Sample records for grounding rod clamp

  1. The deformation of an elastic rod with a clamp sliding along a smooth and curved profile

    CERN Document Server

    Misseroni, D; Zaccaria, D; Bigoni, D

    2015-01-01

    The design of compliant mechanisms is crucial in several technologies and relies on the availability of solutions for nonlinear structural problems. One of these solutions is given and experimentally validated in the present article for a compliant mechanism moving along a smooth curved profile. In particular, a deformable elastic rod is held by two clamps, one at each end. The first clamp is constrained to slide without friction along a curved profile, while the second clamp moves in a straight line transmitting its motion through the elastic rod to the first clamp. For this system it is shown that the clamp sliding on the profile imposes nontrivial boundary conditions (derived via a variational and an asymptotic approach), which strongly influence buckling and nonlinear structural behaviour. Investigation of this behaviour shows that a compliant mechanism can be designed, which gives an almost neutral response in compression. This behavior could easily be exploited to make a force limiting device. Finally a...

  2. Evaluation of Grounding Impedance of a Complex Lightning Protective System Using Earth Ground Clamp Measurements and ATP Modeling

    Science.gov (United States)

    Mata, Carlos T.; Rakov, V. A.; Mata, Angel G.

    2010-01-01

    A new Lightning Protection System (LPS) was designed and built at Launch Complex 39B (LC39B), at the Kennedy Space Center (KSC), Florida, which consists of a catenary wire system (at a height of about 181 meters above ground level) supported by three insulators installed atop three towers in a triangular configuration. A total of nine downconductors (each about 250 meters long, on average) are connected to the catenary wire system. Each of the nine downconductors is connected to a 7.62-meter radius circular counterpoise conductor with six equally spaced 6-meter long vertical grounding rods. Grounding requirements at LC39B call for all underground and above ground metallic piping, enclosures, raceways, and cable trays, within 7.62 meters of the counterpoise, to be bounded to the counterpoise, which results in a complex interconnected grounding system, given the many metallic piping, raceways, and cable trays that run in multiple direction around LC39B. The complexity of this grounding system makes the fall of potential method, which uses multiple metallic rods or stakes, unsuitable for measuring the grounding impedances of the downconductors. To calculate the downconductors grounding impedance, an Earth Ground Clamp (a stakeless grounding resistance measuring device) and a LPS Alternative Transient Program (ATP) model are used. The Earth Ground Clamp is used to measure the loop impedance plus the grounding impedance of each downconductor and the ATP model is used to calculate the loop impedance of each downconductor circuit. The grounding impedance of the downconductors is then calculated by subtracting the ATP calculated loop impedances from the Earth Ground Clamp measurements.

  3. RESULTS OF TESTS OF LIGHTNING-RODS WITH UNIVERSAL CLAMPS BY THE APERIODIC IMPULSES OF CURRENT OF ARTIFICIAL LIGHTNING WITH THE PEAK-TEMPORAL PARAMETERS RATIONED ON FOREIGN STANDARDS

    Directory of Open Access Journals (Sweden)

    M.I. Baranov

    2015-06-01

    Full Text Available Purpose. Test in obedience to the requirements of row of operating foreign standards of round metallic lightning-rods with the flat metallic universal clamps of the special type on firmness to direct action of аperiodic impulses of current of temporal form 10/350 μs by amplitude of 50 кА (N− class and 100 кА (H− class. Methodology. The order of leadthrough of these tests is certain the followings normative documents: International IEC 62305-1: 2010, Russian national GOST R IEC 62305-1-2010 and German national DIN EN 50164-1:2008 Standards. Results. Conducted on a powerful high-voltage pulsed current of artificial linear lightning with the peak-temporal parameters and admittances of test rationed on the indicated foreign standards rationed that all of the lightning-rods tested in collection with universal clamps, isolating holders and ceramic elements of roof of technical building were survive electrodynamics and electrothermal action of in-use single short blow of an artificial storm digit. Originality. First in domestic practice the similar model tests of lightning-rods are conducted with universal clamps, executed from different explorer materials, on firmness to flowing to on by it the indicated large impulsive currents of artificial lightning. Practical value. Real firmness to lightning of round copper and zincked steel lightning-rods is certain with the flat copper, zincked steel and non-rusting steel universal clamps of the special execution.

  4. Enhanced static ground power unit based on flying capacitor based h-bridge hybrid active-neutral-point-clamped converter

    DEFF Research Database (Denmark)

    Abarzadeh, Mostafa; Madadi Kojabadi, Hossein; Deng, Fujin

    2016-01-01

    Static power converters have various applications, such as static ground power units (GPUs) for airplanes. This study proposes a new configuration of a static GPU based on a novel nine-level flying capacitor h-bridge active-neutral-point-clamped (FCHB_ANPC) converter. The main advantages...... improvement in GPU dynamic performances. This progress is achieved by utilising the proposed FCHB converter to an ANPC converter and using the suggested modulation method. This leads to diminish the size and cost and enhance the feasibility and reliability of the converter. Applying the proposed modulation...

  5. 一起架空地线悬垂线夹挂轴磨损分析%Case Analysis of Suspension Clamp's Shaft Fracture of Overhead Ground Wire

    Institute of Scientific and Technical Information of China (English)

    黄修乾

    2011-01-01

    To solve the line tripping problem caused by the fracture of shaft on suspension clamp of the overhead ground wire of ihe 220 kV Marwan-Xkiaguan Line I , this paper analyzes (he size, texture of the suspension clamp and excludes the quality defect of suspension clamp, and by studying the line design parameters and plan & cross-section drawings, the geographical terrain and weather condition around the tripping location, the field equipment status, and the stress on suspension clamp, the reason of shaft fracture are discussed, li is concluded that the wind along the direction of line and the small vertical load from the suspension clamp are the main reasons leading to the abrasion of suspension clamp and fracture of the shaft. Countermeasures are proposed as precautions.%为解决220kV漫下I回线因架空地线悬垂线夹挂轴断裂引起的线路跳闸问题,通过分析悬垂线夹的尺寸、材质,排除了悬垂线夹存在质量问题;根据线路设计参数及平断面图、故障点地形及气象环境、故障现场设备状况和悬垂线夹受力情况,分析了挂轴断裂的原因,得出顺线路方向风的作用和悬垂线夹所受垂直荷载小是引起悬垂线夹挂轴磨损、断裂的主要原因,并有针对性的提出了相应防范措施.

  6. 双卡式杆式泵的研制及应用%Development and Application of Double Clamping Rod Pump

    Institute of Scientific and Technical Information of China (English)

    牛彩云; 张宏福; 甘庆明; 李大建

    2014-01-01

    Oil wells in Changqing oilfield buried deep,low single well production.In order to reduce the cost of operation,a set top drum fixed,mechanical,dual card dual seal cup rod pump were de-veloped,basic structure was composed by oil pump,bearing set and blowout preventer.After field application 5 000 wells,the test results show that,the sucker rod pump inspection period is about tube pump 2/3,downhole operation volume tube pump 15%,an oil pipe ratio cases reached 70%. Rod pump structure itself is an important influencing factor.This paper Article from the rod pump support assembly,valve structure and the support assembly and tubing with the size analy-zes three aspects of the cause of failure rod pump,also pointed out that the promotion of rod pump is a very long way,only to achieve standardization,serialization,universal,can really play a rod pump advantage.%长庆油田油井埋藏深、单井产量低,为降低作业成本,研制了定筒式顶部固定、机械与皮碗双密封的双卡式杆式泵。现场应用5000口井,试验结果表明:杆式泵检泵周期约为管式泵的2/3,井下作业总量较管式泵高15%,起油管比例达到70%。杆式泵自身结构是一个重要的影响因素,从杆式泵支撑总成、泵阀结构以及支撑总成与油管配合尺寸3个方面深入剖析了杆式泵产生故障的原因,只有实现了标准化、系列化、通用化,才能真正发挥杆式泵优势。

  7. Experimental study of lightning protection effects to a overhead ground wire by a lightning rod and projection rods; Yuraishin oyobi dosshi wo mochiita kakuchisen no raigai boshi ni kansuru jikkenteki kento

    Energy Technology Data Exchange (ETDEWEB)

    Katsuragi, Y. [Chubu Electric Power Co. Inc., Nagoya (Japan); Aihara, Y. [Central Research Institute of Electric Power Industry, Tokyo (Japan)

    1995-04-20

    The overhead ground wire is generally used on transmission lines as one of the lightning protection devices for the power conductors. In recent years, the ground wire with an optical fiber cable in it (OPGW) has been employed on the transmission systems. The strands of the ground wire are, however, frequently melted down because of lightning strokes to them not only in summer but also in winter. For this reason, it is necessary to devise the new lightning protection method for the ground wire. As the protection method, lightning rods installed on the transmission tower arms and projection rods wound around a ground wire are proposed by authors. Lightning protection effects of these methods are shown by model experiments which simulate summer and winter lightning strokes. It has been made clear that these methods are useful as one of the lightning protection methods for transmission lines, and application conditions of them for practical use are also shown. 4 refs., 12 figs., 2 tabs.

  8. Telescopic drilling rod

    Energy Technology Data Exchange (ETDEWEB)

    Kagan, I.L.; Berezov, S.I.; Gavrilov, G.A.; Goykhman, Ya.A.; Makushkin, D.O.; Rachev, M.P.; Voynich, L.K.

    1981-09-07

    The telescopic drilling rod includes an inner section of the rod, in whose center cable has been passed and is attached a bearing assembly connecting it to the winch, outer section of rod along which there is pipeline connecting the working cavity formed by the inner section of rod and the housing, installed on the lower end of the outer section of rod, with cavity formed by framework of the guide swivel and end piece and connected to the hydraulic system of the machine by pipeline, as well as clamping elements. In order to drill wells to a depth greater than the length of the outer sectrion of the rod, the latter jointly with the inner section of rod is lowered into the extreme lower position until swivel rests on the feed mechanism. With further slipping of cable and the absence of pressure in the hydraulic system, clamping elements do not have an effect on the inner section of rod. It has the opportunity to freely move along the outer section of rod downwards to the face. When pressure is supplied on pipeline into cavity and further through pipeline into working cavity, the inner section of rod is clamped with feed of the outer section in the process of drilling, both sections move jointly. Because of the link between working cavity of sleeve installed on the lower end of the outer section of rod, and the hydraulic system of the machine through the swivel cavity, it is possible to fix the drilling rod in any mutual axial position of the section.

  9. Influence of location of the lead wires on calculation results of grounding transient characteristics of a grounding rod

    Directory of Open Access Journals (Sweden)

    Kuklin D. V.

    2016-12-01

    Full Text Available For calculations and measurements of transient characteristics of groundings, the current and potential lead wires are frequently used accordingly to inject the current into the grounding and find the grounding potential rise (GPR. The results of the calculations and measurements can be dependent on the location of the current and potential lead wires due to mutual influence between them and the grounding wire. It is important to determine to what extent the location of the wires influences the calculation results for the grounding with a simple configuration. Notably, in contrast to the measurements, for the calculations it is possible to locate wires vertically, also the potential lead wire can be replaced by the integral of the electric field. For the calculations the finite difference time domain method (FDTD has been used in the work. In order to estimate to what extent the calculated GPR can be influenced by location of the wires, calculations with different wires locations have been carried out. An analysis of the calculation results has been made. There are calculation methods in which the injection of the current and calculation of the GPR are performed without the current and potential lead wires. The method based on the telegrapher's equations is one of such methods. In order to determine what location of the lead wires gives the same calculation results as those of the method that uses the telegrapher's equations, a comparison of calculation results of two methods has been made. Based on the calculation results it can be concluded that the calculated transient characteristics depend to a different extent on such factors as mutual location of the lead wires and the grounding wire, replacing the potential lead wire by the integral of the electric field, electrical parameters of the soil. Location of one of the lead wires above the grounding wire significantly reduces the calculated GPR. Calculation results for a perpendicular location

  10. To clamp or not to clamp late?

    Directory of Open Access Journals (Sweden)

    Nicoletta Iacovidou

    2013-04-01

    Full Text Available When resuscitating a neonate, one encounters controversial issues and a great deal of confusion. These issues include the question as to when should the umbilical cord be clamped. Clamping and cutting the umbilical cord at birth is the oldest intervention in humans. Even though many aspects of the timing for cord clamping have been clarified, some questions still remain unanswered. If delayed cord clamping is to become a standard approach which timing is the optimal? And depending on the mode of delivery should timing be the same or different for normal vaginal delivery or for caesarean section? What about  the compromised neonate, or the very preterm one? We have more questions than answers. More randomized controlled studies are needed in normal and pathologic neonates, in order to address these questions, before we practice delayed cord clamping with safety for the babies and the mothers.

  11. Photovoltaic panel clamp

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Malcolm P.; Mittan, Margaret Birmingham; Miros, Robert H. J.; Stancel, Robert

    2013-03-19

    A photovoltaic panel clamp includes an upper and lower section. The interface between the assembled clamp halves and the module edge is filled by a flexible gasket material, such as EPDM rubber. The gasket preferably has small, finger like protrusions that allow for easy insertion onto the module edge while being reversed makes it more difficult to remove them from the module once installed. The clamp includes mounting posts or an integral axle to engage a bracket. The clamp also may include a locking tongue to secure the clamp to a bracket.

  12. Photovoltaic panel clamp

    Science.gov (United States)

    Mittan, Margaret Birmingham; Miros, Robert H. J.; Brown, Malcolm P.; Stancel, Robert

    2012-06-05

    A photovoltaic panel clamp includes an upper and lower section. The interface between the assembled clamp halves and the module edge is filled by a flexible gasket material, such as EPDM rubber. The gasket preferably has small, finger like protrusions that allow for easy insertion onto the module edge while being reversed makes it more difficult to remove them from the module once installed. The clamp includes mounting posts or an integral axle to engage a bracket. The clamp also may include a locking tongue to secure the clamp to a bracket.

  13. Radial wedge flange clamp

    Science.gov (United States)

    Smith, Karl H.

    2002-01-01

    A radial wedge flange clamp comprising a pair of flanges each comprising a plurality of peripheral flat wedge facets having flat wedge surfaces and opposed and mating flat surfaces attached to or otherwise engaged with two elements to be joined and including a series of generally U-shaped wedge clamps each having flat wedge interior surfaces and engaging one pair of said peripheral flat wedge facets. Each of said generally U-shaped wedge clamps has in its opposing extremities apertures for the tangential insertion of bolts to apply uniform radial force to said wedge clamps when assembled about said wedge segments.

  14. Lightning rod ionizing natural ionca - Ionic electrode active trimetallictriac of grounding - Definitive and total solution against 'blackouts' and electrical faults generated by atmospheric charges (lightning)

    Energy Technology Data Exchange (ETDEWEB)

    Cabareda, Luis

    2010-09-15

    The Natural Ionizing System of Electrical Protection conformed by: Lightning Rod Ionizing Natural Ionca and Ionic Electrode Active Trimetallic Triac of Grounding offers Total Protection, Maximum Security and Zero Risk to Clinics, Hospitals, Integral Diagnostic Center, avoiding ''the burning'' of Electronics Cards; Refineries, Tanks and Stations of Fuel Provision; Electrical Substations, Towers and Transmission Lines with transformer protection, motors, elevators, A/C, mechanicals stairs, portable and cooling equipment, electrical plants, others. This New High Technology is the solution to the paradigm of Benjamin Franklin and it's the mechanism to end the 'Blackouts' that produces so many damages and losses throughout the world.

  15. Morphoelastic rods

    CERN Document Server

    Tiero, Alessandro

    2014-01-01

    We propose a mechanical theory describing elastic rods which, like plant organs, can grow and can change their intrinsic curvature and torsion. The equations ruling accretion and remodeling are obtained by combining balance laws involving non-standard forces with constitutive prescriptions filtered by a dissipation principle that takes into account both standard and non-standard working.

  16. CONTROL ROD

    Science.gov (United States)

    Zinn, W.H.; Ross, H.V.

    1958-11-18

    A control rod is described for a nuclear reactor. In certaln reactor designs it becomes desirable to use a control rod having great width but relatively llttle thickness. This patent is addressed to such a need. The neutron absorbing material is inserted in a triangular tube, leaving volds between the circular insert and the corners of the triangular tube. The material is positioned within the tube by the use of dummy spacers to achleve the desired absorption pattern, then the ends of the tubes are sealed with suitable plugs. The tubes may be welded or soldered together to form two flat surfaces of any desired width, and covered with sheetmetal to protect the tubes from damage. This design provides a control member that will not distort under the action of outside forces or be ruptured by gases generated within the jacketed control member.

  17. Management of umbilical cord clamping.

    Science.gov (United States)

    Webbon, Lucy

    2013-02-01

    The Royal College of Midwives (RCM) has updated its third stage of labour guidelines (RCM 2012) to be clearly supportive of a delay in umbilical cord clamping, although specific guidance on timing is yet to be announced. It is therefore imperative that both midwives and student midwives understand and are able to integrate delaying into their practice, as well as communicating to women the benefits; only in this way can we give women fully informed choices on this aspect of care. The main benefit of delayed cord clamping is the protection it can provide in reducing childhood anaemia, which is a major issue, especially in poorer countries. A review of the evidence found no risks linked to delayed clamping, and no evidence that it cannot be used in combination with the administration of uterotonic drugs. Delayed cord clamping can be especially beneficial for pre term and compromised babies.

  18. Robotic Partial Nephrectomy Using Robotic Bulldog Clamps

    OpenAIRE

    2011-01-01

    Background and Objectives: The need for a skilled assistant to perform hilar clamping during robotic partial nephrectomy is a potential limitation of the technique. We describe our experience using robotic bulldog clamps applied by the console surgeon for hilar clamping. Methods: A total of 60 consecutive patients underwent robotic partial nephrectomy, 30 using laparoscopic bulldog clamps applied by the assistant and 30 using robotic bulldog clamps applied with the robotic Prograsp instrument...

  19. Clamp wins pipe repair prize

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2001-04-01

    This paper describes the permanent pipeline repair system, developed by Tekmar, which is powered by seawater hydraulics and is easily installed and tested by any workclass remotely operated vehicle (rov). Details are given of the two main components of the system, namely, the diverless high pressure split repair clamp and the rov-operated tool to install it.

  20. Automated planar patch-clamp.

    Science.gov (United States)

    Milligan, Carol J; Möller, Clemens

    2013-01-01

    Ion channels are integral membrane proteins that regulate the flow of ions across the plasma membrane and the membranes of intracellular organelles of both excitable and non-excitable cells. Ion channels are vital to a wide variety of biological processes and are prominent components of the nervous system and cardiovascular system, as well as controlling many metabolic functions. Furthermore, ion channels are known to be involved in many disease states and as such have become popular therapeutic targets. For many years now manual patch-clamping has been regarded as one of the best approaches for assaying ion channel function, through direct measurement of ion flow across these membrane proteins. Over the last decade there have been many remarkable breakthroughs in the development of technologies enabling the study of ion channels. One of these breakthroughs is the development of automated planar patch-clamp technology. Automated platforms have demonstrated the ability to generate high-quality data with high throughput capabilities, at great efficiency and reliability. Additional features such as simultaneous intracellular and extracellular perfusion of the cell membrane, current clamp operation, fast compound application, an increasing rate of parallelization, and more recently temperature control have been introduced. Furthermore, in addition to the well-established studies of over-expressed ion channel proteins in cell lines, new generations of planar patch-clamp systems have enabled successful studies of native and primary mammalian cells. This technology is becoming increasingly popular and extensively used both within areas of drug discovery as well as academic research. Many platforms have been developed including NPC-16 Patchliner(®) and SyncroPatch(®) 96 (Nanion Technologies GmbH, Munich), CytoPatch™ (Cytocentrics AG, Rostock), PatchXpress(®) 7000A, IonWorks(®) Quattro and IonWorks Barracuda™, (Molecular Devices, LLC); Dynaflow(®) HT (Cellectricon

  1. Multifrequency Excitation of a Clamped-Clamped Microbeam

    KAUST Repository

    Jaber, Nizar R.

    2016-01-20

    We present analytical and experimental investigation of an electrically actuated clamped-clamped microbeam under a twosource harmonic excitation. The first frequency is swept around the first mode of vibration where the second one is fixed. These microbeams are fabricated using polyimide as structural layer coated with nickel form top and chromium and gold layers from bottom. We demonstrate the excitation of additive and subtractive type resonance. We show that by properly tuning the frequency and the amplitude of the excitation force, the frequency bandwidth of the resonator is increased. Theoretically, we solved the eigenvalue problem for different axial forces to find the natural frequencies ratio that match the experimental values. Using Galerkin method, a reduced order model is derived to simulate the static and dynamic response of the device where using three symmetric mode shapes provided a good agreement with experimental data. © Copyright 2015 by ASME.

  2. Tie rod insertion test

    CERN Multimedia

    B. LEVESY

    2002-01-01

    The superconducting coil is inserted in the outer vaccum tank and supported by a set of tie rods. These tie rods are made of titanium alloy. This test reproduce the final insertion of the tie rods inside the outer vacuum tank.

  3. Analysis list: Clamp [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Clamp Cell line + dm3 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/target/Clamp.1....tsv http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/target/Clamp.5.tsv http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/target/Clam...p.10.tsv http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/colo/Clamp.Cell_line.tsv http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/colo/Cell_line.gml ...

  4. Is early cord clamping, delayed cord clamping or cord milking best?

    Science.gov (United States)

    Vatansever, Binay; Demirel, Gamze; Ciler Eren, Elif; Erel, Ozcan; Neselioglu, Salim; Karavar, Hande Nur; Gundogdu, Semra; Ulfer, Gozde; Bahadir, Selcen; Tastekin, Ayhan

    2017-03-20

    To compare the antioxidant status of three cord clamping procedures (early clamping, delayed clamping and milking) by analyzing the thiol-disulfide balance. This randomized controlled study enrolled 189 term infants who were divided into three groups according to the cord clamping procedure: early clamping, delayed clamping and milking. Blood samples were collected from the umbilical arteries immediately after clamping, and the thiol/disulfide homeostasis was analyzed. The native and total thiol levels were significantly (p cord clamping group compared with the other two groups. The disulfide/total thiol ratio was significantly (p = .026) lower in the delayed cord clamping and milking groups compared with the early clamping groups. Early cord clamping causes the production of more disulfide bonds and lower thiol levels, indicating that oxidation reactions are increased in the early cord clamping procedure compared with the delayed cord clamping and milking procedures. The oxidant capacity is greater with early cord clamping than with delayed clamping or cord milking. Delayed cord clamping or milking are beneficial in neonatal care, and we suggest that they be performed routinely in all deliveries.

  5. Delayed umbilical cord clamping in premature neonates.

    Science.gov (United States)

    Kaempf, Joseph W; Tomlinson, Mark W; Kaempf, Andrew J; Wu, YingXing; Wang, Lian; Tipping, Nicole; Grunkemeier, Gary

    2012-08-01

    Delayed umbilical cord clamping is reported to increase neonatal blood volume. We estimated the clinical outcomes in premature neonates who had delayed umbilical cord clamping compared with a similar group who had early umbilical cord clamping. This was a before-after investigation comparing early umbilical cord clamping with delayed umbilical cord clamping (45 seconds) in two groups of singleton neonates, very low birth weight (VLBW) (401-1,500 g) and low birth weight (LBW) (greater than 1,500 g but less than 35 weeks gestation). Neonates were excluded from delayed umbilical cord clamping if they needed immediate major resuscitation. Primary outcomes were provision of delivery room resuscitation, hematocrit, red cell transfusions, and the principle Vermont Oxford Network outcomes. In VLBW neonates (77 delayed umbilical cord clamping, birth weight [mean±standard deviation] 1,099±266 g; 77 early umbilical cord clamping 1,058±289 g), delayed umbilical cord clamping was associated with less delivery room resuscitation, higher Apgar scores at 1 minute, and higher hematocrit. Delayed umbilical cord clamping was not associated with significant differences in the overall transfusion rate, peak bilirubin, any of the principle Vermont Oxford Network outcomes, or mortality. In LBW neonates (172 delayed umbilical cord clamping, birth weight [mean±standard deviation] 2,159±384 g; 172 early umbilical cord clamping 2,203±447 g), delayed umbilical cord clamping was associated with higher hematocrit and was not associated with a change in delivery room resuscitation or Apgar scores or with changes in the transfusion rate or peak bilirubin. Regression analysis showed increasing gestational age and birth weight and delayed umbilical cord clamping were the best predictors of higher hematocrit and less delivery room resuscitation. Delayed umbilical cord clamping can safely be performed in singleton premature neonates and is associated with a higher hematocrit, less delivery room

  6. Loading dynamics of a sliding DNA clamp.

    KAUST Repository

    Cho, Won-Ki

    2014-05-22

    Sliding DNA clamps are loaded at a ss/dsDNA junction by a clamp loader that depends on ATP binding for clamp opening. Sequential ATP hydrolysis results in closure of the clamp so that it completely encircles and diffuses on dsDNA. We followed events during loading of an E. coli β clamp in real time by using single-molecule FRET (smFRET). Three successive FRET states were retained for 0.3 s, 0.7 s, and 9 min: Hydrolysis of the first ATP molecule by the γ clamp loader resulted in closure of the clamp in 0.3 s, and after 0.7 s in the closed conformation, the clamp was released to diffuse on the dsDNA for at least 9 min. An additional single-molecule polarization study revealed that the interfacial domain of the clamp rotated in plane by approximately 8° during clamp closure. The single-molecule polarization and FRET studies thus revealed the real-time dynamics of the ATP-hydrolysis-dependent 3D conformational change of the β clamp during loading at a ss/dsDNA junction.

  7. Vibrations of post-buckled rods: The singular inextensible limit

    KAUST Repository

    Neukirch, Sébastien

    2012-01-01

    The small-amplitude in-plane vibrations of an elastic rod clamped at both extremities are studied. The rod is modeled as an extensible, shearable, planar Kirchhoff elastic rod under large displacements and rotations, and the vibration frequencies are computed both analytically and numerically as a function of the loading. Of particular interest is the variation of mode frequencies as the load is increased through the buckling threshold. While for some modes there are no qualitative changes in the mode frequencies, other frequencies experience rapid variations after the buckling threshold, the thinner the rod, the more abrupt the variations. Eventually, a mismatch for half of the frequencies at buckling arises between the zero thickness limit of the extensible model and the inextensible model. © 2011 Elsevier Ltd. All rights reserved.

  8. The RFC clamp loader: structure and function.

    Science.gov (United States)

    Yao, Nina Y; O'Donnell, Mike

    2012-01-01

    The eukaryotic RFC clamp loader couples the energy of ATP hydrolysis to open and close the circular PCNA sliding clamp onto primed sites for use by DNA polymerases and repair factors. Structural studies reveal clamp loaders to be heteropentamers. Each subunit contains a region of homology to AAA+ proteins that defines two domains. The AAA+ domains form a right-handed spiral upon binding ATP. This spiral arrangement generates a DNA binding site within the center of RFC. DNA enters the central chamber through a gap between the AAA+ domains of two subunits. Specificity for a primed template junction is achieved by a third domain that blocks DNA, forcing it to bend sharply. Thus only DNA with a flexible joint can bind the central chamber. DNA entry also requires a slot in the PCNA clamp, which is opened upon binding the AAA+ domains of the clamp loader. ATP hydrolysis enables clamp closing and ejection of RFC, completing the clamp loading reaction.

  9. Dynamic Study of a Capacitive MEMS Switch with Double Clamped-Clamped Microbeams

    Directory of Open Access Journals (Sweden)

    Hatem Samaali

    2014-01-01

    Full Text Available We study a capacitive MEMS switch composed of two clamped-clamped exible microbeams. We first develop a mathematical model for the MEMS switch where the upper microbeam represents the ground transmission line and the lower one represents the central transmission line. An electrostatic force is applied between the two microbeams to yield the switch to its ON and OFF states. We derive the equations of motion of the system and associated boundary conditions and solve the static and dynamic problems using the differential quadratic method. We show that using only nine grid points gives relatively accurate results when compared to those obtained using FEM. We also examine the transient behavior of the microswitch and obtain results indicating that subsequent reduction in actuation voltage, switching time, and power consumption are expected along with relatively good RF performances. ANSYS HFSS simulator is used in this paper to extract the RF characteristics of the microswitch. HFSS simulation results show that the insertion loss is as low as −0.31 dB and that the return loss is better than −12.41 dB at 10 GHz in the ON state. At the OFF state, the isolation is lower than −23 dB in the range of 10 to 50 GHz.

  10. How Does Patch Clamp Work?--An easy approach to understanding patch clamp mechanism

    Institute of Scientific and Technical Information of China (English)

    关兵才; 李之望

    2003-01-01

    In order to help patch clamp users,most of whom are not good enough at electrics and electronics,to understandthe complicated principles of patch clamp technique,we present a readily accessible explanation of patch clamp mechanism,in-cluding basic analysis of membrane currents under voltage clamp,achievement of voltage clamp and current recording,capaci-tance compensation,series resistance compensation,voltage offset correction,leak subtraction and current clamp,based on ourworking and teaching experience and with the aid of some useful formulae.

  11. Spent nuclear fuel rods encapsulated in copper

    Energy Technology Data Exchange (ETDEWEB)

    Hanes, H.D.

    1984-04-01

    Using hot isostatic pressing, spent nuclear fuel rods and other radioactive wastes can be encapsulated in solid copper. The copper capsule which is formed is free of pores and cracks, and is highly resistant to attack by reducing ground waters. Such capsules should contain radioactive materials safely for hundreds of thousands of years in underground storage.

  12. Electrostatic clamp manufactured by novel method

    NARCIS (Netherlands)

    Sligte, E. te; Storm, A.; Koster, N.B.

    2011-01-01

    Electrostatic clamps (ESCs), used in reticle and wafer handling, are presently manufactured using glass bonding and polishing technologies. We present a patented alternative concept to this process, relying on coating and etching processes rather than bonding. We manufactured a first prototype clamp

  13. 21 CFR 870.4450 - Vascular clamp.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vascular clamp. 870.4450 Section 870.4450 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Surgical Devices § 870.4450 Vascular clamp. (a) Identification. A vascular...

  14. Time to implement delayed cord clamping.

    Science.gov (United States)

    McAdams, Ryan M

    2014-03-01

    Immediate umbilical cord clamping after delivery is routine in the United States despite little evidence to support this practice. Numerous trials in both term and preterm neonates have demonstrated the safety and benefit of delayed cord clamping. In premature neonates, delayed cord clamping has been shown to stabilize transitional circulation, lessening needs for inotropic medications and reducing blood transfusions, necrotizing enterocolitis, and intraventricular hemorrhage. In term neonates, delayed cord clamping has been associated with decreased iron-deficient anemia and increased iron stores with potential valuable effects that extend beyond the newborn period, including improvements in long-term neurodevelopment. The failure to more broadly implement delayed cord clamping in neonates ignores published benefits of increased placental blood transfusion at birth and may represent an unnecessary harm for vulnerable neonates.

  15. Combat ready clamp medic technique.

    Science.gov (United States)

    Tovmassian, Robert V; Kragh, John F; Dubick, Michael A; Baer, David G; Blackbourne, Lorne H

    2012-01-01

    Junctional hemorrhage control device use on the battlefield might be lifesaving, but little experience is reported. The purpose of the present case report is to detail prehospital use of the Combat Ready Clamp (called the CRoC by its users, Combat Medical Systems, Fayetteville, NC; Instructions for Use, 2010) in casualty care in order to increase awareness of junctional hemorrhage control. The CRoC was used to control difficult inguinal bleeding on the battlefield for an Afghani man with a hindquarter traumatic amputation. The device promptly controlled exsanguination from a critical injury when placed during rotary-wing casualty evacuation. The flight medic applied the device in 90 seconds. The device performed well without complications to control bleeding. The CRoC, a new junctional hemorrhage control device, was used as indicated on the battlefield with mechanical and physiologic success and without device problems. By controlling difficult inguinal bleeding resulting from battlefield trauma, the device facilitated casualty stabilization and delivery to a surgical facility. The device facilitated the ability of a new flight medic to focus his expertise on a critically injured battlefield casualty with demonstrable success. 2012.

  16. POST-BUCKLING OF A CANTILEVER ROD WITH VARIABLE CROSS-SECTIONS UNDER COMBINED LOAD

    Institute of Scientific and Technical Information of China (English)

    吴莹; 李世荣; 滕兆春

    2003-01-01

    Based on the geometrically nonlinear theory of axially extensible elastic rods,the governing equations of post-buckling of a clamped-free rod with variable cross-sections,subjected to a combined load, a concentrated axial load P at the free end and a nonuniformly distributed axial load q, are established. By using shooting method, the strong nonlinear boundary value problems are numerically solved. The secondary equilibrium paths and the post-buckling configurations of the rod with linearly varied cross-sections are presented.

  17. Dynamic clamp with StdpC software.

    Science.gov (United States)

    Kemenes, Ildikó; Marra, Vincenzo; Crossley, Michael; Samu, Dávid; Staras, Kevin; Kemenes, György; Nowotny, Thomas

    2011-03-01

    Dynamic clamp is a powerful method that allows the introduction of artificial electrical components into target cells to simulate ionic conductances and synaptic inputs. This method is based on a fast cycle of measuring the membrane potential of a cell, calculating the current of a desired simulated component using an appropriate model and injecting this current into the cell. Here we present a dynamic clamp protocol using free, fully integrated, open-source software (StdpC, for spike timing-dependent plasticity clamp). Use of this protocol does not require specialist hardware, costly commercial software, experience in real-time operating systems or a strong programming background. The software enables the configuration and operation of a wide range of complex and fully automated dynamic clamp experiments through an intuitive and powerful interface with a minimal initial lead time of a few hours. After initial configuration, experimental results can be generated within minutes of establishing cell recording.

  18. Molecular Mechanisms of DNA Polymerase Clamp Loaders

    Science.gov (United States)

    Kelch, Brian; Makino, Debora; Simonetta, Kyle; O'Donnell, Mike; Kuriyan, John

    Clamp loaders are ATP-driven multiprotein machines that couple ATP hydrolysis to the opening and closing of a circular protein ring around DNA. This ring-shaped clamp slides along DNA, and interacts with numerous proteins involved in DNA replication, DNA repair and cell cycle control. Recently determined structures of clamp loader complexes from prokaryotic and eukaryotic DNA polymerases have revealed exciting new details of how these complex AAA+ machines perform this essential clamp loading function. This review serves as background to John Kuriyan's lecture at the 2010 Erice School, and is not meant as a comprehensive review of the contributions of the many scientists who have advanced this field. These lecture notes are derived from recent reviews and research papers from our groups.

  19. Clamp force and alignment checking device

    Energy Technology Data Exchange (ETDEWEB)

    Spicer, John Patrick; Cai, Wayne W.; Chakraborty, Debejyo; Mink, Keith

    2017-04-11

    A check fixture measures a total clamp force applied by a welder device. The welder device includes a welding horn having a plurality of weld pads and welding anvil having a plurality of weld pads. The check fixture includes a base member operatively supporting a plurality of force sensors. The base member and the force sensors are received between the weld pads of the welding horn and the anvil pads of the welding anvil. Each force sensor is configured to measure an individual clamp force applied thereto by corresponding weld and anvil pads when the base member is received between the welding horn and the welding anvil and the welder device is in the clamped position. The individual clamp forces are used to determine whether the weld and/or anvil pads are worn or misaligned.

  20. Ergonomic redesign and evaluation of a clamping tool handle.

    Science.gov (United States)

    Jung, Myung-Chul; Hallbeck, M Susan

    2005-09-01

    The handle of a commercial bar clamp was redesigned using ergonomic principles and then compared with an original clamp. Ten male and ten female students participated in simulated clamping tasks under various conditions, including different clamping heights, clamping methods, and handle-gripping methods, with respect to the dependent variables of clamping and handle-squeezing forces. The results showed that the redesigned clamp produced larger clamping force with lower handle-squeezing forces than the original clamp. As expected, males exerted more force than females in both clamping and squeezing forces. A pistol grip method was superior to an upside-down handle-gripping method. Two-handed operation was recommended for this type of clamp by simultaneously pulling the trigger and sliding the bar in order to initially tighten around objects. This study shows that the application of ergonomic guidelines increases the efficiency and usability of manual handtools.

  1. Clamped seismic metamaterials: ultra-low frequency stop bands

    Science.gov (United States)

    Achaoui, Y.; Antonakakis, T.; Brûlé, S.; Craster, R. V.; Enoch, S.; Guenneau, S.

    2017-06-01

    The regularity of earthquakes, their destructive power, and the nuisance of ground vibration in urban environments, all motivate designs of defence structures to lessen the impact of seismic and ground vibration waves on buildings. Low frequency waves, in the range 1-10 Hz for earthquakes and up to a few tens of Hz for vibrations generated by human activities, cause a large amount of damage, or inconvenience; depending on the geological conditions they can travel considerable distances and may match the resonant fundamental frequency of buildings. The ultimate aim of any seismic metamaterial, or any other seismic shield, is to protect over this entire range of frequencies; the long wavelengths involved, and low frequency, have meant this has been unachievable to date. Notably this is scalable and the effects also hold for smaller devices in ultrasonics. There are three approaches to obtaining shielding effects: bragg scattering, locally resonant sub-wavelength inclusions and zero-frequency stop-band media. The former two have been explored, but the latter has not and is examined here. Elastic flexural waves, applicable in the mechanical vibrations of thin elastic plates, can be designed to have a broad zero-frequency stop-band using a periodic array of very small clamped circles. Inspired by this experimental and theoretical observation, all be it in a situation far removed from seismic waves, we demonstrate that it is possible to achieve elastic surface (Rayleigh) wave reflectors at very large wavelengths in structured soils modelled as a fully elastic layer periodically clamped to bedrock. We identify zero frequency stop-bands that only exist in the limit of columns of concrete clamped at their base to the bedrock. In a realistic configuration of a sedimentary basin 15 m deep we observe a zero frequency stop-band covering a broad frequency range of 0-30 Hz.

  2. Piezoresistive cantilever force-clamp system

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sung-Jin; Petzold, Bryan C.; Pruitt, Beth L. [Department of Mechanical Engineering, Stanford University, Stanford, California 94305 (United States); Goodman, Miriam B. [Department of Molecular and Cellular Physiology, Stanford University, Stanford, California 94305 (United States)

    2011-04-15

    We present a microelectromechanical device-based tool, namely, a force-clamp system that sets or ''clamps'' the scaled force and can apply designed loading profiles (e.g., constant, sinusoidal) of a desired magnitude. The system implements a piezoresistive cantilever as a force sensor and the built-in capacitive sensor of a piezoelectric actuator as a displacement sensor, such that sample indentation depth can be directly calculated from the force and displacement signals. A programmable real-time controller operating at 100 kHz feedback calculates the driving voltage of the actuator. The system has two distinct modes: a force-clamp mode that controls the force applied to a sample and a displacement-clamp mode that controls the moving distance of the actuator. We demonstrate that the system has a large dynamic range (sub-nN up to tens of {mu}N force and nm up to tens of {mu}m displacement) in both air and water, and excellent dynamic response (fast response time, <2 ms and large bandwidth, 1 Hz up to 1 kHz). In addition, the system has been specifically designed to be integrated with other instruments such as a microscope with patch-clamp electronics. We demonstrate the capabilities of the system by using it to calibrate the stiffness and sensitivity of an electrostatic actuator and to measure the mechanics of a living, freely moving Caenorhabditis elegans nematode.

  3. Arterial clamping leads to stenosis at clamp sites after femoropopliteal bypass surgery

    NARCIS (Netherlands)

    Vriens, Bianca H. R.; Pol, Robert A.; Hulsebos, Robin G.; van Det, Rob J.; van der Palen, Job; Zeebregts, Clark J.; Geelkerken, Robert H.

    2015-01-01

    BACKGROUND: To date, the incidence and clinical relevance of arterial stenosis at clamp sites after femoropopliteal bypass surgery is unknown. METHODS: Ninety-four patients underwent a femoropopliteal bypass in which the arterial inflow and outflow clamp sites were controlled by the Fogarty-Soft-Inl

  4. Arterial clamping leads to stenosis at clamp sites after femoropopliteal bypass surgery

    NARCIS (Netherlands)

    Vriens, Bianca H.R.; Pol, Robert A.; Hulsebos, Robin G.; Det, van Rob J.; Palen, van der Job; Zeebregts, Clark J.; Geelkerken, Robert H.

    2015-01-01

    Background To date, the incidence and clinical relevance of arterial stenosis at clamp sites after femoropopliteal bypass surgery is unknown. Methods Ninety-four patients underwent a femoropopliteal bypass in which the arterial inflow and outflow clamp sites were controlled by the Fogarty-Soft-Inla

  5. Morphoelastic rods. Part I: A single growing elastic rod

    KAUST Repository

    Moulton, D.E.

    2013-02-01

    A theory for the dynamics and statics of growing elastic rods is presented. First, a single growing rod is considered and the formalism of three-dimensional multiplicative decomposition of morphoelasticity is used to describe the bulk growth of Kirchhoff elastic rods. Possible constitutive laws for growth are discussed and analysed. Second, a rod constrained or glued to a rigid substrate is considered, with the mismatch between the attachment site and the growing rod inducing stress. This stress can eventually lead to instability, bifurcation, and buckling. © 2012 Elsevier Ltd. All rights reserved.

  6. Vascular clamping in liver surgery: physiology, indications and techniques

    Directory of Open Access Journals (Sweden)

    Cherqui Daniel

    2010-03-01

    Full Text Available Abstract This article reviews the historical evolution of hepatic vascular clamping and their indications. The anatomic basis for partial and complete vascular clamping will be discussed, as will the rationales of continuous and intermittent vascular clamping. Specific techniques discussed and described include inflow clamping (Pringle maneuver, extra-hepatic selective clamping and intraglissonian clamping and outflow clamping (total vascular exclusion, hepatic vascular exclusion with preservation of caval flow. The fundamental role of a low Central Venous Pressure during open and laparoscopic hepatectomy is described, as is the difference in their intra-operative measurements. The biological basis for ischemic preconditioning will be elucidated. Although the potential dangers of vascular clamping and the development of modern coagulation devices question the need for systemic clamping; the pre-operative factors and unforseen intra-operative events that mandate the use of hepatic vascular clamping will be highlighted.

  7. Learning with Rods: One Account.

    Science.gov (United States)

    Cherry, Donald Esha

    This paper discusses one English as a Second Language (ESL) teacher's attempts to use cuisenaire rods as a language learning tool. Cuisenaire rods (sometimes called algebricks) vary in size from 1 x 1 x 10 centimeter sticks to 1 x 1 x 1 centimeter cubes, with each of the 10 sizes a different color. Although such rods have been used to teach…

  8. Design and test of clamping finger-chain type device for recycling agricultural plastic film%夹指链式残膜回收装置的设计及试验

    Institute of Scientific and Technical Information of China (English)

    段文献; 王吉奎; 李阳; 龚贺贺; 牛海龙; 罗威; 毕新胜

    2016-01-01

    The domestic equipment for recycling agricultural plastic film has the problems of low recovery rate of plastic film, wrapping the film collecting parts by plastics, or difficulty of separating the straw and soil from the film. In addition, film removing for the current methods is poor and high impurity content of recovered plastic film can’t be recycled. In order to solve these problems, the clamping finger-chain type device for recycling agricultural plastic film was designed. The designed device mainly consisted of film collecting device, film removing device, transmission system, side film shoveling, tie rod, transverse beam, residual film box, etc. The film collecting device mainly included film collecting frame, upper film collecting sprocket, under film collecting sprocket, film collecting chain, clamping finger, film cutting saw disk, supporting chain roller, tightening devices, etc. The film removing device mainly included film removing rotation shaft, film removing blade, driving sprocket, film removing bracket, bearing chock, etc. The film collecting device was driven by the ground wheel through the film collecting transmission system and the film removing device was driven by the tractor power output shaft through the film removing transmission. Through the design and mechanical analysis of the clamping finger-chain, the structure size parameters of it were determined, which contained the spacing between two clamping finger-chains was 220 mm, and its working angle was 40°, the effective length of clamping fingerL was 135 mm, and the angle between clamping finger and outer link was 20°. The tension mechanism could make the clamping finger-chain be always in a state of tension in the process of operation. The specification parameters of the selected spring were determined by analysis of the tensioning mechanism. Through the structure size design and motion analysis of film removing device, the film removing blade size was determined, and the length

  9. Compact, Stiff, Remotely-Actuable Quick-Release Clamp

    Science.gov (United States)

    Tsai, Ted W. (Inventor)

    2000-01-01

    The present invention provides a clamp that is compact and lightweight, yet provides high holding strength and stiffness or rigidity. The clamp uses a unique double slant interface design which provides mechanical advantages to resist forces applied to the clamp member as the load increases. The clamp allows for rapid and remote-activated release of the clamp jaws by applying only a small operating force to an over-center lock/release mechanism, such as by pulling a manual tether.

  10. IMPORTANT: Fluke is recalling Digital Clamp Meters

    CERN Multimedia

    2013-01-01

    Fluke is voluntarily recalling four models of Digital Clamp Meters: Fluke 373, 374, 375 and 376. If you own one of these clamp meters, please stop using it and send it back to Fluke for repair even if you have not experienced problems.   Description of the problem: "The printed circuit assembly may not be properly fastened to the test lead input jack. This may result in inaccurate voltage readings, including a low or no-voltage reading on a circuit energised with a hazardous voltage, presenting a shock, electrocution or thermal burn hazard." To determine if your clamp meter is affected by this recall notice, and for more information, click here.

  11. Design and application of multifunctional stomach clamp

    Institute of Scientific and Technical Information of China (English)

    Yun Fu Lu; Pi Wu Li; Xir Xin Zhang

    2000-01-01

    AIM Pylorus and pyloric vagus preserving gastrectomy (PPVPG) is an efficient operation mode for treatinggastric and duodenal ulcers. For its better application and popularization, we have designed andmanufactured a special multifunctional stomach clamp.METHODS The clamp has been designed carefully in view of the different sizes of the patients' stomachsand the different starting points of Latarjer nerves so as to facilitate the execution of the present operationmode, which requires the preservation of the vagus innervated pyloric region so as to make the remnantstomach maintain its normal physiological function and the vagus branches clinging antral seromuscular flapkept in proper size so that avoiding too much remaining antral mucosa is removed to cause greater difficultyin operation. With this in view, we observed and measured the distance between the Latarjer nerves distribution and the pyloric rings of 42 patients' stomachs in the course of operations. We bent an aluminumstring 3 mm thick for each stomach according to the size of antral seromuecular flap and chose an optimalcurvature from the 42 sizes for manufacturing the clamp. The clamp is made of 3 Cr13 stainless steel,consisting of three parts, the curved head, the fastening ring and the handle. The curved head is shapedalmost exactly like the remained antral seromuscular flap. The ring at its tip when in place fastens the twosides of the clamp so that the tissue of the stomach between will be clutched by an even force. On one sideare three cuts for moving the ring upwards, each cut representing 1 mm for fastening and adjustments can bemade in view of the thickness or thinness of the tissue. The handles bend backward for fighting shy of thecuts so as to facilitate the operation.RESULTS With the stomach disassociated in the light of PPVPG procedures, the clamp may easily beapplied from the upper part of the Latarjer nerves. The following merits can be noted. ① The curving line ofthe flap can be precisely

  12. Safety rod latch inspection

    Energy Technology Data Exchange (ETDEWEB)

    Leader, D.R.

    1992-02-01

    During an attempt to raise control rods from the 100 K reactor in December, one rod could not be withdrawn. Subsequent investigation revealed that a small button'' in the latch mechanism had broken off of the lock plunger'' and was wedged in a position that prevented rod withdrawal. Concern that this failure may have resulted from corrosion or some other metallurgical problem resulted in a request that SRL examine six typical latch mechanisms from the 100 L reactor by use of radiography and metallography. During the examination of the L-Area latches, a failed latch mechanism from the 100 K reactor was added to the investigation. Fourteen latches that had a history of problems were removed from K-Area and sent to SRL for inclusion in this study the week after the original seven assemblies were examined, bringing the total of latch assemblies discussed in this report to twenty one. Results of the examination of the K-Area latch that initiated this study is not included in this report.

  13. Safety rod latch inspection

    Energy Technology Data Exchange (ETDEWEB)

    Leader, D.R.

    1992-02-01

    During an attempt to raise control rods from the 100 K reactor in December, one rod could not be withdrawn. Subsequent investigation revealed that a small ``button`` in the latch mechanism had broken off of the ``lock plunger`` and was wedged in a position that prevented rod withdrawal. Concern that this failure may have resulted from corrosion or some other metallurgical problem resulted in a request that SRL examine six typical latch mechanisms from the 100 L reactor by use of radiography and metallography. During the examination of the L-Area latches, a failed latch mechanism from the 100 K reactor was added to the investigation. Fourteen latches that had a history of problems were removed from K-Area and sent to SRL for inclusion in this study the week after the original seven assemblies were examined, bringing the total of latch assemblies discussed in this report to twenty one. Results of the examination of the K-Area latch that initiated this study is not included in this report.

  14. Rapid kinetics of endocytosis at rod photoreceptor synapses depends upon endocytic load and calcium.

    Science.gov (United States)

    Cork, Karlene M; Thoreson, Wallace B

    2014-05-01

    Release from rods is triggered by the opening of L-type Ca2+ channels that lie beneath synaptic ribbons. After exocytosis, vesicles are retrieved by compensatory endocytosis. Previous work showed that endocytosis is dynamin-dependent in rods but dynamin-independent in cones. We hypothesized that fast endocytosis in rods may also differ from cones in its dependence upon the amount of Ca2+ influx and/or endocytic load. We measured exocytosis and endocytosis from membrane capacitance (C m) changes evoked by depolarizing steps in voltage clamped rods from tiger salamander retinal slices. Similar to cones, the time constant for endocytosis in rods was quite fast, averaging endocytosis kinetics in rods slowed after increasing Ca2+ channel activation with longer step durations or more strongly depolarized voltage steps. Endocytosis kinetics also slowed as Ca2+ buffering was decreased by replacing BAPTA (10 or 1 mM) with the slower Ca2+ buffer EGTA (5 or 0.5 mM) in the pipette solution. These data provide further evidence that endocytosis mechanisms differ in rods and cones and suggest that endocytosis in rods is regulated by both endocytic load and local Ca2+ levels.

  15. Prolonged penile strangulation with metal clamps

    Institute of Scientific and Technical Information of China (English)

    Chirag Patel; Richard Kim; Michael Delterzo; Run Wang

    2006-01-01

    Various different objects have been reported to strangulate the penis. We reported on a patient who used metal radiator clamps for an extended period of time. Workup included history, physical examination and urinalysis. The patient was taken to the operating room for further evaluation with cystourethroscopy and orthopedic wire cutters were used to break the metal bands.

  16. Cerebral haemodynamics during carotid cross-clamping.

    Science.gov (United States)

    Pistolese, G R; Ippoliti, A; Appolloni, A; Ronchey, S; Faraglia, V

    1993-03-01

    Carotid artery cross-clamping ischaemia during carotid endarterectomy (CEA) causes 5-30% of perioperative neurological deficits. This study was performed to identify possible clinical situations at higher risk for carotid cross-clamping ischaemia. 606 consecutive patients underwent CEA and were retrospectively studied; they were grouped according to risk factors, presence of associated vascular diseases, clinical pattern, angiographic and CT scan findings. Stump pressure measurement was provided in all patients, perioperative monitoring during CEA was performed by electroencephalogram (EEG) in 469 (77%) and somatosensorial evoked potentials (SEP) in 137 (23%). Local anaesthesia was used in 88 (14.5%) patients. Ischaemic changes during carotid cross-clamping were registered in 118 patients (19.5%). The incidence of cross-clamping ischaemia was then related to different factors; it affected 5.6% of asymptomatics, 25.4% of patients with fixed stroke and 38.5% of those with stenosis and contralateral occlusion. Angiographic and clinical correlation showed that patients with more severe lesions are mostly affected by clamping ischaemia (up to 55% in those with stroke and stenosis with contralateral occlusion). Age, hypertension and diabetes do not significantly affect incidence of ischaemic changes. Positive CT scan increased this risk; statistical relevance was found in regard to patients with unilateral or bilateral stenosis and in those with transient ischaemic attacks. A higher risk can be expected for subjects with more severe clinical and instrumental findings, even if no patients can be considered completely at risk or risk free. Perioperative monitoring is always mandatory and is of great importance in detecting ischaemic changes and preventing cerebral damage using a temporary intraluminal shunt.

  17. Dynamics and Stability of Pinned-Clamped and Clamped-Pinned Cylindrical Shells Conveying Fluid

    Science.gov (United States)

    Misra, A. K.; Wong, S. S. T.; Païdoussis, M. P.

    2001-11-01

    The paper examines the dynamics and stability of fluid-conveying cylindrical shells having pinned-clamped or clamped-pinned boundary conditions, where ``pinned'' is an abbreviation for ``simply supported''. Flügge's equations are used to describe the shell motion, while the fluid-dynamic perturbation pressure is obtained utilizing the linearized potential flow theory. The solution is obtained using two methods - the travelling wave method and the Fourier-transform approach. The results obtained by both methods suggest that the negative damping of the clamped-pinned systems and positive damping of the pinned-clamped systems, observed by previous investigators for any arbitrarily small flow velocity, are simply numerical artefacts; this is reinforced by energy considerations, in which the work done by the fluid on the shell is shown to be zero. Hence, it is concluded that both systems are conservative.

  18. Cone rod dystrophies

    Directory of Open Access Journals (Sweden)

    Hamel Christian P

    2007-02-01

    Full Text Available Abstract Cone rod dystrophies (CRDs (prevalence 1/40,000 are inherited retinal dystrophies that belong to the group of pigmentary retinopathies. CRDs are characterized by retinal pigment deposits visible on fundus examination, predominantly localized to the macular region. In contrast to typical retinitis pigmentosa (RP, also called the rod cone dystrophies (RCDs resulting from the primary loss in rod photoreceptors and later followed by the secondary loss in cone photoreceptors, CRDs reflect the opposite sequence of events. CRD is characterized by primary cone involvement, or, sometimes, by concomitant loss of both cones and rods that explains the predominant symptoms of CRDs: decreased visual acuity, color vision defects, photoaversion and decreased sensitivity in the central visual field, later followed by progressive loss in peripheral vision and night blindness. The clinical course of CRDs is generally more severe and rapid than that of RCDs, leading to earlier legal blindness and disability. At end stage, however, CRDs do not differ from RCDs. CRDs are most frequently non syndromic, but they may also be part of several syndromes, such as Bardet Biedl syndrome and Spinocerebellar Ataxia Type 7 (SCA7. Non syndromic CRDs are genetically heterogeneous (ten cloned genes and three loci have been identified so far. The four major causative genes involved in the pathogenesis of CRDs are ABCA4 (which causes Stargardt disease and also 30 to 60% of autosomal recessive CRDs, CRX and GUCY2D (which are responsible for many reported cases of autosomal dominant CRDs, and RPGR (which causes about 2/3 of X-linked RP and also an undetermined percentage of X-linked CRDs. It is likely that highly deleterious mutations in genes that otherwise cause RP or macular dystrophy may also lead to CRDs. The diagnosis of CRDs is based on clinical history, fundus examination and electroretinogram. Molecular diagnosis can be made for some genes, genetic counseling is

  19. Imperfect space clamp permits electrotonic interactions between inhibitory and excitatory synaptic conductances, distorting voltage clamp recordings.

    Directory of Open Access Journals (Sweden)

    Alon Poleg-Polsky

    Full Text Available The voltage clamp technique is frequently used to examine the strength and composition of synaptic input to neurons. Even accounting for imperfect voltage control of the entire cell membrane ("space clamp", it is often assumed that currents measured at the soma are a proportional indicator of the postsynaptic conductance. Here, using NEURON simulation software to model somatic recordings from morphologically realistic neurons, we show that excitatory conductances recorded in voltage clamp mode are distorted significantly by neighboring inhibitory conductances, even when the postsynaptic membrane potential starts at the reversal potential of the inhibitory conductance. Analogous effects are observed when inhibitory postsynaptic currents are recorded at the reversal potential of the excitatory conductance. Escape potentials in poorly clamped dendrites reduce the amplitude of excitatory or inhibitory postsynaptic currents recorded at the reversal potential of the other conductance. In addition, unclamped postsynaptic inhibitory conductances linearize the recorded current-voltage relationship of excitatory inputs comprising AMPAR and NMDAR-mediated components, leading to significant underestimation of the relative contribution by NMDARs, which are particularly sensitive to small perturbations in membrane potential. Voltage clamp accuracy varies substantially between neurons and dendritic arbors of different morphology; as expected, more reliable recordings are obtained from dendrites near the soma, but up to 80% of the synaptic signal on thin, distant dendrites may be lost when postsynaptic interactions are present. These limitations of the voltage clamp technique may explain how postsynaptic effects on synaptic transmission could, in some cases, be attributed incorrectly to presynaptic mechanisms.

  20. Active Brownian rods

    Science.gov (United States)

    Peruani, Fernando

    2016-11-01

    Bacteria, chemically-driven rods, and motility assays are examples of active (i.e. self-propelled) Brownian rods (ABR). The physics of ABR, despite their ubiquity in experimental systems, remains still poorly understood. Here, we review the large-scale properties of collections of ABR moving in a dissipative medium. We address the problem by presenting three different models, of decreasing complexity, which we refer to as model I, II, and III, respectively. Comparing model I, II, and III, we disentangle the role of activity and interactions. In particular, we learn that in two dimensions by ignoring steric or volume exclusion effects, large-scale nematic order seems to be possible, while steric interactions prevent the formation of orientational order at large scales. The macroscopic behavior of ABR results from the interplay between active stresses and local alignment. ABR exhibit, depending on where we locate ourselves in parameter space, a zoology of macroscopic patterns that ranges from polar and nematic bands to dynamic aggregates.

  1. Towards a Dynamic Clamp for Neurochemical Modalities

    Directory of Open Access Journals (Sweden)

    Catalina Maria Rivera

    2015-05-01

    Full Text Available The classic dynamic clamp technique uses a real-time electrical interface between living cells and neural simulations in order to investigate hypotheses about neural function and structure. One of the acknowledged drawbacks of that technique is the limited control of the cells’ chemical microenvironment. In this manuscript, we use a novel combination of nanosensor and microfluidic technology and microfluidic and neural simulations to add sensing and control of chemical concentrations to the dynamic clamp technique. Specifically, we use a microfluidic lab-on-a-chip to generate distinct chemical concentration gradients (ions or neuromodulators, to register the concentrations with embedded nanosensors and use the processed signals as an input to simulations of a neural cell. The ultimate goal of this project is to close the loop and provide sensor signals to the microfluidic lab-on-a-chip to mimic the interaction of the simulated cell with other cells in its chemical environment.

  2. Mechanical and metallurgical properties of carotid artery clamps.

    Science.gov (United States)

    Dujovny, M; Kossovsky, N; Kossowsky, R; Segal, R; Diaz, F G; Kaufman, H; Perlin, A; Cook, E E

    1985-11-01

    The mechanical and metallurgical properties of carotid artery clamps were evaluated. The pressure plate retreat propensity, metallurgical composition, surface morphology, magnetic properties, and corrosion resistance of the Crutchfield, Selverstone, Salibi, and Kindt clamps were tested. None of the clamps showed evidence of pressure plate retreat. The clamps differed significantly in their composition, surface cleanliness, magnetic properties, and corrosion resistance. The Crutchfield clamp was the only one manufactured from an ASTM-ANSI-approved implantable stainless steel (AISI 316) and the only clamp in which the surfaces were clean and free of debris. The Selverstone clamp was made principally from AISI 304 stainless steel, as was one Salibi clamp. The pressure plate on another Salibi clamp was made from a 1% chromium and 1% manganese steel. Machining and surface debris consisting principally of aluminum, silicon, and sulfur was abundant on the Selverstone and Salibi clamps. The Kindt clamp was manufactured from AISI 301 stainless steel with a silicate-aluminized outer coating. The Crutchfield and Selverstone clamps were essentially nonferromagnetic, whereas the Salibi and Kindt clamps were sensitive to magnetic flux. In the pitting potential corrosion test, the Crutchfield clamp demonstrated good corrosion resistance with a pitting potential of 310 mV and no surface corrosion or pitting by scanning electron microscopy examination. The Selverstone clamp had lower pitting potentials and showed various degrees of corrosion and surface pitting by scanning electron microscopy. The Salibi pressure plate had a very low pitting potential of -525 mV and showed severe corrosion. By metallurgical criteria, only the Crutchfield clamp is suitable for long term implantation.

  3. Γ-source Neutral Point Clamped Inverter

    DEFF Research Database (Denmark)

    Mo, Wei; Loh, Poh Chiang; Blaabjerg, Frede

    Transformer based Z-source inverters are recently proposed to achieve promising buck-boost capability. They have improved higher buck-boost capability, smaller size and less components count over Z-source inverters. On the other hand, neutral point clamped inverters have less switching stress...... and better output performance comparing with traditional two-level inverters. Integrating these two types of configurations can help neutral point inverters achieve enhanced votlage buck-boost capability....

  4. AN ACTIVE VALVE WITH A CLAMPED MEMBRANE

    DEFF Research Database (Denmark)

    2009-01-01

    An active valve for use e.g. in fluidic microsystems is provided, wherein the active valve comprises a membrane having at least one flow gate, arranged between a first and a second substantially rigid element. Adjusting means provides an adjustment of the clamping force on membrane arranged between...... the first and second substantially rigid element. Hereby the flow rate through the active valve can be continuously and precisely controlled....

  5. Control of Rod-Rod Interactions in Poly(3-alkylthiophenes)

    Science.gov (United States)

    Ho, Victor; Boudouris, Bryan W.; Segalman, Rachel A.

    2010-03-01

    Poly(3-hexylthiophene) is a commonly used semiconducting polymer because of its relatively high charge transport ability, low band gap, and solution processiblity. Strong intermolecular interactions lead to the formation of nanofibers during crystallization, which prevents long-range microstructural ordering. We show rod-rod interactions, parameterized by the Maier-Saupe parameter, can be controlled by rational polythiophene side chain design. Effects of side chain passivation are evidenced by a depressed melting temperature and the presence of a liquid crystalline region. Additionally, the Maier-Saupe parameters are estimated for poly(3-dodecylthiophene) and poly(3-ethylhexylthiophene); the relative magnitudes of each are related to the interchain spacings obtained by x-ray diffraction experiments. The systematic tuning of the rod-rod interactions in polythiophenes allows for manipulation of the ratio of Maier-Saupe to the Flory-Huggins parameter, a crucial value in obtaining long-range order in rod-coil block copolymer morphologies.

