WorldWideScience

Sample records for grounded wire source

  1. 30 CFR 77.701-3 - Grounding wires; capacity.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Grounding wires; capacity. 77.701-3 Section 77.701-3 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY... MINES Grounding § 77.701-3 Grounding wires; capacity. Where grounding wires are used to ground...

  2. Polarization dynamics in optical ground wire network.

    Science.gov (United States)

    Leeson, Jesse; Bao, Xiaoyi; Côté, Alain

    2009-04-20

    We report the polarization dynamics in an optical ground wire (OPGW) network for a summer period and a fall period for what is believed to be the first time. To better observe the surrounding magnetic fields contribution to modulating the state of polarization (SOP) we installed a Faraday rotating mirror to correct reciprocal birefringence from quasi-static changes. We also monitored the OPGW while no electrical current was present in the towers' electrical conductors. The spectral analysis, the arc length mapped out over a given time interval on a Poincaré sphere, histograms of the arc length, and the SOP autocorrelation function are calculated to analyze the SOP changes. Ambient temperature changes, wind, Sun-induced temperature gradients, and electrical current all have a significant impact on the SOP drift in an OPGW network. Wind-generated cable oscillations and Sun-induced temperature gradients are shown to be the dominant slow SOP modulations, while Aeolian vibrations and electrical current are shown to be the dominant fast SOP modulations. The spectral analysis revealed that the electrical current gives the fastest SOP modulation to be 300 Hz for the sampling frequency of 1 KHz. This has set the upper speed limit for real-time polarization mode dispersion compensation devices.

  3. New composite fiber-optic overhead ground wire

    Science.gov (United States)

    Nishiyama, S.; Kitayama, Y.; Ona, A.; Shimada, S.; Kikuta, T.

    1986-11-01

    A composite fiber-optic overhead ground wire (OPGW) has already been used commercially. Most of the electric power companies have the plans to establish new telecommunication networks by means of OPGW, and it is greatly needed to develop OPGW which has a maximum number of fibers for specific ground wire size with low transmission loss, easy handling and higher reliability. We have developed New OPGW, which satisfies these demands. It has the following features: (1) 18 fibers within 75 sq mm ground wire. (2) The fiber is a pure silica core and a fluorine-doped cladding single mode fiber with the average transmission loss of 0.4 dB/km at 1.3 micron. (3) Six fibers are stranded into a compact bunch and three bunches are housed in the spiral grooves of an aluminum spacer.

  4. Development of lightning-resistant overhead ground wire

    Energy Technology Data Exchange (ETDEWEB)

    Yokoya, Munehisa; Katsuragi, Yukio (Chubu Electric Power Co., Inc., Nagoya (Japan)); Goda, Yutaka (Central Research Inst. of the Electric Power Industry, Yokosuka (Japan)); Nagata, Yutaka; Asano, Yuji (Fujikura Ltd., Tokyo (Japan))

    1994-07-01

    Overhead ground wires (GW) are vulnerable to strand breakage due to lightning strikes. With the wider application in recent years of Composite Fiber Optic Ground Wire (OPGW), it becomes more important to protect GW from such damage. In this paper, the authors present the results of various investigations made in developing lightning-resistant GW/OPGW. Investigations included field experiments using rocket-triggered lightning, studies on materials and designs to improve lightning characteristics and various evaluation tests, such as DC arc tests, of several prototypes. As a result, the authors have developed excellent lightning-resistant GW/OPGW applicable for conventional transmission lines.

  5. 30 CFR 75.902-4 - Attachment of ground conductors and ground check wires to equipment frames; use of separate...

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Attachment of ground conductors and ground check wires to equipment frames; use of separate connections. 75.902-4 Section 75.902-4 Mineral... § 75.902-4 Attachment of ground conductors and ground check wires to equipment frames; use of...

  6. 30 CFR 77.902-3 - Attachment of ground conductors and ground check wires to equipment frames; use of separate...

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Attachment of ground conductors and ground check wires to equipment frames; use of separate connections. 77.902-3 Section 77.902-3 Mineral...-Voltage Alternating Current Circuits § 77.902-3 Attachment of ground conductors and ground check wires...

  7. New method for lightning location using optical ground wire

    Institute of Scientific and Technical Information of China (English)

    Zhaoyu Qin; Zhaogu Cheng; Zhiping Zhang; Jianqiang Zhu; Feng Li

    2006-01-01

    A new technology of lightning location is described, which is based on detecting the state of polarization(SOP) fluctuation of the laser light in the optic ground wire (OPGW). Compared with the conventional lightning location method, the new method is more accurate, more stable, and cheaper. Theories of Stokes generated by lightning strike can still be accurately identified by detecting the velocity of polarization motion. A new algorithm to quantify the velocity is also introduced.

  8. Energized overhead ground wires - OHGWs the pioneer Brazilian application

    Energy Technology Data Exchange (ETDEWEB)

    D`Ajuz, Ary; Martinez, Manuel L.B.; Araujo, Ana Maria R.; Takai, Mario Noboru; Sganzerla, Flavio [ELETRONORTE, Brasilia, DF (Brazil); O. Junior, Helio P.; Fonseca, Claudio S. [Marte Engenharia (Brazil); Guimaraes, R.P.; Mendes, Eloisa R.

    1994-12-31

    This paper introduces an economical solution for close HV lines small villages and farms load supply. The needed modifications to adapt a planned transmission system to supply loads located along the lines routes are presented. The paper describes the two overhead ground wires scheme planned for implementation in the 230 kV transmission line under construction by ELETRONORTE in Mato Grosso and Rondonia supplying loads each one totaling roughly 8 MW. (author) 4 refs., 4 figs., 2 tabs.

  9. Evaluation of Macrobend Loss on Long Distance Optical Ground Wire

    Directory of Open Access Journals (Sweden)

    M. F. M. Salleh

    2015-06-01

    Full Text Available Bend loss is a kind of loss that contributes to the power attenuation which is caused by the bending of optical fiber. For long distance optical fiber, bending might occur at joining point as there are many joining points along the link. Studies related to bend loss always relate the effect of bend radius on bend loss value. There is no study that relates the value of loss that can be affected by other factors like the natural environmental conditions. In this study, the evaluation of bend loss on existing long distance Optical Ground Wire (OPGW was studied since the cable was exposed to any climate condition.

  10. Considerations for fault current testing of optical ground wire

    Energy Technology Data Exchange (ETDEWEB)

    Madge, R.C.; Barrett, J.S.; Maruice, C.G. (Ontario Hydro, Toronto, ON (Canada). Research Div.)

    1992-10-01

    Optical Ground Wires (OPGW) are being used more frequently by utilities. However, fault current testing of OPGW has not been fully examined. In this paper, peak component temperatures are measured for both 10 m and 60 m spans. The cable temperature decay time is measured, and is compared against a numerical model of convection and conduction losses. A numerical model is developed to predict the peak cable tension following a hit. This model can be used to establish appropriate initial cable tensions to simulate full-span faults. The issue of dynamic stresses in the form of cable whipping is reviewed. Lastly, various cable termination procedures are tested.

  11. Optical ground wire for Hydro-Quebec`s telecommunication network

    Energy Technology Data Exchange (ETDEWEB)

    Ghannoum, E.; Chouteau, J.P.; Miron, M.; Yaacoub, S. [Hydro-Quebec, Montreal, Quebec (Canada); Yoshida, K.

    1995-10-01

    An extensive telecommunication network of 6,000 km of Optical Ground Wire (OPGW) is currently planned by Hydro-Quebec for progressive installation from 1992 to 2004. By 1994, about 1,600 km of OPGW have already been purchased and installed mostly on new 735 kV lines. This document provides information relative to the OPGW selection, characteristics, design, fabrication, and testing. Other sections are devoted to the installation experience, description of current and future R and D OPGW projects, and Authors` biography.

  12. Field trial of composite fiber-optic overhead ground wire

    Science.gov (United States)

    Kubota, S.; Kawahira, H.; Nakajima, T.; Matsubara, I.; Saito, Y.; Kitayama, Y.

    A composite fiber-optic ground wire (OPGW), which provides additional communication capabilities for system protection and control of overhead power transmission systems has been developed. After laboratory tests, the OPGW was strung along a live power transmission line in a mountainous region and has been confirmed to have sufficient performance to establish a high-speed digital transmission network able to withstand actual conditions. The field line, constructed substantially by existing techniques, has proved that the new OPGW, accessories such as clamps and joint boxes, installation technique, and on-tower splicing method can be effectively utilized to produce a protection and control system with extremely stable characteristics.

  13. New method for lightning location using optical ground wire

    Science.gov (United States)

    Qin, Zhaoyu; Cheng, Zhaogu; Zhang, Zhiping; Zhu, Jianqiang; Li, Feng

    2006-12-01

    A new technology of lightning location is described, which is based on detecting the state of polarization (SOP) fluctuation of the laser light in the optic ground wire (OPGW). Compared with the conventional lightning location method, the new method is more accurate, more stable, and cheaper. Theories of Stokes parameters and Poincare sphere are introduced to analyze the SOP at the lightning strike point. It can be concluded that although the initial points of SOP on the Poincare sphere are random, the SOP fluctuation generated by lightning strike can still be accurately identified by detecting the velocity of polarization motion. A new algorithm to quantify the velocity is also introduced.

  14. Influence of location of the lead wires on calculation results of grounding transient characteristics of a grounding rod

    Directory of Open Access Journals (Sweden)

    Kuklin D. V.

    2016-12-01

    Full Text Available For calculations and measurements of transient characteristics of groundings, the current and potential lead wires are frequently used accordingly to inject the current into the grounding and find the grounding potential rise (GPR. The results of the calculations and measurements can be dependent on the location of the current and potential lead wires due to mutual influence between them and the grounding wire. It is important to determine to what extent the location of the wires influences the calculation results for the grounding with a simple configuration. Notably, in contrast to the measurements, for the calculations it is possible to locate wires vertically, also the potential lead wire can be replaced by the integral of the electric field. For the calculations the finite difference time domain method (FDTD has been used in the work. In order to estimate to what extent the calculated GPR can be influenced by location of the wires, calculations with different wires locations have been carried out. An analysis of the calculation results has been made. There are calculation methods in which the injection of the current and calculation of the GPR are performed without the current and potential lead wires. The method based on the telegrapher's equations is one of such methods. In order to determine what location of the lead wires gives the same calculation results as those of the method that uses the telegrapher's equations, a comparison of calculation results of two methods has been made. Based on the calculation results it can be concluded that the calculated transient characteristics depend to a different extent on such factors as mutual location of the lead wires and the grounding wire, replacing the potential lead wire by the integral of the electric field, electrical parameters of the soil. Location of one of the lead wires above the grounding wire significantly reduces the calculated GPR. Calculation results for a perpendicular location

  15. Long term attenuation measurements on optical ground wires

    Energy Technology Data Exchange (ETDEWEB)

    Lamarche, L.; Gagnon, D.; Miron, M. [Hydro-Quebec, Varennes, Quebec1 (Canada)

    1996-11-01

    The attenuation stability of optical fibers integrated in optical ground wires (OPGW) cables over temperature and time is of paramount importance in the planning of long distance links. The authors report here a mean thermal attenuation dependence of 5.5{center_dot}10{sup {minus}5} dB/(km{center_dot}C) at 1,550 nm, on a 220 km span of dispersion shifted (DS) fibers of an installed OPGW cable. This optical link is installed in the James Bay region over a 735 kV power line where temperature varies from {minus}40 C to +30 C annually. The data sample presented covers 1.5 year starting December 1993. The data sample presented covers 1.5 year starting December 1993. During that period, the authors also observed a temporal evolution of the attenuation described by the empirical relation A = A{sub 0} (t{minus}t{sub 0}){sup 0.00394}.

  16. Evaluation of Fibre Lifetime in Optical Ground Wire Transmission Lines

    Science.gov (United States)

    Grunvalds, R.; Ciekurs, A.; Porins, J.; Supe, A.

    2017-06-01

    In the research, measurements of polarisation mode dispersion of two OPGWs (optical ground wire transmission lines), in total four fibres, have been carried out, and the expected lifetime of the infrastructure has been assessed on the basis of these measurements. The cables under consideration were installed in 1995 and 2011, respectively. Measurements have shown that polarisation mode dispersion values for cable installed in 1995 are four times higher than that for cable installed in 2011, which could mainly be explained by technological differences in fibre production and lower fibre polarisation mode dispersion requirements in 1995 due to lack of high-speed (over 10 Gbit/s) optical transmission systems. The calculation methodology of non-refusal work and refusal probabilities, using the measured polarisation mode dispersion parameters, is proposed in the paper. Based on reliability calculations, the expected lifetime is then predicted, showing that all measured fibres most likely will be operational within minimum theoretical service life of 25 years accepted by the industry.

  17. Ground-state energy of the electron liquid in ultrathin wires.

    Science.gov (United States)

    Fogler, Michael M

    2005-02-11

    The ground-state energy and the density correlation function of the electron liquid in a thin one-dimensional wire are computed. The calculation is based on an approximate mapping of the problem with a realistic Coulomb interaction law onto exactly solvable models of mathematical physics. This approach becomes asymptotically exact in the limit of a small wire radius but remains numerically accurate even for modestly thin wires.

  18. Photonic wires and trumpets for ultrabright single photon sources

    DEFF Research Database (Denmark)

    Gérard, Jean-Michel; Claudon, Julien; Bleuse, Joël

    2013-01-01

    Photonic wires have recently demonstrated very attractive assets in the field of high-efficiency single photon sources. After presenting the basics of spontaneous emission control in photonic wires, we compare the two possible tapering strategies that can be applied to their output end so...... as to tailor their radiation diagram in the far-field. We highlight the novel “photonic trumpet” geometry, which provides a clean Gaussian beam, and is much less sensitive to fabrication imperfections than the more common needle-like taper geometry. S4Ps based on a single QD in a PW with integrated bottom...... mirror and tapered tip display jointly a record-high efficiency (0.75±0.1 photon per pulse) and excellent single photon purity. Beyond single photon sources, photonic wires and trumpets appear as a very attractive resource for solid-state quantum optics experiments....

  19. High brightness single photon sources based on photonic wires

    DEFF Research Database (Denmark)

    Claudon, J.; Bleuse, J.; Bazin, M.

    2009-01-01

    We present a novel single-photon-source based on the emission of a semiconductor quantum dot embedded in a single-mode photonic wire. This geometry ensures a very large coupling (> 95%) of the spontaneous emission to the guided mode. Numerical simulations show that a photon collection efficiency...

  20. Compact wire array sources: power scaling and implosion physics.

    Energy Technology Data Exchange (ETDEWEB)

    Serrano, Jason Dimitri; Chuvatin, Alexander S. (Laboratoire du Centre National de la Recherche Scientifique Ecole Polytechnique, Palaiseau, France); Jones, M. C.; Vesey, Roger Alan; Waisman, Eduardo M.; Ivanov, V. V. (University of Nevada - Reno, Reno, NV); Esaulov, Andrey A. (University of Nevada - Reno, Reno, NV); Ampleford, David J.; Cuneo, Michael Edward; Kantsyrev, Victor Leonidovich (University of Nevada - Reno, Reno, NV); Coverdale, Christine Anne; Rudakov, L. I. (Icarus Research, Bethesda, MD); Jones, Brent Manley; Safronova, Alla S. (University of Nevada - Reno, Reno, NV); Vigil, Marcelino Patricio

    2008-09-01

    A series of ten shots were performed on the Saturn generator in short pulse mode in order to study planar and small-diameter cylindrical tungsten wire arrays at {approx}5 MA current levels and 50-60 ns implosion times as candidates for compact z-pinch radiation sources. A new vacuum hohlraum configuration has been proposed in which multiple z pinches are driven in parallel by a pulsed power generator. Each pinch resides in a separate return current cage, serving also as a primary hohlraum. A collection of such radiation sources surround a compact secondary hohlraum, which may potentially provide an attractive Planckian radiation source or house an inertial confinement fusion fuel capsule. Prior to studying this concept experimentally or numerically, advanced compact wire array loads must be developed and their scaling behavior understood. The 2008 Saturn planar array experiments extend the data set presented in Ref. [1], which studied planar arrays at {approx}3 MA, 100 ns in Saturn long pulse mode. Planar wire array power and yield scaling studies now include current levels directly applicable to multi-pinch experiments that could be performed on the 25 MA Z machine. A maximum total x-ray power of 15 TW (250 kJ in the main pulse, 330 kJ total yield) was observed with a 12-mm-wide planar array at 5.3 MA, 52 ns. The full data set indicates power scaling that is sub-quadratic with load current, while total and main pulse yields are closer to quadratic; these trends are similar to observations of compact cylindrical tungsten arrays on Z. We continue the investigation of energy coupling in these short pulse Saturn experiments using zero-dimensional-type implosion modeling and pinhole imaging, indicating 16 cm/?s implosion velocity in a 12-mm-wide array. The same phenomena of significant trailing mass and evidence for resistive heating are observed at 5 MA as at 3 MA. 17 kJ of Al K-shell radiation was obtained in one Al planar array fielded at 5.5 MA, 57 ns and we

  1. Analysis of overvoltages in overhead ground wires of extra high voltage (EHV) power transmission line under single-phase-to-ground faults

    NARCIS (Netherlands)

    Dudurych, [No Value; Rosolowski, E

    2000-01-01

    Overhead ground wires (GW) of extra high voltage (EHV) power transmission lines, apart from lightning-induced overvoltage protection are frequently used for carrier-current communication. In this case the ground wires are suspended on insulators, the dielectric strength of which should be sufficient

  2. VARIATIONAL CALCULATION ON GROUND-STATE ENERGY OF BOUND POLARONS IN PARABOLIC QUANTUM WIRES

    Institute of Scientific and Technical Information of China (English)

    WANG ZHUANG-BING; WU FU-LI; CHEN QING-HU; JIAO ZHENG-KUAN

    2001-01-01

    Within the framework of Feynman path-integral variational theory, we calculate the ground-state energy of a polaron in parabolic quantum wires in the presence of a Coulomb potential. It is shown that the polaronic correction to the ground-state energy is more sensitive to the electron-phonon coupling constant than the Coulomb binding parameter,and it increases monotonically with decreasing effective wire radius. Moreover, compared to the results obtained by Feynman Haken variational path-integral theory, we obtain better results within the Feynman path-integral variational approach (FV approach). Applying our calculation to several polar semiconductor quantum wires, we find that the polaronic correction can be considerably large.

  3. Wire-grid electromagnetic modelling of metallic cylindrical objects with arbitrary section, for Ground Penetrating Radar applications

    Science.gov (United States)

    Adabi, Saba; Pajewski, Lara

    2014-05-01

    Authors demonstrated that the well-known same-area criterion yields affordable results but is quite far from being the optimum: better results can be obtained with a wire radius shorter than what is suggested by the rule. In utility detection, quality controls of reinforced concrete, and other civil-engineering applications, many sought targets are long and thin: in these cases, two-dimensional scattering methods can be employed for the electromagnetic modelling of scenarios. In the present work, the freeware tool GPRMAX2D [6], implementing the Finite-Difference Time-Domain method, is used to implement the wire-grid modelling of buried two-dimensional objects. The source is a line of current, with Ricker waveform. Results obtained in [5] are confirmed in the time domain and for different geometries. The highest accuracy is obtained by shortening the radius of about 10%. It seems that fewer (and larger) wires need minor shortening; however, more detailed investigations are required. We suggest to use at least 8 - 10 wires per wavelength if the field scattered by the structure has to be evaluated. The internal field is much more sensitive to the modelling configuration than the external one, and more wires should be employed when shielding effects are concerned. We plan to conduct a more comprehensive analysis, in order to extract guidelines for wire sizing, to be validated on different shapes. We also look forward to verifying the possibility of using the wire-grid modelling method for the simulation of slotted objects. This work is a contribution to COST Action TU1208 "Civil Engineering Applications of Ground Penetrating Radar". The Authors thanks COST for funding COST Action TU1208. References [1] J.H. Richmond, A wire grid model for scattering by conducting bodies, IEEE Trans. Antennas Propagation AP-14 (1966), pp. 782-786. [2] S.M. Rao, D.R. Wilton, A.W. Glisson, Electromagnetic scattering by surfaces of arbitrary shape, IEEE Trans. Antennas Propagation AP-30 (1982

  4. Transient state of polarization in optical ground wire caused by lightning and impulse current

    Science.gov (United States)

    Kurono, Masahiro; Isawa, K.; Kuribara, Masayuki

    1996-08-01

    This paper describes a transient state of polarization in an optical ground wire (OPGW) theoretically, experimentally and with field measurements in lightning conditions, which is considered one of the fastest phenomena of polarization fluctuations in the natural environment. These characteristics will be required for optical coherent communication for utilities in future and for application to sensing of lightning with OPGW.

  5. Hybrid modelling of near-field coupling onto grounded wire under ultra-short duration perturbation

    Science.gov (United States)

    Ravelo, B.; Liu, Y.

    2014-10-01

    A time-frequency (TF) hybrid model (HM) for investigating the interaction between EM near-field (NF) aggression and grounded wire is addressed. The HM is based on the combination of techniques for extracting the EM NF radiated by electronic structures and the calculation of electrical disturbances across the wire due to EM coupling. The computation method is fundamentally inspired from transmission line (TL) theory under EM illumination. The methodology including flow chart interpreting the routine algorithm based on the combination of frequency and time domain approaches is featured. An experimental result showing the EM coupling between patch antenna-wire from 1.5-3.5GHz reveals the efficiency of the HM in frequency domain. The relevance of this HM was illustrated with a structure comprised of 20cm aggressor and 5cm victim I-shaped wires placed above a planar ground plane. The aggressor was excited with 40ns duration perturbation signal. After Matlab implementation of the HM, the disturbance voltages across the extremity of the victim wire were extracted. This simple and fast HM is useful for the EMC engineering during the design and fabrication phases of electrical and electronic systems.

  6. Multiple source ground heat storage

    Science.gov (United States)

    Belzile, P.; Lamarche, L.; Rousse, D. R.

    2016-09-01

    Sharing geothermal borefields is usually done with each borehole having the same inlet conditions (flow rate, temperature and fluid). The objective of this research is to improve the energy efficiency of shared and hybrid geothermal borefields by segregating heat transfer sources. Two models are briefly presented: The first model allows the segregation of the inlet conditions for each borefields; the second model allows circuits to be defined independently for each leg of double U-tubes in a borehole. An application couples residential heat pumps and arrays of solar collectors. Independent circuits configuration gave the best energy savings in a symmetric configuration, the largest shank spacing and with solar collectors functioning all year long. The boreholes have been shortened from 300 m to 150 m in this configuration.

  7. Ground as a possible heat pump source

    Energy Technology Data Exchange (ETDEWEB)

    Lazzarin, R. [Padova Univ. (Germany). Dipt. di Tecnica e Gestione die Istemi Industriali

    2001-06-01

    Heat pumps are devices that can increase the thermal level of heat taken from an available source. Their performances are usually very sensible to the temperatures. This is the reason why sources different from the outside air are welcome, since that source is thermally unfavourable. The ground is a possible very favourable source: temperature variations are damped in the ground so much the more deeper one descends. The variations are also delayed, so that in the coldest period one can find equality very good thermal levels. The two main used systems are: horizontal tubes at a depth between 0.8 and 1.5m and vertical tubes. This last technology has gained an increasing popularity with depths which are sometimes deeper than 100m. It interests a large volume of ground with a comparatively small surface area. It is a technology already widespread in Switzerland (where more than 15.000 ground heat pumps were installed in these years), Germany and Austria. It could be a very favourable technology also in Italy and other mediterranean countries both for the presence of good thermal levels underground with excellent characteristics of heat exchange and for the possible use of the ground as a suitable summer thermal sink. (orig.)

  8. The Way of Reducing Current Values in Optical Ground Wires at Asymmetrical Faults on Overhead Transmission Lines

    Directory of Open Access Journals (Sweden)

    Egamnazarov Georgiy

    2016-12-01

    Full Text Available Given the fact that the installing costs of an optical ground wire on overhead lines directly depend on its cross-section, which in turn depends on the level of fault current it should withstand, in order to reduce these current values in the optical ground wire, I suggested performing its isolated descents from the end towers of the line with its transition to an optical cable. The research was carried out on the example of a 500 kV overhead line in the National Electric Power Grid. The Method of Symmetrical Components for calculating asymmetrical fault currents was not used; therefore, calculations were carried out on the base of presenting the line as a multi-wire system for the considered case as a five-wire system (optical ground wire, steel ground wire, and three phase wires. Such approach allows taking into account the initial asymmetry of the line parameters and modeling any kind of asymmetrical faults. The analyses of calculated results were performed. The conclusive evidence that the optical ground wire isolated descents from the end towers of the line give the possibility of reducing the level of maximal fault current distribution values in it and therefore its cross section, is presented.

  9. Research on ground heat exchanger of Ground Source Heat Pump technique

    Institute of Scientific and Technical Information of China (English)

    LIU Dong-sheng; SUN You-hong; GAO Ke; WU Xiao-hang

    2004-01-01

    Ground Source Heat Pump technique and its operating principle are described in this paper. Ground heat exchanger is the key technique of ground source heat pump and its pattems are discussed. Software is helpful to design ground heat exchanger. A project of Chinese Ground Source Heat Pump is introduced and its market is more and more extensive.

  10. Characteristics of aerodynamic sound sources generated by coiled wires in a uniform air-flow

    Science.gov (United States)

    Matsumoto, H.; Nishida, K.; Saitoh, K.

    2003-11-01

    This study deals experimentally with aerodynamic sounds generated by coiled wires in a uniform air-flow. The coiled wire is a model of the hair dryer's heater. In the experiment, the effects of the coil diameter D, wire diameter d and coil spacing s of the coiled wire on the aerodynamic sound have been clarified. The results of frequency analyses of the aerodynamic sounds show that an Aeolian sound is generated by the coiled wire, when s/d is larger than 1. Also the peak frequencies of Aeolian sounds generated by the coiled wires are higher than the ones generated by a straight cylinder having the same diameter d. To clarify the characteristics of the aerodynamic sound sources, the directivity of the aerodynamic sound generated by the coiled wire has been examined, and the coherent function between the velocity fluctuation around the coiled wire and the aerodynamic sound has been calculated. Moreover, the band overall value of coherent output power between the sound and the velocity fluctuations has been calculated. This method has clarified the sound source region of the Aeolian sound generated by the coiled wire. These results show that the Aeolian sound is generated by the arc part of the coiled wire, which is located in the upstream side of the air-flow.

  11. Autonomous Inspection Robot for Power Transmission Lines Maintenance While Operating on the Overhead Ground Wires

    Directory of Open Access Journals (Sweden)

    Zheng Li

    2011-01-01

    Full Text Available This paper describes the development of a mobile robot capable of clearing such obstacles as counterweights, anchor clamps, and torsion tower. The mobile robot walks on overhead ground wires in 500KV power tower. Its ultimate purpose is to automate to inspect the defect of power transmission line. The robot with 13 motors is composed of two arms, two wheels, two claws, two wrists, etc. Each arm has 4 degree of freedom. Claws are also mounted on the arms. An embedded computer based on PC/104 is chosen as the core of control system. Visible light and thermal infrared cameras are installed to obtain the video and temperature information, and the communication system is based on wireless LAN TCP/IP protocol. A prototype robot was developed with careful considerations of mobility. The new sensor configuration is used for the claw to grasp the overhead ground wires. The bridge is installed in the torsion tower for the robot easy to cross obstacles. The new posture plan is proposed for obstacles cleaning in the torsion tower. Results of experiments demonstrate that the robot can be applied to execute the navigation and inspection tasks.

  12. Autonomous Inspection Robot for Power Transmission Lines Maintenance While Operating on the Overhead Ground Wires

    Directory of Open Access Journals (Sweden)

    Zheng Li

    2010-12-01

    Full Text Available This paper describes the development of a mobile robot capable of clearing such obstacles as counterweights, anchor clamps, and torsion tower. The mobile robot walks on overhead ground wires in 500KV power tower. Its ultimate purpose is to automate to inspect the defect of power transmission line. The robot with 13 motors is composed of two arms, two wheels, two claws, two wrists, etc. Each arm has 4 degree of freedom. Claws are also mounted on the arms. An embedded computer based on PC/104 is chosen as the core of control system. Visible light and thermal infrared cameras are installed to obtain the video and temperature information, and the communication system is based on wireless LAN TCP/IP protocol. A prototype robot was developed with careful considerations of mobility. The new sensor configuration is used for the claw to grasp the overhead ground wires. The bridge is installed in the torsion tower for the robot easy to cross obstacles. The new posture plan is proposed for obstacles cleaning in the torsion tower. Results of experiments demonstrate that the robot can be applied to execute the navigation and inspection tasks.

  13. Reflection of ground-source heat pump systems' application

    Institute of Scientific and Technical Information of China (English)

    ZHANGSuyun; LINZhenguo; WUXiangsheng; WUTian

    2003-01-01

    Ground-source heat pump system is an air-conditioning form of energy efficient and environment protection. This article introduced the forms of ground-source heat pump systems, analyzed the problems of ground-source heat pump systems in application in China, and put forward the solutions to these problems.

  14. Transverse Beam Halo Measurements at High Intensity Neutrino Source (HINS) using Vibrating Wire Monitor

    Energy Technology Data Exchange (ETDEWEB)

    Chung, M.; Hanna, B.; Scarpine, V.; Shiltsev, V.; Steimel, J.; Artinian, S.; Arutunian, S.

    2015-02-26

    The measurement and control of beam halos will be critical for the applications of future high-intensity hadron linacs. In particular, beam profile monitors require a very high dynamic range when used for the transverse beam halo measurements. In this study, the Vibrating Wire Monitor (VWM) with aperture 60 mm was installed at the High Intensity Neutrino Source (HINS) front-end to measure the transverse beam halo. A vibrating wire is excited at its resonance frequency with the help of a magnetic feedback loop, and the vibrating and sensitive wires are connected through a balanced arm. The sensitive wire is moved into the beam halo region by a stepper motor controlled translational stage. We study the feasibility of the vibrating wire for the transverse beam halo measurements in the low-energy front-end of the proton linac.

  15. Lightning current test of power ground wires with optical fibres (OPGW); Blitzstromfestigkeitspruefung von Erdseilen mit integrierten Lichtwellenleitern

    Energy Technology Data Exchange (ETDEWEB)

    Boehme, M. [VEW EuroTest GmbH, Dortmund (Germany); Moeller, K. [Technische Hochschule Aachen (Germany). Inst. fuer Allgemeine Elektrotechnik und Hochspannungstechnik; Nolden, W. [Felten und Guilleaume Energietechnik AG, Koeln (Germany)

    1998-09-21

    The area-wide application of ground wires with integrated optical fibers establishes a basis to use the existing overhead lines in addition to power supply also as communication networks. Taking in account the particular lightning stroke endangering of overhead lines a basic study of the thermal stress and damage progression of this ground wire type during a lightning stroke is necessary. (orig.) [Deutsch] Der Einsatz von Erdseilen mit integrierten Lichtwellenleitern schafft die Voraussetzung, bestehende Freileitungstrassen nicht nur zur Energieversorgung zu nutzen, sondern auch als Kommunikationsnetze zu betreiben. Unter Beruecksichtigung der besonderen Blitzeinschlagsgefaehrdung von Freileitungstrassen ist eine grundlegende Untersuchung der thermischen Beanspruchung und der Schadensentwicklung dieses Erdseiltyps waehrend eines Blitzeinschlags notwendig. (orig.)

  16. Very Efficient Single-Photon Sources Based on Quantum Dots in Photonic Wires

    DEFF Research Database (Denmark)

    Gerard, Jean-Michel; Claudon, Julien; Bleuse, Joel

    2014-01-01

    We review the recent development of high efficiency single photon sources based on a single quantum dot in a photonic wire. Unlike cavity-based devices, very pure single photon emission and efficiencies exceeding 0.7 photon per pulse are jointly demonstrated under non-resonant pumping conditions....... By placing a tip-shaped or trumpet-like tapering at the output end of the wire, a highly directional Gaussian far-field emission pattern is obtained. More generally, a photonic wire containing a quantum dot appears as an attractive template to explore and exploit in a solid-state system the unique optical...

  17. Wire position system to consistently measure and record the location change of girders following ground changes

    Science.gov (United States)

    Choi, H. J.; Lee, S. B.; Lee, H. G.; Y Back, S.; Kim, S. H.; Kang, H. S.

    2017-07-01

    Several parts that comprise the large scientific device should be installed and operated at the accurate three-dimensional location coordinates (X, Y, and Z) where they should be subjected to survey and alignment. The location of the aligned parts should not be changed in order to ensure that the electron beam parameters (Energy 10 GeV, Charge 200 pC, and Bunch Length 60 fs, Emittance X/Y 0.481 μm/0.256 μm) of PAL-XFEL (X-ray Free Electron Laser of the Pohang Accelerator Laboratory) remain stable and can be operated without any problems. As time goes by, however, the ground goes through uplift and subsidence, which consequently deforms building floors. The deformation of the ground and buildings changes the location of several devices including magnets and RF accelerator tubes, which eventually leads to alignment errors (∆X, ∆Y, and ∆Z). Once alignment errors occur with regard to these parts, the electron beam deviates from its course and beam parameters change accordingly. PAL-XFEL has installed the Hydrostatic Leveling System (HLS) to measure and record the vertical change of buildings and ground consistently and systematically and the Wire Position System (WPS) to measure the two dimensional changes of girders. This paper is designed to introduce the operating principle and design concept of WPS and discuss the current situation regarding installation and operation.

  18. The effect of randomly earthed ground wires on PLC transmission; A simulation experiment

    Energy Technology Data Exchange (ETDEWEB)

    Brandao Faria, J.A.; Borges da Silva, J.F. (Centro de Electrotecnia da Universidade Tecnica de Lisboa, Instituto Superior Tecnico, Dept. of Electrical Engineering, 1096 Lisboa Codex (PT))

    1990-10-01

    Power line ground wires are discretely bonded to earth along the line at each tower. When the spacing between towers is constant and approaches a multiple of one half wavelength at the operating frequency, abrupt variations in the propagation parameters occur, that would affect carrier transmission performance at the vicinity of certain critical frequencies. In practice the spacing between towers is not exactly constant and one may wish to know the result of taking this circumstance into account. The analysis and numerical results presented in this paper show that even slight random perturbations of line periodicity are sufficient to render unnoticeable any sharp variations in attenuation, velocity and surge impedance, one might be led to expect from the analysis of the strictly periodic case.

  19. Highly precise distributed Brillouin scattering sensor for structural health monitoring of optical ground wire cable

    Science.gov (United States)

    Zou, Lufan; Ravet, Fabien; Bao, Xiaoyi; Chen, Liang

    2004-07-01

    A distributed Brillouin scattering sensor with high special precision has been developed for the measurement of small damages/cracks of 1.5 cm. The out-layer damaged regions in an optical ground wire (OPGW) cable have been identified successfully by measuring the strain distributions every 5 cm using this technology. The stress increased to 127 kN which corresponds to more than 7500 micro-strain in the fibers. The locations of structural indentations comprising repaired and undamaged regions are found and distinguished using their corresponding strain data. The elongation of repaired region increases with time on 127 kN. These results are quantified in terms of the fiber orientation, stress, and behavior relative to undamaged sections.

  20. Ground-source Heat Pump Barometer

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-09-15

    The double whammy dealt by the economic crisis and housing slump has stifled expansion of the ground-source heat pump market in many European countries. The European Union market contracted for the second year running (by 2.9% between 2009 and 2010), and this despite the fact that more than 100,000 units were sold over the twelve-month period, taking the number of installed units past the one million mark. [French] La crise economique ainsi que la crise immobiliere qui touchent de nombreux pays europeens ne facilitent pas l'essor du marche de la pompe a chaleur geothermique. Pour la deuxieme annee consecutive, le marche de l'union europeenne est en baisse (-2,9 % entre 2009 et 2010). il parvient tout de meme a se maintenir au-dessus des 100 000 unites vendues par an, ce qui lui permet de depasser pour la premiere fois le cap du million d'unites installees.

  1. Optimal Ground Source Heat Pump System Design

    Energy Technology Data Exchange (ETDEWEB)

    Ozbek, Metin [ENVIRON; Yavuzturk, Cy [University of Hartford; Pinder, George [University of Vermont

    2015-04-15

    Despite the facts that GSHPs first gained popularity as early as the 1940’s and they can achieve 30 to 60 percent in energy savings and carbon emission reductions relative to conventional HVAC systems, the use of geothermal energy in the U.S. has been less than 1 percent of the total energy consumption. The key barriers preventing this technically-mature technology from reaching its full commercial potential have been its high installation cost and limited consumer knowledge and trust in GSHP systems to deliver the technology in a cost-effective manner in the market place. Led by ENVIRON, with support from University Hartford and University of Vermont, the team developed and tested a software-based a decision making tool (‘OptGSHP’) for the least-cost design of ground-source heat pump (‘GSHP’) systems. OptGSHP combines state of the art optimization algorithms with GSHP-specific HVAC and groundwater flow and heat transport simulation. The particular strength of OptGSHP is in integrating heat transport due to groundwater flow into the design, which most of the GSHP designs do not get credit for and therefore are overdesigned.

  2. Optimal Ground Source Heat Pump System Design

    Energy Technology Data Exchange (ETDEWEB)

    Ozbek, Metin [Environ Holdings Inc., Princeton, NJ (United States); Yavuzturk, Cy [Univ. of Hartford, West Hartford, CT (United States); Pinder, George [Univ. of Vermont, Burlington, VT (United States)

    2015-04-01

    Despite the facts that GSHPs first gained popularity as early as the 1940’s and they can achieve 30 to 60 percent in energy savings and carbon emission reductions relative to conventional HVAC systems, the use of geothermal energy in the U.S. has been less than 1 percent of the total energy consumption. The key barriers preventing this technically-mature technology from reaching its full commercial potential have been its high installation cost and limited consumer knowledge and trust in GSHP systems to deliver the technology in a cost-effective manner in the market place. Led by ENVIRON, with support from University Hartford and University of Vermont, the team developed and tested a software-based a decision making tool (‘OptGSHP’) for the least-cost design of ground-source heat pump (‘GSHP’) systems. OptGSHP combines state of the art optimization algorithms with GSHP-specific HVAC and groundwater flow and heat transport simulation. The particular strength of OptGSHP is in integrating heat transport due to groundwater flow into the design, which most of the GSHP designs do not get credit for and therefore are overdesigned.

  3. A narrow-band, variable energy ion source derived from a wire plasma source

    Energy Technology Data Exchange (ETDEWEB)

    Gueroult, R; Elias, P Q; Packan, D [ONERA Palaiseau, 91761 Palaiseau (France); Rax, J M, E-mail: renaud.gueroult@polytechnique.edu [LPP, Ecole Polytechnique, 91128 Palaiseau Cedex (France)

    2011-08-15

    A low pressure wire-induced plasma source (WIPS) operated in its high-pressure mode ({approx}10{sup -2} mbar) exhibits a narrow ion energy distribution function peaked at an energy corresponding to the discharge voltage. In order to take advantage of this peculiar feature, we design an electrode geometry enabling the acceleration of ions extracted from a WIPS. Probing of the obtained ion plume by means of a retarding potential analyser (RPA) demonstrates the capability of such an ion source to generate narrow-band (full width at half maximum of about 20 eV), variable energy (1 to 5 keV) ion beams. Comparison with particle-in-cell simulations of the WIPS shows that the energy spread of these ion beams is actually about 10 eV, the slight broadening being mainly the effect of the limited planar RPA energy resolution. The ion beam spot size measured at 6 cm of the ion source exit is about 3 mm for a 10 {mu}A He{sup +} beam at 2 keV, with a divergence of about one degree. Operating the WIPS in argon and xenon leads to similar properties for Ar{sup +} and Xe{sup +} beams, and in principle other species could also be used.

  4. Implementation and Applications of the Method of Auxiliary Sources for Analysis of Smooth Scatterers and Wires

    DEFF Research Database (Denmark)

    Larsen, Niels Vesterdal

    2007-01-01

    This report documents the implementation of Method of Auxiliary Sources techniques developed for smooth scatterers and wire scatterers. The work was done in the course of the PhD project "Electronically Steerable Antennas for Satellite Communication" where the techniques were employed to investig......This report documents the implementation of Method of Auxiliary Sources techniques developed for smooth scatterers and wire scatterers. The work was done in the course of the PhD project "Electronically Steerable Antennas for Satellite Communication" where the techniques were employed...

  5. A novel design method for ground source heat pump

    Directory of Open Access Journals (Sweden)

    Dong Xing-Jie

    2014-01-01

    Full Text Available This paper proposes a novel design method for ground source heat pump. The ground source heat pump operation is controllable by using several parameters, such as the total meters of buried pipe, the space between wells, the thermal properties of soil, thermal resistance of the well, the initial temperature of soil, and annual dynamic load. By studying the effect of well number and well space, we conclude that with the increase of the well number, the inlet and outlet water temperatures decrease in summer and increase in winter, which enhance the efficiency of ground source heat pump. The well space slightly affects the water temperatures, but it affects the soil temperature to some extent. Also the ground source heat pump operations matching with cooling tower are investigated to achieve the thermal balance. This method greatly facilitates ground source heat pump design.

  6. Asteroseismology with the WIRE satellite. I. Combining Ground- and Space-based Photometry of the Delta Scuti Star Epsilon Cephei

    CERN Document Server

    Bruntt, H; Bedding, T R; Buzasi, D L; Moya, A; Amado, P J; Martin-Ruiz, S; Garrido, R; De Coca, P L; Rolland, A; Costa, V; Olivares, I; Garcia-Pelayo, J M

    2006-01-01

    We have analysed ground-based multi-colour Stromgren photometry and single-filter photometry from the star tracker on the WIRE satellite of the delta scuti star Epsilon Cephei. The ground-based data set consists of 16 nights of data collected over 164 days, while the satellite data are nearly continuous coverage of the star during 14 days. The spectral window and noise level of the satellite data are superior to the ground-based data and this data set is used to locate the frequencies. However, we can use the ground-based data to improve the accuracy of the frequencies due to the much longer time baseline. We detect 26 oscillation frequencies in the WIRE data set, but only some of these can be seen clearly in the ground-based data. We have used the multi-colour ground-based photometry to determine amplitude and phase differences in the Stromgren b-y colour and the y filter in an attempt to identify the radial degree of the oscillation frequencies. We conclude that the accuracies of the amplitudes and phases a...

  7. New fault location system for power transmission lines using composite fiber-optic overhead ground wire (OPGW)

    Energy Technology Data Exchange (ETDEWEB)

    Urasawa, K. (Tokyo Electric Power Co., Inc. (Japan)); Kanemaru, K.; Toyota, S.; Sugiyama, K. (Hitachi Cable, Ltd., Tokyo (Japan))

    1989-10-01

    A new fault location (FL) method using composite fiber-optic overhead ground wires (OPGWs) is developed to find out where electrical faults occur on overhead power transmission lines. This method locates the fault section by detecting the current induced in the ground wire (GW), i.e. OPGW in this system. Since detected fault information is essentially uncertain, the new FL method treats the fault information oas a current distribution pattern throughout the power line, and applies Fuzzy Theory to realize the human-like manner of fault location used by electrical power engineers. It was confirmed by computer simulations that the fault section can be accurately located using this method under various conditions. This FL system has already been applied to several commercial power transmission lines and successfully located the sections where electrical faults occurred on actual power transmission lines.

  8. In Situ Measurement of the Undisturbed Ground Temperature for Ground Source Heat Pump System

    Institute of Scientific and Technical Information of China (English)

    ZHOU Ya-su

    2008-01-01

    The undisturbed ground are important for design of the ground heat exchangers in ground source heat pump (GSHP) systems. In this paper, the undisturbed ground temperatures measured in two different methods are presented. The investigation was carried out in two cases. The temperature measured with the direct method is assumed to give the correct undisturbed ground temperature profile. The temperature measured with indirect method overestimates the undisturbed ground temperature by 2.1℃ and 1.7℃. This difference is mainly caused by the circulation pump and ambient air to the fluid. Therefore, the results that are decreased about 2℃ as compared with the indirect measured are recommended to estimate the undisturbed ground temperature in situ measuring. A smaller pump or deeper borehole or mild weather would result in a more correct temperature. Because the undisturbed ground temperature is affected by many factors. Whether or not these conclusions are correct to other areas, this would need further investigation.

  9. Residential magnetic field: Accounting for external sources and residential grounding circuits

    Energy Technology Data Exchange (ETDEWEB)

    Barrow, D.A.

    1989-06-14

    A project to characterize the sources of magnetic fields in residential locations was established as part of Ontario Hydro's program to assess the risks, if any, posed by fields due to the electric power system. In this report, a simple model for the strength of the magnetic field at 60 Hz found inside houses is developed to account for the house wiring, and for sources external to the house. In the model the house wiring is reduced to a single circuit carrying the net current on the service drop to the house and the service grounding current. All sources external to the house are combined and represented as a single ambient field assumed to be spatially uniform throughout the volume of the house. This model and a measurmement procedure were tested on 5 houses in locations inside the houses remote from appliances, which were not included in the model. In the main, good agreement was found between actual measured field strengths and those predicted by the model. 4 refs., 10 figs., 6 tabs.

  10. North Village Ground Source Heat Pump Demonstration Project

    Energy Technology Data Exchange (ETDEWEB)

    Redderson, Jeff

    2015-08-03

    This project demonstrated the feasibility of converting from a traditional direct exchange system to a ground source heat pump system on a large scale, multiple building apartment complex on a university campus. A total of ten apartment buildings were converted using vertical well fields and a ground source loop that connected the 24 apartments in each building into a common system. The system has yielded significant operational savings in both energy and maintenance and transformed the living environments of these residential buildings for our students.

  11. Ground Source Geothermal District Heating and Cooling System

    Energy Technology Data Exchange (ETDEWEB)

    Lowe, James William [Ball State Univ., Muncie, IN (United States)

    2016-10-21

    Ball State University converted its campus from a coal-fired steam boiler district heating system to a ground source heat pump geothermal district system that produces simultaneously hot water for heating and chilled water for cooling. This system will include the installation of 3,600 four hundred feet deep vertical closed loop boreholes making it the largest ground source geothermal district system in the country. The boreholes will act as heat exchangers and transfer heat by virtue of the earth’s ability to maintain an average temperature of 55 degree Fahrenheit. With growing international concern for global warming and the need to reduce worldwide carbon dioxide loading of the atmosphere geothermal is poised to provide the means to help reduce carbon dioxide emissions. The shift from burning coal to utilizing ground source geothermal will increase electrical consumption but an overall decrease in energy use and reduction in carbon dioxide output will be achieved. This achievement is a result of coupling the ground source geothermal boreholes with large heat pump chiller technology. The system provides the thermodynamic means to move large amounts of energy with limited energy input. Ball State University: http://cms.bsu.edu/About/Geothermal.aspx

  12. Wind tunnel studies of gas dispersion from ground level source

    Directory of Open Access Journals (Sweden)

    Michálek Petr

    2015-01-01

    Full Text Available Measurements of gas dispersion from ground source were performed in a boundary layer wind tunnel in VZLU Prague. The measurements include non-buoyant gas dispersion behind a ground level source on a flat plane, on a simple rectangular building model and behind a model hill and rectangular barrier. These measurements will serve for verification of a new gas dispersion software being developed in VZLU. The dispersion model is intended for use by firemen and ambulance services in the case of an accident for immediate estimation of the area with dangerous gas concentration. The dispersion model will use precalculated results for chosen areas in the Czech Republic with industrial plants and residential building in the neighborhood. The size of contaminated area will be estimated using actual meteorological situation, i.e. wind speed and direction etc. and precalculated data of flow and dispersion in the chosen location.

  13. Wind tunnel studies of gas dispersion from ground level source

    Science.gov (United States)

    Michálek, Petr; Zacho, David

    2015-05-01

    Measurements of gas dispersion from ground source were performed in a boundary layer wind tunnel in VZLU Prague. The measurements include non-buoyant gas dispersion behind a ground level source on a flat plane, on a simple rectangular building model and behind a model hill and rectangular barrier. These measurements will serve for verification of a new gas dispersion software being developed in VZLU. The dispersion model is intended for use by firemen and ambulance services in the case of an accident for immediate estimation of the area with dangerous gas concentration. The dispersion model will use precalculated results for chosen areas in the Czech Republic with industrial plants and residential building in the neighborhood. The size of contaminated area will be estimated using actual meteorological situation, i.e. wind speed and direction etc. and precalculated data of flow and dispersion in the chosen location.

  14. A Miniaturized Linear Wire Ion Trap with Electron Ionization and Single Photon Ionization Sources

    Science.gov (United States)

    Wu, Qinghao; Tian, Yuan; Li, Ailin; Andrews, Derek; Hawkins, Aaron R.; Austin, Daniel E.

    2017-05-01

    A linear wire ion trap (LWIT) with both electron ionization (EI) and single photon ionization (SPI) sources was built. The SPI was provided by a vacuum ultraviolet (VUV) lamp with the ability to softly ionize organic compounds. The VUV lamp was driven by a pulse amplifier, which was controlled by a pulse generator, to avoid the detection of photons during ion detection. Sample gas was introduced through a leak valve, and the pressure in the system is shown to affect the signal-to-noise ratio and resolving power. Under optimized conditions, the limit of detection (LOD) for benzene was 80 ppbv using SPI, better than the LOD using EI (137 ppbv). System performance was demonstrated by distinguishing compounds in different classes from gasoline.

  15. On the resonance effects due to ground wires in transmission lines with non-uniform soil conductivity and non-uniform tower resistances

    Energy Technology Data Exchange (ETDEWEB)

    Faria, J.A. B. (Centro de Electrotecnia da Univ. Tecnica de Lisboa, Dept. of Electrical Engineering, Inst. Superior Tecnico, 1096 Lisboa Codex (PT))

    1992-01-01

    High frequency resonance effects due to shield wires grounding may affect carrier transmission performance at the vicinity of certain critical frequencies. In this paper the authors investigate if non-uniformities in soil conductivity and in tower footing resistances along the power line may lead to the suppression of such resonance effects. The simulation results the authors have obtained point towards a negative conclusion.

  16. Attenuation of ground vibrations due to different technical sources

    Institute of Scientific and Technical Information of China (English)

    L. Auersch; S. Said

    2010-01-01

    The attenuation of technically induced surface waves is studied theoretically and experimentally. In this paper, nineteen measurements of ground vibrations induced by eight different technical sources including road and rail traffic, vibratory and impulsive construction work or pile driving, explosions, hammer impulses and mass drops are described, and it is shown that the technically induced ground vibrations exhibit a power-law attenuation v ~ r where the exponents q are in the range of 0.5 to 2.0 and depend on the source types. Comparisons performed demonstrate that the measured exponents are considerably higher than theoretically expected. Some potential effects on ground vibration attenuation are theoretically analyzed. The most important effect is due to the material or scattering damping. Each frequency component is attenuated exponentially as exp(-kr), but for a broad-band excitation, the sum of the exponential laws also yields a power law but with a high exponent. Additional effects are discussed, for example the dispersion of the Rayleigh wave due to soil layering, which yields an additional exponent of 0.5 in cases of impulsive loading.

  17. Ground-source heat pump case studies and utility programs

    Energy Technology Data Exchange (ETDEWEB)

    Lienau, P.J.; Boyd, T.L.; Rogers, R.L.

    1995-04-01

    Ground-source heat pump systems are one of the promising new energy technologies that has shown rapid increase in usage over the past ten years in the United States. These systems offer substantial benefits to consumers and utilities in energy (kWh) and demand (kW) savings. The purpose of this study was to determine what existing monitored data was available mainly from electric utilities on heat pump performance, energy savings and demand reduction for residential, school and commercial building applications. In order to verify the performance, information was collected for 253 case studies from mainly utilities throughout the United States. The case studies were compiled into a database. The database was organized into general information, system information, ground system information, system performance, and additional information. Information was developed on the status of demand-side management of ground-source heat pump programs for about 60 electric utility and rural electric cooperatives on marketing, incentive programs, barriers to market penetration, number units installed in service area, and benefits.

  18. Experimental study of lightning protection effects to a overhead ground wire by a lightning rod and projection rods; Yuraishin oyobi dosshi wo mochiita kakuchisen no raigai boshi ni kansuru jikkenteki kento

    Energy Technology Data Exchange (ETDEWEB)

    Katsuragi, Y. [Chubu Electric Power Co. Inc., Nagoya (Japan); Aihara, Y. [Central Research Institute of Electric Power Industry, Tokyo (Japan)

    1995-04-20

    The overhead ground wire is generally used on transmission lines as one of the lightning protection devices for the power conductors. In recent years, the ground wire with an optical fiber cable in it (OPGW) has been employed on the transmission systems. The strands of the ground wire are, however, frequently melted down because of lightning strokes to them not only in summer but also in winter. For this reason, it is necessary to devise the new lightning protection method for the ground wire. As the protection method, lightning rods installed on the transmission tower arms and projection rods wound around a ground wire are proposed by authors. Lightning protection effects of these methods are shown by model experiments which simulate summer and winter lightning strokes. It has been made clear that these methods are useful as one of the lightning protection methods for transmission lines, and application conditions of them for practical use are also shown. 4 refs., 12 figs., 2 tabs.

  19. Earthquake Source and Ground Motion Characteristics of Great Kanto Earthquakes

    Science.gov (United States)

    Somerville, P. G.; Sato, T.; Wald, D. J.; Graves, R. W.; Dan, K.

    2003-12-01

    This paper describes the derivation of a rupture model of the 1923 Kanto earthquake, and the estimation of ground motions that occurred during that earthquake and that might occur during future great Kanto earthquakes. The rupture model was derived from the joint inversion of geodetic and teleseismic data. The leveling and triangulation data place strong constraints on the distribution and orientation of slip on the fault. The most concentrated slip is in the shallow central and western part of the fault. The location of the hypocenter on the western part of the fault gives rise to strong near fault rupture directivity effects, which are largest toward the east in the Boso Peninsula. To estimate the ground motions caused by this earthquake, we first calibrated 1D and 3D wave propagation path effects using the Odawara earthquake of 5 August 1990 (M 5.1), the first earthquake larger than M 5 in the last 60 years near the hypocenter of the 1923 Kanto earthquake. The simulation of the moderate-sized Odawara earthquake demonstrates that the 3D velocity model works quite well at reproducing the recorded long-period (T > 3.33 sec) strong motions, including basin-generated surface waves, for a number of sites located throughout the Kanto basin region. Using this validated 3D model along with the rupture model described above, we simulated the long-period (T > 4 sec) ground motions in this region for the 1923 Kanto earthquake. The largest ground motions occur east of the epicenter along the central and southern part of the Boso Peninsula. These large motions arise from strong rupture directivity effects and are comprised of relatively simple, source-controlled pulses with a dominant period of about 10 sec. Other rupture models and hypocenter locations generally produce smaller long period ground motion levels in this region that those of the 1923 event. North of the epicentral region, in the Tokyo area, 3D basin-generated phases are quite significant, and these phases

  20. Numerical analysis of complex impedance and microwave absorption of metamaterials composed of split cut wires on grounded dielectric substrate

    Science.gov (United States)

    Lim, Jun-Hee; Liu, Tian; Kim, Sung-Soo

    2014-06-01

    The microwave absorption of metamaterials composed of split cut wire (SCW) on grounded dielectric substrate has been investigated on the basis of equivalent transmission line circuit. S-parameters (S 11 and S 21) and input impedance are numerically simulated with variations of the thickness and dielectric loss of the substrate and the geometry of the SCW. Magnetic resonance resulting from antiparallel currents between SCW and ground plane was observed at the frequency of minimum reflection loss. The simulated resonance frequency and reflection loss can be explained well on the basis of the circuit theory of an LC resonator. Analysis of the input impedance of the high impedance surface has shown that perfect absorption can be obtained at the optimized impedance-matching condition, which is dependent on SCW width, thickness and the dielectric loss of the substrate. Better insight into the absorption mechanism of metamaterial absorbers can be attained through the parametric analysis on complex impedance of SCW and its relationship with reflection loss.

  1. Innovative commercial ``ground source'' heat pump system sources and sinks: Engineering and economics

    Energy Technology Data Exchange (ETDEWEB)

    Sachs, H.M.; Lowenstein, A.I.; Henderson, H.I. Jr.; Carlson, S.W.; Risser, J.E.

    1998-07-01

    Geothermal heat pumps, which will be called GX systems in this paper, have been employed in specialty applications on both residential and commercial buildings for several decades. GX systems generally have very competitive life cycle costs, but somewhat higher initial costs. The incremental cost of the ground heat exchanger cost is close to the average cost per ton, so GX systems work best with very efficient building shells. Innovative methods can reduce the ground heat exchanger cost. These include better coupling of the heat exchange boreholes to the ground, hybrid systems that use low cost closed fluid coolers to supplement the ground heat exchanger where cooling loads dominate, open loop systems, and opportunistic systems that use sewage effluent or other non-standard sources for heat exchange. These approaches and their benefits are illustrated through five case studies.

  2. New source of colour coded signal wire sleeving for cryogenic applications

    Science.gov (United States)

    Putnam, A. M.

    Wire sleeving made from Pb core nylon fishing line is presented. Signal wires can easily be sheathed in the nylon outer of weighted trolling line by drawing them through the outer attached to the core. Such line comes with a selection of colours on a single spool.

  3. A novel approach for the adsorption of iodine-125 on silver wire as matrix for brachytherapy source for the treatment of eye and prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Mathew, C.; Majali, M.A. E-mail: mythili@magnum.barc.ernet.in; Balakrishnan, S.A

    2002-09-01

    The adsorption of iodine-125 on silver wire bits coated with palladium to be sealed in titanium capsules as brachytherapy sources was studied. A method was optimized to obtain quantitative adsorption of {sup 125}I on the palladium treated silver wires. A comparative evaluation of palladium coated and uncoated (bare) silver wires on the adsorption of {sup 125}I was made. While, the adsorption of bare silver wires showed low, inconsistent uptake ({approx}60%) of {sup 125}I with high leachability ({approx}4%), the Pd coated silver wires showed quantitative and consistent uptake of {sup 125}I ({approx}90%) and exhibited low leachability (0.01%). {sup 125}I adsorbed on Pd coated silver wires could be used as a matrix for the preparation of interstitial sources in eye and prostate cancer therapy.

  4. Contrasting physics in wire array z pinch sources of 1-20 keV emission on the Z facilitya)

    Science.gov (United States)

    Ampleford, D. J.; Jones, B.; Jennings, C. A.; Hansen, S. B.; Cuneo, M. E.; Harvey-Thompson, A. J.; Rochau, G. A.; Coverdale, C. A.; Laspe, A. R.; Flanagan, T. M.; Moore, N. W.; Sinars, D. B.; Lamppa, D. C.; Harding, E. C.; Thornhill, J. W.; Giuliani, J. L.; Chong, Y.-K.; Apruzese, J. P.; Velikovich, A. L.; Dasgupta, A.; Ouart, N.; Sygar, W. A.; Savage, M. E.; Moore, J. K.; Focia, R.; Wagoner, T. C.; Killebrew, K. L.; Edens, A. D.; Dunham, G. S.; Jones, M. C.; Lake, P. W.; Nielsen, D. S.; Wu, M.; Carlson, A. L.; Kernahan, M. D.; Ball, C. R.; Scharberg, R. D.; Mulville, T. D.; Breden, E. W.; Speas, C. S.; Olivas, G.; Sullivan, M. A.; York, A. J.; Justus, D. W.; Cisneros, J. C.; Strizic, T.; Reneker, J.; Cleveland, M.; Vigil, M. P.; Robertson, G.; Sandoval, D.; Cox, C.; Maurer, A. J.; Graham, D. A.; Huynh, N. B.; Toledo, S.; Molina, L. P.; Lopez, M. R.; Long, F. W.; McKee, G. R.; Porter, J. L.; Herrmann, M. C.

    2014-05-01

    Imploding wire arrays on the 20 MA Z generator have recently provided some of the most powerful and energetic laboratory sources of multi-keV photons, including ∼375 kJ of Al K-shell emission (hν ∼ 1-2 keV), ∼80 kJ of stainless steel K-shell emission (hν ∼ 5-9 keV) and a kJ-level of Mo K-shell emission (hν ∼ 17 keV). While the global implosion dynamics of these different wire arrays are very similar, the physical process that dominates the emission from these x-ray sources fall into three broad categories. Al wire arrays produce a column of plasma with densities up to ∼3 × 1021 ions/cm3, where opacity inhibits the escape of K-shell photons. Significant structure from instabilities can reduce the density and increase the surface area, therefore increase the K-shell emission. In contrast, stainless steel wire arrays operate in a regime where achieving a high pinch temperature (achieved by thermalizing a high implosion kinetic energy) is critical and, while opacity is present, it has less impact on the pinch emissivity. At higher photon energies, line emission associated with inner shell ionization due to energetic electrons becomes important.

  5. Loss concentration and evacuation by mini-wire-septa from circular machines for spallation neutron sources

    CERN Document Server

    Schönauer, Horst Otto

    1996-01-01

    Efficient loss management is crucial in high-intensity circular machines like neutron sources, and those using superconducting magnets. Collimator systems have been designed or are under intensive study [1]. The common problem of collimation is the outscattering from the collimator faces which are most frequently hit at shallow depth. In this situation high collection efficiency can only be achieved by two-or-more-stage, double-jaw, systems requiring betatron phase advances approaching 2p. As the outscattering is isotropic, both transverse planes are affected and the system layout becomes a two-dimensional problem. Any convincing single-stage collimation system would be simpler to operate and is likely to be less expensive. The possible physical evacuation of the lost beam towards a remote dump can drastically reduce the radioactivity level in the tunnel. Moreover, fitting a two-stage system into an existing machine is difficult and in general not very promising. In this situation a wire septum may be the onl...

  6. Explosion source strong ground motions in the Mississippi embayment

    Science.gov (United States)

    Langston, C.A.; Bodin, P.; Powell, C.; Withers, M.; Horton, S.; Mooney, W.

    2006-01-01

    Two strong-motion arrays were deployed for the October 2002 Embayment Seismic Excitation Experiment to study the spatial variation of strong ground motions in the deep, unconsolidated sediments of the Mississippi embayment because there are no comparable strong-motion data from natural earthquakes in the area. Each linear array consisted of eight three-component K2 accelerographs spaced 15 m apart situated 1.2 and 2.5 kin from 2268-kg and 1134-kg borehole explosion sources, respectively. The array data show distinct body-wave and surface-wave arrivals that propagate within the thick, unconsolidated sedimentary column, the high-velocity basement rocks, and small-scale structure near the surface. Time-domain coherence of body-wave and surface-wave arrivals is computed for acceleration, velocity, and displacement time windows. Coherence is high for relatively low-frequency verticalcomponent Rayleigh waves and high-frequency P waves propagating across the array. Prominent high-frequency PS conversions seen on radial components, a proxy for the direct S wave from earthquake sources, lose coherence quickly over the 105-m length of the array. Transverse component signals are least coherent for any ground motion and appear to be highly scattered. Horizontal phase velocity is computed by using the ratio of particle velocity to estimates of the strain based on a plane-wave-propagation model. The resulting time-dependent phase-velocity map is a useful way to infer the propagation mechanisms of individual seismic phases and time windows of three-component waveforms. Displacement gradient analysis is a complementary technique for processing general spatial-array data to obtain horizontal slowness information.

  7. 40 CFR 141.402 - Ground water source microbial monitoring and analytical methods.

    Science.gov (United States)

    2010-07-01

    ... Rule § 141.402 Ground water source microbial monitoring and analytical methods. (a) Triggered source water monitoring—(1) General requirements. A ground water system must conduct triggered source water... State, systems must submit for State approval a triggered source water monitoring plan that identifies...

  8. Quantum Optics with Quantum Dots in Photonic Wires: Basics and Application to “Ultrabright” Single Photon Sources

    DEFF Research Database (Denmark)

    Gérard, J. M.; Claudon, J.; Bleuse, J.

