WorldWideScience

Sample records for ground-glass opacity ggo

  1. Deep neural network convolution (NNC) for three-class classification of diffuse lung disease opacities in high-resolution CT (HRCT): consolidation, ground-glass opacity (GGO), and normal opacity

    Science.gov (United States)

    Hashimoto, Noriaki; Suzuki, Kenji; Liu, Junchi; Hirano, Yasushi; MacMahon, Heber; Kido, Shoji

    2018-02-01

    Consolidation and ground-glass opacity (GGO) are two major types of opacities associated with diffuse lung diseases. Accurate detection and classification of such opacities are crucially important in the diagnosis of lung diseases, but the process is subjective, and suffers from interobserver variability. Our study purpose was to develop a deep neural network convolution (NNC) system for distinguishing among consolidation, GGO, and normal lung tissue in high-resolution CT (HRCT). We developed ensemble of two deep NNC models, each of which was composed of neural network regression (NNR) with an input layer, a convolution layer, a fully-connected hidden layer, and a fully-connected output layer followed by a thresholding layer. The output layer of each NNC provided a map for the likelihood of being each corresponding lung opacity of interest. The two NNC models in the ensemble were connected in a class-selection layer. We trained our NNC ensemble with pairs of input 2D axial slices and "teaching" probability maps for the corresponding lung opacity, which were obtained by combining three radiologists' annotations. We randomly selected 10 and 40 slices from HRCT scans of 172 patients for each class as a training and test set, respectively. Our NNC ensemble achieved an area under the receiver-operating-characteristic (ROC) curve (AUC) of 0.981 and 0.958 in distinction of consolidation and GGO, respectively, from normal opacity, yielding a classification accuracy of 93.3% among 3 classes. Thus, our deep-NNC-based system for classifying diffuse lung diseases achieved high accuracies for classification of consolidation, GGO, and normal opacity.

  2. Surgery for Pulmonary Multiple Ground Glass Opacities

    Directory of Open Access Journals (Sweden)

    Qun WANG

    2016-06-01

    Full Text Available The incidence of pulmonary ground glass opacity (GGO has been increasing in recent years, with a great number of patients having multiple GGOs. Unfortunately, the management of multiple GGOs is still controversial. Pulmonary GGO is a radiological term, consisting of different pathological types. Some of the GGOs are early-staged lung cancer. GGO is an indolent nodule, only a small proportion of GGOs change during observation, which does not influence the efficacy of surgery. . The timing of surgery for multiple GGOs mainly depends on the predominant nodule and surgery is recommended if the solid component of the predominant nodule >5 mm. Either lobectomy or sub-lobectomy is feasible. GGOs other than the predominant nodule can be left unresected. Multiple GGOs with high risk factors need mediastinal lymph node dissection or sampling.

  3. Preoperative Prediction of Ki-67 Labeling Index By Three-dimensional CT Image Parameters for Differential Diagnosis Of Ground-Glass Opacity (GGO.

    Directory of Open Access Journals (Sweden)

    Mingzheng Peng

    Full Text Available The aim of this study was to predict Ki-67 labeling index (LI preoperatively by three-dimensional (3D CT image parameters for pathologic assessment of GGO nodules. Diameter, total volume (TV, the maximum CT number (MAX, average CT number (AVG and standard deviation of CT number within the whole GGO nodule (STD were measured by 3D CT workstation. By detection of immunohistochemistry and Image Software Pro Plus 6.0, different Ki-67 LI were measured and statistically analyzed among preinvasive adenocarcinoma (PIA, minimally invasive adenocarcinoma (MIA and invasive adenocarcinoma (IAC. Receiver operating characteristic (ROC curve, Spearman correlation analysis and multiple linear regression analysis with cross-validation were performed to further research a quantitative correlation between Ki-67 labeling index and radiological parameters. Diameter, TV, MAX, AVG and STD increased along with PIA, MIA and IAC significantly and consecutively. In the multiple linear regression model by a stepwise way, we obtained an equation: prediction of Ki-67 LI=0.022*STD+0.001* TV+2.137 (R=0.595, R's square=0.354, p<0.001, which can predict Ki-67 LI as a proliferative marker preoperatively. Diameter, TV, MAX, AVG and STD could discriminate pathologic categories of GGO nodules significantly. Ki-67 LI of early lung adenocarcinoma presenting GGO can be predicted by radiologic parameters based on 3D CT for differential diagnosis.

  4. Ground-Glass Opacity Lung Nodules in the Era of Lung Cancer CT Screening

    DEFF Research Database (Denmark)

    Pedersen, Jesper Holst; Saghir, Zaigham; Wille, Mathilde Marie Winkler

    2016-01-01

    The advent of computed tomography screening for lung cancer will increase the incidence of ground-glass opacity (GGO) nodules detected and referred for diagnostic evaluation and management. GGO nodules remain a diagnostic challenge; therefore, a more systematic approach is necessary to ensure...... that will yield improvements in both diagnosis and treatment. The standard-of-care surgical treatment of early lung cancer is still minimally invasive lobectomy with systematic lymph node dissection. However, recent research has shown that some GGO lesions may be treated with sublobar resections; these findings......, the National Comprehensive Cancer Network, and the British Thoracic Society. In addition, we discuss the management and follow-up of GGO nodules in the light of experience from screening trials. Minimally invasive tissue biopsies and the marking of GGO nodules for surgery are new and rapidly developing fields...

  5. The relative frequencies of causes of widespread ground-glass opacity: A retrospective cohort

    International Nuclear Information System (INIS)

    Hewitt, Michael G.; Miller, Wallace T.; Reilly, Thomas J.; Simpson, Scott

    2014-01-01

    Highlights: • The most common cause of widespread ground-glass opacities is hydrostatic pulmonary edema. • Associated findings such as air-trapping and centrilobular nodules are highly specific for hypersensitivity pneumonitis. • The clinical setting (outpatient versus inpatient) will alter the order of the differential diagnosis. - Abstract: Purpose: The purpose of our study was to determine the relative frequencies of causes of widespread ground-glass opacity (GGO) in an unselected, consecutive patient population and to identify any associated imaging findings that can narrow or reorganize the differential. Materials and methods: The study was approved by the center's IRB and is HIPPA compliant. Cases with widespread GGO in the radiology report were identified by searching the Radiology Information System. Medical records and CT scan examinations were reviewed for the causes of widespread GGO. Associations between a less dominant imaging finding and a particular diagnosis were analyzed with the chi square test. Our study group consisted of 234 examinations with 124 women and 110 men and a mean age of 53.7 years. Results: A cause was established in 204 (87.2%) cases. Hydrostatic pulmonary edema was most common with 131 cases (56%). Interstitial lung diseases (ILD) were the next most common, most often hypersensitivity pneumonitis (HP) (n = 12, 5%) and connective tissue disease related ILD (n = 7, 3%). Infection accounted for 5% (12 cases). A few miscellaneous diseases accounted for 5 cases (2.1%). The combination of septal thickening and pleural effusions had a specificity of 0.91 for hydrostatic pulmonary edema (P < .001) while centrilobular nodules and air trapping had a specificity of 1.0 for HP. In 24 (10.2%) patients, increased opacification from expiration was incorrectly interpreted as representing widespread ground glass opacity. The relative frequency of disease dramatically changed according to the setting. In the inpatient setting, diffuse

  6. The relative frequencies of causes of widespread ground-glass opacity: A retrospective cohort

    Energy Technology Data Exchange (ETDEWEB)

    Hewitt, Michael G., E-mail: Mike_hewitt@me.com; Miller, Wallace T., E-mail: Wallace.miller@uphs.upenn.edu; Reilly, Thomas J., E-mail: thomasjreilly@comcast.net; Simpson, Scott, E-mail: Simpson80@gmail.com

    2014-10-15

    Highlights: • The most common cause of widespread ground-glass opacities is hydrostatic pulmonary edema. • Associated findings such as air-trapping and centrilobular nodules are highly specific for hypersensitivity pneumonitis. • The clinical setting (outpatient versus inpatient) will alter the order of the differential diagnosis. - Abstract: Purpose: The purpose of our study was to determine the relative frequencies of causes of widespread ground-glass opacity (GGO) in an unselected, consecutive patient population and to identify any associated imaging findings that can narrow or reorganize the differential. Materials and methods: The study was approved by the center's IRB and is HIPPA compliant. Cases with widespread GGO in the radiology report were identified by searching the Radiology Information System. Medical records and CT scan examinations were reviewed for the causes of widespread GGO. Associations between a less dominant imaging finding and a particular diagnosis were analyzed with the chi square test. Our study group consisted of 234 examinations with 124 women and 110 men and a mean age of 53.7 years. Results: A cause was established in 204 (87.2%) cases. Hydrostatic pulmonary edema was most common with 131 cases (56%). Interstitial lung diseases (ILD) were the next most common, most often hypersensitivity pneumonitis (HP) (n = 12, 5%) and connective tissue disease related ILD (n = 7, 3%). Infection accounted for 5% (12 cases). A few miscellaneous diseases accounted for 5 cases (2.1%). The combination of septal thickening and pleural effusions had a specificity of 0.91 for hydrostatic pulmonary edema (P < .001) while centrilobular nodules and air trapping had a specificity of 1.0 for HP. In 24 (10.2%) patients, increased opacification from expiration was incorrectly interpreted as representing widespread ground glass opacity. The relative frequency of disease dramatically changed according to the setting. In the inpatient setting, diffuse

  7. Percutaneous Radiofrequency Ablation of Lung Cancer Presenting as Ground-Glass Opacity

    Energy Technology Data Exchange (ETDEWEB)

    Iguchi, Toshihiro, E-mail: iguchi@ba2.so-net.ne.jp; Hiraki, Takao, E-mail: takaoh@tc4.so-net.ne.jp; Gobara, Hideo, E-mail: gobara@cc.okayama-u.ac.jp; Fujiwara, Hiroyasu, E-mail: hirofujiwar@gmail.com; Matsui, Yusuke, E-mail: wckyh140@yahoo.co.jp [Okayama University Medical School, Department of Radiology (Japan); Soh, Junichi, E-mail: soh-j@cc.okayama-u.ac.jp; Toyooka, Shinichi, E-mail: shintoyooka@gmail.com [Okayama University Medical School, Department of General Thoracic Surgery (Japan); Kiura, Katsuyuki, E-mail: kkiura@md.okayama-u.ac.jp [Okayama University Medical School, Department of Respiratory Medicine (Japan); Kanazawa, Susumu, E-mail: susumu@cc.okayama-u.ac.jp [Okayama University Medical School, Department of Radiology (Japan)

    2015-04-15

    PurposeWe retrospectively evaluated the outcomes of lung cancer patients presenting with ground-glass opacity (GGO) who received radiofrequency ablation (RFA).MethodsSixteen patients (5 men and 11 women; mean age, 72.6 years) with 17 lung cancer lesions showing GGO (mean long axis diameter, 1.6 cm) underwent a total of 20 percutaneous computed tomography (CT) fluoroscopy-guided RFA sessions, including three repeated sessions for local progression. Lung cancer with GGO was defined as a histologically confirmed malignant pulmonary lesion with a GGO component accounting for >50 % of the lesion on high-resolution CT. Procedure outcomes were evaluated.ResultsThere were no major complications. Pneumothorax occurred in 15 of 20 treatment sessions: 14 were asymptomatic, and 1 required chest tube placement but resolved satisfactorily within 48 h. Minor pulmonary hemorrhage occurred in two and mild pneumonitis in one. The median tumor follow-up period was 61.5 (range 6.1–96.6) months. The effectiveness rates of the primary and secondary techniques were 100 and 100 % at 1 year, 93.3 and 100 % at 2 years, and 78.3 and 92.3 % at 3 years, respectively. The median patient follow-up period was 65.6 (range 6.1–96.6) months. One patient died owing to recurrent other cancer 11.7 months after RFA, whereas the other 15 remained alive. Overall survival and disease-specific survival rates were 93.3 and 100 % at 1 year and 93.3 and 100 % at 5 years, respectively.ConclusionsRFA for lung cancer with GGO was safe and effective, and resulted in promising survival rates.

  8. Multidetector CT features of pulmonary focal ground-glass opacity: differences between benign and malignant

    Science.gov (United States)

    Fan, L; Liu, S-Y; Li, Q-C; Yu, H; Xiao, X-S

    2012-01-01

    Objective To evaluate different features between benign and malignant pulmonary focal ground-glass opacity (fGGO) on multidetector CT (MDCT). Methods 82 pathologically or clinically confirmed fGGOs were retrospectively analysed with regard to demographic data, lesion size and location, attenuation value and MDCT features including shape, margin, interface, internal characteristics and adjacent structure. Differences between benign and malignant fGGOs were analysed using a χ2 test, Fisher's exact test or Mann–Whitney U-test. Morphological characteristics were analysed by binary logistic regression analysis to estimate the likelihood of malignancy. Results There were 21 benign and 61 malignant lesions. No statistical differences were found between benign and malignant fGGOs in terms of demographic data, size, location and attenuation value. The frequency of lobulation (p=0.000), spiculation (p=0.008), spine-like process (p=0.004), well-defined but coarse interface (p=0.000), bronchus cut-off (p=0.003), other air-containing space (p=0.000), pleural indentation (p=0.000) and vascular convergence (p=0.006) was significantly higher in malignant fGGOs than that in benign fGGOs. Binary logistic regression analysis showed that lobulation, interface and pleural indentation were important indicators for malignant diagnosis of fGGO, with the corresponding odds ratios of 8.122, 3.139 and 9.076, respectively. In addition, a well-defined but coarse interface was the most important indicator of malignancy among all interface types. With all three important indicators considered, the diagnostic sensitivity, specificity and accuracy were 93.4%, 66.7% and 86.6%, respectively. Conclusion An fGGO with lobulation, a well-defined but coarse interface and pleural indentation gives a greater than average likelihood of being malignant. PMID:22128130

  9. Comparison of multi-slice CT findings between malignant focal pulmonary ground-glass opacity nodules and solid nodules of 3 cm or less

    International Nuclear Information System (INIS)

    Fan Li; Yu Hong; Liu Shiyuan; Li Qingchu; Jiang Tao; Xiao Xiangsheng

    2010-01-01

    Objective: To compare the MSCT findings of malignant focal pulmonary ground-glass opacity nodules (fGGO) and solid nodules of 3 cm or less, and try to find specific signs in fGGO. Methods: Clinical data (sex ratio, age), size of lesion and MSCT findings (shape, margin, interface, internal characteristics, adjacent structure) of 105 cases pathologically confirmed to have solid lung cancers and 48 cases with fGGO less than 3 cm were retrospectively analyzed. Differences were analyzed by using the Fisher exact test or Mann-Whitney U test. Results: The male and female ratio of solid lung cancer(60:45) were higher than that of fGGO (18:30, X 2 value 5.09, P 2 values were 11.48, 4.07, 29.70 and 22.38 respectively, P 2 values 1.00, 2.20, 0.00, 0.15, 4.43, 1.50, 0.00, P>0.05). Conclusions: Malignant fGGO and solid lung cancer manifest mostly similar MSCT features. The frequency of irregular shape, vacuole sign and air bronchograms was higher in fGGO than in solid lung cancer to some degree, but speculation is more infrequent in fGGO, which may be attribute to thepathological type and basis of tumor. (authors)

  10. Clinical Features of Ground Glass Opacity-Dominant Lung Cancer Exceeding 3.0 cm in the Whole Tumor Size.

    Science.gov (United States)

    Suzuki, Shigeki; Sakurai, Hiroyuki; Yotsukura, Masaya; Masai, Kyohei; Asakura, Keisuke; Nakagawa, Kazuo; Motoi, Noriko; Watanabe, Shun-Ichi

    2018-05-01

    Ground glass opacity (GGO)-dominant lung adenocarcinoma sized 3.0 cm or less in the whole tumor size is widely known to have an excellent prognosis and is regarded as early lung cancer. However, the characteristics and prognosis of lung cancer showing GGO exceeding 3.0 cm remains unclear. From 2002 through 2012, we reviewed 3,735 lung cancers that underwent complete resection at our institution. We identified 160 lung cancers (4.3%) showing GGO exceeding 3.0 cm on thin-section computed tomography and divided them into three types by the consolidation/tumor ratio (CTR) using cutoff values of 0.25 and 0.5. We compared the characteristics and prognosis among these types. Type A (CTR, 0 to ≤0.25), type B (CTR, >0.25 to ≤0.5), and type C (CTR, >0.5 to 3.0 cm can be considered to be in a group of patients with nodal-negative disease and an excellent prognosis. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  11. Loss of cellular viability in areas of ground-glass opacity on computed tomography images immediately after pulmonary radiofrequency ablation in rabbits

    International Nuclear Information System (INIS)

    Kuroki, Masaomi; Nakada, Hiroshi; Yamashita, Atsushi; Sawaguchi, Akira; Uchino, Noriko; Sato, Shinya; Asada, Yujiro; Tamura, Shozo; Asanuma, Taketoshi

    2012-01-01

    The purpose of this study was to determine cellular viability of lung parenchyma and neoplastic cells in areas of ground-glass opacity (GGO) on computed tomography (CT) images immediately after pulmonary radiofrequency ablation (RFA) in rabbits. A LeVeen RFA electrode was placed percutaneously into rabbit lungs with or without metastatic VX2 tumors. Five minutes later, seven isolated lungs were imaged by use of a multi-detector row CT scanner, and the images were compared with histological features. The cellular viability of the lung tissues was assessed by nicotinamide adenine dinucleotide hydrogen (NADH) staining in eight normal lungs and in three lungs with multiple metastatic tumors. All lung lesions appeared as bilayered structures with a central, dense, attenuated area and an outer area of GGO on CT images, and as three-layered structures on macroscopic and microscopic images 5 min after RFA. The GGO areas approximately corresponded to the outer two layers in macroscopic images that were exudative and congestive on microscopic images. Staining for NADH was significantly reduced in the GGO and densely attenuated areas with or without tumor tissue staining compared with the non-ablated area. Our results suggest that an area of GGO that appears on CT immediately after RFA can be effectively treated by RFA. (author)

  12. Imaging-guided thoracoscopic resection of a ground-glass opacity lesion in a hybrid operating room equipped with a robotic C-arm CT system.

    Science.gov (United States)

    Hsieh, Chen-Ping; Hsieh, Ming-Ju; Fang, Hsin-Yueh; Chao, Yin-Kai

    2017-05-01

    The intraoperative identification of small pulmonary nodules through video-assisted thoracoscopic surgery remains challenging. Although preoperative CT-guided nodule localization is commonly used to detect tumors during video-assisted thoracoscopic surgery (VATS), this approach carries inherent risks. We report the case of a patient with stage I lung cancer presenting as an area of ground-glass opacity (GGO) in the right upper pulmonary lobe. He successfully underwent a single-stage, CT-guided localization and removal of the pulmonary nodule within a hybrid operating room (OR) equipped with a robotic C-arm.

  13. Ground-glass opacity in lung metastasis from adenocarcinoma of the stomach: a case report

    International Nuclear Information System (INIS)

    Jung, Mi Ran; Kim, Jeong Kon; Lee, Jin Seong; Song, Koun Sik; Lim, Tae Hwan

    2000-01-01

    Ground-glass opacity is a frequent but nonspecific finding seen on high-resolution CT scans of lung parenchyma. Histologically, this appearance is observed when thickening of the alveolar wall and septal interstitium is minimal or the alveolar lumen is partially filled with fluid, macrophage, neutrophils, or amorphous material. It has been shown that ground-glass opacity may be caused not only by an active inflammatory process but also by fibrotic processes. When a focal area of ground-glass opacity persists or increases in size, the possibility of neoplasm-bronchioloalveolar carcinoma or adenoma, or lymphoma, for example, should be considered. Diffuse nonsegmental ground-glass opacity in both lung fields was incidentally found on follow up abdominal CT in a stomach cancer patient and signet-ring cell-type metastatic lung cancer was confirmed by transbronchial lung biopsy. We report a case of diffuse ground-glass opacity seen in metastatic lung cancer from adenocarcinoma of the stomach. (author)

  14. Comparison of chest radiography, chest digital tomosynthesis and low dose MDCT to detect small ground-glass opacity nodules: an anthropomorphic chest phantom study

    International Nuclear Information System (INIS)

    Doo, Kyung Won; Kang, Eun-Young; Yong, Hwan Seok; Ham, Soo-Youn; Lee, Ki Yeol; Choo, Ji Yung

    2014-01-01

    The purpose of this study was to evaluate the diagnostic performance of chest radiography (CXR), chest digital tomosynthesis (DT) and low dose multidetector computed tomography (LDCT) for the detection of small pulmonary ground-glass opacity (GGO) nodules, using an anthropomorphic chest phantom. Artificial pulmonary nodules were placed in a phantom and a total of 40 samples of different nodule settings underwent CXR, DT and LDCT. The images were randomly read by three experienced chest radiologists. Free-response receiver-operating characteristics (FROC) were used. The figures of merit for the FROC curves averaged for the three observers were 0.41, 0.37 and 0.76 for CXR, DT and LDCT, respectively. FROC analyses revealed significantly better performance of LDCT over CXR or DT for the detection of GGO nodules (P < 0.05). The difference in detectability between CXR and DT was not statistically significant (P = 0.73). The diagnostic performance of DT for the detection of pulmonary small GGO nodules was not significantly different from that of CXR, but LDCT performed significantly better than both CXR and DT. DT is not a suitable alternative to CT for small GGO nodule detection, and LDCT remains the method of choice for this purpose. (orig.)

  15. Comparison of chest radiography, chest digital tomosynthesis and low dose MDCT to detect small ground-glass opacity nodules: an anthropomorphic chest phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Doo, Kyung Won; Kang, Eun-Young; Yong, Hwan Seok [Korea University Guro Hospital, Korea University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Ham, Soo-Youn [Korea University Anam Hospital, Korea University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Lee, Ki Yeol; Choo, Ji Yung [Korea University Ansan Hospital, Korea University College of Medicine, Department of Radiology, Ansan (Korea, Republic of)

    2014-12-15

    The purpose of this study was to evaluate the diagnostic performance of chest radiography (CXR), chest digital tomosynthesis (DT) and low dose multidetector computed tomography (LDCT) for the detection of small pulmonary ground-glass opacity (GGO) nodules, using an anthropomorphic chest phantom. Artificial pulmonary nodules were placed in a phantom and a total of 40 samples of different nodule settings underwent CXR, DT and LDCT. The images were randomly read by three experienced chest radiologists. Free-response receiver-operating characteristics (FROC) were used. The figures of merit for the FROC curves averaged for the three observers were 0.41, 0.37 and 0.76 for CXR, DT and LDCT, respectively. FROC analyses revealed significantly better performance of LDCT over CXR or DT for the detection of GGO nodules (P < 0.05). The difference in detectability between CXR and DT was not statistically significant (P = 0.73). The diagnostic performance of DT for the detection of pulmonary small GGO nodules was not significantly different from that of CXR, but LDCT performed significantly better than both CXR and DT. DT is not a suitable alternative to CT for small GGO nodule detection, and LDCT remains the method of choice for this purpose. (orig.)

  16. Ground-glass opacity at high resolution CT: an approach for differential diagnosis

    International Nuclear Information System (INIS)

    Spina, Juan C.; Rogondino, Jose; Vidales, Valeria; Rolnik, Maria C.; Montanari, Mariano; Salazar, Santiago N.

    2004-01-01

    Purpose: To evaluate the Ground-Glass Opacity in high resolution computed tomography (HRCT) with its underlying abnormality and anatomic distribution and its correlation with different etiologies. Methods: A 38 patients series, (32 men, 16 women, mean age 54,6 years, range 20-28) was retrospectively analyzed. They were evaluated with high resolution computed tomography, 2 mm thick sections and 10 mm of interval. Contrast intravenous iodinated contrast (no-ionic) was injected in 11 patients. The final diagnosis was made with sputum analysis, bronchioalveolar lavage, trans bronchial biopsy and open lung biopsy. Results: The differential diagnosis of ground glass opacity is based on analyzing their anatomic resolution and the underlying pathology in the lung parenchyma. Centrilobular distribution indicated early air-spaces pathology produced in our series by 21 infections, 4 pulmonary hemorrhages, 1 hypersensitivity pneumonitis and 1 descamative interstitial pneumonitis. Panlobular distribution, alveolar proteinosis (1 case) sarcoidosis (1 case) drug toxicity 1 case and one case of pneumocystis carinii. Peripherical distribution typical of early idiopathic fibrosis (1). Bronchiolitis obliterans with organizing pneumonia (1). Structural alterations of the lung parenchyma with bronchiectasias was seen in 16 cases, cystic lesions in 3 cases, sub pleural linear opacities 4 cases, peribronchovascular interstitial thickening or nodularity and emphysema in 10 cases. Conclusion: HRCT is useful to evaluate ground glass opacities pattern with the anatomic distribution and the underlying structural pathology. These findings under some clinical circumstances can suggest a specific diagnosis in most cases, indicating a potentially treatable disease. (author)

  17. CT characteristics and pathological implications of early stage (T1N0M0) lung adenocarcinoma with pure ground-glass opacity

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Xin; Zhao, Shao-hong; Wu, Jian; Wu, Chong-chong; Chang, Rui-ping; Ju, Hai-yue [Chinese PLA General Hospital, Department of Radiology, Beijing (China); Gao, Jie; Wang, Dian-jun [Chinese PLA General Hospital, Department of Pathology, Beijing (China)

    2015-09-15

    To analyze the CT characteristics and pathological classification of early lung adenocarcinoma (T1N0M0) with pure ground-glass opacity (pGGO). Ninety-four lesions with pGGO on CT in 88 patients with T1N0M0 lung adenocarcinoma were selected from January 2010 to December 2012. All lesions were confirmed by pathology. CT appearances were analyzed including lesion location, size, density, uniformity, shape, margin, tumour-lung interface, internal and surrounding malignant signs. Lesion size and density were compared using analysis of variance, lesion size also assessed using ROC curves. Gender of patients, lesion location and CT appearances were compared using χ2-test. There were no significant differences in gender, lesion location and density with histological invasiveness (P > 0.05). The ROC curve showed that the possibility of invasive lesion was 88.73 % when diameter of lesion was more than 10.5 mm. There was a significant difference between lesion uniformity and histological invasiveness (P = 0.01). There were significant differences in margin, tumour-lung interface, air bronchogram with histological invasiveness (P = 0.02,P = 0.00,P = 0.048). The correlation index of lesion size and uniformity was r = 0.45 (P = 0.00). The lesion size and uniformity, tumour-lung interface and the air bronchogram can help predict invasive extent of early stage lung adenocarcinoma with pGGO. (orig.)

  18. Ground-glass opacity in diffuse lung diseases: high-resolution computed tomography-pathology correlation

    International Nuclear Information System (INIS)

    Santos, Maria Lucia de Oliveira; Vianna, Alberto Domingues; Marchiori, Edson; Souza Junior, Arthur Soares; Moraes, Heleno Pinto de

    2003-01-01

    Ground-glass opacity is a finding frequently seen in high-resolution computed tomography examinations of the chest and is characterized by hazy increased attenuation of lung, however without blurring of bronchial and vascular margins. Due to its un specificity, association with other radiological, clinical and pathological findings must be considered for an accurate diagnostic interpretation. In this paper were reviewed 62 computed tomography examinations of patients with diffuse pulmonary diseases of 14 different etiologies in which ground-glass opacity was the only or the most remarkable finding, and correlated this findings with pathology abnormalities seen on specimens obtained from biopsies or necropsies. In pneumocystosis, ground-glass opacities correlated histologically with alveolar occupation by a foaming material containing parasites, in bronchiole alveolar cell carcinoma with thickening of the alveolar septa and occupation of the lumen by mucus and tumoral cells, in paracoccidioidomycosis with thickening of the alveolar septa, areas of fibrosis and alveolar bronchopneumonia exudate, in sarcoidosis with fibrosis or clustering of granulomas and in idiopathic pulmonary fibrosis with alveolar septa thickening due to fibrosis. Alveolar occupation by blood was found in cases of leptospirosis, idiopathic hemo siderosis, metastatic kidney tumor and invasive aspergillosis whereas oily vacuole were seen in lipoid pneumonia, proteinaceous and lipo proteinaceous material in silico proteinosis and pulmonary alveolar proteinosis, and edematous fluid in cardiac failure. (author)

  19. Evaluation of the extent of ground-glass opacity on high-resolution CT in patients with interstitial pneumonia associated with systemic sclerosis: Comparison between quantitative and qualitative analysis

    International Nuclear Information System (INIS)

    Yabuuchi, H.; Matsuo, Y.; Tsukamoto, H.; Horiuchi, T.; Sunami, S.; Kamitani, T.; Jinnouchi, M.; Nagao, M.; Akashi, K.; Honda, H.

    2014-01-01

    Aim: To verify whether quantitative analysis of the extent of ground-glass opacity (GGO) on high-resolution computed tomography (HRCT) could show a stronger correlation with the therapeutic response of interstitial pneumonia (IP) associated with systemic sclerosis (SSc) compared with qualitative analysis. Materials and methods: Seventeen patients with IP associated with SSc received autologous peripheral blood stem cell transplantation (auto-PBSCT) and were followed up using HRCT and pulmonary function tests. Two thoracic radiologists assessed the extent of GGO on HRCT using a workstation. Therapeutic effect was assessed using the change of vital capacity (VC) and diffusing capacity of the lung for carbon monoxide (DLco) before and 12 months after PBSCT. Interobserver agreement was assessed using Spearman's rank correlation coefficient and the Bland–Altman method. Correlation with the therapeutic response between quantitative and qualitative analysis was assessed with Pearson's correlation coefficients. Results: Spearman's rank correlation coefficient showed good agreement, but Bland–Altman plots showed that proportional error could be suspected. Quantitative analysis showed stronger correlation than the qualitative analysis based on the relationships between the change in extent of GGO and VC, and change in extent of GGO and DLco. Conclusion: Quantitative analysis of the change in extent of GGO showed stronger correlation with the therapeutic response of IP with SSc after auto-PBSCT than with the qualitative analysis. - Highlights: • Quantitative analysis of GGO in IP showed strong correlation with therapeutic effect. • Qualitative analysis might be limited by interobserver variance. • Other parameters including reticular opacities remain in a future investigation

  20. Ground-glass opacity: High-resolution computed tomography and 64-multi-slice computed tomography findings comparison

    International Nuclear Information System (INIS)

    Sergiacomi, Gianluigi; Ciccio, Carmelo; Boi, Luca; Velari, Luca; Crusco, Sonia; Orlacchio, Antonio; Simonetti, Giovanni

    2010-01-01

    Objective: Comparative evaluation of ground-glass opacity using conventional high-resolution computed tomography technique and volumetric computed tomography by 64-row multi-slice scanner, verifying advantage of volumetric acquisition and post-processing technique allowed by 64-row CT scanner. Methods: Thirty-four patients, in which was assessed ground-glass opacity pattern by previous high-resolution computed tomography during a clinical-radiological follow-up for their lung disease, were studied by means of 64-row multi-slice computed tomography. Comparative evaluation of image quality was done by both CT modalities. Results: It was reported good inter-observer agreement (k value 0.78-0.90) in detection of ground-glass opacity with high-resolution computed tomography technique and volumetric Computed Tomography acquisition with moderate increasing of intra-observer agreement (k value 0.46) using volumetric computed tomography than high-resolution computed tomography. Conclusions: In our experience, volumetric computed tomography with 64-row scanner shows good accuracy in detection of ground-glass opacity, providing a better spatial and temporal resolution and advanced post-processing technique than high-resolution computed tomography.

  1. Investigation of optimal display size for detecting ground-glass opacity on high resolution computed tomography using a new digital contrast-detail phantom

    International Nuclear Information System (INIS)

    Yamaguchi, Michihiro; Fujita, Hideki; Bessho, Yuichi; Inoue, Tatsuro; Asai, Yoshiyuki; Murase, Kenya

    2011-01-01

    The purpose of this study was to clarify the relationship between display sizes of high resolution computed tomography (HRCT) images for detecting ground-glass opacity (GGO) and observer performance using a digital contrast-detail (d-CD) phantom. A structure of the d-CD phantom was determined on the basis of the actual images of GGOs and background noises of 22 patients who were diagnosed as GGO by chest HRCT. The d-CD phantom has a 512 × 512 matrix in size and has total of 100 holes: the diameter of these holes increases stepwise from 2 to 20 pixels with 2 pixels interval in a vertical direction and the CT value varies stepwise from 2 to 200 HU in a horizontal direction. The observer performance study was carried out for three different display sizes (30 cm × 30 cm as an enlarged size, 13 cm × 13 cm as an original size, and 7 cm × 7 cm as a reduced size) using a 2-megapixels LCD monitor, and it was analyzed using Friedman and Wilcoxon statistical tests. As a result, the observer performance for the original display and the reduced display sizes was superior to that for the enlarged size (P = 0.006 and 0.037 for the original display and the reduced display sizes, respectively), whereas there was no significant difference between the original display and reduced display sizes (P = 0.77). The d-CD phantom enables a short-term evaluation of observer performance and is useful in analyzing relationship between display size and observer performance.

  2. TU-H-CAMPUS-JeP2-03: Machine-Learning-Based Delineation Framework of GTV Regions of Solid and Ground Glass Opacity Lung Tumors at Datasets of Planning CT and PET/CT Images

    Energy Technology Data Exchange (ETDEWEB)

    Ikushima, K; Arimura, H; Jin, Z; Yabuuchi, H; Sasaki, T; Honda, H; Sasaki, M [Kyushu University, Fukuoka, Fukuoka (Japan); Kuwazuru, J [Saiseikai Fukuoka General Hospital, Fukuoka, Fukuoka (Japan); Shioyama, Y [Saga Heavy Ion Medical Accelerator in Tosu, Tosu, Saga (Japan)

    2016-06-15

    Purpose: In radiation treatment planning, delineation of gross tumor volume (GTV) is very important, because the GTVs affect the accuracies of radiation therapy procedure. To assist radiation oncologists in the delineation of GTV regions while treatment planning for lung cancer, we have proposed a machine-learning-based delineation framework of GTV regions of solid and ground glass opacity (GGO) lung tumors following by optimum contour selection (OCS) method. Methods: Our basic idea was to feed voxel-based image features around GTV contours determined by radiation oncologists into a machine learning classifier in the training step, after which the classifier produced the degree of GTV for each voxel in the testing step. Ten data sets of planning CT and PET/CT images were selected for this study. The support vector machine (SVM), which learned voxel-based features which include voxel value and magnitudes of image gradient vector that obtained from each voxel in the planning CT and PET/CT images, extracted initial GTV regions. The final GTV regions were determined using the OCS method that was able to select a global optimum object contour based on multiple active delineations with a level set method around the GTV. To evaluate the results of proposed framework for ten cases (solid:6, GGO:4), we used the three-dimensional Dice similarity coefficient (DSC), which denoted the degree of region similarity between the GTVs delineated by radiation oncologists and the proposed framework. Results: The proposed method achieved an average three-dimensional DSC of 0.81 for ten lung cancer patients, while a standardized uptake value-based method segmented GTV regions with the DSC of 0.43. The average DSCs for solid and GGO were 0.84 and 0.76, respectively, obtained by the proposed framework. Conclusion: The proposed framework with the support vector machine may be useful for assisting radiation oncologists in delineating solid and GGO lung tumors.

  3. Advances in intelligent diagnosis methods for pulmonary ground-glass opacity nodules.

    Science.gov (United States)

    Yang, Jing; Wang, Hailin; Geng, Chen; Dai, Yakang; Ji, Jiansong

    2018-02-07

    Pulmonary nodule is one of the important lesions of lung cancer, mainly divided into two categories of solid nodules and ground glass nodules. The improvement of diagnosis of lung cancer has significant clinical significance, which could be realized by machine learning techniques. At present, there have been a lot of researches focusing on solid nodules. But the research on ground glass nodules started late, and lacked research results. This paper summarizes the research progress of the method of intelligent diagnosis for pulmonary nodules since 2014. It is described in details from four aspects: nodular signs, data analysis methods, prediction models and system evaluation. This paper aims to provide the research material for researchers of the clinical diagnosis and intelligent analysis of lung cancer, and further improve the precision of pulmonary ground glass nodule diagnosis.

  4. Thin-section computed tomography–histopathologic comparisons of pulmonary focal interstitial fibrosis, atypical adenomatous hyperplasia, adenocarcinoma in situ, and minimally invasive adenocarcinoma with pure ground-glass opacity

    Energy Technology Data Exchange (ETDEWEB)

    Si, Ming-Jue, E-mail: smjsh@hotmail.com [Department of Radiology, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, No. 280, Mohe Road, Shanghai 201999 (China); Tao, Xiao-Feng, E-mail: taoxiaofeng1963@hotmail.com [Department of Radiology, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, No. 280, Mohe Road, Shanghai 201999 (China); Du, Guang-Ye, E-mail: 715376158@qq.com [Department of Pathology, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, No. 280, Mohe Road, Shanghai 201999 (China); Cai, Ling-Ling, E-mail: caill_00@163.com [Department of Radiology, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, No. 280, Mohe Road, Shanghai 201999 (China); Han, Hong-Xiu, E-mail: hanhongxiu@hotmail.com [Department of Pathology, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, No. 280, Mohe Road, Shanghai 201999 (China); Liang, Xi-Zi, E-mail: liangxizish@hotmail.com [Department of Pathology, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, No. 280, Mohe Road, Shanghai 201999 (China); Zhao, Jiang-Min, E-mail: zhaojiangmin1962@hotmail.com [Department of Radiology, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, No. 280, Mohe Road, Shanghai 201999 (China)

    2016-10-15

    Objective: To retrospectively compare focal interstitial fibrosis (FIF), atypical adenomatous hyperplasia (AAH), adenocarcinoma in situ (AIS), and minimally invasive adenocarcinoma (MIA) with pure ground-glass opacity (GGO) using thin-section computed tomography (CT). Materials and methods: Sixty pathologically confirmed cases were reviewed including 7 cases of FIF, 17 of AAH, 23of AIS, and 13 of MIA. All nodules kept pure ground glass appearances before surgical resection and their last time of thin-section CT imaging data before operation were collected. Differences of patient demographics and CT features were compared among these four types of lesions. Results: FIF occurred more frequently in males and smokers while the others occurred more frequently in female nonsmokers. Nodule size was significant larger in MIA (P < 0.001, cut-off value = 7.5 mm). Nodule shape (P = 0.045), margin characteristics (P < 0.001), the presence of pleural indentation (P = 0.032), and vascular ingress (P < 0.001) were significant factors that differentiated the 4 groups. A concave margin was only demonstrated in a high proportion of FIF at 85.7% (P = 0.002). There were no significant differences (all P > 0.05) in age, malignant history, attenuation value, location, and presence of bubble-like lucency. Conclusion: A nodule size >7.5 mm increases the possibility of MIA. A concave margin could be useful for differentiation of FIF from the other malignant or pre-malignant GGO nodules. The presence of spiculation or pleural indentation may preclude the diagnosis of AAH.

  5. Clinical, pathological, and radiological characteristics of solitary ground-glass opacity lung nodules on high-resolution computed tomography

    Directory of Open Access Journals (Sweden)

    Qiu ZX

    2016-09-01

    Full Text Available Zhi-Xin Qiu,1 Yue Cheng,1 Dan Liu,1 Wei-Ya Wang,2 Xia Wu,2 Wei-Lu Wu,2 Wei-Min Li1,2 1Department of Respiratory Medicine, 2Department of Pathology, West China Hospital, Sichuan University, Chengdu, People’s Republic of China Background: Lung nodules are being detected at an increasing rate year by year with high-resolution computed tomography (HRCT being widely used. Ground-glass opacity nodule is one of the special types of pulmonary nodules that is confirmed to be closely associated with early stage of lung cancer. Very little is known about solitary ground-glass opacity nodules (SGGNs. In this study, we analyzed the clinical, pathological, and radiological characteristics of SGGNs on HRCT.Methods: A total of 95 resected SGGNs were evaluated with HRCT scan. The clinical, pathological, and radiological characteristics of these cases were analyzed.Results: Eighty-one adenocarcinoma and 14 benign nodules were observed. The nodules included 12 (15% adenocarcinoma in situ (AIS, 14 (17% minimally invasive adenocarcinoma (MIA, and 55 (68% invasive adenocarcinoma (IA. No patients with recurrence till date have been identified. The positive expression rates of anaplastic lymphoma kinase and ROS-1 (proto-oncogene tyrosine-protein kinase ROS were only 2.5% and 8.6%, respectively. The specificity and accuracy of HRCT of invasive lung adenocarcinoma were 85.2% and 87.4%. The standard uptake values of only two patients determined by 18F-FDG positron emission tomography/computed tomography (PET/CT were above 2.5. The size, density, shape, and pleural tag of nodules were significant factors that differentiated IA from AIS and MIA. Moreover, the size, shape, margin, pleural tag, vascular cluster, bubble-like sign, and air bronchogram of nodules were significant determinants for mixed ground-glass opacity nodules (all P<0.05.Conclusion: We analyzed the clinical, pathological, and radiological characteristics of SGGNs on HRCT and found that the size, density

  6. The Clinical and Molecular Characteristics of Adenocarcinoma Presented 
by Multi-focal GGO

    Directory of Open Access Journals (Sweden)

    Yang SONG

    2018-03-01

    Full Text Available Due to emphasis on early screening for lung cancer, the detection rate of multiple ground glass opacities (GGOs on computed tomography (CT image increases in recent years, and research on multifocal adenocarcinomas presented by GGOs has been thriving. It is more common in women and non-smokers and has excellent prognosis both in patients with natural history and after surgery. These clinical features suggest that it is likely to be a distinct disease entity. From the perspective of molecular genetics, lesions in the same individual are likely to have distinct clonal features. Therefore, genetic heterogeneity is the most prominent feature of multifocal pulmonary adenocarcinomas with GGOs. The genetic heterogeneity is expected to assist the diagnosis of multifocal pulmonary adenocarcinoma and intrapulmonary metastasis, and also suggests that genetic testing of the GGO lesions is of great therapeutic significance. Some GGO lesions may harvest the similar clonal feature, which provide new evidence for the theory of spread through air spaces (STAS.

  7. [The Clinical and Molecular Characteristics of Adenocarcinoma Presented 
by Multi-focal GGO].

    Science.gov (United States)

    Song, Yang; Liang, Naixin; Li, Shanqing

    2018-03-20

    Due to emphasis on early screening for lung cancer, the detection rate of multiple ground glass opacities (GGOs) on computed tomography (CT) image increases in recent years, and research on multifocal adenocarcinomas presented by GGOs has been thriving. It is more common in women and non-smokers and has excellent prognosis both in patients with natural history and after surgery. These clinical features suggest that it is likely to be a distinct disease entity. From the perspective of molecular genetics, lesions in the same individual are likely to have distinct clonal features. Therefore, genetic heterogeneity is the most prominent feature of multifocal pulmonary adenocarcinomas with GGOs. The genetic heterogeneity is expected to assist the diagnosis of multifocal pulmonary adenocarcinoma and intrapulmonary metastasis, and also suggests that genetic testing of the GGO lesions is of great therapeutic significance. Some GGO lesions may harvest the similar clonal feature, which provide new evidence for the theory of spread through air spaces (STAS).
.

  8. Ground-glass opacity in diffuse lung diseases: high-resolution computed tomography-pathology correlation; Opacidades em vidro fosco nas doencas pulmonares difusas: correlacao da tomografia computadorizada de alta resolucao com a anatomopatologia

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Maria Lucia de Oliveira; Vianna, Alberto Domingues; Marchiori, Edson [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Radiologia; Souza Junior, Arthur Soares [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Disciplina de Radiologia; Moraes, Heleno Pinto de [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Patologia]. E-mail: edmarchiori@zipmail.com.br

    2003-12-01

    Ground-glass opacity is a finding frequently seen in high-resolution computed tomography examinations of the chest and is characterized by hazy increased attenuation of lung, however without blurring of bronchial and vascular margins. Due to its un specificity, association with other radiological, clinical and pathological findings must be considered for an accurate diagnostic interpretation. In this paper were reviewed 62 computed tomography examinations of patients with diffuse pulmonary diseases of 14 different etiologies in which ground-glass opacity was the only or the most remarkable finding, and correlated this findings with pathology abnormalities seen on specimens obtained from biopsies or necropsies. In pneumocystosis, ground-glass opacities correlated histologically with alveolar occupation by a foaming material containing parasites, in bronchiole alveolar cell carcinoma with thickening of the alveolar septa and occupation of the lumen by mucus and tumoral cells, in paracoccidioidomycosis with thickening of the alveolar septa, areas of fibrosis and alveolar bronchopneumonia exudate, in sarcoidosis with fibrosis or clustering of granulomas and in idiopathic pulmonary fibrosis with alveolar septa thickening due to fibrosis. Alveolar occupation by blood was found in cases of leptospirosis, idiopathic hemo siderosis, metastatic kidney tumor and invasive aspergillosis whereas oily vacuole were seen in lipoid pneumonia, proteinaceous and lipo proteinaceous material in silico proteinosis and pulmonary alveolar proteinosis, and edematous fluid in cardiac failure. (author)

  9. The diagnostic value of grand glass opacity on HRCT of the lung

    International Nuclear Information System (INIS)

    He Wen; Ma Daqing; Feng Jie; He Qing; Hu Zhihai

    2001-01-01

    Objective: To determine the value of ground glass opacity (GGO) as a diagnostic sign of HRCT by means of analyzing a group of 34 cases retrospectively. Methods: Thirty-four cases of lung diseases, in which GGO were found on HRCT, were included in this study. The diagnosis was proven by lung biopsy in 7 cases, by endoscopy and micro-phytology in 7 cases and clinically in 20 cases. The distribution, extent and associated findings of GGO were studied in correlation with the final diagnosis retrospectively. Results: In these 34 cases, 20 cases were interstitial diseases, in which GGO distributed peripherally with an ill-defined margin. In 8 cases of parenchymal diseases, the lesion had a lobar or segmental distribution with a relatively well-defined margin. In 6 cases with chronic obstructive airway diseases, the GGO located centrally or peripherally, and most of them had a mosaic pattern with dilatation of vessels in the center of GGO. Conclusion: GGO is a nonspecific finding on chest HRCT, and may be seen in various diseases including interstitial and parenchymal diseases, or in diseases causing increased capillary blood volume. To analyze the morphological characteristics of GGO and associated CT findings correlating with clinical history can narrow the range of diagnostic possibilities and lead to a correct diagnosis

  10. Predictive value of mutant p53 expression index obtained from nonenhanced computed tomography measurements for assessing invasiveness of ground-glass opacity nodules

    Directory of Open Access Journals (Sweden)

    Wang W

    2016-03-01

    Full Text Available Wei Wang,1 Jian Li,2 Ransheng Liu,1 Aixu Zhang,1 Zhiyong Yuan1 1Department of Radiation Oncology, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center of Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin, People’s Republic of China; 2Department of Radiology, Tianjin Hospital, Tianjin, People’s Republic of China Purpose: To predict p53 expression index (p53-EI based on measurements from computed tomography (CT for preoperatively assessing pathologies of nodular ground-glass opacities (nGGOs. Methods: Information of 176 cases with nGGOs on high-resolution CT that were pathologically confirmed adenocarcinoma was collected. Diameters, total volumes (TVs, maximum (MAX, average (AVG, and standard deviation (STD of CT attenuations within nGGOs were measured. p53-EI was evaluated through immunohistochemistry with Image-Pro Plus 6.0. A multiple linear stepwise regression model was established to calculate p53-EI prediction from CT measurements. Receiver-operating characteristic curve analysis was performed to compare the diagnostic performance of variables in differentiating preinvasive adenocarcinoma (PIA, minimally invasive adenocarcinoma (MIA, and invasive adenocarcinoma (IAC. Results: Diameters, TVs, MAX, AVG, and STD showed significant differences among PIAs, MIAs, and IACs (all P-values <0.001, with only MAX being incapable to differentiate MIAs from IACs (P=0.106. The mean p53-EIs of PIAs, MIAs, and IACs were 3.4±2.0, 7.2±1.9, and 9.8±2.7, with significant intergroup differences (all P-values <0.001. An equation was established by multiple linear regression as: p53-EI prediction =0.001* TVs +0.012* AVG +0.022* STD +9.345, through which p53-EI predictions were calculated to be 4.4%±1.0%, 6.8%±1.3%, and 8.5%±1.4% for PIAs, MIAs, and IACs (Kruskal–Wallis test P<0.001; Tamhane’s T2 test: PIA vs MIA P<0.001, MIA vs IAC P<0.001, respectively. Although not significant, p53-EI prediction

  11. Effect of reconstruction algorithm on image quality and identification of ground-glass opacities and partly solid nodules on low-dose thin-section CT: Experimental study using chest phantom

    International Nuclear Information System (INIS)

    Koyama, Hisanobu; Ohno, Yoshiharu; Kono, Atsushi A.; Kusaka, Akiko; Konishi, Minoru; Yoshii, Masaru; Sugimura, Kazuro

    2010-01-01

    Purpose: The purpose of this study was to assess the influence of reconstruction algorithm on identification and image quality of ground-glass opacities (GGOs) and partly solid nodules on low-dose thin-section CT. Materials and methods: A chest CT phantom including simulated GGOs and partly solid nodules was scanned with five different tube currents and reconstructed by using standard (A) and newly developed (B) high-resolution reconstruction algorithms, followed by visually assessment of identification and image quality of GGOs and partly solid nodules by two chest radiologists. Inter-observer agreement, ROC analysis and ANOVA were performed to compare identification and image quality of each data set with those of the standard reference. The standard reference used 120 mA s in conjunction with reconstruction algorithm A. Results: Kappa values (κ) of overall identification and image qualities were substantial or almost perfect (0.60 < κ). Assessment of identification showed that area under the curve of 25 mA reconstructed with reconstruction algorithm A was significantly lower than that of standard reference (p < 0.05), while assessment of image quality indicated that 50 mA s reconstructed with reconstruction algorithm A and 25 mA s reconstructed with both reconstruction algorithms were significantly lower than standard reference (p < 0.05). Conclusion: Reconstruction algorithm may be an important factor for identification and image quality of ground-glass opacities and partly solid nodules on low-dose CT examination.

  12. Opacity

    CERN Document Server

    Huebner, Walter F

    2014-01-01

    The interaction of radiation with matter is a fundamental process in the universe; in particular, the absorption and scattering of radiation by matter (the opacity) govern the formation, evolution, and structure of stars and planets.  But opacity is also important in many terrestrial applications in which radiation is the dominant means of energy transfer, such as controlled nuclear-fusion, laser ablation, atmospheric entry and reentry, and the "greenhouse" effect.  This book covers all aspects of opacity and equations of state for plasmas, gases, vapors, and dust and emphasizes the continuous transformation of phases and molecular compositions with changing density and temperature under conditions of local thermodynamic equilibrium (LTE) while preserving the basic abundances of the chemical elements in a mixture.

  13. Automatic recognition of 3D GGO CT imaging signs through the fusion of hybrid resampling and layer-wise fine-tuning CNNs.

    Science.gov (United States)

    Han, Guanghui; Liu, Xiabi; Zheng, Guangyuan; Wang, Murong; Huang, Shan

    2018-06-06

    Ground-glass opacity (GGO) is a common CT imaging sign on high-resolution CT, which means the lesion is more likely to be malignant compared to common solid lung nodules. The automatic recognition of GGO CT imaging signs is of great importance for early diagnosis and possible cure of lung cancers. The present GGO recognition methods employ traditional low-level features and system performance improves slowly. Considering the high-performance of CNN model in computer vision field, we proposed an automatic recognition method of 3D GGO CT imaging signs through the fusion of hybrid resampling and layer-wise fine-tuning CNN models in this paper. Our hybrid resampling is performed on multi-views and multi-receptive fields, which reduces the risk of missing small or large GGOs by adopting representative sampling panels and processing GGOs with multiple scales simultaneously. The layer-wise fine-tuning strategy has the ability to obtain the optimal fine-tuning model. Multi-CNN models fusion strategy obtains better performance than any single trained model. We evaluated our method on the GGO nodule samples in publicly available LIDC-IDRI dataset of chest CT scans. The experimental results show that our method yields excellent results with 96.64% sensitivity, 71.43% specificity, and 0.83 F1 score. Our method is a promising approach to apply deep learning method to computer-aided analysis of specific CT imaging signs with insufficient labeled images. Graphical abstract We proposed an automatic recognition method of 3D GGO CT imaging signs through the fusion of hybrid resampling and layer-wise fine-tuning CNN models in this paper. Our hybrid resampling reduces the risk of missing small or large GGOs by adopting representative sampling panels and processing GGOs with multiple scales simultaneously. The layer-wise fine-tuning strategy has ability to obtain the optimal fine-tuning model. Our method is a promising approach to apply deep learning method to computer-aided analysis

  14. Pure ground glass nodular adenocarcinomas: Are preoperative positron emission tomography/computed tomography and brain magnetic resonance imaging useful or necessary?

    Science.gov (United States)

    Cho, Hyoun; Lee, Ho Yun; Kim, Jhingook; Kim, Hong Kwan; Choi, Joon Young; Um, Sang-Won; Lee, Kyung Soo

    2015-09-01

    The utility of (18)F-Fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) scanning and brain magnetic resonance imaging (MRI) as a staging workup for lung adenocarcinoma manifesting as pure ground glass opacity (GGO) is unknown. The purpose of this study was to determine the utility of these 2 tests for preoperative staging of pure GGO nodular lung adenocarcinoma. The study included 164 patients (male:female, 73:91; mean age, 62 years) with pure GGO nodular lung adenocarcinoma who underwent PET/CT (in 136 patients) and/or brain MRI (in 109 patients) before surgery. Pathologic N staging and dedicated standard imaging or follow-up imaging findings for M staging were used as reference standards. The median follow-up time was 47.9 months. On PET/CT scan, abnormal FDG uptake of lymph nodes was found in 2 of 136 patients (1.5%); both were negative on final pathology. Abnormal FDG uptake of the liver was detected in 1 patient, which was also confirmed to be negative by dedicated abdominal CT. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of PET/CT in detecting metastases were not applicable, 98% (95% confidence interval [CI], 94%-100%), 0% (95% CI, 0%-71%), 100% (95% CI, 97%-100%), and 98% (95% CI, 94%-100%), respectively. No brain metastasis was found in preoperative brain MRI of 109 patients. Of 109 patients, 1 (0.9%) developed brain metastasis 30 months after surgical resection. PET/CT and brain MRI is not necessary in the staging of pure GGO nodular lung adenocarcinoma. Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  15. Opacity

    International Nuclear Information System (INIS)

    Reina N, Ramon

    2003-01-01

    Their objective is to specify and to clarify many of the terms that are frequently employees and routinely in the description of the discoveries that appear in the x-rays of the thorax and in its complementary studies as it is the case of the computerized tomography; for the previous reason, it is considered important to include the term of opacity this it should be the first term to use when it is an abnormal discovery in the x-ray that causes an increase in the lung density of any etiology

  16. Opacity annotation of diffuse lung diseases using deep convolutional neural network with multi-channel information

    Science.gov (United States)

    Mabu, Shingo; Kido, Shoji; Hashimoto, Noriaki; Hirano, Yasushi; Kuremoto, Takashi

    2018-02-01

    This research proposes a multi-channel deep convolutional neural network (DCNN) for computer-aided diagnosis (CAD) that classifies normal and abnormal opacities of diffuse lung diseases in Computed Tomography (CT) images. Because CT images are gray scale, DCNN usually uses one channel for inputting image data. On the other hand, this research uses multi-channel DCNN where each channel corresponds to the original raw image or the images transformed by some preprocessing techniques. In fact, the information obtained only from raw images is limited and some conventional research suggested that preprocessing of images contributes to improving the classification accuracy. Thus, the combination of the original and preprocessed images is expected to show higher accuracy. The proposed method realizes region of interest (ROI)-based opacity annotation. We used lung CT images taken in Yamaguchi University Hospital, Japan, and they are divided into 32 × 32 ROI images. The ROIs contain six kinds of opacities: consolidation, ground-glass opacity (GGO), emphysema, honeycombing, nodular, and normal. The aim of the proposed method is to classify each ROI into one of the six opacities (classes). The DCNN structure is based on VGG network that secured the first and second places in ImageNet ILSVRC-2014. From the experimental results, the classification accuracy of the proposed method was better than the conventional method with single channel, and there was a significant difference between them.

  17. Quantitative CT analysis of pulmonary ground-glass opacity nodules for distinguishing invasive adenocarcinoma from non-invasive or minimally invasive adenocarcinoma: the added value of using iodine mapping

    International Nuclear Information System (INIS)

    Son, Ji Ye; Lee, Ho Yun; Kim, Jae-Hun; Lee, Kyung Soo; Han, Joungho; Jeong, Ji Yun; Kwon, O.J.; Shim, Young Mog

    2016-01-01

    To determine whether quantitative analysis of iodine-enhanced images generated from dual-energy CT (DECT) have added value in distinguishing invasive adenocarcinoma from non-invasive or minimally invasive adenocarcinoma (MIA) showing ground-glass nodule (GGN). Thirty-four patients with 39 GGNs were enrolled in this prospective study and underwent DECT followed by complete tumour resection. Various quantitative imaging parameters were assessed, including virtual non-contrast (VNC) imaging and iodine-enhanced imaging. Of all 39 GGNs, four were adenocarcinoma in situ (AIS) (10 %), nine were MIA (23 %), and 26 were invasive adenocarcinoma (67 %). When assessing only VNC imaging, multivariate analysis revealed that mass, uniformity, and size-zone variability were independent predictors of invasive adenocarcinoma (odds ratio [OR] = 19.92, P = 0.02; OR = 0.70, P = 0.01; OR = 16.16, P = 0.04, respectively). After assessing iodine-enhanced imaging with VNC imaging, both mass on the VNC imaging and uniformity on the iodine-enhanced imaging were independent predictors of invasive adenocarcinoma (OR = 5.51, P = 0.04 and OR = 0.67, P < 0.01). The power of diagnosing invasive adenocarcinoma was improved after adding the iodine-enhanced imaging parameters versus VNC imaging alone, from 0.888 to 0.959, respectively (P = 0.029). Quantitative analysis using iodine-enhanced imaging metrics versus VNC imaging metrics alone generated from DECT have added value in distinguishing invasive adenocarcinoma from AIS or MIA. (orig.)

  18. Quantitative CT analysis of pulmonary ground-glass opacity nodules for distinguishing invasive adenocarcinoma from non-invasive or minimally invasive adenocarcinoma: the added value of using iodine mapping

    Energy Technology Data Exchange (ETDEWEB)

    Son, Ji Ye; Lee, Ho Yun; Kim, Jae-Hun; Lee, Kyung Soo [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, 81 Irwon-Ro, Gangnam-gu, Seoul (Korea, Republic of); Han, Joungho [Sungkyunkwan University School of Medicine, Department of Pathology, Samsung Medical Center, Seoul (Korea, Republic of); Jeong, Ji Yun [Sungkyunkwan University School of Medicine, Department of Pathology, Samsung Medical Center, Seoul (Korea, Republic of); Kyungpook National University Medical Center, Kyungpook National University School of Medicine, Department of Pathology, Daegu (Korea, Republic of); Kwon, O.J. [Sungkyunkwan University School of Medicine, Division of Respiratory and Critical Medicine of the Department of Internal Medicine, Samsung Medical Center, Seoul (Korea, Republic of); Shim, Young Mog [Sungkyunkwan University School of Medicine, Department of Thoracic and Cardiovascular Surgery, Samsung Medical Center, 81 Irwon-Ro, Gangnam-gu, Seoul (Korea, Republic of)

    2016-01-15

    To determine whether quantitative analysis of iodine-enhanced images generated from dual-energy CT (DECT) have added value in distinguishing invasive adenocarcinoma from non-invasive or minimally invasive adenocarcinoma (MIA) showing ground-glass nodule (GGN). Thirty-four patients with 39 GGNs were enrolled in this prospective study and underwent DECT followed by complete tumour resection. Various quantitative imaging parameters were assessed, including virtual non-contrast (VNC) imaging and iodine-enhanced imaging. Of all 39 GGNs, four were adenocarcinoma in situ (AIS) (10 %), nine were MIA (23 %), and 26 were invasive adenocarcinoma (67 %). When assessing only VNC imaging, multivariate analysis revealed that mass, uniformity, and size-zone variability were independent predictors of invasive adenocarcinoma (odds ratio [OR] = 19.92, P = 0.02; OR = 0.70, P = 0.01; OR = 16.16, P = 0.04, respectively). After assessing iodine-enhanced imaging with VNC imaging, both mass on the VNC imaging and uniformity on the iodine-enhanced imaging were independent predictors of invasive adenocarcinoma (OR = 5.51, P = 0.04 and OR = 0.67, P < 0.01). The power of diagnosing invasive adenocarcinoma was improved after adding the iodine-enhanced imaging parameters versus VNC imaging alone, from 0.888 to 0.959, respectively (P = 0.029). Quantitative analysis using iodine-enhanced imaging metrics versus VNC imaging metrics alone generated from DECT have added value in distinguishing invasive adenocarcinoma from AIS or MIA. (orig.)

  19. Quantitative CT analysis of pulmonary ground-glass opacity nodules for distinguishing invasive adenocarcinoma from non-invasive or minimally invasive adenocarcinoma: the added value of using iodine mapping.

    Science.gov (United States)

    Son, Ji Ye; Lee, Ho Yun; Kim, Jae-Hun; Han, Joungho; Jeong, Ji Yun; Lee, Kyung Soo; Kwon, O Jung; Shim, Young Mog

    2016-01-01

    To determine whether quantitative analysis of iodine-enhanced images generated from dual-energy CT (DECT) have added value in distinguishing invasive adenocarcinoma from non-invasive or minimally invasive adenocarcinoma (MIA) showing ground-glass nodule (GGN). Thirty-four patients with 39 GGNs were enrolled in this prospective study and underwent DECT followed by complete tumour resection. Various quantitative imaging parameters were assessed, including virtual non-contrast (VNC) imaging and iodine-enhanced imaging. Of all 39 GGNs, four were adenocarcinoma in situ (AIS) (10 %), nine were MIA (23 %), and 26 were invasive adenocarcinoma (67 %). When assessing only VNC imaging, multivariate analysis revealed that mass, uniformity, and size-zone variability were independent predictors of invasive adenocarcinoma (odds ratio [OR] = 19.92, P = 0.02; OR = 0.70, P = 0.01; OR = 16.16, P = 0.04, respectively). After assessing iodine-enhanced imaging with VNC imaging, both mass on the VNC imaging and uniformity on the iodine-enhanced imaging were independent predictors of invasive adenocarcinoma (OR = 5.51, P = 0.04 and OR = 0.67, P VNC imaging alone, from 0.888 to 0.959, respectively (P = 0.029). Quantitative analysis using iodine-enhanced imaging metrics versus VNC imaging metrics alone generated from DECT have added value in distinguishing invasive adenocarcinoma from AIS or MIA. Quantitative analysis using DECT was used to distinguish invasive adenocarcinoma. Tumour mass and uniformity were independent predictors of invasive adenocarcinoma. Diagnostic performance was improved after adding iodine parameters to VNC parameters.

  20. Opacidades em vidro fosco nas doenças pulmonares difusas: correlação da tomografia computadorizada de alta resolução com a anatomopatologia Ground-glass opacity in diffuse lung diseases: high-resolution computed tomography-pathology correlation

    Directory of Open Access Journals (Sweden)

    Maria Lúcia de Oliveira Santos

    2003-12-01

    Full Text Available Opacidade em vidro fosco é achado freqüentemente visto na tomografia computadorizada de alta resolução do tórax e se traduz pelo aumento do coeficiente de atenuação dos pulmões, mas sem apagar as marcas broncovasculares. Por sua inespecificidade, a associação com outros achados radiológicos, clínicos e anatomopatológicos deve ser considerada para uma interpretação diagnóstica mais correta. Neste trabalho foram analisados 62 exames tomográficos de pacientes com doenças pulmonares difusas, de 14 etiologias diferentes, em que opacidades em vidro fosco foram o achado único ou predominante, e feita correlação anatomopatológica por meio de biópsias ou necropsias. Na pneumocistose as opacidades em vidro fosco corresponderam, histologicamente, à ocupação alveolar por material espumoso contendo parasitos; no carcinoma bronquíolo-alveolar, a espessamento dos septos alveolares e ocupação de sua luz por muco e células tumorais; na paracoccidioidomicose, a espessamento dos septos alveolares, áreas de fibrose e alvéolos contendo exsudato broncopneumônico; na sarcoidose, a fibrose ou a acúmulo de granulomas; na fibrose pulmonar idiopática, a espessamento dos septos alveolares por fibrose; na bronquiolite obliterante com pneumonia em organização, a pneumonia intersticial com áreas de organização intra-alveolar. A ocupação alveolar por sangue foi observada nos casos de leptospirose, hemossiderose idiopática, metástases de tumor renal e na aspergilose invasiva; por vacúolos de gordura na pneumonia lipídica; por material protéico e lipoprotéico na silicoproteinose e na proteinose alveolar; e por líquido de edema na insuficiência cardíaca congestiva.Ground-glass opacity is a finding frequently seen in high-resolution computed tomography examinations of the chest and is characterized by hazy increased attenuation of lung, however without blurring of bronchial and vascular margins. Due to its unspecificity

  1. Assessment of subpleural opacities on high-resolution CT

    International Nuclear Information System (INIS)

    Choi, Hee Seok; Kim, Jeung Sook; Kang, Eun Young; Kim, Hak Hee

    2007-01-01

    The purpose of this study was to assess the value of HRCT for determining the cause of subpleural opacities. We evaluated 49 cases of subpleural opacities on HRCT scan, among with the patients with subpleural opacities seen on the conventional chest radiographs. Two 'blinded' reviewers retrospectively analyzed the CT scans by working in consensus. The patients consisted of COP (n = 14), NSIP (n = 13), UIP (n = 10), fibrosis associated with connective tissue disease or drug toxicity (n = 4), CEP (n = 4), Churg-Strauss syndrome (n = 2), DIP (n = 1) and AIP (n = 1). The predominant findings were consolidation (57%) with a peribronchovascular distribution (57%) in the COP patients, GGO (69%) and the associated focal reticular densities (61%) in the NSIP patients, and reticular or reticulonodular densities with a paucity of GGO in the UIP patients (100%). For the diagnosis of COP, NSIP and UIP, the use of HRCT demonstrated a high sensitivity (86%, 85% and 90%, respectively), specificity (97%, 86% and 95%) and accuracy (94%, 86% and 94%). Although an overlap of CT findings is seen for diseases showing subpleural opacities, consolidation with a subpleural and peribronchovascular distribution is highly suggestive for COP, subpleural GGO is highly suggestive of NSIP, subpleural reticular or reticulonodular densities with a paucity of GGO is highly suggestive of UIP and subpleural consolidation accompanied by reticular densities is suggestive of fibrosis

  2. Assessment of subpleural opacities on high-resolution CT

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Hee Seok; Kim, Jeung Sook [Dngguk University International Hospital, Goyang (Korea, Republic of); Kang, Eun Young [Korea University Guro Hospital, Seoul (Korea, Republic of); Kim, Hak Hee [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2007-11-15

    The purpose of this study was to assess the value of HRCT for determining the cause of subpleural opacities. We evaluated 49 cases of subpleural opacities on HRCT scan, among with the patients with subpleural opacities seen on the conventional chest radiographs. Two 'blinded' reviewers retrospectively analyzed the CT scans by working in consensus. The patients consisted of COP (n = 14), NSIP (n = 13), UIP (n = 10), fibrosis associated with connective tissue disease or drug toxicity (n = 4), CEP (n = 4), Churg-Strauss syndrome (n = 2), DIP (n = 1) and AIP (n = 1). The predominant findings were consolidation (57%) with a peribronchovascular distribution (57%) in the COP patients, GGO (69%) and the associated focal reticular densities (61%) in the NSIP patients, and reticular or reticulonodular densities with a paucity of GGO in the UIP patients (100%). For the diagnosis of COP, NSIP and UIP, the use of HRCT demonstrated a high sensitivity (86%, 85% and 90%, respectively), specificity (97%, 86% and 95%) and accuracy (94%, 86% and 94%). Although an overlap of CT findings is seen for diseases showing subpleural opacities, consolidation with a subpleural and peribronchovascular distribution is highly suggestive for COP, subpleural GGO is highly suggestive of NSIP, subpleural reticular or reticulonodular densities with a paucity of GGO is highly suggestive of UIP and subpleural consolidation accompanied by reticular densities is suggestive of fibrosis.

  3. Pulmonary adenocarcinomas appearing as part-solid ground-glass nodules: Is measuring solid component size a better prognostic indicator?

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Eui Jin; Ryu, Youngjin; Lee, Sang Min [Seoul National University Medical Research Center, Department of Radiology, Seoul National University College of Medicine, and Institute of Radiation Medicine, 101, Daehangno, Jongno-gu, Seoul (Korea, Republic of); Park, Chang Min; Goo, Jin Mo [Seoul National University Medical Research Center, Department of Radiology, Seoul National University College of Medicine, and Institute of Radiation Medicine, 101, Daehangno, Jongno-gu, Seoul (Korea, Republic of); Seoul National University, Cancer Research Institute, Seoul (Korea, Republic of); Kim, Young Tae [Seoul National University, Cancer Research Institute, Seoul (Korea, Republic of); Seoul National University College of Medicine, Department of Thoracic and Cardiovascular Surgery, Seoul (Korea, Republic of); Kim, Young Whan [Seoul National University College of Medicine, Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine and Lung Institute, Seoul (Korea, Republic of)

    2014-10-02

    To assess whether measuring the solid portion of adenocarcinomas appearing as part-solid ground-glass nodules (GGNs) can predict a patient's prognosis accurately and how the prognosis corresponds to that of solid nodules. 501 patients (solid nodule group, 304; part-solid GGN group, 197) underwent curative surgery for stage I adenocarcinomas. Maximal diameters of the whole lesion including ground-glass opacities (D{sub whole}) and solid components only (D{sub solid}) were measured on CT. Disease-free survival (DFS) and overall survival (OS) were calculated from the date of surgery. D{sub solid} was a significant prognostic factor in the part-solid GGN group, while D{sub whole} was not. Part-solid GGNs with D{sub solid} ≤2 cm showed significantly better DFS (P = 0.016) and OS (P = 0.004) than solid nodules; however, those with D{sub solid} >2 cm did not show a significant difference. Hazard ratio (HR) for increase in D{sub solid} was significantly greater in part-solid GGNs than in solid nodules (P = 0.009). For OS, HR for increase in D{sub solid} was greater in part-solid GGNs than in solid nodule, which was marginally not significant (P = 0.060). D{sub solid} was better than D{sub whole} for prognosis prediction of adenocarcinomas appearing as part-solid GGNs. In addition, the influence of D{sub solid} on prognosis in the part-solid GGN group was greater than in the solid nodule group. (orig.)

  4. Asset Opacity and Liquidity

    OpenAIRE

    Stenzel, A.; Wagner, W.B.

    2013-01-01

    Abstract: We consider a model of private information acquisition in which the cost of information depends on an asset's opacity. The model generates a hump-shaped relationship between opacity and the equilibrium amount of private information. In particular, the incentives to acquire information are largest for assets of intermediate opacity; such assets hence display low liquidity in the secondary market due to adverse selection. We also show that costly information acquisition generates ince...

  5. Consistent interactive segmentation of pulmonary ground glass nodules identified in CT studies

    Science.gov (United States)

    Zhang, Li; Fang, Ming; Naidich, David P.; Novak, Carol L.

    2004-05-01

    Ground glass nodules (GGNs) have proved especially problematic in lung cancer diagnosis, as despite frequently being malignant they characteristically have extremely slow rates of growth. This problem is further magnified by the small size of many of these lesions now being routinely detected following the introduction of multislice CT scanners capable of acquiring contiguous high resolution 1 to 1.25 mm sections throughout the thorax in a single breathhold period. Although segmentation of solid nodules can be used clinically to determine volume doubling times quantitatively, reliable methods for segmentation of pure ground glass nodules have yet to be introduced. Our purpose is to evaluate a newly developed computer-based segmentation method for rapid and reproducible measurements of pure ground glass nodules. 23 pure or mixed ground glass nodules were identified in a total of 8 patients by a radiologist and subsequently segmented by our computer-based method using Markov random field and shape analysis. The computer-based segmentation was initialized by a click point. Methodological consistency was assessed using the overlap ratio between 3 segmentations initialized by 3 different click points for each nodule. The 95% confidence interval on the mean of the overlap ratios proved to be [0.984, 0.998]. The computer-based method failed on two nodules that were difficult to segment even manually either due to especially low contrast or markedly irregular margins. While achieving consistent manual segmentation of ground glass nodules has proven problematic most often due to indistinct boundaries and interobserver variability, our proposed method introduces a powerful new tool for obtaining reproducible quantitative measurements of these lesions. It is our intention to further document the value of this approach with a still larger set of ground glass nodules.

  6. Asset Opacity and Liquidity

    NARCIS (Netherlands)

    Stenzel, A.; Wagner, W.B.

    2013-01-01

    Abstract: We consider a model of private information acquisition in which the cost of information depends on an asset's opacity. The model generates a hump-shaped relationship between opacity and the equilibrium amount of private information. In particular, the incentives to acquire information are

  7. Data on the quantitative assessment pulmonary ground-glass opacification from coronary computed tomography angiography datasets

    DEFF Research Database (Denmark)

    Kühl, J Tobias; Kristensen, Thomas S; Thomsen, Anna F

    2017-01-01

    We assessed the CT attenuation density of the pulmonary tissue adjacent to the heart in patients with acute non-ST segment elevation myocardial infarction (J.T. Kuhl, T.S. Kristensen, A.F. Thomsen et al., 2016) [1]. This data was related to the level of ground-glass opacification evaluated by a r...

  8. Computer-Aided Segmentation and Volumetry of Artificial Ground-Glass Nodules at Chest CT

    NARCIS (Netherlands)

    Scholten, Ernst Th.; Jacobs, Colin; van Ginneken, Bram; Willemink, Martin J.; Kuhnigk, Jan-Martin; van Ooijen, Peter M. A.; Oudkerk, Matthijs; Mali, Willem P. Th. M.; de Jong, Pim A.

    OBJECTIVE. The purpose of this study was to investigate a new software program for semiautomatic measurement of the volume and mass of ground-glass nodules (GGNs) in a chest phantom and to investigate the influence of CT scanner, reconstruction filter, tube voltage, and tube current. MATERIALS AND

  9. Astrophysical opacity library

    International Nuclear Information System (INIS)

    Huebner, W.F.; Merts, A.L.; Magee, N.H. Jr.; Argo, M.F.

    1977-08-01

    The astrophysical elements opacity library includes equation of state data, various mean opacities, and 2000 values of the frequency-dependent extinction coefficients in equally spaced intervals u identical with hν/kT from 0 to 20 for 41 degeneracy parameters eta from -28 (nondegenerate) to 500 and 46 temperatures kT from 1 eV to 100 keV. Among available auxiliary quantities are the free electron density, mass density, and plasma cutoff frequency. A library-associated program can produce opacities for mixtures with up to 20 astrophysically abundant constituent elements at 4 levels of utility for the user

  10. Lanthanide/Actinide Opacities

    Science.gov (United States)

    Hungerford, Aimee; Fontes, Christopher J.

    2018-06-01

    Gravitational wave observations benefit from accompanying electromagnetic signals in order to accurately determine the sky positions of the sources. The ejecta of neutron star mergers are expected to produce such electromagnetic transients, called macronovae (e.g. the recent and unprecedented observation of GW170817). Characteristics of the ejecta include large velocity gradients and the presence of heavy r-process elements, which pose significant challenges to the accurate calculation of radiative opacities and radiation transport. Opacities include a dense forest of bound-bound features arising from near-neutral lanthanide and actinide elements. Here we present an overview of current theoretical opacity determinations that are used by neutron star merger light curve modelers. We will touch on atomic physics and plasma modeling codes that are used to generate these opacities, as well as the limited body of laboratory experiments that may serve as points of validation for these complex atomic physics calculations.

  11. Ground Glass Pozzolan in Conventional, High, and Ultra-High Performance Concrete

    OpenAIRE

    Tagnit-Hamou Arezki; Zidol Ablam; Soliman Nancy; Deschamps Joris; Omran Ahmed

    2018-01-01

    Ground-glass pozzolan (G) obtained by grinding the mixed-waste glass to same fineness of cement can act as a supplementary-cementitious material (SCM), given that it is an amorphous and a pozzolanic material. The G showed promising performances in different concrete types such as conventional concrete (CC), high-performance concrete (HPC), and ultra-high performance concrete (UHPC). The current paper reports on the characteristics and performance of G in these concrete types. The use of G pro...

  12. OPACs in the Clouds

    Science.gov (United States)

    Webb, Paula L.; Nero, Muriel D.

    2009-01-01

    In today's world of instant everything, everyone has been exposed to some form of Web 2.0 technology, and higher education is not exempt from its long reach. Libraries of all types are incorporating Web 2.0 features to attract users as well as to showcase library services. The Online Public Access Catalog (OPAC) has become more user-friendly with…

  13. Thus Spake the OPAC User.

    Science.gov (United States)

    Markey, Karen

    1983-01-01

    Findings of focused-group interviews conducted for OCLC study of library users and online public access catalogs (OPACs) indicate users like OPACs, have problems finding right subject heading, envision features to improve subject access, want access to more than books, and want OPACs to provide new services. Eight references are listed. (EJS)

  14. Universe opacity and CMB

    Science.gov (United States)

    Vavryčuk, Václav

    2018-04-01

    A cosmological model, in which the cosmic microwave background (CMB) is a thermal radiation of intergalactic dust instead of a relic radiation of the Big Bang, is revived and revisited. The model suggests that a virtually transparent local Universe becomes considerably opaque at redshifts z > 2 - 3. Such opacity is hardly to be detected in the Type Ia supernova data, but confirmed using quasar data. The opacity steeply increases with redshift because of a high proper density of intergalactic dust in the previous epochs. The temperature of intergalactic dust increases as (1 + z) and exactly compensates the change of wavelengths due to redshift, so that the dust radiation looks apparently like the radiation of the blackbody with a single temperature. The predicted dust temperature is TD = 2.776 K, which differs from the CMB temperature by 1.9% only, and the predicted ratio between the total CMB and EBL intensities is 13.4 which is close to 12.5 obtained from observations. The CMB temperature fluctuations are caused by EBL fluctuations produced by galaxy clusters and voids in the Universe. The polarization anomalies of the CMB correlated with temperature anisotropies are caused by the polarized thermal emission of needle-shaped conducting dust grains aligned by large-scale magnetic fields around clusters and voids. A strong decline of the luminosity density for z > 4 is interpreted as the result of high opacity of the Universe rather than of a decline of the global stellar mass density at high redshifts.

  15. Recent progress on astrophysical opacity

    International Nuclear Information System (INIS)

    Rogers, F.J.; Iglesias, C.A.

    1992-08-01

    Improvements in the calculation of the opacity of astrophysical plasmas has helped to resolve several long-standing puzzles in the modeling of variable stars. The most significant opacity enhancements over the Los Alamos Astrophysical Library (LAOL) are due to improvements in the equation of state and atomic physics. Comparison with experiment has corroborated the predicted large opacity increases due to transitions in M-shell iron. We give a summary of recent developments

  16. Radiographic findings of miliary tuberculosis: difference in patients with and those without associated acute respiratory failure

    International Nuclear Information System (INIS)

    Kim, Min Jeong; Lee, Jin Seong; Ko, Yoon Seok; Lee, In Sun; Seo, Joon Beom; Song, Koun Sick; Lim, Tae Hwan

    2002-01-01

    To determine the differences in the radiography findings of miliary tuberculosis between patients with and without associated acute respiratory failure (ARF). We retrospectively 32 patients in whom miliary tuberculosis had been diagnosed, and assigned them to one of two groups: with ARF (n=10), and without ARF (n=22). Chest radiographic findings such as presence of miliary modules, consolidation, ground-glass opacity (GGO), pleural effusion, small calcified nodules and linear opacities were assessed, the size and profusion of nodules in each of four zones were analyzed and scored using the standard radiographs of the international labor organization, and the extent of consolidation and GGO were scored according to the percentage on involved lung. We compared the radiologic findings between the two groups. Ground-glass opacity, consolidation, and pleural effusion were seen more frequently in miliary tuberculosis patinets with ARF than in those without ARF. Although the size and profusion of nodules were similar in both groups (p>0.05), consolidation and ground-glass opacity in cases of miliary tuberculosis with ARF were significantly more extensive than in those without ARF (p<0.005). GGO and consolidation were more extensive in miliary tuberculosis patients with ARF. A finding of ground-glass opacity in miliary tuberculosis patients might be an early indication of developing ARF

  17. Chest CT findings of toxocariasis: Correlation with laboratory results

    International Nuclear Information System (INIS)

    Hur, J.H.; Lee, I.J.; Kim, J.-H.; Kim, D.-G.; Hwang, H.J.; Koh, S.H.; Lee, K.

