WorldWideScience

Sample records for group displayed significantly

  1. Two distinct groups within the Bacillus subtilis group display significantly different spore heat resistance properties.

    Science.gov (United States)

    Berendsen, Erwin M; Zwietering, Marcel H; Kuipers, Oscar P; Wells-Bennik, Marjon H J

    2015-02-01

    The survival of bacterial spores after heat treatment and the subsequent germination and outgrowth in a food product can lead to spoilage of the food product and economical losses. Prediction of time-temperature conditions that lead to sufficient inactivation requires access to detailed spore thermal inactivation kinetics of relevant model strains. In this study, the thermal inactivation kinetics of spores of fourteen strains belonging to the Bacillus subtilis group were determined in detail, using both batch heating in capillary tubes and continuous flow heating in a micro heater. The inactivation data were fitted using a log linear model. Based on the spore heat resistance data, two distinct groups (p subtilis group could be identified. One group of strains had spores with an average D120 °C of 0.33 s, while the spores of the other group displayed significantly higher heat resistances, with an average D120 °C of 45.7 s. When comparing spore inactivation data obtained using batch- and continuous flow heating, the z-values were significantly different, hence extrapolation from one system to the other was not justified. This study clearly shows that heat resistances of spores from different strains in the B. subtilis group can vary greatly. Strains can be separated into two groups, to which different spore heat inactivation kinetics apply. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Significance of phase-display technique for diagnosis of WPW-Syndrome

    International Nuclear Information System (INIS)

    Mester, J.; Mate, E.; Marosi, G.; Csernay, L.

    1985-01-01

    28 patients with WPW-syndrome were investigated by nuclear cardiology. Phase-display techniques were capable of visualizing and localizing ventricular preexcitations. The prematurely contraction ventricle was diagnosed in 81% of the cases concordant to the results of 12-channel ECG-technique. The control group consisted of 13 LGL-patients and revealed 3 false positives resulting in a specificity of 77%. The results were checked with respect to reproducibility. Additional projections increased the sensitivity of the method. (orig.) [de

  3. The effects of alcohol on the emotional displays of Whites in interracial groups.

    Science.gov (United States)

    Fairbairn, Catharine E; Sayette, Michael A; Levine, John M; Cohn, Jeffrey F; Creswell, Kasey G

    2013-06-01

    Discomfort during interracial interactions is common among Whites in the U.S. and is linked to avoidance of interracial encounters. While the negative consequences of interracial discomfort are well-documented, understanding of its causes is still incomplete. Alcohol consumption has been shown to decrease negative emotions caused by self-presentational concern but increase negative emotions associated with racial prejudice. Using novel behavioral-expressive measures of emotion, we examined the impact of alcohol on displays of discomfort among 92 White individuals interacting in all-White or interracial groups. We used the Facial Action Coding System and comprehensive content-free speech analyses to examine affective and behavioral dynamics during these 36-min exchanges (7.9 million frames of video data). Among Whites consuming nonalcoholic beverages, those assigned to interracial groups evidenced more facial and speech displays of discomfort than those in all-White groups. In contrast, among intoxicated Whites there were no differences in displays of discomfort between interracial and all-White groups. Results highlight the central role of self-presentational concerns in interracial discomfort and offer new directions for applying theory and methods from emotion science to the examination of intergroup relations.

  4. Support for a ban on tobacco powerwalls and other point-of-sale displays: findings from focus groups.

    Science.gov (United States)

    Schmitt, Carol L; Allen, Jane A; Kosa, Katherine M; Curry, Laurel E

    2015-02-01

    This study uses focus group data to document consumer perceptions of powerwall and other point-of-sale (POS) tobacco displays, and support for a ban on tobacco displays. Four focus groups were conducted in 2012 by a trained moderator. The study comprised 34 adult residents of New York State, approximately half with children under age 18 years living at home. Measures used in the study were awareness and perceptions of powerwall and other POS displays, and level of support for a ban on tobacco displays. Analysis focused on perceptions of powerwall and other POS displays, level of support for a ban on tobacco displays and reasons participants oppose a display ban. This study documents a general lack of concern about tobacco use in the community, which does not appear to be associated with support for a ban on POS tobacco displays. Although all participants had seen tobacco powerwalls and most considered them to be a form of advertising, participants were divided as to whether they played a role in youth smoking. Additional research is warranted to determine what factors individuals weigh in assigning value to a ban on POS tobacco displays and other tobacco control policies and how educational efforts can influence those assessments. © The Author 2014. Published by Oxford University Press. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  5. Children's Control/Display Stereotypes.

    Science.gov (United States)

    Hoffmann, Errol R; Chan, Alan H S; Tai, Judy P C

    2018-06-01

    Objective The aim of this study was to determine control/display stereotypes for children of a range of ages and development of these stereotypes with age. Background Little is known about control/display stereotypes for children of different ages and the way in which these stereotypes develop with age. This study is part of a program to determine the need to design differentially for these age groups. Method We tested four groups of children with various tasks (age groups 5 to 7, 8 to 10, 11 to 13, 14 to 16), with about 30 in each group. Examples of common tasks were opening a bottle, turning on taps, and allocating numbers to keypads. More complex tasks involved rotating a control to move a display in a requested direction. Results Tasks with which different age groups were familiar showed no effect of age group. Different control/display arrangements generally showed an increase in stereotype strength with age, with dependence on the form of the control/display arrangement. Two-dimensional arrangements, with the control on the same plane as the display, had higher stereotype strength than three-dimensional arrangements for all age groups, suggesting an effect of familiarity with controls and displays with increasing age. Conclusion Children's control/display stereotypes do not differ greatly from those of adults, and hence, design for children older than 5 years of age, for control/display stereotypes, can be the same as that for adult populations. Application When designing devices for children, the relationship between controls and displays can be as for adult populations, for which there are considerable experimental data.

  6. GROPE-1: a computer display to the sense of feel

    Energy Technology Data Exchange (ETDEWEB)

    Batter, J J; Brooks, Jr, F P

    1972-01-01

    A computer display system was built and programmed that exerts programmable forces on the fingers as one moves a knob in a plane. The system includes a movable carriage, position sensors, mechanisms for converting computer outputs to forces, a visual graphic display, and, most important, the programs. A controlled experiment measured the utility of force output. Two groups were taught topics in elementary field theory and exercised with the computer displays. One group had force displayed to the hand as well as to the eye. The other had visual display only. The experiment was repeated with three different sets of students. The force-display groups performed significantly better in two of the three cases; in the third case, interest in the subject was low and this seems to account for low performance.

  7. Frequency of Gingival Display During Smiling and Comparison of Biometric Measurements in Subjects with and without Gingival Display

    International Nuclear Information System (INIS)

    Khan, F.; Abbas, M.

    2014-01-01

    Objective: To determine the frequency of gingival display during smiling and to compare biometric measurements in subjects with and without gingival display. Study Design: Cross-sectional study. Place and Duration of Study: Department of Prosthodontics, Dr. Ishrat-ul-Ibad Khan Institute of Oral Health Sciences, Dow University of Health Sciences, Karachi, from October 2012 to March 2013. Methodology: A total of 275 subjects (121 men and 154 women) were included in this study. The age of the participants ranged between 21 and 65 years. Measurements were carried out using digital caliper. For each participants, the gingival display was judged as either visible or not. The amounts of horizontal and vertical overlap of anterior teeth were measured using a digital caliper. Gender differences in these parameters and the relationship between subjects showing gingival display when smiling and the two intraoral dental biometric measurements were determined. Statistical analyses of data were performed using SPSS version 17.0 software. The mean scores for gender were calculated and a Student's t-test was used to identify significant differences between both groups. Significant level was set to 0.05. Results: A relatively small percentage of the subjects (37.8%) displayed gingiva when smiling. More women significantly displayed gingiva when smiling than men, with a 2:1 female: male ratio. Women had significantly (p=0.001) more horizontal overlap (3.34 +- 1.45 mm) than men (2.90 +- 1.44 mm), although no significant gender difference were found in vertical overlap. Subjects with gingival display had significantly (p < 0.05) more horizontal (3.49 +- 1.36 mm) and vertical (3.26 +- 1.47 mm) overlap of anterior teeth compared to those who did not display gingiva when smiling. Conclusion: Significantly more women displayed gingiva in smiling. Women had significantly more horizontal overlap than men. No gender differences were recorded between vertical overlap. Subjects who displayed

  8. P values in display items are ubiquitous and almost invariably significant: A survey of top science journals.

    Science.gov (United States)

    Cristea, Ioana Alina; Ioannidis, John P A

    2018-01-01

    P values represent a widely used, but pervasively misunderstood and fiercely contested method of scientific inference. Display items, such as figures and tables, often containing the main results, are an important source of P values. We conducted a survey comparing the overall use of P values and the occurrence of significant P values in display items of a sample of articles in the three top multidisciplinary journals (Nature, Science, PNAS) in 2017 and, respectively, in 1997. We also examined the reporting of multiplicity corrections and its potential influence on the proportion of statistically significant P values. Our findings demonstrated substantial and growing reliance on P values in display items, with increases of 2.5 to 14.5 times in 2017 compared to 1997. The overwhelming majority of P values (94%, 95% confidence interval [CI] 92% to 96%) were statistically significant. Methods to adjust for multiplicity were almost non-existent in 1997, but reported in many articles relying on P values in 2017 (Nature 68%, Science 48%, PNAS 38%). In their absence, almost all reported P values were statistically significant (98%, 95% CI 96% to 99%). Conversely, when any multiplicity corrections were described, 88% (95% CI 82% to 93%) of reported P values were statistically significant. Use of Bayesian methods was scant (2.5%) and rarely (0.7%) articles relied exclusively on Bayesian statistics. Overall, wider appreciation of the need for multiplicity corrections is a welcome evolution, but the rapid growth of reliance on P values and implausibly high rates of reported statistical significance are worrisome.

  9. Statistically significant faunal differences among Middle Ordovician age, Chickamauga Group bryozoan bioherms, central Alabama

    Energy Technology Data Exchange (ETDEWEB)

    Crow, C.J.

    1985-01-01

    Middle Ordovician age Chickamauga Group carbonates crop out along the Birmingham and Murphrees Valley anticlines in central Alabama. The macrofossil contents on exposed surfaces of seven bioherms have been counted to determine their various paleontologic characteristics. Twelve groups of organisms are present in these bioherms. Dominant organisms include bryozoans, algae, brachiopods, sponges, pelmatozoans, stromatoporoids and corals. Minor accessory fauna include predators, scavengers and grazers such as gastropods, ostracods, trilobites, cephalopods and pelecypods. Vertical and horizontal niche zonation has been detected for some of the bioherm dwelling fauna. No one bioherm of those studied exhibits all 12 groups of organisms; rather, individual bioherms display various subsets of the total diversity. Statistical treatment (G-test) of the diversity data indicates a lack of statistical homogeneity of the bioherms, both within and between localities. Between-locality population heterogeneity can be ascribed to differences in biologic responses to such gross environmental factors as water depth and clarity, and energy levels. At any one locality, gross aspects of the paleoenvironments are assumed to have been more uniform. Significant differences among bioherms at any one locality may have resulted from patchy distribution of species populations, differential preservation and other factors.

  10. Scream-embrace displays in wild black-horned capuchin monkeys.

    Science.gov (United States)

    Lynch Alfaro, Jessica

    2008-06-01

    Reintroduction of capuchin monkeys (Cebus apella) into their social group in captivity can elicit sirena screams and embraces. Captive scream-embrace displays are male biased, and females never perform sirena screams. One hypothesis is that scream-embrace displays serve a tension-reduction or reconciliatory function between males with conflicting interests. Alternatively, these displays may function to maintain strong affiliative bonds between friendly male dyads. Scream and/or embrace displays in wild Brazilian black-horned capuchins were analyzed for social and ecological contexts, behavioral components, and individuals involved. Seventy-two displays were observed during the 199-day study period. Among the 66 displays for which both members could be identified by sex, there were 42 occurrences of male-male dyads, 17 of male-female dyads, and seven of female-female dyads. Scream-embrace dyads were male-male pairs significantly more often than expected from group membership, and the alpha male was the only male to engage in scream-embrace displays with females. Female-female pairs did embrace, but never emitted sirena screams. Displays most commonly occurred in "reunion" contexts, primarily the reuniting of subgroups after hours or days out of contact, but also after intergroup encounters, and across groups in "intergroup" displays. Displays were rare, but socially contagious, and subgroup reunions could elicit multiple displays in rapid succession. Although the occurrence of screams and embraces was positively correlated, both behaviors also occurred independently, and their functions may be different. Male sirena screams may be honest advertisements of united alliances, directed toward a third party, whereas the embrace may be a risky affiliative signal, directed primarily within the dyad. Copyright 2008 Wiley-Liss, Inc.

  11. Operant conditioning of facial displays of pain.

    Science.gov (United States)

    Kunz, Miriam; Rainville, Pierre; Lautenbacher, Stefan

    2011-06-01

    The operant model of chronic pain posits that nonverbal pain behavior, such as facial expressions, is sensitive to reinforcement, but experimental evidence supporting this assumption is sparse. The aim of the present study was to investigate in a healthy population a) whether facial pain behavior can indeed be operantly conditioned using a discriminative reinforcement schedule to increase and decrease facial pain behavior and b) to what extent these changes affect pain experience indexed by self-ratings. In the experimental group (n = 29), the participants were reinforced every time that they showed pain-indicative facial behavior (up-conditioning) or a neutral expression (down-conditioning) in response to painful heat stimulation. Once facial pain behavior was successfully up- or down-conditioned, respectively (which occurred in 72% of participants), facial pain displays and self-report ratings were assessed. In addition, a control group (n = 11) was used that was yoked to the reinforcement plans of the experimental group. During the conditioning phases, reinforcement led to significant changes in facial pain behavior in the majority of the experimental group (p .136). Fine-grained analyses of facial muscle movements revealed a similar picture. Furthermore, the decline in facial pain displays (as observed during down-conditioning) strongly predicted changes in pain ratings (R(2) = 0.329). These results suggest that a) facial pain displays are sensitive to reinforcement and b) that changes in facial pain displays can affect self-report ratings.

  12. The effect of rubber flooring on displaying stereotypies in gilts.

    Science.gov (United States)

    Ostović, Mario; Menčik, Sven; Kabalin, Anamaria Ekert; Gračner, Gordana Gregurić; Vučemilo, Marija; Matković, Kristina; Vukičević, Tajana Trbojević; Grahovac, Jurica; Pavičić, Zeljko

    2015-01-01

    The aim of the study was to assess the effect of rubber mats in service unit on displaying stereotypies in gilts. Four 28-day production cycles in all seasons were observed. Each cycle included 28 gilts housed in gestation stalls with slatted concrete floor, which was covered with adjusted mats for 14 gilts (experimental group), while the remaining 14 gilts served as controls. Display of stereotypies and other behaviours observed, mat manipulation and postural behaviours were estimated by direct 1-hour observation of gilts at 2-minute intervals after morning feed supply on days 1, 8, 15 and 28 of each cycle. During the study period, displaying stereotypies was significantly less frequent (P 0.05 all) between the frequency of displaying stereotypies and the frequency of lying and other postures observed, as well as between the stereotypy display and the air temperature. There was no significant correlation (P > 0.05 all) between the frequency of mat manipulation and displaying stereotypies in total or its particular forms, suggesting that the less pronounced stereotypy display in experimental gilts may have been influenced by factors other than those observed in the present study.

  13. Young Children's Responses to Guilt Displays

    Science.gov (United States)

    Vaish, Amrisha; Carpenter, Malinda; Tomasello, Michael

    2011-01-01

    Displaying guilt after a transgression serves to appease the victim and other group members, restore interpersonal relationships, and indicate the transgressors' awareness of and desire to conform to the group's norms. We investigated whether and when young children are sensitive to these functions of guilt displays. In Study 1, after 4- and…

  14. Effect of display location on control-display stereotype strength for translational and rotational controls with linear displays.

    Science.gov (United States)

    Chan, Alan H S; Hoffmann, Errol R

    2015-01-01

    Experiments were designed to investigate the effects of control type and display location, relative to the operator, on the strength of control/display stereotypes. The Worringham and Beringer Visual Field principle and an extension of this principle for rotary controls (Hoffmann E.R., and Chan A.H.S. 2013). "The Worringham and Beringer 'Visual Field' Principle for Rotary Controls. Ergonomics." 56 (10): 1620-1624) indicated that, for a number of different control types (rotary and lever) on different planes, there should be no significant effect of the display location relative to the seated operator. Past data were surveyed and stereotype strengths listed. Experiments filled gaps where data are not available. Six different control types and seven display locations were used, as in the Frame of Reference Transformation Tool (FORT) model of Wickens et al. (Wickens, C.D., Keller, J.W., and Small, R.L. (2010). "Left. No, Right! Development of the Frame of Reference Transformation Tool (FORT)." Proceedings of the Human Factors and Ergonomics Society 54th Annual Meeting September 2010, 54: 1022-1026). Control/display arrangements with high stereotype strengths were evaluated yielding data for designers of complex control/display arrangements where the control and display are in different planes and for where the operator is moving. It was found possible to predict display/control arrangements with high stereotype strength, based on past data. Practitioner Summary: Controls and displays in complex arrangements need to have high compatibility. These experiments provide arrangements for six different controls (rotary and translational) and seven different display locations relative to the operator.

  15. Cooperation during cultural group formation promotes trust towards members of out-groups.

    Science.gov (United States)

    Pan, Xiaofei Sophia; Houser, Daniel

    2013-07-07

    People often cooperate with members of their own group, and discriminate against members of other groups. Previous research establishes that cultural groups can form endogenously, and that these groups demonstrate in-group favouritism. Given the presence of cultural groups, the previous literature argues that cultural evolution selects for groups that exhibit parochial altruism. The source of initial variation in these traits, however, remains uninformed. We show here that a group's economic production environment may substantially influence parochial tendencies, with groups formed around more cooperative production (CP) displaying less parochialism than groups formed around more independent production (IP) processes. Participants randomized into CP and IP production tasks formed cultural groups, and subsequently played hidden-action trust games with in-group and out-group trustees. We found CP to be associated with significantly greater sharing and exchanging behaviours than IP. In trust games, significant parochial altruism (in-group favouritism combined with out-group discrimination) was displayed by members of IP groups. By contrast, members of CP groups did not engage in either in-group favouritism or out-group discrimination. Further, we found the absence of out-group discrimination in CP to persist even following 'betrayal'. Finally, belief data suggest that members of CP are not more intrinsically generous than IP members, but rather more likely to believe that out-group trustees will positively reciprocate. Our results have important implications for anyone interested in building cooperative teams, and shed new light on connections between culture and cooperation.

  16. Consortium for military LCD display procurement

    Science.gov (United States)

    Echols, Gregg

    2002-08-01

    International Display Consortium (IDC) is the joining together of display companies to combined their buying power and obtained favorable terms with a major LCD manufacturer. Consolidating the buying power and grouping the demand enables the rugged display industry of avionics, ground vehicles, and ship based display manufacturers to have unencumbered access to high performance AMLCDs while greatly reducing risk and lowering cost. With an unrestricted supply of AMLCD displays, the consortium members have total control of their risk, cost, deliveries and added value partners. Every display manufacturer desires a very close relationship with a display vender. With IDC each consortium member achieves a close relationship. Consortium members enjoy cost effective access to high performance, industry standard sized LCD panels, and modified commercial displays with 100 degree C clearing points and portrait configurations. Consortium members also enjoy proposal support, technical support and long-term support.

  17. Displays enabling mobile multimedia

    Science.gov (United States)

    Kimmel, Jyrki

    2007-02-01

    With the rapid advances in telecommunications networks, mobile multimedia delivery to handsets is now a reality. While a truly immersive multimedia experience is still far ahead in the mobile world, significant advances have been made in the constituent audio-visual technologies to make this become possible. One of the critical components in multimedia delivery is the mobile handset display. While such alternatives as headset-style near-to-eye displays, autostereoscopic displays, mini-projectors, and roll-out flexible displays can deliver either a larger virtual screen size than the pocketable dimensions of the mobile device can offer, or an added degree of immersion by adding the illusion of the third dimension in the viewing experience, there are still challenges in the full deployment of such displays in real-life mobile communication terminals. Meanwhile, direct-view display technologies have developed steadily, and can provide a development platform for an even better viewing experience for multimedia in the near future. The paper presents an overview of the mobile display technology space with an emphasis on the advances and potential in developing direct-view displays further to meet the goal of enabling multimedia in the mobile domain.

  18. The importance of emotional display rules for employee well-being: A multi-group comparison

    NARCIS (Netherlands)

    Ybema, J.F.; Dam, K. van

    2014-01-01

    'Serving with a smile' has generally been associated with negative effects for employee well-being. The present study investigated whether emotional display rules also relate to positive outcomes by distinguishing demands to suppress negative emotional response (negative display rules) from demands

  19. The importance of emotional display rules for employee well-being : A multi-group comparison

    NARCIS (Netherlands)

    Ybema, Jan Fekke; van Dam, Karen

    2014-01-01

    'Serving with a smile' has generally been associated with negative effects for employee well-being. The present study investigated whether emotional display rules also relate to positive outcomes by distinguishing demands to suppress negative emotional response (negative display rules) from demands

  20. The gender-related differences of nutrient intakes in a group of Italian obese patients display the ongoing transition from Mediterranean to western dietary patterns.

    Science.gov (United States)

    Ricci, Giorgio; Canducci, Edgardo; Guida, Ada; Frascari, Ambra; Rossi, Angelo; Bersani, Gianluca; Ravani, Bruna; Alvisi, Vittorio

    2014-06-01

    The purpose of this study was to compare nutrients and energy intakes between obese women and men and the variation rates over or below the recommended dietary allowances. A retrospective survey was conducted on the records of obese patients, categorized into gender-related groups (36 women, 36 men). Total energy and nutrient intakes were determined. The highest variation rates were found for animal protein, averaging 225 % over the recommended dietary allowance, without significant differences between women and men. The simple carbohydrate intake was quite elevated in women with variations almost 80% over the RDA, significantly higher than in men (22%). The consumption of high-protein foods in both sexes, and even more the association with high-simple carbohydrate foods in women, display the Westernization of traditional eating habits.

  1. Radiologists' preferences for digital mammographic display. The International Digital Mammography Development Group.

    Science.gov (United States)

    Pisano, E D; Cole, E B; Major, S; Zong, S; Hemminger, B M; Muller, K E; Johnston, R E; Walsh, R; Conant, E; Fajardo, L L; Feig, S A; Nishikawa, R M; Yaffe, M J; Williams, M B; Aylward, S R

    2000-09-01

    To determine the preferences of radiologists among eight different image processing algorithms applied to digital mammograms obtained for screening and diagnostic imaging tasks. Twenty-eight images representing histologically proved masses or calcifications were obtained by using three clinically available digital mammographic units. Images were processed and printed on film by using manual intensity windowing, histogram-based intensity windowing, mixture model intensity windowing, peripheral equalization, multiscale image contrast amplification (MUSICA), contrast-limited adaptive histogram equalization, Trex processing, and unsharp masking. Twelve radiologists compared the processed digital images with screen-film mammograms obtained in the same patient for breast cancer screening and breast lesion diagnosis. For the screening task, screen-film mammograms were preferred to all digital presentations, but the acceptability of images processed with Trex and MUSICA algorithms were not significantly different. All printed digital images were preferred to screen-film radiographs in the diagnosis of masses; mammograms processed with unsharp masking were significantly preferred. For the diagnosis of calcifications, no processed digital mammogram was preferred to screen-film mammograms. When digital mammograms were preferred to screen-film mammograms, radiologists selected different digital processing algorithms for each of three mammographic reading tasks and for different lesion types. Soft-copy display will eventually allow radiologists to select among these options more easily.

  2. Dimensions of Situatedness for Digital Public Displays

    Directory of Open Access Journals (Sweden)

    Rui José

    2014-01-01

    Full Text Available Public displays are often strongly situated signs deeply embedded in their physical, social, and cultural setting. Understanding how the display is coupled with on-going situations, its level of situatedness, provides a key element for the interpretation of the displays themselves but is also an element for the interpretation of place, its situated practices, and its social context. Most digital displays, however, do not achieve the same sense of situatedness that seems so natural in their nondigital counterparts. This paper investigates people’s perception of situatedness when considering the connection between public displays and their context. We have collected over 300 photos of displays and conducted a set of analysis tasks involving focus groups and structured interviews with 15 participants. The contribution is a consolidated list of situatedness dimensions that should provide a valuable resource for reasoning about situatedness in digital displays and informing the design and development of display systems.

  3. Using mental rotation to evaluate the benefits of stereoscopic displays

    Science.gov (United States)

    Aitsiselmi, Y.; Holliman, N. S.

    2009-02-01

    Context: The idea behind stereoscopic displays is to create the illusion of depth and this concept could have many practical applications. A common spatial ability test involves mental rotation. Therefore a mental rotation task should be easier if being undertaken on a stereoscopic screen. Aim: The aim of this project is to evaluate stereoscopic displays (3D screen) and to assess whether they are better for performing a certain task than over a 2D display. A secondary aim was to perform a similar study but replicating the conditions of using a stereoscopic mobile phone screen. Method: We devised a spatial ability test involving a mental rotation task that participants were asked to complete on either a 3D or 2D screen. We also design a similar task to simulate the experience on a stereoscopic cell phone. The participants' error rate and response times were recorded. Using statistical analysis, we then compared the error rate and response times of the groups to see if there were any significant differences. Results: We found that the participants got better scores if they were doing the task on a stereoscopic screen as opposed to a 2D screen. However there was no statistically significant difference in the time it took them to complete the task. We also found similar results for 3D cell phone display condition. Conclusions: The results show that the extra depth information given by a stereoscopic display makes it easier to mentally rotate a shape as depth cues are readily available. These results could have many useful implications to certain industries.

  4. A multi-viewer tiled autostereoscopic virtual reality display

    KAUST Repository

    Kooima, Robert; Prudhomme, Andrew; Schulze, Jurgen; Sandin, Daniel; DeFanti, Thomas

    2010-01-01

    Recognizing the value of autostereoscopy for 3D displays in public contexts, we pursue the goal of large-scale, high-resolution, immersive virtual reality using lenticular displays. Our contributions include the scalable tiling of lenticular displays to large fields of view and the use of GPU image interleaving and application optimization for real-time performance. In this context, we examine several ways to improve group-viewing by combining user tracking with multi-view displays. Copyright © 2010 by the Association for Computing Machinery, Inc.

  5. Younger and older adults' perception of the Wundt-Hering illusion as a function of display illumination and reflectance contrast.

    Science.gov (United States)

    Astor-Stetson, E; Lane, S

    1991-08-01

    Reflectance contrast (i.e., black as compared to grey figures on white ground) and display illumination were manipulated to vary the brightness contrast of Wundt-Hering figures. 16 college students and 16 older adults were presented with high, medium, and low reflectance contrast figures. For half the participants, display illumination was manipulated by covering the figures with a .5 yellow neutral density filter. Magnitude of the illusion increased significantly with increased reflectance contrast for college students, and college students were significantly more susceptible to the high contrast figures than were older adults. Display illumination had no effect on the performance of either group.

  6. Focus-Group Evaluation of Nutrition Education Displays by Hispanic Adults Who Live in the USA

    Science.gov (United States)

    Chambers, Delores H.; Munoz, Alejandra M.

    2009-01-01

    Purpose: The purpose of this paper is to examine the acceptability and effectiveness of visual displays of nutrition educational information for low-income Hispanic adults in the USA and to determine whether this population have different perceptions of the same nutrition education displays or express different needs than low-income Caucasian…

  7. Improvements in data display

    International Nuclear Information System (INIS)

    Ellis, G.W.

    1979-01-01

    An analog signal processor is described in this patent for connecting a source of analog signals to a cathode ray tube display in order to extend the dynamic range of the display. This has important applications in the field of computerised X-ray tomography since significant medical information, such as tumours in soft tissue, is often represented by minimal level changes in image density. Cathode ray tube displays are limited to approximately 15 intensity levels. Thus if both strong and weak absorption of the X-rays occurs, the dynamic range of the transmitted signals will be too large to permit small variations to be examined directly on a cathode ray display. Present tomographic image reconstruction methods are capable of quantising X-ray absorption density measurements into 256 or more distinct levels and a description is given of the electronics which enables the upper and lower range of intensity levels to be independently set and continuously varied. (UK)

  8. Drag and drop display & builder

    Energy Technology Data Exchange (ETDEWEB)

    Bolshakov, Timofei B.; Petrov, Andrey D.; /Fermilab

    2007-12-01

    The Drag and Drop (DnD) Display & Builder is a component-oriented system that allows users to create visual representations of data received from data acquisition systems. It is an upgrade of a Synoptic Display mechanism used at Fermilab since 2002. Components can be graphically arranged and logically interconnected in the web-startable Project Builder. Projects can be either lightweight AJAX- and SVG-based web pages, or they can be started as Java applications. The new version was initiated as a response to discussions between the LHC Controls Group and Fermilab.

  9. 3D display system using monocular multiview displays

    Science.gov (United States)

    Sakamoto, Kunio; Saruta, Kazuki; Takeda, Kazutoki

    2002-05-01

    A 3D head mounted display (HMD) system is useful for constructing a virtual space. The authors have researched the virtual-reality systems connected with computer networks for real-time remote control and developed a low-priced real-time 3D display for building these systems. We developed a 3D HMD system using monocular multi-view displays. The 3D displaying technique of this monocular multi-view display is based on the concept of the super multi-view proposed by Kajiki at TAO (Telecommunications Advancement Organization of Japan) in 1996. Our 3D HMD has two monocular multi-view displays (used as a visual display unit) in order to display a picture to the left eye and the right eye. The left and right images are a pair of stereoscopic images for the left and right eyes, then stereoscopic 3D images are observed.

  10. Circular displays: control/display arrangements and stereotype strength with eight different display locations.

    Science.gov (United States)

    Chan, Alan H S; Hoffmann, Errol R

    2015-01-01

    Two experiments are reported that were designed to investigate control/display arrangements having high stereotype strengths when using circular displays. Eight display locations relative to the operator and control were tested with rotational and translational controls situated on different planes according to the Frame of Reference Transformation Tool (FORT) model of Wickens et al. (2010). (Left. No, Right! Development of the Frame of Reference Transformation Tool (FORT), Proceedings of the Human Factors and Ergonomics Society 54th Annual Meeting, 54: 1022-1026). In many cases, there was little effect of display locations, indicating the importance of the Worringham and Beringer (1998. Directional stimulus-response compatibility: a test of three alternative principles. Ergonomics, 41(6), 864-880) Visual Field principle and an extension of this principle for rotary controls (Hoffmann and Chan (2013). The Worringham and Beringer 'visual field' principle for rotary controls. Ergonomics, 56(10), 1620-1624). The initial indicator position (12, 3, 6 and 9 o'clock) had a major effect on control/display stereotype strength for many of the six controls tested. Best display/control arrangements are listed for each of the different control types (rotational and translational) and for the planes on which they are mounted. Data have application where a circular display is used due to limited display panel space and applies to space-craft, robotics operators, hospital equipment and home appliances. Practitioner Summary: Circular displays are often used when there is limited space available on a control panel. Display/control arrangements having high stereotype strength are listed for four initial indicator positions. These arrangements are best for design purposes.

  11. The comparative study of various oral contrast media in 3D display of gastric lesions in spiral CT

    International Nuclear Information System (INIS)

    Wu Dong; Zhou Kangrong; Peng Weijun

    2001-01-01

    Objective: To optimize the oral contrast media in three-dimensional display of gastric lesions. Methods: 41 cases were randomly divided into 3 groups according to different oral contrast media administered: No. 1 air contrast group (n = 17), No. 2 fat emulsion group (n = 7) and No. 3 positive contrast group (n = 25). The 3D CT images were reconstructed using MPR, SSD, RaySum display and virtual endoscopic techniques, and compared with gastric endoscopy and/or conventional barium study. Results: The detectability of gastric lesions using fat emulsion and air contrast was 42.8%(3/7) and 80.0%(20/25), respectively, both were significantly lower than that using positive contrast (100%, 30/30) (x 2 = 19.22, P 2 = 6.60, P 2 = 17.04, P < 0.01). Conclusion: It is very important to choose the appropriate oral contrast media for 3D display of gastric lesions in spiral CT, the positive contrast agent is the optimal choice

  12. End Group Modification

    DEFF Research Database (Denmark)

    Jahnsen, Rasmus O; Sandberg-Schaal, Anne; Frimodt-Møller, Niels

    2015-01-01

    Increased incidence of infections with multidrug-resistant bacterial strains warrants an intensive search for novel potential antimicrobial agents. Here, an antimicrobial peptide analogue with a cationic/hydrophobic alternating design displaying only moderate activity against Gram-positive pathog......Increased incidence of infections with multidrug-resistant bacterial strains warrants an intensive search for novel potential antimicrobial agents. Here, an antimicrobial peptide analogue with a cationic/hydrophobic alternating design displaying only moderate activity against Gram......, the most favorable hydrophobic activity-inducing moieties were found to be cyclohexylacetyl and pentafluorophenylacetyl groups, while the presence of a short PEG-like chain had no significant effect on activity. Introduction of cationic moieties conferred no effect or merely a moderate activity...

  13. Autostereoscopic display technology for mobile 3DTV applications

    Science.gov (United States)

    Harrold, Jonathan; Woodgate, Graham J.

    2007-02-01

    Mobile TV is now a commercial reality, and an opportunity exists for the first mass market 3DTV products based on cell phone platforms with switchable 2D/3D autostereoscopic displays. Compared to conventional cell phones, TV phones need to operate for extended periods of time with the display running at full brightness, so the efficiency of the 3D optical system is key. The desire for increased viewing freedom to provide greater viewing comfort can be met by increasing the number of views presented. A four view lenticular display will have a brightness five times greater than the equivalent parallax barrier display. Therefore, lenticular displays are very strong candidates for cell phone 3DTV. Selection of Polarisation Activated Microlens TM architectures for LCD, OLED and reflective display applications is described. The technology delivers significant advantages especially for high pixel density panels and optimises device ruggedness while maintaining display brightness. A significant manufacturing breakthrough is described, enabling switchable microlenses to be fabricated using a simple coating process, which is also readily scalable to large TV panels. The 3D image performance of candidate 3DTV panels will also be compared using autostereoscopic display optical output simulations.

  14. The effect of display movement angle, indicator type and display location on control/display stereotype strength.

    Science.gov (United States)

    Hoffmann, Errol R; Chan, Alan H S

    2017-08-01

    Much research on stereotype strength relating display and control movements for displays moving in the vertical or horizontal directions has been reported. Here we report effects of display movement angle, where the display moves at angles (relative to the vertical) of between 0° and 180°. The experiment used six different controls, four display locations relative to the operator and three types of indicator. Indicator types were included because of the strong effects of the 'scale-side principle' that are variable with display angle. A directional indicator had higher stereotype strength than a neutral indicator, and showed an apparent reversal in control/display stereotype direction beyond an angle of 90°. However, with a neutral indicator this control reversal was not present. Practitioner Summary: The effects of display moving at angles other than the four cardinal directions, types of control, location of display and types of indicator are investigated. Indicator types (directional and neutral) have an effect on stereotype strength and may cause an apparent control reversal with change of display movement angle.

  15. Electronic displays using optically pumped luminescent semiconductor nanocrystals

    Science.gov (United States)

    Weiss, Shimon [Pinole, CA; Schlamp, Michael C [Plainsboro, NJ; Alivisatos, A Paul [Oakland, CA

    2011-09-27

    A multicolor electronic display is based on an array of luminescent semiconductor nanocrystals. Nanocrystals which emit light of different colors are grouped into pixels. The nanocrystals are optically pumped to produce a multicolor display. Different sized nanocrystals are used to produce the different colors. A variety of pixel addressing systems can be used.

  16. Brief history of electronic stereoscopic displays

    Science.gov (United States)

    Lipton, Lenny

    2012-02-01

    A brief history of recent developments in electronic stereoscopic displays is given concentrating on products that have succeeded in the market place and hence have had a significant influence on future implementations. The concentration is on plano-stereoscopic (two-view) technology because it is now the dominant display modality in the marketplace. Stereoscopic displays were created for the motion picture industry a century ago, and this technology influenced the development of products for science and industry, which in turn influenced product development for entertainment.

  17. Contrast configuration influences grouping in apparent motion.

    Science.gov (United States)

    Ma-Wyatt, Anna; Clifford, Colin W G; Wenderoth, Peter

    2005-01-01

    We investigated whether the same principles that influence grouping in static displays also influence grouping in apparent motion. Using the Ternus display, we found that the proportion of group motion reports was influenced by changes in contrast configuration. Subjects made judgments of completion of these same configurations in a static display. Generally, contrast configurations that induced a high proportion of group motion responses were judged as more 'complete' in static displays. Using a stereo display, we then tested whether stereo information and T-junction information were critical for this increase in group motion. Perceived grouping was consistently higher for same contrast polarity configurations than for opposite contrast polarity configurations, regardless of the presence of stereo information or explicit T-junctions. Thus, while grouping in static and moving displays showed a similar dependence on contrast configuration, motion grouping showed little dependence on stereo or T-junction information.

  18. Clinical significance of changes of serum osteocalcin (BGP) levels in subjects of different age-groups

    International Nuclear Information System (INIS)

    Jiang Lihua; Zhang Jin; Han Cuihua; Ouyang Qiaohong

    2006-01-01

    Objective: To investigate the changes of serum BGP levels in different age-groups. Methods: Serum BGP levels were determined with RIA in 306 subjects of different age-groups. Results: The serum BGP levels were highest in subjects of the pre-adolescent group (age5-15, n=60, vs other groups, all P 50, n=80, P<0.001). Levels in the middle age group were the lowest and were significantly lower than those in the old age group (P<0.001). No sex related differences were observed in the pre-adolescent and middle age groups, but in the youth group, serum BGP levels were significantly higher in the males than those in the females (P<0.05). However, in the old age group, the reverse was true i.e. values being significantly higher in the females (vs males, P<0.01). Conclusion: Serum BGP levels varied greatly among the different age groups. (authors)

  19. Oil defect detection of electrowetting display

    Science.gov (United States)

    Chiang, Hou-Chi; Tsai, Yu-Hsiang; Yan, Yung-Jhe; Huang, Ting-Wei; Mang, Ou-Yang

    2015-08-01

    In recent years, transparent display is an emerging topic in display technologies. Apply in many fields just like mobile device, shopping or advertising window, and etc. Electrowetting Display (EWD) is one kind of potential transparent display technology advantages of high transmittance, fast response time, high contrast and rich color with pigment based oil system. In mass production process of Electrowetting Display, oil defects should be found by Automated Optical Inspection (AOI) detection system. It is useful in determination of panel defects for quality control. According to the research of our group, we proposed a mechanism of AOI detection system detecting the different kinds of oil defects. This mechanism can detect different kinds of oil defect caused by oil overflow or material deteriorated after oil coating or driving. We had experiment our mechanism with a 6-inch Electrowetting Display panel from ITRI, using an Epson V750 scanner with 1200 dpi resolution. Two AOI algorithms were developed, which were high speed method and high precision method. In high precision method, oil jumping or non-recovered can be detected successfully. This mechanism of AOI detection system can be used to evaluate the oil uniformity in EWD panel process. In the future, our AOI detection system can be used in quality control of panel manufacturing for mass production.

  20. The behavioral context of visual displays in common marmosets (Callithrix jacchus).

    Science.gov (United States)

    de Boer, Raïssa A; Overduin-de Vries, Anne M; Louwerse, Annet L; Sterck, Elisabeth H M

    2013-11-01

    Communication is important in social species, and may occur with the use of visual, olfactory or auditory signals. However, visual communication may be hampered in species that are arboreal have elaborate facial coloring and live in small groups. The common marmoset fits these criteria and may have limited visual communication. Nonetheless, some (contradictive) propositions concerning visual displays in the common marmoset have been made, yet quantitative data are lacking. The aim of this study was to assign a behavioral context to different visual displays using pre-post-event-analyses. Focal observations were conducted on 16 captive adult and sub-adult marmosets in three different family groups. Based on behavioral elements with an unambiguous meaning, four different behavioral contexts were distinguished: aggression, fear, affiliation, and play behavior. Visual displays concerned behavior that included facial expressions, body postures, and pilo-erection of the fur. Visual displays related to aggression, fear, and play/affiliation were consistent with the literature. We propose that the visual display "pilo-erection tip of tail" is related to fear. Individuals receiving these fear signals showed a higher rate of affiliative behavior. This study indicates that several visual displays may provide cues or signals of particular social contexts. Since the three displays of fear elicited an affiliative response, they may communicate a request of anxiety reduction or signal an external referent. Concluding, common marmosets, despite being arboreal and living in small groups, use several visual displays to communicate with conspecifics and their facial coloration may not hamper, but actually promote the visibility of visual displays. © 2013 Wiley Periodicals, Inc.

  1. Graphic Display Development Program. Volume II, Revision 0. Appendices

    International Nuclear Information System (INIS)

    1984-12-01

    The objective of this project is to demonstrate the feasibility and utility of developing a set of graphic displays to support symptom-based emergency operating procedures (EOPs). Development of generic graphic displays is based on Revision 3 of the symptomatic Emergency Procedure Guidelines (EPGs) prepared by the BWR Owners' Group (BWROG), and development of plant-specific graphic displays is based on a set of emergency operating procedures developed from these EPGs

  2. Presence and potential significance of aromatic-ketone groups in aquatic humic substances

    Science.gov (United States)

    Leenheer, J.A.; Wilson, M.A.; Malcolm, R.L.

    1987-01-01

    Aquatic humic- and fulvic-acid standards of the International Humic Substances Society were characterized, with emphasis on carbonyl-group nature and content, by carbon-13 nuclear-magnetic-resonance spectroscopy, proton nuclear-magnetic-resonance spectroscopy, and infrared spectroscopy. After comparing spectral results of underivatized humic and fulvic acids with spectral results of chemically modified derivatives, that allow improved observation of the carbonyl group, the data clearly indicated that aromatic ketone groups comprised the majority of the carbonyl-group content. About one ketone group per monocyclic aromatic ring was determined for both humic and fulvic acids. Aromatic-ketone groups were hypothesized to form by photolytic rearrangements and oxidation of phenolic ester and hydrocarbon precursors; these groups have potential significance regarding haloform formation in water, reactivity resulting from active hydrogen of the methyl and methylene adjacent to the ketone groups, and formation of hemiketal and lactol structures. Aromatic-ketone groups also may be the point of attachment between aliphatic and aromatic moieties of aquatic humic-substance structure. ?? 1987.

  3. P3-1: Ophthalmologic Factors Influencing Asthenopia with Watching 3D Displays

    Directory of Open Access Journals (Sweden)

    Sungwook Wee

    2012-10-01

    Full Text Available Purpose: To identify ophthalmologic factors influencing asthenopia while watching 3D displays. Methods: 30 adult subjects without ophthalmologic abnormality watched the same 3D displays for 30 minutes. Each subject's far and near visual acuity, near points of accommodation and convergence, amplitude of fusional convergence and divergence, stereopsis, angle of phoric deviation, tear break-up time, and temperature of ocular surface before and after watching 3D displays were measured. And surveys for subjective symptoms right after watching 3D displays were conducted. The above-mentioned experiments were performed equally with 2D displays for detection of innate influence of 3D displays. Results: The near points of accommodation and convergence were significantly changed after watching 3D displays (p < .05 compared to 2D displays. And all 10 subjective symptoms were significantly increased after watching 3D displays (p < .05. Conclusion: The accommodation and binocular vergence are predominant ophthalmologic factors that might influence asthenopia significantly while watching 3D displays. Subjective visual discomfort significantly increases with watching 3D displays, and more specific evaluation should be added for detecting the practically related factors with asthenopia.

  4. Silicon microelectronic field-emissive devices for advanced display technology

    Science.gov (United States)

    Morse, J. D.

    1993-03-01

    Field-emission displays (FED's) offer the potential advantages of high luminous efficiency, low power consumption, and low cost compared to AMLCD or CRT technologies. An LLNL team has developed silicon-point field emitters for vacuum triode structures and has also used thin-film processing techniques to demonstrate planar edge-emitter configurations. LLNL is interested in contributing its experience in this and other FED-related technologies to collaborations for commercial FED development. At LLNL, FED development is supported by computational capabilities in charge transport and surface/interface modeling in order to develop smaller, low-work-function field emitters using a variety of materials and coatings. Thin-film processing, microfabrication, and diagnostic/test labs permit experimental exploration of emitter and resistor structures. High field standoff technology is an area of long-standing expertise that guides development of low-cost spacers for FEDS. Vacuum sealing facilities are available to complete the FED production engineering process. Drivers constitute a significant fraction of the cost of any flat-panel display. LLNL has an advanced packaging group that can provide chip-on-glass technologies and three-dimensional interconnect generation permitting driver placement on either the front or the back of the display substrate.

  5. Optimizing height presentation for aircraft cockpit displays

    Science.gov (United States)

    Jordan, Chris S.; Croft, D.; Selcon, Stephen J.; Markin, H.; Jackson, M.

    1997-02-01

    This paper describes an experiment conducted to investigate the type of display symbology that most effectively conveys height information to users of head-down plan-view radar displays. The experiment also investigated the use of multiple information sources (redundancy) in the design of such displays. Subjects were presented with eight different height display formats. These formats were constructed from a control, and/or one, two, or three sources of redundant information. The three formats were letter coding, analogue scaling, and toggling (spatially switching the position of the height information from above to below the aircraft symbol). Subjects were required to indicate altitude awareness via a four-key, forced-choice keyboard response. Error scores and response times were taken as performance measures. There were three main findings. First, there was a significant performance advantage when the altitude information was presented above and below the symbol to aid the representation of height information. Second, the analogue scale, a line whose length indicated altitude, proved significantly detrimental to performance. Finally, no relationship was found between the number of redundant information sources employed and performance. The implications for future aircraft and displays are discussed in relation to current aircraft tactical displays and in the context of perceptual psychological theory.

  6. Effect of display type and room illuminance in chest radiographs

    International Nuclear Information System (INIS)

    Liukkonen, Esa; Jartti, Airi; Haapea, Marianne; Oikarinen, Heljae; Ahvenjaervi, Lauri; Mattila, Seija; Nevala, Terhi; Palosaari, Kari; Perhomaa, Marja; Nieminen, Miika T.

    2016-01-01

    To compare diagnostic accuracy in the detection of subtle chest lesions on digital chest radiographs using medical-grade displays, consumer-grade displays, and tablet devices under bright and dim ambient light. Five experienced radiologists independently assessed 50 chest radiographs (32 with subtle pulmonary findings and 18 without apparent findings) under bright (510 lx) and dim (16 lx) ambient lighting. Computed tomography was used as the reference standard for interstitial and nodular lesions and follow-up chest radiograph for pneumothorax. Diagnostic accuracy and sensitivity were calculated for assessments carried out in all displays and compared using the McNemar test. The level of significance was set to p < 0.05. Significant differences in sensitivity between the assessments under bright and dim lighting were found among consumer-grade displays in interstitial opacities with, and in pneumothorax without, Digital Imaging and Communication in Medicine-Grayscale Standard Display Function (DICOM-GSDF) calibration. Compared to 6 megapixel (MP) display under bright lighting, sensitivity in pneumothorax was lower in the tablet device and the consumer-grade display. Sensitivity in interstitial opacities was lower in the DICOM-GSDF calibrated consumer-grade display. A consumer-grade display with or without DICOM-GSDF calibration or a tablet device is not suitable for reading digital chest radiographs in bright lighting. No significant differences were observed between five displays in dim light. (orig.)

  7. A computer graphics display technique for the examination of aircraft design data

    Science.gov (United States)

    Talcott, N. A., Jr.

    1981-01-01

    An interactive computer graphics technique has been developed for quickly sorting and interpreting large amounts of aerodynamic data. It utilizes a graphic representation rather than numbers. The geometry package represents the vehicle as a set of panels. These panels are ordered in groups of ascending values (e.g., equilibrium temperatures). The groups are then displayed successively on a CRT building up to the complete vehicle. A zoom feature allows for displaying only the panels with values between certain limits. The addition of color allows a one-time display thus eliminating the need for a display build up.

  8. Characterization of a multi-seeded (msd) mutant of sorghum that displays significant enhancement in seed number

    Science.gov (United States)

    Sorghum (Sorghum bicolor L. Moench) cultivars and germplasm display branched inflorescence or panicle, characterized by spikelets composed of a single sessile, fertile floret that develop into viable seed and one or two adjacent sterile pedicellate florets (Monoseeded [MSD] trait). Based on total nu...

  9. Policies toward advanced display in the Clinton administration

    Science.gov (United States)

    Hart, Jeffrey A.

    1994-04-01

    The Clinton administration is using its policy toward advanced displays as a test case for making industry-specific policies. They have established a number of criteria for advanced displays that they hope to apply to other industries in the future. For example, they want to support the development of generic technologies through ARPA and NIST, while minimizing the government's role in key business decisions. They want the industry (by which they mean the tool makers, the component assemblers, and the systems firms) to agree internally before they go ahead with their promotional policies. Given the past history of the advanced display industry, especially its disunity in regard to the enforcement of the successful antidumping petition of the Advanced Display Manufacturers Association and to efforts to create the U.S. Display Consortium, these criteria will be hard to meet. Nevertheless, there now appears to be much greater consensus among the three groups than in the past on the need to build indigenous technological capabilities in advanced displays.

  10. Significance of Joint Features Derived from the Modified Group Delay Function in Speech Processing

    Directory of Open Access Journals (Sweden)

    Murthy Hema A

    2007-01-01

    Full Text Available This paper investigates the significance of combining cepstral features derived from the modified group delay function and from the short-time spectral magnitude like the MFCC. The conventional group delay function fails to capture the resonant structure and the dynamic range of the speech spectrum primarily due to pitch periodicity effects. The group delay function is modified to suppress these spikes and to restore the dynamic range of the speech spectrum. Cepstral features are derived from the modified group delay function, which are called the modified group delay feature (MODGDF. The complementarity and robustness of the MODGDF when compared to the MFCC are also analyzed using spectral reconstruction techniques. Combination of several spectral magnitude-based features and the MODGDF using feature fusion and likelihood combination is described. These features are then used for three speech processing tasks, namely, syllable, speaker, and language recognition. Results indicate that combining MODGDF with MFCC at the feature level gives significant improvements for speech recognition tasks in noise. Combining the MODGDF and the spectral magnitude-based features gives a significant increase in recognition performance of 11% at best, while combining any two features derived from the spectral magnitude does not give any significant improvement.

  11. Application of the Decomposition Method to the Design Complexity of Computer-based Display

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyoung Ju; Lee, Seung Woo; Seong, Poong Hyun [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Park, Jin Kyun [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2012-05-15

    The importance of the design of human machine interfaces (HMIs) for human performance and safety has long been recognized in process industries. In case of nuclear power plants (NPPs), HMIs have significant implications for the safety of the NPPs since poor implementation of HMIs can impair the operators' information searching ability which is considered as one of the important aspects of human behavior. To support and increase the efficiency of the operators' information searching behavior, advanced HMIs based on computer technology are provided. Operators in advanced main control room (MCR) acquire information through video display units (VDUs), and large display panel (LDP) required for the operation of NPPs. These computer-based displays contain a very large quantity of information and present them in a variety of formats than conventional MCR. For example, these displays contain more elements such as abbreviations, labels, icons, symbols, coding, and highlighting than conventional ones. As computer-based displays contain more information, complexity of the elements becomes greater due to less distinctiveness of each element. A greater understanding is emerging about the effectiveness of designs of computer-based displays, including how distinctively display elements should be designed. And according to Gestalt theory, people tend to group similar elements based on attributes such as shape, color or pattern based on the principle of similarity. Therefore, it is necessary to consider not only human operator's perception but the number of element consisting of computer-based display

  12. Application of the Decomposition Method to the Design Complexity of Computer-based Display

    International Nuclear Information System (INIS)

    Kim, Hyoung Ju; Lee, Seung Woo; Seong, Poong Hyun; Park, Jin Kyun

    2012-01-01

    The importance of the design of human machine interfaces (HMIs) for human performance and safety has long been recognized in process industries. In case of nuclear power plants (NPPs), HMIs have significant implications for the safety of the NPPs since poor implementation of HMIs can impair the operators' information searching ability which is considered as one of the important aspects of human behavior. To support and increase the efficiency of the operators' information searching behavior, advanced HMIs based on computer technology are provided. Operators in advanced main control room (MCR) acquire information through video display units (VDUs), and large display panel (LDP) required for the operation of NPPs. These computer-based displays contain a very large quantity of information and present them in a variety of formats than conventional MCR. For example, these displays contain more elements such as abbreviations, labels, icons, symbols, coding, and highlighting than conventional ones. As computer-based displays contain more information, complexity of the elements becomes greater due to less distinctiveness of each element. A greater understanding is emerging about the effectiveness of designs of computer-based displays, including how distinctively display elements should be designed. And according to Gestalt theory, people tend to group similar elements based on attributes such as shape, color or pattern based on the principle of similarity. Therefore, it is necessary to consider not only human operator's perception but the number of element consisting of computer-based display

  13. Dichroic Liquid Crystal Displays

    Science.gov (United States)

    Bahadur, Birendra

    The following sections are included: * INTRODUCTION * DICHROIC DYES * Chemical Structure * Chemical and Photochemical Stability * THEORETICAL MODELLING * DEFECTS CAUSED BY PROLONGED LIGHT IRRADIATION * CHEMICAL STRUCTURE AND PHOTOSTABILITY * OTHER PARAMETERS AFFECTING PHOTOSTABILITY * CELL PREPARATION * DICHROIC PARAMETERS AND THEIR MEASUREMENTS * Order Parameter and Dichroic Ratio Of Dyes * Absorbance, Order Parameter and Dichroic Ratio Measurements * IMPACT OF DYE STRUCTURE AND LIQUID CRYSTAL HOST ON PHYSICAL PROPERTIES OF A DICHROIC MIXTURE * Order Parameter and Dichroic Ratio * EFFECT OF LENGTH OF DICHROIC DYES ON THE ORDER PARAMETER * EFFECT OF THE BREADTH OF DYE ON THE ORDER PARAMETER * EFFECT OF THE HOST ON THE ORDER PARAMETER * TEMPERATURE VARIATION OF THE ORDER PARAMETER OF DYES IN A LIQUID CRYSTAL HOST * IMPACT OF DYE CONCENTRATION ON THE ORDER PARAMETER * Temperature Range * Viscosity * Dielectric Constant and Anisotropy * Refractive Indices and Birefringence * solubility43,153-156 * Absorption Wavelength and Auxochromic Groups * Molecular Engineering of Dichroic Dyes * OPTICAL, ELECTRO-OPTICAL AND LIFE PARAMETERS * Colour And CIE Colour space120,160-166 * CIE 1931 COLOUR SPACE * CIE 1976 CHROMATICITY DIAGRAM * CIE UNIFORM COLOUR SPACES & COLOUR DIFFERENCE FORMULAE120,160-166 * Electro-Optical Parameters120 * LUMINANCE * CONTRAST AND CONTRAST RATIO * SWITCHING SPEED * Life Parameters and Failure Modes * DICHROIC MIXTURE FORMULATION * Monochrome Mixture * Black Mixture * ACHROMATIC BLACK MIXTURE FOR HEILMEIER DISPLAYS * Effect of Illuminant on Display Colour * Colour of the Field-On State * Effect of Dye Linewidth * Optimum Centroid Wavelengths * Effect of Dye Concentration * Mixture Formulation Using More Than Three Dyes * ACHROMATIC MIXTURE FOR WHITE-TAYLOR TYPE DISPLAYS * HEILMEIER DISPLAYS * Theoretical Modelling * Threshold Characteristic * Effects of Dye Concentration on Electro-optical Parameters * Effect of Cholesteric Doping * Effect of Alignment

  14. Proximity and physical navigation in collaborative work with a multi-touch wall-display

    DEFF Research Database (Denmark)

    Jakobsen, Mikkel Rønne; Hornbæk, Kasper

    2012-01-01

    Multi-touch, wall-sized displays afford new forms of collaboration. Yet, most data on collaboration with multi-touch displays come from tabletop settings, where users often sit and where space is a limited resource. We study how two-person groups navigate in relation to a 2.8m!1.2m multi-touch di......-touch display with 24.8 megapixels and to each other when solving a sensemaking task on a document collection. The results show that users physically navigate to shift fluently among different parts of the display and between parallel and joint group work....

  15. Developing an integrated digitizing and display surface

    Science.gov (United States)

    Hipple, James D.; Wedding, Daniel K.; Wedding, Donald K., Sr.

    1995-04-01

    The development of an integrated digitizing and display surface, which utilizes touch entry and flat panel display (FPD) technology, is a significant hardware advance in the field of geographic information systems (GIS). Inherent qualities of the FPD, notably the ac gas plasma display, makes such a marriage inevitable. Large diagonal sizes, high resolution color, screen flatness, and monitor thickness are desirable features of an integrated digitizing and display surface. Recently, the GIS literature has addressed a need for such an innovation. The development of graphics displays based on sophisticated technologies include `photorealistic' (or high definition) imaging at resolutions of 2048 X 2048 or greater, palates of 16.7 million colors, formats greater than 30 inches diagonal, and integrated touch entry. In this paper, there is an evaluation of FPDs and data input technologies in the development of such a product.

  16. Procedure and information displays in advanced nuclear control rooms: experimental evaluation of an integrated design.

    Science.gov (United States)

    Chen, Yue; Gao, Qin; Song, Fei; Li, Zhizhong; Wang, Yufan

    2017-08-01

    In the main control rooms of nuclear power plants, operators frequently have to switch between procedure displays and system information displays. In this study, we proposed an operation-unit-based integrated design, which combines the two displays to facilitate the synthesis of information. We grouped actions that complete a single goal into operation units and showed these operation units on the displays of system states. In addition, we used different levels of visual salience to highlight the current unit and provided a list of execution history records. A laboratory experiment, with 42 students performing a simulated procedure to deal with unexpected high pressuriser level, was conducted to compare this design against an action-based integrated design and the existing separated-displays design. The results indicate that our operation-unit-based integrated design yields the best performance in terms of time and completion rate and helped more participants to detect unexpected system failures. Practitioner Summary: In current nuclear control rooms, operators frequently have to switch between procedure and system information displays. We developed an integrated design that incorporates procedure information into system displays. A laboratory study showed that the proposed design significantly improved participants' performance and increased the probability of detecting unexpected system failures.

  17. Injected phage-displayed-VP28 vaccine reduces shrimp Litopenaeus vannamei mortality by white spot syndrome virus infection.

    Science.gov (United States)

    Solís-Lucero, G; Manoutcharian, K; Hernández-López, J; Ascencio, F

    2016-08-01

    White spot syndrome virus (WSSV) is the most important viral pathogen for the global shrimp industry causing mass mortalities with huge economic losses. Recombinant phages are capable of expressing foreign peptides on viral coat surface and act as antigenic peptide carriers bearing a phage-displayed vaccine. In this study, the full-length VP28 protein of WSSV, widely known as potential vaccine against infection in shrimp, was successfully cloned and expressed on M13 filamentous phage. The functionality and efficacy of this vaccine immunogen was demonstrated through immunoassay and in vivo challenge studies. In ELISA assay phage-displayed VP28 was bind to Litopenaeus vannamei immobilized hemocyte in contrast to wild-type M13 phage. Shrimps were injected with 2 × 10(10) cfu animal(-1) single dose of VP28-M13 and M13 once and 48 h later intramuscularly challenged with WSSV to test the efficacy of the vaccine against the infection. All dead challenged shrimps were PCR WSSV-positive. The accumulative mortality of the vaccinated and challenged shrimp groups was significantly lower (36.67%) than the unvaccinated group (66.67%). Individual phenoloxidase and superoxide dismutase activity was assayed on 8 and 48 h post-vaccination. No significant difference was found in those immunological parameters among groups at any sampled time evaluated. For the first time, phage display technology was used to express a recombinant vaccine for shrimp. The highest percentage of relative survival in vaccinated shrimp (RPS = 44.99%) suggest that the recombinant phage can be used successfully to display and deliver VP28 for farmed marine crustaceans. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. European display scene

    Science.gov (United States)

    Bartlett, Christopher T.

    2000-08-01

    The manufacture of Flat Panel Displays (FPDs) is dominated by Far Eastern sources, particularly in Active Matrix Liquid Crystal Displays (AMLCD) and Plasma. The United States has a very powerful capability in micro-displays. It is not well known that Europe has a very active research capability which has lead to many innovations in display technology. In addition there is a capability in display manufacturing of organic technologies as well as the licensed build of Japanese or Korean designs. Finally, Europe has a display systems capability in military products which is world class.

  19. When the display matters: A multifaceted perspective on 3D geovisualizations

    Directory of Open Access Journals (Sweden)

    Juřík Vojtěch

    2017-04-01

    Full Text Available This study explores the influence of stereoscopic (real 3D and monoscopic (pseudo 3D visualization on the human ability to reckon altitude information in noninteractive and interactive 3D geovisualizations. A two phased experiment was carried out to compare the performance of two groups of participants, one of them using the real 3D and the other one pseudo 3D visualization of geographical data. A homogeneous group of 61 psychology students, inexperienced in processing of geographical data, were tested with respect to their efficiency at identifying altitudes of the displayed landscape. The first phase of the experiment was designed as non-interactive, where static 3D visual displayswere presented; the second phase was designed as interactive and the participants were allowed to explore the scene by adjusting the position of the virtual camera. The investigated variables included accuracy at altitude identification, time demands and the amount of the participant’s motor activity performed during interaction with geovisualization. The interface was created using a Motion Capture system, Wii Remote Controller, widescreen projection and the passive Dolby 3D technology (for real 3D vision. The real 3D visual display was shown to significantly increase the accuracy of the landscape altitude identification in non-interactive tasks. As expected, in the interactive phase there were differences in accuracy flattened out between groups due to the possibility of interaction, with no other statistically significant differences in completion times or motor activity. The increased number of omitted objects in real 3D condition was further subjected to an exploratory analysis.

  20. Displays in scintigraphy

    International Nuclear Information System (INIS)

    Todd-Pokropek, A.E.; Pizer, S.M.

    1977-01-01

    Displays have several functions: to transmit images, to permit interaction, to quantitate features and to provide records. The main characteristics of displays used for image transmission are their resolution, dynamic range, signal-to-noise ratio and uniformity. Considerations of visual acuity suggest that the display element size should be much less than the data element size, and in current practice at least 256X256 for a gamma camera image. The dynamic range for image transmission should be such that at least 64 levels of grey (or equivalent) are displayed. Scanner displays are also considered, and in particular, the requirements of a whole-body camera are examined. A number of display systems and devices are presented including a 'new' heated object colour display system. Interaction with displays is considered, including background subtraction, contrast enhancement, position indication and region-of-interest generation. Such systems lead to methods of quantitation, which imply knowledge of the expected distributions. Methods for intercomparing displays are considered. Polaroid displays, which have for so long dominated the field, are in the process of being replaced by stored image displays, now that large cheap memories exist which give an equivalent image quality. The impact of this in nuclear medicine is yet to be seen, but a major effect will be to enable true quantitation. (author)

  1. Technical and radiological image quality comparison of different liquid crystal displays for radiology

    Directory of Open Access Journals (Sweden)

    Dams FE

    2014-10-01

    Full Text Available Francina EM Dams,2 KY Esther Leung,1 Pieter HM van der Valk,2 Marc CJM Kock,2 Jeroen Bosman,1 Sjoerd P Niehof1 1Medical Physics and Technology, 2Department of Radiology, Albert Schweitzer Hospital, Dordrecht, The Netherlands Background: To inform cost-effective decisions in purchasing new medical liquid crystal displays, we compared the image quality in displays made by three manufacturers. Methods: We recruited 19 radiologists and residents to compare the image quality of four liquid crystal displays, including 3-megapixel Barco®, Eizo®, and NEC® displays and a 6-megapixel Barco display. The evaluators were blinded to the manufacturers' names. Technical assessments were based on acceptance criteria and test patterns proposed by the American Association of Physicists in Medicine. Radiological assessments were performed on images from the American Association of Physicists in Medicine Task Group 18. They included X-ray images of the thorax, knee, and breast, a computed tomographic image of the thorax, and a magnetic resonance image of the brain. Image quality was scored on an analog scale (range 0–10. Statistical analysis was performed with repeated-measures analysis of variance. Results: The Barco 3-megapixel display passed all acceptance criteria. The Eizo and NEC displays passed the acceptance criteria, except for the darkest pixel value in the grayscale display function. The Barco 6-megapixel display failed criteria for the maximum luminance response and the veiling glare. Mean radiological assessment scores were 7.8±1.1 (Barco 3-megapixel, 7.8±1.2 (Eizo, 8.1±1.0 (NEC, and 8.1±1.0 (Barco 6-megapixel. No significant differences were found between displays. Conclusion: According to the tested criteria, all the displays had comparable image quality; however, there was a three-fold difference in price between the most and least expensive displays. Keywords: data display, humans, radiographic image enhancement, user-computer interface

  2. Psychophysical analysis of monitor display functions affecting observer diagnostic performance of CT image on liquid crystal display monitors

    International Nuclear Information System (INIS)

    Yamaguchi, M.; Fujita, H.; Asai, Y.; Uemura, M.; Ookura, Y.; Matsumoto, M.; Johkoh, T.