    2011-01-01

    We review recent experimental and theoretical results, which highlight the strong interest of the photonic wire (PW) geometry for quantum optics experiments with solid-state emitters, and for quantum optoelectronic devices. By studying single InAs QDs embedded within single-mode cylindrical GaAs PW......, we have noticeably observed a very strong (16 fold) inhibition of their spontaneous emission rate in the thin-wire limit, and a nearly perfect funnelling of their spontaneous emission into the guided mode for larger PWs. We present a novel single -photon-source based on the emission of a quantum dot...... embedded in an engineered PW, comprising a tapered tip so as to control the radiation pattern, and an integrated hybrid bottom mirror. Unlike microcavity-based devices, this source displays for the first time simultaneously a record-high efficiency (0.73 photon per pulse) and a very low g(2) parameter...

  9. Clinical Study of Intra-operative Computed Tomography Guided Localization with A Hook-wire System for Small Ground Glass Opacities in Minimally Invasive Resection

    Directory of Open Access Journals (Sweden)

    Xiangyang CHU

    2014-12-01

    Full Text Available Background and objective Localization of pulmonary ground glass small nodule is the technical difficulty of minimally invasive operation resection. The aim of this study is to evaluate the value of intraoperative computed tomography (CT-guided localization using a hook-wire system for small ground glass opacity (GGO in minimally invasive resection, as well as to discuss the necessity and feasibility of surgical resection of small GGOs (<10 mm through a minimally invasive approach. Methods The records of 32 patients with 41 small GGOs who underwent intraoperative CT-guided double-thorn hook wire localization prior to video-assisted thoracoscopic wedge resection from October 2009 to October 2013 were retrospectively reviewed. All patients received video-assisted thoracoscopic surgery (VATS within 10 min after wire localization. The efficacy of intraoperative localization was evaluated in terms of procedure time, VATS success rate, and associated complications of localization. Results A total of 32 patients (15 males and 17 females underwent 41 VATS resections, with 2 simultaneous nodule resections performed in 3 patients, 3 lesion resections in 1 patient, and 5 lesions in a patient. Nodule diameters ranged from 2 mm-10 mm (mean: 5 mm. The distance of lung lesions from the nearest pleural surfaces ranged within 5 mm-24 mm (mean: 12.5 mm. All resections of lesions guided by the inserted hook wires were successfully performed by VATS (100% success rate. The mean procedure time for the CT-guided hook wire localization was 8.4 min (range: 4 min-18 min. The mean procedure time for VATS was 32 min (range: 14 min-98 min. The median hospital time was 8 d (range: 5 d-14 d. Results of pathological examination revealed 28 primary lung cancers, 9 atypical adenomatous hyperplasia, and 4 nonspecific chronic inflammations. No major complication related to the intraoperative hook wire localization and VATS was noted. Conclusion Intraoperative CT-guided hook wire

  10. Diagnostics of underwater electrical wire explosion through a time- and space-resolved hard x-ray source

    Energy Technology Data Exchange (ETDEWEB)

    Sheftman, D.; Shafer, D.; Efimov, S.; Gruzinsky, K.; Gleizer, S.; Krasik, Ya. E. [Physics Department, Technion, Haifa 32000 (Israel)

    2012-10-15

    A time- and space-resolved hard x-ray source was developed as a diagnostic tool for imaging underwater exploding wires. A {approx}4 ns width pulse of hard x-rays with energies of up to 100 keV was obtained from the discharge in a vacuum diode consisting of point-shaped tungsten electrodes. To improve contrast and image quality, an external pulsed magnetic field produced by Helmholtz coils was used. High resolution x-ray images of an underwater exploding wire were obtained using a sensitive x-ray CCD detector, and were compared to optical fast framing images. Future developments and application of this diagnostic technique are discussed.

  11. Modular design of multi-wire moderator for slow positron source on hard synchrotron radiation SPring-8

    CERN Document Server

    Nikitin, V P; Doronina, P P

    2001-01-01

    One of the optional versions of multi-wire moderator design using modular approach of construction is discussed. The methods of cleaning of tungsten wire surface are reviewed with the aim of increasing reemitted positron yield from moderator wires.

  12. Ground Source Integrated Heat Pump (GS-IHP) Development

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, V. D. [ORNL; Rice, K. [ORNL; Murphy, R. [ORNL; Munk, J. [ORNL; Ally, Moonis [ORNL; Shen, Bo [ORNL; Craddick, William [ORNL; Hearn, Shawn A. [ClimateMaster, Inc.

    2013-05-24

    Between October 2008 and May 2013 ORNL and ClimateMaster, Inc. (CM) engaged in a Cooperative Research and Development Agreement (CRADA) to develop a groundsource integrated heat pump (GS-IHP) system for the US residential market. A initial prototype was designed and fabricated, lab-tested, and modeled in TRNSYS (SOLAR Energy Laboratory, et al, 2010) to predict annual performance relative to 1) a baseline suite of equipment meeting minimum efficiency standards in effect in 2006 (combination of air-source heat pump (ASHP) and resistance water heater) and 2) a state-of-the-art (SOA) two-capacity ground-source heat pump with desuperheater water heater (WH) option (GSHPwDS). Predicted total annual energy savings, while providing space conditioning and water heating for a 2600 ft{sup 2} (242 m{sup 2}) house at 5 U.S. locations, ranged from 52 to 59%, averaging 55%, relative to the minimum efficiency suite. Predicted energy use for water heating was reduced 68 to 78% relative to resistance WH. Predicted total annual savings for the GSHPwDS relative to the same baseline averaged 22.6% with water heating energy use reduced by 10 to 30% from desuperheater contributions. The 1st generation (or alpha) prototype design for the GS-IHP was finalized in 2010 and field test samples were fabricated for testing by CM and by ORNL. Two of the alpha units were installed in 3700 ft{sup 2} (345 m{sup 2}) houses at the ZEBRAlliance site in Oak Ridge and field tested during 2011. Based on the steady-state performance demonstrated by the GS-IHPs it was projected that it would achieve >52% energy savings relative to the minimum efficiency suite at this specific site. A number of operational issues with the alpha units were identified indicating design changes needed to the system before market introduction could be accomplished. These were communicated to CM throughout the field test period. Based on the alpha unit test results and the diagnostic information coming from the field test

  13. The wire array Z-pinch: an efficient x-ray source for ICF and a new ion heating mechanism

    Science.gov (United States)

    Haines, M. G.

    2008-10-01

    The Z-pinch provides an efficient x-ray source for driving a hohlraum for inertial confinement fusion. The basic physics of wire-array implosions is reviewed. It can be understood in several sequential stages. Firstly, the wires heat and form a surrounding vapour which ionizes, causing the current to transfer to this lower resistance. The J×B global force leads to ejection of this plasma towards the axis to form a precursor plasma. The wire cores continue to ablate due to the heat flux from the Joule-heated nearby plasma. The cooling of this plasma by the wire-cores leads to a low magnetic Reynolds number so that the precursor plasma carries little or no current. When gaps appear in the liquid/vapour cores the plasma temperature and Reynolds number rise and this plasma accelerates in towards the axis carrying the current. This is the main implosion, and it sweeps up earlier ablated plasma, which acts to reduce Rayleigh-Taylor growth. At stagnation, the ion kinetic energy is thermalized and equipartition heats the electrons, which then radiate in a 5 ns pulse. In some conditions the energy radiated by soft x-rays exceeds the ion kinetic energy by a factor of 3 or 4. A theory has been developed to explain this in which fine-scale, fast growing m= 0 MHD instabilities grow to saturation, viscous dissipation of which leads to ion heating, followed by equipartition. World record ion temperatures of 2-3 billion Kelvin were predicted, and measured at Sandia National Laboratory. Lastly, progress in capsule implosions and in application to inertial fusion energy is reported.

  14. The Wire Array Z-Pinch AN Efficient X-Ray Source for Icf and a New Ion Heating Mechanism

    Science.gov (United States)

    Haines, M. G.

    2009-07-01

    The Z-pinch provides an efficient x-ray source for driving a hohlraum for inertial confinement fusion. The basic physics of wire-array implosions is reviewed. It can be understood in several sequential stages. First, the wires heat and form a surrounding vapor which ionizes, causing the current to transfer to this lower resistance. The J×B global force leads to ejection of this plasma towards the axis to form a precursor plasma. The wire cores continue to ablate due to the heat flux from the Joule-heated nearby plasma. The cooling of this plasma by the wire-cores leads to a low magnetic Reynolds number so that the precursor plasma carries little or no current. When gaps appear in the liquid/vapor cores the plasma temperature and Reynolds' number rise and this plasma accelerates in towards the axis carrying the current. This is the main implosion, and it sweeps up earlier ablated plasma, which acts to reduce Rayleigh-Taylor growth. At stagnation the ion kinetic energy is thermalised and equipartition heats the electrons, which then radiate in a 5 ns pulse. In some conditions the energy radiated as soft x-rays exceeds the ion kinetic energy by a factor of 3 or 4. A theory has been developed to explain this in which fine-scale, fast growing m = 0 MHD instabilities grow to saturation, viscous dissipation of which leads to ion heating, followed by equipartition. World record ion temperatures of 2 to 3 billion Kelvin were predicted, and measured at Sandia National Laboratory. Lastly progress in capsule implosions and in application to inertial fusion energy is reported.

  15. Investigation of direct expansion in ground source heat pumps

    Science.gov (United States)

    Kalman, M. D.

    A fully instrumented subscale ground coupled heat pump system was developed, and built, and used to test and obtain data on three different earth heat exchanger configurations under heating conditions (ground cooling). Various refrigerant flow control and compressor protection devices were tested for their applicability to the direct expansion system. Undistributed Earth temperature data were acquired at various depths. The problem of oil return at low evaporator temperatures and low refrigerant velocities was addressed. An analysis was performed to theoretically determine what evaporator temperature can be expected with an isolated ground pipe configuration with given length, pipe size, soil conditions and constant heat load. Technical accomplishments to data are summarized.

  16. Spent coffee grounds as a versatile source of green energy.

    Science.gov (United States)

    Kondamudi, Narasimharao; Mohapatra, Susanta K; Misra, Mano

    2008-12-24

    The production of energy from renewable and waste materials is an attractive alternative to the conventional agricultural feed stocks such as corn and soybean. This paper describes an approach to extract oil from spent coffee grounds and to further transesterify the processed oil to convert it into biodiesel. This process yields 10-15% oil depending on the coffee species (Arabica or Robusta). The biodiesel derived from the coffee grounds (100% conversion of oil to biodiesel) was found to be stable for more than 1 month under ambient conditions. It is projected that 340 million gallons of biodiesel can be produced from the waste coffee grounds around the world. The coffee grounds after oil extraction are ideal materials for garden fertilizer, feedstock for ethanol, and as fuel pellets.

  17. Investigation of lauric acid dopant as a novel carbon source in MgB 2 wire

    Science.gov (United States)

    Lee, C. M.; Lee, S. M.; Park, G. C.; Joo, J.; Lim, J. H.; Kang, W. N.; Yi, J. H.; Jun, B.-H.; Kim, C.-J.

    2010-11-01

    We fabricated lauric acid (LA) doped MgB2 wires and investigated the effects of the LA doping. For the fabrication of the LA-doped MgB2 wires, B powder was mixed with LA at 0-5 wt.% of the total amount of MgB2 using an organic solvent, dried, and then the LA-treated B and Mg powders were mixed stoichiometrically. The powder mixture was loaded into an Fe tube and the assemblage was drawn and sintered at 900 °C for 3 h under an argon atmosphere. We observed that the LA doping induced the substitution of C for the B sites in MgB2 and that the actual content of C increased monotonically with increasing LA doping level. The LA-doped MgB2 wires exhibited a lower critical temperature (Tc), but better critical current density (Jc) behavior in a high magnetic field: the 5 wt.% LA-doped sample had a Jc value of 5.32 × 103 A/cm2, which was 2.17 times higher than that of the pristine sample (2.45 × 103 A/cm2) at 5 K and 6 T, suggesting that LA is an effective C dopant in MgB2 for enhancing the high-field Jc performance.

  18. Temperature and Humidity Independent Control Research on Ground Source Heat Pump Air Conditioning System

    Science.gov (United States)

    Chen, G.; Wang, L. L.

    Taking green demonstration center building air conditioning system as an example, this paper presents the temperature and humidity independent control system combined with ground source heat pump system, emphasis on the design of dry terminal device system, fresh air system and ground source heat pump system.

  19. Time domain analysis of thin-wire antennas over lossy ground using the reflection-coefficient approximation

    NARCIS (Netherlands)

    Fernández Pantoja, M.; Yarovoy, A.G.; Rubio Bretones, A.; González García, S.

    2009-01-01

    This paper presents a procedure to extend the methods of moments in time domain for the transient analysis of thin-wire antennas to include those cases where the antennas are located over a lossy half-space. This extended technique is based on the reflection coefficient (RC) approach, which approxim

  20. Microstructure and Mechanical Properties of Ti-6Al-4V Fabricated by Vertical Wire Feeding with Axisymmetric Multi-Laser Source

    Directory of Open Access Journals (Sweden)

    Jie Fu

    2017-02-01

    Full Text Available Vertical wire feeding with an axisymmetric multi-laser source (feeding the wire vertically into the molten pool has exhibited great advantages over LAM (laser additive manufacturing with paraxial wire feeding, which has an anisotropic forming problem in different scanning directions. This paper investigates the forming ability of vertical wire feeding with an axisymmetric multi-laser source, and the microstructure and mechanical properties of the fabricated components. It has been found that vertical wire feeding with an axisymmetric multi-laser source has a strong forming ability with no anisotropic forming problem when fabricating the complex parts in a three-axis machine tool. Most of the grains in the samples are equiaxed grains, and a small amount of short columnar grains exist which are parallel to each other. The microstructure of the fabricated samples exhibits a fine basket-weave structure and martensite due to the fast cooling rate which was caused by the small size of the molten pool and the additional heat dissipation from the feeding wire. The static tensile test shows that the average ultimate tensile strength is 1140 MPa in the scanning direction and 1115 MPa in the building direction, and the average elongation is about 6% in both directions.

  1. FDTD simulation of LEMP propagation over lossy ground: Influence of distance, ground conductivity, and source parameters

    Science.gov (United States)

    Aoki, Masanori; Baba, Yoshihiro; Rakov, Vladimir A.

    2015-08-01

    We have computed lightning electromagnetic pulses (LEMPs), including the azimuthal magnetic field Hφ, vertical electric field Ez, and horizontal (radial) electric field Eh that propagated over 5 to 200 km of flat lossy ground, using the finite difference time domain (FDTD) method in the 2-D cylindrical coordinate system. This is the first systematic full-wave study of LEMP propagation effects based on a realistic return-stroke model and including the complete return-stroke frequency range. Influences of the return-stroke wavefront speed (ranging from c/2 to c, where c is the speed of light), current risetime (ranging from 0.5 to 5 µs), and ground conductivity (ranging from 0.1 mS/m to ∞) on Hφ, Ez, and Eh have been investigated. Also, the FDTD-computed waveforms of Eh have been compared with the corresponding ones computed using the Cooray-Rubinstein formula. Peaks of Hφ, Ez, and Eh are nearly proportional to the return-stroke wavefront speed. The peak of Eh decreases with increasing current risetime, while those of Hφ and Ez are only slightly influenced by it. The peaks of Hφ and Ez are essentially independent of the ground conductivity at a distance of 5 km. Beyond this distance, they appreciably decrease relative to the perfectly conducting ground case, and the decrease is stronger for lower ground conductivity values. The peak of Eh increases with decreasing ground conductivity. The computed Eh/Ez is consistent with measurements of Thomson et al. (1988). The observed decrease of Ez peak and increase of Ez risetime due to propagation over 200 km of Florida soil are reasonably well reproduced by the FDTD simulation with ground conductivity of 1 mS/m.

  2. Energy well. Ground-source heat in one-family houses; Energiakaivo. Maalaemmoen hyoedyntaeminen pientaloissa

    Energy Technology Data Exchange (ETDEWEB)

    Juvonen, J.; Lapinlampi, T.

    2013-08-15

    This guide deals with the legislation, planning, building, usage and maintenance of ground-source heat systems. The guide gives recommendations and instructions on national level on the permit practices and how to carry out the whole ground-source heat system project. The main focus of the guide is on energy wells for one-family houses. The principle is that an action permit is needed to build a ground-source heat system. On ground water areas a permit according to the water act may also be required. To avoid any problems, the placement of the system needs to be planned precisely. This guide gives a comprehension to the orderer on the issues that need to be considered before ordering, during construction, when the system is running and when giving up the use of the ground-source heat system. (orig.)

  3. Ground Source Heat Pump in Heating System with Electronics Monitoring

    Directory of Open Access Journals (Sweden)

    NEAMŢU Ovidiu

    2013-10-01

    Full Text Available The monitoring system is implemented for a ground coupled heat pump in heating/ system. The borehole heat exchangers – which are 150 m long - are filled with a mixture of water and ethilene glycol calledbrine. Metering and monitoring energy consumption is achieved for: heat pump, circulation pumps, additional electrical heating, hot air ventilation systems, control systems with sensors: analog and smart sensors. Instantaneous values are stored in a local computer.

  4. Federal Technology Alert: Ground-Source Heat Pumps Applied to Federal Facilities--Second Edition

    Energy Technology Data Exchange (ETDEWEB)

    Hadley, Donald L.

    2001-03-01

    This Federal Technology Alert, which was sponsored by the U.S. Department of Energy's Office of Federal Energy Management Programs, provides the detailed information and procedures that a Federal energy manager needs to evaluate most ground-source heat pump applications. This report updates an earlier report on ground-source heat pumps that was published in September 1995. In the current report, general benefits of this technology to the Federal sector are described, as are ground-source heat pump operation, system types, design variations, energy savings, and other benefits. In addition, information on current manufacturers, technology users, and references for further reading are provided.

  5. Thevenin source resistances of the touch, transferred and step voltages of a grounding system

    Energy Technology Data Exchange (ETDEWEB)

    Chow, Y.L.; Salama, M.M.A.; Djogo, G. [University of Waterloo, ON (Canada)

    1999-03-01

    The source resistances for surface voltages (touch, transferred and step voltage) are considered. It is proved that the source resistances of the touch and transferred voltages are the same, given by the grounding resistances between the feet of a human and the grounding system. In a practical situation, however, this resistance is very close to that of the ANSI/IEEE Standard 80 that is widely accepted. The source resistance of the step voltage is simply the resistance between the two feet, not at all perturbed by the grounding system. Proofs are derived rigorously by combining the field Galerkin's moment method and basic circuit theory. (author)

  6. Using Ground Source Heat Pumps for Renewable Energy

    OpenAIRE

    Xhevat BERISHA

    2017-01-01

    This paper provides background information on the current energy supply, energy demand, and energy sources in Kosovo. Moreover, it presents the country‟s current level of applying alternative energy sources. Additionally, this paper focuses on geothermal energy as a renewable energy resource with the potential to contribute to a sustainable use of resources to meet renewable energy and energy efficiency requirements of the European Union (EU), “EU 20 20 by 2020” policy. Hence, a careful analy...

  7. HVDC Ground Electrodes - a Source of Geophysical Data

    Science.gov (United States)

    Freire, P. F.; Pereira, S. Y.

    2015-12-01

    The HVDC electrode is a component of a High Voltage Direct Current energy transmission system, and is designed to inject into the ground continuous currents up to 3500 A. The typical HVDC ground electrode is a ring of vertical conductors, 1 km wide, buried a few tens of meters.The design of a HVDC electrode is based on extensive geological, geotechnical and geophysical surveys. Geophysical data are usually electrical (VES) and electromagnetic (TEM/MT) acquisitions, for the modeling of the shallow, near-surface and deep layers of the crust. This survey aims, first, the electrode site selection, and then, at the selected site, this data is combined into a single apparent resistivity curve, which is inverted, allowing for the determination of the layered geoelectric crust model. The injection of electrical continuous current in the electrode is then simulated, with the geoelectric crust model, for the determination of the soil surface potential profile (which is usually asymmetric for different directions, due to non-1D geoelectric models).For the commissioning of a HVDC electrode, field measurements are done, such as electrode grounding resistance, soil surface potentials and metal-to-soil potentials at specific structures (buried pipelines, for instance).The geophysical data acquired during the design phase is a set of data completely independent from the electrical data acquired during the electrode commissioning phase, and both are correlated by the geoelectric model. It happens, therefore, that the geoelectric model can be calibrated based on the electrical data, with the correction of static shifts and other adjustments.This paper suggests that the commissioning of HVDC systems should be associated to a research & development program, with a university or foundation. The idea is to enjoy the opportunity of a more complete field survey, with the acquisition of a wide set of data for a better geological characterization of the area where the electrode was built.

  8. Modelling the Impact of Ground Planes on Antenna Radiation Using the Method of Auxiliary Sources

    DEFF Research Database (Denmark)

    Larsen, Niels Vesterdal; Breinbjerg, Olav

    2007-01-01

    The Method of Auxiliary Sources is employed to model the impact of finite ground planes on the radiation from antennas. In many cases the computational cost of available commercial tools restricts the simulations to include only a small ground plane or, by use of the image principle, the infinitely...

  9. 微机防误装置地线管理器应用研究%Research on application of the PC manager for the ground wire management of the anti - misoperation device

    Institute of Scientific and Technical Information of China (English)

    吴玉柱

    2011-01-01

    对五防地线管理器进行研究,探讨合理利用闭锁逻辑及锁具加强地线日常管理,从源头上有效杜绝接地线误操作。%Through the research of the "5 - anti" ground wire manager, this article discusses how to improve the ground wire daily management via the blocking logic and locker, and prevent the mis -operations effectively.

  10. A Method of Auxiliary Sources Approach for Modelling the Impact of Ground Planes on Antenna

    DEFF Research Database (Denmark)

    Larsen, Niels Vesterdal; Breinbjerg, Olav

    2006-01-01

    The Method of Auxiliary Sources (MAS) is employed to model the impact of finite ground planes on the radiation from antennas. Two different antenna test cases are shown and the calculated results agree well with reference measurements......The Method of Auxiliary Sources (MAS) is employed to model the impact of finite ground planes on the radiation from antennas. Two different antenna test cases are shown and the calculated results agree well with reference measurements...

  11. Pulsed-source time-resolved phosphorimetry: comparison of a commercial gated photomultiplier with a specially wired ungated photomultiplier.

    Science.gov (United States)

    Persvik, Øyvind; Melø, Thor Bernt; Naqvi, K Razi

    2013-06-01

    A common problem encountered in recording delayed light emission is that the signal of interest is preceded by a much more intense signal arising from prompt fluorescence. When a photomultiplier tube (PMT) is used as the photosensor in a pulsed-source phosphorimeter, two options are open to an experimenter who finds mechanical shutters inconvenient or impracticable and photon counting inappropriate: apply an electronic gate that suppresses the PMT gain for a brief period, or use a wiring scheme that enables the PMT to quickly regain normal operation after an intense burst of prompt emission. The performance of a squirrel-cage PMT that operates in the latter mode is compared with a new gateable PMT (Hamamatsu H11526 series) with a minimum gate time of 100 ns. The two detectors are found to provide practically the same temporal record of the delayed emission, but the ungated PMT is slightly superior in terms of recovery time and signal-to-noise ratio.

  12. Radiation sources with planar wire arrays and planar foils for inertial confinement fusion and high energy density physics research

    Energy Technology Data Exchange (ETDEWEB)

    Kantsyrev, V. L.; Safronova, A. S.; Esaulov, A. A.; Shrestha, I.; Astanovitsky, A.; Osborne, G. C.; Shlyaptseva, V. V.; Weller, M. E.; Keim, S.; Stafford, A.; Cooper, M. [Department of Physics, University of Nevada, Reno, Nevada 89557 (United States); Chuvatin, A. S. [Laboratorie de Physique des Plasmas, Ecole Polytechnique, 91128 Palaiseau (France); Rudakov, L. I. [Icarus Research Inc., Bethesda, Maryland 20824 (United States); Velikovich, A. L. [Plasma Physics Division, Naval Research Laboratory, Washington, DC 20375 (United States)

    2014-03-15

    This article reports on the joint success of two independent lines of research, each of them being a multi-year international effort. One of these is the development of innovative sources, such as planar wire arrays (PWAs). PWAs turned out to be a prolific radiator, which act mainly as a resistor, even though the physical mechanism of efficient magnetic energy conversion into radiation still remains unclear. We review the results of our extensive studies of PWAs. We also report the new results of the experimental comparison PWAs with planar foil liners (another promising alternative to wire array loads at multi-mega-ampere generators). Pioneered at UNR, the PWA Z-pinch loads have later been tested at the Sandia National Laboratories (SNL) on the Saturn generator, on GIT-12 machine in Russia, and on the QiangGuang-1 generator in China, always successfully. Another of these is the drastic improvement in energy efficiency of pulsed-power systems, which started in early 1980s with Zucker's experiments at Naval Research Laboratory (NRL). Successful continuation of this approach was the Load Current Multiplier (LCM) proposed by Chuvatin in collaboration with Rudakov and Weber from NRL. The 100 ns LCM was integrated into the Zebra generator, which almost doubled the plasma load current, from 0.9 to 1.7 MA. The two above-mentioned innovative approaches were used in combination to produce a new compact hohlraum radiation source for ICF, as jointly proposed by SNL and UNR [Jones et al., Phys. Rev. Lett. 104, 125001 (2010)]. The first successful proof-of-the-principle experimental implementation of new hohlraum concept at university-scale generator Zebra/LCM is demonstrated. A numerical simulation capability with VisRaD code (from PRISM Co.) established at UNR allowed for the study of hohlraum coupling physics and provides the possibility of optimization of a new hohlraum. Future studies are discussed.

  13. Radiation sources with planar wire arrays and planar foils for inertial confinement fusion and high energy density physics research

    Science.gov (United States)

    Kantsyrev, V. L.; Chuvatin, A. S.; Safronova, A. S.; Rudakov, L. I.; Esaulov, A. A.; Velikovich, A. L.; Shrestha, I.; Astanovitsky, A.; Osborne, G. C.; Shlyaptseva, V. V.; Weller, M. E.; Keim, S.; Stafford, A.; Cooper, M.

    2014-03-01

    This article reports on the joint success of two independent lines of research, each of them being a multi-year international effort. One of these is the development of innovative sources, such as planar wire arrays (PWAs). PWAs turned out to be a prolific radiator, which act mainly as a resistor, even though the physical mechanism of efficient magnetic energy conversion into radiation still remains unclear. We review the results of our extensive studies of PWAs. We also report the new results of the experimental comparison PWAs with planar foil liners (another promising alternative to wire array loads at multi-mega-ampere generators). Pioneered at UNR, the PWA Z-pinch loads have later been tested at the Sandia National Laboratories (SNL) on the Saturn generator, on GIT-12 machine in Russia, and on the QiangGuang-1 generator in China, always successfully. Another of these is the drastic improvement in energy efficiency of pulsed-power systems, which started in early 1980s with Zucker's experiments at Naval Research Laboratory (NRL). Successful continuation of this approach was the Load Current Multiplier (LCM) proposed by Chuvatin in collaboration with Rudakov and Weber from NRL. The 100 ns LCM was integrated into the Zebra generator, which almost doubled the plasma load current, from 0.9 to 1.7 MA. The two above-mentioned innovative approaches were used in combination to produce a new compact hohlraum radiation source for ICF, as jointly proposed by SNL and UNR [Jones et al., Phys. Rev. Lett. 104, 125001 (2010)]. The first successful proof-of-the-principle experimental implementation of new hohlraum concept at university-scale generator Zebra/LCM is demonstrated. A numerical simulation capability with VisRaD code (from PRISM Co.) established at UNR allowed for the study of hohlraum coupling physics and provides the possibility of optimization of a new hohlraum. Future studies are discussed.

  14. Using Ground Source Heat Pumps for Renewable Energy

    Directory of Open Access Journals (Sweden)

    Xhevat BERISHA

    2017-04-01

    Full Text Available This paper provides background information on the current energy supply, energy demand, and energy sources in Kosovo. Moreover, it presents the country‟s current level of applying alternative energy sources. Additionally, this paper focuses on geothermal energy as a renewable energy resource with the potential to contribute to a sustainable use of resources to meet renewable energy and energy efficiency requirements of the European Union (EU, “EU 20 20 by 2020” policy. Hence, a careful analysis is included on how to approach the aforementioned targets through investments in geothermal energy through providing an energy consumption forecast and analysing geothermal energy projects in Europe and specifically in Kosovo. This paper carefully represents the potential usage of geothermal energy in Kosovo, renewable energy source targets, and it addresses the importance of laws, regulations, and reports regarding the utilization of this type of energy. Economic and environmental implications of investing in geothermal energy - geothermal heat pumps for the case of International Village are additionally analysed. Lastly, recommendations and conclusions, for future actions, are derived and addressed to relevant stakeholders, primarily policy-makers, and government representatives.

  15. Ground Source Heat Pump Sub-Slab Heat Exchange Loop Performance in a Cold Climate

    Energy Technology Data Exchange (ETDEWEB)

    Mittereder, Nick [IBACOS, Inc., Pittsburgh, PA (United States); Poerschke, Andrew [IBACOS, Inc., Pittsburgh, PA (United States)

    2013-11-01

    This report presents a cold-climate project that examines an alternative approach to ground source heat pump (GSHP) ground loop design. The innovative ground loop design is an attempt to reduce the installed cost of the ground loop heat exchange portion of the system by containing the entire ground loop within the excavated location beneath the basement slab. Prior to the installation and operation of the sub-slab heat exchanger, energy modeling using TRNSYS software and concurrent design efforts were performed to determine the size and orientation of the system. One key parameter in the design is the installation of the GSHP in a low-load home, which considerably reduces the needed capacity of the ground loop heat exchanger. This report analyzes data from two cooling seasons and one heating season.

  16. Mixed Waste Management Facility (MWMF) Old Burial Ground (OBG) source control technology and inventory study

    Energy Technology Data Exchange (ETDEWEB)

    Flach, G.P.; Rehder, T.E.; Kanzleiter, J.P.

    1996-10-02

    This report has been developed to support information needs for wastes buried in the Burial Ground Complex. Information discussed is presented in a total of four individual attachments. The general focus of this report is to collect information on estimated source inventories, leaching studies, source control technologies, and to provide information on modeling parameters and associated data deficiencies.

  17. Ground-water temperature of the Wyoming quadrangle in central Delaware : with application to ground-water-source heat pumps

    Science.gov (United States)

    Hodges, Arthur L.

    1982-01-01

    Ground-water temperature was measured during a one-year period (1980-81) in 20 wells in the Wyoming Quadrangle in central Delaware. Data from thermistors set at fixed depths in two wells were collected twice each week, and vertical temperature profiles of the remaining 18 wells were made monthly. Ground-water temperature at 8 feet below land surface in well Jc55-1 ranged from 45.0 degrees F in February to 70.1 degrees F in September. Temperature at 35 feet below land surface in the same well reached a minimum of 56.0 degrees F in August, and a maximum of 57.8 degrees F in February. Average annual temperature of ground water at 25 feet below land surface in all wells ranged from 54.6 degrees F to 57.8 degrees F. Variations of average temperature probably reflect the presence or absence of forestation in the recharge areas of the wells. Ground-water-source heat pumps supplied with water from wells 30 or more feet below land surface will operate more efficiently in both heating and cooling modes than those supplied with water from shallower depths. (USGS)

  18. IMPACT OF GEOTHERMAL GRADIENT ON GROUND SOURCE HEAT PUMP SYSTEM MODELING

    Directory of Open Access Journals (Sweden)

    Tomislav Kurevija

    2014-07-01

    Full Text Available ndisturbed ground temperature is one of the most crucial thermogeological parameters needed for shallow geothermal resources assessment. Energy considered to be geothermal is energy stored in the ground at depths where solar radiation has no effect. At depth where undisturbed ground temperature occurs there is no influence of seasonal variations in air temperature from surface. Exact temperature value, and depth where it occurs, is functionally dependent on surface climate parameters and thermogeologic properties of ground. After abovementioned depth, increase of ground temperature is solely dependent on geothermal gradient. Accurately determined value of undisturbed ground temperature is beneficial for proper sizing of borehole heat exchangers. On practical example of building which is being heated and cooled with shallow geothermal resource, influences of undisturbed ground temperature and geothermal gradient, on size of borehole heat exchanger are going to be presented. Sizing of borehole heat exchanger was calculated with commercial software Ground Loop Designer (GLD, which uses modified line source and cylinder source solutions of heat conduction in solids.

  19. High-efficiency single-photon source: The photonic wire geometry

    DEFF Research Database (Denmark)

    Claudon, J.; Bazin, Maela; Malik, Nitin S.

    2009-01-01

    We present a single-photon-source design based on the emission of a quantum dot embedded in a semiconductor (GaAs) nanowire. The nanowire ends are engineered (efficient metallic mirror and tip taper) to reach a predicted record-high collection efficiency of 90% with a realistic design. Preliminary...

  20. Numerical analysis of heat exchange processes for the ground source heat pump system

    Science.gov (United States)

    Saito, H.; Muto, H.; Moritani, S.; Kohgo, Y.; Hamamoto, S.; Takemura, T.; Ohnishi, J.; Komatsu, T.

    2012-12-01

    Ground source heat pump systems (GSHP) use ground or groundwater as a heat source. They can achieve much higher coefficient of performance (COP) than conventional air source heat pump systems because the temperature of the ground is much more stable than that of the air. Heat energy in the ground is then viewed as one of the renewable energy sources. GSHP has been receiving great interests among countries in North America and Western Europe, as well as some developed countries in Asia because it can potentially reduce energy consumption and greenhouse gas emission. While GSHP can inject heat from the buildings to the ground for cooling during the summer, it can pump heat stored in the ground for heating during the winter. As some physical, chemical, and biological properties of the ground and groundwater are temperature dependent, running GSHP can eventually affect groundwater quality. The main objective of this project was to develop a model that allows predicting not only ground and groundwater temperatures but also changes in physical, chemical, and biological properties of ground and groundwater with GSHP under operations. This particular study aims at simulating heat exchange and transfer processes in the ground for a vertical-loop closed GSHP system. In the closed GSHP system, an anti-freezing solution is circulated inside the closed-loop tube, called U-tube, that is buried in the ground. Heat is then transferred to the anti-freezing solution in the U-tube by a heat exchanger. In this study we used HYDRUS to predict temperature of the anti-freezing solution, as well as that of the ground. HYDRUS allows one to simulate variably-saturated water flow and solute and heat transport in porous media numerically in two- and three-dimensional domains with great flexibility in defining boundary conditions. At first changes in anti-freezing solution temperatures measured were predicted in response to Thermal Response Test (TRT) conducted at our study site. Then, heat

  1. Ground source thermo-pumps for individual residential houses; Les thermopompes a capteur enterres dans les residences individuelles

    Energy Technology Data Exchange (ETDEWEB)

    Ossant, G. [Societe Syrec (France)

    1997-12-31

    The main principles, performances and constraints of the various types of ground source thermo-pumps for individual houses, i.e. ground/ground thermo-pumps, glycol water/water thermo-pumps and ground/water thermo-pumps are reviewed, and their energy consumptions are discussed. The design and operating conditions of a reverse ground source thermo-pump (Syrec) for space heating and air conditioning through a hot and cold floor system and a Syrec ground source thermo-pump for water heating, are presented

  2. SENSITIVITY OF STRUCTURAL RESPONSE TO GROUND MOTION SOURCE AND SITE PARAMETERS.

    Science.gov (United States)

    Safak, Erdal; Brebbia, C.A.; Cakmak, A.S.; Abdel Ghaffar, A.M.

    1985-01-01

    Designing structures to withstand earthquakes requires an accurate estimation of the expected ground motion. While engineers use the peak ground acceleration (PGA) to model the strong ground motion, seismologists use physical characteristics of the source and the rupture mechanism, such as fault length, stress drop, shear wave velocity, seismic moment, distance, and attenuation. This study presents a method for calculating response spectra from seismological models using random vibration theory. It then investigates the effect of various source and site parameters on peak response. Calculations are based on a nonstationary stochastic ground motion model, which can incorporate all the parameters both in frequency and time domains. The estimation of the peak response accounts for the effects of the non-stationarity, bandwidth and peak correlations of the response.

  3. Covering of heating load of object by using ground heat as a renewable energy source

    Directory of Open Access Journals (Sweden)

    Čenejac Aleksandra R.

    2012-01-01

    Full Text Available Rational use of energy, improving energy performance of buildings and use of renewable energy sources are the most important measures for reducing consumption of non-renewable primary energy (solid, liquid, and gaseous fuels, environmental protection and for the future sustainable development of mankind. In the total primary energy consumption great part is related to building industry, for heating spaces in which people stay and live. Renewable energy sources (RES present natural resources and they are one of the alternatives that allow obtaining heat for heating buildings, and by that they provide a significant contribution to the energy balance of a country. This paper analyzes the participation of ground source as RES, when the vertical (the probe in the ground and horizontal (registry in the ground heat exchangers are used for covering heating load of the building.

  4. Non-Stationary Modelling and Simulation of Near-Source Earthquake Ground Motion

    DEFF Research Database (Denmark)

    Skjærbæk, P. S.; Kirkegaard, Poul Henning; Fouskitakis, G. N.

    This paper is concerned with modelling and simulation of near-source earthquake ground motion. Recent studies have revealed that these motions show heavy non-stationary behaviour with very low frequencies dominating parts of the earthquake sequence. Modelling and simulation of this behaviour...... by an epicentral distance of 16 km and measured during the 1979 Imperial valley earthquake in California (USA). The results of the study indicate that while all three approaches can succesfully predict near-source ground motions, the Neural Network based one gives somewhat poorer simulation results....

  5. Non-Stationary Modelling and Simulation of Near-Source Earthquake Ground Motion

    DEFF Research Database (Denmark)

    Skjærbæk, P. S.; Kirkegaard, Poul Henning; Fouskitakis, G. N.

    1997-01-01

    This paper is concerned with modelling and simulation of near-source earthquake ground motion. Recent studies have revealed that these motions show heavy non-stationary behaviour with very low frequencies dominating parts of the earthquake sequence. Modeling and simulation of this behaviour...... by an epicentral distance of 16 km and measured during the 1979 Imperial Valley earthquake in California (U .S .A.). The results of the study indicate that while all three approaches can successfully predict near-source ground motions, the Neural Network based one gives somewhat poorer simulation results....

  6. 基于地线改造的巡检机器人机械结构设计%Mechanism design of an inspection robot for reformed ground wire

    Institute of Scientific and Technical Information of China (English)

    徐显金; 吴功平; 何缘; 刘明; 曹琪; 徐青山; 李胜邦

    2011-01-01

    In order to improve the inspection efficiency,it proposes a reformation scheme to make the overhead ground wire structure and an inspection robot as a whole system, namely, reform the dampers,suspension clamps, and the top of tension tower into an unobstructed moving path.Thus the robot based on the reformed structure is able to roll across obstacles to carry out the inspection mission along the whole path effectively.Then the key technologies ,I.e.reformating ground wire structure and robot body's mechanism are emphasized.Last the. Field tests of an industrial prototype under typical working conditions are performed to prove the validity of the proposed inspection robot system and its broad application prospects.%针对目前研究的巡检机器人巡检效率低的问题,提出一种将巡检机器人和架空地线结构作为一个整体系统的研究方法,即将架空地线上的阻挡型防震锤、悬垂线夹和耐张塔头等阻挡型结构改造为无阻挡型道路结构,使得巡检机器人只需穿越这些越障碍物而无需跨越障碍物,从而大大提高机器人巡检效率.在此基础上,提出了一种沿架空地线行驶的自主巡检机器人系统,并着重阐述了线路改造和移动机器人机构两大关键技术.通过现场典型作业环境的运行试验,表明了提出的自主巡检机器人系统的正确性和良好的应用前景.

  7. 30 CFR 56.12053 - Circuits powered from trolley wires.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Circuits powered from trolley wires. 56.12053... § 56.12053 Circuits powered from trolley wires. Ground wires for lighting circuits powered from trolley wires shall be connected securely to the ground-return circuit....

  8. 30 CFR 57.12053 - Circuits powered from trolley wires.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Circuits powered from trolley wires. 57.12053... Electricity Surface and Underground § 57.12053 Circuits powered from trolley wires. Ground wires for lighting circuits powered from trolley wires shall be connected securely to the ground return circuit. Surface Only...

  9. Heating performance of a ground source heat pump system installed in a school building

    Institute of Scientific and Technical Information of China (English)

    Jaedo; SONG; Kwangho; LEE; Youngman; JEONG; Seongir; CHEONG; Jaekeun; LEE; Yujin; HWANG; Yeongho; LEE; Donghyuk; LEE

    2010-01-01

    The heating performance of a water-to-refrigerant type ground source heat pump system is represented in this paper under the actual working conditions of the GSHP(ground source heat pump) system during the winter season of 2008.Ten heat pump equipments with the capacity of 10 HP each and a closed vertical typed-ground heat exchanger with 24 boreholes of 175 m in depth were constructed.We investigated a variety of working conditions,including the outdoor temperature,the ground temperature,and the water temperature of inlet and outlet of the ground heat exchanger in order to examine the heating performance of the GSHP system.Subsequently,the heating capacity and the input power were investigated to determine the heating performance of the GSHP system.The average heating coefficient of performance(COP) of the heat pump was noted to be 5.1 at partial load of 47%,while the overall system COP was found to be 4.2.Also,performance of the GSHP system was compared with that of air source heat pump.

  10. Earthquake ground-motion in presence of source and medium heterogeneities

    KAUST Repository

    Vyas, Jagdish Chandra

    2017-01-01

    This dissertation work investigates the effects of earthquake rupture complexity and heterogeneities in Earth structure on near-field ground-motions. More specifically, we address two key issues in seismology: (1) near-field ground-shaking variability as function of distance and azimuth for unilateral directive ruptures, and (2) impact of rupture complexity and seismic scattering on Mach wave coherence associated with supershear rupture propagation. We examine earthquake ground-motion variability associated with unilateral ruptures based on ground-motion simulations of the MW 7.3 1992 Landers earthquake, eight simplified source models, and a MW 7.8 rupture simulation (ShakeOut) for the San Andreas fault. Our numerical modeling reveals that the ground-shaking variability in near-fault distances (< 20 km) is larger than that given by empirical ground motion prediction equations. In addition, the variability decreases with increasing distance from the source, exhibiting a power-law decay. The high near-field variability can be explained by strong directivity effects whose influence weaken as we move away from the fault. At the same time, the slope of the power-law decay is found to be dominantly controlled by slip heterogeneity. Furthermore, the ground-shaking variability is high in the rupture propagation direction whereas low in the directions perpendicular to it. However, the variability expressed as a function of azimuth is not only sensitive to slip heterogeneity, but also to rupture velocity. To study Mach wave coherence for supershear ruptures, we consider heterogeneities in rupture parameters (variations in slip, rise time and rupture speed) and 3D scattering media having small-scale random heterogeneities. The Mach wave coherence is reduced at near-fault distances (< 10 km) by the source heterogeneities. At the larger distances from the source, medium scattering plays the dominant role in reducing the Mach wave coherence. Combined effect of the source and

  11. Ground Truth Events with Source Geometry in Eurasia and the Middle East

    Science.gov (United States)

    2016-06-02

    in Saudi Arabia, 5 in Ethiopia, and 10 in Tanzania with magnitudes of 3 or greater. Source parameters were obtained through moment tensor inversions...TERMS seismic location; seismic ground truth; seismic moment tensor 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18. NUMBER OF PAGES...Arabia ..................... 4 Figure 2. Results from the grid search and moment tensor inversion for source mechanisms for events in Saudi Arabia

  12. Ground Source Heat Pump Sub-Slab Heat Exchange Loop Performance in a Cold Climate

    Energy Technology Data Exchange (ETDEWEB)

    Mittereder, N.; Poerschke, A.

    2013-11-01

    This report presents a cold-climate project that examines an alternative approach to ground source heat pump (GSHP) ground loop design. The innovative ground loop design is an attempt to reduce the installed cost of the ground loop heat exchange portion of the system by containing the entire ground loop within the excavated location beneath the basement slab. Prior to the installation and operation of the sub-slab heat exchanger, energy modeling using TRNSYS software and concurrent design efforts were performed to determine the size and orientation of the system. One key parameter in the design is the installation of the GSHP in a low-load home, which considerably reduces the needed capacity of the ground loop heat exchanger. This report analyzes data from two cooling seasons and one heating season. Upon completion of the monitoring phase, measurements revealed that the initial TRNSYS simulated horizontal sub-slab ground loop heat exchanger fluid temperatures and heat transfer rates differed from the measured values. To determine the cause of this discrepancy, an updated model was developed utilizing a new TRNSYS subroutine for simulating sub-slab heat exchangers. Measurements of fluid temperature, soil temperature, and heat transfer were used to validate the updated model.

  13. Dynamic corner frequency in source spectral model for stochastic synthesis of ground motion

    Institute of Scientific and Technical Information of China (English)

    Xiaodan Sun; Xiaxin Tao; Guoxin Wang; Taojun Liu

    2009-01-01

    The static corner frequency and dynamic corner frequency in stochastic synthesis of ground motion from finite-fault modeling are introduced, and conceptual disadvantages of the two are discussed in this paper. Furthermore, the non-uniform radiation of seismic wave on the fault plane, as well as the trend of the larger rupture area, the lower corner frequency, can be described by the source spectral model developed by the authors. A new dynamic corner frequency can be developed directly from the model. The dependence of ground motion on the size of subfault can be eliminated if this source spectral model is adopted in the synthesis. Finally, the approach presented is validated from the comparison between the synthesized and observed ground motions at six rock stations during the Northridge earthquake in 1994.

  14. Strong ground-motion prediction from Stochastic-dynamic source models

    Science.gov (United States)

    Guatteri, Mariagiovanna; Mai, P.M.; Beroza, G.C.; Boatwright, J.

    2003-01-01

    In the absence of sufficient data in the very near source, predictions of the intensity and variability of ground motions from future large earthquakes depend strongly on our ability to develop realistic models of the earthquake source. In this article we simulate near-fault strong ground motion using dynamic source models. We use a boundary integral method to simulate dynamic rupture of earthquakes by specifying dynamic source parameters (fracture energy and stress drop) as spatial random fields. We choose these quantities such that they are consistent with the statistical properties of slip heterogeneity found in finite-source models of past earthquakes. From these rupture models we compute theoretical strong-motion seismograms up to a frequency of 2 Hz for several realizations of a scenario strike-slip Mw 7.0 earthquake and compare empirical response spectra, spectra obtained from our dynamic models, and spectra determined from corresponding kinematic simulations. We find that spatial and temporal variations in slip, slip rise time, and rupture propagation consistent with dynamic rupture models exert a strong influence on near-source ground motion. Our results lead to a feasible approach to specify the variability in the rupture time distribution in kinematic models through a generalization of Andrews' (1976) result relating rupture speed to apparent fracture energy, stress drop, and crack length to 3D dynamic models. This suggests that a simplified representation of dynamic rupture may be obtained to approximate the effects of dynamic rupture without having to do full dynamic simulations.

  15. Ground heat flux and power sources of low-enthalpy geothermal systems

    Science.gov (United States)

    Bayer, Peter; Blum, Philipp; Rivera, Jaime A.

    2015-04-01

    Geothermal heat pumps commonly extract energy from the shallow ground at depths as low as approximately 400 m. Vertical borehole heat exchangers are often applied, which are seasonally operated for decades. During this lifetime, thermal anomalies are induced in the ground and surface-near aquifers, which often grow over the years and which alleviate the overall performance of the geothermal system. As basis for prediction and control of the evolving energy imbalance in the ground, focus is typically set on the ground temperatures. This is reflected in regulative temperature thresholds, and in temperature trends, which serve as indicators for renewability and sustainability. In our work, we examine the fundamental heat flux and power sources, as well as their temporal and spatial variability during geothermal heat pump operation. The underlying rationale is that for control of ground temperature evolution, knowledge of the primary heat sources is fundamental. This insight is also important to judge the validity of simplified modelling frameworks. For instance, we reveal that vertical heat flux from the surface dominates the basal heat flux towards a borehole. Both fluxes need to be accounted for as proper vertical boundary conditions in the model. Additionally, the role of horizontal groundwater advection is inspected. Moreover, by adopting the ground energy deficit and long-term replenishment as criteria for system sustainability, an uncommon perspective is adopted that is based on the primary parameter rather than induced local temperatures. In our synthetic study and dimensionless analysis, we demonstrate that time of ground energy recovery after system shutdown may be longer than what is expected from local temperature trends. In contrast, unrealistically long recovery periods and extreme thermal anomalies are predicted without account for vertical ground heat fluxes and only when the energy content of the geothermal reservoir is considered.

  16. Technology Solutions Case Study: Ground Source Heat Pump Research, TaC Studios Residence, Atlanta, Georigia

    Energy Technology Data Exchange (ETDEWEB)

    None

    2014-09-01

    This case study describes the construction of a new test home that demonstrates current best practices for the mixed-humid climate, including a high performance ground source heat pump for heating and cooling, a building envelope featuring advanced air sealing details and low-density spray foam insulation, and glazing that exceeds ENERGY STAR requirements.

  17. Upper and lower bounds of ground-motion variabilities: implication for source properties

    Science.gov (United States)

    Cotton, Fabrice; Reddy-Kotha, Sreeram; Bora, Sanjay; Bindi, Dino

    2017-04-01

    One of the key challenges of seismology is to be able to analyse the physical factors that control earthquakes and ground-motion variabilities. Such analysis is particularly important to calibrate physics-based simulations and seismic hazard estimations at high frequencies. Within the framework of the development of ground-motion prediction equation (GMPE) developments, ground-motions residuals (differences between recorded ground motions and the values predicted by a GMPE) are computed. The exponential growth of seismological near-source records and modern GMPE analysis technics allow to partition these residuals into between- and a within-event components. In particular, the between-event term quantifies all those repeatable source effects (e.g. related to stress-drop or kappa-source variability) which have not been accounted by the magnitude-dependent term of the model. In this presentation, we first discuss the between-event variabilities computed both in the Fourier and Response Spectra domains, using recent high-quality global accelerometric datasets (e.g. NGA-west2, Resorce, Kiknet). These analysis lead to the assessment of upper bounds for the ground-motion variability. Then, we compare these upper bounds with lower bounds estimated by analysing seismic sequences which occurred on specific fault systems (e.g., located in Central Italy or in Japan). We show that the lower bounds of between-event variabilities are surprisingly large which indicates a large variability of earthquake dynamic properties even within the same fault system. Finally, these upper and lower bounds of ground-shaking variability are discussed in term of variability of earthquake physical properties (e.g., stress-drop and kappa_source).

  18. Site dependence of far-source ground motions during the Wenchuan earthquake

    Institute of Scientific and Technical Information of China (English)

    Longjun Xu; Haiying Yu; Wenhai Cao; Lili Xie

    2009-01-01

    This paper aimed to examine the site dependence and evaluate the methods for site analysis of far-source ground motions. This was achieved through the examination of frequency content estimated by different methods based on strong ground motions recorded at twelve far-source stations in Shandong province during the Wenchuan earthquake. The stations were located in sites with soil profiles ranging from code classes 1 to III. Approaches used included the Fourier amplitude spectrum (FAS), the earthquake response spectrum (ERS), the spectral ratio between the horizontal and the vertical components (H/V), the spectral ratio between the spectra at the site and at a reference site (SRRS), and coda wave analysis (CWA). Results showed that major periods of these ground motions obtained by FAS, ERS and H/V ratio methods were all evidently larger than site dominant periods; the periods were also different from each other and mainly reflected the frequency content of long period components. Prominent periods obtained by the SRRS approach neither illuminated the long period aspect nor efficiently determined site features of the motions. The CWA resulted in a period close to site period for stations with good quality recordings. The results obtained in this study will be useful for the evaluation of far-source effect in constructing seismic design spectra and in selecting methods for ground motion site analysis.

  19. Development of lightning resistant overhead ground wire and characteristics against lightning current triggered by rocket; Tai rai kaku chisen no kaihatsu to rokketo yurai no jitsuraigeki denryu ni yoru tai rai seino no kensho

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, M.; Yokoya, M.; Kawashima, T. [Chubu Electric Power Co. Inc., Nagoya (Japan); Omi, H. [Sumitomo Electric Industries Ltd., Osaka (Japan); Asano, Y. [Fujikura Ltd., Tokyo (Japan); Goda, Y. [Central Research Inst. of Electric Power Industry, Tokyo (Japan); Nakamura, K. [Nagoya Inst. of Technology, Nagoya (Japan)

    1997-03-20

    It has been important to maintain high reliability for supplying electric power in recent high-intelligent society. Overhead ground wires (GW) are installed at upper positions of overhead transmission lines in order to prevent lightning attack on conductors. As the sacrifice, GW sometimes gets certain damages including strand-breakage by a severe lightning attack. Recently, optical fiber composite ground wire(OPGW), which has arisen for development of strong GW against lightning attack, in particular for transmission lines passing through areas where `winter lightning` with enormous electric charge occurs, or areas where frequent lightning occurs. We investigated materials and strand structures to get high lightning-resistant properties and verified by rocket-triggered lightning experiments and DC arc tests. As the results, we have developed excellent lightning-resistant OPGW that has fundamental properties equivalent to conventional GW. 12 refs., 12 figs., 4 tabs.

  20. Development and application of mechanical calculation and drawing software for conducting wire and ground wire of power transmission line%送电线路导地线力学计算绘图软件的开发与应用

    Institute of Scientific and Technical Information of China (English)

    梁世党

    2012-01-01

      以开发“送电线路导地线力学计算绘图”软件为例,介绍了如何在Excel 2007中利用Visual Basic语言开发一个能快速绘制各种设计气象条件、不同导地线型号的送电线路导地线应力弧垂计算及绘图的应用程序,供工程设计人员在Excel 2007二次开发中作为参考,从而提高绘图效率。%  Taking the development of mechanical calculation and drawing software for conducting wire and ground wire of power transmission line as example, the author presented how to use Excel 2007 and Visual Basic language to develop an application software which permits rapid stress sag calculation and drawing for different types of con⁃ducting wire and ground wire of power transmission line under various meteorological conditions, aiming to provide reference for secondary development of Excel 2007 and higher drawing efficiency.

  1. Wire Chamber

    CERN Multimedia

    Magnetoscriptive readout wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  2. wire chamber

    CERN Multimedia

    1967-01-01

    Magnetoscriptive readout wire chamber.Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  3. wire chamber

    CERN Multimedia

    Proportional multi-wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle. Proportional wire chambers allow a much quicker reading than the optical or magnetoscriptive readout wire chambers.

  4. Validation and modeling of earthquake strong ground motion using a composite source model

    Science.gov (United States)

    Zeng, Y.

    2001-12-01

    Zeng et al. (1994) have proposed a composite source model for synthetic strong ground motion prediction. In that model, the source is taken as a superposition of circular subevents with a constant stress drop. The number of subevents and their radius follows a power law distribution equivalent to the Gutenberg and Richter's magnitude-frequency relation for seismicity. The heterogeneous nature of the composite source model is characterized by its maximum subevent size and subevent stress drop. As rupture propagates through each subevent, it radiates a Brune's pulse or a Sato and Hirasawa's circular crack pulse. The method has been proved to be successful in generating realistic strong motion seismograms in comparison with observations from earthquakes in California, eastern US, Guerrero of Mexico, Turkey and India. The model has since been improved by including scattering waves from small scale heterogeneity structure of the earth, site specific ground motion prediction using weak motion site amplification, and nonlinear soil response using geotechnical engineering models. Last year, I have introduced an asymmetric circular rupture to improve the subevent source radiation and to provide a consistent rupture model between overall fault rupture process and its subevents. In this study, I revisit the Landers, Loma Prieta, Northridge, Imperial Valley and Kobe earthquakes using the improved source model. The results show that the improved subevent ruptures provide an improved effect of rupture directivity compared to our previous studies. Additional validation includes comparison of synthetic strong ground motions to the observed ground accelerations from the Chi-Chi, Taiwan and Izmit, Turkey earthquakes. Since the method has evolved considerably when it was first proposed, I will also compare results between each major modification of the model and demonstrate its backward compatibility to any of its early simulation procedures.

  5. 一起架空地线悬垂线夹挂轴磨损分析%Case Analysis of Suspension Clamp's Shaft Fracture of Overhead Ground Wire

    Institute of Scientific and Technical Information of China (English)

    黄修乾

    2011-01-01

    To solve the line tripping problem caused by the fracture of shaft on suspension clamp of the overhead ground wire of ihe 220 kV Marwan-Xkiaguan Line I , this paper analyzes (he size, texture of the suspension clamp and excludes the quality defect of suspension clamp, and by studying the line design parameters and plan & cross-section drawings, the geographical terrain and weather condition around the tripping location, the field equipment status, and the stress on suspension clamp, the reason of shaft fracture are discussed, li is concluded that the wind along the direction of line and the small vertical load from the suspension clamp are the main reasons leading to the abrasion of suspension clamp and fracture of the shaft. Countermeasures are proposed as precautions.%为解决220kV漫下I回线因架空地线悬垂线夹挂轴断裂引起的线路跳闸问题,通过分析悬垂线夹的尺寸、材质,排除了悬垂线夹存在质量问题;根据线路设计参数及平断面图、故障点地形及气象环境、故障现场设备状况和悬垂线夹受力情况,分析了挂轴断裂的原因,得出顺线路方向风的作用和悬垂线夹所受垂直荷载小是引起悬垂线夹挂轴磨损、断裂的主要原因,并有针对性的提出了相应防范措施.

  6. The SCEC Broadband Platform: Open-Source Software for Strong Ground Motion Simulation and Validation

    Science.gov (United States)

    Goulet, C.; Silva, F.; Maechling, P. J.; Callaghan, S.; Jordan, T. H.

    2015-12-01

    The Southern California Earthquake Center (SCEC) Broadband Platform (BBP) is a carefully integrated collection of open-source scientific software programs that can simulate broadband (0-100Hz) ground motions for earthquakes at regional scales. The BBP scientific software modules implement kinematic rupture generation, low and high-frequency seismogram synthesis using wave propagation through 1D layered velocity structures, seismogram ground motion amplitude calculations, and goodness of fit measurements. These modules are integrated into a software system that provides user-defined, repeatable, calculation of ground motion seismograms, using multiple alternative ground motion simulation methods, and software utilities that can generate plots, charts, and maps. The BBP has been developed over the last five years in a collaborative scientific, engineering, and software development project involving geoscientists, earthquake engineers, graduate students, and SCEC scientific software developers. The BBP can run earthquake rupture and wave propagation modeling software to simulate ground motions for well-observed historical earthquakes and to quantify how well the simulated broadband seismograms match the observed seismograms. The BBP can also run simulations for hypothetical earthquakes. In this case, users input an earthquake location and magnitude description, a list of station locations, and a 1D velocity model for the region of interest, and the BBP software then calculates ground motions for the specified stations. The SCEC BBP software released in 2015 can be compiled and run on recent Linux systems with GNU compilers. It includes 5 simulation methods, 7 simulation regions covering California, Japan, and Eastern North America, the ability to compare simulation results against GMPEs, updated ground motion simulation methods, and a simplified command line user interface.

  7. Air-to-Ground Target Acquisition Source Book: A Review of the Literature

    Science.gov (United States)

    1974-09-30

    its backgrotnid. Middleton (1936) studied the applicability of the C.I.E. metric to that of colored point sources. Konchmieder ( 1924 ) thought that...igated in two studieu per- formed by Rusia , Snyder, and GreeninE, (965u) and Rusis, Snyder, Greening, and Rawlingg (1965b), which repreosent exp erionto...acquisition of ground targets by observers in low-leve: high-speed aircraft. Sandia Laboratory, Albuquerque, New Mexico , SC-TM-66-54, February 1966

  8. Performance and Economic Modeling of Horizontally Drilled Ground-Source Heat Pumps in Select California Climates

    Science.gov (United States)

    Wiryadinata, Steven

    Service life modeling was performed to gage the viability of unitary 3.5 kWt, ground-source terminal heat pumps (GTHP) employing horizontal directionally drilled geothermal heat exchangers (GHX) over air-source terminal heat pumps (PTHP) in hotels and motels and residential apartment building sectors in California's coastal and inland climates. Results suggest the GTHP can reduce hourly peak demand for the utility by 7%-25% compared to PTHP, depending on the climate and building type. The annual energy savings, which range from -1% to 5%, are highly dependent on the GTHP pump energy use relative to the energy savings attributed to the difference in ground and air temperatures (DeltaT). In mild climates with small ?T, the pump energy use may overcome any advantage to utilizing a GHX. The majority of total levelized cost savings - ranging from 0.18/ft2 to 0.3/ft 2 - are due to reduced maintenance and lifetime capital cost normally associated with geothermal heat pump systems. Without these reductions (not validated for the GTHP system studied), the GTHP technology does not appear to offer significant advantages over PTHP in the climate zones studied here. The GTHP levelized cost was most sensitive to variations in installed cost and in some cases, energy use (influenced by climate zone choice), which together highlights the importance of climate selection for installation, and the need for larger market penetration of ground-source systems in order to bring down installed costs as the technology matures.

  9. Simulation of embedded heat exchangers of solar aided ground source heat pump system

    Institute of Scientific and Technical Information of China (English)

    王芳; 郑茂余; 邵俊鹏; 李忠建

    2008-01-01

    Aimed at unbalance of soil temperature field of ground source heat pump system, solar aided energy storage system was established. In solar assisted ground-source heat pump (SAGSHP) system with soil storage, solar energy collected in three seasons was stored in the soil by vertical U type soil exchangers. The heat abstracted by the ground-source heat pump and collected by the solar collector was employed to heating. Some of the soil heat exchangers were used to store solar energy in the soil so as to be used in next winter after this heating period; and the others were used to extract cooling energy directly in the soil by circulation pump for air conditioning in summer. After that solar energy began to be stored in the soil and ended before heating period. Three dimensional dynamic numerical simulations were built for soil and soil heat exchanger through finite element method. Simulation was done in different strata month by month. Variation and restoration of soil temperature were studied. Economy and reliability of long term SAGSHP system were revealed. It can be seen that soil temperature is about 3 ℃ higher than the original one after one year’s running. It is beneficial for the system to operate for long period.

  10. Fundamental study on airborne electromagnetic survey using grounded source; Chihyo source gata kuchu denji tansa no kisoteki kenkyu. 2

    Energy Technology Data Exchange (ETDEWEB)

    Mogi, T.; Fujimitsu, Y. [Kyushu University, Fukuoka (Japan). Faculty of Engineering; Tanaka, Y. [Kyoto University, Kyoto (Japan). Faculty of Science; Jomori, N. [Chiba Electronics Research Institute, Chiba (Japan); Morikawa, T. [Dowa Engineering Co. Ltd., Okayama (Japan); Kusunoki, K. [Central Research Institute of Electric Power Industry, Tokyo (Japan)

    1997-05-27

    With an objective to develop an airborne electromagnetic survey method for greater depths achievable of exploration, a discussion was given on an exploration method of a type in which a transmitting device is placed on the ground to receive signals in an atmosphere. A prototype exploration apparatus is mounted with a fluxgate magnetometer, an attitude meter, a GPS, and a battery. This exploration apparatus is suspended on a 30 meter long rope from a helicopter to perform the exploration. Two flight tests on this apparatus were carried out in the Unzen area, Nagasaki Prefecture and the Motomiya area, Wakayama Prefecture. The ground source was extended to a distance of 1.5 km, and a current of about 20 A was flown with a quiescent wave having four-second cycles. The helicopter flew nearly horizontally at a ground speed of about 50 km, a flight altitude of 450 m above sea level, and a terrain clearances of 100 to 400 m. The obtained data had variations in correspondence with changes in roll and pitch angles, whereas the variation of about 5000 nT was reduced to about 1000 nT as a result of correction. It was not possible, however, to correct completely the variation with short cycles, requiring further discussions on frequency characteristics of the magnetometer. 6 figs., 1 tab.

  11. Gross-beta activity in ground water: natural sources and artifacts of sampling and laboratory analysis

    Science.gov (United States)

    Welch, Alan H.