    2014-01-01

    Aim: To assess the relationship between chest computed tomography (CT) findings of patients with toxocariasis and levels of serological markers. Materials and methods: A total of 38 cases of patients diagnosed with toxocariasis by enzyme-linked immunosorbent assay (ELISA), CT, and serological markers were retrospectively reviewed. The presence of nodule with or without ground-glass opacity (GGO) halo, consolidation, focal GGO, pleural effusion, and lymphadenopathy at chest CT were evaluated. Statistical analysis was performed with the Fisher's exact test. Results: The most common chest CT findings were nodule (n = 12, 31.6%) and focal GGO (n = 12, 31.6%). In patients with normal eosinophil levels, focal GGO (n = 9, 37.5%) was the most common finding. In contrast, nodule with a GGO halo (n = 7, 50%) was the most common finding in the eosinophilia group. Nodule with a GGO halo was more common in the eosinophilia group, with a statistically significant difference (p = 0.017). Nodule was more common in the eosinophilia group, and focal GGO was more common in the normal eosinophil group. Conclusion: The most common chest CT findings in toxocariasis were nodule with or without GGO halo, and focal GGO. In the eosinophilia group, nodule with a GGO halo was significantly more frequent. Other CT findings did not show a statistically significant relationship with serological markers

  18. Web OPAC Interfaces: An Overview.

    Science.gov (United States)

    Babu, B. Ramesh; O'Brien, Ann

    2000-01-01

    Discussion of Web-based online public access catalogs (OPACs) focuses on a review of six Web OPAC interfaces in use in academic libraries in the United Kingdom. Presents a checklist and guidelines of important features and functions that are currently available, including search strategies, access points, display, links, and layout. (Author/LRW)

  19. Helioseismic Tests of Radiative Opacities.

    Energy Technology Data Exchange (ETDEWEB)

    Guzik, J. A. (Joyce Ann); Neuforge, C. M. (Corinne M.); Keady, J. J.; Magee, N. H. (Norman H.); Bradley, P. A. (Paul A.)

    2002-01-01

    During the past fifteen years, thousands of solar acoustic oscillation modes have been measured to remarkable precision, in many cases to within 0.01%. These frequencies have been used to infer the interior structure of the sun and test the physical input to solar models. Here we summarize the procedures, input physics and assumptions for calculating a standard solar evolution model. We compare the observed and calculated sound speed profile and oscillation frequencies of solar models calibrated using the new Los Alamos LEDCOP and Livermore OPAL Rosseland mean opacities for the same element mixture. We show that solar oscillations are extremely sensitive to opacities, with opacity differences of only a few percent producing an easily detectable effect on the sound speed and predicted frequencies. The oscillation data indicate that agreement would be improved by an opacity increase of several percent below the convection zone for both the LEDCOP and OPAL opacities.

  20. Preparation of concrete mixtures with electric arc furnace slag and recycled ground glass

    Science.gov (United States)

    Pérez Rojas, Y.; López, E. Vera; López Rodríguez, M.; Díaz Pita, J.

    2017-12-01

    The present work includes the first advances in the development of investigations that seek to include Ground Grinding Glass (GRR) and the Electric Arc Furnace Slag (EAFS) in the production of mixtures of hydraulic concrete mixing them simultaneously, so that it satisfies the specifications techniques to be used in the construction of rigid pavements. Firstly, we cite the tests carried out on the different materials to obtain their physical, chemical and mechanical characterization and determine their compliance, as well as the measurement of certain characteristics that may be somewhat empirical to standardize their control. Technique such as X-Ray Diffraction (XRD), X-ray Fluorescence Spectrometry (XFR) and Scanning Electron Microscopy (SEM) have been used. Once the results of the characterization tests and their correspondence with the Colombian technical standards have been obtained, it has become possible to select the use of the Transparent Recycled Ground Glass (TRGG) as the most suitable for the replacement of the sand in the dosage of new mixtures modified concrete.

  1. Ground Glass Pozzolan in Conventional, High, and Ultra-High Performance Concrete

    Directory of Open Access Journals (Sweden)

    Tagnit-Hamou Arezki

    2018-01-01

    Full Text Available Ground-glass pozzolan (G obtained by grinding the mixed-waste glass to same fineness of cement can act as a supplementary-cementitious material (SCM, given that it is an amorphous and a pozzolanic material. The G showed promising performances in different concrete types such as conventional concrete (CC, high-performance concrete (HPC, and ultra-high performance concrete (UHPC. The current paper reports on the characteristics and performance of G in these concrete types. The use of G provides several advantages (technological, economical, and environmental. It reduces the production cost of concrete and decrease the carbon footprint of a traditional concrete structures. The rheology of fresh concrete can be improved due to the replacement of cement by non-absorptive glass particles. Strength and rigidity improvements in the concrete containing G are due to the fact that glass particles act as inclusions having a very high strength and elastic modulus that have a strengthening effect on the overall hardened matrix.

  2. Software-based risk stratification of pulmonary adenocarcinomas manifesting as pure ground glass nodules on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Nemec, Ursula [Vienna General Hospital, Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Heidinger, Benedikt H.; Bankier, Alexander A. [Harvard Medical School, Radiology, Beth Israel Deaconess Medical Center, Boston, MA (United States); Anderson, Kevin R.; VanderLaan, Paul A. [Harvard Medical School, Pathology, Beth Israel Deaconess Medical Center, Boston, MA (United States); Westmore, Michael S. [Imbio, Delafield, WI (United States)

    2018-01-15

    To assess the performance of the ''Computer-Aided Nodule Assessment and Risk Yield'' (CANARY) software in the differentiation and risk assessment of histological subtypes of lung adenocarcinomas manifesting as pure ground glass nodules on computed tomography (CT). 64 surgically resected and histologically proven adenocarcinomas manifesting as pure ground-glass nodules on CT were assessed using CANARY software, which classifies voxel-densities into three risk components (low, intermediate, and high risk). Differences in risk components between histological adenocarcinoma subtypes were analysed. To determine the optimal threshold reflecting the presence of an invasive focus, sensitivity, specificity, negative predictive value, and positive predictive value were calculated. 28/64 (44%) were adenocarcinomas in situ (AIS); 26/64 (41%) were minimally invasive adenocarcinomas (MIA); and 10/64 (16%) were invasive ACs (IAC). The software showed significant differences in risk components between histological subtypes (P<0.001-0.003). A relative volume of 45% or less of low-risk components was associated with histological invasiveness (specificity 100%, positive predictive value 100%). CANARY-based risk assessment of ACs manifesting as pure ground glass nodules on CT allows the differentiation of their histological subtypes. A threshold of 45% of low-risk components reflects invasiveness in these groups. (orig.)

  3. Software-based risk stratification of pulmonary adenocarcinomas manifesting as pure ground glass nodules on computed tomography

    International Nuclear Information System (INIS)

    Nemec, Ursula; Heidinger, Benedikt H.; Bankier, Alexander A.; Anderson, Kevin R.; VanderLaan, Paul A.; Westmore, Michael S.

    2018-01-01

    To assess the performance of the ''Computer-Aided Nodule Assessment and Risk Yield'' (CANARY) software in the differentiation and risk assessment of histological subtypes of lung adenocarcinomas manifesting as pure ground glass nodules on computed tomography (CT). 64 surgically resected and histologically proven adenocarcinomas manifesting as pure ground-glass nodules on CT were assessed using CANARY software, which classifies voxel-densities into three risk components (low, intermediate, and high risk). Differences in risk components between histological adenocarcinoma subtypes were analysed. To determine the optimal threshold reflecting the presence of an invasive focus, sensitivity, specificity, negative predictive value, and positive predictive value were calculated. 28/64 (44%) were adenocarcinomas in situ (AIS); 26/64 (41%) were minimally invasive adenocarcinomas (MIA); and 10/64 (16%) were invasive ACs (IAC). The software showed significant differences in risk components between histological subtypes (P<0.001-0.003). A relative volume of 45% or less of low-risk components was associated with histological invasiveness (specificity 100%, positive predictive value 100%). CANARY-based risk assessment of ACs manifesting as pure ground glass nodules on CT allows the differentiation of their histological subtypes. A threshold of 45% of low-risk components reflects invasiveness in these groups. (orig.)

  4. Quantitative CT analysis of pulmonary pure ground-glass nodule predicts histological invasiveness

    Energy Technology Data Exchange (ETDEWEB)

    Li, Qiong, E-mail: liqiongsmmu2008@qq.com [Department of Radiology, Changzheng Hospital, Second Military Medical University, NO. 415, Fengyang Road, Shanghai 200003 (China); Fan, Li, E-mail: fanli0930@163.com [Department of Radiology, Changzheng Hospital, Second Military Medical University, NO. 415, Fengyang Road, Shanghai 200003 (China); Cao, En-Tao, E-mail: cet123cs@126.com [Department of Radiology, Suzhou Municipal Hospital (East District), No.16 West Baita Road, Suzhu, Jiangsu Province 215001 (China); Li, Qing-Chu, E-mail: Wudi327@hotmail.com [Department of Radiology, Changzheng Hospital, Second Military Medical University, NO. 415, Fengyang Road, Shanghai 200003 (China); Gu, Ya-Feng, E-mail: 2528473557@qq.com [Department of Radiology, Changzheng Hospital, Second Military Medical University, NO. 415, Fengyang Road, Shanghai 200003 (China); Liu, Shi−Yuan, E-mail: liusy1186@163.com [Department of Radiology, Changzheng Hospital, Second Military Medical University, NO. 415, Fengyang Road, Shanghai 200003 (China)

    2017-04-15

    Objective: To assess whether quantitative computed tomography (CT) can help predict histological invasiveness of pulmonary adenocarcinoma appearing as pure ground glass nodules (pGGNs). Methods: A total of 110 pulmonary pGGNs were retrospectively evaluated, and pathologically classified as pre-invasive lesions, minimally invasive adenocarcinoma (MIA) and invasive pulmonary adenocarcinoma (IPA). Maximum nodule diameters, largest cross-sectional areas, volumes, mean CT values, weights, and CT attenuation values at the 0th,2th,5th, 25th, 50th,75th, 95th, 98th and100th percentiles on histogram, as well as 2th to 98th, 5th to 95th, 25th to 75th,and 0th to 100thslopes, respectively, were compared among the three groups. Results: Of the 110 pGGNs, 50, 28, and 32 were pre-invasive lesions, MIA, and IPA, respectively. Maximum nodule diameters, largest cross-sectional areas, andmass weights were significantly larger in the IPA group than in pre-invasive lesions. The 95th, 98th, 100th percentiles, and 2th to 98th, 25th to 75th, and 0th to 100thslopes were significantly different between pre-invasive lesions and MIA or IPA. Logistic regression analysis showed that the maximum nodule diameter (OR = 1.21, 95%CI: 1.071–1.366, p < 0.01) and 100th percentile on histogram (OR = 1.02, 95%CI: 1.009–1.032, p < 0.001) independently predicted histological invasiveness. Conclusions: Quantitative analysis of CT imaging can predict histological invasiveness of pGGNs, especiallythe maximum nodule diameter and 100th percentile on CT number histogram; this can instruct the long-term follow-up and selective surgical management.

  5. Radiogenomic correlation in lung adenocarcinoma with epidermal growth factor receptor mutations: Imaging features and histological subtypes

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Su Jin [Seoul National University Bundang Hospital, Department of Radiology, Seongnam-si, Gyeonggi-do (Korea, Republic of); Hanyang University, Department of Radiology, School of Medicine, Seoul (Korea, Republic of); Kim, Tae Jung [Seoul National University Bundang Hospital, Department of Radiology, Seongnam-si, Gyeonggi-do (Korea, Republic of); Samsung Medical Center, Department of Radiology, Seoul (Korea, Republic of); Choi, Yo Won [Hanyang University, Department of Radiology, School of Medicine, Seoul (Korea, Republic of); Park, Jeong-Soo [Dankook Universicity, Department of Biochemistry, College of Medicine, Cheonan (Korea, Republic of); Chung, Jin-Haeng [Seoul National University Bundang Hospital, Department of Pathology, Seongnam-si, Gyeonggi-do (Korea, Republic of); Lee, Kyung Won [Seoul National University Bundang Hospital, Department of Radiology, Seongnam-si, Gyeonggi-do (Korea, Republic of)

    2016-10-15

    To correlate imaging features of resected lung adenocarcinoma with epidermal growth factor receptor (EGFR) mutation and the IASLC/ATS/ERS classification histological subtypes. In 250 consecutive patients with resected lung adenocarcinoma, EGFR mutation status was correlated with demographics, imaging features including ground-glass opacity (GGO) proportion and the IASLC/ATS/ERS classification histological subtypes. EGFR mutations were significantly more frequent in women (54.5 % vs. 38.1 %, p = 0.011) and in never-smokers (54.7 % vs. 35.3 %, p = 0.003). GGO proportion was significantly higher in tumours with EGFR mutation than in those without (30.3 ± 33.8 % vs. 19.0 ± 29.3 %, p = 0.005). EGFR mutation was significantly more frequent in tumours with GGO ≥ 50 % and tumours with any GGO (p = 0.026 and 0.008, respectively). Adenocarcinomas with exon 19 or 21 mutation showed significantly higher GGO proportion than that in EGFR wild-type tumours (p = 0.009 and 0.029, respectively). Absence of GGO was an independent predictor of negative EGFR mutation (odds ratio, 1.81; 95 % confidence interval, 1.16-3.04; p = 0.018). GGO proportion in adenocarcinomas with EGFR mutation was significantly higher than that in EGFR wild-type tumours, and the absence of GGO on CT was an independent predictor of negative EGFR mutation. (orig.)

  6. LINE BROADENING AND THE SOLAR OPACITY PROBLEM

    Energy Technology Data Exchange (ETDEWEB)

    Krief, M.; Feigel, A.; Gazit, D., E-mail: menahem.krief@mail.huji.ac.il [The Racah Institute of Physics, The Hebrew University, 91904 Jerusalem (Israel)

    2016-06-20

    The calculation of line widths constitutes theoretical and computational challenges in the calculation of opacities of hot, dense plasmas. Opacity models use line broadening approximations that are untested at stellar interior conditions. Moreover, calculations of atomic spectra of the Sun indicate a large discrepancy in the K-shell line widths between several atomic codes and the Opacity-Project (OP). In this work, the atomic code STAR is used to study the sensitivity of solar opacities to line broadening. Variations in the solar opacity profile due to an increase of the Stark widths resulting from discrepancies with OP, are compared, in light of the solar opacity problem, with the required opacity variations of the present day Sun, as imposed by helioseismic and neutrino observations. The resulting variation profile is much larger than the discrepancy between different atomic codes, agrees qualitatively with the missing opacity profile, recovers about half of the missing opacity nearby the convection boundary, and has a little effect in the internal regions. Since it is hard to estimate quantitatively the uncertainty in the Stark widths, we show that an increase of all line widths by a factor of about ∼100 recovers quantitatively the missing opacity. These results emphasize the possibility that photoexcitation processes are not modeled properly, and more specifically, highlight the need for a better theoretical characterization of the line broadening phenomena at stellar interior conditions, and of the uncertainty due to the way it is implemented by atomic codes.

  7. Some investigations about the Carson opacities

    International Nuclear Information System (INIS)

    Cox, A.N.; Kidman, R.B.

    1983-01-01

    Accurate opacities for stellar composition mixtures are needed for all studies of stellar structure, evolution, stability, and pulsation. Three problem areas where increased opacities would be welcome are: the observed broadening of the upper main sequence that can be produced with larger opacities that tend to expand the stars; the existence of the double-mode Cepheids and their anomalously low period ratios which can be predicted to be lower, as observed, if opacities are larger; and the small sensitivity of the low mass population II horizontal branch luminosity to the metal content of their compositions that would be more effective if their opacity were increased. Several other problems that could be solved by larger opacities have been widely discussed, but we feel that they are not justifiably an opacity problem. The conclusion of our considerations are that the Thomas-Fermi method for getting opacities used by Carson and his collaborators does not produce values appreciably different from those obtained without this method at Los Alamos, and that these persistent astrophysical problems must be solved in other ways. We here propose a possible error in the Carson opacities, and, further, we mention another that seems to be the correct reconciliation between these two opacity sets

  8. Serendipity and Holism: The Beauty of OPACs.

    Science.gov (United States)

    Rice, James

    1988-01-01

    Identifies factors which may account for user dissatisfaction with online public access catalogs (OPACs) and discusses some advantages of OPACs over card catalogs: (1) design for subject searching; (2) flexibility; (3) browsing capability; (4) precision; (5) availability of status information; and (6) development of microcomputer software to…

  9. Using Web Services for a Mobile OPAC

    Directory of Open Access Journals (Sweden)

    Denis Galvin

    2011-04-01

    Full Text Available The purpose of this paper is to discuss the creation and intended evolution of the Rice University mobile online public access catalog (OPAC. The focus of the article is on how SirsiDynix’s Symphony Web Services can be used to create a mobile OPAC.

  10. Restricted fish feeding reduces cod otolith opacity

    DEFF Research Database (Denmark)

    Høie, H.; Folkvord, A.; Mosegaard, Henrik

    2008-01-01

    The purpose of this work was to examine the effect of reduced feeding and constant temperature on cod otolith opacity. Three groups of juvenile cod were given restricted food rations at different times for 4 months, resulting in depressed somatic growth. Otolith opacity was measured on pictures...... in otolith opacity were found between individual fish both within groups and between groups. In two of the three groups significantly more translucent otolith material was deposited in response to reduced feeding. Our results show that variations in feeding and hence fish growth resulted in variation...... in otolith opacity, but the effect was minor compared to that of variations in ambient temperature. The combined influence of these effects, which both act on fish metabolism, are most likely controlling the seasonal opacity changes observed in wild fish. Our results help explain the variations seen in fish...

  11. Opacity Limit for Supermassive Protostars

    Science.gov (United States)

    Becerra, Fernando; Marinacci, Federico; Inayoshi, Kohei; Bromm, Volker; Hernquist, Lars E.

    2018-04-01

    We present a model for the evolution of supermassive protostars from their formation at {M}\\star ≃ 0.1 {M}ȯ until their growth to {M}\\star ≃ {10}5 {M}ȯ . To calculate the initial properties of the object in the optically thick regime, we follow two approaches: one based on idealized thermodynamic considerations, and another based on a more detailed one-zone model. Both methods derive a similar value of {n}{{F}}≃ 2× {10}17 {cm}}-3 for the density of the object when opacity becomes important, i.e., the opacity limit. The subsequent evolution of the growing protostar is determined by the accretion of gas onto the object and can be described by a mass–radius relation of the form {R}\\star \\propto {M}\\star 1/3 during the early stages, and of the form {R}\\star \\propto {M}\\star 1/2 when internal luminosity becomes important. For the case of a supermassive protostar, this implies that the radius of the star grows from {R}\\star ≃ 0.65 {au} to {R}\\star ≃ 250 {au} during its evolution. Finally, we use this model to construct a subgrid recipe for accreting sink particles in numerical simulations. A prime ingredient thereof is a physically motivated prescription for the accretion radius and the effective temperature of the growing protostar embedded inside it. From the latter, we can conclude that photoionization feedback can be neglected until very late in the assembly process of the supermassive object.

  12. CT and histopathologic characteristics of lung adenocarcinoma with pure ground-glass nodules 10 mm or less in diameter

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Fang [Chinese PLA General Hospital, Department of Radiology, Beijing (China); Capital Medical University, Department of Radiology, Xuanwu Hospital, Beijing (China); Tian, Shu-ping [Navy General Hospital, Department of Radiology, Beijing (China); Jin, Xin; Jing, Rui; Yang, Yue-qing; Jin, Mei; Zhao, Shao-hong [Chinese PLA General Hospital, Department of Radiology, Beijing (China)

    2017-10-15

    To evaluate CT and histopathologic features of lung adenocarcinoma with pure ground-glass nodule (pGGN) ≤10 mm in diameter. CT appearances of 148 patients (150 lesions) who underwent curative resection of lung adenocarcinoma with pGGN ≤10 mm (25 atypical adenomatous hyperplasias, 42 adenocarcinoma in situs, 38 minimally invasive adenocarcinomas, and 45 invasive pulmonary adenocarcinomas) were analyzed for lesion size, density, bubble-like sign, air bronchogram, vessel changes, margin, and tumour-lung interface. CT characteristics were compared among different histopathologic subtypes. Univariate and multivariate analysis were used to assess the relationship between CT characteristics of pGGN and lesion invasiveness, respectively. There were statistically significant differences among histopathologic subtypes in lesion size, vessel changes, and tumour-lung interface (P<0.05). Univariate analysis revealed significant differences of vessel changes, margin and tumour-lung interface between preinvasive and invasive lesions (P<0.05). Logistic regression analysis showed that the vessel changes, unsmooth margin and clear tumour-lung interface were significant predictive factors for lesion invasiveness, with odds ratios (95% CI) of 2.57 (1.17-5.62), 1.83 (1.25-2.68) and 4.25 (1.78-10.14), respectively. Invasive lesions are found in 55.3% of subcentimeter pGGNs in our cohort. Vessel changes, unsmooth margin, and clear lung-tumour interface may indicate the invasiveness of lung adenocarcinoma with subcentimeter pGGN. (orig.)

  13. Multi-detector spiral CT study of the relationships between pulmonary ground-glass nodules and blood vessels

    International Nuclear Information System (INIS)

    Gao, Feng; Li, Ming; Ge, Xiaojun; Ren, Qingguo; Hua, Yanqing; Zheng, Xiangpeng; Chen, Yan; Lv, Fangzhen

    2013-01-01

    To investigate the relationships between pulmonary ground-glass nodules (GGN) and blood vessels and their diagnostic values in differentiating GGNs. Multi-detector spiral CT imaging of 108 GGNs was retrospectively reviewed. The spatial relationships between GGNs and supplying blood vessels were categorized into four types: I, vessels passing by GGNs; II, intact vessels passing through GGNs; III, distorted, dilated or tortuous vessels seen within GGNs; IV, more complicated vasculature other than described above. Relationship types were correlated to pathologic and/or clinical findings of GGNs. Of 108 GGNs, 10 were benign, 24 preinvasive nodules and 74 adenocarcinomas that were pathologically proven. Types I, II, III and IV vascular relationships were observed in 9, 58, 21 and 20 GGNs, respectively. Type II relationship was the dominating relationship for each GGN group, but significant differences were shown among them. Correlation analysis showed strong correlation between invasive adenocarcinoma and type III and IV relationships. Subgroup analysis indicated that type III was more commonly seen in IAC with comparison to type IV more likely seen in MIA. Different GGNs have different relationships with vessels. Understanding and recognising characteristic GGN-vessel relationships may help identify which GGNs are more likely to be malignant. (orig.)

  14. New Generation of Los Alamos Opacity Tables

    Science.gov (United States)

    Colgan, James; Kilcrease, D. P.; Magee, N. H.; Sherrill, M. E.; Abdallah, J.; Hakel, P.; Fontes, C. J.; Guzik, J. A.; Mussack, K. A.

    2016-05-01

    We present a new generation of Los Alamos OPLIB opacity tables that have been computed using the ATOMIC code. Our tables have been calculated for all 30 elements from hydrogen through zinc and are publicly available through our website. In this poster we discuss the details of the calculations that underpin the new opacity tables. We also show several recent applications of the use of our opacity tables to solar modeling and other astrophysical applications. In particular, we demonstrate that use of the new opacities improves the agreement between solar models and helioseismology, but does not fully resolve the long-standing `solar abundance' problem. The Los Alamos National Laboratory is operated by Los Alamos National Security, LLC for the National Nuclear Security Administration of the U.S. Department of Energy under Contract No. DE-AC5206NA25396.

  15. The neutrino opacity of neutron rich matter

    Energy Technology Data Exchange (ETDEWEB)

    Alcain, P.N., E-mail: pabloalcain@gmail.com [Departamento de Física, FCEyN, UBA and IFIBA, Conicet, Pabellón 1, Ciudad Universitaria, 1428 Buenos Aires (Argentina); IFIBA-CONICET (Argentina); Dorso, C.O. [Departamento de Física, FCEyN, UBA and IFIBA, Conicet, Pabellón 1, Ciudad Universitaria, 1428 Buenos Aires (Argentina); IFIBA-CONICET (Argentina)

    2017-05-15

    The study of neutron rich matter, present in neutron star, proto-neutron stars and core-collapse supernovae, can lead to further understanding of the behavior of nuclear matter in highly asymmetric nuclei. Heterogeneous structures are expected to exist in these systems, often referred to as nuclear pasta. We have carried out a systematic study of neutrino opacity for different thermodynamic conditions in order to assess the impact that the structure has on it. We studied the dynamics of the neutrino opacity of the heterogeneous matter at different thermodynamic conditions with semiclassical molecular dynamics model already used to study nuclear multifragmentation. For different densities, proton fractions and temperature, we calculate the very long range opacity and the cluster distribution. The neutrino opacity is of crucial importance for the evolution of the core-collapse supernovae and the neutrino scattering.

  16. Update on the opal opacity code

    International Nuclear Information System (INIS)

    Rogers, F.J.; Iglesias, C.A.; Wilson, B.G.

    1990-01-01

    Persisting discrepancies between theory and observation in a number of astrophysical properties has led to the conjecture that opacity databases may be inaccurate. The OPAL opacity code has been developed to address this question. The physical basis of OPAL removes several of the approximations present in past calculations. For example, it utilizes a much larger and more detailed set of atomic data than was used to construct the los Alamos Astrophysical Library. This data is generated online, in LS or intermediate coupling, from prefitted analytic effective potentials and is of similar quality as single configuration, relativistic, self-consistent-field calculations. The OPAL code has been used to calculate opacities for the solar core and for Cepheid variable stars. In both cases, significant increases in the opacity compared to the Los Alamos Astrophysical Library were found

  17. Summary of Fe opacity measurement platform

    Energy Technology Data Exchange (ETDEWEB)

    Nagayama, Taisuke

    2016-05-01

    This powerpoint presentation goes over the Fe opacity measurement platform, including how the experiment works, what can be gathered from the measurements, what can be gathered from the simulations, and the limitations of the experiment.

  18. Electrocardiography-triggered high-resolution CT for reducing cardiac motion artifact. Evaluation of the extent of ground-glass attenuation in patients with idiopathic pulmonary fibrosis

    International Nuclear Information System (INIS)

    Nishiura, Motoko; Johkoh, Takeshi; Yamamoto, Shuji

    2007-01-01

    The aim of this study was to evaluate the decreasing of cardiac motion artifact and whether the extent of ground-glass attenuation of idiopathic pulmonary fibrosis (IPF) was accurately assessed by electrocardiography (ECG)-triggered high-resolution computed tomography (HRCT) by 0.5-s/rotation multidetector-row CT (MDCT). ECG-triggered HRCT were scanned at the end-diastolic phase by a MDCT scanner with the following scan parameters; axial four-slice mode, 0.5 mm collimation, 0.5-s/rotation, 120 kVp, 200 mA/rotation, high-frequency algorithm, and half reconstruction. In 42 patients with IPF, both conventional HRCT (ECG gating (-), full reconstruction) and ECG-triggered HRCT were performed at the same levels (10-mm intervals) with the above scan parameters. The correlation between percent diffusion of carbon monoxide of the lung (%DLCO) and the mean extent of ground-glass attenuation on both conventional HRCT and ECG-triggered HRCT was evaluated with the Spearman rank correlation coefficient test. The correlation between %DLCO and the mean extent of ground-glass attenuation on ECG-triggered HRCT (observer A: r=-0.790, P<0.0001; observer B: r=-0.710, P<0.0001) was superior to that on conventional HRCT (observer A: r=-0.395, P<0.05; observer B: r=-0.577, P=0.002) for both observers. ECG-triggered HRCT by 0.5 s/rotation MDCT can reduce the cardiac motion artifact and is useful for evaluating the extent of ground-glass attenuation of IPF. (author)

  19. Detailed Opacity Calculations for Astrophysical Applications

    Directory of Open Access Journals (Sweden)

    Jean-Christophe Pain

    2017-05-01

    Full Text Available Nowadays, several opacity codes are able to provide data for stellar structure models, but the computed opacities may show significant differences. In this work, we present state-of-the-art precise spectral opacity calculations, illustrated by stellar applications. The essential role of laboratory experiments to check the quality of the computed data is underlined. We review some X-ray and XUV laser and Z-pinch photo-absorption measurements as well as X-ray emission spectroscopy experiments involving hot dense plasmas produced by ultra-high-intensity laser irradiation. The measured spectra are systematically compared with the fine-structure opacity code SCO-RCG. The focus is on iron, due to its crucial role in understanding asteroseismic observations of β Cephei-type and Slowly Pulsating B stars, as well as of the Sun. For instance, in β Cephei-type stars, the iron-group opacity peak excites acoustic modes through the “kappa-mechanism”. Particular attention is paid to the higher-than-predicted iron opacity measured at the Sandia Z-machine at solar interior conditions. We discuss some theoretical aspects such as density effects, photo-ionization, autoionization or the “filling-the-gap” effect of highly excited states.

  20. Seven-microRNA panel for lung adenocarcinoma early diagnosis in patients presenting with ground-glass nodules

    Directory of Open Access Journals (Sweden)

    He Y

    2017-12-01

    Full Text Available Yayi He,1,2,* Yang Yang,3,* Peng Kuang,1 Shengxiang Ren,1 Leslie Rozeboom,2 Christopher J Rivard,2 Xuefei Li,4 Caicun Zhou,1 Fred R Hirsch2 1Department of Medical Oncology, Shanghai Pulmonary Hospital, Tongji University Medical School Cancer Institute, Tongji University School of Medicine, Shanghai, People’s Republic of China; 2Division of Medical Oncology, Department of Medicine, University of Colorado Anschutz Medical Campus, Aurora, CO, USA; 3Department of Surgery, Shanghai Pulmonary Hospital, Tongji University Medical School Cancer Institute, Tongji University School of Medicine, 4Department of Lung Cancer and Immunology, Shanghai Pulmonary Hospital, Tongji University Medical School Cancer Institute, Tongji University School of Medicine, Shanghai, People’s Republic of China *These authors contributed equally to this work Background: MicroRNA (miRNA expression is correlated with tumor histology, differentiation, invasiveness and treatment outcome. We aimed to identify miRNAs whose differential expression might enable early diagnosis of lung adenocarcinoma in patients presenting with ground-glass nodules (GGNs.Methods: To identify potential miRNAs of interest, we analyzed the miRNA expression profile of tumor and adjacent non-para-tumor tissue in three participants by next-generation sequencing (NGS. We then assessed the expression levels of the miRNAs of interest in 73 lung adenocarcinomas presenting with GGNs with matched adjacent non-tumor tissue by quantitative real-time polymerase chain reaction (qRT-PCR. We also detected the miRNA panel in 66 lung benign diseases and 66 lung adenocarcinomas presenting with GGN lesion tissues by qRT-PCR. Target genes of our selected miRNA panel were predicted using Miranda with default parameters.Results: Twenty-three miRNAs showed differential expression between tumor and adjacent non-tumor tissue by NGS. Five miRNAs exhibited higher expression in tumor tissue compared to adjacent non-tumor tissue (P

  1. Application of positron emission tomography-computed tomography in the diagnosis of pulmonary ground-glass nodules.

    Science.gov (United States)

    Hu, Lili; Pan, Yuanwei; Zhou, Zhigang; Gao, Jianbo

    2017-11-01

    The aim of the present study was to investigate the value of positron emission tomography-computed tomography (PET-CT) using 18 F-fluorodeoxyglucose in the clinical diagnosis of pulmonary ground-glass nodule. In total, 54 patients with pulmonary GGN that were identified by PET-CT examination were selected and confirmed by pathology and clinical diagnosis in hospital between April 2014 and April 2015. The association between PET-CT findings and pathology, and the value of PET-CT were then evaluated. In the 54 patients, solitary pulmonary GGN with a nodule diameter of between 0.6 and 2.0 cm were detected. Amongst them, the PET-CT examination of 42 patients revealed hyper metabolic nodules, and were all mixed GGN type nodules with a diameter >1 cm. The PET-CT examination of the remaining 12 patients demonstrated no evidence of metabolic abnormalities and the nodules in these patients were pure or mixed GGN with a diameter <1 cm (except 2 cases with a diameter ≥1 cm). Furthermore, the diagnoses for all patients were pathologically confirmed by CT-guided needle biopsy or thoracoscopic surgical resection. Amongst them, there were 41 cases of lung adenocarcinoma, 4 cases of fungal infection, 7 cases of inflammation and 2 cases of adenomatoid hyperplasia. Additionally, PET-CT has a lower detection rate for smaller GGN exhibits no clear advantage for pure GGN, but has a higher detection rate for larger GGN. In conclusion, to a certain extent, PET-CT makes up for the shortcomings of traditional imaging and has some clinical value for the diagnosis of GGN.

  2. Heat transfer performance of the OPAC 106 heat exchanger; Warmte-overdrachtsprestaties van de OPAC106 warmtewisselaar

    Energy Technology Data Exchange (ETDEWEB)

    De Zwart, H.F.; Janssen, H.J.J. [Wageningen UR Glastuinbouw, Wageningen (Netherlands)

    2010-10-15

    The heat transfer performance of a new type compact heat exchanger were studied. It concerns the OPAC106, developed for the horticultural sector. The OPAC 106 combines a compact size with high heat transfer at low consumption of electricity for air circulation. OPAC stands for Oval Pipe Air Conditioner [Dutch] De warmte-overdrachtprestaties van een nieuw type compacte warmtewisselaar zijn bestudeerd. Het betreft de OPAC106, een speciaal voor de tuinbouw ontwikkelde warmtewisselaar. OPAC betekent Ovale Pijpen Air Conditioner.

  3. OPserver: opacities and radiative accelerations on demand

    Science.gov (United States)

    Mendoza, C.; González, J.; Seaton, M. J.; Buerger, P.; Bellorín, A.; Meléndez, M.; Rodríguez, L. S.; Delahaye, F.; Zeippen, C. J.; Palacios, E.; Pradhan, A. K.

    2009-05-01

    We report on developments carried out within the Opacity Project (OP) to upgrade atomic database services to comply with e-infrastructure requirements. We give a detailed description of an interactive, online server for astrophysical opacities, referred to as OPserver, to be used in sophisticated stellar modelling where Rosseland mean opacities and radiative accelerations are computed at every depth point and each evolution cycle. This is crucial, for instance, in chemically peculiar stars and in the exploitation of the new asteroseismological data. OPserver, downloadable with the new OPCD_3.0 release from the Centre de Données Astronomiques de Strasbourg, France, computes mean opacities and radiative data for arbitrary chemical mixtures from the OP monochromatic opacities. It is essentially a client-server network restructuring and optimization of the suite of codes included in the earlier OPCD_2.0 release. The server can be installed locally or, alternatively, accessed remotely from the Ohio Supercomputer Center, Columbus, Ohio, USA. The client is an interactive web page or a subroutine library that can be linked to the user code. The suitability of this scheme in grid computing environments is emphasized, and its extension to other atomic database services for astrophysical purposes is discussed.

  4. Ground glass hepatocytes provide targets for therapy or prevention of hepatitis B virus-related hepatocellular carcinoma

    Directory of Open Access Journals (Sweden)

    Hong-Yi Chang

    2018-03-01

    Full Text Available Ground glass hepatocyte (GGH represents a histologic hallmark of chronic hepatitis B virus (HBV infection and is characterized by the accumulation of pre-S mutant surface antigens in the endoplasmic reticulum (ER. In the past decade, GGHs have been recognized as pre-neoplastic lesions of hepatocellular carcinoma (HCC. The accumulation of pre-S mutant protein in ER may induce a misfolded protein response or ER stress signals with activation of VEGF/Akt/mTOR and COX-2/NF-κB signals, leading to oxidative DNA damage, aneuploidy, and genomic instability. Molecular studies revealed clonal HBV DNA integration in type II GGHs which continue to express and secrete surface antigens, representing the sustained surface antigens in the serum after NA antiviral treatment. The persistence of GGHs in the liver after anti-viral therapy not only constitute the challenge to eliminate HBV infection but also carry the high risk to develop HCC. DNA chip and ELISA kit are designing to detect the pre-S mutants in serum. Novel or second generation anti-HBV drugs are under phase II development and include the combination of anti-virals, immunomodulators, agents for host DNA damage, and siRNA to target at the transcription of HBsAg gene in cccDNA or integrated HBV DNA. In the past years, we explored the possibility to provide drugs or natural agents targeting at ER stress signals in GGHs to prevent HCC development. In a transgenic mice model of pre-S mutant and HBx, a combination of silymarin and resveratrol targeting at mTOR and NF-κB signals could reduce a 80% of HCC development. In a pilot clinical trial, liposomal curcumin (Meriva® combined with anti-virals and immumodulators P1101 have been designed and attempted to eliminate the serum surface antigen and hence the recurrence of HCC after surgical resection. Therefore, the detection of pre-S mutants in serum or GGHs in the liver should provide rational target design for therapy or prevention of HCC in these high

  5. The Rosseland mean opacity of interstellar grain

    International Nuclear Information System (INIS)

    Ali, A.; El Shalaby, M.A.; El-Nawawy, M.S.

    1990-10-01

    We have calculated the opacity of interstellar grains in the temperature range 10 deg. K - 1500 deg. K. Two composite grain models have been considered. One of them consists of silicate coated with ice mantle and the second has a graphite core coated also with ice mantle. These models are compared with isolated grain models. An exact analytical and computational development of Guettler's formulae for composite grain models has been used to calculate the extinction coefficient. It has been found that the thickness of the mantle affects the opacity of the interstellar grains. The opacity of composite models differs from that of the isolated models. The effect of the different species (ice, silicate and graphite) is also clear. (author). 22 refs, 4 figs, 1 tab

  6. Performance audit procedures for opacity monitors

    International Nuclear Information System (INIS)

    Plaisance, S.J.; Peeler, J.W.

    1987-04-01

    This manual contains monitor-specific performance audit procedures and data forms for use in conducting audits of installed opacity continuous emission monitoring systems (CEMS). General auditing procedures and acceptance limits for various audit criteria are discussed. Practical considerations and common problems encountered in conducting audits are delineated, and recommendations are included to optimize the successful completion of performance audits. Performance audit procedures and field-data forms were developed for six common opacity CEMS: (1) Lear Siegler, Inc. Model RM-41; (2) Lear Siegler, Inc. Model RM-4; (3) Dynatron Model 1100; (4) Thermo Electron, Inc. Model 400; (5) Thermo Electron, Inc. Model 1000A; and (6) Enviroplan Model D-R280 AV. Generic audit procedures are included for use in evaluating opacity CEMS with multiple transmissometers and combiner devices. In addition, several approaches for evaluating the zero-alignment or clear-path zero response are described. The zero-alignment procedures are included since the factor is fundamental to the accuracy of opacity monitoring data, even though the zero-alignment checks cannot usually be conducted during a performance audit

  7. Time Patterns in Remote OPAC Use.

    Science.gov (United States)

    Lucas, Thomas A.

    1993-01-01

    Describes a transaction log analysis of the New York Public Library research libraries' OPAC (online public access catalog). Much of the remote searching occurred when the libraries were closed and was more evenly distributed than internal searching, demonstrating that remote searching could expand access and reduce peak system loads. (Contains…

  8. Neutrino opacities and the pasta phase structure

    International Nuclear Information System (INIS)

    Menezes, D.P.; Alloy, M.D.

    2011-01-01

    The diffusion coefficients that are related to the neutrino opacities are calculated in such a way that the formation of nuclear pasta and homogeneous matter at low densities are taken into account. Two methods are developed to build the pasta phase and their differences are outlined. One of them is chosen as part of a complete equation of state used in the calculation of the diffusion coefficients. Our results show that the mean free paths are significantly altered by the presence of nuclear pasta in stellar matter when compared with the results obtained with pure homogeneous matter. These differences in neutrino opacities will have consequences in the calculation of the Kelvin-Helmholtz phase of protoneutron stars. (author)

  9. OPAC systému ALEPH

    OpenAIRE

    Pačísková, Jana

    2010-01-01

    This bachelor thesis presents analysis and evaluation of online catalog of integrated library system ALEPH, which was made after studying Web OPAC manual of this system and gathering information from practical testing of catalogs of National Library of Czech Republic and Regional Library of Karlovy Vary. In the first chapter, there is introduced and defined Online Public Access Catalog and its main principles and also its history is presented. In next chapters, there are described features an...

  10. Extended Opacity Tables with Higher Temperature-Density-Frequency Resolution

    Science.gov (United States)

    Schillaci, Mark; Orban, Chris; Delahaye, Franck; Pinsonneault, Marc; Nahar, Sultana; Pradhan, Anil

    2015-05-01

    Theoretical models for plasma opacities underpin our understanding of radiation transport in many different astrophysical objects. These opacity models are also relevant to HEDP experiments such as ignition scale experiments on NIF. We present a significantly expanded set of opacity data from the widely utilized Opacity Project, and make these higher resolution data publicly available through OSU's portal with dropbox.com. This expanded data set is used to assess how accurate the interpolation of opacity data in temperature-density-frequency dimensions must be in order to adequately model the properties of most stellar types. These efforts are the beginning of a larger project to improve the theoretical opacity models in light of experimental results at the Sandia Z-pinch showing that the measured opacity of Iron disagrees strongly with all current models.

  11. Revitalizing the Library OPAC: Interface, Searching, and Display Challenges

    Directory of Open Access Journals (Sweden)

    Jia Mi

    2008-03-01

    Full Text Available The behavior of academic library users has drastically changed in recent years. Internet search engines have become the preferred tool over the library online public access catalog (OPAC for finding information. Libraries are losing ground to online search engines. In this paper, two aspects of OPAC use are studied: (1 the current OPAC interface and searching capabilities, and (2 the OPAC bibliographic display. The purpose of the study is to find answers to the following questions: Why is the current OPAC ineffective? What can libraries and librarians do to deliver an OPAC that is as good as search engines to better serve our users? Revitalizing the library OPAC is one of the pressing issues that has to be accomplished.

  12. SOLAR OPACITY CALCULATIONS USING THE SUPER-TRANSITION-ARRAY METHOD

    International Nuclear Information System (INIS)

    Krief, M.; Feigel, A.; Gazit, D.

    2016-01-01

    A new opacity model has been developed based on the Super-Transition-Array (STA) method for the calculation of monochromatic opacities of plasmas in local thermodynamic equilibrium. The atomic code, named STAR (STA-Revised), is described and used to calculate spectral opacities for a solar model implementing the recent AGSS09 composition. Calculations are carried out throughout the solar radiative zone. The relative contributions of different chemical elements and atomic processes to the total Rosseland mean opacity are analyzed in detail. Monochromatic opacities and charge-state distributions are compared with the widely used Opacity Project (OP) code, for several elements near the radiation–convection interface. STAR Rosseland opacities for the solar mixture show a very good agreement with OP and the OPAL opacity code throughout the radiation zone. Finally, an explicit STA calculation was performed of the full AGSS09 photospheric mixture, including all heavy metals. It was shown that, due to their extremely low abundance, and despite being very good photon absorbers, the heavy elements do not affect the Rosseland opacity

  13. SOLAR OPACITY CALCULATIONS USING THE SUPER-TRANSITION-ARRAY METHOD

    Energy Technology Data Exchange (ETDEWEB)

    Krief, M.; Feigel, A.; Gazit, D., E-mail: menahem.krief@mail.huji.ac.il [The Racah Institute of Physics, The Hebrew University, 91904 Jerusalem (Israel)

    2016-04-10

    A new opacity model has been developed based on the Super-Transition-Array (STA) method for the calculation of monochromatic opacities of plasmas in local thermodynamic equilibrium. The atomic code, named STAR (STA-Revised), is described and used to calculate spectral opacities for a solar model implementing the recent AGSS09 composition. Calculations are carried out throughout the solar radiative zone. The relative contributions of different chemical elements and atomic processes to the total Rosseland mean opacity are analyzed in detail. Monochromatic opacities and charge-state distributions are compared with the widely used Opacity Project (OP) code, for several elements near the radiation–convection interface. STAR Rosseland opacities for the solar mixture show a very good agreement with OP and the OPAL opacity code throughout the radiation zone. Finally, an explicit STA calculation was performed of the full AGSS09 photospheric mixture, including all heavy metals. It was shown that, due to their extremely low abundance, and despite being very good photon absorbers, the heavy elements do not affect the Rosseland opacity.

  14. Radiologic Predictors for Clinical Stage IA Lung Adenocarcinoma with Ground Glass Components: A Multi-Center Study of Long-Term Outcomes.

    Directory of Open Access Journals (Sweden)

    Zhao Li

    Full Text Available This study was to define preoperative predictors from radiologic findings for the pathologic risk groups based on long-term surgical outcomes, in the aim to help guide individualized patient management.We retrospectively reviewed 321 consecutive patients with clinical stage IA lung adenocarcinoma with ground glass component on computed tomography (CT scanning. Pathologic diagnosis for resection specimens was based on the 2011 IASLC/ATS/ERS classification of lung adenocarcinoma. Patients were classified into different pathologic risk grading groups based on their lymph node status, local regional recurrence and overall survival. Radiologic characteristics of the pulmonary nodules were re-evaluated by reconstructed three-dimension CT (3D-CT. Univariate and multivariate analysis identifies independent radiologic predictors from tumor diameter, total volume (TV, average CT value (AVG, and solid-to-tumor (S/T ratio. Receiver operating characteristic curves (ROC studies were carried out to determine the cutoff value(s for the predictor(s. Univariate cox regression model was used to determine the clinical significance of the above findings.A total of 321 patients with clinical stage IA lung adenocarcinoma with ground glass components were included in our study. Patients were classified into two pathologic low- and high- risk groups based on their distinguished surgical outcomes. A total of 134 patients fell into the low-risk group. Univariate and multivariate analyses identified AVG (HR: 32.210, 95% CI: 3.020-79.689, P<0.001 and S/T ratio (HR: 12.212, 95% CI: 5.441-27.408, P<0.001 as independent predictors for pathologic risk grading. ROC curves studies suggested the optimal cut-off values for AVG and S/T ratio were-198 (area under the curve [AUC] 0.921, 2.9 (AUC 0.996 and 54% (AUC 0.907, respectively. The tumor diameter and TV were excluded for the low AUCs (0.778 and 0.767. Both the cutoff values of AVG and S/T ratio were correlated with pathologic

  15. INTERPLAY OF NEUTRINO OPACITIES IN CORE-COLLAPSE SUPERNOVA SIMULATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Lentz, Eric J. [Department of Physics and Astronomy, University of Tennessee, Knoxville, TN 37996-1200 (United States); Mezzacappa, Anthony; Hix, W. Raphael [Physics Division, Oak Ridge National Laboratory, P.O. Box 2008, Oak Ridge, TN 37831-6354 (United States); Messer, O. E. Bronson [National Center for Computational Sciences, Oak Ridge National Laboratory, P.O. Box 2008, Oak Ridge, TN 37831-6164 (United States); Bruenn, Stephen W., E-mail: elentz@utk.edu [Department of Physics, Florida Atlantic University, 777 Glades Road, Boca Raton, FL 33431-0991 (United States)

    2012-11-20

    We have conducted a series of numerical experiments using spherically symmetric, general relativistic, neutrino radiation hydrodynamics with the code Agile-BOLTZTRAN to examine the effects of modern neutrino opacities on the development of supernova simulations. We test the effects of opacities by removing opacities or by undoing opacity improvements for individual opacities and groups of opacities. We find that improvements to electron capture (EC) on nuclei, namely EC on an ensemble of nuclei using modern nuclear structure models rather than the simpler independent-particle approximation (IPA) for EC on a mean nucleus, plays the most important role during core collapse of all tested neutrino opacities. Low-energy neutrinos emitted by modern nuclear EC preferentially escape during collapse without the energy downscattering on electrons required to enhance neutrino escape and deleptonization for the models with IPA nuclear EC. During shock breakout the primary influence on the emergent neutrinos arises from non-isoenergetic scattering (NIS) on electrons. For the accretion phase, NIS on free nucleons and pair emission by e {sup +} e {sup -} annihilation have the largest impact on the neutrino emission and shock evolution. Other opacities evaluated, including nucleon-nucleon bremsstrahlung and especially neutrino-positron scattering, have little measurable impact on neutrino emission or shock dynamics. Modern treatments of nuclear EC, e {sup +} e {sup -}-annihilation pair emission, and NIS on electrons and free nucleons are critical elements of core-collapse simulations of all dimensionality.

  16. IPOPv2 online service for the generation of opacity tables

    International Nuclear Information System (INIS)

    Delahaye, Franck; Zwölf, Carlo Maria; Zeippen, Claude J.; Mendoza, Claudio

    2016-01-01

    In the framework of the present phase – IPOPv2 – of the international Opacity Project (OP), a new web service has been implemented based on the latest release of the OP opacities. The user may construct online opacity tables to be conveniently included in stellar evolution codes in the format most commonly adopted by stellar physicists, namely the OPAL format. This facility encourages the use and comparison of both the OPAL and OP data sets in applications. The present service allows for the calculation of multi-element mixtures containing the 17 species (H, He, C, N, O, Ne, Na, Mg, Al, Si, S, Ar, Ca, Cr, Mn, Fe and Ni) considered by the OP, and underpins the latest release of OP opacities. This new service provides tables of Rosseland mean opacites using OP atomic data. We provide an alternative to the OPAL opacity services allowing direct comparison as well as study of the effect of uncertainties in stellar modeling due to mean opacities. - Highlights: • A new opacity table service is presented. • This is an alternative to the OPAL service, using The Opacity Project (OP) data. • These tables can directly replace the OPAL data in stellar code without any change in the code.

  17. Dialogue with an OPAC: How Visionary Was Swanson in 1964?

    Science.gov (United States)

    Su, Shiao-Feng

    1994-01-01

    Traces the development of online public access catalogs (OPACs) and compares what has occurred with a 1964 article that outlined recommendations for a future card catalog. Subject access is emphasized, including Library of Congress Subject Headings, expansion of OPACs, user-friendly interfaces, new technologies, and current visions of the future…

  18. An Evaluation of Online Help for the NOTIS OPAC.

    Science.gov (United States)

    White, Frank

    1994-01-01

    Discussion of online help systems in online public access catalogs (OPACs) focuses on a study that evaluated the online help system for the NOTIS (Northwestern Online Total Integrated System) OPAC. Features of the system reviewed include online functions; training features; general interface features; access points; and message content and display…

  19. Calculation of Free-Free Opacities

    Science.gov (United States)

    Bhatia, A. K.; Maiden, D.; Ritchie, A. B., Jr.

    2003-01-01

    Free-free absorption is an important contribution to the opacity for radiation transport through hot materials Temperatures can be as high as several keV, such that it becomes a computational challenge to solve the Schrodinger equation efficiently for rapidly oscillating continuum functions for high angular momenta. Several groups\\footnots, including ours, have studied the phase amplitude solution (PAS) of the Schrodinger equation, in which one solves equations for the wave function amplitude and phase, which are: smooth functions of the electron energy. It is also important to have an accurate Schroudinger benchmark for the development of the PAS method. We present results for dipole matrix elements, Gaunt factors, and cross sections for the absorption of radiation at various energies for Cs XIX at temperature=100 eV and density=0.187 g/cc for our newly developed PAS and Schrodinger benchmark.

  20. An opacity-sampled treatment of water vapor

    Science.gov (United States)

    Alexander, David R.; Augason, Gordon C.; Johnson, Hollis R.

    1989-01-01

    Although the bands of H2O are strong in the spectra of cool stars and calculations have repeatedly demonstrated their significance as opacity sources, only approximate opacities are currently available, due both to the difficulty of accounting for the millions of lines involved and to the inadequacy of laboratory and theoretical data. To overcome these obstacles, a new treatment is presented, based upon a statistical representation of the water vapor spectrum derived from available laboratory data. This statistical spectrum of water vapor employs an exponential distribution of line strengths and random positions of lines whose overall properties are forced to reproduce the mean opacities observed in the laboratory. The resultant data set is then treated by the opacity-sampling method exactly as are all other lines, both molecular and atomic. Significant differences are found between the results of this improved treatment and the results obtained with previous treatments of water-vapor opacity.

  1. CT-guided needle biopsy in the diagnosis of lung adenocarcinoma accompanied by extranodal marginal zone lymphoma of mucosa-associated lymphoid tissue: a rare combination.

    Science.gov (United States)

    Tian, Panwen; Wang, Ye; Wan, Chun; Shen, Yongchun; Wen, Fuqiang

    2015-01-01

    We represent a rare case of lung adenocarcinoma accompanied by extranodal marginal zone lymphoma of mucosa-associated lymphoid tissue (MALT). The patient was a 66-year-old male presented with 1 month history of recurrent cough and hemoptysis. Chest CT showed solitary ground-glass opacity (GGO) in the upper lobe of the right lung and mediastinal lymph node enlargement in station 3p. A CT-guided transthoracic needle biopsy was performed. Tissue specimens of the GGO revealed a typical adenocarcinoma. Histopathologic diagnosis of mediastinal lymph node was extranodal marginal zone lymphoma of MALT. Because of its rarity, extranodal marginal zone lymphoma of MALT should be considered in the differential diagnosis when we encounter mediastinal lymphadenopathy in patients with lung adenocarcinoma.

  2. High-resolution computed tomography to differentiate chronic diffuse interstitial lung diseases with predominant ground-glass pattern using logical analysis of data

    International Nuclear Information System (INIS)

    Martin, Sophie Grivaud; Brauner, Michel W.; Rety, Frederique; Kronek, Louis-Philippe; Brauner, Nadia; Valeyre, Dominique; Nunes, Hilario; Brillet, Pierre-Yves

    2010-01-01

    We evaluated the performance of high-resolution computed tomography (HRCT) to differentiate chronic diffuse interstitial lung diseases (CDILD) with predominant ground-glass pattern by using logical analysis of data (LAD). A total of 162 patients were classified into seven categories: sarcoidosis (n = 38), connective tissue disease (n = 32), hypersensitivity pneumonitis (n = 18), drug-induced lung disease (n = 15), alveolar proteinosis (n = 12), idiopathic non-specific interstitial pneumonia (n = 10) and miscellaneous (n = 37). First, 40 CT attributes were investigated by the LAD to build up patterns characterising a category. From the association of patterns, LAD determined models specific to each CDILD. Second, data were recomputed by adding eight clinical attributes to the analysis. The 20 x 5 cross-folding method was used for validation. Models could be individualised for sarcoidosis, hypersensitivity pneumonitis, connective tissue disease and alveolar proteinosis. An additional model was individualised for drug-induced lung disease by adding clinical data. No model was demonstrated for idiopathic non-specific interstitial pneumonia and the miscellaneous category. The results showed that HRCT had a good sensitivity (≥64%) and specificity (≥78%) and a high negative predictive value (≥93%) for diseases with a model. Higher sensitivity (≥78%) and specificity (≥89%) were achieved by adding clinical data. The diagnostic performance of HRCT is high and can be increased by adding clinical data. (orig.)

  3. Ground-glass nodule on thin-section CT: Differentiation among adenocarcinoma in situ, minimally invasive adenocarcinoma and lepidic predominant invasive adenocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Man Ho; Ryu, Dae Shick; Kim, Do Young; Ahn, Jae Hong; Choi, Soo Jung; Gang, Gil Hyeon; Yoo, Dong Gon; Shin, Dong Rock [Gangneung Asan Hospital, College of Medicine, University of Ulsan, Gangneung (Korea, Republic of)

    2015-12-15

    To investigate different computed tomography (CT) features among adenocarcinoma in situ (AIS), minimally invasive adenocarcinoma (MIA), and lepidic predominant invasive adenocarcinoma (LPA) that appeared as ground-glass nodules (GGN). We also analyzed different CT findings between Group A (AIS and MIA) and Group B (LPA). We evaluated 19 AIS, 4 MIA, and 9 LPA images that were histologically confirmed and manifested as GGN on thin-section CT scans. CT scans were assessed for lesion characteristics: size, shape, solid portion, internal air density, marginal irregularity and pleural tag. CT findings of Group A and Group B were analyzed using the Kruskal-Wallis test or Fisher's exact test. A significant statistical difference was seen between AIS and LPA for lesion characteristics (p < 0.05). No significant difference was observed between AIS and MIA. Round or polygonal shape with smooth margin was significantly associated with Group A, and complex shape with marginal irregularity was associated with Group B. Group A (AIS and MIA) could be distinguished from Group B (LPA) by smaller lesion size, round or polygonal shape, smaller solid portion and smooth margin.

  4. Ground-glass nodule on thin-section CT: Differentiation among adenocarcinoma in situ, minimally invasive adenocarcinoma and lepidic predominant invasive adenocarcinoma

    International Nuclear Information System (INIS)

    Lee, Man Ho; Ryu, Dae Shick; Kim, Do Young; Ahn, Jae Hong; Choi, Soo Jung; Gang, Gil Hyeon; Yoo, Dong Gon; Shin, Dong Rock

    2015-01-01

    To investigate different computed tomography (CT) features among adenocarcinoma in situ (AIS), minimally invasive adenocarcinoma (MIA), and lepidic predominant invasive adenocarcinoma (LPA) that appeared as ground-glass nodules (GGN). We also analyzed different CT findings between Group A (AIS and MIA) and Group B (LPA). We evaluated 19 AIS, 4 MIA, and 9 LPA images that were histologically confirmed and manifested as GGN on thin-section CT scans. CT scans were assessed for lesion characteristics: size, shape, solid portion, internal air density, marginal irregularity and pleural tag. CT findings of Group A and Group B were analyzed using the Kruskal-Wallis test or Fisher's exact test. A significant statistical difference was seen between AIS and LPA for lesion characteristics (p < 0.05). No significant difference was observed between AIS and MIA. Round or polygonal shape with smooth margin was significantly associated with Group A, and complex shape with marginal irregularity was associated with Group B. Group A (AIS and MIA) could be distinguished from Group B (LPA) by smaller lesion size, round or polygonal shape, smaller solid portion and smooth margin

  5. A Comparison of Two Commercial Volumetry Software Programs in the Analysis of Pulmonary Ground-Glass Nodules: Segmentation Capability and Measurement Accuracy

    Science.gov (United States)

    Kim, Hyungjin; Lee, Sang Min; Lee, Hyun-Ju; Goo, Jin Mo

    2013-01-01

    Objective To compare the segmentation capability of the 2 currently available commercial volumetry software programs with specific segmentation algorithms for pulmonary ground-glass nodules (GGNs) and to assess their measurement accuracy. Materials and Methods In this study, 55 patients with 66 GGNs underwent unenhanced low-dose CT. GGN segmentation was performed by using 2 volumetry software programs (LungCARE, Siemens Healthcare; LungVCAR, GE Healthcare). Successful nodule segmentation was assessed visually and morphologic features of GGNs were evaluated to determine factors affecting segmentation by both types of software. In addition, the measurement accuracy of the software programs was investigated by using an anthropomorphic chest phantom containing simulated GGNs. Results The successful nodule segmentation rate was significantly higher in LungCARE (90.9%) than in LungVCAR (72.7%) (p = 0.012). Vascular attachment was a negatively influencing morphologic feature of nodule segmentation for both software programs. As for measurement accuracy, mean relative volume measurement errors in nodules ≥ 10 mm were 14.89% with LungCARE and 19.96% with LungVCAR. The mean relative attenuation measurement errors in nodules ≥ 10 mm were 3.03% with LungCARE and 5.12% with LungVCAR. Conclusion LungCARE shows significantly higher segmentation success rates than LungVCAR. Measurement accuracy of volume and attenuation of GGNs is acceptable in GGNs ≥ 10 mm by both software programs. PMID:23901328

  6. A comparison of two commercial volumetry software programs in the analysis of pulmonary ground-glass nodules: Segmentation capability and measurement accuracy

    International Nuclear Information System (INIS)

    Kim, Hyung Jin; Park, Chang Min; Lee, Sang Min; Lee, Hyun Joo; Goo, Jin Mo

    2013-01-01

    To compare the segmentation capability of the 2 currently available commercial volumetry software programs with specific segmentation algorithms for pulmonary ground-glass nodules (GGNs) and to assess their measurement accuracy. In this study, 55 patients with 66 GGNs underwent unenhanced low-dose CT. GGN segmentation was performed by using 2 volumetry software programs (LungCARE, Siemens Healthcare; LungVCAR, GE Healthcare). Successful nodule segmentation was assessed visually and morphologic features of GGNs were evaluated to determine factors affecting segmentation by both types of software. In addition, the measurement accuracy of the software programs was investigated by using an anthropomorphic chest phantom containing simulated GGNs. The successful nodule segmentation rate was significantly higher in LungCARE (90.9%) than in LungVCAR (72.7%) (p = 0.012). Vascular attachment was a negatively influencing morphologic feature of nodule segmentation for both software programs. As for measurement accuracy, mean relative volume measurement errors in nodules ≥ 10 mm were 14.89% with LungCARE and 19.96% with LungVCAR. The mean relative attenuation measurement errors in nodules ≥ 10 mm were 3.03% with LungCARE and 5.12% with LungVCAR. LungCARE shows significantly higher segmentation success rates than LungVCAR. Measurement accuracy of volume and attenuation of GGNs is acceptable in GGNs ≥ 10 mm by both software programs.

  7. A comparison of two commercial volumetry software programs in the analysis of pulmonary ground-glass nodules: Segmentation capability and measurement accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyung Jin; Park, Chang Min; Lee, Sang Min; Lee, Hyun Joo; Goo, Jin Mo [Dept. of Radiology, Seoul National University College of Medicine, and Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul (Korea, Republic of)

    2013-08-15

    To compare the segmentation capability of the 2 currently available commercial volumetry software programs with specific segmentation algorithms for pulmonary ground-glass nodules (GGNs) and to assess their measurement accuracy. In this study, 55 patients with 66 GGNs underwent unenhanced low-dose CT. GGN segmentation was performed by using 2 volumetry software programs (LungCARE, Siemens Healthcare; LungVCAR, GE Healthcare). Successful nodule segmentation was assessed visually and morphologic features of GGNs were evaluated to determine factors affecting segmentation by both types of software. In addition, the measurement accuracy of the software programs was investigated by using an anthropomorphic chest phantom containing simulated GGNs. The successful nodule segmentation rate was significantly higher in LungCARE (90.9%) than in LungVCAR (72.7%) (p = 0.012). Vascular attachment was a negatively influencing morphologic feature of nodule segmentation for both software programs. As for measurement accuracy, mean relative volume measurement errors in nodules ≥ 10 mm were 14.89% with LungCARE and 19.96% with LungVCAR. The mean relative attenuation measurement errors in nodules ≥ 10 mm were 3.03% with LungCARE and 5.12% with LungVCAR. LungCARE shows significantly higher segmentation success rates than LungVCAR. Measurement accuracy of volume and attenuation of GGNs is acceptable in GGNs ≥ 10 mm by both software programs.

  8. Impact of Neutrino Opacities on Core-collapse Supernova Simulations

    Science.gov (United States)

    Kotake, Kei; Takiwaki, Tomoya; Fischer, Tobias; Nakamura, Ko; Martínez-Pinedo, Gabriel

    2018-02-01

    The accurate description of neutrino opacities is central to both the core-collapse supernova (CCSN) phenomenon and the validity of the explosion mechanism itself. In this work, we study in a systematic fashion the role of a variety of well-selected neutrino opacities in CCSN simulations where the multi-energy, three-flavor neutrino transport is solved using the isotropic diffusion source approximation (IDSA) scheme. To verify our code, we first present results from one-dimensional (1D) simulations following the core collapse, bounce, and ∼250 ms postbounce of a 15 {M}ȯ star using a standard set of neutrino opacities by Bruenn. A detailed comparison with published results supports the reliability of our three-flavor IDSA scheme using the standard opacity set. We then investigate in 1D simulations how individual opacity updates lead to differences with the baseline run with the standard opacity set. Through detailed comparisons with previous work, we check the validity of our implementation of each update in a step-by-step manner. Individual neutrino opacities with the largest impact on the overall evolution in 1D simulations are selected for systematic comparisons in our two-dimensional (2D) simulations. Special attention is given to the criterion of explodability in the 2D models. We discuss the implications of these results as well as its limitations and the requirements for future, more elaborate CCSN modeling.

  9. HELIOSEISMIC TESTS OF THE NEW LOS ALAMOS OPACITIES

    Energy Technology Data Exchange (ETDEWEB)

    J. GUZIK; ET AL

    2001-01-01

    We compare the helioseismic properties of two solar models, one calibrated with the OPAL opacities and the other with the recent Los Alamos LEDCOP opacities. We show that, in the radiative interior of the Sun, the small differences between the two sets of opacities (up to 6% near the base of the convection zone) lead to noticeable differences in the solar structure (up to 0.4% in sound speed), with the OPAL model being the closest to the helioseismic data. More than half of the difference between the two opacity sets results from the interpolation scheme and from the relatively widely spaced temperature grids used in the tables. The remaining 3% intrinsic difference between the OPAL and the LEDCOP opacities in the radiative interior of the Sun is well within the error bars on the opacity calculations resulting from the uncertainties on the physics. We conclude that the OPAL and LEDCOP opacity sets do about as well in the radiative interior of the Sun.

  10. The Rosseland Mean Opacity in Dense Plasmas

    Science.gov (United States)

    van Horn, H. M.

    1992-05-01

    In post-main-sequence phases of stellar evolution, densities in the interiors of stars become large enough so that hbar omega_p /kT>1, where omega_p is the electron plasma frequency. The plasma is thus a strongly dispersive medium at frequencies near the peak of the Planck function, and only photons with frequencies omega >omega_p can propagate in the plasma. These effects must be taken into account in computing radiative transfer in stellar interiors. Here I first identify several late evolutionary stages in which these effects may be significant. Then I use the formalism Harris 1965 has developed to treat radiative transfer in a dispersive medium in order to derive the resulting modification of the Rosseland mean opacity kappa_R . The resulting expression is the same as that presented (without a full derivation) by Aharony & Opher 1979, who interpreted the frequency-dependent absorption coefficient kappa_ ω as that in vacuo. However, the absorption coefficient in a plasma scales from that in vacuum according to the relation kappa_ ω=n_ω(-1) kappa_ ω((vac)) (Bekefi 1966, p. 52), where n_ω equiv (kc/omega ) = [1-(omega_p (2/) omega (2)right ](1/2)) is the index of refraction of the plasma. With this correction, we find the Rosseland mean opacity to be given by the expression {1\\over \\kappa_R}={{\\int_{\\omega_p}^{\\infty} {n_{\\omega}^3 \\over \\kappa_{\\omega}^{(vac)}}{partial B_{\\omega} \\over partial T} \\bigg|_{\\omega} d\\omega} \\over{\\int_0^{\\infty}{partial B_{\\omega} \\over partial T} \\bigg|_{\\omega} d\\omega}}. This research has been supported in part by NASA grant NAGW-2444 and in part by NSF grant AST 91-15132. \\centerline{References} Aharony, U., and Opher, R. 1979, A&A, 79, 27. Bekefi, G. 1966, Radiation Processes in Plasmas, (John Wiley & Sons, Inc.: New York). Harris, E. G. 1965, Phys. Rev., 138, B479.

  11. Effective Opacity for Gold-Doped Foam Plasmas

    International Nuclear Information System (INIS)

    Huang Cheng-Wu; Song Tian-Ming; Zhao Yang; Zhu Tuo; Shang Wan-Li; Xiong Gang; Zhang Ji-Yan; Yang Jia-Min; Jiang Shao-En

    2012-01-01

    Radiation flow through gold-doped hydrocarbon foam is investigated and a model is presented to calculate effective opacity for an inhomogeneous, pressure-equilibrated gold/foam mixture based on the Levermore—Pomraning method for binary stochastic media. The effective opacity dependance on the size of the gold particles and the foam temperature are studied. The results suggest that when the mixture temperature is lower than 250 eV, the opacity difference between the 5 μm particle mix case and the atomic mix case is large enough to induce a significant discrepancy in radiation transport, which is confirmed by the hydrodynamic simulation

  12. Computing NLTE Opacities -- Node Level Parallel Calculation

    Energy Technology Data Exchange (ETDEWEB)

    Holladay, Daniel [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-09-11

    Presentation. The goal: to produce a robust library capable of computing reasonably accurate opacities inline with the assumption of LTE relaxed (non-LTE). Near term: demonstrate acceleration of non-LTE opacity computation. Far term (if funded): connect to application codes with in-line capability and compute opacities. Study science problems. Use efficient algorithms that expose many levels of parallelism and utilize good memory access patterns for use on advanced architectures. Portability to multiple types of hardware including multicore processors, manycore processors such as KNL, GPUs, etc. Easily coupled to radiation hydrodynamics and thermal radiative transfer codes.

  13. Research on Spectroscopy, Opacity, and Atmospheres

    Science.gov (United States)

    Kurucz, Robert L.

    2005-01-01

    I propose to continue providing observers with basic data for interpreting spectra from stars, novas, supernovas, clusters, and galaxies. These data will include allowed and forbidden line lists, both laboratory and computed, for the first five to ten ions of all atoms and for all relevant diatomic molecules. I will eventually expand to all ions of the first thirty elements to treat far UV and X-ray spectra, and for envelope opacities. I also include triatomic molecules provided by other researchers. I have also made CDs with Partridge and Schwenke's water data for work on UV stars. The line data also serve as input to my model atmosphere and synthesis programs that generate energy distributions, photometry, limb darkening, and spectra that can be used for planning observations and for fitting observed spectra. The spectrum synthesis programs produce detailed plots with the lines identified. Grids of stellar spectra can be used for radial velocity-, rotation-, or abundance templates and for population synthesis. I am fitting spectra of bright stars to test the data and to produce atlases to guide observers. For each star the whole spectrum is computed from the UV to the far IR. The line data, opacities, models, spectra, and programs are freely distributed on CDs and on my Web site and represent a unique resource for many NASA programs. I am now in full production of new line lists for atoms. I am computing all ions of all elements from H to Zn and the first 5 ions of all the heavier elements, about 800 ions. For each ion I treat as many as 61 even and 61 odd configurations, computing all energy levels and eigenvectors. The Hamiltonian is determined from a scaled-Hartree-Fock starting guess by least squares fitting the observed energy levels. The average energy of each configuration is used in computing scaled-Thomas-Fermi-Dirac wavefunctions for each configuration which in turn are used to compute allowed and forbidden transition integrals. These are multiplied

  14. Opacity calculations for laser plasma applications

    International Nuclear Information System (INIS)

    Magee, N.H. Jr.

    1986-01-01

    The Los Alamos LTE light element detailed configuration opacity code (LEDCOP) has been revised to provide more accurate absorption coefficients and group means for modern radiation-hydrodynamic codes. The new group means will be especially useful for computing the transport of thermal radiation from laser deposition. The principal improvement is the inclusion of a complete set of accurate and internally consistent LS term energies and oscillator strengths in both the EOS and absorption coefficients. Selected energies and oscillator strengths were calculated from a Hartree-Fock code, then fitted by a quantum defect method. This allowed transitions at all wavelengths to be treated consistently and accurately instead of being limited to wavelength regions covered by experimental observations or isolated theoretical calculations. A second improvement is the use of more accurate photoionization cross sections for excited as well as ground state configurations. These cross sections are now more consistent with the bound-bound oscillator strengths, leading to a smooth transition across the continuum limit. Results will be presented showing the agreement of the LS term energies and oscillator strengths with observed values. The new absorption coefficients will be compared with previous calculations. 5 refs., 9 figs., 1 tab

  15. Exome Array Analysis of Nuclear Lens Opacity.

    Science.gov (United States)

    Loomis, Stephanie J; Klein, Alison P; Lee, Kristine E; Chen, Fei; Bomotti, Samantha; Truitt, Barbara; Iyengar, Sudha K; Klein, Ronald; Klein, Barbara E K; Duggal, Priya

    2018-06-01

    Nuclear cataract is the most common subtype of age-related cataract, the leading cause of blindness worldwide. It results from advanced nuclear sclerosis, or opacity in the center of the optic lens, and is affected by both genetic and environmental risk factors, including smoking. We sought to understand the genetic factors associated with nuclear sclerosis through interrogation of rare and low frequency coding variants using exome array data. We analyzed Illumina Human Exome Array data for 1,488 participants of European ancestry in the Beaver Dam Eye Study who were without cataract surgery for association with nuclear sclerosis grade, controlling for age and sex. We performed single-variant regression analysis for 32,138 variants with minor allele frequency (MAF) ≥0.003. In addition, gene-based analysis of 11,844 genes containing at least two variants with MAF nuclear sclerosis, the possible association with the RNF149 gene highlights a potential candidate gene for future studies that aim to understand the genetic architecture of nuclear sclerosis.

  16. Comparative pulsation calculations with OP and OPAL opacities

    Science.gov (United States)

    Kanbur, Shashi M.; Simon, Norman R.

    1994-01-01

    Comparative linear nonadiabatic pulsation calculations are presented using the OPAL and Opacity Project opacities. The two sets of opacities include effects due to intermediate coupling and fine structure as well as new abundances. We used two mass luminosity (M-L) relations, one standard (BIT), and one employing substantial convective core overshoot (COV). The two sets of opacities cannot be differentiated on the basis of the stellar pulsation calculations presented here. The BIT relation can model the beat and bump Cepheids with masses between 4 and 7 solar mass, while if the overshoot relation is used, masses between 2 and 6 solar mass are required. In the RR Lyrae regime, we find the inferred masses of globular cluster RRd stars to be little influenced by the choice of OPAL or OP. Finally, the limited modeling we have done is not able to constrain the Cepheid M-L relation based upon period ratios observed in the beat and bump stars.

  17. Humidifier disinfectant-associated children's interstitial lung disease: Computed tomographic features, histopathologic correlation and comparison between survivors and non-survivors

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Hee Mang; Lee, Jin Seong; Do, Kyung-Hyun; Jung, Ah Young; Yoon, Chong Hyun; Cho, Young Ah [Asan Medical Center, University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Songpa-gu, Seoul (Korea, Republic of); Lee, Eun; Hong, Soo-Jong [Asan Medical Center, University of Ulsan College of Medicine, Department of Pediatrics, Songpa-gu, Seoul (Korea, Republic of); Kim, Seon-Ok [Asan Medical Center, University of Ulsan College of Medicine, Department of Clinical Epidemiology and Biostatistics, Songpa-gu, Seoul (Korea, Republic of); Jang, Se-Jin [Asan Medical Center, University of Ulsan College of Medicine, Departments of Pathology, Songpa-gu, Seoul (Korea, Republic of)

    2016-01-15

    To report radiologic findings with histopathologic correlations of humidifier disinfectant-associated children's interstitial lung disease (HD-chILD) and to compare computed tomography (CT) findings between survivors and non-survivors. Forty-seven children with HD-chILD (27.4 ± 12.4 months old) were categorized as survivors (n = 25) and non-survivors (n = 22). The patterns, distributions, and chronological changes in lung lesions at follow-up CT were investigated. Histopathologic correlations were performed in 23 patients. CT features were characterized by chronological changes, from consolidation to centrilobular opacities, and lesions eventually became faint centrilobular nodules. Histopathologic features were bronchocentric-distributed fibro-inflammatory lesions, which were more profound in the advanced stage than the early stage. Consolidation ≥30 % [hazard ratio (HR), 2.932], centrilobular opacities ≥60 % of the total lung volume (TLV; HR, 0.206) and spontaneous air leaks (HR, 3.457) were significant factors associated with patient survival, as per univariate analysis. Consolidation ≥30 % (HR, 3.519), centrilobular opacities ≥60 % (HR, 0.205) and diffuse ground glass opacity (GGO) ≥70 % of the TLV (HR, 3.521) were significant factors associated with patient survival, as determined via multivariate analysis. Distinctive chronological CT features were observed in the HD-chILD images. Spontaneous air leaks, consolidation, GGO, and centrilobular opacities were prognostic factors. (orig.)

  18. Opacity calculations for extreme physical systems: code RACHEL

    Science.gov (United States)

    Drska, Ladislav; Sinor, Milan

    1996-08-01

    Computer simulations of physical systems under extreme conditions (high density, temperature, etc.) require the availability of extensive sets of atomic data. This paper presents basic information on a self-consistent approach to calculations of radiative opacity, one of the key characteristics of such systems. After a short explanation of general concepts of the atomic physics of extreme systems, the structure of the opacity code RACHEL is discussed and some of its applications are presented.

  19. Nuclear 'pasta phase' and its consequences on neutrino opacities

    International Nuclear Information System (INIS)

    Alloy, M. D.; Menezes, D. P.

    2011-01-01

    In this paper, we calculate the diffusion coefficients that are related to the neutrino opacities considering the formation of nuclear pasta and homogeneous matter at low densities. Our results show that the mean-free paths are significantly altered by the presence of nuclear pasta in stellar matter when compared with the results obtained with homogeneous matter. These differences in neutrino opacities certainly influence the Kelvin-Helmholtz phase of protoneutron stars and consequently the results of supernova explosion simulations.

  20. Solar opacities constrained by solar neutrinos and solar oscillations

    International Nuclear Information System (INIS)

    Cox, A.N.

    1989-01-01

    This review discusses the current situation for opacities at the solar center, the solar surface, and for the few million kelvin temperatures that occur below the convection zone. The solar center conditions are important because they are crucial for the neutrino production, which continues to be predicted about 4 times that observed. The main extinction effects there are free-free photon absorption in the electric fields of the hydrogen, helium and the CNO atoms, free electron scattering of photons, and the bound-free and bound-bound absorption of photons by iron atoms with two electrons in the 1s bound level. An assumption that the iron is condensed-out below the convection zone, and the opacity in the central regions is thereby reduced, results in about a 25 percent reduction in the central opacity but only a 5 percent reduction at the base of the convection zone. Furthermore, the p-mode solar oscillations are changed with this assumption, and do not fit the observed ones as well as for standard models. A discussion of the large effective opacity reduction by weakly interacting massive particles also results in poor agreement with observed p-mode oscillation frequencies. The much larger opacities for the solar surface layers from the Los Alamos Astrophysical Opacity Library instead of the widely used Cox and Tabor values show small improvements in oscillation frequency predictions, but the largest effect is in the discussion of p-mode stability. Solar oscillation frequencies can serve as an opacity experiment for the temperatures and densities, respectively, of a few million kelvin and between 0.1 and 10 g/cm 3 . Current oscillation frequency calculations indicate that possibly the Opacity Library values need an increase of typically 15 percent just at the bottom of the convection zone at 3 x 10 6 K. 41 refs., 15 figs., 1 tab

  1. Investigating the Effect of Cosmic Opacity on Standard Candles

    International Nuclear Information System (INIS)

    Hu, J.; Yu, H.; Wang, F. Y.

    2017-01-01

    Standard candles can probe the evolution of dark energy over a large redshift range. But the cosmic opacity can degrade the quality of standard candles. In this paper, we use the latest observations, including Type Ia supernovae (SNe Ia) from the “joint light-curve analysis” sample and Hubble parameters, to probe the opacity of the universe. A joint fitting of the SNe Ia light-curve parameters, cosmological parameters, and opacity is used in order to avoid the cosmological dependence of SNe Ia luminosity distances. The latest gamma-ray bursts are used in order to explore the cosmic opacity at high redshifts. The cosmic reionization process is considered at high redshifts. We find that the sample supports an almost transparent universe for flat ΛCDM and XCDM models. Meanwhile, free electrons deplete photons from standard candles through (inverse) Compton scattering, which is known as an important component of opacity. This Compton dimming may play an important role in future supernova surveys. From analysis, we find that about a few per cent of the cosmic opacity is caused by Compton dimming in the two models, which can be corrected.