  6. Vibration of an eccentrically clamped annular plate

    Science.gov (United States)

    Tseng, J.-G.; Wickert, J. A.

    1994-04-01

    Small amplitude vibration of an eccentric annular plate, which is free along its outer edge and clamped along the interior, is investigated through experimental and analytical methods. A disk with this geometry, or a stacked array in which the clamping and symmetry axes of each disk are nominally coincident, is common in data storage and brake systems applications. In the present case, the geometric imperfections on the boundary can have important implications for the disk's dynamic response. Changes that occur in the natural frequency spectrum, the mode shapes, and the free response under eccentric mounting are studied through laboratory measurements and an approximate discrete model of the plate. The natural frequencies and modes are found through global discretization of the Kamke quotient for a classical thin plate. For the axisymmetric geometry, the natural frequencies of the sine and cosine vibration modes for a specified number of nodal diameters are repeated. With increasing eccentricity, on the other hand, each pair of repeated frequencies splits at a rate that depends on the number of nodal diameters. Over a range of clamping and eccentricity ratios, the model's predictions are compared to the measured results.

  7. Multilevel-clamped multilevel converters (MLC2)

    DEFF Research Database (Denmark)

    Rodriguez, Pedro; Bellar, Maria Dias; Muñoz-Aguliar, Raúl Santiago;

    2012-01-01

    This letter introduces a new series of multilevel (ML) converters based on the ML clamping concept. By applying this technique, a ML clamping unit (MCU) conveys additional levels for synthesizing the output waveforms of a diode-clampedML dc– ac power converter. The basic building block of the ML ...

  8. Analysis of the Pallet Clamping Conditions in Work Positioning

    Directory of Open Access Journals (Sweden)

    L. A. Kolesnikov

    2016-01-01

    Full Text Available Pallets of automatic transfer lines serve as the technological and work-transfer equipment. However, their design is based on the general principles of designing machine accessories. Calculation of the basic design parameters of work based on their functioning features is fairly relevant.In pallet transfer movement over work positioning there is a mismatch between axes of the basic bushing of a pallet and the clamping locks of positioning. The paper identifies the factors influencing it, and defines the conditions to ensure the trouble-free clamping lock. The circular and rhombic clamping of pallet is simultaneous. Further, a clamping load is calculated from the pallet mass (together with the work-piece and the geometric parameters of the pallet clamping.The paper reveals three movement stages of the clamping lock in a vertical plane when setting the pallet in work positioning:- a clamping lock free play till it encounters with the location bushing;- a clamping lock play length when the lead-in chamfer contacts the bushing chamfer;- a clamping lock play length over the circular surface of bushing.The study of this process has allowed us to calculate the time of pallet clamping and dynamic loads acting on the clamping lock. These calculations made it possible to calculate the required diameter of the clamping lock. The presented calculations allow a reasonable assigning the main design parameters of work positioning for the pallet automatic lines.

  9. Single molecule study of a processivity clamp sliding on DNA

    Energy Technology Data Exchange (ETDEWEB)

    Laurence, T A; Kwon, Y; Johnson, A; Hollars, C; O?Donnell, M; Camarero, J A; Barsky, D

    2007-07-05

    Using solution based single molecule spectroscopy, we study the motion of the polIII {beta}-subunit DNA sliding clamp ('{beta}-clamp') on DNA. Present in all cellular (and some viral) forms of life, DNA sliding clamps attach to polymerases and allow rapid, processive replication of DNA. In the absence of other proteins, the DNA sliding clamps are thought to 'freely slide' along the DNA; however, the abundance of positively charged residues along the inner surface may create favorable electrostatic contact with the highly negatively charged DNA. We have performed single-molecule measurements on a fluorescently labeled {beta}-clamp loaded onto freely diffusing plasmids annealed with fluorescently labeled primers of up to 90 bases. We find that the diffusion constant for 1D diffusion of the {beta}-clamp on DNA satisfies D {le} 10{sup -14} cm{sup 2}/s, much slower than the frictionless limit of D = 10{sup -10} cm{sup 2}/s. We find that the {beta} clamp remains at the 3-foot end in the presence of E. coli single-stranded binding protein (SSB), which would allow for a sliding clamp to wait for binding of the DNA polymerase. Replacement of SSB with Human RP-A eliminates this interaction; free movement of sliding clamp and poor binding of clamp loader to the junction allows sliding clamp to accumulate on DNA. This result implies that the clamp not only acts as a tether, but also a placeholder.

  10. 21 CFR 882.4460 - Neurosurgical head holder (skull clamp).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Neurosurgical head holder (skull clamp). 882.4460 Section 882.4460 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... holder (skull clamp). (a) Identification. A neurosurgical head holder (skull clamp) is a device used...

  11. Cuisenaire Rods Go to College.

    Science.gov (United States)

    Chinn, Phyllis; And Others

    1992-01-01

    Presents examples of questions and answers arising from a hands-on and exploratory approach to discrete mathematics using cuisenaire rods. Combinatorial questions about trains formed of cuisenaire rods provide the setting for discovering numerical patterns by experimentation and organizing the results using induction and successive differences.…

  12. Transverse vibration spectrum of a part of a moving rod under a longitudinal load

    Science.gov (United States)

    Akulenko, L. D.; Georgievskii, D. V.; Nesterov, S. V.

    2015-03-01

    We study the natural transverse vibrations of a constant-length part of a rectilinear thin rod moving along a neutral line in unstrained state. The displacement occurs between two fixed coaxial rod guides (clamps) and the distance between them is equal to the length of the vibration part of the rod. Moreover, it is assumed that a constant longitudinal force acts along the neutral line, and two significantly different cases are distinguished: the force extends the rod, and the force compresses the rod. The vibration process is described by a nonself-adjoint boundary value problem. For arbitrary values of the rod displacement velocity and longitudinal forces, the natural frequencies of possible vibration modes are determined and analyzed by a numerical-analytical procedure with a prescribed accuracy. The global properties of the spectrum depending on the velocity, the longitudinal force, and mode number are determined. For higher-order modes, the domains are discovered where the frequencies nonuniquely depend on the rod motion velocity and the value and direction of the longitudinal force and where the lower vibration frequencies can be absent as the rod motion velocity increases. It is shown that the picture of partial vibrations from the standpoint of an immovable observer cardinally differs from the commonly known picture for the immovable rod. The obtained results are interesting for studying vibrations of various elements of moving elastic media, including the case of systems with moving boundaries. These results can also have technical applications in problems of dynamics and strength of devices, machines, and mechanisms in textile industry in the filament and rope manufacturing and in metallurgy, in particular, in rolling of metallic rods and strips, in wire drawing, and in production of plastic articles and paper rolls. The developed technique for calculating the natural frequencies and shape modes can be used to analyze the transverse vibrations of parts of

  13. Timing of umbilical cord clamping of term infants.

    Science.gov (United States)

    Ceriani Cernadas, José María

    2017-04-01

    For at least over 200 years, multiple controversies have arisen around the timing of umbilical cord clamping. In the past decades, early cord clamping (within the first 15 seconds) had markedly prevailed. Only in the 21st century, randomized controlled trials have demonstrated the benefits of delayed cord clamping (at 2-3 minutes). Delayed cord clamping has been practiced in obstetrics based on the recommendations made by scientific societies and in systematic reviews, which have provided solid evidence to support this practice in term infants. This review describes the most relevant factors supporting the use of delayed cord clamping in term infants. It points out the essential role played by physiological mechanisms which, undoubtedly, allow us to understand the benefits of delayed cord clamping and advise us to wait for what nature has established. Other relevant aspects supporting delayed cord clamping are also described here. Sociedad Argentina de Pediatría.

  14. Eulerian formulation of elastic rods

    Science.gov (United States)

    Huynen, Alexandre; Detournay, Emmanuel; Denoël, Vincent

    2016-06-01

    In numerous biological, medical and engineering applications, elastic rods are constrained to deform inside or around tube-like surfaces. To solve efficiently this class of problems, the equations governing the deflection of elastic rods are reformulated within the Eulerian framework of this generic tubular constraint defined as a perfectly stiff normal ringed surface. This reformulation hinges on describing the rod-deformed configuration by means of its relative position with respect to a reference curve, defined as the axis or spine curve of the constraint, and on restating the rod local equilibrium in terms of the curvilinear coordinate parametrizing this curve. Associated with a segmentation strategy, which partitions the global problem into a sequence of rod segments either in continuous contact with the constraint or free of contact (except for their extremities), this re-parametrization not only trivializes the detection of new contacts but also transforms these free boundary problems into classic two-points boundary-value problems and suppresses the isoperimetric constraints resulting from the imposition of the rod position at the extremities of each rod segment.

  15. Status of rod consolidation, 1988

    Energy Technology Data Exchange (ETDEWEB)

    Bailey, W.J.

    1989-01-01

    It is estimated that the spent fuel storage pools at some domestic light-water reactors will run out of space before 2003, the year that the US Department of Energy currently predicts it will have a repository available. Of the methods being studied to alleviate the problem, rod consolidation is one of the leading candidates for achieving more efficient use of existing space in spent fuel storage pools. Rod consolidation involves mechanically removing all the fuel rods from the fuel assembly hardware (i.e., the structural components) and placing the fuel rods in a close-packed array in a canister without space grids. A typical goal of rod consolidation systems is to insert the fuel rods from two fuel assemblies into a canister that has the same exterior dimensions as one standard fuel assembly (i.e., to achieve a consolidation or compaction ratio of 2:1) and to compact the nonfuel-bearing structural components from those two fuel assemblies by a factor of 10 to 20. This report provides an overview of the current status of rod consolidation in the United States and a small amount of information on related activities in other countries. 85 refs., 36 figs., 5 tabs.

  16. Optimization of a clamped plate silencer.

    Science.gov (United States)

    Wang, Chunqi; Han, Jun; Huang, Lixi

    2007-02-01

    A previous theoretical study [L. Huang, J. Acoust. Soc. Am. 119, 2628-2638 (2006)] shows that, in a duct, a simply supported plate covering a side-branch rigid cavity can function effectively as a wave reflector over a broad range of low to medium frequencies. In this study, analytical formulation is extended to the boundary condition of clamped plate, which is easier to implement in practice. The theoretical model is tested experimentally using balsawood, which has a very high stiffness to mass ratio. The spectral peaks and shapes of the measured TL are in agreement with those calculated theoretically, attempts are also made to account for the considerable sound absorption in the rig. Further numerical studies based on the validated model show that, for a uniform plate, the optimal stopband is narrower and the lower band limit is worse than that of the simply supported configuration. However, a wave reflector using nonuniform, clamped plates with thinner ends out-performs the simply supported configuration in every aspect. Analyses show that the improvement is attributed to the increased acoustic radiation efficiency over the bulk length of the nonuniform plate, which behaves more like a rigid plate.

  17. Topological mixing with ghost rods

    Science.gov (United States)

    Gouillart, Emmanuelle; Thiffeault, Jean-Luc; Finn, Matthew D.

    2006-03-01

    Topological chaos relies on the periodic motion of obstacles in a two-dimensional flow in order to form nontrivial braids. This motion generates exponential stretching of material lines, and hence efficient mixing. Boyland, Aref, and Stremler [J. Fluid Mech. 403, 277 (2000)] have studied a specific periodic motion of rods that exhibits topological chaos in a viscous fluid. We show that it is possible to extend their work to cases where the motion of the stirring rods is topologically trivial by considering the dynamics of special periodic points that we call “ghost rods”, because they play a similar role to stirring rods. The ghost rods framework provides a new technique for quantifying chaos and gives insight into the mechanisms that produce chaos and mixing. Numerical simulations for Stokes flow support our results.

  18. Self-encapsulation, or the ‘dripping’ of an elastic rod

    Science.gov (United States)

    Bosi, F.; Misseroni, D.; Dal Corso, F.; Bigoni, D.

    2015-01-01

    A rod covering a fixed span is loaded at the middle with a transverse force, such that with increasing load a progressive deflection occurs. After a certain initial deflection, a phenomenon is observed where two points of the rod come in contact with each other. This is defined as the ‘dripping point’ and is when ‘self-encapsulation’ of the elastic rod occurs. Dripping seems at a first glance to be impossible and definitely cannot occur in the presence of ‘ordinary’ constraints (such as simple supports or clamps) at the ends of the span. However, the elastica governs oscillating pendulums, buckling rods and pendant drops, so that a possibility for self-encapsulation might be imagined. This phenomenon is indeed demonstrated (both theoretically and experimentally) to occur when at least one of the constraints at the ends of the rod is a sliding sleeve. This mechanical device generates a configurational force, causing the dripping of the rod, in a fully elastic set-up. PMID:26346447

  19. Harmonic Resonances in Metal Rods - Easy Experimentation with a Smartphone and Tablet PC

    Science.gov (United States)

    Hirth, Michael; Gröber, Sebastian; Kuhn, Jochen; Müller, Andreas

    2016-03-01

    A variety of experiments with smartphones and tablet PCs allow a precise analysis of acoustic phenomena. For example, we recently described an experiment in which a noise signal simultaneously triggered harmonic acoustic resonances in the air column of a tube open at both ends and a tube closed at one end. The measured resonant frequencies were used to determine the speed of sound in air with an error less than 4%. The present article describes experiments for harmonic resonances in another type of one-dimensional wave carrier, viz. clamped metal rods. Resonances are generated by hitting one end face of the rod; the resonant frequencies can then be measured by an app on a smartphone or tablet PC. The experiments can be used to explore how the excitement of particular resonant frequencies depend on boundary conditions like the length of the rod, the number and specific positions of fixed points of the rod, and the rod's material. In addition the rod's longitudinal (the so-called extensional) speed of sound can be determined.

  20. Obstetricians' attitudes and beliefs regarding umbilical cord clamping.

    Science.gov (United States)

    Jelin, Angie C; Kuppermann, Miriam; Erickson, Kristine; Clyman, Ronald; Schulkin, Jay

    2014-09-01

    Although delayed umbilical cord clamping has been demonstrated to reduce the incidence of intraventricular hemorrhage and neonatal sepsis, and decrease the need for neonatal transfusions (without affecting cord pH, Apgar scores or the need for phototherapy), the extent to which this practice is being employed is unknown. We conducted a survey of US obstetricians to assess their attitudes and beliefs about cord clamping. Questionnaires were randomly mailed to members of the American College of Obstetricians and Gynecologists (ACOG), and the Collaborative Ambulatory Research Network (CARN). The data were analyzed using Chi-square and Student t tests. The response rates for the CARN and other ACOG members were 47% and 21%, respectively. Most (88%) responders reported their hospital had no umbilical cord clamping policy. The most frequent response for optimal timing of umbilical cord clamping, regardless of gestational age, was "don't know". Potential for neonatal red blood cell transfusion was the only concern cited as a reason for being somewhat or very inclined to delay umbilical cord clamping (51%). Delayed neonatal resuscitation (76%) was listed as a reason to clamp the cord immediately, despite the paucity of literature to support immediate cord clamping in this cohort. Despite substantial evidence supporting the practice of delayed cord clamping, few institutions have policies regarding this practice. Moreover, obstetricians' beliefs about the appropriate timing for umbilical cord clamping are not consistent with the evidence that demonstrates its beneficial impact on neonatal outcomes.

  1. Delayed cord clamping and cord gas analysis at birth.

    Science.gov (United States)

    Xodo, Serena; Xodo, Luigi; Berghella, Vincenzo

    2017-09-16

    Delayed cord clamping for at least 60 seconds in both term and preterm babies is a major recent change in clinical care. Delayed cord clamping has several effects on other possible interventions. One of these is the effect of delayed cord clamping on umbilical artery gas analysis. When indicated, umbilical artery gas analysis can safely be done either with early cord clamping, or, probably most of the times it is necessary, during delayed cord clamping with the cord still unclamped. Paired blood samples (one from the umbilical artery and one from the umbilical vein) can be taken from the pulsating and unclamped cord, immediately after birth, during delayed cord clamping, without any effect on either the accuracy of umbilical artery gas analysis or on the transfusion of blood through delayed cord clamping. Umbilical artery gas analysis should instead not be done after delayed cord clamping, since delayed cord clamping alters several acid-based parameters and lactate values. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  2. Thermal stiffening of clamped elastic ribbons

    Science.gov (United States)

    Wan, Duanduan; Nelson, David R.; Bowick, Mark J.

    2017-07-01

    We use molecular dynamics to study the vibrations of a thermally fluctuating two-dimensional elastic membrane clamped at both ends. We directly extract the eigenmodes from resonant peaks in the frequency domain of the time-dependent height and measure the dependence of the corresponding eigenfrequencies on the microscopic bending rigidity of the membrane, taking care also of the subtle role of thermal contraction in generating a tension when the projected area is fixed. At finite temperatures we show that the effective (macroscopic) bending rigidity tends to a constant as the bare bending rigidity vanishes, consistent with theoretical arguments that the large-scale bending rigidity of the membrane arises from a strong thermal renormalization of the microscopic bending rigidity. Experimental realizations include covalently bonded two-dimensional atomically thin membranes such as graphene and molybdenum disulfide or soft matter systems such as the spectrin skeleton of red blood cells or diblock copolymers.

  3. The PCNA-RFC families of DNA clamps and clamp loaders.

    Science.gov (United States)

    Majka, Jerzy; Burgers, Peter M J

    2004-01-01

    The proliferating cell nuclear antigen PCNA functions at multiple levels in directing DNA metabolic pathways. Unbound to DNA, PCNA promotes localization of replication factors with a consensus PCNA-binding domain to replication factories. When bound to DNA, PCNA organizes various proteins involved in DNA replication, DNA repair, DNA modification, and chromatin modeling. Its modification by ubiquitin directs the cellular response to DNA damage. The ring-like PCNA homotrimer encircles double-stranded DNA and slides spontaneously across it. Loading of PCNA onto DNA at template-primer junctions is performed in an ATP-dependent process by replication factor C (RFC), a heteropentameric AAA+ protein complex consisting of the Rfc1, Rfc2, Rfc3, Rfc4, and Rfc5 subunits. Loading of yeast PCNA (POL30) is mechanistically distinct from analogous processes in E. coli (beta subunit by the gamma complex) and bacteriophage T4 (gp45 by gp44/62). Multiple stepwise ATP-binding events to RFC are required to load PCNA onto primed DNA. This stepwise mechanism should permit editing of this process at individual steps and allow for divergence of the default process into more specialized modes. Indeed, alternative RFC complexes consisting of the small RFC subunits together with an alternative Rfc1-like subunit have been identified. A complex required for the DNA damage checkpoint contains the Rad24 subunit, a complex required for sister chromatid cohesion contains the Ctf18 subunit, and a complex that aids in genome stability contains the Elg1 subunit. Only the RFC-Rad24 complex has a known associated clamp, a heterotrimeric complex consisting of Rad17, Mec3, and Ddc1. The other putative clamp loaders could either act on clamps yet to be identified or act on the two known clamps.

  4. The Third ATLAS ROD Workshop

    CERN Multimedia

    Poggioli, L.

    A new-style Workshop After two successful ATLAS ROD Workshops dedicated to the ROD hardware and held at the Geneva University in 1998 and in 2000, a new style Workshop took place at LAPP in Annecy on November 14-15, 2002. This time the Workshop was fully dedicated to the ROD-TDAQ integration and software in view of the near future integration activities of the final RODs for the detector assembly and commissioning. More precisely, the aim of this workshop was to get from the sub-detectors the parameters needed for T-DAQ, as well as status and plans from ROD builders. On the other hand, what was decided and assumed had to be stated (like EB decisions and URDs), and also support plans. The Workshop gathered about 70 participants from all ATLAS sub-detectors and the T-DAQ community. The quite dense agenda allowed nevertheless for many lively discussions, and for a dinner in the old town of Annecy. The Sessions The Workshop was organized in five main sessions: Assumptions and recommendations Sub-de...

  5. Analysis of Contact Characteristic of Overhead Line and Suspension Clamp

    Directory of Open Access Journals (Sweden)

    Zhao Xinze

    2013-01-01

    Full Text Available In this paper, a LGJ150/25 type ACSR transmission line and a CGU-3 type suspension clamp are taken as research objects. A contact model of the conductor and the clamp was established by using finite element method. The effects of sag angle of the conductor, holding force and tension force in section are analyzed. The results showed that the contact area in the middle of the clamp is of belt-like type. The extreme values of tress were observed on the edge of the contact area and near the edge of keeper. In clamp section, suspension angle had the greatest influence on contact stress, and then the clamp force. The tension force in section played a most important role in these affecting factors. In the exit section of clamp, the biggest impact factor was tension force in this section, then the suspension angle, the third was clamp force. The results provide theoretical basis on reducing corona loss, optimization the clamp. Doubtlessly, the conclusion has important theoretical significance and application value.

  6. Advanced patch-clamp techniques and single-channel analysis

    NARCIS (Netherlands)

    Biskup, B; Elzenga, JTM; Homann, U; Thiel, G; Wissing, F; Maathuis, FJM

    1999-01-01

    Much of our knowledge of ion-transport mechanisms in plant cell membranes comes from experiments using voltage-clamp. This technique allows the measurement of ionic currents across the membrane, whilst the voltage is held under experimental control. The patch-clamp technique was developed to study t

  7. Studying mechanosensitive ion channels with an automated patch clamp

    NARCIS (Netherlands)

    Barthmes, Maria; Jose, Mac Donald F; Birkner, Jan Peter; Brüggemann, Andrea; Wahl-Schott, Christian; Kocer, Armagan

    2014-01-01

    Patch clamp electrophysiology is the main technique to study mechanosensitive ion channels (MSCs), however, conventional patch clamping is laborious and success and output depends on the skills of the operator. Even though automated patch systems solve these problems for other ion channels, they cou

  8. Applications of alcohol clamping in early drug development

    NARCIS (Netherlands)

    Zoethout, Remco Wiebe Martijn

    2012-01-01

    This thesis describes the development of a novel alcohol clamp, a new method to obtain stable plasma levels of alcohol and its application in CNS-research. The method might have several advantages that were explored in subsequent studies described in this thesis. The stability of the alcohol clamp w

  9. OPTIMAL TIMING FOR CLAMPING THE UMBILICAL CORD AFTER BIRTH

    Science.gov (United States)

    Raju, Tonse N. K.; Singal, Nalini

    2013-01-01

    Synopsis This paper provides a brief overview of pros and cons of clamping the cord too early (within seconds) after birth. It also highlights evolving data that suggests that delaying cord clamping for 30–60 seconds after birth is beneficial to the baby and the mother, with no measurable negative effects. PMID:23164185

  10. 21 CFR 876.5160 - Urological clamp for males.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Urological clamp for males. 876.5160 Section 876.5160 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5160 Urological clamp for...

  11. Topological Optimization of Rod Mixers

    Science.gov (United States)

    Finn, Matthew D.; Thiffeault, Jean-Luc

    2006-11-01

    Stirring of fluid with moving rods is necessary in many practical applications to achieve homogeneity. These rods are topological obstacles that force stretching of fluid elements. The resulting stretching and folding is commonly observed as filaments and striations, and is a precursor to mixing. In a space-time diagram, the trajectories of the rods form a braid [1], and the properties of this braid impose a minimal complexity in the flow. We discuss how optimal mixing protocols can be obtained by a judicious choice of braid, and how these protocols can be implemented using simple gearing [2].[12pt] [1] P. L. Boyland, H. Aref, and M. A. Stremler, JFM 403, 277 (2000).[8pt] [2] J.-L. Thiffeault and M. D. Finn, http://arxiv.org/nlin/0603003

  12. Advanced gray rod control assembly

    Energy Technology Data Exchange (ETDEWEB)

    Drudy, Keith J; Carlson, William R; Conner, Michael E; Goldenfield, Mark; Hone, Michael J; Long, Jr., Carroll J; Parkinson, Jerod; Pomirleanu, Radu O

    2013-09-17

    An advanced gray rod control assembly (GRCA) for a nuclear reactor. The GRCA provides controlled insertion of gray rod assemblies into the reactor, thereby controlling the rate of power produced by the reactor and providing reactivity control at full power. Each gray rod assembly includes an elongated tubular member, a primary neutron-absorber disposed within the tubular member said neutron-absorber comprising an absorber material, preferably tungsten, having a 2200 m/s neutron absorption microscopic capture cross-section of from 10 to 30 barns. An internal support tube can be positioned between the primary absorber and the tubular member as a secondary absorber to enhance neutron absorption, absorber depletion, assembly weight, and assembly heat transfer characteristics.

  13. Characterizing the dynamics of a flexible rod wrapped by transverse repeated ribs subjected to axial flow

    Energy Technology Data Exchange (ETDEWEB)

    Perets, Y., E-mail: yaronprts@gmail.com [Department of Mechanical Engineering, Ben-Gurion University of the Negev, Beer-Sheva (Israel); Sher, E. [Faculty of Aerospace Engineering, Technion – Israel Institute of Technology, Haifa (Israel); Harari, R. [Nuclear Research Center – Negev (NRCN), Beer-Sheva (Israel)

    2014-04-01

    Highlights: • The dynamic instability of a repeated ribs cylindrical rod in annular axial flow geometry was studied. • The results indicate a strong dependency between rod instability and rib roughness. • The rod dynamics become stabilized when the pitch-to-height ratio of the ribs increases. • Increase of the rib width-to-height ratio destabilizes the rod. • The nonlinear model confirms the existence of post critical instability and the reliability of the linear results. - Abstract: This study focuses on the dynamics of a flexible cylindrical structure wrapped by repeated transverse rectangular ribs, in an annular flow geometry, under two boundary conditions: simply supported ends and clamped ends. The dynamics is predicted by linear and nonlinear theories. Based on the linear equation a straightforward nonlinear equation can be derived. A parametric investigation of the effect of the ribs’ dimensionless geometry characterized by the pitch-to-height and width-to-height ratios, on the fluid-elastic instability characteristics is considered. The results of the present study indicate a strong dependency between rod instability and rib roughness. The nonlinear model confirms the existence of post critical instability and the reliability of the linear results.

  14. Cell-Detection Technique for Automated Patch Clamping

    Science.gov (United States)

    McDowell, Mark; Gray, Elizabeth

    2008-01-01

    A unique and customizable machinevision and image-data-processing technique has been developed for use in automated identification of cells that are optimal for patch clamping. [Patch clamping (in which patch electrodes are pressed against cell membranes) is an electrophysiological technique widely applied for the study of ion channels, and of membrane proteins that regulate the flow of ions across the membranes. Patch clamping is used in many biological research fields such as neurobiology, pharmacology, and molecular biology.] While there exist several hardware techniques for automated patch clamping of cells, very few of those techniques incorporate machine vision for locating cells that are ideal subjects for patch clamping. In contrast, the present technique is embodied in a machine-vision algorithm that, in practical application, enables the user to identify good and bad cells for patch clamping in an image captured by a charge-coupled-device (CCD) camera attached to a microscope, within a processing time of one second. Hence, the present technique can save time, thereby increasing efficiency and reducing cost. The present technique involves the utilization of cell-feature metrics to accurately make decisions on the degree to which individual cells are "good" or "bad" candidates for patch clamping. These metrics include position coordinates (x,y) in the image plane, major-axis length, minor-axis length, area, elongation, roundness, smoothness, angle of orientation, and degree of inclusion in the field of view. The present technique does not require any special hardware beyond commercially available, off-the-shelf patch-clamping hardware: A standard patchclamping microscope system with an attached CCD camera, a personal computer with an imagedata- processing board, and some experience in utilizing imagedata- processing software are all that are needed. A cell image is first captured by the microscope CCD camera and image-data-processing board, then the image

  15. Trends in Aortic Clamp Use During Coronary Artery Bypass Surgery: The Effect of Aortic Clamping Strategies on Neurologic Outcomes

    Science.gov (United States)

    Daniel, William T.; Kilgo, Patrick; Puskas, John D.; Thourani, Vinod H.; Lattouf, Omar M.; Guyton, Robert A.; Halkos, Michael E.

    2013-01-01

    Objective The purpose of this study was to determine the impact of different clamping strategies during CABG on the incidence of postoperative stroke. Methods In this case-control study, all patients at Emory hospitals from 2002–2009 with postoperative stroke after isolated CABG (N=141) were matched 1:4 to a contemporaneous cohort of patients without postoperative stroke (N=565). Patients were matched according to the Society of Thoracic Surgeons (STS) Predicted Risk of Postoperative Stroke (PROPS), which is based on 26 variables. On- (ONCAB) and off-pump (OPCAB) patients were matched separately. Multiple logistic regression analysis with adjusted odds ratios (OR) was performed to identify operative variables associated with postoperative stroke. Results Among the ONCAB cohort, the single cross-clamp technique was associated with a decreased risk of stroke compared to the double clamp (cross clamp + partial clamp) technique (OR=0.385, p=0.044). Within the OPCAB cohort, there was no significant difference in stroke according to clamp use. Epiaortic ultrasound of the ascending aorta increased from 45.3% in 2002 to 89.4% in 2009. From 2002–2009, clamp use decreased from 97.7% of cases to 72.7%. Conclusions During ONCAB, the use of a single cross-clamp compared to the double clamp technique decreases the risk of postoperative stroke. The use of any aortic clamp has decreased and epiaortic ultrasound use has increased from 2002–2009, indicating a change in operative technique and surgeon awareness of the potential complications associated with manipulation of the aorta. PMID:23477689

  16. Committee Opinion No. 684: Delayed Umbilical Cord Clamping After Birth.

    Science.gov (United States)

    2017-01-01

    Delayed umbilical cord clamping appears to be beneficial for term and preterm infants. In term infants, delayed umbilical cord clamping increases hemoglobin levels at birth and improves iron stores in the first several months of life, which may have a favorable effect on developmental outcomes. There is a small increase in jaundice that requires phototherapy in this group of infants. Consequently, health care providers adopting delayed umbilical cord clamping in term infants should ensure that mechanisms are in place to monitor for and treat neonatal jaundice. In preterm infants, delayed umbilical cord clamping is associated with significant neonatal benefits, including improved transitional circulation, better establishment of red blood cell volume, decreased need for blood transfusion, and lower incidence of necrotizing enterocolitis and intraventricular hemorrhage. Delayed umbilical cord clamping was not associated with an increased risk of postpartum hemorrhage or increased blood loss at delivery, nor was it associated with a difference in postpartum hemoglobin levels or the need for blood transfusion. Given the benefits to most newborns and concordant with other professional organizations, the American College of Obstetricians and Gynecologists now recommends a delay in umbilical cord clamping in vigorous term and preterm infants for at least 30-60 seconds after birth. The ability to provide delayed umbilical cord clamping may vary among institutions and settings; decisions in those circumstances are best made by the team caring for the mother-infant dyad.

  17. Effect of delayed umbilical cord clamping on blood gas analysis.

    Science.gov (United States)

    Valero, Javier; Desantes, Domingo; Perales-Puchalt, Alfredo; Rubio, Juan; Diago Almela, Vicente J; Perales, Alfredo

    2012-05-01

    To ascertain if there are differences in umbilical cord blood gas analysis between immediate and delayed cord clamping. In a prospective observational study on 60 vaginally delivered healthy term newborns, we sampled umbilical cord blood immediately after delivery and at the time umbilical cord pulsation spontaneously ceased. There were significant decreases in pH, oxygen saturation (sO(2)), glycemia, oxygen content (ctO(2)), bicarbonate (HCO(3)(-)) and base excess (BE). Lactate and [Formula: see text] increased. Delayed cord clamping pH correlated with immediate cord clamping pH, [Formula: see text] , ctHb, sO(2) and time (r(2)=0.77, pcord clamping lactate was associated with immediate cord clamping lactate and time (r(2)=0.83, pcord clamping alters acid-base parameters and lactate values compared to immediate cord clamping. Those variations depend mainly on time, prior pH and lactate. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  18. Single electrode dynamic clamp with StdpC.

    Science.gov (United States)

    Samu, David; Marra, Vincenzo; Kemenes, Ildiko; Crossley, Michael; Kemenes, György; Staras, Kevin; Nowotny, Thomas

    2012-10-15

    Dynamic clamp is a powerful approach for electrophysiological investigations allowing researchers to introduce artificial electrical components into target neurons to simulate ionic conductances, chemical or electrotonic inputs or connections to other cells. Due to the rapidly changing and potentially large current injections during dynamic clamp, problematic voltage artifacts appear on the electrode used to inject dynamic clamp currents into a target neuron. Dynamic clamp experiments, therefore, typically use two separate electrodes in the same cell, one for recording membrane potential and one for injecting currents. The requirement for two independent electrodes has been a limiting factor for the use of dynamic clamp in applications where dual recordings of this kind are difficult or impossible to achieve. The recent development of an active electrode compensation (AEC) method has overcome some of these prior limitations, permitting artifact-free dynamic clamp experimentation with a single electrode. Here we describe an AEC method for the free dynamic clamp software StdpC. The AEC component of StdpC is the first such system implemented for the use of non-expert users and comes with a set of semi-automated configuration and calibration procedures that facilitate its use. We briefly introduce the AEC method and its implementation in StdpC and then validate it with an electronic model cell and in two different biological preparations.

  19. Control rods in LMFBRs: a physics assessment

    Energy Technology Data Exchange (ETDEWEB)

    McFarlane, H.F.; Collins, P.J.

    1982-08-01

    This physics assessment is based on roughly 300 control rod worth measurements in ZPPR from 1972 to 1981. All ZPPR assemblies simulated mixed-oxide LMFBRs, representing sizes of 350, 700, and 900 MWe. Control rod worth measurements included single rods, various combinations of rods, and Ta and Eu rods. Additional measurements studied variations in B/sub 4/C enrichment, rod interaction effects, variations in rod geometry, neutron streaming in sodium-filled channels, and axial worth profiles. Analyses were done with design-equivalent methods, using ENDF/B Version IV data. Some computations for the sensitivities to approximations in the methods have been included. Comparisons of these analyses with the experiments have allowed the status of control rod physics in the US to be clearly defined.

  20. Avoiding aortic clamping during CABG reduces postoperative stroke

    Science.gov (United States)

    Moss, Emmanuel; Puskas, John D; Thourani, Vinod H; Kilgo, Patrick; Chen, Edward P; Leshnower, Bradley G; Lattouf, Omar M; Guyton, Robert A.; Glas, Kathryn E; Halkos, Michael E.

    2014-01-01

    Objective The purpose of this study was to determine whether the incidence of postoperative stroke (PS) could be reduced by eliminating aortic clamping during CABG. Methods From 2002–2013, 12,079 patients underwent primary, isolated CABG at a single US academic institution. Aortic manipulation was completely avoided by using in-situ internal mammary arteries for inflow in 1,552 (12.9%) patients (no-touch), a clampless facilitating device (CFD) was used for proximal anastomoses in 1,548 (12.8%) patients, and aortic clamping was used in 8,979 (74.3%) patients. These strategies were assessed in a logistic regression model controlling for relevant variables. Results The overall incidence of PS was 1.4% (n=165), with an unadjusted incidence of 0.6% (n=10) in the no-touch group, 1.2% (n=18) in the CFD group, and 1.5% (n=137) in the clamp group (p<0.01 for no-touch vs clamp). The ratio of observed to expected stroke rate increased as the degree of aortic manipulation increased, from 0.48 in the no-touch group, to 0.61 in the CFD group, and 0.95 in the clamp group. Aortic clamping was independently associated with an increase in PS compared to a no-touch technique (AOR 2.50, p<0.01). When separated by CPB utilization, both the off-pump partial clamp and on-pump cross-clamp techniques increased the risk of PS compared to no-touch (AOR 2.52, p<0.01 and AOR 4.25, p<0.001, respectively). Conclusion A no-aortic touch technique has the lowest risk for postoperative stroke for patients undergoing CABG. Clamping the aorta during CABG increases the risk of PS, regardless of the severity of aortic disease. PMID:25293356

  1. Is "Delayed Umbilical Cord Clamping" Beneficial for Premature Newborns?

    Directory of Open Access Journals (Sweden)

    Amir-Mohammad Armanian

    2017-05-01

    Full Text Available Background: The appropriate moment for clamping the umbilical cord is controversial. Immediate cord clamping (ICC is an item of active management of the third stage of labor (AMTSL. Unclamped umbilical cord may cause inconvenience in preterm neonates because they commonly need some levels of emergent services. Some studies revealed delayed cord clamping (DCC of preterm neonates results in better health conditions like lower rates of respiratory distress syndrome (RDS, less morbidities in labor room and lower risk of postpartum hemorrhage. The aim of the present study was to determine the effect of delayed umbilical cord clamping on premature neonatal outcomes. Materials and Methods: In this single‑center randomized control trial study, sixty premature neonates (gestational age ≤ 34 weeks were randomly assigned to ICC (cord clamped at 5–10 seconds or DCC (30–45 seconds groups and followed up in neonatal intensive care unit (NICU. Primary outcomes were 1st and 5th minute Apgar score, average of level of hematocrit after birth, intra ventricle hemorrhage and need some levels of resuscitation. Results: Differences in demographic characteristics were not statistically significant. After birth, neonates who had delayed clamping had significantly higher mean hematocrit after at 4-hour of birth (49.58+5.15gr/dl vs. 46.58+5.40gr/dlin DCC vs. ICC groups, respectively (P=0.031. Delayed cord clamping reduced the duration of need to nasal continues positive airway pressure (NCPAP (86.7% and 60.0% in ICC and DCC groups, respectively, P= 0.039. Attractively, the results showed lower incidence of clinical sepsis in delayed cord clamping neonates (53.3% vs. 23.3% in ICC and DCC groups, respectively, P=0.033. Conclusion: Prematurity complications might decrease by delay umbilical cord clamping which improve the hematocrit, duration of need to NCPAP and incidence of clinical sepsis. Furthermore, DCC may have no negative impact on neonatal resuscitation.

  2. Solid-state-laser-rod holder

    Science.gov (United States)

    Gettemy, D.J.; Barnes, N.P.; Griggs, J.E.

    1981-08-11

    The disclosure relates to a solid state laser rod holder comprising Invar, copper tubing, and epoxy joints. Materials and coefficients of expansion of the components of the holder combine with the rod to produce a joint which will give before the rod itself will. The rod may be lased at about 70 to 80/sup 0/K and returned from such a temperature to room temperature repeatedly without its or the holder's destruction.

  3. 21 CFR 876.4270 - Colostomy rod.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Colostomy rod. 876.4270 Section 876.4270 Food and... GASTROENTEROLOGY-UROLOGY DEVICES Surgical Devices § 876.4270 Colostomy rod. (a) Identification. A colostomy rod is a device used during the loop colostomy procedure. A loop of colon is surgically brought out...

  4. Solitary waves on nonlinear elastic rods. II

    DEFF Research Database (Denmark)

    Sørensen, Mads Peter; Christiansen, Peter Leth; Lomdahl, P. S.

    1987-01-01

    In continuation of an earlier study of propagation of solitary waves on nonlinear elastic rods, numerical investigations of blowup, reflection, and fission at continuous and discontinuous variation of the cross section for the rod and reflection at the end of the rod are presented. The results...

  5. Phase behavior of colloidal silica rods

    NARCIS (Netherlands)

    Kuijk, A.; Byelov, D.; Petukhov, A.V.; van Blaaderen, A.; Imhof, A.

    2012-01-01

    Recently, a novel colloidal hard-rod-like model system was developed which consists of silica rods [Kuijk et al., JACS, 2011, 133, 2346]. Here, we present a study of the phase behavior of these rods, for aspect ratios ranging from 3.7 to 8.0. By combining real-space confocal laser scanning microscop

  6. Hydraulic Actuator for Ganged Control Rods

    Science.gov (United States)

    Thompson, D. C.; Robey, R. M.

    1986-01-01

    Hydraulic actuator moves several nuclear-reactor control rods in unison. Electromagnetic pump pushes liquid lithium against ends of control rods, forcing them out of or into nuclear reactor. Color arrows show lithium flow for reactor startup and operation. Flow reversed for shutdown. Conceived for use aboard spacecraft, actuator principle applied to terrestrial hydraulic machinery involving motion of ganged rods.

  7. Wear plates control rod guide tubes top internal reactor vessel C. N. VANDELLOS II; Desgaste placas tubos guia barras de control interno superior vasija del reactor C.N. Vandellos II

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    The guide tubes for control rods forming part of the upper internals of the reactor vessel, its function is to guide the control rod to permit its insertion in the reactor core. These guide tubes are suspended from the upper support plate which are fixed by bolts and extending to the upper core plate which is fastened by clamping bolts (split pin) to prevent lateral displacement of the guide tubes, while allowing axial expansion.

  8. Integral transform solutions of dynamic response of a clamped-clamped pipe conveying fluid

    Energy Technology Data Exchange (ETDEWEB)

    Gu Jijun; An Chen [Ocean Engineering Program, COPPE, Universidade Federal do Rio de Janeiro, CP 68508, Rio de Janeiro 21941-972 (Brazil); Duan Menglan [Offshore Oil/Gas Research Center, China University of Petroleum, Beijing 102249 (China); Levi, Carlos [Ocean Engineering Program, COPPE, Universidade Federal do Rio de Janeiro, CP 68508, Rio de Janeiro 21941-972 (Brazil); Su Jian, E-mail: sujian@nuclear.ufrj.br [Nuclear Engineering Program, COPPE, Universidade Federal do Rio de Janeiro, CP 68509, Rio de Janeiro 21941-972 (Brazil)

    2013-01-15

    Highlights: Black-Right-Pointing-Pointer Dynamic response of pipe conveying fluid was studied numerically. Black-Right-Pointing-Pointer The generalized integral transform technique (GITT) was applied. Black-Right-Pointing-Pointer Numerical solutions with automatic global accuracy control were obtained. Black-Right-Pointing-Pointer Excellent convergence behavior was shown. Black-Right-Pointing-Pointer Modal separation analysis was carried out and the influence of mass ratio was analyzed. - Abstract: Analysis of dynamic response of pipe conveying fluid is an important aspect in nuclear power plant design. In the present paper, dynamic response of a clamped-clamped pipe conveying fluid was solved by the generalized integral transform technique (GITT). The governing partial differential equation was transformed into a set of second-order ordinary differential equations which is then numerically solved by making use of the subroutine DIVPAG from IMSL Library. A thorough convergence analysis was performed to yield sets of reference results of the transverse deflection at different time and spanwise position. We found good agreement between the computed natural frequencies at mode 1-3 and those obtained by previous theoretical study. Besides, modal separation analysis was carried out and the influence of mass ratio on deflection and natural frequencies was qualitatively and quantitatively assessed.

  9. A clamp-like biohybrid catalyst for DNA oxidation

    Science.gov (United States)

    van Dongen, Stijn F. M.; Clerx, Joost; Nørgaard, Kasper; Bloemberg, Tom G.; Cornelissen, Jeroen J. L. M.; Trakselis, Michael A.; Nelson, Scott W.; Benkovic, Stephen J.; Rowan, Alan E.; Nolte, Roeland J. M.

    2013-11-01

    In processive catalysis, a catalyst binds to a substrate and remains bound as it performs several consecutive reactions, as exemplified by DNA polymerases. Processivity is essential in nature and is often mediated by a clamp-like structure that physically tethers the catalyst to its (polymeric) template. In the case of the bacteriophage T4 replisome, a dedicated clamp protein acts as a processivity mediator by encircling DNA and subsequently recruiting its polymerase. Here we use this DNA-binding protein to construct a biohybrid catalyst. Conjugation of the clamp protein to a chemical catalyst with sequence-specific oxidation behaviour formed a catalytic clamp that can be loaded onto a DNA plasmid. The catalytic activity of the biohybrid catalyst was visualized using a procedure based on an atomic force microscopy method that detects and spatially locates oxidized sites in DNA. Varying the experimental conditions enabled switching between processive and distributive catalysis and influencing the sliding direction of this rotaxane-like catalyst.

  10. The cardiovascular effects of aortic clamping and unclamping

    African Journals Online (AJOL)

    An increase in the slope of the Ea line represents an increase in ... increase. (for example as the subject exercises), stroke work ... aortic clamping is that afterload and blood pressure increase ..... nitroglycerine does not increase heart rate nor.

  11. Delay in Clamping Umbilical Cord Benefits Babies, Doctors Say

    Science.gov (United States)

    ... doctors' group said. Although delayed clamping increases the newborn's risk of jaundice that will require treatment, ACOG said there's no evidence that waiting increases the mother's risk of hemorrhage. The guidelines are to be published in the ...

  12. Planar patch-clamp force microscopy on living cells

    Energy Technology Data Exchange (ETDEWEB)

    Pamir, Evren [Center for Nano Science, Ludwig-Maximilians University, Amalienstr 54, 80799 Munich (Germany); George, Michael; Fertig, Niels [Nanion Technologies GmbH, Erzgiessereistr. 4, 80335 Munich (Germany); Benoit, Martin [Center for Nano Science, Ludwig-Maximilians University, Amalienstr 54, 80799 Munich (Germany)], E-mail: martin.benoit@physik.uni-muenchen.de

    2008-05-15

    Here we report a new combination of the patch-clamp technique with the atomic force microscope (AFM). A planar patch-clamp chip microstructured from borosilicate glass was used as a support for mechanical probing of living cells. The setup not only allows for immobilizing even a non-adherent cell for measurements of its mechanical properties, but also for simultaneously measuring the electrophysiological properties of a single cell. As a proof of principle experiment we measured the voltage-induced membrane movement of HEK293 and Jurkat cells in the whole-cell voltage clamp configuration. The results of these measurements are in good agreement with previous studies. By using the planar patch-clamp chip for immobilization, the AFM not only can image non-adhering cells, but also gets easily access to an electrophysiologically controlled cellular probe at low vibrational noise.

  13. [Time of cord clamping and neonatal complications, a prospective study].

    Science.gov (United States)

    Rincón, D; Foguet, A; Rojas, M; Segarra, E; Sacristán, E; Teixidor, R; Ortega, A

    2014-09-01

    To assess the effects of early or late clamping of the umbilical cord in term newborns, assessing the levels of hemoglobin, hematocrit, and ferritin, and their correlation with some of the complications. A prospective study of healthy newborns at term or born by dystotic or eutocic delivery in our hospital between May 2009 until May 2010. Patients were assigned according to the time of clamping, group 1 (clamping (g1: 111 mg/dl, g2: 125 mg/dl, g3: 173 mg/dl; pcord clamping is associated with an increase in hematocrit, hemoglobin and ferritin at 48 hours of life, as well as an increased risk of polycythemia present with symptoms. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  14. ELECTROMAGNETIC APPARATUS FOR MOVING A ROD

    Science.gov (United States)

    Young, J.N.

    1958-04-22

    An electromagnetic apparatus for moving a rod-like member in small steps in either direction is described. The invention has particular application in the reactor field where the reactor control rods must be moved only a small distance and where the use of mechanical couplings is impractical due to the high- pressure seals required. A neutron-absorbing rod is mounted in a housing with gripping uaits that engage the rod, and coils for magnetizing the gripping units to make them grip, shift, and release the rod are located outside the housing.

  15. Exploiting rod technology. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1990-06-01

    ROD development was proceeding apace until recent budgetary decisions caused funding support for ROD development to be drastically reduced. The funding which was originally provided by DARPA and the Balanced Technology Initiative (BTI) Office has been cut back to zero from $800K. To determine the aeroballistic coefficients of a candidate dart, ARDEC is currently supporting development out of its own 6.2 funds at about $100K. ARDEC has made slow progress toward achieving this end because of failures in the original dart during testing. It appears that the next dart design to be tested will diverge from the original concept visualized by DARPA and Science and Technology Associates (STA). STA, the design engineer, takes exception to these changes on the basis of inappropriate test conditions and insufficient testing. At this time, the full resolution of this issue will be difficult because of the current management structure, which separates the developer (ARDEC) from the designer (STA).

  16. Choosing the wire clamp microdrive for termosonic microwelding equipments

    Directory of Open Access Journals (Sweden)

    Lanin V. L.

    2010-06-01

    Full Text Available The article describes research of three types of wire clamp microdrive for termosonic microwelding equipment, covering an expanded range microconductors from 12,5 up to 75 mm. The most preferable, in the light of their high-speed and easy-programming qualities, proved to be the mechanisms of conductor clamp with piezoelement drives and the loading system based on "voice-coil" type electromagnet.

  17. Prehospital Emergency Inguinal Clamp Controls Hemorrhage in Cadaver Model

    Science.gov (United States)

    2013-07-01

    the CRoC preassembled for quick use. The clamp compresses the casualty’s tissues and is unat- tached to things like a litter. When screwed down, it is...for use on the battlefield to control difficult bleeds in the inguinal area. Study Design The study design was a sequence of experiments of clamp...temperature 4 hours before testing. The torso was rotated onto a wood block to intubate the aorta through a left thoracotomy incision. The thoracic aorta

  18. Lotus birth, a holistic approach on physiological cord clamping.

    Science.gov (United States)

    Zinsser, Laura A

    2017-09-04

    The positive effects of delayed cord clamping (DCC) has been extensively researched. DCC means: waiting at least one minute after birth before clamping and cutting the cord or till the pulsation has stopped. With physiological clamping and cutting (PCC) the clamping and cutting can happen at the earliest after the pulsation has stopped. With a Lotus birth, no clamping and cutting of the cord is done. A woman called Clair Lotus Day imitated the holistic approach of PCC from an anthropoid ape in 1974. The chimpanzee did not separate the placenta from the newborn. The aim of this case report is to discuss and learn a different approach in the third stage of labour. Three cases of Lotus birth by human beings were observed. All three women gave birth in an out-of-hospital setting and had ambulant postnatal care. The placenta was washed, salted and herbs were put on 2-3h post partum. The placenta was wrapped in something that absorbs the moisture. The salting was repeated with a degreasing frequency depending on moistness of the placenta. On life day six all three Lotus babies experiences a natural separation of the cord. All three Lotus birth cases were unproblematic, no special incidence occurred. One should differentiate between early cord clamping (ECC), delayed cord clamping (DCC) and physiological cord clamping (PCC). Lotus birth might lead to an optimisation of the bonding and attachment. Research is needed in the areas of both PCC and Lotus birth. Copyright © 2017 Australian College of Midwives. Published by Elsevier Ltd. All rights reserved.

  19. Mouse ganglion-cell photoreceptors are driven by the most sensitive rod pathway and by both types of cones.

    Directory of Open Access Journals (Sweden)

    Shijun Weng

    Full Text Available Intrinsically photosensitive retinal ganglion cells (iprgcs are depolarized by light by two mechanisms: directly, through activation of their photopigment melanopsin; and indirectly through synaptic circuits driven by rods and cones. To learn more about the rod and cone circuits driving ipRGCs, we made multielectrode array (MEA and patch-clamp recordings in wildtype and genetically modified mice. Rod-driven ON inputs to ipRGCs proved to be as sensitive as any reaching the conventional ganglion cells. These signals presumably pass in part through the primary rod pathway, involving rod bipolar cells and AII amacrine cells coupled to ON cone bipolar cells through gap junctions. Consistent with this interpretation, the sensitive rod ON input to ipRGCs was eliminated by pharmacological or genetic disruption of gap junctions, as previously reported for conventional ganglion cells. A presumptive cone input was also detectable as a brisk, synaptically mediated ON response that persisted after disruption of rod ON pathways. This was roughly three log units less sensitive than the rod input. Spectral analysis revealed that both types of cones, the M- and S-cones, contribute to this response and that both cone types drive ON responses. This contrasts with the blue-OFF, yellow-ON chromatic opponency reported in primate ipRGCs. The cone-mediated response was surprisingly persistent during steady illumination, echoing the tonic nature of both the rod input to ipRGCs and their intrinsic, melanopsin-based phototransduction. These synaptic inputs greatly expand the dynamic range and spectral bandpass of the non-image-forming visual functions for which ipRGCs provide the principal retinal input.

  20. Prototypical Rod Consolidation Demonstration Project. Phase 3, Final report: Volume 1, Cold checkout test report, Book 2

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    The objective of Phase 3 of the Prototypical Rod consolidation Demonstration Project (PRCDP) was to procure, fabricate, assemble, and test the Prototypical Rod consolidation System as described in the NUS Phase 2 Final Design Report. This effort required providing the materials, components, and fabricated parts which makes up all of the system equipment. In addition, it included the assembly, installation, and setup of this equipment at the Cold Test Facility. During the Phase 3 effort the system was tested on a component, subsystem, and system level. This volume 1, discusses the PRCDP Phase 3 Test Program that was conducted by the HALLIBURTON NUS Environmental Corporation under contract AC07-86ID12651 with the United States Department of Energy. This document, Volume 1, Book 2 discusses the following topics: Fuel Rod Extraction System Test Results and Analysis Reports and Clamping Table Test Results and Analysis Reports.

  1. Singular inextensible limit in the vibrations of post-buckled rods: Analytical derivation and role of boundary conditions

    KAUST Repository

    Neukirch, Sébastien

    2014-02-01

    In-plane vibrations of an elastic rod clamped at both extremities are studied. The rod is modeled as an extensible planar Kirchhoff elastic rod under large displacements and rotations. Equilibrium configurations and vibrations around these configurations are computed analytically in the incipient post-buckling regime. Of particular interest is the variation of the first mode frequency as the load is increased through the buckling threshold. The loading type is found to have a crucial importance as the first mode frequency is shown to behave singularly in the zero thickness limit in the case of prescribed axial displacement, whereas a regular behavior is found in the case of prescribed axial load. © 2013 Elsevier Ltd.

  2. Ultrasonic Rotary Motors Using Complex Transverse and Torsional Vibration Rods and Multiple Longitudinal Vibration Transducers

    Science.gov (United States)

    Suzuki, Atsuyuki; Kihara, Masaki; Katsumata, Yasuhiro; Ishii, Keisuke; Tsujino, Jiromaru

    2005-06-01

    The vibration and load characteristics of ultrasonic motors having (a) a torsional vibration cylinder with three bolt-clamped Langevin piezoelectric ceramic (PZT) longitudinal vibration transducers (BLTs) installed in the tangential direction and (b) a longitudinal vibration disk with three BLT transducers installed around a circular disk were studied. The center rod vibrates longitudinally and affects the load characteristics of the ultrasonic motor. Vibration distributions along a center rod were measured using a laser Doppler vibrometer. Revolution, electric input power, mechanical output power and efficiency were measured under various rotating torques. Maximum torque, revolution and efficiency of the ultrasonic motor with (a) a torsional vibration cylinder (a) were 0.75 Nm, 205 rpm and 1.68%, respectively, and (b) 0.32 Nm, 84 rpm and 1.68%, respectively, with a circular longitudinal vibration disk.

  3. Ventilation onset prior to umbilical cord clamping (physiological-based cord clamping) improves systemic and cerebral oxygenation in preterm lambs.

    Science.gov (United States)

    Polglase, Graeme R; Dawson, Jennifer A; Kluckow, Martin; Gill, Andrew W; Davis, Peter G; Te Pas, Arjan B; Crossley, Kelly J; McDougall, Annie; Wallace, Euan M; Hooper, Stuart B

    2015-01-01

    As measurement of arterial oxygen saturation (SpO2) is common in the delivery room, target SpO2 ranges allow clinicians to titrate oxygen therapy for preterm infants in order to achieve saturation levels similar to those seen in normal term infants in the first minutes of life. However, the influence of the onset of ventilation and the timing of cord clamping on systemic and cerebral oxygenation is not known. We investigated whether the initiation of ventilation, prior to, or after umbilical cord clamping, altered systemic and cerebral oxygenation in preterm lambs. Systemic and cerebral blood-flows, pressures and peripheral SpO2 and regional cerebral tissue oxygenation (SctO2) were measured continuously in apnoeic preterm lambs (126±1 day gestation). Positive pressure ventilation was initiated either 1) prior to umbilical cord clamping, or 2) after umbilical cord clamping. Lambs were monitored intensively prior to intervention, and for 10 minutes following umbilical cord clamping. Clamping the umbilical cord prior to ventilation resulted in a rapid decrease in SpO2 and SctO2, and an increase in arterial pressure, cerebral blood flow and cerebral oxygen extraction. Ventilation restored oxygenation and haemodynamics by 5-6 minutes. No such disturbances in peripheral or cerebral oxygenation and haemodynamics were observed when ventilation was initiated prior to cord clamping. The establishment of ventilation prior to umbilical cord clamping facilitated a smooth transition to systemic and cerebral oxygenation following birth. SpO2 nomograms may need to be re-evaluated to reflect physiological management of preterm infants in the delivery room.

  4. Ventilation onset prior to umbilical cord clamping (physiological-based cord clamping improves systemic and cerebral oxygenation in preterm lambs.

    Directory of Open Access Journals (Sweden)

    Graeme R Polglase

    Full Text Available As measurement of arterial oxygen saturation (SpO2 is common in the delivery room, target SpO2 ranges allow clinicians to titrate oxygen therapy for preterm infants in order to achieve saturation levels similar to those seen in normal term infants in the first minutes of life. However, the influence of the onset of ventilation and the timing of cord clamping on systemic and cerebral oxygenation is not known.We investigated whether the initiation of ventilation, prior to, or after umbilical cord clamping, altered systemic and cerebral oxygenation in preterm lambs.Systemic and cerebral blood-flows, pressures and peripheral SpO2 and regional cerebral tissue oxygenation (SctO2 were measured continuously in apnoeic preterm lambs (126±1 day gestation. Positive pressure ventilation was initiated either 1 prior to umbilical cord clamping, or 2 after umbilical cord clamping. Lambs were monitored intensively prior to intervention, and for 10 minutes following umbilical cord clamping.Clamping the umbilical cord prior to ventilation resulted in a rapid decrease in SpO2 and SctO2, and an increase in arterial pressure, cerebral blood flow and cerebral oxygen extraction. Ventilation restored oxygenation and haemodynamics by 5-6 minutes. No such disturbances in peripheral or cerebral oxygenation and haemodynamics were observed when ventilation was initiated prior to cord clamping.The establishment of ventilation prior to umbilical cord clamping facilitated a smooth transition to systemic and cerebral oxygenation following birth. SpO2 nomograms may need to be re-evaluated to reflect physiological management of preterm infants in the delivery room.

  5. High temperature control rod assembly

    Energy Technology Data Exchange (ETDEWEB)

    Vollman, Russell E. (Solana Beach, CA)

    1991-01-01

    A high temperature nuclear control rod assembly comprises a plurality of substantially cylindrical segments flexibly joined together in succession by ball joints. The segments are made of a high temperature graphite or carbon-carbon composite. The segment includes a hollow cylindrical sleeve which has an opening for receiving neutron-absorbing material in the form of pellets or compacted rings. The sleeve has a threaded sleeve bore and outer threaded surface. A cylindrical support post has a threaded shaft at one end which is threadably engaged with the sleeve bore to rigidly couple the support post to the sleeve. The other end of the post is formed with a ball portion. A hollow cylindrical collar has an inner threaded surface engageable with the outer threaded surface of the sleeve to rigidly couple the collar to the sleeve. the collar also has a socket portion which cooperates with the ball portion to flexibly connect segments together to form a ball and socket-type joint. In another embodiment, the segment comprises a support member which has a threaded shaft portion and a ball surface portion. The threaded shaft portion is engageable with an inner threaded surface of a ring for rigidly coupling the support member to the ring. The ring in turn has an outer surface at one end which is threadably engageably with a hollow cylindrical sleeve. The other end of the sleeve is formed with a socket portion for engagement with a ball portion of the support member. In yet another embodiment, a secondary rod is slidably inserted in a hollow channel through the center of the segment to provide additional strength. A method for controlling a nuclear reactor utilizing the control rod assembly is also included.

  6. Topological Mixing with Ghost Rods

    OpenAIRE

    2005-01-01

    Topological chaos relies on the periodic motion of obstacles in a two-dimensional flow in order to form nontrivial braids. This motion generates exponential stretching of material lines, and hence efficient mixing. Boyland et al. [P. L. Boyland, H. Aref, and M. A. Stremler, J. Fluid Mech. 403, 277 (2000)] have studied a specific periodic motion of rods that exhibits topological chaos in a viscous fluid. We show that it is possible to extend their work to cases where the motion of the stirring...

  7. Reactor control rod timing system. [LMFBR

    Science.gov (United States)

    Wu, P.T.K.

    1980-03-18

    A fluid driven jet-edge whistle timing system is described for control rods of a nuclear reactor for producing real-time detection of the timing of each control rod in its scram operation. An important parameter in reactor safety, particularly for liquid metal fast breeder reactors (LMFBR), is the time deviation between the time the control rod is released and the time the rod actually reaches the down position. The whistle has a nearly pure tone signal with center frequency (above 100 kHz) far above the frequency band in which the energy of the background noise is concentrated. Each control rod can be fitted with a whistle with a different frequency so that there is no ambiguity in differentiating the signal from each control rod.

  8. Automatic safety rod for reactors. [LMFBR

    Science.gov (United States)

    Germer, J.H.

    1982-03-23

    An automatic safety rod for a nuclear reactor containing neutron absorbing material and designed to be inserted into a reactor core after a loss-of-flow. Actuation is based upon either a sudden decrease in core pressure drop or the pressure drop decreases below a predetermined minimum value. The automatic control rod includes a pressure regulating device whereby a controlled decrease in operating pressure due to reduced coolant flow does not cause the rod to drop into the core.

  9. Acoustic loading effects on oscillating rod bundles

    Energy Technology Data Exchange (ETDEWEB)

    Lin, W.H.

    1980-01-01

    An analytical study of the interaction between an infinite acoustic medium and a cluster of circular rods is described. The acoustic field due to oscillating rods and the acoustic loading on the rods are first solved in a closed form. The acoustic loading is then used as a forcing function for rod responses, and the acousto-elastic couplings are solved simultaneously. Numerical examples are presented for several cases to illustrate the effects of various system parameters on the acoustic reaction force coefficients. The effect of the acoustic loading on the coupled eigenfrequencies are discussed.

  10. Pinching of PE pipes - Compilation report on standards, practices and experiences of clamping of PE gas pipes; Klaemning av PE-roer - Sammanstaellande rapport oever standarder, rutiner och erfarenheter kring klaemning av PE-gasroer

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-09-15

    Pinching is one method used to control or shut off the flow in a gas pipe. The pinching tool squeezes the tube with two round rods until the tube inner walls meet. The report present collected experiences and practices regarding clamping of Polyethylene (PE) tubes. The focus has been primarily to gather information regarding clamping of PE tubes with diameters greater than 160 mm and coated tubes (tube with the protective coating). The information presented in the report was mainly gathered through e-mail and phone contact with the gas company and tube manufacturers, but also organizations and consultancies have contacted. The information from each participant is reported separately as procedures and standards in clamping of PE pipes differ between countries and actors.