    1995-01-01

    Gross-beta activity has been used as an indicator of beta-emitting isotopes in water since at least the early 1950s. Originally designed for detection of radioactive releases from nuclear facilities and weapons tests, analysis of gross-beta activity is widely used in studies of naturally occurring radioactivity in ground water. Analyses of about 800 samples from 5 ground-water regions of the United States provide a basis for evaluating the utility of this measurement. The data suggest that measured gross-beta activities are due to (1) long-lived radionuclides in ground water, and (2) ingrowth of beta-emitting radionuclides during holding times between collection of samples and laboratory measurements.Although40K and228Ra appear to be the primary sources of beta activity in ground water, the sum of40K plus228Ra appears to be less than the measured gross-beta activity in most ground-water samples. The difference between the contribution from these radionuclides and gross-beta activity is most pronounced in ground water with gross-beta activities > 10 pCi/L, where these 2 radionuclides account for less than one-half the measured ross-beta activity. One exception is groundwater from the Coastal Plain of New Jersey, where40K plus228Ra generally contribute most of the gross-beta activity. In contrast,40K and228Ra generally contribute most of beta activity in ground water with gross-beta activities measure all beta activity in ground water. Although3H contributes beta activity to some ground water, it is driven from the sample before counting and therefore is not detected by gross-beta measurements. Beta-emitting radionuclides with half-lives shorter than a few days can decay to low values between sampling and counting. Although little is known about concentrations of most short-lived beta-emitting radionuclides in environmental ground water (water unaffected by direct releases from nuclear facilities and weapons tests), their activities are expected to be low.Ingrowth of

  12. wire chamber

    CERN Multimedia

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  13. wire chamber

    CERN Multimedia

    Was used in ISR (Intersecting Storage Ring) split field magnet experiment. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  14. Wire chamber

    CERN Multimedia

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  15. wire chamber

    CERN Multimedia

    1985-01-01

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  16. 国产血管内192Ir线源的放射剂量测定%Dosimetry of a China-made 192Ir wire source

    Institute of Scientific and Technical Information of China (English)

    何昆仑; 王所亭; 高焱章; 周凯欣; 冯宁远; 邱学军

    2001-01-01

    目的对国产血管内192Ir线源的剂量分布进行评价,为动物实验和临床应用提供依据。方法采用Kodak X-omat V慢感光胶片,从平行和垂直于放射源长轴方向进行测量,径向测量时间为25、45、65和82 s,轴向测定时间为25 s,同时进行标准剂量的标定,通过胶片自动分析测量系统分析剂量分布和吸收剂量。参考AAPM TG No.60报告,采用Monte Carlo方法对放射源的辐射剂量进行理论计算,同时与采用AAPM TG No.43报告计算方法进行比较。结果国产血管内192Ir线源具有良好的剂量分布。AAPM TG No.43报告计算方法比Monte Carlo方法高估32%的辐射剂量。结论国产192Ir线源作为血管内放射源是可行的,采用慢感光胶片测定放射源的剂量分布是一种有效手段。%Objective To evaluate the dose releasing rate and the homogeneity of dose distribution of the Chine-made intravascular 192Ir wire source and to provide experimental data of animal study and clinical use. Methods Dosimetry of the 192Ir wire source was measured by Kodak X-omat V film in differents directions and in different exposure lengths.Dose releasing rate of our 192Ir wire source was calculated according to AAPM TG No.60 and Monte Carlo model,and compared with the results by traditional brachytherapy planning system(AAPM TG No.43) Results 192Ir wire source provided with a well-distributed dose around the source,no striking asymmetry was observed.Thirty two percent of dose rate was overestimated by traditional brachytherapy planning system(AAPM TG No.43)comparing with Monte Carlo method. Conclusions The China-made 192Ir wire source is reliable for intravascular radiation.It is an alternative method to measure the dose distribution with Kodak X-omat V film.The dose rate of 192Ir wire source can be estimated by traditional brachytherapy planning system (AAPM TG No.43) and Monte Carlo method.This study may provide a fundation for practicing

  17. Preliminary study of airborne electromagnetic survey using grounded source; Chihyo source gata kuchu denji tansa no kisoteki kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Mogi, T. [Kyushu University, Fukuoka (Japan). Faculty of Engineering; Shimoizumi, M. [Kitakyushu Polytechnic College, Kitakyushu (Japan); Kusunoki, K. [Central Research Institute of Electric Power Industry, Tokyo (Japan); Morikawa, T. [Dowa Engineering Co. Ltd., Okayama (Japan); Jomori, N. [Chiba Electronics Research Institute, Chiba (Japan)

    1996-05-01

    For the development of an airborne electromagnetic prospecting method capable of deeper exploration, a basic study was made about a system wherein a transmitter (source) is positioned on the ground and the receiving is done in the sky. Even in case of this airborne electromagnetic method, the TDEM method is supposedly advantageous over others as in case of groundborne exploration. In the study, the transient response of an airborne vertical magnetic field to a horizontal layered structure was calculated. The current source was 2000m long with a capacity of 30A. The one-layer structure was a 10 Ohm m semi-infinite ground, and the two-layer structure had a 100 Ohm m structure just under the one-layer structure. The result of the calculation suggests that, in the absence of a layer of extremely low resistivity, observation of an approximately 1 second long transient response aboard a helicopter flying at approximately 50km/h will enable an approximately 1000m deep exploration. Problems to affect airborne observation, such as swinging, natural magnetic field fluctuation, and artificially produced noises were investigated by use of a magnetometer suspended from a helicopter in flight. 2 refs., 6 figs.

  18. 石油化工生产装置低压系统接线及接地型式%Wiring and Grounding Types of Low Voltage System in Petrochemical Plants

    Institute of Scientific and Technical Information of China (English)

    任佩佳; 邵文平; 姜旭; 董柏屹

    2016-01-01

    简述低压系统接地的型式,介绍了石油化工生产装置低压系统的接线方式,根据用电负荷特点及工程实际绘制了石油化工生产装置低压系统接线图,探讨关于低压系统三极、四极断路器选择的问题,结合实际分别阐述电动机配电电缆芯数选择问题及变压器中性点工作接地线截面的确定。%Grounding types of low-voltage system were described, wiring of low-voltage system in petrochemical plants was introduced, wiring diagram of low-voltage system in petrochemical plants was drew based on electrical load characteristics and engineering practice, choice of level 3 and level 4 circuit breakers in the low voltage system was discussed. Combined with the actual conditons, selection of the motor power cables was also discussed, and the neutral point grounding wire section of transformer was determined.

  19. On the Design and Response of Domestic Ground-Source Heat Pumps in the UK

    Directory of Open Access Journals (Sweden)

    Chris Underwood

    2014-07-01

    Full Text Available The design and response of ground source heat pumps coupled to vertical closed loop arrays in UK domestic applications are investigated in this article. Two typical UK house types are selected as the vehicle for the study and a detailed dynamic thermal modelling method is used to arrive at time-series heating demands for the two houses. A new empirical heat pump model is derived using experimental data taking into account the deteriorating performance of the heat pump during periods of light load. The heat pump model is incorporated into an existing numerical ground model and completed with a classical effectiveness type heat exchange model of the closed loop array. The model is used to analyse array sizing and performance over an extended time period, as well as sensitivity of the design to soil conductivity and borehole heat exchanger resistance and sensitivity to over-sizing and part-load behavior of the heat pump. Results show that the UK’s standard for ground source design (the Microgeneration Certification Scheme may lead to under-estimated array sizes and that heating system over-sizing and deleterious part-load heat pump performance can add up to 20% to the electrical consumption of these systems.

  20. Study on the Performance of a Ground Source Heat Pump System Assisted by Solar Thermal Storage

    Directory of Open Access Journals (Sweden)

    Yu Jin Nam

    2015-11-01

    Full Text Available A ground source heat pump system (GSHPS utilizes a relatively stable underground temperature to achieve energy-saving for heating and cooling in buildings. However, continuous long-term operation will reduce the soil temperature in winter, resulting in a decline in system performance. In this research, in order to improve the system performance of a GSHPS, a ground heat pump system integrated with solar thermal storage was developed. This solar-assisted ground heat pump system (SAGHPS can both maintain the balance of the soil temperature effectively and achieve higher system performance than the conventional system. In this paper, in order to examine the characteristics of the system, a dynamic simulation was conducted under various conditions. The results of our case study provide specific operation data such as heat exchange rate, heat source temperature, and heat pump COP. As a result, the heat pump COP of SAGHPS was 4.7%, 9.3% higher than that of the GSHPS.

  1. Strong ground motion simulation of the 2016 Kumamoto earthquake of April 16 using multiple point sources

    Science.gov (United States)

    Nagasaka, Yosuke; Nozu, Atsushi

    2017-02-01

    The pseudo point-source model approximates the rupture process on faults with multiple point sources for simulating strong ground motions. A simulation with this point-source model is conducted by combining a simple source spectrum following the omega-square model with a path spectrum, an empirical site amplification factor, and phase characteristics. Realistic waveforms can be synthesized using the empirical site amplification factor and phase models even though the source model is simple. The Kumamoto earthquake occurred on April 16, 2016, with M JMA 7.3. Many strong motions were recorded at stations around the source region. Some records were considered to be affected by the rupture directivity effect. This earthquake was suitable for investigating the applicability of the pseudo point-source model, the current version of which does not consider the rupture directivity effect. Three subevents (point sources) were located on the fault plane, and the parameters of the simulation were determined. The simulated results were compared with the observed records at K-NET and KiK-net stations. It was found that the synthetic Fourier spectra and velocity waveforms generally explained the characteristics of the observed records, except for underestimation in the low frequency range. Troughs in the observed Fourier spectra were also well reproduced by placing multiple subevents near the hypocenter. The underestimation is presumably due to the following two reasons. The first is that the pseudo point-source model targets subevents that generate strong ground motions and does not consider the shallow large slip. The second reason is that the current version of the pseudo point-source model does not consider the rupture directivity effect. Consequently, strong pulses were not reproduced enough at stations northeast of Subevent 3 such as KMM004, where the effect of rupture directivity was significant, while the amplitude was well reproduced at most of the other stations. This

  2. Hysteresis and Soil Site Dependent Input and Hysteretic Energy Spectra for Far-Source Ground Motions

    Directory of Open Access Journals (Sweden)

    Mebrahtom Gebrekirstos Mezgebo

    2016-01-01

    Full Text Available Earthquake input energy spectra for four soil site classes, four hysteresis models, and five ductility levels are developed for far-source ground motion effect. These energy spectra are normalized by a quantity called velocity index (VI. The use of VI allows for the creation of dimensionless spectra and results in smaller coefficients of variation. Hysteretic energy spectra are then developed to address the demand aspect of an energy-based seismic design of structures with 5% critical damping and ductility that ranges from 2 to 5. The proposed input and hysteretic energy spectra are then compared with response spectra generated using nonlinear time history analyses of real ground motions and are found to produce reasonably good results over a relatively large period range.

  3. Investigation of lauric acid dopant as a novel carbon source in MgB{sub 2} wire

    Energy Technology Data Exchange (ETDEWEB)

    Lee, C.M.; Lee, S.M.; Park, G.C.; Joo, J. [School of Advanced Materials Science and Engineering, Sungkyunkwan University, Suwon (Korea, Republic of); Lim, J.H., E-mail: jhlim@stanford.ed [Department of Materials Science and Engineering, Stanford University, Stanford, CA 94305 (United States); Kang, W.N. [BK21 Physics Division and Department of Physics, Sungkyunkwan University, Suwon (Korea, Republic of); Yi, J.H. [School of Advanced Materials Science and Engineering, Sungkyunkwan University, Suwon (Korea, Republic of); Neutron Science Division Laboratory, Korea Atomic Energy Research, Daejeon (Korea, Republic of); Jun, B.-H.; Kim, C.-J. [Neutron Science Division Laboratory, Korea Atomic Energy Research, Daejeon (Korea, Republic of)

    2010-11-01

    We fabricated lauric acid (LA) doped MgB{sub 2} wires and investigated the effects of the LA doping. For the fabrication of the LA-doped MgB{sub 2} wires, B powder was mixed with LA at 0-5 wt.% of the total amount of MgB{sub 2} using an organic solvent, dried, and then the LA-treated B and Mg powders were mixed stoichiometrically. The powder mixture was loaded into an Fe tube and the assemblage was drawn and sintered at 900 deg. C for 3 h under an argon atmosphere. We observed that the LA doping induced the substitution of C for the B sites in MgB{sub 2} and that the actual content of C increased monotonically with increasing LA doping level. The LA-doped MgB{sub 2} wires exhibited a lower critical temperature (T{sub c}), but better critical current density (J{sub c}) behavior in a high magnetic field: the 5 wt.% LA-doped sample had a J{sub c} value of 5.32 x 10{sup 3} A/cm{sup 2}, which was 2.17 times higher than that of the pristine sample (2.45 x 10{sup 3} A/cm{sup 2}) at 5 K and 6 T, suggesting that LA is an effective C dopant in MgB{sub 2} for enhancing the high-field J{sub c} performance.

  4. The Relation Between Ground Acceleration and Earthquake Source Parameters: Theory and Observations

    Science.gov (United States)

    Lior, Itzhak; Ziv, Alon

    2017-04-01

    A simple relation between the root-mean-square of the ground acceleration and earthquake spectral (or source) parameters is introduced: 2 ----f20---- Arms = (2π )Ω0 √--( πκf0-)2, πκT 1 + 1.50.25 where Ω0 is the low frequency displacement spectral plateau, f0 is the corner frequency, κ is an attenuation parameter, and T is the data interval. This result uses the omega-squared model for far-field radiation, and accounts for site-specific attenuation. The main advantage of the new relation with respect to that of Hanks' (Hanks, 1979) is that it relaxes the simplifying assumption that the spectral corner frequency is much smaller than the maximum corner frequency resulting from attenuation, and that the spectrum may be approximated as being perfectly flat between the two frequencies. The newly proposed relation is tested using a composite dataset of earthquake records from Japan, California, Mexico and Taiwan. Excellent agreement is found between observed and predicted ground acceleration for any combination of corner frequencies. Thus, use of the above relation enables the extrapolation of ground motion prediction equation inferred from the frequent small magnitude earthquakes to the rare large magnitudes. This capacity is extremely useful near slow-slip plate boundaries, where the seismic moment release rates are low. Reference Hanks, T. C. (1979). b values and ω-γ seismic source models: implications for tectonic stress variations along active crustal fault zones and the estimation of high-frequency strong ground motion, J. Geophys. Res. 84, 2235-2241.

  5. Source mechanism inversion and ground motion modeling of induced earthquakes in Kuwait - A Bayesian approach

    Science.gov (United States)

    Gu, C.; Toksoz, M. N.; Marzouk, Y.; Al-Enezi, A.; Al-Jeri, F.; Buyukozturk, O.

    2016-12-01

    The increasing seismic activity in the regions of oil/gas fields due to fluid injection/extraction and hydraulic fracturing has drawn new attention in both academia and industry. Source mechanism and triggering stress of these induced earthquakes are of great importance for understanding the physics of the seismic processes in reservoirs, and predicting ground motion in the vicinity of oil/gas fields. The induced seismicity data in our study are from Kuwait National Seismic Network (KNSN). Historically, Kuwait has low local seismicity; however, in recent years the KNSN has monitored more and more local earthquakes. Since 1997, the KNSN has recorded more than 1000 earthquakes (Mw Institutions for Seismology (IRIS) and KNSN, and widely felt by people in Kuwait. These earthquakes happen repeatedly in the same locations close to the oil/gas fields in Kuwait (see the uploaded image). The earthquakes are generally small (Mw < 5) and are shallow with focal depths of about 2 to 4 km. Such events are very common in oil/gas reservoirs all over the world, including North America, Europe, and the Middle East. We determined the location and source mechanism of these local earthquakes, with the uncertainties, using a Bayesian inversion method. The triggering stress of these earthquakes was calculated based on the source mechanisms results. In addition, we modeled the ground motion in Kuwait due to these local earthquakes. Our results show that most likely these local earthquakes occurred on pre-existing faults and were triggered by oil field activities. These events are generally smaller than Mw 5; however, these events, occurring in the reservoirs, are very shallow with focal depths less than about 4 km. As a result, in Kuwait, where oil fields are close to populated areas, these induced earthquakes could produce ground accelerations high enough to cause damage to local structures without using seismic design criteria.

  6. Finite Volume Based Computer Program for Ground Source Heat Pump System

    Energy Technology Data Exchange (ETDEWEB)

    Menart, James A. [Wright State University

    2013-02-22

    This report is a compilation of the work that has been done on the grant DE-EE0002805 entitled ?Finite Volume Based Computer Program for Ground Source Heat Pump Systems.? The goal of this project was to develop a detailed computer simulation tool for GSHP (ground source heat pump) heating and cooling systems. Two such tools were developed as part of this DOE (Department of Energy) grant; the first is a two-dimensional computer program called GEO2D and the second is a three-dimensional computer program called GEO3D. Both of these simulation tools provide an extensive array of results to the user. A unique aspect of both these simulation tools is the complete temperature profile information calculated and presented. Complete temperature profiles throughout the ground, casing, tube wall, and fluid are provided as a function of time. The fluid temperatures from and to the heat pump, as a function of time, are also provided. In addition to temperature information, detailed heat rate information at several locations as a function of time is determined. Heat rates between the heat pump and the building indoor environment, between the working fluid and the heat pump, and between the working fluid and the ground are computed. The heat rates between the ground and the working fluid are calculated as a function time and position along the ground loop. The heating and cooling loads of the building being fitted with a GSHP are determined with the computer program developed by DOE called ENERGYPLUS. Lastly COP (coefficient of performance) results as a function of time are provided. Both the two-dimensional and three-dimensional computer programs developed as part of this work are based upon a detailed finite volume solution of the energy equation for the ground and ground loop. Real heat pump characteristics are entered into the program and used to model the heat pump performance. Thus these computer tools simulate the coupled performance of the ground loop and the heat pump

  7. Recovery Act: Finite Volume Based Computer Program for Ground Source Heat Pump Systems

    Energy Technology Data Exchange (ETDEWEB)

    James A Menart, Professor

    2013-02-22

    This report is a compilation of the work that has been done on the grant DE-EE0002805 entitled Finite Volume Based Computer Program for Ground Source Heat Pump Systems. The goal of this project was to develop a detailed computer simulation tool for GSHP (ground source heat pump) heating and cooling systems. Two such tools were developed as part of this DOE (Department of Energy) grant; the first is a two-dimensional computer program called GEO2D and the second is a three-dimensional computer program called GEO3D. Both of these simulation tools provide an extensive array of results to the user. A unique aspect of both these simulation tools is the complete temperature profile information calculated and presented. Complete temperature profiles throughout the ground, casing, tube wall, and fluid are provided as a function of time. The fluid temperatures from and to the heat pump, as a function of time, are also provided. In addition to temperature information, detailed heat rate information at several locations as a function of time is determined. Heat rates between the heat pump and the building indoor environment, between the working fluid and the heat pump, and between the working fluid and the ground are computed. The heat rates between the ground and the working fluid are calculated as a function time and position along the ground loop. The heating and cooling loads of the building being fitted with a GSHP are determined with the computer program developed by DOE called ENERGYPLUS. Lastly COP (coefficient of performance) results as a function of time are provided. Both the two-dimensional and three-dimensional computer programs developed as part of this work are based upon a detailed finite volume solution of the energy equation for the ground and ground loop. Real heat pump characteristics are entered into the program and used to model the heat pump performance. Thus these computer tools simulate the coupled performance of the ground loop and the heat pump. The

  8. Evaluation of SAR Data as Source of Ground Control Information: First Results

    Science.gov (United States)

    Vassilaki, D. I.; Ioannidis, C.; Stamos, A. A.

    2013-05-01

    The high resolution imaging modes of modern SAR sensors has made SAR data compatible with optical images. SAR data offers various capabilities which can enhance the geometric correction process of optical images (accurate, direct and ground-independent georeferencing capabilities and global DEM products). In this paper the first results of an on-going study on the evaluation of SAR data as source of ground control information for the georeferencing of optical images are presented. The georeferencing of optical images using SAR data is in fact a co-registration problem which involves multimodal, mutitemporal, and multiresolution data. And although 2D transformations have proved to be insufficient for the georeferencing process, as they can not account for the distortions due to terrain, quite a few approaches on the registration of optical to SAR data using 2D-2D transformations can still be found in the literature. In this paper the performance of 2D-2D transformations is compared to the 3D-2D projective transformation over a greater area of Earth's surface with arbitrary terrain type. Two alternative forms of ground control information are used: points and FFLFs. The accuracy of the computed results is obtained using independent CPs and it is compared to the geolocation accuracy specification of the optical image, as well as to the accuracy of exhaustive georeferencing done by third parties.

  9. Case study for ARRA-funded ground-source heat pump (GSHP) demonstration at Oakland University

    Energy Technology Data Exchange (ETDEWEB)

    Im, Piljae [ORNL; Liu, Xiaobing [ORNL

    2015-09-01

    High initial costs and lack of public awareness of ground-source heat pump (GSHP) technology are the two major barriers preventing rapid deployment of this energy-saving technology in the United States. Under the American Recovery and Reinvestment Act (ARRA), 26 GSHP projects have been competitively selected and carried out to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. This paper highlights the findings of a case study of one of the ARRA-funded GSHP demonstration projects, a ground-source variable refrigerant flow (GS-VRF) system installed at the Human Health Building at Oakland University in Rochester, Michigan. This case study is based on the analysis of measured performance data, maintenance records, construction costs, and simulations of the energy consumption of conventional central heating, ventilation, and air-conditioning (HVAC) systems providing the same level of space conditioning as the demonstrated GS-VRF system. The evaluated performance metrics include the energy efficiency of the heat pump equipment and the overall GS-VRF system, pumping performance, energy savings, carbon emission reductions, and cost-effectiveness of the GS-VRF system compared with conventional HVAC systems. This case study also identified opportunities for reducing uncertainties in the performance evaluation, improving the operational efficiency, and reducing the installed cost of similar GSHP systems in the future.

  10. Used motor oil as a source of MTBE, TAME, and BTEX to ground water

    Science.gov (United States)

    Baker, R.J.; Best, E.W.; Baehr, A.L.

    2002-01-01

    Methyl tert-butyl ether (MTBE), the widely used gasoline oxygenate, has been identified as a common ground water contaminant, and BTEX compounds (benzene, toluene, ethylbenzene, and xylenes) have long been associated with gasoline spills. Because not all instances of ground water contamination by MTBE and BTEX can be attributed to spills or leaking storage tanks, other potential sources need to be considered. In this study, used motor oil was investigated as a potential source of these contaminants. MTBE in oil was measured directly by methanol extraction and gas chromatography using a flame ionization detector (GC/FID). Water was equilibrated with oil samples and analyzed for MTBE, BTEX, and the oxygenate tert-amyl methyl ether (TAME) by purge-and-trap concentration followed by GC/FID analysis. Raoult's law was used to calculate oil-phase concentrations of MTBE, BTEX, and TAME from aqueous-phase concentrations. MTBE, TAME, and BTEX were not detected in any of five new motor oil samples, whereas these compounds were found at significant concentrations in all six samples of the used motor oil tested for MTBE and all four samples tested for TAME and BTEX. MTBE concentrations in used motor oil were on the order of 100 mg/L. TAME concentrations ranged from 2.2 to 87 mg/L. Concentrations of benzene were 29 to 66 mg/L, but those of other BTEX compounds were higher, typically 500 to 2000 mg/L.

  11. Ground and flight test experience with a triple redundant digital fly by wire control system. [installed in F-8C aircraft

    Science.gov (United States)

    Jarvis, C. R.; Szalai, K. J.

    1981-01-01

    A triplex digital fly by wire flight control system was developed and installed in an F-8C aircraft to provide fail operative, full authority control. Hardware and software redundancy management techniques were designed to detect and identify failures in the system. Control functions typical of those projected for future actively controlled vehicles were implemented.

  12. 浙北地区地源热泵土壤换热性能测试研究%Study on Measurement of Heat Transfer Characteristics of Ground Source in a Ground Source Heat Pump System in Northern Zhejiang

    Institute of Scientific and Technical Information of China (English)

    刘晓勤; 郑锦龙; 郑翀

    2011-01-01

    The heat transfer characteristics of ground source in Ground Source Heat Pump (GSHP) in Northem Zhejiang were experimentally measured. The experimental results showed that the initial ground source temperature in the coldest month was approximately 17.0℃, which was significantly higher than the temperature of the outside environment. The mean thermal conductivity of the ground source was 1.73W/(m· ℃). It indicated that the ground source had good heat transfer capacity and could be used for the ground source heat pump system. The experimental measurement of the heat transfer coefficient was also conducted on a single U type underground heat exchanger at the depth of 60 m. The experimental results showed that the heat dissipating capacity of the single pipe were 3666W in summer and 2508 W in winter, respectively. The heat dissipating capacity could meet the requirement of the ground source heat pump system.%对浙北地区某地源热泵工程土壤换热性能进行了实验测试,结果显示,浙北地区冬季最冷月地下土壤初始温度稳定在17.0℃左右,远高于室外环境温度;土壤的平均导热系数为1.73W/(m·℃),有较强的地下换热能力,适合做地源热泵系统;对60m深的单U形式地下换热器进行换热性能测试,夏季单根盘管散热量3666W,冬季单根盘管散热量2508W,能满足系统工作要求。

  13. Characterization of Ground Displacement Sources from Variational Bayesian Independent Component Analysis of Space Geodetic Time Series

    Science.gov (United States)

    Gualandi, Adriano; Serpelloni, Enrico; Elina Belardinelli, Maria; Bonafede, Maurizio; Pezzo, Giuseppe; Tolomei, Cristiano

    2015-04-01

    A critical point in the analysis of ground displacement time series, as those measured by modern space geodetic techniques (primarly continuous GPS/GNSS and InSAR) is the development of data driven methods that allow to discern and characterize the different sources that generate the observed displacements. A widely used multivariate statistical technique is the Principal Component Analysis (PCA), which allows to reduce the dimensionality of the data space maintaining most of the variance of the dataset explained. It reproduces the original data using a limited number of Principal Components, but it also shows some deficiencies, since PCA does not perform well in finding the solution to the so-called Blind Source Separation (BSS) problem. The recovering and separation of the different sources that generate the observed ground deformation is a fundamental task in order to provide a physical meaning to the possible different sources. PCA fails in the BSS problem since it looks for a new Euclidean space where the projected data are uncorrelated. Usually, the uncorrelation condition is not strong enough and it has been proven that the BSS problem can be tackled imposing on the components to be independent. The Independent Component Analysis (ICA) is, in fact, another popular technique adopted to approach this problem, and it can be used in all those fields where PCA is also applied. An ICA approach enables us to explain the displacement time series imposing a fewer number of constraints on the model, and to reveal anomalies in the data such as transient deformation signals. However, the independence condition is not easy to impose, and it is often necessary to introduce some approximations. To work around this problem, we use a variational bayesian ICA (vbICA) method, which models the probability density function (pdf) of each source signal using a mix of Gaussian distributions. This technique allows for more flexibility in the description of the pdf of the sources

  14. Sensitivity analysis on the performances of a closed-loop Ground Source Heat Pump

    Science.gov (United States)

    Casasso, Alessandro; Sethi, Rajandrea

    2014-05-01

    Ground Source Heat Pumps (GSHP) permit to achieve a significant reduction of greenhouse gas emissions, and the margins for economic saving of this technology are strongly correlated to the long-term sustainability of the exploitation of the heat stored in the soil. The operation of a GSHP over its lifetime should be therefore modelled considering realistic conditions, and a thorough characterization of the physical properties of the soil is essential to avoid large errors of prediction. In this work, a BHE modelling procedure with the finite-element code FEFLOW is presented. Starting from the governing equations of the heat transport in the soil around a GSHP and inside the BHE, the most important parameters are individuated and the adopted program settings are explained. A sensitivity analysis is then carried on both the design parameters of the heat exchanger, in order to understand the margins of improvement of a careful design and installation, and the physical properties of the soil, with the aim of quantifying the uncertainty induced by their variability. The relative importance of each parameter is therefore assessed by comparing the statistical distributions of the fluid temperatures and estimating the energy consumption of the heat pump, and practical conclusions are from these results about the site characterization, the design and the installation of a BHE. References Casasso A., Sethi R., 2014 Efficiency of closed loop geothermal heat pumps: A sensitivity analysis, Renewable Energy 62 (2014), pp. 737-746 Chiasson A.C., Rees S.J., Spitler J.D., 2000, A preliminary assessment of the effects of groundwater flow on closed-loop ground-source heat pump systems, ASHRAE Transactions 106 (2000), pp. 380-393 Delaleux F., Py X., Olives R., Dominguez A., 2012, Enhancement of geothermal borehole heat exchangers performances by improvement of bentonite grouts conductivity, Applied Thermal Engineering 33-34, pp. 92-99 Diao N., Li Q., Fang Z., 2004, Heat transfer in

  15. Characterization of Site for Installing Open Loop Ground Source Heat Pump System

    Science.gov (United States)

    Yun, S. W.; Park, Y.; Lee, J. Y.; Yi, M. J.; Cha, J. H.

    2014-12-01

    This study was conducted to understand hydrogeological properties of site where open loop ground source heat pump system will be installed and operated. Groundwater level and water temperature were hourly measured at the well developed for usage of open loop ground source heat pump system from 11 October 2013 to 8 January 2014. Groundwater was sampled in January and August 2013 and its chemical and isotopic compositions were analyzed. The bedrock of study area is the Jurassic granodiorite that mainly consists of quartz (27.9 to 46.8%), plagioclase (26.0 to 45.5%), and alkali feldspar (9.5 to 18.7%). The groundwater level ranged from 68.30 to 68.94 m (above mean sea level). Recharge rate was estimated using modified watertable fluctuation method and the recharge ratios was 9.1%. The water temperature ranged from 14.8 to 15.0oC. The vertical Increase rates of water temperature were 1.91 to 1.94/100 m. The water temperature showed the significant seasonal variation above 50 m depth, but had constant value below 50 m depth. Therefore, heat energy of the groundwater can be used securely in open loop ground source heat pump system. Electrical conductivity ranged from 120 to 320 µS/cm in dry season and from 133 to 310 µS/cm in wet season. The electrical conductivity gradually decreased with depth. In particular, electrical conductivity in approximately 30 m depth decreased dramatically (287 to 249 µS/cm) in wet season. The groundwater was Ca-HCO3 type. The concentrations of dissolved components did not show the vertically significant variations from 0 to 250 m depth. The δ18O and δD ranged from -9.5 to -9.4‰ and from -69 to -68‰. This work is supported by the New and Renewable Energy of the Korea Institute of Energy Technology Evaluation and Planning (KETEP) grant funded by the Korea government Ministry of Knowledge Economy (No.20123040110010).

  16. Contamination source review for Building E6891, Edgewood Area, Aberdeen Proving Ground, Maryland

    Energy Technology Data Exchange (ETDEWEB)

    Zellmer, S.D.; Draugelis, A.K.; Rueda, J.; Zimmerman, R.E.

    1995-09-01

    The US Army Aberdeen Proving Ground (APG) commissioned Argonne National Laboratory (ANL) to conduct a contamination source review to identify and define areas of toxic or hazardous contaminants and to assess the physical condition and accessibility of various APG buildings. This report provides the results of the contamination source review for Building E6891. The information obtained from this review may be used to assist the US Army in planning for the future use or disposition of the buildings. The contamination source review consisted of the following tasks: historical records search, physical inspection, photographic documentation, geophysical investigation, and collection of air samples. This building is part of the Lauderick Creek Concrete Slab Test Site, located in the Lauderick Creek Area in the Edgewood Area. Many of the APG facilities constructed between 1917 and the 1960s are no longer used because of obsolescence and their poor state of repair. Because many of these buildings were used for research, development, testing, and/or pilot-scale production of chemical warfare agents and other military substances the potential exists` for portions of the buildings to be contaminated with these substances, their degradation products, and other laboratory or industrial chemicals. These buildings and associated structures or appurtenances may contribute to environmental concerns at APG.

  17. Contamination source review for Building E2370, Edgewood Area, Aberdeen Proving Ground, Maryland

    Energy Technology Data Exchange (ETDEWEB)

    O`Reilly, D.P.; Glennon, M.A.; Draugelis, A.K.; Rueda, J.; Zimmerman, R.E.

    1995-09-01

    The US Army Aberdeen Proving Ground (APG) commissioned Argonne National Laboratory (ANL) to conduct a contamination source review to identify and define areas of toxic or hazardous contaminants and to assess the physical condition and accessibility of APG buildings. The information obtained from this review may be used to assist the US Army in planning for the future use or disposition of the buildings. The contamination source review consisted of the following tasks: historical records search, physical inspection, photographic documentation, and geophysical investigation. This report provides the results of the contamination source review for Building E2370. Many of the APG facilities constructed between 1917 and the 1960s are no longer used because of obsolescence and their poor state of repair. Because many of these buildings were used for research, development, testing, and/or pilot-scale production of chemical warfare agents and other military substances, the potential exists for portions of the buildings to be contaminated with these substances, their degradation products, and other laboratory or industrial chemicals. These buildings and associated structures or appurtenances may contribute to environmental concerns at APG.

  18. Modern wiring practice

    CERN Document Server

    Steward, W E

    2012-01-01

    Continuously in print since 1952, Modern Wiring Practice has now been fully revised to provide an up-to-date source of reference to building services design and installation in the 21st century. This compact and practical guide addresses wiring systems design and electrical installation together in one volume, creating a comprehensive overview of the whole process for contractors and architects, as well as electricians and other installation engineers. Best practice is incorporated throughout, combining theory and practice with clear and accessible explanation, all

  19. Estimation of source location and ground impedance using a hybrid multiple signal classification and Levenberg-Marquardt approach

    Science.gov (United States)

    Tam, Kai-Chung; Lau, Siu-Kit; Tang, Shiu-Keung

    2016-07-01

    A microphone array signal processing method for locating a stationary point source over a locally reactive ground and for estimating ground impedance is examined in detail in the present study. A non-linear least square approach using the Levenberg-Marquardt method is proposed to overcome the problem of unknown ground impedance. The multiple signal classification method (MUSIC) is used to give the initial estimation of the source location, while the technique of forward backward spatial smoothing is adopted as a pre-processer of the source localization to minimize the effects of source coherence. The accuracy and robustness of the proposed signal processing method are examined. Results show that source localization in the horizontal direction by MUSIC is satisfactory. However, source coherence reduces drastically the accuracy in estimating the source height. The further application of Levenberg-Marquardt method with the results from MUSIC as the initial inputs improves significantly the accuracy of source height estimation. The present proposed method provides effective and robust estimation of the ground surface impedance.

  20. An Experimental Facility to Validate Ground Source Heat Pump Optimisation Models for the Australian Climate

    Directory of Open Access Journals (Sweden)

    Yuanshen Lu

    2017-01-01

    Full Text Available Ground source heat pumps (GSHPs are one of the most widespread forms of geothermal energy technology. They utilise the near-constant temperature of the ground below the frost line to achieve energy-efficiencies two or three times that of conventional air-conditioners, consequently allowing a significant offset in electricity demand for space heating and cooling. Relatively mature GSHP markets are established in Europe and North America. GSHP implementation in Australia, however, is limited, due to high capital price, uncertainties regarding optimum designs for the Australian climate, and limited consumer confidence in the technology. Existing GSHP design standards developed in the Northern Hemisphere are likely to lead to suboptimal performance in Australia where demand might be much more cooling-dominated. There is an urgent need to develop Australia’s own GSHP system optimisation principles on top of the industry standards to provide confidence to bring the GSHP market out of its infancy. To assist in this, the Queensland Geothermal Energy Centre of Excellence (QGECE has commissioned a fully instrumented GSHP experimental facility in Gatton, Australia, as a publically-accessible demonstration of the technology and a platform for systematic studies of GSHPs, including optimisation of design and operations. This paper presents a brief review on current GSHP use in Australia, the technical details of the Gatton GSHP facility, and an analysis on the observed cooling performance of this facility to date.

  1. Analysis of Fuel Cell Driven Ground Source Heat Pump Systems in Community Buildings

    Directory of Open Access Journals (Sweden)

    Jong-Keun Shin

    2013-05-01

    Full Text Available In the present study, a fuel cell driven ground source heat pump (GSHP system is applied in a community building and heat pump system performance is analyzed by computational methods. Conduction heat transfer between the brine pipe and ground is analyzed by TEACH code in order to predict the performance of the heat pump system. The predicted coefficient of performance (COP of the heat pump system and the energy cost were compared with the variation of the location of the objective building, the water saturation rate of the soil, and the driven powers of the heat pump system. Compared to the late-night electricity driven system, a significant reduction of energy cost can be accomplished by employing the fuel cell driven heat pump system. This is due to the low cost of electricity production of the fuel cell system and to the application of the recovered waste heat generated during the electricity production process to the heating of the community building.

  2. Regulatory framework and examples of ground-source heating/cooling technology in the Winnipeg area

    Energy Technology Data Exchange (ETDEWEB)

    Matthews, R. [Manitoba Conservation, Winnipeg, MB (Canada)

    2003-07-01

    Winnipeg, Manitoba lies over a highly transmissive Carbonate Aquifer of Ordovician age, which provides a suitable environment for groundwater supply and return wells. Many licensed ground-source heating cooling (GSHC) systems have been installed in and around the Winnipeg urban area over the last several decades. A water rights licence, issued by the Provincial Department of Conservation, is required for all groundwater supply and return wells. This licence comes with certain rights and responsibilities. This paper describes the regulatory framework which governs the licensing process. The author emphasized that the future use and success of the technology depends, in large part, on the development of a critical mass of experienced contractors, hydrogeologists and consulting engineers. 2 refs.

  3. Risk-based prioritization of ground water threatening point sources at catchment and regional scales

    DEFF Research Database (Denmark)

    Overheu, Niels Døssing; Tuxen, Nina; Flyvbjerg, John;

    2014-01-01

    framework has been developed to enable a systematic and transparent risk assessment and prioritization of contaminant point sources, considering the local, catchment, or regional scales (Danish EPA, 2011, 2012). The framework has been tested in several catchments in Denmark with different challenges...... and needs, and two of these are presented. Based on the lessons learned, the Danish EPA has prepared a handbook to guide the user through the steps in a risk-based prioritization (Danish EPA, 2012). It provides guidance on prioritization both in an administratively defined area such as a Danish Region......, and within the bounds of a specified ground water catchment. The handbook presents several approaches in order to prevent the prioritization from foundering because of a lack of data or an inappropriate level of complexity. The developed prioritization tools, possible graphical presentation and use...

  4. Nitrate source indicators in ground water of the Scimitar Subdivision, Peters Creek area, Anchorage, Alaska

    Science.gov (United States)

    Wang, Bronwen; Strelakos, Pat M.; Jokela, Brett

    2000-01-01

    A combination of aqueous chemistry, isotopic measurement, and in situ tracers were used to study the possible nitrate sources, the factors contributing to the spatial distribution of nitrate, and possible septic system influence in the ground water in the Scimitar Subdivision, Municipality of Anchorage, Alaska. Two water types were distinguished on the basis of the major ion chemistry: (1) a calcium sodium carbonate water, which was associated with isotopically heavier boron and with chlorofluorocarbons (CFC's) that were in the range expected from equilibration with the atmosphere (group A water) and (2) a calcium magnesium carbonate water, which was associated with elevated nitrate, chloride, and magnesium concentrations, generally isotopically lighter boron, and CFC's concentrations that were generally in excess of that expected from equilibration with the atmosphere (group B water). Water from wells in group B had nitrate concentrations that were greater than 3 milligrams per liter, whereas those in group A had nitrate concentrations of 0.2 milligram per liter or less. Nitrate does not appear to be undergoing extensive transformation in the ground-water system and behaves as a conservative ion. The major ion chemistry trends and the presence of CFC's in excess of an atmospheric source for group B wells are consistent with waste-water influences. The spatial distribution of the nitrate among wells is likely due to the magnitude of this influence on any given well. Using an expanded data set composed of 16 wells sampled only for nitrate concentration, a significant difference in the static water level relative to bedrock was found. Well water samples with less than 1 milligram per liter nitrate had static water levels within the bedrock, whereas those samples with greater than 1 milligram per liter nitrate had static water levels near or above the top of the bedrock. This observation would be consistent with a conceptual model of a low-nitrate fractured bedrock

  5. Case Study for the ARRA-Funded Ground Source Heat Pump Demonstration at Ball State University

    Energy Technology Data Exchange (ETDEWEB)

    Im, Piljae [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Liu, Xiaobing [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Henderson, Jr., Hugh [CDH Energy Corp., Beijing (China)

    2016-12-01

    With funding provided by the American Recovery and Reinvestment Act (ARRA), 26 ground-source heat pump (GSHP) projects were competitively selected in 2009 to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. One of the selected demonstration projects is a district central GSHP system installed at Ball State University (BSU) in Muncie, IN. Prior to implementing the district GSHP system, 47 major buildings in BSU were served by a central steam plant with four coal-fired and three natural-gas-fired steam boilers. Cooling was provided by five water-cooled centrifugal chillers at the District Energy Station South (DESS). The new district GSHP system replaced the existing coal-fired steam boilers and conventional water-cooled chillers. It uses ground-coupled heat recovery (HR) chillers to meet the simultaneous heating and cooling demands of the campus. The actual performance of the GSHP system was analyzed based on available measured data from August 2015 through July 2016, construction drawings, maintenance records, personal communications, and construction costs. Since Phase 1 was funded in part by the ARRA grant, it is the focus of this case study. The annual energy consumption of the GSHP system was calculated based on the available measured data and other related information. It was compared with the performance of a baseline scenario— a conventional water-cooled chiller and natural-gas-fired boiler system, both of which meet the minimum energy efficiencies allowed by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE 90.1-2013). The comparison was made to determine source energy savings, energy cost savings, and CO2 emission reductions achieved by the GSHP system. A cost analysis was performed to evaluate the simple payback of the GSHP system. The following sections summarize the results of the analysis, the lessons learned, and recommendations for improvement

  6. Heat transfer analysis of underground U-type heat exchanger of ground source heat pump system.

    Science.gov (United States)

    Pei, Guihong; Zhang, Liyin

    2016-01-01

    Ground source heat pumps is a building energy conservation technique. The underground buried pipe heat exchanging system of a ground source heat pump (GSHP) is the basis for the normal operation of an entire heat pump system. Computational-fluid-dynamics (CFD) numerical simulation software, ANSYS-FLUENT17.0 have been performed the calculations under the working conditions of a continuous and intermittent operation over 7 days on a GSHP with a single-well, single-U and double-U heat exchanger and the impact of single-U and double-U buried heat pipes on the surrounding rock-soil temperature field and the impact of intermittent operation and continuous operation on the outlet water temperature. The influence on the rock-soil temperature is approximately 13 % higher for the double-U heat exchanger than that of the single-U heat exchanger. The extracted energy of the intermittent operation is 36.44 kw·h higher than that of the continuous mode, although the running time is lower than that of continuous mode, over the course of 7 days. The thermal interference loss and quantity of heat exchanged for unit well depths at steady-state condition of 2.5 De, 3 De, 4 De, 4.5 De, 5 De, 5.5 De and 6 De of sidetube spacing are detailed in this work. The simulation results of seven working conditions are compared. It is recommended that the side-tube spacing of double-U underground pipes shall be greater than or equal to five times of outer diameter (borehole diameter: 180 mm).

  7. Temperature and energy deficit in the ground during operation and recovery phases of closed-loop ground source heat pump system: Effect of the groundwater flow

    Science.gov (United States)

    Erol, Selcuk; Francois, Bertrand

    2016-04-01

    The advection/dispersion mechanism of the groundwater flow in the ground has a significant effect on a borehole heat exchanger (BHE) to enhance its thermal performance. However, the amount of energy extracted from the ground never disappears and only shifts with the magnitude of the effective thermal velocity in the infinite domain. In this work, we focus on the temperature and the energy balance of the ground in an advection/dispersion dominated heat transfer system during the operation period of a BHE and the subsequent recovery phase when the system is idle. The problem is treated with single BHE and multi-BHEs systems, for different representative geology and different groundwater flow velocity. In order to assess the thermal energy deficit due to heat extraction from the ground, we used the finite line source analytical model, developed recently (Erol et al., 2015) that provides the temperature distributions around the boreholes for discontinuous heat extraction. The model is developed based on the Green's function, which is the solution of heat conduction/advection/dispersion equation in porous media, for discontinuous heat extraction by analytically convoluting rectangular function or pulses in time domain. The results demonstrate the significant positive impact of the groundwater flow for the recovery in terms of temperature deficit at the location of the borehole. However, the total thermal energy deficit is not affected by the groundwater movement. The energy balance of the ground is the same no matter the prevailing heat transfer system, which can be only conduction or advection/dispersion. In addition, the energy balance of the ground is not based on either the duration of the production period operation or of the recovery phase, but depends on the total amount of heat that is extracted and on the bulk volumetric heat capacity of the ground.

  8. Focus group discussions among owners and non-owners of ground source heat pumps

    Energy Technology Data Exchange (ETDEWEB)

    Roberson, B.F.

    1988-07-01

    This research was sponsored by the Office of Buildings and Community Systems and conducted by the Pacific Northwest Laboratory as part of an ongoing effort to enhance the commercial use of federally developed technology. Federal dollars have supported research on the development of ground source heat pumps (GSHP) for several years. Though several companies currently sell GSHP's for residential use, their share of the total heating and air conditioning business remains less than one percent. Large manufacturing companies with national distribution have not yet added GSHP equipment to their product line. GSHP's use only about one half (Braud 1987) to one third (Bose 1987) of the energy needed to operate conventional furnaces and air conditioners. Consequently, a high level of market penetration by the GSHP offers direct benefits to both utility companies and individual users of the systems. Widespread use of these highly efficient systems will reduce both total energy consupmtion, and problems associated with high levels of energy use during peak periods. This will allow utility companies to delay capital expenditures for new facilities to meet the growing energy demand during peak periods. The cost effective use of electricity also reduces the likelihood of homeowners switching to a different fuel source for heating. 5 refs.

  9. Contamination source review for Building E1489, Edgewood Area, Aberdeen Proving Ground, Maryland

    Energy Technology Data Exchange (ETDEWEB)

    Billmark, K.A.; Hayes, D.C.; Draugelis, A.K. [and others

    1995-09-01

    This report was prepared by Argonne National Laboratory (ANL) to document the results of a contamination source review of Building E1489 at the Aberdeen Proving Ground (APG) in Maryland. This report may be used to assist the U.S. Army-in planning for the future use or disposition of this building. The review included a historical records search, physical inspection, photographic documentation, and geophysical investigation. The field investigations were performed in 1994-1995. Building E1489 located in J-Field on the Gunpowder Peninsula in APG`s Edgewood Area housed a power generator that supplied electricity to a nearby observation tower. Building E1489 and the generator were abandoned in 1974, demolished by APG personnel and removed from real estate records. A physical inspection and photographic documentation of Building E1489 were completed by ANL staff during November 1994. In 1994, ANL staff conducted geophysical surveys in the immediate vicinity of Building E1489 by using several nonintrusive methods. Survey results suggest the presence of some underground objects near Building E1489, but they do not provide conclusive evidence of the source of geophysical anomalies observed during the survey. No air monitoring was conducted at the site, and no information on underground storage tanks associated with Building E1489 was available.

  10. 110 kV双回线路管型复合材料杆避雷线架设与接地方案研究%Erection Scheme of Overhead Grounding Wire on Composite Material Pole and Its Grounding for 110 kV Double Circuit Overhead Transmission Lines

    Institute of Scientific and Technical Information of China (English)

    李志军; 陈维江; 戴敏; 李志政; 李汉明; 邓世聪

    2014-01-01

    我国学者尝试在雷电活动强烈、污秽严重地区的110 kV架空线路应用复合材料绝缘杆,以提高相对地空气间隙距离和爬电距离。然而绝缘水平的提高,复合材料杆还是否需要架设避雷线以及避雷线接地引下线,是防雷面临的关键技术问题之一。针对典型110 kV复合材料杆,对比研究未架设避雷线的复合材料杆与架设避雷线的同电压等级、相同导线高度铁塔线路的雷电性能,考虑2种杆塔线路引雷能力、雷电冲击绝缘强度以及建弧率等因素的差异,发现:2种杆塔线路引雷能力间的差异可以忽略;未架设避雷线的复合材料杆雷电冲击绝缘强度是铁塔的3.5倍,建弧率为铁塔的53%,但是反击耐雷水平仅为24.5 kA,雷击跳闸率高达1.13次/(100 km⋅a),均明显劣于铁塔。据此,推荐110 kV复合材料杆架设避雷线。然后,对比估算避雷线不同接地方案下雷电性能的差异发现:避雷线若不经引下线接地,则复合材料杆雷电性能明显劣于铁塔,但若经引下线逐杆接地,则雷电性能显著优于铁塔。因此,提出避雷线应逐杆接地。综上所述,110 kV 复合材料杆线路防雷接地方案应当采用架设避雷线,且通过金属引下线逐杆接地的设计。%It is attempted for Chinese scholars to apply insulation pole composed of composite material in the erection of 110 kV overhead transmission lines located at the regions with strong lightning activity and/or serious pollution to enhance the phase-to-ground air gap distance and creepage distance effectively. However, with the enhancement of insulation level whether the overhead ground wire should be erected on the composite material pole as well as its grounding downlead should be equipped are key problems that the lightning protection technology has to be faced with. As to the composite material pole for 110 kV transmission lines, the lightning

  11. Hydrogeology, ground-water quality, and source of ground water causing water-quality changes in the Davis well field at Memphis, Tennessee

    Science.gov (United States)

    Parks, William S.; Mirecki, June E.; Kingsbury, James A.

    1995-01-01

    An investigation was conducted by the U.S. Geological Survey from 1992 to 1994 to collect and interpret hydrogeologic and water-quality data to determine the source of ground water causing water-quality changes in water from wells screened in the Memphis aquifer in the Davis well field at Memphis, Tennessee. Water-quality changes in aquifers used for water supply are of concern because these changes can indicate a potential for contamination of the aquifers by downward leakage from near-surface sources.

  12. Polarization measurements through space-to-ground atmospheric propagation paths by using a highly polarized laser source in space.

    Science.gov (United States)

    Toyoshima, Morio; Takenaka, Hideki; Shoji, Yozo; Takayama, Yoshihisa; Koyama, Yoshisada; Kunimori, Hiroo

    2009-12-07

    The polarization characteristics of an artificial laser source in space were measured through space-to-ground atmospheric transmission paths. An existing Japanese laser communication satellite and optical ground station were used to measure Stokes parameters and the degree of polarization of the laser beam transmitted from the satellite. As a result, the polarization was preserved within an rms error of 1.6 degrees, and the degree of polarization was 99.4+/-4.4% through the space-to-ground atmosphere. These results contribute to the link estimation for quantum key distribution via space and provide the potential for enhancements in quantum cryptography worldwide in the future.

  13. Kinematic source model for simulation of near-fault ground motion field using explicit finite element method

    Institute of Scientific and Technical Information of China (English)

    Zhang Xiaozhi; Hu Jinjun; Xie Lili; Wang Haiyun

    2006-01-01

    This paper briefly reviews the characteristics and major processes of the explicit finite element method in modeling the near-fault ground motion field. The emphasis is on the finite element-related problems in the finite fault source modeling. A modified kinematic source model is presented, in which vibration with some high frequency components is introduced into the traditional slip time function to ensure that the source and ground motion include sufficient high frequency components. The model presented is verified through a simple modeling example. It is shown that the predicted near-fault ground motion field exhibits similar characteristics to those observed in strong motion records, such as the hanging wall effect, vertical effect, fling step effect and velocity pulse effect, etc.

  14. Key Ground-Based and Space-Based Assets to Disentangle Magnetic Field Sources in the Earth's Environment

    Science.gov (United States)

    Chulliat, A.; Matzka, J.; Masson, A.; Milan, S. E.

    2016-10-01

    The magnetic field measured on the ground or in space is the addition of several sources: from flows within the Earth's core to electric currents in distant regions of the magnetosphere. Properly separating and characterizing these sources requires appropriate observations, both ground-based and space-based. In the present paper, we review the existing observational infrastructure, from magnetic observatories and magnetometer arrays on the ground to satellites in low-Earth (Swarm) and highly elliptical (Cluster) orbits. We also review the capability of SuperDARN to provide polar ionospheric convection patterns supporting magnetic observations. The past two decades have been marked by exciting new developments in all observation types. We review these developments, focusing on how they complement each other and how they have led or could lead in the near future to improved separation and modeling of the geomagnetic sources.

  15. Stimulation of whistler activity by an artificial ground-based low frequency acoustic wave source

    Science.gov (United States)

    Soroka, Silvestr; Kim, Vitaly; Khegay, Valery; Kalita, Bogdan

    This paper presents some results of an active experiment aimed to impact the ionosphere with low frequency acoustic waves artificially generated in the near-ground atmosphere. The main goal of the experiment was checking if the artificially generated acoustic waves could affect whistler occurrence at middle latitudes. As a source of acoustic waves we used twin powerful sonic speakers. One of which produced acoustic waves at a frequency of 600 Hz while the other one at a frequency of 624 Hz with intensity of 160 dB at a distance of 1 m away from end of the horn. The duration of sonic pulse was one minute. As a result of acoustic wave interference above the acoustic wave source there appears some kind of a virtual sonic antenna that radiates lower frequency acoustic waves at a frequency being equal to the difference of the two initially generated frequencies (624 Hz - 600 Hz = 24 Hz). The resulting acoustic wave is capable to penetrate to higher altitudes than the initially generated waves do because of its lower frequency. A whistler detector was located at about 100 m far away from the acoustic wave source. We performed the 50 experiments at Lviv (49.50° N, 24.00° E) with acoustic influence on the atmosphere-ionosphere system. The obtained results indicate that the emitted low frequency acoustic waves were clearly followed by enhanced whistler occurrence. We suggest that the observations could be interpreted how increase of transparency of ionosphere and upward refraction of VLF spherics resulted from modulation of local atmospheric parameters by the acoustic waves. These two effects produce to the increase of amount of the whistlers.

  16. Ground-Source Integrated Heat Pump for Near-Zero Energy Houses: Technology Status Report

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, Richard W [ORNL; Rice, C Keith [ORNL; Baxter, Van D [ORNL; Craddick, William G [ORNL

    2007-09-01

    . With the greater energy savings the cost of the more energy efficient components required for the IHP can be recovered more quickly than if they were applied to individual pieces of equipment to meet each individual energy service need. An IHP can be designed to use either outdoor air or geothermal resources (e.g., ground, ground water, surface water) as the environmental energy source/sink. Based on a scoping study of a wide variety of possible approaches to meeting the energy service needs for a ZEH, DOE selected the IHP concept as the most promising and has supported research directed toward the development of both air- and ground-source versions. This report describes the ground-source IHP (GS-IHP) design and includes the lessons learned and best practices revealed by the research and development (R&D) effort throughout. Salient features of the GS-IHP include a variable-speed rotary compressor incorporating a brushless direct current permanent magnet motor which provides all refrigerant compression, a variable-speed fan for the indoor section, a multiple-speed ground coil circuit pump, and a single-speed pump for water heating operation. Laboratory IHP testing has thus far used R-22 because of the availability of the needed components that use this refrigerant. It is expected that HFC R-410A will be used for any products arising from the IHP concept. Data for a variable-speed compressor that uses R-410A has been incorporated into the DOE/ORNL Mark VI Heat Pump Design Model (HPDM). HPDM was then linked to TRNSYS, a time-series-dependent simulation model capable of determining the energy use of building cooling and heating equipment as applied to a defined house on a sub-hourly basis. This provided a highly flexible design analysis capability for advanced heat pump equipment; however, the program also took a relatively long time to run. This approach was used with the initial prototype design reported in Murphy et al. (2007a) and in the business case analysis of

  17. 30 CFR 56.12047 - Guy wires.

    Science.gov (United States)

    2010-07-01

    ... wires of poles supporting high-voltage transmission lines shall meet the requirements for grounding or... Installation and Maintenance of Electric Supply and Communication Lines” (also referred to as National...

  18. Modelling the Source of Blasting for the Numerical Simulation of Blast-Induced Ground Vibrations: A Review

    Science.gov (United States)

    Ainalis, Daniel; Kaufmann, Olivier; Tshibangu, Jean-Pierre; Verlinden, Olivier; Kouroussis, Georges

    2017-01-01

    The mining and construction industries have long been faced with considerable attention and criticism in regard to the effects of blasting. The generation of ground vibrations is one of the most significant factors associated with blasting and is becoming increasingly important as mining sites are now regularly located near urban areas. This is of concern to not only the operators of the mine but also residents. Mining sites are subjected to an inevitable compromise: a production blast is designed to fragment the utmost amount of rock possible; however, any increase in the blast can generate ground vibrations which can propagate great distances and cause structural damage or discomfort to residents in surrounding urban areas. To accurately predict the propagation of ground vibrations near these sensitive areas, the blasting process and surrounding environment must be characterised and understood. As an initial step, an accurate model of the source of blast-induced vibrations is required. This paper presents a comprehensive review of the approaches to model the blasting source in order to critically evaluate developments in the field. An overview of the blasting process and description of the various factors which influence the blast performance and subsequent ground vibrations are also presented. Several approaches to analytically model explosives are discussed. Ground vibration prediction methods focused on seed waveform and charge weight scaling techniques are presented. Finally, numerical simulations of the blasting source are discussed, including methods to estimate blasthole wall pressure time-history, and hydrodynamic codes.

  19. Quantifying Systemic Efficiency using Exergy and Energy Analysis for Ground Source Heat Pumps: Domestic Space Conditioning and Water Heating Applications.

    Energy Technology Data Exchange (ETDEWEB)

    Ally, Moonis Raza [ORNL; Baxter, Van D [ORNL; Gehl, Anthony C [ORNL; Munk, Jeffrey D [ORNL

    2017-01-01

    Although air temperatures over land surfaces show wide seasonal and daily variations, the ground, approximately 10 meters below the earth s surface, remains relatively stable in temperature thereby serving as an energy source or sink. Ground source heat pumps can heat, cool, and supply homes with hot water efficiently by utilizing the earth s renewable and essentially inexhaustible energy resources, saving fossil fuels, reducing greenhouse gas emissions, and lowering the environmental footprint. In this paper, evidence is shown that ground source heat pumps can provide up to 79%-87% of domestic hot water energy needs, and up to 77% of space heating needs with the ground s thermal energy resources. The case refers to a 12-month study conducted at a 253 m2 research house located in Oak Ridge, Tennessee, 36.01 N 84.26 W in a mixed-humid climate with HDD of 2218 C-days and CDD of 723 C-days under simulated occupancy conditions. A single 94.5m vertical bore interfaced the heat pump with the ground. The research shows that this technology is capable of achieving US DOE targets of 25 % and 35% energy savings in HVAC, and in water heating, respectively by 2030. It is also a viable technology to meet greenhouse gas target emissions under the IECC 2012 Standard, as well as the European Union (EU) 2020 targets of using renewable energy resources. The paper quantifies systemic efficiencies using Exergy analysis of the major components, clearly pointing areas for further improvement.

  20. Measurement of ground displacement from optical satellite image correlation using the free open-source software MicMac

    Science.gov (United States)

    Rosu, Ana-Maria; Pierrot-Deseilligny, Marc; Delorme, Arthur; Binet, Renaud; Klinger, Yann

    2015-02-01

    Image correlation is one of the most efficient techniques to determine horizontal ground displacements due to earthquakes, landslides, ice flows or sand dune migrations. Analyzing these deformations allows a better understanding of the causes and mechanisms of the events. By using sub-pixel correlation on before- and after-event ortho-images obtained from high resolution satellite images it is possible to compute the displacement field with high planimetric resolution. In this paper, we focus on measuring the ground displacements due to seismotectonic events. The three sub-pixel correlators used are: COSI-Corr - developed by Caltech, a free, closed-source correlator, dependent on commercial software (ENVI) and widely used by the geoscience community for measuring ground displacement; Medicis - developed by CNES, also a closed-source correlator capable of measuring this type of deformation; and MicMac - developed by IGN, the free open-source correlator we study and tune for measuring fine ground displacements. We measured horizontal ground deformation using these three correlators on SPOT images in three study cases: the 2001 Kokoxili earthquake, the 2005 dyke intrusion in the Afar depression and the 2008 Yutian earthquake.

  1. Spent coffee grounds, an innovative source of colonic fermentable compounds, inhibit inflammatory mediators in vitro.

    Science.gov (United States)

    López-Barrera, Dunia Maria; Vázquez-Sánchez, Kenia; Loarca-Piña, Ma Guadalupe Flavia; Campos-Vega, Rocio

    2016-12-01

    Spent coffee grounds (SCG), rich in dietary fiber can be fermented by colon microbiota producing short-chain fatty acids (SCFAs) with the ability to prevent inflammation. We investigated SCG anti-inflammatory effects by evaluating its composition, phenolic compounds, and fermentability by the human gut flora, SCFAs production, nitric oxide and cytokine expression of the human gut fermented-unabsorbed-SCG (hgf-NDSCG) fraction in LPS-stimulated RAW 264.7 macrophages. SCG had higher total fiber content compared with coffee beans. Roasting level/intensity reduced total phenolic contents of SCG that influenced its colonic fermentation. Medium roasted hgf-NDSCG produced elevated SCFAs (61:22:17, acetate, propionate and butyrate) after prolonged (24h) fermentation, suppressed NO production (55%) in macrophages primarily by modulating IL-10, CCL-17, CXCL9, IL-1β, and IL-5 cytokines. SCG exerts anti-inflammatory activity, mediated by SCFAs production from its dietary fiber, by reducing the release of inflammatory mediators, providing the basis for SCG use in the control/regulation of inflammatory disorders. The results support the use of SGC in the food industry as dietary fiber source with health benefits.

  2. Hybrid Ground-Source Heat Pump Installations: Experiences, Improvements, and Tools

    Energy Technology Data Exchange (ETDEWEB)

    Scott Hackel; Amanda Pertzborn

    2011-06-30

    One innovation to ground-source heat pump (GSHP, or GHP) systems is the hybrid GSHP (HyGSHP) system, which can dramatically decrease the first cost of GSHP systems by using conventional technology (such as a cooling tower or a boiler) to meet a portion of the peak heating or cooling load. This work uses three case studies (two cooling-dominated, one heating-dominated) to demonstrate the performance of the hybrid approach. Three buildings were studied for a year; the measured data was used to validate models of each system. The models were used to analyze further improvements to the hybrid approach, and establish that this approach has positive impacts, both economically and environmentally. Lessons learned by those who design and operate the systems are also documented, including discussions of equipment sizing, pump operation, and cooling tower control. Finally, the measured data sets and models that were created during this work are described; these materials have been made freely available for further study of hybrid systems.

  3. gprMax: Open source software to simulate electromagnetic wave propagation for Ground Penetrating Radar

    Science.gov (United States)

    Warren, Craig; Giannopoulos, Antonios; Giannakis, Iraklis

    2016-12-01

    gprMax is open source software that simulates electromagnetic wave propagation, using the Finite-Difference Time-Domain (FDTD) method, for the numerical modelling of Ground Penetrating Radar (GPR). gprMax was originally developed in 1996 when numerical modelling using the FDTD method and, in general, the numerical modelling of GPR were in their infancy. Current computing resources offer the opportunity to build detailed and complex FDTD models of GPR to an extent that was not previously possible. To enable these types of simulations to be more easily realised, and also to facilitate the addition of more advanced features, gprMax has been redeveloped and significantly modernised. The original C-based code has been completely rewritten using a combination of Python and Cython programming languages. Standard and robust file formats have been chosen for geometry and field output files. New advanced modelling features have been added including: an unsplit implementation of higher order Perfectly Matched Layers (PMLs) using a recursive integration approach; diagonally anisotropic materials; dispersive media using multi-pole Debye, Drude or Lorenz expressions; soil modelling using a semi-empirical formulation for dielectric properties and fractals for geometric characteristics; rough surface generation; and the ability to embed complex transducers and targets.