    2005-01-01

    The aim of the present study was to propose suitable display functions for CT image representation on liquid crystal display (LCD) monitors by analyzing the characteristics of the monitor's typical display functions using psychophysical analysis. The luminance of the LCD monitor was adjusted to a maximum of 275 cd/m 2 and 480 cd/m 2 . Three types of postcalibrated display functions (i.e., GSDF, CIELAB, and Exponential γ 2.2) were evaluated. Luminance calculation of a new grayscale test pattern (NGTP) was done for the conversion of the digital driving level (DDL) into the CT value. The psychophysical gradient δ of display functions for the CT value was evaluated and compared via statistical analysis. The δ value of GSDF and CIE decreased exponentially; however, the δ value of Exponential γ 2.2 showed a convex curve with a peak at a specific point. There was a statistically significant difference among the δ values of the three types of display functions on the 480 cd/m 2 maximum via Kruskal Wallis test (P<0.001). The GSDF was suitable for observation of abdominal and lung CT images; however, the display function combined the Exponential γ 2.2 and the GSDF functions and was ideal for observation of brain CT images by psychophysical analysis. (orig.)

  3. Special Technology Area Review on Displays. Report of Department of Defense Advisory Group on Electron Devices Working Group C (Electro-Optics)

    National Research Council Canada - National Science Library

    Turnbach, Susan; Yang, Andrew; Hopper, Darrel G

    2004-01-01

    .... Display research spawns whole new fields as a result of its multidisciplinary nature; for example, the cathode ray tube enabled radar and television and the first commercially successful micro-electro-mechanical system (MEMS...

  4. Monocular display unit for 3D display with correct depth perception

    Science.gov (United States)

    Sakamoto, Kunio; Hosomi, Takashi

    2009-11-01

    A study of virtual-reality system has been popular and its technology has been applied to medical engineering, educational engineering, a CAD/CAM system and so on. The 3D imaging display system has two types in the presentation method; one is a 3-D display system using a special glasses and the other is the monitor system requiring no special glasses. A liquid crystal display (LCD) recently comes into common use. It is possible for this display unit to provide the same size of displaying area as the image screen on the panel. A display system requiring no special glasses is useful for a 3D TV monitor, but this system has demerit such that the size of a monitor restricts the visual field for displaying images. Thus the conventional display can show only one screen, but it is impossible to enlarge the size of a screen, for example twice. To enlarge the display area, the authors have developed an enlarging method of display area using a mirror. Our extension method enables the observers to show the virtual image plane and to enlarge a screen area twice. In the developed display unit, we made use of an image separating technique using polarized glasses, a parallax barrier or a lenticular lens screen for 3D imaging. The mirror can generate the virtual image plane and it enlarges a screen area twice. Meanwhile the 3D display system using special glasses can also display virtual images over a wide area. In this paper, we present a monocular 3D vision system with accommodation mechanism, which is useful function for perceiving depth.

  5. Esthetic effect of the buccal corridor size and amount of tooth-gingival display on smile attractiveness in two student population

    Directory of Open Access Journals (Sweden)

    Hooman Zarif Najafi

    2015-05-01

    Full Text Available 3- Dentist   Background and Aims: An attractive, well-balanced smile is a paramount treatment objective of the modern orthodontic therapy. The purpose of this study was to determine the effects of the buccal corridor size and tooth-gingival display on the smile esthetics as perceived by two groups of the students.   Materials and Methods: A colored image of a woman frontal posed smile was selected. The image was altered digitally to produce different buccal corridor sizes (6%, 12.5% and 20% and different tooth-gingival displays (maxillary central incisors and 2 mm of gingival, maxillary central incisors and dental papilla and 80% of the maxillary central incisors. The different buccal corridor sizes and tooth-gingival displays were combined to produce 9 images. These altered images were rated by 120 medical and dental students using Visual Analogue Scale (VAS. Data were analyzed using Mann-Whitney test, Pairwise comparison LSD test, Repeated measure MANOVA and ICC (Intraclass Correlation Coefficient.   Results: The smile which had the buccal corridor size of 12.5% and complete incisor display without gingival display received the highest rates among the nine smile images in the dental students group. But in the medical students group the smile with the buccal corridor size of 12.5% and 2 mm gingival display, received the highest rates among the nine smile images. There was no significant difference in judging between the male and female raters for the both groups (P>0.05. The dental students were more critical about the increasing of the gingival display.   Conclusion: In the treatment procedure that may lead to the combination of wide buccal corridor and more tooth-gingival show, more caution should be considered.

  6. Evaluation of viewing experiences induced by a curved three-dimensional display

    Science.gov (United States)

    Mun, Sungchul; Park, Min-Chul; Yano, Sumio

    2015-10-01

    Despite an increased need for three-dimensional (3-D) functionality in curved displays, comparisons pertinent to human factors between curved and flat panel 3-D displays have rarely been tested. This study compared stereoscopic 3-D viewing experiences induced by a curved display with those of a flat panel display by evaluating subjective and objective measures. Twenty-four participants took part in the experiments and viewed 3-D content with two different displays (flat and curved 3-D display) within a counterbalanced and within-subject design. For the 30-min viewing condition, a paired t-test showed significantly reduced P300 amplitudes, which were caused by engagement rather than cognitive fatigue, in the curved 3-D viewing condition compared to the flat 3-D viewing condition at P3 and P4. No significant differences in P300 amplitudes were observed for 60-min viewing. Subjective ratings of realness and engagement were also significantly higher in the curved 3-D viewing condition than in the flat 3-D viewing condition for 30-min viewing. Our findings support that curved 3-D displays can be effective for enhancing engagement among viewers based on specific viewing times and environments.

  7. Visual and ocular effects from the use of flat-panel displays

    Directory of Open Access Journals (Sweden)

    Esteban Porcar

    2016-06-01

    Full Text Available AIM: To evaluate the prevalence of eye symptoms in a non-presbyopic population of video display unit (VDU users with flat-panel displays. METHODS: One hundred and sixteen VDU users with flat-panel display from an urban population participated in the study; their ages ranging from 20 to 34y. There were 60 females and 56 males. An eye examination to rule out the presence of significant uncorrected refractive errors, general binocular dysfunctions and eye conditions was carried out. In order to determine and quantify the type and nature of eye symptoms, participants were asked to answer written questionnaire and the results were grouped by gender, age and number of hours a day spent using a VDU. RESULTS: Seventy-two percent of participants reported eye symptoms related to VDU use. Eye symptoms from moderate-to-severe were found in 23% of participants. The main symptom was moderate-to-severe tired eyes (14%; followed by sensitivity to bright lights (12%, blurred vision at far distances (10%, eyestrain or dry eye or irritated or burning eyes (9%, difficulty in refocusing from one distance to another or headache (8% and blurred vision at near or intermediate distances (<4%. Eye symptoms were greater among females (P=0.005 and increased with VDU use, markedly above 6h spent using a VDU in a typical day (P=0.01. CONCLUSION: Significant eye symptoms relate to VDU use often occur and should not be underestimated. The increasing use of electronic devices with flat-panel display should prompt users to take appropriate measures to prevent or to relieve the eye symptoms arising from their use.

  8. Visual and ocular effects from the use of flat-panel displays.

    Science.gov (United States)

    Porcar, Esteban; Pons, Alvaro M; Lorente, Amalia

    2016-01-01

    To evaluate the prevalence of eye symptoms in a non-presbyopic population of video display unit (VDU) users with flat-panel displays. One hundred and sixteen VDU users with flat-panel display from an urban population participated in the study; their ages ranging from 20 to 34y. There were 60 females and 56 males. An eye examination to rule out the presence of significant uncorrected refractive errors, general binocular dysfunctions and eye conditions was carried out. In order to determine and quantify the type and nature of eye symptoms, participants were asked to answer written questionnaire and the results were grouped by gender, age and number of hours a day spent using a VDU. Seventy-two percent of participants reported eye symptoms related to VDU use. Eye symptoms from moderate-to-severe were found in 23% of participants. The main symptom was moderate-to-severe tired eyes (14%); followed by sensitivity to bright lights (12%), blurred vision at far distances (10%), eyestrain or dry eye or irritated or burning eyes (9%), difficulty in refocusing from one distance to another or headache (8%) and blurred vision at near or intermediate distances (<4%). Eye symptoms were greater among females (P=0.005) and increased with VDU use, markedly above 6h spent using a VDU in a typical day (P=0.01). Significant eye symptoms relate to VDU use often occur and should not be underestimated. The increasing use of electronic devices with flat-panel display should prompt users to take appropriate measures to prevent or to relieve the eye symptoms arising from their use.

  9. Investigation of Energy-Efficient Supermarket Display Cases

    Energy Technology Data Exchange (ETDEWEB)

    Walker, D.H.

    2005-01-21

    Supermarkets represent one of the largest energy-intensive building groups in the commercial sector, consuming 2 to 3 million kWh/yr per store (ES-1). Over half of this energy use is for the refrigeration of food display cases and storage coolers. Display cases are used throughout a supermarket for the merchandising of perishable food products. The cases are maintained at air temperatures ranging from -10 to 35 F, depending upon the type of product stored. The operating characteristics and energy requirements of the refrigeration system are directly related to the refrigeration load. The sources of the display case refrigeration load consist of: (1) Moist and warm air infiltration through the open front of the case--air curtains are employed to inhibit this infiltration, but some ambient air is entrained, which adds a substantial portion to the refrigeration load. (2) Heat conduction through case panels and walls. (3) Thermal radiation from the ambient to the product and display case interior. (4) Internal thermal loads--the use of lights, evaporator fans, periodic defrosts, and antisweat heaters adds to the refrigeration load of the display case as well as directly consuming electric energy. The impact of each of these elements on the refrigeration load is very dependent upon case type (Figure ES-1). For example, air infiltration is the most significant portion of the refrigeration load for open, multi-deck cases, while radiation is the largest part of the load for tub-type cases. The door anti-sweat heaters represent a major share of the refrigeration load for frozen food door reach-in cases. Figure ES-2 shows the distribution of display cases in a typical supermarket (ES-2). Open, multi-deck, medium temperature display cases typically comprise about half of the refrigerated fixtures in a store (ES-3). In addition, medium temperature fixtures and storage coolers account for roughly 70 to 75 percent of the total store refrigeration load with open, multi-deck cases

  10. Safety parameter display systems' effect on operator performance

    International Nuclear Information System (INIS)

    Cerven, F.; Ford, R.E.; Blackman, H.S.

    1983-01-01

    Computer generated displays are a powerful and flexible tool for presenting data to the operators of nuclear power plants. Such displays are currently being developed in industry for use as safety parameter displays and for use in advanced control rooms. There exists a need for methods to objectively evaluate the effect of these displays, positive or negative, on the performance of control room personnel. Results of developing one such method, noninteractive simulation, and the two experiments that were performed to determine if it can be used as a method for evaluating computer displays are presented. This method is more objective and powerful than pencil and paper methods because it measures human performance rather than opinion or perference, has excellent control of the experimental variables, and has a higher fidelity to the control room environment. The results of these experiments indicates that the present methodology does not differentiate among the display types tested at a statistically significant level. In other words, all display types tested worked equally well in providing operators needed information

  11. Group tele-immersion:enabling natural interactions between groups at distant sites.

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Christine L. (Sandia National Laboratories, Livermore, CA); Stewart, Corbin (Sandia National Laboratories, Livermore, CA); Nashel, Andrew (University of North Carolina at Chapel Hill, Chapel Hill, NC)

    2005-08-01

    We present techniques and a system for synthesizing views for video teleconferencing between small groups. In place of replicating one-to-one systems for each pair of users, we create a single unified display of the remote group. Instead of performing dense 3D scene computation, we use more cameras and trade-off storage and hardware for computation. While it is expensive to directly capture a scene from all possible viewpoints, we have observed that the participants viewpoints usually remain at a constant height (eye level) during video teleconferencing. Therefore, we can restrict the possible viewpoint to be within a virtual plane without sacrificing much of the realism, and in cloning so we significantly reduce the number of required cameras. Based on this observation, we have developed a technique that uses light-field style rendering to guarantee the quality of the synthesized views, using a linear array of cameras with a life-sized, projected display. Our full-duplex prototype system between Sandia National Laboratories, California and the University of North Carolina at Chapel Hill has been able to synthesize photo-realistic views at interactive rates, and has been used to video conference during regular meetings between the sites.

  12. Partners' Empathy Increases Pain Ratings: Effects of Perceived Empathy and Attachment Style on Pain Report and Display

    Science.gov (United States)

    Hurter, Sarah; Paloyelis, Yannis; de C. Williams, Amanda C.; Fotopoulou, Aikaterini

    2014-01-01

    Pain can be influenced by its social context. We aimed to examine under controlled experimental conditions how empathy from a partner and personal attachment style affect pain report, tolerance, and facial expressions of pain. Fifty-four participants, divided into secure, anxious, and avoidant attachment style groups, underwent a cold pressor task with their partners present. We manipulated how much empathy the participants perceived that their partners had for them. We observed a significant main effect of perceived empathy on pain report, with greater pain reported in the high perceived empathy condition. No such effects were found for pain tolerance or facial display. We also found a significant interaction of empathy with attachment style group, with the avoidant group reporting and displaying less pain than the secure and the anxious groups in the high perceived empathy condition. No such findings were observed in the low empathy condition. These results suggest that empathy from one's partner may influence pain report beyond behavioral reactions. In addition, the amount of pain report and expression that people show in high empathy conditions depends on their attachment style. Perspective Believing that one's partner feels high empathy for one's pain may lead individuals to rate the intensity of pain as higher. Individual differences in attachment style moderate this empathy effect. PMID:24953886

  13. Image Quality Characteristics of Handheld Display Devices for Medical Imaging

    Science.gov (United States)

    Yamazaki, Asumi; Liu, Peter; Cheng, Wei-Chung; Badano, Aldo

    2013-01-01

    Handheld devices such as mobile phones and tablet computers have become widespread with thousands of available software applications. Recently, handhelds are being proposed as part of medical imaging solutions, especially in emergency medicine, where immediate consultation is required. However, handheld devices differ significantly from medical workstation displays in terms of display characteristics. Moreover, the characteristics vary significantly among device types. We investigate the image quality characteristics of various handheld devices with respect to luminance response, spatial resolution, spatial noise, and reflectance. We show that the luminance characteristics of the handheld displays are different from those of workstation displays complying with grayscale standard target response suggesting that luminance calibration might be needed. Our results also demonstrate that the spatial characteristics of handhelds can surpass those of medical workstation displays particularly for recent generation devices. While a 5 mega-pixel monochrome workstation display has horizontal and vertical modulation transfer factors of 0.52 and 0.47 at the Nyquist frequency, the handheld displays released after 2011 can have values higher than 0.63 at the respective Nyquist frequencies. The noise power spectra for workstation displays are higher than 1.2×10−5 mm2 at 1 mm−1, while handheld displays have values lower than 3.7×10−6 mm2. Reflectance measurements on some of the handheld displays are consistent with measurements for workstation displays with, in some cases, low specular and diffuse reflectance coefficients. The variability of the characterization results among devices due to the different technological features indicates that image quality varies greatly among handheld display devices. PMID:24236113

  14. Digital Display Integration Project Project Online 2.0

    International Nuclear Information System (INIS)

    Bardsley, J. N.

    1999-01-01

    transfer; and optimizing techniques to reduce communications bandwidth. Additional topics that will be addressed include: obtaining greater color control; minimization of seam widths in tiled displays; and the human factors that impact the efficient use of high resolution displays. The scope of the project will include both direct-view displays, for use by individuals and small groups, and projection systems for conference rooms and auditoriums

  15. Invisible Display in Aluminum

    DEFF Research Database (Denmark)

    Prichystal, Jan Phuklin; Hansen, Hans Nørgaard; Bladt, Henrik Henriksen

    2005-01-01

    Bang & Olufsen a/s has been working with ideas for invisible integration of displays in metal surfaces. Invisible integration of information displays traditionally has been possible by placing displays behind transparent or semitransparent materials such as plastic or glass. The wish for an integ......Bang & Olufsen a/s has been working with ideas for invisible integration of displays in metal surfaces. Invisible integration of information displays traditionally has been possible by placing displays behind transparent or semitransparent materials such as plastic or glass. The wish...... for an integrated display in a metal surface is often ruled by design and functionality of a product. The integration of displays in metal surfaces requires metal removal in order to clear the area of the display to some extent. The idea behind an invisible display in Aluminum concerns the processing of a metal...

  16. The significance of ethics reflection groups in mental health care: a focus group study among health care professionals.

    Science.gov (United States)

    Hem, Marit Helene; Molewijk, Bert; Gjerberg, Elisabeth; Lillemoen, Lillian; Pedersen, Reidar

    2018-06-05

    Professionals within the mental health services face many ethical dilemmas and challenging situations regarding the use of coercion. The purpose of this study was to evaluate the significance of participating in systematic ethics reflection groups focusing on ethical challenges related to coercion. In 2013 and 2014, 20 focus group interviews with 127 participants were conducted. The interviews were tape recorded and transcribed verbatim. The analysis is inspired by the concept of 'bricolage' which means our approach was inductive. Most participants report positive experiences with participating in ethics reflection groups: A systematic and well-structured approach to discuss ethical challenges, increased consciousness of formal and informal coercion, a possibility to challenge problematic concepts, attitudes and practices, improved professional competence and confidence, greater trust within the team, more constructive disagreement and room for internal critique, less judgmental reactions and more reasoned approaches, and identification of potential for improvement and alternative courses of action. On several wards, the participation of psychiatrists and psychologists in the reflection groups was missing. The impact of the perceived lack of safety in reflection groups should not be underestimated. Sometimes the method for ethics reflection was utilised in a rigid way. Direct involvement of patients and family was missing. This focus group study indicates the potential of ethics reflection groups to create a moral space in the workplace that promotes critical, reflective and collaborative moral deliberations. Future research, with other designs and methodologies, is needed to further investigate the impact of ethics reflection groups on improving health care practices.

  17. Secondary visual workload capability with primary visual and kinesthetic-tactual displays

    Science.gov (United States)

    Gilson, R. D.; Burke, M. W.; Jagacinski, R. J.

    1978-01-01

    Subjects performed a cross-adaptive tracking task with a visual secondary display and either a visual or a quickened kinesthetic-tactual (K-T) primary display. The quickened K-T display resulted in superior secondary task performance. Comparisons of secondary workload capability with integrated and separated visual displays indicated that the superiority of the quickened K-T display was not simply due to the elimination of visual scanning. When subjects did not have to perform a secondary task, there was no significant difference between visual and quickened K-T displays in performing a critical tracking task.

  18. Advanced Colorimetry of Display Systems: Tetra-Chroma3 Display Unit

    Directory of Open Access Journals (Sweden)

    J. Kaiser

    2005-06-01

    Full Text Available High-fidelity color image reproduction is one of the key issues invisual telecommunication systems, for electronic commerce,telemedicine, digital museum and so on. All colorimetric standards ofdisplay systems are up to the present day trichromatic. But, from theshape of a horseshoe-area of all existing colors in the CIE xychromaticity diagram it follows that with three real reproductivelights, the stated area in the CIE xy chromaticity diagram cannot beoverlaid. The expansion of the color gamut of a display device ispossible in a few ways. In this paper, the way of increasing the numberof primaries is studied. The fourth cyan primary is added to threeconventional ones to enlarge the color gamut of reproduction towardscyans and yellow-oranges. The original method of color management forthis new display unit is introduced. In addition, the color gamut ofthe designed additive-based display is successfully compared with thecolor gamut of a modern subtractive-based system. A display with morethan three primary colors is called a multiprimary color display. Thevery advantageous property of such display is the possibility todisplay metameric colors.

  19. Evolution in an autopolyploid group displaying predominantly bivalent pairing at meiosis: genomic similarity of diploid Vaccinium darrowi and autotetraploid V. corymbosum (Ericaceae).

    Science.gov (United States)

    Qu, L; Hancock, J; Whallon, J

    1998-05-01

    The genomic relationship between V. darrowi Camp (2n = 2x = 24) and V. corymbosum L. (2n = 4x = 48) was examined using an interspecific tetraploid hybrid, US 75, and representatives of the parental species. Two features in the background of US 75 led to the prediction that it was an allopolyploid: (1) the parental species are quite distinct morphologically and geographically, and (2) the diploid genome was incorporated into US 75 via an unreduced gamete. However, US 75 recently was shown to display tetrasomic inheritance using molecular markers. In the present cytological study, US 75 was found to have a lower than expected number of multivalents for an autopolyploid, although it had a significantly higher number of quadrivalents than its autotetraploid parent, V. corymbosum. Normal chromosome distributions were observed at anaphase I and II, and pollen viability was high. Our findings suggest that little genomic divergence has developed between the Vaccinium species and that the polyploids may freely exchange genes with sympatric diploid species via unreduced gametes. This pattern of hybridization could be an important component of evolution in all autopolyploid groups, making them much more dynamic than traditionally assumed.

  20. Recent progress in OLED and flexible displays and their potential for application to aerospace and military display systems

    Science.gov (United States)

    Sarma, Kalluri

    2015-05-01

    Organic light emitting diode (OLED) display technology has advanced significantly in recent years and it is increasingly being adapted in consumer electronics products with premium performance, such as high resolution smart phones, Tablet PCs and TVs. Even flexible OLED displays are beginning to be commercialized in consumer electronic devices such as smart phones and smart watches. In addition to the advances in OLED emitters, successful development and adoption of OLED displays for premium performance applications relies on the advances in several enabling technologies including TFT backplanes, pixel drive electronics, pixel patterning technologies, encapsulation technologies and system level engineering. In this paper we will discuss the impact of the recent advances in LTPS and AOS TFTs, R, G, B and White OLED with color filter pixel architectures, and encapsulation, on the success of the OLEDs in consumer electronic devices. We will then discuss potential of these advances in addressing the requirements of OLED and flexible displays for the military and avionics applications.

  1. Microlaser-based displays

    Science.gov (United States)

    Bergstedt, Robert; Fink, Charles G.; Flint, Graham W.; Hargis, David E.; Peppler, Philipp W.

    1997-07-01

    Laser Power Corporation has developed a new type of projection display, based upon microlaser technology and a novel scan architecture, which provides the foundation for bright, extremely high resolution images. A review of projection technologies is presented along with the limitations of each and the difficulties they experience in trying to generate high resolution imagery. The design of the microlaser based projector is discussed along with the advantage of this technology. High power red, green, and blue microlasers have been designed and developed specifically for use in projection displays. These sources, in combination with high resolution, high contrast modulator, produce a 24 bit color gamut, capable of supporting the full range of real world colors. The new scan architecture, which reduces the modulation rate and scan speeds required, is described. This scan architecture, along with the inherent brightness of the laser provides the fundamentals necessary to produce a 5120 by 4096 resolution display. The brightness and color uniformity of the display is excellent, allowing for tiling of the displays with far fewer artifacts than those in a traditionally tiled display. Applications for the display include simulators, command and control centers, and electronic cinema.

  2. It's like a family: the significance attributed by health professionals to diabetes health education groups.

    Science.gov (United States)

    Melo, Lucas Pereira de

    2016-08-01

    This article analyzes the significance that health professionals attribute to health education groups for people with Type 2 Diabetes Mellitus (T2DM). This ethnographic study was developed with five professionals from an Expanded Family Health team that operated in five diabetes health education groups. Information was gathered using participant observations and semi-structured interviews. Data were analyzed by means of a thematic coding technique. Three different categories emerged: (1) It is a way of educating them: groups as an educational and clinical monitoring forum; (2) they know I will be there for them: the groups as a resource to access the health system; and (3) this serves as a self-help group: after all, what purpose does this group serve? The conclusion reached is that the groups studied were a therapy and support hybrid that, by means of their structure, made it possible for the informants (perhaps, also for the patients) to construct other significance for the standardization of health policies and the dilemma of chronicity. Such hybridization made it possible to create outcomes for the specificities of health work in a "total life" context.

  3. Characterizing the reflectivity of handheld display devices.

    Science.gov (United States)

    Liu, Peter; Badano, Aldo

    2014-08-01

    With increased use of handheld and tablet display devices for viewing medical images, methods for consistently measuring reflectivity of the devices are needed. In this note, the authors report on the characterization of diffuse reflections for handheld display devices including mobile phones and tablets using methods recommended by the American Association of Physicists in Medicine Task Group 18 (TG18). The authors modified the diffuse reflectance coefficient measurement method outlined in the TG18 report. The authors measured seven handheld display devices (two phones and five tablets) and three workstation displays. The device was attached to a black panel with Velcro. To study the effect of the back surface on the diffuse reflectance coefficient, the authors created Styrofoam masks with different size square openings and placed it in front of the device. Overall, for each display device, measurements of illuminance and reflected luminance on the display screen were taken. The authors measured with no mask, with masks of varying size, and with display-size masks, and calculated the corresponding diffuse reflectance coefficient. For all handhelds, the diffuse reflectance coefficient measured with no back panel were lower than measurements performed with a mask. The authors found an overall increase in reflectivity as the size of the mask decreases. For workstations displays, diffuse reflectance coefficients were higher when no back panel was used, and higher than with masks. In all cases, as luminance increased, illuminance increased, but not at the same rate. Since the size of handheld displays is smaller than that of workstation devices, the TG18 method suffers from a dependency on illumination condition. The authors show that the diffuse reflection coefficients can vary depending on the nature of the back surface of the illuminating box. The variability in the diffuse coefficient can be as large as 20% depending on the size of the mask. For all measurements

  4. Head Worn Display System for Equivalent Visual Operations

    Science.gov (United States)

    Cupero, Frank; Valimont, Brian; Wise, John; Best. Carl; DeMers, Bob

    2009-01-01

    Head-Worn Displays or so-called, near-to-eye displays have potentially significant advantages in terms of cost, overcoming cockpit space constraints, and for the display of spatially-integrated information. However, many technical issues need to be overcome before these technologies can be successfully introduced into commercial aircraft cockpits. The results of three activities are reported. First, the near-to-eye display design, technological, and human factors issues are described and a literature review is presented. Second, the results of a fixed-base piloted simulation, investigating the impact of near to eye displays on both operational and visual performance is reported. Straight-in approaches were flown in simulated visual and instrument conditions while using either a biocular or a monocular display placed on either the dominant or non-dominant eye. The pilot's flight performance, visual acuity, and ability to detect unsafe conditions on the runway were tested. The data generally supports a monocular design with minimal impact due to eye dominance. Finally, a method for head tracker system latency measurement is developed and used to compare two different devices.

  5. Display Sharing: An Alternative Paradigm

    Science.gov (United States)

    Brown, Michael A.

    2010-01-01

    The current Johnson Space Center (JSC) Mission Control Center (MCC) Video Transport System (VTS) provides flight controllers and management the ability to meld raw video from various sources with telemetry to improve situational awareness. However, maintaining a separate infrastructure for video delivery and integration of video content with data adds significant complexity and cost to the system. When considering alternative architectures for a VTS, the current system's ability to share specific computer displays in their entirety to other locations, such as large projector systems, flight control rooms, and back supporting rooms throughout the facilities and centers must be incorporated into any new architecture. Internet Protocol (IP)-based systems also support video delivery and integration. IP-based systems generally have an advantage in terms of cost and maintainability. Although IP-based systems are versatile, the task of sharing a computer display from one workstation to another can be time consuming for an end-user and inconvenient to administer at a system level. The objective of this paper is to present a prototype display sharing enterprise solution. Display sharing is a system which delivers image sharing across the LAN while simultaneously managing bandwidth, supporting encryption, enabling recovery and resynchronization following a loss of signal, and, minimizing latency. Additional critical elements will include image scaling support, multi -sharing, ease of initial integration and configuration, integration with desktop window managers, collaboration tools, host and recipient controls. This goal of this paper is to summarize the various elements of an IP-based display sharing system that can be used in today's control center environment.

  6. Handbook of display technology

    CERN Document Server

    Castellano, Joseph A

    1992-01-01

    This book presents a comprehensive review of technical and commercial aspects of display technology. It provides design engineers with the information needed to select proper technology for new products. The book focuses on flat, thin displays such as light-emitting diodes, plasma display panels, and liquid crystal displays, but it also includes material on cathode ray tubes. Displays include a large number of products from televisions, auto dashboards, radios, and household appliances, to gasoline pumps, heart monitors, microwave ovens, and more.For more information on display tech

  7. Head-Mounted Display Technology for Low Vision Rehabilitation and Vision Enhancement

    Science.gov (United States)

    Ehrlich, Joshua R.; Ojeda, Lauro V.; Wicker, Donna; Day, Sherry; Howson, Ashley; Lakshminarayanan, Vasudevan; Moroi, Sayoko E.

    2017-01-01

    Purpose To describe the various types of head-mounted display technology, their optical and human factors considerations, and their potential for use in low vision rehabilitation and vision enhancement. Design Expert perspective. Methods An overview of head-mounted display technology by an interdisciplinary team of experts drawing on key literature in the field. Results Head-mounted display technologies can be classified based on their display type and optical design. See-through displays such as retinal projection devices have the greatest potential for use as low vision aids. Devices vary by their relationship to the user’s eyes, field of view, illumination, resolution, color, stereopsis, effect on head motion and user interface. These optical and human factors considerations are important when selecting head-mounted displays for specific applications and patient groups. Conclusions Head-mounted display technologies may offer advantages over conventional low vision aids. Future research should compare head-mounted displays to commonly prescribed low vision aids in order to compare their effectiveness in addressing the impairments and rehabilitation goals of diverse patient populations. PMID:28048975

  8. Solar active region display system

    Science.gov (United States)

    Golightly, M.; Raben, V.; Weyland, M.

    2003-04-01

    The Solar Active Region Display System (SARDS) is a client-server application that automatically collects a wide range of solar data and displays it in a format easy for users to assimilate and interpret. Users can rapidly identify active regions of interest or concern from color-coded indicators that visually summarize each region's size, magnetic configuration, recent growth history, and recent flare and CME production. The active region information can be overlaid onto solar maps, multiple solar images, and solar difference images in orthographic, Mercator or cylindrical equidistant projections. Near real-time graphs display the GOES soft and hard x-ray flux, flare events, and daily F10.7 value as a function of time; color-coded indicators show current trends in soft x-ray flux, flare temperature, daily F10.7 flux, and x-ray flare occurrence. Through a separate window up to 4 real-time or static graphs can simultaneously display values of KP, AP, daily F10.7 flux, GOES soft and hard x-ray flux, GOES >10 and >100 MeV proton flux, and Thule neutron monitor count rate. Climatologic displays use color-valued cells to show F10.7 and AP values as a function of Carrington/Bartel's rotation sequences - this format allows users to detect recurrent patterns in solar and geomagnetic activity as well as variations in activity levels over multiple solar cycles. Users can customize many of the display and graph features; all displays can be printed or copied to the system's clipboard for "pasting" into other applications. The system obtains and stores space weather data and images from sources such as the NOAA Space Environment Center, NOAA National Geophysical Data Center, the joint ESA/NASA SOHO spacecraft, and the Kitt Peak National Solar Observatory, and can be extended to include other data series and image sources. Data and images retrieved from the system's database are converted to XML and transported from a central server using HTTP and SOAP protocols, allowing

  9. Liquid crystal display

    International Nuclear Information System (INIS)

    Takami, K.

    1981-01-01

    An improved liquid crystal display device is described which can display letters, numerals and other necessary patterns in the night time using a minimized amount of radioactive material. To achieve this a self-luminous light source is placed in a limited region corresponding to a specific display area. (U.K.)

  10. INFORMATION DISPLAY: CONSIDERATIONS FOR DESIGNING COMPUTER-BASED DISPLAY SYSTEMS

    International Nuclear Information System (INIS)

    O'HARA, J.M.; PIRUS, D.; BELTRATCCHI, L.

    2004-01-01

    This paper discussed the presentation of information in computer-based control rooms. Issues associated with the typical displays currently in use are discussed. It is concluded that these displays should be augmented with new displays designed to better meet the information needs of plant personnel and to minimize the need for interface management tasks (the activities personnel have to do to access and organize the information they need). Several approaches to information design are discussed, specifically addressing: (1) monitoring, detection, and situation assessment; (2) routine task performance; and (3) teamwork, crew coordination, collaborative work

  11. Strong Military Families Program: A Multifamily Group Approach to Strengthening Family Resilience

    Science.gov (United States)

    Rosenblum, Kate; Muzik, Maria; Waddell, Rachel; Thompson, Stephanie; Rosenberg, Lauren; Masini, Gabriella; Smith, Karen

    2015-01-01

    Military families frequently display remarkable resilience in the face of significant challenges, and yet deployment and parental separation are significant stressors for parents, particularly those with infants and young children. The Strong Military Families preventive intervention is a multifamily parenting and self-care skills group that aims…

  12. High performance visual display for HENP detectors

    CERN Document Server

    McGuigan, M; Spiletic, J; Fine, V; Nevski, P

    2001-01-01

    A high end visual display for High Energy Nuclear Physics (HENP) detectors is necessary because of the sheer size and complexity of the detector. For BNL this display will be of special interest because of STAR and ATLAS. To load, rotate, query, and debug simulation code with a modern detector simply takes too long even on a powerful work station. To visualize the HENP detectors with maximal performance we have developed software with the following characteristics. We develop a visual display of HENP detectors on BNL multiprocessor visualization server at multiple level of detail. We work with general and generic detector framework consistent with ROOT, GAUDI etc, to avoid conflicting with the many graphic development groups associated with specific detectors like STAR and ATLAS. We develop advanced OpenGL features such as transparency and polarized stereoscopy. We enable collaborative viewing of detector and events by directly running the analysis in BNL stereoscopic theatre. We construct enhanced interactiv...

  13. Human isolates of Salmonella enterica serovar Typhimurium from Taiwan displayed significantly higher levels of antimicrobial resistance than those from Denmark.

    Science.gov (United States)

    Torpdahl, Mia; Lauderdale, Tsai-Ling; Liang, Shiu-Yun; Li, Ishien; Wei, Sung-Hsi; Chiou, Chien-Shun

    2013-02-01

    Salmonella enterica serovar Typhimurium is a major zoonotic pathogen with a high prevalence of antimicrobial resistance. This pathogen can disseminate across borders and spread far distances via the food trade and international travel. In this study, we compared the genotypes and antimicrobial resistance of 378 S. Typhimurium isolates collected in Taiwan and Denmark between 2009 and 2010. Genotyping revealed that many S. Typhimurium strains were concurrently circulating in Taiwan, Denmark and other countries in 2009 and 2010. When compared to the isolates collected from Denmark, the isolates from Taiwan displayed a significantly higher level of resistance to 11 of the 12 tested antimicrobials. Seven genetic clusters (A-G) were designated for the isolates. A high percentage of the isolates in genetic clusters C, F and G were multidrug-resistant. Of the isolates in cluster C, 79.2% were ASSuT-resistant, characterized by resistance to ampicillin, streptomycin, sulfamethoxazole, and tetracycline. In cluster F, 84.1% of the isolates were ACSSuT-resistant (resistant to ASSuT and chloramphenicol). Cluster G was unique to Taiwan and characterized in most isolates by the absence of three VNTRs (ST20, ST30 and STTR6) as well as a variety of multidrug resistance profiles. This cluster exhibited very high to extremely high levels of resistance to several first-line drugs, and among the seven clusters, it displayed the highest levels of resistance to cefotaxime and ceftazidime, ciprofloxacin and gentamicin. The high prevalence of antimicrobial resistance in S. Typhimurium from Taiwan highlights the necessity to strictly regulate the use of antimicrobials in the agriculture and human health care sectors. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Natural display mode for digital DICOM-conformant diagnostic imaging.

    Science.gov (United States)

    Peters, Klaus-Ruediger; Ramsby, Gale R

    2002-09-01

    The authors performed this study to investigate the verification of the contrast display properties defined by the digital imaging and communication in medicine (DICOM) PS (picture archiving and communication system [PACS] standard) 3.14-2001 gray-scale display function standard and their dependency on display luminance range and video signal bandwidth. Contrast sensitivity and contrast linearity of DICOM-conformant displays were measured in just-noticeable differences (JNDs) on special perceptual contrast test patterns. Measurements were obtained six times at various display settings under dark room conditions. Display luminance range and video bandwidth had a significant effect on contrast perception. The perceptual promises of the standard could be established only with displays that were calibrated to a unity contrast resolution, at which the number of displayed intensity steps was equal to the number of perceivable contrast steps (JNDs). Such display conditions provide for visual perception information at the level of single-step contrast sensitivity and full-range contrast linearity. These "natural display" conditions also help minimize the Mach banding effects that otherwise reduce contrast sensitivity and contrast linearity. Most, if not all, conventionally used digital display modalities are driven with a contrast resolution larger than 1. Such conditions reduce contrast perception when compared with natural imaging conditions. The DICOM-conformant display conditions at unity contrast resolution were characterized as the "natural display" mode, and, thus, the authors a priori recommend them as being useful for making a primary diagnosis with PACS and teleradiology and as a standard for psychophysical research and performance measurements.

  15. Comparative Analysis of Conventional Electronic and OZ Concept Displays for Aircraft Energy Management

    Science.gov (United States)

    Baker, Erik Reese

    A repeated-measures, within-subjects design was conducted on 58 participant pilots to assess mean differences on energy management situation awareness response time and response accuracy between a conventional electronic aircraft display, a primary flight display (PFD), and an ecological interface design aircraft display, the OZ concept display. Participants were associated with a small Midwestern aviation university, including student pilots, flight instructors, and faculty with piloting experience. Testing consisted of observing 15 static screenshots of each cockpit display type and then selecting applicable responses from 27 standardized responses for each screen. A paired samples t-test was computed comparing accuracy and response time for the two displays. There was no significant difference in means between PFD Response Time and OZ Response Time. On average, mean PFD Accuracy was significantly higher than mean OZ Accuracy (MDiff = 13.17, SDDiff = 20.96), t(57) = 4.78, p performance differences were not operationally remarkable. There was no significant correlation between PFD Response Time and PFD Accuracy, but there was a significant correlation between OZ Response Time and OZ Accuracy, r (58) = .353, p performing as well as experienced professional pilots on dynamic flight tasks with the OZ display. A demographic questionnaire and a feedback survey were included in the trial. An equivalent three-quarters majority of participants rated the PFD as "easy" and the OZ as "confusing", yet performance accuracy and response times between the two displays were not operationally different.

  16. Graphic Data Display from Manufacturing on Web Pages

    Directory of Open Access Journals (Sweden)

    Martin VALAS

    2009-06-01

    Full Text Available Industrial data can by displayed in graphical form which is usually used by three types of users. The first, nonstop users, most frequent operational engineer, who checking actual displayed values and then intervene in operation. The second are occasional users who are interested in historical data e.g. for servicing reason. The last users’ types are tradesmen and managers. State comparison few days or months ago helps as decision-making support. Graph component with web application, which provides data as XML document, was designed for second users group. Graph component displays historical data. Students can fully understand all the problems go along with web application creation in ASP.NET, which provides data in XML document, as well as graph component creation in integrated development environment Flash, thanks in detail described solution using ActionScript.

  17. Liquid Crystal Airborne Display

    Science.gov (United States)

    1977-08-01

    Cum.nings, J. P., et al., Properties and Limitations oe Liquid Crystals for Aircraft Displays, Honeywell Corporate Researc ."I Center, Final Report HR-72...basic module could be used to build displays for both the commercial and military! 157- marhecs, and so would establi sh a broad and sizable market ... market for the display becomes a reality; therein lies, f TABLE 16 THE COURSE OF FUTURE DISPLAY DEVELOPMENT Today 1976-77 1980 1985 Display Size 2" 1 3.2

  18. The evolution of computerized displays in accident management

    International Nuclear Information System (INIS)

    DeBor, J.

    1988-01-01

    Key regulations implemented by the NRC in 1982, which included requirements such as upgraded emergency operating procedures, detailed control room design reviews, the addition of a safety parameter display system, and the inclusion of a degreed shift technical advisor as part of the operating staff, have enabled the use of computerized displays to evolve as an integral part of accident management within each of the four main vendor groups. Problems, however, remain to be resolved in the area of technical content, information reliability, and rules for use in order to achieve the goal of more reliable accident management in nuclear power plants

  19. Evaluating the Effect of Display Realism on Natural Resource Decision Making

    Science.gov (United States)

    Chong, Steven S.

    2018-05-01

    Geographic information systems (GIS) facilitate location-based decision making. Despite the improved availability of GIS software to non-professionals, training in cartographic design has not followed suit. Prior research indicates that when presented with map choices, users are influenced by naïve realism, a preference for realistic displays cotaining irrelevant, extraneous details, leading to decreased task efficiency. This study investigated the role of naïve realism in decision making for natural resource management, a field that often employs geospatial tools. Data was collected through a GIS user ability test, a questionnaire and direct observation. Forty volunteer expert and non-expert resource managers evaluated the suitability of different sites for a land management scenario. Each participant was tested on two map display treatments containing different levels of realism - a simpler 2D display and a more complex 3D display - to compare task performance. Performance was measured by task accuracy and task completion time. User perceptions and preferences about the displays were also recorded. Display realism had an impact on performance and there were indications naïve realism was present. Users completed tasks significantly faster on the 2D display and many individuals misjudged which display they were most accurate or fastest with. The results are informative for designing information systems containing interactive maps, particularly for resource management applications. The results also suggest that the order displays were presented had a significant effect and may have implications for teaching users map-based tasks.

  20. JAVA Stereo Display Toolkit

    Science.gov (United States)

    Edmonds, Karina

    2008-01-01

    This toolkit provides a common interface for displaying graphical user interface (GUI) components in stereo using either specialized stereo display hardware (e.g., liquid crystal shutter or polarized glasses) or anaglyph display (red/blue glasses) on standard workstation displays. An application using this toolkit will work without modification in either environment, allowing stereo software to reach a wider audience without sacrificing high-quality display on dedicated hardware. The toolkit is written in Java for use with the Swing GUI Toolkit and has cross-platform compatibility. It hooks into the graphics system, allowing any standard Swing component to be displayed in stereo. It uses the OpenGL graphics library to control the stereo hardware and to perform the rendering. It also supports anaglyph and special stereo hardware using the same API (application-program interface), and has the ability to simulate color stereo in anaglyph mode by combining the red band of the left image with the green/blue bands of the right image. This is a low-level toolkit that accomplishes simply the display of components (including the JadeDisplay image display component). It does not include higher-level functions such as disparity adjustment, 3D cursor, or overlays all of which can be built using this toolkit.

  1. Modelling impulsive factors for electronics and restaurant coupons’ e-store display

    Science.gov (United States)

    Ariningsih, P. K.; Nainggolan, M.; Sandy, I. A.

    2018-04-01

    In many times, the increment of e-store visitors does not followed by sales increment. Most purchases through e-commerce are impulsive buying, however only small amount of study is available to understand impulsive factors of e-store display. This paper suggests a preliminary concept on understanding the impulsive factors in Electronics and Restaurant Coupons e-store display, which are two among few popular group products sold through e-commerce. By conducting literature study and survey, 31 attributes were identified as impulsive factors in electronics e-store display and 20 attributes were identified as impulsive factors for restaurant coupon e-store. The attributes were then grouped into comprehensive impulsive factors by factor analysis. Each group of impulsive attributes were generated into 3 factors. Accessibility Factors and Trust Factors appeared for each group products. The other factors are Internal Factors for electronics e-store and Marketing factors for restaurant coupons e-store. Structural Equation Model of the impulsive factors was developed for each type of e-store, which stated the covariance between Trust Factors and Accessibility Factors. Based on preliminary model, Internal Factor and Trust Factor are influencing impulsive buying in electronics store. Special factor for electronics e-store is Internal Factor, while for restaurant coupons e-store is Marketing Factor.

  2. Latest development of display technologies

    International Nuclear Information System (INIS)

    Gao Hong-Yue; Yao Qiu-Xiang; Liu Pan; Zheng Zhi-Qiang; Liu Ji-Cheng; Zheng Hua-Dong; Zeng Chao; Yu Ying-Jie; Sun Tao; Zeng Zhen-Xiang

    2016-01-01

    In this review we will focus on recent progress in the field of two-dimensional (2D) and three-dimensional (3D) display technologies. We present the current display materials and their applications, including organic light-emitting diodes (OLEDs), flexible OLEDs quantum dot light emitting diodes (QLEDs), active-matrix organic light emitting diodes (AMOLEDs), electronic paper (E-paper), curved displays, stereoscopic 3D displays, volumetric 3D displays, light field 3D displays, and holographic 3D displays. Conventional 2D display devices, such as liquid crystal devices (LCDs) often result in ambiguity in high-dimensional data images because of lacking true depth information. This review thus provides a detailed description of 3D display technologies. (topical review)

  3. Advances in phage display technology for drug discovery.

    Science.gov (United States)

    Omidfar, Kobra; Daneshpour, Maryam

    2015-06-01

    Over the past decade, several library-based methods have been developed to discover ligands with strong binding affinities for their targets. These methods mimic the natural evolution for screening and identifying ligand-target interactions with specific functional properties. Phage display technology is a well-established method that has been applied to many technological challenges including novel drug discovery. This review describes the recent advances in the use of phage display technology for discovering novel bioactive compounds. Furthermore, it discusses the application of this technology to produce proteins and peptides as well as minimize the use of antibodies, such as antigen-binding fragment, single-chain fragment variable or single-domain antibody fragments like VHHs. Advances in screening, manufacturing and humanization technologies demonstrate that phage display derived products can play a significant role in the diagnosis and treatment of disease. The effects of this technology are inevitable in the development pipeline for bringing therapeutics into the market, and this number is expected to rise significantly in the future as new advances continue to take place in display methods. Furthermore, a widespread application of this methodology is predicted in different medical technological areas, including biosensing, monitoring, molecular imaging, gene therapy, vaccine development and nanotechnology.

  4. Provenance and U-Pb geochronology of the Upper Cretaceous El Chanate Group, northwest Sonora, Mexico, and its tectonic significance

    Science.gov (United States)

    Jacques-Ayala, C.; Barth, A.P.; Wooden, J.L.; Jacobson, C.E.

    2009-01-01

    The Upper Cretaceous El Chanate Group, northwest Sonora, Mexico, is a 2.8km thick clastic sedimentary sequence deposited in a continental basin closely related to volcanic activity. It consists of three formations: the Pozo Duro (oldest), the Anita, and the Escalante (youngest). Petrographic study, conglomerate pebble counts, and U-Pb geochronology of detrital zircons were performed to determine the source and age of this sequence, and to interpret its tectonic setting. In the sandstones of all three formations, the most abundant grains are those of volcanic composition (Q38F22L 40, Q35F19L46, and Q 31F22L47, respectively). The Pozo Duro Formation includes well-rounded quartz-arenite clast conglomerates, whereas conglomerates of the two upper units have clasts predominantly of andesitic and rhyolitic composition. The most likely source for these sediments was the Jurassic volcanic arc exposed in northern Sonora and southern Arizona. Zircons from five sandstone samples define two main age groups, Proterozoic and Mesozoic. The first ranges mostly from 1000 to 1800Ma, which suggests the influence of a cratonic source. This zircon suite is interpreted to be recycled and derived from the same source area as the quartz-rich sandstone clasts in the basal part of the section. Mesozoic zircons range from Triassic to Late Cretaceous, which confirms the proposed Late Cretaceous age for the sequence, and also corroborates Jurassic felsic source rocks. Another possible source was the Alisitos volcanic arc, exposed along the western margin of the Baja California Peninsula. Of regional significance is the great similarity between the El Chanate Group and the McCoy Mountains Formation of southeastern California and southwestern Arizona. Both are Cretaceous, were deposited in continental environments, and have similar zircon-age patterns. Also, both exhibit intense deformation and locally display penetrative foliation. These features strongly suggest that both units underwent

  5. Experience with model based display for advanced diagnostics and control

    International Nuclear Information System (INIS)

    Staffon, J.D.; Lindsay, R.W.

    1989-01-01

    A full color, model based display system based on the Rankine thermodynamic cycle has been developed for use at the Experimental Breeder Reactor II by plant operators, engineers, and experimenters. The displays generate a real time thermodynamic model of the plant processes on computer screens to provide a direct indication of the plant performance. Operators and others who view the displays are no longer required to mentally ''construct'' a model of the process before acting. The model based display accurately depicts the plant states. It appears to effectively reduce the gulf of evaluation, which should result in a significant reduction in human operator errors if this plant display approach is adopted by the nuclear industry. Preliminary comments from users, including operators, indicate an overwhelming acceptance of the display approach. The displays incorporate alarm functions as well as levels of detail ''paging'' capability. The system is developed on a computer network which allows the easy addition of displays as well as extra computers. Constructing a complete console can be rapid and inexpensive. 1 ref., 2 figs

  6. Displays and simulators

    Science.gov (United States)

    Mohon, N.

    A 'simulator' is defined as a machine which imitates the behavior of a real system in a very precise manner. The major components of a simulator and their interaction are outlined in brief form, taking into account the major components of an aircraft flight simulator. Particular attention is given to the visual display portion of the simulator, the basic components of the display, their interactions, and their characteristics. Real image displays are considered along with virtual image displays, and image generators. Attention is given to an advanced simulator for pilot training, a holographic pancake window, a scan laser image generator, the construction of an infrared target simulator, and the Apollo Command Module Simulator.

  7. On Integrity of Flexible Displays

    Science.gov (United States)

    Bouten, Piet C. P.

    Nowadays two display types are dominant in the display market: the bulky cathode ray tube (CRT) and liquid crystal displays (LCD). Both types use glass as substrate material. The LCD display is the dominant player for mobile applications, in for instance mobile phones and portable computers. In the development of displays and their applications a clear interest exists to replace the rigid rectangular display cells by free-shaped, curved or even roll-up cells. These types of applications require flexible displays.

  8. Unsolicited displays of insights

    DEFF Research Database (Denmark)

    Brouwer, Catherine E.

    2015-01-01

    This study is based on videorecorded interactional data from a specific type of institutional setting which consists of a variety of 'language stimulation activities' for bilingual children in Danish preschools. Bilingual children, with a variety of linguistic backgrounds, take part in these acti......This study is based on videorecorded interactional data from a specific type of institutional setting which consists of a variety of 'language stimulation activities' for bilingual children in Danish preschools. Bilingual children, with a variety of linguistic backgrounds, take part...... in these activities in small groups together with a specialized preschool teacher. One pervasive feature of this kind of data is the ongoing orientation to, and guidance from the adult towards the children on what the main business of their interaction is - what they relevantly are doing. In this light, the paper......: Unsolicited displays may lead to side sequences, they may lead to a shift in the main business of the talk, or they may be explicitly or implicitly ignored. The paper discusses whether and how these unsolicited displays of understanding then can be thought of as leading to opportunities for (language...

  9. Book Display as Adult Service

    Directory of Open Access Journals (Sweden)

    Matthew S. Moore

    1997-03-01

    Full Text Available 無Book display as an adult service is defined as choosing and positioning adult books from the collection to increase their circulation. The author contrasts bookstore arrangement for sales versus library arrangement for access. The paper considers the library-as-a-whole as a display, examines the right size for an in-library display, and discusses mass displays, end-caps, on-shelf displays, and the Tiffany approach. The author proposes that an effective display depends on an imaginative, unifying theme, and that book displays are part of the joy of libraries.

  10. Pseudo-random arranged color filter array for controlling moiré patterns in display.

    Science.gov (United States)

    Zhou, Yangui; Fan, Hang; An, Sengzhong; Li, Juntao; Wang, Jiahui; Zhou, Jianying; Liu, Yikun

    2015-11-16

    Optical display quality can be degraded by the appearance of moiré pattern occurring in a display system consisting of a basic matrix superimposed with a functional structured optical layer. We propose in this paper a novel pseudo-random arranged color filter array with the table number arranged with an optimal design scenario. We show that the moiré pattern can be significantly reduced with the introduction of the special color filter array. The idea is tested with an experiment that gives rise to a substantially reduced moiré pattern in a display system. It is believed that the novel functional optical structures have significant impact to complex structured display system in general and to the autostereoscopic and integrated display systems in particular.

  11. Preferred viewing distance and screen angle of electronic paper displays.

    Science.gov (United States)

    Shieh, Kong-King; Lee, Der-Song

    2007-09-01

    This study explored the viewing distance and screen angle for electronic paper (E-Paper) displays under various light sources, ambient illuminations, and character sizes. Data analysis showed that the mean viewing distance and screen angle were 495 mm and 123.7 degrees. The mean viewing distances for Kolin Chlorestic Liquid Crystal display was 500 mm, significantly longer than Sony electronic ink display, 491 mm. Screen angle for Kolin was 127.4 degrees, significantly greater than that of Sony, 120.0 degrees. Various light sources revealed no significant effect on viewing distances; nevertheless, they showed significant effect on screen angles. The screen angle for sunlight lamp (D65) was similar to that of fluorescent lamp (TL84), but greater than that of tungsten lamp (F). Ambient illumination and E-paper type had significant effects on viewing distance and screen angle. The higher the ambient illumination was, the longer the viewing distance and the lesser the screen angle. Character size had significant effect on viewing distances: the larger the character size, the longer the viewing distance. The results of this study indicated that the viewing distance for E-Paper was similar to that of visual display terminal (VDT) at around 500 mm, but greater than normal paper at about 360 mm. The mean screen angle was around 123.7 degrees, which in terms of viewing angle is 29.5 degrees below horizontal eye level. This result is similar to the general suggested viewing angle between 20 degrees and 50 degrees below the horizontal line of sight.

  12. Intrapartum caesarean rates differ significantly between ethnic groups--relationship to induction.

    LENUS (Irish Health Repository)

    Ismail, Khadijah I

    2012-01-31

    OBJECTIVE: Given international variation in obstetric practices and outcomes, comparison of labour outcomes in different ethnic groups could provide important information regarding the underlying reasons for rising caesarean delivery rates. Increasing numbers of women from Eastern European countries are now delivering in Irish maternity hospitals. We compared labour outcomes between Irish and Eastern European (EE) women in a large tertiary referral center. STUDY DESIGN: This was a prospective consecutive cohort study encompassing a single calendar year. The cohort comprised 5550 Irish and 867 EE women delivered in a single institution in 2009. Women who had multiple pregnancies, breech presentation, and elective or pre-labour caesarean sections (CS) were excluded. Data obtained from birth registers included maternal age, nationality, parity, gestation, onset of labour, mode of delivery and birth weight. RESULTS: The overall intrapartum CS rate was 11.4% and was significantly higher in Irish compared to EE women (11.8% vs. 8.8%; p=0.008). The proportion of primiparas was lower in Irish compared to EE women (44.8% vs. 63.6%; p<0.0001). The intrapartum CS rate was almost doubled in Irish compared to EE primiparas (20.7% vs. 11.0%; p<0.0001). Analysis of primiparas according to labour onset revealed a higher intrapartum CS rate in Irish primiparas in both spontaneous (13.5% vs. 7.2%; p<0.0001) and induced labour (29.5% vs. 19.3%; p=0.005). Irish women were older with 19.7% of primiparas aged more than 35, compared to 1.6% of EE women (p<0.0001). The primigravid CS rate in Irish women was significantly higher in women aged 35 years or older compared women aged less than 35 (30.6% vs. 18.3%; p<0.0001) consistent in both spontaneous and induced labour. The primiparous induction rate was 45.4% in Irish women compared to 32% in EE women, and more Irish women were induced before 41 weeks gestation. CONCLUSION: The results highlight that primigravid intrapartum CS rates were

  13. Sexpectations: male college students' views about displayed sexual references on females' social networking web sites.

    Science.gov (United States)

    Moreno, Megan A; Swanson, Michael J; Royer, Heather; Roberts, Linda J

    2011-04-01

    Sexual reference display on a social networking web site (SNS) is associated with self-reported sexual intention; females are more likely to display sexually explicit content on SNSs. The purpose of this study was to investigate male college students' views towards sexual references displayed on publicly available SNSs by females. Focus groups. One large state university. Male college students age 18-23. All tape recorded discussion was fully transcribed, then discussed to determine thematic consensus. A trained male facilitator asked participants about views on sexual references displayed on SNSs by female peers and showed examples of sexual references from female's SNS profiles to facilitate discussion. A total of 28 heterosexual male participants participated in seven focus groups. Nearly all participants reported using Facebook to evaluate potential female partners. Three themes emerged from our data. First, participants reported that displays of sexual references on social networking web sites increased sexual expectations. Second, sexual reference display decreased interest in pursuing a dating relationship. Third, SNS data was acknowledged as imperfect but valuable. Females who display sexual references on publicly available SNS profiles may be influencing potential partners' sexual expectations and dating intentions. Future research should examine females' motivations and beliefs about displaying such references and educate women about the potential impact of these sexual displays. Copyright © 2011 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.

  14. Cholesteric Liquid Crystal Based Reflex Color Reflective Displays

    Science.gov (United States)

    Khan, Asad

    2012-02-01

    Bistable color cholesteric liquid crystal displays are unique LCDs that exhibit high reflectivity, good contrast, extremely low power operation, and are amenable to versatile roll-to-roll manufacturing. The display technology, now branded as Reflex has been in commercialized products since 1996. It has been the subject of extensive research and development globally by a variety of parties in both academic and industrial settings. Today, the display technology is in volume production for applications such as dedicated eWriters (Boogie Board), full color electronic skins (eSkin), and displays for smart cards. The flexibility comes from polymerization induced phase separation using unique materials unparalleled in any other display technology. The blend of monomers, polymers, cross linkers, and other components along with nematic liquid crystals and chiral dopants is created and processed in such ways so as to enable highly efficient manufactrable displays using ultra thin plastic substrates -- often as thin as 50μm. Other significant aspects include full color by stacking or spatial separation, night vision capability, ultra high resolution, as well as active matrix capabilities. Of particular note is the stacking approach of Reflex based displays to show full color. This approach for reflective color displays is unique to this technology. Owing to high transparency in wavelength bands outside the selective reflection band, three primarily color layers can be stacked on top of each other and reflect without interfering with other layers. This highly surprising architecture enables the highest reflectivity of any other reflective electronic color display technology. The optics, architecture, electro-topics, and process techniques will be discussed. This presentation will focus on the physics of the core technology and color, it's evolution from rigid glass based displays to flexible displays, development of products from the paradigm shifting concepts to consumer

  15. The influence of lip form on incisal display with lips in repose on the esthetic preferences of dentists and lay people.

    Science.gov (United States)

    Kim, Jee; Topolski, Richard; Dickinson, Douglas; Ramos, Van

    2017-09-01

    Information is lacking for viewer preferences for incisal display with lips in repose. The purpose of this online survey was to establish measurement parameters to classify and define a lip form and to evaluate the influence of lip form on dentists' and laypersons' preferences for the amount of incisal display with lips in repose. Computer-generated male and female models were created using 3 different lip forms each, straight, moderate, and high. Three images of these models (frontal full face, zoomed-in frontal around the mouth, and oblique zoomed-in image of the mouth) were arranged in an interactive survey that was disseminated on the Websites Facebook, Instagram, DentalTown and by word-of-mouth. Respondents manipulated the incisal display of all 3 images in unison, using a slide bar, and the resulting incisal display was measured in millimeters and served as the primary dependent measure. Survey demographic data were obtained from an online survey site. Data were assessed for skewness, kurtosis, and outliers and analyzed with 5-way ANOVA: 2 sex levels for model, 2 levels for sex of respondent, 3 levels for lip height, 3 levels for occupation, and 5 levels of ethnicity, with multiple comparisons corrected with Bonferroni adjustments and post hoc comparisons performed using the Scheffé test (α=.05 for all comparisons). A total of 1039 individuals consented to the study. A final sample size of 687 respondents was obtained after excluding 352 who failed to complete the survey. The results indicated that lip form affected the esthetic perception of incisal display significantly (P<.001), with a preference for a greater amount of incisal display corresponding with increasing lip forms. Sex of the model was also significant, with greater incisal display being preferred for female faces. A significant difference was found for respondents' ethnicity, with African Americans generally preferring smaller incisal displays than other ethnic groups. No other main effects

  16. Simulated laparoscopy using a head-mounted display vs traditional video monitor: an assessment of performance and muscle fatigue.

    Science.gov (United States)

    Maithel, S K; Villegas, L; Stylopoulos, N; Dawson, S; Jones, D B

    2005-03-01

    The direction of visual gaze may be an important ergonomic factor that affects operative performance. We designed a study to determine whether a head-mounted display (HMD) worn by the surgeon would improve task performance and/or reduce muscle fatigue during a laparoscopic task when compared to the use of a traditional video monitor display (VMD). Surgical residents (n = 30) were enrolled in the study. A junior group, consisting of 15 postgraduate year (PGY) = 1 subjects with no previous laparoscopic experience, and a senior group, consisting of 15 PGY 4 and PGY 5 subjects with experience, completed a laparoscopic task that was repeated four times using the Computer Enhanced Laparoscopic Training System (CELTS). Groups alternated between using the HMD with the task placed in a downward frontal position and the VMD with the task at a 30 degrees lateral angle. The CELTS module assessed task completion time, depth perception, path length of instruments, response orientation, motion smoothness; the system then generated an overall score. Electromyography (EMG) was used to record sternocleidomastoid muscle activity. Display preference was surveyed. The senior residents performed better than the junior residents overall on all parameters (p < 0.05) except for motion smoothness, where there was no difference. In both groups, the HMD significantly improved motion smoothness when compared to the VMD (p < 0.05). All other parameters were equal. There was less muscle fatigue when using the VMD (p < 0.05). We found that 66% of the junior residents but only 20% of the senior residents preferred the HMD. The CELTS module demonstrated evidence of construct validity by differentiating the performances of junior and senior residents. By aligning the surgeon's visual gaze with the instruments, HMD improved smoothness of motion. Experienced residents preferred the traditional monitor display. Although the VMD produced less muscle fatigue, inexperienced residents preferred the HMD

  17. Augmenting digital displays with computation

    Science.gov (United States)

    Liu, Jing

    As we inevitably step deeper and deeper into a world connected via the Internet, more and more information will be exchanged digitally. Displays are the interface between digital information and each individual. Naturally, one fundamental goal of displays is to reproduce information as realistically as possible since humans still care a lot about what happens in the real world. Human eyes are the receiving end of such information exchange; therefore it is impossible to study displays without studying the human visual system. In fact, the design of displays is rather closely coupled with what human eyes are capable of perceiving. For example, we are less interested in building displays that emit light in the invisible spectrum. This dissertation explores how we can augment displays with computation, which takes both display hardware and the human visual system into consideration. Four novel projects on display technologies are included in this dissertation: First, we propose a software-based approach to driving multiview autostereoscopic displays. Our display algorithm can dynamically assign views to hardware display zones based on multiple observers' current head positions, substantially reducing crosstalk and stereo inversion. Second, we present a dense projector array that creates a seamless 3D viewing experience for multiple viewers. We smoothly interpolate the set of viewer heights and distances on a per-vertex basis across the arrays field of view, reducing image distortion, crosstalk, and artifacts from tracking errors. Third, we propose a method for high dynamic range display calibration that takes into account the variation of the chrominance error over luminance. We propose a data structure for enabling efficient representation and querying of the calibration function, which also allows user-guided balancing between memory consumption and the amount of computation. Fourth, we present user studies that demonstrate that the ˜ 60 Hz critical flicker fusion

  18. Rapid visual grouping and figure-ground processing using temporally structured displays.

    Science.gov (United States)

    Cheadle, Samuel; Usher, Marius; Müller, Hermann J

    2010-08-23

    We examine the time course of visual grouping and figure-ground processing. Figure (contour) and ground (random-texture) elements were flickered with different phases (i.e., contour and background are alternated), requiring the observer to group information within a pre-specified time window. It was found this grouping has a high temporal resolution: less than 20ms for smooth contours, and less than 50ms for line conjunctions with sharp angles. Furthermore, the grouping process takes place without an explicit knowledge of the phase of the elements, and it requires a cumulative build-up of information. The results are discussed in relation to the neural mechanism for visual grouping and figure-ground segregation. Copyright 2010 Elsevier Ltd. All rights reserved.

