NbTi cable conductor impregnated with solder, nominal field 4.2 T at 4.7 K (87% of critical field). It reached its nominal field without any quench.After this successful test up to its nominal field of 4.2 T, the power was not raised to reach a quench. The magnet was not installed in a beam and had no other further use. Nevertheless its construction provided knowledges and experience which became useful in the design and construction of the LHC magnets. The photo shows a detail of the inner layer winding before superposing the outer layer to form the complete coil of a pole. Worth noticing is the interleaved glass-epoxy sheet (white) with grooved channels for the flow of cooling helium. See also 8211532X.

  14. Accommodation of structural rearrangements in the huntingtin-interacting protein 1 coiled-coil domain

    Energy Technology Data Exchange (ETDEWEB)

    Wilbur, Jeremy D., E-mail: jwilbur@msg.ucsf.edu [Graduate Program in Biophysics, University of California, San Francisco, California 94143 (United States); Hwang, Peter K. [Department of Biochemistry and Biophysics, University of California, San Francisco, California 94143 (United States); Brodsky, Frances M. [The G. W. Hooper Foundation, Departments of Microbiology and Immunology and of Bioengineering and Therapeutic Sciences, University of California, San Francisco, California 94143 (United States); Department of Pharmaceutical Chemistry, University of California, San Francisco, California 94143 (United States); Fletterick, Robert J. [Department of Biochemistry and Biophysics, University of California, San Francisco, California 94143 (United States); Department of Pharmaceutical Chemistry, University of California, San Francisco, California 94143 (United States); Graduate Program in Biophysics, University of California, San Francisco, California 94143 (United States)

    2010-03-01

    Variable packing interaction related to the conformational flexibility within the huntingtin-interacting protein 1 coiled coil domain. Huntingtin-interacting protein 1 (HIP1) is an important link between the actin cytoskeleton and clathrin-mediated endocytosis machinery. HIP1 has also been implicated in the pathogenesis of Huntington’s disease. The binding of HIP1 to actin is regulated through an interaction with clathrin light chain. Clathrin light chain binds to a flexible coiled-coil domain in HIP1 and induces a compact state that is refractory to actin binding. To understand the mechanism of this conformational regulation, a high-resolution crystal structure of a stable fragment from the HIP1 coiled-coil domain was determined. The flexibility of the HIP1 coiled-coil region was evident from its variation from a previously determined structure of a similar region. A hydrogen-bond network and changes in coiled-coil monomer interaction suggest that the HIP1 coiled-coil domain is uniquely suited to allow conformational flexibility.

  15. Multicoil2: Predicting Coiled Coils and Their Oligomerization States from Sequence in the Twilight Zone

    Science.gov (United States)

    Trigg, Jason; Gutwin, Karl; Keating, Amy E.; Berger, Bonnie

    2011-01-01

    The alpha-helical coiled coil can adopt a variety of topologies, among the most common of which are parallel and antiparallel dimers and trimers. We present Multicoil2, an algorithm that predicts both the location and oligomerization state (two versus three helices) of coiled coils in protein sequences. Multicoil2 combines the pairwise correlations of the previous Multicoil method with the flexibility of Hidden Markov Models (HMMs) in a Markov Random Field (MRF). The resulting algorithm integrates sequence features, including pairwise interactions, through multinomial logistic regression to devise an optimized scoring function for distinguishing dimer, trimer and non-coiled-coil oligomerization states; this scoring function is used to produce Markov Random Field potentials that incorporate pairwise correlations localized in sequence. Multicoil2 significantly improves both coiled-coil detection and dimer versus trimer state prediction over the original Multicoil algorithm retrained on a newly-constructed database of coiled-coil sequences. The new database, comprised of 2,105 sequences containing 124,088 residues, includes reliable structural annotations based on experimental data in the literature. Notably, the enhanced performance of Multicoil2 is evident when tested in stringent leave-family-out cross-validation on the new database, reflecting expected performance on challenging new prediction targets that have minimal sequence similarity to known coiled-coil families. The Multicoil2 program and training database are available for download from http://multicoil2.csail.mit.edu. PMID:21901122

  16. Natural templates for coiled-coil biomaterials from praying mantis egg cases.

    Science.gov (United States)

    Walker, Andrew A; Weisman, Sarah; Kameda, Tsunenori; Sutherland, Tara D

    2012-12-10

    Whereas there is growing interest in producing biomaterials containing coiled-coils, relatively few studies have made use of naturally occurring fibrous proteins. In this study, we have characterized fibrous proteins used by mother praying mantises to produce an extensive covering for their eggs called an ootheca and demonstrate the production of artificial ootheca using recombinantly produced proteins. Examination of natural oothecae by infrared spectroscopy and solid-state nuclear magnetic resonance revealed the material to consist of proteins organized predominately as coiled-coils. Two structural proteins, Mantis Fibroin 1 and Mantis Fibroin 2, were identified in ootheca from each of three species. Between species, the primary sequences of both proteins had diverged considerably, but other features were tightly conserved, including low molecular weight, high abundance of Ala, Glu, Lys, and Ser, and a triblock-like architecture with extensive central coiled-coil domain. Mantis fibroin hydrophobic cores had an unusual composition containing high levels of alanine and aromatic residues. Recombinantly produced mantis fibroins folded into coiled-coils in solution and could be fabricated into solid materials with high coiled-coil content. The structural features of mantis fibroins and their straightforward recombinant production make them promising templates for the production of coiled-coil biomimetics materials.

  17. Modulation of Coiled-Coil Dimer Stability through Surface Residues while Preserving Pairing Specificity.

    Science.gov (United States)

    Drobnak, Igor; Gradišar, Helena; Ljubetič, Ajasja; Merljak, Estera; Jerala, Roman

    2017-06-21

    The coiled-coil dimer is a widespread protein structural motif and, due to its designability, represents an attractive building block for assembling modular nanostructures. The specificity of coiled-coil dimer pairing is mainly based on hydrophobic and electrostatic interactions between residues at positions a, d, e, and g of the heptad repeat. Binding affinity, on the other hand, can also be affected by surface residues that face away from the dimerization interface. Here we show how design of the local helical propensity of interacting peptides can be used to tune the stabilities of coiled-coil dimers over a wide range. By designing intramolecular charge pairs, regions of high local helical propensity can be engineered to form trigger sequences, and dimer stability is adjusted without changing the peptide length or any of the directly interacting residues. This general principle is demonstrated by a change in thermal stability by more than 30 °C as a result of only two mutations outside the binding interface. The same approach was successfully used to modulate the stabilities in an orthogonal set of coiled-coils without affecting their binding preferences. The stability effects of local helical propensity and peptide charge are well described by a simple linear model, which should help improve current coiled-coil stability prediction algorithms. Our findings enable tuning the stabilities of coiled-coil-based building modules match a diverse range of applications in synthetic biology and nanomaterials.

  18. LOGICOIL--multi-state prediction of coiled-coil oligomeric state.

    Science.gov (United States)

    Vincent, Thomas L; Green, Peter J; Woolfson, Derek N

    2013-01-01

    The coiled coil is a ubiquitous α-helical protein-structure domain that directs and facilitates protein-protein interactions in a wide variety of biological processes. At the protein-sequence level, the coiled coil is readily recognized via a conspicuous heptad repeat of hydrophobic and polar residues. However, structurally coiled coils are more complicated, existing in a wide range of oligomer states and topologies. As a consequence, predicting these various states from sequence remains an unmet challenge. This work introduces LOGICOIL, the first algorithm to address the problem of predicting multiple coiled-coil oligomeric states from protein-sequence information alone. By covering >90% of the known coiled-coil structures, LOGICOIL is a net improvement compared with other existing methods, which achieve a predictive coverage of ∼31% of this population. This leap in predictive power offers better opportunities for genome-scale analysis, and analyses of coiled-coil containing protein assemblies. LOGICOIL is available via a web-interface at http://coiledcoils.chm.bris.ac.uk/LOGICOIL. Source code, training sets and supporting information can be downloaded from the same site.

  19. Coiled-coil formation on lipid bilayers--implications for docking and fusion efficiency.

    Science.gov (United States)

    Pähler, Gesa; Panse, Cornelia; Diederichsen, Ulf; Janshoff, Andreas

    2012-12-05

    Coiled-coil formation of four different oligopeptides was characterized in solution, on hydrogels, and on membranes by employing circular dichroism spectroscopy, surface plasmon resonance spectroscopy, attenuated total reflection infrared spectroscopy, and ellipsometry. Peptide sequences rich in either glutamic acid (E: E3Cys, i-E3Cys) or lysine (K: K3Cys, i-K3Cys) were used to represent minimal mimics of eukaryotic SNARE motifs. Half of the peptides were synthesized in reverse sequence, so that parallel and antiparallel heptad coiled-coil structures were formed. Either E-peptides or K-peptides were attached covalently to phospholipid anchors via maleimide chemistry, and served as receptors for the recognition of the corresponding binding partners added to solution. Attenuated total reflection infrared spectroscopy of single bilayers confirmed the formation of coiled-coil complexes at the membrane interface. Coiled-coil formation in solution, as compared with association at the membrane surface, displays considerably larger binding constants that are largely attributed to loss of translational entropy at the interface. Finally, the fusogenicity of the various coiled-coil motifs was explored, and the results provide clear evidence that hemifusion followed by full fusion requires a parallel orientation of α-helices, whereas antiparallel oriented coiled-coil motifs display only docking. Copyright © 2012 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  20. Coiled-Coil Formation on Lipid Bilayers—Implications for Docking and Fusion Efficiency

    Science.gov (United States)

    Pähler, Gesa; Panse, Cornelia; Diederichsen, Ulf; Janshoff, Andreas

    2012-01-01

    Coiled-coil formation of four different oligopeptides was characterized in solution, on hydrogels, and on membranes by employing circular dichroism spectroscopy, surface plasmon resonance spectroscopy, attenuated total reflection infrared spectroscopy, and ellipsometry. Peptide sequences rich in either glutamic acid (E: E3Cys, i-E3Cys) or lysine (K: K3Cys, i-K3Cys) were used to represent minimal mimics of eukaryotic SNARE motifs. Half of the peptides were synthesized in reverse sequence, so that parallel and antiparallel heptad coiled-coil structures were formed. Either E-peptides or K-peptides were attached covalently to phospholipid anchors via maleimide chemistry, and served as receptors for the recognition of the corresponding binding partners added to solution. Attenuated total reflection infrared spectroscopy of single bilayers confirmed the formation of coiled-coil complexes at the membrane interface. Coiled-coil formation in solution, as compared with association at the membrane surface, displays considerably larger binding constants that are largely attributed to loss of translational entropy at the interface. Finally, the fusogenicity of the various coiled-coil motifs was explored, and the results provide clear evidence that hemifusion followed by full fusion requires a parallel orientation of α-helices, whereas antiparallel oriented coiled-coil motifs display only docking. PMID:23283228

  1. Structural characteristics of the redox-sensing coiled coil in the voltage-gated H+ channel.

    Science.gov (United States)

    Fujiwara, Yuichiro; Takeshita, Kohei; Nakagawa, Atsushi; Okamura, Yasushi

    2013-06-21

    Oxidation is an important biochemical defense mechanism, but it also elicits toxicity; therefore, oxidation must be under strict control. In phagocytotic events in neutrophils, the voltage-gated H(+) (Hv) channel is a key regulator of the production of reactive oxygen species against invading bacteria. The cytoplasmic domain of the Hv channel forms a dimeric coiled coil underpinning a dimerized functional unit. Importantly, in the alignment of the coiled-coil core, a conserved cysteine residue forms a potential intersubunit disulfide bond. In this study, we solved the crystal structures of the coiled-coil domain in reduced, oxidized, and mutated (Cys → Ser) states. The crystal structures indicate that a pair of Cys residues forms an intersubunit disulfide bond dependent on the redox conditions. CD spectroscopy revealed that the disulfide bond increases the thermal stability of the coiled-coil protein. We also reveal that two thiol modifier molecules are able to bind to Cys in a redox-dependent manner without disruption of the dimeric coiled-coil assembly. Thus, the biochemical properties of the cytoplasmic coiled-coil domain in the Hv channel depend on the redox condition, which may play a role in redox sensing in the phagosome.

  2. Multicoil2: predicting coiled coils and their oligomerization states from sequence in the twilight zone.

    Directory of Open Access Journals (Sweden)

    Jason Trigg

    Full Text Available The alpha-helical coiled coil can adopt a variety of topologies, among the most common of which are parallel and antiparallel dimers and trimers. We present Multicoil2, an algorithm that predicts both the location and oligomerization state (two versus three helices of coiled coils in protein sequences. Multicoil2 combines the pairwise correlations of the previous Multicoil method with the flexibility of Hidden Markov Models (HMMs in a Markov Random Field (MRF. The resulting algorithm integrates sequence features, including pairwise interactions, through multinomial logistic regression to devise an optimized scoring function for distinguishing dimer, trimer and non-coiled-coil oligomerization states; this scoring function is used to produce Markov Random Field potentials that incorporate pairwise correlations localized in sequence. Multicoil2 significantly improves both coiled-coil detection and dimer versus trimer state prediction over the original Multicoil algorithm retrained on a newly-constructed database of coiled-coil sequences. The new database, comprised of 2,105 sequences containing 124,088 residues, includes reliable structural annotations based on experimental data in the literature. Notably, the enhanced performance of Multicoil2 is evident when tested in stringent leave-family-out cross-validation on the new database, reflecting expected performance on challenging new prediction targets that have minimal sequence similarity to known coiled-coil families. The Multicoil2 program and training database are available for download from http://multicoil2.csail.mit.edu.

  3. Progress on large superconducting toroidal field coils

    International Nuclear Information System (INIS)

    Haubenreich, P.N.; Luton, J.N.; Thompson, P.B.; Beard, D.S.

    1979-01-01

    Large superconducting toroidal field coils of competing designs are being produced by six major industrial teams. In the US, teams headed by General Dynamics Convair, General Electric, and Westinghouse are under contract to design and fabricate one coil each to specifications established by the Large Coil Program. A facility for testing 6 coils in a toroidal array at fields to 8 to 12 tesla is under construction at Oak Ridge. Through an international agreement, EURATOM, Japan, and Switzerland will produce one coil each for testing with the US coils. Each test coil will have a 2.5 x 3.5 m D-shape winding bore and is designed to operate at a current of 10 to 18 kA at a peak field of 8T while subjected to pulsed fields of 0.14 T applied in 1.0 s. There are significant differences among the six coil designs: five use NbTi, one Nb 3 Sn; three are cooled by pool boiling helium, three by forced flow; five have welded or bolted stainless steel coil cases, one has aluminum plate structure. All are designed to be cryostable at 8T, with structural margin for extended operation. The three US coil teams are almost or completely finished with detailed design and are now procuring materials and setting up manufacturing equipment. The non-US teams are at various stages of verification testing and design. The GDC and GE coils are scheduled for delivery in the spring of 1981 and the others will be completed a year later. The 11-m diameter vessel at the test facility has been completed and major components of the test stand are being procured. Engineering and procurement to upgrade the helium liquifier-refrigerator system are under way

  4. Outcomes with single-coil versus dual-coil implantable cardioverter defibrillators: a meta-analysis.

    Science.gov (United States)

    Sunderland, Nicholas; Kaura, Amit; Murgatroyd, Francis; Dhillon, Para; Scott, Paul A

    2018-03-01

    Dual-coil implantable cardioverter defibrillator (ICD) leads have traditionally been used over single-coil leads due to concerns regarding high defibrillation thresholds (DFT) and consequent poor shock efficacy. However, accumulating evidence suggests that this position may be unfounded and that dual-coil leads may also be associated with higher complication rates during lead extraction. This meta-analysis collates data comparing dual- and single-coil ICD leads. Electronic databases were systematically searched for randomized controlled trials (RCT) and non-randomized studies comparing single-coil and dual-coil leads. The mean differences in DFT and summary estimates of the odds-ratio (OR) for first-shock efficacy and the hazard-ratio (HR) for all-cause mortality were calculated using random effects models. Eighteen studies including a total of 138,124 patients were identified. Dual-coil leads were associated with a lower DFT compared to single coil leads (mean difference -0.83J; 95% confidence interval [CI] -1.39--0.27; P = 0.004). There was no difference in the first-shock success rate with dual-coil compared to single-coil leads (OR 0.74; 95%CI 0.45-1.21; P=0.22). There was a significantly lower risk of all-cause mortality associated with single-coil leads (HR 0.91; 95%CI 0.86-0.95; P dual-coil leads. The mortality benefit with single-coil leads most likely represents patient selection bias. Given the increased risk and complexity of extracting dual-coil leads, centres should strongly consider single-coil ICD leads as the lead of choice for routine new left-sided ICD implants. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  5. HydroCoil as an adjuvant to bare platinum coil treatment of 100 cerebral aneurysms

    International Nuclear Information System (INIS)

    Fanning, Noel F.; Berentei, Zsolt; Brennan, Paul R.; Thornton, John

    2007-01-01

    Introduction The overall safety of the HydroCoil, an expansile hybrid hydrogel-platinum coil, is unknown. We report a prospective observational study of our first 100 cerebral aneurysms treated with HydroCoils, focusing on safety and initial efficacy.Methods Indications, procedural complications, clinical and angiographic outcomes were recorded. Packing density, number of coils deployed and angiographic results were compared with those in a matched control group of 100 aneurysms treated solely with bare platinum coils. HydroCoil complication rates were compared to bare platinum coil rates at our institution and in published series. Results Adjuvant HydroCoil treatment led to increased mean percentage aneurysm filling compared to controls (50 ± 21% versus 27 ± 13%, P < 0.001). Immediate posttreatment angiographic results showed significantly (P < 0.001) more complete occlusions and fewer incomplete (<95%) occlusions compared to controls. Intermediate follow-up angiograms (median 7.5 months) in 63 aneurysms showed a trend towards fewer incomplete occlusions with HydroCoil treatment. There were significantly fewer major recurrences with HydroCoil treatment compared to the control treatment (9.5% versus 22.6%, P 0.046). In the adjuvant HydroCoil group, major recurrent aneurysms had significantly less percentage volume packing with HydroCoils than non-recurrent aneurysms (50.3 ± 5.0% versus 65.3 ± 18.0%, P = 0.04). There was a 12% procedural complication rate, 6% procedural morbidity and 1% mortality rate, similar to institutional and reported bare platinum coil complication rates.Conclusion HydroCoils can be safely deployed with a similar complication rate to bare platinum coils. They result in improved aneurysm filling. Intermediate follow-up angiography showed significantly fewer major recurrences. Long-term follow-up is required to confirm initial improved stability. (orig.)

  6. Designed Coiled-Coil Peptides Inhibit the Type Three Secretion System of Enteropathogenic Escherichia coli

    Science.gov (United States)

    Larzábal, Mariano; Mercado, Elsa C.; Vilte, Daniel A.; Salazar-González, Hector; Cataldi, Angel; Navarro-Garcia, Fernando

    2010-01-01

    Background Enteropathogenic E. coli (EPEC) and enterohemorrhagic E. coli (EHEC) are two categories of E. coli strains associated with human disease. A major virulence factor of both pathotypes is the expression of a type three secretion system (TTSS), responsible for their ability to adhere to gut mucosa causing a characteristic attaching and effacing lesion (A/E). The TTSS translocates effector proteins directly into the host cell that subvert mammalian cell biochemistry. Methods/Principal Findings We examined synthetic peptides designed to inhibit the TTSS. CoilA and CoilB peptides, both representing coiled-coil regions of the translocator protein EspA, and CoilD peptide, corresponding to a coiled–coil region of the needle protein EscF, were effective in inhibiting the TTSS dependent hemolysis of red blood cells by the EPEC E2348/69 strain. CoilA and CoilB peptides also reduced the formation of actin pedestals by the same strain in HEp-2 cells and impaired the TTSS-mediated protein translocation into the epithelial cell. Interestingly, CoilA and CoilB were able to block EspA assembly, destabilizing the TTSS and thereby Tir translocation. This blockage of EspA polymerization by CoilA or CoilB peptides, also inhibited the correct delivery of EspB and EspD as detected by immunoblotting. Interestingly, electron microscopy of bacteria incubated with the CoilA peptide showed a reduction of the length of EspA filaments. Conclusions Our data indicate that coiled-coil peptides can prevent the assembly and thus the functionality of the TTSS apparatus and suggest that these peptides could provide an attractive tool to block EPEC and EHEC pathogenesis. PMID:20140230

  7. Mediterranean detachment zones : thermicity vs heritage.

    Science.gov (United States)

    Labrousse, Loic; Huet, Benjamin; Le Pourhiet, Laetitia; Jolivet, Laurent; Burov, Evgenii

    2017-04-01

    Even if the seminal comprehensive descriptions of Metamorphic Core Complexes (MCCs) in the American Cordillera mentionned lower plates constituted of gneiss and intruded by granites (e. g. Snake Range, Whipple Mountains), the actual definition of MCCs : « Cordilleran metamorphic core complexes appear to be bodies from the middle crust that have been dragged out from beneath fracturing and extending upper crustal rocks, and exposed beneath shallow-dipping (normal slip) faults of large areal extent » {as in Lister & Davis, 1989, Journal of Structural Geology, v. 11, pp. 65-94} refers to rocks exhumed from the middle crust whatever their thermal history. The fundamental property of this middle crust resides in its ability fo flow lateraly toward the forming dome, to accommodate stretching of the upper plate and preserve a relatively flat moho. Even though thermal reequilibration can induce weakening of the lower crust, a similar strength profile can also be inherited from pre-extension evolution of the continental crust and promote development of the original structure of MCCs : their detachment. In order to unravel the rheological meaning of detachments, we propose here a review of extensional shear zones described as detachments in the Mediterranean realm, and establish a three end-members typology with « hot MCCs » as one end-member, and two cold MCC end-members with a weak middle crust due to stacking of high pressure metapelitic nappes or a strong upper crust responsible for the strength contrast exaggeration between the upper and lower crust. New fully coupled thermo-mechanical modeling experiments together with a review of comparable published results allow to test this three end-member typology and determine the critical strength constrast for the perennial development of a detachment zone. A 1000 ratio between the strength at the brittle-ductile transition and the strength at the base of the crust seems a boundary value between localized extensional modes

  8. Coil Optimization for High Temperature Superconductor Machines

    DEFF Research Database (Denmark)

    Mijatovic, Nenad; Jensen, Bogi Bech; Abrahamsen, Asger Bech

    2011-01-01

    This paper presents topology optimization of HTS racetrack coils for large HTS synchronous machines. The topology optimization is used to acquire optimal coil designs for the excitation system of 3 T HTS machines. Several tapes are evaluated and the optimization results are discussed...

  9. Evidence-based pathology: umbilical cord coiling.

    Science.gov (United States)

    Khong, T Y

    2010-12-01

    The generation of a pathology test result must be based on criteria that are proven to be acceptably reproducible and clinically relevant to be evidence-based. This review de-constructs the umbilical cord coiling index to illustrate how it can stray from being evidence-based. Publications related to umbilical cord coiling were retrieved and analysed with regard to how the umbilical coiling index was calculated, abnormal coiling was defined and reference ranges were constructed. Errors and other influences that can occur with the measurement of the length of the umbilical cord or of the number of coils can compromise the generation of the coiling index. Definitions of abnormal coiling are not consistent in the literature. Reference ranges defining hypocoiling or hypercoiling have not taken those potential errors or the possible effect of gestational age into account. Even the way numerical test results in anatomical pathology are generated, as illustrated by the umbilical coiling index, warrants a critical analysis into its evidence base to ensure that they are reproducible or free from errors.

  10. Operator coil monitoring Acceptance Test Procedure

    International Nuclear Information System (INIS)

    Erhart, M.F.

    1995-01-01

    The readiness of the Data Acquisition and Control System (DACS) to provide monitoring and control of the Programmable Logic Controller (PLC) abort coils from the Master and RSS stations will be systematically tested during performance of this procedure. It should be noted that these are not physical abort coils but software coils controlled by the software's ladder logic. The readiness of the DACS to properly interface with the ENRAF wire level gauge installed in the SY-101 storage tank will also be tested. During this test, a verification of all abort coil indications will be conducted at the DACS Development Facility in the 306E Building by injecting an input signal for each DACS sensor that has an associated abort coil until the abort coil actuates, and then ensuring that the status of the abort coil indicated at the Master and RSS stations is correct. Each abort coil will also be tested to ensure that the ''ENABLE'' and ''DISABLE'' controls from the Master and RSS stations function correctly, and only with the use of proper passwords

  11. Magnetic Fields at the Center of Coils

    Science.gov (United States)

    Binder, Philippe; Hui, Kaleonui; Goldman, Jesse

    2014-01-01

    In this note we synthesize and extend expressions for the magnetic field at the center of very short and very long current-carrying coils. Elementary physics textbooks present the following equation for the magnetic field inside a very long current-carrying coil (solenoid): B[subscript sol] = µ[subscript 0] (N/L) I, (1) where I is the current, N…

  12. Toroidal field coils for the PDX machine

    International Nuclear Information System (INIS)

    Bushnell, C.W.

    1975-01-01

    This paper describes the engineering design features of the TF coils for the PDX machine. Included are design details of the electrical insulation, water cooling, and coil segment joint which allows access to the central machine area. A discussion of the problems anticipated in the manufacture and the planned solutions are presented

  13. Optimization of modular coils for stellarator fields

    International Nuclear Information System (INIS)

    Chu, T.K.; Furth, H.P.; Johnson, J.L.; Ludescher, C.; Weimer, K.E.

    1982-02-01

    Introduction of a non-sinusoidal deformation can enhance the efficacy of modular coils for generating magnetic fields with a built-in rotational transform. Techniques are developed that provide an understanding of how specific deformations affect the harmonic content of the magnetic field and thus the properties of the vacuum configuration. This provides an optimization procedure for coil design

  14. The bar coil for NMR tomograph

    International Nuclear Information System (INIS)

    Bogorodzki, P.; Piatkowski, A.; Wasielewski, J.

    1995-01-01

    The bar coil (bi-planar) for the NMR tomograph, designed for medical diagnostics, has been described. The tests of coil shown that it generates good homogenous magnetic field in a big volume what results in improving of the signal-to-noise ratio

  15. Functional investigation of the plant-specific long coiled-coil proteins PAMP-INDUCED COILED-COIL (PICC and PICC-LIKE (PICL in Arabidopsis thaliana.

    Directory of Open Access Journals (Sweden)

    Sowmya Venkatakrishnan

    Full Text Available We have identified and characterized two Arabidopsis long coiled-coil proteins PAMP-INDUCED COILED-COIL (PICC and PICC-LIKE (PICL. PICC (147 kDa and PICL (87 kDa are paralogs that consist predominantly of a long coiled-coil domain (expanded in PICC, with a predicted transmembrane domain at the immediate C-terminus. Orthologs of PICC and PICL were found exclusively in vascular plants. PICC and PICL GFP fusion proteins are anchored to the cytoplasmic surface of the endoplasmic reticulum (ER membrane by a C-terminal transmembrane domain and a short tail domain, via a tail-anchoring mechanism. T-DNA-insertion mutants of PICC and PICL as well as the double mutant show an increased sensitivity to the plant abiotic stress hormone abscisic acid (ABA in a post-germination growth response. PICC, but not PICL gene expression is induced by the bacterial pathogen-associated molecular pattern (PAMP flg22. T-DNA insertion alleles of PICC, but not PICL, show increased susceptibility to the non-virulent strain P. syringae pv. tomato DC3000 hrcC, but not to the virulent strain P. syringae pv. tomato DC3000. This suggests that PICC mutants are compromised in PAMP-triggered immunity (PTI. The data presented here provide first evidence for the involvement of a plant long coiled-coil protein in a plant defense response.

  16. Functional investigation of the plant-specific long coiled-coil proteins PAMP-INDUCED COILED-COIL (PICC) and PICC-LIKE (PICL) in Arabidopsis thaliana.

    Science.gov (United States)

    Venkatakrishnan, Sowmya; Mackey, David; Meier, Iris

    2013-01-01

    We have identified and characterized two Arabidopsis long coiled-coil proteins PAMP-INDUCED COILED-COIL (PICC) and PICC-LIKE (PICL). PICC (147 kDa) and PICL (87 kDa) are paralogs that consist predominantly of a long coiled-coil domain (expanded in PICC), with a predicted transmembrane domain at the immediate C-terminus. Orthologs of PICC and PICL were found exclusively in vascular plants. PICC and PICL GFP fusion proteins are anchored to the cytoplasmic surface of the endoplasmic reticulum (ER) membrane by a C-terminal transmembrane domain and a short tail domain, via a tail-anchoring mechanism. T-DNA-insertion mutants of PICC and PICL as well as the double mutant show an increased sensitivity to the plant abiotic stress hormone abscisic acid (ABA) in a post-germination growth response. PICC, but not PICL gene expression is induced by the bacterial pathogen-associated molecular pattern (PAMP) flg22. T-DNA insertion alleles of PICC, but not PICL, show increased susceptibility to the non-virulent strain P. syringae pv. tomato DC3000 hrcC, but not to the virulent strain P. syringae pv. tomato DC3000. This suggests that PICC mutants are compromised in PAMP-triggered immunity (PTI). The data presented here provide first evidence for the involvement of a plant long coiled-coil protein in a plant defense response.

  17. Functional Investigation of the Plant-Specific Long Coiled-Coil Proteins PAMP-INDUCED COILED-COIL (PICC) and PICC-LIKE (PICL) in Arabidopsis thaliana

    Science.gov (United States)

    Venkatakrishnan, Sowmya; Mackey, David; Meier, Iris

    2013-01-01

    We have identified and characterized two Arabidopsis long coiled-coil proteins PAMP-INDUCED COILED-COIL (PICC) and PICC-LIKE (PICL). PICC (147 kDa) and PICL (87 kDa) are paralogs that consist predominantly of a long coiled-coil domain (expanded in PICC), with a predicted transmembrane domain at the immediate C-terminus. Orthologs of PICC and PICL were found exclusively in vascular plants. PICC and PICL GFP fusion proteins are anchored to the cytoplasmic surface of the endoplasmic reticulum (ER) membrane by a C-terminal transmembrane domain and a short tail domain, via a tail-anchoring mechanism. T-DNA-insertion mutants of PICC and PICL as well as the double mutant show an increased sensitivity to the plant abiotic stress hormone abscisic acid (ABA) in a post-germination growth response. PICC, but not PICL gene expression is induced by the bacterial pathogen-associated molecular pattern (PAMP) flg22. T-DNA insertion alleles of PICC, but not PICL, show increased susceptibility to the non-virulent strain P. syringae pv. tomato DC3000 hrcC, but not to the virulent strain P. syringae pv. tomato DC3000. This suggests that PICC mutants are compromised in PAMP-triggered immunity (PTI). The data presented here provide first evidence for the involvement of a plant long coiled-coil protein in a plant defense response. PMID:23451199

  18. Composite coils for toroidal field coils and method of using same

    International Nuclear Information System (INIS)

    Perkins, R. G.; Trujillo, S. M.

    1985-01-01

    A composite toroidal field (TF) generating means consisting of segmented magnetic coil windings is disclosed. Each coil winding of the TF generating means consists of a copper or copper alloy conductor segment and an aluminum or aluminum alloy conductor segment. The conductor segments are joined at a high strength, low electrical resistance joint and the joint may either be a mechanical or metallurgical one. The use of the aluminum or aluminum alloy conductor segments improves the neutron economy of the reactor with which the TF coil is associated and reduces TF coil nuclear heating and heating gradients, and activation in the TF coils

  19. Kinematic evidence for downdip movement on the Mormon Peak detachment

    Science.gov (United States)

    Walker, Christopher D.; Anders, Mark H.; Christie-Blick, Nicholas

    2007-03-01

    The Mormon Peak detachment is considered to be one of the best examples of a rooted upper crustal detachment fault that propagated through the brittle crust at a low angle. The hanging wall of the detachment today consists of a number of isolated blocks that have been interpreted as remnants of a once-contiguous extensional allochthon. Here we present the results of a new study of directional indicators from the basal surfaces beneath these blocks. These measurements do not agree with the long-standing interpretation of a S75°W movement direction for the detachment hanging wall. Instead, the most recent movement on each section of the detachment took place approximately parallel to the present downdip direction. We conclude that the Mormon Peak detachment is best explained as the basal surfaces to a series of rootless gravity slides.

  20. Fibrinogen and rhegmatogenous retinal detachment: a pilot prospective study

    Directory of Open Access Journals (Sweden)

    IP Theocharis

    2010-02-01

    Full Text Available IP TheocharisOphthalmology Department, Iaso General Hospital, Athens, GreecePurpose: To examine the correlation, if any, between fibrinogen plasma levels (FPL and the clinical features of rhegmatogenous retinal detachment (RRD.Methods: FPL were measured preoperatively in 33 patients with primary RRD. Patient characteristics and detachment features such as the numbers of breaks and the extent of the detachment were recorded;Results: No statistically significant correlation was found between FPL and the number of breaks. A statistically significant correlation was found between FPL and the extent of the RRD, even if the influence of the number of breaks was excluded. Conclusions: FPL correlate with retinal detachment extent, which implicates an acute inflammatory response to detachment traumatic phenomenon or a role of the fibrinogen molecule in retinal adhesiveness.Keywords: fibrinogen, retinal detachment, pathogenesis

  1. Structural recovery of the detached macula after retinal detachment repair as assessed by optical coherence tomography.

    Science.gov (United States)

    Joe, Soo Geun; Kim, Yoon Jeon; Chae, Ju Byung; Yang, Sung Jae; Lee, Joo Yong; Kim, June-Gone; Yoon, Young Hee

    2013-06-01

    To investigate correlations between preoperative and postoperative foveal microstructures in patients with macula-off rhegmatogenous retinal detachment (RRD). We reviewed the records of 31 eyes from 31 patients with macula-off RRD who had undergone successful re-attachment surgery. We analyzed data obtained from complete ophthalmologic examinations and optical coherence tomography (OCT) before and 9 to 12 months after surgery. All postoperative OCT measurements were taken with spectral-domain OCT, but a subset of preoperative OCT measurements were taken with time-domain OCT. The mean duration of macular detachment was 15.5 ± 15.2 days, and mean preoperative best-corrected visual acuity (BCVA, logarithm of the minimum angle of resolution) was 1.03 ± 0.68. Preoperative visual acuity was correlated with retinal detachment height (p macula-off duration. The final BCVA was significantly correlated with integrity of the junction between the photoreceptor inner and outer segments (IS/OS) combined with the continuity of external limiting membrane (ELM) (p = 0.025). The presence of IRS and OLU on a detached macula were highly correlated with the final postoperative integrity of the IS/OS junction and the ELM (p = 0.017). Eyes preoperatively exhibiting IRS and OLU showed a higher incidence of disruption to the photoreceptor IS/OS junction and the ELM at final follow-up. Such a close correlation between preoperative and postoperative structural changes may explain why ultimate visual recovery in such eyes is poor.

  2. Startup of Large Coil Test Facility

    International Nuclear Information System (INIS)

    Haubenreich, P.N.; Bohanan, R.E.; Fietz, W.A.; Luton, J.N.; May, J.R.

    1984-01-01

    The Large Coil Test Facility (LCTF) is being used to test superconducting toroidal field coils about one-third the size of those for INTOR. Eventually, six different coils from four countries will be tested. Operations began in 1983 with acceptance testing of the helium refrigerator/liquefier system. Comprehensive shakedown of the facility and tests with the first three coils (from Japan, the United States, and Switzerland) were successfully accomplished in the summer of 1984. Currents up to 10,200 A and fields up to 6.4 T were reached. Data were obtained on performance of refrigerator, helium distribution, power supplies, controls, and data acquisition systems and on the acoustic emission, voltages, currents, and mechanical strains during charging and discharging the coils

  3. Design description of the Large Coil Test Facility pulse-coil support and transport system

    International Nuclear Information System (INIS)

    Queen, C.C.

    1981-01-01

    In order to simulate the transient fields which would be imposed on superconducting toroidal field coils in an operating tokamak reactor, the Large Coil Test Facility (LCTF) test stand includes a set of pulse coils. This set of pulse coils is designed to be moved from one test location to another within the LCTF vacuum vessel while the vessel is operating under vacuum and the test stand and test coils are at an operating temperature of 4.2K. This operating environment and the extremely high magnetic loads have necessitated some unique design features for the pulse coil support and transport system. The support structure for the pulse coil must react high overturning moments and axial loads induced on the pulse coil by the interaction of the pulse field with the field generated by the large test coils. These loads are reacted into the test stand support structure or spider frame by an arrangement of six pedestals and a support beam. In order to move the pulse coil set from one test location to another, the support beam containing the pulse coils must be driven across rollers mounted on the pedestals, then clamped securely to react the loads. Because these operations must be performed in a vacuum environment at cryogenic tmperature, special consideration was given to component design

  4. Detection of detachments and inhomogeneities in frescos by Compton scattering

    International Nuclear Information System (INIS)

    Castellano, A.; Cesareo, R.; Buccolieri, G.; Donativi, M.; Palama, F.; Quarta, S.; De Nunzio, G.; Brunetti, A.; Marabelli, M.; Santamaria, U.

    2005-01-01

    A mobile instrument has been developed for the detection and mapping of detachments in frescos by using Compton back scattered photons. The instrument is mainly composed of a high energy X-ray tube, an X-ray detection system and a translation table. The instrument was first applied to samples simulating various detachment situations, and then transferred to the Vatican Museum to detect detachments and inhomogeneities in the stanza di Eliodoro, one of the 'Raphael's stanze'

  5. Detection of detachments and inhomogeneities in frescos by Compton scattering

    Energy Technology Data Exchange (ETDEWEB)

    Castellano, A. [Dipartimento di Scienza dei Materiali, Universita di Lecce, 73100 Lecce (Italy); INFN, Sezione di Lecce, via per Arnesano, 73100 Lecce (Italy); Cesareo, R. [Istituto di Matematica e Fisica, Universita di Sassari, 07100 Sassari (Italy) and INFN, Sezione di Cagliari, Cittadella Universitaria di Monserrato, 09042 Cagliari (Italy)]. E-mail: cesareo@uniss.it; Buccolieri, G. [Dipartimento di Scienza dei Materiali, Universita di Lecce, 73100 Lecce (Italy); INFN, Sezione di Lecce, via per Arnesano, 73100 Lecce (Italy); Donativi, M. [Dipartimento di Scienza dei Materiali, Universita di Lecce, 73100 Lecce (Italy); Palama, F. [Dipartimento di Scienza dei Materiali, Universita di Lecce, 73100 Lecce (Italy); INFN, Sezione di Lecce, via per Arnesano, 73100 Lecce (Italy); Quarta, S. [Dipartimento di Scienza dei Materiali, Universita di Lecce, 73100 Lecce (Italy); INFN, Sezione di Lecce, via per Arnesano, 73100 Lecce (Italy); De Nunzio, G. [Dipartimento di Scienza dei Materiali, Universita di Lecce, 73100 Lecce (Italy); INFN, Sezione di Lecce, via per Arnesano, 73100 Lecce (Italy); Brunetti, A. [Istituto di Matematica e Fisica, Universita di Sassari, 07100 Sassari (Italy); INFN, Sezione di Cagliari, Cittadella Universitaria di Monserrato, 09042 Cagliari (Italy); Marabelli, M. [Istituto Centrale del Restauro, P.zza S. Francesco di Paola, 00184 Rome (Italy); Santamaria, U. [Laboratori dei Musei Vaticani, Citta del Vaticano, Rome (Italy)

    2005-07-01

    A mobile instrument has been developed for the detection and mapping of detachments in frescos by using Compton back scattered photons. The instrument is mainly composed of a high energy X-ray tube, an X-ray detection system and a translation table. The instrument was first applied to samples simulating various detachment situations, and then transferred to the Vatican Museum to detect detachments and inhomogeneities in the stanza di Eliodoro, one of the 'Raphael's stanze'.