  4. Geothermal(Ground-Source)Heat Pumps: Market Status, Barriers to Adoption, and Actions to Overcome Barriers

    Energy Technology Data Exchange (ETDEWEB)

    Hughes, Patrick [ORNL

    2008-12-01

    More effective stewardship of our resources contributes to the security, environmental sustainability, and economic well-being of the nation. Buildings present one of the best opportunities to economically reduce energy consumption and limit greenhouse gas emissions. Geothermal heat pumps (GHPs), sometimes called ground-source heat pumps, have been proven capable of producing large reductions in energy use and peak demand in buildings. However, GHPs have received little attention at the policy level as an important component of a national strategy. Have policymakers mistakenly overlooked GHPs, or are GHPs simply unable to make a major contribution to the national goals for various reasons? This brief study was undertaken at DOE's request to address this conundrum. The scope of the study includes determining the status of global GHP markets and the status of the GHP industry and technology in the United States, assembling previous estimates of GHP energy savings potential, identifying key barriers to application of GHPs, and identifying actions that could accelerate market adoption of GHPs. The findings are documented in this report along with conclusions and recommendations.

  5. Evaluation of federal and state subsidies for ground-source heat pumps

    Energy Technology Data Exchange (ETDEWEB)

    Blumsack, S.; Kleit, A. [Department of Energy and Mineral Engineering, The Pennsylvania State University, 213 Hosler Building University Park, PA (United States); Smith, S.W. [Westcott Consulting, 110 Hosler Building, Boulder, CO (United States)

    2012-08-15

    Energy efficiency can be a powerful way to lower energy bills, as well as the external (social) costs associated with energy consumption. Previous experience and research, however, has demonstrated that consumers are often unwilling to make investments in energy efficiency, even when such investments have relatively short payback periods. Because energy efficiency can contribute to correcting negative externalities associated with energy use, subsidies and other programs have been proposed as a way to increase efficiency investments. Thus, under the right circumstances, such subsidies can improve economic efficiency. In this paper, we analyze the economics of energy-efficient space conditioning using data from an actual household in rural Pennsylvania to evaluate ground-source heat pumps (GHP). GHP technology has been advocated as a potentially appealing energy efficiency measure for rural communities. We find that with current subsidies GHP is economically viable for a wide range of electricity prices. We also find, however, that current subsidies are actually greater than those that can be economically justified. Using the efficient level of subsidies reduces, but does not eliminate, the economic case for GHP technology. We also evaluate the economics of efficiency subsidies using an ambitious program in Pennsylvania as a case study. The program, known as the Alternative Energy Investment Act (AEIA), provides subsidies for GHP among other technologies. We find that the substantial federal subsidies for GHP undercut the economic efficiency arguments for the AEIA with respect to GHP.

  6. Domestic Hot Water Production with Ground Source Heat Pump in Apartment Buildings

    Directory of Open Access Journals (Sweden)

    Jukka Yrjölä

    2015-08-01

    Full Text Available Producing domestic hot water (DHW with a ground source heat pump (GSHP is challenging due to the high temperature (HT of DHW. There are many studies proving the better performance of cascade heat pumps compared to single-stage heat pumps when the difference between the condensing and the evaporation temperature is large. In this system approach study, different GSHP arrangements are described and computationally compared. A two-stage heat pump arrangement is introduced in which water tanks of the heating system are utilized for warming up the DHW in two stages. It is shown that the electricity consumption with this two-stage system is approximately 31% less than with the single-stage heat pump and 12% less than with the cascade system. Further, both low temperature (LT and HT heat pumps can run alone, which is not common in cascade or other two-stage heat pumps. This is advantageous because the high loads of the space heating and DHW production are not simultaneous. Proper insulation of the DHW and recirculation pipe network is essential, and drying towel rails or other heating coils should be avoided when aiming for a high efficiency. The refrigerants in the calculations are R407C for the LT heat pump and R134a for the HT heat pump. Investment costs are excluded from calculations.

  7. Contamination source review for Building E3180, Edgewood Area, Aberdeen Proving Ground, Maryland

    Energy Technology Data Exchange (ETDEWEB)

    Zellmer, S.D.; Smits, M.P.; Rueda, J.; Zimmerman, R.E.

    1995-09-01

    This report was prepared by Argonne National Laboratory (ANL) to document the results of a contamination source review of Building E3180 at the Aberdeen Proving Ground (APG) in Maryland. The report may be used to assist the US Army in planning for the future use or disposition of this building. The review included a historical records search, physical inspection, photographic documentation, geophysical investigation, collection of air samples, and review of available records regarding underground storage tanks associated with Building E3180. The field investigations were performed by ANL during 1994. Building,E3180 (current APG designation) is located near the eastern end of Kings Creek Road, north of Kings Creek, and about 0.5 miles east of the airstrip within APG`s Edgewood Area. The building was constructed in 1944 as a facsimile of a Japanese pillbox and used for the development of flame weapons systems until 1957 (EAI Corporation 1989). The building was not used from 1957 until 1965, when it was converted and used as a flame and incendiary laboratory. During the 1970s, the building was converted to a machine (metal) shop and used for that purpose until 1988.

  8. Contamination source review for Building E3162, Edgewood Area, Aberdeen Proving Ground, Maryland

    Energy Technology Data Exchange (ETDEWEB)

    Miller, G.A.; Draugelis, A.K.; Rueda, J.; Zimmerman, R.E.

    1995-09-01

    This report was prepared by Argonne National Laboratory (ANL) to document the results of a contamination source review for Building E3162 at the Aberdeen Proving Ground (APG) in Maryland. The report may be used to assist the US Army in planning for the future use or disposition of this building. The review included a historical records search, physical inspection, photographic documentation, geophysical investigation, and collection of air samples. The field investigations were performed by ANL during 1994 and 1995. Building E3162 (APG designation) is part of the Medical Research Laboratories Building E3160 Complex. This research laboratory complex is located west of Kings Creek, east of the airfield and Ricketts Point Road, and south of Kings Creek Road in the Edgewood Area of APG. The original structures in the E3160 Complex were constructed during World War 2. The complex was originally used as a medical research laboratory. Much of the research involved wound assessment involving chemical warfare agents. Building E3162 was used as a holding and study area for animals involved in non-agent burns. The building was constructed in 1952, placed on inactive status in 1983, and remains unoccupied. Analytical results from these air samples revealed no distinguishable difference in hydrocarbon and chlorinated solvent levels between the two background samples and the sample taken inside Building E3162.

  9. Application analysis of ground source heat pumps in building space conditioning

    Energy Technology Data Exchange (ETDEWEB)

    Qian, Hua; Wang, Yungang

    2013-07-01

    The adoption of geothermal energy in space conditioning of buildings through utilizing ground source heat pump (GSHP, also known as geothermal heat pump) has increased rapidly during the past several decades. However, the impacts of the GSHP utilization on the efficiency of heat pumps and soil temperature distribution remained unclear and needs further investigation. This paper presents a novel model to calculate the soil temperature distribution and the coefficient of performance (COP) of GSHP. Different scenarios were simulated to quantify the impact of different factors on the GSHP performance, including heat balance, daily running mode, and spacing between boreholes. Our results show that GSHP is suitable for buildings with balanced cooling and heating loads. It can keep soil temperature at a relatively constant level for more than 10 years. Long boreholes, additional space between boreholes, intermittent running mode will improve the performance of GSHP, but large initial investment is required. The improper design will make the COP of GSHP even lower than traditional heat pumps. Professional design and maintenance technologies are greatly needed in order to promote this promising technology in the developing world.

  10. Wire Chamber

    CERN Multimedia

    1986-01-01

    Two wire chambers made originally for the R807 Experiment at CERN's Intersecting Storage Rings. In 1986 they were used for the PS 201 experiment (Obelix Experiment) at LEAR, the Low Energy Antiproton Ring. The group of researchers from Turin, using the chambers at that time, changed the acquisition system using for the first time 8 bit (10 bit non linear) analog to digital conversion for incoming signals from the chambers. The acquisition system was controlled by 54 CPU and 80 digital signal processors. The power required for all the electronics was 40 kW. For the period, this system was one of the most powerful on-line apparatus in the world. The Obelix Experiment was closed in 1996. To find more about how a wire chamber works, see the description for object CERN-OBJ-DE-038.

  11. Simulation and optimisation of a ground source heat pump with different ground heat exchanger configurations for a single-family residential house

    DEFF Research Database (Denmark)

    Pavlov, Georgi Krasimiroy; Olesen, Bjarne W.

    2012-01-01

    In the future there will be an increased demand for energy efficient cooling of residential buildings. Therefore it is essential to develop cooling concepts that are passive and/or using very little primary energy. A possible solution is a ground source heat pump combined with a low....... For the studied geographical location, passive cooling by bypassing the heat pump and using only the ground heat exchanger can provide acceptable room temperatures.......-temperature heating and high-temperature cooling system. The present work evaluates the performance in relation to thermal comfort and energy consumption of a GSHP with different GHE concepts. The different configurations are analyzed being part of the energy supply system of a low-energy residential house...

  12. Optimization design and compare of different solar-ground source heat pump system of office building in cold regions

    Science.gov (United States)

    Xie, H.; He, S.; Fu, Y.

    2016-08-01

    This paper presents two different operation modes of Solar-Ground Source Heat Pump System (SGSHP(S)). With the simulation tool TRNSYS, two different SGSHP system models were built to taking simulation. After making analysis and compare of different simulation results, series operation mode was believed to be better than parallel in the target building.

  13. On the Technology of Ground Source Heat Pump%浅谈地源热泵技术

    Institute of Scientific and Technical Information of China (English)

    屈东升

    2012-01-01

    The concept of ground source heat pump technology is described. The working principle and classification, the composition of ground source heat pump is introduced. The characteristics and actual application of ground source heat pump is analyzed. It is pointed out that the ground source heat pump which is a renewable energy has broad developing and applying prospects in energy saving and exhaustion-reducing, environmental protection, sustainable development in our country.%阐述地源热泵技术的概念。介绍地源热泵系统的组成部分、工作原理和分类,分析地源热泵系统的特点和实际应用情况。提出地源热泵这种可再生能源在我国节能降耗、生态环保、可持续发展中具有广阔的发展和应用前景。

  14. Age and quality of ground water and sources of nitrogen in the aquifers in Pumpkin Creek Valley, western Nebraska, 2000

    Science.gov (United States)

    Steele, G.V.; Cannia, J.C.; Sibray, S.S.; McGuire, V.L.

    2005-01-01

    Ground water is the source of drinking water for the residents of Pumpkin Creek Valley, western Nebraska. In this largely agricultural area, shallow aquifers potentially are susceptible to nitrate contamination. During the last 10 years, ground-water levels in the North Platte Natural Resources District have declined and contamination has become a major problem for the district. In 2000, the U.S. Geological Survey and the North Platte Natural Resources District began a cooperative study to determine the age and quality of the ground water and the sources of nitrogen in the aquifers in Pumpkin Creek Valley. Water samples were collected from 8 surface-water sites, 2 springs, and 88 ground-water sites during May, July, and August 2000. These samples were analyzed for physical properties, nutrients or nitrate, and hydrogen and oxygen isotopes. In addition, a subset of samples was analyzed for any combination of chlorofluorocarbons, tritium, tritium/helium, sulfur-hexafluoride, carbon-14, and nitrogen-15. The apparent age of ground water in the alluvial aquifer typically varied from about 1980 to modern, whereas ground water in the fractured Brule Formation had a median value in the 1970s. The Brule Formation typically contained ground water that ranged from the 1940s to the 1990s, but low-yield wells had apparent ages of 5,000 to 10,000 years before present. Data for oxygen-18 and deuterium indicated that lake-water samples showed the greatest effects from evaporation. Ground-water data showed no substantial evaporative effects and some ground water became isotopically heavier as the water moved downgradient. In addition, the physical and chemical ground-water data indicate that Pumpkin Creek is a gaining stream because little, if any, of its water is lost to the ground-water system. The water-quality type changed from a sodium calcium bicarbonate type near Pumpkin Creek's headwaters to a calcium sodium bicarbonate type near its mouth. Nitrate concentrations were

  15. Diameter control of gold nanoparticles synthesized in gas phase using atmospheric-pressure H2/Ar plasma jet and gold wire as the nanoparticle source: Control by varying the H2/Ar mixture ratio

    Science.gov (United States)

    Shimizu, Yoshiki

    2017-01-01

    This report describes diameter control of gold nanoparticles (AuNPs) during synthesis using an atmospheric-pressure H2/Ar plasma jet drive with pulse-modulated ultrahigh frequency, employing Au wire as the NP source material. During this process, where most of the AuNPs are regarded as formed through condensation from Au vapor derived by the Au wire etching, the mean diameter varied in the approximate range of 2-12 nm with H2 volume ratios up to 3.9%. In plasma diagnostics, results showed that the H2 volume ratio influences the plasma discharge behaviour, which affects the heat flux density flowed into the Au wire, and the atomic hydrogen concentration in the plasma. Both seemed to influence the etching rate of the Au wire per unit area, which is directly related to the concentration of Au vapor in the plasma. The concentration is one factor affecting the particle size evolution because of the collisions among vapor species in reaction field. Therefore, the AuNP size variation with the H2 volume ratio was discussed from the perspective of the etching rate of the Au wire at each H2 volume ratio.

  16. Diameter control of gold nanoparticles synthesized in gas phase using atmospheric-pressure H2/Ar plasma jet and gold wire as the nanoparticle source: Control by varying the H2/Ar mixture ratio

    Directory of Open Access Journals (Sweden)

    Yoshiki Shimizu

    2017-01-01

    Full Text Available This report describes diameter control of gold nanoparticles (AuNPs during synthesis using an atmospheric-pressure H2/Ar plasma jet drive with pulse-modulated ultrahigh frequency, employing Au wire as the NP source material. During this process, where most of the AuNPs are regarded as formed through condensation from Au vapor derived by the Au wire etching, the mean diameter varied in the approximate range of 2–12 nm with H2 volume ratios up to 3.9%. In plasma diagnostics, results showed that the H2 volume ratio influences the plasma discharge behaviour, which affects the heat flux density flowed into the Au wire, and the atomic hydrogen concentration in the plasma. Both seemed to influence the etching rate of the Au wire per unit area, which is directly related to the concentration of Au vapor in the plasma. The concentration is one factor affecting the particle size evolution because of the collisions among vapor species in reaction field. Therefore, the AuNP size variation with the H2 volume ratio was discussed from the perspective of the etching rate of the Au wire at each H2 volume ratio.

  17. Discussion on the Ground Source Heat Pump Pechnology%浅谈地源热泵技术

    Institute of Scientific and Technical Information of China (English)

    齐游洋; 辛立民

    2015-01-01

    The ground source heat pump system is the use of shallow geothermal heating and cooling system can be used in a new type of energy. Efficient use of ground source heat pump technology offers cold energy to the building, in order to meet a variety of building functions, for easy, fast and comfortable en-vironment is the goal of ground source heat pump technology. In order to solve the problem of building energy consumption is too serious, the best way is to research more new and renewable en-ergy, so as to achieve the purpose of building energy efficiency. This paper details the principle of ground source heat pump tech-nology, as well as ground-source heat pump classification and characteristics, and prospects of its development prospects.%地源热泵系统是利用浅层地能进行供热制冷的新型能源所使用的系统。高效利用地源热泵技术提供给建筑的冷热能量,以满足建筑的各种使用功能,实现方便、快捷、舒适的环境,是地源热泵技术实现的目标。为了解决建筑耗能过于严重的问题,最好的办法就是更多地去研究新的可再生能源,从而达到建筑节能的目的。本文主要详细阐述了地源热泵技术的原理,以及地源热泵的分类及其特点,并展望其发展前景。

  18. Contamination source review for Building E5032, Edgewood Area, Aberdeen Proving Ground, Maryland

    Energy Technology Data Exchange (ETDEWEB)

    Booher, M.N.; O`Reilly, D.P.; Smits, M.P. [and others

    1995-09-01

    This report by Argonne National Laboratory (ANL) documents results of a contamination source review of Building E5032 at the Aberdeen Proving Ground (APG) in Maryland. The review included a historical records search, physical inspection, photographic documentation, geophysical investigation, and review of available records regarding underground storage tanks associated with Building E5032. The field investigations were performed by ANL during 1994 and 1995. Building E5032 (APG designation), originally known as Building 99, is located at the northwest comer of the intersection of Hoadley Road and Magnolia Road in the Edgewood Area of APG. It was constructed during World War I as an incendiary bomb filling plant and in 1920s and 1930s maintained as a filling facility. During World War II the building was a pilot plant for the development of a dry white phosphorus filling process. Since then the building has been used for white phosphorus filling pilot studies. Most of the dry filling methods were developed in Building E5032 between 1965 and 1970. Other filling operations in Building E5032 have included mustard during the period shortly after World War II and triethyl aluminum (TEA) during the late 1960s and early 1970s. During the World War II period, the building was connected to the sanitary sewer system with one large and at least one small interior sump. There are also seven sumps adjacent to the exterior of the building: two on the west elevation, four near the four bays on the south elevation, and one at the northeast corner of the building. All of these sumps are connected with the chemical sewer system and received most, if not all, of the production operation wastewater. The discharge from this system was released into the east branch of Canal Creek; the discharge pipe was located southeast of Building E5032. There are no records indicating the use of Building E5032 after 1974, and it is assumed that the building has been out of service since that time.

  19. Greenhouse Gas Emissions from Ground Level Area Sources in Dairy and Cattle Feedyard Operations

    Directory of Open Access Journals (Sweden)

    Calvin B. Parnell

    2011-08-01

    Full Text Available A protocol that consisted of an isolation flux chamber and a portable gas chromatograph was used to directly quantify greenhouse gas (GHG emissions at a dairy and a feedyard operation in the Texas Panhandle. Field sampling campaigns were performed 5 consecutive days only during daylight hours from 9:00 am to 7:00 pm each day. The objective of this research was to quantify and compare GHG emission rates (ERs from ground level area sources (GLAS at dairy and cattle feedyard operations during the summer. A total of 74 air samples using flux chamber were collected from the barn (manure lane and bedding area, loafing pen, open lot, settling basin, lagoons, and compost pile within the dairy operation. For the cattle feedyard, a total of 87 air samples were collected from four corner pens of a large feedlot, runoff holding pond, and compost pile. Three primary GHGs (methane, carbon dioxide, and nitrous oxide were measured and quantified from both operations. The aggregate estimated ERs for CH4, CO2, and N2O were 836, 5573, 3.4 g hd−1 d−1 (collectively 27.5 kg carbon dioxide equivalent (CO2e hd−1 d−1, respectively, at the dairy operation. The aggregate ERs for CH4, CO2, and N2O were 3.8, 1399, 0.68 g hd−1 d−1 (1.7 kg CO2e hd−1 d−1, respectively, from the feedyard. The estimated USEPA GHG ERs were about 13.2 and 1.16 kg CO2e hd−1 d−1, respectively, for dairy and feedyard operations. Aggregate CH4, CO2 and N2O ERs at the dairy facility were about 219, 4 and 5 times higher, respectively, than those at the feedyard. At the dairy, average CH4 ERs estimated from the settling basin, primary and secondary lagoons were significantly higher than those from the other GLAS, contributing about 98% of the aggregate CH4 emission. The runoff holding pond and pen surface of the feedyard contributed about 99% of the aggregate CH4 emission. Average CO2 and N2O ERs estimated from the pen surface area were significantly higher than those estimated from

  20. Plasma chemistry in wire chambers

    Energy Technology Data Exchange (ETDEWEB)

    Wise, J.

    1990-05-01

    The phenomenology of wire chamber aging is discussed and fundamentals of proportional counters are presented. Free-radical polymerization and plasma polymerization are discussed. The chemistry of wire aging is reviewed. Similarities between wire chamber plasma (>1 atm dc-discharge) and low-pressure rf-discharge plasmas, which have been more widely studied, are suggested. Construction and use of a system to allow study of the plasma reactions occurring in wire chambers is reported. A proportional tube irradiated by an {sup 55}Fe source is used as a model wire chamber. Condensable species in the proportional tube effluent are concentrated in a cryotrap and analyzed by gas chromatography/mass spectrometry. Several different wire chamber gases (methane, argon/methane, ethane, argon/ethane, propane, argon/isobutane) are tested and their reaction products qualitatively identified. For all gases tested except those containing methane, use of hygroscopic filters to remove trace water and oxygen contaminants from the gas resulted in an increase in the average molecular weight of the products, consistent with results from low-pressure rf-discharge plasmas. It is suggested that because water and oxygen inhibit polymer growth in the gas phase that they may also reduce polymer deposition in proportional tubes and therefore retard wire aging processes. Mechanistic implications of the plasma reactions of hydrocarbons with oxygen are suggested. Unresolved issues in this work and proposals for further study are discussed.

  1. Optimum bleeding rate of open loop ground source heat pump systems determined by hydrogeological modeling in Korea

    Science.gov (United States)

    Jeon, W. H.; Kim, N.; Lee, J. Y.

    2014-12-01

    This study aims to evaluate the influence of open loop ground source heat pump systems operation on hydrological conditions of aquifer. Test bed is located in Chuncheon, Korea. The step drawdown test was conducted in five stages for 300 minutes. The variation of groundwater levels by open loop ground source heat pump systems operation was estimated using Visual MODFLOW. Transmissivity ranged from 2.02×10-4 to 9.36×10-4, and storage coefficient ranged from 0.00067 to 0.021. The amount of optimum bleeding was calculated to be 240 m3/day. When bleeding will be 50, 90, 240 and 450 m3/day for 5 years, groundwater levels may decrease 1.84, 3.31, 8.89 and 17.0 m, respectively. If the amount of bleeding is 50 m3/day, the influence of bleeding will not reach the boundary regions of the Soyang River after 5 years. Regarding the open loop ground source heat pump system installed at the test bed, the amount of optimum bleeding in accordance with the stand are proposed by the government is 90 m3/day, which is 20% of the 450 m3/day circulation quantity of the system. However, if continuous bleeding of more than 90 m3/day occurs, then the radius of influence is expected to reach the boundary regions of the Soyang River after 5 years. These results indicate that amount of optimum bleeding differ in each open loop ground soured heat pump system. Therefore, the debate for the amount of optimum bleeding in open loop ground source heat pump systems is demanded. This work is supported by the Energy Efficiency and Resources of the Korea Institute of Energy Technology Evaluation and Planning (KETEP) grant funded by the Korea government Ministry of Knowledge Economy (No.20123040110010).

  2. Ground Fault Overvoltage With Inverter-Interfaced Distributed Energy Resources

    Energy Technology Data Exchange (ETDEWEB)

    Ropp, Michael; Hoke, Anderson; Chakraborty, Sudipta; Schutz, Dustin; Mouw, Chris; Nelson, Austin; McCarty, Michael; Wang, Trudie; Sorenson, Adam

    2017-04-01

    Ground Fault Overvoltage can occur in situations in which a four-wire distribution circuit is energized by an ungrounded voltage source during a single phase to ground fault. The phenomenon is well-documented with ungrounded synchronous machines, but there is considerable discussion about whether inverters cause this phenomenon, and consequently whether inverters require effective grounding. This paper examines the overvoltages that can be supported by inverters during single phase to ground faults via theory, simulation and experiment, identifies the relevant physical mechanisms, quantifies expected levels of overvoltage, and makes recommendations for optimal mitigation.

  3. OPGW光纤复合架空地线异常发热现场测量分析及仿真%On-site Measurement Based Analysis and Simulation of Abnormal Heating of Optical Fiber Composite Overhead Ground Wires

    Institute of Scientific and Technical Information of China (English)

    彭向阳; 刘毅刚; 张穗强

    2012-01-01

    In allusion to the phenomenon of abnormal heating at the joint where the optical fiber composite overhead ground wire (OPGW) is connected to the truss of substation, the on-site measurement of the induced current and voltage of the grounding circuit of OPGW was performed, and based on the measured results the reason causing the abnormal heating was analyzed. Analysis results showed that the bad contact of OPGW with the truss made the grounding current of OPGW transferring to the circuit of tensional joint and the heating power was larger and concentrated. On this basis the simulation research on induced current of OPGW and heating power are conducted, and simulation results basically conform to the measured data. Research results show that power flow of transmission line, tower grounding resistance and contact resistance of the joint where OPGW is connected to the truss differently influence on the shunt of grounding current of OPGW and the heating power.%针对光纤复合架空地线foptical fiber composite overhead ground wire,OPGW)在变电站构架连接处的异常发热问题,对其接地回路感应电流、电压进行现场实测,分析出异常发热原因是构架处OPGW主接地不良导致接地电流转移至耐张连接回路,且发热功率较大及较集中。据此进一步开展OPGW感应电流、发热功率的仿真研究,仿真与实测数据基本吻合。研究表明线路负荷电流、杆塔接地电阻以及OPGW与构架连接接触电阻对OPGW接地回路分流及发热功率存在不同程度的影响。

  4. Performance of water source heat pump system using high-density polyethylene tube heat exchanger wound with square copper wire

    Directory of Open Access Journals (Sweden)

    Xin Wen Zhang

    2015-07-01

    Full Text Available Surface water source heat pump system is an energy-efficient heat pump system. Surface water heat exchanger is an important part of heat pump system that can affect the performance of the system. In order to enhance the performance of the system, the overall heat transfer coefficient (U value of the water exchanger using a 32A square copper coiled high-density polyethylene tube was researched. Comparative experiments were conducted between the performance of the coiled high-density polyethylene tube and the 32A smooth high-density polyethylene tube. At the same time, the coefficient of performance of the heat pump was investigated. According to the result, the U value of the coiled tube was 18% higher than that of the smooth tube in natural convection and 19% higher in forced convection. The coefficient of performance of the heat pump with the coiled tube is higher than that with the smooth tube. The economic evaluation of the coiled tube was also investigated.

  5. Annual investigation of vertical type ground source heat pump system performance on a wall heating and cooling system in Istanbul

    Energy Technology Data Exchange (ETDEWEB)

    Akbulut, U.; Yoru, Y.; Kincay, O. [Department of Mechanical Engineering, Yildiz Technical University (Turkey)], email: akbulutugur@yahoo.com, email: yilmazyoru@gmail.com, email: okincay@yildiz.edu.tr

    2011-07-01

    Wall heating and cooling systems (WHCS) are equipped with heating serpentines or panels for water circulation. These systems operate in a low temperature range so they are preferable to other, conventional systems. Furthermore, when these systems are connected to a ground source heat pump (GSHP) system, energy performance and thermal comfort are further enhanced. The purpose of this paper is to report the results of an annual inspection done on a vertical type ground-coupled heat pump systems (V-GSHP) WHCS in Istanbul and present the results. The performance data from the Yildiz Renewable Energy House at Davutpasa Campus of Yildiz Technical University, Istanbul, Turkey, during the year 2010 were collected and analyzed. The conclusions drawn from the inspection and analysis were listed in this paper. Using renewable energy sources effectively will bring both economic and environmental benefits and it is hoped that the use of these energy efficient WHCS systems will become widespread.

  6. Optimization of systems with the combination of ground-source heat pump and solar collectors in dwellings

    DEFF Research Database (Denmark)

    Kjellsson, Elisabeth; Hellström, Göran; Perers, Bengt

    2010-01-01

    The use of ground-source heat pumps for heating and domestic hot water in dwellings is common in Sweden. The combination with solar collectors has been introduced to reduce the electricity demand in the system. In order to analyze different systems with combinations of solar collectors and ground......-source heat pumps, computer simulations have been carried out with the simulation program TRNSYS. Large differences were found between the system alternatives. The optimal design is when solar heat produces domestic hot water during summertime and recharges the borehole during wintertime. The advantage...... is related to the rate of heat extraction from the borehole as well as the overall design of the system. The demand of electricity may increase with solar recharging, because of the increased operating time of the circulation pumps. Another advantage with solar heat in combination with heat pumps is when...

  7. Application Study on Ground Source Heat Pump System%地源热泵系统的应用研究

    Institute of Scientific and Technical Information of China (English)

    李异; 石新会

    2011-01-01

    为了减少一次性能源的使用和对环境的污染,本文以陕西安康市某综合建筑为例,通过对比地源热泵系统和常规空调系统的初投资和运行费用,论证了地源热泵系统的经济性.%In order to reduce the pollution to environment of the primary energy, a packaged building in Ankang is taken for example, and this paper proves the ground-source heal pumps economy by comparing the initial investment and operating costs of ground-source heat pumps system and conventional air conditioning systems.

  8. Ground-Source Heat Pumps. Overview of Market Status, Barriers to Adoption, and Options for Overcoming Barriers

    Energy Technology Data Exchange (ETDEWEB)

    Goetzler, William [Navigant Consulting, Inc., Chicago, IL (United States); Zogg, Robert [Navigant Consulting, Inc., Chicago, IL (United States); Lisle, Heather [Navigant Consulting, Inc., Chicago, IL (United States); Burgos, Javier [Navigant Consulting, Inc., Chicago, IL (United States)

    2009-02-03

    February 2009 final report submitted to DOE by Navigant Consulting, Inc. This report summarizes the status of ground-source heat pump (GSHP) technology and market penetration globally, estimates the energy saving potential of GSHPs in the U.S., identifies key market barriers that are inhibiting wider market adoption of GSHPs, and recommends initiatives that can be implemented or facilitated by the DOE to accelerate market adoption.

  9. An In-Depth Look at Ground Source Heat Pumps and Other Electric Loads in Two GreenMax Homes

    Energy Technology Data Exchange (ETDEWEB)

    Puttagunta, Srikanth [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States); Shapiro, Carl [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States)

    2012-04-01

    Building America research team Consortium for Advanced Residential Buildings (CARB) partnered with WPPI Energy to answer key research questions on in-field performance of ground-source heat pumps and lighting, appliance, and miscellaneous loads (LAMELs) through extensive field monitoring at two WPPI GreenMax demonstration homes in Wisconsin. These two test home evaluations provided valuable data on the true in-field performance of various building mechanical systems and LAMELs.

  10. Vibrating wires for beam diagnostics

    CERN Document Server

    Arutunian, S G; Wittenburg, Kay

    2015-01-01

    A new approach to the technique of scanning by wires is developed. Novelty of the method is that the wire heating quantity is used as a source of information about the number of interacting particles. To increase the accuracy and sensitivity of measurements the wire heating measurement is regenerated as a change of wire natural oscillations frequency. By the rigid fixing of the wire ends on the base an unprecedented sensitivity of the frequency to the temperature and to the corresponding flux of colliding particles. The range of used frequencies (tens of kHz) and speed of processes of heat transfer limit the speed characteristics of proposed scanning method, however, the high sensitivity make it a perspective one for investigation of beam halo and weak beam scanning. Traditional beam profile monitors generally focus on the beam core and loose sensitivity in the halo region where a large dynamic range of detection is necessary. The scanning by a vibrating wire can be also successfully used in profiling and det...

  11. An Earthquake Source Ontology for Seismic Hazard Analysis and Ground Motion Simulation

    Science.gov (United States)

    Zechar, J. D.; Jordan, T. H.; Gil, Y.; Ratnakar, V.

    2005-12-01

    Representation of the earthquake source is an important element in seismic hazard analysis and earthquake simulations. Source models span a range of conceptual complexity - from simple time-independent point sources to extended fault slip distributions. Further computational complexity arises because the seismological community has established so many source description formats and variations thereof; what this means is that conceptually equivalent source models are often expressed in different ways. Despite the resultant practical difficulties, there exists a rich semantic vocabulary for working with earthquake sources. For these reasons, we feel it is appropriate to create a semantic model of earthquake sources using an ontology, a computer science tool from the field of knowledge representation. Unlike the domain of most ontology work to date, earthquake sources can be described by a very precise mathematical framework. Another uniqueness associated with developing such an ontology is that earthquake sources are often used as computational objects. A seismologist generally wants more than to simply construct a source and have it be well-formed and properly described; additionally, the source will be used for performing calculations. Representation and manipulation of complex mathematical objects presents a challenge to the ontology development community. In order to enable simulations involving many different types of source models, we have completed preliminary development of a seismic point source ontology. The use of an ontology to represent knowledge provides machine interpretability and the ability to validate logical consistency and completeness. Our ontology, encoded using the OWL Web Ontology Language - a standard from the World Wide Web Consortium, contains the conceptual definitions and relationships necessary for source translation services. For example, specification of strike, dip, rake, and seismic moment will automatically translate into a double

  12. Distinguishing sources of ground water recharge by using delta2H and delta18O.

    Science.gov (United States)

    Blasch, Kyle W; Bryson, Jeannie R

    2007-01-01

    Stable isotope values of hydrogen and oxygen from precipitation and ground water samples were compared by using a volumetrically based mixing equation and stable isotope gradient to estimate the season and location of recharge in four basins. Stable isotopes were sampled at 11 precipitation sites of differing elevation during a 2-year period to quantify seasonal stable isotope contributions as a function of elevation. Supplemental stable isotope data collected by the International Atomic Energy Association during a 14-year period were used to reduce annual variability of the mean seasonal stable isotope data. The stable isotope elevation relationships and local precipitation elevation relationships were combined by using a digital elevation model to calculate the total volumetric contribution of water and stable isotope values as a function of elevation within the basins. The results of these precipitation calculations were compared to measured ground water stable isotope values at the major discharge points near the terminus of the basins. Volumetric precipitation contributions to recharge were adjusted to isolate contributing elevations. This procedure provides an improved representation of recharge contributions within the basins over conventional stable isotope methods. Stable isotope values from wells and springs at the terminus of each basin were used to infer the elevations of precipitation important for recharge of the regional ground water flow system. Ancillary climatic, geologic, and stable isotope values were used to further constrain the location where precipitation is entering the ground water flow system.

  13. 30 CFR 75.1003 - Insulation of trolley wires, trolley feeder wires and bare signal wires; guarding of trolley...

    Science.gov (United States)

    2010-07-01

    ... wires and bare signal wires; guarding of trolley wires and trolley feeder wires. 75.1003 Section 75.1003... Insulation of trolley wires, trolley feeder wires and bare signal wires; guarding of trolley wires and trolley feeder wires. Trolley wires, trolley feeder wires, and bare signal wires shall be insulated...

  14. Wiring regulations in brief

    CERN Document Server

    Tricker, Ray

    2012-01-01

    Tired of trawling through the Wiring Regs?Perplexed by Part P?Confused by cables, conductors and circuits?Then look no further! This handy guide provides an on-the-job reference source for Electricians, Designers, Service Engineers, Inspectors, Builders, Students, DIY enthusiastsTopic-based chapters link areas of working practice - such as cables, installations, testing and inspection, special locations - with the specifics of the Regulations themselves. This allows quick and easy identification of the official requirements relating to the situati

  15. Behavior of peak values and spectral ordinates of near-source strong ground motion over the smart 1 array

    Energy Technology Data Exchange (ETDEWEB)

    Niazi, M.

    1990-06-01

    The array recordings are used to investigate several important properties of the seismic ground motions themselves. The results reported here address the question of the variability of the peak vertical and horizontal accelerations, velocities and displacements. Statistical treatment of the variability is feasible when ground motions are recorded, as in SMART 1, at a group of stations within a limited distance. The three rings of the SMART 1 array have radii of 200 m, 1 km and 2 km. Since it became operational in September 1980, it has recorded accelerations up to 0.33g and 0.34g on the horizontal and vertical components, respectively. At present there are over 3,000 accelerograms from 53 local earthquakes available. From the set of observations, 12 earthquakes have been selected providing more than 700 accelerograms for analysis and statistical treatment. Nonlinear regression procedure are used to fit the peak values to an attenuation form which has as parameters, earthquake magnitude and source-to-site distance. Spectral information on ground motion is included; correlations are made between spectral ordinate values at 23 discrete frequencies in the range of engineering interest. Among the notable results is the finding that the ratio of the vertical to horizontal response spectral ordinates is less than the often used value of 2/3 for periods longer than about 0.2 second, and also for all frequencies at distances greater than 30 km from the source.

  16. Local point sources that affect ground-water quality in the East Meadow area, Long Island, New York

    Science.gov (United States)

    Heisig, Paul M.

    1994-01-01

    The extent and chemical characteristics of ground water affected by three local point sources--a stormwater basin, uncovered road-salt-storage piles, and an abandoned sewage-treatment plant--were delineated during a 3-year study of the chemical characteristics and migration of a body of reclaimed wastewater that was applied to the watertable aquifer during recharge experiments from October 1982 through January 1984 in East Meadow. The timing, magnitude, and chemical quality of recharge from these point sources is highly variable, and all sources have the potential to skew determinations of the quality of ambient ground-water and of the reclaimed-wastewater plume if they are not taken into account. Ground water affected by recharge from the stormwater basin is characterized by low concentrations of nitrate + nitrite (less than 5 mg/L [milligrams per liter] as N) and sulfate (less than 40 mg/L) and is almost entirely within the upper glacial aquifer. The plume derived from road-salt piles is narrow, has high concentrations of chloride (greater than 50 mg/L) and sodium (greater than 75 mg/L), and also is limited to the upper glacial aquifer. The sodium, in high concentrations, could react with aquifer material and exchange for sorbed cations such as calcium, potassium, and magnesium. Water affected by secondary-treated sewage from the abandoned treatment plant extends 152 feet below land surface into the upper part of the Magothy aquifer and longitudinally beyond the southern edge of the study area, 7,750 feet south of the recharge site. Ground water affected by secondary-treated sewage within the study area typically contains elevated concentrations of reactive chemical constituents, such as potassium and ammonium, and low concentrations of dissolved oxygen. Conservative or minimally reactive constituents such as chloride and sodium have been transported out of the study area in the upper glacial aquifer and the intermediate (transitional) zone but remain in the less

  17. The role of topography and lateral velocity heterogeneities on near-source scattering and ground-motion variability

    KAUST Repository

    Imperatori, W.

    2015-07-28

    The scattering of seismic waves travelling in the Earth is not only caused by random velocity heterogeneity but also by surface topography. Both factors are known to strongly affect ground-motion complexity even at relatively short distance from the source. In this study, we simulate ground motion with a 3-D finite-difference wave propagation solver in the 0–5 Hz frequency band using three topography models representative of the Swiss alpine region and realistic heterogeneous media characterized by the Von Karman correlation functions. Subsequently, we analyse and quantify the characteristics of the scattered wavefield in the near-source region. Our study shows that both topography and velocity heterogeneity scattering may excite large coda waves of comparable relative amplitude, especially at around 1 Hz, although large variability in space may occur. Using the single scattering model, we estimate average QC values in the range 20–30 at 1 Hz, 36–54 at 1.5 Hz and 62–109 at 3 Hz for constant background velocity models with no intrinsic attenuation. In principle, envelopes of topography-scattered seismic waves can be qualitatively predicted by theoretical back-scattering models, while forward- or hybrid-scattering models better reproduce the effects of random velocity heterogeneity on the wavefield. This is because continuous multiple scattering caused by small-scale velocity perturbations leads to more gentle coda decay and envelope broadening, while topography abruptly scatters the wavefield once it impinges the free surface. The large impedance contrast also results in more efficient mode mixing. However, the introduction of realistic low-velocity layers near the free surface increases the complexity of ground motion dramatically and indicates that the role of topography in elastic waves scattering can be relevant especially in proximity of the source. Long-period surface waves can form most of the late coda, especially when intrinsic attenuation is taken

  18. Challenges in seismic hazard assessment: Analyses of ground motion modelling and seismotectonic sources

    OpenAIRE

    Sørensen, Mathilde Bøttger

    2006-01-01

    Seismic hazard assessment has an important societal impact in describing levels of ground motions to be expected in a given region in the future. Challenges in seismic hazard assessment are closely associated with the fact that different regions, due to their differences in seismotectonics setting (and hence in earthquake occurrence) as well as socioeconomic conditions, require different and innovative approaches. One of the most important aspects in this regard is the seismici...

  19. Recovery Act: Tennessee Energy Efficient Schools Initiative Ground Source Heat Pump Program

    Energy Technology Data Exchange (ETDEWEB)

    Townsend, Terry [Townsend Engineering, Inc., Davenport, IA (United States); Slusher, Scott [Townsend Engineering, Inc., Davenport, IA (United States)

    2017-04-24

    The Tennessee Energy Efficient Schools Initiative (EESI) Hybrid-Water Source Heat Pump (HY-GSHP) Program sought to provide installation costs and operation costs for different Hybrid water source heat pump systems’ configurations so that other State of Tennessee School Districts will have a resource for comparison purposes if considering a geothermal system.

  20. Source Rupture Process and Near-Fault Ground Motions of the 2016 Kumamoto Earthquake Sequence Estimated from Strong Motion Data

    Science.gov (United States)

    Asano, K.; Iwata, T.

    2016-12-01

    The 2016 Kumamoto earthquake sequence started with an MJMA 6.5 foreshock on April 14, 2016 occurring along the northern part of the Hinagu fault, central Kyushu, Japan, and the MJMA 7.3 mainshock occurred just 28 h after the foreshock. Both events brought severe ground motions to the near-source region. We analyzed the kinematic source rupture processes of the foreshock and mainshock by the multiple time window linear waveform inversion using strong motion data (e.g., Hartzell and Heaton, 1983). The foreshock (Mw 6.1) was characterized by right-lateral strike-slip occurring on a nearly vertical fault plane along the northern part of the Hinagu fault, and it had two large-slip areas: one near the hypocenter and another at a shallow depth. These two large-slip areas mainly contribute ground motions in the near-source area. For the analysis of the mainshock, we assumed a fault geometry changing strike and dip angles along the Hinagu and Futagawa faults in accordance with the surface ruptures mapped by emergency field surveys (Kumahara et al., 2016). We assigned point sources densely with an interval of 0.2 km on the assumed fault planes in order to reproduce appropriately near-fault ground motions, and estimated spatiotemporal slip history, which was discretized with an interval of 1.8 km on the fault planes. The estimated source model reveals that the rupture of the mainshock started at a northwest-dipping fault plane along the Hinagu fault, which is close to the vertical fault plane of the foreshock, and almost continuously propagated across the junction of the Hinagu and Futagawa faults. Then the rupture propagated northeastward along the Futagawa fault, and stopped to rupture in the western part of the Aso caldera. The significant slip with 3-5 m were observed on the Futagawa fault, and shallowest part has slip ranging from 1 to 2 m. We also tried to reproduce ground motions observed at some near-fault strong motion stations, which recorded significant coseismic

  1. Improved finite-source inversion through joint measurements of rotational and translational ground motions: a numerical study

    Science.gov (United States)

    Reinwald, Michael; Bernauer, Moritz; Igel, Heiner; Donner, Stefanie

    2016-10-01

    With the prospects of seismic equipment being able to measure rotational ground motions in a wide frequency and amplitude range in the near future, we engage in the question of how this type of ground motion observation can be used to solve the seismic source inverse problem. In this paper, we focus on the question of whether finite-source inversion can benefit from additional observations of rotational motion. Keeping the overall number of traces constant, we compare observations from a surface seismic network with 44 three-component translational sensors (classic seismometers) with those obtained with 22 six-component sensors (with additional three-component rotational motions). Synthetic seismograms are calculated for known finite-source properties. The corresponding inverse problem is posed in a probabilistic way using the Shannon information content to measure how the observations constrain the seismic source properties. We minimize the influence of the source receiver geometry around the fault by statistically analyzing six-component inversions with a random distribution of receivers. Since our previous results are achieved with a regular spacing of the receivers, we try to answer the question of whether the results are dependent on the spatial distribution of the receivers. The results show that with the six-component subnetworks, kinematic source inversions for source properties (such as rupture velocity, rise time, and slip amplitudes) are not only equally successful (even that would be beneficial because of the substantially reduced logistics installing half the sensors) but also statistically inversions for some source properties are almost always improved. This can be attributed to the fact that the (in particular vertical) gradient information is contained in the additional motion components. We compare these effects for strike-slip and normal-faulting type sources and confirm that the increase in inversion quality for kinematic source parameters is

  2. Vibration measurements of a wire scanner - Experimental setup and models

    Science.gov (United States)

    Herranz, Juan; Barjau, Ana; Dehning, Bernd

    2016-03-01

    In the next years the luminosity of the LHC will be significantly increased. This will require a much higher accuracy of beam profile measurement than actually achievable by the current wire scanner. The new performance demands a wire travelling speed up to 20 m s-1 and a position measurement accuracy of the order of 1 μm. The vibrations of the mechanical parts of the system and particularly the vibrations of the thin carbon wire have been identified as the major error sources of wire position uncertainty. Therefore the understanding of the wire vibrations has been given high priority for the design and operation of the new device. This article presents a new strategy to measure the wire vibrations based on the piezoresistive effect of the wire itself. An electronic readout system based on a Wheatstone bridge is used to measure the variation of the carbon wire resistance, which is directly proportional to the wire elongation caused by the oscillations.

  3. Impacts of climate warming on the frozen ground and eco-hydrology in the Yellow River source region, China.

    Science.gov (United States)

    Qin, Yue; Yang, Dawen; Gao, Bing; Wang, Taihua; Chen, Jinsong; Chen, Yun; Wang, Yuhan; Zheng, Guanheng

    2017-12-15

    The Yellow River source region is located in the transition region between permafrost and seasonally frozen ground on the northeastern Qinghai-Tibet Plateau. The region has experienced severe climate change, especially air temperature increases, in past decades. In this study, we employed a geomorphology-based eco-hydrological model (GBEHM) to assess the impacts of climate change on the frozen ground and eco-hydrological processes in the region. Based on a long-term simulation from 1981 to 2015, we found that the areal mean maximum thickness of seasonally frozen ground ranged from 1.1-1.8m and decreased by 1.2cm per year. Additionally, the ratio of the permafrost area to the total area decreased by 1.1% per year. These decreasing trends are faster than the average in China because the study area is on the sensitive margin of the Qinghai-Tibet Plateau. The annual runoff exhibited variations similar to those of the annual precipitation (R(2)=0.85), although the annual evapotranspiration (ET) exhibited an increasing trend (14.3mm/10a) similar to that of the annual mean air temperature (0.66°C/10a). The runoff coefficient (annual runoff divided by annual precipitation) displayed a decreasing trend because of the increasing ET, and the vegetation responses to climate warming and permafrost degradation were manifested as increases in the leaf area index (LAI) and ET at the start of the growing season. Furthermore, the results showed that changes to the frozen ground depth affected vegetation growth. Notably, a rapid decrease in the frozen ground depth (hydrological processes in the headwater area of the Yellow River have changed because of permafrost degradation, and these changes could further influence the water resources availability in the middle and lower reaches of the basin. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. A Single Phase Doubly Grounded Semi-Z-Source Inverter for Photovoltaic (PV Systems with Maximum Power Point Tracking (MPPT

    Directory of Open Access Journals (Sweden)

    Tofael Ahmed

    2014-06-01

    Full Text Available In this paper, a single phase doubly grounded semi-Z-source inverter with maximum power point tracking (MPPT is proposed for photovoltaic (PV systems. This proposed system utilizes a single-ended primary inductor (SEPIC converter as DC-DC converter to implement the MPPT algorithm for tracking the maximum power from a PV array and a single phase semi-Z-source inverter for integrating the PV with AC power utilities. The MPPT controller utilizes a fast-converging algorithm to track the maximum power point (MPP and the semi-Z-source inverter utilizes a nonlinear SPWM to produce sinusoidal voltage at the output. The proposed system is able to track the MPP of PV arrays and produce an AC voltage at its output by utilizing only three switches. Experimental results show that the fast-converging MPPT algorithm has fast tracking response with appreciable MPP efficiency. In addition, the inverter shows the minimization of common mode leakage current with its ground sharing feature and reduction of the THD as well as DC current components at the output during DC-AC conversion.

  5. Thermal Aware Floorplanning Incorporating Temperature Dependent Wire Delay Estimation

    DEFF Research Database (Denmark)

    Winther, AndreasThor; Liu, Wei; Nannarelli, Alberto

    2015-01-01

    Temperature has a negative impact on metal resistance and thus wire delay. In state-of-the-art VLSI circuits, large thermal gradients usually exist due to the uneven distribution of heat sources. The difference in wire temperature can lead to performance mismatch because wires of the same length ...

  6. Prediction of broadband ground-motion time histories: Hybrid low/high-frequency method with correlated random source parameters

    Science.gov (United States)

    Liu, P.; Archuleta, R.J.; Hartzell, S.H.

    2006-01-01

    We present a new method for calculating broadband time histories of ground motion based on a hybrid low-frequency/high-frequency approach with correlated source parameters. Using a finite-difference method we calculate low- frequency synthetics (3D velocity structure. We also compute broadband synthetics in a 1D velocity model using a frequency-wavenumber method. The low frequencies from the 3D calculation are combined with the high frequencies from the 1D calculation by using matched filtering at a crossover frequency of 1 Hz. The source description, common to both the 1D and 3D synthetics, is based on correlated random distributions for the slip amplitude, rupture velocity, and rise time on the fault. This source description allows for the specification of source parameters independent of any a priori inversion results. In our broadband modeling we include correlation between slip amplitude, rupture velocity, and rise time, as suggested by dynamic fault modeling. The method of using correlated random source parameters is flexible and can be easily modified to adjust to our changing understanding of earthquake ruptures. A realistic attenuation model is common to both the 3D and 1D calculations that form the low- and high-frequency components of the broadband synthetics. The value of Q is a function of the local shear-wave velocity. To produce more accurate high-frequency amplitudes and durations, the 1D synthetics are corrected with a randomized, frequency-dependent radiation pattern. The 1D synthetics are further corrected for local site and nonlinear soil effects by using a 1D nonlinear propagation code and generic velocity structure appropriate for the site’s National Earthquake Hazards Reduction Program (NEHRP) site classification. The entire procedure is validated by comparison with the 1994 Northridge, California, strong ground motion data set. The bias and error found here for response spectral acceleration are similar to the best results that have been

  7. Energy performance of a ventilation system for a block of apartments with a ground source heat pump as generation system

    Science.gov (United States)

    Lucchi, M.; Lorenzini, M.; Valdiserri, P.

    2017-01-01

    This work presents a numerical simulation of the annual performance of two different systems: a traditional one composed by a gas boiler-chiller pair and one consisting of a ground source heat pump (GSHP) both coupled to two thermal storage tanks. The systems serve a bloc of flats located in northern Italy and are assessed over a typical weather year, covering both the heating and cooling seasons. The air handling unit (AHU) coupled with the GSHP exhibits excellent characteristics in terms of temperature control, and has high performance parameters (EER and COP), which make conduction costs about 30% lower than those estimated for the traditional plant.

  8. 地源热泵与混合式地源热泵应用对比分析%Comparative Analysis of Ground Source Heat Pumps and Hybrid Ground Source Heat Pump

    Institute of Scientific and Technical Information of China (English)

    陈正顺

    2014-01-01

    Ground Source Heat Pumps(GSHPs) and Hybrid Ground Source Heat Pumps(HGSHPs) in-stalled in several public buildings are compared. The annual energy consumption of buildings are simulated respectively, taking selection calculation of GSHPs and HGSHPs, as well as the initial investment, annual operating costs and the comprehensive fee of two programs.%对合肥几种常见公共建筑已完全使用地埋管换热器的地源热泵系统与混合式地源热泵系统进行了比较。分别对各类型建筑进行了全年能耗模拟,对地源热泵、混合式地源热泵系统进行了选型计算,并对比了两种方案的初投资、年运行费用、年综合费用。

  9. Ground-based Observations of the Solar Sources of Space Weather (Invited Review)

    CERN Document Server

    Veronig, Astrid M

    2016-01-01

    Monitoring of the Sun and its activity is a task of growing importance in the frame of space weather research and awareness. Major space weather disturbances at Earth have their origin in energetic outbursts from the Sun: solar flares, coronal mass ejections and associated solar energetic particles. In this review we discuss the importance and complementarity of ground-based and space-based observations for space weather studies. The main focus is drawn on ground-based observations in the visible range of the spectrum, in particular in the diagnostically manifold H$\\alpha$ spectral line, which enables us to detect and study solar flares, filaments, filament eruptions, and Moreton waves. Existing H$\\alpha$ networks such as the GONG and the Global High-Resolution H$\\alpha$ Network are discussed. As an example of solar observations from space weather research to operations, we present the system of real-time detection of H$\\alpha$ flares and filaments established at Kanzelh\\"ohe Observatory (KSO; Austria) in the...

  10. The contributions of high- and low altitude emission sources to the near ground concentrations of air pollutants

    Science.gov (United States)

    Đorđević, Dragana S.; Šolević, Tatjana M.

    2008-02-01

    The scale of transport through the atmosphere depends on the effective height of an emission source, the meteorological conditions and the physico-chemical characteristics of the pollutants. Atmospheric surface temperature inversions play a significant role in the problem of air pollution since their upper edge acts as a natural barrier to the vertical dispersion of pollutants. When the altitude of an emission source is lower than the edge of the boundary layer, the pollution remains below the upper edge and spreads by advection inside the lower layer towards the ground. However, if the altitude of the emission source is higher than the edge of the boundary layer, then the pollution spreads above the barrier. An analysis of a pollution episode during one month (August 2004) in an urban atmosphere of industrial city, using results of continuous monitoring of minute-by-minute fluctuations of the pollutants' concentrations, is presented. Region of a developed industrial town as a model was investigated. The investigated region is characterized by maximum number of surface temperature inversions during the nights in August and their furlough during the day time. With a combination of local meteorological information, that is the number of surface temperature inversions of the atmosphere, the results showed that the concentrations of pollutants originating from low altitude emission sources, e.g. organic pollutants, were higher at night. The near ground concentrations of SO 2, originating from high-(industrial stacks) and low altitude (traffic) sources, and the PM 10 originating from various sources i.e. from complex mechanisms of formation e.g. traffic emissions, SOA mechanisms and re-suspensions, were the same during the night and during the day. However, concentrations of NH 3 from high altitude sources (fertilizer plant) were higher during the day. Cluster Analysis and Principal Component Analysis showed associations of highest correlation between pollutants, which

  11. submitter Dynamical Models of a Wire Scanner

    CERN Document Server

    Barjau, Ana; Dehning, Bernd

    2016-01-01

    The accuracy of the beam profile measurements achievable by the current wire scanners at CERN is limited by the vibrations of their mechanical parts. In particular, the vibrations of the carbon wire represent the major source of wire position uncertainty which limits the beam profile measurement accuracy. In the coming years, due to the Large Hadron Collider (LHC) luminosity upgrade, a wire traveling speed up to 20 $m s^{−1}$ and a position measurement accuracy of the order of 1 μm will be required. A new wire scanner design based on the understanding of the wire vibration origin is therefore needed. We present the models developed to understand the main causes of the wire vibrations observed in an existing wire scanner. The development and tuning of those models are based on measurements and tests performed on that CERN proton synchrotron (PS) scanner. The final model for the (wire + fork) system has six degrees-of-freedom (DOF). The wire equations contain three different excitation terms: inertia...

  12. Unraveling the sources of ground level ozone in the Intermountain Western United States using Pb isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Christensen, John N. [Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Weiss-Penzias, Peter [University of California at Santa Cruz, Santa Cruz, CA (United States); Fine, Rebekka [University of Nevada, Reno, NV (United States); McDade, Charles E.; Trzepla, Krystyna [University of California at Davis, Crocker Nuclear Laboratory, Davis, CA (United States); Brown, Shaun T. [Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Gustin, Mae Sexauer [University of Nevada, Reno, NV (United States)

    2015-10-15

    Ozone as an atmospheric pollutant is largely produced by anthropogenic precursors and can significantly impact human and ecosystem health, and climate. The U.S. Environmental Protection Agency has recently proposed lowering the ozone standard from 75 ppbv (MDA8 = Maximum Daily 8-Hour Average) to between 65 and 70 ppbv. This will result in remote areas of the Intermountain West that includes many U.S. National Parks being out of compliance, despite a lack of significant local sources. We used Pb isotope fingerprinting and back-trajectory analysis to distinguish sources of imported ozone to Great Basin National Park in eastern Nevada. During discrete Chinese Pb events (> 1.1 ng/m{sup 3} & > 80% Asian Pb) trans-Pacific transported ozone was 5 ± 5.5 ppbv above 19 year averages for those dates. In contrast, concentrations during regional transport from the Los Angeles and Las Vegas areas were 15 ± 2 ppbv above the long-term averages, and those characterized by high-altitude transport 3 days prior to sampling were 19 ± 4 ppbv above. However, over the study period the contribution of trans-Pacific transported ozone increased at a rate of 0.8 ± 0.3 ppbv/year, suggesting that Asian inputs will exceed regional and high altitude sources by 2015–2020. All of these sources will impact regulatory compliance with a new ozone standard, given increasing global background. - Highlights: • Ozone can significantly impact human and ecosystem health and climate. • Pb isotopes and back-trajectory analysis were used to distinguish sources of O{sub 3}. • Baseline concentrations in the Western US are ~ 54 ppbv. • During discrete Asia events O{sub 3} increased by 5 ± 5.5 ppbv and during S CA events by 15 ± 2 ppbv. • Data indicate that Asian ozone inputs will exceed other sources by 2015–2020.

  13. Ground-based Observations of the Solar Sources of Space Weather

    Science.gov (United States)

    Veronig, A. M.; Pötzi, W.

    2016-04-01

    Monitoring of the Sun and its activity is a task of growing importance in the frame of space weather research and awareness. Major space weather disturbances at Earth have their origin in energetic outbursts from the Sun: solar flares, coronal mass ejections and associated solar energetic particles. In this review we discuss the importance and complementarity of ground-based and space-based observations for space weather studies. The main focus is drawn on ground-based observations in the visible range of the spectrum, in particular in the diagnostically manifold Hα spectral line, which enables us to detect and study solar flares, filaments (prominences), filament (prominence) eruptions, and Moreton waves. Existing Hα networks such as the GONG and the Global High-Resolution Hα Network are discussed. As an example of solar observations from space weather research to operations, we present the system of real-time detection of Hα flares and filaments established at Kanzelhöhe Observatory (KSO; Austria) in the frame of the space weather segment of the ESA Space Situational Awareness programme (swe.ssa.esa.int). An evaluation of the system, which is continuously running since July 2013 is provided, covering an evaluation period of almost 2.5 years. During this period, KSO provided 3020 hours of real-time Hα observations at the ESA SWE portal. In total, 824 Hα flares were detected and classified by the real-time detection system, including 174 events of Hα importance class 1 and larger. For the total sample of events, 95 % of the automatically determined flare peak times lie within ±5 min of the values given in the official optical flares reports (by NOAA and KSO), and 76 % of the start times. The heliographic positions determined are better than ±5°. The probability of detection of flares of importance 1 or larger is 95 %, with a false alarm rate of 16 %. These numbers confirm the high potential of automatic flare detection and alerting from ground

  14. Efficiency of Vertical Geothermal Heat Exchangers in the Ground Source Heat Pump System

    Institute of Scientific and Technical Information of China (English)

    Heyi Zeng; Nairen Diao; Zhaohong Fang

    2003-01-01

    Taking the fluid temperature distribution along the borehole depth into account, a new quasi-three-dimensional model for vertical ground heat exchangers has been established, which provides a better understanding of the heat transfer processes in the geothermal heat exchangers. On this basis the efficiency of the borehole has been defined and its analytical expression derived. Comparison with the previous two-dimensional model shows that the quasi-three-dimensional model is more rational and more accurate to depict the practical feature of the conduction of geothermal heat exchanger, and the efficiency notion can be easily used to determine the inlet and outlet temperature of the circulating fluid inside the heat exchanger.

  15. 太阳能辅助地源热泵供暖实验研究%Experimental study of a solar assisted ground source heat pump for heating

    Institute of Scientific and Technical Information of China (English)

    赵忠超; 丰威仙; 巩学梅; 米浩君; 成华; 云龙

    2014-01-01

    An experimental study is performed to determine the performance of the solar assisted ground source heat pump(SAGSHP)by using a solar-ground source heat pump hybrid system in the city of Ningbo. The result shows that comparing with the ground source heat pump(GSHP),when the ratio of solar energy to the whole en-ergy is 41. 9% ,the coefficient of performance( COP)of the heat pump and system can improve 15. 1% and 7. 7% respectively. Therefore,the solar assisted ground source heat pump has a significant performance advan-tage according to the experimental result.%选取宁波某公用建筑的太阳能-地源热泵复合系统为实验系统,对太阳能辅助地源热泵( solar assisted ground source heat pump,SAGSHP)供暖进行了实验研究.研究结果表明:与单一的地源热泵(ground source heat pump,GSHP)相比,当太阳能承担41.9%负荷时,热泵机组和整个系统的能效比(coefficient of performance,COP)分别提高了15.1%和7.7%, SAGSHP 供暖运行模式具有明显的性能优势.

  16. Assessment of sources for higher Uranium concentration in ground waters of the Central Tamilnadu, India

    Science.gov (United States)

    Adithya, V. S.; Chidambaram, S.; Tirumalesh, K.; Thivya, C.; Thilagavathi, R.; Prasanna, M. V.

    2016-03-01

    The uranium concentration in groundwater has attained greater importance considering the health effects in mankind. Groundwater being the major source of uranium; sampling and analysis of groundwater for the major cations and anions along with uranium has been carried out in hard rock aquifers of Madurai district. The sampling has been carried out in varied aquifers like, Charnockites, Hornblende Biotite Gneiss, Granites, Quartzites, Laterites and sandstone. The cation and anions showed the following order of dominance Na+>Ca2+>Mg2+>K+ and that of anions are HCO3 ->Cl->SO4 2-> NO3 ->PO4 3-. Higher concentration of uranium was found along the granitic aquifers and it varied along the groundwater table condition. Further it was identified that the mineral weathering was the predominant source of U in groundwater. Tritium studies also reveal the fact that the younger waters are more enriched in uranium than the older groundwater with longer residence time.

  17. An interdisciplinary assessment of regional-scale nonpoint source ground-water vulnerability; theory and application

    Science.gov (United States)

    Bernknopf, Richard L.; Dinitz, Laura B.; Loague, Keith

    2001-01-01

    An integrated earth science-economics model, developed within a geographic information system (GIS), combines a regional-scale nonpoint source vulnerability assessment with a specific remediation measure to avoid unnecessary agricultural production costs associated with the use of agrochemicals in the Pearl Harbor basin on the island of Oahu, Hawaii. This approach forms the core of a risk-based regulation for the application of agrochemicals and estimates the benefits of an information-based approach to decisionmaking.

  18. Wire bonding in microelectronics

    CERN Document Server

    Harman, George G

    2010-01-01

    Wire Bonding in Microelectronics, Third Edition, has been thoroughly revised to help you meet the challenges of today's small-scale and fine-pitch microelectronics. This authoritative guide covers every aspect of designing, manufacturing, and evaluating wire bonds engineered with cutting-edge techniques. In addition to gaining a full grasp of bonding technology, you'll learn how to create reliable bonds at exceedingly high yields, test wire bonds, solve common bonding problems, implement molecular cleaning methods, and much more. Coverage includes: Ultrasonic bonding systems and technologies, including high-frequency systems Bonding wire metallurgy and characteristics, including copper wire Wire bond testing Gold-aluminum intermetallic compounds and other interface reactions Gold and nickel-based bond pad plating materials and problems Cleaning to improve bondability and reliability Mechanical problems in wire bonding High-yield, fine-pitch, specialized-looping, soft-substrate, and extreme-temperature wire bo...

  19. ANEMOS: A computer code to estimate air concentrations and ground deposition rates for atmospheric nuclides emitted from multiple operating sources

    Energy Technology Data Exchange (ETDEWEB)

    Miller, C.W.; Sjoreen, A.L.; Begovich, C.L.; Hermann, O.W.

    1986-11-01

    This code estimates concentrations in air and ground deposition rates for Atmospheric Nuclides Emitted from Multiple Operating Sources. ANEMOS is one component of an integrated Computerized Radiological Risk Investigation System (CRRIS) developed for the US Environmental Protection Agency (EPA) for use in performing radiological assessments and in developing radiation standards. The concentrations and deposition rates calculated by ANEMOS are used in subsequent portions of the CRRIS for estimating doses and risks to man. The calculations made in ANEMOS are based on the use of a straight-line Gaussian plume atmospheric dispersion model with both dry and wet deposition parameter options. The code will accommodate a ground-level or elevated point and area source or windblown source. Adjustments may be made during the calculations for surface roughness, building wake effects, terrain height, wind speed at the height of release, the variation in plume rise as a function of downwind distance, and the in-growth and decay of daughter products in the plume as it travels downwind. ANEMOS can also accommodate multiple particle sizes and clearance classes, and it may be used to calculate the dose from a finite plume of gamma-ray-emitting radionuclides passing overhead. The output of this code is presented for 16 sectors of a circular grid. ANEMOS can calculate both the sector-average concentrations and deposition rates at a given set of downwind distances in each sector and the average of these quantities over an area within each sector bounded by two successive downwind distances. ANEMOS is designed to be used primarily for continuous, long-term radionuclide releases. This report describes the models used in the code, their computer implementation, the uncertainty associated with their use, and the use of ANEMOS in conjunction with other codes in the CRRIS. A listing of the code is included in Appendix C.