  19. Display of adenoregulin with a novel Pichia pastoris cell surface display system.

    Science.gov (United States)

    Ren, Ren; Jiang, Zhengbing; Liu, Meiyun; Tao, Xinyi; Ma, Yushu; Wei, Dongzhi

    2007-02-01

    Two Pichia pastoris cell surface display vectors were constructed. The vectors consisted of the flocculation functional domain of Flo1p with its own secretion signal sequence or the alpha-factor secretion signal sequence, a polyhistidine (6xHis) tag for detection, an enterokinase recognition site, and the insertion sites for target proteins. Adenoregulin (ADR) is a 33-amino-acid antimicrobial peptide isolated from Phyllomedusa bicolor skin. The ADR was expressed and displayed on the Pichia pastoris KM71 cell surface with the system reported. The displayed recombinant ADR fusion protein was detected by fluorescence microscopy and confocal laser scanning microscopy (CLSM). The antimicrobial activity of the recombinant adenoregulin was detected after proteolytic cleavage of the fusion protein on cell surface. The validity of the Pichia pastoris cell surface display vectors was proved by the displayed ADR.

  20. Do Children and Adolescents with Anorexia Nervosa Display an Inefficient Cognitive Processing Style?

    Directory of Open Access Journals (Sweden)

    Katie Lang

    Full Text Available This study aimed to examine neuropsychological processing in children and adolescents with Anorexia Nervosa (AN. The relationship of clinical and demographic variables to neuropsychological functioning within the AN group was also explored.The performance of 41 children and adolescents with a diagnosis of AN were compared to 43 healthy control (HC participants on a number of neuropsychological measures.There were no differences in IQ between AN and HC groups. However, children and adolescents with AN displayed significantly more perseverative errors on the Wisconsin Card Sorting Test, and lower Style and Central Coherence scores on the Rey Osterrieth Complex Figure Test relative to HCs.Inefficient cognitive processing in the AN group was independent of clinical and demographic variables, suggesting it might represent an underlying trait for AN. The implications of these findings are discussed.

  1. Flat panel display - Impurity doping technology for flat panel displays

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Toshiharu [Advanced Technology Planning, Sumitomo Eaton Nova Corporation, SBS Tower 9F, 10-1, Yoga 4-chome, Setagaya-ku, 158-0097 Tokyo (Japan)]. E-mail: suzuki_tsh@senova.co.jp

    2005-08-01

    Features of the flat panel displays (FPDs) such as liquid crystal display (LCD) and organic light emitting diode (OLED) display, etc. using low temperature poly-Si (LTPS) thin film transistors (TFTs) are briefly reviewed comparing with other FPDs. The requirements for fabricating TFTs used for high performance FPDs and system on glass (SoG) are addressed. This paper focuses on the impurity doping technology, which is one of the key technologies together with crystallization by laser annealing, formation of high quality gate insulator and gate-insulator/poly-Si interface. The issues to be solved in impurity doping technology for state of the art and future TFTs are clarified.

  2. Flat panel display - Impurity doping technology for flat panel displays

    International Nuclear Information System (INIS)

    Suzuki, Toshiharu

    2005-01-01

    Features of the flat panel displays (FPDs) such as liquid crystal display (LCD) and organic light emitting diode (OLED) display, etc. using low temperature poly-Si (LTPS) thin film transistors (TFTs) are briefly reviewed comparing with other FPDs. The requirements for fabricating TFTs used for high performance FPDs and system on glass (SoG) are addressed. This paper focuses on the impurity doping technology, which is one of the key technologies together with crystallization by laser annealing, formation of high quality gate insulator and gate-insulator/poly-Si interface. The issues to be solved in impurity doping technology for state of the art and future TFTs are clarified

  3. Handbook of Visual Display Technology

    CERN Document Server

    Cranton, Wayne; Fihn, Mark

    2012-01-01

    The Handbook of Visual Display Technology is a unique work offering a comprehensive description of the science, technology, economic and human interface factors associated with the displays industry. An invaluable compilation of information, the Handbook will serve as a single reference source with expert contributions from over 150 international display professionals and academic researchers. All classes of display device are covered including LCDs, reflective displays, flexible solutions and emissive devices such as OLEDs and plasma displays, with discussion of established principles, emergent technologies, and particular areas of application. The wide-ranging content also encompasses the fundamental science of light and vision, image manipulation, core materials and processing techniques, display driving and metrology.

  4. Polymer Dispersed Liquid Crystal Displays

    Science.gov (United States)

    Doane, J. William

    The following sections are included: * INTRODUCTION AND HISTORICAL DEVELOPMENT * PDLC MATERIALS PREPARATION * Polymerization induced phase separation (PIPS) * Thermally induced phase separation (TIPS) * Solvent induced phase separation (SIPS) * Encapsulation (NCAP) * RESPONSE VOLTAGE * Dielectric and resistive effects * Radial configuration * Bipolar configuration * Other director configurations * RESPONSE TIME * DISPLAY CONTRAST * Light scattering and index matching * Incorporation of dyes * Contrast measurements * PDLC DISPLAY DEVICES AND INNOVATIONS * Reflective direct view displays * Large-scale, flexible displays * Switchable windows * Projection displays * High definition spatial light modulator * Haze-free PDLC shutters: wide angle view displays * ENVIRONMENTAL STABILITY * ACKNOWLEDGEMENTS * REFERENCES

  5. Information rich display design

    International Nuclear Information System (INIS)

    Welch, Robin; Braseth, Alf Ove; Veland, Oeystein

    2004-01-01

    This paper presents the concept Information Rich Displays. The purpose of Information Rich Displays (IRDs) is to condensate prevailing information in process displays in such a way that each display format (picture) contains more relevant information for the user. Compared to traditional process control displays, this new concept allows the operator to attain key information at a glance and at the same time allows for improved monitoring of larger portions of the process. This again allows for reduced navigation between both process and trend displays and ease the cognitive demand on the operator. This concept has been created while working on designing display prototypes for the offshore petroleum production facilities of tomorrow. Offshore installations basically consist of wells, separation trains (where oil, gas and water are separated from each other), an oil tax measurement system (where oil quality is measured and the pressure increased to allow for export), gas compression (compression of gas for export) and utility systems (water treatment, chemical systems etc.). This means that an offshore control room operator has to deal with a complex process that comprises several functionally different systems. The need for a new approach to offshore display format design is in particular based on shortcomings in today's designs related to the keyhole effect, where the display format only reveals a fraction of the whole process. Furthermore, the upcoming introduction of larger off- and on-shore operation centres will increase the size and complexity of the operators' work domain. In the light of the increased demands on the operator, the proposed IRDs aim to counter the negative effects this may have on the workload. In this work we have attempted to classify the wide range of different roles an operator can have in different situations. The information content and amount being presented to the operator in a display should be viewed in context of the roles the

  6. Use of a Data-Linked Weather Information Display and Effects on Pilot Navigation Decision Making in a Piloted Simulation Study

    Science.gov (United States)

    Yuchnovicz, Daniel E.; Novacek, Paul F.; Burgess, Malcolm A.; Heck, Michael L.; Stokes, Alan F.

    2001-01-01

    This study provides recommendations to the FAA and to prospective manufacturers based on an exploration of the effects of data link weather displays upon pilot decision performance. An experiment was conducted with twenty-four current instrument rated pilots who were divided into two equal groups and presented with a challenging but realistic flight scenario involving weather containing significant embedded convective activity. All flights were flown in a full-mission simulation facility within instrument meteorological conditions. The inflight weather display depicted NexRad images, graphical METARs and textual METARs. The objective was to investigate the potential for misuse of a weather display, and incorporate recommendations for the design and use of these displays. The primary conclusion of the study found that the inflight weather display did not improve weather avoidance decision making. Some of the reasons to support this finding include: the pilot's inability to easily perceive their proximity to the storms, increased workload and difficulty in deciphering METAR textual data. The compelling nature of a graphical weather display caused many pilots to reduce their reliance on corroborating weather information from other sources. Minor changes to the weather display could improve the ability of a pilot to make better decisions on hazard avoidance.

  7. Market trends in the projection display industry

    Science.gov (United States)

    Dash, Sweta

    2000-04-01

    The projection display industry represents a multibillion- dollar market that includes four distinct technologies. High-volume consumer products and high-value business products drive the market, with different technologies being used in different application markets. The consumer market is dominated by rear CRT technology, especially in the projection television segment. But rear LCD (liquid crystal display) and rear reflective (DLP, or Digital Light ProcessingTM) televisions are slowly emerging as future competitors to rear CRT projectors. Front CRT projectors are still popular in the high-end home theater market. Front LCD technology and front DLP technology dominate the business market. Traditional light valve technology was the only solution for applications requiring high light outputs, but new three-chip DLP projectors meet the higher light output requirements at a lower price. In the last few years the strongest growth has been in the business market for multimedia presentation applications. This growth was due to the continued increase in display pixel formats, the continued reduction in projector weight, and the improved price/performance ratio. The projection display market will grow at a significant rate during the next five years, driven by the growth in ultraportable (market to digital and HDTV products.

  8. 77 FR 50593 - Safety Zone; Seafood Festival Fireworks Display, Marquette, MI

    Science.gov (United States)

    2012-08-22

    ...-AA00 Safety Zone; Seafood Festival Fireworks Display, Marquette, MI AGENCY: Coast Guard, DHS. ACTION... the Annual Marquette Seafood Festival. The Captain of the Port, Sector Sault Sainte Marie, has determined that the Marquette Seafood Festival Fireworks Display will pose significant risks to the public...

  9. Painting Reproductions on Display

    Directory of Open Access Journals (Sweden)

    Joanna Iranowska

    2017-09-01

    Full Text Available Paintings in museums might occasionally be replaced by a photoprint mimicking the original. This article is an investigation of what constitutes a good reproduction of an artwork (oil painting that is meant to be displayed. The article discusses what the usefulness of reproductions depends on, applying the Valuation Studies approach, which means the primary concern is with the practice of valuing itself. In other words, the study focuses on how museum experts evaluate reproduc-tions of oil paintings. The article analyses three cases of displaying digitally prin-ted copies of Edvard Munch's oil paintings between 2013 and 2015 in the Munch Museum and in the National Gallery in Oslo. The study is based on a series of semi-structured interviews with the experts, working at and for the museums, that were involved in producing and exhibiting of the photoprints: curators, con-servators, museum educators, and external manufacturers. The interviews were grouped into five clusters, which I have chosen to call registers of valuing following Frank Heuts and Annemarie Mol (2013. The described valuation practices have to do with delivering experiences to the public, obtaining mimetic resemblance, solving ethical aspects, exhibitions' budget, and last but not least, with the time perspective.

  10. Advances in infrastructure support for flat panel display manufacturing

    Science.gov (United States)

    Bardsley, James N.; Ciesinski, Michael F.; Pinnel, M. Robert

    1997-07-01

    The success of the US display industry, both in providing high-performance displays for the US Department of Defense at reasonable cost and in capturing a significant share of the global civilian market, depends on maintaining technological leadership and on building efficient manufacturing capabilities. The US Display Consortium (USDC) was set up in 1993 by the US Government and private industry to guide the development of the infrastructure needed to support the manufacturing of flat panel displays. This mainly involves the supply of equipment and materials, but also includes the formation of partnerships and the training of a skilled labor force. Examples are given of successful development projects, some involving USDC participation, others through independent efforts of its member companies. These examples show that US-based companies can achieve leadership positions in this young and rapidly growing global market.

  11. Extending a scatterplot for displaying group structure in multivariate ...

    African Journals Online (AJOL)

    ... when regarded as extensions of ordinary scatterplots to describe variation and group structure in multivariate observations, is demonstrated by presenting a case study from the South African wood pulp industry. It is shown how multidimensional standards specified by users of a product may be added to the biplot in the ...

  12. An Evaluation of Detect and Avoid (DAA) Displays for Unmanned Aircraft Systems: The Effect of Information Level and Display Location on Pilot Performance

    Science.gov (United States)

    Fern, Lisa; Rorie, R. Conrad; Pack, Jessica S.; Shively, R. Jay; Draper, Mark H.

    2015-01-01

    A consortium of government, industry and academia is currently working to establish minimum operational performance standards for Detect and Avoid (DAA) and Control and Communications (C2) systems in order to enable broader integration of Unmanned Aircraft Systems (UAS) into the National Airspace System (NAS). One subset of these performance standards will need to address the DAA display requirements that support an acceptable level of pilot performance. From a pilot's perspective, the DAA task is the maintenance of self separation and collision avoidance from other aircraft, utilizing the available information and controls within the Ground Control Station (GCS), including the DAA display. The pilot-in-the-loop DAA task requires the pilot to carry out three major functions: 1) detect a potential threat, 2) determine an appropriate resolution maneuver, and 3) execute that resolution maneuver via the GCS control and navigation interface(s). The purpose of the present study was to examine two main questions with respect to DAA display considerations that could impact pilots' ability to maintain well clear from other aircraft. First, what is the effect of a minimum (or basic) information display compared to an advanced information display on pilot performance? Second, what is the effect of display location on UAS pilot performance? Two levels of information level (basic, advanced) were compared across two levels of display location (standalone, integrated), for a total of four displays. The authors propose an eight-stage pilot-DAA interaction timeline from which several pilot response time metrics can be extracted. These metrics were compared across the four display conditions. The results indicate that the advanced displays had faster overall response times compared to the basic displays, however, there were no significant differences between the standalone and integrated displays. Implications of the findings on understanding pilot performance on the DAA task, the

  13. Display of nuclear medicine imaging studies

    International Nuclear Information System (INIS)

    Singh, B.; Kataria, S.K.; Samuel, A.M.

    2002-08-01

    Nuclear medicine imaging studies involve evaluation of a large amount of image data. Digital signal processing techniques have introduced processing algorithms that increase the information content of the display. Nuclear medicine imaging studies require interactive selection of suitable form of display and pre-display processing. Static imaging study requires pre-display processing to detect focal defects. Point operations (histogram modification) along with zoom and capability to display more than one image in one screen is essential. This album mode of display is also applicable to dynamic, MUGA and SPECT data. Isometric display or 3-D graph of the image data is helpful in some cases e.g. point spread function, flood field data. Cine display is used on a sequence of images e.g. dynamic, MUGA and SPECT imaging studies -to assess the spatial movement of tracer with time. Following methods are used at the investigator's discretion for inspection of the 3-D object. 1) Display of orthogonal projections, 2) Display of album of user selected coronal/ sagital/ transverse orthogonal slices, 3) Display of three orthogonal slices through user selected point, 4) Display of a set of orthogonal slices generated in the user-selected volume, 5) Generation and display of 3-D shaded surface. 6) Generation of volume data and display along with the 3-D shaded surface, 7) Side by side display orthogonal slices of two 3-D objects. Displaying a set of two-dimensional slices of a 3-D reconstructed object through shows all the defects but lacks the 3-D perspective. Display of shaded surface lacks the ability to show the embedded defects. Volume display -combining the 3-D surface and gray level volume data is perhaps the best form of display. This report describes these forms of display along with the theory. (author)

  14. Display technologies for augmented reality

    Science.gov (United States)

    Lee, Byoungho; Lee, Seungjae; Jang, Changwon; Hong, Jong-Young; Li, Gang

    2018-02-01

    With the virtue of rapid progress in optics, sensors, and computer science, we are witnessing that commercial products or prototypes for augmented reality (AR) are penetrating into the consumer markets. AR is spotlighted as expected to provide much more immersive and realistic experience than ordinary displays. However, there are several barriers to be overcome for successful commercialization of AR. Here, we explore challenging and important topics for AR such as image combiners, enhancement of display performance, and focus cue reproduction. Image combiners are essential to integrate virtual images with real-world. Display performance (e.g. field of view and resolution) is important for more immersive experience and focus cue reproduction may mitigate visual fatigue caused by vergence-accommodation conflict. We also demonstrate emerging technologies to overcome these issues: index-matched anisotropic crystal lens (IMACL), retinal projection displays, and 3D display with focus cues. For image combiners, a novel optical element called IMACL provides relatively wide field of view. Retinal projection displays may enhance field of view and resolution of AR displays. Focus cues could be reconstructed via multi-layer displays and holographic displays. Experimental results of our prototypes are explained.

  15. SoftCopy Display Quality Assurance Program at Texas Children's Hospital.

    Science.gov (United States)

    Ly, Catherine Kim

    2002-01-01

    With growing dependence on picture archiving and communication systems for viewing images, a quality assurance program to monitor the condition of workstation displays has become increasingly important. At present there is no universally accepted program for PACS, but there are groups such as DICOM Working Group 11 of the ACR-NEMA and AAPM Task Group 18 that are working on image quality guidelines for interpretation from soft-copy displays. Texas Children's Hospital (TCH) is developing our own quality assurance program. Data is being collected to determine the appropriate frequency of calibration, the useful life of the displays, appropriate manufacturers, and model-dependent limits on maximum and minimum luminance (black level), symptoms of degradation, and monitor cleanliness. Our system includes a variety of monitors manufactured by Sun, AFP, Siemens, Image Systems, Barco, and Orwin. We are presently collecting data on individual monitor luminance functions but have not yet initiated service calls based on deviation from the DICOM Part 14 Grayscale Display Function (GSDF). The GSDF was intended to produce a grayscale in which driving levels produce changes in luminance that are perceptually equivalent throughout the entire luminance range for a specific test target. Our data is based on measurements of luminance from a digital Society of Motion Picture and Television Engineers (SMPTE) test pattern, which is a standard used by many other institutions. TCH's biomedical engineer measures luminance data each month from the display of the SMPTE pattern and record the results in a spreadsheet. The engineer also makes subjective evaluations of sharpness, geometric distortion, and artifacts. When a monitor's luminance falls outside of arbitrary 10% limits of maximum or minimum luminance, then a service call is placed to the vendor. The luminance check by the biomedical engineer is used to verify both routine and unscheduled calibrations. In addition to the monthly

  16. Next generation smart window display using transparent organic display and light blocking screen.

    Science.gov (United States)

    Kim, Gyeong Woo; Lampande, Raju; Choe, Dong Cheol; Ko, Ik Jang; Park, Jin Hwan; Pode, Ramchandra; Kwon, Jang Hyuk

    2018-04-02

    Transparent organic light emitting diodes (TOLED) have widespread applications in the next-generation display devices particularly in the large size transparent window and interactive displays. Herein, we report high performance and stable attractive smart window displays using facile process. Advanced smart window display is realized by integrating the high performance light blocking screen and highly transparent white OLED panel. The full smart window display reveals a maximum transmittance as high as 64.2% at the wavelength of 600 nm and extremely good along with tunable ambient contrast ratio (171.94:1) compared to that of normal TOLED (4.54:1). Furthermore, the performance decisive light blocking screen has demonstrated an excellent optical and electrical characteristics such as i) high transmittance (85.56% at 562nm) at light-penetrating state, ii) superior absorbance (2.30 at 562nm) in light interrupting mode, iii) high optical contrast (85.50 at 562 nm), iv) high optical stability for more than 25,000 cycle of driving, v) fast switching time of 1.9 sec, and vi) low driving voltage of 1.7 V. The experimental results of smart window display are also validated using optical simulation. The proposed smart window display technology allows us to adjust the intensity of daylight entering the system quickly and conveniently.

  17. High performance visual display for HENP detectors

    International Nuclear Information System (INIS)

    McGuigan, Michael; Smith, Gordon; Spiletic, John; Fine, Valeri; Nevski, Pavel

    2001-01-01

    A high end visual display for High Energy Nuclear Physics (HENP) detectors is necessary because of the sheer size and complexity of the detector. For BNL this display will be of special interest because of STAR and ATLAS. To load, rotate, query, and debug simulation code with a modern detector simply takes too long even on a powerful work station. To visualize the HENP detectors with maximal performance we have developed software with the following characteristics. We develop a visual display of HENP detectors on BNL multiprocessor visualization server at multiple level of detail. We work with general and generic detector framework consistent with ROOT, GAUDI etc, to avoid conflicting with the many graphic development groups associated with specific detectors like STAR and ATLAS. We develop advanced OpenGL features such as transparency and polarized stereoscopy. We enable collaborative viewing of detector and events by directly running the analysis in BNL stereoscopic theatre. We construct enhanced interactive control, including the ability to slice, search and mark areas of the detector. We incorporate the ability to make a high quality still image of a view of the detector and the ability to generate animations and a fly through of the detector and output these to MPEG or VRML models. We develop data compression hardware and software so that remote interactive visualization will be possible among dispersed collaborators. We obtain real time visual display for events accumulated during simulations

  18. A projection graphic display for the computer aided analysis of bubble chamber images

    International Nuclear Information System (INIS)

    Solomos, E.

    1979-01-01

    A projection graphic display for aiding the analysis of bubble chamber photographs has been developed by the Instrumentation Group of EF Division at CERN. The display image is generated on a very high brightness cathode ray tube and projected on to the table of the scanning-measuring machines as a superposition to the image of the bubble chamber. The display can send messages to the operator and aid the measurement by indicating directly on the chamber image the tracks which are measured correctly or not. (orig.)

  19. Resolution and noise measurements of five CRT and LCD medical displays

    International Nuclear Information System (INIS)

    Saunders, Robert S. Jr.; Samei, Ehsan

    2006-01-01

    The performance of soft-copy displays plays a significant role in the overall image quality of a digital radiographic system. In this work, we discuss methods to characterize the resolution and noise of both cathode ray tube (CRT) and liquid crystal display (LCD) devices. We measured the image quality of five different commercial display devices, representing both CRT and LCD technologies, using a high-quality charge-coupled device (CCD) camera. The modulation transfer function (MTF) was calculated using the line technique, correcting for the MTF of the CCD camera and the display pixel size. The normalized noise power spectrum (NPS) was computed from two-dimensional Fourier analysis of uniform images. To separate the effects of pixel structure from interpixel luminance variations, we created structure-free images by eliminating the pixel structures of the display device. The NPS was then computed from these structure-free images to isolate interpixel luminance variations. We found that the MTF of LCDs remained close to the theoretical limit dictated by their inherent pixel size (0.85±0.08 at Nyquist frequency), in contrast to the MTF for the two CRT displays, which dropped to 0.15±0.08 at the Nyquist frequency. However, the NPS of LCDs showed significant peaks due to the subpixel structure, while the NPS of CRT displays exhibited a nearly flat power spectrum. After removing the pixel structure, the structured noise peaks for LCDs were eliminated and the overall noise magnitude was significantly reduced. The average total noise-to-signal ratio for CRT displays was 6.55%±0.59%, of which 6.03%±0.24% was due to interpixel luminance variations, while LCD displays had total noise to signal ratios of 46.1%±5.1% of which 1.50%±0.41% were due to interpixel luminance variations. Depending on the extent of the blurring and prewhitening processes of the human visual system, the magnitude of the display noise (including pixel structure) potentially perceived by the

  20. Visual merchandising window display

    Directory of Open Access Journals (Sweden)

    Opris (Cas. Stanila M.

    2013-12-01

    Full Text Available Window display plays a major part in the selling strategies; it does not only include the simple display of goods, nowadays it is a form of art, also having the purpose of sustaining the brand image. This article wants to reveal the tools that are essential in creating a fabulous window display. Being a window designer is not an easy job, you have to always think ahead trends, to have a sense of colour, to know how to use light to attract customers in the store after only one glance at the window. The big store window displays are theatre scenes: with expensive backgrounds, special effects and high fashion mannequins. The final role of the displays is to convince customers to enter the store and trigger the purchasing act which is the final goal of the retail activity.

  1. Extending a scatterplot for displaying group structure in multivariate ...

    African Journals Online (AJOL)

    is awarded a credibility rating of A, B, C or D according to various financial ... of finding groups in data (see for example Kaufman and Rousseeuw (1990), McLachlan ..... Kraft liner. Sack paper. Min. Max. Min. Max. Total Yield. 43. 50. 43. 50. Alkali. 70 ..... ley J, Gourlay ID, O'Brien E, Plumptre RA & Quilter AK, 2003, Effect of.

  2. High Resolution Displays Using NCAP Liquid Crystals

    Science.gov (United States)

    Macknick, A. Brian; Jones, Phil; White, Larry

    1989-07-01

    Nematic curvilinear aligned phase (NCAP) liquid crystals have been found useful for high information content video displays. NCAP materials are liquid crystals which have been encapsulated in a polymer matrix and which have a light transmission which is variable with applied electric fields. Because NCAP materials do not require polarizers, their on-state transmission is substantially better than twisted nematic cells. All dimensional tolerances are locked in during the encapsulation process and hence there are no critical sealing or spacing issues. By controlling the polymer/liquid crystal morphology, switching speeds of NCAP materials have been significantly improved over twisted nematic systems. Recent work has combined active matrix addressing with NCAP materials. Active matrices, such as thin film transistors, have given displays of high resolution. The paper will discuss the advantages of NCAP materials specifically designed for operation at video rates on transistor arrays; applications for both backlit and projection displays will be discussed.

  3. Performance analysis of multi-primary color display based on OLEDs/PLEDs

    Science.gov (United States)

    Xiong, Yan; Deng, Fei; Xu, Shan; Gao, Shufang

    2017-09-01

    A multi-primary color display, such as the six-primary color format, is a solution in expanding the color gamut of a full-color flat panel display. The performance of a multi-primary color display based on organic/polymer light-emitting diodes was analyzed in this study using the fitting curves of the characteristics of devices (i.e., current density, voltage, luminance). A white emitter was introduced into a six-primary color format to form a seven-primary color format that contributes to energy saving, and the ratio of power efficiency of a seven-primary color display to that of a six-primary color display would increase from 1.027 to 1.061 by using emitting diodes with different electroluminescent efficiencies. Different color matching schemes of the seven-primary color format display were compared in a uniform color space, and the scheme of the color reproduction did not significantly affect the display performance. Although seven- and six-primary color format displays benefit a full-color display with higher quality, they are less efficient than three-primary (i.e., red (R), green (G), and blue (B), RGB) and four-primary (i.e., RGB+white, RGBW) color format displays. For the seven-primary color formats considered in this study, the advantages of white-primary-added display with efficiently developed light-emitting devices were more evident than the format without a white primary.

  4. Nuclear Medicine Image Display. Chapter 14

    Energy Technology Data Exchange (ETDEWEB)

    Bergmann, H. [Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna (Austria)

    2014-12-15

    The final step in a medical imaging procedure is to display the image(s) on a suitable display system where it is presented to the medical specialist for diagnostic interpretation. The display of hard copy images on X ray film or photographic film has largely been replaced today by soft copy image display systems with cathode ray tube (CRT) or liquid crystal display (LCD) monitors as the image rendering device. Soft copy display requires a high quality display monitor and a certain amount of image processing to optimize the image both with respect to the properties of the display device and to some psychophysiological properties of the human visual system. A soft copy display system, therefore, consists of a display workstation providing some basic image processing functions and the display monitor as the intrinsic display device. Display devices of lower quality may be used during intermediate steps of the acquisition and analysis of a patient study. Display monitors with a quality suitable for diagnostic reading by the specialist medical doctor are called primary devices, also known as diagnostic devices. Monitors with lower quality but good enough to be used for positioning, processing of studies, presentation of images in the wards, etc. are referred to as secondary devices or clinical devices. Nuclear medicine images can be adequately displayed even for diagnostic purposes on secondary devices. However, the increasing use of X ray images on which to report jointly with images from nuclear medicine studies, such as those generated by dual modality imaging, notably by positron emission tomography (PET)/computed tomography (CT) and single photon emission computed tomography (SPECT)/CT, requires display devices capable of visualizing high resolution grey scale images at diagnostic quality, i.e. primary display devices. Both grey scale and colour display devices are used, the latter playing an important role in the display of processed nuclear medicine images and

  5. Nuclear Medicine Image Display. Chapter 14

    International Nuclear Information System (INIS)

    Bergmann, H.

    2014-01-01

    The final step in a medical imaging procedure is to display the image(s) on a suitable display system where it is presented to the medical specialist for diagnostic interpretation. The display of hard copy images on X ray film or photographic film has largely been replaced today by soft copy image display systems with cathode ray tube (CRT) or liquid crystal display (LCD) monitors as the image rendering device. Soft copy display requires a high quality display monitor and a certain amount of image processing to optimize the image both with respect to the properties of the display device and to some psychophysiological properties of the human visual system. A soft copy display system, therefore, consists of a display workstation providing some basic image processing functions and the display monitor as the intrinsic display device. Display devices of lower quality may be used during intermediate steps of the acquisition and analysis of a patient study. Display monitors with a quality suitable for diagnostic reading by the specialist medical doctor are called primary devices, also known as diagnostic devices. Monitors with lower quality but good enough to be used for positioning, processing of studies, presentation of images in the wards, etc. are referred to as secondary devices or clinical devices. Nuclear medicine images can be adequately displayed even for diagnostic purposes on secondary devices. However, the increasing use of X ray images on which to report jointly with images from nuclear medicine studies, such as those generated by dual modality imaging, notably by positron emission tomography (PET)/computed tomography (CT) and single photon emission computed tomography (SPECT)/CT, requires display devices capable of visualizing high resolution grey scale images at diagnostic quality, i.e. primary display devices. Both grey scale and colour display devices are used, the latter playing an important role in the display of processed nuclear medicine images and

  6. Behavioral and Academic Progress of Children Displaying Substantive ADHD Behaviors in Special Education: A 1-Year Follow-up.

    Science.gov (United States)

    Stoutjesdijk, Regina; Scholte, Evert M; Swaab, Hanna

    2016-01-01

    Exploring differences in behavioral and academic progress between children displaying substantive ADHD behaviors (M age of 9.4 years) in special schools (n = 38) and in inclusive education (n = 26). The contribution of pedagogical strategies to positive outcomes was also examined. Measurements used were the Teachers' Report Form, the Social Emotional Questionnaire, assessments of academic achievement, and the Pedagogical Methods Questionnaire. Mixed-model ANOVAs and Pearson's correlations were used to analyze the data. Significant progress was found regarding disorder-specific problem behavior and in all academic areas, but no interaction effect was found between time and setting. Correlations indicated that positive behavior reinforcement and emotional support are the pedagogical strategies that contributed most to behavioral adaptation. Children displaying substantive ADHD behaviors in both groups develop equally well in the areas of behavioral and academic functioning where significant progress was found. © The Author(s) 2013.

  7. COREMAP - Graphical User Interface for displaying reactor core data in an interactive hexagonal map

    International Nuclear Information System (INIS)

    Muscat, F.L.; Derstine, K.L.

    1995-01-01

    COREMAP displays reactor core data from multidimensional neutronic simulation models in color and/or as text in an interactive 2D planar grid of hexagonal subassemblies. The interactive (point and click) interface enables the user to access multi data set files (e.g.. planes, moments, energy groups, ...) and to display up to two data sets simultaneously, one as text and the other as color. The user (1) controls color scale characteristics (linear or logarithmic) with a variety of range limits, (2) chooses zoom features (map size, ring number and surrounding subassemblies), (3) is supplied with popup sub-windows to display data from planes and energy groups currently offscreen for the selected cell. Three color scale shading techniques may be used to display data on any bitmapped screen monitor. Most effective displays are obtained with shades of blue and red on color monitors, shades of grey on greyscale monitors or stipple patterns on monochrome monitors. A fully automated printing option creates high quality PostScript color or greyscale images of the core map independent of the monitor used, e.g. color prints can be generated with a session from a monochrome monitor

  8. [Significance of expert-guided groups for relatives in psychiatry].

    Science.gov (United States)

    Plessen, U; Postzich, M; Wilkmann, M

    1985-03-01

    Psychiatric interest in relatives of patients was concentrated in the past on their pathogenetic and etiological influence on mental illness. The medical paradigma of mental illness did not account for relatives affliction in psychic disturbance of their family member. Against this a community care oriented approach involves relatives into psychiatric care, particularly under the aspects of coping strategies and rehabilitative sources. Practicability and effects of this approach were explored in expert-guided relative groups at the Psychiatric Hospital Gütersloh (FRG). Results indicated that relatives are concerned with a series of problems. Participating in relative groups facilitates coping with these problems. Expert-guided and relative centered groups were found helpful, discharging and encouraging for relatives.

  9. Display systems for NPP control

    International Nuclear Information System (INIS)

    Rozov, S.S.

    1988-01-01

    Main trends in development of display systems used as the means for image displaying in NPP control systems are considered. It is shown that colour display devices appear to be the most universal means for concentrated data presentation. Along with digital means the display systems provide for high-speed response, sufficient for operative control of executive mechanisms. A conclusion is drawn that further development of display systems will move towards creation of large colour fields (on reflection base or with multicolour gas-discharge elements)

  10. Treating panic symptoms within everyday clinical settings: the feasibility of a group cognitive behavioural intervention

    DEFF Research Database (Denmark)

    Austin, S.F.; Sumbundu, A.D.; Lykke, J.

    2008-01-01

    of significant clinical change displayed and resources required to carry out the intervention. A small sample of GP-referred patients displaying panic symptoms completed a 2-week intensive cognitive-behavioural intervention. Results collected post-intervention revealed significant clinical reductions in panic......Panic disorder is a common and debilitating disorder that has a prevalence rate of 3-5% in the general population. Cognitive-behavioural interventions have been shown to be an efficacious treatment for panic, although a limited number of studies have examined the effectiveness of such interventions...... implemented in everyday clinical settings. The aim of the following pilot study was to examine the feasibility of a brief group cognitive-behavioural intervention carried out in a clinical setting. Salient issues in determining feasibility include: representativeness of patient group treated, amount...

  11. Ribosome display: next-generation display technologies for production of antibodies in vitro.

    Science.gov (United States)

    He, Mingyue; Khan, Farid

    2005-06-01

    Antibodies represent an important and growing class of biologic research reagents and biopharmaceutical products. They can be used as therapeutics in a variety of diseases. With the rapid expansion of proteomic studies and biomarker discovery, there is a need for the generation of highly specific binding reagents to study the vast number of proteins encoded by the genome. Display technologies provide powerful tools for obtaining antibodies. Aside from the preservation of natural antibody repertoires, they are capable of exploiting diversity by DNA recombination to create very large libraries for selection of novel molecules. In contrast to in vivo immunization processes, display technologies allow selection of antibodies under in vitro-defined selection condition(s), resulting in enrichment of antibodies with desired properties from large populations. In addition, in vitro selection enables the isolation of antibodies against difficult antigens including self-antigens, and this can be applied to the generation of human antibodies against human targets. Display technologies can also be combined with DNA mutagenesis for antibody evolution in vitro. Some methods are amenable to automation, permitting high-throughput generation of antibodies. Ribosome display is considered as representative of the next generation of display technologies since it overcomes the limitations of cell-based display methods by using a cell-free system, offering advantages of screening larger libraries and continuously expanding new diversity during selection. Production of display-derived antibodies can be achieved by choosing one of a variety of prokaryotic and eukaryotic cell-based expression systems. In the near future, cell-free protein synthesis may be developed as an alternative for large-scale generation of antibodies.

  12. Large-screen display industry: market and technology trends for direct view and projection displays

    Science.gov (United States)

    Castellano, Joseph A.; Mentley, David E.

    1996-03-01

    Large screen information displays are defined as dynamic electronic displays that can be viewed by more than one person and are at least 2-feet wide. These large area displays for public viewing provide convenience, entertainment, security, and efficiency to the viewers. There are numerous uses for large screen information displays including those in advertising, transportation, traffic control, conference room presentations, computer aided design, banking, and military command/control. A noticeable characteristic of the large screen display market is the interchangeability of display types. For any given application, the user can usually choose from at least three alternative technologies, and sometimes from many more. Some display types have features that make them suitable for specific applications due to temperature, brightness, power consumption, or other such characteristic. The overall worldwide unit consumption of large screen information displays of all types and for all applications (excluding consumer TV) will increase from 401,109 units in 1995 to 655,797 units in 2002. On a unit consumption basis, applications in business and education represent the largest share of unit consumption over this time period; in 1995, this application represented 69.7% of the total. The market (value of shipments) will grow from DOL3.1 billion in 1995 to DOL3.9 billion in 2002. The market will be dominated by front LCD projectors and LCD overhead projector plates.

  13. Spacesuit Data Display and Management System

    Science.gov (United States)

    Hall, David G.; Sells, Aaron; Shah, Hemal

    2009-01-01

    A prototype embedded avionics system has been designed for the next generation of NASA extra-vehicular-activity (EVA) spacesuits. The system performs biomedical and other sensor monitoring, image capture, data display, and data transmission. An existing NASA Phase I and II award winning design for an embedded computing system (ZIN vMetrics - BioWATCH) has been modified. The unit has a reliable, compact form factor with flexible packaging options. These innovations are significant, because current state-of-the-art EVA spacesuits do not provide capability for data displays or embedded data acquisition and management. The Phase 1 effort achieved Technology Readiness Level 4 (high fidelity breadboard demonstration). The breadboard uses a commercial-grade field-programmable gate array (FPGA) with embedded processor core that can be upgraded to a space-rated device for future revisions.

  14. Epitope selection from an uncensored peptide library displayed on avian leukosis virus

    International Nuclear Information System (INIS)

    Khare, Pranay D.; Rosales, Ana G.; Bailey, Kent R.; Russell, Stephen J.; Federspiel, Mark J.

    2003-01-01

    Phage display libraries have provided an extraordinarily versatile technology to facilitate the isolation of peptides, growth factors, single chain antibodies, and enzymes with desired binding specificities or enzymatic activities. The overall diversity of peptides in phage display libraries can be significantly limited by Escherichia coli protein folding and processing machinery, which result in sequence censorship. To achieve an optimal diversity of displayed eukaryotic peptides, the library should be produced in the endoplasmic reticulum of eukaryotic cells using a eukaryotic display platform. In the accompanying article, we presented experiments that demonstrate that polypeptides of various sizes could be efficiently displayed on the envelope glycoproteins of a eukaryotic virus, avian leukosis virus (ALV), and the displayed polypeptides could efficiently attach to cognate receptors without interfering with viral attachment and entry into susceptible cells. In this study, methods were developed to construct a model library of randomized eight amino acid peptides using the ALV eukaryotic display platform and screen the library for specific epitopes using immobilized antibodies. A virus library with approximately 2 x 10 6 different members was generated from a plasmid library of approximately 5 x 10 6 diversity. The sequences of the randomized 24 nucleotide/eight amino acid regions of representatives of the plasmid and virus libraries were analyzed. No significant sequence censorship was observed in producing the virus display library from the plasmid library. Different populations of peptide epitopes were selected from the virus library when different monoclonal antibodies were used as the target. The results of these two studies clearly demonstrate the potential of ALV as a eukaryotic platform for the display and selection of eukaryotic polypeptides libraries

  15. Evaluation of an integrated graphical display to promote acute change detection in ICU patients

    Science.gov (United States)

    Anders, Shilo; Albert, Robert; Miller, Anne; Weinger, Matthew B.; Doig, Alexa K.; Behrens, Michael; Agutter, Jim

    2012-01-01

    Objective The purpose of this study was to evaluate ICU nurses’ ability to detect patient change using an integrated graphical information display (IGID) versus a conventional tabular ICU patient information display (i.e. electronic chart). Design Using participants from two different sites, we conducted a repeated measures simulator-based experiment to assess ICU nurses’ ability to detect abnormal patient variables using a novel IGID versus a conventional tabular information display. Patient scenarios and display presentations were fully counterbalanced. Measurements We measured percent correct detection of abnormal patient variables, nurses’ perceived workload (NASA-TLX), and display usability ratings. Results 32 ICU nurses (87% female, median age of 29 years, and median ICU experience of 2.5 years) using the IGID detected more abnormal variables compared to the tabular display [F (1,119)=13.0, p < 0.05]. There was a significant main effect of site [F (1, 119)=14.2], with development site participants doing better. There were no significant differences in nurses’ perceived workload. The IGID display was rated as more usable than the conventional display, [F (1, 60)=31.7]. Conclusion Overall, nurses reported more important physiological information with the novel IGID than tabular display. Moreover, the finding of site differences may reflect local influences in work practice and involvement in iterative display design methodology. Information displays developed using user-centered design should accommodate the full diversity of the intended user population across use sites. PMID:22534099

  16. The effect of time in use on the display performance of the iPad.

    Science.gov (United States)

    Caffery, Liam J; Manthey, Kenneth L; Sim, Lawrence H

    2016-07-01

    The aim of this study was to evaluate changes to the luminance, luminance uniformity and conformance to the digital imaging and communication in medicine greyscale standard display function (GSDF) as a function of time in use for the iPad. Luminance measurements of the American Association of Physicists in Medicine (AAPM) Group 18 task group (TG18) luminance uniformity and luminance test patterns (TG18-UNL and TG18-LN8) were performed using a calibrated near-range luminance meter. Nine sets of measurements were taken, where the time in use of the iPad ranged from 0 to 2500 h. The maximum luminance (Lmax) of the display decreased (367-338 cdm(-2)) as a function of time. The minimum luminance remained constant. The maximum non-uniformity coefficient was 11%. Luminance uniformity decreased slightly as a function of time in use. The conformance of the iPad deviated from the GSDF curve at commencement of use. Deviation did not increase as a function of time in use. This study has demonstrated that the iPad display exhibits luminance degradation typical of liquid crystal displays. The Lmax of the iPad fell below the American College of Radiology-AAPM-Society of Imaging Informatics in Medicine recommendations for primary displays (>350 cdm(-2)) at approximately 1000 h in use. The Lmax recommendation for secondary displays (>250 cdm(-2)) was exceeded during the entire study. The maximum non-uniformity coefficient did not exceed the recommendations for either primary or secondary displays. The deviation from the GSDF exceeded the recommendations of the TG18 for use as either a primary or secondary display. The brightness, uniformity and contrast response are reasonably stable over the useful lifetime of the device; however, the device fails to meet the contrast response standard for either a primary or secondary display.

  17. Controlling Power Consumption for Displays With Backlight Dimming

    DEFF Research Database (Denmark)

    Mantel, Claire; Burini, Nino; Nadernejad, Ehsan

    2013-01-01

    Backlight dimming of Liquid Crystal Displays (LCD) is a technology which aims at saving power and improving visual quality. The evolution of energy standards and the increasing public expectations regarding power consumption have made it necessary for backlight systems to manage their power....... Such a control is challenging to implement, because for LCD displays quality and power are closely interlinked, and one cannot be modified without affecting the other. To address this issue, we present a framework for power controlled backlight dimming defining some key concepts. Two methods to obtain backlights...... with a predefined power level for images are presented: one method has low complexity and the other achieves high performance in terms of quality/power trade-off. Those methods are evaluated on a modeled Light-Emitting Diode edge-lit backlight display. The high-performance method performs significantly better than...

  18. An interactive display system for large-scale 3D models

    Science.gov (United States)

    Liu, Zijian; Sun, Kun; Tao, Wenbing; Liu, Liman

    2018-04-01

    With the improvement of 3D reconstruction theory and the rapid development of computer hardware technology, the reconstructed 3D models are enlarging in scale and increasing in complexity. Models with tens of thousands of 3D points or triangular meshes are common in practical applications. Due to storage and computing power limitation, it is difficult to achieve real-time display and interaction with large scale 3D models for some common 3D display software, such as MeshLab. In this paper, we propose a display system for large-scale 3D scene models. We construct the LOD (Levels of Detail) model of the reconstructed 3D scene in advance, and then use an out-of-core view-dependent multi-resolution rendering scheme to realize the real-time display of the large-scale 3D model. With the proposed method, our display system is able to render in real time while roaming in the reconstructed scene and 3D camera poses can also be displayed. Furthermore, the memory consumption can be significantly decreased via internal and external memory exchange mechanism, so that it is possible to display a large scale reconstructed scene with over millions of 3D points or triangular meshes in a regular PC with only 4GB RAM.

  19. Visual merchandising displays: the fashion retailer’s competitive edge?

    Directory of Open Access Journals (Sweden)

    Elsa C. Nell

    2015-10-01

    Full Text Available Visual merchandising has been called the silent salesman and retailers will be wise to use this silent salesman to enhance their total offering. This makes the in-store environment the perfect tool for fashion retailers to create a competitive advantage that other retailers might not have. The main research objective of this study was to explore if visual merchandising displays can be utilised to create a competitive advantage in fashion retail stores. A secondary objective was to explore the effect that visual merchandising displays have on a fashion retailer’s retail image. Qualitative research was performed by means of focus groups and the respondents were selected by means of purposive sampling. Thereafter, the data was analysed using thematic analysis. The results indicated that visual merchandising displays not only influence store image by communicating product quality and store character, but that they also create a purchasing environment that encourages impulse buying.

  20. Volumetric 3D Display System with Static Screen

    Science.gov (United States)

    Geng, Jason

    2011-01-01

    Current display technology has relied on flat, 2D screens that cannot truly convey the third dimension of visual information: depth. In contrast to conventional visualization that is primarily based on 2D flat screens, the volumetric 3D display possesses a true 3D display volume, and places physically each 3D voxel in displayed 3D images at the true 3D (x,y,z) spatial position. Each voxel, analogous to a pixel in a 2D image, emits light from that position to form a real 3D image in the eyes of the viewers. Such true volumetric 3D display technology provides both physiological (accommodation, convergence, binocular disparity, and motion parallax) and psychological (image size, linear perspective, shading, brightness, etc.) depth cues to human visual systems to help in the perception of 3D objects. In a volumetric 3D display, viewers can watch the displayed 3D images from a completely 360 view without using any special eyewear. The volumetric 3D display techniques may lead to a quantum leap in information display technology and can dramatically change the ways humans interact with computers, which can lead to significant improvements in the efficiency of learning and knowledge management processes. Within a block of glass, a large amount of tiny dots of voxels are created by using a recently available machining technique called laser subsurface engraving (LSE). The LSE is able to produce tiny physical crack points (as small as 0.05 mm in diameter) at any (x,y,z) location within the cube of transparent material. The crack dots, when illuminated by a light source, scatter the light around and form visible voxels within the 3D volume. The locations of these tiny voxels are strategically determined such that each can be illuminated by a light ray from a high-resolution digital mirror device (DMD) light engine. The distribution of these voxels occupies the full display volume within the static 3D glass screen. This design eliminates any moving screen seen in previous

  1. Scalable Resolution Display Walls

    KAUST Repository

    Leigh, Jason; Johnson, Andrew; Renambot, Luc; Peterka, Tom; Jeong, Byungil; Sandin, Daniel J.; Talandis, Jonas; Jagodic, Ratko; Nam, Sungwon; Hur, Hyejung; Sun, Yiwen

    2013-01-01

    This article will describe the progress since 2000 on research and development in 2-D and 3-D scalable resolution display walls that are built from tiling individual lower resolution flat panel displays. The article will describe approaches and trends in display hardware construction, middleware architecture, and user-interaction design. The article will also highlight examples of use cases and the benefits the technology has brought to their respective disciplines. © 1963-2012 IEEE.

  2. X-Windows Widget for Image Display

    Science.gov (United States)

    Deen, Robert G.

    2011-01-01

    XvicImage is a high-performance XWindows (Motif-compliant) user interface widget for displaying images. It handles all aspects of low-level image display. The fully Motif-compliant image display widget handles the following tasks: (1) Image display, including dithering as needed (2) Zoom (3) Pan (4) Stretch (contrast enhancement, via lookup table) (5) Display of single-band or color data (6) Display of non-byte data (ints, floats) (7) Pseudocolor display (8) Full overlay support (drawing graphics on image) (9) Mouse-based panning (10) Cursor handling, shaping, and planting (disconnecting cursor from mouse) (11) Support for all user interaction events (passed to application) (12) Background loading and display of images (doesn't freeze the GUI) (13) Tiling of images.

  3. Study on the visibility of an electroluminescent display for automobiles; Jidoshayo EL display no shininsei

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, N; Harada, M; Idogaki, T [Denso Corp., Aichi (Japan)

    1997-10-01

    This report explores the visibility of an Electroluminescent (EL) display for automotive use. Displays for automobiles are exposed to the direct rays of the sun and forced to operate in wide temperature range. Therefore, luminous flux density by the lighting on EL display panel and operating environment temperature must be considered for the visibility evaluation. Sensory evaluation on the visibility and physical measurements such as contrast, chromaticity difference in accordance with the viewing angle change indicate that the visibility of the EL display for automobiles is advantageous over other displays. 6 refs., 11 figs., 1 tab.

  4. Laser illuminated flat panel display

    Energy Technology Data Exchange (ETDEWEB)

    Veligdan, J.T.

    1995-12-31

    A 10 inch laser illuminated flat panel Planar Optic Display (POD) screen has been constructed and tested. This POD screen technology is an entirely new concept in display technology. Although the initial display is flat and made of glass, this technology lends itself to applications where a plastic display might be wrapped around the viewer. The display screen is comprised of hundreds of planar optical waveguides where each glass waveguide represents a vertical line of resolution. A black cladding layer, having a lower index of refraction, is placed between each waveguide layer. Since the cladding makes the screen surface black, the contrast is high. The prototype display is 9 inches wide by 5 inches high and approximately I inch thick. A 3 milliwatt HeNe laser is used as the illumination source and a vector scanning technique is employed.

  5. OLED displays and lighting

    CERN Document Server

    Koden, Mitsuhiro

    2017-01-01

    Organic light-emitting diodes (OLEDs) have emerged as the leading technology for the new display and lighting market. OLEDs are solid-state devices composed of thin films of organic molecules that create light with the application of electricity. OLEDs can provide brighter, crisper displays on electronic devices and use less power than conventional light-emitting diodes (LEDs) or liquid crystal displays (LCDs) used today. This book covers both the fundamentals and practical applications of flat and flexible OLEDs.

  6. Optical characterization of display screens by speckle patterns

    Science.gov (United States)

    Pozo, Antonio M.; Castro, José J.; Rubiño, Manuel

    2013-10-01

    In recent years, flat-panel display (FPD) technology has undergone great development, and now FPDs appear in many devices. A significant element in FPD manufacturing is the display front surface. Manufacturers sell FPDs with different types of front surfaces, which can be matte (also called anti-glare) or glossy screens. Users who prefer glossy screens consider these displays to show more vivid colors compared with matte-screen displays. However, on the glossy screens, external light sources may cause unpleasant reflections that can be reduced by a matte treatment in the front surface. In this work, we present a method to characterize FPD screens using laser-speckle patterns. We characterize three FPDs: a Samsung XL2370 LCD monitor of 23 in. with matte screen, a Toshiba Satellite A100 LCD laptop of 15.4 in. with glossy screen, and a Grammata Papyre 6.1 electronic book reader of 6 in. with ePaper screen (E-ink technology). The results show great differences in speckle-contrast values for the three screens characterized and, therefore, this work shows the feasibility of this method for characterizing and comparing FPDs that have different types of front surfaces.

  7. Design and Development of Functionally Effective Human-Machine Interfaces for Firing Room Displays

    Science.gov (United States)

    Cho, Henry

    2013-01-01

    This project involves creating software for support equipment used on the Space Launch System (SLS). The goal is to create applications and displays that will be used to remotely operate equipment from the firing room and will continue to support the SLS launch vehicle to the extent of its program. These displays include design practices that help to convey information effectively, such as minimizing distractions at normal operating state and displaying intentional distractions during a warning or alarm state. The general practice for creating an operator display is to reduce the detail of unimportant aspects of the display and promote focus on data and dynamic information. These practices include using minimalist design, using muted tones for background colors, using a standard font at a readable text size, displaying alarms visible for immediate attention, grouping data logically, and displaying data appropriately varying on the type of data. Users of these displays are more likely to stay focused on operating for longer periods by using design practices that reduce eye strain and fatigue. Effective operator displays will improve safety by reducing human errors during operation, which will help prevent catastrophic accidents. This report entails the details of my work on developing remote displays for the Hypergolic fuel servicing system. Before developing a prototype display, the design and requirements of the system are outlined and compiled into a document. Then each subsystem has schematic representations drawn that meet the specifications detailed in the document. The schematics are then used as the outline to create display representations of each subsystem. Each display is first tested individually. Then the displays are integrated with a prototype of the master system, and they are tested in a simulated environment then retested in the real environment. Extensive testing is important to ensure the displays function reliably as intended.

  8. ATLAS 13 TeV event displays - 2017 Summer Conferences

    CERN Multimedia

    ATLAS Collaboration

    2017-01-01

    Summer 2017: The ATLAS Collaboration released an impressive number of results using data collected at 13 TeV. Some of the corresponding event displays are grouped here for media and press. The reference to the conference note is given in the caption. Read more on ATLAS results with the links provided below.

  9. Eye Gaze Controlled Projected Display in Automotive and Military Aviation Environments

    Directory of Open Access Journals (Sweden)

    Gowdham Prabhakar

    2018-01-01

    Full Text Available This paper presents an eye gaze controlled projected display that can be used in aviation and automotive environment as a head up display. We have presented details of the hardware and software used in developing the display and an algorithm to improve performance of point and selection tasks in eye gaze controlled graphical user interface. The algorithm does not require changing layout of an interface; it rather puts a set of hotspots on clickable targets using a Simulated Annealing algorithm. Four user studies involving driving and flight simulators have found that the proposed projected display can improve driving and flying performance and significantly reduce pointing and selection times for secondary mission control tasks compared to existing interaction systems.

  10. Crosstalk evaluation in stereoscopic displays

    NARCIS (Netherlands)

    Wang, L.; Teunissen, C.; Tu, Yan; Chen, Li; Zhang, P.; Zhang, T.; Heynderickx, I.E.J.

    2011-01-01

    Substantial progress in liquid-crystal display and polarization film technology has enabled several types of stereoscopic displays. Despite all progress, some image distortions still exist in these 3-D displays, of which interocular crosstalk - light leakage of the image for one eye to the other eye

  11. A deviation display method for visualising data in mobile gamma-ray spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Kock, Peder, E-mail: Peder.Kock@med.lu.s [Department of Medical Radiation Physics, Clinical Sciences, Lund University, University Hospital, SE-221 85 Lund (Sweden); Finck, Robert R. [Swedish Radiation Protection Authority, SE-171 16 Stockholm (Sweden); Nilsson, Jonas M.C.; Ostlund, Karl; Samuelsson, Christer [Department of Medical Radiation Physics, Clinical Sciences, Lund University, University Hospital, SE-221 85 Lund (Sweden)

    2010-09-15

    A real time visualisation method, to be used in mobile gamma-spectrometric search operations using standard detector systems is presented. The new method, called deviation display, uses a modified waterfall display to present relative changes in spectral data over energy and time. Using unshielded {sup 137}Cs and {sup 241}Am point sources and different natural background environments, the behaviour of the deviation displays is demonstrated and analysed for two standard detector types (NaI(Tl) and HPGe). The deviation display enhances positive significant changes while suppressing the natural background fluctuations. After an initialisation time of about 10 min this technique leads to a homogeneous display dominated by the background colour, where even small changes in spectral data are easy to discover. As this paper shows, the deviation display method works well for all tested gamma energies and natural background radiation levels and with both tested detector systems.

  12. A deviation display method for visualising data in mobile gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Kock, Peder; Finck, Robert R.; Nilsson, Jonas M.C.; Ostlund, Karl; Samuelsson, Christer

    2010-01-01

    A real time visualisation method, to be used in mobile gamma-spectrometric search operations using standard detector systems is presented. The new method, called deviation display, uses a modified waterfall display to present relative changes in spectral data over energy and time. Using unshielded 137 Cs and 241 Am point sources and different natural background environments, the behaviour of the deviation displays is demonstrated and analysed for two standard detector types (NaI(Tl) and HPGe). The deviation display enhances positive significant changes while suppressing the natural background fluctuations. After an initialisation time of about 10 min this technique leads to a homogeneous display dominated by the background colour, where even small changes in spectral data are easy to discover. As this paper shows, the deviation display method works well for all tested gamma energies and natural background radiation levels and with both tested detector systems.

  13. High luminance monochrome vs. color displays: impact on performance and search

    Science.gov (United States)

    Krupinski, Elizabeth A.; Roehrig, Hans; Matsui, Takashi

    2011-03-01

    To determine if diagnostic accuracy and visual search efficiency with a high luminance medical-grade color display are equivalent to a high luminance medical-grade monochrome display. Six radiologists viewed DR chest images, half with a solitary pulmonary nodule and half without. Observers reported whether or not a nodule was present and their confidence in that decision. Total viewing time per image was recorded. On a subset of 15 cases eye-position was recorded. Confidence data were analyzed using MRMC ROC techniques. There was no statistically significant difference (F = 0.0136, p = 0.9078) between color (mean Az = 0.8981, se = 0.0065) and monochrome (mean Az = 0.8945, se = 0.0148) diagnostic performance. Total viewing time per image did not differ significantly (F = 0.392, p = 0.5315) as a function of color (mean = 27.36 sec, sd = 12.95) vs monochrome (mean = 28.04, sd = 14.36) display. There were no significant differences in decision dwell times (true and false, positive and negative) overall for color vs monochrome displays (F = 0.133, p = 0.7154). The true positive (TP) and false positive (FP) decisions were associated with the longest dwell times, the false negatives (FN) with slightly shorter dwell times, and the true negative decisions (TN) with the shortest (F = 50.552, p radiology.

  14. CLINICAL SURFACES - Activity-Based Computing for Distributed Multi-Display Environments in Hospitals

    Science.gov (United States)

    Bardram, Jakob E.; Bunde-Pedersen, Jonathan; Doryab, Afsaneh; Sørensen, Steffen

    A multi-display environment (MDE) is made up of co-located and networked personal and public devices that form an integrated workspace enabling co-located group work. Traditionally, MDEs have, however, mainly been designed to support a single “smart room”, and have had little sense of the tasks and activities that the MDE is being used for. This paper presents a novel approach to support activity-based computing in distributed MDEs, where displays are physically distributed across a large building. CLINICAL SURFACES was designed for clinical work in hospitals, and enables context-sensitive retrieval and browsing of patient data on public displays. We present the design and implementation of CLINICAL SURFACES, and report from an evaluation of the system at a large hospital. The evaluation shows that using distributed public displays to support activity-based computing inside a hospital is very useful for clinical work, and that the apparent contradiction between maintaining privacy of medical data in a public display environment can be mitigated by the use of CLINICAL SURFACES.

  15. Visualization and computer graphics on isotropically emissive volumetric displays.

    Science.gov (United States)

    Mora, Benjamin; Maciejewski, Ross; Chen, Min; Ebert, David S

    2009-01-01

    The availability of commodity volumetric displays provides ordinary users with a new means of visualizing 3D data. Many of these displays are in the class of isotropically emissive light devices, which are designed to directly illuminate voxels in a 3D frame buffer, producing X-ray-like visualizations. While this technology can offer intuitive insight into a 3D object, the visualizations are perceptually different from what a computer graphics or visualization system would render on a 2D screen. This paper formalizes rendering on isotropically emissive displays and introduces a novel technique that emulates traditional rendering effects on isotropically emissive volumetric displays, delivering results that are much closer to what is traditionally rendered on regular 2D screens. Such a technique can significantly broaden the capability and usage of isotropically emissive volumetric displays. Our method takes a 3D dataset or object as the input, creates an intermediate light field, and outputs a special 3D volume dataset called a lumi-volume. This lumi-volume encodes approximated rendering effects in a form suitable for display with accumulative integrals along unobtrusive rays. When a lumi-volume is fed directly into an isotropically emissive volumetric display, it creates a 3D visualization with surface shading effects that are familiar to the users. The key to this technique is an algorithm for creating a 3D lumi-volume from a 4D light field. In this paper, we discuss a number of technical issues, including transparency effects due to the dimension reduction and sampling rates for light fields and lumi-volumes. We show the effectiveness and usability of this technique with a selection of experimental results captured from an isotropically emissive volumetric display, and we demonstrate its potential capability and scalability with computer-simulated high-resolution results.

  16. Super high precision 200 ppi liquid crystal display series; Chokoseido 200 ppi ekisho display series

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    In mobile equipment, in demand is a high precision liquid crystal display (LCD) having the power of expression equivalent to printed materials like magazines because of the necessity of displaying a large amount of information on a easily potable small screen. In addition, with the spread and high-quality image of digital still cameras, it is strongly desired to display photographed digital image data in high quality. Toshiba Corp., by low temperature polysilicone (p-Si) technology, commercialized the liquid crystal display series of 200 ppi (pixels per inch) precision dealing with the rise of the high-precision high-image quality LCD market. The super high precision of 200 ppi enables the display of smooth beautiful animation comparable to printed sheets of magazines and photographs. The display series are suitable for the display of various information services such as electronic books and electronic photo-viewers including internet. The screen sizes lined up are No. 4 type VGA (640x480 pixels) of a small pocket notebook size and No. 6.3 type XGA (1,024x768 pixels) of a paperback size, with a larger screen to be furthered. (translated by NEDO)

  17. A Compressive Superresolution Display

    KAUST Repository

    Heide, Felix; Gregson, James; Wetzstein, Gordon; Raskar, Ramesh; Heidrich, Wolfgang

    2014-01-01

    In this paper, we introduce a new compressive display architecture for superresolution image presentation that exploits co-design of the optical device configuration and compressive computation. Our display allows for superresolution, HDR, or glasses-free 3D presentation.

  18. A Compressive Superresolution Display

    KAUST Repository

    Heide, Felix

    2014-06-22

    In this paper, we introduce a new compressive display architecture for superresolution image presentation that exploits co-design of the optical device configuration and compressive computation. Our display allows for superresolution, HDR, or glasses-free 3D presentation.

  19. Ultra-realistic imaging: a new beginning for display holography

    Science.gov (United States)

    Bjelkhagen, Hans I.; Brotherton-Ratcliffe, David

    2014-02-01

    Recent improvements in key foundation technologies are set to potentially transform the field of Display Holography. In particular new recording systems, based on recent DPSS and semiconductor lasers combined with novel recording materials and processing, have now demonstrated full-color analogue holograms of both lower noise and higher spectral accuracy. Progress in illumination technology is leading to a further major reduction in display noise and to a significant increase of the clear image depth and brightness of such holograms. So too, recent progress in 1-step Direct-Write Digital Holography (DWDH) now opens the way to the creation of High Virtual Volume Displays (HVV) - large format full-parallax DWDH reflection holograms having fundamentally larger clear image depths. In a certain fashion HVV displays can be thought of as providing a high quality full-color digital equivalent to the large-format laser-illuminated transmission holograms of the sixties and seventies. Back then, the advent of such holograms led to much optimism for display holography in the market. However, problems with laser illumination, their monochromatic analogue nature and image noise are well cited as being responsible for their failure in reality. Is there reason for believing that the latest technology improvements will make the mark this time around? This paper argues that indeed there is.