  2. T2 mapping of CT remodelling patterns in interstitial lung disease

    Energy Technology Data Exchange (ETDEWEB)

    Buzan, Maria T.A. [Iuliu Hatieganu University of Medicine and Pharmacy, Department of Pneumology, Cluj-Napoca (Romania); Thoraxklinik at Heidelberg University Hospital, Department of Diagnostic and Interventional Radiology with Nuclear Medicine, Heidelberg (Germany); University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Eichinger, Monika; Heussel, Claus Peter [Thoraxklinik at Heidelberg University Hospital, Department of Diagnostic and Interventional Radiology with Nuclear Medicine, Heidelberg (Germany); Translational Lung Research Center Heidelberg (TLRC), Member of the German Center for Lung Research (DZL), Heidelberg (Germany); Kreuter, Michael; Herth, Felix J. [Translational Lung Research Center Heidelberg (TLRC), Member of the German Center for Lung Research (DZL), Heidelberg (Germany); Thoraxklinik at Heidelberg University Hospital, Department of Pneumology, Center for Rare and Interstitial Lung Diseases, Heidelberg (Germany); Kauczor, Hans-Ulrich [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Translational Lung Research Center Heidelberg (TLRC), Member of the German Center for Lung Research (DZL), Heidelberg (Germany); Warth, Arne [Translational Lung Research Center Heidelberg (TLRC), Member of the German Center for Lung Research (DZL), Heidelberg (Germany); University Hospital Heidelberg, Institute for Pathology, Heidelberg (Germany); Pop, Carmen Monica [Iuliu Hatieganu University of Medicine and Pharmacy, Department of Pneumology, Cluj-Napoca (Romania); Dinkel, Julien [Thoraxklinik at Heidelberg University Hospital, Department of Diagnostic and Interventional Radiology with Nuclear Medicine, Heidelberg (Germany); Translational Lung Research Center Heidelberg (TLRC), Member of the German Center for Lung Research (DZL), Heidelberg (Germany); Comprehensive Pneumology Center Munich (CPC-M), German Center for Lung Research (DZL), Munich (Germany); Ludwig-Maximilians-University Hospital Munich, Institute for Clinical Radiology, Munich (Germany)

    2015-11-15

    To evaluate lung T2 mapping for quantitative characterization and differentiation of ground-glass opacity (GGO), reticulation (RE) and honeycombing (HC) in usual interstitial pneumonia (UIP) and non-specific interstitial pneumonia (NSIP). Twelve patients with stable UIP or NSIP underwent thin-section multislice CT and 1.5-T MRI of the lung. A total of 188 regions were classified at CT into normal (n = 29) and pathological areas, including GGO (n = 48), RE (n = 60) and HC (n = 51) predominant lesions. Entire lung T2 maps based on multi-echo single shot TSE sequence (TE: 20, 40, 79, 140, 179 ms) were generated from each subject with breath-holds at end-expiration and ECG-triggering. The median T2 relaxation of GGO was 67 ms (range 60-72 ms). RE predominant lesions had a median relaxation of 74 ms (range 69-79 ms), while for HC pattern this was 79 ms (range 74-89 ms). The median T2 relaxation for normal lung areas was 41 ms (ranged 38-49 ms), and showed significant difference to pathological areas (p < 0.001). A statistical difference was found between the T2 relaxation of GGO, RE and HC (p < 0.05). The proposed method provides quantitative information for pattern differentiation, potentially allowing for monitoring of progression and response to treatment, in interstitial lung disease. (orig.)

  3. T2 mapping of CT remodelling patterns in interstitial lung disease

    International Nuclear Information System (INIS)

    Buzan, Maria T.A.; Eichinger, Monika; Heussel, Claus Peter; Kreuter, Michael; Herth, Felix J.; Kauczor, Hans-Ulrich; Warth, Arne; Pop, Carmen Monica; Dinkel, Julien

    2015-01-01

    To evaluate lung T2 mapping for quantitative characterization and differentiation of ground-glass opacity (GGO), reticulation (RE) and honeycombing (HC) in usual interstitial pneumonia (UIP) and non-specific interstitial pneumonia (NSIP). Twelve patients with stable UIP or NSIP underwent thin-section multislice CT and 1.5-T MRI of the lung. A total of 188 regions were classified at CT into normal (n = 29) and pathological areas, including GGO (n = 48), RE (n = 60) and HC (n = 51) predominant lesions. Entire lung T2 maps based on multi-echo single shot TSE sequence (TE: 20, 40, 79, 140, 179 ms) were generated from each subject with breath-holds at end-expiration and ECG-triggering. The median T2 relaxation of GGO was 67 ms (range 60-72 ms). RE predominant lesions had a median relaxation of 74 ms (range 69-79 ms), while for HC pattern this was 79 ms (range 74-89 ms). The median T2 relaxation for normal lung areas was 41 ms (ranged 38-49 ms), and showed significant difference to pathological areas (p < 0.001). A statistical difference was found between the T2 relaxation of GGO, RE and HC (p < 0.05). The proposed method provides quantitative information for pattern differentiation, potentially allowing for monitoring of progression and response to treatment, in interstitial lung disease. (orig.)

  4. Upfront triple combination therapy-induced pulmonary edema in a case of pulmonary arterial hypertension associated with Sjogren's syndrome

    Directory of Open Access Journals (Sweden)

    Kimikazu Takeuchi

    Full Text Available Clinical efficacy of combination therapy using vasodilators for pulmonary arterial hypertension (PAH is well established. However, information on its safety are limited. We experienced a case of primary Sjogren's syndrome associated with PAH where the patient developed pulmonary edema immediately after the introduction of upfront triple combination therapy. Although the combination therapy successfully stabilized her pre-shock state, multiple ground glass opacities (GGO emerged. We aborted the dose escalation of epoprostenol and initiated continuous furosemide infusion and noninvasive positive pressure ventilation (NPPV, but this did not prevent an exacerbation of pulmonary edema. Chest computed tomography showing diffuse alveolar infiltrates without inter-lobular septal thickening suggests the pulmonary edema was unlikely due to cardiogenic pulmonary edema and pulmonary venous occlusive disease. Acute respiratory distress syndrome was also denied from no remarkable inflammatory sign and negative results of drug-induced lymphocyte stimulation tests (DLST. We diagnosed the etiological mechanism as pulmonary vasodilator-induced trans-capillary fluid leakage. Following steroid pulse therapy dramatically improved GGO. We realized that overmuch dose escalation of epoprostenol on the top of dual upfront combination poses the risk of pulmonary edema. Steroid pulse therapy might be effective in cases of vasodilator-induced pulmonary edema in Sjogren's syndrome associated with PAH. Keywords: Steroid therapy, Ground glass opacity, Inter-lobular septal thickening, Epoprostenol, Acute respiratory distress syndrome, Trans-capillary fluid leakage

  5. Correlation between pretreatment or follow-up CT findings and therapeutic effect of autologous peripheral blood stem cell transplantation for interstitial pneumonia associated with systemic sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Yabuuchi, Hidetake, E-mail: yabuuchi@shs.kyushu-u.ac.jp [Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan); Matsuo, Yoshio [Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan); Tsukamoto, Hiroshi [Department of Medicine and Biosystemic Science, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan); Sunami, Shunya; Kamitani, Takeshi [Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan); Sakai, Shuji [Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan); Hatakenaka, Masamitsu [Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan); Nagafuji, Koji; Horiuchi, Takahiko; Harada, Mine; Akashi, Koichi [Department of Medicine and Biosystemic Science, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan); Honda, Hiroshi [Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan)

    2011-08-15

    Purpose: To evaluate what is useful among various parameters including CT findings, laboratory parameters (%VC, %DLco, KL-6), patients related data (age, sex, duration of disease) to discriminate between responder and non-responder in patients who received autologous peripheral blood stem cell transplantation (auto-PBSCT) for interstitial pneumonia (IP) with systemic sclerosis (SSc). Method: Auto-PBSCT and follow-up of at least one year by chest CT, serum KL-6, %VC, and %DLco were performed in 15 patients for IP with SSc. Analyzed CT findings included extent of ground-glass opacity (GGO), intralobular reticular opacity, number of segments that showed traction bronchiectasis, and presence of honeycombing. We regarded the therapeutic response of patients as responders when TLC or VC increase over 10% or DLco increase more than 15%, otherwise we have classified as non-responder. We applied univariate and multivariate analyses to find the significant indicators to discriminate responders from non-responders. P < 0.05 was considered statistically significant. Results: Univariate and multivariate analyses showed that the significant parameter to discriminate responders from non-responders were pretreatment KL-6, presence of honeycombing, extent of GGO, and early change in extent of GGO. Among them, extent of GGO and early change in extent of GGO were the strongest discriminators between responders and non-responders (P = 0.001, 0.001, respectively). Conclusion: Several CT findings and pretreatment KL-6 may be useful to discriminate between responder and non-responder in patients who received auto-PBSCT for IP with SSc.

  6. Model-independent Constraints on Cosmic Curvature and Opacity

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Guo-Jian; Li, Zheng-Xiang; Xia, Jun-Qing; Zhu, Zong-Hong [Department of Astronomy, Beijing Normal University, Beijing 100875 (China); Wei, Jun-Jie, E-mail: gjwang@mail.bnu.edu.cn, E-mail: zxli918@bnu.edu.cn, E-mail: xiajq@bnu.edu.cn, E-mail: zhuzh@bnu.edu.cn, E-mail: jjwei@pmo.ac.cn [Purple Mountain Observatory, Chinese Academy of Sciences, Nanjing 210008 (China)

    2017-09-20

    In this paper, we propose to estimate the spatial curvature of the universe and the cosmic opacity in a model-independent way with expansion rate measurements, H ( z ), and type Ia supernova (SNe Ia). On the one hand, using a nonparametric smoothing method Gaussian process, we reconstruct a function H ( z ) from opacity-free expansion rate measurements. Then, we integrate the H ( z ) to obtain distance modulus μ {sub H}, which is dependent on the cosmic curvature. On the other hand, distances of SNe Ia can be determined by their photometric observations and thus are opacity-dependent. In our analysis, by confronting distance moduli μ {sub H} with those obtained from SNe Ia, we achieve estimations for both the spatial curvature and the cosmic opacity without any assumptions for the cosmological model. Here, it should be noted that light curve fitting parameters, accounting for the distance estimation of SNe Ia, are determined in a global fit together with the cosmic opacity and spatial curvature to get rid of the dependence of these parameters on cosmology. In addition, we also investigate whether the inclusion of different priors for the present expansion rate ( H {sub 0}: global estimation, 67.74 ± 0.46 km s{sup −1} Mpc{sup −1}, and local measurement, 73.24 ± 1.74 km s{sup −1} Mpc{sup −1}) exert influence on the reconstructed H ( z ) and the following estimations of the spatial curvature and cosmic opacity. Results show that, in general, a spatially flat and transparent universe is preferred by the observations. Moreover, it is suggested that priors for H {sub 0} matter a lot. Finally, we find that there is a strong degeneracy between the curvature and the opacity.

  7. Experiment to measure oxygen opacity at high density and temperature

    Science.gov (United States)

    Keiter, Paul; Butler, Hannah; Trantham, Matt; Mussack, Katie; Colgan, James; Fontes, Chris; Guzik, Joyce; Kilcrease, David; Perry, Ted; Orban, Chris; Ducret, Jean-Eric; La Pennec, Maelle; Turck-Chieze, Sylvaine; Mancini, Roberto; Heeter, Robert

    2017-10-01

    In recent years, there has been a debate over the abundances of heavy elements (Z >2) in the solar interior. Recent solar atmosphere models [Asplund 2009] find a significantly lower abundance for C, N, and O compared to models used roughly a decade ago. Recent opacity measurements of iron disagree with opacity model predictions [Bailey et al., 2015]. Repeated scrutiny of the experiment and data has not produced a conclusive reason for the discrepancy. New models have been implemented in the ATOMIC opacity code for low-Z elements [Colgan, 2013, Armstrong 2014], however no data currently exists to test the low-Z material models in the regime relevant to the solar convection zone. We present an experimental design using the opacity platform developed at the National Ignition Facility to study the oxygen opacity at densities and temperatures near the solar convection zone conditions. This work is funded by the U.S. DOE, through the NNSA-DS and SC-OFES Joint Program in HEDLP, Grant Number DE-NA0002956, and the NLUF Program, Grant Number DE-NA0002719, and through the LLE, University of Rochester by the NNSA/OICF under No. DE-NA0001944.

  8. Swine-origin influenza A viral (H1N1) infection in children. Chest computed tomography findings

    International Nuclear Information System (INIS)

    Im, Soo-Ah; Kim, Hyo-Lim; Yoon, Jong-seo; Kang, Jin-Han; Lee, Joon-Sung; Chun, Ho-Jong

    2011-01-01

    The aim of this study was to review the chest computed tomography (CT) findings in children with swine-origin influenza (H1N1) virus (S-OIV) infection. The radiologists retrospectively reviewed chest CT findings in 12 children with S-OIV infection and recorded the following findings: ground-glass opacities (GGO), consolidation, nodules, reticular opacities, peribronchial cuffing, and air trapping; distribution; affected lobes. The presence of pleural effusions, pneumomediastinum, pulmonary interstitial emphysema (PIE), and lymphadenopathy was also recorded. Chest CT revealed GGO (67%), consolidation (67%), nodules (25%), peribronchial cuffing (42%), and air trapping (33%). The distribution of the lesions was random (75%), peribronchial (17%), or subpleural (8%). The lobes affected were the lower (92%), upper (58%), and middle (17%) lobes. There were associated pleural effusions (42%), PIE (42%), pneumomediastinum (33%), and lymphadenopathy (75%). Among five patients with air-leak complications, three had a history of allergies and three required the intensive care unit. Chest CT findings in children with S-OIV infection were peribronchial thickening and a mixture of airspace consolidation and GGO with random distribution and lower lobe predominance. Pleural effusion, lymphadenopathy, PIE, and pneumomediastinum may be associated findings. (author)

  9. Verification of Opacity and Diagnosability for Pushdown Systems

    Directory of Open Access Journals (Sweden)

    Koichi Kobayashi

    2013-01-01

    Full Text Available In control theory of discrete event systems (DESs, one of the challenging topics is the extension of theory of finite-state DESs to that of infinite-state DESs. In this paper, we discuss verification of opacity and diagnosability for infinite-state DESs modeled by pushdown automata (called here pushdown systems. First, we discuss opacity of pushdown systems and prove that opacity of pushdown systems is in general undecidable. In addition, a decidable class is clarified. Next, in diagnosability, we prove that under a certain assumption, which is different from the assumption in the existing result, diagnosability of pushdown systems is decidable. Furthermore, a necessary condition and a sufficient condition using finite-state approximations are derived. Finally, as one of the applications, we consider data integration using XML (Extensible Markup Language. The obtained result is useful for developing control theory of infinite-state DESs.

  10. Opacity of expanding media: The effect of spectral lines

    International Nuclear Information System (INIS)

    Karp, A.H.; Lasher, G.; Chan, K.L.; Salpeter, E.E.

    1977-01-01

    Spectral lines are more effective in slowing the transport of radiation in expanding (or contracting) objects than in static ones. The velocity gradient associated with the expansion causes the frequency of the photons to be continuously redshifted relative to the rest frame of the gas through which they travel. Those photons which are redshifted to the frequency of a sufficiently strong line will be absorbed by the corresponding bound-bound transition, and the net effect will be to increase the effective opacity of the gas. In certain cases the effect can be taken into account by using an effective opacity, the expansion opacity, which is a function not only of the temperature and density but also of the velocity gradient.Practical formulae for computing the expansion opacity and its Rosseland mean in terms of sums over spectral lines are derived. It is shown that the cumulative effect of many weak lines can be important, implying that a large list of spectral lines is required to obtain results of even modest accuracy. Numerical computations using the 260,000-entry line list of Kurucz and Peytremann have been completed and some samples of the result are given. The general effect may be important in many astronomical objects, but only in some of these will be detailed approach of this paper be appropriate. In optically thick supernova shells, the effect is important both in maintaining the radiation in thermal equilibrium as it diffuses out of the shell and in increasing the value of the total opacity. The enhancement of the opacity ranges from less than 1% to more than an order of magnitude, depending on the temperature, density, and velocity gradient

  11. Measuring the opacity of stellar interior matter in terrestrial laboratories

    Science.gov (United States)

    Bailey, James

    2015-11-01

    How does energy propagate from the core to the surface of the Sun, where it emerges to warm the Earth? Nearly a century ago Eddington recognized that the attenuation of radiation by stellar matter controls the internal structure of stars like the sun. Opacities for high energy density (HED) matter are challenging to calculate because accurate and complete descriptions of the energy levels, populations, and plasma effects such as continuum lowering and line broadening are needed for partially ionized atoms. This requires approximations, in part because billions of bound-bound and bound-free electronic transitions can contribute to the opacity. Opacity calculations, however, have never been benchmarked against laboratory measurements at stellar interior conditions. Laboratory opacity measurements were limited in the past by the challenges of creating and diagnosing sufficiently large and uniform samples at the extreme conditions found inside stars. In research conducted over more than 10 years, we developed an experimental platform on the Z facility and measured wavelength-resolved iron opacity at electron temperatures Te = 156-195 eV and densities ne = 0.7-4.0 x 1022 cm-3 - conditions very similar to the radiation/convection boundary zone within the Sun. The wavelength-dependent opacity in the 975-1775 eV photon energy range is 30-400% higher than models predict. This raises questions about how well we understand the behavior of atoms in HED plasma. These measurements may also help resolve decade-old discrepancies between solar model predictions and helioseismic observations. This talk will provide an overview of the measurements, investigations of possible errors, and ongoing experiments aimed at testing hypotheses to resolve the model-data discrepancy. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy under contract DE-AC04-94AL85000.

  12. Ultra-dense hot low Z line transition opacity simulations

    International Nuclear Information System (INIS)

    Sauvan, P.; Minguez, E.; Gil, J.M.; Rodriguez, R.; Rubiano, J.G.; Martel, P.; Angelo, P.; Schott, R.; Philippe, F.; Leboucher-Dalimier, E.; Mancini, R.; Calisti, A.

    2002-01-01

    In this work two atomic physics models (the IDEFIX code using the dicenter model and the code based on parametric potentials ANALOP) have been used to calculate the opacities for bound-bound transitions in hot ultra-dense, low Z plasmas. These simulations are in connection with experiments carried out at LULI during the last two years, focused on bound-bound radiation. In this paper H-like opacities for aluminum and fluorine plasmas have been simulated, using both theoretical models, in a wide range of densities and temperatures higher than 200 eV

  13. SOLAR MIXTURE OPACITY CALCULATIONS USING DETAILED CONFIGURATION AND LEVEL ACCOUNTING TREATMENTS

    International Nuclear Information System (INIS)

    Blancard, Christophe; Cossé, Philippe; Faussurier, Gérald

    2012-01-01

    An opacity model (OPAS) combining detailed configuration and level accounting treatments has been developed to calculate radiative opacity of plasmas in local thermodynamic equilibrium. The model is presented and used to compute spectral opacities of a solar mixture. Various density-temperature couples have been considered from the solar center up to the vicinity of the radiative/convective zone interface. For a given solar thermodynamic path, OPAS calculations are compared to Opacity Project (OP) and OPAL data. Rosseland mean opacity values are in very good agreement over all the considered solar thermodynamic path, while OPAS and OP spectral opacities of each element may vary considerably. Main sources of discrepancy are discussed.

  14. FIRST NEW SOLAR MODELS WITH OPAS OPACITY TABLES

    Energy Technology Data Exchange (ETDEWEB)

    Le Pennec, M.; Turck-Chièze, S.; Salmon, S. [CEA/IRFU/Service d’Astrophysique, CE Saclay, F-91191 Gif sur Yvette (France); Blancard, C.; Cossé, P.; Faussurier, G.; Mondet, G. [CEA, DAM, DIF, F-91297 Arpajon (France)

    2015-11-10

    Stellar seismology appears more and more as a powerful tool for a better determination of the fundamental properties of solar-type stars. However, the particular case of the Sun is still challenging. For about a decade now, the helioseismic sound-speed determination has continued to disagree with the standard solar model (SSM) prediction, questioning the reliability of this model. One of the sources of uncertainty could be in the treatment of the transport of radiation from the solar core to the surface. In this Letter, we use the new OPAS opacity tables, recently available for solar modeling, to address this issue. We discuss first the peculiarities of these tables, then we quantify their impact on the solar sound-speed and density profiles using the reduced OPAS tables taken on the grids of the OPAL ones. We use the two evolution codes, Modules for Experiments in Stellar Astrophysics and Code Liégeois d’Evolution Stellaire, that led to similar conclusions in the solar radiative zone. In comparison to commonly used OPAL opacity tables, the new solar models are computed for the most recent photospheric composition with OPAS tables and present improvements to the location of the base of the convective zone and to the description of the solar radiative zone in comparison to the helioseismic observations, even if the differences in the Rosseland mean opacity do not exceed 6%. We finally carry out a comparison to a solar model computed with the OP opacity tables.

  15. Los Alamos Opacities: Transition from LEDCOP to ATOMIC

    International Nuclear Information System (INIS)

    Magee, N.H.; Abdallah, J.; Colgan, J.; Hakel, P.; Kilcrease, D.P.; Mazevet, S.; Sherrill, M.; Fontes, C.J.; Zhang, H.L.

    2004-01-01

    This paper discusses the development of the ATOMIC code, a new low to mid Z opacity code, which will replace the current Los Alamos low Z opacity code LEDCOP. The ATOMIC code is based on the FINE code, long used by the Los Alamos group for spectral comparisons in local thermodynamic equilibrium (LTE) and for non-LTE calculations, utilizing the extensive databases from the atomic physics suite of codes based on the work of R. D. Cowan. Many of the plasma physics packages in LEDCOP, such as line broadening and free-free absorption, are being transferred to the new ATOMIC code. A new equation of state (EOS) model is being developed to allow higher density calculations than were possible with either the FINE or LEDCOP codes. Extensive modernization for both ATOMIC and the atomic physics code suites, including conversion to Fortran 90 and parallelization, are under way to speed up the calculations and to allow the use of expanded databases for both the LTE opacity tables and the non-LTE calculations. Future plans will be outlined, including considerations for new generation opacity tables

  16. Designing the OPAC User Interface to Improve Access and Retrieval.

    Science.gov (United States)

    Basista, Thomas; And Others

    1991-01-01

    Discussion of problems with retrieval of records in library online public access catalogs (OPACs) focuses on an ongoing research project at the Indiana University of Pennsylvania (IUP) that has been trying to improve subject retrieval vocabulary control using natural and thesaural language and on the design of a good graphical user interface.…

  17. Multimedia Visualizer: An Animated, Object-Based OPAC.

    Science.gov (United States)

    Lee, Newton S.

    1991-01-01

    Describes the Multimedia Visualizer, an online public access catalog (OPAC) that uses animated visualizations to make it more user friendly. Pictures of the system are shown that illustrate the interactive objects that patrons can access, including card catalog drawers, librarian desks, and bookshelves; and access to multimedia items is described.…

  18. Library OPACs on the Web: Finding and Describing Directories.

    Science.gov (United States)

    Henry, Marcia

    1997-01-01

    Provides current descriptions of some of the major directories that link to library catalogs on the World Wide Web. Highlights include LibWeb; Hytelnet; WebCats; WWW Library Directory; and techniques for finding new library OPAC (online public access catalog) directories. (LRW)

  19. Web-based OPACs: Between Tradition and Innovation.

    Science.gov (United States)

    Moscoso, Purificacion; Ortiz-Repiso, Virginia

    1999-01-01

    Analyzes the change that Internet-based OPACs (Online Public Access Catalogs) have represented to the structure, administration, and maintenance of the catalogs, retrieval systems, and user interfaces. Examines the structure of databases and traditional principles that have governed systems development. Discusses repercussions of the application…

  20. Terrien's marginal degeneration accompanied by latticed stromal opacities.

    Science.gov (United States)

    Zhang, Yibing; Jia, Hui

    2014-05-01

    We report a case of Terrien's marginal degeneration (TMD) with a unilaterally typical narrow band of peripheral corneal stroma thinning, accompanied by the presence of an unusual network of opacities diffusing throughout the anterior stroma layers. A 43-year-old woman presented with superior nasal peripheral corneal thinning and an unusual network of polygonal stromal opacities in the anterior corneal stroma of the right eye. Latticed corneal changes were unusually extensive and distributed diffusely in the stroma. No abnormalities were found in the corneal epithelium and in the basal epithelial cells. No noticeable changes were found in the left eye. Because of a progressively worse ocular irritation of the right eye, a diagnosis of TMD was made for this patient. This case of TMD accompanied by keratopathy was unusual. The branching stromal lattice pattern of the corneal opacities was difficult to distinguish from lattice corneal dystrophy. In this case, the polygonal stromal opacities were located in the anterior corneal stroma and therefore were distinguished from a similar manifestation in posterior crocodile shagreen.

  1. Terrien’s Marginal Degeneration Accompanied by Latticed Stromal Opacities

    Science.gov (United States)

    Zhang, Yibing; Jia, Hui

    2014-01-01

    ABSTRACT Purpose We report a case of Terrien’s marginal degeneration (TMD) with a unilaterally typical narrow band of peripheral corneal stroma thinning, accompanied by the presence of an unusual network of opacities diffusing throughout the anterior stroma layers. Case Report A 43-year-old woman presented with superior nasal peripheral corneal thinning and an unusual network of polygonal stromal opacities in the anterior corneal stroma of the right eye. Latticed corneal changes were unusually extensive and distributed diffusely in the stroma. No abnormalities were found in the corneal epithelium and in the basal epithelial cells. No noticeable changes were found in the left eye. Because of a progressively worse ocular irritation of the right eye, a diagnosis of TMD was made for this patient. Conclusions This case of TMD accompanied by keratopathy was unusual. The branching stromal lattice pattern of the corneal opacities was difficult to distinguish from lattice corneal dystrophy. In this case, the polygonal stromal opacities were located in the anterior corneal stroma and therefore were distinguished from a similar manifestation in posterior crocodile shagreen. PMID:24681833

  2. An Alternative to EPA Method 9 -- Field Validation of the Digital Opacity Compliance System (DOCS)

    National Research Council Canada - National Science Library

    Rasmussen, Steve L; Stone, Daniel A

    2005-01-01

    The Digital Opacity Compliance System (DOCS) software translates images from a commercial digital camera into visual plume opacity measurements, and is proposed as an alternate reporting method to EPA Method 9...

  3. Assessment of disease activity of idiopathic pulmonary fibrosis (IPF) using FDG PET and high-resolution computed tomography (HRCT)

    International Nuclear Information System (INIS)

    Kim, Bom Sahn; Kang, Won Jun; Oh, So Won; Lee, Jeong Won; Kang, Ji Yeon; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul

    2007-01-01

    Idiopathic pulmonary fibrosis (lPF) is induced by an uncontrolled accumulation and an activation of fibroblasts. The activity of IPF can be assessed according to the degrees of fibrosis and ground glass opacity (GGO) on HRCT. However, it has been thought that FDG PET reflects activity of inflammatory disease. The aim of this study was to compare the HRCT score and FDG uptake in patients with IPF. Six patients with IPF (M: F=4: 2, age 66.513.8 y) who underwent both FDG PET-CT and HRCT were enrolled (interval=33.042.6 d). The activity of IPF was scored at the level of the 1 cm above the diaphragm on HRCT, which was thought to be standard level of lower lobe. The degree of fibrosis was scored from 0 to 5 (0: no fibrosis, 1: interlobular septal wall thickening, 2: 75%). GGO was quantified from 0 to 5 (0: no GGO, 1: = 5 % of the lobe, 2: 5- 75%). Total score of HRCT was defined as the summed score of fibrosis and GGO. Standardized uptake value (SUV) was measured on same plane of FDG PET-CT by manual drawing of region of interest (ROI). SUV ratio of lung to liver was used as a metabolic marker of IPF activity. SUV ratio had a positive correlation with fibrosis score of HRCT (r=0.727, p=0.027), but did not have a significant correlation with GGO score (r=0.228, p=0.556). SUV ratio had a better correlation with total score of HRCT (r=0.895 and p<0.001). We demonstrated that SUV ratio might reflect disease activity of IPF. SUV ratio had a positive correlation with fibrosis score or total score on HRCT. FDG PET could be used to assess disease activity of IPF

  4. Predictors of viral pneumonia in patients with community-acquired pneumonia.

    Directory of Open Access Journals (Sweden)

    Ji Eun Kim

    Full Text Available BACKGROUND: Viruses are increasingly recognized as major causes of community-acquired pneumonia (CAP. Few studies have investigated the clinical predictors of viral pneumonia, and the results have been inconsistent. In this study, the clinical predictors of viral pneumonia were investigated in terms of their utility as indicators for viral pneumonia in patients with CAP. METHODS: Adult patients (≥ 18 years old with CAP, tested by polymerase chain reaction (PCR for respiratory virus, at two teaching hospitals between October 2010 and May 2013, were identified retrospectively. Demographic and clinical data were collected by reviewing the hospital electronic medical records. RESULTS: During the study period, 456 patients with CAP were identified who met the definition, and 327 (72% patients were tested using the respiratory virus PCR detection test. Viral pneumonia (n = 60 was associated with rhinorrhea, a higher lymphocyte fraction in the white blood cells, lower serum creatinine and ground-glass opacity (GGO in radiology results, compared to non-viral pneumonia (n = 250 (p < 0.05, each. In a multivariate analysis, rhinorrhea (Odd ratio (OR 3.52; 95% Confidence interval (CI, 1.58-7.87 and GGO (OR 4.68; 95% CI, 2.48-8.89 were revealed as independent risk factors for viral pneumonia in patients with CAP. The sensitivity, specificity, positive- and negative-predictive values (PPV and NPV of rhinorrhea were 22, 91, 36 and 83%: the sensitivity, specificity, PPV and NPV of GGO were and 43, 84, 40 and 86%, respectively. CONCLUSION: Symptom of rhinorrhea and GGO predicted viral pneumonia in patients with CAP. The high specificity of rhinorrhea and GGO suggested that these could be useful indicators for empirical antiviral therapy.

  5. Assessment of disease activity of idiopathic pulmonary fibrosis (IPF) using FDG PET and high-resolution computed tomography (HRCT)

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bom Sahn; Kang, Won Jun; Oh, So Won; Lee, Jeong Won; Kang, Ji Yeon; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul [Seoul National Univ. College of Medicine, Seoul (Korea, Republic of)

    2007-07-01

    Idiopathic pulmonary fibrosis (lPF) is induced by an uncontrolled accumulation and an activation of fibroblasts. The activity of IPF can be assessed according to the degrees of fibrosis and ground glass opacity (GGO) on HRCT. However, it has been thought that FDG PET reflects activity of inflammatory disease. The aim of this study was to compare the HRCT score and FDG uptake in patients with IPF. Six patients with IPF (M: F=4: 2, age 66.513.8 y) who underwent both FDG PET-CT and HRCT were enrolled (interval=33.042.6 d). The activity of IPF was scored at the level of the 1 cm above the diaphragm on HRCT, which was thought to be standard level of lower lobe. The degree of fibrosis was scored from 0 to 5 (0: no fibrosis, 1: interlobular septal wall thickening, 2: <25 % of the lobe, 3: 25-49 %, 4: 50-75 %, 5: >75%). GGO was quantified from 0 to 5 (0: no GGO, 1: = 5 % of the lobe, 2: 5-<25 %, 3: 25-49 %, 4: 50-75%, 5: >75%). Total score of HRCT was defined as the summed score of fibrosis and GGO. Standardized uptake value (SUV) was measured on same plane of FDG PET-CT by manual drawing of region of interest (ROI). SUV ratio of lung to liver was used as a metabolic marker of IPF activity. SUV ratio had a positive correlation with fibrosis score of HRCT (r=0.727, p=0.027), but did not have a significant correlation with GGO score (r=0.228, p=0.556). SUV ratio had a better correlation with total score of HRCT (r=0.895 and p<0.001). We demonstrated that SUV ratio might reflect disease activity of IPF. SUV ratio had a positive correlation with fibrosis score or total score on HRCT. FDG PET could be used to assess disease activity of IPF.

  6. Models for the computation of opacity of mixtures

    International Nuclear Information System (INIS)

    Klapisch, Marcel; Busquet, Michel

    2013-01-01

    We compare four models for the partial densities of the components of mixtures. These models yield different opacities as shown on polystyrene, acrylic and polyimide in local thermodynamical equilibrium (LTE). Two of these models, the ‘whole volume partial pressure’ model (M1) and its modification (M2) are not thermodynamically consistent (TC). The other two models are TC and minimize free energy. M3, the ‘partial volume equal pressure’ model, uses equality of chemical potential. M4 uses commonality of free electron density. The latter two give essentially identical results in LTE, but M4’s convergence is slower. M4 is easily generalized to non-LTE conditions. Non-LTE effects are shown by the variation of the Planck mean opacity of the mixtures with temperature and density. (paper)

  7. [Glycosaminoglycans in subepithelial opacity after excimer laser keratectomy].

    Science.gov (United States)

    Nakayasu, K; Gotoh, T; Ishikawa, T; Kanai, A

    1996-05-01

    We evaluated histochemically the characteristics of glycosaminoglycans and proteoglycans in the corneal subepithelial opacity after excimer laser keratectomy on rabbit corneas. We also performed the same evaluations on the cornea after mechanical keratectomy. Twenty days after the operations, the area immediately subjacent to the epithelium showed strong staining with toluidine blue, alcian blue, and colloidal iron. However, after treatment with chondroitinase ABC or chondroitinase AC, alcian blue staining in this area decreased dramatically. Antilarge proteoglycan antibody also reacted strongly in this area. Histochemical and immunohistochemical examination of the cornea where mechanical keratectomy was done showed basically similar findings with the cornea of excimer laser keratectomy. These results suggest that large-molecula proteoglycans with chondroitine sulfate side chains become localized in the subepithelial area after two different kinds of keratectomies. We presume from histochemical and immunohistochemical observations that the subepithelial opacity observed after excimer laser keratectomy is not a special reaction to excimer laser but simply a corneal scar formed after stromal resection.

  8. Nuclear opacity for neutrinos at small Q2

    International Nuclear Information System (INIS)

    Kopeliovich, B.Z.

    1989-01-01

    The causes of nuclear screening of the vector and the weak axial currents are quite different. The hadronic fluctuations of neutrino in the nuclear matter live much longer than in the vacuum, due to interaction with nucleons. Nuclear opacity for neutrinos calculated using Glauber-Gribov theory, differs considerably from that given by the Bell optical model. A good agreement of the theory with the recent BEBC WA59 Collaboration measurements is found. 14 refs.; 4 figs

  9. Studies of the experimental technologies of radiative opacity

    International Nuclear Information System (INIS)

    Zhang Jiyan; Yang Guohong; Ding Yaonan; Yang Jiamin; Li Jun; Zhang Wenhai; He Yingling; Wang Yaomei; Huang Haodong

    2004-12-01

    On the SHENGUANG-II laser facility, integrated experiment for opacity measurement was performed and related physical items were studies. In the experiment, some new-typed diagnosing device were also tested. The experiment includes three contents: (1) Investigation of the measurement technique of absorption spectra in the keV region; (2) Investigation of the measurement technique of dual point projection spectroscopy; (3) Investigation of the temperature and density parameters of the experimental samples. (authors)

  10. Lightweight, high-opacity Bible paper by fiber loading

    Science.gov (United States)

    Klaus Doelle; Oliver Heise; John H. Klungness; Said M. AbuBakr

    2000-01-01

    This paper has been prepared in order to discuss Fiber Loading™ for lightweight, high-opacity bible paper. Incorporating fillers within pulp fibers has been subject to research since 1960 (Green et al. 1962, Scallan et al. 1985, Allen et al. 1992). Fiber Loading™ is a method for manufacturing precipitated calcium carbonate (PCC) directly within the pulp processing...

  11. Analysis of irregular opacities of silicosis using computed tomography

    International Nuclear Information System (INIS)

    Maeda, Atsushi; Shida, Hisao; Chiyotani, Keizo; Saito, Kenichi; Mishina, Michihito

    1983-01-01

    Classification in used to codify Chest CT images of abnormalities of the lung in a simple reproducible manner. Simbols to record CT features of importance are listed. We applied CT to 92 cases of silicosis and roentgenological analysis was performed. Bullae, honeycombing, cavity, emphysema, pleural thickning and calcification were more clearly demonstrated in CT images than routine chest roentgenograms. Irregular opacities were considered to be a combined profusion of small round and streak or strand. (author)

  12. IRAS associations with dark clouds of opacity class 6

    International Nuclear Information System (INIS)

    Parker, N.D.

    1988-01-01

    Accurate positions of the opacity class 6 clouds from the Lynds Catalog of Dark Nebulae have been measured on blue and red prints from the Polomar Observatory Sky Survey (POSS) plates. These revised positions and the dimensions of ellipses fitted to the clouds are listed. The IRAS point source catalog has been searched for sources lying within the boundaries of the 147 clouds in the sample. The distribution and properties of these IRAS sources are discussed briefly. (author)

  13. Controlled opacity in a class of nonlinear dielectric media

    Science.gov (United States)

    Bittencourt, E.; Camargo, G. H. S.; De Lorenci, V. A.; Klippert, R.

    2017-03-01

    Motivated by new technologies for designing and tailoring metamaterials, we seek properties for certain classes of nonlinear optical materials that allow room for a reversibly controlled opacity-to-transparency phase transition through the application of external electromagnetic fields. We examine some mathematically simple models for the dielectric parameters of the medium and compute the relevant geometric quantities that describe the speed and polarization of light rays.

  14. Hohlraum modeling for opacity experiments on the National Ignition Facility

    Science.gov (United States)

    Dodd, E. S.; DeVolder, B. G.; Martin, M. E.; Krasheninnikova, N. S.; Tregillis, I. L.; Perry, T. S.; Heeter, R. F.; Opachich, Y. P.; Moore, A. S.; Kline, J. L.; Johns, H. M.; Liedahl, D. A.; Cardenas, T.; Olson, R. E.; Wilde, B. H.; Urbatsch, T. J.

    2018-06-01

    This paper discusses the modeling of experiments that measure iron opacity in local thermodynamic equilibrium (LTE) using laser-driven hohlraums at the National Ignition Facility (NIF). A previous set of experiments fielded at Sandia's Z facility [Bailey et al., Nature 517, 56 (2015)] have shown up to factors of two discrepancies between the theory and experiment, casting doubt on the validity of the opacity models. The purpose of the new experiments is to make corroborating measurements at the same densities and temperatures, with the initial measurements made at a temperature of 160 eV and an electron density of 0.7 × 1022 cm-3. The X-ray hot spots of a laser-driven hohlraum are not in LTE, and the iron must be shielded from a direct line-of-sight to obtain the data [Perry et al., Phys. Rev. B 54, 5617 (1996)]. This shielding is provided either with the internal structure (e.g., baffles) or external wall shapes that divide the hohlraum into a laser-heated portion and an LTE portion. In contrast, most inertial confinement fusion hohlraums are simple cylinders lacking complex gold walls, and the design codes are not typically applied to targets like those for the opacity experiments. We will discuss the initial basis for the modeling using LASNEX, and the subsequent modeling of five different hohlraum geometries that have been fielded on the NIF to date. This includes a comparison of calculated and measured radiation temperatures.

  15. Correlation of tomographic findings with pulmonary function parameters in nonsmoking patients with idiopathic pulmonary fibrosis

    International Nuclear Information System (INIS)

    Lopes, Agnaldo Jose; Capone, Domenico; Mogami, Roberto; Jansen, Jose Manoel .E mail: phel.lop@uol.com.br; Cunha, Daniel Leme da; Melo, Pedro Lopes de

    2007-01-01

    Objective: To correlate tomographic findings with pulmonary function parameters in patients with idiopathic pulmonary fibrosis (IPF). Methods: A cross-sectional study was carried out, in which 30 nonsmoking patients with IPF were evaluated. Using a semiquantitative scoring system, the following high-resolution computerized tomography findings were quantified: total interstitial disease (TID), reticular abnormality/honeycombing, and ground-glass opacity (GGO). The functional variables were measured by spirometry, forced oscillation technique (FOT), helium dilution method, as well as the single-breath method of measuring diffusion capacity of the lung for carbon monoxide (DLCO). Results: Of the 30 patients studied, 18 were female, and 12 were male, with a mean age of 70.9 years. We found that TID and reticular abnormality and honeycombing correlated significantly (negative correlations) with the measurements of forced vital capacity (FVC), total lung capacity (TLC), DLCO, and dynamic respiratory compliance were found, as well as that GGO correlated significantly (and positively) with residual volume/TLC. The ratio of forced expiratory flow between 25 and 75% of FVC to FVC (FEF25-75%/FVC) correlated positively with TID, reticular abnormality/honeycombing, and GGO. Conclusion: In IPF patients, the measurements of volume, diffusion, and dynamic compliance are the physiological variables which best reflect the extent of the interstitial disease on HRCT scans. (author)

  16. Clinical and Radiological Discrimination of Solitary Pulmonary Lesions in Colorectal Cancer Patients.

    Science.gov (United States)

    Ohtaki, Yoichi; Shimizu, Kimihiro; Nagashima, Toshiteru; Nakazawa, Seshiru; Obayashi, Kai; Azuma, Yoko; Iijima, Misaki; Kosaka, Takayuki; Yajima, Toshiki; Ogawa, Hiroomi; Tsutsumi, Soichi; Arai, Motohiro; Mogi, Akira; Kuwano, Hiroyuki

    2018-04-01

    The lung is one of the most common organs of metastasis from colorectal cancer (CRC), and we have encountered lung cancer patients with a history of CRC. There have been few studies regarding methods used to discriminate between primary lung cancer (PLC) and pulmonary metastasis from CRC (PM-CRC) based only on preoperative findings. We retrospectively investigated predictive factors discriminating between these lesions in patients with a history of CRC. Between 2006 and 2015, 117 patients with a history of CRC (44 patients with 47 PLC and 73 patients with 102 PM-CRC) underwent subsequent or concurrent resection of pulmonary lesions. We compared the clinical and radiological characteristics of 100 patients with solitary lesions (43 PLC and 57 PM-CRC). Using univariate and multivariate analyses, we examined predictive factors for discrimination of these two lesions. All tumors with findings of ground-glass opacity (GGO) were PLC (n = 19). In a multivariate analysis of 81 radiologically solid tumors, two factors were found to be significant independent predictors of PLC: a history of stage I CRC and presence of pleural indentation. All tumors in 26 patients with either GGO or both a stage I CRC history and pleural indentation were PLC, while most tumors in patients without all three factors were PM-CRC (43/44; 97.7%). The presence or absence of GGO, pathological CRC stage, and pleural indentation could be useful factors to distinguish between PLC and PM-CRC.

  17. Correlation of tomographic findings with pulmonary function parameters in nonsmoking patients with idiopathic pulmonary fibrosis

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Agnaldo Jose; Capone, Domenico; Mogami, Roberto; Jansen, Jose Manoel [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). School of Medical Sciences].E mail: phel.lop@uol.com.br; Cunha, Daniel Leme da [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Pedro Ernesto University Hospital. Dept. of Radiology and Diagnostic Imaging; Melo, Pedro Lopes de [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Inst. of Biology

    2007-11-15

    Objective: To correlate tomographic findings with pulmonary function parameters in patients with idiopathic pulmonary fibrosis (IPF). Methods: A cross-sectional study was carried out, in which 30 nonsmoking patients with IPF were evaluated. Using a semiquantitative scoring system, the following high-resolution computerized tomography findings were quantified: total interstitial disease (TID), reticular abnormality/honeycombing, and ground-glass opacity (GGO). The functional variables were measured by spirometry, forced oscillation technique (FOT), helium dilution method, as well as the single-breath method of measuring diffusion capacity of the lung for carbon monoxide (DLCO). Results: Of the 30 patients studied, 18 were female, and 12 were male, with a mean age of 70.9 years. We found that TID and reticular abnormality and honeycombing correlated significantly (negative correlations) with the measurements of forced vital capacity (FVC), total lung capacity (TLC), DLCO, and dynamic respiratory compliance were found, as well as that GGO correlated significantly (and positively) with residual volume/TLC. The ratio of forced expiratory flow between 25 and 75% of FVC to FVC (FEF25-75%/FVC) correlated positively with TID, reticular abnormality/honeycombing, and GGO. Conclusion: In IPF patients, the measurements of volume, diffusion, and dynamic compliance are the physiological variables which best reflect the extent of the interstitial disease on HRCT scans. (author)

  18. Perfusion- and pattern-based quantitative CT indexes using contrast-enhanced dual-energy computed tomography in diffuse interstitial lung disease: relationships with physiologic impairment and prediction of prognosis

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Jung Won [Sungkyunkwan University School of Medicine, Department of Radiology, Kangbuk Samsung Hospital, Seoul (Korea, Republic of); Bae, Jang Pyo; Kim, Namkug; Chang, Yongjun; Seo, Joon Beom [University of Ulsan College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Lee, Ho Yun; Lee, Kyung Soo [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of); Chung, Man Pyo; Park, Hye Yun [Sungkyunkwan University School of Medicine, Department of Pulmonology, Samsung Medical Center, Seoul (Korea, Republic of)

    2016-05-15

    To evaluate automated texture-based segmentation of dual-energy CT (DECT) images in diffuse interstitial lung disease (DILD) patients and prognostic stratification by overlapping morphologic and perfusion information of total lung. Suspected DILD patients scheduled for surgical biopsy were prospectively included. Texture patterns included ground-glass opacity (GGO), reticulation and consolidation. Pattern- and perfusion-based CT measurements were assessed to extract quantitative parameters. Accuracy of texture-based segmentation was analysed. Correlations between CT measurements and pulmonary function test or 6-minute walk test (6MWT) were calculated. Parameters of idiopathic pulmonary fibrosis/usual interstitial pneumonia (IPF/UIP) and non-IPF/UIP were compared. Survival analysis was performed. Overall accuracy was 90.47 % for whole lung segmentation. Correlations between mean iodine values of total lung, 50-97.5th (%) attenuation and forced vital capacity or 6MWT were significant. Volume of GGO, reticulation and consolidation had significant correlation with DLco or SpO{sub 2} on 6MWT. Significant differences were noted between IPF/UIP and non-IPF/UIP in 6MWT distance, mean iodine value of total lung, 25-75th (%) attenuation and entropy. IPF/UIP diagnosis, GGO ratio, DILD extent, 25-75th (%) attenuation and SpO{sub 2} on 6MWT showed significant correlations with survival. DECT combined with pattern analysis is useful for analysing DILD and predicting survival by provision of morphology and enhancement. (orig.)

  19. Asymmetry in acute exacerbation of idiopathic pulmonary fibrosis

    Directory of Open Access Journals (Sweden)

    Akihiko Sokai

    2017-04-01

    Full Text Available Acute exacerbation (AE of idiopathic pulmonary fibrosis (IPF results in poor survival. The objective of the present study was to elucidate the impact of asymmetrical ground-glass opacity (GGO and/or consolidation on outcomes in patients with AE-IPF. The cases of 59 consecutive patients with AE-IPF were retrospectively reviewed. High-resolution computed tomography (HRCT at diagnosis of an AE was assessed to determine the disease extent and asymmetry. Asymmetrical AE was defined as a right-to-left ratio of GGO and consolidation ≥2.0 or ≤0.5. The impacts of HRCT indices and other clinical parameters on 180-day mortality were analysed. The overall 180-day mortality rate was 59.2%, and asymmetrical AE was observed in 13 patients (22.0%. A multivariate analysis revealed that asymmetrical AE was a significant predictor of 180-day mortality (hazard ratio=0.36, p=0.047, long-term oxygen therapy before AE and serum lactate dehydrogenase levels. The 180-day mortality of patients with asymmetrical AE was significantly lower than that of patients with symmetrical AE (asymmetrical AE 30.8% versus symmetrical AE 68.2%, p=0.03. An asymmetrical distribution of GGO and/or consolidation is a predictor of survival in patients with AE-IPF.

  20. CT findings of pulmonary hypertension

    International Nuclear Information System (INIS)

    Inoue, Yukio; Tanimoto, Akihiro; Sato, Toru; Kuribayashi, Sachio

    2006-01-01

    For the treatment for pulmonary hypertension (PH), the differential diagnosis of its causal diseases is essential. To determine whether X-ray CT is useful for differentiating PH, we reviewed CT findings of 53 patients (18 men and 35 women, mean age of 44.9) given a diagnosis of PH, consisting of 25 with primary pulmonary hypertension (PPH), 18 with chronic pulmonary embolism (cPE), 6 with Eisenmenger syndrome, 5 cases of collagen diseases, 2 of acute PE, and 1 of cor pulmonale. The intrapulmonary distribution of CT findings (ground glass opacity [GGO], mosaic attenuation, striation and/or infiltration, and interlobular septal thickening) were reviewed and scored on a 4-point scale (grade 0: no findings, 1: involving one third of the lung, 2: involving one-two thirds, and 3: diffuse distribution) by two radiologists who reached a consensus. PPH showed preferentially diffuse distribution of GGO as compared with cPE (p<0.05). However, there was no apparent relationship between the pulmonary vascular resistance and the distribution of GGO in PPH cases. The mosaic attenuation pattern was more frequent in cPE (43%) than PPH (12%; p<0.05). Striation and/or infiltration was observed in 36% of cPE, but only 4% of PPH. Interlobular septal thickening was seen in 16% of PPH, and 0% in cPE. Evaluation of CT findings is useful to differentiate PH. (author)

  1. The Opacity of Russian-Ukrainian Energy Relations

    International Nuclear Information System (INIS)

    Dubien, A.

    2007-01-01

    Energy issues lie at the heart of Ukraine's economic, political and strategic challenges. A year after the 'orange revolution', the 'gas war' served to highlight the country's vulnerable position, being 80% dependent on imports of gas and having the world's most energy hungry economy. The 2005 crisis also highlighted the extreme opacity of the country's bilateral relations with Russia, which are governed as much by the interests surrounding Gazprom's relations as by those of the state. Yanukovich's return to power in the summer of 2006 coincided with a relative appeasement of relations with Moscow and a new division of spheres of influence in the Ukrainian energy sector. (author)

  2. Model of opacity and emissivity of non-equilibrium plasma

    International Nuclear Information System (INIS)

    Politov V Y

    2008-01-01

    In this work the model describing absorption and emission properties of the non-equilibrium plasma is presented. It is based on the kinetics equations for populations of the ground, singly and doubly excited states of multi-charged ions. After solving these equations, the states populations together with the spectroscopic data, supplied in the special database for a lot ionization stages, are used for building the spectral distributions of plasma opacity and emissivity in STA approximation. Results of kinetics simulation are performed for such important X-ray converter as gold, which is investigated intensively in ICF-experiments

  3. A fully blanketed early B star LTE model atmosphere using an opacity sampling technique

    International Nuclear Information System (INIS)

    Phillips, A.P.; Wright, S.L.

    1980-01-01

    A fully blanketed LTE model of a stellar atmosphere with Tsub(e) = 21914 K (thetasub(e) = 0.23), log g = 4 is presented. The model includes an explicit representation of the opacity due to the strongest lines, and uses a statistical opacity sampling technique to represent the weaker line opacity. The sampling technique is subjected to several tests and the model is compared with an atmosphere calculated using the line-distribution function method. The limitations of the distribution function method and the particular opacity sampling method used here are discussed in the light of the results obtained. (author)

  4. Systematic measurements of opacity dependence on temperature, density, and atomic number at stellar interior conditions

    Science.gov (United States)

    Nagayama, Taisuke

    2017-10-01

    Model predictions for iron opacity are notably different from measurements performed at matter conditions similar to the boundary between the solar radiation and convection zones. The calculated iron opacities have narrower spectral lines, weaker quasi-continuum at short wavelength, and deeper opacity windows than the measurements. If correct, these measurements help resolve a decade old problem in solar physics. A key question is therefore: What is responsible for the model-data discrepancy? The answer is complex because the experiments are challenging and opacity theories depend on multiple entangled physical processes such as the influence of completeness and accuracy of atomic states, line broadening, contributions from myriad transitions from excited states, and multi-photon absorption processes. To help determine the cause of this discrepancy, a systematic study of opacity variation with temperature, density, and atomic number is underway. Measurements of chromium, iron, and nickel opacities have been performed at two different temperatures and densities. The collection of measured opacities provides constraints on hypotheses to explain the discrepancy. We will discuss implications of measured opacities, experimental errors, and possible opacity model refinements. Sandia National Laboratories is a multi-mission laboratory managed and operated by National Technology and Engineering Solutions of Sandia, LLC., a wholly owned subsidiary of Honeywell International, Inc., for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-NA0003525.

  5. Use of Fourier-Domain Optical Coherence Tomography to Evaluate Anterior Stromal Opacities in Donor Corneas

    Directory of Open Access Journals (Sweden)

    Matthew R. Bald

    2013-01-01

    Full Text Available Purpose. To evaluate Fourier-domain optical coherence tomography (FD-OCT as an adjunct to traditional slit lamp examination of donor corneas with suspected Anterior Stromal Opacities. Methods. Seven corneas suspected of having anterior stromal opacities by slit lamp examination were evaluated with FD-OCT. Each cornea was evaluated to confirm the presence of opacity and, if present, the depth of opacity was measured. Results. The opacity depth ranged from 82 μm to 624 μm. The initial slit lamp impressions of five of the seven corneas were confirmed by OCT. In two corneas, the OCT findings were different from the initial slit lamp impressions. Slit lamp examination of the first cornea gave the impression of anterior stromal scarring, but OCT showed that the opacity was limited to the epithelium. Slit lamp examination of the second cornea suggested opacity limited to the epithelium, but OCT identified significant sub-Bowman's scarring. In all cases, the Eye Bank Technicians reported that the location and depth of corneal opacity were more sharply defined by OCT than by slit lamp. Conclusion. The high resolution of OCT makes it easier to determine the location of corneal opacities compared to slit lamp examinations. This enhanced visualization can improve decisions regarding transplant suitability of donor corneas.

  6. Experimental study of self-backlighting method for opacity

    International Nuclear Information System (INIS)

    Ding Yaonan; Yang Jiamin; Li Sanwei; Cao Leifeng; Wang Yaomei; Zhang Wenhai; Chen Bo; Yu Yanning; Wang Hongbin

    2001-01-01

    Self-backlighting method for opacity measurement has been suggested and studied, based on the actual condition of Xingguang II laser facility. An 80 J and 350 nm laser, which has a duration of about 700 ps, irradiates on a newly designed target and creates intense X-ray radiation acting as both heating source and backlighter source. The heated sample has been spatially imaged to obtain X-ray spectra from X-ray source region, transmission region and self-emission region of the sample at the same shot by spatially resolved transmission grating spectrometer in which dispersed X-ray is recorded by X-ray CCD. The samples are low-Z CH foam with density of 0.042 g/cm 3 , thickness of 42 μm and mid-Z Al with density of 2.7 g/cm 3 , thickness of 0.5 μm or 1.0 μm. Mass absorption coefficients of the heated sample as function of the photon energy have been obtained experimentally in the same shot. The spectra line emitted from the heated CH foam has also been measured by OHM crystal spectrometer, which has been used to determine the temperature of the sample. The experimental results for opacity of carbon have been discussed

  7. TIPTOPbase: the Iron Project and the Opacity Project Atomic Database

    Science.gov (United States)

    Mendoza, Claudio; Nahar, Sultana; Pradhan, Anil; Seaton, Micheal; Zeippen, Claude

    2001-05-01

    The Opacity Project, the IRON Project, and the RmaX Network (The Opacity Project Team, Vol.1,2), IOPP, Bristol (1995,1996); Hummer et al., Astron. Astrophys. 279, 298 (1993) are international computational efforts concerned with the production of high quality atomic data for astrophysical applications. Research groups from Canada, France, Germany, UK, USA and Venezuela are involved. Extensive data sets containing accurate energy levels, f-values, A-values, photoionisation cross sections, collision strengths, recombination rates, and opacitites have been computed for cosmically abundant elements using state-of-the-art atomic physics codes. Their volume, completeness and overall accuracy are presently unmatched in the field of laboratory astrophysics. Some of the data sets have been available since 1993 from a public on-line database service referred to as TOPbase (Cunto et al Astron. Astrophys. 275), L5 (1993), ( http://cdsweb.u-strasbg.fr/OP.html at CDS France, and http://heasarc.gsfc.nasa.gov/topbase, at NSAS USA). We are currently involved in a major effort to scale the existing database services to develop a robust platform for the high-profile dissemination of atomic data to the scientific community within the next 12 months. (Partial support from the NSF and NASA is acknowledged.)

  8. Statistical approach for calculating opacities of high-Z plasmas

    International Nuclear Information System (INIS)

    Nishikawa, Takeshi; Nakamura, Shinji; Takabe, Hideaki; Mima, Kunioki

    1992-01-01

    For simulating the X-ray radiation from laser produced high-Z plasma, an appropriate atomic modeling is necessary. Based on the average ion model, we have used a rather simple atomic model for opacity calculation in a hydrodynamic code and obtained a fairly good agreement with the experiment on the X-ray spectra from the laser-produced plasmas. We have investigated the accuracy of the atomic model used in the hydrodynamic code. It is found that transition energies of 4p-4d, 4d-4f, 4p-5d, 4d-5f and 4f-5g, which are important in laser produced high-Z plasma, can be given within an error of 15 % compared to the values by the Hartree-Fock-Slater (HFS) calculation and their oscillator strengths obtained by HFS calculation vary by a factor two according to the difference of charge state. We also propose a statistical method to carry out detail configuration accounting for electronic state by use of the population of bound electrons calculated with the average ion model. The statistical method is relatively simple and provides much improvement in calculating spectral opacities of line radiation, when we use the average ion model to determine electronic state. (author)

  9. Light element opacities of astrophysical interest from ATOMIC

    Energy Technology Data Exchange (ETDEWEB)

    Colgan, J.; Kilcrease, D. P.; Magee, N. H. Jr.; Armstrong, G. S. J.; Abdallah, J. Jr.; Sherrill, M. E. [Theoretical Division, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Fontes, C. J.; Zhang, H. L.; Hakel, P. [Computational Physics Division, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States)

    2013-07-11

    We present new calculations of local-thermodynamic-equilibrium (LTE) light element opacities from the Los Alamos ATOMIC code for systems of astrophysical interest. ATOMIC is a multi-purpose code that can generate LTE or non-LTE quantities of interest at various levels of approximation. Our calculations, which include fine-structure detail, represent a systematic improvement over previous Los Alamos opacity calculations using the LEDCOP legacy code. The ATOMIC code uses ab-initio atomic structure data computed from the CATS code, which is based on Cowan's atomic structure codes, and photoionization cross section data computed from the Los Alamos ionization code GIPPER. ATOMIC also incorporates a new equation-of-state (EOS) model based on the chemical picture. ATOMIC incorporates some physics packages from LEDCOP and also includes additional physical processes, such as improved free-free cross sections and additional scattering mechanisms. Our new calculations are made for elements of astrophysical interest and for a wide range of temperatures and densities.

  10. High-resolution computed tomography findings of influenza virus pneumonia. A comparative study between seasonal and novel (H1N1) influenza virus pneumonia

    International Nuclear Information System (INIS)

    Tanaka, Nobuyuki; Kunihiro, Yoshie; Matsunaga, Naofumi; Hasegawa, Shunji; Ichiyama, Takashi; Emoto, Takuya; Suda, Hiroki

    2012-01-01

    The purpose of this study was to evaluate the high-resolution computed tomography (HRCT) findings of novel influenza virus (n-IFV) pneumonia and compare them with the findings for seasonal (s-IFV) pneumonia. We evaluated 29 cases of pure IFV pneumonia that occurred between 1990 and 2010. We evaluated the existence, extent, and patterns of HRCT findings and compared these features between s-IFV and n-IFV. Consolidation was less frequent in s-IFV than in n-IFV (40.0 vs. 84.2%, respectively; p=0.014). Consolidation with a loss of volume was frequent in n-IFV (62.5%). There was no significant difference in the occurrence of ground-glass opacity (GGO) between s-IFV and n-IFV (100 vs. 84.2%, respectively). GGO with reticular opacities was more frequent in s-IFV than in n-IFV (70.0 vs. 25.0%, respectively; p=0.024). The frequency of nodules was not significantly different between the two groups. The mosaic pattern was more frequent in s-IFV than in n-IFV patients (80.0 vs. 15.8%, respectively; p=0.0007). Mucoid impaction was more frequent in patients with n-IFV than with s-IFV (52.6 vs. 10.0%, respectively; p=0.025). Consolidation and mucoid impaction were more frequent in n-IFV, whereas GGO with reticular opacities and a mosaic pattern occurred more frequently in s-IFV; otherwise, there were no significant differences between the two groups. (author)

  11. Opacity Build-up in Impulsive Relativistic Sources

    International Nuclear Information System (INIS)

    Granot, Jonathan; Cohen-Tanugi, Johann; Silva, Eduardo do Couto e

    2007-01-01

    Opacity effects in relativistic sources of high-energy gamma-rays, such as gamma-ray bursts (GRBs) or Blazars, can probe the Lorentz factor of the outflow as well as the distance of the emission site from the source, and thus help constrain the composition of the outflow (protons, pairs, magnetic field) and the emission mechanism. Most previous works consider the opacity in steady state. Here we study the effects of the time dependence of the opacity to pair production (γγ → e + e - ) in an impulsive relativistic source, which may be relevant for the prompt gamma-ray emission in GRBs or flares in Blazars. We present a simple, yet rich, semi-analytic model for the time and energy dependence of the optical depth, τγγ, in which a thin spherical shell expands ultra-relativistically and emits isotropically in its own rest frame over a finite range of radii, R 0 (le) R (le) R 0 +ΔR. This is particularly relevant for GRB internal shocks. We find that in an impulsive source (ΔR ∼ 0 ), while the instantaneous spectrum (which is typically hard to measure due to poor photon statistics) has an exponential cutoff above the photon energy (var e psilon)1(T) where tγγ((var e psilon)1) = 1, the time integrated spectrum (which is easier to measure) has a power-law high-energy tail above the photon energy (var e psilon)1* ∼ (var e psilon)1(ΔT) where ΔT is the duration of the emission episode. Furthermore, photons with energies (var e psilon) > (var e psilon)1* are expected to arrive mainly near the onset of the spike in the light curve or flare, which corresponds to the short emission episode. This arises since in such impulsive sources it takes time to build-up the (target) photon field, and thus the optical depth τγγ((var e psilon)) initially increases with time and (var e psilon)1(T) correspondingly decreases with time, so that photons of energy (var e psilon) > (var e psilon)1* are able to escape the source mainly very early on while (var e psilon)1(T) > (var

  12. Experimental investigation of opacity models for stellar interior, inertial fusion, and high energy density plasmas

    International Nuclear Information System (INIS)

    Bailey, J. E.; Rochau, G. A.; Mancini, R. C.; Iglesias, C. A.; MacFarlane, J. J.; Golovkin, I. E.; Blancard, C.; Cosse, Ph.; Faussurier, G.

    2009-01-01

    Theoretical opacities are required for calculating energy transport in plasmas. In particular, understanding stellar interiors, inertial fusion, and Z pinches depends on the opacities of mid-atomic-number elements over a wide range of temperatures. The 150-300 eV temperature range is particularly interesting. The opacity models are complex and experimental validation is crucial. For example, solar models presently disagree with helioseismology and one possible explanation is inadequate theoretical opacities. Testing these opacities requires well-characterized plasmas at temperatures high enough to produce the ion charge states that exist in the sun. Typical opacity experiments heat a sample using x rays and measure the spectrally resolved transmission with a backlight. The difficulty grows as the temperature increases because the heating x-ray source must supply more energy and the backlight must be bright enough to overwhelm the plasma self-emission. These problems can be overcome with the new generation of high energy density (HED) facilities. For example, recent experiments at Sandia's Z facility [M. K. Matzen et al., Phys. Plasmas 12, 055503 (2005)] measured the transmission of a mixed Mg and Fe plasma heated to 156±6 eV. This capability will also advance opacity science for other HED plasmas. This tutorial reviews experimental methods for testing opacity models, including experiment design, transmission measurement methods, accuracy evaluation, and plasma diagnostics. The solar interior serves as a focal problem and Z facility experiments illustrate the techniques.

  13. A Comparison of Keyword Subject Searching on Six British University OPACs Online Public Access Catalogs.

    Science.gov (United States)

    Aanonson, John

    1987-01-01

    Compares features of online public access catalogs (OPACs) at six British universities: (1) Cambridge; (2) Hull; (3) Newcastle; (4) Surrey; (5) Sussex; and (6) York. Results of keyword subject searches on two topics performed on each of the OPACs are reported and compared. Six references are listed. (MES)

  14. Bibliographic Displays in OPACs and Web Catalogs: How Well Do They Comply with Display Guidelines?

    Science.gov (United States)

    Cherry, Joan M.

    1998-01-01

    Evaluation of data from assessments of full bibliographic displays in academic library OPACs (online public access catalogs) and World Wide Web catalogs against a checklist of desirable features found that OPAC displays scored 58% and Web displays scored 60%. Discusses weaknesses, focusing on those found in the majority of the displays…

  15. The Searching Behavior of Remote Users: A Study of One Online Public Access Catalog (OPAC).

    Science.gov (United States)

    Kalin, Sally W.

    1991-01-01

    Describes a study that was conducted to determine whether the searching behavior of remote users of LIAS (Library Information Access System), Pennsylvania State University's online public access catalog (OPAC), differed from those using the OPAC within the library. Differences in search strategies and in user satisfaction are discussed. (eight…

  16. Co-registration of pre-operative CT with ex vivo surgically excised ground glass nodules to define spatial extent of invasive adenocarcinoma on in vivo imaging: a proof-of-concept study

    Energy Technology Data Exchange (ETDEWEB)

    Rusu, Mirabela [Case Western Reserve University, Department of Biomedical Engineering, Cleveland, OH (United States); GE Global Research, Niskayuna, NY (United States); Rajiah, Prabhakar [UT Southwestern Medical Center, Dallas, TX (United States); Cleveland Medical Center and Case Western Reserve University, University Hospitals, Cleveland, OH (United States); Gilkeson, Robert; Yang, Michael; Donatelli, Christopher; Linden, Philip [Cleveland Medical Center and Case Western Reserve University, University Hospitals, Cleveland, OH (United States); Thawani, Rajat; Madabhushi, Anant [Case Western Reserve University, Department of Biomedical Engineering, Cleveland, OH (United States); Jacono, Frank J. [Cleveland Medical Center and Case Western Reserve University, University Hospitals, Cleveland, OH (United States); Louis Stokes Cleveland VA Medical Center, Cleveland, OH (United States)

    2017-10-15

    To develop an approach for radiology-pathology fusion of ex vivo histology of surgically excised pulmonary nodules with pre-operative CT, to radiologically map spatial extent of the invasive adenocarcinomatous component of the nodule. Six subjects (age: 75 ± 11 years) with pre-operative CT and surgically excised ground-glass nodules (size: 22.5 ± 5.1 mm) with a significant invasive adenocarcinomatous component (>5 mm) were included. The pathologist outlined disease extent on digitized histology specimens; two radiologists and a pulmonary critical care physician delineated the entire nodule on CT (in-plane resolution: <0.8 mm, inter-slice distance: 1-5 mm). We introduced a novel reconstruction approach to localize histology slices in 3D relative to each other while using CT scan as spatial constraint. This enabled the spatial mapping of the extent of tumour invasion from histology onto CT. Good overlap of the 3D reconstructed histology and the nodule outlined on CT was observed (65.9 ± 5.2%). Reduction in 3D misalignment of corresponding anatomical landmarks on histology and CT was observed (1.97 ± 0.42 mm). Moreover, the CT attenuation (HU) distributions were different when comparing invasive and in situ regions. This proof-of-concept study suggests that our fusion method can enable the spatial mapping of the invasive adenocarcinomatous component from 2D histology slices onto in vivo CT. (orig.)

  17. Co-registration of pre-operative CT with ex vivo surgically excised ground glass nodules to define spatial extent of invasive adenocarcinoma on in vivo imaging: a proof-of-concept study

    International Nuclear Information System (INIS)

    Rusu, Mirabela; Rajiah, Prabhakar; Gilkeson, Robert; Yang, Michael; Donatelli, Christopher; Linden, Philip; Thawani, Rajat; Madabhushi, Anant; Jacono, Frank J.

    2017-01-01

    To develop an approach for radiology-pathology fusion of ex vivo histology of surgically excised pulmonary nodules with pre-operative CT, to radiologically map spatial extent of the invasive adenocarcinomatous component of the nodule. Six subjects (age: 75 ± 11 years) with pre-operative CT and surgically excised ground-glass nodules (size: 22.5 ± 5.1 mm) with a significant invasive adenocarcinomatous component (>5 mm) were included. The pathologist outlined disease extent on digitized histology specimens; two radiologists and a pulmonary critical care physician delineated the entire nodule on CT (in-plane resolution: <0.8 mm, inter-slice distance: 1-5 mm). We introduced a novel reconstruction approach to localize histology slices in 3D relative to each other while using CT scan as spatial constraint. This enabled the spatial mapping of the extent of tumour invasion from histology onto CT. Good overlap of the 3D reconstructed histology and the nodule outlined on CT was observed (65.9 ± 5.2%). Reduction in 3D misalignment of corresponding anatomical landmarks on histology and CT was observed (1.97 ± 0.42 mm). Moreover, the CT attenuation (HU) distributions were different when comparing invasive and in situ regions. This proof-of-concept study suggests that our fusion method can enable the spatial mapping of the invasive adenocarcinomatous component from 2D histology slices onto in vivo CT. (orig.)

  18. Opacity calculations and Saha's equation for high Z elements

    International Nuclear Information System (INIS)

    Godwal, B.K.; Sikka, S.K.

    1977-01-01

    Opacity calculations are needed for energy transport by radiation for high Z element plasmas as these have been suggested as temper materials in laser, electron beam and heavy ion fusion schemes. The pressure ionised modified form of Saha's ionisation equation has been used to obtain the free electron density, populations of various ionic species and the populations of various energy states for a given ion. Results are presented for two typical elements; tungsten and uranium. The ionisation potential have been evaluated using the Bohr's formula with suitable effective screened charges for ions. The results show that for uranium, even at a temperature of 10 kev, the K shell is intact. The reliability of the Saha's equation solution has been checked by comparing the equation of state (total pressure vs total energy curve) with that given by the Thomas-Fermi-Dirac equation of state. The agreement between the two is good from temperature upwards of 0.2 kev. (author)

  19. Neutrino opacities in kaon condensation and evolution of neutron stars

    Energy Technology Data Exchange (ETDEWEB)

    Muto, Takumi [Chiba Institute of Technology, Dept. of Physics, Narashino, Chiba (Japan); Yasuhira, Masatomi [Kyoto Univ., Yukawa Institute for Theoretical Physics, Kyoto (Japan); Tatsumi, Toshitaka [Kyoto Univ., Dept. of Physics, Kyoto (Japan); Iwamoto, Naoki [Kagawa Univ., Faculty of Engineering, Takamatsu, Kagawa (Japan)

    2002-09-01

    The neutrino mean free paths are obtained in kaon condensates realized from hot neutron-star matter. Kaon-induced neutrino absorption processes (KA), {nu}{sub e}N {yields} e{sup -}N (N stands for the nucleon), which are unique in the presence of kaon condensates, are mainly considered in nondegenerate neutrino case. The mean free paths for the KA processes are compared with the neutrino scatterings (S), {nu}{sub e}N {yields} {nu}{sub e}N. It is shown that the mean free paths for KA are shorter than the ordinary two-nucleon processes, {nu}{sub e}nN {yields} e{sup -}pN by several orders of magnitude when the temperature is not very high. However, the scattering processes have a dominant contribution to the neutrino opacities as compared with KA, so that KA has a minor effect on the thermal and dynamical evolution of protoneutron stars. (author)

  20. Opacity measurements in shock-generated argon plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Erskine, D.

    1993-07-01

    Dense plasmas having uniform and constant density and temperature are generated by passage of a planar shock wave through gas. The opacity of the plasma is accurately measured versus wavelength by recording the risetime of emitted light. This technique is applicable to a wide variety of species and plasma conditions. Initial experiments in argon have produced plasmas with 2 eV temperatures, 0.004--0.04 g/cm{sup 3} densities, and coupling parameters {Gamma} {approximately}0.3--0.7. Measurements in visible light are compared with calculations using the HOPE code. An interesting peak in the capacity at 400 nm is observed for the first time and is identified with the 4s-5p transition in excited neutral argon atoms.

  1. Formation of Planetary Populations I: Metallicity & Envelope Opacity Effects

    Science.gov (United States)

    Alessi, Matthew; Pudritz, Ralph E.

    2018-05-01

    We present a comprehensive body of simulations of the formation of exoplanetary populations that incorporate the role of planet traps in slowing planetary migration. The traps we include in our model are the water ice line, the disk heat transition, and the dead zone outer edge. We reduce our model parameter set to two physical parameters: the opacity of the accreting planetary atmospheres (κenv) and a measure of the efficiency of planetary accretion after gap opening (fmax). We perform planet population synthesis calculations based on the initial observed distributions of host star and disk properties - their disk masses, lifetimes, and stellar metallicities. We find the frequency of giant planet formation scales with disk metallicity, in agreement with the observed Jovian planet frequency-metallicity relation. We consider both X-ray and cosmic ray disk ionization models, whose differing ionization rates lead to different dead zone trap locations. In both cases, Jovian planets form in our model out to 2-3 AU, with a distribution at smaller radii dependent on the disk ionization source and the setting of envelope opacity. We find that low values of κenv (0.001-0.002 cm2 g-1) and X-ray disk ionization are necessary to obtain a separation between hot Jupiters near 0.1 AU, and warm Jupiters outside 0.6 AU, a feature present in the data. Our model also produces a large number of super Earths, but the majority are outside of 2 AU. As our model assumes a constant dust to gas ratio, we suggest that radial dust evolution must be taken into account to reproduce the observed super Earth population.

  2. Interstitial lung disease associated with collagen vascular disorders: disease quantification using a computer-aided diagnosis tool

    International Nuclear Information System (INIS)

    Marten, K.; Engelke, C.; Dicken, V.; Kneitz, C.; Hoehmann, M.; Kenn, W.; Hahn, D.

    2009-01-01

    The purpose of this study was to evaluate a computer-aided diagnosis (CAD) tool compared to human observers in quantification of interstitial lung disease (ILD) in patients with collagen-vascular disorders. A total of 52 patients with rheumatoid arthritis (n=24), scleroderma (n=14) and systemic lupus erythematosus (n=14) underwent thin-section CT. Two independent observers assessed the extent of ILD (EoILD), reticulation (EoRet) and ground-glass opacity (EoGGO). CAD assessed EoILD twice. Pulmonary function tests were obtained. Statistical evaluation used 95% limits of agreement and linear regression analysis. CAD correlated well with diffusing capacity (DL CO ) (R=-0.531, P CO (R=-0.705, P CO and moderately with FVC (DL CO : R=-0.663; FVC: R=-0.436; P≤0.005). The CAD system is a promising tool for ILD quantification, showing close correlation with human observers and physiologic impairment. (orig.)

  3. Research on a Pulmonary Nodule Segmentation Method Combining Fast Self-Adaptive FCM and Classification

    Directory of Open Access Journals (Sweden)

    Hui Liu

    2015-01-01

    Full Text Available The key problem of computer-aided diagnosis (CAD of lung cancer is to segment pathologically changed tissues fast and accurately. As pulmonary nodules are potential manifestation of lung cancer, we propose a fast and self-adaptive pulmonary nodules segmentation method based on a combination of FCM clustering and classification learning. The enhanced spatial function considers contributions to fuzzy membership from both the grayscale similarity between central pixels and single neighboring pixels and the spatial similarity between central pixels and neighborhood and improves effectively the convergence rate and self-adaptivity of the algorithm. Experimental results show that the proposed method can achieve more accurate segmentation of vascular adhesion, pleural adhesion, and ground glass opacity (GGO pulmonary nodules than other typical algorithms.

  4. A patient who sufferred pulmonary tuberculosis with syndrome of inappropriate secretion of antidiuretic hormone, after radiotherapy for pulmonary adenocarcinoma

    International Nuclear Information System (INIS)

    Kobayashi, Kashin; Horiguchi, Takahiko; Hata, Hideharu; Sasaki, Yasushi; Hirose, Masahiro; Shiga, Mamoru; Kondo, Rieko; Tachikawa, Souichi

    2007-01-01

    A 62-year-old man presented in June 2006 with right thoracic pain, cough, and weight loss, which had persisted for 3 months. Chest X-ray showed a mass-like shadow in the right pulmonary apex, suggesting a stage IIIb adenocarcinoma which was confirmed by biopsy. We gave a total radiation dose of 60 Gy, after this which general malaise and weakness were noted. The results of endocrinological examinations suggested syndrome of inappropriate antidiuretic hormone secretion (SIADH). Thoracic CT showed ground-glass opacity (GGO) in both lungs, and we could not rule out pulmonary tuberculosis. A sputum was positive for acid-fast stain and polymerase polymerase chain reaction-Tuberculosa (PCR-Tb), suggesting that SIADH was associated with pulmonary tuberculosis. Water restriction, i.v. physiological saline, and anti-tuberculosis therapy relieved hyponatremia and the symptoms. (author)

  5. Early prediction of lung cancer recurrence after stereotactic radiotherapy using second order texture statistics

    Science.gov (United States)

    Mattonen, Sarah A.; Palma, David A.; Haasbeek, Cornelis J. A.; Senan, Suresh; Ward, Aaron D.

    2014-03-01

    Benign radiation-induced lung injury is a common finding following stereotactic ablative radiotherapy (SABR) for lung cancer, and is often difficult to differentiate from a recurring tumour due to the ablative doses and highly conformal treatment with SABR. Current approaches to treatment response assessment have shown limited ability to predict recurrence within 6 months of treatment. The purpose of our study was to evaluate the accuracy of second order texture statistics for prediction of eventual recurrence based on computed tomography (CT) images acquired within 6 months of treatment, and compare with the performance of first order appearance and lesion size measures. Consolidative and ground-glass opacity (GGO) regions were manually delineated on post-SABR CT images. Automatic consolidation expansion was also investigated to act as a surrogate for GGO position. The top features for prediction of recurrence were all texture features within the GGO and included energy, entropy, correlation, inertia, and first order texture (standard deviation of density). These predicted recurrence with 2-fold cross validation (CV) accuracies of 70-77% at 2- 5 months post-SABR, with energy, entropy, and first order texture having leave-one-out CV accuracies greater than 80%. Our results also suggest that automatic expansion of the consolidation region could eliminate the need for manual delineation, and produced reproducible results when compared to manually delineated GGO. If validated on a larger data set, this could lead to a clinically useful computer-aided diagnosis system for prediction of recurrence within 6 months of SABR and allow for early salvage therapy for patients with recurrence.

  6. Thin-section computed tomography findings in 104 immunocompetent patients with adenovirus pneumonia.

    Science.gov (United States)

    Park, Chan Kue; Kwon, Hoon; Park, Ji Young

    2017-08-01

    Background To date, there has been no computed tomography (CT) evaluation of adenovirus pneumonia in a large number of immunocompetent patients. Purpose To describe the thin-section CT findings of immunocompetent patients with adenovirus pneumonia. Material and Methods We prospectively enrolled 104 patients with adenovirus pneumonia from a military hospital. CT scans of each patient were retrospectively and independently assessed by two radiologists for the presence of abnormalities, laterality and zonal predominance of the parenchymal abnormalities, and dominant imaging patterns and their anatomic distributions. Results CT findings included consolidation (n = 92), ground-glass opacity (GGO; n = 82), septal thickening (n = 34), nodules (n = 46), bronchial wall thickening (n = 32), pleural effusion (n = 16), and lymphadenopathy (n = 3). Eighty-four patients (81%) exhibited unilateral parenchymal abnormalities and 57 (57%) exhibited lower lung zone abnormalities. The most frequently dominant CT pattern was consolidation with surrounding GGO (n = 50), with subpleural (70%) and peribronchovascular (94%) distributions. Consolidation-the second-most common pattern (n = 33)-also exhibited subpleural (79%) and peribronchovascular (97%) distributions. The dominant nodule pattern (n = 14) exhibited mixed (64%) and peribronchovascular (100%) distributions. A dominant GGO pattern was only observed in four patients; none had central distribution. Conclusion Although the manifestations of adenovirus pneumonia on CT are varied, we found the most frequent pattern was consolidation with or without surrounding GGO, with subpleural and peribronchovascular distributions. Parenchymal abnormalities were predominantly unilateral and located in the lower lung zone. If dominant consolidation findings are present in immunocompetent patients during the early stages, adenovirus pneumonia should be considered.