  20. Wire harness twisting aid

    Science.gov (United States)

    Casey, E. J.; Commadore, C. C.; Ingles, M. E.

    1980-01-01

    Long wire bundles twist into uniform spiral harnesses with help of simple apparatus. Wires pass through spacers and through hand-held tool with hole for each wire. Ends are attached to low speed bench motor. As motor turns, operator moves hand tool away forming smooth twists in wires between motor and tool. Technique produces harnesses that generate less radio-frequency interference than do irregularly twisted cables.

  1. Tracing nitrate pollution sources and transformation in surface- and ground-waters using environmental isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yan [Key Laboratory of Ecosystem Network Observation and Modeling, Institute of Geographic Sciences and Natural Resources Research, Chinese Academy of Sciences, Beijing 100101 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Li, Fadong, E-mail: lifadong@igsnrr.ac.cn [Key Laboratory of Ecosystem Network Observation and Modeling, Institute of Geographic Sciences and Natural Resources Research, Chinese Academy of Sciences, Beijing 100101 (China); Zhang, Qiuying [Center for Agricultural Resources Research, Chinese Academy of Sciences, Shijiazhuang 050021 (China); Li, Jing [Key Laboratory of Ecosystem Network Observation and Modeling, Institute of Geographic Sciences and Natural Resources Research, Chinese Academy of Sciences, Beijing 100101 (China); Liu, Qiang [Key Laboratory of Ecosystem Network Observation and Modeling, Institute of Geographic Sciences and Natural Resources Research, Chinese Academy of Sciences, Beijing 100101 (China); University of Chinese Academy of Sciences, Beijing 100049 (China)

    2014-08-15

    Water pollution in the form of nitrate nitrogen (NO{sub 3}{sup −}–N) contamination is a major concern in most agricultural areas in the world. Concentrations and nitrogen and oxygen isotopic compositions of nitrate, as well as oxygen and deuterium isotopic compositions of surface and groundwater from a typical irrigated region in the North China Plain (NCP) collected from May to October in 2012 were analyzed to examine the major nitrate sources and transformations. Concentrations of NO{sub 3}{sup −}–N ranged from 0.2 to 29.6 mg/L (mean of 11.2 mg/L) in surface water, and from 0.1 to 19.4 mg/L (mean of 2.8 mg/L) in groundwater. Approximately 46.7% of the surface water samples and 10% of the groundwater samples exceeded the World Health Organization (WHO) drinking water standard for NO{sub 3}{sup −}–N. Surface water samples that exceeded the standard were collected mainly in the dry season (May and October), while groundwater samples that exceeded the standard were collected in the wet season (June). Overall, the highest nitrate levels were observed in surface water in May and in groundwater in June, indicating that fertilizer application, precipitation, and irrigation strongly influence the NO{sub 3}{sup −}–N concentrations. Analyses of isotopic compositions suggest that the main sources of nitrate are nitrification of fertilizer and sewage in surface water, in contrast, mineralization of soil organic N and sewage is the groundwater sources during the dry season. When fertilizers are applied, nitrate will be transported by precipitation through the soil layers to the groundwater in the wet season (June). Denitrification only occurred in surface water in the wet season. Attempts should be made to minimize overuse of nitrogen fertilizers and to improve nitrogen use efficiency in irrigated agricultural regions. - Highlights: • Nitrate sources in surface and groundwater were identified by multiple isotopes. • Nitrate pollution displayed obvious

  2. Ground and aircraft-based methane measurements in Siberia: source attribution using tracers and models

    Science.gov (United States)

    Arzoumanian, E.; Paris, J. D.; Pruvost, A.; Peng, S.; Turquety, S.; Berchet, A.; Pison, I.; Helle, J.; Arshinov, M.; Belan, B. D.

    2015-12-01

    Methane (CH4) is the second most important anthropogenic greenhouse gas. It is also naturally emitted by a number of processes, including microbial activity in wetlands, permafrost degradation and wildfires. Our current understanding of the extent and amplitude of its natural sources, as well as the large scale driving factors, remain highly uncertain (Kirschke et al., Nature Geosci., 2013). Furthermore, high latitude regions are large natural sources of CH4 in the atmosphere. Observing boreal/Arctic CH4 variability and understanding its main driving processes using atmospheric measurements and transport model is the task of this work. YAK-AEROSIB atmospheric airborne campaigns (flights in the tropospheric layer up to 9 km connecting the two cities of Novosibirsk and Yakutsk) and continuous measurements at Fonovaya Observatory (60 km west of Tomsk - 56° 25'07"N, 84° 04'27"E) have been performed in order to provide observational data on the composition of Siberian air. The study is focused on 2012, during which a strong heat wave impacted Siberia, leading to the highest mean daily temperature values on record since the beginning of the 20th century. This abnormal drought has led to numerous large forest fires. A chemistry-transport model (CHIMERE), combined with datasets for anthropogenic (EDGAR) emissions and models for wetlands (ORCHIDEE) and wildfires (APIFLAME), is used to determine contributions of CH4 sources in the region. Recent results concerning CH4 fluxes and its atmospheric variability in the Siberian territory derived from a modeled-based analysis will be shown and discussed. This work was funded by CNRS (France), the French Ministry of Foreign Affairs, CEA (France), Presidium of RAS (Program No. 4), Brunch of Geology, Geophysics and Mining Sciences of RAS (Program No. 5), Interdisciplinary integration projects of Siberian Branch of RAS (No. 35, No. 70, No. 131), Russian Foundation for Basic Research (grants No 14-05-00526, 14-05-00590). Kirschke, S

  3. Discrete and continuum simulations of near-field ground motion from Source Physics Experiments (SPE) (Invited)

    Science.gov (United States)

    Ezzedine, S. M.; Vorobiev, O.; Herbold, E. B.; Glenn, L. A.; Antoun, T.

    2013-12-01

    This work is focused on analysis of near-field measurements (up to 100 m from the source) recorded during Source Physics Experiments in a granitic formation. One of the main goals of these experiments is to investigate the possible mechanisms of shear wave generation in the nonlinear source region. SPE experiments revealed significant tangential motion (up to 30 % of the magnitude in the radial direction) at many locations. Furthermore, azimuthal variations in radial velocities were also observed which cannot be generated by a spherical source in isotropic materials. Understanding the nature of this non-radial motion is important for discriminating between the natural seismicity and underground explosions signatures. Possible mechanisms leading to such motion include, but not limited to, heterogeneities in the rock such as joints, faults and geologic layers as well as surface topography and vertical motion at the surface caused by material spall and gravity. We have performed a three dimensional computational studies considering all these effects. Both discrete and continuum methods have been employed to model heterogeneities. In the discrete method, the joints and faults were represented by cohesive contact elements. This enables us to examine various friction laws at the joints which include softening, dilatancy, water saturation and rate-dependent friction. Yet this approach requires the mesh to be aligned with joints, which may present technical difficulties in three dimensions when multiple non-persistent joints are present. In addition, the discrete method is more computationally expensive. The continuum approach assumes that the joints are stiff and the dilatancy and shear softening can be neglected. In this approach, the joints are modeled as weakness planes within the material, which are imbedded into and pass through many finite elements. The advantage of this approach is that it requires neither sophisticated meshing algorithms nor contact detection

  4. Determination of fluoride source in ground water using petrographic studies in Dashtestan area, south of Iran

    Science.gov (United States)

    Battaleb-Looie, Sedigheh; Moore, Farid, ,, Dr.

    2010-05-01

    The groundwater occurs in Dashtestan area, contains a high level of fluoride. Since groundwater is vastly used for drinking and irrigation purposes, the local residents are at high risk of fluoride toxicity, as already evidenced by the occurrence of dental Fluorosis in many residents. 35 surface and groundwater samples were collected in September, 2009. The results show that in 23 samples the fluoride concentration is above the permissible level (1.5ppm). Petrographic study of lithological units in the catchment area indicates that mica minerals are the most probable source of fluoride content in the study area.

  5. Construction Technology of Soil Source Heat Exchanger of Ground Source Heat Pump%地源热泵土壤源换热器的施工技术

    Institute of Scientific and Technical Information of China (English)

    程金明; 王巧真

    2007-01-01

    地源热泵(Ground Source Heat Pump, GSHP)作为最有发展潜力的热泵技术在各级政府的积极推介下发展迅速,但由于地源换热器施工安装成本高,技术的发展遇到了很大的阻力.探讨了土壤源换热器施工技术和土壤源换热器的热平衡问题,力图提高土源换热器施工技术,降低地源热泵成本,促进该技术的推广应用.

  6. Water Desalination with Wires

    NARCIS (Netherlands)

    Porada, S.; Sales, B.B.; Hamelers, H.V.M.; Biesheuvel, P.M.

    2012-01-01

    We show the significant potential of water desalination using a novel capacitive wire-based technology in which anode/cathode wire pairs are constructed from coating a thin porous carbon electrode layer on top of electrically conducting rods (or wires). By alternately dipping an array of electrode

  7. Integrating the Gradient of the Thin Wire Kernel

    Science.gov (United States)

    Champagne, Nathan J.; Wilton, Donald R.

    2008-01-01

    A formulation for integrating the gradient of the thin wire kernel is presented. This approach employs a new expression for the gradient of the thin wire kernel derived from a recent technique for numerically evaluating the exact thin wire kernel. This approach should provide essentially arbitrary accuracy and may be used with higher-order elements and basis functions using the procedure described in [4].When the source and observation points are close, the potential integrals over wire segments involving the wire kernel are split into parts to handle the singular behavior of the integrand [1]. The singularity characteristics of the gradient of the wire kernel are different than those of the wire kernel, and the axial and radial components have different singularities. The characteristics of the gradient of the wire kernel are discussed in [2]. To evaluate the near electric and magnetic fields of a wire, the integration of the gradient of the wire kernel needs to be calculated over the source wire. Since the vector bases for current have constant direction on linear wire segments, these integrals reduce to integrals of the form

  8. Sources of ground movement at Vesuvius before the AD 79 eruption: Evidence from contemporary accounts and archaeological studies

    Science.gov (United States)

    Marturano, Aldo

    2008-11-01

    Historical sources have recorded earthquake shocks, their effects and difficulties that local inhabitants experienced before the AD 79 Pompeii eruption. Archaeological studies pointed out the effects of such seismicity, and have also evidenced that several water crises were occurring at Pompeii in that period. Indeed numerous sources show that, at the time of eruption, and probably some time before, the civic aqueduct, having ceased to be supplied by the regional one, was out of order and that a new one was being built. Since Roman aqueducts were usually built with a recommended minimum mean slope of 20 cm/km and Pompeii's aqueduct sloped from the nearby Apennines toward the town, this slope could have been easily cancelled by uplift that occurred in the area even if this was only moderate. For the crustal deformations a volcanic origin is proposed and a point source model is used to explain the observations. Simple analysis of the available data suggests that the ground deformations were caused by a < 2 km 3 volumetric change at a depth of ˜ 8 km that happened over the course of several decades.

  9. A high flux pulsed source of energetic atomic oxygen. [for spacecraft materials ground testing

    Science.gov (United States)

    Krech, Robert H.; Caledonia, George E.

    1986-01-01

    The design and demonstration of a pulsed high flux source of nearly monoenergetic atomic oxygen are reported. In the present test setup, molecular oxygen under several atmospheres of pressure is introduced into an evacuated supersonic expansion nozzle through a pulsed molecular beam valve. A 10J CO2 TEA laser is focused to intensities greater than 10 to the 9th W/sq cm in the nozzle throat, generating a laser-induced breakdown with a resulting 20,000-K plasma. Plasma expansion is confined by the nozzle geometry to promote rapid electron-ion recombination. Average O-atom beam velocities from 5-13 km/s at fluxes up to 10 to the 18th atoms/pulse are measured, and a similar surface oxygen enrichment in polyethylene samples to that obtained on the STS-8 mission is found.

  10. Effect of wire shape on wire array discharge

    Energy Technology Data Exchange (ETDEWEB)

    Shimomura, N.; Tanaka, Y.; Yushita, Y.; Nagata, M. [University of Tokushima, Department of Electrical and Electronic Engineering, Tokushima (Japan); Teramoto, Y.; Katsuki, S.; Akiyama, H. [Kumamoto University, Department of Electrical and Computer Engineering, Kumamoto (Japan)

    2001-09-01

    Although considerable investigations have been reported on z-pinches to achieve nuclear fusion, little attention has been given from the point of view of how a wire array consisting of many parallel wires explodes. Instability existing in the wire array discharge has been shown. In this paper, the effect of wire shape in the wire array on unstable behavior of the wire array discharge is represented by numerical analysis. The claws on the wire formed in installation of wire may cause uniform current distribution on wire array. The effect of error of wire diameter in production is computed by Monte Carlo Method. (author)

  11. Technical Feasibility Study for Deployment of Ground-Source Heat Pump Systems: Portsmouth Naval Shipyard -- Kittery, Maine

    Energy Technology Data Exchange (ETDEWEB)

    Hillesheim, M.; Mosey, G.

    2014-11-01

    The U.S. Environmental Protection Agency (EPA) Office of Solid Waste and Emergency Response, in accordance with the RE-Powering America's Lands initiative, engaged the U.S. Department of Energy's (DOE) National Renewable Energy Laboratory (NREL) to conduct feasibility studies to assess the viability of developing renewable energy generating facilities on contaminated sites. Portsmouth Naval Shipyard (PNSY) is a United States Navy facility located on a series of conjoined islands in the Piscataqua River between Kittery, ME and Portsmouth, NH. EPA engaged NREL to conduct a study to determine technical feasibility of deploying ground-source heat pump systems to help PNSY achieve energy reduction goals.

  12. PS wire chamber

    CERN Multimedia

    1970-01-01

    A wire chamber used at CERN's Proton Synchrotron accelerator in the 1970s. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  13. Ground motion in the presence of complex Topography II: Earthquake sources and 3D simulations

    Science.gov (United States)

    Hartzell, Stephen; Ramirez-Guzman, Leonardo; Meremonte, Mark; Leeds, Alena L.

    2017-01-01

    Eight seismic stations were placed in a linear array with a topographic relief of 222 m over Mission Peak in the east San Francisco Bay region for a period of one year to study topographic effects. Seventy‐two well‐recorded local earthquakes are used to calculate spectral amplitude ratios relative to a reference site. A well‐defined fundamental resonance peak is observed with individual station amplitudes following the theoretically predicted progression of larger amplitudes in the upslope direction. Favored directions of vibration are also seen that are related to the trapping of shear waves within the primary ridge dimensions. Spectral peaks above the fundamental one are also related to topographic effects but follow a more complex pattern. Theoretical predictions using a 3D velocity model and accurate topography reproduce many of the general frequency and time‐domain features of the data. Shifts in spectral frequencies and amplitude differences, however, are related to deficiencies of the model and point out the importance of contributing factors, including the shear‐wave velocity under the topographic feature, near‐surface velocity gradients, and source parameters.

  14. 土壤含水率及渗流对土壤源热泵影响研究进展%Research development on the impact of ground moisture content and seepage upon ground source heat pump

    Institute of Scientific and Technical Information of China (English)

    段妍; 晋华; 刘虎

    2012-01-01

    主要介绍了土壤含水率和地下水渗流两个主要水文地质因素,具体分析了两因素在实验和数值模拟方面对土壤源热泵地埋管换热能力的影响,并指出了土壤源热泵在水文地质因素研究方面存在的问题和今后发展的方向,为土壤源热泵运行的稳定性及经济效益的最大化提供保障。%The thesis mainly introduces ground moisture content and underground water seepage,specifically analyzes the impact of ground moisture content and underground water seepage upon ground source heat pump heat-exchanging ability in the two aspects of experiments and numerical simulation,and points out existing problems and development trend of ground source heat pump in the angle of hydrogeology,which has provided maximum guarantee for stable and economic operation of ground source heat pump.

  15. The Analysis of Ground Source Heat Pump Applied in Mianyang City%地源热泵在绵阳地区的应用分析

    Institute of Scientific and Technical Information of China (English)

    刘东; 蒋斌; 韩如冰; 邹国荣

    2013-01-01

      介绍了地源热泵的工作原理,并结合绵阳地区的地质情况及地源热泵系统形式,分析了地源热泵技术在绵阳地区的应用方式,并针对地表水、地下水和地下耦合地源热泵系统的可行性进行了分析和说明,为地源热泵技术在绵阳地区的工程应用提供参考。%This paper introduced the operational principle of ground source heat pump. Based on the geologic environment of Mianyang city and the ground source heat pump forms, the application of different ground source heat pump were compared. And analyses the feasibility of surface water,ground water and underground coupling source heat pump in Mianyang city. This paper can provide the reference for the ground source heat pump engineering application in Mianyang city.

  16. Graphene wire medium: Homogenization and application

    DEFF Research Database (Denmark)

    Andryieuski, Andrei; Chigrin, Dmitry N.; Lavrinenko, Andrei

    2012-01-01

    In this contribution we analyze numerically the optical properties of the graphene wire medium, which unit cell consists of a stripe of graphene embedded into dielectric. We propose a simple method for retrieval of the isofrequency contour and effective permittivity tensor. As an example...... of the graphene wire medium application we demonstrate a reconfigurable hyperlens for the terahertz subwavelength imaging capable of resolving two sources with separation λ0/5 in the far-field....

  17. Exergy cost analysis of ground source heat pump system%土壤源热泵系统的火用成本分析

    Institute of Scientific and Technical Information of China (English)

    龚光彩; 冯启辉; 苏欢; 徐春雯

    2011-01-01

    在对火用分析与经济学原理研究的基础上,利用火用成本分析方法,建立了土壤源热泵系统的(火用) 成本分析模型.以实际的建筑空调系统为背景,运用所建火用成本分析模型与能量成本分析方法,对土壤源热泵系统与风冷热泵系统进行了对比分析计算,并以空气源热泵为基础对土壤源热泵进行了敏感性分析.对土壤源热泵的实际应用具有指导意义.%Based on the study of the exergy analysis and economics theory, an exergy cost analysis model of ground source heat pump system was established by using the exergy cost analysis method. With the background of an actual building air - conditioning system, the ground source heat pump system and the air source heat pump system were calculated by using exergy cost analysis model and energy cost analysis method. And the sensitivity analysis method was used in the exergy cost of ground source heat pump basing on air source heat pump. The analysis method has guiding significance for practical application of ground source heat pump.

  18. 地源热泵技术的推广与应用%The Promotion and Application of Ground Source Heat Pump Technology

    Institute of Scientific and Technical Information of China (English)

    张斌; 张力; 田忠春

    2013-01-01

      阐述了地源热泵的发展历程、工作原理、地源热泵种类和技术特点,例举了地源热泵技术在工程中的应用实例,分析了目前存在的需要注意的问题,对地源热泵技术的发展前景进行了展望。%In this text, several problems on the ground source heat pump are researched, such as its development history, principle of operation, the kind of ground source heat pump, technical characteristics and application examples of engineering technology. The paper also analyses the current problems and look further into the future of ground source heat pump.

  19. 30 CFR 77.1802 - Insulation of trolley wires, trolley feeder wires and bare signal wires; guarding of trolley...

    Science.gov (United States)

    2010-07-01

    ... wires and bare signal wires; guarding of trolley wires and trolley feeder wires. 77.1802 Section 77.1802... Wires and Trolley Feeder Wires § 77.1802 Insulation of trolley wires, trolley feeder wires and bare..., and bare signal wires shall be adequately guarded: (a) At all points where men are required to work or...

  20. 包头市某地源热泵工程设计%Ground-source heat pump project design in Baotou

    Institute of Scientific and Technical Information of China (English)

    张士领

    2014-01-01

    Ground heat exchanger system is the key to the smooth running of the ground-source heat pump system.Through the ground-source heat pump system design idea,the ground heat exchanger system selection calculation,and the project cooling and heating load comparative analysis,adopts the gas boiler as the system peak load heat source.To reduce the energy consumption,combined with the characteristics of radiant cooling terminal,supplies the ground source water cooling directly in transition seasons,and obtains good energy conservation effect.%地埋管换热系统是整个地源热泵系统能否良好运行的关键。通过对地源热泵系统设计思路、地埋管换热系统选择计算、工程冷热负荷的对比分析,采用燃气锅炉作为系统的调峰热源。为减少能源消耗,结合工程末端为辐射供冷的特点,在过渡季节使用地源水直接供冷,取得了较好的节能效果。

  1. Vibrating wire alignment technique

    CERN Document Server

    Xiao-Long, Wang; lei, Wu; Chun-Hua, Li

    2013-01-01

    Vibrating wire alignment technique is a kind of method which through measuring the spatial distribution of magnetic field to do the alignment and it can achieve very high alignment accuracy. Vibrating wire alignment technique can be applied for magnet fiducialization and accelerator straight section components alignment, it is a necessary supplement for conventional alignment method. This article will systematically expound the international research achievements of vibrating wire alignment technique, including vibrating wire model analysis, system frequency calculation, wire sag calculation and the relation between wire amplitude and magnetic induction intensity. On the basis of model analysis this article will introduce the alignment method which based on magnetic field measurement and the alignment method which based on amplitude and phase measurement. Finally, some basic questions will be discussed and the solutions will be given.

  2. Optimization of ground source heat pumps related to soil and groundwater conditions as well as grouting material; Optimierung von Waermepumpen in Bezug auf Boden- und Grundwasserverhaeltnisse sowie Verpressmaterial

    Energy Technology Data Exchange (ETDEWEB)

    Katzenbach, R.; Clauss, F.; Waberseck, T. [Technische Univ. Darmstadt (Germany). Inst. und Versuchsanstalt fuer Geotechnik; Sass, J. [Technische Univ. Darmstadt (Germany). Inst. fuer Angewandte Geowissenschaften, Fachgebiet Ingenieurgeologie

    2006-07-01

    The capacity and the performance of ground source heat pumps and seasonal thermal storage systems with borehole heat exchangers depend on the conditions of the encountered subsoil and the groundwater and furthermore on the thermal properties of the grouting material used for conclusive backfilling of the annular space after installing the heat exchanger pipes in the borehole. Intensive investigations are carried out at the Technische Universitaet Darmstadt with the aim of an economical optimisation of the dimensioning of ground source heat pumps and seasonal thermal storage systems. (orig.)

  3. Wire + Arc Additive Manufacturing

    OpenAIRE

    Williams, Stewart W.; Martina, Filomeno; Addison, Adrian C.; Ding, Jialuo; Pardal, Goncalo; Colegrove, Paul A.

    2016-01-01

    Depositing large components (>10 kg) in titanium, aluminium, steel and other metals is possible using Wire + Arc Additive Manufacturing. This technology adopts arc welding tools and wire as feedstock for additive manufacturing purposes. High deposition rates, low material and equipment costs, and good structural integrity make Wire+Arc Additive Manufacturing a suitable candidate for replacing the current method of manufacturing from solid billets or large forgings, especially with regards to ...

  4. The SCEC Broadband Platform: A Collaborative Open-Source Software Package for Strong Ground Motion Simulation and Validation

    Science.gov (United States)

    Silva, F.; Maechling, P. J.; Goulet, C. A.; Somerville, P.; Jordan, T. H.

    2014-12-01

    The Southern California Earthquake Center (SCEC) Broadband Platform is a collaborative software development project involving geoscientists, earthquake engineers, graduate students, and the SCEC Community Modeling Environment. The SCEC Broadband Platform (BBP) is open-source scientific software that can generate broadband (0-100Hz) ground motions for earthquakes, integrating complex scientific modules that implement rupture generation, low and high-frequency seismogram synthesis, non-linear site effects calculation, and visualization into a software system that supports easy on-demand computation of seismograms. The Broadband Platform operates in two primary modes: validation simulations and scenario simulations. In validation mode, the Platform runs earthquake rupture and wave propagation modeling software to calculate seismograms for a well-observed historical earthquake. Then, the BBP calculates a number of goodness of fit measurements that quantify how well the model-based broadband seismograms match the observed seismograms for a certain event. Based on these results, the Platform can be used to tune and validate different numerical modeling techniques. In scenario mode, the Broadband Platform can run simulations for hypothetical (scenario) earthquakes. In this mode, users input an earthquake description, a list of station names and locations, and a 1D velocity model for their region of interest, and the Broadband Platform software then calculates ground motions for the specified stations. Working in close collaboration with scientists and research engineers, the SCEC software development group continues to add new capabilities to the Broadband Platform and to release new versions as open-source scientific software distributions that can be compiled and run on many Linux computer systems. Our latest release includes 5 simulation methods, 7 simulation regions covering California, Japan, and Eastern North America, the ability to compare simulation results

  5. Azimuthal Dependence of the Ground Motion Variability from Scenario Modeling of the 2014 Mw6.0 South Napa, California, Earthquake Using an Advanced Kinematic Source Model

    Science.gov (United States)

    Gallovič, F.

    2016-11-01

    Strong ground motion simulations require physically plausible earthquake source model. Here, I present the application of such a kinematic model introduced originally by Ruiz et al. (Geophys J Int 186:226-244, 2011). The model is constructed to inherently provide synthetics with the desired omega-squared spectral decay in the full frequency range. The source is composed of randomly distributed overlapping subsources with fractal number-size distribution. The position of the subsources can be constrained by prior knowledge of major asperities (stemming, e.g., from slip inversions), or can be completely random. From earthquake physics point of view, the model includes positive correlation between slip and rise time as found in dynamic source simulations. Rupture velocity and rise time follows local S-wave velocity profile, so that the rupture slows down and rise times increase close to the surface, avoiding unrealistically strong ground motions. Rupture velocity can also have random variations, which result in irregular rupture front while satisfying the causality principle. This advanced kinematic broadband source model is freely available and can be easily incorporated into any numerical wave propagation code, as the source is described by spatially distributed slip rate functions, not requiring any stochastic Green's functions. The source model has been previously validated against the observed data due to the very shallow unilateral 2014 Mw6 South Napa, California, earthquake; the model reproduces well the observed data including the near-fault directivity (Seism Res Lett 87:2-14, 2016). The performance of the source model is shown here on the scenario simulations for the same event. In particular, synthetics are compared with existing ground motion prediction equations (GMPEs), emphasizing the azimuthal dependence of the between-event ground motion variability. I propose a simple model reproducing the azimuthal variations of the between-event ground motion

  6. Research Progress of Composite Ground Source Heat Pump Air Conditioning System%复合地源热泵系统的研究进展探讨

    Institute of Scientific and Technical Information of China (English)

    程晋洋; 朱彩霞; 李晓光

    2015-01-01

    The paper mainly introduces the advantages of ground source heat pump and its development trend, the classification and working principle of composite ground source heat pump depend on various forms of cold and heat source. The research status both at home and abroad in different times are expounded, analyzing the reason of heat imbalance and coefficient of performance reduction caused by long-term use of ground source heat pump system. A series of recommendations are proposed to improve the performance of ground source heat pump as the direction for the future research.%主要介绍地源热泵的优点及其发展趋势,以及不同冷热源形式的复合地源热泵的分类及其工作原理。探讨了不同时期复合地源热泵国内外的研究现状,分析了地源热泵长期使用系统热量失衡、COP 减小的原因,并提出一些改善地源热泵性能的建议,为其今后的研究提供方向。

  7. Charpak hemispherical wire chamber

    CERN Multimedia

    1970-01-01

    pieces. Mesures are of the largest one. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  8. Photovoltaic Wire Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovation Research Phase I project will investigate a new architecture for photovoltaic devices based on nanotechnology: photovoltaic wire. The...

  9. On-Wire Lithography

    National Research Council Canada - National Science Library

    Lidong Qin; Sungho Park; Ling Huang; Chad A. Mirkin

    2005-01-01

    .... This procedure, termed on-wire lithography, combines advances in template-directed synthesis of nanowires with electrochemical deposition and wet-chemical etching and allows routine fabrication...

  10. 1998 wire development workshop proceedings

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-04-01

    This report consists of vugraphs of the presentations at the conference. The conference was divided into the following sessions: (1) First Generation Wire Development: Status and Issues; (2) First Generation Wire in Pre-Commercial Prototypes; (3) Second Generation Wire Development: Private Sector Progress and Issues; (4) Second Generation Wire Development: Federal Laboratories; and (5) Fundamental Research Issues for HTS Wire Development.

  11. Case Study for the ARRA-funded Ground Source Heat Pump Demonstration at Denver Museum of Nature & Science

    Energy Technology Data Exchange (ETDEWEB)

    Im, Piljae [ORNL; Liu, Xiaobing [ORNL

    2016-09-01

    High initial costs and lack of public awareness of ground-source heat pump (GSHP) technology are the two major barriers preventing rapid deployment of this energy-saving technology in the United States. Under the American Recovery and Reinvestment Act (ARRA), 26 GSHP projects were competitively selected and carried out to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. This report highlights the findings of a case study of one such GSHP demonstration projects that uses a recycled water heat pump (RWHP) system installed at the Denver Museum of Nature & Science in Denver, Colorado. The RWHP system uses recycled water from the city’s water system as the heat sink and source for a modular water-to-water heat pump (WWHP). This case study was conducted based on the available measured performance data from December 2014 through August 2015, utility bills of the building in 2014 and 2015, construction drawings, maintenance records, personal communications, and construction costs. The annual energy consumption of the RWHP system was calculated based on the available measured data and other related information. It was compared with the performance of a baseline scenario— a conventional VAV system using a water-cooled chiller and a natural gas fired boiler, both of which have the minimum energy efficiencies allowed by ASHRAE 90.1-2010. The comparison was made to determine energy savings, operating cost savings, and CO2 emission reductions achieved by the RWHP system. A cost analysis was performed to evaluate the simple payback of the RWHP system. Summarized below are the results of the performance analysis, the learned lessons, and recommended improvement in the operation of the RWHP system.

  12. Case Study for the ARRA-funded Ground Source Heat Pump Demonstration at Denver Museum of Nature & Science

    Energy Technology Data Exchange (ETDEWEB)

    Im, Piljae [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Energy and Transportation Science Division; Liu, Xiaobing [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Energy and Transportation Science Division

    2015-11-30

    High initial costs and lack of public awareness of ground-source heat pump (GSHP) technology are the two major barriers preventing rapid deployment of this energy-saving technology in the United States. Under the American Recovery and Reinvestment Act (ARRA), 26 GSHP projects were competitively selected and carried out to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. This report highlights the findings of a case study of one such GSHP demonstration projects that uses a recycled water heat pump (RWHP) system installed at the Denver Museum of Nature & Science in Denver, Colorado. The RWHP system uses recycled water from the city’s water system as the heat sink and source for a modular water-to-water heat pump (WWHP). This case study was conducted based on the available measured performance data from December 2014 through August 2015, utility bills of the building in 2014 and 2015, construction drawings, maintenance records, personal communications, and construction costs. The annual energy consumption of the RWHP system was calculated based on the available measured data and other related information. It was compared with the performance of a baseline scenario— a conventional VAV system using a water-cooled chiller and a natural gas fired boiler, both of which have the minimum energy efficiencies allowed by ASHRAE 90.1-2010. The comparison was made to determine energy savings, operating cost savings, and CO2 emission reductions achieved by the RWHP system. A cost analysis was performed to evaluate the simple payback of the RWHP system. Summarized below are the results of the performance analysis, the learned lessons, and recommended improvement in the operation of the RWHP system.

  13. Methods and Data Used to Investigate Polonium-210 as a Source of Excess Gross-Alpha Radioactivity in Ground Water, Churchill County, Nevada

    Science.gov (United States)

    Seiler, Ralph L.

    2007-01-01

    Ground water is the major source of drinking water in the Carson River Basin, California and Nevada. Previous studies have shown that uranium and gross-alpha radioactivities in ground water can be greater than U.S. Environmental Protection Agency Maximum Contaminant Levels, particularly in the Carson Desert, Churchill County, Nevada. Studies also have shown that the primary source of the gross-alpha radioactivity and alpha-emitting radionuclides in ground water is the dissolution of uranium-rich granitic rocks and basin-fill sediments that have their origins in the Sierra Nevada. However, ground water sampled from some wells in the Carson Desert had gross-alpha radioactivities greater than could be accounted for by the decay of dissolved uranium. The occurrence of polonium-210 (Po-210) was hypothesized to explain the higher than expected gross-alpha radioactivities. This report documents and describes the study design, field and analytical methods, and data used to determine whether Po-210 is the source of excess gross-alpha radioactivity in ground water underlying the Carson Desert in and around Fallon, Nevada. Specifically, this report presents: 1) gross alpha and uranium radioactivities for 100 wells sampled from June to September 2001; and 2) pH, dissolved oxygen, specific conductance, and Po-210 radioactivity for 25 wells sampled in April and June 2007. Results of quality-control samples for the 2007 dataset are also presented.

  14. Simulation and design of ground source heat pump systems%地源热泵系统的模拟与设计

    Institute of Scientific and Technical Information of China (English)

    JeffreyD.Spitler; CenkYavuzturk; 等

    2003-01-01

    总结了近年来地源热泵系统的模拟和设计方面的研究和进展.首先给出了地源热泵系统各部件建模方面的进展,包括竖直埋管地热换热器、单井循环系统以及在地源热泵混合系统中采用的几种辅助散热装置.其次,讨论现场测定深层岩土热物性的技术.第三,介绍竖直埋管地热换热器的设计方法.最后,给出在设计地源热泵系统中采用系统模拟的几个应用实例.%This paper gives an overview of recent research and developments in ground source heat pump system simulation and design. First, developments related to modeling of components of the Ground Source Heat Pump (GSHP) system are presented-vertical ground loop heat exchanger, water source heat pump, standing column well, and several types of supplemental heat rejecters used in hybrid GSHP systems. Second, in situ measurement techniques for ground thermal properties are discussed. Third, a methodology for the design of the vertical ground loop heat exchanger is introduced. Last, several applications of using system simulation in the design of GSHP systems are presented.

  15. Development and Experimental Validation of a TRNSYS Dynamic Tool for Design and Energy Optimization of Ground Source Heat Pump Systems

    Directory of Open Access Journals (Sweden)

    Félix Ruiz-Calvo

    2017-09-01

    Full Text Available Ground source heat pump (GSHP systems stand for an efficient technology for renewable heating and cooling in buildings. To optimize not only the design but also the operation of the system, a complete dynamic model becomes a highly useful tool, since it allows testing any design modifications and different optimization strategies without actually implementing them at the experimental facility. Usually, this type of systems presents strong dynamic operating conditions. Therefore, the model should be able to predict not only the steady-state behavior of the system but also the short-term response. This paper presents a complete GSHP system model based on an experimental facility, located at Universitat Politècnica de València. The installation was constructed in the framework of a European collaborative project with title GeoCool. The model, developed in TRNSYS, has been validated against experimental data, and it accurately predicts both the short- and long-term behavior of the system.

  16. Impact factors on the long-term sustainability of Borehole Heat Exchanger coupled Ground Source Heat Pump System

    Science.gov (United States)

    Shao, Haibing; Hein, Philipp; Görke, Uwe-Jens; Bucher, Anke; Kolditz, Olaf

    2016-04-01

    In recent years, Ground Source Heat Pump System (GSHPS) has been recognized as an efficient technology to utilize shallow geothermal energy. Along with its wide application, some GSHPS are experiencing a gradual decrease in Borehole Heat Exchanger (BHE) outflow temperatures and thus have to be turned off after couple of years' operation. A comprehensive numerical investigation was then performed to model the flow and heat transport processes in and around the BHE, together with the dynamic change of heat pump efficiency. The model parameters were based on the soil temperature and surface weather condition in the Leipzig area. Different scenarios were modelled for a service life of 30 years, to reveal the evolution of BHE outflow and surrounding soil temperatures. It is found that lateral groundwater flow and using BHE for cooling will be beneficial to the energy recovery, along with the efficiency improvement of the heat pump. In comparison to other factors, the soil heat capacity and thermal conductivity are considered to have minor impact on the long-term sustainability of the system. Furthermore, the application of thermally enhanced grout material will improve the sustainability and efficiency. In contrast, it is very likely that undersized systems and improper grouting are the causes of strong system degradation.

  17. Wire Array Photovoltaics

    Science.gov (United States)

    Turner-Evans, Dan

    Over the past five years, the cost of solar panels has dropped drastically and, in concert, the number of installed modules has risen exponentially. However, solar electricity is still more than twice as expensive as electricity from a natural gas plant. Fortunately, wire array solar cells have emerged as a promising technology for further lowering the cost of solar. Si wire array solar cells are formed with a unique, low cost growth method and use 100 times less material than conventional Si cells. The wires can be embedded in a transparent, flexible polymer to create a free-standing array that can be rolled up for easy installation in a variety of form factors. Furthermore, by incorporating multijunctions into the wire morphology, higher efficiencies can be achieved while taking advantage of the unique defect relaxation pathways afforded by the 3D wire geometry. The work in this thesis shepherded Si wires from undoped arrays to flexible, functional large area devices and laid the groundwork for multijunction wire array cells. Fabrication techniques were developed to turn intrinsic Si wires into full p-n junctions and the wires were passivated with a-Si:H and a-SiNx:H. Single wire devices yielded open circuit voltages of 600 mV and efficiencies of 9%. The arrays were then embedded in a polymer and contacted with a transparent, flexible, Ni nanoparticle and Ag nanowire top contact. The contact connected >99% of the wires in parallel and yielded flexible, substrate free solar cells featuring hundreds of thousands of wires. Building on the success of the Si wire arrays, GaP was epitaxially grown on the material to create heterostructures for photoelectrochemistry. These cells were limited by low absorption in the GaP due to its indirect bandgap, and poor current collection due to a diffusion length of only 80 nm. However, GaAsP on SiGe offers a superior combination of materials, and wire architectures based on these semiconductors were investigated for multijunction

  18. A dual-amplifier hot-wire anemometer

    Science.gov (United States)

    Sadeh, W. Z.; Finn, C. L.

    1979-01-01

    The conceptual design of a dual-amplifier constant-temperature hot-wire anemometer is described. This hot-wire anemometer consists of three basic independent modules: a Wheatstone bridge in which the hot wire is one of its arms, an error-correction amplifier, and a voltage-controlled current source. The last two modules constitute the feedback network of this hot-wire anemometer. Thus the output voltage across the wire is a true function of the instantaneous changes in the wire resistance induced by the cooling effect of the flow. The dual-amplifier is capable of reaching relatively high frequency response through adequate selection of its active elements. Suitable gain of the error-correction amplifier and proper choice of the transfer function of the current source has yielded a frequency bandwidth up to 200 kHz.

  19. 暖通空调设计中地源热泵的运用%The Use of Ground Source Heat Pump in HVAC Design

    Institute of Scientific and Technical Information of China (English)

    杜志宏; 陈昀; 米泉龄; 尤炜

    2011-01-01

    地源热泵的能量来源是由各种资源所提供,主要包括了地源、水源、空气源等,当这些能量集中到一起之后能够与建筑物供冷供热的热泵技术想结合,由此处理成为城市供冷供暖的最佳方式.本文结合工程案例针对暖通空调设计中地源热泵问题进行了多方面的研究.%The energy sources of ground source heat pump are provided by various resources, including ground source, water source, air source, and others. When these energy is concentrated together, it can combine with cooling and heating heat pump technology of building, which became the best way to deal with urban cooling and heating. In this paper, the problems of ground source heat pump in design for HVAC are analyzed from many aspects with the projects.

  20. Using wire shaping techniques and holographic optics to optimize deposition characteristics in wire-based laser cladding

    Science.gov (United States)

    Goffin, N. J.; Higginson, R. L.; Tyrer, J. R.

    2016-12-01

    In laser cladding, the potential benefits of wire feeding are considerable. Typical problems with the use of powder, such as gas entrapment, sub-100% material density and low deposition rate are all avoided with the use of wire. However, the use of a powder-based source material is the industry standard, with wire-based deposition generally regarded as an academic curiosity. This is because, although wire-based methods have been shown to be capable of superior quality results, the wire-based process is more difficult to control. In this work, the potential for wire shaping techniques, combined with existing holographic optical element knowledge, is investigated in order to further improve the processing characteristics. Experiments with pre-placed wire showed the ability of shaped wire to provide uniformity of wire melting compared with standard round wire, giving reduced power density requirements and superior control of clad track dilution. When feeding with flat wire, the resulting clad tracks showed a greater level of quality consistency and became less sensitive to alterations in processing conditions. In addition, a 22% increase in deposition rate was achieved. Stacking of multiple layers demonstrated the ability to create fully dense, three-dimensional structures, with directional metallurgical grain growth and uniform chemical structure.

  1. An open-source, FireWire camera-based, Labview-controlled image acquisition system for automated, dynamic pupillometry and blink detection.

    Science.gov (United States)

    de Souza, John Kennedy Schettino; Pinto, Marcos Antonio da Silva; Vieira, Pedro Gabrielle; Baron, Jerome; Tierra-Criollo, Carlos Julio

    2013-12-01

    The dynamic, accurate measurement of pupil size is extremely valuable for studying a large number of neuronal functions and dysfunctions. Despite tremendous and well-documented progress in image processing techniques for estimating pupil parameters, comparatively little work has been reported on practical hardware issues involved in designing image acquisition systems for pupil analysis. Here, we describe and validate the basic features of such a system which is based on a relatively compact, off-the-shelf, low-cost FireWire digital camera. We successfully implemented two configurable modes of video record: a continuous mode and an event-triggered mode. The interoperability of the whole system is guaranteed by a set of modular software components hosted on a personal computer and written in Labview. An offline analysis suite of image processing algorithms for automatically estimating pupillary and eyelid parameters were assessed using data obtained in human subjects. Our benchmark results show that such measurements can be done in a temporally precise way at a sampling frequency of up to 120 Hz and with an estimated maximum spatial resolution of 0.03 mm. Our software is made available free of charge to the scientific community, allowing end users to either use the software as is or modify it to suit their own needs.

  2. 地源热泵技术的概念及应用%The Concept and Application of Ground Source Heat Pump Technology

    Institute of Scientific and Technical Information of China (English)

    程应欣

    2014-01-01

    Ground source heat pump is a new air conditioning heating method which features high efficiency, energy saving and environmental protection. The application of ground source heat pump technology facilitates the solvement of two major problems: energy crisis and environmental pol ution and thus brings opportunity of sustainable development of China. The development of ground source heat pump in China has a vast prospect. This paper starts with the origin of ground source heat pump, and then combines with analysis of its development both in China and abroad so as to put forward opinions and sug-gestions for the development of ground source heat pump technology in China.%地源热泵是一种集高效、节能、环保、有利于可持续发展于一身的新型空调采暖方式,地源热泵技术的应用有利于解决能源危机和环境污染这两个困扰中国发展的重大问题,进而为中国的可持续发展带来了契机,地源热泵在中国有广阔的发展前景。从地源热泵的由来入手,结合国内外地源热泵发展情况的分析,得出地源热泵的特点,从而为中国发展地源热泵技术提出了意见和建议。

  3. Source parameters of the 2013, Ms 7.0, Lushan earthquake and the characteristics of the near-fault strong ground motion

    Science.gov (United States)

    Zhao, Fengfan; Meng, Lingyuan

    2016-04-01

    The April 20, 2013 Ms 7.0, earthquake in Lushan city, Sichuan province of China occurred as the result of east-west oriented reverse-type motion on a north-south striking fault. The source location suggests the event occurred on the Southern part of Longmenshan fault at a depth of 13km. The maximum intensity is up to VIII to IX at Boxing and Lushan city, which are located in the meizoseismal area. In this study, we analyzed the dynamic source process with the source mechanism and empirical relationships, estimated the strong ground motion in the near-fault field based on the Brune's circle model. A dynamical composite source model (DCSM) has been developed to simulate the near-fault strong ground motion with associated fault rupture properties at Boxing and Lushan city, respectively. The results indicate that the frictional undershoot behavior in the dynamic source process of Lushan earthquake, which is actually different from the overshoot activity of the Wenchuan earthquake. Moreover, we discussed the characteristics of the strong ground motion in the near-fault field, that the broadband synthetic seismogram ground motion predictions for Boxing and Lushan city produced larger peak values, shorter durations and higher frequency contents. It indicates that the factors in near-fault strong ground motion was under the influence of higher effect stress drop and asperity slip distributions on the fault plane. This work is financially supported by the Natural Science Foundation of China (Grant No. 41404045) and by Science for Earthquake Resilience of CEA (XH14055Y).

  4. Sensitivity of broad-band ground-motion simulations to earthquake source and Earth structure variations: an application to the Messina Straits (Italy)

    KAUST Repository

    Imperatori, W.

    2012-03-01

    In this paper, we investigate ground-motion variability due to different faulting approximations and crustal-model parametrizations in the Messina Straits area (Southern Italy). Considering three 1-D velocity models proposed for this region and a total of 72 different source realizations, we compute broad-band (0-10 Hz) synthetics for Mw 7.0 events using a fault plane geometry recently proposed. We explore source complexity in terms of classic kinematic (constant rise-time and rupture speed) and pseudo-dynamic models (variable rise-time and rupture speed). Heterogeneous slip distributions are generated using a Von Karman autocorrelation function. Rise-time variability is related to slip, whereas rupture speed variations are connected to static stress drop. Boxcar, triangle and modified Yoffe are the adopted source time functions. We find that ground-motion variability associated to differences in crustal models is constant and becomes important at intermediate and long periods. On the other hand, source-induced ground-motion variability is negligible at long periods and strong at intermediate-short periods. Using our source-modelling approach and the three different 1-D structural models, we investigate shaking levels for the 1908 Mw 7.1 Messina earthquake adopting a recently proposed model for fault geometry and final slip. Our simulations suggest that peak levels in Messina and Reggio Calabria must have reached 0.6-0.7 g during this earthquake.

  5. Building America Case Study: Ground Source Heat Pump Research, TaC Studios Residence, Atlanta, Georigia (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    2014-09-01

    As part of the NAHB Research Center Industry Partnership, Southface partnered with TaC Studios, an Atlanta based architecture firm specializing in residential and light commercial design, on the construction of a new test home in Atlanta, GA in the mixed-humid climate. This home serves as a residence and home office for the firm's owners, as well as a demonstration of their design approach to potential and current clients. Southface believes the home demonstrates current best practices for the mixed-humid climate, including a building envelope featuring advanced air sealing details and low density spray foam insulation, glazing that exceeds ENERGY STAR requirements, and a high performance heating and cooling system. Construction quality and execution was a high priority for TaC Studios and was ensured by a third party review process. Post construction testing showed that the project met stated goals for envelope performance, an air infiltration rate of 2.15 ACH50. The homeowner's wished to further validate whole house energy savings through the project's involvement with Building America and this long-term monitoring effort. As a Building America test home, this home was evaluated to detail whole house energy use, end use loads, and the efficiency and operation of the ground source heat pump and associated systems. Given that the home includes many non-typical end use loads including a home office, pool, landscape water feature, and other luxury features not accounted for in Building America modeling tools, these end uses were separately monitored to determine their impact on overall energy consumption.

  6. LiDAR-Assisted Multi-Source Program (LAMP for Measuring Above Ground Biomass and Forest Carbon

    Directory of Open Access Journals (Sweden)

    Tuomo Kauranne

    2017-02-01

    Full Text Available Forest measurement for purposes like harvesting planning, biomass estimation and mitigating climate change through carbon capture by forests call for increasingly frequent forest measurement campaigns that need to balance cost with accuracy and precision. Often this implies the use of remote sensing based measurement methods. For any remote-sensing based methods to be accurate, they must be validated against field data. We present a method that combines field measurements with two layers of remote sensing data: sampling of forests by airborne laser scanning (LiDAR and Landsat imagery. The Bayesian model-based framework presented here is called Lidar-Assisted Multi-source Programme—or LAMP—for Above Ground Biomass estimation. The method has two variants: LAMP2 which splits the biomass estimation task into two separate stages: forest type stratification from Landsat imagery and mean biomass density estimation of each forest type by LiDAR models calibrated on field plots. LAMP3, on the other hand, estimates first the biomass on a LiDAR sample using models calibrated with field plots and then uses these LiDAR-based models to generate biomass density estimates on thousands of surrogate plots, with which a satellite image based model is calibrated and subsequently used to estimate biomass density on the entire forest area. Both LAMP methods have been applied to a 2 million hectare area in Southern Nepal, the Terai Arc Landscape or TAL to calculate the emission Reference Levels (RLs that are required for the UN REDD+ program that was accepted as part of the Paris Climate Agreement. The uncertainty of these estimates is studied with error variance estimation, cross-validation and Monte Carlo simulation. The relative accuracy of activity data at pixel level was found to be 14 per cent at 95 per cent confidence level and the root mean squared error of biomass estimates to be between 35 and 39 per cent at 1 ha resolution.

  7. Application on Ground Source Heat Pump in Urumqi%地源热泵在乌鲁木齐的应用研究

    Institute of Scientific and Technical Information of China (English)

    郭亮

    2016-01-01

    地源热泵技术就是充分利用地热能的一种可再生能源的高效、节能、环保型工程系统。阐述地源热泵技术的工作原理,并以新疆电力科学研究院地源热泵工程系统为例,通过运用对季节系统能效比和能源利用系数的计算,分析了地源热泵系统的节能优势;通过与传统燃煤锅炉对环境影响的对比,分析了地源热泵在环境保护方面的优势。通过分析得出,地源热泵系统在主要靠燃煤锅炉供热的乌鲁木齐推广很有意义,可以替代传统的燃煤锅炉,减少原煤的使用,减少污染物的排放,对解决乌鲁木齐冬季空气污染起到很好的作用。%Ground source heat pump technology is a kind of high efficiency, energy saving and environmental protec-tion engineering system of renewable en-ergy sources by the use of geothermal energy. In the study, operating principle of ground source heat pump technology was expounded, ground source heat pump engineering system of Xinjiang electric power research institute was tak-en as an example. Energy-saving advan-tages of ground-source heat pump system was analyzed by the calculation of ener-gy ratio and seasonal system energy effi-ciency ratio. The results showed that there was an important significance on the promotion of ground-source heat pump system in Urumqi. At present, the major heat addition system of Urumqi was still coal-fired boiler, the application of ground-source heat pump system could reduce the use of raw coal and the emissions of pollutants, which had a pos-itive influence on the solution of air pol-lution in winter in Urumqi.

  8. Induced voltage in an open wire

    CERN Document Server

    Morawetz, K; Trupp, A

    2015-01-01

    A puzzle arising from Faraday's law is considered and solved concerning the question which voltage is induced in an open wire feeling a time-varying homogeneous magnetic field. The longitudinal electric field contributes 1/3 and the transverse field 2/3 to the induced voltage. The representation of a homogeneous and time-varying magnetic field implies unavoidably a certain symmetry point or line dependent on the geometry of the source. As a consequence the induced voltage of an open wire is found to be the area covered with respect to the symmetry line or point perpendicular to the magnetic field. This in turn allows to find the symmetry points of a magnetic field source by measuring the voltage of an open wire. We present two exactly solvable models for a symmetry point and for a symmetry line. The results are applicable to open circuit problems and for astrophysical applications.

  9. Forecasting of Corrosion Properties of Steel Wires for Production of Guide Wires for Cardiological Treatment

    Directory of Open Access Journals (Sweden)

    J. Przondziono

    2013-01-01

    Full Text Available The study presents evaluation of the influence of strain in drawing process and of surface modification on resistance to electrochemical corrosion of wires made of stainless steel for production of guide wires used in invasive cardiology. The results of static tensile test enabled us to determine the course of flow curve of wires made of X10CrNi 18-8 steel as well as mathematical form of flow stress function. Resistance to electrochemical corrosion was evaluated on the ground of registered anodic polarisation curves by means of potentiodynamic method. The tests were performed in solution simulating human blood on samples that were electrolytically polished and samples that were polished and then chemically passivated. Exemplary anodic polarisation curves were given. It was proved that with the applied strain, corrosion properties decrease. It was found that chemical passivation improves wire corrosion characteristics. Statistical analysis showed that there is a significant dependence between corrosion properties (polarisation resistance Rp and strain ε applied in drawing process. Functions that present the change Rp=f(ε were selected. The issue is of importance to guide wire manufacturers because application of the suggested methodology will enable us to forecast corrosion characteristics of wire with the required strength drawn with the applied strain.

  10. System and method for evaluating a wire conductor

    Science.gov (United States)

    Panozzo, Edward; Parish, Harold

    2013-10-22

    A method of evaluating an electrically conductive wire segment having an insulated intermediate portion and non-insulated ends includes passing the insulated portion of the wire segment through an electrically conductive brush. According to the method, an electrical potential is established on the brush by a power source. The method also includes determining a value of electrical current that is conducted through the wire segment by the brush when the potential is established on the brush. The method additionally includes comparing the value of electrical current conducted through the wire segment with a predetermined current value to thereby evaluate the wire segment. A system for evaluating an electrically conductive wire segment is also disclosed.

  11. Discussion on possibilities of taking ground ice in permafrost as water sources on the Qinghai-Tibet Plateau during climate warming

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Large amounts of ground ice are born with permafrost on the Qinghai-Tibet Plateau.Degradation of permafrost resulted from the climate warming will inevitably lead to melting of ground ice.The water released from the melting ground ice enters hydrologic cycles at various levels,and changes regional hydrologic regimes to various degrees.Due to difficulties in monitoring the perma-frost-degradation-release-water process,direct and reliable evidence is few.The accumulative effect of releasing water,however,is remarkable in the macro-scale hydrologic process.On the basis of the monitoring results of water-levels changes in some lakes on the Qinghai-Tibet Plateau,and combined with the previous results of the hydrologic changing trends at the regional scale,the authors preliminarily discussed the possibilities of the degrading permafrost on the Qinghai-Tibet Plateau as a potential water source during climate warming.

  12. Nonlinear electron transport in normally pinched-off quantum wire

    OpenAIRE

    Novoselov, K.S.; Dubrovskii, Yu. V.; Sablikov, V. A.; Ivanov, D. Yu.; Vdovin, E. E.; Khanin, Yu N.; Tulin, V. A.; Esteve, D.; Beaumont, S.

    2000-01-01

    Nonlinear electron transport in normally pinched-off quantum wires was studied. The wires were fabricated from AlGaAs/GaAs heterostructures with high-mobility two-dimensional electron gas by electron beam lithography and following wet etching. At certain critical source-drain voltage the samples exhibited a step rise of the conductance. The differential conductance of the open wires was noticeably lower than e^2/h as far as only part of the source-drain voltage dropped between source contact ...

  13. Thermal Model of a Current-Carrying Wire in a Vacuum

    Science.gov (United States)

    Border, James

    2006-01-01

    A computer program implements a thermal model of an insulated wire carrying electric current and surrounded by a vacuum. The model includes the effects of Joule heating, conduction of heat along the wire, and radiation of heat from the outer surface of the insulation on the wire. The model takes account of the temperature dependences of the thermal and electrical properties of the wire, the emissivity of the insulation, and the possibility that not only can temperature vary along the wire but, in addition, the ends of the wire can be thermally grounded at different temperatures. The resulting second-order differential equation for the steady-state temperature as a function of position along the wire is highly nonlinear. The wire is discretized along its length, and the equation is solved numerically by use of an iterative algorithm that utilizes a multidimensional version of the Newton-Raphson method.

  14. 3D Temperature Field Simulation of Wire Electrode in WEDM Under the Moving Heat Source%移动热源作用下电火花线切割加工电极丝三维温度场模拟

    Institute of Scientific and Technical Information of China (English)

    杨晓冬; 滕庆

    2011-01-01

    The high-speed and medium-speed wire electrical discharge machines which are originally developed in China are playing an important role in mold making. However, the wire electrode wear is a universal problem in the machining process because the wire electrode is used repeatedly. Considering the relative motion between the wire electrode and the workpiece, the heat transfer model of wire electrode under moving heat source was established, and the three-dimensional temperature field of wire electrode was simulated in single pulse discharge by FEM. The results indicated that the size of the melted zone along the wire electrode length direction increased remarkably while the depth size of the melted zone reduced apparently when the wire running speed increased. It can be concluded that the high relative speed between the wire electrode and the workpiece is beneficial to reduce the wire electrode wear in radial direction. Furthermore, when the wire running speed up to a certain value, the discharge column will slide over the wire electrode surface before the wire material reaches its melting point, thus the melting and ablation of the wire electrode material don' t happen, which can almost realize no wire electrode wear.%往复走丝和“中走丝”电火花线切割机床是中国独创的电加工设备,在模具制造等行业发挥着重要作用.由于其电极丝是重复使用的,因此电极丝损耗是普遍存在的问题.在电极丝与工件之间相对运动的情况下,建立了移动热源条件下的电极丝传热模型,通过有限元分析对单脉冲放电条件下电极丝表面温度场进行了三维仿真,发现当走丝速度增加时电极丝熔融区沿电极丝长度方向的尺寸明显加长,但熔融区深度方向尺寸明显减小,从而得出电极丝与工件之间的高速相对运动有利于减少电极丝半径方向损耗的结论.当走丝速度增加到一定值时,可使放电通道在电极丝材料达到熔点之前滑过

  15. Characterisation of Seasonal Temperature Variation in a Shallow, Urban Aquifer: Implications for the Sustainable Development of Ground Source Heating Systems

    Science.gov (United States)

    Patton, Ashley M.; Farr, Gareth J.; Boon, David P.; James, David R.

    2017-04-01

    Groundwater thermally enhanced by the Urban Heat Island effect can be utilised by ground source heating systems (GSHSs). However, the near subsurface is subject to seasonal temperature variation reflected in shallow groundwater that can differ by several degrees throughout the year. To sustainably manage the near surface thermal resource an understanding of factors which control variation in groundwater temperature and how these are transmitted through the aquifer is needed. We show that even in relatively small urban areas (Cardiff, U.K., situated on a shallow gravel aquifer) the Zone of Seasonal Fluctuation (ZSF) can vary in depth by 8m. GSHSs are more efficient if they are sited below the ZSF, where temperatures are more stable. In Spring 2014, 48 groundwater monitoring boreholes were profiled at a 1m resolution to measure groundwater temperature across Cardiff. These were reprofiled that Autumn and compared to the Spring temperatures, defining the ZSF. The average depth to the base of the ZSF was 9.5mbgl but ranged from 7.1-15.5mbgl. The amplitude of the differences between Spring and Autumn temperatures also varied. To better understand the high spatial variability 60 boreholes were instrumented with in situ temperature loggers, recording at half-hourly intervals. The first year's data revealed the amplitudes of temperature variation within boreholes with loggers at similar depths were not always consistent. It was also noted that lag times between air temperature and groundwater temperature were not uniform across the sites. The data also showed that where gravels occurred at shallower depths the ZSF tended to be shallower and lag times shorter. The wide spatial variability of the ZSF may be partially explained by differing landuse. Those boreholes in open, grassed areas showed a deeper ZSF than those in built-up areas but built-up areas generally showed the greatest variation between Spring and Autumn temperature profiles, suggesting heat loss from buildings

  16. Bird on a (live) wire

    Energy Technology Data Exchange (ETDEWEB)

    Farr, M.

    2003-09-30

    Bird mortality as a result of contact with power lines is discussed. U. S. statistics are cited, according to which 174 million birds annually die as a result of contact with power lines, specifically when birds touch two phases of current at the same time. Raptors are particularly vulnerable to power-line electrocution due to their habit of perching on the highest vantage point available as they survey the ground for prey. Hydro lines located in agricultural areas, with bodies of water on one side and fields on the other, also obstruct flight of waterfowl as dusk and dawn when visibility is low. Various solutions designed to minimize the danger to birds are discussed. Among these are: changing the configuration of wires and cross arms to make them more visible to birds in flight and less tempting as perches, and adding simple wire markers such as flags, balloons, and coloured luminescent clips that flap and twirl in the wind. There is no evidence of any coordinated effort to deal with this problem in Ontario. However, a report is being prepared for submission to Environment Canada outlining risks to birds associated with the growing number of wind turbine power generators (negligible compared with power lines and communications towers), and offering suggestions on remedial measures. The Fatal Light Awareness Program (FLAP) also plans to lobby the Canadian Wildlife Service to discuss the possibility of coordinating efforts to monitor, educate about and ultimately reduce this form of bird mortality.

  17. Cavitation during wire brushing

    Science.gov (United States)

    Li, Bo; Zou, Jun; Ji, Chen

    2016-11-01

    In our daily life, brush is often used to scrub the surface of objects, for example, teeth, pots, shoes, pool, etc. And cleaning rust and stripping paint are accomplished using wire brush. Wire brushes also can be used to clean the teeth for large animals, such as horses, crocodiles. By observing brushing process in water, we capture the cavitation phenomenon on the track of moving brush wire. It shows that the cavitation also can affect the surface. In order to take clear and entire pictures of cavity, a simplified model of one stainless steel wire brushing a boss is adopted in our experiment. A transparent organic tank filled with deionized water is used as a view box. And a high speed video camera is used to record the sequences. In experiment, ambient pressure is atmospheric pressure and deionized water temperature is kept at home temperature. An obvious beautiful flabellate cavity zone appears behind the moving steel wire. The fluctuation of pressure near cavity is recorded by a hydrophone. More movies and pictures are used to show the behaviors of cavitation bubble following a restoring wire. Beautiful tracking cavitation bubble cluster is captured and recorded to show.

  18. Copper wire bonding

    CERN Document Server

    Chauhan, Preeti S; Zhong, ZhaoWei; Pecht, Michael G

    2014-01-01

    This critical volume provides an in-depth presentation of copper wire bonding technologies, processes and equipment, along with the economic benefits and risks.  Due to the increasing cost of materials used to make electronic components, the electronics industry has been rapidly moving from high cost gold to significantly lower cost copper as a wire bonding material.  However, copper wire bonding has several process and reliability concerns due to its material properties.  Copper Wire Bonding book lays out the challenges involved in replacing gold with copper as a wire bond material, and includes the bonding process changes—bond force, electric flame off, current and ultrasonic energy optimization, and bonding tools and equipment changes for first and second bond formation.  In addition, the bond–pad metallurgies and the use of bare and palladium-coated copper wires on aluminum are presented, and gold, nickel and palladium surface finishes are discussed.  The book also discusses best practices and re...

  19. Ground source heat pump technology in colleges and universities to explore application%地源热泵技术在高校的探索应用

    Institute of Scientific and Technical Information of China (English)

    龚伟申

    2011-01-01

    Focuses on the Nanjing Railway,Suzhou Vocational and Technical College Campus Library case of ground-source heat pump systems engineering and operational effectiveness analysis that the ground-source heat pump air-conditioning and domestic water in the school application is feasible,energy-efficient,economy is also clear is worthy of dissemination and application.%介绍了南京铁道职业技术学院苏州校区图书馆地源热泵系统工程案例及运行效果分析,认为土壤源热泵在学校空调及生活用水的应用是可行的、节能的,经济性也是明显的,值得推广应用.

  20. A ground water source heat pump for the air-conditioning of a supermarket; Une PAC sur nappe phreatique pour climatiser un hypermarche

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2002-04-01

    A thermodynamical solution involving a ground water source heat pump and 19 roof top air-conditioners has been retained for the air-conditioning of a 41000 m{sup 2} supermarket of Colmar (Alsace, France). The supermarket is also equipped with a computer-monitored refrigeration system for the food products and a centralized technical management for the optimization of the installation operation. (J.S.)