  20. JTEC panel on display technologies in Japan

    Science.gov (United States)

    Tannas, Lawrence E., Jr.; Glenn, William E.; Credelle, Thomas; Doane, J. William; Firester, Arthur H.; Thompson, Malcolm

    1992-01-01

    This report is one in a series of reports that describes research and development efforts in Japan in the area of display technologies. The following are included in this report: flat panel displays (technical findings, liquid crystal display development and production, large flat panel displays (FPD's), electroluminescent displays and plasma panels, infrastructure in Japan's FPD industry, market and projected sales, and new a-Si active matrix liquid crystal display (AMLCD) factory); materials for flat panel displays (liquid crystal materials, and light-emissive display materials); manufacturing and infrastructure of active matrix liquid crystal displays (manufacturing logistics and equipment); passive matrix liquid crystal displays (LCD basics, twisted nematics LCD's, supertwisted nematic LCD's, ferroelectric LCD's, and a comparison of passive matrix LCD technology); active matrix technology (basic active matrix technology, investment environment, amorphous silicon, polysilicon, and commercial products and prototypes); and projection displays (comparison of Japanese and U.S. display research, and technical evaluation of work).

  1. The understanding and self-reported use of emotional display rules in children with autism spectrum disorders

    NARCIS (Netherlands)

    Begeer, S.M.; Banerjee, R.; Rieffe, C.; Meerum Terwogt, M.; Potharst, E.; Stegge, G.T.M.; Koot, H.M.

    2011-01-01

    Two studies examined the understanding and self-reported use of rules for the expressive display of emotions in children with high functioning autism spectrum disorders (HFASD) and in typically developing children. In Study 1, children from the two groups reported display rules equally often when

  2. TRISTAR I: Evaluation Methods for Testing Head-Up Display (HUD) Flight Symbology

    National Research Council Canada - National Science Library

    Newman, R

    1995-01-01

    A piloted head up display (HUD) flight symbology study (TRISTAR) measuring pilot task performance was conducted at the NASA Ames Research Center by the Tri-Service Flight Symbology Working Group (FSWO...

  3. The understanding and self-reported use of emotional display rules in children with autism spectrum disorders.

    Science.gov (United States)

    Begeer, Sander; Banerjee, Robin; Rieffe, Carolien; Terwogt, Mark Meerum; Potharst, Eva; Stegge, Hedy; Koot, Hans M

    2011-08-01

    Two studies examined the understanding and self-reported use of rules for the expressive display of emotions in children with high functioning autism spectrum disorders (HFASD) and in typically developing children. In Study 1, children from the two groups reported display rules equally often when presented with hypothetical situations that provided clear motives for using display rules, although emotion-masking displays were more commonly identified for vignettes with prosocial rather than self-protective motives. In Study 2, children were interviewed about display rule use in real life. Children with HFASD reported display rules less often, included more prototypical examples, and referred less often to prosocial motives than typically developing children. Children with HFASD appear to be aware of display rules, but are less adept at identifying the interpersonal functions of such rules than their typically developing peers.

  4. Australian Children's Understanding of Display Rules

    Science.gov (United States)

    Choy, Grace

    2009-01-01

    Cultural display rules govern the manifestation of emotional expressions. In compliance with display rules, the facial expressions displayed (i.e. apparent emotion) may be incongruent with the emotion experienced (i.e. real emotion). This study investigates Australian Caucasian children's understanding of display rules. A sample of 80 four year…

  5. The case for transparent depth display

    NARCIS (Netherlands)

    Kooi, F.L.

    2003-01-01

    Purpose: The continuing developments in display technology have resulted in the ability to present increasing amounts of data on computer displays. One of the coming break-throughs is generally believed to be the introduction of '3-D displays': displays with a true sense of depth. Though these types

  6. Physiological Costs of Repetitive Courtship Displays in Cockroaches Handicap Locomotor Performance

    Science.gov (United States)

    Mowles, Sophie L.; Jepson, Natalie M.

    2015-01-01

    Courtship displays are typically thought to have evolved via female choice, whereby females select mates based on the characteristics of a display that is expected to honestly reflect some aspect of the male’s quality. Honesty is typically enforced by mechanistic costs and constraints that limit the level at which a display can be performed. It is becoming increasingly apparent that these costs may be energetic costs involved in the production of dynamic, often repetitive displays. A female attending to such a display may thus be assessing the physical fitness of a male as an index of his quality. Such assessment would provide information on his current physical quality as well as his ability to carry out other demanding activities, qualities with which a choosy female should want to provision her offspring. In the current study we use courtship interactions in the Cuban burrowing cockroach, Byrsotria fumigata to directly test whether courtship is associated with a signaler’s performance capacity. Males that had produced courtship displays achieved significantly lower speeds and distances in locomotor trials than non-courting control males. We also found that females mated more readily with males that produced a more vigorous display. Thus, males of this species have developed a strategy where they produce a demanding courtship display, while females choose males based on their ability to produce this display. Courtship displays in many taxa often involve dynamic repetitive actions and as such, signals of stamina in courtship may be more widespread than previously thought. PMID:26606147

  7. New ultraportable display technology and applications

    Science.gov (United States)

    Alvelda, Phillip; Lewis, Nancy D.

    1998-08-01

    MicroDisplay devices are based on a combination of technologies rooted in the extreme integration capability of conventionally fabricated CMOS active-matrix liquid crystal display substrates. Customized diffraction grating and optical distortion correction technology for lens-system compensation allow the elimination of many lenses and systems-level components. The MicroDisplay Corporation's miniature integrated information display technology is rapidly leading to many new defense and commercial applications. There are no moving parts in MicroDisplay substrates, and the fabrication of the color generating gratings, already part of the CMOS circuit fabrication process, is effectively cost and manufacturing process-free. The entire suite of the MicroDisplay Corporation's technologies was devised to create a line of application- specific integrated circuit single-chip display systems with integrated computing, memory, and communication circuitry. Next-generation portable communication, computer, and consumer electronic devices such as truly portable monitor and TV projectors, eyeglass and head mounted displays, pagers and Personal Communication Services hand-sets, and wristwatch-mounted video phones are among the may target commercial markets for MicroDisplay technology. Defense applications range from Maintenance and Repair support, to night-vision systems, to portable projectors for mobile command and control centers.

  8. "It Looks Like an Adult Sweetie Shop": Point-of-Sale Tobacco Display Exposure and Brand Awareness in Scottish Secondary School Students.

    Science.gov (United States)

    van der Sluijs, Winfried; Haseen, Farhana; Miller, Martine; MacGregor, Andy; Sharp, Clare; Amos, Amanda; Best, Catherine; Stead, Martine; Eadie, Douglas; Pearce, Jamie; Frank, John; Haw, Sally

    2016-10-01

    As further restrictions have been placed on tobacco advertising and promotions, point-of-sale (PoS) displays of cigarettes in shops have become an increasingly important source of young people's exposure to tobacco products. This study explored the relationship between PoS displays of cigarettes and brand awareness among secondary school students in Scotland. Cross-sectional school surveys (n = 1406) and focus groups (n = 86) were conducted with S2 (13-14 years) and S4 (15-16 years) students in four schools of differing socioeconomic status in 2013, prior to the PoS display ban in large shops. Adjusted negative binomial regression analysis examined associations between brand awareness and exposure variables (visiting tobacco retailers, noticing displays of tobacco products). Students visiting small shops more frequently (relative rate ratio [RRR] 1.19, 95% confidence interval [CI] 1.01-1.41) and those who noticed cigarette displays in small shops (RRR 1.24, 95% CI 1.03-1.51) and large supermarkets (RRR 1.15, 95% CI 1.01-1.30) had higher brand awareness. The focus groups supported these findings. Participants described PoS tobacco displays as being eye-catching, colorful and potentially attractive to young people. This mixed-methods study showed that higher cigarette brand awareness was significantly associated with regularly visiting small shops and noticing PoS displays in small and large shops, even when students' smoking status, smoking in their social networks, leisure activities, and demographics were included as confounding variables. This highlights the importance of PoS displays of tobacco products in increasing brand awareness, which is known to increase youth smoking susceptibility, and thus the importance of implementing PoS display bans in all shops. As increasing restrictions have been placed on tobacco promotion in many countries, PoS displays of cigarettes in shops have become an important source of young people's exposure to tobacco products and

  9. Bibliographic Displays in OPACs and Web Catalogs: How Well Do They Comply with Display Guidelines?

    Science.gov (United States)

    Cherry, Joan M.

    1998-01-01

    Evaluation of data from assessments of full bibliographic displays in academic library OPACs (online public access catalogs) and World Wide Web catalogs against a checklist of desirable features found that OPAC displays scored 58% and Web displays scored 60%. Discusses weaknesses, focusing on those found in the majority of the displays…

  10. A nanobody:GFP bacterial platform that enables functional enzyme display and easy quantification of display capacity

    DEFF Research Database (Denmark)

    Wendel, Sofie; Christian Fischer, Emil; Martinez, Virginia

    2016-01-01

    Background: Bacterial surface display is an attractive technique for the production of cell-anchored, functional proteins and engineering of whole-cell catalysts. Although various outer membrane proteins have been used for surface display, an easy and versatile high-throughput-compatible assay...... to displaying the nanobody alone. We used flow cytometry to analyse display capability on single-cell versus population level and found that the signal peptide of the anchor has great effect on display efficiency.Conclusions: We have developed an inexpensive and easy read-out assay for surface display using...... nanobody: GFP interactions. The assay is compatible with the most common fluorescence detection methods, including multi-well plate whole-cell fluorescence detection, SDS-PAGE in-gel fluorescence, microscopy and flow cytometry. We anticipate that the platform will facilitate future in-depth studies...

  11. When authenticity matters most: Physicians' regulation of emotional display and patient satisfaction.

    Science.gov (United States)

    Yagil, Dana; Shnapper-Cohen, Moran

    2016-10-01

    The emotions expressed by physicians in medical encounters have significant impact on health outcomes and patient satisfaction. This study explored how physicians' regulation of displayed emotions affects patients' satisfaction, under low and high levels of patient distress and length of physician-patient acquaintance. Questionnaires were administered to 46 physicians and 230 of their patients (before and after the medical encounter) in outpatient clinics of two hospitals. Data were analyzed with hierarchical linear modeling which takes the nested data structure into account. We found a significant interaction effect of physician regulation of displayed emotions and patient distress on satisfaction: When distress was high, physician regulation of emotions was negatively related to patient satisfaction. The results also show a significant interaction effect of physician regulation of displayed emotions and length of physician-patient acquaintance: With a longer acquaintance, physician regulation of emotions was negatively related to patient satisfaction. The effect of the physicians' emotional display on patient satisfaction depends on contextual factors, such as patient distress and length of physician-patient acquaintance, which affect patients' emotional needs and expectations. When patients have high emotional involvement in the encounter it is suggested that physicians consider presenting genuine emotions to patients. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. Reconfigurable Full-Page Braille Displays

    Science.gov (United States)

    Garner, H. Douglas

    1994-01-01

    Electrically actuated braille display cells of proposed type arrayed together to form full-page braille displays. Like other braille display cells, these provide changeable patterns of bumps driven by digitally recorded text stored on magnetic tapes or in solid-state electronic memories. Proposed cells contain electrorheological fluid. Viscosity of such fluid increases in strong electrostatic field.

  13. Temporal lobe epileptic signs and correlative behaviors displayed by normal populations.

    Science.gov (United States)

    Persinger, M A; Makarec, K

    1987-04-01

    With regard to epileptic signs and correlative behaviors, one hypothesis is that the experiences and nonconvulsive behaviors of patients with electrical foci within the temporal lobe are also displayed, but with less intensity, by normal people. If this is correct, then there should be quantitative relationships between the numbers of major complex partial epileptic signs (CPES) and the occurrence of other frequent clinical experiences and behaviors. An inventory to answer this question was developed. Over a 3-year period, 414 (6 groups) university students were administered an inventory that included themes of CPES as well as control and information items. Strong correlations were consistently found between CPES scores and reports of paranormal (mystical, with religious overtones) experiences and "a sense of presence." Results from three personality (CPI, MMPI, and IPAT anxiety) inventories clearly demonstrated similar profiles. In addition to being more anxious, people who displayed higher CPES scores were more suspicious, aloof, stereotyped in their behavior, ruminative (overthinking), intellectually inefficient, and overly judgmental. CPES scores were significantly (p less than .001) correlated with the schizophrenia and mania subscales of the MMPI. The results suggest that functional hyperconnectionism of cortical-limbic systems within the brain may be more prevalent in the normal population than previously suspected.

  14. Display-management system for MFTF

    International Nuclear Information System (INIS)

    Nelson, D.O.

    1981-01-01

    The Mirror Fusion Test Facility (MFTF) is controlled by 65 local control microcomputers which are supervised by a local network of nine 32-bit minicomputers. Associated with seven of the nine computers are state-of-the-art graphics devices, each with extensive local processing capability. These devices provide the means for an operator to interact with the control software running on the minicomputers. It is critical that the information the operator views accurately reflects the current state of the experiment. This information is integrated into dynamically changing pictures called displays. The primary organizational component of the display system is the software-addressable segment. The segments created by the display creation software are managed by display managers associated with each graphics device. Each display manager uses sophisticated storage management mechanisms to keep the proper segments resident in the local graphics device storage

  15. Data display with the Q system

    International Nuclear Information System (INIS)

    Oothoudt, M.A.

    1979-01-01

    The Q data-acquisition system for PDP-11 mini-computers at the Clinton P. Anderson Meson Physics Facility (LAMPF) provides experimenters with basic tools for on-line data display. Tasks are available to plot one- and two-parameter histograms on Tektronix 4000 series storage-tube terminals. The histograms to be displayed and the display format may be selected with simple keyboard commands. A task is also available to create and display live two-parameter scatter plots for any acquired or calculated quantities. Other tasks in the system manage the display data base, list display parameters and histogram contents on hardcopy devices, and save core histograms on disk or tape for off-line analysis. 8 figures

  16. Two dimensional polar display of cardiac blood pool SPECT

    International Nuclear Information System (INIS)

    Honda, Norinari; Machida, Kikuo; Mamiya, Toshio; Takahashi, Taku; Takishima, Teruo; Hasegawa, Noriko; Hashimoto, Masanori; Ohno, Ken

    1989-01-01

    A new method of ECG gated cardiac blood pool SPECT to illustrate the left ventricular (LV) wall motion in a single static image, two dimensional polar display (2DPD), was described. Circumferential profiles of the difference between end diastolic and end systolic short axis images of the LV were displayed in a similar way to the bull's eye plot of 201 Tl myocardial SPECT. The diagnoses by 2DPDs agreed with those by cinematic displays of ECG gated blood pool SPECT in 74 out of 84 segments (85.5%) of abnormal motion, and 155 out of 168 segments (80.3%) of normal motion. It is concluded that 2DPD can evaluate regional wall motion by a single static image in a significant number of patients, and is also useful in comparing with the bull's eye image of 201 Tl myorcardial SPECT. (orig.)

  17. Treating student contributions as displays of understanding in group supervision

    DEFF Research Database (Denmark)

    Day, Dennis; Kjærbeck, Susanne

    2012-01-01

    The analyses this paper reports come from ongoing research into the interactive establishment of local social order in an educational setting (Day & Kjærbeck 2008, Day & Kjærbeck, in preparation). In focus for this paper are a particular sort of activity in the setting, 'group supervision', where...

  18. A nanobody:GFP bacterial platform that enables functional enzyme display and easy quantification of display capacity.

    Science.gov (United States)

    Wendel, Sofie; Fischer, Emil C; Martínez, Virginia; Seppälä, Susanna; Nørholm, Morten H H

    2016-05-03

    Bacterial surface display is an attractive technique for the production of cell-anchored, functional proteins and engineering of whole-cell catalysts. Although various outer membrane proteins have been used for surface display, an easy and versatile high-throughput-compatible assay for evaluating and developing surface display systems is missing. Using a single domain antibody (also called nanobody) with high affinity for green fluorescent protein (GFP), we constructed a system that allows for fast, fluorescence-based detection of displayed proteins. The outer membrane hybrid protein LppOmpA and the autotransporter C-IgAP exposed the nanobody on the surface of Escherichia coli with very different efficiency. Both anchors were capable of functionally displaying the enzyme Chitinase A as a fusion with the nanobody, and this considerably increased expression levels compared to displaying the nanobody alone. We used flow cytometry to analyse display capability on single-cell versus population level and found that the signal peptide of the anchor has great effect on display efficiency. We have developed an inexpensive and easy read-out assay for surface display using nanobody:GFP interactions. The assay is compatible with the most common fluorescence detection methods, including multi-well plate whole-cell fluorescence detection, SDS-PAGE in-gel fluorescence, microscopy and flow cytometry. We anticipate that the platform will facilitate future in-depth studies on the mechanism of protein transport to the surface of living cells, as well as the optimisation of applications in industrial biotech.

  19. iFlit: an ambient display to induce cognitive dissonance and behaviour change

    Directory of Open Access Journals (Sweden)

    R. Maimone

    2014-03-01

    Full Text Available In this paper, we explore how persuasive ambient displays could induce cognitive dissonance to promote positive behaviour change among graduate students. We developed iFlit –an interactive and collective ambient display that enables a group of students to reflect on their burnout level, and sleeping and activity habits. iFlit shows a garden with birds representing students monitored behaviour. Birds move according to users’ activity level, and the garden’s background changes according to each user’s sleeping habits. Users match peers perceived burnout, and sleep and activity habits to induce cognitive dissonance. We argue such displays are more efficient than personal devices to empower individuals’ self-reflection due their capabilities for enabling a playful interaction with their personal data.

  20. Comparison of optical see-through head-mounted displays for surgical interventions with object-anchored 2D-display.

    Science.gov (United States)

    Qian, Long; Barthel, Alexander; Johnson, Alex; Osgood, Greg; Kazanzides, Peter; Navab, Nassir; Fuerst, Bernhard

    2017-06-01

    Optical see-through head-mounted displays (OST-HMD) feature an unhindered and instantaneous view of the surgery site and can enable a mixed reality experience for surgeons during procedures. In this paper, we present a systematic approach to identify the criteria for evaluation of OST-HMD technologies for specific clinical scenarios, which benefit from using an object-anchored 2D-display visualizing medical information. Criteria for evaluating the performance of OST-HMDs for visualization of medical information and its usage are identified and proposed. These include text readability, contrast perception, task load, frame rate, and system lag. We choose to compare three commercially available OST-HMDs, which are representatives of currently available head-mounted display technologies. A multi-user study and an offline experiment are conducted to evaluate their performance. Statistical analysis demonstrates that Microsoft HoloLens performs best among the three tested OST-HMDs, in terms of contrast perception, task load, and frame rate, while ODG R-7 offers similar text readability. The integration of indoor localization and fiducial tracking on the HoloLens provides significantly less system lag in a relatively motionless scenario. With ever more OST-HMDs appearing on the market, the proposed criteria could be used in the evaluation of their suitability for mixed reality surgical intervention. Currently, Microsoft HoloLens may be more suitable than ODG R-7 and Epson Moverio BT-200 for clinical usability in terms of the evaluated criteria. To the best of our knowledge, this is the first paper that presents a methodology and conducts experiments to evaluate and compare OST-HMDs for their use as object-anchored 2D-display during interventions.

  1. Conceptual Design of Industrial Process Displays

    DEFF Research Database (Denmark)

    Pedersen, C.R.; Lind, Morten

    1999-01-01

    discusses aspects of process display design taking into account both the designer's and the operator's points of view. Three aspects are emphasized: the operator tasks, the display content and the display form. The distinction between these three aspects is the basis for proposing an outline for a display......Today, process displays used in industry are often designed on the basis of piping and instrumentation diagrams without any method of ensuring that the needs of the operators are fulfilled. Therefore, a method for a systematic approach to the design of process displays is needed. This paper...... by a simple example from a plant with batch processes. Later the method is applied to develop a supervisory display for a condenser system in a nuclear power plant. The differences between the continuous plant domain of power production and the batch processes from the example are analysed and broad...

  2. Congenital malformations among children of women working with video display terminals

    DEFF Research Database (Denmark)

    Brandt, L P; Nielsen, C V

    1990-01-01

    In a case-base study among 214,108 commercial and clerical employees in Denmark the potential effect of the use of video display terminals on the risk of congenital malformations in pregnancy was investigated. The study base was identified by means of register linkage of the Medical Birth Register...... and the National Register of In-Patients. In the source population 24,352 pregnancy outcomes were registered, 661 of which with congenital malformations entered the case group, and a base sample of 2252 pregnancies was drawn. Data concerning the use of video display terminals, job stress, ergonomic factors......, exposure to organic solvents, and life-style factors were obtained from postal questionnaires. The results of this study did not support the hypothesis that the use of video display terminals during pregnancy is associated with an increased risk of congenital malformations....

  3. The Effect of Programmable Tactile Displays on Spatial Learning Skills in Children and Adolescents of Different Visual Disability.

    Science.gov (United States)

    Leo, Fabrizio; Cocchi, Elena; Brayda, Luca

    2017-07-01

    Vision loss has severe impacts on physical, social and emotional well-being. The education of blind children poses issues as many scholar disciplines (e.g., geometry, mathematics) are normally taught by heavily relying on vision. Touch-based assistive technologies are potential tools to provide graphical contents to blind users, improving learning possibilities and social inclusion. Raised-lines drawings are still the golden standard, but stimuli cannot be reconfigured or adapted and the blind person constantly requires assistance. Although much research concerns technological development, little work concerned the assessment of programmable tactile graphics, in educative and rehabilitative contexts. Here we designed, on programmable tactile displays, tests aimed at assessing spatial memory skills and shapes recognition abilities. Tests involved a group of blind and a group of low vision children and adolescents in a four-week longitudinal schedule. After establishing subject-specific difficulty levels, we observed a significant enhancement of performance across sessions and for both groups. Learning effects were comparable to raised paper control tests: however, our setup required minimal external assistance. Overall, our results demonstrate that programmable maps are an effective way to display graphical contents in educative/rehabilitative contexts. They can be at least as effective as traditional paper tests yet providing superior flexibility and versatility.

  4. Evaluation of force-torque displays for use with space station telerobotic activities

    Science.gov (United States)

    Hendrich, Robert C.; Bierschwale, John M.; Manahan, Meera K.; Stuart, Mark A.; Legendre, A. Jay

    1992-01-01

    Recent experiments which addressed Space Station remote manipulation tasks found that tactile force feedback (reflecting forces and torques encountered at the end-effector through the manipulator hand controller) does not improve performance significantly. Subjective response from astronaut and non-astronaut test subjects indicated that force information, provided visually, could be useful. No research exists which specifically investigates methods of presenting force-torque information visually. This experiment was designed to evaluate seven different visual force-torque displays which were found in an informal telephone survey. The displays were prototyped in the HyperCard programming environment. In a within-subjects experiment, 14 subjects nullified forces and torques presented statically, using response buttons located at the bottom of the screen. Dependent measures included questionnaire data, errors, and response time. Subjective data generally demonstrate that subjects rated variations of pseudo-perspective displays consistently better than bar graph and digital displays. Subjects commented that the bar graph and digital displays could be used, but were not compatible with using hand controllers. Quantitative data show similar trends to the subjective data, except that the bar graph and digital displays both provided good performance, perhaps do to the mapping of response buttons to display elements. Results indicate that for this set of displays, the pseudo-perspective displays generally represent a more intuitive format for presenting force-torque information.

  5. Helmet-Mounted Display Design Guide

    Science.gov (United States)

    1997-11-03

    on openStack create menu "CSHMD" set the menuitems of "CSHMD" to "(Main Menu; References;-; Definitions;Display Criteria;Display Formats;Display Modes...34Macintosh" then put ":" into dirSep else put "V’ into dirSep put stackPathO&"Resource"&dirSep into gResPath put 0 into gXRef end openStack on

  6. Ruggedized Full-Color Flexible OLED Display

    National Research Council Canada - National Science Library

    Hack, Michael

    2003-01-01

    .... The team comprised Universal Display Corporation, Princeton University, the University of Southern California, Penn State University, L3 Displays and Vitex Systems, and was led by Universal Display Corporation (PI: Michael Hack...

  7. Potentials and limits of electronic situation displays

    International Nuclear Information System (INIS)

    Hable, K.; Hoebler, C.; Bieringer, P.

    2007-01-01

    In the field of precautionary radiation protection and disaster response, the amount of information and the number of its sources is steadily increasing. Central compilation and instant availability of information for all involved authorities becomes more and more important. In this context the structured presentation of documents on a web server in terms of an ''Electronic Situation Display'' (ESD) has been established. In Germany, there are several Electronic Situation Display prototypes run by federal and state authorities for various purposes and using different technical approaches. The systems of the federal states focus on workflow management. They provide emergency log books and information on the implementation of countermeasures for disaster response authorities. The Federal Ministry for the Environment, Nature Conservation and Nuclear Safety (BMU) tasked the Federal Office for Radiation Protection (BfS) to develop the Federal Electronic Situation Display (ELAN) that is mainly used as an information platform for decision making in case of nuclear emergencies. Documents containing radiological data or results from Decision Support Systems are almost automatically integrated into ELAN. Read and write permissions for users are managed by a concept of specific roles. The federal ESD and the systems of the federal states will be coordinated in order to achieve a better harmonisation. Interfaces for data exchange and data processing must be defined. Authorities of the federal states can use protected areas within the federal ESD where information is kept confidential for internal use before it is distributed to other states and federal authorities. In addition, key information of Electronic Situation Displays from the federal states can automatically be integrated into ELAN. Several task groups of the IAEA are working on the development and realization of a prototype for an information platform harmonising ESDs on international level. (orig.)

  8. Diagnostic and Prognostic Significance of Serum and Tissue Galectin 3 Expression in Patients with Carcinoma of the Bladder

    Science.gov (United States)

    Gendy, Hoda El; Madkour, Bothina; Abdelaty, Sara; Essawy, Fayza; Khattab, Dina; Hammam, Olfat; Nour, Hani H.

    2014-01-01

    Background Galectins are group of proteins found in the cytoplasm, nucleus, cell surface and extracellular matrix. Galectin 3 (Gal-3) displays pathological expression in a variety of processes such as tumorigenesis. Patients and Method 70 patients classified into the control group, cystitis group, transitional cell carcinoma group, and squamous cell carcinoma group were enrolled in this study which aimed to detect the serum level and the intensity of tissue expression of Gal-3. Results Both serum level and tissue expression of Gal-3 were statistically higher in bladder cancer patients compared to the other groups. Gal-3 level expression increased from low to high grade urothelial tumors, with a statistically significant increase of its level and expression between muscle invasive and non-muscle invasive Ta urothelial tumors. Conclusion The serum Gal-3 level is sensitive and specific for the diagnosis of bladder cancer. The prognostic significance of tissue expression is to be confirmed. PMID:26195948

  9. A variable-collimation display system

    Science.gov (United States)

    Batchko, Robert; Robinson, Sam; Schmidt, Jack; Graniela, Benito

    2014-03-01

    Two important human depth cues are accommodation and vergence. Normally, the eyes accommodate and converge or diverge in tandem; changes in viewing distance cause the eyes to simultaneously adjust both focus and orientation. However, ambiguity between accommodation and vergence cues is a well-known limitation in many stereoscopic display technologies. This limitation also arises in state-of-the-art full-flight simulator displays. In current full-flight simulators, the out-the-window (OTW) display (i.e., the front cockpit window display) employs a fixed collimated display technology which allows the pilot and copilot to perceive the OTW training scene without angular errors or distortions; however, accommodation and vergence cues are limited to fixed ranges (e.g., ~ 20 m). While this approach works well for long-range, the ambiguity of depth cues at shorter range hinders the pilot's ability to gauge distances in critical maneuvers such as vertical take-off and landing (VTOL). This is the first in a series of papers on a novel, variable-collimation display (VCD) technology that is being developed under NAVY SBIR Topic N121-041 funding. The proposed VCD will integrate with rotary-wing and vertical take-off and landing simulators and provide accurate accommodation and vergence cues for distances ranging from approximately 3 m outside the chin window to ~ 20 m. A display that offers dynamic accommodation and vergence could improve pilot safety and training, and impact other applications presently limited by lack of these depth cues.

  10. Combat vehicle crew helmet-mounted display: next generation high-resolution head-mounted display

    Science.gov (United States)

    Nelson, Scott A.

    1994-06-01

    The Combat Vehicle Crew Head-Mounted Display (CVC HMD) program is an ARPA-funded, US Army Natick Research, Development, and Engineering Center monitored effort to develop a high resolution, flat panel HMD for the M1 A2 Abrams main battle tank. CVC HMD is part of the ARPA High Definition Systems (HDS) thrust to develop and integrate small (24 micrometers square pels), high resolution (1280 X 1024 X 6-bit grey scale at 60 frame/sec) active matrix electroluminescent (AMEL) and active matrix liquid crystal displays (AMLCD) for head mounted and projection applications. The Honeywell designed CVC HMD is a next generation head-mounted display system that includes advanced flat panel image sources, advanced digital display driver electronics, high speed (> 1 Gbps) digital interconnect electronics, and light weight, high performance optical and mechanical designs. The resulting dramatic improvements in size, weight, power, and cost have already led to program spin offs for both military and commercial applications.

  11. Geographic Information Systems: Tools for Displaying In-Library Use Data

    Directory of Open Access Journals (Sweden)

    Lauren H. Mandel

    2010-03-01

    Full Text Available In-library use data is crucial for modern libraries to understand the full spectrum of patron use, including patron self-service activities, circulation, and reference statistics. Rather than using tables and charts to display use data, a geographic information system (GIS facilitates a more visually appealing graphical display of the data in the form of a map. GISs have been used by library and information science (LIS researchers and practitioners to create maps that display analyses of service area populations and demographics, facilities space management issues, spatial distribution of in-library use of materials, planned branch consolidations, and so on. The “seating sweeps” method allows researchers and librarians to collect in-library use data regarding where patrons are locating themselves within the library and what they are doing at those locations, such as sitting and reading, studying in a group, or socializing. This paper proposes a GIS as a tool to visually display in-library use data collected via “seating sweeps” of a library. By using a GIS to store, manage, and display the data, researchers and librarians can create visually appealing maps that show areas of heavy use and evidence of the use and value of the library for a community. Example maps are included to facilitate the reader’s understanding of the possibilities afforded by using GISs in LIS research.

  12. “It Looks Like an Adult Sweetie Shop”: Point-of-Sale Tobacco Display Exposure and Brand Awareness in Scottish Secondary School Students

    Science.gov (United States)

    van der Sluijs, Winfried; Miller, Martine; MacGregor, Andy; Sharp, Clare; Amos, Amanda; Best, Catherine; Stead, Martine; Eadie, Douglas; Pearce, Jamie; Frank, John; Haw, Sally

    2016-01-01

    Introduction: As further restrictions have been placed on tobacco advertising and promotions, point-of-sale (PoS) displays of cigarettes in shops have become an increasingly important source of young people’s exposure to tobacco products. This study explored the relationship between PoS displays of cigarettes and brand awareness among secondary school students in Scotland. Methods: Cross-sectional school surveys (n = 1406) and focus groups (n = 86) were conducted with S2 (13–14 years) and S4 (15–16 years) students in four schools of differing socioeconomic status in 2013, prior to the PoS display ban in large shops. Adjusted negative binomial regression analysis examined associations between brand awareness and exposure variables (visiting tobacco retailers, noticing displays of tobacco products). Results: Students visiting small shops more frequently (relative rate ratio [RRR] 1.19, 95% confidence interval [CI] 1.01–1.41) and those who noticed cigarette displays in small shops (RRR 1.24, 95% CI 1.03–1.51) and large supermarkets (RRR 1.15, 95% CI 1.01–1.30) had higher brand awareness. The focus groups supported these findings. Participants described PoS tobacco displays as being eye-catching, colorful and potentially attractive to young people. Conclusions: This mixed-methods study showed that higher cigarette brand awareness was significantly associated with regularly visiting small shops and noticing PoS displays in small and large shops, even when students’ smoking status, smoking in their social networks, leisure activities, and demographics were included as confounding variables. This highlights the importance of PoS displays of tobacco products in increasing brand awareness, which is known to increase youth smoking susceptibility, and thus the importance of implementing PoS display bans in all shops. Implications: As increasing restrictions have been placed on tobacco promotion in many countries, PoS displays of cigarettes in shops have become

  13. Visual ergonomic aspects of glare on computer displays: glossy screens and angular dependence

    Science.gov (United States)

    Brunnström, Kjell; Andrén, Börje; Konstantinides, Zacharias; Nordström, Lukas

    2007-02-01

    Recently flat panel computer displays and notebook computer are designed with a so called glare panel i.e. highly glossy screens, have emerged on the market. The shiny look of the display appeals to the costumers, also there are arguments that the contrast, colour saturation etc improves by using a glare panel. LCD displays suffer often from angular dependent picture quality. This has been even more pronounced by the introduction of Prism Light Guide plates into displays for notebook computers. The TCO label is the leading labelling system for computer displays. Currently about 50% of all computer displays on the market are certified according to the TCO requirements. The requirements are periodically updated to keep up with the technical development and the latest research in e.g. visual ergonomics. The gloss level of the screen and the angular dependence has recently been investigated by conducting user studies. A study of the effect of highly glossy screens compared to matt screens has been performed. The results show a slight advantage for the glossy screen when no disturbing reflexes are present, however the difference was not statistically significant. When disturbing reflexes are present the advantage is changed into a larger disadvantage and this difference is statistically significant. Another study of angular dependence has also been performed. The results indicates a linear relationship between the picture quality and the centre luminance of the screen.

  14. Acquisition of L2 Japanese Geminates: Training with Waveform Displays

    Directory of Open Access Journals (Sweden)

    Miki Motohashi-Saigo

    2009-06-01

    Full Text Available The value of waveform displays as visual feedback was explored in a training study involving perception and production of L2 Japanese by beginning-level L1 English learners. A pretest-posttest design compared auditory-visual (AV and auditory-only (A-only Web-based training. Stimuli were singleton and geminate /t,k,s/ followed by /a,u/ in two conditions (isolated words, carrier sentences. Fillers with long vowels were included. Participants completed a forced-choice identification task involving minimal triplets: singletons, geminates, long vowels (e.g., sasu, sassu, saasu. Results revealed a significant improvement in geminate identification following training, especially for AV; b significant effect of geminate (lowest scores for /s/; c no significant effect of condition; and d no significant improvement for the control group. Most errors were misperceptions of geminates as long vowels. Test of generalization revealed 5% decline in accuracy for AV and 14% for A-only. Geminate production improved significantly (especially for AV based on rater judgments; improvement was greatest for /k/ and smallest for /s/. Most production errors involved substitution of a singleton for a geminate. Post-study interviews produced positive comments on Web-based training. Waveforms increased awareness of durational differences. Results support the effectiveness of auditory-visual input in L2 perception training with transfer to novel stimuli and improved production.

  15. Basics of Antibody Phage Display Technology.

    Science.gov (United States)

    Ledsgaard, Line; Kilstrup, Mogens; Karatt-Vellatt, Aneesh; McCafferty, John; Laustsen, Andreas H

    2018-06-09

    Antibody discovery has become increasingly important in almost all areas of modern medicine. Different antibody discovery approaches exist, but one that has gained increasing interest in the field of toxinology and antivenom research is phage display technology. In this review, the lifecycle of the M13 phage and the basics of phage display technology are presented together with important factors influencing the success rates of phage display experiments. Moreover, the pros and cons of different antigen display methods and the use of naïve versus immunized phage display antibody libraries is discussed, and selected examples from the field of antivenom research are highlighted. This review thus provides in-depth knowledge on the principles and use of phage display technology with a special focus on discovery of antibodies that target animal toxins.

  16. Three-dimensional hologram display system

    Science.gov (United States)

    Mintz, Frederick (Inventor); Chao, Tien-Hsin (Inventor); Bryant, Nevin (Inventor); Tsou, Peter (Inventor)

    2009-01-01

    The present invention relates to a three-dimensional (3D) hologram display system. The 3D hologram display system includes a projector device for projecting an image upon a display medium to form a 3D hologram. The 3D hologram is formed such that a viewer can view the holographic image from multiple angles up to 360 degrees. Multiple display media are described, namely a spinning diffusive screen, a circular diffuser screen, and an aerogel. The spinning diffusive screen utilizes spatial light modulators to control the image such that the 3D image is displayed on the rotating screen in a time-multiplexing manner. The circular diffuser screen includes multiple, simultaneously-operated projectors to project the image onto the circular diffuser screen from a plurality of locations, thereby forming the 3D image. The aerogel can use the projection device described as applicable to either the spinning diffusive screen or the circular diffuser screen.

  17. The Design and Evaluation of the Lighting Imaging Sensor Data Applications Display (LISDAD)

    Science.gov (United States)

    Boldi, B.; Hodanish, S.; Sharp, D.; Williams, E.; Goodman, Steven; Raghavan, R.; Matlin, A.; Weber, M.

    1998-01-01

    The design and evaluation of the Lightning Imaging Sensor Data Applications Display (LISDAD). The ultimate goal of the LISDAD system is to quantify the utility of total lightning information in short-term, severe-weather forecasting operations. To this end, scientists from NASA, NWS, and MIT organized an effort to study the relationship of lightning and severe-weather on a storm-by-storm, and even cell-by-cell basis for as many storms as possible near Melbourne, Florida. Melbourne was chosen as it offers a unique combination of high probability of severe weather and proximity to major relevant sensors - specifically: NASA's total lightning mapping system at Kennedy Space Center (the LDAR system at KSC); a NWS/NEXRAD radar (at Melbourne); and a prototype Integrated Terminal Weather System (ITWS, at Orlando), which obtains cloud-to-ground lightning Information from the National Lightning Detection Network (NLDN), and also uses NSSL's Severe Storm Algorithm (NSSL/SSAP) to obtain information about various storm-cell parameters. To assist in realizing this project's goal, an interactive, real-time data processing system (the LISDAD system) has been developed that supports both operational short-term weather forecasting and post facto severe-storm research. Suggestions have been drawn from the operational users (NWS/Melbourne) in the design of the data display and its salient behavior. The initial concept for the users Graphical Situation Display (GSD) was simply to overlay radar data with lightning data, but as the association between rapid upward trends in the total lightning rate and severe weather became evident, the display was significantly redesigned. The focus changed to support the display of time series of storm-parameter data and the automatic recognition of cells that display rapid changes in the total-lightning flash rate. The latter is calculated by grouping discrete LDAR radiation sources into lightning flashes using a time-space association algorithm

  18. The multikinase inhibitor Sorafenib displays significant antiproliferative effects and induces apoptosis via caspase 3, 7 and PARP in B- and T-lymphoblastic cells

    International Nuclear Information System (INIS)

    Schult, Catrin; Boldt, Sonja; Wolkenhauer, Olaf; Neri, Luca Maria; Freund, Mathias; Junghanss, Christian; Dahlhaus, Meike; Ruck, Sabine; Sawitzky, Mandy; Amoroso, Francesca; Lange, Sandra; Etro, Daniela; Glass, Aenne; Fuellen, Georg

    2010-01-01

    Targeted therapy approaches have been successfully introduced into the treatment of several cancers. The multikinase inhibitor Sorafenib has antitumor activity in solid tumors and its effects on acute lymphoblastic leukemia (ALL) cells are still unclear. ALL cell lines (SEM, RS4;11 and Jurkat) were treated with Sorafenib alone or in combination with cytarabine, doxorubicin or RAD001. Cell count, apoptosis and necrosis rates, cell cycle distribution, protein phosphorylation and metabolic activity were determined. Sorafenib inhibited the proliferation of ALL cells by cell cycle arrest accompanied by down-regulation of CyclinD3 and CDK4. Furthermore, Sorafenib initiated apoptosis by cleavage of caspases 3, 7 and PARP. Apoptosis and necrosis rates increased significantly with most pronounced effects after 96 h. Antiproliferative effects of Sorafenib were associated with a decreased phosphorylation of Akt (Ser473 and Thr308), FoxO3A (Thr32) and 4EBP-1 (Ser65 and Thr70) as early as 0.5 h after treatment. Synergistic effects were seen when Sorafenib was combined with other cytotoxic drugs or a mTOR inhibitor emphasizing the Sorafenib effect. Sorafenib displays significant antileukemic activity in vitro by inducing cell cycle arrest and apoptosis. Furthermore, it influences PI3K/Akt/mTOR signaling in ALL cells

  19. An Adaptive Display to Treat Stress-Related Disorders: EMMA's World

    Science.gov (United States)

    Banos, R. M.; Botella, C.; Guillen, V.; Garcia-Palacios, A.; Quero, S.; Breton-Lopez, J.; Alcaniz, M.

    2009-01-01

    Most of the virtual environments currently available in the field of psychological treatments were designed to solve a specific problem. Our research group has developed a versatile virtual reality system (an adaptive display) called "EMMA's world", which can address a wide range of problems. It was designed to assist in clinical situations where…

  20. Display rules versus display autonomy: emotion regulation, emotional exhaustion, and task performance in a call center simulation.

    Science.gov (United States)

    Goldberg, Lori Sideman; Grandey, Alicia A

    2007-07-01

    "Service with a smile" is satisfying for the customer, but such display rules may be costly to the employee and the organization. Most previous research on such costs has used self-reported and cross-sectional designs. The authors use an experimental approach to test tenets of resource depletion theories; specifically, whether the self-regulation of emotions required by display rules depletes energy and attentional resources during a service encounter. Using a call center simulation with three "customer" interactions, the authors found that participants given positive display rules (e.g., be enthusiastic and hide frustration) reported more postsimulation exhaustion and made more errors on the order form compared to those with display autonomy. Customer hostility during one of the calls also increased exhaustion overall and the number of errors during that specific call, though proposed interactions with display rules were not supported. Surface-level emotion regulation, but not deep-level, was the mechanism for the energy depletion effect of display rules, while display rules had a direct effect on performance decrements. Theoretical and practical implications for display rules as part of job requirements are discussed. Copyright 2007 APA

  1. Paediatric dose display

    International Nuclear Information System (INIS)

    Griffin, D.W.; Derges, S.; Hesslewood, S.

    1984-01-01

    A compact, inexpensive unit, based on an 8085 microprocessor, has been designed for calculating doses of intravenous radioactive injections for children. It has been used successfully for over a year. The dose is calculated from the body surface area and the result displayed in MBq. The operator can obtain the required dose on a twelve character alphanumeric display by entering the age of the patient and the adult dose using a hexadecimal keyboard. Circuit description, memory map and input/output, and firmware are dealt with. (U.K.)

  2. Tactile Scanning and Memory for a Spatial Display by Blind Students.

    Science.gov (United States)

    Berla, Edward P.

    1981-01-01

    Thirty-six braille students (grades 4 through 12) were asked to inspect a tactile display consisting of nine removable symbols. Students in the lower grades benefited most from the systematic searching training and were superior to the control group in the same grades. (Author)

  3. Scaling Robotic Displays: Displays and Techniques for Dismounted Movement with Robots

    Science.gov (United States)

    2010-04-01

    you are performing the low crawl 4.25 5.00 Drive the robot while you are negotiating the hill 6.00 5.00 Drive the robot while you are climbing the... stairs 4.67 5.00 Drive the robot while you are walking 5.70 5.27 HMD It was fairly doable. 1 When you’re looking through the lens, it’s not...Scaling Robotic Displays: Displays and Techniques for Dismounted Movement with Robots by Elizabeth S. Redden, Rodger A. Pettitt

  4. Liquid crystal displays with plastic substrates

    Science.gov (United States)

    Lueder, Ernst H.

    1998-04-01

    Plastic substrates for the cells of displays exhibit only 1/6 of the weight of glass substrates; they are virtually unbreakable; their flexibility allows the designer to give them a shape suppressing reflections, to realize a display board on a curved surface or meeting the requirements for an appealing styling; displays with plastics are thinner which provides a wider viewing angle. These features render them attractive for displays in portable systems such as mobile phones, pagers, smart cards, personal digital assistants (PDAs) and portable computers. Reflective displays are especially attractive as they don't need a back light. The most important requirements are the protection of plastics against gas permeation and chemical agents, the prevention of layers on plastics to crack or peel off when the plastic is bent and the development of low temperature thin film processes because the plastics, as a rule, only tolerate temperatures below 150 degrees Celsius. Bistable reflective FLC- and PSCT-displays with plastic substrates will be introduced. Special sputtered SiO2-orientation layers preserve the displayed information even if pressure or torsion is applied. MIM-addressed PDLC-displays require additional Al- or Ti-layers which provide the necessary ductility. Sputtered or PECVD-generated TFTs can be fabricated on plastics at temperatures below 150 degrees Celsius.

  5. Plant state display device

    International Nuclear Information System (INIS)

    Kadota, Kazuo; Ito, Toshiichiro.

    1994-01-01

    The device of the present invention conducts information processing suitable for a man to solve a problem in a plant such as a nuclear power plant incorporating a great amount of information, where safety is required and provides information to an operator. Namely, theories and rules with respect to the flow and balanced state of materials and energy upon plant start-up, and a vapor cycle of operation fluids are symbolized and displayed on the display screen of the device. Then, the display of the plant information suitable to the information processing for a man to dissolve problems is provided. Accordingly, a mechanism for analyzing a purpose of the plant is made more definite, thereby enabling to prevent an erroneous judgement of an operator and occurrence of plant troubles. In addition, a simular effect can also be expected when the theories and rules with respect to the flow and the balanced state of materials and energy and thermohydrodynamic behavior of the operation fluids in a state of after-heat removing operation during shutdown of the plant are symbolized and displayed. (I.S.)

  6. Testing the deGroot recall paradigm to evaluate displays for operating personnel

    International Nuclear Information System (INIS)

    Moray, N.; Jones, B.G.; Rasmussen, J.

    1991-01-01

    In this paper the authors report the results of experiments based on deGroot's work to assess the value of memory tests for measuring the quality of displays and the level of expertise of operators. Three kinds of display and people with three levels of expertise were included in the experiments. The displays were computer generated versions of traditional analog meters, traditional analog meters supplemented by a dynamic graphic representing the relation between temperature and pressure in some subsystems, and a dynamic graphic representing the underlying thermodynamics of power generation using the Rankine Cycle. The levels of expertise were represented by undergraduates with one semester of thermodynamics, graduate students of thermodynamics and nuclear engineering, and professional nuclear power plant operators. Each group watched a set of transients presented on the displays, using data generated by a high fidelity NPP training simulator, and were then asked three kinds of questions. The first measured their ability to recall the exact values of system state variables. The second measured their ability to recall what qualitative states the system had entered during the transient. The third measured their ability diagnose the nature of the transient. The results of the experiments are reported in relation to the possible use of memory tests to evaluate displays and the interaction of the quality of displays with the level of expertise of operators

  7. Emergent features and perceptual objects: re-examining fundamental principles in analogical display design.

    Science.gov (United States)

    Holt, Jerred; Bennett, Kevin B; Flach, John M

    2015-01-01

    Two sets of design principles for analogical visual displays, based on the concepts of emergent features and perceptual objects, are described. An interpretation of previous empirical findings for three displays (bar graph, polar graphic, alphanumeric) is provided from both perspectives. A fourth display (configural coordinate) was designed using principles of ecological interface design (i.e. direct perception). An experiment was conducted to evaluate performance (accuracy and latency of state identification) with these four displays. Numerous significant effects were obtained and a clear rank ordering of performance emerged (from best to worst): configural coordinate, bar graph, alphanumeric and polar graphic. These findings are consistent with principles of design based on emergent features; they are inconsistent with principles based on perceptual objects. Some limitations of the configural coordinate display are discussed and a redesign is provided. Practitioner Summary: Principles of ecological interface design, which emphasise the quality of very specific mappings between domain, display and observer constraints, are described; these principles are applicable to the design of all analogical graphical displays.

  8. Flight Deck Display Technologies for 4DT and Surface Equivalent Visual Operations

    Science.gov (United States)

    Prinzel, Lawrence J., III; Jones, Denis R.; Shelton, Kevin J.; Arthur, Jarvis J., III; Bailey, Randall E.; Allamandola, Angela S.; Foyle, David C.; Hooey, Becky L.

    2009-01-01

    NASA research is focused on flight deck display technologies that may significantly enhance situation awareness, enable new operating concepts, and reduce the potential for incidents/accidents for terminal area and surface operations. The display technologies include surface map, head-up, and head-worn displays; 4DT guidance algorithms; synthetic and enhanced vision technologies; and terminal maneuvering area traffic conflict detection and alerting systems. This work is critical to ensure that the flight deck interface technologies and the role of the human participants can support the full realization of the Next Generation Air Transportation System (NextGen) and its novel operating concepts.

  9. Color speckle in laser displays

    Science.gov (United States)

    Kuroda, Kazuo

    2015-07-01

    At the beginning of this century, lighting technology has been shifted from discharge lamps, fluorescent lamps and electric bulbs to solid-state lighting. Current solid-state lighting is based on the light emitting diodes (LED) technology, but the laser lighting technology is developing rapidly, such as, laser cinema projectors, laser TVs, laser head-up displays, laser head mounted displays, and laser headlamps for motor vehicles. One of the main issues of laser displays is the reduction of speckle noise1). For the monochromatic laser light, speckle is random interference pattern on the image plane (retina for human observer). For laser displays, RGB (red-green-blue) lasers form speckle patterns independently, which results in random distribution of chromaticity, called color speckle2).

  10. Three-dimensional Imaging, Visualization, and Display

    CERN Document Server

    Javidi, Bahram; Son, Jung-Young

    2009-01-01

    Three-Dimensional Imaging, Visualization, and Display describes recent developments, as well as the prospects and challenges facing 3D imaging, visualization, and display systems and devices. With the rapid advances in electronics, hardware, and software, 3D imaging techniques can now be implemented with commercially available components and can be used for many applications. This volume discusses the state-of-the-art in 3D display and visualization technologies, including binocular, multi-view, holographic, and image reproduction and capture techniques. It also covers 3D optical systems, 3D display instruments, 3D imaging applications, and details several attractive methods for producing 3D moving pictures. This book integrates the background material with new advances and applications in the field, and the available online supplement will include full color videos of 3D display systems. Three-Dimensional Imaging, Visualization, and Display is suitable for electrical engineers, computer scientists, optical e...

  11. Withaferin-A displays enhanced anxiolytic efficacy without tolerance ...

    African Journals Online (AJOL)

    Withaferin-A dose-dependently (10 tob40 mg/kg) displayed anxiolytic activity, as measured by an increase in open arm exploration time in the elevated plus-maze (EPM), following intraperitoneal (i.p.) administration in rats. Acute administration of withaferin-A at 40.0 mg/kg significantly (P<0.05) increased open arm ...

  12. Paint your plate: effectiveness of a point-of-purchase display.

    Science.gov (United States)

    Colapinto, Cynthia K; Malaviarachchi, Darshaka

    2009-01-01

    This study was conducted to determine consumer understanding and retention of nutrition information presented at grocery stores during the Paint Your Plate campaign via two approaches: interactive display events and brochure distribution. Data were collected at 17 grocery stores in northern Ontario. Eleven stores held interactive display events with public health staff, a display, resources, and food samples. Six stores only distributed brochures. A total of 688 participants completed a baseline questionnaire, and 432 consented to a three-month follow-up telephone call. Of these, 201 were randomly selected to participate. Participants at interactive display events were six times more likely than participants receiving brochures to identify a serving size of fruit and vegetables (odds ratio [OR]=5.88; 95% confidence interval [CI]: 4.05, 8.54) and 23 times more likely to identify the recommended number of servings of fruit and vegetables (OR=22.67; 95% CI: 14.29, 35.98). However, at follow-up, there was no significant difference between type of event and the ability to answer correctly. Interactive displays increased immediate knowledge but failed to increase retention, a finding that suggests consistent presence of the message is needed to reinforce initial understanding and retention. More emphasis should be placed on directing funding toward increasing the frequency and duration of promotional efforts.

  13. Color seamlessness in multi-projector displays using constrained gamut morphing.

    Science.gov (United States)

    Sajadi, Behzad; Lazarov, Maxim; Majumder, Aditi; Gopi, M

    2009-01-01

    Multi-projector displays show significant spatial variation in 3D color gamut due to variation in the chromaticity gamuts across the projectors, vignetting effect of each projector and also overlap across adjacent projectors. In this paper we present a new constrained gamut morphing algorithm that removes all these variations and results in true color seamlessness across tiled multiprojector displays. Our color morphing algorithm adjusts the intensities of light from each pixel of each projector precisely to achieve a smooth morphing from one projector's gamut to the other's through the overlap region. This morphing is achieved by imposing precise constraints on the perceptual difference between the gamuts of two adjacent pixels. In addition, our gamut morphing assures a C1 continuity yielding visually pleasing appearance across the entire display.We demonstrate our method successfully on a planar and a curved display using both low and high-end projectors. Our approach is completely scalable, efficient and automatic. We also demonstrate the real-time performance of our image correction algorithm on GPUs for interactive applications. To the best of our knowledge, this is the first work that presents a scalable method with a strong foundation in perception and realizes, for the first time, a truly seamless display where the number of projectors cannot be deciphered.

  14. Development of an Evaluation Method for the Design Complexity of Computer-Based Displays

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyoung Ju; Lee, Seung Woo; Kang, Hyun Gook; Seong, Poong Hyun [KAIST, Daejeon (Korea, Republic of); Park, Jin Kyun [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2011-10-15

    The importance of the design of human machine interfaces (HMIs) for human performance and the safety of process industries has long been continuously recognized for many decades. Especially, in the case of nuclear power plants (NPPs), HMIs have significant implications for the safety of the NPPs because poor HMIs can impair the decision making ability of human operators. In order to support and increase the decision making ability of human operators, advanced HMIs based on the up-to-date computer technology are provided. Human operators in advanced main control room (MCR) acquire information through video display units (VDUs) and large display panel (LDP), which is required for the operation of NPPs. These computer-based displays contain a huge amount of information and present it with a variety of formats compared to those of a conventional MCR. For example, these displays contain more display elements such as abbreviations, labels, icons, symbols, coding, etc. As computer-based displays contain more information, the complexity of advanced displays becomes greater due to less distinctiveness of each display element. A greater understanding is emerging about the effectiveness of designs of computer-based displays, including how distinctively display elements should be designed. This study covers the early phase in the development of an evaluation method for the design complexity of computer-based displays. To this end, a series of existing studies were reviewed to suggest an appropriate concept that is serviceable to unravel this problem

  15. Observation interventions as a means to manipulate collective efficacy in groups.

    Science.gov (United States)

    Bruton, Adam M; Mellalieu, Stephen D; Shearer, David A

    2014-02-01

    The purpose of this multistudy investigation was to examine observation as an intervention for the manipulation of individual collective efficacy beliefs. Study 1 compared the effects of positive, neutral, and negative video footage of practice trials from an obstacle course task on collective efficacy beliefs in assigned groups. The content of the observation intervention (i.e., positive, neutral, and negative video footage) significantly influenced the direction of change in collective efficacy (p team/sport vs. unfamiliar team/sport) on individual collective efficacy perceptions when observing positive footage of competitive basketball performance. Collective efficacy significantly increased for both the familiar and unfamiliar conditions postintervention, with the largest increase for the familiar condition (p individual perceptions of collective efficacy in group-based activities. The findings suggest that observations of any group displaying positive group characteristics are likely to increase collective efficacy beliefs; however, observation of one's own team leads to the greatest increases.

  16. Common display performance requirements for military and commercial aircraft product lines

    Science.gov (United States)

    Hoener, Steven J.; Behrens, Arthur J.; Flint, John R.; Jacobsen, Alan R.

    2001-09-01

    Obtaining high quality Active Matrix Liquid Crystal (AMLCD) glass to meet the needs of the commercial and military aerospace business is a major challenge, at best. With the demise of all domestic sources of AMLCD substrate glass, the industry is now focused on overseas sources, which are primarily producing glass for consumer electronics. Previous experience with ruggedizing commercial glass leads to the expectation that the aerospace industry can leverage off the commercial market. The problem remains, while the commercial industry is continually changing and improving its products, the commercial and military aerospace industries require stable and affordable supplies of AMLCD glass for upwards of 20 years to support production and maintenance operations. The Boeing Engineering and Supplier Management Process Councils have chartered a group of displays experts from multiple aircraft product divisions within the Boeing Company, the Displays Process Action Team (DPAT), to address this situation from an overall corporate perspective. The DPAT has formulated a set of Common Displays Performance Requirements for use across the corporate line of commercial and military aircraft products. Though focused on the AMLCD problem, the proposed common requirements are largely independent of display technology. This paper describes the strategy being pursued within the Boeing Company to address the AMLCD supply problem and details the proposed implementation process, centered on common requirements for both commercial and military aircraft displays. Highlighted in this paper are proposed common, or standard, display sizes and the other major requirements established by the DPAT, along with the rationale for these requirements.

  17. Effect of the Oculus Rift head mounted display on postural stability

    DEFF Research Database (Denmark)

    Epure, Paula; Gheorghe, Cristina; Nissen, Thomas

    2014-01-01

    board controlling a skiing game. Two tests were conducted: full-vision versus blindfolded and HMD versus monitor display. Results were that five of the six balance-impaired adults and six of the eight non-balance-impaired adults showed higher degree of postural stability while using a monitor display......This study explored how a HMD-experienced virtual environment influences physical balance of six balance-impaired adults 59-69 years-of-age, when compared to a control group of eight non-balance-impaired adults, 18-28 years-of-age. The setup included a Microsoft Kinect and a self-created balance....... Conclusions are that HMD, used in this context, leads to postural instability....

  18. Color image quality in projection displays: a case study

    Science.gov (United States)

    Strand, Monica; Hardeberg, Jon Y.; Nussbaum, Peter

    2005-01-01

    Recently the use of projection displays has increased dramatically in different applications such as digital cinema, home theatre, and business and educational presentations. Even if the color image quality of these devices has improved significantly over the years, it is still a common situation for users of projection displays that the projected colors differ significantly from the intended ones. This study presented in this paper attempts to analyze the color image quality of a large set of projection display devices, particularly investigating the variations in color reproduction. As a case study, a set of 14 projectors (LCD and DLP technology) at Gjovik University College have been tested under four different conditions: dark and light room, with and without using an ICC-profile. To find out more about the importance of the illumination conditions in a room, and the degree of improvement when using an ICC-profile, the results from the measurements was processed and analyzed. Eye-One Beamer from GretagMacbeth was used to make the profiles. The color image quality was evaluated both visually and by color difference calculations. The results from the analysis indicated large visual and colorimetric differences between the projectors. Our DLP projectors have generally smaller color gamut than LCD projectors. The color gamuts of older projectors are significantly smaller than that of newer ones. The amount of ambient light reaching the screen is of great importance for the visual impression. If too much reflections and other ambient light reaches the screen, the projected image gets pale and has low contrast. When using a profile, the differences in colors between the projectors gets smaller and the colors appears more correct. For one device, the average ΔE*ab color difference when compared to a relative white reference was reduced from 22 to 11, for another from 13 to 6. Blue colors have the largest variations among the projection displays and makes them

  19. Maxillary anterior papilla display during smiling: a clinical study of the interdental smile line.

    Science.gov (United States)

    Hochman, Mark N; Chu, Stephen J; Tarnow, Dennis P

    2012-08-01

    The purpose of this research was to quantify the visual display (presence) or lack of display (absence) of interdental papillae during maximum smiling in a patient population aged 10 to 89 years. Four hundred twenty digital single-lens reflex photographs of patients were taken and examined for the visual display of interdental papillae between the maxillary anterior teeth during maximum smiling. Three digital photographs were taken per patient from the frontal, right frontal-lateral, and left frontal-lateral views. The data set of photographs was examined by two examiners for the presence or absence of the visual display of papillae. The visual display of interdental papillae during maximum smiling occurred in 380 of the 420 patients examined in this study, equivalent to a 91% occurrence rate. Eighty-seven percent of all patients categorized as having a low gingival smile line (n = 303) were found to display the interdental papillae upon smiling. Differences were noted for individual age groups according to the decade of life as well as a trend toward decreasing papillary display with increasing age. The importance of interdental papillae display during dynamic smiling should not be left undiagnosed since it is visible in over 91% of older patients and in 87% of patients with a low gingival smile line, representing a common and important esthetic element that needs to be assessed during smile analysis of the patient.

  20. SNS online display technologies for EPICS

    International Nuclear Information System (INIS)

    Kasemir, K.U.; Chen, X.; Purcell, J.; Danilova, E.

    2012-01-01

    The ubiquitousness of web clients from personal computers to cell phones results in a growing demand for web-based access to control system data. At the Oak Ridge National Laboratory Spallation Neutron Source (SNS) we have investigated different technical approaches to provide read access to data in the Experimental Physics and Industrial Control System (EPICS) for a wide variety of web client devices. The core web technology, HTTP, is less than ideal for online control system displays. Appropriate use of Ajax, especially the Long Poll paradigm, can alleviate fundamental HTTP limitations. The SNS Status web uses basic Ajax technology to generate generic displays for a wide audience. The Dashboard uses Long Poll and more client-side Java-Script to offer more customization and faster updates for users that need specialized displays. The Web OPI uses RAP for web access to any BOY display, offering utmost flexibility because users can create their own BOY displays in CSS. These three approaches complement each other. Users can access generic status displays with zero effort, invest time in creating their fully customized displays for the Web OPI, or use the Dashboard as an intermediate solution

  1. Dyes for displays

    Science.gov (United States)

    Claussen, U.

    1984-01-01

    The improvement of contrast and visibility of LCD by two different means was undertaken. The two methods are: (1) development of fluorescent dyes to increase the visibility of fluorescent activated displays (FLAD); and (2) development of dichroic dyes to increase the contrast of displays. This work was done in close cooperation with the electronic industry, where the newly synthesized dyes were tested. The targets for the chemical synthesis were selected with the help of computer model calculations. A marketable range of dyes was developed. Since the interest of the electronic industries concerning FLAD was low, the investigations were stopped. Dichroic dyes, especially black mixtures with good light fastness, order parameter, and solubility in nematic phases were developed. The application of these dyes is restricted to indoor use because of an increase of viscosity below -10 C. Applications on a technical scale, e.g., for the automotive industry, will be possible if the displays work at temperatures down to -40 C. This problem requires a complex optimization of the dye/nematic phase system.

  2. A high-resolution and intelligent dead pixel detection scheme for an electrowetting display screen

    Science.gov (United States)

    Luo, ZhiJie; Luo, JianKun; Zhao, WenWen; Cao, Yang; Lin, WeiJie; Zhou, GuoFu

    2018-02-01

    Electrowetting display technology is realized by tuning the surface energy of a hydrophobic surface by applying a voltage based on electrowetting mechanism. With the rapid development of the electrowetting industry, how to analyze efficiently the quality of an electrowetting display screen has a very important significance. There are two kinds of dead pixels on the electrowetting display screen. One is that the oil of pixel cannot completely cover the display area. The other is that indium tin oxide semiconductor wire connecting pixel and foil was burned. In this paper, we propose a high-resolution and intelligent dead pixel detection scheme for an electrowetting display screen. First, we built an aperture ratio-capacitance model based on the electrical characteristics of electrowetting display. A field-programmable gate array is used as the integrated logic hub of the system for a highly reliable and efficient control of the circuit. Dead pixels can be detected and displayed on a PC-based 2D graphical interface in real time. The proposed dead pixel detection scheme reported in this work has promise in automating electrowetting display experiments.

  3. Flat panel planar optic display

    Energy Technology Data Exchange (ETDEWEB)

    Veligdan, J.T. [Brookhaven National Lab., Upton, NY (United States). Dept. of Advanced Technology

    1994-11-01

    A prototype 10 inch flat panel Planar Optic Display, (POD), screen has been constructed and tested. This display screen is comprised of hundreds of planar optic class sheets bonded together with a cladding layer between each sheet where each glass sheet represents a vertical line of resolution. The display is 9 inches wide by 5 inches high and approximately 1 inch thick. A 3 milliwatt HeNe laser is used as the illumination source and a vector scanning technique is employed.