  11. Umbilical cord clamping. An analysis of a usual neonatological conduct.

    Science.gov (United States)

    Papagno, L

    1998-01-01

    Here we described a critical analysis of the neonatological procedure of early cord clamping, meaning this, within 40 seconds after birth. Fifty three cases are here analysed, in which this practice was not performed, but instead a late umbilical cord clamping was done after birth or after the cord had stopped beating. Variations in hematocrito values within 24 to 36 hours after birth were studied. A transitory polycithemia, with a maximum peak 12 hours post-delivery was observed. These values returned to normal levels between 24 and 36 hours after birth. K vitamin was not administered to any of the newborns. No pathology appeared related to this transitory polycithemia. In can be concluded that the late umbilical cord clamping represents no risk to the new-born and that the pathological phenomena described under these circumstances may be attributed to the increase in K vitamin dependent coagulation factors that are induced by the routinary administration of phitonadione to all normal newborns.

  12. Arterial Clamping Increases Central Renal Cryoablation Efficacy: An Animal Study

    DEFF Research Database (Denmark)

    Nonboe, Lasse Larsen; Nielsen, Tommy Kjaergaard; Høyer, Søren;

    2017-01-01

    INTRODUCTION: The minimally invasive treatment of small renal masses with cryoablation has become increasingly widespread during the past 15 years. Studies with long-term follow-up are beginning to emerge, showing good oncological control, however, tumors with a central and endophytic location seem...... to possess an increased risk of treatment failure. Such tumors are likely to be subjected to a high volume of blood giving thermal protection to the cancerous cells. Arterial clamping during freezing might reduce this effect but at the same time subject the kidney to ischemia. The aim of this study...... was to evaluate the effect of renal artery clamping during cryoablation in a porcine survival model. METHODS: Ten Danish Landrace pigs (approximately 40 kg) underwent bilateral laparoscopic cryoablation with clamping of the right renal artery during freezing. The cryoablation consisted of a standard double...

  13. [Advantage of delayed umbilical cord clamping in the newborn infant].

    Science.gov (United States)

    Menget, A; Mougey, C; Thiriez, G; Riethmuller, D

    2013-09-01

    The timing of umbilical cord clamping remains controversial. Although most maternity wards use the early clamping (5-15s), randomized studies and meta-analyses have demonstrated the benefit of delayed clamping for term and preterm newborn infants over the past 10 years. Indeed, placentofetal transfusion of 20-30 ml/kg in 2-3 min improves the iron status of term infants and prevents infant hypochromic anemia. Infant anemia is a public health problem in many developing countries. For preterm newborns, placental transfusion for 45 s or milking the cord for 15 s improves cardiovascular adaptation, with better hemodynamic stability, as well as decreased intraventricular hemorrhages, need for transfusion, and late-onset sepsis. A new look at this symbolic act is needed and professionals need to be persuaded of the importance of the "wait a minute" policy for a better physiological delivery.

  14. Using physiology to guide time to cord clamping.

    Science.gov (United States)

    Kluckow, Martin; Hooper, Stuart B

    2015-08-01

    Immediate clamping and cutting of the umbilical cord at birth has been the accepted standard of care for decades. The physiologic rationale relating umbilical cord clamping (UCC) to the events of the circulatory transition is not considered in arbitrarily recommended cord clamping times. Systematic review of early versus deferred UCC shows significant hemodynamic benefits to the deferred group. Mechanisms for this protective effect are considered in this review. The original concept of a placental transfusion with a volume load and prevention of low cardiac output relies on the physiological end point of the amount of blood transfused. The newer concept of an ordered physiological transition is increasingly supported. This model places aeration of the lungs and an increase in pulmonary blood flow back at the centre of the circulatory transition with timing of UCC being related to establishment of respiration. The need for "physiologically based" UCC is discussed. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  15. New active load voltage clamp for HF-link converters

    Energy Technology Data Exchange (ETDEWEB)

    Ljusev, P.; Andersen, M.A.E.

    2005-07-01

    This paper proposes a new active clamp for HF-link converters, which features very high efficiency by returning the clamped energy back to the primary side through a small auxiliary converter. It also increases the reliability of HF-link converters by providing an alternative load current path during malfunctions of the secondary bidirectional bridge. The feasibility of the approach is shown on audio power amplifier prototype. New integrated magnetics design is presented that incorporates both the main power and auxiliary transformer on the same magnetic core. (au)

  16. Plasma temperature clamping in filamentation laser induced breakdown spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Harilal, Sivanandan S.; Yeak, J.; Phillips, Mark C.

    2015-10-19

    Ultrafast laser filament induced breakdown spectroscopy is a very promising method for remote material detection. We present characteristics of plasmas generated in a metal target by laser filaments in air. Our measurements show that the temperature of the ablation plasma is clamped along the filamentation channel due to intensity clamping in a filament. Nevertheless, significant changes in radiation intensity are noticeable, and this is essentially due to variation in the number density of emitting atoms. The present results also partly explains the reason for the occurrence of atomic plume during fs LIBS in air compared to long-pulse ns LIBS.

  17. New active load voltage clamp for HF-link converters

    DEFF Research Database (Denmark)

    Ljusev, Petar; Andersen, Michael Andreas E.

    2005-01-01

    This paper proposes a new active clamp for HF-link converters, which features very high efficiency by returning the clamped energy back to the primary side through a small auxiliary converter. It also increases the reliability of HF-link converters by providing an alternative load current path du...... during malfunctions of the secondary bidirectional bridge. The feasibility of the approach is shown on audio power amplifier prototype. New integrated magnetics design is presented that incorporates both the main power and auxiliary transformer on the same magnetic core....

  18. The problem of isotropic rectangular plate with four clamped edges

    Indian Academy of Sciences (India)

    C Erdem İmrak; Ismail Gerdemeli

    2007-06-01

    The examination of the exact solution of the governing equation of the rectangular plate is important for many reasons. This report discusses in exact solution of the governing equation of an isotropic rectangular plate with four clamped edges. A numerical method for clamped isotropic rectangular plate under distributed loads and an exact solution of the governing equation in terms of trigonometric and hyperbolic function are given. Finally, an illustrative example is given and the results are compared with those reported earlier. This method is found to be easier and effective. The results show reasonable agreement with other available results, but with a simpler and practical approach.

  19. IVC CLAMP: infrahepatic inferior vena cava clamping during hepatectomy - a randomised controlled trial in an interdisciplinary setting

    Directory of Open Access Journals (Sweden)

    Reissfelder Christoph

    2009-10-01

    Full Text Available Abstract Background Intraoperative haemorrhage is a known predictor for perioperative outcome of patients undergoing hepatic resection. While anaesthesiological lowering of central venous pressure (CVP by fluid restriction is known to reduce bleeding during transection of the hepatic parenchyma its potential side effects remain poorly investigated. In theory it may have negative effects on kidney function and tissue perfusion and bears the risk to result in severe haemodynamic instability in case of profound intraoperative blood loss. The present randomised controlled trial evaluates efficacy and safety of infrahepatic inferior vena cava (IVC clamping as an alternative surgical technique to reduce CVP during hepatic resection. Methods/Design The proposed IVC CLAMP trial is a single-centre randomised controlled trial with a two-group parallel design. Patients and outcome-assessors are blinded for the treatment intervention. Patients undergoing elective hepatic resection due to any reason are enrolled in IVC CLAMP. All patients admitted to the Department of General-, Visceral-, and Transplant Surgery, University of Heidelberg for elective hepatic resection are consecutively screened for eligibility and written informed consent is obtained on the day before surgery. The primary objective of this trial is to assess and compare the amount of blood loss during hepatic resection in patients receiving surgical CVP reduction by clamping of the IVC as compared to anaesthesiological CVP without infrahepatic IVC clamping reduction. In addition to blood loss a set of general as well as surgical variables are analysed. Discussion This is a randomised controlled patient and observer blinded two-group parallel trial designed to assess efficacy and safety of infrahepatic IVC clamping during elective hepatectomy. Trial registration ClinicalTrials NCT00732979

  20. COMPARISON OF VIBRATION PERFORMANCE OF A SANDWICH CLAMPED-CLAMPED BEAM WITH MAGNETS VERSUS CONVENTIONAL CONSTRAINED DAMPING TREATMENTS

    Institute of Scientific and Technical Information of China (English)

    ZhengHuiming; HeZeng; LiMing; ZhaoGaoyu

    2004-01-01

    This paper investigates how the magnetic constrained layer damping (MCLD) treatment suppresses the displacement and acceleration resonant peak of a clamped-clamped beam. Because MCLI) treatment reduces input work and gives more dissipation energy, the vibration from external excitation can be effectively suppressed.The vibration reduction effects of MCLD and other conventional constrained damping treatments are also evaluated. In many cases, using MCLD treatments can yield smaller displacement and acceleration resonant peak especially in mode 1 compared to the other treatments without greatly changing the natural frequencies of the base beam.

  1. Viscoelasticity of suspensions of long, rigid rods

    NARCIS (Netherlands)

    Dhont, Jan K.G.; Briels, W.J.

    2003-01-01

    A microscopic theory for the viscoelastic behaviour of suspensions of rigid rods with excluded volume interactions is presented, which is valid in the asymptotic limit of very long and thin rods. Stresses arising from translational and rotational Brownian motion and direct interactions are calculate

  2. Study of the rod style SFRFQ structure

    CERN Document Server

    Yan Xue Qing; Chen J

    2002-01-01

    There is a problem about upper limit of energy in the RFQ structure, although it is a wonderful low-energy-suited high current accelerating structure. After proposing an improved rod style SFRFQ structure without reversed field, the author studies its energy gain and transverse motion. The rod style SFRFQ structure is roughly compared with diaphragm SFRFQ structure

  3. INOVASI SAMBUNGAN MEKANIS MENGGUNAKAN CLAMP BAJA UNTUK TULANGAN BETON

    Directory of Open Access Journals (Sweden)

    Parmo

    2015-12-01

    Full Text Available In the last few years, Indonesian urban growth has tends to be lead to the overground space. This was caused by the significant population increasement the lackness of land availability. The phenomenon is also marked with the increasing number of high-rise buildings and skyscrapers. However, high-rise buildings and skyscrapers have the potential dangers against earthquakes, even more Indonesia lay on an earthquake-prone areas. There are two main things that need to be considered in the planning of earthquake-resistant buildings, which is strength and ductility. Deformation capability and the connection strength between the reinforcement taken into consideration in the design of earthquake-resistant structures. From the steel clamp tensile test results for D13’s mechanical connection reinforcement, it gained 270.69 Mpa for yield strength, 351.45 MPa for ultimate tensile strength and 4757 kg for maximum load with 40% elongation. As for the D16’s mechanical connection reinforcement gained 217.80 MPa for yield strength, 327 605 MPa for ultimate tensile strength and 6717 kg for maximum load with 32% elongation. This study uses two pieces of steel clamp, but in order to obtain a better result then it need to be add more clamps while increasing the steel clamp material quality.

  4. Do not overlook an umbilical cord hernia before clamping.

    Science.gov (United States)

    Cizmeci, Mehmet Nevzat; Kanburoglu, Mehmet Kenan; Akelma, Ahmet Zulfikar; Tatli, Mustafa Mansur

    2013-08-01

    An umbilical cord hernia is a rare midline abdominal defect. These masses may be easily overlooked at birth, which may result in an intestinal injury due to careless proximal application of the cord clamp. Herein, we present a newborn infant with an umbilical cord hernia who was managed by primary closure of the lesion.

  5. A piezoelectric vibration harvester based on clamped-guided beams

    NARCIS (Netherlands)

    Wang, Z.; Matova, S.; Elfrink, R.; Jambunathan, M.; Nooijer, C. de; Schaijk, R. van; Vullers, R.J.M.

    2012-01-01

    The paper addresses the design, modeling, fabrication and experimental results of a piezoelectric energy harvester based on clamped-guided beams. The design is featured by shorter mass displacement and higher reliability than cantilever beams. Two separate sets of capacitors allow exploiting both te

  6. Nrl is required for rod photoreceptor development.

    Science.gov (United States)

    Mears, A J; Kondo, M; Swain, P K; Takada, Y; Bush, R A; Saunders, T L; Sieving, P A; Swaroop, A

    2001-12-01

    The protein neural retina leucine zipper (Nrl) is a basic motif-leucine zipper transcription factor that is preferentially expressed in rod photoreceptors. It acts synergistically with Crx to regulate rhodopsin transcription. Missense mutations in human NRL have been associated with autosomal dominant retinitis pigmentosa. Here we report that deletion of Nrl in mice results in the complete loss of rod function and super-normal cone function, mediated by S cones. The photoreceptors in the Nrl-/- retina have cone-like nuclear morphology and short, sparse outer segments with abnormal disks. Analysis of retinal gene expression confirms the apparent functional transformation of rods into S cones in the Nrl-/- retina. On the basis of these findings, we postulate that Nrl acts as a 'molecular switch' during rod-cell development by directly modulating rod-specific genes while simultaneously inhibiting the S-cone pathway through the activation of Nr2e3.

  7. The use of clamping grips and friction pads by tree frogs for climbing curved surfaces

    Science.gov (United States)

    Ji, Aihong; Yuan, Shanshan; Hill, Iain; Wang, Huan; Barnes, W. Jon P.; Dai, Zhendong; Sitti, Metin

    2017-01-01

    Most studies on the adhesive mechanisms of climbing animals have addressed attachment against flat surfaces, yet many animals can climb highly curved surfaces, like twigs and small branches. Here we investigated whether tree frogs use a clamping grip by recording the ground reaction forces on a cylindrical object with either a smooth or anti-adhesive, rough surface. Furthermore, we measured the contact area of fore and hindlimbs against differently sized transparent cylinders and the forces of individual pads and subarticular tubercles in restrained animals. Our study revealed that frogs use friction and normal forces of roughly a similar magnitude for holding on to cylindrical objects. When challenged with climbing a non-adhesive surface, the compressive forces between opposite legs nearly doubled, indicating a stronger clamping grip. In contrast to climbing flat surfaces, frogs increased the contact area on all limbs by engaging not just adhesive pads but also subarticular tubercles on curved surfaces. Our force measurements showed that tubercles can withstand larger shear stresses than pads. SEM images of tubercles revealed a similar structure to that of toe pads including the presence of nanopillars, though channels surrounding epithelial cells were less pronounced. The tubercles' smaller size, proximal location on the toes and shallow cells make them probably less prone to buckling and thus ideal for gripping curved surfaces. PMID:28228509

  8. Phase behavior and structure formation of hairy-rod supramolecules

    NARCIS (Netherlands)

    Subbotin, A; Stepanyan, R; Knaapila, M; Ikkala, O; ten Brinke, G

    2003-01-01

    Phase behavior and microstructure formation of rod and coil molecules, which can associate to form hairy-rod polymeric supramolecules, are addressed theoretically. Association induces considerable compatibility enhancement between the rod and coil molecules and various microscopically ordered struct

  9. Eulerian Formulation of Spatially Constrained Elastic Rods

    Science.gov (United States)

    Huynen, Alexandre

    Slender elastic rods are ubiquitous in nature and technology. For a vast majority of applications, the rod deflection is restricted by an external constraint and a significant part of the elastic body is in contact with a stiff constraining surface. The research work presented in this doctoral dissertation formulates a computational model for the solution of elastic rods constrained inside or around frictionless tube-like surfaces. The segmentation strategy adopted to cope with this complex class of problems consists in sequencing the global problem into, comparatively simpler, elementary problems either in continuous contact with the constraint or contact-free between their extremities. Within the conventional Lagrangian formulation of elastic rods, this approach is however associated with two major drawbacks. First, the boundary conditions specifying the locations of the rod centerline at both extremities of each elementary problem lead to the establishment of isoperimetric constraints, i.e., integral constraints on the unknown length of the rod. Second, the assessment of the unilateral contact condition requires, in principle, the comparison of two curves parametrized by distinct curvilinear coordinates, viz. the rod centerline and the constraint axis. Both conspire to burden the computations associated with the method. To streamline the solution along the elementary problems and rationalize the assessment of the unilateral contact condition, the rod governing equations are reformulated within the Eulerian framework of the constraint. The methodical exploration of both types of elementary problems leads to specific formulations of the rod governing equations that stress the profound connection between the mechanics of the rod and the geometry of the constraint surface. The proposed Eulerian reformulation, which restates the rod local equilibrium in terms of the curvilinear coordinate associated with the constraint axis, describes the rod deformed configuration

  10. Morphoelastic rods Part II: Growing birods

    Science.gov (United States)

    Lessinnes, Thomas; Moulton, Derek E.; Goriely, Alain

    2017-03-01

    The general problem of determining the shape and response of two attached growing elastic Kirchhoff rods is considered. A description of the kinematics of the individual interacting rods is introduced. Each rod has a given intrinsic shape and constitutive laws, and a map associating points on the two rods is defined. The resulting filamentary structure, a growing birod, can be seen as a new filamentary structure. This kinematic description is used to derive the general equilibrium equations for the shape of the rods under loads, or equivalently, for the new birod. It is shown that, in general, the birod is not simply a Kirchhoff rod but rather, due to the internal constraints, new effects can appear. The two-dimensional restriction is then considered explicitly and the limit for small deformation is shown to be equivalent to the classic Timsohenko bi-metallic strip problem. A number of examples and applications are presented. In particular, the problem of two attached rods with intrinsic helical shape and uniform growth is computed in detail and a host of new interesting solutions and bifurcations are observed.

  11. Granular materials interacting with thin flexible rods

    Science.gov (United States)

    Neto, Alfredo Gay; Campello, Eduardo M. B.

    2017-04-01

    In this work, we develop a computational model for the simulation of problems wherein granular materials interact with thin flexible rods. We treat granular materials as a collection of spherical particles following a discrete element method (DEM) approach, while flexible rods are described by a large deformation finite element (FEM) rod formulation. Grain-to-grain, grain-to-rod, and rod-to-rod contacts are fully permitted and resolved. A simple and efficient strategy is proposed for coupling the motion of the two types (discrete and continuum) of materials within an iterative time-stepping solution scheme. Implementation details are shown and discussed. Validity and applicability of the model are assessed by means of a few numerical examples. We believe that robust, efficiently coupled DEM-FEM schemes can be a useful tool to the simulation of problems wherein granular materials interact with thin flexible rods, such as (but not limited to) bombardment of grains on beam structures, flow of granular materials over surfaces covered by threads of hair in many biological processes, flow of grains through filters and strainers in various industrial segregation processes, and many others.

  12. Magnetically controlled growing rods for scoliosis surgery.

    Science.gov (United States)

    Metkar, Umesh; Kurra, Swamy; Quinzi, David; Albanese, Stephen; Lavelle, William F

    2017-02-01

    Early onset scoliosis can be both a disfiguring as well as a life threatening condition. When more conservative treatments fail, pediatric spinal surgeons are forced to consider operative interventions. Traditionally, these interventions have involved the insertion of a variety of implants into the patient with a limited number of anchor points controlling the spine. In the past, these pediatric patients have had multiple surgeries for elective lengthening of these devices to facilitate their growth while attempting to control the scoliosis. These patients often experience a physical and emotional toll from their multiple repeated surgeries. Growing spine techniques have also had a noted high complication rate due to implant dislodgement and infections. Recently, the development of non-invasively, self-lengthening growing rods has occurred. These devices have the potential to allow for the devices to be lengthened magnetically in a conscious patient in the surgeon's office. Areas covered: This review summarized previously published articles in the English literature using a key word search in PubMed for: 'magnetically controlled growing rods', 'Magec rods', 'magnetic growing rods' and 'growing rods'. Expert commentary: Magnetically controlled growing rods have an advantage over growing rods in lengthening the growing spine in the absence of repetitive surgeries.

  13. Control Rod Malfunction at the NRAD Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Thomas L. Maddock

    2010-05-01

    The neutron Radiography Reactor (NRAD) is a training, research, and isotope (TRIGA) reactor located at the INL. The reactor is normally shut down by the insertion of three control rods that drop into the core when power is removed from electromagnets. During a routine shutdown, indicator lights on the console showed that one of the control rods was not inserted. It was initially thought that the indicator lights were in error because of a limit switch that was out of adjustment. Through further testing, it was determined that the control rod did not drop when the scram switch was initially pressed. The control rod anomaly led to a six month shutdown of the reactor and an in depth investigation of the reactor protective system. The investigation looked into: scram switch operation, console modifications, and control rod drive mechanisms. A number of latent issues were discovered and corrected during the investigation. The cause of the control rod malfunction was found to be a buildup of corrosion in the control rod drive mechanism. The investigation resulted in modifications to equipment, changes to both operation and maintenance procedures, and additional training. No reoccurrences of the problem have been observed since corrective actions were implemented.

  14. Estimation of irradiated control rod worth

    Energy Technology Data Exchange (ETDEWEB)

    Varvayanni, M., E-mail: melina@ipta.demokritos.g [NCSR ' DEMOKRITOS' , PO Box 60228, 15310 Aghia Paraskevi (Greece); Catsaros, N. [NCSR ' DEMOKRITOS' , PO Box 60228, 15310 Aghia Paraskevi (Greece); Antonopoulos-Domis, M. [School of Electrical and Computer Engineering, Aristotle University of Thessaloniki, Thessaloniki (Greece)

    2009-11-15

    When depleted control rods are planned to be used in new core configurations, their worth has to be accurately predicted in order to deduce key design and safety parameters such as the available shutdown margin. In this work a methodology is suggested for the derivation of the distributed absorbing capacity of a depleted rod, useful in the case that the level of detail that is known about the irradiation history of the control rod does not allow an accurate calculation of the absorber's burnup. The suggested methodology is based on measurements of the rod's worth carried out in the former core configuration and on corresponding calculations based on the original (before first irradiation) absorber concentration. The methodology is formulated for the general case of the multi-group theory; it is successfully tested for the one-group approximation, for a depleted control rod of the Greek Research Reactor, containing five neutron absorbers. The computations reproduce satisfactorily the irradiated rod worth measurements, practically eliminating the discrepancy of the total rod worth, compared to the computations based on the nominal absorber densities.

  15. Granular materials interacting with thin flexible rods

    Science.gov (United States)

    Neto, Alfredo Gay; Campello, Eduardo M. B.

    2016-01-01

    In this work, we develop a computational model for the simulation of problems wherein granular materials interact with thin flexible rods. We treat granular materials as a collection of spherical particles following a discrete element method (DEM) approach, while flexible rods are described by a large deformation finite element (FEM) rod formulation. Grain-to-grain, grain-to-rod, and rod-to-rod contacts are fully permitted and resolved. A simple and efficient strategy is proposed for coupling the motion of the two types (discrete and continuum) of materials within an iterative time-stepping solution scheme. Implementation details are shown and discussed. Validity and applicability of the model are assessed by means of a few numerical examples. We believe that robust, efficiently coupled DEM-FEM schemes can be a useful tool to the simulation of problems wherein granular materials interact with thin flexible rods, such as (but not limited to) bombardment of grains on beam structures, flow of granular materials over surfaces covered by threads of hair in many biological processes, flow of grains through filters and strainers in various industrial segregation processes, and many others.

  16. Four- year thyroidectomy procedures: Ligasure Vs. clamp & tie

    Directory of Open Access Journals (Sweden)

    Pazoki AR

    2010-01-01

    Full Text Available "n Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:Arial; mso-bidi-theme-font:minor-bidi;} Background: The electrothermal bipolar vessel sealing system is an adjunct to the hemostatic technique, which has been successfully used in many abdominal operation, recently made available to thyroid surgery. The purpose of this was compare the outcomes of new hemostatic technique with traditional method of clamp and tie."n"nMethods: In this retrospective cross-sectional study has been done in surgery's wards of Milad & Rasul- Akram hospitals in Tehran, Iran. During three- year period between 2005-2008 all patients with different kind of pathology that need operation were assessed. Time duration of surgery and hospital stay and post surgery complication in two group, ligasure (n=45 and clamp & tie (n=145 were compared with each others."n"nResults: No difference was seen between two groups in time duration of surgery. Significant difference was seen in hospital stay and complications of surgery. Time of operation in Ligasure group was 132/22 minute and in clamp and tie group was 130/10 minute. There was found significant difference in duration of hospital stay and postoperative complication. Hypocalcemia were seen in two and 24 cases in Ligasure and Clamp & Tie group, respectively (p<0.05. Hospital stay was 2

  17. Tipping time of a quantum rod

    Energy Technology Data Exchange (ETDEWEB)

    Parrikar, Onkar [Birla Institute of Technology and Science-Pilani, Goa campus, Zuarinagar, Goa 4032726 (India)], E-mail: onkarsp@gmail.com

    2010-03-15

    The behaviour of a quantum rod, pivoted at its lower end on an impenetrable floor and restricted to moving in the vertical plane under the gravitational potential, is studied analytically under the approximation that the rod is initially localized to a 'small-enough' neighbourhood around the point of classical unstable equilibrium. It is shown that the rod evolves out of this neighbourhood. The time required for this to happen, i.e. the tipping time, is calculated using the semi-classical path integral. It is shown that equilibrium is recovered in the classical limit, and that our calculations are consistent with the uncertainty principle.

  18. High temperature control rod assembly

    Energy Technology Data Exchange (ETDEWEB)

    Vollman, R.E.

    1991-12-24

    This patent describes a control rod assembly for use in nuclear reactor control. It comprises segments, each the segment being made of a graphite composite material, each the segment having a chamber for containing neutron-absorbing material, wherein the chamber compromises a hollow cylindrical sleeve having a first end formed with an opening for receiving the neutron-absorbing material, and having a second end formed with a sleeve bore and an outer sleeve surface; a cylindrical weight-bearing support post positioned substantially centrally of the sleeve, the support post having a first end formed as a ball surface portion and a second end formed as a ball surface portion and a second end formed as a shaft, the shaft being engageable with the sleeve bore for rigidly coupling the support post axially within the hollow sleeve, a hollow cylindrical collar having a socket lip portion correspondingly shaped to receive the ball surface portion of an adjacent support post, and having an inner surface for engaging the outer sleeve surface on the second end of the sleeve to rigidly couple the collar to the sleeve.

  19. Timing of umbilical cord clamping: effect on iron endowment of the newborn and later iron status.

    Science.gov (United States)

    Chaparro, Camila M

    2011-11-01

    The optimal timing of umbilical cord clamping has been debated in the scientific literature for at least the last century, when cord clamping practices shifted from delayed towards immediate clamping. Recent research provides evidence for the beneficial effect of delayed cord clamping on infant iron status. The present review describes the physiological basis for the impact of cord clamping time on total body iron at birth and the relationship between birth body iron, as affected by cord clamping time, and iron status later in infancy. This research is discussed in the context of current clamping practices, which tend towards early cord clamping in most settings, as well as the high levels of anemia present in young infants in many countries worldwide. © 2011 International Life Sciences Institute.

  20. Gigaseal formation in patch clamping with applications of nanotechnology

    CERN Document Server

    Malboubi, Majid

    2014-01-01

    This book presents an investigation of gigaseal formation using micro/nanotechnology. The aims of the book are twofold. First, it explains the mechanisms of gigaseal formation using the latest discoveries. Second, it provides practical techniques for frequent formation of high resistance seals. The formation of a high-resistance electrical seal, also known as a gigaseal, between a cell membrane and a glass micropipette tip is essential in patch-clamp experiments. Even though four decades have passed since the introduction of the patch-clamping technique by Neher and Sakmann, gigaseal formation remains an obstacle in developing the high-throughput ion channel screening systems required by the pharmaceutical industry. Here the authors share their latest methods for achieving gigaseal formation and describe techniques that are highly desirable at both research and industrial levels. Nanotechnology has been found to be a powerful tool for studying and modifying glass micropipettes and in tackling the problem of g...

  1. A new configuration for multilevel converters with diode clamped topology

    DEFF Research Database (Denmark)

    Nami, A.; Zare, F.; Ledwich, G.

    2008-01-01

    of load changes which can avoid neutral point balancing problem in such converters. In addition, the presented topology is suitable for renewable energy systems to boost the low rectified output-voltage. In order to verify the proposed topology, steady state analysis, modelling and simulations are carried......Due to the increased use of renewable energy and power elctronic applications, more multilevel converters (MLC) are developed. A Neutral Point Clamped (NPC) inverter is one of the most used multilevel topologies for wind turbine (WT) and photovoltaic (PV) applications. One of the most crucial...... points in this type of converter is dc-voltage control. In this paper, a novel multi output dc-dc converter connected to a diode clamped topology is presented. This converter, for a given duty cycles, is able to regulate the capacitor voltage to provide an appropriate input voltage for NPC regardless...

  2. Active energy recovery clamping circuit to improve the performance of power converters

    Energy Technology Data Exchange (ETDEWEB)

    Whitaker, Bret; Barkley, Adam

    2017-05-09

    A regenerative clamping circuit for a power converter using clamping diodes to transfer charge to a clamping capacitor and a regenerative converter to transfer charge out of the clamping capacitor back to the power supply input connection. The regenerative converter uses a switch connected to the midpoint of a series connected inductor and capacitor. The ends of the inductor and capacitor series are connected across the terminals of the power supply to be in parallel with the power supply.

  3. Timing of umbilical cord clamping and neonatal haematological status.

    Science.gov (United States)

    Jaleel, Riffat; Deeba, Farah; Khan, Ayesha

    2009-07-01

    To determine the effect of delayed umbilical cord clamping on Hb (haemoglobin) and bilirubin levels of neonates and to identify newborn babies with anaemia and refer them for treatment. This Randomized Controlled Trial was conducted in the Department of Obstetrics and Gynaecology, Unit V, Dow Medical College and Lyari General Hospital and Department of Pathology, Lyari General Hospital, between 1st November, 2006 and 15th July, 2007. Patients admitted to labour ward were selected according to inclusion criteria of the study. They were randomly allocated to 2 groups. Group A included women in whom umbilical cord was clamped immediately after birth. In Group B, clamping was delayed until cessation of pulsations in the cord. After cutting the cord, sample of blood was collected from the cut end of cord of the newborn for Hb and bilirubin. After 6 hours of birth, another sample of blood was drawn from antecubital vein for serum bilirubin. Samples were sent to laboratory for analysis. All data were entered and analyzed using SPSS version 11. Two hundred women were studied, 100 in each of the 2 groups. Mean maternal Hb was 9.75 g/dl in Group A and 9.95 g/dl in Group B. The average neonatal Hb was 14.1 g/dl in Group A and 15.2 g/dl in Group B (p = 0.008). In all 49% neonates in Group A and 37% in Group B had Hb umbilical cord clamping at birth seems to be safe and can be expected to reduce the prevalence of anaemic newborn babies in our community.

  4. Indentation metrology of clamped, ultra-thin elastic sheets

    OpenAIRE

    Vella, Dominic; Davidovitch, Benny

    2017-01-01

    We study the indentation of ultrathin elastic sheets clamped to the edge of a circular hole. This classical setup has received considerable attention lately, being used by various experimental groups as a probe to measure the surface properties and stretching modulus of thin solid films. Despite the apparent simplicity of this method, the geometric nonlinearity inherent in the mechanical response of thin solid objects renders the analysis of the resulting data a nontrivial task. Importantly, ...

  5. Impact of AD995 alumina rods

    Energy Technology Data Exchange (ETDEWEB)

    Chhabildas, L.C.; Furnish, M.D.; Reinhart, W.D. [Sandia National Labs., Albuquerque, NM (United States); Grady, D.E. [Applied Research Associates, Inc., Albuquerque, NM (United States)

    1997-10-01

    Gas guns and velocity interferometric techniques have been used to determine the loading behavior of an AD995 alumina rod 19 mm in diameter by 75 mm and 150 mm long, respectively. Graded-density materials were used to impact both bare and sleeved alumina rods while the velocity interferometer was used to monitor the axial-velocity of the free end of the rods. Results of these experiments demonstrate that (1) a time-dependent stress pulse generated during impact allows an efficient transition from the initial uniaxial strain loading to a uniaxial stress state as the stress pulse propagates through the rod, and (2) the intermediate loading rates obtained in this configuration lie between split Hopkinson bar and shock-loading techniques.

  6. Computer simulation of rod-sphere mixtures

    CERN Document Server

    Antypov, D

    2003-01-01

    Results are presented from a series of simulations undertaken to investigate the effect of adding small spherical particles to a fluid of rods which would otherwise represent a liquid crystalline (LC) substance. Firstly, a bulk mixture of Hard Gaussian Overlap particles with an aspect ratio of 3:1 and hard spheres with diameters equal to the breadth of the rods is simulated at various sphere concentrations. Both mixing-demixing and isotropic-nematic transition are studied using Monte Carlo techniques. Secondly, the effect of adding Lennard-Jones particles to an LC system modelled using the well established Gay-Berne potential is investigated. These rod-sphere mixtures are simulated using both the original set of interaction parameters and a modified version of the rod-sphere potential proposed in this work. The subject of interest is the internal structure of the binary mixture and its dependence on density, temperature, concentration and various parameters characterising the intermolecular interactions. Both...

  7. Bouncing Balls and Hot Rod Races.

    Science.gov (United States)

    Tibbs, Peggy; Sherrill, Donna

    This paper presents the Bouncing Ball Experiment which models quadratic and exponential functions, and the Hot Rod Races activity that explores velocity and acceleration. Activities include directions for the use of TI-82 and TI-83 calculators. (YDS)

  8. POLYCYTHEMIA RISK IN NEONATES WITH DELAYED CORD CLAMPING

    Directory of Open Access Journals (Sweden)

    I Gusti Agung Ayu Sri Wulandari Pramana

    2013-07-01

    Full Text Available Normal 0 false false false EN-US X-NONE X-NONE Delayed Cord Clamping is still a controversial issue in the world of medicine. Until recently, the perfect times to do a Delayed Cord Clamping in various parts of the Earth in the world are still very diverse. There are a few things that became a major concern associated with Delayed Cord Clamping, one of which is the increase in blood volume due to an increase in the number of erythrocytes which led to occurrence of neonatal polycythemia which later can lead to various complications. Polycythemia in neonates is a situation where the value of venous blood hematokrit over 65% (0.65 or the amount of hemoglobin more than 22gr/Dl. However, to date the data from a variety of the latest research and analysis of the studies mention that the polycythemia that occurs in neonates with umbilical cord pinching the flush delay was mild polycythemia that can improve after 48 to 72 hours after the baby is born.

  9. Cleaning patch-clamp pipettes for immediate reuse

    Science.gov (United States)

    Kolb, I.; Stoy, W. A.; Rousseau, E. B.; Moody, O. A.; Jenkins, A.; Forest, C. R.

    2016-01-01

    Patch-clamp recording has enabled single-cell electrical, morphological and genetic studies at unparalleled resolution. Yet it remains a laborious and low-throughput technique, making it largely impractical for large-scale measurements such as cell type and connectivity characterization of neurons in the brain. Specifically, the technique is critically limited by the ubiquitous practice of manually replacing patch-clamp pipettes after each recording. To circumvent this limitation, we developed a simple, fast, and automated method for cleaning glass pipette electrodes that enables their reuse within one minute. By immersing pipette tips into Alconox, a commercially-available detergent, followed by rinsing, we were able to reuse pipettes 10 times with no degradation in signal fidelity, in experimental preparations ranging from human embryonic kidney cells to neurons in culture, slices, and in vivo. Undetectable trace amounts of Alconox remaining in the pipette after cleaning did not affect ion channel pharmacology. We demonstrate the utility of pipette cleaning by developing the first robot to perform sequential patch-clamp recordings in cell culture and in vivo without a human operator. PMID:27725751

  10. MEMS-based clamp with a passive hold function for precision position retaining of micro manipulators

    NARCIS (Netherlands)

    Brouwer, D.M.; Jong, de B.R.; Boer, de M.J.; Jansen, H.V.; Dijk, van J.; Krijnen, G.J.M.; Soemers, H.M.J.R.

    2009-01-01

    In this paper the design, modeling and fabrication of a precision MEMS-based clamp with a relatively large clamping force are presented. The purpose of the clamp is to mechanically fix a six-degree-of-freedom (DOF) MEMS-based sample manipulator (Brouwer et al J. Int. Soc. Precis. Eng. Nanotechnol. s

  11. MEMS-based clamp with a passive hold function for precision position retaining of micromanipulators

    NARCIS (Netherlands)

    Brouwer, Dannis Michel; de Jong, B.R.; de Boer, Meint J.; Jansen, Henricus V.; van Dijk, Johannes A.G.M.; van Dijk, Johannes; Krijnen, Gijsbertus J.M.; Soemers, Herman

    2009-01-01

    In this paper the design, modeling and fabrication of a precision MEMS-based clamp with arelatively large clamping force are presented. The purpose of the clamp is to mechanically fixa six-degree-of-freedom (DOF) MEMS-based sample manipulator (Brouwer et al J. Int. Soc. Precis. Eng. Nanotechnol. sub

  12. File list: Oth.ALL.10.Clamp.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.ALL.10.Clamp.AllCell dm3 TFs and others Clamp All cell types SRX159170,SRX15917...2,SRX159174,SRX159166,SRX159173 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Oth.ALL.10.Clamp.AllCell.bed ...

  13. File list: Oth.ALL.05.Clamp.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.ALL.05.Clamp.AllCell dm3 TFs and others Clamp All cell types SRX159172,SRX15917...0,SRX159174,SRX159166,SRX159173 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Oth.ALL.05.Clamp.AllCell.bed ...

  14. File list: Oth.CeL.10.Clamp.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.CeL.10.Clamp.AllCell dm3 TFs and others Clamp Cell line SRX159170,SRX159172,SRX...159174,SRX159166,SRX159173 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Oth.CeL.10.Clamp.AllCell.bed ...

  15. File list: Oth.CeL.20.Clamp.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.CeL.20.Clamp.AllCell dm3 TFs and others Clamp Cell line SRX159172,SRX159170,SRX...159174,SRX159166,SRX159173 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Oth.CeL.20.Clamp.AllCell.bed ...

  16. File list: Oth.ALL.50.Clamp.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.ALL.50.Clamp.AllCell dm3 TFs and others Clamp All cell types SRX159172,SRX15917...0,SRX159174,SRX159166,SRX159173 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Oth.ALL.50.Clamp.AllCell.bed ...

  17. File list: Oth.ALL.20.Clamp.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.ALL.20.Clamp.AllCell dm3 TFs and others Clamp All cell types SRX159172,SRX15917...0,SRX159174,SRX159166,SRX159173 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Oth.ALL.20.Clamp.AllCell.bed ...

  18. File list: Oth.CeL.05.Clamp.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Oth.CeL.05.Clamp.AllCell dm3 TFs and others Clamp Cell line SRX159172,SRX159170,SRX...159174,SRX159166,SRX159173 http://dbarchive.biosciencedbc.jp/kyushu-u/dm3/assembled/Oth.CeL.05.Clamp.AllCell.bed ...

  19. The early effects of delayed cord clamping in term infants born to Libyan mothers

    NARCIS (Netherlands)

    Emhamed, Musbah Omar; van Rheenen, Patrick; Brabin, Bernard J

    2004-01-01

    This study was conducted to evaluate the haematological effects of the timing of umbilical cord clamping in term infants 24 h after birth in Libya. Mother-infant pairs were randomly assigned to early cord clamping (within 10s after delivery) or delayed clamping (after the cord stopped pulsating). Ma

  20. Double-clad nuclear fuel safety rod

    Science.gov (United States)

    McCarthy, William H.; Atcheson, Donald B.; Vaidyanathan, Swaminathan

    1984-01-01

    A device for shutting down a nuclear reactor during an undercooling or overpower event, whether or not the reactor's scram system operates properly. This is accomplished by double-clad fuel safety rods positioned at various locations throughout the reactor core, wherein melting of a secondary internal cladding of the rod allows the fuel column therein to shift from the reactor core to place the reactor in a subcritical condition.

  1. Microelectrophoresis of Silica Rods Using Confocal Microscopy.

    Science.gov (United States)

    Bakker, Henriëtte E; Besseling, Thijs H; Wijnhoven, Judith E G J; Helfferich, Peter H; van Blaaderen, Alfons; Imhof, Arnout

    2017-01-31

    The electrophoretic mobility and the zeta potential (ζ) of fluorescently labeled colloidal silica rods, with an aspect ratio of 3.8 and 6.1, were determined with microelectrophoresis measurements using confocal microscopy. In the case where the colloidal particles all move at the same speed parallel to the direction of the electric field, we record a xyz-stack over the whole depth of the capillary. This method is faster and more robust compared to taking xyt-series at different depths inside the capillary to obtain the parabolic flow profile, as was done in previous work from our group. In some cases, rodlike particles do not move all at the same speed in the electric field, but exhibit a velocity that depends on the angle between the long axis of the rod and the electric field. We measured the orientation-dependent velocity of individual silica rods during electrophoresis as a function of κa, where κ(-1) is the double layer thickness and a is the radius of the rod associated with the diameter. Thus, we determined the anisotropic electrophoretic mobility of the silica rods with different sized double layers. The size of the double layer was tuned by suspending silica rods in different solvents at different electrolyte concentrations. We compared these results with theoretical predictions. We show that even at already relatively high κa when the Smoluchowski limiting law is assumed to be valid (κa > 10), an orientation dependent velocity was measured. Furthermore, we observed that at decreasing values of κa the anisotropy in the electrophoretic mobility of the rods increases. However, in low polar solvents with κa < 1, this trend was reversed: the anisotropy in the electrophoretic mobility of the rods decreased. We argue that this decrease is due to end effects, which was already predicted theoretically. When end effects are not taken into account, this will lead to strong underestimation of the experimentally determined zeta potential.

  2. High Power Performance of Rod Fiber Amplifiers

    DEFF Research Database (Denmark)

    Johansen, Mette Marie; Michieletto, Mattia; Kristensen, Torben

    2015-01-01

    An improved version of the DMF rod fiber is tested in a high power setup delivering 360W of stable signal power. Multiple testing degrades the fiber and transverse modal instability threshold from >360W to ~290W.......An improved version of the DMF rod fiber is tested in a high power setup delivering 360W of stable signal power. Multiple testing degrades the fiber and transverse modal instability threshold from >360W to ~290W....

  3. IMPACT CONICAL ROD ON HARD LIMITER

    Directory of Open Access Journals (Sweden)

    Ulitin G.

    2014-12-01

    Full Text Available The problem is considered of longitudinal impact conical rod in article. A recommendation on the use of the approximate method of calculation is based on an analysis of the influence of design parameters on the value of the main oscillation frequency. There was obtained an equation of the displacement and stress of the rod. Engineering dependence has been proposed to determine the maximum force in the impact section.

  4. Self-diagnosing braided composite rod

    OpenAIRE

    Fangueiro, Raúl; Zdraveva, E.; Pereira, Cristiana Gonilho; Ferreira, A; Lanceros-Méndez, S.

    2010-01-01

    This paper presents the development of a braided reinforced composite rod (BCR) able to both reinforce and monitor the stress state of concrete structures. Carbon fibers have been used as sensing and reinforcing materials along with glass fiber. Various composites rods have been produced using an author patented technique based on a modified conventional braiding machine. The materials investigated were prepared with different carbon fiber content as follows: BCR2 (77% glass/23...

  5. Measurements of control rod efficiency in RBMK critical assembly upon dropping of the rods

    Energy Technology Data Exchange (ETDEWEB)

    Zhitarev, V. E., E-mail: vejitarev@nnrd.kiae.su; Kachanov, V. M.; Sergevnin, A. Yu.; Lebedev, G. V., E-mail: lgv2004@mail.ru [National Research Center Kurchatov Institute (Russian Federation)

    2014-12-15

    The efficiency of control rods in the RBMK critical assembly was measured in the case where one manual-control rod (MCR) is dropped from a steady critical state, and several other MCRs were additionally dropped after 44 s. The measured number of neutrons in the assembly during and after dropping of the rods was used to calculate the efficiency values of the rods by solution of the system of point kinetics equations. A series of methods of the initial data treatment for determination of the desired values of reactivity without the calculated corrections were used.

  6. Measurements of control rod efficiency in RBMK critical assembly upon dropping of the rods

    Science.gov (United States)

    Zhitarev, V. E.; Kachanov, V. M.; Sergevnin, A. Yu.; Lebedev, G. V.

    2014-12-01

    The efficiency of control rods in the RBMK critical assembly was measured in the case where one manual-control rod (MCR) is dropped from a steady critical state, and several other MCRs were additionally dropped after 44 s. The measured number of neutrons in the assembly during and after dropping of the rods was used to calculate the efficiency values of the rods by solution of the system of point kinetics equations. A series of methods of the initial data treatment for determination of the desired values of reactivity without the calculated corrections were used.

  7. High-throughput rod-induced electrospinning

    Science.gov (United States)

    Wu, Dezhi; Xiao, Zhiming; Teh, Kwok Siong; Han, Zhibin; Luo, Guoxi; Shi, Chuan; Sun, Daoheng; Zhao, Jinbao; Lin, Liwei

    2016-09-01

    A high throughput electrospinning process, directly from flat polymer solution surfaces induced by a moving insulating rod, has been proposed and demonstrated. Different rods made of either phenolic resin or paper with a diameter of 1-3 cm and a resistance of about 100-500 MΩ, has been successfully utilized in the process. The rod is placed approximately 10 mm above the flat polymer solution surface with a moving speed of 0.005-0.4 m s-1 this causes the solution to generate multiple liquid jets under an applied voltage of 15-60 kV for the tip-less electrospinning process. The local electric field induced by the rod can boost electrohydrodynamic instability in order to generate Taylor cones and liquid jets. Experimentally, it is found that a large rod diameter and a small solution-to-rod distance can enhance the local electrical field to reduce the magnitude of the applied voltage. In the prototype setup with poly (ethylene oxide) polymer solution, an area of 5 cm  ×  10 cm and under an applied voltage of 60 kV, the maximum throughput of nanofibers is recorded to be approximately144 g m-2 h-1.

  8. Rigid rod anchored to infinite membrane.

    Science.gov (United States)

    Guo, Kunkun; Qiu, Feng; Zhang, Hongdong; Yang, Yuliang

    2005-08-15

    We investigate the shape deformation of an infinite membrane anchored by a rigid rod. The density profile of the rod is calculated by the self-consistent-field theory and the shape of the membrane is predicted by the Helfrich membrane elasticity theory [W. Helfrich, Z. Naturforsch. 28c, 693 (1973)]. It is found that the membrane bends away from the rigid rod when the interaction between the rod and the membrane is repulsive or weakly attractive (adsorption). However, the pulled height of the membrane at first increases and then decreases with the increase of the adsorption strength. Compared to a Gaussian chain with the same length, the rigid rod covers much larger area of the membrane, whereas exerts less local entropic pressure on the membrane. An evident gap is found between the membrane and the rigid rod because the membrane's curvature has to be continuous. These behaviors are compared with that of the flexible-polymer-anchored membranes studied by previous Monte Carlo simulations and theoretical analysis. It is straightforward to extend this method to more complicated and real biological systems, such as infinite membrane/multiple chains, protein inclusion, or systems with phase separation.

  9. Long-Rod Moving-Plate Interaction

    Science.gov (United States)

    Partom, Y.

    2002-07-01

    Understanding the mechanics of interaction of a long rod projectile with a forward moving plate at an angle is essential to understanding long rod interaction with an explosive reactive armor cassette. To investigate the mechanics of such an interaction we use AUTODIN2D/EULER in plane geometry, although the problem is 3D. We assume that this is a satisfactory approximation, as we're only interested in the main features, and are not comparing fine details to experimental results. From the simulations we learn that the interaction never reaches steady state. Initially each material splits into two streams, and the interaction plane is perpendicular to the rod. But with time the interaction plane rotates slowly, until it becomes parallel to the rod, which is then able to continue moving forward without interruption. During this process interacting rod material of length DeltaL is diverted at an angle and becomes ineffective for penetrating the main target. We made many such runs to determine the dependence of DeltaL on the parameters of the problem. This dependence makes it possible to predict DeltaL for a variety of rod-plate situations.

  10. Topological optimisation of rod-stirring devices

    CERN Document Server

    Finn, Matthew D

    2011-01-01

    There are many industrial situations where rods are used to stir a fluid, or where rods repeatedly stretch a material such as bread dough or taffy. The goal in these applications is to stretch either material lines (in a fluid) or the material itself (for dough or taffy) as rapidly as possible. The growth rate of material lines is conveniently given by the topological entropy of the rod motion. We discuss the problem of optimising such rod devices from a topological viewpoint. We express rod motions in terms of generators of the braid group, and assign a cost based on the minimum number of generators needed to write the braid. We show that for one cost function -- the topological entropy per generator -- the optimal growth rate is the logarithm of the golden ratio. For a more realistic cost function,involving the topological entropy per operation where rods are allowed to move together, the optimal growth rate is the logarithm of the silver ratio, $1+\\sqrt{2}$. We show how to construct devices that realise th...

  11. 木薯收获机夹持输送机构设计与力学分析%Design and Mechanics Analysis of Clamping-Conveying Mechanism of Cassava Harvester

    Institute of Scientific and Technical Information of China (English)

    余瑞明; 廖宇兰; 刘世豪; 王涛; 袁成宇

    2015-01-01

    针对现有挖拔式木薯收获机夹持输送机构出现夹持掉带掉薯、夹持对中困难及木薯茎秆难以进入夹持输送机构等问题,研究设计了夹持输送机构。该机构采用拉簧安装在移动杆凹槽内,移动杆与机架间为移动副连接的方式夹紧木薯茎秆,并将其与摇杆与机架间为转动副连接的方式进行了对比分析。结果表明:移动副连接使拉簧的拉力全部提供为夹持力,无拉力损失,夹持力最大;同时,自动调节带间距,夹持牢固。根据土薯生物环境特性,设计了夹持轮、带轮、夹持带、张紧装置和导向装置等主要结构,并对各结构进行了分析,确定了主要结构参数。根据木薯块根拔起时的速度分解图,建立了块根拔起时的力学模型,且通过分析推导得到了夹持输送机构对块根的拔起力和对茎秆的夹持力计算公式。该研究对于快速拔出、输送薯块、减少薯块损失、降低伤薯率、提高挖拔式木薯收获机整机性能具有重要意义。%Aiming at the existing problems of dropping off during clamping,dropping off of cassava,difficulty to clamp in the middle point,difficulty to feed cassava stem to clamping-conveying mechanism of digging-pulling cassava harvest,a kind of clamping-conveying mechanism is designed.Tension-spring is installed inside a shift rod groove.The cassava stem is clamped tightly between wheels being installed the shifting rod and frame.The shifting rod can shift on the frame by shifting pair.Compare with the revolving pair between the rocker and frame,the shifting pair make the power of ten-sion-spring turn to clamping-power fully,no any loss,get maximum clamping force.At the same time the spacing of two belts can be adjusted automatically,and the cassava stem may be clamped firmly.According to the biological and environ-mental characteristics of cassava,main structure such as clamping-wheel,belt-wheel,clamping

  12. Investigation of the Dynamics of a Clamped-Clamped Microbeam Near the Third Mode Using a Partial Electrode

    KAUST Repository

    Masri, Karim M.

    2014-08-17

    We present an investigation of the dynamics of a clamped-clamped microbeam excited electrostatically near its third mode. To maximize the response at the third mode, a partial electrode configuration is utilized. A multi-mode Galerkin method is used to develop a reduced order model (ROM) of the beam. A shooting method to find the periodic motion is utilized to generate frequency response curves. The curves show hardenining behavior and dynamic pull-in. We show that the dynamic amplitude of the partial configuration is higher than that of a full electrode configuration. These results are promising for the use of higher-order modes for mass detection and for ultra sensitive resonant sensors.

  13. International symposium on fuel rod simulators: development and application

    Energy Technology Data Exchange (ETDEWEB)

    McCulloch, R.W. (comp.)

    1981-05-01

    Separate abstracts are included for each of the papers presented concerning fuel rod simulator operation and performance; simulator design and evaluation; clad heated fuel rod simulators and fuel rod simulators for cladding investigations; fuel rod simulator components and inspection; and simulator analytical modeling. Ten papers have previously been input to the Energy Data Base.

  14. Timing of umbilical cord clamping: new thoughts on an old discussion.

    Science.gov (United States)

    Arca, Gemma; Botet, Francesc; Palacio, Montse; Carbonell-Estrany, Xavier

    2010-11-01

    The optimal time to clamp the umbilical cord in preterm and full-term neonates after birth continues to be a matter of debate. A review of randomised controlled trials comparing the effects of early versus late cord clamping on maternal and infant outcomes was performed to assess data in favor of immediate or delayed clamping. Although there is no conclusive evidence, delayed cord clamping seems to be beneficial in preterm and full-term neonates without compromising the initial postpartum adaptation phase or affecting the mother in the short term. However, further randomised clinical studies are needed to confirm the benefits of delayed cord clamping.

  15. Local Fuel Rod Crud Prediction Tool Applications

    Energy Technology Data Exchange (ETDEWEB)

    Krammen, Michael A.; Karoutas, Zeses E.; Wang, Guoqiang; Young, Michael Y

    2009-06-15

    A code system with attendant methods has been developed for modeling local fuel rod crud. This tool is used to perform the Crud Induced Localized Corrosion (CILC) risk assessment recommended by the EPRI crud and corrosion guidelines, which were developed in response to the INPO zero fuel failures by 2010 initiatives. The methodology is in production use. This paper will describe the range of problems the methodology has already been applied to and the especial pertinence to low duty fuel applications. The methodology begins with Computational Fluid Dynamics (CFD) computations over a fuel assembly grid span. The CFD results provide detailed relative variations in local heat transfer coefficient over the grid span. These very local relative variations are used to determine very local thermal hydraulic conditions over the entire axial length of every fuel rod in a reactor core over the life of the rod in reactor. The expansion using the local relative variations is currently accomplished with the HIDUTYDRV code. The very local thermal hydraulic conditions are combined with reactor coolant crud concentrations derived from EPRI BOA analysis as input to models for predicting very local fuel rod crud deposition. The reactor coolant crud concentrations are determined over each reactor cycle by reactor system wide crud mass balance calculations. The reactor coolant crud concentrations are used to calculate local crud thickness using mass transfer models which are a function of the local thermal conditions. The advanced crud deposition models also include models for calculating local crud dryout. Local crud deposition and crud dryout are strongly dependent on very local boiling or steaming, which are predicted through the translation of the CFD results. The local crud thickness and degree of local crud dryout are key factors in determining the margin or risk for local fuel rod cladding crud induced fuel failure. The development and first application of these methods was in

  16. Genomic evidence for rod monochromacy in sloths and armadillos suggests early subterranean history for Xenarthra.

    Science.gov (United States)

    Emerling, Christopher A; Springer, Mark S

    2015-02-07

    Rod monochromacy is a rare condition in vertebrates characterized by the absence of cone photoreceptor cells. The resulting phenotype is colourblindness and low acuity vision in dim-light and blindness in bright-light conditions. Early reports of xenarthrans (armadillos, sloths and anteaters) suggest that they are rod monochromats, but this has not been tested with genomic data. We searched the genomes of Dasypus novemcinctus (nine-banded armadillo), Choloepus hoffmanni (Hoffmann's two-toed sloth) and Mylodon darwinii (extinct ground sloth) for retinal photoreceptor genes and examined them for inactivating mutations. We performed PCR and Sanger sequencing on cone phototransduction genes of 10 additional xenarthrans to test for shared inactivating mutations and estimated the timing of inactivation for photoreceptor pseudogenes. We concluded that a stem xenarthran became an long-wavelength sensitive-cone monochromat following a missense mutation at a critical residue in SWS1, and a stem cingulate (armadillos, glyptodonts and pampatheres) and stem pilosan (sloths and anteaters) independently acquired rod monochromacy early in their evolutionary history following the inactivation of LWS and PDE6C, respectively. We hypothesize that rod monochromacy in armadillos and pilosans evolved as an adaptation to a subterranean habitat in the early history of Xenarthra. The presence of rod monochromacy has major implications for understanding xenarthran behavioural ecology and evolution.

  17. Clamping stiffness and its influence on load distribution between paired internal spinal fixation devices.

    Science.gov (United States)

    Rohlmann, A; Calisse, J; Bergmann, G; Radvan, J; Mayer, H M

    1996-06-01

    The load distribution between two internal spinal fixation devices depends, besides other factors, on their stiffness. The stiffness ranges were determined experimentally for the clamps of the AO internal fixator with lateral nut and with posterior nut as well as for the clamps of the SOCON fixator. The stiffness of eight devices each differed by a factor of 3.1 for the clamp with lateral nut, by a factor of 1.5 for the clamp with posterior nut, and by a factor of 1.4 for the clamp of the SOCON fixator. For the AO clamp with lateral nut, the influence of the nut-tightening torque on the stiffness was determined. Using instrumented internal spinal fixation devices mounted to plastic vertebrae and simulating a corpectomy, the load distribution between the implants was measured for different tightening torques. It could be shown that, for the AO internal fixator whose clamps have a lateral nut, a nut-tightening torque > 5 Nm has only a negligible influence on load-sharing between the implants. Tooth damage occurs when the teeth of the clamp body and clamping jaw of the clamp with lateral nut do not gear together exactly, which leads to changes in the clamping stiffness and load-sharing between the two implants.

  18. The timing of cord clamping and oxidative stress in term newborns.

    Science.gov (United States)

    Díaz-Castro, Javier; Florido, Jesus; Kajarabille, Naroa; Garrido-Sánchez, Maria; Padilla, Carmen; de Paco, Catalina; Navarrete, Luis; Ochoa, Julio J

    2014-08-01

    Clamping and cutting of the umbilical cord is the most prevalent of all operations, but the optimal timing of cord clamping is controversial, with different timings offering advantages and disadvantages. This study, for the first time, compares the influence of early and late cord clamping in correlation with oxidative stress and inflammation signaling, Because cord clamping timing may have a significant influence on placenta-to-infant blood transfer, thereby modifying oxygenation of maternal and fetal tissues, and on the transfer of inflammatory mediators throughout the placenta. Sixty-four pregnant subjects were selected at the Gynecology and Obstetrics Services Department of the Clinico San Cecilio Hospital, Granada, Spain, based on disease-free women who experienced a normal course of pregnancy and a spontaneous, vaginal, single delivery. Half of the subjects had deliveries with early-clamped newborn infants (at 10 s), and the other half had late-clamped deliveries (at 2 min). Erythrocyte catalase activity was significantly greater in the late-clamped group than in the early-clamped group (P umbilical vein and P clamped group compared with the early-clamped group (P cord clamping, produced by an increase in antioxidant capacity and moderation of the inflammatory-mediated effects induced during delivery of term neonates. Copyright © 2014 by the American Academy of Pediatrics.

  19. The Power of the Point: Benjamin Franklin, the Lightning Rod and Two Misconceptions That Have Plagued Us to This Day

    Science.gov (United States)

    Aulich, G. D.; Moore, C. B.; Rison, W.

    2006-12-01

    Most people know that Ben Franklin invented the lightning rod and that his rods have successfully protected structures for over 250 years. What people don't know is that he invented them on the basis of two misconceptions. The first, that an elevated pointed conductor would discharge a thunderstorm, thereby preventing lightning. The second, that, should the first process fail, the elevated conductor, by virtue of its pointed tip, would serve as a preferred receptor for any lightning strokes that did occur. It has long been known that grounded, elevated, pointed conductors can not discharge thunderstorms and experiments conducted at the Langmuir Laboratory during the 1990s have shown that moderately blunt, rather than pointed, rods are the best receptors for lightning strokes. Nevertheless, Franklin's incorrect ideas about lightning rods persist in many minds, even among some people in the lightning protection business.

  20. Regulatory perspective on incomplete control rod insertions

    Energy Technology Data Exchange (ETDEWEB)

    Chatterton, M.

    1997-01-01

    The incomplete control rod insertions experienced at South Texas Unit 1 and Wolf Creek are of safety concern to the NRC staff because they represent potential precursors to loss of shutdown margin. Even before it was determined if these events were caused by the control rods or by the fuel there was an apparent correlation of the problem with high burnup fuel. It was determined that there was also a correlation between high burnup and high drag forces as well as with rod drop time histories and lack of rod recoil. The NRC staff initial actions were aimed at getting a perspective on the magnitude of the problem as far as the number of plants and the amount of fuel that could be involved, as well as the safety significance in terms of shutdown margin. As tests have been performed and data has been analyzed the focus has shifted more toward understanding the problem and the ways to eliminate it. At this time the staff`s understanding of the phenomena is that it was a combination of factors including burnup, power history and temperature. The problem appears to be very sensitive to these factors, the interaction of which is not clearly understood. The model developed by Westinghouse provides a possible explanation but there is not sufficient data to establish confidence levels and sensitivity studies involving the key parameters have not been done. While several fixes to the problem have been discussed, no definitive fixes have been proposed. Without complete understanding of the phenomena, or fixes that clearly eliminate the problem the safety concern remains. The safety significance depends on the amount of shutdown margin lost due to incomplete insertion of the control rods. Were the control rods to stick high in the core, the reactor could not be shutdown by the control rods and other means such as emergency boration would be required.

  1. Umbilical cord clamping at birth--practice in Norwegian maternity wards.

    Science.gov (United States)

    Lundberg, Camilla; Øian, Pål; Klingenberg, Claus

    2013-11-26

    The timing and practice used for umbilical cord clamping of neonates are controversial internationally as well as in Norway. We therefore wished to investigate routines and practices for umbilical cord clamping of neonates in Norway. A web-based questionnaire was sent to heads of departments of all maternity wards in Norway (n = 52). They were asked about their practice with regard to umbilical cord clamping of neonates and whether written routines had been prepared for this purpose. We defined early umbilical cord clamping as immediate or within 30 seconds and late clamping as ≥ 1 minute or not until pulsation in the umbilical cord had ceased. Fifty (96%) of the maternity institutions returned a completed questionnaire. Twelve institutions (24%) reported to clamp the umbilical cord of full-term neonates early, and 38 (76%) reported to practise late clamping. Nineteen maternity wards (38%) followed written routines for umbilical cord clamping of full-term neonates, and among these, early umbilical cord clamping was practised in nine (47%). In the 31 maternity wards that had no written routines, early umbilical cord clamping was practised in three (10%). Twenty-seven of the maternity wards reported that the child is placed on the maternal abdomen before clamping of the umbilical cord, 14 reported that the child commonly is held below the introitus before umbilical cord clamping, and the rest did not report any consistent practice. There is wide variation in the practice for umbilical cord clamping in Norwegian maternity wards, many of which have no written guidelines. We argue that national guidelines for umbilical cord clamping of neonates should be established.