  1. Composite ground source heat pump used in scattered oilfield%复合地源热泵在油田边零井中的应用

    Institute of Scientific and Technical Information of China (English)

    刘伟; 杨鹏; 侯静

    2012-01-01

    In the Remote areas, oil is stored in storage tanks, and needed to be heated in order to output. Compared with fuel, gas boilers and electric heating system, ground source heat pump heating system has the features as safe, energy saving, environmentally friendly. But a separate ground source heat pump sys- tem only take the heat from soil, not release heat to the soil. To overcome this shortcoming the paper pro- poses solar--assisted ground-source heat pump system. Through the use of trnsys software simulation, it is proved that this system is feasible, and should be promoted.%油田边零井中的原油储存在储油罐中,需要加热才能输出,地源热泵加热系统较燃油、燃气锅炉和电加热系统,具有安全,节能,环保的特点,但是单独地源热泵系统地下地埋管只取热不放热,为了克服这个缺点,提出了太阳能辅助地源热泵系统,通过运用trnsys软件模拟,证明此系统用于油田边零井是可行的,值得推广的。

  2. 地源热泵的应用与技术性分析%Application and Technical Analysis of Ground Source Heat Pumps

    Institute of Scientific and Technical Information of China (English)

    刘孝刚

    2015-01-01

    Ground source heat pump is a shallow underground resources of both cooling and heating functions heat pump system. The unit has the advantages of easy maintenance, energy saving, no secondary environment pollution. Taking a ground source heat pump works as a technical analysis examples, the number of options the air conditioning units were analyzed and compared. The development prospects of ground-source heat pump system were discussed.%地源热泵是一种利用地下浅层资源兼有制冷制热功能的热泵空调系统,其机组维护方便、节能环保,对环境没有二次污染。文中通过对地源热泵工程实例的技术性分析,对多个方案的空调机组进行了分析比较,对地源热泵系统的发展前景进行了展望。

  3. 地源热泵系统节能潜力分析%Analysis of energy saving potential of ground source heat pump system

    Institute of Scientific and Technical Information of China (English)

    李新付

    2015-01-01

    在三星级绿色公共建筑中采用地源热泵系统供冷供热,可以在建筑全寿命期内最大限度地节约能源、保护环境减少污染。本文通过对安阳市民之家(三星绿建)采用的地下室地源热泵进行定性定量分析,阐明地源热泵系统的巨大节能空间。%The use of ground source heat pump system for cold heating in the three star green building, can save energy and protect the environment to reduce pollution in the whole life period. In this paper, a qualitative and quantitative analysis of the ground source heat pump is carried out, and the great energy saving space of the ground source heat pump system is expounded.

  4. Source and ground-motion parameters of the 2011 Lorca earthquake; Parametros de la fuente y del movimiento del suelo del terremoto de Lorca de 2011

    Energy Technology Data Exchange (ETDEWEB)

    Alguacil de la Blanca, G.; Vidal Sanchez, F.; Stich, D.; Mancilla Perez, F. L.; Lopez Comino, J. A.; Morales Soto, J.; Navarro Bernal, M.

    2012-07-01

    113 events of the Lorca seismic series has been relocated by using Double difference algorithm and data from both temporary and permanent seismic networks. Relocations yield shallow hypo central distribution of aftershocks with a {approx}5 km long, NE-SW trending, placed SW of the mainshock, suggesting a SW propagating rupture along the Alhama de Murcia fault. Similar oblique reverse faulting mechanism has been obtained for three largest events. Source parameters of these three earthquakes have been estimated. Horizontal ground motion was estimated at 11 city points whose local structure was known by SPAC experiments. A set of ground motion parameters (PGA, PGV, AI, CAV, SI, SA and SV) here calculated, have higher values at these points respect to the ones at LOR station. All parameter values are also above the expected values for Euro -Mediterranean earthquakes with local intensity VIII (EMS). Nevertheless, SD values are unusually short and less than the reference ones. Higher values of the response spectra of acceleration and velocity are given for periods of less than 0.7 s, with maximum spectral acceleration at 0.15 s and velocity at 0.5 s. The elastic input energy spectrum is well connected to the shake destructiveness in each place. Equivalent velocity > 60 cm/s is found in almost all sites and > 100 cm/s (for periods 0.3 to 0.6 s) in someone. Factors such as proximity, and focal mechanism and ground response characteristics explain the high ground motion parameter values obtained in Lorca sites and show the great influence of the source and site conditions on the characteristics of strong ground motion in the vicinity of the rupture. (Author) 68 refs.

  5. 地源热泵的研究与应用现状%Research and Application Status of Ground Source Heat Pump

    Institute of Scientific and Technical Information of China (English)

    武曈; 刘钰莹; 董喆; 方莹; 刘益才

    2014-01-01

    The paper starts with a brief introduction to the classification and working principle of ground source heat pump (GSHP) in three aspects of ground coupled heat pump system, ground water source heat pump system, surface water source heat pump system, and a brief overview of these three ground source heat pump systems is illustrated on the basis of the features and quality. Based on the research and application at home and abroad, new trends and new research progress of ground source heat pump in twenty-first century are mainly analyzed, i. e. using modern means to analysis and improve the water carrying capacity and the performance of the pump system. At the same time, the concise examples about the combination of the new technology and the original technology of heat pump are listed in the paper, such as the summary of solar, ice storage and waste heat utilization. A conclusion can be drawn that notable advantages of GSHP with respects to energy saving and environment protection must lead to a wide application prospect of GSHP system in China.%本文从土壤耦合热泵系统、地下水地源热泵系统、地表水地源热泵系统三个方面,介绍了地源热泵的分类及工作原理,并在分类的基础上对三大地源热泵系统进行了简要的概述,说明其特点和优劣。在综合国内外研究应用的基础上,重点总结分析了21世纪地源热泵的研究进展及新研究趋势--针对水体承载能力、热泵系统的效能等利用现代手段进行分析和提高。同时,本文对新技术与热泵原有技术的结合进行了简明例举,列举出与太阳能、冰蓄冷、余热利用相关的概要。通过本文表明地源热泵在节能环保方面的显著优势,也证明其在我国拥有广泛的应用前景。

  6. Hydrogeologic Evaluation of a Ground-Source Cooling System at the BSF/CSF on the Battelle Campus: Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Freedman, Vicky L.; Mackley, Rob D.; Waichler, Scott R.; Horner, Jacob A.; Moon, Thomas W.; Newcomer, Darrell R.; DeSmet, Darrell J.; Lindsey, K. A.; Porcello, J. J.

    2010-05-12

    This report documents both the field characterization activities and the numerical modeling effort at the BSF/CSF site to determine the viability of an open-loop ground source heat pump (GSHP). The primary purpose of the integrated field and modeling study was to determine far-field impacts related to a non-consumptive use water right for the well field containing four extraction and four injection wells. In the field, boreholes were logged and used to develop the geologic conceptual model. Hydraulic testing was performed to identify hydraulic properties and determine sustainable pumping rates. Estimates of the Ringold hydraulic conductivity (60-150 m/d) at the BSF/CSF site were consistent with the local and regional hydrogeology as well as estimates previously published by other investigators. Sustainable pumping rates at the extraction wells were variable (100 – 700 gpm), and confirmed field observations of aquifer heterogeneity. Field data were used to develop a numerical model of the site. Simulations assessed the potential of the well field to impact nearby contaminant plumes, neighboring water rights, and the thermal regime of nearby surface water bodies. Using steady-state flow scenarios in conjunction with particle tracking, a radius of influence of 400–600 m was identified around the well field. This distance was considerably shorter than the distance to the closest contaminant plume (~1.2 km northwest to the DOE Horn Rapids Landfill) and the nearest water right holder (~1.2 km southeast to the City of Richland Well Field). Results demonstrated that current trajectories for nearby contaminant plumes will not be impacted by the operation of the GSHP well field. The objective of the energy transport analysis was to identify potential thermal impacts to the Columbia River under likely operational scenarios for the BSF/CSF well field. Estimated pumping rates and injection temperatures were used to simulate heat transport for a range of hydraulic

  7. Analyzing a Vibrating Wire Transducer using Coupled Resonator Circuits

    Directory of Open Access Journals (Sweden)

    POP, S.

    2015-08-01

    Full Text Available This paper intends to be an approach on the vibrating wire transducer from the perspective of the necessary rules used for a correct measurement procedure. There are several studies which analyze the vibrating wire transducer as a mechanical system. However, a comparative time-domain analysis between the mechanical and the electrical model is lacking. The transducer analysis is based on a theoretical analysis of the equivalent circuit, on both excitation and response time intervals. The electrical model consists of two magnetic coupled resonating circuits. When connected to an excitation source, there will be an energy transfer from the coil to the wire. The maximum energy transfer will occur at the vibrating wire's frequency of resonance. Using the transient regime analysis, it has been proven that, in the response time interval - when the wire vibrates freely, the current through the circuit that models the wire describes the oscillating movement of the wire. A complex signal is obtained, that contains both coil's and wire's frequencies of resonance, strongly dependent with theirs parasitic elements. The mathematical analysis highlights the similarity between mechanical and electrical model and the procedures in order to determine the wire frequency of resonance from the output signal.

  8. Command Wire Sensor Measurements

    Science.gov (United States)

    2012-09-01

    ground penetrating radar (From [10]) B. GROUND PENETRATING RADAR Buried landmines and IED detection using electromagnetic induction (EMI) techniques is...5  A.  EXISTING DETECTION SYSTEMS ...........................................................5  B.  GROUND PENETRATING RADAR ...3.  Husky mine detection vehicle with ground penetrating radar (From [10]) .......6  Figure 4.  Propagation losses plotted against frequency for

  9. The summary of heat transfer performance influential analysis of Ground Source Heat Pump' s vertical ground heat exchangers%地源热泵垂直地埋管传热性能影响因子分析

    Institute of Scientific and Technical Information of China (English)

    赵丽博; 段飞; 李政

    2011-01-01

    The design of Ground Source Heat Pump' s (GSHP) ground heat exchanger is the key and difficulty of GSHP system' s engineering applications. Combining the research results at home and abroad in recent years, this article analysis completely the influence of backfill material, buried tube depth, the flow in pipe and other factors on the performance of ground heat exchangers, aiming at providing the basis for engineering applications and scientific research.%地源热泵地下换热器的设计是地源热泵系统工程应用的关键和难点,结合近几年国内外的研究成果,全面分析了管内流量、埋管深度、回填材料等因子对地埋管传热性能的影响,以期为工程应用及科学研究提供依据。

  10. Polyurethane spray coating of aluminum wire bonds to prevent corrosion and suppress resonant oscillations

    CERN Document Server

    Izen, Joseph; The ATLAS collaboration; Kurth, Matthew Glenn

    2015-01-01

    Unencapsulated aluminum wedge wire bonds are common in particle-physics pixel and strip detectors. Industry-favored bulk encapsulation is eschewed due to the range of operating temperatures and radiation. Wire bond failures are a persistent, source of tracking detector failure Unencapsulated bonds are vulnerable to condensation-induced corrosion, particularly when halides are present. Oscillations from periodic Lorenz forces are documented as another source of wire bond failure. Spray application of polyurethane coatings, performance of polyurethane-coated wire bonds after climate chamber exposure, and resonant properties of PU-coated wire bonds and their resistance to periodic Lorenz forces will be described.

  11. 2D ground motion at a soft viscoelastic layer/hard substratum site in response to SH cylindrical seismic waves radiated by deep and shallow line sources

    CERN Document Server

    Wirgin, A; Wirgin, Armand

    2004-01-01

    We show, essentially by theoretical means, that for a site with the chosen simple geometry and mechanical properties (horizontal, homogeneous, soft viscoelastic layer of infinite lateral extent overlying, and in welded contact with, a homogeneous, hard elastic substratum of half-infinite radial extent, shear-horizontal motion): 1) coupling to Love modes is all the weaker the farther the seismic source (modeled as a line, assumed to lie in the substratum) is from the lower boundary of the soft layer, 2) for a line source close to the lower boundary of the soft layer, the ground response is characterized by possible beating phenomena, and is of significantly-longer duration than for excitation by cylindrical waves radiated by deep sources. Numerical applications of the theory show, for instance, that a line source, located 40m below the lower boundary of a 60m thick soft layer in a hypothetical Mexico City-like site, radiating a SH pulse of 4s duration, produces substantial ground motion during 200s, with marke...

  12. EVALUATION OF INDUCTANCE WITH ELECTRICAL WIRES

    Directory of Open Access Journals (Sweden)

    V. Kudry

    2016-08-01

    Full Text Available In this paper proved the possibility of developing passive electronic inductive elements based replace metal wire that is wound inductor, the wire is made of electret. The relative permeability of the electret S  10 000, several orders of magnitude greater than the permeability of conventional insulation materials, i < 10, resulting current in the wire acquires properties bias current. The essence of innovation is to replace the source of of magnetic induction flow that pervades the core of the coil. According to the theory of electrodynamics, current bias, in contrast to conduction current, generated no movement of charge along the wire, but the change of the charge in the local volume.Equivalence bias current and conduction current is manifested in the possibility of forming a magnetic field. The flow through magnetic induction coil core regardless of the current it generates, creates voltage at its ends.The paper also shows the numeric characteristics that determine the effective frequency range, specified the reason why electric a wire with і < 10 can not generate magnetic flux through the core and serve as a passive reactive component.

  13. Distribution of wire deformation within strands of wire ropes

    Institute of Scientific and Technical Information of China (English)

    MA Jun; GE Shi-rong; ZHANG De-kun

    2008-01-01

    Using ANSYS software, we developed a modeling program for several kinds of wire ropes with metal cores and built a geometric model for the 6x19 IWS wire rope. Through proper grid partitioning, a finite element model for calculating the deformation of wire rope was obtained. Completely constraining one end of the wire rope and applying an axial force to the other end, we established the boundary conditions for solving the model. In addition, we numerically simulated the stress and deformation of the wire, obtaining the deformation distribution of each wire within the wire rope under different laying directions.At the end, a tensile test of the 6x19 IWS wire rope was carried out and the results of simulation and experiment compared.

  14. Electric wiring domestic

    CERN Document Server

    Coker, A J

    1992-01-01

    Electric Wiring: Domestic, Tenth Edition, is a clear and reliable guide to the practical aspects of domestic electric wiring. Intended for electrical contractors, installation engineers, wiremen and students, its aim is to provide essential up to date information on modern methods and materials in a simple, clear, and concise manner. The main changes in this edition are those necessary to bring the work into line with the 16th Edition of the Regulations for Electrical Installations issued by the Institution of Electrical Engineers. The book begins by introducing the basic features of domestic

  15. Wiring and lighting

    CERN Document Server

    Kitcher, Chris

    2013-01-01

    Wiring and Lighting provides a comprehensive guide to DIY wiring around the home. It sets out the regulations and legal requirements surrounding electrical installation work, giving clear guidelines that will enable the reader to understand what electrical work they are able to carry out, and what the testing and certification requirements are once the work is completed. Topics covered include: Different types of circuits; Types of cables and cable installation under floors and through joists; Isolating, earthing and bonding; Accessory boxes and fixings; Voltage bands; Detailed advice on safe

  16. Polaron in a quasi 1D cylindrical quantum wire

    Directory of Open Access Journals (Sweden)

    I.Nsangou

    2005-01-01

    Full Text Available Polaron states in a quasi 1D cylindrical quantum wire with a parabolic confinement potential are investigated applying the Feynman variational principle. The effect of the wire radius on the polaron ground state energy level, the mass and the Fröhlich electron-phonon-coupling constant are obtained for the case of a quasi 1D cylindrical quantum wire. The effect of anisotropy of the structure on the polaron ground state energy level and the mass are also investigated. It is observed that as the wire radius tends to zero, the polaron mass and energy diverge logarithmically. The polaron mass and energy differ from the canonical strong-coupling behavior by the Fröhlich electron-phonon coupling constant and the radius of the quasi 1D cylindrical quantum wire that are expressed through a logarithmic function. Moreover, it is observed that the polaron energy and mass for strong coupling for the case of the quasi 1D cylindrical quantum wire are greater than those for bulk crystals. It is also observed that the anisotropy of the structure considerably affects both the polaron ground state energy level and the mass. It is found that as the radius of the cylindrical wire reduces, the regimes of the weak and intermediate coupling polaron shorten while the region of the strong coupling polaron broadens and extends into those of the weak and intermediate ones. Analytic expressions for the polaron ground state energy level and mass are derived for the case of strong coupling polarons.

  17. The clinical value of CT guidance Hook-wire positioning thoracoscopic surgery for ground-glass opacity lung nodules%术前CT引导下Hook-wire定位胸腔镜切除肺毛玻璃样结节临床研究

    Institute of Scientific and Technical Information of China (English)

    邓俊; 仲宁; 陈文

    2016-01-01

    目的:探讨CT引导下Hook-wire术前定位肺磨玻璃样结节(GGO)在胸腔镜切除术中的应用。方法:25例肺GGO患者均术前行Hook-wire定位,行胸腔镜肺楔形切除术。根据术中冰冻病理结果决定下一步治疗方式。结果:肺GGO直径为(11.48±3.50)mm,距离壁层胸膜(16.52±5.98)mm。CT引导肺GGO Hook-wire定位均成功,定位时间(15.04±3.38)min,出现微量气胸5例(占20%),均不需放置引流管,1例出现少许肺实质出血(占4.00%),无一例出现定位针脱落,实施胸腔镜肺楔形切除100%,其中12例单纯行胸腔镜肺楔形切除手术时间为(21.67±3.94)min,13例为浸润性腺癌,行胸腔镜肺叶或是肺段切除及淋巴结清扫术,手术时间为(58.84±12.01)min。结论:术前CT引导下Hook-wire定位是一种安全可靠且容易掌握的临床技术,降低了手术时间,并发症少,值得临床推广应用。%Objective: To evaluate the clinical application of guidance Hook-wire positioning for ground-glass opacity before video-assisted thoracoscopic resection.Methods: Preoperative location of 25 patients with ground-glass opacity lung nodules was performed using CT-guided Hook-wire technique. Video assisted tho-racic surgery (VATS) pulmonary wedge resection was adopted. According to the result of intraoperative frozen pathology, the next mode of operation was adopted.Results: GGO diameter (11.48±3.50) mm, diatance from the parietal pleura (16.52±5.98) mm. Twenty ifve patients were successfully located. The mean procedure time for preoperative CT-guided Hook-wire location was (15.04±3.38) min. 5 patients had micro pneumothroax after positioning. The chest tube drainage was not required. One patient had minimal needle tract parenchymal hemor-rhages. No one occured migration and fall out of the hookwire. VATS wedge resection surgery successful rate was 100%. Twelve cases of pure thoracoscopy pulmonary wedge

  18. Correlating Meteorological, Satellite, and Ground Sampling Data to Determine Source of PM2.5 at Bagram Airfield (BAF), Afghanistan

    Science.gov (United States)

    2015-07-08

    Assistant Professor, Department of Preventive Medicine and Biostatistics Particulate matter (PM) is a mixture of airborne liquid droplets and solid...cadmium), dioxins (PCDDs), furans (PCDFs) and particulate matter (PM) [2]. The PM varies in size and the mixture of liquid droplets and solid particles...occur when cold air is trapped under a layer of warm air which can occur when the ground cools rapidly on a cold clear night or when cold air from

  19. Monitoring actual performance of ground source heat pump system using GPRS-based data transmission:A case analysis in Tangshan

    Institute of Scientific and Technical Information of China (English)

    杜红普; 孔祥飞; 李敏; 齐承英

    2015-01-01

    The energy efficiency monitoring is an essential precondition for ground source heat pump system’s controlling and energy saving operation. Based on the data monitoring applied in the school building, this work is focused on the parameters acquisition and operation analysis of the GSHP system in Tangshan. Results show the average COPs (coefficient of performance) are 2.85 and 2.70 in summer and winter, respectively, and heat(cold) unbalance underground existed after whole year operation. The analysis of data also indicates that the direct borehole air-conditioning saved some power consumption obviously in the early stage of summer and energy saving of the GSHP system depended remarkably on its operation and management level. Besides the observation points of ground temperature are laid for a large-scale GSHP system, and the hydraulic balance of the pipes group needs to be concerned specially in safeguarding better reliability.

  20. Practical wiring in SI units

    CERN Document Server

    Miller, Henry A

    2013-01-01

    Practical Wiring, Volume 1 is a 13-chapter book that first describes some of the common hand tools used in connection with sheathed wiring. Subsequent chapters discuss the safety in wiring, cables, conductor terminations, insulating sheathed wiring, conductor sizes, and consumer's control equipments. Other chapters center on socket outlets, plugs, lighting subcircuits, lighting accessories, bells, and primary and secondary cells. This book will be very valuable to students involved in this field of interest.

  1. Estimation of ground water resources in exploration of water source fields in alluvial plain%冲积平原水源地资源量计算

    Institute of Scientific and Technical Information of China (English)

    冯斌

    2012-01-01

    Estimation of water resources is very important in the exploration of water source field. Base on estimation of the ground water resources of Xiao Li-zhuang water source field in new municipal area of Yongcheng, Henan province, the content and requirement of calculating the groundwater resources for the water source field of the alluvial plain are systematically expounded in this paper. Recharge of ground water includes infiltration of precipitation water and well irrigation. Groundwater excretion includes evaporation, pumping, lateral runoff, and lateral infiltration of surface water.%水源地资源量计算在水源地勘察中非常重要.本文结合河南省永城市新城水厂小李庄水源地的地下水资源量计算实践,系统地阐述了冲积平原水源地地下水资源量计算的内容及要求.其中,地下水补给量包括大气降水入渗补给量和农业井灌回渗补给量.地下水排泄量包括地下水的蒸发量、开采量、侧向径流排泄量和地表水侧渗排泄量.

  2. 3D Wire 2015

    DEFF Research Database (Denmark)

    Jordi, Moréton; F, Escribano; J. L., Farias

    This document is a general report on the implementation of gamification in 3D Wire 2015 event. As the second gamification experience in this event, we have delved deeply in the previous objectives (attracting public areas less frequented exhibition in previous years and enhance networking) and ha......, improves socialization and networking, improves media impact, improves fun factor and improves encouragement of the production team....

  3. One-wire thermocouple

    Science.gov (United States)

    Goodrich, W. D.; Staimach, C. J.

    1977-01-01

    Nickel alloy/constantan device accurately measures surface temperature at precise locations. Device is moderate in cost and simplifies fabrication of highly-instrumented seamless-surface heat-transfer models. Device also applies to metal surfaces if constantan wire has insulative coat.

  4. Sound propagation over screened ground under upwind conditions

    DEFF Research Database (Denmark)

    Rasmussen, Karsten Bo

    1996-01-01

    in the frequency domain. The meteorological data representing the wind conditions have been determined by means of hot-wire anemometry in positions on both sides of the screen as well as directly over the screen. The theoretical model used for comparison is a hybrid approach. The sound field without a barrier......A screen on an absorbing ground is investigated experimentally and theoretically under upwind conditions. The experimental data are the result of scale model experiments in a 1:25 scale model. The sound propagation is measured using a triggered spark source with signal spectrum averaging...

  5. REMEDY OF WIRE LAG IN WIRE ELECTRICAL DISCHARGE MACHINING (WEDM

    Directory of Open Access Journals (Sweden)

    S. K. SINHA

    2010-12-01

    Full Text Available WEDM is extensively used these days for generating complex geometries with tight tolerances on difficult-tomachine materials. Therefore, demand for improvement in precision has been ever increasing. The main source of inaccuracy is wire-lag, the cause and effect of which is well-known. Research has been going on to overcome this drawback. So far, the techniques suggested for improvement in accuracy are, in general, based on monitoring the machining process at hardware-level, which is not only tedious but involves extra expenditure also. In the present paper, a software approach for improvement in accuracy is described, which does not require any additional investment on the machine, and still gives very good results.

  6. Percentage of probability of nonpoint-source nitrate contamination of recently recharged ground water in the High Plains aquifer

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This raster data set represents the percentage of probability of nonpoint-source nitrate contamination (greater than the proposed background concentration of 4...

  7. Reusable Hot-Wire Cable Cutter

    Science.gov (United States)

    Pauken, Michael T.; Steinkraus, Joel M.

    2010-01-01

    During the early development stage of balloon deployment systems for missions, nichrome wire cable cutters were often used in place of pyro-actuated cutters. Typically, a nichrome wire is wrapped around a bundle of polymer cables with a low melting point and connected to a relay-actuated electric circuit. The heat from the nichrome reduces the strength of the cable bundle, which quickly breaks under a mechanical load and can thus be used as a release mechanism for a deployment system. However, the use of hand-made heated nichrome wire for cutters is not very reliable. Often, the wrapped nichrome wire does not cut through the cable because it either pulls away from its power source or does not stay in contact with the cable being cut. Because nichrome is not readily soldered to copper wire, unreliable mechanical crimps are often made to connect the nichrome to an electric circuit. A self-contained device that is reusable and reliable was developed to sever cables for device release or deployment. The nichrome wire in this new device is housed within an enclosure to prevent it from being damaged by handling. The electric power leads are internally connected within the unit to the nichrome wire using a screw terminal connection. A bayonet plug, a quick and secure method of connecting the cutter to the power source, is used to connect the cutter to the power leads similar to those used in pyro-cutter devices. A small ceramic tube [0.25-in. wide 0.5-in. long (.6.4-mm wide 13-mm long)] houses a spiraled nichrome wire that is heated when a cable release action is required. The wire is formed into a spiral coil by wrapping it around a mandrel. It is then laid inside the ceramic tube so that it fits closely to the inner surface of the tube. The ceramic tube provides some thermal and electrical insulation so that most of the heat generated by the wire is directed toward the cable bundle in the center of the spiral. The ceramic tube is cemented into an aluminum block, which

  8. Clinical Study of Intra-operative Computed Tomography Guided Localization with A Hook-wire System for Small Ground Glass Opacities in Minimally Invasive Resection%CT引导下Hook-w ire定位肺磨玻璃样微小结节微创切除的临床研究

    Institute of Scientific and Technical Information of China (English)

    初向阳; 侯晓彬; 张连斌; 薛志强; 任志鹏; 温佳新; 刘毅; 马克峰; 孙玉鹗

    2014-01-01

    Background and objective Localization of pulmonary ground glass small nodule is the technical dif-ficulty of minimally invasive operation resection. The aim of this study is to evaluate the value of intraoperative computed tomography (CT)-guided localization using a hook-wire system for small ground glass opacity (GGO) in minimally invasive resection, as well as to discuss the necessity and feasibility of surgical resection of small GGOs (<10 mm) through a minimally invasive approach.MethodshTe records of 32 patients with 41 small GGOs who underwent intraoperative CT-guided double-thorn hook wire localization prior to video-assisted thoracoscopic wedge resection from October 2009 to October 2013 were retrospectively reviewed. All patients received video-assisted thoracoscopic surgery (VATS) within 10 min atfer wire localiza-tion. hTe effcacy of intraoperative localization was evaluated in terms of procedure time, VATS success rate, and associated complications of localization.Results A total of 32 patients (15 males and 17 females) underwent 41 VATS resections, with 2 simultaneous nodule resections performed in 3 patients, 3 lesion resections in 1 patient, and 5 lesions in a patient. Nodule di-ameters ranged from 2 mm-10 mm (mean: 5 mm). hTe distance of lung lesions from the nearest pleural surfaces ranged within 5 mm-24 mm (mean: 12.5 mm). All resections of lesions guided by the inserted hook wires were successfully performed by VATS (100% success rate). hTe mean procedure time for the CT-guided hook wire localization was 8.4 min (range: 4 min-18 min). hTe mean procedure time for VATS was 32 min (range: 14 min-98 min). hTe median hospital time was 8 d (range: 5 d-14 d). Results of pathological examination revealed 28 primary lung cancers, 9 atypical adenomatous hyperplasia, and 4 nonspe-ciifc chronic inlfammations. No major complication related to the intraoperative hook wire localization and VATS was noted. Conclusion Intraoperative CT-guided hook wire

  9. Fulleropyrrolidine end-capped molecular wires for molecular electronics--synthesis, spectroscopic, electrochemical, and theoretical characterization

    DEFF Research Database (Denmark)

    Sørensen, Jakob Kryger; Fock, Jeppe; Pedersen, Anders Holmen;

    2011-01-01

    -withdrawing ester group present. The effect of extending the p-system of the central wire from 1,4-phenylenediamine to 2,7-fluorenediamine was investigated by absorption, fluorescence, and electrochemical methods. The central wire and the C(60) end-groups were found not to electronically communicate in the ground...

  10. In-Source Laser Spectroscopy with the Laser Ion Source and Trap: First Direct Study of the Ground-State Properties of ^{217,219}Po

    Directory of Open Access Journals (Sweden)

    D. A. Fink

    2015-02-01

    Full Text Available A Laser Ion Source and Trap (LIST for a thick-target, isotope-separation on-line facility has been implemented at CERN ISOLDE for the production of pure, laser-ionized, radioactive ion beams. It offers two modes of operation, either as an ion guide, which performs similarly to the standard ISOLDE resonance ionization laser ion source (RILIS, or as a more selective ion source, where surface-ionized ions from the hot ion-source cavity are repelled by an electrode, while laser ionization is done within a radio-frequency quadrupole ion guide. The first physics application of the LIST enables the suppression of francium contamination in ion beams of neutron-rich polonium isotopes at ISOLDE by more than 1000 with a reduction in laser-ionization efficiency of only 20. Resonance ionization spectroscopy is performed directly inside the LIST device, allowing the study of the hyperfine structure and isotope shift of ^{217}Po for the first time. Nuclear decay spectroscopy of ^{219}Po is performed for the first time, revealing its half-life, α-to-β-decay branching ratio, and α-particle energy. This experiment demonstrates the applicability of the LIST at radioactive ion-beam facilities for the production and study of pure beams of exotic isotopes.

  11. Experimental investigation of radiation charactristics of Ti wire X-pinch X-ray source on Yang accelerator%“阳”加速器钛丝X箍缩光源辐射特性实验研究

    Institute of Scientific and Technical Information of China (English)

    周少彤; 李军; 黄显宾; 蔡红春; 张思群; 李晶; 段书超; 周荣国

    2012-01-01

    The X-ray radiation properties of titanium wire X-pinch are investigated on the Yang accelerator at 500-800 kA peak current with a rise time of about 80 ns. The radiation power, spectrum and source size of the X-pinch X-ray source are measured and analyzed using X-ray diodes, a transmission grating spectrometer, a crystal spectrometer and a slit camera. The hot dense spot smaller than 15 ~tm emits 1 J of X-ray with an FWHM of 200 ps and a peak power of 1.5 GW distributed in the range of 1--4 keV. A method to efficiently generate a single X-ray pulse during the X-pinch implosion is demonstrated. The X-pinch presented here is useful for imaging the early stage interior structure of Z pinch as a backlight source.%为了利用x箍缩产生的点光源作为背光光源对丝阵z箍缩内爆早期的负载内部结构进行背光照相,在“阳”加速器(电流峰值为500--800kA,上升时间约80ns)上开展了钛丝(丝交叉角度为60。)x箍缩光源辐射特性的初步实验研究.通过x射线二极管探测器、透射光栅谱仪、晶体谱仪和狭缝相机等诊断设备获取了箍缩点光源的辐射功率达到1.5GW左右,辐射能量约为1J,光子能量为keV量级的辐射能谱范围主要集中在1—4keV能段,点光源尺寸小于15um,其时间尺度(辐射脉冲半高宽)达到了200ps.对光源特征信息进行了初步分析,同时掌握了有效获取钛丝x箍缩单脉冲点光源的方法.

  12. 7 CFR 1755.406 - Shield or armor ground resistance measurements.

    Science.gov (United States)

    2010-01-01

    ... or armor ground resistance measurements shall be made on completed lengths of copper cable and wire... miles (km) of the cable or wire under test. (4)(i) The objective shield or armor ground resistance may... armor to ground resistance due to temperature. The variations can, however, be substantial for...

  13. Design of a Free and Open Source Data Processing, Archiving, and Distribution Subsystem for the Ground Receiving Station of the Philippine Scientific Earth Observation Micro-Satellite

    Science.gov (United States)

    Aranas, R. K. D.; Jiao, B. J. D.; Magallon, B. J. P.; Ramos, M. K. F.; Amado, J. A.; Tamondong, A. M.; Tupas, M. E. A.

    2016-06-01

    The Philippines's PHL-Microsat program aims to launch its first earth observation satellite, DIWATA, on the first quarter of 2016. DIWATA's payload consists of a high-precision telescope (HPT), spaceborne multispectral imager (SMI) with liquid crystal tunable filter (LCTF), and a wide field camera (WFC). Once launched, it will provide information about the Philippines, both for disaster and environmental applications. Depending on the need, different remote sensing products will be generated from the microsatellite sensors. This necessitates data processing capability on the ground control segment. Rather than rely on commercial turnkey solutions, the PHL-Microsat team, specifically Project 3:DPAD, opted to design its own ground receiving station data subsystems. This paper describes the design of the data subsystems of the ground receiving station (GRS) for DIWATA. The data subsystems include: data processing subsystem for automatic calibration and georeferencing of raw images as well as the generation of higher level processed data products; data archiving subsystem for storage and backups of both raw and processed data products; and data distribution subsystem for providing a web-based interface and product download facility for the user community. The design covers the conceptual design of the abovementioned subsystems, the free and open source software (FOSS) packages used to implement them, and the challenges encountered in adapting the existing FOSS packages to DIWATA GRS requirements.

  14. DESIGN OF A FREE AND OPEN SOURCE DATA PROCESSING, ARCHIVING, AND DISTRIBUTION SUBSYSTEM FOR THE GROUND RECEIVING STATION OF THE PHILIPPINE SCIENTIFIC EARTH OBSERVATION MICRO-SATELLITE

    Directory of Open Access Journals (Sweden)

    R. K. D. Aranas

    2016-06-01

    Full Text Available The Philippines’s PHL-Microsat program aims to launch its first earth observation satellite, DIWATA, on the first quarter of 2016. DIWATA’s payload consists of a high-precision telescope (HPT, spaceborne multispectral imager (SMI with liquid crystal tunable filter (LCTF, and a wide field camera (WFC. Once launched, it will provide information about the Philippines, both for disaster and environmental applications. Depending on the need, different remote sensing products will be generated from the microsatellite sensors. This necessitates data processing capability on the ground control segment. Rather than rely on commercial turnkey solutions, the PHL-Microsat team, specifically Project 3:DPAD, opted to design its own ground receiving station data subsystems. This paper describes the design of the data subsystems of the ground receiving station (GRS for DIWATA. The data subsystems include: data processing subsystem for automatic calibration and georeferencing of raw images as well as the generation of higher level processed data products; data archiving subsystem for storage and backups of both raw and processed data products; and data distribution subsystem for providing a web-based interface and product download facility for the user community. The design covers the conceptual design of the abovementioned subsystems, the free and open source software (FOSS packages used to implement them, and the challenges encountered in adapting the existing FOSS packages to DIWATA GRS requirements.

  15. Historical trends in occurrence and atmospheric inputs of halogenated volatile organic compounds in untreated ground water used as a source of drinking water

    Science.gov (United States)

    Shapiro, S.D.; Busenberg, E.; Focazio, M.J.; Plummer, L.N.

    2004-01-01

    Analyses of samples of untreated ground water from 413 community-, non-community- (such as restaurants), and domestic-supply wells throughout the US were used to determine the frequency of detection of halogenated volatile organic compounds (VOCs) in drinking-water sources. The VOC data were compiled from archived chromatograms of samples analyzed originally for chlorofluorocarbons (CFCs) by purge-and-trap gas chromatography with an electron-capture detector (GC-ECD). Concentrations of the VOCs could not be ascertained because standards were not routinely analyzed for VOCs other than trichloromonofluoromethane (CFC-11), dichlorodifluoromethane (CFC-12) and 1,1,2-trichloro-1,2,2-trifluoroethane (CFC-113). Nevertheless, the peak areas associated with the elution times of other VOCs on the chromatograms can be classified qualitatively to assess concentrations at a detection limit on the order of parts per quadrillion. Three or more VOCs were detected in 100% (percent) of the chromatograms, and 77.2% of the samples contained 10 or more VOCs. The maximum number of VOCs detected in any sample was 24. Modeled ground-water residence times, determined from concentrations of CFC-12, were used to assess historical trends in the cumulative occurrence of all VOCs detected in this analysis, as well as the occurrence of individual VOCs, such as CFC-11, carbon tetrachloride (CCl4), chloroform and tetrachloroethene (PCE). The detection frequency for all of the VOCs detected has remained relatively constant from approximately 1940 to 2000; however, the magnitude of the peak areas on the chromatograms for the VOCs in the water samples has increased from 1940 to 2000. For CFC-11, CCl4, chloroform and PCE, small peaks decrease from 1940 to 2000, and large peaks increase from 1940 to 2000. The increase in peak areas on the chromatograms from analyses of more recently recharged water is consistent with reported increases in atmospheric concentrations of the VOCs. Approximately 44% and 6

  16. Geochemical and isotopic composition of ground water with emphasis on sources of sulfate in the upper Floridan Aquifer in parts of Marion, Sumter, and Citrus counties, Florida

    Science.gov (United States)

    Sacks, Laura A.

    1996-01-01

    In inland areas of northwest central Florida, sulfate concentrations in the Upper Floridan aquifer are extremely variable and sometimes exceed drinking water standards (250 milligrams per liter). This is unusual because the aquifer is unconfined and near the surface, allowing for active recharge. The sources of sulfate and geochemical processes controlling ground-water composition were evaluated in this area. Water was sampled from thirty-three wells in parts of Marion, Sumter, and Citrus Counties, within the Southwest Florida Water Management District; these included at least a shallow and a deep well at fifteen separate locations. Ground water was analyzed for major ions, selected trace constituents, dissolved organic carbon, and stable isotopes (sulfur-34 of sulfate and sulfide, carbon-13 of inorganic carbon, deuterium, and oxygen-18). Sulfate concentrations ranged from less than 0.2 to 1,400 milligrams per liter, with higher sulfate concentrations usually in water from deeper wells. The samples can be categorized into a low sulfate group (less than 30 milligrams per liter) and a high sulfate group (greater than 30 milligrams per liter). For the high sulfate water, concentrations of calcium and magnesium increased concurrently with sulfate. Chemical and isotopic data and mass-balance modeling indicate that the composition of high sulfate waters is controlled by dedolomitization reactions (dolomite dissolution and calcite precipitation, driven by dissolution of gypsum). Gypsum occurs deeper in the aquifer than open intervals of sampled wells. Upward flow has been documented in deeper parts of the aquifer in the study area, which may be driven by localized discharge areas or rapid flow in shallow parts of the aquifer. Mixing between shallow ground water and sulfate-rich water that dissolved gypsum at the base of the aquifer is probably responsible for the range of concentrations observed in the study area. Other solutes that increased with sulfate apparently

  17. Wired to freedom

    DEFF Research Database (Denmark)

    Jepsen, Kim Sune Karrasch; Bertilsson, Margareta

    2017-01-01

    of cochlear implantations among Danish users in order to shed more light on their social and political implications. We situate cochlear implantation in a framework of new life science advances, politics, and user experiences. Analytically, we draw upon the notion of social imaginary and explore the social...... dimension of life science through a notion of public politics adopted from the political theory of John Dewey. We show how cochlear implantation engages different social imaginaries on the collective and individual levels and we suggest that users share an imaginary of being “wired to freedom” that involves...... new access to social life, continuous communicative challenges, common practices, and experiences. In looking at their lives as “wired to freedom,” we hope to promote a wider spectrum of civic participation in the benefit of future life science developments within and beyond the field of Cochlear...

  18. From Wires to Cosmology

    CERN Document Server

    Amin, Mustafa A

    2015-01-01

    We provide a statistical framework for characterizing stochastic particle production in the early universe via a precise correspondence to current conduction in wires with impurities. Our approach is particularly useful when the microphysics is uncertain and the dynamics are complex, but only coarse-grained information is of interest. We study scenarios with multiple interacting fields and derive the evolution of the particle occupation numbers from a Fokker-Planck equation. At late times, the typical occupation numbers grow exponentially which is the analog of Anderson localization for disordered wires. Some statistical features of the occupation numbers show hints of universality in the limit of a large number of interactions and/or a large number of fields. For test cases, excellent agreement is found between our analytic results and numerical simulations.

  19. Survey of Design Points for Low Wire Count PRS Loads

    Science.gov (United States)

    Terry, Robert E.; Apruzese, John P.

    2003-10-01

    Plasma radiation source loads of a few larger diameter wires offer a relatively unexplored path to energetic implosions via the creation of a focused axial stagnation of dense wire cores amidst the assembled precursor plasma. Initial studies^a of low wire count loads show promising results with respect to initial inductance and available stagnation energy. Here we examine the trade space of stagnation energy, machine current, implosion time, and delivered mass for several drivers in common use. a. R.E.Terry, J.P.Apruzese, 14th IEEE Pulse Power Conference Proc., June, 2003.

  20. Finding the magnetic center of sextupole using vibrating wire technique

    CERN Document Server

    Wu, Lei; Li, Chun-hua; Qu, Hua-min

    2016-01-01

    In order to obtain stable and high-quality synchrotron radiation photon, the magnets in the storage ring of High Energy Photon Source(HEPS) need to have a stable support and precise positioning. The vibrating wire technique can be used to pre-align the quadrupoles and sextupoles on one girder with high precision to meet the extremely low emittance requirement of HEPS. This thesis introduces the measurement of magnetic center of sextupole using vibrating wire. According to the measurement results, the magnetic field distribution is consistent with theoretical expectation. And vibrating wire has achieved the purpose of measuring the magnetic center and has reached a certain precision.

  1. Twisting wire scanner

    CERN Document Server

    Gharibyan, V; Krouptchenkov, I; Nölle, D; Tiessen, H; Werner, M; Wittenburg, K

    2012-01-01

    A new type of 'two-in-one' wire scanner is proposed. Recent advances in linear motors' technology make it possible to combine translational and rotational movements. This will allow to scan the beam in two perpendicular directions using a single driving motor and a special fork attached to it. Vertical or horizontal mounting will help to escape problems associated with the 45 deg scanners. Test results of the translational part with linear motors is presented.

  2. Magnetoconductance of quantum wires

    Science.gov (United States)

    Ferreira, Gerson J.; Sammarco, Filipe; Egues, Carlos

    2010-03-01

    At low temperatures the conductance of a quantum wires exhibit characteristic plate-aus due to the quantization of the transverse modes [1]. In the presence of high in-plane magnetic fields these spin-split transverse modes cross. Recently, these crossings were observed experimentally [2] via measurements of the differential conductance as a function of the gate voltage and the in-plane magnetic-field. These show structures described as either anti-crossings or magnetic phase transitions. Motivated by our previous works on magnetotransport in 2DEGs via the Spin Density Functional Theory (SDFT) [3], here we propose a similar model to investigate the magnetoconductance of quantum wires. We use (i) the SDFT via the Kohn-Sham self-consistent scheme within the local spin density approximation to obtain the electronic structure and (ii) the Landauer-Buettiker formalism to calculate the conductance of a quantum wire. Our results show qualitative agreement with the data of Ref. [2]. [1] B. J. van Wees et al., Phys. Rev. Lett. 60, 848 (1988). [2] A. C. Graham et al., Phys. Rev. Lett. 100, 226804 (2008). [3] H. J. P. Freire, and J. C. Egues, Phys. Rev. Lett. 99, 026801 (2007); G. J. Ferreira, and J. Carlos Egues, J. Supercond. Nov. Mag., in press; G. J. Ferreira, H. J. P. Freire, J. Carlos Egues, submitted.

  3. Investigating the Dominant Source for the Generation of Gravity Waves during Indian Summer Monsoon Using Ground-based Measurements

    Institute of Scientific and Technical Information of China (English)

    Debashis NATH; CHEN Wen

    2013-01-01

    Over the tropics,convection,wind shear (i.e.,vertical and horizontal shear of wind and/or geostrophic adjustment comprising spontaneous imbalance in jet streams) and topography are the major sources for the generation of gravity waves.During the summer monsoon season (June-August) over the Indian subcontinent,convection and wind shear coexist.To determine the dominant source of gravity waves during monsoon season,an experiment was conducted using mesosphere-stratosphere-troposphere (MST) radar situated at Gadanki (13.5°N,79.2°E),a tropical observatory in the southern part of the Indian subcontinent.MST radar was operated continuously for 72 h to capture high-frequency gravity waves.During this time,a radiosonde was released every 6 h in addition to the regular launch (once daily to study low-frequency gravity waves) throughout the season.These two data sets were utilized effectively to characterize the jet stream and the associated gravity waves.Data available from collocated instruments along with satellite-based brightness temperature (TBB) data were utilized to characterize the convection in and around Gadanki,Despite the presence of two major sources of gravity wave generation (i.e.,convection and wind shear) during the monsoon season,wind shear (both vertical shear and geostrophic adjustment) contributed the most to the generation of gravity waves on various scales.

  4. Dual wire welding torch and method

    Science.gov (United States)

    Diez, Fernando Martinez; Stump, Kevin S.; Ludewig, Howard W.; Kilty, Alan L.; Robinson, Matthew M.; Egland, Keith M.

    2009-04-28

    A welding torch includes a nozzle with a first welding wire guide configured to orient a first welding wire in a first welding wire orientation, and a second welding wire guide configured to orient a second welding wire in a second welding wire orientation that is non-coplanar and divergent with respect to the first welding wire orientation. A method of welding includes moving a welding torch with respect to a workpiece joint to be welded. During moving the welding torch, a first welding wire is fed through a first welding wire guide defining a first welding wire orientation and a second welding wire is fed through a second welding wire guide defining a second welding wire orientation that is divergent and non-coplanar with respect to the first welding wire orientation.

  5. Simulation of a wire-cylinder-plate positive corona discharge in nitrogen gas at atmospheric pressure

    Energy Technology Data Exchange (ETDEWEB)

    Martins, Alexandre A. [Institute for Plasmas and Nuclear Fusion and Instituto Superior Tecnico, Av. Rovisco Pais, 1049-001 Lisboa (Portugal)

    2012-06-15

    In this work, we are going to perform a simulation of a wire-cylinder-plate positive corona discharge in nitrogen gas, and compare our results with already published experimental results in air for the same structure. We have chosen to simulate this innovative geometry because it has been established experimentally that it can generate a thrust per unit electrode length transmitted to the gas of up to 0.35 N/m and is also able to induce an ion wind top velocity in the range of 8-9 m/s in air. In our model, the used ion source is a small diameter wire, which generates a positive corona discharge in nitrogen gas directed to the ground electrode, after which the generated positive ions are further accelerated in the acceleration channel between the ground and cathode. By applying the fluid dynamic and electrostatic theories, all hydrodynamic and electrostatic forces that act on the considered geometries will be computed in an attempt to theoretically confirm the generated ion wind profile and also the thrust per unit electrode length. These results are important to establish the validity of this simulation tool for the future study and development of this effect for practical purposes.

  6. Simulation of a wire-cylinder-plate positive corona discharge in nitrogen gas at atmospheric pressure

    CERN Document Server

    Martins, Alexandre A

    2012-01-01

    In this work we are going to perform a simulation of a wire-cylinder-plate positive corona discharge in nitrogen gas, and compare our results with already published experimental results in air for the same structure. We have chosen to simulate this innovative geometry because it has been established experimentally that it can generate a thrust per unit electrode length transmitted to the gas of up to 0.35 N/m and is also able to induce an ion wind top velocity in the range of 8-9 m/s in air. In our model, the used ion source is a small diameter wire, which generates a positive corona discharge in nitrogen gas directed to the ground electrode, after which the generated positive ions are further accelerated in the acceleration channel between the ground and cathode. By applying the fluid dynamic and electrostatic theories all hydrodynamic and electrostatic forces that act on the considered geometries will be computed in an attempt to theoretically confirm the generated ion wind profile and also the thrust per u...

  7. A Comparative Parametric Analysis of the Ground Fault Current Distribution on Overhead Transmission Lines

    OpenAIRE

    VINTAN, M.

    2016-01-01

    The ground fault current distribution in an effectively grounded power network is affected by various factors, such as: tower footing impedances, spans lengths, configuration and parameters of overhead ground wires and power conductors, soil resistivity etc. In this paper, we comparatively analyze, using different models, the ground fault current distribution in a single circuit transmission line with one ground wire. A parametric comparative analysis was done in order to stud...

  8. Metering Wheel-Wire Track Wire Boom Deployment Mechanism

    Science.gov (United States)

    Granoff, Mark S.

    2014-01-01

    The NASA MMS Spin Plane Double Probe (SDP) Deployer utilizes a helical path, rotating Metering Wheel and a spring loaded Wire "Holding" Track to pay out a "fixed end" 57 meter x 1.5 mm diameter Wire Boom stored between concentric storage cylinders. Unlike rotating spool type storage devices, the storage cylinders remain stationary, and the boom wire is uncoiled along the length of the cylinder via the rotation of the Metering Wheel. This uncoiling action avoids the need for slip-ring contacts since the ends of the wire can remain stationary. Conventional fixed electrical connectors (Micro-D type) are used to terminate to operational electronics.

  9. sources

    Directory of Open Access Journals (Sweden)

    Shu-Yin Chiang

    2002-01-01

    Full Text Available In this paper, we study the simplified models of the ATM (Asynchronous Transfer Mode multiplexer network with Bernoulli random traffic sources. Based on the model, the performance measures are analyzed by the different output service schemes.

  10. Physical models of spall zone ground motions and the determination of spatial decay rates. Los Alamos Source Region Project

    Energy Technology Data Exchange (ETDEWEB)

    Stump, B.W. [Southern Methodist Univ., Dallas, TX (United States). Dept. of Geological Sciences; Weaver, T.A. [Los Alamos National Lab., NM (United States)

    1992-01-24

    Spall, the tensile failure of near-surface layers, which is observed above contained explosions, has been identified as a possible secondary seismic source contributing to teleseismic and regional signals. The relative importance of this secondary source can be constrained if the motion field in the spall zone is characterized. Spall zone motions from nuclear explosions detonated above the water table at Pahute Mesa are analyzed to develop these models. Acceleration, velocity, displacement, and dwell time measurements are made from gauges placed directly above the explosion, most often at the free surface. Decay of peak motions are strongly affected by the free surface with little change in amplitude out to a free surface range of 100 m/kt{sup l/3} followed by rapid decay beyond. Free surface interactions are assessed with first-order elastic spherical wave calculations that match observed peak velocity decays. These results indicate that the spall zone motions may be strongly affected by the scaled depth of burial of the explosion. Spall zone velocities, displacements and dwell times are compared for consistency with a gravitational model. The data is in agreement with the functional form of theoretical models although observed displacements may be as much as a factor of two to four greater than the model predicts for observed velocities and dwell times. These differences may reflect the continuous nature of the spall process and/or the role of material strength in these phenomena.

  11. Geochemical and isotopic composition of ground water with emphasis on sources of sulfate in the upper Floridan Aquifer and intermediate aquifer system in southwest Florida

    Science.gov (United States)

    Sacks, Laura A.; Tihansky, Ann B.

    1996-01-01

    In southwest Florida, sulfate concentrations in water from the Upper Floridan aquifer and overlying intermediate aquifer system are commonly above 250 milligrams per liter (the drinking water standard), particularly in coastal areas. Possible sources of sulfate include dissolution of gypsum from the deeper part of the Upper Floridan aquifer or the middle confining unit, saltwater in the aquifer, and saline waters from the middle confining unit and Lower Floridan aquifer. The sources of sulfate and geochemical processes controlling ground-water composition were evaluated for the Peace and Myakka River Basins and adjacent coastal areas of southwest Florida. Samples were collected from 63 wells and a saline spring, including wells finished at different depth intervals of the Upper Floridan aquifer and intermediate aquifer system at about 25 locations. Sampling focused along three ground-water flow paths (selected based on a predevelopment potentiometric-surface map). Ground water was analyzed for major ions, selected trace constituents, dissolved organic carbon, and stable isotopes (delta deuterium, oxygen-18, carbon-13 of inorganic carbon, and sulfur-34 of sulfate and sulfide); the ratio of strontium-87 to strontium-86 was analyzed for waters along one of the flow paths. Chemical and isotopic data indicate that dedolomitization reactions (gypsum and dolomite dissolution and calcite precipitation) control the chemical composition of water in the Upper Floridan aquifer in inland areas. This is confirmed by mass-balance modeling between wells in the shallowest interval in the aquifer along the flow paths. However, gypsum occurs deeper in the aquifer than these wells. Upwelling of sulfate-rich water that previously dissolved gypsum in deeper parts of the aquifer is a more likely source of sulfate than gypsum dissolution in shallow parts of the aquifer. This deep ground water moves to shallower zones in the aquifer discharge area. Saltwater from the Upper Floridan aquifer

  12. 500 kV 直流地线融冰方法%Research on the Implementation of DC Ground Wire Ice-melting for 500 kV Niu-Cong Transmission Line

    Institute of Scientific and Technical Information of China (English)

    张锐; 曹双全

    2014-01-01

    介绍输电线路抗冰改造、加装融冰装置及增加覆冰在线监测装置等措施,在线路覆冰初期,启动融冰装置对覆冰导线、地线进行融冰,有效地保护了输电线路的安全。%took many measures such as transmission lines resisting ice, increasing melting ice device and measure of the icing on-line monitoring device, At the beginning of transmission lines iced, starting melting ice device to melt ice for iced conductor lines and grounding lines, taking these measures can protect the safety of the transmission lines effectively.

  13. Research on the Implementation of DC Ground Wire Ice-melting for 500 kV Niu-Cong Transmission Line%500kV直流地线融冰方法

    Institute of Scientific and Technical Information of China (English)

    张锐; 曹双全

    2014-01-01

    介绍输电线路抗冰改造、加装融冰装置及增加覆冰在线监测装置等措施,在线路覆冰初期,启动融冰装置对覆冰导线、地线进行融冰,有效地保护了输电线路的安全。%took many measures such as transmission lines resisting ice, increasing melting ice device and measure of the icing on-line monitoring device, At the beginning of transmission lines iced, starting melting ice device to melt ice for iced conductor lines and grounding lines, taking these measures can protect the safety of the transmission lines effectively.

  14. Corrosion resistance of premodeled wires made of stainless steel used for heart electrotherapy leaders

    Science.gov (United States)

    Przondziono, J.; Walke, W.; Młynarski, R.; Szatka, W.

    2012-05-01

    The purpose of the study is to evaluate resistance to electrochemical corrosion of wire made of X10CrNi18-8 stainless steel designed for use in cardiology treatment. The influence of strain formed in the premodeling process and methods of wire surface preparation to corrosive resistance in artificial plasma solution were analysed. Wire corrosion tests were carried out in the solution of artificial plasma. Resistance to electrochemical corrosion was evaluated on the ground of recorded curves of anodic polarization by means of potentiodynamic method. Potentiodynamic tests carried out enabled to determine how the resistance to pitting corrosion of wire changes, depending on strain formed in the premodeling process as well as on the method of wire surface preparation. For evaluation of phenomena occurring on the surface of tested steel, electrochemical impedance spectroscopy (EIS) was applied. Deterioration of corrosive properties of wire along with the increase in the formed strain hardening was observed.

  15. Observation of abrupt changes associated with air injection into the ground by the time lapse experiment using an ultra-stable seismic source

    Science.gov (United States)

    Kasahara, J.; Ito, S.; Fujiwara, T.; Hasada, Y.; Tsuruga, K.; Ikuta, R.; Fujii, N.; Yamaoka, K.; Nishigami, K.; Ito, K.

    2011-12-01

    To prove the temporal change of seismic waves due to the injection of air into the ground, we carried out a field test near the Nojima Earthquake Fault in Awaji Island using an ultra-stable and conscious seismic source and a seismic array. The newly built seismic ACROSS was installed horizontally as the rotational axis of weight-mass was horizontal. We used 10-35Hz. We injected 80 tons air into the Okasa formation at 100 m depth. We analyzed 31 3-component seismometer records and one 3-component borehole seismometer record at 800m depth. Applying source signature deoconvolution to the filed records, we obtained the transfer function between the source and each receiver. All transfer function associated with injection revealed very large changes of waveforms immediately after the beginning of injection of air at some sites. However the station #7 at 100m from the injection well showed extremely large change at 1 day after the injection. The delay times for appearance of waveform change vary place to place and the differential waveform characteristics for each station are quite different one by one. We explain possible causes of waveform change.

  16. THERMAL CONDUCTIVITY OF METALLIC WIRES

    Institute of Scientific and Technical Information of China (English)

    LU XIANG; GU JI-HUA; CHU JUN-HAO

    2001-01-01

    The effect of radial thickness on the thermal conductivity of a free standing wire is investigated. The thermal conductivity is evaluated using the Boltzmann equation. A simple expression for the reduction in conductivity due to the increase of boundary scattering is presented. A comparison is made between the experimental results of indium wires and the theoretical calculations. It is shown that this decrease of conductivity in wires is smaller than that in film where heat flux is perpendicular to the surface.

  17. A small, lightweight multipollutant sensor system for ground-mobile and aerial emission sampling from open area sources

    Science.gov (United States)

    Zhou, Xiaochi; Aurell, Johanna; Mitchell, William; Tabor, Dennis; Gullett, Brian

    2017-04-01

    Characterizing highly dynamic, transient, and vertically lofted emissions from open area sources poses unique measurement challenges. This study developed and applied a multipollutant sensor and time-integrated sampler system for use on mobile applications such as vehicles, tethered balloons (aerostats) and unmanned aerial vehicles (UAVs) to determine emission factors. The system is particularly applicable to open area sources, such as forest fires, due to its light weight (3.5 kg), compact size (6.75 L), and internal power supply. The sensor system, termed "Kolibri", consists of sensors measuring CO2 and CO, and samplers for particulate matter (PM) and volatile organic compounds (VOCs). The Kolibri is controlled by a microcontroller which can record and transfer data in real time through a radio module. Selection of the sensors was based on laboratory testing for accuracy, response delay and recovery, cross-sensitivity, and precision. The Kolibri was compared against rack-mounted continuous emissions monitoring system (CEMs) and another mobile sampling instrument (the "Flyer") that has been used in over ten open area pollutant sampling events. Our results showed that the time series of CO, CO2, and PM2.5 concentrations measured by the Kolibri agreed well with those from the CEMs and the Flyer, with a laboratory-tested percentage error of 4.9%, 3%, and 5.8%, respectively. The VOC emission factors obtained using the Kolibri were consistent with existing literature values that relate concentration to modified combustion efficiency. The potential effect of rotor downwash on particle sampling was investigated in an indoor laboratory and the preliminary results suggested that its influence is minimal. Field application of the Kolibri sampling open detonation plumes indicated that the CO and CO2 sensors responded dynamically and their concentrations co-varied with emission transients. The Kolibri system can be applied to various challenging open area scenarios such as

  18. Development of a portable and fast wire tension measurement system for MWPC construction

    Science.gov (United States)

    Pan, Jing-Hui; Ma, Chang-Li; Gong, Xue-Yu; Sun, Zhi-Jia; Wang, Yan-Feng; Yin, Chen-Yan; Gong, Lei

    2016-09-01

    In a multi-wire proportional chamber detector (MWPC), the anode and signal wires must maintain suitable tension, which is very important for the detector’s stable and accurate performance. As a result, wire tension control and measurement is essential in MWPC construction. A high pressure 3He MWPC detector is to be used as the thermal neutron detector of the multi-functional reflectometer at China Spallation Neutron Source, and in the construction of the detector, we have developed a wire tension measurement system. This system is accurate, portable and time-saving. With it, the wire tension on an anode wire plane has been tested. The measurement results show that the wire tension control techniques used in detector manufacture are reliable. Supported by National Natural Science Foundation of China (A050506), State Key Laboratory of Particle Detection and Electronics and Key Laboratory of China Academy of Engineering Physics (Y490KF40HD)

  19. Development of a portable, fast and contactless wire tension measurement system for MWPC's construction

    CERN Document Server

    Pan, Jing-Hui; Gong, Xue-Yu; Sun, Zhi-Jia; Wang, Yan-Feng; Yin, Chen-Yan; Gong, Lei

    2016-01-01

    In a multi-wire proportional chamber detector(MWPC), the anode and signal wires must maintain suitable tensions, which is very important for making the detector have steady and perfect performance. As a result, wire tension control and measurement is essential in MWPC's construction. The thermal neutron detector of multi-functional reflectometer at China Spallation Neutron Source is designed using a hight pressure $^{3}$He MWPC detector, and in the construction of the detector, we developed a wire tension measurement system. This system is accurate, portable and time-saving. And, the wires' tension on a anode wire plane has been tested with it, the measurement results shown the wire tension control techniques used in detector manufacture is reliable.

  20. Subminiature Hot-Wire Probes

    Science.gov (United States)

    Westphal, R. V.; Lemos, F. R.; Ligrani, P. M.

    1989-01-01

    Class of improved subminiature hot-wire flow-measuring probes developed. Smaller sizes yield improved resolution in measurements of practical aerodynamic flows. Probe made in one-wire, two-perpendicular-wire, and three-perpendicular-wire version for measurement of one, two, or all three components of flow. Oriented and positioned on micromanipulator stage and viewed under microscope during fabrication. Tested by taking measurements in constant-pressure turbulent boundary layer. New probes give improved measurements of turbulence quantities near surfaces and anisotropies of flows strongly influence relative errors caused by phenomena related to spatial resolution.

  1. Plasma Formation Around Single Wires

    Science.gov (United States)

    Duselis, Peter U.; Kusse, Bruce R.

    2002-12-01

    At Cornell's Laboratory of Plasma Studies, single wires of various metals were exploded using a ˜250 ns pulser with a rise time of ˜20 A/ns. It was found that the wires first experience a resistive heating phase that lasts 50-80 ns before a rapid collapse of voltage. From that point on, the voltage across the wire was negligible while the current through the wire continued to increase. We attribute this voltage collapse to the formation of plasma about the wire. Further confirmation of this explanation will be presented along with new experimental data describing preliminary spectroscopy results, the expansion rate of the plasma, and current flow along the wire as a function of radius. The resistance of the wire-electrode connection will be shown to significantly affect the energy deposition. Various diagnostics were used to obtain these experiments. Ultraviolet sensitive vacuum photodiodes and a framing camera with an 8 ns shutter were used to detect and measure the width of the visible light emitted by the plasma. A special wire holder was constructed that allowed the transfer of current from the wire to the surrounding plasma to be observed.

  2. Texture development in Galfenol wire

    Science.gov (United States)

    Boesenberg, A. J.; Restorff, J. B.; Wun-Fogle, M.; Sailsbury, H.; Summers, E.

    2013-05-01

    Galfenol (Fe-Ga alloy) wire fabrication provides a low cost alternative to directional solidification methods. This work evaluates the compositional dependence of the wire drawing suitability of Fe-Ga and characterizes the microstructural and magnetic properties of these wires. Wire has been produced with Ga contents between 10 at. % and 17 at. % to allow determination of the ductile to brittle transition (DTBT) in wire manufacture. Published results on chill cast bend specimens indicated that a DTBT occurs at roughly 15 at. % Ga. This DTBT was observed under tensile loading with a corresponding change in fracture behavior from transverse fracture to intergranular fracture. For improved magnetostrictive performance, higher Ga contents are desired, closer to the 17 at. % Ga evaluated in this work. Electron backscattered diffraction B-H loop and resonance measurements as a function of magnetic field (to determine modulus and coupling factor) are presented for as-drawn, furnace, and direct current (DC) annealed wire. Galfenol wire produced via traditional drawing methods is found to have a strong (α) texture parallel to the drawing direction. As-drawn wire was observed to have a lower magnetic permeability and larger hysteresis than DC annealed wire. This is attributed to the presence of a large volume of crystalline defects; such as vacancies and dislocations.

  3. Inactivation of Penicillium digitatum Spores by a High-Density Ground-State Atomic Oxygen-Radical Source Employing an Atmospheric-Pressure Plasma

    Science.gov (United States)

    Iseki, Sachiko; Hashizume, Hiroshi; Jia, Fengdong; Takeda, Keigo; Ishikawa, Kenji; Ohta, Takayuki; Ito, Masafumi; Hori, Masaru

    2011-11-01

    Penicillium digitatum spores were inactivated using an oxygen-radical source that supplies only neutral oxygen radicals. Vacuum ultraviolet absorption spectroscopy was used to measure the ground-state atomic oxygen [O (3Pj)] densities and they were estimated to be in the range of 1014-1015 cm-3. The inactivation rate of P. digitatum spores was correlated with the O (3Pj) density. The result indicates that O (3Pj) is the dominant species in the inactivation. The inactivation rate constant of P. digitatum spores by O (3Pj) was estimated to be on the order of 10-17 cm3 s-1 from the measured O (3Pj) densities and inactivation rates.