  6. Meniscus Shapes in Detached Bridgman Growth

    Science.gov (United States)

    Volz, M. P.; Mazuruk, K

    2010-01-01

    In detached Bridgman crystal growth, most of the melt is in contact with the ampoule wall, but the crystal is separated from the wall by a small gap, typically 1-100 micrometers. A liquid free surface, or meniscus, bridges across this gap at the position of the melt-crystal interface. Meniscus shapes have been calculated for the case of detached Bridgman growth in cylindrical ampoules by solving the Young-Laplace equation. Key parameters affecting meniscus shapes are the growth angle, contact angle of the meniscus to the ampoule wall, the pressure differential across the meniscus, and the Bond number, a measure of the ratio of gravitational to capillary forces. In general, for specified values of growth and contact angles, solutions exist only over a finite range of pressure differentials. For intermediate values of the Bond number, there are multiple solutions to the Young-Laplace equations. There are also cases where, as a function of pressure differential, existence intervals alternate with intervals where no solutions exist. The implications of the meniscus shape calculations on meniscus stability are discussed.

  7. Extent of Detached Retina and Lens Status Influence Intravitreal Protein Expression in Rhegmatogenous Retinal Detachment.

    Science.gov (United States)

    Pollreisz, Andreas; Sacu, Stefan; Eibenberger, Katharina; Funk, Marion; Kivaranovic, Danijel; Zlabinger, Gerhard J; Georgopoulos, Michael; Schmidt-Erfurth, Ursula

    2015-08-01

    The aim of the study was to compare intravitreal cytokines and chemokines to clinical parameters in patients with rhegmatogenous retinal detachment (RRD). In this prospective study vitreous samples were taken undiluted from 60 patients with RRD and 20 age-matched controls with idiopathic epiretinal membranes at the beginning of primary vitrectomy. The following clinical parameters were assessed from RRD patients prior to surgery: number of quadrants detached, RD height, lens status, symptom duration, and refractive power. Concentrations of 40 different proteins in the vitreous of RRD eyes were measured by multiplex protein array, compared with controls and correlated to clinical parameters. Ten cytokines and chemokines were significantly upregulated in the vitreous of RRD eyes compared with controls (tissue inhibitors of metalloproteinases [TIMP]-1 and -2, macrophage inflammatory protein [MIP]-1α, monocyte chemoattractant protein [MCP]-1, IL-6, and -8, inducible protein (IP)-10, brain-derived neurotrophic factor [BDNF], TGFβ-3, and platelet-derived growth factor [PDGF]-AB/BB). Linear regression analysis revealed that IL-8 and TGFβ-3 increased with the number of retinal quadrants detached, while TIMP-1 rose in eyes with greater RD heights. Concentrations of IP-10 and myeloperoxidase (MPO) peaked in eyes with two or more quadrants detached, while TIMP-2 was highest expressed in the vitreous of eyes with great RD height. In pseudophakic eyes with higher detachment height levels of vascular cell adhesion molecule (VCAM)-1 were significantly increased, while neural cell adhesion molecule (NCAM) was decreased in pseudophakic patients with shallow RD height. Extent of RRD and lens status significantly influence intravitreal proinflammatory, profibrotic, and proapoptotic protein expression. These data contribute to the fundamental understanding of pathophysiological mechanisms in RRD and may serve as a basis for development of adjunct therapeutics to facilitate

  8. Risk of retinal detachment in patients with lattice degeneration.

    Science.gov (United States)

    Sasaki, K; Ideta, H; Yonemoto, J; Tanaka, S; Hirose, A; Oka, C

    1998-01-01

    To determine the risk of retinal detachment in patients with lattice degeneration of the retina, we statistically analyzed the incidence of retinal detachment in these patients. The data of hospital patients with retinal detachment associated with lattice degeneration in Kumamoto Prefecture, Japan, in 1990 were collected. The prevalence of lattice degeneration in Kumamoto was reported to be 9.5% in 1980. Based on population data from the 1990 census, the cumulative incidence of retinal detachment associated with lattice degeneration was calculated in this study. Among 1,840,000 residents in Kumamoto, there were 110 patients with retinal detachment associated with lattice degeneration; 72 with detachment resulting from tractional tears (tears), and 38 with detachment from atrophic holes. The cumulative incidence of retinal detachment from atrophic holes was 1.5% at the age of 40 years; from tears it was 3.6% at the age of 80 years. The cumulative incidence of detachment from both atrophic holes and tears was 5.3% at the age of 80 years. The results of this study are useful for clarifying the natural course of lattice degeneration.

  9. Magnetic resonance imaging in ophthalmic diagnosis. Results of examinations using a small field-of-view surface coil

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Yuji; Yoshida, Akitoshi; Kanno, Harumi; Ogasawara, Hironobu; Murakami, Noboru [Asahikawa Medical College, Hokkaido (Japan); Cheng, Hong-Ming

    1997-01-01

    We obtained T{sub 1}-and T{sub 2}-weighted magnetic resonance (MR) images in 3 patients with vitreoretinal disorders using a recently developed surface coil that was inductively coupled and had a small field of view. On both T{sub 1}-and T{sub 2}-weighted images, tractional retinal detachment was clearly detected in the first patient, who had proliferative diabetic retinopathy. T{sub 1}- and T{sub 2}-weighted images of the second patient, who had total retinal detachment with proliferative vitreous retinopathy, revealed a funnel-shaped thickened retina. The third patient had postoperative rhegmatogenous retinal detachment with opacity due to postoperative cataract and intravitreous injection of gas; on this patient`s MR images we could clearly differentiate the reattached retina, silicone used for scleral buckling, and intravitreous gas, even though these differentiations were not possible with ophthalmoscopy or B-scan ultrasonography. High resolution MR imaging with our technique can be performed in a short time and regardless of the eye`s condition. Our findings strongly indicate that MRI with a small field-of-view surface coil is a useful tool for diagnosing various vitreoretinal disorders and observing pathological changes. (author)

  10. Simultaneous formation of right- and left-handed anti-parallel coiled-coil interfaces by a coil2 fragment of human lamin A.

    Science.gov (United States)

    Kapinos, Larisa E; Burkhard, Peter; Herrmann, Harald; Aebi, Ueli; Strelkov, Sergei V

    2011-04-22

    The elementary building block of all intermediate filaments (IFs) is a dimer featuring a central α-helical rod domain flanked by the N- and C-terminal end domains. In nuclear IF proteins (lamins), the rod domain consists of two coiled-coil segments, coil1 and coil2, that are connected by a short non-helical linker. Coil1 and the C-terminal part of coil2 contain the two highly conserved IF consensus motifs involved in the longitudinal assembly of dimers. The previously solved crystal structure of a lamin A fragment (residues 305-387) corresponding to the second half of coil2 has yielded a parallel left-handed coiled coil. Here, we present the crystal structure and solution properties of another human lamin A fragment (residues 328-398), which is largely overlapping with fragment 305-387 but harbors a short segment of the tail domain. Unexpectedly, no parallel coiled coil forms within the crystal. Instead, the α-helices are arranged such that two anti-parallel coiled-coil interfaces are formed. The most significant interface has a right-handed geometry, which is accounted for by a characteristic 15-residue repeat pattern that overlays with the canonical heptad repeat pattern. The second interface is a left-handed anti-parallel coiled coil based on the predicted heptad repeat pattern. In solution, the fragment reveals only a weak dimerization propensity. We speculate that the C-terminus of coil2 might unzip, thereby allowing for a right-handed coiled-coil interface to form between two laterally aligned dimers. Such an interface might co-exist with a heterotetrameric left-handed coiled-coil assembly, which is expected to be responsible for the longitudinal A(CN) contact. Copyright © 2011. Published by Elsevier Ltd.

  11. N@a and N@d: Oligomer and Partner Specification by Asparagine in Coiled-Coil Interfaces.

    Science.gov (United States)

    Fletcher, Jordan M; Bartlett, Gail J; Boyle, Aimee L; Danon, Jonathan J; Rush, Laura E; Lupas, Andrei N; Woolfson, Derek N

    2017-02-17

    The α-helical coiled coil is one of the best-studied protein-protein interaction motifs. As a result, sequence-to-structure relationships are available for the prediction of natural coiled-coil sequences and the de novo design of new ones. However, coiled coils adopt a wide range of oligomeric states and topologies, and our understanding of the specification of these and the discrimination between them remains incomplete. Gaps in our knowledge assume more importance as coiled coils are used increasingly to construct biomimetic systems of higher complexity; for this, coiled-coil components need to be robust, orthogonal, and transferable between contexts. Here, we explore how the polar side chain asparagine (Asn, N) is tolerated within otherwise hydrophobic helix-helix interfaces of coiled coils. The long-held view is that Asn placed at certain sites of the coiled-coil sequence repeat selects one oligomer state over others, which is rationalized by the ability of the side chain to make hydrogen bonds, or interactions with chelated ions within the coiled-coil interior of the favored state. We test this with experiments on de novo peptide sequences traditionally considered as directing parallel dimers and trimers, and more widely through bioinformatics analysis of natural coiled-coil sequences and structures. We find that when located centrally, rather than near the termini of such coiled-coil sequences, Asn does exert the anticipated oligomer-specifying influence. However, outside of these bounds, Asn is observed less frequently in the natural sequences, and the synthetic peptides are hyperthermostable and lose oligomer-state specificity. These findings highlight that not all regions of coiled-coil repeat sequences are equivalent, and that care is needed when designing coiled-coil interfaces.

  12. Acceleration of aneurysm healing by P(DLLA-co-TMC)-coated coils enabling the controlled release of vascular endothelial growth factor

    International Nuclear Information System (INIS)

    Wang, Qiujing; Gao, Yuyuan; Sun, Xinlin; Ji, Bin; Cui, Xubo; Liu, Yaqi; Zheng, Tao; Chen, Chengwei; Jiang, Xiaodan; Zhu, Aiping; Quan, Daping

    2014-01-01

    Since the introduction of the detachable coil in endovascular treatment of intracranial aneurysms, the in-hospital mortality rate has been significantly decreased. Recurrence of the aneurysm remains the major drawback of using detachable coils. We prepared a bioactive coil coated with poly(d,l-lactide)-7co-(1,3-trimethylene carbonate) (P(DLLA-co-TMC)), a novel copolymer for controlling the release of vascular endothelial growth factor (VEGF). Platinum coils were prepared by successive coating with cationic P(DLLA-co-TMC) and anionic heparin. Then, recombinant human VEGF-165 (rhVEGF) was immobilized by affinity binding to heparin. The morphological characteristics and sustained in vitro release of rhVEGF were examined using scanning electron microscopy and enzyme-linked immunosorbent assay, respectively. The efficacy of these novel coils modified by P(DLLA-co-TMC)/rhVEGF was tested using a common carotid artery aneurysm model in rats. Experimental aneurysms were embolized with unmodified, P(DLLA-co-TMC)/heparin-coated or P(DLLA-co-TMC)/rhVEGF-coated platinum coils (n = 18). The coils were removed on days 15, 30 and 90 after insertion, and the histological and immunohistochemical analysis of factor VIII was performed to confirm the presence of endothelial cells in the organized area. In addition, the controlled in vivo release of VEGF was confirmed by Western blotting analysis. The release of VEGF tended to increase during the whole period and no burst release was observed. In the group treated with P(DLLA-co-TMC)/rhVEGF-coated platinum coils, clot organization and endothelial cell proliferation were accelerated. The immunohistochemistry study showed that the expression of factor VIII was found in the P(DLLA-co-TMC)/rhVEGF-coated coil group but not in the other two groups. Furthermore, Western blotting analysis confirmed that the major released VEGF in the aneurysm sac was from the P(DLLA-co-TMC)/VEGF-coated coil. P(DLLA-co-TMC)/rhVEGF-coated platinum coils can

  13. Force generation by orthodontic coil springs.

    Science.gov (United States)

    von Fraunhofer, J A; Bonds, P W; Johnson, B E

    1993-01-01

    Nickel titanium (NiTi) coil springs are a new development in orthodontics, designed to produce light continuous forces. This study compares the force delivery by NiTi open and closed coil springs during unloading (de-activation) to that provided by comparable stainless steel (SS) springs. Open-coil springs (0.010 x 0.035 inch) were compressed from their initial length of 15 mm to 6 mm and the forces generated with spring recovery recorded. Closed-coil springs (0.009 x 0.035 inch) were distracted from their initial length of 3 mm to 9 mm and the force recorded as the spring recovered. The closed-coil NiTi springs produced light continuous forces of 75-90 g over the distraction range of 6 mm while the open-coil springs produced forces of 55-70 g within the 9 mm compression range. SS springs produced heavier forces, ca. 200 g, for an activation of 1 mm and the generated force increased rapidly as the activation was increased. The findings indicate that NiTi coil springs deliver optimal forces for orthodontic tooth movement over a longer activation range than comparable SS springs.

  14. Correcting coils in end magnets of accelerators

    Directory of Open Access Journals (Sweden)

    L. R. P. Kassab

    1998-05-01

    Full Text Available We present an empirical investigation of the correcting coils behavior used to homogenize the field distribution of the race-track microtron accelerator end magnets. These end magnets belong to the second stage of the 30.0 MeV cw electron accelerator under construction at IFUSP, the race-track microtron booster, in which the beam energy is raised from 1.97 to 5.1 MeV. The correcting coils are attached to the pole faces and are based on the inhomogeneities of the magnetic field measured. The performance of these coils, when operating the end magnets with currents that differ by ±10% from the one used in the mappings that originated the coils copper leads, is presented. For one of the magnets, adjusting conveniently the current of the correcting coils makes it possible to homogenize field distributions of different intensities, once their shapes are practically identical to those that originated the coils. For the other one, the shapes are changed and the coils are less efficient. This is related to intrinsic factors that determine the inhomogeneities. However, we obtained uniformity of 0.001% in both cases.

  15. Crystal structure of a coiled-coil domain from human ROCK I.

    Directory of Open Access Journals (Sweden)

    Daqi Tu

    2011-03-01

    Full Text Available The small GTPase Rho and one of its targets, Rho-associated kinase (ROCK, participate in a variety of actin-based cellular processes including smooth muscle contraction, cell migration, and stress fiber formation. The ROCK protein consists of an N-terminal kinase domain, a central coiled-coil domain containing a Rho binding site, and a C-terminal pleckstrin homology domain. Here we present the crystal structure of a large section of the central coiled-coil domain of human ROCK I (amino acids 535-700. The structure forms a parallel α-helical coiled-coil dimer that is structurally similar to tropomyosin, an actin filament binding protein. There is an unusual discontinuity in the coiled-coil; three charged residues (E613, R617 and D620 are positioned at what is normally the hydrophobic core of coiled-coil packing. We speculate that this conserved irregularity could function as a hinge that allows ROCK to adopt its autoinhibited conformation.

  16. A set of computationally designed orthogonal antiparallel homodimers that expands the synthetic coiled-coil toolkit.

    Science.gov (United States)

    Negron, Christopher; Keating, Amy E

    2014-11-26

    Molecular engineering of protein assemblies, including the fabrication of nanostructures and synthetic signaling pathways, relies on the availability of modular parts that can be combined to give different structures and functions. Currently, a limited number of well-characterized protein interaction components are available. Coiled-coil interaction modules have been demonstrated to be useful for biomolecular design, and many parallel homodimers and heterodimers are available in the coiled-coil toolkit. In this work, we sought to design a set of orthogonal antiparallel homodimeric coiled coils using a computational approach. There are very few antiparallel homodimers described in the literature, and none have been measured for cross-reactivity. We tested the ability of the distance-dependent statistical potential DFIRE to predict orientation preferences for coiled-coil dimers of known structure. The DFIRE model was then combined with the CLASSY multistate protein design framework to engineer sets of three orthogonal antiparallel homodimeric coiled coils. Experimental measurements confirmed the successful design of three peptides that preferentially formed antiparallel homodimers that, furthermore, did not interact with one additional previously reported antiparallel homodimer. Two designed peptides that formed higher-order structures suggest how future design protocols could be improved. The successful designs represent a significant expansion of the existing protein-interaction toolbox for molecular engineers.

  17. Exploiting Oligo(amido amine) Backbones for the Multivalent Presentation of Coiled-Coil Peptides.

    Science.gov (United States)

    Gerling-Driessen, Ulla I M; Mujkic-Ninnemann, Nina; Ponader, Daniela; Schöne, Daniel; Hartmann, Laura; Koksch, Beate; Gerling-Driessen, U I M; Schöne, D; Koksch, B; Ponader, D; Mujkic-Ninnemann, N; Hartmann, L

    2015-08-10

    The investigation of coiled coil formation for one mono- and two divalent peptide-polymer conjugates is presented. Through the assembly of the full conjugates on solid support, monodisperse sequence-defined conjugates are obtained with defined positions and distances between the peptide side chains along the polymeric backbone. A heteromeric peptide design was chosen, where peptide K is attached to the polymer backbone, and coiled-coil formation is only expected through complexation with the complementary peptide E. Indeed, the monovalent peptide K-polymer conjugate displays rapid coiled-coil formation when mixed with the complementary peptide E sequence. The divalent systems show intramolecular homomeric coiled-coil formation on the polymer backbone despite the peptide design. Interestingly, this intramolecular assembly undergoes a conformational rearrangement by the addition of the complementary peptide E leading to the formation of heteromeric coiled coil-polymer aggregates. The polymer backbone acts as a template bringing the covalently bound peptide strands in close proximity to each other, increasing the local concentration and inducing the otherwise nonfavorable formation of intramolecular helical assemblies.

  18. Routine phasing of coiled-coil protein crystal structures with AMPLE.

    Science.gov (United States)

    Thomas, Jens M H; Keegan, Ronan M; Bibby, Jaclyn; Winn, Martyn D; Mayans, Olga; Rigden, Daniel J

    2015-03-01

    Coiled-coil protein folds are among the most abundant in nature. These folds consist of long wound α-helices and are architecturally simple, but paradoxically their crystallographic structures are notoriously difficult to solve with molecular-replacement techniques. The program AMPLE can solve crystal structures by molecular replacement using ab initio search models in the absence of an existent homologous protein structure. AMPLE has been benchmarked on a large and diverse test set of coiled-coil crystal structures and has been found to solve 80% of all cases. Successes included structures with chain lengths of up to 253 residues and resolutions down to 2.9 Å, considerably extending the limits on size and resolution that are typically tractable by ab initio methodologies. The structures of two macromolecular complexes, one including DNA, were also successfully solved using their coiled-coil components. It is demonstrated that both the ab initio modelling and the use of ensemble search models contribute to the success of AMPLE by comparison with phasing attempts using single structures or ideal polyalanine helices. These successes suggest that molecular replacement with AMPLE should be the method of choice for the crystallo-graphic elucidation of a coiled-coil structure. Furthermore, AMPLE may be able to exploit the presence of a coiled coil in a complex to provide a convenient route for phasing.

  19. Cloning, overexpression, purification and crystallization of the CRN12 coiled-coil domain from Leishmania donovani.

    Science.gov (United States)

    Srivastava, Vijay Kumar; Rana, Ajay Kumar; Sahasrabuddhe, Amogh A; Gupta, C M; Pratap, J V

    2013-05-01

    Leishmania donovani coronin CRN12 is an actin-binding protein which consists of two domains: an N-terminal WD repeat domain and a C-terminal coiled-coil domain. The coiled-coil domain is 53 residues in length. Helix-helix interactions in general and coiled coils in particular are ubiquitous in the structure of proteins and play a significant role in the association among proteins, including supramolecular assemblies and transmembrane receptors that mediate cellular signalling, transport and actin dynamics. The L. donovani coronin CRN12 coiled-coil domain (5.8 kDa) was cloned, overexpressed, purified to homogeneity and the N-terminal 6×His tag was successfully removed by thrombin cleavage. Crystals of recombinant L. donovani coronin CRN12 coiled-coil domain were grown by vapour diffusion using a hanging-drop setup. Diffraction-quality crystals were obtained and data extending to 2.46 Å resolution were collected at 100 K on BM14, ESRF, Grenoble, France. The crystal belonged to the monoclinic space group C2, with unit-cell parameters a = 118.0, b = 50.6, c = 46.0 Å, β = 111.0°. Matthews coefficient (VM) calculations suggested the presence of 4-6 molecules in the asymmetric unit, corresponding to a solvent content of ∼33-55%, and are consistent with self-rotation function calculations.

  20. Inhibition of the 26S proteasome by peptide mimics of the coiled-coil region of its ATPase subunits.

    Science.gov (United States)

    Inobe, Tomonao; Genmei, Reiko

    Regulation of proteasomal degradation is an indispensable tool for biomedical studies. Thus, there is demand for novel proteasome inhibitors. Proteasomal degradation requires formation of coiled-coil structure by the N-terminal region of ATPase subunits of the proteasome cap. Here we show that peptides that mimic the N-terminal coiled-coil region of ATPase subunits interfere with proteasome function. These results suggest that coiled-coil peptides represent promising new proteasome inhibitors and that N-terminal coiled-coil regions of ATPase subunits are targets for proteasome inhibition. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Magnetic field mapper based on rotating coils

    CERN Document Server

    AUTHOR|(CDS)2087244; Arpaia, Pasquale

    This thesis presents a magnetic field mapper based on rotating coils. The requirements, the architecture, the conceptual design, and the prototype for straight magnets were shown. The proposed system is made up of a rotating coil transducer and a train-like system for longitudinal motion and positioning inside magnet bore. The mapper allows a localized measurement of magnetic fields and the variation of the harmonic multipole content in the magnet ends. The proof-of-principle demonstration and the experimental characterization of the rotating-coil transducer specifically conceived for mapping validated the main objective of satisfying the magnetic measurement needs of the next generation of compact accelerators.

  2. CS model coil experimental log book

    International Nuclear Information System (INIS)

    Nishijima, Gen; Sugimoto, Makoto; Nunoya, Yoshihiko; Wakabayashi, Hiroshi; Tsuji, Hiroshi

    2001-02-01

    Charging test of the ITER CS Model Coil which is the world's largest superconducting pulse coil and the CS Insert Coil had started at April 11, 2000 and had completed at August 18, 2000. In the campaign, total shot numbers were 356 and the size of the data file in the DAS (Data Acquisition System) was over 20 GB. This report is a database that consists of the log list and the log sheets of every shot. One can access the database, make a search, and browse results via Internet (http://1ogwww.naka.jaeri.go.jp). The database will be useful to quick search to choose necessary shots. (author)

  3. Large magnetic coils for fusion technology

    International Nuclear Information System (INIS)

    Komarek, P.; Ulbricht, A.

    1989-01-01

    This paper reviews the current status of research in this field and outlines future tasks and experiments for the Next European Torus (NET). Research and development work accomplished so far permits generation and safe operation of magnetic fields up to 9 T by means of NbTi coils. Fields up to 11 T are feasible if the coils are cooled with superfluid helium at 1.8 K. The potential of the Nb 3 Sn coils promise achievement of magnetic fields between 12 and 13 T. (MM) [de

  4. Functional Detachment of Totalitarian Nazi Architecture

    Science.gov (United States)

    Antoszczyszyn, Marek

    2017-10-01

    The paper describes the systematization process of architectural styles in use during Nazi period in Germany between 1933-45. In the results of the research some regularity about strict concern between function & styling has been observed. Using comparison & case study as well as analytical methods there were pointed out characteristic features of more than 500 objects’ architectural appearance that helped to specify their styling & group them into architectural trends. Ultimately the paper proves that the found trends of architectural styling could be collected by functional detachment key. This observation explains easy to recognize even nowadays traceability – so characteristic to Nazi German architecture. Facing today pluralism in architecture, the findings could be a helpful key in the organization of spatial architectural identification process.

  5. Maritime Training Serbian Autonomous Vessel Protection Detachment

    Directory of Open Access Journals (Sweden)

    Šoškić Svetislav D.

    2014-06-01

    Full Text Available The crisis in Somalia has caused appearance of piracy at sea in the Gulf of Aden and the Western Indian Ocean. Somali pirates have become a threat to economic security of the world because almost 30 percent of world oil and 20 percent of global trade passes through the Gulf of Aden. Solving the problem of piracy in this part of the world have included international organizations, institutions, military alliances and the states, acting in accordance with international law and UN Security Council resolutions. The European Union will demonstrate the application of a comprehensive approach to solving the problem of piracy at sea and the crisis in Somalia conducting naval operation — EU NAVFOR Atalanta and operation EUTM under the Common Security and Defense Policy. The paper discusses approaches to solving the problem of piracy in the Gulf of Aden and the crisis in Somalia. Also, the paper points to the complexity of the crisis in Somalia and dilemmas correctness principles that are applied to solve the problem piracy at sea. One of goals is protections of vessels of the World Food Programme (WFP delivering food aid to displaced persons in Somalia. Republic of Serbia joined in this mission and trained and sent one a autonomous team in this military operation for protection WFP. This paper consist the problem of modern piracy, particularly in the area of the Horn of Africa became a real threat for the safety of maritime ships and educational process of Serbian Autonomous vessel protection detachment. Serbian Military Academy adopted and developed educational a training program against piracy applying all the provisions and recommendations of the IMO conventions and IMO model courses for Serbian Autonomous vessel protection detachment.

  6. Missed retinal breaks in rhegmatogenous retinal detachment

    Directory of Open Access Journals (Sweden)

    Brijesh Takkar

    2016-12-01

    Full Text Available AIM: To evaluate the causes and associations of missed retinal breaks (MRBs and posterior vitreous detachment (PVD in patients with rhegmatogenous retinal detachment (RRD. METHODS: Case sheets of patients undergoing vitreo retinal surgery for RRD at a tertiary eye care centre were evaluated retrospectively. Out of the 378 records screened, 253 were included for analysis of MRBs and 191 patients were included for analysis of PVD, depending on the inclusion criteria. Features of RRD and retinal breaks noted on examination were compared to the status of MRBs and PVD detected during surgery for possible associations. RESULTS: Overall, 27% patients had MRBs. Retinal holes were commonly missed in patients with lattice degeneration while missed retinal tears were associated with presence of complete PVD. Patients operated for cataract surgery were significantly associated with MRBs (P=0.033 with the odds of missing a retinal break being 1.91 as compared to patients with natural lens. Advanced proliferative vitreo retinopathy (PVR and retinal bullae were the most common reasons for missing a retinal break during examination. PVD was present in 52% of the cases and was wrongly assessed in 16%. Retinal bullae, pseudophakia/aphakia, myopia, and horse shoe retinal tears were strongly associated with presence of PVD. Traumatic RRDs were rarely associated with PVD. CONCLUSION: Pseudophakic patients, and patients with retinal bullae or advanced PVR should be carefully screened for MRBs. Though Weiss ring is a good indicator of PVD, it may still be over diagnosed in some cases. PVD is associated with retinal bullae and pseudophakia, and inversely with traumatic RRD.

  7. Use of ocular ultrasound for the evaluation of retinal detachment.

    Science.gov (United States)

    Shinar, Zachary; Chan, Linda; Orlinsky, Michael

    2011-01-01

    Retinal detachment is an ocular emergency posing diagnostic difficulty for the emergency practitioner. Direct fundoscopy and visual field testing are difficult to perform and do not completely rule out retinal detachment. Ophthalmologists use ocular ultrasound to enhance their clinical acumen in detecting retinal detachments (RD), and bedside ultrasound capability is readily available to many emergency practitioners (EP). Our study sought to assess whether ocular ultrasound would be a helpful adjunct for the diagnosis of RD for the practicing EP. This was a prospective observational study with a convenience sample of patients. As part of a general course on emergency ultrasonography, practitioners received a 30-min training session on ocular ultrasound before beginning the study. Trained practitioners submitted ultrasound scans with interpretation on patients with signs and symptoms consistent with retinal detachment. Thirty-one of the 72 practitioners trained submitted ocular ultrasound reports on patients presenting to the Emergency Department with concerns for retinal detachments. EPs achieved a 97% sensitivity (95% confidence interval [CI] 82-100%) and 92% specificity (95% CI 82-97%) on 92 examinations (29 retinal detachments). Disc edema and vitreous hemorrhage accounted for false positives, and a subacute retinal detachment accounted for the only false negative. These data show that trained emergency practitioners can use ocular ultrasound as an adjunct to their clinical assessment for retinal detachment. Copyright © 2011 Elsevier Inc. All rights reserved.

  8. Risk of Retinal Detachment After Pediatric Cataract Surgery

    DEFF Research Database (Denmark)

    Haargaard, Birgitte; Andersen, Elisabeth W; Oudin, Anna

    2014-01-01

    was based on medical chart review. RESULTS: Among 1043 eyes of 656 children undergoing surgery for pediatric cataract, 25 eyes (23 children) developed retinal detachment at a median time of 9.1 years after surgery. The overall 20-year risk of retinal detachment was 7% (95% confidence interval [CI]: 3...

  9. Frictional and elastic energy in gecko adhesive detachment.

    Science.gov (United States)

    Gravish, Nick; Wilkinson, Matt; Autumn, Kellar

    2008-03-06

    Geckos use millions of adhesive setae on their toes to climb vertical surfaces at speeds of over 1 m s(-1). Climbing presents a significant challenge for an adhesive since it requires both strong attachment and easy, rapid removal. Conventional pressure-sensitive adhesives are either strong and difficult to remove (e.g. duct tape) or weak and easy to remove (e.g. sticky notes). We discovered that the energy required to detach adhering tokay gecko setae (W(d)) is modulated by the angle (theta) of a linear path of detachment. Gecko setae resist detachment when dragged towards the animal during detachment (theta = 30 degrees ) requiring W(d) = 5.0+/-0.86(s.e.) J m(-2) to detach, largely due to frictional losses. This external frictional loss is analogous to viscous internal frictional losses during detachment of pressure-sensitive adhesives. We found that, remarkably, setae possess a built-in release mechanism. Setae acted as springs when loaded in tension during attachment and returned elastic energy when detached along the optimal path (theta=130 degrees ), resulting in W(d) = -0.8+/-0.12 J m(-2). The release of elastic energy from the setal shaft probably causes spontaneous release, suggesting that curved shafts may enable easy detachment in natural, and synthetic, gecko adhesives.

  10. Risk of progression in macula-on rhegmatogenous retinal detachment.

    Science.gov (United States)

    Callizo, Josep; Pfeiffer, Sebastian; Lahme, Eva; van Oterendorp, Christian; Khattab, Mohammed; Bemme, Sebastian; Kulanga, Miroslav; Hoerauf, Hans; Feltgen, Nicolas

    2017-08-01

    To identify factors that may lead to a rapid progression in macula-on rhegmatogenous retinal detachment (RRD), in particular, those that may lead to macular involvement. Observational, prospective, single-center study. Patients referred for surgery due to primary rhegmatogenous retinal detachment with the macula on between 2009 and 2013 were included. Relevant factors analyzed included age, time delay until surgery, lens status, myopia, the detachment's location and configuration as well as number, size and type of retinal breaks. Eyes underwent optical coherence tomography to detect macular detachment. A multivariate analysis was performed to investigate the effect of several factors in the progression of retinal detachment. A total of 116 eyes of 116 patients were included. Mean time delay between admission and surgery was 1.8 ± 1.4 days. Progression was observed in 19.8% of the eyes. Of those, 47.8% presented macular detachment. Ten of the 11 (90.9%) eyes presenting progression involving the macula also exhibited a bullous configuration, which was the only parameter that correlated significantly with detachment progression in patients with (p = 0.0036) and without (p = 0.0014) macular involvement. For the first time in a prospective trial, a bullous configuration was found to be a highly significant predictor for progression in macula-on detachments. Our data support prompt surgery in patients diagnosed with bullous macula-on RRD.

  11. DETACHMENT OF HUMAN FIBROBLASTS FROM FEP-TEFLON SURFACES

    NARCIS (Netherlands)

    VANKOOTEN, TG; SCHAKENRAAD, JM; VANDERMEI, HC; BUSSCHER, HJ

    1991-01-01

    In this study a comparison is made between the detachment behavior of human fibroblasts adhered to hydrophobic FEP-Teflon (water contact angle 109 degrees) and to hydrophilic glass (water contact angle smaller than 15 degrees) during exposure to a laminar, incrementally loaded flow. Detachment from

  12. Recalcitrance of Streptococcus mutans biofilms towards detergent-stimulated detachment

    NARCIS (Netherlands)

    Landa, AS; van de Belt-Gritter, B; van der Mei, HC; Busscher, HJ

    The biofilm mode of growth protects the plaque microorganisms against environmental attacks, such as from antimicrobials or detergents. Detergents have a demonstrated ability to detach initially adhering bacteria from enamel surfaces, but the ability of detergent components to detach plaque bacteria

  13. MACULAR DETACHMENT ASSOCIATED WITH INTRACHOROIDAL CAVITATION IN NONPATHOLOGICAL MYOPIC EYES.

    Science.gov (United States)

    Ando, Yoshimasa; Inoue, Makoto; Ohno-Matsui, Kyoko; Kusumi, Yumi; Iida, Tomohiro; Hirakata, Akito

    2015-10-01

    To report the characteristics of a macular detachment associated with peripapillary intrachoroidal cavitation (ICC) and the outcomes of vitrectomy. The medical records of 69 eyes of 61 patients who underwent vitrectomy for macular detachment or macular retinoschisis but without vitreomacular traction or optic disc pit were reviewed. Optical coherence tomography was used to determine the morphology of the ICC. The outcomes of vitrectomy including the creation of a posterior vitreous detachment and internal limiting membrane peeling were evaluated. An ICC was detected in 3 of 3 eyes without pathologic myopia but none in 66 eyes with pathologic myopia (P detachment in all eyes. Optical coherence tomography detected a connection between the vitreous cavity and the ICC in two eyes with pit-like splitting and between the subretinal space and the ICC in two eyes. The macular detachment was resolved 5 months to 6 months postoperatively with improvement of vision. A macular detachment with ICC can be present in nonpathological myopic eyes. Vitreous surgery to create a posterior vitreous detachment with internal limiting membrane peeling may help resolve the macular detachment.

  14. Retinal detachment in black South Africans | Peters | South African ...

    African Journals Online (AJOL)

    Rhegmatogenous retinal detachments seen in black patients attending King Edward VIII Hospital Ophthalmology Clinic over a 5-year period from January 1987 to December 1991 were reviewed. Penetrating trauma and diabetic retinopathy were excluded. There were 114 detachments in 112 patients, which gave incidence ...

  15. Incidence and Pattern of Retinal Detachment in a Tertiary Eye ...

    African Journals Online (AJOL)

    Objectives: The aim was to determine the hospital incidence, pattern and clinical presentation of retinal detachment at the Guinness Eye Center, Onitsha, Nigeria. Materials and Methods: Case files of all retinal detachment patients seen at the Guinness Eye Center Onitsha between June 1997 and May 2012 were reviewed.

  16. Flexible eddy current coil arrays

    International Nuclear Information System (INIS)

    Krampfner, Y.; Johnson, D.P.

    1987-01-01

    A novel approach was devised to overcome certain limitations of conventional eddy current testing. The typical single-element hand-wound probe was replaced with a two dimensional array of spirally wound probe elements deposited on a thin, flexible polyimide substrate. This provides full and reliable coverage of the test area and eliminates the need for scanning. The flexible substrate construction of the array allows the probes to conform to irregular part geometries, such as turbine blades and tubing, thereby eliminating the need for specialized probes for each geometry. Additionally, the batch manufacturing process of the array can yield highly uniform and reproducible coil geometries. The array is driven by a portable computer-based eddy current instrument, smartEDDY/sup TM/, capable of two-frequency operation, and offers a great deal of versatility and flexibility due to its software-based architecture. The array is coupled to the instrument via an 80-switch multiplexer that can be configured to address up to 1600 probes. The individual array elements may be addressed in any desired sequence, as defined by the software

  17. Coil geometry effects on scanning single-coil magnetic induction tomography

    Science.gov (United States)

    Feldkamp, Joe R.; Quirk, Stephen

    2017-09-01

    Alternative coil designs for single coil magnetic induction tomography are considered in this work, with the intention of improving upon the standard design used previously. In particular, we note that the blind spot associated with this coil type, a portion of space along its axis where eddy current generation can be very weak, has an important effect on performance. The seven designs tested here vary considerably in the size of their blind spot. To provide the most discerning test possible, we use laboratory phantoms containing feature dimensions similar to blind spot size. Furthermore, conductivity contrasts are set higher than what would occur naturally in biological systems, which has the effect of weakening eddy current generation at coil locations that straddle the border between high and low conductivity features. Image reconstruction results for the various coils show that coils with smaller blind spots give markedly better performance, though improvements in signal-to-noise ratio could alter that conclusion.

  18. A coil test facility for the cryogenic tests of the JT-60SA TF coils

    International Nuclear Information System (INIS)

    Chantant, M.; Genini, L.; Bayetti, P.; Millet, F.; Wanner, M.; Massaut, V.; Corte, A. Della; Ardelier-Desage, F.; Catherine-Dumont, V.; Dael, A.; Decool, P.; Donati, A.; Duchateau, J.L.; Garibaldi, P.; Girard, S.; Hatchressian, J.C.; Fejoz, P.; Jamotton, P.; Jourdheuil, L.; Juster, F.P.

    2011-01-01

    In the framework of the Broader Approach Activities, the EU will deliver to Japan the 18 superconducting coils, which constitute the JT-60SA Toroidal field magnet. These 18 coils, manufactured by France and Italy, will be cold tested before shipping to Japan. For this purpose, the European Joint Undertaking for ITER, the Development of Fusion Energy ('Fusion for Energy', F4E) and the European Voluntary Contributors are collaborating to design and set-up a coil test facility (CTF) and to perform the acceptance test of the 18 JT-60SA Toroidal Field (TF) coils. The test facility is designed to test one coil at a time at nominal current and cryogenic temperature. The test of the first coil of each manufacturer includes a quench triggered by increasing the temperature. The project is presently in the detailed design phase.

