WorldWideScience

Sample records for gt-2 fenton hill

  1. Water quality in vicinity of Fenton Hill Site, 1974

    International Nuclear Information System (INIS)

    Purtymun, W.D.; Adams, W.H.; Owens, J.W.

    1975-09-01

    The water quality at nine surface water stations, eight ground water stations, and the drilling operations at the Fenton Hill Site have been studied as a measure of the environmental impact of the Los Alamos Scientific Laboratory geothermal experimental studies in the Jemez Mountains. Surface water quality in the Jemez River drainage area is affected by the quality of the inflow from thermal and mineral springs. Ground water discharges from the Cenozoic Volcanics are similar in chemical quality. Water in the main zone of saturation penetrated by test hole GT-2 is highly mineralized, whereas water in the lower section of the hole, which is in granite, contains a higher concentration of uranium

  2. A Brief History With Lessons Learned From The Hot Dry Rock Geothermal Energy Program At Fenton Hill, New Mexico, USA

    Science.gov (United States)

    Kelkar, S.; Woldegabriel, G. W.; Rehfeldt, K. R.

    2009-12-01

    and tracer data led to the conclusion that having multiple production wells could lead to improved energy extraction. Geochemical techniques were refined and tests were designed to use reactive tracers that could provide estimates of the reservoir temperature profiles. Water-rock interactions were found to be modest and did not significantly impact the surface plant operations. Numerous small seismic events were generated during hydraulic stimulations but they were of a very small magnitude and none caused noticeable movement at the land surface. The effects of reservoir stimulation were found to persist over a period of nearly 2 years after shut in. Cyclic flow tests demonstrated the ability of the HDR reservoir at Fenton Hill to regulate peak load demands, and the ability to act as an energy storage system. These tests demonstrated actual increase in the thermal output of the reservoir during cyclic production tests.HDR Reservoir Characteristics at Fenton Hill

  3. Environmental studies conducted at the Fenton Hill Hot Dry Rock geothermal development site

    Energy Technology Data Exchange (ETDEWEB)

    Miera, F.R. Jr.; Langhorst, G.; McEllin, S.; Montoya, C.

    1984-05-01

    An environmental investigation of Hot Dry Rock (HDR) geothermal development was conducted at Fenton Hill, New Mexico, during 1976-1979. Activities at the Fenton Hill Site included an evaluation of baseline data for biotic and abiotic ecosystem components. Identification of contaminants produced by HDR processes that had the potential for reaching the surrounding environment is also discussed. Three dominant vegetative communities were identified in the vicinity of the site. These included grass-forb, aspen, and mixed conifer communities. The grass-forb area was identified as having the highest number of species encountered, with Phleum pratense and Dactylis glomerata being the dominant grass species. Frequency of occurrence and mean coverage values are also given for other species in the three main vegetative complexes. Live trapping of small mammals was conducted to determine species composition, densities, population, and diversity estimates for this component of the ecosystem. The data indicate that Peromyscus maniculatus was the dominant species across all trapping sites during the study. Comparisons of relative density of small mammals among the various trapping sites show the grass-forb vegetative community to have had the highest overall density. Comparisons of small mammal diversity for the three main vegetative complexes indicate that the aspen habitat had the highest diversity and the grass-forb habitat had the lowest. Analyses of waste waters from the closed circulation loop indicate that several trace contaminants (e.g., arsenic, cadmium, fluoride, boron, and lithium) were present at concentrations greater than those reported for surface waters of the region.

  4. Drilling fluids and lost circulation in hot-dry-rock geothermal wells at Fenton Hill

    Energy Technology Data Exchange (ETDEWEB)

    Nuckols, E.B.; Miles, D.; Laney, R.; Polk, G.; Friddle, H.; Simpson, G.

    1981-01-01

    Geothermal hot dry rock drilling at Fenton Hill in northern New Mexico encountered problems of catastrophic lost circulation in cavernous areas of limestones in the Sandia Formation, severe corrosion due to temperatures of up to 320/sup 0/C, and torque problems caused by 35/sup 0/ hole angle and the abrasiveness of Precambrian crystalline rock. The use of polymeric flocculated bentonite fluid, clear water, fibrous material, dry drilling, oxygen scavengers, a biodegradable lubricant mixture of modified triglicerides and alcohol, and maintenance of a high pH, were some of the approaches taken toward solving these problems.

  5. Numerical Modeling of Permeability Enhancement by Hydroshearing: the Case of Phase I Reservoir Creation at Fenton Hill

    Science.gov (United States)

    Rutqvist, J.; Rinaldi, A. P.

    2017-12-01

    The exploitation of a geothermal system is one of the most promising clean and almost inexhaustible forms of energy production. However, the exploitation of hot dry rock (HDR) reservoirs at depth requires circulation of a large amount of fluids. Indeed, the conceptual model of an Enhanced Geothermal System (EGS) requires that the circulation is enhanced by fluid injection. The pioneering experiments at Fenton Hill demonstrated the feasibility of EGS by producing the world's first HDR reservoirs. Such pioneering project demonstrated that the fluid circulation can be effectively enhanced by stimulating a preexisting fracture zone. The so-called "hydroshearing" involving shear activation of preexisting fractures is recognized as one of the main processes effectively enhancing permeability. The goal of this work is to quantify the effect of shear reactivation on permeability by proposing a model that accounts for fracture opening and shearing. We develop a case base on a pressure stimulation experiment at Fenton Hill, in which observation suggest that a fracture was jacked open by pressure increase. The proposed model can successfully reproduce such a behavior, and we compare the base case of pure elastic opening with the hydroshearing model to demonstrate that this latter could have occurred at the field, although no "felt" seismicity was observed. Then we investigate on the sensitivity of the proposed model by varying some of the critical parameters such as the maximum aperture, the dilation angle, as well as the fracture density.

  6. Cosmetic wastewater treatment using the Fenton, Photo-Fenton and H2O2/UV processes.

    Science.gov (United States)

    Marcinowski, Piotr P; Bogacki, Jan P; Naumczyk, Jeremi H

    2014-01-01

    Advanced Oxidation Processes (AOPs), such as the Fenton, photo-Fenton and H2O2/UV processes, have been investigated for the treatment of cosmetic wastewaters that were previously coagulated by FeCl3. The Photo-Fenton process at pH 3.0 with 1000/100 mg L(-1) H2O2/Fe(2+) was the most effective (74.0% Chemical Oxygen Demand (COD) removal). The Fenton process with 1200/500 mg L(-1) H2O2/Fe(2+) achieved a COD removal of 72.0%, and the H2O2/UV process achieved a COD removal of 47.0%. Spreading the H2O2 doses over time to obtain optimal conditions did not improve COD removal. The kinetics of the Fenton and photo-Fenton processes may be described by the following equation: d[COD]/dt = -a[COD] t(m) (t represents time and a and m are constants). The rate of COD removal by the H2O2/UV process may be described by a second-order reaction equation. Head Space, Solid-Phase MicroExtraction, Gas Chromatography and Mass Spectrometry (HS-SPME-GC-MS) were used to identify 48 substances in precoagulated wastewater. Among these substances, 26 were fragrances. Under optimal AOP conditions, over 99% of the identified substances were removed in 120 min.

  7. Removal of citrate and hypophosphite binary components using Fenton, photo-Fenton and electro-Fenton processes

    Institute of Scientific and Technical Information of China (English)

    Yao-Hui Huang; Hsiao-Ting Su; Li-Way Lin

    2009-01-01

    Both citrate and hypophosphite in aqueous solution were degraded by advanced oxidation processes (Fe2+/H2O2, UV/Fe2+/H2O2, and electrolysis/ Fe2+/H2O2) in this study. Comparison of these techniques in oxidation efficiency was undertaken. It was found that Fenton process could not degrade completely citrate in the presence of hypophosphite since it caused a series inhibition. Therefore, UV light (photo-Fenton) or electron current (electro-Fenton) was applied to improve the degradation efficiency of the Fenton process. Results showed that both photo-Fenton and electro-Fenton processes could overcome the inhibition of hypophosphite, especially the electro-Fenton.

  8. Municipal solid waste landfill leachate treatment by fenton, photo-fenton and fenton-like processes: Effect of some variables

    Science.gov (United States)

    2012-01-01

    Advanced oxidation processes like Fenton and photo-Fenton have been effectively applied to oxidize the persistent organic compounds in solid waste leachate and convert them to unharmful materials and products. However, there are limited data about application of Fenton-like process in leachate treatment. Therefore, this study was designed with the objective of treating municipal landfill leachate by Fenton, Fenton-like and photo–Fenton processes to determine the effect of different variables, by setting up a pilot system. The used leachate was collected from a municipal unsanitary landfill in Qaem-Shahr in the north of Iran. Fenton and Fenton-like processes were conducted by Jar-test method. Photo-Fenton process was performed in a glass photo-reactor. In all processes, H2O2 was used as the oxidant. FeSO4.7H2O and FeCl3.6H2O were used as reagents. All parameters were measured based on standard methods. The results showed that the optimum concentration of H2O2 was equal to 5 g/L for the Fenton-like process and 3 g/L for the Fenton and photo-Fenton processes. The optimum ratio of H2O2: Fe+2/Fe+3 were equal to 8:1 in all processes. At optimum conditions, the amount of COD removal was 69.6%, 65.9% and 83.2% in Fenton, Fenton-like and photo–Fenton processes, respectively. In addition, optimum pH were 3, 5 and 3 and the optimum contact time were 150, 90 and 120 minutes, for Fenton, Fenton-like and photo–Fenton processes, respectively. After all processes, the biodegradability (BOD5/COD ratio) of the treated leachate was increased compared to that of the raw leachate and the highest increase in BOD5/COD ratio was observed in the photo-Fenton process. The efficiency of the Fenton-like process was overally less than Fenton and photo-Fenton processes, meanwhile the Fenton-like process was at higher pH and did not show problems. PMID:23369204

  9. Mineralization of herbicide 3,6-dichloro-2-methoxybenzoic acid in aqueous medium by anodic oxidation, electro-Fenton and photoelectro-Fenton

    International Nuclear Information System (INIS)

    Brillas, Enric; Banos, Miguel Angel; Garrido, Jose Antonio

    2003-01-01

    The mineralization of acidic aqueous solutions with 230 and 115 ppm of herbicide 3,6-dichloro-2-methoxybenzoic acid (dicamba) in 0.05 M Na 2 SO 4 of pH 3.0 has been studied by electro-Fenton and photoelectro-Fenton using a Pt anode and an O 2 -diffusion cathode, where oxidizing hydroxyl radicals are produced from Fenton's reaction between added Fe 2+ and H 2 O 2 generated by the cathode. While electro-Fenton only yields 60-70% mineralization, photoelectro-Fenton allows a fast and complete depollution of herbicide solutions, even at low currents, by the action of UV irradiation. In both treatments, the initial chlorine is rapidly released to the medium as chloride ion. Comparative electrolyses by anodic oxidation in the absence and presence of electrogenerated H 2 O 2 give very poor degradation. The dicamba decay follows a pseudo-first-order reaction, as determined by reverse-phase chromatography. Formic, maleic and oxalic acids have been detected in the electrolyzed solutions by ion-exclusion chromatography. In electro-Fenton, all formic acid is transformed into CO 2 , and maleic acid is completely converted into oxalic acid, remaining stable Fe 3+ -oxalato complexes in the solution. The fast mineralization of such complexes by UV light explains the highest oxidative ability of photoelectro-Fenton

  10. Decolorization of C.I. Acid Blue 9 solution by UV/Nano-TiO2, Fenton, Fenton-like, electro-Fenton and electrocoagulation processes: A comparative study

    International Nuclear Information System (INIS)

    Khataee, A.R.; Vatanpour, V.; Amani Ghadim, A.R.

    2009-01-01

    This study makes a comparison between UV/Nano-TiO 2 , Fenton, Fenton-like, electro-Fenton (EF) and electrocoagulation (EC) treatment methods to investigate the removal of C.I. Acid Blue 9 (AB9), which was chosen as the model organic contaminant. Results indicated that the decolorization efficiency was in order of Fenton > EC > UV/Nano-TiO 2 > Fenton-like > EF. Desired concentrations of Fe 2+ and H 2 O 2 for the abatement of AB9 in the Fenton-based processes were found to be 10 -4 M and 2 x 10 -3 M, respectively. In the case of UV/Nano-TiO 2 process, we have studied the influence of the basic photocatalytic parameters such as the irradiation time, pH of the solution and amount of TiO 2 nanoparticles on the photocatalytic decolorization efficiency of AB9. Accordingly, it could be stated that the complete removal of color, after selecting desired operational parameters could be achieved in a relatively short time, about 25 min. Our results also revealed that the most effective decomposition of AB9 was observed with 150 mg/l of TiO 2 nanoparticles in acidic condition. The effect of operational parameters including current density, initial pH and time of electrolysis were studied in electrocoagulation process. The results indicated that for a solution of 20 mg/l AB9, almost 98% color were removed, when the pH was about 6, the time of electrolysis was 8 min and the current density was approximately 25 A/m 2 in electrocoagulation process

  11. Alkydic resin wastewaters treatment by fenton and photo-Fenton processes

    International Nuclear Information System (INIS)

    Schwingel de Oliveira, Isadora; Viana, Lilian; Verona, Cenira; Fallavena, Vera Lucia Vargas; Azevedo, Carla Maria Nunes; Pires, Marcal

    2007-01-01

    Advanced oxidation processes are an emerging option to treatment of the painting industry effluents. The aim of this study was to compare the effectiveness of the Fenton and photo-Fenton processes in chemical oxygen demand (COD), total organic carbon (TOC) and phenolic compounds removal from wastewaters generated during alkydic resins manufacture. The optimized treatment conditions are the following: pH 3.0, 15.15 x 10 -3 mol L -1 FeSO 4 and 0.30 mol L -1 H 2 O 2 for a reaction time of 6 h. photo-Fenton experiments were carried out in the presence of sunlight or artificial radiation and complementary additions of H 2 O 2 were made for all experiments. The best results were obtained with photo-Fenton process assisted with solar radiation, with reductions of 99.5 and 99.1% of COD and TOC levels, respectively. Fenton and photo-Fenton (with artificial irradiation) processes presented lower but not insignificant removals, within 60-80% reduction for both COD and TOC. In addition, an excellent removal (95%) of total phenols was obtained using photo-Fenton process assisted with artificial irradiation. This study demonstrated that the use of photo-Fenton process on alkydic resins wastewater treatment is very promising especially when solar light is used

  12. Decolorization of C.I. Acid Blue 9 solution by UV/Nano-TiO{sub 2}, Fenton, Fenton-like, electro-Fenton and electrocoagulation processes: A comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Khataee, A.R. [Water and Wastewater Treatment Research Laboratory, Department of Applied Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz (Iran, Islamic Republic of)], E-mail: a_khataee@tabrizu.ac.ir; Vatanpour, V. [Water and Wastewater Treatment Research Laboratory, Department of Applied Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz (Iran, Islamic Republic of)], E-mail: vahidvatanpoor@yahoo.com; Amani Ghadim, A.R. [Water and Wastewater Treatment Research Laboratory, Department of Applied Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz (Iran, Islamic Republic of)], E-mail: a.r_amani@yahoo.com

    2009-01-30

    This study makes a comparison between UV/Nano-TiO{sub 2}, Fenton, Fenton-like, electro-Fenton (EF) and electrocoagulation (EC) treatment methods to investigate the removal of C.I. Acid Blue 9 (AB9), which was chosen as the model organic contaminant. Results indicated that the decolorization efficiency was in order of Fenton > EC > UV/Nano-TiO{sub 2} > Fenton-like > EF. Desired concentrations of Fe{sup 2+} and H{sub 2}O{sub 2} for the abatement of AB9 in the Fenton-based processes were found to be 10{sup -4} M and 2 x 10{sup -3} M, respectively. In the case of UV/Nano-TiO{sub 2} process, we have studied the influence of the basic photocatalytic parameters such as the irradiation time, pH of the solution and amount of TiO{sub 2} nanoparticles on the photocatalytic decolorization efficiency of AB9. Accordingly, it could be stated that the complete removal of color, after selecting desired operational parameters could be achieved in a relatively short time, about 25 min. Our results also revealed that the most effective decomposition of AB9 was observed with 150 mg/l of TiO{sub 2} nanoparticles in acidic condition. The effect of operational parameters including current density, initial pH and time of electrolysis were studied in electrocoagulation process. The results indicated that for a solution of 20 mg/l AB9, almost 98% color were removed, when the pH was about 6, the time of electrolysis was 8 min and the current density was approximately 25 A/m{sup 2} in electrocoagulation process.

  13. Decolorization of Industrial Waste Using Fenton Process and Photo Fenton

    OpenAIRE

    Wardiyati, Siti; Dewi, Sari Hasnah; Fisli, Adel

    2013-01-01

    Industrial waste water decolorization has been done using the method of Fenton and Photo Fenton. The experiment was conducted in order to obtain the optimum process conditions for industrial waste treatment method with Fenton and Photo Fenton. Industrial waste used in this experiment waste of blue batik making process derived from Rara Djograng Batik Yogyakarta. Factors were studied in this research are the effect of the amount of catalyst FeSO4.7H2O, the amount of oxidant H2O2, and the time ...

  14. Fast decolorization of azo methyl orange via heterogeneous Fenton and Fenton-like reactions using alginate-Fe2+/Fe3+ films as catalysts.

    Science.gov (United States)

    Quadrado, Rafael F N; Fajardo, André R

    2017-12-01

    The efficiency of Fenton and Fenton-like processes can be seriously affected by the continuous loss of iron ions and by the formation of solid sludge. Here, alginate (Alg) films were synthesized to stabilize iron ions (Fe 2+ and Fe 3+ ) and to enhance their catalytic activities towards the decolorization of methyl orange via heterogeneous Fenton and Fenton-like processes. Iron ions were ionically bond to the Alg molecules resulting in a three-dimensional network with specific structural and morphological features according to the valence states of iron. Our results demonstrated that both Alg-Fe 2+ and Alg-Fe 3+ films show highlighted catalytic activity for the decolorization of MO and high decolorization rates. Reuse experiments demonstrated that both films could be employed in at least five consecutive decolorization processes without losing their catalytic efficiency or stability. Taken together, our findings reveal that the Alg-Fe 2+ and Alg-Fe 3+ films may be suitable low-cost catalysts in heterogeneous Fenton and Fenton-like processes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Enhanced degradation of paracetamol by UV-C supported photo-Fenton process over Fenton oxidation.

    Science.gov (United States)

    Manu, B; Mahamood, S

    2011-01-01

    For the treatment of paracetamol in water, the UV-C Fenton oxidation process and classic Fenton oxidation have been found to be the most effective. Paracetamol reduction and chemical oxygen demand (COD) removal are measured as the objective functions to be maximized. The experimental conditions of the degradation of paracetamol are optimized by the Fenton process. Influent pH 3, initial H(2)O(2) dosage 60 mg/L, [H(2)O(2)]/[Fe(2+)] ratio 60 : 1 are the optimum conditions observed for 20 mg/L initial paracetamol concentration. At the optimum conditions, for 20 mg/L of initial paracetamol concentration, 82% paracetamol reduction and 68% COD removal by Fenton oxidation, and 91% paracetamol reduction and 82% COD removal by UV-C Fenton process are observed in a 120 min reaction time. By HPLC analysis, 100% removal of paracetamol is observed at the above optimum conditions for the Fenton process in 240 min and for the UV-C photo-Fenton process in 120 min. The methods are effective and they may be used in the paracetamol industry.

  16. Evaluation of Efficacy of Advanced Oxidation Processes Fenton, Fenton-like and Photo-Fenton for Removal of Phenol from Aqueous Solutions

    International Nuclear Information System (INIS)

    Mofrad, M. R.; Akbari, H.; Miranzadeh, M. B.; Nezhad, M. E.; Atharizade, M.

    2015-01-01

    Contamination of water, soil and groundwater caused by aromatic compounds induces great concern in most world areas. Among organic pollutants, phenol is mostly considered dangerous due to its high toxicity for human and animal. Advanced oxidation processes (AOPs) is considered as a most efficient method also the best one for purifying organic compounds which are resistant to conventional physical and chemical processes. This experimental study was carried out in laboratory scale. First, a synthetic solution was made of phenol. Then, Fenton, Fenton-like and photo-Fenton processes were applied removing phenol from aquatic solution. The effects of Hydrogen Peroxide concentration, catalyst, pH and time were studied to phenol removal efficiency. Results showed that Photo-Fenton process with removal efficiency (97.5 percentage) is more efficient than Fenton and Fenton-like processes with removal efficiency (78.7 percentage and 82.5 percentage respectively), in pH=3, (H/sub 2/O/sub 2/)= 3mM, (Fe2+)= 0.1 mM, phenol concentration 100 mg L-1 and time reaction 60 min, the phenol removal was 97.5 percentage. (author)

  17. Advanced oxidation of Reactive Blue 181 solution: a comparison between Fenton and Sono-Fenton process.

    Science.gov (United States)

    Basturk, Emine; Karatas, Mustafa

    2014-09-01

    In this work, the decolorization of C.I. Reactive Blue 181 (RB181), an anthraquinone dye, by Ultrasound and Fe(2+) H2O2 processes was investigated. The effects of operating parameters, such as Fe(2+) dosage, H2O2 dosage, pH value, reaction time and temperature were examined. Process optimisation [pH, ferrous ion (Fe(2+)), hydrogen peroxide (H2O2), and reaction time], kinetic studies and their comparison were carried out for both of the processes. The Sono-Fenton process was performed by indirect sonication in an ultrasonic water bath, which was operated at a fixed 35-kHz frequency. The optimum conditions were determined as [Fe(2+)]=30 mg/L, [H2O2]=50 mg/L and pH=3 for the Fenton process and [Fe(2+)]=10 mg/L, [H2O2]=40 mg/L and pH=3 for the Sono-Fenton process. The colour removals were 88% and 93.5% by the Fenton and Sono-Fenton processes, respectively. The highest decolorization was achieved by the Sono-Fenton process because of the production of some oxidising agents as a result of sonication. The paper also discussed kinetic parameters. The decolorization kinetic of RB181 followed pseudo-second-order reaction (Fenton study) and Behnajady kinetics (Sono-Fenton study). Copyright © 2014 Elsevier B.V. All rights reserved.

  18. The reactor design and comparison of Fenton, electro-Fenton and photoelectro-Fenton processes for mineralization of benzene sulfonic acid (BSA)

    International Nuclear Information System (INIS)

    Ting, W.-P.; Lu, M.-C.; Huang, Y.-H.

    2008-01-01

    A new approach for promoting ferric reduction efficiency using a different electrochemical cell and the photoelectro-Fenton process has been developed. The use of UVA light and electric current as electron donors can efficiently initiate the Fenton reaction. Benzene sulfonic acid (BSA) was the target compound in this study. The parameters investigated to evaluate the reactor design include the electrode working area, electrode distance, energy consumption. Furthermore, the study also contains the intermediates and the mineralization efficiency of electrolysis, Fenton, electro-Fenton and photoelectro-Fenton process. Oxalic acid, the major intermediate of aromatic compound degradation, can complex with ferric ions. Meanwhile, a double cathode reactor could increase the current efficiency by 7%, which would translate to greater ferrous production and a higher degradation rate. Although the current efficiency of an electrode distance 5.5 cm device is 19% higher than 3.0 cm, results show that after 2 h of electrolysis the electronic expense using an electrode gap of 5.5 cm is much higher than 3.0 cm. The final TOC removal efficiency was 46, 64 and 72% using the Fenton, electro-Fenton and photoelectron-Fenton processes, respectively

  19. SIMULTANEOUS DEGRADATION OF SOME PHTHALATE ESTERS UNDER FENTON AND PHOTO-FENTON OXIDATION PROCESSES

    Directory of Open Access Journals (Sweden)

    BELDEAN-GALEA M.S.

    2015-03-01

    Full Text Available In this study the assessment of the degradation efficiency of five phthalates, DEP, BBP, DEHP, DINP and DIDP, found in a mixture in a liquid phase, using the Fenton and Photo Fenton oxidation processes, was conducted. It was observed that the main parameters that influence the Fenton oxidative processes of phthalates were the concentration of the oxidizing agent, H2O2, the concentration of the catalyst used, Fe2+, the pH value, UV irradiation and the reaction time. For the Fenton oxidative process, the highest degradation efficiencies were 19% for DEP, 50% for BBP, 84% for DEHP, 90% for DINP and 48% for DIDP, when the experiments were carried out using concentrations of 20 mg L-1 phthalate mixture, 100 mg L-1 H2O2, 10 mg L-1 Fe2+ at a pH value of 3, with a total reaction time of 30 minutes. For the Photo-Fenton oxidative process carried out in the same conditions as Fenton oxidative process, it was observed that after an irradiation time of 90 minutes under UV radiation the degradation efficiencies of phthalates were improved, being 22% for DEP, 71% for BBP, 97% for DEHP, 97% for DINP and 81% for DIDP.

  20. Acetaminophen degradation by electro-Fenton and photoelectro-Fenton using a double cathode electrochemical cell

    International Nuclear Information System (INIS)

    Luna, Mark Daniel G. de; Veciana, Mersabel L.; Su, Chia-Chi; Lu, Ming-Chun

    2012-01-01

    Highlights: ► The electro-Fenton reactor using a double cathode electrochemical cell was applied. ► The initial Fe 2+ concentration was the most significant parameter for the acetaminophen degradation. ► Thirteen intermediates were identified and a degradation pathway was proposed. - Abstract: Acetaminophen is a widely used drug worldwide and is one of the most frequently detected in bodies of water making it a high priority trace pollutant. This study investigated the applicability of the electro-Fenton and photoelectro-Fenton processes using a double cathode electrochemical cell in the treatment of acetaminophen containing wastewater. The Box–Behnken design was used to determine the effects of initial Fe 2+ and H 2 O 2 concentrations and applied current density. Results showed that all parameters positively affected the degradation efficiency of acetaminophen with the initial Fe 2+ concentration being the most significant parameter for both processes. The acetaminophen removal efficiency for electro-Fenton was 98% and chemical oxygen demand (COD) removal of 43% while a 97% acetaminophen removal and 42% COD removal were observed for the photoelectro-Fenton method operated at optimum conditions. The electro-Fenton process was only able to obtain 19% total organic carbon (TOC) removal while the photoelectro-Fenton process obtained 20%. Due to negligible difference between the treatment efficiencies of the two processes, the electro-Fenton method was proven to be more economically advantageous. The models obtained from the study were applicable to a wide range of acetaminophen concentrations and can be used in scale-ups. Thirteen different types of intermediates were identified and a degradation pathway was proposed.

  1. Treatment of reverse osmosis (RO) concentrate by the combined Fe/Cu/air and Fenton process (1stFe/Cu/air-Fenton-2ndFe/Cu/air).

    Science.gov (United States)

    Ren, Yi; Yuan, Yue; Lai, Bo; Zhou, Yuexi; Wang, Juling

    2016-01-25

    To decompose or transform the toxic and refractory reverse osmosis (RO) concentrate and improve the biodegradability, 1stFe/Cu/air-Fenton-2ndFe/Cu/air were developed to treat RO concentrate obtained from an amino acid production plant in northern China. First, their operating conditions were optimized thoroughly. Furthermore, 5 control experiments were setup to confirm the superiority of 1stFe/Cu/air-Fenton-2ndFe/Cu/air and synergistic reaction between Fe/Cu/air and Fenton. The results suggest that the developed method could obtain high COD removal (65.1%) and BOD5/COD ratio (0.26) due to the synergistic reaction between Fe/Cu/air and Fenton. Under the optimal conditions, the influent and effluent of 1stFe/Cu/air-Fenton-2ndFe/Cu/air and 5 control experiments were analyzed by using UV, FTIR, EEM and LC, which confirm the superiority of 1stFe/Cu/air-Fenton-2ndFe/Cu/air. Therefore, the developed method in this study is a promising process for treatment of RO concentrate. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Municipal solid waste landfill leachate treatment by fenton, photo-fenton and fenton-like processes: Effect of some variables

    OpenAIRE

    Zazouli, Mohammad Ali; Yousefi, Zabihollah; Eslami, Akbar; Ardebilian, Maryam Bagheri

    2012-01-01

    Abstract Advanced oxidation processes like Fenton and photo-Fenton have been effectively applied to oxidize the persistent organic compounds in solid waste leachate and convert them to unharmful materials and products. However, there are limited data about application of Fenton-like process in leachate treatment. Therefore, this study was designed with the objective of treating municipal landfill leachate by Fenton, Fenton-like and photo–Fenton processes to determine the effect of different v...

  3. Acetaminophen degradation by electro-Fenton and photoelectro-Fenton using a double cathode electrochemical cell

    Energy Technology Data Exchange (ETDEWEB)

    Luna, Mark Daniel G. de [Department of Chemical Engineering, University of the Philippines, 1011 Diliman, Quezon City (Philippines); Environmental Engineering Graduate Program, University of the Philippines, 1011 Diliman, Quezon City (Philippines); Veciana, Mersabel L. [Environmental Engineering Graduate Program, University of the Philippines, 1011 Diliman, Quezon City (Philippines); Su, Chia-Chi [Department of Environmental Resources Management, Chia Nan University of Pharmacy and Science, Tainan 717, Taiwan (China); Lu, Ming-Chun, E-mail: mmclu@mail.chan.edu.tw [Department of Environmental Resources Management, Chia Nan University of Pharmacy and Science, Tainan 717, Taiwan (China)

    2012-05-30

    Highlights: Black-Right-Pointing-Pointer The electro-Fenton reactor using a double cathode electrochemical cell was applied. Black-Right-Pointing-Pointer The initial Fe{sup 2+} concentration was the most significant parameter for the acetaminophen degradation. Black-Right-Pointing-Pointer Thirteen intermediates were identified and a degradation pathway was proposed. - Abstract: Acetaminophen is a widely used drug worldwide and is one of the most frequently detected in bodies of water making it a high priority trace pollutant. This study investigated the applicability of the electro-Fenton and photoelectro-Fenton processes using a double cathode electrochemical cell in the treatment of acetaminophen containing wastewater. The Box-Behnken design was used to determine the effects of initial Fe{sup 2+} and H{sub 2}O{sub 2} concentrations and applied current density. Results showed that all parameters positively affected the degradation efficiency of acetaminophen with the initial Fe{sup 2+} concentration being the most significant parameter for both processes. The acetaminophen removal efficiency for electro-Fenton was 98% and chemical oxygen demand (COD) removal of 43% while a 97% acetaminophen removal and 42% COD removal were observed for the photoelectro-Fenton method operated at optimum conditions. The electro-Fenton process was only able to obtain 19% total organic carbon (TOC) removal while the photoelectro-Fenton process obtained 20%. Due to negligible difference between the treatment efficiencies of the two processes, the electro-Fenton method was proven to be more economically advantageous. The models obtained from the study were applicable to a wide range of acetaminophen concentrations and can be used in scale-ups. Thirteen different types of intermediates were identified and a degradation pathway was proposed.

  4. Electro-Fenton, UVA photoelectro-Fenton and solar photoelectro-Fenton degradation of the drug ibuprofen in acid aqueous medium using platinum and boron-doped diamond anodes

    Energy Technology Data Exchange (ETDEWEB)

    Skoumal, Marcel; Rodriguez, Rosa Maria; Cabot, Pere Lluis; Centellas, Francesc; Garrido, Jose Antonio; Arias, Conchita [Laboratori d' Electroquimica dels Materials i del Medi Ambient, Departament de Quimica Fisica, Facultat de Quimica, Universitat de Barcelona, Marti i Franques 1-11, 08028 Barcelona (Spain); Brillas, Enric [Laboratori d' Electroquimica dels Materials i del Medi Ambient, Departament de Quimica Fisica, Facultat de Quimica, Universitat de Barcelona, Marti i Franques 1-11, 08028 Barcelona (Spain)], E-mail: brillas@ub.edu

    2009-02-28

    The degradation of a 41 mg dm{sup -3} ibuprofen (2-(4-isobutylphenyl)propionic acid) solution of pH 3.0 has been comparatively studied by electrochemical advanced oxidation processes (EAOPs) like electro-Fenton, UVA photoelectro-Fenton and solar photoelectro-Fenton at constant current density. Experiments were performed in a one-compartment cell with a Pt or boron-doped diamond (BDD) anode and an O{sub 2}-diffusion cathode. Heterogeneous hydroxyl radical ({center_dot}OH) is generated at the anode surface from water oxidation, while homogeneous {center_dot}OH is formed from Fenton's reaction between Fe{sup 2+} and H{sub 2}O{sub 2} generated at the cathode, being its production strongly enhanced from photo-Fenton reaction induced by sunlight. Higher mineralization is attained in all methods using BDD instead Pt, because the former produces greater quantity of {center_dot}OH enhancing the oxidation of pollutants. The mineralization rate increases under UVA and solar irradiation by the rapid photodecomposition of complexes of Fe(III) with acidic intermediates. The most potent method is solar photoelectro-Fenton with BDD giving 92% mineralization due to the formation of a small proportion of highly persistent final by-products. The effect of Fe{sup 2+} content, pH and current density on photoelectro-Fenton degradation has been studied. The ibuprofen decay always follows a pseudo-first-order kinetics and its destruction rate is limited by current density and UV intensity. Aromatics such as 1-(1-hydroxyethyl)-4-isobutylbenzene, 4-isobutylacetophenone, 4-isobutylphenol and 4-ethylbenzaldehyde, and carboxylic acids such as pyruvic, acetic, formic and oxalic have been identified as oxidation by-products. Oxalic acid is the ultimate by-product and the fast photodecarboxylation of its complexes with Fe(III) under UVA or solar irradiation explains the higher oxidation power of photoelectro-Fenton methods in comparison to electro-Fenton procedures.

  5. Electro-Fenton, UVA photoelectro-Fenton and solar photoelectro-Fenton degradation of the drug ibuprofen in acid aqueous medium using platinum and boron-doped diamond anodes

    International Nuclear Information System (INIS)

    Skoumal, Marcel; Rodriguez, Rosa Maria; Cabot, Pere Lluis; Centellas, Francesc; Garrido, Jose Antonio; Arias, Conchita; Brillas, Enric

    2009-01-01

    The degradation of a 41 mg dm -3 ibuprofen (2-(4-isobutylphenyl)propionic acid) solution of pH 3.0 has been comparatively studied by electrochemical advanced oxidation processes (EAOPs) like electro-Fenton, UVA photoelectro-Fenton and solar photoelectro-Fenton at constant current density. Experiments were performed in a one-compartment cell with a Pt or boron-doped diamond (BDD) anode and an O 2 -diffusion cathode. Heterogeneous hydroxyl radical (·OH) is generated at the anode surface from water oxidation, while homogeneous ·OH is formed from Fenton's reaction between Fe 2+ and H 2 O 2 generated at the cathode, being its production strongly enhanced from photo-Fenton reaction induced by sunlight. Higher mineralization is attained in all methods using BDD instead Pt, because the former produces greater quantity of ·OH enhancing the oxidation of pollutants. The mineralization rate increases under UVA and solar irradiation by the rapid photodecomposition of complexes of Fe(III) with acidic intermediates. The most potent method is solar photoelectro-Fenton with BDD giving 92% mineralization due to the formation of a small proportion of highly persistent final by-products. The effect of Fe 2+ content, pH and current density on photoelectro-Fenton degradation has been studied. The ibuprofen decay always follows a pseudo-first-order kinetics and its destruction rate is limited by current density and UV intensity. Aromatics such as 1-(1-hydroxyethyl)-4-isobutylbenzene, 4-isobutylacetophenone, 4-isobutylphenol and 4-ethylbenzaldehyde, and carboxylic acids such as pyruvic, acetic, formic and oxalic have been identified as oxidation by-products. Oxalic acid is the ultimate by-product and the fast photodecarboxylation of its complexes with Fe(III) under UVA or solar irradiation explains the higher oxidation power of photoelectro-Fenton methods in comparison to electro-Fenton procedures

  6. Oil refinery wastewater treatment using physicochemical, Fenton and Photo-Fenton oxidation processes.

    Science.gov (United States)

    Tony, Maha A; Purcell, Patrick J; Zhao, Yaqian

    2012-01-01

    The objective of this study was to investigate the application of advanced oxidation processes (AOPs) to the treatment of wastewaters contaminated with hydrocarbon oil. Three different oil-contaminated wastewaters were examined and compared: (i) a 'real' hydrocarbon wastewater collected from an oil refinery (Conoco-Phillips Whitegate refinery, County Cork, Ireland); (ii) a 'real' hydrocarbon wastewater collected from a car-wash facility located at a petroleum filling station; and (iii) a 'synthetic' hydrocarbon wastewater generated by emulsifying diesel oil and water. The AOPs investigated were Fe(2+)/H(2)O(2) (Fenton's reagent), Fe(2+)/H(2)O(2)/UV (Photo-Fenton's reagent) which may be used as an alternative to, or in conjunction with, conventional treatment techniques. Laboratory-scale batch and continuous-flow experiments were undertaken. The photo-Fenton parametric concentrations to maximize COD removal were optimized: pH = 3, H(2)O(2) = 400 mg/L, and Fe(2+) = 40 mg/L. In the case of the oil-refinery wastewater, photo-Fenton treatment achieved approximately 50% COD removal and, when preceded by physicochemical treatment, the percentage removal increased to approximately 75%.

  7. Optimizing the treatment of landfill leachate by conventional Fenton and photo-Fenton processes

    International Nuclear Information System (INIS)

    Hermosilla, Daphne; Cortijo, Manuel; Huang, Chin Pao

    2009-01-01

    Landfill, a matured and economically appealing technology, is the ultimate approach for the management of municipal solid wastes. However, the inevitable generation of leachate from landfill requires further treatment. Among the various leachate treatment technologies available, advanced oxidation processes (AOPs) are among powerful methods to deal with the refractory organic constituents, and the Fenton reagent has evolved as one promising AOPs for the treatment of leachates. Particularly, the combination of UV-radiation with Fenton's reagent has been reported to be a method that allows both the photo-regeneration of Fe 2+ and photo-decarboxylation of ferric carboxylates. In this study, Fenton and photo-Fenton processes were fine tuned for the treatment of leachates from the Colmenar Viejo (Madrid, Spain) Landfill. Results showed that it is possible to define a set of conditions under which the same COD and TOC removals (approx 70%) could be achieved with both the conventional and photo-Fenton processes. But Fenton process generated an important quantity of iron sludge, which will require further disposal, when performed under optimal COD removal conditions. Furthermore conventional Fenton process was able to achieve slightly over an 80% COD removal from a 'young' leachate, while for 'old' and 'mixed' leachates was close to a 70%. The main advantage showed by the photo-assisted Fenton treatment of landfill leachate was that it consumed 32 times less iron and produced 25 times less sludge volume yielding the same COD removal results than a conventional Fenton treatment.

  8. Mineralization of hetero bi-functional reactive dye in aqueous solution by Fenton and photo-Fenton reactions.

    Science.gov (United States)

    Torrades, Francesc; García-Hortal, José Antonio; García-Montaño, Julia

    2015-01-01

    This study focused on the advanced oxidation of the hetero bi-functional reactive dye Sumifix Supra Yellow 3RF (CI Reactive Yellow 145) using dark Fenton and photo-Fenton conditions in a lab-scale experiment. A 2(3) factorial design was used to evaluate the effects of the three key factors: temperature, Fe(II) and H2O2 concentrations, for a dye concentration of 250 mg L(-1) with chemical oxygen demand (COD) of 172 mg L(-1) O2 at pH=3. The response function was the COD reduction. This methodology lets us find the effects and interactions of the studied variables and their roles in the efficiency of the treatment process. In the optimization, the correlation coefficients for the model (R2) were 0.948 and 0.965 for Fenton and photo-Fenton treatments, respectively. Under optimized reaction conditions: pH=3, temperature=298 K, [H2O2]=11.765 mM and [Fe(II)]=1.075 mM; 60 min of treatment resulted in a 79% and 92.2% decrease in COD, for the dye taken as the model organic compound, after Fenton and photo-Fenton treatments, respectively.

  9. Determining the optimal dose of Fenton reagent in a leachate treatment by Fenton-adsorption; Determinacion de la dosis optima de reactivo Fenton en un tratamiento de lixiviados por Fenton-adsorcion

    Energy Technology Data Exchange (ETDEWEB)

    Mendez Novelo, Roger Ivan; Pietrogiovanna Bronca, Jose Alfredo; Santos Ocampo, Beatriz; Sauri Riancho, Maria Rosa; Giacoman Vallejos, German; Castillo Borges, Elba Rene [Universidad Autonoma de Yucatan, Facultad de Ingenieria, Merida, Yucatan (Mexico)]. E-mail: mnovelo@uady.mx

    2010-07-01

    Leachates are formed as a result of the percolation of liquids, through the solid wastes in stabilization process. Their composition is variable and highly toxic; therefore, leachates treatment is a complex task. Due to the high permeability of the soil of the Yucatan Peninsula leachates represent a high risk to health. Fenton type oxidation and adsorption treatment have been tested, and they have showed better results than other types of biological or physicochemical treatment. Fenton process consists in treating the contaminant load with a combination of H{sub 2}O{sub 2} and FeSO{sub 4} under acidic conditions. Experiments were conducted in order to determine if filtration was better than the sedimentation of the sludges. The optimum contact time and the best relations [Fe{sup 2+}]/[H{sub 2}O{sub 2}] and [COD]/[H{sub 2}O{sub 2}] were determined. Subsequently, the oxidized samples were filtered and the adsorption process was tested using two columns in series packed with activated carbon. It was concluded that the sludge generated by the Fenton process was removed more efficiently through filtration than sedimentation. Optimal contact times were 5 min for COD removal, and 1 hour for colour removal; process time was set to one hour in order to protect the activated carbon. The best relations for [Fe{sup 2+}]/[H{sub 2}O{sub 2}] and [COD]/[H{sub 2}O{sub 2}] were 0.6 and 9 respectively. The maximum removal efficiency after the adsorption process was 98.9% for COD and 100% for colour at zero time of the column. A final biodegradability index of 0.24 was reached after the Fenton-adsorption tests. [Spanish] Los lixiviados son el resultado de la percolacion de liquidos a traves de los desechos solidos en proceso de estabilizacion. La complejidad de su tratamiento se debe a que su composicion es altamente toxica y variable. Lo anterior y el suelo altamente permeable de la peninsula de Yucatan, representan un alto peligro a la salud. Se ensayo un tratamiento de oxidacion

  10. Optimizing the treatment of landfill leachate by conventional Fenton and photo-Fenton processes

    Energy Technology Data Exchange (ETDEWEB)

    Hermosilla, Daphne, E-mail: dhermosilla@quim.ucm.es [Departamento de Ingenieria Quimica, Facultad de Ciencias Quimicas, Universidad Complutense de Madrid, Ciudad Universitaria s/n, 28040 Madrid (Spain); Cortijo, Manuel [U.D. Operaciones Basicas, Departamento de Ingenieria Forestal, E.T.S.I. Montes, Universidad Politecnica de Madrid, Avda. Ramiro de Maeztu s/n, 28040 Madrid (Spain); Huang, Chin Pao [Department of Civil and Environmental Engineering, 352C DuPont Hall, University of Delaware, Newark, DE 19716 (United States)

    2009-05-15

    Landfill, a matured and economically appealing technology, is the ultimate approach for the management of municipal solid wastes. However, the inevitable generation of leachate from landfill requires further treatment. Among the various leachate treatment technologies available, advanced oxidation processes (AOPs) are among powerful methods to deal with the refractory organic constituents, and the Fenton reagent has evolved as one promising AOPs for the treatment of leachates. Particularly, the combination of UV-radiation with Fenton's reagent has been reported to be a method that allows both the photo-regeneration of Fe{sup 2+} and photo-decarboxylation of ferric carboxylates. In this study, Fenton and photo-Fenton processes were fine tuned for the treatment of leachates from the Colmenar Viejo (Madrid, Spain) Landfill. Results showed that it is possible to define a set of conditions under which the same COD and TOC removals (approx 70%) could be achieved with both the conventional and photo-Fenton processes. But Fenton process generated an important quantity of iron sludge, which will require further disposal, when performed under optimal COD removal conditions. Furthermore conventional Fenton process was able to achieve slightly over an 80% COD removal from a 'young' leachate, while for 'old' and 'mixed' leachates was close to a 70%. The main advantage showed by the photo-assisted Fenton treatment of landfill leachate was that it consumed 32 times less iron and produced 25 times less sludge volume yielding the same COD removal results than a conventional Fenton treatment.

  11. Identification of intermediates, acute toxicity removal, and kinetics investigation to the Ametryn treatment by direct photolysis (UV254), UV254/H2O2, Fenton, and photo-Fenton processes.

    Science.gov (United States)

    de Oliveira, Dirce Martins; Cavalcante, Rodrigo Pereira; da Silva, Lucas de Melo; Sans, Carme; Esplugas, Santiago; de Oliveira, Silvio Cesar; Junior, Amilcar Machulek

    2018-02-09

    This paper reports the degradation of 10 mg L -1 Ametryn solution with different advanced oxidation processes and by ultraviolet (UV 254 ) irradiation alone with the main objective of reducing acute toxicity and increase biodegradability. The investigated factors included Fe 2+ and H 2 O 2 concentrations. The effectiveness of the UV 254 and UV 254 /H 2 O 2 processes were investigated using a low-pressure mercury UV lamp (254 nm). Photo-Fenton process was explored using a blacklight blue lamp (BLB, λ = 365 nm). The UV 254 irradiation process achieved complete degradation of Ametryn solution after 60 min. The degradation time of Ametryn was greatly improved by the addition of H 2 O 2 . It is worth pointing out that a high rate of Ametryn removal was attained even at low concentrations of H 2 O 2 . The kinetic constant of the reaction between Ametryn and HO ● for UV 254 /H 2 O 2 was 3.53 × 10 8  L mol -1  s -1 . The complete Ametryn degradation by the Fenton and photo-Fenton processes was observed following 10 min of reaction for various combinations of Fe 2+ and H 2 O 2 under investigation. Working with the highest concentration (150 mg L -1 H 2 O 2 and 10 mg L -1 Fe 2+ ), around 30 and 70% of TOC removal were reached within 120 min of treatment by Fenton and photo-Fenton processes, respectively. Although it did not obtain complete mineralization, the intermediates formed in the degradation processes were hydroxylated and did not promote acute toxicity of Vibrio fischeri. Furthermore, a substantial improvement of biodegradability was obtained for all studied processes.

  12. Treating leachate by Fenton oxidation

    Directory of Open Access Journals (Sweden)

    Roger Iván Méndez Novelo

    2010-01-01

    Full Text Available Leachates are formed from liquids, mainly rainwater, percolating through solid wastes during stabilisation. Their composition is variable and highly toxic; leachate treatment is therefore a complex task. Leachates represent a high risk to health due to the Yucatan Peninsula’s highly permeable soil. The results are presented from applying the Fenton process to treating leachate from the sanitary Merida landfill, Yucatan, Mexico. The Fenton process consists of treating the contaminant load with an H2O2 and FeSO4 combination in acidic conditions. Optimal reaction time, pH value, Fenton reagent dose, post treatment coagulation – flocculation doses and increased biodegradability index were all determined. Optimal oxidation conditions and doses were 202+ minute contact time, 4 pH, 600 mg/L H2O2 concentration and 1,000 mg/L Fe. Average organic matter removal rate, measured as CODS and TOC, were 78% and 87% respectively. The biodegradability index increased from 0.07 to 0.11 during the Fenton process and up to 0.13 when the Fenton process was followed by coagulation-flocculation.

  13. Degradation of flumequine by the Fenton and photo-Fenton processes: Evaluation of residual antimicrobial activity

    International Nuclear Information System (INIS)

    Rodrigues-Silva, Caio; Maniero, Milena Guedes; Rath, Susanne; Guimarães, José Roberto

    2013-01-01

    Flumequine is a broad-spectrum antimicrobial agent of the quinolone class, and it is widely used as a veterinary drug in food-producing animals. The presence of flumequine in the environment may contribute to the development of drug resistant bacterial strains. In this study, water samples fortified with flumequine (500 μg L −1 ) were degraded using the Fenton and photo-Fenton processes. The maximum degradation efficiency for flumequine by the Fenton process was approximately 40% (0.5 mmol L −1 Fe(II), 2.0 mmol L −1 H 2 O 2 and 15 min). By applying UV radiation (photo-Fenton process), the efficiency reached more than 94% in 60 min when 0.25 mmol L −1 Fe(II) and 10.0 mmol L −1 H 2 O 2 were used. Under these conditions, the Fenton process was able to reduce the biological activity, whereas the photo-Fenton process eliminated almost all of the antimicrobial activity because it was not detected. Four byproducts with an m/z of 244, 238, 220 and 202 were identified by mass spectrometry, and a degradation pathway for flumequine was proposed. The byproducts were derived from decarboxylation and defluorination reactions and from modifications in the alkylamino chain of the fluoroquinolone. - Highlights: ► Photo-Fenton process achieved the maximum performance, degrading 94% of flumequine. ► As the flumequine concentration decreased, antimicrobial activity also decreased. ► Four byproducts with m/z of 244, 238, 220 and 202 were identified. ► A degradation pathway for flumequine was proposed

  14. GT-MHR project

    International Nuclear Information System (INIS)

    Kiryushin, A.; Kodochigov, N.

    2002-01-01

    The paper presents new generation reactor - modular helium reactor with gas turbine (GT-MHR), which satisfies the requirements of the developing nuclear power. The paper describes the reactor plant and peculiarities of GT-MHR technical concept, such as high efficiency (about 48%) of electric power generation, increased safety of the plant, etc. The technologies, which are the innovative essence of GT-MHR project, are: (1) fuel in the form of fuel particles with multi-layer ceramic coatings which confine fission products at high temperatures (of about 1600 deg.); (2) large gas turbines; (3) single-shaft vertical turbomachine design; (4) electromagnetic bearings; (5) high-effective compact heat exchangers. Main technical and economical indices of GT-MHR project are presented. (author)

  15. Comparative study of oxidation of dye-Reactive Black B by different advanced oxidation processes: Fenton, electro-Fenton and photo-Fenton

    International Nuclear Information System (INIS)

    Huang Yaohui; Huang Yifong; Chang Poshun; Chen Chuhyung

    2008-01-01

    This study makes a comparison between photo-Fenton and a novel electro-Fenton called Fered-Fenton to study the mineralization of 10,000 mg/L of dye-Reactive Black B (RBB) aqueous solution, which was chosen as the model dye contaminant. Results indicate that the traditional Fenton process only yields 70% mineralization. This result can be improved by using Fered-Fenton to yield 93% mineralization resulting from the action of ferrous ion regenerated on the cathode. Furthermore, photo-Fenton allows a fast and more complete destruction of dye solutions and as a result of the action of ferrous ion regenerated by UV irradiation yields more than 98% mineralization. In all treatments, the RBB is rapidly decayed to some carboxylic acid intermediates. The major intermediates found are formic acid and oxalic acid. This study finds that formic acid can be completely mineralized by photo-Fenton, but its destruction is problematic using the Fenton method. Oxalic acid is much more difficult to treat than other organic acids. It could get further mineralization with the use of the Fered-Fenton process

  16. Degradation of flumequine by the Fenton and photo-Fenton processes: Evaluation of residual antimicrobial activity

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues-Silva, Caio; Maniero, Milena Guedes [School of Civil Engineering, Architecture and Urbanism, University of Campinas — UNICAMP, P.O. Box 6021, CEP 13083-852, Campinas, SP (Brazil); Rath, Susanne [Chemistry Institute, University of Campinas — UNICAMP, P.O. Box 6154, CEP 13084-971, Campinas, SP (Brazil); Guimarães, José Roberto, E-mail: jorober@fec.unicamp.br [School of Civil Engineering, Architecture and Urbanism, University of Campinas — UNICAMP, P.O. Box 6021, CEP 13083-852, Campinas, SP (Brazil)

    2013-02-15

    Flumequine is a broad-spectrum antimicrobial agent of the quinolone class, and it is widely used as a veterinary drug in food-producing animals. The presence of flumequine in the environment may contribute to the development of drug resistant bacterial strains. In this study, water samples fortified with flumequine (500 μg L{sup −1}) were degraded using the Fenton and photo-Fenton processes. The maximum degradation efficiency for flumequine by the Fenton process was approximately 40% (0.5 mmol L{sup −1} Fe(II), 2.0 mmol L{sup −1} H{sub 2}O{sub 2} and 15 min). By applying UV radiation (photo-Fenton process), the efficiency reached more than 94% in 60 min when 0.25 mmol L{sup −1} Fe(II) and 10.0 mmol L{sup −1} H{sub 2}O{sub 2} were used. Under these conditions, the Fenton process was able to reduce the biological activity, whereas the photo-Fenton process eliminated almost all of the antimicrobial activity because it was not detected. Four byproducts with an m/z of 244, 238, 220 and 202 were identified by mass spectrometry, and a degradation pathway for flumequine was proposed. The byproducts were derived from decarboxylation and defluorination reactions and from modifications in the alkylamino chain of the fluoroquinolone. - Highlights: ► Photo-Fenton process achieved the maximum performance, degrading 94% of flumequine. ► As the flumequine concentration decreased, antimicrobial activity also decreased. ► Four byproducts with m/z of 244, 238, 220 and 202 were identified. ► A degradation pathway for flumequine was proposed.

  17. Removal of azo dye using Fenton and Fenton-like processes: Evaluation of process factors by Box-Behnken design and ecotoxicity tests.

    Science.gov (United States)

    Fernandes, Neemias Cintra; Brito, Lara Barroso; Costa, Gessyca Gonçalves; Taveira, Stephânia Fleury; Cunha-Filho, Marcílio Sérgio Soares; Oliveira, Gisele Augusto Rodrigues; Marreto, Ricardo Neves

    2018-06-06

    The conventional treatment of textile effluents is usually inefficient in removing azo dyes and can even generate more toxic products than the original dyes. The aim of the present study was to optimize the process factors in the degradation of Disperse Red 343 by Fenton and Fenton-like processes, as well as to investigate the ecotoxicity of the samples treated under optimized conditions. A Box-Behnken design integrated with the desirability function was used to optimize dye degradation, the amount of residual H 2 O 2 [H 2 O 2residual ], and the ecotoxicity of the treated samples (lettuce seed, Artemia salina, and zebrafish in their early-life stages). Dye degradation was affected only by catalyst concentration [Fe] in both the Fenton and Fenton-like processes. In the Fenton reaction, [H 2 O 2residual ] was significantly affected by initial [H 2 O 2 ] and its interaction with [Fe]; however, in the Fenton-like reaction, it was affected by initial [H 2 O 2 ] only. A. salina mortality was affected by different process factors in both processes, which suggests the formation of different toxic products in each process. The desirability function was applied to determine the best process parameters and predict the responses, which were confirmed experimentally. Optimal conditions facilitated the complete degradation of the dye without [H 2 O 2residual ] or toxicity for samples treated with the Fenton-like process, whereas the Fenton process induced significant mortality for A. salina. Results indicate that the Fenton-like process is superior to the Fenton reaction to degrade Disperse Red 343. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Advancing Fenton and photo-Fenton water treatment through the catalyst design.

    Science.gov (United States)

    Vorontsov, Alexander V

    2018-04-20

    The review is devoted to modern Fenton, photo-Fenton, as well as Fenton-like and photo-Fenton-like reactions with participation of iron species in liquid phase and as heterogeneous catalysts. Mechanisms of these reactions were considered that include hydroxyl radical and oxoferryl species as the reactive intermediates. The barriers in the way of application of these reactions to wastewater treatment were discussed. The following fundamental problems need further research efforts: inclusion of more mechanism steps and quantum calculations of all rate constants lacking in the literature, checking the outer sphere electron transfer contribution, determination of the causes for the key changes in the homogeneous Fenton reaction mechanism with a change in the reagents concentration. The key advances for Fenton reactions implementation for the water treatment are related to tremendous hydrodynamical effects on the catalytic activity, design of ligands for high rate and completeness of mineralization in short time, and design of highly active heterogeneous catalysts. While both homogeneous and heterogeneous Fenton and photo-Fenton systems are open for further improvements, heterogeneous photo-Fenton systems are most promising for practical applications because of the inherent higher catalyst stability. Modern methods of quantum chemistry are expected to play a continuously increasing role in development of such catalysts. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Comparison of Fenton and sono-Fenton bisphenol A degradation

    International Nuclear Information System (INIS)

    Ioan, Iordache; Wilson, Steven; Lundanes, Elsa; Neculai, Aelenei

    2007-01-01

    Degradation of bisphenol A (BPA) was carried out with the Fenton reagent with and without additional sonochemical treatment. The Fenton and the sono-Fenton decomposition of BPA showed that ultrasound irradiation of wastewater improved the wet oxidation process of 25 mg l -1 BPA solutions. The sonochemical degradation of BPA was monitored using UV absorption and large volume injection packed capillary LC measurements

  20. Mature landfill leachate treatment by coagulation/flocculation combined with Fenton and solar photo-Fenton processes.

    Science.gov (United States)

    Amor, Carlos; De Torres-Socías, Estefanía; Peres, José A; Maldonado, Manuel I; Oller, Isabel; Malato, Sixto; Lucas, Marco S

    2015-04-09

    This work reports the treatment of a mature landfill leachate through the application of chemical-based treatment processes in order to achieve the discharge legal limits into natural water courses. Firstly, the effect of coagulation/flocculation with different chemicals was studied, evaluating the role of different initial pH and chemicals concentration. Afterwards, the efficiency of two different advanced oxidation processes for leachate remediation was assessed. Fenton and solar photo-Fenton processes were applied alone and in combination with a coagulation/flocculation pre-treatment. This physicochemical conditioning step, with 2 g L(-1) of FeCl3 · 6H2O at pH 5, allowed removing 63% of COD, 80% of turbidity and 74% of total polyphenols. Combining the coagulation/flocculation pre-treatment with Fenton reagent, it was possible to reach 89% of COD removal in 96 h. Moreover, coagulation/flocculation combined with solar photo-Fenton revealed higher DOC (75%) reductions than single solar photo-Fenton (54%). In the combined treatment (coagulation/flocculation and solar photo-Fenton), it was reached a DOC reduction of 50% after the chemical oxidation, with 110 kJ L(-1) of accumulated UV energy and a H2O2 consumption of 116 mM. Toxicity and biodegradability assays were performed to evaluate possible variations along the oxidation processes. After the combined treatment, the leachate under study presented non-toxicity but biodegradability increased. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Design of a neutral electro-Fenton system with Fe-Fe2O3/ACF composite cathode for wastewater treatment

    International Nuclear Information System (INIS)

    Li Jinpo; Ai Zhihui; Zhang Lizhi

    2009-01-01

    The narrow pH range limits the wide application of Fenton reaction in the wastewater treatment. It is of great importance to widen working pH range of Fenton reaction from strong acidic condition to neutral, even basic ones. In this study, for the first time nanostructured Fe-Fe 2 O 3 was loaded on active carbon fiber (ACF) as an oxygen diffusion cathode to be used in a heterogeneous electro-Fenton (E-Fenton) oxidation system. This novel Fe-Fe 2 O 3 /ACF composite cathode was characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), energy dispersive X-ray (EDX) analysis, transmission electron microscopy (TEM), and element mapping. On the degradation of dye pollutant rhodamine B in water, this heterogeneous E-Fenton system with the Fe-Fe 2 O 3 /ACF cathode showed much higher activity than other E-Fenton systems with commercial zero valent iron powders (Fe 0 ) and ferrous ions (Fe 2+ ) under neutral pH. On the basis of experimental results, we proposed a possible pathway of rhodamine B degradation in this heterogeneous Fe-Fe 2 O 3 /ACF E-Fenton process. This heterogeneous E-Fenton system is very promising to remove organic pollutants in water at neutral pH

  2. Pretreatment of furfural industrial wastewater by Fenton, electro-Fenton and Fe(II)-activated peroxydisulfate processes: a comparative study.

    Science.gov (United States)

    Yang, C W; Wang, D; Tang, Q

    2014-01-01

    The Fenton, electro-Fenton and Fe(II)-activated peroxydisulfate (PDS) processes have been applied for the treatment of actual furfural industrial wastewater in this paper. Through the comparative study of the three processes, a suitable pretreatment technology for actual furfural wastewater treatment was obtained, and the mechanism and dynamics process of this technology is discussed. The experimental results show that Fenton technology has a good and stable effect without adjusting pH of furfural wastewater. At optimal conditions, which were 40 mmol/L H₂O₂ initial concentration and 10 mmol/L Fe²⁺ initial concentration, the chemical oxygen demand (COD) removal rate can reach 81.2% after 90 min reaction at 80 °C temperature. The PDS process also has a good performance. The COD removal rate could attain 80.3% when Na₂S₂O₈ initial concentration was 4.2 mmol/L, Fe²⁺ initial concentration was 0.1 mol/L, the temperature remained at 70 °C, and pH value remained at 2.0. The electro-Fenton process was not competent to deal with the high-temperature furfural industrial wastewater and only 10.2% COD was degraded at 80 °C temperature in the optimal conditions (2.25 mA/cm² current density, 4 mg/L Na₂SO₄, 0.3 m³/h aeration rate). For the Fenton, electro-Fenton and PDS processes in pretreatment of furfural wastewater, their kinetic processes follow the pseudo first order kinetics law. The pretreatment pathways of furfural wastewater degradation are also investigated in this study. The results show that furfural and furan formic acid in furfural wastewater were preferentially degraded by Fenton technology. Furfural can be degraded into low-toxicity or nontoxic compounds by Fenton pretreatment technology, which could make furfural wastewater harmless and even reusable.

  3. Fenton-like oxidation of 2,4-DCP in aqueous solution using iron-based nanoparticles as the heterogeneous catalyst.

    Science.gov (United States)

    Li, Renchao; Gao, Ying; Jin, Xiaoying; Chen, Zuliang; Megharaj, Mallavarapu; Naidu, Ravendra

    2015-01-15

    In this report, various iron-based nanoparticles (nZVI, n-Ni/Fe, n-Pd/Fe) were used for both heterogeneous Fenton oxidation of 2,4-dichlorophenol (2,4-DCP) and reductive dechlorination of 2,4-DCP in order to understand their roles in the Fenton oxidation and the reductive degradation of 2,4-DCP. The dechlorination efficiency of 2,4-DCP using nZVI, n-Ni/Fe, n-Fe/Pd and Fe(2)(+) was 6.48%, 6.80%, 15.95%, 5.02%, while Fenton oxidation efficiency of 2,4-DCP was 57.87%, 34.23%, 27.94%, 19.61% after 180 min, respectively. The new findings included a higher dechlorination using n-Fe/Pd due to Pd effective catalysis and the effective heterogeneous Fenton oxidation using nZVI depending on reductive dechlorination and heterogeneous Fenton oxidation occurs simultaneously. However, nZVI as the potential catalyst for heterogeneous Fenton was observed, and SEM, EDS and XRD demonstrate that change on the nZVI surface occurred due to the Fe(2+) leaching, and Total Organic Carbon (TOC) (30.71%) shows that 2,4-DCP was degraded. Furthermore, the experiment indicates that the pH values and concentration of 2,4-DCP significantly impacted on the heterogeneous Fenton oxidation of 2,4-DCP and the data fits well with the pseudo first-order kinetic model, which was a diffusion-controlled reaction. Finally, a possible mechanism for degradation of 2,4-DCP was proposed. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Enhancement of Fenton and photo-Fenton processes at initial circumneutral pH for the degradation of the β-blocker metoprolol.

    Science.gov (United States)

    Romero, V; Acevedo, S; Marco, P; Giménez, J; Esplugas, S

    2016-01-01

    The need for acidification in the Fenton and photo-Fenton process is often outlined as one of its major drawbacks, thus in this work the acidification of the Metoprolol (MET) is avoided by the addition of resorcinol (RES), which is used to simulate model organic matter. The experiments were carried out at natural pH (6.2) with different Fe(2+) (1, 2.5, 5, and 10 mg/L) and H2O2 (25, 50, 125 and 150 mg/L) concentrations. The performance of MET and RES degradation was assessed along the reaction time. Working with the highest concentrations (5 and 10 mg/L of ferrous iron and 125 and 150 mg/L of H2O2) more than 90% of MET and RES removals were reached within 50 and 20 min of treatment, respectively, by Fenton process. However a low mineralization was achieved in both cases, likely, due to by-products accumulation. Regarding to photo-Fenton process, within 3 min with the highest iron and hydrogen peroxide concentrations, a complete MET degradation was obtained and 95% of RES conversion was achieved. Parameters such Total Organic Carbon, Chemical Oxygen Demand, and AOS were measured. Intermediates were identified and MET degradation path was proposed in the presence of resorcinol. Finally, a comparison between Fenton and photo-Fenton processes at acid pH and at initial circumneutral pH was discussed. The positive effect of RES on Fenton and photo-Fenton systems has been confirmed, allowing the work at circumneutral pH. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Degradation of organic dyes by a new heterogeneous Fenton reagent - Fe2GeS4 nanoparticle.

    Science.gov (United States)

    Shi, Xiaoguo; Tian, Ang; You, Junhua; Yang, He; Wang, Yuzheng; Xue, Xiangxin

    2018-07-05

    The heterogeneous Fenton system has become the hotspot in the decontamination field due to its effective degradation performance with a wide pH range. Based on the unstable chemical properties of pyrite, in this article, Fe 2 GeS 4 nanoparticles with better thermodynamic stability were prepared by vacuum sintering and high energy ball milling and its potential as Fenton reagent was investigated for the first time. Three determinants of the heterogeneous Fenton system including the iron source, hydrogen peroxide, pH and the degradation mechanism were investigated. The catalyst dosage of 0.3 g/L, initial H 2 O 2 concentration in the Fenton system of 50 m mol/L and pH of 7 were chosen as the best operational conditions. An almost complete degradation was achieved within 5 min for methylene blue and rhodamine b while 10 min for methyl orange. The total organic carbon removal efficiencies of Fe 2 GeS 4 heterogeneous Fenton system for methylene blue, methyl orange and rhodamine b in 10 min were 56.3%, 66.2% and 74.2%, respectively. It's found that the degradation ability could be attributed to a heterogeneous catalysis occurring at the Fe 2 GeS 4 surface together with a homogeneous catalysis in the aqueous phase by the dissolved iron ions. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. PERBANDINGAN EFEKTIFITAS DISINFEKTAN KAPORIT, HIDROGEN PEROKSIDA, DAN PEREAKSI FENTON (H2O2/Fe2+

    Directory of Open Access Journals (Sweden)

    Didik Setiawan

    2013-11-01

    Full Text Available Tujuan dari penelitian ini adalah untuk menentukan konsentrasi optimum dan efektifitas hidrogen peroksida dan pereaksi Fenton sebagai disinfektan dibandingkan dengan kaporit. Efektivitas disinfeksi ditentukan berdasarkan beberapa parameter yaitu: koefisien fenol disinfektan dan kualitas air yang dihasilkan yang diukur melalui pH, oksigen terlarut (DO, dissolved oxygen, dan suhunya serta harga disinfektan itu sendiri. Analisis statistik ANOVA dua arah tanpa interaksi  pada tingkat kesalahan 0.01 dilakukan guna menentukan disinfektan paling efektif dan konsentrasi optimumnya. Uji koefisien fenol dilakukan dengan mencampurkan disinfektan dengan konsentrasi tertentu dengan bakteri Salmonella typhosa dan Staphyllococcus aureuskemudian membandingkan hasilnya dengan fenol.Hasil pengamatan menunjukkan bahwa koefisien fenol dari kaporit, hidrogen peroksida, dan reagen Fenton berturut-turut adalah 4, 6, dan 6. Air yang dihasilkan oleh kaporit mempunyai pH, DO dan suhu berturut-turut adalah 10.07 - 9.2, 6.63-8.07 mgL-1, dan 28.5-28.13oC. Air yang didisinfeksi dengan hidrogen peroksida mempunyai pH,DO, dan suhu berturut-turut adalah 9.03-7.33, 6.93-9.40 mgL-1  , dan 28.5-28.03oC. Sedangkan air hasil didisinfeksi dengan reagen Fenton mempunyai pH, DO, dan suhu berturut-turut adalah 5.97-4.57, 7.40-8.57 mgL-1 , dan 28.47-28.07oC.Meskipun kaporit paling murah, namun dari segi kesehatan hidrogen peroksida merupakan reagen yang paling aman dan paling efektif karena dengan daya disinfeksi enam kali dibandingkan fenol, tidak meninggalkan residu yang membahayakan. Fenton, dilain pihak, meskipun mempunyai daya disinfeksi setara dengan hidrogen peroksida, namun menghasilkan ion Besi (III dalam air sehingga memerlukan pengolahan lebih jauh.Dengan demikian, secara keseluruhan hidrogen peroksida merupakan disinfektan paling efektif dari ketiganya.   The purpose of this study is to determine the optimum concentration and the effectiveness of hydrogen peroxide and

  7. Stabilization of hydrogen peroxide using tartaric acids in Fenton and fenton-like oxidation

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Hyung Suk; Kim, Jeong-Jin; Kim, Young-Hun [Andong National University, Andong (Korea, Republic of)

    2016-03-15

    The stabilization of hydrogen peroxide is a key factor in the efficiency of a Fenton reaction. The stability of hydrogen peroxide was evaluated in a Fenton reaction and Fenton-like reactions in the presence of tartaric acid as a stabilizer. The interactions between ferrous or ferric iron and tartaric acid were observed through spectroscopic monitoring at variable pH around pKa{sub 1} and pKa{sub 2} of the stabilizer. Ferric iron had a strong interaction with the stabilizer, and the strong interaction was dominant above pKa{sub 2}. At a low pH, below pKa{sub 1}, the stabilizing effect was at its maximum and the prolonged life-time of hydrogen peroxide gave a higher efficiency to the oxidative degradation of nitrobenzene. In Fenton-like reactions with hematite, the acidic conditions caused dissolution of iron from an iron oxide, and an increase in iron species was the result. Tartaric acid showed a stabilizing effect on hydrogen peroxide in the Fentonlike system. The stabilization by tartaric acid might be due to an inhibition of catalytic activity of dissolved iron, and the stabilization strongly depends on the ionization state of the stabilizer.

  8. Stabilization of hydrogen peroxide using tartaric acids in Fenton and fenton-like oxidation

    International Nuclear Information System (INIS)

    Oh, Hyung Suk; Kim, Jeong-Jin; Kim, Young-Hun

    2016-01-01

    The stabilization of hydrogen peroxide is a key factor in the efficiency of a Fenton reaction. The stability of hydrogen peroxide was evaluated in a Fenton reaction and Fenton-like reactions in the presence of tartaric acid as a stabilizer. The interactions between ferrous or ferric iron and tartaric acid were observed through spectroscopic monitoring at variable pH around pKa 1 and pKa 2 of the stabilizer. Ferric iron had a strong interaction with the stabilizer, and the strong interaction was dominant above pKa 2 . At a low pH, below pKa 1 , the stabilizing effect was at its maximum and the prolonged life-time of hydrogen peroxide gave a higher efficiency to the oxidative degradation of nitrobenzene. In Fenton-like reactions with hematite, the acidic conditions caused dissolution of iron from an iron oxide, and an increase in iron species was the result. Tartaric acid showed a stabilizing effect on hydrogen peroxide in the Fentonlike system. The stabilization by tartaric acid might be due to an inhibition of catalytic activity of dissolved iron, and the stabilization strongly depends on the ionization state of the stabilizer.

  9. REMEDIATION OF TEXTILE DYES MIXTURES USING TIO2/VIS PHOTOCATALYSIS AND FENTON FE2+/H2O2

    Directory of Open Access Journals (Sweden)

    P. M. Andrade

    2015-12-01

    Full Text Available This study aimed to use the following treatment technology: TiO2 photocatalysis and Fenton reaction for the remediation of mixture of textile dyes.  For the photocatalytic treatment it was obtained a reduction in color of 80% and Chemical Oxygen Demand of 60% using for this 600 mg L-1 of TiO2, 1500  mL min-1 recirculation flow, temperature 40 oC/45 oC and pH = 6.3 for 60 minutes of treatment. By Fenton reaction it was reached color reduction at 95% and Chemical Oxygen Demand reduction at 75% employing 60 mg L-1 H2O2, 50 mg L-1 de Fe2+ and pH = 4.0 for 62 minutes of treatment.

  10. Tertiary treatment of pulp mill wastewater by solar photo-Fenton

    International Nuclear Information System (INIS)

    Lucas, Marco S.; Peres, José A.; Amor, Carlos; Prieto-Rodríguez, Lucía; Maldonado, Manuel I.; Malato, Sixto

    2012-01-01

    Highlights: ► We firstly report a real pulp mill wastewater treatment by solar photo-Fenton in a CPC reactor. Fenton reagent experiments were tested firstly. ► Solar photo-Fenton presents excellent ability to treat the pulp mill wastewater. ► Experimental conditions were optimised. ► Biodegradability and toxicity tests (respirometry assays and BOD 5 /COD ratio) were performed during the wastewater treatment. ► A way to reduce the economic and environmental impact was evaluated. - Abstract: This work reports on pulp mill wastewater (PMW) tertiary treatment by Fenton (Fe 2+ /H 2 O 2 ) and solar photo-Fenton (Fe 2+ /H 2 O 2 /UV) processes in a pilot plant based on compound parabolic collectors (CPCs). Solar photo-Fenton reaction is much more efficient than the respective dark reaction under identical experimental conditions. It leads to DOC mineralisation, COD and total polyphenols (TP) removal higher than 90%. The solar photo-Fenton experiment with 5 mg Fe L −1 reaches 90% of DOC mineralisation with 31 kJ L −1 of UV energy and 50 mM of H 2 O 2 . The initial non-biodegradability of PMW, as shown by respirometry assays and BOD 5 /COD ratio, can be changed after a solar photo-Fenton treatment. Experiments with 20 and 50 mg Fe L −1 revealed that solar photo-Fenton can reach the same DOC degradation (90%), however, consuming less H 2 O 2 and time. Diluting the initial organic load to 50% also diminishes the dosage of H 2 O 2 and the necessary reaction time to achieve high DOC removals. Accordingly, solar photo-Fenton can be considered an alternative or complementary process to improve the performance of a biologic treatment and, subsequently, achieve legal limits on discharge into natural waters.

  11. Pretreatment of 2,4-dinitroanisole (DNAN) producing wastewater using a combined zero-valent iron (ZVI) reduction and Fenton oxidation process

    International Nuclear Information System (INIS)

    Shen, Jinyou; Ou, Changjin; Zhou, Zongyuan; Chen, Jun; Fang, Kexiong; Sun, Xiuyun; Li, Jiansheng; Zhou, Lin; Wang, Lianjun

    2013-01-01

    Highlights: • ZVI-Fenton process was conducted for DNAN producing wastewater pretreatment. • Transformation of nitro to amino group by ZVI overcomes the oxidative hindrance. • Subsequent Fenton process is efficient for the removal of aromatic compounds. • ABR-MBBR process is efficient for the polishing of ZVI-Fenton effluent. -- Abstract: A combined zero-valent iron (ZVI) reduction and Fenton oxidation process was tested for the pretreatment of 2,4-dinitroanisole (DNAN) producing wastewater. Operating conditions were optimized and overall performance of the combined process was evaluated. For ZVI process, almost complete reduction of nitroaromatic compounds was observed at empty bed contact time (EBCT) of 8 h. For Fenton process, the optimal pH, H 2 O 2 to Fe(II) molar ratio, H 2 O 2 dosage and hydraulic retention time (HRT) were found to be 3.0, 15, 0.216 mol/L and 5 h, respectively. After pretreatment by the combined ZVI-Fenton process under the optimal conditions, aromatic organic compound removal was as high as 77.2%, while the majority of COD remained to be further treated by sequent biological process. The combined anaerobic-aerobic process consisted of an anaerobic baffled reactor (ABR) and a moving-bed biofilm reactor (MBBR) was operated for 3 months, fed with ZVI-Fenton effluent. The results revealed that the coupled ZVI-Fenton-ABR-MBBR system was significantly efficient in terms of correcting the effluent's main parameters of relevance, mainly aromatic compounds concentration, COD concentration, color and acute toxicity. These results indicate that the combined ZVI-Fenton process offers bright prospects for the pretreatment of wastewater containing nitroaromatic compounds

  12. Comparison of Fenton, UV-Fenton and nano-Fe3O4 catalyzed UV-Fenton in degradation of phloroglucinol under neutral and alkaline conditions: Role of complexation of Fe3+ with hydroxyl group in phloroglucinol

    DEFF Research Database (Denmark)

    Wang, Yong; Lin, Xihuang; Shao, Zongze

    2017-01-01

    difference in TOC removal efficiency: about 90% for UV-Fenton, nearly 60% for Fenton and Hetero-Fenton. Increasing initial pH from 7.0 to 9.0, there was an obvious decline in the degradation rate. The average values of H2O2 utilization efficiency were 0.65 ± 0.01 for Fenton, 0.66 ± 0.09 for UV...

  13. Genotoxicity assessment of membrane concentrates of landfill leachate treated with Fenton reagent and UV-Fenton reagent using human hepatoma cell line

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Guifang [Department of Chemistry, Jinan University, Guangzhou 510632 (China); Lu, Gang [Key Laboratory of Water/Soil Toxic Pollutants Control and Bioremediation of Guangdong Higher Education Institutes, Department of Environmental Engineering, Jinan University, Guangzhou 510632 (China); Yin, Pinghe, E-mail: tyinph@jnu.edu.cn [Research Center of Analysis and Test, Jinan University, Guangzhou 510632 (China); Zhao, Ling, E-mail: zhaoling@jnu.edu.cn [Key Laboratory of Water/Soil Toxic Pollutants Control and Bioremediation of Guangdong Higher Education Institutes, Department of Environmental Engineering, Jinan University, Guangzhou 510632 (China); Jimmy Yu, Qiming [Griffith School of Engineering, Griffith University, Nathan Campus, Brisbane, Queensland 4111 (Australia)

    2016-04-15

    Highlights: • Membrane concentrates have a threat to human health and environment. • Untreated membrane concentrates induces cytotoxic and genotoxic to HepG2 cells. • Both methods were effective method for degradation of BPA and NP in concentrates. • Both methods were efficient in reducing genotoxic effects of concentrates. • UV-Fenton reagent had higher removal efficiency and provides toxicological safety. - Abstract: Membrane concentrates of landfill leachates contain organic and inorganic contaminants that could be highly toxic and carcinogenic. In this paper, the genotoxicity of membrane concentrates before and after Fenton and UV-Fenton reagent was assessed. The cytotoxicity and genotoxicity was determined by using the methods of methyltetrazolium (MTT), cytokinesis-block micronucleus (CBMN) and comet assay in human hepatoma cells. MTT assay showed a cytotoxicity of 75% after 24 h of exposure to the highest tested concentration of untreated concentrates, and no cytotoxocity for UV-Fenton and Fenton treated concentrates. Both CBMN and comet assays showed increased levels of genotoxicity in cells exposed to untreated concentrates, compared to those occurred in cells exposed to UV-Fenton and Fenton reagent treated concentrates. There was no significant difference between negative control and UV-Fenton treated concentrates for micronucleus and comet assay parameters. UV-Fenton and Fenton treatment, especially the former, were effective methods for degradation of bisphenol A and nonylphenol in concentrates. These findings showed UV-Fenton and Fenton reaction were effective methods for treatment of such complex concentrates, UV-Fenton reagent provided toxicological safety of the treated effluent, and the genotoxicity assays were found to be feasible tools for assessment of toxicity risks of complex concentrates.

  14. Genotoxicity assessment of membrane concentrates of landfill leachate treated with Fenton reagent and UV-Fenton reagent using human hepatoma cell line

    International Nuclear Information System (INIS)

    Wang, Guifang; Lu, Gang; Yin, Pinghe; Zhao, Ling; Jimmy Yu, Qiming

    2016-01-01

    Highlights: • Membrane concentrates have a threat to human health and environment. • Untreated membrane concentrates induces cytotoxic and genotoxic to HepG2 cells. • Both methods were effective method for degradation of BPA and NP in concentrates. • Both methods were efficient in reducing genotoxic effects of concentrates. • UV-Fenton reagent had higher removal efficiency and provides toxicological safety. - Abstract: Membrane concentrates of landfill leachates contain organic and inorganic contaminants that could be highly toxic and carcinogenic. In this paper, the genotoxicity of membrane concentrates before and after Fenton and UV-Fenton reagent was assessed. The cytotoxicity and genotoxicity was determined by using the methods of methyltetrazolium (MTT), cytokinesis-block micronucleus (CBMN) and comet assay in human hepatoma cells. MTT assay showed a cytotoxicity of 75% after 24 h of exposure to the highest tested concentration of untreated concentrates, and no cytotoxocity for UV-Fenton and Fenton treated concentrates. Both CBMN and comet assays showed increased levels of genotoxicity in cells exposed to untreated concentrates, compared to those occurred in cells exposed to UV-Fenton and Fenton reagent treated concentrates. There was no significant difference between negative control and UV-Fenton treated concentrates for micronucleus and comet assay parameters. UV-Fenton and Fenton treatment, especially the former, were effective methods for degradation of bisphenol A and nonylphenol in concentrates. These findings showed UV-Fenton and Fenton reaction were effective methods for treatment of such complex concentrates, UV-Fenton reagent provided toxicological safety of the treated effluent, and the genotoxicity assays were found to be feasible tools for assessment of toxicity risks of complex concentrates.

  15. Fenton and solar photo-Fenton processes for the removal of ...

    African Journals Online (AJOL)

    Fenton (H2O2/Fe2+/solar light) processes was investigated. A laboratory-scale reactor was designed to evaluate and select the optimal oxidation condition. The degradation rate is strongly dependent on pH, temperature, H2O2 dosing rate, ...

  16. Combined photo-Fenton-SBR process for antibiotic wastewater treatment

    International Nuclear Information System (INIS)

    Elmolla, Emad S.; Chaudhuri, Malay

    2011-01-01

    Highlights: · The work focused on hazardous wastewater (antibiotic wastewater) treatment. · Complete degradation of the antibiotics achieved by the treatment process. · The SBR performance was found to be very sensitive to BOD 5 /COD ratio below 0.40. · Combined photo-Fenton-SBR process is a feasible treatment process for the antibiotic wastewater. - Abstract: The study examined combined photo-Fenton-SBR treatment of an antibiotic wastewater containing amoxicillin and cloxacillin. Optimum H 2 O 2 /COD and H 2 O 2 /Fe 2+ molar ratio of the photo-Fenton pretreatment were observed to be 2.5 and 20, respectively. Complete degradation of the antibiotics occurred in one min. The sequencing batch reactor (SBR) was operated at different hydraulic retention times (HRTs) with the wastewater treated under different photo-Fenton operating conditions (H 2 O 2 /COD and H 2 O 2 /Fe 2+ molar ratio). The SBR performance was found to be very sensitive to BOD 5 /COD ratio of the photo-Fenton treated wastewater. Statistical analysis of the results indicated that it was possible to reduce the Fe 2+ dose and increase the irradiation time of the photo-Fenton pretreatment. The best operating conditions of the combined photo-Fenton-SBR treatment were observed to be H 2 O 2 /COD molar ratio 2, H 2 O 2 /Fe 2+ molar ratio 150, irradiation time 90 min and HRT of 12 h. Under the best operating conditions, 89% removal of sCOD with complete nitrification was achieved and the SBR effluent met the discharge standards.

  17. Comparison of Fenton and Fenton-like oxidation for the treatment of cosmetic wastewater.

    Science.gov (United States)

    Bautista, P; Casas, J A; Zazo, J A; Rodriguez, J J; Mohedano, A F

    2014-01-01

    The treatment of cosmetic wastewaters by Fenton (Fe²⁺/H₂O₂) and Fenton-like (Fe³⁺/H₂O₂) oxidation has been studied. From batch and continuous experiments it has been proved that both versions of the Fenton process lead to quite similar results in terms of chemical oxygen demand (COD) and total organic carbon reduction although the COD shows a slightly higher rate in the early stages of reaction. COD reductions of around 55% after 2 h reaction time and 75-80% with 4 h residence time were reached in batch and continuous experiments, respectively, conducted at pH around 3, ambient temperature (20 °C), with 200 mg/L of Fe dose and an initial H₂O₂/COD weight ratio corresponding to the theoretical stoichiometric value. Achieving the locally allowable limit of COD for industrial wastewater discharge into the municipal sewer system takes no more than 30 min reaction time under those conditions by both Fenton systems. However, the Fenton-like process, where iron is fed as Fe(3+), would be preferable for industrial applications since the ferric sludge resulting upon final neutralization of the effluent can be recycled to the process. A second-order kinetic equation with respect to COD fitted fairly well the experimental results at different temperatures, thus providing a simple practical tool for design purposes.

  18. Heterogeneous Fenton-like discoloration of methyl orange using Fe3O4/MWCNTs as catalyst: kinetics and Fenton-like mechanism

    Science.gov (United States)

    Xu, Huan-Yan; Wang, Yuan; Shi, Tian-Nuo; Zhao, Hang; Tan, Qu; Zhao, Bo-Chao; He, Xiu-Lan; Qi, Shu-Yan

    2018-03-01

    The kinetics and Fenton-like mechanism are two challenging tasks for heterogeneous Fenton-like catalytic oxidation of organic pollutants. In this study, three kinetic models were used for the kinetic studies of Fe3O4/MWCNTs-H2O2 Fenton-like reaction for MO degradation. The results indicated that this reaction followed the first-order kinetic model. The relationship of reaction rate constant and temperature followed the Arrhenius equation. The activation energy and frequency factor of this system were calculated as 8.2 kJ·mol-1 and 2.72 s-1, respectively. The quantifications of Fe ions dissolution and •OH radicals generation confirmed that the homogeneous and heterogeneous catalyses were involved in Fe3O4/MWCNTs-H2O2 Fenton-like reaction. The reaction rate constant was closely related with Fe ions dissolution and •OH radicals generation. Fe3O4/MWCNTs nanocomposites had typical ferromagnetic property and could be easily separated from solution by an external magnet after being used. Furthermore, Fe3O4/MWCNTs nanocomposites exhibited good stability and recyclability. Finally, the Fenton-like mechanisms on homogeneous and heterogeneous catalyses were described.