  7. Adenocarcinoma of the lung with scattered consolidation: radiological-pathological correlation and prognosis.

    Science.gov (United States)

    Jiang, Binghu; Takashima, Shodayu; Hakucho, Tomoaki; Hodaka, Numasaki; Yasuhiko, Tomita; Masahiko, Higashiyama

    2013-10-01

    To investigate the clinicopathological features and prognosis in patients with adenocarcinoma of the lung with scattered consolidation (ALSC). Between January 2006 and March 2010, 139 consecutive patients with lung adenocarcinoma of ≤3 cm, who underwent pulmonary resection for lung cancer, were investigated retrospectively. Radiologic classification was based on the findings of thin-section CT such as the presence of consolidation or ground-glass opacity (GGO). Type I (n=15) and Type II (n=14), showed a pure GGO and a mixed GGO with consolidation <50%, respectively. Type IV (n=38) and Type V (n=52) showed a mixed GGO with consolidation ≥50% and a pure consolidation, respectively. Type III (n=20) was the adenocarcinoma of the lung with scattered consolidation (ALSC). The clinicopathological features and prognosis of ALSC was investigated with comparative analysis and survival analysis. Because of the similar recurrence rate for Type I and Type II (P=1.000), Type IV and Type V (P=0.343), we merged Type I and Type II as Type I+II, Type IV and Type V as Type IV+V, respectively. In the 20 (14.4%) patients with ALSC, lymph node metastasis was not observed, and it was rare in lymphatic invasion and vascular invasion. On the basis of IASLC/ATS/ERS 2011 classification, 80% of the ALSC were preinvasive lesions. In Noguchi classification, there was no significant difference between Type I+II and ALSC (P=0.260). The prognosis of ALSC was similar to Type I+II (P=0.408), but better than Type IV+V (P=0.040). Adenocarcinoma of the lung with scattered consolidation (ALSC) on thin-section CT was a relatively favorable prognostic factor. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  8. Detailed-term-accounting approximation calculations of the radiative opacity of aluminum plasmas: A systematic study

    International Nuclear Information System (INIS)

    Zeng Jiaolong; Yuan Jianmin

    2002-01-01

    The spectrally resolved radiative opacity and the Rosseland and Planck mean opacities are calculated by using the detailed-term-accounting approximation for aluminum plasmas with varieties of density and temperature. The results are presented along a 40 eV isothermal sequence, a 0.01 g/cm 3 isodense sequence, and a sequence with average ionization degree Z*∼7.13. Particular attention is given to the influence of the detailed treatment of spectral lines on the Rosseland mean opacity under different thermodynamical conditions. The results show that at densities of 0.004 g/cm 3 and higher, the opacities are not very sensitive to the spectral linewidth within a reasonable range. As examples, the Rosseland mean opacity, which is most sensitive to the detailed linewidth, at 40 eV and 0.004 g/cm 3 changes no more than 15%, when we change the electron impact spectral linewidth artificially by reducing it by 50% or increasing it twice, and at 40 eV and 0.1 g/cm 3 it changes less than 5%. For comparison, we also carried out calculations by using an average atom model. For the Rosseland mean opacities, the two models show quite large differences, in particular at low densities, while for the Planck mean opacities the results of the two models are much closer

  9. Perilaku Pemustaka Dalam Temu Kembali Koleksi Dengan Menggunakan OPAC Berbasis SLIMS

    Directory of Open Access Journals (Sweden)

    Mujiati Mujiati

    2014-07-01

    Full Text Available Abstract: An  increase of  library collection and  information explosion causes  problems  on    information  retrieval  for  library  users.  Those explosion will be helpful for users using Online Public Access Catalog (OPAC. This article tries to explore the use of OPAC based SLIMs on STAIN Ponorogo  library. OPAC proves  to help users  on  retrieval  be easier and faster, beside its obstacles

  10. Influence of detector collimation and beam pitch for identification and image quality of ground-glass attenuation and nodules on 16- and 64-detector row CT systems: experimental study using chest phantom.

    Science.gov (United States)

    Ohno, Yoshiharu; Koyama, Hisanobu; Kono, Astushi; Terada, Mari; Inokawa, Hiroyasu; Matsumoto, Sumiaki; Sugimura, Kazuro

    2007-12-01

    The purpose of the present study was to determine the influence of detector collimation and beam pitch for identification and image quality of ground-glass attenuation (GGA) and nodules on 16- and 64-detector row CTs, by using a commercially available chest phantom. A chest CT phantom including simulated GGAs and nodules was scanned with different detector collimations, beam pitches and tube currents. The probability and image quality of each simulated abnormality was visually assessed with a five-point scoring system. ROC-analysis and ANOVA were then performed to compare the identification and image quality of either protocol with standard values. Detection rates of low-dose CTs were significantly reduced when tube currents were set at 40mA or less by using detector collimation 16 and 64x0.5mm and 16 and 32mmx1.0mm for low pitch, and at 100mA or less by using detector collimation 16 and 64x0.5mm and 16 and 32mmx1.0mm for high pitch (pdetector collimation 16 and 64x0.5mm and 16 and 32x1.0mm for low pitch, and at 150mA or less by using detector collimation 16 and 64x0.5mm and 16 and 32x1.0mm for high pitch (pDetector collimation and beam pitch were important factors for the image quality and identification of GGA and nodules by 16- and 64-detector row CT.

  11. Caecal cancer presenting as leg erythema and a lung opacity.

    Science.gov (United States)

    Das, Archik; Hureibi, Khalid; Tayyab, Muhammad; McCullough, Peter

    2017-09-07

    Necrotising infection of the lower limb is a rare presentation for colorectal malignancy. We report a case of a perforated caecal adenocarcinoma presenting with right leg erythema, pain and swelling in the presence of a right lower lobe lung opacity. Following initial debridement and washout, CT imaging demonstrated a thickened terminal ileum, caecum and appendix, in keeping with primary malignancy. This fed the right-sided lower limb sepsis tracking down from the medial aspect of the psoas muscle to give rise to the multiloculated collection seen in the adductor compartment. The lung lesion measured 16 mm and was metastatic. The patient was successfully managed with a subtotal colectomy and an end ileostomy. The biopsy confirmed an adenocarcinoma (T4N1M1). We highlight the importance of perforated colonic carcinoma as a leading differential for lower limb abscesses. Suspicions should be raised further if accompanied by rounded opacifications on plain film radiography of the lungs. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  12. Proving Opacity of Transactional Memory with Early Release

    Directory of Open Access Journals (Sweden)

    Siek Konrad

    2015-12-01

    Full Text Available Transactional Memory (TM is an alternative way of synchronizing concurrent accesses to shared memory by adopting the abstraction of transactions in place of low-level mechanisms like locks and barriers. TMs usually apply optimistic concurrency control to provide a universal and easy-to-use method of maintaining correctness. However, this approach performs a high number of aborts in high contention workloads, which can adversely affect performance. Optimistic TMs can cause problems when transactions contain irrevocable operations. Hence, pessimistic TMs were proposed to solve some of these problems. However, an important way of achieving efficiency in pessimistic TMs is to use early release. On the other hand, early release is seemingly at odds with opacity, the gold standard of TM safety properties, which does not allow transactions to make their state visible until they commit. In this paper we propose a proof technique that makes it possible to demonstrate that a TM with early release can be opaque as long as it prevents inconsistent views.

  13. Opacity and noninear effects on theoretical BL Herculis models

    International Nuclear Information System (INIS)

    Hodson, S.W.; Cox, A.N.; King, D.S.

    1982-01-01

    Linear and nonlinear pulsation models for BL Herculis variables have been constructed to investigate the resonance which seems to occur when the ratio of the second overtone (Pi 2 ) to fundamental (Pi 0 ) radial periods is near 0.5. This resonance is shown to affect the shapes of the light and velocity curves and produce bumps on either ascending or descending light just as far classical Cepheids. Linear theory predicts the resonance to occur at periods between 1.7 and 3.0 days for 0.55 M/sub sun/ and between 2.1 and 4.0 days for 0.75 M/sub sun/ stars at the red and blue edges, respectively, of the stability strip. These periods are rather independent of the composition and opacity tables. However, observations show the resonance to be about 1.7 days for all BL Her variables by noticing that the bump phase switches from descending to ascending light as the period increases. Nonlinear calculations indicate that the linear theory predictions of Pi 2 /Pi 0 are not reliable just at Pi 2 /Pi 0 = 0.5, and the predicted resonance occurs always at the proper period as observed

  14. The initial appearance of lung adenocarcinoma on computed tomography

    International Nuclear Information System (INIS)

    Saito, Haruhiro; Yamada, Kozo; Suzuki, Rie; Oshita, Fumihiro; Nakayama, Haruhiko; Mitsuda, Aki; Kameda, Youichi; Noda, Kazumasa

    2002-01-01

    The purpose of this study was to determine the initial appearance of lung adenocarcinoma on computed tomography and the appropriate follow-up duration. Retrospective review of 17 cases in which computed tomography (CT) of the chest was performed about 2 years prior to the diagnosis of lung cancer. The diagnosis was confirmed by surgical resection in all cases. The lung cancers were divided into four types based on their appearance on the initial CT: ground-glass opacity (GGO)-like images in which the lesion appeared as a faint opacity, BLA (bubble-like appearance) image, in which the lesion resembled a focal collection of air, a small solitary nodule, and a scar-like image. Vascular involvement, air-bronchogram, and pleural indentation were all more prominent during a serial scan obtained just prior to surgery than on the initial scan. An increase in vascular involvement occurred prior to the other changes. High attenuation areas appeared in the GGO-like lesions prior to an increase in the size of the lesion. The growth pattern was classified as slow growing, rapidly growing, and initially slow growing with accelerated growth. The doubling time was similar in lesions with the same appearance. This information can be used to guide follow-up of images suspected of lung cancer. The appropriate follow-up duration is estimated from 6 to 12 months for GGO and BLA-like images, and from 2 to 3 months for small solitary nodules. The biological behavior of lung cancer is reflected in their initial appearance on CT. (author)

  15. Large Enhancement in High-Energy Photoionization of Fe XVII and Missing Continuum Plasma Opacity

    Science.gov (United States)

    Nahar, Sultana N.; Pradhan, Anil K.

    2016-06-01

    Aimed at solving the outstanding problem of solar opacity, and radiation transport plasma models in general, we report substantial photoabsorption in the high-energy regime due to atomic core photoexcitations not heretofore considered. In extensive R -matrix calculations of unprecedented complexity for an important iron ion Fe xvii (Fe16 + ), with a wave function expansion of 99 Fe xviii (Fe17 + ) LS core states from n ≤4 complexes (equivalent to 218 fine structure levels), we find (i) up to orders of magnitude enhancement in background photoionization cross sections, in addition to strongly peaked photo-excitation-of-core resonances not considered in current opacity models, and ii) demonstrate convergence with respect to successive core excitations. The resulting increase in the monochromatic continuum, and 35% in the Rosseland mean opacity, are compared with the "higher-than-predicted" iron opacity measured at the Sandia Z -pinch fusion device at solar interior conditions.

  16. A Rare Form of Corneal Opacity Associated with Spondyloepiphyseal Dysplasia Congenita

    Directory of Open Access Journals (Sweden)

    Yuichiro Ishida

    2018-02-01

    Full Text Available A 13-year-old Japanese female diagnosed with spondyloepiphyseal dysplasia congenita (SEDC was referred for ophthalmologic evaluation. Examination with slit-lamp and optical coherence tomography revealed bilateral thin cornea with diffuse corneal opacity which was localised at the posterior stromal depth in the central cornea. Unlike the two previously reported cases of diffuse and nodular patterns of corneal opacity in SEDC, the current case exhibited a rare form of corneal opacity. SEDC is one of the type II collagenopathies, characterised by dwarfism because the mutations in COL2A1 prevent bone growth. Although the existence of type II collagen has not been reported in the human corneal stroma, the aetiology of the opacity in the corneal stroma in SEDC type II collagenopathy is of interest.

  17. Non-LTE H2+ as the source of missing opacity in the solar atmosphere

    Science.gov (United States)

    Swamy, K. S. K.; Stecher, T. P.

    1974-01-01

    The population of the various vibrational levels of the H2+ molecule has been calculated from the consideration of formation and destruction mechanisms. The resulting population is used in calculating the total absorption due to H2+ and is compared with the other known sources of opacity at several optical depths of the solar atmosphere. It is shown that the absorption due to H2+ can probably account for the missing ultraviolet opacity in the solar atmosphere.

  18. Free-free opacity in dense plasmas with an average atom model

    International Nuclear Information System (INIS)

    Shaffer, Nathaniel R.; Ferris, Natalie G.; Colgan, James Patrick; Kilcrease, David Parker; Starrett, Charles Edward

    2017-01-01

    A model for the free-free opacity of dense plasmas is presented. The model uses a previously developed average atom model, together with the Kubo-Greenwood model for optical conductivity. This, in turn, is used to calculate the opacity with the Kramers-Kronig dispersion relations. Furthermore, comparisons to other methods for dense deuterium results in excellent agreement with DFT-MD simulations, and reasonable agreement with a simple Yukawa screening model corrected to satisfy the conductivity sum rule.

  19. Computational Design of Short Pulse Laser Driven Iron Opacity Measurements at Stellar-Relevant Conditions

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Madison E. [Univ. of Florida, Gainesville, FL (United States)

    2017-05-20

    Opacity is a critical parameter in the simulation of radiation transport in systems such as inertial con nement fusion capsules and stars. The resolution of current disagreements between solar models and helioseismological observations would bene t from experimental validation of theoretical opacity models. Overall, short pulse laser heated iron experiments reaching stellar-relevant conditions have been designed with consideration of minimizing tamper emission and optical depth effects while meeting plasma condition and x-ray emission goals.

  20. Epistemic Opacity, Confirmation Holism and Technical Debt: Computer Simulation in the Light of Empirical Software Engineering

    OpenAIRE

    Newman , Julian

    2015-01-01

    Epistemic opacity vis a vis human agents has been presented as an essential, ineliminable characteristic of computer simulation models resulting from the characteristics of the human cognitive agent. This paper argues, on the contrary, that such epistemic opacity as does occur in computer simulations is not a consequence of human limitations but of a failure on the part of model developers to adopt good software engineering practice for managing human error and ensuring the software artefact ...

  1. How the machine ‘thinks’: Understanding opacity in machine learning algorithms

    Directory of Open Access Journals (Sweden)

    Jenna Burrell

    2016-01-01

    Full Text Available This article considers the issue of opacity as a problem for socially consequential mechanisms of classification and ranking, such as spam filters, credit card fraud detection, search engines, news trends, market segmentation and advertising, insurance or loan qualification, and credit scoring. These mechanisms of classification all frequently rely on computational algorithms, and in many cases on machine learning algorithms to do this work. In this article, I draw a distinction between three forms of opacity: (1 opacity as intentional corporate or state secrecy, (2 opacity as technical illiteracy, and (3 an opacity that arises from the characteristics of machine learning algorithms and the scale required to apply them usefully. The analysis in this article gets inside the algorithms themselves. I cite existing literatures in computer science, known industry practices (as they are publicly presented, and do some testing and manipulation of code as a form of lightweight code audit. I argue that recognizing the distinct forms of opacity that may be coming into play in a given application is a key to determining which of a variety of technical and non-technical solutions could help to prevent harm.

  2. The effect of Livermore OPAL opacities on the evolutionary masses of RR Lyrae stars

    Science.gov (United States)

    Yi, Sukyoung; Lee, Young-Wook; Demarque, Pierre

    1993-01-01

    We have investigated the effect of the new Livermore OPAL opacities on the evolution of horizontal-branch (HB) stars. This work was motivated by the recent stellar pulsation calculations using the new Livermore opacities, which suggest that the masses of double-mode RR Lyrae stars are 0.1-0.2 solar mass larger than those based on earlier opacities. Unlike the pulsation calculations, we find that the effect of opacity change on the evolution of HB stars is not significant. In particular, the effect of the mean masses of RR Lyrae stars is very small, showing a decrease of only 0.01-0.02 solar mass compared to the models based on old Cox-Stewart opacities. Consequently, with the new Livermore OPAL opacities, both the stellar pulsation and evolution models now predict approximately the same masses for the RR Lyrae stars. Our evolutionary models suggest that the mean masses of the RR Lyrae stars are about 0.76 and about 0.71 solar mass for M15 (Oosterhoff group II) and M3 (group I), respectively. If (alpha/Fe) = 0.4, these values are decreased by about 0.03 solar mass. Variations of the mean masses of RR Lyrae stars with HB morphology and metallicity are also presented.

  3. Comparison of Fe and Ni opacity calculations for a better understanding of pulsating stellar envelopes

    International Nuclear Information System (INIS)

    Gilles, D.; Turck-Chieze, S.; Loisel, G.; Piau, L.; Ducret, J.E.; Poirier, M.; Blenski, T.; Thais, F.; Blancard, C.; Cosse, P.; Faussurier, G.; Gilleron, F.; Pain, J.C.; Porcherot, Q.; Guzik, J.A.; Kilcrease, D.P.; Magee, N.H.; Harris, J.; Busquet, M.; Delahaye, F.; Zeippen, C.J.; Bastiani-Ceccotti, S.

    2011-01-01

    Opacity is an important ingredient of the evolution of stars. The calculation of opacity coefficients is complicated by the fact that the plasma contains partially ionized heavy ions that contribute to opacity dominated by H and He. Up to now, the astrophysical community has greatly benefited from the work of the contributions of Los Alamos, Livermore and the Opacity Project (OP). However unexplained differences of up to 50% in the radiative forces and Rosseland mean values for Fe have been noticed for conditions corresponding to stellar envelopes. Such uncertainty has a real impact on the understanding of pulsating stellar envelopes, on the excitation of modes, and on the identification of the mode frequencies. Temperature and density conditions equivalent to those found in stars can now be produced in laboratory experiments for various atomic species. Recently the photo-absorption spectra of nickel and iron plasmas have been measured during the LULI 2010 campaign, for temperatures between 15 and 40 eV and densities of similar to 3 mg/cm 3 . A large theoretical collaboration, the 'OPAC', has been formed to prepare these experiments. We present here the set of opacity calculations performed by eight different groups for conditions relevant to the LULI 2010 experiment and to astrophysical stellar envelope conditions. (authors)

  4. Development on the National Ignition Facility of a High Energy Density Opacity Platform

    Energy Technology Data Exchange (ETDEWEB)

    Perry, Theodore Sonne [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dodd, Evan S. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); DeVolder, Barbara Gloria [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Johns, Heather Marie [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Cardenas, Tana [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Archuleta, Thomas Nick [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Kline, John L. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Flippo, Kirk Adler [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Vinyard, Natalia Sergeevna [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Sherrill, Manolo Edgar [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Wilde, Bernhard Heinz [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Tregillis, Ian Lee [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Urbatsch, Todd James [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Douglas, Melissa Rae [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Heeter, R. F. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Liedahl, D. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Wilson, B. G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Iglesias, C. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Schneider, M. B. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Martin, M. E. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); London, R. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Ahmed, M. F. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Thompson, N. B. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Emig, J. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Zika, M. R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Opachich, Y. P. [Nevada National Security Site (NNSS), NV (United States); King, J. A. [Nevada National Security Site (NNSS), NV (United States); Ross, P. W. [Nevada National Security Site (NNSS), NV (United States); Huffman, E. J. [Nevada National Security Site (NNSS), NV (United States); Knight, R. A. [Nevada National Security Site (NNSS), NV (United States); Koch, J. A. [Nevada National Security Site (NNSS), NV (United States); Pond, T. D. [Nevada National Security Site (NNSS), NV (United States); Craxton, R. S. [Univ. of Rochester, NY (United States). Lab. for Laser Energetics; Zhang, R. [Univ. of Rochester, NY (United States). Lab. for Laser Energetics; McKenty, P. W. [Univ. of Rochester, NY (United States). Lab. for Laser Energetics; Garcia, E. M. [Univ. of Rochester, NY (United States). Lab. for Laser Energetics; Bailey, J. E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Rochau, G. A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Hansen, S. B. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-10-02

    X-ray opacity is a crucial factor in all radiation-hydrodynamics calculations, yet it is one of the least validated of the material properties in simulation codes for high-energy-density plasmas. Recent opacity experiments at the Sandia Z-machine have shown up to factors of two discrepancies between theory and experiment for various mid-Z elements (Fe, Cr, Ni). These discrepancies raise doubts regarding the accuracy of the opacity models which are used in ICF and stewardship as well as in astrophysics. Therefore, a new experimental opacity platform has been developed on the National Ignition Facility (NIF), not only to verify the Z-machine experimental results, but also to extend the experiments to other temperatures and densities. Within the context of the national opacity strategy, the first NIF experiments were directed towards measuring the opacity of iron at a temperature of ~160 eV and an electron density of ~7xl021 cm-3(Anchor 1). The Z data agree with theory at these conditions, providing a reference point for validation of the NIF platform. Development shots on NIF have demonstrated the ability to create a sufficiently bright point backlighter using an imploding plastic capsule, and also a combined hohlraum, sample and laser drive able to produce iron plasmas at the desired conditions. Spectrometer qualification has been completed, albeit with additional improvements planned, and the first iron absorption spectra have now been obtained.

  5. Functional characterization of antibodies against Neisseria gonorrhoeae opacity protein loops.

    Directory of Open Access Journals (Sweden)

    Jessica G Cole

    2009-12-01

    Full Text Available The development of a gonorrhea vaccine is challenged by the lack of correlates of protection. The antigenically variable neisserial opacity (Opa proteins are expressed during infection and have a semivariable (SV and highly conserved (4L loop that could be targeted in a vaccine. Here we compared antibodies to linear (Ab(linear and cyclic (Ab(cyclic peptides that correspond to the SV and 4L loops and selected hypervariable (HV(2 loops for surface-binding and protective activity in vitro and in vivo.Ab(SV cyclic bound a greater number of different Opa variants than Ab(SV linear, including variants that differed by seven amino acids. Antibodies to the 4L peptide did not bind Opa-expressing bacteria. Ab(SV (cyclic and Ab(HV2 (cyclic, but not Ab(SV (linear or Ab(HV2 linear agglutinated homologous Opa variants, and Ab(HV2BD (cyclic but not Ab(HV2BD (linear blocked the association of OpaB variants with human endocervical cells. Only Ab(HV2BD (linear were bactericidal against the serum resistant parent strain. Consistent with host restrictions in the complement cascade, the bactericidal activity of Ab(HV2BD (linear was increased 8-fold when rabbit complement was used. None of the antibodies was protective when administered vaginally to mice. Antibody duration in the vagina was short-lived, however, with <50% of the antibodies recovered 3 hrs post-administration.We conclude that an SV loop-specific cyclic peptide can be used to induce antibodies that recognize a broad spectrum of antigenically distinct Opa variants and have agglutination abilities. HV(2 loop-specific cyclic peptides elicited antibodies with agglutination and adherence blocking abilities. The use of human complement when testing the bactericidal activity of vaccine-induced antibodies against serum resistant gonococci is also important.

  6. OPACs en Web: entre la tradición y la innovación = OPACs on the Web: Between tradition and innovation

    Directory of Open Access Journals (Sweden)

    Purificación Moscoso

    2002-06-01

    Full Text Available El desarrollo de Internet ha impulsado la implementación de OPACs en este entorno. Se analizan los cambios que estos nuevos OPACs suponen en cuanto a: estructura, gestión y mantenimiento del catálogo; sistemas de recuperación e interfaz del usuario. La pervivencia de prácticas tradicionales en la estructura y organización de la información impide que se les considere una herramienta innovadora. Se estudia la estructura de la base de datos, así como los principios tradicionales que rigen su elaboración. Se analizan las repercusiones que lleva consigo seguir utilizando reglas y formatos diseñados para un entorno manual que nada tiene que ver con el nuevo entorno tecnológico en el que hoy en día nos movemos = Internet development has driven the implementation of OPACs in that environment. Changes of these new OPACs as referred to catalog structure, management, and maintenance, retrieval systems and user interface are analyzed. The survival of traditional practices in the information structure and organization avoids them to be considered an innovative tool. The database structure is studied as well as the traditional principles that govern their elaboration. Effects of keeping using rules and formats designed for a manual environment, which is absolutely different from the present day technological environment are analyzed.

  7. OPACs en Web: entre la tradición y la innovación OPACs on the Web: Between tradition and innovation

    Directory of Open Access Journals (Sweden)

    Purificación Moscoso

    2002-06-01

    Full Text Available El desarrollo de Internet ha impulsado la implementación de OPACs en este entorno. Se analizan los cambios que estos nuevos OPACs suponen en cuanto a: estructura, gestión y mantenimiento del catálogo; sistemas de recuperación e interfaz del usuario. La pervivencia de prácticas tradicionales en la estructura y organización de la información impide que se les considere una herramienta innovadora. Se estudia la estructura de la base de datos, así como los principios tradicionales que rigen su elaboración. Se analizan las repercusiones que lleva consigo seguir utilizando reglas y formatos diseñados para un entorno manual que nada tiene que ver con el nuevo entorno tecnológico en el que hoy en día nos movemos.Internet development has driven the implementation of OPACs in that environment. Changes of these new OPACs as referred to catalog structure, management, and maintenance, retrieval systems and user interface are analyzed. The survival of traditional practices in the information structure and organization avoids them to be considered an innovative tool. The database structure is studied as well as the traditional principles that govern their elaboration. Effects of keeping using rules and formats designed for a manual environment, which is absolutely different from the present day technological environment are analyzed.

  8. IRON OPACITY BUMP CHANGES THE STABILITY AND STRUCTURE OF ACCRETION DISKS IN ACTIVE GALACTIC NUCLEI

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Yan-Fei [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Davis, Shane W. [Department of Astronomy, University of Virginia, P.O. Box 400325, Charlottesville, VA 22904-4325 (United States); Stone, James M. [Department of Astrophysical Sciences, Princeton University, Princeton, NJ 08544 (United States)

    2016-08-10

    Accretion disks around supermassive black holes have regions where the Rosseland mean opacity can be larger than the electron scattering opacity due to the large number of bound–bound transitions in iron. We study the effects of this iron opacity “bump” on the thermal stability and vertical structure of radiation-pressure-dominated accretion disks, utilizing three-dimensional radiation magnetohydrodynamic (MHD) simulations in the local shearing box approximation. The simulations self-consistently calculate the heating due to MHD turbulence caused by magneto-rotational instability and radiative cooling by using the radiative transfer module based on a variable Eddington tensor in Athena. For a 5 × 10{sup 8} solar mass black hole with ∼3% of the Eddington luminosity, a model including the iron opacity bump maintains its structure for more than 10 thermal times without showing significant signs of thermal runaway. In contrast, if only electron scattering and free–free opacity are included as in the standard thin disk model, the disk collapses on the thermal timescale. The difference is caused by a combination of (1) an anti-correlation between the total optical depth and the midplane pressure, and (2) enhanced vertical advective energy transport. These results suggest that the iron opacity bump may have a strong impact on the stability and structure of active galactic nucleus (AGN) accretion disks, and may contribute to a dependence of AGN properties on metallicity. Since this opacity is relevant primarily in UV emitting regions of the flow, it may help to explain discrepancies between observation and theory that are unique to AGNs.

  9. The influence of urban area opacity on biologically active UV-B irradiance

    Science.gov (United States)

    Chubarova, Nataly; Rozental', Victor

    2013-04-01

    The study of UV irradiance changes in urban area is an essential problem due to the significant effect of UV irradiance on human health which can be positive (vitamin D synthesis) and negative (erythema, skin cancer, eye damage). According to the results of several experiments within the Moscow megacity we studied the effects of urban area opacity on the different types of biologically active UV-B irradiance on the base of a specially developed mobile photometric complex snd additional measurements of the urban opacity by Nikon Fisheye Converter FC-E8. We analyzed both the level of erythemally-active irradiance and the UV eye damaging radiation using the broadband UVB-1 YES pyranometer calibrated against ultraviolet spectroradiometer Bentham DTM-300 of the Medical University of Innsbruck (courtesy of Dr. M.Blumthaler). In order to estimate the effects of the urban opacity the measurements were normalized on similar measurements at the Meteorological Observatory of Moscow State University with zero opacity. This ratio is defined as an urban radiative transmittance (URT). Different atmospheric conditions were considered. In cloudy conditions the effect of opacity on URT is much less than that in conditions when the sun disk is open from clouds. We revealed some spectral features in transmittance of biologically active UV-B irradiance which is characterized by higher URT variations in overcast cloudy conditions due to more intensive scattering and smaller direct solar radiation component. In the absence of cloudiness the effect of opacity was studied for open and screening solar disk conditions. We obtained much higher URT in UVB spectral region compared with that for total solar irradiance for screening solar disk conditions with a significant URT dependence on the opacity only in UVB spectral region. No URT dependence was obtained for total solar irradiance in these conditions. Some model calculations were fulfilled to match the experimental results.

  10. Presenting a model for display and user interface specifications of web based OPACs on the basis of available universal standards and experts views in order to compare the Iranian library and information centers OPACs

    OpenAIRE

    Zavaraqi, Rasoul

    2005-01-01

    The aim of this study is to present a model for display and user interface specifications of web-based OPACs on the basis of available universal standards and experts’ views in order to compare the present Iranian library and information centers OPACs. Three method were used for data collection in this research: literature review, survey of opinions by means of a checklist, and evaluation of the available web-based OPACs. The community of Iranian experts in OPAC issues and all of 6 available ...

  11. Night and Day: The Opacity of Clouds Measured by the Mars Orbiter Laser Altimeter (MOLA)

    Science.gov (United States)

    Neumann, G. A.; Wilson, R. J.

    2006-01-01

    The Mars Orbiter Laser Altimeter (MOLA) [l] on the Mars Global Surveyor spacecraft ranged to clouds over the course of nearly two Mars years [2] using an active laser ranging system. While ranging to the surface, the instrument was also able to measure the product of the surface reflectivity with the two-way atmospheric transmission at 1064 nm. Furthermore, the reflectivity has now been mapped over seasonal cycles using the passive radiometric capability built into MOLA [3]. Combining these measurements, the column opacity may be inferred. MOLA uniquely provides these measurements both night and day. This study examines the pronounced nighttime opacity of the aphelion season tropical water ice clouds, and the indiscernibly low opacity of the southern polar winter clouds. The water ice clouds (Figure 1) do not themselves trigger the altimeter but have measured opacities tau > 1.5 and are temporally and spatially correlated with temperature anomalies predicted by a Mars Global Circulation Model (MGCM) that incorporates cloud radiative effects [4]. The south polar CO2 ice clouds trigger the altimeter with a very high backscatter cross-section over a thickness of 3-9 m and are vertically dispersed over several km, but their total column opacities lie well below the MOLA measurement limit of tau = 0.7. These clouds correspond to regions of supercooled atmosphere that may form either very large specularly reflecting particles [2] or very compact, dense concentrations (>5x10(exp 6)/cu m) of 100-p particles

  12. Iron and Nickel spectral opacity calculations in conditions relevant for pulsating stellar envelopes and experiments

    International Nuclear Information System (INIS)

    Gilles, D.; Turck-Chieze, S.; Busquet, M.; Thais, F.; Loisel, G.; Piau, L.; Ducret, J. E.; Blenski, T.; Blancard, C.; Cosse, P.; Faussurier, G.; Gilleron, F.; Pain, J. C.; Porcherot, Q.; Guzik, J. A.; Kilcrease, D. P.; Magee, N. H.; Harris, J.; Bastiani-Ceccotti, S.; Delahaye, F.; Zeippen, C. J.

    2013-01-01

    Seismology of stars is strongly developing. To address this question we have formed an international collaboration, OPAC, to perform specific experimental measurements, compare opacity calculations, and improve the opacity calculations in stellar codes [1]. We consider the following opacity codes: SCO, CASSANDRA, STA, OPAS, LEDCOP, OP, SCO-RCG. Their comparison has shown large differences for Fe and Ni in equivalent conditions of envelopes of type II supernova precursors, temperatures between 15 and 40 eV and densities of a few mg/cm 3 [2-4]. LEDCOP, OPAS, SCO-RCG structure codes and STA give similar results and differ from OP ones for the lower temperatures and for spectral interval values [3]. In this work we discuss the role of Configuration Interaction (CI) and the influence of the number of used configurations. We present and include in the opacity code comparisons new HULLAC-v9 calculations [5, 6] that include full CI. To illustrate the importance of this effect we compare different CI approximations (modes) available in HULLAC-v9 [7]. These results are compared to previous predictions and to experimental data. Differences with OP results are discussed. (authors)

  13. Recent status and supplementary review of lenticular opacities in proximally exposed A-bomb survivors

    Energy Technology Data Exchange (ETDEWEB)

    Sugimoto, S [Sugimoto Ophthalmic Hospital, Hiroshima (Japan)

    1978-04-01

    A review was made on the progress of lenticular opacities in proximally exposed A-bomb survivors on the basis of three experimental cases. A-bomb cataract is the first late effect of A-bomb radiation which appeared in A-bomb survivors and is the only disorder which can still be visualized at the present time. We have therefore continued to use this as one major evidence that A-bomb injuries have not been cured in spite of our for a complete ban of nuclear weapons. According to the findings of lenticular opacities of typical A-bomb cataract observed in experimental cases, there was in some cases after a latent period progression of opacities from several years to more than 10 years followed by a gradual decrease in opacities, whereas in some cases there was after a latent period a remarkable progress in opacities for several years followed by a marked decrease in the lesions. At the present time there is no evidence of progression and it appears that the progression has ceased. Incipient senile cataract which developed concurrently has completely no transitional relationship to A-bomb cataract and appears to progress slowly but steadily.

  14. Recent status and supplementary review of lenticular opacities in proximally exposed A-bomb survivors

    International Nuclear Information System (INIS)

    Sugimoto, Shigenori

    1978-01-01

    A review was made on the progress of lenticular opacities in proximally exposed A-bomb survivors on the basis of three experimental cases. A-bomb cataract is the first late effect of A-bomb radiation which appeared in A-bomb survivors and is the only disorder which can still be visualized at the present time. We have therefore continued to use this as one major evidence that A-bomb injuries have not been cured in spite of our for a complete ban of nuclear weapons. According to the findings of lenticular opacities of typical A-bomb cataract observed in experimental cases, there was in some cases after a latent period progression of opacities from several years to more than 10 years followed by a gradual decrease in opacities, whereas in some cases there was after a latent period a remarkable progress in opacities for several years followed by a marked decrease in the lesions. At the present time there is no evidence of progression and it appears that the progression has ceased. Incipient senile cataract which developed concurrently has completely no transitional relationship to A-bomb cataract and appears to progress slowly but steadily. (auth.)

  15. Prognostic impact of nomogram based on whole tumour size, tumour disappearance ratio on CT and SUVmax on PET in lung adenocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Song, So Hee; Lee, Ho Yun; Kim, Eun Young; Lee, Kyung Soo [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Gangnam-Gu, Seoul (Korea, Republic of); Ahn, Joong Hyun [Samsung Biomedical Research Institute, Biostatistics Team, Seoul (Korea, Republic of); Lee, Geewon [Pusan National University Hospital, Pusan National University School of Medicine, Department of Radiology and Medical Research Institute, Busan (Korea, Republic of); Choi, Joon Young [Sungkyunkwan University School of Medicine, Departments of Nuclear Medicine, Samsung Medical Center, Seoul (Korea, Republic of); Kang, Jun [Catholic University of Korea, Department of Pathology, Inchun St. Mary' s Hospital, College of Medicine, Inchun (Korea, Republic of); Han, Joungho [Sungkyunkwan University School of Medicine, Department of Pathology, Samsung Medical Center, Seoul (Korea, Republic of); Kwon, O.J. [Sungkyunkwan University School of Medicine, Division of Respiratory and Critical Medicine of the Department of Internal Medicine, Samsung Medical Center, Seoul (Korea, Republic of); Kim, Hong Kwan; Choi, Yong Soo; Kim, Jhingook; Shim, Young Mog [Sungkyunkwan University School of Medicine, Department of Thoracic and Cardiovascular Surgery, Samsung Medical Center, Seoul (Korea, Republic of)

    2016-06-15

    Lung adenocarcinoma frequently manifests as subsolid nodules, and the solid portion and ground-glass-opacity (GGO) portion on CT have different prognostic significance. Therefore, current T descriptor, defined as the whole tumour diameter without discrimination between solid and GGO, is insufficient. We aimed to determine the prognostic significance of solid tumour size and attempt to include prognostic factors such as tumour disappearance rate (TDR) on CT and SUVmax on PET/CT. Five hundred and ninety-five patients with completely resected lung adenocarcinoma were analyzed. We developed a nomogram using whole tumour size, TDR, and SUVmax. External validation was performed in another 102 patients. In patients with tumours measuring ≤2 cm and >2 to 3 cm, disease free survival (DFS) was significantly associated with solid tumour size (P < 0.001), but not with whole tumour size (P = 0.052). Developed nomogram was significantly superior to the conventional T stage (area under the curve of survival ROC; P = 0.013 by net reclassification improvement) in stratification of patient survival. In the external validation group, significant difference was noted in DFS according to proposed T stage (P = 0.009). Nomogram-based T descriptors provide better prediction of survival and assessment of individual risks than conventional T descriptors. (orig.)

  16. Lung cancer screening with low-dose helical CT in Korea: experiences at the Samsung Medical Center.

    Science.gov (United States)

    Chong, Semin; Lee, Kyung Soo; Chung, Myung Jin; Kim, Tae Sung; Kim, Hojoong; Kwon, O Jung; Choi, Yoon-Ho; Rhee, Chong H

    2005-06-01

    To determine overall detection rates of lung cancer by low-dose CT (LDCT) screening and to compare histopathologic and imaging differences of detected cancers between high- and low-risk groups, this study included 6,406 asymptomatic Korean adults with >or=45 yr of age who underwent LDCT for lung cancer screening. All were classified into high- (>or=20 pack-year smoking; 3,353) and low-risk (3,053; <20 pack-yr smoking and non-smokers) groups. We compared CT findings of detected cancers and detection rates between high- and low-risk. At initial CT, 35% (2,255 of 6,406) had at least one or more non-calcified nodule. Lung cancer detection rates were 0.36% (23 of 6,406). Twenty-one non-small cell lung cancers appeared as solid (n=14) or ground-glass opacity (GGO) (n=7) nodules. Cancer likelihood was higher in GGO nodules than in solid nodules (p<0.01). Fifteen of 23 cancers occurred in high-risk group and 8 in low-risk group (p=0.215). Therefore, LDCT screening help detect early stage of lung cancer in asymptomatic Korean population with detection rate of 0.36% on a population basis and may be useful for discovering early lung cancer in low-risk group as well as in high-risk group.

  17. Chest HRCT findings in acute transformation of adult T-cell lymphoma/leukemia

    International Nuclear Information System (INIS)

    Okada, Fumito; Sato, Haruka; Omeri, Ahmad Khalid; Ono, Asami; Tokuyama, Kouhei; Ando, Yumiko; Matsumoto, Akira; Mori, Hiromu; Ogata, Masao; Kohno, Kazuhiro; Takano, Kuniko

    2015-01-01

    To assess chest high-resolution computed tomography (HRCT) findings in patients with acute transformation of adult T cell leukaemia/lymphoma (ATLL). We retrospectively identified 72 consecutive patients at our institution with ATLL between October 2000 and March 2014. The cases included acute type (n = 20), lymphoma type (n = 21), smouldering type (n = 24) and chronic type (n = 7). Sixteen (7 men, 9 women; aged 36-85 years, mean 63.3 years) of 31 patients (24 with smouldering and seven with chronic type; 51.6 %) developed acute transformation of ATLL, and had undergone chest HRCT examinations. Parenchymal abnormalities, enlarged lymph nodes, pericardial effusion, pleural effusion and skin lesions were evaluated on HRCT. Chest HRCT of 15 of the 16 patients showed abnormal findings, including ground-glass opacity (GGO) (n = 8), consolidation (n = 5), interlobular septal thickening (n = 5) and nodules (n = 5). Pleural effusion was found in five patients, lymph node enlargement in 10 patients and multiple skin thickening in two patients. Almost all patients with acute transformation of ATLL had abnormal findings on chest HRCT, which consisted mainly of lymph node enlargement, GGO, interlobular septal thickening, nodules and bilateral pleural effusions. (orig.)

  18. An analysis of peripheral small lung carcinomas less than 20 mm in diameter in non-adenocarcinomas and carcinoids. Computed tomographic findings based on radiologic-pathologic correlation

    International Nuclear Information System (INIS)

    Tanaka, Gaku; Yamada, Kouzo; Oshita, Fumihiro; Nomura, Ikuo; Noda, Kazumasa; Nakayama, Haruhiko; Mitsuda, Aki; Kameda, Youichi; Yamakido, Michio

    2000-01-01

    With the introduction of computed tomography (CT) for chest screening in recent years, more cases of resected peripheral small lung carcinomas have been reported. Many of these were adenocarcinomas. To focus on CT findings of peripheral non-adenocarcinoma nodules, we performed a retrospective analysis based on radiographic-pathologic correlations. We analyzed CT findings based on the pathology of peripheral small lung carcinomas, excluding the histological type of adenocarcinomas. We compared our findings with those observed in adenocarcinomas. We reviewed 28 peripheral small lung carcinoma nodules less than 20 mm in diameter, including 13 squamous cell carcinomas, 4 small cell carcinomas, 2 adeno- squamous cell carcinomas, 1 large cell carcinoma, and 8 carcinoids. The carcinomas were classified into two different patterns; non-adenocarcinomas excluding carcinoids, and carcinoids. Both were solid-density types on high-resolution CT (HR-CT) images. The HR-CT findings regarding the shape and number of notching, and the presence or absence of ground glass opacity (GGO) were different between non-adenocarcinomas excluding carcinoids and adenocarcinomas. On the other hand, the HR-CT findings regarding spiculations, GGO and pleural indentations, and the absence of bronchial compression were different between carcinoids and adenocarcinomas. The shape characteristics and internal and marginal analysis on HR-CT images can contribute to the differential diagnosis of the histological type of peripheral small lung carcinomas. (author)

  19. Comparative analysis of clinicoradiologic characteristics of lung adenocarcinomas with ALK rearrangements or EGFR mutations

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, J.Y.; Zheng, J.; Chen, X.; Zhou, J.Y. [Zhejiang University, Department of Respiratory Disease, Thoracic Disease Center, First Affiliated Hospital, College of Medicine, Hangzhou (China); Yu, Z.F.; Xiao, W.B.; Jiang, L.N. [Zhejiang University, Department of Radiology, First Affiliated Hospital, College of Medicine, Hangzhou (China); Zhao, J.; Sun, K.; Wang, B.; Ding, W. [Zhejiang University, Department of Pathology, First Affiliated Hospital, College of Medicine, Hangzhou (China)

    2015-05-01

    To compare the clinicoradiologic features of tumours with echinoderm anaplastic lymphoma kinase (ALK) rearrangements, epidermal growth factor receptor (EGFR) mutations, or wild type (WT) for both genes in a cohort of patients with lung adenocarcinoma to identify useful characteristics of different gene statuses. In 346 lung adenocarcinoma patients, ALK rearrangements were confirmed with fluorescence in situ hybridisation, and EGFR mutations were determined by pyrosequencing assay. Patients were divided into three groups: ALK rearrangement (ALK+ group, n = 48), EGFR mutation (EGFR+ group, n = 166), and WT for both genes (WT group, n = 132). Chest computed tomography (CT) examinations were performed in all patients. The percentages of ground-glass opacity volume (pGGO) and tumour shadow disappearance rate (TDR) were measured using semi-automated nodule assessment software. The pGGO was significantly lower in the ALK+ group (25.1 % ± 24.3) than in the EGFR+ group (37.2 % ± 25.7, p < 0.001) and the WT group (36.1 % ± 24.6, p = 0.001). The TDR in the ALK+ group (17.3 % ± 25.1) was significantly lower than in the EGFR+ group (26.8 % ± 24.9, p = 0.002) and the WT group (25.7 % ± 24.6, p = 0.003). Solid pattern with lower incidence of lobulated border, finely spiculated margins, pleural retraction, and bubble-like lucency on CT imaging are the main characteristics of ALK rearrangement tumours. (orig.)

  20. Chest HRCT findings in acute transformation of adult T-cell lymphoma/leukemia

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Fumito; Sato, Haruka; Omeri, Ahmad Khalid; Ono, Asami; Tokuyama, Kouhei; Ando, Yumiko; Matsumoto, Akira; Mori, Hiromu [Oita University Faculty of Medicine, Department of Radiology, Yufu, Oita (Japan); Ogata, Masao; Kohno, Kazuhiro; Takano, Kuniko [Oita University Faculty of Medicine, Department of Medical Oncology and Hematology, Yufu, Oita (Japan)

    2015-06-01

    To assess chest high-resolution computed tomography (HRCT) findings in patients with acute transformation of adult T cell leukaemia/lymphoma (ATLL). We retrospectively identified 72 consecutive patients at our institution with ATLL between October 2000 and March 2014. The cases included acute type (n = 20), lymphoma type (n = 21), smouldering type (n = 24) and chronic type (n = 7). Sixteen (7 men, 9 women; aged 36-85 years, mean 63.3 years) of 31 patients (24 with smouldering and seven with chronic type; 51.6 %) developed acute transformation of ATLL, and had undergone chest HRCT examinations. Parenchymal abnormalities, enlarged lymph nodes, pericardial effusion, pleural effusion and skin lesions were evaluated on HRCT. Chest HRCT of 15 of the 16 patients showed abnormal findings, including ground-glass opacity (GGO) (n = 8), consolidation (n = 5), interlobular septal thickening (n = 5) and nodules (n = 5). Pleural effusion was found in five patients, lymph node enlargement in 10 patients and multiple skin thickening in two patients. Almost all patients with acute transformation of ATLL had abnormal findings on chest HRCT, which consisted mainly of lymph node enlargement, GGO, interlobular septal thickening, nodules and bilateral pleural effusions. (orig.)

  1. The solar elemental abundances problem: Large enhancements in photoionization and bound-free opacity

    Science.gov (United States)

    Pradhan, A.; Nahar, S.

    2016-05-01

    Aimed at solving the outstanding problem of solar opacity and radiation transport, we report substantial photoabsorption in the high-energy regime due to atomic core photo-excitations not heretofore considered. In an extensive R-Matrix calculations of unprecedented complexity for an important iron ion Fe XVII, with a wave function expansion of 99 Fe XVIII core states from n current opacity models, and ii) demonstrate convergence with respect to successive core excitations. These findings may explain the ``higher-than-predicted'' monochromatic iron opacity measured recently at the Sandia Z-pinch fusion device at solar interior conditions. The findings will also impact the total atomic photoabsorption and radiation transport in laboratory and astrophysical plasmas, such as UV emission from host stars of extra-solar planets. Support: NSF, DOE, Ohio Supercomputer Center, Columbus, OH.

  2. Constraints on cosmic opacity and beyond the standard model physics from cosmological distance measurements

    Energy Technology Data Exchange (ETDEWEB)

    Avgoustidis, Anastasios [Centre for Theoretical Cosmology, DAMTP, CMS, Wilberforce Road, Cambridge CB3 0WA (United Kingdom); Burrage, Clare [Deutsches Elektronen Synchrotron DESY, Notkestrasse 85, D-22607 Hamburg (Germany); Redondo, Javier [Max Planck Institut für Physik, Föhringer Ring 6, D-80805, Munich (Germany); Verde, Licia; Jimenez, Raul, E-mail: a.avgoustidis@damtp.cam.ac.uk, E-mail: clare.burrage@desy.de, E-mail: redondo@mppmu.mpg.de, E-mail: liciaverde@icc.ub.edu, E-mail: raul.jimenez@icc.ub.edu [ICREA and Institute for Sciences of the Cosmos (ICC), University of Barcelona, IEEC, Barcelona 08028 (Spain)

    2010-10-01

    We update constraints on cosmic opacity by combining recent SN Type Ia data with the latest measurements of the Hubble expansion at redshifts between 0 and 2. The new constraint on the parameter ε parametrising deviations from the luminosity-angular diameter distance relation (d{sub L} = d{sub A}(1+z){sup 2+ε}), is ε = −0.04{sub −0.07}{sup +0.08} (2-σ). For the redshift range between 0.2 and 0.35 this corresponds to an opacity Δτ < 0.012 (95% C.L.), a factor of 2 stronger than the previous constraint. Various models of beyond the standard model physics that predict violation of photon number conservation contribute to the opacity and can be equally constrained. In this paper we put new limits on axion-like particles, including chameleons, and mini-charged particles.

  3. Constraints on cosmic opacity and beyond the standard model physics from cosmological distance measurements

    Energy Technology Data Exchange (ETDEWEB)

    Avgoustidis, Anastasios [DAMTP, CMS, Cambridge (United Kingdom). Centre for Theoretical Cosmology; Burrage, Clare [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Redondo, Javier [Max-Planck-Institut fuer Physik, Munich (Germany); Verde, Licia; Jimenez, Raul [Barcelona Univ., IEEC (ES). ICREA and Inst. for Sciences of the Cosmos (ICC)

    2010-04-15

    We update constraints on cosmic opacity by combining recent SN Type Ia data compilation with the latest measurements of the Hubble expansion at redshifts between 0 and 2. The new constraint on the parameter {epsilon} parametrising deviations from the luminosity-angular diameter distance relation (d{sub L}=d{sub A}(1+z){sup 2+{epsilon}}), is {epsilon}=-0.04{sub -0.07}{sup +0.08} (2-{sigma}). For the redshift range between 0.2 and 0.35 this corresponds to an opacity {delta}{tau}<0.012 (95% C.L.), a factor of 2 stronger than the previous constraint. Various models of beyond the standard model physics that predict violation of photon number conservation contribute to the opacity and can be equally constrained. In this paper we put new limits on axion-like particles, including chameleons, and minicharged particles. (orig.)

  4. Constraints on cosmic opacity and beyond the standard model physics from cosmological distance measurements

    International Nuclear Information System (INIS)

    Avgoustidis, Anastasios; Redondo, Javier; Verde, Licia; Jimenez, Raul

    2010-04-01

    We update constraints on cosmic opacity by combining recent SN Type Ia data compilation with the latest measurements of the Hubble expansion at redshifts between 0 and 2. The new constraint on the parameter ε parametrising deviations from the luminosity-angular diameter distance relation (d L =d A (1+z) 2+ε ), is ε=-0.04 -0.07 +0.08 (2-σ). For the redshift range between 0.2 and 0.35 this corresponds to an opacity Δτ<0.012 (95% C.L.), a factor of 2 stronger than the previous constraint. Various models of beyond the standard model physics that predict violation of photon number conservation contribute to the opacity and can be equally constrained. In this paper we put new limits on axion-like particles, including chameleons, and minicharged particles. (orig.)

  5. OPAC Design Enhancements and Their Effects on Circulation and Resource Sharing within the Library Consortium Environment

    Directory of Open Access Journals (Sweden)

    Michael J. Bennett

    2007-03-01

    Full Text Available A longitudinal study of three discrete online public access catalog (OPAC design enhancements examined the possible effects such changes may have on circulation and resource sharing within the automated library consortium environment. Statistical comparisons were made of both circulation and interlibrary loan (ILL figures from the year before enhancement to the year after implementation. Data from sixteen libraries covering a seven-year period were studied in order to determine the degree to which patrons may or may not utilize increasingly broader OPAC ILL options over time. Results indicated that while ILL totals increased significantly after each OPAC enhancement, such gains did not result in significant corresponding changes in total circulation.

  6. Opacity measurements of tamped NaBr samples heated by z-pinch X-rays

    International Nuclear Information System (INIS)

    Bailey, J.E.; Arnault, P.; Blenski, T.; Dejonghe, G.; Peyrusse, O.; MacFarlane, J.J.; Mancini, R.C.; Cuneo, M.E.; Nielsen, D.S.; Rochau, G.A.

    2003-01-01

    Laboratory measurements provide benchmark data for wavelength-dependent plasma opacities to assist inertial confinement fusion, astrophysics, and atomic physics research. There are several potential benefits to using z-pinch radiation for opacity measurements, including relatively large cm-scale lateral sample sizes and relatively-long 3-5 ns experiment durations. These features enhance sample uniformity. The spectrally resolved transmission through a CH-tamped NaBr foil was measured. The z-pinch produced the X-rays for both the heating source and backlight source. The (50±4) eV foil electron temperature and (3±1)x10 21 cm -3 foil electron density were determined by analysis of the Na absorption features. LTE and NLTE opacity model calculations of the n=2 to 3, 4 transitions in bromine ionized into the M-shell are in reasonably good agreement with the data

  7. Smoke opacity in agricultural tractor in function of interior and metropolitano diesel mixture in mamona biodiesel

    Energy Technology Data Exchange (ETDEWEB)

    Tabile, Rubens Andre [Universidade de Sao Paulo (EESC/USP), Sao Carlos, SP (Brazil). Escola de Engenharia; Lopes, Afonso; Camara, Felipe Thomas da; Grotta, Danilo Cesar Checchio; Furlani, Carlos Eduardo Angeli [Universidade Estadual Paulista (DER/UNESP), Jaboticabal, SP (Brazil). Dept. de Engenharia Rural

    2008-07-01

    The great demand for energy sources by production systems allied to scarcity of fossil fuels has motivated the development and production of biodiesel, which is a fuel produced from renewable sources. Given that, the aim of this study was to compare smoke opacity of an agricultural tractor engine, working with metropolitano and interior diesel mixed to mamona biodiesel, in seven proportions. The tests were conducted in the Departamento de Engenharia Rural of UNESP/Jaboticabal - SP. The results showed that the diesel type did influence opacity of smoke, and metropolitano diesel showed best quality. It was also observed that, as biodiesel proportion increased, smoke opacity decreased until B75, turning to increase to B100. (author)

  8. Opacity and atomic analysis of double pulse laser ablated Li plasma

    Science.gov (United States)

    Sivakumaran, V.; Joshi, H. C.; Kumar, Ajai

    2014-09-01

    Opacity effects for neutral and ionic emission lines of lithium have been investigated by Atomic Data Analysis Structure (ADAS). Line ratios and opacity corrected photon emissivity coefficients are calculated over a wide range of electron temperatures and densities. The experimentally measured temporal evolution of the line profiles of the over dense Li plasma formed in the double pulse laser ablation experiment have been explained using the ADAS analysis and the plasma parameters of the plasma plume under consideration have been estimated. These results could be projected as a diagnostic tool to estimate plasma parameters of an over dense lithium plasma.

  9. Humane metapneumovirus (HMPV) associated pulmonary infections in immunocompromised adults—Initial CT findings, disease course and comparison to respiratory-syncytial-virus (RSV) induced pulmonary infections

    International Nuclear Information System (INIS)

    Syha, R.; Beck, R.; Hetzel, J.; Ketelsen, D.; Grosse, U.; Springer, F.; Horger, M.

    2012-01-01

    Aim: To describe computed tomography (CT)-imaging findings in human metapneumovirus (HMPV)-related pulmonary infection as well as their temporal course and to analyze resemblances/differences to pulmonary infection induced by the closely related respiratory-syncytial-virus (RSV) in immunocompromised patients. Materials and methods: Chest-CT-scans of 10 HMPV PCR-positive patients experiencing pulmonary symptoms were evaluated retrospectively with respect to imaging findings and their distribution and results were then compared with data acquired in 13 patients with RSV pulmonary infection. Subsequently, we analyzed the course of chest-findings in HMPV patients. Results: In HMPV, 8/10 patients showed asymmetric pulmonary findings, whereas 13/13 patients with RSV-pneumonia presented more symmetrical bilateral pulmonary infiltrates. Image analysis yielded in HMPV patients following results: ground-glass-opacity (GGO) (n = 6), parenchymal airspace consolidations (n = 5), ill-defined nodular-like centrilobular opacities (n = 9), bronchial wall thickening (n = 8). In comparison, results in RSV patients were: GGO (n = 10), parenchymal airspace consolidations (n = 9), ill-defined nodular-like centrilobular opacities (n = 10), bronchial wall thickening (n = 4). In the course of the disease, signs of acute HMPV interstitial pneumonia regressed transforming temporarily in part into findings compatible with bronchitis/bronchiolitis. Conclusions: Early chest-CT findings in patients with HMPV-related pulmonary symptoms are compatible with asymmetric acute interstitial pneumonia accompanied by signs of bronchitis; the former transforming with time into bronchitis and bronchiolitis before they resolve. On the contrary, RSV-induced pulmonary infection exhibits mainly symmetric acute interstitial pneumonia.

  10. Humane metapneumovirus (HMPV) associated pulmonary infections in immunocompromised adults—Initial CT findings, disease course and comparison to respiratory-syncytial-virus (RSV) induced pulmonary infections

    Energy Technology Data Exchange (ETDEWEB)

    Syha, R., E-mail: roland.syha@med.uni-tuebingen.de [Department of Diagnostic Radiology, Eberhard-Karls-University, Hoppe-Seyler-Str.3, 72076 Tübingen (Germany); Beck, R. [Institute of Medical Virology, Eberhard-Karls-University, Elfriede-Authorn-Str. 6, 72076 Tübingen (Germany); Hetzel, J. [Department of Medical Oncology and Hematology, Eberhard-Karls-University, Otfried-Müller-Str. 10, 72070 Tübingen (Germany); Ketelsen, D.; Grosse, U.; Springer, F.; Horger, M. [Department of Diagnostic Radiology, Eberhard-Karls-University, Hoppe-Seyler-Str.3, 72076 Tübingen (Germany)

    2012-12-15

    Aim: To describe computed tomography (CT)-imaging findings in human metapneumovirus (HMPV)-related pulmonary infection as well as their temporal course and to analyze resemblances/differences to pulmonary infection induced by the closely related respiratory-syncytial-virus (RSV) in immunocompromised patients. Materials and methods: Chest-CT-scans of 10 HMPV PCR-positive patients experiencing pulmonary symptoms were evaluated retrospectively with respect to imaging findings and their distribution and results were then compared with data acquired in 13 patients with RSV pulmonary infection. Subsequently, we analyzed the course of chest-findings in HMPV patients. Results: In HMPV, 8/10 patients showed asymmetric pulmonary findings, whereas 13/13 patients with RSV-pneumonia presented more symmetrical bilateral pulmonary infiltrates. Image analysis yielded in HMPV patients following results: ground-glass-opacity (GGO) (n = 6), parenchymal airspace consolidations (n = 5), ill-defined nodular-like centrilobular opacities (n = 9), bronchial wall thickening (n = 8). In comparison, results in RSV patients were: GGO (n = 10), parenchymal airspace consolidations (n = 9), ill-defined nodular-like centrilobular opacities (n = 10), bronchial wall thickening (n = 4). In the course of the disease, signs of acute HMPV interstitial pneumonia regressed transforming temporarily in part into findings compatible with bronchitis/bronchiolitis. Conclusions: Early chest-CT findings in patients with HMPV-related pulmonary symptoms are compatible with asymmetric acute interstitial pneumonia accompanied by signs of bronchitis; the former transforming with time into bronchitis and bronchiolitis before they resolve. On the contrary, RSV-induced pulmonary infection exhibits mainly symmetric acute interstitial pneumonia.

  11. Open-Source Tools for Enhancing Full-Text Searching of OPACs: Use of Koha, Greenstone and Fedora

    Science.gov (United States)

    Anuradha, K. T.; Sivakaminathan, R.; Kumar, P. Arun

    2011-01-01

    Purpose: There are many library automation packages available as open-source software, comprising two modules: staff-client module and online public access catalogue (OPAC). Although the OPAC of these library automation packages provides advanced features of searching and retrieval of bibliographic records, none of them facilitate full-text…

  12. Color and opacity of composites protected with surface sealants and submitted to artificial accelerated aging.

    Science.gov (United States)

    Aguilar, Fabiano Gamero; Roberti Garcia, Lucas da Fonseca; Cruvinel, Diogo Rodrigues; Sousa, Ana Beatriz Silva; de Carvalho Panzeri Pires-de-Souza, Fernanda

    2012-01-01

    To evaluate the color similarity, stability and opacity of composites (TPH, Charisma, and Concept, shade A2) protected with surface sealants (Fortify Plus and Biscover) and cyanoacrylate (Super Bonder). Forty specimens of each composite were made and separated into 4 groups (n=10) according to the surface protection: GI - without sealant; GII - cyanoacrylate; GIII - Fortify Plus; GIV - Biscover. Color and opacity readings were taken before and after Artificial Acelerated Aging (AAA) and the values obtained for color stability were submitted to statistical analysis by 2-way ANOVA and Bonferroni's test (P<.05). The values acquired for color similarity were submitted to 1-way ANOVA and Tukey's test (P<.05). The specimen sufaces were compared before and after AAA using Scanning Electronic Microscopy (SEM). Studied composites did not present the same values for the coordinates L*, a* and b * before AAA, indicating that there was no color similarity among them. All composites presented color alteration after AAA with clinically unacceptable values. Protected groups presented lower opacity variation after AAA, in comparison with the control goup. SEM evaluation demonstrated that AAA increased the surface irregularities in all of the studied groups. Surface sealants were not effective in maintaining composite color, but were able to maintain opacity.

  13. Opportunities for Laboratory Opacity Chemistry Studies to Facilitate Characterization of Young Giant Planets and Brown Dwarfs

    Science.gov (United States)

    Marley, Mark; Freedman, Richard S.

    2015-01-01

    The thermal emission spectra of young giant planets is shaped by the opacity of atoms and molecules residing in their atmospheres. While great strides have been made in improving the opacities of important molecules, particularly NH3 and CH4, at high temperatures, much more work is needed to understand the opacity and chemistry of atomic Na and K. The highly pressure broadened fundamental band of Na and K in the optical stretches into the near-infrared, strongly influencing the shape of the Y and K spectral bands. Since young giant planets are bright in these bands it is important to understand the influences on the spectral shape. Discerning gravity and atmospheric composition is difficult, if not impossible, without both good atomic opacities as well as an excellent understanding of the relevant atmospheric chemistry. Since Na and K condense at temperatures near 500 to 600 K, the chemistry of the condensation process must be well understood as well, particularly any disequilibrium chemical pathways. Comparisons of the current generation of sophisticated atmospheric models and available data, however, reveal important shortcomings in the models. We will review the current state of observations and theory of young giant planets and will discuss these and other specific examples where improved laboratory measurements for alkali compounds have the potential of substantially improving our understanding of these atmospheres.

  14. Important consequences of atomic diffusion inside main-sequence stars: opacities, extra-mixing, oscillations

    Directory of Open Access Journals (Sweden)

    Deal M.

    2017-01-01

    Full Text Available Atomic diffusion, including the effects of radiative accelerations on individual elements, leads to important variations of the chemical composition inside stars. The accumulation of important elements in specific layers leads to a local increase of the average opacity and to hydrodynamic instabilities that modify the internal stellar structure. This can also have important consequences for asteroseismology.

  15. Opacity of financial information, adoption of international standards and legal origins

    Directory of Open Access Journals (Sweden)

    Renata Turola Takamatsu

    2017-10-01

    Full Text Available Purpose – The goal of this study was to investigate the relationship between the level of Earnings Opacity and a company’s informational environment, specifically considering accounting standards and the legal origins of the system. Design/methodology/approach – The sample consisted of publicly traded companies from 20 countries classified as emerging, based on agency Standard & Poor’s index. The sample included data from 2004 to 2013. In order to compare the indicators among the group of countries, taking into account their institutional characteristics, the Mann-Whitney test and the Kruskal-Wallis test were performed. Findings – The assessment of the informational environment measures’ behavior in emerging countries revealed that these measures were correlated, suggesting that, despite different behaviors, opacity proxies share information. The fact that earnings opacity was lower in countries that had already adopted international standards during the analyzed period was also observed. In the same sense, a higher level of income smoothing was detected in countries of French code law origins. Originality/value – This article contributes to the understanding of the relationship between the characteristics of an accounting informational environment and the levels of opacity of the information emitted by accounting. Thus, this article has helped managers, investors and regulators to understand users’ needs and how country-specific characteristics change their perspectives.

  16. Biodegradable X-ray markers of controlled radio-opacity. Temporary position measurements in bone

    NARCIS (Netherlands)

    Stallmann, H.P.; Faber, C.; Plokker, H.M.; Wuisman, P.I.J.M.

    2005-01-01

    In order to analyze X-ray markers for potential use in biodegradable implants or radiostereogrammatic analysis (RSA), we combined iopromide contrast fluid with biodegradable calcium phosphate cement. The radio-opacity of 10 × 10 mm markers containing different iodine concentrations (0,120, 240, 360

  17. The relationship between elastomer opacity, colorimeter beam size, and measured colorimetric response.

    Science.gov (United States)

    Rugh, E H; Johnston, W M; Hesse, N S

    1991-01-01

    The effect of opacity on the colorimetric responses of large-area and small-area colorimeters was determined using an elastomer intended for maxillofacial prosthetics use and containing various pigments at different concentrations. Opacity was determined by calculating the contrast ratio of 2-mm-thick specimens against black and white backings, using Kubelka-Munk analyses to correct for thickness and backing color variations. The measure of comparison of the two colorimeters was the relative difference in tristimulus reflectance, with the tristimulus reflectance of the large-area colorimeter as the basis of the relative difference. A significant quadratic relationship was found between contrast ratio and the relative difference in tristimulus reflectance. This relationship may be used to describe opacity without the need to make optical observations or measurements of a thin layer of material on contrasting backings. The small-area colorimeter produced color parameters that are a measure of the combined effects of both color and opacity. The importance of beam size considerations of optical measuring devices for translucent natural and prosthetic materials was emphasized.

  18. 77 FR 8160 - Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary Sources

    Science.gov (United States)

    2012-02-14

    ... with the opacity measurement/reference beam(s), spectrally selective optical filters, beam splitters... Monitor Manufacturers to Certify Conformance with Design and Performance Specifications, whereas the 2003... my COMS? Necessary components of the routine system checks will depend on the design details of your...

  19. UTILITARIAN OPACITY MODEL FOR AGGREGATE PARTICLES IN PROTOPLANETARY NEBULAE AND EXOPLANET ATMOSPHERES

    International Nuclear Information System (INIS)

    Cuzzi, Jeffrey N.; Davis, Sanford S.; Estrada, Paul R.

    2014-01-01

    As small solid grains grow into larger ones in protoplanetary nebulae, or in the cloudy atmospheres of exoplanets, they generally form porous aggregates rather than solid spheres. A number of previous studies have used highly sophisticated schemes to calculate opacity models for irregular, porous particles with sizes much smaller than a wavelength. However, mere growth itself can affect the opacity of the medium in far more significant ways than the detailed compositional and/or structural differences between grain constituents once aggregate particle sizes exceed the relevant wavelengths. This physics is not new; our goal here is to provide a model that provides physical insight and is simple to use in the increasing number of protoplanetary nebula evolution and exoplanet atmosphere models appearing in recent years, yet quantitatively captures the main radiative properties of mixtures of particles of arbitrary size, porosity, and composition. The model is a simple combination of effective medium theory with small-particle closed-form expressions, combined with suitably chosen transitions to geometric optics behavior. Calculations of wavelength-dependent emission and Rosseland mean opacity are shown and compared with Mie theory. The model's fidelity is very good in all comparisons we have made except in cases involving pure metal particles or monochromatic opacities for solid particles with sizes comparable to the wavelength

  20. Impact of Internet Search Engines on OPAC Users: A Study of Punjabi University, Patiala (India)

    Science.gov (United States)

    Kumar, Shiv

    2012-01-01

    Purpose: The aim of this paper is to study the impact of internet search engine usage with special reference to OPAC searches in the Punjabi University Library, Patiala, Punjab (India). Design/methodology/approach: The primary data were collected from 352 users comprising faculty, research scholars and postgraduate students of the university. A…

  1. A clickstream data analysis of Chinese academic library OPAC users' information behavior

    NARCIS (Netherlands)

    Jiang, Tingting; Chi, Yu; Gao, Huiqin

    2017-01-01

    Chinese academic libraries have been devoting great effort into introducing next-generation online public access catalogs (OPACs) in order to provide a better user experience. However, there is a lack of empirical research on their usage. In this study, a transaction log file from a typical

  2. The Belfast atomic data bank, recommended data, and the opacity project data base

    International Nuclear Information System (INIS)

    Berrington, K.A.; Kingston, A.E.; Sawey, P.M.J.

    1991-01-01

    The Belfast Atomic Data Bank holds data for the excitation and ionisation of atoms and ions by electrons and photons, and provides recommended data; electron excitation data recommended at regular Atomic Data Workshops is summarised. Photoabsorption data for all elements up to Fe have been calculated in the international Opacity Project, and a summary is given of the atomic data expected from the Project

  3. Medical management of bilateral corneal opacity in an Asian elephant (Elephas maximus: A case report

    Directory of Open Access Journals (Sweden)

    Pranab Paul

    2018-03-01

    Full Text Available Objective: This study was aimed at studying efficacy of medical management of corneal opacity in an Asian elephant (Elephas maximus. Material and methods: A 42 years old male Asian elephant was brought to the Teaching Veterinary Hospital (TVH at Chittagong Veterinary and Animal Sciences University (CVASU with a history of chronic lacrimation and impaired vision. On clinical examination, the animal was found apparently healthy. Opthalmological examination tentatively revealed the condition as corneal opacity. The left eye was much more affected as compared to the right one. Medical management was instituted with topical administration of ciprofloxacin, dexamethasone, subconjunctival prednisolone and dexamethasone along with intramuscular ketoprofen (at 1 mg/Kg bwt and vitamin A (at 5000 IU/Kg bwt. Results: The “mahout” (elepenat caretaker of the elephant was kept in close contact over cell phone to follow up the progress of the condition. Clinical examination after 19 days revealed complete recovery of the cornel opacity. There was no sign of lacrimation and the animal regained its normal vision. Conclusion: The treatment protocol successfully eliminated the discomfort along with corneal opacity and lacrimation in an Asian elephant. [J Adv Vet Anim Res 2018; 5(1.000: 98-100

  4. Gray and multigroup radiation transport models for two-dimensional binary stochastic media using effective opacities

    International Nuclear Information System (INIS)

    Olson, Gordon L.

    2016-01-01

    One-dimensional models for the transport of radiation through binary stochastic media do not work in multi-dimensions. Authors have attempted to modify or extend the 1D models to work in multidimensions without success. Analytic one-dimensional models are successful in 1D only when assuming greatly simplified physics. State of the art theories for stochastic media radiation transport do not address multi-dimensions and temperature-dependent physics coefficients. Here, the concept of effective opacities and effective heat capacities is found to well represent the ensemble averaged transport solutions in cases with gray or multigroup temperature-dependent opacities and constant or temperature-dependent heat capacities. In every case analyzed here, effective physics coefficients fit the transport solutions over a useful range of parameter space. The transport equation is solved with the spherical harmonics method with angle orders of n=1 and 5. Although the details depend on what order of solution is used, the general results are similar, independent of angular order. - Highlights: • Gray and multigroup radiation transport is done through 2D stochastic media. • Approximate models for the mean radiation field are found for all test problems. • Effective opacities are adjusted to fit the means of stochastic media transport. • Test problems include temperature dependent opacities and heat capacities • Transport solutions are done with angle orders n=1 and 5.

  5. Lens opacities in children of Belarus affected by the Chernobyl accident

    Energy Technology Data Exchange (ETDEWEB)

    Arinchin, A.N.; Ospennikova, L.A. [Research Clinical Institute of Radiation Medicine and Endocrinology, Ministry of Health, Republic of Belarus, Aksakovschina, Minsk (Belarus)

    1998-03-01

    Reports about the increase in cataracts among the Ukrainian population living in the region of the Chernobyl Atomic Power Plant have been met with certain skepticism. At the same time, American specialists do not exclude the possibility of radiation genesis of lensopathias revealed among the citizens of Ukraine at the result of complex joint clinic-epidemiological study conducted by American and Ukrainian specialists in 1991. The aim of the investigation was to study the frequency and character of lens opacities in children permanently residing in the contaminated territories of the Republic of Belarus with anomalous high coefficients of {sup 137}Cs radionuclides through the food chain. It is well known that radiation cataract is one of the direct effects of ionizing radiation. Organ of sight is highly radiosensitive. The most radio-vulnerable part of eye is lens in which cataract is developing in response to both external and internal exposure. In children, focal lens opacities are localized in embryonic nucleus, but in elderly people, alongside with embryonic nucleus, they are also localized in adult nucleus and cortical layers. Lens opacity is the result of biochemical changes occurring in it, and it is caused by lens fibers damage. Frequency of occurrence of lensopathias in children from the main group made 82.1% which is by 12.5% more than in the control, mostly due to opacities in both lenses. (J.P.N.)

  6. Lens opacities in children of Belarus affected by the Chernobyl accident

    International Nuclear Information System (INIS)

    Arinchin, A.N.; Ospennikova, L.A.

    1998-01-01

    Reports about the increase in cataracts among the Ukrainian population living in the region of the Chernobyl Atomic Power Plant have been met with certain skepticism. At the same time, American specialists do not exclude the possibility of radiation genesis of lensopathias revealed among the citizens of Ukraine at the result of complex joint clinic-epidemiological study conducted by American and Ukrainian specialists in 1991. The aim of the investigation was to study the frequency and character of lens opacities in children permanently residing in the contaminated territories of the Republic of Belarus with anomalous high coefficients of 137 Cs radionuclides through the food chain. It is well known that radiation cataract is one of the direct effects of ionizing radiation. Organ of sight is highly radiosensitive. The most radio-vulnerable part of eye is lens in which cataract is developing in response to both external and internal exposure. In children, focal lens opacities are localized in embryonic nucleus, but in elderly people, alongside with embryonic nucleus, they are also localized in adult nucleus and cortical layers. Lens opacity is the result of biochemical changes occurring in it, and it is caused by lens fibers damage. Frequency of occurrence of lensopathias in children from the main group made 82.1% which is by 12.5% more than in the control, mostly due to opacities in both lenses. (J.P.N.)

  7. Penerapan Bahasa Alami Sederhana pada Online Public Access Catalog (Opac) Berbasis Web Semantik

    OpenAIRE

    Andri, Andri

    2012-01-01

    Online Public Access Catalog (OPAC) merupakan sistem katalog online yang memanfaatkan teknologi komputer dan internet sebagai media pengaksesan dan penyimpanan datanya. Sebuah katalog biasanya memberikan informasi mengenai koleksi yang disimpan dalam sebuah perpustakaan digital. Dalam penelitian ini akan dibuat sebuah prototipe aplikasi pencarian pada katalog online di perpustakaan Universitas Binadarma Palembang berbasis teknologi web semantik serta menerapkan pengolahan bahasa alami sederha...

  8. A Longitudinal Study of the Effects of OPAC Screen Changes on Searching Behavior and Searcher Success.

    Science.gov (United States)

    Blecic, Deborah D.; Dorsch, Josephine L.; Koenig, Melissa H.; Bangalore, Nimala S.

    1999-01-01

    Describes a longitudinal study of four sets of OPAC (online public access catalog) transaction logs that examined the effects of screen changes in helping searchers improve their search behavior. Results show that while screen changes initially had a positive impact on search behavior, they were not always sustained over time. (Author/LRW)

  9. We Never Have to Say Goodbye: Finding a Place for OPACS in Discovery Environments

    Science.gov (United States)

    Matthews, J. Greg

    2009-01-01

    It is easy to lament the shortcomings of traditional online public access catalogs (OPACs) in the Google Age. Users cannot, for example, usually input a snippet of a long-forgotten pop song's chorus into an online library catalog and almost instantly retrieve a relevant result along with hundreds of other options. On the other hand, should OPACs…

  10. Delivering Electronic Resources with Web OPACs and Other Web-based Tools: Needs of Reference Librarians.

    Science.gov (United States)

    Bordeianu, Sever; Carter, Christina E.; Dennis, Nancy K.

    2000-01-01

    Describes Web-based online public access catalogs (Web OPACs) and other Web-based tools as gateway methods for providing access to library collections. Addresses solutions for overcoming barriers to information, such as through the implementation of proxy servers and other authentication tools for remote users. (Contains 18 references.)…

  11. Calculation of radiative opacity of plasma mixtures using a relativistic screened hydrogenic model

    International Nuclear Information System (INIS)

    Mendoza, M.A.; Rubiano, J.G.; Gil, J.M.; Rodríguez, R.; Florido, R.; Espinosa, G.; Martel, P.; Mínguez, E.

    2014-01-01

    We present the code ATMED based on an average atom model and conceived for fast computing the population distribution and radiative properties of hot and dense single and multicomponent plasmas under LTE conditions. A relativistic screened hydrogenic model (RSHM), built on a new set of universal constants considering j-splitting, is used to calculate the required atomic data. The opacity model includes radiative bound–bound, bound–free, free–free, and scattering processes. Bound–bound line-shape function has contributions from natural, Doppler and electron-impact broadenings. An additional dielectronic broadening to account for fluctuations in the average level populations has been included, which improves substantially the Rosseland mean opacity results. To illustrate the main features of the code and its capabilities, calculations of several fundamental quantities of one-component plasmas and mixtures are presented, and a comparison with previously published data is performed. Results are satisfactorily compared with those predicted by more elaborate codes. - Highlights: • A new opacity code, ATMED, based on the average atom approximation is presented. • Atomic data are computed by means of a relativistic screened hydrogenic model. • An effective bound level degeneracy is included for accounting pressure ionization. • A new dielectronic line broadening is included to improve the mean opacities. • ATMED has the possibility to handle with single element and multicomponent plasmas

  12. Measuring the iron spectral opacity in solar conditions using a double ablation front scheme

    Energy Technology Data Exchange (ETDEWEB)

    Colaitis, A. [Centre Lasers Intenses et Applications, Talence (France); CEA/DRF/IRFU/DAp, CEA Saclay (France); Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Univ. of Rochester, NY (United States). Lab. for Laser Energetics; Ducret, J. E. [Centre Lasers Intenses et Applications, Talence (France); CEA/DRF/IRFU/DAp, CEA Saclay (France); Turck-Chieze, S [CEA/DRF/IRFU/DAp, CEA Saclay (France); Pennec, M L [CEA/DRF/IRFU/DAp, CEA Saclay (France); CEA/DIF, Arpajon (France); Blancard, C [CEA/DIF, Arpajon (France)

    2018-01-22

    We propose a new method to achieve hydrodynamic conditions relevant for the investigation of the radiation transport properties of the plasma at the base of the solar convection zone. The method is designed in the framework of opacity measurements with high-power lasers and exploits the temporal and spatial stability of hydrodynamic parameters in counter-propagating Double Ablation Front (DAF) structures.