  4. Meibomian Gland Dysfunction Determines the Severity of the Dry Eye Conditions in Visual Display Terminal Workers

    Science.gov (United States)

    Dong, Nuo; Yang, Fan; Lin, Zhirong; Shang, Xumin; Li, Cheng

    2014-01-01

    Objective To explore meibomian gland dysfunction (MGD) may determine the severity of dry eye conditions in visual display terminal (VDT) workers. Methodology Prospective, case-control study carried out in China.106 eyes of 53 patients (VDT work time >4 hour per day) were recruited as the Long time VDT group; 80 eyes of 40 control subjects (VDT work time ≤4 hour per day) served as the Short time VDT group. A questionnaire of Ocular Surface Disease Index (OSDI) and multiple tests were performed. Three dry eye tests: tear film breakup time (BUT), corneal fluorescein staining, Schirmer I test; and three MGD parameters: lid margin abnormality score, meibum expression assessment (meibum score), and meibomian gland dropout degree (meiboscore) using Keratograph 5 M. Principal Findings OSDI and corneal fluorescein score were significantly higher while BUT was dramatically shorter in the long time VDT group than the short time VDT group. However, the average of Schirmer tear volumes was in normal ranges in both groups. Interestingly, the three MGD parameters were significantly higher in the long time VDT group than the short time one (Peyes with Schirmer eyes with Schirmer ≥10 mm were separated from the long time VDT workers, no significant differences were found between the two subgroups in OSDI, fluorescein staining and BUT, as well as the three MGD parameters. All three MGD parameters were positively correlated with VDT working time (Pdry eye patients in long term VDT workers with higher OSDI scores whereas some of those patients presenting a normal tear volume. PMID:25144638

  5. Performance of NCAP projection displays

    Science.gov (United States)

    Jones, Philip J.; Tomita, Akira; Wartenberg, Mark

    1991-08-01

    Prototypes of projection displays based on dispersions of liquid crystal in polymer matrices are beginning to appear. The principle of operation depends on electrically switchable light scattering. They are potentially much brighter than current cathode ray tube (CRT) or twisted nematic liquid crystal (TN LC) cell based displays. Comparisons of efficacy and efficiency show this. The contrast and brightness of such displays depend on a combination of the f- number of the projection system and the scattering characteristics of the light valve. Simplified equations can be derived to show these effects. The degree of scattering of current NCAP formulations is sufficient to produce good contrast projection displays, at convenient voltages, that are around three times brighter than TN LC projectors because of the lack of polarizers in the former.

  6. Compressive multi-mode superresolution display

    KAUST Repository

    Heide, Felix

    2014-01-01

    Compressive displays are an emerging technology exploring the co-design of new optical device configurations and compressive computation. Previously, research has shown how to improve the dynamic range of displays and facilitate high-quality light field or glasses-free 3D image synthesis. In this paper, we introduce a new multi-mode compressive display architecture that supports switching between 3D and high dynamic range (HDR) modes as well as a new super-resolution mode. The proposed hardware consists of readily-available components and is driven by a novel splitting algorithm that computes the pixel states from a target high-resolution image. In effect, the display pixels present a compressed representation of the target image that is perceived as a single, high resolution image. © 2014 Optical Society of America.

  7. Nuclear image display controller

    International Nuclear Information System (INIS)

    Roth, D.A.

    1985-01-01

    In a nuclear imaging system the digitized x and y coordinates of gamma ray photon emission events address memory locations corresponding to the coordinates. The respective locations are incremented each time they are addressed so at the end of a selected time or event count period the locations contain digital values or raw data corresponding to the intensity of pixels comprising an image frame. The raw data for a frame is coupled to one input of an arithmetic logic unit (ALU) whose output is coupled to a display controller memory. The output of the controller memory is coupled to another ALU input with a feedback bus and is also coupled to a further signal processing circuit which includes means for converting processed data to analog video signals for television display. The ALU is selectively controlled to let raw image data pass through to the display controllor memory or alternately to add (or subtract) raw data for the last image frame developed to the raw data for preceding frames held in the display controller to thereby produce the visual effect on the television screen of an isotope flowing through anatomy

  8. [Current situations and problems of quality control for medical imaging display systems].

    Science.gov (United States)

    Shibutani, Takayuki; Setojima, Tsuyoshi; Ueda, Katsumi; Takada, Katsumi; Okuno, Teiichi; Onoguchi, Masahisa; Nakajima, Tadashi; Fujisawa, Ichiro

    2015-04-01

    Diagnostic imaging has been shifted rapidly from film to monitor diagnostic. Consequently, Japan medical imaging and radiological systems industries association (JIRA) have recommended methods of quality control (QC) for medical imaging display systems. However, in spite of its need by majority of people, executing rate is low. The purpose of this study was to validate the problem including check items about QC for medical imaging display systems. We performed acceptance test of medical imaging display monitors based on Japanese engineering standards of radiological apparatus (JESRA) X-0093*A-2005 to 2009, and performed constancy test based on JESRA X-0093*A-2010 from 2010 to 2012. Furthermore, we investigated the cause of trouble and repaired number. Medical imaging display monitors had 23 inappropriate monitors about visual estimation, and all these monitors were not criteria of JESRA about luminance uniformity. Max luminance was significantly lower year-by-year about measurement estimation, and the 29 monitors did not meet the criteria of JESRA about luminance deviation. Repaired number of medical imaging display monitors had 25, and the cause was failure liquid crystal panel. We suggested the problems about medical imaging display systems.

  9. On-line data display

    Science.gov (United States)

    Lang, Sherman Y. T.; Brooks, Martin; Gauthier, Marc; Wein, Marceli

    1993-05-01

    A data display system for embedded realtime systems has been developed for use as an operator's user interface and debugging tool. The motivation for development of the On-Line Data Display (ODD) have come from several sources. In particular the design reflects the needs of researchers developing an experimental mobile robot within our laboratory. A proliferation of specialized user interfaces revealed a need for a flexible communications and graphical data display system. At the same time the system had to be readily extensible for arbitrary graphical display formats which would be required for data visualization needs of the researchers. The system defines a communication protocol transmitting 'datagrams' between tasks executing on the realtime system and virtual devices displaying the data in a meaningful way on a graphical workstation. The communication protocol multiplexes logical channels on a single data stream. The current implementation consists of a server for the Harmony realtime operating system and an application written for the Macintosh computer. Flexibility requirements resulted in a highly modular server design, and a layered modular object- oriented design for the Macintosh part of the system. Users assign data types to specific channels at run time. Then devices are instantiated by the user and connected to channels to receive datagrams. The current suite of device types do not provide enough functionality for most users' specialized needs. Instead the system design allows the creation of new device types with modest programming effort. The protocol, design and use of the system are discussed.

  10. Flexible displays, rigid designs?

    DEFF Research Database (Denmark)

    Hornbæk, Kasper

    2015-01-01

    Rapid technological progress has enabled a wide range of flexible displays for computing devices, but the user experience--which we're only beginning to understand--will be the key driver for successful designs.......Rapid technological progress has enabled a wide range of flexible displays for computing devices, but the user experience--which we're only beginning to understand--will be the key driver for successful designs....

  11. Microencapsulated Electrophoretic Films for Electronic Paper Displays

    Science.gov (United States)

    Amundson, Karl

    2003-03-01

    Despite the dominance of liquid crystal displays, they do not perform some functions very well. While backlit liquid crystal displays can offer excellent color performance, they wash out in bright lighting and suffer from high power consumption. Reflective liquid crystal displays have limited brightness, making these devices challenging to read for long periods of time. Flexible liquid crystal displays are difficult to manufacture and keep stable. All of these attributes (long battery lifetime, bright reflective appearance, compatibility with flexible substrates) are traits that would be found in an ideal electronic paper display - an updateable substitute for paper that could be employed in electronic books, newspapers, and other applications. I will discuss technologies that are being developed for electronic-paper-like displays, and especially on particle-based technologies. A microencapsulated electrophoretic display technology is being developed at the E Ink corporation. This display film offers offer high brightness and an ink-on-paper appearance, compatibility with flexible substrates, and image stability that can lead to very low power consumption. I will present some of the physical and chemical challenges associated with making display films with high performance.

  12. Evaluation and significance of hyperchromatic crowded groups (HCG in liquid-based paps

    Directory of Open Access Journals (Sweden)

    Chivukula Mamatha

    2007-01-01

    Full Text Available Abstract Objective Hyperchromatic crowded groups (HCG, a term first introduced into the cytology literature by DeMay in 1995, are commonly observed in Pap tests and may rarely be associated with serious but difficult to interpret lesions. In this study, we specifically defined HCG as dark crowded cell groups with more than 15 cells which can be identified at 10× screening magnification. Methods We evaluated consecutive liquid-based (Surepath Pap tests from 601 women (age 17–74 years, mean age 29.4 yrs and observed HCG in 477 cases. In all 477 HCG cases, Pap tests were found to be satisfactory and to contain an endocervical sample. HCG were easily detectible at 10× screening magnification (size up to 400 um, mean 239.5 um and ranged from 1 to 50 (mean 19.5 per Pap slide. Results HCG predominantly represented 3-Dimensional groups of endocervical cells with some nuclear overlap (379/477 – 79%, reactive endocervical cells with relatively prominent nucleoli and some nuclear crowding (29/477 – 6%, clusters of inflammatory cells (25/477 – 5.2%, parabasal cells (22/477 – 4.6%, endometrial cells (1/477 – 0.2%. Epithelial cell abnormalities (ECA were present in only 21 of 477 cases (4.6%. 18 of 21 women with HCG-associated ECA were less than 40 years old; only 3 were =/> 40 years. HCG-associated final abnormal Pap test interpretations were as follows: ASCUS (6/21 – 28%, LSIL (12/21 – 57%, ASC-H (2/21 – 9.5%, and HSIL/CIN2-3 (3/21 – 14%. The association of HCG with ECA was statistically significant (p = 0.0174. chi-square test. In patients with ECA, biopsy results were available in 10 cases, and 4 cases of biopsy-proven CIN2/3 were detected. Among these four cases, HCG in the Pap tests, in retrospect represented the lesional high grade cells in three cases (one HSIL case and two ASC-H cases. Interestingly, none of the 124 cases without HCG were found to have an epithelial cell abnormality. Conclusion We conclude: a. HCG are observed

  13. Three-dimensional display of femoral head cartilage thickness maps from MR images

    International Nuclear Information System (INIS)

    Rubin, R.A.; Dolecki, M.; Rubash, H.E.; Thaete, F.L.; Hernden, J.H.

    1990-01-01

    This paper reports on the development of methods for three-dimensional display and analysis of the articular cartilage of the hip from MR images. Cadaveric femoral head specimens were images with three-dimensional GRASS MR imaging. Data were analyzed on a SUN workstation with original software, the ANALYZE package from Richard Robb's Biomedical Research Group at the Mayo Clinic, and SUN's Voxvu program. The articular cartilage was isolated by manually segmenting images. An original computer ray tracing method measured the cartilage thickness radially and produced movies of a rotating femoral head, displaying brightness proportional to cartilage thickness

  14. Evaluating display fidelity and interaction fidelity in a virtual reality game.

    Science.gov (United States)

    McMahan, Ryan P; Bowman, Doug A; Zielinski, David J; Brady, Rachael B

    2012-04-01

    In recent years, consumers have witnessed a technological revolution that has delivered more-realistic experiences in their own homes through high-definition, stereoscopic televisions and natural, gesture-based video game consoles. Although these experiences are more realistic, offering higher levels of fidelity, it is not clear how the increased display and interaction aspects of fidelity impact the user experience. Since immersive virtual reality (VR) allows us to achieve very high levels of fidelity, we designed and conducted a study that used a six-sided CAVE to evaluate display fidelity and interaction fidelity independently, at extremely high and low levels, for a VR first-person shooter (FPS) game. Our goal was to gain a better understanding of the effects of fidelity on the user in a complex, performance-intensive context. The results of our study indicate that both display and interaction fidelity significantly affect strategy and performance, as well as subjective judgments of presence, engagement, and usability. In particular, performance results were strongly in favor of two conditions: low-display, low-interaction fidelity (representative of traditional FPS games) and high-display, high-interaction fidelity (similar to the real world).

  15. Informatics in Radiology (infoRAD): mobile wireless DICOM server system and PDA with high-resolution display: feasibility of group work for radiologists.

    Science.gov (United States)

    Nakata, Norio; Kandatsu, Susumu; Suzuki, Naoki; Fukuda, Kunihiko

    2005-01-01

    A novel mobile system has been developed for use by radiologists in managing Digital Imaging and Communications in Medicine (DICOM) image data. The system consists of a mobile DICOM server (MDS) and personal digital assistants (PDAs), including a Linux PDA with a video graphics array (VGA) display (307,200 pixels, 3.7 inches). The MDS weighs 410 g, has a 60-GB hard disk drive and a built-in wireless local area network (LAN) access point, and supports a DICOM server (Central Test Node). The Linux-based MDS can be accessed with personal computers (PCs) and PDAs by means of a wireless or wired LAN, and client-server communications can be established at any time. DICOM images can be displayed by using any PDA or PC by means of a Web browser. Simultaneous access to the MDS is possible for multiple authenticated users. With most PDAs, image compression is necessary for complete display of DICOM images; however, the VGA screen can display a 512 x 512-pixel DICOM image almost in its entirety. This wireless system allows efficient management of heavy loads of lossless DICOM image data and will be useful for collaborative work by radiologists in education, conferences, and research.

  16. Revisiting the debate on the relationship between display rules and performance: considering the explicitness of display rules.

    Science.gov (United States)

    Christoforou, Paraskevi S; Ashforth, Blake E

    2015-01-01

    We argue that the strength with which the organization communicates expectations regarding the appropriate emotional expression toward customers (i.e., explicitness of display rules) has an inverted U-shaped relationship with service delivery behaviors, customer satisfaction, and sales performance. Further, we argue that service organizations need a particular blend of explicitness of display rules and role discretion for the purpose of optimizing sales performance. As hypothesized, findings from 2 samples of salespeople suggest that either high or low explicitness of display rules impedes service delivery behaviors and sales performance, which peaks at moderate explicitness of display rules and high role discretion. The findings also suggest that the explicitness of display rules has a positive relationship with customer satisfaction. (c) 2015 APA, all rights reserved.

  17. Formulation of electroclinic, ferroelectric and antiferroelectric liquid crystal mixtures suitable for display devices

    Science.gov (United States)

    Debnath, Asim; Goswami, Debarghya; Mandal, Pradip Kumar

    2018-04-01

    Most of the liquid crystal display (LCD) devices starting from simplest wrist watches or calculators to complex laptops or flat TV sets are based on nematics. Although a tremendous improvement in the quality of display as well as reduction of manufacturing cost has taken place over the years, there are many issues which the LC industry is trying hard to address. Ferroelectric liquid crystals (FLC) are of current interest in the LCD industry since among various other advantages FLC based displays have micro-second order switching compared to milli-second order switching in nematic based displays. To meet the market demand much effort has been made to optimize the physical parameters of FLCs, such as temperature range, spontaneous polarization (PS), helical pitch (p), switching time (τ), tilt angle (θ) and rotational viscosity (γ). Multicomponent mixtures are, therefore, formulated to optimize all the required properties for practical applications since no single FLC compound can satisfy the above requirements. To the best of our knowledge electroclinic, ferroelectric and antiferroelectric liquid crystal mixtures have been formulated first time by any Indian group which have properties suitable for FLC based display devices and at par with mixtures used in the industry.

  18. Software for Minsk-32 display station

    International Nuclear Information System (INIS)

    Belyaeva, L.M.; Gangrskaya, O.G.; Manno, I.; Fefilov, B.V.; Ehsenski, J.

    1976-01-01

    The mathematical provision is described of the Minsk-32 display station. Described is the application of editing program DOSE, assembler translator SLANG and program display-focal. Program DOSE permits to edit the texts with the aid of a rester display on Minsk-32 magnetic tape. The program system permits to use a disk monitor system

  19. Comparative study of the blinking time between young adult and adult video display terminal users in indoor environment.

    Science.gov (United States)

    Schaefer, Tânia Mara Cunha; Schaefer, Arthur Rubens Cunha; Abib, Fernando Cesar; José, Newton Kara

    2009-01-01

    Investigate the average blinking time in conversation and in Video Display Terminal use of young adults and adults in the presbyopic age group. A transversal analytical study in a readily accessible sample consisting of Volkswagen do Brasil - Curitiba, Paraná employees was performed. The cohort group consisted of 108 subjects divided into two age groups: Group 1, the young adult group (age range 20-39): 77 employees, mean age of 30.09 +/- 5.09; Group 2, the presbyopic adult group, (age range 40-53): 31 employees, mean age of 44.17 +/- 3. Subjects under 18 years of age, with a history of ocular disorders, contact lens wearers and computer non-users were excluded. The subjects had their faces filmed for 10 minutes in conversation and VDT reading. Student's t-test was used and the statistical significance level was 95%. The average time between blinks in Group 1 for conversation and VDT reading was 5.16 +/- 1.83 and 10.42 +/- 7.78 seconds, respectively; in Group 2. 4,9 +/- 1.49 and 10.46 +/- 5.54 seconds. In both age groups, the time between blinks in VDT reading situations was higher (pgroups were compared (p>0.05). There was an increase in the blinking time between young adults and the presbyopic group in VDT use situations when compared with reading situations. The difference in the blinking frequency between young adults and the presbyopic group in VDT use and reading situations was not statistically significant.

  20. An Investigation of Interval Management Displays

    Science.gov (United States)

    Swieringa, Kurt A.; Wilson, Sara R.; Shay, Rick

    2015-01-01

    NASA's first Air Traffic Management (ATM) Technology Demonstration (ATD-1) was created to transition the most mature ATM technologies from the laboratory to the National Airspace System. One selected technology is Interval Management (IM), which uses onboard aircraft automation to compute speeds that help the flight crew achieve and maintain precise spacing behind a preceding aircraft. Since ATD-1 focuses on a near-term environment, the ATD-1 flight demonstration prototype requires radio voice communication to issue an IM clearance. Retrofit IM displays will enable pilots to both enter information into the IM avionics and monitor IM operation. These displays could consist of an interface to enter data from an IM clearance and also an auxiliary display that presents critical information in the primary field-of-view. A human-in-the-loop experiment was conducted to examine usability and acceptability of retrofit IM displays, which flight crews found acceptable. Results also indicate the need for salient alerting when new speeds are generated and the desire to have a primary field of view display available that can display text and graphic trend indicators.

  1. Distributed rendering for multiview parallax displays

    Science.gov (United States)

    Annen, T.; Matusik, W.; Pfister, H.; Seidel, H.-P.; Zwicker, M.

    2006-02-01

    3D display technology holds great promise for the future of television, virtual reality, entertainment, and visualization. Multiview parallax displays deliver stereoscopic views without glasses to arbitrary positions within the viewing zone. These systems must include a high-performance and scalable 3D rendering subsystem in order to generate multiple views at real-time frame rates. This paper describes a distributed rendering system for large-scale multiview parallax displays built with a network of PCs, commodity graphics accelerators, multiple projectors, and multiview screens. The main challenge is to render various perspective views of the scene and assign rendering tasks effectively. In this paper we investigate two different approaches: Optical multiplexing for lenticular screens and software multiplexing for parallax-barrier displays. We describe the construction of large-scale multi-projector 3D display systems using lenticular and parallax-barrier technology. We have developed different distributed rendering algorithms using the Chromium stream-processing framework and evaluate the trade-offs and performance bottlenecks. Our results show that Chromium is well suited for interactive rendering on multiview parallax displays.

  2. Common region wins the competition between extrinsic grouping cues: Evidence from a task without explicit attention to grouping.

    Science.gov (United States)

    Montoro, Pedro R; Villalba-García, Cristina; Luna, Dolores; Hinojosa, José A

    2017-12-01

    The competition between perceptual grouping factors is a relatively ignored topic, especially in the case of extrinsic grouping cues (e.g., common region or connectedness). Recent studies have examined the integration of extrinsic cues using tasks that induce selective attention to groups based on different grouping cues. However, this procedure could generate alternative strategies for task performance, which are non-related to the perceptual grouping operations. In the current work, we used an indirect task, i.e. repetition discrimination task, without explicit attention to grouping cues to further examine the rules that govern dominance between competing extrinsic grouping factors. This procedure allowed us to obtain an unbiased measure of the competition between common region and connectedness cues acting within the same display. The results corroborate previous data showing that grouping by common region dominated the perceived organization of the display, even though the phenomenological strength of the grouping cues was equated for each participant by means of a preliminary scaling task. Our results highlight the relevance of using indirect tasks as an essential tool for the systematic study of the integration of extrinsic grouping cues.

  3. Spielräume schulischer Displays

    Directory of Open Access Journals (Sweden)

    Antje Lehn

    2014-03-01

    Full Text Available Antje Lehn zeigt in ihrem Beitrag, wie durch einen erweiterten Display-Begriff in der Schulklasse durch konkrete Projekte Frontalunterricht unterwandert und das Klassenzimmer zu einem ergebnisoffenen Handlungsraum umgestaltet werden kann. Auch Decken, Spiegel, Tische und Spinde sind Displays ...

  4. Significance of β-tubulin Expression in Breast Premalignant Lesions and Carcinomas

    Institute of Scientific and Technical Information of China (English)

    Yuxia Gao; Yun Niu; Xiumin Ding; Yong Yu

    2008-01-01

    OBJECTIVE To explore the expression of β-tubulin in premalignant lesions and carcinomas of the breast, and to observe the relationship of its expression with breast cancer pathological features.METHODS The expression of β-tubulin was detected immunohistochemically in 50 specimens of premalignant lesions of the breast (ADH and Peri-PM with ADH), 50 specimens of breast in situ ductal carcinomas (DCIS), and 50 specimens of invasive ductal carcinomas (IDC). Thirty specimens of normal breast tissues served as a control group.RESULTS Immunohistochemical analysis showed that: the differences among the 4 groups (normal breast tissues, breast premalignant lesions, DCIS and IDC, P < 0.05) were significant,and there were also statistically significant differences between any 2 groups (P < 0.05) except for the β-tubulin positive expression comparing DCIS versus IDC (P > 0.05). In addition, β-tubulin was expressed at a higher level in Peri-PM with ADH compared to ADH (P < 0.05). Following the degree of breast epithelial hyperplasia involved, and its development into carcinoma, the β-tubulin positive expression displayed an elevating tendency.We also found a significant positive relationship of β-tubulin expression with lymph node metastasis (P < 0.05), but no significant correlation with histological grading and nuclear grade.CONCLUSION Centrosome defects may be an early event in the development of breast cancer and they can also promote tumor progression. Studies of aberrations of centrosomal proteins provide a new way to explore the mechanism of breast tumorigenesis.

  5. Performance evaluation of a kinesthetic-tactual display

    Science.gov (United States)

    Jagacinski, R. J.; Flach, J. M.; Gilson, R. D.; Dunn, R. S.

    1982-01-01

    Simulator studies demonstrated the feasibility of using kinesthetic-tactual (KT) displays for providing collective and cyclic command information, and suggested that KT displays may increase pilot workload capability. A dual-axis laboratory tracking task suggested that beyond reduction in visual scanning, there may be additional sensory or cognitive benefits to the use of multiple sensory modalities. Single-axis laboratory tracking tasks revealed performance with a quickened KT display to be equivalent to performance with a quickened visual display for a low frequency sum-of-sinewaves input. In contrast, an unquickened KT display was inferior to an unquickened visual display. Full scale simulator studies and/or inflight testing are recommended to determine the generality of these results.

  6. Effect of display size on visual attention.

    Science.gov (United States)

    Chen, I-Ping; Liao, Chia-Ning; Yeh, Shih-Hao

    2011-06-01

    Attention plays an important role in the design of human-machine interfaces. However, current knowledge about attention is largely based on data obtained when using devices of moderate display size. With advancement in display technology comes the need for understanding attention behavior over a wider range of viewing sizes. The effect of display size on test participants' visual search performance was studied. The participants (N = 12) performed two types of visual search tasks, that is, parallel and serial search, under three display-size conditions (16 degrees, 32 degrees, and 60 degrees). Serial, but not parallel, search was affected by display size. In the serial task, mean reaction time for detecting a target increased with the display size.

  7. Exploring interaction with 3D volumetric displays

    Science.gov (United States)

    Grossman, Tovi; Wigdor, Daniel; Balakrishnan, Ravin

    2005-03-01

    Volumetric displays generate true volumetric 3D images by actually illuminating points in 3D space. As a result, viewing their contents is similar to viewing physical objects in the real world. These displays provide a 360 degree field of view, and do not require the user to wear hardware such as shutter glasses or head-trackers. These properties make them a promising alternative to traditional display systems for viewing imagery in 3D. Because these displays have only recently been made available commercially (e.g., www.actuality-systems.com), their current use tends to be limited to non-interactive output-only display devices. To take full advantage of the unique features of these displays, however, it would be desirable if the 3D data being displayed could be directly interacted with and manipulated. We investigate interaction techniques for volumetric display interfaces, through the development of an interactive 3D geometric model building application. While this application area itself presents many interesting challenges, our focus is on the interaction techniques that are likely generalizable to interactive applications for other domains. We explore a very direct style of interaction where the user interacts with the virtual data using direct finger manipulations on and around the enclosure surrounding the displayed 3D volumetric image.

  8. Volume scanning three-dimensional display with an inclined two-dimensional display and a mirror scanner

    Science.gov (United States)

    Miyazaki, Daisuke; Kawanishi, Tsuyoshi; Nishimura, Yasuhiro; Matsushita, Kenji

    2001-11-01

    A new three-dimensional display system based on a volume-scanning method is demonstrated. To form a three-dimensional real image, an inclined two-dimensional image is rapidly moved with a mirror scanner while the cross-section patterns of a three-dimensional object are displayed sequentially. A vector-scan CRT display unit is used to obtain a high-resolution image. An optical scanning system is constructed with concave mirrors and a galvanometer mirror. It is confirmed that three-dimensional images, formed by the experimental system, satisfy all the criteria for human stereoscopic vision.

  9. Improvements to the annunciation and display systems at Gentilly 2 NGS - An integrated approach

    Energy Technology Data Exchange (ETDEWEB)

    Dufresne, R; Desaulniers, M [Central Nucleaire Gentilly, PQ (Canada)

    1997-09-01

    Since 1990, Gentilly 2 Nuclear Generating Station has revised its overall strategy during upsets and abnormal events and has also completely revised its Emergency Operating Procedures (EOP), its abnormal General Operating Procedures (GOP) and is near completing the revision of its Operating Manuals (OM). This strategy, these new EOPs, abnormal GOPs and the abnormal OMs were validated on our full scale simulator when applicable by a multidisciplinary team composed of authorized staff, technical and safety specialists and also candidates in training for authorization. We have identified significant weakness in the annunciation and display systems impairing the management of these events. To benefit from CANDU Owner`s Group (COG) expertise, we met in some occasions the CRNL`s research team on CAMLS project (CANDU Annunciation Message List System). In order to have more immediate benefits, we chose to improve the actual annunciation and display systems using, in some cases, ideas and/or principles used in the prototype CAMLS. After a brief history, we will present the global approach used at Gentilly 2 for upset and event management and, we will therefore describe in more detail each of the improvements on annunciation and display systems which contributed to reinforce this global approach. Hereafter are some of these improvements: prioritization via color coding of window alarms, re-prioritization (major/minor) of all CRT alarms, coalescence of multi-channel analog and contact CRT alarms, increase in the amount of trends and bar charts for upset management, special alarm summary functions (contextual) for startup after a trip. We did also identify certain needs which are not yet fulfilled with the actual improved system. Finally we will describe some other proposed improvements to the annunciation and display systems that we foresee in the near future. (author). 3 refs, figs.

  10. Improvements to the annunciation and display systems at Gentilly 2 NGS - An integrated approach

    International Nuclear Information System (INIS)

    Dufresne, R.; Desaulniers, M.

    1997-01-01

    Since 1990, Gentilly 2 Nuclear Generating Station has revised its overall strategy during upsets and abnormal events and has also completely revised its Emergency Operating Procedures (EOP), its abnormal General Operating Procedures (GOP) and is near completing the revision of its Operating Manuals (OM). This strategy, these new EOPs, abnormal GOPs and the abnormal OMs were validated on our full scale simulator when applicable by a multidisciplinary team composed of authorized staff, technical and safety specialists and also candidates in training for authorization. We have identified significant weakness in the annunciation and display systems impairing the management of these events. To benefit from CANDU Owner's Group (COG) expertise, we met in some occasions the CRNL's research team on CAMLS project (CANDU Annunciation Message List System). In order to have more immediate benefits, we chose to improve the actual annunciation and display systems using, in some cases, ideas and/or principles used in the prototype CAMLS. After a brief history, we will present the global approach used at Gentilly 2 for upset and event management and, we will therefore describe in more detail each of the improvements on annunciation and display systems which contributed to reinforce this global approach. Hereafter are some of these improvements: prioritization via color coding of window alarms, re-prioritization (major/minor) of all CRT alarms, coalescence of multi-channel analog and contact CRT alarms, increase in the amount of trends and bar charts for upset management, special alarm summary functions (contextual) for startup after a trip. We did also identify certain needs which are not yet fulfilled with the actual improved system. Finally we will describe some other proposed improvements to the annunciation and display systems that we foresee in the near future. (author). 3 refs, figs

  11. Refreshing Refreshable Braille Displays.

    Science.gov (United States)

    Russomanno, Alexander; O'Modhrain, Sile; Gillespie, R Brent; Rodger, Matthew W M

    2015-01-01

    The increased access to books afforded to blind people via e-publishing has given them long-sought independence for both recreational and educational reading. In most cases, blind readers access materials using speech output. For some content such as highly technical texts, music, and graphics, speech is not an appropriate access modality as it does not promote deep understanding. Therefore blind braille readers often prefer electronic braille displays. But, these are prohibitively expensive. The search is on, therefore, for a low-cost refreshable display that would go beyond current technologies and deliver graphical content as well as text. And many solutions have been proposed, some of which reduce costs by restricting the number of characters that can be displayed, even down to a single braille cell. In this paper, we demonstrate that restricting tactile cues during braille reading leads to poorer performance in a letter recognition task. In particular, we show that lack of sliding contact between the fingertip and the braille reading surface results in more errors and that the number of errors increases as a function of presentation speed. These findings suggest that single cell displays which do not incorporate sliding contact are likely to be less effective for braille reading.

  12. Recent advances in head-mounted light field displays for virtual and augmented reality (Conference Presentation)

    Science.gov (United States)

    Hua, Hong

    2017-02-01

    Head-mounted light field displays render a true 3D scene by sampling either the projections of the 3D scene at different depths or the directions of the light rays apparently emitted by the 3D scene and viewed from different eye positions. They are capable of rendering correct or nearly correct focus cues and addressing the very well-known vergence-accommodation mismatch problem in conventional virtual and augmented reality displays. In this talk, I will focus on reviewing recent advancements of head-mounted light field displays for VR and AR applications. I will demonstrate examples of HMD systems developed in my group.

  13. Soccer Offside Judgments in Laypersons with Different Types of Static Displays.

    Directory of Open Access Journals (Sweden)

    Peter Wühr

    Full Text Available Four experiments investigated offside decisions in laypersons with different types of static displays. Previous research neglected this group although the majority of assistant referees in soccer games at the amateur level are laypersons. The aims of our research were (a to investigate the spatial resolution in laypersons' perception of offside situations, (b to search for biases in laypersons' offside judgments, and (c to develop useful displays for future research. The displays showed the moment when a midfielder passes the ball to a forward moving in the vicinity of a defender. We varied the spatial location of the forward around the defender in eleven steps and participants made their offside decision by pressing a key. Across experiments, displays varied in abstractness (simple shapes, clipart figures, photographs. There were two major findings. Firstly, both accuracy and speed of offside judgments deteriorated when the spatial distance between forward and defender decreased, approaching guessing rate at the smallest distances. Secondly, participants showed a consistent bias in favor of the non-offside response, in contrast to most studies on professional assistant referees. In sum, the results highlight the limited spatial resolution of the visual system and underscore the role of response bias in offside-judgment tasks.

  14. Gamma camera display system

    International Nuclear Information System (INIS)

    Stout, K.J.

    1976-01-01

    A gamma camera having an array of photomultipliers coupled via pulse shaping circuitry and a resistor weighting circuit to a display for forming an image of a radioactive subject is described. A linearizing circuit is coupled to the weighting circuit, the linearizing circuit including a nonlinear feedback circuit with diode coupling to the weighting circuit for linearizing the correspondence between points of the display and points of the subject. 4 Claims, 5 Drawing Figures

  15. Software for graphic display systems

    International Nuclear Information System (INIS)

    Karlov, A.A.

    1978-01-01

    In this paper some aspects of graphic display systems are discussed. The design of a display subroutine library is described, with an example, and graphic dialogue software is considered primarily from the point of view of the programmer who uses a high-level language. (Auth.)

  16. Information Display: Considerations for Designing Modern Computer-Based Display Systems

    International Nuclear Information System (INIS)

    O'Hara, J.; Pirus, D.; Beltracchi, L.

    2003-01-01

    OAK- B135 To help nuclear utilities and suppliers design and implement plant information management systems and displays that provide accurate and timely information and require minimal navigation and interface management

  17. Tobacco point-of-sale displays in England: a snapshot survey of current practices.

    Science.gov (United States)

    Rooke, Catriona; Cheeseman, Hazel; Dockrell, Martin; Millward, Deborah; Sandford, Amanda

    2010-08-01

    Tobacco displays at the point of sale (PoS) are an important means for the tobacco industry to communicate with consumers. With regulations prohibiting PoS displays recently having come into force in Ireland, passed into law in England, Wales and Northern Ireland and some Australian states, and being considered in New Zealand, Finland and Brazil, this is an increasingly important issue. This study explores the nature of displays, the extent to which they are tobacco industry funded, and the relation between the tobacco companies and retailers. Three areas were chosen to gain a snapshot of PoS displays in England. Over 100 retailers were visited, with interviews taking place on site. Information was gathered on the type and size of tobacco display, who was paying for the display, requirements and incentives, and visits by industry representatives. The majority of retailers had gantries provided by tobacco companies. A minority of these were fitted with automated dispensers called retail vending machines. Attractive lighting and colour were often used to highlight particular products. Most retailers were being visited by industry representatives who checked displays. Some retailers also reported incentives offered to them for displaying products. The results suggest that the tobacco industry presence and control in the retail environment is significant. Tobacco companies overwhelmingly provided tobacco gantries in the shops surveyed and influenced displays through a combination of requirements and incentives. The extensive involvement of tobacco companies in providing and monitoring retail displays suggests the importance of implementing policies to end this form of advertising.

  18. Self-pollination rate and floral-display size in Asclepias syriaca (Common Milkweed) with regard to floral-visitor taxa.

    Science.gov (United States)

    Howard, Aaron F; Barrows, Edward M

    2014-06-23

    Animals fertilize thousands of angiosperm species whose floral-display sizes can significantly influence pollinator behavior and plant reproductive success. Many studies have measured the interactions among pollinator behavior, floral-display size, and plant reproductive success, but few studies have been able to separate the effects of pollinator behavior and post-pollination processes on angiosperm sexual reproduction. In this study, we utilized the highly self-incompatible pollinium-pollination system of Asclepias syriaca (Common Milkweed) to quantify how insect visitors influenced male reproductive success measured as pollen removal, female reproductive success measured as pollen deposition, and self-pollination rate. We also determined how floral-display size impacts both visitor behavior and self-pollination rate. Four insect taxonomic orders visited A. syriaca: Coleoptera, Diptera, Hymenoptera, and Lepidoptera. We focused on three groups of visitor taxa within two orders (Hymenoptera and Lepidoptera) with sample sizes large enough for quantitative analysis: Apis mellifera (Western Honey Bee), Bombus spp. (bumble bees) and lepidopterans (butterflies and moths). Qualitatively, lepidopterans had the highest pollinator importance values, but the large variability in the lepidopteran data precluded meaningful interpretation of much of their behavior. The introduced A. mellifera was the most effective and most important diurnal pollinator with regard to both pollen removal and pollen deposition. However, when considering the self-incompatibility of A. syriaca, A. mellifera was not the most important pollinator because of its high self-pollination rate as compared to Bombus spp. Additionally, the rate of self-pollination increased more rapidly with the number of flowers per inflorescence in A. mellifera than in the native Bombus spp. Apis mellifera's high rate of self-pollination may have significant negative effects on both male and female reproductive successes

  19. A Fluid Membrane-Based Soluble Ligand Display System for Live CellAssays

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Jwa-Min; Nair, Pradeep N.; Neve, Richard M.; Gray, Joe W.; Groves, Jay T.

    2005-10-14

    Cell communication modulates numerous biological processes including proliferation, apoptosis, motility, invasion and differentiation. Correspondingly, there has been significant interest in the development of surface display strategies for the presentation of signaling molecules to living cells. This effort has primarily focused on naturally surface-bound ligands, such as extracellular matrix components and cell membranes. Soluble ligands (e.g. growth factors and cytokines) play an important role in intercellular communications, and their display in a surface-bound format would be of great utility in the design of array-based live cell assays. Recently, several cell microarray systems that display cDNA, RNAi, or small molecules in a surface array format were proven to be useful in accelerating high-throughput functional genetic studies and screening therapeutic agents. These surface display methods provide a flexible platform for the systematic, combinatorial investigation of genes and small molecules affecting cellular processes and phenotypes of interest. In an analogous sense, it would be an important advance if one could display soluble signaling ligands in a surface assay format that allows for systematic, patterned presentation of soluble ligands to live cells. Such a technique would make it possible to examine cellular phenotypes of interest in a parallel format with soluble signaling ligands as one of the display parameters. Herein we report a ligand-modified fluid supported lipid bilayer (SLB) assay system that can be used to functionally display soluble ligands to cells in situ (Figure 1A). By displaying soluble ligands on a SLB surface, both solution behavior (the ability to become locally enriched by reaction-diffusion processes) and solid behavior (the ability to control the spatial location of the ligands in an open system) could be combined. The method reported herein benefits from the naturally fluid state of the supported membrane, which allows

  20. Modeling the leakage of LCD displays with local backlight for quality assessment

    DEFF Research Database (Denmark)

    Mantel, Claire; Korhonen, Jari; Pedersen, Jesper M.

    2014-01-01

    The recent technique of local backlight dimming has a significant impact on the quality of images displayed with a LCD screen with LED local dimming. Therefore it represents a necessary step in the quality assessment chain, independently from the other processes applied to images. This paper...... investigates the modeling of one of the major spatial artifacts produced by local dimming: leakage. Leakage appears in dark areas when the backlight level is too high for LC cells to block sufficiently and the final displayed brightness is higher than it should. A subjective quality experiment was run...... on videos displayed on LCD TV with local backlight dimming viewed from a 0° and 15° angles. The subjective results are then compared objective data using different leakage models: constant over the whole display or horizontally varying and three leakage factor (no leakage, measured at 0° and 15...

  1. Cinnamic acid amides from Tribulus terrestris displaying uncompetitive α-glucosidase inhibition.

    Science.gov (United States)

    Song, Yeong Hun; Kim, Dae Wook; Curtis-Long, Marcus J; Park, Chanin; Son, Minky; Kim, Jeong Yoon; Yuk, Heung Joo; Lee, Keun Woo; Park, Ki Hun

    2016-05-23

    The α-glucosidase inhibitory potential of Tribulus terrestris extracts has been reported but as yet the active ingredients are unknown. This study attempted to isolate the responsible metabolites and elucidate their inhibition mechanism of α-glucosidase. By fractionating T. terristris extracts, three cinnamic acid amide derivatives (1-3) were ascertained to be active components against α-glucosidase. The lead structure, N-trans-coumaroyltyramine 1, showed significant inhibition of α-glucosidase (IC50 = 0.42 μM). Moreover, all active compounds displayed uncompetitive inhibition mechanisms that have rarely been reported for α-glucosidase inhibitors. This kinetic behavior was fully demonstrated by showing a decrease of both Km and Vmax, and Kik/Kiv ratio ranging between 1.029 and 1.053. We progressed to study how chemical modifications to the lead structure 1 may impact inhibition. An α, β-unsaturation carbonyl group and hydroxyl group in A-ring of cinnamic acid amide emerged to be critical functionalities for α-glucosidase inhibition. The molecular modeling study revealed that the inhibitory activities are tightly related to π-π interaction as well as hydrogen bond interaction between enzyme and inhibitors. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  2. Do female cancer patients display better survival rates compared with males? Analysis of the Korean National Registry data, 2005-2009.

    Directory of Open Access Journals (Sweden)

    Kyu-Won Jung

    Full Text Available BACKGROUND: Sex differences have been reported in the prognosis of certain cancers. In this study, we investigated whether Korean females display better survival rates compared with male patients for solid tumor sites. METHODS: We analyzed data from the Korean National Cancer Incidence Database from 599,288 adult patients diagnosed with solid cancers between 2005 and 2009. Patients were followed until December 2010. We applied a relative excess risk (RER model adjusting for year of follow-up, age at diagnosis, and stage at diagnosis. RESULTS: For all solid cancer sites combined, women displayed an 11% lower risk of death compared to men (RER 0.89; 95% CI 0.88-0.90 after adjusting for year of follow-up, age, stage, and case mix. Women showed significantly lower RERs for the following sites: head/neck, esophagus, small intestine, liver, nasal cavities, lung, bone/cartilages, melanoma of skin, soft tissue, brain and CNS, and thyroid. In contrast, women displayed a poorer prognosis than did men for colorectal, laryngeal, kidney and bladder cancer. However, the survival gaps between men and women narrowed by increase in age; female patients over 75 years of age displayed a 3% higher RER of death compared with males in this age group. CONCLUSIONS: Female cancer patients display an improved survival for the majority of solid tumor sites, even after adjustment for age and stage. Age at diagnosis was the major contributor to the women's survival advantage.

  3. Prognostic significance of anaplasia and angiogenesis in childhood medulloblastoma: a pediatric oncology group study.

    Science.gov (United States)

    Ozer, Erdener; Sarialioglu, Faik; Cetingoz, Riza; Yüceer, Nurullah; Cakmakci, Handan; Ozkal, Sermin; Olgun, Nur; Uysal, Kamer; Corapcioglu, Funda; Canda, Serefettin

    2004-01-01

    The purpose of this study was to investigate whether quantitative assessment of cytologic anaplasia and angiogenesis may predict the clinical prognosis in medulloblastoma and stratify the patients to avoid both undertreatment and overtreatment. Medulloblastomas from 23 patients belonging to the Pediatric Oncology Group were evaluated with respect to some prognostic variables, including histologic assessment of nodularity and desmoplasia, grading of anaplasia, measurement of nuclear size, mitotic cell count, quantification of angiogenesis, including vascular surface density (VSD) and microvessel number (NVES), and immunohistochemical scoring of vascular endothelial growth factor (VEGF) expression. Univariate and multivariate analyses for prognostic indicators for survival were performed. Univariate analysis revealed that extensive nodularity was a significant favorable prognostic factor, whereas the presence of anaplasia, increased nuclear size, mitotic rate, VSD, and NVES were significant unfavorable prognostic factors. Using multivariate analysis, increased nuclear size was found to be an independent unfavorable prognostic factor for survival. Neither the presence of desmoplasia nor VEGF expression was significantly related to patient survival. Although care must be taken not to overstate the importance of the results of this single-institution preliminary report, pathologic grading of medulloblastomas with respect to grading of anaplasia and quantification of nodularity, nuclear size, and microvessel profiles may be clinically useful for the treatment of medulloblastomas. Further validation of the independent prognostic significance of nuclear size in stratifying patients is required.

  4. Refreshable Braille displays using EAP actuators

    Science.gov (United States)

    Bar-Cohen, Yoseph

    2010-04-01

    Refreshable Braille can help visually impaired persons benefit from the growing advances in computer technology. The development of such displays in a full screen form is a great challenge due to the need to pack many actuators in small area without interferences. In recent years, various displays using actuators such as piezoelectric stacks have become available in commercial form but most of them are limited to one line Braille code. Researchers in the field of electroactive polymers (EAP) investigated methods of using these materials to form full screen displays. This manuscript reviews the state of the art of producing refreshable Braille displays using EAP-based actuators.

  5. Refreshable Braille Displays Using EAP Actuators

    Science.gov (United States)

    Bar-Cohen, Yoseph

    2010-01-01

    Refreshable Braille can help visually impaired persons benefit from the growing advances in computer technology. The development of such displays in a full screen form is a great challenge due to the need to pack many actuators in small area without interferences. In recent years, various displays using actuators such as piezoelectric stacks have become available in commercial form but most of them are limited to one line Braille code. Researchers in the field of electroactive polymers (EAP) investigated methods of using these materials to form full screen displays. This manuscript reviews the state of the art of producing refreshable Braille displays using EAP-based actuators..

  6. LCD displays performance comparison by MTF measurement using the white noise stimulus method

    Science.gov (United States)

    Mitjà, Carles; Escofet, Jaume

    2011-01-01

    The amount of images produced to be viewed as soft copies on output displays are significantly increasing. This growing occurs at the expense of the images targeted to hard copy versions on paper or any other physical support. Even in the case of high quality hard copy production, people working in professional imaging uses different displays in selecting, editing, processing and showing images, from laptop screen to specialized high end displays. Then, the quality performance of these devices is crucial in the chain of decisions to be taken in image production. Metrics of this quality performance can help in the equipment acquisition. Different metrics and methods have been described to determine the quality performance of CRT and LCD computer displays in clinical area. One of most important metrics in this field is the device spatial frequency response obtained measuring the modulation transfer function (MTF). This work presents a comparison between the MTF of three different LCD displays, Apple MacBook Pro 15", Apple LED Cinema Display 24" and Apple iPhone4, measured by the white noise stimulus method, over vertical and horizontal directions. Additionally, different displays show particular pixels structure pattern. In order to identify this pixel structure, a set of high magnification images is taken from each display to be related with the respective vertical and horizontal MTF.

  7. System Would Generate Virtual Heads-Up Display

    Science.gov (United States)

    Lambert, James L.

    1994-01-01

    Proposed helmet-mounted electronic display system superimposes full-color alphanumerical and/or graphical information onto observer's visual field. Displayed information projected directly onto observer's retinas, giving observer illusion of full-size computer display in foreground or background. Display stereoscopic, holographic, or in form of virtual image. Used by pilots to view navigational information while looking outside or at instruments, by security officers to view information about critical facilities while looking at visitors, or possibly even stock-exchange facilities to view desktop monitors and overhead displays simultaneously. System includes acousto-optical tunable filter (AOTF), which acts as both spectral filter and spatial light modulator.

  8. Manufacturing considerations for AMLCD cockpit displays

    Science.gov (United States)

    Luo, Fang-Chen

    1995-06-01

    AMLCD cockpit displays need to meet more stringent requirements compared with AMLCD commercial displays in areas such as environmental conditions, optical performance and device reliability. Special considerations are required for the manufacturing of AMLCD cockpit displays in each process step to address these issues. Some examples are: UV stable polarizers, wide-temperature LC material, strong LC glue seal, ESS test system, gray scale voltage EEPROM, etc.

  9. Google Glass Glare: disability glare produced by a head-mounted visual display.

    Science.gov (United States)

    Longley, Chris; Whitaker, David

    2016-03-01

    Head mounted displays are a type of wearable technology - a market that is projected to expand rapidly over the coming years. Probably the most well known example is the device Google Glass (or 'Glass'). Here we investigate the extent to which the device display can interfere with normal visual function by producing monocular disability glare. Contrast sensitivity was measured in two normally sighted participants, 32 and 52 years of age. Data were recorded for the right eye, the left eye and then again in a binocular condition. Measurements were taken both with and without the Glass in place, across a range of stimulus luminance levels using a two-alternative forced-choice methodology. The device produced a significant reduction in contrast sensitivity in the right eye (>0.5 log units). The level of disability glare increased as stimulus luminance was reduced in a manner consistent with intraocular light scatter, resulting in a veiling retinal illuminance. Sensitivity in the left eye was unaffected. A significant reduction in binocular contrast sensitivity occurred at lower luminance levels due to a loss of binocular summation, although binocular sensitivity was not found to fall below the sensitivity of the better monocular level (binocular inhibition). Head mounted displays such as Google Glass have the potential to cause significant disability glare in the eye exposed to the visual display, particularly under conditions of low luminance. They can also cause a more modest binocular reduction in sensitivity by eliminating the benefits of binocular summation. © 2015 The Authors Ophthalmic & Physiological Optics © 2015 The College of Optometrists.

  10. Designing low cost LED display for the billboard

    Science.gov (United States)

    Hong, Yi-Jian; Uang, Chii-Maw; Wang, Ping-Chieh; Ho, Zu-Sheng

    2011-10-01

    With quickly advance of the computer, microelectronics and photonics technologies, LED display panel becomes a new electronic advertising media. It can be used to show any information whatever characters or graphics. Most LED display panels are built of many Light-Emitting Diodes arranged in a matrix form. The display has many advantages such as low power, low cost, long life and high definition. Because the display panel is asked to show rich color, the LED display panel's driving system becomes very complex. The design methodology of LED display panel's driver becomes more and more important to meet the market requirements. Cost is always the most important issue in public market domain. In this paper, we report a design methodology of LED display panel's driver based on the microprocessor control unit (MCU) system and LED display controller IC, HT1632C, to control three colors, RGB, color LED display panel and the modular panel size is 24*16 in matrix form. The HT1632C is a memory mapping LED display controller, it can be used on many applications, such as digital clock, thermometer, counter, voltmeter or other instrumentation readouts. Three pieces of HT1632C are used to drive a 24*16 RGB LED display panel, in our design case. Each HT163C chip is used to control one of the R, G and B color. As the drive mode is driven in DC mode, the RGB display panel can create and totally of seven colors under the control of MCU. The MCU generates the control signal to drive HT1632C. In this study, the software design methodology is adopted with dynamic display principle. When the scan frequency is 60Hz, LED display panel will get the clear picture and be able to display seven colors.

  11. Measuring emotional and cognitive empathy using dynamic, naturalistic, and spontaneous emotion displays.

    Science.gov (United States)

    Buck, Ross; Powers, Stacie R; Hull, Kyle S

    2017-10-01

    Most measures of nonverbal receiving ability use posed expressions as stimuli. As empathy measures, such stimuli lack ecological validity, as the participant is not actually experiencing emotion. An alternative approach uses natural and dynamic displays of spontaneous expressions. The Communication of Affect Receiving Ability Test (CARAT) uses as stimuli spontaneous facial expressions and gestures filmed by an unobtrusive camera of solitary participants responding to emotional images. This article reports the development and initial validation of the CARAT-Spontaneous, Posed, Regulated (CARAT-SPR), which measures both abilities to detect emotion from spontaneous displays (emotion communication accuracy) and to differentiate spontaneous, posed, and regulated displays (expression categorization ability). Although spontaneous displays are natural responses to emotional images, posed displays involve asking the sender to display "as if" responding to a particular sort of image when no image is in fact present (simulation), while Regulated displays involve asking the sender to display "as if" responding to a particular sort of image when an image of opposite valence is in fact present (masking). Expression categorization ability involves judging deception-simulation and masking-and conceptually involves a kind of perspective-taking or cognitive empathy. Emotion communication using spontaneous clips achieved a high level of accuracy and was strongly correlated with ratings of sender expressivity. Expression categorization ability was not significantly correlated with expressivity ratings and was modestly negatively correlated with emotion communication accuracy. In a brief version of the CARAT-SPR, women showed evidence of greater emotion signal detection, whereas men reported greater confidence in expression categorization. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  12. Lionfish predators use flared fin displays to initiate cooperative hunting.

    Science.gov (United States)

    Lönnstedt, Oona M; Ferrari, Maud C O; Chivers, Douglas P

    2014-06-01

    Despite considerable study, mystery surrounds the use of signals that initiate cooperative hunting in animals. Using a labyrinth test chamber, we examined whether a lionfish, Dendrochirus zebra, would initiate cooperative hunts with piscine partners. We found that D. zebra uses a stereotyped flared fin display to alert conspecific and heterospecific lionfish species Pterois antennata to the presence of prey. Per capita success rate was significantly higher for cooperative hunters when compared with solitary ones, with hunt responders assisting hunt initiators in cornering the prey using their large extended pectoral fins. The initiators would most often take the first strike at the group of prey, but both hunters would then alternate striking at the remaining prey. Results suggest that the cooperative communication signal may be characteristic to the lionfish family, as interspecific hunters were equally coordinated and successful as intraspecific hunters. Our findings emphasize the complexity of collaborative foraging behaviours in lionfish; the turn-taking in strikes suggests that individuals do not solely try to maximize their own hunting success: instead they equally share the resources between themselves. Communicative group hunting has enabled Pteroine fish to function as highly efficient predators. © 2014 The Author(s) Published by the Royal Society. All rights reserved.

  13. Tower Mesonetwork Climatology and Interactive Display Tool

    Science.gov (United States)

    Case, Jonathan L.; Bauman, William H., III

    2004-01-01

    Forecasters at the 45th Weather Squadron and Spaceflight Meteorology Group use data from the tower network over the Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS) to evaluate Launch Commit Criteria, and issue and verify forecasts for ground operations. Systematic biases in these parameters could adversely affect an analysis, forecast, or verification. Also, substantial geographical variations in temperature and wind speed can occur under specific wind directions. To address these concerns, the Applied Meteorology Unit (AMU) developed a climatology of temperatures and winds from the tower network, and identified the geographical variation and significant tower biases. The mesoclimate is largely driven by the complex land-water interfaces across KSC/CCAFS. Towers with close proximity to water typically had much warmer nocturnal temperatures and higher wind speeds throughout the year. The strongest nocturnal wind speeds occurred from October to March whereas the strongest mean daytime wind speeds occurred from February to May. These results of this project can be viewed by forecasters through an interactive graphical user interface developed by the AMU. The web-based interface includes graphical and map displays of mean, standard deviation, bias, and data availability for any combination of towers, variables, months, hours, and wind directions.

  14. [Application of the grayscale standard display function to general purpose liquid-crystal display monitors for clinical use].

    Science.gov (United States)

    Tanaka, Nobukazu; Naka, Kentaro; Sueoka, Masaki; Higashida, Yoshiharu; Morishita, Junji

    2010-01-20

    Interpretations of medical images have been shifting to soft-copy readings with liquid-crystal display (LCD) monitors. The display function of the medical-grade LCD monitor for soft-copy readings is recommended to calibrate the grayscale standard display function (GSDF) in accordance with the guidelines of Japan and other countries. In this study, the luminance and display function of five models of eight general purpose LCD monitors were measured to gain an understanding of their characteristics. Moreover, the display function (gamma 2.2 or gamma 1.8) of general purpose LCD monitors was converted to GSDF through the use of a look-up table, and the detectability of a simulated lung nodule in the chest x-ray image was examined. As a result, the maximum luminance, contrast ratio, and luminance uniformity of general purpose LCD monitors, except for one model of two LCD monitors, met the management grade 1 standard in the guideline JESRA X-0093-2005. In addition, the detectability of simulated lung nodule in the mediastinal space was obviously improved by converting the display function of a general purpose LCD monitor into GSDF.

  15. A history and overview of the safety parameter display system concept

    International Nuclear Information System (INIS)

    Joyce, J.P.; Lapinsky, G.W.

    1983-01-01

    Inquiries into the accident at the Three Mile Island Nuclear Power Plant Unit 2, on March 28, 1979 brought to public attention the need to improve operators' capabilities to interact with the systems under their control. Recommendations ran the full gamut of human/machine interaction, from improvements in training and procedures to improvements in control and display hardware in the control room. This presentation briefly traces the history and development of a display concept that evolved in the post-TMI era, the Safety Parameter Display System or SPDS. The SPDS is intended to function as a detection aid for control room operators, providing an integrated overview of significant plant parameters. The purpose of this report is to describe the general concept of SPDS, its history, and its current regulatory status. A review of NRC guidance documents is included, as well as a discussion of NRC requirements placed on the SPDS. The presentation concludes with an outline of the NRC staff review process for safety parameter display systems and a synopsis of the results of generic SPDS reviews performed thus far

  16. Generating Animated Displays of Spacecraft Orbits

    Science.gov (United States)

    Candey, Robert M.; Chimiak, Reine A.; Harris, Bernard T.

    2005-01-01

    Tool for Interactive Plotting, Sonification, and 3D Orbit Display (TIPSOD) is a computer program for generating interactive, animated, four-dimensional (space and time) displays of spacecraft orbits. TIPSOD utilizes the programming interface of the Satellite Situation Center Web (SSCWeb) services to communicate with the SSC logic and database by use of the open protocols of the Internet. TIPSOD is implemented in Java 3D and effects an extension of the preexisting SSCWeb two-dimensional static graphical displays of orbits. Orbits can be displayed in any or all of the following seven reference systems: true-of-date (an inertial system), J2000 (another inertial system), geographic, geomagnetic, geocentric solar ecliptic, geocentric solar magnetospheric, and solar magnetic. In addition to orbits, TIPSOD computes and displays Sibeck's magnetopause and Fairfield's bow-shock surfaces. TIPSOD can be used by the scientific community as a means of projection or interpretation. It also has potential as an educational tool.

  17. Effects of Viewing Displays from Different Distances on Human Visual System

    Directory of Open Access Journals (Sweden)

    Mohamed Z. Ramadan

    2017-11-01

    Full Text Available The current stereoscopic 3D displays have several human-factor issues including visual-fatigue symptoms such as eyestrain, headache, fatigue, nausea, and malaise. The viewing time and viewing distance are factors that considerably affect the visual fatigue associated with 3D displays. Hence, this study analyzes the effects of display type (2D vs. 3D and viewing distance on visual fatigue during a 60-min viewing session based on electroencephalogram (EEG relative beta power, and alpha/beta power ratio. In this study, twenty male participants watched four videos. The EEGs were recorded at two occipital lobes (O1 and O2 of each participant in the pre-session (3 min, post-session (3 min, and during a 60-min viewing session. The results showed that the decrease in relative beta power of the EEG and the increase in the alpha/beta ratio from the start until the end of the viewing session were significantly higher when watching the 3D display. When the viewing distance was increased from 1.95 m to 3.90 m, the visual fatigue was decreased in the case of the 3D-display, whereas the fatigue was increased in the case of the 2D-display. Moreover, there was approximately the same level of visual fatigue when watching videos in 2D or 3D from a long viewing distance (3.90 m.

  18. Change Blindness Phenomena for Virtual Reality Display Systems.

    Science.gov (United States)

    Steinicke, Frank; Bruder, Gerd; Hinrichs, Klaus; Willemsen, Pete

    2011-09-01

    In visual perception, change blindness describes the phenomenon that persons viewing a visual scene may apparently fail to detect significant changes in that scene. These phenomena have been observed in both computer-generated imagery and real-world scenes. Several studies have demonstrated that change blindness effects occur primarily during visual disruptions such as blinks or saccadic eye movements. However, until now the influence of stereoscopic vision on change blindness has not been studied thoroughly in the context of visual perception research. In this paper, we introduce change blindness techniques for stereoscopic virtual reality (VR) systems, providing the ability to substantially modify a virtual scene in a manner that is difficult for observers to perceive. We evaluate techniques for semiimmersive VR systems, i.e., a passive and active stereoscopic projection system as well as an immersive VR system, i.e., a head-mounted display, and compare the results to those of monoscopic viewing conditions. For stereoscopic viewing conditions, we found that change blindness phenomena occur with the same magnitude as in monoscopic viewing conditions. Furthermore, we have evaluated the potential of the presented techniques for allowing abrupt, and yet significant, changes of a stereoscopically displayed virtual reality environment.

  19. CLINICAL SURFACES -- Activity-Based Computing for Distributed Multi-Display Environments in Hospitals

    DEFF Research Database (Denmark)

    Bardram, Jakob Eyvind; Bunde-Pedersen, Jonathan; Doryab, Afsaneh

    2009-01-01

    A multi-display environment (MDE) is made up of co-located and networked personal and public devices that form an integrated workspace enabling co-located group work. Traditionally, MDEs have, however, mainly been designed to support a single “smart room”, and have had little sense of the tasks...

  20. IMDISP - INTERACTIVE IMAGE DISPLAY PROGRAM

    Science.gov (United States)

    Martin, M. D.

    1994-01-01

    The Interactive Image Display Program (IMDISP) is an interactive image display utility for the IBM Personal Computer (PC, XT and AT) and compatibles. Until recently, efforts to utilize small computer systems for display and analysis of scientific data have been hampered by the lack of sufficient data storage capacity to accomodate large image arrays. Most planetary images, for example, require nearly a megabyte of storage. The recent development of the "CDROM" (Compact Disk Read-Only Memory) storage technology makes possible the storage of up to 680 megabytes of data on a single 4.72-inch disk. IMDISP was developed for use with the CDROM storage system which is currently being evaluated by the Planetary Data System. The latest disks to be produced by the Planetary Data System are a set of three disks containing all of the images of Uranus acquired by the Voyager spacecraft. The images are in both compressed and uncompressed format. IMDISP can read the uncompressed images directly, but special software is provided to decompress the compressed images, which can not be processed directly. IMDISP can also display images stored on floppy or hard disks. A digital image is a picture converted to numerical form so that it can be stored and used in a computer. The image is divided into a matrix of small regions called picture elements, or pixels. The rows and columns of pixels are called "lines" and "samples", respectively. Each pixel has a numerical value, or DN (data number) value, quantifying the darkness or brightness of the image at that spot. In total, each pixel has an address (line number, sample number) and a DN value, which is all that the computer needs for processing. DISPLAY commands allow the IMDISP user to display all or part of an image at various positions on the display screen. The user may also zoom in and out from a point on the image defined by the cursor, and may pan around the image. To enable more or all of the original image to be displayed on the

  1. Design Integration of Man-Machine Interface (MMI) Display Drawings and MMI Database

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Jun; Seo, Kwang Rak; Song, Jeong Woog; Kim, Dae Ho; Han, Jung A [KEPCO Engineering and Construction Co., Deajeon (Korea, Republic of)

    2016-10-15

    The conventional Main Control Room (MCR) was designed using hardwired controllers and analog indications mounted on control boards for control and acquisition of plant information. This is compared with advanced MCR design where Flat Panel Displays (FPDs) with soft controls and mimic displays are used. The advanced design needs MMI display drawings replacing the conventional control board layout drawings and component lists. The data is linked to related object of the MMI displays. Compilation of the data into the DB is generally done manually, which tends to introduce errors and discrepancies. Also, updating and managing is difficult due to a huge number of entries in the DB and the update must closely track the changes in the associated drawing. Therefore, automating the DB update whenever a related drawing is updated would be quite beneficial. An attempt is made to develop a new method to integrate the MMIS display drawing design and the DB management. This would significantly reduce the amount of errors and improve design quality. The design integration of the MMI Display drawing and MMI DB is explained briefly but concisely in this paper. The existing method involved individually and separately inputting design data for the MMI display drawings. This caused to the potential problem of data discrepancies and errors as well as the update time lag between related drawings and the DB. This led to development of an integration of design process which automates the design data input activity.

  2. On the Question of Methodological Support of Research on Relationships of Interpersonal Significance in Kindergarten Groups

    Directory of Open Access Journals (Sweden)

    Iliyn V.A.