  19. Dissociative detachment relates to psychotic symptoms and personality decompensation.

    Science.gov (United States)

    Allen, J G; Coyne, L; Console, D A

    1997-01-01

    Previous studies have addressed the prominence of psychotic symptoms in conjunction with multiple personality disorder (now dissociative identity disorder). The present study examines the relation between psychotic symptoms and a more pervasive form of dissociative disturbance, namely dissociative detachment. Two hundred sixty-six women in inpatient treatment for severe trauma-related disorders completed the Dissociative Experiences Scale (DES), and 102 of these patients also completed the Millon Clinical Multiaxial Inventory (MCMI-III). A factor analysis of the DES yielded two dimensions of dissociative detachment: detachment from one's own actions and detachment from the self and the environment. Each of these DES dimensions relates strongly to the thought disorder and schizotypal personality disorder scales of the MCMI-III. We propose that severe dissociative detachment, by virtue of loosening the moorings in inner and outer reality, is conducive to psychotic symptoms and personality decompensation.

  20. Ocular hemodynamics in patients with rhegmatogenous retinal detachment

    Directory of Open Access Journals (Sweden)

    N. H. Zavgorodnya

    2014-10-01

    Full Text Available Aim. In case of retinal detachment atrophic processes lead to irreversible loss of functions within 4–6 days, it happens on underlying low ocular blood flow. In order to evaluate the degree of violation of regional hemodynamics in patients with retinal detachment two groups of patients were examined: the main group (52 patients with rhegmatogenous retinal detachment and the control group (24 myopic patients with lattice form of peripheral chorioretinal dystrophy. Methods and results. Doppler and reography results had been compared, significant decrease of blood flow in patients with retinal detachment was found. No differences between affected and fellow eye in these patients, close negative correlation between the level of ocular blood flow and the degree of myopia in the control group. Conclusion. This demonstrates the feasibility of actions to improve regional blood flow in patients operated on for retinal detachment.

  1. Posterior vitreous detachment and retinal detachment after implantation of the Visian phakic implantable collamer lens.

    Science.gov (United States)

    Bamashmus, Mahfouth A; Al-Salahim, Seddique A; Tarish, Nabil A; Saleh, Mahmoud F; Mahmoud, Hatem A; Elanwar, Mohamed F; Awadalla, Mohamed A

    2013-01-01

    To evaluate the vitreoretinal complications in myopes after Visian implantable collamer lenses (ICL) implantation. This is a retrospective, observational, non-comparative clinical study that evaluated 617 consecutive myopes who underwent ICL implantation at the Department of Refractive Surgery, Yemen Magrabi Hospital, Sana'a, Yemen between July 2006 and May 2010. Follow up ranged from 6 months to 40 months. Preoperative and postoperative patient evaluation included manifest and cycloplegic refractions, uncorrected (UCVA) and best spectacle-corrected visual acuity (BSCVA), slit-lamp biomicroscopy, intraocular pressure and dilated retinal examination. Investigations included corneal topography, central corneal thickness, anterior chamber depth and white to white diameter. Retinal diseases and complications were recorded and analyzed preoperatively and postoperatively. Preoperatively, 61 (9.9%) eyes had posterior segment pathology requiring prophylactic laser photocoagulation. One eye developed spontaneous rhegmatogenous retinal detachment (RRD), one eye developed traumatic retinal detachment and two eyes required laser treatment postoperatively. The overall retinal detachment rate post-ICL was 0.32%. Posterior segment complications are rare after ICL implantation but dilated vitreoretinal assessment is important before and after the procedure. Patients with suspicious retinal lesions need a comprehensive vitreoretinal evaluation by a retinal specialist. If a patient develops floaters or blurry vision he/she requires further assessment by a vitreoretinal specialist.

  2. Functional Analysis of the Bacteriophage T4 Rad50 Homolog (gp46) Coiled-coil Domain.

    Science.gov (United States)

    Barfoot, Tasida; Herdendorf, Timothy J; Behning, Bryanna R; Stohr, Bradley A; Gao, Yang; Kreuzer, Kenneth N; Nelson, Scott W

    2015-09-25

    Rad50 and Mre11 form a complex involved in the detection and processing of DNA double strand breaks. Rad50 contains an anti-parallel coiled-coil with two absolutely conserved cysteine residues at its apex. These cysteine residues serve as a dimerization domain and bind a Zn(2+) cation in a tetrathiolate coordination complex known as the zinc-hook. Mutation of the zinc-hook in bacteriophage T4 is lethal, indicating the ability to bind Zn(2+) is critical for the functioning of the MR complex. In vitro, we found that complex formation between Rad50 and a peptide corresponding to the C-terminal domain of Mre11 enhances the ATPase activity of Rad50, supporting the hypothesis that the coiled-coil is a major conduit for communication between Mre11 and Rad50. We constructed mutations to perturb this domain in the bacteriophage T4 Rad50 homolog. Deletion of the Rad50 coiled-coil and zinc-hook eliminates Mre11 binding and ATPase activation but does not affect its basal activity. Mutation of the zinc-hook or disruption of the coiled-coil does not affect Mre11 or DNA binding, but their activation of Rad50 ATPase activity is abolished. Although these mutants excise a single nucleotide at a normal rate, they lack processivity and have reduced repetitive exonuclease rates. Restricting the mobility of the coiled-coil eliminates ATPase activation and repetitive exonuclease activity, but the ability to support single nucleotide excision is retained. These results suggest that the coiled-coiled domain adopts at least two conformations throughout the ATPase/nuclease cycle, with one conformation supporting enhanced ATPase activity and processivity and the other supporting nucleotide excision. © 2015 by The American Society for Biochemistry and Molecular Biology, Inc.

  3. Computational characterization of parallel dimeric and trimeric coiled-coils using effective amino acid indices.

    Science.gov (United States)

    Li, Chen; Wang, Xiao-Feng; Chen, Zhen; Zhang, Ziding; Song, Jiangning

    2015-02-01

    The coiled-coil, which consists of two or more α-helices winding around each other, is a ubiquitous and the most frequently observed protein-protein interaction motif in nature. The coiled-coil is known for its straightforward heptad repeat pattern and can be readily recognized based on protein primary sequences, exhibiting a variety of oligomer states and topologies. Due to the stable interaction formed between their α-helices, coiled-coils have been under close scrutiny to design novel protein structures for potential applications in the fields of material science, synthetic biology and medicine. However, their broader application requires an in-depth and systematic analysis of the sequence-to-structure relationship of coiled-coil folding and oligomeric formation. In this article, we propose a new oligomerization state predictor, termed as RFCoil, which exploits the most useful and non-redundant amino acid indices combined with the machine learning algorithm - random forest (RF) - to predict the oligomeric states of coiled-coil regions. Benchmarking experiments show that RFCoil achieves an AUC (area under the ROC curve) of 0.849 on the 10-fold cross-validation test using the training dataset and 0.855 on the independent test using the validation dataset, respectively. Performance comparison results indicate that RFCoil outperforms the four existing predictors LOGICOIL, PrOCoil, SCORER 2.0 and Multicoil2. Furthermore, we extract a number of predominant rules from the trained RF model that underlie the oligomeric formation. We also present two case studies to illustrate the applicability of the extracted rules to the prediction of coiled-coil oligomerization state. The RFCoil web server, source codes and datasets are freely available for academic users at http://protein.cau.edu.cn/RFCoil/.

  4. 12 tesla test coil. Annual progress report

    International Nuclear Information System (INIS)

    1979-01-01

    The Plasma Fusion Center at MIT has been charged with responsibility for the design, development, fabrication and test operation of a Niobium-3-Tin Superconducting Test Coil. Research is described on DOE's 12 tesla coil demonstration program in which several one-meter diameter superconducting test coils will be inserted and tested in DOE's High Field Test Facility at the Lawrence Livermore Laboratories. The work was initiated at the start of FY 79. FY 79 saw the completion of our Preliminary Design and the initiation of three (3) subcontracts: (1) Westinghouse review of the Preliminary Design, (II) Supercon, Inc. development of a tubular copper matrix, Nb 3 Sn Superconductor and (III) Airco optimization of the LCP-W Nb 3 Sn superconductor for 12T service. In addition, Airco was charged with the production of a 1000 foot length of model 15,000A conductor. Coil winding exercises were initiated at the Everson Electric Company

  5. Superconducting magnet coils protection schemes and apparatus

    International Nuclear Information System (INIS)

    Kuchinski, V.; Bulgakov, S.; Larionov, B.; Mikhailov, N.; Silin, V.

    1995-01-01

    The circuitry of the superconducting coils protection system of the large fusion installations is analyzed. The requirements to the switches and several options of the circuit breakers and making switches with the data of their experimental study are discussed. (orig.)

  6. Design considerations for ITER toroidal field coils

    International Nuclear Information System (INIS)

    Kalsi, S.S.; Lousteau, D.C.; Miller, J.R.

    1987-01-01

    The International Thermonuclear Experimental Reactor (ITER) is a new tokamak design project with joint participation from Europe, Japan, the Union of Soviet Socialist Republics (U.S.S.R.), and the United States. This paper describes a magnetic and mechanical design methodology for toroidal field (TF) coils that employs Nb 3 Sn superconductor technology. Coil winding is sized by using conductor concepts developed for the U.S. TIBER concept. Manifold concepts are presented for the complete cooling system. Also included are concepts for the coil structural arrangement. The effects of in-plane and out-of-plane loads are included in the design considerations for the windings and case. Concepts are presented for reacting these loads with a minimum amount of additional structural material. Concepts discussed in this paper could be considered for the ITER TF coils

  7. Fields analysis of TFR 604 copper coils

    International Nuclear Information System (INIS)

    Bourrier, P.; Dubois, C.; Deschamps, P.; Millard, A.

    1979-01-01

    This paper describes the analysis of the toroidal Bitter type coils of TFR-604 fusion device. Electric, magnetic and mechanical fields have been investigated. The major difficulty arises from the quite complicated shape of the structure

  8. Tricuspid valve detachment in closure of congenital ventricular septal defect.

    Science.gov (United States)

    Zhao, Jinping; Li, Jun; Wei, Xiang; Zhao, Bo; Sun, Wei

    2003-01-01

    From January 1991 through December 2001, 600 patients underwent closure of a perimembranous ventricular septal defect through a right atrial approach at our institution. In 122 of these patients, the operation included temporary detachment of a tricuspid valve septal leaflet from the annulus to allow complete visualization of a perimembranous ventricular septal defect The mean age of the patients at surgery was 4.6 years in those who underwent leaflet detachment and 4.7 years in the 478 patients who did not (P > 0.05). Preoperatively, all patients were in sinus rhythm. Echocardiography showed trivial tricuspid regurgitation in 21 of the patients undergoing detachment and in 39 of the non-detachment patients. There was no difference in bypass time or aortic cross-clamp time between the 2 groups. Postoperatively, 3 patients in the non-detachment group had heart block; all other patients were in sinus rhythm. Echocardiograms on the 7th postoperative day showed small residual ventricular septal defects in none of the patients who underwent valve detachment and in 10 of the non-detachment patients; mild tricuspid regurgitation was present in 12 non-detachment patients only; and trivial tricuspid regurgitation was present in 19 patients who underwent valve detachment and in 29 who did not. There was no hospital death in either group. Long-term follow-up showed no progression of tricuspid regurgitation or tricuspid stenosis. All patients remained in sinus rhythm. This study suggests that tricuspid valve detachment is a safe, effective technique that improves exposure for ventricular septal defect repair and does not adversely affect valve competence.

  9. Pathogenesis of rhegmatogenous retinal detachment: predisposing anatomy and cell biology.

    Science.gov (United States)

    Mitry, Danny; Fleck, Brian W; Wright, Alan F; Campbell, Harry; Charteris, David G

    2010-01-01

    The pathogenesis of rhegmatogenous retinal detachment is complex, and our knowledge of the exact mechanism of vitreoretinal attachment and detachment remains incomplete. We performed a Medline, Ovid, and EMBASE search using search words rhegmatogenous, retinal detachment, vitreous, and retinal adhesion. All appropriate articles were reviewed, and the evidence was compiled. Cortical vitreous contains fibrillar collagens type II, V/XI, and IX. The inner limiting membrane of the retina contains collagens type I, IV, VI, and XVIII as well as numerous other glycoproteins and potential adhesion molecules. The distribution and age-related changes in the structure of these molecules play an important role in the formation of a retinal break, which may compromise and disrupt the normal mechanisms of neurosensory retinal adhesion. Rhegmatogenous retinal detachment development is intimately related to changes in the fibrillar structure of the aging vitreous culminating in posterior vitreous detachment with regions of persistent and tangential vitreoretinal traction predisposing to retinal tear formation. A complex interplay of factors such as weakening of vitreoretinal adhesion, posterior migration of the vitreous base, and molecular changes at the vitreoretinal interface are important in predisposing to focal areas of vitreoretinal traction precipitating rhegmatogenous retinal detachment. Once formed, the passage of liquefied vitreous through a retinal break may overwhelm normal neurosensory-retinal pigment epithelium adhesion perpetuating and extending detachment and causing visual loss. To understand the molecular events underlying rhegmatogenous retinal detachment so that new therapies can be developed, it is important to appreciate the structural organization of the vitreous, the biology underlying vitreous liquefaction and posterior vitreous detachment, and the mechanisms of vitreoretinal attachment and detachment.

  10. Umbilical coiling index & the perinatal outcome.

    Science.gov (United States)

    Devaru, Dakshayini; Thusoo, Meghna

    2012-02-01

    To correlate the perinatal outcome by noting the umbilical coiling index. The umbilical cords of the babies born to 100 women, who delivered either vaginally or by lower segment cesarean section, were examined and umbilical coiling index was calculated. There was significant correlation (p value 0.003) between the hypercoiled cords (UCI >90th percentile) and intrauterine growth restriction of the babies. Apgar score at 1 min UCI UCI UCI >10th percentile is associated with intra uterine growth restriction.

  11. Heterogeneous Superconducting Low-Noise Sensing Coils

    Science.gov (United States)

    Hahn, Inseob; Penanen, Konstantin I.; Ho Eom, Byeong

    2008-01-01

    A heterogeneous material construction has been devised for sensing coils of superconducting quantum interference device (SQUID) magnetometers that are subject to a combination of requirements peculiar to some advanced applications, notably including low-field magnetic resonance imaging for medical diagnosis. The requirements in question are the following: The sensing coils must be large enough (in some cases having dimensions of as much as tens of centimeters) to afford adequate sensitivity; The sensing coils must be made electrically superconductive to eliminate Johnson noise (thermally induced noise proportional to electrical resistance); and Although the sensing coils must be cooled to below their superconducting- transition temperatures with sufficient cooling power to overcome moderate ambient radiative heat leakage, they must not be immersed in cryogenic liquid baths. For a given superconducting sensing coil, this combination of requirements can be satisfied by providing a sufficiently thermally conductive link between the coil and a cold source. However, the superconducting coil material is not suitable as such a link because electrically superconductive materials are typically poor thermal conductors. The heterogeneous material construction makes it possible to solve both the electrical- and thermal-conductivity problems. The basic idea is to construct the coil as a skeleton made of a highly thermally conductive material (typically, annealed copper), then coat the skeleton with an electrically superconductive alloy (typically, a lead-tin solder) [see figure]. In operation, the copper skeleton provides the required thermally conductive connection to the cold source, while the electrically superconductive coating material shields against Johnson noise that originates in the copper skeleton.

  12. Coil tests and superconductor code calculations for the stellarator W7-X coils

    Science.gov (United States)

    Baldzuhn, J.; Ehmler, H.; Hoelting, A.; Hertel, K.; Sborchia, C.; Genini, L.; Schild, T.

    2006-07-01

    For the stellarator Wendelstein 7-X, a plasma fusion experiment, the performance of the superconducting coils is tested in a cryogenic test facility. Focus is on the quench behaviour of these coils. Some key data of the coils are given here. The coil quench data, obtained during the tests, are compared to GANDALF code calculations. GANDALF is a one-dimensional finite elements code for the simulation of the quench properties of superconducting CICC cables. Good consistency between measurement and calculation is found for the development of the resistive voltage and temperature increase during the quench.

  13. Magnetic resonance dacryocystography: comparison between conventional surface coils and microscopic coils

    International Nuclear Information System (INIS)

    Abreu Junior, Luiz de; Wolosker, Angela Maria Borri; Borri, Maria Lucia; Galvao Filho, Mario de Melo; Hartmann, Luiz Guilherme de Carvalho; D'Ippolito, Giuseppe; Castro, Claudio Campi de

    2008-01-01

    Objective: Magnetic resonance imaging has been utilized in the evaluation of the lacrimal apparatus with some advantages over conventional dacryocystography. The present study was aimed at acquiring high resolution images utilizing microscopic coils for evaluating typical structures of the lacrimal apparatus as compared with the findings observed with conventional surface coils. Materials and methods: Five asymptomatic volunteers with no history of epiphora were submitted to high-field magnetic resonance imaging with microscopic and conventional surface coils, and STIR sequence after instillation of saline solution. The definition of normal anatomic structures of lacrimal apparatuses was compared utilizing conventional and microscopic surface coils. Based on a consensual scoring system, the mean values for each structure were calculated by two observers. Results: In 90% of cases, higher scores were attributed to images acquired with the microscopic coil. On average, a 1.17 point increase was observed in the scoring of anatomic structures imaged with the microscopic coil. Additionally, a subjective improvement was observed in the signal-to-noise ratio with the microscopic coil. Conclusion: Magnetic resonance dacryocystography with microscopic coils is the appropriate method for evaluating the lacrimal apparatus, providing images with better quality as compared with those acquired with conventional surface coils. (author)

  14. Coiled coil interactions for the targeting of liposomes for nucleic acid delivery.

    Science.gov (United States)

    Oude Blenke, Erik E; van den Dikkenberg, Joep; van Kolck, Bartjan; Kros, Alexander; Mastrobattista, Enrico

    2016-04-28

    Coiled coil interactions are strong protein-protein interactions that are involved in many biological processes, including intracellular trafficking and membrane fusion. A synthetic heterodimeric coiled-coil forming peptide pair, known as E3 (EIAALEK)3 and K3 (KIAALKE)3 was used to functionalize liposomes encapsulating a splice correcting oligonucleotide or siRNA. These peptide-functionalized vesicles are highly stable in solution but start to cluster when vesicles modified with complementary peptides are mixed together, demonstrating that the peptides quickly coil and crosslink the vesicles. When one of the peptides was anchored to the cell membrane using a hydrophobic cholesterol anchor, vesicles functionalized with the complementary peptide could be docked to these cells, whereas non-functionalized cells did not show any vesicle tethering. Although the anchored peptides do not have a downstream signaling pathway, microscopy pictures revealed that after four hours, the majority of the docked vesicles were internalized by endocytosis. Finally, for the first time, it was shown that the coiled coil assembly at the interface between the vesicles and the cell membrane induces active uptake and leads to cytosolic delivery of the nucleic acid cargo. Both the siRNA and the splice correcting oligonucleotide were functionally delivered, resulting respectively in the silencing or recovery of luciferase expression in the appropriate cell lines. These results demonstrate that the docking to the cell by coiled coil interaction can induce active uptake and achieve the successful intracellular delivery of otherwise membrane impermeable nucleic acids in a highly specific manner.

  15. COMPASS magnetic field coils and structure systems

    International Nuclear Information System (INIS)

    Crossland, R.T.; Booth, J.A.; Hayward, R.J.; Keogh, P.; Pratt, A.P.

    1987-01-01

    COMPASS is a new experimental toroidal assembly of compact design and with a wide range of physics objectives. It is required to operate either as a Tokamak or as a Reversed Field Pinch with interchangeable circular and dee-section vacuum vessels. The Toroidal field is produced by 16 rectangular coils of 4 turns with tapered conductors on the inside which nest together to form a vault to resist the centering forces. The coils are designed to produce a maximum field on axis of 2.1T which requires a current of 91 kA per turn. Two central solenoids and five pairs of coils symmetrically positioned above and below the machine equator provide the poloidal field. Both coil systems are supported form a mechanical support structure which surrounds the machine. This is primarily designed to resist out-of-plane forces on the TF coils but also acts as the base support for the PF coils and vacuum vessels. An illustration of the COMPASS Load Assembly is given and shows the D-shaped vacuum vessel, the major components and the various field windings

  16. ISX toroidal field coil design and analysis

    International Nuclear Information System (INIS)

    Hussung, R.O.; Lousteau, D.C.; Johnson, N.E.; Weed, R.A.

    1975-01-01

    Structural design and analysis aspects of the toroidal field coils for the Impurity Study Experiment (ISX) tokamak are discussed. The overall mechanical design of ISX is predicated on the ability to remove the upper segment of the toroidal field coils to allow access to the toroidal vacuum vessel. The high current, 120 kA, capability of the new 74 MW power supply, coupled with the modest field requirement of ISX, allows the use of room temperature copper coils. Seventy-two turns, grouped into 18 coils, generate a magnet field of 18 kG at the major radius of 90 cm. Finite element structural analysis codes were utilized to determine the distribution of stresses and deflections around a typical turn. Initial material distribution on a coil was sized using the two-dimensional program FEATS. The resulting coil design was then coupled to the center bucking and out-of-plane restraint systems utilizing the NASTRAN code. The boundary conditions for the analytical models used in the two programs were then iterated, reaching satisfactory agreement as to stress contours and location for the joints

  17. Poloidal coils for the Large Helical Device (LHD)

    International Nuclear Information System (INIS)

    Takahata, K.; Satow, T.; Iwamoto, A.

    1996-01-01

    Poloidal coil system of the Large Helical Device (LHD) consists of three pairs of circular solenoids; Inner Vertical (IV), Inner shaping (IS) and Outer Vertical (OV) coils. Forced flow cooling is adopted as a cooling method of the poloidal coils. The conductors of the poloidal coils are Nb-Ti cable-in-conduit types. Each coil consists of eight double-pancake coils, and coolant flows in parallel from the inner turns to the outer turns. A superconducting joint technique is adopted in the joints among the double-pancake coils. Miniaturized joints and severe quality control bring the reduction of error field. (author)

  18. HydroSoft coil versus HydroCoil for endovascular aneurysm occlusion study: A single center experience

    International Nuclear Information System (INIS)

    Guo Xinbin; Fan Yimu; Zhang Jianning

    2011-01-01

    Background and purpose: The HydroCoil Embolic System (HES) was developed to reduce recurrences of aneurysms relative to platinum coils. But the HydroCoil Embolic System was characterized with many limitations. The manufacturer had recognized the challenge and recently a new design of hydrogel-coated coil-HydroSoft has become available in the market as the new generation HydroCoil. We reported our initial experience using HydroSoft coil versus HydroCoil in our center. Methods: 75 aneurysms embolized primarily using HydroSoft Coils from July 2008 to May 2009 were compared with 66 volume- and shape-matched aneurysms treated with HydroCoils from March 2006 to August 2008. Outcome measures included length and number of coils used, contrast volume, and length of hospital stay. During embolization, a stable framework was first established with bare coils, and hydrogel-coated coils were used subsequently to increase the packing density. Follow-up angiographic results 6 months after treatment were evaluated among some of the patients. Results: Successful coil embolization was achieved in all patients. There were no differences in average total coil length used per aneurysm. There were no differences in length of hospital stay and packing density. HydroSoft coils were more suitable using as the finishing or final coil. HydroSoft coil decreased the procedure-related retreated rates, and aneurysm packing was finished with soft, flexible HydroSoft coil and decreased the neck remnant rates. Follow-up angiography in HydroSoft-treated patients at 6 months revealed aneurysm stability without significant residual neck. Conclusions: HydroSoft coil allowed us to deploy coated coils with good packing density. A slight expansion of these coils at the neck can be expected to reduce neck remnant and potentially inhibit recurrence.

  19. Advantages of diabetic tractional retinal detachment repair

    Directory of Open Access Journals (Sweden)

    Sternfeld A

    2015-10-01

    Full Text Available Amir Sternfeld, Ruth Axer-Siegel, Hadas Stiebel-Kalish, Dov Weinberger, Rita Ehrlich Department of Ophthalmology, Rabin Medical Center, Beilinson Campus, Petach Tikva, Israel Purpose: To evaluate the outcomes and complications of patients with diabetic tractional retinal detachment (TRD treated with pars plana vitrectomy (PPV.Patients and methods: We retrospectively studied a case series of 24 eyes of 21 patients at a single tertiary, university-affiliated medical center. A review was carried out on patients who underwent PPV for the management of TRD due to proliferative diabetic retinopathy from October 2011 to November 2013. Preoperative and final visual outcomes, intraoperative and postoperative complications, and medical background were evaluated.Results: A 23 G instrumentation was used in 23 eyes (95.8%, and a 25 G instrumentation in one (4.2%. Mean postoperative follow-up time was 13.3 months (4–30 months. Visual acuity significantly improved from logarithm of the minimum angle of resolution (LogMAR 1.48 to LogMAR 1.05 (P<0.05. Visual acuity improved by ≥3 lines in 75% of patients. Intraoperative complications included iatrogenic retinal breaks in seven eyes (22.9% and vitreal hemorrhage in nine eyes (37.5%. In two eyes, one sclerotomy was enlarged to 20 G (8.3%. Postoperative complications included reoperation in five eyes (20.8% due to persistent subretinal fluid (n=3, vitreous hemorrhage (n=1, and dislocated intraocular lens (n=1. Thirteen patients (54.2% had postoperative vitreous hemorrhage that cleared spontaneously, five patients (20.8% required antiglaucoma medications for increased intraocular pressure, seven patients (29.2% developed an epiretinal membrane, and two patients (8.3% developed a macular hole.Conclusion: Patients with diabetic TRD can benefit from PPV surgery. Intraoperative and postoperative complications can be attributed to the complexity of this disease. Keywords: diabetic retinopathy, proliferative

  20. Structural Correlation of the Neck Coil with the Coiled-coil (CC1)-Forkhead-associated (FHA) Tandem for Active Kinesin-3 KIF13A.

    Science.gov (United States)

    Ren, Jinqi; Huo, Lin; Wang, Wenjuan; Zhang, Yong; Li, Wei; Lou, Jizhong; Xu, Tao; Feng, Wei

    2016-02-12

    Processive kinesin motors often contain a coiled-coil neck that controls the directionality and processivity. However, the neck coil (NC) of kinesin-3 is too short to form a stable coiled-coil dimer. Here, we found that the coiled-coil (CC1)-forkhead-associated (FHA) tandem (that is connected to NC by Pro-390) of kinesin-3 KIF13A assembles as an extended dimer. With the removal of Pro-390, the NC-CC1 tandem of KIF13A unexpectedly forms a continuous coiled-coil dimer that can be well aligned into the CC1-FHA dimer. The reverse introduction of Pro-390 breaks the NC-CC1 coiled-coil dimer but provides the intrinsic flexibility to couple NC with the CC1-FHA tandem. Mutations of either NC, CC1, or the FHA domain all significantly impaired the motor activity. Thus, the three elements within the NC-CC1-FHA tandem of KIF13A are structurally interrelated to form a stable dimer for activating the motor. This work also provides the first direct structural evidence to support the formation of a coiled-coil neck by the short characteristic neck domain of kinesin-3. © 2016 by The American Society for Biochemistry and Molecular Biology, Inc.

  1. Structural Correlation of the Neck Coil with the Coiled-coil (CC1)-Forkhead-associated (FHA) Tandem for Active Kinesin-3 KIF13A*

    Science.gov (United States)

    Ren, Jinqi; Huo, Lin; Wang, Wenjuan; Zhang, Yong; Li, Wei; Lou, Jizhong; Xu, Tao; Feng, Wei

    2016-01-01

    Processive kinesin motors often contain a coiled-coil neck that controls the directionality and processivity. However, the neck coil (NC) of kinesin-3 is too short to form a stable coiled-coil dimer. Here, we found that the coiled-coil (CC1)-forkhead-associated (FHA) tandem (that is connected to NC by Pro-390) of kinesin-3 KIF13A assembles as an extended dimer. With the removal of Pro-390, the NC-CC1 tandem of KIF13A unexpectedly forms a continuous coiled-coil dimer that can be well aligned into the CC1-FHA dimer. The reverse introduction of Pro-390 breaks the NC-CC1 coiled-coil dimer but provides the intrinsic flexibility to couple NC with the CC1-FHA tandem. Mutations of either NC, CC1, or the FHA domain all significantly impaired the motor activity. Thus, the three elements within the NC-CC1-FHA tandem of KIF13A are structurally interrelated to form a stable dimer for activating the motor. This work also provides the first direct structural evidence to support the formation of a coiled-coil neck by the short characteristic neck domain of kinesin-3. PMID:26680000

  2. Functional and anatomical remodeling in human retinal detachment.

    Science.gov (United States)

    de Souza, Clairton F; Kalloniatis, Michael; Polkinghorne, Philip J; McGhee, Charles N J; Acosta, Monica L

    2012-04-01

    Rhegmatogenous retinal detachment is by far the most common indication for retinal surgery and a major cause of severe vision loss. Increased levels of glutamate found in the vitreous of human patients and persistent remodeling, even after reattachment, suggest substantial neurochemical, functional and anatomical changes have occurred in the detached retina. Therefore, this study was designed to characterize the morphological changes and glutamate receptor functionality in human rhegmatogenous retinal detachment. A cation channel permeating probe, agmatine (1-amino-4-guanidobutane; AGB), was employed to track endogenous and kainate (KA) driven channel functionality combined with immunocytochemical characterization of cellular remodeling. In the detached retina increased AGB permeability was identified in the outer retina while there was a decrease in the inner retina in basal conditions. KA receptors exhibited increased AGB permeability in ON bipolar cells and decreased permeability in calbindin labeled inner retinal cells. All retinal detachment samples demonstrated ectopic synaptic protein expression, photoreceptor processes extending toward the inner retina, and other remodeling features of retinal degeneration. These anatomical changes have been demonstrated in animal studies and are novel features unreported in primary cases of human retinal detachment. We conclude that deafferentation in retinal detachment leads to alteration of the glutamatergic pathway. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. A computer investigation of chemically mediated detachment in bacterial biofilms.

    Science.gov (United States)

    Hunt, Stephen M; Hamilton, Martin A; Sears, John T; Harkin, Gary; Reno, Jason

    2003-05-01

    A three-dimensional computer model was used to evaluate the effect of chemically mediated detachment on biofilm development in a negligible-shear environment. The model, BacLAB, combines conventional diffusion-reaction equations for chemicals with a cellular automata algorithm to simulate bacterial growth, movement and detachment. BacLAB simulates the life cycle of a bacterial biofilm from its initial colonization of a surface to the development of a mature biofilm with cell areal densities comparable to those in the laboratory. A base model founded on well established transport equations that are easily adaptable to investigate conjectures at the biological level has been created. In this study, the conjecture of a detachment mechanism involving a bacterially produced chemical detachment factor in which high local concentrations of this detachment factor cause the bacteria to detach from the biofilm was examined. The results show that the often observed 'mushroom'-shaped structure can occur if detachment events create voids so that the remaining attached cells look like mushrooms.

  4. Ethnic variation in rhegmatogenous retinal detachments

    Science.gov (United States)

    Chandra, A; Banerjee, P; Davis, D; Charteris, D

    2015-01-01

    Purpose We aimed to investigate the clinical variation of rhegmatogenous retinal detachments (RD) in patients of different ethnicities. Methods Patients presenting with a primary RD from two ethnic groups were recruited from our tertiary referral hospital between August 2010 and December 2012. Patients who self-reported their ethnic origin either as European Caucasian (EC) or South Asian (SA) were included. Exclusion criteria included trauma, previous vitreoretinal procedures, age under 18 years, complicated cataract surgery and the presence of syndromes known to be associated with a high prevalence of RD. Detailed phenotypic data were collected. Descriptive and comparative statistical analyses were undertaken. Results 1269 Patients were recruited. 1173 (92.4%) were EC. Mean age of onset was 58.3 years (EC) and 54.5 years (SA) (P=0.006). 75.3% EC and 58.4% SA were phakic (Plattice retinal degeneration in the affected eye (P=0.003). Refractive myopia was greater in SA patients (mean: −6.1DS) than EC (−4.2DS) (P=0.032). Additionally, SA patients had a greater mean axial length (25.65 mm) than EC (25.06 mm) (P=0.014). No differences were demonstrated in laterality, family history, type of retinal break or macular status. Conclusions SA patients present with RD at an earlier age and have a more severe phenotype than ECs. Future management strategies for RD may need to reflect these differences. PMID:25853394

  5. SHARPIN Regulates Uropod Detachment in Migrating Lymphocytes

    Directory of Open Access Journals (Sweden)

    Jeroen Pouwels

    2013-11-01

    Full Text Available SHARPIN-deficient mice display a multiorgan chronic inflammatory phenotype suggestive of altered leukocyte migration. We therefore studied the role of SHARPIN in lymphocyte adhesion, polarization, and migration. We found that SHARPIN localizes to the trailing edges (uropods of both mouse and human chemokine-activated lymphocytes migrating on intercellular adhesion molecule-1 (ICAM-1, which is one of the major endothelial ligands for migrating leukocytes. SHARPIN-deficient cells adhere better to ICAM-1 and show highly elongated tails when migrating. The increased tail lifetime in SHARPIN-deficient lymphocytes decreases the migration velocity. The adhesion, migration, and uropod defects in SHARPIN-deficient lymphocytes were rescued by reintroducing SHARPIN into the cells. Mechanistically, we show that SHARPIN interacts directly with lymphocyte-function-associated antigen-1 (LFA-1, a leukocyte counterreceptor for ICAM-1, and inhibits the expression of intermediate and high-affinity forms of LFA-1. Thus, SHARPIN controls lymphocyte migration by endogenously maintaining LFA-1 inactive to allow adjustable detachment of the uropods in polarized cells.

  6. Comparison of surface coil and knee coil for evaluation of the patellar cartilage by MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Steen, M. van den; Maeseneer, M. de E-mail: midema@belgacom.net; Hoste, M.; Vanderdood, K.; Ridder, F. de; Osteaux, M

    2003-07-01

    Purpose: The aim of this work was to compare the knee coil and the surface coil for the visualisation of the patellar cartilage. Materials and methods: In 28 patients (17 women, 11 men) with an average age of 40 years (range 14-76) with knee pain MR was performed. Transverse images were obtained using a fast spin echo proton density weighted sequence on a Philips Gyroscan Intera 1.5 T clinical system. Transverse images were obtained at the level of the patellar cartilage using both the surface and the knee coil. All images were evaluated by consensus of two radiologists. They evaluated a number of quality criteria on a 4-point scale. Criteria for artefacts were also graded on a 4-point scale. Results: For the visualisation of fluid there was no significant difference between the knee coil and the surface coil (P=0.021). For all other criteria regarding image quality and presence of imaging artefacts there was a significant difference between both coils (P<0.001) with the surface coil obtaining the better result. Conclusion: The use of the surface coil in the visualisation of the patellar cartilage can be recommended at knee MR.

  7. Immunogenicity of coiled-coil based drug-free macromolecular therapeutics

    Czech Academy of Sciences Publication Activity Database

    Kverka, Miloslav; Hartley, J.M.; Chu, T.W.; Yang, J.; Heidchen, R.; Kopeček, J.

    2014-01-01

    Roč. 35, č. 2 (2014), s. 5886-5896 ISSN 1616-0177 R&D Projects: GA MŠk(CZ) EE2.3.30.0003 Grant - others:NIH(US) GM095606 Institutional support: RVO:61388971 Keywords : coiled-coil * enantiomers * HPMA copolymer Subject RIV: EC - Immunology

  8. The influence of fusion sequences on the thermal stabilities of coiled-coil proteins

    Czech Academy of Sciences Publication Activity Database

    Xu, C.; Joss, L.; Wang, C.; Pechar, Michal; Kopeček, J.

    2002-01-01

    Roč. 2, č. 8 (2002), s. 395-401 ISSN 1616-5187 R&D Projects: GA AV ČR KSK4055109 Grant - others:GA-(US) CA88047 Keywords : coiled -coil * fusion sequence * oligomers Subject RIV: CD - Macromolecular Chemistry Impact factor: 1.792, year: 2002

  9. Additional coiling of previously coiled cerebral aneurysms : Clinical and angiographic results

    NARCIS (Netherlands)

    Slob, MJ; Sluzewski, M; van Rooij, WJ; Roks, G; Rinkel, GJE

    BACKGROUND AND PURPOSE: Some cerebral aneurysms that have been coiled reopen over time and additional treatment should be considered to reduce the risk of recurrent hemorrhage. Our purpose was to assess procedural complications and angiographic results of additional coiling in patients with

  10. Advanced approaches for the characterization of a de novo designed antiparallel coiled coil peptide

    NARCIS (Netherlands)

    Pagel, K; Seeger, K; Seiwert, B; Villa, Alessandra; Mark, AE; Berger, S; Koksch, B

    2005-01-01

    We report here an advanced approach for the characterization of the folding pattern of a de novo designed antiparallel coiled coil peptide by high-resolution methods. Incorporation of two fluorescence labels at the C- and N-terminus of the peptide chain as well as modi. cation of two hydrophobic

  11. Associative diblock copolymers of poly(ethylene glycol) and coiled-coil peptides

    Czech Academy of Sciences Publication Activity Database

    Pechar, Michal; Kopečková, P.; Joss, L.; Kopeček, J.

    2002-01-01

    Roč. 2, č. 5 (2002), s. 199-206 ISSN 1616-5187 R&D Projects: GA AV ČR KSK4050111 Institutional research plan: CEZ:AV0Z4050913 Keywords : coiled -coil peptides * diblock copolymers * poly(ethylene glycol) Subject RIV: CD - Macromolecular Chemistry Impact factor: 1.792, year: 2002

  12. Structural Stability of the Coiled-Coil Domain of Tumor Susceptibility Gene (TSG)-101.

    Science.gov (United States)

    White, Jordan T; Toptygin, Dmitri; Cohen, Randy; Murphy, Natalie; Hilser, Vincent J

    2017-09-05

    The tumor susceptibility gene-101 coiled coil domain (TSG101cc) is an integral component of the endosomal maturation machinery and cytokinesis, and also interacts with several transcription factors. The TSG101cc has been crystallized as a homotetramer but is known to interact with two of its binding partners as a heterotrimer. To investigate this apparent discrepancy, we examined the solution thermodynamics of the TSG101cc. Here, we use circular dichroism, differential scanning calorimetry, analytical ultracentrifugation, fluorescence, and structural thermodynamic analysis to investigate the structural stability and the unfolding of the TSG101cc. We demonstrate that TSG101cc exists in solution primarily as a tetramer, which unfolds in a two-state manner. Surprisingly, no homodimeric or homotrimeric species were detected. Structural thermodynamic analysis of the homotetrameric structure and comparison with known oligomeric coiled-coils suggests that the TSG101cc homotetramer is comparatively unstable on a per residue basis. Furthermore, the homotrimeric coiled-coil is predicted to be much less stable than the functional heterotrimeric coiled-coil in the endosomal sorting complex required for transport 1 (ESCRT1). These results support a model whereby the tetramer-monomer equilibrium of TSG101 serves as the cellular reservoir of TSG101, which is effectively outcompeted when its binding partners are present and the heteroternary complex can form.