  19. Tertiary treatment of pulp mill wastewater by solar photo-Fenton

    Energy Technology Data Exchange (ETDEWEB)

    Lucas, Marco S., E-mail: mlucas@utad.pt [Centro de Quimica de Vila Real, Universidade de Tras-os-Montes e Alto Douro, Apartado 1013, 5001-801 Vila Real (Portugal); Peres, Jose A.; Amor, Carlos [Centro de Quimica de Vila Real, Universidade de Tras-os-Montes e Alto Douro, Apartado 1013, 5001-801 Vila Real (Portugal); Prieto-Rodriguez, Lucia; Maldonado, Manuel I.; Malato, Sixto [Plataforma Solar de Almeria (CIEMAT), Carretera de Senes, Km 4, 04200, Tabernas, Almeria (Spain)

    2012-07-30

    Highlights: Black-Right-Pointing-Pointer We firstly report a real pulp mill wastewater treatment by solar photo-Fenton in a CPC reactor. Fenton reagent experiments were tested firstly. Black-Right-Pointing-Pointer Solar photo-Fenton presents excellent ability to treat the pulp mill wastewater. Black-Right-Pointing-Pointer Experimental conditions were optimised. Black-Right-Pointing-Pointer Biodegradability and toxicity tests (respirometry assays and BOD{sub 5}/COD ratio) were performed during the wastewater treatment. Black-Right-Pointing-Pointer A way to reduce the economic and environmental impact was evaluated. - Abstract: This work reports on pulp mill wastewater (PMW) tertiary treatment by Fenton (Fe{sup 2+}/H{sub 2}O{sub 2}) and solar photo-Fenton (Fe{sup 2+}/H{sub 2}O{sub 2}/UV) processes in a pilot plant based on compound parabolic collectors (CPCs). Solar photo-Fenton reaction is much more efficient than the respective dark reaction under identical experimental conditions. It leads to DOC mineralisation, COD and total polyphenols (TP) removal higher than 90%. The solar photo-Fenton experiment with 5 mg Fe L{sup -1} reaches 90% of DOC mineralisation with 31 kJ L{sup -1} of UV energy and 50 mM of H{sub 2}O{sub 2}. The initial non-biodegradability of PMW, as shown by respirometry assays and BOD{sub 5}/COD ratio, can be changed after a solar photo-Fenton treatment. Experiments with 20 and 50 mg Fe L{sup -1} revealed that solar photo-Fenton can reach the same DOC degradation (90%), however, consuming less H{sub 2}O{sub 2} and time. Diluting the initial organic load to 50% also diminishes the dosage of H{sub 2}O{sub 2} and the necessary reaction time to achieve high DOC removals. Accordingly, solar photo-Fenton can be considered an alternative or complementary process to improve the performance of a biologic treatment and, subsequently, achieve legal limits on discharge into natural waters.

  20. Roles of free radicals in NO oxidation by Fenton system and the enhancement on NO oxidation and H2O2 utilization efficiency.

    Science.gov (United States)

    Zhao, Haiqian; Dong, Ming; Wang, Zhonghua; Wang, Huaiyuan; Qi, Hanbing

    2018-06-20

    Low H 2 O 2 utilization efficiency is the main problem when Fenton system was used to oxidize NO in flue gas. To understand the behavior of the free radicals during NO oxidation process in Fenton system is crucial to solving this problem. The oxidation capacity of ·OH and HO 2 · on NO in Fenton system was compared and the useless consumption path of ·OH and HO 2 · that caused the low utilization efficiency of H 2 O 2 were studied. A method to enhance the oxidation ability and H 2 O 2 utilization efficiency by adding reducing additives in Fenton system was proposed. The results showed that both of ·OH and HO 2 · were active substances that oxidize NO. However, the oxidation ability of ·OH radicals was stronger. The vast majority of ·OH and HO 2 · was consumed by rapid reaction ·OH+HO 2 ·→H 2 O+O 2 , which was the primary reason for the low utilization efficiency of H 2 O 2 in Fenton system. Hydroxylamine hydrochloride and ascorbic acid could accelerate the conversion of Fe 3+ to Fe 2+ , thereby increase the generation rate of ·OH and decrease the generation rate of HO 2 ·. As a result, the oxidation ability and H 2 O 2 utilization efficiency were enhanced.

  1. Degradação de poluentes emergentes por processos Fenton e foto-Fenton

    Directory of Open Access Journals (Sweden)

    Marco A. Benedetti Durigan

    2012-01-01

    Full Text Available A continuous photochemical treatment system was developed for aiming the treatment of aqueous solutions containing relevant micro-pollutants (microcystin-LR, sulfamethoxazole and 17-b estradiol. The continuous photo-Fenton process provided high degradation efficiency. However, contact time between samples and the irradiated region is short relative to total treatment time, indicating that observed changes are predominantly due to the Fenton process. Higher degradation efficiency was observed in systems operated using two treatment cycles, the first involving a batch Fenton process and the second a continuous photo-Fenton treatment.

  2. Heterogeneous activation of H_2O_2 by defect-engineered TiO_2_−_x single crystals for refractory pollutants degradation: A Fenton-like mechanism

    International Nuclear Information System (INIS)

    Zhang, Ai-Yong; Lin, Tan; He, Yuan-Yi; Mou, Yu-Xuan

    2016-01-01

    Highlights: • Facet- and defect-engineered TiO_2 is proposed for water treatment as Fenton-like catalyst. • The =Ti(III) center serves as lattice shuttle for electron transfer in H_2O_2 activation. • TiO_2 is promising due to low cost, high abundance, no toxicity and stable performance. - Abstract: The heterogeneous catalyst plays a key role in Fenton-like reaction for advanced oxidation of refractory pollutants in water treatment. Titanium dioxide (TiO_2) is a typical semiconductor with high industrial importance due to its earth abundance, low cost and no toxicity. In this work, it is found that TiO_2 can heterogeneously activate hydrogen peroxide (H_2O_2, E° = 1.78 eV), a common chemical oxidant, to efficiently generate highly-powerful hydroxyl radical, ·OH (E"0 = 2.80 eV), for advanced water treatment, when its crystal shape, exposed facet and oxygen-stoichiometry are finely tuned. The defect-engineered TiO_2 single crystals exposed by high-energy {0 0 1} facets exhibited an excellent Fenton-like activity and stability for degrading typical refractory organic pollutants such as methyl orange and p-nitrophenol. Its defect-centered Fenton-like superiority is mainly attributed to the crystal oxygen-vacancy, single-crystalline structure and exposed polar {0 0 1} facet. Our findings could provide new chance to utilize TiO_2 for Fenton-like technology, and develop novel heterogeneous catalyst for advanced water treatment.

  3. Combined photo-Fenton-SBR process for antibiotic wastewater treatment

    Energy Technology Data Exchange (ETDEWEB)

    Elmolla, Emad S., E-mail: em_civil@yahoo.com [Department of Civil Engineering, Faculty of Engineering, Al-Azhar University, Cairo (Egypt); Chaudhuri, Malay [Department of Civil Engineering, Universiti Teknologi PETRONAS, Bandar Seri Iskandar, 31750 Tronoh, Perak (Malaysia)

    2011-09-15

    Highlights: {center_dot} The work focused on hazardous wastewater (antibiotic wastewater) treatment. {center_dot} Complete degradation of the antibiotics achieved by the treatment process. {center_dot} The SBR performance was found to be very sensitive to BOD{sub 5}/COD ratio below 0.40. {center_dot} Combined photo-Fenton-SBR process is a feasible treatment process for the antibiotic wastewater. - Abstract: The study examined combined photo-Fenton-SBR treatment of an antibiotic wastewater containing amoxicillin and cloxacillin. Optimum H{sub 2}O{sub 2}/COD and H{sub 2}O{sub 2}/Fe{sup 2+} molar ratio of the photo-Fenton pretreatment were observed to be 2.5 and 20, respectively. Complete degradation of the antibiotics occurred in one min. The sequencing batch reactor (SBR) was operated at different hydraulic retention times (HRTs) with the wastewater treated under different photo-Fenton operating conditions (H{sub 2}O{sub 2}/COD and H{sub 2}O{sub 2}/Fe{sup 2+} molar ratio). The SBR performance was found to be very sensitive to BOD{sub 5}/COD ratio of the photo-Fenton treated wastewater. Statistical analysis of the results indicated that it was possible to reduce the Fe{sup 2+} dose and increase the irradiation time of the photo-Fenton pretreatment. The best operating conditions of the combined photo-Fenton-SBR treatment were observed to be H{sub 2}O{sub 2}/COD molar ratio 2, H{sub 2}O{sub 2}/Fe{sup 2+} molar ratio 150, irradiation time 90 min and HRT of 12 h. Under the best operating conditions, 89% removal of sCOD with complete nitrification was achieved and the SBR effluent met the discharge standards.

  4. Kaolinite adsorption-regeneration system for dyestuff treatment by Fenton based processes.

    Science.gov (United States)

    Rosales, Emilio; Anasie, Delia; Pazos, Marta; Lazar, Iuliana; Sanromán, M Angeles

    2018-05-01

    The regeneration and reuse of adsorbents is a subject of interest nowadays in order to reduce the pollution and the wastes generated in the adsorption wastewater treatment. In this work, the regeneration of the spent kaolinite by different advanced oxidation processes (Fenton, electro-Fenton and electrokinetic-Fenton) was evaluated. Initially, it was confirmed the ability of a low cost clayey material, kaolinite, for the adsorption of model dye such as Rhodamine B showing Freundlich isotherm fitting. Then, the regeneration and consequent degradation of the pollutant in the adsorbent by Fenton based processes was carried out. The role of different parameters affecting the regeneration process (H 2 O 2 :Fe 2+ ratio, liquid:solid ratio) were evaluated. Working at 100:1 H 2 O 2 :Fe 2+ ratio and 30min near complete dye removal (around 97%) from kaolinite was obtained by Fenton treatment. After that, a two-stage treatment for adsorption-regeneration was evaluated during five treatment cycles demonstrating its viability for regeneration of the adsorbent through dye degradation. Based on the successful application of Fenton technique, the improvement of the treatment by electro-Fenton and electrokinetic-Fenton were studied for different solid:liquid ratios achieving satisfactory regeneration values. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Oxidação em processos Fenton e Foto-Fenton em efluentes de curtumes - DOI: 10.4025/actascitechnol.v25i1.2254

    Directory of Open Access Journals (Sweden)

    Tirzhá Lins Porto Dantas

    2003-04-01

    Full Text Available Os processos Fenton e Foto-fenton são alternativas atraentes no tratamento de efluentes, especialmente aplicados àqueles contendo compostos recalcitrantes. Neste trabalho foi avaliada a remoção de DQO e amônia durante o tratamento de efluentes de curtumes pelos processos Fenton e Foto-Fenton. A cinética de degradação foi dividida em dois estágios, sendo um processo inicial rápido, no qual 70% da DQO inicial é removida; seguido por uma etapa lenta que acontece em até 4 horas de reação, alcançando cerca de 90% de remoção da DQO inicial. Diferentes proporções mássicas Fé2+/H2O2 foram testadas e os resultados mostraram que a eficiência dos processos Fenton e Foto-Fenton aumenta de 65 até 90% à medida que a produção de radicais livres hidroxil aumenta. Nenhuma diferença apreciável na degradação de nitrogênio amoniacal foi observada entre os processos Fenton e Foto-Fenton, mesmo após a coagulação. A remoção de amônia foi atribuída à oxidação de compostos orgânicos, formando N2 e íons nitrato. A toxicidade do efluente tratado diminuiu até a dosagem de 9g/L de H2O2 e aumentou para maiores dosagens, devido ao residual peróxido de hidrogênio ou a formação de produtos oxidados mais tóxicos.

  6. Analgesic effect of GT-0198, a structurally novel glycine transporter 2 inhibitor, in a mouse model of neuropathic pain

    Directory of Open Access Journals (Sweden)

    Yu Omori

    2015-03-01

    Full Text Available This study was conducted to identify the characteristic pharmacological features of GT-0198 that is phenoxymethylbenzamide derivatives. GT-0198 inhibited the function of glycine transporter 2 (GlyT2 in human GlyT2-expressing HEK293 cells and did not bind various major transporters or receptors of neurotransmitters in a competitive manner. Thus, GT-0198 is considered to be a comparatively selective GlyT2 inhibitor. Intravenous, oral, and intrathecal injections of GT-0198 decreased the pain-related response in a model of neuropathic pain with partial sciatic nerve ligation. This result suggests that GT-0198 has an analgesic effect. The analgesic effect of GT-0198 was abolished by the intrathecal injection of strychnine, a glycine receptor antagonist. Therefore, GT-0198 is considered to exhibit its analgesic effect via the activation of a glycine receptor by glycine following presynaptic GlyT2 inhibition in the spinal cord. In summary, GT-0198 is a structurally novel GlyT2 inhibitor bearing a phenoxymethylbenzamide moiety with in vivo efficacy in behavioral models of neuropathic pain.

  7. Alternate switching between MFC and MEC for H2O2 synthesis and residual removal in Bioelectro-Fenton system

    DEFF Research Database (Denmark)

    Zhang, Yifeng; Angelidaki, Irini

    2016-01-01

    Sustainable H2O2 supply and elimination of residual H2O2 are two key challenges to the Fenton processes treating recalcitrant contaminants. In this study, an innovative Bioelectro-Fenton system capable of alternate switching between microbial electrolysis cell (MEC) and microbial fuel cell (MFC......) mode of operation was developed to meet the challenges. In the MEC mode, H2O2 was electrochemically produced which reacts with Fenton’s reagent (Fe II) to form hydroxyradical. The residual H2O2 (unused H2O2) is removed as electron acceptor by switching the system to MFC mode. Complete decolorization...

  8. Degradation of p-nitrophenol using acoustic cavitation and Fenton chemistry

    International Nuclear Information System (INIS)

    Pradhan, Amey A.; Gogate, Parag R.

    2010-01-01

    Due to increasing human requirements, newer chemical species are being observed in the effluent streams with higher loadings such that efficacy of conventional treatment techniques is decreased and a combination of advanced oxidation processes is implemented for enhanced treatment ability and better energy efficiency. In the present work, the efficacy of combination of sonochemistry and Fenton chemistry has been investigated for wastewater treatment considering p-nitrophenol as model pollutant at pilot scale operation. Degradation of p-nitrophenol has been investigated under various operating conditions based on the use of ultrasound, Fenton process, ultrasound and H 2 O 2 , ultrasound and Fe, ultrasound and FeSO 4 , ultrasound and conventional Fenton process and ultrasound and advanced Fenton process. Two different initial concentrations of 0.5 and 1% of p-nitrophenol have been used for the experiments. In conventional Fenton and advanced Fenton process, two loadings of FeSO 4 and Fe powder 0.5 and 1 g/l and three ratios of FeSO 4 :H 2 O 2 and Fe:H 2 O 2 (1:5, 1:7.5 and 1:10) were investigated respectively. In all the systems investigated, maximum extent of degradation (66.4%) was observed for 0.5% p-nitrophenol concentration (w/v) using a combination of ultrasound and advanced Fenton process. The novelty of the work is in terms of investigating the efficacies of combined advanced oxidation processes based on the use of cavitation and Fenton chemistry at pilot scale operation and tries to establish the missing design related information for large scale operation of wastewater treatment.

  9. Degradation alternatives for a commercial fungicide in water: biological, photo-Fenton, and coupled biological photo-Fenton processes.

    Science.gov (United States)

    López-Loveira, Elsa; Ariganello, Federico; Medina, María Sara; Centrón, Daniela; Candal, Roberto; Curutchet, Gustavo

    2017-11-01

    Imazalil (IMZ) is a widely used fungicide for the post-harvest treatment of citrus, classified as "likely to be carcinogenic in humans" for EPA, that can be only partially removed by conventional biological treatment. Consequently, specific or combined processes should be applied to prevent its release to the environment. Biological treatment with adapted microorganism consortium, photo-Fenton, and coupled biological photo-Fenton processes were tested as alternatives for the purification of water containing high concentration of the fungicide and the coadjutants present in the commercial formulation. IMZ-resistant consortium with the capacity to degrade IMZ in the presence of a C-rich co-substrate was isolated from sludge coming from a fruit packaging company wastewater treatment plant. This consortium was adapted to resist and degrade the organics present in photo-Fenton-oxidized IMZ water solution. Bacteria colonies from the consortia were isolated and identified. The effect of H 2 O 2 initial concentration and dosage on IMZ degradation rate, average oxidation state (AOS), organic acid concentration, oxidation, and mineralization percentage after photo-Fenton process was determined. The application of biological treatment to the oxidized solutions notably decreased the total organic carbon (TOC) in solution. The effect of the oxidation degree, limited by H 2 O 2 concentration and dosage, on the percentage of mineralization obtained after the biological treatment was determined and explained in terms of changes in AOS. The concentration of H 2 O 2 necessary to eliminate IMZ by photo-Fenton and to reduce TOC and chemical oxygen demand (COD) by biological treatment, in order to allow the release of the effluents to rivers with different flows, was estimated.

  10. Removal of refractory organics in nanofiltration concentrates of municipal solid waste leachate treatment plants by combined Fenton oxidative-coagulation with photo--Fenton processes.

    Science.gov (United States)

    Li, Jiuyi; Zhao, Lei; Qin, Lele; Tian, Xiujun; Wang, Aimin; Zhou, Yanmei; Meng, Liao; Chen, Yong

    2016-03-01

    Removal of the refractory organic matters in leachate brines generated from nanofiltration unit in two full-scale municipal solid waste landfill leachate treatment plants was investigated by Fenton oxidative-coagulation and ultraviolet photo - Fenton processes in this study. Fenton oxidative-coagulation was performed under the condition of an initial pH of 5.0 and low H2O2/Fe(2+) ratios. After precipitate separation, the remaining organic constituents were further oxidized by photo - Fenton process. For both leachate brines with varying pollution strength, more than 90% COD and TOC reductions were achieved at H2O2/Fe(2+) dosages of 35 mM/8 mM and 90 mM/10 mM, respectively. The effluent COD ranged 120-160 mg/L under the optimal operating conditions, and the biodegradability was increased significantly. Fenton oxidative-coagulation was demonstrated to contribute nearly 70% overall removal of organic matters. In the combined processes, the efficiency of hydrogen peroxide varied from 216 to 228%, which may significantly reduce the operating cost of conventional Fenton method. Six phthalic acid esters and thirteen polycyclic aromatic hydrocarbons were found in leachate brines, and, on the average, around 80% phthalic acid esters and 90% polycyclic aromatic hydrocarbons were removed by the combined treatments. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Striking a Balance between Program Requirements and GT Principles: Writing a compromised GT proposal

    Directory of Open Access Journals (Sweden)

    Sherry L. Xie, Ph.D. Candidate

    2009-06-01

    Full Text Available Glaser’s term “compromised GT proposal” (2001, p.114 refers to the type of Grounded Theory (GT proposal that is written in order to conform to the requirements of a standardized qualitative research proposal. A GT proposal needs only to supply information on the area of interest, the data source and a statement of method to the effect that the researcher begin to collect, code and analyse the data and let the theory emerge. Thus, the proposal may only occupy “a page or two” (Glaser, 2001, p. 111. Whilst being consistent with the methodology, a GT proposal sometimes has to give way to the format specified by a PhD program or committee even though the format was not defined for a GT proposal and in some areas, conflicts with GT principles; for example, the format may require a literature review. This short paper reports on my experience of writing a compromised GT proposal as a first-time GT researcher. It describes how both Glaser’s advice on writing compromised GT research proposals and the characteristics of the substantive area of the proposed research were used to satisfy program requirements while still maintaining GT fundamentals.

  12. On-surface Fenton and Fenton-like reactions appraised by paper spray ionization mass spectrometry.

    Science.gov (United States)

    Resende, S F; Oliveira, B S; Augusti, R

    2018-06-21

    On-surface degradation of sildenafil (an adequate substrate as it contains assorted functional groups in its structure) promoted by the Fenton (Fe 2+ / H 2 O 2 ) and Fenton-like (M n+ / H 2 O 2 ; M n+ = Fe 3+ , Co 2+ , Cu 2+ , Mn 2+ ) systems was investigated by using paper spray ionization mass spectrometry (PS-MS). The performance of each system was compared by measuring the ratio between the relative intensities of the ions of m/z 475 (protonated sildenafil) and m/z 235 (protonated lidocaine, used as a convenient internal standard and added to the paper just before the PS-MS analyzes). The results indicated the following order in the rates of such reactions: Fe 2+ /H 2 O 2 > H 2 O 2 > Cu 2+ /H 2 O 2 > M n+ / H 2 O 2 (M n+ = Fe 3+ , Co 2+ , Mn 2+ ) ~ M n+ (M n+ = Fe 2+ , Fe 3+ , Co 2+ , Cu 2+ , Mn 2 . The superior capability of Fe 2+ /H 2 O 2 in causing the degradation of sildenafil indicates that Fe 2+ efficiently decomposes H 2 O 2 to yield hydroxyl radicals, quite reactive species that cause the substrate oxidation. The results also indicate that H 2 O 2 can spontaneously decompose likely to yield hydroxyl radicals, although in a much smaller extension than the Fenton system. This effect, however, is strongly inhibited by the presence of the other cations, i. e. Fe 3+ , Co 2+ , Cu 2+ and Mn 2+ . A unique oxidation by-product was detected in the reaction between Fe 2+ /H 2 O 2 with sildenafil and a possible structure for it was proposed based on the MS/MS data. The on-surface reaction of other substrates (trimethoprim and tamoxifen) with the Fenton system was also investigated. In conclusion, PS-MS shown to be a convenient platform to promptly monitor on-surface oxidation reactions. This article is protected by copyright. All rights reserved.

  13. Drinking water and biofilm disinfection by Fenton-like reaction.

    Science.gov (United States)

    Gosselin, F; Madeira, L M; Juhna, T; Block, J C

    2013-10-01

    A Fenton-like disinfection process was conducted with Fenton's reagent (H2O2) at pH 3 or 5 on autochthonous drinking water biofilms grown on corroded or non-corroded pipe material. The biofilm disinfection by Fenton-like oxidation was limited by the low content of iron and copper in the biomass grown on non-corroded plumbing. It was slightly improved by spiking the distribution system with some additional iron source (soluble iron II or ferrihydrite particles appeared as interesting candidates). However successful in situ disinfection of biofilms was only achieved in fully corroded cast iron pipes using H2O2 and adjusting the pH to 5. These new results provide additional support for the use of Fenton's processes for cleaning drinking water distribution systems contaminated with biological agents or organics. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. ESTUDO MECANÍSTICO DAS REAÇÕES FENTON E CUPRO-FENTON POR ANÁLISE VOLTAMÉTRICA IN SITU

    Directory of Open Access Journals (Sweden)

    Leidi C. Friedrich

    Full Text Available Although the classical Fenton process exhibits a high initial rate of the organic compounds degradation, this process is not complete due to the formation of refractory compounds which resist the attack of the hydroxyl radicals. In the presence of Cu(II, the degradation is slower, but results in a greater reduction of TOC (total organic carbon measurements of net mineralization at the end of the reaction (t=120min. The addition of Cu(II ions to classical Fenton reaction conditions (Fe(II plus H2O2 at pH 3 is shown to accelerate the degradation of organic compounds. This synergic effect causes an approximately 15% additional reduction of the TOC. Voltammetric studies confirm the catalytic role of catechol in the presence of Fe(III/Fe(II and Cu(II/Cu(I. Addition of aliphatic acids to the reaction medium, did not interfere with the cupro-Fenton reaction, but had an inhibitory effect on the classical Fenton reaction, consistent with the following order of interaction with the ion Fe(III: Oxalic Acid (OA >> Formic Acid (FA ~ Acetic acid (AA.

  15. Main: GT1CONSENSUS [PLACE

    Lifescience Database Archive (English)

    Full Text Available m of GT-1 may be achieved through direct interaction between TFIIA and GT-1; Binding of GT-1-like factors to the PR-1a promoter influ...ences the level of SA-inducible gene expression; GT-1; light; TATA; TFIIA; TBP; HR;

  16. A comparison of the Actigraph GT1M and GT3X accelerometers under standardized and free-living conditions

    International Nuclear Information System (INIS)

    Kaminsky, Leonard A; Ozemek, Cemal

    2012-01-01

    Prior to 2008, data collection from Actigraph accelerometers was only possible in the uniaxial mode. In 2009, Actigraph released the GT3X, which allows triaxial data collection. The purpose of this study was to determine if data collected by the GT3X in the uniaxial mode are comparable to its predecessor, the GT1M, under both standardized and free-living conditions. Thirty-four subjects (17 women and 17 men) provided complete data for this study. Subjects wore the accelerometers (one GT1M and one GT3X) on their waistband in line with the right and left anterior axillary lines. Each subject walked on a treadmill at speeds of 2.4, 3.2, 4.0, 4.8, 5.6 and 6.4 km h −1 for 5 min each, and then continued to wear both accelerometers for all waking hours for three consecutive days. Mean steady-state activity counts min –1 for both accelerometers were not statistically different for the standardized treadmill walking speeds and for mean minutes/day and activity counts/day for intensity classifications under the free-living condition. Based on comparisons made from both standardized walking speeds and free-living conditions, it is reasonable to compare data derived from either the GT1M or GT3X when collected in the uniaxial mode. (paper)

  17. Genotoxicity assessment of membrane concentrates of landfill leachate treated with Fenton reagent and UV-Fenton reagent using human hepatoma cell line.

    Science.gov (United States)

    Wang, Guifang; Lu, Gang; Yin, Pinghe; Zhao, Ling; Yu, Qiming Jimmy

    2016-04-15

    Membrane concentrates of landfill leachates contain organic and inorganic contaminants that could be highly toxic and carcinogenic. In this paper, the genotoxicity of membrane concentrates before and after Fenton and UV-Fenton reagent was assessed. The cytotoxicity and genotoxicity was determined by using the methods of methyltetrazolium (MTT), cytokinesis-block micronucleus (CBMN) and comet assay in human hepatoma cells. MTT assay showed a cytotoxicity of 75% after 24h of exposure to the highest tested concentration of untreated concentrates, and no cytotoxocity for UV-Fenton and Fenton treated concentrates. Both CBMN and comet assays showed increased levels of genotoxicity in cells exposed to untreated concentrates, compared to those occurred in cells exposed to UV-Fenton and Fenton reagent treated concentrates. There was no significant difference between negative control and UV-Fenton treated concentrates for micronucleus and comet assay parameters. UV-Fenton and Fenton treatment, especially the former, were effective methods for degradation of bisphenol A and nonylphenol in concentrates. These findings showed UV-Fenton and Fenton reaction were effective methods for treatment of such complex concentrates, UV-Fenton reagent provided toxicological safety of the treated effluent, and the genotoxicity assays were found to be feasible tools for assessment of toxicity risks of complex concentrates. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Interfacial mechanisms of heterogeneous Fenton reactions catalyzed by iron-based materials: A review.

    Science.gov (United States)

    He, Jie; Yang, Xiaofang; Men, Bin; Wang, Dongsheng

    2016-01-01

    The heterogeneous Fenton reaction can generate highly reactive hydroxyl radicals (OH) from reactions between recyclable solid catalysts and H2O2 at acidic or even circumneutral pH. Hence, it can effectively oxidize refractory organics in water or soils and has become a promising environmentally friendly treatment technology. Due to the complex reaction system, the mechanism behind heterogeneous Fenton reactions remains unresolved but fascinating, and is crucial for understanding Fenton chemistry and the development and application of efficient heterogeneous Fenton technologies. Iron-based materials usually possess high catalytic activity, low cost, negligible toxicity and easy recovery, and are a superior type of heterogeneous Fenton catalysts. Therefore, this article reviews the fundamental but important interfacial mechanisms of heterogeneous Fenton reactions catalyzed by iron-based materials. OH, hydroperoxyl radicals/superoxide anions (HO2/O2(-)) and high-valent iron are the three main types of reactive oxygen species (ROS), with different oxidation reactivity and selectivity. Based on the mechanisms of ROS generation, the interfacial mechanisms of heterogeneous Fenton systems can be classified as the homogeneous Fenton mechanism induced by surface-leached iron, the heterogeneous catalysis mechanism, and the heterogeneous reaction-induced homogeneous mechanism. Different heterogeneous Fenton systems catalyzed by characteristic iron-based materials are comprehensively reviewed. Finally, related future research directions are also suggested. Copyright © 2015. Published by Elsevier B.V.

  19. Heterogeneous activation of H{sub 2}O{sub 2} by defect-engineered TiO{sub 2−x} single crystals for refractory pollutants degradation: A Fenton-like mechanism

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Ai-Yong, E-mail: ayzhang@hfut.edu.cn; Lin, Tan; He, Yuan-Yi; Mou, Yu-Xuan

    2016-07-05

    Highlights: • Facet- and defect-engineered TiO{sub 2} is proposed for water treatment as Fenton-like catalyst. • The =Ti(III) center serves as lattice shuttle for electron transfer in H{sub 2}O{sub 2} activation. • TiO{sub 2} is promising due to low cost, high abundance, no toxicity and stable performance. - Abstract: The heterogeneous catalyst plays a key role in Fenton-like reaction for advanced oxidation of refractory pollutants in water treatment. Titanium dioxide (TiO{sub 2}) is a typical semiconductor with high industrial importance due to its earth abundance, low cost and no toxicity. In this work, it is found that TiO{sub 2} can heterogeneously activate hydrogen peroxide (H{sub 2}O{sub 2}, E° = 1.78 eV), a common chemical oxidant, to efficiently generate highly-powerful hydroxyl radical, ·OH (E{sup 0} = 2.80 eV), for advanced water treatment, when its crystal shape, exposed facet and oxygen-stoichiometry are finely tuned. The defect-engineered TiO{sub 2} single crystals exposed by high-energy {0 0 1} facets exhibited an excellent Fenton-like activity and stability for degrading typical refractory organic pollutants such as methyl orange and p-nitrophenol. Its defect-centered Fenton-like superiority is mainly attributed to the crystal oxygen-vacancy, single-crystalline structure and exposed polar {0 0 1} facet. Our findings could provide new chance to utilize TiO{sub 2} for Fenton-like technology, and develop novel heterogeneous catalyst for advanced water treatment.

  20. Treatment of hazardous waste landfill leachate using Fenton oxidation process

    Science.gov (United States)

    Singa, Pradeep Kumar; Hasnain Isa, Mohamed; Ho, Yeek-Chia; Lim, Jun-Wei

    2018-03-01

    The efficiency of Fenton's oxidation was assessed in this study for hazardous waste landfill leachate treatment. The two major reagents, which are generally employed in Fenton's process are H2O2 as oxidizing agent and Fe2+ as catalyst. Batch experiments were conducted to determine the effect of experimental conditions viz., reaction time, molar ratio, and Fenton reagent dosages, which are significant parameters that influence the degradation efficiencies of Fenton process were examined. It was found that under the favorable experimental conditions, maximum COD removal was 56.49%. The optimum experimental conditions were pH=3, H2O2/Fe2+ molar ratio = 3 and reaction time = 150 minutes. The optimal amount of hydrogen peroxide and iron were 0.12 mol/L and 0.04 mol/L respectively. High dosages of H2O2 and iron resulted in scavenging effects on OH• radicals and lowered degradation efficiency of organic compounds in the hazardous waste landfill leachate.

  1. Parameters and a magnitude moment relationship from small earthquakes observed during hydraulic fracturing experiments in crystalline rocks

    Energy Technology Data Exchange (ETDEWEB)

    Pearson, C.

    1982-04-01

    Using source parameters estimated from seismic spectra and magnitudes estimated from coda lengths, we demonstrate that the log-linear relationship between moment and magnitude holds for events with magnitudes as low as -6. Using, as a data set, events induced by hydraulic fracturing experiments at the Fenton Hill, New Mexico, Hot Dry Rock (HDR) geothermal site, we find that the relationship between magnitude M and seismic moment (Mo) is log (Mo) = 17.27+0.77 M Moreover, the linear relationship between seismic moment and source radius (r) holds for the Fenton Hill microearthquakes. Analyses of the Fenton Hill data yield the following relationship. log (r) = 2.28+0.19 log (Mo)

  2. Decolorization of Mordant red 73 azo dye in water using H2O2/UV and photo-Fenton treatment.

    Science.gov (United States)

    Elmorsi, Taha M; Riyad, Yasser M; Mohamed, Zeinhom H; Abd El Bary, Hassan M H

    2010-02-15

    Decolorization of the Mordant red 73 (MR73) azo dye in water was investigated in laboratory-scale experiments using UV/H(2)O(2) and photo-Fenton treatments. Photodegradation experiments were carried out in a stirred batch photoreactor equipped with a low-pressure mercury lamp as UV source at 254 nm. The effect of operating parameters such as pH, [H(2)O(2)](,) [dye] and the presence of inorganic salts (NaNO(3), NaCl and Na(2)CO(3)) were also investigated. The results indicated that complete dye decolorization was obtained in less than 60 min under optimum conditions. Furthermore, results showed that dye degradation was dependent upon pH, [H(2)O(2)] and initial dye concentration. The presence of chloride ion led to large decreases in the photodegradation rate of MR73 while both nitrate and carbonate ions have a slight effect. The photo-Fenton treatment, in the presence of Fe powder as a source of Fe(2+) ions, was highly efficient and resulted in 99% decolorization of the dye in 15 min. Mineralization of MR73 dye was investigated by determining chemical oxygen demand (COD). In a 3h photoperiod "65%" of the dye was mineralized by the H(2)O(2)/UV process, while the photo-Fenton treatment was more efficient producing 85% mineralization over the same 3-h period.

  3. Hepatitis A Virus Disinfection in Water by Solar Photo-Fenton Systems.

    Science.gov (United States)

    Polo, David; García-Fernández, Irene; Fernández-Ibañez, Pilar; Romalde, Jesús L

    2018-06-01

    This study evaluates and compares the effectiveness of solar photo-Fenton systems for the inactivation of hepatitis A virus (HAV) in water. The effect of solar irradiance, dark- Fenton reaction and three different reactant concentrations (2.5/5, 5/10 and 10/20 mg/L of Fe 2+ /H 2 O 2 ) on the photo-Fenton process were tested in glass bottle reactors (200 mL) during 6 h under natural sunlight. Disinfection kinetics were determined both by RT-qPCR and infectivity assays. Mean water temperatures ranged from 25 to 27.3 °C, with a maximum local noon UV irradiances of 22.36 W/m 2 . Photo-Fenton systems yielded increased viral reduction rates in comparison with the isolated effect under the Fenton reaction in darkness (negligible viral reduction) or the solar radiation (0.25 Log of RNA reduction). With the highest concentration employed (10-20 mg/L Fe 2+ -H 2 O 2 ), an average RNA reduction rate of ~ 1.8 Log (initial concentration of 10 5 pfu/mL) and a reduction of 80% in the infectivity capacity were reached. Results showed a strong synergistic effect between Fe 2+ /H 2 O 2 and sunlight, demonstrating that significant disinfection rates of HAV under photo-Fenton systems may occur with relatively higher efficiency at middle environmental temperatures and without the need for an energy-intensive light source.

  4. Treatment of landfill leachate by Fenton's reagent in a continuous stirred tank reactor

    International Nuclear Information System (INIS)

    Zhang Hui; Choi, H.J.; Huang, C.-P.

    2006-01-01

    The treatment of landfill leachate by Fenton process was carried out in a continuous stirred tank reactor (CSTR). The effect of operating conditions such as reaction time, hydraulic retention time, pH, H 2 O 2 to Fe(II) molar ratio, Fenton's reagent dosage, initial COD strength, and temperature on the efficacy of Fenton process was investigated. It is demonstrated that Fenton's reagent can effectively degrade leachate organics. Fenton process reached the steady state after three times of hydraulic retention. The oxidation of organic materials in the leachate was pH dependent and the optimal pH was 2.5. The favorable H 2 O 2 to Fe(II) molar ratio was 3, and organic removal increased as dosage increased at the favorable H 2 O 2 to Fe(II) molar ratio. Temperature gave a positive effect on organic removal

  5. Zn-Fe-CNTs catalytic in situ generation of H2O2 for Fenton-like degradation of sulfamethoxazole.

    Science.gov (United States)

    Liu, Yong; Fan, Qin; Wang, Jianlong

    2018-01-15

    A novel Fenton-like catalyst (Zn-Fe-CNTs) capable of converting O 2 to H 2 O 2 and further to OH was prepared through infiltration fusion method followed by chemical replacement in argon atmosphere. The catalyst was characterized by SEM, EDS, TEM, XRD and XPS. The reaction between Zn-Fe-CNTs and O 2 in aqueous solution could generate H 2 O 2 in situ, which was further transferred to OH. The Fenton-like degradation of sulfamethoxazole (SMX) using Zn-Fe-CNTs as catalyst was evaluated. The results indicated that Zn-Fe-CNTs had a coral porous structure with a BET area of 51.67m 2 /g, exhibiting excellent adsorption capacity for SMX, which enhanced its degradation. The particles of Zn 0 and Fe 0 /Fe 2 O 3 were observed on the surface of Zn-Fe-CNTs. The mixture of Zn 0 and CNTs could reduce O 2 into H 2 O 2 by micro-electrolysis and Fe 0 /Fe 2 O 3 could catalyze in-situ generation of H 2 O 2 to produce OH through Fenton-like process. When initial pH=1.5, T=25°C, O 2 flow rate=400mL/min, Zn-Fe-CNTs=0.6g/L, SMX=25mg/L and reaction time=10min, the removal efficiency of SMX and TOC was 100% and 51.3%, respectively. The intermediates were detected and the possible pathway of SMX degradation and the mechanism of Zn-Fe-CNTs/O 2 process were tentatively proposed. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Optimization of the electro-Fenton and solar photoelectro-Fenton treatments of sulfanilic acid solutions using a pre-pilot flow plant by response surface methodology

    International Nuclear Information System (INIS)

    El-Ghenymy, Abdellatif; Garcia-Segura, Sergi; Rodríguez, Rosa María; Brillas, Enric; El Begrani, Mohamed Soussi; Abdelouahid, Ben Ali

    2012-01-01

    Highlights: ► Quicker degradation of sulfanilic acid by solar photoelectro-Fenton than electro-Fenton. ► The same optimized current density, Fe 2+ content and pH for both processes by CCRD. ► Description of TOC, energy cost and current efficiency by response surface methodology. ► Fe(III)–carboxylate complexes as main by-products after electro-Fenton. ► Photolysis of these complexes by UV irradiation of sunlight in solar photoelectro-Fenton. - Abstract: A central composite rotatable design and response surface methodology were used to optimize the experimental variables of the electro-Fenton (EF) and solar photoelectro-Fenton (SPEF) degradations of 2.5 L of sulfanilic acid solutions in 0.05 M Na 2 SO 4 . Electrolyses were performed with a pre-pilot flow plant containing a Pt/air diffusion reactor generating H 2 O 2 . In SPEF, it was coupled with a solar photoreactor under an UV irradiation intensity of ca. 31 W m −2 . Optimum variables of 100 mA cm −2 , 0.5 mM Fe 2+ and pH 4.0 were determined after 240 min of EF and 120 min of SPEF. Under these conditions, EF gave 47% of mineralization, whereas SPEF was much more powerful yielding 76% mineralization with 275 kWh kg −1 total organic carbon (TOC) energy consumption and 52% current efficiency. Sulfanilic acid decayed at similar rate in both treatments following a pseudo-first-order kinetics. The final solution treated by EF contained a stable mixture of tartaric, acetic, oxalic and oxamic acids, which form Fe(III) complexes that are not attacked by hydroxyl radicals formed from H 2 O 2 and added Fe 2+ . The quick photolysis of these complexes by UV light of sunlight explains the higher oxidation power of SPEF. NH 4 + was the main inorganic nitrogen ion released in both processes.

  7. Industrial detergent wastewater treatment via fenton reagent

    International Nuclear Information System (INIS)

    Mohd Zairie Mohd Yusuff; Mohd Zulkifli Mohamad Noor; Izirwan Izhab

    2010-01-01

    Production of detergent can generates wastewater containing an organic matter with will consume an oxidation demand, surfactants, suspended solids, fat and oil. Besides, sulfate concentration is high in the most detergent plant effluent because of the sulphonation process that has physiological and toxic effects on marine organisms. Therefore, a research must be conducted to find the solution for this problem. The feasibility of Fentons reagent to treat detergent waste was investigated in this study. The sample of detergent wastewater was taken from FPG Oleo chemicals Sdn. Bhd. This experiment studied the effect of temperature towards the feasibility of Fentons reagent process besides the dosage between hydrogen peroxide (H 2 O 2 ) and ferrous ion (Fe 2+ ) in the reagent. While, evaluated efficiency of Fentons reagent in term of chemical oxygen demand (COD), total suspended solid (TSS) and the turbidity reduction within the experimental design. The result found that overall removal was achieved until 96.2 % in term of COD, 98.1 % in term of TSS and 99.6 % in term of turbidity using Fentons reagent process. Besides, also found that this process is optimum at temperature 35 degree Celsius are able to achieve the Standard A of Parameter Limit of Effluent of Standard A and Standard B were outlined by Department of Environment Malaysia (DOE) based on Environment Quality Act 1974. (author)

  8. Performance of Fluidized bed Fenton process in Degrading Acid Blue 113

    Science.gov (United States)

    Bello, M. M.; Raman, A. A.

    2017-06-01

    The performance of a fluidized bed Fenton process in degrading Acid Blue 113 (AB 113) was investigated. Fluidized bed Fenton process is a modification of conventional Fenton oxidation, aimed at reducing sludge generation and improving process performance. Response surface methodology was used to study the effects of operational parameter on the color removal from the dye. Dimensionless factors, Dye/Fe2+, H2O2/Fe2+ and pH were used as the independent variables in Box-Behnken Design (BDD). Reduced quadratic model was developed to predict the color removal. The process could remove up to 99 % of the initial color. The most significant factor for color removal was found to be Dye/Fe2+, followed by H2O2/Fe2+. Unlike conventional Fenton, the initial pH of the solution does not have a significant effect on the color removal.

  9. A novel and quick method to avoid H2O2 interference on COD measurement in Fenton system by Na2SO3 reduction and O2 oxidation

    DEFF Research Database (Denmark)

    Wang, Yong; Li, Weiguang; Angelidaki, Irini

    2013-01-01

    Hydrogen peroxide interference on chemical oxygen demand (COD) measurement has been a big problem in the application of the Fenton process. However, there is no simple and effective method available to address this problem, although several methods have been reported in the literature. In this st......Hydrogen peroxide interference on chemical oxygen demand (COD) measurement has been a big problem in the application of the Fenton process. However, there is no simple and effective method available to address this problem, although several methods have been reported in the literature...... to be effective in the matrix of Fenton treating real landfill leachate. Meanwhile, the procedure for this method in other applications was proposed in detail. To the best of our knowledge, this newly developed method is the most simple and effective way to avoid H2O2 interference on COD analysis....

  10. The catalytic oxidation of malachite green by the microwave-Fenton processes.

    Science.gov (United States)

    Zheng, Huaili; Zhang, Huiqin; Sun, Xiaonan; Zhang, Peng; Tshukudu, Tiroyaone; Zhu, Guocheng

    2010-01-01

    Catalytic oxidation of malachite green using the microwave-Fenton process was investigated. 0% of malachite green de-colorization using the microwave process and 23.5% of malachite green de-colorization using the Fenton process were observed within 5 minutes. In contrast 95.4% of malachite green de-colorization using the microwave-Fenton was observed in 5 minutes. During the microwave-Fenton process, the optimum operating conditions for malachite green de-colorization were found to be 3.40 of initial pH, 0.08 mmol/L of Fe2+ concentration and 12.5 mmol/L of H2O2 concentration. Confirmatory tests were carried out under the optimum conditions and the COD removal rate of 82.0% and the de-colorization rate of 99.0% were observed in 5 minutes. The apparent kinetics equation of -dC/dt=0.0337 [malachite green]0.9860[Fe2+)]0.8234[H2O2]0.1663 for malachite green de-colorization was calculated, which implied that malachite green was the dominant factor in determining the removal efficiency of malachite green based on microwave-Fenton process.

  11. Fate of citalopram during water treatment with O3, ClO2, UV and fenton oxidation

    DEFF Research Database (Denmark)

    Hörsing, Maritha; Kosjek, Tina; Andersen, Henrik Rasmus

    2012-01-01

    In the present study we investigate the fate of citalopram (CIT) at neutral pH using advanced water treatment technologies that include O3, ClO2 oxidation, UV irradiation and Fenton oxidation. The ozonation resulted in 80% reduction after 30 min treatment. Oxidation with ClO2 removed >90% CIT...... at a dosage of 0.1 mg L−1. During UV irradiation 85% reduction was achieved after 5 min, while Fenton with addition of 14 mg L−1 (Fe2+) resulted in 90% reduction of CIT. During these treatment experiments transformation products (TPs) were formed from CIT, where five compounds were identified by using high...

  12. Kinetic studies on the degradation of crystal violet by the Fenton oxidation process.

    Science.gov (United States)

    Wu, H; Fan, M M; Li, C F; Peng, M; Sheng, L J; Pan, Q; Song, G W

    2010-01-01

    The degradation of dye crystal violet (CV) by Fenton oxidation process was investigated. The UV-Vis spectrogram has shown that CV can be degraded effectively by Fenton oxidation process. Different system variables namely initial H(2)O(2) concentration, initial Fe(2 + ) concentration and reaction temperature, which have effect on the degradation of CV by Fenton oxidation process, have been studied systematically. The degradation kinetics of CV was also elucidated based on the experimental data. The degradation of CV obeys the first-order reaction kinetics. The kinetic model can be described as k=1.5 exp(-(7.5)/(RT))[H(2)O(2)](0)(0.8718)[Fe(2+)](0)(0.5062). According to the IR spectrogram, it is concluded that the benzene ring of crystal violet has been destroyed by Fenton oxidation. The result will be useful in treating dyeing wastewater containing CV by Fenton oxidation process.

  13. AN ADVANCED OXIDATION PROCESS : FENTON PROCESS

    Directory of Open Access Journals (Sweden)

    Engin GÜRTEKİN

    2008-03-01

    Full Text Available Biological wastewater treatment is not effective treatment method if raw wastewater contains toxic and refractory organics. Advanced oxidation processes are applied before or after biological treatment for the detoxification and reclamation of this kind of wastewaters. The advanced oxidation processes are based on the formation of powerful hydroxyl radicals. Among advanced oxidation processes Fenton process is one of the most promising methods. Because application of Fenton process is simple and cost effective and also reaction occurs in a short time period. Fenton process is applied for many different proposes. In this study, Fenton process was evaluated as an advanced oxidation process in wastewater treatment.

  14. Feasibility of bioleaching combined with Fenton oxidation to improve sewage sludge dewaterability.

    Science.gov (United States)

    Liu, Changgeng; Zhang, Panyue; Zeng, Chenghua; Zeng, Guangming; Xu, Guoyin; Huang, Yi

    2015-02-01

    A novel joint method of bioleaching with Fenton oxidation was applied to condition sewage sludge. The specific resistance to filtration (SRF) and moisture of sludge cake (MSC) were adopted to evaluate the improvement of sludge dewaterability. After 2-day bioleaching, the sludge pH dropped to about 2.5 which satisfied the acidic condition for Fenton oxidation. Meanwhile, the SRF declined from 6.45×10(10) to 2.07×10(10) s2/g, and MSC decreased from 91.42% to 87.66%. The bioleached sludge was further conditioned with Fenton oxidation. From an economical point of view, the optimal dosages of H2O2 and Fe2+ were 0.12 and 0.036 mol/L, respectively, and the optimal reaction time was 60 min. Under optimal conditions, SRF, volatile solids reduction, and MSC were 3.43×10(8) s2/g, 36.93%, and 79.58%, respectively. The stability and settleability of sewage sludge were both improved significantly. Besides, the results indicated that bioleaching-Fenton oxidation was more efficient in dewatering the sewage sludge than traditional Fenton oxidation. The sludge conditioning mechanisms by bioleaching-Fenton oxidation might mainly include the flocculation effects and the releases of extracellular polymeric substances-bound water and intercellular water. Copyright © 2014. Published by Elsevier B.V.

  15. Application of Fenton's reagent as a pretreatment step in biological degradation of polyaromatic hydrocarbons

    International Nuclear Information System (INIS)

    Kelley, R.L.; Gauger, W.K.; Srivastava, V.J.

    1991-01-01

    Fenton's reagent (H 2 O 2 and Fe ++ ) has been used for chemical oxidation of numerous organic compounds in water treatment schemes. In this study, the Institute of Gas Technology (IGT) applied Fenton's treatment to polynuclear aromatic hydrocarbons (PAHs) and PAH-contaminated soils. Fenton's treatment was very reactive with PAHs, causing rapid modification of the parental compounds to oxidized products and complete degradation to CO 2 . This treatment was more effective on chemically reactive PAHs, such as benzo(a)pyrene and phenanthrene. Important parameters and conditions for Fenton's treatment of PAHs in solution and soil matrices have been identified. As much as 99% of the PAHs on soil matrices can be removed by treatment with Fenton's reagent

  16. Pyrrolic-N-doped graphene oxide/Fe2O3 mesocrystal nanocomposite: Efficient charge transfer and enhanced photo-Fenton catalytic activity

    Science.gov (United States)

    Liu, Bing; Tian, Lihong; Wang, Ran; Yang, Jinfeng; Guan, Rong; Chen, Xiaobo

    2017-11-01

    Though α-Fe2O3 has attracted much attention in photocatalytic or Fenton-catalytic degradation of organic contaminants, its performance is still unsatisfactory due to fast recombination of electrons and holes in photocatalytic process and the difficult conversion of Fe(II) and Fe(III) in Fenton reaction. Herein, a pyrrolic N-doped graphene oxide/Fe2O3 mesocrystal (NG-Fe2O3) nanocomposite with good distribution is synthesized by a simple solvothermal method and adjusting the oxygen-containing groups on graphene oxide. The morphology of NG-Fe2O3 contributes to a relatively large BET surface area and an intimate contact between NG and Fe2O3. These two important factors along with the excellent electro-conductivity of pyrrolic-N doped GO result in the efficient separation of electron-hole pairs and fast conversion of Fe(II)and Fe(III) in photo-Fenton synergistic reaction. Thus, a remarkably improved photo-Fenton catalytic activity of NG-Fe2O3 is obtained. The degrading rate on methyl blue increases by 1.5 times and the conversion rate of glyphosate increases by 2.3 times under visible light irradiation, compared to pristine α-Fe2O3 mesocrystals.

  17. Quantifying Fenton reaction pathways driven by self-generated H2O2 on pyrite surfaces

    Science.gov (United States)

    Gil-Lozano, C.; Davila, A. F.; Losa-Adams, E.; Fairén, A. G.; Gago-Duport, L.

    2017-03-01

    Oxidation of pyrite (FeS2) plays a significant role in the redox cycling of iron and sulfur on Earth and is the primary cause of acid mine drainage (AMD). It has been established that this process involves multi-step electron-transfer reactions between surface defects and adsorbed O2 and H2O, releasing sulfoxy species (e.g., S2O32-, SO42-) and ferrous iron (Fe2+) to the solution and also producing intermediate by-products, such as hydrogen peroxide (H2O2) and other reactive oxygen species (ROS), however, our understanding of the kinetics of these transient species is still limited. We investigated the kinetics of H2O2 formation in aqueous suspensions of FeS2 microparticles by monitoring, in real time, the H2O2 and dissolved O2 concentration under oxic and anoxic conditions using amperometric microsensors. Additional spectroscopic and structural analyses were done to track the dependencies between the process of FeS2 dissolution and the degradation of H2O2 through the Fenton reaction. Based on our experimental results, we built a kinetic model which explains the observed trend of H2O2, showing that FeS2 dissolution can act as a natural Fenton reagent, influencing the oxidation of third-party species during the long term evolution of geochemical systems, even in oxygen-limited environments.

  18. Treatment of laundrette wastewater using Starbon and Fenton's reagent.

    Science.gov (United States)

    Tony, Maha A; Parker, Helen L; Clark, James H

    2016-09-18

    The use of grey water for a variety of purposes is gaining increased popularity as a means of preserving scarce freshwater resources. In this work, catalytic oxidation over Fenton's reagent and adsorption techniques using Starbon (mesoporous material derived from polysaccharides) has been applied. These novel techniques are used as an alternative to already studied treatments of grey water such as filtration and/or biological processes. In this study, grey water, collected from a commercial laundrette, has been used. Treatment efficiency was determined by changes in the chemical oxygen demand (COD) of the grey water. Experiments using Fenton's reagent at optimum conditions of Fe(3+) = 40 mg L(-1); H2O2 = 400 mg L(-1) and pH 3 were very successful, resulting in a 95% COD removal after 15 min. Treatment with Starbon adsorption was also effective, reaching up to 81% COD removal at pH 3 within 1 h. The combined treatment with Fenton's reagent and Starbon resulted in a 93% COD removal at a significantly reduced concentration of Fenton's reagent compared to the treatment with solo Fenton's reagent. This lower chemical dose has the advantage of reducing costs and lowering sludge generation.

  19. Hot dry rock geothermal energy development program. Annual report, fiscal year 1980

    Energy Technology Data Exchange (ETDEWEB)

    Cremer, G.M. (comp.)

    1981-07-01

    Investigation and flow testing of the enlarged Phase I heat-extraction system at Fenton Hill continued throughout FY80. Temperature drawdown observed at that time indicated an effective fracture of approximately 40,000 to 60,000 m/sup 2/. In May 1980, hot dry rock (HDR) technology was used to produce electricity in an interface demonstration experiment at Fenton Hill. A 60-kVA binary-cycle electrical generator was installed in the Phase I surface system and heat from about 3 kg/s of geothermal fluid at 132/sup 0/C was used to boil Freon R-114, whose vapor drove a turboalternator. A Phase II system was designed and is now being constructed at Fenton Hill that should approach commercial requirements. Borehole EE-2, the injection well, was completed on May 12, 1980. It was drilled to a vertical depth of about 4500 m, where the rock temperature is approximately 320/sup 0/C. The production well, EE-3 had been drilled to a depth of 3044 m and drilling was continuing. Environmental monitoring of Fenton Hill site continued. Development of equipment, instruments, and materials for technical support at Fenton Hill continued during FY80. Several kinds of models were also developed to understand the behavior of the Phase I system and to develop a predictive capability for future systems. Data from extensive resource investigations were collected, analyzed, and assembled into a geothermal gradient map of the US, and studies were completed on five specific areas as possible locations for HDR Experimental Site 2.

  20. Enhancement of Fenton processes at initial circumneutral pH for the degradation of norfloxacin with Fe@Fe2O3 core-shell nanomaterials.

    Science.gov (United States)

    Liu, Jingyi; Hu, Wenyong; Sun, Maogui; Xiong, Ouyang; Yu, Haibin; Feng, Haopeng; Wu, Xuan; Tang, Lin; Zhou, Yaoyu

    2018-06-13

    The degradation of norfloxacin by Fenton reagent with core-shell Fe@Fe 2 O 3 nanomaterials was studied under neutral conditions in a closed batch system. Norfloxacin was significantly degraded (90%) in the Fenton system with Fe@Fe 2 O 3 in 30 min at the initial pH 7.0, but slightly degraded in Fenton system without Fe@Fe 2 O 3 under the same experimental conditions. The intermediate products were investigated by gas chromatography-mass spectrometry, and the possible Fenton oxidation pathway of norfloxacin in the presence of Fe@Fe 2 O 3 nanowires was proposed. Electron spin resonance spectroscopy was used to identify and characterize the free radicals generated, and the mechanism for norfloxacin degradation was also revealed. Finally, the reusability and the stability of Fe@Fe 2 O 3 nanomaterials were studied using x-ray diffraction and scanning electron microscope, which indicated that Fe@Fe 2 O 3 is a stable catalyst and can be used repetitively in environmental pollution control.

  1. Heterogeneous photo-Fenton degradation of acid red B over Fe{sub 2}O{sub 3} supported on activated carbon fiber

    Energy Technology Data Exchange (ETDEWEB)

    Lan, Huachun [Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences,China (China); Wang, Aiming [Department of Municipal and Environmental Engineering, School of Civil Engineering, Beijing Jiaotong University,China (China); Liu, Ruiping, E-mail: liuruiping@rcees.ac.cn [Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences,China (China); Liu, Huijuan; Qu, Jiuhui [Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences,China (China)

    2015-03-21

    Highlights: • Fe{sub 2}O{sub 3} with small particle size was highly dispersed on activated carbon fiber. • Fe{sub 2}O{sub 3}/ACF exhibited higher photo-Fenton activity toward ARB degradation. • Fe{sub 2}O{sub 3}/ACF has an excellent long-term stability without obvious deactivation. - Abstract: Fe{sub 2}O{sub 3} supported on activated carbon fiber (Fe{sub 2}O{sub 3}/ACF) was prepared via an impregnation method and characterized by X-ray diffraction, scanning electron microscopy and BET analysis. The results indicated that Fe{sub 2}O{sub 3} with small particle size was highly dispersed on the surface of the ACF and the introduction of Fe{sub 2}O{sub 3} did not change the ACF pore structure. Fe{sub 2}O{sub 3}/ACF exhibited a higher Fenton efficiency for the degradation of acid red B (ARB), especially under simulated solar irradiation. Complete decoloration of the ARB solution and 43% removal of TOC could be achieved within 200 min under optimal conditions. It was verified that more ·OH radicals were generated in the photo-assisted Fenton process and involved as active species in ARB degradation. FTIR analysis indicated that the degradation of ARB was initiated through the cleavage of −N=N−, followed by hydroxylation and opening of phenyl rings to form aliphatic acids, and further oxidation of aliphatic acids would produce CO{sub 2} and H{sub 2}O. Moreover, Fe{sub 2}O{sub 3}/ACF maintained its activity after being reused 4 times and the release of iron from the catalyst was found to be insignificant during the Fenton and photo-Fenton processes, indicating that Fe{sub 2}O{sub 3}/ACF had good long-term stability.

  2. Photo-Fenton and Fenton-like processes for the treatment of the antineoplastic drug 5-fluorouracil under simulated solar radiation.

    Science.gov (United States)

    Koltsakidou, Α; Antonopoulou, M; Sykiotou, M; Εvgenidou, Ε; Konstantinou, I; Lambropoulou, D A

    2017-02-01

    In the present study, photo-Fenton and Fenton-like processes were investigated for the degradation and mineralization of the antineoplastic drug 5-fluorouracil (5-FU). For the optimization of photo-Fenton treatment under simulated solar light (SSL) radiation, the effects of several operating parameters (i.e., 5-FU concentration, Fe 3+ , and oxidant concentration) on the treatment efficiency were studied. According to the results, SSL/[Fe(C 2 Ο 4 ) 3 ] 3- /Η 2 Ο 2 process was the most efficient, since faster degradation of 5-FU and higher mineralization percentages were achieved. All the applied processes followed quite similar transformation routes which include defluorination-hydroxylation as well as pyrimidine ring opening, as demonstrated by the transformation products identified by high resolution mass spectrometry analysis. The toxicity of the treated solutions was evaluated using the Microtox assay. In general, low toxicity was recorded for the initial solution and the solution at the end of the photocatalytic treatment, while an increase in the overall toxicity was observed only at the first stages of SSL/Fe 3+ /Η 2 Ο 2 and SSL/Fe 3+ /S 2 O 8 2- processes.

  3. Photonic efficiency of the photodegradation of paracetamol in water by the photo-Fenton process.

    Science.gov (United States)

    Yamal-Turbay, E; Ortega, E; Conte, L O; Graells, M; Mansilla, H D; Alfano, O M; Pérez-Moya, M

    2015-01-01

    An experimental study of the homogeneous Fenton and photo-Fenton degradation of 4-amidophenol (paracetamol, PCT) is presented. For all the operation conditions evaluated, PCT degradation is efficiently attained by both Fenton and photo-Fenton processes. Also, photonic efficiencies of PCT degradation and mineralization are determined under different experimental conditions, characterizing the influence of hydrogen peroxide (H2O2) and Fe(II) on both contaminant degradation and sample mineralization. The maximum photonic degradation efficiencies for 5 and 10 mg L(-1) Fe(II) were 3.9 (H2O2 = 189 mg L(-1)) and 5 (H2O2 = 378 mg L(-1)), respectively. For higher concentrations of oxidant, H2O2 acts as a "scavenger" radical, competing in pollutant degradation and reducing the reaction rate. Moreover, in order to quantify the consumption of the oxidizing agent, the specific consumption of the hydrogen peroxide was also evaluated. For all operating conditions of both hydrogen peroxide and Fe(II) concentration, the consumption values obtained for Fenton process were always higher than the corresponding values observed for photo-Fenton. This implies a less efficient use of the oxidizing agent for dark conditions.

  4. Environmental application of millimetre-scale sponge iron (s-Fe"0) particles (IV): New insights into visible light photo-Fenton-like process with optimum dosage of H_2O_2 and RhB photosensitizers

    International Nuclear Information System (INIS)

    Ju, Yongming; Yu, Yunjiang; Wang, Xiaoyan; Xiang, Mingdeng; Li, Liangzhong; Deng, Dongyang; Dionysiou, Dionysios D.

    2017-01-01

    Highlights: • Synergistic action of Rhodamine B (RhB), visible light, H_2O_2 and s-Fe"0 is essential. • The complexes of RhB and Fe"3"+ eject one electron via ligand-to-metal charge-transfer. • RhB assists the photo-Fenton-like removal of tetrabromobisphenol A (TBBPA). - Abstract: In this study, we firstly develop the photo-Fenton-like system with millimetric sponge iron (s-Fe"0), H_2O_2, visible light (vis, λ ≥ 420 nm) and rhodamine B (RhB), and present a comprehensive study concerning the mechanism. Thus, we investigate (1) the adsorption of RhB onto s-Fe"0, (2) the photo-Fenton-like removal of RhB over iron oxides generated from the corrosion of s-Fe"0, (3) the homogeneous photo-Fenton removal of RhB over Fe"2"+ or Fe"3"+, (4) the Fe"3"+-RhB complexes, and (5) the photo-Fenton-like removal of tetrabromobisphenol A (TBBPA). The results show that neither the adsorption process over s-Fe"0 nor the photo-Fenton-like process over FeOOH, Fe_3O_4 and Fe_2O_3, achieved efficient removal of RhB. For comparison, in homogeneous photo-Fenton process, the presence of Fe"3"+ ions, rather than Fe"2"+ ions, effectively eliminated RhB. Furthermore, the UV–vis spectra showing new absorbance at ∼ 285 nm indicate the complexes of RhB and Fe"3"+ ions, adopting vis photons to form excited state and further eject one electron via ligand-to-metal charge-transfer to activate H_2O_2. Additionally, efficient TBBPA removal was obtained only in the presence of RhB. Accordingly, the s-Fe"0– based photo-Fenton-like process assisted with dyestuff wastewater is promising for removing a series of persistent organic pollutants.

  5. Degradation of Anthraquinone Dye Reactive Blue 4 in Pyrite Ash Catalyzed Fenton Reaction

    Directory of Open Access Journals (Sweden)

    Milena Becelic-Tomin

    2014-01-01

    Full Text Available Pyrite ash (PA is created by burning pyrite in the chemical production of sulphuric acid. The high concentration of iron oxide, mostly hematite, present in pyrite ash, gives the basis for its application as a source of catalytic iron in a modified Fenton process for anthraquinone dye reactive blue 4 (RB4 degradation. The effect of various operating variables such as catalyst and oxidant concentration, initial pH and RB4 concentration on the abatement of total organic carbon, and dye has been assessed in this study. Here we show that degradation of RB4 in the modified Fenton reaction was efficient under the following conditions: pH=2.5; [PA]0=0.2 g L−1; [H2O2]0=5 mM and initial RB4 concentration up to 100 mg L−1. The pyrite ash Fenton reaction can overcome limitations observed from the classic Fenton reaction, such as the early termination of the Fenton reaction. Metal (Pb, Zn, and Cu content of the solution after the process suggests that an additional treatment step is necessary to remove the remaining metals from the water. These results provide basic knowledge to better understand the modified, heterogeneous Fenton process and apply the PA Fenton reaction for the treatment of wastewaters which contains anthraquinone dyes.

  6. Textile wastewater reuse after additional treatment by Fenton's reagent.

    Science.gov (United States)

    Ribeiro, Marília Cleto Meirelles; Starling, Maria Clara V M; Leão, Mônica Maria Diniz; de Amorim, Camila Costa

    2017-03-01

    This study verifies textile wastewater reuse treated by the conventional activated sludge process and subjected to further treatment by advanced oxidation processes. Three alternative processes are discussed: Fenton, photo-Fenton, and UV/H 2 O 2 . Evaluation of treatments effects was based on factorial experiment design in which the response variables were the maximum removal of COD and the minimum concentration of residual H 2 O 2 in treated wastewater. Results indicated Fenton's reagent, COD/[H 2 O 2 ]/[Fe 2+ ] mass ratio of 1:2:2, as the best alternative. The selected technique was applied to real wastewater collected from a conventional treatment plant of a textile mill. The quality of the wastewater before and after the additional treatment was monitored in terms of 16 physicochemical parameters defined as suitable for the characterization of waters subjected to industrial textile use. The degradation of the wastewater was also evaluated by determining the distribution of its molecular weight along with the organic matter fractionation by ultrafiltration, measured in terms of COD. Finally, a sample of the wastewater after additional treatment was tested for reuse at pilot scale in order to evaluate the impact on the quality of dyed fabrics. Results show partial compliance of treated wastewater with the physicochemical quality guidelines for reuse. Removal and conversion of high and medium molecular weight substances into low molecular weight substances was observed, as well as the degradation of most of the organic matter originally present in the wastewater. Reuse tests indicated positive results, confirming the applicability of wastewater reuse after the suggested additional treatment. Graphical abstract Textile wastewater samples after additional treatment by Fenton's reagent, photo-Fenton and H 2 O 2 /UV tested in different conditions.

  7. Removal of phosphonates from industrial wastewater with UV/FeII, Fenton and UV/Fenton treatment.

    Science.gov (United States)

    Rott, Eduard; Minke, Ralf; Bali, Ulusoy; Steinmetz, Heidrun

    2017-10-01

    Phosphonates are an important group of phosphorus-containing compounds due to their increasing industrial use and possible eutrophication potential. This study involves investigations into the methods UV/Fe II , Fenton and UV/Fenton for their removal from a pure water matrix and industrial wastewaters. It could be shown that the degradability of phosphonates by UV/Fe II (6 kWh/m 3 ) in pure water crucially depended on the pH and was higher the less phosphonate groups a phosphonate contains. The UV/Fe II method is recommended in particular for the treatment of concentrates with nitrogen-free phosphonates, only little turbidity and a low content of organic compounds. Using Fenton reagent, the degradation of polyphosphonates was relatively weak in a pure water matrix (Fenton method (6 kWh/m 3 ), those phosphonates with the smallest numbers of phosphonate groups were easier degraded as well at pH 3.5 in a pure water matrix (o-PO 4 3- formation rates of up to 80%). Despite an incomplete transformation of organically bound phosphorus to o-PO 4 3- with Fenton reagent in an organically highly polluted wastewater (max. 15%), an almost total removal of the total P occurred. The most efficient total P elimination rates were achieved in accordance with the following Fenton implementation: reaction → sludge separation (acidic) → neutralization of the supernatant → sludge separation (neutral). Accordingly, a neutralization directly after the reaction phase led to a lower total P removal extent. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Overview of Hole GT2A: Drilling middle gabbro in Wadi Tayin massif, Oman ophiolite

    Science.gov (United States)

    Takazawa, E.; Kelemen, P. B.; Teagle, D. A. H.; Coggon, J. A.; Harris, M.; Matter, J. M.; Michibayashi, K.

    2017-12-01

    Hole GT2A (UTM: 40Q 655960.7E / 2529193.5N) was drilled by the Oman Drilling Project (OmDP) into Wadi Gideah of Wadi Tayin massif in the Samail ophiolite, Oman. OmDP is an international collaboration supported by the International Continental Scientific Drilling Program, the Deep Carbon Observatory, NSF, IODP, JAMSTEC, and the European, Japanese, German and Swiss Science Foundations, with in-kind support in Oman from the Ministry of Regional Municipalities and Water Resources, Public Authority of Mining, Sultan Qaboos University, and the German University of Technology. Hole GT2A was diamond cored in 25 Dec 2016 to 18 Jan 2017 to a total depth of 406.77 m. The outer surfaces of the cores were imaged and described on site before being curated, boxed and shipped to the IODP drill ship Chikyu, where they underwent comprehensive visual and instrumental analysis. 33 shipboard scientists were divided into six teams (Igneous, Alteration, Structural, Geochem, Physical Properties, Paleomag) to describe and analyze the cores. Hole GT2A drilled through the transition between foliated and layered gabbro. The transition zone occurs between 50 and 150 m curation corrected depth (CCD). The top 50 m of Hole GT2A is foliated gabbro whereas the bottom 250 m consists of layered gabbro. Brittle fracture is observed throughout the core. Intensity of alteration vein decreases from the top to the bottom of the hole. On the basis of changes in grain size and/or modal abundance and/or appearance/disappearance of igneous primary mineral(s) five lithological units are defined in Hole GT2A (Unit I to V). The uppermost part of Hole GT2A (Unit I) is dominated by fine-grained granular olivine gabbro intercalated with less dominant medium-grained granular olivine gabbro and rare coarse-grained varitextured gabbro. The lower part of the Hole (Units II, III and V) is dominated by medium-grained olivine gabbro, olivine melagabbro and olivine-bearing gabbro. Modally-graded rhythmic layering with

  9. Effects of reaction conditions on nuclear laundry water treatment in Fenton process

    International Nuclear Information System (INIS)

    Vilve, Miia; Hirvonen, Arja; Sillanpaeae, Mika

    2009-01-01

    This study presents the efficiency of Fenton process in the degradation of organic compounds of nuclear laundry water. The influence of Fe 2+ and hydrogen peroxide ratio, hydrogen peroxide dose, pH and treatment time were investigated. The degradation of non-ionic surfactant and other organic compounds was analysed as COD, TOC and molecular weight distribution (MWD). The most cost-effective degradation conditions were at H 2 O 2 /Fe 2+ stoichiometric molar ratio of 2 with 5 min mixing and H 2 O 2 dose of 1000 mg l -1 . With the initial pH of 6, the reductions of COD and TOC were 85% and 69%, respectively. However, the removal of the organic compounds was mainly carried out by Fenton-based Fe 3+ coagulation rather than Fenton oxidation. Fenton process proved to be much more efficient than previously performed ozone-based oxidation processes.

  10. Structural characterization of O- and C-glycosylating variants of the landomycin glycosyltransferase LanGT2.

    Science.gov (United States)

    Tam, Heng Keat; Härle, Johannes; Gerhardt, Stefan; Rohr, Jürgen; Wang, Guojun; Thorson, Jon S; Bigot, Aurélien; Lutterbeck, Monika; Seiche, Wolfgang; Breit, Bernhard; Bechthold, Andreas; Einsle, Oliver

    2015-02-23

    The structures of the O-glycosyltransferase LanGT2 and the engineered, C-C bond-forming variant LanGT2S8Ac show how the replacement of a single loop can change the functionality of the enzyme. Crystal structures of the enzymes in complex with a nonhydrolyzable nucleotide-sugar analogue revealed that there is a conformational transition to create the binding sites for the aglycon substrate. This induced-fit transition was explored by molecular docking experiments with various aglycon substrates. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Comparison of TiO2 photocatalysis, electrochemically assisted Fenton reaction and direct electrochemistry for simulation of phase I metabolism reactions of drugs

    NARCIS (Netherlands)

    Ruokolainen, Miina; Gül, Turan; Permentier, Hjalmar; Sikanen, Tiina; Kostiainen, Risto; Kotiaho, Tapio

    2016-01-01

    The feasibility of titanium dioxide (TiO2) photocatalysis, electrochemically assisted Fenton reaction (EC-Fenton) and direct electrochemical oxidation (EC) for simulation of phase I metabolism of drugs was studied by comparing the reaction products of buspirone, promazine, testosterone and

  12. Improved removal performance and mechanism investigation of papermaking wastewater treatment using manganese enhanced Fenton reaction.

    Science.gov (United States)

    Wang, Yingcai; Wang, Can; Shi, Shuai; Fang, Shuai

    2018-06-01

    The effects of Mn(II) on Fenton system to treat papermaking wastewater and the mechanism of Mn(II) enhanced Fenton reaction were investigated in this study. The chemical oxygen demand (COD) removal efficiency was enhanced in the presence of Mn(II), which increased by 19% compared with that of the Fenton system alone. The pseudo-first order reaction kinetic rate constant of Mn(II)/Fenton system was 2.11 times higher than that of Fenton system. 67%-81% COD were removed with the increasing Mn(II) concentration from 0 to 0.8 g/L. COD removal efficiency was also enhanced in a wider pH range (3-7), which indicated the operation parameters of Fenton technology could be broadened to a milder condition. The study of the mechanism showed that Mn(II) participated in the oxidation and coagulation stages in Fenton system. In the oxidation stage, Mn(II) promotes the production of HO 2 •/ O 2 • - , then HO 2 •/ O 2 • - reacts with Fe(III) to accelerate the formation of Fe(II), and finally accelerates the production of HO•. Meantime MnMnO 3 and Fe(OH) 3 forms in the coagulation stage, facilitating the removal of suspended substances and a large amount of COD, which enhances the overall COD removal of papermaking wastewater. This study provided a detailed mechanism to improve practical applications of Fenton technology.

  13. Degradation of ethylparaben under simulated sunlight using photo-Fenton.

    Science.gov (United States)

    Zúñiga-Benítez, Henry; Peñuela, Gustavo A

    2016-01-01

    Ethylparaben (EPB) has been classified by different research groups as a potential endocrine-disrupting chemical, implying that it can potentially interfere with the normal balance of the endocrine system of living beings, which with its presence in different effluents, including drinking water, generates the need to seek methods that allow its removal from different water bodies. Advanced oxidation processes have been employed widely to remove organic compounds from different matrices. In this way, Fenton technology (process based on the reaction between ferrous ions and hydrogen peroxide) has been able to degrade different substrates, but due to the Fe(2+) requirements to carry out the reaction optimally, combination of the conventional Fenton process with visible light radiation (photo-Fenton) is an alternative used in the treatment of pollution due to the presence of chemicals. In this way, the effectiveness of photo-Fenton on EPB degradation was assessed using a face-centered central composite experimental design that allowed assessment of the effects of Fe(2+) and H2O2 initial concentrations on process. In general, results indicated that after 180 min of reaction almost all EPB was eliminated, the dissolved organic carbon in solution was reduced and the sample biodegradability index was increased.

  14. Treatment of real paracetamol wastewater by fenton process

    Directory of Open Access Journals (Sweden)

    Dalgic Gamze

    2017-01-01

    Full Text Available The study investigated the pretreatment of real paracetamol (PCT wastewater of a pharmaceutical industry by Fenton process. At the best experimental conditions (COD/H2O2 = 1/1, Fe+2/H2O2 = 1/70, settling method:centrifuging, pH 6 at settling step, 92.7, 92.7, 95.5, 99.1, 99.9 and 99.4% of chemical oxygen demand (COD, total organic carbon (TOC, 5-day biological oxygen demand (BOD5, PCT, para-amino phenol (PAP and aniline were removed, respectively. Changes in the concentrations of these parameters were also investigated for both oxidation and settling steps of Fenton process. It was found that COD and TOC were removed at the settling step (precipitation whereas PCT, PAP and aniline were removed at the oxidation step. Mass balance calculations were also studied to show the mass distributions of COD in different phases (gas + foam, effluent and sludge. Fenton process was found as an effective method for the pretreatment of real PCT wastewater for discharging in a determined collective treatment plant.

  15. Electrokinetic-Fenton remediation of organochlorine pesticides from historically polluted soil.

    Science.gov (United States)

    Ni, Maofei; Tian, Shulei; Huang, Qifei; Yang, Yanmei

    2018-04-01

    Soil contamination by persistent organic pollutants (POPs) poses a great threat to historically polluted soil worldwide. In this study, soils were characterized, and organochlorine pesticides contained in the soils were identified and quantified. Individual electrokinetic (IE), EK-Fenton-coupled technologies (EF), and enhanced EK-Fenton treatment (E-1, E-2, and E-3) were applied to remediate soils contaminated with hexachloro-cyclohexane soprocide (HCH) and dichloro-diphenyl-trichloroethane (DDT). Variation of pH, electrical conductivity, and electroosmotic flow was evaluated during the EK-Fenton process. The IE treatment showed low removal efficiency for HCHs (30.5%) and DDTs (25.9%). In the EF treatment, the highest removal level (60.9%) was obtained for α-HCH, whereas P,P-DDT was the lowest (40.0%). Low solubility of pollutants impeded the HCH and DDT removal. After enhanced EK-Fenton treatment, final removal of pollutants decreased as follows: β-HCH (82.6%) > γ-HCH (81.6%) > α-HCH (81.2%) > δ-HCH (80.0%) > P,P-DDD (73.8%) > P,P-DDE (73.1%) > P,P-DDT (72.6%) > O,P-DDT (71.5%). The results demonstrate that EK-Fenton is a promising technology for POP removal in historically polluted soil.

  16. Mineralisation of 2,4-dichlorophenoxyacetic acid by acoustic or hydrodynamic cavitation in conjunction with the advanced Fenton process.

    Science.gov (United States)

    Bremner, David H; Carlo, Stefano Di; Chakinala, Anand G; Cravotto, Giancarlo

    2008-04-01

    The mineralisation of 2,4-dichlorophenoxyacetic acid (2,4-D) in the presence of zero-valent iron and hydrogen peroxide (the advanced Fenton process--AFP) whilst being subjected to acoustic or hydrodynamic cavitation is reported. If the reaction is merely stirred then there is 57% removal of TOC whilst on irradiation the figure is 64% although the latter reaction is more rapid. Use of ultrasound alone results in only 11% TOC removal in 60 min of treatment time. Addition of iron powder marginally enhances the extent of degradation but an appreciable increase is observed in the presence of hydrogen peroxide which acts as a source for hydroxyl radicals by Fenton chemistry as well as by dissociation in the presence of ultrasound. The use of hydrodynamic cavitation in conjunction with the advanced Fenton process has also been found to be a useful tool for continuous remediation of water contaminated with 2,4-D. After 20 min of treatment the residual TOC is reduced to 30% and this probably represents the remaining highly recalcitrant small organic molecules.

  17. Advanced Treatment of Pesticide-Containing Wastewater Using Fenton Reagent Enhanced by Microwave Electrodeless Ultraviolet

    Directory of Open Access Journals (Sweden)

    Gong Cheng

    2015-01-01

    Full Text Available The photo-Fenton reaction is a promising method to treat organic contaminants in water. In this paper, a Fenton reagent enhanced by microwave electrodeless ultraviolet (MWEUV/Fenton method was proposed for advanced treatment of nonbiodegradable organic substance in pesticide-containing biotreated wastewater. MWEUV lamp was found to be more effective for chemical oxygen demand (COD removal than commercial mercury lamps in the Fenton process. The pseudo-first order kinetic model can well describe COD removal from pesticide-containing wastewater by MWEUV/Fenton, and the apparent rate constant (k was 0.0125 min−1. The optimal conditions for MWEUV/Fenton process were determined as initial pH of 5, Fe2+ dosage of 0.8 mmol/L, and H2O2 dosage of 100 mmol/L. Under the optimal conditions, the reaction exhibited high mineralization degrees of organics, where COD and dissolved organic carbon (DOC concentration decreased from 183.2 mg/L to 36.9 mg/L and 43.5 mg/L to 27.8 mg/L, respectively. Three main pesticides in the wastewater, as Dimethoate, Triazophos, and Malathion, were completely removed by the MWEUV/Fenton process within 120 min. The high degree of pesticides decomposition and mineralization was proved by the detected inorganic anions.

  18. Comparison of TiO2 photocatalysis, electrochemically assisted Fenton reaction and direct electrochemistry for simulation of phase I metabolism reactions of drugs.

    Science.gov (United States)

    Ruokolainen, Miina; Gul, Turan; Permentier, Hjalmar; Sikanen, Tiina; Kostiainen, Risto; Kotiaho, Tapio

    2016-02-15

    The feasibility of titanium dioxide (TiO2) photocatalysis, electrochemically assisted Fenton reaction (EC-Fenton) and direct electrochemical oxidation (EC) for simulation of phase I metabolism of drugs was studied by comparing the reaction products of buspirone, promazine, testosterone and 7-ethoxycoumarin with phase I metabolites of the same compounds produced in vitro by human liver microsomes (HLM). Reaction products were analysed by UHPLC-MS. TiO2 photocatalysis simulated the in vitro phase I metabolism in HLM more comprehensively than did EC-Fenton or EC. Even though TiO2 photocatalysis, EC-Fenton and EC do not allow comprehensive prediction of phase I metabolism, all three methods produce several important metabolites without the need for demanding purification steps to remove the biological matrix. Importantly, TiO2 photocatalysis produces aliphatic and aromatic hydroxylation products where direct EC fails. Furthermore, TiO2 photocatalysis is an extremely rapid, simple and inexpensive way to generate oxidation products in a clean matrix and the reaction can be simply initiated and quenched by switching the UV lamp on/off. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Fenton-Like Oxidation of Malachite Green Solutions: Kinetic and Thermodynamic Study

    Directory of Open Access Journals (Sweden)

    Saeedeh Hashemian

    2013-01-01

    Full Text Available Oxidation by Fenton-like (Fe3+/H2O2 reactions is proven to be an economically feasible process for destruction of a variety of hazardous pollutants in wastewater. In this study, the degradation and mineralization of malachite green dye are reported using Fenton-like reaction. The effects of different parameters like pH of the solution, the initial concentrations of Fe3+, H2O2, and dye, temperature, and added electrolytes (Cl− and on the oxidation of the dye were investigated. Optimized condition was determined. The efficiency of 95.5% degradation of MAG after 15 minutes of reaction at pH 3 was obtained. TOC removal indicates partial and insignificant mineralization of malachite green dye. The results of experiments showed that degradation of malachite green dye in Fenton-like oxidation process can be described with a pseudo-second-order kinetic model. The thermodynamic constants of the Fenton oxidation process were evaluated. The results implied that the oxidation process was feasible, spontaneous, and endothermic. The results will be useful for designing the treatment systems of various dye-containing wastewaters.

  20. Tunable, Quantitative Fenton-RAFT Polymerization via Metered Reagent Addition.

    Science.gov (United States)

    Nothling, Mitchell D; McKenzie, Thomas G; Reyhani, Amin; Qiao, Greg G

    2018-05-10

    A continuous supply of radical species is a key requirement for activating chain growth and accessing quantitative monomer conversions in reversible addition-fragmentation chain transfer (RAFT) polymerization. In Fenton-RAFT, activation is provided by hydroxyl radicals, whose indiscriminate reactivity and short-lived nature poses a challenge to accessing extended polymerization times and quantitative monomer conversions. Here, an alternative Fenton-RAFT procedure is presented, whereby radical generation can be finely controlled via metered dosing of a component of the Fenton redox reaction (H 2 O 2 ) using an external pumping system. By limiting the instantaneous flux of radicals and ensuring sustained radical generation over tunable time periods, metered reagent addition reduces unwanted radical "wasting" reactions and provides access to consistent quantitative monomer conversions with high chain-end fidelity. Fine tuning of radical concentration during polymerization is achieved simply via adjustment of reagent dose rate, offering significant potential for automation. This modular strategy holds promise for extending traditional RAFT initiation toward more tightly regulated radical concentration profiles and affords excellent prospects for the automation of Fenton-RAFT polymerization. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Decolorizing textile wastewater with Fenton's reagent electrogenerated with a solar photovoltaic cell.

    Science.gov (United States)

    Figueroa, Sandra; Vázquez, Leticia; Alvarez-Gallegos, A

    2009-02-01

    In this work it is demonstrated that Fenton's reagent can be electroproduced with abundant and cheap feedstock: oxygen saturated wastewater and solar energy. Experiments were carried out in a divided electrochemical flow cell using two electrodes: a three dimensional reticulated vitreous carbon cathode and stainless steel anode. Fenton's reagent is produced by oxygen reduction on the cathode in the presence of 1mM Fe(2+). The influence of electrolyte nature and its concentration and potential difference on the current efficiency, as well as the rate of Fenton's reagent electroproduction is discussed and it is concluded that over this extended range of conditions the current efficiency, for Fenton's reagent production, fell within the range 50-70%. It is possible to electroproduce a stoichiometric amount of Fenton reagent for the oxidation of 0.061mM Reactive Black 5 (in tap water+0.05M Na(2)SO(4), approximately pH 2.8). Similar results were obtained for solutions containing 0.1mM Acid Green 25. Some practical applications in the field of water treatment are included. The energy required for drive electrochemical reaction is supplied to the flow cell by means of a commercial solar panel.

  2. Photo-assisted Fenton type processes for the degradation of phenol: A kinetic study

    International Nuclear Information System (INIS)

    Kusic, Hrvoje; Koprivanac, Natalija; Bozic, Ana Loncaric; Selanec, Iva

    2006-01-01

    In this study the application of advanced oxidation processes (AOPs), dark Fenton and photo-assisted Fenton type processes; Fe 2+ /H 2 O 2 , Fe 3+ /H 2 O 2 , Fe 0 /H 2 O 2 , UV/Fe 2+ /H 2 O 2 , UV/Fe 3+ /H 2 O 2 and UV/Fe 0 /H 2 O 2 , for degradation of phenol as a model organic pollutant in the wastewater was investigated. A detail kinetic modeling which describes the degradation of phenol was performed. Mathematical models which predict phenol decomposition and formation of primary oxidation by-products: catechol, hydroquinone and benzoquinone, by applied processes were developed. The study also consist the modeling of mineralization kinetic of the phenol solution by applied AOPs. This part, besides well known reactions of Fenton and photo-Fenton chemistry, involves additional reactions which describe removal of iron from catalytic cycle through formation of ferric complexes and its regeneration induced by UV radiation. Phenol decomposition kinetic was monitored by HPLC analysis and total organic carbon content measurements (TOC). Complete phenol removal was obtained by all applied processes. Residual TOC by applied Fenton type processes ranged between 60.2 and 44.7%, while the efficiency of those processes was significantly enhanced in the presence of UV light, where residual TOC ranged between 15.2 and 2.4%

  3. Combined heterogeneous Electro-Fenton and biological process for the treatment of stabilized landfill leachate.

    Science.gov (United States)

    Baiju, Archa; Gandhimathi, R; Ramesh, S T; Nidheesh, P V

    2018-03-15

    Treatment of stabilized landfill leachate is a great challenge due to its poor biodegradability. Present study made an attempt to treat this wastewater by combining electro-Fenton (E-Fenton) and biological process. E-Fenton treatment was applied prior to biological process to enhance the biodegradability of leachate, which will be beneficial for the subsequent biological process. This study also investigates the efficiency of iron molybdophosphate (FeMoPO) nanoparticles as a heterogeneous catalyst in E-Fenton process. The effects of initial pH, catalyst dosage, applied voltage and electrode spacing on Chemical Oxygen Demand (COD) removal efficiency were analyzed to determine the optimum conditions. Heterogeneous E-Fenton process gave 82% COD removal at pH 2, catalyst dosage of 50 mg/L, voltage 5 V, electrode spacing 3 cm and electrode area 25 cm 2 . Combined E-Fenton and biological treatment resulted an overall COD removal of 97%, bringing down the final COD to 192 mg/L. Copyright © 2018 Elsevier Ltd. All rights reserved.