    2016-03-01

    Full Text Available The paper focuses on the importance of in-depth research (in particular, employing an algorithm developed by M.Yu. Kondratyev for defining integral status of an individual on child-child interpersonal relationship in kindergarten groups. Although relationships with significant adults are by all means essential for preschool children, interpersonal relation- ships on the child-child level to a great extent shape the content of the social situation of development in general. Still, when it comes to revealing status and role position of the child in the structure of interpersonal relationships within the kindergarten group, there’s the challenge of defining informal intragroup structure of power in contact community (due to the age specifics. The paper suggests how this challenge may be addressed and provides a version of the technique suitable for preschoolers that helps overcome age restrictions implied by the original technique. Also, the paper reports on the outcomes of approbation of this version which proved its heuristic nature. For instance, the outcomes show a high degree of correlation between the results of kindergarten group members ranking in accordance with their influence upon peers carried out by teachers working in these groups.

  3. Significance of ABO-Rh blood groups in response and prognosis in breast cancer patients treated with radiotherapy and chemotherapy.

    Science.gov (United States)

    Cihan, Yasemin Benderli

    2014-01-01

    To evaluate whether ABO-Rh blood groups have significance in the treatment response and prognosis in patients with non-metastatic breast cancer. We retrospectively evaluated files of 335 patients with breast cancer who were treated between 2005 and 2010. Demographic data, clinic- pathological findings, treatments employed, treatment response, and overall and disease-free survivals were reviewed. Relationships between clinic-pathological findings and blood groups were evaluated. 329 women and 6 men were included to the study. Mean age at diagnosis was 55.2 years (range: 26-86). Of the cases, 95% received chemotherapy while 70% were given radiotherapy and 60.9% adjuvant hormone therapy after surgery. Some 63.0% were A blood group, 17.6% O, 14.3% B and 5.1% AB. In addition, 82.0% of the cases were Rh-positive. Mean follow-up was 24.5 months. Median overall and progression-free survival times were 83.9 and 79.5 months, respectively. Overall and disease-free survival times were found to be higher in patients with A and O blood groups (pgroup (p=0.226). In univariate and multivariate analyses, ABO blood groups were identified as factors that had significant effects on overall and disease-survival times (p=0.011 and p=0.002). It was seen that overall and disease-free survival times were higher in breast cancer patients with A and O blood groups when compared to those with other blood groups. It was seen that A and O blood groups had good prognostic value in patients with breast cancer.

  4. MEPR versus EEPR valves in open supermarket refrigerated display cabinets

    International Nuclear Information System (INIS)

    Tahir, A.; Bansal, P.K.

    2005-01-01

    This paper presents the comparative experimental field performance of mechanical evaporator pressure regulating valves (MEPR) and electronic evaporator pressure regulating valves (EEPR) under the identical operating conditions of supermarket open multi-deck refrigerated display cabinets. The main goal of the supermarket refrigeration system design is to keep the displayed product at the required constant temperature, while minimising the cooling load to increase the overall energy efficiency of the system. Field tests have shown that the electronic evaporator pressure valve has a significant effect on improving the cabinet temperature and reducing the rate of frost formation on the evaporator coils with subsequent improvements in the air curtain strength

  5. You Be the Judge: Display.

    Science.gov (United States)

    Koeninger, Jimmy G.

    The instructional package was developed to provide the distributive education teacher-coordinator with visual materials that can be used to supplement existing textbook offerings in the area of display (visual merchandising). Designed for use with 35mm slides of retail store displays, the package allows the student to view the slides of displays…

  6. Method for control-room display design

    International Nuclear Information System (INIS)

    Montmayeul, R.

    1988-01-01

    This document describes a method for control-room displays design. It can be used either for isolated display to add to an existing system either for the design of a full system of operator aids. The method is a top-down design with steps of possible iteration. The emphasis is put on display design rather than on system design; system aspects are just mentioned. Advantages of using a method are described [fr

  7. Statistical Arbitrage Mining for Display Advertising

    OpenAIRE

    Zhang, Weinan; Wang, Jun

    2015-01-01

    We study and formulate arbitrage in display advertising. Real-Time Bidding (RTB) mimics stock spot exchanges and utilises computers to algorithmically buy display ads per impression via a real-time auction. Despite the new automation, the ad markets are still informationally inefficient due to the heavily fragmented marketplaces. Two display impressions with similar or identical effectiveness (e.g., measured by conversion or click-through rates for a targeted audience) may sell for quite diff...

  8. Tooth display and lip position during spontaneous and posed smiling in adults.

    Science.gov (United States)

    Van Der Geld, Pieter; Oosterveld, Paul; Berge, Stefaan J; Kuijpers-Jagtman, Anne M

    2008-08-01

    To analyze differences in tooth display, lip-line height, and smile width between the posed smiling record, traditionally produced for orthodontic diagnosis, and the spontaneous (Duchenne) smile of joy. The faces of 122 male participants were each filmed during spontaneous and posed smiling. Spontaneous smiles were elicited through the participants watching a comical movie. Maxillary and mandibular lip-line heights, tooth display, and smile width were measured using a digital videographic method for smile analysis. Paired sample t-tests were used to compare measurements of posed and spontaneous smiling. Maxillary lip-line heights during spontaneous smiling were significantly higher than during posed smiling. Compared to spontaneous smiling, tooth display in the (pre)molar area during posed smiling decreased by up to 30%, along with a significant reduction of smile width. During posed smiling, also mandibular lip-line heights changed and the teeth were more covered by the lower lip than during spontaneous smiling. Reduced lip-line heights, tooth display, and smile width on a posed smiling record can have implications for the diagnostics of lip-line height, smile arc, buccal corridors, and plane of occlusion. Spontaneous smiling records next to posed smiling records are therefore recommended for diagnostic purposes. Because of the dynamic nature of spontaneous smiling, it is proposed to switch to dynamic video recording of the smile.

  9. Corrective interpersonal experience in psychodrama group therapy: a comprehensive process analysis of significant therapeutic events.

    Science.gov (United States)

    McVea, Charmaine S; Gow, Kathryn; Lowe, Roger

    2011-07-01

    This study investigated the process of resolving painful emotional experience during psychodrama group therapy, by examining significant therapeutic events within seven psychodrama enactments. A comprehensive process analysis of four resolved and three not-resolved cases identified five meta-processes which were linked to in-session resolution. One was a readiness to engage in the therapeutic process, which was influenced by client characteristics and the client's experience of the group; and four were therapeutic events: (1) re-experiencing with insight; (2) activating resourcefulness; (3) social atom repair with emotional release; and (4) integration. A corrective interpersonal experience (social atom repair) healed the sense of fragmentation and interpersonal disconnection associated with unresolved emotional pain, and emotional release was therapeutically helpful when located within the enactment of this new role relationship. Protagonists who experienced resolution reported important improvements in interpersonal functioning and sense of self which they attributed to this experience.

  10. Three-dimensional volumetric display by inclined-plane scanning

    Science.gov (United States)

    Miyazaki, Daisuke; Eto, Takuma; Nishimura, Yasuhiro; Matsushita, Kenji

    2003-05-01

    A volumetric display system based on three-dimensional (3-D) scanning that uses an inclined two-dimensional (2-D) image is described. In the volumetric display system a 2-D display unit is placed obliquely in an imaging system into which a rotating mirror is inserted. When the mirror is rotated, the inclined 2-D image is moved laterally. A locus of the moving image can be observed by persistence of vision as a result of the high-speed rotation of the mirror. Inclined cross-sectional images of an object are displayed on the display unit in accordance with the position of the image plane to observe a 3-D image of the object by persistence of vision. Three-dimensional images formed by this display system satisfy all the criteria for stereoscopic vision. We constructed the volumetric display systems using a galvanometer mirror and a vector-scan display unit. In addition, we constructed a real-time 3-D measurement system based on a light section method. Measured 3-D images can be reconstructed in the 3-D display system in real time.

  11. The efficacy of adult christian support groups in coping with the death of a significant loved one.

    Science.gov (United States)

    Goodman, Herbert; Stone, Mark H

    2009-09-01

    Psychologists sometimes minimize important resources such as religion and spiritual beliefs for coping with bereavement. Alienation of therapeutic psychology from religious values contrasts to professional and public interest in religious experience and commitment. A supportive viewpoint has come about partially as a result of recognizing important values which clinicians have found absent in many of their clients. Until spiritual belief systems become integrated into the work of clinicians, clients may not be fully integrative in coping with loss. The key finding of this study was that individuals who participated in Christian and secular support groups showed no statistically significant difference in their mean endorsement of negative criteria on the BHS, and no statistically significant difference for their mean score endorsement of positive criteria on the RCOPE. However, a Christian-oriented approach was no less effective than a psychological-oriented one. In both groups, a spiritual connection to a specific or generalized higher power was frequently identified which clients ascribed to facilitating the management of their coping.

  12. Displays: Entering a New Dimension

    Science.gov (United States)

    Starkman, Neal

    2007-01-01

    As display technologies prepare to welcome 3-D, the 21st-century classroom will soon bear little resemblance to anything students and teachers have ever seen. In this article, the author presents the latest innovations in the world of digital display technology. These include: (1) Touchlight, an interactive touch screen program that takes a normal…

  13. Comparison of liquid crystal display monitors calibrated with gray-scale standard display function and with γ 2.2 and iPad: observer performance in detection of cerebral infarction on brain CT.

    Science.gov (United States)

    Yoshimura, Kumiko; Nihashi, Takashi; Ikeda, Mitsuru; Ando, Yoshio; Kawai, Hisashi; Kawakami, Kenichi; Kimura, Reiko; Okada, Yumiko; Okochi, Yoshiyuki; Ota, Naotoshi; Tsuchiya, Kenichi; Naganawa, Shinji

    2013-06-01

    The purpose of the study was to compare observer performance in the detection of cerebral infarction on a brain CT using medical-grade liquid crystal display (LCD) monitors calibrated with the gray-scale standard display function and with γ 2.2 and using an iPad with a simulated screen setting. We amassed 97 sample sets, from 47 patients with proven cerebral infarction and 50 healthy control subjects. Nine radiologists independently assessed brain CT on a gray-scale standard display function LCD, a γ 2.2 LCD, and an iPad in random order over 4-week intervals. Receiver operating characteristic (ROC) analysis was performed by using the continuous scale, and the area under the ROC curve (A(z)) was calculated for each monitor. The A(z) values for gray-scale standard display function LCD, γ 2.2 LCD, and iPad were 0.875, 0.884, and 0.839, respectively. The difference among the three monitors was very small. There was no significant difference between gray-scale standard display function LCD and γ 2.2 LCD. However, the A(z) value was statistically significantly smaller for the iPad than the γ 2.2 LCD (p iPad was poorer than that using the other LCDs, the difference was small. Therefore, the iPad could not substitute for other LCD monitors. However, owing to the promising potential advantages of tablet PCs, such as portability, further examination is needed into the clinical use of tablet PCs.

  14. Crystal ball single event display

    International Nuclear Information System (INIS)

    Grosnick, D.; Gibson, A.; Allgower, C.; Alyea, J.; Argonne National Lab., IL

    1997-01-01

    The Single Event Display (SED) is a routine that is designed to provide information graphically about a triggered event within the Crystal Ball. The SED is written entirely in FORTRAN and uses the CERN-based HICZ graphing package. The primary display shows the amount of energy deposited in each of the NaI crystals on a Mercator-like projection of the crystals. Ten different shades and colors correspond to varying amounts of energy deposited within a crystal. Information about energy clusters is displayed on the crystal map by outlining in red the thirteen (or twelve) crystals contained within a cluster and assigning each cluster a number. Additional information about energy clusters is provided in a series of boxes containing useful data about the energy distribution among the crystals within the cluster. Other information shown on the event display include the event trigger type and data about π o 's and η's formed from pairs of clusters as found by the analyzer. A description of the major features is given, along with some information on how to install the SED into the analyzer

  15. Synthetic vision display evaluation studies

    Science.gov (United States)

    Regal, David M.; Whittington, David H.

    1994-01-01

    The goal of this research was to help us understand the display requirements for a synthetic vision system for the High Speed Civil Transport (HSCT). Four experiments were conducted to examine the effects of different levels of perceptual cue complexity in displays used by pilots in a flare and landing task. Increased levels of texture mapping of terrain and runway produced mixed results, including harder but shorter landings and a lower flare initiation altitude. Under higher workload conditions, increased texture resulted in an improvement in performance. An increase in familiar size cues did not result in improved performance. Only a small difference was found between displays using two patterns of high resolution texture mapping. The effects of increased perceptual cue complexity on performance was not as strong as would be predicted from the pilot's subjective reports or from related literature. A description of the role of a synthetic vision system in the High Speed Civil Transport is provide along with a literature review covering applied research related to perceptual cue usage in aircraft displays.

  16. Modeling the Subjective Quality of Highly Contrasted Videos Displayed on LCD With Local Backlight Dimming

    DEFF Research Database (Denmark)

    Mantel, Claire; Bech, Søren; Korhonen, Jari

    2015-01-01

    Local backlight dimming is a technology aiming at both saving energy and improving visual quality on television sets. As the rendition of the image is specified locally, the numerical signal corresponding to the displayed image needs to be computed through a model of the display. This simulated...... signal can then be used as input to objective quality metrics. The focus of this paper is on determining which characteristics of locally backlit displays influence quality assessment. A subjective experiment assessing the quality of highly contrasted videos displayed with various local backlight......-dimming algorithms is set up. Subjective results are then compared with both objective measures and objective quality metrics using different display models. The first analysis indicates that the most significant objective features are temporal variations, power consumption (probably representing leakage...

  17. Prediction of HDR quality by combining perceptually transformed display measurements with machine learning

    Science.gov (United States)

    Choudhury, Anustup; Farrell, Suzanne; Atkins, Robin; Daly, Scott

    2017-09-01

    We present an approach to predict overall HDR display quality as a function of key HDR display parameters. We first performed subjective experiments on a high quality HDR display that explored five key HDR display parameters: maximum luminance, minimum luminance, color gamut, bit-depth and local contrast. Subjects rated overall quality for different combinations of these display parameters. We explored two models | a physical model solely based on physically measured display characteristics and a perceptual model that transforms physical parameters using human vision system models. For the perceptual model, we use a family of metrics based on a recently published color volume model (ICT-CP), which consists of the PQ luminance non-linearity (ST2084) and LMS-based opponent color, as well as an estimate of the display point spread function. To predict overall visual quality, we apply linear regression and machine learning techniques such as Multilayer Perceptron, RBF and SVM networks. We use RMSE and Pearson/Spearman correlation coefficients to quantify performance. We found that the perceptual model is better at predicting subjective quality than the physical model and that SVM is better at prediction than linear regression. The significance and contribution of each display parameter was investigated. In addition, we found that combined parameters such as contrast do not improve prediction. Traditional perceptual models were also evaluated and we found that models based on the PQ non-linearity performed better.

  18. Effects of in-vehicle warning information displays with or without spatial compatibility on driving behaviors and response performance.

    Science.gov (United States)

    Liu, Yung-Ching; Jhuang, Jing-Wun

    2012-07-01

    A driving simulator study was conducted to evaluate the effects of five in-vehicle warning information displays upon drivers' emergent response and decision performance. These displays include visual display, auditory displays with and without spatial compatibility, hybrid displays in both visual and auditory format with and without spatial compatibility. Thirty volunteer drivers were recruited to perform various tasks that involved driving, stimulus-response, divided attention and stress rating. Results show that for displays of single-modality, drivers benefited more when coping with visual display of warning information than auditory display with or without spatial compatibility. However, auditory display with spatial compatibility significantly improved drivers' performance in reacting to the divided attention task and making accurate S-R task decision. Drivers' best performance results were obtained for hybrid display with spatial compatibility. Hybrid displays enabled drivers to respond the fastest and achieve the best accuracy in both S-R and divided attention tasks. Copyright © 2011 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  19. Touch sensitive electrorheological fluid based tactile display

    Science.gov (United States)

    Liu, Yanju; Davidson, Rob; Taylor, Paul

    2005-12-01

    A tactile display is programmable device whose controlled surface is intended to be investigated by human touch. It has a great number of potential applications in the field of virtual reality and elsewhere. In this research, a 5 × 5 tactile display array including electrorheological (ER) fluid has been developed and investigated. Force responses of the tactile display array have been measured while a probe was moved across the upper surface. The purpose of this was to simulate the action of touch performed by human finger. Experimental results show that the sensed surface information could be controlled effectively by adjusting the voltage activation pattern imposed on the tactels. The performance of the tactile display is durable and repeatable. The touch sensitivity of this ER fluid based tactile display array has also been investigated in this research. The results show that it is possible to sense the touching force normal to the display's surface by monitoring the change of current passing through the ER fluid. These encouraging results are helpful for constructing a new type of tactile display based on ER fluid which can act as both sensor and actuator at the same time.

  20. Volumetric, dashboard-mounted augmented display

    Science.gov (United States)

    Kessler, David; Grabowski, Christopher

    2017-11-01

    The optical design of a compact volumetric display for drivers is presented. The system displays a true volume image with realistic physical depth cues, such as focal accommodation, parallax and convergence. A large eyebox is achieved with a pupil expander. The windshield is used as the augmented reality combiner. A freeform windshield corrector is placed at the dashboard.

  1. Flexible Bistable Cholesteric Reflective Displays

    Science.gov (United States)

    Yang, Deng-Ke

    2006-03-01

    Cholesteric liquid crystals (ChLCs) exhibit two stable states at zero field condition-the reflecting planar state and the nonreflecting focal conic state. ChLCs are an excellent candidate for inexpensive and rugged electronic books and papers. This paper will review the display cell structure,materials and drive schemes for flexible bistable cholesteric (Ch) reflective displays.

  2. Multimethods approach to safety-parameter-display evaluation

    International Nuclear Information System (INIS)

    Banks, W.W.; Blackman, H.S.; Gertman, D.I.; Petersen, R.J.

    1982-01-01

    The Human Factors Engineering Office of EG and G Idaho performed this NRC-funded study to assist the NRC in objectively assessing licensee-developed safety parameter display (SPD) formats and designs. The purpose of this study was to quantitatively measure the degree to which a tachistoscopic method of display evaluation would correlate with the results of a multidimensional rating approach to display evaluation. Results of the following three experiments will be presented; (a) tachistoscopic, (b) multidimensional rating scale, and (c) the combined results of a and b. The test material for all experiments consisted of three multivariate data display formats all under development as SPDs for reactor control rooms presenting safety parameter display data at the loss-of-fluid test (LOFT) facility. The three display formats studied were stars, deviation bar graphs, and meters. Eighteen adult volunteers were used as subjects. All were currently qualified reactor operators from the LOFT reactor plant, with a mean of 9.4 years reactor operating experience

  3. Flight test of a head-worn display as an equivalent-HUD for terminal operations

    Science.gov (United States)

    Shelton, K. J.; Arthur, J. J.; Prinzel, L. J.; Nicholas, S. N.; Williams, S. P.; Bailey, R. E.

    2015-05-01

    Research, development, test, and evaluation of flight deck interface technologies is being conducted by NASA to proactively identify, develop, and mature tools, methods, and technologies for improving overall aircraft safety of new and legacy vehicles operating in the Next Generation Air Transportation System (NextGen). Under NASA's Aviation Safety Program, one specific area of research is the use of small Head-Worn Displays (HWDs) as a potential equivalent display to a Head-up Display (HUD). Title 14 of the US CFR 91.175 describes a possible operational credit which can be obtained with airplane equipage of a HUD or an "equivalent"' display combined with Enhanced Vision (EV). A successful HWD implementation may provide the same safety and operational benefits as current HUD-equipped aircraft but for significantly more aircraft in which HUD installation is neither practical nor possible. A flight test was conducted to evaluate if the HWD, coupled with a head-tracker, can provide an equivalent display to a HUD. Approach and taxi testing was performed on-board NASA's experimental King Air aircraft in various visual conditions. Preliminary quantitative results indicate the HWD tested provided equivalent HUD performance, however operational issues were uncovered. The HWD showed significant potential as all of the pilots liked the increased situation awareness attributable to the HWD's unique capability of unlimited field-of-regard.

  4. IDEA: Interactive Display for Evolutionary Analyses.

    Science.gov (United States)

    Egan, Amy; Mahurkar, Anup; Crabtree, Jonathan; Badger, Jonathan H; Carlton, Jane M; Silva, Joana C

    2008-12-08

    The availability of complete genomic sequences for hundreds of organisms promises to make obtaining genome-wide estimates of substitution rates, selective constraints and other molecular evolution variables of interest an increasingly important approach to addressing broad evolutionary questions. Two of the programs most widely used for this purpose are codeml and baseml, parts of the PAML (Phylogenetic Analysis by Maximum Likelihood) suite. A significant drawback of these programs is their lack of a graphical user interface, which can limit their user base and considerably reduce their efficiency. We have developed IDEA (Interactive Display for Evolutionary Analyses), an intuitive graphical input and output interface which interacts with PHYLIP for phylogeny reconstruction and with codeml and baseml for molecular evolution analyses. IDEA's graphical input and visualization interfaces eliminate the need to edit and parse text input and output files, reducing the likelihood of errors and improving processing time. Further, its interactive output display gives the user immediate access to results. Finally, IDEA can process data in parallel on a local machine or computing grid, allowing genome-wide analyses to be completed quickly. IDEA provides a graphical user interface that allows the user to follow a codeml or baseml analysis from parameter input through to the exploration of results. Novel options streamline the analysis process, and post-analysis visualization of phylogenies, evolutionary rates and selective constraint along protein sequences simplifies the interpretation of results. The integration of these functions into a single tool eliminates the need for lengthy data handling and parsing, significantly expediting access to global patterns in the data.

  5. Antecedents and consequences of emotional display rule perceptions.

    Science.gov (United States)

    Diefendorff, James M; Richard, Erin M

    2003-04-01

    Central to all theories of emotional labor is the idea that individuals follow emotional display rules that specify the appropriate expression of emotions on the job. This investigation examined antecedents and consequences of emotional display rule perceptions. Full-time working adults (N = 152) from a variety of occupations provided self-report data, and supervisors and coworkers completed measures pertaining to the focal employees. Results using structural equation modeling revealed that job-based interpersonal requirements, supervisor display rule perceptions, and employee extraversion and neuroticism were predictive of employee display rule perceptions. Employee display rule perceptions, in turn, were related to self-reported job satisfaction and coworker ratings of employees' emotional displays on the job. Finally, neuroticism had direct negative relationships with job satisfaction and coworker ratings of employees' emotional displays.

  6. Elaborate Mimetic Vocal Displays by Female Superb Lyrebirds

    Directory of Open Access Journals (Sweden)

    Anastasia H Dalziell

    2016-04-01

    Full Text Available Some of the most striking vocalizations in birds are made by males that incorporate vocal mimicry in their sexual displays. Mimetic vocalization in females is largely undescribed, but it is unclear whether this is because of a lack of selection for vocal mimicry in females, or whether the phenomenon has simply been overlooked. These issues are thrown into sharp relief in the superb lyrebird, Menura novaehollandiae, a basal oscine passerine with a lek-like mating system and female uniparental care. The spectacular mimetic song display produced by courting male lyrebirds is a textbook example of a sexually selected trait, but the vocalizations of female lyrebirds are largely unknown. Here, we provide the first analysis of the structure and context of the vocalizations of female lyrebirds. Female lyrebirds were completely silent during courtship; however, females regularly produced sophisticated vocal displays incorporating both lyrebird-specific vocalizations and imitations of sounds within their environment. The structure of female vocalizations varied significantly with context. While foraging, females mostly produced a complex lyrebird-specific song, whereas they gave lyrebird-specific alarm calls most often during nest defense. Within their vocal displays females also included a variety of mimetic vocalizations, including imitations of the calls of dangerous predators, and of alarm calls and song of harmless heterospecifics. Females gave more mimetic vocalizations during nest defense than while foraging, and the types of sounds they imitated varied between these contexts, suggesting that mimetic vocalizations have more than one function. These results are inconsistent with previous portrayals of vocalizations by female lyrebirds as rare, functionless by-products of sexual selection on males. Instead, our results support the hypotheses that complex female vocalizations play a role in nest defense and mediate female-female competition for

  7. New portable FELIX 3D display

    Science.gov (United States)

    Langhans, Knut; Bezecny, Daniel; Homann, Dennis; Bahr, Detlef; Vogt, Carsten; Blohm, Christian; Scharschmidt, Karl-Heinz

    1998-04-01

    An improved generation of our 'FELIX 3D Display' is presented. This system is compact, light, modular and easy to transport. The created volumetric images consist of many voxels, which are generated in a half-sphere display volume. In that way a spatial object can be displayed occupying a physical space with height, width and depth. The new FELIX generation uses a screen rotating with 20 revolutions per second. This target screen is mounted by an easy to change mechanism making it possible to use appropriate screens for the specific purpose of the display. An acousto-optic deflection unit with an integrated small diode pumped laser draws the images on the spinning screen. Images can consist of up to 10,000 voxels at a refresh rate of 20 Hz. Currently two different hardware systems are investigated. The first one is based on a standard PCMCIA digital/analog converter card as an interface and is controlled by a notebook. The developed software is provided with a graphical user interface enabling several animation features. The second, new prototype is designed to display images created by standard CAD applications. It includes the development of a new high speed hardware interface suitable for state-of-the- art fast and high resolution scanning devices, which require high data rates. A true 3D volume display as described will complement the broad range of 3D visualization tools, such as volume rendering packages, stereoscopic and virtual reality techniques, which have become widely available in recent years. Potential applications for the FELIX 3D display include imaging in the field so fair traffic control, medical imaging, computer aided design, science as well as entertainment.

  8. Evaluation of tactual displays for flight control

    Science.gov (United States)

    Levison, W. H.; Tanner, R. B.; Triggs, T. J.

    1973-01-01

    Manual tracking experiments were conducted to determine the suitability of tactual displays for presenting flight-control information in multitask situations. Although tracking error scores are considerably greater than scores obtained with a continuous visual display, preliminary results indicate that inter-task interference effects are substantially less with the tactual display in situations that impose high visual scanning workloads. The single-task performance degradation found with the tactual display appears to be a result of the coding scheme rather than the use of the tactual sensory mode per se. Analysis with the state-variable pilot/vehicle model shows that reliable predictions of tracking errors can be obtained for wide-band tracking systems once the pilot-related model parameters have been adjusted to reflect the pilot-display interaction.

  9. Real time speech formant analyzer and display

    Science.gov (United States)

    Holland, George E.; Struve, Walter S.; Homer, John F.

    1987-01-01

    A speech analyzer for interpretation of sound includes a sound input which converts the sound into a signal representing the sound. The signal is passed through a plurality of frequency pass filters to derive a plurality of frequency formants. These formants are converted to voltage signals by frequency-to-voltage converters and then are prepared for visual display in continuous real time. Parameters from the inputted sound are also derived and displayed. The display may then be interpreted by the user. The preferred embodiment includes a microprocessor which is interfaced with a television set for displaying of the sound formants. The microprocessor software enables the sound analyzer to present a variety of display modes for interpretive and therapeutic used by the user.

  10. Transparent 3D display for augmented reality

    Science.gov (United States)

    Lee, Byoungho; Hong, Jisoo

    2012-11-01

    Two types of transparent three-dimensional display systems applicable for the augmented reality are demonstrated. One of them is a head-mounted-display-type implementation which utilizes the principle of the system adopting the concave floating lens to the virtual mode integral imaging. Such configuration has an advantage in that the threedimensional image can be displayed at sufficiently far distance resolving the accommodation conflict with the real world scene. Incorporating the convex half mirror, which shows a partial transparency, instead of the concave floating lens, makes it possible to implement the transparent three-dimensional display system. The other type is the projection-type implementation, which is more appropriate for the general use than the head-mounted-display-type implementation. Its imaging principle is based on the well-known reflection-type integral imaging. We realize the feature of transparent display by imposing the partial transparency to the array of concave mirror which is used for the screen of reflection-type integral imaging. Two types of configurations, relying on incoherent and coherent light sources, are both possible. For the incoherent configuration, we introduce the concave half mirror array, whereas the coherent one adopts the holographic optical element which replicates the functionality of the lenslet array. Though the projection-type implementation is beneficial than the head-mounted-display in principle, the present status of the technical advance of the spatial light modulator still does not provide the satisfactory visual quality of the displayed three-dimensional image. Hence we expect that the head-mounted-display-type and projection-type implementations will come up in the market in sequence.

  11. New developments in flexible cholesteric liquid crystal displays

    Science.gov (United States)

    Schneider, Tod; Davis, Donald J.; Franklin, Sean; Venkataraman, Nithya; McDaniel, Diaz; Nicholson, Forrest; Montbach, Erica; Khan, Asad; Doane, J. William

    2007-02-01

    Flexible Cholesteric liquid crystal displays have been rapidly maturing into a strong contender in the flexible display market. Encapsulation of the Cholesteric liquid crystal permits the use of flexible plastic substrates and roll-to-roll production. Recent advances include ultra-thin displays, laser-cut segmented displays of variable geometry, and smart card applications. Exciting technologies such as simultaneous laser-edge sealing and singulation enable high volume production, excellent quality control and non-traditional display geometries and formats.

  12. A system for tracking braille readers using a Wii Remote and a refreshable braille display.

    Science.gov (United States)

    Aranyanak, Inthraporn; Reilly, Ronan G

    2013-03-01

    This article describes a cheap and easy-to-use finger-tracking system for studying braille reading. It provides improved spatial and temporal resolution over the current available solutions and can be used with either a refreshable braille display or braille-embossed paper. In conjunction with a refreshable braille display, the tracking system has the unique capacity to implement display-change paradigms derived from sighted reading research. This will allow researchers to probe skilled braille reading in significantly more depth than has heretofore been possible.

  13. Guide-09-1998. Quality control of darkrooms and image display devices

    International Nuclear Information System (INIS)

    2015-01-01

    This guide is applicable to process darkrooms relieved and receiving devices and image displays. A number of methods which require the appointed instrumentation described, some of which can be implemented in own radiology services in the country given the low complexity of themselves and others that require specific equipment and can be performed by specialized groups external to these units.

  14. 27 CFR 6.35 - Renting display space.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Renting display space. 6.35 Section 6.35 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU... Renting display space. The renting of display space by an industry member at a retail establishment...

  15. 27 CFR 6.56 - Renting display space.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Renting display space. 6.56 Section 6.56 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU... Distribution Service § 6.56 Renting display space. A promotion whereby an industry member rents display space...

  16. 14 CFR 255.4 - Display of information.

    Science.gov (United States)

    2010-01-01

    ... REGULATIONS AIRLINE COMPUTER RESERVATIONS SYSTEMS § 255.4 Display of information. (a) All systems shall provide at least one integrated display that includes the schedules, fares, rules, and availability of all... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Display of information. 255.4 Section 255.4...

  17. Projection display industry market and technology trends

    Science.gov (United States)

    Castellano, Joseph A.; Mentley, David E.

    1995-04-01

    The projection display industry is diverse, embracing a variety of technologies and applications. In recent years, there has been a high level of interest in projection displays, particularly those using LCD panels or light valves because of the difficulty in making large screen, direct view displays. Many developers feel that projection displays will be the wave of the future for large screen HDTV (high-definition television), penetrating the huge existing market for direct view CRT-based televisions. Projection displays can have the images projected onto a screen either from the rear or the front; the main characteristic is their ability to be viewed by more than one person. In addition to large screen home television receivers, there are numerous other uses for projection displays including conference room presentations, video conferences, closed circuit programming, computer-aided design, and military command/control. For any given application, the user can usually choose from several alternative technologies. These include CRT front or rear projectors, LCD front or rear projectors, LCD overhead projector plate monitors, various liquid or solid-state light valve projectors, or laser-addressed systems. The overall worldwide market for projection information displays of all types and for all applications, including home television, will top DOL4.6 billion in 1995 and DOL6.45 billion in 2001.

  18. Advanced and tendencies in the development of display technologies

    Science.gov (United States)

    Kompanets, I. N.

    2006-06-01

    Advances and key display applications are discussed. Computer, compact mobile, TV and collective large screen displays are mentioned. Flat panel displays step on CRT devices to leave them behind in 2007. Materials, active matricies and applications of bright radiative field emission and organic LED displays are developing successively and pressing other technologies to be used in photo-cameras, cellular phones, auto-cars and avionics. Progress in flexible screens can substantially extend the display design and application soon. 3D display systems are under intensive development, and laser is an important unit in some vaiants of holographic and volumetric 3D displays. Value forecast of different display markets is presented.

  19. Color Analysis in Air Traffic Control Displays, Part II. Auxiliary Displays

    National Research Council Canada - National Science Library

    Xing, Jing

    2007-01-01

    ...), Traffic Management Advisor (TMA), and Integrated Terminal Weather System (ITWS). For each display, we documented the background and default colors, color-coding, color usage, associated purposes of color use, and color complexity...

  20. Design and Evaluation of a Thermal Tactile Display for Colour Rendering

    Directory of Open Access Journals (Sweden)

    Zhen Jia

    2015-11-01

    Full Text Available This paper proposes a novel method of manipulating both thermal change rate and thermal intensity to convey colour information by using a thermal tactile display. The colour-space transformation from {red, green, blue} to {hue, saturation, intensity} is introduced, and the mapping between colour and temperature is established based on warm and cold colours. Considering the lower resolution of the tactile channel, six limited stimulation levels are generated to represent colours. Based on the semi-infinite body model, the thermal response within the skin for each stimulation form is investigated. The Peltier element of the display is designed to convey different thermal stimuli to the human finger. Two experiments are performed to evaluate the performance of the display: colour identification and discrimination. Experimental results indicate that there is a response bias among the perceived colours for the traditional method of only employing thermal intensity, but there is no response bias for the proposed method; subjects’ mean recognition accuracy with the proposed method is significantly higher than that gained using the traditional method. Furthermore, colour information of the captured images can be reliably discriminated by using this devised thermal tactile display.

  1. Irradiation from video display terminals

    International Nuclear Information System (INIS)

    Backe, S.; Hannevik, M.

    1987-01-01

    Video display terminals (VDT's) are in common use by computer operators. In the last years this group of workers has expressed growing concern about their work environment and possible hazardious effects in connection with radiation emission from VDT's. Radiation types and levels of emission and possible biological effects have been the subject of research activity in Norway and in other countries. This report summarizes the various radiation types and their levels of emission from VDT's. An overview of recent epidemiological studies and animal experiments, and the conclusions given by the research groups are also presented. The conclusions drawn in this report based on the current knowledge are: Radiation, other than low frequency pulsed magnetic fields, have low and negligible emission levels and will not represent any health hazard to VDT-operator or to the foetus of pregnant operators. The biological effects of low frequency pulsed mangetic fields have been the subject of epidemiological studies and animal experiments. Epidemiological studies carried out in Canada, Finland, Sweden and Norway gave no support for any correlation between pregnancy complications and operation of VDT's. From animal experiments it has so far been impossible to assert an effect on pregnancy outcome from low frequency pulsed magnetic fields

  2. Visual Merchandising through Display: Advertising Services Occupations.

    Science.gov (United States)

    Maurer, Nelson S.

    The increasing use of displays by businessmen is creating a demand for display workers. This demand may be met by preparing high school students to enter the field of display. Additional workers might be recruited by offering adult training programs for individuals working within the stores. For this purpose a curriculum guide has been developed…

  3. 14 CFR 125.7 - Display of certificate.

    Science.gov (United States)

    2010-01-01

    ... OR MORE; AND RULES GOVERNING PERSONS ON BOARD SUCH AIRCRAFT General § 125.7 Display of certificate. (a) The certificate holder must display a true copy of the certificate in each of its aircraft. (b... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Display of certificate. 125.7 Section 125.7...

  4. [Peptide phage display in biotechnology and biomedicine].

    Science.gov (United States)

    Kuzmicheva, G A; Belyavskaya, V A

    2016-07-01

    To date peptide phage display is one of the most common combinatorial methods used for identifying specific peptide ligands. Phage display peptide libraries containing billions different clones successfully used for selection of ligands with high affinity and selectivity toward wide range of targets including individual proteins, bacteria, viruses, spores, different kind of cancer cells and variety of nonorganic targets (metals, alloys, semiconductors etc.) Success of using filamentous phage in phage display technologies relays on the robustness of phage particles and a possibility to genetically modify its DNA to construct new phage variants with novel properties. In this review we are discussing characteristics of the most known non-commercial peptide phage display libraries of different formats (landscape libraries in particular) and their successful applications in several fields of biotechnology and biomedicine: discovery of peptides with diagnostic values against different pathogens, discovery and using of peptides recognizing cancer cells, trends in using of phage display technologies in human interactome studies, application of phage display technologies in construction of novel nano materials.

  5. Industrial Personal Computer based Display for Nuclear Safety System

    International Nuclear Information System (INIS)

    Kim, Ji Hyeon; Kim, Aram; Jo, Jung Hee; Kim, Ki Beom; Cheon, Sung Hyun; Cho, Joo Hyun; Sohn, Se Do; Baek, Seung Min

    2014-01-01

    The safety display of nuclear system has been classified as important to safety (SIL:Safety Integrity Level 3). These days the regulatory agencies are imposing more strict safety requirements for digital safety display system. To satisfy these requirements, it is necessary to develop a safety-critical (SIL 4) grade safety display system. This paper proposes industrial personal computer based safety display system with safety grade operating system and safety grade display methods. The description consists of three parts, the background, the safety requirements and the proposed safety display system design. The hardware platform is designed using commercially available off-the-shelf processor board with back plane bus. The operating system is customized for nuclear safety display application. The display unit is designed adopting two improvement features, i.e., one is to provide two separate processors for main computer and display device using serial communication, and the other is to use Digital Visual Interface between main computer and display device. In this case the main computer uses minimized graphic functions for safety display. The display design is at the conceptual phase, and there are several open areas to be concreted for a solid system. The main purpose of this paper is to describe and suggest a methodology to develop a safety-critical display system and the descriptions are focused on the safety requirement point of view

  6. Industrial Personal Computer based Display for Nuclear Safety System

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji Hyeon; Kim, Aram; Jo, Jung Hee; Kim, Ki Beom; Cheon, Sung Hyun; Cho, Joo Hyun; Sohn, Se Do; Baek, Seung Min [KEPCO, Youngin (Korea, Republic of)

    2014-08-15

    The safety display of nuclear system has been classified as important to safety (SIL:Safety Integrity Level 3). These days the regulatory agencies are imposing more strict safety requirements for digital safety display system. To satisfy these requirements, it is necessary to develop a safety-critical (SIL 4) grade safety display system. This paper proposes industrial personal computer based safety display system with safety grade operating system and safety grade display methods. The description consists of three parts, the background, the safety requirements and the proposed safety display system design. The hardware platform is designed using commercially available off-the-shelf processor board with back plane bus. The operating system is customized for nuclear safety display application. The display unit is designed adopting two improvement features, i.e., one is to provide two separate processors for main computer and display device using serial communication, and the other is to use Digital Visual Interface between main computer and display device. In this case the main computer uses minimized graphic functions for safety display. The display design is at the conceptual phase, and there are several open areas to be concreted for a solid system. The main purpose of this paper is to describe and suggest a methodology to develop a safety-critical display system and the descriptions are focused on the safety requirement point of view.

  7. Viewpoint adaptive display of HDR images

    DEFF Research Database (Denmark)

    Forchhammer, Søren; Mantel, Claire

    2017-01-01

    In this paper viewpoint adaptive display of HDR images incorporating the effects of ambient light is presented and evaluated. LED backlight displays may render HDR images, but while at a global scale a high dynamic range may be achieved, locally the contrast is limited by the leakage of light...... through the LC elements of the display. To render high quality images, the display with backlight dimming can compute the values of the LED backlight and LC elements based on the input image, information about the viewpoint of the observer(s) and information of the ambient light. The goal is to achieve...... the best perceptual reproduction of the specified target image derived from the HDR input image in the specific viewing situation including multiple viewers, possibly having different preferences. An optimization based approach is presented. Some tests with reproduced images are also evaluated subjectively...

  8. Development and validation of a measure of display rule knowledge: the display rule assessment inventory.

    Science.gov (United States)

    Matsumoto, David; Yoo, Seung Hee; Hirayama, Satoko; Petrova, Galina

    2005-03-01

    As one component of emotion regulation, display rules, which reflect the regulation of expressive behavior, have been the topic of many studies. Despite their theoretical and empirical importance, however, to date there is no measure of display rules that assesses a full range of behavioral responses that are theoretically possible when emotion is elicited. This article reports the development of a new measure of display rules that surveys 5 expressive modes: expression, deamplification, amplification, qualification, and masking. Two studies provide evidence for its internal and temporal reliability and for its content, convergent, discriminant, external, and concurrent predictive validity. Additionally, Study 1, involving American, Russian, and Japanese participants, demonstrated predictable cultural differences on each of the expressive modes. Copyright 2005 APA, all rights reserved.

  9. A novel approach to patient self-monitoring of sonographic examinations using a head-mounted display.

    Science.gov (United States)

    Inoue, Masaharu; Kihara, Kazunori; Yoshida, Soichiro; Ito, Masaya; Takeshita, Hideki; Ishioka, Junichiro; Matsuoka, Yoh; Numao, Noboru; Saito, Kazutaka; Fujii, Yasuhisa

    2015-01-01

    Patients' use of a head-mounted display during their sonographic examinations could provide them with information about their diseases in real time and might help improve "patient-centered care." We conducted this prospective study to evaluate the feasibility of a modern head-mounted display for patient self-monitoring of sonographic examinations. In November and December 2013, 58 patients were enrolled. Patients wore a head-mounted display (HMZ-T2; Sony Corporation, Tokyo, Japan) during their sonographic examinations and watched their own images in real time. After the sonographic examinations, the patients completed a questionnaire, in which they evaluated the utility of the head-mounted display, their understanding of their diseases, their satisfaction with using the head-mounted display, and any adverse events. Until November 26, 2013, patients' names were requested on the questionnaire; after that date, the questionnaire was changed to be anonymous. Of the 58 patients, 56 (97%) elected to participate in this study. The head-mounted display was reported to have good image quality by 42 patients (75%) and good wearability by 39 (70%). Thirty-six patients (64%) reported they had deepened their understanding of their diseases. There were no major complications, and only 2 patients (4%) had mild eye fatigue. There was no significant association between questionnaire results and patient characteristics. None of the questionnaire results changed significantly after the questionnaire was made anonymous. The use of a modern head-mounted display by patients during sonographic examinations provided good image quality with acceptable wearability. It could deepen their understanding of their diseases and help develop patient-centered care. © 2015 by the American Institute of Ultrasound in Medicine.

  10. Display analysis with the optimal control model of the human operator. [pilot-vehicle display interface and information processing

    Science.gov (United States)

    Baron, S.; Levison, W. H.

    1977-01-01

    Application of the optimal control model of the human operator to problems in display analysis is discussed. Those aspects of the model pertaining to the operator-display interface and to operator information processing are reviewed and discussed. The techniques are then applied to the analysis of advanced display/control systems for a Terminal Configured Vehicle. Model results are compared with those obtained in a large, fixed-base simulation.

  11. Digital image display system for emergency room

    International Nuclear Information System (INIS)

    Murry, R.C.; Lane, T.J.; Miax, L.S.

    1989-01-01

    This paper reports on a digital image display system for the emergency room (ER) in a major trauma hospital. Its objective is to reduce radiographic image delivery time to a busy ER while simultaneously providing a multimodality capability. Image storage, retrieval, and display will also be facilitated with this system. The system's backbone is a token-ring network of RISC and personal computers. The display terminals are higher- function RISC computers with 1,024 2 color or gray-scale monitors. The PCs serve as administrative terminals. Nuclear medicine, CT, MR, and digitized film images are transferred to the image display system

  12. Impact of a point-of-sale tobacco display ban on smokers' spontaneous purchases: comparisons from postpurchase interviews before and after the ban in Western Australia.

    Science.gov (United States)

    Carter, Owen B J; Phan, Tina; Mills, Brennen W

    2015-03-01

    To assess the impact of the Western Australian tobacco point-of-sale display ban on spontaneous purchase behaviours. Daily adult smokers (n=402) observed purchasing cigarettes were recruited via exit interviews either 2 months before or after the implementation of the display ban. Smokers were asked if they had intended to purchase cigarettes before entering the store to assess spontaneous purchase behaviours. Whether smokers had noticed the displays before their purchase and the extent to which this influenced their purchase decision was also assessed via non-prompting questions. When compared with before the ban, fewer smokers after the ban noticed the displays (27.1% vs 1.1%, pmaking spontaneous purchases (28.2% vs 19.8%, ppurchase decisions (free recall 5.0% vs 1.1%, ppurchasers were more likely than planned purchasers to suggest the displays influenced their purchase decisions (free recall 9.7% vs 3.2%, ppurchasers nominating the influence of displays fell substantially (free recall 9.7% vs 5.6%, p=NS; cued recall 40.0% vs 11.1%, ppurchasers (free recall 3.2% vs 0.0%, pmaking spontaneous tobacco purchases after implementation of the Western Australian tobacco display ban and between a fivefold and sixfold reduction in the proportion suggesting displays influenced their decision to purchase cigarettes. These data are consistent with previous research suggesting tobacco displays encourage spontaneous purchases and their removal corresponds to reductions in the same. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  13. Short-Term Omega 3 Fatty Acids Treatment for Dry Eye in Young and Middle-Aged Visual Display Terminal Users.

    Science.gov (United States)

    Bhargava, Rahul; Kumar, Prachi; Arora, Yogesh

    2016-07-01

    To evaluate the effect of an omega 3 fatty acid (O3FA) oral supplement (2,400 mg/day) for 45 days on dry eye symptoms, tear production, stability, and conjunctival cytology in young and middle-aged visual display terminal (VDT) users. Institutional review board approval was obtained, and a randomized, double-blind, interventional study was done; eyes of 256 VDT users were randomized to receive 4 capsules twice daily for 45 days (O3FA group), each containing 180 mg of eicosapentaenoic acid and 120 mg docosahexaenoic acid. The O3FA group was compared with another group (n=266) who received 8 capsules of a placebo (olive oil). Patients were evaluated at baseline, 30 days, and 45 days. The primary outcome measure was an improvement in dry eye symptoms. Secondary outcome measures were improvement in the Nelson grade on conjunctival impression cytology, Schirmer test values, and tear film breakup time (TBUT). Means of groups (pretreatment, day 30, and day 45) were compared with repeated-measure analysis of variance. The relation between the outcome variables and VDT time was evaluated using linear regression. In the O3FA group, the mean symptom score differed significantly (P<0.005) (pretreatment, 30 days, and 45 days); the TBUT and Nelson grade also improved significantly but only after 45 days of intervention. Schirmer test values did not differ significantly after adjustment for multiple comparisons (P=0.010). The change was not significant in the placebo group. Consumption of 2,400 mg/day of O3FA supplement improves symptoms, tear stability, and conjunctival cytology but not tear production in symptomatic VDT users.

  14. Research on Visual Display Integration for Advanced Fighter Aircraft.

    Science.gov (United States)

    1978-11-01

    V— V . — I 22 February 1979 ERRATA: AMBL-TR-78-97, RESEARC H ON...speculated , the matrix format technologies (plasnias , LC’s, and LED’S) have made significant inroads to the display market for alpha— • numerics and...applications in the consumer/industrial market . Countering the trend a recent article (Reference (61)) indicates some current interest in using a laser

  15. 76 FR 28312 - Safety Zones; Fireworks Display Kanawha River, WV

    Science.gov (United States)

    2011-05-17

    ... West Virginia Special Olympics Fireworks Display, is located between mile 57.9 and 58.9 in Charleston... expect the economic impact of this rule to be so minimal that a full Regulatory Evaluation is unnecessary... significant economic impact on a substantial number of small entities. The term ``small entities'' comprises...

  16. Helmet-mounted display requirements: just another head-up display (HUD) or a different animal altogether?

    Science.gov (United States)

    Newman, Richard L.; Haworth, Loran A.

    1994-06-01

    The helmet-mounted display (HMD) presents flight, navigation, and weapon information in the pilot's line of sight. The HMD was developed to allow the pilot to retain aircraft and weapon information while looking off boresight. The present study reviewed the state-of-the-art in HMDs and identified a number of issues applying to HMDs. Several are identical to head-up display (HUD) issues: symbol standardization, excessive clutter, and the need for integration with other cockpit displays and controls. Other issues are unique to the head-mounted display: symbol stabilization, inadequate definitions, undefined symbol drive laws, helmet considerations, and field-of-view (FOV) vs. resolution tradeoff requirements. Symbol stabilization is critical. In the Apache helicopter, the lack of compensation for pilot head motion creates excessive workload during hovering and nap-of-the-earth (NOE) flight. This high workload translates into excessive training requirements. At the same time, misleading symbology makes interpretation of the height of obstructions impossible. The underlying cause is the absence of design criteria for HMDs. The existing military standard does not reflect the current state of technology. In addition, there are inadequate test and evaluation guidelines. The situation parallels the situation for HUDs several years ago.

  17. Nonlinear mapping of the luminance in dual-layer high dynamic range displays

    Science.gov (United States)

    Guarnieri, Gabriele; Ramponi, Giovanni; Bonfiglio, Silvio; Albani, Luigi

    2009-02-01

    It has long been known that the human visual system (HVS) has a nonlinear response to luminance. This nonlinearity can be quantified using the concept of just noticeable difference (JND), which represents the minimum amplitude of a specified test pattern an average observer can discern from a uniform background. The JND depends on the background luminance following a threshold versus intensity (TVI) function. It is possible to define a curve which maps physical luminances into a perceptually linearized domain. This mapping can be used to optimize a digital encoding, by minimizing the visibility of quantization noise. It is also commonly used in medical applications to display images adapting to the characteristics of the display device. High dynamic range (HDR) displays, which are beginning to appear on the market, can display luminance levels outside the range in which most standard mapping curves are defined. In particular, dual-layer LCD displays are able to extend the gamut of luminance offered by conventional liquid crystals towards the black region; in such areas suitable and HVS-compliant luminance transformations need to be determined. In this paper we propose a method, which is primarily targeted to the extension of the DICOM curve used in medical imaging, but also has a more general application. The method can be modified in order to compensate for the ambient light, which can be significantly greater than the black level of an HDR display and consequently reduce the visibility of the details in dark areas.

  18. Digital Display Integration Project Project Online 2.0

    CERN Document Server

    Bardsley, J N

    1999-01-01

    The electronic display industry is changing in three important ways. First, the dominance of the cathode ray tube (CRT) is being challenged by the development of flat panel displays (FPDs). This will lead to the availability of displays of higher performance, albeit at greater cost. Secondly, the analog interfaces between displays that show data and the computers that generate the data are being replaced by digital connections. Finally, a high-resolution display is becoming the most expensive component in computer system for homes and small offices. It is therefore desirable that the useful lifetime of the display extend over several years and that the electronics allows the display to be used with many different image sources. Hopefully, the necessity of having three or four large CRTs in one office to accommodate different computer operating systems or communication protocols will soon disappear. Instead, we hope to see a set of flat panels that can be switched to show several independent images from multip...

  19. Diagnostic accuracy of different display types in detection of recurrent caries under restorations by using CBCT.

    Science.gov (United States)

    Baltacıoĝlu, İsmail H; Eren, Hakan; Yavuz, Yasemin; Kamburoğlu, Kıvanç

    To assess the in vitro diagnostic ability of CBCT images using seven different display types in the detection of recurrent caries. Our study comprised 128 extracted human premolar and molar teeth. 8 groups each containing 16 teeth were obtained as follows: (1) Black Class I (Occlusal) amalgam filling without caries; (2) Black Class I (Occlusal) composite filling without caries; (3) Black Class II (Proximal) amalgam filling without caries; (4) Black Class II (Proximal) composite filling without caries; (5) Black Class I (Occlusal) amalgam filling with caries; (6) Black Class I (Occlusal) composite filling with caries; (7) Black Class II (Proximal) amalgam filling with caries; and (8) Black Class II (Proximal) composite filling with caries. Teeth were imaged using 100 × 90 mm field of view at three different voxel sizes of a CBCT unit (Planmeca ProMax(®) 3D ProFace™; Planmeca, Helsinki, Finland). CBCT TIFF images were opened and viewed using custom-designed software for computers on different display types. Intra- and interobserver agreements were calculated. The highest area under the receiver operating characteristic curve (Az) values for each image type, observer, reading and restoration were compared using z-tests against Az = 0.5. The significance level was set at p = 0.05. We found poor and moderate agreements. In general, Az values were found when software and medical diagnostic monitor were utilized. For Observer 2, Az values were statistically significantly higher when software was used on medical monitor [p = 0.036, p = 0.015 and p = 0.002, for normal-resolution mode (0.200 mm(3) voxel size), high-resolution mode (0.150 mm(3) voxel size) and low-resolution mode (0.400 mm(3) voxel size), respectively]. No statistically significant differences were found among other display types for all modes (p > 0.05). In general, no difference was found among 3 different voxel sizes (p > 0.05). In general, higher Az values were

  20. Diagnostic accuracy of different display types in detection of recurrent caries under restorations by using CBCT

    Science.gov (United States)

    Baltacıoĝlu, İsmail H; Eren, Hakan; Yavuz, Yasemin

    2016-01-01

    Objectives: To assess the in vitro diagnostic ability of CBCT images using seven different display types in the detection of recurrent caries. Methods: Our study comprised 128 extracted human premolar and molar teeth. 8 groups each containing 16 teeth were obtained as follows: (1) Black Class I (Occlusal) amalgam filling without caries; (2) Black Class I (Occlusal) composite filling without caries; (3) Black Class II (Proximal) amalgam filling without caries; (4) Black Class II (Proximal) composite filling without caries; (5) Black Class I (Occlusal) amalgam filling with caries; (6) Black Class I (Occlusal) composite filling with caries; (7) Black Class II (Proximal) amalgam filling with caries; and (8) Black Class II (Proximal) composite filling with caries. Teeth were imaged using 100 × 90 mm field of view at three different voxel sizes of a CBCT unit (Planmeca ProMax® 3D ProFace™; Planmeca, Helsinki, Finland). CBCT TIFF images were opened and viewed using custom-designed software for computers on different display types. Intra- and interobserver agreements were calculated. The highest area under the receiver operating characteristic curve (Az) values for each image type, observer, reading and restoration were compared using z-tests against Az = 0.5. The significance level was set at p = 0.05. Results: We found poor and moderate agreements. In general, Az values were found when software and medical diagnostic monitor were utilized. For Observer 2, Az values were statistically significantly higher when software was used on medical monitor [p = 0.036, p = 0.015 and p = 0.002, for normal-resolution mode (0.200 mm3 voxel size), high-resolution mode (0.150 mm3 voxel size) and low-resolution mode (0.400 mm3 voxel size), respectively]. No statistically significant differences were found among other display types for all modes (p > 0.05). In general, no difference was found among 3 different voxel sizes (p > 0.05). In general

  1. Measuring the Food Environment: A Systematic Technique for Characterizing Food Stores Using Display Counts

    Directory of Open Access Journals (Sweden)

    Cassandra Miller

    2012-01-01

    Full Text Available Marketing research has documented the influence of in-store characteristics—such as the number and placement of display stands—on consumer purchases of a product. However, little information exists on this topic for key foods of interest to those studying the influence of environmental changes on dietary behavior. This study demonstrates a method for characterizing the food environment by measuring the number of separate displays of fruits, vegetables, and energy-dense snack foods (including chips, candies, and sodas and their proximity to cash registers in different store types. Observations in New Orleans stores (N=172 in 2007 and 2008 revealed significantly more displays of energy-dense snacks than of fruits and vegetables within all store types, especially supermarkets. Moreover, supermarkets had an average of 20 displays of energy-dense snacks within 1 meter of their cash registers, yet none of them had even a single display of fruits or vegetables near their cash registers. Measures of the number of separate display stands of key foods and their proximity to a cash register can be used by researchers to better characterize food stores and by policymakers to address improvements to the food environment.

  2. Ergonomic design of an overview display in a nuclear power plant control room. Integrated process status overview

    International Nuclear Information System (INIS)

    Bouwmeester, R.

    1996-03-01

    A major modification of the Borssele Nuclear Power Plant (NPP), scheduled in 1997, includes the installation of a new Integrated Process Status Overview (IPSO) display in the extensively modified control room. The IPSO display is to promote effective communications among all individuals present in the control room with a clear overview of the main process systems. The flexible LCD rear-projection technique is selected for the replacement of the existing IPSO display with engraved process symbols and hard-wired LEDs. The relation between the IPSO display and the CRT based Process Presentation System (PPS) is described after an elaborate introduction to the nuclear technology and the modification project. The followed IPSO design methodology includes interviews with all IPSO user groups to acquire their experience and comment on the current IPSO in order to enhance the functionality and the acceptance of the new IPSO graphics. The ergonomic design requirements for the new IPSO display concern both generic aspects of information presentation on human-machine interfaces, as well as specific issues related to the selected LCD rear-projection technique. Intermediate stages in the design of the IPSO graphics are outlined as well as the results of the concept evaluation by the user groups. For special interest the functionality of a three dimensional (3-D) display was explored. The design study concludes with a 'final' IPSO graphics design to be used for evaluations on the control room simulator. The presentation of one graphic was found to be most appropriate with adjustment of colour (grey) of components and systems which do not need to operate during the current process conditions or plant mode. (orig.)

  3. Advanced image display systems in radiology

    International Nuclear Information System (INIS)

    Wendler, T.

    1987-01-01

    Advanced image display systems for the fully digital diagnostic imaging departments of the future will be far more than simple replacements of the traditional film-viewing equipment. The new capabilities of very high resolution and highly dynamic displays offer a userfriendly and problem-oriented way of image interpretation. Advanced harware-, software- and human-machine interaction-concepts have been outlined. A scenario for a future way of handling and displaying images, reflecting a new image viewing paradigm in radiology is sketched which has been realized in an experimental image workstation model in the laboratory which, despite its technical complexity, offers a consistent strategy for fast and convenient interaction with image objects. The perspective of knowledge based techniques for workstation control software with object-oriented programming environments and user- and task-adaptive behavior leads to more advanced display properties and a new quality of userfriendliness. 2 refs.; 5 figs

  4. Qualitative analysis of decision making by speech-language pathologists in the design of aided visual displays.

    Science.gov (United States)

    McFadd, Emily; Wilkinson, Krista

    2010-06-01

    For children with complex communication needs, augmentative and alternative communication (AAC) devices offer a functional way to communicate thoughts and feelings. Despite many significant advances in the field, effective and efficient aided communication can remain a challenge for some clients and their partners. One critical element of aided AAC intervention is systematic attention to the design of the communication display itself. A well-designed display will foster communication outcomes; a poorly designed one might have the opposite effect. Surprisingly, to our knowledge there are no studies of the strategies that clinicians actually employ when putting together a display. In this research note, we examine, on a case-by-case basis, the strategies six clinicians used when constructing display pages, as a means of highlighting potential areas that might warrant systematic research on display design.

  5. Three-dimensional display improves observer speed and accuracy

    International Nuclear Information System (INIS)

    Nelson, J.A.; Rowberg, A.H.; Kuyper, S.; Choi, H.S.

    1989-01-01

    In an effort to evaluate the potential cost-effectiveness of three-dimensional (3D) display equipment, we compared the speed and accuracy of experienced radiologists identifying in sliced uppercase letters from CT scans with 2D and pseudo-3D display. CT scans of six capital letters were obtained and printed as a 2D display or as a synthesized pseudo-3D display (Pixar). Six observes performed a timed identification task. Radiologists read the 3D display an average of 16 times faster than the 2D, and the average error rate of 2/6 (± 0.6/6) for 2D interpretations was totally eliminated. This degree of improvement in speed and accuracy suggests that the expense of 3D display may be cost-effective in a defined clinical setting

  6. IDEA: Interactive Display for Evolutionary Analyses

    Directory of Open Access Journals (Sweden)

    Carlton Jane M

    2008-12-01

    Full Text Available Abstract Background The availability of complete genomic sequences for hundreds of organisms promises to make obtaining genome-wide estimates of substitution rates, selective constraints and other molecular evolution variables of interest an increasingly important approach to addressing broad evolutionary questions. Two of the programs most widely used for this purpose are codeml and baseml, parts of the PAML (Phylogenetic Analysis by Maximum Likelihood suite. A significant drawback of these programs is their lack of a graphical user interface, which can limit their user base and considerably reduce their efficiency. Results We have developed IDEA (Interactive Display for Evolutionary Analyses, an intuitive graphical input and output interface which interacts with PHYLIP for phylogeny reconstruction and with codeml and baseml for molecular evolution analyses. IDEA's graphical input and visualization interfaces eliminate the need to edit and parse text input and output files, reducing the likelihood of errors and improving processing time. Further, its interactive output display gives the user immediate access to results. Finally, IDEA can process data in parallel on a local machine or computing grid, allowing genome-wide analyses to be completed quickly. Conclusion IDEA provides a graphical user interface that allows the user to follow a codeml or baseml analysis from parameter input through to the exploration of results. Novel options streamline the analysis process, and post-analysis visualization of phylogenies, evolutionary rates and selective constraint along protein sequences simplifies the interpretation of results. The integration of these functions into a single tool eliminates the need for lengthy data handling and parsing, significantly expediting access to global patterns in the data.

  7. To 'display' or not to 'display'- that is the peptide

    CSIR Research Space (South Africa)

    Crampton, Michael C

    2008-11-01

    Full Text Available eukaryotic and prokaryotic systems but has mainly focused around phages (Etz et al, 2001), yeast (Kondo and Ueda, 2004) and bacteria (Lee et al 2003). The central variable domain of the FliC protein is dispensable and can be used for the insertion and display...

  8. Functional displays

    International Nuclear Information System (INIS)

    Angelis De, F.; Haentjens, J.

    1995-01-01

    The Functional Displays are directly derived from the Man-Machine Design key document: Function-Based Task Analysis. The presentation defines and describes the goals-means structure of the plant function along with applicable control volumes and parameters of interest. The purpose of the subject is to show, through an example of a preliminary design, what the main parts of a function are. (3 figs.)

  9. Display hardware

    International Nuclear Information System (INIS)

    Myers, D.R.

    1983-01-01

    To appreciate the limitations and possibilities of computer graphics it is necessary to have some acquaintance with the available technology. The aim of this chapter is to mention briefly the different display types and their 'ball-park' price ranges. It must be stressed that prices change rapidly, and so those quoted here are only intended to give an idea of the cost at the time of writing.

  10. A visual-display and storage device

    Science.gov (United States)

    Bosomworth, D. R.; Moles, W. H.

    1972-01-01

    Memory and display device uses cathodochromic material to store visual information and fast phosphor to recall information for display and electronic processing. Cathodochromic material changes color when bombarded with electrons, and is restored to its original color when exposed to light of appropiate wavelength.

  11. 77 FR 51606 - Culturally Significant Objects Imported for Exhibition Determinations: “Extravagant Inventions...

    Science.gov (United States)

    2012-08-24

    ... temporary exhibition within the United States, are of cultural significance. The additional objects are... exhibition or display of the additional exhibit objects at The Metropolitan Museum of Art, New York, NY, from... at The Metropolitan Museum of Art, three of the works will continue to be displayed at The...

  12. NCAP projection displays: key issues for commercialization

    Science.gov (United States)

    Tomita, Akira; Jones, Philip J.

    1992-06-01

    Recently there has been much interest in a new polymer nematic dispersion technology, often called as NCAP, PDLC, PNLC, LCPC, etc., since projection displays using this technology have been shown to produce much brighter display images than projectors using conventional twisted nematic (TN) lightvalves. For commercializing projection displays based on this polymer nematic dispersion technology, the new materials must not only meet various electro- optic requirements, e.g., operational voltage, `off-state'' scattering angle, voltage holding ratio and hysteresis, but must also be stable over the lifetime of the product. This paper reports recent progress in the development of NCAP based projection displays and discusses some of the key commercialization issues.