  13. Coiled-Coil Domains of SUN Proteins as Intrinsic Dynamic Regulators.

    Science.gov (United States)

    Nie, Si; Ke, Huimin; Gao, Feng; Ren, Jinqi; Wang, Mingzhu; Huo, Lin; Gong, Weimin; Feng, Wei

    2016-01-05

    SUN proteins are the core components of LINC complexes that span across the nuclear envelope for nuclear positioning and migration. SUN proteins contain at least one predicted coiled-coil domain preceding the SUN domain. Here, we found that the two coiled-coil domains (CC1 and CC2) of SUN2 exhibit distinct oligomeric states. CC2 is a monomer in solution. The structure of the CC2-SUN monomer revealed that CC2 unexpectedly folds as a three-helix bundle that interacts with the SUN domain and locks it in an inactive conformation. In contrast, CC1 is a trimer. The structure of the CC1 trimer demonstrated that CC1 is an imperfect coiled coil for the trimerization and activation of the SUN domain. Modulations of CC1 and CC2 dictate different oligomeric states of CC1-CC2-SUN, which is essential for LINC complex formation. Thus, the two coiled-coil domains of SUN2 act as the intrinsic dynamic regulators for controlling the SUN domain activity. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. The tripartite motif coiled-coil is an elongated antiparallel hairpin dimer

    Science.gov (United States)

    Sanchez, Jacint G.; Okreglicka, Katarzyna; Chandrasekaran, Viswanathan; Welker, Jordan M.; Sundquist, Wesley I.; Pornillos, Owen

    2014-01-01

    Tripartite motif (TRIM) proteins make up a large family of coiled-coil-containing RING E3 ligases that function in many cellular processes, particularly innate antiviral response pathways. Both dimerization and higher-order assembly are important elements of TRIM protein function, but the atomic details of TRIM tertiary and quaternary structure have not been fully understood. Here, we present crystallographic and biochemical analyses of the TRIM coiled-coil and show that TRIM proteins dimerize by forming interdigitating antiparallel helical hairpins that position the N-terminal catalytic RING domains at opposite ends of the dimer and the C-terminal substrate-binding domains at the center. The dimer core comprises an antiparallel coiled-coil with a distinctive, symmetric pattern of flanking heptad and central hendecad repeats that appear to be conserved across the entire TRIM family. Our studies reveal how the coiled-coil organizes TRIM25 to polyubiquitylate the RIG-I/viral RNA recognition complex and how dimers of the TRIM5α protein are arranged within hexagonal arrays that recognize the HIV-1 capsid lattice and restrict retroviral replication. PMID:24550273

  15. Golgi coiled-coil proteins contain multiple binding sites for Rab family G proteins

    NARCIS (Netherlands)

    Sinka, Rita; Gillingham, Alison K.; Kondylis, Vangelis; Munro, Sean

    2008-01-01

    Vesicles and other carriers destined for the Golgi apparatus must be guided to the correct cisternae. Golgins, long coiled-coil proteins that localize to particular Golgi subdomains via their C termini, are candidate regulators of vesicle sorting. In this study, we report that the GRIP domain

  16. Ohmic discharges in Tore Supra - Marfes and detached plasmas

    International Nuclear Information System (INIS)

    Vallet, J.C.

    1990-01-01

    The Tore Supra plasma characteristics are given. The observed discharges are either leaning on the graphite inner first wall or limited by movable pump limiters located outboard and at the bottom of the vacuum chamber. The particular plasma conditions which lead to marfes and detached plasmas in ohmically heated He and D2 discharges limited by the inner wall are investigated. The results show that the ratio of radiated power to ohmic power increase linearly with M.g. As M.g rises, attached plasma, marfe and detached plasma are sequentially observed. Detached plasma with an effective radius as small as. 7 times the limiter radius was observed on Tore Supra

  17. Shape Evolution of Detached Bridgman Crystals Grown in Microgravity

    Science.gov (United States)

    Volz, M. P.; Mazuruk, K.

    2015-01-01

    A theory describing the shape evolution of detached Bridgman crystals in microgravity has been developed. A starting crystal of initial radius r0 will evolve to one of the following states: Stable detached gap; Attachment to the crucible wall; Meniscus collapse. Only crystals where alpha plus omega is great than 180 degrees will achieve stable detached growth in microgravity. Results of the crystal shape evolution theory are consistent with predictions of the dynamic stability of crystallization (Tatarchenko, Shaped Crystal Growth, Kluwer, 1993). Tests of transient crystal evolution are planned for ICESAGE, a series of Ge and GeSi crystal growth experiments planned to be conducted on the International Space Station (ISS).

  18. The Nup62 Coiled-Coil Motif Provides Plasticity for Triple-Helix Bundle Formation.

    Science.gov (United States)

    Dewangan, Pravin S; Sonawane, Parshuram J; Chouksey, Ankita R; Chauhan, Radha

    2017-06-06

    The central transport channel of the vertebrate nuclear pore complex (NPC) consists of nucleoporins: Nup62, Nup54, and Nup58. The coiled-coil domains in α-helical regions of these nucleoporins are thought to be crucial for several protein-protein interactions in the NPC subcomplexes. In this study, we determined the crystal structure of the coiled-coil domain of rat Nup62 fragment (residues 362-425) to 2.4 Å resolution. The crystal structure shows the conserved coiled-coil domain as a parallel three-helix bundle for the Nup62(362-425) fragment. On the basis of our size exclusion chromatography coupled to multiangle light scattering analysis and glutaraldehyde cross-linking experiments, we conclude that the Nup62(362-425) fragment displays dynamic behavior in solution and can also exist in either homodimeric or homotrimeric states. Our comparative analysis of the rat Nup62(362-425) homotrimeric structure with previously reported heterotrimeric structures [rat Nup62(362-425)·Nup54(346-407) and Xenopus Nup62(358-485)·Nup54(315-450)·Nup58(283-406) complexes] demonstrates the structural basis for parallel triple-helix bundle formation for Nup62 with different partners. Moreover, we show that the coiled-coil domain of Nup62 is sufficient for interaction with the coiled-coil domain of rat Exo70, a protein in an exocyst complex. On the basis of these observations, we suggest the plausible chain replacement mechanism that yields to diverse protein assemblies with Nup62. In summary, the coiled-coil motif present in Nup62 imparts the ability to form a homotrimer and heterotrimers either with Nup54 or with Nup54-Nup58 within the NPCs as well as with Exo70 beyond the NPCs. These complexes of Nup62 suggest the crucial role of the coiled-coil motifs in providing plasticity to various modular assemblies.

  19. Vitrectomy, lensectomy and silicone oil tamponade in the management of retinal detachment associated with choroidal detachment

    Directory of Open Access Journals (Sweden)

    Jian-Di Liu

    2013-06-01

    Full Text Available AIM: To report the results of combined vitrectomy, lensectomy and silicone oil (SO tamponade in treating primary rhegmatogenous retinal detachment (RRD associated with choroidal detachment (CD.METHODS: A retrospective, consecutive and case series study of 21 subjects with concurrent RRD associated with CD was conducted. All subjects underwent a standard three-port 20G pars plana vitrectomy (PPV with lensectomy and silicone oil tamponade. Mean follow-up time was 8 months (rang from 4 to 19 months. The primary and final anatomic success rate, visual acuity and final intraocular pressure(IOP were recorded and analyzed.RESULTS: Of 21 subjects, 8 were women and 13 were men. Age at presentation ranged from 22 to 75 years (mean 57.4 years. The presenting vision ranged from light perception to 0.15. The initial IOP ranged from 3mmHg to 12mmHg (mean 6.2mmHg. All eyes were phakic except one pseudophakic. No intraocular lens was implanted during the primary surgical intervention. Fifteen of 21 (71.4% eyes had retina reattached after one operation. Six eyes had recurrent inferior retinal detachment due to proliferation. Five of them were successfully reattached after one or more additional operations. Mean IOP at final follow-up was 15.2mmHg (range from 8mmHg to 20mmHg. One case declined for further operation. The final reattachment rate was 95.2%. Visual acuity improved in 19 (90.5% eyes, was unchanged in 1 (4.8% eye and decreased in 1 (4.8% eye.CONCLUSION: Combination of vitrectomy, lensectomy and silicone tamponade is an effective method in treating RRD associated with CD, reducing the incidence of postoperative hypotony.

  20. Structural analysis (Siemens) of the Euratom coil for the large coil task

    International Nuclear Information System (INIS)

    Maurer, A.

    1981-01-01

    The structural analysis of coil and casing of large superconducting magnets is essential to ensure the safety in the design and is important for the concept of even larger magnet units in future projects. For the Large Coil Task calculations are performed by the finite element computer code NASTRAN to obtain the stress on the various structural parts under thermal and magnetic loads. The mechanical behavior of the coil and casing under normal as well as alternative load conditions is discussed. Plots demonstrate the state of deformation belonging to the single structure parts. The results for the components of normal and shear stresses in the coil as well as for the equivalent stresses in the casing are summarized. The finite element model used is presented. The assumptions relating to the material properties, the force transmitted between coil and casing, the loading conditions, and the boundary conditions are discussed. 2 refs

  1. Coil in coil - components for the high voltage superconducting resistive current limiter CULT 110

    Science.gov (United States)

    Elschner, S.; Stemmle, M.; Breuer, F.; Walter, H.; Frohne, C.; Noe, M.; Bock, J.

    2008-02-01

    The German government (BMBF/VDI) funded project CULT 110 is presently the largest European current limiter project and aims at the development of a one-phase resistive limiter for the voltage level of 110 kV. The contribution presents the actual state of development of the superconducting components. As in the successful predecessor project CURL 10 these are made of melt cast processed BSCCO 2212 bulk material, however monofilar instead of bifilar coils are used. The electrical protection concept is based on a normal conducting coil arranged around a superconducting coil and connected in parallel. Simultaneously this coil serves as an electrical bypass and, under fault conditions, generates a magnetic field for quench homogenisation. Since no continuously connected shunt is needed, a much higher voltage during faults can be applied. The rules for an optimum superconductor and coil design are given and the viability of the whole concept is demonstrated by both, experiment and numerical simulation.

  2. Molecular dynamics studies of PEGylated α-helical coiled coils and their self-assembled micelles.

    Science.gov (United States)

    Woo, Sun Young; Lee, Hwankyu

    2014-07-29

    We performed coarse-grained (CG) molecular dynamics simulations of trimeric α-helical coiled coils grafted with poly(ethylene glycol) (PEG) of different sizes and conjugate positions and the self-assembled micelle of amphiphilic trimers. The CG model for the trimeric coiled coil is verified by comparing the α-helical structure and interhelical distance with those calculated from all-atom simulations. In CG simulations of PEGylated trimers, the end-to-end distances and radii of gyration of PEGs grafted to the sides of peptides become shorter than those of free PEGs in water, which agrees with experiments. This shorter size of the grafted PEGs is also confirmed by calculating the thickness of the PEG layer, which is less than the size of the mushroom. These indicate the adsorption of PEG chains onto coiled coils since hydrophobic residues in the exterior sites of coiled coils tend to be less exposed to water and thus interact with PEGs, leading to the compact conformation of adsorbed PEGs. Simulations of the self-assembly of amphiphilic trimers show that the randomly distributed trimers self-assemble to micelles. The outer radius and hydrodynamic radius of the micelle, which were calculated respectively from radial densities and diffusion coefficients, are ∼7 nm, in agreement with the experimental value of ∼7.5 nm, while the aggregation number of amphiphilic molecules per micelle is lower than the experimentally proposed value. These simulations predict the experimentally measured size of PEGs grafted to the trimeric coiled coils and their self-assembled amphiphilic micelles and suggest that the aggregation number of the micelle may be lower, which needs to be confirmed by experiments.

  3. Automated de novo phasing and model building of coiled-coil proteins.

    Science.gov (United States)

    Rämisch, Sebastian; Lizatović, Robert; André, Ingemar

    2015-03-01

    Models generated by de novo structure prediction can be very useful starting points for molecular replacement for systems where suitable structural homologues cannot be readily identified. Protein-protein complexes and de novo-designed proteins are examples of systems that can be challenging to phase. In this study, the potential of de novo models of protein complexes for use as starting points for molecular replacement is investigated. The approach is demonstrated using homomeric coiled-coil proteins, which are excellent model systems for oligomeric systems. Despite the stereotypical fold of coiled coils, initial phase estimation can be difficult and many structures have to be solved with experimental phasing. A method was developed for automatic structure determination of homomeric coiled coils from X-ray diffraction data. In a benchmark set of 24 coiled coils, ranging from dimers to pentamers with resolutions down to 2.5 Å, 22 systems were automatically solved, 11 of which had previously been solved by experimental phasing. The generated models contained 71-103% of the residues present in the deposited structures, had the correct sequence and had free R values that deviated on average by 0.01 from those of the respective reference structures. The electron-density maps were of sufficient quality that only minor manual editing was necessary to produce final structures. The method, named CCsolve, combines methods for de novo structure prediction, initial phase estimation and automated model building into one pipeline. CCsolve is robust against errors in the initial models and can readily be modified to make use of alternative crystallographic software. The results demonstrate the feasibility of de novo phasing of protein-protein complexes, an approach that could also be employed for other small systems beyond coiled coils.

  4. Modulation of elasticity in functionally distinct domains of the tropomyosin coiled-coil.

    Science.gov (United States)

    Lakkaraju, Sirish Kaushik; Hwang, Wonmuk

    2009-03-01

    Alpha-helical coiled-coils are common protein structural motifs. Whereas vast information is available regarding their structure, folding, and stability, far less is known about their elastic properties, even though they play mechanical roles in many cases such as tropomyosin in muscle contraction or neck stalks of kinesin or myosin motor proteins. Using computer simulations, we characterized elastic properties of coiled-coils, either globally or locally. Global bending stiffness of standard leucine zipper coiled-coils was calculated using normal mode analysis. Mutations in hydrophobic residues involved in the knob-into-hole interface between the two alpha-helices affect elasticity significantly, whereas charged side chains forming inter-helical salt bridges do not. This suggests that coiled-coils with less regular heptad periodicity may have regional variations in flexibility. We show this by the flexibility map of tropomyosin, which was constructed by a local fluctuation analysis. Overall, flexibility varies by more than twofold and increases towards the C-terminal region of the molecule. Describing the coiled-coil as a twisted tape, it is generally more flexible in the splay bending than in the bending of the broad face. Actin binding sites in alpha zones show local rigidity minima. Broken core regions due to acidic residues at the hydrophobic face such as the Asp137 and the Glu218 are found to be the most labile with moduli for splay and broad face bending as 70 nm and 116 nm respectively. Such variation in flexibility could be relevant to the tropomyosin function, especially for moving across the non-uniform surface of F-actin to regulate myosin binding.

  5. Coil development for W VII-X

    International Nuclear Information System (INIS)

    Kisslinger, J.

    1988-01-01

    Starting from a closed vacuum flux surface near the edge and using the NESCOIL code, current distributions on various toroidal surfaces are obtained. The toroidal surfaces are optimized by varying the coefficients which describe the torus topology, and by restricting the number of coefficients for the potential distribution. Configuration HS4-12 with 4 field periods has 12 coils per field period, and that with 5 periods has 10 or 12 coils per period at an average coil aspect ratio of 5. Aspect ratio of the largest flux surfaces is 10. For Helias configurations with 5 field periods compared to those with 4 field periods, higher beta values are predicted. Keeping the coil aspect ratio constant the configuration with 5 field periods has coils with lower minimum curvature radius and a larger lateral excursion. They also have reduced distance between wall and plasma. To improve the geometrical tightness with 5 field periods an increase of the major radius from 5 to 6.5m and a reduction of Bo from 4 to 3T (which allows an increase of current density from 40 to 50 MA/m 2 ) is proposed

  6. Distal biceps rupture: the coil sign.

    Science.gov (United States)

    Austin, Luke; Pepe, Matt; VanBeek, Corinne; Tjoumakaris, Fotios

    2014-06-01

    Delayed repair of the distal biceps brachii tendon can lead to the formation of scar tissue and coiling of the tendon. Dissection of the scar tissue and unraveling of the tendon may allow for anatomic repair to the radial tuberosity. A 50-year-old man had a distal biceps brachii tendon tear with an intact lacertus fibrosis. Surgery was performed 22 days after injury. On inspection, the distal biceps tendon was coiled, encased in scar tissue, and unable to be reduced to the radial tuberosity. Dissection of the scar tissue and unraveling of the tendon provided additional length, allowing anatomic repair. Postoperatively, the patient regained full range of motion and strength and returned to work without restrictions. After a distal biceps brachii tear in which the lacertus fibrosis remains intact, the coiled tendon may become enveloped in a sheath of scar tissue. Dissection of the "pseudosheath" unveils the native tendon and allows reduction to the radial tuberosity. Cadaveric analysis shows that the pseudosheath may conceal 6 cm of coiled tendon. When the lacertus fibrosis remains intact after distal biceps tendon rupture, the tethered tendon stump may coil, become encased in scar tissue, and resemble the native tendon. Failure to identify the native tendon could result in the loss of 6 cm of tendon. Copyright 2014, SLACK Incorporated.

  7. Extrap with iron-cored coils

    International Nuclear Information System (INIS)

    Lehnert, B.

    1985-05-01

    In Extrap configurations there is a high average beta value with respect to the plasma confinement volume. The externally imposed magnetic field which is required for stabilization therefore comes out to have a rather moderate strength, even under expected reactor conditions. As a consequence, this field can be generated not only by conventional external conductor arrangements, but also by iron-cored coils being operated below the saturation limit. A proposal for such iron-cored coil systems is presented in this paper. As compared to conventional conductors, this has the advantage of localizing the magnetic energy of the externally imposed magnetic field mainly to the discharge vessel and the plasma volume, thereby increasing the engineering beta value substantially. Also the problems of the coil stresses and of irradiation of the coils appear to become simplified, as well as replacement of the coil system. A main limitation of this proposal is due to combination of iron core saturation with the required stabilization effect from an ion Larmor radius of sufficient relative magnitude. This limitaion requires further investigation, especially in the full-scale reactor case. Also the modifications of the field geometry by iron core shaping needs further analysis. (Author)

  8. Fabrication of the KSTAR toroidal field coil structure

    International Nuclear Information System (INIS)

    Choi, C.H.; Sa, J.W.; Park, H.K.; Hong, K.H.; Shin, H.; Kim, H.T.; Bak, J.S.; Lee, G.S.; Kwak, J.H.; Moon, H.G.; Yoon, H.H.; Lee, J.W.; Lee, S.K.; Song, J.Y.; Nam, K.M.; Byun, S.E.; Kim, H.C.; Ha, E.T.; Ahn, H.J.; Kim, D.S.; Lee, J.S.; Park, K.H.; Hong, C.D.

    2005-01-01

    The KSTAR toroidal field (TF) coil structure is under fabrication upon completion of engineering design and prototype construction. The prototype TF coil structure has been fabricated within allowable tolerances. Encasing of the prototype TF coil (TF00) in the prototype structure has been carried out through major processes involving a coil encasing, an enclosing weld, a vacuum pressure impregnation, and an outer surface machining. During the enclosing weld of the TF00 coil structure, we have measured temperatures and stresses on the coil surface. Assembly test had been performed with the TF00 coil structure. We have chosen Type 316LN as material of the TF coil structure. We used the narrow-gap TIG welding method. Doosan Heavy Industries and Construction Company (DHI) will complete the fabrication of the TF coil structure in Feb. 2006. (author)

  9. Improving Coil Designs for the HSX Stellarator with FOCUS

    Science.gov (United States)

    Kruger, Thomas; Zhu, Caoxiang; Bader, Aaron; Singh, Luquant; Anderson, David

    2017-10-01

    We use the FOCUS code to generate improved coil sets for the HSX stellarator. FOCUS produces curves in 3D space to best reproduce a target plasma equilibrium. Unlike similar codes, the curves in FOCUS are not constrained to lie on a user-defined 2D surface. Therefore FOCUS can inherently solve problems such as determining the optimum coil-plasma distance for a given equilibrium. By adjusting the relative weights between a) the match to the plasma boundary, and b) the average coil length. We present the results from FOCUS where we attempt to improve the coil set by moving coils further away to reduce coil ripple, decreasing the number of coils to improve accessibility, and better matching the target plasma surface. We also present results of alternative coil designs with helical and saddle coils. Work supported by the US DOE under Grant DE-FG02-93ER54222 and UW Sorden account 233PRJ65ZM.

  10. The potential and need for energy saving in standard family detached and semi-detached wooden houses in arctic Greenland

    DEFF Research Database (Denmark)

    Bjarløv, Søren Peter; Vladyková, Petra

    2011-01-01

    The paper gives an account of the potential and need for energy saving in standard family detached and semi-detached wooden houses in Greenland. It is based on studies of house construction compared with Building Regulation requirements and the spread of buildings over time. In the climatic...... conditions of Greenland, there is considerable potential for energy saving in houses due to their construction, shape and condition. To estimate the total potential for energy saving and thus reducing CO2 emissions, we carried out a detailed investigation of three typical standard semi-detached family houses...

  11. Disappearance of a detached vapor mass in subcooled water

    International Nuclear Information System (INIS)

    Inada, Shigeaki; Miyasaka, Yoshiki; Izumi, Ryotaro.

    1986-01-01

    Experiments on pool transition boiling of water under atmospheric pressure on a heated surface 10 mm in diameter were conducted for subcooling 15 - 50 K. The mass flux of condensation of a detached coalescent vapor bubble was experimentally estimated by a mathematical model based on the mass transfer mechanism of condensation. As a result, it is clarified that the mass flux of condensation of the detached bubble was influenced by the initial growing velocity of a vapor bubble immediately following the detached bubble. The disappearance velocity of the detached bubble defined as a ratio of the bubble diameter at the departure to the time required until the disappearance, is in the range 0.2 to 2.0 m/sec. The disappearance velocity is proportional to the initial growing velocity of the bubble, to the square of the heat flux of the heated surface and to the cube of the wall superheat, separately. (author)

  12. Method of detaching adherent cells for flow cytometry

    KAUST Repository

    Kaur, Mandeep

    2015-12-24

    In one aspect, a method for detaching adherent cells can include adding a cell lifting solution to the media including a sample of adherent cells and incubating the sample of adherent cells with the cell lifting solution. No scraping or pipetting is needed to facilitate cell detachment. The method do not require inactivation of cell lifting solution and no washing of detaching cells is required to remove cell lifting solution. Detached cells can be stained with dye in the presence of cell lifting solution and are further analyzed using flow cytometer. The method has been tested using 6 different cell lines, 4 different assays, two different plate formats (96 and 384 well plates) and two different flow cytometry instruments. The method is simple to perform, less time consuming, with no cell loss and makes high throughput flow cytometry on adherent cells a reality.

  13. Tracing detached and attached care practices in nursing education

    DEFF Research Database (Denmark)

    Soffer, Ann Katrine B.

    2014-01-01

    of care are not explicated in the curriculum or textbooks; however, they surfaced once this crooked approach to studying care in a simulated practice was applied. The article starts from the assertion that detached engagements are not recognized within the field of nursing education as an equal component...... to attachments. Yet empirical cases from the skills lab and hospitals illustrate how students sometimes felt emotionally attached to plastic dummies and how experienced nurses sometimes practised a degree of detachment in relation to human patients. Detached engagements will therefore be presented as part......The implementation of skills labs in Danish nursing education can, in itself, be viewed as a complexity. The students are expected to eventually carry out their work in a situated hospital practice, but they learn their professional skills in a different space altogether, detached and removed from...

  14. Serous retinal detachment after trabeculectomy in angle recession glaucoma

    Directory of Open Access Journals (Sweden)

    Roy, Avik Kumar

    2015-12-01

    Full Text Available An 18-year-old male with 360 degree angle recession after blunt trauma in his right eye developed uncontrolled intraocular pressure (IOP despite four antiglaucoma medications (AGM with advancing disc damage. He underwent trabeculectomy with intraoperative mitomycin-c (MMC application. There was an intraoperative vitreous prolapse which was managed accordingly. On post-surgery day 1, he had shallow choroidal detachment superiorly with non-recordable IOP. This was deteriorated 1 week postoperatively as choroidal detachment proceeded to serous retinal detachment. He was started with systemic steroid in addition to topical route. The serous effusions subsided within 2 weeks time. At the last follow up at 3 months, he was enjoying good visual acuity, deep anterior chamber, diffuse bleb, an IOP in low teens off any AGM and attached retina. This case highlights the rare occurrence of serous retinal detachment after surgical management of angle recession glaucoma.

  15. Fluid–rock interaction across the South Tibetan Detachment ...

    Indian Academy of Sciences (India)

    scale normal fault system called the South Tibetan Detachment (STD). A mineralogical, geochemical and fluid inclusion study of samples from the fault zone of the Malari Granite was performed to reveal the imprints of fluid–rock interaction.

  16. Scleral buckling for retinal detachment in patients with retinoblastoma

    International Nuclear Information System (INIS)

    Buzney, S.M.; Pruett, R.C.; Regan, C.D.; Walton, D.S.; Smith, T.R.

    1984-01-01

    Three children (two girls and one boy) with bilateral retinoblastoma each developed a presumed rhegmatogenous retinal detachment in one eye. All three eyes had previously received radiation and cryotherapy. In each case the retinal detachment responded promptly to conventional surgical methods via scleral buckling in the area of treated retinoblastoma and presumed retinal break. All three eyes have retained useful vision for follow-up periods of 3.5 to 12 years

  17. Scleral buckling for retinal detachment in patients with retinoblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Buzney, S.M.; Pruett, R.C.; Regan, C.D.; Walton, D.S.; Smith, T.R.

    1984-10-15

    Three children (two girls and one boy) with bilateral retinoblastoma each developed a presumed rhegmatogenous retinal detachment in one eye. All three eyes had previously received radiation and cryotherapy. In each case the retinal detachment responded promptly to conventional surgical methods via scleral buckling in the area of treated retinoblastoma and presumed retinal break. All three eyes have retained useful vision for follow-up periods of 3.5 to 12 years.

  18. Retinal Detachment due to CrossFit Training Injury

    Directory of Open Access Journals (Sweden)

    Stephanie A. Joondeph

    2013-01-01

    Full Text Available The purpose of this paper is to describe a traumatic retinal detachment occurring as a result of CrossFit training using an elastic exercise band. The patient sustained an ocular injury from an elastic band during CrossFit training, resulting in a giant retinal dialysis and retinal detachment, which were successfully repaired. Trainers and athletes need to be aware of the potential for ocular injury from elastic exercise bands and take appropriate precautions.

  19. Retinal Detachment due to CrossFit Training Injury.

    Science.gov (United States)

    Joondeph, Stephanie A; Joondeph, Brian C

    2013-01-01

    The purpose of this paper is to describe a traumatic retinal detachment occurring as a result of CrossFit training using an elastic exercise band. The patient sustained an ocular injury from an elastic band during CrossFit training, resulting in a giant retinal dialysis and retinal detachment, which were successfully repaired. Trainers and athletes need to be aware of the potential for ocular injury from elastic exercise bands and take appropriate precautions.

  20. Retinal Detachment due to CrossFit Training Injury

    OpenAIRE

    Joondeph, Stephanie A.; Joondeph, Brian C.

    2013-01-01

    The purpose of this paper is to describe a traumatic retinal detachment occurring as a result of CrossFit training using an elastic exercise band. The patient sustained an ocular injury from an elastic band during CrossFit training, resulting in a giant retinal dialysis and retinal detachment, which were successfully repaired. Trainers and athletes need to be aware of the potential for ocular injury from elastic exercise bands and take appropriate precautions.

  1. An analysis of the mechanical behaviour of a detaching retina.

    Science.gov (United States)

    Lakawicz, Joseph M; Bottega, William J; Prenner, Jonathan L; Fine, Howard F

    2015-06-01

    An improved solution to the mechanics-based mathematical model for retinal detachment developed by Bottega et al. (2013, Math. Med. Biol., 30, 287-310) is found by removing the simplifying assumption of negligible meridian displacement employed in that study. The model considers retinas with and without central tears and takes contraction of the vitreous and extension of its fibrils, along with a pressure difference across the retina, as the impetus for detachment propagation. Exact analytical solutions are established for the meridian and radial displacements of detaching retinas with and without tears, and numerical simulations are performed based on these solutions. Inclusion of the meridian displacements is seen to result in substantially larger radial displacements without affecting the 'dimpling' behaviour of the detaching retina observed previously. However, the critical stress for detachment propagation is substantially decreased by the inclusion of the meridian displacement. The effects of changes in material and geometric parameters, as well as the influence of the presence and size of the retinal tear on detachment propagation are also studied. The model predicts that retinal detachment propagates catastrophically, which is in agreement with the results found by Bottega et al. (2013, Math. Med. Biol., 30, 287-310) and also with clinical observations. Results show that the inclusion of the meridian displacements enhances the previously seen stabilizing effect a retinal tear can have with regard to detachment propagation. The meridian displacement is similarly seen to enhance the influence that the size of the tear has on this effect. © The Authors 2014. Published by Oxford University Press on behalf of the Institute of Mathematics and its Applications. All rights reserved.

  2. An Unusual Case of Extensive Lattice Degeneration and Retinal Detachment

    OpenAIRE

    Mathew, David J.; Sarma, Saurabh Kumar; Basaiawmoit, Jennifer V.

    2016-01-01

    Lattice degeneration of the retina is not infrequently encountered on a dilated retinal examination and many of them do not need any intervention. We report a case of atypical lattice degeneration variant with peripheral retinal detachment. An asymptomatic 35-year-old lady with minimal refractive error was found to have extensive lattice degeneration, peripheral retinal detachment and fibrotic changes peripherally with elevation of retinal vessels on dilated retinal examination. There were al...

  3. CS model coil experimental log book

    Energy Technology Data Exchange (ETDEWEB)

    Nishijima, Gen; Sugimoto, Makoto; Nunoya, Yoshihiko; Wakabayashi, Hiroshi; Tsuji, Hiroshi [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment

    2001-02-01

    Charging test of the ITER CS Model Coil which is the world's largest superconducting pulse coil and the CS Insert Coil had started at April 11, 2000 and had completed at August 18, 2000. In the campaign, total shot numbers were 356 and the size of the data file in the DAS (Data Acquisition System) was over 20 GB. This report is a database that consists of the log list and the log sheets of every shot. One can access the database, make a search, and browse results via Internet (http://1ogwww.naka.jaeri.go.jp). The database will be useful to quick search to choose necessary shots. (author)

  4. Acoustic rainbow trapping by coiling up space

    KAUST Repository

    Ni, Xu

    2014-11-13

    We numerically realize the acoustic rainbow trapping effect by tapping an air waveguide with space-coiling metamaterials. Due to the high refractive-index of the space-coiling metamaterials, our device is more compact compared to the reported trapped-rainbow devices. A numerical model utilizing effective parameters is also calculated, whose results are consistent well with the direct numerical simulation of space-coiling structure. Moreover, such device with the capability of dropping different frequency components of a broadband incident temporal acoustic signal into different channels can function as an acoustic wavelength division de-multiplexer. These results may have potential applications in acoustic device design such as an acoustic filter and an artificial cochlea.

  5. Considerations against a force compensated coil

    International Nuclear Information System (INIS)

    Hassenzahl, W.

    1988-08-01

    The cost of structural components in a large superconducting coil may well exceed the coil and cryostat cost. As a result, the idea of constructing a system composed of two different coil types assembled in such a way that the sources balance and reduce the total structural requirement is oft proposed. A suitable geometry has never been found for the fundamental reason that there can be no force compensated solution. In this paper, the general problem is presented and an analysis of the energy stored and stresses produced in the structure are described in a fundamental way. Finally, the relation between structural mass M and stored energy E, M ≥/rho/E/σ/sub w/, that is valid for all magnetic systems is developed, where /rho/ is the density of the structure and σ/sub w/ is the working stress in the structure. 12 refs., 2 figs

  6. Determination of Coil Inductances Cylindrical Iron Nucleus

    Directory of Open Access Journals (Sweden)

    Azeddine Mazouz

    2014-03-01

    Full Text Available The paper describes the investigation and development of a structure and performance characteristics of a coil iron nucleus cylindrical (C.I.N.C. The coil iron nucleus cylindrical is a nonlinear electro radio in which the moving of the nucleus in a sense or in other causes change in inductance and can reach extreme values at the superposition of nucleus and coil centers. The variation of the inductance and the degree of freedom of movement of the nucleus can lead to a device with electromechanical conversion The aim of this paper is the determination and visualization of self inductance and mutual of the (C.I.N.C based on geometric dimensions and the displacement of the nucleus.  

  7. [Prevention of retinal detachment and treatment of retinoschisis].

    Science.gov (United States)

    Messmer, E P

    1990-01-01

    The necessity for prophylactic treatment for degenerative disease in the peripheral retina cannot be evaluated merely on the basis of the ophthalmoscopic findings. Factors such as the patient's history, refraction, the status of the vitreous, and prospective future cataract extraction all have a major impact on the risk of developing retinal detachment. The latter condition can be classified in to three groups: (1) low risk (patients with no history of retinal detachment, intraocular surgery or posterior vitreous detachment, myopia less than three diopters): treatment of atrophic holes and lattice degeneration is not justified, treatment of flap tears according to the circumstances; (2) medium risk (patients with no history of retinal or posterior vitreous detachment; however, myopia of more than three diopters and/or aphakia): the treatment of lattice degeneration is not justified; treatment of breaks according to the circumstances; (3) high risk: (patients with symptoms of posterior vitreous detachment): the treatment of lattice degeneration and atrophic holes is not justified: treatment of tears is necessary; fellow eyes: the treatment of retinal breaks is necessary; treatment of lattice degeneration seems advisable in cases with bilateral symmetric findings or prior to cataract extraction. Treatment of senile retinoschisis is only justified in cases with large and centrally located holes in the outer wall or in the presence of symptomatic schisis detachment.

  8. A new type of coil structure called pan-shaped coil of wireless charging system based on magnetic resonance

    Science.gov (United States)

    Yue, Z. K.; Liu, Z. Z.; Hou, Y. J.; Zeng, H.; Liang, L. H.; Cui, S.

    2017-11-01

    The problem that misalignment between the transmitting coil and the receiving coil significantly impairs the transmission power and efficiency of the system has been attached more and more attention. In order to improve the uniformity of the magnetic field between the two coils to solve this problem, a new type of coil called pan-shaped coil is proposed. Three-dimension simulation models of the planar-core coil and the pan-shaped coil are established using Ansoft Maxwell software. The coupling coefficient between the transmitting coil and the receiving coil is obtained by simulating the magnetic field with the receiving coil misalignment or not. And the maximum percentage difference strength along the radial direction which is defined as the magnetic field uniformity factor is calculated. According to the simulation results of the two kinds of coil structures, it is found that the new type of coil structure can obviously improve the uniformity of the magnetic field, coupling coefficient and power transmission properties between the transmitting coil and the receiving coil.

  9. Superconducting Coil Winding Machine Control System

    Energy Technology Data Exchange (ETDEWEB)

    Nogiec, J. M. [Fermilab; Kotelnikov, S. [Fermilab; Makulski, A. [Fermilab; Walbridge, D. [Fermilab; Trombly-Freytag, K. [Fermilab

    2016-10-05

    The Spirex coil winding machine is used at Fermilab to build coils for superconducting magnets. Recently this ma-chine was equipped with a new control system, which al-lows operation from both a computer and a portable remote control unit. This control system is distributed between three layers, implemented on a PC, real-time target, and FPGA, providing respectively HMI, operational logic and direct controls. The system controls motion of all mechan-ical components and regulates the cable tension. Safety is ensured by a failsafe, redundant system.

  10. Multiple coil closure of isolated aortopulmonary collateral

    Directory of Open Access Journals (Sweden)

    Padhi Sumanta

    2010-01-01

    Full Text Available A 7-month-old girl was diagnosed to have large aortopulmonary collateral during evaluation for congestive heart failure. There was no other evidence of cardiopulmonary disease. The collateral was successfully closed with multiple coils delivered sequentially. We describe the issues associated during closure of the aortopulmonary collateral in this case. To the best of our knowledge, this is the first reported case of large aortopulmonary collateral presenting with heart failure in an otherwise structurally normal heart that was closed successfully with multiple coils delivered sequentially.

  11. Self-assembling segmented coiled tubing

    Science.gov (United States)

    Raymond, David W.

    2016-09-27

    Self-assembling segmented coiled tubing is a concept that allows the strength of thick-wall rigid pipe, and the flexibility of thin-wall tubing, to be realized in a single design. The primary use is for a drillstring tubular, but it has potential for other applications requiring transmission of mechanical loads (forces and torques) through an initially coiled tubular. The concept uses a spring-loaded spherical `ball-and-socket` type joint to interconnect two or more short, rigid segments of pipe. Use of an optional snap ring allows the joint to be permanently made, in a `self-assembling` manner.

  12. Fine-tuning of protein domain boundary by minimizing potential coiled coil regions

    International Nuclear Information System (INIS)

    Iwaya, Naoko; Goda, Natsuko; Unzai, Satoru; Fujiwara, Kenichiro; Tanaka, Toshiki; Tomii, Kentaro; Tochio, Hidehito; Shirakawa, Masahiro; Hiroaki, Hidekazu

    2007-01-01

    Structural determination of individual protein domains isolated from multidomain proteins is a common approach in the post-genomic era. Novel and thus uncharacterized domains liberated from intact proteins often self-associate due to incorrectly defined domain boundaries. Self-association results in missing signals, poor signal dispersion and a low signal-to-noise ratio in 1 H- 15 N HSQC spectra. We have found that a putative, non-canonical coiled coil region close to a domain boundary can cause transient hydrophobic self-association and monomer-dimer equilibrium in solution. Here we propose a rational method to predict putative coiled coil regions adjacent to the globular core domain using the program COILS. Except for the amino acid sequence, no preexisting knowledge concerning the domain is required. A small number of mutant proteins with a minimized coiled coil region have been rationally designed and tested. The engineered domains exhibit decreased self-association as assessed by 1 H- 15 N HSQC spectra with improved peak dispersion and sharper cross peaks. Two successful examples of isolating novel N-terminal domains from AAA-ATPases are demonstrated. Our method is useful for the experimental determination of domain boundaries suited for structural genomics studies

  13. Fine-tuning of protein domain boundary by minimizing potential coiled coil regions.

    Science.gov (United States)

    Iwaya, Naoko; Goda, Natsuko; Unzai, Satoru; Fujiwara, Kenichiro; Tanaka, Toshiki; Tomii, Kentaro; Tochio, Hidehito; Shirakawa, Masahiro; Hiroaki, Hidekazu

    2007-01-01

    Structural determination of individual protein domains isolated from multidomain proteins is a common approach in the post-genomic era. Novel and thus uncharacterized domains liberated from intact proteins often self-associate due to incorrectly defined domain boundaries. Self-association results in missing signals, poor signal dispersion and a low signal-to-noise ratio in (1)H-(15)N HSQC spectra. We have found that a putative, non-canonical coiled coil region close to a domain boundary can cause transient hydrophobic self-association and monomer-dimer equilibrium in solution. Here we propose a rational method to predict putative coiled coil regions adjacent to the globular core domain using the program COILS. Except for the amino acid sequence, no preexisting knowledge concerning the domain is required. A small number of mutant proteins with a minimized coiled coil region have been rationally designed and tested. The engineered domains exhibit decreased self-association as assessed by (1)H-(15)N HSQC spectra with improved peak dispersion and sharper cross peaks. Two successful examples of isolating novel N-terminal domains from AAA-ATPases are demonstrated. Our method is useful for the experimental determination of domain boundaries suited for structural genomics studies.