  4. Magnetic field assisted Fenton reactions for the enhanced degradation of methyl blue

    Institute of Scientific and Technical Information of China (English)

    Xiao Long Hao; Lu Yi Zou; Guang Sheng Zhang; Yi Bo Zhang

    2009-01-01

    Magnetic field was tentatively introduced into Fenton reactions system for the degradation and discoloration of methyl blue as the represent of organic chemical dye, which was a bio-refractory organic pollutant in industry wastewater. It was found that under optimal Fenton reaction conditions, with the assistant of magnetic field in Fenton reactions, the degradation rate of methyl blue, the decomposition rate of H2O2 and the conversion rate of Fe2+ were accelerated, the extent of them would be improved by the increase of magnetic field intensity. Meanwhile, the mineralization of methyl blue (CODcr) was improved by over 10% with magnetic fiold.

  5. Application of solar photo-Fenton toward toxicity removal and textile wastewater reuse.

    Science.gov (United States)

    Starling, Maria Clara V M; Dos Santos, Paulo Henrique Rodrigues; de Souza, Felipe Antônio Ribeiro; Oliveira, Sílvia Corrêa; Leão, Mônica M D; Amorim, Camila C

    2017-05-01

    Solar photo-Fenton represents an innovative and low-cost option for the treatment of recalcitrant industrial wastewater, such as the textile wastewater. Textile wastewater usually shows high acute toxic and variability and may be composed of many different chemical compounds. This study aimed at optimizing and validating solar photo-Fenton treatment of textile wastewater in a semi-pilot compound parabolic collector (CPC) for toxicity removal and wastewater reclamation. In addition, treated wastewater reuse feasibility was investigated through pilot tests. Experimental design performed in this study indicated optimum condition for solar photo-Fenton reaction (20 mg L -1 of Fe 2+ and 500 mg L -1 of H 2 O 2 ; pH 2.8), which achieved 96 % removal of dissolved organic carbon (DOC) and 99 % absorbance removal. A toxicity peak was detected during treatment, suggesting that highly toxic transformation products were formed during reaction. Toxic intermediates were properly removed during solar photo-Fenton (SPF) treatment along with the generation of oxalic acid as an ultimate product of degradation and COS increase. Different samples of real textile wastewater were treated in order to validate optimized treatment condition with regard to wastewater variability. Results showed median organic carbon removal near 90 %. Finally, reuse of treated textile wastewater in both dyeing and washing stages of production was successful. These results confirm that solar photo-Fenton, as a single treatment, enables wastewater reclamation in the textile industry. Graphical abstract Solar photo-Fenton as a revolutionary treatment technology for "closing-the-loop" in the textile industry.

  6. In Vivo Lighted Fluorescence via Fenton Reaction: Approach for Imaging of Hydrogen Peroxide in Living Systems.

    Science.gov (United States)

    Liu, Changhui; Chen, Weiju; Qing, Zhihe; Zheng, Jing; Xiao, Yue; Yang, Sheng; Wang, Lili; Li, Yinhui; Yang, Ronghua

    2016-04-05

    By virtue of its high sensitivity and rapidity, Fenton reaction has been demonstrated as a powerful tool for in vitro biochemical analysis; however, in vivo applications of Fenton reaction still remain to be exploited. Herein, we report, for the first time, the design, formation and testing of Fenton reaction for in vivo fluorescence imaging of hydrogen peroxide (H2O2). To realize in vivo fluorescence imaging of H2O2 via Fenton reaction, a functional nanosphere, Fc@MSN-FDNA/PTAD, is fabricated from mesoporous silica nanoparticle (MSN), a Fenton reagent of ferrocene (Fc), ROX-labeled DNA (FDNA), and a cationic perylene derivative (PTAD). The ferrocene molecules are locked in the pore entrances of MSN, and exterior of MSN is covalently immobilized with FDNA. As a key part, PTAD acts as not only the gatekeeper of MSN but also the efficient quencher of ROX. H2O2 can permeate into the nanosphere and react with ferrocene to product hydroxyl radical (·OH) via Fenton reaction, which cleaves FDNA to detach ROX from PTAD, thus in turn, lights the ROX fluorescence. Under physiological condition, H2O2 can be determined from 5.0 nM to 1.0 μM with a detection limit of 2.4 nM. Because of the rapid kinetics of Fenton reaction and high specificity for H2O2, the proposed method meets the requirement for real applications. The feasibility of Fc@MSN-FDNA/PTAD for in vivo applications is demonstrated for fluorescence imaging of exogenous and endogenous H2O2 in cells and mice. We expect that this work will not only contribute to the H2O2-releated studies but also open up a new way to exploit in vivo Fenton reaction for biochemical research.

  7. POLYNUCLEAR AROMATIC HYDROCARBON (PAH) RELEASE FROM SOIL DURING TREATMENT WITH FENTON'S REAGENT

    Science.gov (United States)

    Fenton's Reagent was used to treat soil from a wood-treating site in southeastern Ohio which had been contaminated with creosote. Slurries, consisting of 10 µg of contaminated soil and 30 mL water were treated with 40 mL of Fenton's Reagent (1:1 of 30% H2O2 ...

  8. Decolorization kinetics of Procion H-exl dyes from textile dyeing using Fenton-like reactions

    Energy Technology Data Exchange (ETDEWEB)

    Ntampegliotis, K. [Department of Physical Sciences, Technological and Educational Institute of Larisa, T.K 411 10 Larisa (Greece); Riga, A. [Department of Physical Sciences, Technological and Educational Institute of Larisa, T.K 411 10 Larisa (Greece); Karayannis, V. [Department of Physical Sciences, Technological and Educational Institute of Larisa, T.K 411 10 Larisa (Greece); Bontozoglou, V. [Department of Mechanical and Industrial Engineering, University of Thessaly, Pedion Areos, T.K 383 34 Volos (Greece); Papapolymerou, G. [Department of Physical Sciences, Technological and Educational Institute of Larisa, T.K 411 10 Larisa (Greece)]. E-mail: papapoly@teilar.gr

    2006-08-10

    The decolorization kinetics of three commercially used Procion H-exl dyes was studied using a Fenton-like reagent. The effect of the major system parameters (pH, concentration of H{sub 2}O{sub 2} and Fe{sup 3+} and initial dye concentration) on the kinetics was determined. For comparison, the effect of the use of UV irradiated Fenton-like reagent and of Fenton reagent on the kinetics was also examined. In addition, mineralization rates and the biodegradability improvement as well as the effect of the addition of Cl{sup -}, CO{sub 3} {sup 2-} or HCO{sub 3} {sup -} on the decolorization rates was studied. The reactions were carried out in a 300 ml stirred cylindrical reactor with the capability of UV irradiation. The dye half-life time goes through a minimum with respect to the solution pH between 3 and 4. It also exhibits a broad minimum with respect to Fe{sup 3+} and H{sub 2}O{sub 2} at molar ratios of H{sub 2}O{sub 2}/Fe{sup 3+} from about 100 to 10. The addition of CO{sub 3} {sup 2-} and HCO{sub 3} {sup -} substantially reduces the decolorization rates, while this effect is significantly less pronounced with Cl{sup -}. At an optimum range of parameters, the mineralization rate (TOC reduction) is very slow for the Fenton-like process (TOC decrease from an initial 49.5 to 41.1 mg/l after 30 min and to only 35.2 mg/l after 600 min), but it increases significantly for the photo-Fenton-like process (to TOC values of 39.7 and 11.4 mg/l, respectively). The biodegradability, as expressed by the BOD/COD ratio, increases significantly from an initial value of 0.11-0.55 for the Fenton-like and to 0.72 for the photo-Fenton-like processes.

  9. Decolorization kinetics of Procion H-exl dyes from textile dyeing using Fenton-like reactions.

    Science.gov (United States)

    Ntampegliotis, K; Riga, A; Karayannis, V; Bontozoglou, V; Papapolymerou, G

    2006-08-10

    The decolorization kinetics of three commercially used Procion H-exl dyes was studied using a Fenton-like reagent. The effect of the major system parameters (pH, concentration of H(2)O(2) and Fe(3+) and initial dye concentration) on the kinetics was determined. For comparison, the effect of the use of UV irradiated Fenton-like reagent and of Fenton reagent on the kinetics was also examined. In addition, mineralization rates and the biodegradability improvement as well as the effect of the addition of Cl(-), CO(3)(2-) or HCO(3)(-) on the decolorization rates was studied. The reactions were carried out in a 300 ml stirred cylindrical reactor with the capability of UV irradiation. The dye half-life time goes through a minimum with respect to the solution pH between 3 and 4. It also exhibits a broad minimum with respect to Fe(3+) and H(2)O(2) at molar ratios of H(2)O(2)/Fe(3+) from about 100 to 10. The addition of CO(3)(2-) and HCO(3)(-) substantially reduces the decolorization rates, while this effect is significantly less pronounced with Cl(-). At an optimum range of parameters, the mineralization rate (TOC reduction) is very slow for the Fenton-like process (TOC decrease from an initial 49.5 to 41.1 mg/l after 30 min and to only 35.2 mg/l after 600 min), but it increases significantly for the photo-Fenton-like process (to TOC values of 39.7 and 11.4 mg/l, respectively). The biodegradability, as expressed by the BOD/COD ratio, increases significantly from an initial value of 0.11-0.55 for the Fenton-like and to 0.72 for the photo-Fenton-like processes.

  10. Magnetic minerals from volcanic Ultisols as heterogeneous Fenton catalysts

    International Nuclear Information System (INIS)

    Aravena, S.; Pizarro, C.; Rubio, M. A.; Cavalcante, L. C. D.; Garg, V. K.; Pereira, M. C.; Fabris, J. D.

    2010-01-01

    This study was devoted to the evaluation of the effectiveness of Fenton catalysts, based on magnetically-concentrated portions of iron oxide-rich sand fractions from two magnetic Ultisols, derived from volcanic materials of southern Chile. The samples were labeled according to the municipality where the sample sites are geographically located, namely Metrenco and Collipulli, and were characterized with Moessbauer spectroscopy at 298 K and saturation magnetization (σ) measurements. Moessbauer data revealed a complex magnetic hyperfine structure for these magnetic portions from both soil-sand materials, suggesting relatively complex mineral assemblages. The monitored rate of H 2 O 2 decomposition via heterogeneous Fenton reaction revealed that materials from the Collipulli soil are more efficient Fenton catalyst than are those from the Metrenco soil. The reasons for these differences are from now on being explored on basis of a more detailed chemical investigation of these samples.

  11. Oxidation of microcystin-LR by the Fenton process : Kinetics, degradation intermediates, water quality and toxicity assessment

    NARCIS (Netherlands)

    Park, Jeong-Ann; Yang, Boram; Park, Chanhyuk; Choi, Jae-Woo; van Genuchten, Case M.|info:eu-repo/dai/nl/413489647; Lee, Sang-Hyup

    2017-01-01

    The Fenton process was assessed as a cost-effective technology for the removal of Microcystin-LR (MC-LR) among UV, UV/H2O2, and Fenton process according to efficiency and electrical energy per order (EE/O). The determined practical concentrations of the Fenton reagents were 5 mg/L Fe(II) and 5 mg/L

  12. Pd-catalytic in situ generation of H2O2 from H2 and O2 produced by water electrolysis for the efficient electro-fenton degradation of rhodamine B.

    Science.gov (United States)

    Yuan, Songhu; Fan, Ye; Zhang, Yucheng; Tong, Man; Liao, Peng

    2011-10-01

    A novel electro-Fenton process was developed for wastewater treatment using a modified divided electrolytic system in which H2O2 was generated in situ from electro-generated H2 and O2 in the presence of Pd/C catalyst. Appropriate pH conditions were obtained by the excessive H+ produced at the anode. The performance of the novel process was assessed by Rhodamine B (RhB) degradation in an aqueous solution. Experimental results showed that the accumulation of H2O2 occurred when the pH decreased and time elapsed. The maximum concentration of H2O2 reached 53.1 mg/L within 120 min at pH 2 and a current of 100 mA. Upon the formation of the Fenton reagent by the addition of Fe2+, RhB degraded completely within 30 min at pH 2 with a pseudo first order rate constant of 0.109 ± 0.009 min(-1). An insignificant decline in H2O2 generation and RhB degradation was found after six repetitions. RhB degradation was achieved by the chemisorption of H2O2 on the Pd/C surface, which subsequently decomposed into •OH upon catalysis by Pd0 and Fe2+. The catalytic decomposition of H2O2 to •OH by Fe2+ was more powerful than that by Pd0, which was responsible for the high efficiency of this novel electro-Fenton process.

  13. Treatment of Oily Wastewater by the Optimization of Fe2O3 Calcination Temperatures in Innovative Bio-Electron-Fenton Microbial Fuel Cells

    Directory of Open Access Journals (Sweden)

    Jung-Chen Wu

    2018-03-01

    Full Text Available Due to the fact that Iron oxide (Fe2O3 is known to have a good effect on the photochemical reaction of catalysts, an investigation in this study into the enhancement of the degradation performance of bio-electro-Fenton microbial fuel cells (Bio-E-Fenton MFCs was carried out using three photocatalytic cathodes. These cathodes were produced at different calcination temperatures of Fe2O3 ranging from 500 °C to 900 °C for realizing their performance as photo catalysts within the cathodic chamber of an MFC, and they were compared for their ability to degrade oily wastewater. Results show that a suitable temperature for the calcination of iron oxide would have a significantly positive effect on the performance of Bio-E-Fenton MFCs. An optimal calcination temperature of 500 °C for Fe2O3 in the electrode material of the cathode was observed to produce a maximum power density of 52.5 mW/m2 and a chemical oxygen demand (COD degradation rate of oily wastewater (catholyte of 99.3% within one hour of operation. These novel findings will be useful for the improvement of the performance and applications of Bio-E-Fenton MFCs and their future applications in the field of wastewater treatment.

  14. Iron crystallization in a fluidized-bed Fenton process.

    Science.gov (United States)

    Boonrattanakij, Nonglak; Lu, Ming-Chun; Anotai, Jin

    2011-05-01

    The mechanisms of iron precipitation and crystallization in a fluidized-bed reactor were investigated. Within the typical Fenton's reagent dosage and pH range, ferric ions as a product from ferrous ion oxidation would be supersaturated and would subsequently precipitate out in the form of ferric hydroxide after the initiation of the Fenton reaction. These precipitates would simultaneously crystallize onto solid particles in a fluidized-bed Fenton reactor if the precipitation proceeded toward heterogeneous nucleation. The heterogeneous crystallization rate was controlled by the fluidized material type and the aging/ripening period of the crystallites. Iron crystallization onto the construction sand was faster than onto SiO(2), although the iron removal efficiencies at 180 min, which was principally controlled by iron hydroxide solubility, were comparable. To achieve a high iron removal rate, fluidized materials have to be present at the beginning of the Fenton reaction. Organic intermediates that can form ferro-complexes, particularly volatile fatty acids, can significantly increase ferric ion solubility, hence reducing the crystallization performance. Therefore, the fluidized-bed Fenton process will achieve exceptional performance with respect to both organic pollutant removal and iron removal if it is operated with the goal of complete mineralization. Crystallized iron on the fluidized media could slightly retard the successive crystallization rate; thus, it is necessary to continuously replace a portion of the iron-coated bed with fresh media to maintain iron removal performance. The iron-coated construction sand also had a catalytic property, though was less than those of commercial goethite. Copyright © 2011 Elsevier Ltd. All rights reserved.

  15. Environmental application of millimetre-scale sponge iron (s-Fe{sup 0}) particles (IV): New insights into visible light photo-Fenton-like process with optimum dosage of H{sub 2}O{sub 2} and RhB photosensitizers

    Energy Technology Data Exchange (ETDEWEB)

    Ju, Yongming, E-mail: juyongming@scies.org [South China Institute of Environmental Sciences, Ministry of Environmental Protection (MEP), Guangzhou 510655 (China); Innovative Laboratory for Environmental Functional Materials and Environmental Applications of Microwave Irradiation, South China Subcenter of State Environmental Dioxin Monitoring Center, Guangzhou 510655 (China); Guangdong Key Laboratory of Agro-Environment Integrated Control, South China Institute of Environmental Sciences, Guangzhou 510655 (China); Yu, Yunjiang, E-mail: yuyunjiang@scies.org [South China Institute of Environmental Sciences, Ministry of Environmental Protection (MEP), Guangzhou 510655 (China); Wang, Xiaoyan; Xiang, Mingdeng; Li, Liangzhong [South China Institute of Environmental Sciences, Ministry of Environmental Protection (MEP), Guangzhou 510655 (China); Deng, Dongyang [South China Institute of Environmental Sciences, Ministry of Environmental Protection (MEP), Guangzhou 510655 (China); Innovative Laboratory for Environmental Functional Materials and Environmental Applications of Microwave Irradiation, South China Subcenter of State Environmental Dioxin Monitoring Center, Guangzhou 510655 (China); Guangdong Key Laboratory of Agro-Environment Integrated Control, South China Institute of Environmental Sciences, Guangzhou 510655 (China); Dionysiou, Dionysios D., E-mail: dionysios.d.dionysiou@uc.edu [Environmental Engineering and Science Program, Department of Biomedical, Chemical and Environmental Engineering (DBCEE), University of Cincinnati, Cincinnati, Ohio, 45221-0012 (United States)

    2017-02-05

    Highlights: • Synergistic action of Rhodamine B (RhB), visible light, H{sub 2}O{sub 2} and s-Fe{sup 0} is essential. • The complexes of RhB and Fe{sup 3+} eject one electron via ligand-to-metal charge-transfer. • RhB assists the photo-Fenton-like removal of tetrabromobisphenol A (TBBPA). - Abstract: In this study, we firstly develop the photo-Fenton-like system with millimetric sponge iron (s-Fe{sup 0}), H{sub 2}O{sub 2}, visible light (vis, λ ≥ 420 nm) and rhodamine B (RhB), and present a comprehensive study concerning the mechanism. Thus, we investigate (1) the adsorption of RhB onto s-Fe{sup 0}, (2) the photo-Fenton-like removal of RhB over iron oxides generated from the corrosion of s-Fe{sup 0}, (3) the homogeneous photo-Fenton removal of RhB over Fe{sup 2+} or Fe{sup 3+}, (4) the Fe{sup 3+}-RhB complexes, and (5) the photo-Fenton-like removal of tetrabromobisphenol A (TBBPA). The results show that neither the adsorption process over s-Fe{sup 0} nor the photo-Fenton-like process over FeOOH, Fe{sub 3}O{sub 4} and Fe{sub 2}O{sub 3}, achieved efficient removal of RhB. For comparison, in homogeneous photo-Fenton process, the presence of Fe{sup 3+} ions, rather than Fe{sup 2+} ions, effectively eliminated RhB. Furthermore, the UV–vis spectra showing new absorbance at ∼ 285 nm indicate the complexes of RhB and Fe{sup 3+} ions, adopting vis photons to form excited state and further eject one electron via ligand-to-metal charge-transfer to activate H{sub 2}O{sub 2}. Additionally, efficient TBBPA removal was obtained only in the presence of RhB. Accordingly, the s-Fe{sup 0}– based photo-Fenton-like process assisted with dyestuff wastewater is promising for removing a series of persistent organic pollutants.

  16. Reuse of recalcitrant-rich anaerobic effluent as dilution water after enhancement of biodegradability by Fenton processes.

    Science.gov (United States)

    Arimi, Milton M; Zhang, Yongjun; Namango, Saul S; Geißen, Sven-Uwe

    2016-03-01

    Anaerobic digestion is used to treat effluents with a lot of organics, such as molasses distillery wastewater (MDW) which is the effluent of bioethanol production from molasses. The raw MDW requires a lot of dilution water before biodigestion, while the digested MDW has high level of recalcitrants which are problematic for its discharge. This study investigated ferric coagulation, Fenton, Fenton-like (with ferric ions as catalyst) processes and their combinations on the biodegradability of digested MDW. The Fenton and Fenton-like processes after coagulation increased the MDW biodegradability defined by (BOD5/COD) from 0.07 to (0.4-0.6) and saved 50% of H2O2 consumed in the classic Fenton process. The effluent from coagulation coupled to a Fenton-like process was used as dilution water for the raw MDW before the anaerobic digestion. The process was stable with volumetric loading of approx. 2.7 g COD/L/d. It resulted in increased overall biogas recovery and significantly decreased the demand for the dilution water. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Sustaining 1,2-Dichloroethane Degradation in Nanoscale Zero-Valent Iron induced Fenton system by using Sequential H2O2 Addition at Natural pH

    Science.gov (United States)

    Phenrat, T.; Le, T. S. T.

    2017-12-01

    1,2-Dichloroethane (1,2-DCA) is a prevalent subsurface contaminant found in groundwater and soil around the world. Nanoscale zero-valent iron (NZVI) is a promising in situ remediation agent for chlorinated organics. Nevertheless, 1,2-DCA is recalcitrant to reductive dechlorination using NZVI. Chemical oxidation using Fenton's reaction with conventional Fe2+ is a valid option for 1,2-DCA remediation with a major technical challenge, i.e. aquifer acidification is needed to maintain Fe2+ for catalytic reaction. In this work, NZVI Fenton's process at neutral pH was applied to degrade 1,2-DCA at high concentration (2,000 mg/L) representing dissolved 1,2-DCA concentration close to non-aqueous phase liquid source zone. Instead of using acidification to maintain dissolved Fe2+ concentration, NZVI Fenton's process is self-catalytic based on oxidative dissolution of NZVI in the present of H2O2. Interfacial H+ is produced at NZVI surface to provide appropriate local pH which continuously releases Fe2+ for Fenton's reaction. Approximately, 87% of 1,2-DCA was degraded at neutral pH with the pseudo first-order rate constant of 0.98 hour-1 using 10 g/L of NZVI and 200 mM of H2O2. However, the reaction was prohibited quickly within 3 hours presumably due to the rapid depletion of H2O2. The application of sequential H2O2 addition provided a better approach to prevent rapid inhibition via controlling the H2O2 concentration in the system to be sufficient but not excess, thus resulting in the higher degradation efficiency (the pseudo first-order rate constant of 0.49 hour-1 and 99 % degradation in 8 hours). Using NZVI with sequential H2O2 addition was also successful in degrading 1,2-DCA sorbed on to soil, yielding 99% removal of 1,2-DCA within 16 hours at the rate constant of 0.23 hour-1, around two times slower than in the system without soil presumably due to rate-limited 1,2-DCA desorption from soil. Mechanistic understanding of how sequential addition of H2O2, in comparison to

  18. Treating leachate with advanced oxidation: applying Fenton's reagent; Oxidaciones avanzadas para el tratamiento de lixiviado: aplicacion del Reactivo de Fenton

    Energy Technology Data Exchange (ETDEWEB)

    Maranonn Ruiz, I.; Sancho Seuma, L.

    2003-07-01

    The present study investigates the removal of refractory organics by Advanced Oxidation Process: Fenton's Reaction. A batch test protocol was designed to study the oxidation and coagulation in Fenton Reaction. The batch tests were conducted to determine the optimum conditions for the plant operation such as pH, H{sub 2}O{sub 2} dosage, FeSO{sub 4} dosage and contact time. It was found that the highest removal efficiencies of COD were with the oxidation at acid pH around 3 and the coagulation at basic pH around 8, few minutes of treatment time, the initial concentrations of H{sub 2}O{sub 2} were in the range 68-1550 mg/l and the different dosages of FeSO{sub 4} were in the range 487-3038 mg/l. They were added in determinate proportions to get the highest efficiency of producing OH, DBO{sub 5}/DQO ratio was decreased from 0,3 to 0,1. Therefore Fenton's reaction process is a very effective means for a pretreatment or tertiary treatment of biological methods. (Author) 20 refs.

  19. A Comparative Analysis of 2-(Thiocyanomethylthio-Benzothiazole Degradation Using Electro-Fenton and Anodic Oxidation on a Boron-Doped Diamond Electrode

    Directory of Open Access Journals (Sweden)

    Armando Vázquez

    2018-01-01

    Full Text Available 2-(Thiocyanomethylthio-benzothiazole (TCMTB is used as fungicide in the paper, tannery, paint, and coatings industries, and its study is important as it is considered toxic to aquatic life. In this study, a comparison of direct anodic oxidation (AO using a boron-doped diamond electrode (BDD and electro-Fenton (EF processes for TCMTB degradation in acidic chloride and sulfate media using a FM01-LC reactor was performed. The results of the electrolysis processes studied in the FM01-LC reactor showed a higher degradation of TCMTB with the anodic oxidation process than with the electro-Fenton process, reaching 81% degradation for the former process versus 47% degradation for the latter process. This difference was attributed to the decrease in H2O2 during the EF process, due to parallel oxidation of chlorides. The degradation rate and current efficiency increased as a function of volumetric flow rate, indicating that convection promotes anodic oxidation and electro-Fenton processes. The results showed that both AO and EF processes could be useful strategies for TCMTB toxicity reduction in wastewaters.

  20. Design of a neutral three-dimensional electro-Fenton system with foam nickel as particle electrodes for wastewater treatment

    International Nuclear Information System (INIS)

    Liu, Wei; Ai, Zhihui; Zhang, Lizhi

    2012-01-01

    Highlights: ► Remove RhB by a novel 3D-E-Fenton system using foam nickel as particle electrodes. ► The 3D-E-Fenton system exhibit much higher RhB removal efficiency than the counterpart 3D-E and E-Fenton system. ► Foam nickel as a particle electrode displays good oxygen reduction activity. ► The performance of RhB removal was optimized by some operating parameters and the optimization pH was the neutral. - Abstract: In this work, we demonstrate a novel three-dimensional electro-Fenton system (3D-E-Fenton) for wastewater treatment with foam nickel, activated carbon fiber and Ti/RuO 2 –IrO 2 as the particle electrodes, the cathode, and the anode respectively. This 3D-E-Fenton system could exhibit much higher rhodamine B removal efficiency (99%) than the counterpart three-dimensional electrochemical system (33%) and E-Fenton system (19%) at neutral pH in 30 min. The degradation efficiency enhancement was attributed to much more hydroxyl radicals generated in the 3D-E-Fenton system because foam nickel particle electrodes could activate molecular oxygen to produce ·O 2 − via a single-electron transfer pathway to subsequently generate more H 2 O 2 and hydroxyl radicals. This is the first observation of molecular oxygen activation over the particle electrodes in the three-dimensional electrochemical system. These interesting findings could provide some new insight on the development of high efficient E-Fenton system for wastewater treatment at neutral pH.

  1. Degradation of black liquor from bioethanol process using coagulation and Fenton-like methods

    Science.gov (United States)

    Muryanto, Muryanto; Sari, Ajeng Arum; Abimanyu, Haznan

    2017-01-01

    Black liquor is one of the main by-products of the pretreatment process in bioethanol production from oil palm empty fruit bunches. Black liquor wastewater releases black coloured effluent with high chemical oxygen demand (COD) and low dissolved oxygen (DO). It had a distinctive dark coloration, high alkalinity (pH=13), high organic content (COD > 50,000 ppm) and a high solid content (TSS > 5,000 ppm). Lignin destruction can be done by using high oxidation from OH radical system such as advanced oxidation processes (AOPs). Thereafter, the high concentration of COD, color, and TSS can be removed. The general aim of the present investigation was to determine degradation of black liquor wastewater by using a combined coagulation and Fenton-like methods. In this research, we use Poly Aluminum Chloride (PAC) as a coagulant and FeCl3.6H2O and H2O2 for Fenton-like's reagent. The process was conducted in jar test at 200 rpm for 30 minutes and after that slowly mixed for 2 hours and left for sedimentation 24 hours. 50 ml black liquor was added with variation dose of 1-5% PAC, and 10 % Fenton-like reagent. Hydroxyl radical was generated by the Fenton-like's reagent (ratio FeCl3.6H2O : H2O2 was varied). The highest decolorization of black liquor 70 % was obtained under 5% PAC coagulant. The pH of the wastewater was reduced from 13.00 to 8.07 after the addition of the coagulant. The decolorization of original black liquor was approximately 58% through the Fenton-like process. The combination of PAC and Fenton-like reagent has able to enhance the decolorization of black liquor up to 97%.

  2. Abatement of phenolic mixtures by catalytic wet oxidation enhanced by Fenton's pretreatment: Effect of H2O2 dosage and temperature

    International Nuclear Information System (INIS)

    Santos, A.; Yustos, P.; Rodriguez, S.; Simon, E.; Garcia-Ochoa, F.

    2007-01-01

    Catalytic wet oxidation (CWO) of a phenolic mixture containing phenol, o-cresol and p-cresol (500 mg/L on each pollutant) has been carried out using a commercial activated carbon (AC) as catalyst, placed in a continuous three-phase reactor. Total pressure was 16 bar and temperature was 127 deg. C. Pollutant conversion, mineralization, intermediate distribution, and toxicity were measured at the reactor outlet. Under these conditions no detoxification of the inlet effluent was found even at the highest catalyst weight (W) to liquid flow rate (Q L ) ratio used. On the other hand, some Fenton Runs (FR) have been carried out in a batch way using the same phenolic aqueous mixture previously cited. The concentration of Fe 2+ was set to 10 mg/L. The influence of the H 2 O 2 amount (between 10 and 100% of the stoichiometric dose) and temperature (30, 50, and 70 deg. C) on phenols conversion, mineralization, and detoxification have been analyzed. Phenols conversion was near unity at low hydrogen peroxide dosage but mineralization and detoxification achieved an asymptotic value at each temperature conditions. The integration of Fenton reagent as pretreatment of the CWO process remarkably improves the efficiency of the CWO reactor and allows to obtain detoxified effluents at mild temperature conditions and relatively low W/Q L values. For a given phenolic mixture a temperature range of 30-50 deg. C in the Fenton pretreatment with a H 2 O 2 dosage between 20 and 40% of the stoichiometric amount required can be proposed

  3. Pretreatment of lignocellulosic biomass using Fenton chemistry

    Science.gov (United States)

    Pretreatment is a necessary step in “biomass to biofuel conversion” due to the recalcitrant nature of lignocellulosic biomass. White-rot fungi utilize peroxidases and hydrogen peroxide (in vivo Fenton chemistry) to degrade lignin. In an attempt to mimic this process, solution phase Fenton chemistry ...

  4. Sono-photo-Fenton oxidation of bisphenol-A over a LaFeO3 perovskite catalyst.

    Science.gov (United States)

    Dükkancı, Meral

    2018-01-01

    In this study, oxidation of bisphenol-A (IUPAC name - 2,2-(4,4-dihydroxyphenyl, BPA), which is an endocrine disrupting phenolic compound used in the polycarbonate plastic and epoxy resin industry, was investigated using sono-photo-Fenton process under visible light irradiation in the presence of an iron containing perovskite catalyst, LaFeO 3 . The catalyst prepared by sol-gel method, calcined at 500°C showed a catalytic activity in BPA oxidation using sono-photo-Fenton process with a degradation degree and a chemical oxygen demand (COD) reduction of 21.8% and 11.2%, respectively. Degradation of BPA was studied by using individual and combined advanced oxidation techniques including sonication, heterogeneous Fenton reaction and photo oxidation over this catalyst to understand the effect of each process on degradation of BPA. It was seen, the role of sonication was very important in hybrid sono-photo-Fenton process due to the pyrolysis and sonoluminescence effects caused by ultrasonic irradiation. The prepared LaFeO 3 perovskite catalyst was a good sonocatalyst rather than a photocatalyst. Sonication was not only the effective process to degrade BPA but also it was the cost effective process in terms of energy consumption. The studies show that the energy consumption is lower in the sono-Fenton process than those in the photo-Fenton and sono-photo- Fenton processes. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Electrochemical treatment of Acid Red 1 by electro-Fenton and photoelectro-Fenton processes

    Directory of Open Access Journals (Sweden)

    Camilo González-Vargas

    2014-12-01

    Full Text Available Small volumes (100 mL of acidic aqueous solutions with 30-200 mg L-1 TOC of the toxic azo dye Acid Red 1 (AR1 have been comparatively treated by various electrochemical advanced oxidation processes (EAOPs. The electrolytic system consisted of a BDD anode able to produce ·OH and an air-diffusion cathode that generated H2O2, which subsequently reacted with added Fe2+ to yield additional ·OH from Fenton’s reaction. Under optimized conditions (i.e., 1.0 mM Fe2+, 60 mA cm-2, pH 3.0, 35 ºC, the analysis of the initial rates for decolourization and AR1 decay assuming a pseudo-first-order kinetics revealed a much higher rate constant for photoelectro-Fenton (PEF, ~ 2.7x10-3 s-1 compared to electro-Fenton (EF, ~ 0.6x10-3 s-1. Mineralization after 180 min was also greater in the former treatment (90 % vs 63 %. The use of UV radiation in PEF contributed to Fe(III photoreduction as well as to photodecarboxylation of refractory intermediates, yielding a mineralization current efficiency as high as 85% during the treatment of solutions of 200 mg L-1 TOC. Primary reaction intermediates included three aromatic derivatives with the initial naphthalenic structure and four molecules only featuring benzenic rings, which were totally mineralized in PEF. 

  6. Sulfamethoxazole abatement by photo-Fenton

    International Nuclear Information System (INIS)

    Gonzalez, Oscar; Sans, Carme; Esplugas, Santiago

    2007-01-01

    The objective of this work was to study the abatement of 200 mg L -1 sulfamethoxazole (SMX) solution by means of photo-Fenton process. Biodegradability of the treated solutions was followed by the ratio biochemical oxygen demand at five days/chemical oxygen demand (BOD 5 /COD) and toxicity by Microtox[reg] and inhibition tests. Experiments with different initial concentration of H 2 O 2 were carried out. The initial amount of Fe 2+ and pH of the solution were set at 10 mg L -1 and 2.8 respectively. The temperature of the reactor was kept constant in all the experiments (25 ± 0.8 deg. C). Photo-Fenton process is thought to be a successful treatment step to improve the biodegradability of wastewater containing SMX. The complete antibiotic removal was achieved for a H 2 O 2 dose over 300 mg L -1 . Biodegradability (BOD 5 /COD) rose from zero (SMX solution) to values higher than 0.3 (treated solutions). Toxicity and inhibition tests pointed out in the same direction: oxidized intermediates for initial H 2 O 2 dose over 300 mg L -1 showed no toxicity effects on pure bacteria and no inhibition on activated sludge activity

  7. Characterization of changes in floc morphology, extracellular polymeric substances and heavy metals speciation of anaerobically digested biosolid under treatment with a novel chelated-Fe2+ catalyzed Fenton process.

    Science.gov (United States)

    He, Juanjuan; Yang, Peng; Zhang, Weijun; Cao, Bingdi; Xia, Hua; Luo, Xi; Wang, Dongsheng

    2017-11-01

    A novel chelated-Fe 2+ catalyzed Fenton process (CCFP) was developed to enhance dewatering performance of anaerobically digested biosolid, and changes in floc morphology, extracellular polymeric substances (EPS) and heavy metals speciation were also investigated. The results showed that addition of chelating agents caused EPS solubilization by binding multivalent cations. Like traditional Fenton, CCFP performed well in improving anaerobically digested sludge dewatering property. The highly active radicals (OH, O 2 - ) produced in classical Fenton and CCFP were responsible for sludge flocs destruction and consequently degradation of biopolymers into small molecules. Furthermore, more plentiful pores and channels were presented in cake after Fenton treatment, which was conducive to water drainage under mechanical compression. Additionally, a portion of active heavy metals in the form of oxidizable and reducible states were dissolved under CCFP. Therefore, CCFP could greatly simplify the operating procedure of Fenton conditioning and improve its process adaptability for harmless treatment of biological sludge. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Efficient treatment of an electroplating wastewater containing heavy metal ions, cyanide, and organics by H2O2 oxidation followed by the anodic Fenton process.

    Science.gov (United States)

    Zhao, Xu; Wang, Haidong; Chen, Fayuan; Mao, Ran; Liu, Huijuan; Qu, Jiuhui

    2013-01-01

    A real electroplating wastewater, containing heavy metals, cyanide, and organic contaminants, was treated by electrocoagulation (EC), H2O2 oxidation, H2O2 pre-oxidation followed by EC, and the anodic Fenton process and the efficacy of the processes was compared. Concentration of cyanide, Cu, Ni, Zn, and Cr was largely decreased by EC within 5 min. When the reaction time was extended, removal of residual cyanide, Cu, and Ni was limited. In H2O2 oxidation, the concentration of cyanide decreased from initial 75 to 12 mg L(-1) in 30 min. The effluents from the H2O2 oxidation were further treated by EC or anodic Fenton. In EC, the concentration of total cyanide, Ni, and Cu decreased to below 0.3, 0.5, and 1.5 mg L(-1), respectively. Removal efficiency of chemical oxygen demand by EC was less than 20.0%. By contrast, there was 73.5% reduction by the anodic Fenton process with 5 mM H2O2 at 30 min; this can be attributed to the oxidation induced by hydroxyl radicals generated by the reaction of H2O2 with the electrogenerated Fe(2+). Meanwhile, residual cyanide, Cu, and Ni can also be efficiently removed. Transformation of organic components in various processes was analyzed using UV-visible and fluorescence excitation-emission spectra.

  9. PREDICTING FENTON-DRIVEN DEGRADATION USING CONTAMINANT ANALOG

    Science.gov (United States)

    The reaction of hydrogen peroxide (H2O2) and Fe(II) (Fenton's reaction) generates hydroxyl radicals (OH) that can be used to oxidize contaminants in soils and aquifers. In such environments, insufficient iron, reactions involving H2O2 that do not yield OH, and OH reactions with ...

  10. Structural Characterization of the Foliated-Layered Gabbro Transition in Wadi Tayin of the Samail Ophiolite, Oman; Oman Drilling Project Holes GT1A and GT2A

    Science.gov (United States)

    Deans, J. R.; Crispini, L.; Cheadle, M. J.; Harris, M.; Kelemen, P. B.; Teagle, D. A. H.; Matter, J. M.; Takazawa, E.; Coggon, J. A.

    2017-12-01

    Oman Drilling Project Holes GT1A and GT2A were drilled into the Wadi Tayin massif, Samail ophiolite and both recovered ca. 400 m of continuous core through a section of the layered gabbros and the foliated-layered gabbro transition. Hole GT1A is cut by a discrete fault system including localized thin ultracataclastic fault zones. Hole GT2A is cut by a wider zone of brittle deformation and incipient brecciation. Here we report the structural history of the gabbros reflecting formation at the ridge to later obduction. Magmatic and high temperature history- 1) Both cores exhibit a pervasive, commonly well-defined magmatic foliation delineated by plagioclase, olivine and in places clinopyroxene. Minor magmatic deformation is present. 2) The dip of the magmatic foliation varies cyclically, gradually changing dip by 30o from gentle to moderate over a 50 m wavelength. 3) Layering is present throughout both cores, is defined by changes in mode and grain size ranging in thickness from 2 cm to 3 m and is commonly sub-parallel to the foliation. 4) There are no high temperature crystal-plastic shear zones in the core. Key observations include: no simple, systematic shallowing of dip with depth across the foliated-layered gabbro transition and layering is continuous across this transition. Cyclic variation of magmatic foliation dip most likely reflects the process of plate separation at the ridge axis. Near-axis faulting- i) On or near-axis structures consist of epidote-amphibole bearing hydraulic breccias and some zones of intense cataclasis with intensely deformed epidote and seams of clay and chlorite accompanied by syntectonic alteration of the wall rock. Early veins are filled with amphibole, chlorite, epidote, and anhydrite. ii) The deformation ranges from brittle-ductile, causing local deflection of the magmatic foliation, to brittle offset of the foliation and core and mantle structures in anhydrite veins. iii) The prevalent sense of shear is normal and slickenfibers

  11. The enhanced catalytic degradation of SiO{sub 2}/Fe{sub 3}O{sub 4}/C@TiO{sub 2} photo-Fenton system on p-nitrophenol

    Energy Technology Data Exchange (ETDEWEB)

    Hou, Yanhui; Wang, Yechen; Yuan, Huili; Chen, Hang; Chen, Guowei; Shen, Junhai; Li, Liangchao, E-mail: sky52@zjnu.cn [Zhejiang Normal University, Key Laboratory of the Ministry of Education for Advanced Catalysis Materials, Department of Chemistry (China)

    2016-11-15

    Heterogeneous photo-Fenton SiO{sub 2}/Fe{sub 3}O{sub 4}/C@TiO{sub 2} (SFCT) catalyst with a core-multishell structure and a diameter of about 550 nm was successfully prepared and was characterized by scanning electron microscopy (SEM), TEM, XRD, Raman, and Fourier transform infrared (FT-IR). The results illustrated that anatase TiO{sub 2} coexisted with rutile TiO{sub 2}, in which the anatase phase was the main crystal phase. In addition, the catalytic activity of SFCT catalyst had been evaluated in the catalytic degradation on p-nitrophenol (PNP). The influence factors on the PNP degradation, including SFCT component ratio (m{sub SFC}/ m{sub TiO2}), H{sub 2}O{sub 2} dosage, solution pH, and PNP concentration, had been investigated. And the contrast experiments about the photo-Fenton catalytic mechanism revealed that the SFCT-2 catalyst possessed a superior activity in the neutral environment due to the optimal activity matching between Fe{sub 3}O{sub 4} and TiO{sub 2}, and it exhibited the stable catalytic performance after five successive recycles. Therefore, the SFCT-2 catalyst had a promising application for the photo-Fenton degradation of organic contaminant.

  12. Use of Fenton oxidation to improve the biodegradability of a pharmaceutical wastewater

    International Nuclear Information System (INIS)

    Tekin, Huseyin; Bilkay, Okan; Ataberk, Selale S.; Balta, Tolga H.; Ceribasi, I. Haluk; Sanin, F. Dilek; Dilek, Filiz B.; Yetis, Ulku

    2006-01-01

    The applicability of Fenton's oxidation to improve the biodegradability of a pharmaceutical wastewater to be treated biologically was investigated. The wastewater was originated from a factory producing a variety of pharmaceutical chemicals. Treatability studies were conducted under laboratory conditions with all chemicals (having COD varying from 900 to 7000 mg/L) produced in the factory in order to determine the operational conditions to utilize in the full-scale treatment plant. Optimum pH was determined as 3.5 and 7.0 for the first (oxidation) and second stage (coagulation) of the Fenton process, respectively. For all chemicals, COD removal efficiency was highest when the molar ratio of H 2 O 2 /Fe 2+ was 150-250. At H 2 O 2 /Fe 2+ ratio of 155, 0.3 M H 2 O 2 and 0.002 M Fe 2+ , provided 45-65% COD removal. The wastewater treatment plant that employs Fenton oxidation followed by aerobic degradation in sequencing batch reactors (SBR), built after these treatability studies provided an overall COD removal efficiency of 98%, and compliance with the discharge limits. The efficiency of the Fenton's oxidation was around 45-50% and the efficiency in the SBR system which has two reactors each having a volume of 8 m 3 and operated with a total cycle time of 1 day, was around 98%, regarding the COD removal

  13. IN-SITU FENTON OXIDATION: A CRITICAL ANALYSIS

    Science.gov (United States)

    In-situ Fenton oxidation (ISFO) is a rapidly emerging technology which involves the injection of hydrogen peroxide (H2O2) and other chemical reagents into the subsurface for the purpose of oxidizing and transforming contaminants. ISFO is being applied at an increasing number of ...

  14. Multi-color lightcurve observation of the asteroid (163249) 2002 GT

    Science.gov (United States)

    Oshima, M.; Abe, S.

    2014-07-01

    NASA's Deep Impact/EPOXI spacecraft plans to encounter the asteroid (163249) 2002 GT, classified as a PHA (Potentially Hazardous Asteroid), on January 4, 2020. However, the taxonomic type and spin state of 2002 GT remain to be determined. We have carried out ground-based multi-color (B-V-R-I) lightcurve observations taking advantage of the 2002 GT Characterization Campaign by NASA. Multi-color lightcurve measurements allow us to estimate the rotation period and obtain strong constraints on the shape and pole orientation. Here we found that the rotation period of 2002 GT is estimated to be 3.7248 ± 0.1664 h. In mid-2013, 2002 GT passed at 0.015 au from the Earth, resulting an exceptional opportunity for ground-based characterization. Using the 0.81-m telescope of the Tenagra Observatory (110°52'44.8''W, +31°27'44.4''N, 1312 m) in Arizona, USA, and the Johnson-Cousins BVRI filters, we have found lightcurves of 2002 GT (Figure). The Tenagra II 0.81-m telescope is used for research of the Hayabusa2 target Asteroid (162173) 1999 JU_3. The lightcurves (relative magnitude) show that the rotation period of 2002 GT, the target of NASA's Deep Impact/EPOXI spacecraft, is estimated to be 3.7248 ± 0.1664 hr. On June 9, 2013, we had 7 hours of ground-based observations on 2002 GT from 4:00 to 11:00 UTC. The number of comparison stars for differential photometry was 34. Because of tracking the fast-moving asteroid, it was necessary to have the same comparison star among the fields of vision. We have also obtained absolute photometry of 2002 GT on June 13, 2013.

  15. Exquisite Enzyme-Fenton Biomimetic Catalysts for Hydroxyl Radical Production by Mimicking an Enzyme Cascade.

    Science.gov (United States)

    Zhang, Qi; Chen, Shuo; Wang, Hua; Yu, Hongtao

    2018-03-14

    Hydrogen peroxide (H 2 O 2 ) is a key reactant in the Fenton process. As a byproduct of enzymatic reaction, H 2 O 2 can be obtained via catalytical oxidation of glucose using glucose oxidase in the presence of O 2 . Another oxidation product (gluconic acid) can suitably adjust the microenvironmental pH contributing to the Fe 3+ /Fe 2+ cycle in the Fenton reaction. Enzymes are extremely efficient at catalyzing a variety of reactions with high catalytic activity, substrate specificity, and yields in living organisms. Inspired by the multiple functions of natural multienzyme systems, an exquisite nanozyme-modified α-FeOOH/porous carbon (PC) biomimetic catalyst constructed by in situ growth of glucose oxidase-mimicking Au nanoparticles and crystallization of adsorbed ferric ions within carboxyl into hierarchically PC is developed as an efficient enzyme-Fenton catalyst. The products (H 2 O 2 , ∼4.07 mmol·L -1 ) of the first enzymatic reaction are immediately used as substrates for the second Fenton-like reaction to generate the valuable • OH (∼96.84 μmol·L -1 ), thus mimicking an enzyme cascade pathway. α-FeOOH nanocrystals, attached by C-O-Fe bondings, are encapsulated into the mesoporous PC frameworks, facilitating the electron transfer between α-FeOOH and the PC support and greatly suppressing iron leaching. This study paves a new avenue for designing biomimetic enzyme-based Fenton catalysts mimicking a natural system for • OH production.

  16. Development of a trickle bed reactor of electro-Fenton process for wastewater treatment

    International Nuclear Information System (INIS)

    Lei, Yangming; Liu, Hong; Shen, Zhemin; Wang, Wenhua

    2013-01-01

    Highlights: • An electrochemical trickle bed reactor was composed of C-PTFE-coated graphite chips. • The trickle bed reactor had a high H 2 O 2 production rate in a dilute electrolyte. • An azo dye was effectively decomposed by the electro-Fenton process in the reactor. -- Abstract: To avoid electrolyte leakage and gas bubbles in the electro-Fenton (E-Fenton) reactors using a gas diffusion cathode, we developed a trickle bed cathode by coating a layer composed of carbon black and polytetrafluoroethylene (C-PTFE) onto graphite chips instead of carbon cloth. The trickle bed cathode was optimized by single-factor and orthogonal experiments, in which carbon black, PTFE, and a surfactant were considered as the determinant of the performance of graphite chips. In the reactor assembled by the trickle bed cathode, H 2 O 2 was generated with a current of 0.3 A and a current efficiency of 60%. This performance was attributed to the fine distribution of electrolyte and air, as well as the effective oxygen transfer from the gas phase to the electrolyte–cathode interface. In terms of H 2 O 2 generation and current efficiency, the developed trickle bed reactor had a performance comparable to that of the conventional E-Fenton reactor using a gas diffusion cathode. Further, 123 mg L −1 of reactive brilliant red X-3B in aqueous solution was decomposed in the optimized trickle bed reactor as E-Fenton reactor. The decolorization ratio reached 97% within 20 min, and the mineralization reached 87% within 3 h

  17. Ultrasound coupled with Fenton oxidation pre-treatment of sludge to release organic carbon, nitrogen and phosphorus

    Energy Technology Data Exchange (ETDEWEB)

    Gong, Changxiu [School of Environment, Tsinghua University, Beijing 100084 (China); Jiang, Jianguo, E-mail: jianguoj@mail.tsinghua.edu.cn [School of Environment, Tsinghua University, Beijing 100084 (China); Key Laboratory for Solid Waste Management and Environment Safety, Ministry of Education of China (China); Collaborative Innovation Center for Regional Environmental Quality, Tsinghua University, Beijing (China); Li, De' an [School of Environment, Tsinghua University, Beijing 100084 (China)

    2015-11-01

    We focused on the effects of ultrasound and Fenton reagent in ultrasonic coupling Fenton oxidation (U + F) pre-treatment processes on the disintegration of wastewater treatment plant sludge. The results demonstrated that U + F treatment could significantly increase soluble COD, TOC, total N, proteins, total P and PO{sub 4}{sup 3−} concentrations in sludge supernatant. This method was more effective than ultrasonic (U) or Fenton oxidation (F) treatment alone. U + F treatment increased the soluble COD by 2.1- and 1.4-fold compared with U and F alone, respectively. U + F treatment increased the total N and P by 1.7- and 2.2-fold, respectively, compared with F alone. After U + F treatment, sludge showed a considerably finer particle size and looser microstructure based on scanning electron microscopy, and the highest OH· signal intensity increased from 568.7 by F treatment to 1106.3 using electron spin resonance. This demonstrated that U + F treatment induces disintegration of sludge and release of organic carbon, nitrogen and phosphorus better. - Highlights: • Combined ultrasound–Fenton pre-treatment was proposed for sludge disintegration. • Ultrasound–Fenton significantly increased carbon, nitrogen and phosphorus release. • Higher level of OH· was detected after combined disintegration than Fenton.

  18. Ultrasound coupled with Fenton oxidation pre-treatment of sludge to release organic carbon, nitrogen and phosphorus

    International Nuclear Information System (INIS)

    Gong, Changxiu; Jiang, Jianguo; Li, De'an

    2015-01-01

    We focused on the effects of ultrasound and Fenton reagent in ultrasonic coupling Fenton oxidation (U + F) pre-treatment processes on the disintegration of wastewater treatment plant sludge. The results demonstrated that U + F treatment could significantly increase soluble COD, TOC, total N, proteins, total P and PO 4 3− concentrations in sludge supernatant. This method was more effective than ultrasonic (U) or Fenton oxidation (F) treatment alone. U + F treatment increased the soluble COD by 2.1- and 1.4-fold compared with U and F alone, respectively. U + F treatment increased the total N and P by 1.7- and 2.2-fold, respectively, compared with F alone. After U + F treatment, sludge showed a considerably finer particle size and looser microstructure based on scanning electron microscopy, and the highest OH· signal intensity increased from 568.7 by F treatment to 1106.3 using electron spin resonance. This demonstrated that U + F treatment induces disintegration of sludge and release of organic carbon, nitrogen and phosphorus better. - Highlights: • Combined ultrasound–Fenton pre-treatment was proposed for sludge disintegration. • Ultrasound–Fenton significantly increased carbon, nitrogen and phosphorus release. • Higher level of OH· was detected after combined disintegration than Fenton

  19. Fenton-like initiation of a toluene transformation mechanism

    Science.gov (United States)

    In Fenton-driven oxidation treatment systems, reaction intermediates derived from parent compounds can play a significant role in the overall treatment process. Fenton-like reactions in the presence of toluene or benzene, involved a transformation mechanism that was highly effici...

  20. IMPLEMENTASI SANDI HILL UNTUK PENYANDIAN CITRA

    Directory of Open Access Journals (Sweden)

    JJ Siang

    2002-01-01

    Full Text Available Hill's code is one of text encoding technique. In this research, Hill's code is extended to image encoding. The image used is BMP 24 bit format. 2x2 and 3x3 matrices is used as a key. The results show that Hill's code is suitable for image whose RGB values vary highly. On the contrary, it is not suitable for less varied RGB images since its original pattern is still persisted in encrypted image. Hill's code for image encoding has also disadvantage in the case that the key matrix is not unique. However, for daily application, with good key matrix, Hill's code can be applied to encode image since it's process only deals with simple matrix operation so it become fast. Abstract in Bahasa Indonesia : Sandi Hill merupakan salah satu teknik penyandian teks. Dalam penelitian ini, pemakaian sandi Hill diperluas dari teks ke citra bertipe BMP 24 bit. Matriks yang dipakai berordo 2x2 dan 3x3. Hasil percobaan menunjukkan bahwa sandi Hill cocok untuk enkripsi citra dengan variasi nilai RGB antar piksel berdekatan yang tinggi (seperti foto, tapi tidak cocok untuk citra dengan variasi nilai RGB yang rendah (seperti gambar kartun karena pola citra asli masih tampak dalam citra sandi. Sandi Hill juga memiliki kelemahan dalam hal tidak tunggalnya matriks kunci yang dapat dipakai. Akan tetapi untuk pemakaian biasa, dengan pemilihan matriks kunci yang baik, sandi Hill dapat dipakai untuk penyandian karena hanya melibatkan operasi matriks biasa sehingga prosesnya relatif cepat. Kata kunci: Sandi Hill, Citra, Relatif Prima.

  1. Application of the photo-fenton process to the mineralization of phthalic anhydride in aqueous medium

    International Nuclear Information System (INIS)

    Trabelsi Souissi, Souhaila; Oturan, N.; Oturan, M. A; Bellakhal, N.

    2009-01-01

    A photochemical method for the oxidation of persistent organic pollutants (POPs) present in liquid effluents of plastic industry is described. This method, called p hoto-Fenton , involves the generation of hydroxyl radicals by coupling the Fenton reaction and photochemistry, .OH radicals thus formed react rapidly with organic pollutants leading to their oxidation until their total mineralization. In this study, we applied the photo-Fenton process for the removal of phthalic anhydride (plasticizer). In this way, an optimization of experimental parameters (namely the ratio R = [H 2 O 2 ]/[Fe 3+ ] and Fe 3+ initial concentration) was performed. Under optimal conditions, the kinetic of mineralization of phthalic anhydride by .OH has been studied. All results confirm the efficiency of photo-Fenton process for the decontamination of liquid effluents loaded with plasticizers.

  2. Roles of iron species and pH optimization on sewage sludge conditioning with Fenton's reagent and lime.

    Science.gov (United States)

    Yu, Wenbo; Yang, Jiakuan; Shi, Yafei; Song, Jian; Shi, Yao; Xiao, Jun; Li, Chao; Xu, Xinyu; He, Shu; Liang, Sha; Wu, Xu; Hu, Jingping

    2016-05-15

    Conditioning sewage sludge with Fenton's reagent could effectively improve its dewaterability. However, drawbacks of conditioning with Fenton's reagent are requirement of acidic conditions to prevent iron precipitation and subsequent neutralization with alkaline additive to obtain the pH of the filtrate close to neutrality. In this study, roles of pH were thoroughly investigated in the acidification pretreatment, Fenton reaction, and the final filtrate after conditioning. Through the response surface methodology (RSM), the optimal dosages of H2SO4, Fe(2+), H2O2, and lime acted as a neutralizer were found to be 0 (no acidification), 47.9, 34.3 and 43.2 mg/g DS (dry solids). With those optimal doses, water content of the dewatered sludge cakes could be reduced to 55.8 ± 0.6 wt%, and pH of the final filtrate was 6.6 ± 0.2. Fenton conditioning without initial acidification can simplify the conditioning process and reduce the usage of lime. The Fe(3+) content in the sludge cakes showed a close correlation with the dewaterability of conditioned sludge, i.e., the water content of sludge cakes, SRF (specific resistance to filtration), CST (capillary suction time), bound water content, and specific surface area. It indicated that the coagulation by Fe(3+) species in Fenton reaction could play an important role, compared to traditional Fenton oxidation effect on sludge conditioning. Thus, a two-step mechanism of Fenton oxidation and Fe(III) coagulation was proposed in sewage sludge conditioning. The mechanisms include the following: (1) extracellular polymeric substances (EPS) were firstly degraded into dissolved organics by Fenton oxidation; (2) bound water was converted to free water due to degradation of EPS; (3) the sludge particles were disintegrated into small ones by oxidation; (4) Fe(3+) generated from Fenton reaction acted as a coagulant to agglomerate smaller sludge particles into larger dense particles with less bond water; (5) finally, the dewatered

  3. Fenton reagent and titanium dioxide nanoparticles as antifungal agents to control leaf spot of sugar beet under field conditions

    Directory of Open Access Journals (Sweden)

    Hamza Amany

    2016-07-01

    Full Text Available In this study, foliar sprays of Fenton solutions (Fenton reaction, Fenton-like reaction and Fenton complex, titanium dioxide (TiO2 and the recommended fungicide (chlorothalonil were estimated in the control of sugar beet leaf spot caused by Cercospora beticola under field conditions in two growing seasons. In addition, the impacts of these treatments on some crop characters (leaf dry weight, root fresh weight, soluble solid content, sucrose content and purity of sugar were examined. Biochemical and histological changes in the livers and kidneys of treated rats compared to an untreated control were utilized to assess the toxicity of the examined curative agents. Overall, chlorothalonil and Fenton complex were the most effective treatments for disease suppression in both tested seasons followed by Fenton-like reagent, Fenton’s reagent and TiO2, respectively. Growth and yield characters of treated sugar beet significantly increased in comparison to an untreated control. There were mild or no (biochemical and histological changes in the livers and kidneys of treated rats compared to the control. Fenton solutions and TiO2 may offer a new alternative for leaf spot control in sugar beet.

  4. Fenton detemplation of ordered (meso)porous materials

    NARCIS (Netherlands)

    Melian-Cabrera, I.; Osman, A. H.; van Eck, E. R. H.; Kentgens, Arno P.M.; Polushkin, E.; Kapteijn, F.; Moulijn, J. A.; Xu, R; Gao, Z; Chen, J; Yan, W

    2007-01-01

    This article describes a new methodology (Fenton detemplation), which consists of removing the template by chemical oxidation and develop the material's porosity. The oxidizing agents are OH radicals, which are generated from H(2)O(2) in the presence of catalytic amounts of Fe cations. This is known

  5. Effect of iron salt type and dosing mode on Fenton-based pretreatment of rice straw for enzymatic hydrolysis.

    Science.gov (United States)

    Gan, Yu-Yan; Zhou, Si-Li; Dai, Xiao; Wu, Han; Xiong, Zi-Yao; Qin, Yuan-Hang; Ma, Jiayu; Yang, Li; Wu, Zai-Kun; Wang, Tie-Lin; Wang, Wei-Guo; Wang, Cun-Wen

    2018-06-15

    Fenton-based processes with four different iron salts in two different dosing modes were used to pretreat rice straw (RS) samples to increase their enzymatic digestibility. The composition analysis shows that the RS sample pretreated by the dosing mode of iron salt adding into H 2 O 2 has a much lower hemicellulose content than that pretreated by the dosing mode of H 2 O 2 adding into iron salt, and the RS sample pretreated by the chloride salt-based Fenton process has a much lower lignin content and a slightly lower hemicellulose content than that pretreated by the sulphate salt-based Fenton process. The higher concentration of reducing sugar observed on the RS sample with lower lignin and hemicellulose contents justifies that the Fenton-based process could enhance the enzymic hydrolysis of RS by removing hemicellulose and lignin and increasing its accessibility to cellulase. FeCl 3 ·6H 2 O adding into H 2 O 2 is the most efficient Fenton-based process for RS pretreatment. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Simultaneous Removal of Thallium and EDTA by Fenton Process

    Science.gov (United States)

    Xu, Ruibing; Huang, Xuexia; Li, Huosheng; Su, Minhua; Chen, Diyun

    2018-01-01

    The wastewater containing heavy metals and organic pollutants is widely discharged from industries. Because of the coexistence of heavy metals and organic pollutants, the treatment of such wastewater is very difficult. Fenton process is considered to be one of the most effective approaches for the degradation of organic pollutants in aqueous solution due to the strong oxidative ability of hydroxyl radical which generated from the Fenton process. Apart from this, heavy metals are able to be removed during Fenton process owning to the synergic effect of coagulation and precipitation. In this work, pollutants of thallium and EDTA were successfully removed via the Fenton process. A series of single-factor experiments were designed and performed to achieve an optimal reaction conditions for the removal of both thallium and EDTA. Results showed that the removal efficiencies of thallium and TOC could be as high as 96.54% and 70.42%, respectively. The outcomes from our study demonstrate that Fenton process is a promising method for the purification of wastewater containing thallium and EDTA.

  7. Mechanism of red mud combined with Fenton's reagent in sewage sludge conditioning.

    Science.gov (United States)

    Zhang, Hao; Yang, Jiakuan; Yu, Wenbo; Luo, Sen; Peng, Li; Shen, Xingxing; Shi, Yafei; Zhang, Shinan; Song, Jian; Ye, Nan; Li, Ye; Yang, Changzhu; Liang, Sha

    2014-08-01

    Red mud was evaluated as an alternative skeleton builder combined with Fenton's reagent in sewage sludge conditioning. The results show that red mud combined with Fenton's reagent showed good conditioning capability with the pH of the filtrate close to neutrality, indicating that red mud acted as a neutralizer as well as a skeleton builder when jointly used with Fenton's reagent. Through response surface methodology (RSM), the optimal dosages of Fe(2+), H2O2 and red mud were proposed as 31.9, 33.7 and 275.1 mg/g DS (dry solids), respectively. The mechanism of the composite conditioner could be illuminated as follows: (1) extracellular polymeric substances (EPS), including loosely bound EPS and tightly bound EPS, were degraded into dissolved organics, e.g., proteins and polysaccharides; (2) bound water was released and converted into free water due to the degradation of EPS; and (3) morphology of the conditioned sludge exhibited a porous structure in contrast with the compact structure of raw sludge, and the addition of red mud formed new mineral phases and a rigid lattice structure in sludge, allowing the outflow of free water. Thus, sludge dewatering performance was effectively improved. The economic assessment for a wastewater treatment plant of 370,000 equivalent inhabitants confirms that using red mud conditioning, combined with Fenton's reagent, leads to a saving of approximately 411,000 USD/y or 50.8 USD/t DS comparing with using lime and ordinary Portland cement combined with Fenton's reagent, and approximately 612,000 USD/y or 75.5 USD/t DS comparing with the traditional treatment. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Effect of the ultrasound-Fenton oxidation process with the addition of a chelating agent on the removal of petroleum-based contaminants from soil.

    Science.gov (United States)

    Li, Ying; Li, Fangmin; Li, Fanxiu; Yuan, Fuqian; Wei, Pingfang

    2015-12-01

    The effects of ultrasonic irradiation, the chelating agent modified Fenton reaction, and a combination of ultrasound and the Fenton method in removing petroleum contaminants from a soil were studied. The results showed that the contaminant removal rate of the Fenton treatment combined with an oxalic acid chelating agent was 55.6% higher than that without a chelating agent. The average removal rate of the contaminants using the ultrasound-Fenton treatment was 59.0% higher than that without ultrasonic treatment. A combination of ultrasound and an Fe(2+)/Fe(3+)-oxalate complex-modified Fenton reagent resulted in significantly higher removal rates of n-alkanes (C(n)H(2n+2), n Fenton method. The Fenton reaction and the ultrasound-Fenton treatment can unselectively remove multiple components of residual hydrocarbons and a number of benzene rings in polycyclic aromatic hydrocarbons. The chemistry of the heterocyclic compounds and the position and number of substituents can affect the degradation process.

  9. Sodium hypochlorite as an alternative to hydrogen peroxide in Fenton process for industrial scale.

    Science.gov (United States)

    Behin, Jamshid; Akbari, Abbas; Mahmoudi, Mohsen; Khajeh, Mehdi

    2017-09-15

    In present work, the treatment of aromatic compounds of simulated wastewater was performed by Fenton and NaOCl/Fe 2+ processes. The model solution was prepared based on the wastewater composition of Diisocyanate unit of Karoon Petrochemical Company/Iran containing Diamino-toluenes, Nitro-phenol, Mononitro-toluene, Nitro-cresol, and Dinitro-toluene. Experiments were conducted in a batch mode to examine the effects of operating variables such as pH, oxidant dosages, ferrous ion concentration and numbers of feeding on COD removal. Taguchi experimental design was used to determine the optimum conditions. The COD removal efficiency under optimum conditions (suggested by Taguchi design) in Fenton and NaOCl/Fe 2+ processes was 88.7% and 83.4%, respectively. The highest contribution factor in Fenton process belongs to pH (47.47%) and in NaOCl/Fe 2+ process belongs to NaOCl/pollutants (50.26%). High regression coefficient (R 2 : 0.98) obtained for Taguchi method, indicates that models are statistically significant and are in well agreement with each other. The NaOCl/Fe 2+ process utilizing a conventional oxidant, in comparison to hydrogen peroxide, is an efficient cost effective process for COD removal from real wastewater, although the removal efficiency is not as high as in Fenton process; however it is a suitable process to replace Fenton process in industrial scale for wastewater involved aromatic compounds with high COD. This process was successfully applied in Karoon Petrochemical Company/Iran. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Research on the Treatment of Aluminum Alloy Chemical Milling Wastewater with Fenton Process

    Science.gov (United States)

    Zong-liang, Huang; Ru, Li; Peng, Luo; Jun-li, Gu

    2018-03-01

    The aluminum alloy chemical milling wastewater was treated by Fenton method. The effect of pH value, reaction time, rotational speed, H2O2 dosage, Fe2+ dosage and the molar ratio between H2O2 and Fe2+ on the COD removal rate of aluminum alloy chemical milling wastewater were investigated by single factor experiment and orthogonal experiment. The results showed that the optimum operating conditions for Fenton oxidation were as follows: the initial pH value was 3, the rotational speed was 250r/min, the molar ratio of H2O2 and Fe2+ was 8, the reaction time was 90 min. Under the optimum conditions, the removal rate of the wastewater’s COD is about 72.36%. In the reaction kinetics that aluminum alloy chemical milling wastewater was oxidized and degraded by Fenton method under the optimum conditions, the reaction sequence of the initial COD was 0.8204.

  11. TPH2 -703G/T SNP may have important effect on susceptibility to suicidal behavior in major depression.

    Science.gov (United States)

    Yoon, Ho-Kyoung; Kim, Yong-Ku

    2009-04-30

    Serotonergic system-related genes can be good candidate genes for both major depressive disorder (MDD) and suicidal behavior. In this study, we aimed to investigate the association of serotonin 2A receptor gene -1438A/G SNP (HTR2A -1438A/G), tryptophan hydroxylase 2 gene -703G/T SNP (TPH2 -703G/T) and serotonin 1A receptor C-1019G (HTR1A C-1019G) with suicidal behavior. One hundred and eighty one suicidal depressed patients and 143 non-suicidal depressed patients who met DSM-IV criteria for major depressive disorder were recruited from patients who were admitted to Korea University Ansan Hospital. One hundred seventy six normal controls were healthy volunteers who were recruited by local advertisement. Patients and normal controls were genotyped for HTR2A -1438A/G, TPH2 -703G/T and 5-HT1A C-1019G. The suicidal depressed patients were evaluated by the lethality of individual suicide attempts using Weisman and Worden's risk-rescue rating (RRR) and the Lethality Suicide Attempt Rating Scale-updated (LSARS-II). In order to assess the severity of depressive symptoms of patients, Hamilton's Depression Rating Scale (HDRS) was administered. Genotype and allele frequencies were compared between groups by chi(2) statistics. Association of genotype of the candidate genes with the lethality of suicidal behavior was examined with ANOVA by comparing the mean scores of LSARS and RRR according to the genotype. There were statistically significant differences in the genotype distributions and allele frequencies of TPH2 -703G/T between the suicidal depressive group and the normal control group. The homozygous allele G (G/G genotype) frequency was significantly higher in suicidal depressed patients than in controls. However, no differences in either genotype distribution or in allele frequencies of HTR2A -1438A/G and HTR1A C-1019G were observed between the suicidal depressed patients, the non-suicidal depressed patients, and the normal controls. There were no differences in the

  12. Electro-Fenton and photoelectro-Fenton degradations of the drug beta-blocker propranolol using a Pt anode: Identification and evolution of oxidation products

    Energy Technology Data Exchange (ETDEWEB)

    Isarain-Chavez, Eloy; Cabot, Pere Lluis; Centellas, Francesc; Rodriguez, Rosa Maria; Arias, Conchita; Garrido, Jose Antonio [Laboratori d' Electroquimica dels Materials i del Medi Ambient, Departament de Quimica Fisica, Facultat de Quimica, Universitat de Barcelona, Marti i Franques 1-11, 08028 Barcelona (Spain); Brillas, Enric, E-mail: brillas@ub.edu [Laboratori d' Electroquimica dels Materials i del Medi Ambient, Departament de Quimica Fisica, Facultat de Quimica, Universitat de Barcelona, Marti i Franques 1-11, 08028 Barcelona (Spain)

    2011-01-30

    The beta-blocker propranolol hydrochloride has been degraded by electrochemical advanced oxidation processes like electro-Fenton (EF) and photoelectro-Fenton (PEF) using a single cell with a Pt anode and an air diffusion cathode (ADE) for H{sub 2}O{sub 2} electrogeneration and a combined system containing the above Pt/ADE pair coupled in parallel to a Pt/carbon-felt (CF) cell. Organics are mainly oxidized with hydroxyl radical ({center_dot}OH) formed from Fenton's reaction between added Fe{sup 2+} and electrogenerated H{sub 2}O{sub 2}. The PEF treatment in Pt/ADE-Pt/CF system yields almost total mineralization because {center_dot}OH production is enhanced by Fe{sup 2+} regeneration from Fe{sup 3+} reduction at the CF cathode and Fe(III) complexes with generated carboxylic acids are rapidly photodecarboxylated under UVA irradiation. Lower mineralization degree is found for PEF in Pt/ADE cell due to the little influence of UVA light on Fe{sup 2+} regeneration. The homologous EF processes are much less potent as a result of the persistence of Fe(III)-carboxylate complexes. Aromatic intermediates such as 1-naphthol, 1,4-naphthoquinone and phthalic acid and generated carboxylic acids such as pyruvic, glycolic, malonic, maleic, oxamic, oxalic and formic are identified. While chloride ion remains stable, NH{sub 4}{sup +} and NO{sub 3}{sup -} ions are released to the medium. A reaction sequence for propranolol hydrochloride mineralization is proposed.

  13. Efficient and Stable Carbon-coated Nickel Foam Cathodes for the Electro-Fenton Process

    International Nuclear Information System (INIS)

    Song, Shuqin; Wu, Mingmei; Liu, Yuhui; Zhu, Qiping; Tsiakaras, Panagiotis; Wang, Yi

    2015-01-01

    Highlights: • Carbon-coated nickel foam (C@NF) was prepared by cycle coating carbon process. • Ni leaching can be effectively controlled at C@NF4 (4 cycle coating times) cathode. • C@NF4 exhibits excellent electro-Fenton performance with desirable stability. • C@NF4 exhibits low energy consumption for DMP degradation. - Abstract: Carbon-coated nickel foam (C@NF) electrodes are prepared via a simple and effective method, hydrothermal-carbonization cycle coating process, characterized by scanning electron microscopy (SEM) with energy dispersive spectrometer (EDS) and employed as the electro-Fenton (E-Fenton) cathode for degrading dimethyl phthalate (DMP) in aqueous solution. For the sake of comparison, nickel foam (NF) electrode and the conventional E-Fenton cathode (graphite gas diffusion electrode (GDE)) are also tested and compared. Experimental results indicate that nickel leaching can be effectively controlled at C@NF4 cathode (4 times cycle coating process), having great significance for promoting the application of NF in E-Fenton system. Moreover, C@NF4 cathode still presents excellent and effective performance on DMP degradation. DMP can be completely degraded within 2 h at −0.5 V and the total organic carbon (TOC) removal reaches as high as 82.1 %, which is almost 3 times as high as that at graphite GDE. Futhermore, the current efficiency for H 2 O 2 generation at C@NF4 is enhanced by 12 times compared to that at NF, and consequently the energy consumption during DMP degradation at C@NF4 is obvious lower than that at both NF cathode and graphite GDE. From the obtained results it can be deduced that C@NF4 is promising to be an attractive alternative E-Fenton cathode for removing organic pollutants in wastewater

  14. Development of a trickle bed reactor of electro-Fenton process for wastewater treatment

    Energy Technology Data Exchange (ETDEWEB)

    Lei, Yangming [Key Laboratory of Reservoir Aquatic Environment, Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 401122 (China); School of Environmental Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240 (China); Liu, Hong, E-mail: liuhong@cigit.ac.cn [Key Laboratory of Reservoir Aquatic Environment, Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 401122 (China); Shen, Zhemin, E-mail: zmshen@sjtu.edu.cn [School of Environmental Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240 (China); Wang, Wenhua [School of Environmental Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240 (China)

    2013-10-15

    Highlights: • An electrochemical trickle bed reactor was composed of C-PTFE-coated graphite chips. • The trickle bed reactor had a high H{sub 2}O{sub 2} production rate in a dilute electrolyte. • An azo dye was effectively decomposed by the electro-Fenton process in the reactor. -- Abstract: To avoid electrolyte leakage and gas bubbles in the electro-Fenton (E-Fenton) reactors using a gas diffusion cathode, we developed a trickle bed cathode by coating a layer composed of carbon black and polytetrafluoroethylene (C-PTFE) onto graphite chips instead of carbon cloth. The trickle bed cathode was optimized by single-factor and orthogonal experiments, in which carbon black, PTFE, and a surfactant were considered as the determinant of the performance of graphite chips. In the reactor assembled by the trickle bed cathode, H{sub 2}O{sub 2} was generated with a current of 0.3 A and a current efficiency of 60%. This performance was attributed to the fine distribution of electrolyte and air, as well as the effective oxygen transfer from the gas phase to the electrolyte–cathode interface. In terms of H{sub 2}O{sub 2} generation and current efficiency, the developed trickle bed reactor had a performance comparable to that of the conventional E-Fenton reactor using a gas diffusion cathode. Further, 123 mg L{sup −1} of reactive brilliant red X-3B in aqueous solution was decomposed in the optimized trickle bed reactor as E-Fenton reactor. The decolorization ratio reached 97% within 20 min, and the mineralization reached 87% within 3 h.

  15. Fenton-like chemistry in water: Oxidation catalysis by Fe(III) and H2O2

    NARCIS (Netherlands)

    Ensing, B.; Buda, F.; Baerends, E.J.

    2003-01-01

    The formation of active intermediates from the Fenton-like reagent (a mixture of iron(III) ions and hydrogen peroxide) in aqueous solution has been investigated using static DFT calculations and Car-Parrinello molecular dynamics simulations. We show the spontaneous formation of the iron(III)

  16. Fenton oxidative decolorization of the azo dye Direct Blue 15 in aqueous solution

    DEFF Research Database (Denmark)

    Sun, Jian-Hui; Shi, Shao-Hui; Lee, Yi-Fan

    2009-01-01

    In this paper, the application of Fenton oxidation process for the decolorization of an azo dye Direct Blue 15 (DB15) in aqueous solution was investigated. The effect of initial pH, dosage of H2O2, H2O2/Fe2+ and H2O2/dye ratios and the reaction temperature on the decolorization efficiency...... = 60: 1 and temperature = 30 degrees C. Under the optimal conditions, 4.7 x 10(-5) mol/L of the DB15 aqueous solution can be completely decolorized by Fenton oxidation within 50-min reaction time and the decolorization kinetic rate constant k was determined as 0.1694 min(-1). Additionally increasing...... the reaction temperature from 20 to 40 degrees C showed a positive effect on the decolorization efficiency of DB15. The present study can provide guidance to relational industry operators and planners to effectively treat the DB15 contaminated wastewater by Fenton oxidation process. (C) 2009 Elsevier B. V. All...

  17. Improving degradation of paracetamol by integrating gamma radiation and Fenton processes.

    Science.gov (United States)

    Cruz-González, Germán; Rivas-Ortiz, Iram B; González-Labrada, Katia; Rapado-Paneque, Manuel; Chávez-Ardanza, Armando; Nuevas-Paz, Lauro; Jáuregui-Haza, Ulises J

    2016-10-14

    Degradation of paracetamol (N-(4-hydroxiphenyl)acetamide) in aqueous solution by gamma radiation, gamma radiation/H2O2 and gamma radiation/Fenton processes was studied. Parameters affecting the radiolysis of paracetamol such as radiation dose, initial concentration of pollutant, pH and initial oxidant concentration were investigated. Gamma radiation was performed using a (60)Co source irradiator. Paracetamol degradation and mineralization increased with increasing absorbed radiation dose, but decreased with increasing initial concentration of the drug in aqueous solution. The addition of H2O2 resulted in an increased effect on irradiation-driven paracetamol degradation in comparison with the performance of the irradiation-driven process alone: paracetamol removal increased from 48.9% in the absence of H2O2 to 95.2% for H2O2 concentration of 41.7 mmol/L. However, the best results were obtained with gamma radiation/Fenton process with 100% of the drug removal at 5 kGy, for optimal H2O2 and Fe(2+) concentrations at 13.9 and 2.3 mmol/L, respectively, with a high mineralization of 63.7%. These results suggest gamma radiation/H2O2 and gamma radiation/Fenton processes as promising methods for paracetamol degradation in polluted wastewaters.

  18. Effects of iron type in Fenton reaction on mineralization and biodegradability enhancement of hazardous organic compounds.

    Science.gov (United States)

    Khan, Eakalak; Wirojanagud, Wanpen; Sermsai, Nawarat

    2009-01-30

    The mineralization and biodegradability increase and their combination of two traditional and two relatively new organic contaminants by Fenton reagents with three different types of iron, Fe(2+), Fe(3+), and Fe(0) were investigated. The traditional contaminants examined were trichloroethene (TCE) and 2,4-dichlorophenol (2,4-DCP) while 1,4-dioxane (1,4-D) and 1,2,3-trichloropropane (TCP) were studied for the relatively new contaminants. The mineralization and biodegradability were represented by dissolved organic carbon (DOC) reduction and the ratio of biodegradable dissolved organic carbon and DOC, respectively. For all four contaminants, Fenton reagent using Fe(2+) was more effective in the DOC reduction than Fenton reagents using Fe(3+) and Fe(0) in most cases. The types of Fe that provided maximum biodegradability increase were not the same for all four compounds, Fe(3+) for TCE, Fe(0) for 2,4-DCP, Fe(2+) for 1,4-D, and Fe(3+) for TCP. When the combination of DOC elimination and biodegradability increase (least refractory fraction) was considered, Fe(2+) was the best choice except for 2,4-DCP which was susceptible to Fe(0) catalyzed Fenton reagent the most. The least refractory fractions remaining after 120 min of reaction were 20-25% for TCE, 2,4-DCP, and TCP and 30-40% for 1,4-D. The iron type in Fenton reaction also affected the type of mineralization kinetics of TCE, 2,4-DCP, and TCP as well as the types of degradation by-products of these contaminants. Some of the by-products found, such as isopropanol and propionic aldehyde, which were produced from Fe(0) catalyzed Fenton degradation of TCP, have not been previously reported.

  19. Sequential Combination of Electro-Fenton and Electrochemical Chlorination Processes for the Treatment of Anaerobically-Digested Food Wastewater.

    Science.gov (United States)

    Shin, Yong-Uk; Yoo, Ha-Young; Kim, Seonghun; Chung, Kyung-Mi; Park, Yong-Gyun; Hwang, Kwang-Hyun; Hong, Seok Won; Park, Hyunwoong; Cho, Kangwoo; Lee, Jaesang

    2017-09-19

    A two-stage sequential electro-Fenton (E-Fenton) oxidation followed by electrochemical chlorination (EC) was demonstrated to concomitantly treat high concentrations of organic carbon and ammonium nitrogen (NH 4 + -N) in real anaerobically digested food wastewater (ADFW). The anodic Fenton process caused the rapid mineralization of phenol as a model substrate through the production of hydroxyl radical as the main oxidant. The electrochemical oxidation of NH 4 + by a dimensionally stable anode (DSA) resulted in temporal concentration profiles of combined and free chlorine species that were analogous to those during the conventional breakpoint chlorination of NH 4 + . Together with the minimal production of nitrate, this confirmed that the conversion of NH 4 + to nitrogen gas was electrochemically achievable. The monitoring of treatment performance with varying key parameters (e.g., current density, H 2 O 2 feeding rate, pH, NaCl loading, and DSA type) led to the optimization of two component systems. The comparative evaluation of two sequentially combined systems (i.e., the E-Fenton-EC system versus the EC-E-Fenton system) using the mixture of phenol and NH 4 + under the predetermined optimal conditions suggested the superiority of the E-Fenton-EC system in terms of treatment efficiency and energy consumption. Finally, the sequential E-Fenton-EC process effectively mineralized organic carbon and decomposed NH 4 + -N in the real ADFW without external supply of NaCl.

  20. Treatment of amoxicillin by O3/Fenton process in a rotating packed bed.

    Science.gov (United States)

    Li, Mo; Zeng, Zequan; Li, Yingwen; Arowo, Moses; Chen, Jianfeng; Meng, Hong; Shao, Lei

    2015-03-01

    In this study, simulated amoxicillin wastewater was treated by the O3/Fenton process in a rotating packed bed (RPB) and the results were compared with the Fenton process and the O3 followed by Fenton (O3 + Fenton) process. The chemical oxygen demand (COD) removal rate and the ratio of 5-day biological oxygen demand to chemical oxygen demand (BOD5/COD) in the O3/Fenton process were approximately 17% and 26%, respectively, higher than those in the O3 + Fenton process with an initial pH of 3. The COD removal rate of the amoxicillin solution reached maximum at the Fe(II) concentration of 0.6 mM, temperature of 25 °C, rotation speed of 800 rpm and initial pH of 3. The BOD5/COD of the amoxicillin solution increased from 0 to 0.38 after the solution was treated by the O3/Fenton process. Analysis of the intermediates indicated that the pathway of amoxicillin degradation in the O3/Fenton process was similar to that in the O3 + Fenton process. Contrast experiment results showed that amoxicillin degradation was significantly intensified in the RPB. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Treatment of oilfield wastewater by combined process of micro-electrolysis, Fenton oxidation and coagulation.

    Science.gov (United States)

    Zhang, Zhenchao

    2017-12-01

    In this study, a combined process was developed that included micro-electrolysis, Fenton oxidation and coagulation to treat oilfield fracturing wastewater. Micro-electrolysis and Fenton oxidation were applied to reduce chemical oxygen demand (COD) organic load and to enhance organic components gradability, respectively. Orthogonal experiment were employed to investigate the influence factors of micro-electrolysis and Fenton oxidation on COD removal efficiency. For micro-electrolysis, the optimum conditions were: pH, 3; iron-carbon dosage, 50 mg/L; mass ratio of iron-carbon, 2:3; reaction time, 60 min. For Fenton oxidation, a total reaction time of 90 min, a H 2 O 2 dosage of 12 mg/L, with a H 2 O 2 /Fe 2+ mole ratio of 30, pH of 3 were selected to achieve optimum oxidation. The optimum conditions in coagulation process: pH, cationic polyacrylamide dosage, mixing speed and time is 4.3, 2 mg/L, 150 rpm and 30 s, respectively. In the continuous treatment process under optimized conditions, the COD of oily wastewater fell 56.95%, 46.23%, 30.67%, respectively, from last stage and the total COD removal efficiency reached 83.94% (from 4,314 to 693 mg/L). In the overall treatment process under optimized conditions, the COD of oily wastewater was reduced from 4,314 to 637 mg/L, and the COD removal efficiency reached 85.23%. The contribution of each stage is 68.45% (micro-electrolysis), 24.07% (Fenton oxidation), 7.48% (coagulation), respectively. Micro-electrolysis is the uppermost influencing process on COD removal. Compared with the COD removal efficiency of three processes on raw wastewater under optimized conditions: the COD removal efficiency of single micro-electrolysis, single Fenton oxidation, single coagulation is 58.34%, 44.88% and 39.72%, respectively. Experiments proved the effect of combined process is marvelous and the overall water quality of the final effluent could meet the class III national wastewater discharge standard of petrochemical industry of China

  2. Photo-Fenton degradation of the insecticide esfenvalerate in aqueous medium using a recirculation flow-through UV photoreactor

    International Nuclear Information System (INIS)

    Colombo, Renata; Ferreira, Tanare C.R.; Alves, Suellen A.; Lanza, Marcos R.V.

    2011-01-01

    Highlights: ► The photo-Fenton reaction provides an efficient process by which to degrade esfenvalerate in aqueous suspensions. ► Photo-Fenton oxidation with Fe 3+ is more efficient in degrading esfenvalerate than the Fe 2+ -based reaction. ► Esfenvalerate was degraded most efficiently by photo-Fenton reaction in the presence of 5 mM Fe 3+ complex and 25 mM hydrogen peroxide at pH 2.5. ► The degradation of esfenvalerate by photo-Fenton (Fe 3+ ) generates organic by-products. ► Organic compounds present in commercial esfenvalerate-based insecticides affect the degradation process. - Abstract: The aim of the study was to evaluate the efficiencies of photo-Fenton (Fe 2+ ) and (Fe 3+ ) processes in the degradation of high-concentrations of esfenvalerate (in the form of aqueous emulsion of a commercial formulation) using a recirculation flow-through photoreactor irradiated with UV light from a 15 W lamp (254 nm emission peak). The results obtained using a basic photo-Fenton (Fe 2+ ) reaction (esfenvalerate 17 mg L −1 ; ferrous sulphate 1 mM; hydrogen peroxide 25 mM; pH 2.5) were compared with those acquired when ferrioxalate (1, 3 or 5 mM) served as the iron source. Degradation of the active component of the commercial formulation was significantly greater, and the rate of oxidation more rapid, using a photo-Fenton (Fe 3+ ) process compared with its Fe 2+ counterpart. The most efficient degradation of the insecticide (75% in 180 min) was achieved with a reaction mixture containing 5 mM ferrioxalate. However, under the same experimental conditions, degradation of pure esfenvalerate preceded much faster (99% in 60 min) and was 100% complete within 180 min reaction time.