  2. Geometric Nonlinear Computation of Thin Rods and Shells

    Science.gov (United States)

    Grinspun, Eitan

    2011-03-01

    We develop simple, fast numerical codes for the dynamics of thin elastic rods and shells, by exploiting the connection between physics, geometry, and computation. By building a discrete mechanical picture from the ground up, mimicking the axioms, structures, and symmetries of the smooth setting, we produce numerical codes that not only are consistent in a classical sense, but also reproduce qualitative, characteristic behavior of a physical system----such as exact preservation of conservation laws----even for very coarse discretizations. As two recent examples, we present discrete computational models of elastic rods and shells, with straightforward extensions to the viscous setting. Even at coarse discretizations, the resulting simulations capture characteristic geometric instabilities. The numerical codes we describe are used in experimental mechanics, cinema, and consumer software products. This is joint work with Miklós Bergou, Basile Audoly, Max Wardetzky, and Etienne Vouga. This research is supported in part by the Sloan Foundation, the NSF, Adobe, Autodesk, Intel, the Walt Disney Company, and Weta Digital.

  3. Bent Telescopic Rods in Patients With Osteogenesis Imperfecta.

    Science.gov (United States)

    Lee, R Jay; Paloski, Michael D; Sponseller, Paul D; Leet, Arabella I

    2016-09-01

    Telescopic rods require alignment of 2 rods to enable lengthening. A telescopic rod converts functionally into a solid rod if either rod bends, preventing proper engagement. Our goal was to characterize implant bending as a mode of failure of telescopic rods used in the treatment of osteogenesis imperfecta in children. We conducted a retrospective review of our osteogenesis imperfecta database for patients treated with intramedullary telescopic rods at our institution from 1992 through 2010 and identified 12 patients with bent rods. The 6 boys and 6 girls had an average age at the time of initial surgery of 3.1 years (range, 1.8 to 8.3 y) and a total of 51 telescoping rods. Clinic notes, operative reports, and radiographs were reviewed. The rods were analyzed for amount of lengthening, characteristics of bending, presence of cut out, or disengagement from an anchor point. Bends in the rods were characterized by their location on the implant component. The bent and straight rods were compared. Data were analyzed with the Mann-Whitney test (statistical significance set at P≤0.05). Of the 51 telescoping rods, 17 constructs (33%) bent. The average interval between surgery and rod bending was 4.0 years (range, 0.9 to 8.2 y). Before bending, 11 of 17 telescoping rods had routine follow-up radiographs for review. In 10 of the rods, bending was present when early signs of rod failure were first detected. Rod bending did not seem to be related to rod size. There was no area on the rod itself that seemed more susceptible to bending. Rod bending can be an early sign of impending rod failure. When rod bending is first noted, it may predispose the rod to other subsequent failures such as loss of proximal and distal fixation and cut out. Rod bending should be viewed as an indicator for closer monitoring of the patient and discussions regarding future need for rod exchange. Level III-retrospective review.

  4. Axial Vibration Confinement in Nonhomogenous Rods

    Directory of Open Access Journals (Sweden)

    S. Choura

    2005-01-01

    Full Text Available A design methodology for the vibration confinement of axial vibrations in nonhomogenous rods is proposed. This is achieved by a proper selection of a set of spatially dependent functions characterizing the rod material and geometric properties. Conditions for selecting such properties are established by constructing positive Lyapunov functions whose derivative with respect to the space variable is negative. It is shown that varying the shape of the rod alone is sufficient to confine the vibratory motion. In such a case, the vibration confinement requires that the eigenfunctions be exponentially decaying functions of space, where the notion of spatial domain stability is introduced as a concept dual to that of the time domain stability. It is also shown that vibration confinement can be produced if the rod density and/or stiffness are varied with respect to the space variable while the cross-section area is kept constant. Several case studies, supporting the developed conditions imposed on the spatially dependent functions for vibration confinement in vibrating rods, are discussed. Because variation in the geometric and material properties might decrease the critical buckling loads, we also discuss the buckling problem.

  5. Wetting of a partially immersed compliant rod

    Science.gov (United States)

    Hui, Chung-Yuen; Jagota, Anand

    2016-11-01

    The force on a solid rod partially immersed in a liquid is commonly used to determine the liquid-vapor surface tension by equating the measured force required to remove the rod from the liquid to the vertical component of the liquid-vapor surface tension. Here, we study how this process is affected when the rod is compliant. For equilibrium, we enforce force and configurational energy balance, including contributions from elastic energy. We show that, in general, the contact angle does not equal that given by Young's equation. If surface stresses are tensile, the strain in the immersed part of the rod is found to be compressive and to depend only on the solid-liquid surface stress. The strain in the dry part of the rod can be either tensile or compressive, depending on a combination of parameters that we identify. We also provide results for compliant plates partially immersed in a liquid under plane strain and plane stress. Our results can be used to extract solid surface stresses from such experiments.

  6. Single Rod Vibration in Axial Flow

    Science.gov (United States)

    Weichselbaum, Noah; Wang, Shengfu; Bardet, Philippe

    2013-11-01

    Fluid structure interaction of a single rod in axial flow is a coupled dynamical system present in many application including nuclear reactors, steam generators, and towed antenna arrays. Fluid-structure response can be quantified thanks to detailed experimental data where both structure and fluid responses are recorded. Such datum deepen understanding of the physics inherent to the system and provide high-dimensionality quantitative measurements to validate coupled structural and CFD codes with various level of complexity. In this work, single rods fixed on both ends in a concentric pipe, are subjected to an axial flow with Reynolds number based on hydraulic diameter of Re =4000. Rods of varying material stiffness and diameter are utilized in the experiment resulting in a range of dimensionless U between 0.5 and 1, where U = (ρA/EI)1/2uL. Experimental measurements of the velocity field around the rod are taken with PIV from time-resolved Nd:YLF laser and a high speed CMOS camera. Three-dimensional and temporal vibration and deflection of the rod is recorded with shadowgraphy utilizing two sets of pulsed high power LED and dedicated CMOS camera. Through integration of these two diagnostics, it is possible to reconstruct the full FSI domain providing unique validation data.

  7. Dielectric rod feed for compact range reflector

    CERN Document Server

    Balabukha, Nikolay P; Shapkina, Natalia E

    2014-01-01

    A dielectric rod feed with a special radiation pattern of a tabletop form used for the compact range reflector is developed and analyzed. Application of this feed increases the size of the compact range quiet zone generated by the reflector. The feed consists of the dielectric rod made of polystyren, the rod is inserted into the circular waveguide with a corrugated flange. The waveguide is excited by the H11-mode. The rod is covered by the textolite biconical bushing and has a fluoroplastic insert in the vicinity of the bushing. Mathematical modeling was used to obtain the parameters of the feed for the optimal tabletop form of the radiation pattern. The problem of the electromagnetic radiation was solved for metal-dielectric bodies of rotation by method of integral equations with further solving of the problem of the synthesis for feed parameters. The dielectric rod feed was fabricated for the X-frequency range. Feed amplitude and phase patterns were measured in the frequency range 8.2-12.5 GHz. Presented re...

  8. Accelerated commutation for passive clamp isolated boost converters

    OpenAIRE

    2002-01-01

    An efficient and cost effective bidirectional DC/DC converter reduces switch voltage stress via accelerated commutation allowing use of a low-cost passive clamp circuit in boost mode. The converter includes a primary circuit, transformer and secondary circuit. The primary circuit takes the form of a “full bridge converter,” a “push-pull converter,” or an “L-type converter.”. The primary circuit may include a dissipator such as a snubber circuit or small buck converter. A secondary side of the...

  9. Potassium Chloride Versus Voltage Clamp Contractures in Ventricular Muscle

    Science.gov (United States)

    Morad, M.; Reeck, S.; Rao, M.

    1981-01-01

    In frog ventricle, developed tension was markedly larger in response to depolarization caused by a voltage clamp step than to depolarization induced by high concentrations of potassium chloride. Measurement of extracellular potassium activity at the surface and at the depth of muscle during the development of contractures showed that the diffusion of potassium is much slower than the spread of depolarization through the cross section of muscle. These two observations suggest that competition between the depolarizing and the negative inotropic effects of an increase in the extracellular potassium ion concentration may determine the time course and magnitude of contractile tension in heart muscle.

  10. Effect of Clamping Rigidity of the Armour on Ballistic Performance

    Directory of Open Access Journals (Sweden)

    S. N. Dikshit

    1992-04-01

    Full Text Available Influence of the manner in which the armour plates are held during their ballistic testing on the armour performance, has been evaluated. One armour plate was clamped rigidly to the test stand while a second plate of identical composition, hardness, and dimensions was hung loosely from the target holder. Both these plates were impacted with the same type of projectiles and over the same impact velocity range. The nature of ballistic damage evaluated indicates that the manner in which the armour is held during ballistic testing has a negligible influence on its performance at least when the mass of the plate is substantially higher than that of the projectile.

  11. Euglycemic clamp insulin sensitivity and longitudinal systolic blood pressure

    DEFF Research Database (Denmark)

    Petrie, John R; Malik, Muhammad Omar; Balkau, Beverley

    2013-01-01

    Insulin resistance may be an independent risk factor for the development of hypertension, but change in blood pressure (BP) over time has not been adequately studied in healthy individuals fully characterized for insulin sensitivity. In the Relationship between Insulin Sensitivity...... and Cardiovascular disease (RISC) study, we measured insulin sensitivity (M/I) using the euglycemic clamp technique in 1073 healthy European adults (587 women, 486 men) aged 30 to 60 years followed up 3 years later. Systolic BP (SBP) at baseline was higher in insulin-resistant women (ie, those in the low sex...

  12. Pulsewidth Modulation of Neutral-Point-Clamped Indirect Matrix Converter

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Poh Chiang, Loh; Gao, Feng

    2008-01-01

    discussed in the existing literature. Addressing the previously described issues, this paper focuses on the operational mode analysis of a three-level indirect matrix converter implemented using a neutral-point-clamped inversion stage and the design of a number of PWM and modulation ratio compensation...... schemes for controlling the converter with improved waveform quality. The performances and practicalities of the designed schemes are verified in simulation and experimentally using an implemented laboratory prototype with some representative results captured and presented in this paper....

  13. Rod consolidation at the West Valley Demonstration Project

    Energy Technology Data Exchange (ETDEWEB)

    Bailey, W.J.

    1986-12-01

    A rod consolidation demonstration with irradiated pressurized water reactor fuel was recently conducted by personnel from Nuclear Assurance Corporation and West Valley Nuclear Services Company at the West Valley Demonstration Project in West Valley, New York. The rod consolidation demonstration involved pulling all of the fuel rods from six fuel Assemblies. In general, the rod pulling proceeded smoothly. The highest compaction ratio attained was 1:8:1. Among the total of 1074 fuel rods were some known degraded rods (they had collapsed cladding, a result of in-reactor fuel densification), but no rods were broken or dropped during the demonstration. One aim was to gather information on the effect of rod consolidation operations on the integrity of the fuel rods during subsequent handling and storage. Another goal was to collect information on the condition and handling of intact, damaged, and failed fuel that has been in storage for an extended period. 9 refs., 8 figs., 1 tab.

  14. Vibrational frequency of a strong-coupling polaron in a quantum rod at finite temperatures

    Institute of Scientific and Technical Information of China (English)

    Ding Zhao-Hua; Xiao Jing-Lin

    2011-01-01

    The Hamiltonian of a quantum rod with a boundary is presented after a coordinate transformation that changes the original ellipsoidal boundary into a spherical one. We then study the effect of temperature on the vibrational frequency and the ground state binding energy of the strong-coupling polaron in the rod. The two quantities are expressed as functions of the aspect ratio of the ellipsoid,the transverse and the longitudinal effective confinement lengths,the temperature and the electron-phonon coupling strength by linear combination operator and unitary transformation methods. It is found that the vibrational frequency and the ground state binding energy will increase rapidly with decreasing transverse and longitudinal effective confinement lengths. They are increasing functions of the electronphonon coupling strength but become decreasing ones of the temperature and the aspect ratio.

  15. Magnetic switch for reactor control rod. [LMFBR

    Science.gov (United States)

    Germer, J.H.

    1982-09-30

    A magnetic reed switch assembly is described for activating an electromagnetic grapple utilized to hold a control rod in position above a reactor core. In normal operation the magnetic field of a permanent magnet is short-circuited by a magnetic shunt, diverting the magnetic field away from the reed switch. The magnetic shunt is made of a material having a Curie-point at the desired release temperature. Above that temperature the material loses its ferromagnetic properties, and the magnetic path is diverted to the reed switch which closes and short-circuits the control circuit for the control rod electro-magnetic grapple which allows the control rod to drop into the reactor core for controlling the reactivity of the core.

  16. Delayed clamping of the umbilical cord after delivery and implications for public cord blood banking.

    Science.gov (United States)

    Allan, David S; Scrivens, Nicholas; Lawless, Tiffany; Mostert, Karen; Oppenheimer, Lawrence; Walker, Mark; Petraszko, Tanya; Elmoazzen, Heidi

    2016-03-01

    Public banking of umbilical cord blood units (CBUs) containing higher numbers of cells ensures timely engraftment after transplantation for increasing numbers of patients. Delayed clamping of the umbilical cord after birth may benefit some infants by preventing iron deficiency. Implications of delayed cord clamping for public cord blood banking remains unclear. CBUs collected by Canadian Blood Services at one collection site between November 1, 2014, and March 17, 2015, were analyzed. The delay in cord clamping after birth was timed and classified as "no delay," 20 to 60 seconds, more than 60 seconds, or more than 120 seconds. Of 367 collections, 100 reported no delay in clamping while clamping was delayed by 20 to 60 seconds (n = 69), more than 60 seconds (n = 98), or more than 120 seconds (n = 100) in the remaining cases. The mean volume and total nucleated cells (TNCs) in units with no delay in clamping were significantly greater than mean volumes for all categories of delayed clamping (Tukey's test, p clamping was delayed (p = 5.5 × 10(-8) ). The difference was most marked for cords that were clamped more than 120 seconds after delivery (6.2% compared with 39%). Delayed cord clamping greatly diminishes the volume and TNC count of units collected for a public cord blood bank. Creating an inventory of CBUs with high TNC content may take more time than expected. © 2015 AABB.

  17. Delayed Umbilical Cord Clamping in the 21st Century: Indications for Practice.

    Science.gov (United States)

    Bayer, Kimberly

    2016-02-01

    Health care providers have debated the timing of umbilical cord clamping since the days of Aristotle. Delayed cord clamping was the mainstay of practice until about the 1950s when it was changed to immediate clamping on the basis of a series of blood volume studies combined with the introduction of active management of the third stage of labor. However, in recent years, several systematic reviews advise that delayed cord clamping should be used in all births for at least 30 to 60 seconds. The purpose of this article is to discuss the physiology of umbilical cord clamping, the potential benefits and adverse effects of delayed cord clamping, and how this affects the advanced practice nurse. A search of PubMed, Cochrane Reviews, and Clinical Key was used to find relevant research on the topic of umbilical cord clamping. Potential benefits of delayed cord clamping include decreased frequency of iron-deficiency anemia in the first year of life with improved neurodevelopmental outcomes in term infants, reduced need for blood transfusions, possible autologous transfusion of stem cells, and a decreased incidence of intraventricular hemorrhage. Apprehension exists regarding the feasibility of the practice as well as the potential hindrance of immediate resuscitation. There is a need to begin to look for populations for which delayed cord clamping can be implemented. Recommendations are inconsistent on the patient population and timing; therefore, further studies are needed to understand the multiple variables that affect timing of umbilical cord clamping.

  18. Randomised trial of cord clamping and initial stabilisation at very preterm birth.

    Science.gov (United States)

    Duley, Lelia; Dorling, Jon; Pushpa-Rajah, Angela; Oddie, Sam J; Yoxall, Charles William; Schoonakker, Bernard; Bradshaw, Lucy; Mitchell, Eleanor J; Fawke, Joe Anthony

    2017-09-18

    For very preterm births, to compare alternative policies for umbilical cord clamping and immediate neonatal care. Parallel group randomised (1:1) trial, using sealed opaque numbered envelopes. Eight UK tertiary maternity units. 261 women expected to have a live birth before 32 weeks, and their 276 babies. Cord clamping after at least 2 min and immediate neonatal care with cord intact, or clamping within 20 s and immediate neonatal care after clamping. Intraventricular haemorrhage (IVH), death before discharge. 132 women (137 babies) were allocated clamping ≥2 min and neonatal care cord intact, and 129 (139) clamping ≤20 s and neonatal care after clamping; six mother-infant dyads were excluded (2, 4) as birth was after 35(+6) weeks, one withdrew (death data only available) (0, 1). Median gestation was 28.9 weeks for those allocated clamping ≥2 min, and 29.2 for those allocated clamping ≤20 s. Median time to clamping was 120 and 11 s, respectively. 7 of 135 infants (5.2%) allocated clamping ≥2 min died and 15 of 135 (11.1%) allocated clamping ≤20 s; risk difference (RD) -5.9% (95% CI -12.4% to 0.6%). Of live births, 43 of 134 (32%) had IVH vs 47 of 132 (36%), respectively; RD -3.5% (-14.9% to 7.8%). There were no clear differences in other outcomes for infants or mothers. This is promising evidence that clamping after at least 2 min and immediate neonatal care with cord intact at very preterm birth may improve outcome; a large trial is urgently needed. ISRCTN 21456601. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  19. Patch-clamp detection of macromolecular translocation along nuclear pores

    Directory of Open Access Journals (Sweden)

    Bustamante J.O.

    1998-01-01

    Full Text Available The present paper reviews the application of patch-clamp principles to the detection and measurement of macromolecular translocation along the nuclear pores. We demonstrate that the tight-seal 'gigaseal' between the pipette tip and the nuclear membrane is possible in the presence of fully operational nuclear pores. We show that the ability to form a gigaseal in nucleus-attached configurations does not mean that only the activity of channels from the outer membrane of the nuclear envelope can be detected. Instead, we show that, in the presence of fully operational nuclear pores, it is likely that the large-conductance ion channel activity recorded derives from the nuclear pores. We conclude the technical section with the suggestion that the best way to demonstrate that the nuclear pores are responsible for ion channel activity is by showing with fluorescence microscopy the nuclear translocation of ions and small molecules and the exclusion of the same from the cisterna enclosed by the two membranes of the envelope. Since transcription factors and mRNAs, two major groups of nuclear macromolecules, use nuclear pores to enter and exit the nucleus and play essential roles in the control of gene activity and expression, this review should be useful to cell and molecular biologists interested in understanding how patch-clamp can be used to quantitate the translocation of such macromolecules into and out of the nucleus

  20. HIGH STRENGTH CONTROL RODS FOR NEUTRONIC REACTORS

    Science.gov (United States)

    Lustman, B.; Losco, E.F.; Cohen, I.

    1961-07-11

    Nuclear reactor control rods comprised of highly compressed and sintered finely divided metal alloy panticles and fine metal oxide panticles substantially uniformly distributed theretbrough are described. The metal alloy consists essentially of silver, indium, cadmium, tin, and aluminum, the amount of each being present in centain percentages by weight. The oxide particles are metal oxides of the metal alloy composition, the amount of oxygen being present in certain percentages by weight and all the oxygen present being substantially in the form of metal oxide. This control rod is characterized by its high strength and resistance to creep at elevated temperatures.

  1. Sensitivity study of control rod depletion coefficients

    OpenAIRE

    Blomberg, Joel

    2015-01-01

    This report investigates the sensitivity of the control rod depletion coefficients, Sg, to different input parameters and how this affects the accumulated 10B depletion, β. Currently the coefficients are generated with PHOENIX4, but the geometries can be more accurately simulated in McScram. McScram is used to calculate Control Rod Worth, which in turn is used to calculate Nuclear End Of Life, and Sg cannot be generated in the current version of McScram. Therefore, it is also analyzed whether...

  2. Quivers For Special Fuel Rods-Disposal Of Special Fuel Rods In CASTOR V Casks

    Energy Technology Data Exchange (ETDEWEB)

    Bannani, Amin; Cebula, Wojciech; Buchmuller, Olga; Huggenberg, Roland [GNS, Essen (Germany); Helmut Kuhl [WTI, Julich (Germany)

    2015-05-15

    While GNS casks of the CASTOR family are a suitable means to transfer fuel assemblies (FA) from the NPP to an interim dry storage site, Germanys phase-out of nuclear energy has triggered the demand for an additional solution to dispose of special fuel rods (SFR), normally remaining in the fuel pond until the final shutdown of the NPP. SFR are fuel rods that had to be removed from fuel assemblies mainly due to their special condition, e. g. damages in the cladding of the fuel rods which may have occurred during reactor operations. SFR are usually stored in the spent fuel pond after they are removed from the FA. The quiver for special fuel rods features a robust yet simple design, with a high mechanical stability, a reliable leak-tightness and large safety margins for future requirements on safety analysis. The quiver for special fuel rods can be easily adapted to a large variety of different damaged fuel rods and tailored to the specific need of the customer. The quiver for special fuel rods is adaptable e.g. in length and diameter for use in other types of transport and storage casks and is applicable in other countries as well. The overall concept presented here is a first of its kind solution for the disposal of SFRs via Castor V-casks. This provides an important precondition in achieving the status 'free from nuclear fuel' of the shut down German NPPs.

  3. Pulsed positive discharges in air at moderate pressures near a dielectric rod

    Science.gov (United States)

    Dubinova, A.; Trienekens, D.; Ebert, U.; Nijdam, S.; Christen, T.

    2016-10-01

    We study pulsed positive discharges in air in a cylindrically symmetric setup with an electrode needle close (about 1 mm) above the top of a dielectric cylindrical rod of 4 mm in diameter mounted at its bottom on a grounded plate electrode. We present ICCD (intensified charge-coupled device) pictures and evaluations of experiments as well as simulations with a fluid discharge model; the simulations use cylindrical symmetry. In the experiments, there is an initial inception cloud phase, where the cylindrical symmetry is maintained, and later a streamer phase, where it is broken spontaneously. At 75-150 mbar, discharges with cylindrical symmetry are not attracted to the dielectric rod, but move away from it. The dielectric rod plays the sole role of an obstacle that shades (in the context of photoionization) a cone-shaped part of the inception cloud; the cone size is determined by the geometry of the setup. The material properties of the dielectric rod, such as its dielectric permittivity and the efficiency of the photon induced secondary electron emission do not have a noticeable effect. This is due to the abundance of photoionization in air, which supplies a positive discharge with free electrons and allows it to propagate along the electric field lines. Using some simple field calculations, we show that field enhancement due to dielectric polarization does not play a significant role in our geometry as long as the discharge maintains its cylindrical symmetry. The field component towards the rod is insufficiently enhanced to cause the discharge to move towards the rod. Any additional electrons produced by the dielectric surface do not influence this discharge morphology. This interpretation is supported by both experiments and simulations. At higher pressures (400-600 mbar) or for larger gaps between the needle and the dielectric rod, the inception cloud reaches its maximal radius within the gap between needle and rod and destabilizes there. In those cases

  4. Modeling and simulation performance of sucker rod beam pump

    Science.gov (United States)

    Aditsania, Annisa; Rahmawati, Silvy Dewi; Sukarno, Pudjo; Soewono, Edy

    2015-09-01

    Artificial lift is a mechanism to lift hydrocarbon, generally petroleum, from a well to surface. This is used in the case that the natural pressure from the reservoir has significantly decreased. Sucker rod beam pumping is a method of artificial lift. Sucker rod beam pump is modeled in this research as a function of geometry of the surface part, the size of sucker rod string, and fluid properties. Besides its length, sucker rod string also classified into tapered and un-tapered. At the beginning of this research, for easy modeling, the sucker rod string was assumed as un-tapered. The assumption proved non-realistic to use. Therefore, the tapered sucker rod string modeling needs building. The numerical solution of this sucker rod beam pump model is computed using finite difference method. The numerical result shows that the peak of polished rod load for sucker rod beam pump unit C-456-D-256-120, for non-tapered sucker rod string is 38504.2 lb, while for tapered rod string is 25723.3 lb. For that reason, to avoid the sucker rod string breaks due to the overload, the use of tapered sucker rod beam string is suggested in this research.

  5. Modeling and simulation performance of sucker rod beam pump

    Energy Technology Data Exchange (ETDEWEB)

    Aditsania, Annisa, E-mail: annisaaditsania@gmail.com [Department of Computational Sciences, Institut Teknologi Bandung (Indonesia); Rahmawati, Silvy Dewi, E-mail: silvyarahmawati@gmail.com; Sukarno, Pudjo, E-mail: psukarno@gmail.com [Department of Petroleum Engineering, Institut Teknologi Bandung (Indonesia); Soewono, Edy, E-mail: esoewono@math.itb.ac.id [Department of Mathematics, Institut Teknologi Bandung (Indonesia)

    2015-09-30

    Artificial lift is a mechanism to lift hydrocarbon, generally petroleum, from a well to surface. This is used in the case that the natural pressure from the reservoir has significantly decreased. Sucker rod beam pumping is a method of artificial lift. Sucker rod beam pump is modeled in this research as a function of geometry of the surface part, the size of sucker rod string, and fluid properties. Besides its length, sucker rod string also classified into tapered and un-tapered. At the beginning of this research, for easy modeling, the sucker rod string was assumed as un-tapered. The assumption proved non-realistic to use. Therefore, the tapered sucker rod string modeling needs building. The numerical solution of this sucker rod beam pump model is computed using finite difference method. The numerical result shows that the peak of polished rod load for sucker rod beam pump unit C-456-D-256-120, for non-tapered sucker rod string is 38504.2 lb, while for tapered rod string is 25723.3 lb. For that reason, to avoid the sucker rod string breaks due to the overload, the use of tapered sucker rod beam string is suggested in this research.

  6. Optimal timing of umbilical cord clamping for term and preterm babies.

    Science.gov (United States)

    Duley, Lelia; Batey, Natalie

    2013-11-01

    Deferring cord clamping allows blood flow between baby and placenta to continue for a few moments. This often leads to increased neonatal blood volume at birth. It also allows for longer transition to the neonatal circulation. Optimal timing for clamping the cord remains uncertain. This paper discusses the physiology of placental transfusion and presents the evidence from systematic reviews of randomised trials comparing alternative strategies for cord clamping for both term and preterm births. For healthy term infants, deferring cord clamping increases iron stores in infancy. Therefore, a more liberal approach to deferring cord clamping appears to be warranted, provided screening and treatment for jaundice requiring phototherapy is available. For preterm births, although there are few data on the main clinical outcomes, the evidence is promising that deferred cord clamping may be beneficial. For both term and preterm infants there is little information about long term development. © 2013.

  7. Solitary waves on nonlinear elastic rods. I

    DEFF Research Database (Denmark)

    Sørensen, Mads Peter; Christiansen, Peter Leth; Lomdahl, P. S.

    1984-01-01

    Acoustic waves on elastic rods with circular cross section are governed by improved Boussinesq equations when transverse motion and nonlinearity in the elastic medium are taken into account. Solitary wave solutions to these equations have been found. The present paper treats the interaction between...

  8. ELECTRIC FIELD MEASUREMENT IN ROD-DISCONTINUED ...

    African Journals Online (AJOL)

    2014-06-30

    Jun 30, 2014 ... The used arrangement with homogeneous system is made up of a square metallic sheet ... This distance is considered positive when the rod is located ... in the case of the discontinuous earth which were defined according to ...

  9. Fabrication of preliminary fuel rods for SFR

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sun Ki; Oh, Seok Jin; Ko, Young Mo; Woo, Youn Myung; Kim, Ki Hwan [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2012-05-15

    Metal fuels was selected for fueling many of the first reactors in the US, including the Experimental Breeder Reactor-I (EBR-I) and the Experimental Breeder Reactor-II (EBR-II) in Idaho, the FERMI-I reactor, and the Dounreay Fast Reactor (DFR) in the UK. Metallic U.Pu.Zr alloys were the reference fuel for the US Integral Fast Reactor (IFR) program. Metallic fuel has advantages such as simple fabrication procedures, good neutron economy, high thermal conductivity, excellent compatibility with a Na coolant and inherent passive safety. U-Zr-Pu alloy fuels have been used for SFR (sodium-cooled fast reactor) related to the closed fuel cycle for managing minor actinides and reducing a high radioactivity levels since the 1980s. Fabrication technology of metallic fuel for SFR has been in development in Korea as a national nuclear R and D program since 2007. For the final goal of SFR fuel rod fabrication with good performance, recently, three preliminary fuel rods were fabricated. In this paper, the preliminary fuel rods were fabricated, and then the inspection for QC(quality control) of the fuel rods was performed

  10. Brownian rod scheme in microenvironment sensing

    Directory of Open Access Journals (Sweden)

    Ian Gralinski

    2012-03-01

    Full Text Available Fluctuations of freely translating spherical particles via Brownian motion should provide inexhaustible information about the micro-environment, but is beset by the problem of particles drifting away from the venue of measurement as well as colliding with other particles. We propose a scheme here to circumvent this in which a Brownian rod that lies in proximity to a cylindrical pillar is drawn in by a tuneable attractive force from the pillar. The force is assumed to act through the centre of each body and the motion exclusive to the x-y plane. Simulation studies show two distinct states, one in which the rod is moving freely (state I and the other in which the rod contacts the cylinder surface (state II. Information about the micro-environment could be obtained by tracking the rotational diffusion coefficient Dθ populating in either of these two states. However, the magnitude of the normalized charge product in excess of 6.3x104 was found necessary for a rod of 6.81 × 0.93 μm2 (length × diameter and 10μm diameter cylindrical pillar to minimize deviation errors. It was also found that the extent of spatial sensing coverage could be controlled by varying the charge level. The conditions needed to ascertain the rotational sampling for angle determination through the Hough transform were also discussed.

  11. Piston rod seal for a Stirling engine

    Science.gov (United States)

    Shapiro, Wilbur

    1984-01-01

    In a piston rod seal for a Stirling engine, a hydrostatic bearing and differential pressure regulating valve are utilized to provide for a low pressure differential across a rubbing seal between the hydrogen and oil so as to reduce wear on the seal.

  12. Adjustable solitary waves in electroactive rods

    Science.gov (United States)

    Wang, Y. Z.; Zhang, C. L.; Dai, H.-H.; Chen, W. Q.

    2015-10-01

    This paper presents an asymptotic analysis of solitary waves propagating in an incompressible isotropic electroactive circular rod subjected to a biasing longitudinal electric displacement. Several asymptotic expansions are introduced to simplify the rod governing equations. The boundary conditions on the lateral surface of the rod are satisfied from the asymptotic point of view. In the limit of finite-small amplitude and long wavelength, a set of ten simplified one-dimensional nonlinear governing equations is established. To validate our approach and the derivation, we compare the linear dispersion relation with the one directly derived from the three-dimensional linear theory in the limit of long wavelength. Then, by the reductive perturbation method, we deduce the far-field equation (i.e. the KdV equation). Finally, the leading order of the electroelastic solitary wave solution is presented. Numerical examples are provided to show the influences of the biasing electric displacement and material constants on the solitary waves. It is found that the biasing electric displacement can modulate the velocity of solitary waves with a prescribed amplitude in the electroactive rod, a very interesting result which may promote the particular application of solitary waves in solids with multi-field coupling.

  13. On contact numbers in random rod packings

    NARCIS (Netherlands)

    Wouterse, A.; Luding, Stefan; Philipse, A.P.

    2009-01-01

    Random packings of non-spherical granular particles are simulated by combining mechanical contraction and molecular dynamics, to determine contact numbers as a function of density. Particle shapes are varied from spheres to thin rods. The observed contact numbers (and packing densities) agree well

  14. Application of Numerical Simulation for the Verification of Design of Clamping a Workpiece in Jaws

    Science.gov (United States)

    Oravcová, Jarmila; Riečičiarová, Eva

    2016-12-01

    This paper deals with the use of the numerical computer oriented method for the analysis and verification of the design of workpiece clamping. The inaccuracies of the positioning in clamping locating points were simulated using the FEM software ANSYS. The influence of inaccuracies in the positions of contact locating points on the displacements of the workpiece characteristic points and their position in clamped removable jaws was examined. The reaction forces in the contact locating points were also computed and analyzed.

  15. Delaying cord clamping until ventilation onset improves cardiovascular function at birth in preterm lambs.

    Science.gov (United States)

    Bhatt, Sasmira; Alison, Beth J; Wallace, Euan M; Crossley, Kelly J; Gill, Andrew W; Kluckow, Martin; te Pas, Arjan B; Morley, Colin J; Polglase, Graeme R; Hooper, Stuart B

    2013-04-15

    Delayed cord clamping improves circulatory stability in preterm infants at birth, but the underlying physiology is unclear. We investigated the effects of umbilical cord clamping, before and after ventilation onset, on cardiovascular function at birth. Prenatal surgery was performed on lambs (123 days) to implant catheters into the pulmonary and carotid arteries and probes to measure pulmonary (PBF), carotid (CaBF) and ductus arteriosus blood flows. Lambs were delivered at 126 ± 1 days and: (1) the umbilical cord was clamped at delivery and ventilation was delayed for about 2 min (Clamp 1st; n = 6), and (2) umbilical cord clamping was delayed for 3-4 min, until after ventilation was established (Vent 1st; n = 6). All lambs were subsequently ventilated for 30 min. In Clamp 1st lambs, cord clamping rapidly (within four heartbeats), but transiently, increased pulmonary and carotid arterial pressures (by ∼30%) and CaBF (from 30.2 ± 5.6 to 40.1 ± 4.6 ml min(-1) kg(-1)), which then decreased again within 30-60 s. Following ventilation onset, these parameters rapidly increased again. In Clamp 1st lambs, cord clamping reduced heart rate (by ∼40%) and right ventricular output (RVO; from 114.6 ± 14.4 to 38.8 ± 9.7 ml min(-1) kg(-1)), which were restored by ventilation. In Vent 1st lambs, cord clamping reduced RVO from 153.5 ± 3.8 to 119.2 ± 10.6 ml min(-1) kg(-1), did not affect heart rates and resulted in stable blood flows and pressures during transition. Delaying cord clamping for 3-4 min until after ventilation is established improves cardiovascular function by increasing pulmonary blood flow before the cord is clamped. As a result, cardiac output remains stable, leading to a smoother cardiovascular transition throughout the early newborn period.

  16. Delaying cord clamping until ventilation onset improves cardiovascular function at birth in preterm lambs

    Science.gov (United States)

    Bhatt, Sasmira; Alison, Beth J; Wallace, Euan M; Crossley, Kelly J; Gill, Andrew W; Kluckow, Martin; te Pas, Arjan B; Morley, Colin J; Polglase, Graeme R; Hooper, Stuart B

    2013-01-01

    Delayed cord clamping improves circulatory stability in preterm infants at birth, but the underlying physiology is unclear. We investigated the effects of umbilical cord clamping, before and after ventilation onset, on cardiovascular function at birth. Prenatal surgery was performed on lambs (123 days) to implant catheters into the pulmonary and carotid arteries and probes to measure pulmonary (PBF), carotid (CaBF) and ductus arteriosus blood flows. Lambs were delivered at 126 ± 1 days and: (1) the umbilical cord was clamped at delivery and ventilation was delayed for about 2 min (Clamp 1st; n = 6), and (2) umbilical cord clamping was delayed for 3–4 min, until after ventilation was established (Vent 1st; n = 6). All lambs were subsequently ventilated for 30 min. In Clamp 1st lambs, cord clamping rapidly (within four heartbeats), but transiently, increased pulmonary and carotid arterial pressures (by ∼30%) and CaBF (from 30.2 ± 5.6 to 40.1 ± 4.6 ml min−1 kg−1), which then decreased again within 30–60 s. Following ventilation onset, these parameters rapidly increased again. In Clamp 1st lambs, cord clamping reduced heart rate (by ∼40%) and right ventricular output (RVO; from 114.6 ± 14.4 to 38.8 ± 9.7 ml min−1 kg−1), which were restored by ventilation. In Vent 1st lambs, cord clamping reduced RVO from 153.5 ± 3.8 to 119.2 ± 10.6 ml min−1 kg−1, did not affect heart rates and resulted in stable blood flows and pressures during transition. Delaying cord clamping for 3–4 min until after ventilation is established improves cardiovascular function by increasing pulmonary blood flow before the cord is clamped. As a result, cardiac output remains stable, leading to a smoother cardiovascular transition throughout the early newborn period. PMID:23401615

  17. Stimulus-evoked outer segment changes in rod photoreceptors

    Science.gov (United States)

    Zhao, Xiaohui; Thapa, Damber; Wang, Benquan; Lu, Yiming; Gai, Shaoyan; Yao, Xincheng

    2016-06-01

    Rod-dominated transient retinal phototropism (TRP) has been recently observed in freshly isolated mouse and frog retinas. Comparative confocal microscopy and optical coherence tomography revealed that the TRP was predominantly elicited from the rod outer segment (OS). However, the biophysical mechanism of rod OS dynamics is still unknown. Mouse and frog retinal slices, which displayed a cross-section of retinal photoreceptors and other functional layers, were used to test the effect of light stimulation on rod OSs. Time-lapse microscopy revealed stimulus-evoked conformational changes of rod OSs. In the center of the stimulated region, the length of the rod OS shrunk, while in the peripheral region, the rod OS swung toward the center region. Our experimental observation and theoretical analysis suggest that the TRP may reflect unbalanced rod disc-shape changes due to localized visible light stimulation.

  18. Validation Test of CARR Safety Rod Driving Mechanism

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    <正>CARR safety Rods are driven by hydraulic force. The safety rod driving mechanism is designed by Tsinghua University and manufactured by Shenyang LIMING factory. Two sets of the mechanism are used for the validation test.

  19. Longitudinal Vibrations of Rheological Rod With Variable Cross Section

    Institute of Scientific and Technical Information of China (English)

    Katica(Stevanovic)HEDRIH; AleksandarFILIPOVSKI

    1999-01-01

    Longitudinal vibrations of rheological rod with variable cross section are examined.Particular solutions and eigenfunction are accomplished for natural vibrations of the rod with hereditary material of standard hereditary body.Some examples are given.

  20. Computer simulation of rod-sphere mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Antypov, Dmytro

    2003-07-01

    Results are presented from a series of simulations undertaken to investigate the effect of adding small spherical particles to a fluid of rods which would otherwise represent a liquid crystalline (LC) substance. Firstly, a bulk mixture of Hard Gaussian Overlap particles with an aspect ratio of 3:1 and hard spheres with diameters equal to the breadth of the rods is simulated at various sphere concentrations. Both mixing-demixing and isotropic-nematic transition are studied using Monte Carlo techniques. Secondly, the effect of adding Lennard-Jones particles to an LC system modelled using the well established Gay-Berne potential is investigated. These rod-sphere mixtures are simulated using both the original set of interaction parameters and a modified version of the rod-sphere potential proposed in this work. The subject of interest is the internal structure of the binary mixture and its dependence on density, temperature, concentration and various parameters characterising the intermolecular interactions. Both the mixing-demixing behaviour and the transitions between the isotropic and any LC phases have been studied for four systems which differ in the interaction potential between unlike particles. A range of contrasting microphase separated structures including bicontinuous, cubic, and micelle-like arrangement have been observed in bulk. Thirdly, the four types of mixtures previously studied in bulk are subjected to a static magnetic field. A variety of novel phases are observed for the cases of positive and negative anisotropy in the magnetic susceptibility. These include a lamellar structure, in which layers of rods are separated by layers of spheres, and a configuration with a self-assembling hexagonal array of spheres. Finally, two new models are presented to study liquid crystal mixtures in the presence of curved substrates. These are implemented for the cases of convex and concave spherical surfaces. The simulation results obtained in these geometries

  1. Diuretic response to acute hypertension is blunted during angiotensin II clamp

    DEFF Research Database (Denmark)

    Leong, Patrick K K; Zhang, Yibin; Yang, Li E;

    2002-01-01

    ("ANG II clamp"). When blood pressure was acutely increased 50-60 mmHg by arterial constriction without ANG II clamp, urine output and endogenous lithium clearance increased 4.0- and 6.7-fold, respectively. With ANG II clamp, the effects of acute hypertension were reduced 50%: urine output...... and endogenous lithium clearance increased two- and threefold, respectively. We conclude that HOE-140, an inhibitor of the B(2) receptor, potentiates the sensitivity of arterial pressure to ANG II and that clamping systemic ANG II levels during acute hypertension blunts the magnitude of the pressure diuretic...

  2. Modeling of SVM Diode Clamping Three-Level Inverter Connected to Grid

    DEFF Research Database (Denmark)

    Guo, Yougui; Zeng, Ping; Zhu, Jieqiong

    2011-01-01

    PLECS is used to model the diode clamping three-level inverter connected to grid and good results are obtained. First the output voltage SVM is described for diode clamping three-level inverter with loads connected to Y. Then the output voltage SVM of diode clamping three-level inverter is simply...... is very powerful tool to real power circuits and it is very easy to simulate them. They have also verified that SVM control strategy is feasible to control the diode clamping three-level inverter....

  3. Electrically integrated SU-8 clamped graphene drum resonators for strain engineering

    Science.gov (United States)

    Lee, Sunwoo; Chen, Changyao; Deshpande, Vikram V.; Lee, Gwan-Hyoung; Lee, Ilkyu; Lekas, Michael; Gondarenko, Alexander; Yu, Young-Jun; Shepard, Kenneth; Kim, Philip; Hone, James

    2013-04-01

    Graphene mechanical resonators are the ultimate two-dimensional nanoelectromechanical systems (NEMS) with applications in sensing and signal processing. While initial devices have shown promising results, an ideal graphene NEMS resonator should be strain engineered, clamped at the edge without trapping gas underneath, and electrically integratable. In this Letter, we demonstrate fabrication and direct electrical measurement of circular SU-8 polymer-clamped chemical vapor deposition graphene drum resonators. The clamping increases device yield and responsivity, while providing a cleaner resonance spectrum from eliminated edge modes. Furthermore, the clamping induces a large strain in the resonator, increasing its resonant frequency.

  4. COMPARISON OF EARLY AND DELAYED UMBILICAL CORD CLAMPING IN THE THIRD STAGE OF LABOUR

    Directory of Open Access Journals (Sweden)

    Tamara Serdinšek

    2015-09-01

    Full Text Available Background: Umbilical cord clamping in the third stage of labour is still controversial. Early cord clamping is defined as clamping at 10, 15, 30 or 60 seconds after delivery and delayed as clamping after 60 seconds or at 2-5 minutes after delivery, when the cord stops pulsating or when the placenta is visible within the birth canal. Early clamping is one of the three components of active management of the third stage of labour, which has been used widely in modern obstetrics during the last century. However, in some northern European countries, various parts of the USA and Canada and in developing countries physiological management is preferred.Conclusions: After publication of several trials describing advantages of delayed clamping, this has recently been progressively replacing early clamping. The most important advantages of delayed cord clamping are higher haemoglobin and ferritin levels, higher iron stores, lower incidence of iron deficiency anaemia, better cardiopulmonary adaptation, lower rate of respiratory distress syndrome, and longer duration of early breastfeeding in term neonates, while there is no increase in the incidence of postpartum haemorrhage. Delayed clamping seems to bring some advantages for preterm neonates as well. However, caution is still advised because of the potential adverse effects, especially polycythaemia with hyperviscosity, hyperbilirubinaemia and respiratory distress.

  5. Beliefs and practices of obstetric care providers regarding umbilical cord clamping.

    Science.gov (United States)

    Hill, Allyson L; Fontenot, Holly B

    2014-01-01

    The optimal timing for umbilical cord clamping after birth has yet to be established, and controversy exists. There is evidence of potentially significant health benefits of delayed cord clamping for both full-term and preterm newborns, but this practice has not been widely adopted. This column takes a second look at two recent studies in which researchers examined the beliefs and practices of obstetric care providers regarding umbilical cord clamping in North America. Nurses who are aware of the latest science and who understand both existing practice patterns as well as practice barriers to delayed clamping can be leaders in and advocates for change. © 2014 AWHONN.

  6. Cryogenic Clamp-on Ultrasonic Flowmeters using Single Crystal Piezoelectric Transducers Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Clamp-on ultrasound cryogenic flowmeters using single crystal piezoelectric transducers are proposed to enable reliable, accurate cryogenic instrumentation needs in...

  7. Mechanism of ATP-driven PCNA clamp loading by S. cerevisiae RFC.

    Science.gov (United States)

    Chen, Siying; Levin, Mikhail K; Sakato, Miho; Zhou, Yayan; Hingorani, Manju M

    2009-05-08

    Circular clamps tether polymerases to DNA, serving as essential processivity factors in genome replication, and function in other critical cellular processes as well. Clamp loaders catalyze clamp assembly onto DNA, and the question of how these proteins construct a topological link between a clamp and DNA, especially the mechanism by which ATP is utilized for the task, remains open. Here we describe pre-steady-state analysis of ATP hydrolysis, proliferating cell nuclear antigen (PCNA) clamp opening, and DNA binding by Saccharomyces cerevisiae replication factor C (RFC), and present the first kinetic model of a eukaryotic clamp-loading reaction validated by global data analysis. ATP binding to multiple RFC subunits initiates a slow conformational change in the clamp loader, enabling it to bind and open PCNA and to bind DNA as well. PCNA opening locks RFC into an active state, and the resulting RFC.ATP.PCNA((open)) intermediate is ready for the entry of DNA into the clamp. DNA binding commits RFC to ATP hydrolysis, which is followed by PCNA closure and PCNA.DNA release. This model enables quantitative understanding of the multistep mechanism of a eukaryotic clamp loader and furthermore facilitates comparative analysis of loaders from diverse organisms.

  8. Grounded theory.

    Science.gov (United States)

    Harris, Tina

    2015-04-29

    Grounded theory is a popular research approach in health care and the social sciences. This article provides a description of grounded theory methodology and its key components, using examples from published studies to demonstrate practical application. It aims to demystify grounded theory for novice nurse researchers, by explaining what it is, when to use it, why they would want to use it and how to use it. It should enable nurse researchers to decide if grounded theory is an appropriate approach for their research, and to determine the quality of any grounded theory research they read.

  9. Electrothermally actuated tunable clamped-guided resonant microbeams

    KAUST Repository

    Alcheikh, Nouha

    2017-06-11

    We present simulation and experimental investigation demonstrating active alteration of the resonant and frequency response behavior of resonators by controlling the electrothermal actuation method on their anchors. In-plane clamped-guided arch and straight microbeams resonators are designed and fabricated with V-shaped electrothermal actuators on their anchors. These anchors not only offer various electrothermal actuation options, but also serve as various mechanical stiffness elements that affect the operating resonance frequency of the structures. We have shown that for an arch, the first mode resonance frequency can be increased up to 50% of its initial value. For a straight beam, we have shown that before buckling, the resonance frequency decreases to very low values and after buckling, it increases up to twice of its initial value. These results can be promising for the realization of different wide–range tunable microresonator. The experimental results have been compared to multi-physics finite-element simulations showing good agreement among them.

  10. Trans-Z-source Neutral Point Clamped inverter

    DEFF Research Database (Denmark)

    Mo, W.; Loh, P. C.; Li, D.;

    2012-01-01

    Transformer based Z-source (trans-Z-source) inverters are recently proposed by extending the traditional Z-source inverter with higher buck-boost capability as well as reducing the passive components at the same time. Multi-Level Z-source inverters are single-stage topological solutions used...... modulation scheme, the three-level trans-Z-source inverter can function with minimum of six device commutations per half carrier cycle (same as the traditional buck NPC inverter), while maintaining to produce the designed volt-sec average and inductive voltage boosting at ac output terminals. The designed...... for buck-boost energy conversion with all the favourable advantages of multi-level switching retained. This paper presents three-level trans-Z-source Neutral Point Clamped (NPC) inverter topology, which achieves both the advantages of trans-Z-source and three-level NPC inverter configuration. With proper...

  11. Control rod reactivity measurement by rod-drop method at a fast critical assembly

    Energy Technology Data Exchange (ETDEWEB)

    Song, L.; Yin, Y.; Lian, X.; Zheng, C. [Inst. of Nuclear Physics and Chemistry in CAEP, P. O. Box 919 210, Mianyang, Sichuan, 621900 (China)

    2012-07-01

    Rod-drop experiments were carried out to estimate the reactivity of the control rod of a fast critical assembly operated by CAEP. Two power monitor systems were used to obtain the power level and integration method was used to process the data. Three experiments were performed. The experimental results of the reactivity from the two power monitor systems were consistent and showed a reasonable range of reactivity compared to results from positive period method. (authors)

  12. The timing of umbilical cord clamping at birth: physiological considerations.

    Science.gov (United States)

    Hooper, Stuart B; Binder-Heschl, Corinna; Polglase, Graeme R; Gill, Andrew W; Kluckow, Martin; Wallace, Euan M; Blank, Douglas; Te Pas, Arjan B

    2016-01-01

    While it is now recognized that umbilical cord clamping (UCC) at birth is not necessarily an innocuous act, there is still much confusion concerning the potential benefits and harms of this common procedure. It is most commonly assumed that delaying UCC will automatically result in a time-dependent net placental-to-infant blood transfusion, irrespective of the infant's physiological state. Whether or not this occurs, will likely depend on the infant's physiological state and not on the amount of time that has elapsed between birth and umbilical cord clamping (UCC). However, we believe that this is an overly simplistic view of what can occur during delayed UCC and ignores the benefits associated with maintaining the infant's venous return and cardiac output during transition. Recent experimental evidence and observations in humans have provided compelling evidence to demonstrate that time is not a major factor influencing placental-to-infant blood transfusion after birth. Indeed, there are many factors that influence blood flow in the umbilical vessels after birth, which depending on the dominating factors could potentially result in infant-to-placental blood transfusion. The most dominant factors that influence umbilical artery and venous blood flows after birth are lung aeration, spontaneous inspirations, crying and uterine contractions. It is still not entirely clear whether gravity differentially alters umbilical artery and venous flows, although the available data suggests that its influence, if present, is minimal. While there is much support for delaying UCC at birth, much of the debate has focused on a time-based approach, which we believe is misguided. While a time-based approach is much easier and convenient for the caregiver, ignoring the infant's physiology during delayed UCC can potentially be counter-productive for the infant.

  13. Dependence of control rod worth on fuel burnup

    Energy Technology Data Exchange (ETDEWEB)

    Savva, P., E-mail: savvapan@ipta.demokritos.g [NCSR ' DEMOKRITOS' , PoB 60228, 15310 Aghia Paraskevi (Greece); Varvayanni, M., E-mail: melina@ipta.demokritos.g [NCSR ' DEMOKRITOS' , PoB 60228, 15310 Aghia Paraskevi (Greece); Catsaros, N., E-mail: nicos@ipta.demokritos.g [NCSR ' DEMOKRITOS' , PoB 60228, 15310 Aghia Paraskevi (Greece)

    2011-02-15

    Research highlights: Diffusion and MC calculations for rod worth dependence on burnup and Xe in reactors. One-step rod withdrawal/insertion are used for rod worth estimation. The study showed that when Xe is present the rods worth is significantly reduced. Rod worth variation with burnup depends on rod position in core. Rod worth obtained with MC code is higher than that obtained from deterministic. - Abstract: One important parameter in the design and the analysis of a nuclear reactor core is the reactivity worth of the control rods, i.e. their efficiency to absorb excess reactivity. The control rod worth is affected by parameters such as the fuel burnup in the rod vicinity, the Xe concentration in the core, the operational time of the rod and its position in the core. In the present work, two different computational approaches, a deterministic and a stochastic one, were used for the determination of the rods worth dependence on the fuel burnup level and the Xe concentration level in a conceptual, symmetric reactor core, based on the MTR fuel assemblies used in the Greek Research Reactor (GRR-1). For the deterministic approach the neutronics code system composed by the SCALE modules NITAWL and XSDRN and the diffusion code CITATION was used, while for the stochastic one the Monte Carlo code TRIPOLI was applied. The study showed that when Xe is present in the core, the rods worth is significantly reduced, while the rod worth variation with increasing burnup depends on the rods position in the core grid. The rod worth obtained with the use of the Monte Carlo code is higher than the one obtained from the deterministic code.

  14. Sucker rod string design of the pumping systems

    Directory of Open Access Journals (Sweden)

    Chun Hua Liu

    2015-08-01

    Full Text Available The existing design of sucker rod string mainly focuses on the simplifying assumptions that rod string was exposed to simple tension loading. And its goal was to have equal modified stress at the top of each taper. The improved rod design was to have the same degree of safety at each section, and it used a dynamic force distribution that was proportional along the whole string. However, the available procedures did not provide the desired accuracy of its pertinent analysis, and the operators could not identify the specific phenomena that occur in CBM wells. In this paper, the mathematical models of rod loads and string length were developed based on the cyclic nature of rod string loading; the fatigue endurance method is used to design the single rod string; and the tapered rod string is designed to have an equal equivalent stress at the top of each section. Its application characteristics are demonstrated by the example of CBM wells in Ordos Basin. The interpretations of results show that the previous design gave the single rods a larger diameter and the top rods in the string a greater percent than the proposed method. The calculation should concern about inertial, vibration and friction forces to illustrate the elastic force waves travelling in the rod material with the speed of sound. The single string should be designed using fatigue endurance ratings due to asymmetric pulsating tension of rod loading; and the tapered string should involve a balanced design by setting the fatigue endurance at each section equal. A shorter stroke length gives a greater rod taper percentage and an increased load capacity results to an enhanced rod diameter. The rod diameter increases with the pump size and load capacity for the single string, and the rod taper percentage of the top rod strings increases with plunger diameter for the tapered string. The proposed research improves efficiency of the pumping system, assures good operating conditions, and reduces

  15. Investigation of control rod worth and nuclear end of life of BWR control rods

    Energy Technology Data Exchange (ETDEWEB)

    Magnusson, Per

    2008-01-15

    This work has investigated the Control Rod Worth (CRW) and Nuclear End of Life (NEOL) values for BWR control rods. A study of how different parameters affect NEOL was performed with the transport code PHOENIX4. It was found that NEOL, expressed in terms of {sup 10}B depletion, can be generalized beyond the conditions for which the rod is depleted, such as different power densities and void fractions, the corresponding variation in the NEOL will be about 0.2-0.4% {sup 10}B. It was also found that NEOL results for different fuel types and different fuel enrichments have a variation of about 2-3% in {sup 10}B depletion. A comparative study on NHOL and CRW was made between PHOENIX4 and the stochastic Monte Carlo code MCNP. It was found that there is a significant difference, both due to differences in the codes and to limitations in the geometrical modeling in PHOENIX4. Since MCNP is considered more physically correct, a methodology was developed to calculate the nuclear end of life of BWR control rods with MCNP. The advantages of the methodology are that it does not require other codes to perform the depletion of the absorber material, it can describe control rods of any design and it can deplete the control rod absorber material without burning the fuel. The disadvantage of the method is that is it time-consuming.

  16. Mechanisms, pools, and sites of spontaneous vesicle release at synapses of rod and cone photoreceptors.

    Science.gov (United States)

    Cork, Karlene M; Van Hook, Matthew J; Thoreson, Wallace B

    2016-08-01

    Photoreceptors have depolarized resting potentials that stimulate calcium-dependent release continuously from a large vesicle pool but neurons can also release vesicles without stimulation. We characterized the Ca(2+) dependence, vesicle pools, and release sites involved in spontaneous release at photoreceptor ribbon synapses. In whole-cell recordings from light-adapted horizontal cells (HCs) of tiger salamander retina, we detected miniature excitatory post-synaptic currents (mEPSCs) when no stimulation was applied to promote exocytosis. Blocking Ca(2+) influx by lowering extracellular Ca(2+) , by application of Cd(2+) and other agents reduced the frequency of mEPSCs but did not eliminate them, indicating that mEPSCs can occur independently of Ca(2+) . We also measured release presynaptically from rods and cones by examining quantal glutamate transporter anion currents. Presynaptic quantal event frequency was reduced by Cd(2+) or by increased intracellular Ca(2+) buffering in rods, but not in cones, that were voltage clamped at -70 mV. By inhibiting the vesicle cycle with bafilomycin, we found the frequency of mEPSCs declined more rapidly than the amplitude of evoked excitatory post-synaptic currents (EPSCs) suggesting a possible separation between vesicle pools in evoked and spontaneous exocytosis. We mapped sites of Ca(2+) -independent release using total internal reflectance fluorescence (TIRF) microscopy to visualize fusion of individual vesicles loaded with dextran-conjugated pHrodo. Spontaneous release in rods occurred more frequently at non-ribbon sites than evoked release events. The function of Ca(2+) -independent spontaneous release at continuously active photoreceptor synapses remains unclear, but the low frequency of spontaneous quanta limits their impact on noise.

  17. Rod Has High Tensile Strength And Low Thermal Expansion

    Science.gov (United States)

    Smith, D. E.; Everton, R. L.; Howe, E.; O'Malley, M.

    1996-01-01

    Thoriated tungsten extension rod fabricated to replace stainless-steel extension rod attached to linear variable-differential transformer in gap-measuring gauge. Threads formed on end of rod by machining with special fixtures and carefully chosen combination of speeds and feeds.

  18. 77 FR 1504 - Stainless Steel Wire Rod From India

    Science.gov (United States)

    2012-01-10

    ... COMMISSION Stainless Steel Wire Rod From India Determination On the basis of the record \\1\\ developed in the... antidumping duty order on stainless steel wire rod From India would be likely to lead to continuation or... contained in USITC Publication 4300 (January 2012), entitled Stainless Steel Wire Rod From...

  19. Carbon Inverse Opal Rods for Nonenzymatic Cholesterol Detection.

    Science.gov (United States)

    Zhong, Qifeng; Xie, Zhuoying; Ding, Haibo; Zhu, Cun; Yang, Zixue; Gu, Zhongze

    2015-11-18

    Carbon inverse opal rods made from silica photonic crystal rods are used for nonenzymatic cholesterol sensing. The characteristic reflection peak originating from the physical periodic structure works as sensing signals for quantitatively estimating cholesterol concentrations. Carbon inverse opal rods work both in cholesterol standard solutions and human serum. They are suitable for practical use in clinical diagnose.

  20. Incorporation of calcium buffers into salamander retinal rods: a rejection of the calcium hypothesis of phototransduction.

    Science.gov (United States)

    Lamb, T D; Matthews, H R; Torre, V

    1986-03-01

    The suction-electrode technique was used to monitor the photocurrent of isolated retinal rods from the tiger salamander, by drawing in the light-sensitive outer segment, or sometimes the inner segment. Calcium buffers or other agents were then introduced into the rod cytoplasm by the 'whole-cell patch-clamp' technique. A patch pipette was sealed against the region of the rod protruding from the suction pipette (usually the inner segment), and the membrane patch was ruptured to obtain a whole-cell recording. Several lines of evidence indicated that the pipette contents diffused into the outer segment, and showed that the cell could be adequately voltage clamped. With only trace quantities of chelator in the patch pipette (to bind stray calcium), a gradual decline of the dark current and slowing of responses was usually observed over a period of 10-20 min after rupture of the patch. When the patch pipette contained no added calcium and 10 mM of the calcium chelator BAPTA (1,2-bis(o-aminophenoxy)ethane-N,N,N',N'-tetraacetic acid) (free Ca2+ ca. 10(-9) M) rupture of the patch led, over a period of a few minutes, to an increase in mean dark current, an increased duration of responses, a substantial increase in flash sensitivity, and a pronounced overshoot in the recovery phase, but with virtually no change in the rising phase of the response to bright flashes. Similar results were obtained when EGTA was used in place of BAPTA, and also in the few cases when successful rupture of the outer segment membrane was obtained. With the free calcium concentration in the patch pipette buffered to the higher level of 1 microM (with 10 mM-Ca2+/11 mM-BAPTA) the results were qualitatively similar to those obtained with BAPTA alone, except that the mean dark current did not increase. This is consistent with a resting free calcium concentration in darkness in the region of 1 microM. In the presence of bright steady illumination with BAPTA in the cell the suppression of outer segment

  1. SEMICONDUCTOR PHYSICS: Frequency of the transition spectral line of an electron in quantum rods

    Science.gov (United States)

    Guiwen, Wang; Jingling, Xiao

    2010-09-01

    The Hamiltonian of a quantum rod with an ellipsoidal boundary is given after a coordinate transformation which changes the ellipsoidal boundary into a spherical one. We then study the first internal excited state energy, the excitation energy and the frequency of the transition spectral line between the first internal excited state and the ground state of the strong-coupling polaron in a quantum rod. The effects of the electron-phonon coupling strength, the aspect ratio of the ellipsoid, the transverse radius of quantum rods and the transverse and longitudinal effective confinement length are taken into consideration by using a linear combination operator and the unitary transformation methods. It is found that the first internal excited state energy, the excitation energy and the frequency of the transition spectral line are increasing functions of the electron-phonon coupling strength, whereas they are decreasing ones of the transverse radius of quantum rods and the aspect ratio. The first internal excited state energy, the excitation energy and the frequency of the transition spectral line increase with decreasing transverse and longitudinal effective confinement length.

  2. Current umbilical cord clamping practices and attitudes of obstetricians and midwives toward delayed cord clamping in Saudi Arabia.

    Science.gov (United States)

    Ibrahim, Nadia O; Sukkarieh, Hatouf H; Bustami, Rami T; Alshammari, Elaf A; Alasmari, Lama Y; Al-Kadri, Hanan M

    2017-01-01

    In Saudi Arabia, as in many countries, there is usually no clear definition of the timing of umbilical cord clamping (UCC) in the policies and procedures used by hospitals. The World Health Organization (WHO) recommends delayed cord clamping (DCC) ( > 1 minute after birth) as it can significantly improve hemodynamics and long-term neurodevelopment. To investigate current practices of healthcare professionals on the timing of UCC in Saudi Arabia. Cross-sectional survey. Five tertiary hospitals in Riyadh, Saudi Arabia, during May to October 2016. Obstetricians and midwives completed a widely-used questionnaire on UCC practices. Current UCC practices and attitudes of obstetricians and midwives toward DCC. Eighty-two obstetricians and 75 midwives completed the questionnaire for a response rate of 80%. The majority of respondents were aged 30 years or older (81%) and 84% were females. Most respondents were non-Saudi (66%) and had an educational level of bachelor's degree or higher (72%). Only 42% of respondents reported the existence of UCC guidelines in their practice; 38% reported the existence of a set time for UCC when the neonate was term and healthy, and only 32% had a set time for UCC in preterm neonates. While lower levels of agreement were reported among obstetricians and midwives on the benefits of DCC for babies requiring positive pressure ventilation, the majority of respondents (69-71%) thought that DCC was generally good for both term and preterm babies and that its benefits extend beyond the neonatal period. While the majority of obstetricians and midwives that participated in this study had a positive perception toward DCC, this did not translate to their daily practice as most of these professionals reported a lack of existing UCC guidelines in their institutions. Further studies are warranted to confirm these findings. Participant selection by convenience sampling.