  13. Polyvalent Display of Biomolecules on Live Cells.

    Science.gov (United States)

    Shi, Peng; Zhao, Nan; Lai, Jinping; Coyne, James; Gaddes, Erin R; Wang, Yong

    2018-06-04

    Surface display of biomolecules on live cells offers new opportunities to treat human diseases and perform basic studies. Existing methods are primarily focused on monovalent functionalization, that is, the display of single biomolecules across the cell surface. Here we show that the surface of live cells can be functionalized to display polyvalent biomolecular structures through two-step reactions under physiological conditions. This polyvalent functionalization enables the cell surface to recognize the microenvironment one order of magnitude more effectively than with monovalent functionalization. Thus, polyvalent display of biomolecules on live cells holds great potential for various biological and biomedical applications. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. PENGARUH DISPLAY PRODUK PADA KEPUTUSAN PEMBELIAN KONSUMEN

    Directory of Open Access Journals (Sweden)

    Ina Melati

    2012-11-01

    Full Text Available Most of ritel outlet recently using product display as a one of their best marketing strategy, the reason is quiet easy to be understood, since consumers are too easy to be teased by those kind of beautiful product display that is being displayed by the retail outlet. The good retail outlets are trying their best to design and make the very good product display, so they can attract more consumers and make them not thinking twice to visit their store and purchase lots of thing. Clearly seeing that an attractive product design is able to influence a consumer to make a buying decision. 

  15. A qualitative study of users' engagement with real-time feedback from in-house energy consumption displays

    International Nuclear Information System (INIS)

    Oltra, Christian; Boso, Alex; Espluga, Josep; Prades, Ana

    2013-01-01

    Recent developments in feedback technologies and smart meters have advanced the introduction of energy consumption displays in the home. This could facilitate a significant amount of energy saving for the maximum number of homeowners. But empirical studies show that achieved savings in electricity consumption from in-house displays range approximately from 0 to 20%. In order to qualitatively explore the factors underlying such variation in the achieved saving, this paper studies how a small sample of householders interacted with the feedback from an energy consumption display. Following a heuristic model based on prior energy-related behavioral research, we explore the effects of the in-home display on household electricity. Results indicate that saving might be moderated by the level of user's engagement with the display, preceded by user's motivation to save energy, prior attitudes and, importantly, the level of involvement generated by the intervention. - Highlights: • We explore how householders interact with energy consumption displays. • Users' level of engagement with the display influence achieved savings. • User's motivation, level of involvement and prior attitudes are key elements

  16. Pilot stereotypes for navigation symbols on electronic displays

    Science.gov (United States)

    2006-09-20

    There is currently no common symbology standard for the : electronic display of navigation information. The wide : range of display technologies and the different functions : these displays support make it difficult to design symbols : that are easil...

  17. Perceptual grouping and attention: not all groupings are equal.

    Science.gov (United States)

    Kimchi, Ruth; Razpurker-Apfeld, Irene

    2004-08-01

    We examined grouping under inattention using Driver, Davis, Russell, Turatto, & Freeman's (2001) method. On each trial, two successive displays were briefly presented, each comprising a central target square surrounded by elements. The task was to judge whether the two targets were the same or different. The organization of the background elements stayed the same or changed, independently of the targets. In different conditions, background elements grouped into columns/rows by color similarity, a shape (a triangle/arrow, a square/cross, or a vertical/horizontal line) by color similarity, and a shape with no other elements in the background. We measured the influence of the background on the target same-different judgments. The results imply that background elements grouped into columns/rows by color similarity and into a shape when no segregation from other elements was involved and the shape was relatively "good." In contrast, no background grouping was observed when resolving figure-ground relations for segregated units was required, as in grouping into a shape by color similarity. These results suggest that grouping is a multiplicity of processes that vary in their attentional demands. Regardless of attentional demands, the products of grouping are not available to awareness without attention.

  18. Evaluating Ambient Displays in the Wild

    DEFF Research Database (Denmark)

    Messeter, Jörn; Molenaar, Daryn

    A prominent issue for evaluating ambient displays has been the conflict between the relative intrusiveness of evaluation methods and the intention to keep the display at the periphery of the user’s attention. There is a general lack of research discussing the difficulties of evaluating ambient di...

  19. Research on tactical information display technology for interactive virtual cockpit

    Science.gov (United States)

    Sun, Zhongyun; Tian, Tao; Su, Feng

    2018-04-01

    Based on a fact that traditional tactical information display technology suffers from disadvantages of a large number of data to be transferred and low plotting efficiency in an interactive virtual cockpit, a GID protocol-based simulation has been designed. This method dissolves complex tactical information screens into basic plotting units. The indication of plotting units is controlled via the plotting commands, which solves the incompatibility between the tactical information display in traditional simulation and the desktop-based virtual simulation training system. Having been used in desktop systems for helicopters, fighters, and transporters, this method proves to be scientific and reasonable in design and simple and efficient in usage, which exerts a significant value in establishing aviation equipment technology support training products.

  20. Panoramic, large-screen, 3-D flight display system design

    Science.gov (United States)

    Franklin, Henry; Larson, Brent; Johnson, Michael; Droessler, Justin; Reinhart, William F.

    1995-01-01

    The report documents and summarizes the results of the required evaluations specified in the SOW and the design specifications for the selected display system hardware. Also included are the proposed development plan and schedule as well as the estimated rough order of magnitude (ROM) cost to design, fabricate, and demonstrate a flyable prototype research flight display system. The thrust of the effort was development of a complete understanding of the user/system requirements for a panoramic, collimated, 3-D flyable avionic display system and the translation of the requirements into an acceptable system design for fabrication and demonstration of a prototype display in the early 1997 time frame. Eleven display system design concepts were presented to NASA LaRC during the program, one of which was down-selected to a preferred display system concept. A set of preliminary display requirements was formulated. The state of the art in image source technology, 3-D methods, collimation methods, and interaction methods for a panoramic, 3-D flight display system were reviewed in depth and evaluated. Display technology improvements and risk reductions associated with maturity of the technologies for the preferred display system design concept were identified.

  1. White constancy method for mobile displays

    Science.gov (United States)

    Yum, Ji Young; Park, Hyun Hee; Jang, Seul Ki; Lee, Jae Hyang; Kim, Jong Ho; Yi, Ji Young; Lee, Min Woo

    2014-03-01

    In these days, consumer's needs for image quality of mobile devices are increasing as smartphone is widely used. For example, colors may be perceived differently when displayed contents under different illuminants. Displayed white in incandescent lamp is perceived as bluish, while same content in LED light is perceived as yellowish. When changed in perceived white under illuminant environment, image quality would be degraded. Objective of the proposed white constancy method is restricted to maintain consistent output colors regardless of the illuminants utilized. Human visual experiments are performed to analyze viewers'perceptual constancy. Participants are asked to choose the displayed white in a variety of illuminants. Relationship between the illuminants and the selected colors with white are modeled by mapping function based on the results of human visual experiments. White constancy values for image control are determined on the predesigned functions. Experimental results indicate that propsed method yields better image quality by keeping the display white.

  2. Investigating pointing tasks across angularly coupled display areas

    DEFF Research Database (Denmark)

    Hennecke, Fabian; De Luca, Alexander; Nguyen, Ngo Dieu Huong

    2013-01-01

    Pointing tasks are a crucial part of today’s graphical user interfaces. They are well understood for flat displays and most prominently are modeled through Fitts’ Law. For novel displays (e.g., curved displays with multi-purpose areas), however, it remains unclear whether such models for predicting...... that the target position affects overall pointing speed and offset in both conditions. However, we also found that Fitts’ Law can in fact still be used to predict performance as on flat displays. Our results help designers to optimize user interfaces on angularly coupled displays when pointing tasks are involved....... user performance still hold – in particular when pointing is performed across differently oriented areas. To answer this question, we conducted an experiment on an angularly coupled display – the Curve – with two input conditions: direct touch and indirect mouse pointer. Our findings show...

  3. An inexpensive modification of the laboratory computer display changes emergency physicians' work habits and perceptions.

    Science.gov (United States)

    Marinakis, Harry A; Zwemer, Frank L

    2003-02-01

    Little is known about how the availability of laboratory data affects emergency physicians' practice habits and satisfaction. We modified our clinical information system to display laboratory test status with continuous updates, similar to an airport arrival display. The objective of this study was to determine whether the laboratory test status display altered emergency physicians' work habits and increased satisfaction compared with the time period before implementation of laboratory test status. A retrospective analysis was performed of emergency physicians' actual use of the clinical information system before and after implementation of the laboratory test status display. Emergency physicians were retrospectively surveyed regarding the effect of laboratory test status display on their practice habits and clinical information system use. Survey responses were matched with actual use of the clinical information system. Data were analyzed by using dependent t tests and Pearson correlation coefficients. The study was conducted at a university hospital. Clinical information system use by 46 emergency physicians was analyzed. Twenty-five surveys were returned (71.4% of available emergency physicians). All emergency physicians perceived fewer clinical information system log ons per day after laboratory test status display. The actual average decrease was 19%. Emergency physicians who reported the greatest decrease in log ons per day tended to have the greatest actual decrease (r =-0.36). There was no significant correlation between actual and perceived total time logged on (r =0.08). In regard to effect on emergency physicians' practice habits, 95% reported increased efficiency, 80% reported improved satisfaction with data access, and 65% reported improved communication with patients. An inexpensive computer modification, laboratory test status display, significantly increased subjective efficiency, changed work habits, and improved satisfaction regarding data access

  4. User interface design in safety parameter display systems

    International Nuclear Information System (INIS)

    Schultz, E.E. Jr.; Johnson, G.L.

    1988-01-01

    The extensive installation of computerized safety Parameter Display Systems (SPDSs) in nuclear power plants since the Three-Mile Island accident has enhanced plant safety. It has also raised new issues of how best to ensure an effective interface between human operators and the plant via computer systems. New developments in interface technologies since the current generation of SPDSs was installed can contribute to improving display interfaces. These technologies include new input devices, three-dimensional displays, delay indicators, and auditory displays. Examples of how they might be applied to improve current SPDSs are given. These examples illustrate how the new use interface technology could be applied to future nuclear plant displays

  5. Position display device

    International Nuclear Information System (INIS)

    Nishizawa, Yukio.

    1974-01-01

    Object: To provide a device capable of easily and quickly reading mutual mounting relations of control bodies such as control rods mounted on a nuclear reactor and positions to which the control bodies are driven. Structure: A scanning circuit is provided to scan positions of controllably mounted control bodies such as control rods. Values detected by scanning the positions are converted into character signals according to the values and converted into preranked color signals. The character signals and color signals are stored in a memory circuit by synchronous signals in synchronism with the scanning in the scanning circuit. Outputs of the memory circuit are displayed by a display unit such as a color Braun tube in accordance with the synchronous signals to provide color representations according to positions to which control bodies are driven in the same positional relation as the mounting of the control bodies. (Kamimura, M.)

  6. Effect of freezing method and frozen storage duration on instrumental quality of lamb throughout display.

    Science.gov (United States)

    Muela, E; Sañudo, C; Campo, M M; Medel, I; Beltrán, J A

    2010-04-01

    This study evaluated the effect of freezing method (FM) (air blast freezer, freezing tunnel, or nitrogen chamber) and frozen storage duration (FSD) (1, 3, or 6 months) on the instrumental measurements of quality of thawed lamb, aged for a total of 72 h, throughout a 10-d display period, compared to the quality of fresh meat. pH, colour, lipid oxidation, thawing, and cooking losses in Longissimus thoracis and lumborum muscle, were determined following standard methods. FM affected yellowness, FSD redness and thawing losses, and both affected oxidation (increased as freezing rate decreased and/or as storage duration increased). When compared with fresh meat, the main differences appeared on oxidation (where a significant interaction between treatment (3FM x 3FSD + fresh meat) with display duration was detected), and on total losses (thaw + cook losses). Oxidation was lower in fresh meat, but values were not significantly different from those stored frozen for 1 month. Fresh meat had smaller total losses than did thawed meat, but losses were not significantly different from meat frozen in the freezing tunnel and stored frozen for 1 month. Display duration had a greater effect on instrumental quality parameters than did FM or FSD. pH, b*, and oxidation increased, and L* and a* decreased with an increase in the number of days on display. In conclusion, neither freezing method nor frozen storage up to 6 months influenced extensively the properties of lamb when instrumental measurements of quality were measured in meat that had been displayed for 1d after thawing. The small deterioration shown in this study should not give consumers concerns about frozen meat. 2009 Elsevier Ltd. All rights reserved.

  7. Ocular Tolerance of Contemporary Electronic Display Devices.

    Science.gov (United States)

    Clark, Andrew J; Yang, Paul; Khaderi, Khizer R; Moshfeghi, Andrew A

    2018-05-01

    Electronic displays have become an integral part of life in the developed world since the revolution of mobile computing a decade ago. With the release of multiple consumer-grade virtual reality (VR) and augmented reality (AR) products in the past 2 years utilizing head-mounted displays (HMDs), as well as the development of low-cost, smartphone-based HMDs, the ability to intimately interact with electronic screens is greater than ever. VR/AR HMDs also place the display at much closer ocular proximity than traditional electronic devices while also isolating the user from the ambient environment to create a "closed" system between the user's eyes and the display. Whether the increased interaction with these devices places the user's retina at higher risk of damage is currently unclear. Herein, the authors review the discovery of photochemical damage of the retina from visible light as well as summarize relevant clinical and preclinical data regarding the influence of modern display devices on retinal health. Multiple preclinical studies have been performed with modern light-emitting diode technology demonstrating damage to the retina at modest exposure levels, particularly from blue-light wavelengths. Unfortunately, high-quality in-human studies are lacking, and the small clinical investigations performed to date have failed to keep pace with the rapid evolutions in display technology. Clinical investigations assessing the effect of HMDs on human retinal function are also yet to be performed. From the available data, modern consumer electronic displays do not appear to pose any acute risk to vision with average use; however, future studies with well-defined clinical outcomes and illuminance metrics are needed to better understand the long-term risks of cumulative exposure to electronic displays in general and with "closed" VR/AR HMDs in particular. [Ophthalmic Surg Lasers Imaging Retina. 2018;49:346-354.]. Copyright 2018, SLACK Incorporated.

  8. 27 CFR 6.55 - Display service.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Display service. 6.55 Section 6.55 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS âTIED-HOUSEâ Unlawful Inducements Paying for Advertising, Display Or...

  9. Effects of radiation emitted from visual display terminals on the oral health status

    International Nuclear Information System (INIS)

    Kazem, H.H.

    2008-01-01

    This study was designed to investigate the effects of exposure to radiation emitted from visual display terminals (VDTs) on the oral health status; a cross sectional study was carried out on 100 participants both males and females with age ranging between 22- 40 years working in various places in Cairo. They were divided into two groups; the first consists of 50 subjects working in front of VDTs eight hours min. daily, min. 5 days/ week, 2 years or more, and the other group 50 subjects working away from any VDTs. Both groups were subjected to both oral and dental examinations, including soft tissues assessment by using gingival index (GI) and hard tissues assessment by using decayed, missed, filled (DMF) index. Saliva analysis was done including ph analysis by ph meter cyberscan 500 and trace elements analysis by ion chromatography and salivary immunoglobulin A (sIgA) analysis by ELISA, body temperature by using digital thermometer. The values were compared between both groups and also between before and after exposure in the exposed group. The results demonstrated that the difference in the mean values of either GI or DMF or ph or anions and cations or sIgA levels between exposed and non exposed groups or even between before and after exposure in the exposed group was found to be statistically insignificant. On the other hand there were significant changes in the mean values of body temperature between exposed and non-exposed group and also between before and after exposure in the exposed group. Accordingly, within the limits of this study we can conclude that radiation emitted from VDTs affects body temperature, but do not have any effect on oral health including; hard or soft tissues or salivary components. This might be explained by the radiation with very low energy emitted from VDTs

  10. Effects of radiation emitted from visual display terminals on the oral health status

    Energy Technology Data Exchange (ETDEWEB)

    Kazem, H H [National Center for Radiation Research and Technology, Atomic Energy Authority, Cairo (Egypt)

    2008-07-01

    This study was designed to investigate the effects of exposure to radiation emitted from visual display terminals (VDTs) on the oral health status; a cross sectional study was carried out on 100 participants both males and females with age ranging between 22- 40 years working in various places in Cairo. They were divided into two groups; the first consists of 50 subjects working in front of VDTs eight hours min. daily, min. 5 days/ week, 2 years or more, and the other group 50 subjects working away from any VDTs. Both groups were subjected to both oral and dental examinations, including soft tissues assessment by using gingival index (GI) and hard tissues assessment by using decayed, missed, filled (DMF) index. Saliva analysis was done including ph analysis by ph meter cyberscan 500 and trace elements analysis by ion chromatography and salivary immunoglobulin A (sIgA) analysis by ELISA, body temperature by using digital thermometer. The values were compared between both groups and also between before and after exposure in the exposed group. The results demonstrated that the difference in the mean values of either GI or DMF or ph or anions and cations or sIgA levels between exposed and non exposed groups or even between before and after exposure in the exposed group was found to be statistically insignificant. On the other hand there were significant changes in the mean values of body temperature between exposed and non-exposed group and also between before and after exposure in the exposed group. Accordingly, within the limits of this study we can conclude that radiation emitted from VDTs affects body temperature, but do not have any effect on oral health including; hard or soft tissues or salivary components. This might be explained by the radiation with very low energy emitted from VDTs.

  11. Radon daughters and work at display devices

    International Nuclear Information System (INIS)

    Falk, R.; Nyblom, L.

    1986-01-01

    It has been shown that ions and electrically charged particles in the air can be transported in the electrostatic field between a face and a display device to either the face or the screen. Radon daughters can occur as ions, or sitting on charged particles. This prestudy shows that radon daughters were manifold concentrated on the face of a doll placed in front of a display device, or in a electrostatic field of the kind typical for displaying devices. The radiation dose, in the skin from the radon daughters in an ordinary office environment plus the addition caused by work at a display device, is not strong enough to cause skin damages alone. (BoK)

  12. A display to support knowledge based behavior

    International Nuclear Information System (INIS)

    Lindsay, R.W.

    1990-01-01

    A computerized display has been created for the Experimental Breeder Reactor II (EBR-II) that incorporates information from plant sensors in a thermodynamic model display. The display is designed to provide an operator with an overall view of the plant process as a heat engine. The thermodynamics of the plant are depicted through the use of ionic figures, animated by plant signals, that are related to the major plant components and systems such as the reactor, intermediate heat exchanger, secondary system, evaporators, superheaters, steam system, steam drum, and turbine-generator. This display supports knowledge based reasoning for the operator as well as providing the traditional rule and skill based behavior, and includes side benefits such a inherent signal validation

  13. How to display data by color schemes compatible with red-green color perception deficiencies

    OpenAIRE

    Geissbuehler, Matthias; Lasser, Theo

    2013-01-01

    Visualization of data concerns most scientists. The use of color is required in order to display multidimensional information. In addition, color encoding a univariate image can improve the interpretation significantly. However up to 10% of the adult male population are affected by a red-green color perception deficiency which hampers the correct interpretation and appreciation of color encoded information. This work attempts to give guidelines on how to display a given dataset in a balanced ...

  14. [Comparison of detectability of liquid crystal displays (LCDs) and film using phantoms of small adenocarcinomas as abnormalities].

    Science.gov (United States)

    Mochizuki, Yasuo; Abe, Shinji; Monma, Masahiko; Yamaguchi, Kojirou; Adachi, Toshiki

    2011-01-01

    Following the trend of the digitalization of the modalities used for diagnostic imaging, the devices for such imaging have increasingly included monitors. The present study was undertaken to evaluate the usefulness of soft-copy (liquid crystal display; LCD) images of phantoms of small adenocarcinomas using receiver operating characteristic (ROC) analysis of two different display systems: LCD and hard copy (film). A two-tailed paired t-test and the jackknife method (parametric methods) were performed, and no significant differences were found in the area under the ROC curve (AUC) for the pulmonary fields, lungs, ribs, or mediastinum between the film and LCD display systems, and the detectability did not differ between the film and LCD monitors. A Mann-Whitney U test, which is a non-parametric method that applies to the analysis of a small sample, also showed no significant differences in the AUC. The results of this study suggest that LCDs can replace hard-copy film as a display system if the signals.

  15. View interpolation for medical images on autostereoscopic displays

    NARCIS (Netherlands)

    Zinger, S.; Ruijters, D.; Do, Q.L.; With, de P.H.N.

    2012-01-01

    We present an approach for efficient rendering and transmitting views to a high-resolution autostereoscopic display for medical purposes. Displaying biomedical images on an autostereoscopic display poses different requirements than in a consumer case. For medical usage, it is essential that the

  16. Interactive editing program using display

    International Nuclear Information System (INIS)

    Lang, I.; Ehsenski, J.; Namsraj, Yu.; Fefilov, B.V.

    1976-01-01

    A general description is given as well as principal functions are considered of 'DOSE' interactive editor program with a display involved. The program has been elaborated for TRA/1-1001 computer. This program enables one to edit and correct texts in algorithmical languages on a raster display screen as well as to provide perforated tapes for their further usage. 'DOSE' program is regarded as a basic program system for a set of TRA/1 and MINSK-32 computers

  17. Small - Display Cartography

    DEFF Research Database (Denmark)

    Nissen, Flemming; Hvas, Anders; Münster-Swendsen, Jørgen

    Service Communication and finally, Part IV: Concluding remarks and topics for further research on small-display cartography. Part II includes a separate Appendix D consisting of a cartographic design specification. Part III includes a separate Appendix C consisting of a schema specification, a separate...

  18. Wired World-Wide Web Interactive Remote Event Display

    Energy Technology Data Exchange (ETDEWEB)

    De Groot, Nicolo

    2003-05-07

    WIRED (World-Wide Web Interactive Remote Event Display) is a framework, written in the Java{trademark} language, for building High Energy Physics event displays. An event display based on the WIRED framework enables users of a HEP collaboration to visualize and analyze events remotely using ordinary WWW browsers, on any type of machine. In addition, event displays using WIRED may provide the general public with access to the research of high energy physics. The recent introduction of the object-oriented Java{trademark} language enables the transfer of machine independent code across the Internet, to be safely executed by a Java enhanced WWW browser. We have employed this technology to create a remote event display in WWW. The combined Java-WWW technology hence assures a world wide availability of such an event display, an always up-to-date program and a platform independent implementation, which is easy to use and to install.

  19. Can Attention be Divided Between Perceptual Groups?

    Science.gov (United States)

    McCann, Robert S.; Foyle, David C.; Johnston, James C.; Hart, Sandra G. (Technical Monitor)

    1994-01-01

    Previous work using Head-Up Displays (HUDs) suggests that the visual system parses the HUD and the outside world into distinct perceptual groups, with attention deployed sequentially to first one group and then the other. New experiments show that both groups can be processed in parallel in a divided attention search task, even though subjects have just processed a stimulus in one perceptual group or the other. Implications for models of visual attention will be discussed.

  20. Region 7 Significant Ecological Resource Areas (ECO_RES.SIG_REGIONS)

    Data.gov (United States)

    U.S. Environmental Protection Agency — SIG_REGIONS is a boundary layer that displays Region 7's Significant Ecological Resource Areas. This layer represents large areas within which different ecosystem...

  1. Emotion displays in media: a comparison between American, Romanian, and Turkish children's storybooks.

    Science.gov (United States)

    Wege, Briana Vander; Sánchez González, Mayra L; Friedlmeier, Wolfgang; Mihalca, Linda M; Goodrich, Erica; Corapci, Feyza

    2014-01-01

    Children's books may provide an important resource of culturally appropriate emotions. This study investigates emotion displays in children's storybooks for preschoolers from Romania, Turkey, and the US in order to analyze cultural norms of emotions. We derived some hypotheses by referring to cross-cultural studies about emotion and emotion socialization. For such media analyses, the frequency rate of certain emotion displays can be seen as an indicator for the salience of the specific emotion. We expected that all children's storybooks would highlight dominantly positive emotions and that US children's storybooks would display negative powerful emotions (e.g., anger) more often and negative powerless emotions (e.g., sadness) less often than Turkish and Romanian storybooks. We also predicted that the positive and negative powerful emotion expressions would be more intense in the US storybooks compared to the other storybooks. Finally, we expected that social context (ingroup/outgroup) may affect the intensity emotion displays more in Turkish and Romanian storybooks compared to US storybooks. Illustrations in 30 popular children's storybooks (10 for each cultural group) were coded. Results mostly confirmed the hypotheses but also pointed to differences between Romanian and Turkish storybooks. Overall, the study supports the conclusion that culture-specific emotion norms are reflected in media to which young children are exposed.

  2. Emotion displays in media: a comparison between American, Romanian, and Turkish children's storybooks

    Science.gov (United States)

    Wege, Briana Vander; Sánchez González, Mayra L.; Friedlmeier, Wolfgang; Mihalca, Linda M.; Goodrich, Erica; Corapci, Feyza

    2014-01-01

    Children's books may provide an important resource of culturally appropriate emotions. This study investigates emotion displays in children's storybooks for preschoolers from Romania, Turkey, and the US in order to analyze cultural norms of emotions. We derived some hypotheses by referring to cross-cultural studies about emotion and emotion socialization. For such media analyses, the frequency rate of certain emotion displays can be seen as an indicator for the salience of the specific emotion. We expected that all children's storybooks would highlight dominantly positive emotions and that US children's storybooks would display negative powerful emotions (e.g., anger) more often and negative powerless emotions (e.g., sadness) less often than Turkish and Romanian storybooks. We also predicted that the positive and negative powerful emotion expressions would be more intense in the US storybooks compared to the other storybooks. Finally, we expected that social context (ingroup/outgroup) may affect the intensity emotion displays more in Turkish and Romanian storybooks compared to US storybooks. Illustrations in 30 popular children's storybooks (10 for each cultural group) were coded. Results mostly confirmed the hypotheses but also pointed to differences between Romanian and Turkish storybooks. Overall, the study supports the conclusion that culture-specific emotion norms are reflected in media to which young children are exposed. PMID:24987384

  3. Optimizing direct response in Internet display advertising

    OpenAIRE

    Aksakallı, Vural

    2013-01-01

    Internet display advertising has grown into a multi-billion dollar a year global industry and direct response campaigns account for about three-quarters of all Internet display advertising. In such campaigns, advertisers reach out to a target audience via some form of a visual advertisement (hereinafter also called “ad”) to maximize short-term sales revenue. In this study, we formulate an advertiser’s revenue maximization problem in direct response Internet display advertisement campaigns as ...

  4. Online Display Advertising Causal Attribution and Evaluation

    OpenAIRE

    Barajas Zamora, Joel

    2015-01-01

    The allocation of a given budget to online display advertising as a marketing channel has motivated the development of statistical methods to measure its effectiveness. Recent studies show that display advertising often triggers online users to search for more information on products. Eventually, many of these users convert at the advertiser’s website. A key challenge is to measure the effectiveness of display advertising when users are exposed to multiple unknown advertising channels.We deve...

  5. Impact on smoking of England's 2012 partial tobacco point of sale display ban: a repeated cross-sectional national study.

    Science.gov (United States)

    Kuipers, Mirte A G; Beard, Emma; Hitchman, Sara C; Brown, Jamie; Stronks, Karien; Kunst, Anton E; McNeill, Ann; West, Robert

    2017-03-01

    A partial tobacco point of sale (PoS) display ban was introduced in large shops (>280 m 2 floor area) in England on 6 April 2012. The aim of this study was to assess the medium-term effects of the partial tobacco PoS display ban on smoking in England. Data were used from 129 957 respondents participating in monthly, cross-sectional household surveys of representative samples of the English adult population aged 18+ years from January 2009 to February 2015. Interrupted-time series regression models assessed step changes in the level of current smoking and cigarette consumption in smokers and changes in the trends postban compared with preban. Models were adjusted for sociodemographic variables and e-cigarette use, seasonality and autocorrelation. Potential confounding by cigarette price was accounted for by time, as price was almost perfectly correlated with time. Following the display ban, there was no immediate step level change in smoking (-3.69% change, 95% CI -7.94 to 0.75, p=0.102) or in cigarette consumption (β -0.183, 95% CI -0.602 to 0.236). There was a significantly steeper decline in smoking post display ban (-0.46% change, 95% CI -0.72 to -0.20, p=0.001). This effect was demonstrated by respondents in manual occupations (-0.62% change, 95% CI -0.72 to -0.20, p=0.001), but not for those in non-manual occupations (-0.42, 95% CI -0.90 to 0.06, p=0.084). Cigarette consumption declined preban period (β -0.486, 95% CI -0.633 to -0.339, p<0.001), but no significant change in cigarette consumption trend was observed (β 0.019, 95% CI -0.006 to 0.042, p=0.131). The partial tobacco PoS display ban introduced in England in April 2012 did not lead to an immediate decline in smoking, but was followed by a decline in the trend of smoking prevalence that could not be accounted for by seasonal factors, e-cigarette use or price changes. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  6. Methods and apparatus for transparent display using scattering nanoparticles

    Science.gov (United States)

    Hsu, Chia Wei; Qiu, Wenjun; Zhen, Bo; Shapira, Ofer; Soljacic, Marin

    2016-05-10

    Transparent displays enable many useful applications, including heads-up displays for cars and aircraft as well as displays on eyeglasses and glass windows. Unfortunately, transparent displays made of organic light-emitting diodes are typically expensive and opaque. Heads-up displays often require fixed light sources and have limited viewing angles. And transparent displays that use frequency conversion are typically energy inefficient. Conversely, the present transparent displays operate by scattering visible light from resonant nanoparticles with narrowband scattering cross sections and small absorption cross sections. More specifically, projecting an image onto a transparent screen doped with nanoparticles that selectively scatter light at the image wavelength(s) yields an image on the screen visible to an observer. Because the nanoparticles scatter light at only certain wavelengths, the screen is practically transparent under ambient light. Exemplary transparent scattering displays can be simple, inexpensive, scalable to large sizes, viewable over wide angular ranges, energy efficient, and transparent simultaneously.

  7. Array display tool ADT reference manual. Version 1.2

    International Nuclear Information System (INIS)

    Evans, K. Jr.

    1995-12-01

    Array Display Tool (ADT) is a Motif program to display arrays of process variables from the Advanced Photon Source control system. A typical use is to display the horizontal and vertical monitor readings. A picture of the ADT interface is here. The screen layout, apart from the menu bar, consists of two types of graphic areas in which the values for the arrays of process variables are shown: Display areas, which display one or more arrays as a function of index, and a zoom area. In the zoom area specified arrays only are displayed as a function of lattice position along with symbols for the major elements of the lattice. There can be several display areas, but at most one zoom area. When the screen is resized these areas change size proportionally. There are a number of options in the View Menu to change the way the values are displayed. It is also possible via the Options Menu to: (1) Store the current values internally. (2) Store the values from a snapshot file internally. (3) Display one of the stored sets of values along with the current values. (4) Display the difference of the current values with one of the stored sets of values. (5) Write the current values to a snapshot file. There are several (currently 5) slots in which you can store values internally. In addition you can display the values with specified reference values subtracted

  8. Pervasive displays understanding the future of digital signage

    CERN Document Server

    Davies, Nigel; Alt, Florian

    2014-01-01

    Fueled by falling display hardware costs and rising demand, digital signage and pervasive displays are becoming ever more ubiquitous. Such systems have traditionally been used for advertising and information dissemination, with digital signage commonplace in shopping malls, airports and public spaces. While advertising and broadcasting announcements remain important applications, developments in sensing and interaction technologies are enabling entirely new classes of display applications that tailor content to the situation and audience of the display. As a result, signage systems are beginni

  9. Securing information display by use of visual cryptography.

    Science.gov (United States)

    Yamamoto, Hirotsugu; Hayasaki, Yoshio; Nishida, Nobuo

    2003-09-01

    We propose a secure display technique based on visual cryptography. The proposed technique ensures the security of visual information. The display employs a decoding mask based on visual cryptography. Without the decoding mask, the displayed information cannot be viewed. The viewing zone is limited by the decoding mask so that only one person can view the information. We have developed a set of encryption codes to maintain the designed viewing zone and have demonstrated a display that provides a limited viewing zone.

  10. The impact of structured support groups for pregnant South African women recently diagnosed HIV positive.

    Science.gov (United States)

    Mundell, Jonathan P; Visser, Maretha J; Makin, Jennifer D; Kershaw, Trace S; Forsyth, Brian W C; Jeffery, Bridget; Sikkema, Kathleen J

    2011-08-31

    The authors of this study evaluated a structured 10-session psychosocial support group intervention for newly HIV-diagnosed pregnant South African women. Participants were expected to display increases in HIV disclosure, self-esteem, active coping and positive social support, and decreases in depression, avoidant coping, and negative social support. Three hundred sixty-one pregnant HIV-infected women were recruited from four antenatal clinics in Tshwane townships from April 2005 to September 2006. Using a quasi-experimental design, assessments were conducted at baseline and two and eight months post-intervention. A series of random effects regression analyses were conducted, with the three assessment points treated as a random effect of time. At both follow-ups, the rate of disclosure in the intervention group was significantly higher than that of the comparison group (p<0.001). Compared to the comparison group at the first follow-up, the intervention group displayed higher levels of active coping (t=2.68, p<0.05) and lower levels of avoidant coping (t=-2.02, p<0.05), and those who attended at least half of the intervention sessions exhibited improved self-esteem (t=2.11, p<0.05). Group interventions tailored for newly HIV positive pregnant women, implemented in resource-limited settings, may accelerate the process of adjusting to one's HIV status, but may not have sustainable benefits over time.

  11. Assessing display variability in wild brown anoles Anolis sagrei using a mechanical lizard model

    Directory of Open Access Journals (Sweden)

    Sarah R. PARTAN, Peter OTOVIC, Virginia L. PRICE, Scott E. BROWN

    2011-04-01

    Full Text Available Signals used for species identity ought to be highly stereotyped so as to facilitate immediate recognition by conspecifics. It is surprising therefore to find variability in putative species signature displays. The brown anole Anolis sagrei has a high degree of variability in its signature bobbing display. In this study we collected descriptive data on variability in the temporal structure of wild brown anole bobbing patterns, finding that no two displays analyzed had the same temporal structure, and we also tested whether wild brown anoles prefer the signature display over an alternate display pattern by using mechanical robot playbacks in the field. As a response metric we assessed whether or not the lizards showed social responses (pushup, dewlap extension, or head-nod in response to the robotic presentations. We found that the lizards responded slightly more to the signature than to the alternate pattern, providing support for the idea that despite the variability seen in displays, the signature pattern is meaningful to them. We tested two other independent variables: speed of the display and elevation of the robot during its display, neither of which was significant. Dewlap extensions were given predominantly by adult males and were more likely to be given in the breeding season than the nonbreeding season. Pushups and head-nods were given equally by males and a combined class of females and juveniles, and were not seasonal. Head-nods increased after the robot turned off, suggesting that they may be used in a conversational turn-taking style during communication [Current Zoology 57 (2: 140–152, 2011].

  12. Unit information system operational displays for VVER-1000 reactors

    International Nuclear Information System (INIS)

    Anikanov, S.S.; Carrera, J.P.; Gordon, P.

    1997-01-01

    The role of high level operational displays is explained as well as the principles of the design of such displays. The tasks of WWER operating personnel are described and the support provided by operational displays is highlighted. The architecture of the displays is also dealt with. (A.K.)

  13. Integration of real-time 3D capture, reconstruction, and light-field display

    Science.gov (United States)

    Zhang, Zhaoxing; Geng, Zheng; Li, Tuotuo; Pei, Renjing; Liu, Yongchun; Zhang, Xiao

    2015-03-01

    Effective integration of 3D acquisition, reconstruction (modeling) and display technologies into a seamless systems provides augmented experience of visualizing and analyzing real objects and scenes with realistic 3D sensation. Applications can be found in medical imaging, gaming, virtual or augmented reality and hybrid simulations. Although 3D acquisition, reconstruction, and display technologies have gained significant momentum in recent years, there seems a lack of attention on synergistically combining these components into a "end-to-end" 3D visualization system. We designed, built and tested an integrated 3D visualization system that is able to capture in real-time 3D light-field images, perform 3D reconstruction to build 3D model of the objects, and display the 3D model on a large autostereoscopic screen. In this article, we will present our system architecture and component designs, hardware/software implementations, and experimental results. We will elaborate on our recent progress on sparse camera array light-field 3D acquisition, real-time dense 3D reconstruction, and autostereoscopic multi-view 3D display. A prototype is finally presented with test results to illustrate the effectiveness of our proposed integrated 3D visualization system.

  14. Instrument-mounted displays for reducing cognitive load during surgical navigation.

    Science.gov (United States)

    Herrlich, Marc; Tavakol, Parnian; Black, David; Wenig, Dirk; Rieder, Christian; Malaka, Rainer; Kikinis, Ron

    2017-09-01

    Surgical navigation systems rely on a monitor placed in the operating room to relay information. Optimal monitor placement can be challenging in crowded rooms, and it is often not possible to place the monitor directly beside the situs. The operator must split attention between the navigation system and the situs. We present an approach for needle-based interventions to provide navigational feedback directly on the instrument and close to the situs by mounting a small display onto the needle. By mounting a small and lightweight smartwatch display directly onto the instrument, we are able to provide navigational guidance close to the situs and directly in the operator's field of view, thereby reducing the need to switch the focus of view between the situs and the navigation system. We devise a specific variant of the established crosshair metaphor suitable for the very limited screen space. We conduct an empirical user study comparing our approach to using a monitor and a combination of both. Results from the empirical user study show significant benefits for cognitive load, user preference, and general usability for the instrument-mounted display, while achieving the same level of performance in terms of time and accuracy compared to using a monitor. We successfully demonstrate the feasibility of our approach and potential benefits. With ongoing technological advancements, instrument-mounted displays might complement standard monitor setups for surgical navigation in order to lower cognitive demands and for improved usability of such systems.

  15. A display to support knowledge based behavior

    International Nuclear Information System (INIS)

    Lindsay, R.W.

    1990-01-01

    This paper reports on a computerized display that has been created for the Experimental Breeder Reactor II that incorporates information from plant sensors in a thermodynamic model display. The display is designed to provide an operator with an overall view of the plant process as a heat engine. The thermodynamics of the plant are depicted through the use of iconic figures, animated by plant signals, that are related to the major plant components and systems such as the reactor, intermediate heat exchanger, secondary system, evaporators, superheaters, steam system, steam drum, and turbine-generator. This display supports knowledge based reasoning for the operator as well as providing data for the traditional rule and skill based behavior, and includes side benefits such as inherent signal validation

  16. Effects of Diquafosol Ophthalmic Solution on Quality of Life in Dry Eye Assessed Using the Dry Eye-Related Quality-of-Life Score Questionnaire: Effectiveness in Patients While Reading and Using Visual Display Terminals.

    Science.gov (United States)

    Utsunomiya, Tsugiaki; Kawahara, Atsushi; Hanada, Kazuomi; Yoshida, Akitoshi

    2017-08-01

    Diquafosol ophthalmic solution improves objective findings in the ocular surface and subjective symptoms in patients with dry eye. The Dry Eye-Related Quality-of-Life Score (DEQS) questionnaire was developed to assess dry eye symptoms and their effects on quality of life. However, because little research using the DEQS has been reported, we evaluated the effects of diquafosol ophthalmic solution on ocular surface findings and quality of life using the DEQS in patients with dry eye. Sixty-three patients with dry eye were assigned to the control group (artificial tears) or diquafosol group. Both groups instilled 1 drop of the solution in both eyes 6 times daily and were evaluated after 2 weeks; the diquafosol group also was instructed to be examined at 1 and 3 months. We evaluated the subjective symptoms using the DEQS, fluorescein staining score, tear film breakup time (BUT), Schirmer testing, and lower tear meniscus height with anterior-segment optical coherence tomography. In the diquafosol group, the fluorescein staining score, BUT, tear meniscus height, and DEQS scores improved significantly compared with before treatment in contrast to the control group. Furthermore, in the diquafosol group, the staining score and BUT improved significantly compared with the control group. Analysis of each DEQS item indicated that diquafosol ophthalmic solution relieved foreign body sensation and problems when reading and using visual display terminals compared with the control group. Diquafosol ophthalmic solution was effective in patients with dry eye, especially those with foreign body sensation and problems when reading and using visual display terminals.

  17. DiGIR1 and NaGIR1: naturally occurring group I-like ribozymes with unique core organization and evolved biological role

    DEFF Research Database (Denmark)

    Johansen, Steinar; Einvik, Christer; Nielsen, Henrik

    2002-01-01

    introns (twin-ribozyme introns) in distantly related organisms. The Didymium GIR1 (DiGIR1) and Naegleria GIR1 (NaGIR1) share fundamental features in structural organization and reactivity, and display significant differences when compared to the related group I splicing ribozymes. GIR1 lacks...

  18. A programmable display layer for virtual reality system architectures.

    Science.gov (United States)

    Smit, Ferdi Alexander; van Liere, Robert; Froehlich, Bernd

    2010-01-01

    Display systems typically operate at a minimum rate of 60 Hz. However, existing VR-architectures generally produce application updates at a lower rate. Consequently, the display is not updated by the application every display frame. This causes a number of undesirable perceptual artifacts. We describe an architecture that provides a programmable display layer (PDL) in order to generate updated display frames. This replaces the default display behavior of repeating application frames until an update is available. We will show three benefits of the architecture typical to VR. First, smooth motion is provided by generating intermediate display frames by per-pixel depth-image warping using 3D motion fields. Smooth motion eliminates various perceptual artifacts due to judder. Second, we implement fine-grained latency reduction at the display frame level using a synchronized prediction of simulation objects and the viewpoint. This improves the average quality and consistency of latency reduction. Third, a crosstalk reduction algorithm for consecutive display frames is implemented, which improves the quality of stereoscopic images. To evaluate the architecture, we compare image quality and latency to that of a classic level-of-detail approach.

  19. Comparing the effectiveness of different displays in enhancing illusions of self-movement (vection

    Directory of Open Access Journals (Sweden)

    Bernhard E. Riecke

    2015-06-01

    Full Text Available Illusions of self-movement (vection can be used in Virtual Reality (VR and other applications to give users the embodied sensation that they are moving when physical movement is unfeasible or too costly. Whereas a large body of vection literature studied how various parameters of the presented visual stimulus affect vection, little is known how different display types might affect vection. As a step towards addressing this gap, we conducted three experiments to compare vection and usability parameters between commonly used VR displays, ranging from stereoscopic projection and 3D TV to high-end head-mounted display (HMD, NVIS SX111 and recent low-cost HMD (Oculus Rift. The last experiment also compared these two HMDs in their native full field of view FOV and a reduced, matched FOV of 72×45°. Participants moved along linear and curvilinear paths in the virtual environment, reported vection onset time, and rated vection intensity at the end of each trial. In addition, user ratings on immersion, motion sickness, vection, and overall preference were recorded retrospectively and compared between displays. Unexpectedly, there were no significant effects of display on vection measures. Reducing the FOV for the HMDs (from full to 72×45° decreased vection onset latencies, but did not affect vection intensity. As predicted, curvilinear paths yielded earlier and more intense vection. Although vection has often been proposed to predict or even cause motion sickness, we observed no correlation for any of the displays studied. In conclusion, perceived self-motion and other user experience measures proved surprisingly tolerant towards changes in display type as long as the FOV was roughly matched. This suggests that display choice for vection research and VR applications can be largely based on other considerations as long as the provided FOV is sufficiently large.

  20. A polymorphic variant in the human electron transfer flavoprotein alpha-chain (alpha-T171) displays decreased thermal stability and is overrepresented in very-long-chain acyl-CoA dehydrogenase-deficient patients with mild childhood presentation

    DEFF Research Database (Denmark)

    Bross, P; Pedersen, P; Nyholm, M

    1999-01-01

    The consequences of two amino acid polymorphisms of human electron transfer flavoprotein (alpha-T/I171 in the alpha-subunit and beta-M/T154 in the beta-subunit) on the thermal stability of the enzyme are described. The alpha-T171 variant displayed a significantly decreased thermal stability, wher....... This is compatible with a negative modulating effect of the less-stable alpha-T171 ETF variant in this group of VLCAD patients that harbor missense mutations in at least one allele and therefore potentially display residual levels of VLCAD enzyme activity. Udgivelsesdato: 1999-Jun...

  1. An Advanced Diagnostic Display for Core Protection Calculator System

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji-Hyeon; Jeong, See-Chae; Sohn, Se-Do [Korea Power Engineering Company, Daejeon (Korea, Republic of)

    2008-10-15

    The main purpose of a Nuclear Power Plant Instrumentation and Control (I and C) Display System is to provide operator's interface for I and C systems. The CPCS display(Shin-Kori 1 and 2) provides operators with 1) plant monitoring values of field input and algorithm variables that reflect the reactor core conditions, 2) operation values that operators can change and 3) CPCS status. It will be an optimal case if operators can understand the plant (including CPCS itself) condition intuitively with the displayed values but it is not easy in CPCS. For example, if the CPCS Channel Trouble light is lit, operators need some amount of time to investigate what caused the trouble light because there are more than hundred causes that can generate the channel trouble. If a Display supports diagnostic information that shows what cause the displayed alarms, it will greatly help operators in easy understanding the CPCS status. To provide these diagnostic information, this paper suggests an active self-explanatory display mechanism. This self-explanatory diagnostic display mechanism utilizes an ontology in XML that describes parent child, sibling relationships of display variables, through which in-depth, in-breadth diagnostic tracking is possible. This paper consists of two parts. First, the key features of CPCS Flat Panel Display System (FPDS) are described. Second, the features of active self explanatory diagnostic display are discussed.

  2. An Advanced Diagnostic Display for Core Protection Calculator System

    International Nuclear Information System (INIS)

    Kim, Ji-Hyeon; Jeong, See-Chae; Sohn, Se-Do

    2008-01-01

    The main purpose of a Nuclear Power Plant Instrumentation and Control (I and C) Display System is to provide operator's interface for I and C systems. The CPCS display(Shin-Kori 1 and 2) provides operators with 1) plant monitoring values of field input and algorithm variables that reflect the reactor core conditions, 2) operation values that operators can change and 3) CPCS status. It will be an optimal case if operators can understand the plant (including CPCS itself) condition intuitively with the displayed values but it is not easy in CPCS. For example, if the CPCS Channel Trouble light is lit, operators need some amount of time to investigate what caused the trouble light because there are more than hundred causes that can generate the channel trouble. If a Display supports diagnostic information that shows what cause the displayed alarms, it will greatly help operators in easy understanding the CPCS status. To provide these diagnostic information, this paper suggests an active self-explanatory display mechanism. This self-explanatory diagnostic display mechanism utilizes an ontology in XML that describes parent child, sibling relationships of display variables, through which in-depth, in-breadth diagnostic tracking is possible. This paper consists of two parts. First, the key features of CPCS Flat Panel Display System (FPDS) are described. Second, the features of active self explanatory diagnostic display are discussed

  3. T-38 Primary Flight Display Prototyping and HIVE Support Abstract & Summary

    Science.gov (United States)

    Boniface, Andrew

    2015-01-01

    . Complete navigation, control, and function customization will be achievable once a display is fully developed. Other than the T-38 prototyping, I spent time learning how to design small circuits and write code for them to function. This was done by adding electronic circuit components to breadboard and microcontroller then writing code to speak to those components through the microcontroller. I went through an Arduino starter kit to build circuits and code software that allowed the hardware to act. This work was planned to assist in a lighting project this fall but another solution was discovered for the lighting project. Other tasks that I assisted with, included hands on work such as mock-up construction/removal, logic analyzer repairs, and soldering with circuits. The unique opportunity to be involved work with NASA has significantly changed my educational and career goals. This opportunity has only opened the door to my career with engineering. I have learned over the span of this internship that I am fascinated by the type of work that NASA does. My desire to work in the aerospace industry has increased immensely. I hope to return to NASA to be more involved in the advancement of science, engineering, and spaceflight. My interests for my future education and career lie in NASA’s work - pioneering the future in space exploration, scientific discovery and aeronautics research.

  4. Automatic adjustment of display window (gray-level condition) for MR images using neural networks

    International Nuclear Information System (INIS)

    Ohhashi, Akinami; Nambu, Kyojiro.

    1992-01-01

    We have developed a system to automatically adjust the display window width and level (WWL) for MR images using neural networks. There were three main points in the development of our system as follows: 1) We defined an index for the clarity of a displayed image, and called 'EW'. EW is a quantitative measure of the clarity of an image displayed in a certain WWL, and can be derived from the difference between gray-level with the WWL adjusted by a human expert and with a certain WWL. 2) We extracted a group of six features from a gray-level histogram of a displayed image. We designed two neural networks which are able to learn the relationship between these features and the desired output (teaching signal), 'EQ', which is normalized to 0 to 1.0 from EW. Two neural networks were used to share the patterns to be learned; one learns a variety of patterns with less accuracy, and the other learns similar patterns with accuracy. Learning was performed using a back-propagation method. As a result, the neural networks after learning are able to provide a quantitative measure, 'Q', of the clarity of images displayed in the designated WWL. 3) Using the 'Hill climbing' method, we have been able to determine the best possible WWL for a displaying image. We have tested this technique for MR brain images. The results show that this system can adjust WWL comparable to that adjusted by a human expert for the majority of test images. The neural network is effective for the automatic adjustment of the display window for MR images. We are now studying the application of this method to MR images of another regions. (author)

  5. Function-oriented display system: background and first prototypes

    International Nuclear Information System (INIS)

    Andresen, Gisle; Friberg, Maarten; Teigen, Arild; Pirus, Dominique

    2004-04-01

    The objective of the function-oriented displays and alarm project is to design, implement and evaluate Human System Interfaces (HSI) based on a function-oriented design philosophy. Function-oriented design is an approach for designing HSIs where the plant's functions, identified through a function analysis, are used for determining the content, organisation, and management of displays. The project has used the 'FITNESS approach', originally developed by EDF in France, as a starting point. FITNESS provides an integrated display system consisting of process operating displays, operating procedures, alarms and trend displays - all based on a functional decomposition of the plant. So far, two prototypes have been implemented on the FRESH PWR simulator in HAMMLAB. The first prototype focused on the condensate pumps. Three process operating displays representing functions at different levels of the functional hierarchy were implemented. Computerised startup and shutdown procedures for the condensate pumps function were also implemented. In the second prototype, the scope was increased to cover the main feedwater system. The displays of the first prototype were redesigned and additional displays were created. In conclusion, the first phase of the project has been completed successfully, and we are now ready to enter the second phase. In the second phase, the scope of the prototype will be increased further to include the steam-generators and function-oriented disturbance operating procedures. The prototype will be evaluated in a user test conducted later in 2004. (Author)

  6. Scanning fiber microdisplay: design, implementation, and comparison to MEMS mirror-based scanning displays.

    Science.gov (United States)

    Khayatzadeh, Ramin; Civitci, Fehmi; Ferhanoglu, Onur; Urey, Hakan

    2018-03-05

    In this study, we propose a compact, lightweight scanning fiber microdisplay towards virtual and augmented reality applications. Our design that is tailored as a head-worn-display simply consists of a four-quadrant piezoelectric tube actuator through which a fiber optics cable is extended and actuated, and a reflective (or semi-reflective) ellipsoidal surface that relays the moving tip of the fiber onto the viewer's retina. The proposed display, offers significant advantages in terms of architectural simplicity, form-factor, fabrication complexity and cost over other fiber scanner and MEMS mirror counterparts towards practical realization. We demonstrate the display of various patterns with ∼VGA resolution and further provide analytical formulas for mechanical and optical constraints to compare the performance of the proposed scanning fiber microdisplay with that of MEMS mirror-based microdisplays. Also we discuss the road steps towards improving the performance of the proposed scanning fiber microdisplay to high-definition video formats (such as HD1440), which is beyond what has been achieved by MEMS mirror based laser scanning displays.

  7. Reflective and transflective liquid crystal displays

    Science.gov (United States)

    Zhou, Fushan

    Recently transflective liquid crystal displays (LCD) received a lot of attention. A transflective display has a transmissive mode and a reflective mode. It combines the high contrast, high brightness of the transmissive mode with energy-saving of reflective mode and has good performance in various illumination conditions. However, state-of-the-art transflective displays have problems such as different electro-optical properties, difficulty in compatibility and optimization of both modes, low efficiency of light utilization, and complexity in structure. This dissertation focuses on finding new designs of transflective displays that address those problems. One way to do this is to study film compensation of LCD. We first studied film compensation of bistable twisted nematic (BTN) LCD. Starting form the reduced (3x3) Mueller matrices, we derived and simplified the conditions that film compensated BTN can be optimized. Based on these relations, electro-optical properties of some particular configurations, and designs of transflective BTN with high brightness and contrast were given. To confirm and get a better understanding of the results, we use the Poincare sphere to analyze film compensated BTN. The key to this approach is the existence of "fixed points". Compared with the matrix approach, this approach is more simple, elegant, and efficient. We then generalized the Poincare sphere approach to a universal approach of LCD. We applied the universal approach to film compensation of ECB and IPS, and the design of achromatic birefringent filters. We also give two more new designs of transflective displays. In the first design, a dichroic mirror is used to split the visible spectrum into two parts used in transmissive and reflective modes, respectively. Both modes can be optimized. It has a simple structure and good light utilization. A design for a full-color transflective display with good performance is also given. In the second design, each pixel is divided into two

  8. Parochial cooperation in nested intergroup dilemmas is reduced when it harms out-groups.

    Science.gov (United States)

    Aaldering, Hillie; Ten Velden, Femke S; van Kleef, Gerben A; De Dreu, Carsten K W

    2018-06-01

    In intergroup settings, humans often contribute to their in-group at a personal cost. Such parochial cooperation benefits the in-group and creates and fuels intergroup conflict when it simultaneously hurts out-groups. Here, we introduce a new game paradigm in which individuals can display universal cooperation (which benefits both in- and out-group) as well as parochial cooperation that does, versus does not hurt the out-group. Using this set-up, we test hypotheses derived from group selection theory, social identity, and bounded generalized reciprocity theory. Across three experiments we find, first, that individuals choose parochial over universal cooperation. Second, there was no evidence for a motive to maximize differences between in- and out-group, which is central to both group selection and social identity theory. However, fitting bounded generalized reciprocity theory, we find that individuals with a prosocial value orientation display parochial cooperation, provided that this does not harm the out-group; individualists, in contrast, display parochialism whether or not nut it hurts the out-group. Our findings were insensitive to cognitive taxation (Experiments 2-3), and emerged even when universal cooperation served social welfare more than parochialism (Experiment 3). (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  9. A kinesthetic-tactual display for stall deterrence

    Science.gov (United States)

    Gilson, R. D.; Ventola, R. W.; Fenton, R. E.

    1975-01-01

    A kinesthetic tactual display may be effectively used as a control aid per previous flight tests. Angle of attack information would be continuously presented to a pilot, via this display, during critical operational phases where stalls are probable. A two phase plan for evaluating this concept is presented. A first development phase would encompass: (1) display fabrication for a conventional control yoke; (2) its installation, together with other necessary instrumentation, in an experimental aircraft; and (3) preliminary flight testing by experienced pilots.

  10. Illuminant-adaptive color reproduction for mobile display

    Science.gov (United States)

    Kim, Jong-Man; Park, Kee-Hyon; Kwon, Oh-Seol; Cho, Yang-Ho; Ha, Yeong-Ho

    2006-01-01

    This paper proposes an illuminant-adaptive reproduction method using light adaptation and flare conditions for a mobile display. Mobile displays, such as PDAs and cellular phones, are viewed under various lighting conditions. In particular, images displayed in daylight are perceived as quite dark due to the light adaptation of the human visual system, as the luminance of a mobile display is considerably lower than that of an outdoor environment. In addition, flare phenomena decrease the color gamut of a mobile display by increasing the luminance of dark areas and de-saturating the chroma. Therefore, this paper presents an enhancement method composed of lightness enhancement and chroma compensation. First, the ambient light intensity is measured using a lux-sensor, then the flare is calculated based on the reflection ratio of the display device and the ambient light intensity. The relative cone response is nonlinear to the input luminance. This is also changed by the ambient light intensity. Thus, to improve the perceived image, the displayed luminance is enhanced by lightness linearization. In this paper, the image's luminance is transformed by linearization of the response to the input luminance according to the ambient light intensity. Next, the displayed image is compensated according to the physically reduced chroma, resulting from flare phenomena. The reduced chroma value is calculated according to the flare for each intensity. The chroma compensation method to maintain the original image's chroma is applied differently for each hue plane, as the flare affects each hue plane differently. At this time, the enhanced chroma also considers the gamut boundary. Based on experimental observations, the outer luminance-intensity generally ranges from 1,000 lux to 30,000 lux. Thus, in the case of an outdoor environment, i.e. greater than 1,000 lux, this study presents a color reproduction method based on an inverse cone response curve and flare condition. Consequently

  11. Improvements in or relating to information display arrangements

    International Nuclear Information System (INIS)

    Blay, A.G.

    1975-01-01

    An information display arrangement for use in biomedical radiography with either X- or γ-radiation or ultrasonic waves is described. This invention overcomes the drawbacks of conventional three-dimensional displays where certain features may be partially or completely obscured from view by matter which is not of interest. This improvement is achieved by interactive means using a light pen on a cathode ray tube display to effectively draw boundaries between relevant and irrelevant features. The computerised display is then up-dated from the information store containing the transmission data. (U.K.)

  12. Visual Attention to Radar Displays

    Science.gov (United States)

    Moray, N.; Richards, M.; Brophy, C.

    1984-01-01

    A model is described which predicts the allocation of attention to the features of a radar display. It uses the growth of uncertainty and the probability of near collision to call the eye to a feature of the display. The main source of uncertainty is forgetting following a fixation, which is modelled as a two dimensional diffusion process. The model was used to predict information overload in intercept controllers, and preliminary validation obtained by recording eye movements of intercept controllers in simulated and live (practice) interception.

  13. Self-assembling electroactive hydrogels for flexible display technology

    Energy Technology Data Exchange (ETDEWEB)

    Jones, Scott L; Wong, Kok Hou; Ladouceur, Francois [School of Electrical Engineering and Telecommunications, University of NSW, Sydney, NSW, 2052 (Australia); Thordarson, Pall, E-mail: f.ladouceur@unsw.edu.a [School of Chemistry, University of NSW, Sydney, NSW, 2052 (Australia)

    2010-12-15

    We have assessed the potential of self-assembling hydrogels for use in conformal displays. The self-assembling process can be used to alter the transparency of the material to all visible light due to scattering by fibres. The reversible transition is shown to be of low energy by differential scanning calorimetry. For use in technology it is imperative that this transition is controlled electrically. We have thus synthesized novel self-assembling hydrogelator molecules which contain an electroactive group. The well-known redox couple of anthraquinone/anthrahydroquinone has been used as the hydrophobic component for a series of small molecule gelators. They are further functionalized with peptide combinations of L-phenylalanine and glycine to provide the hydrophilic group to complete 'head-tail' models of self-assembling gels. The gelation and electroactive characteristics of the series were assessed. Cyclic voltammetry shows the reversible redox cycle to be only superficially altered by functionalization. Additionally, spectroelectrochemical measurements show a reversible transparency and colour change induced by the redox process.

  14. Self-assembling electroactive hydrogels for flexible display technology

    International Nuclear Information System (INIS)

    Jones, Scott L; Wong, Kok Hou; Ladouceur, Francois; Thordarson, Pall

    2010-01-01

    We have assessed the potential of self-assembling hydrogels for use in conformal displays. The self-assembling process can be used to alter the transparency of the material to all visible light due to scattering by fibres. The reversible transition is shown to be of low energy by differential scanning calorimetry. For use in technology it is imperative that this transition is controlled electrically. We have thus synthesized novel self-assembling hydrogelator molecules which contain an electroactive group. The well-known redox couple of anthraquinone/anthrahydroquinone has been used as the hydrophobic component for a series of small molecule gelators. They are further functionalized with peptide combinations of L-phenylalanine and glycine to provide the hydrophilic group to complete 'head-tail' models of self-assembling gels. The gelation and electroactive characteristics of the series were assessed. Cyclic voltammetry shows the reversible redox cycle to be only superficially altered by functionalization. Additionally, spectroelectrochemical measurements show a reversible transparency and colour change induced by the redox process.

  15. Facial Displays Are Tools for Social Influence.

    Science.gov (United States)

    Crivelli, Carlos; Fridlund, Alan J

    2018-05-01

    Based on modern theories of signal evolution and animal communication, the behavioral ecology view of facial displays (BECV) reconceives our 'facial expressions of emotion' as social tools that serve as lead signs to contingent action in social negotiation. BECV offers an externalist, functionalist view of facial displays that is not bound to Western conceptions about either expressions or emotions. It easily accommodates recent findings of diversity in facial displays, their public context-dependency, and the curious but common occurrence of solitary facial behavior. Finally, BECV restores continuity of human facial behavior research with modern functional accounts of non-human communication, and provides a non-mentalistic account of facial displays well-suited to new developments in artificial intelligence and social robotics. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  16. General multiplex centralized fire-alarm display system

    International Nuclear Information System (INIS)

    Zhu Liqun; Chen Jinming

    2002-01-01

    The fire-alarm display system is developed, which can connect with each type of fire controllers produced in the factory and SIGMASYS controllers. It can display whole alarm information. The display system software gathers communication, database and multimedia, has functions of inspecting fire, showing alarm, storing data, searching information and so on. The drawing software lets the user expediently add, delete, move and modify fire detection or fire fighting facilities on the building floor maps. The graphic transform software lets the display use the vectorgraph produced by popular plotting software such as Auto CAD. The system software provides the administration function, such as log book of changing shift and managing workers etc.. The software executed on Windows 98 platform. The user interface is friendly and reliable in operation

  17. Third-Generation Display Technology: Nominally Transparent Material

    Directory of Open Access Journals (Sweden)

    Charles Willow

    2010-12-01

    Full Text Available Display technology is reshaping the consumer, business, government, and even not-for-profit markets in the midst of the digital convergence, coupled with recent smart phones led by Apple, Inc. First-Generation (1G display technology was dominated by the Cathode Ray Tubes, followed by Liquid Crystal Display and Plasma in 2G. A radically innovative shift as a disruptive technology is expected to follow in 3G to utilize virtually any transparent material, which wirelessly connects to portable access points. This paper studies the feasibility of the 3G Display Technology (DT with Technology S-Curves, and presents possible business models and technology strategies which may be generated from it. Additional subsets of business models may be derived for a wide range of industry applications.

  18. Evaluation of Synthetic Vision Display Concepts for Improved Awareness in Unusual Attitude Recovery Scenarios

    Science.gov (United States)

    Nicholas, Stephanie

    2016-01-01

    ) scenarios; Part II included a set of fifty Attitude Memory Recall Tasks (AMRT). At the conclusion of each trial, EPs were asked to complete a set post-run questionnaires. Quantitative results showed that there were no significant statistical effects on UA recovery times when utilizing SV with or without the presence of a BAI. Qualitative results show the SV displays (color, texture) with BAI On are most preferred for both UA recognition and recovery when compared with the baseline display. When only comparing SV display concepts, EPs performed better when using the SV with texture, BAI On, than any other display configuration. This is an interesting find considering most EPs noted their preference towards the SV with color gradient when the BAI was on.

  19. Antibody engineering using phage display with a coiled-coil heterodimeric Fv antibody fragment.

    Directory of Open Access Journals (Sweden)

    Xinwei Wang

    Full Text Available A Fab-like antibody binding unit, ccFv, in which a pair of heterodimeric coiled-coil domains was fused to V(H and V(L for Fv stabilization, was constructed for an anti-VEGF antibody. The anti-VEGF ccFv showed the same binding affinity as scFv but significantly improved stability and phage display level. Furthermore, phage display libraries in the ccFv format were constructed for humanization and affinity maturation of the anti-VEGF antibody. A panel of V(H frameworks and V(H-CDR3 variants, with a significant improvement in affinity and expressibility in both E. coli and yeast systems, was isolated from the ccFv phage libraries. These results demonstrate the potential application of the ccFv antibody format in antibody engineering.

  20. Heterologous expression of carcinoembryonic antigen in Lactococcus lactis via LcsB-mediated surface displaying system for oral vaccine development.