  13. Fungus infection in immunocompromised rabbits: correlation of thin-section CT findings and histopathology

    International Nuclear Information System (INIS)

    Xue Feng; Liu Shiyuan; Xie Lixuan; Liu Kai; Zhang Jian; Chen Yousan; Li Huimin; He Jin

    2009-01-01

    Objective: To compare the thin-section CT findings of pulmonary candidiasis, aspergillosis and cryptococcosis with histopathology in immunocompromised rabbits and improve the diagnostic accuracy of fungus infection. Methods: Healthy New Zealand white rabbits were used for immunocompromised animal models. Thin-section CT scan was performed before and 2, 4, 6, 8, 10, 12, 14 d after inoculation. The pattern and distribution of the pulmonary abnormalities were retrospectively assessed by two thoracic radiologists and compared with histopathology. The granulocyte count was compared before and after administration of immunosuppressive agents. The paired t test, chi square test and the Fisher's exact test were used for the statistics. Results: Fourteen rabbits had candidiasis, 16 rabbits had eryptococcosis, 15 rabbits had aspergillosis. The granulocyte counts before and after administration of immunosuppressive agents were (2.91±0.92) and (0.35±0.19) x 10 9 /L respectively in candidiasis group, there was a significant difference (t=12.484, P 9 /L in aspergillosis group, there was a significant difference (t=5.792, P 9 /L in cryptococcosis group, there was a significant difference (t=8.199, P 0.05). Ground glass opacity (GGO) and consolidation were the two most common findings in immunocompromised rabbits with three fungus infections, areas of GGO was correlated with the congestion, hemorrhage, inflammatory cell infiltration and interstitial hyperplasia in pathology. Consolidation was correlated with the severe congestion, hemorrhage, inflammatory cell infiltration, interstitial hyperplasia, necrosis and vascular embolism in pathology. Conclusion: GGO and consolidation are the two most common findings of fungus infections in immunocompromised animal models and thin-section CT findings can reflect the pathological changes. (authors)

  14. Benefit of computer-aided detection analysis for the detection of subsolid and solid lung nodules on thin- and thick-section CT.

    Science.gov (United States)

    Godoy, Myrna C B; Kim, Tae Jung; White, Charles S; Bogoni, Luca; de Groot, Patricia; Florin, Charles; Obuchowski, Nancy; Babb, James S; Salganicoff, Marcos; Naidich, David P; Anand, Vikram; Park, Sangmin; Vlahos, Ioannis; Ko, Jane P

    2013-01-01

    The objective of our study was to evaluate the impact of computer-aided detection (CAD) on the identification of subsolid and solid lung nodules on thin- and thick-section CT. For 46 chest CT examinations with ground-glass opacity (GGO) nodules, CAD marks computed using thin data were evaluated in two phases. First, four chest radiologists reviewed thin sections (reader(thin)) for nodules and subsequently CAD marks (reader(thin) + CAD(thin)). After 4 months, the same cases were reviewed on thick sections (reader(thick)) and subsequently with CAD marks (reader(thick) + CAD(thick)). Sensitivities were evaluated. Additionally, reader(thick) sensitivity with assessment of CAD marks on thin sections was estimated (reader(thick) + CAD(thin)). For 155 nodules (mean, 5.5 mm; range, 4.0-27.5 mm)-74 solid nodules, 22 part-solid (part-solid nodules), and 59 GGO nodules-CAD stand-alone sensitivity was 80%, 95%, and 71%, respectively, with three false-positives on average (0-12) per CT study. Reader(thin) + CAD(thin) sensitivities were higher than reader(thin) for solid nodules (82% vs 57%, p thick), reader(thick) + CAD(thick), reader(thick) + CAD(thin) were 40%, 58% (p thick); false-positive rates were 1.17, 1.19, and 1.26 per case for reader(thick), reader(thick) + CAD(thick), and reader(thick) + CAD(thin), respectively. Detection of GGO nodules and solid nodules is significantly improved with CAD. When interpretation is performed on thick sections, the benefit is greater when CAD marks are reviewed on thin rather than thick sections.

  15. CT appearance of radiation injury of the lung and clinical symptoms after stereotactic body radiation therapy (SBRT) for lung cancers: Are patients with pulmonary emphysema also candidates for SBRT for lung cancers?

    International Nuclear Information System (INIS)

    Kimura, Tomoki; Matsuura, Kanji; Murakami, Yuji; Hashimoto, Yasutoshi; Kenjo, Masahiro; Kaneyasu, Yuko; Wadasaki, Koichi; Hirokawa, Yutaka; Ito, Katsuhide; Okawa, Motoomi

    2006-01-01

    Purpose: The purpose of this study was to analyze the computed tomographic (CT) appearance of radiation injury to the lung and clinical symptoms after stereotactic body radiation therapy (SBRT) and evaluate the difference by the presence of pulmonary emphysema (PE) for small lung cancers. Methods and Materials: In this analysis, 45 patients with 52 primary or metastatic lung cancers were enrolled. We evaluated the CT appearance of acute radiation pneumonitis (within 6 months) and radiation fibrosis (after 6 months) after SBRT. Clinical symptoms were evaluated by Common Terminology Criteria for Adverse Events, version 3.0. We also evaluated the relationship between CT appearance, clinical symptoms, and PE. Results: CT appearance of acute radiation pneumonitis was classified as follows: (1) diffuse consolidation, 38.5%; (2) patchy consolidation and ground-glass opacities (GGO), 15.4%; (3) diffuse GGO, 11.5%; (4) patchy GGO, 2.0%; (5) no evidence of increasing density, 32.6%. CT appearance of radiation fibrosis was classified as follows: (1) modified conventional pattern, 61.5%; (2) mass-like pattern, 17.3%; (3) scar-like pattern, 21.2%. Patients who were diagnosed with more than Grade 2 pneumonitis showed significantly less no evidence of increased density pattern and scar-like pattern than any other pattern (p = 0.0314, 0.0297, respectively). Significantly, most of these patients with no evidence of increased density pattern and scar-like pattern had PE (p = 0.00038, 0.00044, respectively). Conclusion: Computed tomographic appearance after SBRT was classified into five patterns of acute radiation pneumonitis and three patterns of radiation fibrosis. Our results suggest that SBRT can be also safely performed even in patients with PE

  16. Pulmonary nodules: effect of adaptive statistical iterative reconstruction (ASIR) technique on performance of a computer-aided detection (CAD) system-comparison of performance between different-dose CT scans.

    Science.gov (United States)

    Yanagawa, Masahiro; Honda, Osamu; Kikuyama, Ayano; Gyobu, Tomoko; Sumikawa, Hiromitsu; Koyama, Mitsuhiro; Tomiyama, Noriyuki

    2012-10-01

    To evaluate the effects of ASIR on CAD system of pulmonary nodules using clinical routine-dose CT and lower-dose CT. Thirty-five patients (body mass index, 22.17 ± 4.37 kg/m(2)) were scanned by multidetector-row CT with tube currents (clinical routine-dose CT, automatically adjusted mA; lower-dose CT, 10 mA) and X-ray voltage (120 kVp). Each 0.625-mm-thick image was reconstructed at 0%-, 50%-, and 100%-ASIR: 0%-ASIR is reconstructed using only the filtered back-projection algorithm (FBP), while 100%-ASIR is reconstructed using the maximum ASIR and 50%-ASIR implies a blending of 50% FBP and ASIR. CAD output was compared retrospectively with the results of the reference standard which was established using a consensus panel of three radiologists. Data were analyzed using Bonferroni/Dunn's method. Radiation dose was calculated by multiplying dose-length product by conversion coefficient of 0.021. The consensus panel found 265 non-calcified nodules ≤ 30 mm (ground-glass opacity [GGO], 103; part-solid, 34; and solid, 128). CAD sensitivity was significantly higher at 100%-ASIR [clinical routine-dose CT, 71% (overall), 49% (GGO); lower-dose CT, 52% (overall), 67% (solid)] than at 0%-ASIR [clinical routine-dose CT, 54% (overall), 25% (GGO); lower-dose CT, 36% (overall), 50% (solid)] (pASIR (clinical routine-dose CT, 8.5; lower-dose CT, 6.2) than at 0%-ASIR (clinical routine-dose CT, 4.6; lower-dose CT, 3.5; pASIR on lower-dose CT is almost equal to that at 0%-ASIR on clinical routine-dose CT. ASIR can increase CAD sensitivity despite increased false-positive findings. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  17. High-resolution computed tomography findings of swine-origin influenza A (H1N1) virus (S-OIV) infection: comparison with scrub typhus

    International Nuclear Information System (INIS)

    Jo, Bang Sil; Lee, In Jae; Lee, Kwanseop; Im, Hyoung June

    2012-01-01

    Background. Swine-origin influenza A (H1N1) virus (S-OIV) infection and scrub typhus, also known as tsutsugamushi disease can manifest as acute respiratory illnesses, particularly during the late fall or early winter, with similar radiographic findings, such as a predominance of ground-glass opacity (GGO). Purpose. To differentiate S-OIV infection from scrub typhus using high-resolution computed tomography (HRCT). Material and Methods. We retrospectively reviewed the HRCT findings of 14 patients with S-OIV infection and 10 patients with scrub typhus. We assessed the location, cross-sectional distribution, and the presence of a peribronchovascular distribution of GGO and consolidations on HRCT. We also assessed the presence of interlobular septal thickening, bronchial wall thickening, pneumothorax, pneumomediastinum, pleural effusion, and mediastinal or axillary lymph node enlargement. Results. Scrub typhus was more common than S-OIV in elderly patients (P < 0.001). The monthly incidences of S-OIV and scrub typhus infection reached a peak between October and November. About 86% of S-OIV patients and 80% of scrub typhus patients presented with GGO. About 67% of the GGO lesions in S-OIV had a peribronchovascular distribution, but this was absent in scrub typhus (P = 0.005). Consolidation (93% vs. 10%, P < 0.001) and bronchial wall thickening (43% vs. 0%, P = 0.024) were more frequent in S-OIV infection than scrub typhus. Interlobular septal thickening (90% vs. 36%, P = 0.013) and axillary lymphadenopathy (90% vs. 0%, P < 0.001) were more common in scrub typhus than S-OIV infection. Conclusion. There was considerable overlap in HRCT findings between S-OIV infection and scrub typhus. However, S-OIV showed a distinctive peribronchovascular distribution of GGO lesions. Consolidation and bronchial wall thickening were seen more frequently in S-OIV infection, whereas interlobular septal thickening and axillary lymphadenopathy were more common in scrub typhus. Thus, CT could

  18. High-resolution computed tomography findings of swine-origin influenza A (H1N1) virus (S-OIV) infection: comparison with scrub typhus

    Energy Technology Data Exchange (ETDEWEB)

    Jo, Bang Sil; Lee, In Jae; Lee, Kwanseop [Dept. of Radiology, Hallym Univ. College of Medicine, Seoul (Korea, Republic of)], E-mail: ijlee2003@medimail.co.kr; Im, Hyoung June [Dept. of Occupational Medicine, Hallym Univ. College of Medicine, Seoul (Korea, Republic of)

    2012-07-15

    Background. Swine-origin influenza A (H1N1) virus (S-OIV) infection and scrub typhus, also known as tsutsugamushi disease can manifest as acute respiratory illnesses, particularly during the late fall or early winter, with similar radiographic findings, such as a predominance of ground-glass opacity (GGO). Purpose. To differentiate S-OIV infection from scrub typhus using high-resolution computed tomography (HRCT). Material and Methods. We retrospectively reviewed the HRCT findings of 14 patients with S-OIV infection and 10 patients with scrub typhus. We assessed the location, cross-sectional distribution, and the presence of a peribronchovascular distribution of GGO and consolidations on HRCT. We also assessed the presence of interlobular septal thickening, bronchial wall thickening, pneumothorax, pneumomediastinum, pleural effusion, and mediastinal or axillary lymph node enlargement. Results. Scrub typhus was more common than S-OIV in elderly patients (P < 0.001). The monthly incidences of S-OIV and scrub typhus infection reached a peak between October and November. About 86% of S-OIV patients and 80% of scrub typhus patients presented with GGO. About 67% of the GGO lesions in S-OIV had a peribronchovascular distribution, but this was absent in scrub typhus (P = 0.005). Consolidation (93% vs. 10%, P < 0.001) and bronchial wall thickening (43% vs. 0%, P = 0.024) were more frequent in S-OIV infection than scrub typhus. Interlobular septal thickening (90% vs. 36%, P = 0.013) and axillary lymphadenopathy (90% vs. 0%, P < 0.001) were more common in scrub typhus than S-OIV infection. Conclusion. There was considerable overlap in HRCT findings between S-OIV infection and scrub typhus. However, S-OIV showed a distinctive peribronchovascular distribution of GGO lesions. Consolidation and bronchial wall thickening were seen more frequently in S-OIV infection, whereas interlobular septal thickening and axillary lymphadenopathy were more common in scrub typhus. Thus, CT could

  19. Autofluorescence imaging of macular pigment: influence and correction of ocular media opacities

    Science.gov (United States)

    Sharifzadeh, Mohsen; Obana, Akira; Gohto, Yuko; Seto, Takahiko; Gellermann, Werner

    2014-09-01

    The healthy adult human retina contains in its macular region a high concentration of blue-light absorbing carotenoid compounds, known as macular pigment (MP). Consisting of the carotenoids lutein, zeaxanthin, and meso-zeaxanthin, the MP is thought to shield the vulnerable tissue layers in the retina from light-induced damage through its function as an optical attenuator and to protect the tissue cells within its immediate vicinity through its function as a potent antioxidant. Autofluorescence imaging (AFI) is emerging as a viable optical method for MP screening of large subject populations, for tracking of MP changes over time, and for monitoring MP uptake in response to dietary supplementation. To investigate the influence of ocular media opacities on AFI-based MP measurements, in particular, the influence of lens cataracts, we conducted a clinical trial with a large subject population (93 subjects) measured before and after cataract surgery. General AFI image contrast, retinal blood vessel contrast, and presurgery lens opacity scores [Lens Opacities Classification System III (LOCS III)] were investigated as potential predictors for image degradation. These clinical results show that lens cataracts can severely degrade the achievable pixel contrasts in the AFI images, which results in nominal MP optical density levels that are artifactually reduced. While LOCS III scores and blood vessel contrast are found to be only a weak predictor for this effect, a strong correlation exists between the reduction factor and the image contrast, which can be quantified via pixel intensity histogram parameters. Choosing the base width of the histogram, the presence or absence of ocular media opacities can be determined and, if needed, the nominal MP levels can be corrected with factors depending on the strength of the opacity.

  20. Arab Libraries’ Web-based OPACs: An evaluative study in the light of IFLA’s Guidelines For Online Public Access Catalogue (OPAC Displays

    Directory of Open Access Journals (Sweden)

    Sherif Kamel Shaheen

    2005-03-01

    Full Text Available The research aims at evaluating Arabic Libraries’ Web-based Catalogues in the light of Principles and Recommendations published in: IFLA’s Guidelines For OPAC Displays (September 30, 2003 Draft For Worldwide Review. The total No. Of Recommendations reached” 38 “were categorized under three main titles, as follows: User Needs (12 recommendations, Content and arrangement Principle (25 recommendations, Standardization Principle (one recommendation However that number increased to reach 88 elements when formulated as evaluative criteria and included in the study’s checklist.

  1. Diagnostic performance of qualitative shear-wave elastography according to different color map opacities for breast masses

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hana; Youk, Ji Hyun, E-mail: jhyouk@yuhs.ac; Gweon, Hye Mi; Kim, Jeong-Ah; Son, Eun Ju

    2013-08-15

    Purpose: To compare the diagnostic performance of qualitative shear-wave elastography (SWE) according to three different color map opacities for breast masses Materials and methods: 101 patients aged 21–77 years with 113 breast masses underwent B-mode US and SWE under three different color map opacities (50%, 19% and 100%) before biopsy or surgery. Following SWE features were reviewed: visual pattern classification (pattern 1–4), color homogeneity (E{sub homo}) and six-point color score of maximum elasticity (E{sub col}). Combined with B-mode US and SWE, the likelihood of malignancy (LOM) was also scored. The area under the curve (AUC) was obtained by ROC curve analysis to assess the diagnostic performance under each color opacity. Results: A visual color pattern, E{sub homo}, E{sub col} and LOM scoring were significantly different between benign and malignant lesions under all color opacities (P < 0.001). For 50% opacity, AUCs of visual color pattern, E{sub col}, E{sub homo} and LOM scoring were 0.902, 0.951, 0.835 and 0.975. But, for each SWE feature, there was no significant difference in the AUC among three different color opacities. For all color opacities, visual color pattern and E{sub col} showed significantly higher AUC than E{sub homo}. In addition, a combined set of B-mode US and SWE showed significantly higher AUC than SWE alone for color patterns, E{sub homo}, but no significant difference was found in E{sub col}. Conclusion: Qualitative SWE was useful to differentiate benign from malignant breast lesion under all color opacities. The difference in color map opacity did not significantly influence diagnostic performance of SWE.

  2. Diagnostic performance of qualitative shear-wave elastography according to different color map opacities for breast masses

    International Nuclear Information System (INIS)

    Kim, Hana; Youk, Ji Hyun; Gweon, Hye Mi; Kim, Jeong-Ah; Son, Eun Ju

    2013-01-01

    Purpose: To compare the diagnostic performance of qualitative shear-wave elastography (SWE) according to three different color map opacities for breast masses Materials and methods: 101 patients aged 21–77 years with 113 breast masses underwent B-mode US and SWE under three different color map opacities (50%, 19% and 100%) before biopsy or surgery. Following SWE features were reviewed: visual pattern classification (pattern 1–4), color homogeneity (E homo ) and six-point color score of maximum elasticity (E col ). Combined with B-mode US and SWE, the likelihood of malignancy (LOM) was also scored. The area under the curve (AUC) was obtained by ROC curve analysis to assess the diagnostic performance under each color opacity. Results: A visual color pattern, E homo , E col and LOM scoring were significantly different between benign and malignant lesions under all color opacities (P < 0.001). For 50% opacity, AUCs of visual color pattern, E col , E homo and LOM scoring were 0.902, 0.951, 0.835 and 0.975. But, for each SWE feature, there was no significant difference in the AUC among three different color opacities. For all color opacities, visual color pattern and E col showed significantly higher AUC than E homo . In addition, a combined set of B-mode US and SWE showed significantly higher AUC than SWE alone for color patterns, E homo , but no significant difference was found in E col . Conclusion: Qualitative SWE was useful to differentiate benign from malignant breast lesion under all color opacities. The difference in color map opacity did not significantly influence diagnostic performance of SWE

  3. Radiative properties of stellar envelopes: Comparison of asteroseismic results to opacity calculations and measurements for iron and nickel

    International Nuclear Information System (INIS)

    Turck-Chieze, S.; Gilles, D.; Le Pennec, M.; Blenski, T.; Thais, F.; Bastiani-Ceccotti, S.; Blancard, C.; Caillaud, T.; Cosse, P.; Faussurier, G.; Gilleron, F.; Pain, J.C.; Reverdin, C.; Silvert, V.; Villette, B.; Busquet, M.; Colgan, J.; Guzik, J.; Kilcrease, D.P.; Magee, N.H.; Delahaye, F.; Zeippen, C.J.; Ducreta, J.E.; Fontes, C.J.; Harris, J.W.; Loisel, G.

    2013-01-01

    The international OPAC consortium consists of astrophysicists, plasma physicists and experimentalists who examine opacity calculations used in stellar physics that appear questionable and perform new calculations and laser experiments to understand the differences and improve the calculations. We report on iron and nickel opacities for envelopes of stars from 2 to 14 M and deliver our first conclusions concerning the reliability of the used calculations by illustrating the importance of the configuration interaction and of the completeness of the calculations for temperatures around 15-27 eV. (authors)

  4. An investigation of the opacity of high-Z mixture and implications for inertial confinement fusion hohlraum design

    International Nuclear Information System (INIS)

    Wang, P.; MacFarlane, J.J.; Orzechowski, T.J.

    1997-01-01

    We use an unresolved transition array model to investigate the opacities of high-Z materials and their mixtures which are of interest to indirect-drive inertial confinement fusion hohlraum design. In particular, we report on calculated opacities for pure Au, Gd, and Sm, as well as Au endash Sm and Au endash Gd mixtures. Our results indicate that mixtures of Au endash Gd and Au endash Sm can produce a significant enhancement in the Rosseland mean opacity. Radiation hydrodynamics simulations of Au radiation burnthrough are also presented, and compared with NOVA experimental data. copyright 1997 American Institute of Physics

  5. Influence of artificial accelerated aging on the color stability and opacity of composites of different shades.

    Science.gov (United States)

    Mundim, F M; Da Fonseca Roberti Garcia, L; Silva Sousa, A B; Cruvinel, D R; De Carvalho Panzeri Pires-De-Souza, F

    2010-10-01

    The aim of this study was to evaluate the influence of artificial accelerated aging on the color stability and opacity of composites of different shades. Four composites for direct use (Heliomolar, 4 Seasons, Tetric EvoCeram; QuiXfil) and one for indirect use (SR Adoro) in two shades were used: light (A2) and dark (C3 for direct, and D4 for indirect composite). QuiXfil was obtained in Universal shade. A Teflon matrix (12 X 2 mm) was used to obtain 54 specimens (N=6), which were submitted to color and opacity analysis (Spectrophotometer PCB 6807, Byk Gardner) before and after artificial accelerated aging for 384 hours. After the statistical analysis (2-way ANOVA - Bonferroni - PArtificial accelerated aging interfered in the optical properties assessed; however, the alterations seemed to be more related to the composites composition than to their shade.

  6. Femtosecond laser-assisted keratoplasty in a child with corneal opacity:case report

    Directory of Open Access Journals (Sweden)

    E. Yu. Markova

    2014-01-01

    Full Text Available Corneal opacities are the fourth cause of blindness world-wide. Over the past two centuries, various corneal transplantation (i.e., keratoplasty methods have been developed and improved. Nowadays, femtolaserssisted keratoplasty is one of most promising techniques. Femtosecond laser have several advantages that provide additional surgical benefits. Among them, no thermal injury, the ability to cut deeply on a single plane and to perform various corneal profiles should be mentioned. In children, corneal disorders are of special importance while femtosecondassisted keraatoplasty case reports are rare. Here, we describe femtosecond laserssisted penetrating keratoplasty in a girl with a rough central corneal opacity.

  7. 'Seeing the Dark': Grounding Phenomenal Transparency and Opacity in Precision Estimation for Active Inference.

    Science.gov (United States)

    Limanowski, Jakub; Friston, Karl

    2018-01-01

    One of the central claims of the Self-model Theory of Subjectivity is that the experience of being someone - even in a minimal form - arises through a transparent phenomenal self-model, which itself can in principle be reduced to brain processes. Here, we consider whether it is possible to distinguish between phenomenally transparent and opaque states in terms of active inference. We propose a relationship of phenomenal opacity to expected uncertainty or precision; i.e., the capacity for introspective attention and implicit mental action. Thus we associate introspective attention with the deployment of 'precision' that may render the perceptual evidence (for action) opaque, while treating transparency as a necessary aspect of beliefs about action, i.e., 'what I am' doing. We conclude by proposing how we may have to nuance our conception of minimal phenomenal selfhood and agency in light of this active inference conception of transparency-opacity.

  8. ‘Seeing the Dark’: Grounding Phenomenal Transparency and Opacity in Precision Estimation for Active Inference

    Science.gov (United States)

    Limanowski, Jakub; Friston, Karl

    2018-01-01

    One of the central claims of the Self-model Theory of Subjectivity is that the experience of being someone – even in a minimal form – arises through a transparent phenomenal self-model, which itself can in principle be reduced to brain processes. Here, we consider whether it is possible to distinguish between phenomenally transparent and opaque states in terms of active inference. We propose a relationship of phenomenal opacity to expected uncertainty or precision; i.e., the capacity for introspective attention and implicit mental action. Thus we associate introspective attention with the deployment of ‘precision’ that may render the perceptual evidence (for action) opaque, while treating transparency as a necessary aspect of beliefs about action, i.e., ‘what I am’ doing. We conclude by proposing how we may have to nuance our conception of minimal phenomenal selfhood and agency in light of this active inference conception of transparency-opacity. PMID:29780343

  9. Primary Pulmonary Mucosa-Associated Lymphoid Tissue Lymphoma with a Nodular Opacity: Report of a Case.

    Science.gov (United States)

    Yoshino, Naoyuki; Hirata, Tomomi; Takeuchi, Chie; Usuda, Jitsuo; Hosone, Masaru

    2017-01-01

    Herein, we describe our experience in treating a case of primary pulmonary mucosa-associated lymphoid tissue lymphoma detected as a nodular opacity. A 79-year-old man was referred to our hospital. Computed tomography showed a nodular opacity measuring 20 mm in diameter with regular margins in segment 5 of the right middle lobe of the lung. Although the bronchoscopic brush cytology result was class III, the patient was tentatively diagnosed with suspected mucosa-associated lymphoid tissue lymphoma. A thoracoscopic right middle lobectomy was performed. The pathological findings showed nodular proliferation of small to medium-sized, mature-appearing atypical lymphoid cells, lymphoepithelial lesions, and vague follicles suggesting follicular colonization in some areas. The patient was diagnosed with low-grade small B-cell lymphoma and mucosa-associated lymphoid tissue lymphoma. He has remained well to date, 23 months after surgery, without evidence of recurrence.

  10. Development of an Aerosol Opacity Retrieval Algorithm for Use with Multi-Angle Land Surface Images

    Science.gov (United States)

    Diner, D.; Paradise, S.; Martonchik, J.

    1994-01-01

    In 1998, the Multi-angle Imaging SpectroRadiometer (MISR) will fly aboard the EOS-AM1 spacecraft. MISR will enable unique methods for retrieving the properties of atmospheric aerosols, by providing global imagery of the Earth at nine viewing angles in four visible and near-IR spectral bands. As part of the MISR algorithm development, theoretical methods of analyzing multi-angle, multi-spectral data are being tested using images acquired by the airborne Advanced Solid-State Array Spectroradiometer (ASAS). In this paper we derive a method to be used over land surfaces for retrieving the change in opacity between spectral bands, which can then be used in conjunction with an aerosol model to derive a bound on absolute opacity.

  11. Limb-darkening opacity experiment using a laser-heated plasma

    International Nuclear Information System (INIS)

    Hoffman, N.M.; Miller, L.W.; Mack, J.M.

    1978-10-01

    The limb-darkening technique, a method for measuring monochromatic opacity information, which has had successful astrophysical applications, is reviewed. The application of the technique to laser-produced plasmas in materials and regimes of temperature and density of interest to weapons designers is discussed, and the magnitude of the limb-darkening effect in such situations is estimated. Finally, an experimental study, now in progress, to evaluate the feasibility of this approach is described. 10 figures

  12. Conceptual design of initial opacity experiments on the national ignition facility

    Science.gov (United States)

    Heeter, R. F.; Bailey, J. E.; Craxton, R. S.; Devolder, B. G.; Dodd, E. S.; Garcia, E. M.; Huffman, E. J.; Iglesias, C. A.; King, J. A.; Kline, J. L.; Liedahl, D. A.; McKenty, P. W.; Opachich, Y. P.; Rochau, G. A.; Ross, P. W.; Schneider, M. B.; Sherrill, M. E.; Wilson, B. G.; Zhang, R.; Perry, T. S.

    2017-02-01

    Accurate models of X-ray absorption and re-emission in partly stripped ions are necessary to calculate the structure of stars, the performance of hohlraums for inertial confinement fusion and many other systems in high-energy-density plasma physics. Despite theoretical progress, a persistent discrepancy exists with recent experiments at the Sandia Z facility studying iron in conditions characteristic of the solar radiative-convective transition region. The increased iron opacity measured at Z could help resolve a longstanding issue with the standard solar model, but requires a radical departure for opacity theory. To replicate the Z measurements, an opacity experiment has been designed for the National Facility (NIF). The design uses established techniques scaled to NIF. A laser-heated hohlraum will produce X-ray-heated uniform iron plasmas in local thermodynamic equilibrium (LTE) at temperatures eV and electron densities 21~\\text{cm}-3$ . The iron will be probed using continuum X-rays emitted in a ps, diameter source from a 2 mm diameter polystyrene (CH) capsule implosion. In this design, of the NIF beams deliver 500 kJ to the mm diameter hohlraum, and the remaining directly drive the CH capsule with 200 kJ. Calculations indicate this capsule backlighter should outshine the iron sample, delivering a point-projection transmission opacity measurement to a time-integrated X-ray spectrometer viewing down the hohlraum axis. Preliminary experiments to develop the backlighter and hohlraum are underway, informing simulated measurements to guide the final design.

  13. Effect of cigarette smoking on the detection of small radiographic opacities in inorganic dust diseases

    International Nuclear Information System (INIS)

    Blanc, P.D.; Gamsu, G.

    1988-01-01

    Whether cigarette smoking can cause radiographic opacities indistinguishable from those due to pneumoconiosis remains controversial. The situation becomes clearer when one limits the abnormalities to those that can be standardized under the International Labour Office (ILO) classification system. The bulk of the evidence indicates that, using the ILO system, cigarette smoking alone is not associated with radiographic opacities that would be mistaken for pneumoconiosis with sufficient frequency to be of any practical importance. The effects of cigarette smoking, as a cofactor, in conjunction with occupational dust exposure depend on the type of dust. No relationship has been convincingly demonstrated for coal dust or silica. Only with asbestos exposure does there appear to be a significant cigarette smoking-associated increase in the frequency of irregular radiographic opacities. This increase does not appear to translate into a restrictive impairment in pulmonary function. The limited information available indicates that the features of asbestosis on high-resolution computed tomography are not similarly related to cigarette smoking. Additional research is needed to substantiate the relationship between smoking and occupational exposure to dust of many types, and also the possible imaging and pathophysiologic significance of their interactions. 47 references

  14. Target simulations with SCROLL non-LTE opacity/emissivity databases.

    Science.gov (United States)

    Klapisch, M.; Colombant, D.; Bar-Shalom, A.

    2001-10-01

    SCROLL[1], a collisional radiative model and code based on superconfigurations, is able to compute high Z non-LTE opacities and emissivities accurately and efficiently. It was used to create opacity/emissivity databases for Pd, Lu, Au on a 50 temperatures/80 densities grid. Incident radiation field was shown to have no effect on opacities in the case of interest, and was not taken into account. These databases were introduced in the hydrocode FAST1D[2]. SCROLL also gives an ionization temperature Tz which is used in FAST1D to obtain non-LTE corrections to the equation of state. Results will be compared to those of a previous version using Busquet’s algorithm[3]. Work supported by USDOE under a contract with NRL. [1] A. Bar-Shalom, J. Oreg and M. Klapisch, J. Quant. Spectrosc. Radiat. Transfer, 65, 43(2000). [2] J. H. Gardner, A. J. Schmitt, J. P. Dahlburg, C. J. Pawley, S. E. Bodner, S. P. Obenschain, V. Serlin and Y. Aglitskiy, Phys. Plasmas, 5, 1935 (1998). [3] M. Busquet, Phys. Fluids B, 5, 4191 (1993).

  15. Random sampling technique for ultra-fast computations of molecular opacities for exoplanet atmospheres

    Science.gov (United States)

    Min, M.

    2017-10-01

    Context. Opacities of molecules in exoplanet atmospheres rely on increasingly detailed line-lists for these molecules. The line lists available today contain for many species up to several billions of lines. Computation of the spectral line profile created by pressure and temperature broadening, the Voigt profile, of all of these lines is becoming a computational challenge. Aims: We aim to create a method to compute the Voigt profile in a way that automatically focusses the computation time into the strongest lines, while still maintaining the continuum contribution of the high number of weaker lines. Methods: Here, we outline a statistical line sampling technique that samples the Voigt profile quickly and with high accuracy. The number of samples is adjusted to the strength of the line and the local spectral line density. This automatically provides high accuracy line shapes for strong lines or lines that are spectrally isolated. The line sampling technique automatically preserves the integrated line opacity for all lines, thereby also providing the continuum opacity created by the large number of weak lines at very low computational cost. Results: The line sampling technique is tested for accuracy when computing line spectra and correlated-k tables. Extremely fast computations ( 3.5 × 105 lines per second per core on a standard current day desktop computer) with high accuracy (≤1% almost everywhere) are obtained. A detailed recipe on how to perform the computations is given.

  16. An Analysis of Source Tilting and Sub-cell Opacity Sampling for IMC

    Energy Technology Data Exchange (ETDEWEB)

    Wollaeger, Ryan T. [Los Alamos National Laboratory; Urbatsch, Todd J. [Los Alamos National Laboratory; Wollaber, Allan B. [Los Alamos National Laboratory; Densmore, Jeffery D. [Los Alamos National Laboratory

    2012-08-02

    Implicit Monte Carlo (IMC) is a stochastic method for solving the radiative transfer equations for multiphysics application with the material in local thermodynamic equilibrium. The IMC method employs a fictitious scattering term that is computed from an implicit discretization of the material temperature equation. Unfortunately, the original histogram representation of the temperature and opacity with respect to the spatial domain leads to nonphysically fast propagation of radiation waves through optically thick material. In the past, heuristic source tilting schemes have been used to mitigate the numerical teleportation error of the radiation particles in IMC that cause this overly rapid radiation wave propagation. While improving the material temperature profile throughout the time duration, these tilting schemes alone do not generally alleviate the teleportation error to suitable levels. Another means of potentially reducing teleportation error in IMC is implementing continuous sub-cell opacities based on sub-cell temperature profiles. We present here an analysis of source tilting and continuous sub-cell opacity sampling applied to various discretizations of the temperature equation. Through this analysis, we demonstrate that applying both heuristics does not necessarily yield more accurate results if the discretization of the material equation is inconsistent with the Monte Carlo sub-cell transport.

  17. Configuration interaction effect on open M shell Fe and Ni LTE spectral opacities, Rosseland and Planck means

    International Nuclear Information System (INIS)

    Gilles, D; Busquet, M; Gilleron, F; Pain, J-C; Klapisch, M

    2016-01-01

    We have recently shown that iron and nickel open M-shell opacity spectra, up to Δn = 2 are very sensitive to Configuration Interaction (CI) treatments at temperature around 15 eV and for various densities. To do so we had compared extensive CI calculations obtained with two opacity codes HULLAC-v9 and SCO-RCG. In this work we extend these comparisons to a first evaluation of CI effects on Rosseland and Planck means. (paper)

  18. GASEOUS MEAN OPACITIES FOR GIANT PLANET AND ULTRACOOL DWARF ATMOSPHERES OVER A RANGE OF METALLICITIES AND TEMPERATURES

    Energy Technology Data Exchange (ETDEWEB)

    Freedman, Richard S. [SETI Institute, Mountain View, CA (United States); Lustig-Yaeger, Jacob [Department of Physics, University of California, Santa Cruz, CA 95064 (United States); Fortney, Jonathan J. [Department of Astronomy and Astrophysics, University of California, Santa Cruz, CA 95064 (United States); Lupu, Roxana E.; Marley, Mark S. [Space Science and Astrobiology Division, NASA Ames Research Center, Moffett Field, CA (United States); Lodders, Katharina, E-mail: Richard.S.Freedman@nasa.gov [Planetary Chemistry Laboratory, Washington University, St. Louis, MO (United States)

    2014-10-01

    We present new calculations of Rosseland and Planck gaseous mean opacities relevant to the atmospheres of giant planets and ultracool dwarfs. Such calculations are used in modeling the atmospheres, interiors, formation, and evolution of these objects. Our calculations are an expansion of those presented in Freedman et al. to include lower pressures, finer temperature resolution, and also the higher metallicities most relevant for giant planet atmospheres. Calculations span 1 μbar to 300 bar, and 75-4000 K, in a nearly square grid. Opacities at metallicities from solar to 50 times solar abundances are calculated. We also provide an analytic fit to the Rosseland mean opacities over the grid in pressure, temperature, and metallicity. In addition to computing mean opacities at these local temperatures, we also calculate them with weighting functions up to 7000 K, to simulate the mean opacities for incident stellar intensities, rather than locally thermally emitted intensities. The chemical equilibrium calculations account for the settling of condensates in a gravitational field and are applicable to cloud-free giant planet and ultracool dwarf atmospheres, but not circumstellar disks. We provide our extensive opacity tables for public use.

  19. Dependent lung opacity at thin-section CT: evaluation by spirometrically-gated CT of the influence of lung volume

    International Nuclear Information System (INIS)

    Lee, Ki Nam; Yoon, Seong Kuk; Sohn, Choon Hee; Choi, Pil Jo; Webb, W. Richard

    2002-01-01

    To evaluate the influence of lung volume on dependent lung opacity seen at thin-section CT. In thirteen healthy volunteers, thin-section CT scans were performed at three levels (upper, mid, and lower portion of the lung) and at different lung volumes (10, 30, 50, and 100% vital capacity), using spirometric gated CT. Using a three-point scale, two radiologists determined whether dependent opacity was present, and estimated its degree. Regional lung attenuation at a level 2 cm above the diaphragm was determined using semiautomatic segmentation, and the diameter of a branch of the right lower posterior basal segmental artery was measured at each different vital capacity. At all three anatomic levels, dependent opacity occurred significantly more often at lower vital capacities (10, 30%) than at 100% vital capacity (p = 0.001). Visually estimated dependent opacity was significantly related to regional lung attenuation (p < 0.0001), which in dependent areas progressively increased as vital capacity decreased (p < 0.0001). The presence of dependent opacity and regional lung attenuation of a dependent area correlated significantly with increased diameter of a segmental arterial branch (r = 0.493 and p = 0.0002; r = 0.486 and p 0.0003, respectively). Visual estimation and CT measurements of dependent opacity obtained by semiautomatic segmentation are significantly influenced by lung volume and are related to vascular diameter

  20. Diagnostic performance of qualitative shear-wave elastography according to different color map opacities for breast masses.

    Science.gov (United States)

    Kim, Hana; Youk, Ji Hyun; Gweon, Hye Mi; Kim, Jeong-Ah; Son, Eun Ju

    2013-08-01

    To compare the diagnostic performance of qualitative shear-wave elastography (SWE) according to three different color map opacities for breast masses 101 patients aged 21-77 years with 113 breast masses underwent B-mode US and SWE under three different color map opacities (50%, 19% and 100%) before biopsy or surgery. Following SWE features were reviewed: visual pattern classification (pattern 1-4), color homogeneity (Ehomo) and six-point color score of maximum elasticity (Ecol). Combined with B-mode US and SWE, the likelihood of malignancy (LOM) was also scored. The area under the curve (AUC) was obtained by ROC curve analysis to assess the diagnostic performance under each color opacity. A visual color pattern, Ehomo, Ecol and LOM scoring were significantly different between benign and malignant lesions under all color opacities (Pbreast lesion under all color opacities. The difference in color map opacity did not significantly influence diagnostic performance of SWE. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  1. Effects of adhesive used as modeling liquid on the stability of the color and opacity of composites.

    Science.gov (United States)

    Araujo, Fernanda Santos; Barros, Mellany Cristie Ramos; Santana, Márcia Luciana Carregosa; de Jesus Oliveira, Ludmila Smith; Silva, Paula Fernanda Damasceno; Lima, Giana da Silveira; Faria-E-Silva, André Luis

    2018-04-01

    This study evaluated the effects of adhesive type used as modeling liquid on the stability of the color and opacity of composites submitted to thermal cycling in staining solutions followed by a bleaching procedure. Thirty cylinder-shaped composite specimens (10 mm diameter × 1.5 mm thickness) were built using or not using (control) an adhesive (Adper Universal or Scotchbond Multipurpose) as the modeling liquid. After polishing procedures, the color and opacity were measured, and the specimens were submitted to 200 thermal cycles with 10 s of dwell time in baths of grape juice at 5°C, water at 37°C, and coffee at 55°C. Changes in opacity and color caused by the staining solutions were measured. Then, the specimens were bleached with 35% hydrogen peroxide for 45 minutes followed by color/opacity measurements. Data were analyzed by ANOVA and Tukey's test (α = 0.05). The use of modeling liquids did not affect the initial color and opacity of composite. Reduced changes to color (E 00  = 3.44) and opacity (+2.67%) were observed for specimens modeled using Adper Universal. Bleaching procedures reduced the color (E 00  = 1.9-3.8) and opacity (-2.3 to 3.1%) alterations caused by staining solutions but were unable to restore the values observed at baseline. The use of universal adhesive as modeling liquid significantly reduced the color and opacity changes caused by staining solutions, and the bleaching procedure partially re-established the opacity and color of the composites. This study evaluates whether using adhesive systems for modeling a composite affects the color and opacity changes caused by staining solutions followed by a bleaching procedure. The findings suggest that the use of a universal adhesive as modeling liquid can reduce the alterations in optical properties caused by staining solutions, and the application of high-concentrated hydrogen peroxide over the composite reduce the color changes without fully recover the initial color. © 2018

  2. Computed tomographic features of 23 sporadic cases with Legionella pneumophila pneumonia

    International Nuclear Information System (INIS)

    Yu Hui; Higa, Futoshi; Hibiya, Kenji; Furugen, Makoto; Sato, Yoko; Shinzato, Takashi; Haranaga, Shusaku; Yara, Satomi; Tateyama, Masao; Fujita, Jiro; Li, Huiping

    2010-01-01

    Objective: To describe the chest computed tomographic (CT) findings of Legionella pneumophila pneumonia. Methods: CT scans obtained from 23 sporadic cases of L. pneumophila pneumonia were retrospectively reviewed. Chest CT findings were analyzed with regard to the patterns and distributions of pulmonary abnormalities. We also analyzed the histopathology of lungs from guinea pigs with experimentally induced L. pneumophila pneumonia. Results: Consolidation and ground-glass opacity (GGO) were the main findings of CT scans in L. pneumophila pneumonia. The distribution of opacities was categorized as non-segmental (n = 20) and segmental (n = 4). Non-segmental distribution may follow an onset of segmental distribution. Pleural effusion was observed in 14 (58.3%) patients, of which 13 were accompanied with non-segmental distribution. Abscess formation was observed in only one immunocompromised patient. In the animal pneumonia model, the lesions comprised of terminal bronchioles, alveolar spaces, and interstitia. Small bacilli were observed to be contained by many macrophages within the alveoli. Conclusion: Non-segmental distribution was significantly more frequent than segmental distribution in L. pneumophila pneumonia. It is possible that L. pneumophila infection initially results in segmental pneumonia, which progresses to typical non-segmental distribution.

  3. Computed tomographic features of 23 sporadic cases with Legionella pneumophila pneumonia

    Energy Technology Data Exchange (ETDEWEB)

    Yu Hui [Department of Respiratory Diseases, Shanghai Pneumology Hospital, Tongji University, Shanghai (China); Higa, Futoshi; Hibiya, Kenji; Furugen, Makoto [Department of Medicine and Therapeutics, Control and Prevention of Infectious Diseases (First Department of Internal Medicine), Faculty of Medicine, University of the Ryukyus, Okinawa (Japan); Sato, Yoko [Tomishiro Chuo Hospital, Okinawa (Japan); Shinzato, Takashi [Nakagami General Hospital, Okinawa (Japan); Haranaga, Shusaku; Yara, Satomi; Tateyama, Masao [Department of Medicine and Therapeutics, Control and Prevention of Infectious Diseases (First Department of Internal Medicine), Faculty of Medicine, University of the Ryukyus, Okinawa (Japan); Fujita, Jiro, E-mail: fujita@med.u-ryukyu.ac.j [Department of Medicine and Therapeutics, Control and Prevention of Infectious Diseases (First Department of Internal Medicine), Faculty of Medicine, University of the Ryukyus, Okinawa (Japan); Li, Huiping [Department of Respiratory Diseases, Shanghai Pneumology Hospital, Tongji University, Shanghai (China)

    2010-06-15

    Objective: To describe the chest computed tomographic (CT) findings of Legionella pneumophila pneumonia. Methods: CT scans obtained from 23 sporadic cases of L. pneumophila pneumonia were retrospectively reviewed. Chest CT findings were analyzed with regard to the patterns and distributions of pulmonary abnormalities. We also analyzed the histopathology of lungs from guinea pigs with experimentally induced L. pneumophila pneumonia. Results: Consolidation and ground-glass opacity (GGO) were the main findings of CT scans in L. pneumophila pneumonia. The distribution of opacities was categorized as non-segmental (n = 20) and segmental (n = 4). Non-segmental distribution may follow an onset of segmental distribution. Pleural effusion was observed in 14 (58.3%) patients, of which 13 were accompanied with non-segmental distribution. Abscess formation was observed in only one immunocompromised patient. In the animal pneumonia model, the lesions comprised of terminal bronchioles, alveolar spaces, and interstitia. Small bacilli were observed to be contained by many macrophages within the alveoli. Conclusion: Non-segmental distribution was significantly more frequent than segmental distribution in L. pneumophila pneumonia. It is possible that L. pneumophila infection initially results in segmental pneumonia, which progresses to typical non-segmental distribution.

  4. From stellar plasmas to laboratory plasmas: application to X and XUV opacity measurements

    International Nuclear Information System (INIS)

    Loisel, G.

    2011-01-01

    The general context of this thesis is the one of radiative properties of high energy density matter. Energy densities involved (>10 11 J/cm 3 ) implies that a large part of energy exchange goes through radiation-matter interactions. My studies deal with spectral opacity, a fundamental parameter for modelling stellar interiors and constitute a propitious observable to experimental tests of theoretical descriptions of hot and dense plasmas physics. Although the main application of my work is stellar plasmas it can be useful for plasma diagnostics in inertial confinement fusion. My work activities are centred on the experimental study of opacities of plasmas at local thermodynamic equilibrium for temperature conditions of a few tens eV (a few 100000 K) and a few mg/cm 3 in matter density. Plasmas are obtained in conditions as homogenous as possible using the radiative heating of a laser-irradiated cavity. Heating is provided through a laser beam of high energy (100-300 J) and with relatively long pulse duration of a few nanosecond. For such measurements we could benefit from the LULI lasers configuration coupling the nanosecond beam with a picosecond one used to perform on a short duration the measurement of the plasma transmission. The use of short pulse laser to produce a short time radiography beam was a first achievement for this kind of experience. In the spectral range of keV photons, absorbing transitions 2p-3d or 3d-4f of elements of moderate or high atomic number have been probed. They present absorption structures which shape results mainly of the competition between spin-orbit splitting and statistical broadening effects. It appeared that this competition depends strongly on the atomic number Z. Thus for similar plasma parameters we explored opacities of Iron, Nickel, Copper and Germanium (Z around 30) in a first series of measurement and the one of Barium, Samarium and Gadolinium (Z around 60) in a second campaign

  5. A test of lens opacity as an indicator of preclinical Alzheimer Disease.

    Science.gov (United States)

    Bei, Ling; Shui, Ying-Bo; Bai, Fang; Nelson, Suzanne K; Van Stavern, Gregory P; Beebe, David C

    2015-11-01

    Previous studies reported that characteristic lens opacities were present in Alzheimer Disease (AD) patients postmortem. We therefore determined whether cataract grade or lens opacity is related to the risk of Alzheimer dementia in participants who have biomarkers that predict a high risk of developing the disease. AD biomarker status was determined by positron emission tomography-Pittsburgh compound B (PET-PiB) imaging and cerebrospinal fluid (CSF) levels of Aβ42. Cognitively normal participants with a clinical dementia rating of zero (CDR = 0; N = 40) or with slight evidence of dementia (CDR = 0.5; N = 2) were recruited from longitudinal studies of memory and aging at the Washington University Knight Alzheimer's Disease Research Center. The age, sex, race, cataract type and cataract grade of all participants were recorded and an objective measure of lens light scattering was obtained for each eye using a Scheimpflug camera. Twenty-seven participants had no biomarkers of Alzheimer dementia and were CDR = 0. Fifteen participants had biomarkers indicating increased risk of AD, two of which were CDR = 0.5. Participants who were biomarker positive were older than those who were biomarker negative. Biomarker positive participants had more advanced cataracts and increased cortical light scattering, none of which reached statistical significance after adjustment for age. We conclude that cataract grade or lens opacity is unlikely to provide a non-invasive measure of the risk of developing Alzheimer dementia. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Effect of Biodiesel of Spent Cooking Oil Addition at Diesel Fuel to Opacity and Gas Emission Throw Away of CO, CO2 and HC

    International Nuclear Information System (INIS)

    Setyadji, Moch; Endang Susiantini

    2007-01-01

    Investigation of biodiesel spent cooking oil addition effect at diesel fuel to opacity and gas emission throw away on various engine rotation speed has been done. The variables observed were fuel specific used i.e. pure diesel fuel, biodiesel mix 5% (B5), mix 10% (B10), mix 15% (B15), mix 20% (B20) and engine rotation speed. Gas emission throw away observed were CO, CO 2 , HC and opacity. Opacity and gas emission throwaway were observed by Opacity Sagem apparatus and gas analyzer. Result of experiment showed that biodiesel addition at diesel fuel was very decreasing opacity and gas emission throw away. The opacity lowest on B20, gas emission throw away lowest of CO on B10, CO 2 on B10 and HC on B20. (author)

  7. Calculation of opacities and emissivities for carbon plasmas under NLTE and LTE conditions

    International Nuclear Information System (INIS)

    Gil, J.M.; Rodriguez, R.; Florido, R.; Rubiano, J.G.; Martel, P.; Sauvan, P.; Minguez, E.

    2006-01-01

    We calculate different optical properties for carbon plasma in a wide range of temperatures and densities by using ATOM3R-OP code which has been recently developed. In this code we have implemented the rate equations, the Saha equation (for local thermodynamic equilibrium) and the coronal equilibrium model. We have calculated average ionizations, level populations, opacities and emissivities and we focus our study on the identification with our code of coronal equilibrium, non-local thermodynamic equilibrium and local thermodynamic equilibrium regions for this kind of plasma. Moreover, we analyse the differences in the optical properties when they are calculated in non-local thermodynamic equilibrium and local thermodynamic equilibrium. (authors)

  8. Study of Opacity Effects on Emission Lines at EXTRAP T2R RFP

    Science.gov (United States)

    Stancalie, Viorica; Rachlew, Elisabeth

    We have investigated the influence of opacity on hydrogen (H-α and Ly-β) and Li-like oxygen emission lines from the EXTRAP T2R reversed field pinch. We used the Atomic Data Analysis System (AzDAS) based on the escape factor approximation for radiative transfer to calculate metastable and excited population densities via a collisional-radiative model. Population escape factor, emergent escape factor and modified line profiles are plotted vs. optical depth. The simulated emission line ratios in the density/temperature plane are in good agreement with experimental data for electron density and temperature measurements.

  9. Relaxing the Small Particle Approximation for Dust-grain opacities in Carbon-star Wind Models

    OpenAIRE

    Mattsson, Lars; Höfner, Susanne

    2010-01-01

    We have computed wind models with time-dependent dust formation and grain-size dependent opacities, where (1) the problem is simplified by assuming a fixed dust-grain size, and where (2) the radiation pressure efficiency is approximated using grain sizes based on various means of the actual grain size distribution. It is shown that in critical cases, the effect of grain sizes can be significant. For well-developed winds, however, the effects on the mass-loss rate and the wind speed are small.

  10. Atomic data base and the U.K.-U.S. opacity project

    Science.gov (United States)

    Pradhan, A. K.

    1988-08-01

    With the primary aim of calculating stellar envelope opacities, a joint international collaboration is under way for the calculation of basic atomic data for radiative processes: oscillator strengths, photoionization cross sections, energy levels, radiative damping constants (including line broadening). Atomic calculations have been completed for the first ten isoelectronic sequences, H-like to Ne-like, going up to iron, and work is in progress on the third and fourth row atoms and isosequences. The close-coupling approximation is employed throughout using a new version of the R-matrix method. Particular emphasis is placed on the detailed resolution of the autoionization structures in the bound-free continuum.

  11. CLINICAL OUTCOME OF PENETRATING KERATOPLASTY IN CORNEAL OPACITIES OF DIFFERENT AETIOLOGY- A CLINICAL STUDY

    Directory of Open Access Journals (Sweden)

    Dipak Bhuyan

    2017-01-01

    Full Text Available BACKGROUND Corneal transplantation or grafting is an operation in which abnormal corneal host tissue is replaced by healthy donor cornea. According to the World Health Organization (WHO, corneal diseases are among the major causes of vision loss and blindness in the world today after cataract and glaucoma. The aim of the study is to- 1. Evaluate the different aetiology of corneal opacity including active infective aetiology as indicated for penetrating keratoplasty. 2. Determine the clinical outcome of penetrating keratoplasty in relation to graft survival, graft rejection and peri-operative complications in different aetiology groups. 3. Determine the final visual outcome. MATERIALS AND METHODS Candidates for keratoplasty were selected from- 1. Eye Bank of Regional Institute of Ophthalmology (R.I.O. 2. R.I.O OPD. The study period was from September 2014 to August 2015. 30 cases were taken in the study. Descriptive statistics were applied to analyse the data wherever necessary. RESULTS 34.6±19.73 yrs. (mean±SD was the mean age at which transplants were done in the study. Out of total 30 cases, 13 (43.33% and 17 (56.66% were male and female, respectively. The different indications for penetrating keratoplasty are- Post ulcer corneal opacity in 14 cases (46.66%, posttraumatic corneal opacity 9 cases (30%, pseudophakic bullous keratopathy 4 cases (13.33%, corneal dystrophy in 2 cases (6.66% and non-healing corneal ulcer in 1 case (3.33%. 16 cases (53.33% showed clear graft till the last follow up while 11 (33.33% cases showed partially clear graft resulting in improved visual outcome while 3 cases (10.00% of the grafts were opaque due to graft failure. CONCLUSION The major indications for penetrating keratoplasty in this part of the world are post ulcer and posttraumatic corneal opacity and majority of them are illiterate agricultural workers who failed to get adequate treatment on time. Graft survival rate is high, which can be attributed to the

  12. Calculation of opacities and emissivities for carbon plasmas under NLTE and LTE conditions

    Energy Technology Data Exchange (ETDEWEB)

    Gil, J.M.; Rodriguez, R.; Florido, R.; Rubiano, J.G.; Martel, P. [Las Palmas de Gran Canaria Univ., Dept. de Fisica (Spain); Sauvan, P. [Universidad Nacional de Educacion a Distancia, Dept. de Ingenieria Energetica, Madrid (Spain); Minguez, E. [Madrid Univ. Politecnica, Instituto de Fusion Nuclear-DENIM (Spain)

    2006-06-15

    We calculate different optical properties for carbon plasma in a wide range of temperatures and densities by using ATOM3R-OP code which has been recently developed. In this code we have implemented the rate equations, the Saha equation (for local thermodynamic equilibrium) and the coronal equilibrium model. We have calculated average ionizations, level populations, opacities and emissivities and we focus our study on the identification with our code of coronal equilibrium, non-local thermodynamic equilibrium and local thermodynamic equilibrium regions for this kind of plasma. Moreover, we analyse the differences in the optical properties when they are calculated in non-local thermodynamic equilibrium and local thermodynamic equilibrium. (authors)

  13. Predicting adenocarcinoma recurrence using computational texture models of nodule components in lung CT

    International Nuclear Information System (INIS)

    Depeursinge, Adrien; Yanagawa, Masahiro; Leung, Ann N.; Rubin, Daniel L.

    2015-01-01

    Purpose: To investigate the importance of presurgical computed tomography (CT) intensity and texture information from ground-glass opacities (GGO) and solid nodule components for the prediction of adenocarcinoma recurrence. Methods: For this study, 101 patients with surgically resected stage I adenocarcinoma were selected. During the follow-up period, 17 patients had disease recurrence with six associated cancer-related deaths. GGO and solid tumor components were delineated on presurgical CT scans by a radiologist. Computational texture models of GGO and solid regions were built using linear combinations of steerable Riesz wavelets learned with linear support vector machines (SVMs). Unlike other traditional texture attributes, the proposed texture models are designed to encode local image scales and directions that are specific to GGO and solid tissue. The responses of the locally steered models were used as texture attributes and compared to the responses of unaligned Riesz wavelets. The texture attributes were combined with CT intensities to predict tumor recurrence and patient hazard according to disease-free survival (DFS) time. Two families of predictive models were compared: LASSO and SVMs, and their survival counterparts: Cox-LASSO and survival SVMs. Results: The best-performing predictive model of patient hazard was associated with a concordance index (C-index) of 0.81 ± 0.02 and was based on the combination of the steered models and CT intensities with survival SVMs. The same feature group and the LASSO model yielded the highest area under the receiver operating characteristic curve (AUC) of 0.8 ± 0.01 for predicting tumor recurrence, although no statistically significant difference was found when compared to using intensity features solely. For all models, the performance was found to be significantly higher when image attributes were based on the solid components solely versus using the entire tumors (p < 3.08 × 10 −5 ). Conclusions: This study

  14. Digitisation of films and texture analysis for digital classification of pulmonary opacities

    International Nuclear Information System (INIS)

    Desaga, J.F.; Dengler, J.; Wolf, T.; Engelmann, U.; Scheppelmann, D.; Meinzer, H.P.

    1988-01-01

    The study aimed at evaluating the effect of different methods of digitisation of radiographic films on the digital classification of pulmonary opacities. Test sets from the standard of the International Labour Office (ILO) Classification of Radiographs of Pneumoconiosis were prepared by film digitsation using a scanning microdensitometer or a video digitiser based on a personal computer equipped with a real time digitiser board and a vidicon or a Charge Coupled Device (CCD) camera. Seven different algorithms were used for texture analysis resulting in 16 texture parameters for each region. All methods used for texture analysis were independent of the mean grey value level and the size of the image analysed. Classification was performed by discriminant analysis using the classes from the ILO classification. A hit ratio of at least 85% was achieved for a digitisation by scanner digitisation or the vidicon, while the corresponding results of the CCD camera were significantly less good. Classification by texture analysis of opacities of chest X-rays of pneumoconiosis digitised by a personal computer based video digitiser and a vidicon are of equal quality compared to digitisation by a scanning microdensitometer. Correct classification of 90% was achieved via the described statistical approach. (orig.) [de

  15. Design for LTE EOS and opacity experiments using supersonic radiation waves

    Science.gov (United States)

    Tierney, T. E.; Peterson, R. R.; Tierney, H. E.

    2007-11-01

    Opacity and EOS at 100-200 eV are important physical parameters in ICF experiments. We describe an experiment design that uses the supersonic propagation of hohlraum radiation in foams to isochorically heat samples. Laser and Z-pinch experiments frequently use 150 to 220-eV quasi-blackbody emission from hohlraums to drive physics experiments. A foam target encapsulated in a gold-wall cylinder is placed next to the hohlraum. The low density and opacity foam captures some hohlraum emission and generates a supersonically-propagating radiation wave. The material heated by the wave is cooler towards the high-albedo gold wall. Modeling and past measurements show that core regions of the foam have small thermal gradients. We place a small, thin sample (e.g., Al, Si, or Fe) in the thermally-uniform region. X-ray emission of tracers and the sample as well as quasi-continuum x-ray absorption will be measured using time-resolved x-ray spectroscopy. The foam's EOS can be measured to ±5% by blast waves with a well characterized drive. This experiment could use the OMEGA, Z-Beamlet, and/or ZR facilities to explore temperature-dependent conditions.

  16. A Protective Eye Shield for Prevention of Media Opacities during Small Animal Ocular Imaging

    Science.gov (United States)

    Bell, Brent A.; Kaul, Charles; Hollyfield, Joe G.

    2014-01-01

    Optical coherence tomography (OCT), scanning laser ophthalmoscopy (SLO) and other non-invasive imaging techniques are increasingly used in eye research to document disease-related changes in rodent eyes. Corneal dehydration is a major contributor to the formation of ocular opacities that can limit the repeated application of these techniques to individual animals. General anesthesia is usually required for imaging, which is accompanied by the loss of the blink reflex. As a consequence, the tear film cannot be maintained, drying occurs and the cornea becomes dehydrated. Without supplemental hydration, structural damage to the cornea quickly follows. Soon thereafter, anterior lens opacities can also develop. Collectively these changes ultimately compromise image quality, especially for studies involving repeated use of the same animal over several weeks or months. To minimize these changes, a protective shield was designed for mice and rats that prevent ocular dehydration during anesthesia. The eye shield, along with a semi-viscous ophthalmic solution, is placed over the corneas as soon as the anesthesia immobilizes the animal. Eye shields are removed for only the brief periods required for imaging and then reapplied before the fellow eye is examined. As a result, the corneal surface of each eye is exposed only for the time required for imaging. The device and detailed methods described here minimize the corneal and lens changes associated with ocular surface desiccation. When these methods are used consistently, high quality images can be obtained repeatedly from individual animals. PMID:25245081

  17. AKSES JENIS DOKUMEN PADA BASIS DATA TERPADU: SUATU TINJAUAN TERHADAP OPAC DI PDII-LIPI

    Directory of Open Access Journals (Sweden)

    Ade Kohar

    2012-07-01

    Full Text Available Integrated data base is a data base records bibliographic data of several types of document like textbook, periodicals, proceedings, research report, thesis, and article. Purposes of this study were to investigate document type description and searching strategy in integrated data base of online public access catalogs (OPAC in PDII-LIPI, and to know user opinion about that data base existence. It used observation and interviews to 100 data base users to collect data. Result of this study stated that document type description in OPAC was not indexed, so users couldn't do information searching of special type of document directly in the data base. There was only one method could be used to search information of special type of document. User could select it from some information records on the computer screen as the result of document title, author name or subject searching in the data base. This information access method was not efficient. So document type description and indexing was an important factor and should be done in information retrieval system using integrated data base. But respondent majority (84% in PDII-LIPI stated that they liked using separated data base to search information of special type of document.

  18. Constraining the Dust Opacity Law in Three Small and Isolated Molecular Clouds

    Energy Technology Data Exchange (ETDEWEB)

    Webb, K. A.; Thanjavur, K. [Department of Physics and Astronomy, 3800 Finnerty Road, University of Victoria, Victoria, BC, V8P 5C2 (Canada); Di Francesco, J. [National Research Council of Canada, Herzberg Institute of Astrophysics, 5071 West Saanich Road, Victoria, BC, V9E 2E7 (Canada); Sadavoy, S. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Launhardt, R.; Vicente, J. Abreu; Kainulainen, J. [Max-Planck-Institut für Astronomy, Königstuhl 17, D-69117, Heidelberg (Germany); Shirley, Y. [Steward Observatory, 933 North Cherry Avenue, Tucson, AZ 85721 (United States); Stutz, A., E-mail: kawebb@uvic.ca [Departmento de Astronomìa, Facultad Ciencias Físicas y Matemáticas, Universidad de Concepción, Av. Esteban Iturra s/n Barro Universitario, Casilla 160-C, Concepción (Chile)

    2017-11-01

    Density profiles of isolated cores derived from thermal dust continuum emission rely on models of dust properties, such as mass opacity, that are poorly constrained. With complementary measures from near-infrared extinction maps, we can assess the reliability of commonly used dust models. In this work, we compare Herschel -derived maps of the optical depth with equivalent maps derived from CFHT WIRCAM near-infrared observations for three isolated cores: CB 68, L 429, and L 1552. We assess the dust opacities provided from four models: OH1a, OH5a, Orm1, and Orm4. Although the consistency of the models differs between the three sources, the results suggest that the optical properties of dust in the envelopes of the cores are best described by either silicate and bare graphite grains (e.g., Orm1) or carbonaceous grains with some coagulation and either thin or no ice mantles (e.g., OH5a). None of the models, however, individually produced the most consistent optical depth maps for every source. The results suggest that either the dust in the cores is not well-described by any one dust property model, the application of the dust models cannot be extended beyond the very center of the cores, or more complex SED fitting functions are necessary.

  19. Lenticular opacities in proximally exposed A-bomb survivors and their lately significance

    Energy Technology Data Exchange (ETDEWEB)

    Sugimoto, S [Sugimoto Ophthalmological Clinic, Hiroshima (Japan)

    1978-04-01

    Five cases of lenticular opacities in proximally exposed A-bomb survivors (not published yet) were reported with some slides. From these experiment cases, following items were investigated. Significance of A-bomb radiation cataracts: Because cataract is the first manifistation of delayed hazard to a human body caused by A-bomb radiation and can be observed still now, cataract is regarded to be very important for recognizing A-bomb hazard. The manifestation of these findings of cataract is the reason for strong appeals that A-bomb hazard is still existing. Clinical findings of lenticular opacities was searched with reference to the literature. Several findings in experiment cases were described, and the importance of the study about changes of clinical findings was mentioned. It was pointed out that radiation cataract is closely related to the loss of hair in acute atomic radiation hazard. In case of radiation cataract, some difference between right and left eye was sometimes observed. Studies concerning this difference should be further developed in future. The importance of the factors of shielding was pointed out.

  20. Third dredge-up in cluster AGB stars : observational constraints and improved opacity data for models

    International Nuclear Information System (INIS)

    Lederer, M. T.

    2009-01-01

    evolution calculations with our findings. The second part of the thesis deals with a new set of low-temperature mean opacity coefficients. Until recently, the change in chemistry due to the TDU in the cool layers of the star, where molecules are the dominant opacity source, has been neglected in almost all stellar evolution models. I show that already within a certain chemistry regime (i. e. an oxygen-rich or carbon-rich metal mixture) an alteration of the carbon abundance causes, due to the special role of the CO molecule, considerable changes in the Rosseland opacity which has distinct consequences for the stellar structure and evolution. In the stellar evolution models, the most pronounced effect can be expected when the TDU turns the initially oxygen-rich object into a carbon star. The new opacity database contains (beside a variation of the 12 C mass fraction) also tables with a varied abundance of 14 N. After describing the database as well as the tools and the data used for its computation, I point out the implications of the new opacity data for stellar evolution models. (author) [de

  1. Opacity broadening and interpretation of suprathermal CO linewidths: Macroscopic turbulence and tangled molecular clouds

    Science.gov (United States)

    Hacar, A.; Alves, J.; Burkert, A.; Goldsmith, P.

    2016-06-01

    Context. Since their first detection in the interestellar medium, (sub-)millimeter line observations of different CO isotopic variants have routinely been employed to characterize the kinematic properties of the gas in molecular clouds. Many of these lines exhibit broad linewidths that greatly exceed the thermal broadening expected for the low temperatures found within these objects. These observed suprathermal CO linewidths are assumed to originate from unresolved supersonic motions inside clouds. Aims: The lowest rotational J transitions of some of the most abundant CO isotopologues, 12CO and 13CO, are found to present large optical depths. In addition to well-known line saturation effects, these large opacities present a non-negligible contribution to their observed linewidths. Typically overlooked in the literature, in this paper we aim to quantify the impact of these opacity broadening effects on the current interpretation of the CO suprathermal line profiles. Methods: Combining large-scale observations and LTE modeling of the ground J = 1-0 transitions of the main 12CO, 13CO, C18O isotopologues, we have investigated the correlation of the observed linewidths as a function of the line opacity in different regions of the Taurus molecular cloud. Results: Without any additional contributions to the gas velocity field, a large fraction of the apparently supersonic (ℳ ~ 2-3) linewidths measured in both 12CO and 13CO (J = 1-0) lines can be explained by the saturation of their corresponding sonic-like, optically thin C18O counterparts assuming standard isotopic fractionation. Combined with the presence of multiple components detected in some of our C18O spectra, these opacity effects also seem to be responsible for most of the highly supersonic linewidths (ℳ > 8-10) detected in some of the broadest 12CO and 13CO spectra in Taurus. Conclusions: Our results demonstrate that most of the suprathermal 12CO and 13CO linewidths reported in nearby clouds like Taurus

  2. Detection of artificial air space opacities with digital radiography. Ex vivo study on enhanced latitude post-processing

    International Nuclear Information System (INIS)

    Biederer, Juergen; Bolte, H.; Schmidt, T.; Charalambous, N.; Both, M.; Hoffmann, B.; Heller, M.; Kopp, U.; Freitag-Wolf, S.; Van Metter, R.

    2010-01-01

    Purpose: To evaluate in a.-p. digital chest radiograms of an ex vivo system if increased latitude and enhanced image detail contrast (EVP) improve the accuracy of detecting artificial air space opacities in parts of the lung that are superimposed by the diaphragm. Materials and Methods: 19 porcine lungs were inflated inside a chest phantom, prepared with 20-50 ml gelatin-stabilized liquid to generate alveolar air space opacities, and examined with direct radiography (3.0 x 2.5 k detector/125 kVp/4 mAs). 276 a.-p. images with and without EVP of 1.0-3.0 were presented to 6 observers. 8 regions were read for opacities, the reference was defined by CT. Statistics included sensitivity/specificity, interobserver variability, and calculation of Az (area under ROC curve). Results: Behind the diaphragm (opacities in 32/92 regions), the median sensitivity increased from 0.35 without EVP to 0.53 - 0.56 at EVP 1.5 - 3.0 (significant in 5/6 observers). The specificity decreased from 0.96 to 0.90 (significant in 6/6), and the Az value and interobserver correlation increased from 0.66 to 0.74 and 0.39 to 0.48, respectively. Above the diaphragm, the median sensitivity for artificial opacities (136/276 regions) increased from 0.71 to 0.77 - 0.82 with EVP (significant in 4/6 observers). The specificity and Az value decreased from 0.76 to 0.62 and 0.74 to 0.70, respectively, (significant in 3/6). Conclusion: In this ex vivo experiment, EVP improved the diagnostic accuracy for artificial air space opacities in the superimposed parts of the lung (area under the ROC curve). Above the diaphragm, the accuracy was not affected due to a tradeoff in sensitivity/specificity. (orig.)

  3. Propuesta metodológica de evaluación de interfaces de OPACs. INNOPAC versus UNICORN.

    Directory of Open Access Journals (Sweden)

    Rodríguez Bravo, Blanca

    2004-03-01

    Full Text Available The aim of this paper is to present a model of academic OPACs evaluation with the objective of sharing a procedure and some parameters and indicators established. There are two fundamental parameters, the interface searching services and the characteristics of the interface: design, ergonomics and user-friendliness. The present work provides also, the main results of the evaluations of ten OPACs implemented with INNOPAC and UNICORN previously accomplished. Now we will contrast both systems. We consider that universities are institutions that demand OPACs with better services to those of other informative units. The present evaluation has considered the users needs in academic libraries.

    Los propósitos de este trabajo son presentar un modelo de evaluación de OPACs universitarios con el objetivo de compartir un procedimiento y unos parámetros e indicadores establecidos a este fin. Dos son los parámetros fundamentales, las prestaciones de búsqueda de la interfaz y las características de la propia interfaz: diseño, ergonomía y amigabilidad. El presente estudio ofrece, asimismo, los principales resultados de las evaluaciones realizadas en trabajos previos sobre diez OPACs implementados con INNOPAC y UNICORN, que nos permiten ahora contrastar ambos sistemas. Partimos de la consideración de que las universidades son instituciones que por su idiosincrasia exigen OPACs con prestaciones superiores a las de otras unidades informativas. En este sentido, la formalización de los criterios evaluativos ha considerado las necesidades de los usuarios de las bibliotecas universitarias.

  4. Comparison of Usual Interstitial Pneumonia and Nonspecific Interstitial Pneumonia: Quantification of Disease Severity and Discrimination between Two Diseases on HRCT Using a Texture-Based Automated System

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sang Ok; Kim, Dong Soon [University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of); Lee, Young Kyung [East-West Neo Medical Center of Kyung Hee University, Seoul (Korea, Republic of); Lee, Jeong Jin [The Catholic University of Korea, Seoul (Korea, Republic of)

    2011-06-15

    To evaluate the usefulness of an automated system for quantification and discrimination of usual interstitial pneumonia (UIP) and nonspecific interstitial pneumonia (NSIP). An automated system to quantify six regional high-resolution CT (HRCT) patterns: normal, NL; ground-glass opacity, GGO; reticular opacity, RO; honeycombing, HC; emphysema, EMPH; and consolidation, CONS, was developed using texture and shape features. Fifty-four patients with pathologically proven UIP (n = 26) and pathologically proven NSIP (n 28) were included as part of this study. Inter-observer agreement in measuring the extent of each HRCT pattern between the system and two thoracic radiologists were assessed in 26 randomly selected subsets using an interclass correlation coefficient (ICC). A linear regression analysis was used to assess the contribution of each disease pattern to the pulmonary function test parameters. The discriminating capacity of the system between UIP and NSIP was evaluated using a binomial logistic regression. The overall ICC showed acceptable agreement among the system and the two radiologists (r = 0.895 for the abnormal lung volume fraction, 0.706 for the fibrosis fraction, 0.895 for NL, 0.625 for GGO, 0.626 for RO, 0.893 for HC, 0.800 for EMPH, and 0.430 for CONS). The volumes of NL, GGO, RO, and EMPH contribute to forced expiratory volume during one second (FEV1) (r = 0.72, {beta} values, 0.84, 0.34, 0.34 and 0.24, respectively) and forced vital capacity (FVC) (r 0.76, {beta} values, 0.82, 0.28, 0.21 and 0.34, respectively). For diffusing capacity (DLco), the volumes of NL and HC were independent contributors in opposite directions (r = 0.65, {beta} values, 0.64, -0.21, respectively). The automated system can help discriminate between UIP and NSIP with an accuracy of 82%. The automated quantification system of regional HRCT patterns can be useful in the assessment of disease severity and may provide reliable agreement with the radiologists' results. In

  5. Comparison of usual interstitial pneumonia and nonspecific interstitial pneumonia: quantification of disease severity and discrimination between two diseases on HRCT using a texture-based automated system.

    Science.gov (United States)

    Park, Sang Ok; Seo, Joon Beom; Kim, Namkug; Lee, Young Kyung; Lee, Jeongjin; Kim, Dong Soon

    2011-01-01

    To evaluate the usefulness of an automated system for quantification and discrimination of usual interstitial pneumonia (UIP) and nonspecific interstitial pneumonia (NSIP). An automated system to quantify six regional high-resolution CT (HRCT) patterns: normal, NL; ground-glass opacity, GGO; reticular opacity, RO; honeycombing, HC; emphysema, EMPH; and consolidation, CONS, was developed using texture and shape features. Fifty-four patients with pathologically proven UIP (n = 26) and pathologically proven NSIP (n = 28) were included as part of this study. Inter-observer agreement in measuring the extent of each HRCT pattern between the system and two thoracic radiologists were assessed in 26 randomly selected subsets using an interclass correlation coefficient (ICC). A linear regression analysis was used to assess the contribution of each disease pattern to the pulmonary function test parameters. The discriminating capacity of the system between UIP and NSIP was evaluated using a binomial logistic regression. The overall ICC showed acceptable agreement among the system and the two radiologists (r = 0.895 for the abnormal lung volume fraction, 0.706 for the fibrosis fraction, 0.895 for NL, 0.625 for GGO, 0.626 for RO, 0.893 for HC, 0.800 for EMPH, and 0.430 for CONS). The volumes of NL, GGO, RO, and EMPH contribute to forced expiratory volume during one second (FEV₁) (r = 0.72, β values, 0.84, 0.34, 0.34 and 0.24, respectively) and forced vital capacity (FVC) (r = 0.76, β values, 0.82, 0.28, 0.21 and 0.34, respectively). For diffusing capacity (DL(co)), the volumes of NL and HC were independent contributors in opposite directions (r = 0.65, β values, 0.64, -0.21, respectively). The automated system can help discriminate between UIP and NSIP with an accuracy of 82%. The automated quantification system of regional HRCT patterns can be useful in the assessment of disease severity and may provide reliable agreement with the radiologists' results. In addition, this

  6. Model Stellar Atmospheres and Real Stellar Atmospheres and Status of the ATLAS12 Opacity Sampling Program and of New Programs for Rosseland and for Distribution Function Opacity

    Science.gov (United States)

    Kurucz, Robert L.

    1996-01-01

    I discuss errors in theory and in interpreting observations that are produced by the failure to consider resolution in space, time, and energy. I discuss convection in stellar model atmospheres and in stars. Large errors in abundances are possible such as the factor of ten error in the Li abundance for extreme Population II stars. Finally I discuss the variation of microturbulent velocity with depth, effective temperature, gravity, and abundance. These variations must be dealt with in computing models and grids and in any type of photometric calibration. I have also developed a new opacity-sampling version of my model atmosphere program called ATLAS12. It recognizes more than 1000 atomic and molecular species, each in up to 10 isotopic forms. It can treat all ions of the elements up through Zn and the first 5 ions of heavier elements up through Es. The elemental and isotopic abundances are treated as variables with depth. The fluxes predicted by ATLAS12 are not accurate in intermediate or narrow bandpass intervals because the sample size is too small. A special stripped version of the spectrum synthesis program SYNTHE is used to generate the surface flux for the converged model using the line data on CD-ROMs 1 and 15. ATLAS12 can be used to produce improved models for Am and Ap stars. It should be very useful for investigating diffusion effects in atmospheres. It can be used to model exciting stars for H II regions with abundances consistent with those of the H II region. These programs and line files will be distributed on CD-ROMs.

  7. The Next Generation Library Catalog: A Comparative Study of the OPACs of Koha, Evergreen, and Voyager

    Directory of Open Access Journals (Sweden)

    Sharon Q. Yang

    2010-09-01

    Full Text Available Open source has been the center of attention in the library world for the past several years. Koha and Evergreen are the two major open-source integrated library systems (ILSs, and they continue to grow in maturity and popularity. The question remains as to how much we have achieved in open-source development toward the next-generation catalog compared to commercial systems. Little has been written in the library literature to answer this question. This paper intends to answer this question by comparing  the next-generation features of the OPACs of two open-source ILSs (Koha and Evergreen and one proprietary ILS (Voyager’s WebVoyage.

  8. Opacity and Transport Measurements Reveal That Dilute Plasma Models of Sonoluminescence Are Not Valid

    Science.gov (United States)

    Khalid, Shahzad; Kappus, Brian; Weninger, Keith; Putterman, Seth

    2012-03-01

    A strong interaction between a nanosecond laser and a 70 μm radius sonoluminescing plasma is achieved. The overall response of the system results in a factor of 2 increase in temperature as determined by its spectrum. Images of the interaction reveal that light energy is absorbed and trapped in a region smaller than the sonoluminescence emitting region of the bubble for over 100 ns. We interpret this opacity and transport measurement as demonstrating that sonoluminescencing bubbles can be 1000 times more opaque than what follows from the Saha equation of statistical mechanics in the ideal plasma limit. To address this discrepancy, we suggest that the effects of strong Coulomb interactions are an essential component of a first principles theory of sonoluminescence.

  9. 1st oPAC Topical Workshop: Grand Challenges in Accelerator Optimisation

    CERN Document Server

    2013-01-01

    Accelerators are key instruments for fundamental research, health and industry applications. International collaboration is very important for their continued optimisation. To address this oPAC is organising this two-day international workshop on Grand Challenges in Accelerator Optimisation. The workshop will provide an overview of the current state of the art in beam physics, numerical simulations and beam instrumentation and highlight existing limitations. It will discuss research and development being undertaken and ambitions to further improve the performance of existing and future facilities. In addition to invited talks, there will be industry displays and a special seminar covering recent LHC discoveries. All participants will have an opportunity to contribute a poster.

  10. Conceptual design of initial opacity experiments on the national ignition facility

    Energy Technology Data Exchange (ETDEWEB)

    Heeter, R.  F.; Bailey, J.  E.; Craxton, R.  S.; DeVolder, B.  G.; Dodd, E.  S.; Garcia, E.  M.; Huffman, E.  J.; Iglesias, C.  A.; King, J.  A.; Kline, J.  L.; Liedahl, D.  A.; McKenty, P.  W.; Opachich, Y.  P.; Rochau, G.  A.; Ross, P.  W.; Schneider, M.  B.; Sherrill, M.  E.; Wilson, B.  G.; Zhang, R.; Perry, T.  S.

    2017-01-09

    Accurate models of X-ray absorption and re-emission in partly stripped ions are necessary to calculate the structure of stars, the performance of hohlraums for inertial confinement fusion and many other systems in high-energy-density plasma physics. Despite theoretical progress, a persistent discrepancy exists with recent experiments at the Sandia Z facility studying iron in conditions characteristic of the solar radiative–convective transition region. The increased iron opacity measured at Z could help resolve a longstanding issue with the standard solar model, but requires a radical departure for opacity theory. To replicate the Z measurements, an opacity experiment has been designed for the National Facility (NIF). The design uses established techniques scaled to NIF. A laser-heated hohlraum will produce X-ray-heated uniform iron plasmas in local thermodynamic equilibrium (LTE) at temperatures${\\geqslant}150$ eV and electron densities${\\geqslant}7\\times 10^{21}~\\text{cm}^{-3}$. The iron will be probed using continuum X-rays emitted in a${\\sim}200$ ps,${\\sim}200~\\unicode[STIX]{x03BC}\\text{m}$diameter source from a 2 mm diameter polystyrene (CH) capsule implosion. In this design

  11. New constraints on Lyman-α opacity using 92 quasar lines of sight

    Science.gov (United States)

    Bosman, Sarah E. I.; Fan, Xiaohui; Jiang, Linhua; Reed, Sophie; Matsuoka, Yoshiki; Becker, George; Rorai, Albert

    2018-05-01

    The large scatter in Lyman-α opacity at z > 5.3 has been an ongoing mystery, prompting a flurry of numerical models. A uniform ultra-violet background has been ruled out at those redshifts, but it is unclear whether any proposed models produce sufficient inhomogeneities. In this paper we provide an update on the measurement which first highlighted the issue: Lyman-α effective optical depth along high-z quasar lines of sight. We nearly triple on the previous sample size in such a study thanks to the cooperation of the DES-VHS, SHELLQs, and SDSS collaborations as well as new reductions and spectra. We find that a uniform UVB model is ruled out at 5.1 < z < 5.3, as well as higher redshifts, which is perplexing. We provide the first such measurements at z ~ 6. None of the numerical models we confronted to this data could reproduce the observed scatter.