  3. Feasibility of bioleaching combined with Fenton-like reaction to remove heavy metals from sewage sludge.

    Science.gov (United States)

    Zhu, Yi; Zeng, Guangming; Zhang, Panyue; Zhang, Chang; Ren, Miaomiao; Zhang, Jiachao; Chen, Ming

    2013-08-01

    Feasibility of bioleaching combining with Fenton-like reaction to remove heavy metals from sewage sludge was investigated. After 5-day bioleaching, the sludge pH decreased from 6.95 to 2.50, which satisfied the acidic conditions for Fenton-like reaction. Meanwhile, more than 50% of sludge-borne heavy metals were dissolved except for Pb. The bioleached sludge was further oxidized with Fenton-like reaction, with an optimal H2O2 dosage of 5 g/L, the Cu, Zn, Pb and Cd removal reached up to 75.3%, 72.6%, 34.5% and 65.4%, respectively, and the residual content of heavy metals in treated sludge meets the requirement of Disposal of Sludge from Municipal Wastewater Treatment Plant - Control Standards for Agricultural Use (CJ/T 309-2009) of China for A grade sludge. Bioleaching combined with Fenton-like reaction was the most effective method for heavy metal removal, compared with 15-day bioleaching and inorganic acid leaching with 10% H2SO4, 10% HCl and 10% HNO3. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Fenton-Driven Regeneration of MTBE-spent Granular Activated Carbon

    Science.gov (United States)

    Fenton-driven regeneration of Methyl tert-butyl ether (MTBE)-spent granular activated carbon (GAC) involves the combined, synergistic use of two treatment technologies: adsorption of organic chemicals onto activated carbon and Fenton-driven oxidation regeneration of the spent-GAC...

  5. Fenton Redox Chemistry : Arsenite Oxidation by Metallic Surfaces

    NARCIS (Netherlands)

    Borges Freitas, S.C.; Van Halem, D.; Badruzzaman, A.B.M.; Van der Meer, W.G.J.

    2014-01-01

    Pre-oxidation of As(III) is necessary in arsenic removal processes in order to increase its efficiency. Therefore, the Fenton Redox Chemistry is defined by catalytic activation of H2O2 and currently common used for its redox oxidative properties. In this study the effect of H2O2 production catalysed

  6. A combined process of adsorption and Fenton-like oxidation for furfural removal using zero-valent iron residue.

    Science.gov (United States)

    Li, Furong; Bao, Jianguo; Zhang, Tian C; Lei, Yutian

    2015-01-01

    In this study, the feasibility of using a combined adsorption and Fenton-like oxidation process (with zero-valent iron (ZVI) residue from heat wraps as an absorbent and catalyst) to remove furfural in the solution was evaluated. The influencing parameters (e.g. pH, H2O2 concentration, initial furfural concentration) and the reusability of ZVI residue (to replace the iron powder) were estimated. The ZVI residue was found to have much better adsorption effect on furfural at pH 2.0 compared with pH 6.7. For Fenton-like reaction alone with ZVI residue, the highest furfural removal of 97.5% was observed at the concentration of 0.176 mol/L H2O2, and all of the samples had >80% removal efficiency at different initial furfural concentrations of 2, 10, 20, 30 and 40 mmol/L. However, with a combined adsorption and Fenton-like oxidation, the removal efficiency of furfural was nearly 100% for all treatments. The ZVI residue used for furfural removal was much better than that of iron powder in the Fenton-like reaction at a seven-cycle experiment. This study suggests the combined process of adsorption and Fenton-like oxidation using ZVI residue is effective for the treatment of furfural in the liquid.

  7. Microwave enhanced Fenton-like process for the treatment of high concentration pharmaceutical wastewater

    International Nuclear Information System (INIS)

    Yang Yu; Wang Peng; Shi Shujie; Liu Yuan

    2009-01-01

    This paper explored a novel process for wastewater treatment, i.e. microwave enhanced Fenton-like process. This novel process was introduced to treat high concentration pharmaceutical wastewater with initial COD loading of 49,912.5 mg L -1 . Operating parameters were investigated and the optimal condition included as follows: microwave power was 300 W, radiation time was 6 min, initial pH was 4.42, H 2 O 2 dosage was 1300 mg L -1 and Fe 2 (SO 4 ) 3 dosage was 4900 mg L -1 , respectively. Within the present experimental condition used, the COD removal and UV 254 removal reached to 57.53% and 55.06%, respectively, and BOD 5 /COD was enhanced from 0.165 to 0.470. The variation of molecular weight distribution indicated that both macromolecular substances and micromolecular substances were eliminated quite well. The structure of flocs revealed that one ferric hydrated ion seemed to connect with another ferric hydrated ion and/or organic compound molecule to form large-scale particles by means of van der waals force and/or hydrogen bond. Subsequently, these particles aggregated to form flocs and settled down. Comparing with traditional Fenton-like reaction and conventional heating assisted Fenton-like reaction, microwave enhanced Fenton-like process displayed superior treatment efficiency. Microwave was in favor of improving the degradation efficiency, the settling quality of sludge, as well as reducing the yield of sludge and enhancing the biodegradability of effluent. Microwave enhanced Fenton-like process is believed to be a promising treatment technology for high concentration and biorefractory wastewater.

  8. Application of Fenton oxidation to cosmetic wastewaters treatment.

    Science.gov (United States)

    Bautista, P; Mohedano, A F; Gilarranz, M A; Casas, J A; Rodriguez, J J

    2007-05-08

    The removal of organic matter (TOC and COD) from a cosmetic wastewater by Fenton oxidation treatment has been evaluated. The operating conditions (temperature as well as ferrous ion and hydrogen peroxide dosage) have been optimized. Working at an initial pH equal to 3.0, a Fe(2+) concentration of 200 mg/L and a H(2)O(2) concentration to COD initial weight ratio corresponding to the theoretical stoichiometric value (2.12), a TOC conversion higher than 45% at 25 degrees C and 60% at 50 degrees C was achieved. Application of the Fenton oxidation process allows to reach the COD regional limit for industrial wastewaters discharges to the municipal sewer system. A simple kinetic analysis based on TOC was carried out. A second-order equation describes well the overall kinetics of the process within a wide TOC conversion range covering up to the 80-90% of the maximum achievable conversion.

  9. Efficient degradation of sulfamethazine in simulated and real wastewater at slightly basic pH values using Co-SAM-SCS /H2O2 Fenton-like system.

    Science.gov (United States)

    Cheng, Min; Zeng, Guangming; Huang, Danlian; Lai, Cui; Liu, Yang; Zhang, Chen; Wan, Jia; Hu, Liang; Zhou, Chengyun; Xiong, Weiping

    2018-07-01

    The presence of antibiotics in aquatic environments has attracted global concern. Fenton process is an attractive yet challenging method for antibiotics degradation, especially when such a reaction can be conducted at neutral pH values. In this study, a novel composite Fe/Co catalyst was synthesized via the modification of steel converter slag (SCS) by salicylic acid-methanol (SAM) and cobalt nitrate (Co(NO 3 ) 2 ). The catalysts were characterized by N 2 -Brunauer-Emmett-Teller (BET), X-ray diffraction (XRD), Fourier transform infrared (FT-IR), X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS). The results indicated that the Co-SAM-SCS/H 2 O 2 Fenton-like system was very effective for sulfamethazine (SMZ) degradation at a wide pH range. At initial pH of 7.0, the degradation rate of SMZ in Co-SAM-SCS/H 2 O 2 system was 2.48, 3.20, 6.18, and 16.21 times of that in Fe-SAM-SCS/H 2 O 2 , SAM-SCS/H 2 O 2 , Co(NO 3 ) 2 /H 2 O 2 and SCS/H 2 O 2 system, respectively. The preliminary analysis suggested that high surface area of Co-SAM-SCS sample and synergistic effect between introduced Co and SAM-SCS are responsible for the efficient catalytic activity. During the degradation, three main intermediates were identified by high performance liquid chromatography-mass spectrometry (HPLC-MS) analysis. Based on this, a possible degradation pathway was proposed. The SEM images, XRD patterns and XPS spectra before and after the reactions demonstrate that the crystal and chemical structure of Co-SAM-SCS after five cycles are almost unchanged. Besides, the Co-SAM-SCS presented low iron and cobalt leaching (0.17 mg/L and 2.36 mg/L, respectively). The studied Fenton-like process also showed high degradation of SMZ in river water and municipal wastewater. The progress will bring valuable insights to develop high-performance heterogeneous Fenton-like catalysts for environmental remediation. Copyright © 2018

  10. Removal of organic pollutants from produced water using Fenton oxidation

    Directory of Open Access Journals (Sweden)

    Afzal Talia

    2018-01-01

    Full Text Available Produced water (PW is the largest stream of wastewater from oil and gas exploration. It is highly polluted and requires proper treatment before disposal. The main objective of this study was to investigate the effectiveness of Fenton oxidation in degradation of organic matter in PW. The role of operating factors viz., H2O2 concentration (0.12 × 10-3 moles/L to 3 moles/L, [H2O2]/[Fe2+] molar ratio (2 to 75, and reaction time (30 to 200 minutes, on COD removal was determined through a series of batch experiments conducted in acidic environment at room temperature. The experiments were conducted with 500 mL PW samples in 1L glass beakers covered on the outside with aluminum foil to protect them from sunlight. Pre-decided amounts of ferrous sulfate heptahydrate (FeSO4.7H2O and hydrogen peroxide (H2O2 were added to initiate the Fenton reaction. An increase in COD removal was observed with increase in reaction time and [H2O2]/[Fe2+] molar ratio. COD removal also increased with H2O2 concentration up to 0.01 moles/L; further increase in H2O2 concentration decreased the COD removal efficiency. Over 90% COD removal was achieved under optimum reaction conditions. The study indicates that Fenton oxidation is effective for remediation of PW in terms of organic matter removal.

  11. Removal of organic pollutants from produced water using Fenton oxidation

    Science.gov (United States)

    Afzal, Talia; Hasnain Isa, Mohamed; Mustafa, Muhammad Raza ul

    2018-03-01

    Produced water (PW) is the largest stream of wastewater from oil and gas exploration. It is highly polluted and requires proper treatment before disposal. The main objective of this study was to investigate the effectiveness of Fenton oxidation in degradation of organic matter in PW. The role of operating factors viz., H2O2 concentration (0.12 × 10-3 moles/L to 3 moles/L), [H2O2]/[Fe2+] molar ratio (2 to 75), and reaction time (30 to 200 minutes), on COD removal was determined through a series of batch experiments conducted in acidic environment at room temperature. The experiments were conducted with 500 mL PW samples in 1L glass beakers covered on the outside with aluminum foil to protect them from sunlight. Pre-decided amounts of ferrous sulfate heptahydrate (FeSO4.7H2O) and hydrogen peroxide (H2O2) were added to initiate the Fenton reaction. An increase in COD removal was observed with increase in reaction time and [H2O2]/[Fe2+] molar ratio. COD removal also increased with H2O2 concentration up to 0.01 moles/L; further increase in H2O2 concentration decreased the COD removal efficiency. Over 90% COD removal was achieved under optimum reaction conditions. The study indicates that Fenton oxidation is effective for remediation of PW in terms of organic matter removal.

  12. Heterogeneous electro-Fenton catalyst for 1-butylpyridinium chloride degradation.

    Science.gov (United States)

    Meijide, Jessica; Pazos, Marta; Sanromán, Maria Ángeles

    2017-10-15

    The application of the electro-Fenton process for organic compound mineralisation has been widely reported over the past years. However, operational problems related to the use of soluble iron salt as a homogeneous catalyst involve the development of novel catalysts that are able to operate in a wide pH range. For this purpose, polyvinyl alcohol-alginate beads, containing goethite as iron, were synthesised and evaluated as heterogeneous electro-Fenton catalyst for 1-butylpyridinium chloride mineralisation. The influence of catalyst dosage and pH solution on ionic liquid degradation was analysed, achieving almost total oxidation after 60 min under optimal conditions (2 g/L catalyst concentration and pH 3). The results showed good catalyst stability and reusability, although its effectiveness decreases slightly after three successive cycles. Furthermore, a plausible mineralisation pathway was proposed based on the oxidation byproducts determined by chromatographic techniques. Finally, the Microtox® test revealed notable detoxification after treatment which demonstrates high catalyst ability for pyridinium-based ionic liquid degradation by the electro-Fenton process.

  13. Novel bio-electro-Fenton technology for azo dye wastewater treatment using microbial reverse-electrodialysis electrolysis cell

    DEFF Research Database (Denmark)

    Li, Xiaohu; Jin, Xiangdan; Zhao, Nannan

    2017-01-01

    Development of sustanaible technologies for treatment of azo dyes containing wastewaters has long been of great interest. In this study, we proposed an innovative concept of using microbial reverse-electrodialysis electrolysis cell (MREC) based Fenton process to treat azo dye wastewater. In such ......Development of sustanaible technologies for treatment of azo dyes containing wastewaters has long been of great interest. In this study, we proposed an innovative concept of using microbial reverse-electrodialysis electrolysis cell (MREC) based Fenton process to treat azo dye wastewater....... In such MREC-Fenton integrated process, the production of H2O2 which is the key reactant of fenton-reaction was driven by the electrons harvested from the exoelectrogens and salinity-gradient between sea water and fresh water in MREC. Complete decolorization and mineralization of 400 mg L-1 Orange G...

  14. INTEGRAL/JEM-X detection of fading emission from GT Mus

    DEFF Research Database (Denmark)

    Fiocchi, M.; Chenevez, J.; Sguera, V.

    2015-01-01

    On November 15th 2015 the MAXI/GSC detected a big flare from the RS CVn star GT Mus with a flux of ~100 mCrab in the 2-20 keV energy band. (ATel #8285). During recent INTEGRAL observations of the Musca region performed between 17 Nov 16:08 and 18 Nov 00:05 (UTC) the source GT Mus was within the f...

  15. A review on the degradation of organic pollutants in waters by UV photoelectro-Fenton and solar photoelectro-Fenton

    OpenAIRE

    Brillas, Enric

    2014-01-01

    This paper presents a review on emerging electrochemical advanced oxidation processes (EAOPs) such as UV photoelectro-Fenton (PEF) and solar photoelectro-Fenton (SPEF) in which the irradiation of the effluent with UV light and sunlight, respectively, causes a synergistic effect on the degradation process of organic pollutants by the formation of more •OH and/or the photolysis of complexes of Fe(III) with generated carboxylic acids. Fundamentals of these EAOPs are explained to clarify their pe...

  16. Coupling Fenton and biological oxidation for the removal of nitrochlorinated herbicides from water.

    Science.gov (United States)

    Sanchis, S; Polo, A M; Tobajas, M; Rodriguez, J J; Mohedano, A F

    2014-02-01

    The combination of Fenton and biological oxidation for the removal of the nitrochlorinated herbicides alachlor, atrazine and diuron in aqueous solution has been studied. The H2O2 dose was varied from 20 to 100% of the stoichiometric amount related to the initial chemical oxygen demand (COD). The effluents from Fenton oxidation were analyzed for ecotoxicity, biodegradability, total organic carbon (TOC), COD and intermediate byproducts. The chemical step resulted in a significant improvement of the biodegradability in spite of its negligible or even slightly negative effect on the ecotoxicity. Working at 60% of the stoichiometric H2O2 dose allowed obtaining highly biodegradable effluents in the cases of alachlor and atrazine. That dose was even lower (40% of the stoichiometric) for diuron. The subsequent biological treatment was carried out in a sequencing batch reactor (SBR) and the combined Fenton-biological treatment allowed up to around 80% of COD reduction. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Photo-catalytic degradation of an oil-water emulsion using the photo-fenton treatment process: effects and statistical optimization.

    Science.gov (United States)

    Tony, Maha A; Purcell, P J; Zhao, Y Q; Tayeb, A M; El-Sherbiny, M F

    2009-02-01

    The application of advanced oxidation processes (AOPs) to the treatment of an effluent contaminated with hydrocarbon oils was investigated. The AOPs conducted were Fe2+/H2O2 (Fenton's reagent), Fe2+/H2O2/UV (Photo-Fenton's reagent) and UV-photolysis. These technologies utilize the very strong oxidizing power of hydroxyl radicals to oxidize organic compounds to harmless end products such as CO2 and H2O. A synthetic wastewater generated by emulsifying diesel oil and water was used. This wastewater might simulate, for example, a waste resulting from a hydrocarbon oil spill, onto which detergent was sprayed. The experiments utilising the Photo-Fenton treatment method with an artificial UV source, coupled with Fenton's reagent, suggest that the hydrocarbon oil is readily degradable, but that the emulsifying agent is much more resistant to degradation. The results showed that the COD (chemical oxygen demand) removal rate was affected by the Photo-Fenton parameters (Fe2+, H2O2 concentrations and the initial pH) of the aqueous solution. In addition, the applicability of the treatment method to a 'real' wastewater contaminated with hydrocarbon oil is demonstrated. The 'real' wastewater was sourced at a nearby car-wash facility located at a petroleum filling station and the experimental results demonstrate the effectiveness of the treatment method in this case. A statistical analysis of the experimental data using the Statistical Analysis System (SAS) and the response surface methodology (RSM) based on the experimental design was applied to optimize the Photo-Fenton parameters (concentrations of Fe2+, H2O2 and initial pH) and to maximize the COD removal rate (more than 70%).

  18. A highly energy-efficient flow-through electro-Fenton process for organic pollutants degradation

    International Nuclear Information System (INIS)

    Ma, Liang; Zhou, Minghua; Ren, Gengbo; Yang, Weilu; Liang, Liang

    2016-01-01

    Highlights: • A highly energy-efficient flow-through electro-Fenton reactor was designed. • It had high H 2 O 2 yield and low energy consumption for organic pollutants degradation. • The effect of operational parameters was optimized and possible process mechanism was studied. • The novel system performed wide practicability and potential for organic pollutants degradation. - Abstract: A highly energy-efficient flow-through Electro-Fenton (E-Fenton) reactor for oxidation of methylene blue (MB) from aqueous solution was designed using a perforated DSA as anode and the graphite felt modified by carbon black and polytetrafluoroethylene (PTFE) as cathode for the in situ generation of H 2 O 2 . The modified cathode had a high H 2 O 2 production with low energy consumption, which was characterized by scanning electron microscopy (SEM), nitrogen adsorption-desorption study and contact angle. The flow-through E-Fenton system was compared to the flow-by and regular one, and confirmed to be best on MB removal and TOC degradation. The operational parameters such as current density, pH, Fe 2+ concentration and flow rate were optimized. The MB and TOC removal efficiency of the effluents could keep above 90% and 50%, respectively, and the energy consumption was 23.0 kWh/kgTOC at the current density of 50 mA, pH 3, 0.3 mM Fe 2+ , and the flow rate of 7 mL/min. ·OH was proved to be the main oxidizing species in this system. After 5 times operation, the system, especially cathode, still showed good stability. Five more organic pollutants including orange II (OG), tartrazine, acetylsalicylic acid (ASA), tetracycline (TC) and 2,4-dichlorophen (2,4-DCP) were investigated and the electric energy consumption (EEC) was compared with literatures. All results demonstrated that this flow-through E-Fenton system was energy-efficient and potential for degradation of organic pollutants.

  19. Using single-chamber microbial fuel cells as renewable power sources of electro-Fenton reactors for organic pollutant treatment

    KAUST Repository

    Zhu, Xiuping; Logan, Bruce E.

    2013-01-01

    accomplish H2O2 generation and Fe2+ release for the Fenton reaction. In tests using phenol, 75±2% of the total organic carbon (TOC) was removed in the electro-Fenton reactor in one cycle (22h), and phenol was completely degraded to simple and readily

  20. Development of a trickle bed reactor of electro-Fenton process for wastewater treatment.

    Science.gov (United States)

    Lei, Yangming; Liu, Hong; Shen, Zhemin; Wang, Wenhua

    2013-10-15

    To avoid electrolyte leakage and gas bubbles in the electro-Fenton (E-Fenton) reactors using a gas diffusion cathode, we developed a trickle bed cathode by coating a layer composed of carbon black and polytetrafluoroethylene (C-PTFE) onto graphite chips instead of carbon cloth. The trickle bed cathode was optimized by single-factor and orthogonal experiments, in which carbon black, PTFE, and a surfactant were considered as the determinant of the performance of graphite chips. In the reactor assembled by the trickle bed cathode, H2O2 was generated with a current of 0.3A and a current efficiency of 60%. This performance was attributed to the fine distribution of electrolyte and air, as well as the effective oxygen transfer from the gas phase to the electrolyte-cathode interface. In terms of H2O2 generation and current efficiency, the developed trickle bed reactor had a performance comparable to that of the conventional E-Fenton reactor using a gas diffusion cathode. Further, 123 mg L(-1) of reactive brilliant red X-3B in aqueous solution was decomposed in the optimized trickle bed reactor as E-Fenton reactor. The decolorization ratio reached 97% within 20 min, and the mineralization reached 87% within 3h. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Comparison of Raw Acceleration from the GENEA and ActiGraph™ GT3X+ Activity Monitors

    Directory of Open Access Journals (Sweden)

    Dinesh John

    2013-10-01

    Full Text Available Purpose: To compare raw acceleration output of the ActiGraph™ GT3X+ and GENEA activity monitors. Methods: A GT3X+ and GENEA were oscillated in an orbital shaker at frequencies ranging from 0.7 to 4.0 Hz (ten 2-min trials/frequency on a fixed radius of 5.08 cm. Additionally, 10 participants (age = 23.8 ± 5.4 years wore the GT3X+ and GENEA on the dominant wrist and performed treadmill walking (2.0 and 3.5 mph and running (5.5 and 7.5 mph and simulated free-living activities (computer work, cleaning a room, vacuuming and throwing a ball for 2-min each. A linear mixed model was used to compare the mean triaxial vector magnitude (VM from the GT3X+ and GENEA at each oscillation frequency. For the human testing protocol, random forest machine-learning technique was used to develop two models using frequency domain (FD and time domain (TD features for each monitor. We compared activity type recognition accuracy between the GT3X+ and GENEA when the prediction model was fit using one monitor and then applied to the other. Z-statistics were used to compare the proportion of accurate predictions from the GT3X+ and GENEA for each model. Results: GENEA produced significantly higher (p < 0.05, 3.5 to 6.2% mean VM than GT3X+ at all frequencies during shaker testing. Training the model using TD input features on the GENEA and applied to GT3X+ data yielded significantly lower (p < 0.05 prediction accuracy. Prediction accuracy was not compromised when interchangeably using FD models between monitors. Conclusions: It may be inappropriate to apply a model developed on the GENEA to predict activity type using GT3X+ data when input features are TD attributes of raw acceleration.

  2. Solar photo-Fenton optimisation in treating carbofuran-contaminated water

    Directory of Open Access Journals (Sweden)

    Manuel Alejandro Hernández-Shek

    2012-01-01

    Full Text Available Box-Benkhen design response-surface methodology was developed to optimise photo-Fenton degradation of carbofuran (C12H15NO3 by using a compound parabolic collector pilot plant. The four variables considered in Box-Benkhen design model included carbofuran degradation percentage, initial carbofuran concentration, hydrogen peroxide [H2O2] concentration and iron [Fe2+] concentration. Degradation was monitored by using total organic carbon concentration and high-performance liquid chromatography. A 93.2 mg l-1 carbofuran concentration was completely degraded in t30W = 15 min with 17.1 mg l-1 Fe2+ and 121.6 mg l-1 H2O2. Photo-Fenton degradation led to 76.7% mineralisation. Biodegradability during optimisation was evaluated by using the BOD5/COD ratio; this value increased from 0.04 at the beginning of the process to 0.52 in t30W = 20 min, thereby showing the effectiveness of using biological treatments.

  3. Tests of Hadronic Probes of GT Strength

    CERN Multimedia

    2002-01-01

    There are many important problems where one wishes to know the distribution of Gamow-Teller (GT) strength in circumstances where it cannot be measured directly (for example, because of energy-release limitations). Then one must rely on hadronic probes to infer the GT strength. It is therefore essential to test these probes as extensively as possible. The isospin-analog transitions in $^{37}$Ca $\\beta^{+}$ -decay and $^{37}$Cl$(p, n)$ provide an excellent ground for such a test. Recent $^{37}$Cl$ (p, n) $ studies, while qualitatively in agreement with our previous ISOLDE work on $^{37}$Ca $\\beta^{+} $ -decay, show quantitative discrepancies that appear to grow as the excitation energy in the residual nuclei increases. Because of the bulk of the GT strengh appears at these high excitation energies, it is important to extend the $\\beta$-decay data to even higher excitation energies where, because of rapidly diminishing phase-space, strong GT transitions correspond to very weak $\\beta$ -branches. We propose to do...

  4. Synergetic pretreatment of waste activated sludge by hydrodynamic cavitation combined with Fenton reaction for enhanced dewatering.

    Science.gov (United States)

    Cai, Meiqiang; Hu, Jianqiang; Lian, Guanghu; Xiao, Ruiyang; Song, Zhijun; Jin, Micong; Dong, Chunying; Wang, Quanyuan; Luo, Dewen; Wei, Zongsu

    2018-04-01

    The dewatering of waste activated sludge by integrated hydrodynamic cavitation (HC) and Fenton reaction was explored in this study. We first investigated the effects of initial pH, sludge concentration, flow rate, and H 2 O 2 concentration on the sludge dewaterability represented by water content, capillary suction time and specific resistance to filtration. The results of dewatering tests showed that acidic pH and low sludge concentration were favorable to improve dewatering performance in the HC/Fenton system, whereas optimal flow rate and H 2 O 2 concentration applied depended on the system operation. To reveal the synergism of HC/Fenton treatment, a suite of analysis were implemented: three-dimensional excitation emission matrix (3-DEEM) spectra of extracellular polymeric substances (EPS) such as proteins and polysaccharides, zeta potential and particle size of sludge flocs, and SEM/TEM imaging of sludge morphology. The characterization results indicate a three-step mechanism, namely HC fracture of different EPS in sludge flocs, Fenton oxidation of the released EPS, and Fe(III) re-flocculation, that is responsible for the synergistically enhanced sludge dewatering. Results of current study provide a basis to improve our understanding on the sludge dewatering performance by HC/Fenton treatment and possible scale-up of the technology for use in wastewater treatment plants. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Degradation of carbendazim in water via photo-Fenton in Raceway Pond Reactor: assessment of acute toxicity and transformation products.

    Science.gov (United States)

    da Costa, Elizângela Pinheiro; Bottrel, Sue Ellen C; Starling, Maria Clara V M; Leão, Mônica M D; Amorim, Camila Costa

    2018-05-08

    This study aimed at investigating the degradation of fungicide carbendazim (CBZ) via photo-Fenton reactions in artificially and solar irradiated photoreactors at laboratory scale and in a semi-pilot scale Raceway Pond Reactor (RPR), respectively. Acute toxicity was monitored by assessing the sensibility of bioluminescent bacteria (Aliivibrio fischeri) to samples taken during reactions. In addition, by-products formed during solar photo-Fenton were identified by liquid chromatography coupled to mass spectrometry (UFLC-MS). For tests performed in lab-scale, two artificial irradiation sources were compared (UV λ > 254nm and UV-Vis λ > 320nm ). A complete design of experiments was performed in the semi-pilot scale RPR in order to optimize reaction conditions (Fe 2+ and H 2 O 2 concentrations, and water depth). Efficient degradation of carbendazim (> 96%) and toxicity removal were achieved via artificially irradiated photo-Fenton under both irradiation sources. Control experiments (UV photolysis and UV-Vis peroxidation) were also efficient but led to increased acute toxicity. In addition, H 2 O 2 /UV λ > 254nm required longer reaction time (60 minutes) when compared to the photo-Fenton process (less than 1 min). While Fenton's reagent achieved high CBZ and acute toxicity removal, its efficiency demands higher concentration of reagents in comparison to irradiated processes. Solar photo-Fenton removed carbendazim within 15 min of reaction (96%, 0.75 kJ L -1 ), and monocarbomethoxyguanidine, benzimidazole isocyanate, and 2-aminobenzimidazole were identified as transformation products. Results suggest that both solar photo-Fenton and artificially irradiated systems are promising routes for carbendazim degradation.

  6. Enhancement of activated sludge disintegration and dewaterability by Fenton process

    Science.gov (United States)

    Heng, G. C.; Isa, M. H.

    2016-06-01

    Municipal and industrial wastewater treatment plants produce large amounts of sludge. This excess sludge is an inevitable drawback inherent to the activated sludge process. In this study, the waste activated sludge was obtained from the campus wastewater treatment plant at Universiti Teknologi PETRONAS (UTP), Malaysia. Fenton pretreatment was optimized by using the response surface methodology (RSM) to study the effects of three operating conditions including the dosage of H2O2 (g H2O2/kg TS), the molar ratio of H2O2/Fe2+ and reaction time. The optimum operating variables to achieve MLVSS removal 65%, CST reduction 28%, sCOD 11000 mg/L and EPS 500 mg/L were: 1000 g H2O2/kg TS, H2O2/Fe2+ molar ratio 70 and reaction time 45 min. Fenton process was proved to be able to enhance the sludge disintegration and dewaterability.

  7. Coagulation-Fenton coupled treatment for ecotoxicity reduction in highly polluted industrial wastewater.

    Science.gov (United States)

    Perdigón-Melón, J A; Carbajo, J B; Petre, A L; Rosal, R; García-Calvo, E

    2010-09-15

    A coupled coagulation-Fenton process was applied for the treatment of cosmetic industry effluents. In a first step, FeSO(4) was used as coagulant and the non-precipitated Fe(2+) remaining in dissolution was used as catalyst in the further Fenton process. In the coagulation process a huge decrease in total organic carbon (TOC) was achieved, but the high concentration of phenol derivatives was not diminished. The decrease in TOC in the coagulation step significantly reduces the amount of H(2)O(2) required in the Fenton process for phenol depletion. The coupled process, using a H(2)O(2) dose of only 2 g l(-1), reduced TOC and total phenol to values lower than 40 and 0.10 mg l(-1), respectively. The short reaction period (less than 15 min) in TOC and phenol degradation bodes well for improving treatment in a continuous regime. The combination of both processes significantly reduced the ecotoxicity of raw effluent and markedly increased its biodegradability, thus allowing easier treatment by the conventional biological units in conventional sewage treatment plants (STPs). Copyright 2010 Elsevier B.V. All rights reserved.

  8. FENTON-DRIVEN REGENERATION OF GRANULAR ACTIVATED CARBON: A TECHNOLOGY OVERVIEW

    Science.gov (United States)

    A Fenton-driven mechanism for regenerating spent granular activated carbon (GAC) involves the combined, synergistic use of two reliable and well established treatment technologies - adsorption onto activated carbon and Fenton oxidation. During carbon adsorption treatment, enviro...

  9. The photodeposition of surface plasmon Ag metal on SiO2@α-Fe2O3 nanocomposites sphere for enhancement of the photo-Fenton behavior

    Science.gov (United States)

    Uma, Kasimayan; Arjun, Nadarajan; Pan, Guan-Ting; Yang, Thomas C.-K.

    2017-12-01

    In this study, a simple sol-gel method was used for the synthesis of a core-shell structure of SiO2@α-Fe2O3 nanocomposites for employment as a visible light photocatalyst. It was observed that Ag nanoparticles about 20 nm in size were successfully deposited on the surface of the SiO2@α-Fe2O3 nanocomposites. The photocatalytic activity of the Ag-SiO2@α-Fe2O3 nanocomposites catalyst was investigated by observing the degradation of methylene blue (MB) dye in a photo-Fenton process. The results showed that the Ag nanoparticles acted as centers for photo induced electron transfer. The catalytic activity in the SiO2@α-Fe2O3 nanocomposites were enhanced due to the plasmoni c effect of Ag metal under visible light irradiation. The addition of H2O2 played an important role, generating more OH radicals which improved the photo-Fenton catalytic activity, resulting in quicker degradation of the MB dye using the Ag-SiO2@α-Fe2O3 nanocomposite catalyst.

  10. GT-MHR design, performance, and safety

    International Nuclear Information System (INIS)

    Neylan, A.J.; Shenoy, A.; Silady, F.A.; Dunn, T.D.

    1994-11-01

    The Gas Turbine-Modular Helium Reactor (GT-MHR) is the result of coupling the evolution of a low power density passively safe modular reactor with key technology developments in the U.S. during the last decade: large industrial gas turbines; large active magnetic bearings; and compact, highly effective plate-fin heat exchangers. This is accomplished through the unique use of the Brayton cycle to produce electricity with the helium as primary coolant from the reactor directly driving the gas turbine electrical generator. This cycle can achieve a high net efficiency in the range of 45% to 48%. In the design of the GT-MHR the desirable inherent characteristics of the inert helium coolant, graphite core, and the coated fuel particles are supplemented with specific design features such as passive heat removal to achieve the safety objective of not disturbing the normal day-to-day activities of the public even for beyond design basis rare accidents. Each GT-MHR plant consists of four modules. The GT-MHR module components are contained within steel pressure vessels: a reactor vessel, a power conversion vessel, and a connecting cross vessel. All vessels are sited underground in a concrete silo, which serves as an independent vented low pressure containment structure. By capitalizing on industrial and aerospace gas turbine development, highly effective heat exchanger designs, and inherent gas cooled reactor temperature characteristics, the passively safe GT-MHR provides a sound technical, monetary, and environmental basis for new nuclear power generating capacity. This paper provides an update on the status of the design, which has been under development on the US-DOE program since February 1993. An assessment of plant performance and safety is also included

  11. Electrochemical destruction of chlorophenoxy herbicides by anodic oxidation and electro-Fenton using a boron-doped diamond electrode

    International Nuclear Information System (INIS)

    Brillas, Enric; Boye, Birame; Sires, Ignasi; Garrido, Jose Antonio; Rodriguez, Rosa Maria; Arias, Conchita; Cabot, Pere-Lluis; Comninellis, Christos

    2004-01-01

    The degradation of herbicides 4-chlorophenoxyacetic acid (4-CPA), 4-chloro-2-methylphenoxyacetic acid (MCPA), 2,4-dichlorophenoxyacetic acid (2,4-D) and 2,4,5-trichlorophenoxyacetic acid (2,4,5-T) in aqueous medium of pH 3.0 has been comparatively studied by anodic oxidation and electro-Fenton using a boron-doped diamond (BDD) anode. All solutions are totally mineralized by electro-Fenton, even at low current, being the process more efficient with 1 mM Fe 2+ as catalyst. This is due to the production of large amounts of oxidant hydroxyl radical (OH·) on the BDD surface by water oxidation and from Fenton's reaction between added Fe 2+ and H 2 O 2 electrogenerated at the O 2 -diffusion cathode. The herbicide solutions are also completely depolluted by anodic oxidation. Although a quicker degradation is found at the first stages of electro-Fenton, similar times are required for achieving overall mineralization in both methods. The decay kinetics of all herbicides always follows a pseudo first-order reaction. Reversed-phase chromatography allows detecting 4-chlorophenol, 4-chloro-o-cresol, 2,4-dichlorophenol and 2,4,5-trichlorophenol as primary aromatic intermediates of 4-CPA, MCPA, 2,4-D and 2,4,5-T, respectively. Dechlorination of these products gives Cl - , which is slowly oxidized on BDD. Ion-exclusion chromatography reveals the presence of persistent oxalic acid in electro-Fenton by formation of Fe 3+ -oxalato complexes, which are slowly destroyed by OH· adsorbed on BDD. In anodic oxidation, oxalic acid is mineralized practically at the same rate as generated

  12. Reactivity of catecholamine-driven Fenton reaction and its relationships with iron(III) speciation.

    Science.gov (United States)

    Melin, Victoria; Henríquez, Adolfo; Freer, Juanita; Contreras, David

    2015-03-01

    Fenton reaction is the main source of free radicals in biological systems. The reactivity of this reaction can be modified by several factors, among these iron ligands are important. Catecholamine (dopamine, epinephrine, and norepinephrine) are able to form Fe(III) complexes whose extension in the coordination number depends upon the pH. Fe(III)-catecholamine complexes have been related with the development of several pathologies. In this work, the ability of catecholamines to enhance the oxidative degradation of an organic substrate (veratryl alcohol, VA) through Fenton and Fenton-like reactions was studied. The initial VA degradation rate at different pH values and its relationship to the different iron species present in solution were determined. Furthermore, the oxidative degradation of VA after 24 hours of reaction and its main oxidation products were also determined. The catecholamine-driven Fenton and Fenton-like systems showed higher VA degradation compared to unmodified Fenton or Fenton-like systems, which also showed an increase in the oxidation state of the VA degradation product. All of this oxidative degradation takes place at pH values lower than 5.50, where the primarily responsible species would be the Fe(III) mono-complex. The presence of Fe(III) mono-complex is essential in the ability of catecholamines to increase the oxidative capacity of Fenton systems.

  13. Integrating Fenton's process and ion exchange for olive mill wastewater treatment and iron recovery.

    Science.gov (United States)

    Reis, Patrícia M; Martins, Pedro J M; Martins, Rui C; Gando-Ferreira, Licínio M; Quinta-Ferreira, Rosa M

    2018-02-01

    A novel integrated methodology involving Fenton's process followed by ion exchange (IE) was proposed for the treatment of olive mill wastewater. Fenton's process was optimized and it was able to remove up to 81% of chemical oxygen demand when pH 3.5, reaction time 1 h, [Fe 2+ ] = 50 mg L -1 and [Fe 2+ ]/[H 2 O 2 ] = 0.002 were applied. In spite of the potential of this treatment approach, final iron removal from the liquid typically entails pH increase and iron sludge production. The integration of an IE procedure using Lewatit TP 207 resin was found to be able to overcome this important environmental shortcoming. The resin showed higher affinity toward Fe 3+ than to Fe 2+ . However, the iron removal efficiency of an effluent coming from Fenton's was independent of the type of the initial iron used in the process. The presence of organic matter had no significant effect over the resin iron removal efficiency. Even if some efficiency decrease was observed when a high initial iron load was applied, the adsorbent mass quantity can be easily adapted to reach the desired iron removal. The use of IE is an interesting industrial approach able to surpass Fenton's peroxidation drawback and will surely boost its full-scale application in the treatment of bio-refractory effluents.

  14. Fenton process-affected transformation of roxarsone in paddy rice soils: Effects on plant growth and arsenic accumulation in rice grain.

    Science.gov (United States)

    Qin, Junhao; Li, Huashou; Lin, Chuxia

    2016-08-01

    Batch and greenhouse experiments were conducted to examine the effects of Fenton process on transformation of roxarsone in soils and its resulting impacts on the growth of and As uptake by a rice plant cultivar. The results show that addition of Fenton reagent markedly accelerated the degradation of roxarsone and produced arsenite, which was otherwise absent in the soil without added Fenton reagent. Methylation of arsenate was also enhanced by Fenton process in the earlier part of the experiment due to abundant supply of arsenate from Roxarsone degradation. Overall, addition of Fenton reagent resulted in the predominant presence of arsenate in the soils. Fenton process significantly improved the growth of rice in the maturity stage of the first crop, The concentration of methylated As species in the rice plant tissues among the different growth stages was highly variable. Addition of Fenton reagent into the soils led to reduced uptake of soil-borne As by the rice plants and this had a significant effect on reducing the accumulation of As in rice grains. The findings have implications for understanding As biogeochemistry in paddy rice field receiving rainwater-borne H2O2 and for development of mitigation strategies to reduce accumulation of As in rice grains. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Degradation of azo dyes by sequential Fenton's oxidation and aerobic biological treatment

    International Nuclear Information System (INIS)

    Tantak, Nilesh P.; Chaudhari, Sanjeev

    2006-01-01

    A two stage sequential Fenton's oxidation followed by aerobic biological treatment train was used to achieve decolorization and to enhance mineralization of azo dyes, viz. Reactive Black 5 (RB5), Reactive Blue 13 (RB13), and Acid Orange 7 (AO7). In the first stage, Fenton's oxidation process was used while in the second stage aerobic sequential batch reactors (SBRs) were used as biological process. Study was done to evaluate effect of pH on Fenton's oxidation process. Results reveal that pH 3 was optimum pH for achieving decolorization and dearomatization of dyes by Fenton's process. Degradation of dye was assessed by COD reduction and reduction in aromatic amines (naphthalene chromophores) which was measured by reduction in absorbance at 200 nm. More than 95% of color was removed with Fenton's oxidation process in all dyes. In overall treatment train 81.95, 85.57, and 77.83% of COD reduction was achieved in RB5, RB13, and AO7 dyes, respectively. In the Fenton's oxidation process 56, 24.5, and 80% reduction in naphthalene group was observed in RB5, RB13, and AO7, respectively, which further increased to 81.34, 68.73, and 92% after aerobic treatment. Fenton's oxidation process followed by aerobic SBRs treatment sequence seems to be viable method for achieving significant degradation of azo dye

  16. Rapid and facile preparation of zinc ferrite (ZnFe{sub 2}O{sub 4}) oxide by microwave-solvothermal technique and its catalytic activity in heterogeneous photo-Fenton reaction

    Energy Technology Data Exchange (ETDEWEB)

    Anchieta, Chayene G.; Severo, Eric C.; Rigo, Caroline; Mazutti, Marcio A. [Department of Chemical Engineering, Federal University of Santa Maria, 97105-900, Santa Maria (Brazil); Kuhn, Raquel C., E-mail: raquelckuhn@yahoo.com.br [Department of Chemical Engineering, Federal University of Santa Maria, 97105-900, Santa Maria (Brazil); Muller, Edson I.; Flores, Erico M.M. [Department of Chemistry, Federal University of Santa Maria, 97105-900, Santa Maria (Brazil); Moreira, Regina F.P.M. [Department of Chemical Engineering and Food Engineering, Federal University of Santa Catarina, 88040-970, Florianópolis (Brazil); Foletto, Edson L. [Department of Chemical Engineering, Federal University of Santa Maria, 97105-900, Santa Maria (Brazil)

    2015-06-15

    In this work zinc ferrite (ZnFe{sub 2}O{sub 4}) oxide was rapidly and easily prepared by microwave-solvothermal route and its catalytic property in photo-Fenton reaction was evaluated. The effects of microwave heating time and power on the properties of produced particles were investigated. X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), atomic force microscopy (AFM) and nitrogen adsorption–desorption isotherms were the techniques used for characterizing the solid products. The synthesized material was tested as a catalyst in the degradation of the textile dye molecule by the heterogeneous photo-Fenton process. Characterization results showed that the microwave heating time and power have significant influences on the formation of the phase spinel as well as on its physical properties. The reaction results showed that the ZnFe{sub 2}O{sub 4} oxide has good photocatalytic activity, which can be attributed to high surface area and pore volume, and large pore size. The ZnFe{sub 2}O{sub 4} oxide produced by the microwave irradiation exhibited promising photocatalytic activity for the removal of textile dye, reaching nearly 100% of decolorization at 40 min and 60% of mineralization at 240 min. Therefore, ZnFe{sub 2}O{sub 4} particles rapidly prepared by the microwave route have the potential for use in treatment of textile wastewater by the heterogeneous photo-Fenton process. - Highlights: • ZnFe{sub 2}O{sub 4} was synthesized by microwave-solvothermal method. • ZnFe{sub 2}O{sub 4} was prepared by different microwave heating times and powers. • ZnFe{sub 2}O{sub 4} was used as heterogeneous photo-Fenton catalyst. • Degradation of Procion red dye using heterogeneous photo-Fenton process. • ZnFe{sub 2}O{sub 4} was highly efficient to degrade textile dye under visible light.

  17. Fenton oxidation treatment of spent wash-off liquor for reuse in reactive dying

    International Nuclear Information System (INIS)

    Mangat, A.; Shaikh, I.A.; Ahmed, F.; Baqar, M

    2014-01-01

    The use of clean and high quality water in textile dyeing process is very expensive. In this study, the potential of reusing Fenton treated wash-off wastewater generated at the end of reactive dyeing was investigated. The treated wastewater was used in several dyeings employing three widely used reactive dyes, C. I. Reactive Yellow 145, C. I. Reactive Red 194, and C. I. Reactive Blue 221. Experimental results showed that at acidic pH (3.5) using optimized quantities of FeSO/sub 4/ and H/sub 2/O/sub 2/, Fenton process yielded a significant reduction (80-99%) of colour and COD in 30 minutes of treatment time. New dyeings were then carried out in Fenton decolourized wash-off wastewater, and dyed fabric samples were subjected to quality evaluations in terms of wash fastness, crock fastness, and colour difference properties (delta L*, delta c*, delta h*, and delta E*). This study concluded that Fenton oxidation was an efficient method for the treatment of textile wash-off wastewater, and treated liquor can be effectively recycled in next dyeing, without compromising quality parameters. This method proved to be an eco-friendly process owing to the fact that it did not use any fresh water. (author)

  18. Sequential application of Fenton and ozone-based oxidation process for the abatement of Ni-EDTA containing nickel plating effluents.

    Science.gov (United States)

    Zhao, Zilong; Liu, Zekun; Wang, Hongjie; Dong, Wenyi; Wang, Wei

    2018-07-01

    Treatment of Ni-EDTA in industrial nickel plating effluents was investigated by integrated application of Fenton and ozone-based oxidation processes. Determination of integrated sequence found that Fenton oxidation presented higher apparent kinetic rate constant of Ni-EDTA oxidation and capacity for contamination load than ozone-based oxidation process, the latter, however, was favorable to guarantee the further mineralization of organic substances, especially at a low concentration. Serial-connection mode of two oxidation processes was appraised, Fenton effluent after treated by hydroxide precipitation and filtration negatively affected the overall performance of the sequential system, as evidenced by the removal efficiencies of Ni 2+ and TOC dropping from 99.8% to 98.7%, and from 74.8% to 66.6%, respectively. As a comparison, O 3 /Fe 2+ oxidation process was proved to be more effective than other processes (e.g. O 3 -Fe 2+ , O 3 /H 2 O 2 /Fe 2+ , O 3 /H 2 O 2 -Fe 2+ ), and the final effluent Ni 2+ concentration could satisfied the discharge standard (Fenton reaction, initial influent pH of 3.0, O 3 dosage of 252 mg L -1 , Fe 2+ of 150 mg L -1 , and reaction time of 30 min for O 3 /Fe 2+ oxidation). Furthermore, pilot-scale test was carried out to study the practical treatability towards the real nickel plating effluent, revealing the effective removal of some other co-existence contaminations. And Fenton reaction has contributed most, with the percentage ranging from 72.41% to 93.76%. The economic cost advantage made it a promising alternative to the continuous Fenton oxidation. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Involvement of Fenton chemistry in rice straw degradation by the lignocellulolytic bacterium Pantoea ananatis Sd-1.

    Science.gov (United States)

    Ma, Jiangshan; Zhang, Keke; Huang, Mei; Hector, Stanton B; Liu, Bin; Tong, Chunyi; Liu, Qian; Zeng, Jiarui; Gao, Yan; Xu, Ting; Liu, Ying; Liu, Xuanming; Zhu, Yonghua

    2016-01-01

    Lignocellulolytic bacteria have revealed to be a promising source for biofuel production, yet the underlying mechanisms are still worth exploring. Our previous study inferred that the highly efficient lignocellulose degradation by bacterium Pantoea ananatis Sd-1 might involve Fenton chemistry (Fe 2+  + H 2 O 2  + H +  → Fe 3+  + OH· + H 2 O), similar to that of white-rot and brown-rot fungi. The aim of this work is to investigate the existence of this Fenton-based oxidation mechanism in the rice straw degradation process of P. ananatis Sd-1. After 3 days incubation of unpretreated rice straw with P. ananatis Sd-1, the percentage in weight reduction of rice straw as well as its cellulose, hemicellulose, and lignin components reached 46.7, 43.1, 42.9, and 37.9 %, respectively. The addition of different hydroxyl radical scavengers resulted in a significant decline ( P  Fenton reagent treatment. In addition to the increased total iron ion concentration throughout the rice straw decomposition process, the Fe 3+ -reducing capacity of P. ananatis Sd-1 was induced by rice straw and predominantly contributed by aromatic compounds metabolites. The transcript levels of the glucose-methanol-choline oxidoreductase gene related to hydrogen peroxide production were significantly up-regulated (at least P  Fenton-like reactions. Our results confirmed the Fenton chemistry-assisted degradation model in P. ananatis Sd-1. We are among the first to show that a Fenton-based oxidation mechanism exists in a bacteria degradation system, which provides a new perspective for how natural plant biomass is decomposed by bacteria. This degradative system may offer an alternative approach to the fungi system for lignocellulosic biofuels production.

  20. Fenton-driven regeneration of MTBE-spent granular activated carbon - Effects of particle size and Iron Amendment Procedures

    Science.gov (United States)

    Fenton-driven regeneration of spent granular activated carbon (GAC) is a technology being developed to regenerate organic contaminant-spent GAC. Here, the effect of GAC particle size (>2 mm to Fenton-driven oxidation of methyl tert-butyl ether (MTBE)-spent GAC was ev...

  1. Evaluation of adsorption and Fenton-adsorption processes for landfill leachate treatment

    OpenAIRE

    San Pedro-Cedillo, L.; Méndez-Novelo, R.I.; Rojas-Valencia, M.N.; Barceló-Quintal, M.; Castillo-Borges, E.R.; Sauri-Riancho, M.R.; Marrufo-Gómez, J.M.

    2015-01-01

    The objective of this research was to compare the adsorption and Fenton-adsorption treatments for the removal of contaminants in leachate from landfills and thus determine the most efficient one. The adsorption process with granular activated carbon was tested in two types of samples: raw leachate and leachate treated by Fenton. The results showed color, chemical oxygen demand (COD), total nitrogen and total organic carbon (TOC) removal rates higher than 99% through the Fenton-adsorption proc...

  2. Removal of binary dyes mixtures with opposite and similar charges by adsorption, coagulation/flocculation and catalytic oxidation in the presence of CeO2/H2O2 Fenton-like system.

    Science.gov (United States)

    Issa Hamoud, Houeida; Finqueneisel, Gisèle; Azambre, Bruno

    2017-06-15

    In this study, the removal of binary mixtures of dyes with similar (Orange II/Acid Green 25) or opposite charges (Orange II/Malachite Green) was investigated either by simple adsorption on ceria or by the heterogeneous Fenton reaction in presence of H 2 O 2 . First, the CeO 2 nanocatalyst with high specific surface area (269 m 2 /g) and small crystal size (5 nm) was characterized using XRD, Raman spectroscopy and N 2 physisorption at 77 K. The adsorption of single dyes was studied either from thermodynamic and kinetic viewpoints. It is shown that the adsorption of dyes on ceria surface is highly pH-dependent and followed a pseudo-second order kinetic model. Adsorption isotherms fit well the Langmuir model with a complete monolayer coverage and higher affinity towards Orange II at pH 3, compared to other dyes. For the (Orange II/Acid Green 25) mixture, both the amounts of dyes adsorbed on ceria surface and discoloration rates measured from Fenton experiments were decreased by comparison with single dyes. This is due to the adsorption competition existing onto the same surface Ce x+ sites and the reaction competition with hydroxyl radicals, respectively. The behavior of the (Orange II/Malachite Green) mixture is markedly different. Dyes with opposite charges undergo paired adsorption on ceria as well as homogeneous and heterogeneous coagulation/flocculation processes, but can also be removed by heterogeneous Fenton process. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Can mt2 much-gt mb2 arise from small corrections in four-family models

    International Nuclear Information System (INIS)

    Mendel, R.R.; Margolis, B.; Therrien, E.; Valin, P.

    1989-01-01

    This paper proposes a general dynamical scheme capable of explaining naturally the main properties of the observed spectrum, namely the strong inter-family mass hierarchies and the mixing pattern. The authors illustrate these properties in the three-family case with a simple toy model. There is an indication that large values of m t may be required in order to obtain |V by |much-lt|V bc ; the fact the m 2 much-gt m 2 could be due to small corrections in a four-family model where m' ∼ m'. The authors point out possible natural explanations for the small mass of the e, μ and τ neutrinos in the three and four family cases

  4. Using single-chamber microbial fuel cells as renewable power sources of electro-Fenton reactors for organic pollutant treatment

    International Nuclear Information System (INIS)

    Zhu, Xiuping; Logan, Bruce E.

    2013-01-01

    Highlights: ► A new type of electro-Fenton system was developed for wastewater treatment. ► Degradation efficiency of organic pollutants was substantially improved. ► Operation cost was greatly reduced compared to other microbial fuel cell designs. -- Abstract: Electro-Fenton reactions can be very effective for organic pollutant degradation, but they typically require non-sustainable electrical power to produce hydrogen peroxide. Two-chamber microbial fuel cells (MFCs) have been proposed for pollutant treatment using Fenton-based reactions, but these types of MFCs have low power densities and require expensive membranes. Here, more efficient dual reactor systems were developed using a single-chamber MFC as a low-voltage power source to simultaneously accomplish H 2 O 2 generation and Fe 2+ release for the Fenton reaction. In tests using phenol, 75 ± 2% of the total organic carbon (TOC) was removed in the electro-Fenton reactor in one cycle (22 h), and phenol was completely degraded to simple and readily biodegradable organic acids. Compared to previously developed systems based on two-chamber MFCs, the degradation efficiency of organic pollutants was substantially improved. These results demonstrate that this system is an energy-efficient and cost-effective approach for industrial wastewater treatment of certain pollutants

  5. Degradation of 1-butyl-3-methylimidazolium chloride ionic liquid in a Fenton-like system

    International Nuclear Information System (INIS)

    Siedlecka, E.M.; Mrozik, W.; Kaczynski, Z.; Stepnowski, P.

    2008-01-01

    The study examined the usefulness of a Fenton-like system for the degradation of ionic liquid residues in water. The ionic liquid was oxidized in a dilute aqueous solution of 1-butyl-3-methylimidazolium chloride (bmimCl). The ionic liquid decomposes readily and rapidly in aqueous solution by chemical degradation in a Fenton-like system. Under chosen conditions the initial bmimCl solution was reduced by a factor of 0.973 within 90 min. Additional results showed that bmimCl degradations in a Fenton-like system in excess H 2 O 2 could be interpreted as a combined oxidation-reduction mechanism. Preliminary investigations of the mechanism of such degradations have indicated that initial OH· radicals can attack any one of the three carbon atoms on the imidazolium ring. The intermediates of this reaction may be mono- di- or amino- carboxylic acids

  6. Response to Fenton and Fenton: evidence does not support the alkaline diet

    Science.gov (United States)

    In the space available in this broad review, we focused on large trials published since the 2011 Fenton meta-analysis. This included two trials published in 2013 and one in 2015. These trials found favorable effects of supplementation with alkaline salts of potassium, in amounts of 60 mmol/day and h...

  7. Photochemical oxidation of short-chain polychlorinated n-alkane mixtures using H2O2/UV and the photo-Fenton reaction

    OpenAIRE

    Ken J. Friesen; Taha M. El-Morsi; Alaa S. Abd-El-Aziz

    2004-01-01

    The photochemical oxidation of a series of short-chain polychlorinated n-alkane (PCA) mixtures was investigated using H2O2/UV and modified photo-Fenton conditions (Fe3+/H2O2/UV) in both Milli-Q and lake water. All PCA mixtures, including chlorinated (Cl5 to Cl8) decanes, undecanes, dodecanes and tridecanes degraded in 0.02 M H2O2/UV at pH 2.8 in pure water, with 80±4% disappearance after 3 h of irradiation using a 300 nm light source. Degradation was somewhat enhanced under similar conditions...

  8. Advanced Heterogeneous Fenton Treatment of Coalbed Methane-Produced Water Containing Fracturing Fluid

    Directory of Open Access Journals (Sweden)

    Meng Zhang

    2018-04-01

    Full Text Available This study investigated the heterogeneous Fenton treatment to process coalbed methane-produced water containing fracturing fluid and chose the development region of coalbed methane in the Southern Qinshui Basin as a research area. We synthesized the catalyst of Fe-Co/γ-Al2O3 by homogeneous precipitation method and characterized it by BET, XRD, SEM-EDS, FTIR, and XPS. Based on the degradation rate, we studied the influences of the heterogeneous Fenton method on the coalbed methane output water treatment process parameters, including initial pH, H2O2 concentration, and the catalyst concentration. We also investigated the impacts of overall reaction kinetics of heterogeneous catalytic oxidation on coalbed methane-produced water containing fracturing fluid. Results showed that Fe-Co/γ-Al2O3 as a Fenton catalyst has a good catalytic oxidation effect and can effectively process coalbed methane-produced water. This reaction also followed first-order kinetics. The optimal conditions were as follows: the initial pH of 3.5, a H2O2 concentration of 40 mol L−1, a catalyst concentration of 4 g/L, and an apparent reaction rate constant of 0.0172 min−1. Our results provided a basis to establish methods for treating coalbed methane-produced water.

  9. Effect of a solar Fered-Fenton system using a recirculation reactor on biologically treated landfill leachate.

    Science.gov (United States)

    Ye, Zhihong; Zhang, Hui; Yang, Lin; Wu, Luxue; Qian, Yue; Geng, Jinyao; Chen, Mengmeng

    2016-12-05

    The effects of electrochemical oxidation (EO), Fered-Fenton and solar Fered-Fenton processes using a recirculation flow system containing an electrochemical cell and a solar photo-reactor on biochemically treated landfill leachate were investigated. The most successful method was solar Fered-Fenton which achieved 66.5% COD removal after 120min treatment utilizing the optimum operating conditions of 47mM H2O2, 0.29mM Fe(2+), pH0 of 3.0 and a current density of 60mA/cm(2). The generation of hydroxyl radicals (OH) are mainly from Fered-Fenton process, which is enhanced by the introduction of renewable solar energy. Moreover, Fe(2+)/chlorine and UV/chlorine processes taking place in this system also result in additional production of OH due to the relatively high concentration of chloride ions contained in the leachate. The energy consumption was 74.5kWh/kg COD and the current efficiency was 36.4% for 2h treatment. In addition, the molecular weight (MW) distribution analysis and PARAFAC analysis of excitation emission matrix (EEM) fluorescence spectroscopy for different leachate samples indicated that the organics in the leachate were significantly degraded into either small molecular weight species or inorganics. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Improvement of biodegradability of oil wastewater contained PAM by pretreatment with Fenton oxidation

    International Nuclear Information System (INIS)

    Bao, M.; Wang, N.

    2008-01-01

    The use of polymer flooding in enhanced oil recovery operations has resulted in higher levels of polyacrylamide (PAM) found in oil wastewater. PAM is harmful to the environment, particularly the monomer acrylamide that is generated from PAM degradation. In this study, PAM derived from oil wastewater was pretreated by Fenton oxidation. This oxidation method is based on the use of a mixture of H 2 O 2 and iron salts which produce hydroxyl radicals in acidic conditions. The method offers a cost-effective source of hydroxyl radicals, using easy-to-handle reagents. The purpose of this study was to transform PAM to biodegradable intermediums. The optimal conditions for the Fenton reactions were also determined and described. Under optimal conditions, the removal ratios of PAM and chemical oxygen demand (COD) were 83.8 and 77 per cent respectively. It was concluded that Fenton's oxidation is an effective treatment to improved the biodegradability of PAM. 14 refs., 1 tab., 7 figs

  11. Decolourisation of dyes under electro-Fenton process using Fe alginate gel beads

    International Nuclear Information System (INIS)

    Rosales, E.; Iglesias, O.; Pazos, M.; Sanromán, M.A.

    2012-01-01

    Highlights: ► Catalytic activity of Fe alginate gel beads for the remediation of wastewater was tested. ► New electro-Fenton process for the remediation of polluted wastewater. ► Continuous dye treatment without operational problem with high removal. - Abstract: This study focuses on the application of electro-Fenton technique by use of catalytic activity of Fe alginate gel beads for the remediation of wastewater contaminated with synthetic dyes. The Fe alginate gel beads were evaluated for decolourisation of two typical dyes, Lissamine Green B and Azure B under electro-Fenton process. After characterization of Fe alginate gel beads, the pH effect on the process with Fe alginate beads and a comparative study of the electro-Fenton process with free Fe and Fe alginate bead was done. The results showed that the use of Fe alginate beads increases the efficiency of the process; moreover the developed particles show a physical integrity in a wide range of pH (2–8). Around 98–100% of dye decolourisation was obtained for both dyes by electro-Fenton process in successive batches. Therefore, the process was performed with Fe alginate beads in a bubble continuous reactor. High color removal (87–98%) was attained for both dyes operating at a residence time of 30 min, without operational problems and maintaining particle shapes throughout the oxidation process. Consequently, the stable performance of Fe alginate beads opens promising perspectives for fast and economical treatment of wastewater polluted by dyes or similar organic contaminants.

  12. Decolourisation of dyes under electro-Fenton process using Fe alginate gel beads

    Energy Technology Data Exchange (ETDEWEB)

    Rosales, E.; Iglesias, O.; Pazos, M. [Department of Chemical Engineering, University of Vigo, Isaac Newton Building, Campus As Lagoas, Marcosende 36310, Vigo (Spain); Sanroman, M.A., E-mail: sanroman@uvigo.es [Department of Chemical Engineering, University of Vigo, Isaac Newton Building, Campus As Lagoas, Marcosende 36310, Vigo (Spain)

    2012-04-30

    Highlights: Black-Right-Pointing-Pointer Catalytic activity of Fe alginate gel beads for the remediation of wastewater was tested. Black-Right-Pointing-Pointer New electro-Fenton process for the remediation of polluted wastewater. Black-Right-Pointing-Pointer Continuous dye treatment without operational problem with high removal. - Abstract: This study focuses on the application of electro-Fenton technique by use of catalytic activity of Fe alginate gel beads for the remediation of wastewater contaminated with synthetic dyes. The Fe alginate gel beads were evaluated for decolourisation of two typical dyes, Lissamine Green B and Azure B under electro-Fenton process. After characterization of Fe alginate gel beads, the pH effect on the process with Fe alginate beads and a comparative study of the electro-Fenton process with free Fe and Fe alginate bead was done. The results showed that the use of Fe alginate beads increases the efficiency of the process; moreover the developed particles show a physical integrity in a wide range of pH (2-8). Around 98-100% of dye decolourisation was obtained for both dyes by electro-Fenton process in successive batches. Therefore, the process was performed with Fe alginate beads in a bubble continuous reactor. High color removal (87-98%) was attained for both dyes operating at a residence time of 30 min, without operational problems and maintaining particle shapes throughout the oxidation process. Consequently, the stable performance of Fe alginate beads opens promising perspectives for fast and economical treatment of wastewater polluted by dyes or similar organic contaminants.

  13. Photocatalytic degradation and photo-Fenton oxidation of Congo red dye pollutants in water using natural chromite—response surface optimization

    Science.gov (United States)

    Shaban, Mohamed; Abukhadra, Mostafa R.; Ibrahim, Suzan S.; Shahien, Mohamed. G.

    2017-12-01

    Refined natural Fe-chromite was characterized by XRD, FT-IR, reflected polarized microscope, XRF and UV spectrophotometer. Photocatalytic degradation and photo-Fenton oxidation of Congo red dye by Fe-chromite was investigated using 1 mL H2O2. The degradation of dye was studied as a function of illumination time, chromite mass, initial dye concentration, and pH. Fe-chromite acts as binary oxide system from chromium oxide and ferrous oxide. Thus, it exhibits photocatalytic properties under UV illumination and photo-Fenton oxidation after addition of H2O2. The degradation in the presence of H2O2 reached the equilibrium stage after 8 h (59.4%) but in the absence of H2O2 continued to 12 h (54.6%). Photocatalytic degradation results fitted well with zero, first order and second order kinetic model but it represented by second order rather than by the other models. While the photo-Fenton oxidation show medium fitting with the second order kinetic model only. The values of kinetic rate constants for the photo-Fenton oxidation were greater than those for the photocatalytic degradation. Thus, degradation of Congo red dye using chromite as catalyst is more efficient by photo-Fenton oxidation. Based on the response surface analysis, the predicted optimal conditions for maximum removal of Congo red dye by photocatalytic degradation (100%) were 12 mg/l, 0.14 g, 3, and 11 h for dye concentration, chromite mass, pH, and illumination time, respectively. Moreover, the optimum condition for photo-Fenton oxidation of dye (100%) is 13.5 mg/l, 0.10 g, 4, and 10 h, respectively.

  14. Ferrous ions reused as catalysts in Fenton-like reactions for remediation of agro-food industrial wastewater.

    Science.gov (United States)

    Leifeld, Vanessa; Dos Santos, Tâmisa Pires Machado; Zelinski, Danielle Wisniewski; Igarashi-Mafra, Luciana

    2018-09-15

    Cassava is the most important tuberous root in tropical and subtropical regions of the world, being the third largest source of carbohydrates. The root processing is related to the production of starch, an important industrial input, which releases a highly toxic liquid wastewater due to its complex composition, which inhibits high performances of conventional effluent treatments. This study aims to evaluate Fenton-like and photo-Fenton-like reactions for treatment of cassava wastewater, reusing ferrous ions from the preliminary coagulation stage. Pre-treated cassava wastewater was submitted to oxidation in three variations of hydrogen peroxide concentrations, with more relevant analytical responses verified in color, turbidity, COD (Chemical Oxygen Demand), and acute toxicity in Artemia salina, besides the action of radicals during Fenton-like reactions. At higher peroxide concentrations, a decrease of 68% in turbidity and 70% in COD on the photo-Fenton-like system was observed, even at slow reaction rates (fastest rate constant k = 2 × 10 -4 min -1 ). Inclusion of UV increases the viability of the Fenton-like reactions by supplementing the reaction medium with hydroxyl radicals, verified by the tert-butanol tests. The oxidation process leads to high EC 50 values in 24 h of incubation in Fenton-like reactions and 48 h in photo-Fenton-like reactions. Final COD and turbidity suggests that the reuse of iron, which remains in the preliminary treatment step shows a great potential as a catalyst for Fenton-like advanced oxidation processes. Tertiary treatment can be less expensive and harmful to the environment, reducing production of residual sludge and metal content in the final effluent, which reduces polluting potential of the effluent regarding solid waste. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Fenton-driven regeneration of MTBE-spent granular activated carbon - Effects of particle size and Iron Amendment Procedures

    Science.gov (United States)

    Fenton-driven regeneration of spent granular activated carbon (GAC) is a technology being developed to regenerate organic contaminant-spent GAC. Here, the effect of GAC particle size (>2 mm to <0.35 mm) on Fenton-driven oxidation of methyl tert-butyl ether (MTBE)-spent GAC was ev...

  16. Fe(III/TiO2-Montmorillonite Photocatalyst in Photo-Fenton-Like Degradation of Methylene Blue

    Directory of Open Access Journals (Sweden)

    Is Fatimah

    2015-01-01

    Full Text Available A photodegradation process of methylene blue (MB in aqueous solution using Fe(III/TiO2-montmorillonite photocatalyst is presented. The photocatalyst material was prepared using Indonesian natural montmorillonite in TiO2 pillarization process followed by Fe(III ion exchange. Kinetic study on MB degradation was conducted and evaluated by three kinetic models: the pseudo-first- and second-order equations and the Elovich equation. From the results, it is concluded that the degradation under the photo-Fenton-like process utilizing Fe(III/TiO2-montmorillonite photocatalyst conformed to the Elovich kinetic model.

  17. Degradation of Procion Red H-E7B reactive dye by coupling a photo-Fenton system with a sequencing batch reactor

    International Nuclear Information System (INIS)

    Garcia-Montano, Julia; Torrades, Francesc; Garcia-Hortal, Jose A.; Domenech, Xavier; Peral, Jose

    2006-01-01

    A bench-scale study combining photo-Fenton reaction with an aerobic sequencing batch reactor (SBR) to degrade a commercial homo-bireactive dye (Procion Red H-E7B, 250 mg l -1 ) was investigated. The photo-Fenton process was applied as a pre-treatment, avoiding complete mineralisation, just to obtain a bio-compatible water able to be treated by means of the SBR in a second step. In this sense, different Fenton reagent concentrations were assessed by following dye solution biodegradability enhancement (BOD 5 /COD), as well as the toxicity (EC 50 ), DOC, colour (Abs 543.5 ) and H 2 O 2 evolution with photo-Fenton irradiation time. Obtained pre-treated solutions were biologically oxidized in a SBR containing non-acclimated activated sludge. Different hydraulic retention time (HRT) in the bioreactor were tested to attain the maximum organic load removal efficiency. Best results were obtained with 60 min of 10 mg l -1 Fe(II) and 125 mg l -1 H 2 O 2 photo-Fenton pre-treatment and 1 day HRT in SBR

  18. Hot Dry Rock Geothermal Energy Development Program. Annual report, fiscal year 1979

    Energy Technology Data Exchange (ETDEWEB)

    Cremer, G.M.; Duffield, R.B.; Smith, M.C.; Wilson, M.G. (comps.)

    1980-08-01

    The Fenton Hill Project is still the principal center for developing methods, equipment, and instrumentation for creating and utilizing HDR geothermal reservoirs. The search for a second site for a similar experimental system in a different geological environment has been intensified, as have the identification and characterization of other HDR areas that may prove suitable for either experimental or commercial development. The Phase I fracture system was enlarged during FY79. Drilling of the injection well of the Phase II system began at Fenton Hill in April 1979. Environmental monitoring of the Fenton Hill area continued through FY79. The environmental studies indicate that the hot dry rock operations have caused no significant environmental impact. Other supporting activities included rock physics, rock mechanics, fracture mapping, and instrumentation development. Two closely related activities - evaluation of the potential HDR energy resource of the US and the selection of a site for development of a second experimental heat-extraction system generally similar to that at Fenton Hill - have resulted in the collection of geology, hydrology, and heat-flow data on some level of field activity in 30 states. The resource-evaluation activity included reconnaissance field studies and a listing and preliminary characterization of US geothermal areas in which HDR energy extraction methods may be applicable. The selection of Site 2 has taken into account such legal, institutional, and economic factors as land ownership and use, proximity to possible users, permitting and licensing requirements and procedures, environmental issues, areal extent of the geothermal area, and visibility to and apparent interest by potential industrial developers.

  19. The Vitamin E Analog Gamma-Tocotrienol (GT3 and Statins Synergistically Up-Regulate Endothelial Thrombomodulin (TM

    Directory of Open Access Journals (Sweden)

    Rupak Pathak

    2016-11-01

    Full Text Available Statins; a class of routinely prescribed cholesterol-lowering drugs; inhibit 3-hydroxy-3-methylglutaryl-coenzymeA reductase (HMGCR and strongly induce endothelial thrombomodulin (TM; which is known to have anti-inflammatory; anti-coagulation; anti-oxidant; and radioprotective properties. However; high-dose toxicity limits the clinical use of statins. The vitamin E family member gamma-tocotrienol (GT3 also suppresses HMGCR activity and induces TM expression without causing significant adverse side effects; even at high concentrations. To investigate the synergistic effect of statins and GT3 on TM; a low dose of atorvastatin and GT3 was used to treat human primary endothelial cells. Protein-level TM expression was measured by flow cytometry. TM functional activity was determined by activated protein C (APC generation assay. Expression of Kruppel-like factor 2 (KLF2, one of the key transcription factors of TM, was measured by quantitative reverse transcription polymerase chain reaction (qRT-PCR. TM expression increased in a dose-dependent manner after both atorvastatin and GT3 treatment. A combined treatment of a low-dose of atorvastatin and GT3 synergistically up-regulated TM expression and functional activity. Finally; atorvastatin and GT3 synergistically increased KLF2 expression. These findings suggest that combined treatment of statins with GT3 may provide significant health benefits in treating a number of pathophysiological conditions; including inflammatory and cardiovascular diseases.

  20. Presentation summary: Gas Turbine - Modular Helium Reactor (GT-MHR)

    International Nuclear Information System (INIS)

    2001-01-01

    Numerous prototypes and demonstration plants have been constructed and operated beginning with the Dragon plant in the early 1960s. The MHTGR was the U.S. developed modular plant and underwent pre application review by NRC. The GT-MHR represents a further refinement on this concept with the steam cycle being replaced by a closed loop gas turbine (Brayton) cycle. Modular gas reactors and the GT-MHR represent a fundamental shift in reactor design and safety philosophy. The reactor system is contained in a 3 vessel, side-by-side arrangement. The reactor and a shutdown cooling system are in one vessel, and the gas turbine based power conversion system, including the generator, in a second parallel vessel. A more detailed look at the system shows the compact arrangement of gas turbine, compressors, recuperator, heat exchanges, and generator. Fueled blocks are stacked in three concentric rings with inert graphite blocks making up the inner and outer reflectors. Operating control rods are located outside the active core while startup control rods and channels for reserve shutdown pellets are located near the core center. Ceramic coated fuel is the key to the GT-MHR's safety and economics. A kernel of Uranium oxycarbide (or UO 2 ) is placed in a porous carbon buffer and then encapsulated in multiple layers of pyrolytic carbon and silicon carbide. These micro pressure vessels withstand internal pressures of up to 2,000 psi and temperatures of nearly 2,000 C providing extremely resilient containment of fission products under both normal operating and accident conditions. The fuel particles are blended in carbon pitch, forming fuel rods, and then loaded into holes within large graphite fuel elements. Fuel elements are stacked to form the core. Fuel particle testing in has repeatedly demonstrated the high temperature resilience of coated particle fuel to temperature approaching 2,000 C. As an conservative design goal, GT-MHR has been sized to keep maximum fuel temperatures

  1. LU60645GT and MA132843GT Catalogues of Lunar and Martian Impact Craters Developed Using a Crater Shape-based Interpolation Crater Detection Algorithm for Topography Data

    Science.gov (United States)

    Salamuniccar, Goran; Loncaric, Sven; Mazarico, Erwan Matias

    2012-01-01

    For Mars, 57,633 craters from the manually assembled catalogues and 72,668 additional craters identified using several crater detection algorithms (CDAs) have been merged into the MA130301GT catalogue. By contrast, for the Moon the most complete previous catalogue contains only 14,923 craters. Two recent missions provided higher-quality digital elevation maps (DEMs): SELENE (in 1/16° resolution) and Lunar Reconnaissance Orbiter (we used up to 1/512°). This was the main motivation for work on the new Crater Shape-based interpolation module, which improves previous CDA as follows: (1) it decreases the number of false-detections for the required number of true detections; (2) it improves detection capabilities for very small craters; and (3) it provides more accurate automated measurements of craters' properties. The results are: (1) LU60645GT, which is currently the most complete (up to D>=8 km) catalogue of Lunar craters; and (2) MA132843GT catalogue of Martian craters complete up to D>=2 km, which is the extension of the previous MA130301GT catalogue. As previously achieved for Mars, LU60645GT provides all properties that were provided by the previous Lunar catalogues, plus: (1) correlation between morphological descriptors from used catalogues; (2) correlation between manually assigned attributes and automated measurements; (3) average errors and their standard deviations for manually and automatically assigned attributes such as position coordinates, diameter, depth/diameter ratio, etc; and (4) a review of positional accuracy of used datasets. Additionally, surface dating could potentially be improved with the exhaustiveness of this new catalogue. The accompanying results are: (1) the possibility of comparing a large number of Lunar and Martian craters, of e.g. depth/diameter ratio and 2D profiles; (2) utilisation of a method for re-projection of datasets and catalogues, which is very useful for craters that are very close to poles; and (3) the extension of the

  2. Study of the degradation performance (TOC, BOD, and toxicity) of bisphenol A by the photo-Fenton process.

    Science.gov (United States)

    Pérez-Moya, M; Kaisto, T; Navarro, M; Del Valle, L J

    2017-03-01

    Degradation of bisphenol A (BPA, 0.5 L, 30 mg L -1 ) was studied by photo-Fenton treatment, while Fenton reagents were variables. The efficiency of the degradation process was evaluated by the reduction of total organic carbon (TOC), the biochemical oxygen demand (BOD), and toxicity. For toxicity analysis, bacterial methods were found infeasible, but the in vitro assay of VERO cells culture was successfully applied. Experiments according to a 2 2 design of experiments (DOE) with star points and three center points for statistical validity allowed selecting those process conditions (Fe(II) and H 2 O 2 load) that maximized the process performance. Photo-Fenton process effectively eliminated BPA and partly degraded its by-products (residual TOC TOC = 92 %) was attained. Toxicity was also detected to 50 % of cellular mortality even at long reaction times. However, 40.25 mg L -1 of H 2 O 2 decreased residual TOC to 70 % while cell mortality decreased down to 25 %. With more H 2 O 2 , the residual TOC decreased down to 15 % but cell mortality remained within the 20-25 % level. Photo-Fenton increased the biodegradability and reduced the toxicity of the studied sample.

  3. Enhanced heterogeneous photo-Fenton process modified by magnetite and EDDS: BPA degradation.

    Science.gov (United States)

    Huang, Wenyu; Luo, Mengqi; Wei, Chaoshuai; Wang, Yinghui; Hanna, Khalil; Mailhot, Gilles

    2017-04-01

    In this research, magnetite and ethylenediamine-N,N'-disuccinic acid (EDDS) are used in a heterogeneous photo-Fenton system in order to find a new way to remove organic contaminants from water. Influence of different parameters including magnetite dosage, EDDS concentration, H 2 O 2 concentration, and pH value were evaluated. The effect of different radical species including HO · and HO 2 · /O 2 ·- was investigated by addition of different scavengers into the system. The addition of EDDS improved the heterogeneous photo-Fenton degradation of bisphenol A (BPA) through the formation of photochemically efficient Fe-EDDS complex. This effect is dependent on the H 2 O 2 and EDDS concentrations and pH value. The high performance observed at pH 6.2 could be explained by the ability of O 2 ·- to generate Fe(II) from Fe(III) species reduction. GC-MS analysis suggested that the cleavage of the two benzene rings is the first degradation step followed by oxidation leading to the formation of the benzene derivatives. Then, the benzene ring was opened due to the attack of HO · radicals producing short-chain organic compounds of low molecular weight like glycerol and ethylene glycol. These findings regarding the capability of EDDS/magnetite system to promote heterogeneous photo-Fenton oxidation have important practical implications for water treatment technologies.

  4. Using single-chamber microbial fuel cells as renewable power sources of electro-Fenton reactors for organic pollutant treatment

    KAUST Repository

    Zhu, Xiuping

    2013-05-01

    Electro-Fenton reactions can be very effective for organic pollutant degradation, but they typically require non-sustainable electrical power to produce hydrogen peroxide. Two-chamber microbial fuel cells (MFCs) have been proposed for pollutant treatment using Fenton-based reactions, but these types of MFCs have low power densities and require expensive membranes. Here, more efficient dual reactor systems were developed using a single-chamber MFC as a low-voltage power source to simultaneously accomplish H2O2 generation and Fe2+ release for the Fenton reaction. In tests using phenol, 75±2% of the total organic carbon (TOC) was removed in the electro-Fenton reactor in one cycle (22h), and phenol was completely degraded to simple and readily biodegradable organic acids. Compared to previously developed systems based on two-chamber MFCs, the degradation efficiency of organic pollutants was substantially improved. These results demonstrate that this system is an energy-efficient and cost-effective approach for industrial wastewater treatment of certain pollutants. © 2013 Elsevier B.V.

  5. Evaluation of the mercaptobenzothiazole degradation by combined adsorption process and Fenton reaction using iron mining residue.

    Science.gov (United States)

    Martins, Adriana Lau da Silva; Teixeira, Luís Alberto César; da Fonseca, Fabiana Valéria; Yokoyama, Lídia

    2017-08-01

    The present study investigated the degradation of mercaptobenzothiazole (MBT), evaluating homogeneous and heterogeneous systems. An iron mineral residue from the desliming step of iron mining was used as a source in the Fenton-like reaction (advanced oxidation process). A granulometric analysis of the residue was performed and yielded fractions with high hematite (Fe 2 O 3 ) and low quartz content in sieves from 74 to below 44 mm. In this particle size range, the hematite content from 58.9% to 67.4% and the Brunauer-Emmett-Teller area from 0.1345 to 1.3137 m 2  g -1 were obtained. The zeta potential curves as a function of pH were obtained for the residue, the MBT solution and mixtures thereof. The adsorption of MBT in the residue and its degradation through the Fenton-like reaction were investigated. Adsorption tests and the Fenton-like reaction were carried out, where the MBT species and the residue are oppositely charged, yielding, respectively, 10% MBT adsorption on the surface of the residue and 100% MBT degradation by the Fenton-like reaction at pH 3, hydrogen peroxide concentration of 25 mg L -1 , residue concentration of 3 g L -1 , 200 rpm and 25°C, from a 100 mg L -1 MBT solution. MBT degradation was found to occur mainly by the heterogeneous Fenton-like process.

  6. Degradation of sodium dodecyl sulphate in water using solar driven Fenton-like advanced oxidation processes

    International Nuclear Information System (INIS)

    Bandala, Erick R.; Pelaez, Miguel A.; Salgado, Maria J.; Torres, Luis

    2008-01-01

    Synthetic wastewater samples containing a model surfactant were treated using two different Fenton-like advanced oxidation processes promoted by solar radiation; the photo-Fenton reaction and Co/PMS/UV processes. Comparison between the different experimental conditions was performed by means of the overall surfactant degradation achieved and by obtaining the initial rate in the first 15 min of reaction (IR 15 ). It was found that, for dark Fenton reaction, the maximum surfactant degradation achieved was 14% under low iron and oxidant concentration. Increasing Fenton reagents by one magnitude order, surfactant degradation achieved 63% in 60 min. The use of solar radiation improved the reaction rate by 17% under same conditions and an additional increase of 12.5% was obtained by adjusting initial pH to 2. IR 15 values for dark and irradiated Fenton reactions were 0.143 and 0.154 mmol/min, respectively, for similar reaction conditions and this value increased to 0.189 mmol/min when initial pH was adjusted. The use of the Co/PMS system allow us to determine an increase in the degradation rate, for low reaction conditions (1 mM of transition metal; 4 mM oxidant) similar to those used in dark Fenton reaction. Surfactant degradation increased from 3%, for Fenton reaction, to 44.5% in the case of Co/PMS. When solar irradiation was included in the experiments, under same reaction conditions described earlier, surfactant degradation up to 64% was achieved. By increasing Co/PMS reagent concentration by almost 9 times under irradiated conditions, almost complete (>99%) surfactant degradation was reached in 5 min. Comparing IR 15 values for Co/PMS and Co/PMS/UV, it allow us to observe that the use of solar radiation increased the degradation rate in one magnitude order when compared with dark experiments and further increase of reagent concentration increased reaction rate twice

  7. Application of Fenton process to remove organic matter and PCBs from waste (fuller's earth) contaminated with insulating oil.

    Science.gov (United States)

    da Silva, Milady Renata Apolinário; Rodrigues, Eduardo de Oliveira; Espanhol-Soares, Melina; Silva, Flavio Soares; Kondo, Márcia Matiko; Gimenes, Rossano

    2018-01-09

    Polychlorinated biphenyls (PCBs) are carcinogenic to humans and can be found in fuller's earth used for the treatment of used transformer oil. This work describes an optimization of the Fenton process for the removal of contaminants from fuller's earth. The effects of pH (2.5 and 4.0), [H 2 O 2 ] (1.47 and 2.07 mol L -1 ), and [Fe 2+ ] (1.7 and 40 mmol L -1 ) were studied. The Fenton process efficiency was monitored using the decreases in the chemical oxygen demand (COD) and the concentrations of oil and grease, total carbon (TC), PCBs, and H 2 O 2 . The fuller's earth contaminated with insulating oil presented 35% (w/w) of TC, 34% (w/w) of oil and grease, 297.0 g L -1 COD, and 64 mg of PCBs per kg. The material could therefore be considered a dangerous waste. After Fenton treatment, using a slurry mode, there was a removal of 55% of COD, 20% of oil and grease, and 20% of TC, achieved at pH 2.5 using 2.07 mol L -1 of H 2 O 2 and 40.0 mmol L -1 of Fe 2+ . No PCBs were detected in the samples after the Fenton treatment, even using smaller amounts of Fenton reagents (1.47 mol L -1 of H 2 O 2 , 1.7 mmol L -1 of Fe 2+ , pH 2.5). The results indicated that the treated fuller's earth was free from PCB residues and could be disposed of in a simple landfill, in accordance with Brazilian PCB regulations.

  8. A bionic system with Fenton reaction and bacteria as a model for bioprocessing lignocellulosic biomass.

    Science.gov (United States)

    Zhang, Kejing; Si, Mengying; Liu, Dan; Zhuo, Shengnan; Liu, Mingren; Liu, Hui; Yan, Xu; Shi, Yan

    2018-01-01

    The recalcitrance of lignocellulosic biomass offers a series of challenges for biochemical processing into biofuels and bio-products. For the first time, we address these challenges with a biomimetic system via a mild yet rapid Fenton reaction and lignocellulose-degrading bacterial strain Cupriavidus basilensis B-8 (here after B-8) to pretreat the rice straw (RS) by mimicking the natural fungal invasion process. Here, we also elaborated the mechanism through conducting a systematic study of physicochemical changes before and after pretreatment. After synergistic Fenton and B-8 pretreatment, the reducing sugar yield was increased by 15.6-56.6% over Fenton pretreatment alone and 2.7-5.2 times over untreated RS (98 mg g -1 ). Morphological analysis revealed that pretreatment changed the surface morphology of the RS, and the increase in roughness and hydrophilic sites enhanced lignocellulose bioavailability. Chemical components analyses showed that B-8 removed part of the lignin and hemicellulose which caused the cellulose content to increase. In addition, the important chemical modifications also occurred in lignin, 2D NMR analysis of the lignin in residues indicated that the Fenton pretreatment caused partial depolymerization of lignin mainly by cleaving the β- O -4 linkages and by demethoxylation to remove the syringyl (S) and guaiacyl (G) units. B-8 could depolymerize amount of the G units by cleaving the β-5 linkages that interconnect the lignin subunits. A biomimetic system with a biochemical Fenton reaction and lignocellulose-degrading bacteria was confirmed to be able for the pretreatment of RS to enhance enzymatic hydrolysis under mild conditions. The high digestibility was attributed to the destruction of the lignin structure, partial hydrolysis of the hemicellulose and partial surface oxidation of the cellulose. The mechanism of synergistic Fenton and B-8 pretreatment was also explored to understand the change in the RS and the bacterial effects on

  9. Life cycle assessment of an SOFC/GT process

    Energy Technology Data Exchange (ETDEWEB)

    Olausson, Pernilla

    1999-06-01

    For the last few years much effort has been put into the research on different kinds of fuel cells, since these are considered to be both an efficient and environment friendly way to convert energy. The fuel cell studied here is the solid oxide fuel cell (SOFC) that works at a high temperature (800-1000 C) and today achieves a stand-alone electric efficiency of approximately 50%. When integrating the SOFC in a gas turbine process (SOFC/GT process) an efficiency of 70-75% can be reached. The SOFC and the SOFC/GT process are considered to be environment friendly regarding the discharges during operation. Especially formation of nitrogen oxides (NO{sub x}) is low since the SOFC temperatures are low compared to NO{sub x} formation temperatures. To study the whole environmental impact of the SOFC/GT process a life cycle assessment (LCA) is carried out to find the `hot spots` in the process` life cycle. Since the SOFC/GT process is under development today the collected data are mainly from literature and articles based on laboratory results. When performing the LCA only the SOFC-module and the gas turbine are included. A collection of data of all processes included, extraction of minerals, processing of raw material, production of the components, operation of the SOFC/GT process and transports between all these processes. These data are then added up and weighted in impact categories to evaluate the total environmental impact of the SOFC/GT process. All these steps are performed according to the ISO 14040-series. The stand-alone most contributing phase during the life cycle of the SOFC/GT process was found to be the production of the SOFC. All processes during the production of the SOFC are carried out under laboratory circumstances, which require more energy and materials than if the processes were commercialised and optimised. For the SOFC/GT process to be competitive with other energy converting processes regarding the discharges of emissions to the air, the use of

  10. Sequential solar photo-fenton-biological system for the treatment of winery wastewaters.

    Science.gov (United States)

    Mosteo, R; Sarasa, J; Ormad, Maria P; Ovelleiro, J L

    2008-08-27

    In this study, winery wastewaters are considered for degradation using heterogeneous photo-Fenton as a preliminary step before biotreatment. The heterogeneous photo-Fenton process assisted by solar light is able to partially degrade the organic matter present in winery wastewaters. When an initial hydrogen peroxide concentration of 0.1 M is used over 24 h of treatment, a degradation yield of organic matter (measured as TOC) of around 50% is reached. The later treatment (activated sludge process) allows the elimination of 90% of the initial TOC present in pretreated winery wastewaters without producing nondesired side-effects, such as the bulking phenomenon, which is usually detected when this treatment is used alone. The final effluent contains a concentration of organic matter (measured as COD) of 128 mg O2/L. The coupled system comprising the heterogeneous photo-Fenton process and biological treatment based on activated sludge in simple stage is a real alternative for the treatment of winery wastewater.