  3. STUDY ON A HYDROPHOBIC-HYDROPHILIC GRADIENT ROD

    Institute of Scientific and Technical Information of China (English)

    Jun Ma; Bai-yu Li; Hai-yun Liu; Zhi-min Zheng; Jian Xu

    2004-01-01

    A hydrophobic-hydrophilic gradient rod with a length of 40 mm and a diameter of 3 mm was prepared by heating a polymethylsilsesquioxane rod in a cylindrical stove with temperature gradient. The rod was thus pyrolyzed under a temperature gradient condition. The organic end of the gradient rod appears hydrophobic with a contact angle of 109.9° while the other end is hydrophilic with a contact angle of 62.4°. The gradient chemical structure and the gradient microstructure along the rod were characterized by FTIR and SEM, respectively.

  4. Test Research on Special Sucker Rod for Screw Pump

    Institute of Scientific and Technical Information of China (English)

    Zhang Mingyi; Chen Mingzhan; Li Zhi

    2006-01-01

    @@ According to the statistics of straight thread sucker rods' application in screw pump in Daqing Oilfield before2000, the proportion of sucker rods' yearly breakaway reached to 41.6%, taking up 70% of the total wells that were checked. Thus it can be seen that the rods breakaway problem was becoming the main barrier restricting screw pump large-scale population and application. Since then,the development work on the special sucker rods for screw pump had been carried on. Through the analysis on the failure position and failure form of the sucker rods',the following conclusions arepresented:

  5. Grounded cognition.

    Science.gov (United States)

    Barsalou, Lawrence W

    2008-01-01

    Grounded cognition rejects traditional views that cognition is computation on amodal symbols in a modular system, independent of the brain's modal systems for perception, action, and introspection. Instead, grounded cognition proposes that modal simulations, bodily states, and situated action underlie cognition. Accumulating behavioral and neural evidence supporting this view is reviewed from research on perception, memory, knowledge, language, thought, social cognition, and development. Theories of grounded cognition are also reviewed, as are origins of the area and common misperceptions of it. Theoretical, empirical, and methodological issues are raised whose future treatment is likely to affect the growth and impact of grounded cognition.

  6. Photonic mesophases from cut rod rotators

    Energy Technology Data Exchange (ETDEWEB)

    Stelson, Angela C.; Liddell Watson, Chekesha M., E-mail: cml66@cornell.edu [Materials Science and Engineering, Cornell University, Ithaca, New York 14853 (United States); Avendano, Carlos [Chemical Engineering and Analytical Science, The University of Manchester, Manchester M13 9PL (United Kingdom)

    2016-01-14

    The photonic band properties of random rotator mesophases are calculated using supercell methods applied to cut rods on a hexagonal lattice. Inspired by the thermodynamic mesophase for anisotropic building blocks, we vary the shape factor of cut fraction for the randomly oriented basis. We find large, stable bandgaps with high gap isotropy in the inverted and direct structures as a function of cut fraction, dielectric contrast, and filling fraction. Bandgap sizes up to 34.5% are maximized at high dielectric contrast for rods separated in a matrix. The bandgaps open at dielectric contrasts as low as 2.0 for the transverse magnetic polarization and 2.25 for the transverse electric polarization. Additionally, the type of scattering that promotes the bandgap is correlated with the effect of disorder on bandgap size. Slow light properties are investigated in waveguide geometry and slowdown factors up to 5 × 10{sup 4} are found.

  7. Oligo(naphthylene–ethynylene) Molecular Rods

    DEFF Research Database (Denmark)

    Cramer, Jacob Roland; Ning, Yanxiao; Shen, Cai;

    2013-01-01

    Molecular rods designed for surface chirality studies have been synthesized in high yields. The molecules are composed of oligo(naphthylene–ethynylene) skeletons and functionalized at their two termini with carboxylic acids and hydrophobic groups. The molecular skeletons were constructed by means...... of palladium-catalyzed Sonogashira reactions between naphthyl halides and acetylenes. The triazene functionality was used as a protected iodine precursor to allow linear extension of the molecular rods during the synthe-ses. The carboxylic acid groups in the target molecules were protected as esters during...... the synthesis to keep the large aromatic molecules soluble during their syntheses. These rigid oligomers were designed to form lamella-like structures when adsorbed on a surface, through which multiple distinguishable surface conformations should be obtainable. Preliminary scanning tunneling microscopy imaging...

  8. [Rod of Asclepius. Symbol of medicine].

    Science.gov (United States)

    Young, Pablo; Finn, Bárbara C; Bruetman, Julio E; Cesaro Gelos, Jorge; Trimarchi, Hernán

    2013-09-01

    Symbolism is one of the most archaic forms of human thoughts. Symbol derives from the Latin word symbolum, and the latter from the Greek symbolon or symballo, which means "I coincide, I make matches". The Medicine symbol represents a whole series of historical and ethical values. Asclepius Rod with one serpent entwined, has traditionally been the symbol of scientific medicine. In a misconception that has lasted 500 years, the Caduceus of Hermes, entwined by two serpents and with two wings, has been considered the symbol of Medicine. However, the Caduceus is the current symbol of Commerce. Asclepius Rod and the Caduceus of Hermes represent two professions, Medicine and Commerce that, in ethical practice, should not be mixed. Physicians should be aware of their real emblem, its historical origin and meaning.

  9. Composites reinforcement by rods: a SAS study

    Energy Technology Data Exchange (ETDEWEB)

    Urban, V. [ESRF, BP220, 38043 Grenoble Cedex (France); Botti, A.; Pyckhout-Hintzen, W.; Richter, D. [IFF-Forschungszentrum Juelich, 52425 Juelich (Germany); Straube, E. [University of Halle, FB Physik, 06099 Halle (Germany)

    2002-07-01

    The mechanical properties of composites are governed by size, shape and dispersion degree of so-called reinforcing particles. Polymeric fillers based on thermodynamically driven microphase separation of block copolymers offer the opportunity to study a model system of controlled rod-like filler particles. We chose a triblock copolymer (PBPSPB) and carried out SAS measurements with both X-rays and neutrons, in order to characterize separately the hard phase and the cross-linked PB matrix. The properties of the material depend strongly on the way that stress is carried and transferred between the soft matrix and the hard fibers. The failure of the strain-amplification concept and the change of topological contributions to the free energy and scattering factor have to be addressed. In this respect the composite shows a similarity to a two-network system, i.e. interpenetrating rubber and rod-like filler networks. (orig.)

  10. Composites reinforcement by rods a SAS study

    CERN Document Server

    Urban, V; Pyckhout-Hintzen, W; Richter, D; Straube, E

    2002-01-01

    The mechanical properties of composites are governed by size, shape and dispersion degree of so-called reinforcing particles. Polymeric fillers based on thermodynamically driven microphase separation of block copolymers offer the opportunity to study a model system of controlled rod-like filler particles. We chose a triblock copolymer (PBPSPB) and carried out SAS measurements with both X-rays and neutrons, in order to characterize separately the hard phase and the cross-linked PB matrix. The properties of the material depend strongly on the way that stress is carried and transferred between the soft matrix and the hard fibers. The failure of the strain-amplification concept and the change of topological contributions to the free energy and scattering factor have to be addressed. In this respect the composite shows a similarity to a two-network system, i.e. interpenetrating rubber and rod-like filler networks. (orig.)

  11. Instabilities of a rotating helical rod

    Science.gov (United States)

    Park, Yunyoung; Ko, William; Kim, Yongsam; Lim, Sookkyung

    2016-11-01

    Bacteria such as Escherichia coli and Vibrio alginolyticus have helical flagellar filament. By rotating a motor, which is located at the bottom end of the flagellar filament embedded in the cell body, CCW or CW, they swim forward or backward. We model a left-handed helix by the Kirchhoff rod theory and use regularized Stokes formulation to study an interaction between the surrounding fluid and the flagellar filament. We perform numerical studies focusing on relations between physical parameters and critical angular frequency of the motor, which separates overwhiring from twirling. We are also interested in the buckling instability of the hook, which is very flexible elastic rod. By measuring buckling angle, which is an angle between rotational axis and helical axis, we observe the effects of physical parameters on buckling of the hook.

  12. Structural insight into β-Clamp and its interaction with DNA Ligase in Helicobacter pylori.

    Science.gov (United States)

    Pandey, Preeti; Tarique, Khaja Faisal; Mazumder, Mohit; Rehman, Syed Arif Abdul; Kumari, Nilima; Gourinath, Samudrala

    2016-08-08

    Helicobacter pylori, a gram-negative and microaerophilic bacterium, is the major cause of chronic gastritis, gastric ulcers and gastric cancer. Owing to its central role, DNA replication machinery has emerged as a prime target for the development of antimicrobial drugs. Here, we report 2Å structure of β-clamp from H. pylori (Hpβ-clamp), which is one of the critical components of DNA polymerase III. Despite of similarity in the overall fold of eubacterial β-clamp structures, some distinct features in DNA interacting loops exists that have not been reported previously. The in silico prediction identified the potential binders of β-clamp such as alpha subunit of DNA pol III and DNA ligase with identification of β-clamp binding regions in them and validated by SPR studies. Hpβ-clamp interacts with DNA ligase in micromolar binding affinity. Moreover, we have successfully determined the co-crystal structure of β-clamp with peptide from DNA ligase (not reported earlier in prokaryotes) revealing the region from ligase that interacts with β-clamp.

  13. The transducer domain is important for clamp operation in human DNA topoisomerase IIalpha

    DEFF Research Database (Denmark)

    Oestergaard, Vibe H; Bjergbaek, Lotte; Skouboe, Camilla

    2003-01-01

    the clamp to the enzyme core. Although structurally conserved, it is unclear whether the transducer domain is involved in clamp mechanism. We have purified and characterized a human topoisomerase II alpha enzyme with a two-amino acid insertion at position 408 in the transducer domain. The enzyme retains...

  14. Angiotensin II clamp prevents the second step in renal apical NHE3 internalization during acute hypertension

    DEFF Research Database (Denmark)

    Leong, Patrick K K; Yang, Li E; McDonough, Alicia A

    2002-01-01

    . Plasma ANG II concentration of anesthesized Sprague-Dawley rats was clamped by simultaneous infusion of the ANG I-converting enzyme inhibitor captopril (12 microg/min) and ANG II (20 ng. kg(-1). min(-1)). Blood pressure was increased 50 mmHg for 20 min by arterial constriction +/- ANG II clamp or by sham...

  15. Implementing dynamic clamp with synaptic and artificial conductances in mouse retinal ganglion cells.

    Science.gov (United States)

    Huang, Jin Y; Stiefel, Klaus M; Protti, Dario A

    2013-05-16

    Ganglion cells are the output neurons of the retina and their activity reflects the integration of multiple synaptic inputs arising from specific neural circuits. Patch clamp techniques, in voltage clamp and current clamp configurations, are commonly used to study the physiological properties of neurons and to characterize their synaptic inputs. Although the application of these techniques is highly informative, they pose various limitations. For example, it is difficult to quantify how the precise interactions of excitatory and inhibitory inputs determine response output. To address this issue, we used a modified current clamp technique, dynamic clamp, also called conductance clamp (1, 2, 3) and examined the impact of excitatory and inhibitory synaptic inputs on neuronal excitability. This technique requires the injection of current into the cell and is dependent on the real-time feedback of its membrane potential at that time. The injected current is calculated from predetermined excitatory and inhibitory synaptic conductances, their reversal potentials and the cell's instantaneous membrane potential. Details on the experimental procedures, patch clamping cells to achieve a whole-cell configuration and employment of the dynamic clamp technique are illustrated in this video article. Here, we show the responses of mouse retinal ganglion cells to various conductance waveforms obtained from physiological experiments in control conditions or in the presence of drugs. Furthermore, we show the use of artificial excitatory and inhibitory conductances generated using alpha functions to investigate the responses of the cells.

  16. Hollow Sucker Rod Applied in Production Engineering

    Institute of Scientific and Technical Information of China (English)

    Wang Tongbin; Liu Liandong; Hu Daoming; Jia Yanshan

    1997-01-01

    @@ Working Principle A positive cycle system or a working channel can be formed by means of hollow sucker rod and its mating parts in the oil tube ofa well, through which heat carriers (such as hot water,hot oil and steam), chemicals and heating cable can be pumped or put into the well so as to lower the viscosity of crude, dissolve the paraffin building-up and open the conduit, thus leading to the smooth oil flow out of well.

  17. Rod Driven Frequency Entrainment and Resonance Phenomena

    Directory of Open Access Journals (Sweden)

    Christina Salchow

    2016-08-01

    Full Text Available A controversy exists on photic driving in the human visual cortex evoked by intermittent photic stimulation. Frequency entrainment and resonance phenomena are reported for frequencies higher than 12 Hz in some studies while missing in others. We hypothesized that this might be due to different experimental conditions, since both high and low intensity light stimulation were used. However, most studies do not report radiometric measurements, which makes it impossible to categorize the stimulation according to photopic, mesopic, and scotopic vision. Low intensity light stimulation might lead to scotopic vision, where rod perception dominates. In this study, we investigated photic driving for rod-dominated visual input under scotopic conditions. Twelve healthy volunteers were stimulated with low intensity light flashes at 20 stimulation frequencies, leading to rod activation only. The frequencies were multiples of the individual alpha frequency (α of each volunteer in the range from 0.40–2.30*α. 306-channel whole head magnetoencephalography recordings were analyzed in time, frequency, and spatiotemporal domains with the Topographic Matching Pursuit algorithm. We found resonance phenomena and frequency entrainment for stimulations at or close to the individual alpha frequency (0.90–1.10*α and half of the alpha frequency (0.40–0.55*α. No signs of resonance and frequency entrainment phenomena were revealed around 2.00*α. Instead, on-responses at the beginning and off-responses at the end of each stimulation train were observed for the first time in a photic driving experiment at frequencies of 1.30–2.30*α, indicating that the flicker fusion threshold was reached. All results, the resonance and entrainment as well as the fusion effects, provide evidence for rod-dominated photic driving in the visual cortex.

  18. Rod Driven Frequency Entrainment and Resonance Phenomena

    Science.gov (United States)

    Salchow, Christina; Strohmeier, Daniel; Klee, Sascha; Jannek, Dunja; Schiecke, Karin; Witte, Herbert; Nehorai, Arye; Haueisen, Jens

    2016-01-01

    A controversy exists on photic driving in the human visual cortex evoked by intermittent photic stimulation. Frequency entrainment and resonance phenomena are reported for frequencies higher than 12 Hz in some studies while missing in others. We hypothesized that this might be due to different experimental conditions, since both high and low intensity light stimulation were used. However, most studies do not report radiometric measurements, which makes it impossible to categorize the stimulation according to photopic, mesopic, and scotopic vision. Low intensity light stimulation might lead to scotopic vision, where rod perception dominates. In this study, we investigated photic driving for rod-dominated visual input under scotopic conditions. Twelve healthy volunteers were stimulated with low intensity light flashes at 20 stimulation frequencies, leading to rod activation only. The frequencies were multiples of the individual alpha frequency (α) of each volunteer in the range from 0.40 to 2.30∗α. Three hundred and six-channel whole head magnetoencephalography recordings were analyzed in time, frequency, and spatiotemporal domains with the Topographic Matching Pursuit algorithm. We found resonance phenomena and frequency entrainment for stimulations at or close to the individual alpha frequency (0.90–1.10∗α) and half of the alpha frequency (0.40–0.55∗α). No signs of resonance and frequency entrainment phenomena were revealed around 2.00∗α. Instead, on-responses at the beginning and off-responses at the end of each stimulation train were observed for the first time in a photic driving experiment at frequencies of 1.30–2.30∗α, indicating that the flicker fusion threshold was reached. All results, the resonance and entrainment as well as the fusion effects, provide evidence for rod-dominated photic driving in the visual cortex. PMID:27588002

  19. Belt Clamping Device for Flat Screen Magnet Printing Machine%平网磁棒印花机导带压紧装置

    Institute of Scientific and Technical Information of China (English)

    朱红军; 寇恒梅

    2013-01-01

    本文阐述了一种平网磁棒印花机导带压紧装置,它置于版框架上,包括旋合式上下离合套、螺纹座、联接杆、压缩弹簧、导向块、导带压块、橡胶套、长螺杆及版框架。当版框架下降时,导带压块通过压缩弹簧的反作用力即可牢牢压住导带,防止导带位移而造成花型错位。当需要版框落下对花型时,只需旋转离合套一角度,便能快捷地抬离导带压块,实现了版框落下对花的问题。%This paper describes belt clamping device for flat screen magnet printing machine, which is placed on the frame version, including the upper and lower clutch set screw type, thread blocks, connecting rods, compression springs, guide block, the conduction band clamps, rubber sleeve long screw and a version of the framework. When a version of the framework falls, the conduction band of the reaction force of the compression spring clamps to firmly hold the conduction band, prevent displacement of the conduction band pattern caused dislocation. When you need to fall on the flower box version, just rotate the clutch cover an angle, we will be able to lift off the fast conduction band briquetting and achieve edition box fall on the registration issue.

  20. ELECTROMAGNETIC APPARATUS FOR MOVING A ROD

    Science.gov (United States)

    Young, J.N.

    1957-08-20

    An electromagnetic device for moving an object in a linear path by increments is described. The device is specifically adapted for moving a neutron absorbing control rod into and out of the core of a reactor and consists essentially of an extension member made of magnetic material connected to one end of the control rod and mechanically flexible to grip the walls of a sleeve member when flexed, a magnetic sleeve member coaxial with and slidable between limit stops along the flexible extension, electromagnetic coils substantially centrally located with respect to the flexible extension to flex the extension member into gripping engagement with the sleeve member when ener gized, moving electromagnets at each end of the sleeve to attract the sleeve when energized, and a second gripping electromagnet positioned along the flexible extension at a distance from the previously mentioned electromagnets for gripping the extension member when energized. In use, the second gripping electromagnet is deenergized, the first gripping electromagnet is energized to fix the extension member in the sleeve, and one of the moving electromagnets is energized to attract the sleeve member toward it, thereby moving the control rod.

  1. Description and characterization of HBWR Series H-1 test rods

    Energy Technology Data Exchange (ETDEWEB)

    Wagoner, S.R.; Barner, J.O.; Welty, R.K.

    1979-06-01

    The as-built characterization results are presented for the HBWR Series H-1 test rods to be irradiated as part of the Fuel Performance Improvement Program (FPIP). The irradiation of these rods is to be conducted in the Halden Boiling Water Reactor (HBWR). Series H-1 consists of twelve rods for irradiation and six spares. Rod design types include (1) a reference dished pellet design, (2) an annular pellet design, (3) an annular pellet design combined with graphite-coated cladding, and (4) a packed-particle (vipac) design. The report, which describes the fabrication and detailed characterization results for the rods, is divided into four major sections: (1) experiment description, (2) process development required to fabricate the test rods, (3) methods and procedures used to fabricate and characterize the rods, and (4) a summary of the characterization results.

  2. Nuclear thermionic converter. [tungsten-thorium oxide rods

    Science.gov (United States)

    Phillips, W. M.; Mondt, J. F. (Inventor)

    1977-01-01

    Efficient nuclear reactor thermionic converter units are described which can be constructed at low cost and assembled in a reactor which requires a minimum of fuel. Each converter unit utilizes an emitter rod with a fluted exterior, several fuel passages located in the bulges that are formed in the rod between the flutes, and a collector receiving passage formed through the center of the rod. An array of rods is closely packed in an interfitting arrangement, with the bulges of the rods received in the recesses formed between the bulges of other rods, thereby closely packing the nuclear fuel. The rods are constructed of a mixture of tungsten and thorium oxide to provide high power output, high efficiency, high strength, and good machinability.

  3. Effect of delayed cord clamping on very preterm infants.

    Science.gov (United States)

    Chiruvolu, Arpitha; Tolia, Veeral N; Qin, Huanying; Stone, Genna Leal; Rich, Diana; Conant, Rhoda J; Inzer, Robert W

    2015-11-01

    Despite significant proposed benefits, delayed umbilical cord clamping (DCC) is not practiced widely in preterm infants largely because of the question of feasibility of the procedure and uncertainty regarding the magnitude of the reported benefits, especially intraventricular hemorrhage (IVH) vs the adverse consequences of delaying the neonatal resuscitation. The objective of this study was to determine whether implementation of the protocol-driven DCC process in our institution would reduce the incidence of IVH in very preterm infants without adverse consequences. We implemented a quality improvement process for DCC the started in August 2013 in infants born at ≤32 weeks' gestational age. Eligible infants were left attached to the placenta for 45 seconds after birth. Neonatal process and outcome data were collected until discharge. We compared infants who received DCC who were born between August 2013 and August 2014 with a historic cohort of infants who were born between August 2012 and August 2013, who were eligible to receive DCC, but whose cord was clamped immediately after birth, because they were born before the protocol implementation. DCC was performed on all the 60 eligible infants; 88 infants were identified as historic control subjects. Gestational age, birthweight, and other demographic variables were similar between both groups. There were no differences in Apgar scores or admission temperature, but significantly fewer infants in the DCC cohort were intubated in delivery room, had respiratory distress syndrome, or received red blood cell transfusions in the first week of life compared with the historic cohort. A significant reduction was noted in the incidence of IVH in the DCC cohort compared with the historic control group (18.3% vs 35.2%). After adjustment for gestational age, an association was found between the incidence of IVH and DCC with IVH was significantly lower in the DCC cohort compared with the historic cohort; an odds ratio of 0

  4. On the mechanism of loading the PCNA sliding clamp by RFC.

    Science.gov (United States)

    Dionne, Isabelle; Brown, Nicola J; Woodgate, Roger; Bell, Stephen D

    2008-04-01

    Sliding clamps play central roles in a broad range of DNA replication and repair processes. The clamps form circular molecules that must be opened and resealed around DNA by the clamp loader complex to fulfil their function. While most eukaryotes and many archea possess a homo-trimeric PCNA, the PCNA of Sulfolobus solfataricus is a heterotrimer. Here, we exploit the asymmetry of S. solfataricus PCNA to create a series of circularly permuted PCNA subunit fusions, thereby covalently closing defined interfaces within the heterotrimer. Using these concatamers, we investigate the requirements for loading the clamp onto DNA and reveal that a single defined interface within the heterotrimer is opened during the loading process. Subunit-specific interactions between S. solfataricus RFC clamp loader and PCNA permit us to superimpose our data upon the structure of yeast RFC-PCNA complex, thereby presenting a general model for PCNA loading by RFC in archaea and eukaryotes.

  5. A reduction clamp for an aiming component in associated acetabular fractures

    Directory of Open Access Journals (Sweden)

    Zhang-Fu Wang

    2015-01-01

    Full Text Available Background: The treatment of acetabular fractures is complex and requires specialized equipment. However, all currently available instruments have some disadvantages. A new reduction clamp that can firmly enable reduction and not hinder subsequent fixation procedures for some special fracture types is needed. Materials and Methods: In this study, we introduce a new acetabular clamp and its preliminary clinical application in three T-shaped acetabular fractures. Results: This new clamp can successfully pull the posterior column back to the anterior column and firmly maintain the reduction. This clamp′s aiming plate can facilitate the insertion of long lag screws. The clamp is also easy to assemble and use. Conclusion: This reduction clamp is a useful instrument that can facilitate open reduction and internal fixation of acetabular fractures.

  6. Note: High-efficiency energy harvester using double-clamped piezoelectric beams

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Yingmei; Wu, Xuan; Parmar, Mitesh; Lee, Dong-weon, E-mail: mems@jnu.ac.kr [MEMS and Nanotechnology Laboratory, School of Mechanical Systems Engineering, Chonnam National University, Gwangju (Korea, Republic of)

    2014-02-15

    In this study, an improvement in energy conversion efficiency has been reported, which is realized by using a double-clamped piezoelectric beam, based on uniaxial stretching strain. The buckling mechanism is applied to maximize axial stress in the double-clamped beam. The voltage generated by using the double-clamped piezoelectric beam is higher than that generated by using other conventional structures, such as bending cantilevers coated/sandwiched with piezoelectric film, which is proven both theoretically and experimentally. The power generation efficiency is enhanced by further optimizing the double-clamped structure. The optimized high-efficiency energy harvester utilizing double-clamped piezoelectric beams generates a peak output power of 80 μW, under an acceleration of 0.1g.

  7. Note: high-efficiency energy harvester using double-clamped piezoelectric beams.

    Science.gov (United States)

    Zheng, Yingmei; Wu, Xuan; Parmar, Mitesh; Lee, Dong-weon

    2014-02-01

    In this study, an improvement in energy conversion efficiency has been reported, which is realized by using a double-clamped piezoelectric beam, based on uniaxial stretching strain. The buckling mechanism is applied to maximize axial stress in the double-clamped beam. The voltage generated by using the double-clamped piezoelectric beam is higher than that generated by using other conventional structures, such as bending cantilevers coated/sandwiched with piezoelectric film, which is proven both theoretically and experimentally. The power generation efficiency is enhanced by further optimizing the double-clamped structure. The optimized high-efficiency energy harvester utilizing double-clamped piezoelectric beams generates a peak output power of 80 μW, under an acceleration of 0.1g.

  8. Rod and Rod-driven Function in Achromatopsia and Blue Cone Monochromatism

    Science.gov (United States)

    Moskowitz, Anne; Hansen, Ronald M.; Akula, James D.; Eklund, Susan E.; Fulton, Anne B.

    2008-01-01

    Purpose To evaluate rod photoreceptor and postreceptor retinal function in pediatric patients with achromatopsia (ACHR) and blue cone monochromatism (BCM) using contemporary electroretinographic (ERG) procedures. Methods Fifteen patients (age 1 to 20 years) with ACHR and six patients (age 4 to 22 years) with BCM were studied. ERG responses to full-field stimuli were obtained in scotopic and photopic conditions. Rod photoreceptor (Srod, Rrod) and rod-driven postreceptor (log σ, Vmax) response parameters were calculated from the a-wave and b-wave. The ERG records were digitally filtered to demonstrate the oscillatory potentials (OPs); a sensitivity parameter, log SOPA1/2, and an amplitude parameter, SOPAmax, were used to characterize the OP response. Response parameters were compared to those of 12 normal control subjects. Results As expected, photopic responses were non-detectable in patients with ACHR and BCM. In addition, mean scotopic photoreceptor (Rrod) and postreceptor (Vmax and SOPAmax) amplitude parameters were significantly reduced compared to those in normal controls. The flash intensity required to evoke a half maximum b-wave amplitude (log σ) was significantly increased. Conclusions The results of this study provide evidence that deficits in rod and rod mediated function occur in the primary cone dysfunction syndromes, achromatopsia and blue cone monochromatism. PMID:18824728

  9. Effects of Delayed Umbilical Cord Clamping vs Early Clamping on Anemia in Infants at 8 and 12 Months: A Randomized Clinical Trial.

    Science.gov (United States)

    Kc, Ashish; Rana, Nisha; Målqvist, Mats; Jarawka Ranneberg, Linda; Subedi, Kalpana; Andersson, Ola

    2017-03-01

    Delayed umbilical cord clamping has been shown to improve iron stores in infants to 6 months of age. However, delayed cord clamping has not been shown to prevent iron deficiency or anemia after 6 months of age. To investigate the effects of delayed umbilical cord clamping, compared with early clamping, on hemoglobin and ferritin levels at 8 and 12 months of age in infants at high risk for iron deficiency anemia. This randomized clinical trial included 540 late preterm and term infants born vaginally at a tertiary hospital in Kathmandu, Nepal, from October 2 to November 21, 2014. Follow-up included blood levels of hemoglobin and ferritin at 8 and 12 months of age. Follow-up was completed on December 11, 2015. Analysis was based on intention to treat. Infants were randomized to delayed umbilical cord clamping (≥180 seconds after delivery) or early clamping (≤60 seconds after delivery). Main outcomes included hemoglobin and anemia levels at 8 months of age with the power estimate based on the prevalence of anemia. Secondary outcomes included hemoglobin and anemia levels at 12 months of age and ferritin level, iron deficiency, and iron deficiency anemia at 8 and 12 months of age. In this study of 540 infants (281 boys [52.0%] and 259 girls [48.0%]; mean [SD] gestational age, 39.2 [1.1] weeks), 270 each were randomized to the delayed and early clamping groups. At 8 months of age, 212 infants (78.5%) from the delayed group and 188 (69.6%) from the early clamping group returned for blood sampling. After multiple imputation analysis, infants undergoing delayed clamping had higher levels of hemoglobin (10.4 vs 10.2 g/dL; difference, 0.2 g/dL; 95% CI, 0.1 to 0.4 g/dL). Delayed cord clamping also reduced the prevalence of anemia (hemoglobin level clamping group in 60 (22.2%) vs 103 (38.1%) patients (relative risk, 0.58; 95% CI, 0.44-0.77; NNT, 6; 95% CI, 4-13). At 12 months, delayed cord clamping still resulted in a hemoglobin level of 0.3 (95% CI, 0.04-0.5) g/dL higher

  10. Between a Map and a Data Rod

    Science.gov (United States)

    Teng, W. L.; Rui, H.; Strub, R. F.; Vollmer, B.

    2015-12-01

    A "Digital Divide" has long stood between how NASA and other satellite-derived data are typically archived (time-step arrays or "maps") and how hydrology and other point-time series oriented communities prefer to access those data. In essence, the desired method of data access is orthogonal to the way the data are archived. Our approach to bridging the Divide is part of a larger NASA-supported "data rods" project to enhance access to and use of NASA and other data by the Consortium of Universities for the Advancement of Hydrologic Science, Inc. (CUAHSI) Hydrologic Information System (HIS) and the larger hydrology community. Our main objective was to determine a way to reorganize data that is optimal for these communities. Two related objectives were to optimally reorganize data in a way that (1) is operational and fits in and leverages the existing Goddard Earth Sciences Data and Information Services Center (GES DISC) operational environment and (2) addresses the scaling up of data sets available as time series from those archived at the GES DISC to potentially include those from other Earth Observing System Data and Information System (EOSDIS) data archives. Through several prototype efforts and lessons learned, we arrived at a non-database solution that satisfied our objectives/constraints. We describe, in this presentation, how we implemented the operational production of pre-generated data rods and, considering the tradeoffs between length of time series (or number of time steps), resources needed, and performance, how we implemented the operational production of on-the-fly ("virtual") data rods. For the virtual data rods, we leveraged a number of existing resources, including the NASA Giovanni Cache and NetCDF Operators (NCO) and used data cubes processed in parallel. Our current benchmark performance for virtual generation of data rods is about a year's worth of time series for hourly data (~9,000 time steps) in ~90 seconds. Our approach is a specific

  11. Between a Map and a Data Rod

    Science.gov (United States)

    Teng, William; Rui, Hualan; Strub, Richard; Vollmer, Bruce

    2015-01-01

    A Digital Divide has long stood between how NASA and other satellite-derived data are typically archived (time-step arrays or maps) and how hydrology and other point-time series oriented communities prefer to access those data. In essence, the desired method of data access is orthogonal to the way the data are archived. Our approach to bridging the Divide is part of a larger NASA-supported data rods project to enhance access to and use of NASA and other data by the Consortium of Universities for the Advancement of Hydrologic Science, Inc. (CUAHSI) Hydrologic Information System (HIS) and the larger hydrology community. Our main objective was to determine a way to reorganize data that is optimal for these communities. Two related objectives were to optimally reorganize data in a way that (1) is operational and fits in and leverages the existing Goddard Earth Sciences Data and Information Services Center (GES DISC) operational environment and (2) addresses the scaling up of data sets available as time series from those archived at the GES DISC to potentially include those from other Earth Observing System Data and Information System (EOSDIS) data archives. Through several prototype efforts and lessons learned, we arrived at a non-database solution that satisfied our objectivesconstraints. We describe, in this presentation, how we implemented the operational production of pre-generated data rods and, considering the tradeoffs between length of time series (or number of time steps), resources needed, and performance, how we implemented the operational production of on-the-fly (virtual) data rods. For the virtual data rods, we leveraged a number of existing resources, including the NASA Giovanni Cache and NetCDF Operators (NCO) and used data cubes processed in parallel. Our current benchmark performance for virtual generation of data rods is about a years worth of time series for hourly data (9,000 time steps) in 90 seconds. Our approach is a specific implementation of

  12. Simultaneous patch-clamping and calcium imaging in developing dendrites.

    Science.gov (United States)

    Kleindienst, Thomas; Lohmann, Christian

    2014-03-01

    Calcium imaging has been used extensively to explore the role of action potential (AP) firing in the development of neuronal structure and synaptic function because increases in intracellular calcium ([Ca(2+)]i) reliably and, within a certain range, linearly reflect neuronal spiking activity. Patterns of APs in individual cells can be deduced from calcium recordings, which have typically been performed at the level of cell bodies. However, neurons are particularly susceptible to phototoxicity when they are illuminated at the soma. Furthermore, for some imaging experiments (e.g., those that address the interactions between dendrites and axons during synapse formation), the cell body of a given neuron may simply not be in the field of view. In these situations, it would be helpful to determine the spiking patterns of a neuron from the calcium activity in its subcellular compartments such as stretches of dendrites or axons. Here, we describe an approach for determining the relationship between AP firing and dendritic calcium transients by simultaneously imaging calcium transients in small dendritic stretches of hippocampal pyramidal neurons in slice cultures from neonatal rats and recording spiking activity with whole-cell patch-clamp recordings in these neurons. These experiments allow us to correlate the electrophysiological spiking pattern with the accompanying changes in the calcium concentration in individual dendritic segments.

  13. Non-Hookean statistical mechanics of clamped graphene ribbons

    Science.gov (United States)

    Bowick, Mark J.; Košmrlj, Andrej; Nelson, David R.; Sknepnek, Rastko

    2017-03-01

    Thermally fluctuating sheets and ribbons provide an intriguing forum in which to investigate strong violations of Hooke's Law: Large distance elastic parameters are in fact not constant but instead depend on the macroscopic dimensions. Inspired by recent experiments on free-standing graphene cantilevers, we combine the statistical mechanics of thin elastic plates and large-scale numerical simulations to investigate the thermal renormalization of the bending rigidity of graphene ribbons clamped at one end. For ribbons of dimensions W ×L (with L ≥W ), the macroscopic bending rigidity κR determined from cantilever deformations is independent of the width when W ℓth , however, this thermally renormalized bending rigidity begins to systematically increase, in agreement with the scaling theory, although in our simulations we were not quite able to reach the system sizes necessary to determine the fully developed power law dependence on W . When the ribbon length L >ℓp , where ℓp is the W -dependent thermally renormalized ribbon persistence length, we observe a scaling collapse and the beginnings of large scale random walk behavior.

  14. Umbilical Cord Milking Versus Delayed Cord Clamping in Preterm Infants.

    Science.gov (United States)

    Katheria, Anup C; Truong, Giang; Cousins, Larry; Oshiro, Bryan; Finer, Neil N

    2015-07-01

    Delayed cord clamping (DCC) is recommended for premature infants to improve blood volume. Most preterm infants are born by cesarean delivery (CD), and placental transfusion may be less effective than in vaginal delivery (VD). We sought to determine whether infants umbilical cord milking (UCM) have higher measures of systemic blood flow than infants who undergo DCC. This was a 2-center trial. Infants delivered by CD were randomly assigned to undergo UCM or DCC. Infants delivered by VD were also randomly assigned separately. UCM (4 strippings) or DCC (45-60 seconds) were performed. Continuous hemodynamic measurements and echocardiography were done at site 1. A total of 197 infants were enrolled (mean gestational age 28 ± 2 weeks). Of the 154 infants delivered by CD, 75 were assigned to UCM and 79 to DCC. Of the infants delivered by CD, neonates randomly assigned to UCM had higher superior vena cava flow and right ventricular output in the first 12 hours of life. Neonates undergoing UCM also had higher hemoglobin, delivery room temperature, blood pressure over the first 15 hours, and urine output in the first 24 hours of life. There were no differences for the 43 infants delivered by VD. This is the first randomized controlled trial demonstrating higher systemic blood flow with UCM in preterm neonates compared with DCC. UCM may be a more efficient technique to improve blood volume in premature infants delivered by CD. Copyright © 2015 by the American Academy of Pediatrics.

  15. Determination of the rod-wire transition length in colloidal indium phosphide quantum rods.

    Science.gov (United States)

    Wang, Fudong; Buhro, William E

    2007-11-21

    Colloidal InP quantum rods (QRs) having controlled diameters and lengths are grown by the solution-liquid-solid method, from Bi nanoparticles in the presence of hexadecylamine and other conventional quantum dot surfactants. These quantum rods show band-edge photoluminescence after HF photochemical etching. Photoluminescence efficiency is further enhanced after the Bi tips are selectively removed from the QRs by oleic acid etching. The QRs are anisotropically 3D confined, the nature of which is compared to the corresponding isotropic 3D confinement in quantum dots and 2D confinement in quantum wires. The 3D-2D rod-wire transition length is experimentally determined to be 25 nm, which is about 2 times the bulk InP exciton Bohr radius (of approximately 11 nm).

  16. Establishing baseline rod electroretinogram values in achromatopsia and cone dystrophy.

    Science.gov (United States)

    Wang, Isaac; Khan, Naheed W; Branham, Kari; Wissinger, B; Kohl, Susanne; Heckenlively, J R

    2012-12-01

    To establish the normal range of values for rod-isolated b-wave amplitudes in achromatopsia and cone dystrophies. We reviewed charts of 112 patients with various types of cone dystrophy, and compared their standardized electroretinographic rod b-wave amplitudes with age-matched normal controls. Twenty-six patients had known mutations in achromatopsia and cone dystrophy genes, while 53 were characterized by their inheritance pattern since they had yet to have their gene identified. Visual acuity information and scotomata were documented. We found that patients with achromatopsia and cone dystrophy had rod b-wave amplitudes that were significantly lower than age-matched controls, but found no evidence of rod amplitude progression nor loss of peripheral visual fields in the study group. We found that cone dystrophy patients of all types had depressed rod-isolated ERGs across the board. If typical diagnostic criteria are used, these patients might be considered to have "abnormal" rod-isolated electroretinographic values, and might be called "cone-rod dystrophy", even though the waveforms are stable for years. Patients with cone-rod dysfunction patterns on ERG can be better understood by also performing kinetic (Goldmann) visual fields, which will help to distinguish cone dystrophies from progressive cone-rod dystrophies by central scotomata size and progression over time in many forms of cone-rod dystrophy.

  17. Sucker-rod pumping handbook production engineering fundamentals and long-stroke rod pumping

    CERN Document Server

    Takacs, Gabor

    2015-01-01

    Sucker-Rod Pumping Handbook presents the latest information on the most common form of production enhancement in today's oil industry, making up roughly two-thirds of the producing oilwell operations in the world. The book begins with an introduction to the main features of sucker rod pumping and an explanation and comparison of lift methods. It goes on to provide the technical and practical knowledge needed to introduce the new and practicing production engineer and operator to the equipment, technology, and applications required to maintain optimum operating conditions.

  18. 压紧销头部成形级进模设计%Development of progressive die for the head of pressing rod

    Institute of Scientific and Technical Information of China (English)

    都超平; 恽达明

    2013-01-01

    The design of a multi-position progressive die for the upsetting and forming of the head of a pressing rod was presented. A die sleeve component structure was designed for the conveying of the rod. By applying the inclined fitting of die frame and core and their relative replacement, the placement, clamping and conveying of the rod, as well as the rod position control and striping can be implemented.%分析了压紧销制件的成形工艺,针对压紧销头部的镦粗、成形设计了一副多工位级进模,在杆状工序件的传送方面,设计了一种模套组件结构,利用模框和模芯的斜面配合和相对位移,既方便放入制件毛坯,实现工序件夹持、输送,又可以与其他装置一起控制工序件的上下位置以及制件的推出,从而解决了杆状制件采用级进模进行成形的难题。

  19. Committee Opinion No. 684 Summary: Delayed Umbilical Cord Clamping After Birth.

    Science.gov (United States)

    2017-01-01

    Delayed umbilical cord clamping appears to be beneficial for term and preterm infants. In term infants, delayed umbilical cord clamping increases hemoglobin levels at birth and improves iron stores in the first several months of life, which may have a favorable effect on developmental outcomes. There is a small increase in jaundice that requires phototherapy in this group of infants. Consequently, health care providers adopting delayed umbilical cord clamping in term infants should ensure that mechanisms are in place to monitor for and treat neonatal jaundice. In preterm infants, delayed umbilical cord clamping is associated with significant neonatal benefits, including improved transitional circulation, better establishment of red blood cell volume, decreased need for blood transfusion, and lower incidence of necrotizing enterocolitis and intraventricular hemorrhage. Delayed umbilical cord clamping was not associated with an increased risk of postpartum hemorrhage or increased blood loss at delivery, nor was it associated with a difference in postpartum hemoglobin levels or the need for blood transfusion. Given the benefits to most newborns and concordant with other professional organizations, the American College of Obstetricians and Gynecologists now recommends a delay in umbilical cord clamping in vigorous term and preterm infants for at least 30-60 seconds after birth. The ability to provide delayed umbilical cord clamping may vary among institutions and settings; decisions in those circumstances are best made by the team caring for the mother-infant dyad.

  20. Committee Opinion No.543: Timing of umbilical cord clamping after birth.

    Science.gov (United States)

    2012-12-01

    The optimal timing for clamping the umbilical cord after birth has been a subject of controversy and debate. Although many randomized controlled trials in term and preterm infants have evaluated the benefits of delayed umbilical cord clamping versus immediate umbilical cord clamping, the ideal timing for cord clamping has yet to be established. Several systematic reviews have suggested that clamping the umbilical cord in all births should be delayed for at least 30-60 seconds, with the infant maintained at or below the level of the placenta because of the associated neonatal benefits, including increased blood volume, reduced need for blood transfusion, decreased incidence of intracranial hemorrhage in preterm infants, and lower frequency of iron deficiency anemia in term infants. Evidence exists to support delayed umbilical cord clamping in preterm infants, when feasible. The single most important clinical benefit for preterm infants is the possibility for a nearly 50% reduction in intraventricular hemorrhage. However, currently, evidence is insufficient to confirm or refute the potential for benefits from delayed umbilical cord clamping in term infants, especially in settings with rich resources.

  1. Blood gas values in clamped and unclamped umbilical cord at birth.

    Science.gov (United States)

    Di Tommaso, Mariarosaria; Seravalli, Viola; Martini, Irene; La Torre, Pasquale; Dani, Carlo

    2014-09-01

    To determine the reliability of the cord blood gas analysis on the unclamped cord compared to the standard technique of sampling on double clamped cord. Prospective observational study conducted on 46 singleton neonates vaginally delivered at term. Matched pairs of umbilical artery and vein blood samples were collected from unclamped cord within 90s after birth and from the same cord after clamping, with the clamping occurring immediately after the first blood collection. A blood gas analysis was performed on each collected sample. Arterial and venous blood samples were analyzed for pH, PO2, pCO2, SaO2, hemoglobin concentration (ctHb) and base excess (BE). The values were compared between the two groups (clamped vs unclamped) using a Wilcoxon test. No significant difference was found in pH, PO2, pCO2, SaO2 and ctHb values on arterial blood between unclamped and clamped cord. The only significant difference was related to BE (pblood, the values of pH, PO2, pCO2 were comparable between unclamped and clamped cord, while the values of SaO2, ctHb and BE were significantly different (pblood gas parameters and in the main venous blood gas parameters between unclamped and clamped cord. Sampling of cord blood for gas analysis may be performed on the unclamped cord right after birth without reducing the accuracy of the analysis. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Immunologic and infectious consequences of immediate versus delayed umbilical cord clamping in premature infants: a prospective, randomized, controlled study.

    Science.gov (United States)

    Kugelman, Amir; Borenstein-Levin, Liron; Kessel, Aharon; Riskin, Arieh; Toubi, Elias; Bader, David

    2009-01-01

    To evaluate the immunologic and infectious consequences of delayed versus immediate cord clamping in premature infants (cord clamping (ICC) at 5-10 s and 30 infants to delayed cord clamping (DCC), at 30-45 s (14 and 15 infants in each group were cord clamping did not affect the immunologic or the infectious status of infants born at <35 weeks during the neonatal period.

  3. Ground Wars

    DEFF Research Database (Denmark)

    Nielsen, Rasmus Kleis

    Political campaigns today are won or lost in the so-called ground war--the strategic deployment of teams of staffers, volunteers, and paid part-timers who work the phones and canvass block by block, house by house, voter by voter. Ground Wars provides an in-depth ethnographic portrait of two...... infrastructures that utilize large databases with detailed individual-level information for targeting voters, and armies of dedicated volunteers and paid part-timers. Nielsen challenges the notion that political communication in America must be tightly scripted, controlled, and conducted by a select coterie...... of professionals. Yet he also quashes the romantic idea that canvassing is a purer form of grassroots politics. In today's political ground wars, Nielsen demonstrates, even the most ordinary-seeming volunteer knocking at your door is backed up by high-tech targeting technologies and party expertise. Ground Wars...

  4. Visual transduction in human rod photoreceptors.

    Science.gov (United States)

    Kraft, T W; Schneeweis, D M; Schnapf, J L

    1993-05-01

    1. Photocurrents were recorded with suction electrodes from rod photoreceptors of seven humans. 2. Brief flashes of light evoked transient outward currents of up to 20 pA. With increasing light intensity the peak response amplitude increased along an exponential saturation function. A half-saturating peak response was evoked by approximately sixty-five photoisomerizations. 3. Responses to brief dim flashes rose to a peak in about 200 ms. The waveform was roughly like the impulse response of a series of four to five low-pass filters. 4. The rising phases of the responses to flashes of increasing strength were found to fit with a biochemical model of phototransduction with an 'effective delay time' and 'characteristic time' of about 2 and 800 ms, respectively. 5. Spectral sensitivities were obtained over a wavelength range from 380 to 760 nm. The action spectrum, which peaked at 495 nm, followed the template described for photoreceptors in the macaque retina. Variation between rods in the position of the spectrum on the wavelength axis was small. 6. The scotopic luminosity function derived from human psychophysical experiments was found to agree well with the measured rod action spectrum after adjustments were made for lens absorption and photopigment self-screening in the intact eye. 7. Responses to steps of light rose monotonically to a maintained level, showing little or no relaxation. Nevertheless, the relationship between light intensity and steady-state response amplitude was shallower than that expected from simple response saturation. This is consistent with an adaptation mechanism acting on a rapid time scale. 8. Flash sensitivity fell with increasing intensities of background light according to Weber's law. Sensitivity was reduced twofold by lights evoking about 120 photoisomerizations per second. Background lights decreased the time to peak and the integration time of the flash response by up to 20%.

  5. Transient waves in finite viscoelastic rods

    Energy Technology Data Exchange (ETDEWEB)

    Mainardi, F. (Bologna Univ. (Italy). Ist. di Fisica); Nervosi, R. (Bologna Univ. (Italy))

    1980-11-29

    A method based on the Laplace transform is presented to compute wave-front expansions for transient waves in finite viscoelastic rods using the creep or the relaxation representation. The response is related to the basic solution of the semi-infinite problem, for which a series expansion is obtained by a recursive procedure. The convergence is guaranteed in any space-time domain if the material functions are entirely of exponential type. However, for numerical computation an acceleration of convergence is required and the Pade approximants turn out to be successful as shown by some examples.

  6. Rod-like nano-light harvester.

    Science.gov (United States)

    Ling, Jun; Zheng, Zhicheng; Köhler, Anna; Müller, Axel H E

    2014-01-01

    Imitating the natural "energy cascade" architecture, we present a single-molecular rod-like nano-light harvester (NLH) based on a cylindrical polymer brush. Block copolymer side chains carrying (9,9-diethylfluoren-2-yl)methyl methacrylate units as light absorbing antennae (energy donors) are tethered to a linear polymer backbone containing 9-anthracenemethyl methacrylate units as emitting groups (energy acceptors). These NLHs exhibit very efficient energy absorption and transfer. Moreover, we manipulate the energy transfer by tuning the donor-acceptor distance.

  7. Locally periodic Timoshenko rod: experiment and theory.

    Science.gov (United States)

    Díaz-de-Anda, A; Pimentel, A; Flores, J; Morales, A; Gutiérrez, L; Méndez-Sánchez, R A

    2005-05-01

    The flexural vibrations of a locally periodic rod, which consists of N unit cells, are discussed both from the experimental and theoretical points of view. Timoshenko's beam theory and the transfer matrix method are used to calculate the normal-mode frequencies and amplitudes. The theoretical values are then compared with the experimental ones, which are obtained using an electromagnetic acoustic transducer (EMAT). Good agreement between the numerical results and the experimental measurements is obtained. It is shown that as N grows, a band spectrum emerges.

  8. 4-rod RFQ linac for ion implantation

    Energy Technology Data Exchange (ETDEWEB)

    Fujisawa, Hiroshi; Hamamoto, Nariaki; Inouchi, Yutaka [Nisshin Electric Co. Ltd., Kyoto (Japan)

    1997-03-01

    A 34 MHz 4-rod RFQ linac system has been upgraded in both its rf power efficiency and beam intensity. The linac is able to accelerate in cw operation 0.83 mA of a B{sup +} ion beam from 0.03 to 0.91 MeV with transmission of 61 %. The rf power fed to the RFQ is 29 kW. The unloaded Q-value of the RFQ has been improved approximately 61 % to 5400 by copper-plating stainless steel cooling pipes in the RFQ cavity. (author)

  9. High-yield production of hydrophobins RodA and RodB from Aspergillus fumigatus in Pichia pastoris.

    Science.gov (United States)

    Pedersen, Mona Højgaard; Borodina, Irina; Moresco, Jacob Lange; Svendsen, Winnie Edith; Frisvad, Jens Christian; Søndergaard, Ib

    2011-06-01

    Hydrophobins are small fungal proteins with amphipatic properties and the ability to self-assemble on a hydrophobic/hydrophilic interface; thus, many technical applications for hydrophobins have been suggested. The pathogenic fungus Aspergillus fumigatus expresses the hydrophobins RodA and RodB on the surface of its conidia. RodA is known to be of importance to the pathogenesis of the fungus, while the biological role of RodB is currently unknown. Here, we report the successful expression of both hydrophobins in Pichia pastoris and present fed-batch fermentation yields of 200-300 mg/l fermentation broth. Protein bands of expected sizes were detected by SDS-PAGE and western blotting, and the identity was further confirmed by tandem mass spectrometry. Both proteins were purified using his-affinity chromatography, and the high level of purity was verified by silver-stained SDS-PAGE. Recombinant RodA as well as rRodB were able to convert a glass surface from hydrophilic to hydrophobic similar to native RodA, but only rRodB was able to decrease the hydrophobicity of a Teflon-like surface to the same extent as native RodA, while rRodA showed this ability to a lesser extent. Recombinant RodA and native RodA showed a similar ability to emulsify air in water, while recombinant RodB could also emulsify oil in water better than the control protein bovine serum albumin (BSA). This is to our knowledge the first successful expression of hydrophobins from A. fumigatus in a eukaryote host, which makes it possible to further characterize both hydrophobins. Furthermore, the expression strategy and fed-batch production using P. pastoris may be transferred to hydrophobins from other species.

  10. Analysis of the role of PCNA-DNA contacts during clamp loading

    Directory of Open Access Journals (Sweden)

    Goedken Eric R

    2010-01-01

    Full Text Available Abstract Background Sliding clamps, such as Proliferating Cell Nuclear Antigen (PCNA in eukaryotes, are ring-shaped protein complexes that encircle DNA and enable highly processive DNA replication by serving as docking sites for DNA polymerases. In an ATP-dependent reaction, clamp loader complexes, such as the Replication Factor-C (RFC complex in eukaryotes, open the clamp and load it around primer-template DNA. Results We built a model of RFC bound to PCNA and DNA based on existing crystal structures of clamp loaders. This model suggests that DNA would enter the clamp at an angle during clamp loading, thereby interacting with positively charged residues in the center of PCNA. We show that simultaneous mutation of Lys 20, Lys 77, Arg 80, and Arg 149, which interact with DNA in the RFC-PCNA-DNA model, compromises the ability of yeast PCNA to stimulate the DNA-dependent ATPase activity of RFC when the DNA is long enough to extend through the clamp. Fluorescence anisotropy binding experiments show that the inability of the mutant clamp proteins to stimulate RFC ATPase activity is likely caused by reduction in the affinity of the RFC-PCNA complex for DNA. We obtained several crystal forms of yeast PCNA-DNA complexes, measuring X-ray diffraction data to 3.0 Å resolution for one such complex. The resulting electron density maps show that DNA is bound in a tilted orientation relative to PCNA, but makes different contacts than those implicated in clamp loading. Because of apparent partial disorder in the DNA, we restricted refinement of the DNA to a rigid body model. This result contrasts with previous analysis of a bacterial clamp bound to DNA, where the DNA was well resolved. Conclusion Mutational analysis of PCNA suggests that positively charged residues in the center of the clamp create a binding surface that makes contact with DNA. Disruption of this positive surface, which had not previously been implicated in clamp loading function, reduces RFC

  11. A Central Swivel Point in the RFC Clamp Loader Controls PCNA Opening and Loading on DNA

    OpenAIRE

    Sakato, Miho; O’Donnell, Mike; Hingorani, Manju M.

    2011-01-01

    Replication Factor C (RFC) is a 5-subunit complex that loads PCNA clamps onto primer-template DNA (ptDNA) during replication. RFC subunits belong to the AAA+ superfamily, and their ATPase activity drives interactions between the clamp loader, clamp, and ptDNA, leading to topologically linked PCNA•ptDNA. We report the kinetics of transient events in S. cerevisiae RFC catalyzed PCNA loading, including ATP-induced RFC activation, PCNA opening, ptDNA binding, ATP hydrolysis, PCNA closing and PCNA...

  12. Characterization of potassium channel modulators with QPatch automated patch-clamp technology: system characteristics and performance

    DEFF Research Database (Denmark)

    Kutchinsky, Jonatan; Friis, Søren; Asmild, Margit

    2003-01-01

    Planar silicon chips with 1-2-microm etched holes (average resistance: 2.04 +/- 0.02 MOmega in physiological buffer, n = 274) have been developed for patch-clamp recordings of whole-cell currents from cells in suspension. An automated 16-channel parallel screening system, QPatch 16, has been...... developed using this technology. A single-channel prototype of the QPatch system was used for validation of the patch-clamp chip technology. We present here data on the quality of patch-clamp recordings and from actual drug screening studies of human potassium channels expressed in cultured cell lines...

  13. Modelling the clamping force distribution among chips in press-pack IGBTs using the finite element method

    DEFF Research Database (Denmark)

    Hasmasan, Adrian Augustin; Busca, Christian; Teodorescu, Remus

    2012-01-01

    In this paper, a FEM (finite element method) based mechanical model for PP (press-pack) IGBTs (insulated gate bipolar transistors) is presented, which can be used to calculate the clamping force distribution among chips under various clamping conditions. The clamping force is an important paramet...

  14. Stirring with ghost rods in a lid-driven cavity

    Science.gov (United States)

    Kumar, Pankaj; Chen, Jie; Stremler, Mark

    2009-11-01

    It has shown that passive fluid particles moving on periodic orbits can be used to `stir' a viscous fluid in a two-dimensional lid-driven cavity that exhibits a figure-eight flow pattern (Stremler & Chen 2007). Fluid motion in the vicinity of these particles produces ``ghost rod'' structures that behave like semi-permeable rods in the flow. Since these ghost rods are present due to the system dynamics, perturbations in the boundary conditions lead to variations in the existence and structure of the ghost rods. We discuss these variations and assess the role of ghost rods in mixing over a range of operating conditions for this system. The results suggest that ghost rods can play an important role in mixing for other counter-rotating flows.

  15. Vibration of the Package of Rods Linked by Spacer Grids

    Science.gov (United States)

    Zeman, V.; Hlaváč, Z.

    This paper deals with modelling and vibration analysis of the large package of identical parallel rods which are linked by transverse springs (spacer grids) placed on several level spacings. The vibration of rods is caused by the support plate motion. The rod discretization by FEM is based on Rayleigh beam theory. With respect to cyclic and central package rod symmetry, the system is decomposed to identical revolved rod segments. The modal synthesis method with condensation of the rod segments is used for modelling and determination of steady forced vibration of the whole system. The presented method is the first step to modelling of the nuclear fuel assembly vibration caused by kinematical excitation determined by motion of the support plates which are part of the reactor core.

  16. Metallography and Microanalysis of Qinshan PhaseⅠ NPP Spent Fuel Rods

    Institute of Scientific and Technical Information of China (English)

    QIAN; Jin; BIAN; Wei; GUO; Li-na; GUO; Yi-fan; CHU; Feng-min; LIANG; Zheng-qiang

    2015-01-01

    Qinshan PhaseⅠNPP is a first domestic commercial PWR and its fuel rods and fuel assembly were designed and manufactured by China.In order to assess the irradiation properties of the fuel rods,8spent fuel rods which were drew out from 3fuel assemblies were transferred to CIAE hot cells for post irradiation examination(PIE)in 2014.The cladding material of the fuel

  17. Synthesis of homochiral tris-indanyl molecular rods

    DEFF Research Database (Denmark)

    Kjeldsen, Niels Due; Funder, Erik Daa; Gothelf, Kurt Vesterager

    2014-01-01

    Homochiral tris-indanyl molecular rods designed for supramolecular surface self-assembly were synthesized. The chiral indanol moiety was constructed via a Ti-mediated alkyne trimerization. Further manipulations resulted in a homochiral indanol monomer. This was employed as the precursor...... for successive Sonogashira and Ohira-Bestman reactions towards the homochiral tris-indanyl molecular rods. The molecular rods will be applied for scanning tunnelling microscopy studies of their surface self-assembly and chirality....

  18. Do rod signals control stimulus field prevalence in binocular rivalry?

    Science.gov (United States)

    Young, R S; Young, G A

    1979-02-01

    We tested the hypothesis that rod signals mediate the effect of luminance on field prevalence in binocular rivalry. Results show that (1) field prevalence saturates at a luminance that is less than 0.001 that of the value reported for rod saturation, (2) the spectral sensitivity inferred from the prevalence-luminance relationship is not scotopic, and (3) the prevalence-luminance relationship does not behave univariantly under all chromatic conditions. We conclude that rod signals alone do not control field prevalence.

  19. Rigid rod spaced fullerene as building block for nanoclusters

    Indian Academy of Sciences (India)

    Pallikara K Sudeep; James P Varkey; K George Thomas; Manappurathu V George; Prashant V Kamat

    2003-10-01

    By using phenylacetylene based rigid-rod linkers (PhA), we have successfully synthesized two fullerene derivatives, C60-PhA and C60-PhA-C60. The absorption spectral features of C60, as well as that of the phenylacetylene moiety are retained in the monomeric forms of these fullerene derivatives, ruling out the possibility of any strong interaction between the two chromophores in the ground state. Both the fullerene derivatives form optically transparent clusters, absorbing in the UV-Vis region; this clustering leads to a significant increase in their molar extinction coefficients. TEM characterization of the C60-PhA showed large spherical clusters, with sizes ranging from 150-350 nm, while an elongated wire-type structure was observed for the bisfullerene derivative (C60-PhA-C60). AFM section analysis studies of isolated nanoclusters of C60-PhA-C60, deposited on mica, indicate that smaller clusters associate to form larger nanostructures.

  20. Static and dynamic stability results for a class of three-dimensional configurations of Kirchhoff elastic rods

    KAUST Repository

    Majumdar, Apala

    2013-06-01

    We analyze the dynamical stability of a naturally straight, inextensible and unshearable elastic rod, under tension and controlled end rotation, within the Kirchhoff model in three dimensions. The cases of clamped boundary conditions and isoperimetric constraints are treated separately. We obtain explicit criteria for the static stability of arbitrary extrema of a general quadratic strain energy. We exploit the equivalence between the total energy and a suitably defined norm to prove that local minimizers of the strain energy, under explicit hypotheses, are stable in the dynamic sense due to Liapounov. We also extend our analysis to damped systems to show that static equilibria are dynamically stable in the Liapounov sense, in the presence of a suitably defined local drag force. © 2013 Elsevier B.V. All rights reserved.

  1. Vortex patterns in a superconducting-ferromagnetic rod

    Energy Technology Data Exchange (ETDEWEB)

    Romaguera, Antonio R. de C, E-mail: antonio.romaguera@df.ufrpe.b [Departamento de Fi' sica, Universidade Federal Rural de Pernambuco, 52171-900 Recife, Pernambuco (Brazil); Doria, Mauro M. [Departamento de Fi' sica dos Solidos, Universidade Federal do Rio de Janeiro, 21941-972 Rio de Janeiro (Brazil); Peeters, Francois M. [Departement Fysica, Universiteit Antwerpen, Groenenborgerlaan 171, B-2020 Antwerpen (Belgium)

    2010-10-01

    A superconducting rod with a magnetic moment on top develops vortices obtained here through 3D calculations of the Ginzburg-Landau theory. The inhomogeneity of the applied field brings new properties to the vortex patterns that vary according to the rod thickness. We find that for thin rods (disks) the vortex patterns are similar to those obtained in presence of a homogeneous magnetic field instead because they consist of giant vortex states. For thick rods novel patterns are obtained as vortices are curve lines in space that exit through the lateral surface.

  2. Biophysical mechanism of transient retinal phototropism in rod photoreceptors

    Science.gov (United States)

    Zhao, Xiaohui; Thapa, Damber; Wang, Benquan; Gai, Shaoyan; Yao, Xincheng

    2016-03-01

    Oblique light stimulation evoked transient retinal phototropism (TRP) has been recently detected in frog and mouse retinas. High resolution microscopy of freshly isolated retinas indicated that the TRP is predominated by rod photoreceptors. Comparative confocal microscopy and optical coherence tomography (OCT) revealed that the TRP predominantly occurred from the photoreceptor outer segment (OS). However, biophysical mechanism of rod OS change is still unknown. In this study, frog retinal slices, which open a cross section of retinal photoreceptor and other functional layers, were used to test the effect of light stimulation on rod OS. Near infrared light microscopy was employed to monitor photoreceptor changes in retinal slices stimulated by a rectangular-shaped visible light flash. Rapid rod OS length change was observed after the stimulation delivery. The magnitude and direction of the rod OS change varied with the position of the rods within the stimulated area. In the center of stimulated region the length of the rod OS shrunk, while in the peripheral region the rod OS tip swung towards center region in the plane perpendicular to the incident stimulus light. Our experimental result and theoretical analysis suggest that the observed TRP may reflect unbalanced disc-shape change due to localized pigment bleaching. Further investigation is required to understand biochemical mechanism of the observed rod OS kinetics. Better study of the TRP may provide a noninvasive biomarker to enable early detection of age-related macular degeneration (AMD) and other diseases that are known to produce retinal photoreceptor dysfunctions.