  12. The Interplay of Opacities and Rotation in Promoting the Explosion of Core-Collapse Supernovae

    Science.gov (United States)

    Vartanyan, David; Burrows, Adam; Radice, David

    2018-01-01

    For over five decades, the mechanism of explosion in core-collapse supernovae has been a central unsolved problem in astrophysics, challenging both our computational capabilities and our understanding of relevant physics. Current simulations often produce explosions, but they are at times underenergetic. The neutrino mechanism, wherein a fraction of emitted neutrinos is absorbed in the mantle of the star to reignite the stalled shock, remains the dominant model for reviving explosions in massive stars undergoing core collapse. We present here a diverse suite of 2D axisymmetric simulations produced by FORNAX, a highly parallelizable multidimensional supernova simulation code. We explore the effects of various corrections, including the many-body correction, to neutrino-matter opacities and the possible role of rotation in promoting explosion amongst various core-collapse progenitors.

  13. Lethality Index 2008-2014: Less shootings, same lethality, more opacity

    Directory of Open Access Journals (Sweden)

    Carlos Silva Forné

    2017-11-01

    Full Text Available This article evaluates the use of lethal force by Mexican federal security forces during shootings with presumed members of organized crime from 2008-2014. The authors use official data and press reports on deaths and wounded in shootings to construct indicators such as the number of dead civilians over the number of dead officials from the federal security forces and the number of dead civilians over the number of wounded civilians. In a context where certain factors that contribute to an excessive use of force become more common, the results of the study show a growing use of lethal force. This raises questions over the possible excessive use of lethal force as a normal or systematic practice. The study also shows a growing context of opacity in the information available to evaluate the use of lethal force and the general lack of a legal framework to regulate the use of lethal force in Mexico.

  14. Repeatability of pachymetric mapping using fourier domain optical coherence tomography in corneas with opacities.

    Science.gov (United States)

    Samy El Gendy, Nehal M; Li, Yan; Zhang, Xinbo; Huang, David

    2012-04-01

    To evaluate the repeatability of Fourier domain optical coherence tomography (OCT) pachymetric mapping in patients with corneal opacities and to assess the reliability of Fourier domain OCT with 830 nm wavelength as a pachymetric measurement tool in opaque corneas. A Fourier domain OCT system was used to map the corneal thickness of patients with corneal scars or dystrophy. A retrospective study of a consecutive series was conducted. The repeatability was measured using pooled standard deviation of repeated measurements. A slit-scanning tomography device provided pachymetric mapping for comparison. Seventeen eyes of 12 patients with corneal scars (7 trauma and 3 post infection) or dystrophy (2 Reis-Bucklers and 5 granular dystrophy) were included. The posterior corneal boundary was detectable in all cases. The average corneal thickness measured by OCT was 536 ± 89 μm in central 2 mm area, 553 ± 76 μm in pericentral 2- to 5-mm area, and 508 ± 93 μm for the minimum corneal thickness. The slit-scanning tomography central corneal thickness, 433 ± 111 μm, was significantly lower than OCT readings (mean difference -91.1 ± 33.3 μm, P = 0.002). Repeatability of the OCT measurements was 2.1 μm centrally and 1.2 μm pericentrally. Pachymetric mapping with Fourier domain OCT was highly repeatable. Fourier domain OCT is a reliable pachymetric tool in opaque corneas. In comparison, corneal thickness measured by the slit-scanning tomography is significantly thinner than those measured by the Fourier domain OCT in the presence of corneal opacities.

  15. Lens Opacity and Hydrogen Sulfide in a New Zealand Geothermal Area.

    Science.gov (United States)

    Bates, Michael N; Bailey, Ian L; DiMartino, Robert B; Pope, Karl; Crane, Julian; Garrett, Nick

    2017-04-01

    Hydrogen sulfide (H2S) is a highly toxic gas with well-established, acute irritation effects on the eye. The population of Rotorua, New Zealand, sited on an active geothermal field, has some of the highest ambient H2S exposures in the world. Evidence from ecological studies in Rotorua has suggested that H2S is associated with cataract. The purpose of the present study was, using more detailed exposure characterization, clinical examinations, and anterior eye photography, to more directly investigate this previously reported association. Enrolled were 1637 adults, ages 18 to 65, from a comprehensive Rotorua primary care medical register. Patients underwent a comprehensive ophthalmic examination, including pupillary dilation and lens photography to capture evidence of any nuclear opacity, nuclear color, and cortical and posterior subcapsular opacity. Photographs were scored for all four outcomes on the LOCS III scale with decimalized interpolation between the exemplars. H2S exposure for up to the last 30 years was estimated based on networks of passive samplers set out across Rotorua and knowledge of residential, workplace, and school locations over the 30 years. Data analysis using linear and logistic regression examined associations between the degree of opacification and nuclear color or cataract (defined as a LOCS III score ≥2.0) in relation to H2S exposure. No associations were found between estimated H2S exposures and any of the four ophthalmic outcome measures. Overall, results were generally reassuring. They provided no evidence that H2S exposure at the levels found in Rotorua is associated with cataract. The previously found association between cataract and H2S exposure in the Rotorua population seems likely to be attributable to the limitations of the ecological study design. These results cannot rule out the possibility of an association with cataract at higher levels of H2S exposure.

  16. Effect of resin shades on opacity of ceramic veneers and polymerization efficiency through ceramics.

    Science.gov (United States)

    Öztürk, Elif; Chiang, Yu-Chih; Coşgun, Erdal; Bolay, Şükran; Hickel, Reinhard; Ilie, Nicoleta

    2013-11-01

    The aim of this study was to assess the effect of different resin cement shades on the opacity and color difference of ceramics and to determine the polymerization efficiency of the resin cement at different shades after curing through ceramics. Two different ceramics (IPS e.max Press and IPS Empress(®)CAD, Ivoclar Vivadent) were used for this study. A light-cured veneer luting resin (Variolink Veneer, Ivoclar Vivadent) in four different shades of HV+1, HV+3, LV-1, and LV-3 was used for the colorimetric measurements. The color and spectral reflectance of the ceramics were measured according to the CIELab color scale relative to the standard illuminant D65 on a reflection spectrophotometer (ColorEye7000A, USA). Color differences (ΔE values) and the contrast ratios (CR) of the different groups of samples were calculated. In order to analyse the polymerization efficiency of the resin cements, the micromechanical properties of the resins were measured with an automatic microhardness indenter (Fisherscope H100C, Germany). The results were analysed using one-way ANOVA and Tukey's HSD post hoc tests (SPSS 18.0). The one-way ANOVA test showed that the values of ΔE and CR of the different specimen groups were significantly different (p<0.05). Group 1 (20.7 ± 0.5) (IPS-CAD without resin cement) exhibited the highest and group 10 (14.8 ± 0.5) (e.max:HV+3) exhibited the lowest ΔE value. Significant differences in the micromechanical properties were identified among the tested resin cements in different shades (p<0.05). Resin cement shade is an important factor for the opacity of a restoration. Furthermore, the resin shade affects the micromechanical properties of the underlying resin cement. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Corneal Opacity in Domestic Ducks Experimentally Infected With H5N1 Highly Pathogenic Avian Influenza Virus.

    Science.gov (United States)

    Yamamoto, Y; Nakamura, K; Yamada, M; Mase, M

    2016-01-01

    Domestic ducks can be a key factor in the regional spread of H5N1 highly pathogenic avian influenza (HPAI) virus in Asia. The authors performed experimental infections to examine the relationship between corneal opacity and H5N1 HPAI virus infection in domestic ducks (Anas platyrhyncha var domestica). A total of 99 domestic ducks, including 3 control birds, were used in the study. In experiment 1, when domestic ducks were inoculated intranasally with 2 H5N1 HPAI viruses, corneal opacity appeared more frequently than neurologic signs and mortality. Corneal ulceration and exophthalmos were rare findings. Histopathologic examinations of the eyes of domestic ducks in experiment 2 revealed that corneal opacity was due to the loss of corneal endothelial cells and subsequent keratitis with edema. Influenza viral antigen was detected in corneal endothelial cells and some other ocular cells by immunohistochemistry. Results suggest that corneal opacity is a characteristic and frequent finding in domestic ducks infected with the H5N1 HPAI virus. Confirming this ocular change may improve the detection rate of infected domestic ducks in the field. © The Author(s) 2015.

  18. 40 CFR 60.1450 - How must I monitor opacity for air curtain incinerators that burn 100 percent yard waste?

    Science.gov (United States)

    2010-07-01

    ... curtain incinerators that burn 100 percent yard waste? 60.1450 Section 60.1450 Protection of Environment... Air Curtain Incinerators That Burn 100 Percent Yard Waste § 60.1450 How must I monitor opacity for air curtain incinerators that burn 100 percent yard waste? (a) Use EPA Reference Method 9 in appendix A of...

  19. 40 CFR 60.1925 - How must I monitor opacity for air curtain incinerators that burn 100 percent yard waste?

    Science.gov (United States)

    2010-07-01

    ... curtain incinerators that burn 100 percent yard waste? 60.1925 Section 60.1925 Protection of Environment... or Before August 30, 1999 Model Rule-Air Curtain Incinerators That Burn 100 Percent Yard Waste § 60.1925 How must I monitor opacity for air curtain incinerators that burn 100 percent yard waste? (a) Use...

  20. 40 CFR 62.15380 - How must I monitor opacity for air curtain incinerators that burn 100 percent yard waste?

    Science.gov (United States)

    2010-07-01

    ... curtain incinerators that burn 100 percent yard waste? 62.15380 Section 62.15380 Protection of Environment... Combustion Units Constructed on or Before August 30, 1999 Air Curtain Incinerators That Burn 100 Percent Yard Waste § 62.15380 How must I monitor opacity for air curtain incinerators that burn 100 percent yard...

  1. Opacplot2: Enabling tabulated EoS and opacity compatibility for HEDLP simulations with the FLASH code

    Science.gov (United States)

    Laune, Jordan; Tzeferacos, Petros; Feister, Scott; Fatenejad, Milad; Yurchak, Roman; Flocke, Norbert; Weide, Klaus; Lamb, Donald

    2017-10-01

    Thermodynamic and opacity properties of materials are necessary to accurately simulate laser-driven laboratory experiments. Such data are compiled in tabular format since the thermodynamic range that needs to be covered cannot be described with one single theoretical model. Moreover, tabulated data can be made available prior to runtime, reducing both compute cost and code complexity. This approach is employed by the FLASH code. Equation of state (EoS) and opacity data comes in various formats, matrix-layouts, and file-structures. We discuss recent developments on opacplot2, an open-source Python module that manipulates tabulated EoS and opacity data. We present software that builds upon opacplot2 and enables easy-to-use conversion of different table formats into the IONMIX format, the native tabular input used by FLASH. Our work enables FLASH users to take advantage of a wider range of accurate EoS and opacity tables in simulating HELP experiments at the National Laser User Facilities.

  2. "Garbage" In, "Refuse and Refuse Disposal" Out: Making the Most of the Subject Authority File in OPAC.

    Science.gov (United States)

    Horn, Marguerite E.

    2002-01-01

    Discusses the difference in subject access in OPACs (online public access catalogs) between subject searching (authority, alphabetic, or controlled vocabulary) versus keyword searching (uncontrolled, free text, natural language vocabulary). Compares a query on the term "garbage" in two online catalogs and discusses results. (Author/LRW)

  3. Improvement of chronic corneal opacity in ocular surface disease with prosthetic replacement of the ocular surface ecosystem (PROSE) treatment.

    Science.gov (United States)

    Cressey, Anna; Jacobs, Deborah S; Remington, Crystal; Carrasquillo, Karen G

    2018-06-01

    To demonstrate clearing of chronic corneal opacities and improvement of visual acuity with the use of BostonSight prosthetic replacement of the ocular surface ecosystem (PROSE) treatment in ocular surface disease. We undertook retrospective analysis of the medical records of a series of patients who underwent PROSE treatment from August 2006 to December 2014. Patients were referred for ocular surface disease of various etiologies. Primary inclusion criterion was corneal opacity that improved with PROSE treatment. Patients were excluded if topical steroids or adjuvant therapy used once PROSE treatment was initiated. Underlying disease, prior treatment, clinical presentation, and clinical course were extracted from the medical record. Four patients are included in this series. There were three females and one male; median age at time of treatment initiation was 30 years (range = 0.5-58 years). Median duration of PROSE treatment at time of retrospective analysis was 3.5 years (range = 1-8 years). Two cases had corneal opacification in the context of neurotrophic keratopathy: a unilateral case due to presumed herpes simplex keratitis and a bilateral case due to congenital corneal anesthesia associated with familial dysautonomia. One case had corneal opacity from exposure related to seventh nerve palsy, and one had corneal opacification associated with recurrent surface breakdown, neurotrophic keratopathy, and limbal stem deficiency of uncertain etiology. After consistent wear of prosthetic devices used in PROSE treatment for support of the ocular surface, visual acuity improved and clearing of the opacities was observed, without use of topical steroids or adjuvant therapy. These cases demonstrate clearing of chronic corneal opacity with PROSE treatment for ocular surface disease. This clearing can occur with no adjuvant therapy, suggesting that restoration of ocular surface function and integrity allows for corneal remodeling.

  4. Interstitial lung disease associated with collagen vascular disorders: disease quantification using a computer-aided diagnosis tool

    Energy Technology Data Exchange (ETDEWEB)

    Marten, K.; Engelke, C. [University Hospital of Goettingen, Department of Radiology, Goettingen (Germany); Dicken, V. [MeVis Research GmbH, Bremen (Germany); Kneitz, C. [University Hospital of Wuerzburg, Dept. of Rheumatology and Clinical Immunology, Medizinische Klinik and Poliklinik, Wuerzburg (Germany); Hoehmann, M.; Kenn, W.; Hahn, D. [University Hospital of Wuerzburg, Department of Radiology, Wuerzburg (Germany)

    2009-02-15

    The purpose of this study was to evaluate a computer-aided diagnosis (CAD) tool compared to human observers in quantification of interstitial lung disease (ILD) in patients with collagen-vascular disorders. A total of 52 patients with rheumatoid arthritis (n=24), scleroderma (n=14) and systemic lupus erythematosus (n=14) underwent thin-section CT. Two independent observers assessed the extent of ILD (EoILD), reticulation (EoRet) and ground-glass opacity (EoGGO). CAD assessed EoILD twice. Pulmonary function tests were obtained. Statistical evaluation used 95% limits of agreement and linear regression analysis. CAD correlated well with diffusing capacity (DL{sub CO}) (R=-0.531, P<0.0001) and moderately with forced vital capacity (FVC) (R=-0.483, P=0.0008). There was close correlation between CAD and the readers (EoILD vs. CAD: R=0.716, P<0.0001; EoRet vs. CAD: R=0.69, P<0.0001). Subgroup analysis including patients with minimal EoGGO (<15%) strengthened the correlations between CAD and the readers, readers and PFT, and CAD and PFT. EoILD by readers correlated strongly with DL{sub CO} (R=-0.705, P<0.0001) and moderately with FVC (R=-0.559, P=0.0002). EoRet correlated closely with DL{sub CO} and moderately with FVC (DL{sub CO}: R=-0.663; FVC: R=-0.436; P{<=}0.005). The CAD system is a promising tool for ILD quantification, showing close correlation with human observers and physiologic impairment. (orig.)

  5. Correlation between HRCT findings, pulmonary function tests and bronchoalveolar lavage cytology in interstitial lung disease associated with rheumatoid arthritis

    International Nuclear Information System (INIS)

    Biederer, J.; Muhle, C.; Heller, M.; Reuter, M.; Schnabel, A.; Gross, W.L.

    2004-01-01

    A prospective study correlating high-resolution computed tomography (HRCT), lung function tests (PFT) and bronchoalveolar lavage (BAL) cytology in patients with interstitial lung disease (ILD) associated with rheumatoid arthritis (RA). Fifty-three RA patients with suspected ILD (19 men, 34 women) underwent 71 HRCT (14 of 53 with sequential HRCT, mean follow-up 24.3 months). The HRCT evaluation by two observers on consensus included a semi-quantitative characterisation of lesion pattern and profusion on representative anatomical levels. Fifty-two HRCT were followed by PFT and BAL. Agreement or discordance of HRCT-, PFT- and BAL findings were analysed with Pearson's correlation, κ score and McNemar's test. Tobacco-fume exposure was estimated in pack years. Smoking/non-smoking groups were compared with Student's t test. In 49 of 53 patients, HRCT was suggestive of ILD associated with RA (66 of 71 HRCT). Reticular lesions were found in 40 of 53 patients, in 15 of 40 presenting as mixed pattern with ground-glass opacities (GGO). Pure reticular patterns predominated in patients with long duration of ILD (p>0.01). Pure GGO were not observed. Lesion profusion was highly variable and correlated moderately negative with diffusion capacity (mean 88.2% (SD±20.9%); r=-0.54; p 0.2), but not towards lymphocytosis (κ=0.10; p=0.23; McNemar test p>0.2). Differences in smoking history were not significant (p>0.1). The HRCT appears most appropriate for the detection and follow-up of ILD associated with RA. The PFT and BAL correlate only partially with lesion profusion or grading on HRCT, but they contribute valuable information about dynamic lung function and differential diagnoses (pneumonia, medication side effects). (orig.)

  6. Radiation dose reduction for CT lung cancer screening using ASIR and MBIR: a phantom study.

    Science.gov (United States)

    Mathieu, Kelsey B; Ai, Hua; Fox, Patricia S; Godoy, Myrna Cobos Barco; Munden, Reginald F; de Groot, Patricia M; Pan, Tinsu

    2014-03-06

    The purpose of this study was to reduce the radiation dosage associated with computed tomography (CT) lung cancer screening while maintaining overall diagnostic image quality and definition of ground-glass opacities (GGOs). A lung screening phantom and a multipurpose chest phantom were used to quantitatively assess the performance of two iterative image reconstruction algorithms (adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR)) used in conjunction with reduced tube currents relative to a standard clinical lung cancer screening protocol (51 effective mAs (3.9 mGy) and filtered back-projection (FBP) reconstruction). To further assess the algorithms' performances, qualitative image analysis was conducted (in the form of a reader study) using the multipurpose chest phantom, which was implanted with GGOs of two densities. Our quantitative image analysis indicated that tube current, and thus radiation dose, could be reduced by 40% or 80% from ASIR or MBIR, respectively, compared with conventional FBP, while maintaining similar image noise magnitude and contrast-to-noise ratio. The qualitative portion of our study, which assessed reader preference, yielded similar results, indicating that dose could be reduced by 60% (to 20 effective mAs (1.6 mGy)) with either ASIR or MBIR, while maintaining GGO definition. Additionally, the readers' preferences (as indicated by their ratings) regarding overall image quality were equal or better (for a given dose) when using ASIR or MBIR, compared with FBP. In conclusion, combining ASIR or MBIR with reduced tube current may allow for lower doses while maintaining overall diagnostic image quality, as well as GGO definition, during CT lung cancer screening.

  7. Measurement of nurses' attitudes and knowledge regarding acute care older patients: Psychometrics of the OPACS-US combined with the KOP-Q.

    Science.gov (United States)

    Dikken, Jeroen; Hoogerduijn, Jita G; Lagerwey, Mary D; Shortridge-Baggett, Lillie; Klaassen, Sharon; Schuurmans, Marieke J

    In clinical practice, identifying positive and negative attitudes toward older patients is very important to improve quality of care provided to them. The Older People in Acute Care Survey - United States (OPACS-US) is an instrument measuring hospital nurses attitudes regarding older patients. However, psychometrics have never been assessed. Furthermore, knowledge being related to attitude and behavior should also be measured complementing the OPACS-US. The purpose of this study was to assess structural validity and reliability of the OPACS-US and assess whether the OPACS-US can be complemented with the Knowledge about Older Patients-Quiz (KOP-Q). A multicenter cross sectional design was conducted. Registered nurses (n = 130, mean age 39,9 years; working experience 14,6 years) working in four general hospitals were included in the study. Nurses completed the OPACS-US section A: practice experiences, B: general opinion and the KOP-Q online. Findings demonstrated that the OPACS-US is a valid and reliable survey instrument that measures practice experiences and general opinion. Furthermore, the OPACS-US can be combined with the KOP-Q adding a knowledge construct, and is ready for use within education and/or quality improvement programs in the USA. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. [A Retrospective Study of Mean Computed Tomography Value to Predict 
the Tumor Invasiveness in AAH and Clinical Stage Ia Lung Cancer].

    Science.gov (United States)

    Wu, Hanran; Liu, Changqing; Xu, Meiqing; Xiong, Ran; Xu, Guangwen; Li, Caiwei; Xie, Mingran

    2018-03-20

    Recently, the detectable rate of ground-glass opacity (GGO ) was significantly increased, a appropriate diagnosis before clinic treatment tends to be important for patients with GGO lesions. The aim of this study is to validate the ability of the mean computed tomography (m-CT) value to predict tumor invasiveness, and compared with other measurements such as Max CT value, GGO size, solid size of GGO and C/T ratio (consolid/tumor ratio, C/T) to find out the best measurement to predict tumor invasiveness. A retrospective study was conducted of 129 patients who recieved lobectomy and were pathological confirmed as atypical adenomatous pyperplasia (AAH) or clinical stage Ia lung cance in our center between January 2012 and December 2013. Of those 129 patients, the number of patients of AAH, AIS, AIS and invasive adenocarcinoma were 43, 26, 17 and 43, respectively. We defined AAH and AIS as noninvasive cancer (NC), MIA and invasive adenocarcinoma were categorized as invasive cancer(IC). We used receiver operating characteristic (ROC) curve analysis to compare the ability to predict tumor invasiveness between m-CT value, consolidation/tumor ratio, tumor size and solid size of tumor. Multiple logistic regression analyses were performed to determine the independent variables for prediction of pathologic more invasive lung cancer. 129 patients were enrolled in our study (59 male and 70 female), the patients were a median age of (62.0±8.6) years (range, 44 to 82 years). The two groups were similar in terms of age, sex, differentiation (P>0.05). ROC curve analysis was performed to determine the appropriate cutoff value and area under the cure (AUC). The cutoff value of solid tumor size, tumor size, C/T ratio, m-CT value and Max CT value were 9.4 mm, 15.3 mm, 47.5%, -469.0 HU and -35.0 HU, respectively. The AUC of those variate were 0.89, 0.79, 0.82, 0.90, 0.85, respectively. When compared the clinical and radiologic data between two groups, we found the IC group was strongly

  9. A consistent multigroup model for radiative transfer and its underlying mean opacities

    International Nuclear Information System (INIS)

    Turpault, Rodolphe

    2005-01-01

    In some regimes, such as in plasma physics or in super orbital atmospheric entry of space objects, the effects of radiation are crucial and can tremendously modify the hydrodynamics of the gas. In such cases, it is therefore important to have a good prediction of the radiative variables. However, full transport solutions of these multi-dimensional, time-dependent problems are too expensive to get to be involved in a coupled configuration. It is hence necessary to develop other models for radiation that are cheap, yet accurate enough to give good predictions of the radiative effects. We will herein introduce the multigroup-M1 model and look at its characteristics and in particular try to separate the angular error from the frequential one since these two approximation play very different roles. The angular behaviour of the model will be tested on a case proposed by Su and Olson and used by Olson et al. to compare various moments and (flux-limited) diffusion models. For the frequency behaviour, we use a simplified flame test-case and show the importance of taking good mean opacities

  10. Study of volume recombination and radiation opacity effects in Alcator C-Mod

    International Nuclear Information System (INIS)

    Terry, J.L.; Lipschultz, B.; Pigarov, A.Y.; Boswell, C.; Krasheninnikov, S.I.; LaBombard, B.; Pappas, D.A.

    1998-01-01

    Observations of significant volume recombination within the Alcator C-Mod divertor plasma and in the edge plasma (MARFE) are described. The recombination occurs in regions where T e approx-lt 1 eV and n e approx-gt 1x10 21 m -3 . The determinations of the recombination rates are made by measuring the D 0 Lyman and/or Balmer spectra and by using a collisional radiative model describing the level populations, ionization and recombination of D 0 . In regions of strong recombination the upper levels (n approx-gt 4) populations are close to those determined by Saha-Boltzmann distribution and are independent of the ground state density. Thus the intensities of lines from these levels are related to the recombination rate, and curves determining the number of open-quote recombinations per photon close-quote are calculated. Ly β line emission is shown to be trapped in some cases, meaning that Ly α can be strongly trapped. Since opacity affects the recombination rates, the effects of the trapping of Ly α,β photons on the open-quote recombinations per photon close-quote curves are calculated and considered in the recombination rate determinations. Total recombination rates in the detached divertor plasma and in MARFEs located at the periphery of the main plasma are determined. Recombination can be a significant sink for ions. copyright 1998 American Institute of Physics

  11. Rare cause of multiple nodular opacities at chest x-ray: pulmonary hydatid cyst

    International Nuclear Information System (INIS)

    Inan, K.; Hamcan, S.; Gumus, S.; Turhan, U.; Karaman, B.

    2012-01-01

    Full text: Introduction: Hydatid disease is incidentally common in our country. Objectives and tasks: In this study, unlike the classical radiological appearance of hydatid disease of the lung, MDCT appearance of multiple nodules were demonstrated. Materials and methods: The patient who comes our hospital's Pulmonary Clinic with shortness of breath and with membranes that come from his mouth, referred to our clinic for chest radiography and chest HRCT. Results: In the conventional chest x-ray, multiple nodular opacities in both lungs were common. HRCT was performed with 5 mm and 1 mm thick sections of our patient. In both hemithorax, multiple nodular lesions were found in various sizes and configurations, some of them opened to the bronchus which is the largest one is 2 cm in diameter. Nodule in the left hemithorax inferior lingular segment has calcified wall. Patient's Echinococcus granulosus test was evaluated positive for IgG. Conclusion: Hydatid disease is a parasitic infestation created by Echinococcus granulosus. Although seen most frequently in the liver, often seen in the lungs 10-30%.. 30 to 50% of cases are asymptomatic and incidentally diagnosed radiologically. Although we know that the classic radiologic findings of hydatid cyst, different radiographic views (eg nodular mass) should be considered in rare circumstances

  12. Thermonuclear Bursts with Short Recurrence Times from Neutron Stars Explained by Opacity-driven Convection

    Energy Technology Data Exchange (ETDEWEB)

    Keek, L. [X-ray Astrophysics Laboratory, Astrophysics Science Division, NASA/GSFC, Greenbelt, MD 20771 (United States); Heger, A., E-mail: laurens.keek@nasa.gov [Monash Center for Astrophysics, School of Physics and Astronomy, Monash University, Victoria, 3800 (Australia)

    2017-06-20

    Thermonuclear flashes of hydrogen and helium accreted onto neutron stars produce the frequently observed Type I X-ray bursts. It is the current paradigm that almost all material burns in a burst, after which it takes hours to accumulate fresh fuel for the next burst. In rare cases, however, bursts are observed with recurrence times as short as minutes. We present the first one-dimensional multi-zone simulations that reproduce this phenomenon. Bursts that ignite in a relatively hot neutron star envelope leave a substantial fraction of the fuel unburned at shallow depths. In the wake of the burst, convective mixing events driven by opacity bring this fuel down to the ignition depth on the observed timescale of minutes. There, unburned hydrogen mixes with the metal-rich ashes, igniting to produce a subsequent burst. We find burst pairs and triplets, similar to the observed instances. Our simulations reproduce the observed fraction of bursts with short waiting times of ∼30%, and demonstrate that short recurrence time bursts are typically less bright and of shorter duration.

  13. FERMI LARGE AREA TELESCOPE CONSTRAINTS ON THE GAMMA-RAY OPACITY OF THE UNIVERSE

    International Nuclear Information System (INIS)

    Abdo, A. A.; Ackermann, M.; Ajello, M.; Allafort, A.; Bechtol, K.; Berenji, B.; Blandford, R. D.; Bloom, E. D.; Borgland, A. W.; Bouvier, A.; Atwood, W. B.; Baldini, L.; Bellazzini, R.; Ballet, J.; Barbiellini, G.; Baring, M. G.; Bastieri, D.; Baughman, B. M.; Bhat, P. N.; Bonamente, E.

    2010-01-01

    The extragalactic background light (EBL) includes photons with wavelengths from ultraviolet to infrared, which are effective at attenuating gamma rays with energy above ∼10 GeV during propagation from sources at cosmological distances. This results in a redshift- and energy-dependent attenuation of the γ-ray flux of extragalactic sources such as blazars and gamma-ray bursts (GRBs). The Large Area Telescope on board Fermi detects a sample of γ-ray blazars with redshift up to z ∼ 3, and GRBs with redshift up to z ∼ 4.3. Using photons above 10 GeV collected by Fermi over more than one year of observations for these sources, we investigate the effect of γ-ray flux attenuation by the EBL. We place upper limits on the γ-ray opacity of the universe at various energies and redshifts and compare this with predictions from well-known EBL models. We find that an EBL intensity in the optical-ultraviolet wavelengths as great as predicted by the 'baseline' model of Stecker et al. can be ruled out with high confidence.

  14. Opacity and gradients in aluminum wire array z-pinch implosions on the Z pulsed power facility

    Energy Technology Data Exchange (ETDEWEB)

    Ampleford, D. J., E-mail: damplef@sandia.gov; Hansen, S. B.; Jennings, C. A.; Jones, B.; Coverdale, C. A.; Harvey-Thompson, A. J.; Rochau, G. A.; Dunham, G.; Moore, N. W.; Harding, E. C.; Cuneo, M. E. [Sandia National Laboratories, Albuquerque, New Mexico 87185 (United States); Chong, Y.-K.; Clark, R. W.; Ouart, N.; Thornhill, J. W.; Giuliani, J.; Apruzese, J. P. [Naval Research Laboratory, Washington, DC 20375 (United States)

    2014-03-15

    Aluminum wire array z pinches imploded on the Z generator are an extremely bright source of 1–2 keV radiation, with close to 400 kJ radiated at photon energies >1 keV and more than 50 kJ radiated in a single line (Al Ly-α). Opacity plays a critical role in the dynamics and K-shell radiation efficiency of these pinches. Where significant structure is present in the stagnated pinch this acts to reduce the effective opacity of the system as demonstrated by direct analysis of spectra. Analysis of time-integrated broadband spectra (0.8–25 keV) indicates electron temperatures ranging from a few 100 eV to a few keV are present, indicative of substantial temperature gradients.

  15. APLIKASI ONLINE PUBLIC ACCESS CATALOQUE (OPAC BERBASIS ANDROID SEBAGAI SARANA TEMU KEMBALI INFORMASI DI PERPUSTAKAAN UNIVERSITAS PENDIDIKAN GANESHA

    Directory of Open Access Journals (Sweden)

    Putu Tika Parmawati

    2016-08-01

    Full Text Available Abstrak Penelitian ini bertujuan untuk mengembangkan perangkat lunak aplikasi Online Public Access Cataloque (OPAC berbasis android. Jenis penelitian ini merupakan Research and Development (R & D dengan metode pengembangan menggunakan model prototyping. Pengembangan sistem informasi layanan audio visual berbasis video streaming dengan enam tahap, yaitu : 1 Tahap pengumpulan kebutuhan dan perbaikan, 2 Tahap perancangan desain cepat (desain awal, 3 Tahap membangun prototipe, 4 Tahap evaluasi prototype, 5 Tahap perbaikan prototype, dan 6 Tahap rekayasa produk. Penentuan tingkat kelayakan aplikasi Online Public Access Cataloque (OPAC berbasis android berdasarkan uji validasi ahli bidang teknologi informasi dan uji coba terbatas pada pengguna. Hasil uji coba sebagai berikut : 1 Pengembangan aplikasi Online Public Access Cataloque (OPAC berbasis android sudah sesuai dengan spesifikasi yang telah ditentukan sebagai aplikasi penelusuran informasi koleksi buku teks umum secara online melalui smartphone. 2 Indikator penilaian dari program ini adalah kebenaran atau ketepatan operasional sistem, ketegaran, keterluasan, keterpakaian ulang, efisiensi atau kinerja, portabilitas, integritas, modularitas, keterbacaan mendapat kualifikasi cukup baik, sedangkan verifikasi mendapat kualifikasi baik. 3 Secara umum dari hasil penilaian tersebut aplikasi OPAC berbasis android ini cukup layak untuk digunakan sebagai alternatif pelengkap pemberian layanan penelusuran informasi koleksi buku teks umum di Perpustakaan Undiksha. Kata Kunci: OPAC, android, dan temu kembali informasi Abstract Aim of this study to develop the software of Online Public Access Cataloque (OPAC based on android. Research and Development (R & D design was applied in this study which was developed through prototyping models. The software was constructed through six stages, namely: 1 needs analysis and repairment, 2 rapid design (preliminary design, 3 prototypes building, 4 prototype evaluation, 5

  16. Crescentic and ring-shaped opacities. CT features in two cases of bronchiolitis obliterans organizing pneumonia (BOOP)

    International Nuclear Information System (INIS)

    Voloudaki, A.E.; Bouros, D.E.; Froudarakis, M.E.; Datseris, G.E.; Apostolaki, E.G.; Gourtsoyiannis, N.C.

    1996-01-01

    Two cases of idiopathic bronchilitis obliterans organizing pneumonia (BOOP) with unusual CT findings are presented. On CT both cases exhibited crescentic and ring-shaped opacities, surrounding areas of groundglass attenuation, and associated with a nodular pattern in one patient and airspace consolidations in the second patient. CT-pathologic correlation dislosed that the central areas of groundglass attenuation corresponded to alveolar septal inflammation, in contrast to the denser periphery where granulomatous tissue in peripheral airspaces predominated. In the broad spectrum of CT findings, BOOP can exhibit specific CT features with regard to the crescentic or ring-shaped opacities with a central groundglass attenuation area. Since these features have not been described in any other disease, they might be characteristic features for the diagnosis of BOOP. (orig.)

  17. Significance of lenticular opacity from the view point of the exposure dose of A-bomb radiation

    Energy Technology Data Exchange (ETDEWEB)

    Sugimoto, S [Sugimoto Hospital, Hiroshima (Japan)

    1975-04-01

    Two cases of lenticular opacity were discussed from the view point of exposure dose of A-bomb radiation. Case 1: female, 22 year and 5 months old when she was exposured to A-bomb radiation. The presumed exposure dose was 482.0 rad. Cataract due to A-bomb radiation. Case 2: female, 21 years and 6 months old when she was exposured to A-bomb radiation. The presumed exposure dose was more than 1,000 rad. Cataract due to A-bomb radiation and incipient cataract senilis. It was reported here that there was a marked difference in opacity findings of cataract due to A-bomb radiation in accordance with difference in exposure dose of radiation. It was also presumed from the findings of incipient cataract senilis that with increasing exposure dose, the aging phenomenon was promoted.

  18. Excimer laser-assisted anterior lamellar keratoplasty for keratoconus, corneal problems after laser in situ keratomileusis, and corneal stromal opacities.

    Science.gov (United States)

    Bilgihan, Kamil; Ozdek, Sengül C; Sari, Ayça; Hasanreisoğlu, Berati

    2006-08-01

    To evaluate excimer laser-assisted anterior lamellar keratoplasty to augment thin corneas as in keratoconus ( .05). This technique presents a different modality for the treatment of keratoconus, post-LASIK corneal problems, and other corneal stromal opacities with anterior lamellar keratoplasty. Additional studies with more patients and longer follow-up will help determine the role of this technique as a substitute for penetrating keratoplasty in these patients.

  19. Influence of Projection Operator on Oxygen Line Shapes and its effect on Rosseland-Mean Opacity in Stellar Interiors

    Science.gov (United States)

    Gomez, Thomas; Nagayama, Taisukue; Kilcrease, David; Hansen, Stephanie; Montgomery, Mike; Winget, Don

    2018-01-01

    The Rosseland-Mean opacity (RMO) is an important quantity in determining radiation transport through stars. The solar-convection-zone boundary predicted by the standard solar model disagrees with helioseismology measurements by many sigma; a 14% increase in the RMO would resolve this discrepancy. Experiments at Sandia National Laboratories are now measuring iron opacity at solar-interior conditions, and significant discrepancies are already observed. Highly-ionized oxygen is one of the dominant contributions to the RMO. The strongest line, Lyman alpha, is at the peak of the Rosseland weighting function. The accuracy of line-broadening calculations has been called into question due to various experimental results and comparisons between theory. We have developed an ab-initio calculation to explore different physical effects, our current focus is treating penetrating collisions explicitly. The equation of motion used to calculate line shapes within the relaxation and unified theories includes a projection operator, which performs an average over plasma electron states; this is neglected due to past calculations approximate treatment of penetrations. We now include this projection term explicitly, which results in a significant broadening of spectral lines from highly-charged ions (low-Z elements are not much affected). The additional broadening raises the O Ly-alpha wing opacity by a factor of 5; we examine the consequences of this additional broadening on the Rosseland mean.

  20. Influence of the number of atomic levels on the spectral opacity of low temperature nickel and iron in the spectral range 50-300 eV

    International Nuclear Information System (INIS)

    Busquet, M.; Klapisch, M.; Gilles, D.

    2013-01-01

    Opacity is a fundamental ingredient for the secular evolution of stars. The calculation of the stellar plasma absorption coefficients is complex due to the composition of these plasmas, generally an H /He dominated mixture with a low concentration of partially ionized heavy ions (the iron group). The international collaboration OPAC recently presented extensive comparisons of spectral opacities of iron and nickel for temperatures between 15 and 40 eV and for densities of ∼ 3 mg/cm 3 , relevant to the stellar envelope conditions [1, 2]. The role of Configuration Interaction (CI) and the influence of the number of atomic levels on the opacity using the recently improved version of HULLAC atomic code [3, 4] are illustrated in this article. Comparisons with theoretical predictions already presented in [1] are discussed. (authors)

  1. HRCT-features of Pneumocystis jiroveci pneumonia and their evolution before and after treatment in non-HIV immunocompromised patients

    International Nuclear Information System (INIS)

    Vogel, M.N.; Vatlach, M.; Weissgerber, P.; Goeppert, B.; Claussen, C.D.; Hetzel, J.; Horger, M.

    2012-01-01

    Objective: This study retrospectively analyzes the characteristics and kinetics of pulmonary changes in Pneumocystis jiroveci pneumonia (PJP) before and after treatment as depicted by thin-section-CT in HIV-negative patients. Materials and methods: Serial CT scans of 84 consecutive HIV-negative PJP patients were reviewed retrospectively encompassing a median follow-up of 76 (range, 37–506) days. Along with underlying disease and time span between the onset of symptoms and specific antimicrobial therapy, early and late pulmonary CT-findings were evaluated. Results: Imaging findings at initial diagnosis differed from those in the posttherapeutic setting. In the acute (initial) PJP-phase, most frequent finding was symmetric, apically distributed ground glass opacities (GGO) with peripheral sparing 43% (n = 36). These initial changes resolved up to 1st follow-up-examination in 57% (n = 48), and finally in all except for two patients after a median period of 13 (mean 26, range 1–58) days following application of specific therapy. In 42% (n = 35) architectural distortions occurred, but they resolved after a median period of 27 (mean 60, range 11–302) days. Only in 9 patients, complete resolution could not be documented. Significant correlations of the underlying disease or the time span between the onset of symptoms and specific antibiotic therapy and morphologic kinetic could not be found. Conclusion: Thin-section CT-findings of PJP usually resolve soon after onset of specific therapy. Postinfectious fibrosis rarely occurs following PJP in HIV-negative patients.

  2. The Spectrum of Presentations of Cryptogenic Organizing Pneumonia in High Resolution Computed Tomography

    International Nuclear Information System (INIS)

    Mehrian, Payam; Shahnazi, Makhtoom; Dahaj, Ali Ahmadi; Bizhanzadeh, Sorour; Karimi, Mohammad Ali

    2014-01-01

    Various radiologic patterns of cryptogenic organizing pneumonia (COP) in X-rays have been reported for more than 20 years, and later, in computed tomography scans. The aim of the present study was to describe the spectrum of radiologic findings on high resolution computed tomography (HRCT) scans in patients with COP. HRCT scans of 31 sequential patients (mean age: 54.3±11 years; 55% male) with biopsy-proven COP in a tertiary lung center between 2009 and 2012 were reviewed by two experienced pulmonary radiologists with almost perfect interobserver agreement (kappa=0.83). Chest HRCTs from the lung apex to the base were performed using a 16-slice multi-detector CT scanner. The most common HRCT presentation of COP was ground-glass opacity (GGO) in 83.9% of cases, followed by consolidation in 71%. Both findings were mostly asymmetric bilateral and multifocal. Other common findings were the reverse halo (48.4%), parenchymal bands (54.8%) and subpleural bands (32.3%). Pulmonary nodules were found in about one-third of patients and were frequently smaller than 5 mm in diameter. Both GGOs and consolidations were revealed more often in the lower lobes. The main presentations of COP on HRCT include bilateral GGOs and consolidations in the lower lobes together with the reverse halo sign

  3. Bubble-like appearances are characteristic thin-section CT findings of adenocarcinoma

    International Nuclear Information System (INIS)

    Kojima, Yoko; Saito, Haruhiro; Ito, Hiroyuki

    2008-01-01

    Adenocarcinomas are often diagnosed as old inflammatory lesions which are sometimes overlooked. Some of these adenocarcinomas display characteristic thin-section computed tomography (TS-CT) findings. We reported on these bubble-like appearances (BLA). We studied the BLA characteristics of adenocarcinomas. We reviewed the TS-CT findings of 17 (6 men, 11 women) cases of adenocarcinoma with bubble-like appearances. All 17 patients had undergone surgery between August 2003 and March 2007. We studied correlations between the TS-CT findings, the pathological findings and the clinical characteristics. The average tumor diameter was 35.4 mm. The definition of BLA is; having a irregular shape with straight margins, peripheral ground-glass opacity (GGO), dilated air bronchograms (more than 3), prominent pleural indentation. The pathological characteristics of tumors with BLA were; peripheral bronchioloalveolar cell carcinoma (BAC) patterns, almost total collapse (about 80% of the tumor area), and several ectatic small bronchi. Six cases were initially overlooked, because the TS-CT findings appeared as old inflammation. The average tumor doubling time was 1167 days. After resection, there have been no recurrences. On TS-CT images, BLA type adenocarcinomas appear as irregular in shape and they have a very slow doubling time. These types of lesions require careful attention because they are often diagnosed as old inflammatory scarring. (author)

  4. The Column Density Distribution and Continuum Opacity of the Intergalactic and Circumgalactic Medium at Redshift langzrang = 2.4

    Science.gov (United States)

    Rudie, Gwen C.; Steidel, Charles C.; Shapley, Alice E.; Pettini, Max

    2013-06-01

    We present new high-precision measurements of the opacity of the intergalactic and circumgalactic medium (IGM; CGM) at langzrang = 2.4. Using Voigt profile fits to the full Lyα and Lyβ forests in 15 high-resolution high-S/N spectra of hyperluminous QSOs, we make the first statistically robust measurement of the frequency of absorbers with H I column densities 14 \\lesssim log (N_H\\,\\scriptsize{ I}/ {cm}^{-2}) \\lesssim 17.2. We also present the first measurements of the frequency distribution of H I absorbers in the volume surrounding high-z galaxies (the CGM, 300 pkpc), finding that the incidence of absorbers in the CGM is much higher than in the IGM. In agreement with Rudie et al., we find that there are fractionally more high-N H I absorbers than low-N H I absorbers in the CGM compared to the IGM, leading to a shallower power law fit to the CGM frequency distribution. We use these new measurements to calculate the total opacity of the IGM and CGM to hydrogen-ionizing photons, finding significantly higher opacity than most previous studies, especially from absorbers with log (N_H\\,\\scriptsize{ I}/ {cm}^{-2}) law parameterization of the frequency distribution with a break near N H I ≈1015 cm-2. We compute new estimates of the mean free path (λmfp) to hydrogen-ionizing photons at z em = 2.4, finding λmfp = 147 ± 15 Mpc when considering only IGM opacity. If instead, we consider photons emanating from a high-z star-forming galaxy and account for the local excess opacity due to the surrounding CGM of the galaxy itself, the mean free path is reduced to λmfp = 121 ± 15 Mpc. These λmfp measurements are smaller than recent estimates and should inform future studies of the metagalactic UV background and of ionizing sources at z ≈ 2-3. Based on data obtained at the W. M. Keck Observatory, which is operated as a scientific partnership among the California Institute of Technology, the University of California, and the National Aeronautics and Space

  5. Mid-infrared mapping of Jupiter's temperatures, aerosol opacity and chemical distributions with IRTF/TEXES

    Science.gov (United States)

    Fletcher, Leigh N.; Greathouse, T. K.; Orton, G. S.; Sinclair, J. A.; Giles, R. S.; Irwin, P. G. J.; Encrenaz, T.

    2016-11-01

    Global maps of Jupiter's atmospheric temperatures, gaseous composition and aerosol opacity are derived from a programme of 5-20 μm mid-infrared spectroscopic observations using the Texas Echelon Cross Echelle Spectrograph (TEXES) on NASA's Infrared Telescope Facility (IRTF). Image cubes from December 2014 in eight spectral channels, with spectral resolutions of R ∼2000 - 12 , 000 and spatial resolutions of 2-4° latitude, are inverted to generate 3D maps of tropospheric and stratospheric temperatures, 2D maps of upper tropospheric aerosols, phosphine and ammonia, and 2D maps of stratospheric ethane and acetylene. The results are compared to a re-analysis of Cassini Composite Infrared Spectrometer (CIRS) observations acquired during Cassini's closest approach to Jupiter in December 2000, demonstrating that this new archive of ground-based mapping spectroscopy can match and surpass the quality of previous investigations, and will permit future studies of Jupiter's evolving atmosphere. The visibility of cool zones and warm belts varies from channel to channel, suggesting complex vertical variations from the radiatively-controlled upper troposphere to the convective mid-troposphere. We identify mid-infrared signatures of Jupiter's 5-μm hotspots via simultaneous M, N and Q-band observations, which are interpreted as temperature and ammonia variations in the northern Equatorial Zone and on the edge of the North Equatorial Belt (NEB). Equatorial plumes enriched in NH3 gas are located south-east of NH3-desiccated 'hotspots' on the edge of the NEB. Comparison of the hotspot locations in several channels across the 5-20 μm range indicate that these anomalous regions tilt westward with altitude. Aerosols and PH3 are both enriched at the equator but are not co-located with the NH3 plumes. The equatorial temperature minimum and PH3/aerosol maxima have varied in amplitude over time, possibly as a result of periodic equatorial brightenings and the fresh updrafts of

  6. The role of opacity and transparency in achieving strategic stability in South Asia.

    Energy Technology Data Exchange (ETDEWEB)

    Rajain, Arpit (New Delhi, India); Ashraf, Tariq Mahmud (Islamabad, Pakistan)

    2005-08-01

    According to international relations theory, deterrence can be used as a tool to achieve stability between potentially hostile nations. India and Pakistan's long history of periodic crises raises the question of how they can achieve deterrence stability. 'Transparency' describes the flow of information between parties and plays a key role in establishing a deterrence relationship. This paper studies the balance needed between opacity and transparency in nuclear topics for the maintenance of deterrence stability between India and Pakistan. States with nuclear weapons are postulated to implement transparency in four categories: potential, capability, intent, and resolve. The study applies these categories to the nuclear components of the ongoing India-Pakistan Composite Dialogue Working Group for Peace and Security including CBMs. To focus our efforts, we defined four scenarios to characterize representative strategic/military/political conditions. The scenarios are combinations of these two sets of opposite poles: competition - cooperation; extremism - moderation (to be understood primarily in a religious/nationalistic sense). We describe each scenario in terms of select focal areas (nuclear doctrine, nuclear command and control, nuclear stockpile, nuclear delivery/defensive systems, and conventional force posture). The scenarios help frame the realm of possibilities, and have been described in terms of expected conditions for the focal areas. We then use the conditions in each scenario to prescribe a range of information-sharing actions that the two countries could take to increase stability. We also highlight the information that should not be shared. These actions can be political (e.g., declarations), procedural (e.g., advance notice of certain military activities), or technologically based (e.g., seismic monitoring of the nuclear test moratorium).

  7. Effect of irradiation times on the polymerization depth of contemporary fissure sealants with different opacities

    Directory of Open Access Journals (Sweden)

    Boniek Castillo Dutra Borges

    2011-04-01

    Full Text Available The aim of this study was to evaluate the depth of curing of 10 contemporary blue light-activated dental flowable materials at several opacities, influenced by different irradiation times using FT-IR spectroscopy. Fifty-five specimens (n = 5 with a 5-mm diameter and 1-mm thickness of translucent (Opallis Flow T, yellowed (Master Flow A2; Opallis Flow A2; Natural Flow A2; Fluroshield Yellowed, and opaque materials (Master Flow OA2; Natural Flow O; Opallis Flow OA3.5; Opallis Flow OP; Fluroshield White were obtained at six curing times (10s, 20s, 30s, 40s, 50s, and 60s using a high-intensity LED (Coltolux, Coltène/Whaledent. The degree of conversion (DC (% was obtained using the Nexus 470 FTIR Spectrometer (Nicolet Instruments, USA. The FTIR-ATR spectra for uncured and cured samples were analyzed using a ZnSe crystal. The top and bottom surfaces of the cured specimens were analyzed to obtain the depth of curing. Two-way ANOVA was used to analyze the data. The highest curing depth was obtained by Natural Flow OA2, while the lowest was shown by Master Flow OA2. The shortest curing time generated similar depths of cure in comparison with the most extensive for Opallis Flow A2 and Fluroshield Yellowed. Therefore, depth of curing, influenced by the irradiation time, was dependent on the materials. Using the Natural Flow OA2 opaque sealant and the 10-s curing time for Opallis Flow A2 and Fluroshield Yellowed may represent alternative approaches to sealing tooth fissures.

  8. The opacity of the universe for high and very high energy γ-rays

    International Nuclear Information System (INIS)

    Meyer, Manuel

    2013-08-01

    4σ level. A source intrinsic effect is unlikely to produce such a feature, since the transition to the τ γγ ≥2 regime occurs at different energies for each source. Systematic uncertainties that could mimic the effect are studied but found unlikely as a possible explanation. A similar study is conducted for photons detected with the Fermi-LAT. To this end, the number of expected photons in the optical thick regime is compared to the number of photons observed with the LAT. Above τ γγ ≥2, three photons are associated with AGN with high confidence. Under the assumption of certain EBL models, extrapolating the unattenuated spectrum from low to high energies results in a probability of 1.2 x 10 -4 to observe these photons. However, the probability for detecting the high optical depth photons when all LAT detected AGN with known redshift are considered sensitively depends on the choice of the intrinsic spectral model. The indication for a reduced opacity might be explained by the oscillation of photons into hypothetical axion-like particles (ALPs) in ambient magnetic fields. Such particles propagate unimpeded over cosmological distances, thereby reducing the γ-ray opacity. Photon-ALP conversions are studied in different magnetic field configurations, including intracluster and intergalactic magnetic fields, as well as the field of the Milky Way. Optimistic values of the field strength and coherence length result in lower limits on the photon-ALP coupling, g aγ >or similar 10 -12 GeV -1 . For more realistic magnetic field parameters, couplings above g aγ >or similar 2 x 10 11 GeV -1 are necessary to explain the indication for the reduced opacity. The lower limits are in reach of future dedicated ALP experiments. (orig.)

  9. The opacity of the universe for high and very high energy {gamma}-rays

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, Manuel

    2013-08-15

    }{sub {gamma}{gamma}}<1 to {tau}{sub {gamma}{gamma}}{>=}2 is investigated. The absorption-corrected spectra consistently show an upturn at high optical depths, significant at the 4{sigma} level. A source intrinsic effect is unlikely to produce such a feature, since the transition to the {tau}{sub {gamma}{gamma}}{>=}2 regime occurs at different energies for each source. Systematic uncertainties that could mimic the effect are studied but found unlikely as a possible explanation. A similar study is conducted for photons detected with the Fermi-LAT. To this end, the number of expected photons in the optical thick regime is compared to the number of photons observed with the LAT. Above {tau}{sub {gamma}{gamma}}{>=}2, three photons are associated with AGN with high confidence. Under the assumption of certain EBL models, extrapolating the unattenuated spectrum from low to high energies results in a probability of 1.2 x 10{sup -4} to observe these photons. However, the probability for detecting the high optical depth photons when all LAT detected AGN with known redshift are considered sensitively depends on the choice of the intrinsic spectral model. The indication for a reduced opacity might be explained by the oscillation of photons into hypothetical axion-like particles (ALPs) in ambient magnetic fields. Such particles propagate unimpeded over cosmological distances, thereby reducing the {gamma}-ray opacity. Photon-ALP conversions are studied in different magnetic field configurations, including intracluster and intergalactic magnetic fields, as well as the field of the Milky Way. Optimistic values of the field strength and coherence length result in lower limits on the photon-ALP coupling, g{sub a{gamma}}>or similar 10{sup -12} GeV{sup -1}. For more realistic magnetic field parameters, couplings above g{sub a{gamma}}>or similar 2 x 10{sup 11} GeV{sup -1} are necessary to explain the indication for the reduced opacity. The lower limits are in reach of future dedicated ALP

  10. Pulmonary nodules: Effect of adaptive statistical iterative reconstruction (ASIR) technique on performance of a computer-aided detection (CAD) system—Comparison of performance between different-dose CT scans

    Energy Technology Data Exchange (ETDEWEB)

    Yanagawa, Masahiro, E-mail: m-yanagawa@radiol.med.osaka-u.ac.jp [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Honda, Osamu, E-mail: ohonda@radiol.med.osaka-u.ac.jp [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Kikuyama, Ayano, E-mail: a-kikuyama@radiol.med.osaka-u.ac.jp [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Gyobu, Tomoko, E-mail: t-gyobu@radiol.med.osaka-u.ac.jp [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Sumikawa, Hiromitsu, E-mail: h-sumikawa@radiol.med.osaka-u.ac.jp [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Koyama, Mitsuhiro, E-mail: m-koyama@radiol.med.osaka-u.ac.jp [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Tomiyama, Noriyuki, E-mail: tomiyama@radiol.med.osaka-u.ac.jp [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan)

    2012-10-15

    Purpose: To evaluate the effects of ASIR on CAD system of pulmonary nodules using clinical routine-dose CT and lower-dose CT. Materials and methods: Thirty-five patients (body mass index, 22.17 ± 4.37 kg/m{sup 2}) were scanned by multidetector-row CT with tube currents (clinical routine-dose CT, automatically adjusted mA; lower-dose CT, 10 mA) and X-ray voltage (120 kVp). Each 0.625-mm-thick image was reconstructed at 0%-, 50%-, and 100%-ASIR: 0%-ASIR is reconstructed using only the filtered back-projection algorithm (FBP), while 100%-ASIR is reconstructed using the maximum ASIR and 50%-ASIR implies a blending of 50% FBP and ASIR. CAD output was compared retrospectively with the results of the reference standard which was established using a consensus panel of three radiologists. Data were analyzed using Bonferroni/Dunn's method. Radiation dose was calculated by multiplying dose-length product by conversion coefficient of 0.021. Results: The consensus panel found 265 non-calcified nodules ≤30 mm (ground-glass opacity [GGO], 103; part-solid, 34; and solid, 128). CAD sensitivity was significantly higher at 100%-ASIR [clinical routine-dose CT, 71% (overall), 49% (GGO); lower-dose CT, 52% (overall), 67% (solid)] than at 0%-ASIR [clinical routine-dose CT, 54% (overall), 25% (GGO); lower-dose CT, 36% (overall), 50% (solid)] (p < 0.001). Mean number of false-positive findings per examination was significantly higher at 100%-ASIR (clinical routine-dose CT, 8.5; lower-dose CT, 6.2) than at 0%-ASIR (clinical routine-dose CT, 4.6; lower-dose CT, 3.5; p < 0.001). Effective doses were 10.77 ± 3.41 mSv in clinical routine-dose CT and 2.67 ± 0.17 mSv in lower-dose CT. Conclusion: CAD sensitivity at 100%-ASIR on lower-dose CT is almost equal to that at 0%-ASIR on clinical routine-dose CT. ASIR can increase CAD sensitivity despite increased false-positive findings.

  11. Pulmonary nodules: Effect of adaptive statistical iterative reconstruction (ASIR) technique on performance of a computer-aided detection (CAD) system—Comparison of performance between different-dose CT scans

    International Nuclear Information System (INIS)

    Yanagawa, Masahiro; Honda, Osamu; Kikuyama, Ayano; Gyobu, Tomoko; Sumikawa, Hiromitsu; Koyama, Mitsuhiro; Tomiyama, Noriyuki

    2012-01-01

    Purpose: To evaluate the effects of ASIR on CAD system of pulmonary nodules using clinical routine-dose CT and lower-dose CT. Materials and methods: Thirty-five patients (body mass index, 22.17 ± 4.37 kg/m 2 ) were scanned by multidetector-row CT with tube currents (clinical routine-dose CT, automatically adjusted mA; lower-dose CT, 10 mA) and X-ray voltage (120 kVp). Each 0.625-mm-thick image was reconstructed at 0%-, 50%-, and 100%-ASIR: 0%-ASIR is reconstructed using only the filtered back-projection algorithm (FBP), while 100%-ASIR is reconstructed using the maximum ASIR and 50%-ASIR implies a blending of 50% FBP and ASIR. CAD output was compared retrospectively with the results of the reference standard which was established using a consensus panel of three radiologists. Data were analyzed using Bonferroni/Dunn's method. Radiation dose was calculated by multiplying dose-length product by conversion coefficient of 0.021. Results: The consensus panel found 265 non-calcified nodules ≤30 mm (ground-glass opacity [GGO], 103; part-solid, 34; and solid, 128). CAD sensitivity was significantly higher at 100%-ASIR [clinical routine-dose CT, 71% (overall), 49% (GGO); lower-dose CT, 52% (overall), 67% (solid)] than at 0%-ASIR [clinical routine-dose CT, 54% (overall), 25% (GGO); lower-dose CT, 36% (overall), 50% (solid)] (p < 0.001). Mean number of false-positive findings per examination was significantly higher at 100%-ASIR (clinical routine-dose CT, 8.5; lower-dose CT, 6.2) than at 0%-ASIR (clinical routine-dose CT, 4.6; lower-dose CT, 3.5; p < 0.001). Effective doses were 10.77 ± 3.41 mSv in clinical routine-dose CT and 2.67 ± 0.17 mSv in lower-dose CT. Conclusion: CAD sensitivity at 100%-ASIR on lower-dose CT is almost equal to that at 0%-ASIR on clinical routine-dose CT. ASIR can increase CAD sensitivity despite increased false-positive findings

  12. Distinguishing radiation fibrosis from tumour recurrence after stereotactic ablative radiotherapy (SABR) for lung cancer: A quantitative analysis of CT density changes

    Energy Technology Data Exchange (ETDEWEB)

    Mattonen, Sarah A.; Ward, Aaron D. [Dept. of Medical Biophysics, Univ. of Western Ontario, London, Ontario (Canada); Palma, David A. [Dept. of Radiation Oncology, London Regional Cancer Program, London, Ontario (Canada)], E-mail: david.palma@lhsc.on.ca; Haasbeek, Cornelis J. A.; Senan, Suresh [Dept. of Radiation Oncology, VU Univ. Medical Center, Amsterdam (Netherlands)

    2013-06-15

    Background. For patients treated with stereotactic ablative radiotherapy (SABR) for early-stage non-small cell lung cancer, benign computed tomography (CT) changes due to radiation-induced lung injury (RILI) can be difficult to differentiate from recurrence. We measured the utility of CT image feature analysis in differentiating RILI from recurrence, compared to Response Evaluation Criteria In Solid Tumours (RECIST). Materials and methods. Twenty-two patients with 24 lesions treated with SABR were selected (11 with recurrence, 13 with substantial RILI). On each follow-up CT, consolidative changes and ground glass opacities (GGO) were contoured. For each lesion, contoured regions were analysed for mean and variation in Hounsfi eld units (HU), 3D volume, and RECIST size during follow-up. Results . One hundred and thirtysix CT scans were reviewed, with a median imaging follow-up of 26 months. The 3D volume and RECIST measures of consolidative changes could significantly distinguish recurrence from RILI, but not until 15 months post-SABR; mean volume at 15 months [all values {+-}95% confidence interval (CI)] of 30.1 {+-} 19.3 cm{sup 3} vs. 5.1 {+-} 3.6 cm{sup 3} (p 0.030) and mean RECIST size at 15 months of 4.34 {+-} 1.13 cm vs. 2.63 {+-} 0.84 cm (p =0.028) respectively for recurrence vs. RILI. At nine months post-SABR, patients with recurrence had significantly higher-density consolidative changes (mean at nine months of -96.4 {+-} 32.7 HU vs. -143.2 {+-} 28.4 HU for RILI; p =0.046). They also had increased variability of HU, an image texture metric, measured as the standard deviation (SD) of HU, in the GGO areas (SD at nine months of 210.6 {+-} 14.5 HU vs. 175.1 {+-} 18.7 HU for RILI; p =0.0078). Conclusions. Quantitative changes in mean HU and GGO textural analysis have the potential to distinguish RILI from recurrence as early as nine months post-SABR, compared to 15 months with RECIST and 3D volume. If validated, this approach could allow for earlier detection

  13. Impact of the adaptive statistical iterative reconstruction technique on image quality in ultra-low-dose CT

    International Nuclear Information System (INIS)

    Xu, Yan; He, Wen; Chen, Hui; Hu, Zhihai; Li, Juan; Zhang, Tingting

    2013-01-01

    Aim: To evaluate the relationship between different noise indices (NIs) and radiation dose and to compare the effect of different reconstruction algorithm applications for ultra-low-dose chest computed tomography (CT) on image quality improvement and the accuracy of volumetric measurement of ground-glass opacity (GGO) nodules using a phantom study. Materials and methods: A 11 cm thick transverse phantom section with a chest wall, mediastinum, and 14 artificial GGO nodules with known volumes (919.93 ± 64.05 mm 3 ) was constructed. The phantom was scanned on a Discovery CT 750HD scanner with five different NIs (NIs = 20, 30, 40, 50, and 60). All data were reconstructed with a 0.625 mm section thickness using the filtered back-projection (FBP), 50% adaptive statistical iterative reconstruction (ASiR), and Veo model-base iterative reconstruction algorithms. Image noise was measured in six regions of interest (ROIs). Nodule volumes were measured using a commercial volumetric software package. The image quality and the volume measurement errors were analysed. Results: Image noise increased dramatically from 30.7 HU at NI 20 to 122.4 HU at NI 60, with FBP reconstruction. Conversely, Veo reconstruction effectively controlled the noise increase, with an increase from 9.97 HU at NI 20 to only 15.1 HU at NI 60. Image noise at NI 60 with Veo was even lower (50.8%) than that at NI 20 with FBP. The contrast-to-noise ratio (CNR) of Veo at NI 40 was similar to that of FBP at NI 20. All artificial GGO nodules were successfully identified and measured with an average relative volume measurement error with Veo at NI 60 of 4.24%, comparable to a value of 10.41% with FBP at NI 20. At NI 60, the radiation dose was only one-tenth that at NI 20. Conclusion: The Veo reconstruction algorithms very effectively reduced image noise compared with the conventional FBP reconstructions. Using ultra-low-dose CT scanning and Veo reconstruction, GGOs can be detected and quantified with an acceptable

  14. Early prediction of tumor recurrence based on CT texture changes after stereotactic ablative radiotherapy (SABR) for lung cancer

    International Nuclear Information System (INIS)

    Mattonen, Sarah A.; Palma, David A.; Haasbeek, Cornelis J. A.; Senan, Suresh; Ward, Aaron D.

    2014-01-01

    Purpose: Benign computed tomography (CT) changes due to radiation induced lung injury (RILI) are common following stereotactic ablative radiotherapy (SABR) and can be difficult to differentiate from tumor recurrence. The authors measured the ability of CT image texture analysis, compared to more traditional measures of response, to predict eventual cancer recurrence based on CT images acquired within 5 months of treatment. Methods: A total of 24 lesions from 22 patients treated with SABR were selected for this study: 13 with moderate to severe benign RILI, and 11 with recurrence. Three-dimensional (3D) consolidative and ground-glass opacity (GGO) changes were manually delineated on all follow-up CT scans. Two size measures of the consolidation regions (longest axial diameter and 3D volume) and nine appearance features of the GGO were calculated: 2 first-order features [mean density and standard deviation of density (first-order texture)], and 7 second-order texture features [energy, entropy, correlation, inverse difference moment (IDM), inertia, cluster shade, and cluster prominence]. For comparison, the corresponding response evaluation criteria in solid tumors measures were also taken for the consolidation regions. Prediction accuracy was determined using the area under the receiver operating characteristic curve (AUC) and two-fold cross validation (CV). Results: For this analysis, 46 diagnostic CT scans scheduled for approximately 3 and 6 months post-treatment were binned based on their recorded scan dates into 2–5 month and 5–8 month follow-up time ranges. At 2–5 months post-treatment, first-order texture, energy, and entropy provided AUCs of 0.79–0.81 using a linear classifier. On two-fold CV, first-order texture yielded 73% accuracy versus 76%–77% with the second-order features. The size measures of the consolidative region, longest axial diameter and 3D volume, gave two-fold CV accuracies of 60% and 57%, and AUCs of 0.72 and 0.65, respectively

  15. Nighttime Infrared radiative cooling and opacity inferred by REMS Ground Temperature Sensor Measurements

    Science.gov (United States)

    Martín-Torres, Javier; Paz Zorzano, María; Pla-García, Jorge; Rafkin, Scot; Lepinette, Alain; Sebastián, Eduardo; Gómez-Elvira, Javier; REMS Team

    2013-04-01

    Due to the low density of the Martian atmosphere, the temperature of the surface is controlled primarily by solar heating, and infrared cooling to the atmosphere and space, rather than heat exchange with the atmosphere. In the absence of solar radiation the infrared (IR) cooling, and then the nighttime surface temperatures, are directly controlled by soil termal inertia and atmospheric optical thickness (τ) at infrared wavelengths. Under non-wind conditions, and assuming no processes involving latent heat changes in the surface, for a particular site where the rover stands the main parameter controlling the IR cooling will be τ. The minimal ground temperature values at a fixed position may thus be used to detect local variations in the total dust/aerosols/cloud tickness. The Ground Temperature Sensor (GTS) and Air Temperature Sensor (ATS) in the Rover Environmental Monitoring Station (REMS) on board the Mars Science Laboratory (MSL) Curiosity rover provides hourly ground and air temperature measurements respectively. During the first 100 sols of operation of the rover, within the area of low thermal inertia, the minimal nightime ground temperatures reached values between 180 K and 190 K. For this season the expected frost point temperature is 200 K. Variations of up to 10 K have been observed associated with dust loading at Gale at the onset of the dust season. We will use these measurements together with line-by-line radiative transfer simulations using the Full Transfer By Optimized LINe-by-line (FUTBOLIN) code [Martín-Torres and Mlynczak, 2005] to estimate the IR atmospheric opacity and then dust/cloud coverage over the rover during the course of the MSL mission. Monitoring the dust loading and IR nightime cooling evolution during the dust season will allow for a better understanding of the influence of the atmosphere on the ground temperature and provide ground truth to models and orbiter measurements. References Martín-Torres, F. J. and M. G. Mlynczak

  16. Globular bodies: a primary cause of the opacity in senile and diabetic posterior cortical subcapsular cataracts?

    Science.gov (United States)

    Creighton, M O; Trevithick, J R; Mousa, G Y; Percy, D H; McKinna, A J; Dyson, C; Maisel, H; Bradley, R

    1978-07-01

    We examined 9 cataracts from maturity onset diabetics and 4 senile posterior subcapsular cataracts by scanning electron microscopy, transmission electron microscopy, immunofluorescence for crystallin proteins and actin, histochemical methods and x-ray diffraction. The cataractous regions contained spherical globules up to 20 mu in diameter, often in a fibrous matrix. Some were extracellular Morgagnian globules, apparently formed by blebbing from the cell surface; others appeared to have been formed intracellularly. The area of globular degeneration was usually 300 mu deep, but had deeper fusiform extensions. Morphological changes in the cell cytoplasm varied according to their depth in the cataract. Electron microscopy showed intracellular and extracellular globules, many of them were bounded by lipid bilayer membranes. Immunofluorescent staining showed that all the globules contained gamma-crystallin; some contained alpha- and beta-crystallins and actin. All the globules contained higher concentrations of cysteine or cystine than the surrounding lens tissue but they did not react to stains for carbohydrate or calcium. X-ray diffraction studies showed that crystalline calcium salts were absent. Globules and cavities averaged 45% of the total area in cross section. Assuming an area of cataract to be 300 micron thick and that globules 1 mu in diameter scattered, while 2--20 mu in diameter reflected light, we calculated that light passing through such a thickness would be reduced by 65%. Thus the globules could account for most of the opacity of the cataractous area. Presumably the fibrous degeneration of the cells causes enough light scattering to account for the remainder of the reduction. Cataract patients complain of decreased visual acuity, a golden halo around objects, and difficulties when driving while facing oncoming traffic at night. These probably result from light scattering. In our previous experiments, globular bodies containing gamma-crystallin were

  17. The opacities of 12C-12C reaction and effect of deformed target nucleus on abrasion and absorption cross sections

    International Nuclear Information System (INIS)

    Ramadan, S.; Metawei, Z.

    1995-01-01

    The values of the opacities for 12 C- 12 C reaction are calculated at different incident ion kinetic energy. The exact multiple scattering series for the scattering of two heavy ions which was derived by wilson is used to calculate the abrasion and absorption cross sections of 16 O- 9 Be and 16 O- 16 O collisions, considering a harmonic oscillator matter density for both target and projectiles as spherical nuclei. The effect of including the pauli correlation is considered. The case of deformed target is also investigated. Our results are compared with other calculations as well as with the experimental results

  18. NASCA Report 2: Longitudinal Study of Relationship of Exposure to Space Radiation and Risk of Lens Opacity

    Science.gov (United States)

    Chylack, Leon T., Jr.; Peterson, Leif E.; Feiveson, Alan H.; Tung, William H.; Wear, Mary L.; Marak, Lisa J.; Hardy, Dale S.; Cucinotta, Francis A.

    2011-01-01

    The NASA Study of Cataract in Astronauts (NASCA) was a five-year longitudinal study of the effect of space radiation exposure on the severity/progression of nuclear (N), cortical (C), and posterior subcapsular (PSC) lens opacities. It began in 2003 and was completed in December, 2009. Participants included 171 consenting astronauts who flew at least one mission in space, and comparison subjects consisted of three groups, a) 53 astronauts who had not flown in space, b) 95 military aircrew personnel, and c) 99 non-aircrew, ground-based subjects.

  19. Capilaroscopia periungueal pode sugerir atividade de doença pulmonar na esclerose sistêmica Nailfold capillaroscopy can predict active pulmonary involvement in systemic sclerosis

    Directory of Open Access Journals (Sweden)

    Markus Bredemeier

    2004-02-01

    Full Text Available OBJETIVO: Estudar a associação entre alterações capilaroscópicas e lesões em órgãos-alvo na esclerose sistêmica (ES. MÉTODOS: Noventa e um pacientes com ES foram avaliados através de entrevista, exame físico, capilaroscopia periungueal (CPU, sorologia, provas de função pulmonar, cintilografia de trânsito esofágico, ecocardiografia com Doppler e tomografia computadorizada de alta resolução pulmonar (TCAR. A deleção capilar na CPU foi avaliada usando o escore de deleção vascular de Lee; consideraram-se alterações severas na CPU um escore médio de deleção >1 ou número médio de megacapilares por dedo >1 para fins de análise. Hipertensão arterial pulmonar (HAP foi definida como pressão sistólica na artéria pulmonar >40 mmHg. RESULTADOS: Pacientes com alterações capilaroscópicas severas apresentaram maior prevalência de áreas de opacidades em vidro-fosco (OVF (P=0,016, redução da capacidade difusional pulmonar (P=0,026 e disfunção esofágica (P=0,001. HAP ocorreu somente em pacientes com alterações severas na CPU (P=0,114. Naqueles com duração de doença OBJECTIVE: To evaluate the association of capillaroscopic alterations with end-organ damage in systemic sclerosis (SSc. METHODS: Ninety-one SSc patients were studied through interview, physical examination, nailfold capillary microscopy (NCM, serology, pulmonary function tests, esophageal transit scintigraphy, Doppler echocardiography and pulmonary highresolution computed tomography (HRCT. Capillary loss on NCM was evaluated using the avascular score (AS; patients with mean AS =1 or mean number of megacapillaries per finger =1 were considered to have severe capillaroscopic alterations for analytical purposes. Pulmonary arterial hypertension (PAH was defined as systolic pulmonary arterial pressure =40 mmHg. RESULTS: Patients with severe NCM alterations had greater prevalence of ground-glass opacities (GGO areas (P=0.016, reduced pulmonary diffusing

  20. CON4EI: Bovine Corneal Opacity and Permeability (BCOP) test for hazard identification and labelling of eye irritating chemicals.

    Science.gov (United States)

    Verstraelen, Sandra; Maglennon, Gareth; Hollanders, Karen; Boonen, Francis; Adriaens, Els; Alépée, Nathalie; Drzewiecka, Agnieszka; Gruszka, Katarzyna; Kandarova, Helena; Willoughby, Jamin A; Guest, Robert; Schofield, Jane; Van Rompay, An R

    2017-10-01

    Assessment of ocular irritation potential is an international regulatory requirement in the safety evaluation of industrial and consumer products. None in vitro ocular irritation assays are capable of fully categorizing chemicals as stand-alone. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI consortium assessed the reliability of eight in vitro test methods and computational models as well as established a tiered-testing strategy. One of the selected assays was Bovine Corneal Opacity and Permeability (BCOP). In this project, the same corneas were used for measurement of opacity using the OP-KIT, the Laser Light-Based Opacitometer (LLBO) and for histopathological analysis. The results show that the accuracy of the BCOP OP-KIT in identifying Cat 1 chemicals was 73.8% while the accuracy was 86.3% for No Cat chemicals. BCOP OP-KIT false negative results were often related to an in vivo classification driven by conjunctival effects only. For the BCOP LLBO, the accuracy in identifying Cat 1 chemicals was 74.4% versus 88.8% for No Cat chemicals. The BCOP LLBO seems very promising for the identification of No Cat liquids but less so for the identification of solids. Histopathology as an additional endpoint to the BCOP test method does not reduce the false negative rate substantially for in vivo Cat 1 chemicals. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. High resolution CT findings of pleuropulmonary lnvolvement in systemic lupus erythematosus

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Kun Sik; Kim, Jung Sik; Suh, Soo Jhi; Lee, Sung Moon; Sohn, Seok Ho; Park, Sung Bae; Kim, Hyun Chul [Keimyung University College of Medicine, Deagu (Korea, Republic of)

    1993-09-15

    To evaluate the high resolution computed tomography (HRCT) findings of pleuropulmonary involvement in systemic lupus erythematosus (SLE), we analyzed HRCT findings of 12 patients of clinically confirmed SLE with respiratory symptoms. In four patients, HRCT findings before and after chemotherapy were compared. The common HRCT findings were ground glass opacity (100%), bronchial wall thickening (66%), patch parenchymal opacity (58%), septal or intralobular line thickening (58%), micronodule (58%), central core prominence (41%), small pleural effusion (91%), and pericardial effusion (33%). Follow up HRCT obtained after treatment showed significant improvement of pleural effusion (4/4), pericardial effusion (3/3), pericardial thickening (1/1), patch opacity (2/2), and ground glass opacity (2/4). But bronchial wall thickening (2/2) and micronodule (2/2) were not improved. Although there are no pathognomonic HRCT findings in SLE, bilateral small pleural effusion, ground glass opacity, subpleural patchy opacity, and micronodule are common and suggestive findings in the pleuropulmonary involvement of SLE.

  2. Factors influencing the reading of small irregular opacities in a radiological survey of asbestos miners in South Africa

    International Nuclear Information System (INIS)

    Sluis-Cremer, G.K.; Hessel, P.A.; Hinizdo, E.

    1989-01-01

    A cross-sectional radiological survey of 2 245 men who were employed in South African asbestos mines was conducted in 1976. Since 1976, the lungs of 172 of these men who died have been examined to establish the presence of asbestosis or other pneumoconiosis. The x-ray readings (ILO/UC 1971) were compared with the pathological findings. A high prevalence of false positive readings, particularly for two of the three readers, was found. False negative readings were also very prevalent. Detailed information about asbestos and other mining exposure, smoking habit, age, height, and weight were examined to determine what influence they may have had in inducing false positive findings. Other dust exposure and smoking appeared to be possible factors, whereas age and obesity were probably not. It is suggested that the term small irregular opacities requires more precise definition

  3. OPACITY BROADENING OF {sup 13}CO LINEWIDTHS AND ITS EFFECT ON THE VARIANCE-SONIC MACH NUMBER RELATION

    Energy Technology Data Exchange (ETDEWEB)

    Correia, C.; De Medeiros, J. R. [Departamento de Física Teórica e Experimental, Universidade Federal do Rio Grande do Norte, 59072-970 (Brazil); Burkhart, B.; Lazarian, A. [Astronomy Department, University of Wisconsin, Madison, 475 North Charter Street, WI 53711 (United States); Ossenkopf, V.; Stutzki, J. [Physikalisches Institut der Universität zu Köln, Zülpicher Strasse 77, D-50937 Köln (Germany); Kainulainen, J. [Max-Planck-Institute for Astronomy, Königstuhl 17, D-69117 Heidelberg (Germany); Kowal, G., E-mail: caioftc@dfte.ufrn.br [Instituto de Astronomia, Geofísica e Ciências Atmosféricas, Universidade de São Paulo, 05508-090 (Brazil)

    2014-04-10

    We study how the estimation of the sonic Mach number (M{sub s} ) from {sup 13}CO linewidths relates to the actual three-dimensional sonic Mach number. For this purpose we analyze MHD simulations that include post-processing to take radiative transfer effects into account. As expected, we find very good agreement between the linewidth estimated sonic Mach number and the actual sonic Mach number of the simulations for optically thin tracers. However, we find that opacity broadening causes M{sub s} to be overestimated by a factor of ≈1.16-1.3 when calculated from optically thick {sup 13}CO lines. We also find that there is a dependence on the magnetic field: super-Alfvénic turbulence shows increased line broadening compared with sub-Alfvénic turbulence for all values of optical depth for supersonic turbulence. Our results have implications for the observationally derived sonic Mach number-density standard deviation (σ{sub ρ/(ρ)}) relationship, σ{sub ρ/〈ρ〉}{sup 2}=b{sup 2}M{sub s}{sup 2}, and the related column density standard deviation (σ {sub N/(N)}) sonic Mach number relationship. In particular, we find that the parameter b, as an indicator of solenoidal versus compressive driving, will be underestimated as a result of opacity broadening. We compare the σ {sub N/(N)}-M{sub s} relation derived from synthetic dust extinction maps and {sup 13}CO linewidths with recent observational studies and find that solenoidally driven MHD turbulence simulations have values of σ {sub N/(N)}which are lower than real molecular clouds. This may be due to the influence of self-gravity which should be included in simulations of molecular cloud dynamics.

  4. 40 CFR 60.3067 - How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber...