  11. HTR-10GT AMBs displacement sensor design

    International Nuclear Information System (INIS)

    Shi Zhengang; Zha Meisheng; Zhao Lei; Sun Zhuo

    2005-01-01

    The 10 MW high temperature gas-cooled test module reactor (HTR-10GT) with the core made of spherical fuel elements was designed and constructed by the Institute of Nuclear and New Energy Technology of Tsinghua University in China. In the HTR-10GT, turbo-compressor and generator rotors are connected by a flexible coupling. The rotors, restricted by actual instruments and working environment, must be supported without any contact and lubrication. Active magnetic bearing (AMB), known as its advantages over the conventional bearings., such as contact-free, no-lubricating and active damping vibration, is the best way to suspend and stabilize the position of rotors of HTR-10GT. Each rotor is suspended by two radial and one axial AMBs. The radial AMB's radial gap is 0.15 mm considering the gap of 0.4 mm between the compressor stator and blades in order to protect the compressor. The control system controls the rotor position to meet the required gaps between rotor and stator through windings current. All the position information concerning radial and axial AMB is generated by sensors for measuring the displacement of the levitated body. Some typical sensors, i.e. eddy current displacement sensor, capacitive displacement sensor, can provide position information, but, quite often, unsatisfactory anti-jamming, which is a key issue for AMB systems near generator and other electric devices in HTR-10GT. Therefore, a kind of new type sensor is designed to measure the radial and axial displacements and the vibration of the rotors. This paper focuses on the design characteristics of the HTR-10GT AMBs displacement sensors and introduction of the related experiments to demonstrate its performance. (authors)

  12. Double-shell Fe2O3 hollow box-like structure for enhanced photo-Fenton degradation of malachite green dye

    Science.gov (United States)

    Jiang, De Bin; Liu, Xiaoying; Xu, Xuan; Zhang, Yu Xin

    2018-01-01

    In this work we demonstrate the synthesis of novel Fe2O3 nanosheets with double-shell hollow morphology by replica molding from diatomite framework. The nanostructures of Fe2O3 nanosheets were examined by focused-ion-beam scanning electron microscopy (FIB/SEM), X-ray diffraction spectroscopy (XRD), Brunauer-Emmett-Teller (BET) specific surface area measurements and Fourier transform infrared (FT-IR) spectroscopy. The results reveal that (1) Pure Fe2O3 nanosheets were successfully obtained; (2) The double-shell Fe2O3 hollow structure achieved via the NaOH etching silica method was observed; (3) Fe2O3 nanosheets possessed uniformly distributed porous nanosheets. Such structural features enlarged the specific surface area of Fe2O3 nanosheets and led to more catalytic active sites. In the heterogeneous photo-Fenton reaction, the double-shell Fe2O3 hollow morphology exhibited excellent catalytic capability for the degradation of malachite green (MG) at circumneutral pH condition. Under optimum condition, MG solution was almost completely decolorized in 60 min (99.9%). The Fe2O3 nanosheets also showed good stability and recyclability, demonstrating great potential as a promising photo-Fenton catalyst for the effective degradation of MG dye in wastewater.

  13. Degradation of Procion Red H-E7B reactive dye by coupling a photo-Fenton system with a sequencing batch reactor

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Montano, Julia [Departament de Quimica, Edifici Cn, Universitat Autonoma de Barcelona, E-08193 Bellaterra, Barcelona (Spain); Torrades, Francesc [Departament d' Enginyeria Quimica, ETSEI de Terrassa (UPC), C/Colom, 11, E-08222 Terrassa, Barcelona (Spain); Garcia-Hortal, Jose A. [Departament d' Enginyeria Textil i Paperera, ETSEI de Terrassa (UPC), C/Colom, 11, E-08222 Terrassa, Barcelona (Spain); Domenech, Xavier [Departament de Quimica, Edifici Cn, Universitat Autonoma de Barcelona, E-08193 Bellaterra, Barcelona (Spain); Peral, Jose [Departament de Quimica, Edifici Cn, Universitat Autonoma de Barcelona, E-08193 Bellaterra, Barcelona (Spain)]. E-mail: jose.peral@uab.es

    2006-06-30

    A bench-scale study combining photo-Fenton reaction with an aerobic sequencing batch reactor (SBR) to degrade a commercial homo-bireactive dye (Procion Red H-E7B, 250 mg l{sup -1}) was investigated. The photo-Fenton process was applied as a pre-treatment, avoiding complete mineralisation, just to obtain a bio-compatible water able to be treated by means of the SBR in a second step. In this sense, different Fenton reagent concentrations were assessed by following dye solution biodegradability enhancement (BOD{sub 5}/COD), as well as the toxicity (EC{sub 50}), DOC, colour (Abs{sub 543.5}) and H{sub 2}O{sub 2} evolution with photo-Fenton irradiation time. Obtained pre-treated solutions were biologically oxidized in a SBR containing non-acclimated activated sludge. Different hydraulic retention time (HRT) in the bioreactor were tested to attain the maximum organic load removal efficiency. Best results were obtained with 60 min of 10 mg l{sup -1} Fe(II) and 125 mg l{sup -1} H{sub 2}O{sub 2} photo-Fenton pre-treatment and 1 day HRT in SBR.

  14. Particle Size Effects on Fenton Regeneration of MTBE-spent Activated Carbon

    Science.gov (United States)

    Fenton-driven regeneration of spent granular activated carbon (GAC) is a developing technology that may reduce water treatment costs. In this study, the effect of GAC particle size on Fenton-driven oxidation of methyl tert-butyl ether (MTBE)-spent GAC was evaluated. The GAC was...

  15. Synergistic operation of photocatalytic degradation and Fenton process by magnetic Fe3O4 loaded TiO2

    Science.gov (United States)

    Sun, Qiong; Hong, Yong; Liu, Qiuhong; Dong, Lifeng

    2018-02-01

    The magnetic Fe3O4 loaded anatase TiO2 photocatalysts with different mass ratios were successfully synthesized by a one-step convenient calcining method. The morphology and structure analysis revealed that Fe3O4 was formed in TiO2 with very fine-grained particles. After a small amount of Fe3O4 loaded onto TiO2, the photocatalytic property enhanced obviously for the degradation of organic dye. Furthermore, the photo-Fenton-like catalysis of the iron-containing samples could also be induced after the addition of hydrogen peroxide. The apparent kinetic constant of the reaction that catalyzed by Fe-TiO2 was about 5.3 and 8.3 times of that catalyzed by TiO2 or Fe3O4 only, respectively, proving an effective synergistic contribution of the photocatalysis and Fenton reaction in the composite. Compared with Fe3O4 or free Fe3+ ions, only 13% of iron in TiO2 dissolved into acidic solution (25% for Fe3O4 and 100% for Fe3+) after the reaction, which confirmed the iron had been well immobilized onto TiO2. In addition, the extremely stable photocatalytic activity in cycling experiments proved the immobilized iron had been tightly attached onto TiO2, indicating the great potential of the catalyst for practical applications.

  16. Fe1-xZnxS ternary solid solution as an efficient Fenton-like catalyst for ultrafast degradation of phenol.

    Science.gov (United States)

    Gao, Jing; Liu, Yutang; Xia, Xinnian; Wang, Longlu; Dong, Wanyue

    2018-07-05

    Heterogeneous Fenton-like system has been proved to be an promising alternative to Fenton system due to its easy separation. However, it's a challenge to design heterogeneous Fenton-like catalysts with high activity and great durability. Here, ternary solid solution Fe 1-x Zn x S were prepared via hydrothermal synthesis as heterogeneous Fenton-like catalysts. The Fe 0.7 Zn 0.3 S sample exhibited state of the art activity for yielding OH by H 2 O 2 decomposition, and the ultrafast degradation of phenol was achieved in 4 min at initial acidic condition under room temperature. The phenol degradation rate constant of Fe 0.7 Zn 0.3 S was 99 and 70 times of ZnS and FeS, respectively. Further, we show that the unique structural configuration of iron atoms, the formation of FeS 2 -pyrite with (200) plane, are responsible for the excellent activity. The intermediate products were identified by LC-MS and a possible pathway was accordingly proposed to elucidate the mechanism of phenol degradation by OH. Overall, this work provides an idea for the rational design of the relevant heterogeneous Fenton-like catalysts. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Enhanced Fenton-like removal of nitrobenzene via internal microelectrolysis in nano zerovalent iron/activated carbon composite.

    Science.gov (United States)

    Hu, Sihai; Wu, Yaoguo; Yao, Hairui; Lu, Cong; Zhang, Chengjun

    2016-01-01

    The efficiency of Fenton-like catalysis using nano zerovalent iron (nZVI) is limited by nZVI aggregation and activity loss due to inactive ferric oxide forming on the nZVI surface, which hinders electron transfer. A novel iron-carbon composite catalyst consisting of nZVI and granular activated carbon (GAC), which can undergo internal iron-carbon microelectrolysis spontaneously, was successfully fabricated by the adsorption-reduction method. The catalyst efficiency was evaluated in nitrobenzene (NB) removal via the Fenton-like process (H2O2-nZVI/GAC). The results showed that nZVI/GAC composite was good for dispersing nZVI on the surface of GAC, which permitted much better removal efficiency (93.0%) than nZVI (31.0%) or GAC (20.0%) alone. Moreover, iron leaching decreased from 1.28 to 0.58 mg/L after reaction of 240 min and the oxidation kinetic of the Fenton-like reaction can be described well by the second-order reaction kinetic model (R2=0.988). The composite catalyst showed sustainable catalytic ability and GAC performed as a medium for electron transfer in internal iron-carbon microelectrolysis to promote Fe2+ regeneration and Fe3+/Fe2+ cycles. Therefore, this study represents an important method to design a low cost and high efficiency Fenton-like catalyst in practical application.

  18. Degradation of phthalate in aqueous solution by advanced oxidation process, photo-fenton

    International Nuclear Information System (INIS)

    Trabelsi, S.; Bellakhal, N.; Oturan, N.; Oturan, M.A.

    2009-01-01

    A photochemical method for degradation of persistent organic pollutants present in liquid effluents from the plastic industry and in the leaching described. This method, called P hoto-Fenton i nvolves the generation of radicals hydroxyl coupling between the Fenton reaction and photochemistry, OH radicals. Thus formed react with very high speeds, organic substances pollutants leading to their oxidation to total mineralization. In this study, we applied the process photo-Fenton treatment Plasticizers, Phthalates. For this, optimization of experimental parameters (namely the relationship between the concentrations of hydrogen peroxide and iron concentration catalyst) was performed. Under optimal conditions and determined the kinetics mineralization of phthalic anhydride by OH was studied. The overall results confirm the effectiveness of photo-Fenton process for the decontamination of liquid effluents responsible for persistent organic pollutants (Pop's).

  19. Fenton's syndrome

    International Nuclear Information System (INIS)

    Rimondi, E.; Albasini, V.

    1989-01-01

    The authors report two recent cases of Fenton's syndrome, a very rare carpal fracture-dislocation. After some anatomophysiopathological considerations and a review of the literature, a wider nosographic frame is proposed in which the entity of the dislocation of the head of capitate bone is not essential. According to both the literature and personal findings, the authors remark that this syndrome is always found in the presence of two morphological variants of the distal radioulnar joint. Finally, the authors stress the importance of a corect diagnosis of this lesion to avoid unnecessary attempts of reduction

  20. Fenton Coagulation/Oxidation Using Fe2+ and Fe3+ Íons and Peracetic Acid for the Treatment of Wastewater

    Directory of Open Access Journals (Sweden)

    Grasiele Soares Cavallini

    2015-09-01

    Full Text Available The Fenton coagulation/oxidation process is divided into two steps: coagulation, in alkaline pH and oxidation, in acid pH. This configuration provides a reduction in oxidant concentration, due to the pretreatment conducted in the coagulation step. This study proposes the substitution of hydrogen peroxide (HP by peracetic acid (PAA in a Fenton coagulation process to treat sanitary sewage and provide its disinfection. The new combination is proposed in a single step and presented good results in removing turbidity (98.5%, apparent color (95.4%, phosphorus (100% and COD (58.2% even at the effluent natural pH, besides demonstrating higher reduction in E. coli when compared with the process that employs hydrogen peroxide. The formation of Fe3+ ions was shown to be responsible for the removal of the particulate material. DOI: http://dx.doi.org/10.17807/orbital.v7i3.626 

  1. Disintegration and dissolution of spent radioactive cationic exchange resins using Fenton-like oxidation process

    International Nuclear Information System (INIS)

    Wan, Zhong; Xu, Lejin; Wang, Jianlong

    2015-01-01

    Highlights: • The spent radioactive resins could be oxidized by Fenton-like process. • The influencing factors on resin oxidation were evaluated. • Chemical oxygen demand (COD) reduction rate was more than 99%. • SEM and Raman spectrum were used to analyze the resins morphological change. - Abstract: The treatment and disposal of the spent radioactive resins is essential for the sustainable development of the nuclear industry. In this paper, the disintegration and dissolution of spent cationic resins were studied by Fenton-like process. The influencing factors on resin dissolution, such as pH, temperature, type and concentration of catalysts were evaluated. The results showed that the spent resins could be effectively dissolved at pH < 1, [Fe 2+ ] = 0.2 M and T = 97 ± 2 °C. Chemical oxygen demand (COD) reduction rate was more than 99%. The scanning electron microscopy and the Raman spectrum were used to observe the morphological changes of the spent resins during the dissolution process. Fenton-like oxidation is an efficient method for the volume reduction and stabilization of the spent resins before further immobilization

  2. Disintegration and dissolution of spent radioactive cationic exchange resins using Fenton-like oxidation process

    Energy Technology Data Exchange (ETDEWEB)

    Wan, Zhong; Xu, Lejin [Collaborative Innovation Center for Advanced Nuclear Energy Technology, INET, Tsinghua University, Beijing 100084 (China); Wang, Jianlong, E-mail: wangjl@tsinghua.edu.cn [Collaborative Innovation Center for Advanced Nuclear Energy Technology, INET, Tsinghua University, Beijing 100084 (China); Beijing Key Laboratory of Radioactive Wastes Treatment, Tsinghua University, Beijing 100084 (China)

    2015-09-15

    Highlights: • The spent radioactive resins could be oxidized by Fenton-like process. • The influencing factors on resin oxidation were evaluated. • Chemical oxygen demand (COD) reduction rate was more than 99%. • SEM and Raman spectrum were used to analyze the resins morphological change. - Abstract: The treatment and disposal of the spent radioactive resins is essential for the sustainable development of the nuclear industry. In this paper, the disintegration and dissolution of spent cationic resins were studied by Fenton-like process. The influencing factors on resin dissolution, such as pH, temperature, type and concentration of catalysts were evaluated. The results showed that the spent resins could be effectively dissolved at pH < 1, [Fe{sup 2+}] = 0.2 M and T = 97 ± 2 °C. Chemical oxygen demand (COD) reduction rate was more than 99%. The scanning electron microscopy and the Raman spectrum were used to observe the morphological changes of the spent resins during the dissolution process. Fenton-like oxidation is an efficient method for the volume reduction and stabilization of the spent resins before further immobilization.

  3. Bio-Electron-Fenton (BEF) process driven by microbial fuel cells for triphenyltin chloride (TPTC) degradation

    International Nuclear Information System (INIS)

    Yong, Xiao-Yu; Gu, Dong-Yan; Wu, Yuan-Dong; Yan, Zhi-Ying; Zhou, Jun; Wu, Xia-Yuan; Wei, Ping; Jia, Hong-Hua; Zheng, Tao; Yong, Yang-Chun

    2017-01-01

    Graphical abstract: Schematic diagram of the Bio-Electron-Fenton (BEF) process for TPTC degradation. - Highlights: • A Bio-Electro-Fenton process was performed for TPTC degradation. • TPTC removal efficiency achieved 78.32 ± 2.07% within 100 h. • The TPTC degradation rate (0.775 ± 0.021 μmol L"−"1 h"−"1) was much higher than previous reports. - Abstract: The intensive use of triphenyltin chloride (TPTC) has caused serious environmental pollution. In this study, an effective method for TPTC degradation was proposed based on the Bio-Electron-Fenton process in microbial fuel cells (MFCs). The maximum voltage of the MFC with graphite felt as electrode was 278.47% higher than that of carbon cloth. The electricity generated by MFC can be used for in situ generation of H_2O_2 to a maximum of 135.96 μmol L"−"1 at the Fe@Fe_2O_3_(_*_)/graphite felt composite cathode, which further reacted with leached Fe"2"+ to produce hydroxyl radicals. While 100 μmol L"−"1 TPTC was added to the cathodic chamber, the degradation efficiency of TPTC reached 78.32 ± 2.07%, with a rate of 0.775 ± 0.021 μmol L"−"1 h"−"1. This Bio-Electron-Fenton driving TPTC degradation might involve in Sn−C bonds breaking and the main process is probably a stepwise dephenylation until the formation of inorganic tin and CO_2. This study provides an energy saving and efficient approach for TPTC degradation.

  4. Preliminary safety evaluation of the Gas Turbine-Modular Helium Reactor (GT-MHR)

    International Nuclear Information System (INIS)

    Dunn, T.D.; Lommers, L.J.; Tangirala, V.E.

    1994-04-01

    A qualitative comparison between the safety characteristics of the Gas Turbine-Modular Helium Reactor (GT-MHR) and those of the steam cycle shows that the two designs achieve equivalent levels of overall safety performance. This comparison is obtained by applying the scaling laws to detailed steam-cycle computations as well as the conclusions obtained from preliminary GT-MHR model simulations. The gas turbine design is predicted to be superior for some event categories, while the steam cycle design is better for others. From a safety perspective, the GT-MHR has a modest advantage for pressurized conduction cooldown events. Recent computational simulations of 102 column, 550 MW(t) GT-MHR during a depressurized conduction cooldown show that peak fuel temperatures are within the limits. The GT-MHR has a significantly lower risk due to water ingress events under operating conditions. Two additional scenarios, namely loss of load event and turbine deblading event that are specific to the GT-MHR design are discussed. Preliminary evaluation of the GT-MHR's safety characteristics indicate that the GT-MHR can be expected to satisfy or exceed its safety requirements

  5. Optimization of radiolytic degradation of sulfadiazine by combining Fenton and gamma irradiation processes

    International Nuclear Information System (INIS)

    Rivas-Ortiz, Iram Barbaro; Cruz-Gonzalez, German; Manduca-Artiles, Michel; Jauregui-Haza, U.J.

    2017-01-01

    Gamma radiation (GR) is a promising technique, among known advanced oxidation processes, degrading water contaminants. Nevertheless, few authors report the degradation of sulfonamides by GR, and limited information exists concerning the use of GR in the case of sulfadiazine (SDZ). The objectives of this work are (1) evaluating GR as an alternative method for treating wastewater contaminated with SDZ and examinating the intensification of GR with oxidants (H 2 O 2 or Fenton reagent). GR was performed with a high-activity 60 Co source. The gamma radiation/Fenton process gave the best result, leading to total SDZ removal and high (74.13%) pollutant mineralization. (author)

  6. Removal of Refractory Organics from Biologically Treated Landfill Leachate by Microwave Discharge Electrodeless Lamp Assisted Fenton Process

    Directory of Open Access Journals (Sweden)

    Jiuyi Li

    2015-01-01

    Full Text Available Biologically treated leachate usually contains considerable amount of refractory organics and trace concentrations of xenobiotic pollutants. Removal of refractory organics from biologically treated landfill leachate by a novel microwave discharge electrodeless lamp (MDEL assisted Fenton process was investigated in the present study in comparison to conventional Fenton and ultraviolet Fenton processes. Conventional Fenton and ultraviolet Fenton processes could substantially remove up to 70% of the refractory organics in a membrane bioreactor treated leachate. MDEL assisted Fenton process achieved excellent removal performance of the refractory components, and the effluent chemical oxygen demand concentration was lower than 100 mg L−1. Most organic matters were transformed into smaller compounds with molecular weights less than 1000 Da. Ten different polycyclic aromatic hydrocarbons were detected in the biologically treated leachate, most of which were effectively removed by MDEL-Fenton treatment. MDEL-Fenton process provides powerful capability in degradation of refractory and xenobiotic organic pollutants in landfill leachate and could be adopted as a single-stage polishing process for biologically treated landfill leachate to meet the stringent discharge limit.

  7. Investigation of the impacts of ethyl lactate based Fenton treatment on soil quality for polycyclic aromatic hydrocarbons (PAHs)-contaminated soils.

    Science.gov (United States)

    Gan, Suyin; Yap, Chiew Lin; Ng, Hoon Kiat; Venny

    2013-11-15

    This study aims to investigate the impacts of ethyl lactate (EL) based Fenton treatment on soil quality for polycyclic aromatic hydrocarbons (PAHs)-contaminated soils. Accumulation of oxygenated-polycyclic aromatic hydrocarbons (oxy-PAHs) was observed, but quantitative measurement on the most abundant compound 9,10-anthraquinone (ATQ) showed lower accumulation of the compound than that reported for ethanol (ET) based Fenton treatment. In general, as compared to conventional water (CW) based Fenton treatment, the EL based Fenton treatment exerted either a lower or higher negative impact on soil physicochemical properties depending on the property type and shared the main disadvantage of reduced soil pH. For revegetation, EL based Fenton treatment was most appropriately adopted for soil with native pH >/~ 6.2 in order to obtain a final soil pH >/~ 4.9 subject to the soil buffering capacity. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Optimization of Acid Orange 7 Degradation in Heterogeneous Fenton-like Reaction Using Fe3-xCoxO4 Catalyst

    Science.gov (United States)

    Ibrahim, M. Z.; Alrozi, R.; Zubir, N. A.; Bashah, N. A.; Ali, S. A. Md; Ibrahim, N.

    2018-05-01

    The oxidation process such as heterogeneous Fenton and/or Fenton-like reactions is considered as an effective and efficient method for treatment of dye degradation. In this study, the degradation of Acid Orange 7 (AO7) was investigated by using Fe3-xCoxO4 as a heterogeneous Fenton-like catalyst. Response surface methodology (RSM) was used to optimize the operational parameters condition and the interaction of two or more parameters. The parameter studies were catalyst dosage (X1 ), pH (X2 ) and H2O2 concentration (X3 ) towards AO7 degradation. Based on analysis of variance (ANOVA), the derived quadratic polynomial model was significant whereby the predicted values matched the experimental values with regression coefficient of R2 = 0.9399. The optimum condition for AO7 degradation was obtained at catalyst dosage of 0.84 g/L, pH of 3 and H2O2 concentration of 46.70 mM which resulted in 86.30% removal of AO7 dye. These findings present new insights into the influence of operational parameters in the heterogeneous Fenton-like oxidation of AO7 using Fe3-xCoxO4 catalyst.

  9. Removal of organic pollutants in tannery wastewater from wet-blue fur processing by integrated Anoxic/Oxic (A/O) and Fenton: Process optimization

    DEFF Research Database (Denmark)

    Wang, Yong; Li, Weiguang; Angelidaki, Irini

    2014-01-01

    Treatment of tannery wastewater has been a challenge in remediation of aquatic environment in developing countries. Removal of organic pollutants in tannery wastewater from wet-blue fur processing was studied using integrated processes of Anoxic/Oxic and Fenton. Analysis of COD composition based...... 80%. In the subsequent Fenton oxidation, effects of initial pH and H2O2 dose on COD removal were investigated, and response surface methodology was adopted to obtain the optimal conditions as initial pH of 4.0, H2O2 dose of 14.0mM, H2O2:Fe2+ molar ratio of 10.6, and reaction time of 3h to achieve...... the highest COD removal of 55.87%. GC-MS analysis was carried out to observe the change of organic composition during Fenton oxidation, and most of the residual organic pollutants resistant to Fenton treatment belonged to organosilanes and saturated alkanes. This study will provide useful information...

  10. Treatment of Effluent from a Factory of Paints Using Solar Photo-Fenton Process

    Directory of Open Access Journals (Sweden)

    Alam Gustavo Trovó

    2013-01-01

    Full Text Available We evaluated the use of Fenton reactions induced by solar radiation in the treatment of effluent from a factory of paints for buildings, after prior removal of the suspended solids. The increase of H2O2 concentration from 100 to 2500 mg L−1 for a [Fe2+] = 105 mg L−1 contributed to the reduction of DOC, COD, and toxicity. Our best results were achieved using 1600 mg L−1 H2O2, with 90% of DOC and COD removal and a complete removal of the toxicity with respect to Artemia salina. Additionally, through increasing Fe2+ concentration from 15 to 45 mg L−1, the DOC removal rate increased 11 times, remaining almost constant in the range above 45 until 105 mg L−1. Under our best experimental conditions, 80% of DOC removal was achieved after an accumulated dose of 130 kJ m−2 of UVA radiation (82±17 min of solar irradiation under an average UVA irradiance of 34.1±7.3 W m−2, while 40% of DOC removal was reached after 150 min under only thermal Fenton reactions. The results suggest the effectiveness of implementation of solar photo-Fenton process in the decontamination and detoxification of effluents from factories of paints for buildings.

  11. Investigation the Efficiency of Combined Coagulation and Advanced Oxidation by Fenton Process in the Removal of Clarithromycin Antibiotic COD

    Directory of Open Access Journals (Sweden)

    Ahmad Reza Yazdanbakhsh

    2012-07-01

    Full Text Available Antibiotics are considered among the major pollutants in water environments. In this study, removal of Claritromycine antibiotic has been studied from synthetic wastewater by combined coagulation and advanced oxidation processes. This study, was done in laboratory scale .  Samples of synthetic wastewater  were prepared from Claritromycin antibiotic. Concentration of samples were 200 mg/l. COD index was selected as a parameter evaluated in this study. In the first stage, coagulation process was done on synthetic wastewater and the proper condition was achieved (proper coagulant, optimum pH, dosage of coagulant. After that, Fenton oxidation process was done, on the effluent of coagulation process. In Fenton process the influence of pH, Fe2+ and hydrogen peroxide were studied on the removal efficiency of Claritromycin antibiotic and the optimum values for each parameter were determined. According to the results of this study, Poly Aluminum Chloride (PAC  is the proper coagulant. With pH equal to 7 and 100 mg/l PAC, 84.37% removal of Claritromycine was achieved.  For fenton process, optimum parameters for the removal of Claritromycin were determined. The optimum condition for fenton process were, pH= 7, Fe2+ equal to 0.45 mmol/ l , hydrogen proxide equal to 0. 16 mmol/l, ratio of H2O2/Fe2+ equal to 0.4 and detention time of 1hour .With Applying of optimum conditions for combined coagulation and Fenton processes, 96.3% removal of Claritromycin was obtained.

  12. Mineralization of phthalic acid by solar photoelectro-Fenton with a stirred boron-doped diamond/air-diffusion tank reactor: Influence of Fe3+ and Cu2+ catalysts and identification of oxidation products

    International Nuclear Information System (INIS)

    Garcia-Segura, Sergi; Salazar, Ricardo; Brillas, Enric

    2013-01-01

    Highlights: • Almost total mineralization of phthalic acid by solar photoelectro-Fenton with Fe 3+ , Cu 2+ and Fe 3+ –Cu 2+ mixtures. • Hydroxyl radical generation from photo-Fenton reaction under solar radiation. • Enhancement of the mineralization rate using Fe 3+ and small amounts of Cu 2+ . • Detection of eleven aromatic intermediates and six short-linear carboxylic acids. • Oxidation of Cu(II)-carboxylate complexes with ·OH and photolysis of Fe(III)-carboxylate species. -- Abstract: Here, the substrate decay and mineralization rate for 100 cm 3 of a 2.0 mM phthalic acid solution in 0.10 M Na 2 SO 4 of pH 3.0 have been studied by electro-Fenton (EF) and solar photoelectro-Fenton (SPEF). The electrochemical cell was a stirred tank reactor containing a 3 cm 2 boron-doped diamond (BDD) anode and a 3 cm 2 air-diffusion cathode that generates H 2 O 2 . Cu 2+ and/or Fe 3+ were added as catalysts with total concentration of 0.50 mM and a constant current density of 33.3 mA cm −2 was applied. In EF with Cu 2+ or Fe 3+ alone and SPEF with only Cu 2+ , phthalic acid decayed slowly and poor mineralization was reached because the main oxidant was ·OH produced at the BDD surface from water oxidation. In contrast, the substrate destruction was largely enhanced using SPEF with 0.50 mM Fe 3+ since a high quantity of oxidant ·OH was produced in the bulk induced by photo-Fenton reaction. This treatment led to an almost total mineralization by the photolysis of generated Fe(III)-carboxylate complexes. In all cases, the decay of phthalic acid obeyed a pseudo-first-order reaction. The combination of Cu 2+ and Fe 3+ as catalysts accelerated the mineralization process in SPEF because Cu(II)-carboxylate complexes were also removed with ·OH formed from photo-Fenton reaction. The best SPEF process was found for 0.125 mM Cu 2+ + 0.375 mM Fe 3+ , giving rise to 99% mineralization with 40% current efficiency and 0.294 kWh g −1 TOC energy consumption. Eleven aromatics

  13. Heterocatalytic Fenton oxidation process for the treatment of tannery effluent: kinetic and thermodynamic studies.

    Science.gov (United States)

    Karthikeyan, S; Ezhil Priya, M; Boopathy, R; Velan, M; Mandal, A B; Sekaran, G

    2012-06-01

    BACKGROUND, AIM, SCOPE: Treatment of wastewater has become significant with the declining water resources. The presence of recalcitrant organics is the major issue in meeting the pollution control board norms in India. The theme of the present investigation was on partial or complete removal of pollutants or their transformation into less toxic and more biodegradable products by heterogeneous Fenton oxidation process using mesoporous activated carbon (MAC) as the catalyst. Ferrous sulfate (FeSO(4)·7H(2)O), sulfuric acid (36 N, specific gravity 1.81, 98% purity), hydrogen peroxide (50% v/v) and all other chemicals used in this study were of analytical grade (Merck). Two reactors, each of height 50 cm and diameter 6 cm, were fabricated with PVC while one reactor was packed with MAC of mass 150 g and other without MAC served as control. The oxidation process was presented with kinetic and thermodynamic constants for the removal of COD, BOD, and TOC from the wastewater. The activation energy (Ea) for homogeneous and heterogeneous Fenton oxidation processes were 44.79 and 25.89 kJ/mol, respectively. The thermodynamic parameters ΔG, ΔH, and ΔS were calculated for the oxidation processes using Van't Hoff equation. Furthermore, the degradation of organics was confirmed through FTIR and UV-visible spectroscopy, and cyclic voltammetry. The heterocatalytic Fenton oxidation process efficiently increased the biodegradability index (BOD/COD) of the tannery effluent. The optimized conditions for the heterocatalytic Fenton oxidation of organics in tannery effluent were pH 3.5, reaction time-4 h, and H(2)O(2)/FeSO(4)·7H(2)O in the molar ratio of 2:1.

  14. Estudo da degradação do metil parabeno utilizando processos Fenton, foto-Fenton e eletro-Fenton

    OpenAIRE

    Carlos Dante Gamarra Güere

    2014-01-01

    Os disruptores endócrinos são frequentemente relatados na literatura como contaminantes de ambientes aquáticos. Por isso, os processos oxidativos avançados (POAs) têm sido estudados como alternativa para o tratamento em meio aquoso. Os POAs consistem na oxidação de compostos orgânicos por radicais hidroxilas com alto poder oxidante. Diante desses aspectos, o presente trabalho tem como principal objetivo o estudo da degradação do metil parabeno (MeP) por processos Fenton, utilizando planejame...

  15. Parks of Chapel Hill

    Data.gov (United States)

    Town of Chapel Hill, North Carolina — Hours, location, and amenity information for Chapel Hill parks as shown on the Town of Chapel Hill's website. Includes a map with points for each park location.

  16. Iron Amendment and Fenton Oxidation of MTBE-Spent Granular Activated Carbon

    Science.gov (United States)

    Fenton-driven regeneration of Methyl tert-butyl ether (MTBE)-spent granular activated carbon (GAC) involves Fe amendment to the GAC to catalyze H2O2 reactions and to enhance the rate of MTBE oxidation and GAC regeneration. Four forms of iron (ferric sulfate, ferric chloride, fer...

  17. Soil washing in combination with homogeneous Fenton-like oxidation for the removal of 2,4,4'-trichlorodiphenyl from soil contaminated with capacitor oil.

    Science.gov (United States)

    Ma, Xiao-Hong; Zhao, Ling; Lin, Zhi-Rong; Dong, Yuan-Hua

    2016-04-01

    Detoxification by chemical oxidation of polychlorinated biphenyls (PCBs) in contaminated soils is very difficult and inefficient because PCBs typically associate with the solid phase or exist as non-aqueous-phase liquids due to their low solubility and slow desorption rates, and thus, they are difficult to remove from soils by using traditional, water-based elution techniques. Surfactant can enhance washing efficiency of PCBs from contaminated soils. This study used Brij 58, Brij 30, Tween 80, and 2-hydroxypropyl-β-cyclodextrin (HPCD) to solubilize 2,4,4'-trichlorodiphenyl (PCB28) from soil contaminated with capacitor oil into solution. The feasibility of PCB28 oxidation in soil washing wastewater through a Fe(3+)-catalyzed Fenton-like reaction was subsequently examined. Washing with 10 g L(-1) Brij 58 solution showed the highest extraction efficiency (up to 61.5 %) compared with that of the three other surfactants. The total concentration of PCB28 in contaminated soil at 25 °C after 48-h extraction was 286 mg L(-1). In contrast to conditions in which no washing agent was added, addition of the four washing agents decreased the efficiency of PCB28 degradation by the Fenton-like reaction, with the decrease due to addition of 10 g L(-1) Brij 58 solution being the smallest. The optimal concentration of H2O2 for preventing its useless decomposition was found to be 50 mM. The efficiency of PCB28 removal was lower when the initial concentration of PCB28 treated in the Fenton-like reaction was higher. The degradation efficiencies of PCB28 at initial concentrations of 0.1, 10, and 176 mg L(-1) in 10 g L(-1) Brij 58 solution at 25 °C and pH 3.0 and 9 h of reaction using 50 mM H2O2 were 64.1, 42.0, and 34.6 %, respectively. This result indicates that soil washing combined with Fenton-like oxidation may be a practical approach for the remediation of PCB-contaminated soil.

  18. Influence of Fenton's reagent treatment on electrochemical properties of graphite felt for all vanadium redox flow battery

    International Nuclear Information System (INIS)

    Gao, Chao; Wang, NanFang; Peng, Sui; Liu, SuQin; Lei, Ying; Liang, XinXing; Zeng, ShanShan; Zi, HuiFang

    2013-01-01

    Highlights: ► Highly hydroxyl-functionalized graphite felt has been obtained through Fenton's reagent treatment. ► Fenton's reagent treatment involves only one step, works under ambient conditions and will never produce any toxic gas. ► The treated graphite felt exhibits superior electrochemical performance in comparison to the untreated one. -- Abstract: An environmental, economic and highly effective method for carbon fiber hydroxylated-functionalization based on Fenton's reagent treatment is used to improve the electrochemical activity of graphite felt (GF) as the positive electrode in all vanadium redox flow battery (VRFB). The effect of H 2 O 2 content in Fenton's reagent on the structure and electrochemical properties of GF is investigated. The scanning electron microscope (SEM) indicates that the surface of the treated GF is etched increasingly with the content of H 2 O 2 . The Fourier transformation infrared (FTIR) spectroscopy shows that the peak intensity of hydroxyl groups on the treated felt is increased with the H 2 O 2 concentration, which is further verified by X-ray photoelectron spectroscopy (XPS). Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) show that the treated sample exhibits a higher electrochemical activity. A VRFB with the treated GF as electrodes exhibits higher coulombic, voltage and energy efficiency (98.8%, 75.1% and 74.2%) than that with the untreated GF (93.9%, 72.1% and 67.7%) at 60 mA cm −2 , and this method is even superior when compared with the reported methods

  19. Evaluation of ethyl lactate as solvent in Fenton oxidation for the remediation of total petroleum hydrocarbon (TPH)-contaminated soil.

    Science.gov (United States)

    Jalilian Ahmadkalaei, Seyedeh Pegah; Gan, Suyin; Ng, Hoon Kiat; Abdul Talib, Suhaimi

    2017-07-01

    Due to the health and environmental risks posed by the presence of petroleum-contaminated areas around the world, remediation of petroleum-contaminated soil has drawn much attention from researchers. Combining Fenton reaction with a solvent has been proposed as a novel way to remediate contaminated soils. In this study, a green solvent, ethyl lactate (EL), has been used in conjunction with Fenton's reagents for the remediation of diesel-contaminated soil. The main aim of this research is to determine how the addition of EL affects Fenton reaction for the destruction of total petroleum hydrocarbons (TPHs) within the diesel range. Specifically, the effects of different parameters, including liquid phase volume-to-soil weight (L/S) ratio, hydrogen peroxide (H 2 O 2 ) concentration and EL% on the removal efficiency, have been studied in batch experiments. The results showed that an increase in H 2 O 2 resulted in an increase in removal efficiency of TPH from 68.41% at H 2 O 2  = 0.1 M to 90.21% at H 2 O 2  = 2 M. The lowest L/S, i.e. L/S = 1, had the highest TPH removal efficiency of 85.77%. An increase in EL% up to 10% increased the removal efficiency to 96.74% for TPH, and with further increase in EL%, the removal efficiency of TPH decreased to 89.6%. EL with an optimum value of 10% was found to be best for TPH removal in EL-based Fenton reaction. The power law and pseudo-first order equations fitted well to the experimental kinetic data of Fenton reactions.

  20. Ferrocene-catalyzed heterogeneous Fenton-like degradation mechanisms and pathways of antibiotics under simulated sunlight: A case study of sulfamethoxazole.

    Science.gov (United States)

    Li, Yingjie; Zhang, Biaojun; Liu, Xiangliang; Zhao, Qun; Zhang, Heming; Zhang, Yuechao; Ning, Ping; Tian, Senlin

    2018-07-05

    Readily-available and efficient catalyst is essential for activating oxidants to produce reactive species for deeply remediating water bodies contaminated by antibiotics. In this study, Ferrocene (Fc) was introduced to establish a heterogeneous photo-Fenton system for the degradation of sulfonamide antibiotics, taking sulfamethoxazole as a representative. Results showed that the removal of sulfamethoxazole was effective in Fc-catalyzed photo-Fenton system. Electron spin resonance and radical scavenging experiments verified that there was a photoindued electron transfer process from Fc to H 2 O 2 and dissolved oxygen resulting in the formation of OH that was primarily responsible for the degradation of sulfamethoxazole. The reactions of OH with substructure model compounds of sulfamethoxazole unveiled that aniline moiety was the preferable reaction site of sulfamethoxazole, which was verified by the formation of hydroxylated product and the dimer of sulfamethoxazole in Fc-catalyzed photo-Fenton system. This heterogeneous photo-Fenton system displayed an effective degradation efficiency even in a complex water matrices, and Fc represented a long-term stability by using the catalyst for multiple cycles. These results demonstrate that Fc-catalyzed photo-Fenton oxidation may be an efficient approach for remediation of wastewater containing antibiotics. Copyright © 2018. Published by Elsevier B.V.

  1. Association of the TCF7L2 rs12255372 (G/T variant with type 2 diabetes mellitus in an Iranian population

    Directory of Open Access Journals (Sweden)

    Faranak Mahmoudi Alami

    2012-01-01

    Full Text Available In various populations worldwide, common variants of the TCF7L2 (Transcription factor 7-like 2 gene are associated with the risk of type 2 diabetes mellitus (T2DM. The aim was to investigate the association between rs12255372 (G/T polymorphism in the TCF7L2 gene and T2DM in an Iranian population. 236 unrelated patients with T2DM, and 255 normoglycemic controls without diabetes were studied. The PCR-RFLP method was used for genotyping rs12255372 (G/T polymorphism, and the SPSS version 18.0 for Windows for statistical analysis. The minor T allele of TCF7L2 rs12255372 was found to significantly increase the risk of T2DM, with an allelic odds ratio (OR of 1.458 (95% CI 1.108-1.918, p = 0.007. A significant difference in TT genotype was observed between T2DM patients and normoglycemic controls (OR 2.038, 95% CI 1.147-3.623; p = 0.014. On assuming dominant and recessive models, ORs of 1.52 [95% CI (1.05-2.21 p = 0.026] and 1.74 [95% CI (1.01-3.00 p = 0.043] were obtained, respectively, thereby implying that the co-dominant model would best fit the susceptible gene effect. This study further confirms the TCF7L2 gene as enhancing susceptibility to the development of T2DM.

  2. Bio-Electron-Fenton (BEF) process driven by microbial fuel cells for triphenyltin chloride (TPTC) degradation

    Energy Technology Data Exchange (ETDEWEB)

    Yong, Xiao-Yu; Gu, Dong-Yan; Wu, Yuan-Dong [College of Biotechnology and Pharmaceutical Engineering, Nanjing TECH University, Nanjing 211816 (China); Bioenergy Research Institute, Nanjing TECH University, Nanjing 211816 (China); Yan, Zhi-Ying [Key Laboratory of Environmental and Applied Microbiology, Environmental Microbiology, Key Laboratory of Sichuan Province, Chengdu Institute of Biology, Chinese Academy of Science, Chengdu 610041 (China); Zhou, Jun; Wu, Xia-Yuan [College of Biotechnology and Pharmaceutical Engineering, Nanjing TECH University, Nanjing 211816 (China); Bioenergy Research Institute, Nanjing TECH University, Nanjing 211816 (China); Wei, Ping [College of Biotechnology and Pharmaceutical Engineering, Nanjing TECH University, Nanjing 211816 (China); Jia, Hong-Hua [College of Biotechnology and Pharmaceutical Engineering, Nanjing TECH University, Nanjing 211816 (China); Bioenergy Research Institute, Nanjing TECH University, Nanjing 211816 (China); Zheng, Tao, E-mail: zhengtao@ms.giec.ac.cn [Guangzhou Institute of Energy Conversion, Chinese Academy of Science, Nengyuan Road, Guangzhou 510640 (China); Yong, Yang-Chun, E-mail: ycyong@ujs.edu.cn [Biofuels Institute, School of the Environment, Jiangsu University, Zhenjiang 212013 (China); Jiangsu Key Laboratory of Chemical Pollution Control and Resources Reuse, Nanjing University of Science and Technology, Nanjing 210094 (China)

    2017-02-15

    Graphical abstract: Schematic diagram of the Bio-Electron-Fenton (BEF) process for TPTC degradation. - Highlights: • A Bio-Electro-Fenton process was performed for TPTC degradation. • TPTC removal efficiency achieved 78.32 ± 2.07% within 100 h. • The TPTC degradation rate (0.775 ± 0.021 μmol L{sup −1} h{sup −1}) was much higher than previous reports. - Abstract: The intensive use of triphenyltin chloride (TPTC) has caused serious environmental pollution. In this study, an effective method for TPTC degradation was proposed based on the Bio-Electron-Fenton process in microbial fuel cells (MFCs). The maximum voltage of the MFC with graphite felt as electrode was 278.47% higher than that of carbon cloth. The electricity generated by MFC can be used for in situ generation of H{sub 2}O{sub 2} to a maximum of 135.96 μmol L{sup −1} at the Fe@Fe{sub 2}O{sub 3(*)}/graphite felt composite cathode, which further reacted with leached Fe{sup 2+} to produce hydroxyl radicals. While 100 μmol L{sup −1} TPTC was added to the cathodic chamber, the degradation efficiency of TPTC reached 78.32 ± 2.07%, with a rate of 0.775 ± 0.021 μmol L{sup −1} h{sup −1}. This Bio-Electron-Fenton driving TPTC degradation might involve in Sn−C bonds breaking and the main process is probably a stepwise dephenylation until the formation of inorganic tin and CO{sub 2}. This study provides an energy saving and efficient approach for TPTC degradation.

  3. Methyl-orange and cadmium simultaneous removal using fly ash and photo-Fenton systems

    International Nuclear Information System (INIS)

    Visa, Maria; Duta, Anca

    2013-01-01

    Highlights: ► The mixed substrates of FA-M + TiO 2 proved to be highly efficient in adsorption. ► FA-M + photo-Fenton are a low-cost material for advanced treatment of wastewater. ► The adsorbed MO may act as a complexion agent, increasing the affinity for metals. ► Dye removal by photodegradation is the favourable mechanism compared to adsorption. -- Abstract: Wastewaters resulting from the textile and dye finishing industries need complex treatment for efficient removal of colour and other compounds existent in the dyeing and rising baths (heavy metals, surfactants, equalizers, etc.). Modified fly ash (FA) mixed with TiO 2 photocatalyst represent a viable option for simultaneous removal of dyes and heavy metals, and the optimized conditions are discussed in this paper for synthetic wastewaters containing methyl-orange (MO) and cadmium. For a cost-effective dye removal process, further tests were done, replacing the photocatalyst with a (photo)Fenton system. The optimized technological parameters (contact time, amount of fly ash and amount of Fe 2+ /H 2 O 2 ) allow to reach removal efficiencies up to 88% for the heavy metal and up to 70% for the dye. The adsorption mechanisms and the process kinetic are discussed, also considering the possibility of in situ generation of the Fenton system, due to the fly ash composition

  4. Methyl-orange and cadmium simultaneous removal using fly ash and photo-Fenton systems

    Energy Technology Data Exchange (ETDEWEB)

    Visa, Maria, E-mail: visamro2000@yahoo.com [Transilvania University of Brasov, Department of Renewable Energy Systems and Recycling, Eroilor 29, 500036 Brasov (Romania); Duta, Anca, E-mail: a.duta@unitbv.ro [Transilvania University of Brasov, Department of Renewable Energy Systems and Recycling, Eroilor 29, 500036 Brasov (Romania)

    2013-01-15

    Highlights: ► The mixed substrates of FA-M + TiO{sub 2} proved to be highly efficient in adsorption. ► FA-M + photo-Fenton are a low-cost material for advanced treatment of wastewater. ► The adsorbed MO may act as a complexion agent, increasing the affinity for metals. ► Dye removal by photodegradation is the favourable mechanism compared to adsorption. -- Abstract: Wastewaters resulting from the textile and dye finishing industries need complex treatment for efficient removal of colour and other compounds existent in the dyeing and rising baths (heavy metals, surfactants, equalizers, etc.). Modified fly ash (FA) mixed with TiO{sub 2} photocatalyst represent a viable option for simultaneous removal of dyes and heavy metals, and the optimized conditions are discussed in this paper for synthetic wastewaters containing methyl-orange (MO) and cadmium. For a cost-effective dye removal process, further tests were done, replacing the photocatalyst with a (photo)Fenton system. The optimized technological parameters (contact time, amount of fly ash and amount of Fe{sup 2+}/H{sub 2}O{sub 2}) allow to reach removal efficiencies up to 88% for the heavy metal and up to 70% for the dye. The adsorption mechanisms and the process kinetic are discussed, also considering the possibility of in situ generation of the Fenton system, due to the fly ash composition.

  5. Combined photo-Fenton and biological treatment for Diuron and Linuron removal from water containing humic acid

    International Nuclear Information System (INIS)

    Farre, Maria Jose; Domenech, Xavier; Peral, Jose

    2007-01-01

    A combined chemical (photo-Fenton) and biological treatment has been proposed for Diuron and Linuron degradation in water containing natural dissolved organic matter (DOM). Humic acid (HA) was used to simulate the DOM. During the photo-Fenton process ([Fe(II)]=15.9mgL -1 , [H 2 O 2 ]=202mgL -1 , 60min of UVA irradiation time), the chemical oxygen demand (COD), total organic carbon (TOC), toxicity (EC 50 15 ) and biodegradability (BOD 5 /COD) of the generated intermediates were assessed. A reduction of photo-Fenton efficiency was observed when HA was present in solution. This effect has been explained as the result of a UVA light screening as well as a OH? radical quenching process by the HA. After the photo-Fenton process, the initial toxic and non-biodegradable herbicides were transformed into intermediates suitable for a subsequent aerobic biological treatment that was performed in a sequencing batch reactor (SBR). Complete elimination of the intermediates in presence of HA was reached at the end of the chemical-biological coupled system. Biosorption of HA onto the aerobic biomass was characterized. The results indicate that the Freundlich model adequately describes the adsorption of HA, a phenomena that follows a pseudo second-order adsorption kinetic model

  6. Combined photo-Fenton and biological treatment for Diuron and Linuron removal from water containing humic acid

    Energy Technology Data Exchange (ETDEWEB)

    Farre, Maria Jose [Departament de Quimica, Universitat Autonoma de Barcelona, 08193 Bellaterra (Spain); Domenech, Xavier [Departament de Quimica, Universitat Autonoma de Barcelona, 08193 Bellaterra (Spain); Peral, Jose [Departament de Quimica, Universitat Autonoma de Barcelona, 08193 Bellaterra (Spain)]. E-mail: jose.peral@uab.es

    2007-08-17

    A combined chemical (photo-Fenton) and biological treatment has been proposed for Diuron and Linuron degradation in water containing natural dissolved organic matter (DOM). Humic acid (HA) was used to simulate the DOM. During the photo-Fenton process ([Fe(II)]=15.9mgL{sup -1}, [H{sub 2}O{sub 2}]=202mgL{sup -1}, 60min of UVA irradiation time), the chemical oxygen demand (COD), total organic carbon (TOC), toxicity (EC{sub 50}{sup 15}) and biodegradability (BOD{sub 5}/COD) of the generated intermediates were assessed. A reduction of photo-Fenton efficiency was observed when HA was present in solution. This effect has been explained as the result of a UVA light screening as well as a OH? radical quenching process by the HA. After the photo-Fenton process, the initial toxic and non-biodegradable herbicides were transformed into intermediates suitable for a subsequent aerobic biological treatment that was performed in a sequencing batch reactor (SBR). Complete elimination of the intermediates in presence of HA was reached at the end of the chemical-biological coupled system. Biosorption of HA onto the aerobic biomass was characterized. The results indicate that the Freundlich model adequately describes the adsorption of HA, a phenomena that follows a pseudo second-order adsorption kinetic model.

  7. Efficient degradation of phenol using iron-montmorillonite as a Fenton catalyst: Importance of visible light irradiation and intermediates

    Energy Technology Data Exchange (ETDEWEB)

    Wei, Xipeng; Wu, Honghai, E-mail: wuhonghai@scnu.edu.cn; He, Guangping, E-mail: hegp@scnu.edu.cn; Guan, Yufeng

    2017-01-05

    Highlights: • Iron-montmorillonite has excellent catalytic activity on phenol Fenton degradation. • Phenol Fenton reaction follows the two-stage pseudo first order kinetic equations. • Role of visible light irradiation is more evident during induction reaction period. • Hydroquinone and catechol have a significant effect on the second-stage kinetics. - Abstract: Iron-montmorillonite (Fe-Mt) with delaminated structures was synthesized via the introduction of iron oxides into Na-montmorillonite. Fe-Mt showed significant increases in the available iron content, surface area and pore volume, along with a slight increase in the basal spacing from d{sub 001} = 1.26 (Na-Mt) to 1.53 nm (Fe-Mt). The Fenton process was efficient for phenol removal using Fe-Mt as a catalyst under visible light irradiation, and the process had two-stage pseudo-first order kinetics. The overall reaction had a higher degradation rate even when it was only irradiated with visible light for the first 40 min period. Further investigation confirmed that the irradiation increased the presence of certain intermediates. Among them, 1,4-benzoquinone, hydroquinone, and catechol all enhanced the Fenton reaction rates. Either catechol or hydroquinone was added to the Fenton system with Fe-Mt/H{sub 2}O{sub 2} with or without visible light irradiation, and they both accelerated phenol degradation because catechol and hydroquinone are capable of reductively and effectively transforming Fe(III) into Fe(II). The concentrations of dissolved total Fe increased with the increase in the oxalic acid concentration, which can strongly chelate Fe(III). Hence, iron was released from Fe-Mt, and reductive transformation played an important role in promoting the Fenton reaction process for phenol removal.

  8. Efficient degradation of phenol using iron-montmorillonite as a Fenton catalyst: Importance of visible light irradiation and intermediates

    International Nuclear Information System (INIS)

    Wei, Xipeng; Wu, Honghai; He, Guangping; Guan, Yufeng

    2017-01-01

    Highlights: • Iron-montmorillonite has excellent catalytic activity on phenol Fenton degradation. • Phenol Fenton reaction follows the two-stage pseudo first order kinetic equations. • Role of visible light irradiation is more evident during induction reaction period. • Hydroquinone and catechol have a significant effect on the second-stage kinetics. - Abstract: Iron-montmorillonite (Fe-Mt) with delaminated structures was synthesized via the introduction of iron oxides into Na-montmorillonite. Fe-Mt showed significant increases in the available iron content, surface area and pore volume, along with a slight increase in the basal spacing from d_0_0_1 = 1.26 (Na-Mt) to 1.53 nm (Fe-Mt). The Fenton process was efficient for phenol removal using Fe-Mt as a catalyst under visible light irradiation, and the process had two-stage pseudo-first order kinetics. The overall reaction had a higher degradation rate even when it was only irradiated with visible light for the first 40 min period. Further investigation confirmed that the irradiation increased the presence of certain intermediates. Among them, 1,4-benzoquinone, hydroquinone, and catechol all enhanced the Fenton reaction rates. Either catechol or hydroquinone was added to the Fenton system with Fe-Mt/H_2O_2 with or without visible light irradiation, and they both accelerated phenol degradation because catechol and hydroquinone are capable of reductively and effectively transforming Fe(III) into Fe(II). The concentrations of dissolved total Fe increased with the increase in the oxalic acid concentration, which can strongly chelate Fe(III). Hence, iron was released from Fe-Mt, and reductive transformation played an important role in promoting the Fenton reaction process for phenol removal.

  9. A microbial electro-fenton cell for removing carbamazepine in wastewater with electricity output.

    Science.gov (United States)

    Wang, Wei; Lu, Yaobin; Luo, Haiping; Liu, Guangli; Zhang, Renduo; Jin, Song

    2018-03-27

    High electrical energy is required for the electro-Fenton process to remove pharmaceuticals and personal care products (PPCPs) in wastewater. The aim of this study was to develop a novel and more cost-effective process, specifically a microbial electro-Fenton cell (MeFC), for treating PPCPs in wastewater. Acetylene black was selected as the catalyst for H 2 O 2 electrogeneration and Fe-Mn binary oxide for hydroxyl radical production. In addition to lowering energy needs, the MeFC produced a maximum power density of 112 ± 11 mW/m 2 with 1 g/L acetate as a representative substrate and 10 mg/L carbamazepine (CBZ) as a typical PPCP. Comparing with electro-Fenton process, the CBZ removal in the MeFC was 38% higher within 24 h operation (90% vs. 62%). Furthermore, the CBZ removal rate in the MeFC was 10-100 times faster than that in other biological treatment processes. Such enhanced degradation of CBZ in the MeFC was attributed to the synergistic reactions between radical oxidation of CBZ and biodegradation of degradative intermediates. The MeFC provides a promising method to remove PPCPs from wastewater coupling with efficient removal of other biodegradable organics. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. HTGR-GT and electrical load integrated control

    International Nuclear Information System (INIS)

    Chan, T.; Openshaw, F.; Pfremmer, D.

    1980-05-01

    A discussion of the control and operation of the HTGR-GT power plant is presented in terms of its closely coupled electrical load and core cooling functions. The system and its controls are briefly described and comparisons are made with more conventional plants. The results of analyses of selected transients are presented to illustrate the operation and control of the HTGR-GT. The events presented were specifically chosen to show the controllability of the plant and to highlight some of the unique characteristics inherent in this multiloop closed-cycle plant

  11. International project GT-MHR - New generation of nuclear reactors

    International Nuclear Information System (INIS)

    Vasyaev, A.; Kodochigov, N.; Kuzavkov, N.; Kuznetsov, L.

    2001-01-01

    Gas turbine-modular helium reactor (GT-MHR) is the reactor of new generation, which satisfies the requirements of the progressing large-scale nuclear power engineering. The activities in GT-MHR Project started in 1995. In 1997 the Conceptual Design was developed under four-side Agreement (MINATOM, General Atomics, FRAMATOME, Fuji Electric); it has passed through the internal and international reviews, has been approved and recommended for further development as one of new trends in creation of new generation plants. Starting from 1999, the activities in the development of the Preliminary Design of the plant were deployed under the Agreement between the Government of the United States of America and the Government of the Russian Federation on Scientific and Technical Cooperation in the Management of Plutonium That Has Been Withdrawn From Nuclear Military Programs dated July 24, 1998. The activities are established under the Contract between MINATOM and OKBM Russia, and under the General Agreement between Department of Energy (DOE), USA and OKBM. The GT-MHR Project is included into 'Development Strategy of Russian Nuclear Power in the first Half of the XXI-st Century' providing for 'the participation in an international project on the development and construction of GT-MHR nuclear power plant till year 2010 and 'operation of GT-MHR prototype unit and creation of fuel fabrication facility (within framework of International Project) till year 2030'. (author)

  12. Chelate-Modified Fenton Reaction for the Degradation of Trichloroethylene in Aqueous and Two-Phase Systems

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, Scott [Univ of KY, dept of chemical and materials engineering; lynch, Andrew [Univ of KY, dept of chemical and materials engineering; Bachas, Leonidas [Univ of KY, Dept of Chemistry; hampson, Steve [Univ of KY Center for Applied Energy Research - KY Research Consortium of Energy and Environment; Ormsbee, Lindelle [Univ of KY Center for Applied Energy Research - KY Research Consortium of Energy and Environment; Bhattacharyya, Dibakar [Univ of KY, dept of chemical and materials engineering

    2008-06-01

    The Standard Fenton reaction has been used for In-Situ Chemical Oxidation (ISCO) of toxic organics in groundwater. However, it requires low pH operating conditions, and thus has limitations for in situ applications. In addition, hydroxyl radicals are rapidly consumed by hydroxyl scavengers found in the subsurface. These problems are alleviated through the chelate-modified Fenton (hydroxyl radical) reaction, which includes the addition of nontoxic chelate (L) such as citrate or gluconic acid. This chelate allows the reaction to take place at bear neutral pH and control hydrogen peroxide consumption by binding to Fe(II), forming an FeL complex. The chelate also binds to Fe(III), preventing its precipitation as ferric hydroxide and thus prevents problems associated with injection well plugging. The rate of TCE dechlorination in chelate-modified Fenton systems is a function of pH, H2O2 concentration, and FE:L ratio. The primary objective of this research is to model and apply this process to the destruction of trichloroethylene (TCE) present in both the aqueous and organic (in the form of droplets) phases. Experimentation proved the chelate-modified Fenton reaction effectively dechlorinates TCE in both the aqueous and organic phases at near-neutral pH. Other focuses of this work include determining the effect of [L]:[Fe] ratios on H2O2 and TCE degradation as well as reusability of the FE citrate solution under repeated H2O2 injections. Generalized models were developed to predict the concentration of TCE in the aqueous phase and TCE droplet radius as a function of time using established hydroxyl radial kinetics and mass transfer relationships.

  13. Pyrite nanoparticles as a Fenton-like reagent for in situ remediation of organic pollutants

    Directory of Open Access Journals (Sweden)

    Carolina Gil-Lozano

    2014-06-01

    Full Text Available The Fenton reaction is the most widely used advanced oxidation process (AOP for wastewater treatment. This study reports on the use of pyrite nanoparticles and microparticles as Fenton reagents for the oxidative degradation of copper phthalocyanine (CuPc as a representative contaminant. Upon oxidative dissolution in water, pyrite (FeS2 particles can generate H2O2 at their surface while simultaneously promoting recycling of Fe3+ into Fe2+ and vice versa. Pyrite nanoparticles were synthesized by the hot injection method. The use of a high concentration of precursors gave individual nanoparticles (diameter: 20 nm with broader crystallinity at the outer interfaces, providing a greater number of surface defects, which is advantageous for generating H2O2. Batch reactions were run to monitor the kinetics of CuPc degradation in real time and the amount of H2O2. A markedly greater degradation of CuPc was achieved with nanoparticles as compared to microparticles: at low loadings (0.08 mg/L and 20 h reaction time, the former enabled 60% CuPc removal, whereas the latter enabled only 7% removal. These results confirm that the use of low concentrations of synthetic nanoparticles can be a cost effective alternative to conventional Fenton procedures for use in wastewater treatment, avoiding the potential risks caused by the release of heavy metals upon dissolution of natural pyrites.

  14. Notable light-free catalytic activity for pollutant destruction over flower-like BiOI microspheres by a dual-reaction-center Fenton-like process.

    Science.gov (United States)

    Wang, Liang; Yan, Dengbiao; Lyu, Lai; Hu, Chun; Jiang, Ning; Zhang, Lili

    2018-10-01

    BiOI is widely used as photocatalysts for pollutant removal, water splitting, CO 2 reduction and organic transformation due to its excellent photoelectric properties. Here, we report for the first time that a light-free catalyst consisting of the flower-like BiOI microspheres (f-BiOI MSs) exposing (1 0 1) and (1 1 0) crystal planes prepared by a hydrothermal method in ethylene glycol environment can rapidly eliminate the refractory BPA within only ∼3 min through a Fenton-like process. The reaction activity is ∼190 times higher than that of the conventional Fenton catalyst Fe 2 O 3 . A series of characterizations and experiments reveal the formation of the dual reaction centers on f-BiOI MSs. The electron-rich O centers efficiently reduce H 2 O 2 to OH, while the electron-poor oxygen vacancies capture electrons from the adsorbed pollutants and divert them to the electron-rich area during the Fenton-like reactions. By these processes, pollutants are degraded and mineralized quickly in a wide pH range. Our findings address the problems of the classical Fenton reaction and are useful for the development of efficient Fenton-like catalysts through constructing dual reaction centers. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. Wastewater treatment using hybrid treatment schemes based on cavitation and Fenton chemistry: a review.

    Science.gov (United States)

    Bagal, Manisha V; Gogate, Parag R

    2014-01-01

    Advanced oxidation processes such as cavitation and Fenton chemistry have shown considerable promise for wastewater treatment applications due to the ease of operation and simple reactor design. In this review, hybrid methods based on cavitation coupled with Fenton process for the treatment of wastewater have been discussed. The basics of individual processes (Acoustic cavitation, Hydrodynamic cavitation, Fenton chemistry) have been discussed initially highlighting the need for combined processes. The different types of reactors used for the combined processes have been discussed with some recommendations for large scale operation. The effects of important operating parameters such as solution temperature, initial pH, initial pollutant concentration and Fenton's reagent dosage have been discussed with guidelines for selection of optimum parameters. The optimization of power density is necessary for ultrasonic processes (US) and combined processes (US/Fenton) whereas the inlet pressure needs to be optimized in the case of Hydrodynamic cavitation (HC) based processes. An overview of different pollutants degraded under optimized conditions using HC/Fenton and US/Fenton process with comparison with individual processes have been presented. It has been observed that the main mechanism for the synergy of the combined process depends on the generation of additional hydroxyl radicals and its proper utilization for the degradation of the pollutant, which is strongly dependent on the loading of hydrogen peroxide. Overall, efficient wastewater treatment with high degree of energy efficiency can be achieved using combined process operating under optimized conditions, as compared to the individual process. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Ultradispersed Cobalt Ferrite Nanoparticles Assembled in Graphene Aerogel for Continuous Photo-Fenton Reaction and Enhanced Lithium Storage Performance.

    Science.gov (United States)

    Qiu, Bocheng; Deng, Yuanxin; Du, Mengmeng; Xing, Mingyang; Zhang, Jinlong

    2016-07-04

    The Photo-Fenton reaction is an advanced technology to eliminate organic pollutants in environmental chemistry. Moreover, the conversion rate of Fe(3+)/Fe(2+) and utilization rate of H2O2 are significant factors in Photo-Fenton reaction. In this work, we reported three dimensional (3D) hierarchical cobalt ferrite/graphene aerogels (CoFe2O4/GAs) composites by the in situ growing CoFe2O4 crystal seeds on the graphene oxide (GO) followed by the hydrothermal process. The resulting CoFe2O4/GAs composites demonstrated 3D hierarchical pore structure with mesopores (14~18 nm), macropores (50~125 nm), and a remarkable surface area (177.8 m(2 )g(-1)). These properties endowed this hybrid with the high and recyclable Photo-Fenton activity for methyl orange pollutant degradation. More importantly, the CoFe2O4/GAs composites can keep high Photo-Fenton activity in a wide pH. Besides, the CoFe2O4/GAs composites also exhibited excellent cyclic performance and good rate capability. The 3D framework can not only effectively prevent the volume expansion and aggregation of CoFe2O4 nanoparticles during the charge/discharge processes for Lithium-ion batteries (LIBs), but also shorten lithium ions and electron diffusion length in 3D pathways. These results indicated a broaden application prospect of 3D-graphene based hybrids in wastewater treatment and energy storage.

  17. In-situ treatment of PCP contaminated soil by electrokinetics-Fenton-biodegradation process

    Energy Technology Data Exchange (ETDEWEB)

    Yang, G.C.C.; Chen Jenteh [Inst. of Environmental Engineering, National Sun Yat-Sen Univ., Kaohsiung (Taiwan)

    2001-07-01

    This laboratory investigation was conducted to evaluate the treatment efficiency of a process combining electrokinetic remediation (EK), Fenton process, and biodegradation for treating a pentachlorophenol (PCP) contaminated soil. For EK-Fenton experiments, the results have indicated that an increase of treatment time (e.g., from 10 to 15 days) would substantially increase the overall treatment (i.e., removal and destruction) efficiency of PCP. Only a limited increase of the treatment efficiency would be found if the concentration of FeSO{sub 4} was increased from 0.0196M to 0.098M. When scrap iron power was employed as the catalyst, the residual PCP concentration for soil near the anode end was found to be lower than that of 0.0196M FeSO{sub 4}. But its overall treatment efficiency was only 56.58%, which is lower than 68.34% obtained by using 0.0196M FeSO{sub 4} and 0.35% H{sub 2}O{sub 2}. When H{sub 2}O{sub 2} concentration was further increased to 3.5%, an overall treatment efficiency of 79.77% would be obtained when 0.0196M FeSO{sub 4} was used. When treated by EK-biodegradation process with phenol enrichment bacteria, the overall treatment efficiency of PCP was as low as 25.67%. If PCP contaminated soil was pre-treated by EK-Fenton process and followed by EK-biodegradation, an overall treatment efficiency of 100% was found to be achievable. (orig.)

  18. Dynamics and control modeling of the closed-cycle gas turbine (GT-HTGR) power plant

    International Nuclear Information System (INIS)

    Bardia, A.

    1980-02-01

    The simulation if presented for the 800-MW(e) two-loop GT-HTGR plant design with the REALY2 transient analysis computer code, and the modeling of control strategies called for by the inherently unique operational requirements of a multiple loop GT-HTGR is described. Plant control of the GT-HTGR is constrained by the nature of its power conversion loops (PCLs) in which the core cooling flow and the turbine flow are directly related and thus changes in flow affect core cooling as well as turbine power. Additionally, the high thermal inertia of the reactor core precludes rapid changes in the temperature of the turbine inlet flow

  19. Enhancement of oxygen diffusion process on a rotating disk electrode for the electro-Fenton degradation of tetracycline

    International Nuclear Information System (INIS)

    Zhang, Yan; Gao, Ming-Ming; Wang, Xin-Hua; Wang, Shu-Guang; Liu, Rui-Ting

    2015-01-01

    An electro-Fenton process was developed for wastewater treatment in which hydrogen peroxide was generated in situ with a rotating graphite disk electrode as cathode. The maximum H 2 O 2 generation rate for the RDE reached 0.90 mg/L/h/cm 2 under the rotation speed of 400 rpm at pH 3, and −0.8 V vs SCE. The performance of this electro-Fenton reactor was assessed by tetracycline degradation in an aqueous solution. Experimental results showed the rotation of disk cathode resulted in the efficient production of H 2 O 2 without oxygen aeration, and excellent ability for degrading organic pollutants compared to the electro-Fenton system with fixed cathode. Tetracycline of 50 mg/L was degraded completely within 2 h with the addition of ferrous ion (1.0 mM). The chronoamperometry analysis was employed to investigate the oxygen diffusion on the rotating cathode. The results demonstrated that the diffusion coefficients of dissolved oxygen is 19.45 × 10 −5 cm 2 /s, which is greater than that reported in the literature. Further calculation indicated that oxygen is able to diffuse through the film on the rotating cathode within the contact time in each circle. This study proves that enhancement of oxygen diffusion on RDE is benefit for H 2 O 2 generation, thus provides a promising method for organic pollutants degradation by the combination of RDE with electro-Fenton reactor and offers a new insight on the oxygen transform process in this new system.

  20. Treatment of landfill leachate using a combined stripping, Fenton, SBR, and coagulation process

    International Nuclear Information System (INIS)

    Guo Jinsong; Abbas, Abdulhussain A.; Chen Youpeng; Liu Zhiping; Fang Fang; Chen Peng

    2010-01-01

    The leachate from Changshengqiao landfill (Chongqing, China) was characterized and submitted to a combined process of air stripping, Fenton, sequencing batch reactor (SBR), and coagulation. Optimum operating conditions for each process were identified. The performance of the treatment was assessed by monitoring the removal of organic matter (COD and BOD 5 ) and ammonia nitrogen (NH 3 -N). It has been confirmed that air stripping (at pH 11.0 and aeration time 18 h) effectively removed 96.6% of the ammonia. The Fenton process was investigated under optimum conditions (pH 3.0, FeSO 4 .7H 2 O of 20 g l -1 and H 2 O 2 of 20 ml l -1 ), COD removal of up to 60.8% was achieved. Biodegradability (BOD 5 /COD ratio) increased from 0.18 to 0.38. Thereafter the Fenton effluent was mixed with sewage at dilutions to a ratio of 1:3 before it was subjected to the SBR reactor; under the optimum aeration time of 20 h, up to 82.8% BOD 5 removal and 83.1% COD removal were achieved. The optimum coagulant (Fe 2 (SO 4 ) 3 ) was a dosage of 800 mg l -1 at pH of 5.0, which reduced COD to an amount of 280 mg l -1 . These combined processes were successfully employed and very effectively decreased pollutant loading.

  1. Efficient treatment of aniline containing wastewater in bipolar membrane microbial electrolysis cell-Fenton system.

    Science.gov (United States)

    Li, Xiaohu; Jin, Xiangdan; Zhao, Nannan; Angelidaki, Irini; Zhang, Yifeng

    2017-08-01

    Aniline-containing wastewater can cause significant environmental problems and threaten the humans's life. However, rapid degradation of aniline with cost-efficient methods remains a challenge. In this work, a novel microbial electrolysis cell with bipolar membrane was integrated with Fenton reaction (MEC-Fenton) for efficient treatment of real wastewater containing a high concentration (4460 ± 52 mg L -1 ) of aniline. In this system, H 2 O 2 was in situ electro-synthesized from O 2 reduction on the graphite cathode and was simultaneously used as source of OH for the oxidation of aniline wastewater under an acidic condition maintained by the bipolar membrane. The aniline was effectively degraded following first-order kinetics at a rate constant of 0.0166 h -1 under an applied voltage of 0.5 V. Meanwhile, a total organic carbon (TOC) removal efficiency of 93.1 ± 1.2% was obtained, revealing efficient mineralization of aniline. The applicability of bipolar membrane MEC-Fenton system was successfully demonstrated with actual aniline wastewater. Moreover, energy balance showed that the system could be a promising technology for removal of biorefractory organic pollutants from wastewaters. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Optimal Condition of Fenton's Reagent to Enhance the Alcohol Production from Palm Oil Mill Effluent (POME

    Directory of Open Access Journals (Sweden)

    Supawadee Sinnaraprasat

    2011-07-01

    Full Text Available Application of Fenton's reaction for a proper hydrolysis step is an essential and important step in obtaining a higher level of readily biodegradable sugars from palm oil mill effluent (POME for improving the alcohol production by using immobilized Clostridium acetobutylicum. The objective of this research was, therefore, to investigate the optimum condition of Fenton's reaction in terms of COD: H2O2 ratios (w/w and H2O2: Fe2+ ratios (molar ratio used to oxidize carbohydrate and high molecular organic compounds into simple sugars, which are further fermented into alcohol. The experiments were carried out at H2O2: Fe2+ ratios (molar ratios of 5, 10, 20, 30 and 40 and the COD: H2O2 ratios (w/w of 50, 70, 100 and 130 (initial COD about 50,000 mg/L. The total sugar concentrations and organic compounds biodegradability (BOD5/COD ratios were also used for investigating suitable conditions for Fenton's reaction. The concentration of Fenton's reagent at H2O2:Fe2+ and COD:H2O2 ratio of 20 and 130 was identified as the optimum operating condition for the highest simple sugars of about 0.865% and BOD5/COD ratios of 0.539. The alcohol productions were carried out in the continuous stirred tank reactors (CSTR under an anaerobic continuous immobilization system. At a hydraulic retention time of 12 hours and POME pH of 4.8, the maximum total ABE concentration of 495 mg/L and the ABE yield of 0.236 grams of ABE produced/gram of reducing sugars were achieved at the mixed polyvinyl alcohol (PVA and palm oil ash (POA ratio of 10 : 3.

  3. Design of a visible light driven photo-electrochemical/electro-Fenton coupling oxidation system for wastewater treatment

    International Nuclear Information System (INIS)

    Ding, Xing; Ai, Zhihui; Zhang, Lizhi

    2012-01-01

    Highlights: ► Coupling PEC and EF oxidation significantly improves pollutant degradation efficiency. ► The degradation of the PEC/EF system was increased by 154%. ► The instantaneous current efficiency of the PEC/EF system was increased by 26%. - Abstract: In this study, we report on a photo-electrochemical/electro-Fenton oxidation (PEC/EF) system by coupling visible light driven photo-electrochemical oxidation (PEC) and electro-Fenton oxidation (EF) in an undivided cell. Bi 2 WO 6 nanoplates deposited on FTO glass (Bi 2 WO 6 /FTO) and Fe-Fe 2 O 3 core–shell nanowires supported on activated carbon fiber (Fe-Fe 2 O 3 /ACF) were used as the anode and the cathode in the PEC/EF system, respectively. This novel PEC/EF system showed much higher activity than the single PEC and EF systems on degradation of rhodamine B in aqueous solution at natural pH. Moreover, the degradation and the instantaneous current efficiencies of the PEC/EF system were increased by 154% and 26% in comparison with the sum of those of single PEC and EF systems, respectively. These significant enhancements could be attributed to the synergetic effect from better separation of photo-generated carriers in the photo-anode and the transfer of photo-electrons to the oxygen diffusion cathode to generate more electro-generated H 2 O 2 and hydroxyl radicals on the Fenton cathode. The better separation of photo-generated carriers contribute more to the overall degradation enhancement than the photo-electrons generated H 2 O 2 and the subsequent Fenton reaction on the cathode during the PEC/EF process.

  4. Estrogen modulates potassium currents and expression of the Kv4.2 subunit in GT1-7 cells.

    Science.gov (United States)

    Farkas, Imre; Varju, Patricia; Liposits, Zsolt

    2007-03-01

    The proper maintenance of reproduction requires the pulsatile secretion of gonadotropin-releasing hormone (GnRH), which is ensured by synchronized periodic firing of multiple GnRH neurons. Both hormone secretion and electrophysiological properties of GnRH cells are influenced by estrogen. The impact of 17beta-estradiol treatment on the function of voltage gated A- and K-type potassium channels, known modulators of firing rate, was therefore examined in our experiments using immortalized GnRH-producing GT1-7 neurons. Whole cell patch clamp recordings showed the absence of the A-type current in GT1-7 cells cultured in estrogen-free medium and after 8h 17beta-estradiol treatment. Exposure of the cells to 17beta-estradiol for 24 and 48 h, respectively, resulted in the appearance of the A-type current. The induction of the A-type current by 17beta-estradiol was dose-related (50 pM to 15 nM range). In contrast, the K-type potassium current was apparent in the estrogen-free environment and 17beta-estradiol administration significantly decreased its amplitude. Co-administration of 17beta-estradiol and estrogen receptor blocker, Faslodex (ICI 182,780; 1 microM) abolished the occurrence of the A-type current. Real-time PCR data demonstrated that expression of the Kv4.2 subunit of the A-type channel was low at 0, 0.5, 2 and 8h, peaked at 24h and diminished at 48 h 17beta-estradiol treatment (15 nM). These data indicate that potassium channels of GT1-7 neurons are regulated by estrogen a mechanism that might contribute to modulation of firing rate and hormone secretion in GnRH neurons.

  5. IRON OPTIMIZATION FOR FENTON-DRIVEN OXIDATION OF MTBE-SPENT GRANULAR ACTIVATED CARBON

    Science.gov (United States)

    Fenton-driven chemical regeneration of granular activated carbon (GAC) is accomplished through the addition of H2O2 and iron (Fe) to spent GAC. The overall objective of this treatment process is to transform target contaminants into less toxic byproducts, re-establish the sorpti...

  6. Mechanism and Parameter Optimization of Fenton's Reagent Integrated with Surfactant Pretreatment to Improve Sludge Dewaterability.

    Directory of Open Access Journals (Sweden)

    Yi Xing

    Full Text Available Sludge dewatering can effectively reduce the volume and mass of sludge for subsequent treatment and disposal. The work validated the potential of Fenton's reagent combined with dodecyl dimethyl benzyl ammonium chloride (DDBAC in improving sludge dewaterability and proposed the mechanism of joint conditioning. The composite conditioner dosage was optimized using response surface methodology. Results indicated the good conditioning capability of the composite conditioners. The optimum dosages for H2O2, Fe2+, and DDBAC were 44.6, 39.6, and 71.0 mg/g, respectively, at which a sludge cake water content of 59.67% could be achieved. Moreover, a second-order polynomial equation was developed to describe the behavior of joint conditioning. Analysis of the reaction mechanism showed that Fenton oxidation effectively decomposed extracellular polymeric substance (EPS, including loosely bound EPS (LB-EPS and tightly bound EPS (TB-EPS, into dissolved organics, such as proteins and polysaccharides. The process facilitated the conversion of the bound water into free water. Furthermore, DDBAC further released the bound water through solubilization of TB-EPS and LB-EPS after the Fenton reaction. The bound water content of the sludge conditioned with Fenton's reagent decreased from 3.15 to 1.36 g/g and further decreased to 1.08 g/g with the addition of DDBAC. High-performance liquid chromatography analysis verified that the composite conditioning could oxidize and hydrolyze EPS into low-molecular-mass organics (e.g., formic and acetic acid, thereby facilitating the release of bound water.

  7. Enzymatic in-situ generation of H2O2 for decolorization of Acid Blue 113 by fenton process

    Directory of Open Access Journals (Sweden)

    Karimi Afzal

    2012-01-01

    Full Text Available Decolorization of Acid Blue 113 in an aqueous medium by bio-Fenton process has been investigated in this research. Enzymatic oxidation of glucose was performed to in-situ generation of H2O2 which was employed to react with Fe2+ for producing hydroxyl radicals. The effect of various parameters include concentrations of 113, glucose, and FeSO4, activity of glucose oxidase (GOx and the effect of pH were assessed. The highest decolorization of AB 113 were achieved at Fe2+ concentration of 0.2 mmol/L, pH =4.0, glucose concentration of 0.018 mol/L, and glucose oxidase activity of 2500 U/L in the constant temperature (23 ±0.1ºC and constant shaking rate (160 r/min, while the concentration of 113 was 40 mg/L. In these conditions, 113 decolorization efficiency after 60 min was obtained about 95%.

  8. Use of Enzymatic Bio-Fenton as a New Approach in Decolorization of Malachite Green

    Science.gov (United States)

    Karimi, Afzal; Aghbolaghy, Mostafa; Khataee, Alireza; Shoa Bargh, Shabnam

    2012-01-01

    An enzymatic reaction using glucose oxidase was applied for in situ production of hydrogen peroxide for use in simultaneously Fenton's reaction in decolorization of malachite green. It was found that decolorization rate increased by increasing of glucose concentration from 0.2 g/L to 1.5 g/L. Decolorization rate showed different behaviors versus temperature changes. Initial rate of decolorization process was increased by increasing of temperature; after 30 minutes, especially at temperatures above 30°C, the decolorization rate was gradually reduced. The pH value in the reaction media was decreased from natural to about pH = 3 which had synergic effect on the Fenton process by stabilizing of Fe2+ ions. PMID:22649310

  9. Natural soil mediated photo Fenton-like processes in treatment of pharmaceuticals: Batch and continuous approach.

    Science.gov (United States)

    Changotra, Rahil; Rajput, Himadri; Dhir, Amit

    2017-12-01

    This paper manifests the potential viability of soil as a cost-free catalyst in photo-Fenton-like processes for treating pharmaceuticals at large scale. Naturally available soil without any cost intensive modification was utilized as a catalyst to degrade pharmaceuticals, specifically ornidazole (ORZ) and ofloxacin (OFX). Soil was characterized and found enriched with various iron oxides like hematite, magnetite, goethite, pyrite and wustite, which contributes toward enhanced dissolution of Fe 3+ than Fe 2+ in the aqueous solution resulting in augmented rate of photo-Fenton reaction. The leached iron concentration in solution was detected during the course of experiments. The degradation of ORZ and OFX was assessed in solar induced batch experiments using H 2 O 2 as oxidant and 95% ORZ and 92% OFX removal was achieved. Elevated efficiencies were achieved due to Fe 2+ /Fe 3+ cycling, producing more hydroxyl radical leading to the existence of homogeneous and heterogeneous reactions simultaneously. The removal efficiency of solar photo-Fenton like process was also compared to photo-Fenton process with different irradiation sources (UV-A and UV-B) and were statistically analysed. Continuous-scale studies were conducted employing soil either in the form of soil beads or as a thin layer spread on the surface of baffled reactor. Soil beads were found to have satisfactory reusability and stability. 84 and 79% degradation of ORZ and OFX was achieved using soil as thin layer while with soil beads 71 and 68% degradation, respectively. HPLC and TOC study confirmed the efficient removal of both the compounds. Toxicity assessment demonstrates the inexistence of toxic intermediates during the reaction. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Electro-Fenton decolourisation of dyes in an airlift continuous reactor using iron alginate beads.

    Science.gov (United States)

    Iglesias, O; Rosales, E; Pazos, M; Sanromán, M A

    2013-04-01

    In this study, electro-Fenton dye degradation was performed in an airlift continuous reactor configuration by harnessing the catalytic activity of Fe alginate gel beads. Electro-Fenton experiments were carried out in an airlift reactor with a working volume of 1.5 L, air flow of 1.5 L/min and 115 g of Fe alginate gel beads. An electric field was applied by two graphite bars connected to a direct current power supply with a constant potential drop. In this study, Lissamine Green B and Reactive Black 5 were selected as model dyes. Fe alginate gel beads can be used as an effective heterogeneous catalyst for the degradation of organic dyes in the electro-Fenton process, as they are more efficient than the conventional electrochemical techniques. At optimal working conditions (3 V and pH 2), the continuous process was performed. For both dyes, the degree of decolourisation increases when the residence time augments. Taking into account hydrodynamic and kinetic behaviour, a model to describe the reactor profile was obtained, and the standard deviation between experimental and theoretical data was lower than 6%. The results indicate the suitability of the electro-Fenton technique to oxidise polluted effluents in the presence of Fe alginate gel beads. Moreover, the operation is possible in a continuous airlift reactor, due to the entrapment of iron in the alginate matrix.

  11. Comparative study on the removal of COD from POME by electrocoagulation and electro-Fenton methods: Process optimization

    Science.gov (United States)

    Chairunnisak, A.; Arifin, B.; Sofyan, H.; Lubis, M. R.; Darmadi

    2018-03-01

    This research focuses on the Chemical Oxygen Demand (COD) treatment in palm oil mill effluent by electrocoagulation and electro-Fenton methods to solve it. Initially, the aqueous solution precipitates in acid condition at pH of about two. This study focuses on the palm oil mill effluent degradation by Fe electrodes in a simple batch reactor. This work is conducted by using different parameters such as voltage, electrolyte concentration of NaCl, volume of H2O2 and operation time. The processing of data resulted is by using response surface method coupled with Box-Behnken design. The electrocoagulation method results in the optimum COD reduction of 94.53% from operating time of 39.28 minutes, 20 volts, and without electrolyte concentration. For electro-Fenton process, experiment points out that voltage 15.78 volts, electrolyte concentration 0.06 M and H2O2 volume 14.79 ml with time 35.92 minutes yield 99.56% degradation. The result concluded that the electro-Fenton process was more effective to degrade COD of the palm-oil-mill effluent compared to electrocoagulation process.

  12. Fenton process combined with coagulation for the treatment of black liquor from bioethanol wastewater

    Science.gov (United States)

    Muryanto, Muryanto; Hanifah, Ummu; Amriani, Feni; Ibadurrahman, Ahmad Faiz; Sari, Ajeng Arum

    2017-11-01

    High amounts of black liquor are generated from bioethanol production by using oil palm empty fruit bunches. The black liquor is waste from alkaline pretreatment, it contains high amount of an alkaline solution (NaOH). The black liquor wastewater was highly contaminated with organic materials, and quite toxic for aquatic ecosystems if discharged directly into waters. This study aimed to determine ability of Fenton process combined with coagulation to treat black liquor. The addition 5% of polyaluminium chloride (PAC) could decolorized black liquor, degraded lignin, and produced sludge 70.64%, 68.28%, and 2.76 gram, respectively. Decolorization of black liquor was in line with degradation of black liquor because lignin is the main compound in black liquor. SEM images after addition of PAC of 5% indicated fragmentation of structure. Fenton reagent consist of 0.7 M FeSO4+ 3M H2O2 has able to decolorize black liquor, degrade lignin, and produce sludge 51.67% and 25.44%, and 0.44 gram, respectively. It was concluded that black liquor wastewater from bioethanol can be treated by using Fenton process combined with coagulation. However, these methods still need improvement to obtain the higher degradation rate, and coagulation sludge needs further consideration.