  4. Design of Ground Source Heat Pump Monitoring System Based on MCGS%基于MCGS的地源热泵监控系统的设计

    Institute of Scientific and Technical Information of China (English)

    商家伟; 苏华

    2016-01-01

    A monitoring system is developed for a ground source heat pump system in Chengdu. Equipments are controlled by PLC and monitoring data is transported from PLC to PC. The host PC moni-toring system is developed by MCGS whose functions cover controlling, operation status displaying, data logging and displaying and alarming.%针对成都某别墅地源热泵系统,设计了一个监控系统方案。利用PLC控制空调设备、监测并上传现场数据给上位机。利用MCGS开发上位机监控系统。该监控系统包含设备控制、状态显示、参数采集及显示、报警等功能。

  5. 多功能地源热泵机组的节能性分析%Energy-saving Analysis on Multifunction Ground Source Heat Pump Unit

    Institute of Scientific and Technical Information of China (English)

    尹永存; 曾庆新

    2014-01-01

    According to the requirements of cooling, heating and hot-water for villa project in Zhengzhou, the advantages and disadvantages of the two kinds of air-conditioning system are compared, those are household air-conditioning unit plus heat-pump water heater, and multifunction ground source heat pump unit. And its energy-saving is analyzed.%结合郑州某别墅工程对供冷、供暖、热水的需求,对比了两种不同空调系统:户式空调机组+热泵热水器,和多功能地源热泵机组性能的优劣;并进行了节能性分析。

  6. Modeling of Morelia Fault Earthquake (Mw=5.4) source fault parameters using the coseismic ground deformation and groundwater level changes data

    Science.gov (United States)

    Sarychikhina, O.; Glowacka, E.; Mellors, R. J.; Vázquez, R.

    2009-12-01

    On 24 May 2006 at 04:20 (UTC) a moderate-size (Mw=5.4) earthquake struck the Mexicali Valley, Baja California, México, roughly 30 km to the southeast of the city of Mexicali, in the vicinity of the Cerro Prieto Geothermal Field (CPGF). The earthquake occurred on the Morelia fault, one of the east-dipping normal faults in the Mexicali Valley. Locally, this earthquake was strongly felt and caused minor damage. The event created 5 km of surface rupture and down-dip displacements of up to 25-30 cm were measured at some places along this surface rupture. Associated deformation was measured by vertical crackmeter, leveling profile, and Differential Synthetic Aperture Radar Interferometry (D-InSAR). A coseismic step-like groundwater level change was detected at 7 wells. The Mw=5.4 Morelia Fault earthquake had significant scientific interest, first, because of surprisingly strong effects for an earthquake of such size; second, the variability of coseismic effects data from different ground-based and space-based techniques which allows to the better constrain of the source fault parameters. Source parameters for the earthquake were estimated using forward modeling of both surface deformation data and static volume strain change (inferred from coseismic changes in groundwater level). All ground deformation data was corrected by anthropogenic component caused by the geothermal fluid exploitation in the CPGF. Modeling was based on finite rectangular fault embedded in an elastic media. The preferred fault model has a strike, rake, and dip of (48°, -89°, 45°) and has a length of 5.2 km, width of 6.7 km, and 34 cm of uniform slip. The geodetic moment, based on the modeled fault parameters, is 1.18E+17 Nm. The model matches the observed surface deformation, expected groundwater level changes, and teleseismic moment reasonably well and explains in part why the earthquake was so strongly felt in the area.

  7. Corrosion of Wires on Wooden Wire-Bound Packaging Crates

    Science.gov (United States)

    Samuel L. Zelinka; Stan Lebow

    2015-01-01

    Wire-bound packaging crates are used by the US Army to transport materials. Because these crates may be exposed to harsh environments, they are dip-treated with a wood preservative (biocide treatment). For many years, zinc-naphthenate was the most commonly used preservative for these packaging crates and few corrosion problems with the wires were observed. Recently,...

  8. Pre-Shot Simulations of Far-Field Ground Motions for the Source Physics Experiment (SPE) Explosions at the Climax Stock, Nevada National Security Site

    Energy Technology Data Exchange (ETDEWEB)

    Rodgers, A J; Wagoner, J; Petersson, N A; Sjogreen, B

    2010-11-07

    The Source Physics Experiment (SPE) will involve a series of explosions in various geologic and emplacement conditions to validate numerical simulation methods to predict behavior of seismic wave excitation and propagation for nuclear test monitoring. The first SPE's currently underway involve explosions in the Climax Stock (granitic geology) at the Nevada National Security Site (NNSS). Detailed geologic data and published material properties for the major lithologic units of the NNSS and surrounding region were used to build three-dimensional models for seismic wave propagation simulations. The geologic structure near the SPE shot point is quite varied including granitic, carbonate, tuff and alluvium lithologies. We performed preliminary ground motion simulations for a near-source domain covering 8 km x 8 km at the surface centered on the shot point to investigate various source and propagation effects using WPP, LLNL's anelastic seismic wave finite difference code. Simulations indicate that variations in wave propagation properties of the sub-surface will generate strongly path-dependent response once the energy has left the relatively small granitic geology of the near-surface Climax Stock near the SPE shot point. Rough topography to the north and west of SPE shot point causes additional complexity in the signals including energy on the transverse components. Waves propagate much faster through the granitic and carbonate formations and slower through the tuff and alluvium. Synthetic seismograms for a pure explosion source in a 3D geologic structure show large amplitudes on transverse component. For paths to the south sampling the granite, tuff and alluvium lithologies transverse component amplitudes are as high as 50% of that on the vertical and radial components.

  9. Choroidal thickness maps from spectral domain and swept source optical coherence tomography: algorithmic versus ground truth annotation.

    Science.gov (United States)

    Philip, Ana-Maria; Gerendas, Bianca S; Zhang, Li; Faatz, Henrik; Podkowinski, Dominika; Bogunovic, Hrvoje; Abramoff, Michael D; Hagmann, Michael; Leitner, Roland; Simader, Christian; Sonka, Milan; Waldstein, Sebastian M; Schmidt-Erfurth, Ursula

    2016-10-01

    The purpose of the study was to create a standardised protocol for choroidal thickness measurements and to determine whether choroidal thickness measurements made on images obtained by spectral domain optical coherence tomography (SD-OCT) and swept source (SS-) OCT from patients with healthy retina are interchangeable when performed manually or with an automatic algorithm. 36 grid cell measurements for choroidal thickness for each volumetric scan were obtained, which were measured for SD-OCT and SS-OCT with two methods on 18 eyes of healthy volunteers. Manual segmentation by experienced retinal graders from the Vienna Reading Center and automated segmentation on >6300 images of the choroid from both devices were statistically compared. Model-based comparison between SD-OCT/SS-OCT showed a systematic difference in choroidal thickness of 16.26±0.725 μm (pthickness of -0.68±0.513 μm (p=0.1833). The correlation coefficients for SD-OCT and SS-OCT measures within eyes were 0.975 for manual segmentation and 0.955 for automatic segmentation. Choroidal thickness measurements of SD-OCT and SS-OCT indicate that these two devices are interchangeable with a trend of choroidal thickness measurements being slightly thicker on SD-OCT with limited clinical relevance. Use of an automated algorithm to segment choroidal thickness was validated in healthy volunteers. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  10. Soft magnetic wires

    Science.gov (United States)

    Vázquez, M.

    2001-06-01

    An overview of the present state of the art on the preparation techniques, outstanding magnetic properties and applications of soft magnetic micro and nanowires is presented. Rapid solidification techniques (in-rotating-water quenching and drawing methods) to fabricate amorphous microwires with diameter in the range from 100 down to 1 μm are first described. Electrodeposition is also employed to prepare composite microtubes (magnetic coatings) and to fill porous membranes (diameter of the order of 0.1 μm). Magnetic behaviours of interest are related to the different hysteresis loops of samples: square-shaped loops typical of bistable behaviour, and nearly non-hysteretic loop with well-defined transverse anisotropy field. The role played by magnetic dipolar interactions in the magnetic behaviour of arrays of micro and nanowires is described. A particular analysis is done on the giant magnetoimpedance (GMI) effect in the radio and microwave frequency ranges exhibited by ultrasoft microwires. Finally, a few examples of applications are introduced for magnetostrictive and non-magnetostrictive wires, they are: “magnetoelastic pens”, micromotors; DC current-sensors based on GMI, and sharpened amorphous wire tips in spin polarised scanning tunneling microscopy.

  11. Wuhan Ground Source Heat Pump Engineering Economic Evaluation Based on the Life Cycle%基于全寿命周期的地源热泵工程经济性评价

    Institute of Scientific and Technical Information of China (English)

    付红阳; 陈伟; 张国辉

    2012-01-01

    通过分析我国地源热泵工程的发展现状及国家和武汉地区政策标准,实地调研武汉地区8个地源热泵工程项目相关经济数据,构建武汉地区地源热泵工程经济性评价体系,通过费用构成分析、能耗分析、运行费用分析和环境评价分析对地源热泵工程进行全寿命周期经济性评价,从而为武汉地区乃至全国推广地源热泵工程提供相关依据和建议。%By analyzing development situation of ground source heat pump engineering and policy standards of China and Wuhan province,the paper investigates related economic data of Wuhan eight ground source heat pump engineering,establishes the economic evaluation system of Wuhan ground source heat pump engineering,and do economic evaluates to ground source heat pump engineering of Wuhan from the analysis of expense components,the energy consumption,the operation cost and the environment evaluation,in order to provide relevant basis and suggestions to promote the promote ground source heat pump engineering of Wuhan to the whole nation.

  12. An early attempt at an integrated home energy system including solar thermal, ground source heat pump, radiant floor heating, reflective and dynamic insulation and ground-tempered makeup air

    Energy Technology Data Exchange (ETDEWEB)

    White, T.

    2005-07-01

    This paper described an attempt to design and build a comfortable and energy efficient home that integrates solar thermal panels with active and passive features. The exterior walls of the 1700 square foot house were interlocking concrete blocks with radiant floor heating pipes fastened to the outside, which was later covered with rigid insulation and stucco. The active heating system included 4 solar panels and a ground source heat pump with supply lines buried horizontally 5 feet below the surface of the back yard on the south side of the building. The solar panels were used for different purposes in different seasons. The system was monitored for the first winter only. For 4 hours a day in January, 10 per cent more solar energy was measured on the vertical collectors than is available from direct solar insolation at summer solstice. With an outside temperature of -33 degrees C, the solar collectors were capable of maintaining an almost constant core wall temperature of 12 degrees C. The total electricity bill for this all-electric house averaged $60 month during for an entire year, with a single occupant. Despite these results, funding to optimize the control system was not granted. The house was sold at a loss and the heat pump was eventually replaced by a natural gas boiler, which reduced the energy efficiency of the house, but which satisfied the bank who wanted a conventional heating system before approving a mortgage. 2 figs.

  13. Coding Issues in Grounded Theory

    Science.gov (United States)

    Moghaddam, Alireza

    2006-01-01

    This paper discusses grounded theory as one of the qualitative research designs. It describes how grounded theory generates from data. Three phases of grounded theory--open coding, axial coding, and selective coding--are discussed, along with some of the issues which are the source of debate among grounded theorists, especially between its…

  14. Coding Issues in Grounded Theory

    Science.gov (United States)

    Moghaddam, Alireza

    2006-01-01

    This paper discusses grounded theory as one of the qualitative research designs. It describes how grounded theory generates from data. Three phases of grounded theory--open coding, axial coding, and selective coding--are discussed, along with some of the issues which are the source of debate among grounded theorists, especially between its…

  15. Pre-shot simulations of far-field ground motion for the Source Physics Experiment (SPE) Explosions at the Climax Stock, Nevada National Security Site: SPE2

    Energy Technology Data Exchange (ETDEWEB)

    Mellors, R J; Rodgers, A; Walter, W; Ford, S; Xu, H; Matzel, E; Myers, S; Petersson, N A; Sjogreen, B; Hauk, T; Wagoner, J

    2011-10-18

    The Source Physics Experiment (SPE) is planning a 1000 kg (TNT equivalent) shot (SPE2) at the Nevada National Security Site (NNSS) in a granite borehole at a depth (canister centroid) of 45 meters. This shot follows an earlier shot of 100 kg in the same borehole at a depth 60 m. Surrounding the shotpoint is an extensive array of seismic sensors arrayed in 5 radial lines extending out 2 km to the north and east and approximately 10-15 to the south and west. Prior to SPE1, simulations using a finite difference code and a 3D numerical model based on the geologic setting were conducted, which predicted higher amplitudes to the south and east in the alluvium of Yucca Flat along with significant energy on the transverse components caused by scattering within the 3D volume along with some contribution by topographic scattering. Observations from the SPE1 shot largely confirmed these predictions although the ratio of transverse energy relative to the vertical and radial components was in general larger than predicted. A new set of simulations has been conducted for the upcoming SPE2 shot. These include improvements to the velocity model based on SPE1 observations as well as new capabilities added to the simulation code. The most significant is the addition of a new source model within the finite difference code by using the predicted ground velocities from a hydrodynamic code (GEODYN) as driving condition on the boundaries of a cube embedded within WPP which provides a more sophisticated source modeling capability linked directly to source site materials (e.g. granite) and type and size of source. Two sets of SPE2 simulations are conducted, one with a GEODYN source and 3D complex media (no topography node spacing of 5 m) and one with a standard isotropic pre-defined time function (3D complex media with topography, node spacing of 5 m). Results were provided as time series at specific points corresponding to sensor locations for both translational (x,y,z) and rotational

  16. BEPC II wire scanner system

    Institute of Scientific and Technical Information of China (English)

    SUI Yan-Feng; WANG Lin; ZHAO Ying; YUE Jun-Hui; LI Xiao-Ping; CAO Jian-She; MA Li

    2010-01-01

    To monitor the beam profile at the end of the linac non-destructively,a wire scanner as a new diagnostic instrument was designed,manufactured and installed in 2007.Since then,several measurements have been carried out using this device.This paper describes the whole system of the wire scanner and the testing results.

  17. Wire and Packing Tape Sandwiches

    Science.gov (United States)

    Rabinowitz, Sandy

    2009-01-01

    In this article, the author describes how students can combine craft wire with clear packing tape to create a two-dimensional design that can be bent and twisted to create a three-dimensional form. Students sandwich wire designs between two layers of tape. (Contains 1 online resource.)

  18. An economic analysis of space solar power and its cost competitiveness as a supplemental source of energy for space and ground markets

    Science.gov (United States)

    Marzwell, N. I.

    2002-01-01

    Economic Growth has been historically associated with nations that first made use of each new energy source. There is no doubt that Solar Power Satellites is high as a potential energy system for the future. A conceptual cost model of the economics value of space solar power (SSP) as a source of complementary power for in-space and ground applications will be discussed. Several financial analysis will be offered based on present and new technological innovations that may compete with or be complementary to present energy market suppliers depending on various institutional arrangements for government and the private sector in a Global Economy. Any of the systems based on fossil fuels such as coal, oil, natural gas, and synthetic fuels share the problem of being finite resources and are subject to ever-increasing cost as they grow ever more scarce with drastic increase in world population. Increasing world population and requirements from emerging underdeveloped countries will also increase overall demand. This paper would compare the future value of SSP with that of other terrestrial renewable energy in distinct geographic markets within the US, in developing countries, Europe, Asia, and Eastern Europe.

  19. Shallow Groundwater Temperatures and the Urban Heat Island Effect: the First U.K City-wide Geothermal Map to Support Development of Ground Source Heating Systems Strategy

    Science.gov (United States)

    Patton, Ashley M.; Farr, Gareth J.; Boon, David P.; James, David R.; Williams, Bernard; Newell, Andrew J.

    2015-04-01

    The first UK city-wide heat map is described based on measurements of groundwater from a shallow superficial aquifer in the coastal city of Cardiff, Wales, UK. The UK Government has a target of reducing greenhouse gas emissions by 80% by 2050 (Climate Change Act 2008) and low carbon technologies are key to achieving this. To support the use of ground source heating we characterised the shallow heat potential of an urban aquifer to produce a baseline dataset which is intended to be used as a tool to inform developers and to underpin planning and regulation. We exploited an existing network of 168 groundwater monitoring boreholes across the city, recording the water temperature in each borehole at 1m depth intervals up to a depth of 20m. We recorded groundwater temperatures during the coldest part of 2014, and repeat profiling of the boreholes in different seasons has added a fourth dimension to our results and allowed us to characterise the maximum depth of seasonal temperature fluctuation. The temperature profiles were used to create a 3D model of heat potential within the aquifer using GOCAD® and the average borehole temperatures were contoured using Surfer® 10 to generate a 2D thermal resource map to support future assessment of urban Ground Source Heat Pumps prospectively. The average groundwater temperature in Cardiff was found to be above the average for England and Wales (11.3°C) with 90% of boreholes in excess of this figure by up to 4°C. The subsurface temperature profiles were also found to be higher than forecast by the predicted geothermal gradient for the area. Potential sources for heat include: conduction from buildings, basements and sub-surface infrastructure; insulation effects of the urban area and of the geology, and convection from leaking sewers. Other factors include recharge inhibition by drains, localised confinement and rock-water interaction in specific geology. It is likely to be a combination of multiple factors which we are hoping

  20. Wire metamaterials: physics and applications.

    Science.gov (United States)

    Simovski, Constantin R; Belov, Pavel A; Atrashchenko, Alexander V; Kivshar, Yuri S

    2012-08-16

    The physics and applications of a broad class of artificial electromagnetic materials composed of lattices of aligned metal rods embedded in a dielectric matrix are reviewed. Such structures are here termed wire metamaterials. They appear in various settings and can operate from microwaves to THz and optical frequencies. An important group of these metamaterials is a wire medium possessing extreme optical anisotropy. The study of wire metamaterials has a long history, however, most of their important and useful properties have been revealed and understood only recently, especially in the THz and optical frequency ranges where the wire media correspond to the lattices of microwires and nanowires, respectively. Another group of wire metamaterials are arrays and lattices of nanorods of noble metals whose unusual properties are driven by plasmonic resonances. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. FIRAS wire grid characterization techniques

    Science.gov (United States)

    Barney, Richard D.; Magner, Thomas J.

    1989-01-01

    Characterization techniques used to verify the quality and spectral performance of the large freestanding wire grid polarizing beamsplitters and input/output polarizers used in the Far Infrared Absolute Spectrophotometer (FIRAS) are presented. The clear aperture of these grids is lined with 20.8 micron diameter gold coated tungsten wire, spaced 33 microns apart. The grid characteristics measured throughout fabrication and space flight qualification are the center to center wire spacing and wire plane flatness. Ideally, the wire grids should produce coherent wavefronts with equal reflectance and transmittance properties. When the spacing is inconsistent, these wavefront intensities are unequal, thus decreasing the efficiency of the grids and reducing the output signal of the FIRAS. The magnitude of the output interferogram is also reduced by incoherence in the interfering wave fronts caused by uneven flatness.

  2. 新型混合地源热泵的土壤热平衡性能模拟%Soil Thermal Balance Performance Simulation of the New Hybrid Ground Source Heat Pump

    Institute of Scientific and Technical Information of China (English)

    刘小银; 彭彪

    2015-01-01

    Ground source heat pump is a new kind of green energy technologies which is advantage in energy conservation and environmental protection. O ne of the severe problems in the process of application is the thermal imbalance of the heat absorption and release to the ground. To solve this problem, this paper presents a new type of hybrid ground source heat pump in which hot w ater systemis combined with air conditioning systemof ground source heat pump. As an example, make a simulation of a new ly designed air conditioning systemof a hotel in Changsha. By comparison of the conventional single ground source heat pump, this new hybrid ground source heat pump has been confirmed to solve the imbalance of the heat absorption and release to the ground, effectively improved the operation efficiency ofairconditioning unitmean while.%地源热泵是一种新型节能环保的绿色能源利用技术,在应用过程中,存在的较大问题之一就是对土壤的吸放热不平衡。针对此问题本文提出了一种新的混合地源热泵形式,将热水系统和地源热泵空调系统进行耦合,对长沙某宾馆进行了系统设计并用T R N SY S进行了长达30年的模拟。通过和传统单一的地源热泵空调系统比较,证实了该系统不仅能有效地解决土壤吸放热不平衡问题,而且有效地提高了机组的运行效率。

  3. HVAC system design of liquid desiccant fresh air unit combined with ground-source heat pump%溶液调湿新风机组与地源热泵相结合的空调设计

    Institute of Scientific and Technical Information of China (English)

    张伟程; 滕汜颖

    2013-01-01

    以上海虹桥产业楼空调系统为例,介绍了溶液调湿新风机组与地源热泵系统的设计,重点介绍了干式末端设备、冷热源主机、地埋管系统、空调水系统及自控系统设计的要点.根据实际运行调试情况,对冷热源水系统、干式风机盘管、高温型地源热泵机组、免费冷热源板式换热器、地源热泵与冷水机组的运行策略及生活热水应用进行了经验总结.%Taking the Shanghai Hongqiao Industrial Building air conditioning system as example, presents the liquid desiccant fresh air unit and ground-source heat pump design. Highlights the design points of the dry terminal device, cold and heat source unit, ground buried pipe system, air conditioning water system and automatic control system. According to the actual operation and commissioning, summarizes experiences of designing the cold and heat sources water system, dry fan-coil unit, high temperature ground-source heat pump, free cold and heat sources plate heat exchanger, water chiller and ground-source heat pump operation strategy and domestic hot water supply.

  4. Software for calculations of surge processes in ground conductors and grounded objects

    Directory of Open Access Journals (Sweden)

    Kuklin D.V.

    2015-03-01

    Full Text Available Software for calculations related to propagation of electromagnetic waves in high-voltage objects (transmission towers and their grounding, substation grounding has been described in the paper. Using the software the oblique thin wire simulation method proposed by Guiffaut et al. (2012 has been verified for conductive medium

  5. CCD Photometry of bright stars using objective wire mesh

    Energy Technology Data Exchange (ETDEWEB)

    Kamiński, Krzysztof; Zgórz, Marika [Astronomical Observatory Institute, Faculty of Physics, A. Mickiewicz University, Słoneczna 36, 60-286 Poznań (Poland); Schwarzenberg-Czerny, Aleksander, E-mail: chrisk@amu.edu.pl [Copernicus Astronomical Centre, ul. Bartycka 18, PL 00-716 Warsaw (Poland)

    2014-06-01

    Obtaining accurate photometry of bright stars from the ground remains problematic due to the danger of overexposing the target and/or the lack of suitable nearby comparison stars. The century-old method of using objective wire mesh to produce multiple stellar images seems promising for the precise CCD photometry of such stars. Furthermore, our tests on β Cep and its comparison star, differing by 5 mag, are very encouraging. Using a CCD camera and a 20 cm telescope with the objective covered by a plastic wire mesh, in poor weather conditions, we obtained differential photometry with a precision of 4.5 mmag per two minute exposure. Our technique is flexible and may be tuned to cover a range as big as 6-8 mag. We discuss the possibility of installing a wire mesh directly in the filter wheel.

  6. Nano-storage wires.

    Science.gov (United States)

    Lee, Dong Jun; Kim, Eunji; Kim, Daesan; Park, Juhun; Hong, Seunghun

    2013-08-27

    We report the development of "nano-storage wires" (NSWs), which can store chemical species and release them at a desired moment via external electrical stimuli. Here, using the electrodeposition process through an anodized aluminum oxide template, we fabricated multisegmented nanowires composed of a polypyrrole segment containing adenosine triphosphate (ATP) molecules, a ferromagnetic nickel segment, and a conductive gold segment. Upon the application of a negative bias voltage, the NSWs released ATP molecules for the control of motor protein activities. Furthermore, NSWs can be printed onto various substrates including flexible or three-dimensional structured substrates by direct writing or magnetic manipulation strategies to build versatile chemical storage devices. Since our strategy provides a means to store and release chemical species in a controlled manner, it should open up various applications such as drug delivery systems and biochips for the controlled release of chemicals.

  7. Performance evaluation of a ground-source heat pump system utilizing a flowing well and estimation of suitable areas for its installation in Aizu Basin, Japan

    Science.gov (United States)

    Shrestha, Gaurav; Uchida, Youhei; Kuronuma, Satoru; Yamaya, Mutsumi; Katsuragi, Masahiko; Kaneko, Shohei; Shibasaki, Naoaki; Yoshioka, Mayumi

    2017-08-01

    Development of a ground-source heat pump (GSHP) system with higher efficiency, and evaluation of its operating performance, is essential to expand the growth of GSHP systems in Japan. A closed-loop GSHP system was constructed utilizing a flowing (artesian) well as a ground heat exchanger (GHE). The system was demonstrated for space-heating and space-cooling of a room (area 126.7 m2) in an office building. The average coefficient of performance was found to be 4.5 for space-heating and 8.1 for space-cooling. The maximum heat exchange rate was 70.8 W/m for space-heating and 57.6 W/m for space-cooling. From these results, it was determined that a GSHP system with a flowing well as a GHE can result in higher performance. With this kind of highly efficient system, energy saving and cost reduction can be expected. In order to assess appropriate locations for the installation of similar kinds of GSHP systems in Aizu Basin, a suitability map showing the distribution of groundwater up-flowing areas was prepared based on the results of a regional-scale three-dimensional analytical model. Groundwater up-flowing areas are considered to be suitable because the flowing well can be constructed at these areas. Performance evaluation of the GSHP system utilizing the flowing well, in conjunction with the prepared suitability map for its installation, can assist in the promotion of GSHP systems in Japan.

  8. Performance evaluation of a ground-source heat pump system utilizing a flowing well and estimation of suitable areas for its installation in Aizu Basin, Japan

    Science.gov (United States)

    Shrestha, Gaurav; Uchida, Youhei; Kuronuma, Satoru; Yamaya, Mutsumi; Katsuragi, Masahiko; Kaneko, Shohei; Shibasaki, Naoaki; Yoshioka, Mayumi

    2017-02-01

    Development of a ground-source heat pump (GSHP) system with higher efficiency, and evaluation of its operating performance, is essential to expand the growth of GSHP systems in Japan. A closed-loop GSHP system was constructed utilizing a flowing (artesian) well as a ground heat exchanger (GHE). The system was demonstrated for space-heating and space-cooling of a room (area 126.7 m2) in an office building. The average coefficient of performance was found to be 4.5 for space-heating and 8.1 for space-cooling. The maximum heat exchange rate was 70.8 W/m for space-heating and 57.6 W/m for space-cooling. From these results, it was determined that a GSHP system with a flowing well as a GHE can result in higher performance. With this kind of highly efficient system, energy saving and cost reduction can be expected. In order to assess appropriate locations for the installation of similar kinds of GSHP systems in Aizu Basin, a suitability map showing the distribution of groundwater up-flowing areas was prepared based on the results of a regional-scale three-dimensional analytical model. Groundwater up-flowing areas are considered to be suitable because the flowing well can be constructed at these areas. Performance evaluation of the GSHP system utilizing the flowing well, in conjunction with the prepared suitability map for its installation, can assist in the promotion of GSHP systems in Japan.

  9. Design of Hybrid Ground Source Heat Pump System in WILO China Ltd. New Production Project%北京某工厂地源热泵系统设计

    Institute of Scientific and Technical Information of China (English)

    张杰

    2015-01-01

    本文以北京某工厂混合式地源热泵空调系统为例,对于混合式地源热泵系统的设计、施工、自控作了较详细的论述,供同行借鉴参考。%Taking Uhybrid ground source heat pump system of a factory in Beijing as a example,design,construction,automatic control and operation about the hybrid ground source heat pump system are demonstrated in details for reference.

  10. Elementary analysis Ground source heat pump system design &Discussion on application prospect%地源热泵系统简介及其应用前景探讨

    Institute of Scientific and Technical Information of China (English)

    傅志宝

    2012-01-01

    介绍地源热泵系统设计形式及设计时应注意的问题,简单介绍在具体工程中设计案例及保障措施,探讨地源热泵系统的应用前景。%Introduction of Ground Source Heat Pump system design and the problems should be attention in the design,Simply introduce a engineering design case in the Specific project guarantee measures,The application prospect of Ground Source Heat Pump system.

  11. Application and Design of Ground Source Heat Pump in Villa Air-conditioning System%地源热泵空调系统在某别墅中的应用

    Institute of Scientific and Technical Information of China (English)

    王红霞; 崔璐

    2012-01-01

    总结了别墅地源热泵系统的形式,以工程为例,详细介绍了地源热泵+风机盘管+地板采暖+全热交换新风系统的设计。%Summarize systems of ground source heat pump used in the villa. With an engineering example, show details of ground source heat pump contains fan coil floor heating and total heat exchange of the fresh air system design.

  12. Application research for ground-source heat pump system applied to large port project%地源热泵空调在大型港口工程中的应用

    Institute of Scientific and Technical Information of China (English)

    张志强

    2009-01-01

    结合工程设计实例,对地源热泵空调在大型港口工程中的应用进行了探讨.对地源热泵和普通中央空调系统的运行费用进行估算和比较.%Combining with practical design example, this paper discusses the application of ground-source heat pump system applied to large port project, and carries out an estimation and comparison of the operating costs between the ground-source heat pump system and common HVAC system.

  13. Operational environments for electrical power wiring on NASA space systems

    Science.gov (United States)

    Stavnes, Mark W.; Hammoud, Ahmad N.; Bercaw, Robert W.

    1994-01-01

    Electrical wiring systems are used extensively on NASA space systems for power management and distribution, control and command, and data transmission. The reliability of these systems when exposed to the harsh environments of space is very critical to mission success and crew safety. Failures have been reported both on the ground and in flight due to arc tracking in the wiring harnesses, made possible by insulation degradation. This report was written as part of a NASA Office of Safety and Mission Assurance (Code Q) program to identify and characterize wiring systems in terms of their potential use in aerospace vehicles. The goal of the program is to provide the information and guidance needed to develop and qualify reliable, safe, lightweight wiring systems, which are resistant to arc tracking and suitable for use in space power applications. This report identifies the environments in which NASA spacecraft will operate, and determines the specific NASA testing requirements. A summary of related test programs is also given in this report. This data will be valuable to spacecraft designers in determining the best wiring constructions for the various NASA applications.

  14. Analysis of ozone and nitric acid in spring and summer Arctic pollution using aircraft, ground-based, satellite observations and MOZART-4 model: source attribution and partitioning

    Directory of Open Access Journals (Sweden)

    C. Wespes

    2012-01-01

    Full Text Available In this paper, we analyze tropospheric O3 together with HNO3 during the POLARCAT (Polar Study using Aircraft, Remote Sensing, Surface Measurements and Models, of Climate, Chemistry, Aerosols, and Transport program, combining observations and model results. Aircraft observations from the NASA ARCTAS (Arctic Research of the Composition of the Troposphere from Aircraft and Satellites and NOAA ARCPAC (Aerosol, Radiation and Cloud Processes affecting Arctic Climate campaigns during spring and summer of 2008 are used together with the Model for Ozone and Related Chemical Tracers, version 4 (MOZART-4 to assist in the interpretation of the observations in terms of the source attribution and transport of O3 and HNO3 into the Arctic (north of 60° N. The MOZART-4 simulations reproduce the aircraft observations generally well (within 15%, but some discrepancies in the model are identified and discussed. The observed correlation of O3 with HNO3 is exploited to evaluate the MOZART-4 model performance for different air mass types (fresh plumes, free troposphere and stratospheric-contaminated air masses.

    Based on model simulations of O3 and HNO3 tagged by source type and region, we find that the anthropogenic pollution from the Northern Hemisphere is the dominant source of O3 and HNO3 in the Arctic at pressures greater than 400 hPa, and that the stratospheric influence is the principal contribution at pressures less 400 hPa. During the summer, intense Russian fire emissions contribute some amount to the tropospheric columns of both gases over the American sector of the Arctic. North American fire emissions (California and Canada also show an important impact on tropospheric ozone in the Arctic boundary layer.

    Additional analysis of tropospheric O3 measurements from ground-based FTIR and from the IASI satellite sounder made

  15. 胸腔镜术前低剂量CT引导下Hook-wire联合亚甲蓝定位肺局灶性磨玻璃样病变%Low-dose CT-guided Localization with a Hook-wire System Combined with Methylene Blue for Focal Ground-glass Opacity before Video-assisted Thoracoscopic Resection

    Institute of Scientific and Technical Information of China (English)

    王玉涛; 王海涛; 赵晓东; 朱勇刚; 周成伟; 卢斌; 周银杰; 葛明亮; 张霞萍; 邓生德

    2012-01-01

    To evaluate low-dose CT ( LDCT)-guided localization by using Hook-wire combined with methylene blue before video-assisted thoracoscopic surgery for pulmonary focal ground-glass opacity (fGGO). Methods From November 2010 to April 2012, we performed video-assisted thoracoscopic wedge resection of the lung on 21 patients with unilateral fGGO (the diameter of fGGO ranged from 5 to 17 mm with a mean of 11.5 mm, and the distance between the parietal pleura and the lesion was 0 to 28 mm). All the patients received LDCT-guided localization with Hook-wire and methylene blue. Results The success rate of LDCT-guided localization was 100%. The procedure was completed in a mean of 21 min (ranged from 15 to 28 min). Intraoperative metal hook shedding occurred in one of the cases, but with video-assisted thoracoscopy and staining with methylene blue to localize the lesion, the resection was completed successfully. In the other case, methylene blue staining failed, but the fGGO was removed by localizing the lesion with Hook-wire. Six patients developed postoperative complications, including asymptomatic pneumothorax (4 cases) , asymptomatic bleeding in the left upper lobe (1 case) , and asymptomatic pneumothorax complicated with right lower lobe hemorrhage (1 case). The mean operation time for video-assisted thoracoscopic surgery was 22 min (15 - 43 min) , and the mean intraoperative blood loss was 31 ml (23 -38 ml). The patients were discharged from hospital in a mean of 7 days after the procedure (5-12 days). Postoperative pathological examination showed carcinoma in situ in 4 cases, microinvasive adenocarcinoma in 3 cases, pulmonary adenocarcinoma in 1, atypical adenomatous hyperplasia in 5, hamartoma in 1 , interstitial pneumonia in 3 , intrapulmonary lymph node hyperplasia in 2, and inflammatory granuloma in 2. Conclusion LDCT-guided localization by using Hook-wire combined with methylene blue is accurate for fGGO with mile complications.%目的 探讨低剂量CT( low-dose CT

  16. Sources

    OpenAIRE

    2015-01-01

    SOURCES MANUSCRITES Archives nationales Rôles de taille 1768/71 Z1G-344/18 Aulnay Z1G-343a/02 Gennevilliers Z1G-340/01 Ivry Z1G-340/05 Orly Z1G-334c/09 Saint-Remy-lès-Chevreuse Z1G-344/18 Sevran Z1G-340/05 Thiais 1779/80 Z1G-391a/18 Aulnay Z1G-380/02 Gennevilliers Z1G-385/01 Ivry Z1G-387b/05 Orly Z1G-388a/09 Saint-Remy-lès-Chevreuse Z1G-391a/18 Sevran Z1G-387b/05 Thiais 1788/89 Z1G-451/18 Aulnay Z1G-452/21 Chennevières Z1G-443b/02 Gennevilliers Z1G-440a/01 Ivry Z1G-452/17 Noiseau Z1G-445b/05 ...

  17. Engineering task plan and status of 241-S-106 Enraf level gauge wire break

    Energy Technology Data Exchange (ETDEWEB)

    Moore, T.L.

    1994-09-01

    This report discusses the findings of a task team which was formed which identified the need for short-term actions to re-establish tank waste level monitoring and to permanently address wire failure. The failed wire was removed and sent to Pacific Northwest Laboratory (PNL) for analysis. It was determined that the cause of the wire failure was due to chloride ion stress corrosion cracking (SCC) of the 316 stainless steel (SS) wire. Radiation induced breakdown of the polyvinyl chloride (PVC) riser liners is suspected to be the source of the chloride ions.

  18. COMPREHENSIVE EVALUATION OF SOLAR ASSISTED GROUND SOURCE HEAT HUMP%太阳能+地源热泵联合循环项目综合评标

    Institute of Scientific and Technical Information of China (English)

    孙洲阳; 陈武

    2013-01-01

    Selection of heating-ventilation-air conditioning (HVAC) cooling and heating source is a multiattribute problem,involving lots of unmeasurable factors.The fuzzy comprehensive evaluation method transfers qualitative indexes into quantitative indexes utilizing fuzzy membership,and solves the problem very well.Evaluation cases include:(1) solar assisted ground source heat hump central air-conditioning; (2) lithium bromide direct-fired absorption chiller; (3) chiller and fuel boiler; (4) chiller and gas boiler; (5) chiller and electrical boiler.The evaluate results show that the case (1) is the best.%提出一种基于模糊数学的综合评价方法——模糊综合评价法.该方法利用模糊隶属度理论把定性指标合理定量化,把定性评价转化为定量评价.评估方案包括:①太阳能+地源热泵联合循环;②溴化锂吸收式直燃机组;③冷水机组+燃油热水锅炉;④冷水机组+燃气热水锅炉;⑤冷水机组+电锅炉.事实证明,利用模糊综合评价方法得出的最终结果与实际评标结果吻合较好,具有良好的实用价值.

  19. Influence of Flaws of Wire Rod Surface, Inclusions and Voids on Wire Breaks in Superfine Wire Drawing

    Science.gov (United States)

    Yoshida, Kazunari; Norasethasopon, Somchai; Shinohara, Tetsuo; Ido, Ryuta

    By means of the finite element analysis (FEA), this study analyzed wire breaks that occurred in the drawing fine wires containing flaws on the wire surface, inclusion and void. The deformation behavior of an inclusion was examined, in which the inclusion's location is assumed to be on the center axis of the wire, and the cause of wire breaks and their prevention method were clarified. It was found that an inclusion diameter/wire diameter ratio of 0.4 or higher increases the likelihood of wire breaks occurring. When the inclusion is not assumed to be in the center axis of the wire, it was also found that necking and wire breaks appear more frequently. FEA showed that a flaw grows with each processing step, when a small circumferential flaw is placed on the wire rod surface, and eventually becomes a surface defect, which is called a check mark in practice.

  20. Review of effects of dielectric coatings on electrical exploding wires and Z pinches

    Science.gov (United States)

    Wu, Jian; Li, Xingwen; Li, Mo; Li, Yang; Qiu, Aici

    2017-10-01

    As the most powerful x-ray source in the laboratories, the wire array Z pinches have been of great relevance to inertial confinement fusions, laboratory astrophysics, and other high-energy density applications. In order to produce x-ray with greater power and higher efficiency, the dynamics of wire array has been investigated extensively, and various methods have been proposed to improve the implosion quality of the wire array. This review focuses on the experimental and theoretical investigations regarding the effects of the dielectric coatings on electrical exploding wires and Z pinches. Since the early 2000, the electrical wire explosion related to the first stage of the wire array Z pinches has been studied extensively, and the results indicated that the dielectric coatings can significantly increase the joule energy deposition into a wire in the initial stage, and even the corona free explosion of tungsten wires can be achieved. Recently, there is an increasing interest in the dynamics of insulated wire array Z pinches. By applying dielectric coatings, the ablation process is suppressed, the x-ray start time is delayed, and the possibility of multi-peak radiation is decreased. This review is organized by the evolution dynamics of wire array Z pinches, and a broad introduction to relevant scientific concepts and various other applications are presented. According to the current research status, the challenges, opportunities and further developments of Z pinch loads using dielectric coatings are proposed to further promote the researches and their applications.

  1. Cavity Mode Related Wire Breaking of the SPS Wire Scanners and Loss Measurements of Wire Materials

    CERN Document Server

    Caspers, Friedhelm; Jensen, E; Koopman, J; Malo, J F; Roncarolo, F

    2003-01-01

    During the SPS high intensity run 2002 with LHC type beam, the breaking of several of the carbon wires in the wire scanners has been observed in their parking position. The observation of large changes in the wire resistivity and thermionic electron emission clearly indicated strong RF heating that was depending on the bunch length. A subsequent analysis in the laboratory, simulating the beam by two probe antennas or by a powered stretched wire, showed two main problems: i) the housing of the wire scanner acts as a cavity with a mode spectrum starting around 350 MHz and high impedance values around 700 MHz; ii) the carbon wire used so far appears to be an excellent RF absorber and thus dissipates a significant part of the beam-induced power. Different wire materials are compared with the classical cavity mode technique for the determination of the complex permittivity in the range of 2-4 GHz. As a resonator a rectangular TE_01n type device is utilized.

  2. Cavity mode related wire breaking of the SPS Wire Scanners and loss measurements of wire materials

    CERN Document Server

    Roncarolo, Federico

    2003-01-01

    During the SPS high intensity run 2002 with LHC type beam, the breaking of several of the carbon wires in the wire scanners has been observed in their parking position. The observation of large changes in the wire resistivity and thermionic electron emission clearly indicated strong RF heating that was depending on the bunch length. A subsequent analysis in the laboratory, simulating the beam by two probe antennas or by a powered stretched wire, showed two main problems: i) the housing of the wire scanner acts as a cavity with a mode spectrum starting around 350MHz and high impedance values around 700 MHz; ii) the carbon wire used so far appears to be an excellent RF absorber and thus dissipates a significant part of the beam-induced power. Different wire materials are compared with the classical cavity mode technique for the determination of the complex permittivity in the range of 2-4 GHz. As a resonator a rectangular TE01n type device is utilized.

  3. Carbonaceous and nitrogenous disinfection by-product formation in the surface and ground water treatment plants using Yellow River as water source

    Institute of Scientific and Technical Information of China (English)

    Yukun Hou; Wenhai Chu; Meng Ma

    2012-01-01

    This work investigated the formation of carbonaceous and nitrogenous disinfection by-preducts (C-DBPs,N-DBPs) upon chlorination of water samples collected from a surface water and a ground water treatment plant (SWTP and GWTP) where the conventional treatment processes,i.e.,coagulation,sedimentation,and filtration were employed.Twenty DBPs,including four trihalomethanes,nine haloacetic acids,seven N-DBPs (dichloroacetamide,trichloroacetamide,dichloroacetonitrile,trich loroacetonitrile,bromochloroacetonitrile,dibromoacetonitrile and trichloronitromethane),and eight volatile chlorinated compounds (dichlomethane (DCM),1,2-dichloroethane,tetrachloroethylene,chlorobenzene,1,2-dichlorobenzene,1,4-dichlorobenzene,1,2,3-trichlorobenzene and 1,2,4-trichlorobenzene) were detected in the two WTPs.The concentrations of these contaminants were all below their corresponding maximum contamination levels (MCLs) regulated by the Standards for Drinking Water Quality of China (GB5749-2006) except for DCM (17.1 μg/L detected vs.20 μg/L MCL).The SWTP had much higher concentrations of DBPs detected in the treated water as well as the DBP formation potentials tested in the filtered water than the GWTP,probably because more precursors (e.g.,dissolved organic carbon,dissolved organic nitrogen) were present in the water source of the SWTP.

  4. Large-eddy simulation of pollutant dispersion from a ground-level area source over urban street canyons with irreversible chemical reactions

    Science.gov (United States)

    Du, T. Z.; Liu, C.-H.; Zhao, Y. B.

    2014-10-01

    In this study, the dispersion of chemically reactive pollutants is calculated by large-eddy simulation (LES) in a neutrally stratified urban canopy layer (UCL) over urban areas. As a pilot attempt, idealized street canyons of unity building-height-to-street-width (aspect) ratio are used. Nitric oxide (NO) is emitted from the ground surface of the first street canyon into the domain doped with ozone (O3). In the absence of ultraviolet radiation, this irreversible chemistry produces nitrogen dioxide (NO2), developing a reactive plume over the rough urban surface. A range of timescales of turbulence and chemistry are utilized to examine the mechanism of turbulent mixing and chemical reactions in the UCL. The Damköhler number (Da) and the reaction rate (r) are analyzed along the vertical direction on the plane normal to the prevailing flow at 10 m after the source. The maximum reaction rate peaks at an elevation where Damköhler number Da is equal or close to unity. Hence, comparable timescales of turbulence and reaction could enhance the chemical reactions in the plume.

  5. "Cut wires grating – single longitudinal wire" planar metastructure to achieve microwave magnetic resonance in a single wire

    OpenAIRE

    G. Kraftmakher; V. Butylkin

    2012-01-01

    Here we present metastructures containing cut-wire grating and a single longitudinal cut-wire orthogonal to grating’s wires. Experimental investigations at microwaves show these structures can provide strong magnetic resonant response of a single nonmagnetic cut-wire in dependence on configuration and sizes in the case when metastructures are oriented along the direction of wave propagation and cut-wires of grating are parallel to the electric field of a plane electromagnetic wave. It is sugg...

  6. The Analysis of Thin Wires Using Higher-Order Elements and Basis Functions

    Energy Technology Data Exchange (ETDEWEB)

    Champagne, N J; Wilton, D R; Rockway, J W

    2006-01-23

    Thin wire analysis was applied to curved wire segments in [1], but a special procedure was needed to evaluate the self and near-self terms. The procedure involved associating the singular behavior with a straight segment tangent to the curved source segment, permitting use of algorithms for straight wires. Recently, a procedure that avoids the singularity extraction for straight wires was presented in [2-4]. In this paper, the approach in [4] is applied to curved (or higher-order) wires using a procedure similar to that used in [1] for singularity extraction. Here, the straight tangent segment is used to determine the quadrature rules to be used on the curved segment. The result is a formulation that allows for a general mixture of higher-order basis functions [5] and higher-order wire segments.

  7. Superconducting wires and fractional flux

    Science.gov (United States)

    Sá de Melo, C. A. R.

    1996-05-01

    The quantization of flux quanta in superconductors is revisited and analyzed in a new geometry. The system analyzed is a superconducting wire. The geometry is such that the superconducting wire winds N times around an insulating cylinder and that the wire has its end connected back to its beginning, thus producing an N-loop short circuited solenoid. The winding number N acts as a topological index that controls flux quantization. In this case, fractional flux quanta can be measured through the center of the insulating cylinder, provided that the cylinder radius is small enough. The Little-Parks experiment for an identical geometry is discussed. The period of oscillation of the transition temperature of the wire is found to vary as 1/N in units of flux Φ relative to the flux quantum Φ0. When a SQUID is made in such a geometry the maximal current through the SQUID varies with period Φ0/N.

  8. Wire ropes tension, endurance, reliability

    CERN Document Server

    Feyrer, Klaus

    2015-01-01

    The main goal of this book is to present the methods used to calculate the most important parameters for ropes, and to explain how they are applied on the basis of numerous sample calculations. The book, based on the most important chapters of the German book DRAHTSEILE, has been updated to reflect the latest developments, with the new edition especially focusing on computational methods for wire ropes. Many new calculations and examples have also been added to facilitate the dimensioning and calculation of mechanical characteristics of wire ropes. This book offers a valuable resource for all those working with wire ropes, including construction engineers, operators and supervisors of machines and installations involving wire ropes.

  9. Wire Jewelry/Black History.

    Science.gov (United States)

    Daniel, Robert A.; Robinson, Charles C.

    1984-01-01

    Described is a project which made the study of Black history more real to fifth graders by having them make wire jewelry, smaller versions of the ornate filigreed ironwork produced by slave blacksmiths. (RM)

  10. Dieless wire drawing with lasers

    Science.gov (United States)

    Liedl, G.; Schuöcker, D.

    2007-06-01

    Thin wires are produced by drawing through nozzle-like tools, so called dies, that suffer from strong wear due to friction. In order to avoid the latter disadvantage the dies can be replaced by a laser beam heating the wire to such extend that the yield strength becomes smaller than the tensile strength and thus the wire is elongated and consequently constricted. To avoid rupture, the wire is cooled down again after the desired reduction of the diameter is reached. A further important advantage of this new process is that only one drawing step with a laser can substitute a large number of mechanical drawing actions, thus making the process much more efficient. Theoretical considerations and experimental investigations prove the feasibility of the latter new laser process and are subject to a description in the actual paper.

  11. 49 CFR 236.74 - Protection of insulated wire; splice in underground wire.

    Science.gov (United States)

    2010-10-01

    ... underground wire. 236.74 Section 236.74 Transportation Other Regulations Relating to Transportation (Continued... wire; splice in underground wire. Insulated wire shall be protected from mechanical injury. The insulation shall not be punctured for test purposes. Splice in underground wire shall have insulation...

  12. 49 CFR 234.241 - Protection of insulated wire; splice in underground wire.

    Science.gov (United States)

    2010-10-01

    ... underground wire. 234.241 Section 234.241 Transportation Other Regulations Relating to Transportation... of insulated wire; splice in underground wire. Insulated wire shall be protected from mechanical injury. The insulation shall not be punctured for test purposes. A splice in underground wire shall have...

  13. Composite conductor containing superconductive wires

    Energy Technology Data Exchange (ETDEWEB)

    Larson, W.L.; Wong, J.

    1974-03-26

    A superconductor cable substitute made by coworking multiple rods of superconductive niobium--titanium or niobium--zirconium alloy with a common copper matrix to extend the copper and rods to form a final elongated product which has superconductive wires distributed in a reduced cross-section copper conductor with a complete metallurgical bond between the normal-conductive copper and the superconductor wires contained therein is described. The superconductor cable can be in the form of a tube.

  14. Method of manufacturing superconductor wire

    Science.gov (United States)

    Motowidlo, Leszek

    2014-09-16

    A method for forming Nb.sub.3Sn superconducting wire is provided. The method employs a powder-in-tube process using a high-tin intermetallic compound, such as MnSn.sub.2, for producing the Nb.sub.3Sn. The use of a high-tin intermetallic compound enables the process to perform hot extrusion without melting the high-tin intermetallic compound. Alternatively, the method may entail drawing the wire without hot extrusion.

  15. Topology Optimized Photonic Wire Splitters

    DEFF Research Database (Denmark)

    Frandsen, Lars Hagedorn; Borel, Peter Ingo; Jensen, Jakob Søndergaard;

    2006-01-01

    Photonic wire splitters have been designed using topology optimization. The splitters have been fabricated in silicon-on-insulator material and display broadband low-loss 3dB splitting in a bandwidth larger than 100 nm.......Photonic wire splitters have been designed using topology optimization. The splitters have been fabricated in silicon-on-insulator material and display broadband low-loss 3dB splitting in a bandwidth larger than 100 nm....

  16. Application of Construction Technology of Ground Source Heat Pump System in Dongying Software Park Project%土壤源热泵系统施工技术在东营软件大厦工程中的应用

    Institute of Scientific and Technical Information of China (English)

    尚秀委; 刘乐

    2011-01-01

    土壤源热泵是一种利用土壤所储藏的太阳能资源作为冷热源,进行能量转换的供暖制冷空调系统,是清洁的可再生能源的一种新技术.笔者结合工程实际情况,详细介绍了土壤源热泵系统的优点、组成及施工工艺,并且重点介绍了室外地埋管换热器的施工工艺,为今后土壤源热泵空调系统施工质量控制提供了宝贵经验.%The ground source heat pump is a heating and ventilating air conditioning system using the solar energy resources stored by earth as cold and heat sources,and also a new technology of the clean renewable energy.In combination with the project practice,the article expounds in detail the advantages,compositions and construction craft of the ground source heat pump(GSHP)system,and the introduction focuses on the construction craft of the outdoor ground heat exchanger,which provides valuable experience for the construction quality control of the future ground source heat pump air-conditioning system.

  17. On the Application of Ground Source Heat Pump System in the Airport Hotel%机场宾馆地源热泵系统方案的应用研究

    Institute of Scientific and Technical Information of China (English)

    嵇竑

    2016-01-01

    The construction of the airport hotel needs to consider air conditioning supply and hot water service throughout the year. From the perspective of energy saving transformation, the construction of ground source heat pump system has huge difference with the conventional system in economic and environmental protection terms. From the basic principle of ground source heat pump system, this paper analyzes the advantages and disadvantages of the application of ground source heat pump system in airport hotel to explore the practical application value and broad prospects of the development of ground source heat pump system.%机场宾馆建设需要考虑全年提供冷暖空调、热水服务等,从节能改造的角度出发,建设地源热泵系统对比常规系统在经济方面和环保方面将产生巨大差异.本文从地源热泵系统的基本原理出发,分析研究地源热泵系统在机场宾馆应用中的优势与劣势,并由此探究地源热泵系统发展的实际应用价值和广阔前景.

  18. System Design and Energy Saving Technology Analysis of Ground-source Heat Pump%土壤源热泵系统设计与节能技术分析

    Institute of Scientific and Technical Information of China (English)

    赵金秀; 周红星

    2009-01-01

    The design scheme and characteristics of the ground-source heat pump system were introduced.In addition,the energy consumption during operation periods was briefly analyzed.%主要介绍了土壤源热泵系统的设计及特点,并初步分析了该系统的运行能耗情况.

  19. 太阳能—地源热泵联合循环技术研究%Study on Technologies of Solar Energy and Ground Source Heat Pump Combined Circulation

    Institute of Scientific and Technical Information of China (English)

    孙洲阳; 陈武

    2011-01-01

    太阳能—地源热泵系统联合循环的研究目前还没有形成完备的理论体系,可供应用的基础数据不足,还不能为工程实际应用提供充足的理论依据.本文就太阳能与地源热泵系统联合运行的必要性和可行性进行探讨,提出了相应的技术方案;总结太阳能—地源热泵空调系统的特性,提出太阳能—地源热泵空调系统有待解决的问题,为太阳能—地源热泵联合循环技术在建筑上应用提供参考和借鉴.%Theory system of solar energy combined with ground-source heat pump has not been mature, thereby lack basic data and theory thereunder for engineering application. Necessarity and feasibility of solar energy combined with ground-source heat pump is discussed, bring forward corresponding technique scheme. Character of solar energy combined with ground-source heat pump system is summarized, and bring forward await settle problems, provide reference for architecture application of solar energy combined with ground-source heat pump.

  20. 地源热泵数据监测系统技术评价与应用分析%Technical evaluation and application analysis of ground-source heat pump data monitoring systems

    Institute of Scientific and Technical Information of China (English)

    王华军; 齐承英; 赵冰; 湛文贤

    2012-01-01

    根据当前地源热泵数据监测系统的实施情况,将其分为地下型、地上型、地下+地上型,并进行了技术评价.结合工程实例,介绍了地上型地源热泵数据监测系统的应用情况.提出了尽快完善地源热泵数据监测系统标准体系的建议.%Based on the implementation practice of ground-source heat pump data monitoring systems, classifies the ground-source heat pump data monitoring systems as underground type, overground type and underground plus overground type, and evaluates each of them. With a project example, presents the application of overground type ground-source heat pump data monitoring systems. Proposes to develop ground-source heat pump data monitoring technology standard system as soon as possible.

  1. 浙江地区地源热泵系统适应性研究和设计方法%Adaptability and Design Method for Ground-source Heat Pump System in Zhejiang Province

    Institute of Scientific and Technical Information of China (English)

    唐峰; 胡吉士

    2014-01-01

    Currently, ground-source heat pump technology is widely applied as a renewable energy technology in Zhejiang. From a practical application point of view, there are still many errors in the appli-cable building types and design of the technology. The adaptability of ground-source heat pump system in different building types is analyzed with years of experience in designing ground-source heat pump system. The design methods are presented. The work would provide method and reference for reasonable applica-tion of ground-source heat pump technology in places with hot summer and cold winter.%目前,地源热泵技术作为一项可再生能源技术在浙江地区大力推进。从实际应用看,该技术在适用的建筑类型和设计方面尚存在诸多误区。结合笔者对地源热泵系统多年的设计经验,研究分析了浙江地区地源热泵系统在不同建筑类型中的适应性,并提出了相应的设计方法,可为夏热冬冷地区合理应用地源热泵技术提供参考。

  2. 1 mil gold bond wire study.

    Energy Technology Data Exchange (ETDEWEB)

    Huff, Johnathon; McLean, Michael B.; Jenkins, Mark W.; Rutherford, Brian Milne

    2013-05-01

    In microcircuit fabrication, the diameter and length of a bond wire have been shown to both affect the current versus fusing time ratio of a bond wire as well as the gap length of the fused wire. This study investigated the impact of current level on the time-to-open and gap length of 1 mil by 60 mil gold bond wires. During the experiments, constant current was provided for a control set of bond wires for 250ms, 410ms and until the wire fused; non-destructively pull-tested wires for 250ms; and notched wires. The key findings were that as the current increases, the gap length increases and 73% of the bond wires will fuse at 1.8A, and 100% of the wires fuse at 1.9A within 60ms. Due to the limited scope of experiments and limited data analyzed, further investigation is encouraged to confirm these observations.

  3. HTS Wire Development Workshop: Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    1994-07-01

    The 1994 High-Temperature Superconducting Wire Development Workshop was held on February 16--17 at the St. Petersburg Hilton and Towers in St. Petersburg, Florida. The meeting was hosted by Florida Power Corporation and sponsored by the US Department of Energy`s Superconductivity Program for Electric Power Systems. The meeting focused on recent high-temperature superconducting wire development activities in the Department of Energy`s Superconductivity Systems program. The meeting opened with a general discussion on the needs and benefits of superconductivity from a utility perspective, the US global competitiveness position, and an outlook on the overall prospects of wire development. The meeting then focused on four important technology areas: Wire characterization: issues and needs; technology for overcoming barriers: weak links and flux pinning; manufacturing issues for long wire lengths; and physical properties of HTS coils. Following in-depth presentations, working groups were formed in each technology area to discuss the most important current research and development issues. The working groups identified research areas that have the potential for greatly enhancing the wire development effort. These areas are discussed in the summary reports from each of the working groups. This document is a compilation of the workshop proceedings including all general session presentations and summary reports from the working groups.

  4. Wire Scanner Motion Control Card

    CERN Document Server

    Forde, S E

    2006-01-01

    Scientists require a certain beam quality produced by the accelerator rings at CERN. The discovery potential of LHC is given by the reachable luminosity at its interaction points. The luminosity is maximized by minimizing the beam size. Therefore an accurate beam size measurement is required for optimizing the luminosity. The wire scanner performs very accurate profile measurements, but as it can not be used at full intensity in the LHC ring, it is used for calibrating other profile monitors. As the current wire scanner system, which is used in the present CERN accelerators, has not been made for the required specification of the LHC, a new design of a wire scanner motion control card is part of the LHC wire scanner project. The main functions of this card are to control the wire scanner motion and to acquire the position of the wire. In case of further upgrades at a later stage, it is required to allow an easy update of the firmware, hence the programmable features of FPGAs will be used for this purpose. The...

  5. Connecting to Thermocouples with Fewer Lead Wires

    Science.gov (United States)

    Goldsby, Jon C.

    2003-01-01

    A simple technique has been devised to reduce the number of lead wires needed to connect an array of thermocouples to the instruments (e.g., voltmeters) used to read their output voltages. Because thermocouple wires are usually made of expensive metal alloys, reducing the number of lead wires can effect a considerable reduction in the cost of such an array. Reducing the number of wires also reduces the number of terminals and the amount of space needed to accommodate the wires.

  6. Designing an Optimal Lightning Protection Scheme for Substations Using Shielding Wires

    Directory of Open Access Journals (Sweden)

    A. Khodadadi

    2017-06-01

    Full Text Available An optimal lightning protection scheme for a substation using shielding wires is investigated in this paper through computer software analysis. An economic approach is utilized by choosing a reasonable trade-off between protection, the number of shielding wires and the heights of them from the ground. This study is initially applied to a simple two-wire system and then extended to a sample substation. The solution for each problem is executed in MATLAB and 3-D realization is shown.

  7. Multipass Narrow Gap of Heavy Gauge Steel with Filler Wire

    Science.gov (United States)

    Markushov, Y.; Evtihiev, N.; Grezev, N.; Murzakov, M.

    This article describes method of heavy gauge welding using laser radiation as beam source of energy. The article contains the results of single-pass laser-arc welding and multipass laser welding with filler wire; highlight benefits and drawbacks of each welding method. The results obtained were compared with the traditional methods of welding of the same thickness.

  8. Airport Ground Staff Scheduling

    DEFF Research Database (Denmark)

    Clausen, Tommy

    travels safely and efficiently through the airport. When an aircraft lands, a significant number of tasks must be performed by different groups of ground crew, such as fueling, baggage handling and cleaning. These tasks must be complete before the aircraft is able to depart, as well as check......-in and security services. These tasks are collectively known as ground handling, and are the major source of activity with airports. The business environments of modern airports are becoming increasingly competitive, as both airports themselves and their ground handling operations are changing to private...... ownership. As airports are in competition to attract airline routes, efficient and reliable ground handling operations are imperative for the viability and continued growth of both airports and airlines. The increasing liberalization of the ground handling market prompts ground handling operators...

  9. Influence of the non-homogeneity of Ir-192 wires in calibration of well chambers

    Science.gov (United States)

    Pérez-Calatayud, J.; Ballester, F.; Granero, D.; Brosed, A.

    2003-12-01

    All international recommendations point out as necessary the calibration or verification of the reference air kerma rate (RAKR) for brachytherapy sources (independent of manufacturer established value) prior to their clinical use. The most common procedure for RAKR measurement in iridium wires is based on the use of well chambers with specific inserts that set the wire in a fixed position; previously, the electrometer plus well chamber with insert (EWI) was calibrated by using a source obtained from an accredited laboratory for which the RKAR was established precisely, called the 'reference' source. The distribution of Ir-192 material in the wire could be not perfectly homogeneous all along its length, and in this case the influence of these inhomogeneities in the calibration process should be studied. This paper focuses on the evaluation of this topic and an analytical and experimental study is presented taking into account the non-homogeneity of Ir-192 material along the wire for both the reference source (of length 14 cm) and a wire of unknown RAKR. This study is based on measurements with a 1 cm iridium wire on a rectilinear insert considering either of the two available reference sources (1 or 14 cm length), and has been experimentally evaluated using two typical well chambers. The main conclusion of the study is that if the non-homogeneity of the wires is lower than 5% the effect of non-homogeneity on RAKR measurements is negligible for rectilinear inserts even for short well chambers.

  10. Influence of the non-homogeneity of Ir-192 wires in calibration of well chambers

    Energy Technology Data Exchange (ETDEWEB)

    Perez-Calatayud, J [Radiation Oncology Department, ' La Fe' University Hospital, Valencia (Spain); Ballester, F [Department of Atomic, Molecular and Nuclear Physics, University of Valencia, and Instituto de FIsica Corpuscular (IFIC), Burjassot (Spain); Granero, D [Department of Atomic, Molecular and Nuclear Physics, University of Valencia, and Instituto de FIsica Corpuscular (IFIC), Burjassot (Spain); Brosed, A [CIEMAT, Ministerio de Ciencia y TecnologIa, Madrid (Spain)

    2003-12-07

    All international recommendations point out as necessary the calibration or verification of the reference air kerma rate (RAKR) for brachytherapy sources (independent of manufacturer established value) prior to their clinical use. The most common procedure for RAKR measurement in iridium wires is based on the use of well chambers with specific inserts that set the wire in a fixed position; previously, the electrometer plus well chamber with insert (EWI) was calibrated by using a source obtained from an accredited laboratory for which the RKAR was established precisely, called the 'reference' source. The distribution of Ir-192 material in the wire could be not perfectly homogeneous all along its length, and in this case the influence of these inhomogeneities in the calibration process should be studied. This paper focuses on the evaluation of this topic and an analytical and experimental study is presented taking into account the non-homogeneity of Ir-192 material along the wire for both the reference source (of length 14 cm) and a wire of unknown RAKR. This study is based on measurements with a 1 cm iridium wire on a rectilinear insert considering either of the two available reference sources (1 or 14 cm length), and has been experimentally evaluated using two typical well chambers. The main conclusion of the study is that if the non-homogeneity of the wires is lower than 5% the effect of non-homogeneity on RAKR measurements is negligible for rectilinear inserts even for short well chambers.