  3. Grey Rod Test in HANARO Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Choo, K. N.; Kim, B. G.; Kang, Y. H. (and others)

    2008-08-15

    Westinghouse/KAERI/KNF agreed to perform an irradiation test in the HANARO reactor to obtain irradiation data on the new grey rods that will be part of an AP1000 system. As a preliminary test, two samples containing pure Ag (Reference) and Ag-In-Cd materials provided by Westinghouse Electric Company (WEC) were inserted in a KNF irradiation capsule of 07M-13N. The specimens were irradiated for 95.19days (4 cycles) in the CT test hole of the HANARO of a 30MW thermal output to have a fast neutron fluence of 1.11x10{sup 21}(n/cm{sup 2}) (E>1.0MeV). This report provides all the test conditions and data obtained during the irradiation test of the grey rods in HANARO requested by Westinghouse. The test was prepared according to the meeting minutes (June 26, 2007) and the on-going subject test was stopped midway by the request of Westinghouse.

  4. Plastic Guidance Fins for Long Rod Projectiles .

    Directory of Open Access Journals (Sweden)

    Mark L. Bundy

    1997-10-01

    Full Text Available Projectile tail fins on long rod kinetic energy (KE penetrators serve the same purpose as fletchings (feathers on an arrow, namely, they help align the projectile axis with its velocity vector. This reduces the projectile's yaw and hence reduces its aerodynamic drag. In addition, a low yaw angle at target impact helps to maximise the projectile's target penetration. It is typical for projectiles to exit the gun muzzle and enter free flight at some ndn-zero yaw angle. Aerodynamic forces acting on yawed tail fins create a stabilising torque about the projectile's centre of gravity (CG. This torque can be increased by making the fin material lighter. Most conventional long rod penetrators fired from high performance guns have tail fins made from aluminium. However, aluminium can undergo catastrophic oxidation (rapid burning in-bore. Coating aluminium with Al/sub 2/O/sub 3/ {hardcoat prevents ignition of the substrate, provided solid propellant grain impacts do not chip the brittle hardcoat off the surface. Plastic is lighter than aluminium and less exothermic when oxidized. Therefore, other factors aside, it is conceivable that plastic fins could increase projectile stability while incurring less thermal erosion than aluminium. However, thermal loads are not the only concern when considering plastic as an alternative tail fin material. The mechanical strength of plastic is also a critical factor. This paper discusses some of the successes and failures of plastic fins, at least relatively thin fins, for use as KE stabilisers.

  5. Rolls-Royce digital Rod Control System

    Energy Technology Data Exchange (ETDEWEB)

    Pouillot, M. [Rolls-Royce Civil Nuclear SAS (France)

    2010-07-01

    Full text of publication follows: Rolls-Royce has developed a new generation of Rod Control System, based on 40 years of experience. The fifth-generation Rod Control System (RCS) from Rolls-Royce offers a reliable, modular design with adaptability to your preferred platform, for modernization projects or new reactors. Flexible implementation provides the option for you to keep existing cabinets, which permits you to optimize installation approach. Main features for the power part: - Control Rod Drive Mechanism (CRDM) type: 3-coil. - Independent control of each sub-bank. - Each sub-bank is controlled by a cycler unit and 3 identical power racks, each including 4 identical power modules and a common power-supply module. - Coil-per-coil digital control: each power module embeds power-conversion, current-control, and current-monitoring functions for one coil. Control and monitoring are carried out by separate electronics in the module. Current is digitized and fully monitored by means of min-max templates. - A double-hold function is included: a power module assigned to a gripper will activate its coil if a fault risking to cause a reactor trip occurs. - Power modules are standardized, hot-pluggable and self-configured: a power module includes a set of parameters for each type of coil SG, MG, LC. The module recognizes the rack it is plugged in, and chooses automatically parameters to be used. Main benefits: - Reduced operational, maintenance, training, and inventory costs: standardization of power modules and integration of control and monitoring on the same PC-card lead to a drastic reduction of spare part types, and simplification of the system. - Easy maintenance: - Replacement of a power module solves nearly all failures due to current control or monitoring for a coil. It is done instantly thanks to hot-plug capability. - On the front plate of power-modules, LEDs provide useful information for diagnostic: current setpoint from cycler, output current bar

  6. Electrosurgical bipolar vessel sealing versus conventional clamping and suturing for total abdominal hysterectomy: a randomized trial.

    NARCIS (Netherlands)

    Lakeman, M.; Kruitwagen, R.F.P.M.; Vos, M.C.; Roovers, J.P.

    2008-01-01

    STUDY OBJECTIVE: To compare the effects of bipolar vessel sealing versus conventional clamping and suturing in women undergoing total abdominal hysterectomy. DESIGN: A randomized controlled trial was performed. Patients were randomized to vessel sealing or conventional surgery. Postoperative pain wa

  7. Common voltage eliminating of SVM diode clamping three-level inverter connected to grid

    DEFF Research Database (Denmark)

    Guo, Yougui; Zeng, Ping; Zhu, Jieqiong

    2011-01-01

    A novel method of common voltage eliminating is put forward for SVM diode clamping three-level inverter connected to grid by calculation of common voltage of its various switching states. PLECS is used to model this three-level inverter connected to grid and good results are obtained. First...... analysis of common mode voltage for switching states of diode clamping 3-level inverter is given in detail. Second the common mode voltage eliminating control strategy of SVM is described for diode clamping three-level inverter. Third, PLECS is briefly introduced. Fourth, the modeling of diode clamping...... three-level inverter is presented with PLECS. Finally, a series of simulations are carried out. The simulation results tell us PLECS is a very powerful tool to real power circuits modeling. They have also verified that proposed common mode voltage eliminating control strategy of SVM is feasible...

  8. Renal perfusion with venous blood extends the permissible suprarenal clamp time in abdominal aortic surgery

    National Research Council Canada - National Science Library

    Pichlmaier, Maximilian; Hoy, Ludwig; Wilhelmi, Mathias; Khaladj, Nawid; Haverich, Axel; Teebken, Omke E

    2008-01-01

    ... suprarenal clamping for aortic reconstructive surgery. Renal perfusion was achieved using a roller pump supplied with venous blood from a central venous catheter under medium-level heparinization to feed two perfusion balloon catheters...

  9. Suppression of Spiral Waves by Voltage Clamp Techniques in a Conductance-Based Cardiac Tissue Model

    Institute of Scientific and Technical Information of China (English)

    YU Lian-Chun; MA Jun; ZHANG Guo-Yong; CHEN Yong

    2008-01-01

    A new control method is proposed to control the spatio-temporal dynamics in excitable media, which is described by the Morris-Lecar cells model. It is confirmed that successful suppression of spiral waves can be obtained by spatially clamping the membrane voltage of the excitable cells. The low voltage clamping induces breakup of spiral waves and the fragments are soon absorbed by low voltage obstacles, whereas the high voltage clamping generates travel waves that annihilate spiral waves through collision with them. However, each method has its shortcomings. Furthermore, a two-step method that combines both low and high voltage clamp techniques is then presented as a possible way of out this predicament.

  10. Implementation of a fast 16-Bit dynamic clamp using LabVIEW-RT.

    Science.gov (United States)

    Kullmann, Paul H M; Wheeler, Diek W; Beacom, Joshua; Horn, John P

    2004-01-01

    The dynamic-clamp method provides a powerful electrophysiological tool for creating virtual ionic conductances in living cells and studying their influence on membrane potential. Here we describe G-clamp, a new way to implement a dynamic clamp using the real-time version of the Lab-VIEW programming environment together with a Windows host, an embedded microprocessor that runs a real-time operating system and a multifunction data-acquisition board. The software includes descriptions of a fast voltage-dependent sodium conductance, delayed rectifier, M-type and A-type potassium conductances, and a leak conductance. The system can also read synaptic conductance waveforms from preassembled data files. These virtual conductances can be reliably implemented at speeds LabVIEW should make it relatively easy for others to adapt G-clamp for new experimental applications.

  11. Characterization of control rod worths and fuel rod power peaking factors in the university of Utah TRIGA Mark I reactor

    OpenAIRE

    Alroumi Fawaz; Kim Donghoon; Schow Ryan; Jevremovic Tatjana

    2016-01-01

    Control rod reactivity (worths) for the three control rods and fuel rod power peaking factors in the University of Utah research reactor (100 kW TRIGA Mark I) are characterized using the AGENT code system and the results described in this paper. These values are compared to the MCNP6 and existing experimental measurements. In addition, the eigenvalue, neutron spatial flux distributions and reaction rates are analyzed and discussed. The AGENT code system is ...

  12. Modeling CICR in rat ventricular myocytes: voltage clamp studies

    Directory of Open Access Journals (Sweden)

    Palade Philip T

    2010-11-01

    Full Text Available Abstract Background The past thirty-five years have seen an intense search for the molecular mechanisms underlying calcium-induced calcium-release (CICR in cardiac myocytes, with voltage clamp (VC studies being the leading tool employed. Several VC protocols including lowering of extracellular calcium to affect Ca2+ loading of the sarcoplasmic reticulum (SR, and administration of blockers caffeine and thapsigargin have been utilized to probe the phenomena surrounding SR Ca2+ release. Here, we develop a deterministic mathematical model of a rat ventricular myocyte under VC conditions, to better understand mechanisms underlying the response of an isolated cell to calcium perturbation. Motivation for the study was to pinpoint key control variables influencing CICR and examine the role of CICR in the context of a physiological control system regulating cytosolic Ca2+ concentration ([Ca2+]myo. Methods The cell model consists of an electrical-equivalent model for the cell membrane and a fluid-compartment model describing the flux of ionic species between the extracellular and several intracellular compartments (cell cytosol, SR and the dyadic coupling unit (DCU, in which resides the mechanistic basis of CICR. The DCU is described as a controller-actuator mechanism, internally stabilized by negative feedback control of the unit's two diametrically-opposed Ca2+ channels (trigger-channel and release-channel. It releases Ca2+ flux into the cyto-plasm and is in turn enclosed within a negative feedback loop involving the SERCA pump, regulating[Ca2+]myo. Results Our model reproduces measured VC data published by several laboratories, and generates graded Ca2+ release at high Ca2+ gain in a homeostatically-controlled environment where [Ca2+]myo is precisely regulated. We elucidate the importance of the DCU elements in this process, particularly the role of the ryanodine receptor in controlling SR Ca2+ release, its activation by trigger Ca2+, and its

  13. Patch Clamp: A Powerful Technique for Studying the Mechanism of Acupuncture

    Directory of Open Access Journals (Sweden)

    D. Zhang

    2012-01-01

    Full Text Available Cellular and molecular events can be investigated using electrophysiological techniques. In particular, the patch-clamp method provides detailed information. In addition, the patch-clamp technique has become a powerful method for investigating the mechanisms underlying the effects of acupuncture. In this paper, recent researches on how acupuncture might modulate electrophysiological responses in the central nervous system (CNS and affect peripheral structures are reviewed.

  14. Delayed umbilical cord clamping after childbirth: potential benefits to baby's health

    Directory of Open Access Journals (Sweden)

    Uwins C

    2014-11-01

    Full Text Available Christina Uwins,1 David JR Hutchon2 1Department of Obstetrics and Gynaecology, Croydon University Hospital, Croydon, 2Department of Obstetrics, Darlington Memorial Hospital, Darlington, UKAbstract: Early cord clamping was initially introduced as part of the package of care known as “active management of the third stage”, which was implemented to reduce postpartum hemorrhage. It has now been shown to provide no benefit to the mother and to result in harm to the neonate. The clinical trial evidence relating to delayed cord clamping compared to immediate cord clamping is presented and the physiological rationale for delayed cord clamping is discussed in this paper. Most organizations (eg World Health Organization (WHO, Royal College of Obstetricians and Gynaecologists (RCOG, Resuscitation Council (UK,The International Federation of Gynecology and Obstetrics (FIGO, International Confederation of Midwives, International Liaison Committee on Resuscitation (ILCOR and the European Resuscitation Council now advise a delay of 1–3 minutes before clamping the cord in term and preterm infants, and clinicians need to be aware of this change. Healthy neonates benefit from a more physiological and gentle transition from placental to pulmonary respiration, and we explain why this benefit should be provided to all neonates until there is any evidence to the contrary. The harm of early cord clamping is not limited to anemia and iron deficiency, and evidence for a wide range of possible harms of early cord clamping is presented. The need for resuscitation is one of the most common concerns, and ways of overcoming these concerns are described.Keywords: transition, cord clamping, hypovolemia, intraventricular hemorrhage

  15. Biomechanical comparison of cervical fixation via transarticular facet screws without rods versus lateral mass screws with rods.

    Science.gov (United States)

    Yi, Seong; Rim, Dae-Cheol; Nam, Ki-Se; Keem, Sang-Hyun; Murovic, Judith A; Lim, Jesse; Park, Jon

    2015-04-01

    Transarticular facet screws restore biomechanical stability to the cervical spine when posterior cervical anatomy has been compromised. This study compares the more recent, less invasive, and briefer transarticular facet screw system without rods with the lateral mass screw system with rods. For this study, 6 human cervical spines were obtained from cadavers. Transarticular facet screws without rods were inserted bilaterally into the inferior articular facets at the C5-C6 and C5-C6-C7 levels. Lateral mass screws with rods were inserted bilaterally at the same levels using Magerl's technique. All specimens underwent range of motion (ROM) testing by a material testing machine for flexion, extension, lateral bending, and axial rotation. Both fixation methods, transarticular facet screws without rods and lateral mass screws with rods, reduced all ROM measurements and increased spinal stiffness. No statistically significant differences between the 2 stabilization methods were found in ROM measurements for 1-level insertions. However, in 2-level insertions, ROM for the nonrod transarticular facet screw group was significantly increased for flexion-extension and lateral bending. Transarticular facet screws without rods and lateral mass screws with rods had similar biomechanical stability in single-level insertions. For 2-level insertions, transarticular facet screws without rods are a valid option in cervical spine repair. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Patterns of rod proliferation in deep-sea fish retinae.

    Science.gov (United States)

    Fröhlich, E; Negishi, K; Wagner, H J

    1995-07-01

    In a sample of 37 species of deep-sea fish species from the sea floor of the Porcupine Seabight and the Gobal spur (North Atlantic) we investigated the overall structure of the retina with special respect for the organization of rods, their length and their arrangement in multiple banks. Using an immunocytochemical marker for cell proliferation (PCNA) we studied the mechanisms of rod proliferation, and, by means of serial section reconstruction followed their integration into the existing population of rods. Furthermore, in three different species we have observed growth related changes in retinal thickness, rod density and proliferation activity. We found evidence for two different principles for the organization of rods in these deep-sea fish retinae. In the first group of species represented by Nematonurus armatus and Coryphaenoides guentheri we found rods to be rather short (20-30 microns) and arranged in three and more banks. In these species rod proliferation occurred in a single band of cells immediately vitread of the external limiting membrane, thus showing a high degree of spatial and temporal order. In these species, young rods are inserted just sclerad of the external limiting membrane and the older outer segments pushed away from the incoming light towards the back of the eye. This may be linked to a progressive loss of function of the older rods and might represent an alternative mechanism to the disk shedding in other vertebrates. In the second population (e.g. Conocara macroptera, Alepocephalus agassizii) we observed considerably longer rod outer segments (60-80 microns) forming no more than two layers. These retinae had rod precursors arranged in disseminated clusters throughout the outer nuclear layer indicating the lack of clear spatio-temporal order in mitotic activity along with a more statistical pattern of integration of the newly formed outer segments. In our sample of species both populations were of about equal size suggesting that the two

  17. Investigation of axial power gradients near a control rod tip

    Energy Technology Data Exchange (ETDEWEB)

    Loberg, John, E-mail: John.Loberg@fysast.uu.se [Uppsala University, Department of Physics and Astronomy, Division of Applied Nuclear Physics, Box 525, SE-75120 Uppsala (Sweden); Osterlund, Michael, E-mail: Michael.Osterlund@fysast.uu.se [Uppsala University, Department of Physics and Astronomy, Division of Applied Nuclear Physics, Box 525, SE-75120 Uppsala (Sweden); Bejmer, Klaes-Hakan, E-mail: Klaes-Hakan.Bejmer@vattenfall.com [Vattenfall Nuclear Fuel AB, Jaemtlandsgatan 99, 162 60 Vaellingby, Stockholm (Sweden); Blomgren, Jan, E-mail: Jan.Blomgren@vattenfall.com [Vattenfall Nuclear Fuel AB, Jaemtlandsgatan 99, 162 60 Vaellingby, Stockholm (Sweden); Kierkegaard, Jesper, E-mail: Jesper.Kierkegaar@vattenfall.com [Vattenfall Nuclear Fuel AB, Jaemtlandsgatan 99, 162 60 Vaellingby, Stockholm (Sweden)

    2011-07-15

    Highlights: > Pin power gradients near BWR control rod tips have been investigated. > A control rod tip is modeled in MCNP and compared to simplified 2D/3D geometry. > Small nodes increases pin power gradients; standard nodes underestimates gradients. > The MCNP results are validated against axial gamma scan of a controlled fuel pin. - Abstract: Control rod withdrawal in BWRs induces large power steps in the adjacent fuel assemblies. This paper investigates how well a 2D/3D method, e.g., CASMO5/SIMULATE5 computes axial pin power gradients adjacent to an asymmetrical control-rod tip in a BWR. The ability to predict pin power gradients accurately is important for safety considerations whereas large powers steps induced by control rod withdrawal can cause Pellet Cladding Interaction. The computation of axial pin power gradients axially around a control rod tip is a challenging task for any nodal code. On top of that, asymmetrical control rod handles are present in some BWR designs. The lattice code CASMO requires diagonal symmetry of all control rod parts. This introduces an error in computed pin power gradients that has been evaluated by Monte Carlo calculations. The results show that CASMO5/SIMULATE5, despite the asymmetrical control rod handle, is able to predict the axial pin power gradient within 1%/cm for axial nodal sizes of 15-3.68 cm. However, a nodal size of 3.68 cm still causes underestimations of pin power gradients compared with 1 cm nodes. Furthermore, if conventional node sizes are used, {approx}15 cm, pin power gradients can be underestimated by over 50% compared with 1 cm nodes. The detailed axial pin power profiles from MCNP are corroborated by measured gamma scan data on fuel rods irradiated adjacent to control rods.

  18. Effect of non-ideal clamping shape on the resonance frequencies of silicon nanocantilevers

    Energy Technology Data Exchange (ETDEWEB)

    Guillon, Samuel; Saya, Daisuke; Mazenq, Laurent; Nicu, Liviu [CNRS, LAAS, 7 Avenue du Colonel Roche, F-31077 Toulouse Cedex 4 (France); Perisanu, Sorin; Vincent, Pascal [LPMCN, Universite Claude Bernard Lyon 1 et CNRS, 43 boulevard du 11 novembre 1918, 69622 Villeurbanne Cedex (France); Lazarus, Arnaud; Thomas, Olivier, E-mail: sguillon@laas.fr [Structural Mechanics and Coupled Systems Laboratory, Conservatoire National des Arts et Metiers, 2 rue Conte, 75003 Paris (France)

    2011-06-17

    In this paper, we investigate the effects of non-ideal clamping shapes on the dynamic behavior of silicon nanocantilevers. We fabricated silicon nanocantilevers using silicon on insulator (SOI) wafers by employing stepper ultraviolet (UV) lithography, which permits a resolution of under 100 nm. The nanocantilevers were driven by electrostatic force inside a scanning electron microscope (SEM). Both lateral and out-of-plane resonance frequencies were visually detected with the SEM. Next, we discuss overhanging of the cantilever support and curvature at the clamping point in the silicon nanocantilevers, which generally arises in the fabrication process. We found that the fundamental out-of-plane frequency of a realistically clamped cantilever is always lower than that for a perfectly clamped cantilever, and depends on the cantilever width and the geometry of the clamping point structure. Using simulation with the finite-elements method, we demonstrate that this discrepancy is attributed to the particular geometry of the clamping point (non-zero joining curvatures and a flexible overhanging) that is obtained in the fabrication process. The influence of the material orthotropy is also investigated and is shown to be negligible.

  19. A novel monolithic piezoelectric actuated flexure-mechanism based wire clamp for microelectronic device packaging

    Science.gov (United States)

    Liang, Cunman; Wang, Fujun; Tian, Yanling; Zhao, Xingyu; Zhang, Hongjie; Cui, Liangyu; Zhang, Dawei; Ferreira, Placid

    2015-04-01

    A novel monolithic piezoelectric actuated wire clamp is presented in this paper to achieve fast, accurate, and robust microelectronic device packaging. The wire clamp has compact, flexure-based mechanical structure and light weight. To obtain large and robust jaw displacements and ensure parallel jaw grasping, a two-stage amplification composed of a homothetic bridge type mechanism and a parallelogram leverage mechanism was designed. Pseudo-rigid-body model and Lagrange approaches were employed to conduct the kinematic, static, and dynamic modeling of the wire clamp and optimization design was carried out. The displacement amplification ratio, maximum allowable stress, and natural frequency were calculated. Finite element analysis (FEA) was conducted to evaluate the characteristics of the wire clamp and wire electro discharge machining technique was utilized to fabricate the monolithic structure. Experimental tests were carried out to investigate the performance and the experimental results match well with the theoretical calculation and FEA. The amplification ratio of the clamp is 20.96 and the working mode frequency is 895 Hz. Step response test shows that the wire clamp has fast response and high accuracy and the motion resolution is 0.2 μm. High speed precision grasping operations of gold and copper wires were realized using the wire clamper.

  20. A High Step-Down Interleaved Buck Converter with Active-Clamp Circuits for Wind Turbines

    Directory of Open Access Journals (Sweden)

    Chih-Lung Shen

    2012-12-01

    Full Text Available In this paper, a high step-down interleaved buck coupled-inductor converter (IBCC with active-clamp circuits for wind energy conversion has been studied. In high step-down voltage applications, an IBCC can extend duty ratio and reduce voltage stresses on active switches. In order to reduce switching losses of active switches to improve conversion efficiency, a IBCC with soft-switching techniques is usually required. Compared with passive-clamp circuits, the IBCC with active-clamp circuits have lower switching losses and minimum ringing voltage of the active switches. Thus, the proposed IBCC with active-clamp circuits for wind energy conversion can significantly increase conversion efficiency. Finally, a 240 W prototype of the proposed IBCC with active-clamp circuits was built and implemented. Experimental results have shown that efficiency can reach as high as 91%. The proposed IBCC with active-clamp circuits is presented in high step-down voltage applications to verify the performance and the feasibility for energy conversion of wind turbines.

  1. The effect of early and late umbilical cord clamping on neonatal hematocrit.

    Science.gov (United States)

    Jahazi, A; Kordi, M; Mirbehbahani, N B; Mazloom, S R

    2008-08-01

    To compare the effect of early and late cord clamping (LCC) on neonatal hematocrit at 2 and 18 h of life. In this double-blind randomized trial, 64 healthy full-term vaginally born neonates were randomly allocated to either early (30 s) or late (3 min) umbilical cord clamping. During the interval between delivery and cord clamping, the attendant held the neonate supine at the level of the introitus. Neonatal venous hematocrit was measured at 2 and 18 h of life. Neonatal hematocrit at 2 h of life (61+/-4.9 vs 61.6+/-4.5%) and 18 h of life (56.9+/-4.1 vs 56.2+/-3.9%) was not significantly different between the two groups. This was also true for neonatal polycythemia (20 vs 23.5%). In the LCC group, placental residual blood volume (PRBV) was 39.5% lower and estimated neonatal blood volume (ENBV) was 7.1% higher than that in the early cord clamping (ECC) group (Pcord clamping does not lead to a significant difference in the hematocrit level of the neonate or neonatal polycythemia, but is associated with a significant increase in ENBV and a significant decrease in PRBV. Further trials should examine the effect of delaying cord clamping for a longer period of time or changing the position that the neonate is held in to determine whether these variations result in more clinically significant results.

  2. Late umbilical cord clamping, neonatal hematocrit and Apgar scores: a randomized controlled trial.

    Science.gov (United States)

    Salari, Z; Rezapour, M; Khalili, N

    2014-01-01

    Based on current evidence, there is a little agreement on the best timing for after birth umbilical cord clamping. This study was designed to compare the impact of using two different times for cord clamping on hematocrit concentration and Apgar scores of the neonate. Fifty-six healthy full-term vaginally born neonates were allocated to early (10 seconds after delivery) and late (3 minutes after delivery) umbilical cord clamping groups in this randomized clinical trial. We recorded the length of the 3rd stage of labor and Apgar score at 5 minutes. Infant's hematocrit was measured at 2 and 18 hours of age. Neonatal hematocrit differed between the two groups. Late cord clamping group had greater hematocrit at 2 hours (45.5 ± 4 vs. 49.5 ± 4.4, P = 0.0003) and 18 hours (47.7 ± 5.5 vs. 52.9 ± 4.3, P = 0.0002). Apgar scores at 5 minutes (9.3 ± 0.6 vs. 9.4 ± 0.6, p = 0.5) and duration of delivery 3rd stage (10.2 ± 3.7 min vs. 8.9 ± 5 min, P = 0.2) did not differ between early and late cord clamping groups respectively. Late cord clamping leads to a significant increase in the hematocrit of the neonate but it does not have effects on Apgar score and duration of the 3rd stage of labor.

  3. Can selective arterial clamping with fluorescence imaging preserve kidney function during robotic partial nephrectomy?

    Science.gov (United States)

    McClintock, Tyler R; Bjurlin, Marc A; Wysock, James S; Borofsky, Michael S; Marien, Tracy P; Okoro, Chinonyerem; Stifelman, Michael D

    2014-08-01

    To compare renal functional outcomes in robotic partial nephrectomy (RPN) with selective arterial clamping guided by near-infrared fluorescence (NIRF) imaging to a matched cohort of patients who underwent RPN without selective arterial clamping and NIRF imaging. From April 2011 to December 2012, NIRF imaging-enhanced RPN with selective clamping was used in 42 cases. Functional outcomes of successful cases were compared with a cohort of patients, matched by tumor size, preoperative estimated glomerular filtration rate (eGFR), functional kidney status, age, sex, body mass index, and American Society of Anesthesiologists score, who underwent RPN without selective clamping and NIRF imaging. In matched-pair analysis, selective clamping with NIRF was associated with superior kidney function at discharge, as demonstrated by postoperative eGFR (78.2 vs 68.5 mL/min/1.73 m(2); P = .04), absolute reduction of eGFR (-2.5 vs -14.0 mL/min/1.73 m(2); P functional outcomes when compared with RPN without selective arterial clamping and NIRF imaging. With this effect attenuated at later follow-up, randomized prospective studies and long-term assessment of kidney-specific functional outcomes are needed to further assess the benefits of this technology. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. The effect of impurity on transition frequency of bound polaron in quantum rods

    Indian Academy of Sciences (India)

    Wei Xiao; Jing-Lin Xiao

    2012-12-01

    The Hamiltonian of a quantum rod with an ellipsoidal boundary is given after a coordinate transformation that changes the ellipsoidal boundary into a spherical one. The properties of the quantum rods constituting the bridge between two-dimensional quantum wells, zero-dimensional quantum dots and one-dimensional quantum wires are explored theoretically using linear combination operator method. The first internal excited state energy, the excitation energy and the transition frequency between the first internal excited and the ground states of the strong-coupled impurity-bound polaron in the rod with Coulomb-bound potential, the transverse effective confinement length, the ellipsoid aspect ratio and the electron–phonon coupling strength are studied. It is found that the first internal excited state energy, the excitation energy and the transition frequency are increasing functions of the Coulomb-bound potential and the electron–phonon coupling strength, whereas they are decreasing functions of the ellipsoid aspect ratio and the transverse effective confinement length. These results can be attributed to the interesting quantum size confining effects.

  5. The Formation of the Surface during AN Abrasive Finishing at Constant and Variable Clamping Forces: Finishing at Constant and Variable Clamping Forces

    Science.gov (United States)

    Muratov, Karim Ravilevich; Muratov, Ravil Arifovich; Ablyaz, Timur Rizovich; Gashev, Evgeniy Anatolyevich

    2017-06-01

    In this work the flat abrasive finishing process is reported. The mechanical and chemical phenomena taking place during the finishing process are described. The most common forming process schemes observed during abrasive treatment are reviewed. The schemes of pulsed, geometrical and energetic models are discussed. On the basis of the energetic hypothesis and Preston hypothesis, the rational law of clamping force variation during the finishing is established. This law allowed for the stabilization of the contact pressure and an increase of the treatment efficiency. An exponential dependence of a boundary contact area variation during the finishing of planes with different initial profiles of the macro-topography is developed. An experimental confirmation of the Preston hypothesis during the abrasive finishing is carried out with the plane-finishing machine “Rastr 220”. The comparison experiments are carried out at constant and variable clamping forces of the treated surface towards the tool. It is found that by varying the forces according to the exponential law (i.e. similar to the changing of the boundary contact area during the abrasive finishing) the process efficiency is increasing by a factor of 2.5-3. It is shown that the changes of the root mean square deviation σ of the roughness Ra of a treated surface in the beginning of the process (at time t=1 min) during the finishing at a constant clamping force is two times higher compared to the treatment at a variable clamping force in the same time period.

  6. Cleanup Verification Package for the 118-C-1, 105-C Solid Waste Burial Ground

    Energy Technology Data Exchange (ETDEWEB)

    M. J. Appel and J. M. Capron

    2007-07-25

    This cleanup verification package documents completion of remedial action for the 118-C-1, 105-C Solid Waste Burial Ground. This waste site was the primary burial ground for general wastes from the operation of the 105-C Reactor and received process tubes, aluminum fuel spacers, control rods, reactor hardware, spent nuclear fuel and soft wastes.

  7. M. tuberculosis sliding β-clamp does not interact directly with the NAD+-dependent DNA ligase.

    Directory of Open Access Journals (Sweden)

    Vandna Kukshal

    Full Text Available The sliding β-clamp, an important component of the DNA replication and repair machinery, is drawing increasing attention as a therapeutic target. We report the crystal structure of the M. tuberculosis β-clamp (Mtbβ-clamp to 3.0 Å resolution. The protein crystallized in the space group C222(1 with cell-dimensions a = 72.7, b = 234.9 & c = 125.1 Å respectively. Mtbβ-clamp is a dimer, and exhibits head-to-tail association similar to other bacterial clamps. Each monomer folds into three domains with similar structures respectively and associates with its dimeric partner through 6 salt-bridges and about 21 polar interactions. Affinity experiments involving a blunt DNA duplex, primed-DNA and nicked DNA respectively show that Mtbβ-clamp binds specifically to primed DNA about 1.8 times stronger compared to the other two substrates and with an apparent K(d of 300 nM. In bacteria like E. coli, the β-clamp is known to interact with subunits of the clamp loader, NAD(+-dependent DNA ligase (LigA and other partners. We tested the interactions of the Mtbβ-clamp with MtbLigA and the γ-clamp loader subunit through radioactive gel shift assays, size exclusion chromatography, yeast-two hybrid experiments and also functionally. Intriguingly while Mtbβ-clamp interacts in vitro with the γ-clamp loader, it does not interact with MtbLigA unlike in bacteria like E. coli where it does. Modeling studies involving earlier peptide complexes reveal that the peptide-binding site is largely conserved despite lower sequence identity between bacterial clamps. Overall the results suggest that other as-yet-unidentified factors may mediate interactions between the clamp, LigA and DNA in mycobacteria.

  8. Switch isotropic/anisotropic wettability via dual-scale rods

    Directory of Open Access Journals (Sweden)

    Yang He

    2014-10-01

    Full Text Available It is the first time to demonstrate the comparison of isotropic/anisotropic wettability between dual-scale micro-nano-rods and single-scale micro-rods. Inspired by the natural structures of rice leaf, a series of micro-nano-rods and micro-rods with different geometric parameters were fabricated using micro-fabrication technology. Experimental measured apparent contact angles and advancing and receding contact angles from orthogonal orientations were characterized. The difference of contact angles from orthogonal orientation on dual-scale rods was much smaller than those on single-scale rods in both static and dynamic situation. It indicated that the dual-scale micro-nano-rods showed isotropic wettability, while single-scale micro-rods showed anisotropic wettability. The switch of isotropic/anisotropic wettability could be illustrated by different wetting state and contact line moving. It offers a facial way to switch isotropic/anisotropic wettability of the surface via dual-scale or single-scale structure.

  9. Switch isotropic/anisotropic wettability via dual-scale rods

    Science.gov (United States)

    He, Yang; Jiang, Chengyu; Wang, Shengkun; Ma, Zhibo; Yuan, Weizheng

    2014-10-01

    It is the first time to demonstrate the comparison of isotropic/anisotropic wettability between dual-scale micro-nano-rods and single-scale micro-rods. Inspired by the natural structures of rice leaf, a series of micro-nano-rods and micro-rods with different geometric parameters were fabricated using micro-fabrication technology. Experimental measured apparent contact angles and advancing and receding contact angles from orthogonal orientations were characterized. The difference of contact angles from orthogonal orientation on dual-scale rods was much smaller than those on single-scale rods in both static and dynamic situation. It indicated that the dual-scale micro-nano-rods showed isotropic wettability, while single-scale micro-rods showed anisotropic wettability. The switch of isotropic/anisotropic wettability could be illustrated by different wetting state and contact line moving. It offers a facial way to switch isotropic/anisotropic wettability of the surface via dual-scale or single-scale structure.

  10. Probabilistic thermo-chemical analysis of a pultruded composite rod

    NARCIS (Netherlands)

    Baran, Ismet; Tutum, Cem C.; Hattel, Jesper H.

    2012-01-01

    In the present study the deterministic thermo-chemical pultrusion simulation of a composite rod taken from the literature [7] is used as a validation case. The predicted centerline temperature and cure degree profiles of the rod match well with those in the literature [7]. Following the validation c

  11. Probabilistic thermo-chemical analysis of a pultruded composite rod

    DEFF Research Database (Denmark)

    Baran, Ismet; Tutum, Cem Celal; Hattel, Jesper Henri

    2012-01-01

    In the present study the deterministic thermo-chemical pultrusion simulation of a composite rod taken from the literature [7] is used as a validation case. The predicted centerline temperature and cure degree profiles of the rod match well with those in the literature [7]. Following the validation...

  12. Optimized Control Rods of the BR2 Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Kalcheva, Silva; Koonen, E.

    2007-09-15

    At the present time the BR-2 reactor uses control elements with cadmium as neutron absorbing part. The lower section of the control element is a beryllium assembly cooled by light water. Due to the burn up of the lower end of the cadmium section during the reactor operation, the presently used rods for reactivity control of the BR-2 reactor have to be replaced by new ones. Considered are various types Control Rods with full active part of the following materials: cadmium (Cd), hafnium (Hf), europium oxide (Eu2O3) and gadolinium (Gd2O3). Options to decrease the burn up of the control rod material in the hot spot, such as use of stainless steel in the lower active part of the Control Rod are discussed. Comparison with the characteristics of the presently used Control Rods types is performed. The changing of the characteristics of different types Control Rods and the perturbation effects on the reactor neutronics during the BR-2 fuel cycle are investigated. The burn up of the Control Rod absorbing material, total and differential control rods worth, macroscopic and effective microscopic absorption cross sections, fuel and reactivity evolution are evaluated during approximately 30 operating cycles.

  13. Directed Assembly of colloidal rods, spheres and their mixtures

    NARCIS (Netherlands)

    Bakker, H.E.

    2017-01-01

    The directed assembly of colloidal rods, spheres and their mixtures in external fields such as gravity, electric fields and shear flow was investigated. Using confocal microscopy we determined the experimental phase diagram of a binary mixture of colloidal silica rods and spheres that form a binary

  14. Isotropic-to-nematic nucleation in suspensions of colloidal rods

    NARCIS (Netherlands)

    Cuetos, A.; van Roij, R.H.H.G.; Dijkstra, M.

    2008-01-01

    Using computer simulations, we study the isotropic-to-nematic nucleation in a fluid of colloidal hard rods as well as in a mixture of colloidal rods and non-adsorbing polymer. In order to follow the transformation of the system from the isotropic to the nematic phase, we use a new cluster criterion

  15. Numerical investigation of flow past a row of rectangular rods

    Directory of Open Access Journals (Sweden)

    S.Ul. Islam

    2016-09-01

    Full Text Available A numerical study of uniform flow past a row of rectangular rods with aspect ratio defined as R = width/height = 0.5 is performed using the Lattice Boltzmann method. For this study the Reynolds number (Re is fixed at 150, while spacings between the rods (g are taken in the range from 1 to 6. Depending on g, the flow is classified into four patterns: flip-flopping, nearly unsteady-inphase, modulated inphase-antiphase non-synchronized and synchronized. Sudden jumps in physical parameters were observed, attaining either maximum or minimum values, with the change in flow patterns. The mean drag coefficient (Cdmean of middle rod is higher than the second and fourth rod for flip-flopping pattern while in case of nearly unsteady-inphase the middle rod attains minimum drag coefficient. It is also found that the Strouhal number (St of first, second and fifth rod decreases as g increases while that of other two have mixed trend. The results further show that there exist secondary interaction frequencies together with primary vortex shedding frequency due to jet in the gap between rods for 1 ⩽ g ⩽ 3. For the average values of Cdmean and St, an empirical relation is also given as a function of gap spacing. This relation shows that the average values of Cdmean and St approach to those of single rectangular rod with increment in g.

  16. Approximation in LQG control of a thermoelastic rod

    Science.gov (United States)

    Gibson, J. S.; Rosen, I. G.; Tao, G.

    1989-01-01

    Control and estimator gains are computed for linear-quadratic-Gaussian (LQG) optimal control of the axial vibrations of a thermoelastic rod. The computations are based on a modal approximation of the partial differential equations representing the rod, and convergence of the approximations to control and estimator gains is the main issue.

  17. Control rod drive for high temperature gas cooled reactor

    Institute of Scientific and Technical Information of China (English)

    DengJun-Xian; XuJi-Ming; 等

    1998-01-01

    This control rod drive is developed for HTR-10 high temperature gas cooled test reactor.The stepmotor is prefered to improve positioning of the control rod and the scram behavior.The preliminary test in 1600170 ambient temperature shows that the selected stepmotor and transmission system can meet the main operation function requirements of HTR-10.

  18. Chitosan rod reinforced by self-crosslinking through thermal treatment

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Chitosan (CS) rods were reinforced at high temperatures to form network structure by self-crosslinking of amino groups.Properties of treated CS rods were studied by FTIR spectroscopy,intrinsic viscosity measurement,mechanical properties testing and water absorption measurement.The FTIR spectra indicated that the CS configuration was transformed from β-CS for untreated CS rods to α-CS for thermally treated CS rods.Meanwhile,the crosslinking also occurred between amino groups of CS.Due to the increase in the crosslinking degree,the intrinsic viscosity increased with the rising of temperature.It was found that the network structure enhanced the bending strength of CS rods,which reached 154.8 MPa when CS rods were treated at 140℃ for 2 h.Thermal treatment also reduced the water absorption of CS rods.Due to the improved mechanical properties,thermally treated CS rods could be used as a novel device for internal fixation of bone fracture.

  19. 49 CFR 236.794 - Rod, up-and-down.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Rod, up-and-down. 236.794 Section 236.794 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION..., up-and-down. A rod used for connecting the semaphore arm to the operating mechanism of a signal....

  20. Optimization of fuel rod enrichment distribution for BWR fuel assembly

    Energy Technology Data Exchange (ETDEWEB)

    Hirano, Yasushi; Hida, Kazuki; Sakurada, Koichi; Yamamoto, Munenari [Toshiba Corp., Kawasaki, Kanagawa (Japan). Nuclear Engineering Lab.

    1996-09-01

    A practical method was developed for determining the optimum fuel enrichment distribution within a boiling water reactor fuel assembly. The method deals with two different optimization problems, i.e. the combinatorial optimization problem of grouping fuel rods into a given number of rod groups with the same enrichment, and the problem of determining an optimal enrichment for each fuel rod under the resultant rod-grouping pattern. In solving these problems, the primary goal is to minimize a predefined objective function over a given exposure period. The objective function used here is defined by the linear combination C{sub 1}X + C{sub 2}X{sub G}, where X and X{sub G} stand, respectively, for control variables giving constraint to the local power peaking factor and the gadolinium rod power. C{sub 1} and C{sub 2} are user-definable weighting factors to accommodate design preferences. The algorithm for solving this combinatorial optimization problem starts by finding the optimal enrichment vector without any rod-grouping, and promising candidates of rod-grouping patterns are found by exhaustive enumeration based on the resulting fuel enrichment ordering. This latter problem is solved using the method of approximation programming. A practical application is shown for a contemporary 8 x 8 Pu mixed-oxide fuel assembly with 10 gadolinium-poisoned rods. (author)

  1. Biomolecular rods and tubes in nanotechnology

    Science.gov (United States)

    Bittner, Alexander M.

    2005-02-01

    Biomolecules are vitally important elements in nanoscale science and also in future nanotechnology. Their shape and their chemical and physical functionality can give them a big advantage over inorganic and organic substances. While this becomes most obvious in proteins and peptides, with their complicated, but easily controlled chemistry, other biomolecular substances such as DNA, lipids and carbohydrates can also be important. In this review, the emphasis is on one-dimensional molecules and on molecules that self-assemble into linear structures, and on their potential applications. An important aspect is that biomolecules can act as templates, i.e. their shape and chemical properties can be employed to arrange inorganic substances such as metals or metal compounds on the nanometre scale. In particular, rod- and tube-like nanostructures can show physical properties that are different from those of the bulk material, and thus these structures are likely to be a basis for new technology.

  2. Electric Fuel Rod Simulator Fabrication at ORNL

    Science.gov (United States)

    Ott, Larry J.; McCulloch, Reg

    2004-02-01

    Commercial vendors could not supply the high-quality, highly instrumented electric fuel rod simulators (FRS) required for large thermal-hydraulic safety-oriented experiments at the Oak Ridge National Laboratory (ORNL) in the 1970s and early 1980s. Staff at ORNL designed, developed, and manufactured the simulators utilized in these safety experiments. Important FRS design requirements include (1) materials of construction, (2) test power requirements and availability, (3) experimental test objectives, (4) supporting thermal analyses, and (5) extensive quality control throughout all phases of FRS fabrication. This paper will present an overview of these requirements (design, analytics, and quality control) as practiced at ORNL to produce a durable high-quality FRS.

  3. Axial thermal rotation of slender rods.

    Science.gov (United States)

    Li, Dichuan; Fakhri, Nikta; Pasquali, Matteo; Biswal, Sibani Lisa

    2011-05-06

    Axial rotational diffusion of rodlike polymers is important in processes such as microtubule filament sliding and flagella beating. By imaging the motion of small kinks along the backbone of chains of DNA-linked colloids, we produce a direct and systematic measurement of axial rotational diffusivity of rods both in bulk solution and near a wall. The measured diffusivities decrease linearly with the chain length, irrespective of the distance from a wall, in agreement with slender-body hydrodynamics theory. Moreover, the presence of small kinks does not affect the chain's axial diffusivity. Our system and measurements provide insights into fundamental axial diffusion processes of slender objects, which encompass a wide range of entities including biological filaments and linear polymer chains.

  4. Study of the anti-sand sucker rod pump

    Science.gov (United States)

    Wei, Hangxin; Lv, Bingxin; Xi, Wenkui; Yi, Peng

    2017-06-01

    In order to solve the problem of sand stuck in the sucker rod pump, an anti-sand sucker rod pump is designed. The anti-sand sucker rod pump includes the conventional sucker rod pump and the swirl flow device. The sand particles can be separated from the oil in the swirl flow device, so the plunger of the sucker rod pump cannot be stuck. The motion equation of the sand particles in oil is deduced. The virtual model of the swirl flow device is built in GAMBIT software. And simulation of solid-liquid two phase flow is simulated in software FLUENT. The simulation results show that the swirl flow device can realize the sand particles separation from the oil completely. So the pump can have the effect of anti-sands.

  5. Investigating the optical XNOR gate using plasmonic nano-rods

    Science.gov (United States)

    Akhlaghi, Majid; Kaboli, Milad

    2016-04-01

    In this paper, a coherent perfect absorption (CPA)-type XNOR gate based on plasmonic nano particle is proposed. It consists of two plasmonic nano rod arrays on top of two parallel arms with quartz substrate. The operation principle is based on the absorbable formation of a conductive path in the dielectric layer of a plasmonic nano-particles waveguide. Since the CPA efficiency depends strongly on the number of plasmonic nano-rod and the nano rod location, an efficient binary optimization method based the Particle Swarm Optimization (PSO) algorithm is used to design an optimized array of the plasmonic nano-rod in order to achieve the maximum absorption coefficient in the 'off' state and the minimum absorption coefficient in the 'on' state. In Binary PSO (BPSO), a group of birds consists a matrix with binary entries, control the presence ('1‧) or the absence ('0‧) of nano rod in the array.

  6. Semiconductor Quantum Rods as Single Molecule FluorescentBiological Labels

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Aihua; Gu, Weiwei; Boussert, Benjamine; Koski, Kristie; Gerion, Daniele; Manna, Liberato; Le Gros, Mark; Larabell, Carolyn; Alivisatos, A. Paul

    2006-05-29

    In recent years, semiconductor quantum dots have beenapplied with great advantage in a wide range of biological imagingapplications. The continuing developments in the synthesis of nanoscalematerials and specifically in the area of colloidal semiconductornanocrystals have created an opportunity to generate a next generation ofbiological labels with complementary or in some cases enhanced propertiescompared to colloidal quantum dots. In this paper, we report thedevelopment of rod shaped semiconductor nanocrystals (quantum rods) asnew fluorescent biological labels. We have engineered biocompatiblequantum rods by surface silanization and have applied them fornon-specific cell tracking as well as specific cellular targeting. Theproperties of quantum rods as demonstrated here are enhanced sensitivityand greater resistance for degradation as compared to quantum dots.Quantum rods have many potential applications as biological labels insituations where their properties offer advantages over quantumdots.

  7. Fatigue Life Improving of Drill Rod by Inclusion Control

    Science.gov (United States)

    Wang, Linzhu; Yang, Shufeng; Li, Jingshe; Liu, Wei; Zhou, Yinghao

    2016-08-01

    Large and hard inclusions often deteriorate the service performance and reduce the fatigue lifetime of drill rods. In this paper, the main reasons of the rupture of drill rods were analyzed by the examination of their fracture and it is found that the large inclusions were the main reason of breakage of rod drill. The inclusions were high of Ca content or Al2O3 rich. Smaller and better deformability inclusions were obtained by the optimization of refining slag, calcium treatment process and the flow control devices of tundish. Results of industrial experiment after optimization show that total oxygen content of drill rods decreased by more than 50%, macro-inclusions weight fraction decreased from about 4 mg/10 kg to about 0.3 mg/10 kg and the micro-inclusions average size decreased from 6 to 3.6 μm. The average using times of drill rods after optimization were increased by about 60%.

  8. Control wetting state transition by micro-rod geometry

    Science.gov (United States)

    He, Yang; Jiang, Chengyu; Wang, Shengkun; Yin, Hengxu; Yuan, Weizheng

    2013-11-01

    Understanding the effect of micro-structure geometry on wetting state transition is important to design and control surface wettability. Micro-rod model was proposed and the relationship between micro-rod geometry and wetting state was investigated in the paper taking into account only the surface roughness and neglecting the chemistry interaction. Micro-rods with different geometric parameters were fabricated using micro-fabrication technology. Their contact angles were measured and compared with theoretical ones. The experimental results indicated that increasing the height and decreasing the space of micro-rod may result in Cassie wetting state, while decreasing the height and increasing the space may result in Wenzel wetting state. A suspended wetting state model due to scallops was proposed. The wetting state transition was interpreted by intruding height, de-pinning and sag mechanism. It may offer a facile way to control the surface wetting state transition by changing the geometry of micro-rod.

  9. Controllable single photon stimulation of retinal rod cells

    CERN Document Server

    Phan, Nam Mai; Bessarab, Dmitri A; Krivitsky, Leonid A

    2013-01-01

    Retinal rod cells are commonly assumed to be sensitive to single photons [1, 2, 3]. Light sources used in prior experiments exhibit unavoidable fluctuations in the number of emitted photons [4]. This leaves doubt about the exact number of photons used to stimulate the rod cell. In this letter, we interface rod cells of Xenopus laevis with a light source based on Spontaneous Parametric Down Conversion (SPDC) [5], which provides one photon at a time. Precise control of generation of single photons and directional delivery enables us to provide unambiguous proof of single photon sensitivity of rod cells without relying on the statistical assumptions. Quantum correlations between single photons in the SPDC enable us to determine quantum efficiency of the rod cell without pre-calibrated reference detectors [6, 7, 8]. These results provide the path for exploiting resources offered by quantum optics in generation and manipulation of light in visual studies. From a more general perspective, this method offers the ult...

  10. Entropical Colloidal Interaction in Rod-like Molecules Solution

    Science.gov (United States)

    Hohlfeld, Evan B.; Lin, Keng-Hui; Zeri, Ana Carolina; Crocker, John C.; Yodh, Arjun G.

    2001-03-01

    We report direct measurements of the functional form of the depletion interaction between two colloidal spheres in a rod-like molecule suspension the line-scanned optical tweezer. The rod like moleculses are bacteriaphage fd with length (L) 880 nm and diameter(D) 6.5 nm and TMV with L 300 nm and D 200 nm. We probed different ratios of sphere radius R and rod length L and compared with theoretical models of Yaman^. The experimental data agrees with the model with slight discrepancy due to the flexibility of rod molecules. At high salt concentration, we also observed the steric repulsion due rod molecule stuck on the spheres. We gratefully acknowledge support from the NSF (DMR-9623441) and MRSEC (DMR-9632598). K. Yaman, C. Jeppesen and C.M. Marques, Europhys. Lett., 42, 221 (1998).

  11. Jourdain Principle of a Super-Thin Elastic Rod Dynamics

    Institute of Scientific and Technical Information of China (English)

    XUE Yun; SHANG Hui-Lin

    2009-01-01

    A super thin elastic rod is modeled with a background of DNA super coiling structure, and its dynamics is discussed based on the Jourdain variation. The cross section of the rod is taken as the object of this study and two velocity spaces about arc coordinate and the time are obtained respectively. Virtual displacements of the section on the two velocity spaces are defined and can be expressed in terms of Jourdaln variation. Jourdain principles of a super thin elastic rod dynamics on arc coordinate and the time velocity space are established,respectively, which show that there are two ways to realize the constraint conditions. If the constitutive relation of the rod is linear, the Jourdaln principle takes the Euler-Lagrange form with generalized coordinates. The Kirchhoff equation, Lagrange equation and Appell equation can be derived from the present Jourdaln principle.While the rod subjected to a surface constraint, Lagrange equation with undetermined multipliers may be derived.

  12. Systematic parametric design/calculation of the piston rod unit

    Science.gov (United States)

    Kacani, V.

    2015-08-01

    In this article a modern and economic method for the strength calculation of the piston rod unit and its components under different operating conditions will be presented. Herefore the commercial FEA - Software will be linked with the company-owned calculation tools. The parametric user input will be followed by an automatic Pre- and Postprocessing. Afterwards the strength calculation is processed on all critical points of the piston rod connection, assisted by an extra module, based on general standards and special codes for reciprocating compressors. In this process most arrangements of the piston rod unit as well as the special geometries of the single-components (piston, piston rod and piston nut) can be considered easily. In this article the modeling of the notches, especially on the piston rod, piston as well as the piston nut will be covered in detail.

  13. Optimization of fuel rod enrichment distribution to minimize rod power peaking throughout life within BWR fuel assembly

    Energy Technology Data Exchange (ETDEWEB)

    Hirano, Yasushi; Hida, Kazuki; Sakurada, Koichi; Yamamoto, Munenari [Toshiba Corp., Kawasaki, Kanagawa (Japan). Nuclear Engineering Lab.

    1997-01-01

    A practical method was developed for determining the optimum fuel enrichment distribution within a boiling water reactor fuel assembly. The method deals with two different optimization problems, i.e. a combinatorial optimization problem grouping fuel rods into a given number of rod groups with the same enrichment, and a problem determining an optimal enrichment for each fuel rod under the resultant rod-grouping pattern. In solving these problems, the primary goal is to minimize a predefined objective function over a given exposure period. The objective function used here is defined by a linear combination: C{sub 1}X+C{sub 2}X{sub G}, where X and X{sub G} stand for a control variable to give the constraint respectively for a local power peaking factor and a gadolinium rod power, and C{sub 1} and C{sub 2} are user-definable weighting factor to accommodate the design preference. The algorithm of solving the combinatorial optimization problem starts with finding the optimal enrichment vector without any rod-grouping, and promising candidates of rod-grouping patterns are found by exhaustive enumeration based on the resulting fuel enrichment ordering, and then the latter problem is solved by using the method of approximation programming. The practical application of the present method is shown for a contemporary 8x8 Pu mixed-oxide fuel assembly with 10 gadolinium-poisoned rods. (author)

  14. A central swivel point in the RFC clamp loader controls PCNA opening and loading on DNA.

    Science.gov (United States)

    Sakato, Miho; O'Donnell, Mike; Hingorani, Manju M

    2012-02-17

    Replication factor C (RFC) is a five-subunit complex that loads proliferating cell nuclear antigen (PCNA) clamps onto primer-template DNA (ptDNA) during replication. RFC subunits belong to the AAA(+) superfamily, and their ATPase activity drives interactions between the clamp loader, the clamp, and the ptDNA, leading to topologically linked PCNA·ptDNA. We report the kinetics of transient events in Saccharomyces cerevisiae RFC-catalyzed PCNA loading, including ATP-induced RFC activation, PCNA opening, ptDNA binding, ATP hydrolysis, PCNA closing, and PCNA·ptDNA release. This detailed perspective enables assessment of individual RFC-A, RFC-B, RFC-C, RFC-D, and RFC-E subunit functions in the reaction mechanism. Functions have been ascribed to RFC subunits previously based on a steady-state analysis of 'arginine-finger' ATPase mutants; however, pre-steady-state analysis provides a different view. The central subunit RFC-C serves as a critical swivel point in the clamp loader. ATP binding to this subunit initiates RFC activation, and the clamp loader adopts a spiral conformation that stabilizes PCNA in a corresponding open spiral. The importance of RFC subunit response to ATP binding decreases as RFC-C>RFC-D>RFC-B, with RFC-A being unnecessary. RFC-C-dependent activation of RFC also enables ptDNA binding, leading to the formation of the RFC·ATP·PCNA(open)·ptDNA complex. Subsequent ATP hydrolysis leads to complex dissociation, with RFC-D activity contributing the most to rapid ptDNA release. The pivotal role of the RFC-B/C/D subunit ATPase core in clamp loading is consistent with the similar central location of all three ATPase active subunits of the Escherichia coli clamp loader.

  15. Timing of umbilical cord-clamping and infant anaemia: the role of maternal anaemia.

    Science.gov (United States)

    Blouin, Brittany; Penny, Mary E; Maheu-Giroux, Mathieu; Casapía, Martín; Aguilar, Eder; Silva, Hermánn; Creed-Kanashiro, Hilary M; Joseph, Serene A; Gagnon, Anita; Rahme, Elham; Gyorkos, Theresa W

    2013-05-01

    Evidence from randomized controlled trials has shown that delayed cord-clamping is beneficial to infant iron status. The role of maternal anaemia in this relationship, however, has not been established. To determine the effect of maternal anaemia at delivery on the association between timing of umbilical cord-clamping and infant anaemia at 4 and 8 months of age. A cohort of pregnant women admitted to the labour room of Hospital Iquitos (Iquitos, Peru) and their newborns were recruited into the study during two time periods (18 May to 3 June and 6-20 July 2009). Between the two recruitment periods, the hospital's policy changed from early to delayed umbilical cord-clamping. Maternal haemoglobin levels were measured before delivery, and the time between delivery and cord-clamping was recorded at delivery for the entire cohort. Mother-infant pairs were followed-up at 4 (n = 207) and 8 months (n = 184) post partum. Infant haemoglobin levels were measured at follow-up visits. Data were analysed using logistic regression models. The prevalence of maternal anaemia (Hb cord-clamping and infant anaemia was modified by the mother's anaemia status. Significant benefits of delayed cord-clamping in preventing anaemia were found in infants born to anaemic mothers at both 4 months (aOR = 0.59, 95% CI 0.36-0.99) and 8 months (aOR = 0.38, 95% CI 0.19-0.76) of age. The study contributes additional evidence in support of delayed cord-clamping. This intervention is likely to have most public health impact in areas with a high prevalence of anaemia during pregnancy.

  16. Timing of umbilical cord clamping after birth for optimizing placental transfusion.

    Science.gov (United States)

    Raju, Tonse N K

    2013-04-01

    A brief delay in clamping the umbilical cord after birth offers health benefits to the newborn, with no adverse effects to the mother or her infant. Yet, in most obstetric practice, the cord is clamped soon after birth. A summary of the current evidence on delayed cord clamping and some reasons for the disconnect between the evidence and practice are discussed here, along with the recommendations from professional organizations and societies about this practice. In term infants, umbilical cord clamping between 30 and 180 s after birth results in higher concentrations of hemoglobin and hematocrit during the neonatal period, and increased serum ferritin levels and a lower incidence of iron-deficiency anemia at 4-6 months of age. These are important benefits for children in low and middle income countries where iron-deficiency anemia is highly prevalent. In preterm infants, delayed cord clamping for at least 30 s increases the concentrations of hemoglobin and hematocrit, improves mean systemic blood pressure, urine output, and cardiac function, and decreases the need for vasopressors and blood transfusions during the neonatal period. It also decreases the prevalence of necrotizing enterocolitis, sepsis, and intraventricular hemorrhage (all grades). Milking of the unclamped umbilical cord toward the infant soon after birth also has similar beneficial effects. In some studies, more infants in the delayed cord clamping groups required phototherapy for jaundice. Many professional organizations, societies, and experts recommend at least a 30-s delay before clamping the umbilical cord, especially after preterm births. The value of this practice for term births in resource-rich settings has not been evaluated.

  17. Umbilical cord blood acid-base and gas analysis after early versus delayed cord clamping in neonates at term.

    Science.gov (United States)

    De Paco, Catalina; Florido, Jesús; Garrido, Mari Carmen; Prados, Sonia; Navarrete, Luis

    2011-05-01

    To compare umbilical cord acid-base status and blood gas analysis between umbilical cords clamped within 10 s and at 2 min of delivery. A total of 158 healthy full-term mothers were randomly assigned to an early clamping (clamping (2 min post-delivery, n = 79) group. After application of inclusion criteria, umbilical vein blood acid-base status and gases were analyzed in 65 early clamped and 51 delayed clamped cords. Fewer cases could be examined in the umbilical artery: 55 cords in the early clamping group and 44 in the delayed one. Acid-base and gas analysis results did not significantly differ between the groups in the umbilical vein or umbilical artery, with the exception of a higher (p umbilical artery pO(2) value in the delayed versus early clamping group. No significant differences in umbilical vein or artery pCO(2) or HCO(3) (-) values were observed between the early and delayed clamp groups. A delay of 2 min before umbilical cord clamping does not significantly change acid-base and gas analysis results, with the exception of a higher mean umbilical artery pO(2) value in the delayed clamping group.

  18. Clampe de Ganz no tratamento de urgência em lesões do anel pélvico Ganz clamps to treat emergencies in pelvic ring lesions

    Directory of Open Access Journals (Sweden)

    Gilberto José Cação Pereira

    2008-07-01

    Full Text Available OBJETIVO: Avaliar a eficiência do clampe de Ganz na estabilização e redução dos deslocamentos da pelve, quando utilizado no tratamento de urgência, além de aquilatar eventuais dificuldades e facilidades do método. MÉTODOS: O clampe de Ganz foi utilizado no tratamento de urgência em 31 pacientes com graves lesões do anel pélvico (Tile C associadas a importante instabilidade hemodinâmica. RESULTADO: Entre os pacientes, 27 (87,1% apresentaram evolução favorável, com estabilização, redução dos deslocamentos e compressão da região posterior do anel, além de estabilização hemodinâmica, e quatro (12,9% evoluíram para óbito. CONCLUSÃO: O clampe de Ganz mostrou-se eficiente ferramenta no tratamento de urgência das lesões do anel pélvico, por ser de concepção simples, de rápida colocação, não impedir ou dificultar procedimentos no abdome e, principalmente, por permitir a estabilização da pelve, redução dos deslocamentos e compressão na região posterior do anel, local onde ocorrem os maiores sangramentos, reduzindo-os ou eliminando-os.OBJECTIVE: To evaluate the effectiveness of Ganz clamp to stabilize and reduce pelvic dislocations in emergency situations, and to assess possible difficult and easy aspects of the method. METHOD: Ganz clamp was used in the emergency treatment of 31 patients with severe lesions of the pelvic ring (Tile C associated to major hemodynamic instability. RESULTS: Among the patients, 27 (87.1% presented a favorable evolution, with stabilization, reduction of dislocations, and compression of the posterior portion of the ring, and also hemodynamic stabilization, and 4 (12.9% died. CONCLUSION: The Ganz clamp was found to be an effective tool in the emergency treatment of pelvic ring lesions because it has an uncomplicated conception, allowing for a fast placement, because it does not prevent nor make it difficult for abdominal procedures, and most of all because it allows for the

  19. Incision Below The Clamp sebagai Modifikasi Teknik Insisi pada Frenektomi untuk Minimalisasi Perdarahan

    Directory of Open Access Journals (Sweden)

    S. Suryono

    2016-10-01

    Full Text Available Latar Belakang. Perlekatan frenulum tinggi berdampak merugikan bagi jaringan periodontal maupun fungsi estetik. Perlekatan tinggi yang terjadi pada labialis superior, menimbulkan gingivitis dan sentral diastema yang menjadikan indikasi untuk dilakukan frenektomi. Frenektomi dengan teknik melakukan insisi di atas dan di bawah clamp berakibat lebarnya luka karena tarikan otot bibir, yang berdampak terjadi banyak perdarahan. Tujuan. Melakukan evaluasi terhadap modifikasi teknik insisi yang diharapkan dapat mengurangi perdarahan. Kasus dan Penanganan. Laporan kasus ini memaparkan penanganan kasus pada perlekatan frenulum tinggi yang diikuti adanya sentral diastema. Pasien dengan diagnosa frenulum tinggi dan indikasi frenektomi dilakukan tindakan preoperasi. Tindakan operasi dilakukan dengan menggunakan pisau bedah, modifikasi insisi (Insision below the Clamp dilakukan dengan cara menempatkan clamp frenulum pada posisi yang berdekatan dan sejajar dengan bibir, tindakan insisi dilakukan di bawah clamp, disusul dengan penjahitan pada area mucolabial fold. Selama operasi dilakukan terlihat luka tidak melebar, tidak banyak darah yang keluar, pasien dan dokter merasa nyaman. Kesimpulan. Insision below the Clamp merupakan modifikasi teknik insisi pada frenektomi yang bisa dilakukan oleh para praktisi untuk meminimalisir perdarahan yang terjadi selama proses pengambilan frenulum dengan menggunakan pisau bedah.   Background. Attachment of high frenulum has negative impact on periodontal tissues as well as an aesthetic function. High attachment of frenulum that occurs in labialis superior, causing gingivitis and central diastema that are indications to do Frenectomy. Conventional techniques of Frenectomy performed with insisions above and below the clamp resulted in wide injury due to muscle contraction, which affects a lot of bleeding. Objective. To evaluate modification insision technique which hopefully can minimize the bleeding. Case and Treatment. This

  20. Novel Low Loss Active Voltage Clamp Circuit for Series Connection of RCGCT thyristors

    Science.gov (United States)

    Ito, Hiroshi; Suzuki, Akihiro; Iwata, Akihiko

    This paper describes novel low loss active voltage clamp circuits for the series connection of RCGCT thyristors. For high voltage converters the series connection of power semiconductor devices is an essential technique for direct switching of high voltages. Several protection circuits have been applied to the series connection of RCGCT thyristors such as CRD snubber circuits which suppress over-voltages across RCGCT thyristors, and voltage balancing resistors to equalize voltage sharing in steady states. However, significant losses in these protection circuits lower the converter’s efficiency. We propose novel low-loss protection circuits, which have active voltage clamp snubber circuits and static voltage balancing circuits. The clamp capacitor voltage of the active voltage clamp snubber circuits are designed to be higher than the equally divided DC-Link voltage. This method can reduce the loss of the clamp circuit to no more than 1/10 of that of the conventional CRD snubber. Also the static voltage balancing circuits compensate for the voltage imbalance generated by the difference in the leakage current between the series connection RCGCT thyristors.