  14. Strand Displacement in Coiled-Coil Structures: Controlled Induction and Reversal of Proximity.

    Science.gov (United States)

    Gröger, Katharina; Gavins, Georgina; Seitz, Oliver

    2017-11-06

    Coiled-coil peptides are frequently used to create new function upon the self-assembly of supramolecular complexes. A multitude of coil peptide sequences provides control over the specificity and stability of coiled-coil complexes. However, comparably little attention has been paid to the development of methods that allow the reversal of complex formation under non-denaturing conditions. Herein, we present a reversible two-state switching system. The process involves two peptide molecules for the formation of a size-mismatched coiled-coil duplex and a third, disruptor peptide that targets an overhanging end. A real-time fluorescence assay revealed that the proximity between two chromophores can be switched on and off, repetitively if desired. Showcasing the advantages provided by non-denaturing conditions, the method permitted control over the bivalent interactions of the tSH2 domain of Syk kinase with a phosphopeptide ligand. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Treatment of unruptured intracranial aneurysms using internally expanding coils

    Science.gov (United States)

    Suri, M. Fareed K.; Memon, Muhammad Zeeshan; Qureshi, Adnan I.

    2008-01-01

    Background and Purpose The International Subarachnoid Aneurysm Trial (ISAT) showed that patients with intracranial aneurysms treated with coil embolization have better clinical outcomes than those undergoing neurosurgical clipping. However some patients treated endovascularly have recurrence of aneurysms. Low packing density is often cited as a reason for recurrence. Coiling with hydrogel covered coils significantly improves the packing density. We report our initial experience in using a newly introduced design of hydrogel coils. Methods: Three consecutive patients with unruptured aneurysms were treated with hydrogel coated coils. During embolization, a stable framework was first established with bare metal coils, and gel coated coils were used subsequently to increase the packing density. After the procedure, packing density was estimated by calculating the compaction ratio using an online calculator. Results: Successful coil embolization was achieved in all 3 patients. Hydrogel coated coils comprised 11, 63 and 72% of the total coils deployed. One patient had coil herniation that required stent deployment. All patients remained neurologically intact during and after the procedure. Follow-up angiography in 2 patients at 6 months revealed aneurysm stability without any residual neck remnant. Conclusions: The softness of the hydrogel allowed us to deploy coated coils with good packing density. A slight expansion of these coils at the neck can be expected to reduce any neck remnant and potentially inhibit recurrence. PMID:22518218

  16. The fellow eye of patients with phakic rhegmatogenous retinal detachment from atrophic holes of lattice degeneration without posterior vitreous detachment.

    Science.gov (United States)

    Gonzales, C R; Gupta, A; Schwartz, S D; Kreiger, A E

    2004-11-01

    Primary phakic rhegmatogenous retinal detachment (RRD) without posterior vitreous detachment (PVD) represents a unique clinical entity that behaves differently from RRD associated with PVD. While previous studies have reported the long term findings in the fellow eye of patients with RRD and PVD, the outcome of the fellow eye of patients with RRD without PVD is not known. Consecutive patients with RRD not associated with PVD were studied retrospectively. The authors evaluated the fellow eye for retinal detachment or other vision threatening pathology. 27 patients (mean age 32 years) were studied with follow up of between 9 and 326 months (mean 111 months). 24 (89%) were myopic. Bilateral retinal detachment occurred in eight patients (30%). On initial examination, 17 patients (63%) had retinal findings (including lattice degeneration, atrophic holes, and/or cystic retinal tufts) in the fellow eye that might predispose them to retinal detachment. 14 vision threatening events or diagnoses occurred (nine of which were rhegmatogenous in nature) in the fellow eye including eight retinal detachments, one traumatic PVD without retinal tears, one retinal tear after PVD, one diagnosis of pigmentary glaucoma needing trabeculectomy, two visually significant cataracts, and one diagnosis of chorioretinitis. 23 patients (85%) maintained visual acuity better than 20/50, with most retaining 20/20 vision in the fellow eye. Patients who experience RRD without PVD are at risk of developing vision threatening events in the contralateral eye and, as such, the fellow eye should be followed carefully.

  17. Rogowski coils for studies of detonator initiation

    Science.gov (United States)

    Tasker, Douglas

    2017-06-01

    The Rogowski coil dates back to 1887 and it has commonly been employed to measure rapid changes of electrical currents without direct contact with the circuits, especially in high energy density applications. Recently, it has been used to measure currents in relatively low energy devices such as semiconductor circuits; here we report its utility in the analysis of detonator initiation. From an electrical perspective, the coil is essentially an air-cored transformer and measures the temporal rate of change of current dI/dt. Following a careful characterization of the circuit, an accurate measurement of this derivative is shown to provide a complete solution of the detonator circuit, including current, voltage, power and energy delivered to the detonator. The dependence of the electrical sensitivity, accuracy and bandwidth on coil design will be discussed and a new printed circuit design will be presented. Interesting features in the initiation of exploding bridgewire detonators have been observed with this coil and the results of various experiments will be discussed.

  18. Large coil test facility instrumentation system design

    International Nuclear Information System (INIS)

    Walstrom, P.L.; Fletcher, W.M.; Goddard, J.S.; Murphy, J.L.

    1979-01-01

    The design of the instrumentation system for the Large Coil Test Facility (LCTF) is described. Sensors are divided into two categories: coil diagnostic sensors, installed in the test coils; and facility sensors, installed in the various systems of the test facility in order to monitor their performance. After signal conditioning, data from the ''fast'' channels are multiplexed, digitized, and stored in four microcomputer systems programmed to be used in a ring buffer mode to record data before and after receipt of a random trigger from the normal zone detection circuitry. ''Slow'' channels are digitized by a scanner and buffered by a microcomputer. Selected data channels are continuously displayed on digital or recorded on strip chart recorders. The microcomputer systems are interfaced to a central minicomputer system for display and archival storage. Facility variables are digitized by a separate scanner system. Certain critical fault variables are compared with set point values, and if they are out of range, cause a programmable logic controller to initiate an emergency coil energy dump. 2 refs

  19. Voltage distribution within superconducting coils during quench

    International Nuclear Information System (INIS)

    Tominaka, T.; Hara, N.; Kuroda, K.

    1988-01-01

    A computer program which can be applied to the calculation of voltage distribution within superconducting coils during quench has been developed. The calculation is compared with an experiment for a small superconducting solenoid, and the propriety of the calculation is discussed

  20. Ureteral stents: coil strength and durometer.

    Science.gov (United States)

    Hendlin, Kari; Dockendorf, Kelly; Horn, Christina; Pshon, Nicole; Lund, Brynn; Monga, Manoj

    2006-07-01

    To evaluate the coil strength before and after urine exposure and the stiffness of commercially available double-J ureteral stents because both properties may affect stent performance and patient comfort. Twelve commercially available 6F ureteral stents were tested for coil strength before and after 30 days of urine exposure. The proximal end of each stent was inserted through a 2-mm hole in bologna, allowed to recoil, and then pulled using a handheld force gauge. Ten different commercially available ureteral stent models were tested for tensile strength using an MTS MicroBionix Testing System and Testworks II software and a 5 N load cell. The Cook Black Silicone and Cook C-Flex stents had the strongest coil strengths before urine exposure at 0.480 +/- 0.0 lb (P Circon Double J stent and Bard InLay. Ureteral stents can be differentiated according to their coil strength and stiffness. The impact of these properties on stent performance and patient comfort deserve additional evaluation. The significant variability found in stent stiffness among stents from different lot numbers suggests poor quality assurance in biomaterials or stent processing and increases the complexity of cross-stent comparisons.

  1. Moving coil linear variable differential transformer.

    Science.gov (United States)

    Ellis, J F; Walstrom, P L

    1978-03-01

    A moving-coil linear variable differential transformer with no ferromagnetic components is described. The device is essentially interchangeable with a conventional moving-core linear variable differential transformer, but is virtually unaffected by ambient magnetic fields up to 8 T. The transducer is connected to a standard commercially available carrier amplifier for signal conditioning.

  2. Testing electrical insulation of LCT coils and instrumentation

    International Nuclear Information System (INIS)

    Luton, J.N.; Ulbricht, A.R.; Ellis, J.F.; Shen, S.S.; Wilson, C.T.; Okuno, K.; Siewerdt, L.O.; Zahn, G.R.; Zichy, J.A.

    1986-09-01

    Three of the superconducting test coils in the Large Coil Task (LCT) use conductors cooled internally by forced flow of helium. In the other three coils, the conductors are cooled externally by a bath of helium. The coils and facility are designed for rapid discharges (dumps) at voltages up to 2.5 kV, depending on coil design. Many coil sensors are connected electrically to the conductors. These sensor leads and signal conditioning equipment also experience high voltage. High-potential tests of ground insulation were performed on all components of the International Fusion Superconducting Magnet Test Facility (IFSMTF). Coil insulation was also tested by ring-down tests that produced voltage distributions within the coils like those occurring during rapid discharge. Methods were developed to localize problem areas and to eliminate them. The effect on breakdown voltage near the Paschen minimum of magnetic fields up to 2 T was investigated

  3. Superconducting coil design for a tokamak experimental power reactor

    International Nuclear Information System (INIS)

    Turner, L.R.; Wang, S.T.; Smelser, P.

    1977-01-01

    Superconducting toroidal field (TF) and polodial-field (PF) coils have been designed for the proposed Argonne National Laboratory experimental power reactor (EPR). Features of the design include: (1) Peak field of 8 T at 4.2 K or 10 T at 3.0 K. (2) Constant-tension shape for the TF coils, corrected for the finite number (16) of coils. (3) Analysis of errors in coil alignment. (4) Comparison of safety aspects of series-connected and parallel-connected coils. (5) A 60 kA sheet conductor of NbTi with copper stabilizer and stainless steel for support. (6) Superconducting PF coils outside the TF coils. (7) The TF coils shielded from pulsed fields by high-purity aluminum

  4. Structural design of the superconducting toroidal field coils for ITER

    International Nuclear Information System (INIS)

    Wong, F.M.G.; Sborchia, C.; Thome, R.J.; Malkov, A.; Titus, P.H.

    1995-01-01

    Structural design issues and features of the superconducting toroidal field (TF) coils for the International Thermonuclear Experimental Reactor (ITER) will be discussed. Selected analyses of the structural and mechanical behavior of the ITER TF coils will also be presented. (orig.)

  5. A Chick Model of Retinal Detachment: Cone Rich and Novel

    Science.gov (United States)

    Cebulla, Colleen M.; Zelinka, Chris P.; Scott, Melissa A.; Lubow, Martin; Bingham, Amanda; Rasiah, Stephen; Mahmoud, Ashraf M.; Fischer, Andy J.

    2012-01-01

    Background Development of retinal detachment models in small animals can be difficult and expensive. Here we create and characterize a novel, cone-rich retinal detachment (RD) model in the chick. Methodology/Principal Findings Retinal detachments were created in chicks between postnatal days 7 and 21 by subretinal injections of either saline (SA) or hyaluronic acid (HA). Injections were performed through a dilated pupil with observation via surgical microscope, using the fellow eye as a control. Immunohistochemical analyses were performed at days 1, 3, 7, 10 and 14 after retinal detachment to evaluate the cellular responses of photoreceptors, Müller glia, microglia and nonastrocytic inner retinal glia (NIRG). Cell proliferation was detected with bromodeoxyuridine (BrdU)-incorporation and by the expression of proliferating cell nuclear antigen (PCNA). Cell death was detected with terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL). As in mammalian models of RD, there is shortening of photoreceptor outer segments and mis-trafficking of photoreceptor opsins in areas of RD. Photoreceptor cell death was maximal 1 day after RD, but continued until 14 days after RD. Müller glia up-regulated glial fibriliary acidic protein (GFAP), proliferated, showed interkinetic nuclear migration, and migrated to the subretinal space in areas of detachment. Microglia became reactive; they up-regulated CD45, acquired amoeboid morphology, and migrated toward outer retina in areas of RD. Reactive NIRG cells accumulated in detached areas. Conclusions/Significance Subretinal injections of SA or HA in the chick eye successfully produced retinal detachments and cellular responses similar to those seen in standard mammalian models. Given the relatively large eye size, and considering the low cost, the chick model of RD offers advantages for high-throughput studies. PMID:22970190

  6. Cost-Utility of Evaluation for Posterior Vitreous Detachment and Prophylaxis of Retinal Detachment.

    Science.gov (United States)

    Yannuzzi, Nicolas A; Chang, Jonathan S; Brown, Gary C; Smiddy, William E

    2018-01-01

    To evaluate the costs and cost-utility of examination for posterior vitreous detachment (PVD) and treatment of associated pathology, and of managing various other peripheral retinal disorders to prevent retinal detachment (RD). A decision analysis model of cost-utility. There were no participants. Published retrospective data on the natural course of PVD, retinal tears, and lattice degeneration were used to quantitate the visual benefits of examination and treatment. Center for Medicare and Medicaid Services data were used to calculate associated modeled costs in a hospital/facility-based and nonfacility/ambulatory surgical center (ASC)-based setting. Published standards of utility for a given level of visual acuity were used to derive costs and quality-adjusted life years (QALYs). Cost of evaluation and treatment, utility of defined health states, QALY, and cost per QALY. The modeled cost of evaluation of a patient with PVD and treatment of associated pathology in the facility/hospital (nonfacility/ASC)-based setting was $65 to $190 ($25-$71) depending on whether a single or 2-examination protocol was used. The cost per QALY saved was $255 to $638/QALY ($100-$239/QALY). Treatment of a symptomatic horseshoe tear resulted in a net cost savings of $1749 ($1314) and improved utility, whereas treatment of an asymptomatic horseshoe tear resulted in $2981/QALY ($1436/QALY). Treatment of asymptomatic lattice degeneration in an eye in which the fellow eye had a history of RD resulted in $4414/QALY ($2187/QALY). Evaluation and management of incident acute PVD (and symptomatic horseshoe tears) offer a low cost and a favorable cost-utility (low $/QALY) as a result of the minimization of the cost and morbidity associated with the development of RD, thus justifying current practice standards. Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  7. Coiled-Coil Irregularities and Instabilities in Group A Streptococcus M1 Are Required for Virulence

    Energy Technology Data Exchange (ETDEWEB)

    McNamara, Case; Zinkernagel, Annelies S.; Macheboeuf, Pauline; Cunningham, Madeleine W.; Nizet, Victor; Ghosh, Partho (UO-HSC); (UCSD)

    2008-07-21

    Antigenically variable M proteins are major virulence factors and immunogens of the human pathogen group A Streptococcus (GAS). Here, we report the -3 angstrom resolution structure of a GAS M1 fragment containing the regions responsible for eliciting type-specific, protective immunity and for binding fibrinogen, which promotes M1 proinflammatory and antiphagocytic functions. The structure revealed substantial irregularities and instabilities throughout the coiled coil of the M1 fragment. Similar structural irregularities occur in myosin and tropomyosin, explaining the patterns of cross-reactivity seen in autoimmune sequelae of GAS infection. Sequence idealization of a large segment of the M1 coiled coil enhanced stability but diminished fibrinogen binding, proinflammatory effects, and antibody cross-reactivity, whereas it left protective immunogenicity undiminished. Idealized M proteins appear to have promise as vaccine immunogens.

  8. Self-sustained detachment observed in LHD and comparison with detachment and Marfe in W7-AS

    Energy Technology Data Exchange (ETDEWEB)

    Miyazawa, J.; Masuzaki, S.; Yamada, H.; Sakamoto, R.; Peterson, B. J.; Shoji, M.; Ohyabu, N.; Komori, A.; Motojima, O.

    2005-07-01

    One of the crucial issues for a magnetically confined fusion reactor [1-3] is the reduction of the divertor heat load. Edge plasma cooling by increasing the density or introducing impurities such as neon as radiators is effective for reducing the divertor heat load by detaching the plasma from the divertor plates. In high-density tokamak plasmas, the so-called high-recycling regime is predicted by two-point model [4,5], where the divertor temperature (density) nonlinearly decreases (increases) with the main plasma density. Detachment takes place when the density is increased further. Then, the pressure in the flux tube is no longer conserved due to the increased radiation loss, charge exchange loss, and volume recombination. Eventually, the discharge is terminated by disruption often via rapid formation of a radiation condensation Marfe [5,6]. This scenario well explains the experimental results of tokamaks [5,7]. A similar kind of conventional detachment has been also intensively studied in a stellarator, W7-AS, after modification to the island divertor configuration [8,9]. Detachment in W7-AS is achieved by increasing the density beyond the density threshold for the high-density H-mode (HDH) [10]. As the density is increased further to the operational density limit, complete detachment takes place and, in some cases, the Marfe is formed on (or inside of) the last-closed-flux-surface (LCFS) [11-13]. These are reviewed in Section 4. Recently, a new state of self-sustained detachment has been found in LHD and named the Serpens mode (Self-regulated plasma edge neath the last-closed-flux-surface) [15,16]. In the Serpens mode, the hot plasma boundary is shrinking to equal 90 % of the LCFS radius. Large fluctuations appear in the divertor flux, H alpha and Cm signals, together with a rotating radiation belt named the serpent [17]. Detachment in LHD is observed in a significant decrease in the ion saturation current, Isat, measured on the divertor tiles [18,19]. In this

  9. Absolute Ethanol Embolisation of Mandibular Arteriovenous Malformations Following Direct Percutaneous Puncture and Release of Coils via a Microcatheter.

    Science.gov (United States)

    Wang, D; Su, L; Han, Y; Wang, Z; Zheng, L; Fan, X

    2017-06-01

    To evaluate the safety, efficacy, and medium-term outcome of a modified technique of ethanol embolisation of mandibular arteriovenous malformations (AVMs) following a direct percutaneous transvenous approach to the release of coils via a microcatheter. From January 2012 to July 2014, 18 consecutive patients (mean age 20.9 years [range 10-35 years]) with symptomatic AVMs of the mandible were enrolled. A microcatheter was inserted into the lesion via a direct percutaneous puncture needle. Electrolytically detachable coils and 0.018 mm coils were super-selectively placed to decrease the flow and volume of the arteriovenous fistulas via a microcatheter. Absolute ethanol was injected to obliterate the fistulas. Clinical follow-up was performed in all patients. Therapeutic outcomes were determined by evaluating the degree of devascularisation at follow-up angiography and symptoms and signs. Transvenous release of coils combined with absolute ethanol embolisation were used in all cases. The amount of ethanol used ranged from 5 to 50 mL (mean 25.7 mL) in a single session. Sixteen of 18 patients were cured, and two had partial remission. Follow-up times ranged from 8 to 26 months (medium 15.7 months), and there was no angiographic recurrence of the lesions. Minor complication occurred in five of the 18 patients. There were no major complications. Absolute ethanol embolisation following a direct percutaneous transvenous approach to release coils via a microcatheter is a feasible, safe, and highly effective method for the management of mandibular AVMs. Copyright © 2017 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  10. GBNV encoded movement protein (NSm) remodels ER network via C-terminal coiled coil domain

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Pratibha; Savithri, H.S., E-mail: bchss@biochem.iisc.ernet.in

    2015-08-15

    Plant viruses exploit the host machinery for targeting the viral genome–movement protein complex to plasmodesmata (PD). The mechanism by which the non-structural protein m (NSm) of Groundnut bud necrosis virus (GBNV) is targeted to PD was investigated using Agrobacterium mediated transient expression of NSm and its fusion proteins in Nicotiana benthamiana. GFP:NSm formed punctuate structures that colocalized with mCherry:plasmodesmata localized protein 1a (PDLP 1a) confirming that GBNV NSm localizes to PD. Unlike in other movement proteins, the C-terminal coiled coil domain of GBNV NSm was shown to be involved in the localization of NSm to PD, as deletion of this domain resulted in the cytoplasmic localization of NSm. Treatment with Brefeldin A demonstrated the role of ER in targeting GFP NSm to PD. Furthermore, mCherry:NSm co-localized with ER–GFP (endoplasmic reticulum targeting peptide (HDEL peptide fused with GFP). Co-expression of NSm with ER–GFP showed that the ER-network was transformed into vesicles indicating that NSm interacts with ER and remodels it. Mutations in the conserved hydrophobic region of NSm (residues 130–138) did not abolish the formation of vesicles. Additionally, the conserved prolines at positions 140 and 142 were found to be essential for targeting the vesicles to the cell membrane. Further, systematic deletion of amino acid residues from N- and C-terminus demonstrated that N-terminal 203 amino acids are dispensable for the vesicle formation. On the other hand, the C-terminal coiled coil domain when expressed alone could also form vesicles. These results suggest that GBNV NSm remodels the ER network by forming vesicles via its interaction through the C-terminal coiled coil domain. Interestingly, NSm interacts with NP in vitro and coexpression of these two proteins in planta resulted in the relocalization of NP to PD and this relocalization was abolished when the N-terminal unfolded region of NSm was deleted. Thus, the NSm

  11. Compressing DNA sequence databases with coil

    Directory of Open Access Journals (Sweden)

    Hendy Michael D

    2008-05-01

    Full Text Available Abstract Background Publicly available DNA sequence databases such as GenBank are large, and are growing at an exponential rate. The sheer volume of data being dealt with presents serious storage and data communications problems. Currently, sequence data is usually kept in large "flat files," which are then compressed using standard Lempel-Ziv (gzip compression – an approach which rarely achieves good compression ratios. While much research has been done on compressing individual DNA sequences, surprisingly little has focused on the compression of entire databases of such sequences. In this study we introduce the sequence database compression software coil. Results We have designed and implemented a portable software package, coil, for compressing and decompressing DNA sequence databases based on the idea of edit-tree coding. coil is geared towards achieving high compression ratios at the expense of execution time and memory usage during compression – the compression time represents a "one-off investment" whose cost is quickly amortised if the resulting compressed file is transmitted many times. Decompression requires little memory and is extremely fast. We demonstrate a 5% improvement in compression ratio over state-of-the-art general-purpose compression tools for a large GenBank database file containing Expressed Sequence Tag (EST data. Finally, coil can efficiently encode incremental additions to a sequence database. Conclusion coil presents a compelling alternative to conventional compression of flat files for the storage and distribution of DNA sequence databases having a narrow distribution of sequence lengths, such as EST data. Increasing compression levels for databases having a wide distribution of sequence lengths is a direction for future work.

  12. Coiled-coil forming peptides for the induction of silver nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Božič Abram, Sabina [Department of Synthetic Biology and Immunology, National Institute of Chemistry, Hajdrihova 19, 1000 Ljubljana (Slovenia); Graduate School of Biomedicine, University of Ljubljana, Ljubljana 1000 (Slovenia); Aupič, Jana [Department of Synthetic Biology and Immunology, National Institute of Chemistry, Hajdrihova 19, 1000 Ljubljana (Slovenia); Doctoral Programme in Chemical Sciences, Faculty of Chemistry and Chemical Technology, University of Ljubljana, Ljubljana 1000 (Slovenia); Dražić, Goran [Laboratory for Materials Chemistry, National Institute of Chemistry, Hajdrihova 19, 1000 Ljubljana (Slovenia); Gradišar, Helena [Department of Synthetic Biology and Immunology, National Institute of Chemistry, Hajdrihova 19, 1000 Ljubljana (Slovenia); EN-FIST, Centre of Excellence, Trg Osvobodilne fronte 13, Ljubljana 1000 (Slovenia); Jerala, Roman, E-mail: roman.jerala@ki.si [Department of Synthetic Biology and Immunology, National Institute of Chemistry, Hajdrihova 19, 1000 Ljubljana (Slovenia); EN-FIST, Centre of Excellence, Trg Osvobodilne fronte 13, Ljubljana 1000 (Slovenia)

    2016-04-08

    Biopolymers with defined sequence patterns offer an attractive alternative for the formation of silver nanoparticle (AgNP). A set of coiled-coil dimer forming peptides was tested for their AgNP formation ability. Seventeen of those peptides mediated the formation of AgNPs in aqueous solution at neutral pH, while the formation of a coiled-coil dimer inhibited the nanoparticle generation. A QSAR regression model on the relationship between sequence and function suggests that in this peptide type the patterns KXQQ and KXEE are favorable, whereas Ala residues appear to have an inhibitory effect. UV–VIS spectra of the obtained nanoparticles gave a peak at around 420 nm, typical for AgNPs in the size range around 40 nm, which was confirmed by dynamic light scattering and transmission electron microscopy. Peptide-induced AgNPs exhibited good antibacterial activity, even after a 15 min contact time, while they had low toxicity to human cells at the same concentrations. These results show that our designed peptides generate AgNPs with antibacterial activity at mild conditions and might be used for antibacterial coatings. - Highlights: • 17 of the 30 tested coiled-coil forming peptides induce AgNP formation. • Coiled-coil dimer formation suppresses AgNP generation of individual peptides. • Size of the peptide-induced silver nanoparticles is around 40 nm. • QSAR analysis points to the importance of KXQQ and KXEE motifs for AgNP generation. • Peptide-induced silver nanoparticles exhibit antibacterial activity.

  13. CCBuilder 2.0: Powerful and accessible coiled-coil modeling.

    Science.gov (United States)

    Wood, Christopher W; Woolfson, Derek N

    2018-01-01

    The increased availability of user-friendly and accessible computational tools for biomolecular modeling would expand the reach and application of biomolecular engineering and design. For protein modeling, one key challenge is to reduce the complexities of 3D protein folds to sets of parametric equations that nonetheless capture the salient features of these structures accurately. At present, this is possible for a subset of proteins, namely, repeat proteins. The α-helical coiled coil provides one such example, which represents ≈ 3-5% of all known protein-encoding regions of DNA. Coiled coils are bundles of α helices that can be described by a small set of structural parameters. Here we describe how this parametric description can be implemented in an easy-to-use web application, called CCBuilder 2.0, for modeling and optimizing both α-helical coiled coils and polyproline-based collagen triple helices. This has many applications from providing models to aid molecular replacement for X-ray crystallography, in silico model building and engineering of natural and designed protein assemblies, and through to the creation of completely de novo "dark matter" protein structures. CCBuilder 2.0 is available as a web-based application, the code for which is open-source and can be downloaded freely. http://coiledcoils.chm.bris.ac.uk/ccbuilder2. We have created CCBuilder 2.0, an easy to use web-based application that can model structures for a whole class of proteins, the α-helical coiled coil, which is estimated to account for 3-5% of all proteins in nature. CCBuilder 2.0 will be of use to a large number of protein scientists engaged in fundamental studies, such as protein structure determination, through to more-applied research including designing and engineering novel proteins that have potential applications in biotechnology. © 2017 The Authors Protein Science published by Wiley Periodicals, Inc. on behalf of The Protein Society.

  14. Coiled coil peptides as universal linkers for the attachment of recombinant proteins to polymer therapeutics

    Czech Academy of Sciences Publication Activity Database

    Pechar, Michal; Pola, Robert; Laga, Richard; Ulbrich, Karel; Bednárová, Lucie; Maloň, Petr; Sieglová, Irena; Král, Vlastimil; Fábry, Milan; Vaněk, O.

    2011-01-01

    Roč. 12, č. 10 (2011), s. 3645-3655 ISSN 1525-7797 R&D Projects: GA ČR GA203/08/0543; GA MŠk 1M0505 Institutional research plan: CEZ:AV0Z40500505; CEZ:AV0Z40550506; CEZ:AV0Z50520514 Keywords : coiled coil * polymer therapeutics * drug targeting Subject RIV: CC - Organic Chemistry Impact factor: 5.479, year: 2011

  15. Plasmodium vivax antigen discovery based on alpha-helical coiled coil protein motif.

    Directory of Open Access Journals (Sweden)

    Nora Céspedes

    Full Text Available Protein α-helical coiled coil structures that elicit antibody responses, which block critical functions of medically important microorganisms, represent a means for vaccine development. By using bioinformatics algorithms, a total of 50 antigens with α-helical coiled coil motifs orthologous to Plasmodium falciparum were identified in the P. vivax genome. The peptides identified in silico were chemically synthesized; circular dichroism studies indicated partial or high α-helical content. Antigenicity was evaluated using human sera samples from malaria-endemic areas of Colombia and Papua New Guinea. Eight of these fragments were selected and used to assess immunogenicity in BALB/c mice. ELISA assays indicated strong reactivity of serum samples from individuals residing in malaria-endemic regions and sera of immunized mice, with the α-helical coiled coil structures. In addition, ex vivo production of IFN-γ by murine mononuclear cells confirmed the immunogenicity of these structures and the presence of T-cell epitopes in the peptide sequences. Moreover, sera of mice immunized with four of the eight antigens recognized native proteins on blood-stage P. vivax parasites, and antigenic cross-reactivity with three of the peptides was observed when reacted with both the P. falciparum orthologous fragments and whole parasites. Results here point to the α-helical coiled coil peptides as possible P. vivax malaria vaccine candidates as were observed for P. falciparum. Fragments selected here warrant further study in humans and non-human primate models to assess their protective efficacy as single components or assembled as hybrid linear epitopes.

  16. Data-Driven Prediction and Design of bZIP Coiled-Coil Interactions

    Science.gov (United States)

    Potapov, Vladimir; Kaplan, Jenifer B.; Keating, Amy E.

    2015-01-01

    Selective dimerization of the basic-region leucine-zipper (bZIP) transcription factors presents a vivid example of how a high degree of interaction specificity can be achieved within a family of structurally similar proteins. The coiled-coil motif that mediates homo- or hetero-dimerization of the bZIP proteins has been intensively studied, and a variety of methods have been proposed to predict these interactions from sequence data. In this work, we used a large quantitative set of 4,549 bZIP coiled-coil interactions to develop a predictive model that exploits knowledge of structurally conserved residue-residue interactions in the coiled-coil motif. Our model, which expresses interaction energies as a sum of interpretable residue-pair and triplet terms, achieves a correlation with experimental binding free energies of R = 0.68 and significantly out-performs other scoring functions. To use our model in protein design applications, we devised a strategy in which synthetic peptides are built by assembling 7-residue native-protein heptad modules into new combinations. An integer linear program was used to find the optimal combination of heptads to bind selectively to a target human bZIP coiled coil, but not to target paralogs. Using this approach, we designed peptides to interact with the bZIP domains from human JUN, XBP1, ATF4 and ATF5. Testing more than 132 candidate protein complexes using a fluorescence resonance energy transfer assay confirmed the formation of tight and selective heterodimers between the designed peptides and their targets. This approach can be used to make inhibitors of native proteins, or to develop novel peptides for applications in synthetic biology or nanotechnology. PMID:25695764

  17. Application of Coiled Coil Peptides in Liposomal Anticancer Drug Delivery Using a Zebrafish Xenograft Model.

    Science.gov (United States)

    Yang, Jian; Shimada, Yasuhito; Olsthoorn, René C L; Snaar-Jagalska, B Ewa; Spaink, Herman P; Kros, Alexander

    2016-08-23

    The complementary coiled coil forming peptides E4 [(EIAALEK)4] and K4 [(KIAALKE)4] are known to trigger liposomal membrane fusion when tethered to lipid vesicles in the form of lipopeptides. In this study, we examined whether these coiled coil forming peptides can be used for drug delivery applications. First, we prepared E4 peptide modified liposomes containing the far-red fluorescent dye TO-PRO-3 iodide (E4-Lipo-TP3) and confirmed that E4-liposomes could deliver TP3 into HeLa cells expressing K4 peptide on the membrane (HeLa-K) under cell culture conditions in a selective manner. Next, we prepared doxorubicin-containing E4-liposomes (E4-Lipo-DOX) and confirmed that E4-liposomes could also deliver DOX into HeLa-K cells. Moreover, E4-Lipo-DOX showed enhanced cytotoxicity toward HeLa-K cells compared to free doxorubicin. To prove the suitability of E4/K4 coiled coil formation for in vivo drug delivery, we injected E4-Lipo-TP3 or E4-Lipo-DOX into zebrafish xenografts of HeLa-K. As a result, E4-liposomes delivered TP3 to the implanted HeLa-K cells, and E4-Lipo-DOX could suppress cancer proliferation in the xenograft when compared to nontargeted conditions (i.e., zebrafish xenograft with free DOX injection). These data demonstrate that coiled coil formation enables drug selectivity and efficacy in vivo. It is envisaged that these findings are a step forward toward biorthogonal targeting systems as a tool for clinical drug delivery.

  18. Coiled-coil coactivators play a structural role mediating interactions in hypoxia-inducible factor heterodimerization.

    Science.gov (United States)

    Guo, Yirui; Scheuermann, Thomas H; Partch, Carrie L; Tomchick, Diana R; Gardner, Kevin H

    2015-03-20

    The hypoxia-inducible factor complex (HIF-α·aryl hydrocarbon receptor nuclear translocator (ARNT)) requires association with several transcription coactivators for a successful cellular response to hypoxic stress. In addition to the conventional global transcription coactivator CREB-binding protein/p300 (CBP/p300) that binds to the HIF-α transactivation domain, a new group of transcription coactivators called the coiled-coil coactivators (CCCs) interact directly with the second PER-ARNT-SIM (PAS) domain of ARNT (ARNT PAS-B). These less studied transcription coactivators play essential roles in the HIF-dependent hypoxia response, and CCC misregulation is associated with several forms of cancer. To better understand CCC protein recruitment by the heterodimeric HIF transcription factor, we used x-ray crystallography, NMR spectroscopy, and biochemical methods to investigate the structure of the ARNT PAS-B domain in complex with the C-terminal fragment of a coiled-coil coactivator protein, transforming acidic coiled-coil coactivator 3 (TACC3). We found that the HIF-2α PAS-B domain also directly interacts with TACC3, motivating an NMR data-derived model suggesting a means by which TACC3 could form a ternary complex with HIF-2α PAS-B and ARNT PAS-B via β-sheet/coiled-coil interactions. These findings suggest that TACC3 could be recruited as a bridge to cooperatively mediate between the HIF-2α PAS-B·ARNT PAS-B complex, thereby participating more directly in HIF-dependent gene transcription than previously anticipated. © 2015 by The American Society for Biochemistry and Molecular Biology, Inc.

  19. Transport of one SC coil through the village of Meyrin

    CERN Multimedia

    1956-01-01

    The energizing coils of the Synchro-cyclotron magnet were manufactured in Belgium before travelling to Basel in Switzerland by boat and continuing by road to Geneva. The first coil reached Geneva in December 1955, with the second following in early 1956. The coils were stored in a hangar at the Geneva airport before they were brought to CERN in May 1956.

  20. The umbilical coiling index, a review of the literature

    NARCIS (Netherlands)

    de Laat, Monique W. M.; Franx, Arie; van Alderen, Elise D.; Nikkels, Peter G. J.; Visser, Gerard H. A.

    2005-01-01

    Our aim was to review the literature on umbilical cord coiling. Relevant articles in English published between 1966 and 2003 were retrieved by a Medline search and cross-referencing. The normal umbilical cord coiling index (UCI) is 0.17 (+/- 0.009) spirals completed per cm. Abnormal cord coiling,

  1. The Roach muscle bundle and umbilical cord coiling

    NARCIS (Netherlands)

    de Laat, Monique W. M.; Nikkels, Peter G. J.; Franx, Arie; Visser, Gerard H. A.

    2007-01-01

    To determine if presence of the Roach muscle, a small muscle bundle lying just beside the umbilical artery, contributes to umbilical cord coiling. 251 umbilical cords were examined. The umbilical coiling index (UCI) was calculated as the number of coils divided by the cord length in cm. Cords were

  2. The coil array method for creating a dynamic imaging volume.

    Science.gov (United States)

    Smith, Elliot; Freschi, Fabio; Repetto, Maurizio; Crozier, Stuart

    2017-08-01

    Gradient strength and speed are limited by peripheral nerve stimulation (PNS) thresholds. The coil array method allows the gradient field to be moved across the imaging area. This can help reduce PNS and provide faster imaging for image-guided therapy systems such as the magnetic resonance imaging-guided linear accelerator (MRI-linac). The coil array is designed such that many coils produce magnetic fields, which combine to give the desired gradient profile. The design of the coil array uses two methods: either the singular value decomposition (SVD) of a set of field profiles or the electromagnetic modes of the coil surface. Two whole-body coils and one experimental coil were designed to investigate the method. The field produced by the experimental coil was compared to simulated results. The experimental coil region of uniformity (ROU) was moved along the z axis as shown in simulation. The highest observed field deviation was 16.9% at the edge of the ROU with a shift of 35 mm. The whole-body coils showed a median field deviation across all offsets below 5% with an eight-coil basis when using the SVD design method. Experimental results show the feasibility of a moving imaging region within an MRI with a low number of coils in the array. Magn Reson Med 78:784-793, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  3. Strain and stress of the ASDEX multipole magnetic coils

    International Nuclear Information System (INIS)

    Jandl, O.; Pillsticker, M.

    1978-01-01

    A brief description of the technical concept of the multipole magnetic field coils for the ASDEX tokamak is given. The various loads of the coils are explained in quality. To compute displacement and stress of the coils FEM computer programs are used. The computing models applied to this problem are founded and the results and the conclusions are reported. (orig.) [de

  4. Preferred side-chain constellations at antiparallel coiled-coil interfaces.

    Science.gov (United States)

    Hadley, Erik B; Testa, Oliver D; Woolfson, Derek N; Gellman, Samuel H

    2008-01-15

    Reliable predictive rules that relate protein sequence to structure would facilitate postgenome predictive biology and the engineering and de novo design of peptides and proteins. Through a combination of experiment and analysis of the protein data bank (PDB), we have deciphered and rationalized new rules for helix-helix interfaces of a common protein-folding and association motif, the antiparallel dimeric coiled coil. These interfaces are defined by a specific pattern of interactions among largely hydrophobic side chains often referred to as knobs-into-holes (KIH) packing: a knob from one helix inserts into a hole formed by four residues on the partner. Previous work has focused on lateral interactions within the KIH motif, for example, between an a position on one helix and a d' position on the other in an antiparallel coiled coil. We show that vertical interactions within the KIH motif, such as a'-a-a', are energetically important as well. The experimental and database analyses concur regarding preferred vertical combinations, which can be rationalized as leading to favorable side-chain interactions that we call constellations. The findings presented here highlight an unanticipated level of complexity in coiled-coil interactions, and our analysis of a few specific constellations illustrates a general, multipronged approach to addressing this complexity.