  13. Analogies and differences among bacterial and viral disinfection by the photo-Fenton process at neutral pH: a mini review.

    Science.gov (United States)

    Giannakis, Stefanos

    2017-12-19

    Over the last years, the photo-Fenton process has been established as an effective, green alternative to chemical disinfection of waters and wastewaters. Microorganisms' inactivation is the latest success story in the application of this process at near-neutral pH, albeit without clearly elucidated inactivation mechanisms. In this review, the main pathways of the combined photo-Fenton process against the most frequent pathogen models (Escherichia coli for bacteria and MS2 bacteriophage for viruses) are analyzed. Firstly, the action of solar light is described and the specific inactivation mechanisms in bacteria (internal photo-Fenton) and viruses (genome damage) are presented. The contribution of the external pathways due to the potential presence of organic matter in generating reactive oxygen species (ROS) and their effects on microorganism inactivation are discussed. Afterwards, the effects of the gradual addition of Fe and H 2 O 2 are assessed and the differences among bacterial and viral inactivation are highlighted. As a final step, the simultaneous addition of both reagents induces the photo-Fenton in the bulk, focusing on the differences induced by the homogeneous or heterogeneous fraction of the process and the variation among the two respective targets. This work exploits the accumulated evidence on the mechanisms of bacterial inactivation and the scarce ones towards viral targets, aiming to bridge this knowledge gap and make possible the further application of the photo-Fenton process in the field of water/wastewater treatment.

  14. Efficient Destruction of Pollutants in Water by a Dual-Reaction-Center Fenton-like Process over Carbon Nitride Compounds-Complexed Cu(II)-CuAlO2.

    Science.gov (United States)

    Lyu, Lai; Yan, Dengbiao; Yu, Guangfei; Cao, Wenrui; Hu, Chun

    2018-04-03

    Carbon nitride compounds (CN) complexed with the in-situ-produced Cu(II) on the surface of CuAlO 2 substrate (CN-Cu(II)-CuAlO 2 ) is prepared via a surface growth process for the first time and exhibits exceptionally high activity and efficiency for the degradation of the refractory pollutants in water through a Fenton-like process in a wide pH range. The reaction rate for bisphenol A removal is ∼25 times higher than that of the CuAlO 2 . According to the characterization, Cu(II) generation on the surface of CuAlO 2 during the surface growth process results in the marked decrease of the surface oxygen vacancies and the formation of the C-O-Cu bridges between CN and Cu(II)-CuAlO 2 in the catalyst. The electron paramagnetic resonance (EPR) analysis and density functional theory (DFT) calculations demonstrate that the dual reaction centers are produced around the Cu and C sites due to the cation-π interactions through the C-O-Cu bridges in CN-Cu(II)-CuAlO 2 . During the Fenton-like reactions, the electron-rich center around Cu is responsible for the efficient reduction of H 2 O 2 to • OH, and the electron-poor center around C captures electrons from H 2 O 2 or pollutants and diverts them to the electron-rich area via the C-O-Cu bridge. Thus, the catalyst exhibits excellent catalytic performance for the refractory pollutant degradation. This study can deepen our understanding on the enhanced Fenton reactivity for water purification through functionalizing with organic solid-phase ligands on the catalyst surface.

  15. Fenton-enhanced {gamma}-radiolysis of cyanuric acid

    Energy Technology Data Exchange (ETDEWEB)

    Varghese, Rani [School of Chemical Sciences, Mahatma Gandhi University, Kottayam 686560, Kerala (India); Aravind, Usha K. [School of Chemical Sciences, Mahatma Gandhi University, Kottayam 686560, Kerala (India); Aravindakumar, Charuvila T. [School of Chemical Sciences, Mahatma Gandhi University, Kottayam 686560, Kerala (India)]. E-mail: CT-Aravindakumar@rocketmail.com

    2007-04-02

    Degradation of cyanuric acid (OOOT), a stable end product of oxidative decomposition of atrazine, is investigated in a combined field of gamma radiolysis and fenton reaction. The reaction of hydroxyl radical ({center_dot}OH) at pH 6 was carried out by irradiating N{sub 2}O saturated aqueous solutions containing OOOT (1 x 10{sup -3} mol dm{sup -3}), and this resulted only a marginal degradation (20%). However, when the same reaction was carried out in the presence of varying concentrations of ferrous sulfate ((5-10) x 10{sup -5} mol dm{sup -3}), the decay of OOOT has been enhanced to more than 80%. This decay followed a first order kinetics. Nearly similar effects were observed with another triazine derivative, 2,4-dioxohexahydro-1,3,5-triazine (DHT). Two major reaction mechanisms are proposed for the enhanced decay of OOOT. The formation of unstable hydroxyl radical adducts from the reaction of {center_dot}OH which is the result of gamma radiolysis and the Fenton reaction (resulting from the reaction of the added Fe(II) and of the H{sub 2}O{sub 2} from the radiolysis of water), is proposed as the first mechanism. The second mechanism, which is likely the major contributor to degradation, is proposed as the reaction of a nucleophilic adduct, Fe(II)OOH, which could directly react with the electron deficient triazine ring. It is highlighted that such degradation reactions must be explored for the complete degradation of the byproducts of the oxidative decomposition of atrazine.

  16. Iron oxide nanotube layer fabricated with electrostatic anodization for heterogeneous Fenton like reaction

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Jun-Won; Park, Jae-Woo, E-mail: jaewoopark@hanyang.ac.kr

    2014-05-01

    Highlights: • Iron oxide nanotube was newly fabricated with potentiostatic anodization of Fe{sup 0} foil. • Cyanide was oxidized more effectively with the iron oxide nanotube and H{sub 2}O{sub 2}, resulting in fast oxidation of cyanide and cyanate. • This nanotube of Fe{sub 2}O{sub 3} on Fe{sup 0} metal can replace conventional particulate iron catalysts in Fenton-like processes. - Abstract: Iron oxide nanotubes (INT) were fabricated with potentiostatic anodization of zero valent iron foil in 1 M Na{sub 2}SO{sub 4} containing 0.5 wt% NH{sub 4}F electrolyte, holding the potential at 20, 40, and 60 V for 20 min, respectively. Field emission scanning electron microscopy and X-ray diffractometry were used to evaluate the morphology and crystalline structure of the INT film. The potential of 40 V for 20 min was observed to be optimal to produce an optimal catalytic film. Cyanide dissolved in water was degraded through the Fenton-like reaction using the INT film with hydrogen peroxide (H{sub 2}O{sub 2}). In case of INT-40 V in the presence of H{sub 2}O{sub 2} 3%, the first-order rate constant was found to be 1.7 × 10{sup −2} min{sup −1}, and 1.2 × 10{sup −2} min{sup −1} with commercial hematite powder. Degradation of cyanide was much less with only H{sub 2}O{sub 2}. Therefore, this process proposed in this work can be an excellent alternative to traditional catalysts for Fenton-like reaction.

  17. Treatment of landfill leachate using a combined stripping, Fenton, SBR, and coagulation process

    Energy Technology Data Exchange (ETDEWEB)

    Guo Jinsong, E-mail: guo0768@cqu.edu.cn [Faculty of Urban Construction and Environmental Engineering, Key Laboratory of the Three Gorges Reservoir Region' s Eco-Environment, Chongqing University, Chongqing 400045 (China); Abbas, Abdulhussain A. [Faculty of Urban Construction and Environmental Engineering, Key Laboratory of the Three Gorges Reservoir Region' s Eco-Environment, Chongqing University, Chongqing 400045 (China); Faculty of Engineering, Basrah University, Basrah (Iraq); Chen Youpeng; Liu Zhiping; Fang Fang; Chen Peng [Faculty of Urban Construction and Environmental Engineering, Key Laboratory of the Three Gorges Reservoir Region' s Eco-Environment, Chongqing University, Chongqing 400045 (China)

    2010-06-15

    The leachate from Changshengqiao landfill (Chongqing, China) was characterized and submitted to a combined process of air stripping, Fenton, sequencing batch reactor (SBR), and coagulation. Optimum operating conditions for each process were identified. The performance of the treatment was assessed by monitoring the removal of organic matter (COD and BOD{sub 5}) and ammonia nitrogen (NH{sub 3}-N). It has been confirmed that air stripping (at pH 11.0 and aeration time 18 h) effectively removed 96.6% of the ammonia. The Fenton process was investigated under optimum conditions (pH 3.0, FeSO{sub 4}.7H{sub 2}O of 20 g l{sup -1} and H{sub 2}O{sub 2} of 20 ml l{sup -1}), COD removal of up to 60.8% was achieved. Biodegradability (BOD{sub 5}/COD ratio) increased from 0.18 to 0.38. Thereafter the Fenton effluent was mixed with sewage at dilutions to a ratio of 1:3 before it was subjected to the SBR reactor; under the optimum aeration time of 20 h, up to 82.8% BOD{sub 5} removal and 83.1% COD removal were achieved. The optimum coagulant (Fe{sub 2}(SO{sub 4}){sub 3}) was a dosage of 800 mg l{sup -1} at pH of 5.0, which reduced COD to an amount of 280 mg l{sup -1}. These combined processes were successfully employed and very effectively decreased pollutant loading.

  18. Treatment of pesticide wastewater by moving-bed biofilm reactor combined with Fenton-coagulation pretreatment

    Energy Technology Data Exchange (ETDEWEB)

    Chen Sheng [School of Municipal and Environmental Engineering, Harbin Institute of Technology, Harbin 150090 (China)]. E-mail: hitchensheng@126.com; Sun Dezhi [School of Municipal and Environmental Engineering, Harbin Institute of Technology, Harbin 150090 (China); Chung, J.-S. [School of Municipal and Environmental Engineering, Harbin Institute of Technology, Harbin 150090 (China); Department of Chemical Engineering, Pohang University of Science and Technology, Pohang 790-784 (Korea, Republic of)

    2007-06-01

    In order to treat pesticide wastewater having high chemical oxygen demand (COD) value and poor biodegradability, Fenton-coagulation process was first used to reduce COD and improve biodegradability and then was followed by biological treatment. Optimal experimental conditions for the Fenton process were determined to be Fe{sup 2+} concentration of 40 mmol/L and H{sub 2}O{sub 2} dose of 97 mmol/L at initial pH 3. The interaction mechanism of organophosphorous pesticide and hydroxyl radicals was suggested to be the breakage of the P=S double bond and formation of sulfate ions and various organic intermediates, followed by formation of phosphate and consequent oxidation of intermediates. For the subsequent biological treatment, 3.2 g/L Ca(OH){sub 2} was added to adjust the pH and further coagulate the pollutants. The COD value could be evidently decreased from 33,700 to 9300 mg/L and the ratio of biological oxygen demand (BOD{sub 5}) to COD of the wastewater was enhanced to over 0.47 by Fenton oxidation and coagulation. The pre-treated wastewater was then subjected to biological oxidation by using moving-bed biofilm reactor (MBBR) inside which tube chip type bio-carriers were fluidized upon air bubbling. Higher than 85% of COD removal efficiency could be achieved when the bio-carrier volume fraction was kept more than 20% by feeding the pretreated wastewater containing 3000 mg/L of inlet COD at one day of hydraulic retention time (HRT), but a noticeable decrease in the COD removal efficiency when the carrier volume was decreased down to 10%, only 72% was observed. With the improvement of biodegradability by using Fenton pretreatment, also due to the high concentration of biomass and high biofilm activity using the fluidizing bio-carriers, high removal efficiency and stable operation could be achieved in the biological process even at a high COD loading of 37.5 gCOD/(m{sup 2} carrier day)

  19. Treatment of pesticide wastewater by moving-bed biofilm reactor combined with Fenton-coagulation pretreatment

    International Nuclear Information System (INIS)

    Chen Sheng; Sun Dezhi; Chung, J.-S.

    2007-01-01

    In order to treat pesticide wastewater having high chemical oxygen demand (COD) value and poor biodegradability, Fenton-coagulation process was first used to reduce COD and improve biodegradability and then was followed by biological treatment. Optimal experimental conditions for the Fenton process were determined to be Fe 2+ concentration of 40 mmol/L and H 2 O 2 dose of 97 mmol/L at initial pH 3. The interaction mechanism of organophosphorous pesticide and hydroxyl radicals was suggested to be the breakage of the P=S double bond and formation of sulfate ions and various organic intermediates, followed by formation of phosphate and consequent oxidation of intermediates. For the subsequent biological treatment, 3.2 g/L Ca(OH) 2 was added to adjust the pH and further coagulate the pollutants. The COD value could be evidently decreased from 33,700 to 9300 mg/L and the ratio of biological oxygen demand (BOD 5 ) to COD of the wastewater was enhanced to over 0.47 by Fenton oxidation and coagulation. The pre-treated wastewater was then subjected to biological oxidation by using moving-bed biofilm reactor (MBBR) inside which tube chip type bio-carriers were fluidized upon air bubbling. Higher than 85% of COD removal efficiency could be achieved when the bio-carrier volume fraction was kept more than 20% by feeding the pretreated wastewater containing 3000 mg/L of inlet COD at one day of hydraulic retention time (HRT), but a noticeable decrease in the COD removal efficiency when the carrier volume was decreased down to 10%, only 72% was observed. With the improvement of biodegradability by using Fenton pretreatment, also due to the high concentration of biomass and high biofilm activity using the fluidizing bio-carriers, high removal efficiency and stable operation could be achieved in the biological process even at a high COD loading of 37.5 gCOD/(m 2 carrier day)

  20. Magnetic diatomite(Kieselguhr)/Fe2O3/TiO2 composite as an efficient photo-Fenton system for dye degradation

    Science.gov (United States)

    Barbosa, Isaltino A.; Zanatta, Lucas D.; Espimpolo, Daniela M.; da Silva, Douglas L.; Nascimento, Leandro F.; Zanardi, Fabrício B.; de Sousa Filho, Paulo C.; Serra, Osvaldo A.; Iamamoto, Yassuko

    2017-10-01

    We explored the potential use of diatomite/Fe2O3/TiO2 composites as catalysts for heterogeneous photo-Fenton degradation of methylene blue under neutral pH. Such system consists in magnetic solids synthesized by co-precipitation with Fe2+/Fe3+ in the presence of diatomite, followed by impregnation of TiO2. The results showed that the optimal amount of the catalyst was 2.0 g L-1, since aggregation phenomena become significant above this concentration, which decreases the photodegradation activity. The catalyst is highly efficient in the degradation of methylene blue and shows an easy recovery by an external magnetic field. This allows for an effective catalyst reuse without significant loss of activity in catalytic cycles, which is a highly interesting prospect for recyclable dye degradation systems.

  1. Applying fenton process in acrylic fiber wastewater treatment and practice teaching

    Science.gov (United States)

    Zhang, Chunhui; Jiang, Shan

    2018-02-01

    Acrylic fiber manufacturing wastewater, containing a wider range of pollutants, high concentration of refractory organics, poisonous and harmful matters, was significant to treat from the effluents of wastewater treatment plants (WWTPs). In this work, a Fenton reactor was employed for advanced treatment of the WWTP effluents. An orthogonal test and a parametric study were carried out to determine the effect of the main operating conditions and the Fenton process attain excellent performance on the degradation of pollutants under an optimal condition of ferrous dosage was 6.25 mM, hydrogen peroxide was 75 mM and initial pH value was 3.0 in 90 min reaction time. The removal efficiency of COD, TOC, NH4 +-N and TN reached from 45% to 69%. Lastly, as a teaching advice, the Fenton reactor was used in practicing teaching nicely.

  2. Surface treatment with Fenton for separation of acrylonitrile-butadiene-styrene and polyvinylchloride waste plastics by flotation.

    Science.gov (United States)

    Wang, Jian-Chao; Wang, Hui; Huang, Luo-Luo; Wang, Chong-Qing

    2017-09-01

    Surface treatment with Fenton was applied to flotation separation of acrylonitrile-butadienestyrene (ABS) and polyvinylchloride (PVC). After treatment, the floatability of ABS has a dramatic decrease, while the floatability of PVC is not affected. Fourier transform infrared spectroscopy (FT-IR) spectra and X-ray photoelectron spectroscopy (XPS) spectra were recorded to ascertain the mechanism of Fenton treatment. FT-IR and XPS analysis confirms that the introduction of oxygen-containing group occurs on the surface of ABS. The optimum conditions are molar ration (H 2 O 2 :Fe 2+ ) 10000, H 2 O 2 concentration 0.4M/L, pH 5.8, treatment time 2min and temperature 25°C, frother concentration 15mg/L and flotation time 3min. Particle sizes and mixing ratios were also investigated. Plastic mixtures of ABS and PVC with different particle sizes and mixing ratios can be effectively separated. The purity of ABS and PVC are up to 100% and 99.78%, respectively; the recovery of ABS and PVC are up to 99.89% and 100%, respectively. A practical, environmentally friendly and effective reagent, namely Fenton, was originally applied to surface treatment of ABS and PVC waste plastics for flotation separation of their mixtures. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Cu-modified alkalinized g-C3N4 as photocatalytically assisted heterogeneous Fenton-like catalyst

    Science.gov (United States)

    Dong, Qimei; Chen, Yingying; Wang, Lingli; Ai, Shasha; Ding, Hanming

    2017-12-01

    Alkalinized graphitic carbon nitride (CNK-OH) has been synthesized by one-step thermal poly-condensation method, and Cu-modified alkalinized g-C3N4 (Cu-CNK-OH) has been prepared by impregnation approach over CNK-OH. These copper species in Cu-CNK-OH are embedded in the frame of CNK-OH mostly via the Cu-N bonds. Cu-CNK-OH has been employed as a heterogeneous Fenton-like catalyst to degrade rhodamine B (RhB). Both the production efficiency of hydroxyl radicals and the transformation rate of Cu(II)/Cu(I) redox pair increase under visible-light irradiation. As a result, Cu-CNK-OH exhibits improved Fenton-like catalytic activity on the degradation of RhB. The synergetic interaction between Fenton-like process and photocatalytic process also contributes such improvement. The hydroxyl radicals and holes are the major reactive species in the photocatalytically assisted Fenton-like process. This study provides a valuable strategy for metal modification of alkalinized g-C3N4 with enhanced Fenton-like catalytic performance for the degradation of organic contaminants.

  4. MTP -493G/T gene polymorphism is associated with steatosis in hepatitis C-infected patients

    Energy Technology Data Exchange (ETDEWEB)

    Siqueira, E.R.F. [Departamento de Gastroenterologia, LIM-07, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP (Brazil); Departamento de Bioquímica, Faculdade de Medicina, Universidade de Pernambuco, Recife, PE (Brazil); Departamento de Gastroenterologia, Faculdade de Medicina, Universidade de Pernambuco, Recife, PE (Brazil); Oliveira, C.P.M.S. [Departamento de Gastroenterologia, LIM-07, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP (Brazil); Correa-Giannella, M.L. [Laboratório de Endocrinologia Celular e Molecular, LIM-25, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP (Brazil); Stefano, J.T. [Departamento de Gastroenterologia, LIM-07, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP (Brazil); Cavaleiro, A.M.; Fortes, M.A.H.Z. [Laboratório de Endocrinologia Celular e Molecular, LIM-25, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP (Brazil); Muniz, M.T.C.; Silva, F.S. [Departamento de Bioquímica, Faculdade de Medicina, Universidade de Pernambuco, Recife, PE (Brazil); Pereira, L.M.M.B. [Departamento de Gastroenterologia, Faculdade de Medicina, Universidade de Pernambuco, Recife, PE (Brazil); Instituto do Fígado de Pernambuco, Recife, PE (Brazil); Carrilho, F.J. [Departamento de Gastroenterologia, LIM-07, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP (Brazil)

    2011-12-09

    The reduction of hepatic microsomal transfer protein (MTP) activity results in fatty liver, worsening hepatic steatosis and fibrosis in chronic hepatitis C (CHC). The G allele of the MTP gene promoter, -493G/T, has been associated with lower transcriptional activity than the T allele. We investigated this association with metabolic and histological variables in patients with CHC. A total of 174 untreated patients with CHC were genotyped for MTP -493G/T by direct sequencing using PCR. All patients were negative for markers of Wilson's disease, hemochromatosis and autoimmune diseases and had current and past daily alcohol intake lower than 100 g/week. The sample distribution was in Hardy-Weinberg equilibrium. Among subjects with genotype 1, 56.8% of the patients with fibrosis grade 3+4 presented at least one G allele versus 34.3% of the patients with fibrosis grade 1+2 (OR = 1.8; 95%CI = 1.3-2.3). Logistic regression analysis with steatosis as the dependent variable identified genotypes GG+GT as independent protective factors against steatosis (OR = 0.4, 95%CI = 0.2-0.8; P = 0.01). The results suggest that the presence of the G allele of MTP -493G/T associated with lower hepatic MTP expression protects against steatosis in our CHC patients.

  5. MTP -493G/T gene polymorphism is associated with steatosis in hepatitis C-infected patients

    International Nuclear Information System (INIS)

    Siqueira, E.R.F.; Oliveira, C.P.M.S.; Correa-Giannella, M.L.; Stefano, J.T.; Cavaleiro, A.M.; Fortes, M.A.H.Z.; Muniz, M.T.C.; Silva, F.S.; Pereira, L.M.M.B.; Carrilho, F.J.

    2011-01-01

    The reduction of hepatic microsomal transfer protein (MTP) activity results in fatty liver, worsening hepatic steatosis and fibrosis in chronic hepatitis C (CHC). The G allele of the MTP gene promoter, -493G/T, has been associated with lower transcriptional activity than the T allele. We investigated this association with metabolic and histological variables in patients with CHC. A total of 174 untreated patients with CHC were genotyped for MTP -493G/T by direct sequencing using PCR. All patients were negative for markers of Wilson's disease, hemochromatosis and autoimmune diseases and had current and past daily alcohol intake lower than 100 g/week. The sample distribution was in Hardy-Weinberg equilibrium. Among subjects with genotype 1, 56.8% of the patients with fibrosis grade 3+4 presented at least one G allele versus 34.3% of the patients with fibrosis grade 1+2 (OR = 1.8; 95%CI = 1.3-2.3). Logistic regression analysis with steatosis as the dependent variable identified genotypes GG+GT as independent protective factors against steatosis (OR = 0.4, 95%CI = 0.2-0.8; P = 0.01). The results suggest that the presence of the G allele of MTP -493G/T associated with lower hepatic MTP expression protects against steatosis in our CHC patients

  6. Putative DNA-dependent RNA polymerase in Mitochondrial Plasmid of Paramecium caudatum Stock GT704

    Directory of Open Access Journals (Sweden)

    Trina Ekawati Tallei

    2015-10-01

    Full Text Available Mitochondria of Paramecium caudatum stock GT704 has a set of four kinds of linear plasmids with sizes of 8.2, 4.1, 2.8 and 1.4 kb. The plasmids of 8.2 and 2.8 kb exist as dimers consisting of 4.1- and 1.4-kb monomers, respectively. The plasmid 2.8 kb, designated as pGT704-2.8, contains an open reading frame encodes for putative DNA-dependent RNA polymerase (RNAP. This study reveals that this RNAP belongs to superfamily of DNA/RNA polymerase and family of T7/T3 single chain RNA polymerase and those of mitochondrial plasmid of fungi belonging to Basidiomycota and Ascomycota. It is suggested that RNAP of pGT704-2.8 can perform transcription without transcription factor as promoter recognition. Given that only two motifs were found, it could not be ascertained whether this RNAP has a full function independently or integrated with mtDNA in carrying out its function.

  7. Niobium substituted magnetite as a strong heterogeneous Fenton catalyst for wastewater treatment

    Energy Technology Data Exchange (ETDEWEB)

    Rahim Pouran, Shima, E-mail: rahimpooran@yahoo.com [Chemical Engineering Department, Faculty of Engineering, University of Malaya, 50603 Kuala Lumpur (Malaysia); Abdul Aziz, A.R., E-mail: azizraman@um.edu.my [Chemical Engineering Department, Faculty of Engineering, University of Malaya, 50603 Kuala Lumpur (Malaysia); Wan Daud, Wan Mohd Ashri, E-mail: ashri@um.edu.my [Chemical Engineering Department, Faculty of Engineering, University of Malaya, 50603 Kuala Lumpur (Malaysia); Embong, Zaidi, E-mail: zembong@gmail.com [Faculty of Science, Technology and Human Development, University Tun Hussein Onn Malaysia, 86400 Johor (Malaysia)

    2015-10-01

    Highlights: • A series of Nb substituted magnetite samples were prepared and characterized. • Samples had inverse spinel structure, good magnetic property, and durability. • Increased surface area resulted in higher adsorption capacity of the samples. • Nb incorporation enhanced degradation of methylene blue through Fenton reaction. • The activity of the catalysts increased by increment in Nb content of the samples. - Abstract: In this study, a series of Nb substituted magnetites; Fe{sub 3−x}Nb{sub x}O{sub 4} (x = 0.0, 0.022, 0.049, 0.099, and 0.19) were prepared and characterized by XRD, BET surface area, TEM, VSM, XPS, and chemical experiments. The magnetite inverse spinel structure and magnetic property were maintained in all the synthetized samples. A significant decrease in crystal size (≈two times) and increase in specific surface area (≈three times) were observed with increased Nb content, resulting in higher adsorption capacity of the samples. In addition, the reactivity of the synthetized samples was examined through degradation of methylene blue solution using Fenton-like reaction. It was found that the incorporation of niobium significantly improved the degradation of methylene blue of which total MB removal was achieved within 180 min at higher molar ratios of Nb (x = 0.19). This could be attributed to the generated oxygen vacancies on the surface of catalysts, the contribution of the introduced Nb cations in Fenton oxidation cycle for regeneration of Fe{sup 2+} cations, and increase in adsorption capacity of the samples due to larger surface area. The MB degradation through Fe{sub 2.79}Nb{sub 0.19}O{sub 4}/H{sub 2}O{sub 2} system was well described by the pseudo-first-order equation in kinetics. All samples showed good stability under the studied pH conditions. The amount of niobium leached was not detectable in neutral and basic solutions and the samples could be reused in oxidation process for several times without a significant

  8. A study on removal of elemental mercury in flue gas using fenton solution

    International Nuclear Information System (INIS)

    Liu, Yangxian; Wang, Yan; Wang, Qian; Pan, Jianfeng; Zhang, Yongchun; Zhou, Jianfei; Zhang, Jun

    2015-01-01

    Highlights: • A novel technique on oxidation of Hg 0 using Fenton was proposed. • The effects of several process parameters on Hg 0 removal were studied. • Products and ·OH in solution were detected. • Reaction mechanism of Hg 0 removal was studied. • Simultaneous removal of Hg 0 , NO and SO 2 was also studied. - Abstract: A novel technique on oxidation-separation of elemental mercury (Hg 0 ) in flue gas using Fenton solution in a bubbling reactor was proposed. The effects of several process parameters (H 2 O 2 concentration, Hg 0 inlet concentration, Fe 2+ concentration, solution temperature, solution pH, gas flow) and several flue gas components (NO, SO 2 , O 2 , CO 2 , inorganic ions and particulate matters on Hg 0 removal were studied. The results indicate that H 2 O 2 concentration, Fe 2+ concentration, solution pH and gas flow have great effects on Hg 0 removal. Solution temperature, Hg 0 , NO, SO 2 , CO 3 2− and HCO 3 − concentrations also have significant effects on Hg 0 removal. However, Cl − , SO 4 2− , NO 3 − , O 2 and CO 2 concentrations only have slight effects on Hg 0 removal. Furthermore, reaction mechanism of Hg 0 removal and simultaneous removal process of Hg 0 , NO and SO 2 were also studied. Hg 0 is removed by oxidation of ·OH and oxidation of H 2 O 2 . The simultaneous removal efficiencies of 100% for SO 2 , 100% for Hg 0 and 88.3% for NO were obtained under optimal test conditions. The results demonstrated the feasibility of Hg 0 removal and simultaneous removal of Hg 0 , SO 2 and NO using Fenton solution in a bubbling reactor

  9. Use of Enzymatic Bio-Fenton as a New Approach in Decolorization of Malachite Green

    Directory of Open Access Journals (Sweden)

    Afzal Karimi

    2012-01-01

    Full Text Available An enzymatic reaction using glucose oxidase was applied for in situ production of hydrogen peroxide for use in simultaneously Fenton's reaction in decolorization of malachite green. It was found that decolorization rate increased by increasing of glucose concentration from 0.2 g/L to 1.5 g/L. Decolorization rate showed different behaviors versus temperature changes. Initial rate of decolorization process was increased by increasing of temperature; after 30 minutes, especially at temperatures above 30°C, the decolorization rate was gradually reduced. The pH value in the reaction media was decreased from natural to about pH=3 which had synergic effect on the Fenton process by stabilizing of Fe2+ ions.

  10. DI-(2-ETHYLHEXYL PHTHALATE OXIDATIVE DEGRADATION BY FENTON PROCESS IN SYNTHETIC AND REAL PETROCHEMICAL WASTEWATER

    Directory of Open Access Journals (Sweden)

    R. Esmaeli

    2011-09-01

    Full Text Available Di-(2-Ethylhexyl phthalate (DEHP belongs to the class of phthalate esters and is used as an additive in many products including plastics, paints and inks or as a solvent in industrial formulations. The degradation of DEHP in aqueous solution using oxidative Fenton reaction (H2O2/Fe2+ was carried out in this study. It was found that H2O2 concentration, Fe2+ concentration, and pH were the three main factors that could significantly influence the degradation rates of DEHP. The highest degradation percentage (85.6 % of DEHP was observed within 60 min at pH 3 in H2O2/Fe2+ system. The results of our study suggested that the concentration with 90 mg/L H2O2, 5 mg/L Fe2+, and 20 mg/L DEHP in the solution at pH 3 were the optimal conditions. The optimized reaction parameters were preceded for treatment of real wastewater obtained from a petrochemical plant.

  11. Fenton treatment of bio-treated fermentation-based pharmaceutical wastewater: removal and conversion of organic pollutants as well as estimation of operational costs.

    Science.gov (United States)

    Cheng, Yunqin; Chen, Yunlu; Lu, Juncheng; Nie, Jianxin; Liu, Yan

    2018-04-01

    The Fenton process is used as a tertiary treatment to remove organic pollutants from the effluent of bio-treated pharmaceutical wastewater (EBPW). The optimal and most appropriate Fenton conditions were determined by an orthogonal array test and single-factor experiments. The removal of chemical oxygen demand (COD) was influenced by the following factors in a descending order: H 2 O 2 /Fe(II) molar ratio > H 2 O 2 dosage > reaction time. Under the most appropriate Fenton conditions (H 2 O 2 /Fe(II) molar ratio of 1:1, H 2 O 2 dosage of 120 mg L -1 and reaction time of 10 min), the COD and dissolved organic carbon (DOC) were removed with efficiencies of 62 and 53%, respectively, which met the national discharge standard (GB 21903-2008) for the Lake Tai Basin, China. However, the Fenton treatment was inadequate for removal of N compounds, and the removal of organic nitrogen led to an increment in N-NH 3 from 3.28 to 19.71 mg L -1 . Proteins and polysaccharides were completely removed, and humic acids (HAs) were partly removed with an efficiency of 55%. Three-dimensional excitation/emission matrix spectra (3DEEMs) indicated complete removal of fulvic acid-like substances and 90% reduction in the florescence intensity of humic acid-like substances. Organic pollutants with molecular weights (MW) > 10 kDa were completely removed, MW 5-10 kDa were degraded into smaller MW ones, and some low molecular weight acids (MW 0.1-1 kDa) were mineralized during the Fenton process. Some species, including pharmaceutical intermediates and solvents were detected by gas chromatography-mass spectrometry (GC-MS). The operational costs of the Fenton's treatment were estimated to be 0.58 yuan RMB/m 3 EBPW based on reagent usage and iron sludge treatment and disposal.

  12. Winery wastewater treatment by heterogeneous Photo-Fenton process and activated sludges; Depuracion de efluentes vinicolas ediante tratamientos Foto-Fenton en fase heterogenea y lodos activos

    Energy Technology Data Exchange (ETDEWEB)

    Mosteo, R.; Lalinde, N.; Ormad, Maria O. M.; Ovelleiro, J. L.

    2007-07-01

    The system composed by heterogeneous Photon-Fenton assisted by solar light and biological treatment based on activated sludge process treats adequately real winery wastewaters. the previous stage based on heterogeneous Photo-Fenton process produces a partial degradation of winery wastewaters and achieves a yield of degradation of organic matter (measured as TOC) close to 50%. The activated sludge process in simple stage doesn't present any operation problems (bulking phenomenon) and achieves a yield of degradation of organic matter of 90%. (Author) 16 refs.

  13. Effects of UV irradiation on humic acid removal by ozonation, Fenton and Fe0/air treatment: THMFP and biotoxicity evaluation

    International Nuclear Information System (INIS)

    Wei, Ming-Chi; Wang, Kai-sung; Hsiao, Tung-En; Lin, I.-Chen; Wu, Hui-Ju; Wu, Yuh-Luan; Liu, Pey-Horng; Chang, Shih-Hsien

    2011-01-01

    Highlights: → Fe 0 /air rapidly and effectively removed HA within 9 min and its COD, biotoxicity and THMFP were low. → THMFP of ozonation-treated solution was much higher than those of Fenton-treated and Fe 0 /air-treated solutions. → UV irradiation during ozonation and Fenton oxidation enhanced HA removal, but did not reduce the THMFP of the treated solutions. → Fe 0 /air treatment with UV irradiation obviously increased the THMFP of the treated solution. → The relationship between biotoxicity and chloroform in the chlorinated solution was insignificant. - Abstract: Effects of UV irradiation on humic acid (HA) removal by Fe 0 /air, ozonation and Fenton oxidation were investigated. The trihalomethane forming potential (THMFP) and toxicity of treated solutions were also evaluated. The experimental conditions were ozone of 21 mg min -1 , H 2 O 2 of 8 x 10 -4 M, Fe 0 of 20 g L -1 , air flow of 5 L min -1 , and UVC of 9 W. Results indicated that Fe 0 /air rapidly removed HA color (>99%) and COD (90%) within 9 min. 51-81% of color and 43-50% of COD were removed by ozonation and Fenton oxidation after 60 min. Both UV enhanced ozone and Fenton oxidation removed HA, but the Fe 0 /air process did not. Spectrum results showed all processes effectively diminished UV-vis spectra, except for ozonation. The THMFP of Fe 0 /air-treated solution (114 μg L -1 ) was much lower than those of Fenton- (226 μg L -1 ) and ozonation-treated solutions (499 μg L -1 ). Fe 0 /air with UV irradiation obviously increased the THMFP of treated solution (502 μg L -1 ). The toxicity results obtained from Vibrio fischeri light inhibition test indicated that the toxicity of Fe 0 /air-treated solution (5%) was much lower than that of ozonation- (33%) and Fenton-treated solutions (31%). Chlorination increased the solution toxicity. The correlation between biotoxicity and chloroform in the chlorinated solution was insignificant.

  14. Winery wastewater treatment by a combined process: long term aerated storage and Fenton's reagent.

    Science.gov (United States)

    Lucas, Marco S; Mouta, Maria; Pirra, António; Peres, José A

    2009-01-01

    The degradation of the organic pollutants present in winery wastewater was carried out by the combination of two successive steps: an aerobic biological process followed by a chemical oxidation process using Fenton's reagent. The main goal of this study was to evaluate the temporal characteristics of solids and chemical oxygen demand (COD) present in winery wastewater in a long term aerated storage bioreactor. The performance of different air dosage daily supplied to the biologic reactor, in laboratory and pilot scale, were examined. The long term hydraulic retention time, 11 weeks, contributed remarkably to the reduction of COD (about 90%) and the combination with the Fenton's reagent led to a high overall COD reduction that reached 99.5% when the mass ratio (R = H(2)O(2)/COD) used was equal to 2.5, maintaining constant the molar ratio H(2)O(2)/Fe(2+)=15.

  15. Photo oxidative degradation of azure-B by sono-photo-Fenton and photo-Fenton reagents

    Directory of Open Access Journals (Sweden)

    Prahlad Vaishnave

    2014-12-01

    Full Text Available A model for the decomposition of azure-B by photo-Fenton reagent in the presence of ultrasound in homogeneous aqueous solution has been described. The photochemical decomposition rate of azure-B is markedly increased in the presence of ultrasound. It is a rather inexpensive reagent for wastewater treatment. The effect of different variables like the concentration of ferric ion, concentration of dye, hydrogen peroxide, pH, light intensity etc. on the reaction rate has been observed. The progress of the sono-photochemical degradation was monitored spectrophotometrically. The optimum sono-photochemical degradation conditions were experimentally determined. The results showed that the dye was completely oxidized and degraded into CO2 and H2O. A suitable tentative mechanism for sono-photochemical bleaching of azure-B by sono-photo-Fenton’s reaction has been proposed.

  16. High Efficient Photo-Fenton Catalyst of α-Fe2O3/MoS2 Hierarchical Nanoheterostructures: Reutilization for Supercapacitors

    Science.gov (United States)

    Yang, Xijia; Sun, Haiming; Zhang, Lishu; Zhao, Lijun; Lian, Jianshe; Jiang, Qing

    2016-08-01

    A novel three-dimensional (3D) α-Fe2O3/MoS2 hierarchical nanoheterostructure is effectively synthesized via a facile hydrothermal method. The zero-dimensional (0D) Fe2O3 nanoparticles guide the growth of two-dimensional (2D) MoS2 nanosheets and formed 3D flower-like structures, while MoS2 facilitates the good dispersion of porous Fe2O3 with abundant oxygen vacancies. This charming 3D-structure with perfect match of non-equal dimension exhibits high recyclable photo-Fenton catalytic activity for Methyl orange pollutant and nice specific capacity in reusing as supercapacitor after catalysis. The synergistic effect between Fe2O3 and MoS2, the intermediate nanointerfaces, the 3D porous structures, and the abundant oxygen vacancies both contribute to highly active catalysis, nice electrochemical performance and stable cycling. This strategy is simple, cheap, and feasible for maximizing the value of the materials, as well as eliminating the secondary pollution.

  17. Study of the intensification of solar photo-Fenton degradation of carbamazepine with ferrioxalate complexes and ultrasound.

    Science.gov (United States)

    Expósito, A J; Monteagudo, J M; Durán, A; San Martín, I; González, L

    2018-01-15

    The intensification of the solar photo-Fenton system with ferrioxalate photoactive complexes and ultrasound applied to the mineralization of 15mg/L carbamazepine aqueous solution (CBZ) was evaluated. The experiments were carried out in a solar compound parabolic collector (CPC) pilot plant reactor coupled to an ultrasonic processor. The dynamic behavior of hydroxyl radicals generated under the different studied reaction systems was discussed. The initial concentrations of hydrogen peroxide and ferrous/oxalic acid and pH were found to be the most significant variables (32.79%, 25.98% and 26.04%, respectively). Under the selected optimal conditions ([H 2 O 2 ] 0 =150mg/L; [Fe 2+ ] 0 =2.5mg/L/[(COOH) 2 ] 0 =12.1mg/L; pH=5) CBZ was fully degraded after 5min and 80% of TOC was removed using a solar photo-Fenton system intensified with ferrioxalate (SPFF). However, no improvement in the mineralization using SPFF process combined with ultrasound was observed. More mild pH conditions could be used in the SPFF system if compared to the traditional photo-Fenton (pH 3) acidic systems. Finally, a possible reaction pathway for the mineralization of CBZ by the SPFF system was proposed and therein discussed. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Facile preparation of magnetic mesoporous Fe_3O_4/C/Cu composites as high performance Fenton-like catalysts

    International Nuclear Information System (INIS)

    Li, Keyan; Zhao, Yongqin; Janik, Michael J.; Song, Chunshan; Guo, Xinwen

    2017-01-01

    Highlights: • Fe-Cu composites with different compositions were prepared by calcining tartrates. • Magnetic mesoporous Fe_3O_4/C/Cu was obtained by calcining tartrate under N_2. • Fe_3O_4/C/Cu exhibits excellent photo-Fenton catalytic activity and reusability. • The activity is due to the synergistic and photo-reduction effects of Fe and Cu. - Abstract: Fe-Cu composites with different compositions and morphologies were synthesized by a hydrothermal method combined with precursor thermal transformation. γ-Fe_2O_3/CuO and α-Fe_2O_3/CuO were obtained by calcining the Fe and Cu tartrates under air atmosphere at 350 °C and 500 °C, respectively, while Fe_3O_4/C/Cu was obtained by calcining the tartrate precursor under N_2 atmosphere at 500 °C. The Fe_3O_4/C/Cu composite possessed mesoporous structure and large surface area up to 133 m"2 g"−"1. The Fenton catalytic performance of Fe_3O_4/C/Cu composite was closely related to the Fe/Cu molar ratio, and only proper amounts of Fe and Cu exhibited a synergistic enhancement in Fenton catalytic activity. Cu inclusion reduced Fe"3"+ to Fe"2"+, which accelerated the Fe"3"+/Fe"2"+ cycles and favored H_2O_2 decomposition to produce more hydroxyl radicals for methylene blue (MB) oxidation. Due to the photo-reduction of Fe"3"+ and Cu"2"+, the Fenton catalytic performance was greatly improved when amending with visible light irradiation in the Fe_3O_4/C/Cu-H_2O_2 system, and MB (100 mg L"−"1) was nearly removed within 60 min. The Fe_3O_4/C/Cu composite showed good recyclability and could be conveniently separated by an applied magnetic field. Compared with conventional methods for mesoporous composite construction, the thermolysis method using mixed metal tartrates as precursors has the advantages of easy preparation and low cost. This strategy provides a facile, cheap and green method for the synthesis of mesoporous composites as excellent Fenton-like catalysts, without any additional reductants or organic

  19. Electro-Fenton oxidation of reverse osmosis concentrate from sanitary landfill leachate: Evaluation of operational parameters.

    Science.gov (United States)

    Fernandes, Annabel; Labiadh, Lazhar; Ciríaco, Lurdes; Pacheco, Maria José; Gadri, Abdellatif; Ammar, Salah; Lopes, Ana

    2017-10-01

    The electro-Fenton oxidation of a concentrate from reverse osmosis of a sanitary landfill leachate, with an initial chemical oxygen demand (COD) of 42 g L -1 , was carried out using a carbon-felt cathode and a boron doped diamond anode. The influence of the applied current intensity, initial pH and dissolved iron initial concentration on the electro-Fenton process was assessed. For the experimental conditions used, results showed that the initial pH is the parameter that more strongly influences the current efficiency of the electro-Fenton process, being this influence more pronounced on the oxidation rate than on the mineralization rate of the organic matter. The increase in iron initial concentration was found to be detrimental, since the natural amount of iron present in the effluent, 73 mg L -1 of total iron and 61 mg L -1 of dissolved iron, was sufficient to ensure the electro-Fenton process at the applied intensities - 0.2-1.4 A. For the more favourable conditions studied, initial pH of 3 and natural iron concentration, it was found an increase in the organic load and nitrogen removals with the applied current intensity. For the highest current intensity applied, a COD removal of 16.7 g L -1 was achieved after 8-h experiments. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Simultaneous Transformation of Commingled Trichloroethylene, Tetrachloroethylene, and 1,4-Dioxane by a Microbially Driven Fenton Reaction in Batch Liquid Cultures

    Science.gov (United States)

    Sekar, Ramanan; Taillefert, Martial

    2016-01-01

    . Additional targets for ex situ and in situ degradation by the microbially driven Fenton reaction developed in the present study include multiple combinations of environmental contaminants susceptible to attack by Fenton reaction-generated HO˙ radicals, including commingled plumes of 1,4-dioxane, pentachlorophenol (PCP), PCE, TCE, 1,1,2-trichloroethane (TCA), and perfluoroalkylated substances (PFAS). PMID:27542932

  1. Extremely organic-rich coma of comet C/2010 G2 (Hill) during its outburst in 2012

    International Nuclear Information System (INIS)

    Kawakita, Hideyo; Kobayashi, Hitomi; Russo, Neil Dello; Vervack, Ron Jr.; Weaver, Harold A.; DiSanti, Mike A.; Opitom, Cyrielle; Jehin, Emmanuel; Manfroid, Jean; Gillon, Michael; Cochran, Anita L.; Harris, Walter M.; Bockelée-Morvan, Dominique; Biver, Nicolas; Crovisier, Jacques; McKay, Adam J.

    2014-01-01

    We performed high-dispersion near-infrared spectroscopic observations of comet C/2010 G2 (Hill) at 2.5 AU from the Sun using NIRSPEC (R ≈ 25,000) at the Keck II Telescope on UT 2012 January 9 and 10, about a week after an outburst had occurred. Over the two nights of our observations, prominent emission lines of CH 4 and C 2 H 6 , along with weaker emission lines of H 2 O, HCN, CH 3 OH, and CO were detected. The gas production rate of CO was comparable to that of H 2 O during the outburst. The mixing ratios of CO, HCN, CH 4 , C 2 H 6 , and CH 3 OH with respect to H 2 O were higher than those for normal comets by a factor of five or more. The enrichment of CO and CH 4 in comet Hill suggests that the sublimation of these hypervolatiles sustained the outburst of the comet. Some fraction of water in the inner coma might exist as icy grains that were likely ejected from nucleus by the sublimation of hypervolatiles. Mixing ratios of volatiles in comet Hill are indicative of the interstellar heritage without significant alteration in the solar nebula.

  2. Extremely organic-rich coma of comet C/2010 G2 (Hill) during its outburst in 2012

    Energy Technology Data Exchange (ETDEWEB)

    Kawakita, Hideyo; Kobayashi, Hitomi [Koyama Astronomical Observatory, Kyoto Sangyo University, Motoyama, Kamitamo, Kita, Kyoto 603-8555 (Japan); Russo, Neil Dello; Vervack, Ron Jr.; Weaver, Harold A. [The Johns Hopkins University Applied Physics Laboratory, Laurel, MD 20723-6099 (United States); DiSanti, Mike A. [Goddard Center for Astrobiology, NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States); Opitom, Cyrielle; Jehin, Emmanuel; Manfroid, Jean; Gillon, Michael [F. R. S.-FNRS, Institut d' Astrophysique et de Géophysique, Université de Liège, Allée du 6 août 17, B-4000 Liège (Belgium); Cochran, Anita L. [McDonald Observatory, 1 University Station C1402, Austin, TX 78712-0259 (United States); Harris, Walter M. [Department of Applied Sciences, University of California, One Shields Avenue, Davis, CA 95616 (United States); Bockelée-Morvan, Dominique; Biver, Nicolas; Crovisier, Jacques [LESIA, Observatoire de Paris, CNRS, UPMC, Université Paris-Diderot, 5 Place Jules Janssen, F-92195 Meudon (France); McKay, Adam J., E-mail: kawakthd@cc.kyoto-su.ac.jp [New Mexico State University, Las Cruces, NM 88001 (United States)

    2014-06-20

    We performed high-dispersion near-infrared spectroscopic observations of comet C/2010 G2 (Hill) at 2.5 AU from the Sun using NIRSPEC (R ≈ 25,000) at the Keck II Telescope on UT 2012 January 9 and 10, about a week after an outburst had occurred. Over the two nights of our observations, prominent emission lines of CH{sub 4} and C{sub 2}H{sub 6}, along with weaker emission lines of H{sub 2}O, HCN, CH{sub 3}OH, and CO were detected. The gas production rate of CO was comparable to that of H{sub 2}O during the outburst. The mixing ratios of CO, HCN, CH{sub 4}, C{sub 2}H{sub 6}, and CH{sub 3}OH with respect to H{sub 2}O were higher than those for normal comets by a factor of five or more. The enrichment of CO and CH{sub 4} in comet Hill suggests that the sublimation of these hypervolatiles sustained the outburst of the comet. Some fraction of water in the inner coma might exist as icy grains that were likely ejected from nucleus by the sublimation of hypervolatiles. Mixing ratios of volatiles in comet Hill are indicative of the interstellar heritage without significant alteration in the solar nebula.

  3. Solar photoelectro-Fenton degradation of the herbicide 4-chloro-2-methylphenoxyacetic acid optimized by response surface methodology

    International Nuclear Information System (INIS)

    Garcia-Segura, Sergi; Almeida, Lucio Cesar; Bocchi, Nerilso; Brillas, Enric

    2011-01-01

    Highlights: → The herbicide MCPA is quickly mineralized by solar photoelectro-Fenton. → A CCRD allowed the optimization of current, Fe 2+ content and solution pH. → TOC, MCE and energy consumption are described by response surface methodology. → Generated hydroxyl radical destroys MCPA and its aromatic oxidation by-products. → UV light of solar irradiation photolyzes the Fe(III)-carboxylate complexes produced. - Abstract: A central composite rotatable design and response surface methodology (RSM) were used to optimize the experimental variables of the solar photoelectro-Fenton (SPEF) treatment of the herbicide 4-chloro-2-methylphenoxyacetic acid (MCPA). The experiments were made with a flow plant containing a Pt/air-diffusion reactor coupled to a solar compound parabolic collector (CPC) under recirculation of 10 L of 186 mg L -1 MCPA solutions in 0.05 M Na 2 SO 4 at a liquid flow rate of 180 L h -1 with an average UV irradiation intensity of about 32 W m -2 . The optimum variables found for the SPEF process were 5.0 A, 1.0 mM Fe 2+ and pH 3.0 after 120 min of electrolysis. Under these conditions, 75% of mineralization with 71% of current efficiency and 87.7 kWh kg -1 TOC of energy consumption were obtained. MCPA decayed under the attack of generated hydroxyl radicals following a pseudo-first-order kinetics. Hydroxyl radicals also destroyed 4-chloro-2-methylphenol, methylhydroquinone and methyl-p-benzoquinone detected as aromatic by-products. Glycolic, maleic, fumaric, malic, succinic, tartronic, oxalic and formic acids were identified as generated carboxylic acids, which form Fe(III) complexes that are quickly photodecarboxylated by the UV irradiation of sunlight at the CPC photoreactor. A reaction sequence for the SPEF degradation of MCPA was proposed.

  4. USE OF FENTON'S REAGENT AS A DISINFECTANT

    Science.gov (United States)

    Combined sewage samples obtained from a wastewater treatment facility were disinfected by the Fenton's Reagent of several different compositions. The pre-settled samples contained both suspended solids (SS) and dissolved organic carbon (DOC) at concentrations of 28 and 290 mg/L,...

  5. Bio sorption of strontium from aqueous solution by the new strain of bacillus sp. strain GT-83

    International Nuclear Information System (INIS)

    Tajer Mohammad Ghazvini, P.; Ghorbanzadeh Mashkani, S.; Mazaheri, M.

    2009-01-01

    An attempt was made to isolate bacterial strains capable of removing strontium biologically. In this study ten different water samples collected from Neydasht spring in the north of Iran and then the bacterial species were isolated from the water samples. The initial screening of a total of 50 bacterial isolates resulted in selection of one strain.The isolated strain showed a maximum adsorption capacity with 55 milligrams strontium/g dry wt. It was tentatively identified as Bacillus sp. According to the morphological and biochemical properties, and called strain GT-83. Our studies indicated that Bacillus sp. GT-83 is able to grow aerobically in the presence of 50 mM SrCl 2 , but its growth was inhibited at high levels of strontium concentrations. The bio sorption capacity of Bacillus sp. GT-83 depends strongly on the p H solution. Hence the maximum strontium sorption capacity of Bacillus sp. GT-83 was obtained at pah 10, independent of absence or presence of MgCl 2 of different concentrations. Strontium-salt bio sorption studies were also performed at this p H values. The equilibrium bio sorption of strontium was elevated by increasing the strontium concentration, up to 250 milligrams/l for Bacillus sp. GT-83. The maximum bio sorption of strontium was obtained at temperatures in the range of 30-35 d eg C . The Bacillus sp. GT-83 bio sorbed 97 milligrams strontium/g dry wt at 100 milligrams/l initial strontium concentration without MgCl 2 . When MgCl 2 concentration increased to 15%(w/v), these values dropped to 23.6 milligrams strontium/g dry wt at the same conditions. Uptake of strontium within 5 min of incubation was relatively rapid and the absorption continued slowly thereafter

  6. Remediation of polluted soils contaminated with Linear Alkyl Benzenes using Fenton's reagent

    Directory of Open Access Journals (Sweden)

    Douglas do Nascimento Silva

    2005-06-01

    Full Text Available Linear Alkyl Benzenes (LABs are used as insulating oil for electric cables. When it happens a spill, LABs they are basically sorbed in the soil, because, these compounds have high hidrophobicity and low vapor pressure. The conventional methods of treatment of soils are not efficient. The Fenton's reaction (reaction between a solution of iron II and hydrogen peroxide it generates hydroxyl radicals, not selective, and capable of oxidize a great variety of organic compounds. A study was conducted to evaluate the viability of use of the Fenton's reagents to promote the remediation of polluted soils with Linear Alkyl Benzenes. A column was especially projected for these experiments, packed with a sandy and other soil loamy. The pH of the soil was not altered. The obtained results demonstrated the technical viability of the process of injection of the Fenton's reagents for the treatment of polluted areas with LABs.Os Linear Alquilbenzenos (LABs são usados como fluido refrigerante de cabos elétricos. Quando ocorre um vazamento, os LABs ficam basicamente adsorvidos no solo, pois, são compostos bastante hidrofóbicos e com baixa pressão de vapor. Os métodos convencionais de tratamento de solos não são eficientes. A reação de Fenton (solução de ferro II e peróxido de hidrogênio gera radicais hidroxila, não seletivos, e capazes de oxidar uma grande variedade de compostos orgânicos, chegando a mineralização dos mesmos. Neste trabalho foi estudada a viabilidade de utilização dos reagentes de Fenton para promover a remediação de solos contaminados com LABs. Utilizou-se uma coluna especialmente projetada para estes experimentos, empacotada com um solo arenoso e outro argiloso. O pH do solo não foi alterado. Os resultados obtidos demonstram a viabilidade técnica do processo de injeção dos reagentes de Fenton para o tratamento de áreas contaminadas com LABs.

  7. Simple preparation of Fenton catalyst@bacterial cellulose for waste water treatment

    Science.gov (United States)

    Wibowo, Arie; Febi Indrawan, Radian; Triadhi, Untung; Hasdi Aimon, Akfiny; Iskandar, Ferry; Ardy, Husaini

    2018-02-01

    Heterogeneous fenton catalyst is one of the attractive technologies for destruction of persistent and non-biodegradable pollutant in wastewater, because it can be used in wide range of pH and recyclable. Herein, commercial bacterial celluloses (BCs) were used as an alternative support of fenton catalyst to improve their catalytic activity. Scanning Electron Microscope (SEM) observations indicated that the presence of BCs and decreasing precursor concentration might promote formation of smaller particle sizes of catalyst from 3.5 μm of bare catalyst to 0.7 μm of catalyst@BC. UV-vis measurement showed that fast degradation of dyes with half-time degradation at around 25 min was observed in sample using catalyst@BCs with precursor concentration of 0.01 M. Successful preparation of heterogeneous fenton catalyst with smaller particle size and better catalytic activity is important for their application in wastewater treatment.

  8. Application of photo-fenton as a tertiary treatment of emerging contaminants in municipal wastewater.

    Science.gov (United States)

    Klamerth, N; Malato, S; Maldonado, M I; Agüera, A; Fernández-Alba, A R

    2010-03-01

    This work focuses on the treatment of real effluents from a municipal wastewater treatment plant (RE) with solar photo-Fenton (5 mg and 20 mg L(-1) Fe, pH approximately 3 and 50 mg L(-1) initial H(2)O(2) concentration) at pilot plant scale. In some experiments RE was spiked with 15 different (acetaminophen, antipyrine, atrazine, caffeine, carbamazepine, diclofenac, flumequine, hydroxybiphenyl, ibuprofen, isoproturon, ketorolac, ofloxacin, progesterone, sulfamethoxazole, and triclosan) emerging contaminants (ECs) at 100 and 5 microg L(-1) each which were added directly into RE prior to treatment. All experiments showed successful degradation of ECs in real effluents from different municipal wastewater treatment plants at low iron concentration (5 mg L(-1)). Although the most degradation took place during the Fenton process, photo-Fenton was necessary to degrade all ECs below their limit of detection (LOD). In the case of the RE containing 52 ECs (determined by HPLC-QTRAP-MS), four of them could not be degraded to their LOD and were still present, although at extremely low concentrations (nicotine 47 ng L(-1), cotinine 11 ng L(-1), chlorfenvinphos 99 ng L(-1), and caffeine 8 ng L(-1)). ECs were easily degraded by (*)OH without substantial competition with the organic content of the RE.

  9. Modified natural zeolite as heterogeneous Fenton catalyst in treatment of recalcitrants in industrial effluent

    Directory of Open Access Journals (Sweden)

    Milton M. Arimi

    2017-04-01

    Full Text Available Industrial effluents with high recalcitrants should undergo post-treatment after biological treatment. The aim of this study was to use cheap and abundantly available natural materials to develop heterogeneous Fenton catalysts for the removal of colored recalcitrants in molasses distillery wastewater (MDW. The pellets of zeolite, which is naturally available in many countries, were modified by pre-treatment with sulphuric acid, nitric acid and hydrochloric acid, before embedding on them the ferrous ions. The effects of pH and temperature on heterogeneous Fenton were studied using the modified catalysts. The sulphuric acid-ferrous modified catalysts showed the highest affectivity which achieved 90% color and 60% TOC (total organic carbon removal at 150 g/L pellet catalyst dosage, 2 g/L H2O2 and 25 °C. The heterogeneous Fenton with the same catalyst caused improvement in the biodegradability of anaerobic effluent from 0.07 to 0.55. The catalyst was also applied to pre-treat the raw MDW and increased it's biodegradability by 4%. The color of the resultant anaerobic effluent was also reduced. The kinetics of total TOC removal was found to depend on operation temperature. It was best described by simultaneous first and second order kinetics model for the initial reaction and second order model for the rest of the reaction.

  10. Decontamination of unsymmetrical dimethylhydrazine waste water by hydrodynamic cavitation-induced advanced Fenton process.

    Science.gov (United States)

    Torabi Angaji, Mahmood; Ghiaee, Reza

    2015-03-01

    A pilot scale hydrodynamic cavitation (HC) reactor, using iron metal blades, as the heterogeneous catalyst, with no external source of H₂O₂ was developed for catalytic decontamination of unsymmetrical dimethylhydrazine (UDMH) waste water. In situ generation of Fenton reagents suggested an induced advanced Fenton process (IAFP) to explain the enhancing effect of the used catalyst in the HC process. The effects of the applied catalyst, pH of the initial solution (1.0-9.7), initial UDMH concentration (2-15 mg/l), inlet pressure (5.5-7.8bar), and downstream pressure (2-6 bar), have been investigated. The results showed that the highest cavitation yield can be obtained at pH 3 and initial UDMH concentration of 10mg/l. Also, an increase in the inlet pressure would lead to an increase in the extent of UDMH degradation. In addition, the optimum value of 3 bar was determined for the downstream pressure that resulted to 98.6% degradation of UDMH after 120 min of processing time. Neither n-nitrosodimethylamine (NDMA) nor any other toxic byproduct (/end-product) was observed in the investigated samples. Formic acid and acetic acid, as well as nitromethane, were identified as oxidation by-products. The present work has conclusively established that hydrodynamic cavitation in combination with Fenton's chemistry can be effectively used for the degradation of UDMH. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Selective tumor cell death induced by irradiated riboflavin through recognizing DNA G-T mismatch.

    Science.gov (United States)

    Yuan, Yi; Zhao, Yongyun; Chen, Lianqi; Wu, Jiasi; Chen, Gangyi; Li, Sheng; Zou, Jiawei; Chen, Rong; Wang, Jian; Jiang, Fan; Tang, Zhuo

    2017-09-06

    Riboflavin (vitamin B2) has been thought to be a promising antitumoral agent in photodynamic therapy, though the further application of the method was limited by the unclear molecular mechanism. Our work reveals that riboflavin was able to recognize G-T mismatch specifically and induce single-strand breaks in duplex DNA targets efficiently under irradiation. In the presence of riboflavin, the photo-irradiation could induce the death of tumor cells that are defective in mismatch repair system selectively, highlighting the G-T mismatch as potential drug target for tumor cells. Moreover, riboflavin is a promising leading compound for further drug design due to its inherent specific recognition of the G-T mismatch. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.

  12. Oxidative Degradation of Phenol containing Wastewater using Fenton Reagent, Permanganate and Ultraviolet Radiation

    International Nuclear Information System (INIS)

    Abd El-Rahman, N.M.; Talaat, H.A.; Sorour, M.H.

    1999-01-01

    Phenol containing wastewaters are generated by numerous industrial units including integrated steel mills, textile mills, plastic production, etc. The present work is targeted to explore the viable oxidation techniques for degradation of phenolic wastewater. Three modes of treatment have been adopted in this study, namely, sole oxidant mode using Fenton reagent or permanganate, UV-assisted oxidation and two consequent chemical oxidation steps. Results indicated the superiority of fenton reagent over KMnO 4 oxidation in the sole oxidant mode. On the other hand, UV-assisted KMnO 4 oxidation enables almost complete COD reduction. Dual chemical oxidation mode employing KMnO 4 oxidation followed by Fenton reagent is also an efficient oxidative degradation system

  13. Comparison of Fenton process and adsorption method for treatment of industrial container and drum cleaning industry wastewater.

    Science.gov (United States)

    Güneş, Elçin; Çifçi, Deniz İzlen; Çelik, Suna Özden

    2018-04-01

    The present study aims to explore the characterization of industrial container and drum cleaning (ICDC) industry wastewater and treatment alternatives of this wastewater using Fenton and adsorption processes. Wastewater derived from ICDC industry is usually treated by chemical coagulation and biological treatment in Turkey and then discharged in a centralized wastewater treatment facility. It is required that the wastewater COD is below 1500 mg/L to treat in a centralized wastewater treatment facility. The wastewater samples were characterized for parameters of pH, conductivity, COD, BOD 5 , TSS, NH 3 -N, TN, TOC, TP, Cd, Cr, Cu, Fe, Ni, Pb, Zn, and Hg. Initial COD values were in the range of 11,300-14,200 mg/L. The optimum conditions for Fenton treatment were 35-40 g/L for H 2 O 2 , 2-5 g/L for Fe 2+ , and 13-36 for H 2 O 2 /Fe 2+ molar ratio. The optimum conditions of PAC doses and contact times in adsorption studies were 20-30 g/L and 5-12 h, respectively. Removal efficiencies of characterized parameters for the three samples were compared for both Fenton and adsorption processes under optimum conditions. The results suggest that these wastewaters are suitable for discharge to a centralized wastewater treatment plant.

  14. Simultaneous decomplexation in blended Cu(II)/Ni(II)-EDTA systems by electro-Fenton process using iron sacrificing electrodes.

    Science.gov (United States)

    Zhao, Zilong; Dong, Wenyi; Wang, Hongjie; Chen, Guanhan; Tang, Junyi; Wu, Yang

    2018-05-15

    This research explored the application of electro-Fenton (E-Fenton) technique for the simultaneous decomplexation in blended Cu(II)/Ni(II)-EDTA systems by using iron sacrificing electrodes. Standard discharge (0.3 mg L -1 for Cu and 0.1 mg L -1 for Ni in China) could be achieved after 30 min reaction under the optimum conditions (i.e. initial solution pH of 2.0, H 2 O 2 dosage of 6 mL L -1  h -1 , current density of 20 mA/cm 2 , inter-electrode distance of 2 cm, and sulfate electrolyte concentration of 2000 mg L -1 ). The distinct differences in apparent kinetic rate constants (k app ) and intermediate removal efficiencies corresponding to mere and blended systems indicated the mutual promotion effect toward the decomplexation between Cu(II) and Ni(II). Massive accumulation of Fe(Ⅲ) favored the further removal of Cu(II) and Ni(II) by metal ion substitution. Species distribution results demonstrated that the decomplexation of metal-EDTA in E-Fenton process was mainly contributed to the combination of various reactions, including Fenton reaction together with the anodic oxidation, electro-coagulation (E-coagulation) and electrodeposition. Unlike hypophosphite and citrate, the presence of chlorine ion displayed favorable effects on the removal efficiencies of Cu(II) and Ni(II) at low dosage, but facilitated the ammonia nitrogen (NH 4 + -N) removal only at high dosage. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Tratamento de lixiviados de aterros de resíduos sólidos utilizando Processos Fenton e Foto-Fenton Solar

    Directory of Open Access Journals (Sweden)

    Fábio Moraes da Costa

    2015-01-01

    Full Text Available O lixiviado de aterros de resíduos sólidos urbanos é uma complexa mistura de substâncias orgânicas e inorgânicas, que em sua composição causam danos ao meio ambiente, devido à elevada concentração de matéria orgânica recalcitrante e à toxicidade presente. A proposta deste trabalho envolve a aplicação dos processos oxidativos avançados (POA, como tratamento de lixiviado oriundos de dois aterros sanitários, Gericinó (Rio de Janeiro/RJ e Gramacho (Duque de Caxias/RJ, dois aterros com mais de 30 anos de operação, sendo que o último encontra-se encerrado há 2 anos. O objetivo da utilização dos POA é melhorar a qualidade do lixiviado para um tratamento biológico subsequente, para isso foi utilizado o ensaio com a bactéria Aliivibrio fischeri para avaliação da toxicidade. Para o Processo Fenton-escuro, realizado em escala de bancada, nos experimentos realizados a pH=3,0 e razão Fe+2:H2O2 igual a 1:5 foram obtidas remoções de 56% e 19% de DQO para os lixiviados oriundos de Gericinó e Gramacho, respectivamente. Para o Processo Foto-Fenton Solar, realizado em uma planta piloto, nos testes a pH=3,0 e razão Fe+2:H2O2 igual a 1:5, foram alcançadas 88% e 78% de remoção de DQO. Essas condições permitiram uma diminuição da toxicidade dos lixiviados pa ra valores de coeficiente de efeito igual a 50% (CE 50% para Aliivibrio fischeri maior que 50%, indicando um lixiviado mais adequado para tratamento biológico posterior.

  16. Decolorization of Diazo Dye Ponceau S by Fenton Process

    Directory of Open Access Journals (Sweden)

    Muhammad Muslim

    2013-12-01

    Full Text Available An attempt has been taken to decolorize and mineralize Ponceau S (PS, a diazo dye, in aqueous solution by Fenton process. Effects of solution pH, concentrations of H2O2, Fe(II and PS on the decolorization of PS have also been studied through batch experiments. About 90% decolorization was found under the optimal conditions [PS]: [H2O2]: [Fe(II] = 1:12:2 and [H2O2]/[Fe(II] = 6 at pH 2.85 in 40 minutes. The overall results revealed that mineralization was rather slower as compared with the decolorization.

  17. Enhancement of Fenton oxidation for removing organic matter from hypersaline solution by accelerating ferric system with hydroxylamine hydrochloride and benzoquinone.

    Science.gov (United States)

    Peng, Siwei; Zhang, Weijun; He, Jie; Yang, Xiaofang; Wang, Dongsheng; Zeng, Guisheng

    2016-03-01

    Fenton oxidation is generally inhibited in the presence of a high concentration of chloride ions. This study investigated the feasibility of using benzoquinone (BQ) and hydroxylamine hydrochloride (HA) as Fenton enhancers for the removal of glycerin from saline water under ambient temperature by accelerating the ferric system. It was found that organics removal was not obviously affected by chloride ions of low concentration (less than 0.1mol/L), while the mineralization rate was strongly inhibited in the presence of a large amount of chloride ions. In addition, ferric hydrolysis-precipitation was significantly alleviated in the presence of HA and BQ, and HA was more effective in reducing ferric ions into ferrous ions than HA, while the H2O2 decomposition rate was higher in the BQ-Fenton system. Electron spin resonance analysis revealed that OH production was reduced in high salinity conditions, while it was enhanced after the addition of HA and BQ (especially HA). This study provided a possible solution to control and alleviate the inhibitory effect of chloride ions on the Fenton process for organics removal. Copyright © 2015. Published by Elsevier B.V.

  18. Fenton-like Degradation of MTBE: Effects of Iron Counter Anion and Radical Scavengers

    Science.gov (United States)

    Fenton-driven oxidation of Methyl tert-butyl ether (MTBE) (0.11-0.16 mM) in batch reactors containing ferric iron (5 mM), hydrogen peroxide (H2O2) (6 mM) (pH=3) was performed to investigate MTBE transformation mechanisms. Independent variables included the form of iron (Fe) (Fe2(...

  19. Newtonian and pseudo-Newtonian Hill problem

    International Nuclear Information System (INIS)

    Steklain, A.F.; Letelier, P.S.

    2006-01-01

    A pseudo-Newtonian Hill problem based on the Paczynski-Wiita pseudo-Newtonian potential that reproduces general relativistic effects is presented and compared with the usual Newtonian Hill problem. Poincare maps, Lyapunov exponents and fractal escape techniques are employed to study bounded and unbounded orbits. In particular we consider the systems composed by Sun, Earth and Moon and composed by the Milky Way, the M2 cluster and a star. We find that some pseudo-Newtonian systems-including the M2 system-are more stable than their Newtonian equivalent

  20. Citric acid-modified Fenton's reaction for the oxidation of chlorinated ethylenes in soil solution systems.

    Science.gov (United States)

    Seol, Yongkoo; Javandel, Iraj

    2008-06-01

    Fenton's reagent, a solution of hydrogen peroxide and ferrous iron catalyst, is used for an in situ chemical oxidation of organic contaminants. Sulfuric acid is commonly used to create an acidic condition needed for catalytic oxidation. Fenton's reaction often involves pressure buildup and precipitation of reaction products, which can cause safety hazards and diminish efficiency. We selected citric acid, a food-grade substance, as an acidifying agent to evaluate its efficiencies for organic contaminant removal in Fenton's reaction, and examined the impacts of using citric acid on the unwanted reaction products. A series of batch and column experiments were performed with varying H2O2 concentrations to decompose selected chlorinated ethylenes. Either dissolved iron from soil or iron sulfate salt was added to provide the iron catalyst in the batch tests. Batch experiments revealed that both citric and sulfuric acid systems achieved over 90% contaminant removal rates, and the presence of iron catalyst was essential for effective decontamination. Batch tests with citric acid showed no signs of pressure accumulation and solid precipitations, however the results suggested that an excessive usage of H2O2 relative to iron catalysts (Fe2+/H2O2<1/330) would result in lowering the efficiency of contaminant removal by iron chelation in the citric acid system. Column tests confirmed that citric acid could provide suitable acidic conditions to achieve higher than 55% contaminant removal rates.

  1. Hume, Mill, Hill, and the sui generis epidemiologic approach to causal inference.

    Science.gov (United States)

    Morabia, Alfredo

    2013-11-15

    The epidemiologic approach to causal inference (i.e., Hill's viewpoints) consists of evaluating potential causes from the following 2, noncumulative angles: 1) established results from comparative, observational, or experimental epidemiologic studies; and 2) reviews of nonepidemiologic evidence. It does not involve statements of statistical significance. The philosophical roots of Hill's viewpoints are unknown. Superficially, they seem to descend from the ideas of Hume and Mill. Hill's viewpoints, however, use a different kind of evidence and have different purposes than do Hume's rules or Mill's system of logic. In a nutshell, Hume ignores comparative evidence central to Hill's viewpoints. Mill's logic disqualifies as invalid nonexperimental evidence, which forms the bulk of epidemiologic findings reviewed from Hill's viewpoints. The approaches by Hume and Mill cannot corroborate successful implementations of Hill's viewpoints. Besides Hume and Mill, the epidemiologic literature is clueless about a plausible, pre-1965 philosophical origin of Hill's viewpoints. Thus, Hill's viewpoints may be philosophically novel, sui generis, still waiting to be validated and justified.

  2. Facile hydrothermal synthesis of Fe3O4@cellulose aerogel nanocomposite and its application in Fenton-like degradation of Rhodamine B.

    Science.gov (United States)

    Jiao, Yue; Wan, Caichao; Bao, Wenhui; Gao, He; Liang, Daxin; Li, Jian

    2018-06-01

    A magnetic cellulose aerogel-supported Fe 3 O 4 nanoparticles composite was designed as a highly efficient and eco-friendly catalyst for Fenton-like degradation of Rhodamine B (RhB). The composite (coded as Fe 3 O 4 @CA) was formed by embedding well-dispersed Fe 3 O 4 nanoparticles into the 3D structure of cellulose aerogels by virtue of a facile and cheap hydrothermal method. Comparative studies indicate that the RhB decolorization ratio is much higher in co-presence of Fe 3 O 4 and H 2 O 2 than that in presence of Fe 3 O 4 or H 2 O 2 only, revealing that the Fe 3 O 4 @CA-catalyzed Fenton-like reaction governed the RhB decolorization process. It was also found that almost 100% RhB removal was achieved in the Fenton-like system. Moreover, the composite exhibited higher catalytic activity than that of the individual Fe 3 O 4 particles. In addition, the Fe 3 O 4 @CA catalyst retained ∼97% of its ability to degrade RhB after the six successive degradation experiments, suggesting its excellent reusability. All these merits indicate that the green and low-cost catalyst with strong magnetic responsiveness possesses good potential for H 2 O 2 -driven Fenton-like treatment of organic dyestuff wastewater. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Role of copper pyrovanadate as heterogeneous photo-Fenton like catalyst for the degradation of neutral red and azure-B: An eco-friendly approach

    Energy Technology Data Exchange (ETDEWEB)

    Kalal, Sangeeta; Ameta, Noopur; Kumar, Sudhish; Punjabi, Pinki Bala [M. L. Sukhadia University, Udaipur (India); Chauhan, Narendra Pal Singh [B. N. P. G. College, Udaipur (India); Ameta, Rakshit [PAHER University, Udaipur (India)

    2014-12-15

    The heterogeneous photo-Fenton like process is a green chemical pathway.. It has an edge over conventional Fenton and photo-Fenton processes as it does not require the removal of ferrous/ferric ions in the form of sludge. We prepared copper pyrovanadate or Volborthite (Cu{sub 3}V{sub 2}(OH){sub 2}O{sub 7}·2H{sub 2}O) composite photocatalyst by wet chemical method. The photocatalyst was characterized by SEM, XRD, IR, TGA/DSC, EDX and BET. Experiments demonstrated that catalyst could effectively catalyze degradation of neutral red and azure-B in presence of H{sub 2}O{sub 2} in visible light. Moreover, the photo-Fenton-like catalytic activity of Cu{sub 3}V{sub 2}(OH){sub 2}O{sub 7}·2H{sub 2}O was much higher than CuO and V{sub 2}O{sub 5}, when used alone as photocatalyst. The effect of variation of different parameters, i.e., pH, amount of photocatalyst, concentration of dye, amount of H{sub 2}O{sub 2} and light intensity was also investigated. The degradation was well fitted under pseudo-first-order reaction with a rate constant of 2.081x10{sup −4} sec{sup −1} and 3.876x10{sup −4} sec{sup −1} for neutral red and azure-B, respectively. Quality parameters of dye solutions before and after photo-Fenton degradation were also determined. A tentative mechanism involving •OH radical as an oxidant has been proposed. The high catalytic activity may be due to the Cu{sub 3}V{sub 2}(OH){sub 2}O{sub 7}·2H{sub 2}O shell, which not only increased the surface hydroxyl groups, but also enhanced the interfacial electron transfer.. The catalyst has been found to possess good recyclability.

  4. Role of copper pyrovanadate as heterogeneous photo-Fenton like catalyst for the degradation of neutral red and azure-B: An eco-friendly approach

    International Nuclear Information System (INIS)

    Kalal, Sangeeta; Ameta, Noopur; Kumar, Sudhish; Punjabi, Pinki Bala; Chauhan, Narendra Pal Singh; Ameta, Rakshit

    2014-01-01

    The heterogeneous photo-Fenton like process is a green chemical pathway.. It has an edge over conventional Fenton and photo-Fenton processes as it does not require the removal of ferrous/ferric ions in the form of sludge. We prepared copper pyrovanadate or Volborthite (Cu_3V_2(OH)_2O_7·2H_2O) composite photocatalyst by wet chemical method. The photocatalyst was characterized by SEM, XRD, IR, TGA/DSC, EDX and BET. Experiments demonstrated that catalyst could effectively catalyze degradation of neutral red and azure-B in presence of H_2O_2 in visible light. Moreover, the photo-Fenton-like catalytic activity of Cu_3V_2(OH)_2O_7·2H_2O was much higher than CuO and V_2O_5, when used alone as photocatalyst. The effect of variation of different parameters, i.e., pH, amount of photocatalyst, concentration of dye, amount of H_2O_2 and light intensity was also investigated. The degradation was well fitted under pseudo-first-order reaction with a rate constant of 2.081x10"−"4 sec"−"1 and 3.876x10"−"4 sec"−"1 for neutral red and azure-B, respectively. Quality parameters of dye solutions before and after photo-Fenton degradation were also determined. A tentative mechanism involving •OH radical as an oxidant has been proposed. The high catalytic activity may be due to the Cu_3V_2(OH)_2O_7·2H_2O shell, which not only increased the surface hydroxyl groups, but also enhanced the interfacial electron transfer.. The catalyst has been found to possess good recyclability

  5. Iron oxide-mediated semiconductor photocatalysis vs. heterogeneous photo-Fenton treatment of viruses in wastewater. Impact of the oxide particle size.

    Science.gov (United States)

    Giannakis, Stefanos; Liu, Siting; Carratalà, Anna; Rtimi, Sami; Talebi Amiri, Masoud; Bensimon, Michaël; Pulgarin, César

    2017-10-05

    The photo-Fenton process is recognized as a promising technique towards microorganism disinfection in wastewater, but its efficiency is hampered at near-neutral pH operating values. In this work, we overcome these obstacles by using the heterogeneous photo-Fenton process as the default disinfecting technique, targeting MS2 coliphage in wastewater. The use of low concentrations of iron oxides in wastewater without H 2 O 2 (wüstite, maghemite, magnetite) has demonstrated limited semiconductor-mediated MS2 inactivation. Changing the operational pH and the size of the oxide particles indicated that the isoelectric point of the iron oxides and the active surface area are crucial in the success of the process, and the possible underlying mechanisms are investigated. Furthermore, the addition of low amounts of Fe-oxides (1mgL -1 ) and H 2 O 2 in the system (1, 5 and 10mgL -1 ) greatly enhanced the inactivation process, leading to heterogeneous photo-Fenton processes on the surface of the magnetically separable oxides used. Additionally, photo-dissolution of iron in the bulk, lead to homogeneous photo-Fenton, further aided by the complexation by the dissolved organic matter in the solution. Finally, we assess the impact of the presence of the bacterial host and the difference caused by the different iron sources (salts, oxides) and the Fe-oxide size (normal, nano-sized). Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Immobilizing LaFeO_3 nanoparticles on carbon spheres for enhanced heterogeneous photo-Fenton like performance

    International Nuclear Information System (INIS)

    Wang, Kaixuan; Niu, Helin; Chen, Jingshuai; Song, Jiming; Mao, Changjie; Zhang, Shengyi; Gao, Yuanhao

    2017-01-01

    Highlights: • LaFeO_3 nanoparticles sub–10 nm were successfully immobilized on monodisperse carbon spheres for the first time through a facile and environmental friendly ultrasonic assisted surface ions adsorption method. • LaFeO_3/C nanocomposite exhibits much higher photo-Fenton like catalytic activity than LaFeO_3. • The superior property was attributed to the synergistic effects from the photo-Fenton like process and the presence of monodisperse carbon spheres. - Abstract: LaFeO_3 nanoparticles immobilized on the surface of monodisperse carbon spheres have been obtained through a facile and environmentally friendly ultrasonic assisted surface ions adsorption method. The LaFeO_3/C nanocomposite was evaluated as photo-Fenton like catalyst for the degradation of Rhodamine B (RhB) under visible light irradiation (λ > 420 nm). The LaFeO_3/C nanocomposite possesses high specific surface area compared with pure LaFeO_3 and significantly enhanced photo-Fenton like catalytic performance. The possible formation process of the LaFeO_3/C nanocomposite and the mechanism for photo-Fenton like reaction were discussed. The superior property was attributed to the synergistic effects from the photo-Fenton like process and the presence of carbon spheres. In addition, the heterogeneous process led to better recyclability of this type of catalyst.

  7. Hill's formula

    Energy Technology Data Exchange (ETDEWEB)

    Bolotin, Sergey V [Steklov Mathematical Institute, Russian Academy of Sciences, Moscow (Russian Federation); Treschev, Dmitrii V [M. V. Lomonosov Moscow State University, Moscow (Russian Federation)

    2010-07-27

    In his study of periodic orbits of the three-body problem, Hill obtained a formula connecting the characteristic polynomial of the monodromy matrix of a periodic orbit with the infinite determinant of the Hessian of the action functional. A mathematically rigorous definition of the Hill determinant and a proof of Hill's formula were obtained later by Poincare. Here two multidimensional generalizations of Hill's formula are given: for discrete Lagrangian systems (symplectic twist maps) and for continuous Lagrangian systems. Additional aspects appearing in the presence of symmetries or reversibility are discussed. Also studied is the change of the Morse index of a periodic trajectory upon reduction of order in a system with symmetries. Applications are given to the problem of stability of periodic orbits. Bibliography: 34 titles.

  8. The Origin of the Columbia Hills

    Science.gov (United States)

    Rice, J. W.

    2005-12-01

    The Columbia Hills form a rugged ridge complex comprised of 7 peaks spanning some 3.5 km in length and reaching a maximum height of 106 m (Husband Hill) above the plains of Spirit's landing site. As of this writing Spirit has been exploring the Columbia Hills for over 440 sols (since sol 156 on June 11, 2004). Thus far the origin of the Columbia Hills has remained elusive despite detailed analysis of numerous rock and soil targets, including outcrops. The chemical differences among the 6 distinct rock classes attest to the lithologic diversity and geologic complexity of the Hills. Origin of the Columbia Hills Several hypothesis have been put forth to explain the origin of the Columbia Hills: Old eroded partially buried impact crater rim(s), central peak, residual intracrater fill material, volcanic construct, wrinkle ridge, delta and or combinations of the above. Observations that support various aspects of these multiple hypotheses will be discussed. Numerous buried craters are observed on the floor of Gusev lending credence to the idea that the Columbia Hills are the remains of an ancient impact crater rim or possibly a central peak. Morphologic evidence of the rim of Thira crater and the Columbia Hills appears to support this hypothesis. The Aeolis region contains numerous craters that contain layered materials in the absence of any major fluvial systems. This could imply that the Columbia Hills are the remnants of a formerly extensive unit(s). Gusev contains many hills scattered across its floor such as Grissom, White, Chaffee and numerous other buttes and mesas that may be remnants of a former extensive intracrater deposit. Another possibility is that the Columbia Hills are composed of volcanic materials (cinder cones and associated ash and lava flows) derived either locally or from Apollinaris Patera located 300 km to the north. Several depressions are located in the Columbia Hills. These features could be calderas but are most likely impact craters. The most

  9. One-pot catalyst preparation : combined detemplating and Fe ionexchange of BEA through Fenton's chemistry

    NARCIS (Netherlands)

    Melián-Cabrera, I.; Kapteijn, F.; Moulijn, J.A.

    2005-01-01

    BEA zeolite has been simultaneously detemplated and Fe-exchanged by treating the parent zeolite with a Fenton's-type reagent (Fe3+ - H2O2) at low temperature. This one-pot process simplifies and speeds up considerably the preparation route. The catalyst shows excellent performance on N2O

  10. The Hill Chart Calculation for Pelton Runner Models using the HydroHillChart - Pelton Module Software

    Directory of Open Access Journals (Sweden)

    Adelina Bostan

    2015-07-01

    Full Text Available The Pelton turbines industrial design is based on the hill chart characteristics obtained by measuring the models. Primary data measurements used to obtain the hill chart can be processed graphically, by hand or by using graphic programs respectively CAD programs; the HydroHillChart - Pelton module software is a specialized tool in achieving the hill chart, using interpolation cubic spline functions. Thereby, based on measurements of several models of Pelton turbines, a computerized library, used to design industrial Pelton turbines can be created. The paper presents the universal characteristics calculated by using the HydroHillChart - Pelton module software for a series of Pelton runners.

  11. HTGR-GT closed-cycle gas turbine: a plant concept with inherent cogeneration (power plus heat production) capability

    International Nuclear Information System (INIS)

    McDonald, C.F.

    1980-04-01

    The high-grade sensible heat rejection characteristic of the high-temperature gas-cooled reactor-gas turbine (HTGR-GT) plant is ideally suited to cogeneration. Cogeneration in this nuclear closed-cycle plant could include (1) bottoming Rankine cycle, (2) hot water or process steam production, (3) desalination, and (4) urban and industrial district heating. This paper discusses the HTGR-GT plant thermodynamic cycles, design features, and potential applications for the cogeneration operation modes. This paper concludes that the HTGR-GT plant, which can potentially approach a 50% overall efficiency in a combined cycle mode, can significantly aid national energy goals, particularly resource conservation

  12. Effects of inorganic anions on carbon isotope fractionation during Fenton-like degradation of trichloroethene

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yunde [State Key Laboratory of Biogeology and Environmental Geology, China University of Geosciences, Wuhan 430074 (China); School of Environmental Studies, China University of Geosciences, Wuhan 430074 (China); Laboratory of Basin Hydrology and Wetland Eco-restoration, China University of Geosciences, Wuhan 430074 (China); Zhou, Aiguo, E-mail: aiguozhou@cug.edu.cn [State Key Laboratory of Biogeology and Environmental Geology, China University of Geosciences, Wuhan 430074 (China); School of Environmental Studies, China University of Geosciences, Wuhan 430074 (China); Gan, Yiqun; Li, Xiaoqian [State Key Laboratory of Biogeology and Environmental Geology, China University of Geosciences, Wuhan 430074 (China); School of Environmental Studies, China University of Geosciences, Wuhan 430074 (China)

    2016-05-05

    Highlights: • The effect of inorganic anions on carbon isotope fractionation was evaluated. • The enrichment factors was independent concentration of NO{sub 3}{sup −}, or SO{sub 4}{sup 2−}. • Cl{sup −} significantly influenced the carbon isotope fractionation. - Abstract: Understanding the magnitude and variability in isotope fractionation with respect to specific processes is crucial to the application of stable isotopic analysis as a tool to infer and quantify transformation processes. The variability of carbon isotope fractionation during Fenton-like degradation of trichloroethene (TCE) in the presence of different inorganic ions (nitrate, sulfate, and chloride), was investigated to evaluate the potential effects of inorganic anions on carbon isotope enrichment factor (ε value). A comparison of ε values obtained in deionized water, nitrate solution, and sulfate solution demonstrated that the ε values were identical and not affected by the presence of nitrate and sulfate. In the presence of chloride, however, the ε values (ranging from −6.3 ± 0.8 to 10 ± 1.3‰) were variable and depended on the chloride concentration, indicating that chloride could significantly affect carbon isotope fractionation during Fenton-like degradation of TCE. Thus, caution should be exercised in selecting appropriate ε values for the field application of stable isotope analysis, as various chloride concentrations may be present due to naturally present or introduced with pH adjustment and iron salts during Fenton-like remediation. Furthermore, the effects of chloride on carbon isotope fractionation may be able to provide new insights about reaction mechanisms of Fenton-like processes.