  11. 铁路站房地源热泵系统工程热平衡分析%Analysis on Heat Balance of Ground Source Heat Pump System in Railway Station

    Institute of Scientific and Technical Information of China (English)

    沈德安

    2013-01-01

    Abstract:In regard to an actual railway station,based on its design circumstance of air-condition heating system and its testing report of ground heat transfer characteristics,the ground source heat pump system was adopted as its cold and heat source.Considering the need for heat balance of the ground source heat pump system,this thesis analyzes the two different schemes used in railway station buildings:the one is a ground source heat pump system assisted by boiler,and the other is a coupled system of solar energy with ground source heat pump.And then respectively for both schemes,this thesis calculates the required capacity of ground source heat pump unit and the required design scale of ground heat exchanger.This thesis also discusses how to achieve the cold and heat balance for the two different schemes,and analyzes each characteristics and applicability in actual projects.Finally this thesis points out:it is necessary to use suitable and customized heat balance modes for different projects on the basis of local conditions.%结合具体工程,根据某车站空调采暖系统设计工况及该工程地埋管换热特性测试报告,采用地源热泵系统作为冷热源.考虑地源热泵系统的冷热平衡需要,分析采用地源热泵+锅炉辅助系统及太阳能地源热泵耦合系统两种不同热平衡方案用于铁路站房,计算各自需要的热泵机组容量及室外埋管换热器具体设计规模.详细介绍两种系统的冷热平衡方式,并对各自特点及工程运用进行论述,提出在具体工程中因地制宜,应根据不同情况,采用合适的系统热平衡方式.

  12. Polyurethane spray coating of aluminum wire bonds to prevent corrosion and suppress resonant oscillations

    CERN Document Server

    INSPIRE-00092738; Kurth, Matthew; Boyd, Rusty

    2016-01-01

    Unencapsulated aluminum wedge wire bonds are common in particle physics pixel and strip detectors. Industry-favored bulk encapsulation is eschewed due to the range of operating temperatures and radiation. Wire bond failures are a persistent source of tracking-detector failure. Unencapsulated bonds are vulnerable to condensation-induced corrosion, particularly when halides are present. Oscillations from periodic Lorentz forces are documented as another source of wire bond failure. Spray application of polyurethane coatings, performance of polyurethane-coated wire bonds after climate chamber exposure, and resonant properties of polyurethane-coated wire bonds and their resistance to periodic Lorentz forces are under study for use in a future High Luminosity Large Hadron Collider detector such as the ATLAS Inner Tracker upgrade.

  13. Microbiological and chemical quality of ground water used as a source of public supply in southern Missouri : Phase II, April-July, 1998

    Science.gov (United States)

    Femmer, Suzanne R.

    2000-01-01

    The protection of public health through quality public ground-water systems is the responsibility of the U. S. Environmental Protection Agency and the State of Missouri, through the Missouri Department of Natural Resources, Public Drinking Water Program. Approximately 95 percent of the public-water supplies in Missouri use ground water as their source of drinking water through more than 3,700 public wells. Karst terrain, intensive agricultural operations, extensive numbers of on-site sewage systems, and poor well construction can lead to chemical and microbiological contamination of the contributing aquifers. Sitespecific studies and routine regulatory monitoring have produced information on the overall quality and potability of the State's public-drinking-water supplies, but little is known about the presence of viruses. The U.S. Geological Survey, in cooperation with the Missouri Department of Natural Resources, sampled 109 public-water supplies to characterize the physical, chemical, bacterial, and viral conditions in southern Missouri. During April to July 1998, these wells were sampled for nutrients, total organic carbon, optical brighteners, indicator bacteria, enteric viruses, and ribonucleic acid and somatic coli phages. These constituents indicate possible surface contamination of the sampled aquifer. Selection of the wells to be sampled depended on the age of the well (pre-1970), land use, geohydrology, and well construction. None of the physical or chemical constituents measured or analyzed exceeded Missouri's Drinking Water Standards set by the Public Drinking Water Program of the Missouri Department of Natural Resources. The majority of ammonia plus organic nitrogen, nitrite, and phosphorus concentrations were below the laboratory's minimum reporting levels. There were a greater number of detects above the minimum reporting level with respect to the nitrite plus nitrate, ammonia, orthophosphate, and total organic carbon concentrations. Analyses

  14. Dissecting the Power Sources of Low-Luminosity Emission-Line Galaxy Nuclei via Comparison of HST-STIS and Ground-Based Spectra

    Science.gov (United States)

    Constantin, Anca; Shields, Joseph C.; Ho, Luis C.; Barth, Aaron J.; Filippenko, Alexei V.; Castillo, Christopher A.

    2015-12-01

    Using a sample of ∼100 nearby line-emitting galaxy nuclei, we have built the currently definitive atlas of spectroscopic measurements of Hα and neighboring emission lines at subarcsecond scales. We employ these data in a quantitative comparison of the nebular emission in Hubble Space Telescope (HST) and ground-based apertures, which offer an order-of-magnitude difference in contrast, and provide new statistical constraints on the degree to which transition objects and low-ionization nuclear emission-line regions (LINERs) are powered by an accreting black hole at ≲10 pc. We show that while the small-aperture observations clearly resolve the nebular emission, the aperture dependence in the line ratios is generally weak, and this can be explained by gradients in the density of the line-emitting gas: the higher densities in the more nuclear regions potentially flatten the excitation gradients, suppressing the forbidden emission. The transition objects show a threefold increase in the incidence of broad Hα emission in the high-resolution data, as well as the strongest density gradients, supporting the composite model for these systems as accreting sources surrounded by star-forming activity. The narrow-line LINERs appear to be the weaker counterparts of the Type 1 LINERs, where the low accretion rates cause the disappearance of the broad-line component. The enhanced sensitivity of the HST observations reveals a 30% increase in the incidence of accretion-powered systems at z ≈ 0. A comparison of the strength of the broad-line emission detected at different epochs implies potential broad-line variability on a decade-long timescale, with at least a factor of three in amplitude. Based on observations made with the NASA/ESA Hubble Space Telescope, obtained from the data archive at the Space Telescope Science Institute. STScI is operated by the Association of Universities for Research in Astronomy, Inc., under NASA contract NAS 5-26555.

  15. Radon as a tracer to characterize the interactions between groundwater and surface water around the ground source heat pump system in riverside area

    Science.gov (United States)

    Kim, Jaeyeon; Lee, Seong-Sun; Lee, Kang-Kun

    2016-04-01

    The interaction characteristics between groundwater and surface water was examined by using Radon-222 at Han River Environmental Research Center (HRERC) in Korea where a geothermal resource using indirect open loop ground source heat pump (GSHP) has been developed. For designing a high efficiency performance of the open loop system in shallow aquifer, the riverside area was selected for great advantage of full capacity of well. From this reason groundwater properties of the study site can be easily influenced by influx of surrounding Han River. Therefore, 12 groundwater wells were used for monitoring radon concentration and groundwater level with fluctuation of river stage from May, 2014 to Apr., 2015. The short term monitoring data showed that the radon concentration was changed in accordance with flow meter data which was reflected well by the river stage fluctuation. The spatial distribution of radon concentration from long term monitoring data was also found to be affected by water level fluctuation by nearby dam activity and seasonal effect such as heavy rainfall and groundwater pumping. The estimated residence time indicates that river flows to the study site change its direction according to the combined effect of river stage and groundwater hydrology. In the linear regression of the values, flow velocities were yielded around 0.04 to 0.25 m/day which were similar to flow meter data. These results reveal that Radon-222 can be used as an appropriate environmental tracer in examining the characteristics of interaction in consideration of fluctuating river flow on operation of GSHP in the riverside area. ACKNOWLEDGEMENT This work was supported by the research project of "Advanced Technology for Groundwater Development and Application in Riversides (Geowater+) in "Water Resources Management Program (code 11 Technology Innovation C05)" of the MOLIT and the KAIA in Korea.

  16. Measurements of volatile organic compounds at a suburban ground site (T1 in Mexico City during the MILAGRO 2006 campaign: measurement comparison, emission ratios, and source attribution

    Directory of Open Access Journals (Sweden)

    D. M. Bon

    2011-03-01

    Full Text Available Volatile organic compound (VOC mixing ratios were measured with two different instruments at the T1 ground site in Mexico City during the Megacity Initiative: Local and Global Research Observations (MILAGRO campaign in March of 2006. A gas chromatograph with flame ionization detector (GC-FID quantified 18 light alkanes, alkenes and acetylene while a proton-transfer-reaction ion-trap mass spectrometer (PIT-MS quantified 12 VOC species including oxygenated VOCs (OVOCs and aromatics. A GC separation system was used in conjunction with the PIT-MS (GC-PIT-MS to evaluate PIT-MS measurements and to aid in the identification of unknown VOCs. The VOC measurements are also compared to simultaneous canister samples and to two independent proton-transfer-reaction mass spectrometers (PTR-MS deployed on a mobile and an airborne platform during MILAGRO. VOC diurnal cycles demonstrate the large influence of vehicle traffic and liquid propane gas (LPG emissions during the night and photochemical processing during the afternoon. Emission ratios for VOCs and OVOCs relative to CO are derived from early-morning measurements. Average emission ratios for non-oxygenated species relative to CO are on average a factor of ~2 higher than measured for US cities. Emission ratios for OVOCs are estimated and compared to literature values the northeastern US and to tunnel studies in California. Positive matrix factorization analysis (PMF is used to provide insight into VOC sources and processing. Three PMF factors were distinguished by the analysis including the emissions from vehicles, the use of liquid propane gas and the production of secondary VOCs + long-lived species. Emission ratios to CO calculated from the results of PMF analysis are compared to emission ratios calculated directly from measurements. The total PIT-MS signal is summed to estimate the fraction of identified versus unidentified VOC species.

  17. 上海地源热泵应用综论%SUMMARY OF APPLICATION OF GROUND-SOURCE HEAT PUMP IN SHANGHAI

    Institute of Scientific and Technical Information of China (English)

    唐益群; 张墨丹

    2011-01-01

    In this paper,application prospects of the ground-source heat pump (GSHP) in Shanghai were comprehensively analyzed from geothermal resources,geological conditions,technical and economic conditions and so on. The result showed that the GSHP has broad application in the future of Shanghai, because of not only the abundant occurrence condition (12 prospective areas of geothermal resources in Shanghai) but also being relatively more economical compared with the traditional air-conditioning system. Finally,some specific suggestions to application and development planning of GSHP in Shanghai were proposed by analyzing and exploring some potential problems of application of the GSHP.%本文从地热资源、地质条件、技术经济等方面分析了地源热泵在上海的应用前景.从地源热泵的赋存条件上来看,上海可分为12个地热资源远景区,而从技术经济的可行性分析上,相比传统的空调系统,也体现了其优越性;综合证明了地源热泵在上海广阔的应用前景.最后从科学合理开发利用浅层地温能以及地下空间稳定性角度,通过总结分析地热资源利用上潜在的一些问题,对上海地源热泵的利用和发展规划提出了具体建议.

  18. Measurements of volatile organic compounds at a suburban ground site (T1 in Mexico City during the MILAGRO 2006 campaign: measurement comparison, emission ratios, and source attribution

    Directory of Open Access Journals (Sweden)

    D. M. Bon

    2010-10-01

    Full Text Available Volatile organic compound (VOC mixing ratios were measured with two different instruments at the T1 ground site in Mexico City during the Megacity Initiative: Local and Global Research Observations (MILAGRO campaign in March of 2006. A gas chromatograph with flame ionization detector (GC-FID quantified 18 light alkanes, alkenes and acetylene while a proton-transfer-reaction ion-trap mass spectrometer (PIT-MS quantified 12 VOC species including oxygenated VOCs (OVOCs and aromatics. A GC separation system was used in conjunction with the PIT-MS (GC-PIT-MS to evaluate PIT-MS measurements and to aid in the identification of unknown VOCs. The VOC measurements are also compared to simultaneous canister samples and to two independent proton-transfer-reaction mass spectrometers (PTR-MS deployed on a mobile and an airborne platform during MILAGRO. VOC diurnal cycles demonstrate the large influence of vehicle traffic and liquid propane gas (LPG emissions during the night and photochemical processing during the afternoon. Emission ratios for VOCs and OVOCs are determined from early-morning enhancement ratios and compared to emission ratios calculated from the PMF results. Average emission ratios for non-oxygenated species relative to CO are on average a factor of 2 higher than measured for US cities. Emission ratios for OVOCs are estimated and compared to literature values the northeastern US and to tunnel studies in California. Positive matrix factorization analysis (PMF is used to provide insight into VOC sources and processing and to estimate OVOC emission ratios. Three PMF factors were distinguished by the analysis including the emissions from vehicles, the use of liquid propane gas and the production of secondary VOCs + long-lived species. The total PIT-MS signal was summed to estimate the fraction of identified vs. unidentified VOC species.

  19. DISSECTING THE POWER SOURCES OF LOW-LUMINOSITY EMISSION-LINE GALAXY NUCLEI VIA COMPARISON OF HST-STIS AND GROUND-BASED SPECTRA

    Energy Technology Data Exchange (ETDEWEB)

    Constantin, Anca; Castillo, Christopher A. [Department of Physics and Astronomy, James Madison University, Harrisonburg, VA 22807 (United States); Shields, Joseph C. [Department of Physics and Astronomy, Ohio University, Athens, OH 45701 (United States); Ho, Luis C. [Kavli Institute for Astronomy and Astrophysics, Peking University, Beijing 100871 (China); Barth, Aaron J. [Department of Physics and Astronomy, University of California, Irvine, CA 92697-4575 (United States); Filippenko, Alexei V. [Department of Astronomy, University of California, Berkeley, CA 94720-3411 (United States)

    2015-12-01

    Using a sample of ∼100 nearby line-emitting galaxy nuclei, we have built the currently definitive atlas of spectroscopic measurements of Hα and neighboring emission lines at subarcsecond scales. We employ these data in a quantitative comparison of the nebular emission in Hubble Space Telescope (HST) and ground-based apertures, which offer an order-of-magnitude difference in contrast, and provide new statistical constraints on the degree to which transition objects and low-ionization nuclear emission-line regions (LINERs) are powered by an accreting black hole at ≲10 pc. We show that while the small-aperture observations clearly resolve the nebular emission, the aperture dependence in the line ratios is generally weak, and this can be explained by gradients in the density of the line-emitting gas: the higher densities in the more nuclear regions potentially flatten the excitation gradients, suppressing the forbidden emission. The transition objects show a threefold increase in the incidence of broad Hα emission in the high-resolution data, as well as the strongest density gradients, supporting the composite model for these systems as accreting sources surrounded by star-forming activity. The narrow-line LINERs appear to be the weaker counterparts of the Type 1 LINERs, where the low accretion rates cause the disappearance of the broad-line component. The enhanced sensitivity of the HST observations reveals a 30% increase in the incidence of accretion-powered systems at z ≈ 0. A comparison of the strength of the broad-line emission detected at different epochs implies potential broad-line variability on a decade-long timescale, with at least a factor of three in amplitude.

  20. Binding Energies of Excitons in Square Quantum-Well Wires in the Presence of a Magnetic Field

    Institute of Scientific and Technical Information of China (English)

    张迎涛; 邸冰; 谢尊; 李有成

    2004-01-01

    The binding energies of the ground state of excitons in the GaAs/Ga1-xAlxAs square quantum-well wire in the presence of a magnetic field are investigated by using the variational method. It is assumed that the magnetic field is applied parallel to the axis of the wire. The calculations of the binding energy as a function of the wire size have been performed for infinite and finite confinement potentials. The contribution of the magnetic field makes the binding energy larger obviously, particularly for the wide wire, and the magnetic field is much more pronounced for the binding energy in a square quantum wire than that in a cylindrical quantum wire. The mismatch of effective masses between the well and the barrier is also considered in the calculation.

  1. Copper oxide transistor on copper wire for e-textile

    Science.gov (United States)

    Han, Jin-Woo; Meyyappan, M.

    2011-05-01

    A Cu2O-based field effect transistor was fabricated on Cu wire. Thermal oxidation of Cu forms Cu-Cu2O core-shell structure, where the metal-semiconductor Schottky junction was used as a gate barrier with Pt Ohmic contacts for source and drain. The device was coated with polydimethylsiloxane (PDMS) to protect from contamination and demonstrated as a humidity sensor. The cylindrical structure of the Cu wire and the transistor function enable embedding of simple circuits into textile which can potentially offer smart textile for wearable computing, environmental sensing, and monitoring of human vital signs.

  2. How to Ensure Long -term Stable Operation of Ground Source Heat Pump System for Heating Biogas Digester%如何保证地源热泵式沼气池加温系统长期稳定运行

    Institute of Scientific and Technical Information of China (English)

    张迪; 石惠娴; 朱洪光; 雷勇; 王卓

    2011-01-01

    针对地源热泵式沼气池加温系统中出现的冬夏季取排热不平衡从而影响其长期稳定运行的问题,本文在采取控制运行方式、增加辅助热源和蓄热系统解决方法的分析基础上,从充分利用可再生能源和地源热泵设备的角度出发,提出热泵供热和制冷互补模式与太阳能-地源热泵多功能互补模式,并对其可行性进行分析.%To address the problem of heat imbalance of soil between winter and summer led by ground source heat pump system for heating biogas digester and to ensure the system running more stably, effectively in a long time , the paper presents the advantages and disadvantages of controlling operation model and solar assisted ground source heat pump system with heat storage.What's more, the paper also proposes complementary models of heafing and cooling of heat pump and multifunctional system integrationg solar energy with ground source heat pump, and analyses the possibility of the above two solutions from the perspective of making full use of renewable energy and the equipment of ground soure heat pump.

  3. Analysis of Operating Characteristics of Hybrid Ground Source Heat Pump Assisted with Chiller%冷机辅助复合式地源热泵运行特性探析

    Institute of Scientific and Technical Information of China (English)

    周世玉; 崔文智

    2015-01-01

    Hybrid ground source heat pump system assisted with chiller is proposed in this paper, and also two kinds of operation scheme. System operation of 30 years is simulated using TRNSYS software. Compared with conventional ground source heat pump system, operating characteristics and the feasibility of the hybrid ground source heat pump system are analyzed from the ground temperature increase, system performance, energy consumption and also the technical and economic aspects.%提出了冷水机组和热泵机组分设的复合式地源热泵系统,并提出了两种运行方案。采用 TRNSYS软件模拟其30年的系统运行,并分别从地温增幅、系统性能、能耗及技术经济角度和常规地源热泵系统进行比较,分析了该复合式地源热泵系统的运行特性及其可行性。

  4. Temperature distributions in pavement and bridge slabs heated by using vertical ground-source heat pump systems - doi: 10.4025/actascitechnol.v35i4.15712

    Directory of Open Access Journals (Sweden)

    Asım Balbay

    2013-10-01

    Full Text Available Temperature distribution which occurs in pavement and bridge slabs heated for de-icing and snow melting during cold periods is determined by using vertical ground-source heat pump (GSHP systems with U-tube ground heat exchanger (GHE. The bridge and pavement models (slabs for de-icing and snow melting were constructed. A three-dimensional finite element model (FEM was developed to simulate temperature distribution of bridge slab (BS and pavement slab (PS. The temperature distribution simulations of PS and BS were conducted numerically by computational fluid dynamics (CFD program named ‘Fluent’. Congruence between the simulations and experimental data was determined.   

  5. Californium Recovery from Palladium Wire

    Energy Technology Data Exchange (ETDEWEB)

    Burns, Jon D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2014-08-01

    The recovery of 252Cf from palladium-252Cf cermet wires was investigated to determine the feasibility of implementing it into the cermet wire production operation at Oak Ridge National Laboratory’s Radiochemical Engineering Development Center. The dissolution of Pd wire in 8 M HNO3 and trace amounts of HCl was studied at both ambient and elevated temperatures. These studies showed that it took days to dissolve the wire at ambient temperature and only 2 hours at 60°C. Adjusting the ratio of the volume of solvent to the mass of the wire segment showed little change in the kinetics of dissolution, which ranged from 0.176 mL/mg down to 0.019 mL/mg. A successful chromatographic separation of 153Gd, a surrogate for 252Cf, from Pd was demonstrated using AG 50x8 cation exchange resin with a bed volume of 0.5 mL and an internal diameter of 0.8 cm.

  6. Californium Recovery from Palladium Wire

    Energy Technology Data Exchange (ETDEWEB)

    Burns, Jon D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2014-08-01

    The recovery of 252Cf from palladium-252Cf cermet wires was investigated to determine the feasibility of implementing it into the cermet wire production operation at Oak Ridge National Laboratory’s Radiochemical Engineering Development Center. The dissolution of Pd wire in 8 M HNO3 and trace amounts of HCl was studied at both ambient and elevated temperatures. These studies showed that it took days to dissolve the wire at ambient temperature and only 2 hours at 60°C. Adjusting the ratio of the volume of solvent to the mass of the wire segment showed little change in the kinetics of dissolution, which ranged from 0.176 mL/mg down to 0.019 mL/mg. A successful chromatographic separation of 153Gd, a surrogate for 252Cf, from Pd was demonstrated using AG 50x8 cation exchange resin with a bed volume of 0.5 mL and an internal diameter of 0.8 cm.

  7. Laser short pulse heating of metal nano-wires

    Science.gov (United States)

    Yilbas, B. S.; Al-Dweik, A. Y.

    2012-11-01

    Non-equilibrium energy transfer takes place in a solid substrate during a short-pulse laser irradiation and temperature field can be obtained analytically in the irradiated region. In the present study, laser short-pulse heating of metal nano-wire is considered and the analytical solution for two-dimensional axisymmetric nano-wire is presented. Since the absorption of the incident beam takes place in the skin of the irradiated surface, a volumetric heat source resembling the absorption process is incorporated in the analysis. Three different nano-wire materials are introduced in the analysis for the comparison reason. These include silver, chromium, and copper. It is found that temperature decay is gradual on the surface vicinity and temporal variation of the surface temperature follows almost the laser pulse intensity profile at the irradiated center.

  8. Double resonant wideband Purcell effect in wire metamaterials

    Science.gov (United States)

    Mirmoosa, M. S.; Kosulnikov, S. Yu; Simovski, C. R.

    2016-09-01

    In this paper, we theoretically show that a broadband resonant enhancement of emission may occur for infrared sources located in a polaritonic wire medium. The reason for this enhancement is the overlapping of two topological transitions of the wave dispersion in the medium. The first topological transition has been revealed as an effect inherent to polaritonic wire media at a certain frequency in the mid-infrared range. This work uncovers another topological transition for such wire media which holds at a higher frequency but still in the mid infrared. We show that the first transition frequency can be shifted towards the second one by variation of the design parameters. This shift enables a broadband resonant Purcell factor. We compare the results obtained for two orientations of a subwavelength electric dipole embedded into the wire medium—that along the optical axis and that perpendicular to it—and report on the resonant isotropic radiation enhancement. Also, we reveal the enhancement of radiation to the free space from a finite sample of the wire medium.

  9. 北方地区应用太阳能辅助土壤源热泵效能分析%Efficiency Analysis of Utilizing Solar-assisted Ground Source Heat Pump in the Northern China

    Institute of Scientific and Technical Information of China (English)

    赵金秀

    2015-01-01

    针对北方寒冷地区气候特点,指出了太阳能辅助土壤源热泵系统相对于单独的土壤源热泵或单独的太阳能应用的技术特点。对北方寒冷地区某学校综合楼建筑进行了太阳能辅助土壤源热泵系统设计;并针对该建筑采用太阳能辅助土壤源热泵系统、采用单独的土壤源热泵系统或采用传统采暖空调系统,从三者经济效益、社会效益、环境效益等方面进行了比较,从而体现了太阳能辅助土壤源热泵系统相对于单独的土壤源热泵系统或传统采暖空调系统的高效、经济、节能、环保等优异性。%For the cold climate characteristics of the Northern China, the paper introduces the technical characteristics of solar-assisted ground source heat pump system relative to the separate ground source heat pump system or the separate solar energy application. For a complex building of a university in the cold northern area, the solar -assisted ground source heat pump system is designed, and economic benefits, social benefits, environmental benefits and other aspects about using the solar-assisted ground source heat pump system or using the ground source heat pump system alone or using the traditional air conditioning system are compared, thus reflects the excellent efficiency, cost-saving and energy -saving characteristics, and environmental protection about the solar assisted ground source heat pump system.

  10. Ground Source Heat Pump Central Air Conditioning Systems Installed in Buildings%地源热泵中央空调系统在建筑中的应用与安装

    Institute of Scientific and Technical Information of China (English)

    吴尚瑜

    2014-01-01

    随着科学技术的不断发展,许多新型能源被研发出并投入使用,地源热泵就是其中的一种。地源热泵是利用浅层地热源研发而成的,并被应用到中央空调系统中。中央空调系统通过运用地源热泵,降低了成本,减少了污染,这在建筑业中起到了非常关键的作用。%With the continuous development of science and technology, many new sources of energy are developed and put into use;ground source heat pump is one of them. Ground source heat pump uses the shallow geothermal resources from R&D, and is applied to the central air conditioning system. Central air conditioning system through the use of ground source heat pump, reduce costs, reduce pollution, which has played a crucial role in the construction industry.

  11. Grounded theory.

    Science.gov (United States)

    Harris, Tina

    2015-04-29

    Grounded theory is a popular research approach in health care and the social sciences. This article provides a description of grounded theory methodology and its key components, using examples from published studies to demonstrate practical application. It aims to demystify grounded theory for novice nurse researchers, by explaining what it is, when to use it, why they would want to use it and how to use it. It should enable nurse researchers to decide if grounded theory is an appropriate approach for their research, and to determine the quality of any grounded theory research they read.

  12. Monitoring Groundwater Temperatures in a Shallow Urban Aquifer Before, During and After Installation of a Ground Source Heat System in Cardiff, U.K.

    Science.gov (United States)

    Patton, Ashley M.; Farr, Gareth J.; Boon, David P.; James, David R.; Williams, Bernard; Tucker, David; Harcombe, Gareth

    2016-04-01

    Exploitation of shallow urban aquifers, warmed by the Urban Heat Island Effect, is a relatively new concept in the U.K. An extensive groundwater temperature baseline monitoring network has been established for a shallow superficial aquifer in the city of Cardiff, U.K., to characterise groundwater temperatures and monitor the impacts of the first open-loop ground source heat pump (GSHP) installed in the city. In Spring 2014, temperature profiling was carried out at 1m depth intervals at 168 groundwater monitoring boreholes across Cardiff, establishing baseline groundwater temperatures within the shallow (form the first U.K. 2D city heat map. During the warmest time of year, Autumn 2014, a subset of boreholes were re-profiled to ascertain seasonal temperature variation, defining the Zone of Seasonal Fluctuation. Re-profiling was again carried out at these boreholes in Autumn 2015 to confirm these temperatures as normal for that time of year. By comparing Spring and Autumn profiles, the average depth to the base of the Zone of Seasonal Fluctuation was found to be 9.5mbgl. Two >100m boreholes showed the urban warming effect may extend to 80mbgl, before temperatures follow the predicted geothermal gradient. We term this the Zone of Anthropogenic Influence. After initial baseline temperatures were established, a site was selected for the installation of a shallow GSHP. Before installation work began, a monitoring network was set up to establish a temperature baseline for future GSHPs and identify any impacts on the thermal resource caused by removing ~2°C from the abstracted groundwater prior to reinjection into the aquifer. This comprised of 97 temperature loggers in 60 boreholes, including the abstraction and recharge boreholes and boreholes up and down gradient of the site. Some of these boreholes have multiple loggers at different depths, including the near-surface, but the majority of loggers were placed within the boreholes' slotted sections, below the base of the

  13. Simulating the thermal operating conditions in the thermal wells of ground-source heat-pump heat supply systems. Part I: Porous moisture freezing processes in soil

    Science.gov (United States)

    Vasilyev, G. P.; Peskov, N. V.; Lichman, V. A.; Gornov, V. F.; Kolesova, M. V.

    2015-08-01

    The mathematical models laid down in the new blocks of the INSOLAR.GSHP.12 software system simulating unsteady operating conditions of ground-source heat-pump (GSHP) heat supply systems are presented. The new model blocks take into account the effect the freezing of porous moisture in soil has on the GSHP system performance efficiency. Illustration is given to the need of taking into account the porous moisture freezing/thawing processes in soil, and the results from investigations devoted to the opening possibilities of constructing adaptive GSHP systems with controlled intensity of heat transfer in the soil-thermal well system are presented. The development of software simulating the porous moisture phase state variation processes in soil was preceded by development of mathematical equations representing the thermal conditions of soil body involving porous moisture freezing/thawing processes. A description of these equations is also given in the article. In constructing the mathematical model, the notion "effective thermal conductivity" of soil was introduced for taking into account the latent heat of phase transition that releases during the freezing of moisture. The above-mentioned effective thermal conductivity of soil involves two components: the soil thermal conductivity coefficient itself and an additional term modifying the thermal conductivity value for taking into account the influence of phase transition. For quantitatively evaluating the soil effective thermal conductivity component that takes into account the influence of phase transition, the soil freezing zone radius around the thermal well was determined. The obtained analytic solutions have been implemented in the form of computer program blocks, after which a "numerical experiment" was carried out for estimating the effect the porous moisture freezing/thawing processes have on the soil thermal conditions. It was demonstrated during that experiment that the soil thermal conductivities determined

  14. Stochastic ground motion simulation

    Science.gov (United States)

    Rezaeian, Sanaz; Xiaodan, Sun; Beer, Michael; Kougioumtzoglou, Ioannis A.; Patelli, Edoardo; Siu-Kui Au, Ivan

    2014-01-01

    Strong earthquake ground motion records are fundamental in engineering applications. Ground motion time series are used in response-history dynamic analysis of structural or geotechnical systems. In such analysis, the validity of predicted responses depends on the validity of the input excitations. Ground motion records are also used to develop ground motion prediction equations(GMPEs) for intensity measures such as spectral accelerations that are used in response-spectrum dynamic analysis. Despite the thousands of available strong ground motion records, there remains a shortage of records for large-magnitude earthquakes at short distances or in specific regions, as well as records that sample specific combinations of source, path, and site characteristics.

  15. 29 CFR 1926.954 - Grounding for protection of employees.

    Science.gov (United States)

    2010-07-01

    ..., DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Power Transmission and... the new lines or equipment. (c) Communication conductors. Bare wire communication conductors on power... operation of protective devices. (i) Grounding to tower. Grounding to tower shall be made with a tower...

  16. The HayWired earthquake scenario

    Science.gov (United States)

    Detweiler, Shane T.; Wein, Anne M.

    2017-04-24

    ForewordThe 1906 Great San Francisco earthquake (magnitude 7.8) and the 1989 Loma Prieta earthquake (magnitude 6.9) each motivated residents of the San Francisco Bay region to build countermeasures to earthquakes into the fabric of the region. Since Loma Prieta, bay-region communities, governments, and utilities have invested tens of billions of dollars in seismic upgrades and retrofits and replacements of older buildings and infrastructure. Innovation and state-of-the-art engineering, informed by science, including novel seismic-hazard assessments, have been applied to the challenge of increasing seismic resilience throughout the bay region. However, as long as people live and work in seismically vulnerable buildings or rely on seismically vulnerable transportation and utilities, more work remains to be done.With that in mind, the U.S. Geological Survey (USGS) and its partners developed the HayWired scenario as a tool to enable further actions that can change the outcome when the next major earthquake strikes. By illuminating the likely impacts to the present-day built environment, well-constructed scenarios can and have spurred officials and citizens to take steps that change the outcomes the scenario describes, whether used to guide more realistic response and recovery exercises or to launch mitigation measures that will reduce future risk.The HayWired scenario is the latest in a series of like-minded efforts to bring a special focus onto the impacts that could occur when the Hayward Fault again ruptures through the east side of the San Francisco Bay region as it last did in 1868. Cities in the east bay along the Richmond, Oakland, and Fremont corridor would be hit hardest by earthquake ground shaking, surface fault rupture, aftershocks, and fault afterslip, but the impacts would reach throughout the bay region and far beyond. The HayWired scenario name reflects our increased reliance on the Internet and telecommunications and also alludes to the

  17. Analysis on the construction technology of heat exchanger of Ground-Source Heat Pump(GSHP) system%土壤源热泵换热器施工工艺分析

    Institute of Scientific and Technical Information of China (English)

    王祁生

    2011-01-01

    以实际工程为背景,研究了土壤源热泵技术的工作原理,详细阐述了土壤源热泵换热器施工工艺和操作要点以及注意事项,旨在推广土壤源热泵技术的应用,实现节能环保目标。%Taking actual engineering as the background,it studies the working principle of Ground-Source Heat Pump technology,describes the cosntruciton technology and operation points and attentions of heat exchanger of Ground-Source Heat Pump,with a view to promot

  18. 30 CFR 57.12047 - Guy wires.

    Science.gov (United States)

    2010-07-01

    ... Underground § 57.12047 Guy wires. Guy wires of poles supporting high-voltage transmission lines shall meet the... “Safety Rules for the Installation and Maintenance of Electric Supply and Communication Lines”...

  19. Anode wire aging tests with selected gases

    Energy Technology Data Exchange (ETDEWEB)

    Kadyk, J.; Wise, J.; Hess, D.; Williams, M. (Lawrence Berkeley Lab., CA (United States))

    1990-04-01

    As a continuation of earlier wire aging investigations, additional candidates for wire chamber gas and wire have been tested. These include the gases: argon/ethane, HRS gas, dimethyl ether, carbon dioxide/ethane, and carbon tetrafluoride/isobutane. Wires used were: gold- plated tungsten, Stablohm, Nicotin, and Stainless Steel. Measurements were made of the effects upon wire aging of impurities from plumbing materials or contamination from various types of oil. Attempts were made to induce wire aging by adding measured amounts of oxygen and halogen (methyl chloride) with negative results. In this paper, the possible role of electronegativity in the wire aging process is discussed, and measurements of electronegativity are made with several single carbon Freons, using both an electron capture detector and a wire chamber operating with dimethyl ether.

  20. Evaluation of high temperature stranded hookup wire

    Science.gov (United States)

    Donnelly, J. H.; Moore, H. J., Jr.

    1967-01-01

    Tests are performed on wire and insulation materials to determine selection for electronic space assemblies. Wire characteristics of tensile strength, flexibility, conductivity, and general workability are tested. Knowledge of the advantages and limitations of these materials should prevent overspecification.

  1. TCP/IP Over SpaceWire

    Science.gov (United States)

    Mills, S.; Parkes, S.

    The SpaceWire standard defines a network designed for handling payload data and control information onboard a spacecraft. Among the goals of SpaceWire are re-usability and reliability. The use of network protocols on top of SpaceWire is expected to enhance the already rich re-usability and reliability characteristics of SpaceWire. The Space Systems Research Group at the University of Dundee have developed software to allow data to be sent over SpaceWire using standard network protocols such as TCP/IP, as part of a program of work looking at network protocols for SpaceWire. This paper describes network protocols and their relationship to SpaceWire, introduces software written to allow network protocols to be layered on to SpaceWire, describes the research behind the development of this software, and gives results of some tests and observations made using the software.

  2. Optimization for Complex System of Ground Source Heat Pump Based on TRNSYS%基于 TRNSYS 的地源热泵复合系统运行策略的优化

    Institute of Scientific and Technical Information of China (English)

    程晓曼; 刘金祥; 陈高峰; 李帅

    2015-01-01

    TRNSYS is utilized to establish the composite system model of ground source heat pump and cooling tower, and simulate running situation of the composite ground source heat pump system in of-fice building for a long time in the hot summer and cold winter region. On the basis of theoretical analysis and the measured data validation, considering weather conditions, cooling tower open time, soil factors such as heat dissipation, the paper analyzes the joint operation characteristics of cooling tower and the ground source heat pump in local office building. Opening the cooling tower at night with normal operation mode of the ground source heat pump during the day is proposed for office building in the refrigeration period.%利用 TRNSYS 瞬时仿真模拟软件建立地源热泵与冷却塔复合系统模型,模拟出夏热冬冷地区办公楼地源热泵复合系统长期运行情况。在理论分析和实测数据验证的基础上,考虑气象条件、冷却塔开启时间、土壤散热等因素,分析该地区办公建筑冷却塔与地源热泵联合运行的特点;提出制冷期办公建筑夜间开启冷却塔蓄冷、白天地源热泵正常运行的模式。

  3. Novel Wiring Technologies for Aerospace Applications

    Science.gov (United States)

    Gibson, Tracy L.; Parrish, Lewis M.

    2014-01-01

    Because wire failure in aerospace vehicles could be catastrophic, smart wiring capabilities have been critical for NASA. Through the years, researchers at Kennedy Space Center (KSC) have developed technologies, expertise, and research facilities to meet this need. In addition to aerospace applications, NASA has applied its knowledge of smart wiring, including self-healing materials, to serve the aviation industry. This webinar will discuss the development efforts of several wiring technologies at KSC and provide insight into both current and future research objectives.

  4. Further Studies Of Hot-Wire Anemometry

    Science.gov (United States)

    Mckenzie, Robert; Logan, Pamela; Bershader, Daniel

    1990-01-01

    Report discusses factors affecting readings of hot-wire anemometer in turbulent supersonic boundary layer. Represents extension of work described in "Hot-Wire Anemometry Versus Laser-Induced Fluorescence" (ARC-11802). Presents theoretical analysis of responses of hot-wire probe to changes in flow; also compares measurements by hot-wire probe with measurements of same flows by laser-induced fluorescence (LIF).

  5. Different mechanical properties in Seldinger guide wires

    Directory of Open Access Journals (Sweden)

    Wolfram Schummer

    2015-01-01

    Full Text Available Background and Aims: Most central venous catheters are placed using Seldinger guide wires. EN ISO 11070 is the guideline for testing guide wire flexing performance and tensile strength, and we can safely assume that guide wires in use meet these requirements. Unfortunately, EN ISO 11070 guidelines do not reflect the clinical requirements and we continue to see mechanical failures and their associated complications. Material and Methods: This in vitro study was performed in an accredited laboratory. With regard to flexing, we: (1 Established the minimum flexing performance needed to meet clinical requirements, (2 developed flexing performance tests which mimic clinical requirement, and (3 evaluated the mechanical properties of various guide wires relative to these requirements. With regard to tensile strength, we used the testing method prescribed in ISO 11070, but did not end the test at 5 Newton (N. We continued until the guide wire was damaged, or we reached maximum tractive force. We then did a wire-to-wire comparison. We examined two basic wire constructions, monofil and core and coil. Results: Tensile strength: All wires tested, except one, met EN ISO 11070 requirements for 5 N tensile strength. The mean of the wire types tested ranged from 15.06 N to 257.76 N. Flexing performance: None of the wires kinked. The monofil had no evidence of bending. Two core/coil wires displayed minor bending (angle 1.5°. All other wires displayed bending angles between 22.5° and 43.0°. Conclusion: We recommend that: (1 Clinicians use guide wires with high-end mechanical properties, (2 EN ISO 11070 incorporate our flexing test into their testing method, raise the flexing requirement to kink-proof, (3 and raise the tensile strength requirement to a minimum of 30 N, and (3 all manufacturers and suppliers be required to display mechanical properties of all guide wire, and guide wire kits sold.

  6. One century of Kirschner wires and Kirschner wire insertion techniques : A historical review

    NARCIS (Netherlands)

    Franssen, Bas B. G. M.; Schuurman, Arnold H.; Van der Molen, Aebele Mink; Kon, Moshe

    2010-01-01

    A century ago, in 1909, Martin Kirschner (1879-942) introduced a smooth pin, presently known as the Kirschner wire (K-wire). The K-wire was initiallly used for skeletal traction and is now currently used for many different goals. The development of the K-wire and its insertion devices were mainly in

  7. 太中银铁路沿线站区地源热泵运行与维护管理%On operation of ground source heat pump and maintenance management at stations along Taiyuan-Zhongwei-Yinchuan Railway

    Institute of Scientific and Technical Information of China (English)

    廉小洁

    2015-01-01

    在对地源热泵工作理论分析的基础上,结合太中银铁路太原局管段五站地埋管地源热泵实际使用中存在的管路断裂、换热量不足等问题,从系统运行与维护管理角度提出了一些改进建议,为地埋管地源热泵系统的推广应用提供了技术支持。%Based on the theoretic analysis of the ground source heat pump,the paper points out some improvement suggestions from the system op-eration and maintenance by combining with pipeline fracture,shortage of heat problems in the uses of the ground source heat pump at the five sta-tion of Taiyuan Bureau Segment along Taiyuan-Zhongwei-Yinchuan Railway,so as to provide some technical support for the application of the bur-ied ground source heat pump system.

  8. Design And Conclusion of Ground-source Heat Pump System of a Villa in Jiangyin%江阴某别墅地源热泵空调系统设计与总结

    Institute of Scientific and Technical Information of China (English)

    戴银宝

    2016-01-01

    The ground-source heat pump system is a highly efficient energy -saving environmental protection air conditioning system, in recent years it has been heavily promoted by the people .This paper, taking a ground -source heat pump system design of a villa for an example , analyses the application of the ground -source heat pump system in hvac design , in order to provide relevant experience and basis for similar projects .%地源热泵空调系统由于是一种高效节能环保型的空调系统,近年来已经受到人们的极大重视。本文以江阴某别墅地源热泵空调系统设计为例,浅析地源热泵空调系统在暖通设计中的应用,以求能为类似项目提供相关的经验及依据。

  9. 太阳能-土壤源热泵复合系统优化与性能分析%System Optimization and Performance Analysis of Solar Energy and Ground-source Heat Pump Hybrid System

    Institute of Scientific and Technical Information of China (English)

    丁力勤

    2016-01-01

    本文利用瞬时系统模拟软件(Trnsys)搭建了常规土壤源热泵系统及太阳能-土壤源热泵并联复合式系统的模型,并根据不同集热器单位面积流量和水箱体积等参数进行了模拟计算。结果表明,土壤源热泵系统性能系数达3.6~3.8,具有明显的节能优势。%The models of ground-source heat pump system and the solar energy and ground-source heat pump shunt-wound hybrid system have been built by transient system (Trnsys) simulation software, and the simulation calculation has been processed according to the flow rate per unit area and water tank volume for different collectors. According to the simulation results, the coefficient of performance of the ground-source heat pump system is 3.6~3.8, and the system has advantages on energy saving.

  10. Buried Tubes of Ground Source Heat Pump for Villa and Its Economic Analysis%小洋房地源热泵地埋管介绍及系统经济性分析

    Institute of Scientific and Technical Information of China (English)

    杨大章; 魏林; 李帆; 顾士元

    2013-01-01

      介绍了上海理工大学3栋历史建筑(小洋房)的地源热泵地埋管系统,并对地源热泵运行的能耗和经济性进行了分析.分析结果表明,与分体空调相比,地源热泵节能率达到27.3%,投资回收期为18.3年.%The buried tubes of the ground source heat pump system in three historic buildings of the University of Shanghai for Science and Technology(villa) were described, with analysis on running energy consumption and cost of the ground source heat pump. The results show that energy-saving rate of ground source heat pump is 27.3%, less than split air-condition, with payback period of 18.3 years.

  11. The Energy Saving and Techno-economic Analysis of Ground Source Heat Pump in Changchun%长春地区土壤源热泵的节能与经济技术性分析

    Institute of Scientific and Technical Information of China (English)

    甄勃; 焦迎新

    2011-01-01

    在能源和环保成为影响和制约人类生存、发展的背景下,介绍了土壤源热泵的工作原理,结合工程实例,分析了土壤源热泵系统的节能、经济性及技术性,给出我国严寒地区土壤源热泵大规模开发及工程应用的可行性建议.%The energy and environmental protection becomes background influenced and restricted to human survival and development,the work principle of ground-source heat pump is introduced in the paper.Combined with engineering example,energy,technology and economy,analyses of ground-source heat pump system is implemented,feasibility suggestions of the large-scale development and engineering application by ground-source heat pump are provided in cold region.

  12. Transport of an arbitrary near-field component with an array of tilted wires

    Energy Technology Data Exchange (ETDEWEB)

    Morgado, Tiago A; Silveirinha, Mario G [Departamento de Engenharia Electrotecnica, Universidade de Coimbra, Instituto de Telecomunicacoes, Polo II, 3030 Coimbra (Portugal)], E-mail: mario.silveirinha@co.it.pt

    2009-08-15

    In this work, we investigate the possibility of near-field transport using an array of tilted metallic wires. It is demonstrated that consistent with the results reported in Belov et al (2006 Phys. Rev. B 73 033108), which describes subwavelength imaging by an array of metallic wires normal to the interface, the setup considered here may enable the transport of the subwavelength details of a given source through an oblique projection. The array of tilted wires permits the transfer of the electric field component parallel to the wires at the image plane, even when there is no electric field normal to interface, and thus the manipulation of other near-field components (i.e. other wave polarizations) that are not accessible with the usual setup of wires normal to the interface. The emergence of negative refraction due to the extreme anisotropy of structured material is also demonstrated.

  13. Proportional counters aged anode wire recovering using an 80%CF4 + 20%CO2 gas mixture

    CERN Document Server

    Gavrilov, Gennady; Conti, Richard; Fetisov, Andrey; Maysuzenko, Dmitry; Shvecova, Natalia; Vakhtel, Victor

    2011-01-01

    A technique to recover a gas proportional counter having an aged anode wire using a glow discharge in an 80%CF4 + 20%CO2 gas mixture has been developed and tested. Studies of aging effects were carried out under sustained irradiation by an intense 90Sr -source of the straw proportional counters operated with a 60%Ar + 30%CO2 + 10%CF4 gas mixture. Special attention was paid to the aging mechanism of the anode wires. Our experience showed that using a given gas mixture the swelling of the anode wires is a typical mode of aging that leads to degradation of the gas gain. The proposed method of recovery provided a complete restoration of the gas gain and the signal amplitude in the damaged zone of the wire. SEM/XEM analysis confirmed successful cleaning WOx deposits from the wire surface. The application of this method to recover the aged gaseous detectors in real experimental conditions is discussed.

  14. Getting "Wired" for McLuhan's Cyberculture.

    Science.gov (United States)

    McMurdo, George

    1995-01-01

    Examines the introduction of the computing magazine, "Wired", into the United Kingdom's (UK) market. Presents conversations with the founder and editorial staff of the UK edition, and discusses the accessibility of "Wired" via the World Wide Web. Describes 10 articles from United States "Wired" back-issues and…

  15. Generalized additional boundary conditions for wire media

    Energy Technology Data Exchange (ETDEWEB)

    Maslovski, Stanislav I; Morgado, Tiago A; Silveirinha, Mario G [Departamento de Engenharia Electrotecnica, Instituto de Telecomunicacoes, Universidade de Coimbra, Polo II, 3030-290 Coimbra (Portugal); Kaipa, Chandra S R; Yakovlev, Alexander B, E-mail: stas@co.it.p [Department of Electrical Engineering, University of Mississippi, University, MS 38677-1848 (United States)

    2010-11-15

    We generalize additional boundary conditions (ABCs) for wire media by including arbitrary wire junctions with impedance loading. Special attention is given to the conditions at the interface of two uniaxial wire media with metallic patches at the junction. The derived ABCs are validated against full-wave numerical simulations.

  16. 75 FR 4584 - Wire Decking From China

    Science.gov (United States)

    2010-01-28

    ... COMMISSION Wire Decking From China AGENCY: United States International Trade Commission. ACTION: Scheduling... retarded, by reason of subsidized and less-than-fair-value imports from China of wire decking, provided for..., producers, or exporters in China of wire decking, and that such ] products are being sold in the...

  17. 49 CFR 393.28 - Wiring systems.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Wiring systems. 393.28 Section 393.28 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL MOTOR CARRIER SAFETY... NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical Wiring § 393.28 Wiring systems...

  18. Optimization of ground source heat pumps systems through the implementation of hybrid systems; Optimizacion de las instalaciones de bomba de calor geotermica mediante la implementacion de sistemas hibridos

    Energy Technology Data Exchange (ETDEWEB)

    Magraner, T.; Quilis, M. S.; Martinez, S.

    2009-07-01

    One of the fundamental aspects to consider in the design of a ground heat pump system is the heat balance in the ground since thermal saturation of the ground produces a decreasing of the performance of the system throughout its useful life. The hybrid geothermal system which combined geothermal heat pump system with other systems for generation or dissipation energy are very suitable for balancing the heat exchanger meters needed for the proper functioning of the system, important aspect to reduce costs and achieve attractive return periods of the initial investment. Energesis Ingenieria has developed and implemented in two office buildings, a design of hybrid systems based on the combination of a geothermal heat pump and air-condensed units (dry coolers) that can ensure energy efficiencies comparable to geothermal pure systems, reducing substantially the investment cost. (Author) 5 refs.

  19. Grounded cognition.

    Science.gov (United States)

    Barsalou, Lawrence W

    2008-01-01

    Grounded cognition rejects traditional views that cognition is computation on amodal symbols in a modular system, independent of the brain's modal systems for perception, action, and introspection. Instead, grounded cognition proposes that modal simulations, bodily states, and situated action underlie cognition. Accumulating behavioral and neural evidence supporting this view is reviewed from research on perception, memory, knowledge, language, thought, social cognition, and development. Theories of grounded cognition are also reviewed, as are origins of the area and common misperceptions of it. Theoretical, empirical, and methodological issues are raised whose future treatment is likely to affect the growth and impact of grounded cognition.

  20. Analysis of an Underground Vertical Electrically Small Wire Antenna

    Directory of Open Access Journals (Sweden)

    Shuwei Dong

    2015-01-01

    Full Text Available The problem considered is a vertical electrically small wire antenna located underground, which transmits electromagnetic signals to the ground. Getting Green’s function of the vertical dipole underground was the first step to calculate this issue. A quasistatic situation was considered to make an approximation on Sommerfeld integral for easy solution. The method of moments was used to solve the current distribution on the antenna surface at different frequencies, which laid a good foundation for obtaining the electric field of the antenna. Then the axial and radial components of the electric field with the radial distance on the ground were investigated, as well as the voltage received on the ground. Furthermore, the influence of the frequency and stratum parameters on current and electric field was studied to understand the variation clearly.

  1. Electrostatic Surface Trap for Cold Polar Molecules with a Charged Circular Wire

    Institute of Scientific and Technical Information of China (English)

    MA Hui; ZHOU Bei; LIAO Bin; YIN Jian-Ping

    2007-01-01

    We propose a novel scheme to trap cold polar molecules on the surface of an insulating substrate (i.e. a chip) by using an inhomogeneous electrostatic field, which is generated by the combination of a circular charged wire (a ring electrode) and a grounded metal plate. The spatial distributions of the electrostatic field from the above charged wire layout and its Stark potentials for CO molecules are calculated. Our study shows that when the voltage applied to the wire is U = 15 kV, a ring radius is R = 5 mm, the thickness of the insulating substrate is b = 5 mm, and a wire radius is r = 1 mm, the maximum efficient trapping potential (i.e., as equivalent temperature) for CO molecules is greater than 141.7mK, which is high enough to trap cold polar molecules with a temperature of 50 mK in the low-field-seeking states.

  2. Feasibility Analysis of Applying Ground-source Heat Pump System in Huaian Urban Planning Area%淮安城市规划区地源热泵系统应用可行性分析

    Institute of Scientific and Technical Information of China (English)

    汪名鹏

    2012-01-01

    介绍了淮安城市规划区水文地质条件、岩土体结构、地温场特征以及岩土层的热物理参数,结合地下水地源热泵系统和垂直地埋管地源热泵系统的应用特点,对两种类型的地源热泵系统在淮安规划区应用的可行性进行了分析.结果表明城市规划区面积约97.5%的区域不适宜应用地下水地源热泵系统,仅在规划区西北角小范围内较适宜应用;而垂直地埋管地源热泵系统可适宜在规划区内大面积推广应用,地埋管深度一般100m左右;最后对规划区两种类型的地源热泵系统应用过程中需要注意的几个问题进行了阐述,为淮安城市规划区地源热泵系统规划与试点工作提供了科学依据.%This paper introduces the hydrogeological conditions, rock mass structure, characteristics of ground temperature field and thermophysical parameters of rock mass in urban planning area of Huaian. Combining with the features of groundwater source heat pump system and vertical ground pipe heat pump system, the feasibility application of two kinds of heat pump systems in Huaian planning area is analyzed. The results show that the groundwater source heat pump system is unsuitable for urban planning area about 97.5% ,only the northwest corner of the planning area is less suitable for groundwater source heat pump system;the urban planning area is suitable for vertical ground pipel heat pump system with a large area of the promotion, the depth of underground pipe is about 100m. Finally, some issues to which much attention should be described in the course of application two types of ground-source heat pump systems in urban planning area of Huaian, and it provides scientific references for planning and pilot of application two types of ground-source heat pump systems in urban planning area of Huaian.

  3. Energy Deposition in a Septum Wire

    CERN Document Server

    Ferioli, G; Knaus, P; Koopman, J; CERN. Geneva. SPS and LHC Division

    2001-01-01

    The present note describes a machine development (MD) aimed to confirm experimentally the need for protection of the extraction wire septum ZS in SPS long straight section LSS6 during LHC operation. Single wires identical to the ones mounted on the extraction septum were fixed on a fast wire scanner and put into the beam path. The beam heated the wire until it broke after a measured number of turns. The maximum single shot intensity the septum wires could withstand was thus calculated and compared with simulation results.

  4. Directional growth of polypyrrole and polythiophene wires

    Science.gov (United States)

    Thapa, Prem S.; Yu, Deok Jin; Wicksted, James P.; Hadwiger, Jeffrey A.; Barisci, Joseph N.; Baughman, Ray H.; Flanders, Bret N.

    2009-01-01

    This work establishes an innovative electrochemical approach to the template-free growth of conducting polypyrrole and polythiophene wires along predictable interelectrode paths up to 30 μm in length. These wires have knobby structures with diameters as small as 98 nm. The conductivity of the polypyrrole wires is 0.5±0.3 S cm-1; that of the polythiophene wires is 7.6±0.8 S cm-1. Controlling the growth path enables fabrication of electrode-wire-target assemblies where the target is a biological cell in the interelectrode gap. Such assemblies are of potential use in cell stimulation studies.

  5. Clinical bending of nickel titanium wires

    Directory of Open Access Journals (Sweden)

    Stephen Chain

    2015-01-01

    Full Text Available Since the evolution and the involvement of Nickel Titanium wires in the field of Orthodontics. The treatment plan has evolved with the use of low force Nickel Titanium wires. Because of their high springback, low stiffness, they are the key initial wires in leveling and alignment but have poor formability. Since poor formability limits its ability to create variable arch forms thus; limits the form of treatment. We have devised a method to bend the Nickel Titanium wires to help in our inventory but also customized the wire according to the treatment.

  6. Comparison of 85KR and 3H Apparent Ground-Water Ages for Source Water Vulterability in the COLLYER RIVER CATCHMENT, MAINE

    Science.gov (United States)

    Apparent ground-water ages as determined by the noble gas isotope 85Kr and the water isotope 3H are compared. Refined gas extraction methodology at the wellhead permits efficient collection of Kr for 85Kr isotope enrichment. 85Kr isoch...

  7. Composite wire plasma formation and evolution

    Energy Technology Data Exchange (ETDEWEB)

    Spielman, R.B.

    2000-01-01

    The detailed understanding of the formation and evolution of plasma from rapidly heated metallic wires is a long-standing challenge in the field of plasma physics and in exploding wire engineering. This physical process is made even more complicated if the wire material is composed of a number of individual layers. The authors have successfully developed both optical and x-ray backlighting diagnostics. In particular, the x-ray backlighting technique has demonstrated the capability for quantitative determination of the plasma density over a wide range of densities. This diagnostic capability shows that the process of plasma formation is composed of two separate phases: first, current is passed through a cold wire and the wire is heated ohmically, and, second, the heated wire evolves gases that break down and forms a low-density plasma surrounding the wire.

  8. Influence of voltage source converter grounding mode on DC distribution system%电压源换流器接地方式对直流配电系统的影响

    Institute of Scientific and Technical Information of China (English)

    鲁国正; 高亮; 梁智敏

    2016-01-01

    For the low voltage direct current (LVDC) distribution system, the advantages and disadvantages of the different grounding modes of the voltage source converterare analyzed and compared. In the converter capacitor directly grounding and high resistance grounding mode, the converter AC outlet of asymmetric fault characteristics and DC line pole grounding faultcharacteristicsare analyzed,and the LVDC electromagnetic transient model is established and studied by simulation. Comparison of the system transient performance under different operating conditions shows that voltage source converter capacitor high resistance grounding mode is better than the direct grounding way. High resistance grounding to limit fault current is more favorable, and it is also beneficial to the rapid recovery after the DC power distribution system is eliminated, which lays the foundation for the protection scheme of DC power distribution system in the future.%针对低压直流(Low Voltage Direct Current, LVDC)配电系统分析比较了电压源换流器不同接地方式的优缺点。分别在换流器电容中点直接接地和高阻接地方式下,对换流器交流出口处不对称故障特性和直流线路单极接地故障特性进行了分析,并建立LVDC电磁暂态模型进行了仿真研究。对比系统不同工况下的暂态性能可知,电压源换流器电容中点高阻接地方式优于直接接地方式。高阻接地的方式对限制故障电流更为有利,同时也有利于直流配电系统故障消除后的快速恢复,这为未来直流配电系统保护方案的配置奠定了基础。

  9. Preparation of uncladded YBCO wires

    Science.gov (United States)

    Grader, G.; Cadoche, L.; Shter, G.

    1993-04-01

    Wires of YBCO, 1-5 mm in diameter, have been obtained by extrusion of an oxalate derived powder mixed with polyvinyl butyral (PVB) and two phthalate plasticizers. The densification and transport properties of the wires were investigated at various organic loading conditions. For YBCO powder prepared by oxalate coprecipitation and calcined at 930°C, the maximal strength, relative density and Jc were 20MPa, 92% and 400A/cm 2, respectively. Results show that after a 4-hour sintering at 955°C the tensile strength, density, and Jc are all maximized at a binder content of 3-4 wt.%. The loading of up to 10 wt.% dibutyl phthalate (DBP) plasticizer (in the binder) has little effect on the properties. Beyond this loading a drastic drop in Jc is observed. The densification was very poor for sinterings below 950°C, which was reflected by a lower critical current.

  10. 49 CFR 236.108 - Insulation resistance tests, wires in trunking and cables.

    Science.gov (United States)

    2010-10-01

    ... dry. Insulation resistance tests shall be made between all conductors and ground, and between conductors in each multiple conductor cable, and between conductors in trunking, when wires or cables are... annually. (c) In no case shall a circuit be permitted to function on a conductor having an...

  11. 49 CFR 234.267 - Insulation resistance tests, wires in trunking and cables.

    Science.gov (United States)

    2010-10-01

    ... be made between all conductors and ground, between conductors in each multiple conductor cable, and between conductors in trunking. Insulation resistance tests shall be performed when wires, cables, and... be made annually. (d) A circuit with a conductor having an insulation resistance of less than...

  12. 46 CFR 169.680 - Installation of wiring for power and lighting circuits.

    Science.gov (United States)

    2010-10-01

    ... the following requirements: (1) Each opening through which conductors enter must be adequately closed... noncurrent carrying conductor. (f) On a nonmetallic vessel, where a ground plate is provided for radio... may be decreased to not less than 1 inch. (l) Each conductor, except a fixture wire within a box,...

  13. Electron-phonon interaction in a semiconductor quantum wire embedded into the semiconductor medium

    CERN Document Server

    Zharkoj, V P

    2002-01-01

    The renormalization of electron ground state energy due to the different types of interaction with confined (L) and interface (I) phonons in a semiconductor cylindrical quantum wire (QW) embedded into the semiconductor medium by the example of a HgS/CdS nanosystem.

  14. Insulator and Clerance Requirements in Overhead Line Transmission Systems without Shield Wires

    DEFF Research Database (Denmark)

    Sørensen, Thomas Kjærsgaard; Holbøll, Joachim

    2008-01-01

    This paper theoretically examines the required insulation lengths and clearances in 400 kV overhead line systems when not making use of ground wires as lightning protection. The influence of lightning strikes to the system is investigated based on dynamic transmission line simulations of a 400 kV...

  15. Insulator and Clerance Requirements in Overhead Line Transmission Systems without Shield Wires

    DEFF Research Database (Denmark)

    Sørensen, Thomas Kjærsgaard; Holbøll, Joachim

    2008-01-01

    This paper theoretically examines the required insulation lengths and clearances in 400 kV overhead line systems when not making use of ground wires as lightning protection. The influence of lightning strikes to the system is investigated based on dynamic transmission line simulations of a 400 k...

  16. 29 CFR 1910.305 - Wiring methods, components, and equipment for general use.

    Science.gov (United States)

    2010-07-01

    ... STOO, except for the wiring of chain-supported lighting fixtures and supply cords for portable lamps... electrical noise (electromagnetic interference) of the grounding circuit, an equipment enclosure supplied by a branch circuit may be isolated from a raceway containing circuits supplying only that equipment...

  17. Thermoprocessing and wire drawing behaviour of ultra high strength steel wires

    Directory of Open Access Journals (Sweden)

    S.S. Bargujer

    2016-09-01

    Full Text Available The thermo-processing of piano wire rods is carried out in the lead bath. This experimentation is carried out under industrial conditions. The investigation is done to examine the effect of austenitic time, lead bath time and wire diameter on mechanical properties of lead patented wire. The Taguchi technique is adopted for optimization of thermo-processing of hypereutectoid steel wires. The lead patented wire of diameter 7.00 mm is cold drawn in a sequence of conical converging dies. The best pass schedule of lead patented piano wire is obtained by optimizing the ultimate tensile strength and torsion strength of cold drawn wire. The characterization of wire drawing behaviour of lead patented wires is carried out using optical microscopy, scanned electron microscopy and X-ray diffraction analysis techniques.

  18. SpaceWire Satellite Usage

    Science.gov (United States)

    2013-03-01

    Figure 1. SpaceWire Topologies 309 Report Documentation Page Form ApprovedOMB No. 0704-0188 Public reporting burden for the collection of...RS422 Hosted Payload data interface Joint  Architeccture  Standards Sandia,  LANL control interface; backplane sRIO, PCIe Common standards for joint

  19. Concept of porous wire anemometer

    Energy Technology Data Exchange (ETDEWEB)

    Afgan, N.H.; Pereira, J.C. [Inst. Superior Tecnico, Lisbon (Portugal); Leontiev, A.I.; Puzach, S.V. [Moscow Technical Univ. (Russian Federation)

    1997-05-01

    The paper presents a new scheme of the anemometer sensing element for the gas mean and fluctuation velocity measurement. The sensing element is a porous tube with gas suction through porous tube wall. The outside surface of the porous tube is at the gas temperature. The analysis, based on the heat balance at steady and unsteady state is performed in order to define the sensitivity and time constant of the porous sensing element. Two cases are considered, namely, the constant current and constant temperature anemometer. Comparison is made with the solid wire anemometer and shown that the proposed porous sensing element can have sensitivity four times higher than the standard hot wire anemometer with the same geometrical dimensions. With the respective selection of the physical properties of the sensing element, it could be possible to obtain higher frequency range of the measurement. Particular attention is devoted to the low gas velocity measurement. It is recognized that the minimum gas velocity to be measured with the solid hot wire anemometer is determined by the local heat transfer coefficient. For the low gas velocity, it was proved that the minimum is around .20 cm/sec. The proposed concept of the sensing element can be used for the very low velocity measurement due to the higher sensitivity obtained by the porous sensing element.

  20. Simulation of Wire-Array Z Pinches with ALEGRA

    Science.gov (United States)

    Chantrenne, Sophie; Bliss, David; Cochrane, Kyle; Coverdale, Christine; Deeney, Chris; Hall, Clint; Haill, Thomas; Jones, Brent; Lepell, Paul; Oliver, Bryan; Sinars, Daniel

    2006-10-01

    Wire-array z pinches provide the x-ray radiation drive for Inertial Confinement Fusion Experiments at Sandia National Laboratories. A physical understanding of the physics of wire-array z pinches is important in providing a future radiation source capable of driving high-yield fusion capsules. Modeling of wire-array implosions on the Z machine were performed using the 2-D radiation MHD code Alegra. These new calculations use more accurate initial conditions that are more representative of the experimental data, allowing us to model the implosion through stagnation, to avoid radiation collapse, and to generate a radiation pulse that compares well with data. Code predictions will be compared with tungsten & aluminum wire-array data from Z. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the U.S. Department of Energy under Contract No. DE-AC04- 94AL85000. a Ktech Corporation, 1300 Eubank Blvd. S.E., Albuquerque, NM 87123-3336