  1. Gain-clamping techniques in two-stage double-pass L-band EDFA

    Indian Academy of Sciences (India)

    S W harun; N Md Samsuri; H Ahmad

    2006-03-01

    Two designs of long-wavelength band erbium-doped fiber amplifier (L-band EDFA) for gain clamping in double-pass systems are demonstrated and compared. The first design is based on ring laser technique where a backward amplified spontaneous emission (ASE) from the second stage is routed into the feedback loop to create an oscillating laser for gain clamping. The gain is clamped at 18.6 dB from -40 to -8 dBm with a gain variation of less than ± 0.1 dB and a noise figure of less than 6 dB. Another scheme is based on partial reflection of ASE into the EDFA, which is demonstrated using a narrowband fiber Bragg grating. This scheme achieves a good gain clamping characteristic up to -12 dBm of input signal power with a gain variation of less than ± 0.3 dB from a clamped gain of 22 dB. The noise figure of a 1580 nm signal is maintained below 5 dB in this amplifier since this scheme is not based on lasing mechanism. The latter scheme is also expected to be free from the relaxation oscillation problem.

  2. Effect of timing of umbilical cord clamping of term infants on maternal and neonatal outcomes.

    Science.gov (United States)

    McDonald, Susan J; Middleton, Philippa; Dowswell, Therese; Morris, Peter S

    2013-07-11

    Policies for timing of cord clamping vary, with early cord clamping generally carried out in the first 60 seconds after birth, whereas later cord clamping usually involves clamping the umbilical cord more than one minute after the birth or when cord pulsation has ceased. The benefits and potential harms of each policy are debated. To determine the effects of early cord clamping compared with late cord clamping after birth on maternal and neonatal outcomes We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (13 February 2013). Randomised controlled trials comparing early and late cord clamping. Two review authors independently assessed trial eligibility and quality and extracted data. We included 15 trials involving a total of 3911 women and infant pairs. We judged the trials to have an overall moderate risk of bias. Maternal outcomes: No studies in this review reported on maternal death or on severe maternal morbidity. There were no significant differences between early versus late cord clamping groups for the primary outcome of severe postpartum haemorrhage (risk ratio (RR) 1.04, 95% confidence interval (CI) 0.65 to 1.65; five trials with data for 2066 women with a late clamping event rate (LCER) of ~3.5%, I(2) 0%) or for postpartum haemorrhage of 500 mL or more (RR 1.17 95% CI 0.94 to 1.44; five trials, 2260 women with a LCER of ~12%, I(2) 0%). There were no significant differences between subgroups depending on the use of uterotonic drugs. Mean blood loss was reported in only two trials with data for 1345 women, with no significant differences seen between groups; or for maternal haemoglobin values (mean difference (MD) -0.12 g/dL; 95% CI -0.30 to 0.06, I(2) 0%) at 24 to 72 hours after the birth in three trials. Neonatal outcomes: There were no significant differences between early and late clamping for the primary outcome of neonatal mortality (RR 0.37, 95% CI 0.04 to 3.41, two trials, 381 infants with a LCER of ~1%), or for most other

  3. Delayed Umbilical Cord Blood Clamping: First Line of Defense Against Neonatal and Age-Related Disorders.

    Science.gov (United States)

    Sanberg, Paul R; Divers, Ryan; Mehindru, Anuj; Mehindru, Ankur; Borlongan, Cesar V

    2014-06-01

    The aging body is unable to maintain homeostasis in cell genesis and function. Stem cell-based regenerative medicine may reverse aging and treat age-related disorders. This perspective article discusses the therapeutic effects of stem cell transplantation on neonatal diseases, which may have long-lasting benefits affecting even the aging process. In particular, the article highlights the potential of the earliest transfer of stem cells between a mother and fetus via the umbilical cord during child birth and how this process may modify the clinical practice of umbilical cord clamping. While such umbilical cord clamping is routinely performed in an expeditious manner after birth for stem cell banking, the present article advances the concept that a delay in clamping the umbilical cord may actually allow more stem cells to be delivered from the mother to the fetus. The authors' overarching hypothesis is that early umbilical cord clamping results in an artificial loss of stem cells at birth and increases the infant's susceptibility to both neonatal and age-related diseases, while delaying umbilical cord clamping is perhaps the most effective and non-invasive way to transplant stem cells in order to treat these diseases.

  4. Trail without Catheter after Transurethral Resection of Prostate: Clamp It or Not?

    Directory of Open Access Journals (Sweden)

    Vikash Talreja

    2016-01-01

    Full Text Available Background. There has been argument between clinical practitioners about clamping catheter or not prior to its removal after transurethral resection of prostate (TURP. We conducted a clinical trial to assess whether clamping has any role in early bladder tone recovery particularly in patients who undergo TURP. Methods. Randomized clinical trial was conducted at a tertiary care hospital, Karachi from January 2014 to July 2015. Eighty-six study participants who underwent TURP were randomly allocated into two groups of 43 participants each. In Group I, patient’s Foley catheter was not clamped prior to its removal and in Group II Foley catheter was clamped. Data of all subjects were analyzed using SPSS version 20. Results. There was no significant difference in age and weight of resected tissues between two groups. Among 4 patients in Group I who required recatheterization, 1 patient was discharged with catheter as compared to Group II in which 2 patients were discharged with catheter (P=0.99. Only 1 patient (2.3% in Group II had bleeding which required recatheterization. Length of stay was significantly affected by early and free removal of Foley catheter (P<0.001. Conclusion. The results of current study identified that clamping whether done or not had no significant impact on urinary retention.

  5. Functional dissection of synaptic circuits: in vivo patch-clamp recording in neuroscience

    Directory of Open Access Journals (Sweden)

    Can eTao

    2015-05-01

    Full Text Available Neuronal activity is dominated by synaptic inputs from excitatory or inhibitory neural circuits. With the development of in vivo patch-clamp recording, especially in vivo voltage-clamp recording, researchers can not only directly measure neuronal activity, such as spiking responses or membrane potential dynamics, but also quantify synaptic inputs from excitatory and inhibitory circuits in living animals. This approach enables researchers to directly unravel different synaptic components and to understand their underlying roles in particular brain functions. Combining in vivo patch-clamp recording with other techniques, such as two-photon imaging or optogenetics, can provide even clearer functional dissection of the synaptic contributions of different neurons or nuclei. Here, we summarized current applications and recent research progress using the in vivo patch-clamp recording method and focused on its role in the functional dissection of different synaptic inputs. The key factors of a successful in vivo patch-clamp experiment and possible solutions based on references and our experiences were also discussed.

  6. NRL-Regulated Transcriptome Dynamics of Developing Rod Photoreceptors.

    Science.gov (United States)

    Kim, Jung-Woong; Yang, Hyun-Jin; Brooks, Matthew John; Zelinger, Lina; Karakülah, Gökhan; Gotoh, Norimoto; Boleda, Alexis; Gieser, Linn; Giuste, Felipe; Whitaker, Dustin Thad; Walton, Ashley; Villasmil, Rafael; Barb, Jennifer Joanna; Munson, Peter Jonathan; Kaya, Koray Dogan; Chaitankar, Vijender; Cogliati, Tiziana; Swaroop, Anand

    2016-11-22

    Gene regulatory networks (GRNs) guiding differentiation of cell types and cell assemblies in the nervous system are poorly understood because of inherent complexities and interdependence of signaling pathways. Here, we report transcriptome dynamics of differentiating rod photoreceptors in the mammalian retina. Given that the transcription factor NRL determines rod cell fate, we performed expression profiling of developing NRL-positive (rods) and NRL-negative (S-cone-like) mouse photoreceptors. We identified a large-scale, sharp transition in the transcriptome landscape between postnatal days 6 and 10 concordant with rod morphogenesis. Rod-specific temporal DNA methylation corroborated gene expression patterns. De novo assembly and alternative splicing analyses revealed previously unannotated rod-enriched transcripts and the role of NRL in transcript maturation. Furthermore, we defined the relationship of NRL with other transcriptional regulators and downstream cognate effectors. Our studies provide the framework for comprehensive system-level analysis of the GRN underlying the development of a single sensory neuron, the rod photoreceptor. Published by Elsevier Inc.

  7. Thermal post-bunkling analyses of functionally graded material rod

    Institute of Scientific and Technical Information of China (English)

    ZHAO Feng-qun; WANG Zhong-min; LIU Hong-zhao

    2007-01-01

    The non-linear governing differential equations of immovably simply supported functionally graded material (FGM) rod subjected to thermal loads were derived.The thermal post-buckling behaviors of FGM rod made of ZrO2 and Ti-6A1-4Vwere analyzed by shooting method. Firstly, the thermal post-buckling equilibrium paths of the FGM rod with different gradient index in the uniform temperature field were plotted,and compared with the behaviors of the homogeneous rods made of ZrO2 and Ti-6A1-4V materials, respectively. For given value of end rotation angles, the influence of gradient index on the thermal post-buckling behaviors of FGM rod was discussed. Secondly, the thermal post-buckling characteristics of the FGM rod were analyzed when the temperature difference parameter is changed while the bottom temperature parameter remains constant, and when the bottom temperature parameter is changed while the temperature difference parameter remains constant, and compared with the characteristics of the two homogeneous material rods.

  8. Anisotropy in CdSe quantum rods

    Energy Technology Data Exchange (ETDEWEB)

    Li, Liang-shi

    2003-09-01

    The size-dependent optical and electronic properties of semiconductor nanocrystals have drawn much attention in the past decade, and have been very well understood for spherical ones. The advent of the synthetic methods to make rod-like CdSe nanocrystals with wurtzite structure has offered us a new opportunity to study their properties as functions of their shape. This dissertation includes three main parts: synthesis of CdSe nanorods with tightly controlled widths and lengths, their optical and dielectric properties, and their large-scale assembly, all of which are either directly or indirectly caused by the uniaxial crystallographic structure of wurtzite CdSe. The hexagonal wurtzite structure is believed to be the primary reason for the growth of CdSe nanorods. It represents itself in the kinetic stabilization of the rod-like particles over the spherical ones in the presence of phosphonic acids. By varying the composition of the surfactant mixture used for synthesis we have achieved tight control of the widths and lengths of the nanorods. The synthesis of monodisperse CdSe nanorods enables us to systematically study their size-dependent properties. For example, room temperature single particle fluorescence spectroscopy has shown that nanorods emit linearly polarized photoluminescence. Theoretical calculations have shown that it is due to the crossing between the two highest occupied electronic levels with increasing aspect ratio. We also measured the permanent electric dipole moment of the nanorods with transient electric birefringence technique. Experimental results on nanorods with different sizes show that the dipole moment is linear to the particle volume, indicating that it originates from the non-centrosymmetric hexagonal lattice. The elongation of the nanocrystals also results in the anisotropic inter-particle interaction. One of the consequences is the formation of liquid crystalline phases when the nanorods are dispersed in solvent to a high enough

  9. Coolant mixing in LMFBR rod bundles and outlet plenum mixing transients. Progress report, September 1, 1980-November 30, 1980

    Energy Technology Data Exchange (ETDEWEB)

    Todreas, N.E.; Golay, M.W.; Wolf, L.

    1981-02-01

    Four tasks are reported: bundle geometry (wrapped and bare rods), subchannel geometry (bare rods), subchannel geometry (bare rods), LMFBR outlet plenum flow mixing, and theoretical determination of local temperature fields in LMFBR fuel rod bundles. (DLC)

  10. The Effect of an Added Mass on the Frequency Shifts of a Clamped-Clamped Microbeam for Bio-Mass Detection

    KAUST Repository

    Bouchaala, Adam M.

    2016-12-05

    We present analytical formulations to calculate the induced resonance frequency shifts of electrically actuated clamped-clamped microbeams due to an added mass. Based on the Euler-Bernoulli beam theory, we investigate the linear dynamic responses of the beams added masses, which are modeled as discrete point masses. Analytical expressions based on perturbation techniques and a one-mode Galerkin approximation are developed to calculate accurately the frequency shifts under a DC voltage as a function of the added mass and position. The analytical results are compared to numerical solution of the eigenvalue problem. Results are shown for the fundamental as well as the higher-order modes of the beams. The results indicate a significant increase in the frequency shift, and hence the sensitivity of detection, when scaling down to nano scale and using higher-order modes.

  11. Treatment of defective fuel rods for interim storage

    Energy Technology Data Exchange (ETDEWEB)

    Muenchow, K.; Hummel, W. [AREVA NP GmbH, Erlangen (Germany)

    2013-07-01

    In this paper we look exclusively at the treatment of defective fuel rods for long-term dry interim storage at the nuclear power plant, in order to avoid off-site transports. AREVA has developed a technique that allows verifiably adequate drying of the defective fuel rods and reconstructs the barrier for retaining radioactive materials. This is done by individually encapsulating the defective fuel rods and achieving gas-tightness by seal welding. This guarantees the retention of radioactive materials during the storage period of at least 40 years in a transport and storage flask in an interim storage facility at site. (orig.)

  12. Gamma-ray spectroscopy on irradiated fuel rods

    Energy Technology Data Exchange (ETDEWEB)

    Terremoto, Luis Antonio Albiac [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Engenharia Nuclear], e-mail: laaterre@ipen.br

    2009-07-01

    The recording of gamma-ray spectra along an irradiated fuel rod allows the fission products to be qualitatively and quantitatively examined. Among all nondestructive examinations performed on irradiated fuel rods by gamma-ray spectroscopy, the most comprehensive one is the average burnup measurement, which is quantitative. Moreover, burnup measurements by means of gamma-ray spectroscopy are less time-consuming and waste-generating than burnup measurements by radiochemical, destructive methods. This work presents the theoretical foundations and experimental techniques necessary to measure, using nondestructive gamma-ray spectroscopy, the average burnup of irradiated fuel rods in a laboratory equipped with hot cells. (author)

  13. Axial gas flow in irradiated PWR fuel rods

    Energy Technology Data Exchange (ETDEWEB)

    Dagbjartsson, S.J.; Murdock, B.A.; Owen, D.E.; MacDonald, P.E.

    1977-09-01

    Transient and steady state axial gas flow experiments were performed on six irradiated, commercial pressurized water reactor fuel rods at ambient temperature and 533 K. Laminar flow equations, as used in the FRAP-T2 and SSYST fuel behavior codes, were used with the gas flow results to calculate effective fuel rod radial gaps. The results of these analyses were compared with measured gap sizes obtained from metallographic examination of one fuel rod. Using measured gap sizes as input, the SSYST code was used to calculate pressure drops and mass fluxes and the results were compared with the experimental gas flow data.

  14. Plasmonic rod dimers as elementary planar chiral meta-atoms

    CERN Document Server

    Zhukovsky, Sergei V; Chigrin, Dmitry N

    2011-01-01

    Electromagnetic response of metallic rod dimers is theoretically calculated for arbitrary planar arrangement of rods in the dimer. It is shown that dimers without an in-plane symmetry axis exhibit elliptical dichroism and act as "atoms" in planar chiral metamaterials. Due to a very simple geometry of the rod dimer, such planar metamaterials are much easier in fabrication than conventional split-ring or gammadion-type structures, and lend themselves to a simple analytical treatment based on coupled dipole model. Dependencies of metamaterial's directional asymmetry on the dimer's geometry are established analytically and confirmed in numerical simulations.

  15. 'Grounded' Politics

    DEFF Research Database (Denmark)

    Schmidt, Garbi

    2012-01-01

    play within one particular neighbourhood: Nørrebro in the Danish capital, Copenhagen. The article introduces the concept of grounded politics to analyse how groups of Muslim immigrants in Nørrebro use the space, relationships and history of the neighbourhood for identity political statements....... The article further describes how national political debates over the Muslim presence in Denmark affect identity political manifestations within Nørrebro. By using Duncan Bell’s concept of mythscape (Bell, 2003), the article shows how some political actors idealize Nørrebro’s past to contest the present...

  16. Phase diagram of colloid-rod system

    Science.gov (United States)

    Lai, S. K.; Xiao, Xuhui

    2010-01-01

    The semigrand ensemble theory [H. N. W. Lekkerkerker, W. C. K. Poon, P. N. Pusey, A. Stroobants, and P. B. Warren, Europhys. Lett. 20, 559 (1992)] in conjunction with the fundamental measure density functional theory [V. B. Warshavsky and X. Song, Phys. Rev. E 69, 061113 (2004)] are used to construct the Helmholtz free energy densities of a mixture of uncharged colloidal hard spheres and colloidal rods in its solid and liquid phases. Given these free energy density functions, we apply the free energy density minimization method [G. F. Wang and S. K. Lai, Phys. Rev. E 70, 051402 (2004)] to crosshatch the system's regions of phases in coexistence. The calculated results show that the triangular area bounded by gas-liquid, gas-solid, and liquid-solid coexisting two phases which has been called the coexistence region of gas-liquid-solid corresponds in fact to sets of two phases in coexistence. The phase boundaries which define our calculated coexistence domains compare very well with previous theoretical calculations. The relevance of the phase-diagram domains to three phases in coexistence will be discussed.

  17. Significance of Shrinkage Induced Clamping Pressure in Fiber-Matrix Bonding in Cementitious Composite Materials

    DEFF Research Database (Denmark)

    Stang, Henrik

    1996-01-01

    The present paper accesses the significance of shrinkage inducedclamping pressure in fiber/matrix bonding mechanisms incementitious composite materials. The paper contains a description of an experimental setup whichallows mbox{measurement} of the clamping pressure which develops on anelastic...... acting on any elastic inhomogeneityembedded in the same cementitious matrix material. Fiber-shaped inhomogeneities are of special interest in cementitious composite material systems andresults are presented for the development of clamping pressure on three typical fiber types in two typical cementpastes...... used in high performance cementitious composite materials.Assuming a Coulomb type of friction on the fiber/matrix interface andusing typical values for the frictional coefficient it is shownthat the shrinkage induced clamping pressure could be one of the mostimportant factors determining the frictional...

  18. Development of planar patch clamp technology and its application in the analysis of cellular electrophysiology

    Institute of Scientific and Technical Information of China (English)

    Peihua Chen; Wei Zhang; Jun Zhou; Ping Wang; Lidan Xiao; Mo Yang

    2009-01-01

    A patch clamp chip, as a novel cell-based chip for electrophysiological recordings, has many prominent advantages such as high res-olution, accuracy, high throughput and automation. It can be used to perform multivariate and real-time measurements of cell networks in situ. Therefore, this technology will dramatically promote the research on ionic channels, neuronal networks and the application of this technology in drug screening. This paper reviews the development of planar patch clamp technology and its applications in detail. The latest progress in the research of taste cells electrophysiology and taste transduction is also presented. Finally, this paper analyzes the methodology of neural chips. Based on the current research of our laboratory, the prospective applications of a patch clamp chip in the research of taste sensation and transduction mechanisms at molecular and cellular levels are discussed.

  19. Flange joint system for SRF cavities utilizing high force spring clamps for low particle generation

    Energy Technology Data Exchange (ETDEWEB)

    None

    2017-09-05

    A flange joint system for SRF cavities. The flange joint system includes a set of high force spring clamps that produce high force on the simple flanges of Superconducting Radio Frequency (SRF) cavities to squeeze conventional metallic seals. The system establishes the required vacuum and RF-tight seal with minimum particle contamination to the inside of the cavity assembly. The spring clamps are designed to stay within their elastic range while being forced open enough to mount over the flange pair. Upon release, the clamps have enough force to plastically deform metallic seal surfaces and continue to a new equilibrium sprung dimension where the flanges remain held against one another with enough preload such that normal handling will not break the seal.

  20. Enhancing endogenous stem cells in the newbornvia delayed umbilical cord clamping

    Institute of Scientific and Technical Information of China (English)

    Christopher Lawton; Sandra Acosta; Nate Watson; Chiara Gonzales-Portillo; hTeo Diamandis; Naoki Tajiri; Yuji Kaneko; Paul R. Sanberg; Cesar V. Borlongan

    2015-01-01

    There is currently no consensus among clinicians and scientists over the appropriate or optimal timing for umbilical cord clamping. However, many clinical studies have suggested that delayed cord clamping is associated with various neonatal beneifts including increased blood volume, reduced need for blood transfusion, increased cerebral oxygenation in pre-term infants, and decreased frequency of iron deifciency anemia in term infants. Human umbilical cord blood con-tains signiifcant amounts of stem and progenitor cells and is currently used in the treatment of several life-threatening diseases. We propose that delayed cord clamping be encouraged as it en-hances blood lfow from the placenta to the neonate, which is accompanied by an increase supply of valuable stem and progenitor cells, as well as may improve blood oxygenation and increase blood volume, altogether reducing the infant’s susceptibility to both neonatal and age-related diseases.

  1. [Focus on placental transfusion for preterm neonates: Delayed cord clamping and/or milking?

    Science.gov (United States)

    Sorin, G; Tosello, B

    2016-11-01

    Anemia of prematurity remains a common complication despite recent advances in perinatal and neonatal medicine. The delayed cord clamping (at least 30seconds as recommended) has several benefits: increased hemoglobin and hematocrit levels at birth, improved initial hemodynamic, decreased incidence of transfusions and intraventricular hemorrhages. When the birth transition is difficult, wait 30seconds before clamping can be impossible. So as not to interfere with the neonatal resuscitation, the "milking" has been proposed as an alternative method to the delayed cord clamping. This is a safe and easy method, which can be done either by an obstetrician or pediatrician with comparable results for the child on his hemodynamic, hematological and neurological status. It still lacks technical information on this method and neurodevelopmental outcomes of these preterm infants. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  2. Enhancing endogenous stem cells in the newborn via delayed umbilical cord clamping

    Directory of Open Access Journals (Sweden)

    Christopher Lawton

    2015-01-01

    Full Text Available There is currently no consensus among clinicians and scientists over the appropriate or optimal timing for umbilical cord clamping. However, many clinical studies have suggested that delayed cord clamping is associated with various neonatal benefits including increased blood volume, reduced need for blood transfusion, increased cerebral oxygenation in pre-term infants, and decreased frequency of iron deficiency anemia in term infants. Human umbilical cord blood contains significant amounts of stem and progenitor cells and is currently used in the treatment of several life-threatening diseases. We propose that delayed cord clamping be encouraged as it enhances blood flow from the placenta to the neonate, which is accompanied by an increase supply of valuable stem and progenitor cells, as well as may improve blood oxygenation and increase blood volume, altogether reducing the infant′s susceptibility to both neonatal and age-related diseases.

  3. Enhancing endogenous stem cells in the newborn via delayed umbilical cord clamping.

    Science.gov (United States)

    Lawton, Christopher; Acosta, Sandra; Watson, Nate; Gonzales-Portillo, Chiara; Diamandis, Theo; Tajiri, Naoki; Kaneko, Yuji; Sanberg, Paul R; Borlongan, Cesar V

    2015-09-01

    There is currently no consensus among clinicians and scientists over the appropriate or optimal timing for umbilical cord clamping. However, many clinical studies have suggested that delayed cord clamping is associated with various neonatal benefits including increased blood volume, reduced need for blood transfusion, increased cerebral oxygenation in pre-term infants, and decreased frequency of iron deficiency anemia in term infants. Human umbilical cord blood contains significant amounts of stem and progenitor cells and is currently used in the treatment of several life-threatening diseases. We propose that delayed cord clamping be encouraged as it enhances blood flow from the placenta to the neonate, which is accompanied by an increase supply of valuable stem and progenitor cells, as well as may improve blood oxygenation and increase blood volume, altogether reducing the infant's susceptibility to both neonatal and age-related diseases.

  4. Sequential dissection of multiple ionic currents in single cardiac myocytes under action potential-clamp.

    Science.gov (United States)

    Banyasz, Tamas; Horvath, Balazs; Jian, Zhong; Izu, Leighton T; Chen-Izu, Ye

    2011-03-01

    The cardiac action potential (AP) is shaped by myriad ionic currents. In this study, we develop an innovative AP-clamp Sequential Dissection technique to enable the recording of multiple ionic currents in the single cell under AP-clamp. This new technique presents a significant step beyond the traditional way of recording only one current in any one cell. The ability to measure many currents in a single cell has revealed two hitherto unknown characteristics of the ionic currents in cardiac cells: coordination of currents within a cell and large variation of currents between cells. Hence, the AP-clamp Sequential Dissection method provides a unique and powerful tool for studying individual cell electrophysiology.

  5. FUNDAMENTAL RESONANCE AND BIFURCATION OF LARGE GENERATOR END WINDING WHEN ITS CLAMPING PLATES ARE LOOSE

    Institute of Scientific and Technical Information of China (English)

    HU Yu-da; QIU Jia-jun; TA Na

    2005-01-01

    Vibration problems of a segment of winding between two clamping plates are studied when the clamping plates, which are used to fix stator end winding, are loose. First,magnetic induction expressions of the winding while the generator was running were given by using separation of variables method. Also, the expressions of the winding electromagnetic force and dry friction force between loosing clamping plates were gotten. Secondly, a mechanical model, which was used to study nonlinear vibration problem of the winding, was set up. Fundamental resonance was analyzed by using multiple scales method, and a resonance equation of amplitude and frequency in steady state was given. Then stability,bifurcation and singularity of the steady solution were studied. Criterions of stability and transition set of the bifurcation equation were obtained. At last, through numerical calculations, resonance curves were obtained. The results are helpful for analysis and protection of generator accidents.

  6. Minimum Normal Force Principle Based Quantitive Optimizationof Clamping Forces for Thin Walled Part

    Institute of Scientific and Technical Information of China (English)

    ZHANG Fa-ping; SUN Hou-fang; SHAHID I.Butt

    2008-01-01

    Based on the stability criteria of workpiece-fixture system, quantitative optimization of clamping forces during precise machining process for thin walled part is studied considering the contact condition between wokpiece and locator, the contact mechanical model is achieved ,which is further been used to calculate the entire passive forces acting on the statically undetermined workpiece by means of the force screw theory as well as minimum norm force principle. Furthermore, a new methodology to optimize clamping forces is put forward, on the criteria of keeping the stability of workpiece during cutting process. By this way, the intensity of clamping forces is decreased dramatically, which will be most beneficial for improving the machining quality of thin-walled parts. Finally, a case study is used to support and validate the proposed model.

  7. Comparison of herniorrhaphy versus clamping of umbilical hernias in horses: a retrospective study of 93 cases (1982-1994).

    OpenAIRE

    1996-01-01

    Many uncomplicated umbilical hernias have been managed successfully in foals by the application of a hernia clamp. Isolated reports of complications following clamp application have led some authors to suggest that it is an unsuitable method of treatment. Little information has been published comparing the complication rates associated with the use of hernia clamps and herniorrhaphy in the treatment of umbilical hernias. The purpose of this retrospective study was to report the characteristic...

  8. [Delayed umbilical cord clamping in preterm infants born before 37 weeks of gestation: A prospective observational study].

    Science.gov (United States)

    Dicky, O; Ehlinger, V; Guyard-Boileau, B; Assouline, C; Arnaud, C; Casper, C

    2017-02-01

    Many international studies have demonstrated that delayed umbilical cord clamping reduces neonatal morbidity. However, in France, delayed umbilical cord clamping is still not performed in many neonatal units. The aims of this study were to evaluate the feasibility of developing a protocol of delayed umbilical cord clamping in the maternity ward of the Toulouse university hospital and to evaluate the impact of this new protocol on neonatal mortality. We conducted a prospective observational study including 123 preterm infants born before 37 weeks of gestation between June 2012 and June 2013 and hospitalized at birth. Delayed cord clamping was performed for at least 30s after birth; otherwise, it was evaluated as early cord clamping. We excluded twin-to-twin transfusion syndrome, congenital abnormalities, alloimmunization, and perinatal asphyxia. We analyzed the reasons why delayed umbilical cord clamping was not performed and then neonatal morbidity in our population. Delayed umbilical cord clamping was performed on 79 infants and 44 infants had early umbilical cord clamping. The two groups had similar baseline characteristics. Preterm infants in the delayed cord-clamping group had a higher level of hemoglobin during the first 24h of life (17.9g/dL versus 16.6g/dL, P=0.005), fewer of them required transfusion (14% versus 35%, P=0.03), and fewer presented late-onset sepsis (8% versus 26%, P=0.02) or bronchopulmonary dysplasia (9% versus 26%, P=0.03). There was no statistically significant increase of hyperbilirubinemia requiring phototherapy. Implanting a new protocol of delayed umbilical cord clamping in our maternity ward proved to be possible without difficulty. The advantages of delayed umbilical cord clamping were observed in this prospective study. Today, delayed cord clamping has become a common practice in our maternity unit. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  9. Modified Blalock clamp: a single-hand autostatic device for pulmonary vessel occlusion during lung cancer resection

    OpenAIRE

    Petrella, Francesco; Solli, Piergiorgio; Borri, Alessandro; Spaggiari, Lorenzo

    2011-01-01

    Vascular clamping during lung cancer resection may be difficult in patients with short vessels or large neoplasms preventing adequate and safe exposure. In addition, the physiological vicinity of some vessels to rigid structures like the bronchi may interfere with ideal clamp positioning even in ordinary procedures. We have modified the original Blalock clamp to facilitate the control of pulmonary vessels and physiologically compress the vessel walls, thereby allowing optimal vascular resecti...

  10. Force-extension curves for broken-rod macromolecules: Dramatic effects of different probing methods for two and three rods

    Energy Technology Data Exchange (ETDEWEB)

    Alexeev, A. V.; Maltseva, D. V.; Ivanov, V. A., E-mail: ivanov@polly.phys.msu.ru [Faculty of Physics, Moscow State University, 119991 Moscow (Russian Federation); Klushin, L. I., E-mail: leo@aub.edu.lb [Department of Physics, American University of Beirut, P.O. Box 11-0236, Beirut 1107 2020 (Lebanon); Skvortsov, A. M., E-mail: astarling@yandex.ru [Chemical-Pharmaceutical Academy, Prof. Popova 14, 197022 St. Petersburg (Russian Federation)

    2015-04-28

    We study force-extension curves of a single semiflexible chain consisting of several rigid rods connected by flexible spacers. The atomic force microscopy and laser optical or magnetic tweezers apparatus stretching these rod-coil macromolecules are discussed. In addition, the stretching by external isotropic force is analyzed. The main attention is focused on computer simulation and analytical results. We demonstrate that the force-extension curves for rod-coil chains composed of two or three rods of equal length differ not only quantitatively but also qualitatively in different probe methods. These curves have an anomalous shape for a chain of two rods. End-to-end distributions of rod-coil chains are calculated by Monte Carlo method and compared with analytical equations. The influence of the spacer’s length on the force-extension curves in different probe methods is analyzed. The results can be useful for interpreting experiments on the stretching of rod-coil block-copolymers.

  11. Large-eddy simulation, fuel rod vibration and grid-to-rod fretting in pressurized water reactors

    Science.gov (United States)

    Christon, Mark A.; Lu, Roger; Bakosi, Jozsef; Nadiga, Balasubramanya T.; Karoutas, Zeses; Berndt, Markus

    2016-10-01

    Grid-to-rod fretting (GTRF) in pressurized water reactors is a flow-induced vibration phenomenon that results in wear and fretting of the cladding material on fuel rods. GTRF is responsible for over 70% of the fuel failures in pressurized water reactors in the United States. Predicting the GTRF wear and concomitant interval between failures is important because of the large costs associated with reactor shutdown and replacement of fuel rod assemblies. The GTRF-induced wear process involves turbulent flow, mechanical vibration, tribology, and time-varying irradiated material properties in complex fuel assembly geometries. This paper presents a new approach for predicting GTRF induced fuel rod wear that uses high-resolution implicit large-eddy simulation to drive nonlinear transient dynamics computations. The GTRF fluid-structure problem is separated into the simulation of the turbulent flow field in the complex-geometry fuel-rod bundles using implicit large-eddy simulation, the calculation of statistics of the resulting fluctuating structural forces, and the nonlinear transient dynamics analysis of the fuel rod. Ultimately, the methods developed here, can be used, in conjunction with operational management, to improve reactor core designs in which fuel rod failures are minimized or potentially eliminated. Robustness of the behavior of both the structural forces computed from the turbulent flow simulations and the results from the transient dynamics analyses highlight the progress made towards achieving a predictive simulation capability for the GTRF problem.

  12. Results of Post Irradiation Examinations of VVER Leaky Rods

    Energy Technology Data Exchange (ETDEWEB)

    Markov, D.; Perepelkin, S.; Polenok, V.; Zhitelev, V.; Mayorshina, G. [Head of Fuel Research Department, JSC ' SSC RIAR' , 433510, Dimitrovgrad-10, Ulyanovsk region (Russian Federation)

    2009-06-15

    The most important requirement imposed on fuel elements is to maintain integrity of fuel rod claddings under operation, storage and transportation, since it is directly related to the operational safety. However, failed rod claddings are sometimes observed under reactor operation. Identification and unloading of fuel assemblies with leaky rods from VVER is available only at the time of planned preventive maintenance. An unscheduled reactor shutdown due to the excess of coolant activity limit as well as a preterm unloading of the fuel assembly cause economic damage to nuclear plant. Therefore, models and calculation codes were developed to forecast coolant contamination and failed fuel rod behavior. Criteria based on calculations were set to determine the admissible number of the failed rods in core and the opportunity to continue the reactor operation or pre-term unloading of the fuel assembly with the failed rods. Nevertheless, to prevent the fuel rod failure (for unfailing operation) it is necessary to reveal disadvantages of the design, fabrication method and fuel operation conditions, and to eliminate defects. The most complete and significant information about spent fuel assemblies may be received following the post irradiation material examinations. In order to reveal failure origins and mechanism of changes in VVER fuel and failed rod cladding condition depending on the operation, the examinations of 12 VVER-1000 fuel assemblies and 3 VVER-440 fuel assemblies, operated under normal conditions up to the fuel burnup 13..47 MWd/kgU were carried out. To evaluate the rod cladding condition, reveal defects and determine their parameters, the ultrasonic control of cladding integrity, surface visual inspection, eddy current defectoscopy, measurement of geometrical parameters were applied. In separate cases we used the metallography, measured the hydrogen percentage and carried out the mechanical tests of o-ring samples. The pellet condition was evaluated in

  13. Can robots patch-clamp as well as humans? Characterization of a novel sodium channel mutation.

    Science.gov (United States)

    Estacion, M; Choi, J S; Eastman, E M; Lin, Z; Li, Y; Tyrrell, L; Yang, Y; Dib-Hajj, S D; Waxman, S G

    2010-06-01

    Ion channel missense mutations cause disorders of excitability by changing channel biophysical properties. As an increasing number of new naturally occurring mutations have been identified, and the number of other mutations produced by molecular approaches such as in situ mutagenesis has increased, the need for functional analysis by patch-clamp has become rate limiting. Here we compare a patch-clamp robot using planar-chip technology with human patch-clamp in a functional assessment of a previously undescribed Nav1.7 sodium channel mutation, S211P, which causes erythromelalgia. This robotic patch-clamp device can increase throughput (the number of cells analysed per day) by 3- to 10-fold. Both modes of analysis show that the mutation hyperpolarizes activation voltage dependence (8 mV by manual profiling, 11 mV by robotic profiling), alters steady-state fast inactivation so that it requires an additional Boltzmann function for a second fraction of total current (approximately 20% manual, approximately 40% robotic), and enhances slow inactivation (hyperpolarizing shift--15 mV by human,--13 mV robotic). Manual patch-clamping demonstrated slower deactivation and enhanced (approximately 2-fold) ramp response for the mutant channel while robotic recording did not, possibly due to increased temperature and reduced signal-to-noise ratio on the robotic platform. If robotic profiling is used to screen ion channel mutations, we recommend that each measurement or protocol be validated by initial comparison to manual recording. With this caveat, we suggest that, if results are interpreted cautiously, robotic patch-clamp can be used with supervision and subsequent confirmation from human physiologists to facilitate the initial profiling of a variety of electrophysiological parameters of ion channel mutations.

  14. Umbilical blood flow patterns directly after birth before delayed cord clamping.

    Science.gov (United States)

    Boere, I; Roest, A A W; Wallace, E; Ten Harkel, A D J; Haak, M C; Morley, C J; Hooper, S B; te Pas, A B

    2015-03-01

    Delayed umbilical cord clamping (DCC) affects the cardiopulmonary transition and blood volume in neonates immediately after birth. However, little is known of blood flow in the umbilical vessels immediately after birth during DCC. The objective is to describe the duration and patterns of blood flow through the umbilical vessels during DCC. Arterial and venous umbilical blood flow was measured during DCC using Doppler ultrasound in uncomplicated term vaginal deliveries. Immediately after birth, the probe was placed in the middle of the umbilical cord, pattern and duration of flow in vein and arteries were evaluated until cord clamping. Thirty infants were studied. Venous flow: In 10% no flow was present, in 57% flow stopped at 4:34 (3:03-7:31) (median (IQR) min:sec) after birth, before the cord was clamped. In 33%, flow continued until cord clamping at 5:13 (2:56-9:15) min:sec. Initially, venous flow was intermittent, increasing markedly during large breaths or stopping and reversing during crying, but then became continuous. Arterial flow: In 17% no flow was present, in 40% flow stopped at 4:22 (2:29-7:17) min:sec, while cord pulsations were still palpable. In 43% flow continued until the cord was clamped at 5:16 (3:32-10:10) min:sec. Arterial flow was pulsatile, unidirectional towards placenta or bidirectional to/from placenta. In 40% flow became continuous towards placenta later on. During delayed umbilical cord clamping, venous and arterial umbilical flow occurs for longer than previously described. Net placental transfusion is probably the result of several factors of which breathing could play a major role. Umbilical flow is unrelated to cessation of pulsations. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  15. Alternative positions for the baby at birth before clamping the umbilical cord.

    Science.gov (United States)

    Airey, Rebecca J; Farrar, Diane; Duley, Lelia

    2010-10-06

    The third stage of labour is from birth of the baby until delivery of the placenta. Clamping the umbilical cord is one component of active management of the third stage. Deferring cord clamping allows blood flow between the baby and the placenta to continue; net transfer to the baby is called placental transfusion. If the cord is clamped immediately placental transfusion is restricted. Gravity is one of several factors that may influence the volume and duration of placental transfusion at both vaginal and caesarean births. Hence raising or lowering the baby whilst the cord is intact may influence placental transfusion, which in turn may affect outcome for the baby and the woman. To compare the effects of alternative positions for the baby between birth and cord clamping on outcome for the baby, outcome for the mother and on use of health service resources. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (July 2010). Randomised trials comparing alternative positions for the baby at vaginal and caesarean birth, before clamping of the umbilical cord. We independently assessed trial eligibility and quality. When necessary, we contacted study authors for additional information. Thirty-seven studies (7559 mother-infant pairs) were excluded: 33 (7296) because they did not compare alternative positions for the baby before clamping the umbilical cord and four (263) due to quasi-random allocation. No studies met the inclusion criteria. One additional trial is ongoing. No randomised trials have assessed the influence of gravity on placental transfusion. Large, well-designed randomised trials are needed to assess whether gravity influences placental transfusion at vaginal and caesarean births and, if so, whether this affects short-term and long-term outcome for the baby and for the mother.

  16. Design and fabrication of a planar patch-clamp substrate using a silicon-on-insulator wafer

    Science.gov (United States)

    Zhenlong, Zhang; Xiangyang, Liu; Yanli, Mao

    2009-09-01

    The planar patch-clamp technique has been applied to high throughput screening in drug discovery. The key feature of this technique is the fabrication of a planar patch-clamp substrate using appropriate materials. In this study, a planar patch-clamp substrate was designed and fabricated using a silicon-on-insulator (SOI) wafer. The access resistance and capacitance of SOI-based planar patch-clamp substrates are smaller than those of bulk silicon-based planar substrates, which will reduce the distributed RC noise.

  17. Clamping drainage is unnecessary after minimally invasive total knee arthroplasty in patients with tranexamic acid

    Science.gov (United States)

    Wu, Yuangang; Yang, Timin; Zeng, Yi; Li, Canfeng; Shen, Bin; Pei, Fuxing

    2017-01-01

    Abstract Background: Drainage and tranexamic acid (TXA) have been widely used in total knee arthroplasty (TKA). However, it remains unclear whether it is necessary to clamp the drain after minimally invasive TKA (MIS-TKA) when TXA is used. We therefore conducted a randomized controlled trial to compare the effects of clamping versus not clamping drainage following MIS-TKA in patients in whom TXA was used. Methods: From January 2015 to December 2015, 121 patients undergoing unilateral primary MIS-TKA were enrolled and randomly divided into 2 groups. In the clamping group (N = 60), drainage was clamped for the 1st 4 postoperative hours. In the nonclamping group (N = 61), drainage was not clamped. All patients underwent a minimidvastus approach and received 10 mg/kg TXA intravenously before tourniquet deflation. We recorded the total blood loss, drainage volume, and transfusion requirements in the postoperative period. We also measured the hemoglobin (Hb) and hematocrit (Hct) levels on postoperative days 1, 3, and 5. Other factors, including range of motion (ROM), visual analog scale (VAS), and occurrence of wound-related complications, deep vein thrombosis (DVT), and pulmonary embolism (PE) were recorded at the time of discharge and 1 and 6 months postoperatively. No statistically significant differences were found between the 2 groups with regard to age, gender, weight, BMI, preoperative Hb and Hct levels, preoperative ROM, VAS, duration of surgery, anesthesia method, and the American Society of Anesthesiologists classification. Results: The clamping group experienced better drainage volume results than the nonclamping group (P < 0.001). There were no statistically significant differences in TBL and transfusion requirements (P = 0.105 and 0.276, respectively); Hb and Hct levels on postoperative days 1, 3, and 5 were similar between the 2 groups. No significant differences were found for ROM, VAS, DVT, PE, wound-related complications, and hospital

  18. In vivo patch clamp recording technique in the study of neurophysiology

    Institute of Scientific and Technical Information of China (English)

    Lan-Wei CUI; Yu-Rong LI

    2006-01-01

    The patch clamp recording technique in vivois a blind patch clamp recording methods to record the current of the spinal or cereral neurons of anaesthesia ( or awake) animals. This technique can be used to study the synaptic function and plasticity in central nervous system in vivoin order to understand the physiological properties of the ion channels from an integrated point of view. The advantage of this technique have already presented itself in the study of the synaptic transmission and nervous network. Nowadays, in vivo patch whole-cell recording technique in combination with other techniques is becoming a common method in the research fields.

  19. Cerebral oxygenation and processed EEG response to clamping and shunting during carotid endarterectomy under general anesthesia.

    Science.gov (United States)

    Perez, William; Dukatz, Christopher; El-Dalati, Sami; Duncan, James; Abdel-Rasoul, Mahmoud; Springer, Andrew; Go, Michael R; Dzwonczyk, Roger

    2015-12-01

    Clamping and shunting during carotid endarterectomy (CEA) surgery causes changes in cerebral blood flow. The purpose of this study was to assess and compare, side by side, the cerebral oxygenation (rSO2) and processed electroencephalogram (EEG) response bilaterally to carotid artery clamping and shunting in patients undergoing CEA under general anesthesia. With institutional approval and written informed consent, patients undergoing CEA under general anesthesia and routine carotid artery shunting were recorded bilaterally, simultaneously and continuously with an rSO2 and processed EEG monitor. The response of the monitors during carotid artery clamping and shunting were assessed and compared between monitors and bilaterally within each monitor. Sixty-nine patients were included in the study. At clamping the surgical-side and contralateral-side rSO2 dropped significantly below the baseline incision value (-17.6 and -9.4% respectively). After shunting, the contralateral-side rSO2 returned to baseline while the surgical-side rSO2 remained significantly below baseline (-9.0%) until the shunt was removed following surgery. At clamping the surgical-side and contralateral-side processed EEG also dropped below baseline (-19.9 and -20.6% respectively). However, following shunt activation, the processed EEG returned bilaterally to baseline. During the course of this research, we found the rSO2 monitor to be clinically more robust (4.4% failure rate) than the processed EEG monitor (20.0% failure rate). There was no correlation between the rSO2 or processed EEG changes that occurred immediately after clamping and the degree of surgical side stenosis measured pre-operatively. Both rSO2 and processed EEG respond to clamping and shunting during CEA. Cerebral oximetry discriminates between the surgical and contralateral side during surgery. The rSO2 monitor is more reliable in the real-world clinical setting. Future studies should focus on developing algorithms based on these

  20. Discussion on compact mechanism of air-stream and synchro-formed clamp plate impact molding

    Directory of Open Access Journals (Sweden)

    Zhenling WANG

    2004-11-01

    Full Text Available Applying the air impact molding method to mold the complicated pattern with wider opening surface and deeper concave, there always exist vaulted phenomenon and lower compactibility of sand mold over the entrance and the concave regions. Using the air-stream and synchro-formed clamp plate impact molding, however, this problem will be preferably solved. In this paper, the compact mechanism of the new molding method and the effect of some configuration factors, such as the area flowed by compressed air and the highness of the protruding block displacement around the diffluent clamp plate, on the compactibility of sand mold were discussed.

  1. Experience of application of clamp-on cross-correlation flow meter in nuclear industry

    Energy Technology Data Exchange (ETDEWEB)

    Gurevich, Y. [Daystar Technology Inc., Ontario (Canada); Ton, V.; Kotenyov, S.; Zhao, C. [Ontario Power Generation, Ontario (Canada); Sharp, B.; Lopez, A. [Advanced Measurements and Analysis Group Inc., Ontario (Canada)

    2010-07-01

    The cross-correlation clamp-on flow meter, CROSSFLOW, developed and manufactured by AMAG, has been used over the world for over 15 years for flow measurements in various systems in nuclear and fossil power plants. Prior that, OPG has used similar technology in Canadian nuclear power plants since 1980-ies. Two recent examples of the application of the clamp-on cross-correlation technology are presented in this paper. In first example OPG meter was used to verify accuracy of ASME nozzles installed in condensate flow lines. In second example AMAG meter was used to measure Diesel Cooling Water (DCW). (author)

  2. High-yield production of hydrophobins RodA and RodB from Aspergillus fumigatus in Pichia pastoris

    DEFF Research Database (Denmark)

    Pedersen, Mona Højgaard; Borodina, Irina; Moresco, Jacob Lange

    2011-01-01

    B on the surface of its conidia. RodA is known to be of importance to the pathogenesis of the fungus, while the biological role of RodB is currently unknown. Here, we report the successful expression of both hydrophobins in Pichia pastoris and present fed-batch fermentation yields of 200–300 mg/l fermentation...... broth. Protein bands of expected sizes were detected by SDS-PAGE and western blotting, and the identity was further confirmed by tandem mass spectrometry. Both proteins were purified using his-affinity chromatography, and the high level of purity was verified by silver-stained SDS-PAGE. Recombinant Rod...

  3. Site-specific growth of polymers on silica rods.

    Science.gov (United States)

    Peng, Bo; Soligno, Giuseppe; Kamp, Marlous; de Nijs, Bart; de Graaf, Joost; Dijkstra, Marjolein; van Roij, René; van Blaaderen, Alfons; Imhof, Arnout

    2014-12-28

    Colloids specifically developed for self-assembly (SA) into advanced functional materials have rapidly become more complex, as this complexity allows for more ways to optimize both the SA process and the properties of the resulting materials. For instance, by creating 'patchy' particles more open structures can be achieved through directional interactions. However, the number of ways in which site-specific chemistry can be achieved on particle surfaces is still limited. Here, we show how polymer patches can be specifically grown onto only the flat end of bullet-shaped silica rods by utilizing a subtle anisotropy in surface tension and shape caused by the growth mechanism of the rods. Conversely, if the bullet-shaped silica rods are used as 'Pickering-emulsion' stabilizers the same surface tension effects exclusively direct the orientation of the rods into a 'hedgehog-morphology'. Finally, we demonstrate how an external electric field can direct the particles in a 'vectorial' way.

  4. Development of visual and tactile rod orientation in children.

    Science.gov (United States)

    Meerwaldt, J D; Schmitz, P I

    1988-09-15

    Two groups of neurologically normal children (total number 64), aged from 4 to 13 years, were examined with the rod orientation test. In the second group, the line orientation test and finger tapping were also studied in addition to the rod orientation test. On the rod orientation test, the mean error rates decreased with age in both groups, and from the age of 10 the children performed as well as normal adults. In the period (ages 4-7 years) in which the greatest change in performance on the visual part of the rod orientation test had taken place (63%), a much smaller change occurred in the tapping frequency (23%). Thus the development of motor skills does not seem to be directly related to the development of spatial perception. The line orientation test did not show any developmental profile.

  5. Design requirement on KALIMER control rod assembly duct

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, W.; Kang, H. Y.; Nam, C.; Kim, J. O.; Kim, Y. J

    1998-03-01

    This document establishes the design guidelines which are needs for designing the control rod assembly duct of the KALIMER as design requirements. it describes control rod assembly duct of the KALIMER and its requirements that includes functional requirements, performance requirements, interfacing systems, design limits and strength requirements, seismic requirements, structural requirements, environmental requirements, reliability and safety requirements, standard and codes, QA programs, and other requirements. The control rod system consists of three parts, which are drive mechanism, drive-line, and absorber bundle. This report deals with the absorber bundle and its outer duct only because the others are beyond the scope of fuel system design. The guidelines for design requirements intend to be used for an improved design of the control rod assembly duct of the KALIMER. (author). 19 refs.

  6. Rod-shaped carbon isotopes at extreme spin and isopin

    CERN Document Server

    Zhao, P W; Meng, J

    2014-01-01

    The anomalously deformed rod shape has been investigated in the framework of the cranking covariant density functional theory, and two mechanisms to stabilize such state with respect to the bending motion, extreme spin and isospin, are simultaneously discussed for the first time in a self-consistent and microscopic way. It has been known that adding valence neutrons and rotating the system play very important roles in the stability of the rod shape, and we have found their coherent effect; the sigma-orbitals (parallel to the symmetry axis) of the valence neutrons, important for the rod shape, are lowered by the rotation due to the Coriolis term. This provides a further strong hint that a rod shape could be realized in nuclei towards extreme spin and isopin.

  7. On the resonant behavior of longitudinally vibrating accreting rods

    CSIR Research Space (South Africa)

    Shatalov, M

    2012-09-01

    Full Text Available The theory of accreting structures is a new and fast developing branch of analytical mechanics basing on the theory of partial differential and integral equations. In the present paper the authors analyze qualitative properties of accreting rods...

  8. Control of rod shedding in the frog retina.

    Science.gov (United States)

    Basinger, S F; Hollyfield, J G

    1980-01-01

    In all vertebrate species examined thus far, rod outer segment shedding follows a cyclic pattern in which the outer segment tips are shed shortly after the onset of light. Work in the rat retina suggests that rod shedding may follow a circadian rhythm which is controlled by one or more circadian oscillators. Our results in the frog retina are significantly different in that: rod shedding can be driven by the onset of light or other environmental cues; shedding does not persist in constant darkness; shedding is unaffected in frogs with chronic unilateral or bilateral optic nerve section; and shedding will rapidly phase shift to the time of light onset on a wide variety of diurnal cycles. Thus, rod shedding in the frog retina does not appear to be a classical circadian rhythm.

  9. Remotely operated gripper provides vertical control rod movement

    Science.gov (United States)

    Hutter, E.; Koch, L. J.

    1968-01-01

    Remote actuation of a gripper shaft affects vertical engagement between a drive shaft and control rod. A secondary function of the gripper is to provide remote indication of positive completion of the gripping or ungripping operation.

  10. Ultrasonic detection of cracks in uniaxial glass fibre rods

    CSIR Research Space (South Africa)

    Loveday, PW

    2006-01-01

    Full Text Available A non-destructive examination procedure based on a guided wave inspection approach is used for the acoustic examination of glass fibre reinforced composite rods. This paper contains an investigation into the characteristics of guided wave...

  11. Oscillation of a rigid rod in the special relativity

    CERN Document Server

    Paiva, F M

    2012-01-01

    In the special relativity, a rigid rod slides upon itself, with one extremity oscillating harmonically. We discovered restrictions in the amplitude of the motion and in the length of the rod, essential to eliminate unphysical solutions. ------- Cxe la speciala relativeco, rigida stango movigxas sur si mem, kun unu fino oscilante harmonie. Ni malkovris limigajn kondicxojn pri la amplitudo de movado kaj pri la longo de stango, necesegaj por elimini ne-fizikajn solvojn.

  12. Double-clad nuclear-fuel safety rod

    Science.gov (United States)

    McCarthy, W.H.; Atcheson, D.B.

    1981-12-30

    A device for shutting down a nuclear reactor during an undercooling or overpower event, whether or not the reactor's scram system operates properly. This is accomplished by double-clad fuel safety rods positioned at various locations throughout the reactor core, wherein melting of a secondary internal cladding of the rod allows the fuel column therein to shift from the reactor core to place the reactor in a subcritical condition.

  13. Percolation thresholds for rod-like particles: polydispersity effects

    Science.gov (United States)

    Chatterjee, Avik P.

    2008-06-01

    A model based upon excluded volume considerations is presented for the connectedness percolation thresholds in polydisperse systems of cylindrical rod-like nanoparticles. The dependence of the percolation threshold upon polydispersity index and number-averaged aspect ratio is examined for two different distribution functions for the rod radii and lengths. The importance of accounting for polydispersity is explored in the context of measurements of the elastic moduli and electrical conductance in fibre-filled nanocomposites.

  14. Computer program for automatic generation of BWR control rod patterns

    Energy Technology Data Exchange (ETDEWEB)

    Taner, M.S.; Levine, S.H.; Hsia, M.Y. (Pennsylvania State Univ., University Park (United States))

    1990-01-01

    A computer program named OCTOPUS has been developed to automatically determine a control rod pattern that approximates some desired target power distribution as closely as possible without violating any thermal safety or reactor criticality constraints. The program OCTOPUS performs a semi-optimization task based on the method of approximation programming (MAP) to develop control rod patterns. The SIMULATE-E code is used to determine the nucleonic characteristics of the reactor core state.

  15. An Examination Of Fracture Splitting Parameters Of Crackable Connecting Rods

    Directory of Open Access Journals (Sweden)

    Zafer Özdemir

    2000-06-01

    Full Text Available Fracture splitting method is an innovative processing technique in the field of automobile engine connecting rod (con/rod manufacturing. Compared with traditional method, this technique has remarkable advantages. Manufacturing procedures, equipment and tools investment can be decreased and energy consumption reduced remarkably. Furthermore, product quality and bearing capability can also be improved. It provides a high quality, high accuracy and low cost route for producing connecting rods (con/rods. With the many advantages mentioned above, this method has attracted manufacturers attention and has been utilized in many types of con/rod manufacturing. In this article, the method and the advantages it provides, such as materials, notches for fracture splitting, fracture splitting conditions and fracture splitting equipment are discussed in detail. The paper describes an analysis of examination of fracture splitting parameters and optik-SEM fractography of C70S6 crackable connectıng rod. Force and velocity parameters are investigated. That uniform impact force distrubition starting from the starting notch causes brittle and cleavage failure mode is obtained as a result. This induces to decrease the toughness.

  16. Thermal hydraulics of rod bundles: The effect of eccentricity

    Energy Technology Data Exchange (ETDEWEB)

    Chauhan, Amit K., E-mail: amit_fmlab@yahoo.co.in [Fluid Mechanics Laboratory, Department of Applied Mechanics, Indian Institute of Technology Madras, Chennai 600036 (India); Prasad, B.V.S.S.S., E-mail: prasad@iitm.ac.in [Thermal Turbomachines Laboratory, Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai 600036 (India); Patnaik, B.S.V., E-mail: bsvp@iitm.ac.in [Fluid Mechanics Laboratory, Department of Applied Mechanics, Indian Institute of Technology Madras, Chennai 600036 (India)

    2013-10-15

    Highlights: • Present CFD investigation explores, whole bundle eccentricity for the first time. • Fluid flow and thermal characteristics in various subchannels are analyzed. • Mass flux distribution is particularly analyzed to study eccentricity effect. • Higher eccentricity resulted in a shoot up in rod surface temperature distribution. • Both tangential and radial flow in rod bundles has resulted due to eccentricity. -- Abstract: The effect of eccentricity on the fluid flow and heat transfer through a 19-rod bundle is numerically carried out. When the whole bundle shifts downwards with respect to the outer (pressure) tube, flow redistribution happens. This in turn is responsible for changes in mass flux, pressure and differential flow development in various subchannels. The heat flux imposed on the surface of the fuel rods and the mass flux through the subchannels determines the coolant outlet temperatures. The simulations are performed for a coolant flow Reynolds number of 4 × 10{sup 5}. For an eccentricity value of 0.7, the mass flux in the bottom most subchannel (l) was found to decrease by 10%, while the surface temperature of the fuel rod in the vicinity of this subchannel increased by 250% at the outlet section. Parameters of engineering interest including skin friction coefficient, Nusselt number, etc., have been systematically explored to study the effect of eccentricity on the rod bundle.

  17. Commissioning of a passive rod scanner at INB

    Energy Technology Data Exchange (ETDEWEB)

    Junqueira, Fabio da Silva; Oliveira, Carlos A.; Palheiros, Franklin, E-mail: carlossilva@inb.gov.br, E-mail: franklin@inb.gov.br [Industrias Nucleares do Brasil (INB), Resende, RJ (Brazil). Superintendencia de Engenharia do Combustivel; Fernandez, Pablo Jesus Piñer, E-mail: pineiro@tecnatom.es [Tecnatom, San Sebastian de los Reyes, Madrid (Spain)

    2015-07-01

    For the 21st reload for Angra 1, a shift from Standard to Advanced fuel design will be introduced, where the fuel assemblies under the new design will contain fuel rods with axial blanket, in line with ELETRONUCLEAR's requirement for a higher energy efficient reactor fuel. Additionally, fuel rods for Angra 2 and 3, using gadolinium type burnable poison, have to be submitted to inspections due to the demand for the same type of inspection, which cannot be certified at INB currently. In keeping with CNEN regulations, every fuel-assembly component must be inspected and certified by a qualified method. Nevertheless, INB lacks the means to perform the certification-required inspection aimed at determining the uranium enrichment and presence of gadolinium pellets inside the closed rods. Hence, the use is necessary of a scanner capable of inspecting differently enriched fuel rods and/or gadolinium pellets (axial blanket). This work aims to present the recent Passive Rod Scanner installed at INB with most advance technology in the area, making possible to completely fulfill Angra 1, 2 and 3 rods inspection at INB Resende site. (author)

  18. Swimming in a suspension of rod-like molecules

    Science.gov (United States)

    Shi, Juan; Powers, Thomas

    2016-11-01

    In nature, it is common for microorganisms to swim in fluids with microstructure, such as mucus. Motivated by this fact, there have been many recent theoretical, computational, and experimental studies of idealized swimmers in a dilute solution of flexible polymers. Here we study this problem from a different point of view by considering swimmers in a dilute solution of rigid rod-like polymers. We study the prescribed swimming problem of Taylor's sheet in a dilute suspension of non-Brownian rods. Using a simple continuum constitutive law for the suspension that describes the stress in terms of velocity gradient and local rod orientation, we calculate swimming speed to second order in the amplitude of the wave. Due to stresses induced by the presence of the rods, the first-order flow field differs from that of the Newtonian case. We find that the swimming speed increases linearly with rod concentration: the presence of the rods always makes the swimmer go faster. We also consider the problem of a finite swimmer by studying a two-dimensional circular squirmer. The squirmer is defined as a circle with a prescribed tangential slip velocity that leads to propulsion. By varying the prescribed slip boundary condition, we study both pushers and pullers.