  5. Historical review: another 50th anniversary--new periodicities in coiled coils.

    Science.gov (United States)

    Gruber, Markus; Lupas, Andrei N

    2003-12-01

    In 1953, Francis Crick and Linus Pauling both proposed models of supercoiled alpha helices ('coiled coils') for the structure of keratin. These were the first attempts at modelling the tertiary structure of a protein. Crick emphasized the packing mode of the side-chains ('knobs-into-holes'), which required a periodicity of seven residues over two helical turns (7/2) and a supercoil in the opposite sense of the constituent helices. By contrast, Pauling envisaged a broader set of periodicities (4/1, 7/2, 18/5, 15/4, 11/3) and supercoils of both senses. Crick's model became canonical and the 'heptad repeat' essentially synonymous with coiled coils, but 50 years later new crystal structures and protein sequences show that the less common periodicities envisaged by Pauling also occur in coiled coils, adding a variant packing mode ('knobs-to-knobs') to the standard model. Pauling's laboratory notebooks suggest that he searched unsuccessfully for this packing mode in 1953.

  6. Role of the coiled-coil tip of Escherichia coli DksA in promoter control

    Science.gov (United States)

    Lee, Jeong-Hyun; Lennon, Christopher W.; Ross, Wilma; Gourse, Richard L.

    2012-01-01

    E. coli DksA works in conjunction with the small molecule ppGpp to regulate transcription initiation negatively or positively, depending on the identity of the promoter. DksA is in a class of transcription factors that do not bind directly to DNA like classical repressors or activators but rather bind in the RNA polymerase (RNAP) secondary channel like the transcription elongation factors GreA and GreB in E. coli and TFIIS in eukaryotes. We found that substitution for either of two residues in its coiled-coil tip, D74 or A76, eliminates DksA function without affecting its apparent affinity for RNAP. The properties of DksA-Gre factor chimeras indicated that the coiled-coil tip is responsible for the DksA-specific effects on open complex formation. A conservative substitution at position 74, D74E, resulted in a loss of DksA function in both negative and positive control, and an E44D substitution at the analogous position in GreA resulted in a gain of function in both negative and positive control. That a single methylene group has such an extraordinary effect on these transcription factors highlights the critical nature of the identity of coiled-coil tip interactions with RNAP for open complex formation. PMID:22200485

  7. Coiled-Coil Proteins Facilitated the Functional Expansion of the Centrosome

    Science.gov (United States)

    Kuhn, Michael; Hyman, Anthony A.; Beyer, Andreas

    2014-01-01

    Repurposing existing proteins for new cellular functions is recognized as a main mechanism of evolutionary innovation, but its role in organelle evolution is unclear. Here, we explore the mechanisms that led to the evolution of the centrosome, an ancestral eukaryotic organelle that expanded its functional repertoire through the course of evolution. We developed a refined sequence alignment technique that is more sensitive to coiled coil proteins, which are abundant in the centrosome. For proteins with high coiled-coil content, our algorithm identified 17% more reciprocal best hits than BLAST. Analyzing 108 eukaryotic genomes, we traced the evolutionary history of centrosome proteins. In order to assess how these proteins formed the centrosome and adopted new functions, we computationally emulated evolution by iteratively removing the most recently evolved proteins from the centrosomal protein interaction network. Coiled-coil proteins that first appeared in the animal–fungi ancestor act as scaffolds and recruit ancestral eukaryotic proteins such as kinases and phosphatases to the centrosome. This process created a signaling hub that is crucial for multicellular development. Our results demonstrate how ancient proteins can be co-opted to different cellular localizations, thereby becoming involved in novel functions. PMID:24901223

  8. A review of direct experimental measurements of detachment

    Science.gov (United States)

    Boedo, J.; McLean, A. G.; Rudakov, D. L.; Watkins, J. G.

    2018-04-01

    Detached divertor plasmas feature strong radial and parallel gradients of density, temperature, electric fields and flow over the divertor volume and therefore, sampling the divertor plasma directly provides crucial knowledge to the interpretation and modeling efforts. We review the contribution of diagnostics that directly sample the plasma to the advancement of knowledge of the physics of detachment and detached divertors, such as the characteristics of the various regimes, discovery and quantification of drifts and identification of convection of heat and particles. We focus on wall probes, scanning probes, retarding field analyzers and Thomson scattering in the divertor region and also include the contribution of measurements away from the divertor that provide insight on how divertor detachment affects core, edge or pedestal conditions. Wall probes are critical as they can be installed in closed volumes of difficult access to other diagnostics and measure plasma parameters at the divertor structures, which define the plasma boundary conditions and where detachment effects are more likely to be strongest.

  9. Adhesion and detachment of a capsule in axisymmetric flow

    Science.gov (United States)

    Keh, M. P.; Leal, L. G.

    2016-05-01

    The adhesion and detachment of a capsule on a solid boundary surface is studied via a combination of scaling theory and numerical simulation and the behavior is compared and contrasted with a vesicle. It is shown that the dominant physical property for both capsules and vesicles is the area dilation modulus Ks of the membrane. The nonzero shear modulus Gs for capsules increases the resistance to deformation and thus decreases slightly the equilibrium contact radius for an adhered capsule compared to an adhered vesicle. The detachment process in this study is due to an external axisymmetric flow. Unlike a rigid body that must be pulled away without change of shape, capsules (and vesicles) almost always detach dominantly by peeling in which the contact radius decreases but the minimum separation distance does not change until the final moments of detachment. Compared to a vesicle with the same Ks, a capsule maintains a more compact shape and is harder to elongate under a given external flow. Hence, the detachment process is slower for capsules compared to vesicles with the same Ks.

  10. Miocene detachment faulting predating EPR propagation: Southern Baja California

    Science.gov (United States)

    Bot, Anna; Geoffroy, Laurent; Authemayou, Christine; Bellon, Hervé; Graindorge, David; Pik, Raphaël.

    2016-05-01

    At the southern tip of the Baja California peninsula, we characterize the onshore structures and kinematics associated with crustal necking leading up to the Pliocene breakup and early East Pacific Rise seafloor spreading. From a combination of tectonic field investigations, K-Ar and cosmogenic isotope dating and geomorphology, we propose that the Los Cabos block represents the exhumed footwall of a major detachment fault. This north trending detachment fault is marked by a conspicuous low-dipping brittle-ductile shear zone showing a finite displacement with top to the SE ending to the ESE. This major feature is associated with fluid circulations which led to rejuvenation of the deformed Cretaceous magmatic rocks at a maximum of 17.5 Ma. The detachment footwall displays kilometer-scale corrugations controlling the present-day drainage pattern. This major detachment is synchronous with the development of the San José del Cabo Basin where syntectonic sedimentation took place from the middle Miocene to probably the early Pliocene. We propose that this seaward dipping detachment fault accommodates the proximal crustal necking of the Baja California passive margin, which predates the onset of formation of the East Pacific Rise spreading axis in the Cabo-Puerto Vallarta segment. Our data illustrate an apparent anticlockwise rotation of the stretching direction in Baja California Sur from ~17 Ma to the Pliocene.

  11. Surgical and Visual Outcome for Recurrent Retinal Detachment Surgery

    Directory of Open Access Journals (Sweden)

    Constantin Pournaras

    2014-01-01

    Full Text Available Purpose. To evaluate the anatomical and functional outcome of repeated surgeries for recurrent retinal detachment. Methods. We retrospectively reviewed 70 cases with refractory retinal detachment of various etiologies that required multiple operations. Anatomical success (attached retina or failure (totally/partially-detached retina was assessed biomicroscopically. The BCVA was used for the evaluation of the functional outcome, at presentation and at the end of follow-up. Various pre-, intra-, and postoperative factors were associated with anatomical success or failure as well as with final functionality. Results. The mean number of surgeries was 4 (range: 2 to 10. The anatomical success rate was 80% (56 attached cases, 14 detached cases. 29% of the attached cases had a BCVA better than 20/40 (Snellen chart. The number of operations doesn’t seem to affect significantly the final visual acuity. The PVR was found to affect both the anatomical and functional outcome (P=0.014 & P=0.002, respectively. Conclusions. In the present study, it is suggested that multiple operations for refractory retinal detachment may result in successful anatomic results, with a fare functional outcome at the same time. Eventually, we verified that the existence of PVR worsens the prognosis.

  12. Lattice degeneration of the retina and retinal detachment.

    Science.gov (United States)

    Semes, L P

    1992-01-01

    Lattice retinal degeneration is considered the most significant peripheral retinal disorder potentially predisposing to retinal breaks and retinal detachment. Lattice degeneration affects the vitreous and inner retinal layers with secondary changes as deep as the retinal pigment epithelium and perhaps the choriocapillaris. Variations in clinical appearance are the rule; geographically, lattice lesions favor the vertical meridians between the equator and the ora serrata. Lattice degeneration begins early in life and has been reported in sequential generations of the same family. Along with its customary bilateral occurrence, lattice shares other characteristics of a dystrophy. The association between the vitreous and retina in lattice lesions may be responsible for the majority of lattice-induced retinal detachments. The tumultuous event of posterior vitreous separation in the presence of abnormally strong vitreoretinal adherence is the trigger for a retinal tear that, in turn, may lead to retinal detachment. Although retinal holes in young patients with lattice degeneration may play a role in the evolution of retinal detachment, the clinical course of lattice degeneration seems to be one of dormancy rather than of progressive change. This discussion outlines the pathophysiology of lattice retinal degeneration and the relationship of pathophysiology to clinical presentation. The epidemiology of lattice degeneration is summarized, as are the possible precursors to retinal detachment. A clinical characterization of the natural history of lattice degeneration is offered, and interventions for complications are described. To conclude, management strategies from a primary-care standpoint are reviewed.

  13. [Preventive treatment of retinal detachment in aphakic eyes].

    Science.gov (United States)

    Regnault, F; Bregeat, P

    1977-01-01

    We have examined 243 cases with retinal detachment occurring within 6 months following cataract surgery. In 92 of them retinal tear was due to lattice degeneration, in 66 to snail track degeneration and in 17 to equatorial degeneration. 290 other patients had preventive treatments. In this group, there were only 10 cases of retinal detachment. 9 out of 22 patients who had no preventive treatment suffered retinal detachments. There are two reasons for the occurrence of this retinal detachment in the 6 months following cataract surgery in eyes where retinal degenerations are found: (1) surgical trauma even with cryoextraction is responsible for traction of the vitreous base, (2) rapid disappearance of the hyaluronic acid in the aphakic vitreous is responsible for the degradation of the vitreous with formation of large zones of liquid vitreous. When adhesion between the vitreous and the retinal degeneration area remains, the traction is responsible for retinal tear or retinal detachment. The importance of the preventive treatment of retinal lesions prior to cataract surgery should be stressed.

  14. The fellow eye of patients with phakic lattice retinal detachment.

    Science.gov (United States)

    Folk, J C; Arrindell, E L; Klugman, M R

    1989-01-01

    A retrospective study was performed to determine whether the prophylactic treatment of areas of lattice degeneration, holes, or breaks reduced the risk of subsequent new breaks or detachment in the fellow undetached phakic eyes of patients with a phakic lattice retinal detachment (RD). Three hundred eighty-eight consecutive patients who presented to the University of Iowa between 1959 and 1984 were followed for a mean of 7.9 +/- 5.8 years after the detachment in the first eye. Fellow eyes which received no prophylactic treatment had a 2.5 times greater risk of a new break or RD over 7 years than eyes receiving full prophylactic treatment (19.4 versus 7.5%; P = 0.0002). Fellow eyes receiving no treatment also had a greater risk of a new RD over 7 years than eyes receiving full treatment (5.1 versus 1.8%; P = 0.0125). These results do not allow us to make recommendations concerning which fellow eyes, if any, should be prophylactically treated. On the one hand, prophylactic treatment did significantly reduce the risk of new breaks and detachments. On the other hand, however, prophylactic treatment reduced the risk of new RD alone in the fellow eye only from 5.1 to 1.8% over 7 years. In addition, prophylactic treatment did not reduce the risk of detachment in the higher risk eyes with high myopia or extensive lattice.

  15. Modeling the shape of a noncircular toroidal field coil

    International Nuclear Information System (INIS)

    Shah, V.N.; Marshall, N.H.

    1983-01-01

    Operating and transient forces acting on toroidal field coils may cause conductors and insulation to slide or break and may lead to quenching of the coil. Therefore, it is essential that each individual turn of the coil be modeled for detailed analysis of the coil structure. For this, a special purpose computer program is needed. As a first step in developing such a computer program, the authors present a finite element analysis of a turn of noncircular coil subjected to electromagnetic loading. A turn of superconducting coil is represented by a thin ring modeled by curved finite elements. Of the several curved beam elements reported in the literature, the strain element with two nodes, six degrees-of-freedom, and constant radius of curvature converges fastest for thin-deep arches whose geometrical characteristics are similar to those of a turn of toroidal field coil. They present an algorithm to model a noncircular ring using the number of strain elements satisfying the continuity of slopes at their nodes. This paper verifies the finite element model of a coil shape subjected to a toroidal magnetic field by solving three problems: circular and elliptic coils with the same inner and outer radii, a D-shaped coil, and a compound coil consisting of C- and D-shaped segments. The first problem shows that the resultant vertical force in the upper half of the coil is independent of coil shape. The remaining two problems calculate stresses that represent the constant tension in the D-shaped coil and in each segment of the compound coil. The results of the three problems compare well with the analytical results

  16. Computational study for the effects of coil configuration on blood flow characteristics in coil-embolized cerebral aneurysm.

    Science.gov (United States)

    Otani, Tomohiro; Ii, Satoshi; Shigematsu, Tomoyoshi; Fujinaka, Toshiyuki; Hirata, Masayuki; Ozaki, Tomohiko; Wada, Shigeo

    2017-05-01

    Coil embolization of cerebral aneurysms with inhomogeneous coil distribution leads to an incomplete occlusion of the aneurysm. However, the effects of this factor on the blood flow characteristics are still not fully understood. This study investigates the effects of coil configuration on the blood flow characteristics in a coil-embolized aneurysm using computational fluid dynamics (CFD) simulation. The blood flow analysis in the aneurysm with coil embolization was performed using a coil deployment (CD) model, in which the coil configuration was constructed using a physics-based simulation of the CD. In the CFD results, total flow momentum and kinetic energy in the aneurysm gradually decayed with increasing coil packing density (PD), regardless of the coil configuration attributed to deployment conditions. However, the total shear rate in the aneurysm was relatively high and the strength of the local shear flow varied based on the differences in coil configuration, even at adequate PDs used in clinical practice (20-25 %). Because the sufficient shear rate reduction is a well-known factor in the blood clot formation occluding the aneurysm inside, the present study gives useful insight into the effects of coil configuration on the treatment efficiency of coil embolization.

  17. Subunit b-Dimer of the Escherichia coli ATP Synthase Can Form Left-Handed Coiled-Coils

    Science.gov (United States)

    Wise, John G.; Vogel, Pia D.

    2008-01-01

    One remaining challenge to our understanding of the ATP synthase concerns the dimeric coiled-coil stator subunit b of bacterial synthases. The subunit b-dimer has been implicated in important protein interactions that appear necessary for energy conservation and that may be instrumental in energy conservation during rotary catalysis by the synthase. Understanding the stator structure and its interactions with the rest of the enzyme is crucial to the understanding of the overall catalytic mechanism. Controversy exists on whether subunit b adopts a classic left-handed or a presumed right-handed dimeric coiled-coil and whether or not staggered pairing between nonhomologous residues in the homodimer is required for intersubunit packing. In this study we generated molecular models of the Escherichia coli subunit b-dimer that were based on the well-established heptad-repeat packing exhibited by left-handed, dimeric coiled-coils by employing simulated annealing protocols with structural restraints collected from known structures. In addition, we attempted to create hypothetical right-handed coiled-coil models and left- and right-handed models with staggered packing in the coiled-coil domains. Our analyses suggest that the available structural and biochemical evidence for subunit b can be accommodated by classic left-handed, dimeric coiled-coil quaternary structures. PMID:18326648

  18. Structural attributes for the recognition of weak and anomalous regions in coiled-coils of myosins and other motor proteins

    Science.gov (United States)

    2012-01-01

    Background Coiled-coils are found in different proteins like transcription factors, myosin tail domain, tropomyosin, leucine zippers and kinesins. Analysis of various structures containing coiled-coils has revealed the importance of electrostatic and hydrophobic interactions. In such domains, regions of different strength of interactions need to be identified since they could be biologically relevant. Findings We have updated our coiled-coil validation webserver, now called COILCHECK+, where new features were added to efficiently identify the strength of interaction at the interface region and measure the density of charged residues and hydrophobic residues. We have examined charged residues and hydrophobic ladders, using a new algorithm called CHAHO, which is incorporated within COILCHECK + server. CHAHO permits the identification of spatial charged residue patches and the continuity of hydrophobic ladder which stabilizes and destabilizes the coiled-coil structure. Conclusions The availability of such computational tools should be useful to understand the importance of spatial clustering of charged residues and the continuity of hydrophobic residues at the interface region of coiled-coil dimers. COILCHECK + is a structure based tool to validate coiled-coil stability; it can be accessed at http://caps.ncbs.res.in/coilcheckplus. PMID:23009691

  19. CCBuilder: an interactive web-based tool for building, designing and assessing coiled-coil protein assemblies.

    Science.gov (United States)

    Wood, Christopher W; Bruning, Marc; Ibarra, Amaurys Á; Bartlett, Gail J; Thomson, Andrew R; Sessions, Richard B; Brady, R Leo; Woolfson, Derek N

    2014-11-01

    The ability to accurately model protein structures at the atomistic level underpins efforts to understand protein folding, to engineer natural proteins predictably and to design proteins de novo. Homology-based methods are well established and produce impressive results. However, these are limited to structures presented by and resolved for natural proteins. Addressing this problem more widely and deriving truly ab initio models requires mathematical descriptions for protein folds; the means to decorate these with natural, engineered or de novo sequences; and methods to score the resulting models. We present CCBuilder, a web-based application that tackles the problem for a defined but large class of protein structure, the α-helical coiled coils. CCBuilder generates coiled-coil backbones, builds side chains onto these frameworks and provides a range of metrics to measure the quality of the models. Its straightforward graphical user interface provides broad functionality that allows users to build and assess models, in which helix geometry, coiled-coil architecture and topology and protein sequence can be varied rapidly. We demonstrate the utility of CCBuilder by assembling models for 653 coiled-coil structures from the PDB, which cover >96% of the known coiled-coil types, and by generating models for rarer and de novo coiled-coil structures. CCBuilder is freely available, without registration, at http://coiledcoils.chm.bris.ac.uk/app/cc_builder/. © The Author 2014. Published by Oxford University Press.

  20. Metabolism during ECM Detachment: Achilles Heel of Cancer Cells?

    Science.gov (United States)

    Mason, Joshua A; Hagel, Kimberly R; Hawk, Mark A; Schafer, Zachary T

    2017-07-01

    Integrin-mediated attachment to the extracellular matrix (ECM) is required to combat the induction of programmed cell death in a variety of distinct cell types. If cells fail to maintain proper ECM attachment, they become subject to elimination via an apoptotic cell death program known as anoikis. However, anoikis inhibition is not sufficient to promote the long-term survival of ECM-detached cells. Several recent studies have unveiled the profound (anoikis-independent) impact of cell metabolism on the viability of ECM-detached cells. Thus, we posit that, during metastatic dissemination (when cancer cells are exposed to periods of ECM detachment), cancer cells must alter their metabolism in a fashion that promotes survival and ultimately contributes to metastatic outgrowth. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Simulation of experimentally achieved detached plasmas using the UEDGE code

    International Nuclear Information System (INIS)

    Porter, G.D.; Allen, S.; Fenstermacher, M.

    1995-01-01

    The introduction of a divertor Thomson scattering system in DIII-D has enabled accurate determination of the plasma properties in the divertor region. We identify two plasma regimes; detached and attached. The electron temperature in the detached regime is about 2 eV, much lower than 5 to 10 eV determined earlier. We show that fluid models of the DIII-D scrape-off layer plasma are able to reproduce many of the features of these two plasma regimes, including the boundaries for transition between them. Detailed comparison between the results obtained from the fluid models and experiment suggest the models underestimate the spatial extent of the low temperature region associated the detached plasma mode. We suggest that atomic physics processes at the low electron temperatures reported here may account for this discrepancy

  2. [Retinal pneumopexy in the treatment of rhegmatogenous retinal detachment].

    Science.gov (United States)

    Levai, L; Gavriş, Monica; Gábor, Radó; Bagosi, P

    2014-01-01

    To evaluate the efficiency of retinal pneumopexy in patients with rhegmatogenous retinal detachment. This clinical prospective study unrolled between november 2010-june 2012 in the Ophthalmology Department of the Military Hospital in Cluj-Napoca and Satu Mare Emergency Hospital included 20 patients (20 eyes) with rhegmatogenous retinal detachment. Patients were treated with retinal pneumopexy followed by laser photocoagulation. Anatomical and functional results were evaluated 1, 3, 6, 12 and 19 months after treatment. In 17 eyes out of 20, we achieved retinal reattachment and visual recovery. Three cases yelded no success, these being further treated with posterior vitrectomy. Retinal pneumopexy is a minimally invasive treatment method of rhegmatogenous retinal detachment with very good results in well selected cases.

  3. An Unusual Case of Extensive Lattice Degeneration and Retinal Detachment.

    Science.gov (United States)

    Mathew, David J; Sarma, Saurabh Kumar; Basaiawmoit, Jennifer V

    2016-07-01

    Lattice degeneration of the retina is not infrequently encountered on a dilated retinal examination and many of them do not need any intervention. We report a case of atypical lattice degeneration variant with peripheral retinal detachment. An asymptomatic 35-year-old lady with minimal refractive error was found to have extensive lattice degeneration, peripheral retinal detachment and fibrotic changes peripherally with elevation of retinal vessels on dilated retinal examination. There were also areas of white without pressure, chorioretinal scarring and retinal breaks. All the changes were limited to beyond the equator but were found to span 360 degrees. She was treated with barrage laser all around to prevent extension of the retinal detachment posteriorly. She remained stable till her latest follow-up two years after the barrage laser. This case is reported for its rarity with a discussion of the probable differential diagnoses. To the best of our knowledge, this is the first report of such findings in lattice degeneration.

  4. Peripheral retinal degenerations and the risk of retinal detachment.

    Science.gov (United States)

    Lewis, Hilel

    2003-07-01

    To review the degenerative diseases of the peripheral retina in relationship with the risk to develop a rhegmatogenous retinal detachment and to present recommendations for use in eyes at increased risk of developing a retinal detachment. Focused literature review and author's clinical experience. Retinal degenerations are common lesions involving the peripheral retina, and most of them are clinically insignificant. Lattice degeneration, degenerative retinoschisis, cystic retinal tufts, and, rarely, zonular traction tufts, can result in a rhegmatogenous retinal detachment. Therefore, these lesions have been considered for prophylactic therapy; however, adequate studies have not been performed to date. Well-designed, prospective, randomized clinical studies are necessary to determine the benefit-risk ratio of prophylactic treatment. In the meantime, the evidence available suggests that most of the peripheral retinal degenerations should not be treated except in rare, high-risk situations.

  5. Umbilical Cord Coiling and Zygosity: Is there a Link?

    Science.gov (United States)

    Coetzee, André Joannou; Castro, Eumenia; Peres, Luiz Cesar

    2015-01-01

    The aim of this study was to analyze abnormalities of umbilical coiling index (UCI) in twin gestation to test whether the coiling is genetically influenced by zygosity. Data retrieved comprised gestational age (GA), chorionicity, fetal gender, and UCI. The mean UCI of hypercoiled cords in monochorionic placentas was 0.55 coils/cm and 0.49 coils/cm in dichorionic placentas with discordant fetal gender (P = 0.2629). In conclusion, no significant statistical difference between UCI in monochorionic and dichorionic twin placentas with discordant fetal gender was identified, suggesting that zygosity does not play a role in umbilical coiling induction.

  6. SSC [Superconducting Super Collider] dipole coil production tooling

    International Nuclear Information System (INIS)

    Carson, J.A.; Barczak, E.J.; Bossert, R.C.; Brandt, J.S.; Smith, G.A.

    1989-03-01

    Superconducting Super Collider dipole coils must be produced to high precision to ensure uniform prestress and even conductor distribution within the collared coil assembly. Tooling is being prepared at Fermilab for the production of high precision 1M and 16.6M SSC dipole coils suitable for mass production. The design and construction methods builds on the Tevatron tooling and production experience. Details of the design and construction methods and measured coil uniformity of 1M coils will be presented. 4 refs., 10 figs

  7. SSC (Superconducting Super Collider) dipole coil production tooling

    Energy Technology Data Exchange (ETDEWEB)

    Carson, J.A.; Barczak, E.J.; Bossert, R.C.; Brandt, J.S.; Smith, G.A.

    1989-03-01

    Superconducting Super Collider dipole coils must be produced to high precision to ensure uniform prestress and even conductor distribution within the collared coil assembly. Tooling is being prepared at Fermilab for the production of high precision 1M and 16.6M SSC dipole coils suitable for mass production. The design and construction methods builds on the Tevatron tooling and production experience. Details of the design and construction methods and measured coil uniformity of 1M coils will be presented. 4 refs., 10 figs.

  8. The IEA large coil task test results in IFSMTF

    International Nuclear Information System (INIS)

    Lubell, M.S.; Clinard, J.A.; Dresner, L.

    1987-01-01

    The Large Coil Task (LCT) is an international collaboration of the United States, EURATOM, Japan, and Switzerland to develop large superconducting magnets for fusion reactors. The testing phase of LCT was completed on September 3, 1987. All six coils exceeded the design goals, both as single coils and in six-coil toroidal tests. In addition, a symmetric torus test was performed in which a maximum field of 9 T was reached in all coils simultaneously. These are by far the largest magnets (either in size, weight, or stored energy) ever to achieve such a field. 6 refs., 6 figs., 3 tabs

  9. Random coil chemical shift for intrinsically disordered proteins

    DEFF Research Database (Denmark)

    Kjærgaard, Magnus; Brander, Søren; Poulsen, Flemming Martin

    2011-01-01

    Secondary chemical shift analysis is the main NMR method for detection of transiently formed secondary structure in intrinsically disordered proteins. The quality of the secondary chemical shifts is dependent on an appropriate choice of random coil chemical shifts. We report random coil chemical....... Temperature has a non-negligible effect on the (13)C random coil chemical shifts, so temperature coefficients are reported for the random coil chemical shifts to allow extrapolation to other temperatures. The pH dependence of the histidine random coil chemical shifts is investigated in a titration series...

  10. Planar quadrature coil design using shielded-loop resonators

    DEFF Research Database (Denmark)

    Stensgaard, A

    1997-01-01

    The shielded-loop resonator is known to have a low capacitive sample loss due to a perfect balancing. In this paper, it is demonstrated that shielded-loop technology also can be used to improve design of planar quadrature coils. Both a dual-loop circuit and especially a dual-mode circuit may...... benefit from use of shielded-loop resonators. Observations in measurements agree with theory for both a dual-loop coil and a dual-mode coil. The coils were designed for use as transmit/receive coil for 1H imaging and spectroscopy at 4.7 T in rat brain....

  11. Baculovirus FP25K Localization: Role of the Coiled-Coil Domain.

    Science.gov (United States)

    Garretson, Tyler A; McCoy, Jason C; Cheng, Xiao-Wen

    2016-11-01

    Two types of viruses are produced during the baculovirus life cycle: budded virus (BV) and occlusion-derived virus (ODV). A particular baculovirus protein, FP25K, is involved in the switch from BV to ODV production. Previously, FP25K from the model alphabaculovirus Autographa californica multiple nucleopolyhedrovirus (AcMNPV) was shown to traffic ODV envelope proteins. However, FP25K localization and the domains involved are inconclusive. Here we used a quantitative approach to study FP25K subcellular localization during infection using an AcMNPV bacmid virus that produces a functional AcMNPV FP25K-green fluorescent protein (GFP) fusion protein. During cell infection, FP25K-GFP localized primarily to the cytoplasm, particularly amorphous structures, with a small fraction being localized in the nucleus. To investigate the sequences involved in FP25K localization, an alignment of baculovirus FP25K sequences revealed that the N-terminal putative coiled-coil domain is present in all alphabaculoviruses but absent in betabaculoviruses. Structural prediction indicated a strong relatedness of AcMNPV FP25K to long interspersed element 1 (LINE-1) open reading frame 1 protein (ORF1p), which contains an N-terminal coiled-coil domain responsible for cytoplasmic retention. Point mutations and deletions of this domain lead to a change in AcMNPV FP25K localization from cytoplasmic to nuclear. The coiled-coil and C-terminal deletion viruses increased BV production. Furthermore, a betabaculovirus FP25K protein lacking this N-terminal coiled-coil domain localized predominantly to the nucleus and exhibited increased BV production. These data suggest that the acquisition of this N-terminal coiled-coil domain in FP25K is important for the evolution of alphabaculoviruses. Moreover, with the divergence of preocclusion nuclear membrane breakdown in betabaculoviruses and membrane integrity in alphabaculoviruses, this domain represents an alphabaculovirus adaptation for nuclear trafficking

  12. Detached Solidification of Germanium-Silicon Crystals on the ISS

    Science.gov (United States)

    Volz, M. P.; Mazuruk, K.; Croell, A.

    2016-01-01

    A series of Ge(sub 1-x) Si(sub x) crystal growth experiments are planned to be conducted in the Low Gradient Furnace (LGF) onboard the International Space Station. The primary objective of the research is to determine the influence of containment on the processing-induced defects and impurity incorporation in germanium-silicon alloy crystals. A comparison will be made between crystals grown by the normal and "detached" Bridgman methods and the ground-based float zone technique. Crystals grown without being in contact with a container have superior quality to otherwise similar crystals grown in direct contact with a container, especially with respect to impurity incorporation, formation of dislocations, and residual stress in crystals. "Detached" or "dewetted" Bridgman growth is similar to regular Bridgman growth in that most of the melt is in contact with the crucible wall, but the crystal is separated from the wall by a small gap, typically of the order of 10-100 microns. Long duration reduced gravity is essential to test the proposed theory of detached growth. Detached growth requires the establishment of a meniscus between the crystal and the ampoule wall. The existence of this meniscus depends on the ratio of the strength of gravity to capillary forces. On Earth, this ratio is large and stable detached growth can only be obtained over limited conditions. Crystals grown detached on the ground exhibited superior structural quality as evidenced by measurements of etch pit density, synchrotron white beam X-ray topography and double axis X-ray diffraction.

  13. Magnetic Detachment and Plume Control in Escaping Magnetized Plasma

    International Nuclear Information System (INIS)

    Schmit, P.F.; Fisch, N.J.

    2008-01-01

    The model of two-fluid, axisymmetric, ambipolar magnetized plasma detachment from thruster guide fields is extended to include plasmas with non-zero injection angular velocity profiles. Certain plasma injection angular velocity profiles are shown to narrow the plasma plume, thereby increasing exhaust efficiency. As an example, we consider a magnetic guide field arising from a simple current ring and demonstrate plasma injection schemes that more than double the fraction of useful exhaust aperture area, more than halve the exhaust plume angle, and enhance magnetized plasma detachment

  14. Influence of detachment mechanisms on competition in biofilms

    DEFF Research Database (Denmark)

    Morgenroth, Eberhard Friedrich; Wilderer, P. A.

    2000-01-01

    Organism distribution in and morphology of bio®lms are determined by supply of substrate and oxygen and by detachment mechanisms. Based on mathematical simulations, competition of autotrophic and heterotrophic biomass in a bio®lm is discussed for three cases: (1) constant bio®lm thickness, (2...... autotrophic biomass in situations with long intervals between detachment with resulting high variations of the bio®lm thickness. It is concluded that the application of results from mathematical models assuming a constant bio®lm thickness may be misleading when predicting the performance of systems with large...

  15. Bilateral Simultaneous Rhegmatogenous Retinal Detachment following Laser in situ Keratomileusis

    Directory of Open Access Journals (Sweden)

    Erhan Yumusak

    2016-06-01

    Full Text Available A 21-year-old woman developed simultaneous rhegmatogenous retinal detachment after laser in situ keratomileusis (LASIK in both eyes. She underwent pars plana vitrectomy surgery combined with endolaser photocoagulation and silicone oil tamponade in the right eye. A week later, pneumatic retinopexy was done in the left eye. As the retinal tear did not seal, 360° scleral buckling surgery was performed and retina was attached. Bilateral simultaneous rhegmatogenous retinal detachment after LASIK for correction of myopia can be a serious complication. Patients should be informed about the possibility of this complication.

  16. Retinal detachment secondary to ocular perforation during retrobulbar Anaesthesia

    Directory of Open Access Journals (Sweden)

    Gopal Lingam

    1995-01-01

    Full Text Available The clinical characteristics and the retinal breaks associated with rhegmatogenous retinal detachments secondary to accidental globe perforation during local infiltration anaesthesia in five highly myopic eyes are presented. Retinal detachment was total with variable proliferative vitreoretinopathy. The pattern of retinal breaks was rather typical and predictable. Management involved vitreous surgery with internal tamponade by silicone oil in four eyes and perfluoropropane gas in one eye. At the last follow-up, all eyes had attached retina. One eye did not recover useful vision due to possible concurrent optic nerve damage.

  17. Coil supporting device for a nuclear fusion device

    International Nuclear Information System (INIS)

    Kuno, Kazuo.

    1976-01-01

    Object: To reduce a thermal stress of a coil such as a magnetic limiter to minimize stress acting on a protective tube of the coil. Structure: A coil within a protective tube has its outer periphery surrounded and supported by a heat-resisting material such as ceramic at more than two positions suitably spaced lengthwise of a coil conductor, and heat insulating members are interposed between both sides of the coil and the protective tube so that it may be retained with respect to the width of the coil. Further, a heat-resisting resilient member is inserted in a clearance between an outer circumference and an inner circumference of the coil to allow a radial displacement of the coil. As a result, elongation of the coil due to thermal expansion may be escaped at the aforesaid two supports to reduce thermal stress of the coil and protective tube to support the coil within the protective tube in positively heat-resisting and insulating manner. (Kamimura, M.)

  18. Deep brain transcranial magnetic stimulation using variable "Halo coil" system

    Science.gov (United States)

    Meng, Y.; Hadimani, R. L.; Crowther, L. J.; Xu, Z.; Qu, J.; Jiles, D. C.

    2015-05-01

    Transcranial Magnetic Stimulation has the potential to treat various neurological disorders non-invasively and safely. The "Halo coil" configuration can stimulate deeper regions of the brain with lower surface to deep-brain field ratio compared to other coil configurations. The existing "Halo coil" configuration is fixed and is limited in varying the site of stimulation in the brain. We have developed a new system based on the current "Halo coil" design along with a graphical user interface system that enables the larger coil to rotate along the transverse plane. The new system can also enable vertical movement of larger coil. Thus, this adjustable "Halo coil" configuration can stimulate different regions of the brain by adjusting the position and orientation of the larger coil on the head. We have calculated magnetic and electric fields inside a MRI-derived heterogeneous head model for various positions and orientations of the coil. We have also investigated the mechanical and thermal stability of the adjustable "Halo coil" configuration for various positions and orientations of the coil to ensure safe operation of the system.

  19. Measurement of a Conduction Cooled Nb3Sn Racetrack Coil

    Science.gov (United States)

    Kim, HS; Kovacs, C.; Rochester, J.; Sumption, MD; Tomsic, M.; Peng, X.; Doll, D.

    2017-12-01

    Use of superconducting coils for wind turbines and electric aircraft is of interest because of the potential for high power density and weight reduction. Here we test a racetrack coil developed as a proof-of-concept for cryogen-free superconducting motors and generators. The coil was wound with 1209 m of 0.7-mm-diameter insulated tube-type Nb3Sn wire. The coil was epoxy-impregnated, instrumented, covered with numerous layers of aluminized mylar insulation, and inserted vertically into a dewar. The system was cooled to 4.2 K, and a few inches of liquid helium was allowed to collect at the bottom of the dewar but below the coil. The coil was cooled by conduction via copper cooling bars were attached to the coil but also were immersed in the liquid helium at their lower ends. Several current tests were performed on the coil, initially in voltage mode, and one run in current mode. The maximum coil Ic at 4.2 K was 480 A, generating 3.06 T at the surface of the coil. The coil met the design targets with a noticeable margin.

  20. Spontaneous quenches of a high temperature superconducting pancake coil

    Energy Technology Data Exchange (ETDEWEB)

    Lue, J.W.; Lubell, M.S. [Oak Ridge National Lab., TN (United States); Aized, D.; Campbell, J.M.; Schwall, R.E. [American Superconductor Corp., Westborough, MA (United States)

    1995-09-01

    A double-pancake coil made of Bi-2223/Ag high temperature superconducting (HTS) tape was constructed with an embedded heater and graded conductors to study the stability and quench propagation in HTS coils. The experiments were performed with liquid nitrogen and gaseous helium cooling in temperatures ranging from 5 to 77 K. The coil was very stable, and no ``normal`` zone was sustained or propagated with local pulsed heating. However, spontaneous quenches of the cod were experienced. This was found to be the result of having the coil current higher than that of the lower I{sub c} sections of the coil for a long time. This quench process took minutes to develop--much longer than would be expected in a low temperature superconducting coil. The quench behaved more like a spreading and continuous heating of an increasingly larger partially resistive section of the coil than like a sequential ``normal`` front propagation.

  1. Design of a dynamic transcranial magnetic stimulation coil system.

    Science.gov (United States)

    Ge, Sheng; Jiang, Ruoli; Wang, Ruimin; Chen, Ji

    2014-08-01

    To study the brain activity at the whole-head range, transcranial magnetic stimulation (TMS) researchers need to investigate brain activity over the whole head at multiple locations. In the past, this has been accomplished with multiple single TMS coils that achieve quasi whole-head array stimulation. However, these designs have low resolution and are difficult to position and control over the skull. In this study, we propose a new dynamic whole-head TMS mesh coil system. This system was constructed using several sagittal and coronal directional wires. Using both simulation and real experimental data, we show that by varying the current direction and strength of each wire, this new coil system can form both circular coils or figure-eight coils that have the same features as traditional TMS coils. Further, our new system is superior to current coil systems because stimulation parameters such as size, type, location, and timing of stimulation can be dynamically controlled within a single experiment.

  2. New technique for wiring SSC superconducting sextupole corrector coils

    International Nuclear Information System (INIS)

    Leon, B.