  13. Effects of inorganic anions on carbon isotope fractionation during Fenton-like degradation of trichloroethene

    International Nuclear Information System (INIS)

    Liu, Yunde; Zhou, Aiguo; Gan, Yiqun; Li, Xiaoqian

    2016-01-01

    Highlights: • The effect of inorganic anions on carbon isotope fractionation was evaluated. • The enrichment factors was independent concentration of NO_3"−, or SO_4"2"−. • Cl"− significantly influenced the carbon isotope fractionation. - Abstract: Understanding the magnitude and variability in isotope fractionation with respect to specific processes is crucial to the application of stable isotopic analysis as a tool to infer and quantify transformation processes. The variability of carbon isotope fractionation during Fenton-like degradation of trichloroethene (TCE) in the presence of different inorganic ions (nitrate, sulfate, and chloride), was investigated to evaluate the potential effects of inorganic anions on carbon isotope enrichment factor (ε value). A comparison of ε values obtained in deionized water, nitrate solution, and sulfate solution demonstrated that the ε values were identical and not affected by the presence of nitrate and sulfate. In the presence of chloride, however, the ε values (ranging from −6.3 ± 0.8 to 10 ± 1.3‰) were variable and depended on the chloride concentration, indicating that chloride could significantly affect carbon isotope fractionation during Fenton-like degradation of TCE. Thus, caution should be exercised in selecting appropriate ε values for the field application of stable isotope analysis, as various chloride concentrations may be present due to naturally present or introduced with pH adjustment and iron salts during Fenton-like remediation. Furthermore, the effects of chloride on carbon isotope fractionation may be able to provide new insights about reaction mechanisms of Fenton-like processes.

  14. Tratamento de águas contaminadas por diesel/biodiesel utilizando processo Fenton Treatment of water contaminated by diesel/biodiesel using Fenton process

    Directory of Open Access Journals (Sweden)

    Teofani Koslides Mitre

    2012-06-01

    Full Text Available A contaminação de águas por misturas diesel/biodiesel pode causar grandes impactos ambientais, relacionados à presença de compostos orgânicos recalcitrantes e tóxicos, inviabilizando o uso de processos biológicos de tratamento. A avaliação da biodegradabilidade, nas proporções B0, B25, B50, B75 e B100 (os números especificam o percentual em massa de biodiesel na mistura, indicou que a adição de biodiesel em teores acima de 50% aumenta a biodegradabilidade, alcançando 60 e 80% para B50 e B75, respectivamente. Na aplicação do processo Fenton, a remoção da matéria orgânica foi superior a 80% em todas as misturas, exceto para B0, que apresentou remoção máxima de 50%. A oxidação por Fenton se ajustou a um modelo cinético de pseudo-segunda ordem em relação à concentração de matéria orgânica, e resultou em aumento da biodegradabilidade de até 150%.Waters contaminated with diesel/biodiesel and their blends can cause major environmental impacts, due to the presence of toxic and recalcitrant organic compounds, which invalidate the use of biological treatment processes. Evaluation of biodegradability of the blends B0, B25, B50, B75 and B100 (the numbers specify the mass percentage of biodiesel in the blend indicated that the addition of biodiesel at concentrations above 50% increased biodegradation, reaching 60 and 80% for B50 and B75, respectively. When the Fenton process was used, removal of organic matter was greater than 80 % in all blends, except for B0, which showed maximum removal of 60%. Oxidation by Fenton was fitted with a pseudo-second order kinetic model in relation to the concentration of organic matter and resulted in increased biodegradation of up to 150%.

  15. Practical applications of the Fenton reaction to the removal of chlorinated aromatic pollutants. Oxidative degradation of 2,4-dichlorophenol.

    Science.gov (United States)

    Detomaso, Antonia; Lopez, Antonio; Lovecchio, Giangiuseppe; Mascolo, Giuseppe; Curci, Ruggero

    2003-01-01

    Chlorophenols (CPs) constitute a group of organic pollutants that are introduced into the environment as a result of several man-made activities, such as uncontrolled use of pesticides and herbicides, and as byproducts in the paper pulp bleaching. Promising removal technologies of chlorinated aromatics consist in the application of advanced oxidation processes (AOPs) that can provide an almost total degradation of a variety of contaminants. Among these, wide application find Fenton systems based on generation of reactive species having a high oxidizing power, such as hydroxyl radical HO*. Our objective was that of determining the overall degradation efficiency of the model compound 2,4-dichlorophenol (DCP) by thermal Fenton-type oxidation systems with a view toward defining in more details relevant process parameters, the effect of reaction temperature and of co-catalyst Cu2+. Reaction conditions were similar to those generally adopted as optimal in many practical applications, i.e. pollutant/Fe2+ (as FeSO4) ratio ca. 20, Fe2+/Cu2+ (co-catalyst) 2:1, pH adjusted and controlled at pH 3, and H2O2 in excess (up to four-fold over the stoichiometric amount required for complete mineralization). The results demonstrate that it is advantageous to carry out the reaction at a temperature markedly higher (70 degrees C) than ambient. The stepwise addition of H2O2 in aliquots yields an efficient transformation, while allowing a convenient control of the reaction exothermicity. Under these conditions, the essentially complete removal of the initial DCP is accomplished using just one equiv of H2O2 during 15 min; excess H2O2 (5 equivalents) yields extensive substrate mineralization. Also relevant, at 70 degrees C dechlorination of the initial DCP (and of derived reaction intermediates) is remarkably extensive (3-5% residual TOX), already with the addition of 1 equiv of H2O2. At the end of the reaction, IC and IC-MS analyses of the solution reveal that only low-molecular weight

  16. Iron-chelating agents never suppress Fenton reaction but participate in quenching spin-trapped radicals

    International Nuclear Information System (INIS)

    Li Linxiang; Abe, Yoshihiro; Kanagawa, Kiyotada; Shoji, Tomoko; Mashino, Tadahiko; Mochizuki, Masataka; Tanaka, Miho; Miyata, Naoki

    2007-01-01

    Hydroxyl radical formation by Fenton reaction in the presence of an iron-chelating agent such as EDTA was traced by two different assay methods; an electron spin resonance (ESR) spin-trapping method with 5,5-dimethyl-1-pyrroline N-oxide (DMPO), and high Performance liquid chromatography (HPLC)-fluorescence detection with terephthalic acid (TPA), a fluorescent probe for hydroxyl radicals. From the ESR spin-trapping measurement, it was observed that EDTA seemed to suppress hydroxyl radical formation with the increase of its concentration. On the other hand, hydroxyl radical formation by Fenton reaction was not affected by EDTA monitored by HPLC assay. Similar inconsistent effects of other iron-chelating agents such as nitrylotriacetic acid (NTA), diethylenetriamine penta acetic acid (DTPA), oxalate and citrate were also observed. On the addition of EDTA solution to the reaction mixture 10 min after the Fenton reaction started, when hydroxyl radical formation should have almost ceased but the ESR signal of DMPO-OH radicals could be detected, it was observed that the DMPO-OH· signal disappeared rapidly. With the simultaneous addition of Fe(II) solution and EDTA after the Fenton reaction ceased, the DMPO-OH· signal disappeared more rapidly. The results indicated that these chelating agents should enhance the quenching of [DMPO-OH]· radicals by Fe(II), but they did not suppress Fenton reaction by forming chelates with iron ions

  17. Loess Hills of Iowa

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — This coverage outlines the boundary of the Loess Hills in Iowa at 1:100,000 scale. Criteria applied to the delineation of the Loess Hills included drainage density,...

  18. Degradation of trans-ferulic acid in acidic aqueous medium by anodic oxidation, electro-Fenton and photoelectro-Fenton

    Energy Technology Data Exchange (ETDEWEB)

    Flores, Nelly; Sirés, Ignasi; Garrido, José Antonio; Centellas, Francesc; Rodríguez, Rosa María; Cabot, Pere Lluís; Brillas, Enric, E-mail: brillas@ub.edu

    2016-12-05

    Highlights: • trans-Ferulic acid degradation by EAOPs using a stirred BDD/air-diffusion cell. • Slow substrate abatement and poor mineralization by AO-H{sub 2}O{sub 2}. • 98% Mineralization by PEF, but with rapid and similar substrate decay than by EF. • Quicker degradation by SPEF due to the more potent photolytic action of sunlight. • Reaction pathway with four primary aromatic products and three final carboxylic acids. - Abstract: Solutions of pH 3.0 containing trans-ferulic acid, a phenolic compound in olive oil mill wastewater, have been comparatively degraded by anodic oxidation with electrogenerated H{sub 2}O{sub 2} (AO-H{sub 2}O{sub 2}), electro-Fenton (EF) and photoelectro-Fenton (PEF). Trials were performed with a BDD/air-diffusion cell, where oxidizing ·OH was produced from water discharge at the BDD anode and/or in the solution bulk from Fenton’s reaction between cathodically generated H{sub 2}O{sub 2} and added catalytic Fe{sup 2+}. The substrate was very slowly removed by AO-H{sub 2}O{sub 2}, whereas it was very rapidly abated by EF and PEF, at similar rate in both cases, due to its fast reaction with ·OH in the bulk. The AO-H{sub 2}O{sub 2} process yielded a slightly lower mineralization than EF, which promoted the accumulation of barely oxidizable products like Fe(III) complexes. In contrast, the fast photolysis of these latter species under irradiation with UVA light in PEF led to an almost total mineralization with 98% total organic carbon decay. The effect of current density and substrate concentration on the performance of all treatments was examined. Several solar PEF (SPEF) trials showed its viability for the treatment of wastewater containing trans-ferulic acid at larger scale. Four primary aromatic products were identified by GC–MS analysis of electrolyzed solutions, and final carboxylic acids like fumaric, acetic and oxalic were detected by ion-exclusion HPLC. A reaction sequence for trans-ferulic acid mineralization

  19. Confidence Hills Mineralogy and Chemin Results from Base of Mt. Sharp, Pahrump Hills, Gale Crater, Mars

    Science.gov (United States)

    Cavanagh, P. D.; Bish, D. L.; Blake, D. F.; Vaniman, D. T.; Morris, R. V.; Ming, D. W.; Rampe, E. B.; Achilles, C. N.; Chipera, S. J.; Treiman, A. H.; hide

    2015-01-01

    The Mars Science Laboratory (MSL) rover Curiosity recently completed its fourth drill sampling of sediments on Mars. The Confidence Hills (CH) sample was drilled from a rock located in the Pahrump Hills region at the base of Mt. Sharp in Gale Crater. The CheMin X-ray diffractometer completed five nights of analysis on the sample, more than previously executed for a drill sample, and the data have been analyzed using Rietveld refinement and full-pattern fitting to determine quantitative mineralogy. Confidence Hills mineralogy has several important characteristics: 1) abundant hematite and lesser magnetite; 2) a 10 angstrom phyllosilicate; 3) multiple feldspars including plagioclase and alkali feldspar; 4) mafic silicates including forsterite, orthopyroxene, and two types of clinopyroxene (Ca-rich and Ca-poor), consistent with a basaltic source; and 5) minor contributions from sulfur-bearing species including jarosite.

  20. Optimization of Fenton oxidation for the removal of methyl parathion in aqueous solution

    Directory of Open Access Journals (Sweden)

    Roli Saini

    2016-09-01

    Full Text Available In the present study, for the treatment of methyl parathion, Fenton oxidation is adopted. The aims of this study were (a to assess the removal efficiency in terms of chemical oxygen demand (COD, (b to scrutinize the influence of different parameters: initial pH, concentrations of H2O2 and Fe2+ and, (c response surface methodology (RSM was used to design the Fenton process. Three-level central composite design (CCD was applied in designing the experiments to observe the effects of most important operating factors. The enactment of the model was judged with the analysis of variance (ANOVA. A quadratic model was used to represent the experimental data. The predicted values and experimental values were found to be in good agreement with the (R2 = 0.9891 and Adj-R2 = 0.9877, which define the propriety of the model. The characteristic of methyl parathion bearing wastewater was concentration 30 mg/L, COD 440 mg/L, pH 6.5. Maximum removal efficiency was perceived at acidic pH value 3.

  1. Preparação do sistema Fe2O3/ZSM-5 para uso como catalisador na reação foto-Fenton

    Directory of Open Access Journals (Sweden)

    J. S. de Oliveira

    Full Text Available Resumo Este trabalho objetivou a preparação da zeólita ZSM-5 suportada com nanopartículas de óxido de ferro para uso como catalisador na degradação de um poluente orgânico em solução aquosa a partir do processo foto-Fenton. A zeólita foi preparada usando gel nucleante como indutor de formação da estrutura tipo MFI. Nanopartículas de óxido de ferro foram suportadas sobre a zeólita através da técnica de impregnação incipiente. Além disso, nanopartículas de óxido de ferro foram preparadas para fins de comparação entre as atividades catalíticas na reação foto-Fenton. Os materiais produzidos foram caracterizados por difração de raios X, microscopia eletrônica de varredura e análise de adsorção/dessorção de nitrogênio. Os resultados revelaram a formação do sistema Fe2O3/ZSM-5 com propriedades intrínsecas que resultaram em satisfatória atividade catalítica, sendo superior ao óxido de ferro. Além disso, esse sistema apresentou excelente atividade e estabilidade após três ciclos de reuso. O material Fe2O3/ZSM-5 produzido neste trabalho apresenta-se como um catalisador promissor para uso na reação foto-Fenton para a degradação de poluentes orgânicos em soluções aquosas.

  2. Evaluation of Fenton Oxidation Process Coupled with Biological Treatment for the Removal of Reactive Black 5 from Aqueous Solution

    Directory of Open Access Journals (Sweden)

    Pegah Bahmani

    2013-06-01

    Full Text Available Biodegradation of azo dyes is difficult due to their complex structures and low BOD to COD ratios. In the present study, the efficiency of using Fenton’s reagent (H2O2 + Fe2+ as a pretreatment process to enhance microbial transformation of reactive black 5 (RB5 in an aqueous system was evaluated. The RB5 with an initial concentration of 250 mg/L was decolorized up to 90% in 60 h by using a bacterial consortium. Fenton’s reagent at a Fe2+ concentration of 0.5 mM and H2O2 concentration of 2.9 mM (molar ratio, 1:5.8 was most effective for decolorization at pH = 3.0. The extent of RB5 removal by the combined Fenton–biotreatment was about 2 times higher than that of biotreatment alone. The production of some aromatic amines intermediates implied partial mineralization of the RB5 in Fenton treatment alone; in addition, decreasing of GC-MS peaks suggested that dearomatization occurred in Fenton-biological process. Fenton pretreatment seems to be a cost–effective option for the biotreatment of azo dyes, due mainly to the lower doses of chemicals, lower sludge generation, and saving of time. Our results demonstrated positive effects of inoculating bacterial consortium which was capable of dye biodegradation with a Fenton’s pretreatment step as well as the benefits of low time required for the biological process. In addition, the potential of field performance of Fenton-biological process because of using bacterial consortium is an other positive effect of it.

  3. CH2M Hill Hanford Group Inc (CHG) Information Resource Management (IRM) Strategic Plan

    Energy Technology Data Exchange (ETDEWEB)

    NELSON, R.L.

    2000-05-08

    The CH2M Hill Hanford Group, Inc., Information Resource Management Strategic Plan is the top-level planning document for applying information and information resource management to achieve the CHG mission for the management of the River Protection Project

  4. CH2M Hill Hanford Group Inc (CHG) Information Resource Management (IRM) Strategic Plan

    International Nuclear Information System (INIS)

    NELSON, R.L.

    2000-01-01

    The CH2M Hill Hanford Group, Inc., Information Resource Management Strategic Plan is the top-level planning document for applying information and information resource management to achieve the CHG mission for the management of the River Protection Project

  5. Elimination of pyraclostrobin by simultaneous microbial degradation coupled with the Fenton process in microbial fuel cells and the microbial community.

    Science.gov (United States)

    Zhao, Huanhuan; Kong, Chui-Hua

    2018-06-01

    The elimination of pyraclostrobin by simultaneous microbial degradation and Fenton oxidation was achieved in a microbial fuel cell (MFC) system. After 12 h of incubation, the removal rate of pyraclostrobin was 1.4 mg/L/h at the anode and 1.7 mg/L/h at the cathode. The pyraclostrobin concentration was less than the detection limit (0.1 mg/L) after 72 h at the anode and 24 h at the cathode. The air flow rate, temperature, and pH of the catholyte had significant effects on the generation of H 2 O 2 . The maximum production of H 2 O 2 was 1.2 mg/L after reaction for 20 h during the Fenton process. Microbial community analysis indicated that functional bacteria in the genera Chryseobacterium, Stenotrophomonas, Arcobacter, and Comamonas were predominant in the anodic biofilm. In conclusion, the MFC-Fenton system provides an effective approach for treating environmental contaminants. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Photovoltaics - 10 years after Cherry Hill

    Science.gov (United States)

    Ralph, E. L.

    The status of R&D programs connected with photovoltaic (PV) systems 10 years after the Cherry Hill workshop on 'Photovoltaic Conversion of Solar Energy for Terrestrial Applications' is assessed. The five categories of research recommended by the Cherry Hill Workshop are listed in a table together with their recommended research budget allocations. The workshop categories include: single-crystal Si cells; poly-Si cells; systems and diagnostics. Categories for thin film CdS/Cu2S and CuInSe2 cells are also included. The roles of government and private utility companies in providing adequate financial support for PV research programs is emphasized.

  7. Degradation of the azo dye Acid Red 1 by anodic oxidation and indirect electrochemical processes based on Fenton's reaction chemistry. Relationship between decolorization, mineralization and products

    International Nuclear Information System (INIS)

    Florenza, Xavier; Solano, Aline Maria Sales; Centellas, Francesc; Martínez-Huitle, Carlos Alberto

    2014-01-01

    Highlights: • Degradation of Acid Red 1 by anodic oxidation, electro-Fenton and photoelectro-Fenton • Quicker and similar decolorization by electro-Fenton and photoelectro-Fenton due to oxidation with ● OH in the bulk • Almost total mineralization by photoelectro-Fenton with Pt or BDD due to fast photolysis of products by UVA light • Detection of 11 aromatic products, 15 hydroxylated compounds, 13 desulfonated derivatives and 7 carboxylic acids • Release of NH 4 + , NO 3 − and SO 4 2− ions, and generation of persistent N-products of low molecular mass - Abstract: Solutions of 236 mg dm −3 Acid Red 1 (AR1), an azo dye widely used in textile dying industries, at pH 3.0 have been comparatively treated by anodic oxidation with electrogenerated H 2 O 2 (AO-H 2 O 2 ), electro-Fenton (EF) and photoelectro-Fenton (PEF) at constant current density (j). Assays were performed with a stirred tank reactor equipped with a Pt or boron-doped diamond (BDD) anode and an air-diffusion cathode for H 2 O 2 generation from O 2 reduction. The main oxidizing agents were hydroxyl radicals produced at the anode from water oxidation in all methods and in the bulk from Fenton's reaction between generated H 2 O 2 and 0.5 mmol dm −3 Fe 2+ in EF and PEF. For each anode, higher oxidation power was found in the sequence AO-H 2 O 2 < EF < PEF. The oxidation ability of the BDD anode was always superior to that of Pt. Faster and similar decolorization efficiency was achieved in EF and PEF owing to the quicker destruction of aromatics with hydroxyl radicals produced in the bulk. The PEF process with BDD was the most potent method yielding almost total mineralization due to the additional rapid photolysis of recalcitrant intermediates like Fe(III)-carboxylate complexes under UVA irradiation. The increase in j always enhanced the decolorization and mineralization processes because of the greater production of hydroxyl radicals, but decreases the mineralization current efficiency

  8. Quick photo-Fenton degradation of phenolic compounds by Cu/Al2O3-MCM-41 under visible light irradiation: small particle size, stabilization of copper, easy reducibility of Cu and visible light active material.

    Science.gov (United States)

    Pradhan, Amaresh C; Nanda, Binita; Parida, K M; Das, Mira

    2013-01-14

    The present study reports the photo-Fenton degradation of phenolic compounds (phenol, 2-chloro-4-nitrophenol and 4-chloro-2-nitrophenol) in aqueous solution using mesoporous Cu/Al(2)O(3)-MCM-41 nanocomposite as a heterogeneous photo-Fenton-like catalyst. The in situ incorporation of mesoporous Al(2)O(3) (MA) into the framework of MCM-41 (sol-gel method) forms Al(2)O(3)-MCM-41 and wetness impregnation of Cu(II) on Al(2)O(3)-MCM-41 generates mesoporous Cu/Al(2)O(3)-MCM-41 composite. The effects of pH and H(2)O(2) concentration on degradation of phenol, 2-chloro-4-nitrophenol and 4-chloro-2-nitrophenol are studied. Kinetics analysis shows that the photocatalytic degradation reaction follows a first-order rate equation. Mesoporous 5 Cu/Al(2)O(3)-MCM-41 is found to be an efficient photo-Fenton-like catalyst for the degradation of phenolic compounds. It shows nearly 100% degradation in 45 min at pH 4. The combined effect of small particle size, stabilization of Cu(2+) on the support Al(2)O(3)-MCM-41, ease reducibility of Cu(2+) and visible light activeness are the key factors for quick degradation of phenolic compounds by Cu/Al(2)O(3)-MCM-41.

  9. A Bio-Electro-Fenton System Employing the Composite FePc/CNT/SS316 Cathode

    Directory of Open Access Journals (Sweden)

    Yi-Ta Wang

    2017-02-01

    Full Text Available Bio-electro-Fenton microbial fuel cells generate energy through the decomposition of organic matter by microorganisms. The generated electricity drives a Fenton reaction in a cathode chamber, which can be used for the decolorization of dye wastewater. Most of the previous works added expensive platinum catalyst to improve the electrical property of the system. In this research, aligned carbon nanotubes (CNTs were generated on the surface of SS316 stainless steel by chemical vapor deposition, and an iron phthalocyanine (FePc catalyst was added to fabricate a compound (FePc/CNT/SS316 that was applied to the cathode electrode of the fuel cell system. This was expected to improve the overall electricity generation efficiency and extent of decolorization of the system. The results showed that the maximum current density of the system with the modified electrode was 3206.30 mA/m2, and the maximum power was 726.55 mW/m2, which were increased by 937 and 2594 times, respectively, compared to the current and power densities of a system where only the SS316 stainless steel electrode was used. In addition, the decolorization of RB5 dye reached 84.6% within 12 h. Measurements of the electrical properties of bio-electro-Fenton microbial fuel cells and dye decolorization experiments with the FePc/CNT/SS316 electrode showed good results.

  10. Complete removal of AHPS synthetic dye from water using new electro-fenton oxidation catalyzed by natural pyrite as heterogeneous catalyst.

    Science.gov (United States)

    Labiadh, Lazhar; Oturan, Mehmet A; Panizza, Marco; Hamadi, Nawfel Ben; Ammar, Salah

    2015-10-30

    The mineralization of a new azo dye - the (4-amino-3-hydroxy-2-p-tolylazo-naphthalene-1-sulfonic acid) (AHPS) - has been studied by a novel electrochemical advanced oxidation process (EAOP), consisting in electro-Fenton (EF) oxidation, catalyzed by pyrite as the heterogeneous catalyst - the so-called 'pyrite-EF'. This solid pyrite used as heterogeneous catalyst instead of a soluble iron salt, is the catalyst the system needs for production of hydroxyl radicals. Experiments were performed in an undivided cell equipped with a BDD anode and a commercial carbon felt cathode to electrogenerate in situ H2O2 and regenerate ferrous ions as catalyst. The effects on operating parameters, such as applied current, pyrite concentration and initial dye content, were investigated. AHPS decay and mineralization efficiencies were monitored by HPLC analyses and TOC measurements, respectively. Experimental results showed that AHPS was quickly oxidized by hydroxyl radicals (OH) produced simultaneously both on BDD surface by water discharge and in solution bulk from electrochemically assisted Fenton's reaction with a pseudo-first-order reaction. AHPS solutions with 175 mg L(-1) (100 mg L(-1) initial TOC) content were then almost completely mineralized in 8h. Moreover, the results demonstrated that, under the same conditions, AHPS degradation by pyrite electro-Fenton process was more powerful than the conventional electro-Fenton process. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Decolorization of Diazo Dye Ponceau S by Fenton Process

    International Nuclear Information System (INIS)

    Muslim, M.; Habib, M.A.; Islam, T.S.A.; Mahmood, A.J.; Ismail, I.M.I.

    2013-01-01

    An attempt has been taken to decolorize and mineralize Ponceau S (PS), a diazo dye, in aqueous solution by Fenton process. Effects of solution pH, concentrations of H/sub 2/O/sub 2/, Fe(II) and PS on the decolorization of PS have also been studied through batch experiments. About 90percentage decolorization was found under the optimal conditions (PS): (H/sub 2/O/sub 2/): (Fe(II)) = 1:12:2 and (H/sub 2/O/sub 2/)/(Fe(II)) = 6 at pH 2.85 in 40 minutes. The overall results revealed that mineralization was rather slower as compared with the decolorization. (author)

  12. Scaled-up electrochemical reactor with a fixed bed three-dimensional cathode for electro-Fenton process: Application to the treatment of bisphenol A

    International Nuclear Information System (INIS)

    Chmayssem, Ayman; Taha, Samir; Hauchard, Didier

    2017-01-01

    In this study, we report on the development of an open undivided electrochemical reactor with a compact fixed bed of glassy carbon pellets as three-dimensional cathode for the application of electro-Fenton process. Bisphenol A (BPA) was chosen as model molecule in order to improve its efficiency to the treatment of persistent pollutants. The study of the BPA removal efficiency in function of the applied current intensity was investigated in order to determine the limiting current of O 2 reduction (optimal conditions of H 2 O 2 production at flow rate of 0.36 m 3 .h −1 ) which was 0.8 A (0.5 A/100 g of glassy carbon pellets). Many parameters have been carried out using this electro-Fenton reactor namely degradation kinetics, influence of anodic reactions on DSA, effect of initial pollutant concentration. In the optimal current condition, the global production rate of H 2 O 2 and ·OH was investigated. The yield of electro-Fenton reaction (conversion of H 2 O 2 to ·OH) was very high (> 90%). The absolute rate of BPA degradation was determined as 4.3 × 10 9 M −1 s −1 . COD, TOC and BOD 5 measurements indicated that only few minutes of treatment by electro-Fenton process were needed to eliminate BPA for dilute solutions (10 and 25 mg.L −1 ). In this case, the biodegradability of the treated solutions occurred rapidly. For higher concentration levels, an efficient removal of BPA appeared for treatment time higher than 1 hour and more than 90 minutes were necessary to obtain the biodegradability of BPA solutions. In optimum conditions, the scale-up of the electrochemical reactor applied to electro-Fenton process was suggested and depended on the concentration level of the pollutant. The operating parameters of the scaled-up reactor might be deduced from the new section of each fixed bed exposed to the flow, from values of liquid flow velocity and from the corresponding limiting current density obtained with the reactor at laboratory scale. The compact fixed bed

  13. A study on removal of elemental mercury in flue gas using fenton solution

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yangxian; Wang, Yan; Wang, Qian; Pan, Jianfeng [School of Energy and Power Engineering, Jiangsu University, Zhenjiang, Jiangsu 212013 (China); Zhang, Yongchun [Jiangsu Province Special Equipment Safety Supervision Inspection Institute (Branch of Wuxi), Wuxi 214000 (China); Zhou, Jianfei [School of Energy and Power Engineering, Jiangsu University, Zhenjiang, Jiangsu 212013 (China); Zhang, Jun [Key Laboratory of Energy Thermal Conversion and Control of Ministry of Education, Southeast University, Nanjing 210096 (China)

    2015-07-15

    Highlights: • A novel technique on oxidation of Hg{sup 0} using Fenton was proposed. • The effects of several process parameters on Hg{sup 0} removal were studied. • Products and ·OH in solution were detected. • Reaction mechanism of Hg{sup 0} removal was studied. • Simultaneous removal of Hg{sup 0}, NO and SO{sub 2} was also studied. - Abstract: A novel technique on oxidation-separation of elemental mercury (Hg{sup 0}) in flue gas using Fenton solution in a bubbling reactor was proposed. The effects of several process parameters (H{sub 2}O{sub 2} concentration, Hg{sup 0} inlet concentration, Fe{sup 2+} concentration, solution temperature, solution pH, gas flow) and several flue gas components (NO, SO{sub 2}, O{sub 2}, CO{sub 2}, inorganic ions and particulate matters on Hg{sup 0} removal were studied. The results indicate that H{sub 2}O{sub 2} concentration, Fe{sup 2+} concentration, solution pH and gas flow have great effects on Hg{sup 0} removal. Solution temperature, Hg{sup 0}, NO, SO{sub 2}, CO{sub 3}{sup 2−} and HCO{sub 3}{sup −} concentrations also have significant effects on Hg{sup 0} removal. However, Cl{sup −}, SO{sub 4}{sup 2−}, NO{sub 3}{sup −}, O{sub 2} and CO{sub 2} concentrations only have slight effects on Hg{sup 0} removal. Furthermore, reaction mechanism of Hg{sup 0} removal and simultaneous removal process of Hg{sup 0}, NO and SO{sub 2} were also studied. Hg{sup 0} is removed by oxidation of ·OH and oxidation of H{sub 2}O{sub 2}. The simultaneous removal efficiencies of 100% for SO{sub 2}, 100% for Hg{sup 0} and 88.3% for NO were obtained under optimal test conditions. The results demonstrated the feasibility of Hg{sup 0} removal and simultaneous removal of Hg{sup 0}, SO{sub 2} and NO using Fenton solution in a bubbling reactor.

  14. Immobilizing LaFeO3 nanoparticles on carbon spheres for enhanced heterogeneous photo-Fenton like performance

    Science.gov (United States)

    Wang, Kaixuan; Niu, Helin; Chen, Jingshuai; Song, Jiming; Mao, Changjie; Zhang, Shengyi; Gao, Yuanhao

    2017-05-01

    LaFeO3 nanoparticles immobilized on the surface of monodisperse carbon spheres have been obtained through a facile and environmentally friendly ultrasonic assisted surface ions adsorption method. The LaFeO3/C nanocomposite was evaluated as photo-Fenton like catalyst for the degradation of Rhodamine B (RhB) under visible light irradiation (λ > 420 nm). The LaFeO3/C nanocomposite possesses high specific surface area compared with pure LaFeO3 and significantly enhanced photo-Fenton like catalytic performance. The possible formation process of the LaFeO3/C nanocomposite and the mechanism for photo-Fenton like reaction were discussed. The superior property was attributed to the synergistic effects from the photo-Fenton like process and the presence of carbon spheres. In addition, the heterogeneous process led to better recyclability of this type of catalyst.

  15. HTGR-GT primary coolant transient resulting from postulated turbine deblading

    International Nuclear Information System (INIS)

    Cadwallader, G.J.; Deremer, R.K.

    1980-11-01

    The turbomachine is located within the primary coolant system of a nuclear closed cycle gas turbine plant (HTGR-GT). The deblading of the turbine can cause a rapid pressure equilibration transient that generates significant loads on other components in the system. Prediction of and design for this transient are important aspects of assuring the safety of the HTGR-GT. This paper describes the adaptation and use of the RATSAM program to analyze the rapid fluid transient throughout the primary coolant system during a spectrum of turbine deblading events. Included are discussions of (1) specific modifications and improvements to the basic RATSAM program, which is also briefly described; (2) typical results showing the expansion wave moving upstream from the debladed turbine through the primary coolant system; and (3) the effect on the transient results of different plenum volumes, flow resistances, times to deblade, and geometries that can choke the flow

  16. CH2M Hill Hanford Group Inc (CHG) Information Resource Management (IRM) Strategic Plan

    Energy Technology Data Exchange (ETDEWEB)

    NELSON, R.L.

    2000-06-06

    The CH2M HILL Hanford Group, Inc. (CHG), Information Resource Management Strategic Plan is the top-level planning document for applying information and information resource management to achieve the CHG mission for the management of the River Protection Project waste tank farm.

  17. CH2M Hill Hanford Group Inc (CHG) Information Resource Management (IRM) Strategic Plan

    International Nuclear Information System (INIS)

    NELSON, R.L.

    2000-01-01

    The CH2M HILL Hanford Group, Inc. (CHG), Information Resource Management Strategic Plan is the top-level planning document for applying information and information resource management to achieve the CHG mission for the management of the River Protection Project waste tank farm

  18. Visualisasi Hasil Mesin Uji Tarik Gotech GT-7010-D2E dalam Bentuk Grafik secara Real Time

    OpenAIRE

    Anggoro Suryo Pramudyo; Andi Rachmansyah; Suhendar

    2014-01-01

    Gotech GT-7010-D2E is a tensile testing machine used in Metallurgical Engineering Laboratory UNTIRTA. The machine are used both for practical and Materials Engineering specimen testing demanded by several industries. The machine can perform tensile tests well, but for the analysis is done manually, so it requires a lot of time and accuracy of the analysis results are not very accurate. Therefore, it’s needed a software that can analyze the results of the tensile test in the form of graphs in ...

  19. Fenton Process Coupled to Ultrasound and UV Light Irradiation for the Oxidation of a Model Pollutant

    Directory of Open Access Journals (Sweden)

    Karen E. Barrera-Salgado

    2016-01-01

    Full Text Available The Fenton process coupled to photosonolysis (UV light and Us, using Fe2O3 catalyst supported on Al2O3, was used to oxidize a model pollutant like acid green 50 textile dye (AG50. Dye degradation was followed by AG50 concentration decay analyses. It was observed that parameters like iron content on a fixed amount of catalyst supporting material, catalyst annealing temperature, initial dye concentration, and the solution pH influence the overall treatment efficiency. High removal efficiencies of the model pollutant are achieved. The stability and reusability tests of the Fe2O3 catalyst show that the catalyst can be used up to three cycles achieving high discoloration. Thus, this catalyst is highly efficient for the degradation of AG50 in the Fenton process.

  20. Immobilizing LaFeO{sub 3} nanoparticles on carbon spheres for enhanced heterogeneous photo-Fenton like performance

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Kaixuan [School of Chemistry and Chemical Engineering, Anhui University, Hefei 230601 (China); Niu, Helin, E-mail: niuhelin@ahu.edu.cn [School of Chemistry and Chemical Engineering, Anhui University, Hefei 230601 (China); Chen, Jingshuai; Song, Jiming; Mao, Changjie; Zhang, Shengyi [School of Chemistry and Chemical Engineering, Anhui University, Hefei 230601 (China); Gao, Yuanhao [Institute of Surface Micro and Nano Materials, Xuchang University, Henan 461000 (China)

    2017-05-15

    Highlights: • LaFeO{sub 3} nanoparticles sub–10 nm were successfully immobilized on monodisperse carbon spheres for the first time through a facile and environmental friendly ultrasonic assisted surface ions adsorption method. • LaFeO{sub 3}/C nanocomposite exhibits much higher photo-Fenton like catalytic activity than LaFeO{sub 3}. • The superior property was attributed to the synergistic effects from the photo-Fenton like process and the presence of monodisperse carbon spheres. - Abstract: LaFeO{sub 3} nanoparticles immobilized on the surface of monodisperse carbon spheres have been obtained through a facile and environmentally friendly ultrasonic assisted surface ions adsorption method. The LaFeO{sub 3}/C nanocomposite was evaluated as photo-Fenton like catalyst for the degradation of Rhodamine B (RhB) under visible light irradiation (λ > 420 nm). The LaFeO{sub 3}/C nanocomposite possesses high specific surface area compared with pure LaFeO{sub 3} and significantly enhanced photo-Fenton like catalytic performance. The possible formation process of the LaFeO{sub 3}/C nanocomposite and the mechanism for photo-Fenton like reaction were discussed. The superior property was attributed to the synergistic effects from the photo-Fenton like process and the presence of carbon spheres. In addition, the heterogeneous process led to better recyclability of this type of catalyst.

  1. Turbo-machine deployment of HTR-10 GT

    International Nuclear Information System (INIS)

    Zhu Shutang; Wang Jie; Zhang Zhengming; Yu Suyuan

    2005-01-01

    As a testing project of gas turbine modular High Temperature Gas-cooled Reactor (HTGR), HTR-10GT has been studied and developed by Institute of Nuclear and New Energy Technology (INET) of Tsinghua University after the success of HTR-10 with steam turbine cycle. The main purposes of this project are to demonstrate the gas turbine modular HTGR, to optimize the deployment of Power Conversion Unit (PCU) and to verify the techniques of turbo-machine, operating modes and controlling measures. HTR-10GT is concentrated on the PCU design and the turbo-machine deployment. Possible turbo-machine deployments have been investigated and two of them are introduced in this paper. The preliminary design for the turbo-machine of HTR-10GT is single-shaft of vertical layout, arranged by the side of the reactor and the turbo-compressor rotary speed was selected to be 250 s -1 (15000 r/min) by considering the efficiency of turbo-compressor blade systems, the strength conditions and the mass and size characteristics of the turbo-compressor. The rotor system will be supported by electromagnetic bearings (EMBs) to curb the possible pollutions of the primary loop. Of all the components in this design, the high speed turbo-generator seems to be a world-wide technical nut. As an alternative design, a gearbox complex is used to reduce the rotary speed from the turbo-compressor 250 s -1 to 50 s -1 so that the ordinary generator can be used. (authors)

  2. Comparison of INTERGROWTH-21 and Fenton growth standards to assess size at birth and extrauterine growth in very preterm infants.

    Science.gov (United States)

    Tuzun, Funda; Yucesoy, Ebru; Baysal, Bora; Kumral, Abdullah; Duman, Nuray; Ozkan, Hasan

    2018-09-01

    This study aimed to compare the recently published prescriptive INTERGROWTH-21st standards with commonly used intrauterine based Fenton growth standards in terms of birth size classification and extrauterine growth restriction (EUGR) incidence in a sample of very preterm infants. The anthropometric measures of preterm infants born before 32 weeks of gestation at the Dokuz Eylul University Hospital during the period from January 2012 to February 2016 were obtained at birth, at the 36th gestational weeks or at the time of discharge. Birth and growth data were presented as percentiles according to the two reference standards. A total of 248 infants with mean gestational age of 29.1 ± 2.1 weeks were included. The small for gestational age (SGA) rate was significantly higher (12 versus 15%, p = .004) and the EUGR rate was significantly lower (40.2 versus 31.5%, p Fentons'. Twenty-four per cent of the infants who were accepted as SGA according to the INTERGROWTH-21st standards were appropriate for gestational age (AGA) according to the Fenton preterm growth charts. However, these newly identified SGA infants according to the Intergrowth-21st standards did not have increased risks of early morbidities. Furthermore, 77% of the cases who had EUGR due to the Fenton standards were categorized as EUGR when evaluated using the INTERGROWTH-21st standards. Results indicated that almost one out of every five cases assessed as EUGR according to Fenton standards was within the normal interval according to Intergrowth standards. On the contrary, one out of every four cases assessed as SGA according to the INTERGROWTH-21st standards was within the normal interval according to Fentons'. These differences observed with INTERGROWTH-21st standards may affect in-hospital and postdischarge nutrition plan of these vulnerable infants. However, new standards are needed to be evaluated against currently used ones before they are implemented and further studies should be conducted

  3. Antigravity hills are visual illusions.

    Science.gov (United States)

    Bressan, Paola; Garlaschelli, Luigi; Barracano, Monica

    2003-09-01

    Antigravity hills, also known as spook hills or magnetic hills, are natural places where cars put into neutral are seen to move uphill on a slightly sloping road, apparently defying the law of gravity. We show that these effects, popularly attributed to gravitational anomalies, are in fact visual illusions. We re-created all the known types of antigravity spots in our laboratory using tabletop models; the number of visible stretches of road, their slant, and the height of the visible horizon were systematically varied in four experiments. We conclude that antigravity-hill effects follow from a misperception of the eye level relative to gravity, caused by the presence of either contextual inclines or a false horizon line.

  4. Highly efficient Fenton and enzyme-mimetic activities of NH2-MIL-88B(Fe) metal organic framework for methylene blue degradation.

    Science.gov (United States)

    He, Jianchuan; Zhang, Yao; Zhang, Xiaodan; Huang, Yuming

    2018-03-26

    Here, we show that NH 2 -MIL-88B(Fe) can be used as a peroxidase-like catalyst for Fenton-like degradation of methylene blue (MB) in water. The iron-based NH 2 -MIL-88B(Fe) metal organic framework (MOF) was synthesized by a facile and rapid microwave heating method. It was characterized by scanning electron microscopy, Fourier transform infrared spectroscopy, powder X-ray diffraction, and the Brunauer-Emmett-Teller method. The NH 2 -MIL-88B(Fe) MOF possesses intrinsic oxidase-like and peroxidase-like activities. The reaction parameters that affect MB degradation were investigated, including the solution pH, NH 2 -MIL-88B(Fe) MOF and H 2 O 2 concentrations, and temperature. The results show that the NH 2 -MIL-88B(Fe) MOF exhibits a wide working pH range (pH 3.0-11.0), temperature tolerance, and good recyclability for MB removal. Under the optimal conditions, complete removal of MB was achieved within 45 min. In addition, removal of MB was above 80% after five cycles, showing the good recyclability of NH 2 -MIL-88B(Fe). The NH 2 -MIL-88B(Fe) MOF has the features of easy preparation, high efficiency, and good recyclability for MB removal in a wide pH range. Electron spin resonance and fluorescence probe results suggest the involvement of hydroxyl radicals in MB degradation. These findings provide new insight into the application of high-efficient MOF-based Fenton-like catalysts for water purification.

  5. Fenton chemistry-based detemplation of an industrially relevant microcrystalline beta zeolite. Optimization and scaling-up studies

    NARCIS (Netherlands)

    Ortiz-Iniesta, Maria Jesus; Melian-Cabrera, Ignacio

    A mild template removal of microcrystalline beta zeolite, based on Fenton chemistry, was optimized. Fenton detemplation was studied in terms of applicability conditions window, reaction rate and scale up. TGA and CHN elemental analysis were used to evaluate the detemplation effectiveness, while 'CP,

  6. Integration of processes induced air flotation and photo-Fenton for treatment of residual waters contaminated with xylene.

    Science.gov (United States)

    da Silva, Syllos S; Chiavone-Filho, Osvaldo; de Barros Neto, Eduardo L; Nascimento, Claudio A O

    2012-01-15

    Produced water in oil fields is one of the main sources of wastewater generated in the industry. It contains several organic compounds, such as benzene, toluene, ethyl benzene and xylene (BTEX), whose disposal is regulated by law. The aim of this study is to investigate a treatment of produced water integrating two processes, i.e., induced air flotation (IAF) and photo-Fenton. The experiments were conducted in a column flotation and annular lamp reactor for flotation and photodegradation steps, respectively. The first order kinetic constant of IAF for the wastewater studied was determined to be 0.1765 min(-1) for the surfactant EO 7. Degradation efficiencies of organic loading were assessed using factorial planning. Statistical data analysis shows that H(2)O(2) concentration is a determining factor in process efficiency. Degradations above 90% were reached in all cases after 90 min of reaction, attaining 100% mineralization in the optimized concentrations of Fenton reagents. Process integration was adequate with 100% organic load removal in 20 min. The results of the integration of the IAF with the photo-Fenton allowed to meet the effluent limits established by Brazilian legislation for disposal. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. 78 FR 73187 - Black Hills National Forest Advisory Board

    Science.gov (United States)

    2013-12-05

    ... DEPARTMENT OF AGRICULTURE Forest Service Black Hills National Forest Advisory Board AGENCY: Forest Service, USDA. ACTION: Notice of meeting. SUMMARY: The Black Hills National Forest Advisory Board (Board... all members of the Advisory Board; (2) provide orientation to Board Members on Basic Laws governing...

  8. Novel RGO/α-FeOOH supported catalyst for Fenton oxidation of phenol at a wide pH range using solar-light-driven irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Ying, E-mail: yingwang@bnu.edu.cn [The Key Laboratory of Water and Sediment Sciences, Ministry of Education, School of Environment, Beijing Normal University, Beijing 100875 (China); Fang, Jiasheng, E-mail: fangfangcanfly@163.com [The Key Laboratory of Water and Sediment Sciences, Ministry of Education, School of Environment, Beijing Normal University, Beijing 100875 (China); School of Chemistry and Chemical Engineering, Southeast University, Jiangsu Optoelectronic Functional Materials and Engineering Laboratory, Nanjing 211189 (China); Crittenden, John C., E-mail: John.Crittenden@ce.gatech.edu [School of Civil and Environmental Engineering and the Brook Byers Institute for Sustainable Systems, Georgia Institute of Technology, Atlanta, GA 30332-0595 (United States); Shen, Chanchan [The Key Laboratory of Water and Sediment Sciences, Ministry of Education, School of Environment, Beijing Normal University, Beijing 100875 (China)

    2017-05-05

    Graphical abstract: Schematic of the preparation of RF supported catalysts and the reaction mechanism for SLD Fenton catalytic degradation of aqueous phenol. - Highlights: • Novel SLD Fenton catalyst was synthesized via in-situ induced self-assembly process. • RGO improved light-harvesting capacity and enhanced electro-transport performance. • Visible light irradiation accelerated reaction and extended operating pHs (4.0–8.0). • H{sub 2}O{sub 2} reduction and H{sub 2}O oxidation yielded ·OH in Fe{sup Ⅱ}/Fe{sup Ⅲ} and Fe{sup Ⅲ}/Fe{sup Ⅳ} cycling process. - Abstract: A novel solar-light-driven (SLD) Fenton catalyst was developed by reducing the ferrous-ion onto graphene oxide (GO) and forming reduced graphene oxide/α-FeOOH composites (RF) via in-situ induced self-assembly process. The RF was supported on several mesoporous supports (i.e., Al-MCM-41, MCM-41 and γ-Al{sub 2}O{sub 3}). The activity, stability and energy use for phenol oxidation were systematically studied for a wide pH range. Furthermore, the catalytic mechanism at acid and alkaline aqueous conditions was also elucidated. The results showed that Fe(II) was reduced onto GO nanosheets and α-FeOOH crystals were formed during the self-assembly process. Compared with Fenton reaction without SLD irradiation, the visible light irradiation not only dramatically accelerated the rate of Fenton-based reactions, but also extended the operating pH for the Fenton reaction (from 4.0 to 8.0). The phenol oxidation on RF supported catalysts was fitting well with the pseudo-first-order kinetics, and needed low initiating energy, insensitive to the reacting temperature changes (273–318 K). The Al-MCM-41 supported RF was a more highly energy-efficient catalyst with the prominent catalytic activity at wide operating pHs. During the reaction, ·OH radicals were generated by the SLD irradiation from H{sub 2}O{sub 2} reduction and H{sub 2}O oxidation in the Fe{sup Ⅱ}/Fe{sup Ⅲ} and Fe{sup Ⅲ}/Fe{sup

  9. Tethyan Anhydrite Preserved in the Lower Ocean Crust of the Samail Ophiolite? Evidence from Oman Drilling Project Holes GT1A and 2A

    Science.gov (United States)

    Teagle, D. A. H.; Harris, M.; Crispini, L.; Deans, J. R.; Cooper, M. J.; Kelemen, P. B.; Alt, J.; Banerjee, N.; Shanks, W. C., III

    2017-12-01

    Anhydrite is important in mid-ocean ridge hydrothermal systems because of the high concentrations of calcium and sulfate in modern seawater and anhydrite's retrograde solubility. Because anhydrite hosts many powerful tracers of fluid-rock interactions (87Sr/86Sr, δ18O, δ34S, trace elements, fluid inclusions) it is useful for tracing the chemical evolution of hydrothermal recharge fluids and estimating time-integrated fluid fluxes. Anhydrite can form from heated seawater (>100°C), through water-rock reaction, or by mixing of seawater and hydrothermal fluids. Although abundant in active hydrothermal mounds, and predicted to form from downwelling, warming fluids during convection, anhydrite is rare in drill core from seafloor lavas, sheeted dikes and upper gabbros, with only minor amounts in ODP Holes 504B and 1256D. Because anhydrite can dissolve during weathering, its occurrence in ophiolites is unexpected. Instead, gypsum is present in Macquarie Island lavas and Miocene gypsum fills cavities within the Cretaceous Troodos ore deposits. Thus, the occurrence of numerous anhydrite veins in cores from the gabbroic lower crust of the Samail ophiolite in Oman was unanticipated. To our knowledge, anhydrite in Oman gabbros has not been previously reported. Oman Drilling Project Holes GT1A and GT2A were drilled into the Wadi Gideah section of the Wadi Tayin massif. Both recovered 400 m of continuous core from sections of layered gabbros (GT1) and the foliated-layered gabbro transition (GT2). Anhydrite is present throughout both holes, some in vein networks but more commonly as isolated 1-110 mm veins (>60 mm ave). Anhydrite is mostly the sole vein filling but can occur with greenschist minerals such as epidote, quartz, chlorite and prehnite. Anhydrite commonly exhibits prismatic and bladed textures but can also be capriciously microcrystalline. Though definitive cross cutting relationships are elusive, anhydrite veins cut across some greenschist veins. Anhydrite is

  10. Application of non-thermal plasma reactor and Fenton reaction for degradation of ibuprofen

    Energy Technology Data Exchange (ETDEWEB)

    Marković, Marijana [Center of Chemistry, Institute of Chemistry, Technology and Metallurgy, University of Belgrade, Studentski trg 12-16, 11000 Belgrade (Serbia); Jović, Milica; Stanković, Dalibor [Innovation Center, Faculty of Chemistry, University of Belgrade, P.O. Box 51, 11058 Belgrade 118 (Serbia); Kovačević, Vesna [Faculty of Physics, University of Belgrade, P.O. Box 44, 11000 Belgrade (Serbia); Roglić, Goran [Faculty of Chemistry, University of Belgrade, P.O. Box 51, 11058 Belgrade 118 (Serbia); Gojgić-Cvijović, Gordana [Center of Chemistry, Institute of Chemistry, Technology and Metallurgy, University of Belgrade, Studentski trg 12-16, 11000 Belgrade (Serbia); Manojlović, Dragan, E-mail: manojlo@chem.bg.ac.rs [Faculty of Chemistry, University of Belgrade, P.O. Box 51, 11058 Belgrade 118 (Serbia)

    2015-02-01

    Pharmaceutical compounds have been detected frequently in surface and ground water. Advanced Oxidation Processes (AOPs) were reported as very efficient for removal of various organic compounds. Nevertheless, due to incomplete degradation, toxic intermediates can induce more severe effects than the parent compound. Therefore, toxicity studies are necessary for the evaluation of possible uses of AOPs. In this study the effectiveness and capacity for environmental application of three different AOPs were estimated. They were applied and evaluated for removal of ibuprofen from water solutions. Therefore, two treatments were performed in a non-thermal plasma reactor with dielectric barrier discharge with and without a homogenous catalyst (Fe{sup 2+}). The third treatment was the Fenton reaction. The degradation rate of ibuprofen was measured by HPLC-DAD and the main degradation products were identified using LC–MS TOF. Twelve degradation products were identified, and there were differences according to the various treatments applied. Toxicity effects were determined with two bioassays: Vibrio fischeri and Artemia salina. The efficiency of AOPs was demonstrated for all treatments, where after 15 min degradation percentage was over 80% accompanied by opening of the aromatic ring. In the treatment with homogenous catalyst degradation reached 99%. V. fischeri toxicity test has shown greater sensitivity to ibuprofen solution after the Fenton treatment in comparison to A. salina. - Highlights: • Twelve ibuprofen degradation products were identified in total. • The degradation percentage differed between treatments (DBD/Fe{sup 2+} was 99%). • In DBD/Fe{sup 2+} only aliphatic degradation products were identified. • V. fischeri was sensitive to ibuprofen solution after the Fenton treatment. • A. salina showed no toxic effect when exposed to all post treatment solutions.

  11. Application of non-thermal plasma reactor and Fenton reaction for degradation of ibuprofen

    International Nuclear Information System (INIS)

    Marković, Marijana; Jović, Milica; Stanković, Dalibor; Kovačević, Vesna; Roglić, Goran; Gojgić-Cvijović, Gordana; Manojlović, Dragan

    2015-01-01

    Pharmaceutical compounds have been detected frequently in surface and ground water. Advanced Oxidation Processes (AOPs) were reported as very efficient for removal of various organic compounds. Nevertheless, due to incomplete degradation, toxic intermediates can induce more severe effects than the parent compound. Therefore, toxicity studies are necessary for the evaluation of possible uses of AOPs. In this study the effectiveness and capacity for environmental application of three different AOPs were estimated. They were applied and evaluated for removal of ibuprofen from water solutions. Therefore, two treatments were performed in a non-thermal plasma reactor with dielectric barrier discharge with and without a homogenous catalyst (Fe 2+ ). The third treatment was the Fenton reaction. The degradation rate of ibuprofen was measured by HPLC-DAD and the main degradation products were identified using LC–MS TOF. Twelve degradation products were identified, and there were differences according to the various treatments applied. Toxicity effects were determined with two bioassays: Vibrio fischeri and Artemia salina. The efficiency of AOPs was demonstrated for all treatments, where after 15 min degradation percentage was over 80% accompanied by opening of the aromatic ring. In the treatment with homogenous catalyst degradation reached 99%. V. fischeri toxicity test has shown greater sensitivity to ibuprofen solution after the Fenton treatment in comparison to A. salina. - Highlights: • Twelve ibuprofen degradation products were identified in total. • The degradation percentage differed between treatments (DBD/Fe 2+ was 99%). • In DBD/Fe 2+ only aliphatic degradation products were identified. • V. fischeri was sensitive to ibuprofen solution after the Fenton treatment. • A. salina showed no toxic effect when exposed to all post treatment solutions

  12. Treatment of textile effluent by chemical (Fenton's Reagent) and biological (sequencing batch reactor) oxidation

    International Nuclear Information System (INIS)

    Rodrigues, Carmen S.D.; Madeira, Luis M.; Boaventura, Rui A.R.

    2009-01-01

    The removal of organic compounds and colour from a synthetic effluent simulating a cotton dyeing wastewater was evaluated by using a combined process of Fenton's Reagent oxidation and biological degradation in a sequencing batch reactor (SBR). The experimental design methodology was first applied to the chemical oxidation process in order to determine the values of temperature, ferrous ion concentration and hydrogen peroxide concentration that maximize dissolved organic carbon (DOC) and colour removals and increase the effluent's biodegradability. Additional studies on the biological oxidation (SBR) of the raw and previously submitted to Fenton's oxidation effluent had been performed during 15 cycles (i.e., up to steady-state conditions), each one with the duration of 11.5 h; Fenton's oxidation was performed either in conditions that maximize the colour removal or the increase in the biodegradability. The obtained results allowed concluding that the combination of the two treatment processes provides much better removals of DOC, BOD 5 and colour than the biological or chemical treatment alone. Moreover, the removal of organic matter in the integrated process is particularly effective when Fenton's pre-oxidation is carried out under conditions that promote the maximum increase in wastewater biodegradability.

  13. Application of Electro-Fenton Technology to Remediation of Polluted Effluents by Self-Sustaining Process

    Directory of Open Access Journals (Sweden)

    Maria Ángeles Fernández de Dios

    2014-01-01

    Full Text Available The applicability of electro-Fenton technology to remediation of wastewater contaminated by several organic pollutants such as dyes and polycyclic aromatic hydrocarbons has been evaluated using iron-enriched zeolite as heterogeneous catalyst. The electro-Fenton technology is an advanced oxidation process that is efficient for the degradation of organic pollutants, but it suffers from the high operating costs due to the need for power investment. For this reason, in this study microbial fuel cells (MFCs were designed in order to supply electricity to electro-Fenton processes and to achieve high treatment efficiency at low cost. Initially, the effect of key parameters on the MFC power generation was evaluated. Afterwards, the degradation of Reactive Black 5 dye and phenanthrene was evaluated in an electro-Fenton reactor, containing iron-enriched zeolite as catalyst, using the electricity supplied by the MFC. Near complete dye decolourization and 78% of phenanthrene degradation were reached after 90 min and 30 h, respectively. Furthermore, preliminary reusability tests of the developed catalyst showed high degradation levels for successive cycles. The results permit concluding that the integrated system is adequate to achieve high treatment efficiency with low electrical consumption.

  14. Application of Electro-Fenton Technology to Remediation of Polluted Effluents by Self-Sustaining Process

    Science.gov (United States)

    Fernández de Dios, Maria Ángeles; Iglesias, Olaia; Pazos, Marta; Sanromán, Maria Ángeles

    2014-01-01

    The applicability of electro-Fenton technology to remediation of wastewater contaminated by several organic pollutants such as dyes and polycyclic aromatic hydrocarbons has been evaluated using iron-enriched zeolite as heterogeneous catalyst. The electro-Fenton technology is an advanced oxidation process that is efficient for the degradation of organic pollutants, but it suffers from the high operating costs due to the need for power investment. For this reason, in this study microbial fuel cells (MFCs) were designed in order to supply electricity to electro-Fenton processes and to achieve high treatment efficiency at low cost. Initially, the effect of key parameters on the MFC power generation was evaluated. Afterwards, the degradation of Reactive Black 5 dye and phenanthrene was evaluated in an electro-Fenton reactor, containing iron-enriched zeolite as catalyst, using the electricity supplied by the MFC. Near complete dye decolourization and 78% of phenanthrene degradation were reached after 90 min and 30 h, respectively. Furthermore, preliminary reusability tests of the developed catalyst showed high degradation levels for successive cycles. The results permit concluding that the integrated system is adequate to achieve high treatment efficiency with low electrical consumption. PMID:24723828

  15. Personal Review: Progress and prospect in electro-Fenton process for wastewater treatment

    Institute of Scientific and Technical Information of China (English)

    JIANG Cheng-chun; ZHANG Jia-fa

    2007-01-01

    As a novel advanced oxidation process (AOP), electro-Fenton process is powerful for degrading most organic compounds including toxic and non-biodegradable ones, and so has attracted great attention. This paper reviews this process in detail including the mechanism, electrolytic bath, electrode materials, aerations and operation parameters. The application of electro-Fenton method in wastewater treatment is evaluated and summarized. Future work in this field is suggested, and three main directions of new electrode exploitation, development of assisted technologies and mechanistic study should be strengthened.

  16. Application of Acid Cracking and Fenton Processes inTreating Olive Mill Wastewater

    Directory of Open Access Journals (Sweden)

    Majid Aliabadi

    2006-03-01

    Full Text Available In recent years, the growth in the industries of olive oil extraction has brought about a number of environmental problems. The waste water resulting from olive oil extraction can not be naturally degraded due to the presence of phenol, volatile fatty acids, catchin, and other recalcitrants.In recent years advanced oxidation processes based on hydroxyl radical are paid special attention by scientific, research and industrial centers to degrade the pollutants. In this study, a combination of acid cracking and advanced oxidation process in terms of Fenton process have been studied. Results showed that acid cracking can remove 97, 47, 30, 63 and 57 percent of Turbidity, COD, Total Phenols, Color and Aromaticity, respectively. Fenton process in pH=3 at optimal conditions can remove 57, 97, 18 and 32 percent of COD, Total Phenols, Color and Aromaticity, respectively. Necessary time of reaction was 4 hrs and optimum concentration of H2O2 and Fe2+ ions was determined 0. 5 M and 0.02 M, respectively. Increasing temperature in the range of 25-35°C and type of iron used(ferric or ferrous has no considerable effect in  the efficiency of the process.

  17. Effect of seven Indian plant extracts on Fenton reaction-mediated damage to DNA constituents.

    Science.gov (United States)

    Kar, Indrani; Chattopadhyaya, Rajagopal

    2017-11-01

    The influences of substoichiometric amounts of seven plant extracts in the Fenton reaction-mediated damage to deoxynucleosides, deoxynucleoside monophosphates, deoxynucleoside triphosphates, and supercoiled plasmid DNA were studied to rationalize anticancer properties reported in some of these extracts. Extracts from Acacia catechu, Emblica officinalis, Spondias dulcis, Terminalia belerica, Terminalia chebula, as well as gallic acid, epicatechin, chebulagic acid and chebulinic acid enhance the extent of damage in Fenton reactions with all monomeric substrates but protect supercoiled plasmid DNA, compared to standard Fenton reactions. The damage to pyrimidine nucleosides/nucleotides is enhanced by these extracts and compounds to a greater extent than for purine ones in a concentration dependent manner. Dolichos biflorus and Hemidesmus indicus extracts generally do not show this enhancement for the monomeric substrates though they protect plasmid DNA. Compared to standard Fenton reactions for deoxynucleosides with ethanol, the presence of these five plant extracts render ethanol scavenging less effective as the radical is generated in the vicinity of the target. Since substoichiometric amounts of these extracts and the four compounds produce this effect, a catalytic mechanism involving the presence of a ternary complex of the nucleoside/nucleotide substrate, a plant compound and the hydroxyl radical is proposed. Such a mechanism cannot operate for plasmid DNA as the planar rings in the extract compounds cannot stack with the duplex DNA bases. These plant extracts, by enhancing Fenton reaction-mediated damage to deoxynucleoside triphosphates, slow down DNA replication in rapidly dividing cancer cells, thus contributing to their anticancer properties.

  18. Citric Acid-Modified Fenton's Reaction for the Oxidation of Chlorinated Ethylenes in Soil Solution Systems

    Energy Technology Data Exchange (ETDEWEB)

    Seol, Yongkoo; Javandel, Iraj

    2008-03-15

    Fenton's reagent, a solution of hydrogen peroxide and ferrous iron catalyst, is used for an in-situ chemical oxidation of organic contaminants. Sulfuric acid is commonly used to create an acidic condition needed for catalytic oxidation. Fenton's reaction often involves pressure buildup and precipitation of reaction products, which can cause safety hazards and diminish efficiency. We selected citric acid, a food-grade substance, as an acidifying agent to evaluate its efficiencies for organic contaminant removal in Fenton's reaction, and examined the impacts of using citric acid on the unwanted reaction products. A series of batch and column experiments were performed with varying H{sub 2}O{sub 2} concentrations to decompose selected chlorinated ethylenes. Either dissolved iron from soil or iron sulfate salt was added to provide the iron catalyst in the batch tests. Batch experiments revealed that both citric and sulfuric acid systems achieved over 90% contaminant removal rates, and the presence of iron catalyst was essential for effective decontamination. Batch tests with citric acid showed no signs of pressure accumulation and solid precipitations, however the results suggested that an excessive usage of H{sub 2}O{sub 2} relative to iron catalysts (Fe{sup 2+}/H{sub 2}O{sub 2} < 1/330) would result in lowering the efficiency of contaminant removal by iron chelations in the citric acid system. Column tests confirmed that citric acid could provide suitable acidic conditions to achieve higher than 55% contaminant removal rates.

  19. Sistema de injeção em fluxo espectrofotométrico para monitorar peróxido de hidrogênio em processo de fotodegradação por reação foto-Fenton Flow injection spectrophotometric system for hydrogen peroxide monitoring in photo-Fenton degradation processes

    Directory of Open Access Journals (Sweden)

    Mirela C. Oliveira

    2001-04-01

    Full Text Available A flow injection spectrophotometric system was projected for monitoring hydrogen peroxide during photodegradation of organic contaminants in photo-Fenton processes (Fe2+/H2O2/UV. Sample is injected manually in a carrier stream and then receives by confluence a 0.1 mol L-1 NH4VO3 solution in 0.5 mol L-1 H2SO4 medium. The product formed shows absorption at 446 nm which is recorded as a peak with height proportional to H2O2 concentration. The performance of the proposed system was evaluated by monitoring the consumption of H2O2 during the photodegradation of dichloroacetic acid solution by foto-Fenton reaction.

  20. Detection of non-ΔGT NCF-1 mutations in chronic granulomatous disease

    DEFF Research Database (Denmark)

    Jakobsen, Marianne Antonius; Pedersen, Svend Stenvang; Barington, Torben

    2009-01-01

    to have mutations in NCF-1 encoding p47-phox, which is part of the cytosolic component of NADPH oxidase. More than 94% of these patients share the same mutation, a 2 bp GT deletion in the GTGT dinucleotide repeat in the start of exon 2. The presence of two pseudogenes more than 98% homologous...

  1. Fenton's Reagent. Innovative Technology Summary Report

    International Nuclear Information System (INIS)

    None

    1999-01-01

    The Fenton's Reagent DNAPL treatment process is an in situ oxidation method to destroy DNAPLs in groundwater. Residual industrial solvents, primarily Dense Non-Aqueous Phase Liquids (DNAPLs), are currently the most significant barrier to successful completion of most large groundwater and soil cleanup efforts. DNAPL pools and residues slowly dissolve into surrounding groundwater to create large plumes of organic solvent contamination with concentration levels far above regulatory limits

  2. Integration of processes induced air flotation and photo-Fenton for treatment of residual waters contaminated with xylene

    International Nuclear Information System (INIS)

    Silva, Syllos S. da; Chiavone-Filho, Osvaldo; Barros Neto, Eduardo L. de; Nascimento, Claudio A.O.

    2012-01-01

    Highlights: ► We have studied the treatment of wastewater contaminated with hydrocarbons represented by the xylene, using these processes in an integrated mode: induced air flotation and photo-Fenton. ► We have selected xylene as representative contaminant due to properties of toxicity, solubility in water and vapor pressure. ► The manuscript presents a series of accurate experimental data that can be useful for material and energy optimization purposes in the xylene removal aiming the treatment of oil field produced water. - Abstract: Produced water in oil fields is one of the main sources of wastewater generated in the industry. It contains several organic compounds, such as benzene, toluene, ethyl benzene and xylene (BTEX), whose disposal is regulated by law. The aim of this study is to investigate a treatment of produced water integrating two processes, i.e., induced air flotation (IAF) and photo-Fenton. The experiments were conducted in a column flotation and annular lamp reactor for flotation and photodegradation steps, respectively. The first order kinetic constant of IAF for the wastewater studied was determined to be 0.1765 min −1 for the surfactant EO 7. Degradation efficiencies of organic loading were assessed using factorial planning. Statistical data analysis shows that H 2 O 2 concentration is a determining factor in process efficiency. Degradations above 90% were reached in all cases after 90 min of reaction, attaining 100% mineralization in the optimized concentrations of Fenton reagents. Process integration was adequate with 100% organic load removal in 20 min. The results of the integration of the IAF with the photo-Fenton allowed to meet the effluent limits established by Brazilian legislation for disposal.

  3. An oxidative desulfurization method using ultrasound/Fenton's reagent for obtaining low and/or ultra-low sulfur diesel fuel

    Energy Technology Data Exchange (ETDEWEB)

    Dai, Yongchuan; Qi, Yutai [Department of Applied Chemistry, School of Science, Harbin Institute of Technology, Harbin 115001 (China); Zhao, Dezhi [Department of Petroleum Chemical Engineering, Liaoning Shihua University, Fushun 113001 (China); Zhang, Huicheng [Fushun Research Institute of Petroleum and Petrochemicals of SINOPEC Corp., Fushun 113001 (China)

    2008-10-15

    The total development trend in the world is towards continuously lower of sulfur content as a quality standard of diesel fuels. Integrating of an oxidative desulfurization unit with a conventional hydrotreating unit can bring benefits to producing low and/or ultra-low sulfur diesel fuels. Using the hydrotreated Middle East diesel fuel as a feedstock, four processes of the oxidative desulfurization have been studied: a hydrogen peroxide-acetic acid system and a Fenton's reagent system both without/with ultrasound. Results showed that the oxidative desulfurization reaction mechanics fitted apparent first-order kinetics. The addition of Fenton's reagent could enhance the oxidative desulfurization efficiency for diesel fuels and sono-oxidation treatment in combination with Fenton's reagent shows a good synergistic effect. Under our best operating condition for the oxidative desulfurization: temperature 313 K, ultrasonic power 200 W, ultrasonic frequency 28 kHz, Fe{sup 2+}/H{sub 2}O{sub 2} 0.05 mol/mol, pH 2.10 in aqueous phase and reaction time 15 min, the sulfur content in the diesel fuels was decreased from 568.75 {mu}g/g to 9.50 {mu}g/g. (author)

  4. Proof-of-Concept Study: Novel Microbially-Driven Fenton Reaction for In Situ Remediation of Groundwater Contaminated with 1,4-Dioxane, Tetrachloroethene (PCE) and Trichloroethene (TCE)

    Science.gov (United States)

    2014-09-17

    with 1,4-Dioxane, Tetrachloroethene (PCE) and Trichloroethene ( TCE ) SERDP Project ER-2305 September 2014 Thomas DiChristina Georgia...HO) radicals that degrade 1,4- dioxane, TCE , and PCE. In comparison to conventional (purely abiotic) Fenton reactions, the microbially-driven Fenton...reaction operates at circumneutral pH and does not require addition of exogenous H2O2 or UV irradiation to regenerate Fe(II). The 1,4-dioxane, TCE

  5. Facile preparation of magnetic mesoporous Fe{sub 3}O{sub 4}/C/Cu composites as high performance Fenton-like catalysts

    Energy Technology Data Exchange (ETDEWEB)

    Li, Keyan; Zhao, Yongqin [State Key Laboratory of Fine Chemicals, PSU-DUT Joint Center for Energy Research, School of Chemical Engineering, Dalian University of Technology, Dalian 116024 (China); Janik, Michael J. [Department of Chemical Engineering, The Pennsylvania State University, University Park, PA 16802 (United States); Song, Chunshan [State Key Laboratory of Fine Chemicals, PSU-DUT Joint Center for Energy Research, School of Chemical Engineering, Dalian University of Technology, Dalian 116024 (China); EMS Energy Institute, PSU-DUT Joint Center for Energy Research and Department of Energy & Mineral Engineering, The Pennsylvania State University, University Park, PA 16802 (United States); Guo, Xinwen, E-mail: guoxw@dlut.edu.cn [State Key Laboratory of Fine Chemicals, PSU-DUT Joint Center for Energy Research, School of Chemical Engineering, Dalian University of Technology, Dalian 116024 (China)

    2017-02-28

    Highlights: • Fe-Cu composites with different compositions were prepared by calcining tartrates. • Magnetic mesoporous Fe{sub 3}O{sub 4}/C/Cu was obtained by calcining tartrate under N{sub 2}. • Fe{sub 3}O{sub 4}/C/Cu exhibits excellent photo-Fenton catalytic activity and reusability. • The activity is due to the synergistic and photo-reduction effects of Fe and Cu. - Abstract: Fe-Cu composites with different compositions and morphologies were synthesized by a hydrothermal method combined with precursor thermal transformation. γ-Fe{sub 2}O{sub 3}/CuO and α-Fe{sub 2}O{sub 3}/CuO were obtained by calcining the Fe and Cu tartrates under air atmosphere at 350 °C and 500 °C, respectively, while Fe{sub 3}O{sub 4}/C/Cu was obtained by calcining the tartrate precursor under N{sub 2} atmosphere at 500 °C. The Fe{sub 3}O{sub 4}/C/Cu composite possessed mesoporous structure and large surface area up to 133 m{sup 2} g{sup −1}. The Fenton catalytic performance of Fe{sub 3}O{sub 4}/C/Cu composite was closely related to the Fe/Cu molar ratio, and only proper amounts of Fe and Cu exhibited a synergistic enhancement in Fenton catalytic activity. Cu inclusion reduced Fe{sup 3+} to Fe{sup 2+}, which accelerated the Fe{sup 3+}/Fe{sup 2+} cycles and favored H{sub 2}O{sub 2} decomposition to produce more hydroxyl radicals for methylene blue (MB) oxidation. Due to the photo-reduction of Fe{sup 3+} and Cu{sup 2+}, the Fenton catalytic performance was greatly improved when amending with visible light irradiation in the Fe{sub 3}O{sub 4}/C/Cu-H{sub 2}O{sub 2} system, and MB (100 mg L{sup −1}) was nearly removed within 60 min. The Fe{sub 3}O{sub 4}/C/Cu composite showed good recyclability and could be conveniently separated by an applied magnetic field. Compared with conventional methods for mesoporous composite construction, the thermolysis method using mixed metal tartrates as precursors has the advantages of easy preparation and low cost. This strategy provides a facile

  6. Audio-magnetotelluric (AMT) study to investigate the genesis of Mujil hill

    Science.gov (United States)

    Rahmania, Suryanto, Wiwit

    2017-07-01

    Gunung Mujil is an isolated hill located near Pondoworejo village, Kalibawang sub-district, Kulon Progo district, and Special Province of Yogyakarta. The hill is part of the eastern Kulon Progo mountain range extended relatively in the North-South direction. The lithology of the hill consists of andesite breccia and it's similar with the Old Andesite Formation that built the Kulon Progo Mountains. There are at least two hypothesis about the genesis and the formation mechanism of this hill, (1) it was formed by debris mass from Kulon Progo Mountains, and (2) ) it was formed by an intrusion. Our study intended to determine the subsurface resistivity below the hill and to relating those results to with the scenario of the genesis of the Mujil hill. We conducted Audio-magnetotellurics (AMT) measurements along two lines survey crossing the Mujil hill consisting of 20 measurements. Since the measurements are located near the villages, most of the data has a fair to bad quality and only one station yielded an excellent data. A 1D Forward modeling was then applied to find best-fit model of the AMT data. The results shows that the Mujil hill was built by debris mass of the Old Andesite Formation from Kulon Progo mountain which is represented by a lower resistivity value under the Mujil hill.

  7. Fenton degradation of Cartap hydrochloride: identification of the main intermediates and the degradation pathway.

    Science.gov (United States)

    Tian, Kaixun; Ming, Cuixiang; Dai, Youzhi; Honore Ake, Kouassi Marius

    2015-01-01

    The advanced oxidation of Cartap hydrochloride (Cartap) promoted by the Fenton system in an aqueous medium was investigated. Based on total organic carbon, chemical oxygen demand and high-performance liquid chromatography, the oxidation of Cartap is quite efficient by the Fenton system. Its long chain is easily destroyed, but the reaction does not proceed to complete mineralization. Ion chromatography detection indicated the formation of acetic acid, propionic acid, formic acid, nitrous acid and sulfuric acid in the reaction mixtures. Further evidence of nitrogen monoxide and sulfur dioxide formation was obtained by using a flue gas analyzer. Monitoring by gas chromatograph-mass spectrometer demonstrated the formation of oxalic acid, ethanol, carbon dioxide, and L-alanine ethylamide. Based on these experimental results, plausible degradation pathways for Cartap mineralization in an aqueous medium by the Fenton system are proposed.

  8. Funny hills in pion spectra from heavy-ion collisions

    International Nuclear Information System (INIS)

    Rasmussen, J.O.

    1982-03-01

    A discussion of some of the systematic features of the pion spectra in heavy-ions reactions is given. A discussion of the hills and valleys in heavy ion pion spectra that show up at the lower pion energies is given. The following topics are discussed: (1) three kinds of funny hills; (2) π - / + ratios near center of mass; (3) new Monte Carlo studies of charged pion spectra; and (4) pion orbiting about fireballs and Bose-Einstein behavior as explanation for the mid-rapidity P/sub perpendicular to/ approx. = 0.4 to 0.5 m/sub π/c hill

  9. Coupling between high-frequency ultrasound and solar photo-Fenton at pilot scale for the treatment of organic contaminants: an initial approach.

    Science.gov (United States)

    Papoutsakis, Stefanos; Miralles-Cuevas, Sara; Gondrexon, Nicolas; Baup, Stéphane; Malato, Sixto; Pulgarin, César

    2015-01-01

    This study aims to evaluate the performance of a novel pilot-scale coupled system consisting of a high frequency ultrasonic reactor (400kHz) and a compound parabolic collector (CPC). The benefits of the concurrent application of ultrasound and the photo-Fenton process were studied in regard to the degradation behavior of a series of organic pollutants. Three compounds (phenol, bisphenol A and diuron) with different physicochemical properties have been chosen in order to identify possible synergistic effects and to obtain a better estimate of the general feasibility of such a system at field scale (10L). Bisphenol A and diuron were specifically chosen due to their high hydrophobicity, and thus their assumed higher affinity towards the cavitation bubble. Experiments were conducted under ultrasonic, photo-Fenton and combined treatments. Enhanced degradation kinetics were observed during the coupled treatment and synergy factors clearly in excess of 1 have been calculated for phenol as well as for saturated solutions of bisphenol A and diuron. Although the relatively high cost of ultrasound compared to photo-Fenton still presents a significant challenge towards mainstream industrial application, the observed behavior suggests that its prudent use has the potential to significantly benefit the photo-Fenton process, via the decrease of both treatment time and H2O2 consumption. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Photoassisted Fenton degradation of phthalocyanine dyes from wastewater of printing industry using Fe(II)/γ-Al2O3 catalyst in up-flow fluidized-bed.

    Science.gov (United States)

    Cheng, Hsuhui; Chou, Shihjie; Chen, Shiaoshing; Yu, Chiajen

    2014-06-01

    Fe(II)/γ-Al2O3 powders synthesized using the dipping method were produced from a mixed aqueous solution containing aluminium oxide (γ-Al2O3) and iron(II)-precursor (FeSO4), and used for photo-Fenton degradation of phthalocyanine dyes (PCS) under ultraviolet (UV) irradiation in an up-flow fluidized bed. The catalysts were characterized by XRD, ESCA, BET, EDS and SEM. The results showed that Fe(2+) ion was compounded on the γ-Al2O3 carrier. The effects of different reaction parameters such as catalyst activity, dosage and solution pH on the decolorization of PCS were assessed. Results indicated that maximum decolorization (more than 95%) of PCS occurred with 20 wt% Fe(II)/γ-Al2O3 catalyst (dosage of 60 g/L) using a combination of UV irradiation and heterogeneous Fenton system. The degradation efficiency of PCS increases as pH decreases, exhibiting a maximum efficiency at pH 3.5. The recycled catalyst was capable of repeating three runs without a significant decrease in treatment efficiency, and this demonstrated the stability and reusability of catalyst. Copyright © 2014 The Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences. Published by Elsevier B.V. All rights reserved.

  11. Decolourization of methyl orange using iron- immobilize MKSF in UV assisted Fenton-like reaction

    Science.gov (United States)

    Abdullah, N. H.; Zubir, N. A.; Hassan, H.

    2017-09-01

    In this work, montmorillonite KSF clay was used to immobilize iron species as a potential heterogeneous UV assisted Fenton-like reaction. Iron-immobilized MKSF (Fe-MKSF) was synthesized via hydrothermal method in an autoclave. Fe-MKSF was tested on methyl orange (MO) removal by adsorption (5%) and hydrogen peroxide (H2O2) activation (63%) and these prominent margins proved Fe-MKSF performance was attributed by UV assisted Fenton-like reaction. Fe-MKSF show superior performance with 63% color removal within 180 mins reaction in comparison to iron oxide and pristine MKSF. The Fe-MKSF increased in the surface area from 91.1 to 101.9 m2/g and pore volume from 0.13 to 0.45 cm3/g compared to pristine MKSF. The SEM images of Fe-MKSF show iron aggregates indicating successful immobilizing process and the elemental weight percent of iron which increase from 6.12% to 55.38% in Fe-MKSF. These findings prove Fe-MKSF as a promising alternative catalyst in dye contaminated wastewater treatment.

  12. UV/Fenton photo-oxidation of Drimarene Dark Red (DDR) containing textile-dye wastewater

    Science.gov (United States)

    Hudaya, T.; Anthonios, J.; Septianto, E.

    2016-11-01

    Textile dye wastewater contains organic pollutants which are non-biodegradable, characterized by low BOD/COD ratio of typically Advanced Oxidation Processes (AOPs). One of the AOPs method which is the UV/H2O2/Fe2+ (or UV/Fenton) offers not only relatively low cost but also quite effective (in terms of color removal and reaction time) treatment. This particular research aimed to optimize the conditions of UV/Fenton photo-oxidation process for Drimarene Dark Red containing textile- dye wastewater. The two main operating conditions to be optimized were the initial concentration of H2O2 ranged between 0.022-0.078 %-w and the mol ratio of Fe2+: H2O2 was varied from 1: 13 up to 1: 45, using the Central Composite Design experimental matrix. The photo-oxidation was carried out at the optimum pH of 3 from some previous experiments. The best processing conditions of the photo-oxidation of Drimarene Dark Red (DDR) were found at the initial concentration of H2O2 at 0.050%-w and the mole ratio Fe2+: H2O2 of 1: 22. Under these conditions, the measured 2nd order pseudo-rate constantwas 0.021 M-1.min-1. The DDR color removal of 90% was surprisingly achievable within only 10 minutes reaction time.

  13. How does intensification influence the operational and environmental performance of photo-Fenton processes at acidic and circumneutral pH.

    Science.gov (United States)

    Salazar, Luis Miguel; Grisales, Claudia Mildred; Garcia, Dorian Prato

    2018-05-31

    This study evaluates the technical, economical, and environmental impact of sodium persulfate (Na 2 S 2 O 8 ) as an enhancing agent in a photo-Fenton process within a solar-pond type reactor (SPR). Photo-Fenton (PF) and photo-Fenton intensified with the addition of persulfate (PFPS) processes decolorize 97% the azo dye direct blue 71 (DB71) and allow producing a highly biodegradable effluent. Intensification with persulfate allowed reducing treatment time in 33% (from 120 to 80 min) and the consumption of chemical auxiliaries needed for pH adjustment. Energy, reagents, and chemical auxiliaries are still and environmental hotspot for PF and PFPS; however, it is worth mentioning that their environmental footprint is lower than that observed for compound parabolic concentrator (CPC)-type reactors. A life-cycle assessment (LCA) confirms that H 2 O 2 , NaOH, and energy consumption are the variables with the highest impact from an environmental standpoint. The use of persulfate reduced the relative impact in 1.2 to 12% in 12 of the 18 environmental categories studied using the ReCiPe method. The PFPS process emits 1.23 kg CO 2 (CO 2 -Eqv/m 3 treated water). On the other hand, the PF process emits 1.28 kg CO 2 (CO 2 -Eqv/m 3 treated water). Process intensification, chemometric techniques, and the use of SPRs minimize the impact of some barriers (reagent and energy consumption, technical complexity of reactors, pressure drops, dirt on the reflecting surfaces, fragility of reactor materials), limiting the application of advanced oxidation systems at an industrial level, and decrease treatment cost as well as potential environmental impacts associated with energy and reagents consumption. Treatment costs for PF processes (US$0.78/m 3 ) and PFPS processes (US$0.63/m 3 ) were 20 times lower than those reported for photo-Fenton processes in CPC-type reactors.

  14. Rotary nickel-titanium GT and ProTaper files for root canal shaping by novice operators: a radiographic and micro-computed tomography evaluation.

    Science.gov (United States)

    Gekelman, Diana; Ramamurthy, Ramya; Mirfarsi, Sahar; Paqué, Frank; Peters, Ove A

    2009-11-01

    The purpose of this study was to assess canal preparation outcomes in vitro by novice clinicians after standardized teaching sessions. All students received a training session. In experiment 1, twenty canals of mandibular molars were prepared with GT and ProTaper rotaries by 10 students. Standardized radiographs were exposed before and after canal preparation, and canal curvature was measured; canals were assessed for patency and preparation time. In experiment 2, mandibular molars (20 canals) were submitted to microcomputed tomography before and after canal preparation with ProTaper and GT rotaries by 2 dental students. Canals were metrically assessed for changes (volume, surface, cross-sectional shape, transportation) during canal preparation by using software. In experiment 1, canal curvature decreased by 7.6 degrees and 7.8 degrees for GT and ProTaper preparations; there were no broken instruments, and 2 canals lost patency. The time for GT preparation was longer than for ProTaper (29.7 +/- 6.8 vs 19.4 +/- 8.1 minutes, P session.

  15. Fenton reaction induced cancer in wild type rats recapitulates genomic alterations observed in human cancer.

    Directory of Open Access Journals (Sweden)

    Shinya Akatsuka

    Full Text Available Iron overload has been associated with carcinogenesis in humans. Intraperitoneal administration of ferric nitrilotriacetate initiates a Fenton reaction in renal proximal tubules of rodents that ultimately leads to a high incidence of renal cell carcinoma (RCC after repeated treatments. We performed high-resolution microarray comparative genomic hybridization to identify characteristics in the genomic profiles of this oxidative stress-induced rat RCCs. The results revealed extensive large-scale genomic alterations with a preference for deletions. Deletions and amplifications were numerous and sometimes fragmented, demonstrating that a Fenton reaction is a cause of such genomic alterations in vivo. Frequency plotting indicated that two of the most commonly altered loci corresponded to a Cdkn2a/2b deletion and a Met amplification. Tumor sizes were proportionally associated with Met expression and/or amplification, and clustering analysis confirmed our results. Furthermore, we developed a procedure to compare whole genomic patterns of the copy number alterations among different species based on chromosomal syntenic relationship. Patterns of the rat RCCs showed the strongest similarity to the human RCCs among five types of human cancers, followed by human malignant mesothelioma, an iron overload-associated cancer. Therefore, an iron-dependent Fenton chemical reaction causes large-scale genomic alterations during carcinogenesis, which may result in distinct genomic profiles. Based on the characteristics of extensive genome alterations in human cancer, our results suggest that this chemical reaction may play a major role during human carcinogenesis.

  16. IMPACT D’UN AGENT COMPLEXANT DU FER DANS LE PROCEDE DE PHOTO-FENTON SUR LA DEGRADATION DU 3-METHYLPHENOL EN PHASE HOMOGENE

    Directory of Open Access Journals (Sweden)

    Nassira SERAGHNI

    2017-12-01

    Full Text Available In this study we used 3-methylphenol (3MP as a pollutant model of phenols to study the effectiveness of the photo-Fenton Fe(IIIOx system. The preliminary study of the mixture 3MP-Fe(IIIOx-H2O2 in the absence of light and at room temperature allowed us to confirm the absence of interaction under our experimental conditions. However, the same system was studied in the presence of light (365 nm in order to study the photo-Fenton process. Various parameters (H2O2 concentrations and pH were tested in order to optimize the efficiency of the system in terms of degradation of 3MP. In order to understand the mechanism involved in radical inhibition experiments (•OH and HO2• / O2•- have been carried out. One of the important conclusions of this work is that the Fe(IIIOx complex plays a very positive role in the degradation of 3MP. In addition, we have also shown that this process is very efficient in the neutral pH range. This complex is really a very promising source of iron in the photo-Fenton processes.