    Science.gov (United States)

    2010-07-01

    ... curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3067 Section 60.3067... Incineration Units That Commenced Construction On or Before December 9, 2004 Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3067 How must I monitor opacity for...

  5. Morphological analysis and pathological basis of the fine pulmonary reticulation at high-resolution CT

    International Nuclear Information System (INIS)

    Guan Chunshuang; Ma Daqing; Guan Yansheng; Chen Budong; Zhang Yansong

    2010-01-01

    Objective: To study the morphological appearance and pathological basis of the fine pulmonary reticulation at HRCT. Methods: One hundred and seven patients were analyzed about the morphology findings and dynamic changes on pulmonary HRCT. Twenty-four coal worker's pneumoconiosis (CWP) specimens were examined to make comparison between CT and pathology. The data was analyzed by using the Chi-square test. Results: The reticular gap was less than 3 mm in diameter. The morphology of reticulation was round or irregular. Pulmonary parenchyma was seen between the gaps. The reticular wall was smooth or coarse. The thickness was less than 1 mm. One hundred and seven patients had accompanying signs including ground-glass opacity (68.2%, 73 patients), crazy paving (23.4%, 25 patients), interlobular septal thickening (84.1%, 90 patients), emphysema (32.7%, 35 patients), interface sign (58.9%, 63 patients), traction bronchiolectasis (41.1%, 44 patients) and honeycombing (26.2%, 28 patients). The differences of the honeycomb, traction bronchiolectosis, interbobular septal thickening, interface sign and paving were statistically significant between the fibrotic group and pneunonia (P <0.01). Pneumonia showed extensive area of ground-glass opacity (GGO) with fine reticulation. Fine reticculation with both interlobular septal thickening and small nodules were observed more frequently in lmphangitic carcinomatosis. Idiopathic pulmonary fibrosis (IPF) showed fine reticulation among the honeycombing. Connective tissue disease (CTD) showed fine reticulation with rarely honeycombing and it could be partly absorbed. Fine reticulation with emphysema was seen in chronic bronchitis. In the 58 follow-up patients, the fine reticulation increased in 26 patients, decreased or disappeared in 22 patients and showed no change in 10 patients. The major pathological basis of the fine reticulation was intralobular interstitial thickening, including fibrosis hyperplasia, inflammatory cells and tumor

  6. Development of Prototype Micro-Lidar using Narrow Linewidth Semiconductor Lasers for Mars Boundary Layer Wind and Dust Opacity Profiles

    Science.gov (United States)

    Menzies, Robert T.; Cardell, Greg; Chiao, Meng; Esproles, Carlos; Forouhar, Siamak; Hemmati, Hamid; Tratt, David

    1999-01-01

    We have developed a compact Doppler lidar concept which utilizes recent developments in semiconductor diode laser technology in order to be considered suitable for wind and dust opacity profiling in the Mars lower atmosphere from a surface location. The current understanding of the Mars global climate and meteorology is very limited, with only sparse, near-surface data available from the Viking and Mars Pathfinder landers, supplemented by long-range remote sensing of the Martian atmosphere. The in situ measurements from a lander-based Doppler lidar would provide a unique dataset particularly for the boundary layer. The coupling of the radiative properties of the lower atmosphere with the dynamics involves the radiative absorption and scattering effects of the wind-driven dust. Variability in solar irradiance, on diurnal and seasonal time scales, drives vertical mixing and PBL (planetary boundary layer) thickness. The lidar data will also contribute to an understanding of the impact of wind-driven dust on lander and rover operations and lifetime through an improvement in our understanding of Mars climatology. In this paper we discuss the Mars lidar concept, and the development of a laboratory prototype for performance studies, using, local boundary layer and topographic target measurements.

  7. Monte Carlo simulations for thermodynamical properties calculations of plasmas at thermodynamical equilibrium. Applications to opacity and equation of state calculations

    International Nuclear Information System (INIS)

    Gilles, D.

    2005-01-01

    This report is devoted to illustrate the power of a Monte Carlo (MC) simulation code to study the thermodynamical properties of a plasma, composed of classical point particles at thermodynamical equilibrium. Such simulations can help us to manage successfully the challenge of taking into account 'exactly' all classical correlations between particles due to density effects, unlike analytical or semi-analytical approaches, often restricted to low dense plasmas. MC simulations results allow to cover, for laser or astrophysical applications, a wide range of thermodynamical conditions from more dense (and correlated) to less dense ones (where potentials are long ranged type). Therefore Yukawa potentials, with a Thomas-Fermi temperature- and density-dependent screening length, are used to describe the effective ion-ion potentials. In this report we present two MC codes ('PDE' and 'PUCE') and applications performed with these codes in different fields (spectroscopy, opacity, equation of state). Some examples of them are discussed and illustrated at the end of the report. (author)

  8. Opacity alterations of bovine crystalline proteins irradiated with 10 Co in vitro in the presence of sulfonate compounds

    International Nuclear Information System (INIS)

    Bernardes, D.M.L.; Mastro, N.L. del

    1990-01-01

    Sulfhydrilic compounds with a strong basic function separated from the SH group by no more than three C atoms, as amino ethyl iso thiourea (AET) and mercapto ethyl alanine (MEA) are exceptionally effective in competing with free radicals produced by water radiolysis. In a similar way, dimethyl sulfoxide (DMSO) is also effective in the removal of hydroxyl radicals. In the present work, aqueous solutions of crystalline removed surgically from bovine eyes were used. Crystalline were homogenized, the suspension centrifuged and the supernatant dialysed. From the dialysed supernatant a series of solutions was prepared that was 60 Co irradiated with different doses from 5,000 to 25,000 Gy in the presence of 10 mM AET, MEA and DMSO. The degree of opacification was read spectrophotometricaly at 600 nm. The results pointed out a decrease of the increment of opacity produced by the radiation in the presence of those free radical scavengers, showing a radioprotective action of them at the molecular level, that can be measured by this method that mimics the cataract formation in eye lens. (author)

  9. On the necessity of composition-dependent low-temperature opacity in models of metal-poor asymptotic giant branch stars

    Energy Technology Data Exchange (ETDEWEB)

    Constantino, Thomas; Campbell, Simon; Lattanzio, John [Monash Centre for Astrophysics, School of Mathematical Sciences, Monash University, Victoria 3800 (Australia); Gil-Pons, Pilar, E-mail: thomas.constantino@monash.edu [Department of Applied Physics, Polytechnic University of Catalonia, 08860 Barcelona (Spain)

    2014-03-20

    The vital importance of composition-dependent low-temperature opacity in low-mass (M ≤ 3 M {sub ☉}) asymptotic giant branch (AGB) stellar models of metallicity Z ≥ 0.001 has recently been demonstrated. Its significance to more metal-poor, intermediate-mass (M ≥ 2.5 M {sub ☉}) models has yet to be investigated. We show that its inclusion in lower-metallicity models ([Fe/H] ≤–2) is essential and that there exists no threshold metallicity below which composition-dependent molecular opacity may be neglected. We find it to be crucial in all intermediate-mass models investigated ([Fe/H] ≤–2 and 2.5 ≤ M/M {sub ☉} ≤ 5), because of the evolution of the surface chemistry, including the orders of magnitude increase in the abundance of molecule-forming species. Its effect on these models mirrors that previously reported for higher-metallicity models—increase in radius, decrease in T {sub eff}, faster mass loss, shorter thermally pulsing AGB lifetime, reduced enrichment in third dredge-up products (by a factor of 3-10), and an increase in the mass limit for hot bottom burning. We show that the evolution of low-metallicity models with composition-dependent low-temperature opacity is relatively independent of initial metal abundance because its contribution to the opacity is far outweighed by changes resulting from dredge-up. Our results imply a significant reduction in the expected number of nitrogen-enhanced metal-poor stars, which may help explain their observed paucity. We note that these findings are partially a product of the macrophysics adopted in our models, in particular, the Vassiliadis and Wood mass loss rate which is strongly dependent on radius.

  10. Effects of Silicone Hydrogel Contact Lens Application on Corneal High-order Aberration and Visual Guality in Patients with Corneal Opacities

    Directory of Open Access Journals (Sweden)

    Sevda Aydın Kurna

    2012-03-01

    Full Text Available Pur po se: Evaluation of the corneal high-order aberrations and visual quality changes after application of silicone hydrogel contact lenses in patients with corneal opacities due to various etiologies. Ma te ri al and Met hod: Fifteen eyes of 13 patients with corneal opacities were included in the study. During the ophthalmologic examination before and after contact lens application, visual acuity was measured with Snellen acuity chart and contrast sensitivity - with Bailey-Lowie Charts in letters. Aberrations were measured with corneal aberrometer (NIDEK Magellan Mapper under a naturally dilated pupil. Spherical aberration, coma, trefoil, irregular astigmatism and total high-order root mean square (RMS values were recorded. Measurements were repeated with balafilcon A lenses (PureVision 2 HD, B&L on all patients. Re sults: Patient age varied between 23 and 50 years. Two eyes had subepithelial infiltrates due to adenoviral keratitis, 1 had nebulae due to previous infections or trauma, and 2 had Salzmann’s nodular degeneration. We observed a mean increase of 1 line in visual acuity and 5 letters in contrast sensitivity with contact lenses versus glasses in the patients. Mean RMS values of spherical aberration, irregular astigmatism and total high-order aberrations decreased significantly with contact lenses. Dis cus si on: Silicone hydrogel soft contact lenses may improve visual quality by decreasing the corneal aberrations in patients with corneal opacities. (Turk J Ophthalmol 2012; 42: 97-102

  11. Effect of tobacco smoking on the presence of asbestosis at postmortem and on the reading of irregular opacities on roentgenograms in asbestos-exposed workers

    International Nuclear Information System (INIS)

    Hnizdo, E.; Sluis-Cremer, G.K.

    1988-01-01

    A statistically significant association between cigarette smoking and radiologic readings of irregular opacities was observed in a case-control study of 430 South African asbestos miners (OR = 3.03; 95% confidence interval, 1.50; 6.11). In another case-control study of 487 dead South African asbestos miners, no positive association between smoking and autopsy findings for asbestosis was observed (OR = 0.50; 95% confidence interval, 0.20; 1.29). The association between greater than slight asbestosis (moderate and marked) and smoking (yes/no) was not significant (Fisher's exact test, p = 0.44), and the adjusted odds ratio was 1.25 with 95% confidence interval (0.20; 7.78). In addition, the certification in life for asbestosis, based on chest roentgenogram readings for irregular opacities, was also found to have a tendency to be related to smoking. Thus, the findings of these studies do not support the hypothesis that smoking is associated with the presence of asbestosis at autopsy or that smoking and asbestos dust act synergistically in producing asbestosis at autopsy. But the findings of this and other studies suggest that smoking does produce some change in the lung structure that can be visible on the roentgenogram and can be wrongly interpreted as irregular opacities caused by asbestosis

  12. The Impact of Lens Opacity on SD-OCT Retinal Nerve Fiber Layer and Bruch's Membrane Opening Measurements Using the Anatomical Positioning System (APS).

    Science.gov (United States)

    Mauschitz, Matthias M; Roth, Felix; Holz, Frank G; Breteler, Monique M B; Finger, Robert P

    2017-05-01

    To evaluate the impact of lens opacity on retinal nerve fiber layer thickness (RNFLT) and Bruch's membrane opening (BMO) measurements. Fifty-nine randomly selected patients without any other relevant ocular pathology undergoing elective routine cataract surgery in two specialized eye clinics were enrolled. RNFLT, BMO area, and BMO minimum rim width (BMO-MRW) were assessed with the Heidelberg Engineering Spectralis OCT using the anatomical positioning system (APS) prior to and 1 day after cataract surgery using a ring scan at different eccentricities of the disc (3.5, 4.1 and 4.7 mm). Lens opacity was quantified using densitometry based on Scheimpflug images (Oculus Pentacam AXL). RNFLT, BMO area, and BMO-MRW were virtually identical before and following removal of the cataractous lens. This held when assessed overall, within the six sectors for the 3.5-mm scan, or at any other eccentricity. Baseline RNFLT was not associated with lens opacity. Using the APS, RNFLT remained unchanged following cataract surgery, contrary to results reported by previous studies. Our results imply that the APS may have contributed to more precise spectral-domain optical coherence measurements, minimizing the influence of cataract on RNFLT and BMO assessments in our cohort.

  13. H‑ Opacity and Water Dissociation in the Dayside Atmosphere of the Very Hot Gas Giant WASP-18b

    Science.gov (United States)

    Arcangeli, Jacob; Désert, Jean-Michel; Line, Michael R.; Bean, Jacob L.; Parmentier, Vivien; Stevenson, Kevin B.; Kreidberg, Laura; Fortney, Jonathan J.; Mansfield, Megan; Showman, Adam P.

    2018-03-01

    We present one of the most precise emission spectra of an exoplanet observed so far. We combine five secondary eclipses of the hot Jupiter WASP-18b (T day ∼ 2900 K) that we secured between 1.1 and 1.7 μm with the Wide Field Camera 3 instrument on board the Hubble Space Telescope. Our extracted spectrum (S/N = 50, R ∼ 40) does not exhibit clearly identifiable molecular features but is poorly matched by a blackbody spectrum. We complement this data with previously published Spitzer/Infrared Array Camera observations of this target and interpret the combined spectrum by computing a grid of self-consistent, 1D forward models, varying the composition and energy budget. At these high temperatures, we find there are important contributions to the overall opacity from H‑ ions, as well as the removal of major molecules by thermal dissociation (including water), and thermal ionization of metals. These effects were omitted in previous spectral retrievals for very hot gas giants, and we argue that they must be included to properly interpret the spectra of these objects. We infer a new metallicity and C/O ratio for WASP-18b, and find them well constrained to be solar ([M/H] = ‑0.01 ± 0.35, C/O < 0.85 at 3σ confidence level), unlike previous work but in line with expectations for giant planets. The best-fitting self-consistent temperature–pressure profiles are inverted, resulting in an emission feature at 4.5 μm seen in the Spitzer photometry. These results further strengthen the evidence that the family of very hot gas giant exoplanets commonly exhibit thermal inversions.

  14. High resolution computed tomographic features of pulmonary alveolar microlithiasis

    International Nuclear Information System (INIS)

    Deniz, Omer; Ors, Fatih; Tozkoparan, Ergun; Ozcan, Ayhan; Gumus, Seyfettin; Bozlar, Ugur; Bilgic, Hayati; Ekiz, Kudret; Demirci, Necmettin

    2005-01-01

    Background: Pulmonary alveolar microlithiasis (PAM) is a rare, chronic lung disease with unknown etiology and with a nonuniform clinical course. Nonuniformity of clinical course might be related to the degree of pulmonary parenchymal alterations, which can be revealed with high resolution computed tomography (HRCT). However, HRCT findings of PAM were not fully described in the current literature. Aim: The aim of this study was to interpret and to contribute to describe HRCT findings of PAM and to investigate a correlation between profusion of micro nodules (MN) and pulmonary parenchymal alterations in patients with PAM. Material and methods: Ten male patients with PAM (mean age: 22 ± 3.2) were included into the study. HRCT images were assessed for patterns, distribution, and profusion of pulmonary abnormalities. Dividing the lungs into three zones, profusion of abnormalities was assessed. A profusion score (1-4) was given and the scores of each zone were then summed to obtain a global profusion score for HRCT ranging from 0 to 12. Also a parenchymal alteration score (PAS) was defined with respect to profusion of abnormalities. Chest X-rays were also scored. Results: All of ten patients with PAM had findings of interstitial lung disease in varying degrees on their HRCTs. HRCT findings of patients with PAM were as following: MN, parenchymal bands (PB), ground glass opacity (GGO) and, sub pleural interstitial thickening (SPIT) in 10 patients; interlobular septal thickening (ILST), in 9 patients; paraseptal emphysema (PSA) in 8 patients; centrilobular emphysema (CLA) in 7 patients; bronchiectasis (BE), confluent micro nodules (CMN) in 6 patients; peri bronchovascular interstitial thickening (PBIT) in 5 patients; panacinar emphysema (PANAA) in 3 patients; pleural calcification (PC) in 2 patients. A significant correlation between MN scores and PAS (r = 0.68, p = 0.031, MN scores and GGO scores (r = 0.69, p = 0.027) and, MN scores and CLA scores (r = 0.67, p = 0

  15. MERS-CoV: Middle East respiratory syndrome corona virus: Can radiology be of help? Initial single center experience

    Directory of Open Access Journals (Sweden)

    Ahmed Hamimi

    2016-03-01

    Conclusions: MERS CoV virus may have a specific pattern in chest X-ray and CT developing a single or multiple opacities progressing into a widespread multifocal bilateral patches of ground glass opacities or confluent consolidation resembling organizing pneumonia.

  16. 64 multidetector CT findings of influenza A (H1N1) virus in patients with hematologic malignancies

    International Nuclear Information System (INIS)

    El-Badrawy, Adel; Zeidan, Amany; Ebrahim, Mohamed A.

    2012-01-01

    Background. The pandemic of swine-origin H1N1 influenza that began in early 2009 has provided evidence that radiology can assist in the early diagnosis of severe cases. Immunocompromised patients are at increased risk for morbidity and mortality. MDCT is superior to radiography in showing the distribution of the disease. Purpose. To review the 64 multidetector CT thoracic findings of novel swine-origin influenza A (H1N1) virus in patients with hematologic malignancies. Material and Methods. This study included 12 patients (3 women, 9 men; mean age, 32.2 years). All patients proved to be infected with influenza A (H1N1) virus. The hematologic malignancies were acute myeloid leukemia (n = 8), chronic lymphocytic leukemia (n = 2), multiple myeloma (n = 1), and myelodysplastic syndrome (n = 1). All the patients underwent CT scanning using a 64 multidetector CT scanner. Chest CT scans were reviewed for ground-glass opacities (GGOs), consolidation, airway thickening/dilatation, nodules, mediastinal lymphadenopathy, and pleural effusion. Results. More than one CT finding was detected in every patient. Pulmonary affection was bilateral, more on the left side. The affections were mainly peribronchial. Airway wall thickening and dilatation were detected in all 12 patients, GGO in 9/12 patients, nodules in 6/12 patients, consolidation in 6/12 patients, hilar lymphadenopathy in 3/12 patients, and pleural effusion in 2/12 patients. Conclusion. Acute myeloid leukemia is the most common hematologic malignancy affected by influenza A (H1N1) virus. The left lung is affected more than the right one. The most common multidetector CT findings are unilateral or bilateral airway thickening and dilatation. Multidetector CT can be used for early and accurate assessment of pulmonary affection with influenza A H1N1 virus infection

  17. Large scale validation of the M5L lung CAD on heterogeneous CT datasets

    Energy Technology Data Exchange (ETDEWEB)

    Lopez Torres, E., E-mail: Ernesto.Lopez.Torres@cern.ch, E-mail: cerello@to.infn.it [CEADEN, Havana 11300, Cuba and INFN, Sezione di Torino, Torino 10125 (Italy); Fiorina, E.; Pennazio, F.; Peroni, C. [Department of Physics, University of Torino, Torino 10125, Italy and INFN, Sezione di Torino, Torino 10125 (Italy); Saletta, M.; Cerello, P., E-mail: Ernesto.Lopez.Torres@cern.ch, E-mail: cerello@to.infn.it [INFN, Sezione di Torino, Torino 10125 (Italy); Camarlinghi, N.; Fantacci, M. E. [Department of Physics, University of Pisa, Pisa 56127, Italy and INFN, Sezione di Pisa, Pisa 56127 (Italy)

    2015-04-15

    Purpose: M5L, a fully automated computer-aided detection (CAD) system for the detection and segmentation of lung nodules in thoracic computed tomography (CT), is presented and validated on several image datasets. Methods: M5L is the combination of two independent subsystems, based on the Channeler Ant Model as a segmentation tool [lung channeler ant model (lungCAM)] and on the voxel-based neural approach. The lungCAM was upgraded with a scan equalization module and a new procedure to recover the nodules connected to other lung structures; its classification module, which makes use of a feed-forward neural network, is based of a small number of features (13), so as to minimize the risk of lacking generalization, which could be possible given the large difference between the size of the training and testing datasets, which contain 94 and 1019 CTs, respectively. The lungCAM (standalone) and M5L (combined) performance was extensively tested on 1043 CT scans from three independent datasets, including a detailed analysis of the full Lung Image Database Consortium/Image Database Resource Initiative database, which is not yet found in literature. Results: The lungCAM and M5L performance is consistent across the databases, with a sensitivity of about 70% and 80%, respectively, at eight false positive findings per scan, despite the variable annotation criteria and acquisition and reconstruction conditions. A reduced sensitivity is found for subtle nodules and ground glass opacities (GGO) structures. A comparison with other CAD systems is also presented. Conclusions: The M5L performance on a large and heterogeneous dataset is stable and satisfactory, although the development of a dedicated module for GGOs detection could further improve it, as well as an iterative optimization of the training procedure. The main aim of the present study was accomplished: M5L results do not deteriorate when increasing the dataset size, making it a candidate for supporting radiologists on large

  18. 64 multidetector CT findings of influenza A (H1N1) virus in patients with hematologic malignancies

    Energy Technology Data Exchange (ETDEWEB)

    El-Badrawy, Adel [Dept. of Radiology, Mansoura Faculty of Medicine, Mansoura (Egypt)], E-mail: adelelbadrawy@hotmail.com; Zeidan, Amany [Dept. of Thoracic Medicine, Mansoura Faculty of Medicine, Mansoura (Egypt); Ebrahim, Mohamed A. [Dept. of Medical Oncology, Mansoura Faculty of Medicine, Mansoura (Egypt)

    2012-07-15

    Background. The pandemic of swine-origin H1N1 influenza that began in early 2009 has provided evidence that radiology can assist in the early diagnosis of severe cases. Immunocompromised patients are at increased risk for morbidity and mortality. MDCT is superior to radiography in showing the distribution of the disease. Purpose. To review the 64 multidetector CT thoracic findings of novel swine-origin influenza A (H1N1) virus in patients with hematologic malignancies. Material and Methods. This study included 12 patients (3 women, 9 men; mean age, 32.2 years). All patients proved to be infected with influenza A (H1N1) virus. The hematologic malignancies were acute myeloid leukemia (n = 8), chronic lymphocytic leukemia (n = 2), multiple myeloma (n = 1), and myelodysplastic syndrome (n = 1). All the patients underwent CT scanning using a 64 multidetector CT scanner. Chest CT scans were reviewed for ground-glass opacities (GGOs), consolidation, airway thickening/dilatation, nodules, mediastinal lymphadenopathy, and pleural effusion. Results. More than one CT finding was detected in every patient. Pulmonary affection was bilateral, more on the left side. The affections were mainly peribronchial. Airway wall thickening and dilatation were detected in all 12 patients, GGO in 9/12 patients, nodules in 6/12 patients, consolidation in 6/12 patients, hilar lymphadenopathy in 3/12 patients, and pleural effusion in 2/12 patients. Conclusion. Acute myeloid leukemia is the most common hematologic malignancy affected by influenza A (H1N1) virus. The left lung is affected more than the right one. The most common multidetector CT findings are unilateral or bilateral airway thickening and dilatation. Multidetector CT can be used for early and accurate assessment of pulmonary affection with influenza A H1N1 virus infection.

  19. Universe opacity and EBL

    Czech Academy of Sciences Publication Activity Database

    Vavryčuk, Václav

    2017-01-01

    Roč. 465, č. 2 (2017), s. 1532-1542 ISSN 0035-8711 Institutional support: RVO:67985530 Keywords : cosmic background radiation * dust, extinction * early Universe * galaxies: high redshift * galaxies: ISM * intergalactic medium Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics OBOR OECD: Astronomy (including astrophysics,space science) Impact factor: 4.961, year: 2016

  20. NASA study of cataract in astronauts (NASCA). Report 1: Cross-sectional study of the relationship of exposure to space radiation and risk of lens opacity.

    Science.gov (United States)

    Chylack, Leo T; Peterson, Leif E; Feiveson, Alan H; Wear, Mary L; Manuel, F Keith; Tung, William H; Hardy, Dale S; Marak, Lisa J; Cucinotta, Francis A

    2009-07-01

    The NASA Study of Cataract in Astronauts (NASCA) is a 5-year longitudinal study of the effect of space radiation exposure on the severity/progression of nuclear, cortical and posterior subcapsular (PSC) lens opacities. Here we report on baseline data that will be used over the course of the longitudinal study. Participants include 171 consenting astronauts who flew at least one mission in space and a comparison group made up of three components: (a) 53 astronauts who had not flown in space, (b) 95 military aircrew personnel, and (c) 99 non-aircrew ground-based comparison subjects. Continuous measures of nuclear, cortical and PSC lens opacities were derived from Nidek EAS 1000 digitized images. Age, demographics, general health, nutritional intake and solar ocular exposure were measured at baseline. Astronauts who flew at least one mission were matched to comparison subjects using propensity scores based on demographic characteristics and medical history stratified by gender and smoking (ever/never). The cross-sectional data for matched subjects were analyzed by fitting customized non-normal regression models to examine the effect of space radiation on each measure of opacity. The variability and median of cortical cataracts were significantly higher for exposed astronauts than for nonexposed astronauts and comparison subjects with similar ages (P=0.015). Galactic cosmic space radiation (GCR) may be linked to increased PSC area (P=0.056) and the number of PSC centers (P=0.095). Within the astronaut group, PSC size was greater in subjects with higher space radiation doses (P=0.016). No association was found between space radiation and nuclear cataracts. Cross-sectional data analysis revealed a small deleterious effect of space radiation for cortical cataracts and possibly for PSC cataracts. These results suggest increased cataract risks at smaller radiation doses than have been reported previously.

  1. NextLib : un sistema de software basado en ontologías para la consulta automática de OPACs desde sedes web especializadas

    OpenAIRE

    Felip Vidal, Lledó; Orduña-Malea, Enrique

    2008-01-01

    Las extensiones para navegadores web (Add-ons) están ampliando las funcionalidades de éstos. Entre ellas cabe destacar la reciente aparición de LibX, herramienta que permite la interacción entre el OPAC de una biblioteca y la Web. Se estudian las limitaciones de esta herramienta en cuanto a detección automática de datos y automatización de tareas para proponer un sistema (NextLib) que, mediante la combinación de diferentes aplicaciones, permita superarlas. Este sistema estaría for...

  2. Follow-up Aspects of Influenza A (H1N1) Virus-Associated Pneumonia: the Role of High-Resolution Computed Tomography in the Evaluation of the Recovery Phase

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson; Zanetti, Gla ucia; Mano, Cla udia Mauro; Hochhegger, Bruno [Federal University College of Medicine, Rio de Janeiro, (Brazil); Irion, Klaus Loureiro [Broadgreen University Hospital NHS Trust, Liverpool (United Kingdom)

    2010-10-15

    The first patient showed ill-defined ground-glass opacity nodules and patchy areas of ground-glass attenuation. The second, with secondary bacterial pneumonia, showed bilateral areas of lobar consolidation and ground-glass opacities. The predominant HRCT findings reported bilateral, peripheral, ground-glass opacities and/or bilateral areas of consolidation. The patients who presented with consolidations had a more severe clinical course. Limited data are available, however, on the tomographic or pathological aspects observed during the recovery phase after H1N1 infection. During the treatment and recovery phases, persistent opacities on radiographs may not be informative enough to distinguish disease progression from healing. HRCT may play a role in the detection and characterization of the disease, in monitoring the disease progress and response to treatment, as well as in the identification of complications. In conclusion, although pulmonary opacities secondary to H1N1 infection usually regress during convalescence, the consolidations may occasionally progress to linear opacities (parenchymal bands). These linear opacities probably represent organizing pneumonia.

  3. Reprint of "CON4EI: Bovine Corneal Opacity and Permeability (BCOP) test for hazard identification and labelling of eye irritating chemicals".

    Science.gov (United States)

    Verstraelen, Sandra; Maglennon, Gareth; Hollanders, Karen; Boonen, Francis; Adriaens, Els; Alépée, Nathalie; Drzewiecka, Agnieszka; Gruszka, Katarzyna; Kandarova, Helena; Willoughby, Jamin A; Guest, Robert; Schofield, Jane; Van Rompay, An R

    2018-06-01

    Assessment of ocular irritation potential is an international regulatory requirement in the safety evaluation of industrial and consumer products. None in vitro ocular irritation assays are capable of fully categorizing chemicals as stand-alone. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI consortium assessed the reliability of eight in vitro test methods and computational models as well as established a tiered-testing strategy. One of the selected assays was Bovine Corneal Opacity and Permeability (BCOP). In this project, the same corneas were used for measurement of opacity using the OP-KIT, the Laser Light-Based Opacitometer (LLBO) and for histopathological analysis. The results show that the accuracy of the BCOP OP-KIT in identifying Cat 1 chemicals was 73.8% while the accuracy was 86.3% for No Cat chemicals. BCOP OP-KIT false negative results were often related to an in vivo classification driven by conjunctival effects only. For the BCOP LLBO, the accuracy in identifying Cat 1 chemicals was 74.4% versus 88.8% for No Cat chemicals. The BCOP LLBO seems very promising for the identification of No Cat liquids but less so for the identification of solids. Histopathology as an additional endpoint to the BCOP test method does not reduce the false negative rate substantially for in vivo Cat 1 chemicals. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Cosmic rays, gas and dust in nearby anticentre clouds. I. CO-to-H2 conversion factors and dust opacities

    Science.gov (United States)

    Remy, Q.; Grenier, I. A.; Marshall, D. J.; Casandjian, J. M.

    2017-05-01

    Aims: We aim to explore the capabilities of dust emission and γ rays for probing the properties of the interstellar medium in the nearby anti-centre region, using γ-ray observations with the Fermi Large Area Telescope (LAT), and the thermal dust optical depth inferred from Planck and IRAS observations. We also aim to study massive star-forming clouds including the well known Taurus, Auriga, Perseus, and California molecular clouds, as well as a more diffuse structure which we refer to as Cetus. In particular, we aim at quantifying potential variations in cosmic-ray density and dust properties per gas nucleon across the different gas phases and different clouds, and at measuring the CO-to-H2 conversion factor, XCO, in different environments. Methods: We have separated six nearby anti-centre clouds that are coherent in velocities and distances, from the Galactic-disc background in H I 21-cm and 12CO 2.6-mm line emission. We have jointly modelled the γ-ray intensity recorded between 0.4 and 100 GeV, and the dust optical depth τ353 at 353 GHz as a combination of H I-bright, CO-bright, and ionised gas components. The complementary information from dust emission and γ rays was used to reveal the gas not seen, or poorly traced, by H I, free-free, and 12CO emissions, namely (I) the opaque H iand diffuse H2 present in the Dark Neutral Medium at the atomic-molecular transition, and (II) the dense H2 to be added where 12CO lines saturate. Results: The measured interstellar γ-ray spectra support a uniform penetration of the cosmic rays with energies above a few GeV through the clouds, from the atomic envelopes to the 12CO-bright cores, and with a small ± 9% cloud-to-cloud dispersion in particle flux. We detect the ionised gas from the H iiregion NGC 1499 in the dust and γ-ray emissions and measure its mean electron density and temperature. We find a gradual increase in grain opacity as the gas (atomic or molecular) becomes more dense. The increase reaches a factor of

  5. TU-E-201-01: Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionists

    Energy Technology Data Exchange (ETDEWEB)

    Rehani, M. [Massachusetts General Hospital (United States)

    2015-06-15

    Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bomb survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable, actions on

  6. TU-E-201-01: Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionists

    International Nuclear Information System (INIS)

    Rehani, M.

    2015-01-01

    Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bomb survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable, actions on

  7. An Empirical Determination of the Intergalactic Background Light Using Near-Infrared Deep Galaxy Survey Data Out to 5 Micrometers and the Gamma-Ray Opacity of the Universe

    Science.gov (United States)

    Scully, Sean T.; Malkan, Matthew A.; Stecker, Floyd W.

    2014-01-01

    We extend our previous model-independent determination of the intergalactic background light, based purely on galaxy survey data, out to a wavelength of 5 micrometers. Our approach enables us to constrain the range of photon densities, based on the uncertainties from observationally determined luminosity densities and colors. We further determine a 68% confidence upper and lower limit on the opacity of the universe to gamma-rays up to energies of 1.6/(1 + z) terraelectron volts. A comparison of our lower limit redshift-dependent opacity curves to the opacity limits derived from the results of both ground-based air Cerenkov telescope and Fermi-LAT observations of PKS 1424+240 allows us to place a new upper limit on the redshift of this source, independent of IBL modeling.

  8. Theory of wave propagation in magnetized near-zero-epsilon metamaterials: evidence for one-way photonic states and magnetically switched transparency and opacity.

    Science.gov (United States)

    Davoyan, Arthur R; Engheta, Nader

    2013-12-20

    We study propagation of transverse-magnetic electromagnetic waves in the bulk and at the surface of a magnetized epsilon-near-zero (ENZ) medium in a Voigt configuration. We reveal that in a certain range of material parameters novel regimes of wave propagation emerge; we show that the transparency of the medium can be altered with the magnetization leading either to magnetically induced Hall opacity or Hall transparency of the ENZ. In our theoretical study, we demonstrate that surface waves at the interface between either a transparent or an opaque Hall medium and a homogeneous medium may, under certain conditions, be predominantly one way. Moreover, we predict that one-way photonic surface states may exist at the interface of an opaque Hall ENZ and a regular metal, giving rise to the possibility for backscattering immune wave propagation and isolation.

  9. X-ray grating spectrometer for opacity measurements in the 50 eV to 250 eV spectral range at the LULI 2000 laser facility.

    Science.gov (United States)

    Reverdin, Charles; Thais, Frédéric; Loisel, Guillaume; Busquet, M; Bastiani-Ceccotti, S; Blenski, T; Caillaud, T; Ducret, J E; Foelsner, W; Gilles, D; Gilleron, F; Pain, J C; Poirier, M; Serres, F; Silvert, V; Soullie, G; Turck-Chieze, S; Villette, B

    2012-10-01

    An x-ray grating spectrometer was built in order to measure opacities in the 50 eV to 250 eV spectral range with an average spectral resolution ∼ 50. It has been used at the LULI-2000 laser facility at École Polytechnique (France) to measure the Δn = 0, n = 3 transitions of several elements with neighboring atomic number: Cr, Fe, Ni, and Cu in the same experimental conditions. Hence a spectrometer with a wide spectral range is required. This spectrometer features one line of sight looking through a heated sample at backlighter emission. It is outfitted with one toroidal condensing mirror and several flat mirrors cutting off higher energy photons. The spectral dispersion is obtained with a flatfield grating. Detection consists of a streak camera sensitive to soft x-ray radiation. Some experimental results showing the performance of this spectrometer are presented.

  10. X-ray grating spectrometer for opacity measurements in the 50 eV to 250 eV spectral range at the LULI 2000 laser facility

    International Nuclear Information System (INIS)

    Reverdin, Charles; Caillaud, T.; Gilleron, F.; Pain, J. C.; Silvert, V.; Soullie, G.; Villette, B.; Thais, Frédéric; Loisel, Guillaume; Blenski, T.; Poirier, M.; Busquet, M.; Bastiani-Ceccotti, S.; Serres, F.; Ducret, J. E.; Foelsner, W.; Gilles, D.; Turck-Chieze, S.

    2012-01-01

    An x-ray grating spectrometer was built in order to measure opacities in the 50 eV to 250 eV spectral range with an average spectral resolution ∼ 50. It has been used at the LULI-2000 laser facility at École Polytechnique (France) to measure the Δn = 0, n = 3 transitions of several elements with neighboring atomic number: Cr, Fe, Ni, and Cu in the same experimental conditions. Hence a spectrometer with a wide spectral range is required. This spectrometer features one line of sight looking through a heated sample at backlighter emission. It is outfitted with one toroidal condensing mirror and several flat mirrors cutting off higher energy photons. The spectral dispersion is obtained with a flatfield grating. Detection consists of a streak camera sensitive to soft x-ray radiation. Some experimental results showing the performance of this spectrometer are presented.

  11. A Determination of the Intergalactic Redshift Dependent UV-Optical-NIR Photon Density Using Deep Galaxy Survey Data and the Gamma-ray Opacity of the Universe

    Science.gov (United States)

    Stecker, Floyd W.; Malkan, Matthew A.; Scully, Sean T.

    2012-01-01

    We calculate the intensity and photon spectrum of the intergalactic background light (IBL) as a function of redshift using an approach based on observational data obtained in many different wavelength bands from local to deep galaxy surveys. This allows us to obtain an empirical determination of the IBL and to quantify its observationally based uncertainties. Using our results on the IBL, we then place 68% confidence upper and lower limits on the opacity of the universe to gamma-rays, free of the theoretical assumptions that were needed for past calculations. We compare our results with measurements of the extragalactic background light and upper limits obtained from observations made by the Fermi Gamma-ray Space Telescope.

  12. X-ray grating spectrometer for opacity measurements in the 50 eV to 250 eV spectral range at the LULI 2000 laser facility

    Energy Technology Data Exchange (ETDEWEB)

    Reverdin, Charles; Caillaud, T.; Gilleron, F.; Pain, J. C.; Silvert, V.; Soullie, G.; Villette, B. [CEA, DAM, DIF, 91297 Arpajon (France); Thais, Frederic; Loisel, Guillaume; Blenski, T.; Poirier, M. [CEA, DSM, IRAMIS, Service Photons, Atomes et Molecules, 91191 Gif-sur-Yvette (France); Busquet, M. [ARTEP Inc, Ellicott City, Maryland 21042 (United States); Bastiani-Ceccotti, S.; Serres, F. [LULI, Ecole Polytechnique, CNRS, CEA, UPMC, route de Saclay, 91128 Palaiseau (France); Ducret, J. E. [CELIA, UMR5107, CEA, CNRS, Universite de Bordeaux, 33400 Talence (France); Foelsner, W. [Max Planck Instituet fuer Quantum Optik, 85748 Garching (Germany); Gilles, D.; Turck-Chieze, S. [CEA, DSM, IRFU, Service d' astrophysique, 91191 Gif-sur-Yvette (France)

    2012-10-15

    An x-ray grating spectrometer was built in order to measure opacities in the 50 eV to 250 eV spectral range with an average spectral resolution {approx} 50. It has been used at the LULI-2000 laser facility at Ecole Polytechnique (France) to measure the {Delta}n = 0, n = 3 transitions of several elements with neighboring atomic number: Cr, Fe, Ni, and Cu in the same experimental conditions. Hence a spectrometer with a wide spectral range is required. This spectrometer features one line of sight looking through a heated sample at backlighter emission. It is outfitted with one toroidal condensing mirror and several flat mirrors cutting off higher energy photons. The spectral dispersion is obtained with a flatfield grating. Detection consists of a streak camera sensitive to soft x-ray radiation. Some experimental results showing the performance of this spectrometer are presented.

  13. Multilevel Analysis of Trachomatous Trichiasis and Corneal Opacity in Nigeria: The Role of Environmental and Climatic Risk Factors on the Distribution of Disease.

    Science.gov (United States)

    Smith, Jennifer L; Sivasubramaniam, Selvaraj; Rabiu, Mansur M; Kyari, Fatima; Solomon, Anthony W; Gilbert, Clare

    2015-01-01

    The distribution of trachoma in Nigeria is spatially heterogeneous, with large-scale trends observed across the country and more local variation within areas. Relative contributions of individual and cluster-level risk factors to the geographic distribution of disease remain largely unknown. The primary aim of this analysis is to assess the relationship between climatic factors and trachomatous trichiasis (TT) and/or corneal opacity (CO) due to trachoma in Nigeria, while accounting for the effects of individual risk factors and spatial correlation. In addition, we explore the relative importance of variation in the risk of trichiasis and/or corneal opacity (TT/CO) at different levels. Data from the 2007 National Blindness and Visual Impairment Survey were used for this analysis, which included a nationally representative sample of adults aged 40 years and above. Complete data were available from 304 clusters selected using a multi-stage stratified cluster-random sampling strategy. All participants (13,543 individuals) were interviewed and examined by an ophthalmologist for the presence or absence of TT and CO. In addition to field-collected data, remotely sensed climatic data were extracted for each cluster and used to fit Bayesian hierarchical logistic models to disease outcome. The risk of TT/CO was associated with factors at both the individual and cluster levels, with approximately 14% of the total variation attributed to the cluster level. Beyond established individual risk factors (age, gender and occupation), there was strong evidence that environmental/climatic factors at the cluster-level (lower precipitation, higher land surface temperature, higher mean annual temperature and rural classification) were also associated with a greater risk of TT/CO. This study establishes the importance of large-scale risk factors in the geographical distribution of TT/CO in Nigeria, supporting anecdotal evidence that environmental conditions are associated with increased

  14. Characteristics of interventional cardiologists and their work practices for the study on radiation-induced lens opacities based on the methodology developed by ELDO—preliminary results

    International Nuclear Information System (INIS)

    Domienik, Joanna; Gryglak, Szymon; Jurewicz, Joanna

    2016-01-01

    Preliminary results of the Polish epidemiology study on eye lens opacities among interventional cardiologists (ICs), based on the methodology proposed by ELDO (epidemiological studies of radio-induced cataracts in interventional cardiologists and radiologists: methodology implementation), are presented. The aim of the study is to test the hypothesis concerning the excess risk of cataract in the group of ICs. The first results concern the study population characteristics, including the most important confounding factors for cataract, as well as a detailed description of the work practices in interventional cardiology needed in order to reconstruct the cumulative eye lens dose. The data from 69 ICs and 23 controls collected based on the general medical questionnaire and the occupational questionnaire (for ICs only) were analyzed. The mean age of ICs and of the control group was 41 and 44, respectively, while the mean duration of work for exposed physicians was 9 years. The analysis of the data from the occupational questionnaire concerning the procedures performed, the use of various access routes, as well as radiation protection tools (eye lens glasses, ceiling suspended transparent shield, etc.) are also presented. On the basis of this information and additional assumptions about the doses per procedure (as well as reduction factors for various types of radiation measures), the cumulative doses to the eye lens of ICs were evaluated. They ranged up to 1.55 Sv and 0.4 Sv for left and right eye, respectively; however, the dose to only 3% of ICs exceeded the new threshold for development of eye lens opacities (0.5 Gy) proposed by the ICRP

  15. Correlação dos achados tomográficos com parâmetros de função pulmonar na fibrose pulmonar idiopática em não fumantes Correlation of tomographic findings with pulmonary function parameters in nonsmoking patients with idiopathic pulmonary fibrosis

    Directory of Open Access Journals (Sweden)

    Agnaldo José Lopes

    2007-12-01

    Full Text Available OBJETIVO: Correlacionar os achados tomográficos com os parâmetros de função pulmonar em portadores de fibrose pulmonar idiopática (FPI. MÉTODOS: Foi realizado um estudo de corte transversal, em que foram avaliados 30 pacientes não tabagistas, portadores de FPI. Utilizando um sistema de escore semiquantitativo, os seguintes achados na tomografia computadorizada de alta resolução (TCAR foram quantificados: extensão total da doença intersticial (Tot, infiltrado reticular e faveolamento (Ret+Fav, e opacidade em vidro fosco (Vif. As variáveis funcionais foram mensuradas através de espirometria, técnica de oscilações forçadas (TOF, método da diluição com hélio e método da respiração única para medir a capacidade de difusão do monóxido de carbono (DLCO. RESULTADOS: Dos 30 pacientes estudados, 18 eram mulheres e 12 eram homens, com média de idade de 70,9 anos. Foram encontradas correlações significativas de Tot e Ret+Fav com as medidas de capacidade vital forçada (CVF, capacidade pulmonar total (CPT, DLCO e complacência dinâmica do sistema respiratório (correlações negativas, e de Vif com volume residual/CPT (correlação positiva. A relação fluxo expiratório forçado entre 25 e 75% da CVF/CVF (FEF25-75%/CVF correlacionou-se positivamente com Tot, Ret+Fav e Vif. CONCLUSÕES: Em portadores de FPI, as medidas de volume, difusão e complacência dinâmica são as variáveis fisiológicas que melhor refletem a extensão da doença intersticial na TCAR.OBJECTIVE: To correlate tomographic findings with pulmonary function parameters in patients with idiopathic pulmonary fibrosis (IPF. METHODS: A cross-sectional study was carried out, in which 30 nonsmoking patients with IPF were evaluated. Using a semiquantitative scoring system, the following high-resolution computerized tomography (HRCT findings were quantified: total interstitial disease (TID, reticular abnormality/honeycombing, and ground-glass opacity (GGO. The

  16. Early Indicators of Treatment Success After Percutaneous Radiofrequency of Pulmonary Tumors

    International Nuclear Information System (INIS)

    Anderson, Ewan Mark; Lees, W. R.; Gillams, A. R.

    2009-01-01

    We retrospectively reviewed the imaging of patients after radiofrequency ablation (RFA) of lung metastases performed at our institution to assess the usefulness of ground glass opacification (GGO) margin for the prediction of complete tumor ablation. From January 2004 to March 2007, patients were identified where there was a postprocedure thin collimation scan to allow multiplanar reformatting, either immediately or at 24 h and at least 6 months of imaging follow-up. Thirty-six tumors in 22 patients were identified. The scans were assessed for the presence and width of GGO margin, and minimal and maximal dimensions were measured. A second reviewer, blinded to the outcome of the postprocedure assessment, reviewed the follow-up imaging for recurrence. The recurrence group had larger tumors (p = 0.045) and smaller mean minimal GGO margin width (p = 0.0001). Multivariate binary regression analysis confirmed that the minimal GGO margin was significantly (p 5 mm is the minimal margion required to ensure complete tumor ablation.

  17. Pulmonary metastatic calcification: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Bozi, Lilian Christine Franchiotti [Radiology, Hospital Universitario Antonio Pedro (HUAP), Niteroi, RJ (Brazil); Melo, Alessandro Severo Alves de; Marchiori, Edson, E-mail: edmarchiori@gmail.com [Department of Radiology, School of Medicine, Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil)

    2012-09-15

    The present report describes the case of a 48-year-old female patient suffering from chronic renal failure on dialysis for 13 years. She presented with hemoptysis, fever, productive cough and dyspnoea. Chest radiography showed predominance of ill-defined opacities in the middle and lower lung fields, bilaterally. Chest computed tomography showed ground glass opacities associated with poorly defined centrilobular nodules with ground-glass attenuation. The patient was submitted to bronchoalveolar lavage that was negative for mycobacteria and fungi. On the basis of such findings, open lung biopsy was performed, which revealed metastatic pulmonary calcification. (author)

  18. Tritiated water exposure disrupts myofibril structure and induces mis-regulation of eye opacity and DNA repair genes in zebrafish early life stages.

    Science.gov (United States)

    Arcanjo, Caroline; Armant, Olivier; Floriani, Magali; Cavalie, Isabelle; Camilleri, Virginie; Simon, Olivier; Orjollet, Daniel; Adam-Guillermin, Christelle; Gagnaire, Béatrice

    2018-04-27

    Tritium ( 3 H) is a radioactive isotope of hydrogen. In the environment, the most common form of tritium is tritiated water (HTO). The present study aimed to identify early biomarkers of HTO contamination through the use of an aquatic model, the zebrafish (Danio rerio). We used the zebrafish embryo-larvae model to investigate the modes of action of HTO exposure at dose rates of 0.4 and 4 mGy/h, dose rates expected to induce deleterious effects on fish. Zebrafish were exposed to HTO from 3 hpf (hours post fertilization) to 96 hpf. The transcriptomic effects were investigated 24 h and 96 h after the beginning of the contamination, using mRNAseq. Results suggested an impact of HTO contamination, regardless of the dose rate, on genes involved in muscle contraction (tnnt2d, tnni2a.4, slc6a1a or atp2a1l) and eye opacity (crygm2d9, crygmxl1, mipb or lim2.3) after 24 h of contamination. Interestingly, an opposite differential expression was highlighted in genes playing a role in muscle contraction and eye opacity in 24 hpf embryos when comparing dose rates, suggesting an onset of DNA protective mechanisms. The expression of h2afx and ddb2 involved in DNA repair was enhanced in response to HTO exposure. The entrainment of circadian clock and the response to H 2 O 2 signalling pathways were enriched at 96 hpf at 0.4 mGy/h and in both stages after 4 mGy/h. Genes involved in ROS scavenging were differentially expressed only after 24 h of exposure for the lowest dose rate, suggesting the onset of early protective mechanisms against oxidative stress. Effects highlighted on muscle at the molecular scale were confirmed at a higher biological scale, as electron microscopy observations revealed sarcomere impairments in 96 hpf larvae for both dose rates. Together with other studies, the present work provides useful data to better understand modes of action of tritium on zebrafish embryos-larvae. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Persistent Epithelial Defects and Corneal Opacity After Collagen Cross-Linking With Substitution of Dextran (T-500) With Dextran Sulfate in Compounded Topical Riboflavin.

    Science.gov (United States)

    Höllhumer, Roland; Watson, Stephanie; Beckingsale, Peter

    2017-03-01

    Collagen cross-linking (CXL) is a commonly performed procedure to prevent the progression of keratoconus. Riboflavin is an essential part of the procedure, which facilitates both the cross-linking process and protection of intraocular structures. Dextran can be added to riboflavin to create an isotonic solution. This case report highlights the importance of compounding riboflavin with the correct dextran solution. A retrospective case series. Six eyes of 4 male patients with keratoconus aged from 20 to 38 years underwent CXL with substitution of 20% dextran (T-500) with 20% dextran sulfate in a compounded riboflavin 0.1% solution. Postoperatively, persistent corneal epithelial defects, stromal haze, and then scarring occurred. Corneal transplantation was performed for visual rehabilitation but was complicated by graft rejection followed by failure (n = 1 eye), dehiscence (n = 4), cataract (n = 2), post-laser ablation haze (n = 1), and steroid-induced glaucoma (n = 2). The visual outcome was dextran (T-500) with dextran sulfate in riboflavin solutions during CXL results in loss of vision from permanent corneal opacity. Residual host changes may compromise the results of corneal transplantation.

  20. Smoke opacity of agricultural tractor using biodiesel in function of weather conditions in the time of testing; Opacidade da fumaca de trator agricola utilizando biodiesel em funcao das condicoes climaticas no horario de execucao do ensaio

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Afonso; Camara, Felipe T. da; Oliveira, Melina Cais Jejcic de; Furlani, Carlos E.A.; Silva, Rouverson Pereira da; Mello Junior, Jose G.S. [Universidade Estadual Paulista (FCAV/UNESP), SP (Brazil). Fac. de Ciencias Agrarias e Veterinarias. Dept. de Engenharia Rural], E-mail: afonso@fcav.unesp.br

    2009-07-01

    The biodiesel highlights as an alternative fuel to petroleum diesel, due its similar diesel properties, allowing the biodiesel replace the diesel without engine's alterations. The present work aimed measure the tractor's smoke opacity running with biodiesel in three proportions (B0, B50, and B100), in function of environment temperature and moisture in eight times (1h, 4h, 7h, 10h, 13h, 16h, 19h, and 22h). The experiment was conducted in the Rural Engineering Department of UNESP, Jaboticabal, Brazil, it was used a Valtra BM100 4x2 TDA (74kW - 100 cv) tractor, in the engine at 2350 rpm, and a soybean's distillated ethylic Biodiesel produced by USP - Laboratory of Development of Clean Technologies, in Ribeirao Preto, Brazil. The results evidence smoke opacity reduction in order to environment temperature reduction and when increased the moisture. (author)

  1. Analysis of the influence of the plasma thermodynamic regime in the spectrally resolved and mean radiative opacity calculations of carbon plasmas in a wide range of density and temperature

    International Nuclear Information System (INIS)

    Gil, J.M.; Rodriguez, R.; Martel, P.; Florido, R.; Rubiano, J.G.; Mendoza, M.A.; Minguez, E.

    2013-01-01

    In this work the spectrally resolved, multigroup and mean radiative opacities of carbon plasmas are calculated for a wide range of plasma conditions which cover situations where corona, local thermodynamic and non-local thermodynamic equilibrium regimes are found. An analysis of the influence of the thermodynamic regime on these magnitudes is also carried out by means of comparisons of the results obtained from collisional-radiative, corona or Saha–Boltzmann equations. All the calculations presented in this work were performed using ABAKO/RAPCAL code. -- Highlights: ► Spectrally resolved, multigroup and mean radiative opacities of carbon plasmas are calculated. ► Corona, local thermodynamic and non-local thermodynamic equilibrium regimes are analyzed. ► Simulations performed using the computational package ABAKO/RAPCAL. ► A criterion for the establishment of the thermodynamic regime is proposed.

  2. Biodiesel of palm oil in tractor agricultural: opacity of smoke in the light of storage time; Biodiesel de dende em trator agricola: opacidade da fumaca em funcao do tempo de armazenamento

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Leomar P. [Instituto Federal do Triangulo Mineiro (IFTM), Uberlandia, MG (Brazil)], email: leomaragro@yahoo.com.br; Lopes, Afonso; Oliveira, Melina C.J. [Universidade Estadual Paulista Julio de Mesquita Filho (FCAV/UNESP), Jaboticabal, SP (Brazil). Fac. de Ciencias Agrarias e Veterinarias. Dept. de Engenharia Rural; Camara, Felipe T. [Universidade Federal do Ceara (UFC), Cariri, CE (Brazil)

    2011-07-01

    The scenario of atmospheric emissions world characterized-if, in recent years, due to a series of technical factors, economic and political, by the need to reduce the consumption of petroleum. The objective of this work was to evaluate the opacity of smoke of a motor of a tractor agricultural operating with biodiesel of palm oil with different periods of storage. The experiment was conducted in the Laboratory of machinery and agricultural mechanization of Rural Engineering Department of UNESP, Jaboticabal, SP. In this study,-if a tractor Valtra BM 110 4x2 TDA 73,6 kW (100 cv) in engine 2.350 rpm. The experimental design was completely randomized, in factorial scheme 5x3, with 3 repetitions. The combinations of factors were five proportions of mixing biodiesel for diesel (B0, B5, B25, B 50 and B100, that the number indicates the percentage of biodiesel for diesel) and three storage times in condition environment (0, 3 and 6 months). The results showed that in relation to B0, when used biodiesel in the proportion of B100, the opacity of smoke reduced in 50.4% and the time of storage of biodiesel not committed the opacity of smoke from combustion of the engine. (author)

  3. Gas and dust in the star-forming region ρ Oph A. The dust opacity exponent β and the gas-to-dust mass ratio g2d

    Science.gov (United States)

    Liseau, R.; Larsson, B.; Lunttila, T.; Olberg, M.; Rydbeck, G.; Bergman, P.; Justtanont, K.; Olofsson, G.; de Vries, B. L.

    2015-06-01

    Aims: We aim at determining the spatial distribution of the gas and dust in star-forming regions and address their relative abundances in quantitative terms. We also examine the dust opacity exponent β for spatial and/or temporal variations. Methods: Using mapping observations of the very dense ρ Oph A core, we examined standard 1D and non-standard 3D methods to analyse data of far-infrared and submillimetre (submm) continuum radiation. The resulting dust surface density distribution can be compared to that of the gas. The latter was derived from the analysis of accompanying molecular line emission, observed with Herschel from space and with APEX from the ground. As a gas tracer we used N2H+, which is believed to be much less sensitive to freeze-out than CO and its isotopologues. Radiative transfer modelling of the N2H+ (J = 3-2) and (J = 6-5) lines with their hyperfine structure explicitly taken into account provides solutions for the spatial distribution of the column density N(H2), hence the surface density distribution of the gas. Results: The gas-to-dust mass ratio is varying across the map, with very low values in the central regions around the core SM 1. The global average, = 88, is not far from the canonical value of 100, however. In ρ Oph A, the exponent β of the power-law description for the dust opacity exhibits a clear dependence on time, with high values of 2 for the envelope-dominated emission in starless Class -1 sources to low values close to 0 for the disk-dominated emission in Class III objects. β assumes intermediate values for evolutionary classes in between. Conclusions: Since β is primarily controlled by grain size, grain growth mostly occurs in circumstellar disks. The spatial segregation of gas and dust, seen in projection toward the core centre, probably implies that, like C18O, also N2H+ is frozen onto the grains. Based on observations with APEX, which is a 12 m diameter submillimetre telescope at 5100 m altitude on Llano Chajnantor

  4. Opacity of iron, nickel, and copper plasmas in the x-ray wavelength range: Theoretical interpretation of 2p-3d absorption spectra

    International Nuclear Information System (INIS)

    Blenski, T.; Loisel, G.; Poirier, M.; Thais, F.; Arnault, P.; Caillaud, T.; Fariaut, J.; Gilleron, F.; Pain, J.-C.; Porcherot, Q.; Reverdin, C.; Silvert, V.; Villette, B.; Bastiani-Ceccotti, S.; Turck-Chieze, S.; Foelsner, W.; Gaufridy de Dortan, F. de

    2011-01-01

    This paper deals with theoretical studies on the 2p-3d absorption in iron, nickel, and copper plasmas related to LULI2000 (Laboratoire pour l'Utilisation des Lasers Intenses, 2000J facility) measurements in which target temperatures were of the order of 20 eV and plasma densities were in the range 0.004-0.01 g/cm 3 . The radiatively heated targets were close to local thermodynamic equilibrium (LTE). The structure of 2p-3d transitions has been studied with the help of the statistical superconfiguration opacity code sco and with the fine-structure atomic physics codes hullac and fac. A new mixed version of the sco code allowing one to treat part of the configurations by detailed calculation based on the Cowan's code rcg has been also used in these comparisons. Special attention was paid to comparisons between theory and experiment concerning the term features which cannot be reproduced by sco. The differences in the spin-orbit splitting and the statistical (thermal) broadening of the 2p-3d transitions have been investigated as a function of the atomic number Z. It appears that at the conditions of the experiment the role of the term and configuration broadening was different in the three analyzed elements, this broadening being sensitive to the atomic number. Some effects of the temperature gradients and possible non-LTE effects have been studied with the help of the radiative-collisional code scric. The sensitivity of the 2p-3d structures with respect to temperature and density in medium-Z plasmas may be helpful for diagnostics of LTE plasmas especially in future experiments on the Δn=0 absorption in medium-Z plasmas for astrophysical applications.

  5. Radiation-related posterior lenticular opacities in Hiroshima and Nagasaki atomic bomb survivors based on T65DR and DS86 dosimetry systems

    International Nuclear Information System (INIS)

    Otake, Masanori; Schull, W.J.

    1989-10-01

    This paper investigates the quantitative relationship of ionizing radiation to the occurrence of posterior lenticular opacities among the survivors of the atomic bombings of Hiroshima and Nagasaki, as suggested by the DS86 dosimetry system. DS86 doses are available for 1,983 (93.4%) of the 2,124 A-bomb survivors analyzed in 1982. In the DS86 system, both gamma-ray and neutron regression coefficients for the best-fitting model are positive and highly significant for the estimated energy deposited in the eye, here termed the eye organ dose. The DS86 gamma regression coefficient is almost the same as that associated with the T65DR gamma kerma, the ratio of the two coefficients being 1.1 (95% confidence limits: 0.5 - 2.3) for D86 kerma in the individual data. The relative biological effectiveness (RBE) values based on the individual gamma and neutron components of the DS86 eye organ dose are estimated to be 32.4 + 0.73/(D ν - 0.06)>0 with the 95% confidence limits ranging from 11.8 to 88.8 + 1.39/(D ν - 0.06)>0, where D ν is the neutron dose in gray. It is suggested that the neutron component could be more important for the eyes than for other sites of the body. Finally, it is interesting to observe that a linear-quadratic gamma and linear neutron model with two thresholds, which fits the data less well, produces very similar estimates of the two thresholds as the linear gamma-linear neutron-response model. In this model, however, the regression coefficient is not significantly associated with the quadratic gamma response. (J.P.N.)

  6. Prevalence of Hypertension and Association of Obesity with Hypertension in School Ggoing Children of Surat City, Western India

    Directory of Open Access Journals (Sweden)

    Salvi S. Shah

    2013-08-01

    Full Text Available Purpose: The association of obesity with hypertension has been recognized for the decades which are the important risk factors for the cardiovascular disease. So the purpose of the present study was to determine association of obesity with hypertension in school going children of Surat. Methodology: School going children aged between 12-18 years, of five schools in Surat were selected for the study. Height and weight were measured and BMI was calculated. Blood pressure measurements were taken as per recommendation of American heart society and family history of hypertension has also been assessed. Hypertension was considered if blood pressure is more than 95th percentile according to the update of task force report and Obesity was diagnosed by BMI for age. Results: Of 682 children, 8.94% were obese and 20.09% were hypertensive. Conclusion: Obesity is strongly associated with hypertension in children and both together may risk factors for later coronary disease.

  7. Idiopathic interstitial pneumonias: radiologic-pathologic correlation

    International Nuclear Information System (INIS)

    Yoon, Young Cheol; Suh, Gee Young; Han, Joung Ho; Lee, Kyung Soo

    2002-01-01

    Idiopathic interstitial pneumonias are at present classified as one of four types: usual, nonspecific, acute, or desquamative. The acute form has the worst prognosis, followed by the usual and the nonspecific form; it is in desquamative cases that prognosis is best. At high-resolution CT, usual interstitial pneumonia, the most frequent type, manifests as patchy subpleural areas of ground-glass attenuation, irregular linear opacity, and honeycombing, which the nonspecific type, the second most frequent, appears as subpleural patchy areas of ground-glass attenuation with associated areas of irregular linear opacity. Acute interstitial pneumonia demonstrates extensive bilateral airspace consolidation and patchy or diffuse bilateral areas of ground-glass attenuation in middle and lower lung zones

  8. Urinary ascites in a preterm female neonate: a rare case report

    African Journals Online (AJOL)

    hyponatremia and hyperkalemia, and blood urea nitrogen levels will be increased [5]. Diagnosis of urinary ascites can be made by abdominal radiograph and USG abdomen. Abdominal radiograph will show central pooling of gut loops in abdomen and ground glass opacity in flanks. USG abdomen can be confirmative.

  9. Exogenous lipoid pneumonia: high-resolution CT findings

    International Nuclear Information System (INIS)

    Lee, J.S.; Song, K.S.; Lim, T.H.; Im, J.G.; Seo, J.B.

    1999-01-01

    The aim of this study was to assess high-resolution computed tomography (HRCT) findings of exogenous lipoid pneumonia. High-resolution computed tomography was obtained in 25 patients with proven exogenous lipoid pneumonia resulting from aspiration of squalene (derived from shark liver oil). Diagnosis was based on biopsy (n = 9), bronchoalveolar lavage (n = 8), or sputum cytology and clinical findings (n = 8). The clinical history of taking squalene was confirmed in all patients. The CT findings were classified into three patterns: diffuse ground-glass opacity, consolidation, and interstitial abnormalities. Distribution of the abnormalities, duration of taking squalene, predisposing factors for aspiration, and route of administration were analyzed. Ten patients showed diffuse ground-glass opacity pattern. Seven of 10 patients had predisposing conditions such as unconsciousness, pharyngeal dysmotility, or motor disturbances, and 6 patients had a recent history of taking large amount of squalene through nasal route. Seven patients who had consolidation pattern had a history of taking squalene for several months and did not have any predisposing factor. All of the 5 patients who had a pattern of interstitial abnormalities had a history of taking squalene longer than 1 year and showed segmental distribution of interstitial thickening with interposing ground-glass opacities. Three patients simultaneously had two different patterns at different lobes of the lung. The HRCT findings of lipoid pneumonia are ground-glass opacities, consolidation, and interstitial abnormalities. These HRCT findings with appropriate inquiries could be useful for diagnosis of exogeneous lipoid pneumonia. (orig.)

  10. Metastatic pulmonary calcification: high-resolution computed tomography findings in 23 cases

    Directory of Open Access Journals (Sweden)

    Luciana Camara Belém

    Full Text Available Abstract Objective: The aim of this study was to evaluate the high-resolution computed tomography (HRCT findings in patients diagnosed with metastatic pulmonary calcification (MPC. Materials and Methods: We retrospectively reviewed the HRCT findings from 23 cases of MPC [14 men, 9 women; mean age, 54.3 (range, 26-89 years]. The patients were examined between 2000 and 2014 in nine tertiary hospitals in Brazil, Chile, and Canada. Diagnoses were established by histopathologic study in 18 patients and clinical-radiological correlation in 5 patients. Two chest radiologists analyzed the images and reached decisions by consensus. Results: The predominant HRCT findings were centrilobular ground-glass nodules (n = 14; 60.9%, consolidation with high attenuation (n = 10; 43.5%, small dense nodules (n = 9; 39.1%, peripheral reticular opacities associated with small calcified nodules (n = 5; 21.7%, and ground-glass opacities without centrilobular ground-glass nodular opacity (n = 5; 21.7%. Vascular calcification within the chest wall was found in four cases and pleural effusion was observed in five cases. The abnormalities were bilateral in 21 cases. Conclusion: MPC manifested with three main patterns on HRCT, most commonly centrilobular ground-glass nodules, often containing calcifications, followed by dense consolidation and small solid nodules, most of which were calcified. We also described another pattern of peripheral reticular opacities associated with small calcified nodules. These findings should suggest the diagnosis of MPC in the setting of hypercalcemia.

  11. Metastatic pulmonary calcification: high-resolution computed tomography findings in 23 cases

    Energy Technology Data Exchange (ETDEWEB)

    Belem, Luciana Camara; Souza, Carolina A.; Souza Junior, Arthur Soares; Escuissato, Dante Luiz; Hochhegger, Bruno; Nobre, Luiz Felipe; Rodrigues, Rosana Souza; Gomes, Antonio Carlos Portugal; Silva, Claudio S.; Guimaraes, Marcos Duarte; Zanetti, Glaucia; Marchiori, Edson, E-mail: edmarchiori@gmail.com [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil); Ottawa Hospital Research Institute, University of Ottawa, (Canada); Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil); Ultra X, Sao Jose do Rio Preto, SP (Brazil); Universidade Federal do Parana (UFPR), Curitiba, PR (Brazil); Universidade Federal de Ciencias da Saude de Porto Alegre (UFCSPA), Porto Alegre, RS (Brazil); Universidade Federal de Santa Catarina (UFSC), Florianopolis, SC (Brazil). Hospital Universitario

    2017-07-15

    Objective: The aim of this study was to evaluate the high-resolution computed tomography (HRCT) findings in patients diagnosed with metastatic pulmonary calcification (MPC). Materials and Methods: We retrospectively reviewed the HRCT findings from 23 cases of MPC [14 men, 9 women; mean age, 54.3 (range, 26-89) years]. The patients were examined between 2000 and 2014 in nine tertiary hospitals in Brazil, Chile, and Canada. Diagnoses were established by histopathologic study in 18 patients and clinical-radiological correlation in 5 patients. Two chest radiologists analyzed the images and reached decisions by consensus. Results: The predominant HRCT findings were centrilobular ground-glass nodules (n = 14; 60.9%), consolidation with high attenuation (n = 10; 43.5%), small dense nodules (n = 9; 39.1%), peripheral reticular opacities associated with small calcified nodules (n = 5; 21.7%), and ground-glass opacities without centrilobular ground-glass nodular opacity (n = 5; 21.7%). Vascular calcification within the chest wall was found in four cases and pleural effusion was observed in five cases. The abnormalities were bilateral in 21 cases. Conclusion: MPC manifested with three main patterns on HRCT, most commonly centrilobular ground-glass nodules, often containing calcifications, followed by dense consolidation and small solid nodules, most of which were calcified. We also described another pattern of peripheral reticular opacities associated with small calcified nodules. These findings should suggest the diagnosis of MPC in the setting of hypercalcemia. (author)

  12. Two Cases of Chloromethylisothiazolinone and Methylisothiazolinone-associated Toxic Lung Injury.

    Science.gov (United States)

    Lee, Eun; Son, Seung Kook; Yoon, Jisun; Cho, Hyun Ju; Yang, Song I; Jung, Sungsu; Do, Kyung Hyun; Cho, Young Ah; Lee, So Yeon; Park, Dong Uk; Hong, Soo Jong

    2018-04-16

    Previous animal studies have not conclusively determined the association between exposure to humidifier disinfectants (HDs) containing 5-chloro-2-methyl-4-isothiazolin-3-one (CMIT) and/or 2-methyl-4-isothiazolin-3-one (MIT) and development of HD-associated lung injuries. Nonetheless, patients exposed to HDs containing only CMIT and/or MIT showed clinically similar lung injuries to those exposed to HDs containing polyhexamethylene guanidine (PHMG) or oligo (2-[2-ethoxy]ethoxyethyl) guanidinium chloride (PGH). Here, we report twin sisters with lung injuries associated with exposure to CMIT/MIT-containing HDs. At 6 months of age, a younger twin sister presented with the 3-day history of cough, sputum, and respiratory difficulty. Chest radiography revealed multiple patchy consolidation and ground-glass opacities with pneumothorax and pneumomediastinum. Thoracostomy was performed due to pneumothorax at admission and she was discharged at 11 days of hospitalization. At 5 years of age, multiple tiny nodules and faint centrilobular ground-glass opacities were observed with the small pneumatocele. The elder sister visited a tertiary hospital due to dyspnea at 12 months of age. Chest radiography showed consolidation, pneumomediastinum, and pulmonary interstitial emphysema. There was no response to the administration of immunosuppressant drugs and antifibrotic agents. At 5 years of age, chest CT revealed ground-glass opacity and multiple tiny centrilobular ground-glass opacities nodules in both lungs with exercise intolerance. © 2018 The Korean Academy of Medical Sciences.

  13. Pulmonary abnormalities caused by interferon with or without herbal drug. CT and radiographic findings

    International Nuclear Information System (INIS)

    Ikezoe, Junpei; Kohno, Nobuaki; Johkoh, Takeshi; Kozuka, Takahiro; Kawase, Ichiro; Ebara, Hidemi; Kamisako, Toshinori; Adachi, Yukihiko.

    1995-01-01

    Chest radiographic and CT findings of acute diffuse interstitial lung disease due to interferon administration were reviewed. The subjects were 5 patients who were treated with interferon alone (n=4) or combined with traditional herbal drug treatment (n=one) for chronic hepatitis C. Respiratory symptoms consisted of cough (n=4), fever (n=4), dyspnea (n=3), and chest pain (n=one). CT findings were peripherally predominant non-segmental consolidation (n=3) with or without ground-glass opacities, and intralobular reticulation with ground-glass opacities (n=2). Neither honeycombing nor lung distortion was observed on CT. Chest radiographs showed airspace consolidation with or without ground-glass opacities (n=4) and reticulonodular lesions with ground-glass opacities (n=one). Although radiological findings of interferon-induced lung abnormalities were not uniform, it appears that these findings reflect lung hypersensitivity to interferon. Recognizing radiographic and CT findings of interferon-induced lung abnormalities is required because they are likely to occur associated with increasing use of this drug in the clinical setting. (N.K.)

  14. Pulmonary abnormalities caused by interferon with or without herbal drug. CT and radiographic findings

    Energy Technology Data Exchange (ETDEWEB)

    Ikezoe, Junpei; Kohno, Nobuaki; Johkoh, Takeshi; Kozuka, Takahiro; Kawase, Ichiro [Osaka Univ. (Japan). Faculty of Medicine; Ebara, Hidemi; Kamisako, Toshinori; Adachi, Yukihiko

    1995-02-01

    Chest radiographic and CT findings of acute diffuse interstitial lung disease due to interferon administration were reviewed. The subjects were 5 patients who were treated with interferon alone (n=4) or combined with traditional herbal drug treatment (n=one) for chronic hepatitis C. Respiratory symptoms consisted of cough (n=4), fever (n=4), dyspnea (n=3), and chest pain (n=one). CT findings were peripherally predominant non-segmental consolidation (n=3) with or without ground-glass opacities, and intralobular reticulation with ground-glass opacities (n=2). Neither honeycombing nor lung distortion was observed on CT. Chest radiographs showed airspace consolidation with or without ground-glass opacities (n=4) and reticulonodular lesions with ground-glass opacities (n=one). Although radiological findings of interferon-induced lung abnormalities were not uniform, it appears that these findings reflect lung hypersensitivity to interferon. Recognizing radiographic and CT findings of interferon-induced lung abnormalities is required because they are likely to occur associated with increasing use of this drug in the clinical setting. (N.K.).

  15. Clinical characteristics and computed tomography findings of pulmonary toxoplasmosis after hematopoietic stem cell transplantation.

    Science.gov (United States)

    Sumi, Masahiko; Norose, Kazumi; Hikosaka, Kenji; Kaiume, Hiroko; Takeda, Wataru; Kirihara, Takehiko; Kurihara, Taro; Sato, Keijiro; Ueki, Toshimitsu; Hiroshima, Yuki; Kuraishi, Hiroshi; Watanabe, Masahide; Kobayashi, Hikaru

    2016-12-01

    The prognosis of pulmonary toxoplasmosis, including disseminated toxoplasmosis involving the lungs, following hematopoietic stem cell transplantation (HSCT) is extremely poor due to the difficulties associated with early diagnosis and the rapidly progressive deterioration of multiorgan function. In our institution, we identified nine cases of toxoplasmosis, representing incidences of 2.2 and 19.6 % among all HSCT recipients and seropositive HSCT recipients, respectively. Of the patients with toxoplasmosis, six had pulmonary toxoplasmosis. Chest computed tomography (CT) findings revealed centrilobular, patchy ground-glass opacities (n = 3), diffuse ground-glass opacities (n = 2), ground-glass opacities with septal thickening (n = 1), and marked pleural effusion (n = 1). All cases died, except for one with suspected pulmonary toxoplasmosis who was diagnosed by a polymerase chain reaction assay 2 days after the onset of symptoms. In pulmonary toxoplasmosis, CT findings are non-specific and may mimic pulmonary congestion, atypical pneumonia, viral pneumonitis, and bronchopneumonia. Early diagnosis and treatment is crucial for overcoming this serious infectious complication. Pulmonary toxoplasmosis should be considered during differential diagnosis in a recipient with otherwise unexplained signs of infection and CT findings with ground-glass opacities, regardless of the distribution.

  16. Diffuse micronodular pattern of bronchiolitis obliterans organizing pneumonia: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Lee, In Jae; Jang, Seung Hun; Min, Kwang Seon; Whang, Im Kyung; Lee, Yul; Bae, Sang Hoon [Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang (Korea, Republic of)

    2006-10-15

    The typical radiographic findings of bronchiolitis obliterans organizing pneumonia (BOOP) are known to be patchy air-space consolidation that is often subpleural, and with or without ground-glass opacities. However, there are scant radiologic reports about the micronodular pattern of BOOP. We report here on a case of BOOP that manifested as diffusely scattered ill-defined centrilobular micronodules on HRCT.