    1985-01-01

    There exists in the electronics industry, a technology for the manufacture of printed circuit (PC) boards which is directly transferable into the creation of highly controlled coils, such as the SSC sextupole superconducting corrector coils. This technology, which uses a process of laying down insulated wire in highly controlled patterns has heretofore been confined exclusively to the manufacture of high density printed circuit (PC) boards, possibly due to an ignorance of its utility in the field of precision winding of coils. This ability to fix wires in a well defined location can be used to produce precision wound coils in a very cost-effective manner. These coils may be superior in quality to conventionally made coils. Before describing what can be created with this technology, it is necessary to take a look at this coil winding process, the MULTIWIRE process, and the industry which has utilized this technology

  3. A new technique for wiring SSC superconducting sextupole corrector coils

    International Nuclear Information System (INIS)

    Leon, B.

    1985-01-01

    There exists in the electronics industry, a technology for the manufacture of printed circuit (PC) boards which is directly transferable into the creation of highly controlled coils, such as the SSC sextupole superconducting corrector coils. This technology, which uses a process of laying down insulated wire in highly controlled patterns, has heretofore been confined excusively to the manufacture of high density printed circuit (PC) boards, possibly due to an ignorance of its utility in the field of precision winding of coils. This ability to fix wires in a well defined location can be used to produce precision wound coils in a very cost-effective manner. These coils may be superior in quality to conventionally made coils. Before describing what can be created with this technology, it is necessary to take a look at this coil winding process, the MULTIWIRE process, and the industry which has utilized this technology

  4. Coil irrigation in sugar cane (Saccharum officinarum

    Directory of Open Access Journals (Sweden)

    Jesús Sánchez Gutiérrez

    2016-01-01

    Full Text Available This study was made at the Basic Seed Bank of the Local Sugar Cane Research Station for the Mideastern Cuba, based in Camaguey, on brown carbonate soil, between 2013 and 12014. Coil irrigation was applied to meet the water requirements for the crop, according to the edafoclimatic conditions and the different phenological phases it has. The Savo method was used to determine useful rain water. Adjustment and complementation of the irrigation program was based on indicators that characterize the exploitation scheme. The machine´s working parameters were determined to meet the water needs, and increase crop´s overall yields. The evaluations and results achieved have contributed to new proposals for management and operation of coil irrigation, and they are important to increase its efficiency.

  5. Voice coil based scanning probe microscopy

    Czech Academy of Sciences Publication Activity Database

    Klapetek, P.; Valtr, M.; Duchoň, V.; Sobota, Jaroslav

    2012-01-01

    Roč. 7, č. 6 (2012), 332:1-7 ISSN 1931-7573 R&D Projects: GA MPO FR-TI1/241; GA AV ČR KAN311610701; GA MŠk ED0017/01/01 Institutional support: RVO:68081731 Keywords : SPM * Voice coil * Interferometry Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 2.524, year: 2012

  6. Coil irrigation in sugar cane (Saccharum officinarum)

    OpenAIRE

    Jesús Sánchez Gutiérrez; Yoslén Fernández Gálvez; Mayra Martínez Pírez; Camilo Bonet Pérez; Manuel A Hernández Victoria; Arlandy Noy Perera

    2016-01-01

    This study was made at the Basic Seed Bank of the Local Sugar Cane Research Station for the Mideastern Cuba, based in Camaguey, on brown carbonate soil, between 2013 and 12014. Coil irrigation was applied to meet the water requirements for the crop, according to the edafoclimatic conditions and the different phenological phases it has. The Savo method was used to determine useful rain water. Adjustment and complementation of the irrigation program was based on indicators that characterize the...

  7. Acute lung injury following refrigeration coil deicing.

    Science.gov (United States)

    McKeown, Nathanael J; Burton, Brent T

    2012-03-01

    We report a case of a worker who developed ALI requiring mechanical ventilatory support after attempting to melt ice condensate by applying the flame of an oxy-acetylene torch to refrigeration coils charged with a halocarbon refrigerant in a closed environment. A discussion of possible etiologies are discussed, including phosgene, carbonyl fluoride, and nitrogen oxides. Primary prevention with adequate respiratory protection is recommended whenever deicing is performed in a closed space environment.

  8. A new moving-coil microelectrode puller.

    Science.gov (United States)

    Ensor, D R

    1979-03-01

    This paper describes an improved electrode puller for the manufacture of glass microelectrodes or micropipettes. The instrument resembles a conventional horizontal two-stage, solenoid-powered electrode puller but the pull is now developed by a light moving-coil and a fixed permanent magnet, using the principle of the moving-coil loudspeaker. In a conventional puller the force is generated by a solenoid with a massive moving-iron core. In this new puller the moving-coil solenoid responds much more rapidly to changing currents because of its greatly reduced inductance, and a substantial reduction in mass to 25 g, gives more acceleration from a comparable force. The sudden discharge of a capacitor bank through the coil accelerates the glass quickly during the last stage of the pull. This rapid acceleration is of importance in the formation of good electrodes with fine tips. For the prototype, an electronic control unit was constructed which allows the parameters necessary for the manufacture of electrodes to be set and regulated accurately and repeatedly, so that series of electrodes of constant shapes can be made. The length of the electrode shank may be predetermined over a wide range and tip diameters down to 0.08 micron have already been measured. The angle of the taper that supports the tip may be varied from less than 1 to over 6 degrees. The mechanical design of the instrument is comparatively simple, as it has only one moving part, while the relative complexity of the electronic control section should not present any manufacturing difficulties. Although this puller has been used mainly to make single-barrel fine electrodes from borosilicate glass, it is adaptable for other purposes. The extent of the control over the shape of the shank of the electrode renders it particularly suitable for the manufacture of composite, ion-sensitive electrodes.

  9. Single coil bistable, bidirectional micromechanical actuator

    Science.gov (United States)

    Tabat, Ned; Guckel, Henry

    1998-09-15

    Micromechanical actuators capable of bidirectional and bistable operation can be formed on substrates using lithographic processing techniques. Bistable operation of the microactuator is obtained using a single coil and a magnetic core with a gap. A plunger having two magnetic heads is supported for back and forth linear movement with respect to the gap in the magnetic core, and is spring biased to a neutral position in which the two heads are on each side of the gap in the core. The single electrical coil is coupled to the core and is provided with electrical current to attract one of the heads toward the core by reluctance action to drive the plunger to a limit of travel in one direction. The current is then cut off and the plunger returns by spring action toward the gap, whereafter the current is reapplied to the coil to attract the other head of the plunger by reluctance action to drive the plunger to its other limit of travel. This process can be repeated at a time when switching of the actuator is required.

  10. Transcatheter coil embolisation of pulmonary arteriovenous malformations

    International Nuclear Information System (INIS)

    Wingen, M.; Guenther, R.W.

    2001-01-01

    Evaluation of technical success, complications and long-term results of transcatheter coil embolisation in pulmonary arteriovenous malformations (pAVMs). Material and Methods: Transcatheter embolisations of 46 pAVMs in 14 patients were analysed retrospectively, and, 5 years after treatment, the patients were interviewed by telefone concerning persistent symptoms and complications. Main symptoms before embolisation were dyspnoe (86%), hypoxaemia (100%), cerebral ischemia (21%), and hemoptysis (14%); 11 patients (79%) suffered from hereditary hemorrhagic telangiectasia. Results: Embolisation with an average of 3,9 coils (min. 1, max. 19 coils) per pAVM yielded technical success in all cases. Only two minor complications, transitory pleuritis and a small lung infarction were observed. On follow up examination after 5 years either no residual complaints or substantial improvement of dyspnoe were reported; no patient suffered from neurologic or hemorrhagic complications after the embolisation. Conclusion: Transcatheter embolisation is a safe and minimally invasive therapy for pAVMs and has rightfully replaced surgical resection as the therapy of choice. (orig.) [de

  11. Carbon footprint of automotive ignition coil

    Science.gov (United States)

    Chang, Huey-Ling; Chen, Chih-Ming; Sun, Chin-Huang; Lin, Hung-Di

    2015-07-01

    In recent years, environmental issues, such as climate change and global warming due to the excessive development of industry, have attracted increasing attention of citizens worldwide. It is known that CO2 accounts for the largest proportion of greenhouse gases. Therefore, how to reduce CO2 emissions during the life cycle of a product to lessen its impact on environment is an important topic in the industrial society. Furthermore, it is also of great significance to cut down the required energy so as to lower its production costs during the manufacturing process nowadays. This study presents the carbon footprint of an automotive ignition coil and its partial materials are defined to explore their carbon emissions and environmental impact. The model IPCC GWP100a calculates potential global greenhouse effect by converting them into CO2 equivalents. In this way, the overall carbon footprint of an ignition coil can be explored. By using IPCC GWP100a, the results display that the shell has the most carbon emissions. The results can help the industry reduce the carbon emissions of an ignition coil product.

  12. Improvements in or relating to superconductive coils

    International Nuclear Information System (INIS)

    Good, J.A.

    1976-01-01

    The windings of a superconducting coil may operate under great stress and movement of the conductors under this stress results in energy dissipation and since specific heats are small at the low temperatures required to induce superconductivity the resultant temperature rise may be sufficient to cause the superconducting properties of the conductor to be impaired. The usual solution to the problem is to employ substantial quantities of normal material in parallel with the superconductor to minimise such effects, but such coils are cumbersome and expensive to produce and operate, and are not suitable for generating intense field gradients. It has been proposed, as an alternative solution, to construct the winding so rigidly as to prevent the movement occurring. Simple potting in an epoxy resin is too brittle to withstand the large stresses. Another proposal involves glass fibre interleaving between layers of winding and then potting in epoxy resin, but this is not very satisfactory. In the arrangement described the winding is wrapped in at least one yard of glass fibre wound helically and the whole is impregnated with epoxy resin. A method for producing such a coil is described. (U.K.)

  13. Vitrectomy combined with periocular/intravitreal injection of steroids for rhegmatogenous retinal detachment associated with choroidal detachment.

    Science.gov (United States)

    Wei, Yong; Wang, Ningli; Chen, Fenghua; Wang, Huaizhou; Bi, Chuncao; Zu, Zhongqiao; Yang, Xingguang

    2014-01-01

    To study the anatomical outcome of rhegmatogenous retinal detachment combined with choroidal detachment after pars plana vitrectomy with periocular/intravitreal injection of steroids. Seventy-seven eyes that have rhegmatogenous retinal detachment combined with choroidal detachment were treated by pars plana vitrectomy with oral prednisolone (Group A) or periocular/intravitreal injection of steroids (Group B) and then divided into 5 subgroups according to different intraocular tamponade agents; Group A1: oral steroids and silicone oil, Group A2: oral steroids and C(3)F(8), Group B1: periocular/intravitreal steroid injections and silicone oil, Group B2: periocular steroid injection and silicone oil, and Group B3: periocular steroid injection and C(3)F(8). Anatomical reattachment of the retina was measured at 12 months after surgery. There was no significant difference in retinal reattachment rate between eyes in Group A and eyes in Group B (77.4% vs. 73.9%, P = 0.726). The retinal reattachment rates were 83.3% in Group A1, 69.2% in Group A2, 82.4% in Group B1, 73.3% in Group B2, and 64.3% in Group B3. There was no statistical difference in the retinal reattachment rates between any of the groups. For the treatment of rhegmatogenous retinal detachment combined with choroidal detachment, pars plana vitrectomy with periocular/intravitreal corticosteroids was comparable in reattachment rate to pars plana vitrectomy with systemic steroids, suggesting an acceptable alternative for patients with this condition who cannot tolerate systemic steroids.

  14. Design and testing of a coil-unit barrel for helical coil electromagnetic launcher

    Science.gov (United States)

    Yang, Dong; Liu, Zhenxiang; Shu, Ting; Yang, Lijia; Ouyang, Jianming

    2018-01-01

    A coil-unit barrel for a helical coil electromagnetic launcher is described. It provides better features of high structural strength and flexible adjustability. It is convenient to replace the damaged coil units and easy to adjust the number of turns in the stator coils due to the modular design. In our experiments, the highest velocity measured for a 4.5-kg projectile is 47.3 m/s and the mechanical reinforcement of the launcher could bear 35 kA peak current. The relationship between the energy conversion efficiency and the inductance gradient of the launcher is also studied. In the region of low inductance gradient, the efficiency is positively correlated with the inductance gradient. However, in the region of high inductance gradient, the inter-turn arc erosion becomes a major problem of limiting the efficiency and velocity of the launcher. This modular barrel allows further studies in the inter-turn arc and the variable inductance gradient helical coil launcher.

  15. Moving-table MR angiography of the peripheral runoff vessels: comparison of body coil and dedicated phased array coil systems.

    Science.gov (United States)

    Huber, A; Scheidler, J; Wintersperger, B; Baur, A; Schmidt, M; Requardt, M; Holzknecht, N; Helmberger, T; Billing, A; Reiser, M

    2003-05-01

    The aim of our study was to compare the signal-to-noise ratio and the diagnostic accuracy of moving-table MR angiography of the peripheral arteries with body coil and dedicated phased array coil systems. Forty patients were examined with digital subtraction angiography and moving-table MR angiography with a 1.5-T MR imaging system either with a body coil (n = 20) or with a dedicated phased array coil (n = 20). The timing of contrast material was performed with real-time MR fluoroscopy. For the iliac artery, upper leg, and lower leg, the mean values for signal-to-noise ratios were 56, 51, and 17, respectively, for the body coil, and 54, 74, and 64, respectively, for the dedicated phased array coil. For the body coil, sensitivity and specificity in identifying stenosis greater than 50% and occlusions were 100% and 96%, respectively, for the iliac arteries, and 100% and 96%, respectively, for the upper leg. For the dedicated phased array coil, sensitivity and specificity for stenosis greater than 50% and occlusions were 100% and 96%, respectively, for the iliac arteries, and 100% and 98%, respectively, for the upper leg. Sensitivity and specificity were inferior for the body coil (88% and 85%) compared with the dedicated phased array coil (100% and 96%) in the lower leg. A significant difference of the mean values of contrast-to-noise ratio was found before and after subtraction for the dedicated phased array coil and body-coil techniques (Student's t test, p coil, the dedicated peripheral phased array surface coil system improves signal-to-noise ratio for the upper and lower leg and diagnostic accuracy in the lower leg.

  16. Synthesis and functionalization of coiled carbon filaments

    Science.gov (United States)

    Hikita, Muneaki

    Coiled carbon filaments have one of the most attractive three-dimensional forms in carbon materials due to their helical morphologies. Because of their shape and carbon structure, they exhibit excellent mechanical and electrical properties such as superelasticity, low Young's modulus, relatively high electrical conductivity, and good electromagnetic (EM) wave absorption. Therefore, they are good candidates as fillers in composite materials for tactile sensor and electromagnetic interference shielding. In medical areas of interests, coiled carbon filaments can be used as micro and nano heaters or trigger for thermotherapy and biosensors using EM wave exposure because absorbed EM waves by coiled carbon filaments are converted into heat. Although various shapes of coiled carbon filaments have been discovered, optimum synthesis conditions and growth mechanisms of coiled carbon filaments are poorly understood. The study of growth kinetics is significant not only to analyze catalyst activity but also to establish the growth mechanisms of coiled carbon filaments. The establishment of growth mechanisms would be useful for determining optimum synthesis conditions and maximizing the quantity of carbon filaments synthesized for a given application. In the first study, tip grown single helical carbon filaments or carbon nanocoils (CNCs) were synthesized by a chemical vapor deposition method using tin-iron-oxide (Sn-Fe-O) xerogel film catalyst. The Sn-Fe-O catalyst was prepared by a low-cost sol-gel method using stannous acetate and ferric acetate as precursors. The growth kinetics of CNCs were monitored by a thermogravimetric analyzer, and the experimental result was correlated using a one-dimensional kinetic model, corresponding to one-dimensional tip growth. In the second study, bidirectionally grown double helical filaments or carbon microcoils (CMCs) were synthesized using a chemical vapor deposition method. CMCs obtained at two reaction temperatures were compared. CMCs

  17. Detached Eddy Simulations of an Airfoil in Turbulent Inflow

    DEFF Research Database (Denmark)

    Gilling, Lasse; Sørensen, Niels; Davidson, Lars

    2009-01-01

    The effect of resolving inflow turbulence in detached eddy simulations of airfoil flows is studied. Synthetic turbulence is used for inflow boundary condition. The generated turbulence fields are shown to decay according to experimental data as they are convected through the domain with the free ...

  18. Numerical simulation of breakup and detachment of an axially ...

    Indian Academy of Sciences (India)

    It is found that the liquid bridge detachment is strongly influenced by the contact angle prescribed at the stationary and moving solid surfaces. At relatively small pulling speeds, the entire liquid is found to preferentially adhere to the less hydrophobic surface.When the prescribed contact angles are equal, however, the liquid ...

  19. Effect of detachment time of pineapple ( Ananas comosus L .) crown ...

    African Journals Online (AJOL)

    A limiting factor to large scale production of pineapple is the scarcity of planting materials. The use of pineapple crown as a propagation material is common, but with no regard to length of time after detachment. A study was conducted in the late seasons of 2007 and 2008 at the Teaching and Research Farm Ekiti State ...

  20. Functional and environmental design of detached, low crest level breakwaters

    International Nuclear Information System (INIS)

    Bricio Garberi, L.; Negro Valdecantos, V.; Diez Gonzalez, J. J.; Lopez Gutierrez, J. S.

    2010-01-01

    The research work as presented in this article covers the design of detached breakwaters since they constitute a type of coastal defense work with which to combat many of the erosion problems found on beaches in a stable, sustainable fashion. The main aim of this work is to formulate a functional and environmental (non structural) method of design enabling the fundamental characteristics of a detached breakwater to be defined as a function of the effect it is wished to induce on the coast whilst meeting social demands and preserving or improving the quality of the littoral environment. The general applicability of the method is also sought by means of considering relations between variables od different natures (climatic, geomorphologic and geometric) influencing the changes experienced on the coast after the detached breakwater has been built. The study of the relations between the different variables is carried out on the data from a abase of nineteen actual, existing detached breakwaters on the Spanish Mediterranean coastline and follows a methodology based on the implementation of non-dimensional monomials and on a search for relations of dependency between them. Finally, a discussion on the results obtained lead to a proposal for a design method that uses some of the graphic relations found between the variables studied with which the aforesaid main objective is achieved. (Author) 9 refs.

  1. Bilateral iris, choroid, optic nerve colobomas and retinal detachment ...

    African Journals Online (AJOL)

    Rabah M. Shawky

    2013-12-05

    Dec 5, 2013 ... Bilateral iris, choroid, optic nerve colobomas and retinal detachment in an Egyptian patient with mild Baraitser–Winter syndrome. Rabah M. Shawky *, Heba Salah Abd-Elkhalek Elabd, Radwa Gamal. Pediatric Department, Genetics Unit, Ain Shams University, Egypt. Received 26 October 2013; accepted 4 ...

  2. Atomic collisions: electron detachment and resonant inelastic scattering

    International Nuclear Information System (INIS)

    Ojha, P.C.

    1980-01-01

    Part I: Electron detachment in collisions of negative ions, H - + He. In conflict from the expectation from a compound state model, observation shows that the detachment cross section increases with energy in the adiabatic region below 2 keV. The compound state model is not appropriate because of a strong s-wave component in the wavefunction allows the extra electron to run away as soon as its state becomes unbound. The detachment cross section increases with the collision velocity because detachment is induced by a breakdown of the Born-Oppenheimer approximation which shifts to larger separations of the nuclei as the collision velocity increases. Part II: Resonance excitation in electron rare gas collisions. A new method is proposed for calculating the positions of resonances and cross sections in electron molecule collisions by enclosing the entire system in a spherical box, thus converting the problem to a bound state problem. It is used to calculate the energies of [np 52 P/sub 3/2,1/2/](n + l)s(n + l)p 3 P resonances in collisions of slow electrons with Ne, Ar, Kr, and Xe. The problem is simplified by invoking the Grandparent Model (that the resonances consist of two loosely bound electrons outside a compact positive ion core). The model is tested by explaining the Schulz's Law. Cross sections for excitation of Ne and Ar atoms from the ground state to the lowest metastable and uv emitting levels are calculated

  3. Bilateral orbital infarction and retinal detachment in a previously ...

    African Journals Online (AJOL)

    In this report, we present a case of an 11‑year‑old previously undiagnosed sickle cell disease Nigerian girl with severe acute bilateral orbital infarction and retinal detachment to highlight that hemoglobinopathy induced orbital infarction should be considered in African children with acute onset proptosis with or without ...

  4. Cataract and Retinal Detachment Following Electric Shock Injury in ...

    African Journals Online (AJOL)

    Aim: To report a case of cataract and retinal detachment following an electrical injury in an adult Nigerian male. C a se report: A 28-year-old man presented with a history of progressive and painless loss of vision in the right eye, three years after an electric shock injury. There was no history of mechanical trauma.

  5. Blindness from bilateral bullous retinal detachment: tragedy of a ...

    African Journals Online (AJOL)

    Objective: To present a scourge of blindness possibly due to an inherited condition causing retinal detachment in 3 siblings. Methods: In February 2004, three siblings from a monogamous family from Ipetu-Ijesha in Osun state, Nigerian presented to the author consecutively with history of visual impairment/ blindness.

  6. Incidence and Pattern of Retinal Detachment in a Tertiary Eye ...

    African Journals Online (AJOL)

    giant tears; 6 (6.5%) had dialysis and 3 (3.2%) had coexisting macula holes; in 73.1% the tears were located in the superior retina. Conclusions: Retinal ... factor in 33 (35.5%) patients. In no patient was the detachment restricted to one quadrant. .... Health education of eye patients and the general public on the symptoms of ...

  7. Bilateral Serous Retinal Detachment as a Complication of ...

    African Journals Online (AJOL)

    preeclampsia and eclampsia for ocular manifestations, which should be helpful for obstetrician in the management of patient. disks (ODs), macula, and tortuous retinal vessels. Bilateral exudative retinal detachments (RD) were detected superotemporal and inferotemporal to the. ODs involving the macula [Figures 1 and 2].

  8. Turbulent Simulations of Divertor Detachment Based On BOUT + + Framework

    Science.gov (United States)

    Chen, Bin; Xu, Xueqiao; Xia, Tianyang; Ye, Minyou

    2015-11-01

    China Fusion Engineering Testing Reactor is under conceptual design, acting as a bridge between ITER and DEMO. The detached divertor operation offers great promise for a reduction of heat flux onto divertor target plates for acceptable erosion. Therefore, a density scan is performed via an increase of D2 gas puffing rates in the range of 0 . 0 ~ 5 . 0 ×1023s-1 by using the B2-Eirene/SOLPS 5.0 code package to study the heat flux control and impurity screening property. As the density increases, it shows a gradually change of the divertor operation status, from low-recycling regime to high-recycling regime and finally to detachment. Significant radiation loss inside the confined plasma in the divertor region during detachment leads to strong parallel density and temperature gradients. Based on the SOLPS simulations, BOUT + + simulations will be presented to investigate the stability and turbulent transport under divertor plasma detachment, particularly the strong parallel gradient driven instabilities and enhanced plasma turbulence to spread heat flux over larger surface areas. The correlation between outer mid-plane and divertor turbulence and the related transport will be analyzed. Prepared by LLNL under Contract DE-AC52-07NA27344. LLNL-ABS-675075.

  9. Numerical simulation of breakup and detachment of an axially ...

    Indian Academy of Sciences (India)

    Kishore Singh Patel

    Abstract. The extensional, breakup and detachment dynamics of an axially stretching Newtonian liquid bridge are investigated numerically with a dynamic domain multiphase incompressible flow solver. The mul- tiphase flow solver employs a Cahn–Hilliard phase field model to describe the evolution of the diffuse interface.

  10. Silicone oil removal after rhegmatogenous retinal detachment: comparing techniques

    NARCIS (Netherlands)

    Tan, H. S.; Dell'omo, R.; Mura, M.

    2012-01-01

    Purpose To assess the outcome of silicone oil removal after rhegmatogenous retinal detachment (RRD) surgery, and to compare results of a two-port (infusion-extraction) versus a three-port (full vitrectomy) approach. Methods Primary outcome measure was the rate of redetachment. Secondary outcome

  11. Air versus gas tamponade in retinal detachment surgery

    NARCIS (Netherlands)

    Tan, H. Stevie; Oberstein, Sarit Y. Lesnik; Mura, Marco; Bijl, Heico M.

    2013-01-01

    Objective To compare the outcome of air tamponade with gas tamponade in primary vitrectomy for the treatment of rhegmatogenous retinal detachment (RRD). Methods We examined the records of 524 cases of 523 patients that underwent primary vitrectomy for RRD with air or sulphur hexafluoride 20% gas

  12. Peripheral 360 degrees retinectomy in complex retinal detachment.

    Science.gov (United States)

    Banaee, Touka; Hosseini, Seyyedeh Maryam; Eslampoor, Alireza; Abrishami, Majid; Moosavi, Mirnaghi

    2009-06-01

    To report the functional and anatomical results and complications of 360 degrees peripheral retinectomy for management of complicated retinal detachment. Patients with complicated retinal detachment underwent pars plana vitrectomy, 360 degrees retinectomy, intraoperative endolaser, and internal tamponade with silicone oil. Postoperative visual acuity, intraocular pressure, retinal status, need for reoperation, and complications are presented. Twenty eyes of 19 patients with a mean age of 32.4 years (8-75 years) underwent pars plana vitrectomy and 360 degrees peripheral retinectomy for complicated retinal detachment due to anterior proliferative vitreoretinopathy, unstable edge of retinal break, anterior hyaloidal fibrovascular proliferation, retinal incarceration in scleral wound, and 300 degrees giant retinal tear. Intraoperative reattachment was achieved in 18 eyes. Mean postoperative follow-up time was 24.2 months (2-70 months). Retina was attached in 14 eyes (70%) in the last visit. Eight eyes (40%) had 5/200 or greater visual acuity. Preoperative and postoperative visual acuities did not have significant correlation (Spearman correlation coefficient = 0.291). There was no relation between diagnosis and anatomical outcome (P > 0.2). Relaxing peripheral 360 degrees retinectomy is an effective procedure for flattening the retina in complicated retinal detachments when no other option is available.

  13. Elucidation of the genetic causes of retinal detachment

    NARCIS (Netherlands)

    Go, S.L.

    2006-01-01

    Rhegmatogenous retinal detachment (RRD) is caused by a break in the neurosensory retina of the eye, thereby allowing fluid from the vitreous space into the space between the sensory retina and the retinal pigment epithelium. Untreated, this disorder can lead to blindness. A case-control study in

  14. Bilateral Rhegmatogenous Retinal Detachment during External Beam Radiotherapy

    Directory of Open Access Journals (Sweden)

    Takako Hidaka

    2016-06-01

    Full Text Available Herein, we report a case of nontraumatic bilateral rhegmatogenous retinal detachment (RRD during external beam radiotherapy for nonocular tumor, presented as an observational case study in conjunction with a review of the relevant literature. A 65-year-old male was referred to our hospital due to bilateral RRD. He underwent a biopsy for a tumor of the left frontal lobe 4 months prior to presentation, and the tumor had been diagnosed as primary central nerve system B-cell type lymphoma. He received chemotherapy and external beam radiotherapy for 1 month. There were no traumatic episodes. Bilateral retinal detachment occurred during a series of radiotherapies. Simultaneous nontraumatic bilateral retinal detachment is rare. The effects of radiotherapy on ocular functionality, particularly in cases involving retinal adhesion and vitreous contraction, may include RRD. Thus, it is necessary to closely monitor the eyes of patients undergoing radiotherapy, particularly those undergoing surgery for retinal detachment and those with a history of photocoagulation for retinal tears, a relevant family history, or risk factors known to be associated with RRD.

  15. [Surgical treatment of very advanced rhegmatogenous retinal detachment].

    Science.gov (United States)

    Hejsek, L; Ernest, J; Němec, P; Rejmont, L; Manethová, K; Stepanov, A; Rozsíval, P

    2013-12-01

    Rhegmatogenous retinal detachment is a serious ocular pathology. Therapeutic options are surgical only. Surgery is in advanced stages technically and financially demanding. In this paper, we consider the results operated detachments, which were for their advancement, with respect to the technical possibilities of the present intraocular surgery, on the border of the surgical possibilities. The group consisted of 37 eyes of 37 patients who were followed prospectively and had in the affected eye very advanced (old) rhegmatogenous retinal detachment. As a method to confirtm any visual functions were used visual evoked potentials in flash monocular stimulation (F-VEP). All patients had a cerclage performed 12 mm from the limbus, 20G pars plana vitrectomy (PPV), in 2 was also performed cataract surgery (phacoemulsification with implantation of an artificial intraocular lens to the bag). Surgery was done in 23 of 37 patients (62 % of the whole group), with the remaining 14 eyes was not due to the severity of finding highly advanced retinal detachment. Attached retina at the end of the observation period had 14 eyes (61% of the patients, 38% of the whole group). In 5 eyes was due to local re-detachment in the periphery only stabilized finding (22% of operated eyes, 14% of all). The values ​​of visual acuity in the subgroup of operated eyes were statistically significantly increased after surgery (Wilcoxon p = 0.036). The values ​​of F-VEP were not statistically significantly different between operated and non-operated patients and was not found any statistically significant correlation between the vision (and even after surgery) and F-VEP in operated eyes. Anatomical success of surgical treatment of advanced retinal detachment is possible. But the correlation was not found in visual acuity and F-VEP or the severity of preoperative disturbed visual function, even in the improvement in the postoperative period. F-VEP is not a suitable marker for determining the

  16. Seismic Slip on an Oblique Detachment Fault at Low Angles

    Science.gov (United States)

    Janecke, S. U.; Steely, A. N.; Evans, J. P.

    2008-12-01

    Pseudotachylytes are one of the few accepted indicators of seismic slip along ancient faults. Low-angle normal faults have produced few large earthquakes in historic times and low-angle normal faults (detachment faults) are typically severely misoriented relative to a vertical maximum compressive stress. As a result many geoscientists question whether low-angle normal faults produce earthquakes at low angles. Relationships in southern California show that a major low-angle normal-oblique fault slipped at low angles and produced large earthquakes. The exhumed Late Cenozoic West Salton detachment fault preserves spectacular fault- related pseudotachylytes along its fault plane and injected into its hanging wall and footwall. Composite pseudotachylyte zones are up to 1.25 m thick and persists over lateral distances of at least 10's of meters. Pseudotachylyte is common in most thin sections of damaged fault rocks with more than 20% (by volume) of cataclasite. We recognized the presence of original melt using numerous criteria: abundant spherulites in thin sections, injection structures at both the thin-section and outcrop scale, black aphanitic textures, quenched vein margins, variations in microcrystallite textures and/or size with respect to the vein margin, and glassy textures in hand sample. Multiple earthquakes are inferred to produce the layered "stratigraphy" in some exposures of pseudotachylytes. We infer that the West Salton detachment fault formed and slipped at low angles because it nearly perfectly reactivates a Cretaceous ductile thrust system at the half km scale and dips between 10 and 45 degrees. The about 30 degree NNE dip of the detachment fault on the north side of Yaqui Ridge is likely steeper than its dip during detachment slip because there is local steepening on the flanks of the Yaqui Ridge antiform in a contractional stepover of a crosscutting Quaternary San Felipe dextral fault zone. These relationships indicate a low dip on the detachment

  17. A low cost light diffuser made of metal coil.

    Science.gov (United States)

    Morita, Nozomi; Arai, Tsunenori

    2008-01-01

    We proposed a low cost flexible light diffuser made of metal coil to obtain an appropriate light dose against certain laser therapies in narrow bending organs. We investigated experimentally the diffusion light dose of prototype coils made of stainless steel (sus304). We measured the diffusion light intensity of the prototype coils along the irradiation direction and the circumferential direction with the various pitch distances of the prototype coils and numerical aperture (NA) of laser light beam as the characteristic parameters of the light diffusion. We measured the temperature elevation of the prototype coils to study the waste energy of these prototype coils. The FWHM on the light intensity along the prototype coils marked up to 12.8mm with the constant pitch distance of 0.09 mm and the fiber output light NA of 0.038. The FWHM on the light intensity was improved to 13.7 mm with the composite pitch distance coils of which the pitch distances were 0.09 mm in the proximate and 0.18 mm in the distal. Since the efficiency of the diffusion irradiation against the fiber output was typically 7.7% in the prototype coils of which the surface reflectance was 50%, approximately 90% of the laser light energy was transferred to the temperature elevation. We estimated the practical diffusion efficiency around 75% using the high reflection of the prototype coils surface up to 90%.

  18. Conceptual Design of Alborz Tokamak Poloidal Coils System

    Science.gov (United States)

    Mardani, M.; Amrollahi, R.

    2013-04-01

    The Alborz tokamak is a D-shape cross section tokamak that is under construction in Amirkabir University of Technology. One of the most important parts of tokamak design is the design of the poloidal field system. This part includes the numbers, individual position, currents and number of coil turns of the magnetic field coils. Circular cross section tokamaks have Vertical Field system but since the elongation and triangularity of plasma cross section shaping are important in improving the plasma performance and stability, the poloidal field coils are designed to have a shaped plasma configuration. In this paper the design of vertical field system and the magnetohydrodynamic equilibrium of axisymmetric plasma, as given by the Grad-Shafranov equation will be discussed. The poloidal field coils system consists of 12 circular coils located symmetrically about the equator plane, six inner PF coils and six outer PF coils. Six outer poloidal field coils (PF) are located outside of the toroidal field coils (TF), and six inner poloidal field coils are wound on the inner legs and are located outside of a vacuum vessel.

  19. Transcranial Magnetic Stimulation-coil design with improved focality

    Science.gov (United States)

    Rastogi, P.; Lee, E. G.; Hadimani, R. L.; Jiles, D. C.

    2017-05-01

    Transcranial Magnetic Stimulation (TMS) is a technique for neuromodulation that can be used as a non-invasive therapy for various neurological disorders. In TMS, a time varying magnetic field generated from an electromagnetic coil placed on the scalp is used to induce an electric field inside the brain. TMS coil geometry plays an important role in determining the focality and depth of penetration of the induced electric field responsible for stimulation. Clinicians and basic scientists are interested in stimulating a localized area of the brain, while minimizing the stimulation of surrounding neural networks. In this paper, a novel coil has been proposed, namely Quadruple Butterfly Coil (QBC) with an improved focality over the commercial Figure-8 coil. Finite element simulations were conducted with both the QBC and the conventional Figure-8 coil. The two coil's stimulation profiles were assessed with 50 anatomically realistic MRI derived head models. The coils were positioned on the vertex and the scalp over the dorsolateral prefrontal cortex to stimulate the brain. Computer modeling of the coils has been done to determine the parameters of interest-volume of stimulation, maximum electric field, location of maximum electric field and area of stimulation across all 50 head models for both coils.

  20. Structural analysis of the NET toroidal field coils and conductor

    International Nuclear Information System (INIS)

    Mitchell, N.; Collier, D.; Gori, R.

    1989-01-01

    The NET toroidal field coils will utilise A15-type superconductor at 4.2 K to generate fields up to 11.5 T. The superconductor strands themselves are sensitive to strain, which causes degradation of their current carrying capacity, and thus the detailed behaviour of the coil conductor must be analysied so that the strian can be minimised. This analysis must include the manufacturing processes of the conductor as well as the normal and abnormal loperational loads. The conductor will be insulated and bonded by glass fibre reinforced epoxy resin, with limited bonding shear strength, and the overall support of the complete coil system must be designed to reduce these shear stresses. The coils will be subjected to pulse loads form the poloidal field coils, and analysis of the slip between the various coil components, such as conductors and the coil case, giving rise to frictional heating and possible loss of superconducting properties is another important factor, which has been investigated by a number of stress analyses. The manufacturing, thermal and normal magnetic loads on the coils and the analysis leading to the proposed structural design are described. In addition to the normal operating conditions, there is a range of abnormal load conditions which could result from electrical or mechanical faults on the coils. The effect of these potential faults has been analysed and the coil design modified to prevent catastrophic structural failure. (author). 13 refs.; 8 figs.; 1 tab

  1. Hydrodynamic studies of CNT nanofluids in helical coil heat exchanger

    Science.gov (United States)

    Babita; Sharma, S. K.; Mital Gupta, Shipra; Kumar, Arinjay

    2017-12-01

    Helical coils are extensively used in several industrial processes such as refrigeration systems, chemical reactors, recovery processes etc to accommodate a large heat transfer area within a smaller space. Nanofluids are getting great attention due to their enhanced heat transfer capability. In heat transfer equipments, pressure drop is one of the major factors of consideration for pumping power calculations. So, the present work is aimed to study hydrodynamics of CNT nanofluids in helical coils. In this study, pressure drop characteristics of CNT nanofluid flowing inside horizontal helical coils are investigated experimentally. The helical coil to tube diameter was varied from 11.71 to 27.34 keeping pitch of the helical coil constant. Double distilled water was used as basefluid. SDBS and GA surfactants were added to stablilize CNT nanofluids. The volumetric fraction of CNT nanofluid was varied from 0.003 vol% to 0.051 vol%. From the experimental data, it was analyzed that the friction factor in helical coils is greater than that of straight tubes. Concentration of CNT in nanofluids also has a significant influence on the pressure drop/friction factor of helical coils. At a constant concentration of CNT, decreasing helical coil to tube diameter from 27.24 to 11.71, fanning friction factor of helical coil; f c increases for a constant value of p/d t. This increase in the value of fanning friction factor can be attributed to the secondary flow of CNT nanofluid in helical coils.

  2. Magnetic coil design considerations for functional magnetic stimulation.

    Science.gov (United States)

    Lin, V W; Hsiao, I N; Dhaka, V

    2000-05-01

    Our studies have demonstrated effective stimulation of the bladder, bowel, and expiratory muscles in patients with spinal cord injury using functional magnetic stimulation. However, one limitation of the magnetic coils (MC) is related to their inability to specifically stimulate the target tissue without activation of surrounding tissue. The primary goal of this study was to determine the governing parameters in the MC design, such as coil configuration, diameter, and number of turns in one loop of the coil. By varying these parameters, our approach was to design, construct, and evaluate the induced electric field distributions of two sets of novel MC's. Based on the slinky coil design, the first set of coils was constructed to compare their abilities in generating induced electric fields for focal nerve excitation. The second set of coils was built to determine the effect that changes in two parameters, coil diameter and number of turns in one loop, had on field penetration. The results showed that the slinky coil design produced more focalized stimulation when compared to the planar round coils. The primary-to-secondary peak ratios of the induced electric field from slinky 1 to 5 were 1.00, 2.20, 2.85, 2.62, and 3.54. We also determined that coils with larger diameters had better penetration than those with smaller diameters. Coils with less number of turns in one loop had higher initial field strengths; when compared to coils that had more turns per loop, initial field strengths remained higher as distance from the coil increased. In our attempt to customize MC design according to each functional magnetic stimulation application and patients of different sizes, the parameters of MC explored in this study may facilitate designing an optimal MC for a certain clinical application.