  17. Removal of trace metals and improvement of dredged sediment dewaterability by bioleaching combined with Fenton-like reaction.

    Science.gov (United States)

    Zeng, Xiangfeng; Twardowska, Irena; Wei, Shuhe; Sun, Lina; Wang, Jun; Zhu, Jianyu; Cai, Jianchao

    2015-05-15

    Bioleaching by Aspergillus niger strain SY1 combined with Fenton-like reaction was optimized to improve trace metal removal and dewaterability of dredged sediments. The major optimized parameters were the duration of bioleaching and H₂O₂ dose in Fenton-like process (5 days and 2g H₂O₂/L, respectively). Bioleaching resulted in the removal of ≈90% of Cd, ≈60% of Zn and Cu, ≈20% of Pb, and in decrease of sediment pH from 6.6 to 2.5 due to organic acids produced by A. niger. After addition of H₂O₂, Fenton-like reaction was initiated and further metal removal occurred. Overall efficiency of the combined process comprised: (i) reduction of Cd content in sediment by 99.5%, Cu and Zn by >70% and Pb by 39% as a result of metal release bound in all mobilizable fractions; (ii) decrease of sediment capillary suction time (CST) from 98.2s to 10.1s (by 89.8%) and specific resistance to filtration (SRF) from 37.4×10(12)m/kg to 6.2×10(12)m/kg (by 83.8%), due to reducing amount of extracellular polymeric substances (EPS) by 68.7% and bound water content by 79.1%. The combined process was found to be an efficient method to remove trace metals and improve dewaterability of contaminated dredged sediments. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Treatment of municipal wastewater treatment plant effluents with modified photo-Fenton as a tertiary treatment for the degradation of micro pollutants and disinfection.

    Science.gov (United States)

    Klamerth, Nikolaus; Malato, Sixto; Agüera, Ana; Fernández-Alba, Amadeo; Mailhot, Gilles

    2012-03-06

    The goal of this paper was to develop a modified photo-Fenton treatment able to degrade micro pollutants in municipal wastewater treatment plant (MWTP) effluents at a neutral pH with minimal iron and H(2)O(2) concentrations. Complexation of Fe by ethylenediamine-N,N'-disuccinic acid (EDDS) leads to stabilization and solubilization of Fe at natural pH. Photo-Fenton experiments were performed in a pilot compound parabolic collector (CPC) solar plant. Samples were treated with solid phase extraction (SPE) and analyzed by HPLC-Qtrap-MS. The rapid degradation of contaminants within the first minutes of illumination and the low detrimental impact on degradation of bicarbonates present in the water suggested that radical species other than HO(•) are responsible for the efficiency of such photo-Fenton process. Disinfection of MWTP effluents by the same process showed promising results, although disinfection was not complete.

  19. Utilization of waste heat from GT-MHR for power generation in organic Rankine cycles

    International Nuclear Information System (INIS)

    Yari, Mortaza; Mahmoudi, S.M.S.

    2010-01-01

    The gas turbine-modular helium reactor (GT-MHR) is currently being developed by an international consortium. In this power plant, circulating helium that has to be compressed in a single or two successive stages cools the reactor core. For thermodynamic reasons, these compression stages require pre-cooling of the helium to about 26 deg. C through the use of intercooler and pre-cooler in which water is used to cool the helium. Considerable thermal energy (∼300 MWth) is thus dissipated in these components. This thermal energy is then rejected to a heat sink. For different designs, the temperature ranges of the helium in the intercooler and pre-cooler could be about 100 and 150 deg. C, respectively. These are ideal energy sources to be used in an organic Rankine cycles for power generation. This study examines the performance of a gas-cooled nuclear power plant with closed Brayton cycle (CBC) combined with two organic Rankine cycles (ORC). More attention was paid to the irreversibilities generated in the combined cycle. Individual models are developed for each component through applications of the first and second laws of thermodynamics. The effects of the turbine inlet temperature, compressor pressure ratio, evaporator temperature and temperature difference in the evaporator on the first- and second-law efficiencies and on the exergy destruction rate of the combined cycle were studied. Finally the combined cycle was optimized thermodynamically using the EES (Engineering Equation Solver) software. Based on identical operating conditions, a comparison between the GT-MHR/ORC and a simple GT-MHR cycle is also made. It was found that both the first- and second-law efficiencies of GT-MHR/ORC cycle are about 3%-points higher than that of the simple GT-MHR cycle. Also, the exergy destruction rate for GT-MHR/ORC cycle is about 5% lower than that of the GT-MHR cycle.

  20. Advanced landfill leachate treatment using iron-carbon microelectrolysis- Fenton process: Process optimization and column experiments

    International Nuclear Information System (INIS)

    Wang, Liqun; Yang, Qi; Wang, Dongbo; Li, Xiaoming; Zeng, Guangming; Li, Zhijun; Deng, Yongchao; Liu, Jun; Yi, Kaixin

    2016-01-01

    Highlights: • Fe-C microelectrolysis-Fenton process is proposed to pretreat landfill leachate. • Operating variables are optimized by response surface methodology (RSM). • 3D-EEMs and MW distribution explain the mechanism of enhanced biodegradability. • Fixed-bed column experiments are performed at different flow rates. - Abstract: A novel hydrogen peroxide-enhanced iron-carbon (Fe-C) microelectrolysis reactor was proposed for the pretreatment of mature landfill leachate. This reactor, combining microelectrolysis with Fenton process, revealed high treatment efficiency. The operating variables, including Fe-C dosage, H_2O_2 concentration and initial pH, were optimized by the response surface methodology (RSM), regarding the chemical oxygen demand (COD) removal efficiency and biochemical oxygen demand: chemical oxygen demand (BOD_5/COD) as the responses. The highest COD removal (74.59%) and BOD_5/COD (0.50) was obtained at optimal conditions of Fe-C dosage 55.72 g/L, H_2O_2 concentration 12.32 mL/L and initial pH 3.12. Three-dimensional excitation and emission matrix (3D-EEM) fluorescence spectroscopy and molecular weight (MW) distribution demonstrated that high molecular weight fractions such as refractory fulvic-like substances in leachate were effectively destroyed during the combined processes, which should be attributed to the combination oxidative effect of microelectrolysis and Fenton. The fixed-bed column experiments were performed and the breakthrough curves at different flow rates were evaluated to determine the practical applicability of the combined process. All these results show that the hydrogen peroxide-enhanced iron-carbon (Fe-C) microelectrolysis reactor is a promising and efficient technology for the treatment of mature landfill leachate.

  1. Advanced landfill leachate treatment using iron-carbon microelectrolysis- Fenton process: Process optimization and column experiments

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Liqun, E-mail: 691127317@qq.com [College of Environmental Science and Engineering, Hunan University, Changsha 410082 (China); Key Laboratory of Environmental Biology and Pollution Control (Hunan University), Ministry of Education, Changsha 410082 (China); Yang, Qi, E-mail: yangqi@hnu.edu.cn [College of Environmental Science and Engineering, Hunan University, Changsha 410082 (China); Key Laboratory of Environmental Biology and Pollution Control (Hunan University), Ministry of Education, Changsha 410082 (China); Wang, Dongbo [College of Environmental Science and Engineering, Hunan University, Changsha 410082 (China); Key Laboratory of Environmental Biology and Pollution Control (Hunan University), Ministry of Education, Changsha 410082 (China); Li, Xiaoming, E-mail: xmli121x@hotmail.com [College of Environmental Science and Engineering, Hunan University, Changsha 410082 (China); Key Laboratory of Environmental Biology and Pollution Control (Hunan University), Ministry of Education, Changsha 410082 (China); Zeng, Guangming; Li, Zhijun; Deng, Yongchao; Liu, Jun; Yi, Kaixin [College of Environmental Science and Engineering, Hunan University, Changsha 410082 (China); Key Laboratory of Environmental Biology and Pollution Control (Hunan University), Ministry of Education, Changsha 410082 (China)

    2016-11-15

    Highlights: • Fe-C microelectrolysis-Fenton process is proposed to pretreat landfill leachate. • Operating variables are optimized by response surface methodology (RSM). • 3D-EEMs and MW distribution explain the mechanism of enhanced biodegradability. • Fixed-bed column experiments are performed at different flow rates. - Abstract: A novel hydrogen peroxide-enhanced iron-carbon (Fe-C) microelectrolysis reactor was proposed for the pretreatment of mature landfill leachate. This reactor, combining microelectrolysis with Fenton process, revealed high treatment efficiency. The operating variables, including Fe-C dosage, H{sub 2}O{sub 2} concentration and initial pH, were optimized by the response surface methodology (RSM), regarding the chemical oxygen demand (COD) removal efficiency and biochemical oxygen demand: chemical oxygen demand (BOD{sub 5}/COD) as the responses. The highest COD removal (74.59%) and BOD{sub 5}/COD (0.50) was obtained at optimal conditions of Fe-C dosage 55.72 g/L, H{sub 2}O{sub 2} concentration 12.32 mL/L and initial pH 3.12. Three-dimensional excitation and emission matrix (3D-EEM) fluorescence spectroscopy and molecular weight (MW) distribution demonstrated that high molecular weight fractions such as refractory fulvic-like substances in leachate were effectively destroyed during the combined processes, which should be attributed to the combination oxidative effect of microelectrolysis and Fenton. The fixed-bed column experiments were performed and the breakthrough curves at different flow rates were evaluated to determine the practical applicability of the combined process. All these results show that the hydrogen peroxide-enhanced iron-carbon (Fe-C) microelectrolysis reactor is a promising and efficient technology for the treatment of mature landfill leachate.

  2. Fertility in Hill Korwas -- a primitive tribe of Madhya Pradesh.

    Science.gov (United States)

    Pandey, G D; Tiwary, R S

    1996-12-01

    This study examines fertility behavior among 604 eligible couples in Hill Korwa tribes in Madhya Pradesh state, India. Low fertility patterns are compared to those of neighboring Gonds and nontribals from rural Jabalpur. The Hill Korwa are a subtribe of the Korwa, who remained in the hills and dense forests. Over 60% live in three tehsils of Surguja district, including Ambikapur tehsil where the study was conducted. Data were obtained in March 1991. Eligible couples were those where both partners live together and the noncontracepting wife is under age 50 and nonmenopausal. Only 3% were literate. Female marriage age was about 15 years. The median age was 23.8 years. 92% lived below the poverty line. The average number of children ever born (CEB) per couple was 1.9, compared to 2.5 for the Gond and 2.9 for nontribal couples. The CEB in a reproductive lifetime was 2.9, compared to 5.3 for Gond women and 5.9 for nontribal women. Fecundity among Hill Korwa women was 66% lower at younger ages (16-17 years and 17-18 years), and the differences increased with an increase in age at marriage. Hill Korwas had a low female age at marriage, low literacy, low percentages engaged in agriculture, and higher percentages living above the poverty line.

  3. Integration of processes induced air flotation and photo-Fenton for treatment of residual waters contaminated with xylene

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Syllos S. da [Departamento Engenharia Quimica, NUPEG, Universidade Federal do Rio Grande do Norte, Campus Universitario, Lagoa Nova, Natal 59066-800, RN (Brazil); Chiavone-Filho, Osvaldo, E-mail: osvaldo@eq.ufrn.br [Departamento Engenharia Quimica, NUPEG, Universidade Federal do Rio Grande do Norte, Campus Universitario, Lagoa Nova, Natal 59066-800, RN (Brazil); Barros Neto, Eduardo L. de [Departamento Engenharia Quimica, NUPEG, Universidade Federal do Rio Grande do Norte, Campus Universitario, Lagoa Nova, Natal 59066-800, RN (Brazil); Nascimento, Claudio A.O. [Departamento de Engenharia Quimica, Escola Politecnica, Universidade de Sao Paulo, Cidade Universitaria, Sao Paulo 05508-900, SP (Brazil)

    2012-01-15

    Highlights: Black-Right-Pointing-Pointer We have studied the treatment of wastewater contaminated with hydrocarbons represented by the xylene, using these processes in an integrated mode: induced air flotation and photo-Fenton. Black-Right-Pointing-Pointer We have selected xylene as representative contaminant due to properties of toxicity, solubility in water and vapor pressure. Black-Right-Pointing-Pointer The manuscript presents a series of accurate experimental data that can be useful for material and energy optimization purposes in the xylene removal aiming the treatment of oil field produced water. - Abstract: Produced water in oil fields is one of the main sources of wastewater generated in the industry. It contains several organic compounds, such as benzene, toluene, ethyl benzene and xylene (BTEX), whose disposal is regulated by law. The aim of this study is to investigate a treatment of produced water integrating two processes, i.e., induced air flotation (IAF) and photo-Fenton. The experiments were conducted in a column flotation and annular lamp reactor for flotation and photodegradation steps, respectively. The first order kinetic constant of IAF for the wastewater studied was determined to be 0.1765 min{sup -1} for the surfactant EO 7. Degradation efficiencies of organic loading were assessed using factorial planning. Statistical data analysis shows that H{sub 2}O{sub 2} concentration is a determining factor in process efficiency. Degradations above 90% were reached in all cases after 90 min of reaction, attaining 100% mineralization in the optimized concentrations of Fenton reagents. Process integration was adequate with 100% organic load removal in 20 min. The results of the integration of the IAF with the photo-Fenton allowed to meet the effluent limits established by Brazilian legislation for disposal.

  4. Removal of residual contaminants in petroleum-contaminated soil by Fenton-like oxidation

    Energy Technology Data Exchange (ETDEWEB)

    Lu Mang [School of Material Science and Engineering, Jingdezhen Ceramic Institute, Jingdezhen, 333001, Jiangxi Province (China); State Key Laboratory of Heavy Oil Processing, China University of Petroleum, Beijing 102249 (China); Zhang Zhongzhi, E-mail: zzzhang1955@hotmail.com [State Key Laboratory of Heavy Oil Processing, China University of Petroleum, Beijing 102249 (China); Qiao Wei; Guan Yueming; Xiao Meng; Peng Chong [State Key Laboratory of Heavy Oil Processing, China University of Petroleum, Beijing 102249 (China)

    2010-07-15

    The degradation of bioremediation residues by hydrogen peroxide in petroleum-contaminated soil was investigated at circumneutral pH using a Fenton-like reagent (ferric ion chelated with EDTA). Batch tests were done on 20 g soil suspended in 60 mL aqueous solution containing hydrogen peroxide and Fe{sup 3+}-EDTA complex under constant stirring. A slurry reactor was used to treat the soil based on the optimal reactant conditions. Contaminants were characterized by Fourier transform infrared spectroscopy and Fourier transform ion cyclotron resonance mass spectrometry. The results showed that the optimal treatment condition was: the molar ratio of hydrogen peroxide to iron = 200:1, and pH 7.0. Under the optimum condition, total dichloromethane-extractable organics were reduced from 14,800 to 2300 mg kg{sup -1} soil when the accumulative H{sub 2}O{sub 2} dosage was 2.45 mol kg{sup -1} soil during the reactor treatment. Abundance of viable cells was lower in incubated Fenton-like treated soil than in untreated soil. Oxidation of contaminants produced remarkable compositional and structural modifications. A fused ring compound, identified as C{sub 34}H{sub 38}N{sub 1}, was found to exhibit the greatest resistance to oxidation.

  5. Aberrant ERK 1/2 complex activation and localization in scrapie-infected GT1-1 cells

    Directory of Open Access Journals (Sweden)

    Didonna Alessandro

    2010-08-01

    Full Text Available Abstract Background Fatal neurodegenerative disorders such as Creutzfeldt-Jakob and Gerstmann-Sträussler-Scheinker diseases in humans, scrapie and bovine spongiform encephalopathy in animals, are characterized by the accumulation in the brain of a pathological form of the prion protein (PrP denominated PrPSc. The latter derives from the host cellular form, PrPC, through a process whereby portions of its α-helical and coil structures are refolded into β-sheet structures. Results In this work, the widely known in vitro model of prion replication, hypothalamic GT1-1 cell line, was used to investigate cellular and molecular responses to prion infection. The MAP kinase cascade was dissected to assess the phosphorylation levels of src, MEK 1/2 and ERK 1/2 signaling molecules, both before and after prion infection. Our findings suggest that prion replication leads to a hyper-activation of this pathway. Biochemical analysis was complemented with immunofluorescence studies to map the localization of the ERK complex within the different cellular compartments. We showed how the ERK complex relocates in the cytosol upon prion infection. We correlated these findings with an impairment of cell growth in prion-infected GT1-1 cells as probed by MTT assay. Furthermore, given the persistent urgency in finding compounds able to cure prion infected cells, we tested the effects on the ERK cascade of two molecules known to block prion replication in vitro, quinacrine and Fab D18. We were able to show that while these two compounds possess similar effects in curing prion infection, they affect the MAP kinase cascade differently. Conclusions Taken together, our results help shed light on the molecular events involved in neurodegeneration and neuronal loss in prion infection and replication. In particular, the combination of chronic activation and aberrant localization of the ERK complex may lead to a lack of essential neuroprotective and survival factors

  6. Reduction of clarithromycin and sulfamethoxazole-resistant Enterococcus by pilot-scale solar-driven Fenton oxidation.

    Science.gov (United States)

    Karaolia, Popi; Michael, Irene; García-Fernández, Irene; Agüera, Ana; Malato, Sixto; Fernández-Ibáñez, Pilar; Fatta-Kassinos, Despo

    2014-01-15

    The presence of pathogenic antibiotic-resistant bacteria in aquatic environments has become a health threat in the last few years. Their presence has increased due to the presence of antibiotics in wastewater effluents, which are not efficiently removed by conventional wastewater treatments. As a result there is a need to study the possible ways of removal of the mixtures of antibiotics present in wastewater effluents and the antibiotic-resistant bacteria, which may also spread the antibiotic resistance genes to other bacterial populations. In this study the degradation of a mixture of antibiotics i.e. sulfamethoxazole and clarithromycin, the disinfection of total enterococci and the removal of those resistant to: a) sulfamethoxazole, b) clarithromycin and c) to both antibiotics have been examined, along with the toxicity of the whole effluent mixture after treatment to the luminescent aquatic bacterium Vibrio fischeri. Solar Fenton treatment (natural solar driven oxidation) using Fenton reagent doses of 50 mg L(-1) of hydrogen peroxide and 5 mg L(-1) of Fe(3+) in a pilot-scale compound parabolic collector plant was used to examine the disinfection and antibiotic resistance removal efficiency in different aqueous matrices, namely distilled water, simulated and real wastewater effluents. There was a faster complete removal of enterococci and of antibiotics in all aqueous matrices by applying solar Fenton when compared to photolytic treatment of the matrices. Sulfamethoxazole was more efficiently degraded than clarithromycin in all three aqueous matrices (95% removal of sulfamethoxazole and 70% removal of clarithromycin in real wastewater). The antibiotic resistance of enterococci towards both antibiotics exhibited a 5-log reduction with solar Fenton in real wastewater effluent. Also after solar Fenton treatment, there were 10 times more antibiotic-resistant enterococci in the presence of sulfamethoxazole than in the presence of clarithromycin. Finally, the toxicity

  7. Enhanced Fenton-like degradation of TCE in sand suspensions with magnetite by NTA/EDTA at circumneutral pH.

    Science.gov (United States)

    Wang, Na; Jia, Daqing; Jin, Yaoyao; Sun, Sheng-Peng; Ke, Qiang

    2017-07-01

    The present study investigated the degradation of trichloroethylene (TCE) in sand suspensions by Fenton-like reaction with magnetite (Fe 3 O 4 ) in the presence of various chelators at circumneutral pH. The results showed that ethylenediaminetetraacetic acid (EDTA) and nitrilotriacetic acid (NTA) greatly improved the rate of TCE degradation, while [S,S]-ethylenediaminedisuccinic acid (s,s-EDDS), malonate, citrate, and phytic acid (IP6) have minimal effects on TCE degradation. Quenching tests suggested that TCE was mainly degraded by hydroxyl radical (HO · ) attack, with about 90% inhibition on TCE degradation by the addition of HO · scavenger 2-propanol. The presence of 0.1-0.5% Fe 3 O 4 /sand (w/w) contributed to 40% increase in TCE degradation rates. In particular, the use of chelators can avoid high concentrations of H 2 O 2 required for the Fenton-like reaction with Fe 3 O 4 , and moreover improve the stoichiometric efficiencies of TCE degradation to H 2 O 2 consumption. The suitable concentrations of chelators (EDTA and NTA) and H 2 O 2 were suggested to be 0.5 and 20 mM, respectively. Under the given conditions, degradation rate constants of TCE were obtained at 0.360 h -1 with EDTA and 0.526 h -1 with NTA, respectively. Enhanced degradation of TCE and decreased usage of H 2 O 2 in this investigation suggested that Fenton-like reaction of Fe 3 O 4 together with NTA (or EDTA) may be a promising process for remediation of TCE-contaminated groundwater.

  8. Fenton mediated ultrasonic disintegration of sludge biomass: Biodegradability studies, energetic assessment, and its economic viability.

    Science.gov (United States)

    Kavitha, S; Rajesh Banu, J; IvinShaju, C D; Kaliappan, S; Yeom, Ick Tae

    2016-12-01

    Mechanical disintegration of sludge through ultrasonication demands high energy and cost. Therefore, in the present study, a comprehensive investigation was performed to analyze the potential of a novel method, fenton mediated sonic disintegration (FSD). In FSD process, extracellular polymeric substance (EPS) of sludge was first removed via fenton treatment. It was subsequently disintegrated via ultrasonication. Energetic assessment and economic analysis were then performed using net energy and cost gain (spent) as key factor to evaluate the practical viability of the FSD process. FSD was found to be superior over sonic disintegration based on its higher sludge solubilization (34.4% vs. 23.2%) and methane production potential (0.3gCOD/gCOD vs. 0.2gCOD/gCOD). Both energy analysis and cost assessment of the present study revealed that FSD could reduce the energy demand of ultrasonication considerably with a positive net profit of about 44.93USD/Ton of sludge. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Investigation of optimum conditions and costs estimation for degradation of phenol by solar photo-Fenton process

    Science.gov (United States)

    Gar Alalm, Mohamed; Tawfik, Ahmed; Ookawara, Shinichi

    2017-03-01

    In this study, solar photo-Fenton reaction using compound parabolic collectors reactor was assessed for removal of phenol from aqueous solution. The effect of irradiation time, initial concentration, initial pH, and dosage of Fenton reagent were investigated. H2O2 and aromatic intermediates (catechol, benzoquinone, and hydroquinone) were quantified during the reaction to study the pathways of the oxidation process. Complete degradation of phenol was achieved after 45 min of irradiation when the initial concentration was 100 mg/L. However, increasing the initial concentration up to 500 mg/L inhibited the degradation efficiency. The dosage of H2O2 and Fe+2 significantly affected the degradation efficiency of phenol. The observed optimum pH for the reaction was 3.1. Phenol degradation at different concentration was fitted to the pseudo-first order kinetic according to Langmuir-Hinshelwood model. Costs estimation for a large scale reactor based was performed. The total costs of the best economic condition with maximum degradation of phenol are 2.54 €/m3.

  10. Dewaterability of five sewage sludges in Guangzhou conditioned with Fenton's reagent/lime and pilot-scale experiments using ultrahigh pressure filtration system.

    Science.gov (United States)

    Liang, Jialin; Huang, Shaosong; Dai, Yongkang; Li, Lei; Sun, Shuiyu

    2015-11-01

    Sludge conditioning with Fenton's reagent and lime is a valid method for sludge dewatering. This study investigated the influence of different organic matter content sludge on sludge dewatering and discussed the main mechanism of sludge conditioning by combined Fenton's reagent and lime. The results indicated that the specific resistance to filterability (SRF) of sludge was reduced efficiently by approximately 90%, when conditioned with Fenton's reagent and lime. Through single factor experiments, the optimal conditioning combinations were found. In addition, the relationship between VSS% and consumption of the reagents was detected. Furthermore, it was also demonstrated that the SRF and filtrate TOC values had a significant correlation with VSS% of sludge (including raw and conditioned). The main mechanism of sludge dewatering was also investigated. Firstly, it revealed that the dewaterability of sludge was closely correlated to extracellular polymeric substances (EPS) and bound water contents. Secondly, the results of scanning electron microscopy (SEM) stated that sludge particles were to be smaller and thinner after conditioning. And this structure could easily form outflow channels for releasing free water. Additionally, with the ultrahigh pressure filtration system, the water content of sludge cake conditioned with Fenton's reagent and lime could be reduced to below 50%. Moreover, the economic assessment shows that Fenton's reagent and lime combined with ultrahigh pressure filtration system can be an economical and viable technology for sewage sludge dewatering. Finally, three types of sludge were classified: (1) Fast to dewater; (2) Moderately fast to dewater; (3) Slow to dewater sludge. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Integrating the Fenton's Process with Biofiltration by to Reduce Chemical Oxygen Demand of Winery Effluents.

    Science.gov (United States)

    Pipolo, Marco; Martins, Rui C; Quinta-Ferreira, Rosa M; Costa, Raquel

    2017-03-01

    The discharge of poorly decontaminated winery wastewater remains a serious environmental problem in many regions, and the industry is welcoming improved treatment methods. Here, an innovative decontamination approach integrating Fenton's process with biofiltration by Asian clams is proposed. The potential of this approach was assessed at the pilot scale using real effluent and by taking an actual industrial treatment system as a benchmark. Fenton peroxidation was observed to remove 84% of the effluent's chemical oxygen demand (COD), reducing it to 205 mg L. Subsequent biofiltration decreased the effluent's COD to approximately zero, well below the legal discharge limit of 150 mg L, in just 3 d. The reduction of the effluent's organic load through Fenton's process did not decrease its toxicity toward , but the effluent was much less harmful after biofiltration. The performance of the treatment proposed exceeded that of the integrated Fenton's process-sequencing batch reactor design implemented in the winery practice, where a residence time of around 10 d in the biological step typically results in 80 to 90% of COD removal. The method proposed is effective and compatible with typical winery budgets and potentially contributes to the management of a nuisance species. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  12. Degradation mechanism of Direct Pink 12B treated by iron-carbon micro-electrolysis and Fenton reaction.

    Science.gov (United States)

    Wang, Xiquan; Gong, Xiaokang; Zhang, Qiuxia; Du, Haijuan

    2013-12-01

    The Direct Pink 12B dye was treated by iron-carbon micro-electrolysis (ICME) and Fenton oxidation. The degradation pathway of Direct Pink 12B dye was inferred by ultraviolet visible (UV-Vis), infrared absorption spectrum (IR) and high performance liquid chromatography-mass spectrometry (HPLC-MS). The major reason of decolorization was that the conjugate structure was disrupted in the iron-carbon micro-electrolysis (ICME) process. However, the dye was not degraded completely because benzene rings and naphthalene rings were not broken. In the Fenton oxidation process, the azo bond groups surrounded by higher electron cloud density were first attacked by hydroxyl radicals to decolorize the dye molecule. Finally benzene rings and naphthalene rings were mineralized to H2O and CO2 under the oxidation of hydroxyl radicals. Copyright © 2013 The Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences. Published by Elsevier B.V. All rights reserved.

  13. A thermodynamic study of waste heat recovery from GT-MHR using organic Rankine cycles

    International Nuclear Information System (INIS)

    Yari, Mortaza; Mahmoudi, S.M.S.

    2011-01-01

    This paper presents an investigation on the utilization of waste heat from a gas turbine-modular helium reactor (GT-MHR) using different arrangements of organic Rankine cycles (ORCs) for power production. The considered organic Rankine cycles were: simple organic Rankine cycle (SORC), ORC with internal heat exchanger (HORC) and regenerative organic Rankine cycle (RORC). The performances of the combined cycles were studied from the point of view of first and second-laws of thermodynamics. Individual models were developed for each component and the effects of some important parameters such as compressor pressure ratio, turbine inlet temperature, and evaporator and environment temperatures on the efficiencies and on the exergy destruction rate were studied. Finally the combined cycles were optimized thermodynamically using the EES (Engineering Equation Solver) software. Based on the identical operating conditions for the GT-MHR cycle, a comparison between the three combined cycles and a simple GT-MHR cycle is also were made. This comparison was also carried out from the point of view of economics. The GT-MHR/SORC combined cycle proved to be the best among all the cycles from the point of view of both thermodynamics and economics. The efficiency of this cycle was about 10% higher than that of GT-MHR alone. (orig.)

  14. Nanoparticle-assisted photo-Fenton reaction for photo-decomposition of humic acid

    Science.gov (United States)

    Banik, Jhuma; Basumallick, Srijita

    2017-11-01

    We report here the synthesis of CuO-doped ZnO composite nanomaterials (NMs) by chemical route and demonstrated for the first time that these NMs are efficient catalysts for H2O2-assisted photo-decomposition (photo-Fenton type catalyst) of humic acid, a natural pollutant of surface water by solar irradiation. This has been explained by faster electron transfer to OH radical at the p-n hetero-junction of this composite catalyst. Application of this composite catalyst in decomposing humus substances of local pond water by solar energy has been demonstrated.

  15. Ground reaction force estimates from ActiGraph GT3X+ hip accelerations.

    Directory of Open Access Journals (Sweden)

    Jennifer M Neugebauer

    Full Text Available Simple methods to quantify ground reaction forces (GRFs outside a laboratory setting are needed to understand daily loading sustained by the body. Here, we present methods to estimate peak vertical GRF (pGRFvert and peak braking GRF (pGRFbrake in adults using raw hip activity monitor (AM acceleration data. The purpose of this study was to develop a statistically based model to estimate pGRFvert and pGRFbrake during walking and running from ActiGraph GT3X+ AM acceleration data. 19 males and 20 females (age 21.2 ± 1.3 years, height 1.73 ± 0.12 m, mass 67.6 ± 11.5 kg wore an ActiGraph GT3X+ AM over their right hip. Six walking and six running trials (0.95-2.19 and 2.20-4.10 m/s, respectively were completed. Average of the peak vertical and anterior/posterior AM acceleration (ACCvert and ACCbrake, respectively and pGRFvert and pGRFbrake during the stance phase of gait were determined. Thirty randomly selected subjects served as the training dataset to develop generalized equations to predict pGRFvert and pGRFbrake. Using a holdout approach, the remaining 9 subjects were used to test the accuracy of the models. Generalized equations to predict pGRFvert and pGRFbrake included ACCvert and ACCbrake, respectively, mass, type of locomotion (walk or run, and type of locomotion acceleration interaction. The average absolute percent differences between actual and predicted pGRFvert and pGRFbrake were 8.3% and 17.8%, respectively, when the models were applied to the test dataset. Repeated measures generalized regression equations were developed to predict pGRFvert and pGRFbrake from ActiGraph GT3X+ AM acceleration for young adults walking and running. These equations provide a means to estimate GRFs without a force plate.

  16. Inactivation of natural enteric bacteria in real municipal wastewater by solar photo-Fenton at neutral pH.

    Science.gov (United States)

    Ortega-Gómez, E; Esteban García, B; Ballesteros Martín, M M; Fernández Ibáñez, P; Sánchez Pérez, J A

    2014-10-15

    This study analyses the use of the solar photo-Fenton treatment in compound parabolic collector photo-reactors at neutral pH for the inactivation of wild enteric Escherichia coli and total coliform present in secondary effluents of a municipal wastewater treatment plant (SEWWTP). Control experiments were carried out to find out the individual effects of mechanical stress, pH, reactants concentration, and UVA radiation as well as the combined effects of UVA-Fe and UVA-H2O2. The synergistic germicidal effect of solar-UVA with 50 mg L(-1) of H2O2 led to complete disinfection (up to the detection limit) of total coliforms within 120 min. The disinfection process was accelerated by photo-Fenton, achieving total inactivation in 60 min reducing natural bicarbonate concentration found in the SEWWTP from 250 to 100 mg L(-1) did not give rise to a significant enhancement in bacterial inactivation. Additionally, the effect of hydrogen peroxide and iron dosage was evaluated. The best conditions were 50 mg L(-1) of H2O2 and 20 mg L(-1) of Fe(2+). Due to the variability of the SEWWTP during autumn and winter seasons, the inactivation kinetic constant varied between 0.07 ± 0.04 and 0.17 ± 0.04 min(-1). Moreover, the water treated by solar photo-Fenton fulfilled the microbiological quality requirement for wastewater reuse in irrigation as per the WHO guidelines and in particular for Spanish legislation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. International co-operation in developing the GT-MHR

    International Nuclear Information System (INIS)

    La Bar, M.P.; Simon, W.A.

    1997-01-01

    In the Fall of 1995, driven by budget constraints and anti-nuclear sentiments, the US government decided to discontinue financial support of the Gas Turbine-Modular Helium Reactor (GT-MHR). At that time, significant work was underway with participation of several vendors with specialized expertise in various aspects of the GT-MHR. Fortunately the US government provided for documenting the design and development status through an orderly close-out program. Concurrent elimination of government restrictions opened the door for broader international cooperation. Discussion between General Atomics and the Russian Ministry of Atomic Energy (MINATOM), in the summer of 1994, led to an agreement on a jointly funded design and development program for the GT-MHR. The program is initially focused on the burning of weapons plutonium that becomes available from dismantled nuclear weapons. The long term goal is to utilize the same design for commercial applications - using uranium fuel. This program took advantage of existing technologies and facilities in the US and Russia, but right from the beginning left the door open for broader international cooperation. Accordingly, in January 1996, FRAMATOME has joined the ongoing effort. Discussions are underway with other international entities to join this program. The program is proceeding well. Several Russian laboratories/design organizations are participating with GA and FRAMATOME. Significant improvements in the power conversion system design are a clear example of the benefit of the cooperative effort. Further work needs to be done to confirm fuel and components prior to full deployment, etc., providing ample opportunities for international cooperation in many areas

  18. Use of Pillared Clay-Based Catalysts for Wastewater Treatment through Fenton-Like Processes

    OpenAIRE

    J. Herney-Ramírez; Luis M. Madeira

    2010-01-01

    Clays, both natural and physical-chemically modified, are attractive materials for the preparation of supported catalysts. In this chapter, a review is made regarding the use of pillared interlayered clays (PILCs) in heterogeneous Fenton-like advanced oxidation processes. Their applications in pollutants degradation is summarized, with particular emphasis on the effect of the main operating conditions (e.g., initial H2O2 or parent compound concentration, catalyst load, pH, or temperature) on ...

  19. Detoxification and biodegradability enhancement of aqueous solutions of four commercial pesticides along a Photo-Fenton treatment

    International Nuclear Information System (INIS)

    Amat, A. M.; Arques, A.; Domenech, A.; Garcia-Ripoll, A.; Vicente, R.

    2009-01-01

    Photo-Fenton treatment has proven to be efficient to remove recalcitrant pollutants as commercial pesticides commonly employed in citric cultivars in the Mediterranean coast of Spain as Laition, Sevnol, Ultracid and Metasystox. However, the photon-Fenton treatment resulted to be less efficient to remove organic matter; nevertheless it could be employed as a pre-treatment to couple with biological processes, widely used in wastewater treatment. (Author)

  20. Detoxification and biodegradability enhancement of aqueous solutions of four commercial pesticides along a Photo-Fenton treatment

    Energy Technology Data Exchange (ETDEWEB)

    Amat, A. M.; Arques, A.; Domenech, A.; Garcia-Ripoll, A.; Vicente, R.

    2009-07-01

    Photo-Fenton treatment has proven to be efficient to remove recalcitrant pollutants as commercial pesticides commonly employed in citric cultivars in the Mediterranean coast of Spain as Laition, Sevnol, Ultracid and Metasystox. However, the photon-Fenton treatment resulted to be less efficient to remove organic matter; nevertheless it could be employed as a pre-treatment to couple with biological processes, widely used in wastewater treatment. (Author)

  1. Supported Nanosized α-FeOOH Improves Efficiency of Photoelectro-Fenton Process with Reaction-Controlled pH Adjustment for Sustainable Water Treatment

    Directory of Open Access Journals (Sweden)

    Chuan Wang

    2012-01-01

    Full Text Available The overall photoelectro-Fenton (PE-Fenton process for water treatment with neutral initial pH includes three steps of pH reduction, PE-Fenton reaction, and pH elevation. Reaction-controlled pH adjustment (RCpA, which utilizes the intrinsic electrochemical reactions instead of chemical addition, has been employed to lower the pH, maintain the lowered pH for the Fenton reaction, and recover the pH for final effluent discharge. This study demonstrated that the overall efficiency of this sustainable PE-Fenton process was improved by rapidly recycling the iron substance. Nanosized iron oxide was prepared and employed to ensure such rapid recycling. SEM and XRD results showed that the as-prepared iron oxide was α-FeOOH with 20 nm in size. The experimental results of dimethyl phthalate (DMP degradation showed that diatomite-supported α-FeOOH (N-α-FeOOH/diatomite could efficiently reduce the DMP concentration and total organic carbon. Furthermore, compared with Fe3+, the N-α-FeOOH/diatomite saved 160 min for iron settlement at 20 mg L−1 DMP concentration. Also, with the increment in the initial DMP concentration, extra energy consumed by the individual step of PE-Fenton reaction using the N-α-FeOOH/diatomite became negligible compared with that using free iron ions with the increment in the initial DMP concentration. This development is expected to be a major step of the PE-Fenton process with RCpA towards actual water treatment.

  2. Tratamento do lixiviado de aterro de resíduos sólidos urbanos por processo Fenton

    Directory of Open Access Journals (Sweden)

    Victor Wegner Maus

    2009-01-01

    Full Text Available O lixiviado gerado em aterros sanitários pela decomposição dos resíduos sólidos com presença de água de infiltração possuigrande potencial poluidor, devido à elevada concentração de substâncias tóxicas e a sua baixa biodegradabilidade. A coagulaçãoquímica pode ser uma alternativa para o tratamento de efluentes com essas características. O trabalho teve como objetivo avaliar aeficiência do processo Fenton no tratamento de lixiviado gerado em aterros sanitários de resíduos sólidos urbanos. As amostras delixiviado foram coletadas no aterro controlado do município de Santa Maria – RS. No experimento foram testados cincotratamentos com diferentes proporções de reagentes (H2O2 e FeSO4 TH2O2/FeSO4: T0,8, T2,0, T3,0, T4,0 e T6,0. Pelos resultados doexperimento com processo Fenton verifica-se uma eficiência média na remoção da demanda química de oxigênio (DQO de47,9%, na turbidez de 53,0% e na cor de 70,7%. Os valores médios da demanda bioquímica de oxigênio (DBO e dacondutividade elétrica aumentaram em 31,3% e 27,1%, respectivamente. No tratamento T0,8 constatou-se a maior remoção daDQO e o maior aumento da biodegradabilidade. O processo Fenton aplicado no tratamento de lixiviado reduz a DQO e aumenta aDBO, em outras palavras, aumenta a biodegradabilidade do efluente. Esse processo pode ser utilizado como pré-tratamento de umsistema biológico para efluentes de aterros sanitários.Abstract The leachate generated on sanitary landfill bysolid waste decomposition with rainfall water infiltration hashigh potential of pollution, due to high concentration oftoxic substances and low biodegradability. The chemistrycoagulation can be an alternative to treat effluents with thesecharacteristics. The work aimed to evaluate the efficiency ofFenton process in the treatment of leachate landfill fromurban solid waste. The leachate samples were collected fromthe controlled landfill of Santa Maria Council – RS. In theexperiment

  3. Fenton oxidation to remediate PAHs in contaminated soils: A critical review of major limitations and counter-strategies.

    Science.gov (United States)

    Usman, M; Hanna, K; Haderlein, S

    2016-11-01

    Fenton oxidation constitutes a viable remediation strategy to remove polycyclic aromatic hydrocarbons (PAHs) in contaminated soils. This review is intended to illustrate major limitations associated with this process like acidification, PAH unavailability, and deterioration of soil quality along with associated factors, followed by a critical description of various developments to overcome these constraints. Considering the limitation that its optimal pH is around 3, traditional Fenton treatment could be costly, impractical in soil due to the high buffering capacity of soils and associated hazardous effects. Use of various chelating agents (organic or inorganic) allowed oxidation at circumneutral pH but factors like higher oxidant demand, cost and toxicity should be considered. Another alternative is the use of iron minerals that can catalyze Fenton-like oxidation over a wide range of pH, but mobility of these particles in soils (i.e. saturated and unsaturated zones) should be investigated prior to in-situ applications. The PAH-unavailability is the crucial limitation hindering their effective degradation. Research data is compiled describing various strategies to address this issue like the use of availability enhancement agents, extraction or thermal pretreatment. Last section of this review is devoted to describe the effects of various developments in Fenton treatment onto soil quality and native microbiota. Finally, research gaps are discussed to suggest future directions in context of applying Fenton oxidation to remediate contaminated soils. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. GT-WGS: an efficient and economic tool for large-scale WGS analyses based on the AWS cloud service.

    Science.gov (United States)

    Wang, Yiqi; Li, Gen; Ma, Mark; He, Fazhong; Song, Zhuo; Zhang, Wei; Wu, Chengkun

    2018-01-19

    Whole-genome sequencing (WGS) plays an increasingly important role in clinical practice and public health. Due to the big data size, WGS data analysis is usually compute-intensive and IO-intensive. Currently it usually takes 30 to 40 h to finish a 50× WGS analysis task, which is far from the ideal speed required by the industry. Furthermore, the high-end infrastructure required by WGS computing is costly in terms of time and money. In this paper, we aim to improve the time efficiency of WGS analysis and minimize the cost by elastic cloud computing. We developed a distributed system, GT-WGS, for large-scale WGS analyses utilizing the Amazon Web Services (AWS). Our system won the first prize on the Wind and Cloud challenge held by Genomics and Cloud Technology Alliance conference (GCTA) committee. The system makes full use of the dynamic pricing mechanism of AWS. We evaluate the performance of GT-WGS with a 55× WGS dataset (400GB fastq) provided by the GCTA 2017 competition. In the best case, it only took 18.4 min to finish the analysis and the AWS cost of the whole process is only 16.5 US dollars. The accuracy of GT-WGS is 99.9% consistent with that of the Genome Analysis Toolkit (GATK) best practice. We also evaluated the performance of GT-WGS performance on a real-world dataset provided by the XiangYa hospital, which consists of 5× whole-genome dataset with 500 samples, and on average GT-WGS managed to finish one 5× WGS analysis task in 2.4 min at a cost of $3.6. WGS is already playing an important role in guiding therapeutic intervention. However, its application is limited by the time cost and computing cost. GT-WGS excelled as an efficient and affordable WGS analyses tool to address this problem. The demo video and supplementary materials of GT-WGS can be accessed at https://github.com/Genetalks/wgs_analysis_demo .

  5. Optimization of photo-Fenton process for the treatment of prednisolone.

    Science.gov (United States)

    Díez, Aida María; Ribeiro, Ana Sofia; Sanromán, Maria Angeles; Pazos, Marta

    2018-03-29

    Prednisolone is a widely prescribed synthetic glucocorticoid and stated to be toxic to a number of non-target aquatic organisms. Its extensive consumption generates environmental concern due to its detection in wastewater samples at concentrations ranged from ng/L to μg/L that requests the application of suitable degradation processes. Regarding the actual treatment options, advanced oxidation processes (AOPs) are presented as a viable alternative. In this work, the comparison in terms of pollutant removal and energetic efficiencies, between different AOPs such as Fenton (F), photo-Fenton (UV/F), photolysis (UV), and hydrogen peroxide/photolysis (UV/H 2 O 2 ), was carried out. Light diode emission (LED) was the selected source to provide the UV radiation. The UV/F process revealed the best performance, reaching high levels of both degradation and mineralization with low energy consumption. Its optimization was conducted and the operational parameters were iron and H 2 O 2 concentrations and the working volume. Using the response surface methodology with the Box-Behnken design, the effect of independent variables and their interactions on the process response were effectively evaluated. Different responses were analyzed taking into account the prednisolone removal (TOC and drug abatements) and the energy consumptions associated. The obtained model showed an improvement of the UV/F process when treating smaller volumes and when adding high concentrations of H 2 O 2 and Fe 2+ . The validation of this model was successfully carried out, having only 5% of discrepancy between the model and the experimental results. Finally, the performance of the process when having a real wastewater matrix was also tested, achieving complete mineralization and detoxification after 8 h. In addition, prednisolone degradation products were identified. Finally, the obtained low energy permitted to confirm the viability of the process.

  6. NATURAL IRON OXIDE AS A HETEROGENEOUS PHOTO-FENTON-LIKE CATALYST FOR THE DEGRADATION OF 1-NAPHTHOL UNDER ARTIFICIAL AND SOLAR LIGHT

    Directory of Open Access Journals (Sweden)

    L MAMMERI

    2014-07-01

    Full Text Available A heterogeneous photo-Fenton-like degradation process of 1-naphthol (1-NP promoted by natural iron oxide (NIO in the presence of H2O2 was studied under artificial (365 nm and solar irradiation. This is an important reaction for the environment since both H2O2 and iron oxides are common constituents of natural waters. Furthermore, iron oxides function as catalysts in chemical oxidation processes used with H2O2 for treatment of contaminated waters. The NIO used in this study was characterized by X-ray diffraction (XRD, X-ray fluorescence and Brunauer–Emmett–Teller (BET methods. The results show that the NIO is a composite material that contains predominantly crystalline hematite particales (Fe2O3. The Fe2O3 in NIO was able to initiate the Fenton-like and photo-Fenton-like reactions. The effects of initial pH, catalyst dosage, H2O2 concentration and the wavelength of the light source (UV and solar on the photodegradation of 1-NP were investigated. The optimal content of the NIO was 1 g L-1 and the optimal H2O2 concentration was 10 mM. The degradation could occur efficiently over a wide pH range of 3-8.3. Furthermore, an important effect of light was observed. The photo-oxidation of 1-NP in NIO-H2O2 system under solar light was significantly accelerated in comparison with artificial irradiation at 365 nm.

  7. Removal of organic pollutants from industrial wastewater by applying photo-Fenton oxidation technology

    OpenAIRE

    Ebrahiem E. Ebrahiem; Mohammednoor N. Al-Maghrabi; Ahmed R. Mobarki

    2017-01-01

    The general strategy of this study was based on evaluation of the possibility of applying advanced photo-oxidation technique (Fenton oxidation process) for removal of the residuals organic pollutants present in cosmetic wastewater. The different parameters that affect the chemical oxidation process for dyes in their aqueous solutions were studied by using Fenton’s reaction. These parameters are pH, hydrogen peroxide (H2O2) dose, ferrous sulfate (FeSO4·7H2O) dose, Initial dye concentration, an...

  8. Fenton-like reaction: a possible way to efficiently remove illicit drugs and pharmaceuticals from wastewater.

    Science.gov (United States)

    Mackuľak, Tomáš; Mosný, Michal; Grabic, Roman; Golovko, Oksana; Koba, Olga; Birošová, Lucia

    2015-03-01

    We analyzed 13 psychoactive pharmaceuticals, illicit drugs and their metabolites in wastewater treatment plant influent and effluent and the possibility of their degradation by biological and chemical processes. Tramadol (413-853 ng/L) and methamphetamine (460-682 ng/L) were the most concentrated compounds in the wastewater in winter and summer, respectively. A significant decrease in the concentration of tramadol in wastewater was measured during the summer. The lowest efficiency was observed for tramadol, venlafaxine, citalopram and oxazepam (∼ 10%) and the highest efficiency was observed for amphetamine and THC-COOH (∼ 80%). The efficiency of compound degradation via the Fenton reaction, a modified Fenton reaction and different degradation (by algae, wood-rotting fungi and enzymes at influent versus effluent) was determined. The Fenton reaction and its modification were efficient at eliminating these substances in comparison with the tested biological processes. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Preparation of nickel ferrite/carbon nanotubes composite by microwave irradiation technique for use as catalyst in photo-fenton reaction

    Energy Technology Data Exchange (ETDEWEB)

    Foletto, E.L.; Rigo, C.; Severo, E.C.; Mazutti, M.A.; Dotto, G.L.; Jahn, S.L.; Sales, J.C. [Universidade Federal de Santa Maria (UFSM), RS (Brazil); Chiavone-Filho, O. [Universidade Federal do Rio Grande do Sul (UFRGS), RS (Brazil); Gundel, A.; Lucchese, M. [Universidade Federal do Pampa (UNIPAMPA), Bage, RS (Brazil)

    2016-07-01

    Full text: Nickel ferrite/multi-walled carbon nanotubes (NiFe2O4/MWCNTs) composite has been rapidly synthesized via microwave irradiation technique. The structural properties of the formed product was investigated by X-ray diffraction (XRD), N2 adsorption/desorption isotherms, thermogravimetric analysis (TGA), Raman spectroscopy and, scanning electron microscopy (SEM). The catalytic behavior of composite material was evaluated by the degradation of Amaranth dye in the photo-Fenton reaction under visible light irradiation. The overall results showed that the prepared composite was successfully synthesized, demonstrating good performance in the dye degradation, with higher degradation rate compared to the NiFe2O4. The high efficiency in dye degradation can be attributed to synergism between NiFe2O4 and MWCNTs. Therefore, NiFe2O4/MWCNTs composite can be used as promising photo-Fenton catalyst to degrade Amaranth dye from aqueous solutions. (author)

  10. Improvement of COD and color removal from UASB treated poultry manure wastewater using Fenton's oxidation

    International Nuclear Information System (INIS)

    Yetilmezsoy, Kaan; Sakar, Suleyman

    2008-01-01

    The applicability of Fenton's oxidation as an advanced treatment for chemical oxygen demand (COD) and color removal from anaerobically treated poultry manure wastewater was investigated. The raw poultry manure wastewater, having a pH of 7.30 (±0.2) and a total COD of 12,100 (±910) mg/L was first treated in a 15.7 L of pilot-scale up-flow anaerobic sludge blanket (UASB) reactor. The UASB reactor was operated for 72 days at mesophilic conditions (32 ± 2 deg. C) in a temperature-controlled environment with three different hydraulic retention times (HRT) of 15.7, 12 and 8.0 days, and with organic loading rates (OLR) between 0.650 and 1.783 kg COD/(m 3 day). Under 8.0 days of HRT, the UASB process showed a remarkable performance on total COD removal with a treatment efficiency of 90.7% at the day of 63. The anaerobically treated poultry manure wastewater was further treated by Fenton's oxidation process using Fe 2+ and H 2 O 2 solutions. Batch tests were conducted on the UASB effluent samples to determine the optimum operating conditions including initial pH, effects of H 2 O 2 and Fe 2+ dosages, and the ratio of H 2 O 2 /Fe 2+ . Preliminary tests conducted with the dosages of 100 mg Fe 2+ /L and 200 mg H 2 O 2 /L showed that optimal initial pH was 3.0 for both COD and color removal from the UASB effluent. On the basis of preliminary test results, effects of increasing dosages of Fe 2+ and H 2 O 2 were investigated. Under the condition of 400 mg Fe 2+ /L and 200 mg H 2 O 2 /L, removal efficiencies of residual COD and color were 88.7% and 80.9%, respectively. Under the subsequent condition of 100 mg Fe 2+ /L and 1200 mg H 2 O 2 /L, 95% of residual COD and 95.7% of residual color were removed from the UASB effluent. Results of this experimental study obviously indicated that nearly 99.3% of COD of raw poultry manure wastewater could be effectively removed by a UASB process followed by Fenton's oxidation technology used as a post-treatment unit

  11. Improvement of COD and color removal from UASB treated poultry manure wastewater using Fenton's oxidation.

    Science.gov (United States)

    Yetilmezsoy, Kaan; Sakar, Suleyman

    2008-03-01

    The applicability of Fenton's oxidation as an advanced treatment for chemical oxygen demand (COD) and color removal from anaerobically treated poultry manure wastewater was investigated. The raw poultry manure wastewater, having a pH of 7.30 (+/-0.2) and a total COD of 12,100 (+/-910) mg/L was first treated in a 15.7 L of pilot-scale up-flow anaerobic sludge blanket (UASB) reactor. The UASB reactor was operated for 72 days at mesophilic conditions (32+/-2 degrees C) in a temperature-controlled environment with three different hydraulic retention times (HRT) of 15.7, 12 and 8.0 days, and with organic loading rates (OLR) between 0.650 and 1.783 kg COD/(m3day). Under 8.0 days of HRT, the UASB process showed a remarkable performance on total COD removal with a treatment efficiency of 90.7% at the day of 63. The anaerobically treated poultry manure wastewater was further treated by Fenton's oxidation process using Fe2+ and H2O2 solutions. Batch tests were conducted on the UASB effluent samples to determine the optimum operating conditions including initial pH, effects of H2O2 and Fe2+ dosages, and the ratio of H2O2/Fe2+. Preliminary tests conducted with the dosages of 100 mg Fe2+/L and 200 mg H2O2/L showed that optimal initial pH was 3.0 for both COD and color removal from the UASB effluent. On the basis of preliminary test results, effects of increasing dosages of Fe2+ and H2O2 were investigated. Under the condition of 400 mg Fe2+/L and 200 mg H2O2/L, removal efficiencies of residual COD and color were 88.7% and 80.9%, respectively. Under the subsequent condition of 100 mg Fe2+/L and 1200 mg H2O2/L, 95% of residual COD and 95.7% of residual color were removed from the UASB effluent. Results of this experimental study obviously indicated that nearly 99.3% of COD of raw poultry manure wastewater could be effectively removed by a UASB process followed by Fenton's oxidation technology used as a post-treatment unit.

  12. Sequential pretreatment for cell disintegration of municipal sludge in a neutral Bio-electro-Fenton system.

    Science.gov (United States)

    Yu, Qilin; Jin, Xiaochen; Zhang, Yaobin

    2018-05-15

    Sludge cell disruption was generally considered as the rate-limiting step for the anaerobic digestion of waste activated sludge (WAS). Advanced oxidation processes and bio-electro-chemical systems were recently reported to enhance the hydrolysis of WAS and sludge cell disruption, while the cell-breaking processes of these systems remain unclear yet. In this study, an innovative Bio-electro-Fenton system was developed to pretreat the WAS sequentially with cathode Fenton process and anode anaerobic digestion. Significant cell disruption and dissolution intracellular organics were founded after the treatment. X-ray photoelectron spectroscopy (XPS) analysis and fourier transform infrared spectroscopy (FT-IR) spectra indicated that Gram-negative bacteria were more sensitive to free radicals yielded in cathode to induce a chain reaction that destroyed the lipid-contained outer membrane, while Gram-positive bacteria with thick peptidoglycan layer were liable to be biologically decomposed in the anode. Compared with the oxidation of organic matters in the cathode Fenton, the secretion of enzyme increased in the anode which was beneficial to break down the complex matters (peptidoglycans) into simples that were available for anode oxidation by exoelectrogens. The results also showed a possible prospect for the application of this sequential pretreatment in bio-electro-Fenton systems to disrupt sludge cells and enhance the anaerobic digestion. Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. Coupling solar photo-Fenton and biotreatment at industrial scale: Main results of a demonstration plant

    International Nuclear Information System (INIS)

    Malato, Sixto; Blanco, Julian; Maldonado, Manuel I.; Oller, Isabel; Gernjak, Wolfgang; Perez-Estrada, Leonidas

    2007-01-01

    This paper reports on the combined solar photo-Fenton/biological treatment of an industrial effluent (initial total organic carbon, TOC, around 500 mg L -1 ) containing a non-biodegradable organic substance (α-methylphenylglycine at 500 mg L -1 ), focusing on pilot plant tests performed for design of an industrial plant, the design itself and the plant layout. Pilot plant tests have demonstrated that biodegradability enhancement is closely related to disappearance of the parent compound, for which a certain illumination time and hydrogen peroxide consumption are required, working at pH 2.8 and adding Fe 2+ = 20 mg L -1 . Based on pilot plant results, an industrial plant with 100 m 2 of CPC collectors for a 250 L/h treatment capacity has been designed. The solar system discharges the wastewater (WW) pre-treated by photo-Fenton into a biotreatment based on an immobilized biomass reactor. First, results of the industrial plant are also presented, demonstrating that it is able to treat up to 500 L h -1 at an average solar ultraviolet radiation of 22.9 W m -2 , under the same conditions (pH, hydrogen peroxide consumption) tested in the pilot plant

  14. Treatment of hazardous landfill leachate using Fenton process followed by a combined (UASB/DHS) system.

    Science.gov (United States)

    Ismail, Sherif; Tawfik, Ahmed

    2016-01-01

    Fenton process for pre-treatment of hazardous landfill leachate (HLL) was investigated. Total, particulate and soluble chemical oxygen demand (CODt, CODp and CODs) removal efficiency amounted to 67%, 47% and 64%, respectively, at pH value of 3.5, molar ratio (H2O2/Fe(2+)) of 5, H2O2 dosage of 25 ml/L and contact time of 15 min. Various treatment scenarios were attempted and focused on studying the effect of pre-catalytic oxidation process on the performance of up-flow anaerobic sludge blanket (UASB), UASB/down-flow hanging sponge (DHS) and DHS system. The results obtained indicated that pre-catalytic oxidation process improved the CODt removal efficiency in the UASB reactor by a value of 51.4%. Overall removal efficiencies of CODt, CODs and CODp were 80 ± 6%, 80 ± 7% and 78 ± 16% for UASB/DHS treating pre-catalytic oxidation effluent, respectively. The removal efficiencies of CODt, CODs and CODp were, respectively, decreased to 54 ± 2%, 49 ± 2% and 71 ± 16% for UASB/DHS system without pre-treatment. However, the results for the combined process (UASB/DHS) system is almost similar to those obtained for UASB reactor treating pre-catalytic oxidation effluent. The DHS system achieved average removal efficiencies of 52 ± 4% for CODt, 51 ± 4% for CODs and 52 ± 15% for CODp. A higher COD fractions removal was obtained when HLL was pre-treated by Fenton reagent. The combined processes provided a removal efficiency of 85 ± 1% for CODt, 85 ± 1% for CODs and 83 ± 8% for CODp. The DHS system is not only effective for organics degradation but also for ammonia oxidation. Almost complete ammonia (NH4-N) removal (92 ± 3.6%) was occurred and the nitrate production amounted to 37 ± 6 mg/L in the treated effluent. This study strongly recommends applying Fenton process followed by DHS system for treatment of HLL.

  15. HydroHillChart – Francis module. Software used to Calculate the Hill Chart of the Francis Hydraulic Turbines

    Directory of Open Access Journals (Sweden)

    Dorian Nedelcu

    2015-07-01

    Full Text Available The paper presents the Hydro Hill Chart - Francis module application, used to calculate the hill chart of the Pelton, Francis and Kaplan hydraulic turbine models, by processing the data measured on the stand. After describing the interface and menu, the input data is graphically presented and the universal characteristic for measuring scenarios ao=const. and n11=const is calculated. Finally, the two calculated hill charts are compared through a graphical superimposition of the isolines.

  16. 27 CFR 9.190 - Red Hill Douglas County, Oregon.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Red Hill Douglas County... Areas § 9.190 Red Hill Douglas County, Oregon. (a) Name. The name of the viticultural area described in this section is “Red Hill Douglas County, Oregon”. For purposes of part 4 of this chapter, “Red Hill...

  17. For the Fenton process in a sequential downflow and upflow system to treat textile dyeing wastewater

    Energy Technology Data Exchange (ETDEWEB)

    Bae, W.K.; Ko, G.B.; Cho, S.J. [Dept. of Civil and Environmental Engineering, Hanyang Univ., Kyounggi (Korea); Lee, S.H. [Dept. of Environmental Engineering, Sangmyung Univ., Cheonan (Korea)

    2003-07-01

    Wastewater from textile dyeing industry is characterized by high temperature, pH, pollution loading such as color and COD which are containing refractory, toxic and high molecular weight compounds. It is therefore, presumed to be very resistant to microbial degradation. Textile dyeing wastewater is therefore, presumed to be very resistant to microbial degradation. Combined processes are usually applied, which are chemical oxidation and biological process for textile dyeing wastewater in order to satisfy water quality standards. Fenton process as advanced oxidation process is well known as effective process for the removal of color and recalcitrant organics. However, the exactly predominant reaction mechanisms during Fenton process are not well explained among coagulation, oxidation and sedimentation so far. This research attempts to evaluate the predominant reaction with comparable results of ferric coagulation and oxidation for the Fenton process. (orig.)

  18. Leachate treatment system using constructed wetlands, Town of Fenton sanitary landfill, Broome County, New York. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1993-11-01

    Municipal sanitary landfills generate leachate that New York State regulations require to be collected and treated to avoid contaminating surface water and groundwater. One option for treating leachate is to haul it to municipal wastewater treatment facility. This option may be expensive, may require excessive energy for transportation, and may require pretreatment to protect the receiving facility`s processes. An alternative is on-site treatment and discharge. Personnel from the Town of Fenton, New York; Hawk Engineering, P.C.; Cornell University; and Ithaca College designed, built, and operated a pilot constructed wetland for treating leachate at the Town of Fenton`s municipal landfill. The system, consisting of two overland flow beds and two subsurface flow beds has been effective for 18 months in reducing levels of ammonia (averaging 85% removal by volatilization and denitrification) and total iron (averaging 95% removal by precipitation and sedimentation), two key constituents of the Fenton landfill`s leachate. The system effects these reductions with zero chemical and energy inputs and minimal maintenance. A third key constituent of the leachate, manganese, apparently passes through the beds with minimal removal. Details and wetland considerations are described.

  19. Magnetic Fe2MO4 (M:Fe, Mn) activated carbons: Fabrication, characterization and heterogeneous Fenton oxidation of methyl orange

    International Nuclear Information System (INIS)

    Nguyen, Thi Dung; Phan, Ngoc Hoa; Do, Manh Huy; Ngo, Kim Tham

    2011-01-01

    We present a simple and efficient method for the fabrication of magnetic Fe 2 MO 4 (M:Fe and Mn) activated carbons (Fe 2 MO 4 /AC-H, M:Fe and Mn) by impregnating the activated carbon with simultaneous magnetic precursor and carbon modifying agent followed by calcination. The obtained samples were characterized by nitrogen adsorption isotherms, X-ray diffraction (XRD), scanning electron microscopy (SEM) and vibrating sample magnetometer (VSM), and the catalytic activity in heterogeneous Fenton oxidation of methyl orange (MO) was evaluated. The resulting Fe 2 MnO 4 /AC-H showed higher catalytic activity in the methyl orange oxidation than Fe 3 O 4 /AC-H. The effect of operational parameters (pH, catalyst loading H 2 O 2 dosage and initial MO concentration) on degradation performance of the oxidation process was investigated. Stability and reusability of selected catalyst were also tested.

  20. Current advances and trends in electro-Fenton process using heterogeneous catalysts - A review.

    Science.gov (United States)

    Poza-Nogueiras, Verónica; Rosales, Emilio; Pazos, Marta; Sanromán, M Ángeles

    2018-06-01

    Over the last decades, advanced oxidation processes have often been used alone, or combined with other techniques, for remediation of ground and surface water pollutants. The application of heterogeneous catalysis to electrochemical advanced oxidation processes is especially useful due to its efficiency and environmental safety. Among those processes, electro-Fenton stands out as the one in which heterogeneous catalysis has been broadly applied. Thus, this review has introduced an up-to-date collation of the current knowledge of the heterogeneous electro-Fenton process, highlighting recent advances in the use of different catalysts such as iron minerals (pyrite, magnetite or goethite), prepared catalysts by the load of metals in inorganic and organic materials, nanoparticles, and the inclusion of catalysts on the cathode. The effects of physical-chemical parameters as well as the mechanisms involved are critically assessed. Finally, although the utilization of this process to remediation of wastewater overwhelmingly outnumber other utilities, several applications have been described in the context of regeneration of adsorbent or the remediation of soils as clear examples of the feasibility of the electro-Fenton process to solve different environmental problems. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Terbium(III) ions as sensitizers of oxidation of indole and its derivatives in Fenton system

    Energy Technology Data Exchange (ETDEWEB)

    Kaczmarek, Małgorzata, E-mail: mkaczmar@amu.edu.pl; Staninski, Krzysztof

    2017-03-15

    Oxidation of indole and its derivatives in the Fenton system as a source of oxidising agents, in the presence of terbium(III) ions was studied by chemiluminescence methods to get the kinetic curves of emission decay and spectral distributions of chemiluminescence. Terbium(III) ions acted as a sensitizer of the mixtures Tb(III)-Fe(II)/Fe(III)-H{sub 2}O{sub 2}-indole or its derivative (tryptophan, tryptamine, indole-3-acetic acid and indole-3-acetyl aspartic acid). For the above indolic compounds, linear dependencies of integrated intensity of chemiluminescence on concentration of indolic compound in water and in water-acetonitrile solution were obtained. The limits of detection (LOD) and quantification (LOQ) of the indolic compounds studied were found to be by one or two orders of magnitude lower in the system with terbium(III) ions than without them. - Highlights: • Chemiluminescence emitted on oxidation of indolic compounds in Fenton system. • Tb (III) ions as sensitizers of indolic compounds oxidation in solutions. • Linear relations between CL intensity and indolic compound concentration.

  2. Direct conversion from Jerusalem artichoke to hydroxymethylfurfural (HMF) using the Fenton reaction.

    Science.gov (United States)

    Seo, Yeong Hwan; Han, Jong-In

    2014-05-15

    A simple method for hydroxymethylfurfural (HMF) production from non-crop biomass of the Jerusalem artichoke was developed using the Fenton reaction, in a mixture of 2-butanol and water. Four parameters (temperature, reaction time, Fe(2+) concentration, and H2O2 concentration) were identified as experimental factors, and HMF yield was selected as the response parameter. The experimental factors were optimised by employing Response Surface Methodology (RSM). The maximum HMF yield, of 46%, was obtained with a reaction time of 90 min, Fe(2+) concentration of 1.3 mM, and 0.47 M of H2O2 at 180 °C. Copyright © 2014. Published by Elsevier Ltd.

  3. Case study of the application of Fenton process to highly polluted wastewater from power plant.

    Science.gov (United States)

    Pliego, Gema; Zazo, Juan A; Casas, Jose A; Rodriguez, Juan J

    2013-05-15

    This work investigates the application of Fenton process to the treatment of a highly polluted industrial wastewater resulting from the pipeline cleaning in a power plant. This effluent is characterized by a high chemical oxygen demand (COD>40 g/L), low biodegradability and quite a high iron concentration (around 3g/L) this coming from pipeline corrosion. The effect of the initial reaction temperature (between 50 and 90 °C) and the way of feeding H2O2 on the mineralization percentage and the efficiency of H2O2 consumption has been analyzed. With the stoichiometric amount of H2O2 relative to initial COD, fed in continuous mode, more than 90% COD reduction was achieved at 90 °C. That was accompanied by a dramatic improvement of the biodegradability. Thus, a combined treatment based on semicontinuous high-temperature Fenton oxidation (SHTF) and conventional aerobic biological treatment would allow fulfilling the COD and ecotoxicity regional limits for industrial wastewaters into de municipal sewer system. For the sake of comparison, catalytic wet air oxidation was also tested with poor results (less than 30% COD removal at 140 °C and 8 atm oxygen pressure). Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Environmental sustainability of the solar photo-Fenton process for wastewater treatment and pharmaceuticals mineralization at semi-industrial scale.

    Science.gov (United States)

    Foteinis, Spyros; Monteagudo, Jose Maria; Durán, Antonio; Chatzisymeon, Efthalia

    2018-01-15

    The environmental sustainability of a semi-industrial solar photo-Fenton reactor, treating real effluents emanating from a pharmaceutical laboratory, is assessed herein. The life cycle assessment/analysis (LCA) methodology was employed and real life cycle inventory (LCI) data was collected from a ferrioxalate-assisted homogeneous solar photo-Fenton wastewater treatment plant (WWTP), at Ciudad Real, Spain. Electricity was provided by photovoltaic (PV) panels in tandem with a battery bank, making the plant autonomous from the local grid. The effective treatment of 1m 3 of secondary-treated pharmaceutical wastewater, containing antipyrine, was used as a functional unit. The main environmental hotspot was identified to be the chemical reagents used to enhance treatment efficiency, mainly hydrogen peroxide (H 2 O 2 ) and to a smaller degree oxalic acid. On the other hand, land use, PV panels, battery units, compound parabolic collectors (CPC), tanks, pipes and pumps, as materials, had a low contribution, ranging from as little as 0.06% up to about 2% on the total CO 2eq emissions. Overall, the solar photo-Fenton process was found to be a sustainable technology for treating wastewater containing micropollutants at semi-industrial level, since the total environmental footprint was found to be 2.71kgCO 2 m -3 or 272mPtm -3 , using IPCC 2013 and ReCiPe impact assessment methods, respectively. A sensitivity analysis revealed that if the excess of solar power is fed back into the grid then the total environmental footprint is reduced. Depending on the amount of solar power fed back into the grid the process could have a near zero total environmental footprint. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Remediação de solos contaminados por processos fenton: uma revisão crítica

    Directory of Open Access Journals (Sweden)

    Alecsandra dos Santos

    Full Text Available The remediation of contaminated soils is probably one of the biggest environmental challenges, mainly due to the complex dynamics of the pollutants in this medium. Among a variety of treatment alternatives proposed for the in-situ remediation of contaminated soils, Fenton processes appear as the most cost-effective, particularly when catalyzed by native iron oxides. However, both the efficiency of the Fenton process and its effect on the treated soil, are largely dependent of the treatment conditions and the main characteristics of the soil, which implies the nonexistence of universal procedures. In this work, the use of Fenton processes in soil remediation routines is critically evaluated, emphasizing aspects related to the degradation efficiency, the influence of the soil properties, the degradation mechanisms and the impacts on the treated soil.

  6. Comparison in decoloration efficiency among radiation, ultraviolet ray and Fenton oxidation treatment for aqueous solution of dyes

    International Nuclear Information System (INIS)

    Shimokawa, Toshishige; Sawai, Takeshi

    1984-01-01

    To establish the methods of oxidation and decomposition treatment for dyeing waste water, the processes by radiation, ultraviolet ray and Fenton oxidation were examined comparatively for the decoloration efficiency. The dyes tested were commercially available reactive dyes, RBO-3R, DBR-BB, MBY-6GS and RBB-R. In the radiation process, the dye solution was irradiated with gamma ray of cobalt-60 while blowing air through it. Radiation process and Fenton oxidation were excellent for decoloration. Ultraviolet ray was low in the treatment efficiency, so it is not practical. In the radiation process, the addition of a reagent and the adjustment of pH are not required unlike the case of the Fenton oxidation process. Its continuous operation is also possible, so it is a highly practical means. (Mori, K.)

  7. Response surface modeling for optimization heterocatalytic Fenton oxidation of persistence organic pollution in high total dissolved solid containing wastewater.

    Science.gov (United States)

    Sekaran, G; Karthikeyan, S; Boopathy, R; Maharaja, P; Gupta, V K; Anandan, C

    2014-01-01

    The rice-husk-based mesoporous activated carbon (MAC) used in this study was precarbonized and activated using phosphoric acid. N2 adsorption/desorption isotherm, X-ray powder diffraction, electron spin resonance, X-ray photoelectron spectroscopy and scanning electron microscopy, transmission electron microscopy, (29)Si-NMR spectroscopy, and diffuse reflectance spectroscopy were used to characterize the MAC. The tannery wastewater carrying high total dissolved solids (TDS) discharged from leather industry lacks biodegradability despite the presence of dissolved protein. This paper demonstrates the application of free electron-rich MAC as heterogeneous catalyst along with Fenton reagent for the oxidation of persistence organic compounds in high TDS wastewater. The heterogeneous Fenton oxidation of the pretreated wastewater at optimum pH (3.5), H2O2 (4 mmol/L), FeSO4[Symbol: see text]7H2O (0.2 mmol/L), and time (4 h) removed chemical oxygen demand, biochemical oxygen demand, total organic carbon and dissolved protein by 86, 91, 83, and 90%, respectively.

  8. Potential of Wood-Rotting Fungi to Attack Polystyrene Sulfonate and Its Depolymerisation by Gloeophyllum trabeum via Hydroquinone-Driven Fenton Chemistry.

    Directory of Open Access Journals (Sweden)

    Martin C Krueger

    Full Text Available Synthetic polymers often pose environmental hazards due to low biodegradation rates and resulting accumulation. In this study, a selection of wood-rotting fungi representing different lignocellulose decay types was screened for oxidative biodegradation of the polymer polystyrene sulfonate (PSS. Brown-rot basidiomycetes showed PSS depolymerisation of up to 50 % reduction in number-average molecular mass (Mn within 20 days. In-depth investigations with the most efficient depolymeriser, a Gloeophyllum trabeum strain, pointed at extracellular hydroquinone-driven Fenton chemistry responsible for depolymerisation. Detection of hydroxyl radicals present in the culture supernatants showed good compliance with depolymerisation over the time course of PSS degradation. 2,5-Dimethoxy-1,4-hydroquinone (2,5-DMHQ, which was detected in supernatants of active cultures via liquid chromatography and mass spectrometry, was demonstrated to drive the Fenton processes in G. trabeum cultures. Up to 80% reduction in Mn of PSS where observed when fungal cultures were additionally supplemented with 2,5-dimethoxy benzoquinone, the oxidized from of 2,5-DMHQ. Furthermore, 2,5-DMHQ could initiate the Fenton's reagent-mediated PSS depolymerisation in cell-free systems. In contrast, white-rot fungi were unable to cause substantial depolymerising effects despite the expression of lignin-modifying exo-enzymes. Detailed investigations with laccase from Trametes versicolor revealed that only in presence of certain redox mediators limited PSS depolymerisation occurred. Our results indicate that brown-rot fungi might be suitable organisms for the biodegradation of recalcitrant synthetic polymeric pollutants.

  9. Bio-Electro-Fenton process for the degradation of Non-Steroidal Anti-Inflammatory Drugs in wastewater

    DEFF Research Database (Denmark)

    Nadais, Helena; Li, Xiaohu; Alves, Nadine

    2018-01-01

    Non-Steroidal Anti-Inflammatory Drugs (NSAIDs) are ubiquitous municipal wastewater pollutants of which several are resistant to degradation in conventional wastewater treatment, and represent a major environmental health concern worldwide. An alternative treatment, the bio-electro-Fenton process......, has received increasing attention in past years. In this process the strong oxidant •HO is formed using the electrons derived from bacterial oxidation of organic substrate. In this work, a laboratory scale microbial electrolysis cell based bio-electro-Fenton process was developed for the treatment...

  10. IN-SITU REGENERATION OF GRANULAR ACTIVATED CARBON (GAC) USING FENTON'S REAGENTS

    Science.gov (United States)

    Fenton-dependent regeneration of granular activated carbon (GAC) initially saturated with one of several chlorinated aliphatic contaminants was studied in batch and continuous-flow reactors. Homogeneous and heterogeneous experiments were designed to investigate the effects of va...

  11. Fenton- and Persulfate-driven Regeneration of Contaminant-spent Granular Activated Carbon

    Science.gov (United States)

    Fenton- or persulfate-driven chemical oxidation regeneration of spent granular activated carbon (GAC) involves the combined, synergistic use of two treatment technologies: adsorption of organic chemicals onto GAC and chemical oxidation regeneration of the spent-GAC. Environmental...

  12. Using iron-loaded sepiolite obtained by adsorption as a catalyst in the electro-Fenton oxidation of Reactive Black 5.

    Science.gov (United States)

    Iglesias, O; Fernández de Dios, M A; Pazos, M; Sanromán, M A

    2013-09-01

    This study explores the possibility of using iron-loaded sepiolite, obtained by recovering iron from polluted water, as a catalyst in the electro-Fenton oxidation of organic pollutants in textile effluents. The removal of iron ions from aqueous solution by adsorption on sepiolite was studied in batch tests at iron concentrations between 100 and 1,000 ppm. Electro-Fenton experiments were carried out in an electrochemical cell with a working volume of 0.15 L, an air flow of 1 L/min, and 3 g of iron-loaded sepiolite. An electric field was applied using a boron-doped diamond anode and a graphite sheet cathode connected to a direct current power supply with a constant potential drop. Reactive Black 5 (100 mg/L) was selected as the model dye. The adsorption isotherms proved the ability of the used adsorbent. The removal of the iron ion by adsorption on sepiolite was in the range of 80-100 % for the studied concentration range. The Langmuir and Freundlich isotherms were found to be applicable in terms of the relatively high regression values. Iron-loaded sepiolite could be used as an effective heterogeneous catalyst for the degradation of organic dyes in the electro-Fenton process. Successive batch processes were performed at optimal working conditions (5 V and pH 2). The results indicate the suitability of the proposed combined process, adsorption to iron remediation followed by the application of the obtained iron-loaded sepiolite to the electro-Fenton technique, to oxidize polluted effluents.

  13. Efficient mineralization of the antibiotic trimethoprim by solar assisted photoelectro-Fenton process driven by a photovoltaic cell.

    Science.gov (United States)

    Zhang, Yanyu; Wang, Aimin; Tian, Xiujun; Wen, Zhenjun; Lv, Hanjiao; Li, Desheng; Li, Jiuyi

    2016-11-15

    In this study, a novel self-sustainable solar assisted photoelectro-Fenton (SPEF) system driven by a solar photovoltaic cell was developed for the efficient mineralization of antibiotic trimethoprim (TMP) in water. A comparative degradation of 200mgL(-1) TMP by RuO2/Ti anodic oxidation (AO), anodic oxidation with H2O2 electrogeneration (AO-H2O2), electro-Fenton (EF) and SPEF was investigated. SPEF was proved to exhibit the highest oxidation power, i.e., more than 80% TOC was removed after 360min SPEF treatment of 200mgL(-1) of TMP under optimal conditions at pH 3.0, 1.0mM Fe(2+) and 18mAcm(-2). Influences of current density, pH, initial Fe(2+) and initial TMP concentration on SPEF process were also studied. Ten aromatic intermediates generated from hydroxylation, carbonylation and demethylation reactions were identified using UPLC-QTOF-MS/MS system during the SPEF treatment, together with three carboxylic acids (oxamic, oxalic and formic acids) and two inorganic ions (NH4(+) and NO3(-)) measured. Therefore, a reasonable pathway of TMP degradation in SPEF process was proposed. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Photocatalytic degradation of Maxilon C.I. basic dye using CS/CoFe_2O_4/GONCs as a heterogeneous photo-Fenton catalyst prepared by gamma irradiation

    International Nuclear Information System (INIS)

    Al-Kahtani, Abdullah A.; Abou Taleb, Manal F.

    2016-01-01

    Highlights: • CS/CF/GONCs were synthesized via γ-irradiation and used as a heterogeneous photo-Fenton catalyst. • It can degrade Maxilon C.I. basic dye under sunlight irradiation. • A possible degradation pathway of Maxilon C.I. Basic was proposed. • The degradation of Maxilon follows pseudo-first-order kinetics. • The catalyst can be separated by an external magnetic field. • Cyclic degradation tests show the catalyst is highly active, stable and recoverable. - Abstract: CS/CF/GONCs were synthesized via gamma irradiation cross-linking method with the aid of sonication. The nanocomposites exhibited a photo-Fenton catalytic feature for the degradation of Maxilon C.I. basic dye in aqueous medium using sunlight. The effects of pH, H_2O_2 concentration, and dosage of the catalyst, on the degradation rates of the dyes were examined. The optimal degradation rate was reached with 10 mM H_2O_2 at pH 9.5. It was verified that the Maxilon C.I. basic dye degradation rate fits a pseudo-first-order kinetics for different initial concentrations of Maxilon C.I. dye. Fourth cyclic tests for Maxilon C.I. degradation showed that the magnetic catalyst was very stable, recoverable, highly active, and easy to separate using an external magnet. Hence, this magnetic catalyst has potential use in organic pollutant removal.

  15. Treatment of Furfural Wastewater by (AOPs Photo-Fenton Method

    Directory of Open Access Journals (Sweden)

    Yasmen A. Mustafa

    2015-03-01

    Full Text Available The objective of this study is to investigate the application of advanced oxidation processes (AOPs in the treatment of wastewater contaminated with furfural. The AOPs investigated is the homogeneous photo-Fenton (UV/H2O2/Fe+2 process. The experiments were conducted by using cylindrical stainless steel batch photo-reactor. The influence of different variables: initial concentration of H2O2 (300-1300mg/L, Fe+2(20-70mg/L, pH(2-7 and initial concentration of furfural (50-300 mg/L and their relationship with the mineralization efficiency were studied. Complete mineralization for the system UV/H2O2/Fe+2 was achieved at: initial H2O2 = 1300mg/L, Fe+2 = 30mg/L, pH=3, temperature =30oC and irradiation time of 60 min, for 300mg/L furfural concentration. The results have shown that the oxidation reagent H2O2 plays a very important role in the furfural mineralization.

  16. Hydrothermal synthesis of bismuth ferrite Fenton-like catalysts and their properties

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Min; Li, Wenjuan, E-mail: liwenjuan2801@163.com; Du, Yong; Kong, Defen; Wang, Ze; Meng, Yi; Sun, Xiaolan; Yan, Tingjiang; Kong, Desheng; You, Jinmao [Qufu Normal University, Shandong Province Key Laboratory of Life-Organic Analysis (China)

    2016-11-15

    Bismuth ferrite, Fenton-like catalysts have been successfully synthesized via simple hydrothermal methods without any templates. Through changing the molar ratio of Bi/Fe, the two main phases BiFeO{sub 3} and Bi{sub 25}FeO{sub 40} can be synthesized under different temperatures. Furthermore, different morphologies of the BiFeO{sub 3} phase can be adjusted by changing different concentrations of HNO{sub 3} and NaOH which were used to dissolve the reactants and adjust the pH values in the prepared process. When the concentration of HNO{sub 3}/NaOH was 8/12 M, some uniform cylindrical bodies with equal height (1 μm) and width (0.6 μm) were obtained, which have not been reported before. The uniform structures exhibited better activities in the photoassisted Fenton-like oxidation process for the degradation of rhodamine B (RhB) under visible light irradiation (420 nm < λ < 800 nm). Through the detection of the degradation mechanism, it showed that the concerted effect of the catalysts and H{sub 2}O{sub 2} can increase the generation of the charge carriers and accelerate the photogenerated charge transfer between the catalysts and dyes. The BiFeO{sub 3} samples also showed magnetic properties at room temperature, which may have potential applications in multiferroic or magnetoelectric sensors and devices.

  17. Preparation of a new Fenton-like catalyst from red mud using molasses wastewater as partial acidifying agent.

    Science.gov (United States)

    Wei, Guangtao; Shao, Luhua; Mo, Jihua; Li, Zhongmin; Zhang, Linye

    2017-06-01

    Using molasses wastewater as partial acidifying agent, a new Fenton-like catalyst (ACRM sm ) was prepared through a simple process of acidification and calcination using red mud as main material. With molasses wastewater, both the free alkali and the chemically bonded alkali in red mud were effectively removed under the action of H 2 SO 4 and molasses wastewater, and the prepared ACRM sm was a near-neutral catalyst. The ACRM sm preparation conditions were as follows: for 3 g of red mud, 9 mL of 0.7 mol/L H 2 SO 4 plus 2 g of molasses wastewater as the acidifying agent, calcination temperature 573 K, and calcination time 1 h. Iron phase of ACRM sm was mainly α-Fe 2 O 3 and trace amount of carbon existed in ACRM sm . The addition of molasses wastewater not only effectively reduced the consumption of H 2 SO 4 in acidification of red mud but also resulted in the generation of carbon and significantly improved the distribution of macropore in prepared ACRM sm . It was found that near-neutral pH of catalyst, generated carbon, and wide distribution of macropore were the main reasons for the high catalytic activity of ACRM sm . The generated carbon and wide distribution of macropore were entirely due to the molasses wastewater added. In degradation of orange II, ACRM sm retained most of its catalytic stability and activity after five recycling times, indicating ACRM sm had an excellent long-term stability in the Fenton-like process. Furthermore, the performance test of settling showed ACRM sm had an excellent settleability. ACRM sm was a safe and green catalytic material used in Fenton-like oxidation for wastewater treatment.

  18. The contributions of the music of George Fenton to the fi lms of Ken Loach

    OpenAIRE

    Sofía López Hernández

    2018-01-01

    Ken Loach is a high profile British film director. Since the mid 1960’s, he has made numerous films for cinema and television. There is already a lot written about his way of filming and yet very little is written about the music for his films. To be able to get inside the music of Ken Loach’s films, we must first talk about George Fenton as he has been Loach’s usual composer since 1994. The object of this article is to fill this gap: to discover what musical characteristics Fenton contri...

  19. Constructing Solid-Gas-Interfacial Fenton Reaction over Alkalinized-C3N4 Photocatalyst To Achieve Apparent Quantum Yield of 49% at 420 nm.

    Science.gov (United States)

    Li, Yunxiang; Ouyang, Shuxin; Xu, Hua; Wang, Xin; Bi, Yingpu; Zhang, Yuanfang; Ye, Jinhua

    2016-10-03

    Efficient generation of active oxygen-related radicals plays an essential role in boosting advanced oxidation process. To promote photocatalytic oxidation for gaseous pollutant over g-C 3 N 4 , a solid-gas interfacial Fenton reaction is coupled into alkalinized g-C 3 N 4 -based photocatalyst to effectively convert photocatalytic generation of H 2 O 2 into oxygen-related radicals. This system includes light energy as power, alkalinized g-C 3 N 4 -based photocatalyst as an in situ and robust H 2 O 2 generator, and surface-decorated Fe 3+ as a trigger of H 2 O 2 conversion, which attains highly efficient and universal activity for photodegradation of volatile organic compounds (VOCs). Taking the photooxidation of isopropanol as model reaction, this system achieves a photoactivity of 2-3 orders of magnitude higher than that of pristine g-C 3 N 4 , which corresponds to a high apparent quantum yield of 49% at around 420 nm. In-situ electron spin resonance (ESR) spectroscopy and sacrificial-reagent incorporated photocatalytic characterizations indicate that the notable photoactivity promotion could be ascribed to the collaboration between photocarriers (electrons and holes) and Fenton process to produce abundant and reactive oxygen-related radicals. The strategy of coupling solid-gas interfacial Fenton process into semiconductor-based photocatalysis provides a facile and promising solution to the remediation of air pollution via solar energy.

  20. Influence of anionic surfactant on the process of electro-Fenton decolorized methyl orange.

    Science.gov (United States)

    Ren, B X

    2010-01-01

    The electro-Fenton process has been shown to be very successful to remove dyes from water. However, the influence of other constituents in dyeing industry wastewater, such as Sodium Dodecyl Sulfate (SDS) surfactants, has not been investigated. In this study, the effect of SDS surfactant on the kinetics of Methyl Orange degradation undergoing Electro-Fenton process was investigated. Results show that Methyl Orange degradation rate decreased as SDS concentration (below Critical Micelle Concentration, CMC) increased, which was attributed to the consumption of hydroxyl radicals (( )OH) by surfactants. The kinetics modeling indicates the reaction was the first-order reaction to Methyl Orange even SDS existing. The pseudo first-order rate constants decreased as SDS concentration increased.