  17. Metastatic pulmonary calcification: high-resolution computed tomography findings in 23 cases

    International Nuclear Information System (INIS)

    Belem, Luciana Camara; Souza, Carolina A.; Souza Junior, Arthur Soares; Escuissato, Dante Luiz; Hochhegger, Bruno; Nobre, Luiz Felipe; Rodrigues, Rosana Souza; Gomes, Antonio Carlos Portugal; Silva, Claudio S.; Guimaraes, Marcos Duarte; Zanetti, Glaucia; Marchiori, Edson; Ottawa Hospital Research Institute, University of Ottawa,; Faculdade de Medicina de Sao Jose do Rio Preto; Ultra X, Sao Jose do Rio Preto, SP; Universidade Federal do Parana; Universidade Federal de Ciencias da Saude de Porto Alegre; Universidade Federal de Santa Catarina

    2017-01-01

    Objective: The aim of this study was to evaluate the high-resolution computed tomography (HRCT) findings in patients diagnosed with metastatic pulmonary calcification (MPC). Materials and Methods: We retrospectively reviewed the HRCT findings from 23 cases of MPC [14 men, 9 women; mean age, 54.3 (range, 26-89) years]. The patients were examined between 2000 and 2014 in nine tertiary hospitals in Brazil, Chile, and Canada. Diagnoses were established by histopathologic study in 18 patients and clinical-radiological correlation in 5 patients. Two chest radiologists analyzed the images and reached decisions by consensus. Results: The predominant HRCT findings were centrilobular ground-glass nodules (n = 14; 60.9%), consolidation with high attenuation (n = 10; 43.5%), small dense nodules (n = 9; 39.1%), peripheral reticular opacities associated with small calcified nodules (n = 5; 21.7%), and ground-glass opacities without centrilobular ground-glass nodular opacity (n = 5; 21.7%). Vascular calcification within the chest wall was found in four cases and pleural effusion was observed in five cases. The abnormalities were bilateral in 21 cases. Conclusion: MPC manifested with three main patterns on HRCT, most commonly centrilobular ground-glass nodules, often containing calcifications, followed by dense consolidation and small solid nodules, most of which were calcified. We also described another pattern of peripheral reticular opacities associated with small calcified nodules. These findings should suggest the diagnosis of MPC in the setting of hypercalcemia. (author)

  18. Translucent Procedures, Abstraction without Opacity

    Science.gov (United States)

    1993-10-01

    Justi1ficatilon By- Distribut •c._/ rAviiii andi or Dist Sp• ialI I ..da A Guillermo Rozas Mazo (1931-1990). c~uyo desco de dar a sus hijos la cducaci6n... que dI no pudo recibir. con este trabajo realizo. Lo proinetido es deuda. Acknowledgments There are many people to whom I owe my sanity and to whom I...constant value). This expression gives us the value of the last unknown. 4. Once the residual system is solved, compute the value of the eliminated un

  19. Intelligent Recognition of Lung Nodule Combining Rule-based and C-SVM Classifiers

    Directory of Open Access Journals (Sweden)

    Bin Li

    2011-10-01

    Full Text Available Computer-aided detection(CAD system for lung nodules plays the important role in the diagnosis of lung cancer. In this paper, an improved intelligent recognition method of lung nodule in HRCT combing rule-based and costsensitive support vector machine(C-SVM classifiers is proposed for detecting both solid nodules and ground-glass opacity(GGO nodules(part solid and nonsolid. This method consists of several steps. Firstly, segmentation of regions of interest(ROIs, including pulmonary parenchyma and lung nodule candidates, is a difficult task. On one side, the presence of noise lowers the visibility of low-contrast objects. On the other side, different types of nodules, including small nodules, nodules connecting to vasculature or other structures, part-solid or nonsolid nodules, are complex, noisy, weak edge or difficult to define the boundary. In order to overcome the difficulties of obvious boundary-leak and slow evolvement speed problem in segmentatioin of weak edge, an overall segmentation method is proposed, they are: the lung parenchyma is extracted based on threshold and morphologic segmentation method; the image denoising and enhancing is realized by nonlinear anisotropic diffusion filtering(NADF method;candidate pulmonary nodules are segmented by the improved C-V level set method, in which the segmentation result of EM-based fuzzy threshold method is used as the initial contour of active contour model and a constrained energy term is added into the PDE of level set function. Then, lung nodules are classified by using the intelligent classifiers combining rules and C-SVM. Rule-based classification is first used to remove easily dismissible nonnodule objects, then C-SVM classification are used to further classify nodule candidates and reduce the number of false positive(FP objects. In order to increase the efficiency of SVM, an improved training method is used to train SVM, which uses the grid search method to search the optimal parameters

  20. Intelligent Recognition of Lung Nodule Combining Rule-based and C-SVM Classifiers

    Directory of Open Access Journals (Sweden)

    Bin Li

    2012-02-01

    Full Text Available Computer-aided detection(CAD system for lung nodules plays the important role in the diagnosis of lung cancer. In this paper, an improved intelligent recognition method of lung nodule in HRCT combing rule-based and cost-sensitive support vector machine(C-SVM classifiers is proposed for detecting both solid nodules and ground-glass opacity(GGO nodules(part solid and nonsolid. This method consists of several steps. Firstly, segmentation of regions of interest(ROIs, including pulmonary parenchyma and lung nodule candidates, is a difficult task. On one side, the presence of noise lowers the visibility of low-contrast objects. On the other side, different types of nodules, including small nodules, nodules connecting to vasculature or other structures, part-solid or nonsolid nodules, are complex, noisy, weak edge or difficult to define the boundary. In order to overcome the difficulties of obvious boundary-leak and slow evolvement speed problem in segmentatioin of weak edge, an overall segmentation method is proposed, they are: the lung parenchyma is extracted based on threshold and morphologic segmentation method; the image denoising and enhancing is realized by nonlinear anisotropic diffusion filtering(NADF method; candidate pulmonary nodules are segmented by the improved C-V level set method, in which the segmentation result of EM-based fuzzy threshold method is used as the initial contour of active contour model and a constrained energy term is added into the PDE of level set function. Then, lung nodules are classified by using the intelligent classifiers combining rules and C-SVM. Rule-based classification is first used to remove easily dismissible nonnodule objects, then C-SVM classification are used to further classify nodule candidates and reduce the number of false positive(FP objects. In order to increase the efficiency of SVM, an improved training method is used to train SVM, which uses the grid search method to search the optimal

  1. Usual interstitial pneumonia and non-specific interstitial pneumonia: serial thin-section CT findings correlated with pulmonary function

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Yeon Joo; Lee, Kyung Soo; Chung, Man Pyo; Chung Myung Jin; Han, Joung Ho [Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Mueller, Nestor L. [University of British Columbia, Vancouver (Canada); Colby, Thomas V. [Mayo Clinic Scottsdale, Scottsdale (United States); Kim, Seon Woo [Samsung Medical Center, Seoul (Korea, Republic of)

    2005-09-15

    We wanted to demonstrate and compare the serial high-resolution CTs (HRCT) and the pulmonary function test (PFT) findings of the usual interstitial pneumonia (UIP) and the non-specific interstitial pneumonia (NSIP). The serial HRCT scans and the PFT results were retrospectively analysed and compared for 35 patients having UIP without significant honeycombing (UIP-w/o hc, < 5% of honeycombing at CT), 35 patients having UIP with honeycombing (UIP-w/i hc, {>=} 5% of honeycombing), and 25 patients with NSIP. The mortality rates were also compared. Follow-up CT scans were available in 75 patients (29 UIP-w/o hc patients, 22 UIP-w/i hc patients and 24 NSIP patients) and the follow-up periods ranged from 150 to 2,370 days. The initial and follow-up PFT data were available for 71 patients. On the initial CT, significant differences were present between the UIP-w/i hc patients and both the UIP-w/o hc patients and the NSIP patients in the overall extent, ground-glass opacity (GGO) away from the reticulation, reticulation and honeycombing (all {rho} < 0.05). Improvement was noticed in five (17%) of 29 UIP-w/o hc patients, none of 22 UIP-w/i hc patients, and 9 (37%) of 24 NSIP patients; deterioration was noted in six (21%) UIP-w/o hc patients, two (9%) UIP-w/i hc patients and three (13%) NSIP patients ({rho} 0.044 between UIP-w/o and UIP-w/i hc; {rho} = 0.637 between UIP-w/o hc and NSIP; {rho} = 0.007 between UIP-w/i hc and NSIP). The serial changes of the pulmonary function in the NSIP patients were different from those noted for the UIP-w/i hc and UIP-w/o hc patients ({rho} = 0.440 between UIP-w/o and UIP-w/i hc; {rho} = 0.022 between UIP-w/o hc and NSIP; {rho} =0.003 between UIP-w/i hc and NSIP). Five (14%) of the 35 patients with UIP-w/o hc, 16 (46%) of the 35 patients with UIP-w/i hc and three (12%) of the 25 patients with NSIP died ({rho} = 0.002, comparison for the three groups). On CT, NSIP and UIP-w/o hc patients have similar patterns of parenchymal abnormalities and

  2. Comparison of chest-CT findings of Influenza virus-associated pneumonia in immunocompetent vs. immunocompromised patients

    Energy Technology Data Exchange (ETDEWEB)

    Kloth, C., E-mail: christopher.kloth@med.uni-tuebingen.de [Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Hoppe-Seyler-Str. 3, 72076 Tübingen (Germany); Forler, S.; Gatidis, S. [Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Hoppe-Seyler-Str. 3, 72076 Tübingen (Germany); Beck, R. [Institute of Medical Virology and Epidemiology of Viral Diseases, Eberhard-Karls-University, Elfriede-Aulhorn-Straße 6, 72076 Tübingen (Germany); Spira, D.; Nikolaou, K.; Horger, M. [Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Hoppe-Seyler-Str. 3, 72076 Tübingen (Germany)

    2015-06-15

    Highlights: • Patterns of pulmonary infiltration caused by Influenza viruses do not significantly differ between immunocompetent and immunocompromised patients or between different types and subtypes of Influenza virus. • Patterns of pulmonary infiltration caused by Influenza viruses seem to be interchangeable which might in part explain the great overlap in CT-imaging findings that has been reported in the past. • Interestingly, pattern transition from interstitial into airway-centric pattern seems to be frequent in immunocompromised patients receiving specific antiviral therapy, whereas the conversion of the airway-centric pattern into an interstitial pattern was observed more frequent in immunocompetent patients developing ARDS. - Abstract: Purpose: To retrospectively compare CT-patterns of pulmonary infiltration caused by different Influenza virus types and subtypes in immunocompetent and immunocompromised patients for possible discrimination. Materials and methods: Retrospective database search at our institution yielded 237 patients who were tested positive for Influenza virus type A or type B by bronchoalveolar lavage between January 2009 and April 2014. Fifty-six of these patients (female 26; male 30; median age 55.8 y, range 17–86 y; SD ± 14.4 y) underwent chest-HRCT due to a more severe clinical course of pulmonary infection. We registered all CT-findings compatible with pulmonary infection classifying them as airway predominant (tree-in-bud, centrilobular nodules, bronchial wall thickening ± peribronchial ground-glass opacity and consolidation) vs. interstitial-parenchymal predominant (bilateral, symmetrical GGO, consolidation, crazy paving and/or interlobular septal thickening). Twenty-six patients (46.4%) had follow-up CT-studies (0.78 mean, SD ± 5.8 scans). Results: Thirty-six patients were immunocompromised (group I) whereas 20 patients were immunocompetent (group II). An airway-centric pattern of infection was found in 15 patients (group

  3. Disease progression in usual interstitial pneumonia compared with desquamative interstitial pneumonia. Assessment with serial CT

    International Nuclear Information System (INIS)

    Hartman, T.E.; Primack, S.L.; Kang, E.Y.

    1997-01-01

    Objective. To determine the outcome of areas of ground-glass attenuation and assess disease progression on serial high-resolution CT (HRCT) scans of patients with biopsy specimen-proved usual interstitial pneumonia (UIP) and desquamative interstitial pneumonia (DIP). Materials and methods. Twelve patients with biopsy specimen-proved UIP and 11 patients with biopsy specimen-proved DIP who had initial and follow-up HRCT scans (median interval, 10 months) were reviewed. Eleven patients with UIP and 11 with DIP received treatment between the initial and follow-up CT scans. The scans were evaluated for the presence and extent of ground-glass attenuation, irregular linear opacities and honeycombing, and overall extent of parenchymal involvement. Results. On initial CT scans, all 12 patients with UIP had areas of ground-glass attenuation (mean±SD extent, 30±16%) and irregular lines (mean±SD extent, 17±7%) and 10 patients had honeycombing (mean±SD extent, 10±6%). All 11 patients with DIP had areas of ground-glass attenuation on initial HRCT scans (mean±SD extent, 51±26%), 5 patients had irregular linear opacities (mean±SD extent, 5±5%), and 1 patient had honeycombing. Nine of the 12 patients with UIP showed increase in the extent of ground-glass attenuation (n=6) or progression to irregular lines (n=2) or honeycombing (n=4) on follow-up as compared with only 2 patients with DIP who showed progression to irregular lines (n=1) or honeycombing (n=1) (p 2 test). Conclusion. In patients with UIP, areas of ground-glass attenuation usually increase in extent or progress to fibrosis despite treatment. Areas of ground-glass attenuation in most patients with DIP remain stable or improve with treatment. (authors)

  4. Chest CT scans are frequently abnormal in asymptomatic patients with newly diagnosed acute myeloid leukemia.

    Science.gov (United States)

    Vallipuram, Janaki; Dhalla, Sidika; Bell, Chaim M; Dresser, Linda; Han, Heekyung; Husain, Shahid; Minden, Mark D; Paul, Narinder S; So, Miranda; Steinberg, Marilyn; Vallipuram, Mayuran; Wong, Gary; Morris, Andrew M

    2017-04-01

    Chest computed tomography (CT) findings of nodules, ground glass opacities, and consolidations are often interpreted as representing invasive fungal infection in individuals with febrile neutropenia. We assessed whether these CT findings were present in asymptomatic individuals with acute myeloid leukemia (AML) at low risk of invasive fungal disease. A retrospective study of consecutive asymptomatic adult patients with newly diagnosed AML over a 2-year period was performed at a tertiary care oncology center. Radiology reports of baseline chest CTs were reviewed. Of 145 CT scans, the majority (88%) had pulmonary abnormalities. Many (70%) had one or both of unspecified opacities (52%) and nodules (49%). Ground glass opacities (18%) and consolidations (12%) occurred less frequently. Radiologists suggested pneumonia as a possible diagnosis in 32% (n = 47) of scans. Chest CT may result in over-diagnosis of invasive fungal disease in individuals with febrile neutropenia if interpreted without correlation to the patients' clinical status.

  5. Miliary tuberculosis: HRCT findings in 14 patients

    International Nuclear Information System (INIS)

    Son, Hyun Ju; Kim, Kun II; Juhng, Dong Hi; Lee, Suk Hong; Kim, Byung Su; Park, Soon Kew

    1994-01-01

    To evaluate high-resolution CT(HRCT) findings of the miliary tuberculosis and their significance. We retrospectively studied clinical records, HRCT and chest radiographs of 14 patients with miliary tuberculosis. On HRCT, nodules were seen in all 14 cases, 10 of them evenly, and 4 were irregularly distributed. The size of each nodule was less than 1 mm in 7 cases, 1 - 2 mm in 6 cases, and 3 mm or more in 1 case. The ground - glass opacity was accompanied in 8 cases, and fine reticular opacity was also noted in 8 cases. Other associated findings were pleural effusion (n=4), hilar and mediastinal lymphadenopathy (n=3), consolidation of the exudative tuberculosis (n=4). HRCT findings of miliary tuberculosis are diffusely distributed micro nodules of variable size, less than 5 mm in diameter. The ground-glass opacity can be combined

  6. High-resolution CT of lymphoid interstitial pneumonia

    International Nuclear Information System (INIS)

    Vilgrain, V.; Frija, J.; Yana, C.; Couderc, L.J.; David, M.; Clauvel, J.P.; Laval-Jeantet, M.

    1989-01-01

    Three patients with lymphoid interstitial pneumonia (two HIV 1+ patients with chronic lymphadenopathic syndromes and one with a not-characterized autoimmune disease) have been studied with high-resolution computed tomography (HR-CT). This technique reveals septal lines, small reticulonodular opacities, polyhedral micronodular opacities, 'ground-glass' opacities and a dense, subpleural, curved broken line in one patient. The lesions dominate in the bases of the lungs. They are not characteristic for lymphoid interstitial pneumonia. If a patient presents with a chronic lymphadenopathic syndrome, the diagnosis of an opportunistic infection should not be automatically made, since the syndrome can be caused by lymphoid interstitial pneumonia [fr

  7. Fabrication and evaluation of hybrid materials from A-zeolite and ground glass powders for vitrified radioactive waste

    International Nuclear Information System (INIS)

    Kamitani, Masataka; Kondo, Mitsunori; Hiki, Tomonori; Tagami, Toru; Nakahira, Atsushi; Wakihara, Toru

    2014-01-01

    The samples from A-type zeolite and ground soda-lime glass powders were solidified by calcinations at 600 to 800°C in air atmosphere. These hybrid zeolite/glass samples at 700°C were in part insufficiently densified and hybrid samples were fully densified at 800°C, although the densification was not generated at 600°C. A-zeolites were still stable in glass melt at 800°C for hybrid zeolite/glass samples. These hybrid zeolite/glass samples had the ion exchange ability of 20% against Sr 2+ and the high ability over 80% against Cs + as well as A-zeolite. Microstructures of obtained hybrid zeolite/glass samples were evaluated. (author)

  8. High ion-exchange properties of hybrid materials from X-type zeolite and ground glass powder

    Science.gov (United States)

    Taira, Nobuyuki; Yoshida, Kohei

    2017-10-01

    Zeolites are crystalline aluminosilicates with a homogeneous distribution of micropores with a superior cation-exchange capacity. Because they have especially excellent selective exchange properties, a considerable number of studies have been conducted on treating water containing radioisotopes using the zeolites. When using artificial zeolites, they have inferior sinterability; in addition, it is quite hard for them to remove from polluted liquid since these artificial zeolites are principally synthesized as a form of powder, which is a disadvantage. In this study, hybrid materials were prepared from X-type zeolite and waste glass powder. Their ion-removal effect and mechanical strength were investigated. The zeolite and waste glass were ground in an agate mortar in several ratios. 0.5 g of the mixture was pressure-molded into pellets having a diameter of 7 mm. These pellets were slowly heated at the speed of 240°C/h to 700°C and maintained at 700°C for 2 h. The removal rate of Sr2+ ions increased as the amount of X-type zeolite in the hybrid materials increased; the former increased up to 100% when the content of latter exceeded 50%. The mechanical strength increased by increasing the amount of glass in the hybrid materials. This is attributed to the fact that the glass powder acts as a binder that improves the densification and consequently the mechanical strength of the hybrid materials.

  9. Evaluation of CT findings in patients with adult respiratory distress syndrome in intensive care unit

    International Nuclear Information System (INIS)

    Honda, Ryoichi; Yoshida, Kazuhiro; Sato, Morihito; Yoshida, Masashi; Ura, Nobuyuki; Kaneko, Masamitsu

    1996-01-01

    Computed tomographic (CT) findings of 19 critically ill patients with adult respiratory distress syndrome (ARDS) in ICU were analyzed retrospectively. ARDS was diagnosed according to Murray's criteria (Lung Injury Score> 2.5). The CT findings obtained were diffuse increased lung opacities [100%] (ground-glass opacity [100%] and air-space consolidation [74%]), lobular distributions of increased opacity [53%], loss of lung volume [53%], bronchiectasis and bronchioloectasis [42%] , fine reticular opacity [26%] and peribronchovascular distributions of increased density [11%]. Among those findings, diffuse increased lung opacities were seen in almost all patients. Especially ground-glass opacity was seen in all patients and distributed in the whole lung. Air-space consolidation was observed in 14 patients and involved mainly lower lung fields. Loss of lung volume and bronchiectasis and bronchioloectasis were likely to exist in the same area of air-space consolidation. Lobular distributions of increased opacity was seen in 10 patients without specific distribution. Those findings were thought to be relatively specific CT findings of ARDS. It is concluded that CT findings provide more information than bedside plain roentgenograms and was useful for clinical management of patients with ARDS. (author)

  10. Paraquat induced lung injury: long-term follow-up of HRCT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Tong; Kim, Hyun Cheol; Bae, Won Kyung; Kim, Il Young; Im, Han Hyek [Soonchunhyang Univ., Chunan (Korea, Republic of)

    2004-03-01

    To determine the long-term follow-up CT findings of paraquat-induced lung injury. Six patients who ingested paraquat underwent sequential follow-up CT scanning during a period of at least six months, and the results were analysed. Scans were obtained 1-6 (mean, 3.3) time during a 7-84 (mean, 25.7) months period, and the findings at 1-2 months, 3-12 months, 1-2 years, 2-3 years and more than above 7 years after poisoning were analyzed. We observed irregular-shaped areas of consolidation with traction bronchiectasis at 1-2 months (5/5), irregular-shaped consolidation and ground-glass opacity (5/5) at 3-12 months, and irregular-shaped consolidations/ground-glass opacity (4/5) and focal honeycombing (1/5) one year later. In the same patients, follow-up CT scans showed that some areas of focal consolidation could not be visualized and the radio-opacity of the lesions had decreased. The HRCT findings of paraquat-induced lung injury were irregular shaped areas of consolidation 1-2 months after ingestion, and irregular-shaped consolidation and ground-glass opacity or focal honeycombing 3-12 months later. At this thim slight improvement was observed.

  11. High-resolution computed tomographic findings of Aspergillus infection in lung transplant patients

    International Nuclear Information System (INIS)

    Gazzoni, Fernando Ferreira; Hochhegger, Bruno; Severo, Luiz Carlos; Marchiori, Edson; Pasqualotto, Alessandro; Sartori, Ana Paula Garcia; Schio, Sadi; Camargo, José

    2014-01-01

    Objective: The aim of this study was to assess high-resolution computed tomographic (HRCT) findings at presentation in lung transplant patients diagnosed with pulmonary Aspergillus infection. Materials and methods: We retrospectively reviewed HRCT findings from 23 patients diagnosed with pulmonary aspergillosis. Imaging studies were performed 2–5 days after the onset of symptoms. The patient sample comprised 12 men and 11 women aged 22–59 years (mean age, 43.6 years). All patients had dyspnea, tachypnea, and cough. Diagnoses were established with Platelia Aspergillus enzyme immunoassays for galactomannan antigen detection in bronchoalveolar lavage and recovery of symptoms, and HRCT findings after voriconazole treatment. The HRCT scans were reviewed independently by two observers who reached a consensus decision. Results: The main HRCT pattern, found in 65% (n = 15) of patients, was centrilobular tree-in-bud nodules associated with bronchial thickening. This pattern was described in association with areas of consolidation and ground-glass opacities in 13% (n = 3) of patients. Consolidation and ground-glass opacities were the main pattern in 22% (n = 5) of patients. The pattern of large nodules with and without the halo sign was observed in 13% (n = 3) of patients, and were associated with consolidation and ground-glass opacities in one case. Conclusion: The predominant HRCT findings in lung transplant patients with pulmonary aspergillosis were bilateral bronchial wall thickening and centrilobular opacities with the tree-in-bud pattern. Ground-glass opacities and/or bilateral areas of consolidation were also common findings. Pulmonary nodules with the halo sign were found in only 13% of patients

  12. Aplicación de dos nuevos algoritmos para agrupar resultados de búsquedas en sistemas de catálogos públicos en línea (OPAC

    Directory of Open Access Journals (Sweden)

    Andrés Marín

    2008-01-01

    Full Text Available Con la facilidad que da la Internet y, en particular la Web, cada día es más fácil acceder a nuevas fuentesde información puestas a disposición en cualquier lugar del mundo. Los usuarios buscan informaciónespecífica de acuerdo a sus necesidades particulares, a través de la Web. Ellos pueden hacer búsquedasya sea mediante motores de búsqueda tales como Google o Yahoo!, o también mediante bases de datosparticulares de bibliotecas o sistemas de información. Sin embargo, los resultados de consultas enmotores de búsqueda, sistemas de catálogos de acceso público en línea, y en general sistemas deconsulta en la Web, pueden saturar a un usuario por la abundancia de resultados, causando pérdida deefectividad del sistema de búsqueda. Para resolver este problema, la investigación "Agrupamiento deresultados obtenidos de consultas distribuidas en sistemas de catálogos públicos en línea (OPAC",de la que se deriva este artículo, propone dos algoritmos de agrupamiento de resultados orientados asistemas en línea concurrentes, con características de bajo consumo de ciclos de procesador y memoria,los cuales se usan en un prototipo de software.

  13. Comparative analysis of the nuclear lens opalescence by the Lens Opacities Classification System III with nuclear density values provided by Oculus Pentacam: a cross-section study using Pentacam Nucleus Staging software.

    Science.gov (United States)

    Magalhães, Fernanda Pedreira; Costa, Elaine Fiod; Cariello, Angelino Júlio; Rodrigues, Eduardo Buchele; Hofling-Lima, Ana Luisa

    2011-01-01

    To compare the clinical classification of cataract using the Lens Opacities Classification System (LOCS) III with the mean values of lens density provided by the Pentacam Scheimpflug System in nuclear cataracts. One hundred and one eyes from 101 patients with age-related nuclear cataract were submitted to clinical examination for lens grading score using LOCS III. According to LOCS III, nuclear opalescence was divided in six groups. Patients were evaluated by the Pentacam Scheimpflug System for the mean lens density using the Pentacam lens densitometry program (PLDP), the Pentacam Nucleus Staging (PNS) mean value and the PNS cataract grading score. A positive correlation between the mean values of lens density and LOCS III classification, considering groups 1 to 5, could be noticed with PLDP and PNS mean value. The mean values between the groups were similar using the PLDP and the PNS mean value. However, when the PNS cataract grading score was evaluated, there was low correspondence with LOCS III classification. Pentacam Scheimpflug device offers an objective measure of the lens nuclear density on nuclear cataracts. PLDP and the PNS mean value were both useful to evaluate age-related nuclear cataract up to LOCS III group 5.

  14. Comparative analysis of the nuclear lens opalescence by the Lens Opacities Classification System III with nuclear density values provided by Oculus Pentacam: a cross-section study using Pentacam Nucleus Staging software

    Directory of Open Access Journals (Sweden)

    Fernanda Pedreira Magalhães

    2011-04-01

    Full Text Available PURPOSE: To compare the clinical classification of cataract using the Lens Opacities Classification System (LOCS III with the mean values of lens density provided by the Pentacam Scheimpflug System in nuclear cataracts. METHODS: One hundred and one eyes from 101 patients with age-related nuclear cataract were submitted to clinical examination for lens grading score using LOCS III. According to LOCS III, nuclear opalescence was divided in six groups. Patients were evaluated by the Pentacam Scheimpflug System for the mean lens density using the Pentacam lens densitometry program (PLDP, the Pentacam Nucleus Staging (PNS mean value and the PNS cataract grading score. RESULTS: A positive correlation between the mean values of lens density and LOCS III classification, considering groups 1 to 5, could be noticed with PLDP and PNS mean value. The mean values between the groups were similar using the PLDP and the PNS mean value. However, when the PNS cataract grading score was evaluated, there was low correspondence with LOCS III classification. CONCLUSION: Pentacam Scheimpflug device offers an objective measure of the lens nuclear density on nuclear cataracts. PLDP and the PNS mean value were both useful to evaluate age-related nuclear cataract up to LOCS III group 5.

  15. Middle east respiratory syndrome-corona virus infection: A case report of sieral computed tomographic findings in a young male patient

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Won Jin; Lee, Ki Nam; Kang, Eun Ju; Lee, Hyuck [Dong A University Hospital, Busan (Korea, Republic of)

    2016-02-15

    Radiologic findings of Middle East respiratory syndrome (MERS), a novel coronavirus infection, have been rarely reported. We report a 30-year-old male presented with fever, abdominal pain, and diarrhea, who was diagnosed with MERS. A chest computed tomographic scan revealed rapidly developed multifocal nodular consolidations with ground-glass opacity halo and mixed consolidation, mainly in the dependent and peripheral areas. After treatment, follow-up imaging showed that these abnormalities markedly decreased but fibrotic changes developed.

  16. A case of vildagliptin-induced interstitial pneumonia

    OpenAIRE

    Kuse, Naoyuki; Abe, Shinji; Kuribayashi, Hidehiko; Inomata, Minoru; Saito, Hitoshi; Fukuda, Yuh; Gemma, Akihiko

    2016-01-01

    A 65-year-old Japanese male with type 2 diabetes mellitus was admitted to our hospital with a productive cough and worsening dyspnea. He had started receiving vildagliptin, which is one of the dipeptideylpeptidase-4 (DPP-4) inhibitors, several days before the appearance of his symptoms. Laboratory findings revealed markedly elevated levels of immunoglobulin E and Krebs von den Lungen-6. Chest computed tomography revealed ground-glass opacity with irregular reticulation throughout both lungs. ...

  17. Pulmonary hemosiderosis due to mitral valvular heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eung Yeop; Kim, Tae Sung; Han, Joung Ho; Lee, Kyung Soo [Sungkyunkwan Univ. College of Medicine, Seoul (Korea, Republic of)

    1999-01-01

    We report a case of biopsy-proven secondary hemosiderosis of the lung in a 58-year-old patient with mitral valvular heart disease. Both chest radiography and high-resolution CT demonstrated patchy areas of ground-glass opacity ; the former indicated that it was in both lungs, while the latter showed inter-and intralobular septal thickening. These findings were reversible when pulmonary venous hypertension was corrected.

  18. Pulmonary hemosiderosis due to mitral valvular heart disease

    International Nuclear Information System (INIS)

    Kim, Eung Yeop; Kim, Tae Sung; Han, Joung Ho; Lee, Kyung Soo

    1999-01-01

    We report a case of biopsy-proven secondary hemosiderosis of the lung in a 58-year-old patient with mitral valvular heart disease. Both chest radiography and high-resolution CT demonstrated patchy areas of ground-glass opacity ; the former indicated that it was in both lungs, while the latter showed inter-and intralobular septal thickening. These findings were reversible when pulmonary venous hypertension was corrected

  19. Pneumonia in novel swine-origin influenza A (H1N1) virus infection: High-resolution CT findings

    International Nuclear Information System (INIS)

    Li Ping; Su Dongju; Zhang Jifeng; Xia Xudong; Sui Hong; Zhao Donghui

    2011-01-01

    Objective: The purpose of our study was to review the initial high-resolution CT (HRCT) findings in pneumonia patients with presumed/laboratory-confirmed novel swine-origin influenza A (H1N1) virus (S-OIV) infection and detect pneumonia earlier. Materials and methods: High-resolution CT (HRCT) findings of 106 patients with presumed/laboratory-confirmed novel S-OIV (H1N1) infection were reviewed. The 106 patients were divided into two groups according to the serious condition of the diseases. The pattern (consolidation, ground-glass, nodules, and reticulation), distribution, and extent of abnormality on the HRCT were evaluated in both groups. The dates of the onset of symptoms of the patients were recorded. Results: The predominant CT findings in the patients at presentation were unilateral or bilateral multifocal asymmetric ground-glass opacities alone (n = 29, 27.4%), with unilateral or bilateral consolidation (n = 50, 47.2%). The consolidation had peribronchovascular and subpleural predominance. The areas of consolidation were found mainly in the posterior, middle and lower regions of the lungs. Reticular opacities were found in 6 cases of the initial MDCT scan. The extent of disease was greater in group 1 patients requiring advanced mechanical ventilation, with diffuse involvement in 19 patients (63.3%) of group 1 patients, and only 15/76 (19.7%) of group 2 patients (p 2 test). 20 cases (19%) of the 106 patients had small bilateral or unilateral pleural effusions. None had evidence of hilar or mediastinal lymph node enlargement on CT performed at admission or later. Conclusions: The most common radiographic and CT findings in patients with S-OIV infection are unilateral or bilateral ground-glass opacities with or without associated focal or multifocal areas of consolidation. On HRCT, the ground-glass opacities had a predominant peribronchovascular and subpleural distribution. CT plays an important role in the early recognition of severe S-OIV (H1N1).

  20. Radiologic Findings of Influenza A (H1N1) Pneumonia: Report of Two Cases

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Jin Kyoung; Ahn, Myeong Im; Jung, Jung Im; Han, Dae Hee; Park, Seog Hee; Park, Chan Kwon; Kim, Young Kyoon [Seoul St. Mary' s Hospital, Seoul (Korea, Republic of)

    2010-08-15

    Novel influenza A (H1N1) infection is a highly infectious disease, which has been rapidly spreading worldwide since it was first documented in March of 2009 in Mexico. We experienced and report two cases of Influenza A (H1N1) pneumonia, accompanied by chest radiographic and CT findings. The chest radiographs revealed diffuse haziness and extensive airspace consolidation, whereas the CT scans demonstrated multifocal areas of ground glass opacity and airspace consolidation with a CT halo sign.

  1. Imaging manifestation of A H1N1 influenza with pneumonia

    International Nuclear Information System (INIS)

    Yang Jun; Xu Yunliang; Lu Zhibin; Wang Xiaojie; Li Shuo; Du Lei; Guo Limin; Li Xingwang

    2010-01-01

    Objective: To evaluate the imaging features of pneumonia caused by A (H1N1) influenza virus. Methods: Imaging data of 51 patients with pneumonia caused by A H1N1 influenza were retrospectively reviewed. All patients underwent mobile chest radiographs and 44 patients underwent CT as well. On the basis of the lesion degree in the lung, the patients were classified into mild, moderate and serious types. Results: Mild type showed patchy consolidation at chest imaging in 4 patients. Moderate type demonstrated consolidation and (or) ground-glass opacities more than 2 lung fields in 33 patients, including 30 bilateral and 3 unilateral. Serious type displayed diffuse consolidation and ground-glass opacities, probably accompanying with interstitial lesions in the lungs in 14 patients, including 6 patients with ARDS, 2 with infection and 1 with cutaneous emphysema. Conclusion: The imaging features of pneumonia caused by A H1N1 influenza mainly manifest as consolidation and ground-glass opacities, probably accompanying with interstitial changes. The imaging findings show various in patients with infection. Some serious patients even develope to ARDS. (authors)

  2. Chronic mercury vapor poisoning of the lung plain radiography and high resolution CT

    Energy Technology Data Exchange (ETDEWEB)

    Park, Choong Ki; Hwang, Woo Cheol; Nho, Joon Young; Ahn, Bum Gyu; Woo, Hyo Cheol; Kim, Heung Cheol; Lee, Myoung Koo [Hallym University College of Medicine, Seoul (Korea, Republic of)

    1993-09-15

    Authors analyzed the findings of chest radiographs and high-resolution CT(HRCT) of the chronic mercury vapor poisoning in 12 patients who were diagnosed by previous working history for mercury-thermometer and high level of mercury in blood and urine. The purpose of this paper is to introduce the HRCT findings of chronic mercury vapor poisoning. Duration of mercury exposure was ranged from 10 to 41 months(mean, 21.8 months). Estimated value of serum mercury was ranged from 3.6 to 8.7 {mu} g/dl(mean, 5.3 {mu} g/dl: normal value is less than 0.5 {mu} g/dl). Estimated value of mercury in urine was ranged from 104 to 482 {mu} g/l(mean, 291.4 {mu} g/l; normal value is less than 20 {mu} g/l). Chest radiographs showed positive findings such as ground glass opacities and peribronchial cuffings in only 2 out of 12 patients, but HRCT showed positive findings such as ground glass opacities in 8 patients, peribronchial cuffings in 7 patients, centrilobular abnormalities in 5 patients, interface sign in 4 patients, interlobular septal thickening with intralobular lines in 2 patients and lobular consolidation in one patient. In conclusion, chest HRCT is superior to chest radiograph to show the pulmonary manifestation of chronic mercury vapor poisoning. In patients with chronic mercury vapor poisoning. HRCT findings of centrilobular distributed ground glass opacities and peribroncjial cuffinges are characteristic.

  3. Unusual Radiographic Presentation of Pneumocystis Pneumonia in a Patient with AIDS

    Directory of Open Access Journals (Sweden)

    Brian L. Block

    2017-01-01

    Full Text Available Pneumocystis jirovecii pneumonia (PCP typically presents as an interstitial and alveolar process with ground glass opacities on chest computed tomography (CT. The absence of ground glass opacities on chest CT is thought to have a high negative predictive value for PCP in individuals with AIDS. Here, we report a case of PCP in a man with AIDS who presented to our hospital with subacute shortness of breath and a nonproductive cough. While his chest CT revealed diffuse nodular rather than ground glass opacities, bronchoscopy with bronchoalveolar lavage and transbronchial biopsies confirmed the diagnosis of PCP and did not identify additional pathogens. PCP was not the expected diagnosis based on chest CT, but it otherwise fit well with the patient’s clinical and laboratory presentation. In the era of combination antiretroviral therapy, routine prophylaxis for PCP, and increased use of computed tomography, it may be that PCP will increasingly present with nonclassical chest radiographic patterns. Clinicians should be aware of this presentation when selecting diagnostic and management strategies.

  4. Air-space pattern in lung metastasis from adenocarcinoma of the GI tract

    Energy Technology Data Exchange (ETDEWEB)

    Gaeta, M.; Volta, S.; Scribano, E. [Univ. of Messina (Italy)] [and others

    1996-03-01

    We retrospectively reviewed a series of proven lung metastasis to evaluate the frequency and CT features of metastases showing an air-space (lepidic) pattern of growth. CT examinations of 65 patients with proven lung metastasis from GI carcinomas were reviewed by three observers. Four CT features were used to classify lesions as air-space metastases: (a) air-space nodules; (b) parenchymal consolidation containing air bronchogram and/or showing angiogram sign; (c) focal or extensive ground-glass opacities; and (d) nodule(s) with a {open_quotes}halo{close_quotes} sign. Six of 65 patients showed air-space metastases: three from pancreatic carcinoma. two from colonic carcinoma, and one from jejunal carcinoma. In one case, metastasis appeared as extensive parenchymal consolidation associated with ground-glass opacities; in one as an area of ground-glass opacity; in one as an extensive parenchymal consolidation with air bronchogram; in one as parenchymal consolidations with angiogram sign and multiple nodules, some of these with halo sign; in one as air-space nodules and patchy air-space consolidations; and in one as a solitary nodule with halo sign. Our study shows that air-space lung metastasis from GI carcinomas is uncommon but not rare. On CT as well as microscopically, differential diagnosis between air-space metastasis and bronchioloalveolar carcinoma may be impossible. 13 refs., 5 figs., 1 tab.

  5. Comparison of initial high resolution computed tomography features in viral pneumonia between metapneumovirus infection and severe acute respiratory syndrome

    International Nuclear Information System (INIS)

    Wong, Cheuk Kei Kathy; Lai, Vincent; Wong, Yiu Chung

    2012-01-01

    Objective: To review and compare initial high resolution computed tomography (HRCT) findings in patients with metapneumovirus pneumonia and severe acute respiratory syndrome (SARS-Coronovirus). Materials and methods: 4 cases of metapneumovirus pneumonia (mean age of 52.3 years) in an institutional outbreak (Castle Peak Hospital) in 2008 and 38 cases of SARS-coronovirus (mean age of 39.6 years) admitted to Tuen Mun hospital during an epidemic outbreak in 2003 were included. HRCT findings of the lungs for all patients were retrospectively reviewed by two independent radiologists. Results: In the metapneumovirus group, common HRCT features were ground glass opacities (100%), consolidation (100%), parenchymal band (100%), bronchiectasis (75%). Crazy paving pattern was absent. They were predominantly subpleural and basal in location and bilateral involvement was observed in 50% of patients. In the SARS group, common HRCT features were ground glass opacities (92.1%), interlobular septal thickening (86.8%), crazy paving pattern (73.7%) and consolidation (68%). Bronchiectasis was not seen. Majority of patient demonstrated segmental or lobar in distribution and bilateral involvement was observed in 44.7% of patients. Pleural effusion and lymphadenopathy were of consistent rare features in both groups. Conclusion: Ground glass opacities, interlobular septal thickening and consolidations were consistent HRCT manifestations in both metapneumovirus infection and SARS. The presence of bronchiectasis (0% in SARS) may point towards metapneumovirus while crazy paving pattern is more suggestive of SARS.

  6. Influenza A (H1N1) pneumonia: HRCT findings

    Energy Technology Data Exchange (ETDEWEB)

    Amorim, Viviane Brandao; Rodrigues, Rosana Souza; Barreto, Miriam Menna; Marchiori, Edson, E-mail: edmarchiori@gmail.com [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil); Zanetti, Glaucia [Escola de Medicina de Petropolis, RJ (Brazil); Hochhegger, Bruno [Santa Casa de Misericordia de Porto Alegre, RS (Brazil)

    2013-11-01

    Objective: to describe aspects found on HRCT scans of the chest in patients infected with the influenza A (H1N1) virus. Methods: we retrospectively analyzed the HRCT scans of 71 patients (38 females and 33 males) with H1N1 infection, confirmed through laboratory tests, between July and September of 2009. The HRCT scans were interpreted by two thoracic radiologists independently, and in case of disagreement, the decisions were made by consensus. Results: the most common HRCT findings were ground-glass opacities (85%), consolidation (64%), or a combination of ground-glass opacities and consolidation (58%). Other findings were airspace nodules (25%), bronchial wall thickening (25%), interlobular septal thickening (21%), crazy-paving pattern (15%), perilobular pattern (3%), and air trapping (3%). The findings were frequently bilateral (89%), with a random distribution (68%). Pleural effusion, when observed, was typically minimal. No lymphadenopathy was identified. Conclusions: the most common findings were ground-glass opacities and consolidations, or a combination of both. Involvement was commonly bilateral with no axial or cranio caudal predominance in the distribution. Although the major tomographic findings in H1N1 infection are nonspecific, it is important to recognize such findings in order to include infection with the H1N1 virus in the differential diagnosis of respiratory symptoms. (author)

  7. Chronic mercury vapor poisoning of the lung plain radiography and high resolution CT

    International Nuclear Information System (INIS)

    Park, Choong Ki; Hwang, Woo Cheol; Nho, Joon Young; Ahn, Bum Gyu; Woo, Hyo Cheol; Kim, Heung Cheol; Lee, Myoung Koo

    1993-01-01

    Authors analyzed the findings of chest radiographs and high-resolution CT(HRCT) of the chronic mercury vapor poisoning in 12 patients who were diagnosed by previous working history for mercury-thermometer and high level of mercury in blood and urine. The purpose of this paper is to introduce the HRCT findings of chronic mercury vapor poisoning. Duration of mercury exposure was ranged from 10 to 41 months(mean, 21.8 months). Estimated value of serum mercury was ranged from 3.6 to 8.7 μ g/dl(mean, 5.3 μ g/dl: normal value is less than 0.5 μ g/dl). Estimated value of mercury in urine was ranged from 104 to 482 μ g/l(mean, 291.4 μ g/l; normal value is less than 20 μ g/l). Chest radiographs showed positive findings such as ground glass opacities and peribronchial cuffings in only 2 out of 12 patients, but HRCT showed positive findings such as ground glass opacities in 8 patients, peribronchial cuffings in 7 patients, centrilobular abnormalities in 5 patients, interface sign in 4 patients, interlobular septal thickening with intralobular lines in 2 patients and lobular consolidation in one patient. In conclusion, chest HRCT is superior to chest radiograph to show the pulmonary manifestation of chronic mercury vapor poisoning. In patients with chronic mercury vapor poisoning. HRCT findings of centrilobular distributed ground glass opacities and peribroncjial cuffinges are characteristic

  8. Solitary nodular bronchioloalveolar carcinoma of the lung: prediction of histology at high-resolution CT

    International Nuclear Information System (INIS)

    Jang, Hyun Jung; Lee, Kyung Soo; Choo, In Wook; Kim, Seung Hoon; Lee, Won Jae; Byun, Hong Sik; Kim, Yoo Kyung; Shin, Myung Hee; Kim, Sang Jin

    1998-01-01

    The purpose of this study is to descdribe the characteristic high-resolution (HR) CT findings of solitary nodular bronchioloalveolar carcinoma (BAC) of the lung which are valuable for specific diagnosis of the disease. HRCT scans of 46 patients (31 with malignant and 15 with benign lesion) with a solitary pulmonary nodule seen on chest radiograph were distributed in random order and analyzed retrospectively. Two blinded observers jointly analyzed the marginal and internal characteristics of nodules as seen on HRCT, and decisions on the findings were reached by consensus. Stepwise discriminant analysis for characteristic findings of BAC was performed. The most frequent CT findings of BAC (n=3D15) were internal bubble lucency (14/15, 93%)(p=3D0.001), area of ground-glass opacity (12/15, 80%; average 58% of tumor volume)(p=3D0.0001), pleural tag(12/15, 80%; p=3D0.097), and lobulated and spiculated margin(8/15, 53%; p=3D0.459). Findings of ground-glass opacity (p=3D0.0001) and bubble lucency (p=3D0.0187) appeared to be discriminant in the diagnosis of BAC. Peripheral pulmonary nodules containing an area of ground-glass opacity associated with internal bubble-lucency are characteristic of BAC. Specific histologic diagnosis of solitary nodular BAC can be suggested by careful analysis of HRCT findings.=20

  9. Manifestations of infection by the novel influenza A (H1N1) virus at chest computed tomography

    International Nuclear Information System (INIS)

    Verrastro, Carlos Gustavo Yuji; D'Ippolito, Giuseppe

    2009-01-01

    Objective: the objective of this study was to describe chest computed tomography findings in confirmed cases of infection by the novel influenza A (H1N1) virus. Materials and methods: computed tomography studies of nine patients with laboratory-confirmed infection by the novel influenza A (H1N1) virus were consensually evaluated by three observers. The sample of the present study included five male and four female patients with ages ranging from 14 to 64 years (mean, 40 years). Four of the patients were previously healthy, four were kidney transplant recipients and one was pregnant at the time of diagnosis. Presence, extent and distribution of the following findings were evaluated: ground-glass opacities; centrilobular nodules; consolidation; interlobular septa thickening; pleural effusion; lymphadenopathy. Results: The most frequent findings were ground-glass opacities, centrilobular nodules and consolidations, present in nine (100%), five (55%) and four (44%) of cases, respectively. Pleural effusions and lymphadenopathy were less common findings, occurring in only two (22%) of the cases. Conclusion: ground-glass opacities, centrilobular nodules and consolidation were the most frequent findings in cases of infection by the novel influenza A (H1N1) virus. These changes are not typical or unique to this agent and may also occur in other viral or bacterial infections. (author)

  10. Organizing pneumonia: the many morphological faces

    International Nuclear Information System (INIS)

    Oikonomou, Anastasia; Hansell, David M.

    2002-01-01

    Organizing pneumonia is a non-specific response to various forms of lung injury and is the pathological hallmark of the distinct clinical entity termed cryptogenic organizing pneumonia. The typical imaging features of this syndrome have been widely documented and consist of patchy air-space consolidation, often subpleural, with or without ground-glass opacities. The purpose of this article is to highlight the less familiar imaging patterns of organizing pneumonia which include focal organizing pneumonia, a variety of nodular patterns, a bronchocentric distribution, band-like opacities, a perilobular pattern and a progressive fibrotic form of organizing pneumonia. (orig.)

  11. OPACs: The User and Subject Access.

    Science.gov (United States)

    Carson, Elizabeth

    1985-01-01

    This survey of the literature reveals user and professional opinions of changes in subject access features available for online public access catalogs. Highlights include expanded access to fields already incorporated into traditional MARC record, access to context of the record, and design of the user interface. Twenty-four references are cited.…

  12. Radiographic imaging study of pneumocystis carinii pneumonia in renal transplantation recipient

    International Nuclear Information System (INIS)

    Chen Chengshui; Li Yuping; Ye Min; Zhang Dongqing; Zheng Shaoling; Xing Lingling; Chen Shaoxian

    2005-01-01

    Objective: To improve the understanding of the imaging features of pneumocystis carinii pneumonia (PCP) in renal transplantation recipient. Methods: Twenty-four renal transplantation recipients suffered from PCP. There were 19 males and 5 females, the age ranged from 23 to 62 years (mean 39.2 years). The mean time duration from renal transplantation to onset of illness was 5.6 months, and the mean time from onset of illness to consultation was 5.5 days. All patients had fever and dyspnea. The chest radiographic imaging was reviewed and the dynamic imaging changes were followed up. Results: Pathology showed alveolar exudation, inflammation in the interstitium and alveolar lumen, fibrosis in lung interstitium, and erosion of alveolar epithelium. Initial chest X-ray demonstrated diffuse changes in only 10 patients. Of the 10 patients, 3 showed ground-glass changes, 2 showed ground-glass and reticular changes, and 4 showed consolidation. But all patients had abnormal ill-defined ground-glass findings on thoracic CT images, 9 of them showed reticulum among ground-glass changes, and 12 of them showed consolidation among ground-glass changes. Among patients with clinical deterioration, chest radiographs and CT showed progression of pulmonary infiltrations, and it reached the top level within 1 to 2 weeks. With successful response to therapy, chest radiographs and CT showed resolution of the lung opacities, but the resolution was retarded for about 1 week, complete resolution would need 4 weeks. Conclusion: The radiographic imaging features of PCP in renal transplantation recipient were diffuse interstitial alterations and consolidations, and with fast progression. With successful response to therapy, it showed resolution of the lung opacities, but the resolution was retarded for about 1 week, and complete resolution would need 4 weeks. Chest CT was more sensitive than radiographs. (authors)

  13. Post-mortem computed tomography findings of the lungs: Retrospective review and comparison with autopsy results of 30 infant cases

    Energy Technology Data Exchange (ETDEWEB)

    Kawasumi, Yusuke, E-mail: ssu@rad.med.tohoku.ac.jp [Tohoku University Graduate School of Medicine, Department of Clinical Imaging, 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8575 (Japan); Usui, Akihito, E-mail: t7402r0506@med.tohoku.ac.jp [Tohoku University Graduate School of Medicine, Department of Diagnostic Image Analysis, 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8575 (Japan); Hosokai, Yoshiyuki, E-mail: hosokai@med.tohoku.ac.jp [Tohoku University Graduate School of Medicine, Department of Diagnostic Image Analysis, 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8575 (Japan); Igari, Yui, E-mail: igari@forensic.med.tohoku.ac.jp [Tohoku University Graduate School of Medicine, Department of Forensic Medicine, 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8575 (Japan); Hosoya, Tadashi [Tohoku University Graduate School of Medicine, Department of Forensic Medicine, 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8575 (Japan); Hayashizaki, Yoshie, E-mail: yoshie@forensic.med.tohoku.ac.jp [Tohoku University Graduate School of Medicine, Department of Forensic Medicine, 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8575 (Japan); Saito, Haruo, E-mail: hsaito@med.tohoku.ac.jp [Tohoku University Graduate School of Medicine, Department of Diagnostic Image Analysis, 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8575 (Japan); Ishibashi, Tadashi, E-mail: tisibasi@med.tohoku.ac.jp [Tohoku University Graduate School of Medicine, Department of Clinical Imaging, 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8575 (Japan); Funayama, Masato, E-mail: funayama@forensic.med.tohoku.ac.jp [Tohoku University Graduate School of Medicine, Department of Forensic Medicine, 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8575 (Japan)

    2015-04-15

    Highlights: •Infant cases frequently show a diffuse increase in the concentration of lung fields on post-mortem computed tomography (PMCT). •In this study, twenty-two of the thirty sudden infant death cases showed increasing concentration in the entire lung field. •Based on the autopsy results, the lungs simply collapsed and no other abnormal lung findings were identified. •The radiologist should not consider increasing concentration in all lung fields as simply a pulmonary disorder when diagnosing the cause of infant death using PMCT. -- Abstract: Objectives: Infant cases frequently show a diffuse increase in the concentration of lung fields on post-mortem computed tomography (PMCT). However, the lungs often show simply atelectasis at autopsy in the absence of any other abnormal changes. Thus, we retrospectively reviewed the PMCT findings of lungs following sudden infant death and correlated them with the autopsy results. Materials and methods: We retrospectively reviewed infant cases (0 year) who had undergone PMCT and a forensic autopsy at our institution between May 2009 and June 2013. Lung opacities were classified according to their type; consolidation, ground-glass opacity and mixed, as well as distribution; bilateral diffuse and areas of sparing. Statistical analysis was performed to assess the relationships among lung opacities, causes of death and resuscitation attempt. Results: Thirty infant cases were selected, which included 22 sudden and unexplained deaths and 8 other causes of death. Resuscitation was attempted in 22 of 30 cases. Bilateral diffuse opacities were observed in 21 of the 30 cases. Of the 21 cases, 18 were sudden and unexplained deaths. Areas of sparing were observed in 4 sudden and unexplained deaths and 5 other causes of death. Distribution of opacities was not significantly associated with causes of death or resuscitation attempt. The 21 cases with bilateral diffuse opacities included 6 consolidations (4 sudden and unexplained

  14. Post-mortem computed tomography findings of the lungs: Retrospective review and comparison with autopsy results of 30 infant cases

    International Nuclear Information System (INIS)

    Kawasumi, Yusuke; Usui, Akihito; Hosokai, Yoshiyuki; Igari, Yui; Hosoya, Tadashi; Hayashizaki, Yoshie; Saito, Haruo; Ishibashi, Tadashi; Funayama, Masato

    2015-01-01

    Highlights: •Infant cases frequently show a diffuse increase in the concentration of lung fields on post-mortem computed tomography (PMCT). •In this study, twenty-two of the thirty sudden infant death cases showed increasing concentration in the entire lung field. •Based on the autopsy results, the lungs simply collapsed and no other abnormal lung findings were identified. •The radiologist should not consider increasing concentration in all lung fields as simply a pulmonary disorder when diagnosing the cause of infant death using PMCT. -- Abstract: Objectives: Infant cases frequently show a diffuse increase in the concentration of lung fields on post-mortem computed tomography (PMCT). However, the lungs often show simply atelectasis at autopsy in the absence of any other abnormal changes. Thus, we retrospectively reviewed the PMCT findings of lungs following sudden infant death and correlated them with the autopsy results. Materials and methods: We retrospectively reviewed infant cases (0 year) who had undergone PMCT and a forensic autopsy at our institution between May 2009 and June 2013. Lung opacities were classified according to their type; consolidation, ground-glass opacity and mixed, as well as distribution; bilateral diffuse and areas of sparing. Statistical analysis was performed to assess the relationships among lung opacities, causes of death and resuscitation attempt. Results: Thirty infant cases were selected, which included 22 sudden and unexplained deaths and 8 other causes of death. Resuscitation was attempted in 22 of 30 cases. Bilateral diffuse opacities were observed in 21 of the 30 cases. Of the 21 cases, 18 were sudden and unexplained deaths. Areas of sparing were observed in 4 sudden and unexplained deaths and 5 other causes of death. Distribution of opacities was not significantly associated with causes of death or resuscitation attempt. The 21 cases with bilateral diffuse opacities included 6 consolidations (4 sudden and unexplained

  15. Simple pulmonary eosinophilia (loeffler's syndrome): chest radiographic and CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Kyung Jae; Lee, Kyung Soo; Kim, Tae Sung; Chung, Man Pyo; Choi, Dong Chull; Kwon, O Jung [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2000-01-01

    The purpose of our study is to describe the chest radiographic and CT findings of simple pulmonary eosinophilia. Twenty-six patients with simple pulmonary eosinophilia underwent chest radiography and CT scanning; the results were analyzed retrospectively by two chest radiologists, focusing on the patterns and distribution of the parenchymal abnormalities. The chest radiographs were normal in eight patients (31%), while among the remaining 18 patients, they showed subtle opacity (n=3D9), nodules (n=3D8), consolidation (n=3D2), and mass (n=3D1). Follow-up chest radiographs (m=3D18) demonstrated complete (n=3D16) or partial (n=3D1) resolution of parenchymal lesions or migratory lesions (n=3D1). On CT, nodule(s) (n=3D19) were most commonly seen, followed by ground-glass opacity (n=3D16), consolidation (n=3D3), and mass (n=3D1). A peripheral halo surrounding a nodule or an area of consolidation was seen in 18 patients. The nodules(s) (n=3D19) were subpleural (n=3D13) or random (=3D6). Areas of ground-glass opacity (n=3D16) were subpleural (n=3D13), random (n=3D2), or central (n=3D1). All lesions were patchy rather than diffuse. Follow-up CT in nine patients showed complete (n=3D7) or partial (n=3D2) resolution of parenchymal lesions. Chest radiographs of patients with simple pulmonary eosinophilia often reveal no abnormality. The most common finding is subtle opacity or nodule(s), while CT reveals transient nodule(s) with a surrounding halo or transient areas of ground glass opacity. (author)

  16. Radiologic findings of diffuse Pulmonary hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Mi Ra; Song, Koun Sik; Lee, Jin Seong; Lim, Tae Hwan [Ulsan Univ. College of Medicine, Seoul (Korea, Republic of)

    1998-12-01

    To describe the chest radiographic and CT findings of diffuse pulmonary hemorrhage. Two radiologists retrospectively analysed the chest radiographic and CT findings of six patients with diffuse pulmonary hemorrhage. Using open lung biopsy(n=3D2) and transbronchial lung biopsy or bronchoalveolar lavage(n=3D4), diagnosis was based on the presence of hemosiderin-laden macrophage or intra-alveolar hemorrhage. Underlying diseases were Wegener's granulomatosis(n=3D2), antiphospholipid antibody syndrome(n=3D2), Henoch-Schonlein purpura(n=3D1), and idopathic pulmonary hemosiderosis(n=3D1). In all patients, sequential chest radiographs, obtained during a one to six-month period, were available. HRCT scans were obtained in five patinets, and conventional CT scans in one. Follow-up HRCT scans were obtained in two. We also analyzed the patterns of involvement, distribution and sequential changes in the pulmonary abnormalities seen on chest radiographs and CT scans. Chest radiographs showed multifocal patchy consolidation(n=3D6), ground-glass opacity(n=3D3), and multiple granular or nodular opacity(n=3D3). These lesions were intermingled in five patients, while in one there was consolidation only. Sequential chest radiographs demonstrated the improvement of initial pulmonary abnormalities and appearance of new lesions elsewhere within 5-6 days, though within 7-25 (average, 13) days, these had almost normalized. HRCT scans showed patchy consolidation(n=3D5), multiple patchy ground-glass opacity(n=3D5), or ill-defined air space nodules(n=3D4). These lesions were intermingled in five patients, and in one, ground-glass opacity only was noted. In two patients there were interlobular septal thickening and intalobular reticular opacity. The distribution of these abnormalities was almost always bilateral, diffuse with no zonal predominancy, and spared the apex of the lung and subpleural region were less affected. Although chest radiographic and CT findings of diffuse pulmonary

  17. Radiologic findings of diffuse Pulmonary hemorrhage

    International Nuclear Information System (INIS)

    Seo, Mi Ra; Song, Koun Sik; Lee, Jin Seong; Lim, Tae Hwan

    1998-01-01

    To describe the chest radiographic and CT findings of diffuse pulmonary hemorrhage. Two radiologists retrospectively analysed the chest radiographic and CT findings of six patients with diffuse pulmonary hemorrhage. Using open lung biopsy(n=3D2) and transbronchial lung biopsy or bronchoalveolar lavage(n=3D4), diagnosis was based on the presence of hemosiderin-laden macrophage or intra-alveolar hemorrhage. Underlying diseases were Wegener's granulomatosis(n=3D2), antiphospholipid antibody syndrome(n=3D2), Henoch-Schonlein purpura(n=3D1), and idopathic pulmonary hemosiderosis(n=3D1). In all patients, sequential chest radiographs, obtained during a one to six-month period, were available. HRCT scans were obtained in five patinets, and conventional CT scans in one. Follow-up HRCT scans were obtained in two. We also analyzed the patterns of involvement, distribution and sequential changes in the pulmonary abnormalities seen on chest radiographs and CT scans. Chest radiographs showed multifocal patchy consolidation(n=3D6), ground-glass opacity(n=3D3), and multiple granular or nodular opacity(n=3D3). These lesions were intermingled in five patients, while in one there was consolidation only. Sequential chest radiographs demonstrated the improvement of initial pulmonary abnormalities and appearance of new lesions elsewhere within 5-6 days, though within 7-25 (average, 13) days, these had almost normalized. HRCT scans showed patchy consolidation(n=3D5), multiple patchy ground-glass opacity(n=3D5), or ill-defined air space nodules(n=3D4). These lesions were intermingled in five patients, and in one, ground-glass opacity only was noted. In two patients there were interlobular septal thickening and intalobular reticular opacity. The distribution of these abnormalities was almost always bilateral, diffuse with no zonal predominancy, and spared the apex of the lung and subpleural region were less affected. Although chest radiographic and CT findings of diffuse pulmonary

  18. Some properties of matter at very HTGH temperatures and high pressures (equations of state, opacity); Quelques proprietes de la matiere aux tres hautes temperatures et fortes pressions (equation d'etat, opacite)

    Energy Technology Data Exchange (ETDEWEB)

    Gervat, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-06-15

    The Thomas-Fermi equations which' are zero-order approximations of the Hartree-Fock equations, make it possible to study some aspects of the behaviour of matter at high pressures. In the first chapter is considered the calculation of 1 values which do not require the Schroedinger equation to be solved. The values of the quantum and exchange corrections give the zone of validity of the theory. For each R and T pair it is possible to calculate the energy and the pressure. For the calculation of the energy 'it has been necessary, in the region close to the nucleus where the corrections diverge, to replace the density given by the Thomas-Fermi theory by that deduced from the wave-functions which, in the small region, are very similar to that of a hydrogen atom of charge z. The calculation of the degree of ionization is particularly simple and does not require the Saha equations to be solved. Besides the distribution of electrons in the r space it is simple to determine the distribution according to the quantum number I, and this for each value of the R, T pair. In the second chapter, the introduction of the, Thomas and Fermi potential into the Schroedinger equation makes it possible to obtain the energy spectrum of a perfect isolated atom supposed to represent an average atom of the hot, compressed matter. The changes in the levels with increasing temperature and pressure can be deduced from this. It is particular easy with this model to interpret the phenomenon of ionization caused by pressure. A knowledge of the wave functions makes it possible to calculate the transition probabilities which, coupled with the occupation probabilities, lead to the opacity coefficients. Only the bound-free and free-free transitions have been considered but these latter include, because of the properties of the model used, a large part of bound-bound or band-band transitions. Finally, the use of the Thomas-Fermi potential for the calculation of bands is particularly suitable for

  19. April 2014 imaging case of the month

    Directory of Open Access Journals (Sweden)

    Eric A. Jensen

    2014-04-01

    Full Text Available No abstract available. Article truncated after first page. Clinical History: A 34-year-old woman presented with complaints of abdominal fullness. The patient described a history of several pneumonias, successfully treated with antibiotics. Liver function testing showed a mild transaminitis. Frontal chest radiography (Figure 1 was performed. Which of the following statements regarding the chest radiograph is most accurate? 1. The chest radiograph shows multifocal coarse linear opacities suggesting bronchiectasis; 2. The chest radiograph shows multifocal ground-glass opacity and consolidation; 3. The chest radiograph shows multifocal, somewhat basal predominant linear opacities within diminished lung volumes, suggesting fibrosis; 4. The chest radiograph shows multiple small nodules, suggesting a miliary pattern; 5. The chest radiograph shows symmetric, basal predominant fine linear and reticular abnormalities without architectural distortion...

  20. Increased fluoro-deoxy-D-glucose uptake on positron emission tomography-computed tomography postbronchoalveolar lavage: a potential cause of radiologic misinterpretation.

    LENUS (Irish Health Repository)

    Leong, Sum

    2011-08-01

    Cytologic analysis of bronchoalveolar lavage (BAL) fluid is used for lung cancer diagnosis. We describe a patient with a history of rectal carcinoma who presented with a new lung mass. BAL was performed, with positron emission tomography-computed tomography the following day. There was mildly increased fluoro-deoxy-D-glucose uptake in areas of the lung parenchyma with new ground-glass opacification. This created ambiguity in staging, clarified 2 weeks later by a computed tomography showing complete resolution of the ground-glass opacity. Clinicians should be aware that BAL may cause increased pulmonary fluoro-deoxy-D-glucose uptake, making accurate radiologic interpretation problematic. We suggest that to optimize positron emission tomography-computed tomography, studies should not be performed within 24 hours of BAL.

  1. Effect of radiation dose and iterative reconstruction on lung lesion conspicuity at MDCT: Does one size fit all?

    Energy Technology Data Exchange (ETDEWEB)

    Botelho, Marcos Paulo Ferreira; Agrawal, Rishi, E-mail: rishi.agrawal@northwestern.edu; Gonzalez-Guindalini, Fernanda Dias; Hart, Eric M.; Patel, Suresh K.; Töre, Hüseyin Gürkan; Yaghmai, Vahid

    2013-11-01

    Objective: To evaluate the effect of different acquisition parameters and reconstruction algorithms in lung lesions conspicuity in chest MDCT. Methods: An anthropomorphic chest phantom containing 6 models of lung disease (ground glass opacity, bronchial polyp, solid nodule, ground glass nodule, emphysema and tree-in-bud) was scanned using 80, 100 and 120 kVp, with fixed mAs ranging from 10 to 110. The scans were reconstructed using filtered back projection (FBP) and iterative reconstruction (IR) algorithms. Three blinded thoracic radiologists reviewed the images and scored lesions conspicuity and overall image quality. Image noise and radiation dose parameters were recorded. Results: All acquisitions with 120 kVp received a score of 3 (acceptable) or higher for overall image quality. There was no significant difference between IR and FBP within each setting for overall image quality (p > 0.05), even though image noise was significantly lower using IR (p < 0.0001). When comparing specific lower radiation acquisition parameters 100 kVp/10 mAs [Effective Dose (ED): 0.238 mSv] vs 120 kVp/10 mAs (ED: 0.406 mSv) vs 80 kVp/40 mAs (ED: 0.434 mSv), we observed significant difference in lesions conspicuity (p < 0.02), as well as significant difference in overall image quality, independent of the reconstruction algorithm (p < 0.02), with higher scores on the 120 kV/10 mAs setting. Tree-in-bud pattern, ground glass nodule and ground glass opacity required lower radiation doses to get a diagnostic score using IR when compared to FBP. Conclusion: Designing protocols for specific lung pathologies using lower dose acquisition parameters is feasible, and by applying iterative reconstruction, radiologists may have better diagnostic confidence to evaluate some lesions in very low dose settings, preserving acceptable image quality.

  2. 18F-FDG PET/CT 结合 HRCT 对肺微浸润性腺癌的诊断价值%Diagnostic value of combined 18 F-FDG PET/CT and HRCT for minimally invasive pulmonary adenocarcinoma

    Institute of Scientific and Technical Information of China (English)

    彭辽河; 胡晓燕; 周旋; 邱大胜; 李杰

    2014-01-01

    -ses ,10 had ground glass opacity (GGO) changes ,17 exhibited mixed nodules with GGO changes around the lesions ,and 1 case presented with solid nodules .HRCT showed that the lesions were showing lobulation in 18 cases (64 .3% ) ,spicu-lation in 20 cases (71 .4% ) ,vacuolar changes or air bronchogram in 21 cases (75% ) ,pleural indentation in 12 cases (42.9% ) ,vascular convergence in 10 cases (35 .7% ) ,and round nodule in 13 cases (46 .4% ) .The diagnostic accuracy of PET/CT ,HRCT ,and combined PET/CT and HRCT for MIA was 71 .4% ,82 .1% and 96 .4% respectively .Conclusion The false negative rate and the misdiagnosis rate were high in the diagnosis of MIA with routine PET /CT imaging .Combi-ning 18 F-FDG PET/CT with HRCT was reasonable and practicable ,which had synergistic effect in diagnosing MIA and could greatly improve the diagnostic accuracy .

  3. Pulmonary candidiasis after hematopoietic stem cell transplantation: thin-section CT findings.

    Science.gov (United States)

    Franquet, Tomás; Müller, Nestor L; Lee, Kyung S; Oikonomou, Anastasia; Flint, Julia D

    2005-07-01

    To retrospectively evaluate thin-section computed tomographic (CT) findings in hematopoietic stem cell transplant (ie, bone marrow transplant) patients with histopathologically proved pulmonary candidiasis. Ethical approval was obtained from the institutional review board of each of the three institutions; informed consent was not required. The study included 17 hematopoietic stem cell transplant recipients with proved pulmonary candidiasis. Histopathologic specimens were acquired at transbronchial biopsy (n = 8), open lung biopsy (n = 6), and autopsy (n = 3). The patients included seven men and 10 women (age range, 20-62 years; mean age, 37 years). The thin-section CT scans were retrospectively reviewed by two thoracic radiologists for the presence, appearance, and distribution of parenchymal abnormalities. Multiple nodules were present in 15 (88%) patients, including centrilobular nodules and tree-in-bud pattern in seven (41%) patients. Nodules were bilateral in 12 patients and unilateral in three. An associated halo of ground-glass opacity was identified in five (33%) patients. Nodules were the only CT finding in five patients (29%). Areas of air-space consolidation were identified in 11 (65%) patients. Areas of ground-glass opacity were seen in six (35%) of 17 patients and were always associated with other abnormalities. Other less common CT findings included pleural effusion (n = 3), thickening of the bronchial walls (n = 2), and cavitation (n = 1). The most common thin-section CT findings of pulmonary candidiasis in hematopoietic stem cell transplant patients are multiple bilateral nodular opacities often associated with areas of consolidation. Copyright RSNA, 2005

  4. Pneumocystis Pneumonia Presenting as an Enlarging Solitary Pulmonary Nodule

    Directory of Open Access Journals (Sweden)

    Krunal Bharat Patel

    2016-01-01

    Full Text Available Pneumocystis pneumonia is a life threatening infection that usually presents with diffuse bilateral ground-glass infiltrates in immunocompromised patients. We report a case of a single nodular granulomatous Pneumocystis pneumonia in a male with diffuse large B-cell lymphoma after R-CHOP therapy. He presented with symptoms of productive cough, dyspnea, and right-sided pleuritic chest pain that failed to resolve despite treatment with multiple antibiotics. Chest X-ray revealed right lower lobe atelectasis and CT of chest showed development of 2 cm nodular opacity with ground-glass opacities. Patient underwent bronchoscopy and biopsy that revealed granulomatous inflammation in a background of organizing pneumonia pattern with negative cultures. Respiratory symptoms resolved but the solitary nodular opacity increased in size prompting a surgical wedge resection which revealed granulomatous Pneumocystis pneumonia infection. This case is the third documented report of Pneumocystis pneumonia infection within a solitary pulmonary nodule in an individual with hematologic neoplasm. Although Pneumocystis pneumonia most commonly occurs in patients with HIV/acquired immunodeficiency syndrome and with diffuse infiltrates, the diagnosis should not be overlooked when only a solitary nodule is present.

  5. Active disease and residual damage in treated Wegener's granulomatosis: an observational study using pulmonary high-resolution computed tomography

    International Nuclear Information System (INIS)

    Komocsi, Andras; Reuter, Michael; Heller, Martin; Murakoezi, Henriette; Gross, Wolfgang L.; Schnabel, Armin

    2003-01-01

    The purpose of this study was to determine to what extent high-resolution computed tomography (HRCT) of the lungs can distinguish active inflammatory disease from inactive cicatricial disease in patients treated for Wegener's granulomatosis (WG). Twenty-eight WG patients with active pulmonary disease underwent a first HRCT examination immediately before standard immunosuppressive treatment and a second examination after clinical remission had been achieved. Lesions remaining after treatment were categorized as residual damage and were compared with findings during active disease to see by what features active and cicatricial disease can be distinguished. During active disease 17 patients had nodules/masses, 12 had ground-glass opacities, 6 had septal lines and 6 had non-septal lines. After treatment, ground-glass opacities had resolved completely. Nodules/masses had resolved in 8 patients and had diminished in 7 patients. Residual nodules were distinguished from nodules/masses in active disease by lack of cavitation and a diameter of mostly <15 mm. In one-third of patients lines resolved, but in 8 instances new lines evolved during immunosuppression. During a follow-up period of a median 26.5 months (range 20.0-33.8), patients with residual nodules or lines had no more relapses than patients with completely cleared lungs. Treated pulmonary WG leaves substantial residual damage. High-resolution CT does assist in the distinction between active and inactive lesions. Ground-glass opacities, cavitating nodules/masses and masses measuring more than 3 cm represent active disease ordinarily. Non-cavitary small nodules and septal or non-septal lines can be either active or cicatricial lesions. The nature of these lesions needs to be clarified by longitudinal observation. (orig.)

  6. High-resolution computed tomography findings from adult patients with Influenza A (H1N1) virus-associated pneumonia

    International Nuclear Information System (INIS)

    Marchiori, Edson; Zanetti, Glaucia; Hochhegger, Bruno; Rodrigues, Rosana Souza; Fontes, Cristina Asvolinsque Pantaleao; Nobre, Luiz Felipe; Dias Mancano, Alexandre; Meirelles, Gustavo; Irion, Klaus Loureiro

    2010-01-01

    Objective: The aim of this study was to assess the high-resolution computed tomography (HRCT) findings at presentation in patients diagnosed with Influenza A (H1N1) virus-associated pneumonia. Materials and methods: We reviewed the HRCT findings from 20 patients diagnosed with Influenza A (H1N1) and compared their HRCT scans with chest radiographs, obtained on the same day. The imaging studies were obtained 4-9 days after the onset of symptoms. The patients included 11 men and 9 women (ages 24-62 years; mean 42.7 years). All patients had a body temperature greater than 100.4 deg. F (>38 deg. C), tachypnea, and cough. Other common symptoms included diarrhea (60%) and sore throat (30%). The radiographs and HRCT scans were reviewed independently by two observers who reached a consensus decision. Results: The predominant HRCT findings consisted of bilateral ground-glass opacities (n = 12), bilateral areas of consolidation (n = 2), or a mixed bilateral pattern of ground-glass opacities and areas of consolidation (n = 6). The abnormalities were bilateral in all of the 20 patients, had a predominantly sub-pleural distribution in 13 patients, and had a random distribution in the remaining 7 patients. The predominant radiographic findings were consolidations. Normal radiographs were found in 4 out of the 20 patients. Conclusion: HRCT may reveal parenchymal abnormalities in patients with Influenza A (H1N1) infection who have normal findings on radiographs. The predominant HRCT findings were bilateral, peripheral, ground-glass opacities and/or bilateral areas of consolidation. The patients who presented consolidations had more severe clinical course.

  7. CT and pathologic correlation acute miliary pulmonary tuberculosis

    International Nuclear Information System (INIS)

    Yang Jing; Ma Daqing; Zhang Yansong; Guan Yansheng; Yang Jun; Liu Weihua

    2011-01-01

    Objective: To elucidate the CT characteristics and pathology of acute miliary pulmonary tuberculosis (AMPT). Methods: The CT features of AMPT in 25 cases were analyzed retrospectively, and the CT features in HIV-seronegative and HIV-seropositive patients were compared by 2-sided exact probability Chi-square test. Two lung specimens were inflated and fixed by Heitzman's method. HRCT scans, gross specimen section (80-150 μm) and histologic section (5 μm) were performed on dry lung specimens and CT-pathologic correlation was conducted. The distribution of micronodules in the secondary lobule on HRCT and pathology in one specimen was evaluated by Chi-square test. Results: Twenty five patients with AMPT were included in this study, including 11 HIV-seropositive patients and 14 HIV- seronegative patients. HRCT showed diffuse micronodules randomly distributed throughout both lungs in 25 patients, and ground-glass opacity (17 patients) was the predominant complicated finding. Coalescence of nodules and consolidation in HIV-seropositive patients (5 and 6 patients) were markedly higher than that in HIV-seronegative patients (none). In lung specimens, most nodules located in the lung parenchyma between the central bronchovascular bundle and the perilobular structures (792 and 560 nodules), which located in the interlobular septum pathologically. The distribution of micronodules in the secondary lobule showed on HRCT (1060 nodules) and pathology (864 nodules) was not significantly difference (χ 2 =2.814, P>0.05) . HRCT showed ground-glass opacities when ARDS occurred, which were pulmonary edema, inflammation and hyaline membrane on alveolar wall pathologically. Conclusions: The HRCT characteristic of nodule distribution in AMPT is random. ARDS should be suspected when diffuse ground-glass opacities appear on HRCT. (authors)

  8. Surgical resection of highly suspicious pulmonary nodules without a tissue diagnosis

    International Nuclear Information System (INIS)

    Heo, Eun-Young; Lee, Kyung-Won; Jheon, Sanghoon; Lee, Jae-Ho; Lee, Choon-Taek; Yoon, Ho-II

    2011-01-01

    The safety and efficacy of surgical resection of lung nodule without tissue diagnosis is controversial. We evaluated direct surgical resection of highly suspicious pulmonary nodules and the clinical and radiological predictors of malignancy. Retrospective analyses were performed on 113 patients who underwent surgical resection without prior tissue diagnosis for highly suspicious pulmonary nodules. Clinical and radiological characteristics were compared between histologically proven benign and malignant nodules after resection. Total costs, length of hospitalization and waiting time to surgery were compared with those of patients who had tissue diagnosis prior to surgery. Among 280 patients with pulmonary nodules suspicious for lung cancer, 113 (40.4%) underwent operation without prior tissue diagnosis. Lung nodules were diagnosed as malignant in 96 (85%) of the 113 patients. Except for forced expiratory volume in 1 s, clinical characteristics were not significantly different according to the pathologic results. Forty-five (90%) of 50 patients with ground-glass opacity nodules had a malignancy. Mixed ground-glass opacity, bubble lucency, irregular margin and larger size correlated with malignancy in ground-glass opacity nodules (P<0.05). Fifty-one (81%) of 67 patients with solid nodules had a malignancy. Spiculation, pre-contrast attenuation and contrast enhancement significantly correlated with malignancy in solid nodules (P<0.05). Surgical resection without tissue diagnosis significantly decreased total costs, hospital stay and waiting time (P<0.05). Direct surgical resection of highly suspicious pulmonary nodules can be a valid procedure. However, careful patient selection and further investigations are required to justify direct surgical resection. (author)

  9. Finding of CT and clinical in paraquat poisoning pulmonary injury

    International Nuclear Information System (INIS)

    He Zaifang; Li Hongbing; Cheng Shoulin; Li Qixiang; Huang Zhen; Zeng Jianguo

    2012-01-01

    Objective: To investigate the CT features of pulmonary injury in paraquat poisoning. Methods: The chest CT image of lung injury in 6 cases of paraquat poisoning were analyzed retrospectively. According to different period of poisoning, the 6 cases were divided into 3 types:the early stage of poisoning (within 2 d), the middle stage of poisoning (3-14 d), the late stage of poisoning (>14 d). A comparison between CT signs and the pathological features of patients was made. Results: Among this 6 cases, 3 cases died, 2 cases pulmonary fibrosis was noted, 1 cases recovered. According to different period of poisoning, the 6 cases were divided into 3 stages: in the early stage of poisoning (within 2 d), 3 cases of all patients showed nothing remarkable, 2 cases showed ground-glass opacity, 1 case showed fuzzy lung-marking.In the middle stage of poisoning (3-14 d), all 6 cases showed ground-glass opacity, mosaic attenuation; 6 cases showed pulmonary consolidation; 4 cases showed subpleural lines; 4 cases showed bronchiectasis; 2 cases showed mid-lower pleural effusion. In the late stage of poisoning (>14 d), 4 cases showed pulmonary consolidation and pulmonary fibrosis, 3 cases showed ground-glass opacity and mosaic attenuation, 1 case showed mid-lower pleural effusion; 1 case showed mediastinal emphysema. Conclusion: The clinical pathology process of paraquat poisoning was in line with CT finding which was related with clinical stage and was helpful for clinical assessment of paraquat poisoning promptly and to guide the clinical treatment. (authors)

  10. High-resolution computed tomography findings from adult patients with Influenza A (H1N1) virus-associated pneumonia

    Energy Technology Data Exchange (ETDEWEB)

    Marchiori, Edson [Fluminense Federal University, Rio de Janeiro (Brazil); Federal University of Rio de Janeiro, Rio de Janeiro (Brazil)], E-mail: edmarchiori@gmail.com; Zanetti, Glaucia [Federal University of Rio de Janeiro, Rio de Janeiro (Brazil)], E-mail: glauciazanetti@gmail.com; Hochhegger, Bruno [Federal University of Rio de Janeiro, Rio de Janeiro (Brazil)], E-mail: brunohochhegger@gmail.com; Rodrigues, Rosana Souza [Federal University of Rio de Janeiro, Rio de Janeiro (Brazil); D' OR Institute for Research and Education, Rio de Janeiro (Brazil)], E-mail: rosana.souzarodrigues@gmail.com; Fontes, Cristina Asvolinsque Pantaleao [Fluminense Federal University, Rio de Janeiro (Brazil)], E-mail: cristinasvolinsque@gmail.com; Nobre, Luiz Felipe [Santa Catarina Federal University, Florianopolis (Brazil)], E-mail: luizfelipenobresc@gmail.com; Dias Mancano, Alexandre [Anchieta Hospital, Taguatinga, DF (Brazil)], E-mail: alex.manzano1@gmail.com; Meirelles, Gustavo [Sao Paulo Federal University, Sao Paulo (Brazil)], E-mail: gmeirelles@gmail.com; Irion, Klaus Loureiro [Liverpool Heart and Chest Hospital NHS Trust, Liverpool (United Kingdom); Royal Liverpool and Broadgreen University Hospital NHS, Liverpool (United Kingdom)], E-mail: klaus.irion@btinternet.com

    2010-04-15

    Objective: The aim of this study was to assess the high-resolution computed tomography (HRCT) findings at presentation in patients diagnosed with Influenza A (H1N1) virus-associated pneumonia. Materials and methods: We reviewed the HRCT findings from 20 patients diagnosed with Influenza A (H1N1) and compared their HRCT scans with chest radiographs, obtained on the same day. The imaging studies were obtained 4-9 days after the onset of symptoms. The patients included 11 men and 9 women (ages 24-62 years; mean 42.7 years). All patients had a body temperature greater than 100.4 deg. F (>38 deg. C), tachypnea, and cough. Other common symptoms included diarrhea (60%) and sore throat (30%). The radiographs and HRCT scans were reviewed independently by two observers who reached a consensus decision. Results: The predominant HRCT findings consisted of bilateral ground-glass opacities (n = 12), bilateral areas of consolidation (n = 2), or a mixed bilateral pattern of ground-glass opacities and areas of consolidation (n = 6). The abnormalities were bilateral in all of the 20 patients, had a predominantly sub-pleural distribution in 13 patients, and had a random distribution in the remaining 7 patients. The predominant radiographic findings were consolidations. Normal radiographs were found in 4 out of the 20 patients. Conclusion: HRCT may reveal parenchymal abnormalities in patients with Influenza A (H1N1) infection who have normal findings on radiographs. The predominant HRCT findings were bilateral, peripheral, ground-glass opacities and/or bilateral areas of consolidation. The patients who presented consolidations had more severe clinical course.

  11. 3 Tesla proton MRI for the diagnosis of pneumonia/lung infiltrates in neutropenic patients with acute myeloid leukemia: initial results in comparison to HRCT.

    Science.gov (United States)

    Attenberger, U I; Morelli, J N; Henzler, T; Buchheidt, D; Fink, C; Schoenberg, S O; Reichert, M

    2014-01-01

    To evaluate the diagnostic accuracy of 3 Tesla proton MRI for the assessment of pneumonia/lung infiltrates in neutropenic patients with acute myeloid leukemia. In a prospective study, 3 Tesla MRI was performed in 19 febrile neutropenic patients (5 women, 14 men; mean age 61 years ± 14.2; range 23-77 years). All patients underwent high-resolution CT less than 24h prior to MRI. The MRI protocol (Magnetom Tim Trio, Siemens) included a T2-weighted HASTE sequence (TE/TR: 49 ms/∞, slice thickness 6mm) and a high-resolution 3D VIBE sequence with an ultra-short TETesla MRI with a sensitivity of 82.3% and a specificity of 78.6%, resulting in an overall accuracy of 88% (NPV/PPV 66.7%/89.5%). In 51 lobes (19 of 19 patients), pulmonary abnormalities visualized by MR were judged to be concordant in their location and in the lesion type identified by both readers. In 22 lobes (11 of 19 patients), no abnormalities were present on either MR or HRCT (true negative). In 6 lobes (5 of 19 patients), ground glass opacity areas were detected on MRI but were not visible on HRCT (false positives). In 11 lobes (7 of 19 patients), MRI failed to detect ground glass opacity areas identified by HRCT. However, since the abnormalities were disseminated in these patients, accurate treatment decisions were possible in every case based on MRI. In one case MRI showed a central area of cavitation, which was not visualized by HRCT. Infectious nodules and consolidations can be detected in neutropenic patients with acute myeloid leukemia with a sufficient diagnostic accuracy by 3 Tesla MRI. Detection of ground glass opacity areas is the main limitation of 3-Tesla MRI when compared to HRCT. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  12. Pulmonary complications of crack cocaine use: high-resolution computed tomography of the chest

    International Nuclear Information System (INIS)

    Mancano, Alexandre

    2008-01-01

    Here, we report high-resolution computed tomography (HRCT) findings in a patient who developed sudden hemoptysis, dyspnea and chest pain after smoking crack cocaine. Chest X-rays showed consolidations, primarily in the upper lobes, and HRCT scans showed ground glass attenuation opacities, consolidations and air-space nodules. A follow-up CT, after drug use discontinuation and administration of corticosteroids, showed partial resolution of pulmonary lesions and the appearance of cavitations. Clinical, imaging and laboratory findings led to a diagnosis of 'crack lung'. (author)