  3. Coil optimisation for transcranial magnetic stimulation in realistic head geometry.

    Science.gov (United States)

    Koponen, Lari M; Nieminen, Jaakko O; Mutanen, Tuomas P; Stenroos, Matti; Ilmoniemi, Risto J

    Transcranial magnetic stimulation (TMS) allows focal, non-invasive stimulation of the cortex. A TMS pulse is inherently weakly coupled to the cortex; thus, magnetic stimulation requires both high current and high voltage to reach sufficient intensity. These requirements limit, for example, the maximum repetition rate and the maximum number of consecutive pulses with the same coil due to the rise of its temperature. To develop methods to optimise, design, and manufacture energy-efficient TMS coils in realistic head geometry with an arbitrary overall coil shape. We derive a semi-analytical integration scheme for computing the magnetic field energy of an arbitrary surface current distribution, compute the electric field induced by this distribution with a boundary element method, and optimise a TMS coil for focal stimulation. Additionally, we introduce a method for manufacturing such a coil by using Litz wire and a coil former machined from polyvinyl chloride. We designed, manufactured, and validated an optimised TMS coil and applied it to brain stimulation. Our simulations indicate that this coil requires less than half the power of a commercial figure-of-eight coil, with a 41% reduction due to the optimised winding geometry and a partial contribution due to our thinner coil former and reduced conductor height. With the optimised coil, the resting motor threshold of abductor pollicis brevis was reached with the capacitor voltage below 600 V and peak current below 3000 A. The described method allows designing practical TMS coils that have considerably higher efficiency than conventional figure-of-eight coils. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Bending of the BST-2 coiled-coil during viral budding.

    Science.gov (United States)

    Ozcan, Kadir A; Berndsen, Christopher E

    2017-11-01

    BST-2/tetherin is a human extracellular transmembrane protein that serves as a host defense factor against HIV-1 and other viruses by inhibiting viral spreading. Structurally, BST-2 is a homo-dimeric coiled-coil that is connected to the host cell membrane by N and C terminal transmembrane anchors. The C-terminal membrane anchor of BST-2 is inserted into the budding virus while the N-terminal membrane anchor remains in the host cell membrane creating a viral tether. The structural mechanism of viral budding and tethering as mediated by BST-2 is not clear. To more fully describe the mechanism of viral tethering, we created a model of BST-2 embedded in a membrane and used steered molecular dynamics to simulate the transition from the host cell membrane associated form to the cell-virus membrane bridging form. We observed that BST-2 did not transition as a rigid structure, but instead bent at positions with a reduced interface between the helices of the coiled-coil. The simulations for the human BST-2 were then compared with simulations on the mouse homolog, which has no apparent weak spots. We observed that the mouse homolog spread the bending across the ectodomain, rather than breaking at discrete points as observed with the human homolog. These simulations support previous biochemical and cellular work suggesting some flexibility in the coiled-coil is necessary for viral tethering, while also highlighting how subtle changes in protein sequence can influence the dynamics and stability of proteins with overall similar structure. © 2017 Wiley Periodicals, Inc.

  5. Coil Migration after Transarterial Coil Embolization of a Splenic Artery Pseudoaneurysm

    Directory of Open Access Journals (Sweden)

    Bezawit D. Tekola

    2013-11-01

    Full Text Available A 48-year-old man with a history of splenic artery pseudoaneurysm requiring transarterial embolization 3 months earlier presented to the emergency department with abdominal pain and fever. Computed tomography showed evidence of embolization coil fragments within the gastrointestinal tract. Upper endoscopy showed a large gastric ulcer with numerous embolization coils extruding into the gastric lumen. The patient underwent partial gastrectomy, distal pancreatectomy and resection of the splenic artery pseudoaneurysm. This case illustrates a rare delayed complication of transarterial embolization of a splenic artery pseudoaneurysm.

  6. Polymer therapeutics with a coiled coil motif targeted against murine BCL1 leukemia

    Czech Academy of Sciences Publication Activity Database

    Pola, Robert; Laga, Richard; Ulbrich, Karel; Sieglová, Irena; Král, Vlastimil; Fábry, Milan; Kabešová, Martina; Kovář, Marek; Pechar, Michal

    2013-01-01

    Roč. 14, č. 3 (2013), s. 881-889 ISSN 1525-7797 R&D Projects: GA ČR GAP301/11/0325; GA AV ČR IAAX00500803 Institutional research plan: CEZ:AV0Z50520514 Institutional support: RVO:61389013 ; RVO:61388971 ; RVO:68378050 Keywords : coiled coil * polymer therapeutics * scFv Subject RIV: CD - Macromolecular Chemistry; EC - Immunology (MBU-M); EB - Genetics ; Molecular Biology (UMG-J) Impact factor: 5.788, year: 2013

  7. Polymer cancerostatics with a coiled coil motif targeted against murine leukemia

    Czech Academy of Sciences Publication Activity Database

    Pechar, Michal; Pola, Robert; Janoušková, Olga; Sieglová, Irena; Král, Vlastimil; Fábry, Milan; Tomalová, Barbora; Kovář, Marek

    2017-01-01

    Roč. 6, 4 (Suppl) (2017), s. 36 ISSN 2325-9604. [International Conference and Exhibition on Nanomedicine and Drug Delivery. 29.05.2017-31.05.2017, Osaka] R&D Projects: GA ČR(CZ) GA16-17207S Institutional support: RVO:61389013 ; RVO:68378050 ; RVO:61388971 Keywords : coiled coil * polymer cancerostatics * active targeting Subject RIV: CD - Macromolecular Chemistry; EC - Immunology (MBU-M) https://www.scitechnol.com/conference-abstracts/scientific-tracks-abstracts/nanodelivery-2017-proceedings.html

  8. Increased glutamate levels in the vitreous of patients with retinal detachment

    NARCIS (Netherlands)

    Diederen, R.; Heij, La E.C.; Deutz, N.E.P.; Kijlstra, A.; Kessels, A.G.H.; Eijk, van H.M.; Liem, A.T.A.; Dieudonne, S.; Hendrikse, F.

    2006-01-01

    Experimental models have implicated glutamate in the irreversible damage to retinal cells following retinal detachment. In this retrospective study we investigated a possible role for glutamate and other amino acid neurotransmitters during clinical rhegmatogenous retinal detachment (RRD). Undiluted

  9. Epidemiologic characteristics of retinal detachment surgery at a specialized unit in Denmark

    DEFF Research Database (Denmark)

    Poulsen, Christina Doefler; Peto, Tunde; Grauslund, Jakob

    2016-01-01

    PURPOSE: To examine the incidence of retinal detachments and to evaluate patient profiles and surgical characteristics. METHODS: Retrospective review of patients operated for primary retinal detachment (RD) and redetachment between 2010 and 2012 at the Department of Ophthalmology, Odense Universi...

  10. Thoracic type Ia endoleak: direct percutaneous coil embolization of the aortic arch at the blood entry site after TEVAR and double-chimney stent-grafts

    International Nuclear Information System (INIS)

    Bangard, Christopher; Franke, Mareike; Maintz, David; Chang, De-Hua; Pfister, Roman; Deppe, Antje-Christin; Matoussevitch, Vladimir

    2014-01-01

    To introduce a novel percutaneous technique to stop blood entry at the lesser aortic arch curvature by coil embolisation in type Ia endoleak after TEVAR. A 61-year-old Marfan patient presented with type Ia endoleak of the aortic arch and a growing aortic arch pseudoaneurysm after TEVAR. Multiple preceding operations and interventions made an endovascular approach unsuccessful. Direct percutaneous puncture of the aneurysmal sac would have cured the sign, but not the cause of blood entry at the lesser curvature of the aortic arch. Direct CT-guided percutaneous puncture of the blood entry site in the aortic arch with fluoroscopically guided coil embolisation using detachable extra-long coils was successfully performed. Three weeks after the intervention, the patient developed fever because of superinfection of the pseudoaneurysm. The blood cultures and CT-guided mediastinal aspirate were sterile. After intravenous administration of antibiotics, the fever disappeared and the patient recovered. Six-month follow-up showed permanent closure of the endoleak and a shrinking aneurysmal sac. Direct percutaneous puncture of the aortic arch at the blood entry site of a thoracic type Ia endoleak after TEVAR and double-chimney stent-grafts with coil embolisation of the wedge-shaped space between the lesser aortic curvature and the stent-graft is possible. (orig.)

  11. The heterotrimeric laminin coiled-coil domain exerts anti-adhesive effects and induces a pro-invasive phenotype.

    Directory of Open Access Journals (Sweden)

    Patricia Santos-Valle

    Full Text Available Laminins are large heterotrimeric cross-shaped extracellular matrix glycoproteins with terminal globular domains and a coiled-coil region through which the three chains are assembled and covalently linked. Laminins are key components of basement membranes, and they serve as attachment sites for cell adhesion, migration and proliferation. In this work, we produced a recombinant fragment comprising the entire laminin coiled-coil of the α1-, β1-, and γ1-chains that assemble into a stable heterotrimeric coiled-coil structure independently of the rest of the molecule. This domain was biologically active and not only failed to serve as a substrate for cell attachment, spreading and focal adhesion formation but also inhibited cell adhesion to laminin when added to cells in a soluble form at the time of seeding. Furthermore, gene array expression profiling in cells cultured in the presence of the laminin coiled-coil domain revealed up-regulation of genes involved in cell motility and invasion. These findings were confirmed by real-time quantitative PCR and zymography assays. In conclusion, this study shows for the first time that the laminin coiled-coil domain displays anti-adhesive functions and has potential implications for cell migration during matrix remodeling.

  12. Crystal Structure of the Central Coiled-Coil Domain from Human Liprin-β2†,‡

    Science.gov (United States)

    Stafford, Ryan L.; Tang, Ming-Yun; Sawaya, Michael R.; Phillips, Martin L.; Bowie, James U.

    2011-01-01

    Liprins are a conserved family of scaffolding proteins important for the proper regulation and development of neuronal synapses. Humans have four liprin-αs and two liprin-βs which all contain long coiled-coil domains followed by three tandem SAM domains. Complex interactions between the coiled-coil and SAM domains are thought to create liprin scaffolds, but the structural and biochemical properties of these domains remain largely uncharacterized. In this study we find that the human liprin-β2 coiled-coil forms an extended dimer. Several protease-resistant sub-domains within the liprin-β1 and liprin-β2 coiled-coils were also identified. A 2.0 Å crystal structure of the central, protease-resistant core of the liprin-β2 coiled-coil reveals a parallel helix orientation. These studies represent an initial step towards determining the overall architecture of liprin scaffolds and understanding the molecular basis for their synaptic functions. PMID:21462929

  13. Comparison of the association of sac growth and coil compaction with recurrence in coil embolized cerebral aneurysms.

    Directory of Open Access Journals (Sweden)

    Anna L Hoppe

    Full Text Available In recurrent cerebral aneurysms treated by coil embolization, coil compaction is regarded as the presumptive mechanism. We test the hypothesis that aneurysm growth is the primary recurrence mechanism. We also test the hypothesis that the coil mass will translate a measurable extent when recurrence occurs.An objective, quantitative image analysis protocol was developed to determine the volumes of aneurysms and coil masses during initial and follow-up visits from 3D rotational angiograms. The population consisted of 15 recurrence and 12 non-recurrence control aneurysms initially completely coiled at a single center. An investigator sensitivity study was performed to assess the objectivity of the methods. Paired Wilcoxon tests (p<0.05, one-tailed were performed to assess for aneurysm and coil growth. The translation of the coil mass center at follow-up was computed. A Mann Whitney U-Test (p<0.05, one-tailed was used to compare translation of coil mass centers between recurrence and control subjects.Image analysis protocol was found to be insensitive to the investigator. Aneurysm growth was evident in the recurrence cohort (p=0.003 but not the control (p=0.136. There was no evidence of coil compaction in either the recurrence or control cohorts (recurrence: p=0.339; control: p=0.429. The translation of the coil mass centers was found to be significantly larger in the recurrence cohort than the control cohort (p=0.047.Aneurysm sac growth, not coil compaction, was the primary mechanism of recurrence following successful coil embolization. The coil mass likely translates to a measurable extent when recurrence occurs and has the potential to serve as a non-angiographic recurrence marker.

  14. Apical atrophy of retinal pigment epithelial detachments in central serous chorioretinopathy

    DEFF Research Database (Denmark)

    Pryds, Anders; Hamann, Steffen; Larsen, Michael

    2012-01-01

    compatible with CSC. RESULTS: A juxtafoveal retinal pigment epithelial detachment with apical atrophy of the retinal pigment epithelium with corresponding severe attenuation of the pigmentation of the retinal pigment epithelium was observed in both patients. One of the patients presented with a serous...... neurosensory retinal detachment with smokestack leakage 7 years after first being seen. The other patient was never seen with a neurosensory detachment. CONCLUSION: Isolated pigment epithelial detachment with apical retinal pigment epithelial atrophy may represent a precursor stage of CSC....

  15. An automated coil winding machine for the SSC dipole magnets

    International Nuclear Information System (INIS)

    Kamiya, S.; Iwase, T.; Inoue, I.; Fukui, I.; Ishida, K.; Kashiwagi, S.; Sato, Y.; Yoshihara, T.; Yamamoto, S.; Johnson, E.; Gibson, C.

    1990-01-01

    The authors have finished the preliminary design of a fully automated coil winding machine that can be used to manufacture the large number of SSC dipole magnets. The machine aims to perform all coil winding operations including coil parts inserting without human operators at a high productive rate. The machine is composed of five industrial robots. In order to verify the design, they built a small winding machine using an industrial robot and successfully wound a 1 meter long coil using SSC dipole magnet wire. The basic design for the full length coil and the robot winding technique are described in this paper. A fully automated coil winding machine using standard industrial components would be very useful if duplicate production lines are used. 5 figs., 1 tab

  16. Ferrite core non-linearity in coils for magnetic neurostimulation.

    Science.gov (United States)

    RamRakhyani, Anil Kumar; Lazzi, Gianluca

    2014-10-01

    The need to correctly predict the voltage across terminals of mm-sized coils, with ferrite core, to be employed for magnetic stimulation of the peripheral neural system is the motivation for this work. In such applications, which rely on a capacitive discharge on the coil to realise a transient voltage curve of duration and strength suitable for neural stimulation, the correct modelling of the non-linearity of the ferrite core is critical. A demonstration of how a finite-difference model of the considered coils, which include a model of the current-controlled inductance in the coil, can be used to correctly predict the time-domain voltage waveforms across the terminals of a test coil is presented. Five coils of different dimensions, loaded with ferrite cores, have been fabricated and tested: the measured magnitude and width of the induced pulse are within 10% of simulated values.

  17. New method to design stellarator coils without the winding surface

    Science.gov (United States)

    Zhu, Caoxiang; Hudson, Stuart R.; Song, Yuntao; Wan, Yuanxi

    2018-01-01

    Finding an easy-to-build coils set has been a critical issue for stellarator design for decades. Conventional approaches assume a toroidal ‘winding’ surface, but a poorly chosen winding surface can unnecessarily constrain the coil optimization algorithm, This article presents a new method to design coils for stellarators. Each discrete coil is represented as an arbitrary, closed, one-dimensional curve embedded in three-dimensional space. A target function to be minimized that includes both physical requirements and engineering constraints is constructed. The derivatives of the target function with respect to the parameters describing the coil geometries and currents are calculated analytically. A numerical code, named flexible optimized coils using space curves (FOCUS), has been developed. Applications to a simple stellarator configuration, W7-X and LHD vacuum fields are presented.

  18. Electromagnetic results of the Japanese LCT coil's domestic test

    International Nuclear Information System (INIS)

    Nishi, Masataka; Okuno, Kiyoshi; Takahashi, Yoshikazu; Tsuji, Hiroshi; Ando, Toshinari; Shimamoto, Susumu

    1984-01-01

    The domestic test of the Japanese LCT coil was carried out in 1982. During this test, the coil was charged up to the single coil's 100% state (10.22kA, 6.4T, 106MJ) four times and experienced no quenche. at the 100% charging state, coil stability was tested by using heaters installed in the conductor. A half turn length normal zone (about 5 m) generated by heaters was spontenously disappeared in 2 second. This normalized zone included the highest magnetic field position. The transport current which gives the stable limit is extraporated to be about 12.5kA at 8T by this test result. The dump test was carried out also from the 100% charging state. At that time, about 90% of the coil's stored energy was extracted by the dump resistor and the coil was not damaged. (author)

  19. Poloidal field coil stress analysis for the ZTH machine

    International Nuclear Information System (INIS)

    Girrens, S.P.; Bennett, J.G.; Murphy, D.M.

    1988-02-01

    Three-dimensional finite element analysis of representative equilibrium field and ohmic heating coils for the Los Alamos ZTH air core machine was performed to determine static stress levels developed within the coil structure caused by Lorentz-force loading. Because of the complex coil configuration in cross section (copper conductors embedded in an epoxy insulating matrix), the study was performed in three steps: a bulk orthotropic material property determination, a bulk material coil section analysis, and a detailed composite cross section of selected thickness analysis. Computational procedures used with coil stress and displacement results that were obtained are presented. Extensive work was performed to investigate the magnitude of the error in coil stress predictions arising from the use of the three-step analysis procedure. Analytical and numerical procedures used to perform the estimate of error study are also presented. 34 figs

  20. General Atomic's superconducting toroidal field coil concept

    International Nuclear Information System (INIS)

    Alcorn, J.; Purcell, J.

    1978-01-01

    General Atomic's concept for a superconducting toroidal field coil is presented. The concept is generic for large tokamak devices, while a specific design is indicated for a 3.8 meter (major radius) ignition/burn machine. The concept utilizes bath cooled NbTi conductor to generate a peak field of 10 tesla at 4.2 K. The design is simple and straightforward, requires a minimum of developmental effort, and draws extensively upon the perspective of past experience in the design and construction of large superconducting magnets for high energy physics. Thus, the primary emphasis is upon economy, reliability, and expeditious construction scheduling. (author)

  1. A large stellarator based on modular coils

    International Nuclear Information System (INIS)

    Hamberger, S.M.; Sharp, L.E.; Petersen, L.F.

    1979-06-01

    Although stellarators offer some considerable advantages over tokamaks, difficulties arise in designing large devices due, for instance, to poor plasma access as well as to constructional electromechanical and maintenance problems associated with continous helical windings. This paper describes a design for a fairly large device (major radius 2.1m), based on a set of discrete coil modules arranged in a toroidal configuration to provide the required closed magnetic surfaces, having gaps for unobstructed access to the plasma for diagnostics, etc, and allowing for easy removal for maintenance

  2. Sound Coiled-Tubing Drilling Practices

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Thomas; Deskins, Greg (Maurer Technology Inc.); Ward, Stephen L. (Advantage Energy Services Ltd); Hightower, Mel

    2001-09-30

    This Coiled-Tubing Drilling (CTD) Sound Practices Manual provides tools needed by CTD engineers and supervisors to plan, design and perform safe, successful CTD operations. As emphasized throughout, both careful planning and attention to detail are mandatory for success. A bibliography of many useful CTD references is presented in Chapter 6. This manual is organized according to three processes: 1) Pre-Job Planning Process, 2) Operations Execution Process, and 3) Post-Job Review Process. Each is discussed in a logical and sequential format.

  3. Analytical solutions to SSC coil end design

    International Nuclear Information System (INIS)

    Bossert, R.C.; Brandt, J.S.; Carson, J.A.; Fulton, H.J.; Lee, G.C.; Cook, J.M.

    1989-03-01

    As part of the SCC magnet effort, Fermilab will build and test a series of one meter model SSC magnets. The coils in these magnets will be constructed with several different end configurations. These end designs must satisfy both mechanical and magnetic criteria. Only the mechanical problem will be addressed. Solutions will attempt to minimize stresses and provide internal support for the cable. Different end designs will be compared in an attempt to determine which is most appropriate for the SSC dipole. The mathematics required to create each end configuration will be described. The computer aided design, programming and machine technology needed to make the parts will be reviewed. 2 refs., 10 figs

  4. Cyclic GMP in the pig vitreous and retina after experimental retinal detachment

    NARCIS (Netherlands)

    Diederen, R.; Heij, La E.C.; Lemmens, M.A.M.; Kijlstra, A.; Vente, De J.; Hendrikse, F.

    2008-01-01

    Purpose: Earlier studies have revealed a decreased level of cGMP in vitreous fluid obtained from patients with a retinal detachment. To further investigate this phenomenon, we developed an experimental retinal detachment model in pigs. Methods: Experimental unilateral retinal detachments were

  5. Characteristics of rhegmatogenous retinal detachment and their relationship to success rates of surgery.

    Science.gov (United States)

    Williamson, Tom H; Lee, Edward J K; Shunmugam, Manoharan

    2014-07-01

    To determine features of rhegmatogenous retinal detachment predictive of anatomical success with surgical procedure. All patients undergoing surgery at a tertiary referral practice had contemporaneous data collection in an electronic database. Overall, 847 eyes from 847 patients undergoing surgical procedure for rhegmatogenous retinal detachment were included in this study. Mean age was 62.2 years with 60% male subjects and 56% right eyes. Mean postoperative follow-up was 9.6 months (range, 6 weeks to 10 years). With univariate analysis, the presence of superotemporal breaks was associated with a reduction in the chance of failed primary surgery (P = 0.005); detached inferonasal breaks (P = 0.002), proliferative vitreoretinopathy (PVR) (P detached inferior retina (P detachment (P detached inferior breaks, increased number of breaks, and 4-quadrant detachment remained associated with an increased risk of failure, and superotemporal detached breaks with the reduced risk of failure (r(2) = 0.08). For patients without PVR, only inferonasal detached breaks and 3 to 4 quadrants of detachment remained predictive of failure (r(2) = 0.04). For patients with PVR (n = 120), multivariate analysis showed that PVR C4-12 and posterior breaks increased the failure risk and detached superotemporal breaks reduced the risk of failure (r(2) = 0.22). Number of breaks, inferior positioning of breaks, the extent of rhegmatogenous retinal detachment, and PVR are associated with failed primary surgery.

  6. Self-assembled nanocages based on the coiled coil bundle motif

    Science.gov (United States)

    Sinha, Nairiti; Villegas, Jose; Saven, Jeffery; Kiick, Kristi; Pochan, Darrin

    Computational design of coiled coil peptide bundles that undergo solution phase self-assembly presents a diverse toolbox for engineering new materials with tunable and pre-determined nanostructures that can have various end applications such as in drug delivery, biomineralization and electronics. Self-assembled cages are especially advantageous as the cage geometry provides three distinct functional sites: the interior, the exterior and the solvent-cage interface. In this poster, syntheses and characterization of a peptide cage based on computationally designed homotetrameric coiled coil bundles as building blocks is discussed. Techniques such as Transmission Electron Microscopy (TEM), Small-Angle Neutron Scattering (SANS) and Analytical Ultracentrifugation (AUC) are employed to characterize the size, shape and molecular weight of the self-assembled peptide cages under different pH and temperature conditions. Various self-assembly pathways such as dialysis and thermal quenching are shown to have a significant impact on the final structure of these peptides in solution. Comparison of results with the target cage design can be used to iteratively improve the peptide design and provide greater understanding of its interactions and folding.

  7. Accommodating Discontinuities in Dimeric Left-Handed Coiled Coils in ATP Synthase External Stalks

    Science.gov (United States)

    Wise, John G.; Vogel, Pia D.

    2009-01-01

    ATP synthases from coupling membranes are complex rotary motors that convert the energy of proton gradients across coupling membranes into the chemical potential of the β-γ anhydride bond of ATP. Proton movement within the ring of c subunits localized in the F0-sector drives γ and ɛ rotation within the F1α3β3 catalytic core where substrates are bound and products are released. An external stalk composed of homodimeric subunits b2 in Escherichia coli or heterodimeric bb′ in photosynthetic synthases connects F0 subunit a with F1 subunits δ and most likely α. The external stalk resists rotation, and is of interest both functionally and structurally. Hypotheses that the external stalk contributes to the overall efficiency of the reaction through elastic coupling of rotational substeps, and that stalks form staggered, right-handed coiled coils, are investigated here. We report on different structures that accommodate heptad discontinuities with either local or global underwinding. Analyses of the knob-and-hole packing of the E. coli b2 and Synechocystis bb′ stalks strongly support the possibility that these proteins can adopt conventional left-handed coiled coils. PMID:19348765

  8. Structure and Misfolding of the Flexible Tripartite Coiled-Coil Domain of Glaucoma-Associated Myocilin

    Energy Technology Data Exchange (ETDEWEB)

    Hill, Shannon E.; Nguyen, Elaine; Donegan, Rebecca K.; Patterson-Orazem, Athéna C.; Hazel, Anthony; Gumbart, James C.; Lieberman, Raquel L.

    2017-11-01

    Glaucoma-associated myocilin is a member of the olfactomedins, a protein family involved in neuronal development and human diseases. Molecular studies of the myocilin N-terminal coiled coil demonstrate a unique tripartite architecture: a Y-shaped parallel dimer-of-dimers with distinct tetramer and dimer regions. The structure of the dimeric C-terminal 7-heptad repeats elucidates an unexpected repeat pattern involving inter-strand stabilization by oppositely charged residues. Molecular dynamics simulations reveal an alternate accessible conformation in which the terminal inter-strand disulfide limits the extent of unfolding and results in a kinked configuration. By inference, full-length myocilin is also branched, with two pairs of C-terminal olfactomedin domains. Selected variants within the N-terminal region alter the apparent quaternary structure of myocilin but do so without compromising stability or causing aggregation. In addition to increasing our structural knowledge of naturally occurring extracellular coiled coils and biomedically important olfactomedins, this work broadens the scope of protein misfolding in the pathogenesis of myocilin-associated glaucoma.

  9. Magnetic field alignment of coil-coil diblock copolymers and blends via intrinsic chain anisotropy

    Science.gov (United States)

    Rokhlenko, Yekaterina; Majewski, Pawel; Larson, Steven; Yager, Kevin; Gopalan, Padma; Avgeropoulos, Apostolos; Chan, Edwin; Osuji, Chinedum

    Magnetic fields can control alignment of self-assembled soft materials such as block copolymers provided there is a suitably large magnetic susceptibility anisotropy present in the system. Recent results have highlighted the existence of a non-trivial intrinsic anisotropy in coil-coil diblock copolymers, specifically in lamellar-forming PS-b-P4VP, which enables alignment at field strengths of a few tesla in systems lacking mesogenic components. Alignment is predicated on correlation in the orientation of end-end vectors implied by the localization of block junctions at the microdomain interface and is observed on cooling across the order-disorder transition in the presence of the field. For appropriate combinations of field strength and grain size, we can leverage intrinsic chain anisotropy to magnetically direct self-assembly of many non-mesogenic systems, including other coil-coil BCPs like PS-b-PDMS and PS-b-PMMA, blends of BCPs of disparate morphologies and MWs, and blends of BCPs with homopolymers. This is noteworthy as blends of PS-b-P4VP with PEO provide a route to form functional materials such as nanoporous films by dissolution of PEO, or aligned ion conduction materials. We survey these various systems using TEM and in-situ X-ray scattering to study the phase behavior and temperature-, time- and field- dependent dynamics of alignment.

  10. Structure and Misfolding of the Flexible Tripartite Coiled-Coil Domain of Glaucoma-Associated Myocilin.

    Science.gov (United States)

    Hill, Shannon E; Nguyen, Elaine; Donegan, Rebecca K; Patterson-Orazem, Athéna C; Hazel, Anthony; Gumbart, James C; Lieberman, Raquel L

    2017-11-07

    Glaucoma-associated myocilin is a member of the olfactomedins, a protein family involved in neuronal development and human diseases. Molecular studies of the myocilin N-terminal coiled coil demonstrate a unique tripartite architecture: a Y-shaped parallel dimer-of-dimers with distinct tetramer and dimer regions. The structure of the dimeric C-terminal 7-heptad repeats elucidates an unexpected repeat pattern involving inter-strand stabilization by oppositely charged residues. Molecular dynamics simulations reveal an alternate accessible conformation in which the terminal inter-strand disulfide limits the extent of unfolding and results in a kinked configuration. By inference, full-length myocilin is also branched, with two pairs of C-terminal olfactomedin domains. Selected variants within the N-terminal region alter the apparent quaternary structure of myocilin but do so without compromising stability or causing aggregation. In addition to increasing our structural knowledge of naturally occurring extracellular coiled coils and biomedically important olfactomedins, this work broadens the scope of protein misfolding in the pathogenesis of myocilin-associated glaucoma. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Finite element modeling of TFTR poloidal field coils

    International Nuclear Information System (INIS)

    Baumgartner, J.A.; O'Toole, J.A.

    1986-01-01

    The Tokamak Fusion Test Reactor (TFTR) Poloidal Field (PF) coils were originally analyzed to TFTR design conditions. The coils have been reanalyzed by PPPL and Grumman to determine operating limits under as-built conditions. Critical stress levels, based upon data obtained from the reanalysis of each PF coil, are needed for input to the TFTR simulation code algorithms. The primary objective regarding structural integrity has been to ascertain the magnitude and location of critical internal stresses in each PF coil due to various combinations of electromagnetic and thermally induced loads. For each PF coil, a global finite element model (FEM) of a coil sector is being analyzed to obtain the basic coil internal loads and displacements. Subsequent fine mesh local models of the coil lead stem and lead spur regions produce the magnitudes and locations of peak stresses. Each copper turn and its surrounding insulation are modeled using solid finite elements. The corresponding electromagnetic and thermal analyses are similarly modeled. A series of test beams were developed to determine the best combination of MSC/NASTRAN-type finite elements for use in PF coil analysis. The results of this analysis compare favorably with those obtained by the earlier analysis which was limited in scope

  12. Switching transients in the MFTF yin-yang coils

    International Nuclear Information System (INIS)

    Owen, E.W.; Shimer, D.W.

    1982-01-01

    This report is a study of the transients caused by the fast dump of large superconducting coils. Theoretical analysis, computer simulation, and actual measurements are used. Theoretical analysis can only be applied to the simplest of models. In the computer simulations two models are used, one in which the coil is divided into ten segments and another in which a single coil is employed. The circuit breaker that interrupts the current to the power supply, causing a fast dump, is represented by a time and current dependent conductance. Actual measurements are limited to measurements made incidental to the coils' performance tests

  13. 7T head volume coils: improvements for rostral brain imaging.

    Science.gov (United States)

    Avdievich, Nikolai I; Hetherington, Hoby P; Kuznetsov, Andrey M; Pan, Jullie W

    2009-02-01

    To improve the performance of 7T head coils over the rostral head regions. Due to radiofrequency (RF) field/tissue interactions, the RF magnetic field profile produced by 7T volume head coils is very inhomogeneous, with enhanced sensitivity near the center of the human brain and substantially reduced in the periphery. Two head-sized quadrature volume coils of similar diameters but substantially different lengths (17 and 10 cm) were constructed and tested using a 7T Varian Inova system. Experimental data demonstrated that by using a shorter volume head-sized coil or simply by partially moving a head out of the coil, coil efficiency near the top of a head can be improved by 20%. The homogeneity also improved, largely resulting from an increase in peripheral B(1) values. This resulted in 10%-20% variation in axial slices located near the top of a head. We have demonstrated a less deeply positioned head or substantially shorter volume coil can significantly improve coil performance and homogeneity for the rostral head at ultrahigh magnetic fields (7T and above). For studies that target superior brain regions, this coil arrangement can be highly effective.

  14. Relationship between voice coil fill factor and loudspeaker efficiency

    DEFF Research Database (Denmark)

    Iversen, Niels Elkjær; Knott, Arnold; Andersen, Michael A. E.

    2016-01-01

    -mode technology, can be designed to much lower loads. A thorough analysis of the loudspeaker efficiency is presented and its relation to the voice coil fill factor is described. In addition to this the influence of the driver’s mass ratio is investigated and it is found that high mass ratios is beneficial...... for the efficiency of drivers using high fill factor voice coils. Different voice coil winding strategies are described and their fill factors analysed. It is found that by lowering the nominal resistance of a voice coil, using rectangular wire, one can increase the fill factor. However a practical realization...

  15. Symmetry-Directed Self-Assembly of a Tetrahedral Protein Cage Mediated by de Novo-Designed Coiled Coils.

    Science.gov (United States)

    Badieyan, Somayesadat; Sciore, Aaron; Eschweiler, Joseph D; Koldewey, Philipp; Cristie-David, Ajitha S; Ruotolo, Brandon T; Bardwell, James C A; Su, Min; Marsh, E Neil G

    2017-10-05

    The organization of proteins into new hierarchical forms is an important challenge in synthetic biology. However, engineering new interactions between protein subunits is technically challenging and typically requires extensive redesign of protein-protein interfaces. We have developed a conceptually simple approach, based on symmetry principles, that uses short coiled-coil domains to assemble proteins into higher-order structures. Here, we demonstrate the assembly of a trimeric enzyme into a well-defined tetrahedral cage. This was achieved by genetically fusing a trimeric coiled-coil domain to its C terminus through a flexible polyglycine linker sequence. The linker length and coiled-coil strength were the only parameters that needed to be optimized to obtain a high yield of correctly assembled protein cages. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Crystal structure of tetranectin, a trimeric plasminogen-binding protein with an alpha-helical coiled coil

    DEFF Research Database (Denmark)

    Nielsen, B B; Kastrup, J S; Rasmussen, H

    1997-01-01

    Tetranectin is a plasminogen kringle 4-binding protein. The crystal structure has been determined at 2.8 A resolution using molecular replacement. Human tetranectin is a homotrimer forming a triple alpha-helical coiled coil. Each monomer consists of a carbohydrate recognition domain (CRD) connected...... the third is present only in long-form CRDs. Tetranectin represents the first structure of a long-form CRD with intact calcium-binding sites. In tetranectin, the third disulfide bridge tethers the CRD to the long helix in the coiled coil. The trimerization of tetranectin as well as the fixation of the CRDs...... relative to the helices in the coiled coil indicate a demand for high specificity in the recognition and binding of ligands....

  17. Umbilical cord coiling index and perinatal outcome.

    Science.gov (United States)

    Patil, Nivedita S; Kulkarni, Sunanda R; Lohitashwa, Renu

    2013-08-01

    To evaluate the perinatal outcome with the abnormal umbilical cord coiling index. This prospective study was carried out in the department of OBG at Adichunchangiri Institute of Medical Sciences, B.G.Nagara, Mandya, Karnataka, India from January 2008 to August 2010. 200 patients who were in active labour with term gestations, irrespective of their parities, who had singleton pregnancies with live babies who were either delivered by vaginal or LSCS were included in the study. Umbilical cord coiling index was calculated and it was correlated with various perinatal parameters like birth weight, meconium stained liquor, Apgar score, ponderal index and foetal growth restriction. Chi square and Fisher exact tests were used to find the significance of study parameters. There was a significant correlation between the hypercoiled cords (UCI >90(th) percentile) and IUGR of the babies (p value of UCI which was UCI which was > 90(th) percentile was associated with IUGR and low ponderal indices. Hypocoiled cords or UCI which was <10th percentile was associated with meconium staining, Apgar score at 1 min of <4 and at 5 min of <7, more LSCS rates and more NICU admissions.

  18. Abrupt tectonics and rapid slab detachment with grain damage.

    Science.gov (United States)

    Bercovici, David; Schubert, Gerald; Ricard, Yanick

    2015-02-03

    A simple model for necking and detachment of subducting slabs is developed to include the coupling between grain-sensitive rheology and grain-size evolution with damage. Necking is triggered by thickened buoyant crust entrained into a subduction zone, in which case grain damage accelerates necking and allows for relatively rapid slab detachment, i.e., within 1 My, depending on the size of the crustal plug. Thick continental crustal plugs can cause rapid necking while smaller plugs characteristic of ocean plateaux cause slower necking; oceanic lithosphere with normal or slightly thickened crust subducts without necking. The model potentially explains how large plateaux or continental crust drawn into subduction zones can cause slab loss and rapid changes in plate motion and/or induce abrupt continental rebound.

  19. Evaluation of metal trace detachment from dosing pumps using PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Lozano, Omar, E-mail: omar.lozanogarcia@unamur.be [Research Centre for the Physics of Matter and Radiation (PMR), Namur Nanosafety Centre (NNC), Namur Research Institute for Life Sciences - NARILIS, University of Namur - UNamur, Rue de Bruxelles 61, B-5000 Namur (Belgium); Mejia, Jorge [Research Centre for the Physics of Matter and Radiation (PMR), Namur Nanosafety Centre (NNC), Namur Research Institute for Life Sciences - NARILIS, University of Namur - UNamur, Rue de Bruxelles 61, B-5000 Namur (Belgium); Laloy, Julie; Alpan, Lütfiye [Namur Thrombosis and Hemostasis Centre (NTHC), Namur Nanosafety Centre (NNC), Namur Research Institute for Life Sciences - NARILIS, University of Namur - UNamur, Rue de Bruxelles 61, B-5000 Namur (Belgium); Toussaint, Olivier [Laboratory of Biochemistry and Cellular Biology (URBC), Namur Nanosafety Centre (NNC), Namur Research Institute for Life Sciences - NARILIS, University of Namur - UNamur, Rue de Bruxelles 61, B-5000 Namur (Belgium); Dogné, Jean-Michel [Namur Thrombosis and Hemostasis Centre (NTHC), Namur Nanosafety Centre (NNC), Namur Research Institute for Life Sciences - NARILIS, University of Namur - UNamur, Rue de Bruxelles 61, B-5000 Namur (Belgium); Lucas, Stéphane [Research Centre for the Physics of Matter and Radiation (PMR), Namur Nanosafety Centre (NNC), Namur Research Institute for Life Sciences - NARILIS, University of Namur - UNamur, Rue de Bruxelles 61, B-5000 Namur (Belgium)

    2014-07-15

    Metal trace detachment evaluation is essential for instruments destined for pharmaceutical applications, such as pumps. Particle-Induced X-ray Emission (PIXE) was used to determine and quantify metal traces originated from stainless steel and ceramic dosing pumps. Metal traces were quantified from either distilled water samples or cellulose filters in two tests: a short-term test of 16 h mimicking a daily cycle of a dosing pump for industrial applications, and a long-term test of 9 days evaluating the pump wearing. The main result is that ceramic dosing pumps present lower metal detachment than stainless steel counterparts. Traces of Si and Al were found originating from pieces around the pumps (pipes and joints)

  20. Intellectual property rights and detached human body parts.

    Science.gov (United States)

    Pila, Justine

    2014-01-01

    This paper responds to an invitation by the editors to consider whether the intellectual property (IP) regime suggests an appropriate model for protecting interests in detached human body parts. It begins by outlining the extent of existing IP protection for body parts in Europe, and the relevant strengths and weaknesses of the patent system in that regard. It then considers two further species of IP right of less obvious relevance. The first are the statutory rights of ownership conferred by domestic UK law in respect of employee inventions, and the second are the economic and moral rights recognised by European and international law in respect of authorial works. In the argument made, both of these species of IP right may suggest more appropriate models of sui generis protection for detached human body parts than patent rights because of their capacity better to accommodate the relevant public and private interests in respect of the same.