    Science.gov (United States)

    Zhang, Xiaowei; Hu, Shumin; Du, Xue; Li, Tiejun; Han, Lanlan; Kong, Jian

    2016-12-01

    Carcinoembryonic antigen (CEA) is an attractive target for immunotherapy because it is expressed minimally in normal tissue, but is overexpressed in a wide variety of malignant epithelial tissues. Lactic acid bacteria (LABs), widely used in food processes, are attractive candidates for oral vaccination. Thus, we examined whether LABs could be used as a live vaccine vector to deliver CEA antigen. CEA was cloned into an Escherichia coli/Lactococcus lactis shuttle vector pSEC:LEISS under the control of a nisin promoter. For displaying the CEA on the cell surface of the L. lactis strain, the anchor motif LcsB from the S-layer protein of Lactobacillus crispatus was fused with CEA. Intracellular and cell surface expression of the CEA-LcsB fusion was confirmed by western blot analysis. Significantly higher levels of CEA-specific secretory immunoglobulin A in the sera of mice were observed upon oral administration of strain cultures containing the CEA-LcsB fused protein. In addition, the CEA-LcsB antigen group showed a higher spleen index compared to the CEA antigen alone or negative control, demonstrating that surface-displayed CEA antigen could induce a higher immune response. These results provided the first evidence for displaying CEA antigen on the cell surfaces of LABs as oral vaccines against cancer or infectious diseases. Copyright © 2014. Published by Elsevier B.V.

  1. Who believes us when we try to conceal our prejudices? The effectiveness of moral credentials with in-groups versus out-groups.

    Science.gov (United States)

    Krumm, Angela J; Corning, Alexandra F

    2008-12-01

    Moral credentials are pieces of evidence accrued by individuals that can later be presented, intentionally or unintentionally, as a record of their lack of prejudice (B. Monin & D. T. Miller, 2001). For example, attending a gay pride march or being an openly gay person ostensibly credentials an individual to tell gay jokes free of concern that he or she will be labeled prejudiced. The authors tested whether displays of moral credentials actually work to insulate individuals from attributions of prejudice by others. Results indicated that displays of moral credentials generally discourage attributions of discrimination but unevenly so, depending on who makes the judgment. Consistent with predictions from social identity theory (H. Tajfel & J. C. Turner, 1979), participants most swayed by displays of moral credentials were those who shared an in-group status with the person displaying the moral credentials.

  2. Experience in the review of utility control room design review and safety parameter display system programs

    International Nuclear Information System (INIS)

    Moore, V.A.

    1985-01-01

    The Detailed Control Room Design Review (DCRDR) and the Safety Parameter Display System (SPDS) had their origins in the studies and investigations conducted as the result of the TMI-2 accident. The President's Commission (Kemeny Commission) critized NRC for not examining the man-machine interface, over-emphasizing equipment, ignoring human beings, and tolerating outdated technology in control rooms. The Commission's Special Inquiry Group (Rogovin Report) recommended greater application of human factors engineering including better instrumentation displays and improved control room design. The NRC Lessons Learned Task Force concluded that licensees should review and improve control rooms using NRC Human engineering guidelines, and install safety parameter display systems (then called the safety staff vector). The TMI Action Plan Item I.D.1 and I.D.2 were based on these recommendations

  3. Educational Testing of an Auditory Display of Mars Gamma Ray Spectrometer Data

    Science.gov (United States)

    Keller, J. M.; Pompea, S. M.; Prather, E. E.; Slater, T. F.; Boynton, W. V.; Enos, H. L.; Quinn, M.

    2003-12-01

    A unique, alternative educational and public outreach product was created to investigate the use and effectiveness of auditory displays in science education. The product, which allows students to both visualize and hear seasonal variations in data detected by the Gamma Ray Spectrometer (GRS) aboard the Mars Odyssey spacecraft, consists of an animation of false-color maps of hydrogen concentrations on Mars along with a musical presentation, or sonification, of the same data. Learners can access this data using the visual false-color animation, the auditory false-pitch sonification, or both. Central to the development of this product is the question of its educational effectiveness and implementation. During the spring 2003 semester, three sections of an introductory astronomy course, each with ˜100 non-science undergraduates, were presented with one of three different exposures to GRS hydrogen data: one auditory, one visual, and one both auditory and visual. Student achievement data was collected through use of multiple-choice and open-ended surveys administered before, immediately following, and three and six weeks following the experiment. It was found that the three student groups performed equally well in their ability to perceive and interpret the data presented. Additionally, student groups exposed to the auditory display reported a higher interest and engagement level than the student group exposed to the visual data alone. Based upon this preliminary testing,we have made improvements to both the educational product and our evaluation protocol. This fall, we will conduct further testing with ˜100 additional students, half receiving auditory data and half receiving visual data, and we will conduct interviews with individual students as they interface with the auditory display. Through this process, we hope to further assess both learning and engagement gains associated with alternative and multi-modal representations of scientific data that extend beyond

  4. Development of anti-infectives using phage display: biological agents against bacteria, viruses, and parasites.

    Science.gov (United States)

    Huang, Johnny X; Bishop-Hurley, Sharon L; Cooper, Matthew A

    2012-09-01

    The vast majority of anti-infective therapeutics on the market or in development are small molecules; however, there is now a nascent pipeline of biological agents in development. Until recently, phage display technologies were used mainly to produce monoclonal antibodies (MAbs) targeted against cancer or inflammatory disease targets. Patent disputes impeded broad use of these methods and contributed to the dearth of candidates in the clinic during the 1990s. Today, however, phage display is recognized as a powerful tool for selecting novel peptides and antibodies that can bind to a wide range of antigens, ranging from whole cells to proteins and lipid targets. In this review, we highlight research that exploits phage display technology as a means of discovering novel therapeutics against infectious diseases, with a focus on antimicrobial peptides and antibodies in clinical or preclinical development. We discuss the different strategies and methods used to derive, select, and develop anti-infectives from phage display libraries and then highlight case studies of drug candidates in the process of development and commercialization. Advances in screening, manufacturing, and humanization technologies now mean that phage display can make a significant contribution in the fight against clinically important pathogens.

  5. Transplantation of N-Acetyl Aspartyl-Glutamate Synthetase-Activated Neural Stem Cells after Experimental Traumatic Brain Injury Significantly Improves Neurological Recovery

    Directory of Open Access Journals (Sweden)

    Mingfeng Li

    2013-12-01

    Full Text Available Background/Aims: Neural stem cells (NSCs hold considerable potential as a therapeutic tool for repair of the damaged nervous system. In the current study, we examined whether transplanted N-acetyl aspartyl-glutamate synthetase (NAAGS-activated NSCs (NAAGS/NSCs further improve neurological recovery following traumatic brain injury (TBI in Sprague-Dawley rats. Methods: Animals received TBI and stereotactic injection of NSCs, NAAGS/NSCs or phosphate buffered saline without cells (control into the injured cortex. NAAGS protein expression was detected through western blot analysis. Dialysate NAAG levels were analyzed with radioimmunoassay. Cell apoptosis was detected via TUNEL staining. The expression levels of specific pro-inflammatory cytokines were detected with enzyme-linked immunosorbent assay. Results: Groups with transplanted NSCs and NAAGS/NSCs displayed significant recovery of the motor behavior, compared to the control group. At 14 and 21 days post-transplantation, the motor behavior in NAAGS/NSC group was significantly improved than that in NSC group (pConclusion: Our results collectively demonstrate that NAAGS/NSCs provide a more powerful autoplastic therapy for the injured nervous system.

  6. Safety parameter display system for Kalinin NPP

    International Nuclear Information System (INIS)

    Andreev, V.I.; Videneev, E.N.; Tissot, J.C.; Joonekindt, D.; Davidenko, N.N.; Shaftan, G.I.; Dounaev, V.G.; Neboyan, V.T.

    1995-01-01

    The paper discusses the safety parameter display system (SPDS), which is being designed for Kalinin NPP. The assessment of the safety status of the plant is done by the continuous monitoring of six critical safety functions and the corresponding status trees. Besides, a number of additional functions are realized within the scope of KlnNPP, aimed at providing the operator and the safety engineer in the main control room with more detailed information in accidental situation as well as during the normal operation. In particular, these functions are: archiving, data logs and alarm handling, safety actions monitoring, mnemonic diagrams indicating the state of main technological equipment and basic plant parameters, reference data, etc. As compared with the traditional scope of functions of this kind of systems, the functionality of KlnNPP SPDS is significantly expanded due to the inclusion in it the operator support function ''computerized procedures''. The basic SPDS implementation platform is ADACS of SEMA GROUP design. The system architecture includes two workstations in the main control room: one is for reactor operator and the other one for safety engineer. Every station has two CRT screens which ensures computerized procedures implementation and provides for extra services for the operator. Also, the information from the SPDS is transmitted to the local crisis center and to the crisis center of the State utility organization concern ''Rosenergoatom''. (author). 3 refs, 6 figs, 1 tab

  7. COMMUNICATIONS GROUP

    CERN Multimedia

    L. Taylor

    2012-01-01

      Outreach and Education We are fortunate that our research has captured the public imagination, even though this inevitably puts us under the global media spotlight, as we saw with the Higgs seminar at CERN in December, which had 110,000 distinct webcast viewers. The media interest was huge with 71 media organisations registering to come to CERN to cover the Higgs seminar, which was followed by a press briefing with the DG and Spokespersons. This event resulted in about 2,000 generally positive stories in the global media. For this seminar, the CMS Communications Group prepared up-to-date news and public material, including links to the CMS results, animations and event displays [http://cern.ch/go/Ch8thttp://cern.ch/go/Ch8t]. There were 44,000 page-views on the CMS public website, with the Higgs news article being by far the most popular item. CMS event displays from iSpy are fast becoming the iconic media images, featuring on numerous major news outlets (BBC, CNN, MSN...) as well as in the sci...

  8. Dry eye disease and work productivity loss in visual display users: the Osaka study.

    Science.gov (United States)

    Uchino, Miki; Uchino, Yuichi; Dogru, Murat; Kawashima, Motoko; Yokoi, Norihiko; Komuro, Aoi; Sonomura, Yukiko; Kato, Hiroaki; Kinoshita, Shigeru; Schaumberg, Debra A; Tsubota, Kazuo

    2014-02-01

    To estimate the impact of dry eye disease (DED) on work performance and productivity in office workers using visual display terminals (VDTs). Cross-sectional study. Six hundred seventy-two Japanese young and middle-aged office workers using VDTs completed a questionnaire that was designed to measured at-work performance deficits and productivity losses using the Japanese version of the Work Limitations Questionnaire, completed by e-mail. Using the Japanese dry eye diagnostic criteria, respondents were classified into 3 groups: definite DED, probable DED, and non DED. Of the 672 office workers, 553 subjects (82.3%), including 366 men and 187 women, completed the questionnaire and underwent clinical evaluation. As for the total workplace productivity loss, the non DED group demonstrated a loss of 3.56%, those with probable DED demonstrated a loss of 4.06%, and those with definite DED demonstrated a loss of 4.82%, indicating significantly worse performance and productivity (P = .014, trend test). For the 4 subscales, DED was associated with significantly lower on-the-job time management (P = .009, trend test) and combined mental performance and interpersonal functioning (P = .011, trend test). After controlling for age, sex, VDT working hours, and diagnosis of DED, time management, physical demands, and mental and interpersonal functioning showed a significant relationship to DED (each P > .05). Annual DED productivity losses were estimated to be $6160 per employee when measured by total production and $1178 per employee calculated by wage. This study indicated that there is a significant impact of DED on the total productivity of Japanese VDT users. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. COREMAP: Graphical user interface for displaying reactor core data in an interactive hexagon map

    International Nuclear Information System (INIS)

    Muscat, F.L.; Derstine, K.L.

    1995-01-01

    COREMAP is a Graphical User Interface (GUI) designed to assist users read and check reactor core data from multidimensional neutronic simulation models in color and/or as text in an interactive 2D planar grid of hexagonal subassemblies. COREMAP is a complete GEODST/RUNDESC viewing tool which enables the user to access multi data set files (e.g. planes, moments, energy groups ,... ) and display up to two data sets simultaneously, one as color and the other as text. The user (1) controls color scale characteristics such as type (linear or logarithmic) and range limits, (2) controls the text display based upon conditional statements on data spelling, and value. (3) chooses zoom features such as core map size, number of rings and surrounding subassemblies, and (4) specifies the data selection for supplied popup subwindows which display a selection of data currently off-screen for a selected cell, as a list of data and/or as a graph. COREMAP includes a RUNDESC file editing tool which creates ''proposed'' Run-description files by point and click revisions to subassembly assignments in an existing EBRII Run-description file. COREMAP includes a fully automated printing option which creates high quality PostScript color or greyscale images of the core map independent of the monitor used, e.g. color prints can be generated with a session from a color or monochrome monitor. The automated PostScript output is an alternative to the xgrabsc based printing option. COREMAP includes a plotting option which creates graphs related to a selected cell. The user specifies the X and Y coordinates types (planes, moment, group, flux ,... ) and a parameter, P, when displaying several curves for the specified (X, Y) pair COREMAP supports hexagonal geometry reactor core configurations specified by: the GEODST file and binary Standard Interface Files and the RUNDESC ordering

  10. An integrated acquisition, display, and analysis system

    International Nuclear Information System (INIS)

    Ahmad, T.; Huckins, R.J.

    1987-01-01

    The design goal of the ND9900/Genuie was to integrate a high performance data acquisition and display subsystem with a state-of-the-art 32-bit supermicrocomputer. This was achieved by integrating a Digital Equipment Corporation MicroVAX II CPU board with acquisition and display controllers via the Q-bus. The result is a tightly coupled processing and analysis system for Pulse Height Analysis and other applications. The system architecture supports distributed processing, so that acquisition and display functions are semi-autonomous, making the VAX concurrently available for applications programs

  11. Review of defense display research programs

    Science.gov (United States)

    Tulis, Robert W.; Hopper, Darrel G.; Morton, David C.; Shashidhar, Ranganathan

    2001-09-01

    Display research has comprised a substantial portion of the defense investment in new technology for national security for the past 13 years. These investments have been made by the separate service departments and, especially, via several Defense Research Projects Agency (DARPA) programs, known collectively as the High Definition Systems (HDS) Program (which ended in 2001) and via the Office of the Secretary of Defense (OSD) Defense Production Act (DPA) Title III Program (efforts ended in 2000). Using input from the Army, Navy, and Air Force to focus research and identify insertion opportunities, DARPA and the Title III Program Office have made investments to develop the national technology base and manufacturing infrastructure necessary to meet the twin challenge of providing affordable displays in current systems and enabling the DoD strategy of winning future conflicts by getting more information to all participants during the battle. These completed DARPA and DPA research and infrastructure programs are reviewed. Service investments have been and are being made to transition display technology; examples are described. Display science and technology (S&T) visions are documented for each service to assist the identification of areas meriting consideration for future defense research.

  12. 3D Display of Spacecraft Dynamics Using Real Telemetry

    Directory of Open Access Journals (Sweden)

    Sanguk Lee

    2002-12-01

    Full Text Available 3D display of spacecraft motion by using telemetry data received from satellite in real-time is described. Telemetry data are converted to the appropriate form for 3-D display by the real-time preprocessor. Stored playback telemetry data also can be processed for the display. 3D display of spacecraft motion by using real telemetry data provides intuitive comprehension of spacecraft dynamics.

  13. A Framework for Realistic Modeling and Display of Object Surface Appearance

    Science.gov (United States)

    Darling, Benjamin A.

    With advances in screen and video hardware technology, the type of content presented on computers has progressed from text and simple shapes to high-resolution photographs, photorealistic renderings, and high-definition video. At the same time, there have been significant advances in the area of content capture, with the development of devices and methods for creating rich digital representations of real-world objects. Unlike photo or video capture, which provide a fixed record of the light in a scene, these new technologies provide information on the underlying properties of the objects, allowing their appearance to be simulated for novel lighting and viewing conditions. These capabilities provide an opportunity to continue the computer display progression, from high-fidelity image presentations to digital surrogates that recreate the experience of directly viewing objects in the real world. In this dissertation, a framework was developed for representing objects with complex color, gloss, and texture properties and displaying them onscreen to appear as if they are part of the real-world environment. At its core, there is a conceptual shift from a traditional image-based display workflow to an object-based one. Instead of presenting the stored patterns of light from a scene, the objective is to reproduce the appearance attributes of a stored object by simulating its dynamic patterns of light for the real viewing and lighting geometry. This is accomplished using a computational approach where the physical light sources are modeled and the observer and display screen are actively tracked. Surface colors are calculated for the real spectral composition of the illumination with a custom multispectral rendering pipeline. In a set of experiments, the accuracy of color and gloss reproduction was evaluated by measuring the screen directly with a spectroradiometer. Gloss reproduction was assessed by comparing gonio measurements of the screen output to measurements of the

  14. Finding-specific display presets for computed radiography soft-copy reading.

    Science.gov (United States)

    Andriole, K P; Gould, R G; Webb, W R

    1999-05-01

    Much work has been done to optimize the display of cross-sectional modality imaging examinations for soft-copy reading (i.e., window/level tissue presets, and format presentations such as tile and stack modes, four-on-one, nine-on-one, etc). Less attention has been paid to the display of digital forms of the conventional projection x-ray. The purpose of this study is to assess the utility of providing presets for computed radiography (CR) soft-copy display, based not on the window/level settings, but on processing applied to the image optimized for visualization of specific findings, pathologies, etc (i.e., pneumothorax, tumor, tube location). It is felt that digital display of CR images based on finding-specific processing presets has the potential to: speed reading of digital projection x-ray examinations on soft copy; improve diagnostic efficacy; standardize display across examination type, clinical scenario, important key findings, and significant negatives; facilitate image comparison; and improve confidence in and acceptance of soft-copy reading. Clinical chest images are acquired using an Agfa-Gevaert (Mortsel, Belgium) ADC 70 CR scanner and Fuji (Stamford, CT) 9000 and AC2 CR scanners. Those demonstrating pertinent findings are transferred over the clinical picture archiving and communications system (PACS) network to a research image processing station (Agfa PS5000), where the optimal image-processing settings per finding, pathologic category, etc, are developed in conjunction with a thoracic radiologist, by manipulating the multiscale image contrast amplification (Agfa MUSICA) algorithm parameters. Soft-copy display of images processed with finding-specific settings are compared with the standard default image presentation for 50 cases of each category. Comparison is scored using a 5-point scale with the positive scale denoting the standard presentation is preferred over the finding-specific processing, the negative scale denoting the finding

  15. ENERGY STAR Certified Displays

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 7.0 ENERGY STAR Program Requirements for Displays that are effective as of July 1, 2016....

  16. Display methods of electronic patient record screens: patient privacy concerns.

    Science.gov (United States)

    Niimi, Yukari; Ota, Katsumasa

    2013-01-01

    To provide adequate care, medical professionals have to collect not only medical information but also information that may be related to private aspects of the patient's life. With patients' increasing awareness of information privacy, healthcare providers have to pay attention to the patients' right of privacy. This study aimed to clarify the requirements of the display method of electronic patient record (EPR) screens in consideration of both patients' information privacy concerns and health professionals' information needs. For this purpose, semi-structured group interviews were conducted of 78 medical professionals. They pointed out that partial concealment of information to meet patients' requests for privacy could result in challenges in (1) safety in healthcare, (2) information sharing, (3) collaboration, (4) hospital management, and (5) communication. They believed that EPRs should (1) meet the requirements of the therapeutic process, (2) have restricted access, (3) provide convenient access to necessary information, and (4) facilitate interprofessional collaboration. This study provides direction for the development of display methods that balance the sharing of vital information and protection of patient privacy.

  17. CERN students display their work

    CERN Multimedia

    Anaïs Schaeffer

    2011-01-01

    The first poster session by students working on the LHC experiments, organised by the LPCC, was a great success. Showcasing the talents of over a hundred young physicists from all over the world, it was an opportunity for everyone at CERN to check out the wide range of research work being done by the new generation of physicists at CERN.   At 5.30 p.m. on Wednesday 23 March, the first poster session by CERN students took place in Restaurant No.1, where no fewer than 87 posters went on public display. The students were split into 8 groups according to their research field* and all were on hand to answer the questions of an inquisitive audience. TH Department's Michelangelo Mangano, who is head of the LHC Physics Centre at CERN (LPCC) and is responsible for the initiative, confirms that nothing was left to chance, even the choice of date: "We wanted to make the most of the general enthusiasm around the winter conferences and the meeting of the LHC Experiments Committee to present the stud...

  18. The Real Time Interactive Display Environment (RTIDE), a display building tool developed by Space Shuttle flight controllers

    Science.gov (United States)

    Kalvelage, Thomas A.

    1989-01-01

    NASA's Mission Control Center, located at Johnson Space Center, is incrementally moving from a centralized architecture to a distributed architecture. Starting with STS-29, some host-driven console screens will be replaced with graphics terminals driven by workstations. These workstations will be supplied realtime data first by the Real Time Data System (RTDS), a system developed inhouse, and then months later (in parallel with RTDS) by interim and subsequently operational versions of the Mission Control Center Upgrade (MCCU) software package. The Real Time Interactive Display Environment (RTIDE) was built by Space Shuttle flight controllers to support the rapid development of multiple new displays to support Shuttle flights. RTIDE is a display building tool that allows non-programmers to define object-oriented, event-driven, mouseable displays. Particular emphasis was placed on upward compatibility between RTIDE versions, ability to acquire data from different data sources, realtime performance, ability to modularly upgrade RTIDE, machine portability, and a clean, powerful user interface. The operational and organizational factors that drove RTIDE to its present form, the actual design itself, simulation and flight performance, and lessons learned in the process are discussed.

  19. Advanced Plasmonic Materials for Dynamic Color Display.

    Science.gov (United States)

    Shao, Lei; Zhuo, Xiaolu; Wang, Jianfang

    2018-04-01

    Plasmonic structures exhibit promising applications in high-resolution and durable color generation. Research on advanced hybrid plasmonic materials that allow dynamically reconfigurable color control has developed rapidly in recent years. Some of these results may give rise to practically applicable reflective displays in living colors with high performance and low power consumption. They will attract broad interest from display markets, compared with static plasmonic color printing, for example, in applications such as digital signage, full-color electronic paper, and electronic device screens. In this progress report, the most promising recent examples of utilizing advanced plasmonic materials for the realization of dynamic color display are highlighted and put into perspective. The performances, advantages, and disadvantages of different technologies are discussed, with emphasis placed on both the potential and possible limitations of various hybrid materials for dynamic plasmonic color display. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Identifying Bacterial Immune Evasion Proteins Using Phage Display.

    Science.gov (United States)

    Fevre, Cindy; Scheepmaker, Lisette; Haas, Pieter-Jan

    2017-01-01

    Methods aimed at identification of immune evasion proteins are mainly rely on in silico prediction of sequence, structural homology to known evasion proteins or use a proteomics driven approach. Although proven successful these methods are limited by a low efficiency and or lack of functional identification. Here we describe a high-throughput genomic strategy to functionally identify bacterial immune evasion proteins using phage display technology. Genomic bacterial DNA is randomly fragmented and ligated into a phage display vector that is used to create a phage display library expressing bacterial secreted and membrane bound proteins. This library is used to select displayed bacterial secretome proteins that interact with host immune components.

  1. Peer groups and operational cycle enhancements to the performance indicator report

    International Nuclear Information System (INIS)

    Stromberg, H.M.; DeHaan, M.S.; Gentillon, C.D.; Wilson, G.E.; Vanden Heuvel, L.N.

    1992-01-01

    Accurate performance evaluation and plant trending by the performance indicator program are integral parts of monitoring the operation of commercial nuclear power plants. The presentations of the NRC/AEOD performance indicator program have undergone a number of enhancements. The diversity of the commercial nuclear plants, coupled with continued improvements in the performance indicator program, has resulted in the evaluation of plants in logical peer groups and highlighted the need to evaluate the impact of plant operational conditions on the performance indicators. These enhancements allow a more-meaningful evaluation of operating commercial nuclear power plant performance. This report proposes methods to enhance the presentation of the performance indicator data by analyzing the data in logical peer groups and displaying the performance indicator data based on the operational status of the plants. Previously, preliminary development of the operational cycle displays of the performance indicator data was documented. This report extends the earlier findings and presents the continued development of the peer groups and operational cycle trend and deviation data and displays. This report describes the peer groups and enhanced PI data presentations by considering the operational cycle phase breakdowns, calculation methods, and presentation methods

  2. Clinical significance of plasminogen activator inhibitor activity in patients with exercise-induced ischemia

    International Nuclear Information System (INIS)

    Sakata, K.; Kurata, C.; Taguchi, T.; Suzuki, S.; Kobayashi, A.; Yamazaki, N.; Rydzewski, A.; Takada, Y.; Takada, A.

    1990-01-01

    To assess the fibrinolytic system in patients with exercise-induced ischemia and its relation to ischemia and severity of coronary artery disease (CAD), 47 patients with CAD confirmed by results of coronary angiography underwent symptom-limited multistage exercise thallium-201 emission computed tomography. All patients with CAD had exercise-induced ischemia as assessed from thallium-201 images. Pre- and peak exercise blood samples from each patient and preexercise blood samples from control subjects were assayed for several fibrinolytic components and were also assayed for plasma adrenaline. The extent of ischemia was defined as delta visual uptake score (total visual uptake score in delayed images minus total visual uptake score in initial images) and the severity of CAD as the number of diseased vessels. In the basal condition, plasminogen activator inhibitor (PAI) activity was significantly higher in patients with exercise-induced ischemia as compared to control subjects (p less than 0.01), although there were no significant differences in other fibrinolytic variables between the two groups. Moreover, PAI activity in the basal condition displayed a significantly positive correlation with the extent of ischemia (r = 0.47, p less than 0.01). Patients with exercise-induced ischemia were divided into two groups (24 with single-vessel disease and 23 with multivessel disease). There were no significant differences in coronary risk factors, hemodynamics, or plasma adrenaline levels during exercise between single-vessel and multivessel disease except that delta visual uptake score was significantly higher in multivessel disease (p less than 0.01)

  3. Workshop on data-acquisition and -display systems: directions after TMI

    International Nuclear Information System (INIS)

    1980-11-01

    The accident at Three Mile Island Unit-2 raised questions as to the adequacy of data acquisition and display systems in commercial nuclear power plants. A series of recommendations have developed from the various groups that have analyzed the accident in order to improve the oprator's overview of the plant safety conditions and to facilitate information transfer to technical support centers in emergency situations. This report is the result of an NSAC-sponsored workshop, where the various recommendations and emerging regulatory requirements were reviewed in an attempt to provide an integrated basis for their implementation

  4. Group Work in Schools: A Process Consultation Approach

    Science.gov (United States)

    Farouk, Shaalan

    2004-01-01

    This paper provides a description of how an educational psychologist can consult with groups of teachers mostly in relation to their work with pupils who display emotional behavioural difficulties. The paper includes a review of the work on group consultation in schools, followed by a description of process consultation (Schein, 1988 ) and how the…

  5. Human factors guidelines for large-screen displays

    International Nuclear Information System (INIS)

    Collier, Steve

    2005-09-01

    Any control-room project (including upgrades or evolutionary improvements to existing control-rooms) is well advised at the outset first to gather and update related background material for the design. This information-gathering exercise should also take into account experience from similar projects and operating experience. For these reasons, we decided to use our research, and experience in large-screen display design with several clients to update human factors guidance for large-screen displays, to take into account new ergonomics guidelines, operating experience, and work from similar projects. To write the updated guidelines, we drew on much of our experience across several departments at IFE, including research funded by the HRP programme, and experience with individual clients. Guidance here is accordingly focused mainly on recent areas of technical and human innovations in the man-machine interface. One particular area of focus was on the increasing use of large-screen display systems in modern control-rooms, and on how guidelines could be adapted and supplemented for their design. Guidance or reference to recommended sources is also given for control suite arrangement and layout, control-room layout, workstation layout, design of displays and controls, and design of the work environment, especially insofar as these ergonomic issues interact with the effectiveness of modern displays, in particular large screen displays. The work shows that there can be synergy between HRP research and bilateral activities: the one side offers a capability to develop tools and guidelines, while the other side gives an opportunity to test and refine these in practice, to the benefit of both parties. (Author)

  6. Human factors guidelines for large-screen displays

    Energy Technology Data Exchange (ETDEWEB)

    Collier, Steve

    2005-09-15

    Any control-room project (including upgrades or evolutionary improvements to existing control-rooms) is well advised at the outset first to gather and update related background material for the design. This information-gathering exercise should also take into account experience from similar projects and operating experience. For these reasons, we decided to use our research, and experience in large-screen display design with several clients to update human factors guidance for large-screen displays, to take into account new ergonomics guidelines, operating experience, and work from similar projects. To write the updated guidelines, we drew on much of our experience across several departments at IFE, including research funded by the HRP programme, and experience with individual clients. Guidance here is accordingly focused mainly on recent areas of technical and human innovations in the man-machine interface. One particular area of focus was on the increasing use of large-screen display systems in modern control-rooms, and on how guidelines could be adapted and supplemented for their design. Guidance or reference to recommended sources is also given for control suite arrangement and layout, control-room layout, workstation layout, design of displays and controls, and design of the work environment, especially insofar as these ergonomic issues interact with the effectiveness of modern displays, in particular large screen displays. The work shows that there can be synergy between HRP research and bilateral activities: the one side offers a capability to develop tools and guidelines, while the other side gives an opportunity to test and refine these in practice, to the benefit of both parties. (Author)

  7. Real-time Image Generation for Compressive Light Field Displays

    International Nuclear Information System (INIS)

    Wetzstein, G; Lanman, D; Hirsch, M; Raskar, R

    2013-01-01

    With the invention of integral imaging and parallax barriers in the beginning of the 20th century, glasses-free 3D displays have become feasible. Only today—more than a century later—glasses-free 3D displays are finally emerging in the consumer market. The technologies being employed in current-generation devices, however, are fundamentally the same as what was invented 100 years ago. With rapid advances in optical fabrication, digital processing power, and computational perception, a new generation of display technology is emerging: compressive displays exploring the co-design of optical elements and computational processing while taking particular characteristics of the human visual system into account. In this paper, we discuss real-time implementation strategies for emerging compressive light field displays. We consider displays composed of multiple stacked layers of light-attenuating or polarization-rotating layers, such as LCDs. The involved image generation requires iterative tomographic image synthesis. We demonstrate that, for the case of light field display, computed tomographic light field synthesis maps well to operations included in the standard graphics pipeline, facilitating efficient GPU-based implementations with real-time framerates.

  8. An intelligent system and a relational data base for codifying helmet-mounted display symbology design requirements

    Science.gov (United States)

    Rogers, Steven P.; Hamilton, David B.

    1994-06-01

    To employ the most readily comprehensible presentation methods and symbology with helmet-mounted displays (HMDs), it is critical to identify the information elements needed to perform each pilot function and to analytically determine the attributes of these elements. The extensive analyses of mission requirements currently performed for pilot-vehicle interface design can be aided and improved by the new capabilities of intelligent systems and relational databases. An intelligent system, named ACIDTEST, has been developed specifically for organizing and applying rules to identify the best display modalities, locations, and formats. The primary objectives of the ACIDTEST system are to provide rapid accessibility to pertinent display research data, to integrate guidelines from many disciplines and identify conflicts among these guidelines, to force a consistent display approach among the design team members, and to serve as an 'audit trail' of design decisions and justifications. A powerful relational database called TAWL ORDIR has been developed to document information requirements and attributes for use by ACIDTEST as well as to greatly augment the applicability of mission analysis data. TAWL ORDIR can be used to rapidly reorganize mission analysis data components for study, perform commonality analyses for groups of tasks, determine the information content requirement for tailored display modes, and identify symbology integration opportunities.

  9. Hewlett-Packard's Approaches to Full Color Reflective Displays

    Science.gov (United States)

    Gibson, Gary

    2012-02-01

    Reflective displays are desirable in applications requiring low power or daylight readability. However, commercial reflective displays are currently either monochrome or capable of only dim color gamuts. Low cost, high-quality color technology would be rapidly adopted in existing reflective display markets and would enable new solutions in areas such as retail pricing and outdoor digital signage. Technical breakthroughs are required to enable bright color gamuts at reasonable cost. Pixel architectures that rely on pure reflection from a single layer of side-by-side primary-color sub-pixels use only a fraction of the display area to reflect incident light of a given color and are, therefore, unacceptably dark. Reflective devices employing stacked color primaries offer the possibility of a somewhat brighter color gamut but can be more complex to manufacture. In this talk, we describe HP's successes in addressing these fundamental challenges and creating both high performance stacked-primary reflective color displays as well as inexpensive single layer prototypes that provide good color. Our stacked displays utilize a combination of careful light management techniques, proprietary high-contrast electro-optic shutters, and highly transparent active-matrix TFT arrays based on transparent metal oxides. They also offer the possibility of relatively low cost manufacturing through roll-to-roll processing on plastic webs. To create even lower cost color displays with acceptable brightness, we have developed means for utilizing photoluminescence to make more efficient use of ambient light in a single layer device. Existing reflective displays create a desired color by reflecting a portion of the incident spectrum while absorbing undesired wavelengths. We have developed methods for converting the otherwise-wasted absorbed light to desired wavelengths via tailored photoluminescent composites. Here we describe a single active layer prototype display that utilizes these materials

  10. NIST display colorimeter calibration facility

    Science.gov (United States)

    Brown, Steven W.; Ohno, Yoshihiro

    2003-07-01

    A facility has been developed at the National Institute of Standards and Technology (NIST) to provide calibration services for color-measuring instruments to address the need for improving and certifying the measurement uncertainties of this type of instrument. While NIST has active programs in photometry, flat panel display metrology, and color and appearance measurements, these are the first services offered by NIST tailored to color-measuring instruments for displays. An overview of the facility, the calibration approach, and associated uncertainties are presented. Details of a new tunable colorimetric source and the development of new transfer standard instruments are discussed.

  11. 3D Image Display Courses for Information Media Students.

    Science.gov (United States)

    Yanaka, Kazuhisa; Yamanouchi, Toshiaki

    2016-01-01

    Three-dimensional displays are used extensively in movies and games. These displays are also essential in mixed reality, where virtual and real spaces overlap. Therefore, engineers and creators should be trained to master 3D display technologies. For this reason, the Department of Information Media at the Kanagawa Institute of Technology has launched two 3D image display courses specifically designed for students who aim to become information media engineers and creators.

  12. Lateralisation of aggressive displays in a tephritid fly

    Science.gov (United States)

    Benelli, Giovanni; Donati, Elisa; Romano, Donato; Stefanini, Cesare; Messing, Russell H.; Canale, Angelo

    2015-02-01

    Lateralisation (i.e. different functional and/or structural specialisations of the left and right sides of the brain) of aggression has been examined in several vertebrate species, while evidence for invertebrates is scarce. In this study, we investigated lateralisation of aggressive displays (boxing with forelegs and wing strikes) in the Mediterranean fruit fly, Ceratitis capitata. We attempted to answer the following questions: (1) do medflies show lateralisation of aggressive displays at the population-level; (2) are there sex differences in lateralisation of aggressive displays; and (3) does lateralisation of aggression enhance fighting success? Results showed left-biased population-level lateralisation of aggressive displays, with no consistent differences among sexes. In both male-male and female-female conflicts, aggressive behaviours performed with left body parts led to greater fighting success than those performed with right body parts. As we found left-biased preferential use of body parts for both wing strikes and boxing, we predicted that the left foreleg/wing is quicker in exploring/striking than the right one. We characterised wing strike and boxing using high-speed videos, calculating mean velocity of aggressive displays. For both sexes, aggressive displays that led to success were faster than unsuccessful ones. However, left wing/legs were not faster than right ones while performing aggressive acts. Further research is needed on proximate causes allowing enhanced fighting success of lateralised aggressive behaviour. This is the first report supporting the adaptive role of lateralisation of aggressive displays in insects.

  13. A green-color portable waveguide eyewear display system

    Science.gov (United States)

    Xia, Lingbo; Xu, Ke; Wu, Zhengming; Hu, Yingtian; Li, Zhenzhen; Wang, Yongtian; Liu, Juan

    2013-08-01

    Waveguide display systems are widely used in various display fields, especially in head mounted display. Comparing with the traditional head mounted display system, this device dramatically reduce the size and mass. However, there are still several fatal problems such as high scatting, the cumbersome design and chromatic aberration that should be solved. We designed and fabricated a monochromatic portable eyewear display system consist of a comfortable eyewear device and waveguide system with two holographic gratings located on the substrate symmetrically. We record the gratings on the photopolymer medium with high efficiency and wavelength sensitivity. The light emitting from the micro-display is diffracted by the grating and trapped in the glass substrate by total internal reflection. The relationship between the diffraction efficiency and exposure value is studied and analyzed, and we fabricated the gratings with appropriate diffraction efficiency in a optimization condition. To avoid the disturbance of the stray light, we optimize the waveguide system numerically and perform the optical experiments. With this system, people can both see through the waveguide to obtain the information outside and catch the information from the micro display. After considering the human body engineering and industrial production, we design the structure in a compact and portable way. It has the advantage of small-type configuration and economic acceptable. It is believe that this kind of planar waveguide system is a potentially replaceable choice for the portable devices in future mobile communications.

  14. The silent salesman: an observational study of personal tobacco pack display at outdoor café strips in Australia.

    Science.gov (United States)

    Wakefield, Melanie A; Zacher, Meghan; Bayly, Megan; Brennan, Emily; Dono, Joanne; Miller, Caroline; Durkin, Sarah J; Scollo, Michelle M

    2014-07-01

    We sought to determine the relative frequency and nature of personal display of cigarette packs by smokers in two Australian cities where 30% front-of-pack and 90% back-of-pack health warnings have been used since 2006 and comprehensive tobacco marketing restrictions apply. An observational study counted patrons, active smokers and tobacco packs at cafés, restaurants and bars with outdoor seating. Pack orientation and use of cigarette cases were also noted. Overall, 18954 patrons, 1576 active smokers and 2153 packs were observed, meaning that one out of every 12.0 patrons was actively smoking, and one of every 8.8 patrons displayed a pack. Packs were more frequently observed in lower socio-economic neighbourhoods, reflecting the higher prevalence of smoking in those regions. Packs were displayed less often in venues where children were present, suggesting a greater tendency not to smoke around children. Most packs (81.4%) were oriented face-up, permitting prominent brand display. Only 1.5% of observed packs were cigarette cases, and 4.2% of packs were concealed by another item, such as a phone or wallet. Tobacco packs are frequently seen on table-tops in café strips, providing many opportunities for other patrons and passers-by to be incidentally exposed to cigarette brand names and imagery. Use of cigarette cases is rare, suggesting that smokers eventually habituate to pictorial warnings on branded packs and/or find repeated decanting of each newly purchased branded pack into a case to be inconvenient. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  15. A Qualitative Method to Estimate HSI Display Complexity

    International Nuclear Information System (INIS)

    Hugo, Jacques; Gertman, David

    2013-01-01

    There is mounting evidence that complex computer system displays in control rooms contribute to cognitive complexity and, thus, to the probability of human error. Research shows that reaction time increases and response accuracy decreases as the number of elements in the display screen increase. However, in terms of supporting the control room operator, approaches focusing on addressing display complexity solely in terms of information density and its location and patterning, will fall short of delivering a properly designed interface. This paper argues that information complexity and semantic complexity are mandatory components when considering display complexity and that the addition of these concepts assists in understanding and resolving differences between designers and the preferences and performance of operators. This paper concludes that a number of simplified methods, when combined, can be used to estimate the impact that a particular display may have on the operator's ability to perform a function accurately and effectively. We present a mixed qualitative and quantitative approach and a method for complexity estimation

  16. 14 CFR 147.39 - Display of certificate.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Display of certificate. 147.39 Section 147...) SCHOOLS AND OTHER CERTIFICATED AGENCIES AVIATION MAINTENANCE TECHNICIAN SCHOOLS Operating Rules § 147.39 Display of certificate. Each holder of an aviation maintenance technician school certificate and ratings...

  17. A ROOT based event display software for JUNO

    Science.gov (United States)

    You, Z.; Li, K.; Zhang, Y.; Zhu, J.; Lin, T.; Li, W.

    2018-02-01

    An event display software SERENA has been designed for the Jiangmen Underground Neutrino Observatory (JUNO). The software has been developed in the JUNO offline software system and is based on the ROOT display package EVE. It provides an essential tool to display detector and event data for better understanding of the processes in the detectors. The software has been widely used in JUNO detector optimization, simulation, reconstruction and physics study.

  18. The role of national identity representation in the relation between in-group identification and out-group derogation: Ethnic versus civic representation

    OpenAIRE

    Meeus, Joke; Duriez, Bart; Vanbeselaere, Norbert; Boen, Filip

    2010-01-01

    Two studies investigated whether the content of in-group identity affects the relation between in-group identification and ethnic prejudice. The first study among university students, tested whether national identity representations (i.e. ethnic vs. civic) moderate or mediate the relation between Flemish in-group identification and ethnic prejudice. A moderation hypothesis is supported when those higher in identification who subscribe to a more ethnic representation display higher ethnic prej...

  19. Liquid Crystal Microlenses for Autostereoscopic Displays

    Directory of Open Access Journals (Sweden)

    José Francisco Algorri

    2016-01-01

    Full Text Available Three-dimensional vision has acquired great importance in the audiovisual industry in the past ten years. Despite this, the first generation of autostereoscopic displays failed to generate enough consumer excitement. Some reasons are little 3D content and performance issues. For this reason, an exponential increase in three-dimensional vision research has occurred in the last few years. In this review, a study of the historical impact of the most important technologies has been performed. This study is carried out in terms of research manuscripts per year. The results reveal that research on spatial multiplexing technique is increasing considerably and today is the most studied. For this reason, the state of the art of this technique is presented. The use of microlenses seems to be the most successful method to obtain autostereoscopic vision. When they are fabricated with liquid crystal materials, extended capabilities are produced. Among the numerous techniques for manufacturing liquid crystal microlenses, this review covers the most viable designs for its use in autostereoscopic displays. For this reason, some of the most important topologies and their relation with autostereoscopic displays are presented. Finally, the challenges in some recent applications, such as portable devices, and the future of three-dimensional displays based on liquid crystal microlenses are outlined.

  20. Cohort study investigating the effects of first stage of the English tobacco point-of-sale display ban on awareness, susceptibility and smoking uptake among adolescents.

    Science.gov (United States)

    Bogdanovica, Ilze; McNeill, Ann; Britton, John

    2017-01-23

    A prospective evaluation of the effect of 2012 point-of-sale (PoS) display ban in supermarkets in England on perceived exposure to PoS displays, and on changes in susceptibility and smoking uptake among young people. Cohort study. Seven schools in Nottinghamshire, England. 1035 11-16-year-old school children. Changes in reported exposure to PoS displays before and after prohibition, and the association between exposure to and awareness of PoS displays and change in susceptibility to smoking and smoking status between 2011 and 2012 (before the ban) and 2012 and 2013 (after the ban). The proportion of children noticing tobacco PoS displays in supermarkets most or every time they visited a shop changed little between 2011 and 2012 (59.6% (95% CI 56.6% to 62.6%) and 58.8% (95% CI 55.8% to 61.8%), respectively); but decreased by about 13 percentage points to 45.7% (95% CI 42.7% to 48.7%) in 2013, after the ban. However, after adjusting for confounders, implementation of the first stage of the PoS ban in 2012 did not result in significant changes in the relation between susceptibility to smoking and smoking status and exposure to and awareness of PoS displays. Prohibition of PoS in large supermarkets resulted in a decline in the proportion of young people noticing PoS displays in large shops, but little or no change in smoking uptake or susceptibility. It remains to be seen whether extension of the PoS ban to all shops in 2015 has a more marked effect. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  1. A wearable navigation display can improve attentiveness to the surgical field.

    Science.gov (United States)

    Stewart, James; Billinghurst, Mark

    2016-06-01

    Surgical navigation is typically shown on a computer display that is distant from the patient, making it difficult for the surgeon to watch the patient while performing a guided task. We investigate whether a light-weight, untracked, wearable display (such as Google Glass, which has the same size and weight as corrective glasses) can improve attentiveness to the surgical field in a simulated surgical task. Three displays were tested: a computer monitor; a peripheral display above the eye; and a through-the-lens display in front of the eye. Twelve subjects performed a task to position and orient a tracked tool on a plastic femur. Both wearable displays were tested on the dominant and non-dominant eyes of each subject. Attentiveness during the task was measured by the time taken to respond to randomly illuminated LEDs on the femur. Attentiveness was improved with the wearable displays at the cost of a decrease in accuracy. The through-the-lens display performed better than the peripheral display. The peripheral display performed better when on the dominant eye, while the through-the-lens display performed better when on the non-dominant eye. Attentiveness to the surgical field can be improved with the use of a light-weight, untracked, wearable display. A through-the-lens display performs better than a peripheral display, and both perform better than a computer monitor. Eye dominance should be considered when positioning the display.

  2. Evaluation of technical design of advanced information display(III)

    International Nuclear Information System (INIS)

    Cha, Woo Chang; Jung, Sung Hae; Park, Joon Yong; Kim, Nam Cheol; Park, Soon Hyuk

    2005-02-01

    As the computer technology is highly developed, the mental model of computer users including NPP operators has been changed from analogue display type-based stereotype to digitalized one. Therefore, it is necessary and confident to consider the issues to evaluate system suitability of advanced information display on visual display terminal. This document is intended for providing an updated and expanded set of user-interface guidelines that meet the needs of designing digitalized information display by finding the generic guidelines involving information display design issues, and the relationship among the guidelines. The design issues and resolutions from the finding may provide the cues for the designers and evaluators of the specific man machine interfaces of digitalized devices. The Design Review Supporting System for Advanced Information Display(DReSS-AID) was developed for the practical usage of evaluators-in-field, which was implemented with Hangul version guidelines

  3. Evaluation of technical design of advanced information display(III)

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Woo Chang; Jung, Sung Hae; Park, Joon Yong; Kim, Nam Cheol [Kumoh National Institute of Technology, Gumi (Korea, Republic of); Park, Soon Hyuk [DNT Inc., Daejeon (Korea, Republic of)

    2005-02-15

    As the computer technology is highly developed, the mental model of computer users including NPP operators has been changed from analogue display type-based stereotype to digitalized one. Therefore, it is necessary and confident to consider the issues to evaluate system suitability of advanced information display on visual display terminal. This document is intended for providing an updated and expanded set of user-interface guidelines that meet the needs of designing digitalized information display by finding the generic guidelines involving information display design issues, and the relationship among the guidelines. The design issues and resolutions from the finding may provide the cues for the designers and evaluators of the specific man machine interfaces of digitalized devices. The Design Review Supporting System for Advanced Information Display(DReSS-AID) was developed for the practical usage of evaluators-in-field, which was implemented with Hangul version guidelines.

  4. Varifocal mirror display of organ surfaces from CT scans

    International Nuclear Information System (INIS)

    Pizer, S.M.; Fuchs, H.; Bloomberg, S.H.; Li Ching Tsai; Heinz, E.R.

    1982-01-01

    A means will be presented of constructing a powerful varifocal mirror 3D display system with limited cost based on an ordinary color video digital display system. The importance of dynamic interactive control of the display of these images will be discussed; in particular, the design and usefulness of a method allowing real-time user-controlled motion of the 3D object being displayed will be discussed. Also, an effective method will be described of presenting images made of surfaces by the straightforward, automatic calculation of 3D edge strength, the ordering of the resulting voxels by edge strength, and the 3D grey-scale display of the top voxels on this ordered list. The application of these ideas to the 3D display of the intimal wall of the region of bifurcation of the carotid artery from 12-24 CT scans of the neck will be discussed

  5. 75 FR 6079 - Culturally Significant Objects Imported for Exhibition

    Science.gov (United States)

    2010-02-05

    ... cultural significance. The objects are imported pursuant to loan agreements with the foreign owners or custodians. I also determine that the exhibition or display of the exhibit objects at the Yale Center for... Professional and Cultural Exchanges, Bureau of Educational and Cultural Affairs, Department of State. [FR Doc...

  6. A programmable display layer for virtual reality system architectures

    NARCIS (Netherlands)

    Smit, F.A.; Liere, van R.; Fröhlich, B.

    2010-01-01

    Display systems typically operate at a minimum rate of 60 Hz. However, existing VR-architectures generally produce application updates at a lower rate. Consequently, the display is not updated by the application every display frame. This causes a number of undesirable perceptual artifacts. We

  7. DUMA - a program to display distributions in hexagonal geometry

    International Nuclear Information System (INIS)

    Tran Quoc Dung; Makai, M.

    1987-09-01

    DUMA program displays hexagonal structures applied in WWER-440 reactors or one or two distributions in them. It helps users to display either integer, literal or real arrays in an arbitrary hexagonal structure. Possible applications: displaying reactor core layout, power distribution or activity measurements. (author)

  8. Prize for Industrial Applications of Physics: Reflective Cholesteric Liquid Crystals - Innovations in Materials, Display Technology, and Commercialization

    Science.gov (United States)

    Khan, Asad

    Reflective Cholesteric Liquid Crystals have been the subject of much research, development, and commercialization - in display technology as well as other embodiments, such as sensors, privacy films, etc. The liquid Crystal Institute (LCI) at Kent State University (KSU) served as a hot bed of much of the research and development in this field in the early 1990's. From here, the reflective technology was licensed to Kent Displays (KDI) to further develop and commercialize. The 90's saw some development in flexible technologies, drive scheme, display design, as well as materials. The early part of the century took a turn with a strong effort in encapsulation based flexible display development. In 2006, KDI engineers and technologists started firming up ambitious plans for the world's first roll-to-roll manufacturing line for bistable cholesteric displays. In 2009, this became a reality! In early 2010, the first eWriter product was launched into the consumer market under the brand Boogie Board®. Within months, this became a success forcing the rapid development of the manufacturing process for the flexible displays. Today, the company has two manufacturing lines, 24 hour roll-to-roll production of flexible displays, millions of Boogie Board products in the global market place, and a growing OEM business in the Boogie Board technology. KDI continues to do basic research, development, and exploration in the bistable display field. It also has had to become an expert in the supply chain management of the unique raw materials needed for flexible display manufacturing, while still managing global operations with sales offices in several continents and a growing and diversified group of individuals. In this presentation, we will present the story, research, development, technology, and latest trends in bistable cholesteric liquid crystal materials with a particular emphasis on the eWriter technology and market.

  9. Investigating the relationship between emotional displays of nursing managers and the performance of nursing staff (Case study: Dr. Shariati Hospital, Tehran

    Directory of Open Access Journals (Sweden)

    Zahra Riahi Paghaleh

    2016-07-01

    Full Text Available Emotional display is the management and proper expression of correct emotions consistent with organizational and profession rules. One of the factors affecting the occupational performance is the skills of the managers in control and effective use of excitement. The present study was conducted to determine the relationship between nursing managers' emotional display and the performance of nursing staff. The study population consisted of all managers and nursing staff of Shariati Hospital, Tehran in 2015 who were selected using census method. The instruments were Dindorf et al. emotional display questionnaire and Paterson's job performance questionnaire whose validity and reliability were confirmed. Data were analyzed with Spearman correlation Coefficient, independent t-test, and ANOVA using SPSS software. "Real-emotion display" of nursing managers had a significant correlation with nursing staff performance (P=0.02, r=0.203. But "superficial and deep display of emotions" of the managers did not. There were no significant correlations between emotional display with age and work experience in managers and between job performance with marital status, gender, and age and work experience in nursing staff (P>0.05. The results showed that design and mplementation of training courses about emotional display are necessary in managers in order to improve the job performance of nursing staff.

  10. Impact of removing point-of-sale tobacco displays: data from a New Zealand youth survey.

    Science.gov (United States)

    Edwards, Richard; Ajmal, Ali; Healey, Benjamin; Hoek, Janet

    2017-07-01

    The tobacco industry increasingly invests in point-of-sale (POS) marketing. In July 2012, New Zealand required the removal of POS tobacco displays concurrently with increased enforcement and penalties for selling tobacco to minors, and additional restrictions on tobacco sponsorship. We evaluated the impact of these measures using a before-after study. We analysed data from annual surveys of more than 25 000 year 10 (14-15 years) students from 2007 and 2011 to 2014. Measures included prevalence of smoking-related behaviours and strength of association between visiting tobacco-retailing stores and smoking behaviours. Between 2011 and 2014, smoking experimentation (had smoked ever but smoked less than monthly currently) decreased from 23% in 2011 to 17% in 2014 (adjusted odds ratio (aOR) 0.73, 95% CI 0.69 to 0.78); current smoking (at least monthly) prevalence from 9% to 7% (aOR 0.71, 0.64 to 0.79) and initiation in the last year from 13% to 11% (aOR 0.91, 0.84 to 0.98). Attempted purchase of cigarettes in the past 30 days among smokers decreased from 30% in 2012 to 26% in 2013 (aOR 0.77, 0.63 to 0.91). Positive associations between frequency of visiting tobacco-retailing stores and smoking-related behaviours weakened post-implementation. The introduction of a POS display ban and concurrent measures was followed by significant reductions in initiation, experimental and regular smoking, attempted purchase of cigarettes, and reduced association between visiting tobacco-retailing stores and smoking behaviours. The findings suggest that POS display bans are important components of strategies to reduce smoking initiation among youth and young people. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  11. Thermoluminescence emission spectrometry of glass display in mobile phones and resulting evaluation of the dosimetric properties of a specific type of display glass

    International Nuclear Information System (INIS)

    Discher, Michael; Woda, Clemens

    2014-01-01

    Glass displays of mobile phones are sensitive to ionizing radiation and can be used for retrospective dosimetry for the purpose of triage after a radiological accident or attack. In this study the two main types of glass display that are used in modern mobile phones were investigated using thermoluminescence (TL) emission spectrometry. A different TL spectrum was observed for the glass display of category A (lime-aluminosilicate glass) and category B (boron-silicate glass). Based on the spectral measurements an optimized detection window was chosen to re-evaluate the dosimetric properties (dose response, optical and long-term stability) of glass display category B. - Highlights: • Two display glass types show similar TL emission peaks but with strongly different relative intensities. • The intrinsic background TL signal peaks at similar wavelengths as the radiation induced signal. • Dosimetric properties of one display glass type were re-evaluated using an optimized detection window

  12. Service level status-a new real-time status display for IT services

    Energy Technology Data Exchange (ETDEWEB)

    Lopienski, S [IT Department, FIO group CERN, European Organization for Nuclear Research, 1211 Geneve 23 (Switzerland)], E-mail: Sebastian.Lopienski@cern.ch

    2008-07-15

    Nowadays, IT departments provide, and people use, computing services of an increasingly heterogeneous nature. There is thus a growing need for a status display that groups these different services and reports their status and availability in a uniform way. The Service Level Status (SLS) system addresses these needs by providing a web-based display that dynamically shows availability, basic information and statistics about various IT services, as well as the dependencies between them. This paper first introduces the requirements SLS had to meet, and the main concepts behind it, like service availability and status, Key Performance Indicators (KPIs), sub/meta-services, and service dependencies. It then describes the SLS system architecture, and some interesting implementation details, such as the usage of XML Schemas. Since clear visualization of service availability and status is one of the main goals of SLS, emphasis is put on describing the intuitive web-based user interface.

  13. Service level status-a new real-time status display for IT services

    International Nuclear Information System (INIS)

    Lopienski, S

    2008-01-01

    Nowadays, IT departments provide, and people use, computing services of an increasingly heterogeneous nature. There is thus a growing need for a status display that groups these different services and reports their status and availability in a uniform way. The Service Level Status (SLS) system addresses these needs by providing a web-based display that dynamically shows availability, basic information and statistics about various IT services, as well as the dependencies between them. This paper first introduces the requirements SLS had to meet, and the main concepts behind it, like service availability and status, Key Performance Indicators (KPIs), sub/meta-services, and service dependencies. It then describes the SLS system architecture, and some interesting implementation details, such as the usage of XML Schemas. Since clear visualization of service availability and status is one of the main goals of SLS, emphasis is put on describing the intuitive web-based user interface

  14. Infertility diagnosis has a significant impact on the transcriptome of developing blastocysts.

    Science.gov (United States)

    McCallie, Blair R; Parks, Jason C; Griffin, Darren K; Schoolcraft, William B; Katz-Jaffe, Mandy G

    2017-08-01

    Is the human blastocyst transcriptome associated with infertility diagnosis, specifically: polycystic ovaries (PCO), male factor (MF) and unexplained (UE)? The global blastocyst transcriptome was significantly altered in association with a PCO, MF and UE infertility diagnosis. Infertility diagnosis has an impact on the probability for a successful outcome following an IVF cycle. Limited information is known regarding the relationship between a specific infertility diagnosis and blastocyst transcription during preimplantation development. Blastocysts created during infertility treatment from patients with specific infertility diagnoses (PCO, MF and UE) were analyzed for global transcriptome compared to fertile donor oocyte blastocysts (control). Surplus cryopreserved blastocysts were donated with patient consent and institutional review board approval. Female patients were infertility diagnosis: PCO (n = 50), MF (n = 50), UE (n = 50) and fertile donor oocyte controls (n = 50). Pooled blastocysts were lysed for RNA isolation followed by microarray analysis using the SurePrint G3 Human Gene Expression Microarray. Validation was performed on significant genes of interest using real-time quantitative PCR (RT-qPCR). Transcription alterations were observed for all infertility etiologies compared to controls, resulting in differentially expressed genes: PCO = 869, MF = 348 and UE = 473 (P 2-fold). Functional annotation of biological and molecular processes revealed both similarities, as well as differences, across the infertility groups. All infertility etiologies displayed transcriptome alterations in signal transducer activity, receptor binding, reproduction, cell adhesion and response to stimulus. Blastocysts from PCO patients were also enriched for apoptotic genes while MF blastocysts displayed enrichment for genes involved in cancer processes. Blastocysts from couples with unexplained infertility displayed transcription alterations related to various disease states

  15. Assessment of display performance for medical imaging systems: Executive summary of AAPM TG18 report

    International Nuclear Information System (INIS)

    Samei, Ehsan; Badano, Aldo; Chakraborty, Dev

    2005-01-01

    Digital imaging provides an effective means to electronically acquire, archive, distribute, and view medical images. Medical imaging display stations are an integral part of these operations. Therefore, it is vitally important to assure that electronic display devices do not compromise image quality and ultimately patient care. The AAPM Task Group 18 (TG18) recently published guidelines and acceptance criteria for acceptance testing and quality control of medical display devices. This paper is an executive summary of the TG18 report. TG18 guidelines include visual, quantitative, and advanced testing methodologies for primary and secondary class display devices. The characteristics, tested in conjunction with specially designed test patterns (i.e., TG18 patterns), include reflection, geometric distortion, luminance, the spatial and angular dependencies of luminance, resolution, noise, glare, chromaticity, and display artifacts. Geometric distortions are evaluated by linear measurements of the TG18-QC test pattern, which should render distortion coefficients less than 2%/5% for primary/secondary displays, respectively. Reflection measurements include specular and diffuse reflection coefficients from which the maximum allowable ambient lighting is determined such that contrast degradation due to display reflection remains below a 20% limit and the level of ambient luminance (L amb ) does not unduly compromise luminance ratio (LR) and contrast at low luminance levels. Luminance evaluation relies on visual assessment of low contrast features in the TG18-CT and TG18-MP test patterns, or quantitative measurements at 18 distinct luminance levels of the TG18-LN test patterns. The major acceptable criteria for primary/secondary displays are maximum luminance of greater than 170/100 cd/m 2 , LR of greater than 250/100, and contrast conformance to that of the grayscale standard display function (GSDF) of better than 10%/20%, respectively. The angular response is tested to

  16. Modeling LCD Displays with Local Backlight Dimming for Image Quality Assessment

    DEFF Research Database (Denmark)

    Korhonen, Jari; Burini, Nino; Forchhammer, Søren

    2011-01-01

    for evaluating the signal quality distortion related directly to digital signal processing, such as compression. However, the physical characteristics of the display device also pose a significant impact on the overall perception. In order to facilitate image quality assessment on modern liquid crystaldisplays...... (LCD) using light emitting diode (LED) backlight with local dimming, we present the essential considerations and guidelines for modeling the characteristics of displays with high dynamic range (HDR) and locally adjustable backlight segments. The representation of the image generated by the model can...... be assessed using the traditional objective metrics, and therefore the proposed approach is useful for assessing the performance of different backlight dimming algorithms in terms of resulting quality and power consumption in a simulated environment. We have implemented the proposed model in C++ and compared...

  17. Smart TV-Smartphone Multiscreen Interactive Middleware for Public Displays.

    Science.gov (United States)

    Martinez-Pabon, Francisco; Caicedo-Guerrero, Jaime; Ibarra-Samboni, Jhon Jairo; Ramirez-Gonzalez, Gustavo; Hernández-Leo, Davinia

    2015-01-01

    A new generation of public displays demands high interactive and multiscreen features to enrich people's experience in new pervasive environments. Traditionally, research on public display interaction has involved mobile devices as the main characters during the use of personal area network technologies such as Bluetooth or NFC. However, the emergent Smart TV model arises as an interesting alternative for the implementation of a new generation of public displays. This is due to its intrinsic connection capabilities with surrounding devices like smartphones or tablets. Nonetheless, the different approaches proposed by the most important vendors are still underdeveloped to support multiscreen and interaction capabilities for modern public displays, because most of them are intended for domestic environments. This research proposes multiscreen interactive middleware for public displays, which was developed from the principles of a loosely coupled interaction model, simplicity, stability, concurrency, low latency, and the usage of open standards and technologies. Moreover, a validation prototype is proposed in one of the most interesting public display scenarios: the advertising.

  18. Latency requirements for head-worn display S/EVS applications

    Science.gov (United States)

    Bailey, Randall E.; Arthur, Jarvis J., III; Williams, Steven P.

    2004-08-01

    NASA's Aviation Safety Program, Synthetic Vision Systems Project is conducting research in advanced flight deck concepts, such as Synthetic/Enhanced Vision Systems (S/EVS), for commercial and business aircraft. An emerging thrust in this activity is the development of spatially-integrated, large field-of-regard information display systems. Head-worn or helmet-mounted display systems are being proposed as one method in which to meet this objective. System delays or latencies inherent to spatially-integrated, head-worn displays critically influence the display utility, usability, and acceptability. Research results from three different, yet similar technical areas - flight control, flight simulation, and virtual reality - are collectively assembled in this paper to create a global perspective of delay or latency effects in head-worn or helmet-mounted display systems. Consistent definitions and measurement techniques are proposed herein for universal application and latency requirements for Head-Worn Display S/EVS applications are drafted. Future research areas are defined.

  19. Looking forward: In-vehicle auxiliary display positioning affects carsickness.

    Science.gov (United States)

    Kuiper, Ouren X; Bos, Jelte E; Diels, Cyriel

    2018-04-01

    Carsickness is associated with a mismatch between actual and anticipated sensory signals. Occupants of automated vehicles, especially when using a display, are at higher risk of becoming carsick than drivers of conventional vehicles. This study aimed to evaluate the impact of positioning of in-vehicle displays, and subsequent available peripheral vision, on carsickness of passengers. We hypothesized that increased peripheral vision during display use would reduce carsickness. Seated in the front passenger seat 18 participants were driven a 15-min long slalom on two occasions while performing a continuous visual search-task. The display was positioned either at 1) eye-height in front of the windscreen, allowing peripheral view on the outside world, and 2) the height of the glove compartment, allowing only limited view on the outside world. Motion sickness was reported at 1-min intervals. Using a display at windscreen height resulted in less carsickness compared to a display at glove compartment height. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Nucleic acid secondary structure prediction and display.

    OpenAIRE

    Stüber, K

    1986-01-01

    A set of programs has been developed for the prediction and display of nucleic acid secondary structures. Information from experimental data can be used to restrict or enforce secondary structural elements. The predictions can be displayed either on normal line printers or on graphic devices like plotters or graphic terminals.