  19. KE-Rod Initial Velocity of Hollow Cylindrical Charge

    Directory of Open Access Journals (Sweden)

    Wang Shushan

    2011-01-01

    Full Text Available KE-rod warhead is a kind of forward interception warhead. To control the KE-rods to disperse uniformly, the hollow cylindrical charge is applied. Initial velocity is crucial to KE-rods distribution and the coordination between the fuze and the warhead. Therefore, based on the classical Gurney formula of cylindrical charge and tabulate interlayer charge, a mathematical model for calculating the KE-rod initial velocity of hollow cylindrical charge has been deduced based on certain assumptions, of which the basis theory is energy and momentum conservation. To validate this deduced equation, high-speed photography and metal-pass target experimental methods were applied simultaneously to test the initial velocity of designed KE-rod warhead. Testing results clearly indicate that the calculated results of the derived mathematical model coincides with the experimental  results, and with the increase in hollow radius, the calculated results become much closer to the experimental results. But the calculated results of classical Gurney formula are far above the experimental results, and the relative error increases with increase in the hollow diameter. The derived mathematical model with satisfactory accuracy is applicable to calculate the KE-rod initial velocity of hollow cylindrical charge in engineering applications.Defence Science Journal, 2011, 61(1, pp.25-29, DOI:http://dx.doi.org/10.14429/dsj.61.72

  20. Finite Element Analysis and Design Optimization of Connecting Rod

    Directory of Open Access Journals (Sweden)

    Ashwini Mane

    2016-07-01

    Full Text Available The objective of this study is to improve the design of connecting rod of single cylinder four stroke Otto cycle engine by shape optimization. The main objective of this study is weight reduction of connecting rod and improving its performance without affecting its functionality. Finite element analysis is one of the most important tools of CAD/CAM CAE. For this study ANSYS analysis software is used for modeling, analysis and shape design optimization. Initially, according to design considerations maximum loads were calculated for various maximum operating loading conditions. Calculated loads used as a loading condition in various load steps of FEM analysis. Stresses generated across all the locations of connecting rod evaluated using ANSYS Workbench. For optimization ANSYS Shape optimization module is used and extracted the required shape of connecting rod. Final CAD model of optimized connecting rod is prepared in Design Modeler. Static structural analysis of modified design is performed and the results compared with baseline design. After result are validated with the help of Modified Goodman’s Diagram. From the shape optimization we could able to achieve 14.73% weight reduction in existing connecting rod. Since the optimized design is having sufficient life, the design is much improved as compared to the existing design

  1. Diurnal control of rod function in the chicken.

    Science.gov (United States)

    Schaeffel, F; Rohrer, B; Lemmer, T; Zrenner, E

    1991-06-01

    We studied rod function in the chicken by recording corneal electroretinograms (ERGs). The following experiments were performed to demonstrate rod function during daytime: (1) determining the dark-adaptation function; (2) measuring the spectral sensitivity by a a-b-wave amplitude criterion in response to monochromatic flickering light of different frequencies ranging from 6.5-40.8 Hz (duty cycle 1:1); (3) analyzing the response vs. log stimulus intensity (V-log I) function in order to reveal a possible two phase process; and (4) determining the spectral sensitivity function either in a non-dark adapted state or after dark adaptation of the animals for 1 and 24 h. None of these experiments demonstrated clear evidence of rod function during daytime. On the other hand, we found rods histologically by light- and electron microscopy. Therefore, we repeated our ERG recordings during the night (between midnight and 3:00 A.M.). Without previous dark adaptation, rod function could be seen immediately in the same experiments described above. The result shows that, in the chicken, rods are turned on endogenously during the night but are scarcely functional during the day.

  2. Influence of miscut on crystal truncation rod scattering

    Energy Technology Data Exchange (ETDEWEB)

    Munkholm, A.; Brennan, S. [Stanford Univ., CA (United States). Synchrotron Radiat. Lab.

    1999-04-01

    X-rays can be used to measure the roughness of a surface by the study of crystal truncation rod scattering. It is shown that for a simple cubic lattice the presence of a miscut surface with a regular step array has no effect on the scattered intensity of a single rod and that a distribution of terrace widths on the surface is shown to have the same effect as adding roughness to the surface. For a perfect crystal without miscut, the scattered intensity is the sum of the intensity from all the rods with the same in-plane momentum transfer. For all real crystals, the scattered intensity is better described as that from a single rod. It is shown that data-collection strategies must correctly account for the sample miscut or there is a potential for improperly measuring the rod intensity. This can result in an asymmetry in the rod intensity above and below the Bragg peak, which can be misinterpreted as being due to a relaxation of the surface. The calculations presented here are compared with data for silicon (001) wafers with 0.1 and 4 miscuts. (orig.) 22 refs.

  3. AN INTRODUCTION TO THE CUISENAIRE RODS, AN APPROACH TO THE TEACHING OF ELEMENTARY MATHEMATICS.

    Science.gov (United States)

    HULL, WILLIAM P.

    CUISENAIRE RODS ARE COLORED, RECTANGULAR PIECES OF WOOD ONE UNIT WIDE AND ANY NUMBER OF UNITS LONG. THE COLOR OF THE ROD DEPENDS UPON ITS LENGTH. RODS CAN BE USED IN KINDERGARTEN THROUGH HIGH SCHOOL, BUT ARE PARTICULARILY HELPFUL IN THE EARLY GRADES. THE RODS CAN BE USED TO TEACH CHILDREN SUCH CONCEPTS AS…

  4. Heterologous expression of hydrophobins RodA and RodB from Aspergillus fumigatus in host Pichia pastoris

    DEFF Research Database (Denmark)

    Pedersen, Mona Højgaard; Borodina, Irina; Frisvad, Jens Christian

    and investigation using the expression host Pichia pastoris. Methods and materials: The genes encoding hydrophobins RodA and RodB were amplified by RT-PCR with gene-specific primers from the total RNA isolated from the spores of A. fumigatus (AF296 strain). The resulting cDNA was cloned into TOPO vectors using TOPO...... proteins with the signal sequence of alfa-mating factor from Saccharomyces cerevisia known to work well for protein secretion from P. pastoris and the pPICZB plasmids had proteins cloned with their native signal sequences. The plasmids were linearized, transformed into P. pastoris strain X33...... of the purification of hydrophobins and functional investigations are being carried out at the moment. Conclusion: Hydrophobins RodA and RodB from Aspergillus fumigatus were successfully expressed and secreted by yeast host Pichia pastoris....

  5. Rod internal pressure quantification and distribution analysis using Frapcon

    Energy Technology Data Exchange (ETDEWEB)

    Jessee, Matthew Anderson [ORNL; Wieselquist, William A [ORNL; Ivanov, Kostadin [Pennsylvania State University, University Park

    2015-09-01

    This report documents work performed supporting the Department of Energy (DOE) Office of Nuclear Energy (NE) Fuel Cycle Technologies Used Fuel Disposition Campaign (UFDC) under work breakdown structure element 1.02.08.10, ST Analysis. In particular, this report fulfills the M4 milestone M4FT- 15OR0810036, Quantify effects of power uncertainty on fuel assembly characteristics, within work package FT-15OR081003 ST Analysis-ORNL. This research was also supported by the Consortium for Advanced Simulation of Light Water Reactors (http://www.casl.gov), an Energy Innovation Hub (http://www.energy.gov/hubs) for Modeling and Simulation of Nuclear Reactors under U.S. Department of Energy Contract No. DE-AC05-00OR22725. The discharge rod internal pressure (RIP) and cladding hoop stress (CHS) distributions are quantified for Watts Bar Nuclear Unit 1 (WBN1) fuel rods by modeling core cycle design data, operation data (including modeling significant trips and downpowers), and as-built fuel enrichments and densities of each fuel rod in FRAPCON-3.5. A methodology is developed which tracks inter-cycle assembly movements and assembly batch fabrication information to build individual FRAPCON inputs for each evaluated WBN1 fuel rod. An alternate model for the amount of helium released from the zirconium diboride (ZrB2) integral fuel burnable absorber (IFBA) layer is derived and applied to FRAPCON output data to quantify the RIP and CHS for these types of fuel rods. SCALE/Polaris is used to quantify fuel rodspecific spectral quantities and the amount of gaseous fission products produced in the fuel for use in FRAPCON inputs. Fuel rods with ZrB2 IFBA layers (i.e., IFBA rods) are determined to have RIP predictions that are elevated when compared to fuel rod without IFBA layers (i.e., standard rods) despite the fact that IFBA rods often have reduced fill pressures and annular fuel pellets. The primary contributor to elevated RIP predictions at burnups less than and greater than 30 GWd

  6. Use of Supplemental Short Pre-Contoured Accessory Rods and Cobalt Chrome Alloy Posterior Rods Reduces Primary Rod Strain and Range of Motion Across the Pedicle Subtraction Osteotomy Level

    DEFF Research Database (Denmark)

    Hallager, Dennis Winge; Gehrchen, Poul Martin; Dahl, Benny

    2016-01-01

    STUDY DESIGN: In vitro cadaveric biomechanical study. OBJECTIVE: To assess effects of 4-rod reconstruction, rod material, and anterior column support on motion and surface rod strain in a pedicle subtraction osteotomy model. SUMMARY OF BACKGROUND DATA: Pedicle subtraction osteotomy (PSO) can corr...

  7. Construction, Calibration, and Validation of a Simple Patch-Clamp Amplifier for Physiology Education

    Science.gov (United States)

    Rouzrokh, Ali; Ebrahimi, Soltan Ahmed; Mahmoudian, Massoud

    2009-01-01

    A modular patch-clamp amplifier was constructed based on the Strickholm design, which was initially published in 1995. Various parts of the amplifier such as the power supply, input circuit, headstage, feedback circuit, output and nulling circuits were redesigned to use recent software advances and fabricated using the common lithographic printed…

  8. Efficiency of frequency conversion of high power laser and KDP crystal clamping method

    Science.gov (United States)

    Yan, Han; Du, Weifeng; Pei, Guoqing; Qin, Tinghai; Ye, Lang; Xu, Xu

    2017-05-01

    In the high power solid laser driver, the frequency conversion unit is of strict requirement to meet the drive condition of ICF. The performance of large caliber KDP crystal, which is the core of frequency conversion of laser, is a vital aspect affecting the overall technical index of the laser driver. In order to get a higher efficiency of frequency conversion, KDP crystal must keep a better surface condition, which asks for high-quality assemblage and adjustment. The current method used in engineering has insufficient knowledge and recognition on surface deformation control of the crystal. Meanwhile, the method itself is of low efficiency on clamping, and lacks of protection for the crystal. Thus, in this article an investigation of crystal clamping method with lower force was performed, factors affecting the surface of crystal were explored, through both imitation and experiment. The clamping method was redesigned and the frequency conversion efficiency was tested. Meanwhile, with the new method, clamping efficiency increases, the optical performance of crystals improves, and the crystals get better protection.

  9. Five-Level Active-Neutral-Point-Clamped DC/DC Converter

    DEFF Research Database (Denmark)

    Liu, Dong; Deng, Fujin; Chen, Zhe

    Multi-level converters are getting more and more attentions because of their obvious merits such as lower voltage stress and harmonic, smaller size of output filters, and so on. In this paper, a five-level active-neutral-point-clamped (5L-ANPC) dc/dc converter is proposed for power transfer...

  10. Two-Dimensional Fiber Positioning and Clamping Device for Product-Internal Microassembly

    NARCIS (Netherlands)

    Henneken, V.A.; Sassen, W.P.; Van der Vlist, W.; Wien, W.H.A.; Tichem, M.; Sarro, P.M.

    2008-01-01

    In this paper, we present a microelectromechanical systems-based two-degrees-of-freedom positioning device combined with a clamping structure for positioning and constraining an optical fiber. The fiber position can be controlled in the two directions perpendicular to the fiber axis using two specif

  11. A bulldog clamp that was forgotten during a coronary artery bypass operation 8 years ago

    Science.gov (United States)

    Celkan, Mehmet Adnan; Bayatli, Kivanc

    2012-01-01

    Prevention of retained foreign bodies in the pericardial cavity is critical for patient safety. We report a patient with a bulldog clamp that was forgotten during a coronary artery bypass operation 8 years ago, which was detected by chance and removed. PMID:22815324

  12. A Single-Strand Annealing Protein Clamps DNA to Detect and Secure Homology.

    Directory of Open Access Journals (Sweden)

    Marcel Ander

    2015-08-01

    Full Text Available Repair of DNA breaks by single-strand annealing (SSA is a major mechanism for the maintenance of genomic integrity. SSA is promoted by proteins (single-strand-annealing proteins [SSAPs], such as eukaryotic RAD52 and λ phage Redβ. These proteins use a short single-stranded region to find sequence identity and initiate homologous recombination. However, it is unclear how SSAPs detect homology and catalyze annealing. Using single-molecule experiments, we provide evidence that homology is recognized by Redβ monomers that weakly hold single DNA strands together. Once annealing begins, dimerization of Redβ clamps the double-stranded region and nucleates nucleoprotein filament growth. In this manner, DNA clamping ensures and secures a successful detection for DNA sequence homology. The clamp is characterized by a structural change of Redβ and a remarkable stability against force up to 200 pN. Our findings not only present a detailed explanation for SSAP action but also identify the DNA clamp as a very stable, noncovalent, DNA-protein interaction.

  13. Critical clamp loader processing by an essential AAA+ protease in Caulobacter crescentus.

    Science.gov (United States)

    Vass, Robert H; Chien, Peter

    2013-11-01

    Chromosome replication relies on sliding clamps that are loaded by energy-dependent complexes. In Escherichia coli, the ATP-binding clamp loader subunit DnaX exists as both long (τ) and short (γ) forms generated through programmed translational frameshifting, but the need for both forms is unclear. Here, we show that in Caulobacter crescentus, DnaX isoforms are unexpectedly generated through partial proteolysis by the AAA+ protease casein lytic proteinase (Clp) XP. We find that the normally processive ClpXP protease partially degrades DnaX to produce stable fragments upon encountering a glycine-rich region adjacent to a structured domain. Increasing the sequence complexity of this region prevents partial proteolysis and generates a τ-only form of DnaX in vivo that is unable to support viability on its own. Growth is restored when γ is provided in trans, but these strains are more sensitive to DNA damage compared with strains that can generate γ through proteolysis. Our work reveals an unexpected mode of partial processing by the ClpXP protease to generate DnaX isoforms, demonstrates that both τ and γ forms of DnaX are required for Caulobacter viability, and identifies a role for clamp loader diversity in responding to DNA damage. The conservation of distinct DnaX isoforms throughout bacteria despite fundamentally different mechanisms for producing them suggests there may be a conserved need for alternate clamp loader complexes during DNA damaging conditions.

  14. Characterization of a patch-clamp microchannel array towards neuronal networks analysis

    DEFF Research Database (Denmark)

    Alberti, Massimo; Snakenborg, Detlef; Lopacinska, Joanna M.

    2010-01-01

    for simultaneous patch clamping of cultured cells or neurons in the same network. A disposable silicon/silicon dioxide (Si/SiO2) chip with a microhole array was integrated in a microfluidic system for cell handling, perfusion and electrical recording. Fluidic characterization showed that our PC mu CA can work...

  15. The Response Clamp: Functional characterization of neural systems using closed-loop control

    Directory of Open Access Journals (Sweden)

    Avner eWallach

    2013-01-01

    Full Text Available The voltage clamp method, pioneered by Hodgkin, Huxley and Katz, laid the foundations to neurophysiological research. Its core rationale is the use of closed-loop control as a tool for system characterization. A recently introduced method, the response clamp, extends the voltage clamp rationale to the functional, phenomenological level. The method consists of on-line estimation of a response variable of interest (e.g. the probability of response or its latency and a simple feedback control mechanism designed to tightly converge this variable towards a desired trajectory. In the present contribution I offer a perspective on this novel method and its applications in the broader context of system identification and characterization. First, I demonstrate how internal state variables are exposed using the method, and how the use of several controllers may allow for a detailed, multi-variable characterization of the system. Second, I discuss three different categories of applications of the method: (i exploration of intrinsically generated dynamics, (ii exploration of extrinsically generated dynamics and (iii generation of input-output trajectories. The relation of these categories to similar uses in the voltage clamp and other techniques is also discussed. Finally, I discuss the method’s limitations, as well as its possible synthesis with existing complementary approaches.

  16. Early vs delayed clamping of the umbilical cord in full term, preterm and very preterm infants

    DEFF Research Database (Denmark)

    Moller, N.K.; Weber, T.

    2008-01-01

    Randomized studies from 2006 and two meta-analyses published in 2007 agree that clamping of the umbilical cord can be delayed. For the preterm and very preterm infant benefits include less need for blood transfusion and less morbidity, especially for the very preterm male infant. For the term...

  17. Enhanced Buck-Boost Three-Level Neutral-Point-Clamped Inverters

    DEFF Research Database (Denmark)

    Tan, K. K.; Gao, F.; Chiang Loh, Poh

    2009-01-01

    In traditional three-level neutral-point-clamped (NPC) inverters, a major issue is capacitor voltage imbalance, which results in low order harmonics. The compensation of the capacitor voltages often require additional control complexity, which cannot be conveniently implemented. The "alternative ...

  18. Thermal and Efficiency Analysis of Five-Level Multilevel-Clamped Multilevel Converter Considering Grid Codes

    DEFF Research Database (Denmark)

    Ma, Ke; Muñoz-Aguilar, R. S.; Rodriguez, Pedro;

    2014-01-01

    In this paper, a five-level multilevel-clamped multilevel converter (5L- MLC2) topology is analyzed based on a typical grid integration application for renewable energy system. The loss and thermal distributions of the power devices in different switching legs are investigated and illustrated und...

  19. Pulse and Trapezoidal Voltage Clamp Applied To Jurkat Cells: A T- Lymphocyte Cell Line

    Science.gov (United States)

    1993-04-01

    clamp. (Upward deflection represents depolarization). Low frequency oscillations are clearly visible. Such oscillations have been described by Maltsev ...1952. (8) Maltsev , V. A. Oscillating and triggering properties of T cell membrane potential. Imun. Lett. 26:277-282, 1990. 13 (9) Gallin, E. K

  20. Two-Dimensional Fiber Positioning and Clamping Device for Product-Internal Microassembly

    NARCIS (Netherlands)

    Henneken, V.A.; Sassen, W.P.; Van der Vlist, W.; Wien, W.H.A.; Tichem, M.; Sarro, P.M.

    2008-01-01

    In this paper, we present a microelectromechanical systems-based two-degrees-of-freedom positioning device combined with a clamping structure for positioning and constraining an optical fiber. The fiber position can be controlled in the two directions perpendicular to the fiber axis using two specif

  1. Pulse-Width-Modulation of Neutral-Point-Clamped Sparse Matrix Converter

    DEFF Research Database (Denmark)

    Loh, P.C.; Blaabjerg, Frede; Gao, F.

    2007-01-01

    literature. Addressing the afore-described issues, this paper focuses on the operational mode analysis of a three-level sparse matrix converter implemented using a neutral-point-clamped inversion stage, and  the design of a number of PWM and modulation ratio compensation schemes for controlling the converter...

  2. Trans-Z-source and Γ-Z-source neutral-point-clamped inverters

    DEFF Research Database (Denmark)

    Wei, Mo; Loh, Poh Chiang; Blaabjerg, Frede

    2015-01-01

    Z-source neutral-point-clamped (NPC) inverters are earlier proposed for obtaining voltage buck-boost and three-level switching simultaneously. Their performances are, however, constrained by a trade-off between their input-to-output gain and modulation ratio. This trade-off can lead to high...

  3. Delayed cord clamping and haemoglobin levels in infancy : a randomised controlled trial in term babies

    NARCIS (Netherlands)

    van Rheenen, Patrick; de Moor, Lette; Eschbach, Sanne; de Grooth, Hannah; Brabin, Bernard

    Objectives This study was carried out to assess whether delaying umbilical cord clamping is effective in improving the haematological status of term infants living in a malaria-endemic area, and whether this is associated with complications in infants and mothers. Metyhods We randomly assigned women

  4. Delayed umbilical cord clamping for reducing anaemia in low birthweight infants : implications for developing countries

    NARCIS (Netherlands)

    van Rheenen, Patrick F.; Gruschke, Sebastian; Brabin, Bernard J.

    BACKGROUND: Cheap and effective interventions are needed to reduce the risk of infant anaemia in developing countries. Delayed cord clamping (DCC) has been shown to be a simple, safe and cost-free delivery procedure that augments red cell mass in appropriate-for-gestational-age term and preterm

  5. Delayed cord clamping in South African neonates with expected low birthweight : a randomised controlled trial

    NARCIS (Netherlands)

    Tiemersma, Sybrich; Heistein, Julia; Ruijne, Roos; Lopez, Gustavo; van Lobenstein, Jeroen; van Rheenen, Patrick

    OBJECTIVE: To evaluate safety and haematological effects of delayed cord clamping (DCC) in infants with expected low birthweight born in a resource-poor setting. METHODS: Randomised controlled trial involving pregnant women in early labour ≥18 years with intrapartum symphysal-fundal height ≤32 cm.

  6. Early umbilical cord clamping contributes to elevated blood lead levels among infants with higher lead exposure.

    Science.gov (United States)

    Chaparro, Camila M; Fornes, Raymond; Neufeld, Lynnette M; Tena Alavez, Gilberto; Eguía-Líz Cedillo, Raúl; Dewey, Kathryn G

    2007-11-01

    To investigate whether infant iron status, modified by umbilical cord clamping time and infant feeding mode, affected infant blood lead concentration at 6 months of age. Participants were a subset of women and their infants randomized to receive early (10 seconds) or delayed (2 minutes) umbilical cord clamping and were monitored to 6 months postpartum in Mexico City. Iron and lead status was analyzed in maternal, placental, and 6-month infant blood samples. Baseline maternal lead exposure data and infant feeding data at 2, 4, and 6 months were collected. In the total sample, maternal blood lead concentration, infant ferritin, and breast-feeding practices predicted infant blood lead concentration. Among infants with higher placental blood lead concentration and breast-fed infants not receiving any iron-fortified formula or milk at 6 months, early clamping increased infant blood lead concentration, an effect mediated in part via decreased infant iron status. Early cord clamping, by decreasing infant iron status, contributes to higher blood lead concentrations at 6 months of age among infants at high risk.

  7. A New Preparation of Pancreatic Ducts for Patch-Clamp Studies

    DEFF Research Database (Denmark)

    Novak, Ivana; Hug, M.J.

    1995-01-01

    parameters, monitored with the whole-cell patch-clamp method, and those in isolated perfused ducts, monitored with the conventional microelectrodes [Novak I, Greger R: Pflügers Arch 1988;411:58-68, 546-553], are comparable. Similar conclusion can be made about the calcium measurements [Hug M, et al: Pflügers...

  8. A direct proofreader-clamp interaction stabilizes the Pol III replicase in the polymerization mode

    NARCIS (Netherlands)

    Jergic, Slobodan; Horan, Nicholas P.; Elshenawy, Mohamed M.; Mason, Claire E.; Urathamakul, Thitima; Ozawa, Kiyoshi; Robinson, Andrew; Goudsmits, Joris M. H.; Wang, Yao; Pan, Xuefeng; Beck, Jennifer L.; van Oijen, Antoine M.; Huber, Thomas; Hamdan, Samir M.; Dixon, Nicholas E.

    2013-01-01

    Processive DNA synthesis by the alpha epsilon theta core of the Escherichia coli Pol III replicase requires it to be bound to the beta(2) clamp via a site in the a polymerase subunit. How the epsilon proofreading exonuclease subunit influences DNA synthesis by alpha was not previously understood. In

  9. Glucose consumption by various tissues in pregnant rats : effects of a 6-day euglycaemic hyperinsulinaemic clamp

    NARCIS (Netherlands)

    Nieuwenhuizen, AG; Schuiling, GA; Bonen, A; Paans, AMJ; Vaalburg, W; Koiter, TR

    1998-01-01

    In the course of pregnancy maternal tissues become increasingly more insensitive to insulin. As 6 days of euglycaemic hyperinsulinaemic clamping, from day 8 until 14 of gestation, ameliorates total glucose consumption, we analysed the contribution of individual tissues in this phenomenon. We measure

  10. Experimental and numerical analysis of clamped joints in front motorbike suspensions

    Directory of Open Access Journals (Sweden)

    Vincenzi N.

    2010-06-01

    Full Text Available Clamped joints are shaft-hub connections used, as an instance, in front motorbike suspensions to lock the steering plates with the legs and the legs with the wheel pin, by means of one or two bolts. The preloading force, produced during the tightening process, should be evaluated accurately, since it must lock safely the shaft, without overcoming the yielding point of the hub. Firstly, friction coefficients have been evaluated on “ad-hoc designed” specimens, by applying the Design of Experiment approach: the applied tightening torque has been precisely related to the imposed preloading force. Then, the tensile state of clamps have been evaluated both via FEM and by leveraging some design formulae proposed by the Authors as function of the preloading force and of the clamp geometry. Finally, the results have been compared to those given by some strain gauges applied on the tested clamps: the discrepancies between numerical analyses, the design formulae and the experimental results remains under a threshold of 10%.

  11. A bulldog clamp that was forgotten during a coronary artery bypass operation 8 years ago.

    Science.gov (United States)

    Celkan, Mehmet Adnan; Bayatli, Kivanc

    2012-10-01

    Prevention of retained foreign bodies in the pericardial cavity is critical for patient safety. We report a patient with a bulldog clamp that was forgotten during a coronary artery bypass operation 8 years ago, which was detected by chance and removed.

  12. Calcium Release in Frog Cut Twitch Fibers Exposed to Different Ionic Environments under Voltage Clamp

    National Research Council Canada - National Science Library

    Hui, Chiu Shuen

    1999-01-01

    Calcium release was measured in highly stretched frog cut twitch fibers mounted in a double Vaseline-gap voltage clamp chamber, with the internal solution containing 20 mM EGTA plus 0.4 or 1.8 mM added calcium...

  13. Characterization of control rod worths and fuel rod power peaking factors in the university of Utah TRIGA Mark I reactor

    Directory of Open Access Journals (Sweden)

    Alroumi Fawaz

    2016-01-01

    Full Text Available Control rod reactivity (worths for the three control rods and fuel rod power peaking factors in the University of Utah research reactor (100 kW TRIGA Mark I are characterized using the AGENT code system and the results described in this paper. These values are compared to the MCNP6 and existing experimental measurements. In addition, the eigenvalue, neutron spatial flux distributions and reaction rates are analyzed and discussed. The AGENT code system is widely benchmarked for various reactor types and complexities in their geometric arrangements of the assemblies and reactor core material distributions. Thus, it is used as a base methodology to evaluate neutronics variables of the research reactor at the University of Utah. With its much shorter computation time than MCNP6, AGENT provides agreement with the MCNP6 within a 0.5 % difference for the eigenvalue and a maximum difference of 10% in the power peaking factor values. Differential and integral control rod worths obtained by AGENT show well agreement with MCNP6 and the theoretical model. However, regulating the control rod worth is somewhat overestimated by both MCNP6 and AGENT models when compared to the experimental/theoretical values. In comparison to MCNP6, the total control rod worths and shutdown margin obtained with AGENT show better agreement to the experimental values.

  14. MATLAB implementation of a dynamic clamp with bandwidth >125 KHz capable of generating INa at 37°C

    Science.gov (United States)

    Clausen, Chris; Valiunas, Virginijus; Brink, Peter R.; Cohen, Ira S.

    2012-01-01

    We describe the construction of a dynamic clamp with bandwidth >125 KHz that utilizes a high performance, yet low cost, standard home/office PC interfaced with a high-speed (16 bit) data acquisition module. High bandwidth is achieved by exploiting recently available software advances (code-generation technology, optimized real-time kernel). Dynamic-clamp programs are constructed using Simulink, a visual programming language. Blocks for computation of membrane currents are written in the high-level matlab language; no programming in C is required. The instrument can be used in single- or dual-cell configurations, with the capability to modify programs while experiments are in progress. We describe an algorithm for computing the fast transient Na+ current (INa) in real time, and test its accuracy and stability using rate constants appropriate for 37°C. We then construct a program capable of supplying three currents to a cell preparation: INa, the hyperpolarizing-activated inward pacemaker current (If), and an inward-rectifier K+ current (IK1). The program corrects for the IR drop due to electrode current flow, and also records all voltages and currents. We tested this program on dual patch-clamped HEK293 cells where the dynamic clamp controls a current-clamp amplifier and a voltage-clamp amplifier controls membrane potential, and current-clamped HEK293 cells where the dynamic clamp produces spontaneous pacing behavior exhibiting Na+ spikes in otherwise passive cells. PMID:23224681

  15. Evaluation of diel patterns of relative changes in cell turgor of tomato plants using leaf patch clamp pressure probes

    NARCIS (Netherlands)

    Lee, K.M.; Driever, S.M.; Heuvelink, E.; Rüger, S.; Zimmermann, U.; Gelder, de A.; Marcelis, L.F.M.

    2012-01-01

    Relative changes in cell turgor of leaves of well-watered tomato plants were evaluated using the leaf patch clamp pressure probe (LPCP) under dynamic greenhouse climate conditions. Leaf patch clamp pressure changes, a measure for relative changes in cell turgor, were monitored at three different hei

  16. An AFM-based stiffness clamp for dynamic control of rigidity.

    Directory of Open Access Journals (Sweden)

    Kevin D Webster

    Full Text Available Atomic force microscopy (AFM has become a powerful tool for measuring material properties in biology and imposing mechanical boundary conditions on samples from single molecules to cells and tissues. Constant force or constant height can be maintained in an AFM experiment through feedback control of cantilever deflection, known respectively as a 'force clamp' or 'position clamp'. However, stiffness, the third variable in the Hookean relation F = kx that describes AFM cantilever deflection, has not been dynamically controllable in the same way. Here we present and demonstrate a 'stiffness clamp' that can vary the apparent stiffness of an AFM cantilever. This method, employable on any AFM system by modifying feedback control of the cantilever, allows rapid and reversible tuning of the stiffness exposed to the sample in a way that can decouple the role of stiffness from force and deformation. We demonstrated the AFM stiffness clamp on two different samples: a contracting fibroblast cell and an expanding polyacrylamide hydrogel. We found that the fibroblast, a cell type that secretes and organizes the extracellular matrix, exhibited a rapid, sub-second change in traction rate (dF/dt and contraction velocity (dx/dt in response to step changes in stiffness between 1-100 nN/µm. This response was independent of the absolute contractile force and cell height, demonstrating that cells can react directly to changes in stiffness alone. In contrast, the hydrogel used in our experiment maintained a constant expansion velocity (dx/dt over this range of stiffness, while the traction rate (dF/dt changed with stiffness, showing that passive materials can also behave differently in different stiffness environments. The AFM stiffness clamp presented here, which is applicable to mechanical measurements on both biological and non-biological samples, may be used to investigate cellular mechanotransduction under a wide range of controlled mechanical boundary

  17. Influence of phenylephrine or ephedrine on maternal hemodynamics upon umbilical cord clamping during cesarean delivery.

    Science.gov (United States)

    Quan, Zhefeng; Tian, Ming; Chi, Ping; Cao, Yinghao; Li, Xin; Peng, Kejun

    2013-11-01

    Vasopressors ephedrine and phenylephrine are commonly used with spinal anesthesia during cesarean delivery. Studies on them have focused on the period before the umbilical cord is clamped, although anesthesia is continuously administered throughout and after this event. This study aimed to compare the effects of these drugs on maternal hemodynamics at and after clamping of the umbilical cord. Prospective, randomized, double-blind study. Parturients (n = 60) scheduled for elective cesarean delivery were randomly divided into an ephedrine group and a phenylephrine group. Each woman received an intrathecal injection of bupivacaine (7.5 mg). Patients in the ephedrine and phenylephrine groups were infused continuously with ephedrine (0.02 mg×kg-1×min-1) or phenylephrine (0.25 μg×kg-1×min-1), respectively, from immediately after the injection of bupivacaine until termination 10 minutes after the umbilical cord was clamped (the endpoint). Hemodynamic changes were recorded. After clamping the umbilical cord, the patients who were administered ephedrine experienced significant increases in heart rate (89 ± 11 beats/min to 106 ± 15 beats/min), cardiac output (6.4 ± 0.9 l/min to 7.6 ± 1.2 l/min) and cardiac index (3.5 ± 0.39 l×min-1×m-2 to 4.3 ± 0.48 l×min-1×m-2), while the systemic vascular resistance decreased (908 ± 296 dyne·s/cm5 to 711 ± 285 dyne·s/cm5). Such differences were not observed in the patients who received phenylephrine. Moreover, the heart rate of patients administered ephedrine was higher than that of patients given phenylephrine after clamping the umbilical cord. Continuous infusion of phenylephrine during cesarean delivery maintains a stable maternal hemodynamic status better than ephedrine.

  18. A physiological approach to the timing of umbilical cord clamping at birth.

    Science.gov (United States)

    Hooper, Stuart B; Polglase, Graeme R; te Pas, Arjan B

    2015-07-01

    Umbilical cord clamping at birth has a major impact on an infant's cardiovascular system that varies in significance depending upon whether the infant has commenced breathing. As umbilical venous return is a major source of preload for the left ventricle during fetal life, recent experimental evidence has shown that clamping the umbilical cord severely limits cardiac venous return in the absence of pulmonary ventilation. As a result, cardiac output greatly reduces and remains low until breathing commences. Once the infant begins breathing, aeration of the lung triggers a large increase in pulmonary blood flow, which replaces umbilical venous return as the source of preload for the left ventricle. As a result, cardiac output markedly increases, as indicated by an increase in heart rate immediately after birth. Thus, infants born apnoeic and hypoxic and have their cords immediately clamped, are likely to have a restricted cardiac output combined with hypoxia. As increased cardiac output is a major physiological defence mechanism that counteracts the effects of hypoxaemia, limiting the increase in cardiac output exposes the infant to ischaemia along with hypoxia. However, if the infant commences breathing, aerates its lungs and increases pulmonary blood flow before the umbilical cord is clamped, then pulmonary venous return can immediately take over the supply of left ventricular preload upon cord clamping. As a result, there is no intervening period of reduced preload and cardiac output and the large swings in arterial pressures and flows are reduced leading to a more stable circulatory transition. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  19. Ventilation before Umbilical Cord Clamping Improves the Physiological Transition at Birth.

    Science.gov (United States)

    Bhatt, Sasmira; Polglase, Graeme R; Wallace, Euan M; Te Pas, Arjan B; Hooper, Stuart B

    2014-01-01

    The transition from a fetus to a neonate at birth represents a critical phase in our life. Most infants make this transition without complications, but preterm infants usually require some form of assistance due to immature cardiopulmonary systems that predispose them to lifelong sequelae. As the incidence of preterm birth is increasing, there is now an urgent need for the development of management strategies that facilitate this transition, which will likely include improved strategies for the management of the maternal third stage of labor. For instance, recent studies on the physiological transition at birth have led to the discovery that establishing ventilation in the infant before the umbilical cord is clamped greatly stabilizes the cardiovascular transition at birth. While most benefits of delayed clamping previously have been attributed to an increase in placenta to infant blood transfusion, clearly there are other significant benefits for the infant, which are not well understood. Nevertheless, if ventilation can be established before cord clamping in a preterm infant, the large adverse changes in cardiac function that normally accompanies umbilical cord clamping can be avoided. As preterm infants have an immature cerebral vascular bed, large swings in cardiovascular function places them at high risk of cerebral vascular rupture and the associated increased risk of mortality and morbidity. In view of the impact that cord clamping has on the cardiovascular transition at birth, it is also time to re-examine some of the strategies used in the management of the third stage of labor. These include the appropriate timing of uterotonic administration in relation to delivery of the infant and placenta. As there is a lack of evidence on the effects these individual practices have on the infant, there is a necessity to improve our understanding of their impact in order to develop strategies that facilitate the transition to newborn life.

  20. An AFM-based stiffness clamp for dynamic control of rigidity.

    Science.gov (United States)

    Webster, Kevin D; Crow, Ailey; Fletcher, Daniel A

    2011-03-08

    Atomic force microscopy (AFM) has become a powerful tool for measuring material properties in biology and imposing mechanical boundary conditions on samples from single molecules to cells and tissues. Constant force or constant height can be maintained in an AFM experiment through feedback control of cantilever deflection, known respectively as a 'force clamp' or 'position clamp'. However, stiffness, the third variable in the Hookean relation F = kx that describes AFM cantilever deflection, has not been dynamically controllable in the same way. Here we present and demonstrate a 'stiffness clamp' that can vary the apparent stiffness of an AFM cantilever. This method, employable on any AFM system by modifying feedback control of the cantilever, allows rapid and reversible tuning of the stiffness exposed to the sample in a way that can decouple the role of stiffness from force and deformation. We demonstrated the AFM stiffness clamp on two different samples: a contracting fibroblast cell and an expanding polyacrylamide hydrogel. We found that the fibroblast, a cell type that secretes and organizes the extracellular matrix, exhibited a rapid, sub-second change in traction rate (dF/dt) and contraction velocity (dx/dt) in response to step changes in stiffness between 1-100 nN/µm. This response was independent of the absolute contractile force and cell height, demonstrating that cells can react directly to changes in stiffness alone. In contrast, the hydrogel used in our experiment maintained a constant expansion velocity (dx/dt) over this range of stiffness, while the traction rate (dF/dt) changed with stiffness, showing that passive materials can also behave differently in different stiffness environments. The AFM stiffness clamp presented here, which is applicable to mechanical measurements on both biological and non-biological samples, may be used to investigate cellular mechanotransduction under a wide range of controlled mechanical boundary conditions.

  1. Ventilation before Umbilical Cord Clamping improves the physiological transition at birth.

    Directory of Open Access Journals (Sweden)

    Sasmira eBhatt

    2014-10-01

    Full Text Available The transition from a fetus to a neonate at birth represents a critical phase in our life. Most infants make this transition without complications, but preterm infants usually require some form of assistance due to immature cardiopulmonary systems that predispose them to lifelong sequelae. As the incidence of preterm birth is increasing, there is now an urgent need for the development of management strategies that facilitate this transition, which will likely include improved strategies for the management of the maternal third stage of labour. For instance, recent studies on the physiological transition at birth have led to the discovery that establishing ventilation in the infant before the umbilical cord is clamped greatly stabilizes the cardiovascular transition at birth. While most benefits of delayed clamping have previously been attributed to an increase in placenta to infant blood transfusion, clearly there are other significant benefits for the infant, which are not well understood. Nevertheless, if ventilation can be established before cord clamping in a preterm infant, the large adverse changes in cardiac function that normally accompanies umbilical cord clamping can be avoided. As preterm infants have an immature cerebral vascular bed, large swings in cardiovascular function places them at high risk of cerebral vascular rupture and the associated increased risk of mortality and morbidity. In view of the impact that cord clamping has on the cardiovascular transition at birth, it is also time to re-examine some of the strategies used in the management of the third stage of labour. These include the appropriate timing of uterotonic administration in relation to delivery of the infant and placenta. As there is a lack of evidence on the effects these individual practices have on the infant, there is a necessity to improve our understanding of their impact in order to develop strategies that facilitate the transition to newborn life.

  2. Detection of single photons by toad and mouse rods.

    Science.gov (United States)

    Reingruber, Jürgen; Pahlberg, Johan; Woodruff, Michael L; Sampath, Alapakkam P; Fain, Gordon L; Holcman, David

    2013-11-26

    Amphibian and mammalian rods can both detect single photons of light even though they differ greatly in physical dimensions, mammalian rods being much smaller in diameter than amphibian rods. To understand the changes in physiology and biochemistry required by such large differences in outer segment geometry, we developed a computational approach, taking into account the spatial organization of the outer segment divided into compartments, together with molecular dynamics simulations of the signaling cascade. We generated simulations of the single-photon response together with intrinsic background fluctuations in toad and mouse rods. Combining this computational approach with electrophysiological data from mouse rods, we determined key biochemical parameters. On average around one phosphodiesterase (PDE) molecule is spontaneously active per mouse compartment, similar to the value for toad, which is unexpected due to the much smaller diameter in mouse. A larger number of spontaneously active PDEs decreases dark noise, thereby improving detection of single photons; it also increases cGMP turnover, which accelerates the decay of the light response. These constraints explain the higher PDE density in mammalian compared with amphibian rods that compensates for the much smaller diameter of mammalian disks. We further find that the rate of cGMP hydrolysis by light-activated PDE is diffusion limited, which is not the case for spontaneously activated PDE. As a consequence, in the small outer segment of a mouse rod only a few activated PDEs are sufficient to generate a signal that overcomes noise, which permits a shorter lifetime of activated rhodopsin and greater temporal resolution.

  3. Control Rod Driveline Reactivity Feedback Model for Liquid Metal Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Young-Min; Jeong, Hae-Yong; Chang, Won-Pyo; Cho, Chung-Ho; Lee, Yong-Bum

    2008-01-15

    The thermal expansion of the control rod drivelines (CRDL) is one important passive mitigator under all unprotected accident conditions in the metal and oxide cores. When the CRDL are washed by hot sodium in the coolant outlet plenum, the CRDL thermally expands and causes the control rods to be inserted further down into the active core region, providing a negative reactivity feedback. Since the control rods are attached to the top of the vessel head and the core attaches to the bottom of the reactor vessel (RV), the expansion of the vessel wall as it heats will either lower the core or raise the control rods supports. This contrary thermal expansion of the reactor vessel wall pulls the control rods out of the core somewhat, providing a positive reactivity feedback. However this is not a safety factor early in a transient because its time constant is relatively large. The total elongated length is calculated by subtracting the vessel expansion from the CRDL expansion to determine the net control rod expansion into the core. The system-wide safety analysis code SSC-K includes the CRDL/RV reactivity feedback model in which control rod and vessel expansions are calculated using single-nod temperatures for the vessel and CRDL masses. The KALIMER design has the upper internal structures (UIS) in which the CRDLs are positioned outside the structure where they are exposed to the mixed sodium temperature exiting the core. A new method to determine the CRDL expansion is suggested. Two dimensional hot pool thermal hydraulic model (HP2D) originally developed for the analysis of the stratification phenomena in the hot pool is utilized for a detailed heat transfer between the CRDL mass and the hot pool coolant. However, the reactor vessel wall temperature is still calculated by a simple lumped model.

  4. Strategy for Fuel Rod Receipt, Characterization, Sample Allocation for the Demonstration Sister Rods

    Energy Technology Data Exchange (ETDEWEB)

    Marschman, Steven C. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Warmann, Stephan A. [Portage, Inc., Idaho Falls, ID (United States); Rusch, Chris [NAC International, Inc., Norcross, GA (United States)

    2014-03-01

    , inert gas backfilling, and transfer to an Independent Spent Fuel Storage Installation (ISFSI) for multi-year storage. To document the initial condition of the used fuel prior to emplacement in a storage system, “sister ” fuel rods will be harvested and sent to a national laboratory for characterization and archival purposes. This report supports the demonstration by describing how sister rods will be shipped and received at a national laboratory, and recommending basic nondestructive and destructive analyses to assure the fuel rods are adequately characterized for UFDC work. For this report, a hub-and-spoke model is proposed, with one location serving as the hub for fuel rod receipt and characterization. In this model, fuel and/or clad would be sent to other locations when capabilities at the hub were inadequate or nonexistent. This model has been proposed to reduce DOE-NE’s obligation for waste cleanup and decontamination of equipment.

  5. HIV, rods, and the muscles--a discussion about HIV-associated nemaline rod myopathy.

    Science.gov (United States)

    Madonia, Phillip; Wilson, Jon; Bican, Orhan; Willis, Megan; Bass, Pat

    2012-01-01

    This case reports a 21-year-old, homosexual African-American male who presented to our facility with a two-week history of progressive proximal muscle weakness. Quadriceps muscle biopsy showed a diagnosis of Nemaline Rod Myopathy, the presenting disease of his HIV infection. A review of the literature shows 13 prior case reports of similar disease process, often as the presenting symptom of the HIV disease. Anecdotal reports of effective treatment regimens include steroids and intravenous immune globulin; our patient had a profound response to high-dose steroids. This case report discusses this rare presentation of HIV in hopes to increase awareness amongst clinicians as the incidence and prevalence of HIV increases.

  6. Behaviour of lab parameters and neonatal weight loss in relation to neonatal breathing movements and cord clamping time.

    Science.gov (United States)

    Indraccolo, U; Santafata, R; Palazzetti, P L; Di Iorio, R; Indraccolo, S R

    2013-01-01

    To date, delaying cord clamping two to three minutes after birth is considered effective for newborn well-being. This time does not consider the newborn's breathing movements, which may also condition neonate well-being. To investigate the behaviour of neonatal weight loss and of some umbilical vein lab parameters, in relation to timing of newborn breathing and cord clamping. Time from birth to cord clamping and time from birth to first cry of the newborn were collected in 87 full-term healthy women. First cry is a sign of effective breathing. Birth weight loss at the first, second, and third day from birth and lab parameters were assessed in relation to: time from birth to cord clamping, time from birth to first cry, and cord clamping before or after the first cry. Partial pressure of carbon dioxide (pCO2) decreased if cord clamping was performed after first cry and increased if first cry occurred after cord clamping, independently from the time elapsed from birth to first cry (p = 0.012). Calcium (Ca(2+)) concentration decreased if cord clamping was performed after the first cry and increased if first cry of the baby after birth was delayed (p = 0.021). Each second of delay from birth to cord clamping resulted in an increase in Cl- concentration (p cord clamping resulted in a reduction in the percentage of weight loss at the first day (p = 0.024), at the second day (p = 0.007), and at the third day (p = 0.028) after birth. Neonate breathing after birth should induce umbilical vein flow from placenta to lungs, conditioning the reduction of birth weight loss after birth and umbilical lab parameters modifications.

  7. An observational study of umbilical cord clamping practices of maternity care providers in a tertiary care center.

    Science.gov (United States)

    Hutton, Eileen K; Stoll, Kathrin; Taha, Natalie

    2013-03-01

    Severing the umbilical cord at birth is likely the oldest intervention, the timing of which remains fraught with controversy. Emerging evidence suggests benefit in delaying cord clamping for both term and preterm infants. The objective of this study was to investigate actual cord clamping time and circumstances at a large tertiary care center in Canada. We used a stopwatch to time the interval from the time the infant was born as far as the umbilicus until the time that the umbilical cord was clamped before cutting. We reported on timing of the umbilical cord clamping overall and by practitioner group (obstetrician, midwife, and family practitioner). A total of 98 women and their practitioners consented to be observed at the British Columbia Women's Hospital and Health Center, Vancouver, Canada. More than one-half (56.2%) of all infants had their umbilical cord clamped within 15 seconds. The median (5th, 95th percentile) clamping time in seconds for the full sample was 12 (4, 402) with practitioner subgroups as follows: obstetricians (12 [3, 107]), family physicians (19 [6, 325]), and midwives (81 [6, undefined]). The median clamping time was likely to be longer when the birth occurred spontaneously, no umbilical cord blood was collected, and no birth or neonatal complications occurred. In our sample taken in 2006 to 2007, most infants had umbilical cords clamped immediately after the birth, with more than one-half clamped within 15 seconds of birth. Since the time of our study, delayed umbilical cord clamping for the healthy term newborn has become a part of recommended management of third stage of labor and resuscitation guidelines. It would be informative to repeat a study like this one to determine compliance with the current standards of care. © 2013, Copyright the Authors Journal compilation © 2013, Wiley Periodicals, Inc.

  8. Nuclear Fuel Test Rod Fabrication for Data Acquisition Test

    Energy Technology Data Exchange (ETDEWEB)

    Joung, Chang-Young; Hong, Jin-Tae; Kim, Ka-Hye; Huh, Sung-Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-10-15

    A nuclear fuel test rod must be fabricated with precise welding and assembly technologies, and confirmed for their soundness. Recently, we have developed various kinds of processing systems such as an orbital TIG welding system, a fiber laser welding system, an automated drilling system and a helium leak analyzer, which are able to fabricate the nuclear fuel test rods and rigs, and keep inspection systems to confirm the soundness of the nuclear fuel test rods and rids. The orbital TIG welding system can be used with two kinds of welding methods. One can perform the round welding for end-caps of a nuclear fuel test rod by an orbital head mounted in a low-pressure chamber. The other can do spot welding for a pin-hole of a nuclear fuel test rod in a high-pressure chamber to fill up helium gas of high pressure. The fiber laser welding system can weld cylindrical and 3 axis samples such as parts of a nuclear fuel test rod and instrumentation sensors which is moved by an index chuck and a 3 axis (X, Y, Z) servo stage controlled by the CNC program. To measure the real-time temperature change at the center of the nuclear fuel during the irradiation test, a thermocouple should be instrumented at that position. Therefore, a hole needs to be made at the center of fuel pellet to instrument the thermocouple. An automated drilling system can drill a fine hole into a fuel pellet without changing tools or breaking the work-piece. The helium leak analyzer (ASM-380 model of DEIXEN Co.) can check the leak of the nuclear fuel test rod filled with helium gas. This paper describes not only the assembly and fabrication methods used by the process systems, but also the results of the data acquisition test for the nuclear fuel test rod. A nuclear fuel test rod for the data acquisition test was fabricated using the welding and assembling echnologies acquired from previous tests.

  9. Exploration of Multifocal Rod Electroretinograms Recording in Human

    Institute of Scientific and Technical Information of China (English)

    Changzheng Chen; Lezheng Wu; De-Zheng Wu; Shixian Long; Jiongji Liang; Futian Jiang; Libing Jiang

    2002-01-01

    Purpose:To test the feasibility of recording rod multifocal electroretinograms (ERG) in humans and observe appropriate recording conditions.Methods: Multifocal rod ERG were recorded using a stimulus array of 61 equalsized hexagons in two normal subjects after the dark adaptation. Flashes were blue (W47B). Blank frames between two successive flashes of hexagons varied from 0 to 14. Length of the m-sequence, bandwidth, flash frequency, flash intensities and background intensities were changed to obtain appropriate recording conditions for the clinical use.Results:Multifocal rod ERG were clearly recordable and well formed. They had an early implicit time, very small negative wave and a late implicit time, large positive wave. The positive wave was bimodal, whose timing and waveform were similar to the full-field rod ERG. The local response amplitudes can be suppressed with increase in flash frequency or background intensity, decrease in flash intensity or the size of stimulus elements.Conclusions: Multifocal rod ERG can be recorded in human and can provide topographical maps of retinal function that have clinical usage. 212-1 m-sequence length, 3F blank frames and 3~ 300 Hz bandwidth were suggested to appropriate recording conditions.

  10. Nano-rods of zinc oxide in nano-graphene

    Science.gov (United States)

    Ortiz, Pedro; Chavira, Elizabeth; Monroy, Marel; Elizalde, José; Santiago, Patricia; Sato, Roberto; Tejeda, Adriana; González, Guillermina; Novelo, Omar; Flores, Carlos

    2014-03-01

    It's of great interest to study the devices based on nano-ZnO and graphene, for their electromagnetic and optical properties to increase the efficiency of solar cells. The graphene multilayers synthesis was done by mechanosynthesis, grinding in a mechanical agate mortar. The zinc oxide nano-rods were synthesized from zinc acetate dihydrate, Ace, (Sigma Aldrich) and ethylene diamine, En, (Sigma Aldrich) with a 1:2 ratio of reagents En/Ace. The ZnO nano-rods in nano-tubes graphene were obtained by mechanosynthesis. The X-ray powder diffraction, shows the shift of C with PDF 12-0212 and ZnO, Zincite PDF 36-1451, both with hexagonal unit cell. The grain size and morphology of graphene (multilayers and nano-tubes), ZnO nano-rods and ZnO-graphene mixture (multilayers, nano-tubes) were observed by scanning electron microscope. Transmission electron microscope, corroborates shown in SEM. Raman spectroscopy, shows the shift of multilayer graphene and the ZnO nano-rods. In photoluminescence measurements, observe the change in intensity in the band defects. Magnetic properties characterization was carried out by Vibrating Sample Magnetometry. We conclude that graphite multilayers dislocated by cutting efforts, forming graphene nano-tubes and encapsulated ZnO nano-rods within graphene.

  11. Finite Element Analysis of Connecting Rod of IC Engine

    Directory of Open Access Journals (Sweden)

    Samal Prasanta Kumar

    2015-01-01

    Full Text Available A connecting rod of IC engine is subjected to complex dynamic loading conditions. Therefore it is a critical machine element which attracts researchers’ attention. This paper aims at development of simple 3D model, finite element analyses and the optimization by intuition of the connecting rod for robust design. In this study the detailed load analysis under in-service loading conditions was performed for a typical connecting rod. The CAD model was prepared taking the detailed dimensions from a standard machine drawing text book. Based on the gas pressure variation in the cylinder of an IC engine, the piston forces were calculated for critical positions. MATLAB codes were written for this calculation. Altair Hypermesh and Hyperview were used for pre-processing and post-processing of the model respectively. The finite element analyses were performed using Altair Radioss. The results obtained were compared to a case study for the field failure of the connecting rod. By comparing the induced stress result with the yield strength of the material, the component was redesigned. This was done to save some mass keeping in mind that the induced stress value should be well below the yield strength of the material. The optimized connecting rod is 11.3% lighter than the original design.

  12. Dysprosium titanate as an absorber material for control rods

    Science.gov (United States)

    Risovany, V. D.; Varlashova, E. E.; Suslov, D. N.

    2000-09-01

    Disprosium titanate is an attractive control rod material for the thermal neutron reactors. Its main advantages are: insignificant swelling, no out-gassing under neutron irradiation, rather high neutron efficiency, a high melting point (˜1870°C), non-interaction with the cladding at temperatures above 1000°C, simple fabrication and easily reprocessed non-radioactive waste. It can be used in control rods as pellets and powder. The disprosium titanate control rods have worked off in the MIR reactor for 17 years, in VVER-1000 - for 4 years without any operating problems. After post-irradiation examinations this type of control rod having high lifetime was recommended for the VVER and RBMK. The paper presents the examination results of absorber element dummies containing dysprosium titanate, irradiated in the SM reactor to the neutron fluence of 3.4×10 22 cm -2 ( E>0.1 MeV) and, also, the data on structure, thermal-physical properties of dysprosium titanate, efficiency of dysprosium titanate control rods.

  13. Simulation on the HTTR Control Rod Withdrawal Test

    Energy Technology Data Exchange (ETDEWEB)

    Jun, Ji Su; Tak, Nam-il; Lim, Hong Sik [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    This paper describes the GAMMA+ code simulation of HTTR control rod withdrawal test. The simulation is done to examine the effect of GAMMA+ code's single-zone and multi-zone point kinetics models on the prediction of the reactor power response during HTTR control rod withdrawal test. In addition, it has an objective to examine how the reactor power response is affected by the application of the fuel temperature coefficients on TRISO kernel or compact rod. The calculation results of reactivity response and reactor power response are compared with the test results which were obtained at the initial power of 15.2 MW with the amount of reactivity insertion by control rod withdrawal to 3.4e-04 (dk/k) in 6.59 seconds. All GAMMA+ simulation results on a HTTR CRW test showed good predictions with the measured data. In particular, TRISO Kernel Model where the fuel temperature coefficients applied on the TRISO particle produced a better prediction within a 1.5% measured data and made no difference between the single-zone model and the multi-zone point kinetics model. During the control rod withdrawal event which is a fast transient, the total reactivity is mainly affected by the inserted reactivity and the reactivity response due to the change of the fuel temperature and the graphite moderator temperature.

  14. Control rod worth calculations using deterministic and stochastic methods

    Energy Technology Data Exchange (ETDEWEB)

    Varvayanni, M. [NCSR ' DEMOKRITOS' , PO Box 60228, 15310 Aghia Paraskevi (Greece); Savva, P., E-mail: melina@ipta.demokritos.g [NCSR ' DEMOKRITOS' , PO Box 60228, 15310 Aghia Paraskevi (Greece); Catsaros, N. [NCSR ' DEMOKRITOS' , PO Box 60228, 15310 Aghia Paraskevi (Greece)

    2009-11-15

    Knowledge of the efficiency of a control rod to absorb excess reactivity in a nuclear reactor, i.e. knowledge of its reactivity worth, is very important from many points of view. These include the analysis and the assessment of the shutdown margin of new core configurations (upgrade, conversion, refuelling, etc.) as well as several operational needs, such as calibration of the control rods, e.g. in case that reactivity insertion experiments are planned. The control rod worth can be assessed either experimentally or theoretically, mainly through the utilization of neutronic codes. In the present work two different theoretical approaches, i.e. a deterministic and a stochastic one are used for the estimation of the integral and the differential worth of two control rods utilized in the Greek Research Reactor (GRR-1). For the deterministic approach the neutronics code system SCALE (modules NITAWL/XSDRNPM) and CITATION is used, while the stochastic one is made using the Monte Carlo code TRIPOLI. Both approaches follow the procedure of reactivity insertion steps and their results are tested against measurements conducted in the reactor. The goal of this work is to examine the capability of a deterministic code system to reliably simulate the worth of a control rod, based also on comparisons with the detailed Monte Carlo simulation, while various options are tested with respect to the deterministic results' reliability.

  15. Substitute safety rods: Physics of operation and irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Baumann, N.P.

    1991-11-18

    Under certain assumed accidents, an SRS reactor may lose most of its bulk moderator while maintaining flow to fuel assemblies. If this occurs immediately after operation at power, components normally dependent on convective heat transfer to the moderator will heat up with the possibility of melting that component. One component at risk is the currently used cadmium safety rod. A substitute safety rod consisting solely of sintered B{sub 4}C and stainless steel has been designed which is capable of withstanding much higher temperatures. This memorandum provides the physics basis for the adequacy of the rod for reactor shutdown and provides a set of criteria for acceptance in the NTG tests. This memorandum provides physics data for other aspects of operation. These include: Heat production and helium production, along with related phenomena, resulting from inadvertent irradiation at power. Gamma heat input under drained tank conditions. An equivalent rod design suitable for charge design and safety analyses. Degradation under normal operation. Thermal flux ripple in adjacent fuel due to axial striping of alternate B{sub 4}C and steel pellets. Possible effect on safety analyses. Safety rod withdrawal during reactor startup.

  16. Plasmonic-cavity model for radiating nano-rod antennas

    DEFF Research Database (Denmark)

    Peng, Liang; Mortensen, N. Asger

    2014-01-01

    In this paper, we propose the analytical solution of nano-rod antennas utilizing a cylindrical harmonics expansion. By treating the metallic nano-rods as plasmonic cavities, we derive closed-form expressions for both the internal and the radiated fields, as well as the resonant condition and the ......In this paper, we propose the analytical solution of nano-rod antennas utilizing a cylindrical harmonics expansion. By treating the metallic nano-rods as plasmonic cavities, we derive closed-form expressions for both the internal and the radiated fields, as well as the resonant condition...... and the radiation efficiency. With our theoretical model, we show that besides the plasmonic resonances, efficient radiation takes advantage of (a) rendering a large value of the rods' radius and (b) a central-fed profile, through which the radiation efficiency can reach up to 70% and even higher in a wide...... frequency band. Our theoretical expressions and conclusions are general and pave the way for engineering and further optimization of optical antenna systems and their radiation patterns....

  17. Fault pseudotachylyte: a coseismic lightning rod

    Science.gov (United States)

    Ferre, E. C.; Conder, J. A.; MathanaSekaran, N.; Geissman, J. W.

    2013-12-01

    of melt during the formation of a pseudotachylite vein. The increase in melt temperature is the most important factor affecting electrical conductivity in the fault plane. When the melt temperature rises from 1300 to 2000K, its electrical conductivity increases about 80 times. This implies that once a continuous pseudotachylite sheet-like vein is formed during an earthquake, the vein has a much higher electrical conductivity than its host-rock. The dramatic increase in electrical conductivity along the pseudotachylite plane might be synchronous with the generation of the coseismic electrical current. Thus, regardless of its origin, any electrical current produced during an earthquake will travel along the pseudotachylite plane which acts as a lightning rod. The magnetization of a solid due to an electrical current results from Biot-Savart law which states that an electrical current generates a magnetic field. The solidification of the pseudotachylite vein does not happen at once but proceeds from the margin inwards as an electrical current may still pass through the conducting pseudotachylite. Therefore, the host-rock of the pseudotachylite vein or its solidified margin can be magnetized by a coseismic current.

  18. Off-clamp robot-assisted partial nephrectomy does not benefit short-term renal function: a matched cohort analysis.

    Science.gov (United States)

    Anderson, Barrett G; Potretzke, Aaron M; Du, Kefu; Vetter, Joel; Figenshau, R Sherburne

    2017-08-31

    In the interest of renal functional preservation, partial nephrectomy has supplanted radical nephrectomy as the preferred treatment for T1 renal masses. This procedure usually involves the induction of renal warm ischemia by clamping the hilar vessels prior to tumor excision. Performing robot-assisted partial nephrectomy (RAPN) "off-clamp" can theoretically prevent renal functional loss associated with warm ischemia. We describe our institutional experience and compare perioperative and renal functional outcomes using a propensity score matched cohort. We conducted a retrospective comparison from a prospectively maintained database of all patients who underwent RAPN from 2009 to 2015. Of those patients, 143 underwent off-clamp RAPN. Fifty off-clamp RAPN patients were propensity score matched with fifty clamped RAPN patients based on renal function, tumor size, and R.E.N.A.L. nephrometry score. The cohorts were compared across demographics, operative information, perioperative outcomes, and renal functional outcomes. For all off-clamp RAPN patients, mean nephrometry score was 7.1, mean estimated blood loss (EBL) was 236.9 mL, perioperative complication rate was 7.7%, and mean decrease in estimated glomerular filtration rate (eGFR) was 7.1% at a median follow-up of 9.2 months. In the propensity score matched cohorts, off-clamp RAPN resulted in a shorter mean operative time (172.0 versus 196.0 min, p = 0.025) and a lower mean EBL (179.7 versus 283.2 mL, p = 0.046). A lower complication rate of 6.0% in the off-clamp group compared with 20.0% in the clamped group approached significance (p = 0.071). Mean preoperative eGFR was similar in both cohorts. Importantly, there was no significant difference in decrease in eGFR between the clamped cohort (9.8%) and off-clamp cohort (11.9%) at a median follow-up of 9.0 months (p = 0.620). Off-clamp RAPN did not result in improved renal functional preservation in our experience. Surprisingly, the off-clamp cohort

  19. Induction of DNA DSB and its rejoining in clamped and non-clamped tumours after exposure to carbon ion beams in comparison to X rays.

    Science.gov (United States)

    Hirayama, R; Uzawa, A; Matsumoto, Y; Noguchi, M; Kase, Y; Takase, N; Ito, A; Koike, S; Ando, K; Okayasu, R; Furusawa, Y

    2011-02-01

    We studied double-strand breaks (DSB) induction and rejoining in clamped and non-clamped transplanted tumours in mice leg after exposure to 80 keV µm(-1) carbon ions and X rays. The yields of DSB in the tumours were analysed by a static-field gel electrophoresis. The OER of DSB after X rays was 1.68±0.31, and this value was not changed after 1 h rejoining time (1.40±0.26). These damages in oxygenated conditions were rejoined 60-70% within 1 h in situ. No difference was found between the exposure to X rays and carbon ions for the induction and rejoining of DSB. Thus, the values of OER and rejoined fraction after exposure to carbon ions were similar to those after X rays, and the calculated relative biological effectivenesses of carbon ion were around 1 under both oxygen conditions. The yields of DSB in vivo depend on exposure doses, oxygen conditions and rejoining time, but not on the types of radiation quality.

  20. Frequency domain analysis of lightning protection using four lightning protection rods

    Directory of Open Access Journals (Sweden)

    Javor Vesna

    2008-01-01

    Full Text Available In this paper the lightning discharge channel is modeled as a vertical monopole antenna excited by a pulse generator at its base. The lightning electromagnetic field of a nearby lightning discharge in the case of lightning protection using four vertical lightning protection rods was determined in the frequency domain. Unknown current distributions were determined by numerical solving of a system of integral equations of two potentials using the Point Matching Method and polynomial approximation of the current distributions. The influence of the real ground, treated as homogeneous loss half-space of known electrical parameters, expressed through a Sommerfeld integral kernel, was modeled using a new Two-image approximation which gives good results in both near and far fields.